Two in one: making electron and ion measurements using a single MCP in future top hat instruments.
NASA Astrophysics Data System (ADS)
Bedington, Robert; Saito, Yoshifumi
To allow for the reduced use of spacecraft resources in future missions, we are developing techniques to enable both electrons and ions to be measured in a single top hat instrument. Top hat energy analyser instruments typically analyse charged particles from a few eV to a few tens keV. They consist of an electrostatic, energy-analyser section and a detector. MCPs (micro-channel plates) are the most commonly used detectors, because of their high sensitivity and strong heritage in space instrumentation. To detect the lowest energies of charged particles, a pre-accelerating bias potential is applied to the front surface of the MCP, however this voltage cannot be altered quickly without drastically affecting the detector response. Any instrument that detects both electrons and ions, will therefore typically use two detectors (with fixed voltages)—one for electrons, one for ions, and will often use two separate energy analysers. Significant resource savings are available however if just a single MCP can be used. This can be achieved by having incoming ions (and optionally incoming electrons also) impact a secondary electron emitting material, and thus release secondary electrons to be detected by a positively biased (electron-detecting) MCP. Unlike MCPs, the electrostatic, energy-analyser sections are able to have their voltages cycled extremely rapidly, so that they can be made to sample electrons and then ions in quick succession with minimal design changes required. Two secondary electron conversion methods are being investigated: ultra-thin carbon foils, and dynodes. Using carbon foils in front of the MCPs, incoming ions can be detected by the secondary electrons they release, while incoming electrons pass straight through them. Using dynodes all incoming particles can be converted to secondary electrons before detection. The challenges include finding materials with uniform electron emission responses for the desired energies and particles, managing electric fields and scattered primary electrons. Experiments pertaining to this research will be discussed. These investigations are being pursued as prototype developments for the SCOPE mission for use on the EISA (Electron & Ion Spectrum Analyzer) instrument.
Towards linking patients and clinical information: detecting UMLS concepts in e-mail.
Brennan, Patricia Flatley; Aronson, Alan R
2003-01-01
The purpose of this project is to explore the feasibility of detecting terms within the electronic messages of patients that could be used to effectively search electronic knowledge resources and bring health information resources into the hands of patients. Our team is exploring the application of the natural language processing (NLP) tools built within the Lister Hill Center at the National Library of Medicine (NLM) to the challenge of detecting relevant concepts from the Unified Medical Language System (UMLS) within the free text of lay people's electronic messages (e-mail). We obtained a sample of electronic messages sent by patients participating in a randomized field evaluation of an internet-based home care support service to the project nurse, and we subjected elements of these messages to a series of analyses using several vocabularies from the UMLS Metathesaurus and the selected NLP tools. The nursing vocabularies provide an excellent starting point for this exercise because their domain encompasses patient's responses to health challenges. In successive runs we augmented six nursing vocabularies (NANDA Nursing Diagnosis, Nursing Interventions Classification, Nursing Outcomes Classification, Home Health Classification, Omaha System, and the Patient Care Data Set) with selected sets of clinical terminologies (International Classification of Primary Care; International Classification of Primary Care- American English; Micromedex DRUGDEX; National Drug Data File; Thesaurus of Psychological Terms; WHO Adverse Drug Reaction Terminology) and then additionally with either Medical Subject Heading (MeSH) or SNOMED International terms. The best performance was obtained when the nursing vocabularies were complemented with selected clinical terminologies. These findings have implications not only for facilitating lay people's access to electronic knowledge resources but may also be of assistance in developing new tools to aid in linking free text (e.g., clinical notes) to lexically complex knowledge resources such as those emerging from the Human Genome Project.
Holographic particle detection
NASA Technical Reports Server (NTRS)
Bowen, Theodore
1988-01-01
The feasibility was studied of developing a novel particle track detector based on the detection of 1p-1s emission radiation from electron bubbles in liquid helium. The principles, design, construction, and initial testing of the detection system have been described in previous reports. The main obstacle encountered was the construction of the liquid-helium tight infrared windows. Despite numerous efforts in testing and redesigning the windows, the problem of window leakage at low temperature persisted. Due to limited time and resources, attention was switched to investigating the possibility of using room-temperature liquid as the detection medium. A possible mechanism was the detection of de-excitation radiation emitted from localized electrons in common liquids where electrons exhibit low mobilities, as suggested in the previous report. The purity of the liquid is critical in this method as the dissolved impurities (such as oxygen), even in trace amounts, will act as scavengers of electrons. Another mechanism is discussed whereby the formation of the superoxide ions by electron scavenging behavior of dissolved oxygen is exploited to detect the track of ionizing particles. An experiment to measure the ionization current produced in a liquid by a pulsed X-ray beam in order to study propertiies of the ions is also reported.
Rattanaumpawan, Pinyo; Boonyasiri, Adhiratha; Vong, Sirenda; Thamlikitkul, Visanu
2018-02-01
Electronic surveillance of infectious diseases involves rapidly collecting, collating, and analyzing vast amounts of data from interrelated multiple databases. Although many developed countries have invested in electronic surveillance for infectious diseases, the system still presents a challenge for resource-limited health care settings. We conducted a systematic review by performing a comprehensive literature search on MEDLINE (January 2000-December 2015) to identify studies relevant to electronic surveillance of infectious diseases. Study characteristics and results were extracted and systematically reviewed by 3 infectious disease physicians. A total of 110 studies were included. Most surveillance systems were developed and implemented in high-income countries; less than one-quarter were conducted in low-or middle-income countries. Information technologies can be used to facilitate the process of obtaining laboratory, clinical, and pharmacologic data for the surveillance of infectious diseases, including antimicrobial resistance (AMR) infections. These novel systems require greater resources; however, we found that using electronic surveillance systems could result in shorter times to detect targeted infectious diseases and improvement of data collection. This study highlights a lack of resources in areas where an effective, rapid surveillance system is most needed. The availability of information technology for the electronic surveillance of infectious diseases, including AMR infections, will facilitate the prevention and containment of such emerging infectious diseases. Copyright © 2018 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
ISS-An Electronic Syndromic Surveillance System for Infectious Disease in Rural China
Yan, Weirong; Palm, Lars; Lu, Xin; Nie, Shaofa; Xu, Biao; Zhao, Qi; Tao, Tao; Cheng, Liwei; Tan, Li; Dong, Hengjin; Diwan, Vinod K.
2013-01-01
Background syndromic surveillance system has great advantages in promoting the early detection of epidemics and reducing the necessities of disease confirmation, and it is especially effective for surveillance in resource poor settings. However, most current syndromic surveillance systems are established in developed countries, and there are very few reports on the development of an electronic syndromic surveillance system in resource-constrained settings. Objective this study describes the design and pilot implementation of an electronic surveillance system (ISS) for the early detection of infectious disease epidemics in rural China, complementing the conventional case report surveillance system. Methods ISS was developed based on an existing platform ‘Crisis Information Sharing Platform’ (CRISP), combining with modern communication and GIS technology. ISS has four interconnected functions: 1) work group and communication group; 2) data source and collection; 3) data visualization; and 4) outbreak detection and alerting. Results As of Jan. 31st 2012, ISS has been installed and pilot tested for six months in four counties in rural China. 95 health facilities, 14 pharmacies and 24 primary schools participated in the pilot study, entering respectively 74256, 79701, and 2330 daily records into the central database. More than 90% of surveillance units at the study sites are able to send daily information into the system. In the paper, we also presented the pilot data from health facilities in the two counties, which showed the ISS system had the potential to identify the change of disease patterns at the community level. Conclusions The ISS platform may facilitate the early detection of infectious disease epidemic as it provides near real-time syndromic data collection, interactive visualization, and automated aberration detection. However, several constraints and challenges were encountered during the pilot implementation of ISS in rural China. PMID:23626853
ISS--an electronic syndromic surveillance system for infectious disease in rural China.
Yan, Weirong; Palm, Lars; Lu, Xin; Nie, Shaofa; Xu, Biao; Zhao, Qi; Tao, Tao; Cheng, Liwei; Tan, Li; Dong, Hengjin; Diwan, Vinod K
2013-01-01
Syndromic surveillance system has great advantages in promoting the early detection of epidemics and reducing the necessities of disease confirmation, and it is especially effective for surveillance in resource poor settings. However, most current syndromic surveillance systems are established in developed countries, and there are very few reports on the development of an electronic syndromic surveillance system in resource-constrained settings. This study describes the design and pilot implementation of an electronic surveillance system (ISS) for the early detection of infectious disease epidemics in rural China, complementing the conventional case report surveillance system. ISS was developed based on an existing platform 'Crisis Information Sharing Platform' (CRISP), combining with modern communication and GIS technology. ISS has four interconnected functions: 1) work group and communication group; 2) data source and collection; 3) data visualization; and 4) outbreak detection and alerting. As of Jan. 31(st) 2012, ISS has been installed and pilot tested for six months in four counties in rural China. 95 health facilities, 14 pharmacies and 24 primary schools participated in the pilot study, entering respectively 74,256, 79,701, and 2330 daily records into the central database. More than 90% of surveillance units at the study sites are able to send daily information into the system. In the paper, we also presented the pilot data from health facilities in the two counties, which showed the ISS system had the potential to identify the change of disease patterns at the community level. The ISS platform may facilitate the early detection of infectious disease epidemic as it provides near real-time syndromic data collection, interactive visualization, and automated aberration detection. However, several constraints and challenges were encountered during the pilot implementation of ISS in rural China.
Muto, Shunsuke; Tatsumi, Kazuyoshi
2017-02-08
Advancements in the field of renewable energy resources have led to a growing demand for the analysis of light elements at the nanometer scale. Detection of lithium is one of the key issues to be resolved for providing guiding principles for the synthesis of cathode active materials, and degradation analysis after repeated use of those materials. We have reviewed the different techniques currently used for the characterization of light elements such as high-resolution transmission electron microscopy, scanning transmission electron microscopy (STEM) and electron energy-loss spectroscopy (EELS). In the present study, we have introduced a methodology to detect lithium in solid materials, particularly for cathode active materials used in lithium-ion battery. The chemical states of lithium were isolated and analyzed from the overlapping multiple spectral profiles, using a suite of STEM, EELS and hyperspectral image analysis. The method was successfully applied in the chemical state analyses of hetero-phases near the surface and grain boundary regions of the active material particles formed by chemical reactions between the electrolyte and the active materials. © The Author 2016. Published by Oxford University Press on behalf of The Japanese Society of Microscopy. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Liu, Ruxiu; Wang, Ningquan; Kamili, Farhan; Sarioglu, A Fatih
2016-04-21
Numerous biophysical and biochemical assays rely on spatial manipulation of particles/cells as they are processed on lab-on-a-chip devices. Analysis of spatially distributed particles on these devices typically requires microscopy negating the cost and size advantages of microfluidic assays. In this paper, we introduce a scalable electronic sensor technology, called microfluidic CODES, that utilizes resistive pulse sensing to orthogonally detect particles in multiple microfluidic channels from a single electrical output. Combining the techniques from telecommunications and microfluidics, we route three coplanar electrodes on a glass substrate to create multiple Coulter counters producing distinct orthogonal digital codes when they detect particles. We specifically design a digital code set using the mathematical principles of Code Division Multiple Access (CDMA) telecommunication networks and can decode signals from different microfluidic channels with >90% accuracy through computation even if these signals overlap. As a proof of principle, we use this technology to detect human ovarian cancer cells in four different microfluidic channels fabricated using soft lithography. Microfluidic CODES offers a simple, all-electronic interface that is well suited to create integrated, low-cost lab-on-a-chip devices for cell- or particle-based assays in resource-limited settings.
Development of a HIV-1 Virus Detection System Based on Nanotechnology.
Lee, Jin-Ho; Oh, Byung-Keun; Choi, Jeong-Woo
2015-04-27
Development of a sensitive and selective detection system for pathogenic viral agents is essential for medical healthcare from diagnostics to therapeutics. However, conventional detection systems are time consuming, resource-intensive and tedious to perform. Hence, the demand for sensitive and selective detection system for virus are highly increasing. To attain this aim, different aspects and techniques have been applied to develop virus sensor with improved sensitivity and selectivity. Here, among those aspects and techniques, this article reviews HIV virus particle detection systems incorporated with nanotechnology to enhance the sensitivity. This review mainly focused on four different detection system including vertically configured electrical detection based on scanning tunneling microscopy (STM), electrochemical detection based on direct electron transfer in virus, optical detection system based on localized surface plasmon resonance (LSPR) and surface enhanced Raman spectroscopy (SERS) using plasmonic nanoparticle.
Production and Detection of Spin-Entangled Electrons in Mesoscopic Conductors
NASA Astrophysics Data System (ADS)
Burkard, Guido
2006-03-01
Electron spins are an extremely versatile form of quantum bits. When localized in quantum dots, they can form a register for quantum computation. Moreover, being attached to a charge in a mesoscopic conductor allows the electron spin to play the role of a mobile carrier of quantum information similarly to photons in optical quantum communication. Since entanglement is a basic resource in quantum communication, the production and detection of spin-entangled Einstein-Podolsky-Rosen (EPR) pairs of electrons are of great interest. Besides the practical importance, it is of fundamental interest to test quantum non-locality for electrons. I review the theoretical schemes for the entanglement production in superconductor-normal junctions [1] and other systems. The electron spin entanglement can be detected and quantified from measurements of the fluctuations (shot noise) of the charge current after the electrons have passed through an electronic beam splitter [2,3]. This two-particle interference effect is related to the Hanbury-Brown and Twiss experiment and leads to a doubling of the shot noise SI=<δI δI>φ=0 for spin-entangled states, allowing their differentiation from unentangled pairs. I report on the role of spin-orbit coupling (Rashba and Dresselhaus) in a complete characterization of the spin entanglement [4]. Finally, I address the effects of a discrete level spectrum in the mesoscopic leads and of backscattering and decoherence.[1] P. Recher, E. V. Sukhorukov, D. Loss, Phys. Rev. B 63, 165314 (2001)[2] G. Burkard, D. Loss, E. V. Sukhorukov, Phys. Rev. B 61, R16303 (2000)[3] G. Burkard and D. Loss, Phys. Rev. Lett.91, 087903 (2003)[4] J. C. Egues, G. Burkard, D. Saraga, J. Schliemann, D. Loss, cond-mat/0509038, to appear in Phys.Rev.B (2005).
ERIC Educational Resources Information Center
Bhukuvhani, Crispen; Chiparausha, Blessing; Zuvalinyenga, Dorcas
2012-01-01
Lecturers use various electronic resources at different frequencies. The university library's information literacy skills workshops and seminars are the main sources of knowledge of accessing electronic resources. The use of electronic resources can be said to have positively affected lecturers' pedagogical practices and their work in general. The…
From Tedious to Timely: Screencasting to Troubleshoot Electronic Resource Issues
ERIC Educational Resources Information Center
Hartnett, Eric; Thompson, Carole
2010-01-01
The shift from traditional print materials to electronic resources, in conjunction with the rise in the number of distance education programs, has left many electronic resource librarians scrambling to keep up with the resulting inundation of electronic resource problems. When it comes to diagnosing these problems, words do not always convey all…
Electronic Resources and Mission Creep: Reorganizing the Library for the Twenty-First Century
ERIC Educational Resources Information Center
Stachokas, George
2009-01-01
The position of electronic resources librarian was created to serve as a specialist in the negotiation of license agreements for electronic resources, but mission creep has added more functions to the routine work of electronic resources such as cataloging, gathering information for collection development, and technical support. As electronic…
ERIC Educational Resources Information Center
England, Lenore; Fu, Li
2011-01-01
A critical part of electronic resources management, the electronic resources evaluation process is multi-faceted and includes a seemingly endless range of resources and tools involving numerous library staff. A solution is to build a Web site to bring all of the components together that can be implemented quickly and result in an organizational…
2012-01-01
Background Emerging public health threats often originate in resource-limited countries. In recognition of this fact, the World Health Organization issued revised International Health Regulations in 2005, which call for significantly increased reporting and response capabilities for all signatory nations. Electronic biosurveillance systems can improve the timeliness of public health data collection, aid in the early detection of and response to disease outbreaks, and enhance situational awareness. Methods As components of its Suite for Automated Global bioSurveillance (SAGES) program, The Johns Hopkins University Applied Physics Laboratory developed two open-source, electronic biosurveillance systems for use in resource-limited settings. OpenESSENCE provides web-based data entry, analysis, and reporting. ESSENCE Desktop Edition provides similar capabilities for settings without internet access. Both systems may be configured to collect data using locally available cell phone technologies. Results ESSENCE Desktop Edition has been deployed for two years in the Republic of the Philippines. Local health clinics have rapidly adopted the new technology to provide daily reporting, thus eliminating the two-to-three week data lag of the previous paper-based system. Conclusions OpenESSENCE and ESSENCE Desktop Edition are two open-source software products with the capability of significantly improving disease surveillance in a wide range of resource-limited settings. These products, and other emerging surveillance technologies, can assist resource-limited countries compliance with the revised International Health Regulations. PMID:22950686
Use of Electronic Resources for Psychiatry Clerkship Learning: A Medical Student Survey.
