Robust, Adaptive Radar Detection and Estimation
2015-07-21
cost function is not a convex function in R, we apply a transformation variables i.e., let X = σ2R−1 and S′ = 1 σ2 S. Then, the revised cost function in...1 viv H i . We apply this inverse covariance matrix in computing the SINR as well as estimator variance. • Rank Constrained Maximum Likelihood: Our...even as almost all available training samples are corrupted. Probability of Detection vs. SNR We apply three test statistics, the normalized matched
Wang, Zhao; Lee, Hsiang-Chieh; Vermeulen, Diedrik; Chen, Long; Nielsen, Torben; Park, Seo Yeon; Ghaemi, Allan; Swanson, Eric; Doerr, Chris; Fujimoto, James
2015-07-01
Optical coherence tomography (OCT) is a widely used three-dimensional (3D) optical imaging method with many biomedical and non-medical applications. Miniaturization, cost reduction, and increased functionality of OCT systems will be critical for future emerging clinical applications. We present a silicon photonic integrated circuit swept-source OCT (SS-OCT) coherent receiver with dual polarization, dual balanced, in-phase and quadrature (IQ) detection. We demonstrate multiple functional capabilities of IQ polarization resolved detection including: complex-conjugate suppressed full-range OCT, polarization diversity detection, and polarization-sensitive OCT. To our knowledge, this is the first demonstration of a silicon photonic integrated receiver for OCT. The integrated coherent receiver provides a miniaturized, low-cost solution for SS-OCT, and is also a key step towards a fully integrated high speed SS-OCT system with good performance and multi-functional capabilities. With further performance improvement and cost reduction, photonic integrated technology promises to greatly increase penetration of OCT systems in existing applications and enable new applications.
Wang, Zhao; Lee, Hsiang-Chieh; Vermeulen, Diedrik; Chen, Long; Nielsen, Torben; Park, Seo Yeon; Ghaemi, Allan; Swanson, Eric; Doerr, Chris; Fujimoto, James
2015-01-01
Optical coherence tomography (OCT) is a widely used three-dimensional (3D) optical imaging method with many biomedical and non-medical applications. Miniaturization, cost reduction, and increased functionality of OCT systems will be critical for future emerging clinical applications. We present a silicon photonic integrated circuit swept-source OCT (SS-OCT) coherent receiver with dual polarization, dual balanced, in-phase and quadrature (IQ) detection. We demonstrate multiple functional capabilities of IQ polarization resolved detection including: complex-conjugate suppressed full-range OCT, polarization diversity detection, and polarization-sensitive OCT. To our knowledge, this is the first demonstration of a silicon photonic integrated receiver for OCT. The integrated coherent receiver provides a miniaturized, low-cost solution for SS-OCT, and is also a key step towards a fully integrated high speed SS-OCT system with good performance and multi-functional capabilities. With further performance improvement and cost reduction, photonic integrated technology promises to greatly increase penetration of OCT systems in existing applications and enable new applications. PMID:26203382
Using personal glucose meters and functional DNA sensors to quantify a variety of analytical targets
Xiang, Yu; Lu, Yi
2012-01-01
Portable, low-cost and quantitative detection of a broad range of targets at home and in the field has the potential to revolutionize medical diagnostics and environmental monitoring. Despite many years of research, very few such devices are commercially available. Taking advantage of the wide availability and low cost of the pocket-sized personal glucose meter—used worldwide by diabetes sufferers—we demonstrate a method to use such meters to quantify non-glucose targets, ranging from a recreational drug (cocaine, 3.4 μM detection limit) to an important biological cofactor (adenosine, 18 μM detection limit), to a disease marker (interferon-gamma of tuberculosis, 2.6 nM detection limit) and a toxic metal ion (uranium, 9.1 nM detection limit). The method is based on the target-induced release of invertase from a functional-DNA–invertase conjugate. The released invertase converts sucrose into glucose, which is detectable using the meter. The approach should be easily applicable to the detection of many other targets through the use of suitable functional-DNA partners (aptamers DNAzymes or aptazymes). PMID:21860458
Using personal glucose meters and functional DNA sensors to quantify a variety of analytical targets
NASA Astrophysics Data System (ADS)
Xiang, Yu; Lu, Yi
2011-09-01
Portable, low-cost and quantitative detection of a broad range of targets at home and in the field has the potential to revolutionize medical diagnostics and environmental monitoring. Despite many years of research, very few such devices are commercially available. Taking advantage of the wide availability and low cost of the pocket-sized personal glucose meter—used worldwide by diabetes sufferers—we demonstrate a method to use such meters to quantify non-glucose targets, ranging from a recreational drug (cocaine, 3.4 µM detection limit) to an important biological cofactor (adenosine, 18 µM detection limit), to a disease marker (interferon-gamma of tuberculosis, 2.6 nM detection limit) and a toxic metal ion (uranium, 9.1 nM detection limit). The method is based on the target-induced release of invertase from a functional-DNA-invertase conjugate. The released invertase converts sucrose into glucose, which is detectable using the meter. The approach should be easily applicable to the detection of many other targets through the use of suitable functional-DNA partners (aptamers, DNAzymes or aptazymes).
2006-05-15
alarm performance in a cost-effective manner is the use of track - before - detect strategies, in which multiple sensor detections must occur within the...corresponding to the traditional sensor coverage problem. Also, in the track - before - detect context, reference is made to the field-level functions of...detection and false alarm as successful search and false search, respectively, because the track - before - detect process serves as a searching function
Kraan, Tamar C; Ising, Helga K; Fokkema, Marjolein; Velthorst, Eva; van den Berg, David P G; Kerkhoven, Margot; Veling, Wim; Smit, Filip; Linszen, Don H; Nieman, Dorien H; Wunderink, Lex; Boonstra, Nynke; Klaassen, Rianne M C; Dragt, Sara; Rietdijk, Judith; de Haan, Lieuwe; van der Gaag, Mark
2017-01-01
Childhood adversity is associated with a range of mental disorders, functional impairment and higher health care costs in adulthood. In this study we evaluated if childhood adversity was predictive of adverse clinical and functional outcomes and health care costs in a sample of patients at ultra-high risk (UHR) for developing a psychosis. Structural Equation Modeling was used to examine the effect of childhood adversity on depression, anxiety, transition to psychosis and overall functioning at 4-year follow-up. In addition, we evaluated economic costs of childhood adversity in terms of health care use and productivity loss. Data pertain to 105 UHR participants of the Dutch Early Detection and Intervention Evaluation (EDIE-NL). Physical abuse was associated with higher depression rates (b=0.381, p=0.012) and lower social functional outcome (b=-0.219, p=0.017) at 4-year follow-up. In addition, emotional neglect was negatively associated with social functioning (b=-0.313, p=0.018). We did not find evidence that childhood adversity was associated with transition to psychosis, but the experience of childhood adversity was associated with excess health care costs at follow-up. The data indicate long-term negative effects of childhood adversity on depression, social functioning and health care costs at follow-up in a sample of UHR patients. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Moger, Tron A; Bjørnelv, Gudrun M W; Aas, Eline
2016-07-01
The shift towards earlier stages of disease advancement at diagnosis when introducing mammography screening is expected to affect the treatment costs of breast cancer. We collected data on hospital resource use in Norway following a breast cancer diagnosis for the period 1 January, 2008 through 31 December, 2009 for women aged 50-69 years, diagnosed with breast cancer during the period 1 January, 1999 through 31 December, 2009. We estimated treatment costs using a function that included the probability of being at risk for receiving treatment, estimated by means of the Cox proportional hazard model. In total, 16,045 patients were included for the analyses among which 10.5 % died during the study period. The mean 10-year per-person treatment cost was €31,940 (95 % CI €31,030-32,880), and lower for cancers detected within the public screening program (€30,730) than for those detected elsewhere (€36,230). For ductal carcinoma in situ (DCIS) and cancers in stages I thru IV, treatment costs were €15,740, €23,570, €46,550, €55,230 and €60,430, respectively. Interval cancers occurring within the screening program were generally more resource demanding than both cancers detected at screening or elsewhere. Ten-year treatment costs increased by increasing stage at diagnosis. Patients whose cancer was detected within the public screening program had lower treatment costs than those detected elsewhere. Interval cancers had higher costs than others.
DOT National Transportation Integrated Search
2013-10-01
This study will evaluate the video detection technologies currently adopted by the city : of Baton Rouge, LA, and DOTD with the purpose of establishing design guidelines based : on the detection needs, functionality, and cost. The study will also dev...
Trogdon, Justin G.; Subramanian, Sujha; Crouse, Wesley
2018-01-01
This study investigates the existence of economies of scale in the provision of breast and cervical cancer screening and diagnostic services by state National Breast and Cervical Cancer Early Detection Program (NBCCEDP) grantees. A translog cost function is estimated as a system with input factor share equations. The estimated cost function is then used to determine output levels for which average costs are decreasing (i.e., economies of scale exist). Data were collected from all state NBCCEDP programs and District of Columbia for program years 2006–2007, 2008–2009 and 2009–2010 (N =147). Costs included all programmatic and in-kind contributions from federal and non-federal sources, allocated to breast and cervical cancer screening activities. Output was measured by women served, women screened and cancers detected, separately by breast and cervical services for each measure. Inputs included labor, rent and utilities, clinical services, and quasi-fixed factors (e.g., percent of women eligible for screening by the NBCCEDP). 144 out of 147 program-years demonstrated significant economies of scale for women served and women screened; 136 out of 145 program-years displayed significant economies of scale for cancers detected. The cost data were self-reported by the NBCCEDP State programs. Quasi-fixed inputs were allowed to affect costs but not economies of scale or the share equations. The main analysis accounted for clustering of observations within State programs, but it did not make full use of the panel data. The average cost of providing breast and cervical cancer screening services decreases as the number of women screened and served increases. PMID:24326873
Cyber-Physical Attacks With Control Objectives
Chen, Yuan; Kar, Soummya; Moura, Jose M. F.
2017-08-18
This study studies attackers with control objectives against cyber-physical systems (CPSs). The goal of the attacker is to counteract the CPS's controller and move the system to a target state while evading detection. We formulate a cost function that reflects the attacker's goals, and, using dynamic programming, we show that the optimal attack strategy reduces to a linear feedback of the attacker's state estimate. By changing the parameters of the cost function, we show how an attacker can design optimal attacks to balance the control objective and the detection avoidance objective. In conclusion, we provide a numerical illustration based onmore » a remotely controlled helicopter under attack.« less
Cyber-Physical Attacks With Control Objectives
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, Yuan; Kar, Soummya; Moura, Jose M. F.
This study studies attackers with control objectives against cyber-physical systems (CPSs). The goal of the attacker is to counteract the CPS's controller and move the system to a target state while evading detection. We formulate a cost function that reflects the attacker's goals, and, using dynamic programming, we show that the optimal attack strategy reduces to a linear feedback of the attacker's state estimate. By changing the parameters of the cost function, we show how an attacker can design optimal attacks to balance the control objective and the detection avoidance objective. In conclusion, we provide a numerical illustration based onmore » a remotely controlled helicopter under attack.« less
Online Plagiarism Detection Services--Saviour or Scourge?
ERIC Educational Resources Information Center
McKeever, Lucy
2006-01-01
Although the exponential growth of the Internet has made it easier than ever to carry out plagiarism, it has also made it much easier to detect. This paper gives an overview of the many different methods of detecting web-based plagiarism which are currently available, assessing practical matters such as cost, functionality and performance.…
Tawara, Yuichi; Senjyu, Hideaki; Tanaka, Kenichiro; Tanaka, Takako; Asai, Masaharu; Kozu, Ryo; Tabusadani, Mitsuru; Honda, Sumihisa; Sawai, Terumitsu
2015-01-01
We established a COPD taskforce for early detection, diagnosis, treatment, and intervention. We implemented a pilot intervention with a prospective and longitudinal design in a regional city. This study evaluates the usefulness of the COPD taskforce and intervention based on COPD case detection rate and per capita medical costs. We distributed a questionnaire to all 8,878 inhabitants aged 50-89 years, resident in Matsuura, Nagasaki Prefecture in 2006. Potentially COPD-positive persons received a pulmonary function test and diagnosis. We implemented ongoing detection, examination, education, and treatment interventions, performed follow-up examinations or respiratory lessons yearly, and supported the health maintenance of each patient. We compared COPD medical costs in Matsuura and in the rest of Nagasaki Prefecture using data from 2004 to 2013 recorded by the association of Nagasaki National Health Insurance Organization, assessing 10-year means and annual change. As of 2014, 256 people have received a definitive diagnosis of COPD; representing 31% of the estimated total number of COPD patients. Of the cases detected, 87.5% were mild or moderate in severity. COPD medical costs per patient in Matsuura were significantly lower than the rest of Nagasaki Prefecture, as was rate of increase in cost over time. The COPD program in Matsuura enabled early detection and treatment of COPD patients and helped to lower the associated burden of medical costs. The success of this program suggests that a similar program could reduce the economic and human costs of COPD morbidity throughout Japan.
Functionalized multi-walled carbon nanotube based sensors for distributed methane leak detection
This paper presents a highly sensitive, energy efficient and low-cost distributed methane (CH4) sensor system (DMSS) for continuous monitoring, detection and localization of CH4 leaks in natural gas infrastructure such as transmission and distribution pipelines, wells, and produc...
Yebo, Nebiyu A; Sree, Sreeprasanth Pulinthanathu; Levrau, Elisabeth; Detavernier, Christophe; Hens, Zeger; Martens, Johan A; Baets, Roel
2012-05-21
Portable, low cost and real-time gas sensors have a considerable potential in various biomedical and industrial applications. For such applications, nano-photonic gas sensors based on standard silicon fabrication technology offer attractive opportunities. Deposition of high surface area nano-porous coatings on silicon photonic sensors is a means to achieve selective, highly sensitive and multiplexed gas detection on an optical chip. Here we demonstrate selective and reversible ammonia gas detection with functionalized silicon-on-insulator optical micro-ring resonators. The micro-ring resonators are coated with acidic nano-porous aluminosilicate films for specific ammonia sensing, which results in a reversible response to NH(3)with selectivity relative to CO(2). The ammonia detection limit is estimated at about 5 ppm. The detectors reach a steady response to NH(3) within 30 and return to their base level within 60 to 90 seconds. The work opens perspectives on development of nano-photonic sensors for real-time, non-invasive, low cost and light weight biomedical and industrial sensing applications.
Chai, Ying; Tian, Dayong; Wang, Wei; Cui, Hua
2010-10-28
Luminol functionalized gold nanoparticles were used as labels for electrochemiluminescence signal amplification and an ultrasensitive, highly selective, convenient, low cost DNA detection strategy was developed.
van den Bosch, Frank; Gottwald, Timothy R.; Alonso Chavez, Vasthi
2017-01-01
The spread of pathogens into new environments poses a considerable threat to human, animal, and plant health, and by extension, human and animal wellbeing, ecosystem function, and agricultural productivity, worldwide. Early detection through effective surveillance is a key strategy to reduce the risk of their establishment. Whilst it is well established that statistical and economic considerations are of vital importance when planning surveillance efforts, it is also important to consider epidemiological characteristics of the pathogen in question—including heterogeneities within the epidemiological system itself. One of the most pronounced realisations of this heterogeneity is seen in the case of vector-borne pathogens, which spread between ‘hosts’ and ‘vectors’—with each group possessing distinct epidemiological characteristics. As a result, an important question when planning surveillance for emerging vector-borne pathogens is where to place sampling resources in order to detect the pathogen as early as possible. We answer this question by developing a statistical function which describes the probability distributions of the prevalences of infection at first detection in both hosts and vectors. We also show how this method can be adapted in order to maximise the probability of early detection of an emerging pathogen within imposed sample size and/or cost constraints, and demonstrate its application using two simple models of vector-borne citrus pathogens. Under the assumption of a linear cost function, we find that sampling costs are generally minimised when either hosts or vectors, but not both, are sampled. PMID:28846676
Scalable Low-Cost Fabrication of Disposable Paper Sensors for DNA Detection
2015-01-01
Controlled integration of features that enhance the analytical performance of a sensor chip is a challenging task in the development of paper sensors. A critical issue in the fabrication of low-cost biosensor chips is the activation of the device surface in a reliable and controllable manner compatible with large-scale production. Here, we report stable, well-adherent, and repeatable site-selective deposition of bioreactive amine functionalities and biorepellant polyethylene glycol-like (PEG) functionalities on paper sensors by aerosol-assisted, atmospheric-pressure, plasma-enhanced chemical vapor deposition. This approach requires only 20 s of deposition time, compared to previous reports on cellulose functionalization, which takes hours. A detailed analysis of the near-edge X-ray absorption fine structure (NEXAFS) and its sensitivity to the local electronic structure of the carbon and nitrogen functionalities. σ*, π*, and Rydberg transitions in C and N K-edges are presented. Application of the plasma-processed paper sensors in DNA detection is also demonstrated. PMID:25423585
Scalable Low-Cost Fabrication of Disposable Paper Sensors for DNA Detection
Gandhiraman, Ram P.; Nordlund, Dennis; Jayan, Vivek; ...
2014-11-25
Controlled integration of features that enhance the analytical performance of a sensor chip is a challenging task in the development of paper sensors. A critical issue in the fabrication of low-cost biosensor chips is the activation of the device surface in a reliable and controllable manner compatible with large-scale production. Here, we report stable, well-adherent, and repeatable site-selective deposition of bioreactive amine functionalities and biorepellant polyethylene glycol-like (PEG) functionalities on paper sensors by aerosol-assisted, atmospheric-pressure, plasma-enhanced chemical vapor deposition. This approach requires only 20 s of deposition time, compared to previous reports on cellulose functionalization, which takes hours. We presentmore » a detailed analysis of the near-edge X-ray absorption fine structure (NEXAFS) and its sensitivity to the local electronic structure of the carbon and nitrogen functionalities. σ*, π*, and Rydberg transitions in C and N K-edges. Lastly, application of the plasma-processed paper sensors in DNA detection is also demonstrated.« less
Low Cost Night Vision System for Intruder Detection
NASA Astrophysics Data System (ADS)
Ng, Liang S.; Yusoff, Wan Azhar Wan; R, Dhinesh; Sak, J. S.
2016-02-01
The growth in production of Android devices has resulted in greater functionalities as well as lower costs. This has made previously more expensive systems such as night vision affordable for more businesses and end users. We designed and implemented robust and low cost night vision systems based on red-green-blue (RGB) colour histogram for a static camera as well as a camera on an unmanned aerial vehicle (UAV), using OpenCV library on Intel compatible notebook computers, running Ubuntu Linux operating system, with less than 8GB of RAM. They were tested against human intruders under low light conditions (indoor, outdoor, night time) and were shown to have successfully detected the intruders.
Recent Advances for the Detection of Ochratoxin A.
Ha, Tai Hwan
2015-12-04
Ochratoxin A (OTA) is one of the mycotoxins secreted by Aspersillus and Penicillium that can easily colonize various grains like coffee, peanut, rice, and maize. Since OTA is a chemically stable compound that can endure the physicochemical conditions of modern food processing, additional research efforts have been devoted to develop sensitive and cost-effective surveillance solutions. Although traditional chromatographic and immunoassays appear to be mature enough to attain sensitivity up to the regulation levels, alternative detection schemes are still being enthusiastically pursued in an attempt to meet the requirements of rapid and cost-effective detections. Herein, this review presents recent progresses in OTA detections with minimal instrumental usage, which have been facilitated by the development of OTA aptamers and by the innovations in functional nanomaterials. In addition to the introduction of aptamer-based OTA detection techniques, OTA-specific detection principles are also presented, which exclusively take advantage of the unique chemical structure and related physicochemical characteristics.
NASA Astrophysics Data System (ADS)
Sando, Shota; Zhang, Bo; Cui, Tianhong
2017-12-01
Combination of shrink induced nano-composites technique and layer-by-layer (LbL) self-assembled graphene challenges controlling surface morphology. Adjusting shrink temperature achieves tunability on graphene surface morphology on shape memory polymers, and it promises to be an alternative in fields of high-surface-area conductors and molecular detection. In this study, self-assembled graphene on a shrink polymer substrate exhibits nanowrinkles after heating. Induced nanowrinkles on graphene with different shrink temperature shows distinct surface roughness and wettability. As a result, it becomes more hydrophilic with higher shrink temperatures. The tunable wettability promises to be utilized in, for example, microfluidic devices. The graphene on shrink polymer also exhibits capability of being used in sensing applications for pH and alpha-fetoprotein (AFP) detection with advantages of label free and low cost, due to self-assembly technique, easy functionalization, and antigen-antibody reaction on graphene surface. The detection limit of AFP detection is down to 1 pg/mL, and therefore the sensor also has a significant potential for biosensing as it relies on low-cost self-assembly and label-free assay.
Humayun, Md Tanim; Divan, Ralu; Stan, Liliana; ...
2016-06-16
This paper presents a highly sensitive, energy efficient and low-cost distributed methane (CH 4) sensor system (DMSS) for continuous monitoring, detection, and localization of CH 4 leaks in natural gas infrastructure, such as transmission and distribution pipelines, wells, and production pads. The CH 4 sensing element, a key component of the DMSS, consists of a metal oxide nanocrystal (MONC) functionalized multi-walled carbon nanotube (MWCNT) mesh which, in comparison to existing literature, shows stronger relative resistance change while interacting with lower parts per million (ppm) concentration of CH 4. A Gaussian plume triangulation algorithm has been developed for the DMSS. Givenmore » a geometric model of the surrounding environment the algorithm can precisely detect and localize a CH 4 leak as well as estimate its mass emission rate. A UV-based surface recovery technique making the sensor recover 10 times faster than the reported ones is presented for the DMSS. In conclusion, a control algorithm based on the UV-accelerated recovery is developed which facilitates faster leak detection.« less
NASA Astrophysics Data System (ADS)
Raqeema, S.; Hashim, U.; Azizah, N.
2016-07-01
This paper presented the study of surface functionalization on IDE by using 3-Aminopropyl triethoxysilane (APTES). The DNA nanochip based interdigitated (IDE) has been proposed to optimized the sensitivity of the device due to the cervical cancer detection. The DNA nanochip will be more efficient using surface modification of TiO2 nanoparticles with 3-Aminopropyl triethoxysilane (APTES). Furthermore, APTES gain the better functionalization of the adsorption mechanism on IDE. The combination of the DNA probe and the HPV target will produce more sensitivity and speed of the DNA nanochip due to their properties. The IDE has been characterized using current-voltage (IV) measurement. This functionalization of the surface would be applicable, sensitive, selective and low cost for cervical cancer detection.
Plasmonic SERS nanochips and nanoprobes for medical diagnostics and bio-energy applications
NASA Astrophysics Data System (ADS)
Ngo, Hoan T.; Wang, Hsin-Neng; Crawford, Bridget M.; Fales, Andrew M.; Vo-Dinh, Tuan
2017-02-01
The development of rapid, easy-to-use, cost-effective, high accuracy, and high sensitive DNA detection methods for molecular diagnostics has been receiving increasing interest. Over the last five years, our laboratory has developed several chip-based DNA detection techniques including the molecular sentinel-on-chip (MSC), the multiplex MSC, and the inverse molecular sentinel-on-chip (iMS-on-Chip). In these techniques, plasmonic surface-enhanced Raman scattering (SERS) Nanowave chips were functionalized with DNA probes for single-step DNA detection. Sensing mechanisms were based on hybridization of target sequences and DNA probes, resulting in a distance change between SERS reporters and the Nanowave chip's gold surface. This distance change resulted in change in SERS intensity, thus indicating the presence and capture of the target sequences. Our techniques were single-step DNA detection techniques. Target sequences were detected by simple delivery of sample solutions onto DNA probe-functionalized Nanowave chips and SERS signals were measured after 1h - 2h incubation. Target sequence labeling or washing to remove unreacted components was not required, making the techniques simple, easy-to-use, and cost effective. The usefulness of the techniques for medical diagnostics was illustrated by the detection of genetic biomarkers for respiratory viral infection and of dengue virus 4 DNA.
Thousands of chemicals for which limited toxicological data are available are used and then detected in humans and the environment. Rapid and cost-effective approaches for assessing the toxicological properties of chemicals are needed. We used CRISPR-Cas9 functional genomic scree...
NASA Astrophysics Data System (ADS)
Li, Xuxu; Li, Xinyang; wang, Caixia
2018-03-01
This paper proposes an efficient approach to decrease the computational costs of correlation-based centroiding methods used for point source Shack-Hartmann wavefront sensors. Four typical similarity functions have been compared, i.e. the absolute difference function (ADF), ADF square (ADF2), square difference function (SDF), and cross-correlation function (CCF) using the Gaussian spot model. By combining them with fast search algorithms, such as three-step search (TSS), two-dimensional logarithmic search (TDL), cross search (CS), and orthogonal search (OS), computational costs can be reduced drastically without affecting the accuracy of centroid detection. Specifically, OS reduces calculation consumption by 90%. A comprehensive simulation indicates that CCF exhibits a better performance than other functions under various light-level conditions. Besides, the effectiveness of fast search algorithms has been verified.
Qian, Zhi-Ming; Wang, Shuo Hong; Cheng, Xi En; Chen, Yan Qiu
2016-06-23
Fish tracking is an important step for video based analysis of fish behavior. Due to severe body deformation and mutual occlusion of multiple swimming fish, accurate and robust fish tracking from video image sequence is a highly challenging problem. The current tracking methods based on motion information are not accurate and robust enough to track the waving body and handle occlusion. In order to better overcome these problems, we propose a multiple fish tracking method based on fish head detection. The shape and gray scale characteristics of the fish image are employed to locate the fish head position. For each detected fish head, we utilize the gray distribution of the head region to estimate the fish head direction. Both the position and direction information from fish detection are then combined to build a cost function of fish swimming. Based on the cost function, global optimization method can be applied to associate the target between consecutive frames. Results show that our method can accurately detect the position and direction information of fish head, and has a good tracking performance for dozens of fish. The proposed method can successfully obtain the motion trajectories for dozens of fish so as to provide more precise data to accommodate systematic analysis of fish behavior.
U-Shaped and Surface Functionalized Polymer Optical Fiber Probe for Glucose Detection.
Azkune, Mikel; Ruiz-Rubio, Leire; Aldabaldetreku, Gotzon; Arrospide, Eneko; Pérez-Álvarez, Leyre; Bikandi, Iñaki; Zubia, Joseba; Vilas-Vilela, Jose Luis
2017-12-25
In this work we show an optical fiber evanescent wave absorption probe for glucose detection in different physiological media. High selectivity is achieved by functionalizing the surface of an only-core poly(methyl methacrylate) (PMMA) polymer optical fiber with phenilboronic groups, and enhanced sensitivity by using a U-shaped geometry. Employing a supercontinuum light source and a high-resolution spectrometer, absorption measurements are performed in the broadband visible light spectrum. Experimental results suggest the feasibility of such a fiber probe as a low-cost and selective glucose detector.
CMOS capacitive biosensors for highly sensitive biosensing applications.
Chang, An-Yu; Lu, Michael S-C
2013-01-01
Magnetic microbeads are widely used in biotechnology and biomedical research for manipulation and detection of cells and biomolecules. Most lab-on-chip systems capable of performing manipulation and detection require external instruments to perform one of the functions, leading to increased size and cost. This work aims at developing an integrated platform to perform these two functions by implementing electromagnetic microcoils and capacitive biosensors on a CMOS (complementary metal oxide semiconductor) chip. Compared to most magnetic-type sensors, our detection method requires no externally applied magnetic fields and the associated fabrication is less complicated. In our experiment, microbeads coated with streptavidin were driven to the sensors located in the center of microcoils with functionalized anti-streptavidin antibody. Detection of a single microbead was successfully demonstrated using a capacitance-to-frequency readout. The average capacitance changes for the experimental and control groups were -5.3 fF and -0.2 fF, respectively.
Neelemaat, Floor; Bosmans, Judith E; Thijs, Abel; Seidell, Jaap C; van Bokhorst-de van der Schueren, Marian A E
2012-04-01
Older people are vulnerable to malnutrition which leads to increased health care costs. The aim of this study was to evaluate the cost-effectiveness of nutritional supplementation from a societal perspective. This randomized controlled trial included hospital admitted malnourished elderly (≥ 60 y) patients. Patients in the intervention group received nutritional supplementation (energy and protein enriched diet, oral nutritional support, calcium-vitamin D supplement, telephone counselling by a dietician) until three months after discharge from hospital. Patients in the control group received usual care (control). Primary outcomes were Quality Adjusted Life Years (QALYs), physical activities and functional limitations. Measurements were performed at hospital admission and three months after discharge. Data were analyzed according to the intention-to-treat principle and multiple imputation was used to impute missing data. Incremental cost-effectiveness ratios were calculated and bootstrapping was applied to evaluate cost-effectiveness. Cost-effectiveness was expressed by cost-effectiveness planes and cost-effectiveness acceptability curves. 210 patients were included, 105 in each group. After three months, no statistically significant differences in quality of life and physical activities were observed between groups. Functional limitations decreased significantly more in the intervention group (mean difference -0.72, 95% CI-1.15; -0.28). There were no differences in costs between groups. Cost-effectiveness for QALYs and physical activities could not be demonstrated. For functional limitations we found a 0.95 probability that the intervention is cost-effective in comparison with usual care for ceiling ratios > €6500. A multi-component nutritional intervention to malnourished elderly patients for three months after hospital discharge leads to significant improvement in functional limitations and is neutral in costs. A follow-up of three months is probably too short to detect changes in QALYs or physical activities. Copyright © 2011 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.
NASA Astrophysics Data System (ADS)
Joshi, V.; Manivannan, N.; Jarry, Z.; Carmichael, J.; Vahtel, M.; Zamora, G.; Calder, C.; Simon, J.; Burge, M.; Soliz, P.
2018-02-01
Diabetic peripheral neuropathy (DPN) accounts for around 73,000 lower-limb amputations annually in the US on patients with diabetes. Early detection of DPN is critical. Current clinical methods for diagnosing DPN are subjective and effective only at later stages. Until recently, thermal cameras used for medical imaging have been expensive and hence prohibitive to be installed in primary care setting. The objective of this study is to compare results from a low-cost thermal camera with a high-end thermal camera used in screening for DPN. Thermal imaging has demonstrated changes in microvascular function that correlates with nerve function affected by DPN. The limitations for using low-cost cameras for DPN imaging are: less resolution (active pixels), frame rate, thermal sensitivity etc. We integrated two FLIR Lepton (80x60 active pixels, 50° HFOV, thermal sensitivity < 50mK) as one unit. Right and left cameras record the videos of right and left foot respectively. A compactible embedded system (raspberry pi3 model Bv1.2) is used to configure the sensors, capture and stream the video via ethernet. The resulting video has 160x120 active pixels (8 frames/second). We compared the temperature measurement of feet obtained using low-cost camera against the gold standard highend FLIR SC305. Twelve subjects (aged 35-76) were recruited. Difference in the temperature measurements between cameras was calculated for each subject and the results show that the difference between the temperature measurements of two cameras (mean difference=0.4, p-value=0.2) is not statistically significant. We conclude that the low-cost thermal camera system shows potential for use in detecting early-signs of DPN in under-served and rural clinics.
Peterson, G W; McEntee, M; Harris, C R; Klevitch, A D; Fountain, A W; Soliz, J R; Balboa, A; Hauser, A J
2016-11-01
Electrical impedance spectroscopy, in conjunction with the metal-organic framework (MOF) UiO-66-NH 2 , is used to detect trace levels of the explosive simulant 2,6-dinitrotoluene. The combination of porosity and functionality of the MOF provides an effective dielectric structure, resulting in changes of impedance magnitude and phase angle. The promising data indicate that MOFs may be used in low-cost, robust explosive detection devices.
Stahl, Joachim S; Wang, Song
2008-03-01
Many natural and man-made structures have a boundary that shows a certain level of bilateral symmetry, a property that plays an important role in both human and computer vision. In this paper, we present a new grouping method for detecting closed boundaries with symmetry. We first construct a new type of grouping token in the form of symmetric trapezoids by pairing line segments detected from the image. A closed boundary can then be achieved by connecting some trapezoids with a sequence of gap-filling quadrilaterals. For such a closed boundary, we define a unified grouping cost function in a ratio form: the numerator reflects the boundary information of proximity and symmetry and the denominator reflects the region information of the enclosed area. The introduction of the region-area information in the denominator is able to avoid a bias toward shorter boundaries. We then develop a new graph model to represent the grouping tokens. In this new graph model, the grouping cost function can be encoded by carefully designed edge weights and the desired optimal boundary corresponds to a special cycle with a minimum ratio-form cost. We finally show that such a cycle can be found in polynomial time using a previous graph algorithm. We implement this symmetry-grouping method and test it on a set of synthetic data and real images. The performance is compared to two previous grouping methods that do not consider symmetry in their grouping cost functions.
Li, Zhanming; Fu, Yingchun; Fang, Weihuan; Li, Yanbin
2015-01-01
Escherichia coli O157:H7 is a predominant foodborne pathogen with severe pathogenicity, leading to increasing attention given to rapid and sensitive detection. Herein, we propose an impedance biosensor using new kinds of screen-printed interdigitated microelectrodes (SPIMs) and wheat germ agglutinin (WGA) for signal amplification to detect E. coli O157:H7 with high sensitivity and time-efficiency. The SPIMs integrate the high sensitivity and short response time of the interdigitated electrodes and the low cost of the screen-printed electrodes. Self-assembling of bi-functional 3-dithiobis-(sulfosuccinimidyl-propionate) (DTSP) on the SPIMs was investigated and was proved to be able to improve adsorption quantity and stability of biomaterials. WGA was further adopted to enhance the signal taking advantage of the abundant lectin-binding sites on the bacteria surface. The immunosensor exhibited a detection limit of 102 cfu·mL−1, with a linear detection range from 102 to 107 cfu·mL−1 (r2 = 0.98). The total detection time was less than 1 h, showing its comparable sensitivity and rapid response. Furthermore, the low cost of one SPIM significantly reduced the detection cost of the biosensor. The biosensor may have great promise in food safety analysis and lead to a portable biosensing system for routine monitoring of foodborne pathogens. PMID:26251911
A Cost Estimation Analysis of U.S. Navy Ship Fuel-Savings Techniques and Technologies
2009-09-01
readings to the boiler operator. The PLC will provide constant automatic trimming of the excess oxygen based upon real time SGA readings. An SCD...the author): The Aegis Combat System is controlled by an advanced, automatic detect-and-track, multi-function three-dimensional passive...subsequently offloaded. An Online Wash System would reduce these maintenance costs and improve fuel efficiency of these engines by keeping the engines
Cyber-Physical Trade-Offs in Distributed Detection Networks
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rao, Nageswara S; Yao, David K. Y.; Chin, J. C.
2010-01-01
We consider a network of sensors that measure the scalar intensity due to the background or a source combined with background, inside a two-dimensional monitoring area. The sensor measurements may be random due to the underlying nature of the source and background or due to sensor errors or both. The detection problem is infer the presence of a source of unknown intensity and location based on sensor measurements. In the conventional approach, detection decisions are made at the individual sensors, which are then combined at the fusion center, for example using the majority rule. With increased communication and computation costs,more » we show that a more complex fusion algorithm based on measurements achieves better detection performance under smooth and non-smooth source intensity functions, Lipschitz conditions on probability ratios and a minimum packing number for the state-space. We show that these conditions for trade-offs between the cyber costs and physical detection performance are applicable for two detection problems: (i) point radiation sources amidst background radiation, and (ii) sources and background with Gaussian distributions.« less
NASA Astrophysics Data System (ADS)
Baruah, Upama; Chowdhury, Devasish
2016-04-01
Functionalized graphene oxide quantum dots (GOQDs)-poly(vinyl alcohol) (PVA) hybrid hydrogels were prepared using a simple, facile and cost-effective strategy. GOQDs bearing different surface functional groups were introduced as the cross-linking agent into the PVA matrix thereby resulting in gelation. The four different types of hybrid hydrogels were prepared using graphene oxide, reduced graphene oxide, ester functionalized graphene oxide and amine functionalized GOQDs as cross-linking agents. It was observed that the hybrid hydrogel prepared with amine functionalized GOQDs was the most stable. The potential applicability of using this solid sensing platform has been subsequently explored in an easy, simple, effective and sensitive method for optical detection of M2+ (Fe2+, Co2+ and Cu2+) in aqueous media involving colorimetric detection. Amine functionalized GOQDs-PVA hybrid hydrogel when put into the corresponding solution of Fe2+, Co2+ and Cu2+ renders brown, orange and blue coloration respectively of the solution detecting the presence of Fe2+, Co2+ and Cu2+ ions in the solution. The minimum detection limit observed was 1 × 10-7 M using UV-visible spectroscopy. Further, the applicability of the sensing material was also tested for a mixture of co-existing ions in solution to demonstrate the practical applicability of the system. Insight into the probable mechanistic pathway involved in the detection process is also being discussed.
Wu, Wei; Liu, Li; Dai, Zhigao; Liu, Juhua; Yang, Shuanglei; Zhou, Li; Xiao, Xiangheng; Jiang, Changzhong; Roy, Vellaisamy A.L.
2015-01-01
Ideal SERS substrates for sensing applications should exhibit strong signal enhancement, generate a reproducible and uniform response, and should be able to fabricate in large-scale and low-cost. Herein, we demonstrate low-cost, highly sensitive, disposable and reproducible SERS substrates by means of screen printing Ag nanoparticles (NPs) on a plastic PET (Polyethylene terephthalate) substrates. While there are many complex methods for the fabrication of SERS substrates, screen printing is suitable for large-area fabrication and overcomes the uneven radial distribution. Using as-printed Ag substrates as the SERS platform, detection of various commonly known chemicals have been done. The SERS detection limit of Rhodamine 6G (R6G) is higher than the concentration of 1 × 10−10 M. The relative standard deviation (RSD) value for 784 points on the detection of R6G and Malachite green (MG) is less than 20% revealing a homogeneous SERS distribution and high reproducibility. Moreover, melamine (MA) is detected in fresh liquid-milk without additional pretreatment, which may accelerate the application of rapid on-line detection of MA in liquid milk. Our screen printing method highlights the use of large-scale printing strategies for the fabrication of well-defined functional nanostructures with applications well beyond the field of SERS sensing. PMID:25974125
Hyperspherical Sparse Approximation Techniques for High-Dimensional Discontinuity Detection
Zhang, Guannan; Webster, Clayton G.; Gunzburger, Max; ...
2016-08-04
This work proposes a hyperspherical sparse approximation framework for detecting jump discontinuities in functions in high-dimensional spaces. The need for a novel approach results from the theoretical and computational inefficiencies of well-known approaches, such as adaptive sparse grids, for discontinuity detection. Our approach constructs the hyperspherical coordinate representation of the discontinuity surface of a function. Then sparse approximations of the transformed function are built in the hyperspherical coordinate system, with values at each point estimated by solving a one-dimensional discontinuity detection problem. Due to the smoothness of the hypersurface, the new technique can identify jump discontinuities with significantly reduced computationalmore » cost, compared to existing methods. Several approaches are used to approximate the transformed discontinuity surface in the hyperspherical system, including adaptive sparse grid and radial basis function interpolation, discrete least squares projection, and compressed sensing approximation. Moreover, hierarchical acceleration techniques are also incorporated to further reduce the overall complexity. In conclusion, rigorous complexity analyses of the new methods are provided, as are several numerical examples that illustrate the effectiveness of our approach.« less
A Hyperspherical Adaptive Sparse-Grid Method for High-Dimensional Discontinuity Detection
Zhang, Guannan; Webster, Clayton G.; Gunzburger, Max D.; ...
2015-06-24
This study proposes and analyzes a hyperspherical adaptive hierarchical sparse-grid method for detecting jump discontinuities of functions in high-dimensional spaces. The method is motivated by the theoretical and computational inefficiencies of well-known adaptive sparse-grid methods for discontinuity detection. Our novel approach constructs a function representation of the discontinuity hypersurface of an N-dimensional discontinuous quantity of interest, by virtue of a hyperspherical transformation. Then, a sparse-grid approximation of the transformed function is built in the hyperspherical coordinate system, whose value at each point is estimated by solving a one-dimensional discontinuity detection problem. Due to the smoothness of the hypersurface, the newmore » technique can identify jump discontinuities with significantly reduced computational cost, compared to existing methods. In addition, hierarchical acceleration techniques are also incorporated to further reduce the overall complexity. Rigorous complexity analyses of the new method are provided as are several numerical examples that illustrate the effectiveness of the approach.« less
A hyper-spherical adaptive sparse-grid method for high-dimensional discontinuity detection
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Guannan; Webster, Clayton G.; Gunzburger, Max D.
This work proposes and analyzes a hyper-spherical adaptive hierarchical sparse-grid method for detecting jump discontinuities of functions in high-dimensional spaces is proposed. The method is motivated by the theoretical and computational inefficiencies of well-known adaptive sparse-grid methods for discontinuity detection. Our novel approach constructs a function representation of the discontinuity hyper-surface of an N-dimensional dis- continuous quantity of interest, by virtue of a hyper-spherical transformation. Then, a sparse-grid approximation of the transformed function is built in the hyper-spherical coordinate system, whose value at each point is estimated by solving a one-dimensional discontinuity detection problem. Due to the smoothness of themore » hyper-surface, the new technique can identify jump discontinuities with significantly reduced computational cost, compared to existing methods. Moreover, hierarchical acceleration techniques are also incorporated to further reduce the overall complexity. Rigorous error estimates and complexity analyses of the new method are provided as are several numerical examples that illustrate the effectiveness of the approach.« less
Interrogation of electrical connector faults using miniaturized UWB sources
NASA Astrophysics Data System (ADS)
Tokgöz, Çaǧata; Dardona, Sameh
2017-01-01
A diagnostic method for the detection, identification, and characterization of precursors of faults due to partial insertion of pin-socket contacts within electrical connectors commonly used in avionics systems is presented. It is demonstrated that a miniaturized ultrawideband (UWB) source and a minispectrum analyzer can be employed to measure resonant frequency shifts in connector S parameters as a small and low-cost alternative to a large and expensive network analyzer. The transfer function of an electrical connector is represented as a ratio of the spectra measured using the spectrum analyzer with and without the connector. Alternatively, the transfer function is derived in terms of the connector S parameters and the reflection coefficients at both ports of the connector. The transfer function data obtained using this derivation agreed well with its representation as a measured spectral ratio. The derivation enabled the extraction of the connector S parameters from the measured transfer function data as a function of the insertion depth of a pin-socket contact within the connector. In comparison with the S parameters measured directly using a network analyzer at multiple insertion depths, the S parameters extracted from the measured transfer function showed consistent and reliable representation of the electrical connector fault. The results demonstrate the potential of integrating a low-cost miniaturized UWB device into a connector harness for real-time detection of precursors to partially inserted connector faults.
Unobtrusive monitoring of heart rate using a cost-effective speckle-based SI-POF remote sensor
NASA Astrophysics Data System (ADS)
Pinzón, P. J.; Montero, D. S.; Tapetado, A.; Vázquez, C.
2017-03-01
A novel speckle-based sensing technique for cost-effective heart-rate monitoring is demonstrated. This technique detects periodical changes in the spatial distribution of energy on the speckle pattern at the output of a Step-Index Polymer Optical Fiber (SI-POF) lead by using a low-cost webcam. The scheme operates in reflective configuration thus performing a centralized interrogation unit scheme. The prototype has been integrated into a mattress and its functionality has been tested with 5 different patients lying on the mattress in different positions without direct contact with the fiber sensing lead.
Learning a cost function for microscope image segmentation.
Nilufar, Sharmin; Perkins, Theodore J
2014-01-01
Quantitative analysis of microscopy images is increasingly important in clinical researchers' efforts to unravel the cellular and molecular determinants of disease, and for pathological analysis of tissue samples. Yet, manual segmentation and measurement of cells or other features in images remains the norm in many fields. We report on a new system that aims for robust and accurate semi-automated analysis of microscope images. A user interactively outlines one or more examples of a target object in a training image. We then learn a cost function for detecting more objects of the same type, either in the same or different images. The cost function is incorporated into an active contour model, which can efficiently determine optimal boundaries by dynamic programming. We validate our approach and compare it to some standard alternatives on three different types of microscopic images: light microscopy of blood cells, light microscopy of muscle tissue sections, and electron microscopy cross-sections of axons and their myelin sheaths.
Gold Nanoparticle Based Platforms for Circulating Cancer Marker Detection
Huang, Xiaohua; O'Connor, Ryan; Kwizera, Elyahb Allie
2017-01-01
Detection of cancer-related circulating biomarkers in body fluids has become a cutting-edge technology that has the potential to noninvasively screen cancer, diagnose cancer at early stage, monitor tumor progression, and evaluate therapy responses. Traditional molecular and cellular detection methods are either insensitive for early cancer intervention or technically costly and complicated making them impractical for typical clinical settings. Due to their exceptional structural and functional properties that are not available from bulk materials or discrete molecules, nanotechnology is opening new horizons for low cost, rapid, highly sensitive, and highly specific detection of circulating cancer markers. Gold nanoparticles have emerged as a unique nanoplatform for circulating biomarker detection owning to their advantages of easy synthesis, facile surface chemistry, excellent biocompatibility, and remarkable structure and environment sensitive optical properties. In this review, we introduce current gold nanoparticle-based technology platforms for the detection of four major classes of circulating cancer markers - circulating tumor cells, vesicles, nucleic acids, and proteins. The techniques will be summarized in terms of signal detection strategies. Distinctive examples are provided to highlight the state-of-the-art technologies that significantly advance basic and clinical cancer research. PMID:28217434
GNSS Spoofing Detection and Mitigation Based on Maximum Likelihood Estimation
Li, Hong; Lu, Mingquan
2017-01-01
Spoofing attacks are threatening the global navigation satellite system (GNSS). The maximum likelihood estimation (MLE)-based positioning technique is a direct positioning method originally developed for multipath rejection and weak signal processing. We find this method also has a potential ability for GNSS anti-spoofing since a spoofing attack that misleads the positioning and timing result will cause distortion to the MLE cost function. Based on the method, an estimation-cancellation approach is presented to detect spoofing attacks and recover the navigation solution. A statistic is derived for spoofing detection with the principle of the generalized likelihood ratio test (GLRT). Then, the MLE cost function is decomposed to further validate whether the navigation solution obtained by MLE-based positioning is formed by consistent signals. Both formulae and simulations are provided to evaluate the anti-spoofing performance. Experiments with recordings in real GNSS spoofing scenarios are also performed to validate the practicability of the approach. Results show that the method works even when the code phase differences between the spoofing and authentic signals are much less than one code chip, which can improve the availability of GNSS service greatly under spoofing attacks. PMID:28665318
GNSS Spoofing Detection and Mitigation Based on Maximum Likelihood Estimation.
Wang, Fei; Li, Hong; Lu, Mingquan
2017-06-30
Spoofing attacks are threatening the global navigation satellite system (GNSS). The maximum likelihood estimation (MLE)-based positioning technique is a direct positioning method originally developed for multipath rejection and weak signal processing. We find this method also has a potential ability for GNSS anti-spoofing since a spoofing attack that misleads the positioning and timing result will cause distortion to the MLE cost function. Based on the method, an estimation-cancellation approach is presented to detect spoofing attacks and recover the navigation solution. A statistic is derived for spoofing detection with the principle of the generalized likelihood ratio test (GLRT). Then, the MLE cost function is decomposed to further validate whether the navigation solution obtained by MLE-based positioning is formed by consistent signals. Both formulae and simulations are provided to evaluate the anti-spoofing performance. Experiments with recordings in real GNSS spoofing scenarios are also performed to validate the practicability of the approach. Results show that the method works even when the code phase differences between the spoofing and authentic signals are much less than one code chip, which can improve the availability of GNSS service greatly under spoofing attacks.
Katchman, Benjamin A.; Smith, Joseph T.; Obahiagbon, Uwadiae; Kesiraju, Sailaja; Lee, Yong-Kyun; O’Brien, Barry; Kaftanoglu, Korhan; Blain Christen, Jennifer; Anderson, Karen S.
2016-01-01
Point-of-care molecular diagnostics can provide efficient and cost-effective medical care, and they have the potential to fundamentally change our approach to global health. However, most existing approaches are not scalable to include multiple biomarkers. As a solution, we have combined commercial flat panel OLED display technology with protein microarray technology to enable high-density fluorescent, programmable, multiplexed biorecognition in a compact and disposable configuration with clinical-level sensitivity. Our approach leverages advances in commercial display technology to reduce pre-functionalized biosensor substrate costs to pennies per cm2. Here, we demonstrate quantitative detection of IgG antibodies to multiple viral antigens in patient serum samples with detection limits for human IgG in the 10 pg/mL range. We also demonstrate multiplexed detection of antibodies to the HPV16 proteins E2, E6, and E7, which are circulating biomarkers for cervical as well as head and neck cancers. PMID:27374875
Katchman, Benjamin A; Smith, Joseph T; Obahiagbon, Uwadiae; Kesiraju, Sailaja; Lee, Yong-Kyun; O'Brien, Barry; Kaftanoglu, Korhan; Blain Christen, Jennifer; Anderson, Karen S
2016-07-04
Point-of-care molecular diagnostics can provide efficient and cost-effective medical care, and they have the potential to fundamentally change our approach to global health. However, most existing approaches are not scalable to include multiple biomarkers. As a solution, we have combined commercial flat panel OLED display technology with protein microarray technology to enable high-density fluorescent, programmable, multiplexed biorecognition in a compact and disposable configuration with clinical-level sensitivity. Our approach leverages advances in commercial display technology to reduce pre-functionalized biosensor substrate costs to pennies per cm(2). Here, we demonstrate quantitative detection of IgG antibodies to multiple viral antigens in patient serum samples with detection limits for human IgG in the 10 pg/mL range. We also demonstrate multiplexed detection of antibodies to the HPV16 proteins E2, E6, and E7, which are circulating biomarkers for cervical as well as head and neck cancers.
A Simple low-cost device enables four epi-illumination techniques on standard light microscopes.
Ishmukhametov, Robert R; Russell, Aidan N; Wheeler, Richard J; Nord, Ashley L; Berry, Richard M
2016-02-08
Back-scattering darkfield (BSDF), epi-fluorescence (EF), interference reflection contrast (IRC), and darkfield surface reflection (DFSR) are advanced but expensive light microscopy techniques with limited availability. Here we show a simple optical design that combines these four techniques in a simple low-cost miniature epi-illuminator, which inserts into the differential interference-contrast (DIC) slider bay of a commercial microscope, without further additions required. We demonstrate with this device: 1) BSDF-based detection of Malarial parasites inside unstained human erythrocytes; 2) EF imaging with and without dichroic components, including detection of DAPI-stained Leishmania parasite without using excitation or emission filters; 3) RIC of black lipid membranes and other thin films, and 4) DFSR of patterned opaque and transparent surfaces. We believe that our design can expand the functionality of commercial bright field microscopes, provide easy field detection of parasites and be of interest to many users of light microscopy.
A Simple low-cost device enables four epi-illumination techniques on standard light microscopes
NASA Astrophysics Data System (ADS)
Ishmukhametov, Robert R.; Russell, Aidan N.; Wheeler, Richard J.; Nord, Ashley L.; Berry, Richard M.
2016-02-01
Back-scattering darkfield (BSDF), epi-fluorescence (EF), interference reflection contrast (IRC), and darkfield surface reflection (DFSR) are advanced but expensive light microscopy techniques with limited availability. Here we show a simple optical design that combines these four techniques in a simple low-cost miniature epi-illuminator, which inserts into the differential interference-contrast (DIC) slider bay of a commercial microscope, without further additions required. We demonstrate with this device: 1) BSDF-based detection of Malarial parasites inside unstained human erythrocytes; 2) EF imaging with and without dichroic components, including detection of DAPI-stained Leishmania parasite without using excitation or emission filters; 3) RIC of black lipid membranes and other thin films, and 4) DFSR of patterned opaque and transparent surfaces. We believe that our design can expand the functionality of commercial bright field microscopes, provide easy field detection of parasites and be of interest to many users of light microscopy.
Louie, Raphael J; Tonneson, Jennifer E; Gowarty, Minda; Goodney, Philip P; Barth, Richard J; Rosenkranz, Kari M
2015-11-01
Current National Comprehensive Cancer Network guidelines for breast cancer staging include pre-treatment complete blood count (CBC) and liver function tests (LFT) to screen for occult metastatic disease. To date, the relevance of these tests in detecting metastatic disease in asymptomatic women with early-stage breast cancer (Stage I/II) has not been demonstrated. Although chest x-rays are no longer recommended in the NCCN guidelines, many centers continue to include this imaging as part of their screening process. We aim to determine the clinical and financial impact of these labs and x-rays in the evaluation of early-stage breast cancer patients. A single institution IRB-approved retrospective chart review was conducted of patients with biopsy-proven invasive breast cancer treated from January 1, 2005–December 31, 2009. We collected patient demographics, clinical and pathologic staging, chest x-ray, CBC, and LFT results at the time of referral. Patients were stratified according to radiographic stage at the time of diagnosis. We obtained Medicare reimbursement fees for cost analysis. From 2005 to 2009, 1609 patients with biopsy-proven invasive breast cancer were treated at our institution. Of the 1082 patients with radiographic stage I/II disease, 27.3 % of patients had abnormal CBCs. No additional testing was performed to evaluate these abnormalities. In the early-stage population, 24.7 % of patients had elevated LFTs, resulting in 84 additional imaging studies. No metastatic disease was detected. The cost of CBC, LFTs and chest x-rays was $110.20 per patient, totaling $106,410.99. Additional tests prompted by abnormal results cost $58,143.30 over the five-year period. We found that pre-treatment CBCs, LFTs, and chest x-rays did not improve detection of occult metastatic disease but resulted in additional financial costs. Avoiding routine ordering of these tests would save the US healthcare system $25.7 million annually.
NASA Astrophysics Data System (ADS)
Hao, Qiushi; Zhang, Xin; Wang, Yan; Shen, Yi; Makis, Viliam
2018-07-01
Acoustic emission (AE) technology is sensitive to subliminal rail defects, however strong wheel-rail contact rolling noise under high-speed condition has gravely impeded detecting of rail defects using traditional denoising methods. In this context, the paper develops an adaptive detection method for rail cracks, which combines multiresolution analysis with an improved adaptive line enhancer (ALE). To obtain elaborate multiresolution information of transient crack signals with low computational cost, lifting scheme-based undecimated wavelet packet transform is adopted. In order to feature the impulsive property of crack signals, a Shannon entropy-improved ALE is proposed as a signal enhancing approach, where Shannon entropy is introduced to improve the cost function. Then a rail defect detection plan based on the proposed method for high-speed condition is put forward. From theoretical analysis and experimental verification, it is demonstrated that the proposed method has superior performance in enhancing the rail defect AE signal and reducing the strong background noise, offering an effective multiresolution approach for rail defect detection under high-speed and strong-noise condition.
Restless Tuneup of High-Fidelity Qubit Gates
NASA Astrophysics Data System (ADS)
Rol, M. A.; Bultink, C. C.; O'Brien, T. E.; de Jong, S. R.; Theis, L. S.; Fu, X.; Luthi, F.; Vermeulen, R. F. L.; de Sterke, J. C.; Bruno, A.; Deurloo, D.; Schouten, R. N.; Wilhelm, F. K.; DiCarlo, L.
2017-04-01
We present a tuneup protocol for qubit gates with tenfold speedup over traditional methods reliant on qubit initialization by energy relaxation. This speedup is achieved by constructing a cost function for Nelder-Mead optimization from real-time correlation of nondemolition measurements interleaving gate operations without pause. Applying the protocol on a transmon qubit achieves 0.999 average Clifford fidelity in one minute, as independently verified using randomized benchmarking and gate-set tomography. The adjustable sensitivity of the cost function allows the detection of fractional changes in the gate error with a nearly constant signal-to-noise ratio. The restless concept demonstrated can be readily extended to the tuneup of two-qubit gates and measurement operations.
High-Throughput Functional Validation of Progression Drivers in Lung Adenocarcinoma
2013-09-01
2) a novel molecular barcoding approach that facilitates cost- effective detection of driver events following in vitro and in vivo functional screens...aberration construction pipeline, which we named High-Throughput 3 Mutagenesis and Molecular Barcoding (HiTMMoB; Fig.1). We have therefore been able...lentiviral vector specially constructed for this project. This vector is compatible with our flexible molecular barcoding technology (Fig. 1), thus each
Moghimi-Dehkordi, Bijan; Vahedi, Mohsen; Pourhoseingholi, Mohammad Amin; Khoshkrood Mansoori, Babak; Safaee, Azadeh; Habibi, Manijeh; Pourhoseingholi, Asma; Zali, Mohammad Reza
2011-10-01
While few population-based studies on the economic burden of functional bowel disorders (FBD) have been published from developing countries like Iran, this study aimed to estimate their direct and indirect costs for five groups of patients: irritable bowel syndrome (IBS), functional constipation (FC), unspecified-FBD (U-FBD), functional abdominal bloating (FAB) and functional diarrhea (FD). Up to 18,180 adults randomly sampled from Tehran, Iran (2006-2007) were interviewed using two questionnaires based on the Rome III criteria to detect FBD patients and to estimate their medical expenses (such as visiting the doctor, drugs, hospitalization and laboratory tests) and productivity loss in the previous 6 months. All costs were converted to dollar purchasing power parity (PPP$) to facilitate cross-country comparisons. The mean total 6-month costs were approximately: 160, 147, 103, 96 and 42 PPP$ for IBS, FC, U-FBD, FAB and FD, respectively. The highest proportion of drug consumption was found in IBS patients. The highest mean duration of absence from work was seen in IBS patients (2.26 days). Overall, doctor visit costs accounted for approximately 1/3 of the total costs for FBD, followed by hospitalization. A higher indirect cost of illness was found in IBS (54 PPP$), whereas it was zero in FD. The economic burden of FBD seems to be moderately high in Iran and it imposes a relatively heavy financial burden on the Iranian national health system because of its high prevalence and its impact on quality of life, productivity and waste of resources. © 2011 The Authors. Journal of Digestive Diseases © 2011 Chinese Medical Association Shanghai Branch, Chinese Society of Gastroenterology, Renji Hospital Affiliated to Shanghai Jiaotong University School of Medicine and Blackwell Publishing Asia Pty Ltd.
Automatic segmentation of pulmonary fissures in x-ray CT images using anatomic guidance
NASA Astrophysics Data System (ADS)
Ukil, Soumik; Sonka, Milan; Reinhardt, Joseph M.
2006-03-01
The pulmonary lobes are the five distinct anatomic divisions of the human lungs. The physical boundaries between the lobes are called the lobar fissures. Detection of lobar fissure positions in pulmonary X-ray CT images is of increasing interest for the early detection of pathologies, and also for the regional functional analysis of the lungs. We have developed a two-step automatic method for the accurate segmentation of the three pulmonary fissures. In the first step, an approximation of the actual fissure locations is made using a 3-D watershed transform on the distance map of the segmented vasculature. Information from the anatomically labeled human airway tree is used to guide the watershed segmentation. These approximate fissure boundaries are then used to define the region of interest (ROI) for a more exact 3-D graph search to locate the fissures. Within the ROI the fissures are enhanced by computing a ridgeness measure, and this is used as the cost function for the graph search. The fissures are detected as the optimal surface within the graph defined by the cost function, which is computed by transforming the problem to the problem of finding a minimum s-t cut on a derived graph. The accuracy of the lobar borders is assessed by comparing the automatic results to manually traced lobe segments. The mean distance error between manually traced and computer detected left oblique, right oblique and right horizontal fissures is 2.3 +/- 0.8 mm, 2.3 +/- 0.7 mm and 1.0 +/- 0.1 mm, respectively.
Wavelength band selection method for multispectral target detection.
Karlholm, Jörgen; Renhorn, Ingmar
2002-11-10
A framework is proposed for the selection of wavelength bands for multispectral sensors by use of hyperspectral reference data. Using the results from the detection theory we derive a cost function that is minimized by a set of spectral bands optimal in terms of detection performance for discrimination between a class of small rare targets and clutter with known spectral distribution. The method may be used, e.g., in the design of multispectral infrared search and track and electro-optical missile warning sensors, where a low false-alarm rate and a high-detection probability for detection of small targets against a clutter background are of critical importance, but the required high frame rate prevents the use of hyperspectral sensors.
NASA Astrophysics Data System (ADS)
Ferhati, H.; Djeffal, F.
2017-12-01
In this paper, a new junctionless optical controlled field effect transistor (JL-OCFET) and its comprehensive theoretical model is proposed to achieve high optical performance and low cost fabrication process. Exhaustive study of the device characteristics and comparison between the proposed junctionless design and the conventional inversion mode structure (IM-OCFET) for similar dimensions are performed. Our investigation reveals that the proposed design exhibits an outstanding capability to be an alternative to the IM-OCFET due to the high performance and the weak signal detection benefit offered by this design. Moreover, the developed analytical expressions are exploited to formulate the objective functions to optimize the device performance using Genetic Algorithms (GAs) approach. The optimized JL-OCFET not only demonstrates good performance in terms of derived drain current and responsivity, but also exhibits superior signal to noise ratio, low power consumption, high-sensitivity, high ION/IOFF ratio and high-detectivity as compared to the conventional IM-OCFET counterpart. These characteristics make the optimized JL-OCFET potentially suitable for developing low cost and ultrasensitive photodetectors for high-performance and low cost inter-chips data communication applications.
Lockhart, Thurmon E; Soangra, Rahul; Zhang, Jian; Wu, Xuefan
2013-01-01
Mobility characteristics associated with activity of daily living such as sitting down, lying down, rising up, and walking are considered to be important in maintaining functional independence and healthy life style especially for the growing elderly population. Characteristics of postural transitions such as sit-to-stand are widely used by clinicians as a physical indicator of health, and walking is used as an important mobility assessment tool. Many tools have been developed to assist in the assessment of functional levels and to detect a persons activities during daily life. These include questionnaires, observation, diaries, kinetic and kinematic systems, and validated functional tests. These measures are costly and time consuming, rely on subjective patient recall and may not accurately reflect functional ability in the patients home. In order to provide a low-cost, objective assessment of functional ability, inertial measurement unit (IMU) using MEMS technology has been employed to ascertain ADLs. These measures facilitate long-term monitoring of activity of daily living using wearable sensors. IMU system are desirable in monitoring human postures since they respond to both frequency and the intensity of movements and measure both dc (gravitational acceleration vector) and ac (acceleration due to body movement) components at a low cost. This has enabled the development of a small, lightweight, portable system that can be worn by a free-living subject without motion impediment TEMPO (Technology Enabled Medical Precision Observation). Using this IMU system, we acquired indirect measures of biomechanical variables that can be used as an assessment of individual mobility characteristics with accuracy and recognition rates that are comparable to the modern motion capture systems. In this study, five subjects performed various ADLs and mobility measures such as posture transitions and gait characteristics were obtained. We developed postural event detection and classification algorithm using denoised signals from single wireless IMU placed at sternum. The algorithm was further validated and verified with motion capture system in laboratory environment. Wavelet denoising highlighted postural events and transition durations that further provided clinical information on postural control and motor coordination. The presented method can be applied in real life ambulatory monitoring approaches for assessing condition of elderly.
Wavelet based automated postural event detection and activity classification with single IMU (TEMPO)
Lockhart, Thurmon E.; Soangra, Rahul; Zhang, Jian; Wu, Xuefang
2013-01-01
Mobility characteristics associated with activity of daily living such as sitting down, lying down, rising up, and walking are considered to be important in maintaining functional independence and healthy life style especially for the growing elderly population. Characteristics of postural transitions such as sit-to-stand are widely used by clinicians as a physical indicator of health, and walking is used as an important mobility assessment tool. Many tools have been developed to assist in the assessment of functional levels and to detect a person’s activities during daily life. These include questionnaires, observation, diaries, kinetic and kinematic systems, and validated functional tests. These measures are costly and time consuming, rely on subjective patient recall and may not accurately reflect functional ability in the patient’s home. In order to provide a low-cost, objective assessment of functional ability, inertial measurement unit (IMU) using MEMS technology has been employed to ascertain ADLs. These measures facilitate long-term monitoring of activity of daily living using wearable sensors. IMU system are desirable in monitoring human postures since they respond to both frequency and the intensity of movements and measure both dc (gravitational acceleration vector) and ac (acceleration due to body movement) components at a low cost. This has enabled the development of a small, lightweight, portable system that can be worn by a free-living subject without motion impediment - TEMPO. Using the TEMPO system, we acquired indirect measures of biomechanical variables that can be used as an assessment of individual mobility characteristics with accuracy and recognition rates that are comparable to the modern motion capture systems. In this study, five subjects performed various ADLs and mobility measures such as posture transitions and gait characteristics were obtained. We developed postural event detection and classification algorithm using denoised signals from single wireless inertial measurement unit (TEMPO) placed at sternum. The algorithm was further validated and verified with motion capture system in laboratory environment. Wavelet denoising highlighted postural events and transition durations that further provided clinical information on postural control and motor coordination. The presented method can be applied in real life ambulatory monitoring approaches for assessing condition of elderly. PMID:23686204
Biosensors and bioelectronics on smartphone for portable biochemical detection.
Zhang, Diming; Liu, Qingjun
2016-01-15
Smartphone has been widely integrated with sensors, such as test strips, sensor chips, and hand-held detectors, for biochemical detections due to its portability and ubiquitous availability. Utilizing built-in function modules, smartphone is often employed as controller, analyzer, and displayer for rapid, real-time, and point-of-care monitoring, which can significantly simplify design and reduce cost of the detecting systems. This paper presents a review of biosensors and bioelectronics on smartphone for portable biochemical detections. The biosensors and bioelectronics based on smartphone can mainly be classified into biosensors using optics, surface plasmon resonance, electrochemistry, and near-field communication. The developments of these biosensors and bioelectronics on smartphone are reviewed along with typical biochemical detecting cases. Sensor strategies, detector attachments, and coupling methods are highlighted to show designs of the compact, lightweight, and low-cost sensor systems. The performances and advantages of these designs are introduced with their applications in healthcare diagnosis, environment monitoring, and food evaluation. With advances in micro-manufacture, sensor technology, and miniaturized electronics, biosensor and bioelectronic devices on smartphone can be used to perform biochemical detections as common and convenient as electronic tag readout in foreseeable future. Copyright © 2015 Elsevier B.V. All rights reserved.
Smaller to larger biomolecule detection using a lab-built surface plasmon resonance based instrument
NASA Astrophysics Data System (ADS)
Lukose, J.; Kulal, V.; Chidangil, S.; Sinha, R. K.
2016-10-01
We have developed a low-cost surface plasmon resonance (SPR) instrument based on the Kretschmann configuration for biosensing applications. The fabricated instrument is capable of operating in both angular and intensity interrogation schemes. The proposed sensor has proved enormously versatile by detecting a range of analytes with low to high molecular weights. The refractive index based sensor has been used for detecting the variation in the concentration of the aqueous solution of glucose and glycerine. Real time immobilization of protein molecules, bovine serum albumin on a gold (Au) film surface, has also been detected using the SPR imaging technique. Alkanethiol functionalization of the Au surface was performed, and bovine serum albumin was immobilized onto the carboxyl functionalized surface using amine reactive cross linker chemistry. In future, the present approach can also be utilized for the selective detection of a wide range of target biomolecules with the help of specific capture probes, as well as for monitoring protein-drug interactions.
Cost of ownership for inspection equipment
NASA Astrophysics Data System (ADS)
Dance, Daren L.; Bryson, Phil
1993-08-01
Cost of Ownership (CoO) models are increasingly a part of the semiconductor equipment evaluation and selection process. These models enable semiconductor manufacturers and equipment suppliers to quantify a system in terms of dollars per wafer. Because of the complex nature of the semiconductor manufacturing process, there are several key attributes that must be considered in order to accurately reflect the true 'cost of ownership'. While most CoO work to date has been applied to production equipment, the need to understand cost of ownership for inspection and metrology equipment presents unique challenges. Critical parameters such as detection sensitivity as a function of size and type of defect are not included in current CoO models yet are, without question, major factors in the technical evaluation process and life-cycle cost. This paper illustrates the relationship between these parameters, as components of the alpha and beta risk, and cost of ownership.
Maximal Neighbor Similarity Reveals Real Communities in Networks
Žalik, Krista Rizman
2015-01-01
An important problem in the analysis of network data is the detection of groups of densely interconnected nodes also called modules or communities. Community structure reveals functions and organizations of networks. Currently used algorithms for community detection in large-scale real-world networks are computationally expensive or require a priori information such as the number or sizes of communities or are not able to give the same resulting partition in multiple runs. In this paper we investigate a simple and fast algorithm that uses the network structure alone and requires neither optimization of pre-defined objective function nor information about number of communities. We propose a bottom up community detection algorithm in which starting from communities consisting of adjacent pairs of nodes and their maximal similar neighbors we find real communities. We show that the overall advantage of the proposed algorithm compared to the other community detection algorithms is its simple nature, low computational cost and its very high accuracy in detection communities of different sizes also in networks with blurred modularity structure consisting of poorly separated communities. All communities identified by the proposed method for facebook network and E-Coli transcriptional regulatory network have strong structural and functional coherence. PMID:26680448
Rasooly, Reuven; Bruck, Hugh Alan; Balsam, Joshua; Prickril, Ben; Ossandon, Miguel; Rasooly, Avraham
2016-05-17
Resource-poor countries and regions require effective, low-cost diagnostic devices for accurate identification and diagnosis of health conditions. Optical detection technologies used for many types of biological and clinical analysis can play a significant role in addressing this need, but must be sufficiently affordable and portable for use in global health settings. Most current clinical optical imaging technologies are accurate and sensitive, but also expensive and difficult to adapt for use in these settings. These challenges can be mitigated by taking advantage of affordable consumer electronics mobile devices such as webcams, mobile phones, charge-coupled device (CCD) cameras, lasers, and LEDs. Low-cost, portable multi-wavelength fluorescence plate readers have been developed for many applications including detection of microbial toxins such as C. Botulinum A neurotoxin, Shiga toxin, and S. aureus enterotoxin B (SEB), and flow cytometry has been used to detect very low cell concentrations. However, the relatively low sensitivities of these devices limit their clinical utility. We have developed several approaches to improve their sensitivity presented here for webcam based fluorescence detectors, including (1) image stacking to improve signal-to-noise ratios; (2) lasers to enable fluorescence excitation for flow cytometry; and (3) streak imaging to capture the trajectory of a single cell, enabling imaging sensors with high noise levels to detect rare cell events. These approaches can also help to overcome some of the limitations of other low-cost optical detection technologies such as CCD or phone-based detectors (like high noise levels or low sensitivities), and provide for their use in low-cost medical diagnostics in resource-poor settings.
Rasooly, Reuven; Bruck, Hugh Alan; Balsam, Joshua; Prickril, Ben; Ossandon, Miguel; Rasooly, Avraham
2016-01-01
Resource-poor countries and regions require effective, low-cost diagnostic devices for accurate identification and diagnosis of health conditions. Optical detection technologies used for many types of biological and clinical analysis can play a significant role in addressing this need, but must be sufficiently affordable and portable for use in global health settings. Most current clinical optical imaging technologies are accurate and sensitive, but also expensive and difficult to adapt for use in these settings. These challenges can be mitigated by taking advantage of affordable consumer electronics mobile devices such as webcams, mobile phones, charge-coupled device (CCD) cameras, lasers, and LEDs. Low-cost, portable multi-wavelength fluorescence plate readers have been developed for many applications including detection of microbial toxins such as C. Botulinum A neurotoxin, Shiga toxin, and S. aureus enterotoxin B (SEB), and flow cytometry has been used to detect very low cell concentrations. However, the relatively low sensitivities of these devices limit their clinical utility. We have developed several approaches to improve their sensitivity presented here for webcam based fluorescence detectors, including (1) image stacking to improve signal-to-noise ratios; (2) lasers to enable fluorescence excitation for flow cytometry; and (3) streak imaging to capture the trajectory of a single cell, enabling imaging sensors with high noise levels to detect rare cell events. These approaches can also help to overcome some of the limitations of other low-cost optical detection technologies such as CCD or phone-based detectors (like high noise levels or low sensitivities), and provide for their use in low-cost medical diagnostics in resource-poor settings. PMID:27196933
Edge grouping combining boundary and region information.
Stahl, Joachim S; Wang, Song
2007-10-01
This paper introduces a new edge-grouping method to detect perceptually salient structures in noisy images. Specifically, we define a new grouping cost function in a ratio form, where the numerator measures the boundary proximity of the resulting structure and the denominator measures the area of the resulting structure. This area term introduces a preference towards detecting larger-size structures and, therefore, makes the resulting edge grouping more robust to image noise. To find the optimal edge grouping with the minimum grouping cost, we develop a special graph model with two different kinds of edges and then reduce the grouping problem to finding a special kind of cycle in this graph with a minimum cost in ratio form. This optimal cycle-finding problem can be solved in polynomial time by a previously developed graph algorithm. We implement this edge-grouping method, test it on both synthetic data and real images, and compare its performance against several available edge-grouping and edge-linking methods. Furthermore, we discuss several extensions of the proposed method, including the incorporation of the well-known grouping cues of continuity and intensity homogeneity, introducing a factor to balance the contributions from the boundary and region information, and the prevention of detecting self-intersecting boundaries.
Integrated optical biosensor for rapid detection of bacteria
NASA Astrophysics Data System (ADS)
Mathesz, Anna; Valkai, Sándor; Újvárosy, Attila; Aekbote, Badri; Sipos, Orsolya; Stercz, Balázs; Kocsis, Béla; Szabó, Dóra; Dér, András
2016-02-01
In medical diagnostics, rapid detection of pathogenic bacteria from body fluids is one of the basic issues. Most state-of-the-art methods require optical labeling, increasing the complexity, duration and cost of the analysis. Therefore, there is a strong need for developing selective sensory devices based on label-free techniques, in order to increase the speed, and reduce the cost of detection. In a recent paper, we have shown that an integrated optical Mach-Zehnder interferometer, a highly sensitive all-optical device made of a cheap photopolymer, can be used as a powerful lab-on-a-chip tool for specific, labelfree detection of proteins. By proper modifications of this technique, our interferometric biosensor was combined with a microfluidic system allowing the rapid and specific detection of bacteria from solutions, having the surface of the sensor functionalized by bacterium-specific antibodies. The experiments proved that the biosensor was able to detect Escherichia coli bacteria at concentrations of 106 cfu/ml within a few minutes, that makes our device an appropriate tool for fast, label-free detection of bacteria from body fluids such as urine or sputum. On the other hand, possible applications of the device may not be restricted to medical microbiology, since bacterial identification is an important task in microbial forensics, criminal investigations, bio-terrorism threats and in environmental studies, as well.
Integrated optical biosensor for rapid detection of bacteria
NASA Astrophysics Data System (ADS)
Mathesz, Anna; Valkai, Sándor; Újvárosy, Attila; Aekbote, Badri; Sipos, Orsolya; Stercz, Balázs; Kocsis, Béla; Szabó, Dóra; Dér, András
2015-12-01
In medical diagnostics, rapid detection of pathogenic bacteria from body fluids is one of the basic issues. Most state-of-the-art methods require optical labeling, increasing the complexity, duration and cost of the analysis. Therefore, there is a strong need for developing selective sensory devices based on label-free techniques, in order to increase the speed, and reduce the cost of detection. In a recent paper, we have shown that an integrated optical Mach-Zehnder interferometer, a highly sensitive all-optical device made of a cheap photopolymer, can be used as a powerful lab-on-a-chip tool for specific, labelfree detection of proteins. By proper modifications of this technique, our interferometric biosensor was combined with a microfluidic system allowing the rapid and specific detection of bacteria from solutions, having the surface of the sensor functionalized by bacterium-specific antibodies. The experiments proved that the biosensor was able to detect Escherichia coli bacteria at concentrations of 106 cfu/ml within a few minutes, that makes our device an appropriate tool for fast, label-free detection of bacteria from body fluids such as urine or sputum. On the other hand, possible applications of the device may not be restricted to medical microbiology, since bacterial identification is an important task in microbial forensics, criminal investigations, bio-terrorism threats and in environmental studies, as well.
Schmid, Karen Barros; Scherer, Luciene; Barcellos, Regina Bones; Kuhleis, Daniele; Prestes, Isaías Valente; Steffen, Ricardo Ewbank; Dalla Costa, Elis Regina; Rossetti, Maria Lucia Rosa
2014-12-16
Prison conditions can favor the spread of tuberculosis (TB). This study aimed to evaluate in a Brazilian prison: the performance and accuracy of smear, culture and Detect-TB; performance of smear plus culture and smear plus Detect-TB, according to different TB prevalence rates; and the cost-effectiveness of these procedures for pulmonary tuberculosis (PTB) diagnosis. This paper describes a cost-effectiveness study. A decision analytic model was developed to estimate the costs and cost-effectiveness of five routine diagnostic procedures for diagnosis of PTB using sputum specimens: a) Smear alone, b) Culture alone, c) Detect-TB alone, d) Smear plus culture and e) Smear plus Detect-TB. The cost-effectiveness ratio of costs were evaluated per correctly diagnosed TB case and all procedures costs were attributed based on the procedure costs adopted by the Brazilian Public Health System. A total of 294 spontaneous sputum specimens from patients suspected of having TB were analyzed. The sensibility and specificity were calculated to be 47% and 100% for smear; 93% and 100%, for culture; 74% and 95%, for Detect-TB; 96% and 100%, for smear plus culture; and 86% and 95%, for smear plus Detect-TB. The negative and positive predictive values for smear plus Detect-TB, according to different TB prevalence rates, ranged from 83 to 99% and 48 to 96%, respectively. In a cost-effectiveness analysis, smear was both less costly and less effective than the other strategies. Culture and smear plus culture were more effective but more costly than the other strategies. Smear plus Detect-TB was the most cost-effective method. The Detect-TB evinced to be sensitive and effective for the PTB diagnosis when applied with smear microscopy. Diagnostic methods should be improved to increase TB case detection. To support rational decisions about the implementation of such techniques, cost-effectiveness studies are essential, including in prisons, which are known for health care assessment problems.
Yamaura, Yuichi; Royle, J. Andrew; Kuboi, Kouji; Tada, Tsuneo; Ikeno, Susumu; Makino, Shun'ichi
2011-01-01
1. In large-scale field surveys, a binary recording of each species' detection or nondetection has been increasingly adopted for its simplicity and low cost. Because of the importance of abundance in many studies, it is desirable to obtain inferences about abundance at species-, functional group-, and community-levels from such binary data. 2. We developed a novel hierarchical multi-species abundance model based on species-level detection/nondetection data. The model accounts for the existence of undetected species, and variability in abundance and detectability among species. Species-level detection/nondetection is linked to species- level abundance via a detection model that accommodates the expectation that probability of detection (at least one individuals is detected) increases with local abundance of the species. We applied this model to a 9-year dataset composed of the detection/nondetection of forest birds, at a single post-fire site (from 7 to 15 years after fire) in a montane area of central Japan. The model allocated undetected species into one of the predefined functional groups by assuming a prior distribution on individual group membership. 3. The results suggest that 15–20 species were missed in each year, and that species richness of communities and functional groups did not change with post-fire forest succession. Overall abundance of birds and abundance of functional groups tended to increase over time, although only in the winter, while decreases in detectabilities were observed in several species. 4. Synthesis and applications. Understanding and prediction of large-scale biodiversity dynamics partly hinge on how we can use data effectively. Our hierarchical model for detection/nondetection data estimates abundance in space/time at species-, functional group-, and community-levels while accounting for undetected individuals and species. It also permits comparison of multiple communities by many types of abundance-based diversity and similarity measures under imperfect detection.
NASA Astrophysics Data System (ADS)
Gambhir, Monika; Gupta, Shilpi; John, Priya; Mahakud, Ramakanta; Kumar, Jitendra; Prakash, Om
2018-03-01
We present development of a compact and label-free sensor based on the surface modification of copper vapor laser fabricated long period fiber gratings for detection of airborne Aspergillus niger (A. niger) fungal spores. Surface of sensors were functionalized with monoclonal glucose oxidases IgG1 for target-specific covalent binding. In process of functionalization and binding of 103 cfu/ml of pathogenic A. niger fungal spores, notable shorter wave transition in resonance wavelength from 1562.93 nm to 1555.97 nm, and significant reduction in peak loss from 61.72 dB to 57.48 dB were recorded. The implementation was cost effective and yielded instantaneous results.
Restless Tuneup of High-Fidelity Qubit Gates
NASA Astrophysics Data System (ADS)
Rol, M. A.; Bultink, C. C.; O'Brien, T. E.; de Jong, S. R.; Theis, L. S.; Fu, X.; Luthi, F.; Vermeulen, R. F. L.; de Sterke, J. C.; Bruno, A.; Deurloo, D.; Schouten, R. N.; Wilhelm, F. K.; Dicarlo, L.
We present a tuneup protocol for qubit gates with tenfold speedup over traditional methods reliant on qubit initialization by energy relax- ation. This speedup is achieved by constructing a cost function for Nelder-Mead optimization from real-time correlation of non-demolition measurements interleaving gate operations without pause. Applying the protocol on a transmon qubit achieves 0.999 average Clifford fidelity in one minute, as independently verified using randomized benchmarking and gate set tomography. The adjustable sensitivity of the cost function allows detecting fractional reductions in gate error with constant signal- to-noise ratio. The restless concept here demonstrated can be readily extended to the tuneup of two-qubit gates and measurement operations. Research funded by IARPA, an ERC Synergy Grant, Microsoft Research, and the China Scholarship Council.
Text-line extraction in handwritten Chinese documents based on an energy minimization framework.
Koo, Hyung Il; Cho, Nam Ik
2012-03-01
Text-line extraction in unconstrained handwritten documents remains a challenging problem due to nonuniform character scale, spatially varying text orientation, and the interference between text lines. In order to address these problems, we propose a new cost function that considers the interactions between text lines and the curvilinearity of each text line. Precisely, we achieve this goal by introducing normalized measures for them, which are based on an estimated line spacing. We also present an optimization method that exploits the properties of our cost function. Experimental results on a database consisting of 853 handwritten Chinese document images have shown that our method achieves a detection rate of 99.52% and an error rate of 0.32%, which outperforms conventional methods.
Morrison, Sarah A; Lorenz, Douglas; Eskay, Carol P; Forrest, Gail F; Basso, D Michele
2018-03-01
To determine the impact of long-term, body weight-supported locomotor training after chronic, incomplete spinal cord injury (SCI), and to estimate the health care costs related to lost recovery potential and preventable secondary complications that may have occurred because of visit limits imposed by insurers. Prospective observational cohort with longitudinal follow-up. Eight outpatient rehabilitation centers that participate in the Christopher & Dana Reeve Foundation NeuroRecovery Network (NRN). Individuals with motor incomplete chronic SCI (American Spinal Injury Association Impairment Scale C or D; N=69; 0.1-45y after SCI) who completed at least 120 NRN physical therapy sessions. Manually assisted locomotor training (LT) in a body weight-supported treadmill environment, overground standing and stepping activities, and community integration tasks. International Standards for Neurological Classification of Spinal Cord Injury motor and sensory scores, orthostatic hypotension, bowel/bladder/sexual function, Spinal Cord Injury Functional Ambulation Inventory (SCI-FAI), Berg Balance Scale, Modified Functional Reach, 10-m walk test, and 6-minute walk test. Longitudinal outcome measure collection occurred every 20 treatments and at 6- to 12-month follow-up after discharge from therapy. Significant improvement occurred for upper and lower motor strength, functional activities, psychological arousal, sensation of bowel movement, and SCI-FAI community ambulation. Extended training enabled minimal detectable changes at 60, 80, 100, and 120 sessions. After detectable change occurred, it was sustained through 120 sessions and continued 6 to 12 months after treatment. Delivering at least 120 sessions of LT improves recovery from incomplete chronic SCI. Because walking reduces rehospitalization, LT delivered beyond the average 20-session insurance limit can reduce rehospitalizations and long-term health costs. Copyright © 2018 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Andrei, Veronica; Sharpe, Erica; Vasilescu, Alina; Andreescu, Silvana
2016-08-15
We report the development and characterization of a disposable single use electrochemical sensor based on the oxidase-like activity of nanoceria particles for the detection of phenolic antioxidants. The use of nanoceria in the sensor design enables oxidation of phenolic compounds, particularly those with ortho-dihydroxybenzene functionality, to their corresponding quinones at the surface of a screen printed carbon electrode. Detection is carried out by electrochemical reduction of the resulting quinone at a low applied potential of -0.1V vs the Ag/AgCl electrode. The sensor was optimized and characterized with respect to particle loading, applied potential, response time, detection limit, linear concentration range and sensitivity. The method enabled rapid detection of common phenolic antioxidants including caffeic acid, gallic acid and quercetin in the µM concentration range, and demonstrated good functionality for the analysis of antioxidant content in several wine samples. The intrinsic oxidase-like activity of nanoceria shows promise as a robust tool for sensitive and cost effective analysis of antioxidants using electrochemical detection. Copyright © 2016 Elsevier B.V. All rights reserved.
Tapered Polymer Fiber Sensors for Reinforced Concrete Beam Vibration Detection.
Luo, Dong; Ibrahim, Zainah; Ma, Jianxun; Ismail, Zubaidah; Iseley, David Thomas
2016-12-16
In this study, tapered polymer fiber sensors (TPFSs) have been employed to detect the vibration of a reinforced concrete beam (RC beam). The sensing principle was based on transmission modes theory. The natural frequency of an RC beam was theoretically analyzed. Experiments were carried out with sensors mounted on the surface or embedded in the RC beam. Vibration detection results agreed well with Kistler accelerometers. The experimental results found that both the accelerometer and TPFS detected the natural frequency function of a vibrated RC beam well. The mode shapes of the RC beam were also found by using the TPFSs. The proposed vibration detection method provides a cost-comparable solution for a structural health monitoring (SHM) system in civil engineering.
Tapered Polymer Fiber Sensors for Reinforced Concrete Beam Vibration Detection
Luo, Dong; Ibrahim, Zainah; Ma, Jianxun; Ismail, Zubaidah; Iseley, David Thomas
2016-01-01
In this study, tapered polymer fiber sensors (TPFSs) have been employed to detect the vibration of a reinforced concrete beam (RC beam). The sensing principle was based on transmission modes theory. The natural frequency of an RC beam was theoretically analyzed. Experiments were carried out with sensors mounted on the surface or embedded in the RC beam. Vibration detection results agreed well with Kistler accelerometers. The experimental results found that both the accelerometer and TPFS detected the natural frequency function of a vibrated RC beam well. The mode shapes of the RC beam were also found by using the TPFSs. The proposed vibration detection method provides a cost-comparable solution for a structural health monitoring (SHM) system in civil engineering. PMID:27999245
Cost-Effectiveness Analysis of Three Leprosy Case Detection Methods in Northern Nigeria
Ezenduka, Charles; Post, Erik; John, Steven; Suraj, Abdulkarim; Namadi, Abdulahi; Onwujekwe, Obinna
2012-01-01
Background Despite several leprosy control measures in Nigeria, child proportion and disability grade 2 cases remain high while new cases have not significantly reduced, suggesting continuous spread of the disease. Hence, there is the need to review detection methods to enhance identification of early cases for effective control and prevention of permanent disability. This study evaluated the cost-effectiveness of three leprosy case detection methods in Northern Nigeria to identify the most cost-effective approach for detection of leprosy. Methods A cross-sectional study was carried out to evaluate the additional benefits of using several case detection methods in addition to routine practice in two north-eastern states of Nigeria. Primary and secondary data were collected from routine practice records and the Nigerian Tuberculosis and Leprosy Control Programme of 2009. The methods evaluated were Rapid Village Survey (RVS), Household Contact Examination (HCE) and Traditional Healers incentive method (TH). Effectiveness was measured as number of new leprosy cases detected and cost-effectiveness was expressed as cost per case detected. Costs were measured from both providers' and patients' perspectives. Additional costs and effects of each method were estimated by comparing each method against routine practise and expressed as incremental cost-effectiveness ratio (ICER). All costs were converted to the U.S. dollar at the 2010 exchange rate. Univariate sensitivity analysis was used to evaluate uncertainties around the ICER. Results The ICER for HCE was $142 per additional case detected at all contact levels and it was the most cost-effective method. At ICER of $194 per additional case detected, THs method detected more cases at a lower cost than the RVS, which was not cost-effective at $313 per additional case detected. Sensitivity analysis showed that varying the proportion of shared costs and subsistent wage for valuing unpaid time did not significantly change the results. Conclusion Complementing routine practice with household contact examination is the most cost-effective approach to identify new leprosy cases and we recommend that, depending on acceptability and feasibility, this intervention is introduced for improved case detection in Northern Nigeria. PMID:23029580
Detection and Spatial Mapping of Mercury Contamination in Water Samples Using a Smart-Phone
2014-01-01
Detection of environmental contamination such as trace-level toxic heavy metal ions mostly relies on bulky and costly analytical instruments. However, a considerable global need exists for portable, rapid, specific, sensitive, and cost-effective detection techniques that can be used in resource-limited and field settings. Here we introduce a smart-phone-based hand-held platform that allows the quantification of mercury(II) ions in water samples with parts per billion (ppb) level of sensitivity. For this task, we created an integrated opto-mechanical attachment to the built-in camera module of a smart-phone to digitally quantify mercury concentration using a plasmonic gold nanoparticle (Au NP) and aptamer based colorimetric transmission assay that is implemented in disposable test tubes. With this smart-phone attachment that weighs <40 g, we quantified mercury(II) ion concentration in water samples by using a two-color ratiometric method employing light-emitting diodes (LEDs) at 523 and 625 nm, where a custom-developed smart application was utilized to process each acquired transmission image on the same phone to achieve a limit of detection of ∼3.5 ppb. Using this smart-phone-based detection platform, we generated a mercury contamination map by measuring water samples at over 50 locations in California (USA), taken from city tap water sources, rivers, lakes, and beaches. With its cost-effective design, field-portability, and wireless data connectivity, this sensitive and specific heavy metal detection platform running on cellphones could be rather useful for distributed sensing, tracking, and sharing of water contamination information as a function of both space and time. PMID:24437470
Sharp, Peter; Dong, Chongmei
2014-01-01
TILLING is widely used in plant functional genomics. Mutagenesis and SNP detection is combined to allow for the isolation of mutations in genes of interest. It can also be used as a plant breeding tool, whereby variation in known or candidate genes of interest to breeding programs is generated. Here we describe a simple low-cost TILLING procedure.
USDA-ARS?s Scientific Manuscript database
Resource-poor countries and regions require effective, low-cost diagnostic devices for accurate identification and diagnosis of health conditions. Optical detection technologies used for many types of biological and clinical analysis can play a significant role in addressing this need, but must be s...
Sampling efficacy for the red imported fire ant Solenopsis invicta (Hymenoptera: Formicidae).
Stringer, Lloyd D; Suckling, David Maxwell; Baird, David; Vander Meer, Robert K; Christian, Sheree J; Lester, Philip J
2011-10-01
Cost-effective detection of invasive ant colonies before establishment in new ranges is imperative for the protection of national borders and reducing their global impact. We examined the sampling efficiency of food-baits and pitfall traps (baited and nonbaited) in detecting isolated red imported fire ant (Solenopsis invicta Buren) nests in multiple environments in Gainesville, FL. Fire ants demonstrated a significantly higher preference for a mixed protein food type (hotdog or ground meat combined with sweet peanut butter) than for the sugar or water baits offered. Foraging distance success was a function of colony size, detection trap used, and surveillance duration. Colony gyne number did not influence detection success. Workers from small nests (0- to 15-cm mound diameter) traveled no >3 m to a food source, whereas large colonies (>30-cm mound diameter) traveled up to 17 m. Baited pitfall traps performed best at detecting incipient ant colonies followed by nonbaited pitfall traps then food baits, whereas food baits performed well when trying to detect large colonies. These results were used to create an interactive model in Microsoft Excel, whereby surveillance managers can alter trap type, density, and duration parameters to estimate the probability of detecting specified or unknown S. invicta colony sizes. This model will support decision makers who need to balance the sampling cost and risk of failure to detect fire ant colonies.
A new approach for low-cost noninvasive detection of asymptomatic heart disease at rest.
DeMarzo, Arthur P; Calvin, James E
2007-01-01
It would be useful to have an inexpensive, noninvasive point-of-care test for early detection of asymptomatic heart disease. This study used impedance cardiography (ICG) in a new way to assess heart function that did not use stroke volume or cardiac output. There is a model of the ICG dZ/dt waveform that may be used as a template to represent normal heart function. The hypothesis was that a dZ/dt waveform which deviates from that template should indicate heart dysfunction and therefore heart disease. The objective was to assess the accuracy of this new ICG approach, using echocardiography as the standard. Thirty-four outpatients undergoing echocardiographic testing were tested by ICG while sitting upright and supine. All patients had no symptoms or history of a structural or functional heart disorder. Echocardiographic testing showed 17 patients with abnormalities and 17 as normal. ICG testing yielded 16 true positives for heart dysfunction with 1 false negative (sensitivity = 94%) and 17 true negatives with no false positives (specificity = 100%). Considering that the cost, technical skill, and time required for this ICG test are comparable to those of an electrocardiograph, this new approach has potential as a point-of-care screening test for asymptomatic heart disease.
NASA Astrophysics Data System (ADS)
Khezri, Somayeh; Bahram, Morteza; Samadi, Naser
2018-01-01
In this paper, we describe a rapid, low-cost and highly sensitive colorimetric method for the detection of isoprenaline, based on 2-amino-5-mercapto-1,3,4-thiadiazol (AMTD) functionalized gold nanoparticles (AMTD-AuNPs) as a sensing element. Hydrogen bonding interaction between isoprenaline and AMTD resulted in the aggregation of AuNPs and a consequent color change of AuNPs from red to blue. The concentration of isoprenaline could be detected with the naked eye or a UV-visible spectrometer. Results showed that the absorbance ratio (A650/A524) was linear with isoprenaline concentrations in the range of 0.2 to 2.6 μM (R = 0.997). The detection limit of this method was 0.08 μM. The proposed method is simple, without using complicated instruments and adding salts for enhancing sensitivity. This probe could be successfully applied to the determination of isoprenaline in human serum samples and urine samples after deproteinization.
Detection of content adaptive LSB matching: a game theory approach
NASA Astrophysics Data System (ADS)
Denemark, Tomáš; Fridrich, Jessica
2014-02-01
This paper is an attempt to analyze the interaction between Alice and Warden in Steganography using the Game Theory. We focus on the modern steganographic embedding paradigm based on minimizing an additive distortion function. The strategies of both players comprise of the probabilistic selection channel. The Warden is granted the knowledge of the payload and the embedding costs, and detects embedding using the likelihood ratio. In particular, the Warden is ignorant about the embedding probabilities chosen by Alice. When adopting a simple multivariate Gaussian model for the cover, the payoff function in the form of the Warden's detection error can be numerically evaluated for a mutually independent embedding operation. We demonstrate on the example of a two-pixel cover that the Nash equilibrium is different from the traditional Alice's strategy that minimizes the KL divergence between cover and stego objects under an omnipotent Warden. Practical implications of this case study include computing the loss per pixel of Warden's ability to detect embedding due to her ignorance about the selection channel.
Single conducting polymer nanowire based conductometric sensors
NASA Astrophysics Data System (ADS)
Bangar, Mangesh Ashok
The detection of toxic chemicals, gases or biological agents at very low concentrations with high sensitivity and selectivity has been subject of immense interest. Sensors employing electrical signal readout as transduction mechanism offer easy, label-free detection of target analyte in real-time. Traditional thin film sensors inherently suffered through loss of sensitivity due to current shunting across the charge depleted/added region upon analyte binding to the sensor surface, due to their large cross sectional area. This limitation was overcome by use of nanostructure such as nanowire/tube as transducer where current shunting during sensing was almost eliminated. Due to their benign chemical/electrochemical fabrication route along with excellent electrical properties and biocompatibility, conducting polymers offer cost-effective alternative over other nanostructures. Biggest obstacle in using these nanostructures is lack of easy, scalable and cost-effective way of assembling these nanostructures on prefabricated micropatterns for device fabrication. In this dissertation, three different approaches have been taken to fabricate individual or array of single conducting polymer (and metal) nanowire based devices and using polymer by itself or after functionalization with appropriate recognition molecule they have been applied for gas and biochemical detection. In the first approach electrochemical fabrication of multisegmented nanowires with middle functional Ppy segment along with ferromagnetic nickel (Ni) and end gold segments for better electrical contact was studied. This multi-layered nanowires were used along with ferromagnetic contact electrode for controlled magnetic assembly of nanowires into devices and were used for ammonia gas sensing. The second approach uses conducting polymer, polypyrrole (Ppy) nanowires using simple electrophoretic alignment and maskless electrodeposition to anchor nanowire which were further functionalized with antibodies against cancer marker protein (Cancer Antigen, CA 125) using covalent immobilization for detection of CA 125 in buffer and human blood plasma. Third approach combined electrochemical deposition of conducting polymer and assembly steps into a single step fabrication & functionalization using e-beam lithographically patterned nano-channels. Using this method array of Ppy nanowires were fabricated. Further during fabrication step, by entrapping recognition molecule (avidin) biofunctionalization was achieved. Subsequently these sensors were used for detection of biotinylated single stranded DNA.
Design of multi-function sensor detection system in coal mine based on ARM
NASA Astrophysics Data System (ADS)
Ge, Yan-Xiang; Zhang, Quan-Zhu; Deng, Yong-Hong
2017-06-01
The traditional coal mine sensor in the specific measurement points, the number and type of channel will be greater than or less than the number of monitoring points, resulting in a waste of resources or cannot meet the application requirements, in order to enable the sensor to adapt to the needs of different occasions and reduce the cost, a kind of multi-functional intelligent sensor multiple sensors and ARM11 the S3C6410 processor is used to design and realize the dust, gas, temperature and humidity sensor functions together, and has storage, display, voice, pictures, data query, alarm and other new functions.
NASA Astrophysics Data System (ADS)
Validi, AbdoulAhad
2014-03-01
This study introduces a non-intrusive approach in the context of low-rank separated representation to construct a surrogate of high-dimensional stochastic functions, e.g., PDEs/ODEs, in order to decrease the computational cost of Markov Chain Monte Carlo simulations in Bayesian inference. The surrogate model is constructed via a regularized alternative least-square regression with Tikhonov regularization using a roughening matrix computing the gradient of the solution, in conjunction with a perturbation-based error indicator to detect optimal model complexities. The model approximates a vector of a continuous solution at discrete values of a physical variable. The required number of random realizations to achieve a successful approximation linearly depends on the function dimensionality. The computational cost of the model construction is quadratic in the number of random inputs, which potentially tackles the curse of dimensionality in high-dimensional stochastic functions. Furthermore, this vector-valued separated representation-based model, in comparison to the available scalar-valued case, leads to a significant reduction in the cost of approximation by an order of magnitude equal to the vector size. The performance of the method is studied through its application to three numerical examples including a 41-dimensional elliptic PDE and a 21-dimensional cavity flow.
SNM detection with an optimized water Cherenkov neutron detector
NASA Astrophysics Data System (ADS)
Dazeley, S.; Sweany, M.; Bernstein, A.
2012-11-01
Special Nuclear Material (SNM) can either spontaneously fission or be induced to do so: either case results in neutron emission. For this reason, neutron detection performs a crucial role in the functionality of Radiation Portal Monitoring (RPM) devices. Since neutrons are highly penetrating and difficult to shield, they could potentially be detected escaping even a well-shielded cargo container. If the shielding were sophisticated, detecting escaping neutrons would require a highly efficient detector with close to full solid angle coverage. In 2008, we reported the successful detection of neutrons with a 250 liter (l) gadolinium doped water Cherenkov prototype [1]—a technology that could potentially be employed cost effectively with full solid angle coverage. More recently we have built and tested both 1-kl and 3.5-kl versions [2], demonstrating that very large, cost effective, non-flammable and environmentally benign neutron detectors can be operated efficiently without being overwhelmed by background. In this paper, we present a new design for a modular system of water-based neutron detectors that could be deployed as a real RPM. The modules contain a number of optimizations that have not previously been combined within a single system. We present simulations of the new system, based on the performance of our previous detectors. Our simulations indicate that an optimized system such as is presented here could achieve SNM sensitivity competitive with a large 3He-based system. Moreover, the realization of large, cost effective neutron detectors could, for the first time, enable the detection of multiple neutrons per fission from within a large object such as a cargo container. Such a signal would provide a robust indication of the presence of fissioning material, reducing the frequency of false alarms while increasing sensitivity.
SNM Detection with an Optimized Water Cherenkov Neutron Detector
Dazeley, S.; Sweany, M.; Bernstein, A.
2012-07-23
Special Nuclear Material (SNM) can either spontaneously fission or be induced to do so: either case results in neutron emission. For this reason, neutron detection performs a crucial role in the functionality of Radiation Portal Monitoring (RPM) devices. Since neutrons are highly penetrating and difficult to shield, they could potentially be detected escaping even a well-shielded cargo container. If the shielding were sophisticated, detecting escaping neutrons would require a highly efficient detector with close to full solid angle coverage. In 2008, we reported the successful detection of neutrons with a 250 liter (l) gadolinium doped water Cherenkov prototype—a technology thatmore » could potentially be employed cost effectively with full solid angle coverage. More recently we have built and tested both 1-kl and 3.5-kl versions, demonstrating that very large, cost effective, non-flammable and environmentally benign neutron detectors can be operated efficiently without being overwhelmed by background. In our paper, we present a new design for a modular system of water-based neutron detectors that could be deployed as a real RPM. The modules contain a number of optimizations that have not previously been combined within a single system. We present simulations of the new system, based on the performance of our previous detectors. These simulations indicate that an optimized system such as is presented here could achieve SNM sensitivity competitive with a large 3He-based system. Moreover, the realization of large, cost effective neutron detectors could, for the first time, enable the detection of multiple neutrons per fission from within a large object such as a cargo container. Such a signal would provide a robust indication of the presence of fissioning material, reducing the frequency of false alarms while increasing sensitivity.« less
Pereiro, Iago; Bendali, Amel; Tabnaoui, Sanae; Alexandre, Lucile; Srbova, Jana; Bilkova, Zuzana; Deegan, Shane; Joshi, Lokesh; Viovy, Jean-Louis; Malaquin, Laurent; Dupuy, Bruno; Descroix, Stéphanie
2017-02-01
A microfluidic method to specifically capture and detect infectious bacteria based on immunorecognition and proliferative power is presented. It involves a microscale fluidized bed in which magnetic and drag forces are balanced to retain antibody-functionalized superparamagnetic beads in a chamber during sample perfusion. Captured cells are then cultivated in situ by infusing nutritionally-rich medium. The system was validated by the direct one-step detection of Salmonella Typhimurium in undiluted unskimmed milk, without pre-treatment. The growth of bacteria induces an expansion of the fluidized bed, mainly due to the volume occupied by the newly formed bacteria. This expansion can be observed with the naked eye, providing simple low-cost detection of only a few bacteria and in a few hours. The time to expansion can also be measured with a low-cost camera, allowing quantitative detection down to 4 cfu (colony forming unit), with a dynamic range of 100 to 10 7 cfu ml -1 in 2 to 8 hours, depending on the initial concentration. This mode of operation is an equivalent of quantitative PCR, with which it shares a high dynamic range and outstanding sensitivity and specificity, operating at the live cell rather than DNA level. Specificity was demonstrated by controls performed in the presence of a 500× excess of non-pathogenic Lactococcus lactis . The system's versatility was demonstrated by its successful application to the detection and quantitation of Escherichia coli O157:H15 and Enterobacter cloacae . This new technology allows fast, low-cost, portable and automated bacteria detection for various applications in food, environment, security and clinics.
Life expectancy and the value of early detection.
Howard, David H
2005-09-01
This paper presents a model of the benefits and costs of early detection of asymptomatic disease as they vary by age. The benefits of early detection tend toward zero as the risk of death from competing causes increases. Costs per detected case also decline with age, assuming that disease incidence rises with age, but are always strictly positive. On balance, there is always an age limit beyond which the costs associated with early detection outweigh the benefits. Application of the model to prostate cancer screening suggests that early detection above age 70 or so is not cost-effective.
Highly-sensitive and large-dynamic diffuse optical tomography system for breast tumor detection
NASA Astrophysics Data System (ADS)
Du, Wenwen; Zhang, Limin; Yin, Guoyan; Zhang, Yanqi; Zhao, Huijuan; Gao, Feng
2018-02-01
Diffuse optical tomography (DOT) as a new functional imaging has important clinical applications in many aspects such as benign and malignant breast tumor detection, tumor staging and so on. For quantitative detection of breast tumor, a three-wavelength continuous-wave DOT prototype system combined the ultra-high sensitivity of the photon-counting detection and the measurement parallelism of the lock-in technique was developed to provide high temporal resolution, high sensitivity, large dynamic detection range and signal-to-noise ratio. Additionally, a CT-analogous scanning mode was proposed to cost-effectively increase the detection data. To evaluate the feasibility of the system, a series of assessments were conducted. The results demonstrate that the system can obtain high linearity, stability and negligible inter-wavelength crosstalk. The preliminary phantom experiments show the absorption coefficient is able to be successfully reconstructed, indicating that the system is one of the ideal platforms for optical breast tumor detection.
Scanning, standoff TDLAS leak imaging and quantification
NASA Astrophysics Data System (ADS)
Wainner, Richard T.; Aubut, Nicholas F.; Laderer, Matthew C.; Frish, Michael B.
2017-05-01
This paper reports a novel quantitative gas plume imaging tool, based on active near-infrared Backscatter Tunable Diode Laser Absorption Spectroscopy (b-TDLAS) technology, designed for upstream natural gas leak applications. The new tool integrates low-cost laser sensors with video cameras to create a highly sensitive gas plume imager that also quantifies emission rate, all in a lightweight handheld ergonomic package. It is intended to serve as a lower-cost, higherperformance, enhanced functionality replacement for traditional passive non-quantitative mid-infrared Optical Gas Imagers (OGI) which are utilized by industry to comply with natural gas infrastructure Leak Detection and Repair (LDAR) requirements. It addresses the need for reliable, robust, low-cost sensors to detect and image methane leaks, and to quantify leak emission rates, focusing on inspections of upstream oil and gas operations, such as well pads, compressors, and gas plants. It provides: 1) Colorized quantified images of path-integrated methane concentration. The images depict methane plumes (otherwise invisible to the eye) actively interrogated by the laser beam overlaid on a visible camera image of the background. The detection sensitivity exceeds passive OGI, thus simplifying the manual task of leak detection and location; and 2) Data and algorithms for using the quantitative information gathered by the active detection technique to deduce plume flux (i.e. methane emission rate). This key capability will enable operators to prioritize leak repairs and thereby minimize the value of lost product, as well as to quantify and minimize greenhouse gas emissions, using a tool that meets EPA LDAR imaging equipment requirements.
Kemeny, Steven Frank; Clyne, Alisa Morss
2011-04-01
Fiber alignment plays a critical role in the structure and function of cells and tissues. While fiber alignment quantification is important to experimental analysis and several different methods for quantifying fiber alignment exist, many studies focus on qualitative rather than quantitative analysis perhaps due to the complexity of current fiber alignment methods. Speed and sensitivity were compared in edge detection and fast Fourier transform (FFT) for measuring actin fiber alignment in cells exposed to shear stress. While edge detection using matrix multiplication was consistently more sensitive than FFT, image processing time was significantly longer. However, when MATLAB functions were used to implement edge detection, MATLAB's efficient element-by-element calculations and fast filtering techniques reduced computation cost 100 times compared to the matrix multiplication edge detection method. The new computation time was comparable to the FFT method, and MATLAB edge detection produced well-distributed fiber angle distributions that statistically distinguished aligned and unaligned fibers in half as many sample images. When the FFT sensitivity was improved by dividing images into smaller subsections, processing time grew larger than the time required for MATLAB edge detection. Implementation of edge detection in MATLAB is simpler, faster, and more sensitive than FFT for fiber alignment quantification.
NASA Astrophysics Data System (ADS)
Lynch, John A.; Zaim, Souhil; Zhao, Jenny; Stork, Alexander; Peterfy, Charles G.; Genant, Harry K.
2000-06-01
A technique for segmentation of articular cartilage from 3D MRI scans of the knee has been developed. It overcomes the limitations of the conventionally used region growing techniques, which are prone to inter- and intra-observer variability, and which can require much manual intervention. We describe a hybrid segmentation method combining expert knowledge with directionally oriented Canny filters, cost functions and cubic splines. After manual initialization, the technique utilized 3 cost functions which aided automated detection of cartilage and its boundaries. Using the sign of the edge strength, and the local direction of the boundary, this technique is more reliable than conventional 'snakes,' and the user had little control over smoothness of boundaries. This means that the automatically detected boundary can conform to the true shape of the real boundary, also allowing reliable detection of subtle local lesions on the normally smooth cartilage surface. Manual corrections, with possible re-optimization were sometimes needed. When compared to the conventionally used region growing techniques, this newly described technique measured local cartilage volume with 3 times better reproducibility, and involved two thirds less human interaction. Combined with the use of 3D image registration, the new technique should also permit unbiased segmentation of followup scans by automated initialization from a baseline segmentation of an earlier scan of the same patient.
Humidity compensation of bad-smell sensing system using a detector tube and a built-in camera
NASA Astrophysics Data System (ADS)
Hirano, Hiroyuki; Nakamoto, Takamichi
2011-09-01
We developed a low-cost sensing system robust against humidity change for detecting and estimating concentration of bad smell, such as hydrogen sulfide and ammonia. In the previous study, we developed automated measurement system for a gas detector tube using a built-in camera instead of the conventional manual inspection of the gas detector tube. Concentration detectable by the developed system ranges from a few tens of ppb to a few tens of ppm. However, we previously found that the estimated concentration depends not only on actual concentration, but on humidity. Here, we established the method to correct the influence of humidity by creating regression function with its inputs of discoloration rate and humidity. We studied 2 methods (Backpropagation, Radial basis function network) to get regression function and evaluated them. Consequently, the system successfully estimated the concentration on a practical level even when humidity changes.
Open Loop Structure Low Cost Integrated Differential Inductive Micro Magnetic Volumetric Bio-Sensors
NASA Astrophysics Data System (ADS)
Khodadadi, Mohammad; Chang, Long; Litvinov, Dimitri
This investigation proposes a study, model, simulate and experiment innovative very low cost Magnetic induction biosensor for point of care diagnostics. The biosensor consists of 2 ``semi-loops'' in a micro fluidic channel, one as a sensor and one as a reference, the design takes advantage of microfabrication processes to produce more precise structures to improve sensitivity. Besides the attractively low cost, this biosensor has many advantages. Since the detector is basically a shaped wire, it is inherently robust and reliable. Typical errors in fabricating the wires will not affect its performance and it is sensing volumetric, unlike GMR-based sensors used in biosensor systems that boast single particle detection. Due to small dimensions the sensors do not need to be calibrated. This sensor also has a large range of detection since its sensitivity is proportional to the excitation frequency. Being able to sense Magnetic nano particles in the volume is an advantage in term of trapping MNPs and sensitivity and functionality. Basically, this new brilliant design, fill the gap between the fabricated sensors and hand wounded sensors.
Knee point search using cascading top-k sorting with minimized time complexity.
Wang, Zheng; Tseng, Shian-Shyong
2013-01-01
Anomaly detection systems and many other applications are frequently confronted with the problem of finding the largest knee point in the sorted curve for a set of unsorted points. This paper proposes an efficient knee point search algorithm with minimized time complexity using the cascading top-k sorting when a priori probability distribution of the knee point is known. First, a top-k sort algorithm is proposed based on a quicksort variation. We divide the knee point search problem into multiple steps. And in each step an optimization problem of the selection number k is solved, where the objective function is defined as the expected time cost. Because the expected time cost in one step is dependent on that of the afterwards steps, we simplify the optimization problem by minimizing the maximum expected time cost. The posterior probability of the largest knee point distribution and the other parameters are updated before solving the optimization problem in each step. An example of source detection of DNS DoS flooding attacks is provided to illustrate the applications of the proposed algorithm.
Design of stepwise screening for prediabetes and type 2 diabetes based on costs and cases detected.
de Graaf, Gimon; Postmus, Douwe; Bakker, Stephan J L; Buskens, Erik
2015-09-01
To provide insight into the trade-off between cost per case detected (CPCD) and the detection rate in questionnaire-based stepwise screening for impaired fasting glucose and undiagnosed type 2 diabetes. We considered a stepwise screening in which individuals whose risk score exceeds a predetermined cutoff value are invited for further blood glucose testing. Using individual patient data to determine questionnaire sensitivity and specificity and external sources to determine screening costs and patient response rates, we rolled back a decision tree to estimate the CPCD and the detection rate for all possible cutoffs on the questionnaire. We found a U-shaped relation between CPCD and detection rate, with high costs per case detected at very low and very high detection rates. Changes in patient response rates had a large impact on both the detection rate and the CPCD, whereas screening costs and questionnaire accuracy mainly impacted the CPCD. Our applied method makes it possible to identify a range of efficient cutoffs where higher detection rates can be achieved at an additional cost per detected patient. This enables decision makers to choose an optimal cutoff based on their willingness to pay for additional detected patients. Copyright © 2015 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Huang, Yun-Tzu; Chang, Chia-Yu; Chen, Wei; Su, Chien-Hao; Hsu, Guo-Cheng; Chang, Chia-Ching
HER2 (human epidermal growth factor receptor 2) is one of the significant surface antigens of breast cancer Trace amount of HER2 protein in human serum is highly correlated to the tumor progression in breast cancers especially in the cases of recurrence. Therefore, HER2 detection of human serum is significant for early detection of cancer recurrence. Conventional HER2 detection approaches may not be sensitive enough or contain highly false positive rate or time consuming for accurate detection. Therefore, a rapid, highly sensitive and specific sensing is highly desired. By using HER2 specific binding peptide functionalized palladium thin film electrochemical electrode the HER2 protein concentration can be determined at sub-nanogram level by electrochemical impedance spectroscopy (EIS) within 10 mins. The Pd nano-film is sputtered on the flexible plastics substrate and reduces the cost of this electrode. Due to the low cost of the electrode, it is designed as a disposable biosensing probe which may reduce the concern of human sample contamination. The self-management after breast cancer operation may be feasible in the near future. Keywords: Electrochemical impedance spectroscopy(EIS), breast cancer, biosensor Corresponding author: ccchang01@faculty.nctu.edu.tw; Cheeshin Technology Co. Collaboration.
Takei, Hiraku; Morishita, Soji; Araki, Marito; Edahiro, Yoko; Sunami, Yoshitaka; Hironaka, Yumi; Noda, Naohiro; Sekiguchi, Yuji; Tsuneda, Satoshi; Ohsaka, Akimichi; Komatsu, Norio
2014-01-01
A gain-of-function mutation in the myeloproliferative leukemia virus (MPL) gene, which encodes the thrombopoietin receptor, has been identified in patients with essential thrombocythemia and primary myelofibrosis, subgroups of classic myeloproliferative neoplasms (MPNs). The presence of MPL gene mutations is a critical diagnostic criterion for these diseases. Here, we developed a rapid, simple, and cost-effective method of detecting two major MPL mutations, MPLW515L/K, in a single PCR assay; we termed this method DARMS (dual amplification refractory mutation system)-PCR. DARMS-PCR is designed to produce three different PCR products corresponding to MPLW515L, MPLW515K, and all MPL alleles. The amplicons are later detected and quantified using a capillary sequencer to determine the relative frequencies of the mutant and wild-type alleles. Applying DARMS-PCR to human specimens, we successfully identified MPL mutations in MPN patients, with the exception of patients bearing mutant allele frequencies below the detection limit (5%) of this method. The MPL mutant allele frequencies determined using DARMS-PCR correlated strongly with the values determined using deep sequencing. Thus, we demonstrated the potential of DARMS-PCR to detect MPL mutations and determine the allele frequencies in a timely and cost-effective manner. PMID:25144224
Takei, Hiraku; Morishita, Soji; Araki, Marito; Edahiro, Yoko; Sunami, Yoshitaka; Hironaka, Yumi; Noda, Naohiro; Sekiguchi, Yuji; Tsuneda, Satoshi; Ohsaka, Akimichi; Komatsu, Norio
2014-01-01
A gain-of-function mutation in the myeloproliferative leukemia virus (MPL) gene, which encodes the thrombopoietin receptor, has been identified in patients with essential thrombocythemia and primary myelofibrosis, subgroups of classic myeloproliferative neoplasms (MPNs). The presence of MPL gene mutations is a critical diagnostic criterion for these diseases. Here, we developed a rapid, simple, and cost-effective method of detecting two major MPL mutations, MPLW515L/K, in a single PCR assay; we termed this method DARMS (dual amplification refractory mutation system)-PCR. DARMS-PCR is designed to produce three different PCR products corresponding to MPLW515L, MPLW515K, and all MPL alleles. The amplicons are later detected and quantified using a capillary sequencer to determine the relative frequencies of the mutant and wild-type alleles. Applying DARMS-PCR to human specimens, we successfully identified MPL mutations in MPN patients, with the exception of patients bearing mutant allele frequencies below the detection limit (5%) of this method. The MPL mutant allele frequencies determined using DARMS-PCR correlated strongly with the values determined using deep sequencing. Thus, we demonstrated the potential of DARMS-PCR to detect MPL mutations and determine the allele frequencies in a timely and cost-effective manner.
Dharmalingam, Anitha; Pawar, Shwetal U; Parelkar, Sandesh V; Shetye, Suruchi S; Ghorpade, Mangala K; Tilve, Gundu H
2017-01-01
The differential cortical function obtained by Tc-99m EC is comparable to that of Tc-99m DMSA. However, identification of scars on Tc-99m EC images needs to be studied. The aim of the study is to evaluate role of Tc-99m EC for detection of scarring and differential cortical function by comparing with Tc-99m DMSA. Prospective observational study of recurrent UTI; minimum 6 weeks after acute episode; when urine examination is negative for pus cells. Forty-seven children with normal positioned kidneys underwent Tc-99m EC and DMSA scintigraphy. The DRF and cortical phase images of both studies in the same image matrix size were evaluated by two independent observers for scarring; Tc-99m DMSA was considered as the gold standard. MS Excel 2007 and GraphPad Instat V3.1 and ROC analysis. There was no significant difference in the detection of scarring using two studies with Cohen's kappa coefficient (κ) 0.932. The sensitivity and specificity of Tc-99m EC for detection of scarring was 98.75% and 99.15%, respectively. There was good agreement between the differential cortical function calculated using two studies. The summed Tc-99m EC images with an acceptable high image contrast allow detection of cortical scarring in patients with normal kidney positions. It is an excellent single-modality comprehensive investigational agent for renal parenchymal defects, function, and excretion evaluation with the added advantages of lower cost, convenience, and low radiation exposure to the child.
A Versatile PDMS/Paper Hybrid Microfluidic Platform for Sensitive Infectious Disease Diagnosis
2015-01-01
Bacterial meningitis is a serious health concern worldwide. Given that meningitis can be fatal and many meningitis cases occurred in high-poverty areas, a simple, low-cost, highly sensitive method is in great need for immediate and early diagnosis of meningitis. Herein, we report a versatile and cost-effective polydimethylsiloxane (PDMS)/paper hybrid microfluidic device integrated with loop-mediated isothermal amplification (LAMP) for the rapid, sensitive, and instrument-free detection of the main meningitis-causing bacteria, Neisseria meningitidis (N. meningitidis). The introduction of paper into the microfluidic device for LAMP reactions enables stable test results over a much longer period of time than a paper-free microfluidic system. This hybrid system also offers versatile functions, by providing not only on-site qualitative diagnostic analysis (i.e., a yes or no answer), but also confirmatory testing and quantitative analysis in laboratory settings. The limit of detection of N. meningitidis is about 3 copies per LAMP zone within 45 min, close to single-bacterium detection sensitivity. In addition, we have achieved simple pathogenic microorganism detection without a laborious sample preparation process and without the use of centrifuges. This low-cost hybrid microfluidic system provides a simple and highly sensitive approach for fast instrument-free diagnosis of N. meningitidis in resource-limited settings. This versatile PDMS/paper microfluidic platform has great potential for the point of care (POC) diagnosis of a wide range of infectious diseases, especially for developing nations. PMID:25019330
A PDMS-based cylindrical hybrid lens for enhanced fluorescence detection in microfluidic systems.
Lin, Bor-Shyh; Yang, Yu-Ching; Ho, Chong-Yi; Yang, Han-Yu; Wang, Hsiang-Yu
2014-02-13
Microfluidic systems based on fluorescence detection have been developed and applied for many biological and chemical applications. Because of the tiny amount of sample in the system; the induced fluorescence can be weak. Therefore, most microfluidic systems deploy multiple optical components or sophisticated equipment to enhance the efficiency of fluorescence detection. However, these strategies encounter common issues of complex manufacturing processes and high costs. In this study; a miniature, cylindrical and hybrid lens made of polydimethylsiloxane (PDMS) to improve the fluorescence detection in microfluidic systems is proposed. The hybrid lens integrates a laser focusing lens and a fluorescence collecting lens to achieve dual functions and simplify optical setup. Moreover, PDMS has advantages of low-cost and straightforward fabrication compared with conventional optical components. The performance of the proposed lens is first examined with two fluorescent dyes and the results show that the lens provides satisfactory enhancement for fluorescence detection of Rhodamine 6G and Nile Red. The overall increments in collected fluorescence signal and detection sensitivity are more than 220% of those without lens, and the detection limits of Rhodamine 6G and Nile red are lowered to 0.01 μg/mL and 0.05 μg/mL, respectively. The hybrid lens is further applied to the detection of Nile red-labeled Chlorella vulgaris cells and it increases both signal intensity and detection sensitivity by more than 520%. The proposed hybrid lens also dramatically reduces the variation in detected signal caused by the deviation in incident angle of excitation light.
Comprehensive, Quantitative Risk Assessment of CO{sub 2} Geologic Sequestration
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lepinski, James
2013-09-30
A Quantitative Failure Modes and Effects Analysis (QFMEA) was developed to conduct comprehensive, quantitative risk assessments on CO{sub 2} capture, transportation, and sequestration or use in deep saline aquifers, enhanced oil recovery operations, or enhanced coal bed methane operations. The model identifies and characterizes potential risks; identifies the likely failure modes, causes, effects and methods of detection; lists possible risk prevention and risk mitigation steps; estimates potential damage recovery costs, mitigation costs and costs savings resulting from mitigation; and ranks (prioritizes) risks according to the probability of failure, the severity of failure, the difficulty of early failure detection and themore » potential for fatalities. The QFMEA model generates the necessary information needed for effective project risk management. Diverse project information can be integrated into a concise, common format that allows comprehensive, quantitative analysis, by a cross-functional team of experts, to determine: What can possibly go wrong? How much will damage recovery cost? How can it be prevented or mitigated? What is the cost savings or benefit of prevention or mitigation? Which risks should be given highest priority for resolution? The QFMEA model can be tailored to specific projects and is applicable to new projects as well as mature projects. The model can be revised and updated as new information comes available. It accepts input from multiple sources, such as literature searches, site characterization, field data, computer simulations, analogues, process influence diagrams, probability density functions, financial analysis models, cost factors, and heuristic best practices manuals, and converts the information into a standardized format in an Excel spreadsheet. Process influence diagrams, geologic models, financial models, cost factors and an insurance schedule were developed to support the QFMEA model. Comprehensive, quantitative risk assessments were conducted on three (3) sites using the QFMEA model: (1) SACROC Northern Platform CO{sub 2}-EOR Site in the Permian Basin, Scurry County, TX, (2) Pump Canyon CO{sub 2}-ECBM Site in the San Juan Basin, San Juan County, NM, and (3) Farnsworth Unit CO{sub 2}-EOR Site in the Anadarko Basin, Ochiltree County, TX. The sites were sufficiently different from each other to test the robustness of the QFMEA model.« less
Hou, Fang; Lesmes, Luis Andres; Kim, Woojae; Gu, Hairong; Pitt, Mark A.; Myung, Jay I.; Lu, Zhong-Lin
2016-01-01
The contrast sensitivity function (CSF) has shown promise as a functional vision endpoint for monitoring the changes in functional vision that accompany eye disease or its treatment. However, detecting CSF changes with precision and efficiency at both the individual and group levels is very challenging. By exploiting the Bayesian foundation of the quick CSF method (Lesmes, Lu, Baek, & Albright, 2010), we developed and evaluated metrics for detecting CSF changes at both the individual and group levels. A 10-letter identification task was used to assess the systematic changes in the CSF measured in three luminance conditions in 112 naïve normal observers. The data from the large sample allowed us to estimate the test–retest reliability of the quick CSF procedure and evaluate its performance in detecting CSF changes at both the individual and group levels. The test–retest reliability reached 0.974 with 50 trials. In 50 trials, the quick CSF method can detect a medium 0.30 log unit area under log CSF change with 94.0% accuracy at the individual observer level. At the group level, a power analysis based on the empirical distribution of CSF changes from the large sample showed that a very small area under log CSF change (0.025 log unit) could be detected by the quick CSF method with 112 observers and 50 trials. These results make it plausible to apply the method to monitor the progression of visual diseases or treatment effects on individual patients and greatly reduce the time, sample size, and costs in clinical trials at the group level. PMID:27120074
NASA Astrophysics Data System (ADS)
Close, Dan; Webb, James; Ripp, Steven; Patterson, Stacey; Sayler, Gary
2012-06-01
Traditionally, human toxicant bioavailability screening has been forced to proceed in either a high throughput fashion using prokaryotic or lower eukaryotic targets with minimal applicability to humans, or in a more expensive, lower throughput manner that uses fluorescent or bioluminescent human cells to directly provide human bioavailability data. While these efforts are often sufficient for basic scientific research, they prevent the rapid and remote identification of potentially toxic chemicals required for modern biosecurity applications. To merge the advantages of high throughput, low cost screening regimens with the direct bioavailability assessment of human cell line use, we re-engineered the bioluminescent bacterial luciferase gene cassette to function autonomously (without exogenous stimulation) within human cells. Optimized cassette expression provides for fully endogenous bioluminescent production, allowing continuous, real time monitoring of the bioavailability and toxicology of various compounds in an automated fashion. To access the functionality of this system, two sets of bioluminescent human cells were developed. The first was programed to suspend bioluminescent production upon toxicological challenge to mimic the non-specific detection of a toxicant. The second induced bioluminescence upon detection of a specific compound to demonstrate autonomous remote target identification. These cells were capable of responding to μM concentrations of the toxicant n-decanal, and allowed for continuous monitoring of cellular health throughout the treatment process. Induced bioluminescence was generated through treatment with doxycycline and was detectable upon dosage at a 100 ng/ml concentration. These results demonstrate that leveraging autonomous bioluminescence allows for low-cost, high throughput direct assessment of toxicant bioavailability.
Facile synthesis of carbon dots with superior sensing ability
NASA Astrophysics Data System (ADS)
Jin, Lin; Li, Jingguo; Liu, Liyun; Wang, Zhenling; Zhang, Xingcai
2018-04-01
Carbon dots (CDs) have various applications in biomedical and environmental field, such as bio-imaging, bio-sensing and heavy metal detection. In this study, a novel class of CDs were synthesized using a one-step hydrothermal method. The fabricated CDs displayed stable photoluminescence, good water solubility, and photo stability. Moreover, the functional groups (carboxylic acid moieties and hydroxyls) on the surface of the obtained CDs enable it with superior sensing ability (e.g., very low detectable concentration for Pb2+: 5 nmol/L). With superior detection sensitivity, excellent fluorescent properties and facile fabrication method, the as-obtained CDs can find practical applications as cost-effective and sensitive chemo-sensors in water and food safety field.
UltraSensitive Mycotoxin Detection by STING Sensors
Actis, Paolo; Jejelowo, Olufisayo; Pourmand, Nader
2010-01-01
Signal Transduction by Ion Nano Gating (STING) technology is a label-free biosensor capable of identifying DNA and proteins. Based on a functionalized quartz nanopipette, the STING sensor includes specific recognition elements for analyte discrimination based on size, shape and charge density. A key feature of this technology is that it doesn't require any nanofabrication facility; each nanopipette can be easily, reproducibly, and inexpensively fabricated and tailored at the bench, thus reducing the cost and the turnaround time. Here, we show that STING sensors are capable of the ultrasensitive detection of HT-2 toxin with a detection limit of 100 fg/ml and compare the STING capabilities with respect to conventional sandwich assay techniques. PMID:20829024
Nonenzymetic glucose sensing using carbon functionalized carbon doped ZnO nanorod arrays
NASA Astrophysics Data System (ADS)
Chakraborty, Pinak; Majumder, Tanmoy; Dhar, Saurab; Mondal, Suvra Prakash
2018-04-01
Fabrication of highly sensitive, long stability and low cost glucose sensors are attractive for biomedical applications and food industries. Most of the commercial glucose sensors are based on enzymatic detection which suffers from problems underlying in enzyme activities. Development of high sensitive, enzyme free sensors is a great challenge for next generation glucose sensing applications. In our study Zinc oxide nanorod sensing electrodes have been grown using low cost hydrothermal route and their nonenzymatic glucose sensing properties have been demonstrated with carbon functionalized, carbon doped ZnO nanorods (C-ZnO NRs) in neutral medium (0.1M PBS, pH 7.4) using cyclic voltammetry and amperometry measurements. The C-ZnO NRs electrodes demonstrated glucose sensitivity˜ 13.66 µAmM-1cm-2 in the concentration range 0.7 - 14 mM.
Cost and detection rate of glaucoma screening with imaging devices in a primary care center
Anton, Alfonso; Fallon, Monica; Cots, Francesc; Sebastian, María A; Morilla-Grasa, Antonio; Mojal, Sergi; Castells, Xavier
2017-01-01
Purpose To analyze the cost and detection rate of a screening program for detecting glaucoma with imaging devices. Materials and methods In this cross-sectional study, a glaucoma screening program was applied in a population-based sample randomly selected from a population of 23,527. Screening targeted the population at risk of glaucoma. Examinations included optic disk tomography (Heidelberg retina tomograph [HRT]), nerve fiber analysis, and tonometry. Subjects who met at least 2 of 3 endpoints (HRT outside normal limits, nerve fiber index ≥30, or tonometry ≥21 mmHg) were referred for glaucoma consultation. The currently established (“conventional”) detection method was evaluated by recording data from primary care and ophthalmic consultations in the same population. The direct costs of screening and conventional detection were calculated by adding the unit costs generated during the diagnostic process. The detection rate of new glaucoma cases was assessed. Results The screening program evaluated 414 subjects; 32 cases were referred for glaucoma consultation, 7 had glaucoma, and 10 had probable glaucoma. The current detection method assessed 677 glaucoma suspects in the population, of whom 29 were diagnosed with glaucoma or probable glaucoma. Glaucoma screening and the conventional detection method had detection rates of 4.1% and 3.1%, respectively, and the cost per case detected was 1,410 and 1,435€, respectively. The cost of screening 1 million inhabitants would be 5.1 million euros and would allow the detection of 4,715 new cases. Conclusion The proposed screening method directed at population at risk allows a detection rate of 4.1% and a cost of 1,410 per case detected. PMID:28243057
Aronoff-Spencer, Eliah; Venkatesh, A G; Sun, Alex; Brickner, Howard; Looney, David; Hall, Drew A
2016-12-15
Yeast cell lines were genetically engineered to display Hepatitis C virus (HCV) core antigen linked to gold binding peptide (GBP) as a dual-affinity biobrick chimera. These multifunctional yeast cells adhere to the gold sensor surface while simultaneously acting as a "renewable" capture reagent for anti-HCV core antibody. This streamlined functionalization and detection strategy removes the need for traditional purification and immobilization techniques. With this biobrick construct, both optical and electrochemical immunoassays were developed. The optical immunoassays demonstrated detection of anti-HCV core antibody down to 12.3pM concentrations while the electrochemical assay demonstrated higher binding constants and dynamic range. The electrochemical format and a custom, low-cost smartphone-based potentiostat ($20 USD) yielded comparable results to assays performed on a state-of-the-art electrochemical workstation. We propose this combination of synthetic biology and scalable, point-of-care sensing has potential to provide low-cost, cutting edge diagnostic capability for many pathogens in a variety of settings. Copyright © 2016 Elsevier B.V. All rights reserved.
Failure Mode Identification Through Clustering Analysis
NASA Technical Reports Server (NTRS)
Arunajadai, Srikesh G.; Stone, Robert B.; Tumer, Irem Y.; Clancy, Daniel (Technical Monitor)
2002-01-01
Research has shown that nearly 80% of the costs and problems are created in product development and that cost and quality are essentially designed into products in the conceptual stage. Currently, failure identification procedures (such as FMEA (Failure Modes and Effects Analysis), FMECA (Failure Modes, Effects and Criticality Analysis) and FTA (Fault Tree Analysis)) and design of experiments are being used for quality control and for the detection of potential failure modes during the detail design stage or post-product launch. Though all of these methods have their own advantages, they do not give information as to what are the predominant failures that a designer should focus on while designing a product. This work uses a functional approach to identify failure modes, which hypothesizes that similarities exist between different failure modes based on the functionality of the product/component. In this paper, a statistical clustering procedure is proposed to retrieve information on the set of predominant failures that a function experiences. The various stages of the methodology are illustrated using a hypothetical design example.
NASA Technical Reports Server (NTRS)
1974-01-01
Weight and cost optimized EOS communication links are determined for 2.25, 7.25, 14.5, 21, and 60 GHz systems and for a 10.6 micron homodyne detection laser system. EOS to ground links are examined for 556, 834, and 1112 km EOS orbits, with ground terminals at the Network Test and Tracking Facility and at Goldstone. Optimized 21 GHz and 10.6 micron links are also examined. For the EOS to Tracking and Data Relay Satellite to ground link, signal-to-noise ratios of the uplink and downlink are also optimized for minimum overall cost or spaceborne weight. Finally, the optimized 21 GHz EOS to ground link is determined for various precipitation rates. All system performance parameters and mission dependent constraints are presented, as are the system cost and weight functional dependencies. The features and capabilities of the computer program to perform the foregoing analyses are described.
Compile-time estimation of communication costs in multicomputers
NASA Technical Reports Server (NTRS)
Gupta, Manish; Banerjee, Prithviraj
1991-01-01
An important problem facing numerous research projects on parallelizing compilers for distributed memory machines is that of automatically determining a suitable data partitioning scheme for a program. Any strategy for automatic data partitioning needs a mechanism for estimating the performance of a program under a given partitioning scheme, the most crucial part of which involves determining the communication costs incurred by the program. A methodology is described for estimating the communication costs at compile-time as functions of the numbers of processors over which various arrays are distributed. A strategy is described along with its theoretical basis, for making program transformations that expose opportunities for combining of messages, leading to considerable savings in the communication costs. For certain loops with regular dependences, the compiler can detect the possibility of pipelining, and thus estimate communication costs more accurately than it could otherwise. These results are of great significance to any parallelization system supporting numeric applications on multicomputers. In particular, they lay down a framework for effective synthesis of communication on multicomputers from sequential program references.
Colorimetric-Based Detection of TNT Explosives Using Functionalized Silica Nanoparticles
Idros, Noorhayati; Ho, Man Yi; Pivnenko, Mike; Qasim, Malik M.; Xu, Hua; Gu, Zhongze; Chu, Daping
2015-01-01
This proof-of-concept study proposes a novel sensing mechanism for selective and label-free detection of 2,4,6-trinitrotoluene (TNT). It is realized by surface chemistry functionalization of silica nanoparticles (NPs) with 3-aminopropyl-triethoxysilane (APTES). The primary amine anchored to the surface of the silica nanoparticles (SiO2-NH2) acts as a capturing probe for TNT target binding to form Meisenheimer amine–TNT complexes. A colorimetric change of the self-assembled (SAM) NP samples from the initial green of a SiO2-NH2 nanoparticle film towards red was observed after successful attachment of TNT, which was confirmed as a result of the increased separation between the nanoparticles. The shift in the peak wavelength of the reflected light normal to the film surface (λpeak) and the associated change of the peak width were measured, and a merit function taking into account their combined effect was proposed for the detection of TNT concentrations from 10−12 to 10−4 molar. The selectivity of our sensing approach is confirmed by using TNT-bound nanoparticles incubated in AptamerX, with 2,4-dinitrotoluene (DNT) and toluene used as control and baseline, respectively. Our results show the repeatable systematic color change with the TNT concentration and the possibility to develop a robust, easy-to-use, and low-cost TNT detection method for performing a sensitive, reliable, and semi-quantitative detection in a wide detection range. PMID:26046595
Kepha, Stella; Kihara, Jimmy H.; Njenga, Sammy M.; Pullan, Rachel L.; Brooker, Simon J.
2014-01-01
Objectives This study evaluates the diagnostic accuracy and cost-effectiveness of the Kato-Katz and Mini-FLOTAC methods for detection of soil-transmitted helminths (STH) in a post-treatment setting in western Kenya. A cost analysis also explores the cost implications of collecting samples during school surveys when compared to household surveys. Methods Stool samples were collected from children (n = 652) attending 18 schools in Bungoma County and diagnosed by the Kato-Katz and Mini-FLOTAC coprological methods. Sensitivity and additional diagnostic performance measures were analyzed using Bayesian latent class modeling. Financial and economic costs were calculated for all survey and diagnostic activities, and cost per child tested, cost per case detected and cost per STH infection correctly classified were estimated. A sensitivity analysis was conducted to assess the impact of various survey parameters on cost estimates. Results Both diagnostic methods exhibited comparable sensitivity for detection of any STH species over single and consecutive day sampling: 52.0% for single day Kato-Katz; 49.1% for single-day Mini-FLOTAC; 76.9% for consecutive day Kato-Katz; and 74.1% for consecutive day Mini-FLOTAC. Diagnostic performance did not differ significantly between methods for the different STH species. Use of Kato-Katz with school-based sampling was the lowest cost scenario for cost per child tested ($10.14) and cost per case correctly classified ($12.84). Cost per case detected was lowest for Kato-Katz used in community-based sampling ($128.24). Sensitivity analysis revealed the cost of case detection for any STH decreased non-linearly as prevalence rates increased and was influenced by the number of samples collected. Conclusions The Kato-Katz method was comparable in diagnostic sensitivity to the Mini-FLOTAC method, but afforded greater cost-effectiveness. Future work is required to evaluate the cost-effectiveness of STH surveillance in different settings. PMID:24810593
Assefa, Liya M; Crellen, Thomas; Kepha, Stella; Kihara, Jimmy H; Njenga, Sammy M; Pullan, Rachel L; Brooker, Simon J
2014-05-01
This study evaluates the diagnostic accuracy and cost-effectiveness of the Kato-Katz and Mini-FLOTAC methods for detection of soil-transmitted helminths (STH) in a post-treatment setting in western Kenya. A cost analysis also explores the cost implications of collecting samples during school surveys when compared to household surveys. Stool samples were collected from children (n = 652) attending 18 schools in Bungoma County and diagnosed by the Kato-Katz and Mini-FLOTAC coprological methods. Sensitivity and additional diagnostic performance measures were analyzed using Bayesian latent class modeling. Financial and economic costs were calculated for all survey and diagnostic activities, and cost per child tested, cost per case detected and cost per STH infection correctly classified were estimated. A sensitivity analysis was conducted to assess the impact of various survey parameters on cost estimates. Both diagnostic methods exhibited comparable sensitivity for detection of any STH species over single and consecutive day sampling: 52.0% for single day Kato-Katz; 49.1% for single-day Mini-FLOTAC; 76.9% for consecutive day Kato-Katz; and 74.1% for consecutive day Mini-FLOTAC. Diagnostic performance did not differ significantly between methods for the different STH species. Use of Kato-Katz with school-based sampling was the lowest cost scenario for cost per child tested ($10.14) and cost per case correctly classified ($12.84). Cost per case detected was lowest for Kato-Katz used in community-based sampling ($128.24). Sensitivity analysis revealed the cost of case detection for any STH decreased non-linearly as prevalence rates increased and was influenced by the number of samples collected. The Kato-Katz method was comparable in diagnostic sensitivity to the Mini-FLOTAC method, but afforded greater cost-effectiveness. Future work is required to evaluate the cost-effectiveness of STH surveillance in different settings.
Blake, Diane R; Spielberg, Freya; Levy, Vivian; Lensing, Shelly; Wolff, Peter A; Venkatasubramanian, Lalitha; Acevedo, Nincoshka; Padian, Nancy; Chattopadhyay, Ishita; Gaydos, Charlotte A
2015-01-01
Results of a recent demonstration project evaluating feasibility, acceptability, and cost of a Web-based sexually transmitted infection (STI) testing and e-prescription treatment program (eSTI) suggest that this approach could be a feasible alternative to clinic-based testing and treatment, but the results need to be confirmed by a randomized comparative effectiveness trial. We modeled a decision tree comparing (1) cost of eSTI screening using a home collection kit and an e-prescription for uncomplicated treatment versus (2) hypothetical costs derived from the literature for referral to standard clinic-based STI screening and treatment. Primary outcome was number of STIs detected. Analyses were conducted from the clinical trial perspective and the health care system perspective. The eSTI strategy detected 75 infections, and the clinic referral strategy detected 45 infections. Total cost of eSTI was $94,938 ($1266/STI detected) from the clinical trial perspective and $96,088 ($1281/STI detected) from the health care system perspective. Total cost of clinic referral was $87,367 ($1941/STI detected) from the clinical trial perspective and $71,668 ($1593/STI detected) from the health care system perspective. Results indicate that eSTI will likely be more cost-effective (lower cost/STI detected) than clinic-based STI screening, both in the context of clinical trials and in routine clinical care. Although our results are promising, they are based on a demonstration project and estimates from other small studies. A comparative effectiveness research trial is needed to determine actual cost and impact of the eSTI system on identification and treatment of new infections and prevention of their sequelae.
Analysis of the development of missile-borne IR imaging detecting technologies
NASA Astrophysics Data System (ADS)
Fan, Jinxiang; Wang, Feng
2017-10-01
Today's infrared imaging guiding missiles are facing many challenges. With the development of targets' stealth, new-style IR countermeasures and penetrating technologies as well as the complexity of the operational environments, infrared imaging guiding missiles must meet the higher requirements of efficient target detection, capability of anti-interference and anti-jamming and the operational adaptability in complex, dynamic operating environments. Missileborne infrared imaging detecting systems are constrained by practical considerations like cost, size, weight and power (SWaP), and lifecycle requirements. Future-generation infrared imaging guiding missiles need to be resilient to changing operating environments and capable of doing more with fewer resources. Advanced IR imaging detecting and information exploring technologies are the key technologies that affect the future direction of IR imaging guidance missiles. Infrared imaging detecting and information exploring technologies research will support the development of more robust and efficient missile-borne infrared imaging detecting systems. Novelty IR imaging technologies, such as Infrared adaptive spectral imaging, are the key to effectively detect, recognize and track target under the complicated operating and countermeasures environments. Innovative information exploring techniques for the information of target, background and countermeasures provided by the detection system is the base for missile to recognize target and counter interference, jamming and countermeasure. Modular hardware and software development is the enabler for implementing multi-purpose, multi-function solutions. Uncooled IRFPA detectors and High-operating temperature IRFPA detectors as well as commercial-off-the-shelf (COTS) technology will support the implementing of low-cost infrared imaging guiding missiles. In this paper, the current status and features of missile-borne IR imaging detecting technologies are summarized. The key technologies and its development trends of missiles' IR imaging detecting technologies are analyzed.
Detecting and treating occlusal caries lesions: a cost-effectiveness analysis.
Schwendicke, F; Stolpe, M; Meyer-Lueckel, H; Paris, S
2015-02-01
The health gains and costs resulting from using different caries detection strategies might not only depend on the accuracy of the used method but also the treatment emanating from its use in different populations. We compared combinations of visual-tactile, radiographic, or laser-fluorescence-based detection methods with 1 of 3 treatments (non-, micro-, and invasive treatment) initiated at different cutoffs (treating all or only dentinal lesions) in populations with low or high caries prevalence. A Markov model was constructed to follow an occlusal surface in a permanent molar in an initially 12-y-old male German patient over his lifetime. Prevalence data and transition probabilities were extracted from the literature, while validity parameters of different methods were synthesized or obtained from systematic reviews. Microsimulations were performed to analyze the model, assuming a German health care setting and a mixed public-private payer perspective. Radiographic and fluorescence-based methods led to more overtreatments, especially in populations with low prevalence. For the latter, combining visual-tactile or radiographic detection with microinvasive treatment retained teeth longest (mean 66 y) at lowest costs (329 and 332 Euro, respectively), while combining radiographic or fluorescence-based detections with invasive treatment was the least cost-effective (<60 y, >700 Euro). In populations with high prevalence, combining radiographic detection with microinvasive treatment was most cost-effective (63 y, 528 Euro), while sensitive detection methods combined with invasive treatments were again the least cost-effective (<59 y, >690 Euro). The suitability of detection methods differed significantly between populations, and the cost-effectiveness was greatly influenced by the treatment initiated after lesion detection. The accuracy of a detection method relative to a "gold standard" did not automatically convey into better health or reduced costs. Detection methods should be evaluated not only against their criterion validity but also the long-term effects resulting from their use in different populations. © International & American Associations for Dental Research 2014.
Cost-effectiveness of prenatal screening strategies for congenital heart disease.
Pinto, N M; Nelson, R; Puchalski, M; Metz, T D; Smith, K J
2014-07-01
The economic implications of strategies to improve prenatal screening for congenital heart disease (CHD) in low-risk mothers have not been explored. The aim was to perform a cost-effectiveness analysis of different screening methods. We constructed a decision analytic model of CHD prenatal screening strategies (four-chamber screen (4C), 4C + outflow, nuchal translucency (NT) or fetal echocardiography) populated with probabilities from the literature. The model included whether initial screens were interpreted by a maternal-fetal medicine (MFM) specialist and different referral strategies if they were read by a non-MFM specialist. The primary outcome was the incremental cost per defect detected. Costs were obtained from Medicare National Fee estimates. A probabilistic sensitivity analysis was undertaken on model variables commensurate with their degree of uncertainty. In base-case analysis, 4C + outflow referred to an MFM specialist was the least costly strategy per defect detected. The 4C screen and the NT screen were dominated by other strategies (i.e. were more costly and less effective). Fetal echocardiography was the most effective, but most costly. On simulation of 10 000 low-risk pregnancies, 4C + outflow screen referred to an MFM specialist remained the least costly per defect detected. For an additional $580 per defect detected, referral to cardiology after a 4C + outflow was the most cost-effective for the majority of iterations, increasing CHD detection by 13 percentage points. The addition of examination of the outflow tracts to second-trimester ultrasound increases detection of CHD in the most cost-effective manner. Strategies to improve outflow-tract imaging and to refer with the most efficiency may be the best way to improve detection at a population level. Copyright © 2013 ISUOG. Published by John Wiley & Sons Ltd.
NASA Astrophysics Data System (ADS)
Jin, Yan; Gao, Anran; Jin, Qinghui; Li, Tie; Wang, Yuelin; Zhao, Jianlong
2018-04-01
In this paper, ultra-sensitive and highly selective Hg2+ detection in aqueous solutions was studied by free-standing silicon nanowire (SiNW) sensors. The all-around surface of SiNW arrays was functionalized with (3-Mercaptopropyl)trimethoxysilane serving as Hg2+ sensitive layer. Due to effective electrostatic control provided by the free-standing structure, a detection limit as low as 1 ppt was obtained. A linear relationship (R 2 = 0.9838) between log(CHg2+ ) and a device current change from 1 ppt to 5 ppm was observed. Furthermore, the developed SiNW sensor exhibited great selectivity for Hg2+ over other heavy metal ions, including Cd2+. Given the extraordinary ability for real-time Hg2+ detection, the small size and low cost of the SiNW device, it is expected to be a potential candidate in field detection of environmentally toxic mercury.
“UTILIZING” SIGNAL DETECTION THEORY
Lynn, Spencer K.; Barrett, Lisa Feldman
2014-01-01
What do inferring what a person is thinking or feeling, deciding to report a symptom to your doctor, judging a defendant’s guilt, and navigating a dimly lit room have in common? They involve perceptual uncertainty (e.g., a scowling face might indicate anger or concentration, which engender different appropriate responses), and behavioral risk (e.g., a cost to making the wrong response). Signal detection theory describes these types of decisions. In this tutorial we show how, by incorporating the economic concept of utility, signal detection theory serves as a model of optimal decision making, beyond its common use as an analytic method. This utility approach to signal detection theory highlights potentially enigmatic influences of perceptual uncertainty on measures of decision-making performance (accuracy and optimality) and on behavior (a functional relationship between bias and sensitivity). A “utilized” signal detection theory offers the possibility of expanding the phenomena that can be understood within a decision-making framework. PMID:25097061
DNAzyme based gap-LCR detection of single-nucleotide polymorphism.
Zhou, Li; Du, Feng; Zhao, Yongyun; Yameen, Afshan; Chen, Haodong; Tang, Zhuo
2013-07-15
Fast and accurate detection of single-nucleotide polymorphism (SNP) is thought more and more important for understanding of human physiology and elucidating the molecular based diseases. A great deal of effort has been devoted to developing accurate, rapid, and cost-effective technologies for SNP analysis. However most of those methods developed to date incorporate complicated probe labeling and depend on advanced equipment. The DNAzyme based Gap-LCR detection method averts any chemical modification on probes and circumvents those problems by incorporating a short functional DNA sequence into one of LCR primers. Two kinds of exonuclease are utilized in our strategy to digest all the unreacted probes and release the DNAzymes embedded in the LCR product. The DNAzyme applied in our method is a versatile tool to report the result of SNP detection in colorimetric or fluorometric ways for different detection purposes. Copyright © 2013 Elsevier B.V. All rights reserved.
From functional structure to packaging: full-printing fabrication of a microfluidic chip.
Zheng, Fengyi; Pu, Zhihua; He, Enqi; Huang, Jiasheng; Yu, Bocheng; Li, Dachao; Li, Zhihong
2018-05-24
This paper presents a concept of a full-printing methodology aiming at convenient and fast fabrication of microfluidic devices. For the first time, we achieved a microfluidic biochemical sensor with all functional structures fabricated by inkjet printing, including electrodes, immobilized enzymes, microfluidic components and packaging. With the cost-effective and rapid process, this method provides the possibility of quick model validation of a novel lab-on-chip system. In this study, a three-electrode electrochemical system was integrated successfully with glucose oxidase immobilization gel and sealed in an ice channel, forming a disposable microfluidic sensor for glucose detection. This fully-printed chip was characterized and showed good sensitivity and a linear section at a low-level concentration of glucose (0-10 mM). With the aid of automatic equipment, the fully-printed sensor can be massively produced with low cost.
Gold nanoparticles based colorimetric nanodiagnostics for cancer and infectious diseases
NASA Astrophysics Data System (ADS)
Valentini, Paola; Persano, Stefano; Cecere, Paola; Sabella, Stefania; Pompa, Pier Paolo
2014-03-01
Traditional in vitro diagnostics requires specialized laboratories and costly instrumentation, both for the amplification of nucleic acid targets (usually achieved by PCR) and for the assay readout, often based on fluorescence. We are developing hybrid nanomaterials-based sensors for the rapid and low-cost diagnosis of various disease biomarkers, for applications in portable platforms for diagnostics at the point-of-care. To this aim, we exploited the size and distancedependent optical properties of gold nanoparticles (AuNPs) to achieve colorimetric detection. Moreover, in order to avoid the complexity of thermal cycles associated to traditional PCR, the design of our systems includes signal amplification schemes, achieved by the use of enzymes (nucleases, helicase) or DNAzymes. Focused on instrument-free and sensitive detection, we carefully combined the intrinsic sensitivity by multivalency of functionalized AuNPs with isothermal and non-stringent enzyme-aided reaction conditions, controlled AuNPs aggregates, universal reporters and magnetic microparticles, the latter used both as a substrate and as a means for the colorimetric detection. We obtained simple and robust assays for the sensitive (pM range or better) naked-eye detection of cancer or infectious diseases (HPV, HCV) biomarkers, requiring no instrumentation except for a simple heating plate. Finally, we are also developing non-medical applications of these bio-nanosensors, such as in the development of on-field rapid tests for the detection of pollutants and other food and water contaminants.
NASA Astrophysics Data System (ADS)
Hou, Ligang; Luo, Rengui; Wu, Wuchen
2006-11-01
This paper forwards a low power grating detection chip (EYAS) on length and angle precision measurement. Traditional grating detection method, such as resister chain divide or phase locked divide circuit are difficult to design and tune. The need of an additional CPU for control and display makes these methods' implementation more complex and costly. Traditional methods also suffer low sampling speed for the complex divide circuit scheme and CPU software compensation. EYAS is an application specific integrated circuit (ASIC). It integrates micro controller unit (MCU), power management unit (PMU), LCD controller, Keyboard interface, grating detection unit and other peripherals. Working at 10MHz, EYAS can afford 5MHz internal sampling rate and can handle 1.25MHz orthogonal signal from grating sensor. With a simple control interface by keyboard, sensor parameter, data processing and system working mode can be configured. Two LCD controllers can adapt to dot array LCD or segment bit LCD, which comprised output interface. PMU alters system between working and standby mode by clock gating technique to save power. EYAS in test mode (system action are more frequently than real world use) consumes 0.9mw, while 0.2mw in real world use. EYAS achieved the whole grating detection system function, high-speed orthogonal signal handling in a single chip with very low power consumption.
Hybrid nanosensor for colorimetric and ultrasensitive detection of nuclease contaminations
NASA Astrophysics Data System (ADS)
Cecere, Paola; Valentini, Paola; Pompa, Pier Paolo
2016-04-01
Nucleases are ubiquitous enzymes that degrade DNA or RNA, thus they can prejudice the good outcome of molecular biology experiments involving nucleic acids. We propose a colorimetric test for the naked-eye detection of nuclease contaminations. The system uses an hybrid nanosensor, based on gold nanoparticles functionalized with DNA probes. Our assay is rapid, instrument-free, simple and low-cost. Moreover, it reaches sensitivity equal or better than those of commercial kits, and presents a lot of advantageous aspects. Therefore, it is very competitive, with a real market potential. This test will be relevant in routine process monitoring in scientific laboratories, and in quality control in clinical laboratories and industrial processes, allowing the simultaneous detection of nucleases with different substrate specificities and large-scale screening.
Index to Estimate the Efficiency of an Ophthalmic Practice.
Chen, Andrew; Kim, Eun Ah; Aigner, Dennis J; Afifi, Abdelmonem; Caprioli, Joseph
2015-08-01
A metric of efficiency, a function of the ratio of quality to cost per patient, will allow the health care system to better measure the impact of specific reforms and compare the effectiveness of each. To develop and evaluate an efficiency index that estimates the performance of an ophthalmologist's practice as a function of cost, number of patients receiving care, and quality of care. Retrospective review of 36 ophthalmology subspecialty practices from October 2011 to September 2012 at a university-based eye institute. The efficiency index (E) was defined as a function of adjusted number of patients (N(a)), total practice adjusted costs (C(a)), and a preliminary measure of quality (Q). Constant b limits E between 0 and 1. Constant y modifies the influence of Q on E. Relative value units and geographic cost indices determined by the Centers for Medicare and Medicaid for 2012 were used to calculate adjusted costs. The efficiency index is expressed as the following: E = b(N(a)/C(a))Q(y). Independent, masked auditors reviewed 20 random patient medical records for each practice and filled out 3 questionnaires to obtain a process-based quality measure. The adjusted number of patients, adjusted costs, quality, and efficiency index were calculated for 36 ophthalmology subspecialties. The median adjusted number of patients was 5516 (interquartile range, 3450-11,863), the median adjusted cost was 1.34 (interquartile range, 0.99-1.96), the median quality was 0.89 (interquartile range, 0.79-0.91), and the median value of the efficiency index was 0.26 (interquartile range, 0.08-0.42). The described efficiency index is a metric that provides a broad overview of performance for a variety of ophthalmology specialties as estimated by resources used and a preliminary measure of quality of care provided. The results of the efficiency index could be used in future investigations to determine its sensitivity to detect the impact of interventions on a practice such as training modules or practice restructuring.
Multi-functional photonic crystal sensors enabled by biological silica (Conference Presentation)
NASA Astrophysics Data System (ADS)
Wang, Alan X.