Snow, Caitlin E; Torous, John; Gordon-Elliott, Janna S; Penzner, Julie B; Meyer, Fermonta; Boland, Robert
2017-10-01
The primary aim of this study is to examine medical students' use patterns, preferences, and perceptions of electronic educational resources available for psychiatry clerkship learning. Eligible participants included medical students who had completed the psychiatry clerkship during a 24-month period. An internet-based questionnaire was used to collect information regarding the outcomes described above. A total of 68 medical students responded to the survey. Most respondents reported high utilization of electronic resources on an array of devices for psychiatry clerkship learning and indicated a preference for electronic over print resources. The most commonly endorsed barriers to the use of electronic resources were that the source contained irrelevant and non-specific content, access was associated with a financial cost, and faculty guidance on recommended resources was insufficient. Respondents indicated a wish for more psychiatry-specific electronic learning resources. The authors' results suggest that a demand exists for high-quality electronic and portable learning tools that are relevant to medical student education in psychiatry. Psychiatry educators are usefully positioned to be involved in the development of such resources.
Kohler, Steven W; Chen, Richard; Kagan, Alex; Helvey, Dustin W; Buccigrossi, David
2013-06-01
In order to determine the effects of implementation of an electronic medical record on rates of repeat computed tomography (CT) scanning in the emergency department (ED) setting, we analyzed the utilization of CT of the kidneys, ureters, and bladder (CT KUB) for the detection of urinary tract calculi for periods before and after the implementation of a hospital-wide electronic medical record system. Rates of repeat CT scanning within a 6-month period of previous scan were determined pre- and post-implementation and compared. Prior to implementation, there was a 6-month repeat rate of 6.2 % compared with the post-implementation period, which was associated with a 6-month repeat rate of 4.1 %. Statistical analysis using a two-sample, one-tailed t test for difference of means was associated with a p value of 0.00007. This indicates that the implementation of the electronic medical record system was associated with a 34 % decrease in 6-month repeat CT KUB scans. We conclude that the use of an electronic medical record can be associated with a decrease in utilization of unnecessary repeat CT imaging, leading to decreased cumulative lifetime risk for cancer in these patients and more efficient utilization of ED and radiologic resources.
Assessing Ongoing Electronic Resource Purchases: Linking Tools to Synchronize Staff Workflows
ERIC Educational Resources Information Center
Carroll, Jeffrey D.; Major, Colleen; O'Neal, Nada; Tofanelli, John
2012-01-01
Ongoing electronic resource purchases represent a substantial proportion of collections budgets. Recognizing the necessity of systematic ongoing assessment with full selector engagement, Columbia University Libraries appointed an Electronic Resources Assessment Working Group to promote the inclusion of such resources within our current culture of…
Strain Coupling of a Nitrogen-Vacancy Center Spin to a Diamond Mechanical Oscillator
NASA Astrophysics Data System (ADS)
Teissier, J.; Barfuss, A.; Appel, P.; Neu, E.; Maletinsky, P.
2014-07-01
We report on single electronic spins coupled to the motion of mechanical resonators by a novel mechanism based on crystal strain. Our device consists of single-crystal diamond cantilevers with embedded nitrogen-vacancy center spins. Using optically detected electron spin resonance, we determine the unknown spin-strain coupling constants and demonstrate that our system resides well within the resolved sideband regime. We realize coupling strengths exceeding 10 MHz under mechanical driving and show that our system has the potential to reach strong coupling. Our novel hybrid system forms a resource for future experiments on spin-based cantilever cooling and coherent spin-oscillator coupling.
Electronic Resource Management and Design
ERIC Educational Resources Information Center
Abrams, Kimberly R.
2015-01-01
We have now reached a tipping point at which electronic resources comprise more than half of academic library budgets. Because of the increasing work associated with the ever-increasing number of e-resources, there is a trend to distribute work throughout the library even in the presence of an electronic resources department. In 2013, the author…
NASA Technical Reports Server (NTRS)
1998-01-01
Table of Contents: Federal Cleanup Programs; Federal Site Remediation Technology Development Assistance Programs; Federal Site Remediation Technology Development Electronic Data Bases; Federal Electronic Resources for Site Remediation Technology Information; Other Electronic Resources for Site Remediation Technology Information; Other Electronic Resources for Site Remediation Technology Information; Selected Bibliography: Federal Publication on Alternative and Innovative Site Remediation; and Appendix: Technology Program Contacts.
Lachance, Philippe; Villeneuve, Pierre-Marc; Wilson, Francis P; Selby, Nicholas M; Featherstone, Robin; Rewa, Oleksa; Bagshaw, Sean M
2016-05-05
Acute kidney injury (AKI) is a common complication in hospitalised patients. It imposes significant risk for major morbidity and mortality. Moreover, patients suffering an episode of AKI consume considerable health resources. Recently, a number of studies have evaluated the implementation of automated electronic alerts (e-alerts) configured from electronic medical records (EMR) and clinical information systems (CIS) to warn healthcare providers of early or impending AKI in hospitalised patients. The impact of e-alerts on care processes, patient outcomes and health resource use, however, remains uncertain. We will perform a systematic review to describe and appraise e-alerts for AKI, and evaluate their impact on processes of care, clinical outcomes and health services use. In consultation with a research librarian, a search strategy will be developed and electronic databases (ie, MEDLINE, EMBASE, CINAHL, Cochrane Library and Inspec via Engineering Village) searched. Selected grey literature sources will also be searched. Search themes will focus on e-alerts and AKI. Citation screening, selection, quality assessment and data abstraction will be performed in duplicate. The primary analysis will be narrative; however, where feasible, pooled analysis will be performed. Each e-alert will be described according to trigger, type of alert, target recipient and degree of intrusiveness. Pooled effect estimates will be described, where applicable. Our systematic review will synthesise the literature on the value of e-alerts to detect AKI, and their impact on processes, patient-centred outcomes and resource use, and also identify key knowledge gaps and barriers to implementation. This is a fundamental step in a broader research programme aimed to understand the ideal structure of e-alerts, target population and methods for implementation, to derive benefit. Research ethics approval is not required for this review. CRD42016033033. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Do GPs use electronic mental health resources? - a qualitative study.
Austin, David; Pier, Ciaran; Mitchell, Joanna; Schattner, Peter; Wade, Victoria; Pierce, David; Klein, Britt
2006-05-01
The Better Outcomes in Mental Health Care (BOMHC) initiative encourages general practitioners to use electronic mental health resources (EMHRs) during consultation with patients requiring psychological assistance. However, there is little data on GPs' acceptance and use of EMHRs. Semistructured interviews were conducted with 27 GPs to determine their attitude toward EMHRs, and their use during consultation with patients. Few GPs reported frequently using EMHRs in consultation. Identified barriers to use included lack of familiarity with information technology, and insufficient knowledge of available resources. Identified advantages of electronic resources included high patient acceptance, time efficiency, and improved quality of information. General practitioners recognise several advantages of utilising electronic resources for managing patients with mental illness. However, GPs are not sufficiently familiar with electronic resources to use them effectively. This could be overcome by education.
Making sense of the electronic resource marketplace: trends in health-related electronic resources.
Blansit, B D; Connor, E
1999-01-01
Changes in the practice of medicine and technological developments offer librarians unprecedented opportunities to select and organize electronic resources, use the Web to deliver content throughout the organization, and improve knowledge at the point of need. The confusing array of available products, access routes, and pricing plans makes it difficult to anticipate the needs of users, identify the top resources, budget effectively, make sound collection management decisions, and organize the resources effectively and seamlessly. The electronic resource marketplace requires much vigilance, considerable patience, and continuous evaluation. There are several strategies that librarians can employ to stay ahead of the electronic resource curve, including taking advantage of free trials from publishers; marketing free trials and involving users in evaluating new products; watching and testing products marketed to the clientele; agreeing to beta test new products and services; working with aggregators or republishers; joining vendor advisory boards; benchmarking institutional resources against five to eight competitors; and forming or joining a consortium for group negotiating and purchasing. This article provides a brief snapshot of leading biomedical resources; showcases several libraries that have excelled in identifying, acquiring, and organizing electronic resources; and discusses strategies and trends of potential interest to biomedical librarians, especially those working in hospital settings. PMID:10427421
Making sense of the electronic resource marketplace: trends in health-related electronic resources.
Blansit, B D; Connor, E
1999-07-01
Changes in the practice of medicine and technological developments offer librarians unprecedented opportunities to select and organize electronic resources, use the Web to deliver content throughout the organization, and improve knowledge at the point of need. The confusing array of available products, access routes, and pricing plans makes it difficult to anticipate the needs of users, identify the top resources, budget effectively, make sound collection management decisions, and organize the resources effectively and seamlessly. The electronic resource marketplace requires much vigilance, considerable patience, and continuous evaluation. There are several strategies that librarians can employ to stay ahead of the electronic resource curve, including taking advantage of free trials from publishers; marketing free trials and involving users in evaluating new products; watching and testing products marketed to the clientele; agreeing to beta test new products and services; working with aggregators or republishers; joining vendor advisory boards; benchmarking institutional resources against five to eight competitors; and forming or joining a consortium for group negotiating and purchasing. This article provides a brief snapshot of leading biomedical resources; showcases several libraries that have excelled in identifying, acquiring, and organizing electronic resources; and discusses strategies and trends of potential interest to biomedical librarians, especially those working in hospital settings.
Analysis of Human Resources Management Strategy in China Electronic Commerce Enterprises
NASA Astrophysics Data System (ADS)
Shao, Fang
The paper discussed electronic-commerce's influence on enterprise human resources management, proposed and proved the human resources management strategy which electronic commerce enterprise should adopt from recruitment strategy to training strategy, keeping talent strategy and other ways.
Implementing CORAL: An Electronic Resource Management System
ERIC Educational Resources Information Center
Whitfield, Sharon
2011-01-01
A 2010 electronic resource management survey conducted by Maria Collins of North Carolina State University and Jill E. Grogg of University of Alabama Libraries found that the top six electronic resources management priorities included workflow management, communications management, license management, statistics management, administrative…
Electronic Library: A TERI Experiment.
ERIC Educational Resources Information Center
Kar, Debal C.; Deb, Subrata; Kumar, Satish
2003-01-01
Discusses the development of Electronic Library at TERI (The Energy and Resources Institute, New Delhi). Highlights include: hardware and software used; the digital library/Virtual Electronic Library; directory of Internet journals; virtual reference resources; electronic collection/Physical Electronic Library; downloaded online full-length…
Development of Electronic Resources across Networks in Thailand.
ERIC Educational Resources Information Center
Ratchatavorn, Phandao
2002-01-01
Discusses the development of electronic resources across library networks in Thailand to meet user needs, particularly electronic journals. Topics include concerns about journal access; limited budgets for library acquisitions of journals; and sharing resources through a centralized database system that allows Web access to journals via Internet…
ERIC Educational Resources Information Center
Murray, Adam
2008-01-01
Designed to assist with the management of e-resources, electronic resource management (ERM) systems are time- and fund-consuming to purchase and maintain. Questions of system compatibility, data population, and workflow design/redesign can be difficult to answer; sometimes those answers are not what we'd prefer to hear. The two primary functions…
Shaping the Electronic Library--The UW-Madison Approach.
ERIC Educational Resources Information Center
Dean, Charles W., Ed.; Frazier, Ken; Pope, Nolan F.; Gorman, Peter C.; Dentinger, Sue; Boston, Jeanne; Phillips, Hugh; Daggett, Steven C.; Lundquist, Mitch; McClung, Mark; Riley, Curran; Allan, Craig; Waugh, David
1998-01-01
This special theme section describes the University of Wisconsin-Madison's experience building its Electronic Library. Highlights include integrating resources and services; the administrative framework; the public electronic library, including electronic publishing capability and access to World Wide Web-based and other electronic resources;…
NASA Astrophysics Data System (ADS)
Sahu, H. K.; Singh, S. N.
2015-04-01
This paper discusses and presents a comparative case study of two libraries in Pune, India, Inter-University Centre for Astronomy and Astrophysics and Information Centre and Library of National Institute of Virology (Indian Council of Medical Research). It compares how both libraries have managed their e-resource collections, including acquisitions, subscriptions, and consortia arrangements, while also developing a collection of their own resources, including pre-prints and publications, video lectures, and other materials in an institutional repository. This study illustrates how difficult it is to manage electronic resources in a developing country like India, even though electronic resources are used more than print resources. Electronic resource management can be daunting, but with a systematic approach, various problems can be solved, and use of the materials will be enhanced.
Navigating 3D electron microscopy maps with EM-SURFER.
Esquivel-Rodríguez, Juan; Xiong, Yi; Han, Xusi; Guang, Shuomeng; Christoffer, Charles; Kihara, Daisuke
2015-05-30
The Electron Microscopy DataBank (EMDB) is growing rapidly, accumulating biological structural data obtained mainly by electron microscopy and tomography, which are emerging techniques for determining large biomolecular complex and subcellular structures. Together with the Protein Data Bank (PDB), EMDB is becoming a fundamental resource of the tertiary structures of biological macromolecules. To take full advantage of this indispensable resource, the ability to search the database by structural similarity is essential. However, unlike high-resolution structures stored in PDB, methods for comparing low-resolution electron microscopy (EM) density maps in EMDB are not well established. We developed a computational method for efficiently searching low-resolution EM maps. The method uses a compact fingerprint representation of EM maps based on the 3D Zernike descriptor, which is derived from a mathematical series expansion for EM maps that are considered as 3D functions. The method is implemented in a web server named EM-SURFER, which allows users to search against the entire EMDB in real-time. EM-SURFER compares the global shapes of EM maps. Examples of search results from different types of query structures are discussed. We developed EM-SURFER, which retrieves structurally relevant matches for query EM maps from EMDB within seconds. The unique capability of EM-SURFER to detect 3D shape similarity of low-resolution EM maps should prove invaluable in structural biology.
ERIC Educational Resources Information Center
Kachaluba, Sarah Buck; Brady, Jessica Evans; Critten, Jessica
2014-01-01
This article is based on quantitative and qualitative research examining humanities scholars' understandings of the advantages and disadvantages of print versus electronic information resources. It explores how humanities' faculty members at Florida State University (FSU) use print and electronic resources, as well as how they perceive these…
Using a Decision Grid Process to Build Consensus in Electronic Resources Cancellation Decisions
ERIC Educational Resources Information Center
Foudy, Gerri; McManus, Alesia
2005-01-01
Many libraries are expending an increasing part of their collections budgets on electronic resources. At the same time many libraries, especially those which are state funded, face diminishing budgets and high rates of inflation for serials subscriptions in all formats, including electronic resources. Therefore, many libraries need to develop ways…
The utilization of poisons information resources in Australasia.
Fountain, J S; Reith, D M; Holt, A
2014-02-01
To identify poisons information resources most commonly utilized by Australasian Emergency Department staff, and examine attitudes regarding the benefits and user experience of the electronic products used. A survey tool was mailed to six Emergency Departments each in New Zealand and Australia to be answered by medical and nursing staff. Eighty six (71.7%) responses were received from the 120 survey forms sent: 70 (81%) responders were medical staff, the remainder nursing. Electronic resources were the most accessed poisons information resource in New Zealand; Australians preferring discussion with a colleague; Poisons Information Centers were the least utilized resource in both countries. With regard to electronic resources, further differences were recognized between countries in: ease of access, ease of use, quality of information and quantity of information, with New Zealand better in all four themes. New Zealand ED staff favored electronic poisons information resources while Australians preferred discussion with a colleague. That Poisons Information Centers were the least utilized resource was surprising. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Checklist Manifesto for Electronic Resources: Getting Ready for the Fiscal Year and Beyond
ERIC Educational Resources Information Center
England, Lenore; Fu, Li; Miller, Stephen
2011-01-01
Organization of electronic resources workflow is critical in the increasingly complicated and complex world of library management. A simple organizational tool that can be readily applied to electronic resources management (ERM) is the use of checklists. Based on the principles discussed in The Checklist Manifesto: How to Get Things Right, the…
E-waste management and resources recovery in France.