2017-02-01
Diatoms are microalgae found in every habitat where water is present. They produce 40% of the ocean's yearly production of organic carbon and 20% of the oxygen that we breathe. Their abundance and wide distribution make them ideal materials for a wide range of applications as living organisms. In our previous work, we have demonstrated that diatom biosilica with self-assembled silver nanoparticles (Ag NPs) can be used as ultra-sensitive, low-cost substrates for surface-enhanced Raman scattering (SERS) sensing. The enhancement comes from the photonic crystal enhancement of diatom frustules that could improve the hot-spots of Ag NPs. In this work, we report the unique micro-fluidic flow, analyte concentration effect, and thin layer chromatography (TLC) on diatom biosilica, which enables selection, separation, detection, and analysis of complex chemical and biological samples. Particularly, we show that the microscopic fluidic flow induced by the evaporation of liquid droplet can concentrate the analyte and achieve label-free sensing of single molecule detection of R6G and label-free sensing of 4.5×10-17g trinitrotoluene (TNT) from only 200 nano-liter solution. We also demonstrated a facile method for instant on-site separation and detection of analytes by TLC in tandem with SERS spectroscopy using high density diatom thin film. This lab-on-chip technology has been successfully applied for label-free detection of polycyclic aromatic hydrocarbons from human plasma and histamine from salmon fish. Our research suggests that such cost-effective, multi-functional photonic crystal sensors enabled by diatom biosilica opens a new route for lab-on-chip systems and possess significant engineering potentials for chemical and biological sensing.
NASA Technical Reports Server (NTRS)
Abdul-Aziz, Ali; Baaklini, George Y.; Roth, Don J.
2004-01-01
Engine makers and aviation safety government institutions continue to have a strong interest in monitoring the health of rotating components in aircraft engines to improve safety and to lower maintenance costs. To prevent catastrophic failure (burst) of the engine, they use nondestructive evaluation (NDE) and major overhauls for periodic inspections to discover any cracks that might have formed. The lowest cost fluorescent penetrant inspection NDE technique can fail to disclose cracks that are tightly closed during rest or that are below the surface. The NDE eddy current system is more effective at detecting both crack types, but it requires careful setup and operation and only a small portion of the disk can be practically inspected. So that sensor systems can sustain normal function in a severe environment, health-monitoring systems require the sensor system to transmit a signal if a crack detected in the component is above a predetermined length (but below the length that would lead to failure) and lastly to act neutrally upon the overall performance of the engine system and not interfere with engine maintenance operations. Therefore, more reliable diagnostic tools and high-level techniques for detecting damage and monitoring the health of rotating components are very essential in maintaining engine safety and reliability and in assessing life.
Health management and controls for Earth-to-orbit propulsion systems
NASA Astrophysics Data System (ADS)
Bickford, R. L.
1995-03-01
Avionics and health management technologies increase the safety and reliability while decreasing the overall cost for Earth-to-orbit (ETO) propulsion systems. New ETO propulsion systems will depend on highly reliable fault tolerant flight avionics, advanced sensing systems and artificial intelligence aided software to ensure critical control, safety and maintenance requirements are met in a cost effective manner. Propulsion avionics consist of the engine controller, actuators, sensors, software and ground support elements. In addition to control and safety functions, these elements perform system monitoring for health management. Health management is enhanced by advanced sensing systems and algorithms which provide automated fault detection and enable adaptive control and/or maintenance approaches. Aerojet is developing advanced fault tolerant rocket engine controllers which provide very high levels of reliability. Smart sensors and software systems which significantly enhance fault coverage and enable automated operations are also under development. Smart sensing systems, such as flight capable plume spectrometers, have reached maturity in ground-based applications and are suitable for bridging to flight. Software to detect failed sensors has reached similar maturity. This paper will discuss fault detection and isolation for advanced rocket engine controllers as well as examples of advanced sensing systems and software which significantly improve component failure detection for engine system safety and health management.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rhee, Seung; Spencer, Cherrill; /Stanford U. /SLAC
2009-01-23
Failure occurs when one or more of the intended functions of a product are no longer fulfilled to the customer's satisfaction. The most critical product failures are those that escape design reviews and in-house quality inspection and are found by the customer. The product may work for a while until its performance degrades to an unacceptable level or it may have not worked even before customer took possession of the product. The end results of failures which may lead to unsafe conditions or major losses of the main function are rated high in severity. Failure Modes and Effects Analysis (FMEA)more » is a tool widely used in the automotive, aerospace, and electronics industries to identify, prioritize, and eliminate known potential failures, problems, and errors from systems under design, before the product is released (Stamatis, 1997). Several industrial FMEA standards such as those published by the Society of Automotive Engineers, US Department of Defense, and the Automotive Industry Action Group employ the Risk Priority Number (RPN) to measure risk and severity of failures. The Risk Priority Number (RPN) is a product of 3 indices: Occurrence (O), Severity (S), and Detection (D). In a traditional FMEA process design engineers typically analyze the 'root cause' and 'end-effects' of potential failures in a sub-system or component and assign penalty points through the O, S, D values to each failure. The analysis is organized around categories called failure modes, which link the causes and effects of failures. A few actions are taken upon completing the FMEA worksheet. The RPN column generally will identify the high-risk areas. The idea of performing FMEA is to eliminate or reduce known and potential failures before they reach the customers. Thus, a plan of action must be in place for the next task. Not all failures can be resolved during the product development cycle, thus prioritization of actions must be made within the design group. One definition of detection difficulty (D) is how well the organization controls the development process. Another definition relates to the detectability of a particular failure in the product when it is in the hands of the customer. The former asks 'What is the chance of catching the problem before we give it to the customer'? The latter asks 'What is the chance of the customer catching the problem before the problem results in a catastrophic failure?' (Palady, 1995) These differing definitions confuse the FMEA users when one tries to determine detection difficulty. Are we trying to measure how easy it is to detect where a failure has occurred or when it has occurred? Or are we trying to measure how easy or difficult it is to prevent failures? Ordinal scale variables are used to rank-order industries such as, hotels, restaurants, and movies (Note that a 4 star hotel is not necessarily twice as good as a 2 star hotel). Ordinal values preserve rank in a group of items, but the distance between the values cannot be measured since a distance function does not exist. Thus, the product or sum of ordinal variables loses its rank since each parameter has different scales. The RPN is a product of 3 independent ordinal variables, it can indicate that some failure types are 'worse' than others, but give no quantitative indication of their relative effects. To resolve the ambiguity of measuring detection difficulty and the irrational logic of multiplying 3 ordinal indices, a new methodology was created to overcome these shortcomings, Life Cost-Based FMEA. Life Cost-Based FMEA measures failure/risk in terms of monetary cost. Cost is a universal parameter that can be easily related to severity by engineers and others. Thus, failure cost can be estimated using the following simplest form: Expected Failure Cost = {sup n}{Sigma}{sub i=1}p{sub i}c{sub i}, p: Probability of a particular failure occurring; c: Monetary cost associated with that particular failure; and n: Total number of failure scenarios. FMEA is most effective when there are inputs into it from all concerned disciplines of the product development team. However, FMEA is a long process and can become tedious and won't be effective if too many people participate. An ideal team should have 3 to 4 people from: design, manufacturing, and service departments if possible. Depending on how complex the system is, the entire process can take anywhere from one to four weeks working full time. Thus, it is important to agree to the time commitment before starting the analysis else, anxious managers might stop the procedure before it is completed.« less
Pagès, Arnaud; Iriart, Xavier; Molinier, Laurent; Georges, Bernard; Berry, Antoine; Massip, Patrice; Juillard-Condat, Blandine
2017-12-01
Mortality from intra-abdominal candidiasis in intensive care units (ICUs) is high. It takes many days for peritoneal-fluid fungal culture to become positive, and the recommended empirical antifungal therapy involves excessive costs. Polymerase chain reaction (PCR) should produce results more rapidly than fungal culture. To perform a cost-effectiveness analysis of the combination of several diagnostic and therapeutic strategies to manage Candida peritonitis in non-neutropenic adult patients in ICUs. We constructed a decision tree model to evaluate the cost effectiveness. Cost and effectiveness were taken into account in a 1-year time horizon and from the French National Health Insurance perspective. Six strategies were compared: fluconazole or echinocandin as an empirical therapy, plus diagnosis by fungal culture or detection by PCR of all Candida species, or use of PCR to detect most fluconazole-resistant Candida species (i.e., Candida krusei and Candida glabrata). The use of fluconazole empirical treatment and PCR to detect all Candida species is more cost effective than using fluconazole empirical treatment without PCR (incremental cost-effectiveness ratio of €40,055/quality-adjusted life-year). Empirical treatment with echinocandin plus PCR to detect C. krusei and C. glabrata is the most effective strategy, but has an incremental cost-effectiveness ratio of €93,776/quality-adjusted life-year. If the cost of echinocandin decreases, then strategies involving PCR plus empirical echinocandin become more cost-effective. Detection by PCR of all Candida species and of most fluconazole-resistant Candida species could improve the cost-effectiveness of fluconazole and echinocandin given to non-neutropenic patients with suspected peritoneal candidiasis in ICUs. Copyright © 2017 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.
Hahm, Jong-in
2011-01-01
The rapidly growing field of proteomics and related applied sectors in the life sciences demands convenient methodologies for detecting and measuring the levels of specific proteins as well as for screening and analyzing for interacting protein systems. Materials utilized for such protein detection and measurement platforms should meet particular specifications which include ease-of-mass manufacture, biological stability, chemical functionality, cost effectiveness, and portability. Polymers can satisfy many of these requirements and are often considered as choice materials in various biological detection platforms. Therefore, tremendous research efforts have been made for developing new polymers both in macroscopic and nanoscopic length scales as well as applying existing polymeric materials for protein measurements. In this review article, both conventional and alternative techniques for protein detection are overviewed while focusing on the use of various polymeric materials in different protein sensing technologies. Among many available detection mechanisms, most common approaches such as optical, electrochemical, electrical, mass-sensitive, and magnetic methods are comprehensively discussed in this article. Desired properties of polymers exploited for each type of protein detection approach are summarized. Current challenges associated with the application of polymeric materials are examined in each protein detection category. Difficulties facing both quantitative and qualitative protein measurements are also identified. The latest efforts on the development and evaluation of nanoscale polymeric systems for improved protein detection are also discussed from the standpoint of quantitative and qualitative measurements. Finally, future research directions towards further advancements in the field are considered. PMID:21691441
Pereiro, Iago; Bendali, Amel; Tabnaoui, Sanae; Alexandre, Lucile; Srbova, Jana; Bilkova, Zuzana; Deegan, Shane; Joshi, Lokesh; Viovy, Jean-Louis; Malaquin, Laurent
2017-01-01
A microfluidic method to specifically capture and detect infectious bacteria based on immunorecognition and proliferative power is presented. It involves a microscale fluidized bed in which magnetic and drag forces are balanced to retain antibody-functionalized superparamagnetic beads in a chamber during sample perfusion. Captured cells are then cultivated in situ by infusing nutritionally-rich medium. The system was validated by the direct one-step detection of Salmonella Typhimurium in undiluted unskimmed milk, without pre-treatment. The growth of bacteria induces an expansion of the fluidized bed, mainly due to the volume occupied by the newly formed bacteria. This expansion can be observed with the naked eye, providing simple low-cost detection of only a few bacteria and in a few hours. The time to expansion can also be measured with a low-cost camera, allowing quantitative detection down to 4 cfu (colony forming unit), with a dynamic range of 100 to 107 cfu ml–1 in 2 to 8 hours, depending on the initial concentration. This mode of operation is an equivalent of quantitative PCR, with which it shares a high dynamic range and outstanding sensitivity and specificity, operating at the live cell rather than DNA level. Specificity was demonstrated by controls performed in the presence of a 500× excess of non-pathogenic Lactococcus lactis. The system's versatility was demonstrated by its successful application to the detection and quantitation of Escherichia coli O157:H15 and Enterobacter cloacae. This new technology allows fast, low-cost, portable and automated bacteria detection for various applications in food, environment, security and clinics. PMID:28626552
Costa, M N; Veigas, B; Jacob, J M; Santos, D S; Gomes, J; Baptista, P V; Martins, R; Inácio, J; Fortunato, E
2014-03-07
There is a strong interest in the use of biopolymers in the electronic and biomedical industries, mainly towards low-cost applications. The possibility of developing entirely new kinds of products based on cellulose is of current interest, in order to enhance and to add new functionalities to conventional paper-based products. We present our results towards the development of paper-based microfluidics for molecular diagnostic testing. Paper properties were evaluated and compared to nitrocellulose, the most commonly used material in lateral flow and other rapid tests. Focusing on the use of paper as a substrate for microfluidic applications, through an eco-friendly wax-printing technology, we present three main and distinct colorimetric approaches: (i) enzymatic reactions (glucose detection); (ii) immunoassays (antibodies anti-Leishmania detection); (iii) nucleic acid sequence identification (Mycobacterium tuberculosis complex detection). Colorimetric glucose quantification was achieved through enzymatic reactions performed within specific zones of the paper-based device. The colouration achieved increased with growing glucose concentration and was highly homogeneous, covering all the surface of the paper reaction zones in a 3D sensor format. These devices showed a major advantage when compared to the 2D lateral flow glucose sensors, where some carryover of the coloured products usually occurs. The detection of anti-Leishmania antibodies in canine sera was conceptually achieved using a paper-based 96-well enzyme-linked immunosorbent assay format. However, optimization is still needed for this test, regarding the efficiency of the immobilization of antigens on the cellulose fibres. The detection of Mycobacterium tuberculosis nucleic acids integrated with a non-cross-linking gold nanoprobe detection scheme was also achieved in a wax-printed 384-well paper-based microplate, by the hybridization with a species-specific probe. The obtained results with the above-mentioned proof-of-concept sensors are thus promising towards the future development of simple and cost-effective paper-based diagnostic devices.
NASA Astrophysics Data System (ADS)
Costa, M. N.; Veigas, B.; Jacob, J. M.; Santos, D. S.; Gomes, J.; Baptista, P. V.; Martins, R.; Inácio, J.; Fortunato, E.
2014-03-01
There is a strong interest in the use of biopolymers in the electronic and biomedical industries, mainly towards low-cost applications. The possibility of developing entirely new kinds of products based on cellulose is of current interest, in order to enhance and to add new functionalities to conventional paper-based products. We present our results towards the development of paper-based microfluidics for molecular diagnostic testing. Paper properties were evaluated and compared to nitrocellulose, the most commonly used material in lateral flow and other rapid tests. Focusing on the use of paper as a substrate for microfluidic applications, through an eco-friendly wax-printing technology, we present three main and distinct colorimetric approaches: (i) enzymatic reactions (glucose detection); (ii) immunoassays (antibodies anti-Leishmania detection); (iii) nucleic acid sequence identification (Mycobacterium tuberculosis complex detection). Colorimetric glucose quantification was achieved through enzymatic reactions performed within specific zones of the paper-based device. The colouration achieved increased with growing glucose concentration and was highly homogeneous, covering all the surface of the paper reaction zones in a 3D sensor format. These devices showed a major advantage when compared to the 2D lateral flow glucose sensors, where some carryover of the coloured products usually occurs. The detection of anti-Leishmania antibodies in canine sera was conceptually achieved using a paper-based 96-well enzyme-linked immunosorbent assay format. However, optimization is still needed for this test, regarding the efficiency of the immobilization of antigens on the cellulose fibres. The detection of Mycobacterium tuberculosis nucleic acids integrated with a non-cross-linking gold nanoprobe detection scheme was also achieved in a wax-printed 384-well paper-based microplate, by the hybridization with a species-specific probe. The obtained results with the above-mentioned proof-of-concept sensors are thus promising towards the future development of simple and cost-effective paper-based diagnostic devices.
Optical Metrology for CIGS Solar Cell Manufacturing and its Cost Implications
NASA Astrophysics Data System (ADS)
Sunkoju, Sravan Kumar
Solar energy is a promising source of renewable energy which can meet the demand for clean energy in near future with advances in research in the field of photovoltaics and cost reduction by commercialization. Availability of a non-contact, in-line, real time robust process control strategies can greatly aid in reducing the gap between cell and module efficiencies, thereby leading to cost-effective large-scale manufacturing of high efficiency CIGS solar cells. In order to achieve proper process monitoring and control for the deposition of the functional layers of CuIn1-xGaxSe 2 (CIGS) based thin film solar cell, optical techniques such as spectroscopic reflectometry and polarimetry are advantageous because they can be set up in an unobtrusive manner in the manufacturing line, and collect data in-line and in-situ. The use of these techniques requires accurate optical models that correctly represent the properties of the layers being deposited. In this study, Spectroscopic ellipsometry (SE) has been applied for the characterization of each individual stage of CIGS layers deposited using the 3-stage co-evaporation process along with the other functional layers. Dielectric functions have been determined for the energy range from 0.7 eV to 5.1 eV. Critical-point line-shape analysis was used in this study to determine the critical point energies of the CIGS based layers. To control the compositional and thickness uniformity of all the functional layers during the fabrication of CIGS solar cells over large areas, multilayer photovoltaics (PV) stack optical models were developed with the help of extracted dielectric functions. In this study, mapping capability of RC2 spectroscopic ellipsometer was used to map all the functional layer thicknesses of a CIGS solar cell in order to probe the spatial non-uniformities that can affect the performance of a cell. The optical functions for each of the stages of CIGS 3-stage deposition process along with buffer layer and transparent conducting oxide (TCO) bi-layer, thus derived were used in a fiber optic-based spectroscopic reflectometry optical monitoring system installed in the pilot line at the PVMC's Halfmoon facility. Results obtained from this study show that the use of regular fiber optics, instead of polarization-maintaining fiber optics, is sufficient for the purpose of process monitoring. Also, the technique does not need to be used "in-situ", but the measurements can be taken in-line, and are applicable to a variety of deposition techniques used for different functional layers deposited on rigid or flexible substrates. In addition, effect of Cu concentration on the CIGS optical properties has been studied. Mixed CIGS/Cu2-xSe phase was observed at the surface at the end of the second stage of 3-stage deposition process, under Cu-rich conditions. A significant change in optical behavior of CIGS due to Cu2-xSe at the surface was observed under Cu-rich conditions, which can be used as end-point detection method to move from 2nd stage to 3rd stage in the deposition process. Developed optical functions were applied to in-line reflectance measurements not only to identify the Cu2-xSe phase at the surface but also to measure the thickness of the mixed CIGS/Cu2-xSe layer. This spectroscopic reflectometry based in-line process control technique can be used for end-point detection as well as to control thickness during the preparation of large area CIGS films. These results can assist in the development of optical process-control tools for the manufacturing of high quality CIGS based photovoltaic cells, increasing the uptime and yield of the production line. Finally, to understand the cost implications, low cost potential of two different deposition technologies has been studied on both rigid and flexible substrates with the help of cost analysis. Cost advantages of employing a contactless optics based process control technique have been investigated in order to achieve a low cost of < 0.5 $/W for CIGS module production. Based on cost analysis, one of the best strategies for achieving the low cost targets would be increasing manufacturing throughput, using roll-to-roll thin-film module manufacturing, with co-evaporation and chemical bath deposition processes for absorber and buffer layer respectively, while applying a low-cost process control technique such as spectroscopic reflectometry to improve module efficiencies and maintain high yield.
SpiderSpec: a low-cost compact colorimeter with IoT functionality
NASA Astrophysics Data System (ADS)
Mignani, Anna G.; Mencaglia, Andrea A.; Baldi, Massimo; Ciaccheri, Leonardo
2015-07-01
A miniaturized device for colorimetry is presented that utilizes a LED array for illumination and a compact spectrometer for detection. It can be battery-powered, operated locally as a stand-alone device, or connected via wi-fi to the internet. It has potentials to be remotely operated by means of a tablet or a smartphone. In practice, it consists of a low-cost hardware configuration that is adaptable via software to the user's most varied requests, as a spectroscopic platform appropriate for a variety of applications. The hardware and software modules can be designed with different performances, complexities and costs, with the aim of making the colorimeter a device for Internet-of-Things use. It will be suitable for a selected range of consumer applications, as well as for targeted industrial, environmental, and food applications.
Al-Shaikhli, Saif Dawood Salman; Yang, Michael Ying; Rosenhahn, Bodo
2016-12-01
This paper presents a novel method for Alzheimer's disease classification via an automatic 3D caudate nucleus segmentation. The proposed method consists of segmentation and classification steps. In the segmentation step, we propose a novel level set cost function. The proposed cost function is constrained by a sparse representation of local image features using a dictionary learning method. We present coupled dictionaries: a feature dictionary of a grayscale brain image and a label dictionary of a caudate nucleus label image. Using online dictionary learning, the coupled dictionaries are learned from the training data. The learned coupled dictionaries are embedded into a level set function. In the classification step, a region-based feature dictionary is built. The region-based feature dictionary is learned from shape features of the caudate nucleus in the training data. The classification is based on the measure of the similarity between the sparse representation of region-based shape features of the segmented caudate in the test image and the region-based feature dictionary. The experimental results demonstrate the superiority of our method over the state-of-the-art methods by achieving a high segmentation (91.5%) and classification (92.5%) accuracy. In this paper, we find that the study of the caudate nucleus atrophy gives an advantage over the study of whole brain structure atrophy to detect Alzheimer's disease. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Johns, Benjamin; Doroshenko, Olena; Tarantino, Lisa; Cowley, Peter
2017-03-01
We estimate the number of HIV cases diagnosed, costs, and cost per HIV case detected associated with integrating HIV counseling and testing (HCT) into primary health care facilities in Ukraine. The study uses a difference-in-difference design with four districts implementing the intervention compared to 20 districts where HCT were offered only at specialized HIV clinics. There was a 2.01 (95 % CI: 1.12-3.61) times increase in the number of HIV cases detected per capita in intervention districts compared to other districts. The incremental cost of the intervention was $21,017 and the incremental cost per HIV case detected was $369. The average cost per HIV case detected before the intervention was $558. Engaging primary health care facilities to provide HCT is likely desirable from an efficiency point-of-view. However, the affordability of the intervention needs to be assessed because expansion will require additional investment.
Pizzi, Laura T; Waisbourd, Michael; Hark, Lisa; Sembhi, Harjeet; Lee, Paul; Crews, John E; Saaddine, Jinan B; Steele, Deon; Katz, L Jay
2018-02-01
Glaucoma is the foremost cause of irreversible blindness, and more than 50% of cases remain undiagnosed. Our objective was to report the costs of a glaucoma detection programme operationalised through Philadelphia community centres. The analysis was performed using a healthcare system perspective in 2013 US dollars. Costs of examination and educational workshops were captured. Measures were total programme costs, cost/case of glaucoma detected and cost/case of any ocular disease detected (including glaucoma). Diagnoses are reported at the individual level (therefore representing a diagnosis made in one or both eyes). Staff time was captured during site visits to 15 of 43 sites and included time to deliver examinations and workshops, supervision, training and travel. Staff time was converted to costs by applying wage and fringe benefit costs from the US Bureau of Labor Statistics. Non-staff costs (equipment and mileage) were collected using study logs. Participants with previously diagnosed glaucoma were excluded. 1649 participants were examined. Mean total per-participant examination time was 56 min (SD 4). Mean total examination cost/participant was $139. The cost/case of glaucoma newly identified (open-angle glaucoma, angle-closure glaucoma, glaucoma suspect, or primary angle closure) was $420 and cost/case for any ocular disease identified was $273. Glaucoma examinations delivered through this programme provided significant health benefit to hard-to-reach communities. On a per-person basis, examinations were fairly low cost, though opportunities exist to improve efficiency. Findings serve as an important benchmark for planning future community-based glaucoma examination programmes. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
A quantum leap into the IED age
DOE Office of Scientific and Technical Information (OSTI.GOV)
Patterson, R.C.
1996-11-01
The integration of pattern recognition, artificial intelligence and advanced communication technologies in utility substation IED`s (Intelligent Electronic Devices) has opened the door to practical and cost effective automation of power distribution systems. A major driver for the application of these new technologies has been the research directed toward the detection of high-impedance faults. The commercial products which embody these complex detection functions have already expanded to include most of the protection, control, and monitoring required at a utility substation. These new Super-IED`s enable major utility initiatives, such as power quality management, improved public safety, operation and maintenance productivity, and powermore » system automation.« less
Low-Cost Chemical-Responsive Adhesive Sensing Chips.
Tan, Weirui; Zhang, Liyuan; Shen, Wei
2017-12-06
Chemical-responsive adhesive sensing chip is a new low-cost analytical platform that uses adhesive tape loaded with indicator reagents to detect or quantify the target analytes by directly sticking the tape to the samples of interest. The chemical-responsive adhesive sensing chips can be used with paper to analyze aqueous samples; they can also be used to detect and quantify solid, particulate, and powder analytes. The colorimetric indicators become immediately visible as the contact between the functionalized adhesives and target samples is made. The chemical-responsive adhesive sensing chip expands the capability of paper-based analytical devices to analyze solid, particulate, or powder materials via one-step operation. It is also a simpler alternative way, to the covalent chemical modification of paper, to eliminate indicator leaching from the dipstick-style paper sensors. Chemical-responsive adhesive chips can display analytical results in the form of colorimetric dot patterns, symbols, and texts, enabling clear understanding of assay results by even nonprofessional users. In this work, we demonstrate the analyses of heavy metal salts in silica powder matrix, heavy metal ions in water, and bovine serum albumin in an aqueous solution. The detection is one-step, specific, sensitive, and easy-to-operate.
Ding, Chao; Yang, Lijun; Wu, Meng
2017-01-01
Due to the unattended nature and poor security guarantee of the wireless sensor networks (WSNs), adversaries can easily make replicas of compromised nodes, and place them throughout the network to launch various types of attacks. Such an attack is dangerous because it enables the adversaries to control large numbers of nodes and extend the damage of attacks to most of the network with quite limited cost. To stop the node replica attack, we propose a location similarity-based detection scheme using deployment knowledge. Compared with prior solutions, our scheme provides extra functionalities that prevent replicas from generating false location claims without deploying resource-consuming localization techniques on the resource-constraint sensor nodes. We evaluate the security performance of our proposal under different attack strategies through heuristic analysis, and show that our scheme achieves secure and robust replica detection by increasing the cost of node replication. Additionally, we evaluate the impact of network environment on the proposed scheme through theoretic analysis and simulation experiments, and indicate that our scheme achieves effectiveness and efficiency with substantially lower communication, computational, and storage overhead than prior works under different situations and attack strategies. PMID:28098846
Ding, Chao; Yang, Lijun; Wu, Meng
2017-01-15
Due to the unattended nature and poor security guarantee of the wireless sensor networks (WSNs), adversaries can easily make replicas of compromised nodes, and place them throughout the network to launch various types of attacks. Such an attack is dangerous because it enables the adversaries to control large numbers of nodes and extend the damage of attacks to most of the network with quite limited cost. To stop the node replica attack, we propose a location similarity-based detection scheme using deployment knowledge. Compared with prior solutions, our scheme provides extra functionalities that prevent replicas from generating false location claims without deploying resource-consuming localization techniques on the resource-constraint sensor nodes. We evaluate the security performance of our proposal under different attack strategies through heuristic analysis, and show that our scheme achieves secure and robust replica detection by increasing the cost of node replication. Additionally, we evaluate the impact of network environment on the proposed scheme through theoretic analysis and simulation experiments, and indicate that our scheme achieves effectiveness and efficiency with substantially lower communication, computational, and storage overhead than prior works under different situations and attack strategies.
Xin, Yunhong; Wang, Qi; Liu, Taihong; Wang, Lingling; Li, Jia; Fang, Yu
2012-11-21
A multichannel fluorescence detector used to detect nitroaromatic explosives in aqueous phase has been developed, which is composed of a five-channel sample-sensor unit, a measurement and control unit, a microcontroller, and a communication unit. The characteristics of the detector as developed are mainly embedded in the sensor unit, and each sensor consists of a fluorescent sensing film, a light emitting diode (LED), a multi-pixel photon counter (MPPC), and an optical module with special bandpass optical filters. Due to the high sensitivity of the sensing film, the small size and low cost of LED and MPPC, the developed detector not only has a better detecting performance and small size, but also has a very low cost - it is an alternative to the device made with an expensive high power lamp and photomultiplier tube. The wavelengths of the five sensors covered extend from the upper UV through the visible spectrum, 370-640 nm, and thereby it possesses the potential to detect a variety of explosives and other hazardous materials in aqueous phase. An additional function of the detector is its ability to function via a wireless network, by which the data recorded by the detector can be sent to the host computer, and at the same time the instructions can be sent to the detector from the host computer. By means of the powerful computing ability of the host computer, and utilizing the classical principal component analysis (PCA) algorithm, effective classification of the analytes is achieved. Furthermore, the detector has been tested and evaluated using NB, PA, TNT and DNT as the analytes, and toluene, benzene, methanol and ethanol as interferent compounds (concentration various from 10 and 60 μM). It has been shown that the detector can detect the four nitroaromatics with high sensitivity and selectivity.
Jia, Xiaofang; Dong, Shaojun; Wang, Erkang
2016-02-15
Electrochemical biosensors have played active roles at the forefront of bioanalysis because they have the potential to achieve sensitive, specific and low-cost detection of biomolecules and many others. Engineering the electrochemical sensing interface with functional nanomaterials leads to novel electrochemical biosensors with improved performances in terms of sensitivity, selectivity, stability and simplicity. Functional nanomaterials possess good conductivity, catalytic activity, biocompatibility and high surface area. Coupled with bio-recognition elements, these features can amplify signal transduction and biorecognition events, resulting in highly sensitive biosensing. Additionally, microfluidic electrochemical biosensors have attracted considerable attention on account of their miniature, portable and low-cost systems as well as high fabrication throughput and ease of scaleup. For example, electrochemical enzymetic biosensors and aptamer biosensors (aptasensors) based on the integrated microchip can be used for portable point-of-care diagnostics and environmental monitoring. This review is a summary of our recent progress in the field of electrochemical biosensors, including aptasensors, cytosensors, enzymatic biosensors and self-powered biosensors based on biofuel cells. We presented the advantages that functional nanomaterials and microfluidic chip technology bring to the electrochemical biosensors, together with future prospects and possible challenges. Copyright © 2015 Elsevier B.V. All rights reserved.
A novel 6-DOF parallel robot and its pose errors compensation
NASA Astrophysics Data System (ADS)
Shi, Zhixin; Ye, Meiyan; Luo, Yufeng
2011-10-01
In the traditional security solution conditions, software firewall cannot intercept and respond the invasion before being attacked. And because of the high cost, the hardware firewall does not apply to the security strategy of the end nodes, so we have designed a kind of solution of embedded firewall with hardware and software. With ARM embedding Linux operating system, we have designed packet filter module and intrusion detection module to implement the basic function of firewall. Experiments and results show that that firewall has the advantages of low cost, high processing speed, high safety and the application of the computer terminals. This paper focuses on packet filtering module design and implementation.
Design and implement of pack filter module base on embedded firewall
NASA Astrophysics Data System (ADS)
Tian, Libo; Wang, Chen; Yang, Shunbo
2011-10-01
In the traditional security solution conditions, software firewall cannot intercept and respond the invasion before being attacked. And because of the high cost, the hardware firewall does not apply to the security strategy of the end nodes, so we have designed a kind of solution of embedded firewall with hardware and software. With ARM embedding Linux operating system, we have designed packet filter module and intrusion detection module to implement the basic function of firewall. Experiments and results show that that firewall has the advantages of low cost, high processing speed, high safety and the application of the computer terminals. This paper focuses on packet filtering module design and implementation.
Berry, Colin; Zimmerli, Lukas U; Steedman, Tracey; Foster, John E; Dargie, Henry J; Berg, Geoffrey A; Dominiczak, Anna F; Delles, Christian
2008-03-01
Morbidity following CABG (coronary artery bypass grafting) is difficult to predict and leads to increased healthcare costs. We hypothesized that pre-operative CMR (cardiac magnetic resonance) findings would predict resource utilization in elective CABG. Over a 12-month period, patients requiring elective CABG were invited to undergo CMR 1 day prior to CABG. Gadolinium-enhanced CMR was performed using a trueFISP inversion recovery sequence on a 1.5 tesla scanner (Sonata; Siemens). Clinical data were collected prospectively. Admission costs were quantified based on standardized actual cost/day. Admission cost greater than the median was defined as 'increased'. Of 458 elective CABG cases, 45 (10%) underwent pre-operative CMR. Pre-operative characteristics [mean (S.D.) age, 64 (9) years, mortality (1%) and median (interquartile range) admission duration, 7 (6-8) days] were similar in patients who did or did not undergo CMR. In the patients undergoing CMR, eight (18%) and 11 (24%) patients had reduced LV (left ventricular) systolic function by CMR [LVEF (LV ejection fraction) <55%] and echocardiography respectively. LE (late enhancement) with gadolinium was detected in 17 (38%) patients. The average cost/day was $2723. The median (interquartile range) admission cost was $19059 ($10891-157917). CMR LVEF {OR (odds ratio), 0.93 [95% CI (confidence interval), 0.87-0.99]; P=0.03} and SV (stroke volume) index [OR 1.07 (95% CI, 1.00-1.14); P=0.02] predicted increased admission cost. CMR LVEF (P=0.08) and EuroScore tended to predict actual admission cost (P=0.09), but SV by CMR (P=0.16) and LV function by echocardiography (P=0.95) did not. In conclusion, in this exploratory investigation, pre-operative CMR findings predicted admission duration and increased admission cost in elective CABG surgery. The cost-effectiveness of CMR in risk stratification in elective CABG surgery merits prospective assessment.
Analog "neuronal" networks in early vision.
Koch, C; Marroquin, J; Yuille, A
1986-01-01
Many problems in early vision can be formulated in terms of minimizing a cost function. Examples are shape from shading, edge detection, motion analysis, structure from motion, and surface interpolation. As shown by Poggio and Koch [Poggio, T. & Koch, C. (1985) Proc. R. Soc. London, Ser. B 226, 303-323], quadratic variational problems, an important subset of early vision tasks, can be "solved" by linear, analog electrical, or chemical networks. However, in the presence of discontinuities, the cost function is nonquadratic, raising the question of designing efficient algorithms for computing the optimal solution. Recently, Hopfield and Tank [Hopfield, J. J. & Tank, D. W. (1985) Biol. Cybern. 52, 141-152] have shown that networks of nonlinear analog "neurons" can be effective in computing the solution of optimization problems. We show how these networks can be generalized to solve the nonconvex energy functionals of early vision. We illustrate this approach by implementing a specific analog network, solving the problem of reconstructing a smooth surface from sparse data while preserving its discontinuities. These results suggest a novel computational strategy for solving early vision problems in both biological and real-time artificial vision systems. PMID:3459172
Quantum dot enabled detection of Escherichia coli using a cell-phone†
Zhu, Hongying; Sikora, Uzair; Ozcan, Aydogan
2013-01-01
We report a cell-phone based Escherichia coli (E. coli) detection platform for screening of liquid samples. In this compact and cost-effective design attached to a cell-phone, we utilize anti-E. coli O157:H7 antibody functionalized glass capillaries as solid substrates to perform a quantum dot based sandwich assay for specific detection of E. coli O157:H7 in liquid samples. Using battery-powered inexpensive light-emitting-diodes (LEDs) we excite/pump these labelled E. coli particles captured on the capillary surface, where the emission from the quantum dots is then imaged using the cell-phone camera unit through an additional lens that is inserted between the capillary and the cell-phone. By quantifying the fluorescent light emission from each capillary tube, the concentration of E. coli in the sample is determined. We experimentally confirmed the detection limit of this cell-phone based fluorescent imaging and sensing platform as ~5 to 10 cfu mL−1 in buffer solution. We also tested the specificity of this E. coli detection platform by spiking samples with different species (e.g., Salmonella) to confirm that non-specific binding/detection is negligible. We further demonstrated the proof-of-concept of our approach in a complex food matrix, e.g., fat-free milk, where a similar detection limit of ~5 to 10 cfu mL−1 was achieved despite challenges associated with the density of proteins that exist in milk. Our results reveal the promising potential of this cell-phone enabled field-portable and cost-effective E. coli detection platform for e.g., screening of water and food samples even in resource limited environments. The presented platform can also be applicable to other pathogens of interest through the use of different antibodies. PMID:22396952
Quantum dot enabled detection of Escherichia coli using a cell-phone.
Zhu, Hongying; Sikora, Uzair; Ozcan, Aydogan
2012-06-07
We report a cell-phone based Escherichia coli (E. coli) detection platform for screening of liquid samples. In this compact and cost-effective design attached to a cell-phone, we utilize anti-E. coli O157:H7 antibody functionalized glass capillaries as solid substrates to perform a quantum dot based sandwich assay for specific detection of E. coli O157:H7 in liquid samples. Using battery-powered inexpensive light-emitting-diodes (LEDs) we excite/pump these labelled E. coli particles captured on the capillary surface, where the emission from the quantum dots is then imaged using the cell-phone camera unit through an additional lens that is inserted between the capillary and the cell-phone. By quantifying the fluorescent light emission from each capillary tube, the concentration of E. coli in the sample is determined. We experimentally confirmed the detection limit of this cell-phone based fluorescent imaging and sensing platform as ∼5 to 10 cfu mL(-1) in buffer solution. We also tested the specificity of this E. coli detection platform by spiking samples with different species (e.g., Salmonella) to confirm that non-specific binding/detection is negligible. We further demonstrated the proof-of-concept of our approach in a complex food matrix, e.g., fat-free milk, where a similar detection limit of ∼5 to 10 cfu mL(-1) was achieved despite challenges associated with the density of proteins that exist in milk. Our results reveal the promising potential of this cell-phone enabled field-portable and cost-effective E. coli detection platform for e.g., screening of water and food samples even in resource limited environments. The presented platform can also be applicable to other pathogens of interest through the use of different antibodies.
Wang, Xuewei; Qin, Wei
2013-07-22
The determination of peroxidase activities is the basis for enzyme-labeled bioaffinity assays, peroxidase-mimicking DNAzymes- and nanoparticles-based assays, and characterization of the catalytic functions of peroxidase mimetics. Here, a facile, sensitive, and cost-effective solvent polymeric membrane-based peroxidase detection platform is described that utilizes reaction intermediates with different pKa values from those of substrates and final products. Several key but long-debated intermediates in the peroxidative oxidation of o-phenylenediamine (o-PD) have been identified and their charge states have been estimated. By using a solvent polymeric membrane functionalized by an appropriate substituted tetraphenylborate as a receptor, those cationic intermediates could be transferred into the membrane from the aqueous phase to induce a large cationic potential response. Thus, the potentiometric indication of the o-PD oxidation catalyzed by peroxidase or its mimetics can be fulfilled. Horseradish peroxidase has been detected with a detection limit at least two orders of magnitude lower than those obtained by spectrophotometric techniques and traditional membrane-based methods. As an example of peroxidase mimetics, G-quadruplex DNAzymes were probed by the intermediate-sensitive membrane and a label-free thrombin detection protocol was developed based on the catalytic activity of the thrombin-binding G-quadruplex aptamer. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Improved minimum cost and maximum power two stage genome-wide association study designs.
Stanhope, Stephen A; Skol, Andrew D
2012-01-01
In a two stage genome-wide association study (2S-GWAS), a sample of cases and controls is allocated into two groups, and genetic markers are analyzed sequentially with respect to these groups. For such studies, experimental design considerations have primarily focused on minimizing study cost as a function of the allocation of cases and controls to stages, subject to a constraint on the power to detect an associated marker. However, most treatments of this problem implicitly restrict the set of feasible designs to only those that allocate the same proportions of cases and controls to each stage. In this paper, we demonstrate that removing this restriction can improve the cost advantages demonstrated by previous 2S-GWAS designs by up to 40%. Additionally, we consider designs that maximize study power with respect to a cost constraint, and show that recalculated power maximizing designs can recover a substantial amount of the planned study power that might otherwise be lost if study funding is reduced. We provide open source software for calculating cost minimizing or power maximizing 2S-GWAS designs.
Level set formulation of two-dimensional Lagrangian vortex detection methods
NASA Astrophysics Data System (ADS)
Hadjighasem, Alireza; Haller, George
2016-10-01
We propose here the use of the variational level set methodology to capture Lagrangian vortex boundaries in 2D unsteady velocity fields. This method reformulates earlier approaches that seek material vortex boundaries as extremum solutions of variational problems. We demonstrate the performance of this technique for two different variational formulations built upon different notions of coherence. The first formulation uses an energy functional that penalizes the deviation of a closed material line from piecewise uniform stretching [Haller and Beron-Vera, J. Fluid Mech. 731, R4 (2013)]. The second energy function is derived for a graph-based approach to vortex boundary detection [Hadjighasem et al., Phys. Rev. E 93, 063107 (2016)]. Our level-set formulation captures an a priori unknown number of vortices simultaneously at relatively low computational cost. We illustrate the approach by identifying vortices from different coherence principles in several examples.
High-speed and high-fidelity system and method for collecting network traffic
Weigle, Eric H [Los Alamos, NM
2010-08-24
A system is provided for the high-speed and high-fidelity collection of network traffic. The system can collect traffic at gigabit-per-second (Gbps) speeds, scale to terabit-per-second (Tbps) speeds, and support additional functions such as real-time network intrusion detection. The present system uses a dedicated operating system for traffic collection to maximize efficiency, scalability, and performance. A scalable infrastructure and apparatus for the present system is provided by splitting the work performed on one host onto multiple hosts. The present system simultaneously addresses the issues of scalability, performance, cost, and adaptability with respect to network monitoring, collection, and other network tasks. In addition to high-speed and high-fidelity network collection, the present system provides a flexible infrastructure to perform virtually any function at high speeds such as real-time network intrusion detection and wide-area network emulation for research purposes.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang Yan; Mohanty, Soumya D.; Center for Gravitational Wave Astronomy, Department of Physics and Astronomy, University of Texas at Brownsville, 80 Fort Brown, Brownsville, Texas 78520
2010-03-15
The detection and estimation of gravitational wave signals belonging to a parameterized family of waveforms requires, in general, the numerical maximization of a data-dependent function of the signal parameters. Because of noise in the data, the function to be maximized is often highly multimodal with numerous local maxima. Searching for the global maximum then becomes computationally expensive, which in turn can limit the scientific scope of the search. Stochastic optimization is one possible approach to reducing computational costs in such applications. We report results from a first investigation of the particle swarm optimization method in this context. The method ismore » applied to a test bed motivated by the problem of detection and estimation of a binary inspiral signal. Our results show that particle swarm optimization works well in the presence of high multimodality, making it a viable candidate method for further applications in gravitational wave data analysis.« less
A workplace breast cancer screening program. Costs and components.
Schrammel, P; Griffiths, R I; Griffiths, C B
1998-11-01
Screening for breast cancer can result in early detection of malignancies and lives saved. Many employers now offer periodic screening as an employee health benefit, and some have established screening programs in the workplace. This study was performed to identify the employer costs of breast cancer screening in the workplace, referrals for suspicious findings, and initial treatment of malignant disease. Additionally, the costs for these same services, had they been obtained outside of a workplace screening program, were estimated. Data on program components and associated costs for an established employer based breast cancer screening program were obtained. These costs were compared to those among a hypothetical cohort of women not enrolled in the workplace screening program. From 1989 through 1995, 1,416 women participated in the program. Nearly 2,500 screening mammograms and approximately 2,773 clinical breast examinations were performed, resulting in 292 referrals to physicians outside of the program for additional diagnostic procedures and treatment as needed. These referrals resulted in the detection of 12 malignancies: 8 Stage I; 3 Stage II; and 1 Stage III. Mammographic and clinical breast examination screening cost $249,041; referrals resulting in benign disease or no detectable disease cost $185,002; and referrals resulting in malignant disease, followed by initial treatment, cost $148,530. Therefore, the total cost was $582,573. Approximately 47% of the cost of referrals and initial treatment were due to employee lost productivity. Total cost in the hypothetical cohort was $1,067,948 under the assumptions that all women received screening outside of the workplace, and that the same number of malignancies were detected at the same stage as in the workplace program. These findings indicate referrals resulting in detection of benign disease or no disease accounted for a substantial proportion of the total cost of the program. In addition, employee lost productivity accounted for almost 50% of the cost of all referrals and initial treatment. Workplace screening is a relatively efficient approach for early detection of breast cancer when compared to off site screening or no screening. The efficiency could be improved with a reduction in the number and cost of unnecessary referrals.
NASA Astrophysics Data System (ADS)
Blackstock, J. M.; Covington, M. D.; Williams, S. G. W.; Myre, J. M.; Rodriguez, J.
2017-12-01
Variability in CO2 fluxes within Earth's Critical zone occurs over a wide range of timescales. Resolving this and its drivers requires high-temporal resolution monitoring of CO2 both in the soil and aquatic environments. High-cost (> 1,000 USD) gas analyzers and data loggers present cost-barriers for investigations with limited budgets, particularly if high spatial resolution is desired. To overcome high-costs, we developed an Arduino based CO2 measuring platform (i.e. gas analyzer and data logger). The platform was deployed at multiple sites within the Critical Zone overlying the Springfield Plateau aquifer in Northwest Arkansas, USA. The CO2 gas analyzer used in this study was a relatively low-cost SenseAir K30. The analyzer's optical housing was covered by a PTFE semi-permeable membrane allowing for gas exchange between the analyzer and environment. Total approximate cost of the monitoring platform was 200 USD (2% detection limit) to 300 USD (10% detection limit) depending on the K30 model used. For testing purposes, we deployed the Arduino based platform alongside a commercial monitoring platform. CO2 concentration time series were nearly identical. Notably, CO2 cycles at the surface water site, which operated from January to April 2017, displayed a systematic increase in daily CO2 amplitude. Preliminary interpretation suggests key observation of seasonally increasing stream metabolic function. Other interpretations of observed cyclical and event-based behavior are out of the scope of the study; however, the presented method describes an accurate near-hourly characterization of CO2 variability. The new platform has been shown to be operational for several months, and we infer reliable operation for much longer deployments (> 1 year) given adequate environmental protection and power supply. Considering cost-savings, this platform is an attractive option for continuous, accurate, low-power, and low-cost CO2 monitoring for remote locations, globally.
Zhang, Jian; Oueslati, Rania; Cheng, Cheng; Zhao, Ling; Chen, Jiangang; Almeida, Raul; Wu, Jayne
2018-07-30
Gram-negative bacteria are one of the most common microorganisms in the environment. Their differential detection and recognition from Gram-positive bacteria has been attracting much attention over the years. Using Escherichia coli (E. coli) as a model, we demonstrated on-site detection of Gram-negative bacteria by an AC electrokinetics-based capacitive sensing method using commercial microelectrodes functionalized with an aptamer specific to lipopolysaccharides. Dielectrophoresis effect was utilized to enrich viable bacteria to the microelectrodes rapidly, achieving a detection limit of 10 2 cells/mL within a 30 s' response time. The sensor showed a negligible response to Staphylococcus aureus (S. aureus), a Gram-positive species. The developed sensor showed significant advantages in sensitivity, selectivity, cost, operation simplicity, and response time. Therefore, this sensing method has shown great application potential for environmental monitoring, food safety, and real-time diagnosis. Copyright © 2018 Elsevier B.V. All rights reserved.
Label-free detection of DNA hybridization using carbon nanotube network field-effect transistors
NASA Astrophysics Data System (ADS)
Star, Alexander; Tu, Eugene; Niemann, Joseph; Gabriel, Jean-Christophe P.; Joiner, C. Steve; Valcke, Christian
2006-01-01
We report carbon nanotube network field-effect transistors (NTNFETs) that function as selective detectors of DNA immobilization and hybridization. NTNFETs with immobilized synthetic oligonucleotides have been shown to specifically recognize target DNA sequences, including H63D single-nucleotide polymorphism (SNP) discrimination in the HFE gene, responsible for hereditary hemochromatosis. The electronic responses of NTNFETs upon single-stranded DNA immobilization and subsequent DNA hybridization events were confirmed by using fluorescence-labeled oligonucleotides and then were further explored for label-free DNA detection at picomolar to micromolar concentrations. We have also observed a strong effect of DNA counterions on the electronic response, thus suggesting a charge-based mechanism of DNA detection using NTNFET devices. Implementation of label-free electronic detection assays using NTNFETs constitutes an important step toward low-cost, low-complexity, highly sensitive and accurate molecular diagnostics. hemochromatosis | SNP | biosensor
Mauk, Michael G.; Song, Jinzhao; Liu, Changchun; Bau, Haim H.
2018-01-01
Designs and applications of microfluidics-based devices for molecular diagnostics (Nucleic Acid Amplification Tests, NAATs) in infectious disease testing are reviewed, with emphasis on minimally instrumented, point-of-care (POC) tests for resource-limited settings. Microfluidic cartridges (‘chips’) that combine solid-phase nucleic acid extraction; isothermal enzymatic nucleic acid amplification; pre-stored, paraffin-encapsulated lyophilized reagents; and real-time or endpoint optical detection are described. These chips can be used with a companion module for separating plasma from blood through a combined sedimentation-filtration effect. Three reporter types: Fluorescence, colorimetric dyes, and bioluminescence; and a new paradigm for end-point detection based on a diffusion-reaction column are compared. Multiplexing (parallel amplification and detection of multiple targets) is demonstrated. Low-cost detection and added functionality (data analysis, control, communication) can be realized using a cellphone platform with the chip. Some related and similar-purposed approaches by others are surveyed. PMID:29495424
Guo, Zongrang; Niu, Qingfen; Li, Tianduo
2018-07-05
Developing low-cost and efficient sensors for rapid, selective and sensitive detection of the transition metal ions in environmental and food science is very important. In this study, a novel dual-functional fluorescent "turn-on" sensor 3TP based on oligothiophene-phenylamine Schiff base has been synthesized for discrimination and simultaneous detection of both Al 3+ and Fe 3+ ions with high selectivity and anti-interference over other metal ions. Sensor 3TP displayed a very fast fluorescence-enhanced response towards Al 3+ and Fe 3+ ions with low detection limits (0.177μM for Al 3+ and 0.172μM for Fe 3+ ) and wide pH response range (4.0-12.0). The Al 3+ /Fe 3+ sensing mechanisms were investigated by fluorescence experiments, 1 H NMR titrations, FT-IR and ESI-MS spectra. Importantly, sensor 3TP was served as an efficient solid material for the highly sensitive and selective detection of Fe 3+ on TLC plates. Moreover, the sensor 3TP has been successfully used to detect trace Al 3+ and Fe 3+ in environment and food samples with satisfactory results and good recoveries, revealing a convenient, reliable and accurate method for Al 3+ and Fe 3+ analysis in real samples. Copyright © 2018 Elsevier B.V. All rights reserved.
Nano-biosensor for highly sensitive detection of HER2 positive breast cancer.
Salahandish, Razieh; Ghaffarinejad, Ali; Naghib, Seyed Morteza; Majidzadeh-A, Keivan; Zargartalebi, Hossein; Sanati-Nezhad, Amir
2018-05-25
Nanocomposite materials have provided a wide range of conductivity, sensitivity, selectivity and linear response for electrochemical biosensors. However, the detection of rare cells at single cell level requires a new class of nanocomposite-coated electrodes with exceptional sensitivity and specificity. We recently developed a construct of gold nanoparticle-grafted functionalized graphene and nanostructured polyaniline (PANI) for high-performance biosensing within a very wide linear response and selective performance. Further, replacing the expensive gold nanoparticles with low-cost silver nanoparticles as well as optimizing the nanocomposite synthesis and functionalization protocols on the electrode surface in this work enabled us to develop ultrasensitive nanocomposites for label-free detection of breast cancer cells. The sensor presented a fast response time of 30 min within a dynamic range of 10 - 5 × 10 6 cells mL -1 and with a detection limit of 2 cells mL -1 for the detection of SK-BR3 breast cancer cell. The nano-biosensor, for the first time, demonstrated a high efficiency of > 90% for the label-free detection of cancer cells in whole blood sample without any need for sample preparation and cell staining. The results demonstrated that the optimized nanocomposite developed in this work is a promising nanomaterial for electrochemical biosensing and with the potential applications in electro-catalysis and super-capacitances. Copyright © 2018 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Guo, Zongrang; Niu, Qingfen; Li, Tianduo
2018-07-01
Developing low-cost and efficient sensors for rapid, selective and sensitive detection of the transition metal ions in environmental and food science is very important. In this study, a novel dual-functional fluorescent "turn-on" sensor 3TP based on oligothiophene-phenylamine Schiff base has been synthesized for discrimination and simultaneous detection of both Al3+ and Fe3+ ions with high selectivity and anti-interference over other metal ions. Sensor 3TP displayed a very fast fluorescence-enhanced response towards Al3+ and Fe3+ ions with low detection limits (0.177 μM for Al3+ and 0.172 μM for Fe3+) and wide pH response range (4.0-12.0). The Al3+/Fe3+ sensing mechanisms were investigated by fluorescence experiments, 1H NMR titrations, FT-IR and ESI-MS spectra. Importantly, sensor 3TP was served as an efficient solid material for the highly sensitive and selective detection of Fe3+ on TLC plates. Moreover, the sensor 3TP has been successfully used to detect trace Al3+ and Fe3+ in environment and food samples with satisfactory results and good recoveries, revealing a convenient, reliable and accurate method for Al3+ and Fe3+ analysis in real samples.
Jia, Kun; Bijeon, Jean Louis; Adam, Pierre Michel; Ionescu, Rodica Elena
2013-02-21
A commercial TEM grid was used as a mask for the creation of extremely well-organized gold micro-/nano-structures on a glass substrate via a high temperature annealing process at 500 °C. The structured substrate was (bio)functionalized and used for the high throughput LSPR immunosensing of different concentrations of a model protein named bovine serum albumin.
An ultrahigh-accuracy Miniature Dew Point Sensor based on an Integrated Photonics Platform.
Tao, Jifang; Luo, Yu; Wang, Li; Cai, Hong; Sun, Tao; Song, Junfeng; Liu, Hui; Gu, Yuandong
2016-07-15
The dew point is the temperature at which vapour begins to condense out of the gaseous phase. The deterministic relationship between the dew point and humidity is the basis for the industry-standard "chilled-mirror" dew point hygrometers used for highly accurate humidity measurements, which are essential for a broad range of industrial and metrological applications. However, these instruments have several limitations, such as high cost, large size and slow response. In this report, we demonstrate a compact, integrated photonic dew point sensor (DPS) that features high accuracy, a small footprint, and fast response. The fundamental component of this DPS is a partially exposed photonic micro-ring resonator, which serves two functions simultaneously: 1) sensing the condensed water droplets via evanescent fields and 2) functioning as a highly accurate, in situ temperature sensor based on the thermo-optic effect (TOE). This device virtually eliminates most of the temperature-related errors that affect conventional "chilled-mirror" hygrometers. Moreover, this DPS outperforms conventional "chilled-mirror" hygrometers with respect to size, cost and response time, paving the way for on-chip dew point detection and extension to applications for which the conventional technology is unsuitable because of size, cost, and other constraints.
An ultrahigh-accuracy Miniature Dew Point Sensor based on an Integrated Photonics Platform
NASA Astrophysics Data System (ADS)
Tao, Jifang; Luo, Yu; Wang, Li; Cai, Hong; Sun, Tao; Song, Junfeng; Liu, Hui; Gu, Yuandong
2016-07-01
The dew point is the temperature at which vapour begins to condense out of the gaseous phase. The deterministic relationship between the dew point and humidity is the basis for the industry-standard “chilled-mirror” dew point hygrometers used for highly accurate humidity measurements, which are essential for a broad range of industrial and metrological applications. However, these instruments have several limitations, such as high cost, large size and slow response. In this report, we demonstrate a compact, integrated photonic dew point sensor (DPS) that features high accuracy, a small footprint, and fast response. The fundamental component of this DPS is a partially exposed photonic micro-ring resonator, which serves two functions simultaneously: 1) sensing the condensed water droplets via evanescent fields and 2) functioning as a highly accurate, in situ temperature sensor based on the thermo-optic effect (TOE). This device virtually eliminates most of the temperature-related errors that affect conventional “chilled-mirror” hygrometers. Moreover, this DPS outperforms conventional “chilled-mirror” hygrometers with respect to size, cost and response time, paving the way for on-chip dew point detection and extension to applications for which the conventional technology is unsuitable because of size, cost, and other constraints.
Filament Advance Detection Sensor for Fused Deposition Modelling 3D Printers
Islán Marcos, Manuel
2018-01-01
The main purpose of this paper is to present a system to detect extrusion failures in fused deposition modelling (FDM) 3D printers by sensing that the filament is moving forward properly. After several years using these kind of machines, authors detected that there is not any system to detect the main problem in FDM machines. Authors thought in different sensors and used the weighted objectives method, one of the most common evaluation methods, for comparing design concepts based on an overall value per design concept. Taking into account the obtained scores of each specification, the best choice for this work is the optical encoder. Once the sensor is chosen, it is necessary to design de part where it will be installed without interfering with the normal function of the machine. To do it, photogrammetry scanning methodology was employed. The developed device perfectly detects the advance of the filament without affecting the normal operation of the machine. Also, it is achieved the primary objective of the system, avoiding loss of material, energy, and mechanical wear, keeping the premise of making a low-cost product that does not significantly increase the cost of the machine. This development has made it possible to use the printer with remains of coil filaments, which were not spent because they were not sufficient to complete an impression. Also, printing models in two colours with only one extruder has been enabled by this development. PMID:29747458
Filament Advance Detection Sensor for Fused Deposition Modelling 3D Printers.
Soriano Heras, Enrique; Blaya Haro, Fernando; de Agustín Del Burgo, José M; Islán Marcos, Manuel; D'Amato, Roberto
2018-05-09
The main purpose of this paper is to present a system to detect extrusion failures in fused deposition modelling (FDM) 3D printers by sensing that the filament is moving forward properly. After several years using these kind of machines, authors detected that there is not any system to detect the main problem in FDM machines. Authors thought in different sensors and used the weighted objectives method, one of the most common evaluation methods, for comparing design concepts based on an overall value per design concept. Taking into account the obtained scores of each specification, the best choice for this work is the optical encoder. Once the sensor is chosen, it is necessary to design de part where it will be installed without interfering with the normal function of the machine. To do it, photogrammetry scanning methodology was employed. The developed device perfectly detects the advance of the filament without affecting the normal operation of the machine. Also, it is achieved the primary objective of the system, avoiding loss of material, energy, and mechanical wear, keeping the premise of making a low-cost product that does not significantly increase the cost of the machine. This development has made it possible to use the printer with remains of coil filaments, which were not spent because they were not sufficient to complete an impression. Also, printing models in two colours with only one extruder has been enabled by this development.
Digital tripwire: a small automated human detection system
NASA Astrophysics Data System (ADS)
Fischer, Amber D.; Redd, Emmett; Younger, A. Steven
2009-05-01
A low cost, lightweight, easily deployable imaging sensor that can dependably discriminate threats from other activities within its field of view and, only then, alert the distant duty officer by transmitting a visual confirmation of the threat would provide a valuable asset to modern defense. At present, current solutions suffer from a multitude of deficiencies - size, cost, power endurance, but most notably, an inability to assess an image and conclude that it contains a threat. The human attention span cannot maintain critical surveillance over banks of displays constantly conveying such images from the field. DigitalTripwire is a small, self-contained, automated human-detection system capable of running for 1-5 days on two AA batteries. To achieve such long endurance, the DigitalTripwire system utilizes an FPGA designed with sleep functionality. The system uses robust vision algorithms, such as a partially unsupervised innovative backgroundmodeling algorithm, which employ several data reduction strategies to operate in real-time, and achieve high detection rates. When it detects human activity, either mounted or dismounted, it sends an alert including images to notify the command center. In this paper, we describe the hardware and software design of the DigitalTripwire system. In addition, we provide detection and false alarm rates across several challenging data sets demonstrating the performance of the vision algorithms in autonomously analyzing the video stream and classifying moving objects into four primary categories - dismounted human, vehicle, non-human, or unknown. Performance results across several challenging data sets are provided.
NASA Astrophysics Data System (ADS)
Medvedev, Andrei V.; Kainerstorfer, Jana M.; Borisov, Sergey V.; Vanmeter, John
2011-01-01
Near-infrared spectroscopy (NIRS) is a developing technology for low-cost noninvasive functional brain imaging. With multichannel optical instruments, it becomes possible to measure not only local changes in hemoglobin concentrations but also temporal correlations of those changes in different brain regions which gives an optical analog of functional connectivity traditionally measured by fMRI. We recorded hemodynamic activity during the Go-NoGo task from 11 right-handed subjects with probes placed bilaterally over prefrontal areas. Subjects were detecting animals as targets in natural scenes pressing a mouse button. Data were low-pass filtered <1 Hz and cardiac/respiration/superficial layers artifacts were removed using Independent Component Analysis. Fisher's transformed correlations of poststimulus responses (30 s) were averaged over groups of channels unilaterally in each hemisphere (intrahemispheric connectivity) and the corresponding channels between hemispheres (interhemispheric connectivity). The hemodynamic response showed task-related activation (an increase/decrease in oxygenated/deoxygenated hemoglobin, respectively) greater in the right versus left hemisphere. Intra- and interhemispheric functional connectivity was also significantly stronger during the task compared to baseline. Functional connectivity between the inferior and the middle frontal regions was significantly stronger in the right hemisphere. Our results demonstrate that optical methods can be used to detect transient changes in functional connectivity during rapid cognitive processes.
Van Weyenberg, Stephanie; Van Nuffel, Annelies; Lauwers, Ludwig; Vangeyte, Jürgen
2017-01-01
Simple Summary Most prototypes of systems to automatically detect lameness in dairy cattle are still not available on the market. Estimating their potential adoption rate could support developers in defining development goals towards commercially viable and well-adopted systems. We simulated the potential market shares of such prototypes to assess the effect of altering the system cost and detection performance on the potential adoption rate. We found that system cost and lameness detection performance indeed substantially influence the potential adoption rate. In order for farmers to prefer automatic detection over current visual detection, the usefulness that farmers attach to a system with specific characteristics should be higher than that of visual detection. As such, we concluded that low system costs and high detection performances are required before automatic lameness detection systems become applicable in practice. Abstract Most automatic lameness detection system prototypes have not yet been commercialized, and are hence not yet adopted in practice. Therefore, the objective of this study was to simulate the effect of detection performance (percentage missed lame cows and percentage false alarms) and system cost on the potential market share of three automatic lameness detection systems relative to visual detection: a system attached to the cow, a walkover system, and a camera system. Simulations were done using a utility model derived from survey responses obtained from dairy farmers in Flanders, Belgium. Overall, systems attached to the cow had the largest market potential, but were still not competitive with visual detection. Increasing the detection performance or lowering the system cost led to higher market shares for automatic systems at the expense of visual detection. The willingness to pay for extra performance was €2.57 per % less missed lame cows, €1.65 per % less false alerts, and €12.7 for lame leg indication, respectively. The presented results could be exploited by system designers to determine the effect of adjustments to the technology on a system’s potential adoption rate. PMID:28991188
Gold nanoparticles paper as a SERS bio-diagnostic platform.
Ngo, Ying Hui; Then, Whui Lyn; Shen, Wei; Garnier, Gil
2013-11-01
Bioactive papers are usually challenged by four major limitations: sensitivity, selectivity, simplicity and strength (4S). Gold nanoparticles (AuNPs) treated paper has previously been demonstrated as a Surface Enhanced Raman Scattering (SERS) active substrate, capable of addressing the 4S issues. In this study, AuNPs on paper substrate were functionalized by a series of biomolecules to develop a generic SERS platform for antibody-antigen detection. The functionalization steps were performed by taking advantage of the high affinity association between Streptomyces avidinii-derived protein, streptavidin, and biotin. Streptavidin was firstly bound onto the AuNPs treated paper using biotinylated-thiol. Subsequently, desired biotinylated-antibody was bound onto the streptavidin. SERS spectra of each functionalization step were obtained to ensure specific adsorption of the bio-molecules. The binding interaction of the antibody with its specific antigen was detected using SERS. Shifts of Raman band associated with α-helix and β-sheet structures indicated structural modification of the antibody upon interaction with its antigen. Predominant tryptophan and tyrosine residue bands were also detected, confirming the presence of antigen. Reproducible spectral features were quantified as AuNP papers were subjected to different concentrations of antigen; the spectra intensity increased as a function of the antigen concentration. The retention of AuNPs on paper remained constant after all the consecutive washing and functionalization steps. The feasibility of AuNPs paper as a low-cost and generic SERS platform for bio-diagnostic applications was demonstrated. Crown Copyright © 2013. Published by Elsevier Inc. All rights reserved.
Wolfger, Barbara; Manns, Braden J; Barkema, Herman W; Schwartzkopf-Genswein, Karen S; Dorin, Craig; Orsel, Karin
2015-03-01
New technologies to identify diseased feedlot cattle in early stages of illness have been developed to reduce costs and welfare impacts associated with bovine respiratory disease (BRD). However, the economic value of early BRD detection has never been assessed. The objective was to simulate cost differences between two BRD detection methods during the first 61 d on feed (DOF) applied in moderate- to large-sized feedlots using an automated recording system (ARS) for feeding behavior and the current industry standard, pen-checking (visual appraisal confirmed by rectal temperature). Economic impact was assessed with a cost analysis in a simple decision model. Scenarios for Canadian and US feedlots with high- and low-risk cattle were modeled, and uncertainty was estimated using extensive sensitivity analyses. Input costs and probabilities were mainly extracted from publicly accessible market observations and a large-scale US feedlot study. In the baseline scenario, we modeled high-risk cattle with a treatment rate of 20% within the first 61 DOF in a feedlot of >8000 cattle in Canada. Early BRD detection was estimated to result in a relative risk of 0.60 in retreatment and 0.66 in mortality compared to pen-checking (based on previously published estimates). The additional cost of monitoring health with ARS in Canadian dollar (CAD) was 13.68 per steer. Scenario analysis for similar sized US feedlots and low-risk cattle with a treatment rate of 8% were included to account for variability in costs and probabilities in various cattle populations. Considering the cost of monitoring, all relevant treatment costs and sale price, ARS was more costly than visual appraisal during the first 61 DOF by CAD 9.61 and CAD 9.69 per steer in Canada and the US, respectively. This cost difference increased in low-risk cattle in Canada to CAD 12.45. Early BRD detection with ARS became less expensive if the costs for the system decreased to less than CAD 4.06/steer, or if the underlying true BRD incidence (not treatment rate) within the first 61 DOF exceeded 47%. The model was robust to variability in the remaining input variables. Some of the assumptions in the baseline analyses were conservative and may have underestimated the real value of early BRD detection. Systems such as ARS may reduce treatment costs in some scenarios, but the investment costs are currently too high to be cost-effective when used solely for BRD detection compared to pen-checking. Copyright © 2014 Elsevier B.V. All rights reserved.
Design and testing of RFID sensor tag fabricated using inkjet-printing and electrodeposition
NASA Astrophysics Data System (ADS)
Chien Dang, Mau; Son Nguyen, Dat; Dung Dang, Thi My; Tedjini, Smail; Fribourg-Blanc, Eric
2014-06-01
The passive RFID tag with an added sensing function is of interest to many applications. In particular, applications where RFID tagging is already considered to be the next step, such as food items, are a specific target. This paper demonstrates a flexible RFID tag sensor fabricated using a low cost technique with an added zero-cost sensing function. It is more specifically applied to the sensing of degradable food, in particular beef meat in our demonstrated example. To reach this, the antenna is designed in such a way to be sensitive to the variation of the dielectric permittivity of the meat over time. The design of the sensing tag as well as its fabrication process are described. The fabrication involves inkjet printing of a silver nanoparticle based ink on a commercial low cost PET film to create a seed layer. It is followed by a copper electrodeposition step on top of the silver pattern to complete the tag to obtain the desired thickness and conductivity of the tag antenna. The results of the electrical tests showed that with the inkjet printing-electrodeposition combination it is possible to produce flexible electrically conductive patterns for practical RFID applications. The tag was then tested in close-to-real-world conditions and it is demonstrated that it can provide a sensing function to detect the consumption limit of the packaged beef.
Investigation of magnetic microdiscs for bacterial pathogen detection
NASA Astrophysics Data System (ADS)
Castillo-Torres, Keisha Y.; Garraud, Nicolas; Arnold, David P.; McLamore, Eric S.
2016-05-01
Despite strict regulations to control the presence of human pathogens in our food supply, recent foodborne outbreaks have heightened public concern about food safety and created urgency to improve methods for pathogen detection. Herein we explore a potentially portable, low-cost system that uses magnetic microdiscs for the detection of bacterial pathogens in liquid samples. The system operates by optically measuring the rotational dynamics of suspended magnetic microdiscs functionalized with pathogen-binding aptamers. The soft ferromagnetic (Ni80Fe20) microdiscs exhibit a closed magnetic spin arrangement (i.e. spin vortex) with zero magnetic stray field, leading to no disc agglomeration when in free suspension. With very high surface area for functionalization and volumes 10,000x larger than commonly used superparamagnetic nanoparticles, these 1.5-μm-diameter microdiscs are well suited for tagging, trapping, actuating, or interrogating bacterial targets. This work reports a wafer-level microfabrication process for fabrication of 600 million magnetic microdiscs per substrate and measurement of their rotational dynamics response. Additionally, the biofunctionalization of the microdiscs with DNA aptamers, subsequent binding to E. coli bacteria, and their magnetic manipulation is reported.
Molloy, Erin K; Meyerand, Mary E; Birn, Rasmus M
2014-02-01
Functional MRI blood oxygen level-dependent (BOLD) signal changes can be subtle, motivating the use of imaging parameters and processing strategies that maximize the temporal signal-to-noise ratio (tSNR) and thus the detection power of neuronal activity-induced fluctuations. Previous studies have shown that acquiring data at higher spatial resolutions results in greater percent BOLD signal changes, and furthermore that spatially smoothing higher resolution fMRI data improves tSNR beyond that of data originally acquired at a lower resolution. However, higher resolution images come at the cost of increased acquisition time, and the number of image volumes also influences detectability. The goal of our study is to determine how the detection power of neuronally induced BOLD fluctuations acquired at higher spatial resolutions and then spatially smoothed compares to data acquired at the lower resolutions with the same imaging duration. The number of time points acquired during a given amount of imaging time is a practical consideration given the limited ability of certain populations to lie still in the MRI scanner. We compare acquisitions at three different in-plane spatial resolutions (3.50×3.50mm(2), 2.33×2.33mm(2), 1.75×1.75mm(2)) in terms of their tSNR, contrast-to-noise ratio, and the power to detect both task-related activation and resting-state functional connectivity. The impact of SENSE acceleration, which speeds up acquisition time increasing the number of images collected, is also evaluated. Our results show that after spatially smoothing the data to the same intrinsic resolution, lower resolution acquisitions have a slightly higher detection power of task-activation in some, but not all, brain areas. There were no significant differences in functional connectivity as a function of resolution after smoothing. Similarly, the reduced tSNR of fMRI data acquired with a SENSE factor of 2 is offset by the greater number of images acquired, resulting in few significant differences in detection power of either functional activation or connectivity after spatial smoothing. © 2013.
Magnetic wire trap arrays for biomarker-based molecular detection
NASA Astrophysics Data System (ADS)
Vieira, Gregory; Mahajan, Kalpesh; Ruan, Gang; Winter, Jessica; Sooryakumar, R.
2012-02-01
Submicrometer-scale magnetic devices built on chip-based platforms have recently been shown to present opportunities for new particle trapping and manipulation technologies. Meanwhile, advances in nanoparticle fabrication allow for the building of custom-made particles with precise control of their size, composition, and other properties such as magnetism, fluorescence, and surface biomarker characteristics. In particular, carefully tailored surface biomarkers facilitate precise binding to targeted molecules, self-actuated construction of hybrid structures, and fluorescence-based detection schemes. Based on these progresses, we present an on-chip detection mechanism for molecules with known surface markers. Hybrid nanostructures consisting of micelle nanoparticles, fluorescent quantum dots, and superparamagnetic iron oxide nanoparticles are used to detect proteins or DNA molecules. The target is detected by the magnetic and fluorescent functionalities of the composite nanostructure, whereas in the absence of the target these signals are not present. Underlying this approach is the simultaneous manipulation via ferromagnetic zigzag nanowire arrays and imaging via quantum dot excitation. This chip-based detection technique could provide a powerful, low cost tool for ultrasensitive molecule detection with ramifications in healthcare diagnostics and small-scale chemical synthesis.
Gordon, Louisa G; Rowell, David
2015-03-01
The objective of this study was to review the literature for malignant melanoma, basal and squamous cell carcinomas to understand: (a) national estimates of the direct health system costs of skin cancer and (b) the cost-effectiveness of interventions for skin cancer prevention or early detection. A systematic review was performed using Medline, Cochrane Library and the National Health Service Economic Evaluation Databases as well as a manual search of reference lists to identify relevant studies up to 31 August 2013. A narrative synthesis approach was used to summarize the data. National cost estimates were adjusted for country-specific inflation and presented in 2013 euros. The CHEERS statement was used to assess the quality of the economic evaluation studies. Sixteen studies reporting national estimates of skin cancer costs and 11 cost-effectiveness studies on skin cancer prevention or early detection were identified. Relative to the size of their respective populations, the annual direct health system costs for skin cancer were highest for Australia, New Zealand, Sweden and Denmark (2013 euros). Skin cancer prevention initiatives are highly cost-effective and may also be cost-saving. Melanoma early detection programmes aimed at high-risk individuals may also be cost-effective; however, updated analyses are needed. There is a significant cost burden of skin cancer for many countries and health expenditure for this disease will grow as incidence increases. Public investment in skin cancer prevention and early detection programmes show strong potential for health and economic benefits.
NASA Astrophysics Data System (ADS)
Krimmer, J.; Angellier, G.; Balleyguier, L.; Dauvergne, D.; Freud, N.; Hérault, J.; Létang, J. M.; Mathez, H.; Pinto, M.; Testa, E.; Zoccarato, Y.
2017-04-01
For the purpose of detecting deviations from the prescribed treatment during particle therapy, the integrals of uncollimated prompt gamma-ray timing distributions are investigated. The intention is to provide information, with a simple and cost-effective setup, independent from monitoring devices of the beamline. Measurements have been performed with 65 MeV protons at a clinical cyclotron. Prompt gamma-rays emitted from the target are identified by means of time-of-flight. The proton range inside the PMMA target has been varied via a modulator wheel. The measured variation of the prompt gamma peak integrals as a function of the modulator position is consistent with simulations. With detectors covering a solid angle of 25 msr (corresponding to a diameter of 3-4 in. at a distance of 50 cm from the beam axis) and 108 incident protons, deviations of a few per cent in the prompt gamma-ray count rate can be detected. For the present configuration, this change in the count rate corresponds to a 3 mm change in the proton range in a PMMA target. Furthermore, simulation studies show that a combination of the signals from multiple detectors may be used to detect a misplacement of the target. A different combination of these signals results in a precise number of the detected prompt gamma rays, which is independent on the actual target position.
NASA Astrophysics Data System (ADS)
Liu, Haijian; Li, Ming; Jiang, Linye; Shen, Feng; Hu, Yufeng; Ren, Xueqin
2017-02-01
Arginine plays an important role in many biological functions, whose detection is very significant. Herein, a sensitive, simple and cost-effective fluorescent method for the detection of arginine has been developed based on the inner filter effect (IFE) of citrate-stabilized gold nanoparticles (AuNPs) on the fluorescence of thioglycolic acid-capped CdTe quantum dots (QDs). When citrate-stabilized AuNPs were mixed with thioglycolic acid-capped CdTe QDs, the fluorescence of CdTe QDs was significantly quenched by AuNPs via the IFE. With the presence of arginine, arginine could induce the aggregation and corresponding absorption spectra change of AuNPs, which then IFE-decreased fluorescence could gradually recover with increasing amounts of arginine, achieving fluorescence ;turn on; sensing for arginine. The detection mechanism is clearly illustrated and various experimental conditions were also optimized. Under the optimum conditions, a decent linear relationship was obtained in the range from 16 to 121 μg L- 1 and the limit of detection was 5.6 μg L- 1. And satisfactory results were achieved in arginine analysis using arginine injection, compound amino acid injection, even blood plasma as samples. Therefore, the present assay showed various merits, such as simplicity, low cost, high sensitivity and selectivity, making it promising for sensing arginine in biological samples.
Development of a rapid low cost fluorescent biosensor for the detection of food contaminants.
McGrath, Terry F; Andersson, Karl; Campbell, Katrina; Fodey, Terry L; Elliott, Christopher T
2013-03-15
A prototype fluorescent based biosensor has been developed for the antibody based detection of food related contaminants. Its performance was characterised and showed a typical antibody binding signal of 200-2000 mV, a short term noise of 9.1 mV, and baseline slope of -0.016 mV/s over 4h. Bulk signal detection repeatability (n=23) and reproducibility (n=3) were less than 2.4%CV. The biosensor detection unit was evaluated using two food related model systems proving its ability to monitor both binding using commercial products and inhibition through the development of an assay. This assay development potential was evaluated by observing the biosensor's performance whilst appraising several labelled antibody and glass slide configurations. The molecular interaction between biotin and an anti-biotin antibody was shown to be inhibited by 41% due to the presence of biotin in a sample. A food toxin (domoic acid) calibration curve was produced, with %CVs ranging from 2.7 to 7.8%, and a midpoint of approximately 17 ng/ml with further optimisation possible. The ultimate aim of this study was to demonstrate the working principles of this innovative biosensor as a potential portable tool with the opportunity of interchangeable assays. The biosensor design is applicable for the requirements of routine food contaminant analysis, with respect to performance, functionality and cost. Copyright © 2012 Elsevier B.V. All rights reserved.
Tian, Jingqi; Liu, Qian; Shi, Jinle; Hu, Jianming; Asiri, Abdullah M; Sun, Xuping; He, Yuquan
2015-09-15
Considerable recent attention has been paid to homogeneous fluorescent DNA detection with the use of nanostructures as a universal "quencher", but it still remains a great challenge to develop such nanosensor with the benefits of low cost, high speed, sensitivity, and selectivity. In this work, we report the use of iron-based metal-organic framework nanorods as a high-efficient sensing platform for fluorescent DNA detection. It only takes about 4 min to complete the whole "mix-and-detect" process with a low detection limit of 10 pM and a strong discrimination of single point mutation. Control experiments reveal the remarkable sensing behavior is a consequence of the synergies of the metal center and organic linker. This work elucidates how composition control of nanostructures can significantly impact their sensing properties, enabling new opportunities for the rational design of functional materials for analytical applications. Copyright © 2015 Elsevier B.V. All rights reserved.
GMR microfluidic biosensor for low concentration detection of Nanomag-D beads
NASA Astrophysics Data System (ADS)
Devkota, J.; Kokkinis, G.; Jamalieh, M.; Phan, M. H.; Srikanth, H.; Cardoso, S.; Cardoso, F. A.; Giouroudi, I.