Vadoudi, Kiyan; Kim, Junbeum; Laratte, Bertrand; Lee, Seung-Jin; Troussier, Nadège
2015-10-01
There are various issues of concern regarding electronic waste management, such as the toxicity of hazardous materials and the collection, recycling and recovery of useful resources. To understand the fate of electronic waste after collection and recycling, a products and materials flow analysis should be performed. This is a critical need, as material resources are becoming increasingly scarce and recycling may be able to provide secondary sources for new materials in the future. In this study, we investigate electronic waste systems, specifically the resource recovery or recycling aspects, as well as mapping electronic waste flows based on collection data in France. Approximately 1,588,453 t of new electrical and electronic equipment were sold in the French market in 2010. Of this amount, 430,000 t of electronic waste were collected, with the remaining 1,128,444 t remaining in stock. Furthermore, the total recycled amounts were 354,106 t and 11,396 t, respectively. The main electronic waste materials were ferrous metals (37%), plastic (22%), aluminium (12%), copper (11%) and glass (7%). This study will contribute to developing sustainable electronic waste and resource recycling systems in France. © The Author(s) 2015.
18 CFR 390.1 - Electronic registration.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 18 Conservation of Power and Water Resources 1 2013-04-01 2013-04-01 false Electronic registration. 390.1 Section 390.1 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION, DEPARTMENT OF ENERGY PROCEDURAL RULES ELECTRONIC REGISTRATION § 390.1 Electronic registration. Any person who...
18 CFR 390.1 - Electronic registration.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 18 Conservation of Power and Water Resources 1 2011-04-01 2011-04-01 false Electronic registration. 390.1 Section 390.1 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION, DEPARTMENT OF ENERGY PROCEDURAL RULES ELECTRONIC REGISTRATION § 390.1 Electronic registration. Any person who...
18 CFR 390.1 - Electronic registration.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 18 Conservation of Power and Water Resources 1 2010-04-01 2010-04-01 false Electronic registration. 390.1 Section 390.1 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION, DEPARTMENT OF ENERGY PROCEDURAL RULES ELECTRONIC REGISTRATION § 390.1 Electronic registration. Any person who...
18 CFR 390.1 - Electronic registration.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 18 Conservation of Power and Water Resources 1 2014-04-01 2014-04-01 false Electronic registration. 390.1 Section 390.1 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION, DEPARTMENT OF ENERGY PROCEDURAL RULES ELECTRONIC REGISTRATION § 390.1 Electronic registration. Any person who...
18 CFR 390.1 - Electronic registration.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 18 Conservation of Power and Water Resources 1 2012-04-01 2012-04-01 false Electronic registration. 390.1 Section 390.1 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION, DEPARTMENT OF ENERGY PROCEDURAL RULES ELECTRONIC REGISTRATION § 390.1 Electronic registration. Any person who...
Papi, Ahmad; Ghazavi, Roghayeh; Moradi, Salimeh
2015-01-01
Understanding of the medical society's from the types of information resources for quick and easy access to information is an imperative task in medical researches and management of the treatment. The present study was aimed to determine the level of awareness of the physicians in using various electronic information resources and the factors affecting it. This study was a descriptive survey. The data collection tool was a researcher-made questionnaire. The study population included all the physicians and specialty physicians of the teaching hospitals affiliated to Isfahan University of Medical Sciences and numbered 350. The sample size based on Morgan's formula was set at 180. The content validity of the tool was confirmed by the library and information professionals and the reliability was 95%. Descriptive statistics were used including the SPSS software version 19. On reviewing the need of the physicians to obtain the information on several occasions, the need for information in conducting the researches was reported by the maximum number of physicians (91.9%) and the usage of information resources, especially the electronic resources, formed 65.4% as the highest rate with regard to meeting the information needs of the physicians. Among the electronic information databases, the maximum awareness was related to Medline with 86.5%. Among the various electronic information resources, the highest awareness (43.3%) was related to the E-journals. The highest usage (36%) was also from the same source. The studied physicians considered the most effective deterrent in the use of electronic information resources as being too busy and lack of time. Despite the importance of electronic information resources for the physician's community, there was no comprehensive knowledge of these resources. This can lead to less usage of these resources. Therefore, careful planning is necessary in the hospital libraries in order to introduce the facilities and full capabilities of the mentioned resources and methods of information retrieval.
NASA Astrophysics Data System (ADS)
Kolb, Kimberly E.; Choi, Hee-sue S.; Kaur, Balvinder; Olson, Jeffrey T.; Hill, Clayton F.; Hutchinson, James A.
2016-05-01
The US Army's Communications Electronics Research, Development and Engineering Center (CERDEC) Night Vision and Electronic Sensors Directorate (referred to as NVESD) is developing a virtual detection, recognition, and identification (DRI) testing methodology using simulated imagery as a means of augmenting the field testing component of sensor performance evaluation, which is expensive, resource intensive, time consuming, and limited to the available target(s) and existing atmospheric visibility and environmental conditions at the time of testing. Existing simulation capabilities such as the Digital Imaging Remote Sensing Image Generator (DIRSIG) and NVESD's Integrated Performance Model Image Generator (NVIPM-IG) can be combined with existing detection algorithms to reduce cost/time, minimize testing risk, and allow virtual/simulated testing using full spectral and thermal object signatures, as well as those collected in the field. NVESD has developed an end-to-end capability to demonstrate the feasibility of this approach. Simple detection algorithms have been used on the degraded images generated by NVIPM-IG to determine the relative performance of the algorithms on both DIRSIG-simulated and collected images. Evaluating the degree to which the algorithm performance agrees between simulated versus field collected imagery is the first step in validating the simulated imagery procedure.
The Relevancy of Graduate Curriculum to Human Resource Professionals' Electronic Communication.
ERIC Educational Resources Information Center
Hoell, Robert C.; Henry, Gordon O.
2003-01-01
Electronic communications of human resource professionals and the content of 23 university human resource management courses were categorized using the Human Resource Certification Institute's body of knowledge. Differences between proportion of topics discussed and topics covered in curricula suggest some topics are over- or undertaught.…
ERIC Educational Resources Information Center
Amusa, Oyintola Isiaka; Atinmo, Morayo
2016-01-01
(Purpose) This study surveyed the level of availability, use and constraints to use of electronic resources among law lecturers in Nigeria. (Methodology) Five hundred and fifty-two law lecturers were surveyed and four hundred and forty-two responded. (Results) Data analysis revealed that the level of availability of electronic resources for the…
ERIC Educational Resources Information Center
Bello, Stephen Adeyemi; Ojo, Funmilayo Roseline; Ocheje, Charles Bala
2015-01-01
Relevant electronic information resources in contemporary information age are necessity to buttress teaching and learning for effective knowledge development in educational institutions. The purpose of the study is to know the state of availability of electronic information resources in government owned secondary school libraries in Ijumu Local…
Use of traditional versus electronic medical-information resources by residents and interns.
Phua, Jason; Lim, T K
2007-05-01
Little is known about the information-seeking behaviour of junior doctors, with regard to their use of traditional versus electronic sources of information. To evaluate the amount of time junior doctors spent using various medical-information resources and how useful they perceived these resources to be. A questionnaire study of all residents and interns in a tertiary teaching hospital in July and August 2004. In total, 134 doctors returned the completed questionnaires (response rate 79.8%). They spent the most time using traditional resources like teaching sessions and print textbooks, rating them as most useful. However, electronic resources like MEDLINE, UpToDate, and online review articles also ranked highly. Original research articles were less popular. Residents and interns prefer traditional sources of medical information. Meanwhile, though some electronic resources are rated highly, more work is required to remove the barriers to evidence-based medicine.
Automatically Detecting Likely Edits in Clinical Notes Created Using Automatic Speech Recognition
Lybarger, Kevin; Ostendorf, Mari; Yetisgen, Meliha
2017-01-01
The use of automatic speech recognition (ASR) to create clinical notes has the potential to reduce costs associated with note creation for electronic medical records, but at current system accuracy levels, post-editing by practitioners is needed to ensure note quality. Aiming to reduce the time required to edit ASR transcripts, this paper investigates novel methods for automatic detection of edit regions within the transcripts, including both putative ASR errors but also regions that are targets for cleanup or rephrasing. We create detection models using logistic regression and conditional random field models, exploring a variety of text-based features that consider the structure of clinical notes and exploit the medical context. Different medical text resources are used to improve feature extraction. Experimental results on a large corpus of practitioner-edited clinical notes show that 67% of sentence-level edits and 45% of word-level edits can be detected with a false detection rate of 15%. PMID:29854187
You Have "How Many" Spreadsheets? Rethinking Electronic Resource Management
ERIC Educational Resources Information Center
Rux, Erika; Borchert, Theresa
2010-01-01
As libraries face a veritable explosion of electronic resources and as the interconnectedness of print and online resources becomes increasingly complicated, many librarians are challenged to find efficient and cost-friendly ways to manage these resources. In this article, the authors describe how a team of people from various library departments…
Hopkins, Mark E; Summers-Ables, Joy E; Clifton, Shari C; Coffman, Michael A
2011-06-01
To make electronic resources available to library users while effectively harnessing intellectual capital within the library, ultimately fostering the library's use of technology to interact asynchronously with its patrons (users). The methods used in the project included: (1) developing a new library website to facilitate the creation, management, accessibility, maintenance and dissemination of library resources; and (2) establishing ownership by those who participated in the project, while creating effective work allocation strategies through the implementation of a content management system that allowed the library to manage cost, complexity and interoperability. Preliminary results indicate that contributors to the system benefit from an increased understanding of the library's resources and add content valuable to library patrons. These strategies have helped promote the manageable creation and maintenance of electronic content in accomplishing the library's goal of interacting with its patrons. Establishment of a contributive system for adding to the library's electronic resources and electronic content has been successful. Further work will look at improving asynchronous interaction, particularly highlighting accessibility of electronic content and resources. © 2010 The authors. Health Information and Libraries Journal © 2010 Health Libraries Group.
The Michigan Electronic Library.
ERIC Educational Resources Information Center
Davidsen, Susanna L.
1997-01-01
Describes the Michigan Electronic Library (MEL), the largest evaluated and organized Web-based library of Internet resources, that was designed to provide a library of electronic information resources selected by librarians. MEL's partnership is explained, the collection is described, and future developments are considered. (LRW)
Strategic Planning for Electronic Resources Management: A Case Study at Gustavus Adolphus College
ERIC Educational Resources Information Center
Hulseberg, Anna; Monson, Sarah
2009-01-01
Electronic resources, the tools we use to manage them, and the needs and expectations of our users are constantly evolving; at the same time, the roles, responsibilities, and workflow of the library staff who manage e-resources are also in flux. Recognizing a need to be more intentional and proactive about how we manage e-resources, the…
ERM Ideas and Innovations: Digital Repository Management as ERM
ERIC Educational Resources Information Center
Pinkas, María M.; Lin, Na
2014-01-01
This article describes the application of electronic resources management (ERM) to digital repository management at the Health Sciences and Human Services Library at the University of Maryland, Baltimore. The authors discuss electronic resources management techniques, through the application of "Techniques for Electronic Management,"…
Managing Tradeoffs in the Electronic Age.
ERIC Educational Resources Information Center
Wagner, A. Ben
2003-01-01
Provides an overview of the development of electronic resources over the past three decades, discussing key features, disadvantages, and benefits of traditional online databases and CD-ROM and Web-based resources. Considers the decision to shift collections and resources toward purely digital formats, ownership of content, licensing, and user…
Make Caffeine Visible: a Fluorescent Caffeine “Traffic Light” Detector
NASA Astrophysics Data System (ADS)
Xu, Wang; Kim, Tae-Hyeong; Zhai, Duanting; Er, Jun Cheng; Zhang, Liyun; Kale, Anup Atul; Agrawalla, Bikram Keshari; Cho, Yoon-Kyoung; Chang, Young-Tae
2013-07-01
Caffeine has attracted abundant attention due to its extensive existence in beverages and medicines. However, to detect it sensitively and conveniently remains a challenge, especially in resource-limited regions. Here we report a novel aqueous phase fluorescent caffeine sensor named Caffeine Orange which exhibits 250-fold fluorescence enhancement upon caffeine activation and high selectivity. Nuclear magnetic resonance spectroscopy and Fourier transform infrared spectroscopy indicate that π-stacking and hydrogen-bonding contribute to their interactions while dynamic light scattering and transmission electron microscopy experiments demonstrate the change of Caffeine Orange ambient environment induces its fluorescence emission. To utilize this probe in real life, we developed a non-toxic caffeine detection kit and tested it for caffeine quantification in various beverages. Naked-eye sensing of various caffeine concentrations was possible based on color changes upon irradiation with a laser pointer. Lastly, we performed the whole system on a microfluidic device to make caffeine detection quick, sensitive and automated.
Egle, Jonathan P; Smeenge, David M; Kassem, Kamal M; Mittal, Vijay K
2015-01-01
Electronic sources of medical information are plentiful, and numerous studies have demonstrated the use of the Internet by patients and the variable reliability of these sources. Studies have investigated neither the use of web-based resources by residents, nor the reliability of the information available on these websites. A web-based survey was distributed to surgical residents in Michigan and third- and fourth-year medical students at an American allopathic and osteopathic medical school and a Caribbean allopathic school regarding their preferred sources of medical information in various situations. A set of 254 queries simulating those faced by medical trainees on rounds, on a written examination, or during patient care was developed. The top 5 electronic resources cited by the trainees were evaluated for their ability to answer these questions accurately, using standard textbooks as the point of reference. The respondents reported a wide variety of overall preferred resources. Most of the 73 responding medical trainees favored textbooks or board review books for prolonged studying, but electronic resources are frequently used for quick studying, clinical decision-making questions, and medication queries. The most commonly used electronic resources were UpToDate, Google, Medscape, Wikipedia, and Epocrates. UpToDate and Epocrates had the highest percentage of correct answers (47%) and Wikipedia had the lowest (26%). Epocrates also had the highest percentage of wrong answers (30%), whereas Google had the lowest percentage (18%). All resources had a significant number of questions that they were unable to answer. Though hardcopy books have not been completely replaced by electronic resources, more than half of medical students and nearly half of residents prefer web-based sources of information. For quick questions and studying, both groups prefer Internet sources. However, the most commonly used electronic resources fail to answer clinical queries more than half of the time and have an alarmingly high rate of inaccurate information. Copyright © 2014 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.
JSC earth resources data analysis capabilities available to EOD revision B
NASA Technical Reports Server (NTRS)
1974-01-01
A list and summary description of all Johnson Space Center electronic laboratory and photographic laboratory capabilities available to earth resources division personnel for processing earth resources data are provided. The electronic capabilities pertain to those facilities and systems that use electronic and/or photographic products as output. The photographic capabilities pertain to equipment that uses photographic images as input and electronic and/or table summarizes processing steps. A general hardware description is presented for each of the data processing systems, and the titles of computer programs are used to identify the capabilities and data flow.
30 CFR 1210.54 - Must I submit this royalty report electronically?
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 3 2011-07-01 2011-07-01 false Must I submit this royalty report electronically? 1210.54 Section 1210.54 Mineral Resources OFFICE OF SURFACE MINING RECLAMATION AND ENFORCEMENT, DEPARTMENT OF THE INTERIOR Natural Resources Revenue FORMS AND REPORTS Royalty Reports-Oil, Gas, and...
Model for Presenting Resources in Scholar's Portal
ERIC Educational Resources Information Center
Feeney, Mary; Newby, Jill
2005-01-01
Presenting electronic resources to users through a federated search engine introduces unique opportunities and challenges to libraries. This article reports on the decision-making tools and processes used for selecting collections of electronic resources by a project team at the University of Arizona (UA) Libraries for the Association of Research…
Electronic Reference Works and Library Budgeting Dilemma
ERIC Educational Resources Information Center
Lawal, Ibironke O.
2007-01-01
The number of electronic resources has climbed up steadily in recent times. Some of these e-resources are reference sources, mostly in Science, Technology and Medicine (STM), which publishers convert to electronic for obvious reasons. The library budgets for materials usually have two main lines, budget for one time purchase (monographs) and…
ERIC Educational Resources Information Center
McDowell, Liz
2002-01-01
This qualitative interview-based study examines lecturer perspectives on the roles of electronic information resources in undergraduate education. Highlights include electronic academic libraries; changes toward more constructivist approaches to learning; information quality on the Web; plagiarism; information use; information literacy; and…
ERIC Educational Resources Information Center
Hartnett, Eric; Price, Apryl; Smith, Jane; Barrett, Michael
2010-01-01
Over the past few years, Texas A&M University (TAMU) has searched for a way to administer its electronic subscriptions as well as the electronic subscriptions shared among the TAMU System. In this article, we address our attempts to implement an effective electronic resource management system (ERMS), both for subscriptions on the main campus…
ERIC Educational Resources Information Center
Page, Tom; Thorsteinsson, Gisli
2006-01-01
The work outlined here provides a comprehensive report and formative observations of the development and implementation of hypermedia resources for learning and teaching used in conjunction with a managed learning environment (MLE). These resources are used to enhance teaching and learning of an electronics module in product design at final year…
ERIC Educational Resources Information Center
Goodman, Kenneth; Grad, Roland; Pluye, Pierre; Nowacki, Amy; Hickner, John
2012-01-01
Introduction: Electronic knowledge resources have the potential to rapidly provide answers to clinicians' questions. We sought to determine clinicians' reasons for searching these resources, the rate of finding relevant information, and the perceived clinical impact of the information they retrieved. Methods: We asked general internists, family…
ERIC Educational Resources Information Center
White, Marilyn; Sanders, Susan
2009-01-01
The Information Services Division (ISD) of the National Institute of Standards and Technology (NIST) positioned itself to successfully implement an electronic resources management system. This article highlights the ISD's unique ability to "team" across the organization to realize a common goal, develop leadership qualities in support of…
Specializing network analysis to detect anomalous insider actions
Chen, You; Nyemba, Steve; Zhang, Wen; Malin, Bradley
2012-01-01
Collaborative information systems (CIS) enable users to coordinate efficiently over shared tasks in complex distributed environments. For flexibility, they provide users with broad access privileges, which, as a side-effect, leave such systems vulnerable to various attacks. Some of the more damaging malicious activities stem from internal misuse, where users are authorized to access system resources. A promising class of insider threat detection models for CIS focuses on mining access patterns from audit logs, however, current models are limited in that they assume organizations have significant resources to generate label cases for training classifiers or assume the user has committed a large number of actions that deviate from “normal” behavior. In lieu of the previous assumptions, we introduce an approach that detects when specific actions of an insider deviate from expectation in the context of collaborative behavior. Specifically, in this paper, we introduce a specialized network anomaly detection model, or SNAD, to detect such events. This approach assesses the extent to which a user influences the similarity of the group of users that access a particular record in the CIS. From a theoretical perspective, we show that the proposed model is appropriate for detecting insider actions in dynamic collaborative systems. From an empirical perspective, we perform an extensive evaluation of SNAD with the access logs of two distinct environments: the patient record access logs a large electronic health record system (6,015 users, 130,457 patients and 1,327,500 accesses) and the editing logs of Wikipedia (2,394,385 revisors, 55,200 articles and 6,482,780 revisions). We compare our model with several competing methods and demonstrate SNAD is significantly more effective: on average it achieves 20–30% greater area under an ROC curve. PMID:23399988
NASA Parts Selection List (NPSL) WWW Site http://nepp.nasa.gov/npsl
NASA Technical Reports Server (NTRS)
Brusse, Jay
2000-01-01
The NASA Parts Selection List (NPSL) is an on-line resource for electronic parts selection tailored for use by spaceflight projects. The NPSL provides a list of commonly used electronic parts that have a history of satisfactory use in spaceflight applications. The objective of this www site is to provide NASA projects, contractors, university experimenters, et al with an easy to use resource that provides a baseline of electronic parts from which designers are encouraged to select. The NPSL is an ongoing resource produced by Code 562 in support of the NASA HQ funded NASA Electronic Parts and Packaging (NEPP) Program. The NPSL is produced as an electronic format deliverable made available via the referenced www site administered by Code 562. The NPSL does not provide information pertaining to patented or proprietary information. All of the information contained in the NPSL is available through various other public domain resources such as US Military procurement specifications for electronic parts, NASA GSFC's Preferred Parts List (PPL-21), and NASA's Standard Parts List (MIL-STD975).
Principles for new optical techniques in medical diagnostics for mHealth applications
NASA Astrophysics Data System (ADS)
Balsam, Joshua Michael
Medical diagnostics is a critical element of effective medical treatment. However, many modern and emerging diagnostic technologies are not affordable or compatible with the needs and conditions found in low-income and middle-income countries and regions. Resource-poor areas require low-cost, robust, easy-to-use, and portable diagnostics devices compatible with telemedicine (i.e. mHealth) that can be adapted to meet diverse medical needs. Many suitable devices will need to be based on optical technologies, which are used for many types of biological analyses. This dissertation describes the fabrication and detection principles for several low-cost optical technologies for mHealth applications including: (1) a webcam based multi-wavelength fluorescence plate reader, (2) a lens-free optical detector used for the detection of Botulinum A neurotoxin activity, (3) a low cost micro-array reader that allows the performance of typical fluorescence based assays demonstrated for the detection of the toxin staphylococcal enterotoxin (SEB), and (4) a wide-field flow cytometer for high throughput detection of fluorescently labeled rare cells. This dissertation discusses how these technologies can be harnessed using readily available consumer electronics components such as webcams, cell phones, CCD cameras, LEDs, and laser diodes. There are challenges in developing devices with sufficient sensitivity and specificity, and approaches are presented to overcoming these challenges to create optical detectors that can serve as low cost medical diagnostics in resource-poor settings for mHealth.
Mediagraphy: Print and Nonprint Resources.
ERIC Educational Resources Information Center
Educational Media and Technology Yearbook, 1998
1998-01-01
Lists educational media-related journals, books, ERIC documents, journal articles, and nonprint resources classified by Artificial Intelligence, Robotics, Electronic Performance Support Systems; Computer-Assisted Instruction; Distance Education; Educational Research; Educational Technology; Electronic Publishing; Information Science and…
Gilman, Robert H; Tielsch, James M; Steinhoff, Mark; Figueroa, Dante; Rodriguez, Shalim; Caffo, Brian; Tracey, Brian; Elhilali, Mounya; West, James; Checkley, William
2012-01-01
Introduction WHO case management algorithm for paediatric pneumonia relies solely on symptoms of shortness of breath or cough and tachypnoea for treatment and has poor diagnostic specificity, tends to increase antibiotic resistance. Alternatives, including oxygen saturation measurement, chest ultrasound and chest auscultation, exist but with potential disadvantages. Electronic auscultation has potential for improved detection of paediatric pneumonia but has yet to be standardised. The authors aim to investigate the use of electronic auscultation to improve the specificity of the current WHO algorithm in developing countries. Methods This study is designed to test the hypothesis that pulmonary pathology can be differentiated from normal using computerised lung sound analysis (CLSA). The authors will record lung sounds from 600 children aged ≤5 years, 100 each with consolidative pneumonia, diffuse interstitial pneumonia, asthma, bronchiolitis, upper respiratory infections and normal lungs at a children's hospital in Lima, Peru. The authors will compare CLSA with the WHO algorithm and other detection approaches, including physical exam findings, chest ultrasound and microbiologic testing to construct an improved algorithm for pneumonia diagnosis. Discussion This study will develop standardised methods for electronic auscultation and chest ultrasound and compare their utility for detection of pneumonia to standard approaches. Utilising signal processing techniques, the authors aim to characterise lung sounds and through machine learning, develop a classification system to distinguish pathologic sounds. Data will allow a better understanding of the benefits and limitations of novel diagnostic techniques in paediatric pneumonia. PMID:22307098
Video Killed the Radio Star: Language Students' Use of Electronic Resources-Reading or Viewing?
ERIC Educational Resources Information Center
Kiliçkaya, Ferit
2016-01-01
The current study aimed to investigate language students' use of print and electronic resources for their research papers required in research techniques class, focusing on which reading strategies they used while reading these resources. The participants of the study were 90 sophomore students enrolled in the research techniques class offered at…
ERIC Educational Resources Information Center
Downey, Kay
2012-01-01
Kent State University has developed a centralized system that manages the communication and work related to the review and selection of commercially available electronic resources. It is an automated system that tracks the review process, provides selectors with price and trial information, and compiles reviewers' feedback about the resource. It…
Connecting Print and Electronic Titles: An Integrated Approach at the University of Nebraska-Lincoln
ERIC Educational Resources Information Center
Wolfe, Judith; Konecky, Joan Latta; Boden, Dana W. R.
2011-01-01
Libraries make heavy investments in electronic resources, with many of these resources reflecting title changes, bundled subsets, or content changes of formerly print material. These changes can distance the electronic format from its print origins, creating discovery and access issues. A task force was formed to explore the enhancement of catalog…
ERIC Educational Resources Information Center
Glogoff, Stuart
1995-01-01
Discusses two Electronic Library Education Centers (ELECs) created at the University of Arizona to improve library instruction in the use of online resources. Examines costs of developing ELECs; technical changes experienced; and benefits to users and librarians. A sidebar by Abbie J. Basile identifies Internet resources for planning and/or…
Pelzer, N L; Wiese, W H; Leysen, J M
1998-07-01
Veterinary medical students at Iowa State University were surveyed in January of 1997 to determine their general use of the Veterinary Medical Library and how they sought information in an electronic environment. Comparisons were made between this study and one conducted a decade ago to determine the effect of the growth in electronic resources on student library use and information-seeking behavior. The basic patterns of student activities in the library, resources used to find current information, and resources anticipated for future education needs remained unchanged. The 1997 students used the library most frequently for photocopying, office supplies, and studying coursework; they preferred textbooks and handouts as sources of current information. However, when these students went beyond textbooks and handouts to seek current information, a major shift was seen from the use of print indexes and abstracts in 1987 towards the use of computerized indexes and other electronic resources in 1997. Almost 60% of the students reported using the Internet for locating current information. Overall use of electronic materials was highest among a group of students receiving the problem-based learning method of instruction. Most of the students surveyed in 1997 indicated that electronic resources would have some degree of importance to them for future education needs. The electronic environment has provided new opportunities for information professionals to help prepare future veterinarians, some of whom will be practicing in remote geographical locations, to access the wealth of information and services available on the Internet and Web.
Water Detection Based on Object Reflections
NASA Technical Reports Server (NTRS)
Rankin, Arturo L.; Matthies, Larry H.
2012-01-01
Water bodies are challenging terrain hazards for terrestrial unmanned ground vehicles (UGVs) for several reasons. Traversing through deep water bodies could cause costly damage to the electronics of UGVs. Additionally, a UGV that is either broken down due to water damage or becomes stuck in a water body during an autonomous operation will require rescue, potentially drawing critical resources away from the primary operation and increasing the operation cost. Thus, robust water detection is a critical perception requirement for UGV autonomous navigation. One of the properties useful for detecting still water bodies is that their surface acts as a horizontal mirror at high incidence angles. Still water bodies in wide-open areas can be detected by geometrically locating the exact pixels in the sky that are reflecting on candidate water pixels on the ground, predicting if ground pixels are water based on color similarity to the sky and local terrain features. But in cluttered areas where reflections of objects in the background dominate the appearance of the surface of still water bodies, detection based on sky reflections is of marginal value. Specifically, this software attempts to solve the problem of detecting still water bodies on cross-country terrain in cluttered areas at low cost.
Dollar, Daniel M; Gallagher, John; Glover, Janis; Marone, Regina Kenny; Crooker, Cynthia
2007-04-01
To support migration from print to electronic resources, the Cushing/Whitney Medical Library at Yale University reorganized its Technical Services Department to focus on managing electronic resources. The library hired consultants to help plan the changes and to present recommendations for integrating electronic resource management into every position. The library task force decided to focus initial efforts on the periodical collection. To free staff time to devote to electronic journals, most of the print subscriptions were switched to online only and new workflows were developed for e-journals. Staff learned new responsibilities such as activating e-journals, maintaining accurate holdings information in the online public access catalog and e-journals database ("electronic shelf reading"), updating the link resolver knowledgebase, and troubleshooting. All of the serials team members now spend significant amounts of time managing e-journals. The serials staff now spends its time managing the materials most important to the library's clientele (e-journals and databases). The team's proactive approach to maintenance work and rapid response to reported problems should improve patrons' experiences using e-journals. The library is taking advantage of new technologies such as an electronic resource management system, and library workflows and procedures will continue to evolve as technology changes.
Dollar, Daniel M.; Gallagher, John; Glover, Janis; Marone, Regina Kenny; Crooker, Cynthia
2007-01-01
Objective: To support migration from print to electronic resources, the Cushing/Whitney Medical Library at Yale University reorganized its Technical Services Department to focus on managing electronic resources. Methods: The library hired consultants to help plan the changes and to present recommendations for integrating electronic resource management into every position. The library task force decided to focus initial efforts on the periodical collection. To free staff time to devote to electronic journals, most of the print subscriptions were switched to online only and new workflows were developed for e-journals. Results: Staff learned new responsibilities such as activating e-journals, maintaining accurate holdings information in the online public access catalog and e-journals database (“electronic shelf reading”), updating the link resolver knowledgebase, and troubleshooting. All of the serials team members now spend significant amounts of time managing e-journals. Conclusions: The serials staff now spends its time managing the materials most important to the library's clientele (e-journals and databases). The team's proactive approach to maintenance work and rapid response to reported problems should improve patrons' experiences using e-journals. The library is taking advantage of new technologies such as an electronic resource management system, and library workflows and procedures will continue to evolve as technology changes. PMID:17443247
Selection of Electronic Resources.
ERIC Educational Resources Information Center
Weathers, Barbara
1998-01-01
Discusses the impact of electronic resources on collection development; selection of CD-ROMs, (platform, speed, video and sound, networking capability, installation and maintenance); selection of laser disks; and Internet evaluation (accuracy of content, authority, objectivity, currency, technical characteristics). Lists Web sites for evaluating…
Luke, Stephen; Fountain, John S; Reith, David M; Braitberg, George; Cruickshank, Jaycen
2014-10-01
ED staff use a range of poisons information resources of varying type and quality. The present study aims to identify those resources utilised in the state of Victoria, Australia, and assess opinion of the most used electronic products. A previously validated self-administered survey was conducted in 15 EDs, with 10 questionnaires sent to each. The survey was then repeated following the provision of a 4-month period of access to Toxinz™, an Internet poisons information product novel to the region. The study was conducted from December 2010 to August 2011. There were 117 (78%) and 48 (32%) responses received from the first and second surveys, respectively, a 55% overall response rate. No statistically significant differences in professional group, numbers of poisoned patients seen or resource type accessed were identified between studies. The electronic resource most used in the first survey was Poisindex® (48.68%) and Toxinz™ (64.1%) in the second. There were statistically significant (P < 0.01) improvements in satisfaction in 26 of 42 questions between surveys, and no decrements. Although the majority of responders possessed mobile devices, less than half used them for poisons information but would do so if a reputable product was available. The order of poisons information sources most utilised was: consultation with a colleague, in-house protocols and electronic resources. There was a significant difference in satisfaction with electronic poisons information resources and a movement away from existing sources when choice was provided. Interest in increased use of mobile solutions was identified. © 2014 Australasian College for Emergency Medicine and Australasian Society for Emergency Medicine.
ERIC Educational Resources Information Center
Noh, Younghee
2010-01-01
This study aimed to improve the current state of electronic resource evaluation in libraries. While the use of Web DB, e-book, e-journal, and other e-resources such as CD-ROM, DVD, and micro materials is increasing in libraries, their use is not comprehensively factored into the general evaluation of libraries and may diminish the reliability of…
Electronic Commerce Resource Centers. An Industry--University Partnership.