2015-06-01
This paper presents a novel microfluidic biosensor for in-vitro detection of biomolecules labeled by magnetic biomarkers (Nanomag-D beads) suspended in a static fluid in combination with giant magnetoresistance (GMR) sensors. While previous studies were focused mainly on exploring the MR change for biosensing of bacteria labeled with magnetic microparticles, we show that our biosensor can be used for the detection of much smaller pathogens in the range of a few hundred nanometers e.g., viruses labeled with Nanomag-D beads (MNPs). For the measurements we also used a novel method for signal acquisition and demodulation. Expensive function generators, data acquisition devices and lock-in amplifiers are substituted by a generic PC sound card and an algorithm combining the Fast Fourier Transform (FFT) of the signal with a peak detection routine. This way, costs are drastically reduced, portability is enabled, detection hands-on time is reduced, and sample throughput can be increased using automation and efficient data evaluation with the appropriate software.
Dong, Tao; Pires, Nuno Miguel Matos
2017-08-15
This work reports a novel optical microfluidic biosensor with highly sensitive organic photodetectors (OPDs) for absorbance-based detection of salivary protein biomarkers at the point of care. The compact and miniaturized biosensor has comprised OPDs made of polythiophene-C 70 bulk heterojunction for the photoactive layer; whilst a calcium-free cathode interfacial layer, made of linear polyethylenimine, was incorporated to the photodetectors to enhance the low cost. The OPDs realized onto a glass chip were aligned to antibody-functionalized chambers of a poly(methyl methacrylate) microfluidic chip, in where immunogold-silver assays were conducted. The biosensor has detected IL-8, IL-1β and MMP-8 protein in spiked saliva with high detection specificity and short analysis time exhibiting detection limits between 80pgmL -1 and 120pgmL -1 . The result for IL-8 was below the clinical established cut-off of 600pgmL -1 , which revealed the potential of the biosensor to early detection of oral cancer. The detection limit was also comparable to other previously reported immunosensors performed with bulky instrumentation or using inorganic photodetectors. The optical detection sensitivity of the polythiophene-C 70 OPD was enhanced by optimizing the thickness of the photoactive layer and anode interfacial layer prior to the saliva immunoassays. Further, the biosensor was tested with unspiked human saliva samples, and the results of measuring IL-8 and IL-1β were in statistical agreement with those provided by two commercial assays of ELISA. The optical microfluidic biosensor reported hereby offers an attractive and cost-effective tool to diagnostics or screening purposes at the point of care. Copyright © 2017 Elsevier B.V. All rights reserved.
Investment in online self-evaluation tests: A theoretical approach.
de Gara, Francesco; Gallo, William T; Bisson, Jonathan I; Endrass, Jerome; Vetter, Stefan
2008-04-15
Large-scale traumatic events may burden any affected public health system with consequential charges. One major post-disaster, expense factor emerges form early psychological interventions and subsequent, posttraumatic mental health care. Due to the constant increase in mental health care costs, also post-disaster public mental health requires best possible, cost-effective care systems. Screening and monitoring the affected population might be one such area to optimize the charges. This paper analyzes the potential cost-effectiveness of monitoring a psychologically traumatized population and to motivate individuals at risk to seek early treatment. As basis for our model served Grossman's health production function, which was modified according to fundamental concepts of cost-benefit analyzes, to match the basic conditions of online monitoring strategies. We then introduce some fundamental concepts of cost-benefit analysis. When performing cost-benefit analyses, policy makers have to consider both direct costs (caused by treatment) and indirect costs (due to non-productivity). Considering both costs sources we find that the use of Internet-based psychometric screening instruments may reduce the duration of future treatment, psychological burden and treatment costs. The identification of individuals at risk for PTSD following a disaster may help organizations prevent both the human and the economic costs of this disease. Consequently future research on mental health issues should put more emphasis on the importance of monitoring to detect early PTSD and focus the most effective resources within early treatment and morbidity prevention.
Cost function approach for estimating derived demand for composite wood products
T. C. Marcin
1991-01-01
A cost function approach was examined for using the concept of duality between production and input factor demands. A translog cost function was used to represent residential construction costs and derived conditional factor demand equations. Alternative models were derived from the translog cost function by imposing parameter restrictions.
Qiu, Xianbo; Song, Liuwei; Yang, Shuo; Guo, Meng; Yuan, Quan; Ge, Shengxiang; Min, Xiaoping; Xia, Ningshao
2016-01-01
A fast and low-cost method for HBV genotyping especially for genotypes A, B, C and D was developed and tested. A classifier was used to detect and analyze a one-step immunoassay lateral flow strip functionalized with genotype-specific monoclonal antibodies (mAbs) on multiple capture lines in the form of pattern recognition for point-of-care (POC) diagnostics. The fluorescent signals from the capture lines and the background of the strip were collected via multiple optical channels in parallel. A digital HBV genotyping model, whose inputs are the fluorescent signals and outputs are a group of genotype-specific digital binary codes (0/1), was developed based on the HBV genotyping strategy. Meanwhile, a companion decoding table was established to cover all possible pairing cases between the states of a group of genotype-specific digital binary codes and the HBV genotyping results. A logical analyzing module was constructed to process the detected signals in parallel without program control, and its outputs were used to drive a set of LED indicators, which determine the HBV genotype. Comparing to the nucleic acid analysis to HBV viruses, much faster HBV genotyping with significantly lower cost can be obtained with the developed method. PMID:27306485
Zilinskas, Julius; Lančinskas, Algirdas; Guarracino, Mario Rosario
2014-01-01
In this paper we propose some mathematical models to plan a Next Generation Sequencing experiment to detect rare mutations in pools of patients. A mathematical optimization problem is formulated for optimal pooling, with respect to minimization of the experiment cost. Then, two different strategies to replicate patients in pools are proposed, which have the advantage to decrease the overall costs. Finally, a multi-objective optimization formulation is proposed, where the trade-off between the probability to detect a mutation and overall costs is taken into account. The proposed solutions are devised in pursuance of the following advantages: (i) the solution guarantees mutations are detectable in the experimental setting, and (ii) the cost of the NGS experiment and its biological validation using Sanger sequencing is minimized. Simulations show replicating pools can decrease overall experimental cost, thus making pooling an interesting option.
Ma, Wen; Situ, Bo; Lv, Weifeng; Li, Bo; Yin, Xiaomao; Vadgama, Pankaj; Zheng, Lei; Wang, Wen
2016-06-15
MicroRNAs (miRNAs) show great potential for disease diagnostics due to their specific molecular profiles. Detection of miRNAs remains challenging and often requires sophisticated platforms. Here we report a multienzyme-functionalized magnetic microcarriers-assisted isothermal strand-displacement polymerase reaction (ISDPR) for quantitative detection of miRNAs. Magnetic micro-carriers (MMCs) were functionalized with molecular beacons to enable miRNAs recognition and magnetic separation. The target miRNAs triggered a phi29-mediated ISDPR, which can produce biotin-modified sequences on the MMCs. Streptavidin-alkaline phosphatase was then conjugated to the MMC surface through biotin-streptavidin interactions. In the presence of 2-phospho-L-ascorbic acid, miRNAs were quantitatively determined on a screen-printed carbon electrode from the anodic current of the enzymatic product. We show that this method enables detection of miRNAs as low as 9 fM and allows the discrimination of one base mismatched sequence. The proposed method was also successfully applied to analyze miRNAs in clinical tumor samples. This paper reports a new strategy for miRNAs analysis with high sensitivity, simplicity, and low cost. It would be particularly useful for rapid point-of-care testing of miRNAs in clinical laboratory. Copyright © 2015 Elsevier B.V. All rights reserved.
Surveillance for vancomycin-resistant enterococci: type, rates, costs, and implications.
Shadel, Brooke N; Puzniak, Laura A; Gillespie, Kathleen N; Lawrence, Steven J; Kollef, Marin; Mundy, Linda M
2006-10-01
To evaluate 2 active surveillance strategies for detection of enteric vancomycin-resistant enterococci (VRE) in an intensive care unit (ICU). Thirty-month prospective observational study. ICU at a university-affiliated referral center. All patients with an ICU stay of 24 hours or more were eligible for the study. Clinical active surveillance (CAS), involving culture of a rectal swab specimen for detection of VRE, was performed on admission, weekly while the patient was in the ICU, and at discharge. Laboratory-based active surveillance (LAS), involving culture of a stool specimen for detection of VRE, was performed on stool samples submitted for Clostridium difficile toxin detection. Enteric colonization with VRE was detected in 309 (17%) of 1,872 patients. The CAS method initially detected 280 (91%) of the 309 patients colonized with VRE, compared with 25 patients (8%) detected by LAS; colonization in 4 patients (1%) was initially detected by analysis of other clinical specimens. Most patients with colonization (76%) would have gone undetected by LAS alone, whereas use of the CAS method exclusively would have missed only 3 patients (1%) who were colonized. CAS cost Dollars 1,913 per month, or Dollars 57,395 for the 30-month study period. Cost savings of CAS from preventing cases of VRE colonization and bacteremia were estimated to range from Dollars 56,258 to Dollars 303,334 per month. A patient-based CAS strategy for detection of enteric colonization with VRE was superior to LAS. In this high-risk setting, CAS appeared to be the most efficient and cost-effective surveillance method. The modest costs of CAS were offset by the averted costs associated with the prevention of VRE colonization and bacteremia.
NASA Astrophysics Data System (ADS)
Zamora, G.; Chekh, V.; Burge, M.; Barriga, E. S.; Luan, S.; Heintz, P.; Edwards, A.; McGrew, E.; Soliz, P.
2012-03-01
The purpose of this research is to quantify functional signals in the microvascular circulation of the plantar. Our device is based on thermal and spectral technologies that can be easily adopted in clinical and tele-screening settings. Eightytwo thousand amputations are performed annually on diabetics in the US. The cost of foot disorder diagnosis and management are estimated at $10.9 billion dollars annually. Our experiments on normal controls and diabetics assess the temperature recovery time characteristics due to cold provocation to the bottom of the foot (plantar). A difference in the nature of the recovery time between normal controls and diabetics was observed.
ERIC Educational Resources Information Center
Chen, Huai-Yi; Nieh, Hwa-Ming; Yang, Ming-Feng; Chou, Yu-Kung; Chung, Jui-Hsu; Liou, Je-Wen
2016-01-01
This study proposes a home-assembled, low-cost blue light-emitting diode (LED) photometer that uses simple and low-cost hardware and software, costing about US $150. This 425-nm wavelength photometer is controlled by an 89C51 microcontroller chip. Glucose concentration detection experiments involving enzyme coupling reactions were carried out to…
Low-cost functional plasticity of TRPV1 supports heat tolerance in squirrels and camels.
Laursen, Willem J; Schneider, Eve R; Merriman, Dana K; Bagriantsev, Sviatoslav N; Gracheva, Elena O
2016-10-04
The ability to sense heat is crucial for survival. Increased heat tolerance may prove beneficial by conferring the ability to inhabit otherwise prohibitive ecological niches. This phenomenon is widespread and is found in both large and small animals. For example, ground squirrels and camels can tolerate temperatures more than 40 °C better than many other mammalian species, yet a molecular mechanism subserving this ability is unclear. Transient receptor potential vanilloid 1 (TRPV1) is a polymodal ion channel involved in the detection of noxious thermal and chemical stimuli by primary afferents of the somatosensory system. Here, we show that thirteen-lined ground squirrels (Ictidomys tridecemlineatus) and Bactrian camels (Camelus ferus) express TRPV1 orthologs with dramatically reduced temperature sensitivity. The loss of sensitivity is restricted to temperature and does not affect capsaicin or acid responses, thereby maintaining a role for TRPV1 as a detector of noxious chemical cues. We show that heat sensitivity can be reengineered in both TRPV1 orthologs by a single amino acid substitution in the N-terminal ankyrin-repeat domain. Conversely, reciprocal mutations suppress heat sensitivity of rat TRPV1, supporting functional conservation of the residues. Our studies suggest that squirrels and camels co-opt a common molecular strategy to adapt to hot environments by suppressing the efficiency of TRPV1-mediated heat detection at the level of somatosensory neurons. Such adaptation is possible because of the remarkable functional flexibility of the TRPV1 molecule, which can undergo profound tuning at the minimal cost of a single amino acid change.
Low-cost functional plasticity of TRPV1 supports heat tolerance in squirrels and camels
Laursen, Willem J.; Merriman, Dana K.; Bagriantsev, Sviatoslav N.; Gracheva, Elena O.
2016-01-01
The ability to sense heat is crucial for survival. Increased heat tolerance may prove beneficial by conferring the ability to inhabit otherwise prohibitive ecological niches. This phenomenon is widespread and is found in both large and small animals. For example, ground squirrels and camels can tolerate temperatures more than 40 °C better than many other mammalian species, yet a molecular mechanism subserving this ability is unclear. Transient receptor potential vanilloid 1 (TRPV1) is a polymodal ion channel involved in the detection of noxious thermal and chemical stimuli by primary afferents of the somatosensory system. Here, we show that thirteen-lined ground squirrels (Ictidomys tridecemlineatus) and Bactrian camels (Camelus ferus) express TRPV1 orthologs with dramatically reduced temperature sensitivity. The loss of sensitivity is restricted to temperature and does not affect capsaicin or acid responses, thereby maintaining a role for TRPV1 as a detector of noxious chemical cues. We show that heat sensitivity can be reengineered in both TRPV1 orthologs by a single amino acid substitution in the N-terminal ankyrin-repeat domain. Conversely, reciprocal mutations suppress heat sensitivity of rat TRPV1, supporting functional conservation of the residues. Our studies suggest that squirrels and camels co-opt a common molecular strategy to adapt to hot environments by suppressing the efficiency of TRPV1-mediated heat detection at the level of somatosensory neurons. Such adaptation is possible because of the remarkable functional flexibility of the TRPV1 molecule, which can undergo profound tuning at the minimal cost of a single amino acid change. PMID:27638213
Weetman, David; Mitchell, Sara N; Wilding, Craig S; Birks, Daniel P; Yawson, Alexander E; Essandoh, John; Mawejje, Henry D; Djogbenou, Luc S; Steen, Keith; Rippon, Emily J; Clarkson, Christopher S; Field, Stuart G; Rigden, Daniel J; Donnelly, Martin J
2015-01-01
Functionally constrained genes are ideal insecticide targets because disruption is often fatal, and resistance mutations are typically costly. Synaptic acetylcholinesterase (AChE) is an essential neurotransmission enzyme targeted by insecticides used increasingly in malaria control. In Anopheles and Culex mosquitoes, a glycine–serine substitution at codon 119 of the Ace-1 gene confers both resistance and fitness costs, especially for 119S/S homozygotes. G119S in Anopheles gambiae from Accra (Ghana) is strongly associated with resistance, and, despite expectations of cost, resistant 119S alleles are increasing significantly in frequency. Sequencing of Accra females detected only a single Ace-1 119S haplotype, whereas 119G diversity was high overall but very low at non-synonymous sites, evidence of strong purifying selection driven by functional constraint. Flanking microsatellites showed reduced diversity, elevated linkage disequilibrium and high differentiation of 119S, relative to 119G homozygotes across up to two megabases of the genome. Yet these signals of selection were inconsistent and sometimes weak tens of kilobases from Ace-1. This unexpected finding is attributable to apparently ubiquitous amplification of 119S alleles as part of a large copy number variant (CNV) far exceeding the size of the Ace-1 gene, whereas 119G alleles were unduplicated. Ace-1 CNV was detectable in archived samples collected when the 119S allele was rare in Ghana. Multicopy amplification of resistant alleles has not been observed previously and is likely to underpin the recent increase in 119S frequency. The large CNV compromised localization of the strong selective sweep around Ace-1, emphasizing the need to integrate CNV analysis into genome scans for selection. PMID:25865270
Microphotonic devices for compact planar lightwave circuits and sensor systems
NASA Astrophysics Data System (ADS)
Cardenas Gonzalez, Jaime
2005-07-01
Higher levels of integration in planar lightwave circuits and sensor systems can reduce fabrication costs and broaden viable applications for optical network and sensor systems. For example, increased integration and functionality can lead to sensor systems that are compact enough for easy transport, rugged enough for field applications, and sensitive enough even for laboratory applications. On the other hand, more functional and compact planar lightwave circuits can make optical networks components less expensive for the metro and access markets in urban areas and allow penetration of fiber to the home. Thus, there is an important area of opportunity for increased integration to provide low cost, compact solutions in both network components and sensor systems. In this dissertation, a novel splitting structure for microcantilever deflection detection is introduced. The splitting structure is designed so that its splitting ratio is dependent on the vertical position of the microcantilever. With this structure, microcantilevers sensitized to detect different analytes or biological agents can be integrated into an array on a single chip. Additionally, the integration of a depolarizer into the optoelectronic integrated circuit in an interferometric fiber optic gyroscope is presented as a means for cost reduction. The savings come in avoiding labor intensive fiber pigtailing steps by permitting batch fabrication of these components. In particular, this dissertation focuses on the design of the waveguides and polarization rotator, and the impact of imperfect components on the performance of the depolarizer. In the area of planar lightwave circuits, this dissertation presents the development of a fabrication process for single air interface bends (SAIBs). SAIBs can increase integration by reducing the area necessary to make a waveguide bend. Fabrication and measurement of a 45° SAIB with a bend efficiency of 93.4% for TM polarization and 92.7% for TE polarization are presented.
Shi, Yupeng; Pan, Yi; Zhang, Heng; Zhang, Zhaomin; Li, Mei-Jin; Yi, Changqing; Yang, Mengsu
2014-06-15
Glutathione (GSH) plays key roles in biological systems and serves many cellular functions. Since biothiols all incorporate thiol, carboxylic and amino groups, discriminative detection of GSH over cysteine (Cys) and homocysteine (Hcy) is still challenging. We herein report a dual-mode nanosensor with both colorimetric and fluorometric readout based on carbon quantum dots and gold nanoparticles for discriminative detection of GSH over Cys/Hcy. The proposed sensing system consists of AuNPs and fluorescent carbon quantum dots (CQDs), where CQDs function as fluorometric reporter, and AuNPs serve a dual function as colorimetric reporter and fluorescence quencher. The mechanism of the nanosensor is based on two distance-dependent phenomenons, color change of AuNPs and FRET. Through controlling the surface properties of as-prepared nanoparticles, the addition of CQDs into AuNPs colloid solution might induce the aggregation of AuNPs and CQDs, leading to AuNPs color changing from red to blue and CQDs fluorescence quench. However, the presence of GSH can protect AuNPs from being aggregated and enlarge the inter-particle distance, which subsequently produces color change and fluorescent signal recovery. The nanosensor described in this report reflects on its simplicity and flexibility, where no further surface functionalization is required for the as-prepared nanoparticles, leading to less laborious and more cost-effective synthesis. The proposed dual-mode nanosensor demonstrated highly selectivity toward GSH, and allows the detection of GSH as low as 50 nM. More importantly, the nanosensor could not only function in aqueous solution for GSH detection with high sensitivity but also exhibit sensitive responses toward GSH in complicated biological environments, demonstrating its potential in bioanalysis and biodection, which might be significant in disease diagnosis in the future. Copyright © 2014 Elsevier B.V. All rights reserved.
Cost-effective fence line and process monitoring systems to support advanced leak detection and repair (LDAR) strategies can enhance protection of public health, facilitate worker safety, and help companies realize cost savings by reducing lost product. The U.S. EPA Office of Re...
Low cost charged-coupled device (CCD) based detectors for Shiga toxins activity analysis
USDA-ARS?s Scientific Manuscript database
To improve food safety there is a need to develop simple, low-cost sensitive devices for detection of foodborne pathogens and their toxins. We describe a simple and relatively low-cost webcam-based detector which can be used for various optical detection modalities, including fluorescence, chemilumi...
Welby, S; van Schaik, G; Veldhuis, A; Brouwer-Middelesch, H; Peroz, C; Santman-Berends, I M; Fourichon, C; Wever, P; Van der Stede, Y
2017-12-01
Quick detection and recovery of country's freedom status remain a constant challenge in animal health surveillance. The efficacy and cost efficiency of different surveillance components in proving the absence of infection or (early) detection of bluetongue serotype 8 in cattle populations within different countries (the Netherlands, France, Belgium) using surveillance data from years 2006 and 2007 were investigated using an adapted scenario tree model approach. First, surveillance components (sentinel, yearly cross-sectional and passive clinical reporting) within each country were evaluated in terms of efficacy for substantiating freedom of infection. Yearly cross-sectional survey and passive clinical reporting performed well within each country with sensitivity of detection values ranging around 0.99. The sentinel component had a sensitivity of detection around 0.7. Secondly, how effective the components were for (early) detection of bluetongue serotype 8 and whether syndromic surveillance on reproductive performance, milk production and mortality data available from the Netherlands and Belgium could be of added value were evaluated. Epidemic curves were used to estimate the timeliness of detection. Sensitivity analysis revealed that expected within-herd prevalence and number of herds processed were the most influential parameters for proving freedom and early detection. Looking at the assumed direct costs, although total costs were low for sentinel and passive clinical surveillance components, passive clinical surveillance together with syndromic surveillance (based on reproductive performance data) turned out most cost-efficient for the detection of bluetongue serotype 8. To conclude, for emerging or re-emerging vectorborne disease that behaves such as bluetongue serotype 8, it is recommended to use passive clinical and syndromic surveillance as early detection systems for maximum cost efficiency and sensitivity. Once an infection is detected and eradicated, cross-sectional screening for substantiating freedom of infection and sentinel for monitoring the disease evolution are recommended. © 2016 Blackwell Verlag GmbH.
NASA Astrophysics Data System (ADS)
Demos, Stavros G.; Urayama, Shiro
2014-03-01
Despite best efforts, bile duct injury during laparoscopic cholecystectomy is a major potential complication. Precise detection method of extrahepatic bile duct during laparoscopic procedures would minimize the risk of injury. Towards this goal, we have developed a compact imaging instrumentation designed to enable simultaneous acquisition of conventional white color and NIR fluorescence endoscopic/laparoscopic imaging using ICG as contrast agent. The capabilities of this system, which offers optimized sensitivity and functionality, are demonstrated for the detection of the bile duct in an animal model. This design could also provide a low-cost real-time surgical navigation capability to enhance the efficacy of a variety of other image-guided minimally invasive procedures.
On a cost functional for H2/H(infinity) minimization
NASA Technical Reports Server (NTRS)
Macmartin, Douglas G.; Hall, Steven R.; Mustafa, Denis
1990-01-01
A cost functional is proposed and investigated which is motivated by minimizing the energy in a structure using only collocated feedback. Defined for an H(infinity)-norm bounded system, this cost functional also overbounds the H2 cost. Some properties of this cost functional are given, and preliminary results on the procedure for minimizing it are presented. The frequency domain cost functional is shown to have a time domain representation in terms of a Stackelberg non-zero sum differential game.
The Role of Self-Esteem and Self-Efficacy in Detecting Responses to Feedback
1998-07-01
self -efficacy on a novel task may be a function of self - esteem and initial instruction on the task. It may be that low SEs initial self ...than will persons low in self -efficacy. This may also have implications for the interaction between self -efficacy and self - esteem . In situations...feedback than persons with low SE. Persons with low self - esteem are likely to perceive 32 greater feedback seeking costs (as noted earlier).
Complexity and performance of on-chip biochemical assays
NASA Astrophysics Data System (ADS)
Kopf-Sill, Anne R.; Nikiforov, Theo; Bousse, Luc J.; Nagle, Rob; Parce, J. W.
1997-03-01
The use of microchips for performing biochemical processes has the potential to reduce reagent use and thus assay costs, increase throughput, and automate complex processes. We are building a multifunctional platform that provides sensing and actuation functions for a variety of microchip- based biochemical and analytical processes. Here we describe recent experiments that include on-chip dilution, reagent mixing, reaction, separation, and detection for important classes of biochemical assays. Issues in chip design and control are discussed.
Thangamuthu, Madasamy; Gabriel, Willimann Eric; Santschi, Christian; Martin, Olivier J F
2018-03-07
Practice oriented point-of-care diagnostics require easy-to-handle, miniaturized, and low-cost analytical tools. In a novel approach, screen printed carbon electrodes (SPEs), which were functionalized with nanomaterials, are employed for selective measurements of bilirubin, which is an important biomarker for jaundice. Multi-walled carbon nanotubes (MWCNT) and graphene separately deposited on SPEs provide the core of an electrochemical sensor for bilirubin. The electrocatalytic activity towards bilirubin oxidation (bilirubin to biliverdin) was observed at +0.25 V. In addition, a further peak corresponding to the electrochemical conversion of biliverdin into purpurin appeared at +0.48 V. When compared to MWCNT, the graphene type shows a 3-fold lower detection limit (0.3 ± 0.022 nM and 0.1 ± 0.018 nM, respectively), moreover, the graphene type exhibits a larger linear range (0.1-600 µM) than MWCNT (0.5-500 µM) with a two-fold better sensitivity, i.e., 30 nA µM -1 cm -2 , and 15 nA µM -1 cm -2 , respectively. The viability is validated through measurements of bilirubin in blood serum samples and the selectivity is ensured by inhibiting common interfering biological substrates using an ionic nafion membrane. The presented approach enables the design and implementation of low cost and miniaturized electrochemical sensors.
Tao, L; Wilson, E C F; Wareham, N J; Sandbæk, A; Rutten, G E H M; Lauritzen, T; Khunti, K; Davies, M J; Borch-Johnsen, K; Griffin, S J; Simmons, R K
2015-01-01
Aims To examine the short- and long-term cost-effectiveness of intensive multifactorial treatment compared with routine care among people with screen-detected Type 2 diabetes. Methods Cost–utility analysis in ADDITION-UK, a cluster-randomized controlled trial of early intensive treatment in people with screen-detected diabetes in 69 UK general practices. Unit treatment costs and utility decrement data were taken from published literature. Accumulated costs and quality-adjusted life years (QALYs) were calculated using ADDITION-UK data from 1 to 5 years (short-term analysis, n = 1024); trial data were extrapolated to 30 years using the UKPDS outcomes model (version 1.3) (long-term analysis; n = 999). All costs were transformed to the UK 2009/10 price level. Results Adjusted incremental costs to the NHS were £285, £935, £1190 and £1745 over a 1-, 5-, 10- and 30-year time horizon, respectively (discounted at 3.5%). Adjusted incremental QALYs were 0.0000, – 0.0040, 0.0140 and 0.0465 over the same time horizons. Point estimate incremental cost-effectiveness ratios (ICERs) suggested that the intervention was not cost-effective although the ratio improved over time: the ICER over 10 years was £82 250, falling to £37 500 over 30 years. The ICER fell below £30 000 only when the intervention cost was below £631 per patient: we estimated the cost at £981. Conclusion Given conventional thresholds of cost-effectiveness, the intensive treatment delivered in ADDITION was not cost-effective compared with routine care for individuals with screen-detected diabetes in the UK. The intervention may be cost-effective if it can be delivered at reduced cost. PMID:25661661
Ngeow, Joanne; Liu, Chang; Zhou, Ke; Frick, Kevin D; Matchar, David B; Eng, Charis
2015-08-10
Cowden syndrome (CS) is an autosomal dominant disorder characterized by benign and malignant tumors. One-quarter of patients who are diagnosed with CS have pathogenic germline PTEN mutations, which increase the risk of the development of breast, thyroid, uterine, renal, and other cancers. PTEN testing and regular, intensive cancer surveillance allow for early detection and treatment of these cancers for mutation-positive patients and their relatives. Individual CS-related features, however, occur commonly in the general population, making it challenging for clinicians to identify CS-like patients to offer PTEN testing. We calculated the cost per mutation detected and analyzed the cost-effectiveness of performing selected PTEN testing among CS-like patients using a semi-quantitative score (the PTEN Cleveland Clinic [CC] score) compared with existing diagnostic criteria. In our model, first-degree relatives of the patients with detected PTEN mutations are offered PTEN testing. All individuals with detected PTEN mutations are offered cancer surveillance. CC score at a threshold of 15 (CC15) costs from $3,720 to $4,573 to detect one PTEN mutation, which is the most inexpensive among the different strategies. At base-case, CC10 is the most cost-effective strategy for female patients who are younger than 40 years, and CC15 is the most cost-effective strategy for female patients who are between 40 and 60 years of age and male patients of all ages. In sensitivity analyses, CC15 is robustly the most cost-effective strategy for probands who are younger than 60 years. Use of the CC score as a clinical risk calculator is a cost-effective prescreening method to identify CS-like patients for PTEN germline testing. © 2015 by American Society of Clinical Oncology.
A high-throughput microRNA expression profiling system.
Guo, Yanwen; Mastriano, Stephen; Lu, Jun
2014-01-01
As small noncoding RNAs, microRNAs (miRNAs) regulate diverse biological functions, including physiological and pathological processes. The expression and deregulation of miRNA levels contain rich information with diagnostic and prognostic relevance and can reflect pharmacological responses. The increasing interest in miRNA-related research demands global miRNA expression profiling on large numbers of samples. We describe here a robust protocol that supports high-throughput sample labeling and detection on hundreds of samples simultaneously. This method employs 96-well-based miRNA capturing from total RNA samples and on-site biochemical reactions, coupled with bead-based detection in 96-well format for hundreds of miRNAs per sample. With low-cost, high-throughput, high detection specificity, and flexibility to profile both small and large numbers of samples, this protocol can be adapted in a wide range of laboratory settings.
Biomarker detection for disease diagnosis using cost-effective microfluidic platforms.
Sanjay, Sharma T; Fu, Guanglei; Dou, Maowei; Xu, Feng; Liu, Rutao; Qi, Hao; Li, XiuJun
2015-11-07
Early and timely detection of disease biomarkers can prevent the spread of infectious diseases, and drastically decrease the death rate of people suffering from different diseases such as cancer and infectious diseases. Because conventional diagnostic methods have limited application in low-resource settings due to the use of bulky and expensive instrumentation, simple and low-cost point-of-care diagnostic devices for timely and early biomarker diagnosis is the need of the hour, especially in rural areas and developing nations. The microfluidics technology possesses remarkable features for simple, low-cost, and rapid disease diagnosis. There have been significant advances in the development of microfluidic platforms for biomarker detection of diseases. This article reviews recent advances in biomarker detection using cost-effective microfluidic devices for disease diagnosis, with the emphasis on infectious disease and cancer diagnosis in low-resource settings. This review first introduces different microfluidic platforms (e.g. polymer and paper-based microfluidics) used for disease diagnosis, with a brief description of their common fabrication techniques. Then, it highlights various detection strategies for disease biomarker detection using microfluidic platforms, including colorimetric, fluorescence, chemiluminescence, electrochemiluminescence (ECL), and electrochemical detection. Finally, it discusses the current limitations of microfluidic devices for disease biomarker detection and future prospects.
Development of a low-cost detection method for miRNA microarray.
Li, Wei; Zhao, Botao; Jin, Youxin; Ruan, Kangcheng
2010-04-01
MicroRNA (miRNA) microarray is a powerful tool to explore the expression profiling of miRNA. The current detection method used in miRNA microarray is mainly fluorescence based, which usually requires costly detection system such as laser confocal scanner of tens of thousands of dollars. Recently, we developed a low-cost yet sensitive detection method for miRNA microarray based on enzyme-linked assay. In this approach, the biotinylated miRNAs were captured by the corresponding oligonucleotide probes immobilized on microarray slide; and then the biotinylated miRNAs would capture streptavidin-conjugated alkaline phosphatase. A purple-black precipitation on each biotinylated miRNA spot was produced by the enzyme catalytic reaction. It could be easily detected by a charge-coupled device digital camera mounted on a microscope, which lowers the detection cost more than 100 fold compared with that of fluorescence method. Our data showed that signal intensity of the spot correlates well with the biotinylated miRNA concentration and the detection limit for miRNAs is at least 0.4 fmol and the detection dynamic range spans about 2.5 orders of magnitude, which is comparable to that of fluorescence method.
Veli, Muhammed; Ozcan, Aydogan
2018-03-27
We present a cost-effective and portable platform based on contact lenses for noninvasively detecting Staphylococcus aureus, which is part of the human ocular microbiome and resides on the cornea and conjunctiva. Using S. aureus-specific antibodies and a surface chemistry protocol that is compatible with human tears, contact lenses are designed to specifically capture S. aureus. After the bacteria capture on the lens and right before its imaging, the captured bacteria are tagged with surface-functionalized polystyrene microparticles. These microbeads provide sufficient signal-to-noise ratio for the quantification of the captured bacteria on the contact lens, without any fluorescent labels, by 3D imaging of the curved surface of each lens using only one hologram taken with a lens-free on-chip microscope. After the 3D surface of the contact lens is computationally reconstructed using rotational field transformations and holographic digital focusing, a machine learning algorithm is employed to automatically count the number of beads on the lens surface, revealing the count of the captured bacteria. To demonstrate its proof-of-concept, we created a field-portable and cost-effective holographic microscope, which weighs 77 g, controlled by a laptop. Using daily contact lenses that are spiked with bacteria, we demonstrated that this computational sensing platform provides a detection limit of ∼16 bacteria/μL. This contact-lens-based wearable sensor can be broadly applicable to detect various bacteria, viruses, and analytes in tears using a cost-effective and portable computational imager that might be used even at home by consumers.
A facile low-cost enzymatic paper-based assay for the determination of urine creatinine.
Talalak, Kwanrutai; Noiphung, Julaluk; Songjaroen, Temsiri; Chailapakul, Orawon; Laiwattanapaisal, Wanida
2015-11-01
Creatinine is one of many markers used to investigate kidney function. This paper describes a low-cost enzymatic paper-based analytical device (enz-PAD) for determining urine creatinine. The disposable dead volumes of creatinine enzyme reagents from an automatic analyser cassette were utilised. Whatman No. 3 paper was cut into long rectangular shapes (4×40 mm(2)) on which the enzyme reagents, R1 and R2, were adsorbed in two consecutive regions. The assay was performed by immersing test strips into urine samples contained in microwells to allow creatinine in the sample to react with immobilised active ingredients and, then, traverse via capillary action to the detection area where chromogen products accumulated. The method is based on hydrogen peroxide (H2O2) formation via creatinine conversion using creatininase, creatinase, and sarcosine oxidase. The liberated H2O2 reacts with 4-aminophenazone and 2,4,6-triiodo-3-hydroxybenzoic acid to form quinoneimine with a pink-red colour at the detection zone. The linear range of the creatinine assay was 2.5-25 mg dL(-1) (r(2)=0.983), and the detection limit was 2.0 mg dL(-1). The colorimetric enz-PAD for the creatinine assay was highly correlated with a conventional alkaline picrate method when real urine samples were evaluated (r(2)=0.977; n=40). This simple and nearly zero-cost paper-based device provides a novel alternative method for screening urinary creatinine and will be highly beneficial for developing countries. Copyright © 2015 Elsevier B.V. All rights reserved.
Optimal Attack Strategies Subject to Detection Constraints Against Cyber-Physical Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, Yuan; Kar, Soummya; Moura, Jose M. F.
This paper studies an attacker against a cyberphysical system (CPS) whose goal is to move the state of a CPS to a target state while ensuring that his or her probability of being detected does not exceed a given bound. The attacker’s probability of being detected is related to the nonnegative bias induced by his or her attack on the CPS’s detection statistic. We formulate a linear quadratic cost function that captures the attacker’s control goal and establish constraints on the induced bias that reflect the attacker’s detection-avoidance objectives. When the attacker is constrained to be detected at the false-alarmmore » rate of the detector, we show that the optimal attack strategy reduces to a linear feedback of the attacker’s state estimate. In the case that the attacker’s bias is upper bounded by a positive constant, we provide two algorithms – an optimal algorithm and a sub-optimal, less computationally intensive algorithm – to find suitable attack sequences. Lastly, we illustrate our attack strategies in numerical examples based on a remotely-controlled helicopter under attack.« less
Optimal Attack Strategies Subject to Detection Constraints Against Cyber-Physical Systems
Chen, Yuan; Kar, Soummya; Moura, Jose M. F.
2017-03-31
This paper studies an attacker against a cyberphysical system (CPS) whose goal is to move the state of a CPS to a target state while ensuring that his or her probability of being detected does not exceed a given bound. The attacker’s probability of being detected is related to the nonnegative bias induced by his or her attack on the CPS’s detection statistic. We formulate a linear quadratic cost function that captures the attacker’s control goal and establish constraints on the induced bias that reflect the attacker’s detection-avoidance objectives. When the attacker is constrained to be detected at the false-alarmmore » rate of the detector, we show that the optimal attack strategy reduces to a linear feedback of the attacker’s state estimate. In the case that the attacker’s bias is upper bounded by a positive constant, we provide two algorithms – an optimal algorithm and a sub-optimal, less computationally intensive algorithm – to find suitable attack sequences. Lastly, we illustrate our attack strategies in numerical examples based on a remotely-controlled helicopter under attack.« less
Amperometric immunosensor for rapid detection of Mycobacterium tuberculosis
NASA Astrophysics Data System (ADS)
Hiraiwa, Morgan; Kim, Jong-Hoon; Lee, Hyun-Boo; Inoue, Shinnosuke; Becker, Annie L.; Weigel, Kris M.; Cangelosi, Gerard A.; Lee, Kyong-Hoon; Chung, Jae-Hyun
2015-05-01
Tuberculosis (TB) has been a major public health problem, which can be better controlled by using accurate and rapid diagnosis in low-resource settings. A simple, portable, and sensitive detection method is required for point-of-care (POC) settings. This paper studies an amperometric biosensor using a microtip immunoassay for a rapid and low-cost detection of Mycobacterium tuberculosis (MTB) in sputum. MTB in sputum is specifically captured on the functionalized microtip surface and detected by electric current. According to the numerical study, the current signal on the microtip surface is linearly changed with increasing immersion depth. Using a reference microtip, the immersion depth is compensated for a sensing microtip. On the microtip surface, target bacteria are concentrated and organized by a coffee-ring effect, which amplifies the electric current. To enhance the signal-to-noise ratio, both the sample processing and rinsing steps are presented with the use of deionized water as a medium for the amperometric measurement. When applied to cultured MTB cells spiked into human sputum, the detection limit was 100 CFU mL-1, comparable to a more labor-intensive fluorescence detection method reported previously.
Liu, Haisheng; Ma, Linbin; Ma, Changbei; Du, Junyan; Wang, Meilan; Wang, Kemin
2016-11-18
A new quencher-free Hg 2+ ion assay method was developed based on polymerase-assisted photoinduced electron transfer (PIET). In this approach, a probe is designed with a mercury ion recognition sequence (MRS) that is composed of two T-rich functional areas separated by a spacer of random bases at the 3'-end, and a sequence of stacked cytosines at the 5'-end, to which a fluorescein (FAM) is attached. Upon addition of Hg 2+ ions into this sensing system, the MRS folds into a hairpin structure at the 3'-end with Hg 2+ -mediated base pairs. In the presence of DNA polymerase, it will catalyze the extension reaction, resulting in the formation of stacked guanines, which will instantly quench the fluorescence of FAM through PIET. Under optimal conditions, the limit of detection for Hg 2+ ions was estimated to be 5 nM which is higher than the US Environmental Protection Agency (EPA) standard limit. In addition, no labeling with a quencher was requiring, and the present method is fairly simple, fast and low cost. It is expected that this cost-effective fluorescence method might hold considerable potential in the detection of Hg 2+ ions in real biological and environmental samples.
Compact low-cost detection electronics for optical coherence imaging
Akcay, A. C.; Lee, K. S.; Furenlid, L. R.; Costa, M. A.; Rolland, J. P.
2015-01-01
A compact and low-cost detection electronics scheme for optical coherence imaging is demonstrated. The performance of the designed electronics is analyzed in comparison to a commercial lock-in amplifier of equal bandwidth. Images of a fresh-onion sample are presented for each detection configuration. PMID:26617422
Lin, Xiaodong; Liu, Yaqing; Deng, Jiankang; Lyu, Yanlong; Qian, Pengcheng; Li, Yunfei; Wang, Shuo
2018-02-21
The integration of multiple DNA logic gates on a universal platform to implement advance logic functions is a critical challenge for DNA computing. Herein, a straightforward and powerful strategy in which a guanine-rich DNA sequence lighting up a silver nanocluster and fluorophore was developed to construct a library of logic gates on a simple DNA-templated silver nanoclusters (DNA-AgNCs) platform. This library included basic logic gates, YES, AND, OR, INHIBIT, and XOR, which were further integrated into complex logic circuits to implement diverse advanced arithmetic/non-arithmetic functions including half-adder, half-subtractor, multiplexer, and demultiplexer. Under UV irradiation, all the logic functions could be instantly visualized, confirming an excellent repeatability. The logic operations were entirely based on DNA hybridization in an enzyme-free and label-free condition, avoiding waste accumulation and reducing cost consumption. Interestingly, a DNA-AgNCs-based multiplexer was, for the first time, used as an intelligent biosensor to identify pathogenic genes, E. coli and S. aureus genes, with a high sensitivity. The investigation provides a prototype for the wireless integration of multiple devices on even the simplest single-strand DNA platform to perform diverse complex functions in a straightforward and cost-effective way.
Novel biomarkers of acute kidney injury: Evaluation and evidence in urologic surgery
Schmid, Marianne; Dalela, Deepansh; Tahbaz, Rana; Langetepe, Jessica; Randazzo, Marco; Dahlem, Roland; Fisch, Margit; Trinh, Quoc-Dien; Chun, Felix K-H
2015-01-01
Patients undergoing urologic surgery are at risk of acute kidney injury (AKI) and consequently long-term deterioration in renal function. AKI is further associated with significantly higher odds of perioperative complications, prolonged hospital stay, higher mortality and costs. Therefore, better awareness and detection of AKI, as well as identification of AKI determinants in the urological surgery setting is warranted to pre-empt and mitigate further deterioration of renal function in patients at special risk. New consensus criteria provide precise definitions of diagnosis and description of the severity of AKI. However, they rely on serum creatinine (SCr), which is known to be an inaccurate marker of early changes in renal function. Therefore, several new urinary and serum biomarkers promise to address the gap associated with the use of SCr. Novel biomarkers may complement SCr measurement or most likely improve the diagnostic accuracy of AKI when used in combinations. However, novel biomarkers have to prove their clinical applicability, accuracy, and cost effectiveness prior to implementation into clinical practice. Most preferably, novel biomarkers should help to positively improve a patient’s long-term renal functional outcomes. The purpose of this review is to discuss currently available biomarkers and to review their clinical evidence within urologic surgery settings. PMID:25949930
Health economics evaluation of a gastric cancer early detection and treatment program in China.
Li, Dan; Yuan, Yuan; Sun, Li-Ping; Fang, Xue; Zhou, Bao-Sen
2014-01-01
To use health economics methodology to assess the screening program on gastric cancer in Zhuanghe, China, so as to provide the basis for health decision on expanding the program of early detection and treatment. The expense of an early detection and treatment program for gastric cancer in patients found by screening, and also costs of traditional treatment in a hospital of Zhuanghe were assessed. Three major techniques of medical economics, namely cost-effective analysis (CEA), cost-benefit analysis (CBA) and cost-utility analysis (CUA), were used to assess the screening program. RESULTS from CEA showed that investing every 25, 235 Yuan on screening program in Zhuanghe area, one gastric cancer patient could be saved. Data from CUA showed that it was cost 1, 370 Yuan per QALY saved. RESULTS from CBA showed that: the total cost was 1,945,206 Yuan with a benefit as 8,669,709 Yuan and an CBR of 4.46. The early detection and treatment program of gastric cancer appears economic and society-beneficial. We suggest that it should be carry out in more high risk areas for gastric cancer.
Dervisevic, Muamer; Senel, Mehmet; Sagir, Tugba; Isik, Sevim
2017-04-15
The detection of cancer cells through important molecular recognition target such as sialic acid is significant for the clinical diagnosis and treatment. There are many electrochemical cytosensors developed for cancer cells detection but most of them have complicated fabrication processes which results in poor reproducibility and reliability. In this study, a simple, low-cost, and highly sensitive electrochemical cytosensor was designed based on boronic acid-functionalized polythiophene. In cytosensors fabrication simple single-step procedure was used which includes coating pencil graphite electrode (PGE) by means of electro-polymerization of 3-Thienyl boronic acid and Thiophen. Electrochemical impedance spectroscopy and cyclic voltammetry were used as an analytical methods to optimize and measure analytical performances of PGE/P(TBA 0.5 Th 0.5 ) based electrode. Cytosensor showed extremely good analytical performances in detection of cancer cells with linear rage of 1×10 1 to 1×10 6 cellsmL -1 exhibiting low detection limit of 10 cellsmL -1 and incubation time of 10min. Next to excellent analytical performances, it showed high selectivity towards AGS cancer cells when compared to HEK 293 normal cells and bone marrow mesenchymal stem cells (BM-hMSCs). This method is promising for future applications in early stage cancer diagnosis. Copyright © 2016 Elsevier B.V. All rights reserved.
Choi, Jane Ru; Yong, Kar Wey; Tang, Ruihua; Gong, Yan; Wen, Ting; Yang, Hui; Li, Ang; Chia, Yook Chin; Pingguan-Murphy, Belinda; Xu, Feng
2017-01-01
Paper-based devices have been broadly used for the point-of-care detection of dengue viral nucleic acids due to their simplicity, cost-effectiveness, and readily observable colorimetric readout. However, their moderate sensitivity and functionality have limited their applications. Despite the above-mentioned advantages, paper substrates are lacking in their ability to control fluid flow, in contrast to the flow control enabled by polymer substrates (e.g., agarose) with readily tunable pore size and porosity. Herein, taking the benefits from both materials, the authors propose a strategy to create a hybrid substrate by incorporating agarose into the test strip to achieve flow control for optimal biomolecule interactions. As compared to the unmodified test strip, this strategy allows sensitive detection of targets with an approximately tenfold signal improvement. Additionally, the authors showcase the potential of functionality improvement by creating multiple test zones for semi-quantification of targets, suggesting that the number of visible test zones is directly proportional to the target concentration. The authors further demonstrate the potential of their proposed strategy for clinical assessment by applying it to their prototype sample-to-result test strip to sensitively and semi-quantitatively detect dengue viral RNA from the clinical blood samples. This proposed strategy holds significant promise for detecting various targets for diverse future applications. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Lince-Deroche, Naomi; Phiri, Jane; Michelow, Pam; Smith, Jennifer S.; Firnhaber, Cindy
2015-01-01
Background South Africa has high rates of HIV and HPV and high incidence and mortality from cervical cancer. However, cervical cancer is largely preventable when early screening and treatment are available. We estimate the costs and cost-effectiveness of conventional cytology (Pap), visual inspection with acetic acid (VIA) and HPV DNA testing for detecting cases of CIN2+ among HIV-infected women currently taking antiretroviral treatment at a public HIV clinic in Johannesburg, South Africa. Methods Method effectiveness was derived from a validation study completed at the clinic. Costs were estimated from the provider perspective using micro-costing between June 2013-April 2014. Capital costs were annualized using a discount rate of 3%. Two different service volume scenarios were considered. Threshold analysis was used to explore the potential for reducing the cost of HPV DNA testing. Results VIA was least costly in both scenarios. In the higher volume scenario, the average cost per procedure was US$ 3.67 for VIA, US$ 8.17 for Pap and US$ 54.34 for HPV DNA. Colposcopic biopsies cost on average US$ 67.71 per procedure. VIA was least sensitive but most cost-effective at US$ 17.05 per true CIN2+ case detected. The cost per case detected for Pap testing was US$ 130.63 using a conventional definition for positive results and US$ 187.52 using a more conservative definition. HPV DNA testing was US$ 320.09 per case detected. Colposcopic biopsy costs largely drove the total and per case costs. A 71% reduction in HPV DNA screening costs would make it competitive with the conservative Pap definition. Conclusions Women need access to services which meet their needs and address the burden of cervical dysplasia and cancer in this region. Although most cost-effective, VIA may require more frequent screening due to low sensitivity, an important consideration for an HIV-positive population with increased risk for disease progression. PMID:26569487
Lince-Deroche, Naomi; Phiri, Jane; Michelow, Pam; Smith, Jennifer S; Firnhaber, Cindy
2015-01-01
South Africa has high rates of HIV and HPV and high incidence and mortality from cervical cancer. However, cervical cancer is largely preventable when early screening and treatment are available. We estimate the costs and cost-effectiveness of conventional cytology (Pap), visual inspection with acetic acid (VIA) and HPV DNA testing for detecting cases of CIN2+ among HIV-infected women currently taking antiretroviral treatment at a public HIV clinic in Johannesburg, South Africa. Method effectiveness was derived from a validation study completed at the clinic. Costs were estimated from the provider perspective using micro-costing between June 2013-April 2014. Capital costs were annualized using a discount rate of 3%. Two different service volume scenarios were considered. Threshold analysis was used to explore the potential for reducing the cost of HPV DNA testing. VIA was least costly in both scenarios. In the higher volume scenario, the average cost per procedure was US$ 3.67 for VIA, US$ 8.17 for Pap and US$ 54.34 for HPV DNA. Colposcopic biopsies cost on average US$ 67.71 per procedure. VIA was least sensitive but most cost-effective at US$ 17.05 per true CIN2+ case detected. The cost per case detected for Pap testing was US$ 130.63 using a conventional definition for positive results and US$ 187.52 using a more conservative definition. HPV DNA testing was US$ 320.09 per case detected. Colposcopic biopsy costs largely drove the total and per case costs. A 71% reduction in HPV DNA screening costs would make it competitive with the conservative Pap definition. Women need access to services which meet their needs and address the burden of cervical dysplasia and cancer in this region. Although most cost-effective, VIA may require more frequent screening due to low sensitivity, an important consideration for an HIV-positive population with increased risk for disease progression.
Atia, Mary A; Patel, Neal C; Ratuapli, Shiva K; Boroff, Erika S; Crowell, Michael D; Gurudu, Suryakanth R; Faigel, Douglas O; Leighton, Jonathan A; Ramirez, Francisco C
2015-08-01
The frequency of nonneoplastic polypectomy (NNP) and its impact on the polyp detection rate (PDR) is unknown. The correlation between NNP and adenoma detection rate (ADR) and its impact on the cost of colonoscopy has not been investigated. To determine the rate of NNP in screening colonoscopy, the impact of NNP on the PDR, and the correlation of NNP with ADR. The increased cost of NNP during screening colonoscopy also was calculated. We reviewed all screening colonoscopies. PDR and ADR were calculated. We then calculated a nonneoplastic polyp detection rate (patients with ≥1 nonneoplastic polyp). Tertiary-care referral center. Patients who underwent screening colonoscopies from 2010 to 2011. Colonoscopy. ADR, PDR, NNP rate. A total of 1797 colonoscopies were reviewed. Mean (±standard deviation) PDR was 47.7%±12.0%, and mean ADR was 27.3%±6.9%. The overall NNP rate was 10.4%±7.1%, with a range of 2.4% to 28.4%. Among all polypectomies (n=2061), 276 were for nonneoplastic polyps (13.4%). Endoscopists with a higher rate of nonneoplastic polyp detection were more likely to detect an adenoma (odds ratio 1.58; 95% confidence interval, 1.1-1.2). With one outlier excluded, there was a strong correlation between ADR and NNP (r=0.825; P<.001). The increased cost of removal of nonneoplastic polyps was $32,963. Retrospective study. There is a strong correlation between adenoma detection and nonneoplastic polyp detection. The etiology is unclear, but nonneoplastic polyp detection rate may inflate the PDR for some endoscopists. NNP also adds an increased cost. Increasing the awareness of endoscopic appearances through advanced imaging techniques of normal versus neoplastic tissue may be an area to improve cost containment in screening colonoscopy. Copyright © 2015 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.
Hunter, Sara A; Morris, Colleen; Nelson, Karl; Snyder, Brandon J; Poulton, Thomas B
2017-05-01
The purpose of this study was to determine whether digital breast tomosynthesis (DBT) is a cost-effective alternative to full-field digital mammography (FFDM) for both Medicare and privately insured patients undergoing screening mammography. A retrospective data analysis was performed between July 15, 2013, and July 14, 2014, with data on women presenting for screening mammography that included any additional radiologic workup (n = 6319). Patients chose to undergo DBT or FFDM on the basis of personal preference, physician suggestion, and cost difference. The summation of findings over the 1-year period were used to calculate recall rates, cancer detection rates, and billing costs for a regional private insurer and Medicare. Data from the 6319 patients who participated were divided: 3655 patients underwent DBT, and 2664 underwent FFDM during the year of screening. Private insurance billing cost $2.9 million, and Medicare cost $1.2 million for screening, follow-up imaging, and radiologic procedures. Per-person costs were approximately $40 higher for the DBT group using both forms of insurance. However, cost per cancer detected was lower in the DBT group for both private and governmental insurance, leading to potentially $3.7 million and $899,000 saved per 100 cancers found. After standardization of the difference in cancer detection rates between the two groups, DBT was a cost-equivalent alternative to FFDM for private insurance billing but was a cost-inefficient alternative with respect to Medicare costs. In a community-based setting, DBT is a cost-equivalent or potentially cost-effective alternative to FFDM and has the capacity for improving cancer detection and recall rates.
Ayres, Alice C; Whitty, Jennifer A; Ellwood, David A
2014-10-01
Currently, noninvasive prenatal testing (NIPT) is only recommended in high-risk women following conventional Down syndrome (DS) screening, and it has not yet been included in the Australian DS screening program. To evaluate the cost-effectiveness of different strategies of NIPT for DS screening in comparison with current practice. A decision-analytic approach modelled a theoretical cohort of 300,000 singleton pregnancies. The strategies compared were the following: current practice, NIPT as a second-tier investigation, NIPT only in women >35 years, NIPT only in women >40 years and NIPT for all women. The direct costs (low and high estimates) were derived using both health system costs and patient out-of-pocket expenses. The number of DS cases detected and procedure-related losses (PRL) were compared between strategies. The incremental cost per case detected was the primary measure of cost-effectiveness. Universal NIPT costs an additional $134,636,832 compared with current practice, but detects 123 more DS cases (at an incremental cost of $1,094,608 per case) and avoids 90 PRL. NIPT for women >40 years was the most cost-effective strategy, costing an incremental $81,199 per additional DS case detected and avoiding 95 PRL. The cost of NIPT needs to decrease significantly if it is to replace current practice on a purely cost-effectiveness basis. However, it may be beneficial to use NIPT as first-line screening in selected high-risk patients. Further evaluation is needed to consider the longer-term costs and benefits of screening. © 2014 The Royal Australian and New Zealand College of Obstetricians and Gynaecologists.
Optimal network alignment with graphlet degree vectors.
Milenković, Tijana; Ng, Weng Leong; Hayes, Wayne; Przulj, Natasa
2010-06-30
Important biological information is encoded in the topology of biological networks. Comparative analyses of biological networks are proving to be valuable, as they can lead to transfer of knowledge between species and give deeper insights into biological function, disease, and evolution. We introduce a new method that uses the Hungarian algorithm to produce optimal global alignment between two networks using any cost function. We design a cost function based solely on network topology and use it in our network alignment. Our method can be applied to any two networks, not just biological ones, since it is based only on network topology. We use our new method to align protein-protein interaction networks of two eukaryotic species and demonstrate that our alignment exposes large and topologically complex regions of network similarity. At the same time, our alignment is biologically valid, since many of the aligned protein pairs perform the same biological function. From the alignment, we predict function of yet unannotated proteins, many of which we validate in the literature. Also, we apply our method to find topological similarities between metabolic networks of different species and build phylogenetic trees based on our network alignment score. The phylogenetic trees obtained in this way bear a striking resemblance to the ones obtained by sequence alignments. Our method detects topologically similar regions in large networks that are statistically significant. It does this independent of protein sequence or any other information external to network topology.
Investigating and understanding fouling in a planar setup using ultrasonic methods.
Wallhäusser, E; Hussein, M A; Becker, T
2012-09-01
Fouling is an unwanted deposit on heat transfer surfaces and occurs regularly in foodstuff heat exchangers. Fouling causes high costs because cleaning of heat exchangers has to be carried out and cleaning success cannot easily be monitored. Thus, used cleaning cycles in foodstuff industry are usually too long leading to high costs. In this paper, a setup is described with which it is possible, first, to produce dairy protein fouling similar to the one found in industrial heat exchangers and, second, to detect the presence and absence of such fouling using an ultrasonic based measuring method. The developed setup resembles a planar heat exchanger in which fouling can be made and cleaned reproducible. Fouling presence, absence, and cleaning progress can be monitored by using an ultrasonic detection unit. The setup is described theoretically based on electrical and mechanical lumped circuits to derive the wave equation and the transfer function to perform a sensitivity analysis. Sensitivity analysis was done to determine influencing quantities and showed that fouling is measurable. Also, first experimental results are compared with results from sensitivity analysis.
Facile fabrication of CNT-based chemical sensor operating at room temperature
NASA Astrophysics Data System (ADS)
Sheng, Jiadong; Zeng, Xian; Zhu, Qi; Yang, Zhaohui; Zhang, Xiaohua
2017-12-01
This paper describes a simple, low cost and effective route to fabricate CNT-based chemical sensors, which operate at room temperature. Firstly, the incorporation of silk fibroin in vertically aligned CNT arrays (CNTA) obtained through a thermal chemical vapor deposition (CVD) method makes the direct removal of CNT arrays from substrates without any rigorous acid or sonication treatment feasible. Through a simple one-step in situ polymerization of anilines, the functionalization of CNT arrays with polyaniline (PANI) significantly improves the sensing performance of CNT-based chemical sensors in detecting ammonia (NH3) and hydrogen chloride (HCl) vapors. Chemically modified CNT arrays also show responses to organic vapors like menthol, ethyl acetate and acetone. Although the detection limits of chemically modified CNT-based chemical sensors are of the same orders of magnitudes reported in previous studies, these CNT-based chemical sensors show advantages of simplicity, low cost and energy efficiency in preparation and fabrication of devices. Additionally, a linear relationship between the relative sensitivity and concentration of analyte makes precise estimations on the concentrations of trace chemical vapors possible.
Cost-effectiveness analysis in melanoma detection: A transition model applied to dermoscopy.
Tromme, Isabelle; Legrand, Catherine; Devleesschauwer, Brecht; Leiter, Ulrike; Suciu, Stefan; Eggermont, Alexander; Sacré, Laurine; Baurain, Jean-François; Thomas, Luc; Beutels, Philippe; Speybroeck, Niko
2016-11-01
The main aim of this study is to demonstrate how our melanoma disease model (MDM) can be used for cost-effectiveness analyses (CEAs) in the melanoma detection field. In particular, we used the data of two cohorts of Belgian melanoma patients to investigate the cost-effectiveness of dermoscopy. A MDM, previously constructed to calculate the melanoma burden, was slightly modified to be suitable for CEAs. Two cohorts of patients entered into the model to calculate morbidity, mortality and costs. These cohorts were constituted by melanoma patients diagnosed by dermatologists adequately, or not adequately, trained in dermoscopy. Effectiveness and costs were calculated for each cohort and compared. Effectiveness was expressed in quality-adjusted life years (QALYs), a composite measure depending on melanoma-related morbidity and mortality. Costs included costs of treatment and follow-up as well as costs of detection in non-melanoma patients and costs of excision and pathology of benign lesions excised to rule out melanoma. The result of our analysis concluded that melanoma diagnosis by dermatologists adequately trained in dermoscopy resulted in both a gain of QALYs (less morbidity and/or mortality) and a reduction in costs. This study demonstrates how our MDM can be used in CEAs in the melanoma detection field. The model and the methodology suggested in this paper were applied to two cohorts of Belgian melanoma patients. Their analysis concluded that adequate dermoscopy training is cost-effective. The results should be confirmed by a large-scale randomised study. Copyright © 2016 Elsevier Ltd. All rights reserved.
Paul, K Brince; Singh, Vikrant; Vanjari, Siva Rama Krishna; Singh, Shiv Govind
2017-02-15
Ovarian cancer is the most leading cause of cancer-related death in women . The carcinoma antigen-125, which is found on the surface of many ovarian cancer cells is known to be a gold standard clinical biomarker associated with life-threatening gynecological malignancy. In this work, we demonstrate a novel biosensor platform based on multiwalled carbon nanotubes embedded zinc oxide nanowire for the ultrasensitive detection of carcinoma antigen-125. Label free detection of the carcinoma antigen-125 was accomplished by differential voltammetry technique that demonstrated excellent sensitivity (90.14µA/(U/mL)/cm 2 ) with a detection limit of 0.00113UmL -1 concentration. The fabricated immunosensor exhibits good performance with wider detection range (0.001UmL -1 -1kUmL -1 ), reproducibility, selectivity, acceptable stability, and thus is a potential cost-effective methodology for point-of-care diagnosis. The multiwalled carbon nanotubes (MWCNTs) embedded highly oriented zinc oxide (ZnO) nanowires were synthesized by simple, low cost electrospinning technique. Compared to pure ZnO nanowires, electrochemical activity of MWCNTs embedded ZnO nanowires was found to be much higher. The calcination temperature was optimized to avoid any decomposition of the CNTs and to obtain multiwalled carbon nanotubes embedded highly crystalline ZnO nanowires. The salient feature of this biosensing platform is that one step calcination process is enough to create the functional groups on MWCNT-ZnO nanowire surface that are effective for the covalent conjugation of antibody without further surface modification. To the best of our knowledge, this is the first report on MWCNT-ZnO nanowire based immunosensor explored for the detection of cancer biomarker. Copyright © 2016 Elsevier B.V. All rights reserved.
Anomaly Detection for Next-Generation Space Launch Ground Operations
NASA Technical Reports Server (NTRS)
Spirkovska, Lilly; Iverson, David L.; Hall, David R.; Taylor, William M.; Patterson-Hine, Ann; Brown, Barbara; Ferrell, Bob A.; Waterman, Robert D.
2010-01-01
NASA is developing new capabilities that will enable future human exploration missions while reducing mission risk and cost. The Fault Detection, Isolation, and Recovery (FDIR) project aims to demonstrate the utility of integrated vehicle health management (IVHM) tools in the domain of ground support equipment (GSE) to be used for the next generation launch vehicles. In addition to demonstrating the utility of IVHM tools for GSE, FDIR aims to mature promising tools for use on future missions and document the level of effort - and hence cost - required to implement an application with each selected tool. One of the FDIR capabilities is anomaly detection, i.e., detecting off-nominal behavior. The tool we selected for this task uses a data-driven approach. Unlike rule-based and model-based systems that require manual extraction of system knowledge, data-driven systems take a radically different approach to reasoning. At the basic level, they start with data that represent nominal functioning of the system and automatically learn expected system behavior. The behavior is encoded in a knowledge base that represents "in-family" system operations. During real-time system monitoring or during post-flight analysis, incoming data is compared to that nominal system operating behavior knowledge base; a distance representing deviation from nominal is computed, providing a measure of how far "out of family" current behavior is. We describe the selected tool for FDIR anomaly detection - Inductive Monitoring System (IMS), how it fits into the FDIR architecture, the operations concept for the GSE anomaly monitoring, and some preliminary results of applying IMS to a Space Shuttle GSE anomaly.
Dai, Yifan; Wang, Chunlai; Chiu, Liang-Yuan; Abbasi, Kevin; Tolbert, Blanton S; Sauvé, Geneviève; Yen, Yun; Liu, Chung-Chiun
2018-06-01
A simple-prepare, single-use and cost-effective, in vitro biosensor for the detection of TAR DNA-binding protein 43 (TDP-43), a biomarker of neuro-degenerative disorders, was designed, manufactured and tested. This study reports the first biosensor application for the detection of TDP-43 using a novel biosensor fabrication methodology. Bioconjugation mechanism was applied by conjugating anti-TDP 43 with N-succinimidyl S-acetylthioacetate (SATA) producing a thiol-linked anti-TDP 43, which was used to directly link with gold electrode surface, minimizing the preparation steps for biosensor fabrication and simplifying the biosensor surface. The effectiveness of this bioconjugation mechanism was evaluated and confirmed by FqRRM12 protein, using nuclear magnetic resonance (NMR). The surface coverage of the electrode was analyzed by Time-of-Flight-Secondary Ion Mass Spectrometry (TOF-SIMS). Differential pulse voltammetry (DPV) was acted as the detection transduction mechanism with the use of [Fe(CN) 6 ] 3-/4- redox probe. Human TDP-43 peptide of 0.0005 µg/mL to 2 µg/mL in undiluted human serum was analyzed using this TDP-43 biosensor. Interference study of the TDP-43 biosensor using β-amyloid 42 protein and T-tau protein confirmed the specificity of this TDP-43 biosensor. This bioconjugation chemistry based approach for biosensor fabrication circumvents tedious gold surface modification and functionalization while enabling specific detection of TDP-43 in less than 1 h with a low fabrication cost of a single biosensor less than $3. Copyright © 2018 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Dwivedi, Priyanka; Das, Samaresh; Dhanekar, Saakshi
2017-04-01
This paper highlights the surface treatment of porous silicon (PSi) for enhancing the sensitivity of water vapors at room temperature. A simple and low cost technique was used for fabrication and functionalization of PSi. Spin coated polyvinyl alcohol (PVA) was used for functionalizing PSi surface. Morphological and structural studies were conducted to analyze samples using SEM and XRD/Raman spectroscopy respectively. Contact angle measurements were performed for assessing the wettability of the surfaces. PSi and functionalized PSi samples were tested as sensors in presence of different analytes like ethanol, acetone, isopropyl alcohol (IPA) and water vapors in the range of 50-500 ppm. Electrical measurements were taken from parallel aluminium electrodes fabricated on the functionalized surface, using metal mask and thermal evaporation. Functionalized PSi sensors in comparison to non-functionalized sensors depicted selective and enhanced response to water vapor at room temperature. The results portray an efficient and selective water vapor detection at room temperature.
Implementation of a microcontroller-based semi-automatic coagulator.
Chan, K; Kirumira, A; Elkateeb, A
2001-01-01
The coagulator is an instrument used in hospitals to detect clot formation as a function of time. Generally, these coagulators are very expensive and therefore not affordable by a doctors' office and small clinics. The objective of this project is to design and implement a low cost semi-automatic coagulator (SAC) prototype. The SAC is capable of assaying up to 12 samples and can perform the following tests: prothrombin time (PT), activated partial thromboplastin time (APTT), and PT/APTT combination. The prototype has been tested successfully.
Munger, Thomas M.; Wu, Li-Qun; Shen, Win K.
2014-01-01
Atrial fibrillation is the most common arrhythmia affecting patients today. Disease prevalence is increasing at an alarming rate worldwide, and is associated with often catastrophic and costly consequences, including heart failure, syncope, dementia, and stroke. Therapies including anticoagulants, anti-arrhythmic medications, devices, and non-pharmacologic procedures in the last 30 years have improved patients' functionality with the disease. Nonetheless, it remains imperative that further research into AF epidemiology, genetics, detection, and treatments continues to push forward rapidly as the worldwide population ages dramatically over the next 20 years. PMID:24474959
Daroles, Johanna; Borget, Isabelle; Suciu, Voichita; Mazouni, Chafika; Delaloge, Suzette; Balleyguier, Corinne
2017-11-01
A short-term radiologic follow-up after a benign breast biopsy or fine needle aspiration (FNA) is recommended in many guidelines. However, the current trend is to reduce imaging investigations, radiation dose and costs. The objectives of this study were to evaluate the cancer detection rate at short-term follow-up and to estimate its cost. We retrospectively assessed all consecutive patients referred to our 'one-stop' breast unit between 2004 and 2012, with a benign histological or cytological result and at least one short-term follow-up within 3-12 months after the initial diagnosis. We evaluated the number of cancers detected, as well as the mean cost to detect each cancer and per patient. About 1366 patients were eligible for this study. Ten patients were diagnosed with cancers (0.73%) at short-term follow-up; six of 10 were low-grade tumours or ductal carcinoma in situ. The cost for detecting one cancer was 19,043€, with mean cost per patient of 139€. The cancer detection rate at short-term follow-up after benign biopsy or FNA was low and was similar to that of most national screening programs. The cost of cancer detection appeared high, considering that most cancers were indolent. This suggests that radiologic follow-up could reasonably be carried out at a later point in time. Copyright © 2017 Elsevier Ltd. All rights reserved.
Ultrasensitive detection of endotoxins using computationally designed nanoMIPs.
Altintas, Zeynep; Abdin, Mohammed J; Tothill, Alexander M; Karim, Kal; Tothill, Ibtisam E
2016-09-07
Novel molecularly imprinted polymer nanoparticles (nanoMIPs) were designed for endotoxin from Escherichia coli 0111:B4, using computational modeling. The screening process based on binding energy between endotoxin and each monomer was performed with 21 commonly used monomers, resulting in the selection of itaconic acid, methacrylic acid and acrylamide as functional monomers due to their strong binding interaction with the endotoxin template. The nanoMIPs were successfully synthesized with functional groups on the outer surface to aid in the immobilization onto sensor surface. The solid phase photopolymerization approach used for the synthesis of nanoMIPs ranging from 200 to 235 nm in diameter. The limit of detection and KD were significantly improved when endotoxin samples were prepared using a novel triethylamine method. This improved the efficiency of gold nanoparticle functionalization by targeting the subunits of the endotoxin. Compared to the vancomycin MIP control, the endotoxin MIPs displayed outstanding affinity and selectivity towards the endotoxin with KD values in the range of 4.4-5.3 × 10(-10) M, with limits of detection of 0.44 ± 0.02 ng mL(-1) as determined by surface plasmon resonance (SPR) sensor when itaconic acid was used as the functional monomer. The MIP surface can be regenerated >30 times without significant loss of binding activity making this approach highly cost effective for expensive analyte templates. The combination of molecular modeling and solid phase synthesis enabled the successful synthesis of nanoMIPs capable of recognition and ultrasensitive detection of endotoxins using the highly sensitive SPR biosensor with triethylamine method. Copyright © 2016 Elsevier B.V. All rights reserved.
Hsiang, E; Little, K M; Haguma, P; Hanrahan, C F; Katamba, A; Cattamanchi, A; Davis, J L; Vassall, A; Dowdy, D
2016-09-01
Initial cost-effectiveness evaluations of Xpert(®) MTB/RIF for tuberculosis (TB) diagnosis have not fully accounted for the realities of implementation in peripheral settings. To evaluate costs and diagnostic outcomes of Xpert testing implemented at various health care levels in Uganda. We collected empirical cost data from five health centers utilizing Xpert for TB diagnosis, using an ingredients approach. We reviewed laboratory and patient records to assess outcomes at these sites and10 sites without Xpert. We also estimated incremental cost-effectiveness of Xpert testing; our primary outcome was the incremental cost of Xpert testing per newly detected TB case. The mean unit cost of an Xpert test was US$21 based on a mean monthly volume of 54 tests per site, although unit cost varied widely (US$16-58) and was primarily determined by testing volume. Total diagnostic costs were 2.4-fold higher in Xpert clinics than in non-Xpert clinics; however, Xpert only increased diagnoses by 12%. The diagnostic costs of Xpert averaged US$119 per newly detected TB case, but were as high as US$885 at the center with the lowest volume of tests. Xpert testing can detect TB cases at reasonable cost, but may double diagnostic budgets for relatively small gains, with cost-effectiveness deteriorating with lower testing volumes.
Maternal cfDNA screening for Down syndrome--a cost sensitivity analysis.
Cuckle, Howard; Benn, Peter; Pergament, Eugene
2013-07-01
This study aimed to determine the principal factors contributing to the cost of avoiding a birth with Down syndrome by using cell-free DNA (cfDNA) to replace conventional screening. A range of unit costs were assigned to each item in the screening process. Detection rates were estimated by meta-analysis and modeling. The marginal cost associated with the detection of additional cases using cfDNA was estimated from the difference in average costs divided by the difference in detection. The main factor was the unit cost of cfDNA testing. For example, replacing a combined test costing $150 with 3% false-positive rate and invasive testing at $1000, by cfDNA tests at $2000, $1500, $1000, and $500, the marginal cost is $8.0, $5.8, $3.6, and $1.4m, respectively. Costs were lower when replacing a quadruple test and higher for a 5% false-positive rate, but the relative importance of cfDNA unit cost was unchanged. A contingent policy whereby 10% to 20% women were selected for cfDNA testing by conventional screening was considerably more cost-efficient. Costs were sensitive to cfDNA uptake. Universal cfDNA screening for Down syndrome will only become affordable by public health purchasers if costs fall substantially. Until this happens, the contingent use of cfDNA is recommended. © 2013 John Wiley & Sons, Ltd.
An ultrahigh-accuracy Miniature Dew Point Sensor based on an Integrated Photonics Platform
Tao, Jifang; Luo, Yu; Wang, Li; Cai, Hong; Sun, Tao; Song, Junfeng; Liu, Hui; Gu, Yuandong
2016-01-01
The dew point is the temperature at which vapour begins to condense out of the gaseous phase. The deterministic relationship between the dew point and humidity is the basis for the industry-standard “chilled-mirror” dew point hygrometers used for highly accurate humidity measurements, which are essential for a broad range of industrial and metrological applications. However, these instruments have several limitations, such as high cost, large size and slow response. In this report, we demonstrate a compact, integrated photonic dew point sensor (DPS) that features high accuracy, a small footprint, and fast response. The fundamental component of this DPS is a partially exposed photonic micro-ring resonator, which serves two functions simultaneously: 1) sensing the condensed water droplets via evanescent fields and 2) functioning as a highly accurate, in situ temperature sensor based on the thermo-optic effect (TOE). This device virtually eliminates most of the temperature-related errors that affect conventional “chilled-mirror” hygrometers. Moreover, this DPS outperforms conventional “chilled-mirror” hygrometers with respect to size, cost and response time, paving the way for on-chip dew point detection and extension to applications for which the conventional technology is unsuitable because of size, cost, and other constraints. PMID:27417734
Kemp, Chandler E; Ravikumar, Arvind P; Brandt, Adam R
2016-04-19
We present a tool for modeling the performance of methane leak detection and repair programs that can be used to evaluate the effectiveness of detection technologies and proposed mitigation policies. The tool uses a two-state Markov model to simulate the evolution of methane leakage from an artificial natural gas field. Leaks are created stochastically, drawing from the current understanding of the frequency and size distributions at production facilities. Various leak detection and repair programs can be simulated to determine the rate at which each would identify and repair leaks. Integrating the methane leakage over time enables a meaningful comparison between technologies, using both economic and environmental metrics. We simulate four existing or proposed detection technologies: flame ionization detection, manual infrared camera, automated infrared drone, and distributed detectors. Comparing these four technologies, we found that over 80% of simulated leakage could be mitigated with a positive net present value, although the maximum benefit is realized by selectively targeting larger leaks. Our results show that low-cost leak detection programs can rely on high-cost technology, as long as it is applied in a way that allows for rapid detection of large leaks. Any strategy to reduce leakage should require a careful consideration of the differences between low-cost technologies and low-cost programs.
Network Community Detection based on the Physarum-inspired Computational Framework.
Gao, Chao; Liang, Mingxin; Li, Xianghua; Zhang, Zili; Wang, Zhen; Zhou, Zhili
2016-12-13
Community detection is a crucial and essential problem in the structure analytics of complex networks, which can help us understand and predict the characteristics and functions of complex networks. Many methods, ranging from the optimization-based algorithms to the heuristic-based algorithms, have been proposed for solving such a problem. Due to the inherent complexity of identifying network structure, how to design an effective algorithm with a higher accuracy and a lower computational cost still remains an open problem. Inspired by the computational capability and positive feedback mechanism in the wake of foraging process of Physarum, which is a large amoeba-like cell consisting of a dendritic network of tube-like pseudopodia, a general Physarum-based computational framework for community detection is proposed in this paper. Based on the proposed framework, the inter-community edges can be identified from the intra-community edges in a network and the positive feedback of solving process in an algorithm can be further enhanced, which are used to improve the efficiency of original optimization-based and heuristic-based community detection algorithms, respectively. Some typical algorithms (e.g., genetic algorithm, ant colony optimization algorithm, and Markov clustering algorithm) and real-world datasets have been used to estimate the efficiency of our proposed computational framework. Experiments show that the algorithms optimized by Physarum-inspired computational framework perform better than the original ones, in terms of accuracy and computational cost. Moreover, a computational complexity analysis verifies the scalability of our framework.
Kick Detection at the Bit: Early Detection via Low Cost Monitoring
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tost, Brian; Rose, Kelly; Aminzadeh, Fred
2016-06-07
Formation fluid influxes (i.e. kicks) pose persistent challenges and operational costs during drilling operations. Implications of kicks range in scale but cumulatively result in substantial costs that affect drilling safety, environment, schedule, and infrastructure. Early kick detection presents a low-cost, easily adopted solution for avoiding well control challenges associated with kicks near the bit. Borehole geophysical tools used during the drilling process as part of the logging-while-drilling (LWD) and measurement-while-drilling (MWD) provide the advantage of offering real-time downhole data. LWD/MWD collect data on both the annulus and borehole wall. The annular data are normally treated as background, and are filteredmore » out to isolate the formation measurements. Because kicks will change the local physical properties of annular fluids, bottom-hole measurements are among the first indicators that a formation fluid has invaded the wellbore. This report describes and validates a technique for using the annular portion of LWD/MWD data to facilitate early kick detection using first order principles. The detection technique leverages data from standard and cost-effective technologies that are typically implemented during well drilling, such as MWD/LWD data in combination with mud-pulse telemetry for data transmission.« less
Classe, J. M.; Baffert, S.; Sigal-Zafrani, B.; Fall, M.; Rousseau, C.; Alran, S.; Rouanet, P.; Belichard, C.; Mignotte, H.; Ferron, G.; Marchal, F.; Giard, S.; Tunon de Lara, C.; Le Bouedec, G.; Cuisenier, J.; Werner, R.; Raoust, I.; Rodier, J.-F.; Laki, F.; Colombo, P.-E.; Lasry, S.; Faure, C.; Charitansky, H.; Olivier, J.-B.; Chauvet, M.-P.; Bussières, E.; Gimbergues, P.; Flipo, B.; Houvenaeghel, G.; Dravet, F.; Livartowski, A.