ERIC Educational Resources Information Center
Gulledge, Thomas R.; Sommer, Rainer; Tarimcilar, M. Murat
1999-01-01
Electronic Commerce Resource Centers focus on transferring emerging technologies to small businesses through university/industry partnerships. Successful implementation hinges on a strategic operating plan, creation of measurable value for customers, investment in customer-targeted training, and measurement of performance outputs. (SK)
An Electronic Worker Service System of the Pig House Based on ATmega16
NASA Astrophysics Data System (ADS)
Li, Liu-An; Jin, Tian-Ming; Yu, Ya-Ping; Zhang, Guo-Qiang; Hong, Tao
Pork is very important for people in daily life. Quality of livestock environment is closely related to the growth of animals. To improve environmental quality, the paper designed an electronic worker service system of the pig house based on ATmega16, which consisted of 6 detection modules, wireless data collecting, GSM, time circuit, display, anti-th alarm and music player, etc. A small LAN was constructed by wireless transceiver module to test and collect data of temperature, humidity and harmful gas concentration in the pig house. If one detection point exists that harmful pollutant gases concentration exceeds the standard value, GSM module took a message for livestock farmers, so that farmers can promptly arrive at the pig house to ventilate or deal with manure in the pig house, which can effectively prevent from bad things. Time of pyroelectric detector deployment can be freely set, and intrusion information was timely sent to the users. The anti-th alarm function was achieved by the auxiliary light. The music playing module is open by timer module in order to soothing pigs' life state. All are suitable for small farms and can save human resources.
Rasooly, Reuven; Bruck, Hugh Alan; Balsam, Joshua; Prickril, Ben; Ossandon, Miguel; Rasooly, Avraham
2016-05-17
Resource-poor countries and regions require effective, low-cost diagnostic devices for accurate identification and diagnosis of health conditions. Optical detection technologies used for many types of biological and clinical analysis can play a significant role in addressing this need, but must be sufficiently affordable and portable for use in global health settings. Most current clinical optical imaging technologies are accurate and sensitive, but also expensive and difficult to adapt for use in these settings. These challenges can be mitigated by taking advantage of affordable consumer electronics mobile devices such as webcams, mobile phones, charge-coupled device (CCD) cameras, lasers, and LEDs. Low-cost, portable multi-wavelength fluorescence plate readers have been developed for many applications including detection of microbial toxins such as C. Botulinum A neurotoxin, Shiga toxin, and S. aureus enterotoxin B (SEB), and flow cytometry has been used to detect very low cell concentrations. However, the relatively low sensitivities of these devices limit their clinical utility. We have developed several approaches to improve their sensitivity presented here for webcam based fluorescence detectors, including (1) image stacking to improve signal-to-noise ratios; (2) lasers to enable fluorescence excitation for flow cytometry; and (3) streak imaging to capture the trajectory of a single cell, enabling imaging sensors with high noise levels to detect rare cell events. These approaches can also help to overcome some of the limitations of other low-cost optical detection technologies such as CCD or phone-based detectors (like high noise levels or low sensitivities), and provide for their use in low-cost medical diagnostics in resource-poor settings.
Rasooly, Reuven; Bruck, Hugh Alan; Balsam, Joshua; Prickril, Ben; Ossandon, Miguel; Rasooly, Avraham
2016-01-01
Resource-poor countries and regions require effective, low-cost diagnostic devices for accurate identification and diagnosis of health conditions. Optical detection technologies used for many types of biological and clinical analysis can play a significant role in addressing this need, but must be sufficiently affordable and portable for use in global health settings. Most current clinical optical imaging technologies are accurate and sensitive, but also expensive and difficult to adapt for use in these settings. These challenges can be mitigated by taking advantage of affordable consumer electronics mobile devices such as webcams, mobile phones, charge-coupled device (CCD) cameras, lasers, and LEDs. Low-cost, portable multi-wavelength fluorescence plate readers have been developed for many applications including detection of microbial toxins such as C. Botulinum A neurotoxin, Shiga toxin, and S. aureus enterotoxin B (SEB), and flow cytometry has been used to detect very low cell concentrations. However, the relatively low sensitivities of these devices limit their clinical utility. We have developed several approaches to improve their sensitivity presented here for webcam based fluorescence detectors, including (1) image stacking to improve signal-to-noise ratios; (2) lasers to enable fluorescence excitation for flow cytometry; and (3) streak imaging to capture the trajectory of a single cell, enabling imaging sensors with high noise levels to detect rare cell events. These approaches can also help to overcome some of the limitations of other low-cost optical detection technologies such as CCD or phone-based detectors (like high noise levels or low sensitivities), and provide for their use in low-cost medical diagnostics in resource-poor settings. PMID:27196933
Reconfigurable acquisition system with integrated optics for a portable flow cytometer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kirleis, Matthew A., E-mail: matthew.kirleis@nrl.navy.mil; Mathews, Scott A.; Verbarg, Jasenka
2013-11-15
Portable and inexpensive scientific instruments that are capable of performing point of care diagnostics are needed for applications such as disease detection and diagnosis in resource-poor settings, for water quality and food supply monitoring, and for biosurveillance activities in autonomous vehicles. In this paper, we describe the development of a compact flow cytometer built from three separate, customizable, and interchangeable modules. The instrument as configured in this work is being developed specifically for the detection of selected Centers for Disease Control (CDC) category B biothreat agents through a bead-based assay: E. coli O157:H7, Salmonella, Listeria, and Shigella. It has two-colormore » excitation, three-color fluorescence and light scattering detection, embedded electronics, and capillary based flow. However, these attributes can be easily modified for other applications such as cluster of differentiation 4 (CD4) counting. Proof of concept is demonstrated through a 6-plex bead assay with the results compared to a commercially available benchtop-sized instrument.« less
Reconfigurable acquisition system with integrated optics for a portable flow cytometer.
Kirleis, Matthew A; Mathews, Scott A; Verbarg, Jasenka; Erickson, Jeffrey S; Piqué, Alberto
2013-11-01
Portable and inexpensive scientific instruments that are capable of performing point of care diagnostics are needed for applications such as disease detection and diagnosis in resource-poor settings, for water quality and food supply monitoring, and for biosurveillance activities in autonomous vehicles. In this paper, we describe the development of a compact flow cytometer built from three separate, customizable, and interchangeable modules. The instrument as configured in this work is being developed specifically for the detection of selected Centers for Disease Control (CDC) category B biothreat agents through a bead-based assay: E. coli O157:H7, Salmonella, Listeria, and Shigella. It has two-color excitation, three-color fluorescence and light scattering detection, embedded electronics, and capillary based flow. However, these attributes can be easily modified for other applications such as cluster of differentiation 4 (CD4) counting. Proof of concept is demonstrated through a 6-plex bead assay with the results compared to a commercially available benchtop-sized instrument.
Chemical Detection and Identification Techniques for Exobiology Flight Experiments
NASA Technical Reports Server (NTRS)
Kojiro, Daniel R.; Sheverev, Valery A.; Khromov, Nikolai A.
2002-01-01
Exobiology flight experiments require highly sensitive instrumentation for in situ analysis of the volatile chemical species that occur in the atmospheres and surfaces of various bodies within the solar system. The complex mixtures encountered place a heavy burden on the analytical Instrumentation to detect and identify all species present. The minimal resources available onboard for such missions mandate that the instruments provide maximum analytical capabilities with minimal requirements of volume, weight and consumables. Advances in technology may be achieved by increasing the amount of information acquired by a given technique with greater analytical capabilities and miniaturization of proven terrestrial technology. We describe here methods to develop analytical instruments for the detection and identification of a wide range of chemical species using Gas Chromatography. These efforts to expand the analytical capabilities of GC technology are focused on the development of detectors for the GC which provide sample identification independent of the GC retention time data. A novel new approach employs Penning Ionization Electron Spectroscopy (PIES).
Reconfigurable acquisition system with integrated optics for a portable flow cytometer
NASA Astrophysics Data System (ADS)
Kirleis, Matthew A.; Mathews, Scott A.; Verbarg, Jasenka; Erickson, Jeffrey S.; Piqué, Alberto
2013-11-01
Portable and inexpensive scientific instruments that are capable of performing point of care diagnostics are needed for applications such as disease detection and diagnosis in resource-poor settings, for water quality and food supply monitoring, and for biosurveillance activities in autonomous vehicles. In this paper, we describe the development of a compact flow cytometer built from three separate, customizable, and interchangeable modules. The instrument as configured in this work is being developed specifically for the detection of selected Centers for Disease Control (CDC) category B biothreat agents through a bead-based assay: E. coli O157:H7, Salmonella, Listeria, and Shigella. It has two-color excitation, three-color fluorescence and light scattering detection, embedded electronics, and capillary based flow. However, these attributes can be easily modified for other applications such as cluster of differentiation 4 (CD4) counting. Proof of concept is demonstrated through a 6-plex bead assay with the results compared to a commercially available benchtop-sized instrument.
Revolution or Revelation? Acquisitions for the Digital Library
ERIC Educational Resources Information Center
Morris, Kathleen; Larson, Betsy
2006-01-01
Libraries are responding to customer preferences for electronic research materials through the acquisition and management of these products. Electronic resources have significantly different characteristics than print resources when it comes to technical services management. This paper addresses aspects of a corporate research library's evaluation…
Remote detection of electronic devices
Judd, Stephen L [Los Alamos, NM; Fortgang, Clifford M [Los Alamos, NM; Guenther, David C [Los Alamos, NM
2012-09-25
An apparatus and method for detecting solid-state electronic devices are described. Non-linear junction detection techniques are combined with spread-spectrum encoding and cross correlation to increase the range and sensitivity of the non-linear junction detection and to permit the determination of the distances of the detected electronics. Nonlinear elements are detected by transmitting a signal at a chosen frequency and detecting higher harmonic signals that are returned from responding devices.
Electronic Resources: Selection and Bibliographic Control.
ERIC Educational Resources Information Center
Pattie, Ling-yuh W., Ed.; Cox, Bonnie Jean, Ed.
This book is a baseline guide for professionals and library school students on issues that concern the selection and bibliographic control of electronic resources, from both conceptual and pragmatic standpoints. The book includes the following articles: (1) "Foreward" (Lois Mai Chan); (2) "Introduction" (Ling-yuh W. (Miko)…
Licensing and Negotiations for Electronic Content
ERIC Educational Resources Information Center
Crawford, Amy R.
2008-01-01
This article provides an overview of the basic characteristics of database, or eContent, license agreements, defines general licensing terms, maps the anatomy of an electronic resources subscription agreement, and discusses negotiating skills and techniques for library staff. (Contains a list of additional resources and a sample agreement.)
Introduction of home electronics for the future
NASA Astrophysics Data System (ADS)
Yoshimoto, Hideyuki; Shirai, Iwao
Development of electronics has accelerated the automation and labor saving at factories and offices. Home electronics is also expected to be needed more and more in Japan towards the 21st century, as the advanced information society and the elderly society will be accelerated, and women's participation in social affairs will be increased. Resources Council, which is the advisory organ of the Minister of State for Science and Technology, forecast to what extent home electronics will be popularized by the year of 2010. The Council expected to promote home electronics, because resource and energy saving should be accelerated and people should enjoy much more their individual lives at home.
Robertson, Jane; Moxey, Annette J; Newby, David A; Gillies, Malcolm B; Williamson, Margaret; Pearson, Sallie-Anne
2011-01-01
Background. Investments in eHealth worldwide have been mirrored in Australia, with >90% of general practices computerized. Recent eHealth incentives promote the use of up to date electronic information sources relevant to general practice with flexibility in mode of access. Objective. To determine GPs’ access to and use of electronic information sources and computerized clinical decision support systems (CDSSs) for prescribing. Methods. Semi-structured interviews were conducted with 18 experienced GPs and nine GP trainees in New South Wales, Australia in 2008. A thematic analysis of interview transcripts was undertaken. Results. Information needs varied with clinical experience, and people resources (specialists, GP peers and supervisors for trainees) were often preferred over written formats. Experienced GPs used a small number of electronic resources and accessed them infrequently. Familiarity from training and early clinical practice and easy access were dominant influences on resource use. Practice time constraints meant relevant information needed to be readily accessible during consultations, requiring integration or direct access from prescribing software. Quality of electronic resource content was assumed and cost a barrier for some GPs. Conclusions. The current Australian practice incentives do not prescribe which information resources GPs should use. Without integration into practice computing systems, uptake and routine use seem unlikely. CDSS developments must recognize the time pressures of practice, preference for integration and cost concerns. Minimum standards are required to ensure that high-quality information resources are integrated and regularly updated. Without standards, the anticipated benefits of computerization on patient safety and health outcomes will be uncertain. PMID:21109619
Note: An improved 3D imaging system for electron-electron coincidence measurements
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lin, Yun Fei; Lee, Suk Kyoung; Adhikari, Pradip
We demonstrate an improved imaging system that can achieve highly efficient 3D detection of two electrons in coincidence. The imaging system is based on a fast frame complementary metal-oxide semiconductor camera and a high-speed waveform digitizer. We have shown previously that this detection system is capable of 3D detection of ions and electrons with good temporal and spatial resolution. Here, we show that with a new timing analysis algorithm, this system can achieve an unprecedented dead-time (<0.7 ns) and dead-space (<1 mm) when detecting two electrons. A true zero dead-time detection is also demonstrated.
Note: An improved 3D imaging system for electron-electron coincidence measurements
NASA Astrophysics Data System (ADS)
Lin, Yun Fei; Lee, Suk Kyoung; Adhikari, Pradip; Herath, Thushani; Lingenfelter, Steven; Winney, Alexander H.; Li, Wen
2015-09-01
We demonstrate an improved imaging system that can achieve highly efficient 3D detection of two electrons in coincidence. The imaging system is based on a fast frame complementary metal-oxide semiconductor camera and a high-speed waveform digitizer. We have shown previously that this detection system is capable of 3D detection of ions and electrons with good temporal and spatial resolution. Here, we show that with a new timing analysis algorithm, this system can achieve an unprecedented dead-time (<0.7 ns) and dead-space (<1 mm) when detecting two electrons. A true zero dead-time detection is also demonstrated.
The Acquisition and Management of Electronic Resources: Can Use Justify Cost?
ERIC Educational Resources Information Center
Koehn, Shona L.; Hawamdeh, Suliman
2010-01-01
As library collections increasingly become digital, libraries are faced with many challenges regarding the acquisition and management of electronic resources. Some of these challenges include copyright and fair use, the first-sale doctrine, licensing versus ownership, digital preservation, long-term archiving, and, most important, the issue of…
18 CFR 35.7 - Electronic filing requirements.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 18 Conservation of Power and Water Resources 1 2010-04-01 2010-04-01 false Electronic filing requirements. 35.7 Section 35.7 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION, DEPARTMENT OF ENERGY REGULATIONS UNDER THE FEDERAL POWER ACT FILING OF RATE SCHEDULES AND TARIFFS Application...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-28
... and resources by working across public, private, and civil sectors to further HUD's mission. IPI works... alignment of cross-sector resources and ideas. Members of affected public: Individuals. Estimation of the... Collection for Public Comment: Electronic Stakeholder Survey--Office for International and Philanthropic...
Somewhere over the Verde Rainbow
ERIC Educational Resources Information Center
Ekart, Donna F.
2008-01-01
When the electronic resource management system (ERM) at Kansas State University Libraries suffered a horrible data loss, the "contract db" presented a challenge for the librarians responsible for electronic resources. It was a decent data repository, but it had no ability to manage the tangled process of licensing, acquiring, activating,…
Telemedicine and cardiac implants: what is the benefit?
Varma, Niraj; Ricci, Renato Pietro
2013-01-01
Cardiac implantable electronic devices are increasing in prevalence. The post-implant follow-up is important for monitoring both device function and patient condition. However, practice is inconsistent. For example, ICD follow-up schedules vary from 3 monthly to yearly according to facility and physician preference and availability of resources. Recommended follow-up schedules impose significant burden. Importantly, no surveillance occurs between follow-up visits. In contrast, implantable devices with automatic remote monitoring capability provide a means for performing constant surveillance, with the ability to identify salient problems rapidly. Remote home monitoring reduces the volume of device clinic visits and provides early detection of patient and/or system problems. PMID:23211231
Mendoza-Gallegos, Roberto A; Rios, Amelia; Garcia-Cordero, Jose L
2018-05-01
The polymerase chain reaction (PCR) is a sought-after nucleic acid amplification technique used in the detection of several diseases. However, one of the main limitations of this and other nucleic acid amplification assays is the complexity, size, maintenance, and cost of their operational instrumentation. This limits the use of PCR applications in settings that cannot afford the instruments but that may have access to basic electrical, electronic, and optical components and the expertise to build them. To provide a more accessible platform, we developed a low-cost, palm-size, and portable instrument to perform real-time PCR (qPCR). The thermocycler leverages a copper-sheathed power resistor and a computer fan, in tandem with basic electronic components controlled from a single-board computer. The instrument incorporates a 3D-printed chassis and a custom-made fluorescence optical setup based on a CMOS camera and a blue LED. Results are displayed in real-time on a tablet. We also fabricated simple acrylic microdevices consisting of four wells (2 μL in volume each) where PCR reactions take place. To test our instrument, we performed qPCR on a series of cDNA dilutions spanning 4 orders of magnitude, achieving similar limits of detection as those achieved by a benchtop thermocycler. We envision our instrument being utilized to enable routine monitoring and diagnosis of certain diseases in low-resource areas.