2012-01-01
Background: Our objective was to assess the global cost of the sentinel lymph node detection [axillary sentinel lymph node detection (ASLND)] compared with standard axillary lymphadenectomy [axillary lymph node dissection (ALND)] for early breast cancer patients. Patients and methods: We conducted a prospective, multi-institutional, observational, cost comparative analysis. Cost calculations were realized with the micro-costing method from the diagnosis until 1 month after the last surgery. Results: Eight hundred and thirty nine patients were included in the ASLND group and 146 in the ALND group. The cost generated for a patient with an ASLND, with one preoperative scintigraphy, a combined method for sentinel node detection, an intraoperative pathological analysis without lymphadenectomy, was lower than the cost generated for a patient with lymphadenectomy [€2947 (σ = 580) versus €3331 (σ = 902); P = 0.0001]. Conclusion: ASLND, involving expensive techniques, was finally less expensive than ALND. The length of hospital stay was the cost driver of these procedures. The current observational study points the heterogeneous practices for this validated and largely diffused technique. Several technical choices have an impact on the cost of ASLND, as intraoperative analysis allowing to reduce rehospitalization rate for secondary lymphadenectomy or preoperative scintigraphy, suggesting possible savings on hospital resources. PMID:21896543
NASA Technical Reports Server (NTRS)
Koehne, Jessica E.; Chen, Hua; Cassell, Alan M.; Ye, Qi; Han, Jie; Meyyappan, Meyya; Li, Jun
2004-01-01
BACKGROUND: Reducing cost and time is the major concern in clinical diagnostics, particularly in molecular diagnostics. Miniaturization technologies have been recognized as promising solutions to provide low-cost microchips for diagnostics. With the recent advancement in nanotechnologies, it is possible to further improve detection sensitivity and simplify sample preparation by incorporating nanoscale elements in diagnostics devices. A fusion of micro- and nanotechnologies with biology has great potential for the development of low-cost disposable chips for rapid molecular analysis that can be carried out with simple handheld devices. APPROACH: Vertically aligned multiwalled carbon nanotubes (MWNTs) are fabricated on predeposited microelectrode pads and encapsulated in SiO2 dielectrics with only the very end exposed at the surface to form an inlaid nanoelectrode array (NEA). The NEA is used to collect the electrochemical signal associated with the target molecules binding to the probe molecules, which are covalently attached to the end of the MWNTs. CONTENT: A 3 x 3 microelectrode array is presented to demonstrate the miniaturization and multiplexing capability. A randomly distributed MWNT NEA is fabricated on each microelectrode pad. Selective functionalization of the MWNT end with a specific oligonucleotide probe and passivation of the SiO2 surface with ethylene glycol moieties are discussed. Ru(bpy)2+ -mediator-amplified guanine oxidation is used to directly measure the electrochemical signal associated with target molecules. SUMMARY: The discussed MWNT NEAs have ultrahigh sensitivity in direct electrochemical detection of guanine bases in the nucleic acid target. Fewer than approximately 1000 target nucleic acid molecules can be measured with a single microelectrode pad of approximately 20 x 20 microm2, which approaches the detection limit of laser scanners in fluorescence-based DNA microarray techniques. MWNT NEAs can be easily integrated with microelectronic circuitry and microfluidics for development of a fully automated system for rapid molecular analysis with minimum cost.
NASA Astrophysics Data System (ADS)
Zargarzadeh, H.; Nodland, David; Thotla, V.; Jagannathan, S.; Agarwal, S.
2012-06-01
Unmanned Aerial Vehicles (UAVs) are versatile aircraft with many applications, including the potential for use to detect unintended electromagnetic emissions from electronic devices. A particular area of recent interest has been helicopter unmanned aerial vehicles. Because of the nature of these helicopters' dynamics, high-performance controller design for them presents a challenge. This paper introduces an optimal controller design via output feedback control for trajectory tracking of a helicopter UAV using a neural network (NN). The output-feedback control system utilizes the backstepping methodology, employing kinematic, virtual, and dynamic controllers and an observer. Optimal tracking is accomplished with a single NN utilized for cost function approximation. The controller positions the helicopter, which is equipped with an antenna, such that the antenna can detect unintended emissions. The overall closed-loop system stability with the proposed controller is demonstrated by using Lyapunov analysis. Finally, results are provided to demonstrate the effectiveness of the proposed control design for positioning the helicopter for unintended emissions detection.
Lin, Tzu-Hsuan; Lu, Yung-Chi; Hung, Shih-Lin
2014-01-01
This study developed an integrated global-local approach for locating damage on building structures. A damage detection approach with a novel embedded frequency response function damage index (NEFDI) was proposed and embedded in the Imote2.NET-based wireless structural health monitoring (SHM) system to locate global damage. Local damage is then identified using an electromechanical impedance- (EMI-) based damage detection method. The electromechanical impedance was measured using a single-chip impedance measurement device which has the advantages of small size, low cost, and portability. The feasibility of the proposed damage detection scheme was studied with reference to a numerical example of a six-storey shear plane frame structure and a small-scale experimental steel frame. Numerical and experimental analysis using the integrated global-local SHM approach reveals that, after NEFDI indicates the approximate location of a damaged area, the EMI-based damage detection approach can then identify the detailed damage location in the structure of the building.
Spacecube: A Family of Reconfigurable Hybrid On-Board Science Data Processors
NASA Technical Reports Server (NTRS)
Flatley, Thomas P.
2015-01-01
SpaceCube is a family of Field Programmable Gate Array (FPGA) based on-board science data processing systems developed at the NASA Goddard Space Flight Center (GSFC). The goal of the SpaceCube program is to provide 10x to 100x improvements in on-board computing power while lowering relative power consumption and cost. SpaceCube is based on the Xilinx Virtex family of FPGAs, which include processor, FPGA logic and digital signal processing (DSP) resources. These processing elements are leveraged to produce a hybrid science data processing platform that accelerates the execution of algorithms by distributing computational functions to the most suitable elements. This approach enables the implementation of complex on-board functions that were previously limited to ground based systems, such as on-board product generation, data reduction, calibration, classification, eventfeature detection, data mining and real-time autonomous operations. The system is fully reconfigurable in flight, including data parameters, software and FPGA logic, through either ground commanding or autonomously in response to detected eventsfeatures in the instrument data stream.
NASA Astrophysics Data System (ADS)
Noriani, C.; Hashim, U.; Azizah, N.; Nadzirah, Sh.; Arshad, M. K. Md; Ruslinda, A. R.; Gopinath, Subash C. B.
2017-03-01
Human Papillomaviruses (HPV) is the major cause of cervical cancer. HPV 16 and HPV 18 are the two types of HPV are the most HPV-associated cancers and responsible as a high-risk HPV. Cervical cancer took about 70 percent of all cases due to HPV infections. Cervical cancer mostly growth on a woman's cervix and its was developed slowly as cancer. TiO2 particles give better performance and low cost of the biosensor. The used of 3-aminopropyl triethoxysilane (APTES) will be more efficient for DNA nanochip. APTES used as absorption reaction to immobilize organic biomolecules on the inorganic surface. Furthermore, APTES provide better functionalization of the adsorption mechanism on IDE. The surface functionalized for immobilizing the DNA, which is the combination of the DNA probe and the HPV target produces high sensitivity and speed detection of the IDE. The Current-Voltage (IV) characteristic proved the sensitivity of the DNA nanochip increase as the concentration varied from 0% concentration to 24% of APTES concentration.
Tire Force Estimation using a Proportional Integral Observer
NASA Astrophysics Data System (ADS)
Farhat, Ahmad; Koenig, Damien; Hernandez-Alcantara, Diana; Morales-Menendez, Ruben
2017-01-01
This paper addresses a method for detecting critical stability situations in the lateral vehicle dynamics by estimating the non-linear part of the tire forces. These forces indicate the road holding performance of the vehicle. The estimation method is based on a robust fault detection and estimation approach which minimize the disturbance and uncertainties to residual sensitivity. It consists in the design of a Proportional Integral Observer (PIO), while minimizing the well known H ∞ norm for the worst case uncertainties and disturbance attenuation, and combining a transient response specification. This multi-objective problem is formulated as a Linear Matrix Inequalities (LMI) feasibility problem where a cost function subject to LMI constraints is minimized. This approach is employed to generate a set of switched robust observers for uncertain switched systems, where the convergence of the observer is ensured using a Multiple Lyapunov Function (MLF). Whilst the forces to be estimated can not be physically measured, a simulation scenario with CarSimTM is presented to illustrate the developed method.
Goldberg, Caren S.; Sepulveda, Adam; Ray, Andrew; Baumgardt, Jeremy A.; Waits, Lisette P.
2013-01-01
Early detection of aquatic invasive species is a critical task for management of aquatic ecosystems. This task is hindered by the difficulty and cost of surveying aquatic systems thoroughly. The New Zealand mudsnail (Potamopyrgus antipodarum) is a small, invasive parthenogenic mollusk that can reach very high population densities and severely affects ecosystem functioning. To assist in the early detection of this invasive species, we developed and validated a highly sensitive environmental deoxyribonucleic acid (eDNA) assay. We used a dose–response laboratory experiment to investigate the relationship between New Zealand mudsnail density and eDNA detected through time. We documented that as few as 1 individual in 1.5 L of water for 2 d could be detected with this method, and that eDNA from this species may remain detectable for 21 to 44 d after mudsnail removal. We used the eDNA method to confirm the presence of New Zealand mudsnail eDNA at densities as low as 11 to 144 snails/m2 in a eutrophic 5th-order river. Combined, these results demonstrate the high potential for eDNA surveys to assist with early detection of a widely distributed invasive aquatic invertebrate.
DHPLC technology for high-throughput detection of mutations in a durum wheat TILLING population.
Colasuonno, Pasqualina; Incerti, Ornella; Lozito, Maria Luisa; Simeone, Rosanna; Gadaleta, Agata; Blanco, Antonio
2016-02-17
Durum wheat (Triticum turgidum L.) is a cereal crop widely grown in the Mediterranean regions; the amber grain is mainly used for the production of pasta, couscous and typical breads. Single nucleotide polymorphism (SNP) detection technologies and high-throughput mutation induction represent a new challenge in wheat breeding to identify allelic variation in large populations. The TILLING strategy makes use of traditional chemical mutagenesis followed by screening for single base mismatches to identify novel mutant loci. Although TILLING has been combined to several sensitive pre-screening methods for SNP analysis, most rely on expensive equipment. Recently, a new low cost and time saving DHPLC protocol has been used in molecular human diagnostic to detect unknown mutations. In this work, we developed a new durum wheat TILLING population (cv. Marco Aurelio) using 0.70-0.85% ethyl methane sulfonate (EMS). To investigate the efficiency of the mutagenic treatments, a pilot screening was carried out on 1,140 mutant lines focusing on two target genes (Lycopene epsilon-cyclase, ε-LCY, and Lycopene beta-cyclase, β-LCY) involved in carotenoid metabolism in wheat grains. We simplify the heteroduplex detection by two low cost methods: the enzymatic cleavage (CelI)/agarose gel technique and the denaturing high-performance liquid chromatography (DHPLC). The CelI/agarose gel approach allowed us to identify 31 mutations, whereas the DHPLC procedure detected a total of 46 mutations for both genes. All detected mutations were confirmed by direct sequencing. The estimated overall mutation frequency for the pilot assay by the DHPLC methodology resulted to be of 1/77 kb, representing a high probability to detect interesting mutations in the target genes. We demonstrated the applicability and efficiency of a new strategy for the detection of induced variability. We produced and characterized a new durum wheat TILLING population useful for a better understanding of key gene functions. The availability of this tool together with TILLING technique will expand the polymorphisms in candidate genes of agronomically important traits in wheat.
What Do Cost Functions Tell Us about the Cost of an Adequate Education?
ERIC Educational Resources Information Center
Costrell, Robert M.; Hanushek, Eric; Loeb, Susanna
2008-01-01
Econometric cost functions have begun to appear in education adequacy cases with greater frequency. Cost functions are superficially attractive because they give the impression of objectivity, holding out the promise of scientifically estimating the cost of achieving specified levels of performance from actual data on spending. By contrast, the…
Low-cost coherent receiver for long-reach optical access network using single-ended detection.
Zhang, Xuebing; Li, Zhaohui; Li, Jianping; Yu, Changyuan; Lau, Alan Pak Tao; Lu, Chao
2014-09-15
A low-cost coherent receiver using two 2×3 optical hybrids and single-ended detection is proposed for long-reach optical access network. This structure can detect the two polarization components of polarization division multiplexing (PDM) signals. Polarization de-multiplexing and signal-to-signal beat interference (SSBI) cancellation are realized by using only three photodiodes. Simulation results for 40 Gb/s PDM-OFDM transmissions indicate that the low-cost coherent receiver has 3.2 dB optical signal-to-noise ratio difference compared with the theoretical value.
An optrode for photometric detection of ammonia in air
NASA Astrophysics Data System (ADS)
Buzanovskii, V. A.
2017-10-01
A scheme of constructing an LED optrode for photometric detection of ammonia in air is considered. The components of the device are (1) a glass plate coated with a film of polydimethylsiloxane with an ion-coupled cation of brilliant-green dye, (2) an LED emitting at a wavelength of 655 nm, and (3) a metal housing. The nominal static conversion function, sensitivity, and relative measurement error of the device are analyzed on the basis of mathematical modeling. The obtained results allow one to design an LED optrode capable of carrying out control for automated technological processes, solving problems in the area of security, etc. The device provides the ability to create photometric gas analyzers of ammonia with small overall dimensions, power consumption, and cost.
NASA Astrophysics Data System (ADS)
Mahl, Adam; Yemam, Henok; Remedes, Tyler; Stuntz, Jack; Koldemir, Unsal; Sellinger, Alan; Greife, Uwe
2015-10-01
This presentation will review the efforts made by an interdisciplinary development project aimed at cost-effective, thermal neutron sensitive, plastic scintillators as part of the communities efforts towards replacing 3He based detectors. Colorado School of Mines researchers with backgrounds in Physics and Chemistry have worked on the incorporation of 10B in plastics through admixture of various commercial and novel dopants developed at CSM. In addition, new fluorescent dopants have been developed for plastic scintillators in an effort towards better understanding quenching effects and scintillator response to thermal neutrons via pulse shape discrimination methods. Results on transparent samples using fluorescent spectroscopy and gamma/neutron excitation will be presented. Funded via Department of Homeland Security - Domestic Nuclear Detection Office.
Metamaterial split ring resonator as a sensitive mechanical vibration sensor
NASA Astrophysics Data System (ADS)
Sikha Simon, K.; Chakyar, Sreedevi P.; Andrews, Jolly; Joseph V., P.
2017-06-01
This paper introduces a sensitive vibration sensor based on microwave metamaterial Split Ring Resonator (SRR) capable of detecting any ground vibration. The experimental setup consists of single Broad-side Coupled SRR (BCSRR) unit fixed on a cantilever capable of sensitive vibrations. It is arranged between transmitting and receiving probes of a microwave measurement system. The absorption level variations at the resonant frequency due to the displacement from the reference plane of SRR, which is a function of the strength of external mechanical vibration, is analyzed. This portable and cost effective sensor working on a single frequency is observed to be capable of detecting even very weak vibrations. This may find potential applications in the field of tamper-proofing, mining, quarrying and earthquake sensing.
Measurement, time-stamping, and analysis of electrodermal activity in fMRI
NASA Astrophysics Data System (ADS)
Smyser, Christopher; Grabowski, Thomas J.; Rainville, Pierre; Bechara, Antione; Razavi, Mehrdad; Mehta, Sonya; Eaton, Brent L.; Bolinger, Lizann
2002-04-01
A low cost fMRI-compatible system was developed for detecting electrodermal activity without inducing image artifact. Subject electrodermal activity was measured on the plantar surface of the foot using a standard recording circuit. Filtered analog skin conductance responses (SCR) were recorded with a general purpose, time-stamping data acquisition system. A conditioning paradigm involving painful thermal stimulation was used to demonstrate SCR detection and investigate neural correlates of conditioned autonomic activity. 128x128 pixel EPI-BOLD images were acquired with a GE 1.5T Signa scanner. Image analysis was performed using voxel-wise multiple linear regression. The covariate of interest was generated by convolving stimulus event onset with a standard hemodynamic response function. The function was time-shifted to determine optimal activation. Significance was tested using the t-statistic. Image quality was unaffected by the device, and conditioned and unconditioned SCRs were successfully detected. Conditioned SCRs correlated significantly with activity in the right anterior insular cortex. The effect was more robust when responses were scaled by SCR amplitude. The ability to measure and time register SCRs during fMRI acquisition enables studies of cognitive processes marked by autonomic activity, including those involving decision-making, pain, emotion, and addiction.
A Precise Drunk Driving Detection Using Weighted Kernel Based on Electrocardiogram.
Wu, Chung Kit; Tsang, Kim Fung; Chi, Hao Ran; Hung, Faan Hei
2016-05-09
Globally, 1.2 million people die and 50 million people are injured annually due to traffic accidents. These traffic accidents cost $500 billion dollars. Drunk drivers are found in 40% of the traffic crashes. Existing drunk driving detection (DDD) systems do not provide accurate detection and pre-warning concurrently. Electrocardiogram (ECG) is a proven biosignal that accurately and simultaneously reflects human's biological status. In this letter, a classifier for DDD based on ECG is investigated in an attempt to reduce traffic accidents caused by drunk drivers. At this point, it appears that there is no known research or literature found on ECG classifier for DDD. To identify drunk syndromes, the ECG signals from drunk drivers are studied and analyzed. As such, a precise ECG-based DDD (ECG-DDD) using a weighted kernel is developed. From the measurements, 10 key features of ECG signals were identified. To incorporate the important features, the feature vectors are weighted in the customization of kernel functions. Four commonly adopted kernel functions are studied. Results reveal that weighted feature vectors improve the accuracy by 11% compared to the computation using the prime kernel. Evaluation shows that ECG-DDD improved the accuracy by 8% to 18% compared to prevailing methods.
Merlos Rodrigo, Miguel Angel; Krejcova, Ludmila; Kudr, Jiri; Cernei, Natalia; Kopel, Pavel; Richtera, Lukas; Moulick, Amitava; Hynek, David; Adam, Vojtech; Stiborova, Marie; Eckschlager, Tomas; Heger, Zbynek; Zitka, Ondrej
2016-12-15
Metallothioneins (MTs) are involved in heavy metal detoxification in a wide range of living organisms. Currently, it is well known that MTs play substantial role in many pathophysiological processes, including carcinogenesis, and they can serve as diagnostic biomarkers. In order to increase the applicability of MT in cancer diagnostics, an easy-to-use and rapid method for its detection is required. Hence, the aim of this study was to develop a fully automated and high-throughput assay for the estimation of MT levels. Here, we report the optimal conditions for the isolation of MTs from rabbit liver and their characterization using MALDI-TOF MS. In addition, we described a two-step assay, which started with an isolation of the protein using functionalized paramagnetic particles and finished with their electrochemical analysis. The designed easy-to-use, cost-effective, error-free and fully automated procedure for the isolation of MT coupled with a simple analytical detection method can provide a prototype for the construction of a diagnostic instrument, which would be appropriate for the monitoring of carcinogenesis or MT-related chemoresistance of tumors. Copyright © 2016 Elsevier B.V. All rights reserved.
Herscovici, Sarah; Pe'er, Avivit; Papyan, Surik; Lavie, Peretz
2007-02-01
Scoring of REM sleep based on polysomnographic recordings is a laborious and time-consuming process. The growing number of ambulatory devices designed for cost-effective home-based diagnostic sleep recordings necessitates the development of a reliable automatic REM sleep detection algorithm that is not based on the traditional electroencephalographic, electrooccolographic and electromyographic recordings trio. This paper presents an automatic REM detection algorithm based on the peripheral arterial tone (PAT) signal and actigraphy which are recorded with an ambulatory wrist-worn device (Watch-PAT100). The PAT signal is a measure of the pulsatile volume changes at the finger tip reflecting sympathetic tone variations. The algorithm was developed using a training set of 30 patients recorded simultaneously with polysomnography and Watch-PAT100. Sleep records were divided into 5 min intervals and two time series were constructed from the PAT amplitudes and PAT-derived inter-pulse periods in each interval. A prediction function based on 16 features extracted from the above time series that determines the likelihood of detecting a REM epoch was developed. The coefficients of the prediction function were determined using a genetic algorithm (GA) optimizing process tuned to maximize a price function depending on the sensitivity, specificity and agreement of the algorithm in comparison with the gold standard of polysomnographic manual scoring. Based on a separate validation set of 30 patients overall sensitivity, specificity and agreement of the automatic algorithm to identify standard 30 s epochs of REM sleep were 78%, 92%, 89%, respectively. Deploying this REM detection algorithm in a wrist worn device could be very useful for unattended ambulatory sleep monitoring. The innovative method of optimization using a genetic algorithm has been proven to yield robust results in the validation set.
An intelligent artificial throat with sound-sensing ability based on laser induced graphene
Tao, Lu-Qi; Tian, He; Liu, Ying; Ju, Zhen-Yi; Pang, Yu; Chen, Yuan-Quan; Wang, Dan-Yang; Tian, Xiang-Guang; Yan, Jun-Chao; Deng, Ning-Qin; Yang, Yi; Ren, Tian-Ling
2017-01-01
Traditional sound sources and sound detectors are usually independent and discrete in the human hearing range. To minimize the device size and integrate it with wearable electronics, there is an urgent requirement of realizing the functional integration of generating and detecting sound in a single device. Here we show an intelligent laser-induced graphene artificial throat, which can not only generate sound but also detect sound in a single device. More importantly, the intelligent artificial throat will significantly assist for the disabled, because the simple throat vibrations such as hum, cough and scream with different intensity or frequency from a mute person can be detected and converted into controllable sounds. Furthermore, the laser-induced graphene artificial throat has the advantage of one-step fabrication, high efficiency, excellent flexibility and low cost, and it will open practical applications in voice control, wearable electronics and many other areas. PMID:28232739
An intelligent artificial throat with sound-sensing ability based on laser induced graphene.
Tao, Lu-Qi; Tian, He; Liu, Ying; Ju, Zhen-Yi; Pang, Yu; Chen, Yuan-Quan; Wang, Dan-Yang; Tian, Xiang-Guang; Yan, Jun-Chao; Deng, Ning-Qin; Yang, Yi; Ren, Tian-Ling
2017-02-24
Traditional sound sources and sound detectors are usually independent and discrete in the human hearing range. To minimize the device size and integrate it with wearable electronics, there is an urgent requirement of realizing the functional integration of generating and detecting sound in a single device. Here we show an intelligent laser-induced graphene artificial throat, which can not only generate sound but also detect sound in a single device. More importantly, the intelligent artificial throat will significantly assist for the disabled, because the simple throat vibrations such as hum, cough and scream with different intensity or frequency from a mute person can be detected and converted into controllable sounds. Furthermore, the laser-induced graphene artificial throat has the advantage of one-step fabrication, high efficiency, excellent flexibility and low cost, and it will open practical applications in voice control, wearable electronics and many other areas.
Development of the infrared instrument for gas detection
NASA Astrophysics Data System (ADS)
Chen, Ching-Wei; Chen, Chia-Ray
2017-08-01
MWIR (Mid-Wave Infrared) spectroscopy shows a large potential in the current IR devices market, due to its multiple applications, such as gas detection, chemical analysis, industrial monitoring, combustion and flame characterization. It opens this technique to the fields of application, such as industrial monitoring and control, agriculture and environmental monitoring. However, a major barrier, which is the lack of affordable specific key elements such a MWIR light sources and low cost uncooled detectors, have held it back from its widespread use. In this paper an uncooled MWIR detector combined with image enhancement technique is reported. This investigation shows good results in gas leakage detection test. It also verify the functions of self-developed MWIR lens and optics. A good agreement in theoretical design and experiment give us the lessons learned for the potential application in infrared satellite technology. A brief discussions will also be presented in this paper.
3D Printing and Assay Development for Point-of-Care Applications
NASA Astrophysics Data System (ADS)
Jagadeesh, Shreesha
Existing centralized labs do not serve patients adequately in remote areas. To enable universal timely healthcare, there is a need to develop low cost, portable systems that can diagnose multiple disease (Point-of-Care (POC) devices). Future POC diagnostics can be more multi-functional if medical device vendors can develop interoperability standards. This thesis developed the following medical diagnostic modules: Plasma from 25 microl blood was extracted through a filter membrane to demonstrate a 3D printed sample preparation module. Sepsis biomarker, C - reactive protein, was quantified through adsorption on nylon beads to demonstrate bead-based assay suitable for 3D printed disposable cartridge module. Finally, a modular fluorescent detection kit was built using 3D printed parts to detect CD4 cells in a disposable cartridge from ChipCare Corp. Due to the modularity enabled by 3D printing technique, the developed units can be easily adapted to detect other diseases.
Tehrani, Farshad; Bavarian, Behzad
2016-01-01
A novel and highly sensitive disposable glucose sensor strip was developed using direct laser engraved graphene (DLEG) decorated with pulse deposited copper nanocubes (CuNCs). The high reproducibility (96.8%), stability (97.4%) and low cost demonstrated by this 3-step fabrication method indicates that it could be used for high volume manufacturing of disposable glucose strips. The fabrication method also allows for a high degree of flexibility, allowing for control of the electrode size, design, and functionalization method. Additionally, the excellent selectivity and sensitivity (4,532.2 μA/mM.cm2), low detection limit (250 nM), and suitable linear range of 25 μM–4 mM, suggests that these sensors may be a great potential platform for glucose detection within the physiological range for tear, saliva, and/or sweat. PMID:27306706
Multi person detection and tracking based on hierarchical level-set method
NASA Astrophysics Data System (ADS)
Khraief, Chadia; Benzarti, Faouzi; Amiri, Hamid
2018-04-01
In this paper, we propose an efficient unsupervised method for mutli-person tracking based on hierarchical level-set approach. The proposed method uses both edge and region information in order to effectively detect objects. The persons are tracked on each frame of the sequence by minimizing an energy functional that combines color, texture and shape information. These features are enrolled in covariance matrix as region descriptor. The present method is fully automated without the need to manually specify the initial contour of Level-set. It is based on combined person detection and background subtraction methods. The edge-based is employed to maintain a stable evolution, guide the segmentation towards apparent boundaries and inhibit regions fusion. The computational cost of level-set is reduced by using narrow band technique. Many experimental results are performed on challenging video sequences and show the effectiveness of the proposed method.
An intelligent artificial throat with sound-sensing ability based on laser induced graphene
NASA Astrophysics Data System (ADS)
Tao, Lu-Qi; Tian, He; Liu, Ying; Ju, Zhen-Yi; Pang, Yu; Chen, Yuan-Quan; Wang, Dan-Yang; Tian, Xiang-Guang; Yan, Jun-Chao; Deng, Ning-Qin; Yang, Yi; Ren, Tian-Ling
2017-02-01
Traditional sound sources and sound detectors are usually independent and discrete in the human hearing range. To minimize the device size and integrate it with wearable electronics, there is an urgent requirement of realizing the functional integration of generating and detecting sound in a single device. Here we show an intelligent laser-induced graphene artificial throat, which can not only generate sound but also detect sound in a single device. More importantly, the intelligent artificial throat will significantly assist for the disabled, because the simple throat vibrations such as hum, cough and scream with different intensity or frequency from a mute person can be detected and converted into controllable sounds. Furthermore, the laser-induced graphene artificial throat has the advantage of one-step fabrication, high efficiency, excellent flexibility and low cost, and it will open practical applications in voice control, wearable electronics and many other areas.
Orthology detection combining clustering and synteny for very large datasets.
Lechner, Marcus; Hernandez-Rosales, Maribel; Doerr, Daniel; Wieseke, Nicolas; Thévenin, Annelyse; Stoye, Jens; Hartmann, Roland K; Prohaska, Sonja J; Stadler, Peter F
2014-01-01
The elucidation of orthology relationships is an important step both in gene function prediction as well as towards understanding patterns of sequence evolution. Orthology assignments are usually derived directly from sequence similarities for large data because more exact approaches exhibit too high computational costs. Here we present PoFF, an extension for the standalone tool Proteinortho, which enhances orthology detection by combining clustering, sequence similarity, and synteny. In the course of this work, FFAdj-MCS, a heuristic that assesses pairwise gene order using adjacencies (a similarity measure related to the breakpoint distance) was adapted to support multiple linear chromosomes and extended to detect duplicated regions. PoFF largely reduces the number of false positives and enables more fine-grained predictions than purely similarity-based approaches. The extension maintains the low memory requirements and the efficient concurrency options of its basis Proteinortho, making the software applicable to very large datasets.
Orthology Detection Combining Clustering and Synteny for Very Large Datasets
Lechner, Marcus; Hernandez-Rosales, Maribel; Doerr, Daniel; Wieseke, Nicolas; Thévenin, Annelyse; Stoye, Jens; Hartmann, Roland K.; Prohaska, Sonja J.; Stadler, Peter F.
2014-01-01
The elucidation of orthology relationships is an important step both in gene function prediction as well as towards understanding patterns of sequence evolution. Orthology assignments are usually derived directly from sequence similarities for large data because more exact approaches exhibit too high computational costs. Here we present PoFF, an extension for the standalone tool Proteinortho, which enhances orthology detection by combining clustering, sequence similarity, and synteny. In the course of this work, FFAdj-MCS, a heuristic that assesses pairwise gene order using adjacencies (a similarity measure related to the breakpoint distance) was adapted to support multiple linear chromosomes and extended to detect duplicated regions. PoFF largely reduces the number of false positives and enables more fine-grained predictions than purely similarity-based approaches. The extension maintains the low memory requirements and the efficient concurrency options of its basis Proteinortho, making the software applicable to very large datasets. PMID:25137074
NASA Astrophysics Data System (ADS)
Tehrani, Farshad; Bavarian, Behzad
2016-06-01
A novel and highly sensitive disposable glucose sensor strip was developed using direct laser engraved graphene (DLEG) decorated with pulse deposited copper nanocubes (CuNCs). The high reproducibility (96.8%), stability (97.4%) and low cost demonstrated by this 3-step fabrication method indicates that it could be used for high volume manufacturing of disposable glucose strips. The fabrication method also allows for a high degree of flexibility, allowing for control of the electrode size, design, and functionalization method. Additionally, the excellent selectivity and sensitivity (4,532.2 μA/mM.cm2), low detection limit (250 nM), and suitable linear range of 25 μM-4 mM, suggests that these sensors may be a great potential platform for glucose detection within the physiological range for tear, saliva, and/or sweat.
DNA hybridization sensor based on pentacene thin film transistor.
Kim, Jung-Min; Jha, Sandeep Kumar; Chand, Rohit; Lee, Dong-Hoon; Kim, Yong-Sang
2011-01-15
A DNA hybridization sensor using pentacene thin film transistors (TFTs) is an excellent candidate for disposable sensor applications due to their low-cost fabrication process and fast detection. We fabricated pentacene TFTs on glass substrate for the sensing of DNA hybridization. The ss-DNA (polyA/polyT) or ds-DNA (polyA/polyT hybrid) were immobilized directly on the surface of the pentacene, producing a dramatic change in the electrical properties of the devices. The electrical characteristics of devices were studied as a function of DNA immobilization, single-stranded vs. double-stranded DNA, DNA length and concentration. The TFT device was further tested for detection of λ-phage genomic DNA using probe hybridization. Based on these results, we propose that a "label-free" detection technique for DNA hybridization is possible through direct measurement of electrical properties of DNA-immobilized pentacene TFTs. Copyright © 2010 Elsevier B.V. All rights reserved.
Thakur, Js; Prinja, Shankar; Jeet, Gursimer; Bhatnagar, Nidhi
2016-01-01
Punjab state is particularly reporting a rising burden of cancer. A 'door to door cancer awareness and early detection campaign' was therefore launched in the Punjab covering about 2.67 million population, wherein after initial training accredited social health activists (ASHAs) and other health staff conducted a survey for early detection of cancer cases based on a twelve point clinical algorithm. To ascertain unit cost for undertaking a population-based cancer awareness and early detection campaign. Data were collected using bottom-up costing methods. Full economic costs of implementing the campaign from the health system perspective were calculated. Options to meet the likely demand for project activities were further evaluated to examine their worth from the point of view of long-term sustainability. The campaign covered 97% of the state population. A total of 24,659 cases were suspected to have cancer and were referred to health facilities. At the state level, incidence and prevalence of cancer were found to be 90 and 216 per 100,000, respectively. Full economic cost of implementing the campaign in pilot district was USD 117,524. However, the financial cost was approximately USD 6,301. Start-up phase of campaign was more resource intensive (63% of total) than the implementation phase. The economic cost per person contacted and suspected by clinical algorithm was found to be USD 0.20 and USD 40 respectively. Cost per confirmed case under the campaign was 7,043 USD. The campaign was able to screen a reasonably large population. High to high economic cost points towards the fact that the opportunity cost of campaign put a significant burden on health system and other programs. However, generating awareness and early detection strategy adopted in this campaign seems promising in light of fact that organized screening is not in place in India and in many developing countries.
Cai, Shan-Rong; Zhu, Hong-Hong; Huang, Yan-Qin; Li, Qi-Long; Ma, Xin-Yuan; Zhang, Su-Zhan; Zheng, Shu
2016-01-01
This study investigated the cost-effectiveness between double and single Fecal Immunochemical Test(s) (FIT) in a mass CRC screening. A two-stage sequential screening was conducted. FIT was used as a primary screening test and recommended twice by an interval of one week at the first screening stage. We defined the first-time FIT as FIT1 and the second-time FIT as FIT2. If either FIT1 or FIT2 was positive (+), then a colonoscopy was recommended at the second stage. Costs were recorded and analyzed. A total of 24,419 participants completed either FIT1 or FIT2. The detection rate of advanced neoplasm was 19.2% among both FIT1+ and FIT2+, especially high among men with age ≥55 (27.4%). About 15.4% CRC, 18.9% advanced neoplasm, and 29.9% adenoma missed by FIT1 were detected by FIT2 alone. Average cost was $2,935 for double FITs and $2,121 for FIT1 to detect each CRC and $901 for double FITs and $680 for FIT1 to detect each advanced neoplasm. Double FITs are overall more cost-effective, having significantly higher positive and detection rates with an acceptable higher cost, than single FIT. Double FITs should be encouraged for the first screening in a mass CRC screening, especially in economically and medically underserved populations/areas/countries.
Cost-benefit analysis: newborn screening for inborn errors of metabolism in Lebanon.
Khneisser, I; Adib, S; Assaad, S; Megarbane, A; Karam, P
2015-12-01
Few countries in the Middle East-North Africa region have adopted national newborn screening for inborn errors of metabolism by tandem mass spectrometry (MS/MS). We aimed to evaluate the cost-benefit of newborn screening for such disorders in Lebanon, as a model for other developing countries in the region. Average costs of expected care for inborn errors of metabolism cases as a group, between ages 0 and 18, early and late diagnosed, were calculated from 2007 to 2013. The monetary value of early detection using MS/MS was compared with that of clinical "late detection", including cost of diagnosis and hospitalizations. During this period, 126000 newborns were screened. Incidence of detected cases was 1/1482, which can be explained by high consanguinity rates in Lebanon. A reduction by half of direct cost of care, reaching on average 31,631 USD per detected case was shown. This difference more than covers the expense of starting a newborn screening programme. Although this model does not take into consideration the indirect benefits of the better quality of life of those screened early, it can be argued that direct and indirect costs saved through early detection of these disorders are important enough to justify universal publicly-funded screening, especially in developing countries with high consanguinity rates, as shown through this data from Lebanon. © The Author(s) 2015.
Costs of detection bias in index-based population monitoring
Moore, C.T.; Kendall, W.L.
2004-01-01
Managers of wildlife populations commonly rely on indirect, count-based measures of the population in making decisions regarding conservation, harvest, or control. The main appeal in the use of such counts is their low material expense compared to methods that directly measure the population. However, their correct use rests on the rarely-tested but often-assumed premise that they proportionately reflect population size, i.e., that they constitute a population index. This study investigates forest management for the endangered Red-cockaded Woodpecker (Picoides borealis) and the Wood Thrush (Hylocichla mustelina) at the Piedmont National Wildlife Refuge in central Georgia, U.S.A. Optimal decision policies for a joint species objective were derived for two alternative models of Wood Thrush population dynamics. Policies were simulated under scenarios of unbiasedness, consistent negative bias, and habitat-dependent negative bias in observed Wood Thrush densities. Differences in simulation outcomes between biased and unbiased detection scenarios indicated the expected loss in resource objectives (here, forest habitat and birds) through decision-making based on biased population counts. Given the models and objective function used in our analysis, expected losses were as great as 11%, a degree of loss perhaps not trivial for applications such as endangered species management. Our analysis demonstrates that costs of uncertainty about the relationship between the population and its observation can be measured in units of the resource, costs which may offset apparent savings achieved by collecting uncorrected population counts.
Photo-Attachment of Biomolecules for Miniaturization on Wicking Si-Nanowire Platform
Cheng, He; Zheng, Han; Wu, Jia Xin; Xu, Wei; Zhou, Lihan; Leong, Kam Chew; Fitzgerald, Eugene; Rajagopalan, Raj; Too, Heng Phon; Choi, Wee Kiong
2015-01-01
We demonstrated the surface functionalization of a highly three-dimensional, superhydrophilic wicking substrate using light to immobilize functional biomolecules for sensor or microarray applications. We showed here that the three-dimensional substrate was compatible with photo-attachment and the performance of functionalization was greatly improved due to both increased surface capacity and reduced substrate reflectivity. In addition, photo-attachment circumvents the problems induced by wicking effect that was typically encountered on superhydrophilic three-dimensional substrates, thus reducing the difficulty of producing miniaturized sites on such substrate. We have investigated various aspects of photo-attachment process on the nanowire substrate, including the role of different buffers, the effect of wavelength as well as how changing probe structure may affect the functionalization process. We demonstrated that substrate fabrication and functionalization can be achieved with processes compatible with microelectronics processes, hence reducing the cost of array fabrication. Such functionalization method coupled with the high capacity surface makes the substrate an ideal candidate for sensor or microarray for sensitive detection of target analytes. PMID:25689680
Huff, Mark J.; Balota, David A.; Minear, Meredith; Aschenbrenner, Andrew J.; Duchek, Janet M.
2015-01-01
A task-switching paradigm was used to examine differences in attentional control across younger adults, middle-aged adults, healthy older adults, and individuals classified in the earliest detectable stage of Alzheimer's disease (AD). A large sample of participants (570) completed a switching task in which participants were cued to classify the letter (consonant/vowel) or number (odd/even) task-set dimension of a bivalent stimulus (e.g., A 14), respectively. A Pure block consisting of single-task trials and a Switch block consisting of nonswitch and switch trials were completed. Local (switch vs. nonswitch trials) and global (nonswitch vs. pure trials) costs in mean error rates, mean response latencies, underlying reaction time distributions, along with stimulus-response congruency effects were computed. Local costs in errors were group invariant, but global costs in errors systematically increased as a function of age and AD. Response latencies yielded a strong dissociation: Local costs decreased across groups whereas global costs increased across groups. Vincentile distribution analyses revealed that the dissociation of local and global costs primarily occurred in the slowest response latencies. Stimulus-response congruency effects within the Switch block were particularly robust in accuracy in the very mild AD group. We argue that the results are consistent with the notion that the impaired groups show a reduced local cost because the task sets are not as well tuned, and hence produce minimal cost on switch trials. In contrast, global costs increase because of the additional burden on working memory of maintaining two task sets. PMID:26652720
Rein, David B; Wittenborn, John S; Zhang, Xinzhi; Allaire, Benjamin A; Song, Michael S; Klein, Ronald; Saaddine, Jinan B
2011-01-01
Objective To determine whether biennial eye evaluation or telemedicine screening are cost-effective alternatives to current recommendations for the estimated 10 million people aged 30–84 with diabetes but no or minimal diabetic retinopathy. Data Sources United Kingdom Prospective Diabetes Study, National Health and Nutrition Examination Survey, American Academy of Ophthalmology Preferred Practice Patterns, Medicare Payment Schedule. Study Design Cost-effectiveness Monte Carlo simulation. Data Collection/Extraction Methods Literature review, analysis of existing surveys. Principal Findings Biennial eye evaluation was the most cost-effective treatment option when the ability to detect other eye conditions was included in the model. Telemedicine was most cost-effective when other eye conditions were not considered or when telemedicine was assumed to detect refractive error. The current annual eye evaluation recommendation was costly compared with either treatment alternative. Self-referral was most cost-effective up to a willingness to pay (WTP) of U.S.$37,600, with either biennial or annual evaluation most cost-effective at higher WTP levels. Conclusions Annual eye evaluations are costly and add little benefit compared with either plausible alternative. More research on the ability of telemedicine to detect other eye conditions is needed to determine whether it is more cost-effective than biennial eye evaluation. PMID:21492158
Scotland, G S; McNamee, P; Fleming, A D; Goatman, K A; Philip, S; Prescott, G J; Sharp, P F; Williams, G J; Wykes, W; Leese, G P; Olson, J A
2010-06-01
To assess the cost-effectiveness of an improved automated grading algorithm for diabetic retinopathy against a previously described algorithm, and in comparison with manual grading. Efficacy of the alternative algorithms was assessed using a reference graded set of images from three screening centres in Scotland (1253 cases with observable/referable retinopathy and 6333 individuals with mild or no retinopathy). Screening outcomes and grading and diagnosis costs were modelled for a cohort of 180 000 people, with prevalence of referable retinopathy at 4%. Algorithm (b), which combines image quality assessment with detection algorithms for microaneurysms (MA), blot haemorrhages and exudates, was compared with a simpler algorithm (a) (using image quality assessment and MA/dot haemorrhage (DH) detection), and the current practice of manual grading. Compared with algorithm (a), algorithm (b) would identify an additional 113 cases of referable retinopathy for an incremental cost of pound 68 per additional case. Compared with manual grading, automated grading would be expected to identify between 54 and 123 fewer referable cases, for a grading cost saving between pound 3834 and pound 1727 per case missed. Extrapolation modelling over a 20-year time horizon suggests manual grading would cost between pound 25,676 and pound 267,115 per additional quality adjusted life year gained. Algorithm (b) is more cost-effective than the algorithm based on quality assessment and MA/DH detection. With respect to the value of introducing automated detection systems into screening programmes, automated grading operates within the recommended national standards in Scotland and is likely to be considered a cost-effective alternative to manual disease/no disease grading.
Roberts, T; Mugford, M; Piercy, J
1998-09-01
To compare the cost effectiveness of different programmes of routine antenatal ultrasound screening to detect four key fetal anomalies: serious cardiac anomalies, spina bifida, Down's syndrome and lethal anomalies, using existing evidence. Decision analysis was used based on the best data currently available, including expert opinion from the Royal College of Obstetricians and Gynaecologists, Working Party and secondary data from the literature, to predict the likely outcomes in terms of malformations detected by each screening programme. Results applicable in clinics, hospitals or GP practices delivering antenatal screening. The number of cases with a 'target' malformation correctly detected antenatally. There was substantial overlap between the cost ranges of each screening programme demonstrating considerable uncertainty about the relative economic efficiency of alternative programmes for ultrasound screening. The cheapest, but not the most effective, screening programme consisted of one second trimester ultrasound scan. The cost per target anomaly detected (cost effectiveness) for this programme was in the range 5,000 pound silver-109,000, pound silver but in any 1000 women it will also fail to detect between 3.6 and 4.7 target anomalies. The range of uncertainty in the costs did not allow selection of any one programme as a clear choice for NHS purchasers. The results suggested that the overall allocation of resources for routine ultrasound screening in the UK is not currently economically efficient, but that certain scenarios for ultrasound screening are potentially within the range of cost effectiveness reached by other, possibly competing, screening programmes. The model highlighted the weakness of available evidence and demonstrated the need for more information both about current practice and costs.
Nanotextured thin films for detection of chemicals by surface enhanced Raman scattering
NASA Astrophysics Data System (ADS)
Korivi, Naga; Jiang, Li; Ahmed, Syed; Nujhat, Nabila; Idrees, Mohanad; Rangari, Vijaya
2017-11-01
We report on the development of large area, nanostructured films that function as substrates for surface enhanced Raman scattering (SERS) detection of chemicals. The films are made of polyethylene terephthalate layers partially embedded with multi-walled carbon nanotubes and coated with a thin layer of gold. The films are fabricated by a facile method involving spin-coating, acid dip, and magnetron sputtering. The films perform effectively as SERS substrates when used in the detection of dye pollutants such as Congo red dye, with an enhancement factor of 1.1 × 106 and a detection limit of 10-7 M which is the lowest reported for CR detection by freestanding SERS film substrates. The films have a long shelf life, and cost US0.20 per cm2 of active area, far less than commercially available SERS substrates. This is the first such work on the use of a polymer layer modified with carbon nanotubes to create a nano-scale texture and arbitrary ‘hot-spots’, contributing to the SERS effect.
Computer-Aided Detection of Prostate Cancer with MRI: Technology and Applications
Liu, Lizhi; Tian, Zhiqiang; Zhang, Zhenfeng; Fei, Baowei
2016-01-01
One in six men will develop prostate cancer in his life time. Early detection and accurate diagnosis of the disease can improve cancer survival and reduce treatment costs. Recently, imaging of prostate cancer has greatly advanced since the introduction of multi-parametric magnetic resonance imaging (mp-MRI). Mp-MRI consists of T2-weighted sequences combined with functional sequences including dynamic contrast-enhanced MRI, diffusion-weighted MRI, and MR spectroscopy imaging. Due to the big data and variations in imaging sequences, detection can be affected by multiple factors such as observer variability and visibility and complexity of the lesions. In order to improve quantitative assessment of the disease, various computer-aided detection systems have been designed to help radiologists in their clinical practice. This review paper presents an overview of literatures on computer-aided detection of prostate cancer with mp-MRI, which include the technology and its applications. The aim of the survey is threefold: an introduction for those new to the field, an overview for those working in the field, and a reference for those searching for literature on a specific application. PMID:27133005
Using Dictionary Pair Learning for Seizure Detection.
Ma, Xin; Yu, Nana; Zhou, Weidong
2018-02-13
Automatic seizure detection is extremely important in the monitoring and diagnosis of epilepsy. The paper presents a novel method based on dictionary pair learning (DPL) for seizure detection in the long-term intracranial electroencephalogram (EEG) recordings. First, for the EEG data, wavelet filtering and differential filtering are applied, and the kernel function is performed to make the signal linearly separable. In DPL, the synthesis dictionary and analysis dictionary are learned jointly from original training samples with alternating minimization method, and sparse coefficients are obtained by using of linear projection instead of costly [Formula: see text]-norm or [Formula: see text]-norm optimization. At last, the reconstructed residuals associated with seizure and nonseizure sub-dictionary pairs are calculated as the decision values, and the postprocessing is performed for improving the recognition rate and reducing the false detection rate of the system. A total of 530[Formula: see text]h from 20 patients with 81 seizures were used to evaluate the system. Our proposed method has achieved an average segment-based sensitivity of 93.39%, specificity of 98.51%, and event-based sensitivity of 96.36% with false detection rate of 0.236/h.
More, S J; Cameron, A R; Strain, S; Cashman, W; Ezanno, P; Kenny, K; Fourichon, C; Graham, D
2015-08-01
As part of a broader control strategy within herds known to be infected with Mycobacterium avium ssp. paratuberculosis (MAP), individual animal testing is generally conducted to identify infected animals for action, usually culling. Opportunities are now available to quantitatively compare different testing strategies (combinations of tests) in known infected herds. This study evaluates the effectiveness, cost, and cost-effectiveness of different testing strategies to identify infected animals at a single round of testing within dairy herds known to be MAP infected. A model was developed, taking account of both within-herd infection dynamics and test performance, to simulate the use of different tests at a single round of testing in a known infected herd. Model inputs included the number of animals at different stages of infection, the sensitivity and specificity of each test, and the costs of testing and culling. Testing strategies included either milk or serum ELISA alone or with fecal culture in series. Model outputs included effectiveness (detection fraction, the proportion of truly infected animals in the herd that are successfully detected by the testing strategy), cost, and cost-effectiveness (testing cost per true positive detected, total cost per true positive detected). Several assumptions were made: MAP was introduced with a single animal and no management interventions were implemented to limit within-herd transmission of MAP before this test. In medium herds, between 7 and 26% of infected animals are detected at a single round of testing, the former using the milk ELISA and fecal culture in series 5 yr after MAP introduction and the latter using fecal culture alone 15 yr after MAP introduction. The combined costs of testing and culling at a single round of testing increases with time since introduction of MAP infection, with culling costs being much greater than testing costs. The cost-effectiveness of testing varied by testing strategy. It was also greater at 5 yr, compared with 10 or 15 yr, since MAP introduction, highlighting the importance of early detection. Future work is needed to evaluate these testing strategies in subsequent rounds of testing as well as accounting for different herd dynamics and different levels of herd biocontainment. Copyright © 2015 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Cost characteristics of hospitals.
Smet, Mike
2002-09-01
Modern hospitals are complex multi-product organisations. The analysis of a hospital's production and/or cost structure should therefore use the appropriate techniques. Flexible functional forms based on the neo-classical theory of the firm seem to be most suitable. Using neo-classical cost functions implicitly assumes minimisation of (variable) costs given that input prices and outputs are exogenous. Local and global properties of flexible functional forms and short-run versus long-run equilibrium are further issues that require thorough investigation. In order to put the results based on econometric estimations of cost functions in the right perspective, it is important to keep these considerations in mind when using flexible functional forms. The more recent studies seem to agree that hospitals generally do not operate in their long-run equilibrium (they tend to over-invest in capital (capacity and equipment)) and that it is therefore appropriate to estimate a short-run variable cost function. However, few studies explicitly take into account the implicit assumptions and restrictions embedded in the models they use. An alternative method to explain differences in costs uses management accounting techniques to identify the cost drivers of overhead costs. Related issues such as cost-shifting and cost-adjusting behaviour of hospitals and the influence of market structure on competition, prices and costs are also discussed shortly.
The cost of sustaining a patient-centered medical home: experience from 2 states.
Magill, Michael K; Ehrenberger, David; Scammon, Debra L; Day, Julie; Allen, Tatiana; Reall, Andreu J; Sides, Rhonda W; Kim, Jaewhan
2015-09-01
As medical practices transform to patient-centered medical homes (PCMHs), it is important to identify the ongoing costs of maintaining these "advanced primary care" functions. A key required input is personnel effort. This study's objective was to assess direct personnel costs to practices associated with the staffing necessary to deliver PCMH functions as outlined in the National Committee for Quality Assurance Standards. We developed a PCMH cost dimensions tool to assess costs associated with activities uniquely required to maintain PCMH functions. We interviewed practice managers, nurse supervisors, and medical directors in 20 varied primary care practices in 2 states, guided by the tool. Outcome measures included categories of staff used to perform various PCMH functions, time and personnel costs, and whether practices were delivering PCMH functions. Costs per full-time equivalent primary care clinician associated with PCMH functions varied across practices with an average of $7,691 per month in Utah practices and $9,658 in Colorado practices. PCMH incremental costs per encounter were $32.71 in Utah and $36.68 in Colorado. The average estimated cost per member per month for an assumed panel of 2,000 patients was $3.85 in Utah and $4.83 in Colorado. Identifying costs of maintaining PCMH functions will contribute to effective payment reform and to sustainability of transformation. Maintenance and ongoing support of PCMH functions require additional time and new skills, which may be provided by existing staff, additional staff, or both. Adequate compensation for ongoing and substantial incremental costs is critical for practices to sustain PCMH functions. © 2015 Annals of Family Medicine, Inc.
The Cost of Sustaining a Patient-Centered Medical Home: Experience From 2 States
Magill, Michael K.; Ehrenberger, David; Scammon, Debra L.; Day, Julie; Allen, Tatiana; Reall, Andreu J.; Sides, Rhonda W.; Kim, Jaewhan
2015-01-01
PURPOSE As medical practices transform to patient-centered medical homes (PCMHs), it is important to identify the ongoing costs of maintaining these “advanced primary care” functions. A key required input is personnel effort. This study’s objective was to assess direct personnel costs to practices associated with the staffing necessary to deliver PCMH functions as outlined in the National Committee for Quality Assurance Standards. METHODS We developed a PCMH cost dimensions tool to assess costs associated with activities uniquely required to maintain PCMH functions. We interviewed practice managers, nurse supervisors, and medical directors in 20 varied primary care practices in 2 states, guided by the tool. Outcome measures included categories of staff used to perform various PCMH functions, time and personnel costs, and whether practices were delivering PCMH functions. RESULTS Costs per full-time equivalent primary care clinician associated with PCMH functions varied across practices with an average of $7,691 per month in Utah practices and $9,658 in Colorado practices. PCMH incremental costs per encounter were $32.71 in Utah and $36.68 in Colorado. The average estimated cost per member per month for an assumed panel of 2,000 patients was $3.85 in Utah and $4.83 in Colorado. CONCLUSIONS Identifying costs of maintaining PCMH functions will contribute to effective payment reform and to sustainability of transformation. Maintenance and ongoing support of PCMH functions require additional time and new skills, which may be provided by existing staff, additional staff, or both. Adequate compensation for ongoing and substantial incremental costs is critical for practices to sustain PCMH functions. PMID:26371263
Methods and approaches of utilizing ionic liquids as gas sensing materials
Rehman, Abdul
2017-01-01
Gas monitoring is of increasing significance for a broad range of applications in the fields of environmental and civil infrastructures, climate and energy, health and safety, industry and commerce. Even though there are many gas detection devices and systems available, the increasing needs for better detection technologies that not only satisfy the high analytical standards but also meet additional device requirements (e.g., being robust to survive under field conditions, low cost, small, smart, more mobile), demand continuous efforts in developing new methods and approaches for gas detection. Ionic Liquids (ILs) have attracted a tremendous interest as potential sensing materials for the gas sensor development. Being composed entirely of ions and with a broad structural and functional diversity, i.e., bifunctional (organic/inorganic), biphasic (solid/liquid) and dual-property (solvent/electrolyte), they have the complementing attributes and the required variability to allow a systematic design process across many sensing components to enhance sensing capability especially for miniaturized sensor system implementation. The emphasis of this review is to describe molecular design and control of IL interface materials to provide selective and reproducible response and to synergistically integrate IL sensing materials with low cost and low power electrochemical, piezoelectric/QCM and optical transducers to address many gas detection challenges (e.g., sensitivity, selectivity, reproducibility, speed, stability, cost, sensor miniaturization, and robustness). We further show examples to justify the importance of understanding the mechanisms and principles of physicochemical and electrochemical reactions in ILs and then link those concepts to developing new sensing methods and approaches. By doing this, we hope to stimulate further research towards the fundamental understanding of the sensing mechanisms and new sensor system development and integration, using simple sensing designs and flexible sensor structures both in terms of scientific operation and user interface that can be miniaturized and interfaced with modern wireless monitoring technologies to achieve specifications heretofore unavailable on current markets for the next generation of gas sensor applications. PMID:29142738
2009-07-28
To estimate the cost effectiveness of alternative methods of managing low grade cervical cytological abnormalities detected at routine screening. Design Cost analysis within multicentre individually randomised controlled trial. Grampian, Tayside, and Nottingham. 4201 women with low grade abnormalities. Cytological surveillance or referral to colposcopy for biopsy and recall if necessary or referral to colposcopy with immediate treatment based on colposcopic appearance. Data on resource use collected from participants throughout the duration of the trial (36 months), enabling the estimation of both the direct (health care) and indirect (time and travel) costs of management. Quality of life assessed at recruitment and at 12, 18, 24, and 30 months, using the EQ-5D instrument. Economic outcomes expressed as costs per case of cervical intraepithelial neoplasia (grade II or worse) detected, by trial arm, as confirmed at exit, and cost utility ratios (cost per quality adjusted life year (QALY) gained) for the three pairwise comparisons of trial arms. The mean three year discounted costs of surveillance, immediate treatment, and biopsy and recall were pound150.20 (euro177, $249), pound240.30 (euro283, $415), and pound241.10 (euro284, $4000), respectively, viewed from the health service perspective. From the social perspective, mean discounted costs were pound204.40 (euro241, $339), pound339.90 (euro440, $563), and pound327.50 (euro386, $543), respectively. Estimated at the means, the incremental cost effectiveness ratios indicated that immediate treatment was dominated by the other two management methods, although it did offer the lowest cost per case of cervical intraepithelial neoplasia detected and treated. The pronounced skews in the distributions indicated that probabilistic uncertainty analysis would offer more meaningful estimates of cost effectiveness. The observed differences in the cost effectiveness ratios between trial arms were not significant. Judged within the time frame of the TOMBOLA evaluation, there is no compelling economic reason to favour any one follow-up method over either of the others. ISRCTN 34841617.
Morris, Stephen; Karlsen, Saffron; Chung, Nancy; Hill, Melissa; Chitty, Lyn S
2014-01-01
Non-invasive prenatal testing (NIPT) for Down's syndrome (DS) using cell free fetal DNA in maternal blood has the potential to dramatically alter the way prenatal screening and diagnosis is delivered. Before NIPT can be implemented into routine practice, information is required on its costs and benefits. We investigated the costs and outcomes of NIPT for DS as contingent testing and as first-line testing compared with the current DS screening programme in the UK National Health Service. We used a pre-existing model to evaluate the costs and outcomes associated with NIPT compared with the current DS screening programme. The analysis was based on a hypothetical screening population of 10,000 pregnant women. Model inputs were taken from published sources. The main outcome measures were number of DS cases detected, number of procedure-related miscarriages and total cost. At a screening risk cut-off of 1∶150 NIPT as contingent testing detects slightly fewer DS cases, has fewer procedure-related miscarriages, and costs the same as current DS screening (around UK£280,000) at a cost of £500 per NIPT. As first-line testing NIPT detects more DS cases, has fewer procedure-related miscarriages, and is more expensive than current screening at a cost of £50 per NIPT. When NIPT uptake increases, NIPT detects more DS cases with a small increase in procedure-related miscarriages and costs. NIPT is currently available in the private sector in the UK at a price of £400-£900. If the NHS cost was at the lower end of this range then at a screening risk cut-off of 1∶150 NIPT as contingent testing would be cost neutral or cost saving compared with current DS screening. As first-line testing NIPT is likely to produce more favourable outcomes but at greater cost. Further research is needed to evaluate NIPT under real world conditions.
Smith, David H; O'Keeffe Rosetti, Maureen; Mosen, David M; Rosales, A Gabriela; Keast, Erin; Perrin, Nancy; Feldstein, Adrianne C; Levin, Theodore R; Liles, Elizabeth G
2018-06-21
Colorectal cancer (CRC) causes more than 50,000 deaths each year in the United States but early detection through screening yields survival gains; those diagnosed with early stage disease have a 5-year survival greater than 90%, compared to 12% for those diagnosed with late stage disease. Using data from a large integrated health system, this study evaluates the cost-effectiveness of fecal immunochemical testing (FIT), a common CRC screening tool. A probabilistic decision-analytic model was used to examine the costs and outcomes of positive test results from a 1-FIT regimen compared with a 2-FIT regimen. The authors compared 5 diagnostic cutoffs of hemoglobin concentration for each test (for a total of 10 screening options). The principal outcome from the analysis was the cost per additional advanced neoplasia (AN) detected. The authors also estimated the number of cancers detected and life-years gained from detecting AN. The following costs were included: program management of the screening program, patient identification, FIT kits and their processing, and diagnostic colonoscopy following a positive FIT. Per-person costs ranged from $33 (1-FIT at 150ng/ml) to $92 (2-FIT at 50ng/ml) across screening options. Depending on willingness to pay, the 1-FIT 50 ng/ml and the 2-FIT 50 ng/ml are the dominant strategies with cost-effectiveness of $11,198 and $28,389, respectively, for an additional AN detected. The estimates of cancers avoided per 1000 screens ranged from 1.46 to 4.86, depending on the strategy and the assumptions of AN to cancer progression.
Integrated Device for Circulating Tumor Cell Capture, Characterization and Lens-Free Microscopy
2012-08-01
peripheral blood of breast cancer patients indicates high metastatic potential and increased morbidity. Development of a cost - effective CTC detection and...microfilter platform captures CTC from the cancer patients’ blood cost effectively , where the larger CTC are preferentially retained on the membrane...development of a cost - effective and high-throughput CTC analysis system would revolutionize the field of CTC detection, prognosis, and therapeutic
Khaparde, Sunil; Nair, Sreenivas Achuthan; Denkinger, Claudia; Sachdeva, Kuldeep Singh; Paramasivan, Chinnambedu Nainarappan; Salhotra, Virender Singh; Vassall, Anna; Hoog, Anja van't
2017-01-01
Background India is considering the scale-up of the Xpert MTB/RIF assay for detection of tuberculosis (TB) and rifampicin resistance. We conducted an economic analysis to estimate the costs of different strategies of Xpert implementation in India. Methods Using a decision analytical model, we compared four diagnostic strategies for TB patients: (i) sputum smear microscopy (SSM) only; (ii) Xpert as a replacement for the rapid diagnostic test currently used for SSM-positive patients at risk of drug resistance (i.e. line probe assay (LPA)); (iii) Upfront Xpert testing for patients at risk of drug resistance; and (iv) Xpert as a replacement for SSM for all patients. Results The total costs associated with diagnosis for 100,000 presumptive TB cases were: (i) US$ 619,042 for SSM-only; (ii) US$ 575,377 in the LPA replacement scenario; (iii) US$ 720,523 in the SSM replacement scenario; and (iv) US$ 1,639,643 in the Xpert-for-all scenario. Total cohort costs, including treatment costs, increased by 46% from the SSM-only to the Xpert-for-all strategy, largely due to the costs associated with second-line treatment of a higher number of rifampicin-resistant patients due to increased drug-resistant TB (DR-TB) case detection. The diagnostic costs for an estimated 7.64 million presumptive TB patients would comprise (i) 19%, (ii) 17%, (iii) 22% and (iv) 50% of the annual TB control budget. Mean total costs, expressed per DR-TB case initiated on treatment, were lowest in the Xpert-for-all scenario (US$ 11,099). Conclusions The Xpert-for-all strategy would result in the greatest increase of TB and DR-TB case detection, but would also have the highest associated costs. The strategy of using Xpert only for patients at risk for DR-TB would be more affordable, but would miss DR-TB cases and the cost per true DR-TB case detected would be higher compared to the Xpert-for-all strategy. As such expanded Xpert strategy would require significant increased TB control budget to ensure that increased case detection is followed by appropriate care. PMID:28880875
Isofunctional Protein Subfamily Detection Using Data Integration and Spectral Clustering.
Boari de Lima, Elisa; Meira, Wagner; Melo-Minardi, Raquel Cardoso de
2016-06-01
As increasingly more genomes are sequenced, the vast majority of proteins may only be annotated computationally, given experimental investigation is extremely costly. This highlights the need for computational methods to determine protein functions quickly and reliably. We believe dividing a protein family into subtypes which share specific functions uncommon to the whole family reduces the function annotation problem's complexity. Hence, this work's purpose is to detect isofunctional subfamilies inside a family of unknown function, while identifying differentiating residues. Similarity between protein pairs according to various properties is interpreted as functional similarity evidence. Data are integrated using genetic programming and provided to a spectral clustering algorithm, which creates clusters of similar proteins. The proposed framework was applied to well-known protein families and to a family of unknown function, then compared to ASMC. Results showed our fully automated technique obtained better clusters than ASMC for two families, besides equivalent results for other two, including one whose clusters were manually defined. Clusters produced by our framework showed great correspondence with the known subfamilies, besides being more contrasting than those produced by ASMC. Additionally, for the families whose specificity determining positions are known, such residues were among those our technique considered most important to differentiate a given group. When run with the crotonase and enolase SFLD superfamilies, the results showed great agreement with this gold-standard. Best results consistently involved multiple data types, thus confirming our hypothesis that similarities according to different knowledge domains may be used as functional similarity evidence. Our main contributions are the proposed strategy for selecting and integrating data types, along with the ability to work with noisy and incomplete data; domain knowledge usage for detecting subfamilies in a family with different specificities, thus reducing the complexity of the experimental function characterization problem; and the identification of residues responsible for specificity.
Isofunctional Protein Subfamily Detection Using Data Integration and Spectral Clustering
Boari de Lima, Elisa; Meira, Wagner; de Melo-Minardi, Raquel Cardoso
2016-01-01
As increasingly more genomes are sequenced, the vast majority of proteins may only be annotated computationally, given experimental investigation is extremely costly. This highlights the need for computational methods to determine protein functions quickly and reliably. We believe dividing a protein family into subtypes which share specific functions uncommon to the whole family reduces the function annotation problem’s complexity. Hence, this work’s purpose is to detect isofunctional subfamilies inside a family of unknown function, while identifying differentiating residues. Similarity between protein pairs according to various properties is interpreted as functional similarity evidence. Data are integrated using genetic programming and provided to a spectral clustering algorithm, which creates clusters of similar proteins. The proposed framework was applied to well-known protein families and to a family of unknown function, then compared to ASMC. Results showed our fully automated technique obtained better clusters than ASMC for two families, besides equivalent results for other two, including one whose clusters were manually defined. Clusters produced by our framework showed great correspondence with the known subfamilies, besides being more contrasting than those produced by ASMC. Additionally, for the families whose specificity determining positions are known, such residues were among those our technique considered most important to differentiate a given group. When run with the crotonase and enolase SFLD superfamilies, the results showed great agreement with this gold-standard. Best results consistently involved multiple data types, thus confirming our hypothesis that similarities according to different knowledge domains may be used as functional similarity evidence. Our main contributions are the proposed strategy for selecting and integrating data types, along with the ability to work with noisy and incomplete data; domain knowledge usage for detecting subfamilies in a family with different specificities, thus reducing the complexity of the experimental function characterization problem; and the identification of residues responsible for specificity. PMID:27348631
Cost of services provided by the National Breast and Cervical Cancer Early Detection Program.
Ekwueme, Donatus U; Subramanian, Sujha; Trogdon, Justin G; Miller, Jacqueline W; Royalty, Janet E; Li, Chunyu; Guy, Gery P; Crouse, Wesley; Thompson, Hope; Gardner, James G
2014-08-15
The National Breast and Cervical Cancer Early Detection Program (NBCCEDP) is the largest cancer screening program for low-income women in the United States. This study updates previous estimates of the costs of delivering preventive cancer screening services in the NBCCEDP. We developed a standardized web-based cost-assessment tool to collect annual activity-based cost data on screening for breast and cervical cancer in the NBCCEDP. Data were collected from 63 of the 66 programs that received funding from the Centers for Disease Control and Prevention during the 2006/2007 fiscal year. We used these data to calculate costs of delivering preventive public health services in the program. We estimated the total cost of all NBCCEDP services to be $296 (standard deviation [SD], $123) per woman served (including the estimated value of in-kind donations, which constituted approximately 15% of this total estimated cost). The estimated cost of screening and diagnostic services was $145 (SD, $38) per women served, which represented 57.7% of the total cost excluding the value of in-kind donations. Including the value of in-kind donations, the weighted mean cost of screening a woman for breast cancer was $110 with an office visit and $88 without, the weighted mean cost of a diagnostic procedure was $401, and the weighted mean cost per breast cancer detected was $35,480. For cervical cancer, the corresponding cost estimates were $61, $21, $415, and $18,995, respectively. These NBCCEDP cost estimates may help policy makers in planning and implementing future costs for various potential changes to the program. © 2014 American Cancer Society.
Laxy, Michael; Wilson, Edward C F; Boothby, Clare E; Griffin, Simon J
2017-12-01
There is uncertainty about the cost effectiveness of early intensive treatment versus routine care in individuals with type 2 diabetes detected by screening. To derive a trial-informed estimate of the incremental costs of intensive treatment as delivered in the Anglo-Danish-Dutch Study of Intensive Treatment in People with Screen-Detected Diabetes in Primary Care-Europe (ADDITION) trial and to revisit the long-term cost-effectiveness analysis from the perspective of the UK National Health Service. We analyzed the electronic primary care records of a subsample of the ADDITION-Cambridge trial cohort (n = 173). Unit costs of used primary care services were taken from the published literature. Incremental annual costs of intensive treatment versus routine care in years 1 to 5 after diagnosis were calculated using multilevel generalized linear models. We revisited the long-term cost-utility analyses for the ADDITION-UK trial cohort and reported results for ADDITION-Cambridge using the UK Prospective Diabetes Study Outcomes Model and the trial-informed cost estimates according to a previously developed evaluation framework. Incremental annual costs of intensive treatment over years 1 to 5 averaged £29.10 (standard error = £33.00) for consultations with general practitioners and nurses and £54.60 (standard error = £28.50) for metabolic and cardioprotective medication. For ADDITION-UK, over the 10-, 20-, and 30-year time horizon, adjusted incremental quality-adjusted life-years (QALYs) were 0.014, 0.043, and 0.048, and adjusted incremental costs were £1,021, £1,217, and £1,311, resulting in incremental cost-effectiveness ratios of £71,232/QALY, £28,444/QALY, and £27,549/QALY, respectively. Respective incremental cost-effectiveness ratios for ADDITION-Cambridge were slightly higher. The incremental costs of intensive treatment as delivered in the ADDITION-Cambridge trial were lower than expected. Given UK willingness-to-pay thresholds in patients with screen-detected diabetes, intensive treatment is of borderline cost effectiveness over a time horizon of 20 years and more. Copyright © 2017. Published by Elsevier Inc.
Randomized Trial of Intelligent Sensor System for Early Illness Alerts in Senior Housing.
Rantz, Marilyn; Phillips, Lorraine J; Galambos, Colleen; Lane, Kari; Alexander, Gregory L; Despins, Laurel; Koopman, Richelle J; Skubic, Marjorie; Hicks, Lanis; Miller, Steven; Craver, Andy; Harris, Bradford H; Deroche, Chelsea B
2017-10-01
Measure the clinical effectiveness and cost effectiveness of using sensor data from an environmentally embedded sensor system for early illness recognition. This sensor system has demonstrated in pilot studies to detect changes in function and in chronic diseases or acute illnesses on average 10 days to 2 weeks before usual assessment methods or self-reports of illness. Prospective intervention study in 13 assisted living (AL) communities of 171 residents randomly assigned to intervention (n=86) or comparison group (n=85) receiving usual care. Intervention participants lived with the sensor system an average of one year. Continuous data collected 24 hours/7 days a week from motion sensors to measure overall activity, an under mattress bed sensor to capture respiration, pulse, and restlessness as people sleep, and a gait sensor that continuously measures gait speed, stride length and time, and automatically assess for increasing fall risk as the person walks around the apartment. Continuously running computer algorithms are applied to the sensor data and send health alerts to staff when there are changes in sensor data patterns. The randomized comparison group functionally declined more rapidly than the intervention group. Walking speed and several measures from GaitRite, velocity, step length left and right, stride length left and right, and the fall risk measure of functional ambulation profile (FAP) all had clinically significant changes. The walking speed increase (worse) and velocity decline (worse) of 0.073 m/s for comparison group exceeded 0.05 m/s, a value considered to be a minimum clinically important difference. No differences were measured in health care costs. These findings demonstrate that sensor data with health alerts and fall alerts sent to AL nursing staff can be an effective strategy to detect and intervene in early signs of illness or functional decline. Copyright © 2017 AMDA – The Society for Post-Acute and Long-Term Care Medicine. Published by Elsevier Inc. All rights reserved.
A self-made, low-cost infrared system for evaluating the sciatic functional index in mice.
Fricker, Lukas; Penna, Vincenzo; Lampert, Florian; Stark, G Bjoern; Witzel, Christian; Koulaxouzidis, Georgios
2016-05-01
The sciatic functional index (SFI) is a popular parameter for peripheral nerve evaluation that relies on footprints obtained with ink and paper. Drawbacks include smearing artefacts and a lack of dynamic information during measurement. Modern applications use digitized systems that can deliver results with less analytical effort and fewer mice. However, the systems are expensive (€40,000). This study aimed to evaluate the applicability and precision of a self-made, low-cost infrared system for evaluating SFI in mice. Mice were subjected to unilateral sciatic nerve crush injury (crush group; n = 7) and sham operation (sham group; n = 4). They were evaluated on the day before surgery, the 2(nd), 4(th) and 6(th) days after injury, and then every day up to the 23(rd) day after injury. We compared two SFI evaluation methods, i.e., conventional ink-and-paper SFI (C-SFI) and our infrared system (I-SFI). Our apparatus visualized footprints with totally internally reflected infrared light (950 nm) and a camera that can only detect this wavelength. Additionally we performed an analysis with the ladder beam walking test (LBWT) as a reference test. I-SFI assessment reduced the standard deviation by about 33 percent, from 11.6 to 7.8, and cut the variance around the baseline to 21 percent. The system thus requires fewer measurement repetitions and fewer animals, and cuts the cost of keeping the animals. The apparatus cost €321 to build. Our results show that the process of obtaining the SFI can be made more precise via digitization with a self-made, low-cost infrared system.
A self-made, low-cost infrared system for evaluating the sciatic functional index in mice
Fricker, Lukas; Penna, Vincenzo; Lampert, Florian; Stark, G. Bjoern; Witzel, Christian; Koulaxouzidis, Georgios
2016-01-01
The sciatic functional index (SFI) is a popular parameter for peripheral nerve evaluation that relies on footprints obtained with ink and paper. Drawbacks include smearing artefacts and a lack of dynamic information during measurement. Modern applications use digitized systems that can deliver results with less analytical effort and fewer mice. However, the systems are expensive (€40,000). This study aimed to evaluate the applicability and precision of a self-made, low-cost infrared system for evaluating SFI in mice. Mice were subjected to unilateral sciatic nerve crush injury (crush group; n = 7) and sham operation (sham group; n = 4). They were evaluated on the day before surgery, the 2nd, 4th and 6th days after injury, and then every day up to the 23rd day after injury. We compared two SFI evaluation methods, i.e., conventional ink-and-paper SFI (C-SFI) and our infrared system (I-SFI). Our apparatus visualized footprints with totally internally reflected infrared light (950 nm) and a camera that can only detect this wavelength. Additionally we performed an analysis with the ladder beam walking test (LBWT) as a reference test. I-SFI assessment reduced the standard deviation by about 33 percent, from 11.6 to 7.8, and cut the variance around the baseline to 21 percent. The system thus requires fewer measurement repetitions and fewer animals, and cuts the cost of keeping the animals. The apparatus cost €321 to build. Our results show that the process of obtaining the SFI can be made more precise via digitization with a self-made, low-cost infrared system. PMID:27335570
2011-01-01
Background Single reading with computer aided detection (CAD) is an alternative to double reading for detecting cancer in screening mammograms. The aim of this study is to investigate whether the use of a single reader with CAD is more cost-effective than double reading. Methods Based on data from the CADET II study, the cost-effectiveness of single reading with CAD versus double reading was measured in terms of cost per cancer detected. Cost (Pound (£), year 2007/08) of single reading with CAD versus double reading was estimated assuming a health and social service perspective and a 7 year time horizon. As the equipment cost varies according to the unit size a separate analysis was conducted for high, average and low volume screening units. One-way sensitivity analyses were performed by varying the reading time, equipment and assessment cost, recall rate and reader qualification. Results CAD is cost increasing for all sizes of screening unit. The introduction of CAD is cost-increasing compared to double reading because the cost of CAD equipment, staff training and the higher assessment cost associated with CAD are greater than the saving in reading costs. The introduction of single reading with CAD, in place of double reading, would produce an additional cost of £227 and £253 per 1,000 women screened in high and average volume units respectively. In low volume screening units, the high cost of purchasing the equipment will results in an additional cost of £590 per 1,000 women screened. One-way sensitivity analysis showed that the factors having the greatest effect on the cost-effectiveness of CAD with single reading compared with double reading were the reading time and the reader's professional qualification (radiologist versus advanced practitioner). Conclusions Without improvements in CAD effectiveness (e.g. a decrease in the recall rate) CAD is unlikely to be a cost effective alternative to double reading for mammography screening in UK. This study provides updated estimates of CAD costs in a full-field digital system and assessment cost for women who are re-called after initial screening. However, the model is highly sensitive to various parameters e.g. reading time, reader qualification, and equipment cost. PMID:21241473
Detection of Bacteria Using Inkjet-Printed Enzymatic Test Strips
2015-01-01
Low-cost diagnostics for drinking water contamination have the potential to save millions of lives. We report a method that uses inkjet printing to copattern an enzyme–nanoparticle sensor and substrate on a paper-based test strip for rapid detection of bacteria. A colorimetric response is generated on the paper substrate that allows visual detection of contamination without the need for expensive instrumentation. These strips demonstrate a viable nanomanufacturing strategy for low-cost bacterial detection. PMID:25318086
Cost-Effectiveness of Diagnostic Strategies for Suspected Scaphoid Fractures.
Yin, Zhong-Gang; Zhang, Jian-Bing; Gong, Ke-Tong
2015-08-01
The aim of this study was to assess the cost effectiveness of multiple competing diagnostic strategies for suspected scaphoid fractures. With published data, the authors created a decision-tree model simulating the diagnosis of suspected scaphoid fractures. Clinical outcomes, costs, and cost effectiveness of immediate computed tomography (CT), day 3 magnetic resonance imaging (MRI), day 3 bone scan, week 2 radiographs alone, week 2 radiographs-CT, week 2 radiographs-MRI, week 2 radiographs-bone scan, and immediate MRI were evaluated. The primary clinical outcome was the detection of scaphoid fractures. The authors adopted societal perspective, including both the costs of healthcare and the cost of lost productivity. The incremental cost-effectiveness ratio (ICER), which expresses the incremental cost per incremental scaphoid fracture detected using a strategy, was calculated to compare these diagnostic strategies. Base case analysis, 1-way sensitivity analyses, and "worst case scenario" and "best case scenario" sensitivity analyses were performed. In the base case, the average cost per scaphoid fracture detected with immediate CT was $2553. The ICER of immediate MRI and day 3 MRI compared with immediate CT was $7483 and $32,000 per scaphoid fracture detected, respectively. The ICER of week 2 radiographs-MRI was around $170,000. Day 3 bone scan, week 2 radiographs alone, week 2 radiographs-CT, and week 2 radiographs-bone scan strategy were dominated or extendedly dominated by MRI strategies. The results were generally robust in multiple sensitivity analyses. Immediate CT and MRI were the most cost-effective strategies for diagnosing suspected scaphoid fractures. Economic and Decision Analyses Level II. See Instructions for Authors for a complete description of levels of evidence.
NASA Astrophysics Data System (ADS)
Sun, A. Y.; Lu, J.; Hovorka, S. D.; Freifeld, B. M.; Islam, A.