A methodology for hard/soft information fusion in the condition monitoring of aircraft
NASA Astrophysics Data System (ADS)
Bernardo, Joseph T.
2013-05-01
Condition-based maintenance (CBM) refers to the philosophy of performing maintenance when the need arises, based upon indicators of deterioration in the condition of the machinery. Traditionally, CBM involves equipping machinery with electronic sensors that continuously monitor components and collect data for analysis. The addition of the multisensory capability of human cognitive functions (i.e., sensemaking, problem detection, planning, adaptation, coordination, naturalistic decision making) to traditional CBM may create a fuller picture of machinery condition. Cognitive systems engineering techniques provide an opportunity to utilize a dynamic resource—people acting as soft sensors. The literature is extensive on techniques to fuse data from electronic sensors, but little work exists on fusing data from humans with that from electronic sensors (i.e., hard/soft fusion). The purpose of my research is to explore, observe, investigate, analyze, and evaluate the fusion of pilot and maintainer knowledge, experiences, and sensory perceptions with digital maintenance resources. Hard/soft information fusion has the potential to increase problem detection capability, improve flight safety, and increase mission readiness. This proposed project consists the creation of a methodology that is based upon the Living Laboratories framework, a research methodology that is built upon cognitive engineering principles1. This study performs a critical assessment of concept, which will support development of activities to demonstrate hard/soft information fusion in operationally relevant scenarios of aircraft maintenance. It consists of fieldwork, knowledge elicitation to inform a simulation and a prototype.
Lewis, Sheri L.; Feighner, Brian H.; Loschen, Wayne A.; Wojcik, Richard A.; Skora, Joseph F.; Coberly, Jacqueline S.; Blazes, David L.
2011-01-01
Public health surveillance is undergoing a revolution driven by advances in the field of information technology. Many countries have experienced vast improvements in the collection, ingestion, analysis, visualization, and dissemination of public health data. Resource-limited countries have lagged behind due to challenges in information technology infrastructure, public health resources, and the costs of proprietary software. The Suite for Automated Global Electronic bioSurveillance (SAGES) is a collection of modular, flexible, freely-available software tools for electronic disease surveillance in resource-limited settings. One or more SAGES tools may be used in concert with existing surveillance applications or the SAGES tools may be used en masse for an end-to-end biosurveillance capability. This flexibility allows for the development of an inexpensive, customized, and sustainable disease surveillance system. The ability to rapidly assess anomalous disease activity may lead to more efficient use of limited resources and better compliance with World Health Organization International Health Regulations. PMID:21572957
The Electron Microscopy Outreach Program: A Web-based resource for research and education.
Sosinsky, G E; Baker, T S; Hand, G; Ellisman, M H
1999-01-01
We have developed a centralized World Wide Web (WWW)-based environment that serves as a resource of software tools and expertise for biological electron microscopy. A major focus is molecular electron microscopy, but the site also includes information and links on structural biology at all levels of resolution. This site serves to help integrate or link structural biology techniques in accordance with user needs. The WWW site, called the Electron Microscopy (EM) Outreach Program (URL: http://emoutreach.sdsc.edu), provides scientists with computational and educational tools for their research and edification. In particular, we have set up a centralized resource containing course notes, references, and links to image analysis and three-dimensional reconstruction software for investigators wanting to learn about EM techniques either within or outside of their fields of expertise. Copyright 1999 Academic Press.
Detection of explosives, nerve agents, and illicit substances by zero-energy electron attachment
NASA Technical Reports Server (NTRS)
Chutjian, A.; Darrach, M. R.
2000-01-01
The Reversal Electron Attachment Detection (READ) method, developed at JPL/Caltech, has been used to detect a variety of substances which have electron-attachment resonances at low and intermediate electron energies. In the case of zero-energy resonances, the cross section (hence attachment probability and instrument sensitivity) is mediated by the so-called s-wave phenomenon, in which the cross sections vary as the inverse of the electron velocity. Hence this is, in the limit of zero electron energy or velocity, one of the rare cases in atomic and molecular physics where one carries out detection via infinite cross sections.
NASA Technical Reports Server (NTRS)
Mueller, Arnold W.; Smith, Charles D.
1991-01-01
NASA LaRC personnel have conducted a strudy of the predicted acoustic detection ranges associated with reduced helicopter main rotor speeds. This was accomplished by providing identical input information to both the aural detection program ICHIN 6, (I Can Hear It Now, version 6) and the electronic acoustic detection program ARCAS (Assessment of Rotorcraft Detection by Acoustics Sensing). In this study, it was concluded that reducing the main rotor speed of the helicopter by 27 percent reduced both the predicted aural and electronic detection ranges by approximately 50 percent. Additionally, ARCAS was observed to function better with narrowband spectral input than with one-third octave band spectral inputs and the predicted electronic range of acoustic detection is greater than the predicted aural detection range.
Quantitative secondary electron detection
DOE Office of Scientific and Technical Information (OSTI.GOV)
Agrawal, Jyoti; Joy, David C.; Nayak, Subuhadarshi
Quantitative Secondary Electron Detection (QSED) using the array of solid state devices (SSD) based electron-counters enable critical dimension metrology measurements in materials such as semiconductors, nanomaterials, and biological samples (FIG. 3). Methods and devices effect a quantitative detection of secondary electrons with the array of solid state detectors comprising a number of solid state detectors. An array senses the number of secondary electrons with a plurality of solid state detectors, counting the number of secondary electrons with a time to digital converter circuit in counter mode.
Acoustic enhancement for photo detecting devices
Thundat, Thomas G; Senesac, Lawrence R; Van Neste, Charles W
2013-02-19
Provided are improvements to photo detecting devices and methods for enhancing the sensitivity of photo detecting devices. A photo detecting device generates an electronic signal in response to a received light pulse. An electro-mechanical acoustic resonator, electrically coupled to the photo detecting device, damps the electronic signal and increases the signal noise ratio (SNR) of the electronic signal. Increased photo detector standoff distances and sensitivities will result.
ERIC Educational Resources Information Center
Abouelenein, Yousri
2017-01-01
This study aimed at investigating the factual situation of electronic information resources centers to faculty members at university education. Competencies that faculty members should possess regarding this issue were determined. Also their needs for (scientific research skills and teaching) were assessed. In addition, problems that hinder their…
18 CFR 154.4 - Electronic filing of tariffs and related materials.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 18 Conservation of Power and Water Resources 1 2010-04-01 2010-04-01 false Electronic filing of tariffs and related materials. 154.4 Section 154.4 Conservation of Power and Water Resources FEDERAL... the contents are true to the best knowledge and belief of the signer, and that the signer possesses...
Measures for Electronic Resources (E-Metrics). Complete Set.
ERIC Educational Resources Information Center
Association of Research Libraries, Washington, DC.
The Association of Research Libraries (ARL) E-Metrics study was designed as an 18-month project in three phases: an inventory of what libraries were already doing about data collection for electronic resources and an identification of any libraries that could provide best practice; identifying and testing data elements that could be collected and…
Redesign of Library Workflows: Experimental Models for Electronic Resource Description.
ERIC Educational Resources Information Center
Calhoun, Karen
This paper explores the potential for and progress of a gradual transition from a highly centralized model for cataloging to an iterative, collaborative, and broadly distributed model for electronic resource description. The purpose is to alert library managers to some experiments underway and to help them conceptualize new methods for defining,…
Technical Communicator: A New Model for the Electronic Resources Librarian?
ERIC Educational Resources Information Center
Hulseberg, Anna
2016-01-01
This article explores whether technical communicator is a useful model for electronic resources (ER) librarians. The fields of ER librarianship and technical communication (TC) originated and continue to develop in relation to evolving technologies. A review of the literature reveals four common themes for ER librarianship and TC. While the…
Managing Electronic Resources: A Survey of Current Practices in Academic Libraries.
ERIC Educational Resources Information Center
Shaw, Beth Hansen
This document reports results of an online survey that examined practices and procedures in the management of electronic resources in 65 academic library reference departments. Responses are related to: (1) student population; (2) library use by community people; (3) number of public access workstations, workstations with World Wide Web access,…
Telecommunications Handbook: Connecting to NEWTON. Version 1.4.
ERIC Educational Resources Information Center
Baker, Christopher; And Others
This handbook was written for use with the Argonne National Laboratory's electronic bulletin board system (BBS) called NEWTON, which is designed to create an electronic network that will link scientists, teachers, and students with the many diversified resources of the Argonne National Laboratory. The link to Argonne will include such resources as…
Selection and Presentation of Commercially Available Electronic Resources: Issues and Practices.
ERIC Educational Resources Information Center
Jewell, Timothy D.
This report focuses on practices related to the selection and presentation of commercially available electronic resources. As part of the Digital Library Federation's Collection Practices Initiative, the report also shares the goal of identifying and propagating practices that support the growth of sustainable and scalable collections. It looks in…
ERIC Educational Resources Information Center
Duy, Joanna; Vaughan, Liwen
2003-01-01
Vendor-provided electronic resource usage statistics are not currently standardized across vendors. This study investigates the feasibility of using locally collected data to check the reliability of vendor-provided data. Vendor-provided data were compared with local data collected from North Carolina State University (NCSU) Libraries' Web…
Hou, Juying; Dong, Jing; Zhu, Haishuang; Teng, Xue; Ai, Shiyun; Mang, Minglin
2015-06-15
In this paper, a simple and sensitive fluorescent sensor for methyl parathion is developed based on L-tyrosine methyl ester functionalized carbon dots (Tyr-CDs) and tyrosinase system. The carbon dots are obtained by simple hydrothermal reaction using citric acid as carbon resource and L-tyrosine methyl ester as modification reagent. The carbon dots are characterized by transmission electron microscope, high resolution transmission electron microscopy, X-ray diffraction spectrum, Fourier transform infrared spectroscopy, and X-ray photoelectron spectroscopy. The carbon dots show strong and stable photoluminescence with a quantum yield of 3.8%. Tyrosinase can catalyze the oxidation of tyrosine methyl ester on the surface of carbon dots to corresponding quinone products, which can quench the fluorescence of carbon dots. When organophosphorus pesticides (OPs) are introduced in system, they can decrease the enzyme activity, thus decrease the fluorescence quenching rate. Methyl parathion, as a model of OPs, was detected. Experimental results show that the enzyme inhibition rate is proportional to the logarithm of the methyl parathion concentration in the range 1.0×10(-10)-1.0×10(-4) M with the detection limit (S/N=3) of 4.8×10(-11) M. This determination method shows a low detection limit, wide linear range, good selectivity and high reproducibility. This sensing system has been successfully used for the analysis of cabbage, milk and fruit juice samples. Copyright © 2014 Elsevier B.V. All rights reserved.
Proportional counter device for detecting electronegative species in an air sample
Allman, Steve L.; Chen, Fang C.; Chen, Chung-Hsuan
1994-01-01
Apparatus for detecting an electronegative species comprises an analysis chamber, an inlet communicating with the analysis chamber for admitting a sample containing the electronegative species and an ionizable component, a radioactive source within the analysis chamber for emitting radioactive energy for ionizing a component of the sample, a proportional electron detector within the analysis chamber for detecting electrons emitted from the ionized component, and a circuit for measuring the electrons and determining the presence of the electronegative species by detecting a reduction in the number of available electrons due to capture of electrons by the electronegative species.
Proportional counter device for detecting electronegative species in an air sample
Allman, S.L.; Chen, F.C.; Chen, C.H.
1994-03-08
Apparatus for detecting an electronegative species comprises an analysis chamber, an inlet communicating with the analysis chamber for admitting a sample containing the electronegative species and an ionizable component, a radioactive source within the analysis chamber for emitting radioactive energy for ionizing a component of the sample, a proportional electron detector within the analysis chamber for detecting electrons emitted from the ionized component, and a circuit for measuring the electrons and determining the presence of the electronegative species by detecting a reduction in the number of available electrons due to capture of electrons by the electronegative species. 2 figures.
An overview of suite for automated global electronic biosurveillance (SAGES)
NASA Astrophysics Data System (ADS)
Lewis, Sheri L.; Feighner, Brian H.; Loschen, Wayne A.; Wojcik, Richard A.; Skora, Joseph F.; Coberly, Jacqueline S.; Blazes, David L.
2012-06-01
Public health surveillance is undergoing a revolution driven by advances in the field of information technology. Many countries have experienced vast improvements in the collection, ingestion, analysis, visualization, and dissemination of public health data. Resource-limited countries have lagged behind due to challenges in information technology infrastructure, public health resources, and the costs of proprietary software. The Suite for Automated Global Electronic bioSurveillance (SAGES) is a collection of modular, flexible, freely-available software tools for electronic disease surveillance in resource-limited settings. One or more SAGES tools may be used in concert with existing surveillance applications or the SAGES tools may be used en masse for an end-to-end biosurveillance capability. This flexibility allows for the development of an inexpensive, customized, and sustainable disease surveillance system. The ability to rapidly assess anomalous disease activity may lead to more efficient use of limited resources and better compliance with World Health Organization International Health Regulations.
Rafferty, Ryan S.
2013-01-01
Objectives: The research sought to determine if first-year medical students consulted and cited resources specifically highlighted during library instructional sessions. Methods: Students attended a library resources instructional session. Resources that pertained to the students' assignment were demonstrated and discussed. The students created a report including citations from relevant literature. The citations were analyzed and categorized as: a resource discussed at the instructional session, a resource found on the course LibGuide, a library resource, course material, or some other resource. All citations were subcategorized as print or electronic. Results: Three years (2008–2011) of data analyzing 2,983 citations showed that 49.55% of all citations were from resources discussed during library instructional sessions; 21.86% came from resources with links on the course LibGuide; 77.51% were from library resources; and 90.68% came from electronic resources. Conclusion: Students cited resources specifically highlighted during library instructional sessions for their assignments. The percentage of all citations coming from resources highlighted during the instructional sessions or found on the course LibGuide indicates that library instruction had an impact on the students' work. PMID:23930092
Detection of atomic force microscopy cantilever displacement with a transmitted electron beam
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wagner, R.; Woehl, T. J.; Keller, R. R.
2016-07-25
The response time of an atomic force microscopy (AFM) cantilever can be decreased by reducing cantilever size; however, the fastest AFM cantilevers are currently nearing the smallest size that can be detected with the conventional optical lever approach. Here, we demonstrate an electron beam detection scheme for measuring AFM cantilever oscillations. The oscillating AFM tip is positioned perpendicular to and in the path of a stationary focused nanometer sized electron beam. As the tip oscillates, the thickness of the material under the electron beam changes, causing a fluctuation in the number of scattered transmitted electrons that are detected. We demonstratemore » detection of sub-nanometer vibration amplitudes with an electron beam, providing a pathway for dynamic AFM with cantilevers that are orders of magnitude smaller and faster than the current state of the art.« less
Hart, James L; Lang, Andrew C; Leff, Asher C; Longo, Paolo; Trevor, Colin; Twesten, Ray D; Taheri, Mitra L
2017-08-15
In many cases, electron counting with direct detection sensors offers improved resolution, lower noise, and higher pixel density compared to conventional, indirect detection sensors for electron microscopy applications. Direct detection technology has previously been utilized, with great success, for imaging and diffraction, but potential advantages for spectroscopy remain unexplored. Here we compare the performance of a direct detection sensor operated in counting mode and an indirect detection sensor (scintillator/fiber-optic/CCD) for electron energy-loss spectroscopy. Clear improvements in measured detective quantum efficiency and combined energy resolution/energy field-of-view are offered by counting mode direct detection, showing promise for efficient spectrum imaging, low-dose mapping of beam-sensitive specimens, trace element analysis, and time-resolved spectroscopy. Despite the limited counting rate imposed by the readout electronics, we show that both core-loss and low-loss spectral acquisition are practical. These developments will benefit biologists, chemists, physicists, and materials scientists alike.
Low-dose electron energy-loss spectroscopy using electron counting direct detectors.
Maigné, Alan; Wolf, Matthias
2018-03-01
Since the development of parallel electron energy loss spectroscopy (EELS), charge-coupled devices (CCDs) have been the default detectors for EELS. With the recent development of electron-counting direct-detection cameras, micrographs can be acquired under very low electron doses at significantly improved signal-to-noise ratio. In spectroscopy, in particular in combination with a monochromator, the signal can be extremely weak and the detection limit is principally defined by noise introduced by the detector. Here we report the use of an electron-counting direct-detection camera for EEL spectroscopy. We studied the oxygen K edge of amorphous ice and obtained a signal noise ratio up to 10 times higher than with a conventional CCD.We report the application of electron counting to record time-resolved EEL spectra of a biological protein embedded in amorphous ice, revealing chemical changes observed in situ while exposed by the electron beam. A change in the fine structure of nitrogen K and the carbon K edges were recorded during irradiation. A concentration of 3 at% nitrogen was detected with a total electron dose of only 1.7 e-/Å2, extending the boundaries of EELS signal detection at low electron doses.
The "EyeCane", a new electronic travel aid for the blind: Technology, behavior & swift learning.
Maidenbaum, Shachar; Hanassy, Shlomi; Abboud, Sami; Buchs, Galit; Chebat, Daniel-Robert; Levy-Tzedek, Shelly; Amedi, Amir
2014-01-01
Independent mobility is one of the most pressing problems facing people who are blind. We present the EyeCane, a new mobility aid aimed at increasing perception of environment beyond what is provided by the traditional White Cane for tasks such as distance estimation, navigation and obstacle detection. The "EyeCane" enhances the traditional White Cane by using tactile and auditory output to increase detectable distance and angles. It circumvents the technical pitfalls of other devices, such as weight, short battery life, complex interface schemes, and slow learning curve. It implements multiple beams to enables detection of obstacles at different heights, and narrow beams to provide active sensing that can potentially increase the user's spatial perception of the environment. Participants were tasked with using the EyeCane for several basic tasks with minimal training. Blind and blindfolded-sighted participants were able to use the EyeCane successfully for distance estimation, simple navigation and simple obstacle detection after only several minutes of training. These results demonstrate the EyeCane's potential for mobility rehabilitation. The short training time is especially important since available mobility training resources are limited, not always available, and can be quite expensive and/or entail long waiting periods.
18 CFR 35.7 - Electronic filing requirements.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 18 Conservation of Power and Water Resources 1 2011-04-01 2011-04-01 false Electronic filing... § 35.7 Electronic filing requirements. (a) General rule. All filings made in proceedings initiated... declarations or statements and electronic signatures. (c) Format requirements for electronic filing. The...
18 CFR 35.7 - Electronic filing requirements.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 18 Conservation of Power and Water Resources 1 2012-04-01 2012-04-01 false Electronic filing... § 35.7 Electronic filing requirements. (a) General rule. All filings made in proceedings initiated... declarations or statements and electronic signatures. (c) Format requirements for electronic filing. The...
18 CFR 35.7 - Electronic filing requirements.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 18 Conservation of Power and Water Resources 1 2013-04-01 2013-04-01 false Electronic filing... § 35.7 Electronic filing requirements. (a) General rule. All filings made in proceedings initiated... declarations or statements and electronic signatures. (c) Format requirements for electronic filing. The...
18 CFR 35.7 - Electronic filing requirements.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 18 Conservation of Power and Water Resources 1 2014-04-01 2014-04-01 false Electronic filing... § 35.7 Electronic filing requirements. (a) General rule. All filings made in proceedings initiated... declarations or statements and electronic signatures. (c) Format requirements for electronic filing. The...
Hendrix, Dean; Hasman, Linda
2008-07-01
The research sought to ascertain medical and dental libraries' collection development policies, evaluation methods, purchase decisions, and issues that relate to print and electronic United States Medical Licensing Examination (USMLE) and National Board Dental Examination (NBDE) preparation materials. The investigators surveyed librarians supporting American Association of Medical Colleges (AAMC)-accredited medical schools (n = 58/125) on the USMLE and librarians supporting American Dental Association (ADA)-accredited dental schools (n = 23/56) on the NBDE. The investigators analyzed the data by cross-tabulating and filtering the results using EFM Continuum web survey software. Investigators also surveyed print and electronic USMLE and NBDE preparation materials from 2004-2007 to determine the number of publications and existence of reviews. A majority of responding AAMC libraries (62%, n = 58) provide at least 1 electronic or online USMLE preparation resource and buy an average of 11.6 print USMLE titles annually. Due to a paucity of NBDE print and electronic resources, ADA libraries bought significantly fewer print resources, and only 1 subscribed to an electronic resource. The most often reported evaluation methods for both populations were feedback from medical or dental students, feedback from medical or dental faculty, and online trials. Some AAMC (10%, n = 58) and ADA libraries (39%, n = 23) libraries reported that no evaluation of these materials occured at their libraries. From 2004-2007, publishers produced 45 USMLE preparation resources (total n = 546) to every 1 NBDE preparation resource (total n = 12). Users' needs, institutional missions and goals, financial status, and official collection policies most often underlie decisions to collect or not collect examination preparation materials. Evaluating the quality of examination preparation materials can be problematic due to lack of published reviews, lack of usability testing by libraries, and librarians' and library users' unfamiliarity with the actual content of examinations. Libraries must integrate faculty and students into the purchase process to make sure examination preparation resources of the highest quality are purchased.
ERIC Educational Resources Information Center
Emery, Erin E.; Lapidos, Stan; Eisenstein, Amy R.; Ivan, Iulia I.; Golden, Robyn L.
2012-01-01
Purpose: To demonstrate the feasibility of the BRIGHTEN Program (Bridging Resources of an Interdisciplinary Geriatric Health Team via Electronic Networking), an interdisciplinary team intervention for assessing and treating older adults for depression in outpatient primary and specialty medical clinics. The BRIGHTEN team collaborates "virtually"…
A Survey of the Use of Electronic Resources at Seven Universities in Wuhan, China
ERIC Educational Resources Information Center
Zhang, Liyi; Ye, Pinghao; Liu, Qihua
2011-01-01
Purpose: The purpose of this paper is to report on users' information behaviour in China, a topic which has not been researched extensively. The aim is to help producers and providers collect and develop more electronic resources. Design/methodology/approach: The study investigates users' information behaviour at seven "211 Project"…
18 CFR 341.1 - Electronic filing of tariffs and related materials.
Code of Federal Regulations, 2010 CFR
2010-04-01
... contents are true to the best knowledge and belief of the signer, and that the signer possesses full power... 18 Conservation of Power and Water Resources 1 2010-04-01 2010-04-01 false Electronic filing of tariffs and related materials. 341.1 Section 341.1 Conservation of Power and Water Resources FEDERAL...
NASA Astrophysics Data System (ADS)
Solnyshkova, Olga; Makarikhina, Inna
2017-10-01
Prerequisites for students’ professional communication elements forming on the base of civil engineering universities are investigated in the article. Students’ professional communication elements must be used in their future professional activities. The workshop creative experience of interactive electronic educational resources development during the study possesses of geodetic disciplines on the basis of University of Architecture and Civil Engineering (Siberia) is described. The stages of students’ processional communication formation in the process of interactive electronic educational resources creation by students and teachers are proposed. The offers to increase the efficiency of professional communication elements formation for students in the development of interactive electronic educational resources within the student creative workshop were made.
Direct Detection and Imaging of Low-Energy Electrons with Delta-Doped Charge-Coupled Devices
NASA Technical Reports Server (NTRS)
Nikzad, S.; Yu, Q.; Smith, A. L.; Jones, T. J.; Tombrello, T. A.; Elliott, S. T.
1998-01-01
We report the use fo delta-doped charge-coupled devices (CCDs) for direct detection of electrons in the 50-1500 eV energy range. These are the first measurements with a solid state device to detect electrons in this energy range.
Lu, Qiujun; Chen, Xiaogen; Liu, Dan; Wu, Cuiyan; Liu, Meiling; Li, Haitao; Zhang, Youyu; Yao, Shouzhuo
2018-05-15
The selective and sensitive detection of dopamine (DA) is of great significance for the identification of schizophrenia, Huntington's disease, and Parkinson's disease from the perspective of molecular diagnostics. So far, most of DA fluorescence sensors are based on the electron transfer from the fluorescence nanomaterials to DA-quinone. However, the limited electron transfer ability of the DA-quinone affects the level of detection sensitivity of these sensors. In this work, based on the DA can reduce Ag + into AgNPs followed by oxidized to DA-quinone, we developed a novel silicon nanoparticles-based electron transfer fluorescent sensor for the detection of DA. As electron transfer acceptor, the AgNPs and DA-quinone can quench the fluorescence of silicon nanoparticles effectively through the synergistic electron transfer effect. Compared with traditional fluorescence DA sensors, the proposed synergistic electron transfer-based sensor improves the detection sensitivity to a great extent (at least 10-fold improvement). The proposed sensor shows a low detection limit of DA, which is as low as 0.1 nM under the optimal conditions. This sensor has potential applicability for the detection of DA in practical sample. This work has been demonstrated to contribute to a substantial improvement in the sensitivity of the sensors. It also gives new insight into design electron transfer-based sensors. Copyright © 2018. Published by Elsevier B.V.
RTDS-Based Design and Simulation of Distributed P-Q Power Resources in Smart Grid
NASA Astrophysics Data System (ADS)
Taylor, Zachariah David
In this Thesis, we propose to utilize a battery system together with its power electronics interfaces and bidirectional charger as a distributed P-Q resource in power distribution networks. First, we present an optimization-based approach to operate such distributed P-Q resources based on the characteristics of the battery and charger system as well as the features and needs of the power distribution network. Then, we use the RTDS Simulator, which is an industry-standard simulation tool of power systems, to develop two RTDS-based design approaches. The first design is based on an ideal four-quadrant distributed P-Q power resource. The second design is based on a detailed four-quadrant distributed P-Q power resource that is developed using power electronics components. The hardware and power electronics circuitry as well as the control units are explained for the second design. After that, given the two-RTDS designs, we conducted extensive RTDS simulations to assess the performance of the designed distributed P-Q Power Resource in an IEEE 13 bus test system. We observed that the proposed design can noticeably improve the operational performance of the power distribution grid in at least four key aspects: reducing power loss, active power peak load shaving at substation, reactive power peak load shaving at substation, and voltage regulation. We examine these performance measures across three design cases: Case 1: There is no P-Q Power Resource available on the power distribution network. Case 2: The installed P-Q Power Resource only supports active power, i.e., it only utilizes its battery component. Case 3: The installed P-Q Power Resource supports both active and reactive power, i.e., it utilizes both its battery component and its power electronics charger component. In the end, we present insightful interpretations on the simulation results and suggest some future works.
The Resource Prospector Neutron Spectrometer System: RP's Bloodhound
NASA Technical Reports Server (NTRS)
Elphic, Richard C.; Fritzler, E.; Mobilia, J.; Kou, A.
2017-01-01
The primary goal of the Resource Prospector Neutron Spectrometer System (NSS) is to locate and characterize hydrogen-bearing volatile deposits, especially subsurface ice, that may exist at the lunar poles. A key objective is to detect water-equivalent hydrogen concentrations of 0.5 wt% or greater while on a moving rover. A second objective is to determine approximate burial depth of enhanced hydrogen-bearing materials up to 1 meter below otherwise dry regolith. The instrument will be carried aboard a landed mobility system at the lunar poles. The instrument operates by measuring the changes in the leakage flux of low energy neutrons out of the regolith. These neutrons are produced by galactic cosmic rays, which are so energetic that they shatter the nuclei in surface materials. The neutrons interact with other nuclei and lose energy, becoming thermalized in the process. Hydrogen is most efficient at thermalizing neutrons owing to protons' similar mass - statistically, neutrons lose half their energy per collision with protons. With hydrogen in the soil, leakage fluxes of neutrons in the 0.5 eV to 500 keV energy range are reduced. A concentration of only1-2 wt% water-equivalent hydrogen results in a decrease in epithermal leakage flux of a factor of two. The leakage flux of thermal neutrons, from 0 to 0.5 eV in energy, can either increase or decrease depending on the hydrogen abundance and stratigraphy. As with the highly successful Lunar Prospector Neutron Spectrometer, the RP NSS detects both thermal and epithermal neutrons by using two helium-3 gas proportional counters, one covered by cadmium and the other uncovered. The former detects only epithermal neutrons with energies above approximately 0.5 eV, the latter detects both thermal (less than 0.5 eV) and epithermal energies (greater than 0.5 eV). When a neutron enters the detector tube and interacts with a helium-3 nucleus, the resulting reaction produces an energetic proton and triton that ionize the gas. The resulting electrons are accelerated toward a high-voltage anode and cascade, amplifying the net charge, which is collected at the anode. The number of electrons produced is proportional to the energy that the triton and proton deposit in the gas. A charge sensitive pre-amplifier converts the total charge to a step voltage output. A shaper amplifier then shapes this step into a uni-polar waveform with peaking time appropriate for the detection depending on the event rate. The integrated shaped waveform, representing the deposited triton/proton energy, is then measured. A histogram, or pulse height analysis, is performed to record the main capture peak and wall effect pulses. A threshold for detection is also required to limit the low amplitude counting rate such as noise floor. The system electronics consists of 2 modules - the Sensor Module (SM) front-end and the Data Processing Module (DPM) back-end circuits. SM is designed as a light-weight and low power front-end housing the two helium-3 proportional counter detectors, preamp and HVPS. It is mounted external to the rover body to detect the thermalized neutron flux with a minimum of host background. The DPM is located inside the rover; it digitizes the SM signals, performs pulse height analysis and accumulates the count rate for each spectral channel. The DPM controls high voltage and thresholding, and sends the science data to the host craft via an RS422 serial asynchronous protocol. The payload host provides all thermal management and control for the SM and DPM.
NASA Astrophysics Data System (ADS)
Johnson, D.; Ruzek, M.; Weatherley, J.
2001-05-01
The Journal of Earth System Science Education is a new interdisciplinary electronic journal aiming to foster the study of the Earth as a system and promote the development and exchange of interdisciplinary learning resources for formal and informal education. JESSE will serve educators and students by publishing and providing ready electronic access to Earth system and global change science learning resources for the classroom and will provide authors and creators with professional recognition through publication in a peer reviewed journal. JESSE resources foster a world perspective by emphasizing interdisciplinary studies and bridging disciplines in the context of the Earth system. The Journal will publish a wide ranging variety of electronic content, with minimal constraints on format, targeting undergraduate educators and students as the principal readership, expanding to a middle and high school audience as the journal matures. JESSE aims for rapid review and turn-around of resources to be published, with a goal of 12 weeks from submission to publication for resources requiring few changes. Initial publication will be on a quarterly basis until a flow of resource submissions is established to warrant continuous electronic publication. JESSE employs an open peer review process in which authors and reviewers discuss directly the acceptability of a resource for publication using a software tool called the Digital Document Discourse Environment. Reviewer comments and attribution will be available with the resource upon acceptance for publication. JESSE will also implement a moderated peer commentary capability where readers can comment on the use of a resource or make suggestions. In the development phase, JESSE will also conduct a parallel anonymous review of content to validate and ensure credibility of the open review approach. Copyright of materials submitted remains with the author, granting JESSE the non-exclusive right to maintain a copy of the resource published on the JESSE web server, ensuring long term access to the resource as reviewed. JESSE is collaborating with the Digital Library for Earth System Education (DLESE) as a federated partner. Initial release is planned for Summer, 2001.
Compact low-cost detection electronics for optical coherence imaging
Akcay, A. C.; Lee, K. S.; Furenlid, L. R.; Costa, M. A.; Rolland, J. P.
2015-01-01
A compact and low-cost detection electronics scheme for optical coherence imaging is demonstrated. The performance of the designed electronics is analyzed in comparison to a commercial lock-in amplifier of equal bandwidth. Images of a fresh-onion sample are presented for each detection configuration. PMID:26617422
Electronic Journals in Academic Libraries: A Comparison of ARL and Non-ARL Libraries.