2015-12-01
Monitoring techniques capable of deep subsurface detection are desirable for early warning and leakage pathway identification in geologic carbon storage formations. This work investigates the feasibility of a leakage detection technique based on pulse testing, which is a traditional hydrogeological characterization tool. In pulse testing, the monitoring reservoir is stimulated at a fixed frequency and the acquired pressure perturbation signals are analyzed in the frequency domain to detect potential deviations in the reservoir's frequency domain response function. Unlike traditional time-domain analyses, the frequency-domain analysis aims to minimize the interference of reservoir noise by imposing coded injection patterns such that the reservoir responses to injection can be uniquely determined. We have established the theoretical basis of the approach in previous work. Recently, field validation of this pressure-based, leakage detection technique was conducted at a CO2-EOR site located in Mississippi, USA. During the demonstration, two sets of experiments were performed using 90-min and 150-min pulsing periods, for both with and without leak scenarios. Because of the lack of pre-existing leakage pathways, artificial leakage CO2 was simulated by rate-controlled venting from one of the monitoring wells. Our results show that leakage events caused a significant deviation in the amplitude of the frequency response function, indicating that pulse testing may be used as a cost-effective monitoring technique with a strong potential for automation.
Rapid Detection of Infectious Envelope Proteins by Magnetoplasmonic Toroidal Metasensors.
Ahmadivand, Arash; Gerislioglu, Burak; Manickam, Pandiaraj; Kaushik, Ajeet; Bhansali, Shekhar; Nair, Madhavan; Pala, Nezih
2017-09-22
Unconventional characteristics of magnetic toroidal multipoles have triggered researchers to study these unique resonant phenomena by using both 3D and planar resonators under intense radiation. Here, going beyond conventional planar unit cells, we report on the observation of magnetic toroidal modes using artificially engineered multimetallic planar plasmonic resonators. The proposed microstructures consist of iron (Fe) and titanium (Ti) components acting as magnetic resonators and torus, respectively. Our numerical studies and following experimental verifications show that the proposed structures allow for excitation of toroidal dipoles in the terahertz (THz) domain with the experimental Q-factor of ∼18. Taking the advantage of high-Q toroidal line shape and its dependence on the environmental perturbations, we demonstrate that room-temperature toroidal metasurface is a reliable platform for immunosensing applications. As a proof of concept, we utilized our plasmonic metasurface to detect Zika-virus (ZIKV) envelope protein (with diameter of 40 nm) using a specific ZIKV antibody. The sharp toroidal resonant modes of the surface functionalized structures shift as a function of the ZIKV envelope protein for small concentrations (∼pM). The results of sensing experiments reveal rapid, accurate, and quantitative detection of envelope proteins with the limit of detection of ∼24.2 pg/mL and sensitivity of 6.47 GHz/log(pg/mL). We envision that the proposed toroidal metasurface opens new avenues for developing low-cost, and efficient THz plasmonic sensors for infection and targeted bioagent detection.
Xiong, Can; Zhang, Tengfei; Kong, Weiyu; Zhang, Zhixiang; Qu, Hao; Chen, Wei; Wang, Yanbo; Luo, Linbao; Zheng, Lei
2018-03-15
Biomarkers in tears have attracted much attention in daily healthcare sensing and monitoring. Here, highly sensitive sensors for simultaneous detection of glucose and uric acid are successfully constructed based on solution-gated graphene transistors (SGGTs) with two separate Au gate electrodes, modified with GOx-CHIT and BSA-CHIT respectively. The sensitivity of the SGGT is dramatically improved by co-modifying the Au gate with ZIF-67 derived porous Co 3 O 4 hollow nanopolyhedrons. The sensing mechanism for glucose sensor is attributed to the reaction of H 2 O 2 generated by the oxidation of glucose near the gate, while the sensing mechanism for uric acid is due to the direct electro-oxidation of uric acid molecules on the gate. The optimized glucose and uric acid sensors show the detection limits both down to 100nM, far beyond the sensitivity required for non-invasive detection of glucose and uric acid in tears. The glucose and uric acid in real tear samples was quantitatively detected at 323.2 ± 16.1μM and 98.5 ± 16.3μM by using the functionalized SGGT device. Due to the low-cost, high-biocompatibility and easy-fabrication features of the ZIF-67 derived porous Co 3 O 4 hollow nanopolyhedron, they provide excellent electrocatalytic nanomaterials for enhancing sensitivity of SGGTs for a broad range of disease-related biomarkers. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Li, Jun; Koehne, Jessica; Chen, Hua; Cassell, Alan; Ng, Hou Tee; Fan, Wendy; Ye, Qi; Han, Jie; Meyyappan, M.
2003-01-01
A reliable nanoelectrode array based on vertically aligned multi-walled carbon nanotubes (MWNTs) embedded in SiO2 is used for ultrasensitive DNA detection. Characteristic nanoelectrode behavior is observed using low-density MWNT arrays for measuring both bulk and surface immobilized redox species such as K4Fe(CN)6 and ferrocene derivatives. The open-end of MWNTs are found to present similar properties as graphite edge-plane electrodes with wide potential window, flexible chemical functionalities, and good biocompatibility. BRCA1 related oligonucleotide probes with 18 bp are selectively functionalized at the open ends of the nanotube array and specifically hybridized with oligonucleotide targets incorporated with a polyG tag. The guanine groups are employed as the signal moieties in the electrochemical measurements. R(bpy)(sup 2+, sub 3) mediator is used to further amplify the guanine oxidation signal. The hybridization of sub-attomoles of DNA targets is detected electrochemically by combining the MWNT nanoelectrode array with the R(bpy)(sup 2+, sub 3) amplification mechanism. This technique was employed for direct electrochemical detection of label-free PCR amplicon from a healthy donor through specific hybridization with the BRCA1 probe. The detection limit is estimated to be less than 1000 DNA molecules since abundant guanine bases in the PCR amplicon provides a large signal. This system provides a general platform for rapid molecular diagnostics in applications requiring ultrahigh sensitivity, high-degree of miniaturization, and simple sample preparation, and low-cost operation.
iCopyDAV: Integrated platform for copy number variations—Detection, annotation and visualization
Vogeti, Sriharsha
2018-01-01
Discovery of copy number variations (CNVs), a major category of structural variations, have dramatically changed our understanding of differences between individuals and provide an alternate paradigm for the genetic basis of human diseases. CNVs include both copy gain and copy loss events and their detection genome-wide is now possible using high-throughput, low-cost next generation sequencing (NGS) methods. However, accurate detection of CNVs from NGS data is not straightforward due to non-uniform coverage of reads resulting from various systemic biases. We have developed an integrated platform, iCopyDAV, to handle some of these issues in CNV detection in whole genome NGS data. It has a modular framework comprising five major modules: data pre-treatment, segmentation, variant calling, annotation and visualization. An important feature of iCopyDAV is the functional annotation module that enables the user to identify and prioritize CNVs encompassing various functional elements, genomic features and disease-associations. Parallelization of the segmentation algorithms makes the iCopyDAV platform even accessible on a desktop. Here we show the effect of sequencing coverage, read length, bin size, data pre-treatment and segmentation approaches on accurate detection of the complete spectrum of CNVs. Performance of iCopyDAV is evaluated on both simulated data and real data for different sequencing depths. It is an open-source integrated pipeline available at https://github.com/vogetihrsh/icopydav and as Docker’s image at http://bioinf.iiit.ac.in/icopydav/. PMID:29621297
DOE Office of Scientific and Technical Information (OSTI.GOV)
Granderson, G.D.
The purpose of the dissertation is to examine the impact of rate-of-return regulation on the cost of transporting natural gas in interstate commerce. Of particular interest is the effect of the regulation on the input choice of a firm. Does regulation induce a regulated firm to produce its selected level of output at greater than minimum cost The theoretical model is based on the work of Rolf Faere and James Logan who investigate the duality relationship between the cost and production functions of a rate-of-return regulated firm. Faere and Logan derive the cost function for a regulated firm as themore » minimum cost of producing the firm's selected level of output, subject to the regulatory constraint. The regulated cost function is used to recover the unregulated cost function. A firm's unregulated cost function is the minimum cost of producing its selected level of output. Characteristics of the production technology are obtained from duality between the production and unregulated cost functions. Using data on 20 pipeline companies from 1977 to 1987, the author estimates a random effects model that consists of a regulated cost function and its associated input share equations. The model is estimated as a set of seemingly unrelated regressions. The empirical results are used to test the Faere and Logan theory and the traditional Averch-Johnson hypothesis of overcapitalization. Parameter estimates are used to recover the unregulated cost function and to calculate the amount by which transportation costs are increased by the regulation of the industry. Empirical results show that a firm's transportation cost decreases as the allowed rate of return increases and the regulatory constraint becomes less tight. Elimination of the regulatory constraint would lead to a reduction in costs on average of 5.278%. There is evidence that firms overcapitalize on pipeline capital. There is inconclusive evidence on whether firms overcapitalized on compressor station capital.« less
NASA Astrophysics Data System (ADS)
Sjoeholm, K. R.
1981-02-01
The dual approach to the theory of production is used to estimate factor demand functions of the Swedish manufacturing industry. Two approximations of the cost function, the translog and the generalized Leontief models, are used. The price elasticities of the factor demand do not seem to depend on the choice of model. This is at least true as to the sign pattern and as to the inputs capital, labor, total energy and other materials. Total energy is separated into solid fuels, gasoline, fuel oil, electricity and a residual. Fuel oil and electricity are found to be substitutes by both models. Capital and energy are shown to be substitutes. This implies that Swedish industry will save more energy if the capital cost can be reduced. Both models are, in the best versions, able to detect an inappropriate variable. The assumption of perfect competition on the product market, is shown to be inadequate by both models. When this assumption is relaxed, the normal substitution pattern among the inputs is resumed.
Hubig, Michael; Suchandt, Steffen; Adam, Nico
2004-10-01
Phase unwrapping (PU) represents an important step in synthetic aperture radar interferometry (InSAR) and other interferometric applications. Among the different PU methods, the so called branch-cut approaches play an important role. In 1996 M. Costantini [Proceedings of the Fringe '96 Workshop ERS SAR Interferometry (European Space Agency, Munich, 1996), pp. 261-272] proposed to transform the problem of correctly placing branch cuts into a minimum cost flow (MCF) problem. The crucial point of this new approach is to generate cost functions that represent the a priori knowledge necessary for PU. Since cost functions are derived from measured data, they are random variables. This leads to the question of MCF solution stability: How much can the cost functions be varied without changing the cheapest flow that represents the correct branch cuts? This question is partially answered: The existence of a whole linear subspace in the space of cost functions is shown; this subspace contains all cost differences by which a cost function can be changed without changing the cost difference between any two flows that are discharging any residue configuration. These cost differences are called strictly stable cost differences. For quadrangular nonclosed networks (the most important type of MCF networks for interferometric purposes) a complete classification of strictly stable cost differences is presented. Further, the role of the well-known class of node potentials in the framework of strictly stable cost differences is investigated, and information on the vector-space structure representing the MCF environment is provided.
Video-based real-time on-street parking occupancy detection system
NASA Astrophysics Data System (ADS)
Bulan, Orhan; Loce, Robert P.; Wu, Wencheng; Wang, YaoRong; Bernal, Edgar A.; Fan, Zhigang
2013-10-01
Urban parking management is receiving significant attention due to its potential to reduce traffic congestion, fuel consumption, and emissions. Real-time parking occupancy detection is a critical component of on-street parking management systems, where occupancy information is relayed to drivers via smart phone apps, radio, Internet, on-road signs, or global positioning system auxiliary signals. Video-based parking occupancy detection systems can provide a cost-effective solution to the sensing task while providing additional functionality for traffic law enforcement and surveillance. We present a video-based on-street parking occupancy detection system that can operate in real time. Our system accounts for the inherent challenges that exist in on-street parking settings, including illumination changes, rain, shadows, occlusions, and camera motion. Our method utilizes several components from video processing and computer vision for motion detection, background subtraction, and vehicle detection. We also present three traffic law enforcement applications: parking angle violation detection, parking boundary violation detection, and exclusion zone violation detection, which can be integrated into the parking occupancy cameras as a value-added option. Our experimental results show that the proposed parking occupancy detection method performs in real-time at 5 frames/s and achieves better than 90% detection accuracy across several days of videos captured in a busy street block under various weather conditions such as sunny, cloudy, and rainy, among others.
A harmonic pulse testing method for leakage detection in deep subsurface storage formations
NASA Astrophysics Data System (ADS)
Sun, Alexander Y.; Lu, Jiemin; Hovorka, Susan
2015-06-01
Detection of leakage in deep geologic storage formations (e.g., carbon sequestration sites) is a challenging problem. This study investigates an easy-to-implement frequency domain leakage detection technology based on harmonic pulse testing (HPT). Unlike conventional constant-rate pressure interference tests, HPT stimulates a reservoir using periodic injection rates. The fundamental principle underlying HPT-based leakage detection is that leakage modifies a storage system's frequency response function, thus providing clues of system malfunction. During operations, routine HPTs can be conducted at multiple pulsing frequencies to obtain experimental frequency response functions, using which the possible time-lapse changes are examined. In this work, a set of analytical frequency response solutions is derived for predicting system responses with and without leaks for single-phase flow systems. Sensitivity studies show that HPT can effectively reveal the presence of leaks. A search procedure is then prescribed for locating the actual leaks using amplitude and phase information obtained from HPT, and the resulting optimization problem is solved using the genetic algorithm. For multiphase flows, the applicability of HPT-based leakage detection procedure is exemplified numerically using a carbon sequestration problem. Results show that the detection procedure is applicable if the average reservoir conditions in the testing zone stay relatively constant during the tests, which is a working assumption under many other interpretation methods for pressure interference tests. HPT is a cost-effective tool that only requires periodic modification of the nominal injection rate. Thus it can be incorporated into existing monitoring plans with little additional investment.
Pothole Detection System Using a Black-box Camera.
Jo, Youngtae; Ryu, Seungki
2015-11-19
Aging roads and poor road-maintenance systems result a large number of potholes, whose numbers increase over time. Potholes jeopardize road safety and transportation efficiency. Moreover, they are often a contributing factor to car accidents. To address the problems associated with potholes, the locations and size of potholes must be determined quickly. Sophisticated road-maintenance strategies can be developed using a pothole database, which requires a specific pothole-detection system that can collect pothole information at low cost and over a wide area. However, pothole repair has long relied on manual detection efforts. Recent automatic detection systems, such as those based on vibrations or laser scanning, are insufficient to detect potholes correctly and inexpensively owing to the unstable detection of vibration-based methods and high costs of laser scanning-based methods. Thus, in this paper, we introduce a new pothole-detection system using a commercial black-box camera. The proposed system detects potholes over a wide area and at low cost. We have developed a novel pothole-detection algorithm specifically designed to work with the embedded computing environments of black-box cameras. Experimental results are presented with our proposed system, showing that potholes can be detected accurately in real-time.
18 CFR 301.7 - Average System Cost methodology functionalization.
Code of Federal Regulations, 2010 CFR
2010-04-01
... SYSTEM COST METHODOLOGY FOR SALES FROM UTILITIES TO BONNEVILLE POWER ADMINISTRATION UNDER NORTHWEST POWER... functionalization under its Direct Analysis assigns costs, revenues, debits or credits based upon the actual and/or...) Functionalization methods. (1) Direct analysis, if allowed or required by Table 1, assigns costs, revenues, debits...
Optical biosensor system with integrated microfluidic sample preparation and TIRF based detection
NASA Astrophysics Data System (ADS)
Gilli, Eduard; Scheicher, Sylvia R.; Suppan, Michael; Pichler, Heinz; Rumpler, Markus; Satzinger, Valentin; Palfinger, Christian; Reil, Frank; Hajnsek, Martin; Köstler, Stefan
2013-05-01
There is a steadily growing demand for miniaturized bioanalytical devices allowing for on-site or point-of-care detection of biomolecules or pathogens in applications like diagnostics, food testing, or environmental monitoring. These, so called labs-on-a-chip or micro-total analysis systems (μ-TAS) should ideally enable convenient sample-in - result-out type operation. Therefore, the entire process from sample preparation, metering, reagent incubation, etc. to detection should be performed on a single disposable device (on-chip). In the early days such devices were mainly fabricated using glass or silicon substrates and adapting established fabrication technologies from the electronics and semiconductor industry. More recently, the development focuses on the use of thermoplastic polymers as they allow for low-cost high volume fabrication of disposables. One of the most promising materials for the development of plastic based lab-on-achip systems are cyclic olefin polymers and copolymers (COP/COC) due to their excellent optical properties (high transparency and low autofluorescence) and ease of processing. We present a bioanalytical system for whole blood samples comprising a disposable plastic chip based on TIRF (total internal reflection fluorescence) optical detection. The chips were fabricated by compression moulding of COP and microfluidic channels were structured by hot embossing. These microfluidic structures integrate several sample pretreatment steps. These are the separation of erythrocytes, metering of sample volume using passive valves, and reagent incubation for competitive bioassays. The surface of the following optical detection zone is functionalized with specific capture probes in an array format. The plastic chips comprise dedicated structures for simple and effective coupling of excitation light from low-cost laser diodes. This enables TIRF excitation of fluorescently labeled probes selectively bound to detection spots at the microchannel surface. The fluorescence of these detection arrays is imaged using a simple set-up based on a digital consumer camera. Image processing for spot detection and intensity calculation is accomplished using customized software. Using this combined TIRF excitation and imaging based detection approach allowes for effective suppression of background fluorescence from the sample, multiplexed detection in an array format, as well as internal calibration and background correction.
Can IR scene projectors reduce total system cost?
NASA Astrophysics Data System (ADS)
Ginn, Robert; Solomon, Steven
2006-05-01
There is an incredible amount of system engineering involved in turning the typical infrared system needs of probability of detection, probability of identification, and probability of false alarm into focal plane array (FPA) requirements of noise equivalent irradiance (NEI), modulation transfer function (MTF), fixed pattern noise (FPN), and defective pixels. Unfortunately, there are no analytic solutions to this problem so many approximations and plenty of "seat of the pants" engineering is employed. This leads to conservative specifications, which needlessly drive up system costs by increasing system engineering costs, reducing FPA yields, increasing test costs, increasing rework and the never ending renegotiation of requirements in an effort to rein in costs. These issues do not include the added complexity to the FPA factory manager of trying to meet varied, and changing, requirements for similar products because different customers have made different approximations and flown down different specifications. Scene generation technology may well be mature and cost effective enough to generate considerable overall savings for FPA based systems. We will compare the costs and capabilities of various existing scene generation systems and estimate the potential savings if implemented at several locations in the IR system fabrication cycle. The costs of implementing this new testing methodology will be compared to the probable savings in systems engineering, test, rework, yield improvement and others. The diverse requirements and techniques required for testing missile warning systems, missile seekers, and FLIRs will be defined. Last, we will discuss both the hardware and software requirements necessary to meet the new test paradigm and discuss additional cost improvements related to the incorporation of these technologies.
The Potential Return on Public Investment in Detecting Adverse Drug Effects.
Huybrechts, Krista F; Desai, Rishi J; Park, Moa; Gagne, Joshua J; Najafzadeh, Mehdi; Avorn, Jerry
2017-06-01
Many countries lack fully functional pharmacovigilance programs, and public budgets allocated to pharmacovigilance in industrialized countries remain low due to resource constraints and competing priorities. Using 3 case examples, we sought to estimate the public health and economic benefits resulting from public investment in active pharmacovigilance programs to detect adverse drug effects. We assessed 3 examples in which early signals of safety hazards were not adequately recognized, resulting in continued exposure of a large number of patients to these drugs when safer and effective alternative treatments were available. The drug examples studied were rofecoxib, cerivastatin, and troglitazone. Using an individual patient simulation model and the health care system perspective, we estimated the potential costs that could have been averted by early systematic detection of safety hazards through the implementation of active surveillance programs. We found that earlier drug withdrawal made possible by active safety surveillance would most likely have resulted in savings in direct medical costs of $773-$884 million for rofecoxib, $3-$10 million for cerivastatin, and $38-$63 million for troglitazone in the United States through the prevention of adverse events. By contrast, the yearly public investment in Food and Drug Administration initiated population-based pharmacovigilance activities in the United States is about $42.5 million at present. These examples illustrate a critical and economically justifiable role for active adverse effect surveillance in protecting the health of the public.
A tsunami early warning system for the coastal area modeling
NASA Astrophysics Data System (ADS)
Soebroto, Arief Andy; Sunaryo, Suhartanto, Ery
2015-04-01
The tsunami disaster is a potential disaster in the territory of Indonesia. Indonesia is an archipelago country and close to the ocean deep. The tsunami occurred in Aceh province in 2004. Early prevention efforts have been carried out. One of them is making "tsunami buoy" which has been developed by BPPT. The tool puts sensors on the ocean floor near the coast to detect earthquakes on the ocean floor. Detection results are transmitted via satellite by a transmitter placed floating on the sea surface. The tool will cost billions of dollars for each system. Another constraint was the transmitter theft "tsunami buoy" in the absence of guard. In this study of the system has a transmission system using radio frequency and focused on coastal areas where costs are cheaper, so that it can be applied at many beaches in Indonesia are potentially affected by the tsunami. The monitoring system sends the detection results to the warning system using a radio frequency with a capability within 3 Km. Test results on the sub module sensor monitoring system generates an error of 0.63% was taken 10% showed a good quality sensing. The test results of data transmission from the transceiver of monitoring system to the receiver of warning system produces 100% successful delivery and reception of data. The test results on the whole system to function 100% properly.
The Potential Return on Public Investment in Detecting Adverse Drug Effects
Huybrechts, Krista F.; Desai, Rishi J.; Park, Moa; Gagne, Joshua J.; Najafzadeh, Mehdi; Avorn, Jerry
2017-01-01
Background Many countries lack fully functional pharmacovigilance programs, and public budgets allocated to pharmacovigilance in industrialized countries remain low due to resource constraints and competing priorities. Objective Using 3 case examples, we sought to estimate the public health and economic benefits resulting from public investment in active pharmacovigilance programs to detect adverse drug effects. Research Design We assessed three examples in which early signals of safety hazards were not adequately recognized, resulting in continued exposure of a large number of patients to these drugs when safer and effective alternative treatments were available. The drug examples studied were rofecoxib, cerivastatin, and troglitazone. Using an individual patient simulation model and the healthcare system perspective, we estimated the potential costs that could have been averted by early systematic detection of safety hazards through the implementation of active surveillance programs. Results We found that earlier drug withdrawal made possible by active safety surveillance would most likely have resulted in savings in direct medical costs of $773 to $884 million for rofecoxib, $3 to $10 million for cerivastatin, and $38 to $63 million for troglitazone in the US through the prevention of adverse events. By contrast, the yearly public investment in FDA initiated population-based pharmacovigilance activities in the US is about $42.5 million at present. Conclusion These examples illustrate a critical and economically justifiable role for active adverse effect surveillance in protecting the health of the public. PMID:28505041
Myers, Jonathan S.; Henderer, Jeffrey; Crews, John E.; Saaddine, Jinan B.; Molineaux, Jeanne; Johnson, Deiana; Sembhi, Harjeet; Stratford, Shayla; Suleiman, Ayman; Pizzi, Laura; Spaeth, George L.; Katz, L. Jay
2016-01-01
Purpose The Wills Eye Glaucoma Research Center initiated a 2-year demonstration project to develop and implement a community-based intervention to improve detection and management of glaucoma in Philadelphia. Methods The glaucoma detection examination consisted of: ocular, medical, and family history; visual acuity testing; corneal pachymetry; biomicroscopy of the anterior segment; intraocular pressure (IOP) measurement; gonioscopy; funduscopy; automated visual field testing; and fundus-color photography. Treatment included laser surgery and/or IOP-lowering medication. A cost analysis was conducted to understand resource requirements. Outcome measures included; prevalence of glaucoma-related pathology and other eye diseases among high-risk populations; the impact of educational workshops on level of knowledge about glaucoma (assessed by pre- and post-test evaluation); and patient satisfaction of the glaucoma detection examinations in the community (assessed by satisfaction survey). Treatment outcome measures were change in IOP at 4–6 weeks and 4–6 months following selective laser trabeculoplasty treatment, deepening of the anterior chamber angle following laser-peripheral iridotomy treatment, and rate of adherence to recommended follow-up examinations. Cost outcomes included total program costs, cost per case of glaucoma detected, and cost per case of ocular disease detected. Results This project enrolled 1649 participants (African Americans aged 50+ years, adults 60+ years and individuals with a family history of glaucoma). A total of 1074 individuals attended a glaucoma educational workshop and 1508 scheduled glaucoma detection examination appointments in the community setting. Conclusions The Philadelphia Glaucoma Detection and Treatment Project aimed to improve access and use of eye care and to provide a model for a targeted community-based glaucoma program. PMID:26950056
Hark, Lisa; Waisbourd, Michael; Myers, Jonathan S; Henderer, Jeffrey; Crews, John E; Saaddine, Jinan B; Molineaux, Jeanne; Johnson, Deiana; Sembhi, Harjeet; Stratford, Shayla; Suleiman, Ayman; Pizzi, Laura; Spaeth, George L; Katz, L Jay
2016-01-01
The Wills Eye Glaucoma Research Center initiated a 2-year demonstration project to develop and implement a community-based intervention to improve detection and management of glaucoma in Philadelphia. The glaucoma detection examination consisted of: ocular, medical, and family history; visual acuity testing; corneal pachymetry; biomicroscopy of the anterior segment; intraocular pressure (IOP) measurement; gonioscopy; funduscopy; automated visual field testing; and fundus-color photography. Treatment included laser surgery and/or IOP-lowering medication. A cost analysis was conducted to understand resource requirements. Outcome measures included; prevalence of glaucoma-related pathology and other eye diseases among high-risk populations; the impact of educational workshops on level of knowledge about glaucoma (assessed by pre- and post-test evaluation); and patient satisfaction of the glaucoma detection examinations in the community (assessed by satisfaction survey). Treatment outcome measures were change in IOP at 4-6 weeks and 4-6 months following selective laser trabeculoplasty treatment, deepening of the anterior chamber angle following laser-peripheral iridotomy treatment, and rate of adherence to recommended follow-up examinations. Cost outcomes included total program costs, cost per case of glaucoma detected, and cost per case of ocular disease detected. This project enrolled 1649 participants (African Americans aged 50+ years, adults 60+ years and individuals with a family history of glaucoma). A total of 1074 individuals attended a glaucoma educational workshop and 1508 scheduled glaucoma detection examination appointments in the community setting. The Philadelphia Glaucoma Detection and Treatment Project aimed to improve access and use of eye care and to provide a model for a targeted community-based glaucoma program.
Fast and accurate spectral estimation for online detection of partial broken bar in induction motors
NASA Astrophysics Data System (ADS)
Samanta, Anik Kumar; Naha, Arunava; Routray, Aurobinda; Deb, Alok Kanti
2018-01-01
In this paper, an online and real-time system is presented for detecting partial broken rotor bar (BRB) of inverter-fed squirrel cage induction motors under light load condition. This system with minor modifications can detect any fault that affects the stator current. A fast and accurate spectral estimator based on the theory of Rayleigh quotient is proposed for detecting the spectral signature of BRB. The proposed spectral estimator can precisely determine the relative amplitude of fault sidebands and has low complexity compared to available high-resolution subspace-based spectral estimators. Detection of low-amplitude fault components has been improved by removing the high-amplitude fundamental frequency using an extended-Kalman based signal conditioner. Slip is estimated from the stator current spectrum for accurate localization of the fault component. Complexity and cost of sensors are minimal as only a single-phase stator current is required. The hardware implementation has been carried out on an Intel i7 based embedded target ported through the Simulink Real-Time. Evaluation of threshold and detectability of faults with different conditions of load and fault severity are carried out with empirical cumulative distribution function.
Bao, Xu; Li, Haijian; Xu, Dongwei; Jia, Limin; Ran, Bin; Rong, Jian
2016-11-06
The jam flow condition is one of the main traffic states in traffic flow theory and the most difficult state for sectional traffic information acquisition. Since traffic information acquisition is the basis for the application of an intelligent transportation system, research on traffic vehicle counting methods for the jam flow conditions has been worthwhile. A low-cost and energy-efficient type of multi-function wireless traffic magnetic sensor was designed and developed. Several advantages of the traffic magnetic sensor are that it is suitable for large-scale deployment and time-sustainable detection for traffic information acquisition. Based on the traffic magnetic sensor, a basic vehicle detection algorithm (DWVDA) with less computational complexity was introduced for vehicle counting in low traffic volume conditions. To improve the detection performance in jam flow conditions with a "tailgating effect" between front vehicles and rear vehicles, an improved vehicle detection algorithm (SA-DWVDA) was proposed and applied in field traffic environments. By deploying traffic magnetic sensor nodes in field traffic scenarios, two field experiments were conducted to test and verify the DWVDA and the SA-DWVDA algorithms. The experimental results have shown that both DWVDA and the SA-DWVDA algorithms yield a satisfactory performance in low traffic volume conditions (scenario I) and both of their mean absolute percent errors are less than 1% in this scenario. However, for jam flow conditions with heavy traffic volumes (scenario II), the SA-DWVDA was proven to achieve better results, and the mean absolute percent error of the SA-DWVDA is 2.54% with corresponding results of the DWVDA 7.07%. The results conclude that the proposed SA-DWVDA can implement efficient and accurate vehicle detection in jam flow conditions and can be employed in field traffic environments.
Cheng, Ji-Hong; Liu, Wen-Chun; Chang, Ting-Tsung; Hsieh, Sun-Yuan; Tseng, Vincent S
2017-10-01
Many studies have suggested that deletions of Hepatitis B Viral (HBV) are associated with the development of progressive liver diseases, even ultimately resulting in hepatocellular carcinoma (HCC). Among the methods for detecting deletions from next-generation sequencing (NGS) data, few methods considered the characteristics of virus, such as high evolution rates and high divergence among the different HBV genomes. Sequencing high divergence HBV genome sequences using the NGS technology outputs millions of reads. Thus, detecting exact breakpoints of deletions from these big and complex data incurs very high computational cost. We proposed a novel analytical method named VirDelect (Virus Deletion Detect), which uses split read alignment base to detect exact breakpoint and diversity variable to consider high divergence in single-end reads data, such that the computational cost can be reduced without losing accuracy. We use four simulated reads datasets and two real pair-end reads datasets of HBV genome sequence to verify VirDelect accuracy by score functions. The experimental results show that VirDelect outperforms the state-of-the-art method Pindel in terms of accuracy score for all simulated datasets and VirDelect had only two base errors even in real datasets. VirDelect is also shown to deliver high accuracy in analyzing the single-end read data as well as pair-end data. VirDelect can serve as an effective and efficient bioinformatics tool for physiologists with high accuracy and efficient performance and applicable to further analysis with characteristics similar to HBV on genome length and high divergence. The software program of VirDelect can be downloaded at https://sourceforge.net/projects/virdelect/. Copyright © 2017. Published by Elsevier Inc.
Bao, Xu; Li, Haijian; Xu, Dongwei; Jia, Limin; Ran, Bin; Rong, Jian
2016-01-01
The jam flow condition is one of the main traffic states in traffic flow theory and the most difficult state for sectional traffic information acquisition. Since traffic information acquisition is the basis for the application of an intelligent transportation system, research on traffic vehicle counting methods for the jam flow conditions has been worthwhile. A low-cost and energy-efficient type of multi-function wireless traffic magnetic sensor was designed and developed. Several advantages of the traffic magnetic sensor are that it is suitable for large-scale deployment and time-sustainable detection for traffic information acquisition. Based on the traffic magnetic sensor, a basic vehicle detection algorithm (DWVDA) with less computational complexity was introduced for vehicle counting in low traffic volume conditions. To improve the detection performance in jam flow conditions with a “tailgating effect” between front vehicles and rear vehicles, an improved vehicle detection algorithm (SA-DWVDA) was proposed and applied in field traffic environments. By deploying traffic magnetic sensor nodes in field traffic scenarios, two field experiments were conducted to test and verify the DWVDA and the SA-DWVDA algorithms. The experimental results have shown that both DWVDA and the SA-DWVDA algorithms yield a satisfactory performance in low traffic volume conditions (scenario I) and both of their mean absolute percent errors are less than 1% in this scenario. However, for jam flow conditions with heavy traffic volumes (scenario II), the SA-DWVDA was proven to achieve better results, and the mean absolute percent error of the SA-DWVDA is 2.54% with corresponding results of the DWVDA 7.07%. The results conclude that the proposed SA-DWVDA can implement efficient and accurate vehicle detection in jam flow conditions and can be employed in field traffic environments. PMID:27827974
Sergeyeva, T A; Gorbach, L A; Piletska, E V; Piletsky, S A; Brovko, O O; Honcharova, L A; Lutsyk, O D; Sergeeva, L M; Zinchenko, O A; El'skaya, A V
2013-04-03
An easy-to-use colorimetric test-system for the efficient detection of creatinine in aqueous samples was developed. The test-system is based on composite molecularly imprinted polymer (MIP) membranes with artificial receptor sites capable of creatinine recognition. A thin MIP layer was created on the surface of microfiltration polyvinylidene fluoride (PVDF) membranes using method of photo-initiated grafting polymerization. The MIP layer was obtained by co-polymerization of a functional monomer (e.g. 2-acrylamido-2-methyl-1-propanesulfonic acid, itaconic acid or methacrylic acid) with N, N'-methylenebisacrylamide as a cross-linker. The choice of the functional monomer was based on the results of computational modeling. The creatinine-selective composite MIP membranes were used for measuring creatinine in aqueous samples. Creatinine molecules were selectively adsorbed by the MIP membranes and quantified using color reaction with picrates. The intensity of MIP membranes staining was proportional to creatinine concentration in an analyzed sample. The colorimetric test-system based on the composite MIP membranes was characterized with 0.25 mM detection limit and 0.25-2.5mM linear dynamic range. Storage stability of the MIP membranes was estimated as at least 1 year at room temperature. As compared to the traditional methods of creatinine detection the developed test-system is characterized by simplicity of operation, small size and low cost. Copyright © 2013 Elsevier B.V. All rights reserved.
Stereo-vision-based terrain mapping for off-road autonomous navigation
NASA Astrophysics Data System (ADS)
Rankin, Arturo L.; Huertas, Andres; Matthies, Larry H.
2009-05-01
Successful off-road autonomous navigation by an unmanned ground vehicle (UGV) requires reliable perception and representation of natural terrain. While perception algorithms are used to detect driving hazards, terrain mapping algorithms are used to represent the detected hazards in a world model a UGV can use to plan safe paths. There are two primary ways to detect driving hazards with perception sensors mounted to a UGV: binary obstacle detection and traversability cost analysis. Binary obstacle detectors label terrain as either traversable or non-traversable, whereas, traversability cost analysis assigns a cost to driving over a discrete patch of terrain. In uncluttered environments where the non-obstacle terrain is equally traversable, binary obstacle detection is sufficient. However, in cluttered environments, some form of traversability cost analysis is necessary. The Jet Propulsion Laboratory (JPL) has explored both approaches using stereo vision systems. A set of binary detectors has been implemented that detect positive obstacles, negative obstacles, tree trunks, tree lines, excessive slope, low overhangs, and water bodies. A compact terrain map is built from each frame of stereo images. The mapping algorithm labels cells that contain obstacles as nogo regions, and encodes terrain elevation, terrain classification, terrain roughness, traversability cost, and a confidence value. The single frame maps are merged into a world map where temporal filtering is applied. In previous papers, we have described our perception algorithms that perform binary obstacle detection. In this paper, we summarize the terrain mapping capabilities that JPL has implemented during several UGV programs over the last decade and discuss some challenges to building terrain maps with stereo range data.
Stereo Vision Based Terrain Mapping for Off-Road Autonomous Navigation
NASA Technical Reports Server (NTRS)
Rankin, Arturo L.; Huertas, Andres; Matthies, Larry H.
2009-01-01
Successful off-road autonomous navigation by an unmanned ground vehicle (UGV) requires reliable perception and representation of natural terrain. While perception algorithms are used to detect driving hazards, terrain mapping algorithms are used to represent the detected hazards in a world model a UGV can use to plan safe paths. There are two primary ways to detect driving hazards with perception sensors mounted to a UGV: binary obstacle detection and traversability cost analysis. Binary obstacle detectors label terrain as either traversable or non-traversable, whereas, traversability cost analysis assigns a cost to driving over a discrete patch of terrain. In uncluttered environments where the non-obstacle terrain is equally traversable, binary obstacle detection is sufficient. However, in cluttered environments, some form of traversability cost analysis is necessary. The Jet Propulsion Laboratory (JPL) has explored both approaches using stereo vision systems. A set of binary detectors has been implemented that detect positive obstacles, negative obstacles, tree trunks, tree lines, excessive slope, low overhangs, and water bodies. A compact terrain map is built from each frame of stereo images. The mapping algorithm labels cells that contain obstacles as no-go regions, and encodes terrain elevation, terrain classification, terrain roughness, traversability cost, and a confidence value. The single frame maps are merged into a world map where temporal filtering is applied. In previous papers, we have described our perception algorithms that perform binary obstacle detection. In this paper, we summarize the terrain mapping capabilities that JPL has implemented during several UGV programs over the last decade and discuss some challenges to building terrain maps with stereo range data.
Wong, Martin C S; Ching, Jessica Y L; Chan, Victor C W; Sung, Joseph J Y
2015-09-04
Faecal immunochemical tests (FITs) and colonoscopy are two common screening tools for colorectal cancer(CRC). Most cost-effectiveness studies focused on survival as the outcome, and were based on modeling techniques instead of real world observational data. This study evaluated the cost-effectiveness of these two tests to detect colorectal neoplastic lesions based on data from a 5-year community screening service. The incremental cost-effectiveness ratio (ICER) was assessed based on the detection rates of neoplastic lesions, and costs including screening compliance, polypectomy, colonoscopy complications, and staging of CRC detected. A total of 5,863 patients received yearly FIT and 4,869 received colonoscopy. Compared with FIT, colonoscopy detected notably more adenomas (23.6% vs. 1.6%) and advanced lesions or cancer (4.2% vs. 1.2%). Using FIT as control, the ICER of screening colonoscopy in detecting adenoma, advanced adenoma, CRC and a composite endpoint of either advanced adenoma or stage I CRC was US$3,489, US$27,962, US$922,762 and US$23,981 respectively. The respective ICER was US$3,597, US$439,513, -US$2,765,876 and US$32,297 among lower-risk subjects; whilst the corresponding figure was US$3,153, US$14,852, US$184,162 and US$13,919 among higher-risk subjects. When compared to FIT, colonoscopy is considered cost-effective for screening adenoma, advanced neoplasia, and a composite endpoint of advanced neoplasia or stage I CRC.
Wong, Martin CS; Ching, Jessica YL; Chan, Victor CW; Sung, Joseph JY
2015-01-01
Faecal immunochemical tests (FITs) and colonoscopy are two common screening tools for colorectal cancer(CRC). Most cost-effectiveness studies focused on survival as the outcome, and were based on modeling techniques instead of real world observational data. This study evaluated the cost-effectiveness of these two tests to detect colorectal neoplastic lesions based on data from a 5-year community screening service. The incremental cost-effectiveness ratio (ICER) was assessed based on the detection rates of neoplastic lesions, and costs including screening compliance, polypectomy, colonoscopy complications, and staging of CRC detected. A total of 5,863 patients received yearly FIT and 4,869 received colonoscopy. Compared with FIT, colonoscopy detected notably more adenomas (23.6% vs. 1.6%) and advanced lesions or cancer (4.2% vs. 1.2%). Using FIT as control, the ICER of screening colonoscopy in detecting adenoma, advanced adenoma, CRC and a composite endpoint of either advanced adenoma or stage I CRC was US$3,489, US$27,962, US$922,762 and US$23,981 respectively. The respective ICER was US$3,597, US$439,513, -US$2,765,876 and US$32,297 among lower-risk subjects; whilst the corresponding figure was US$3,153, US$14,852, US$184,162 and US$13,919 among higher-risk subjects. When compared to FIT, colonoscopy is considered cost-effective for screening adenoma, advanced neoplasia, and a composite endpoint of advanced neoplasia or stage I CRC. PMID:26338314
NASA Astrophysics Data System (ADS)
Zhu, Wenlong; Ma, Shoufeng; Tian, Junfang; Li, Geng
2016-11-01
Travelers' route adjustment behaviors in a congested road traffic network are acknowledged as a dynamic game process between them. Existing Proportional-Switch Adjustment Process (PSAP) models have been extensively investigated to characterize travelers' route choice behaviors; PSAP has concise structure and intuitive behavior rule. Unfortunately most of which have some limitations, i.e., the flow over adjustment problem for the discrete PSAP model, the absolute cost differences route adjustment problem, etc. This paper proposes a relative-Proportion-based Route Adjustment Process (rePRAP) maintains the advantages of PSAP and overcomes these limitations. The rePRAP describes the situation that travelers on higher cost route switch to those with lower cost at the rate that is unilaterally depended on the relative cost differences between higher cost route and its alternatives. It is verified to be consistent with the principle of the rational behavior adjustment process. The equivalence among user equilibrium, stationary path flow pattern and stationary link flow pattern is established, which can be applied to judge whether a given network traffic flow has reached UE or not by detecting the stationary or non-stationary state of link flow pattern. The stability theorem is proved by the Lyapunov function approach. A simple example is tested to demonstrate the effectiveness of the rePRAP model.
Doshi, Shivang; Ray, David; Stein, Karen; Zhang, Jie; Koduru, Prasad; Fogt, Franz; Wellman, Axel; Wat, Ricky; Mathews, Charles
2016-01-06
Identification of alterations in ALK gene and development of ALK-directed therapies have increased the need for accurate and efficient detection methodologies. To date, research has focused on the concordance between the two most commonly used technologies, fluorescent in situ hybridization (FISH) and immunohistochemistry (IHC). However, inter-test concordance reflects only one, albeit important, aspect of the diagnostic process; laboratories, hospitals, and payors must understand the cost and workflow of ALK rearrangement detection strategies. Through literature review combined with interviews of pathologists and laboratory directors in the U.S. and Europe, a cost-impact model was developed that compared four alternative testing strategies-IHC only, FISH only, IHC pre-screen followed by FISH confirmation, and parallel testing by both IHC and FISH. Interviews were focused on costs of reagents, consumables, equipment, and personnel. The resulting model showed that testing by IHC alone cost less ($90.07 in the U.S., $68.69 in Europe) than either independent or parallel testing by both FISH and IHC ($441.85 in the U.S. and $279.46 in Europe). The strategies differed in cost of execution, turnaround time, reimbursement, and number of positive results detected, suggesting that laboratories must weigh the costs and the clinical benefit of available ALK testing strategies.
Doshi, Shivang; Ray, David; Stein, Karen; Zhang, Jie; Koduru, Prasad; Fogt, Franz; Wellman, Axel; Wat, Ricky; Mathews, Charles
2016-01-01
Identification of alterations in ALK gene and development of ALK-directed therapies have increased the need for accurate and efficient detection methodologies. To date, research has focused on the concordance between the two most commonly used technologies, fluorescent in situ hybridization (FISH) and immunohistochemistry (IHC). However, inter-test concordance reflects only one, albeit important, aspect of the diagnostic process; laboratories, hospitals, and payors must understand the cost and workflow of ALK rearrangement detection strategies. Through literature review combined with interviews of pathologists and laboratory directors in the U.S. and Europe, a cost-impact model was developed that compared four alternative testing strategies—IHC only, FISH only, IHC pre-screen followed by FISH confirmation, and parallel testing by both IHC and FISH. Interviews were focused on costs of reagents, consumables, equipment, and personnel. The resulting model showed that testing by IHC alone cost less ($90.07 in the U.S., $68.69 in Europe) than either independent or parallel testing by both FISH and IHC ($441.85 in the U.S. and $279.46 in Europe). The strategies differed in cost of execution, turnaround time, reimbursement, and number of positive results detected, suggesting that laboratories must weigh the costs and the clinical benefit of available ALK testing strategies. PMID:26838801
Cieza, Alarcos; Baldwin, David S.
2017-01-01
Development of payment systems for mental health services has been hindered by limited evidence for the utility of diagnosis or symptoms in predicting costs of care. We investigated the utility of functioning information in predicting costs for patients with mood and anxiety disorders. This was a prospective cohort study involving 102 adult patients attending a tertiary referral specialist clinic for mood and anxiety disorders. The main outcome was total costs, calculated by applying unit costs to healthcare use data. After adjusting for covariates, a significant total costs association was yielded for functioning (eβ=1.02; 95% confidence interval: 1.01–1.03), but not depressive symptom severity or anxiety symptom severity. When we accounted for the correlations between the main independent variables by constructing an abridged functioning metric, a significant total costs association was again yielded for functioning (eβ=1.04; 95% confidence interval: 1.01–1.09), but not symptom severity. The utility of functioning in predicting costs for patients with mood and anxiety disorders was supported. Functioning information could be useful within mental health payment systems. PMID:28383309
Relationship between functional disability and costs one and two years post stroke
Lekander, Ingrid; Willers, Carl; von Euler, Mia; Lilja, Mikael; Sunnerhagen, Katharina S.; Pessah-Rasmussen, Hélène; Borgström, Fredrik
2017-01-01
Background and purpose Stroke affects mortality, functional ability, quality of life and incurs costs. The primary objective of this study was to estimate the costs of stroke care in Sweden by level of disability and stroke type (ischemic (IS) or hemorrhagic stroke (ICH)). Method Resource use during first and second year following a stroke was estimated based on a research database containing linked data from several registries. Costs were estimated for the acute and post-acute management of stroke, including direct (health care consumption and municipal services) and indirect (productivity losses) costs. Resources and costs were estimated per stroke type and functional disability categorised by Modified Rankin Scale (mRS). Results The results indicated that the average costs per patient following a stroke were 350,000SEK/€37,000–480,000SEK/€50,000, dependent on stroke type and whether it was the first or second year post stroke. Large variations were identified between different subgroups of functional disability and stroke type, ranging from annual costs of 100,000SEK/€10,000–1,100,000SEK/€120,000 per patient, with higher costs for patients with ICH compared to IS and increasing costs with more severe functional disability. Conclusion Functional outcome is a major determinant on costs of stroke care. The stroke type associated with worse outcome (ICH) was also consistently associated to higher costs. Measures to improve function are not only important to individual patients and their family but may also decrease the societal burden of stroke. PMID:28384164
18 CFR 11.12 - Determination of section 10(f) costs.
Code of Federal Regulations, 2010 CFR
2010-04-01
... costs of the project. (2) If power is not an authorized function of the headwater project, the section... costs designated as the joint-use power cost, derived by deeming a power function at the project. The value of the benefits assigned to the deemed power function, for purposes of determining the value of...
18 CFR 11.12 - Determination of section 10(f) costs.
Code of Federal Regulations, 2012 CFR
2012-04-01
... costs of the project. (2) If power is not an authorized function of the headwater project, the section... costs designated as the joint-use power cost, derived by deeming a power function at the project. The value of the benefits assigned to the deemed power function, for purposes of determining the value of...
18 CFR 11.12 - Determination of section 10(f) costs.
Code of Federal Regulations, 2011 CFR
2011-04-01
... costs of the project. (2) If power is not an authorized function of the headwater project, the section... costs designated as the joint-use power cost, derived by deeming a power function at the project. The value of the benefits assigned to the deemed power function, for purposes of determining the value of...
18 CFR 11.12 - Determination of section 10(f) costs.
Code of Federal Regulations, 2014 CFR
2014-04-01
... costs of the project. (2) If power is not an authorized function of the headwater project, the section... costs designated as the joint-use power cost, derived by deeming a power function at the project. The value of the benefits assigned to the deemed power function, for purposes of determining the value of...
18 CFR 11.12 - Determination of section 10(f) costs.
Code of Federal Regulations, 2013 CFR
2013-04-01
... costs of the project. (2) If power is not an authorized function of the headwater project, the section... costs designated as the joint-use power cost, derived by deeming a power function at the project. The value of the benefits assigned to the deemed power function, for purposes of determining the value of...
Development of Activity-based Cost Functions for Cellulase, Invertase, and Other Enzymes
NASA Astrophysics Data System (ADS)
Stowers, Chris C.; Ferguson, Elizabeth M.; Tanner, Robert D.
As enzyme chemistry plays an increasingly important role in the chemical industry, cost analysis of these enzymes becomes a necessity. In this paper, we examine the aspects that affect the cost of enzymes based upon enzyme activity. The basis for this study stems from a previously developed objective function that quantifies the tradeoffs in enzyme purification via the foam fractionation process (Cherry et al., Braz J Chem Eng 17:233-238, 2000). A generalized cost function is developed from our results that could be used to aid in both industrial and lab scale chemical processing. The generalized cost function shows several nonobvious results that could lead to significant savings. Additionally, the parameters involved in the operation and scaling up of enzyme processing could be optimized to minimize costs. We show that there are typically three regimes in the enzyme cost analysis function: the low activity prelinear region, the moderate activity linear region, and high activity power-law region. The overall form of the cost analysis function appears to robustly fit the power law form.
Design and development of a microfluidic platform for use with colorimetric gold nanoprobe assays
NASA Astrophysics Data System (ADS)
Bernacka-Wojcik, Iwona
Due to the importance and wide applications of the DNA analysis, there is a need to make genetic analysis more available and more affordable. As such, the aim of this PhD thesis is to optimize a colorimetric DNA biosensor based on gold nanoprobes developed in CEMOP by reducing its price and the needed volume of solution without compromising the device sensitivity and reliability, towards the point of care use. Firstly, the price of the biosensor was decreased by replacing the silicon photodetector by a low cost, solution processed TiO2 photodetector. To further reduce the photodetector price, a novel fabrication method was developed: a cost-effective inkjet printing technology that enabled to increase TiO2 surface area. Secondly, the DNA biosensor was optimized by means of microfluidics that offer advantages of miniaturization, much lower sample/reagents consumption, enhanced system performance and functionality by integrating different components. In the developed microfluidic platform, the optical path length was extended by detecting along the channel and the light was transmitted by optical fibres enabling to guide the light very close to the analysed solution. Microfluidic chip of high aspect ratio ( 13), smooth and nearly vertical sidewalls was fabricated in PDMS using a SU-8 mould for patterning. The platform coupled to the gold nanoprobe assay enabled detection of Mycobacterium tuberculosis using 3 mul on DNA solution, i.e. 20 times less than in the previous state-of-the-art. Subsequently, the bio-microfluidic platform was optimized in terms of cost, electrical signal processing and sensitivity to colour variation, yielding 160% improvement of colorimetric AuNPs analysis. Planar microlenses were incorporated to converge light into the sample and then to the output fibre core increasing 6 times the signal-to-losses ratio. The optimized platform enabled detection of single nucleotide polymorphism related with obesity risk (FTO) using target DNA concentration below the limit of detection of the conventionally used microplate reader (i.e. 15 ng/mul) with 10 times lower solution volume (3 mul). The combination of the unique optical properties of gold nanoprobes with microfluidic platform resulted in sensitive and accurate sensor for single nucleotide polymorphism detection operating using small volumes of solutions and without the need for substrate functionalization or sophisticated instrumentation. Simultaneously, to enable on chip reagents mixing, a PDMS micromixer was developed and optimized for the highest efficiency, low pressure drop and short mixing length. The optimized device shows 80% of mixing efficiency at Re = 0.1 in 2.5 mm long mixer with the pressure drop of 6 Pa, satisfying requirements for the application in the microfluidic platform for DNA analysis.
Ramos, Enrique; Levinson, Benjamin T; Chasnoff, Sara; Hughes, Andrew; Young, Andrew L; Thornton, Katherine; Li, Allie; Vallania, Francesco L M; Province, Michael; Druley, Todd E
2012-12-06
Rare genetic variation in the human population is a major source of pathophysiological variability and has been implicated in a host of complex phenotypes and diseases. Finding disease-related genes harboring disparate functional rare variants requires sequencing of many individuals across many genomic regions and comparing against unaffected cohorts. However, despite persistent declines in sequencing costs, population-based rare variant detection across large genomic target regions remains cost prohibitive for most investigators. In addition, DNA samples are often precious and hybridization methods typically require large amounts of input DNA. Pooled sample DNA sequencing is a cost and time-efficient strategy for surveying populations of individuals for rare variants. We set out to 1) create a scalable, multiplexing method for custom capture with or without individual DNA indexing that was amenable to low amounts of input DNA and 2) expand the functionality of the SPLINTER algorithm for calling substitutions, insertions and deletions across either candidate genes or the entire exome by integrating the variant calling algorithm with the dynamic programming aligner, Novoalign. We report methodology for pooled hybridization capture with pre-enrichment, indexed multiplexing of up to 48 individuals or non-indexed pooled sequencing of up to 92 individuals with as little as 70 ng of DNA per person. Modified solid phase reversible immobilization bead purification strategies enable no sample transfers from sonication in 96-well plates through adapter ligation, resulting in 50% less library preparation reagent consumption. Custom Y-shaped adapters containing novel 7 base pair index sequences with a Hamming distance of ≥2 were directly ligated onto fragmented source DNA eliminating the need for PCR to incorporate indexes, and was followed by a custom blocking strategy using a single oligonucleotide regardless of index sequence. These results were obtained aligning raw reads against the entire genome using Novoalign followed by variant calling of non-indexed pools using SPLINTER or SAMtools for indexed samples. With these pipelines, we find sensitivity and specificity of 99.4% and 99.7% for pooled exome sequencing. Sensitivity, and to a lesser degree specificity, proved to be a function of coverage. For rare variants (≤2% minor allele frequency), we achieved sensitivity and specificity of ≥94.9% and ≥99.99% for custom capture of 2.5 Mb in multiplexed libraries of 22-48 individuals with only ≥5-fold coverage/chromosome, but these parameters improved to ≥98.7 and 100% with 20-fold coverage/chromosome. This highly scalable methodology enables accurate rare variant detection, with or without individual DNA sample indexing, while reducing the amount of required source DNA and total costs through less hybridization reagent consumption, multi-sample sonication in a standard PCR plate, multiplexed pre-enrichment pooling with a single hybridization and lesser sequencing coverage required to obtain high sensitivity.
Onesto, V; Villani, M; Coluccio, M L; Majewska, R; Alabastri, A; Battista, E; Schirato, A; Calestani, D; Coppedé, N; Cesarelli, M; Amato, F; Di Fabrizio, E; Gentile, F
2018-04-10
Diatom shells are a natural, theoretically unlimited material composed of silicon dioxide, with regular patterns of pores penetrating through their surface. For their characteristics, diatom shells show promise to be used as low cost, highly efficient drug carriers, sensor devices or other micro-devices. Here, we demonstrate diatom shells functionalized with gold nanoparticles for the harvesting and detection of biological analytes (bovine serum albumin-BSA) and chemical pollutants (mineral oil) in low abundance ranges, for applications in bioengineering, medicine, safety, and pollution monitoring.
Beyond bricks and mortar: recent research on substance use disorder recovery management.
Dennis, Michael L; Scott, Christy K; Laudet, Alexandre
2014-04-01
Scientific advances in the past 15 years have clearly highlighted the need for recovery management approaches to help individuals sustain recovery from chronic substance use disorders. This article reviews some of the recent findings related to recovery management: (1) continuing care, (2) recovery management checkups, (3) 12-step or mutual aid, and (4) technology-based interventions. The core assumption underlying these approaches is that earlier detection and re-intervention will improve long-term outcomes by minimizing the harmful consequences of the condition and maximizing or promoting opportunities for maintaining healthy levels of functioning in related life domains. Economic analysis is important because it can take a year or longer for such interventions to offset their costs. The article also examines the potential of smartphones and other recent technological developments to facilitate more cost-effective recovery management options.
Cost of Services Provided by the National Breast and Cervical Cancer Early Detection Program
Ekwueme, Donatus U.; Subramanian, Sujha; Trogdon, Justin G.; Miller, Jacqueline W.; Royalty, Janet E.; Li, Chunyu; Guy, Gery P.; Crouse, Wesley; Thompson, Hope; Gardner, James G.
2015-01-01
BACKGROUND The National Breast and Cervical Cancer Early Detection Program (NBCCEDP) is the largest cancer screening program for low-income women in the United States. This study updates previous estimates of the costs of delivering preventive cancer screening services in the NBCCEDP. METHODS We developed a standardized web-based cost-assessment tool to collect annual activity-based cost data on screening for breast and cervical cancer in the NBCCEDP. Data were collected from 63 of the 66 programs that received funding from the Centers for Disease Control and Prevention during the 2006/2007 fiscal year. We used these data to calculate costs of delivering preventive public health services in the program. RESULTS We estimated the total cost of all NBCCEDP services to be $296 (standard deviation [SD], $123) per woman served (including the estimated value of in-kind donations, which constituted approximately 15% of this total estimated cost). The estimated cost of screening and diagnostic services was $145 (SD, $38) per women served, which represented 57.7% of the total cost excluding the value of in-kind donations. Including the value of in-kind donations, the weighted mean cost of screening a woman for breast cancer was $110 with an office visit and $88 without, the weighted mean cost of a diagnostic procedure was $401, and the weighted mean cost per breast cancer detected was $35,480. For cervical cancer, the corresponding cost estimates were $61, $21, $415, and $18,995, respectively. CONCLUSIONS These NBCCEDP cost estimates may help policy makers in planning and implementing future costs for various potential changes to the program. PMID:25099904
Costs of early detection systems for epidemic malaria in highland areas of Kenya and Uganda
Mueller, Dirk H; Abeku, Tarekegn A; Okia, Michael; Rapuoda, Beth; Cox, Jonathan
2009-01-01
Background Malaria epidemics cause substantial morbidity and mortality in highland areas of Africa. The costs of detecting and controlling these epidemics have not been explored adequately in the past. This study presents the costs of establishing and running an early detection system (EDS) for epidemic malaria in four districts in the highlands of Kenya and Uganda. Methods An economic costing was carried out from the health service provider's perspective in both countries. Staff time for data entry and processing, as well as supervising and coordinating EDS activities at district and national levels was recorded and associated opportunity costs estimated. A threshold analysis was carried out to determine the number of DALYs or deaths that would need to be averted in order for the EDS to be considered cost-effective. Results The total costs of the EDS per district per year ranged between US$ 14,439 and 15,512. Salaries were identified as major cost-drivers, although their relative contribution to overall costs varied by country. Costs of relaying surveillance data between facilities and district offices (typically by hand) were also substantial. Data from Uganda indicated that 4% or more of overall costs could potentially be saved by switching to data transfer via mobile phones. Based on commonly used thresholds, 96 DALYs in Uganda and 103 DALYs in Kenya would need to be averted annually in each district for the EDS to be considered cost-effective. Conclusion Results from this analysis suggest that EDS are likely to be cost-effective. Further studies that include the costs and effects of the health systems' reaction prompted by EDS will need to be undertaken in order to obtain comprehensive cost-effectiveness estimates. PMID:19149878
Costs of early detection systems for epidemic malaria in highland areas of Kenya and Uganda.
Mueller, Dirk H; Abeku, Tarekegn A; Okia, Michael; Rapuoda, Beth; Cox, Jonathan
2009-01-16
Malaria epidemics cause substantial morbidity and mortality in highland areas of Africa. The costs of detecting and controlling these epidemics have not been explored adequately in the past. This study presents the costs of establishing and running an early detection system (EDS) for epidemic malaria in four districts in the highlands of Kenya and Uganda. An economic costing was carried out from the health service provider's perspective in both countries. Staff time for data entry and processing, as well as supervising and coordinating EDS activities at district and national levels was recorded and associated opportunity costs estimated. A threshold analysis was carried out to determine the number of DALYs or deaths that would need to be averted in order for the EDS to be considered cost-effective. The total costs of the EDS per district per year ranged between US$ 14,439 and 15,512. Salaries were identified as major cost-drivers, although their relative contribution to overall costs varied by country. Costs of relaying surveillance data between facilities and district offices (typically by hand) were also substantial. Data from Uganda indicated that 4% or more of overall costs could potentially be saved by switching to data transfer via mobile phones. Based on commonly used thresholds, 96 DALYs in Uganda and 103 DALYs in Kenya would need to be averted annually in each district for the EDS to be considered cost-effective. Results from this analysis suggest that EDS are likely to be cost-effective. Further studies that include the costs and effects of the health systems' reaction prompted by EDS will need to be undertaken in order to obtain comprehensive cost-effectiveness estimates.
Saadatmand, Sepideh; Tilanus-Linthorst, Madeleine M A; Rutgers, Emiel J T; Hoogerbrugge, Nicoline; Oosterwijk, Jan C; Tollenaar, Rob A E M; Hooning, Maartje; Loo, Claudette E; Obdeijn, Inge-Marie; Heijnsdijk, Eveline A M; de Koning, Harry J
2013-09-04
To reduce mortality, women with a family history of breast cancer are often screened with mammography before age 50 years. Additional magnetic resonance imaging (MRI) improves sensitivity and is cost-effective for BRCA1/2 mutation carriers. However, for women with a family history without a proven mutation, cost-effectiveness is unclear. We evaluated data of the largest prospective MRI screening study (MRISC). Between 1999 and 2007, 1597 women (8370 woman-years at risk) aged 25 to 70 years with an estimated cumulative lifetime risk of 15% to 50% for breast cancer were screened with clinical breast examination every 6 months and with annual mammography and MRI. We calculated the cost per detected and treated breast cancer. After incorporating MRISC data into a microsimulation screening analysis model (MISCAN), different schemes were evaluated, and cost per life-year gained (LYG) was estimated in comparison with the Dutch nationwide breast cancer screening program (biennial mammography from age 50 to 75 years). All statistical tests were two-sided. Forty-seven breast cancers (9 ductal carcinoma in situ) were detected. Screening with additional MRI costs $123 672 (€93 639) per detected breast cancer. In increasing age-cohorts, costs per detected and treated breast cancer decreased, but, unexpectedly, the percentage of MRI-only detected cancers increased. Screening under the MRISC-scheme from age 35 to 50 years was estimated to reduce breast cancer mortality by 25% at $134 932 (€102 164) per LYG (3.5% discounting) compared with 17% mortality reduction at $54 665 (€41 390) per LYG with mammography only. Screening with MRI may improve survival for women with familial risk for breast cancer but is expensive, especially in the youngest age categories.
Wziątek-Nowak, Weronika; Gierczyński, Jakub; Dąbrowiecki, Piotr; Gałązka-Sobotka, Małgorzata; Fal, Andrzej M; Gryglewicz, Jerzy; Badyda, Artur J
2016-01-01
Chronic obstructive pulmonary disease (COPD) is currently the third most common cause of death worldwide and the total number of people affected reaches over 200 million. It is estimated that approximately 50 % of persons having COPD are not aware of it. In the EU, it is estimated that the total annual costs of COPD exceed €140 billion, and the expected increase in the number of cases and deaths due to COPD would further enhance economic and social costs of the disease. In this article we present the results of cost analysis of health care benefits associated with the treatment of COPD and with the disease-related incapacity for work. The analysis is based on the data of the National Health Fund and the Social Insurance Institutions, public payers of health benefits in Poland. The annual 2012 expenditures incurred for COPD treatment was €40 million, and the benefits associated with incapacity for work reached more than €55 million. The extent of these expenditures indicates that it is necessary to optimize the functioning system, including the allocation of resources for prevention, social awareness, and detection of COPD at early stages when treatment costs are relatively low.
A low-cost video-oculography system for vestibular function testing.
Jihwan Park; Youngsun Kong; Yunyoung Nam
2017-07-01
In order to remain in focus during head movements, vestibular-ocular reflex causes eyes to move in the opposite direction to head movement. Disorders of vestibular system decrease vision, causing abnormal nystagmus and dizziness. To diagnose abnormal nystagmus, various studies have been reported including the use of rotating chair tests and videonystagmography. However, these tests are unsuitable for home use due to their high costs. Thus, a low-cost video-oculography system is necessary to obtain clinical features at home. In this paper, we present a low-cost video-oculography system using an infrared camera and Raspberry Pi board for tracking the pupils and evaluating a vestibular system. Horizontal eye movement is derived from video data obtained from an infrared camera and infrared light-emitting diodes, and the velocity of head rotation is obtained from a gyroscope sensor. Each pupil was extracted using a morphology operation and a contour detection method. Rotatory chair tests were conducted with our developed device. To evaluate our system, gain, asymmetry, and phase were measured and compared with System 2000. The average IQR errors of gain, phase and asymmetry were 0.81, 2.74 and 17.35, respectively. We showed that our system is able to measure clinical features.
Development of novel wireless sensor for food quality detection
NASA Astrophysics Data System (ADS)
Son Nguyen, Dat; Ngan Le, Nguyen; Phat Lam, Tan; Fribourg-Blanc, Eric; Chien Dang, Mau; Tedjini, Smail
2015-12-01
In this paper we present a wireless sensor for the monitoring of food quality. We integrate sensing capability into ultrahigh frequency (UHF) radio-frequency identification (RFID) tags through the relationship between the physical read-range and permittivity of the object we label with the RFID tags. Using the known variations of food permittivity as a function of time, we can detect the contamination time at which a food product becomes unacceptable for consumption based on the measurement of read-range with the as-designed sensing tags. This low-cost UHF RFID passive sensor was designed and experimentally tested on beef, pork, and cheese with the same storage conditions as in supermarkets. The agreement between the experimental and simulation results show the potential of this technique for practical application in food-quality tracking.
Soft nanoimprint lithography on SiO2 sol-gel to elaborate sensitive substrates for SERS detection
NASA Astrophysics Data System (ADS)
Hamouda, Frédéric; Bryche, Jean-François; Aassime, Abdelhanin; Maillart, Emmanuel; Gâté, Valentin; Zanettini, Silvia; Ruscica, Jérémy; Turover, Daniel; Bartenlian, Bernard
2017-12-01
This paper presents a new alternative fabrication of biochemical sensor based on surface enhanced Raman scattering (SERS) by soft nanoimprint lithography (S-NIL) on SiO2 sol-gel. Stabilization of the sol-gel film is obtained by annealing which simplifies the manufacturing of these biosensors and is compatible with mass production at low cost. This detector relies on a specific pattern of gold nanodisks on a thin gold film to obtain a better sensitivity of molecules' detection. Characterizations of SERS devices were performed on a confocal Raman microspectrophotometer after a chemical functionalization. We report a lateral collapse effect on poly(diméthylsiloxane) (PDMS) stamp for specific nanostructure dimensions. This unintentional effect is used to evaluate S-NIL resolution in SiO2 sol-gel.
Geng, Xuhui; Shi, Meng; Ning, Haijing; Feng, Chunbo; Guan, Yafeng
2018-05-15
A compact and low-cost laser induced fluorescence (LIF) detector based on confocal structure for capillary flow systems was developed and applied for analysis of Her2 protein on single Hela cells. A low-power and low-cost 450 nm laser diode (LD) instead of a high quality laser was used as excitation light source. A compact optical design together with shortened optical path length improved the optical efficiency and detection sensitivity. A superior silicon based photodetector assembly was used for fluorescence detection instead of a photomultiplier (PMT). The limit of detection (LOD) for fluorescein sodium was 3 × 10 -12 M or 165 fluorescein molecules in detection volume measured on a homemade capillary electroosmotic driven (EOD)-LIF system, which was similar to commercial LIFs. Compared to commercial LIFs, the whole volume of our LIF was reduced to 1/2-1/3, and the cost was less than 1/3 of them. Copyright © 2018 Elsevier B.V. All rights reserved.
Detection of fungal hyphae using smartphone and pocket magnifier: going cellular.
Agarwal, Tushar; Bandivadekar, Pooja; Satpathy, Gita; Sharma, Namrata; Titiyal, Jeewan S
2015-03-01
The aim of this study was to detect fungal hyphae in a corneal scraping sample using a cost-effective assembly of smartphone and pocket magnifier. In this case report, a tissue sample was obtained by conventional corneal scraping from a clinically suspicious case of mycotic keratitis. The smear was stained with Gram stain, and a 10% potassium hydroxide mount was prepared. It was imaged using a smartphone coupled with a compact pocket magnifier and integrated light-emitting diode assembly at point-of-care. Photographs of multiple sections of slides were viewed using smartphone screen and pinch-to-zoom function. The same slides were subsequently screened under a light microscope by an experienced microbiologist. The scraping from the ulcer was also inoculated on blood agar and Sabouraud dextrose agar. Smartphone-based digital imaging revealed the presence of gram-positive organism with hyphae. Examination under a light microscope also yielded similar findings. Fusarium was cultured from the corneal scraping, confirming the diagnosis of mycotic keratitis. The patient responded to topical 5% natamycin therapy, with resolution of the ulcer after 4 weeks. Smartphones can be successfully used as novel point-of-care, cost-effective, reliable microscopic screening tools.
Veerasamy, Anitha; Madane, Srinivasa Rao; Sivakumar, K; Sivaraman, Audithan
2016-01-01
Growing attractiveness of Mobile Ad Hoc Networks (MANETs), its features, and usage has led to the launching of threats and attacks to bring negative consequences in the society. The typical features of MANETs, especially with dynamic topology and open wireless medium, may leave MANETs vulnerable. Trust management using uncertain reasoning scheme has previously attempted to solve this problem. However, it produces additional overhead while securing the network. Hence, a Location and Trust-based secure communication scheme (L&TS) is proposed to overcome this limitation. Since the design securing requires more than two data algorithms, the cost of the system goes up. Another mechanism proposed in this paper, Angle and Context Free Grammar (ACFG) based precarious node elimination and secure communication in MANETs, intends to secure data transmission and detect precarious nodes in a MANET at a comparatively lower cost. The Elliptic Curve function is used to isolate a malicious node, thereby incorporating secure data transfer. Simulation results show that the dynamic estimation of the metrics improves throughput by 26% in L&TS when compared to the TMUR. ACFG achieves 33% and 51% throughput increase when compared to L&TS and TMUR mechanisms, respectively.
Investigating the Impact of a Solar Eclipse on Atmospheric Radiation
NASA Astrophysics Data System (ADS)
Fender, Josh; Morse, Justin; Ringler, John; Galovich, Cynthia; Kuehn, Charles A.; Semak, Matthew
2018-06-01
We present a project that measured atmospheric muon flux as a function of altitude during a total solar eclipse. An auxiliary goal was to design and build a cost-effective muon detection device that is simple enough for those with minimal training to build. The detector is part of a self-contained autonomous payload that is carried to altitude aboard a weather balloon. The detection system consists of three Geiger counters connected to a coincidence circuit. This system, along with internal and external temperature sensors and an altimeter, are controlled by an onboard Arduino Mega microcontroller. An internal frame was constructed to house and protect the payload components using modular 3D-printed parts. The payload was launched during the 2017 solar eclipse from Guernsey, Wyoming, along the path of totality. Initial data analysis indicates that line-of-sight blockage of the sun due to a total eclipse produces a negligible difference in muon flux when compared to the results of previous daytime flights. The successful performance of the payload, its low overall cost, and its ease of use suggest that this project would be well-suited for individuals or groups such as high school or undergraduate science students to reproduce and enhance.
Ozaki, Christiane Y; Silveira, Caio R F; Andrade, Fernanda B; Nepomuceno, Roberto; Silva, Anderson; Munhoz, Danielle D; Yamamoto, Bruno B; Luz, Daniela; Abreu, Patrícia A E; Horton, Denise S P Q; Elias, Waldir P; Ramos, Oscar H P; Piazza, Roxane M F
2015-01-01
Diarrhea is a prevalent pathological condition frequently associated to the colonization of the small intestine by enterotoxigenic Escherichia coli (ETEC) strains, known to be endemic in developing countries. These strains can produce two enterotoxins associated with the manifestation of clinical symptoms that can be used to detect these pathogens. Although several detection tests have been developed, minimally equipped laboratories are still in need of simple and cost-effective methods. With the aim to contribute to the development of such diagnostic approaches, we describe here two mouse hybridoma-derived single chain fragment variable (scFv) that were produced in E. coli against enterotoxins of ETEC strains. Recombinant scFv were developed against ETEC heat-labile toxin (LT) and heat-stable toxin (ST), from previously isolated hybridoma clones. This work reports their design, construction, molecular and functional characterization against LT and ST toxins. Both antibody fragments were able to recognize the cell-interacting toxins by immunofluorescence, the purified toxins by ELISA and also LT-, ST- and LT/ST-producing ETEC strains. The developed recombinant scFvs against LT and ST constitute promising starting point for simple and cost-effective ETEC diagnosis.
Ahirwar, Rajesh; Nahar, Pradip
2016-01-01
The increasing demand for easily available and low-cost diagnostics has fuelled the development of aptasensors as platforms for rapid, sensitive, and point-of-care testing of target analytes. Recently, gold nanoparticle (AuNP)-based aptasensors have attracted wide recognition owing to their color transition properties which allow real-time rapid sensing of targets. In this study, we utilized the color transition property of aptamer-functionalized AuNPs to detect and quantify estrogen receptor alpha (ERα), a key biomarker protein in breast cancer. We found that the coating of AuNPs with unmodified ERα-RNA aptamer (GGGGUCAAGGUGACCCC) makes them resistant to salt-induced aggregation. However, addition of ERα to the aptamer-protected AuNPs results in their spontaneous aggregation as evident from a color transition from wine red to deep blue. On the basis of this, we developed an ERα aptasensor, with limits of detection and quantification of 0.64 and 2.16 ng/mL, respectively; the aptasensor can efficiently detect and quantify ERα in a working range of 10 ng/mL-5μg/mL protein. Validation of the aptasensor on cellular extracts of ERα-positive MCF-7 and ERα-deficient MDA-MB-231 breast cancer cells showed a target-selective response in ERα-positive samples but not in cellular extracts of ERα-deficient breast cancer cells. Further, the small size and simple fabrication chemistry of aptamers provide an additional benefit to make the ERα aptasensor a potentially useful and cost-effective tool in point-of-care analyses of ERα.
NASA Astrophysics Data System (ADS)
Martinenghi, E.; Di Sieno, L.; Contini, D.; Sanzaro, M.; Pifferi, A.; Dalla Mora, A.
2016-07-01
We present the design and preliminary characterization of the first detection module based on Silicon Photomultiplier (SiPM) tailored for single-photon timing applications. The aim of this work is to demonstrate, thanks to the design of a suitable module, the possibility to easily exploit SiPM in many applications as an interesting detector featuring large active area, similarly to photomultipliers tubes, but keeping the advantages of solid state detectors (high quantum efficiency, low cost, compactness, robustness, low bias voltage, and insensitiveness to magnetic field). The module integrates a cooled SiPM with a total photosensitive area of 1 mm2 together with the suitable avalanche signal read-out circuit, the signal conditioning, the biasing electronics, and a Peltier cooler driver for thermal stabilization. It is able to extract the single-photon timing information with resolution better than 100 ps full-width at half maximum. We verified the effective stabilization in response to external thermal perturbations, thus proving the complete insensitivity of the module to environment temperature variations, which represents a fundamental parameter to profitably use the instrument for real-field applications. We also characterized the single-photon timing resolution, the background noise due to both primary dark count generation and afterpulsing, the single-photon detection efficiency, and the instrument response function shape. The proposed module can become a reliable and cost-effective building block for time-correlated single-photon counting instruments in applications requiring high collection capability of isotropic light and detection efficiency (e.g., fluorescence decay measurements or time-domain diffuse optics systems).
Endo, Tatsuro; Kajita, Hiroshi; Kawaguchi, Yukio; Kosaka, Terumasa; Himi, Toshiyuki
2016-06-01
The development of high-sensitive, and cost-effective novel biosensors have been strongly desired for future medical diagnostics. To develop novel biosensor, the authors focused on the specific optical characteristics of photonic crystal. In this study, a label-free optical biosensor, polymer-based two-dimensional photonic crystal (2D-PhC) film fabricated using nanoimprint lithography (NIL), was developed for detection of C-reactive protein (CRP) in human serum. The nano-hole array constructed NIL-based 2D-PhC (hole diameter: 230 nm, distance: 230, depth: 200 nm) was fabricated on a cyclo-olefin polymer (COP) film (100 µm) using thermal NIL and required surface modifications to reduce nonspecific adsorption of target proteins. Antigen-antibody reactions on the NIL-based 2D-PhC caused changes to the surrounding refractive index, which was monitored as reflection spectrum changes in the visible region. By using surface modified 2D-PhC, the calculated detection limit for CRP was 12.24 pg/mL at an extremely short reaction time (5 min) without the need for additional labeling procedures and secondary antibody. Furthermore, using the dual-functional random copolymer, CRP could be detected in a pooled blood serum diluted 100× with dramatic reduction of nonspecific adsorption. From these results, the NIL-based 2D-PhC film has great potential for development of an on-site, high-sensitivity, cost-effective, label-free biosensor for medical diagnostics applications. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
18 CFR 301.7 - Average System Cost methodology functionalization.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 18 Conservation of Power and Water Resources 1 2014-04-01 2014-04-01 false Average System Cost methodology functionalization. 301.7 Section 301.7 Conservation of Power and Water Resources FEDERAL ENERGY... ACT § 301.7 Average System Cost methodology functionalization. (a) Functionalization of each Account...
18 CFR 301.7 - Average System Cost methodology functionalization.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 18 Conservation of Power and Water Resources 1 2012-04-01 2012-04-01 false Average System Cost methodology functionalization. 301.7 Section 301.7 Conservation of Power and Water Resources FEDERAL ENERGY... ACT § 301.7 Average System Cost methodology functionalization. (a) Functionalization of each Account...
18 CFR 301.7 - Average System Cost methodology functionalization.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 18 Conservation of Power and Water Resources 1 2013-04-01 2013-04-01 false Average System Cost methodology functionalization. 301.7 Section 301.7 Conservation of Power and Water Resources FEDERAL ENERGY... ACT § 301.7 Average System Cost methodology functionalization. (a) Functionalization of each Account...
18 CFR 301.7 - Average System Cost methodology functionalization.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 18 Conservation of Power and Water Resources 1 2011-04-01 2011-04-01 false Average System Cost methodology functionalization. 301.7 Section 301.7 Conservation of Power and Water Resources FEDERAL ENERGY... ACT § 301.7 Average System Cost methodology functionalization. (a) Functionalization of each Account...
König, H H; Barry, J C; Leidl, R; Zrenner, E
2000-04-01
Orthoptic screening in the kindergarten is one option to improve early detection of amblyopia in children aged 3 years. The purpose of this study was to analyse the cost-effectiveness of such a screening programme in Germany. Based on data from the literature and own experience gained from orthoptic screening in kindergarten a decision-analytic model was developed. According to the model, all children in kindergarten, aged 3 years, who had not been treated for amblyopia before, were subjected to an orthoptic examination. Non-cooperative children were reexamined in kindergarten after one year. Children with positive test results were examined by an ophthalmologist for diagnosis. Effects were measured by the number of newly diagnosed cases of amblyopia, non-obvious strabismus and amblyogenic refractive errors. Direct costs were estimated from a third-party payer perspective. The influence of uncertain model parameters was tested by sensitivity analysis. In the base analysis the cost per orthoptic screening test was DM 15.39. Examination by an ophthalmologist cost DM 71.20. The total cost of the screening programme in all German kindergartens was DM 6.1 million. With a 1.5% age-specific prevalence of undiagnosed cases, a sensitivity of 95% and a specificity of 98%, a total of 4,261 new cases would be detected. The cost-effectiveness ratio was DM 1,421 per case detected. Sensitivity analysis showed considerable influence of prevalence and specificity on the cost-effectiveness ratio. It was more cost-effective to re-screen non-cooperative children in kindergarten than to have them examined by an ophthalmologist straight-away. The decision-analytic model showed stable results which may serve as a basis for discussion on the implementation of orthoptic screening and for planning a field study.
Weetman, David; Mitchell, Sara N; Wilding, Craig S; Birks, Daniel P; Yawson, Alexander E; Essandoh, John; Mawejje, Henry D; Djogbenou, Luc S; Steen, Keith; Rippon, Emily J; Clarkson, Christopher S; Field, Stuart G; Rigden, Daniel J; Donnelly, Martin J
2015-06-01
Functionally constrained genes are ideal insecticide targets because disruption is often fatal, and resistance mutations are typically costly. Synaptic acetylcholinesterase (AChE) is an essential neurotransmission enzyme targeted by insecticides used increasingly in malaria control. In Anopheles and Culex mosquitoes, a glycine-serine substitution at codon 119 of the Ace-1 gene confers both resistance and fitness costs, especially for 119S/S homozygotes. G119S in Anopheles gambiae from Accra (Ghana) is strongly associated with resistance, and, despite expectations of cost, resistant 119S alleles are increasing significantly in frequency. Sequencing of Accra females detected only a single Ace-1 119S haplotype, whereas 119G diversity was high overall but very low at non-synonymous sites, evidence of strong purifying selection driven by functional constraint. Flanking microsatellites showed reduced diversity, elevated linkage disequilibrium and high differentiation of 119S, relative to 119G homozygotes across up to two megabases of the genome. Yet these signals of selection were inconsistent and sometimes weak tens of kilobases from Ace-1. This unexpected finding is attributable to apparently ubiquitous amplification of 119S alleles as part of a large copy number variant (CNV) far exceeding the size of the Ace-1 gene, whereas 119G alleles were unduplicated. Ace-1 CNV was detectable in archived samples collected when the 119S allele was rare in Ghana. Multicopy amplification of resistant alleles has not been observed previously and is likely to underpin the recent increase in 119S frequency. The large CNV compromised localization of the strong selective sweep around Ace-1, emphasizing the need to integrate CNV analysis into genome scans for selection. © 2015 The Authors. Molecular Ecology published by John Wiley & Sons Ltd.
Bergevin, Anna; Zick, Cathleen D; McVicar, Stephanie Browning; Park, Albert H
2015-12-01
In this study, we estimate an ex ante cost-benefit analysis of a Utah law directed at improving early cytomegalovirus (CMV) detection. We use a differential cost of treatment analysis for publicly insured CMV-infected infants detected by a statewide hearing-directed CMV screening program. Utah government administrative data and multi-hospital accounting data are used to estimate and compare costs and benefits for the Utah infant population. If antiviral treatment succeeds in mitigating hearing loss for one infant per year, the public savings will offset the public costs incurred by screening and treatment. If antiviral treatment is not successful, the program represents a net cost, but may still have non-monetary benefits such as accelerated achievement of diagnostic milestones. The CMV education and treatment program costs are modest and show potential for significant cost savings. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Gumà-Uriel, Laura; Peñarrubia-María, M Teresa; Cerdà-Lafont, Marta; Cunillera-Puertolas, Oriol; Almeda-Ortega, Jesús; Fernández-Vergel, Rita; García-Campayo, Javier; Luciano, Juan V
2016-06-01
Data is lacking on comorbid personality disorders (PD) and fibromyalgia syndrome (FMS) in terms of prevalence, and associated healthcare and societal costs. The main aim of this study was to assess the prevalence of PD in FMS patients and to analyse whether the presence of comorbid PD is related to worse functional impairment and greater healthcare (medical visits, drug consumption, and medical tests) and societal costs. A cross-sectional study was performed using the baseline data of 216 FMS patients participating in a randomized, controlled trial carried out in three primary health care centres situated in the region of Barcelona, Spain. Measurement instruments included the International Personality Disorder Examination - Screening Questionnaire (IPDE-SQ), the Fibromyalgia Impact Questionnaire (FIQ), the Client Service Receipt Inventory (CSRI), and a socio-demographic questionnaire. Most patients (65 %) had a potential PD according to the IPDE-SQ. The most prevalent PD were the avoidant (41.4 %), obsessive-compulsive (33.1 %), and borderline (27 %). We found statistically significant differences in functional impairment (FIQ scores) between FMS patients with potential PD vs non-PD (59.2 vs 51.1; p < 0.001). Multivariate regression analyses revealed that higher FIQ total scores and the presence of potential PD were related to more healthcare costs (primary and specialised care visits). As expected, PD are frequent comorbid conditions in patients with FMS. Our results suggest that the screening of comorbid PD in patients with FMS might be recommendable in order to detect potential frequent attenders to primary and specialised care.
MICRONERVA: A Novel Approach to Large Aperture Astronomical Spectroscopy
NASA Astrophysics Data System (ADS)
Hall, Ryan; Plavchan, Peter; Geneser, Claire; Giddens, Frank; Spangler, Sophia
2016-06-01
MICRONERVA (MICRO Novel Exoplanet Radial Velocity Array) is a project to measure precise spectroscopic radial velocities. The cost of telescopes are a strong function of diameter, and light gathering power as opposed to angular resolution is the fundamental driver for telescope design for many spectroscopic science applications. By sacrificing angular resolution, many multiple smaller fiber-fed telescopes can be combined to synthesize the light gathering power of a larger diameter telescope at a lower effective cost. For our MICRONERVA prototype, based upon the larger MINERVA project, we will attempt to demonstrate that an array of four 8-inch CPC Celestron telescopes can be automated with sufficient active guiding precision for robust nightly robotic operations. The light from each telescope is coupled into single mode fibers, which are conveniently matched to the point spread function of 8-inch telescopes, which can be diffraction limited at red wavelengths in typical seeing at good observing sites. Additionally, the output from an array of single mode fibers provides stable output illumination of a spectrograph, which is a critical requirement of future precise radial velocity instrumentation. All of the hardware from the system is automated using Python programs and ASCOM and MaxIm DL software drivers. We will present an overview of the current status of the project and plans for future work. The detection of exoplanets using the techniques of MICRONERVA could potentially enable cost reductions for many types of spectroscopic research.
Are Education Cost Functions Ready for Prime Time? An Examination of Their Validity and Reliability
ERIC Educational Resources Information Center
Duncombe, William; Yinger, John
2011-01-01
This article makes the case that cost functions are the best available methodology for ensuring consistency between a state's educational accountability system and its education finance system. Because they are based on historical data and well-known statistical methods, cost functions are a particularly flexible and low-cost way to forecast what…
Turner‐Stokes, L; Paul, S; Williams, H
2006-01-01
Objectives To examine functional outcomes from a rehabilitation programme and to compare two methods for evaluating cost efficiency of rehabilitation in patients with severe complex disability. Subjects and setting Two hundred and ninety seven consecutive admissions to a specialist inpatient rehabilitation unit following severe acquired brain injury. Methods Retrospective analysis of routinely collected data, including the Functional Independence Measure (FIM), Barthel Index, and Northwick Park Dependency Score and Care Needs Assessment (NPDS/NPCNA), which provides a generic estimation of dependency, care hours. and weekly cost of continuing care in the community. Patients were analysed in three groups according to dependency on admission: “low” (NPDS<10 (n = 83)); “medium” (NPDS10–24 (n = 112)); “high” (NPDS >24 (n = 102)). Results Mean length of stay (LOS) 112 (SD 66) days. All groups showed significant reduction in dependency between admission and discharge on all measures (paired t tests: p<0.001). Mean reduction in “weekly cost of care” was greatest in the high dependency group at £639 per week (95% CI 488 to 789)), as compared with the medium (£323/week (95% CI 217 to 428)), and low (£111/week (95% CI 42 to 179)) dependency groups. Despite their longer LOS, time taken to offset the initial cost of rehabilitation was only 16.3 months in the high dependency group, compared with 21.5 months (medium dependency) and 38.8 months (low dependency). FIM efficiency (FIM gain/LOS) appeared greatest in the medium dependency group (0.25), compared with the low (0.17) and high (0.16) dependency groups. Conclusions The NPDS/NPCNA detected changes in dependency potentially associated with substantial savings in the cost of ongoing care, especially in high dependency patients. Floor effects in responsiveness of the FIM may lead to underestimation of efficiency of rehabilitation in higher dependency patients. PMID:16614023
Costs and quality of life of patients with ankylosing spondylitis in Hong Kong.
Zhu, T Y; Tam, L-S; Lee, V W-Y; Hwang, W W; Li, T K; Lee, K K; Li, E K
2008-09-01
To assess the annual direct, indirect and total societal costs, quality of life (QoL) of AS in a Chinese population in Hong Kong and determine the cost determinants. A retrospective, non-randomized, cross-sectional study was performed in a cohort of 145 patients with AS in Hong Kong. Participants completed questionnaires on sociodemographics, work status and out-of-pocket expenses. Health resources consumption was recorded by chart review. Functional impairment and disease activity were measured using the Bath Ankylosing Spondylitis Functional Index (BASFI) and the Bath Ankylosing Spondylitis Disease Activity Index (BASDAI), respectively. Patients' QoL was assessed using the Short Form-36 (SF-36). The mean age of the patients was 40 yrs with mean disease duration of 10 yrs. The mean BASDAI score was 4.7 and BASFI score was 3.3. Annual total costs averaged USD 9120. Direct costs accounted for 38% of the total costs while indirect costs accounted for 62%. Costs of technical examinations represented the largest proportion of total cost. Patients with AS reported significantly impaired QoL. Functional impairment became the major cost driver of direct costs and total costs. There is a substantial societal cost related to the treatment of AS in Hong Kong. Functional impairment is the most important cost driver. Treatments that reduce functional impairment may be effective to decrease the costs of AS and improve the patient's QoL, and ease the pressure on the healthcare system.
Analysis of the temporal program of replication initiation in yeast chromosomes.
Friedman, K L; Raghuraman, M K; Fangman, W L; Brewer, B J
1995-01-01
The multiple origins of eukaryotic chromosomes vary in the time of their initiation during S phase. In the chromosomes of Saccharomyces cerevisiae the presence of a functional telomere causes nearby origins to delay initiation until the second half of S phase. The key feature of telomeres that causes the replication delay is the telomeric sequence (C(1-3)A/G(1-3)T) itself and not the proximity of the origin to a DNA end. A second group of late replicating origins has been found at an internal position on chromosome XIV. Four origins, spanning approximately 140 kb, initiate replication in the second half of S phase. At least two of these internal origins maintain their late replication time on circular plasmids. Each of these origins can be separated into two functional elements: those sequences that provide origin function and those that impose late activation. Because the assay for determining replication time is costly and laborious, it has not been possible to analyze in detail these 'late' elements. We report here the development of two new assays for determining replication time. The first exploits the expression of the Escherichia coli dam methylase in yeast and the characteristic period of hemimethylation that transiently follows the passage of a replication fork. The second uses quantitative hybridization to detect two-fold differences in the amount of specific restriction fragments as a function of progress through S phase. The novel aspect of this assay is the creation in vivo of a non-replicating DNA sequence by site-specific pop-out recombination. This non-replicating fragment acts as an internal control for copy number within and between samples. Both of these techniques are rapid and much less costly than the more conventional density transfer experiments that require CsCl gradients to detect replicated DNA. With these techniques it should be possible to identify the sequences responsible for late initiation, to search for other late replicating regions in the genome, and to begin to analyze the effect that altering the temporal program has on chromosome function.
Malik, Akhtar Hussain; Hussain, Sameer; Kalita, Anamika; Iyer, Parameswar Krishnan
2015-12-09
Spontaneously formed conjugated polymer nanoparticles (CPNs) or polymer dots displayed remarkable fluorescence response toward nitroexplosive-picric acid (PA) in multiple environments including 100% aqueous media, solid support using portable paper strips and vapor phase detection via two terminal device. This new cationic conjugated polyelectrolyte (CPE) poly(3,3'-((2-phenyl-9H-fluorene-9,9-diyl)bis(hexane-6,1-diyl))bis(1-methyl-1H-imidazol-3-ium)bromide) (PFMI) was synthesized by Suzuki coupling polymerization followed by post functionalization method without employing any hectic purification technique. Highest quenching constant value (K(sv)) of 1.12 × 10(8) M(-1) and a very low detection limit of 30.9 pM/7.07 ppt were obtained exclusively for PA in 100% aqueous environment which is rare and unique for any CPE/CPNs. Contact mode detection of PA was also performed using simple, cost-effective and portable fluorescent paper strips for achieving on-site detection. Furthermore, the two terminal sensor device fabricated with nanoparticles of PFMI (PFMI-NPs) provides an exceptional and unprecedented platform for the vapor mode detection of PA under ambient conditions. The mechanism for the ultrasensitivity of PFMI-NPs probe to detect PA is attributed to the "molecular-wire effect", electrostatic interaction, photoinduced electron transfer (PET), and possible resonance energy transfer (RET).
NASA Astrophysics Data System (ADS)
Mandache, C.; Khan, M.; Fahr, A.; Yanishevsky, M.
2011-03-01
Probability of detection (PoD) studies are broadly used to determine the reliability of specific nondestructive inspection procedures, as well as to provide data for damage tolerance life estimations and calculation of inspection intervals for critical components. They require inspections on a large set of samples, a fact that makes these statistical assessments time- and cost-consuming. Physics-based numerical simulations of nondestructive testing inspections could be used as a cost-effective alternative to empirical investigations. They realistically predict the inspection outputs as functions of the input characteristics related to the test piece, transducer and instrument settings, which are subsequently used to partially substitute and/or complement inspection data in PoD analysis. This work focuses on the numerical modelling aspects of eddy current testing for the bolt hole inspections of wing box structures typical of the Lockheed Martin C-130 Hercules and P-3 Orion aircraft, found in the air force inventory of many countries. Boundary element-based numerical modelling software was employed to predict the eddy current signal responses when varying inspection parameters related to probe characteristics, crack geometry and test piece properties. Two demonstrator exercises were used for eddy current signal prediction when lowering the driver probe frequency and changing the material's electrical conductivity, followed by subsequent discussions and examination of the implications on using simulated data in the PoD analysis. Despite some simplifying assumptions, the modelled eddy current signals were found to provide similar results to the actual inspections. It is concluded that physics-based numerical simulations have the potential to partially substitute or complement inspection data required for PoD studies, reducing the cost, time, effort and resources necessary for a full empirical PoD assessment.
Yamagishi, Kazumasa; Sato, Shinichi; Kitamura, Akihiko; Kiyama, Masahiko; Okada, Takeo; Tanigawa, Takeshi; Ohira, Tetsuya; Imano, Hironori; Kondo, Masahide; Okubo, Ichiro; Ishikawa, Yoshinori; Shimamoto, Takashi; Iso, Hiroyasu
2012-09-01
The nation-wide, community-based intensive hypertension detection and control program, as well as universal health insurance coverage, may well be contributing factors for helping Japan rank near the top among countries with the longest life expectancy. We sought to examine the cost-effectiveness of such a community-based intervention program, as no evidence has been available for this issue. The hypertension detection and control program was initiated in 1963 in full intervention and minimal intervention communities in Akita, Japan. We performed comparative cost-effectiveness and budget-impact analyses for the period 1964-1987 of the costs of public health services and treatment of patients with hypertension and stroke on the one hand, and incidence of stroke on the other in the full intervention and minimal intervention communities. The program provided in the full intervention community was found to be cost saving 13 years after the beginning of program in addition to the fact of effectiveness that; the prevalence and incidence of stroke were consistently lower in the full intervention community than in the minimal intervention community throughout the same period. The incremental cost was minus 28,358 yen per capita over 24 years. The community-based intensive hypertension detection and control program was found to be both effective and cost saving. The national government's policy to support this program may have contributed in part to the substantial decline in stroke incidence and mortality, which was largely responsible for the increase in Japanese life expectancy.
ERIC Educational Resources Information Center
Economou, A.; Papargyris, D.; Stratis, J.
2004-01-01
The development of an FI analyzer for chemiluminescence detection using a low-cost photoiodide is presented. The experiment clearly demonstrates in a single interdisciplinary project the way in which different aspects in chemical instrumentation fit together to produce a working analytical system.
49 CFR Appendix A to Part 1511 - Aviation Security Infrastructure Fee
Code of Federal Regulations, 2011 CFR
2011-10-01
... final acceptance testing. This includes such equipment as Metal Detection Devices, Hand Wands, X-ray... such equipment as Metal Detection Devices, Hand Wands, X-ray screening machines, Explosives Trace... as test objects and X-ray radiation surveys, electricity costs and maintenance contract costs...
Optimizing bulk milk dioxin monitoring based on costs and effectiveness.
Lascano-Alcoser, V H; Velthuis, A G J; van der Fels-Klerx, H J; Hoogenboom, L A P; Oude Lansink, A G J M
2013-07-01
Dioxins are environmental pollutants, potentially present in milk products, which have negative consequences for human health and for the firms and farms involved in the dairy chain. Dioxin monitoring in feed and food has been implemented to detect their presence and estimate their levels in food chains. However, the costs and effectiveness of such programs have not been evaluated. In this study, the costs and effectiveness of bulk milk dioxin monitoring in milk trucks were estimated to optimize the sampling and pooling monitoring strategies aimed at detecting at least 1 contaminated dairy farm out of 20,000 at a target dioxin concentration level. Incidents of different proportions, in terms of the number of contaminated farms, and concentrations were simulated. A combined testing strategy, consisting of screening and confirmatory methods, was assumed as well as testing of pooled samples. Two optimization models were built using linear programming. The first model aimed to minimize monitoring costs subject to a minimum required effectiveness of finding an incident, whereas the second model aimed to maximize the effectiveness for a given monitoring budget. Our results show that a high level of effectiveness is possible, but at high costs. Given specific assumptions, monitoring with 95% effectiveness to detect an incident of 1 contaminated farm at a dioxin concentration of 2 pg of toxic equivalents/g of fat [European Commission's (EC) action level] costs €2.6 million per month. At the same level of effectiveness, a 73% cost reduction is possible when aiming to detect an incident where 2 farms are contaminated at a dioxin concentration of 3 pg of toxic equivalents/g of fat (EC maximum level). With a fixed budget of €40,000 per month, the probability of detecting an incident with a single contaminated farm at a dioxin concentration equal to the EC action level is 4.4%. This probability almost doubled (8.0%) when aiming to detect the same incident but with a dioxin concentration equal to the EC maximum level. This study shows that the effectiveness of finding an incident depends not only on the ratio at which, for testing, collected truck samples are mixed into a pooled sample (aiming at detecting certain concentration), but also the number of collected truck samples. In conclusion, the optimal cost-effective monitoring depends on the number of contaminated farms and the concentration aimed at detection. The models and study results offer quantitative support to risk managers of food industries and food safety authorities. Copyright © 2013 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Gendreau, Audrey
Efficient self-organizing virtual clusterheads that supervise data collection based on their wireless connectivity, risk, and overhead costs, are an important element of Wireless Sensor Networks (WSNs). This function is especially critical during deployment when system resources are allocated to a subsequent application. In the presented research, a model used to deploy intrusion detection capability on a Local Area Network (LAN), in the literature, was extended to develop a role-based hierarchical agent deployment algorithm for a WSN. The resulting model took into consideration the monitoring capability, risk, deployment distribution cost, and monitoring cost associated with each node. Changing the original LAN methodology approach to model a cluster-based sensor network depended on the ability to duplicate a specific parameter that represented the monitoring capability. Furthermore, other parameters derived from a LAN can elevate costs and risk of deployment, as well as jeopardize the success of an application on a WSN. A key component of the approach presented in this research was to reduce the costs when established clusterheads in the network were found to be capable of hosting additional detection agents. In addition, another cost savings component of the study addressed the reduction of vulnerabilities associated with deployment of agents to high volume nodes. The effectiveness of the presented method was validated by comparing it against a type of a power-based scheme that used each node's remaining energy as the deployment value. While available energy is directly related to the model used in the presented method, the study deliberately sought out nodes that were identified with having superior monitoring capability, cost less to create and sustain, and are at low-risk of an attack. This work investigated improving the efficiency of an intrusion detection system (IDS) by using the proposed model to deploy monitoring agents after a temperature sensing application had established the network traffic flow to the sink. The same scenario was repeated using a power-based IDS to compare it against the proposed model. To identify a clusterhead's ability to host monitoring agents after the temperature sensing application terminated, the deployed IDS utilized the communication history and other network factors in order to rank the nodes. Similarly, using the node's communication history, the deployed power-based IDS ranked nodes based on their remaining power. For each individual scenario, and after the IDS application was deployed, the temperature sensing application was run for a second time. This time, to monitor the temperature sensing agents as the data flowed towards the sink, the network traffic was rerouted through the new intrusion detection clusterheads. Consequently, if the clusterheads were shared, the re-routing step was not preformed. Experimental results in this research demonstrated the effectiveness of applying a robust deployment metric to improve upon the energy efficiency of a deployed application in a multi-application WSN. It was found that in the scenarios with the intrusion detection application that utilized the proposed model resulted in more remaining energy than in the scenarios that implemented the power-based IDS. The algorithm especially had a positive impact on the small, dense, and more homogeneous networks. This finding was reinforced by the smaller percentage of new clusterheads that was selected. Essentially, the energy cost of the route to the sink was reduced because the network traffic was rerouted through fewer new clusterheads. Additionally, it was found that the intrusion detection topology that used the proposed approach formed smaller and more connected sets of clusterheads than the power-based IDS. As a consequence, this proposed approach essentially achieved the research objective for enhancing energy use in a multi-application WSN.
NASA Astrophysics Data System (ADS)
Ren, Yihui
As real-world complex networks are heterogeneous structures, not all their components such as nodes, edges and subgraphs carry the same role or importance in the functions performed by the networks: some elements are more critical than others. Understanding the roles of the components of a network is crucial for understanding the behavior of the network as a whole. One the most basic function of networks is transport; transport of vehicles/people, information, materials, forces, etc., and these quantities are transported along edges between source and destination nodes. For this reason, network path-based importance measures, also called centralities, play a crucial role in the understanding of the transport functions of the network and the network's structural and dynamical behavior in general. In this thesis we study the notion of betweenness centrality, which measures the fraction of lowest-cost (or shortest) paths running through a network component, in particular through a node or an edge. High betweenness centrality nodes/edges are those that will be frequently used by the entities transported through the network and thus they play a key role in the overall transport properties of the network. In the first part of the thesis we present a first-principles based method for traffic prediction using a cost-based generalization of the radiation model (emission/absorbtion model) for human mobility, coupled with a cost-minimizing algorithm for efficient distribution of the mobility fluxes through the network. Using US census and highway traffic data, we show that traffic can efficiently and accurately be computed from a range-limited, network betweenness type calculation. The model based on travel time costs captures the log-normal distribution of the traffic and attains a high Pearson correlation coefficient (0.75) when compared with real traffic. We then focus on studying the extent of changes in traffic flows in the wake of a localized damage or alteration to the network and we demonstrate that the changes can propagate globally, affecting traffic several hundreds of miles away. Because of its principled nature, this method can inform many applications related to human mobility driven flows in spatial networks, ranging from transportation, through urban planning to mitigation of the effects of catastrophic events. In the second part of the thesis we focus on network deconstruction and community detection problems, both intensely studied topics in network science, using a weighted betweenness centrality approach. We present an algorithm that solves both problems efficiently and accurately and demonstrate that on both benchmark networks and data networks.
Heimeshoff, Mareike; Schreyögg, Jonas; Kwietniewski, Lukas
2014-06-01
This is the first study to use stochastic frontier analysis to estimate both the technical and cost efficiency of physician practices. The analysis is based on panel data from 3,126 physician practices for the years 2006 through 2008. We specified the technical and cost frontiers as translog function, using the one-step approach of Battese and Coelli to detect factors that influence the efficiency of general practitioners and specialists. Variables that were not analyzed previously in this context (e.g., the degree of practice specialization) and a range of control variables such as a patients' case-mix were included in the estimation. Our results suggest that it is important to investigate both technical and cost efficiency, as results may depend on the type of efficiency analyzed. For example, the technical efficiency of group practices was significantly higher than that of solo practices, whereas the results for cost efficiency differed. This may be due to indivisibilities in expensive technical equipment, which can lead to different types of health care services being provided by different practice types (i.e., with group practices using more expensive inputs, leading to higher costs per case despite these practices being technically more efficient). Other practice characteristics such as participation in disease management programs show the same impact throughout both cost and technical efficiency: participation in disease management programs led to an increase in both, technical and cost efficiency, and may also have had positive effects on the quality of care. Future studies should take quality-related issues into account.
Nanoplatforms for Detection, Remediation and Protection Against Chem-Bio Warfare
NASA Astrophysics Data System (ADS)
Denkbaş, E. B.; Bayram, C.; Kavaz, D.; Çirak, T.; Demirbilek, M.
Chemical and biological substances have been used as warfare agents by terrorists by varying degree of sophistication. It is critical that these agents be detected in real-time with high level of sensitively, specificity, and accuracy. Many different types of techniques and systems have been developed to detect these agents. But there are some limitations in these conventional techniques and systems. Limitations include the collection, handling and sampling procedures, detection limits, sample transfer, expensive equipment, personnel training, and detection materials. Due to the unique properties such as quantum effect, very high surface/volume ratio, enhanced surface reactivity, conductivity, electrical and magnetic properties of the nanomaterials offer great opportunity to develop very fast, sensitive, accurate and cost effective detection techniques and systems to detect chemical and biological (chem.-bio) warfare agents. Furthermore, surface modification of the materials is very easy and effective way to get functional or smart surfaces to be used as nano-biosensor platform. In that respect many different types of nanomaterials have been developed and used for the detection, remediation and protection, such as gold and silver nanoparticles, quantum dots, Nano chips and arrays, fluorescent polymeric and magnetic nanoparticles, fiber optic and cantilever based nanobiosensors, nanofibrillar nanostructures etc. This study summarizes preparation and characterization of nanotechnology based approaches for the detection of and remediation and protection against chem.-bio warfare agents.
Burgos, J L; Kahn, J G; Strathdee, S A; Valencia-Mendoza, A; Bautista-Arredondo, S; Laniado-Laborin, R; Castañeda, R; Deiss, R; Garfein, R S
2009-08-01
To assess the cost-effectiveness of screening for latent tuberculosis infection (LTBI) using a commercially available detection test and treating individuals at high risk for human immunodeficiency virus (HIV) infection in a middle-income country. We developed a Markov model to evaluate the cost per LTBI case detected, TB case averted and quality-adjusted life year (QALY) gained for a cohort of 1000 individuals at high risk for HIV infection over 20 years. Baseline model inputs for LTBI prevalence were obtained from published literature and cross-sectional data from tuberculosis (TB) screening using QuantiFERON-TB Gold In-Tube (QFT-GIT) testing among sex workers and illicit drug users at high risk for HIV recruited through street outreach in Tijuana, Mexico. Costs are reported in 2007 US dollars. Future costs and QALYs were discounted at 3% per year. Sensitivity analyses were performed to evaluate model robustness. Over 20 years, we estimate the program would prevent 78 cases of active TB and 55 TB-related deaths. The incremental cost per case of LTBI detected was US$730, cost per active TB averted was US$529 and cost per QALY gained was US$108. In settings of endemic TB and escalating HIV incidence, targeting LTBI screening and treatment among high-risk groups may be highly cost-effective.
Burgos, J. L.; Kahn, J. G.; Strathdee, S. A.; Valencia-Mendoza, A.; Bautista-Arredondo, S.; Laniado-Laborin, R.; Castañeda, R.; Deiss, R.; Garfein, R. S.
2009-01-01
SUMMARY OBJECTIVE To assess the cost-effectiveness of screening for latent tuberculosis infection (LTBI) using a commercially available detection test and treating individuals at high risk for human immunodeficiency virus (HIV) infection in a middle-income country. DESIGN We developed a Markov model to evaluate the cost per LTBI case detected, TB case averted and quality-adjusted life year (QALY) gained for a cohort of 1000 individuals at high risk for HIV infection over 20 years. Baseline model inputs for LTBI prevalence were obtained from published literature and cross-sectional data from tuberculosis (TB) screening using QuantiFERON®-TB Gold In-Tube (QFT-GIT) testing among sex workers and illicit drug users at high risk for HIV recruited through street outreach in Tijuana, Mexico. Costs are reported in 2007 US dollars. Future costs and QALYs were discounted at 3% per year. Sensitivity analyses were performed to evaluate model robustness. RESULTS Over 20 years, we estimate the program would prevent 78 cases of active TB and 55 TB-related deaths. The incremental cost per case of LTBI detected was US$730, cost per active TB averted was US$529 and cost per QALY gained was US$108. CONCLUSIONS In settings of endemic TB and escalating HIV incidence, targeting LTBI screening and treatment among high-risk groups may be highly cost-effective. PMID:19723375
Azman, Andrew S; Golub, Jonathan E; Dowdy, David W
2014-10-30
Current approaches are unlikely to achieve the aggressive global tuberculosis (TB) control targets set for 2035 and beyond. Active case finding (ACF) may be an important tool for augmenting existing strategies, but the cost-effectiveness of ACF remains uncertain. Program evaluators can often measure the cost of ACF per TB case detected, but how this accessible measure translates into traditional metrics of cost-effectiveness, such as the cost per disability-adjusted life year (DALY), remains unclear. We constructed dynamic models of TB in India, China, and South Africa to explore the medium-term impact and cost-effectiveness of generic ACF activities, conceptualized separately as discrete (2-year) campaigns and as continuous activities integrated into ongoing TB control programs. Our primary outcome was the cost per DALY, measured in relationship to the cost per TB case actively detected and started on treatment. Discrete campaigns costing up to $1,200 (95% uncertainty range [UR] 850-2,043) per case actively detected and started on treatment in India, $3,800 (95% UR 2,706-6,392) in China, and $9,400 (95% UR 6,957-13,221) in South Africa were all highly cost-effective (cost per DALY averted less than per capita gross domestic product). Prolonged integration was even more effective and cost-effective. Short-term assessments of ACF dramatically underestimated potential longer term gains; for example, an assessment of an ACF program at 2 years might find a non-significant 11% reduction in prevalence, but a 10-year evaluation of that same intervention would show a 33% reduction. ACF can be a powerful and highly cost-effective tool in the fight against TB. Given that short-term assessments may dramatically underestimate medium-term effectiveness, current willingness to pay may be too low. ACF should receive strong consideration as a basic tool for TB control in most high-burden settings, even when it may cost over $1,000 to detect and initiate treatment for each extra case of active TB.
Microfluidic Biosensing Systems Using Magnetic Nanoparticles
Giouroudi, Ioanna; Keplinger, Franz
2013-01-01
In recent years, there has been rapidly growing interest in developing hand held, sensitive and cost-effective on-chip biosensing systems that directly translate the presence of certain bioanalytes (e.g., biomolecules, cells and viruses) into an electronic signal. The impressive and rapid progress in micro- and nanotechnology as well as in biotechnology enables the integration of a variety of analytical functions in a single chip. All necessary sample handling and analysis steps are then performed within the chip. Microfluidic systems for biomedical analysis usually consist of a set of units, which guarantees the manipulation, detection and recognition of bioanalytes in a reliable and flexible manner. Additionally, the use of magnetic fields for performing the aforementioned tasks has been steadily gaining interest. This is because magnetic fields can be well tuned and applied either externally or from a directly integrated solution in the biosensing system. In combination with these applied magnetic fields, magnetic nanoparticles are utilized. Some of the merits of magnetic nanoparticles are the possibility of manipulating them inside microfluidic channels by utilizing high gradient magnetic fields, their detection by integrated magnetic microsensors, and their flexibility due to functionalization by means of surface modification and specific binding. Their multi-functionality is what makes them ideal candidates as the active component in miniaturized on-chip biosensing systems. In this review, focus will be given to the type of biosening systems that use microfluidics in combination with magnetoresistive sensors and detect the presence of bioanalyte tagged with magnetic nanoparticles. PMID:24022689
NASA Astrophysics Data System (ADS)
Francioso, L.; De Pascali, C.; Pescini, E.; De Giorgi, M. G.; Siciliano, P.
2016-06-01
Preventing the flow separation could enhance the performance of propulsion systems and future civil aircraft. To this end, a fast detection of boundary layer separation is mandatory for a sustainable and successful application of active flow control devices, such as plasma actuators. The present work reports on the design, fabrication and functional tests of low-cost capacitive pressure sensors coupled with dielectric barrier discharge (DBD) plasma actuators to detect and then control flow separation. Finite element method (FEM) simulations were used to obtain information on the deflection and the stress distribution in different-shaped floating membranes. The sensor sensitivity as a function of the pressure load was also calculated by experimental tests. The results of the calibration of different capacitive pressure sensors are reported in this work, together with functional tests in a wind tunnel equipped with a curved wall plate on which a DBD plasma actuator was mounted to control the flow separation. The flow behavior was experimentally investigated by particle image velocimetry (PIV) measurements. Statistical and spectral analysis, applied to the output signals of the pressure sensor placed downstream of the profile leading edge, demonstrated that the sensor is able to discriminate different ionic wind velocity and turbulence conditions. The sensor sensitivity in the 0-100 Pa range was experimentally measured and it ranged between 0.0030 and 0.0046 pF Pa-1 for the best devices.
Ramon-Marquez, Teresa; Medina-Castillo, Antonio L; Fernandez-Gutierrez, Alberto; Fernandez-Sanchez, Jorge F
2016-05-15
In this paper, the combination of Solid Surface-Room Temperature Phosphorescence (SS-RTP) and nanotechnology has led to a new approach in the detection of biogenic amines in complex matrices. This novel approach allows, for the first time, the direct determination of the concentration of tryptamine in beers. The novelty of the proposed optical sensor resides in its simplicity, rapidity, absence of complex chromatographic separation, sample clean-up, preconcentration, and derivatization protocols. Therefore, this novel methodology simplifies and reduces considerably the time and cost of the analysis, resolving the two major problems of the determination of tryptamine in beer up to now: low sensitivity and matrix effects. The proposed sensor is based on a novel white, uncharged, and non-luminescent functional nonwoven nanofibre mat (Tiss®-Link) formed by hydrophilic nanofibres of 300 nm of diameter functionalized with a high concentration of active vinyl groups (330 µmol g(-1)). It is used to carry out a kinetically controlled covalent immobilisation of tryptamine via Michael type-reaction. The transduction of the sensor is phosphorescence; the covalently immobilized tryptamine is quantified by SS-RTP, obtaining a detection limit of 6 ng mL(-1) with short response times (15 min). The applicability of the sensor was demonstrated by analysing tryptamine in 10 different varieties of beers, obtaining recovery percentages close to 100%. Copyright © 2016 Elsevier B.V. All rights reserved.
MBE Growth of HgCdTe on Large-Area Si and CdZnTe Wafers for SWIR, MWIR and LWIR Detection
NASA Astrophysics Data System (ADS)
Reddy, M.; Peterson, J. M.; Lofgreen, D. D.; Franklin, J. A.; Vang, T.; Smith, E. P. G.; Wehner, J. G. A.; Kasai, I.; Bangs, J. W.; Johnson, S. M.
2008-09-01
Molecular beam epitaxy (MBE) growth of HgCdTe on large-size Si (211) and CdZnTe (211)B substrates is critical to meet the demands of extremely uniform and highly functional third-generation infrared (IR) focal-panel arrays (FPAs). We have described here the importance of wafer maps of HgCdTe thickness, composition, and the macrodefects across the wafer not only to qualify material properties against design specifications but also to diagnose and classify the MBE-growth-related issues on large-area wafers. The paper presents HgCdTe growth with exceptionally uniform composition and thickness and record low macrodefect density on large Si wafers up to 6-in in diameter for the detection of short-wave (SW), mid-wave (MW), and long-wave (LW) IR radiation. We have also proposed a cost-effective approach to use the growth of HgCdTe on low-cost Si substrates to isolate the growth- and substrate-related problems that one occasionally comes across with the CdZnTe substrates and tune the growth parameters such as growth rate, cutoff wavelength ( λ cutoff) and doping parameters before proceeding with the growth on costly large-area CdZnTe substrates. In this way, we demonstrated HgCdTe growth on large CdZnTe substrates of size 7 cm × 7 cm with excellent uniformity and low macrodefect density.
A cost effective real-time PCR for the detection of adenovirus from viral swabs
2013-01-01
Compared to traditional testing strategies, nucleic acid amplification tests such as real-time PCR offer many advantages for the detection of human adenoviruses. However, commercial assays are expensive and cost prohibitive for many clinical laboratories. To overcome fiscal challenges, a cost effective strategy was developed using a combination of homogenization and heat treatment with an “in-house” real-time PCR. In 196 swabs submitted for adenovirus detection, this crude extraction method showed performance characteristics equivalent to viral DNA obtained from a commercial nucleic acid extraction. In addition, the in-house real-time PCR outperformed traditional testing strategies using virus culture, with sensitivities of 100% and 69.2%, respectively. Overall, the combination of homogenization and heat treatment with a sensitive in-house real-time PCR provides accurate results at a cost comparable to viral culture. PMID:23758993
Bindoria, Suchitra V; Devkar, Ramesh; Gupta, Indrani; Ranebennur, Virupax; Saggurti, Niranjan; Ramesh, Sowmya; Deshmukh, Dilip; Gaikwad, Sanjeevsingh
2014-03-26
The objectives of this paper are: (1) to study the feasibility and relative benefits of integrating the prevention of parent-to-child transmission (PPTCT) component of the National AIDS Control Program with the maternal and child health component of the National Rural Health Mission (NRHM) by offering HIV screening at the primary healthcare level; and (2) to estimate the incremental cost-effectiveness ratio to understand whether the costs are commensurate with the benefits. The intervention included advocacy with political, administrative/health heads, and capacity building of health staff in Satara district, Maharashtra, India. The intervention also conducted biannual outreach activities at primary health centers (PHCs)/sub-centers (SCs); initiated facility-based integrated counseling and testing centers (FICTCs) at all round-the-clock PHCs; made the existing FICTCs functional and trained PHC nurses in HIV screening. All "functional" FICTCs were equipped to screen for HIV and trained staff provided counseling and conducted HIV testing as per the national protocol. Data were collected pre- and post- integration on the number of pregnant women screened for HIV, the number of functional FICTCs and intervention costs. Trend analyses on various outcome measures were conducted. Further, the incremental cost-effectiveness ratio per pregnant woman screened was calculated. An additional 27% of HIV-infected women were detected during the intervention period as the annual HIV screening increased from pre- to post-intervention (55% to 79%, p < 0.001) among antenatal care (ANC) attendees under the NRHM. A greater increase in HIV screening was observed in PHCs/SCs. The proportions of functional FICTCs increased from 47% to 97% (p < 0.001). Additionally, 93% of HIV-infected pregnant women were linked to anti-retroviral therapy centers; 92% of mother-baby pairs received Nevirapine; and 89% of exposed babies were enrolled for early infant diagnosis. The incremental cost-effectiveness ratio was estimated at INR 44 (less than 1 US$) per pregnant woman tested. Integrating HIV screening with the broader Rural Health Mission is a promising opportunity to scale up the PPTCT program. However, advocacy, sensitization, capacity building and the judicious utilization of available resources are key to widening the reach of the PPTCT program in India and elsewhere.
Miniaturization of the Clonogenic Assay Using Confluence Measurement
Mayr, Christian; Beyreis, Marlena; Dobias, Heidemarie; Gaisberger, Martin; Pichler, Martin; Ritter, Markus; Jakab, Martin; Neureiter, Daniel; Kiesslich, Tobias
2018-01-01
The clonogenic assay is a widely used method to study the ability of cells to ‘infinitely’ produce progeny and is, therefore, used as a tool in tumor biology to measure tumor-initiating capacity and stem cell status. However, the standard protocol of using 6-well plates has several disadvantages. By miniaturizing the assay to a 96-well microplate format, as well as by utilizing the confluence detection function of a multimode reader, we here describe a new and modified protocol that allows comprehensive experimental setups and a non-endpoint, label-free semi-automatic analysis. Comparison of bright field images with confluence images demonstrated robust and reproducible detection of clones by the confluence detection function. Moreover, time-resolved non-endpoint confluence measurement of the same well showed that semi-automatic analysis was suitable for determining the mean size and colony number. By treating cells with an inhibitor of clonogenic growth (PTC-209), we show that our modified protocol is suitable for comprehensive (broad concentration range, addition of technical replicates) concentration- and time-resolved analysis of the effect of substances or treatments on clonogenic growth. In summary, this protocol represents a time- and cost-effective alternative to the commonly used 6-well protocol (with endpoint staining) and also provides additional information about the kinetics of clonogenic growth. PMID:29510509
Zhou, Feng; Noor, M Omair; Krull, Ulrich J
2015-09-24
Bioassays based on cellulose paper substrates are gaining increasing popularity for the development of field portable and low-cost diagnostic applications. Herein, we report a paper-based nucleic acid hybridization assay using immobilized upconversion nanoparticles (UCNPs) as donors in luminescence resonance energy transfer (LRET). UCNPs with intense green emission served as donors with Cy3 dye as the acceptor. The avidin functionalized UCNPs were immobilized on cellulose paper and subsequently bioconjugated to biotinylated oligonucleotide probes. Introduction of unlabeled oligonucleotide targets resulted in a formation of probe-target duplexes. A subsequent hybridization of Cy3 labeled reporter with the remaining single stranded portion of target brought the Cy3 dye in close proximity to the UCNPs to trigger a LRET-sensitized emission from the acceptor dye. The hybridization assays provided a limit of detection (LOD) of 146.0 fmol and exhibited selectivity for one base pair mismatch discrimination. The assay was functional even in undiluted serum samples. This work embodies important progress in developing DNA hybridization assays on paper. Detection of unlabeled targets is achieved using UCNPs as LRET donors, with minimization of background signal from paper substrates owing to the implementation of low energy near-infrared (NIR) excitation.
Home health care cost-function analysis
Hay, Joel W.; Mandes, George
1984-01-01
An exploratory home health care (HHC) cost-function model is estimated using State rate-setting data for the 74 traditional (nonprofit) Connecticut agencies. The analysis demonstrates U-shaped average costs curves for agencies' provision of skilled nursing visits, with substantial diseconomies of scale in the observable range. It is determined from the estimated cost function that the sample representative agency is providing fewer visits than optimal, and its marginal cost is significantly below average cost. The finding that an agency's costs are predominantly related to output levels, with little systematic variation due to other agency or patient characteristics, suggests that the economic inefficiency in a cost-based HHC reimbursement policy may be substantial. PMID:10310596
Van De Gucht, Tim; Van Weyenberg, Stephanie; Van Nuffel, Annelies; Lauwers, Ludwig; Vangeyte, Jürgen; Saeys, Wouter
2017-10-08
Most automatic lameness detection system prototypes have not yet been commercialized, and are hence not yet adopted in practice. Therefore, the objective of this study was to simulate the effect of detection performance (percentage missed lame cows and percentage false alarms) and system cost on the potential market share of three automatic lameness detection systems relative to visual detection: a system attached to the cow, a walkover system, and a camera system. Simulations were done using a utility model derived from survey responses obtained from dairy farmers in Flanders, Belgium. Overall, systems attached to the cow had the largest market potential, but were still not competitive with visual detection. Increasing the detection performance or lowering the system cost led to higher market shares for automatic systems at the expense of visual detection. The willingness to pay for extra performance was €2.57 per % less missed lame cows, €1.65 per % less false alerts, and €12.7 for lame leg indication, respectively. The presented results could be exploited by system designers to determine the effect of adjustments to the technology on a system's potential adoption rate.
Cost, weight and lead time impacts of a Mercedes-Benz 'Sensormat' type occupant detection system
DOT National Transportation Integrated Search
1997-04-19
This summary report is based, in part, on the findings contained in Contract No. DTNH22-96-C-02063 entitled "Cost Analysis of the Mercedes-Benz Occupant Detection System for Air Bag Shut-Off" prepared by Ludtke and Associates of Washington, Michigan....
Cost analysis of the Mercedes-Benz occupant detection system for air bag shut-off
DOT National Transportation Integrated Search
1997-04-01
The objective of this project is to develop the variable manufacturing costs and lead time estimates of an "occupant detection system for air bag shut off". The Mercedes-Benz system was used as a base for developing this data. The system consists of ...
Javier, David J.; Castellanos-Gonzalez, Alejandro; Weigum, Shannon E.; White, A. Clinton; Richards-Kortum, Rebecca
2009-01-01
We report on a novel strategy for the detection of mRNA targets derived from Cryptosporidium parvum oocysts by the use of oligonucleotide-gold nanoparticles. Gold nanoparticles are functionalized with oligonucleotides which are complementary to unique sequences present on the heat shock protein 70 (HSP70) DNA/RNA target. The results indicate that the presence of HPS70 targets of increasing complexity causes the formation of oligonucleotide-gold nanoparticle networks which can be visually monitored via a simple colorimetric readout measured by a total internal reflection imaging setup. Furthermore, the induced expression of HSP70 mRNA in Cryptosporidium parvum oocysts via a simple heat shock process provides nonenzymatic amplification such that the HSP70 mRNA derived from as few as 5 × 103 purified C. parvum oocysts was successfully detected. Taken together, these results support the use of oligonucleotide-gold nanoparticles for the molecular diagnosis of cryptosporidiosis, offering new opportunities for the further development of point-of-care diagnostic assays with low-cost, robust reagents and simple colorimetric detection. PMID:19828740
The mid-IR silicon photonics sensor platform (Conference Presentation)
NASA Astrophysics Data System (ADS)
Kimerling, Lionel; Hu, Juejun; Agarwal, Anuradha M.
2017-02-01
Advances in integrated silicon photonics are enabling highly connected sensor networks that offer sensitivity, selectivity and pattern recognition. Cost, performance and the evolution path of the so-called `Internet of Things' will gate the proliferation of these networks. The wavelength spectral range of 3-8um, commonly known as the mid-IR, is critical to specificity for sensors that identify materials by detection of local vibrational modes, reflectivity and thermal emission. For ubiquitous sensing applications in this regime, the sensors must move from premium to commodity level manufacturing volumes and cost. Scaling performance/cost is critically dependent on establishing a minimum set of platform attributes for point, wearable, and physical sensing. Optical sensors are ideal for non-invasive applications. Optical sensor device physics involves evanescent or intra-cavity structures for applied to concentration, interrogation and photo-catalysis functions. The ultimate utility of a platform is dependent on sample delivery/presentation modalities; system reset, recalibration and maintenance capabilities; and sensitivity and selectivity performance. The attributes and performance of a unified Glass-on-Silicon platform has shown good prospects for heterogeneous integration on materials and devices using a low cost process flow. Integrated, single mode, silicon photonic platforms offer significant performance and cost advantages, but they require discovery and qualification of new materials and process integration schemes for the mid-IR. Waveguide integrated light sources based on rare earth dopants and Ge-pumped frequency combs have promise. Optical resonators and waveguide spirals can enhance sensitivity. PbTe materials are among the best choices for a standard, waveguide integrated photodetector. Chalcogenide glasses are capable of transmitting mid-IR signals with high transparency. Integrated sensor case studies of i) high sensitivity analyte detection in solution; ii) gas sensing in air and iii) on-chip spectrometry provide good insight into the tradeoffs being made en route to ubiquitous sensor deployment in an Internet of Things.
Valuation of opportunity costs by rats working for rewarding electrical brain stimulation.
Solomon, Rebecca Brana; Conover, Kent; Shizgal, Peter
2017-01-01
Pursuit of one goal typically precludes simultaneous pursuit of another. Thus, each exclusive activity entails an "opportunity cost:" the forgone benefits from the next-best activity eschewed. The present experiment estimates, in laboratory rats, the function that maps objective opportunity costs into subjective ones. In an operant chamber, rewarding electrical brain stimulation was delivered when the cumulative time a lever had been depressed reached a criterion duration. The value of the activities forgone during this duration is the opportunity cost of the electrical reward. We determined which of four functions best describes how objective opportunity costs, expressed as the required duration of lever depression, are translated into their subjective equivalents. The simplest account is the identity function, which equates subjective and objective opportunity costs. A variant of this function called the "sigmoidal-slope function," converges on the identity function at longer durations but deviates from it at shorter durations. The sigmoidal-slope function has the form of a hockey stick. The flat "blade" denotes a range over which opportunity costs are subjectively equivalent; these durations are too short to allow substitution of more beneficial activities. The blade extends into an upward-curving portion over which costs become discriminable and finally into the straight "handle," over which objective and subjective costs match. The two remaining functions are based on hyperbolic and exponential temporal discounting, respectively. The results are best described by the sigmoidal-slope function. That this is so suggests that different principles of intertemporal choice are involved in the evaluation of time spent working for a reward or waiting for its delivery. The subjective opportunity-cost function plays a key role in the evaluation and selection of goals. An accurate description of its form and parameters is essential to successful modeling and prediction of instrumental performance and reward-related decision making.
Co, Michael; Kwong, Ava
2017-04-01
Sentinel lymph node (SLN) biopsy is currently the gold standard of treatment in early breast cancers. Identification of SLNs by preoperative scintigraphy has been carried out to improve the detection of SLNs intraoperatively, but the evidence of its cost-effectiveness is lacking. Here, we analyze the cost-effectiveness of the utilization of scintigraphy in detection of SLNs. Clinical and operative details were retrieved from a prospectively maintained database. The resources and cost data from each patient who had undergone SLN biopsy with preoperative scintigraphy were retrieved. From January 2008 to December 2012, 400 patients underwent SLN biopsy for breast cancer. A total of 329 had preoperative SLN mapping with scintigraphy, Baseline patient demographic data for both arms were comparable. The relapse and recurrence rate of both arms were not statistically different. The detection rate of SLNs of both arms was the same (100%), and there were no grade 2 or above lymphedema in both groups of patients. However, the cost of each patient undergoing SLN mapping was USD $345.8. Preoperative SLN mapping does not improve the SLN detection rate. In addition, it does not affect the surgical outcomes in terms of complication, local relapse, and recurrence. The use of preoperative SLN mapping is no longer cost-effective. Copyright © 2016 Elsevier Inc. All rights reserved.
Estimating the cost of skin cancer detection by dermatology providers in a large health care system.
Matsumoto, Martha; Secrest, Aaron; Anderson, Alyce; Saul, Melissa I; Ho, Jonhan; Kirkwood, John M; Ferris, Laura K
2018-04-01
Data on the cost and efficiency of skin cancer detection through total body skin examination are scarce. To determine the number needed to screen (NNS) and biopsy (NNB) and cost per skin cancer diagnosed in a large dermatology practice in patients undergoing total body skin examination. This is a retrospective observational study. During 2011-2015, a total of 20,270 patients underwent 33,647 visits for total body skin examination; 9956 lesion biopsies were performed yielding 2763 skin cancers, including 155 melanomas. The NNS to detect 1 skin cancer was 12.2 (95% confidence interval [CI] 11.7-12.6) and 1 melanoma was 215 (95% CI 185-252). The NNB to detect 1 skin cancer was 3.0 (95% CI 2.9-3.1) and 1 melanoma was 27.8 (95% CI 23.3-33.3). In a multivariable model for NNS, age and personal history of melanoma were significant factors. Age switched from a protective factor to a risk factor at 51 years of age. The estimated cost per melanoma detected was $32,594 (95% CI $27,326-$37,475). Data are from a single health care system and based on physician coding. Melanoma detection through total body skin examination is most efficient in patients ≥50 years of age and those with a personal history of melanoma. Our findings will be helpful in modeling the cost effectiveness of melanoma screening by dermatologists. Copyright © 2017 American Academy of Dermatology, Inc. Published by Elsevier Inc. All rights reserved.
A heparin-functionalized carbon nanotube-based affinity biosensor for dengue virus.
Wasik, Daniel; Mulchandani, Ashok; Yates, Marylynn V
2017-05-15
Dengue virus is an arthropod-borne virus transmitted primarily by Aedes mosquitos and is major cause of disease in tropical and subtropical regions. Colloquially known as Dengue Fever, infection can cause hemorrhagic disorders and death in humans and non-human primates. We report a novel electronic biosensor based on a single-walled carbon nanotube network chemiresistive transducer that is functionalized with heparin for low-cost, label-free, ultra-sensitive, and rapid detection of whole dengue virus (DENV). Heparin, an analog of the heparan sulfate proteoglycans that are receptors for dengue virus during infection of Vero cells and hepatocytes, was used for the first time in a biosensor as a biorecognition element instead of traditional antibody. Detection of DENV in viral culture supernatant has similar sensitivity as the corresponding viral titer in phosphate buffer despite the presence of growth media and Vero cell lysate. The biosensor demonstrated sensitivity within the clinically relevant range for humans and infected Aedes aegypti. It has potential application in clinical diagnosis and can improve point-of-care diagnostics of dengue infection. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Raqeema, S.; Hashim, U.; Azizah, N.; Nadzirah, Sh.; Arshad, M. K. Md; Ruslinda, A. R.; Gopinath, Subash C. B.
2017-03-01
HPV that also called Human Papillomaviruses is the major cause of the cervical cancer. HPV 16 and HPV 18 are the two types of HPV are the most HPV-associated cancers and responsible as a high-risk HPV. Cervical cancer taken about 70 percent of all cases due HPV infections. Cervical malignancy for the most part development on a lady's cervix and its was developed slowly as cancer disease. TiO2 particles give better performance and low cost of the biosensor. The used of 3-aminopropyl triethoxysilane (APTES) will be more efficient for DNA nanochip. APTES used as absorption reaction to immobilize organic biomolecules on the inorganic surface. Besides, APTES give better functionalization of the adsorption mechanism on IDE. The surface functionalized for immobilizing the DNA, which is the combination of the DNA probe and the HPV target produce high sensitivity andfast detection of the IDE. The Current-Voltage (IV) characteristic proved the sensitivity of the DNA nanochip increase as the concentration varied from 0% concentration to 24% of APTES concentration.
Current trends in nanobiosensor technology
Wu, Diana; Langer, Robert S
2014-01-01
The development of tools and processes used to fabricate, measure, and image nanoscale objects has lead to a wide range of work devoted to producing sensors that interact with extremely small numbers (or an extremely small concentration) of analyte molecules. These advances are particularly exciting in the context of biosensing, where the demands for low concentration detection and high specificity are great. Nanoscale biosensors, or nanobiosensors, provide researchers with an unprecedented level of sensitivity, often to the single molecule level. The use of biomolecule-functionalized surfaces can dramatically boost the specificity of the detection system, but can also yield reproducibility problems and increased complexity. Several nanobiosensor architectures based on mechanical devices, optical resonators, functionalized nanoparticles, nanowires, nanotubes, and nanofibers have been demonstrated in the lab. As nanobiosensor technology becomes more refined and reliable, it is likely it will eventually make its way from the lab to the clinic, where future lab-on-a-chip devices incorporating an array of nanobiosensors could be used for rapid screening of a wide variety of analytes at low cost using small samples of patient material. PMID:21391305
A review of damage detection methods for wind turbine blades
NASA Astrophysics Data System (ADS)
Li, Dongsheng; Ho, Siu-Chun M.; Song, Gangbing; Ren, Liang; Li, Hongnan
2015-03-01
Wind energy is one of the most important renewable energy sources and many countries are predicted to increase wind energy portion of their whole national energy supply to about twenty percent in the next decade. One potential obstacle in the use of wind turbines to harvest wind energy is the maintenance of the wind turbine blades. The blades are a crucial and costly part of a wind turbine and over their service life can suffer from factors such as material degradation and fatigue, which can limit their effectiveness and safety. Thus, the ability to detect damage in wind turbine blades is of great significance for planning maintenance and continued operation of the wind turbine. This paper presents a review of recent research and development in the field of damage detection for wind turbine blades. Specifically, this paper reviews frequently employed sensors including fiber optic and piezoelectric sensors, and four promising damage detection methods, namely, transmittance function, wave propagation, impedance and vibration based methods. As a note towards the future development trend for wind turbine sensing systems, the necessity for wireless sensing and energy harvesting is briefly presented. Finally, existing problems and promising research efforts for online damage detection of turbine blades are discussed.
Detecting insect pollinator declines on regional and global scales
Lubuhn, Gretchen; Droege, Sam; Connor, Edward F.; Gemmill-Herren, Barbara; Potts, Simon G.; Minckley, Robert L.; Griswold, Terry; Jean, Robert; Kula, Emanuel; Roubik, David W.; Cane, Jim; Wright, Karen W.; Frankie, Gordon; Parker, Frank
2013-01-01
Recently there has been considerable concern about declines in bee communities in agricultural and natural habitats. The value of pollination to agriculture, provided primarily by bees, is >$200 billion/year worldwide, and in natural ecosystems it is thought to be even greater. However, no monitoring program exists to accurately detect declines in abundance of insect pollinators; thus, it is difficult to quantify the status of bee communities or estimate the extent of declines. We used data from 11 multiyear studies of bee communities to devise a program to monitor pollinators at regional, national, or international scales. In these studies, 7 different methods for sampling bees were used and bees were sampled on 3 different continents. We estimated that a monitoring program with 200-250 sampling locations each sampled twice over 5 years would provide sufficient power to detect small (2-5%) annual declines in the number of species and in total abundance and would cost U.S.$2,000,000. To detect declines as small as 1% annually over the same period would require >300 sampling locations. Given the role of pollinators in food security and ecosystem function, we recommend establishment of integrated regional and international monitoring programs to detect changes in pollinator communities.
Computer-aided Detection of Prostate Cancer with MRI: Technology and Applications.
Liu, Lizhi; Tian, Zhiqiang; Zhang, Zhenfeng; Fei, Baowei
2016-08-01
One in six men will develop prostate cancer in his lifetime. Early detection and accurate diagnosis of the disease can improve cancer survival and reduce treatment costs. Recently, imaging of prostate cancer has greatly advanced since the introduction of multiparametric magnetic resonance imaging (mp-MRI). Mp-MRI consists of T2-weighted sequences combined with functional sequences including dynamic contrast-enhanced MRI, diffusion-weighted MRI, and magnetic resonance spectroscopy imaging. Because of the big data and variations in imaging sequences, detection can be affected by multiple factors such as observer variability and visibility and complexity of the lesions. To improve quantitative assessment of the disease, various computer-aided detection systems have been designed to help radiologists in their clinical practice. This review paper presents an overview of literatures on computer-aided detection of prostate cancer with mp-MRI, which include the technology and its applications. The aim of the survey is threefold: an introduction for those new to the field, an overview for those working in the field, and a reference for those searching for literature on a specific application. Copyright © 2016 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.
VaDiR: an integrated approach to Variant Detection in RNA.
Neums, Lisa; Suenaga, Seiji; Beyerlein, Peter; Anders, Sara; Koestler, Devin; Mariani, Andrea; Chien, Jeremy
2018-02-01
Advances in next-generation DNA sequencing technologies are now enabling detailed characterization of sequence variations in cancer genomes. With whole-genome sequencing, variations in coding and non-coding sequences can be discovered. But the cost associated with it is currently limiting its general use in research. Whole-exome sequencing is used to characterize sequence variations in coding regions, but the cost associated with capture reagents and biases in capture rate limit its full use in research. Additional limitations include uncertainty in assigning the functional significance of the mutations when these mutations are observed in the non-coding region or in genes that are not expressed in cancer tissue. We investigated the feasibility of uncovering mutations from expressed genes using RNA sequencing datasets with a method called Variant Detection in RNA(VaDiR) that integrates 3 variant callers, namely: SNPiR, RVBoost, and MuTect2. The combination of all 3 methods, which we called Tier 1 variants, produced the highest precision with true positive mutations from RNA-seq that could be validated at the DNA level. We also found that the integration of Tier 1 variants with those called by MuTect2 and SNPiR produced the highest recall with acceptable precision. Finally, we observed a higher rate of mutation discovery in genes that are expressed at higher levels. Our method, VaDiR, provides a possibility of uncovering mutations from RNA sequencing datasets that could be useful in further functional analysis. In addition, our approach allows orthogonal validation of DNA-based mutation discovery by providing complementary sequence variation analysis from paired RNA/DNA sequencing datasets.
Plehn, Gunnar; Butz, Thomas; Maagh, Petra; Oernek, Ahmet; Meissner, Axel; Plehn, Natalie
2016-11-03
Cardiac catheterization laboratories (CLL) have continued to function as profit centers for hospitals. Due to a high percentage of material and labor costs, they are natural targets for process improvement. Our study applied a contribution margin (CBM) concept to evaluate costs and cost dynamics over a 5-year period. We retrospectively analyzed all procedures performed at a tertiary heart center between 2007 and 2011. Total variable costs, including labor time, material, and maintenance-expenses, were allocated at a global as well as a procedural level. CBM and CBM ratios were calculated by integration of individual DRG revenues. Annual case volume increased from 1288 to 1545. In parallel, overall profitability improved as indicated by a 2% increase in CBM ratio and a higher CBM generated per hour of CLL working time (4325 vs. 5892 €, p < 0.001). Coronary angiography generated higher average CBMs per hour than coronary or electrophysiological interventions (5831 vs. 3458 vs. 1495 €; p < 0.001). The latter are characterized by relatively high per case material expenditures. On a procedural level, DRG-specific trends as a steady improvement of examination time or an increase in material costs were detectable. The CBM concept allows a comprehensive analysis of CLL costs and cost dynamics. From a health service providers view, its range of application includes global profitability analysis, portfolio evaluation, and a detailed cost analysis of specific service lines. From a healthcare payers perspective, it may help to monitor hospital activities and to provide a solid data basis in cases where inappropriate developments are suspected. The calculation principle is simple which may increase user acceptance and thus the motivation of team members.
Wang, Hai-peng; Bi, Zheng-yang; Zhou, Yang; Zhou, Yu-xuan; Wang, Zhi-gong; Lv, Xiao-ying
2017-01-01
Voluntary participation of hemiplegic patients is crucial for functional electrical stimulation therapy. A wearable functional electrical stimulation system has been proposed for real-time volitional hand motor function control using the electromyography bridge method. Through a series of novel design concepts, including the integration of a detecting circuit and an analog-to-digital converter, a miniaturized functional electrical stimulation circuit technique, a low-power super-regeneration chip for wireless receiving, and two wearable armbands, a prototype system has been established with reduced size, power, and overall cost. Based on wrist joint torque reproduction and classification experiments performed on six healthy subjects, the optimized surface electromyography thresholds and trained logistic regression classifier parameters were statistically chosen to establish wrist and hand motion control with high accuracy. Test results showed that wrist flexion/extension, hand grasp, and finger extension could be reproduced with high accuracy and low latency. This system can build a bridge of information transmission between healthy limbs and paralyzed limbs, effectively improve voluntary participation of hemiplegic patients, and elevate efficiency of rehabilitation training. PMID:28250759
Vintzileos, A M; Ananth, C V; Fisher, A J; Smulian, J C; Day-Salvatore, D; Beazoglou, T; Knuppel, R A
1998-11-01
The objective of this study was to perform an economic evaluation of second-trimester genetic ultrasonography for prenatal detection of Down syndrome. More specifically, we sought to determine the following: (1) the diagnostic accuracy requirements (from the cost-benefit point of view) of genetic ultrasonography versus genetic amniocentesis for women at increased risk for fetal Down syndrome and (2) the possible economic impact of second-trimester genetic ultrasonography for the US population on the basis of the ultrasonographic accuracies reported in previously published studies. A cost-benefit equation was developed from the hypothesis that the cost of universal genetic amniocentesis of patients at increased risk for carrying a fetus with Down syndrome should be at least equal to the cost of universal genetic ultrasonography with amniocentesis used only for those with abnormal ultrasonographic results. The main components of the equation included the diagnostic accuracy of genetic ultrasonography (sensitivity and specificity for detecting Down syndrome), the costs of the amniocentesis package and genetic ultrasonography, and the lifetime cost of Down syndrome cases not detected by the genetic ultrasonography. After appropriate manipulation of the equation a graph was constructed, representing the balance between sensitivity and false-positive rate of genetic ultrasonography; this was used to examine the accuracy of previously published studies from the cost-benefit point of view. Sensitivity analyses included individual risks for Down syndrome ranging from 1:261 (risk of a 35-year-old at 18 weeks' gestation) to 1:44 (risk of a 44-year-old at 18 weeks' gestation). This economic evaluation was conducted from the societal perspective. Genetic ultrasonography was found to be economically beneficial only if the overall sensitivity for detecting Down syndrome was >74%. Even then, the cost-benefit ratio depended on the corresponding false-positive rate. Of the 7 published studies that used multiple ultrasonographic markers for genetic ultrasonography, 6 had accuracies compatible with benefits. The required ultrasonographic accuracy (sensitivity and false-positive rate) varied according to the prevalence of Down syndrome in the population tested. The cost-benefit ratio of second-trimester genetic ultrasonography depends on its diagnostic accuracy, and it is beneficial only when its overall sensitivity for Down syndrome is >74%.
Arnold, David T; Bentham, Louise M; Jacob, Ruth P; Lilford, Richard J; Girling, Alan J
2011-03-03
Liver function tests (LFTs) are ordered in large numbers in primary care, and the Birmingham and Lambeth Liver Evaluation Testing Strategies (BALLETS) study was set up to assess their usefulness in patients with no pre-existing or self-evident liver disease. All patients were tested for chronic viral hepatitis thereby providing an opportunity to compare various strategies for detection of this serious treatable disease. This study uses data from the BALLETS cohort to compare various testing strategies for viral hepatitis in patients who had received an abnormal LFT result. The aim was to inform a strategy for identification of patients with chronic viral hepatitis. We used a cost-minimisation analysis to define a base case and then calculated the incremental cost per case detected to inform a strategy that could guide testing for chronic viral hepatitis. Of the 1,236 study patients with an abnormal LFT, 13 had chronic viral hepatitis (nine hepatitis B and four hepatitis C). The strategy advocated by the current guidelines (repeating the LFT with a view to testing for specific disease if it remained abnormal) was less efficient (more expensive per case detected) than a simple policy of testing all patients for viral hepatitis without repeating LFTs. A more selective strategy of viral testing all patients for viral hepatitis if they were born in countries where viral hepatitis was prevalent provided high efficiency with little loss of sensitivity. A notably high alanine aminotransferase (ALT) level (greater than twice the upper limit of normal) on the initial ALT test had high predictive value, but was insensitive, missing half the cases of viral infection. Based on this analysis and on widely accepted clinical principles, a "fast and frugal" heuristic was produced to guide general practitioners with respect to diagnosing cases of viral hepatitis in asymptomatic patients with abnormal LFTs. It recommends testing all patients where a clear clinical indication of infection is present (e.g. evidence of intravenous drug use), followed by testing all patients who originated from countries where viral hepatitis is prevalent, and finally testing those who have a notably raised ALT level (more than twice the upper limit of normal). Patients not picked up by this efficient algorithm had a risk of chronic viral hepatitis that is lower than the general population.
Systematic review of the incremental costs of interventions that increase immunization coverage.
Ozawa, Sachiko; Yemeke, Tatenda T; Thompson, Kimberly M
2018-05-10
Achieving and maintaining high vaccination coverage requires investments, but the costs and effectiveness of interventions to increase coverage remain poorly characterized. We conducted a systematic review of the literature to identify peer-reviewed studies published in English that reported interventions aimed at increasing immunization coverage and the associated costs and effectiveness of the interventions. We found limited information in the literature, with many studies reporting effectiveness estimates, but not providing cost information. Using the available data, we developed a cost function to support future programmatic decisions about investments in interventions to increase immunization coverage for relatively low and high-income countries. The cost function estimates the non-vaccine cost per dose of interventions to increase absolute immunization coverage by one percent, through either campaigns or routine immunization. The cost per dose per percent increase in absolute coverage increased with higher baseline coverage, demonstrating increasing incremental costs required to reach higher coverage levels. Future studies should evaluate the performance of the cost function and add to the database of available evidence to better characterize heterogeneity in costs and generalizability of the cost function. Copyright © 2018. Published by Elsevier Ltd.
Rapid Isolation of Phenol Degrading Bacteria by Fourier Transform Infrared (FTIR) Spectroscopy.
Li, Fei; Song, Wen-jun; Wei, Ji-ping; Wang, Su-ying; Liu, Chong-ji
2015-05-01
Phenol is an important chemical engineering material and ubiquitous in industry wastewater, its existence has become a thorny issue in many developed and developing country. More and more stringent standards for effluent all over the world with human realizing the toxicity of phenol have been announced. Many advanced biological methods are applied to industrial wastewater treatment with low cost, high efficiency and no secondary pollution, but the screening of function microorganisms is certain cumbersome process. In our study a rapid procedure devised for screening bacteria on solid medium can degrade phenol coupled with attenuated total reflection fourier transform infrared (ATR-FTIR) which is a detection method has the characteristics of efficient, fast, high fingerprint were used. Principal component analysis (PCA) is a method in common use to extract fingerprint peaks effectively, it couples with partial least squares (PLS) statistical method could establish a credible model. The model we created using PCA-PLS can reach 99. 5% of coefficient determination and validation data get 99. 4%, which shows the promising fitness and forecasting of the model. The high fitting model is used for predicting the concentration of phenol at solid medium where the bacteria were grown. The highly consistent result of two screening methods, solid cultural with ATR-FTIR detected and traditional liquid cultural detected by GC methods, suggests the former can rapid isolate the bacteria which can degrade substrates as well as traditional cumbersome liquid cultural method. Many hazardous substrates widely existed in industry wastewater, most of them has specialize fingerprint peaks detected by ATR-FTIR, thereby this detected method could be used as a rapid detection for isolation of functional microorganisms those can degrade many other toxic substrates.
Electrical breakdown detection system for dielectric elastomer actuators
NASA Astrophysics Data System (ADS)
Ghilardi, Michele; Busfield, James J. C.; Carpi, Federico
2017-04-01
Electrical breakdown of dielectric elastomer actuators (DEAs) is an issue that has to be carefully addressed when designing systems based on this novel technology. Indeed, in some systems electrical breakdown might have serious consequences, not only in terms of interruption of the desired function but also in terms of safety of the overall system (e.g. overheating and even burning). The risk for electrical breakdown often cannot be completely avoided by simply reducing the driving voltages, either because completely safe voltages might not generate sufficient actuation or because internal or external factors might change some properties of the actuator whilst in operation (for example the aging or fatigue of the material, or an externally imposed deformation decreasing the distance between the compliant electrodes). So, there is the clear need for reliable, simple and cost-effective detection systems that are able to acknowledge the occurrence of a breakdown event, making DEA-based devices able to monitor their status and become safer and "selfaware". Here a simple solution for a portable detection system is reported that is based on a voltage-divider configuration that detects the voltage drop at the DEA terminals and assesses the occurrence of breakdown via a microcontroller (Beaglebone Black single-board computer) combined with a real-time, ultra-low-latency processing unit (Bela cape an open-source embedded platform developed at Queen Mary University of London). The system was used to both generate the control signal that drives the actuator and constantly monitor the functionality of the actuator, detecting any breakdown event and discontinuing the supplied voltage accordingly, so as to obtain a safer controlled actuation. This paper presents preliminary tests of the detection system in different scenarios in order to assess its reliability.
Rapid and label-free electrochemical DNA biosensor for detecting hepatitis A virus.
Manzano, Marisa; Viezzi, Sara; Mazerat, Sandra; Marks, Robert S; Vidic, Jasmina
2018-02-15
Diagnostic systems that can deliver highly specific and sensitive detection of hepatitis A virus (HAV) in food and water are of particular interest in many fields including food safety, biosecurity and control of outbreaks. Our aim was the development of an electrochemical method based on DNA hybridization to detect HAV. A ssDNA probe specific for HAV (capture probe) was designed and tested on DNAs from various viral and bacterial samples using Nested-Reverse Transcription Polymerase Chain Reaction (nRT-PCR). To develop the electrochemical device, a disposable gold electrode was functionalized with the specific capture probe and tested on complementary ssDNA and on HAV cDNA. The DNA hybridization on the electrode was measured through the monitoring of the oxidative peak potential of the indicator tripropylamine by cyclic voltammetry. To prevent non-specific binding the gold surface was treated with 3% BSA before detection. High resolution atomic force microscopy (AFM) confirmed the efficiency of electrode functionalization and on-electrode hybridization. The proposed device showed a limit of detection of 0.65pM for the complementary ssDNA and 6.94fg/µL for viral cDNA. For a comparison, nRT-PCR quantified the target HAV cDNA with a limit of detection of 6.4fg/µL. The DNA-sensor developed can be adapted to a portable format to be adopted as an easy-to- use and low cost method for screening HAV in contaminated food and water. In addition, it can be useful for rapid control of HAV infections as it takes only a few minutes to provide the results. Copyright © 2017. Published by Elsevier B.V.
Solving bezel reliability and CRT obsolescence
NASA Astrophysics Data System (ADS)
Schwartz, Richard J.; Bowen, Arlen R.; Knowles, Terry
2003-09-01
Scientific Research Corporation designed a Smart Multi-Function Color Display with Positive Pilot Feedback under the funding of an U. S. Navy Small Business Innovative Research program. The Smart Multi-Function Color Display can replace the obsolete monochrome Cathode Ray Tube display currently on the T-45C aircraft built by Boeing. The design utilizes a flat panel color Active Matrix Liquid Crystal Display and TexZec's patented Touch Thru Metal bezel technology providing both visual and biomechanical feedback to the pilot in a form, fit, and function replacement to the current T-45C display. Use of an existing color AMLCD, requires the least adaptation to fill the requirements of this application, thereby minimizing risk associated with developing a new display technology and maximizing the investment in improved user interface technology. The improved user interface uses TexZec's Touch Thru Metal technology to eliminate all of the moving parts that traditionally have limited Mean-Time-Between-Failure. The touch detection circuit consists of Commercial-Off-The-Shelf components, creating touch detection circuitry, which is simple and durable. This technology provides robust switch activation and a high level of environmental immunity, both mechanical and electrical. Replacement of all the T-45C multi-function displays with this design will improve the Mean-Time-Between-Failure and drastically reduce display life cycle costs. The design methodology described in this paper can be adapted to any new or replacement display.
Small unmanned aircraft system for remote contour mapping of a nuclear radiation field
NASA Astrophysics Data System (ADS)
Guss, Paul; McCall, Karen; Malchow, Russell; Fischer, Rick; Lukens, Michael; Adan, Mark; Park, Ki; Abbott, Roy; Howard, Michael; Wagner, Eric; Trainham, Clifford P.; Luke, Tanushree; Mukhopadhyay, Sanjoy; Oh, Paul; Brahmbhatt, Pareshkumar; Henderson, Eric; Han, Jinlu; Huang, Justin; Huang, Casey; Daniels, Jon
2017-09-01
For nuclear disasters involving radioactive contamination, small unmanned aircraft systems (sUASs) equipped with nuclear radiation detection and monitoring capability can be very important tools. Among the advantages of a sUAS are quick deployment, low-altitude flying that enhances sensitivity, wide area coverage, no radiation exposure health safety restriction, and the ability to access highly hazardous or radioactive areas. Additionally, the sUAS can be configured with the nuclear detecting sensor optimized to measure the radiation associated with the event. In this investigation, sUAS platforms were obtained for the installation of sensor payloads for radiation detection and electro-optical systems that were specifically developed for sUAS research, development, and operational testing. The sensor payloads were optimized for the contour mapping of a nuclear radiation field, which will result in a formula for low-cost sUAS platform operations with built-in formation flight control. Additional emphases of the investigation were to develop the relevant contouring algorithms; initiate the sUAS comprehensive testing using the Unmanned Systems, Inc. (USI) Sandstorm platforms and other acquired platforms; and both acquire and optimize the sensors for detection and localization. We demonstrated contour mapping through simulation and validated waypoint detection. We mounted a detector on a sUAS and operated it initially in the counts per second (cps) mode to perform field and flight tests to demonstrate that the equipment was functioning as designed. We performed ground truth measurements to determine the response of the detector as a function of source-to-detector distance. Operation of the radiation detector was tested using different unshielded sources.
Bhand, Sunil; Mishra, Geetesh K
2017-01-01
An electrochemical quartz crystal nanobalance (EQCN), which provides real-time analysis of dynamic surface events, is a valuable tool for analyzing biomolecular interactions. EQCN biosensors are based on mass-sensitive measurements that can detect small mass changes caused by chemical binding to small piezoelectric crystals. Among the various biosensors, the piezoelectric biosensor is considered one of the most sensitive analytical techniques, capable of detecting antigens at picogram levels. EQCN is an effective monitoring technique for regulation of the antibiotics below the maximum residual limit (MRL). The analysis of antibiotic residues requires high sensitivity, rapidity, reliability and cost effectiveness. For analytical purposes the general approach is to take advantage of the piezoelectric effect by immobilizing a biosensing layer on top of the piezoelectric crystal. The sensing layer usually comprises a biological material such as an antibody, enzymes, or aptamers having high specificity and selectivity for the target molecule to be detected. The biosensing layer is usually functionalized using surface chemistry modifications. When these bio-functionalized quartz crystals are exposed to a particular substance of interest (e.g., a substrate, inhibitor, antigen or protein), binding interaction occurs. This causes a frequency or mass change that can be used to determine the amount of material interacted or bound. EQCN biosensors can easily be automated by using a flow injection analysis (FIA) setup coupled through automated pumps and injection valves. Such FIA-EQCN biosensors have great potential for the detection of different analytes such as antibiotic residues in various matrices such as water, waste water, and milk.
Integrated immunoassay using tuneable surface acoustic waves and lensfree detection.
Bourquin, Yannyk; Reboud, Julien; Wilson, Rab; Zhang, Yi; Cooper, Jonathan M
2011-08-21
The diagnosis of infectious diseases in the Developing World is technologically challenging requiring complex biological assays with a high analytical performance, at minimal cost. By using an opto-acoustic immunoassay technology, integrating components commonly used in mobile phone technologies, including surface acoustic wave (SAW) transducers to provide pressure driven flow and a CMOS camera to enable lensfree detection technique, we demonstrate the potential to produce such an assay. To achieve this, antibody functionalised microparticles were manipulated on a low-cost disposable cartridge using the surface acoustic waves and were then detected optically. Our results show that the biomarker, interferon-γ, used for the diagnosis of diseases such as latent tuberculosis, can be detected at pM concentrations, within a few minutes (giving high sensitivity at a minimal cost). This journal is © The Royal Society of Chemistry 2011
Gordon, Louisa G; Brynes, Joshua; Baade, Peter D; Neale, Rachel E; Whiteman, David C; Youl, Philippa H; Aitken, Joanne F; Janda, Monika
2017-04-01
To assess the cost-effectiveness of an educational intervention encouraging self-skin examinations for early detection of skin cancers among men older than 50 years. A lifetime Markov model was constructed to combine data from the Skin Awareness Trial and other published sources. The model incorporated a health system perspective and the cost and health outcomes for melanoma, squamous and basal cell carcinomas, and benign skin lesions. Key model outcomes included Australian costs (2015), quality-adjusted life-years (QALYs), life-years, and counts of skin cancers. Univariate and probabilistic sensitivity analyses were undertaken to address parameter uncertainty. The mean cost of the intervention was A$5,298 compared with A$4,684 for usual care, whereas mean QALYs were 7.58 for the intervention group and 7.77 for the usual care group. The intervention was thus inferior to usual care. When only survival gain is considered, the model predicted the intervention would cost A$1,059 per life-year saved. The likelihood that the intervention was cost-effective up to A$50,000 per QALY gained was 43.9%. The model was stable to most data estimates; nevertheless, it relies on the specificity of clinical diagnosis of skin cancers and is subject to limited health utility data for people with skin lesions. Although the intervention improved skin checking behaviors and encouraged men to seek medical advice about suspicious lesions, the overall costs and effects from also detecting more squamous and basal cell carcinomas and benign lesions outweighed the positive health gains from detecting more thin melanomas. Copyright © 2017 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.
Chen, Liang; Huang, Linzhou; Min, Donghong; Phillips, Andy; Wang, Shiqiang; Madgwick, Pippa J; Parry, Martin A J; Hu, Yin-Gang
2012-01-01
Mutagenesis is an important tool in crop improvement. However, the hexaploid genome of wheat (Triticum aestivum L.) presents problems in identifying desirable genetic changes based on phenotypic screening due to gene redundancy. TILLING (Targeting Induced Local Lesions IN Genomes), a powerful reverse genetic strategy that allows the detection of induced point mutations in individuals of the mutagenized populations, can address the major challenge of linking sequence information to the biological function of genes and can also identify novel variation for crop breeding. Wheat is especially well-suited for TILLING due to the high mutation densities tolerated by polyploids. However, only a few wheat TILLING populations are currently available in the world, which is far from satisfying the requirement of researchers and breeders in different growing environments. In addition, current TILLING screening protocols require costly fluorescence detection systems, limiting their use, especially in developing countries. We developed a new TILLING resource comprising 2610 M(2) mutants in a common wheat cultivar 'Jinmai 47'. Numerous phenotypes with altered morphological and agronomic traits were observed from the M(2) and M(3) lines in the field. To simplify the procedure and decrease costs, we use unlabeled primers and either non-denaturing polyacrylamide gels or agarose gels for mutation detection. The value of this new resource was tested using PCR with RAPD and Intron-spliced junction (ISJ) primers, and also TILLING in three selected candidate genes, in 300 and 512 mutant lines, revealing high mutation densities of 1/34 kb by RAPD/ISJ analysis and 1/47 kb by TILLING. In total, 31 novel alleles were identified in the 3 targeted genes and confirmed by sequencing. The results indicate that this mutant population represents a useful resource for the wheat research community. We hope that the use of this reverse genetics resource will provide novel allelic diversity for wheat improvement and functional genomics.
NASA Technical Reports Server (NTRS)
DeBoer, Gary D.
2005-01-01
Carbon nanotubes hold great promise for material advancements in the areas of composites and electronics. The advancement of research in these areas is dependent upon the availability of carbon nanotubes to a broad spectrum of academic and industrial researchers. Although there has been much progress made in reducing the costs of carbon nanotubes and increasing the quality and purity of the products, an increase in demand for still less expensive and specific nanotubes types has also grown. This summer's work has involved two experiments that have been designed to further the understanding of the dynamics and chemical mechanisms of carbon nanotube formation. It is expected that a better understanding of the process of formation of nanotubes will aid current production designs and stimulate ideas for future production designs increasing the quantity, quality, and production control of carbon nanotubes. The first experiment involved the measurement of surface temperature of the target as a function of time with respect to the ablation lasers. A peak surface temperature of 5000 K was determined from spectral analysis of black body emission from the target surface. The surface temperature as a function of various changes in operating parameters was also obtained. This data is expected to aid the modeling of ablation and plume dynamics. The second experiment involved a time and spatial measurement of the spectrally resolved absorbance of the laser produced plume. This experiment explored the possibility of developing absorbance and fluorescence to detect carbon nanotubes during production. To attain control over the production of nanotubes with specific properties and reduce costs, a real time in situ diagnostics method would be very beneficial. Results from this summer's work indicate that detection of nanotubes during production may possibly be used for production feed back control.
NASA Astrophysics Data System (ADS)
Ranamukhaarachchi, Sahan A.; Padeste, Celestino; Dübner, Matthias; Häfeli, Urs O.; Stoeber, Boris; Cadarso, Victor J.
2016-07-01
Therapeutic drug monitoring (TDM) typically requires painful blood drawn from patients. We propose a painless and minimally-invasive alternative for TDM using hollow microneedles suitable to extract extremely small volumes (<1 nL) of interstitial fluid to measure drug concentrations. The inner lumen of a microneedle is functionalized to be used as a micro-reactor during sample collection to trap and bind target drug candidates during extraction, without requirements of sample transfer. An optofluidic device is integrated with this microneedle to rapidly quantify drug analytes with high sensitivity using a straightforward absorbance scheme. Vancomycin is currently detected by using volumes ranging between 50-100 μL with a limit of detection (LoD) of 1.35 μM. The proposed microneedle-optofluidic biosensor can detect vancomycin with a sample volume of 0.6 nL and a LoD of <100 nM, validating this painless point of care system with significant potential to reduce healthcare costs and patients suffering.
Multisensor system for toxic gases detection generated on indoor environments
NASA Astrophysics Data System (ADS)
Durán, C. M.; Monsalve, P. A. G.; Mosquera, C. J.
2016-11-01
This work describes a wireless multisensory system for different toxic gases detection generated on indoor environments (i.e., Underground coal mines, etc.). The artificial multisensory system proposed in this study was developed through a set of six chemical gas sensors (MQ) of low cost with overlapping sensitivities to detect hazardous gases in the air. A statistical parameter was implemented to the data set and two pattern recognition methods such as Principal Component Analysis (PCA) and Discriminant Function Analysis (DFA) were used for feature selection. The toxic gases categories were classified with a Probabilistic Neural Network (PNN) in order to validate the results previously obtained. The tests were carried out to verify feasibility of the application through a wireless communication model which allowed to monitor and store the information of the sensor signals for the appropriate analysis. The success rate in the measures discrimination was 100%, using an artificial neural network where leave-one-out was used as cross validation method.
Electrophoretic mobility shift scanning using an automated infrared DNA sequencer.
Sano, M; Ohyama, A; Takase, K; Yamamoto, M; Machida, M
2001-11-01
Electrophoretic mobility shift assay (EMSA) is widely used in the study of sequence-specific DNA-binding proteins, including transcription factors and mismatch binding proteins. We have established a non-radioisotope-based protocol for EMSA that features an automated DNA sequencer with an infrared fluorescent dye (IRDye) detection unit. Our modification of the elec- trophoresis unit, which includes cooling the gel plates with a reduced well-to-read length, has made it possible to detect shifted bands within 1 h. Further, we have developed a rapid ligation-based method for generating IRDye-labeled probes with an approximately 60% cost reduction. This method has the advantages of real-time scanning, stability of labeled probes, and better safety associated with nonradioactive methods of detection. Analysis of a promoter from an industrially important filamentous fungus, Aspergillus oryzae, in a prototype experiment revealed that the method we describe has potential for use in systematic scanning and identification of the functionally important elements to which cellular factors bind in a sequence-specific manner.
Practical Considerations for Optic Nerve Estimation in Telemedicine
DOE Office of Scientific and Technical Information (OSTI.GOV)
Karnowski, Thomas Paul; Aykac, Deniz; Chaum, Edward
The projected increase in diabetes in the United States and worldwide has created a need for broad-based, inexpensive screening for diabetic retinopathy (DR), an eye disease which can lead to vision impairment. A telemedicine network with retina cameras and automated quality control, physiological feature location, and lesion / anomaly detection is a low-cost way of achieving broad-based screening. In this work we report on the effect of quality estimation on an optic nerve (ON) detection method with a confidence metric. We report on an improvement of the fusion technique using a data set from an ophthalmologists practice then show themore » results of the method as a function of image quality on a set of images from an on-line telemedicine network collected in Spring 2009 and another broad-based screening program. We show that the fusion method, combined with quality estimation processing, can improve detection performance and also provide a method for utilizing a physician-in-the-loop for images that may exceed the capabilities of automated processing.« less
Ranamukhaarachchi, Sahan A.; Padeste, Celestino; Dübner, Matthias; Häfeli, Urs O.; Stoeber, Boris; Cadarso, Victor J.
2016-01-01
Therapeutic drug monitoring (TDM) typically requires painful blood drawn from patients. We propose a painless and minimally-invasive alternative for TDM using hollow microneedles suitable to extract extremely small volumes (<1 nL) of interstitial fluid to measure drug concentrations. The inner lumen of a microneedle is functionalized to be used as a micro-reactor during sample collection to trap and bind target drug candidates during extraction, without requirements of sample transfer. An optofluidic device is integrated with this microneedle to rapidly quantify drug analytes with high sensitivity using a straightforward absorbance scheme. Vancomycin is currently detected by using volumes ranging between 50–100 μL with a limit of detection (LoD) of 1.35 μM. The proposed microneedle-optofluidic biosensor can detect vancomycin with a sample volume of 0.6 nL and a LoD of <100 nM, validating this painless point of care system with significant potential to reduce healthcare costs and patients suffering. PMID:27380889
NASA Astrophysics Data System (ADS)
Maass, Bolko
2016-12-01
This paper describes an efficient and easily implemented algorithmic approach to extracting an approximation to an image's dominant projected illumination direction, based on intermediary results from a segmentation-based crater detection algorithm (CDA), at a computational cost that is negligible in comparison to that of the prior stages of the CDA. Most contemporary CDAs built for spacecraft navigation use this illumination direction as a means of improving performance or even require it to function at all. Deducing the illumination vector from the image alone reduces the reliance on external information such as the accurate knowledge of the spacecraft inertial state, accurate time base and solar system ephemerides. Therefore, a method such as the one described in this paper is a prerequisite for true "Lost in Space" operation of a purely segmentation-based crater detecting and matching method for spacecraft navigation. The proposed method is verified using ray-traced lunar elevation model data, asteroid image data, and in a laboratory setting with a camera in the loop.
Cost Efficiency in Public Higher Education.
ERIC Educational Resources Information Center
Robst, John
This study used the frontier cost function framework to examine cost efficiency in public higher education. The frontier cost function estimates the minimum predicted cost for producing a given amount of output. Data from the annual Almanac issues of the "Chronicle of Higher Education" were used to calculate state level enrollments at two-year and…
Meroni, E; Bisagni, P; Bona, S; Fumagalli, U; Zago, M; Rosati, R; Malesci, A
2004-01-01
Pre-operative endosonography has been proposed as a cost-effective procedure in the management of patients who undergo laparoscopic cholecystectomy having an intermediate risk of common bile duct stones. We prospectively evaluated the impact of pre-operative endosonography on the management of patients facing laparoscopic cholecystectomy with abnormal liver function tests as the sole risk factor for choledocolithiasis. Among 587 consecutive patients scheduled for laparoscopic cholecystectomy, 47 (8%) patients having one or more abnormal liver function tests but a normal appearance of common bile duct at abdominal ultrasound, underwent pre-operative endosonography. In patients with endosonography-detected common bile duct stones, a pre-operative endoscopic retrograde cholangiography was performed, or an intra-operative endoscopic retrograde cholangiography was scheduled. In all endosonography-negative patients, an intra-operative trans-cystic cholangiography was performed. Endosonography detected common bile duct stones in nine patients (19%) but only in five of them stones were radiologically confirmed (PPV 0.55). Endosonography-detected stones were confirmed in four of four (100%) patients in whom cholangiography was performed within 1 week, but only in one of five (20%) patients in whom radiology was further delayed (P < 0.05). In three of four cases (75%), stones detected at endosonography but not confirmed at X-rays, were smaller than 2.0 mm. Among 38 patients with negative endosonography, common bile duct stones were found in two patients (NPV 0.95), whereas unplanned endoscopic stone extraction was needed only in one patient (NPV 0.97). Pre-operative endosonography can spare unnecessary pre-operative endoscopic retrograde cholangiography as well as inappropriate scheduling of intra-operative endoscopic retrograde cholangiography in patients undergoing laparoscopic cholecystectomy with abnormal liver function tests. To maximise the impact of endosonography on the management of these patients, the procedure should be performed immediately before laparoscopic cholecystectomy.
Yu, Xiuxia; He, Yi; Jiang, Jie; Cui, Hua
2014-02-17
Chloramphenicol (CHL) as a broad-spectrum antibiotic has a broad action spectrum against Gram-positive and Gram-negative bacteria, as well as anaerobes. The use of CHL is strictly restricted in poultry because of its toxic effect. However, CHL is still illegally used in animal farming because of its accessibility and low cost. Therefore, sensitive methods are highly desired for the determination of CHL in foodstuffs. The immunoassays based on labeling as an important tool have been reported for the detection of CHL residues in food-producing animals. However, most of the labeling procedures require multi-step reactions and purifications and thus they are complicated and time-consuming. Recently, in our previous work, luminol functionalized silver nanoparticles have been successfully synthesized, which exhibits higher CL efficiency than luminol functionalized gold nanoparticles. In this work, the new luminol functionalized silver nanoparticles have been used for the labeling of small molecules CHL for the first time and a competitive chemiluminescent immunoassay has been developed for the detection of CHL. Owing to the amplification of silver nanoparticles, high sensitivity for CHL could be achieved with a low detection limit of 7.6×10(-9) g mL(-1) and a wide linear dynamic range of 1.0×10(-8)-1.0×10(-6) g mL(-1). This method has also been successfully applied to determine CHL in milk and honey samples with a good recoveries (92% and 102%, 99% and 107% respectively), indicating that the method is feasible for the determination of CHL in real milk and honey samples. The labeling procedure is simple, convenient and fast, superior to previously reported labeling procedures. The immunoassay is also simple, fast, sensitive and selective. It is of application potential for the determination of CHL in foodstuffs. Copyright © 2014 Elsevier B.V. All rights reserved.
A spatially explicit capture-recapture estimator for single-catch traps.
Distiller, Greg; Borchers, David L
2015-11-01
Single-catch traps are frequently used in live-trapping studies of small mammals. Thus far, a likelihood for single-catch traps has proven elusive and usually the likelihood for multicatch traps is used for spatially explicit capture-recapture (SECR) analyses of such data. Previous work found the multicatch likelihood to provide a robust estimator of average density. We build on a recently developed continuous-time model for SECR to derive a likelihood for single-catch traps. We use this to develop an estimator based on observed capture times and compare its performance by simulation to that of the multicatch estimator for various scenarios with nonconstant density surfaces. While the multicatch estimator is found to be a surprisingly robust estimator of average density, its performance deteriorates with high trap saturation and increasing density gradients. Moreover, it is found to be a poor estimator of the height of the detection function. By contrast, the single-catch estimators of density, distribution, and detection function parameters are found to be unbiased or nearly unbiased in all scenarios considered. This gain comes at the cost of higher variance. If there is no interest in interpreting the detection function parameters themselves, and if density is expected to be fairly constant over the survey region, then the multicatch estimator performs well with single-catch traps. However if accurate estimation of the detection function is of interest, or if density is expected to vary substantially in space, then there is merit in using the single-catch estimator when trap saturation is above about 60%. The estimator's performance is improved if care is taken to place traps so as to span the range of variables that affect animal distribution. As a single-catch likelihood with unknown capture times remains intractable for now, researchers using single-catch traps should aim to incorporate timing devices with their traps.
Defining and reconstructing clinical processes based on IHE and BPMN 2.0.
Strasser, Melanie; Pfeifer, Franz; Helm, Emmanuel; Schuler, Andreas; Altmann, Josef
2011-01-01
This paper describes the current status and the results of our process management system for defining and reconstructing clinical care processes, which contributes to compare, analyze and evaluate clinical processes and further to identify high cost tasks or stays. The system is founded on IHE, which guarantees standardized interfaces and interoperability between clinical information systems. At the heart of the system there is BPMN, a modeling notation and specification language, which allows the definition and execution of clinical processes. The system provides functionality to define healthcare information system independent clinical core processes and to execute the processes in a workflow engine. Furthermore, the reconstruction of clinical processes is done by evaluating an IHE audit log database, which records patient movements within a health care facility. The main goal of the system is to assist hospital operators and clinical process managers to detect discrepancies between defined and actual clinical processes and as well to identify main causes of high medical costs. Beyond that, the system can potentially contribute to reconstruct and improve clinical processes and enhance cost control and patient care quality.
A feasibility study of colorectal cancer diagnosis via circulating tumor DNA derived CNV detection.
Molparia, Bhuvan; Oliveira, Glenn; Wagner, Jennifer L; Spencer, Emily G; Torkamani, Ali
2018-01-01
Circulating tumor DNA (ctDNA) has shown great promise as a biomarker for early detection of cancer. However, due to the low abundance of ctDNA, especially at early stages, it is hard to detect at high accuracies while keeping sequencing costs low. Here we present a pilot stage study to detect large scale somatic copy numbers variations (CNVs), which contribute more molecules to ctDNA signal compared to point mutations, via cell free DNA sequencing. We show that it is possible to detect somatic CNVs in early stage colorectal cancer (CRC) patients and subsequently discriminate them from normal patients. With 25 normal and 24 CRC samples, we achieve 100% specificity (lower bound confidence interval: 86%) and ~79% sensitivity (95% confidence interval: 63% - 95%,), though the performance should be considered with caution given the limited sample size. We report a lack of concordance between the CNVs detected via cfDNA sequencing and CNVs identified in parent tissue samples. However, recent findings suggest that a lack of concordance is expected for CNVs in CRC because of their sub-clonal nature. Finally, the CNVs we detect very likely contribute to cancer progression as they lie in functionally important regions, and have been shown to be associated with CRC specifically. This study paves the path for a larger scale exploration of the potential of CNV detection for both diagnoses and prognoses of cancer.
A low-cost FMCW radar for footprint detection from a mobile platform
NASA Astrophysics Data System (ADS)
Boutte, David; Taylor, Paul; Hunt, Allan
2015-05-01
Footprint and human trail detection in rugged all-weather environments is an important and challenging problem for perimeter security, passive surveillance and reconnaissance. To address this challenge a low-cost, wideband, frequency-modulated continuous wave (FMCW) radar operating at 33.4GHz - 35.5GHz is being developed through a Department of Homeland Security Science and Technology Directorate Phase I SBIR and has been experimentally demonstrated to be capable of detecting footprints and footprint trails on unimproved roads in an experimental setting. It uses a low-cost digital signal processor (DSP) that makes important operating parameters reconfigurable and allows for frequency sweep linearization, a key technique developed to increase footprint signal-to-noise ratio (SNR). This paper discusses the design, DSP implementation and experimental results of a low-cost FMCW radar for mobile footprint detection. A technique for wideband sweep linearization is detailed along with system performance metrics and experimental results showing receive-SNR from footprint trails in sand and on unimproved dirt roads. Results from a second stepped frequency CW (SFCW) Ka-band system are also shown, verifying the ability of both systems to detect footprints and footprint trails in an experimental setting. The results show that there is sufficient receive-SNR to detect even shallow footprints (~1cm) using a radar based detection system in Ka-band. Field experimental results focus on system proof of concept from a static position with mobile results also presented highlighting necessary improvements to both systems.
Face recognition system for set-top box-based intelligent TV.
Lee, Won Oh; Kim, Yeong Gon; Hong, Hyung Gil; Park, Kang Ryoung
2014-11-18
Despite the prevalence of smart TVs, many consumers continue to use conventional TVs with supplementary set-top boxes (STBs) because of the high cost of smart TVs. However, because the processing power of a STB is quite low, the smart TV functionalities that can be implemented in a STB are very limited. Because of this, negligible research has been conducted regarding face recognition for conventional TVs with supplementary STBs, even though many such studies have been conducted with smart TVs. In terms of camera sensors, previous face recognition systems have used high-resolution cameras, cameras with high magnification zoom lenses, or camera systems with panning and tilting devices that can be used for face recognition from various positions. However, these cameras and devices cannot be used in intelligent TV environments because of limitations related to size and cost, and only small, low cost web-cameras can be used. The resulting face recognition performance is degraded because of the limited resolution and quality levels of the images. Therefore, we propose a new face recognition system for intelligent TVs in order to overcome the limitations associated with low resource set-top box and low cost web-cameras. We implement the face recognition system using a software algorithm that does not require special devices or cameras. Our research has the following four novelties: first, the candidate regions in a viewer's face are detected in an image captured by a camera connected to the STB via low processing background subtraction and face color filtering; second, the detected candidate regions of face are transmitted to a server that has high processing power in order to detect face regions accurately; third, in-plane rotations of the face regions are compensated based on similarities between the left and right half sub-regions of the face regions; fourth, various poses of the viewer's face region are identified using five templates obtained during the initial user registration stage and multi-level local binary pattern matching. Experimental results indicate that the recall; precision; and genuine acceptance rate were about 95.7%; 96.2%; and 90.2%, respectively.
Yang, Zhanjun; Zong, Chen; Ju, Huangxian; Yan, Feng
2011-11-07
A streptavidin functionalized capillary immune microreactor was designed for highly efficient flow-through chemiluminescent (CL) immunoassay. The functionalized capillary could be used as both a support for highly efficient immobilization of antibody and a flow cell for flow-through immunoassay. The functionalized inner wall and the capture process were characterized using scanning electron microscopy. Compared to conventional packed tube or thin-layer cell immunoreactor, the proposed microreactor showed remarkable properties such as lower cost, simpler fabrication, better practicality and wider dynamic range for fast CL immunoassay with good reproducibility and stability. Using α-fetoprotein as model analyte, the highly efficient CL flow-through immunoassay system showed a linear range of 3 orders of magnitude from 0.5 to 200 ng mL(-1) and a low detection limit of 0.1 ng mL(-1). The capillary immune microreactor could make up the shortcoming of conventional CL immunoreactors and provided a promising alternative for highly efficient flow-injection immunoassay. Copyright © 2011 Elsevier B.V. All rights reserved.
Milanesi, P; Holderegger, R; Bollmann, K; Gugerli, F; Zellweger, F
2017-02-01
Estimating connectivity among fragmented habitat patches is crucial for evaluating the functionality of ecological networks. However, current estimates of landscape resistance to animal movement and dispersal lack landscape-level data on local habitat structure. Here, we used a landscape genetics approach to show that high-fidelity habitat structure maps derived from Light Detection and Ranging (LiDAR) data critically improve functional connectivity estimates compared to conventional land cover data. We related pairwise genetic distances of 128 Capercaillie (Tetrao urogallus) genotypes to least-cost path distances at multiple scales derived from land cover data. Resulting β values of linear mixed effects models ranged from 0.372 to 0.495, while those derived from LiDAR ranged from 0.558 to 0.758. The identification and conservation of functional ecological networks suffering from habitat fragmentation and homogenization will thus benefit from the growing availability of detailed and contiguous data on three-dimensional habitat structure and associated habitat quality. © 2016 by the Ecological Society of America.
NASA Astrophysics Data System (ADS)
Guérin, Joris; Gibaru, Olivier; Thiery, Stéphane; Nyiri, Eric
2017-01-01
Recent methods of Reinforcement Learning have enabled to solve difficult, high dimensional, robotic tasks under unknown dynamics using iterative Linear Quadratic Gaussian control theory. These algorithms are based on building a local time-varying linear model of the dynamics from data gathered through interaction with the environment. In such tasks, the cost function is often expressed directly in terms of the state and control variables so that it can be locally quadratized to run the algorithm. If the cost is expressed in terms of other variables, a model is required to compute the cost function from the variables manipulated. We propose a method to learn the cost function directly from the data, in the same way as for the dynamics. This way, the cost function can be defined in terms of any measurable quantity and thus can be chosen more appropriately for the task to be carried out. With our method, any sensor information can be used to design the cost function. We demonstrate the efficiency of this method through simulating, with the V-REP software, the learning of a Cartesian positioning task on several industrial robots with different characteristics. The robots are controlled in joint space and no model is provided a priori. Our results are compared with another model free technique, consisting in writing the cost function as a state variable.
van Es, Pauline P; Luijsterburg, Pim A J; Dekker, Joost; Koopmanschap, Marc A; Bohnen, Arthur M; Verhaar, Jan A N; Koes, Bart W; Bierma-Zeinstra, Sita M A
2011-10-12
Osteoarthritis (OA) is the most common joint disease, causing pain and functional impairments. According to international guidelines, exercise therapy has a short-term effect in reducing pain/functional impairments in knee OA and is therefore also generally recommended for hip OA. Because of its high prevalence and clinical implications, OA is associated with considerable (healthcare) costs. However, studies evaluating cost-effectiveness of common exercise therapy in hip OA are lacking. Therefore, this randomised controlled trial is designed to investigate the cost-effectiveness of exercise therapy in conjunction with the general practitioner's (GP) care, compared to GP care alone, for patients with hip OA. Patients aged ≥ 45 years with OA of the hip, who consulted the GP during the past year for hip complaints and who comply with the American College of Rheumatology criteria, are included. Patients are randomly assigned to either exercise therapy in addition to GP care, or to GP care alone. Exercise therapy consists of (maximally) 12 treatment sessions with a physiotherapist, and home exercises. These are followed by three additional treatment sessions in the 5th, 7th and 9th month after the first treatment session. GP care consists of usual care for hip OA, such as general advice or prescribing pain medication. Primary outcomes are hip pain and hip-related activity limitations (measured with the Hip disability Osteoarthritis Outcome Score [HOOS]), direct costs, and productivity costs (measured with the PROductivity and DISease Questionnaire). These parameters are measured at baseline, at 6 weeks, and at 3, 6, 9 and 12 months follow-up. To detect a 25% clinical difference in the HOOS pain score, with a power of 80% and an alpha 5%, 210 patients are required. Data are analysed according to the intention-to-treat principle. Effectiveness is evaluated using linear regression models with repeated measurements. An incremental cost-effectiveness analysis and an incremental cost-utility analysis will also be performed. The results of this trial will provide insight into the cost-effectiveness of adding exercise therapy to GPs' care in the treatment of OA of the hip. This trial is registered in the Dutch trial registry http://www.trialregister.nl: trial number NTR1462.
Morán López, Jesús Manuel; Piedra León, María; Beneítez Moralejo, Belén; Enciso Izquierdo, Fidel Jesús; Luengo Pérez, Luis Miguel; Amado Señaris, José Antonio
2016-06-01
Disease Related Malnutrition (DRM) is highly prevalent in Spanish hospitals. WHO estimates that 20-40% of health-associated expenses are lost due to inefficiency. Demonstration that DRM is a component of inefficiency and hiring a specialist physician for its detection and treatment is cost-effective. Comparison between nutritional diagnosis and procedures detected and encoded at discharge using McNemar test. Recoding of 162 discharge reports including nutritional diagnoses and procedures. Determine changes on Case-Mix Index (IC), cost of procedure and cost procedure/DRG index. Comparison using T-student paired test. Only 10 of 162 diagnoses of malnutrition were coded in delivery statements (p < 0.001). After right codification, IC increased in 103,3 DRG points (p < 0.001). Consequently, procedure cost/DRG index was reduced in 978.81 € (p < 0.001). DRM is underdiagnosed in our hospital. DRM and nutritional procedures detection by a doctor specialist in clinical nutrition led to a reduction in cost procedure/DRG index of 16.8% of officially established by the Health System. Loss of 16.8% of health expenses, estimated in 424.785,15 € was described. Proper codification would have justified 343.291,2 € reimbursement just for nutritional diagnoses and processes. Both expenses were lost due to system's inefficiency. Those amounts are much higher than cost associated of hiring a specialist in clinical nutrition. Copyright © 2016 European Society for Clinical Nutrition and Metabolism. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Teeples, Ronald; Glyer, David
1987-05-01
Both policy and technical analysis of water delivery systems have been based on cost functions that are inconsistent with or are incomplete representations of the neoclassical production functions of economics. We present a full-featured production function model of water delivery which can be estimated from a multiproduct, dual cost function. The model features implicit prices for own-water inputs and is implemented as a jointly estimated system of input share equations and a translog cost function. Likelihood ratio tests are performed showing that a minimally constrained, full-featured production function is a necessary specification of the water delivery operations in our sample. This, plus the model's highly efficient and economically correct parameter estimates, confirms the usefulness of a production function approach to modeling the economic activities of water delivery systems.
Dobhal, S; Zhang, G; Rohla, C; Smith, M W; Ma, L M
2014-10-01
PCR is widely used in the routine detection of foodborne human pathogens; however, challenges remain in overcoming PCR inhibitors present in some sample matrices. The objective of this study was to develop a simple, sensitive, cost-effective and rapid method for processing large numbers of environmental and pecan samples for Salmonella detection. This study was also aimed at validation of a new protocol for the detection of Salmonella from in-shell pecans. Different DNA template preparation methods, including direct boiling, prespin, multiple washing and commercial DNA extraction kits, were evaluated with pure cultures of Salmonella Typhimurium and with enriched soil, cattle feces and in-shell pecan each spiked individually with Salmonella Typhimurium. PCR detection of Salmonella was conducted using invA and 16S rRNA gene (internal amplification control) specific primers. The effect of amplification facilitators, including bovine serum albumin (BSA), polyvinylpyrrolidone (PVP), polyethylene glycol (PEG) and gelatin on PCR sensitivity, was also evaluated. Conducting a prespin of sample matrices in combination with the addition of 0·4% (w/v) BSA and 1% (w/v) PVP in PCR mix was the simplest, most rapid, cost-effective and sensitive method for PCR detection of Salmonella, with up to 40 CFU Salmonella per reaction detectable in the presence of over 10(9 ) CFU ml(-1) of background micro-organisms from enriched feces soil or pecan samples. The developed method is rapid, cost-effective and sensitive for detection of Salmonella from different matrices. This study provides a method with broad applicability for PCR detection of Salmonella in complex sample matrices. This method has a potential for its application in different research arenas and diagnostic laboratories. © 2014 The Society for Applied Microbiology.
A new passive sampling method with rapid low-cost spectral detection has recently been developed. The method makes use of an ultraviolet (UV)-transparent polymer which serves as both a concentrator for dissolved compounds, and an optical cell for UV spectral detection. Because ...
Lin, Xiaodong; Deng, Jiankang; Lyu, Yanlong; Qian, Pengcheng; Li, Yunfei
2018-01-01
The integration of multiple DNA logic gates on a universal platform to implement advance logic functions is a critical challenge for DNA computing. Herein, a straightforward and powerful strategy in which a guanine-rich DNA sequence lighting up a silver nanocluster and fluorophore was developed to construct a library of logic gates on a simple DNA-templated silver nanoclusters (DNA-AgNCs) platform. This library included basic logic gates, YES, AND, OR, INHIBIT, and XOR, which were further integrated into complex logic circuits to implement diverse advanced arithmetic/non-arithmetic functions including half-adder, half-subtractor, multiplexer, and demultiplexer. Under UV irradiation, all the logic functions could be instantly visualized, confirming an excellent repeatability. The logic operations were entirely based on DNA hybridization in an enzyme-free and label-free condition, avoiding waste accumulation and reducing cost consumption. Interestingly, a DNA-AgNCs-based multiplexer was, for the first time, used as an intelligent biosensor to identify pathogenic genes, E. coli and S. aureus genes, with a high sensitivity. The investigation provides a prototype for the wireless integration of multiple devices on even the simplest single-strand DNA platform to perform diverse complex functions in a straightforward and cost-effective way. PMID:29675221
Riedel, Timothy E; Zimmer-Faust, Amity G; Thulsiraj, Vanessa; Madi, Tania; Hanley, Kaitlyn T; Ebentier, Darcy L; Byappanahalli, Muruleedhara; Layton, Blythe; Raith, Meredith; Boehm, Alexandria B; Griffith, John F; Holden, Patricia A; Shanks, Orin C; Weisberg, Stephen B; Jay, Jennifer A
2014-04-01
Some molecular methods for tracking fecal pollution in environmental waters have both PCR and quantitative PCR (qPCR) assays available for use. To assist managers in deciding whether to implement newer qPCR techniques in routine monitoring programs, we compared detection limits (LODs) and costs of PCR and qPCR assays with identical targets that are relevant to beach water quality assessment. For human-associated assays targeting Bacteroidales HF183 genetic marker, qPCR LODs were 70 times lower and there was no effect of target matrix (artificial freshwater, environmental creek water, and environmental marine water) on PCR or qPCR LODs. The PCR startup and annual costs were the lowest, while the per reaction cost was 62% lower than the Taqman based qPCR and 180% higher than the SYBR based qPCR. For gull-associated assays, there was no significant difference between PCR and qPCR LODs, target matrix did not effect PCR or qPCR LODs, and PCR startup, annual, and per reaction costs were lower. Upgrading to qPCR involves greater startup and annual costs, but this increase may be justified in the case of the human-associated assays with lower detection limits and reduced cost per sample. Copyright © 2014 Elsevier Ltd. All rights reserved.
Riedel, Timothy E.; Zimmer-Faust, Amity G.; Thulsiraj, Vanessa; Madi, Tania; Hanley, Kaitlyn T.; Ebentier, Darcy L.; Byappanahalli, Muruleedhara N.; Layton, Blythe; Raith, Meredith; Boehm, Alexandria B.; Griffith, John F.; Holden, Patricia A.; Shanks, Orin C.; Weisberg, Stephen B.; Jay, Jennifer A.
2014-01-01
Some molecular methods for tracking fecal pollution in environmental waters have both PCR and quantitative PCR (qPCR) assays available for use. To assist managers in deciding whether to implement newer qPCR techniques in routine monitoring programs, we compared detection limits (LODs) and costs of PCR and qPCR assays with identical targets that are relevant to beach water quality assessment. For human-associated assays targeting Bacteroidales HF183 genetic marker, qPCR LODs were 70 times lower and there was no effect of target matrix (artificial freshwater, environmental creek water, and environmental marine water) on PCR or qPCR LODs. The PCR startup and annual costs were the lowest, while the per reaction cost was 62% lower than the Taqman based qPCR and 180% higher than the SYBR based qPCR. For gull-associated assays, there was no significant difference between PCR and qPCR LODs, target matrix did not effect PCR or qPCR LODs, and PCR startup, annual, and per reaction costs were lower. Upgrading to qPCR involves greater startup and annual costs, but this increase may be justified in the case of the human-associated assays with lower detection limits and reduced cost per sample.
Optimizing cost-efficiency in mean exposure assessment - cost functions reconsidered
2011-01-01
Background Reliable exposure data is a vital concern in medical epidemiology and intervention studies. The present study addresses the needs of the medical researcher to spend monetary resources devoted to exposure assessment with an optimal cost-efficiency, i.e. obtain the best possible statistical performance at a specified budget. A few previous studies have suggested mathematical optimization procedures based on very simple cost models; this study extends the methodology to cover even non-linear cost scenarios. Methods Statistical performance, i.e. efficiency, was assessed in terms of the precision of an exposure mean value, as determined in a hierarchical, nested measurement model with three stages. Total costs were assessed using a corresponding three-stage cost model, allowing costs at each stage to vary non-linearly with the number of measurements according to a power function. Using these models, procedures for identifying the optimally cost-efficient allocation of measurements under a constrained budget were developed, and applied on 225 scenarios combining different sizes of unit costs, cost function exponents, and exposure variance components. Results Explicit mathematical rules for identifying optimal allocation could be developed when cost functions were linear, while non-linear cost functions implied that parts of or the entire optimization procedure had to be carried out using numerical methods. For many of the 225 scenarios, the optimal strategy consisted in measuring on only one occasion from each of as many subjects as allowed by the budget. Significant deviations from this principle occurred if costs for recruiting subjects were large compared to costs for setting up measurement occasions, and, at the same time, the between-subjects to within-subject variance ratio was small. In these cases, non-linearities had a profound influence on the optimal allocation and on the eventual size of the exposure data set. Conclusions The analysis procedures developed in the present study can be used for informed design of exposure assessment strategies, provided that data are available on exposure variability and the costs of collecting and processing data. The present shortage of empirical evidence on costs and appropriate cost functions however impedes general conclusions on optimal exposure measurement strategies in different epidemiologic scenarios. PMID:21600023
Optimizing cost-efficiency in mean exposure assessment--cost functions reconsidered.
Mathiassen, Svend Erik; Bolin, Kristian
2011-05-21
Reliable exposure data is a vital concern in medical epidemiology and intervention studies. The present study addresses the needs of the medical researcher to spend monetary resources devoted to exposure assessment with an optimal cost-efficiency, i.e. obtain the best possible statistical performance at a specified budget. A few previous studies have suggested mathematical optimization procedures based on very simple cost models; this study extends the methodology to cover even non-linear cost scenarios. Statistical performance, i.e. efficiency, was assessed in terms of the precision of an exposure mean value, as determined in a hierarchical, nested measurement model with three stages. Total costs were assessed using a corresponding three-stage cost model, allowing costs at each stage to vary non-linearly with the number of measurements according to a power function. Using these models, procedures for identifying the optimally cost-efficient allocation of measurements under a constrained budget were developed, and applied on 225 scenarios combining different sizes of unit costs, cost function exponents, and exposure variance components. Explicit mathematical rules for identifying optimal allocation could be developed when cost functions were linear, while non-linear cost functions implied that parts of or the entire optimization procedure had to be carried out using numerical methods.For many of the 225 scenarios, the optimal strategy consisted in measuring on only one occasion from each of as many subjects as allowed by the budget. Significant deviations from this principle occurred if costs for recruiting subjects were large compared to costs for setting up measurement occasions, and, at the same time, the between-subjects to within-subject variance ratio was small. In these cases, non-linearities had a profound influence on the optimal allocation and on the eventual size of the exposure data set. The analysis procedures developed in the present study can be used for informed design of exposure assessment strategies, provided that data are available on exposure variability and the costs of collecting and processing data. The present shortage of empirical evidence on costs and appropriate cost functions however impedes general conclusions on optimal exposure measurement strategies in different epidemiologic scenarios.
Model-Based Building Detection from Low-Cost Optical Sensors Onboard Unmanned Aerial Vehicles
NASA Astrophysics Data System (ADS)
Karantzalos, K.; Koutsourakis, P.; Kalisperakis, I.; Grammatikopoulos, L.
2015-08-01
The automated and cost-effective building detection in ultra high spatial resolution is of major importance for various engineering and smart city applications. To this end, in this paper, a model-based building detection technique has been developed able to extract and reconstruct buildings from UAV aerial imagery and low-cost imaging sensors. In particular, the developed approach through advanced structure from motion, bundle adjustment and dense image matching computes a DSM and a true orthomosaic from the numerous GoPro images which are characterised by important geometric distortions and fish-eye effect. An unsupervised multi-region, graphcut segmentation and a rule-based classification is responsible for delivering the initial multi-class classification map. The DTM is then calculated based on inpaininting and mathematical morphology process. A data fusion process between the detected building from the DSM/DTM and the classification map feeds a grammar-based building reconstruction and scene building are extracted and reconstructed. Preliminary experimental results appear quite promising with the quantitative evaluation indicating detection rates at object level of 88% regarding the correctness and above 75% regarding the detection completeness.
Roll-to-Roll Gravure Printed Electrochemical Sensors for Wearable and Medical Devices.
Bariya, Mallika; Shahpar, Ziba; Park, Hyejin; Sun, Junfeng; Jung, Younsu; Gao, Wei; Nyein, Hnin Yin Yin; Liaw, Tiffany Sun; Tai, Li-Chia; Ngo, Quynh P; Chao, Minghan; Zhao, Yingbo; Hettick, Mark; Cho, Gyoujin; Javey, Ali
2018-06-25
As recent developments in noninvasive biosensors spearhead the thrust toward personalized health and fitness monitoring, there is a need for high throughput, cost-effective fabrication of flexible sensing components. Toward this goal, we present roll-to-roll (R2R) gravure printed electrodes that are robust under a range of electrochemical sensing applications. We use inks and electrode morphologies designed for electrochemical and mechanical stability, achieving devices with uniform redox kinetics printed on 150 m flexible substrate rolls. We show that these electrodes can be functionalized into consistently high performing sensors for detecting ions, metabolites, heavy metals, and other small molecules in noninvasively accessed biofluids, including sensors for real-time, in situ perspiration monitoring during exercise. This development of robust and versatile R2R gravure printed electrodes represents a key translational step in enabling large-scale, low-cost fabrication of disposable wearable sensors for personalized health monitoring applications.
Shaping perceptions to motivate healthy behavior: the role of message framing.
Rothman, A J; Salovey, P
1997-01-01
Health-relevant communications can be framed in terms of the benefits (gains) or costs (losses) associated with a particular behavior, and the framing of such persuasive messages influences health decision making. Although to ask people to consider a health issue in terms of associated costs is considered an effective way to motivate behavior, empirical findings are inconsistent. In evaluating the effectiveness of framed health messages, investigators must appreciate the context in which health-related decisions are made. The influence of framed information on decision making is contingent on people, first, internalizing the advocated frame and, then, on the degree to which performing a health behavior is perceived as risky. The relative effectiveness of gain-framed or loss-framed appeals depends, in part, on whether a behavior serves an illness-detecting or a health-affirming function. Finally, the authors discuss the cognitive and affective processes that may mediate the influence of framed information on judgment and behavior.
Principles for scaling of distributed direct potable water reuse systems: a modeling study.
Guo, Tianjiao; Englehardt, James D
2015-05-15
Scaling of direct potable water reuse (DPR) systems involves tradeoffs of treatment facility economy-of-scale, versus cost and energy of conveyance including energy for upgradient distribution of treated water, and retention of wastewater thermal energy. In this study, a generalized model of the cost of DPR as a function of treatment plant scale, assuming futuristic, optimized conveyance networks, was constructed for purposes of developing design principles. Fractal landscapes representing flat, hilly, and mountainous topographies were simulated, with urban, suburban, and rural housing distributions placed by modified preferential growth algorithm. Treatment plants were allocated by agglomerative hierarchical clustering, networked to buildings by minimum spanning tree. Simulations assume advanced oxidation-based DPR system design, with 20-year design life and capability to mineralize chemical oxygen demand below normal detection limits, allowing implementation in regions where disposal of concentrate containing hormones and antiscalants is not practical. Results indicate that total DPR capital and O&M costs in rural areas, where systems that return nutrients to the land may be more appropriate, are high. However, costs in urban/suburban areas are competitive with current water/wastewater service costs at scales of ca. one plant per 10,000 residences. This size is relatively small, and costs do not increase significantly until plant service areas fall below 100 to 1000 homes. Based on these results, distributed DPR systems are recommended for consideration for urban/suburban water and wastewater system capacity expansion projects. Copyright © 2015 Elsevier Ltd. All rights reserved.
TERA-MIR radiation: materials, generation, detection and applications III (Conference Presentation)
NASA Astrophysics Data System (ADS)
Pereira, Mauro F.
2016-10-01
This talk summarizes the achievements of COST ACTION MP1204 during the last four years. [M.F. Pereira, Opt Quant Electron 47, 815-820 (2015).]. TERA-MIR main objectives are to advance novel materials, concepts and device designs for generating and detecting THz and Mid Infrared radiation using semiconductor, superconductor, metamaterials and lasers and to beneficially exploit their common aspects within a synergetic approach. We used the unique networking and capacity-building capabilities provided by the COST framework to unify these two spectral domains from their common aspects of sources, detectors, materials and applications. We created a platform to investigate interdisciplinary topics in Physics, Electrical Engineering and Technology, Applied Chemistry, Materials Sciences and Biology and Radio Astronomy. The main emphasis has been on new fundamental material properties, concepts and device designs that are likely to open the way to new products or to the exploitation of new technologies in the fields of sensing, healthcare, biology, and industrial applications. End users are: research centres, academic, well-established and start-up Companies and hospitals. Results are presented along our main lines of research: Intersubband materials and devices with applications to fingerprint spectroscopy; Metamaterials, photonic crystals and new functionalities; Nonlinearities and interaction of radiation with matter including biomaterials; Generation and Detection based on Nitrides and Bismides. The talk is closed by indicating the future direction of the network that will remain active beyond the funding period and our expectations for future joint research.
Interpretation of interference signals in label free integrated interferometric biosensors
NASA Astrophysics Data System (ADS)
Heikkinen, Hanna; Wang, Meng; Okkonen, Matti; Hast, Jukka; Myllylä, Risto
2006-02-01
In the future fast, simple and reliable biosensors will be needed to detect various analytes from different biosamples. This is due to fact that the needs of traditional health care are changing. In the future homecare of patients and peoples' responsibility for their own health will increase. Also, different wellness applications need new parameters to be analysed, reducing costs of traditional health care, which are increasing rapidly. One fascinating and promising sensor type for these applications is an integrated optical interferometric immunosensor, which is manufactured using organic materials. The use of organic materials opens up enormous possibilities to develop different biochemical functions. In label free biosensors the measurement is based on detecting changes in refractive index, which typically are in the range of 10 -6-10 -8 [1]. In this research, theoretically generated interferograms are used to compare various signal processing methods. The goal is to develop an efficient method to analyse the interferogram. Different time domain signal processing methods are studied to determine the measuring resolution and efficiency of these methods. A low cost CCD -element is used in detecting the interferogram dynamics. It was found that in most of the signal processing methods the measuring resolution was mainly limited by pixel size. With calculation of Pearson's correlation coefficient, subpixel resolution was achieved which means that nanometer range optical path differences can be measured. This results in the refractive index resolution of the order of 10 -7.
In vivo optical detection of intranuclear cancer biomarkers using gold nanoparticles
NASA Astrophysics Data System (ADS)
Kumar, Sonia; Sokolov, Konstantin; Richards-Kortum, Rebecca
2006-02-01
Specific genotypes of human papillomavirus (HPV) are well correlated with cervical oncogenesis. The major transforming and immortalizing protein in high risk HPVs, namely HPV16, is E7 protein. E7 protein functions by deregulating the cell cycle and promoting S-phase reentry in differentiated keratinocytes. Currently, clinical diagnosis of cervical cancer is based on phenotypic changes observed in a screening Papanicolaou smear. Although screening has been effective in reducing the occurrence of cervical cancer, the low specificity of the Pap smear results in resources wasted on the evaluation of low-grade lesions not likely to progress to cervical cancer. Molecular characterization of active HPV infections using molecular specific contrast agents are combined with in-vivo optical imaging is proposed to be a cost-effective, non-invasive technique for the detection of cervical pre-cancers. Contrast is achieved by exploiting the peak absorbance and scattering shift in aggregated gold nanoparticles over isolated ones and molecular specificity is achieved via recognition moieties with high affinities for E7. Conjugates of gold nanoparticles and HPV16 anti-E7 antibodies are delivered into the nucleus of living cells and imaged with reflectance confocal microscopy. These contrast agents have been used to successfully enhance contrast in HPV16+ cervical cancer cells over HPV- cells by a factor of 2.5. Further characterization and development of these contrast agents will provide a robust, low cost screening tool for the detection of cervical pre-cancers.
Cook, Sarah E; Marsiske, Michael; McCoy, Karin J M
2009-06-01
Many screening tools for detecting cognitive decline require in-person assessment, which is often not cost-effective or feasible for those with physical limitations. The Modified Telephone Interview for Cognitive Status has been used for screening dementia, but little is known about its usefulness in detecting amnestic mild cognitive impairment. Community-dwelling participants (mean age=74.9, mean education = 16.1 years) were administered the Modified Telephone Interview for Cognitive Status during initial screening and subsequently given a multidomain neuropsychological battery. Participants were classified by consensus panel as cognitively normal older adult (noMCI, N=54) or amnestic mild cognitive impairment (N=17) based on neuropsychological performance and Clinical Dementia Rating Scale interview, but independent of Modified Telephone Interview for Cognitive Status score. There was a significant difference between groups in Modified Telephone Interview for Cognitive Status score (t=8.04, P<.01, noMCI range 32-43, mean [SD]=37.4 [2.5], amnestic mild cognitive impairment range 25-37, mean [SD]=31.2 [3.5]). Discriminant function analysis revealed that TICS-M alone correctly classified 85.9% of participants into their respective diagnostic classification (sensitivity=82.4%, specificity=87.0%). Receiver operating characteristics analysis resulted in cutoff score of 34 that optimized sensitivity and specificity of amnestic mild cognitive impairment classification. The Modified Telephone Interview for Cognitive Status is a brief, cost-effective screening measure for identifying those with and without amnestic mild cognitive impairment.
Zhang, Yuqin; Lin, Fanbo; Zhang, Youyu; Li, Haitao; Zeng, Yue; Tang, Hao; Yao, Shouzhuo
2011-01-01
A new method for the detection of point mutation in DNA based on the monobase-coded cadmium tellurium nanoprobes and the quartz crystal microbalance (QCM) technique was reported. A point mutation (single-base, adenine, thymine, cytosine, and guanine, namely, A, T, C and G, mutation in DNA strand, respectively) DNA QCM sensor was fabricated by immobilizing single-base mutation DNA modified magnetic beads onto the electrode surface with an external magnetic field near the electrode. The DNA-modified magnetic beads were obtained from the biotin-avidin affinity reaction of biotinylated DNA and streptavidin-functionalized core/shell Fe(3)O(4)/Au magnetic nanoparticles, followed by a DNA hybridization reaction. Single-base coded CdTe nanoprobes (A-CdTe, T-CdTe, C-CdTe and G-CdTe, respectively) were used as the detection probes. The mutation site in DNA was distinguished by detecting the decreases of the resonance frequency of the piezoelectric quartz crystal when the coded nanoprobe was added to the test system. This proposed detection strategy for point mutation in DNA is proved to be sensitive, simple, repeatable and low-cost, consequently, it has a great potential for single nucleotide polymorphism (SNP) detection. 2011 © The Japan Society for Analytical Chemistry
A liquid crystal-based sensor for the simple and sensitive detection of cellulase and cysteine.
Wang, Yi; Hu, Qiongzheng; Tian, Tongtong; Gao, Yan'an; Yu, Li
2016-11-01
A liquid crystal (LC)-based sensor, which is capable of monitoring enzymatic activity at the aqueous/LC interface and detecting cellulase and cysteine (Cys), was herein reported. When functionalized with a surfactant, dodecyl β-d-glucopyranoside, the 4-cyano-4'-pentylbiphenyl (5CB) displays a dark-to-bright transition in the optical appearance for cellulase. We attribute this change to the orientational transition of LCs, as a result of enzymatic hydrolysis between cellulase and surfactant. Furthermore, by adding cellulase and Cu(2+), our surfactant-LCs system performs an interesting ability to detect Cys, even though Cys could not interact with surfactant or LC directly. Alternatively, through the strong binding between Cys and Cu(2+), cellulase was able to hydrolyze surfactant in the presence of Cu(2+), leading to the transition of LCs from dark to bright. The detection limit of the LC sensor was around 1×10(-5)mg/mL and 82.5μM for cellulase and Cys, respectively. The LC-based sensor may contribute to the development of low-cost, expedient, and label-free detection for cellulase and Cys and the design strategy may also provide a novel way for detecting multiple analytes. Copyright © 2016 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Litt, Jonathan; Kurtkaya, Mehmet; Duyar, Ahmet
1994-01-01
This paper presents an application of a fault detection and diagnosis scheme for the sensor faults of a helicopter engine. The scheme utilizes a model-based approach with real time identification and hypothesis testing which can provide early detection, isolation, and diagnosis of failures. It is an integral part of a proposed intelligent control system with health monitoring capabilities. The intelligent control system will allow for accommodation of faults, reduce maintenance cost, and increase system availability. The scheme compares the measured outputs of the engine with the expected outputs of an engine whose sensor suite is functioning normally. If the differences between the real and expected outputs exceed threshold values, a fault is detected. The isolation of sensor failures is accomplished through a fault parameter isolation technique where parameters which model the faulty process are calculated on-line with a real-time multivariable parameter estimation algorithm. The fault parameters and their patterns can then be analyzed for diagnostic and accommodation purposes. The scheme is applied to the detection and diagnosis of sensor faults of a T700 turboshaft engine. Sensor failures are induced in a T700 nonlinear performance simulation and data obtained are used with the scheme to detect, isolate, and estimate the magnitude of the faults.
NASA Astrophysics Data System (ADS)
Agarwal, Dilip Kumar; Prasad, Abhinav; Vinchurkar, Madhuri; Gandhi, Sahir; Prabhakar, Deepika; Mukherji, Soumyo; Rao, V. Ramgopal
2018-03-01
Piezoresistive microcantilever-based sensor platform is being used for the last two decades due to their low cost, rapid response and label-free detection system. In this work, we are reporting a microfabricated piezoresistive SU-8/carbon black (polymer cantilever)-based sensor platform for the detection of a clinically important early-stage cardiac marker, i.e., fatty acid-binding protein. It is a most preferred cardiac marker for the diagnosis of acute myocardial infarction. The embodiment of the sensor is a SU-8 microcantilever chip with an integrated nanoparticle composite (carbon black) as a piezoresistor for on-chip electrical transduction. Prior to improving the sensing and susceptibility towards the specific target biomolecule (i.e., h-FABP), the fabricated SU-8 polymer cantilevers were subjected to tailored functionalization. This includes the use of an in-house dry method of hot wire chemical vapour deposition technique to graft amine groups onto the SU-8 surface. The surface-modified microcantilevers were further integrated with a polydimethylsiloxane liquid flow cell and connected externally with an electrical read-out system. Immobilization of the antibody corresponding to the marker protein on the microcantilever surface and subsequent recording of the signal generated upon the antibody-antigen interaction were carried out inside the liquid flow cell. Using our optimized immobilization protocol with this experimental set-up, we were successfully able to detect h-FABP concentration as low as 100 ng/ml.
Rodrigues, Núbia Fernanda Marinho; Neto, Sakae Yotsumoto; Luz, Rita de Cássia Silva; Yamanaka, Hideko
2018-01-01
A renewable, disposable, low cost, and sensitive sensor for the detection of organophosphorus pesticides was constructed by immobilizing the acetylcholinesterase enzyme (AChE), via glutaraldehyde, on magnetic iron nanoparticles (Fe3O4) previously synthesized and functionalized with chitosan (CS). The sensor was denoted AChE/CS/Fe3O4. The magnetic nanoparticles were characterized by Fourier transform infrared spectroscopy and transmission electron microscopy. Acetylthiocholine (ATCh) was incubated with AChE/CS/Fe3O4 and attached to a screen-printed electrode using a magnet. The oxidation of thiocholine (from ATCh hydrolysis) was monitored at an applied potential of +0.5 V vs. Ag/AgCl(KClsat) in 0.1 mol L−1 phosphate buffer solution (pH 7.5) as the supporting electrolyte. A mixture of the pesticide malathion and ATCh was investigated using the same procedure, and the results were compared and expressed as inhibition percentages. For determination of malathion, the proposed sensor presented a linear response in the range from 0.5 to 20 nmol L−1 (R = 0.9942). The limits of detection (LOD) and quantification (LOQ) were 0.3 and 0.8 nmol L−1, respectively. Real samples were also investigated, with recovery values of 96.0% and 108.3% obtained for tomato and pond water samples, respectively. The proposed sensor is a feasible option for malathion detection, offering a linear response, good sensitivity, and a low detection limit. PMID:29438301
NASA Astrophysics Data System (ADS)
Camacho-Navarro, Jhonatan; Ruiz, Magda; Villamizar, Rodolfo; Mujica, Luis; Moreno-Beltrán, Gustavo; Quiroga, Jabid
2017-05-01
Continuous monitoring for damage detection in structural assessment comprises implementation of low cost equipment and efficient algorithms. This work describes the stages involved in the design of a methodology with high feasibility to be used in continuous damage assessment. Specifically, an algorithm based on a data-driven approach by using principal component analysis and pre-processing acquired signals by means of cross-correlation functions, is discussed. A carbon steel pipe section and a laboratory tower were used as test structures in order to demonstrate the feasibility of the methodology to detect abrupt changes in the structural response when damages occur. Two types of damage cases are studied: crack and leak for each structure, respectively. Experimental results show that the methodology is promising in the continuous monitoring of real structures.
GNSS Signal Authentication Via Power and Distortion Monitoring
NASA Astrophysics Data System (ADS)
Wesson, Kyle D.; Gross, Jason N.; Humphreys, Todd E.; Evans, Brian L.
2018-04-01
We propose a simple low-cost technique that enables civil Global Positioning System (GPS) receivers and other civil global navigation satellite system (GNSS) receivers to reliably detect carry-off spoofing and jamming. The technique, which we call the Power-Distortion detector, classifies received signals as interference-free, multipath-afflicted, spoofed, or jammed according to observations of received power and correlation function distortion. It does not depend on external hardware or a network connection and can be readily implemented on many receivers via a firmware update. Crucially, the detector can with high probability distinguish low-power spoofing from ordinary multipath. In testing against over 25 high-quality empirical data sets yielding over 900,000 separate detection tests, the detector correctly alarms on all malicious spoofing or jamming attacks while maintaining a <0.6% single-channel false alarm rate.
NASA Astrophysics Data System (ADS)
Nadal, Laia; Svaluto Moreolo, Michela; Fàbrega, Josep M.; Vílchez, F. Javier
2017-07-01
In this paper, we propose an advanced programmable sliceable-bandwidth variable transceiver (S-BVT) with polarization division multiplexing (PDM) capability as a key enabler to fulfill the requirements for future 5G networks. Thanks to its cost-effective optoelectronic front-end based on orthogonal frequency division multiplexing (OFDM) technology and direct-detection (DD), the proposed S-BVT becomes suitable for next generation highly flexible and scalable metro networks. Polarization beam splitters (PBSs) and controllers (PCs), available on-demand, are included at the transceivers and at the network nodes, further enhancing the system flexibility and promoting an efficient use of the spectrum. 40G-100G PDM transmission has been experimentally demonstrated, within a 4-node photonic mesh network (ADRENALINE testbed), implementing a simplified equalization process.
Quantification of Protein Biomarker Using SERS Nano-Stress Sensing with Peak Intensity Ratiometry
NASA Astrophysics Data System (ADS)
Goh, Douglas; Kong, Kien Voon; Jayakumar, Perumal; Gong, Tianxun; Dinish, U. S.; Olivo, Malini
We report a surface enhanced Raman spectroscopy (SERS) ratiometry method based on peak intensity coupled in a nano-stress sensing platform to detect and quantify biological molecules. Herein, we employed an antibody-conjugated p-aminothiophenol (ATP) functionalized on a bimetallic-film-over-nanosphere (BMFON) substrate as a sensitive SERS platform to detect human haptoglobin (Hp) protein, which is an acute phase protein and a biomarker for various cancers. Correlation between change in the ATP spectral characteristics and concentration of Hp protein was established by examining the peak intensity ratio at 1572cm-1 and 1592cm-1 that reflects the degree of stress experienced by the aromatic ring of ATP during Hp protein-antibody interaction. Development of this platform shows the potential in developing a low-cost and sensitive SERS sensor for the pre-screening of various biomarkers.
Fraga, Rafael de; Stow, Adam J; Magnusson, William E; Lima, Albertina P
2014-01-01
Studies leading to decision-making for environmental licensing often fail to provide accurate estimates of diversity. Measures of snake diversity are regularly obtained to assess development impacts in the rainforests of the Amazon Basin, but this taxonomic group may be subject to poor detection probabilities. Recently, the Brazilian government tried to standardize sampling designs by the implementation of a system (RAPELD) to quantify biological diversity using spatially-standardized sampling units. Consistency in sampling design allows the detection probabilities to be compared among taxa, and sampling effort and associated cost to be evaluated. The cost effectiveness of detecting snakes has received no attention in Amazonia. Here we tested the effects of reducing sampling effort on estimates of species densities and assemblage composition. We identified snakes in seven plot systems, each standardised with 14 plots. The 250 m long centre line of each plot followed an altitudinal contour. Surveys were repeated four times in each plot and detection probabilities were estimated for the 41 species encountered. Reducing the number of observations, or the size of the sampling modules, caused significant loss of information on species densities and local patterns of variation in assemblage composition. We estimated the cost to find a snake as $ 120 U.S., but general linear models indicated the possibility of identifying differences in assemblage composition for half the overall survey costs. Decisions to reduce sampling effort depend on the importance of lost information to target-issues, and may not be the preferred option if there is the potential for identifying individual snake species requiring specific conservation actions. However, in most studies of human disturbance on species assemblages, it is likely to be more cost-effective to focus on other groups of organisms with higher detection probabilities.
de Fraga, Rafael; Stow, Adam J.; Magnusson, William E.; Lima, Albertina P.
2014-01-01
Studies leading to decision-making for environmental licensing often fail to provide accurate estimates of diversity. Measures of snake diversity are regularly obtained to assess development impacts in the rainforests of the Amazon Basin, but this taxonomic group may be subject to poor detection probabilities. Recently, the Brazilian government tried to standardize sampling designs by the implementation of a system (RAPELD) to quantify biological diversity using spatially-standardized sampling units. Consistency in sampling design allows the detection probabilities to be compared among taxa, and sampling effort and associated cost to be evaluated. The cost effectiveness of detecting snakes has received no attention in Amazonia. Here we tested the effects of reducing sampling effort on estimates of species densities and assemblage composition. We identified snakes in seven plot systems, each standardised with 14 plots. The 250 m long centre line of each plot followed an altitudinal contour. Surveys were repeated four times in each plot and detection probabilities were estimated for the 41 species encountered. Reducing the number of observations, or the size of the sampling modules, caused significant loss of information on species densities and local patterns of variation in assemblage composition. We estimated the cost to find a snake as $ 120 U.S., but general linear models indicated the possibility of identifying differences in assemblage composition for half the overall survey costs. Decisions to reduce sampling effort depend on the importance of lost information to target-issues, and may not be the preferred option if there is the potential for identifying individual snake species requiring specific conservation actions. However, in most studies of human disturbance on species assemblages, it is likely to be more cost-effective to focus on other groups of organisms with higher detection probabilities. PMID:25147930
Optimal flight initiation distance.
Cooper, William E; Frederick, William G
2007-01-07
Decisions regarding flight initiation distance have received scant theoretical attention. A graphical model by Ydenberg and Dill (1986. The economics of fleeing from predators. Adv. Stud. Behav. 16, 229-249) that has guided research for the past 20 years specifies when escape begins. In the model, a prey detects a predator, monitors its approach until costs of escape and of remaining are equal, and then flees. The distance between predator and prey when escape is initiated (approach distance = flight initiation distance) occurs where decreasing cost of remaining and increasing cost of fleeing intersect. We argue that prey fleeing as predicted cannot maximize fitness because the best prey can do is break even during an encounter. We develop two optimality models, one applying when all expected future contribution to fitness (residual reproductive value) is lost if the prey dies, the other when any fitness gained (increase in expected RRV) during the encounter is retained after death. Both models predict optimal flight initiation distance from initial expected fitness, benefits obtainable during encounters, costs of escaping, and probability of being killed. Predictions match extensively verified predictions of Ydenberg and Dill's (1986) model. Our main conclusion is that optimality models are preferable to break-even models because they permit fitness maximization, offer many new testable predictions, and allow assessment of prey decisions in many naturally occurring situations through modification of benefit, escape cost, and risk functions.
Hollingshead, Kristy; Kaye, Jeffrey
2017-01-01
Background Alzheimer disease (AD) is a very challenging experience for all those affected. Unfortunately, detection of Alzheimer disease in its early stages when clinical treatments may be most effective is challenging, as the clinical evaluations are time-consuming and costly. Recent studies have demonstrated a close relationship between cognitive function and everyday behavior, an avenue of research that holds great promise for the early detection of cognitive decline. One area of behavior that changes with cognitive decline is language use. Multiple groups have demonstrated a close relationship between cognitive function and vocabulary size, verbal fluency, and semantic ability, using conventional in-person cognitive testing. An alternative to this approach which is inherently ecologically valid may be to take advantage of automated computer monitoring software to continually capture and analyze language use while on the computer. Objective The aim of this study was to understand the relationship between Internet searches as a measure of language and cognitive function in older adults. We hypothesize that individuals with poorer cognitive function will search using fewer unique terms, employ shorter words, and use less obscure words in their searches. Methods Computer monitoring software (WorkTime, Nestersoft Inc) was used to continuously track the terms people entered while conducting searches in Google, Yahoo, Bing, and Ask.com. For all searches, punctuation, accents, and non-ASCII characters were removed, and the resulting search terms were spell-checked before any analysis. Cognitive function was evaluated as a z-normalized summary score capturing five unique cognitive domains. Linear regression was used to determine the relationship between cognitive function and Internet searches by controlling for variables such as age, sex, and education. Results Over a 6-month monitoring period, 42 participants (mean age 81 years [SD 10.5], 83% [35/42] female) conducted 2915 searches using these top search engines. Participants averaged 3.08 words per search (SD 1.6) and 5.77 letters per word (SD 2.2). Individuals with higher cognitive function used more unique terms per search (beta=.39, P=.002) and employed less common terms in their searches (beta=1.39, P=.02). Cognitive function was not significantly associated with the length of the words used in the searches. Conclusions These results suggest that early decline in cognitive function may be detected from the terms people search for when they use the Internet. By continuously tracking basic aspects of Internet search terms, it may be possible to detect cognitive decline earlier than currently possible, thereby enabling proactive treatment and intervention. PMID:28877864
Improving the quantum cost of reversible Boolean functions using reorder algorithm
NASA Astrophysics Data System (ADS)
Ahmed, Taghreed; Younes, Ahmed; Elsayed, Ashraf
2018-05-01
This paper introduces a novel algorithm to synthesize a low-cost reversible circuits for any Boolean function with n inputs represented as a Positive Polarity Reed-Muller expansion. The proposed algorithm applies a predefined rules to reorder the terms in the function to minimize the multi-calculation of common parts of the Boolean function to decrease the quantum cost of the reversible circuit. The paper achieves a decrease in the quantum cost and/or the circuit length, on average, when compared with relevant work in the literature.
Analysis of Different Cost Functions in the Geosect Airspace Partitioning Tool
NASA Technical Reports Server (NTRS)
Wong, Gregory L.
2010-01-01
A new cost function representing air traffic controller workload is implemented in the Geosect airspace partitioning tool. Geosect currently uses a combination of aircraft count and dwell time to select optimal airspace partitions that balance controller workload. This is referred to as the aircraft count/dwell time hybrid cost function. The new cost function is based on Simplified Dynamic Density, a measure of different aspects of air traffic controller workload. Three sectorizations are compared. These are the current sectorization, Geosect's sectorization based on the aircraft count/dwell time hybrid cost function, and Geosect s sectorization based on the Simplified Dynamic Density cost function. Each sectorization is evaluated for maximum and average workload along with workload balance using the Simplified Dynamic Density as the workload measure. In addition, the Airspace Concept Evaluation System, a nationwide air traffic simulator, is used to determine the capacity and delay incurred by each sectorization. The sectorization resulting from the Simplified Dynamic Density cost function had a lower maximum workload measure than the other sectorizations, and the sectorization based on the combination of aircraft count and dwell time did a better job of balancing workload and balancing capacity. However, the current sectorization had the lowest average workload, highest sector capacity, and the least system delay.
Natural frequency identification of smart washer by using adaptive observer
NASA Astrophysics Data System (ADS)
Ito, Hitoshi; Okugawa, Masayuki
2014-04-01
Bolted joints are used in many machines/structures and some of them have been loosened during long time use, and unluckily these bolt loosening may cause a great accident of machines/structures system. These bolted joint, especially in important places, are main object of maintenance inspection. Maintenance inspection with human- involvement is desired to be improved owing to time-consuming, labor-intensive and high-cost. By remote and full automation monitoring of the bolt loosening, constantly monitoring of bolted joint is achieved. In order to detect loosening of bolted joints without human-involvement, applying a structural health monitoring technique and smart structures/materials concept is the key objective. In this study, a new method of bolt loosening detection by adopting a smart washer has been proposed, and the basic detection principle was discussed with numerical analysis about frequency equation of the system, was confirmed experimentally. The smart washer used in this study is in cantilever type with piezoelectric material, which adds the washer the self-sensing and actuation function. The principle used to detect the loosening of the bolts is a method of a bolt loosening detection noted that the natural frequency of a smart washer system is decreasing by the change of the bolt tightening axial tension. The feature of this proposed method is achieving to identify the natural frequency at current condition on demand by adopting the self-sensing and actuation function and system identification algorithm for varying the natural frequency depending the bolt tightening axial tension. A novel bolt loosening detection method by adopting adaptive observer is proposed in this paper. The numerical simulations are performed to verify the possibility of the adaptive observer-based loosening detection. Improvement of the detection accuracy for a bolt loosening is confirmed by adopting initial parameter and variable adaptive gain by numerical simulation.
NASA Astrophysics Data System (ADS)
Palestini, C.; Basso, A.; Graziani, L.
2018-05-01
The contribution, considering the use of low-cost photogrammetric detection methodologies and the use of asset Historical-BIM, has as its aim the theme of knowledge and the adaptation of safety in school buildings, a topic brought to attention by the many situations of seismic risk that have interested the central Apennines in Italy. The specific investigation is referred to the Abruzzo region, hit by the recent earthquakes of 2016 and 2009 that have highlighted the vulnerability of the building structures involved in a large seismic crater covering large areas of the territory. The need to consider in advance the performance standards of building components, especially concerning the strategic ways of the functions contained in them, starts here. In this sense, the school buildings have emerged among the types on which to pay attention, a study theme to be promptly considered, considering the functions performed within them and the possible criticality of such constructions, often dated, enlarged or readjusted without appropriate seismic adaptation plans. From here derives the purpose of the research that is directed towards a systematic recognition of the scholastic heritage, deriving from objective and rapid surveys at low cost, taking into consideration the as-built and the different formal and structural aspects that define the architectural organisms to analyse and manage through three-dimensional models that can be interrogated using HBIM connected to databases containing information of a structural and functional nature. In summary, through the implementation of information in the BIM model, it will be possible to query and obtain in real time all the necessary information to optimize, in terms of efficiency, costs, and future maintenance operations.
Edelsberg, John; Weycker, Derek; Atwood, Mark; Hamilton-Fairley, Geoffrey; Jett, James R
2018-01-01
Patients who have incidentally detected pulmonary nodules and an estimated intermediate risk (5-60%) of lung cancer frequently are followed via computed tomography (CT) surveillance to detect nodule growth, despite guidelines for a more aggressive diagnostic strategy. We examined the cost-effectiveness of an autoantibody test (AABT)-Early Cancer Detection Test-Lung (EarlyCDT-LungTM)-as an aid to early diagnosis of lung cancer among such patients. We developed a decision-analytic model to evaluate use of the AABT versus CT surveillance alone. In the model, patients with a positive AABT-because they are at substantially enhanced risk of lung cancer-are assumed to go directly to biopsy, resulting in diagnosis of lung cancer in earlier stages than under current guidelines (a beneficial stage shift). Patients with a negative AABT, and those scheduled for CT surveillance alone, are assumed to have periodic CT screenings to detect rapid growth and thus to have their lung cancers diagnosed-on average-at more advanced stages. Among 1,000 patients who have incidentally detected nodules 8-30 mm, have an intermediate-risk of lung cancer, and are evaluated by CT surveillance alone, 95 (9.5%) are assumed to have lung cancer (local, 73.6%; regional, 22.0%; distant, 4.4%). With use of the AABT set at a sensitivity/specificity of 41%/93% (stage shift = 10.8%), although expected costs would be higher by $949,442 ($949 per person), life years would be higher by 53 (0.05 per person), resulting in a cost per life-year gained of $18,029 and a cost per quality-adjusted life year (QALY) gained of $24,330. With use of the AABT set at a sensitivity/specificity of 28%/98% (stage shift = 7.4%), corresponding cost-effectiveness ratios would be $18,454 and $24,833. Under our base-case assumptions, and reasonable variations thereof, using AABT as an aid in the early diagnosis of lung cancer in patients with incidentally detected pulmonary nodules who are estimated to be at intermediate risk of lung cancer and are scheduled for CT surveillance alone is likely to be a cost-effective use of healthcare resources.
NASA Astrophysics Data System (ADS)
O'Shaughnessy, Richard; Blackman, Jonathan; Field, Scott E.
2017-07-01
The recent direct observation of gravitational waves has further emphasized the desire for fast, low-cost, and accurate methods to infer the parameters of gravitational wave sources. Due to expense in waveform generation and data handling, the cost of evaluating the likelihood function limits the computational performance of these calculations. Building on recently developed surrogate models and a novel parameter estimation pipeline, we show how to quickly generate the likelihood function as an analytic, closed-form expression. Using a straightforward variant of a production-scale parameter estimation code, we demonstrate our method using surrogate models of effective-one-body and numerical relativity waveforms. Our study is the first time these models have been used for parameter estimation and one of the first ever parameter estimation calculations with multi-modal numerical relativity waveforms, which include all \\ell ≤slant 4 modes. Our grid-free method enables rapid parameter estimation for any waveform with a suitable reduced-order model. The methods described in this paper may also find use in other data analysis studies, such as vetting coincident events or the computation of the coalescing-compact-binary detection statistic.
van Grinsven, Bart; Eersels, Kasper; Peeters, Marloes; Losada-Pérez, Patricia; Vandenryt, Thijs; Cleij, Thomas J; Wagner, Patrick
2014-08-27
In recent years, biosensors have become increasingly important in various scientific domains including medicine, biology, and pharmacology, resulting in an increased demand for fast and effective readout techniques. In this Spotlight on Applications, we report on the recently developed heat-transfer method (HTM) and illustrate the use of the technique by zooming in on four established bio(mimetic) sensor applications: (i) mutation analysis in DNA sequences, (ii) cancer cell identification through surface-imprinted polymers, (iii) detection of neurotransmitters with molecularly imprinted polymers, and (iv) phase-transition analysis in lipid vesicle layers. The methodology is based on changes in heat-transfer resistance at a functionalized solid-liquid interface. To this extent, the device applies a temperature gradient over this interface and monitors the temperature underneath and above the functionalized chip in time. The heat-transfer resistance can be obtained by dividing this temperature gradient by the power needed to achieve a programmed temperature. The low-cost, fast, label-free and user-friendly nature of the technology in combination with a high degree of specificity, selectivity, and sensitivity makes HTM a promising sensor technology.
Graph-based surface reconstruction from stereo pairs using image segmentation
NASA Astrophysics Data System (ADS)
Bleyer, Michael; Gelautz, Margrit
2005-01-01
This paper describes a novel stereo matching algorithm for epipolar rectified images. The method applies colour segmentation on the reference image. The use of segmentation makes the algorithm capable of handling large untextured regions, estimating precise depth boundaries and propagating disparity information to occluded regions, which are challenging tasks for conventional stereo methods. We model disparity inside a segment by a planar equation. Initial disparity segments are clustered to form a set of disparity layers, which are planar surfaces that are likely to occur in the scene. Assignments of segments to disparity layers are then derived by minimization of a global cost function via a robust optimization technique that employs graph cuts. The cost function is defined on the pixel level, as well as on the segment level. While the pixel level measures the data similarity based on the current disparity map and detects occlusions symmetrically in both views, the segment level propagates the segmentation information and incorporates a smoothness term. New planar models are then generated based on the disparity layers' spatial extents. Results obtained for benchmark and self-recorded image pairs indicate that the proposed method is able to compete with the best-performing state-of-the-art algorithms.
Detection of Fiber Layer-Up Lamination Order of CFRP Composite Using Thermal-Wave Radar Imaging
NASA Astrophysics Data System (ADS)
Wang, Fei; Liu, Junyan; Liu, Yang; Wang, Yang; Gong, Jinlong
2016-09-01
In this paper, thermal-wave radar imaging (TWRI) is used as a nondestructive inspection method to evaluate carbon-fiber-reinforced-polymer (CFRP) composite. An inverse methodology that combines TWRI with numerical optimization technique is proposed to determine the fiber layer-up lamination sequences of anisotropic CFRP composite. A 7-layer CFRP laminate [0°/45°/90°/0°]_{{s}} is heated by a chirp-modulated Gaussian laser beam, and then finite element method (FEM) is employed to calculate the temperature field of CFRP laminates. The phase based on lock-in correlation between reference chirp signal and the thermal-wave signal is performed to obtain the phase image of TWRI, and the least square method is applied to reconstruct the cost function that minimizes the square of the difference between the phase of TWRI inspection and numerical calculation. A hybrid algorithm that combines the simulation annealing with Nelder-Mead simplex research method is employed to solve the reconstructed cost function and find the global optimal solution of the layer-up sequences of CFRP composite. The result shows the feasibility of estimating the fiber layer-up lamination sequences of CFRP composite with optimal discrete and constraint conditions.
Hybrid architecture for building secure sensor networks
NASA Astrophysics Data System (ADS)
Owens, Ken R., Jr.; Watkins, Steve E.
2012-04-01
Sensor networks have various communication and security architectural concerns. Three approaches are defined to address these concerns for sensor networks. The first area is the utilization of new computing architectures that leverage embedded virtualization software on the sensor. Deploying a small, embedded virtualization operating system on the sensor nodes that is designed to communicate to low-cost cloud computing infrastructure in the network is the foundation to delivering low-cost, secure sensor networks. The second area focuses on securing the sensor. Sensor security components include developing an identification scheme, and leveraging authentication algorithms and protocols that address security assurance within the physical, communication network, and application layers. This function will primarily be accomplished through encrypting the communication channel and integrating sensor network firewall and intrusion detection/prevention components to the sensor network architecture. Hence, sensor networks will be able to maintain high levels of security. The third area addresses the real-time and high priority nature of the data that sensor networks collect. This function requires that a quality-of-service (QoS) definition and algorithm be developed for delivering the right data at the right time. A hybrid architecture is proposed that combines software and hardware features to handle network traffic with diverse QoS requirements.