ERIC Educational Resources Information Center
Shemberg, Marian; Grossman, Cheryl
1999-01-01
Describes a survey dealing with academic library provision of electronic journals and other electronic resources that compared ARL (Association of Research Libraries) members to non-ARL members. Highlights include full-text electronic journals; computers in libraries; online public access catalogs; interlibrary loan and electronic reserves; access…
ALA Guide to Medical & Health Sciences Reference
ERIC Educational Resources Information Center
ALA Editions, 2011
2011-01-01
This resource provides an annotated list of print and electronic biomedical and health-related reference sources, including Internet resources and digital image collections. Readers will find relevant research, clinical, and consumer health information resources. The emphasis is on resources within the United States, with a few representative…
Potential resource and toxicity impacts from metals in waste electronic devices.
Woo, Seung H; Lee, Dae Sung; Lim, Seong-Rin
2016-04-01
As a result of the continuous release of new electronic devices, existing electronic devices are quickly made obsolete and rapidly become electronic waste (e-waste). Because e-waste contains a variety of metals, information about those metals with the potential for substantial environmental impact should be provided to manufacturers, recyclers, and disposers to proactively reduce this impact. This study assesses the resource and toxicity (i.e., cancer, noncancer, and ecotoxicity) potentials of various heavy metals commonly found in e-waste from laptop computers, liquid-crystal display (LCD) monitors, LCD TVs, plasma TVs, color cathode ray tube (CRT) TVs, and cell phones and then evaluates such potentials using life cycle impact-based methods. Resource potentials derive primarily from Cu, Sb, Ag, and Pb. Toxicity potentials derive primarily from Pb, Ni, and Hg for cancer toxicity; from Pb, Hg, Zn, and As for noncancer toxicity; and from Cu, Pb, Hg, and Zn for ecotoxicity. Therefore, managing these heavy metals should be a high priority in the design, recycling, and disposal stages of electronic devices. © 2015 SETAC.
Stiltner, G.J.
1990-01-01
In 1987, the Water Resources Division of the U.S. Geological Survey undertook three pilot projects to evaluate electronic report processing systems as a means to improve the quality and timeliness of reports pertaining to water resources investigations. The three projects selected for study included the use of the following configuration of software and hardware: Ventura Publisher software on an IBM model AT personal computer, PageMaker software on a Macintosh computer, and FrameMaker software on a Sun Microsystems workstation. The following assessment criteria were to be addressed in the pilot studies: The combined use of text, tables, and graphics; analysis of time; ease of learning; compatibility with the existing minicomputer system; and technical limitations. It was considered essential that the camera-ready copy produced be in a format suitable for publication. Visual improvement alone was not a consideration. This report consolidates and summarizes the findings of the electronic report processing pilot projects. Text and table files originating on the existing minicomputer system were successfully transformed to the electronic report processing systems in American Standard Code for Information Interchange (ASCII) format. Graphics prepared using a proprietary graphics software package were transferred to all the electronic report processing software through the use of Computer Graphic Metafiles. Graphics from other sources were entered into the systems by scanning paper images. Comparative analysis of time needed to process text and tables by the electronic report processing systems and by conventional methods indicated that, although more time is invested in creating the original page composition for an electronically processed report , substantial time is saved in producing subsequent reports because the format can be stored and re-used by electronic means as a template. Because of the more compact page layouts, costs of printing the reports were 15% to 25% less than costs of printing the reports prepared by conventional methods. Because the largest report workload in the offices conducting water resources investigations is preparation of Water-Resources Investigations Reports, Open-File Reports, and annual State Data Reports, the pilot studies only involved these projects. (USGS)
ERIC Educational Resources Information Center
Hartnett, Eric; Beh, Eugenia; Resnick, Taryn; Ugaz, Ana; Tabacaru, Simona
2013-01-01
In 2010, after two previous unsuccessful attempts at electronic resources management system (ERMS) implementation, Texas A&M University (TAMU) Libraries set out once again to find an ERMS that would fit its needs. After surveying the field, TAMU Libraries selected the University of Notre Dame Hesburgh Libraries-developed, open-source ERMS,…
ERIC Educational Resources Information Center
Akussah, Maxwell; Asante, Edward; Adu-Sarkodee, Rosemary
2015-01-01
The study investigates the relationship between impact of electronic resources and its usage in academic libraries in Ghana: evidence from Koforidua Polytechnic & All Nations University College, Ghana. The study was a quantitative approach using questionnaire to gather data and information. A valid response rate of 58.5% was assumed. SPSS…
ERIC Educational Resources Information Center
Amjad, Anam; Ahmed, Shamshad; Bin Naeem, Salman
2013-01-01
This study examined the use of electronic resources among academic scholars of The Islamia University of Bahawalpur (IUB), Punjab, Pakistan. A quantitative survey was found most convenient and useful for this study. The total population of the study was 169 research students in IUB. The response rate was 79% and 133 utilizable responses were coded…
Electronic Collection Development: A Practical Guide.
ERIC Educational Resources Information Center
Lee, Stuart D.
Chapter 1, "Preliminary Issues," explores the historical importance of the electronic publishing revolution, some of the terminology to be used in the book, and the differences and similarities between traditional and electronic collection development. Chapter 2, "What Is an Offer? The Electronic Resources Landscape," covers…
Explore a Career in Health Sciences Information
... tools that range from traditional print journals to electronic databases and the latest mobile devices, health sciences ... an expert search of the literature. connecting licensed electronic resources and decision tools into a patient's electronic ...
NASA Technical Reports Server (NTRS)
Gershman, Daniel J.; Gliese, Ulrik; Dorelli, John C.; Avanov, Levon A.; Barrie, Alexander C.; Chornay, Dennis J.; MacDonald, Elizabeth A.; Holland, Matthew P.; Pollock, Craig J.
2015-01-01
The most common instrument for low energy plasmas consists of a top-hat electrostatic analyzer geometry coupled with a microchannel-plate (MCP)-based detection system. While the electrostatic optics for such sensors are readily simulated and parameterized during the laboratory calibration process, the detection system is often less well characterized. Furthermore, due to finite resources, for large sensor suites such as the Fast Plasma Investigation (FPI) on NASA's Magnetospheric Multiscale (MMS) mission, calibration data are increasingly sparse. Measurements must be interpolated and extrapolated to understand instrument behavior for untestable operating modes and yet sensor inter-calibration is critical to mission success. To characterize instruments from a minimal set of parameters we have developed the first comprehensive mathematical description of both sensor electrostatic optics and particle detection systems. We include effects of MCP efficiency, gain, scattering, capacitive crosstalk, and charge cloud spreading at the detector output. Our parameterization enables the interpolation and extrapolation of instrument response to all relevant particle energies, detector high voltage settings, and polar angles from a small set of calibration data. We apply this model to the 32 sensor heads in the Dual Electron Sensor (DES) and 32 sensor heads in the Dual Ion Sensor (DIS) instruments on the 4 MMS observatories and use least squares fitting of calibration data to extract all key instrument parameters. Parameters that will evolve in flight, namely MCP gain, will be determined daily through application of this model to specifically tailored in-flight calibration activities, providing a robust characterization of sensor suite performance throughout mission lifetime. Beyond FPI, our model provides a valuable framework for the simulation and evaluation of future detection system designs and can be used to maximize instrument understanding with minimal calibration resources.
Ricci, Renato Pietro; Morichelli, Loredana; D'Onofrio, Antonio; Calò, Leonardo; Vaccari, Diego; Zanotto, Gabriele; Curnis, Antonio; Buja, Gianfranco; Rovai, Nicola; Gargaro, Alessio
2013-01-01
Aims The HomeGuide Registry was a prospective study (NCT01459874), implementing a model for remote monitoring of cardiac implantable electronic devices (CIEDs) in daily clinical practice, to estimate effectiveness in major cardiovascular event detection and management. Methods and results The workflow for remote monitoring [Biotronik Home Monitoring (HM)] was based on primary nursing: each patient was assigned to an expert nurse for management and to a responsible physician for medical decisions. In-person visits were scheduled once a year. Seventy-five Italian sites enrolled 1650 patients [27% pacemakers, 27% single-chamber implantable cardioverter defibrillators (ICDs), 22% dual-chamber ICDs, 24% ICDs with cardiac resynchronization therapy]. Population resembled the expected characteristics of CIED patients. During a 20 ± 13 month follow-up, 2471 independently adjudicated events were collected in 838 patients (51%): 2033 (82%) were detected during HM sessions; 438 (18%) during in-person visits. Sixty were classified as false-positive, with generalized estimating equation-adjusted sensitivity and positive predictive value of 84.3% [confidence interval (CI), 82.5–86.0%] and 97.4% (CI, 96.5–98.2%), respectively. Overall, 95% of asymptomatic and 73% of actionable events were detected during HM sessions. Median reaction time was 3 days [interquartile range (IQR), 1–14 days]. Generalized estimating equation-adjusted incremental utility, calculated according to four properties of major clinical interest, was in favour of the HM sessions: +0.56 (CI, 0.53–0.58%), P < 0.0001. Resource consumption: 3364 HM sessions performed (76% by nurses), median committed monthly manpower of 55.5 (IQR, 22.0–107.0) min × health personnel/100 patients. Conclusion Home Monitoring was highly effective in detecting and managing clinical events in CIED patients in daily practice with remarkably low manpower and resource consumption. PMID:23362021
Tools, Techniques, and Training: Results of an E-Resources Troubleshooting Survey
ERIC Educational Resources Information Center
Rathmel, Angela; Mobley, Liisa; Pennington, Buddy; Chandler, Adam
2015-01-01
A primary role of any e-resources librarian or staff is troubleshooting electronic resources (e-resources). While much progress has been made in many areas of e-resources management (ERM) to understand the ERM lifecycle and to manage workflows, troubleshooting access remains a challenge. This collaborative study is the result of the well-received…
ERIC Educational Resources Information Center
Sriram, B.
2016-01-01
The internet resources are one of the important knowledge sharing tools in day-to-day business processes. These internet resources have greater impact on education field too. The learning processes have become comparatively easy due to these electronic resources. The online resources help the students to acquire the required knowledge through…
Lee, Stephen; Aranyosi, A J; Wong, Michelle D; Hong, Ji Hyung; Lowe, Jared; Chan, Carol; Garlock, David; Shaw, Scott; Beattie, Patrick D; Kratochvil, Zachary; Kubasti, Nick; Seagers, Kirsten; Ghaffari, Roozbeh; Swanson, Christina D
2016-04-15
In developing countries, the deployment of medical diagnostic technologies remains a challenge because of infrastructural limitations (e.g. refrigeration, electricity), and paucity of health professionals, distribution centers and transportation systems. Here we demonstrate the technical development and clinical testing of a novel electronics enabled microfluidic paper-based analytical device (EE-μPAD) for quantitative measurement of micronutrient concentrations in decentralized, resource-limited settings. The system performs immune-detection using paper-based microfluidics, instrumented with flexible electronics and optoelectronic sensors in a mechanically robust, ultrathin format comparable in size to a credit card. Autonomous self-calibration, plasma separation, flow monitoring, timing and data storage enable multiple devices to be run simultaneously. Measurements are wirelessly transferred to a mobile phone application that geo-tags the data and transmits it to a remote server for real time tracking of micronutrient deficiencies. Clinical tests of micronutrient levels from whole blood samples (n=95) show comparable sensitivity and specificity to ELISA-based tests. These results demonstrate instantaneous acquisition and global aggregation of diagnostics data using a fully integrated point of care system that will enable rapid and distributed surveillance of disease prevalence and geographical progression. Copyright © 2015 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Zeng, Qingtian; Liu, Cong; Duan, Hua
2016-09-01
Correctness of an emergency response process specification is critical to emergency mission success. Therefore, errors in the specification should be detected and corrected at build-time. In this paper, we propose a resource conflict detection approach and removal strategy for emergency response processes constrained by resources and time. In this kind of emergency response process, there are two timing functions representing the minimum and maximum execution time for each activity, respectively, and many activities require resources to be executed. Based on the RT_ERP_Net, the earliest time to start each activity and the ideal execution time of the process can be obtained. To detect and remove the resource conflicts in the process, the conflict detection algorithms and a priority-activity-first resolution strategy are given. In this way, real execution time for each activity is obtained and a conflict-free RT_ERP_Net is constructed by adding virtual activities. By experiments, it is proved that the resolution strategy proposed can shorten the execution time of the whole process to a great degree.
Use of Web-based library resources by medical students in community and ambulatory settings.
Tannery, Nancy Hrinya; Foust, Jill E; Gregg, Amy L; Hartman, Linda M; Kuller, Alice B; Worona, Paul; Tulsky, Asher A
2002-07-01
The purpose was to evaluate the use of Web-based library resources by third-year medical students. Third-year medical students (147) in a twelve-week multidisciplinary primary care rotation in community and ambulatory settings. Individual user surveys and log file analysis of Website were used. Twenty resource topics were compiled into a Website to provide students with access to electronic library resources from any community-based clerkship location. These resource topics, covering subjects such as hypertension and back pain, linked to curriculum training problems, full-text journal articles, MEDLINE searches, electronic book chapters, and relevant Websites. More than half of the students (69%) accessed the Website on a daily or weekly basis. Over 80% thought the Website was a valuable addition to their clerkship. Web-based information resources can provide curriculum support to students for whom access to the library is difficult and time consuming.
Hale, LaDonna S; Wallace, Michelle M; Adams, Courtney R; Kaufman, Michelle L; Snyder, Courtney L
2015-09-01
Selecting resources to support didactic courses is a critical decision, and the advantages and disadvantages must be carefully considered. During clinical rotations, students not only need to possess strong background knowledge but also are expected to be proficient with the same evidence-based POC resources used by clinicians. Students place high value on “real world” learning and therefore may place more value on POC resources that they know practicing clinicians use as compared with medical textbooks. The condensed nature of PA education requires students to develop background knowledge and information literacy skills over a short period. One way to build that knowledge and those skills simultaneously is to use POC resources in lieu of traditional medical textbooks during didactic training. Electronic POC resources offer several advantages over traditional textbooks and should be considered as viable options in PA education.
Murphy, Andrea L; Fleming, Mark; Martin-Misener, Ruth; Sketris, Ingrid S; MacCara, Mary; Gass, David
2006-01-01
Background Keeping current with drug therapy information is challenging for health care practitioners. Technologies are often implemented to facilitate access to current and credible drug information sources. In the Canadian province of Nova Scotia, legislation was passed in 2002 to allow nurse practitioners (NPs) to practice collaboratively with physician partners. The purpose of this study was to determine the current utilization patterns of information technologies by these groups of practitioners. Methods Nurse practitioners and their collaborating physician partners in Nova Scotia were sent a survey in February 2005 to determine the frequency of use, usefulness, accessibility, credibility, and current/timeliness of personal digital assistant (PDA), computer, and print drug information resources. Two surveys were developed (one for PDA users and one for computer users) and revised based on a literature search, stakeholder consultation, and pilot-testing results. A second distribution to nonresponders occurred two weeks following the first. Data were entered and analysed with SPSS. Results Twenty-seven (14 NPs and 13 physicians) of 36 (75%) recipients responded. 22% (6) returned personal digital assistant (PDA) surveys. Respondents reported print, health professionals, and online/electronic resources as the most to least preferred means to access drug information, respectively. 37% and 35% of respondents reported using "both print and electronic but print more than electronic" and "print only", respectively, to search monograph-related drug information queries whereas 4% reported using "PDA only". Analysis of respondent ratings for all resources in the categories print, health professionals and other, and online/electronic resources, indicated that the Compendium of Pharmaceuticals and Specialties and pharmacists ranked highly for frequency of use, usefulness, accessibility, credibility, and current/timeliness by both groups of practitioners. Respondents' preferences and resource ratings were consistent with self-reported methods for conducting drug information queries. Few differences existed between NP and physician rankings of resources. Conclusion The use of computers and PDAs remains limited, which is also consistent with preferred and frequent use of print resources. Education for these practitioners regarding available electronic drug information resources may facilitate future computer and PDA use. Further research is needed to determine methods to increase computer and PDA use and whether these technologies affect prescribing and patient outcomes. PMID:16822323
The Use of Electronic Book Theft Detection Systems in Libraries.
ERIC Educational Resources Information Center
Witt, Thomas B.
1996-01-01
Although electronic book theft detection systems can be a deterrent to library material theft, no electronic system is foolproof, and a total security program is necessary to ensure collection security. Describes how book theft detection systems work, their effectiveness, and the problems inherent in technology. A total security program considers…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chida, K.; Yamauchi, Y.; Arakawa, T.
2013-12-04
We performed the resistively-detected nuclear magnetic resonance (RDNMR) to study the electron spin polarization in the non-equilibrium quantum Hall regime. By measuring the Knight shift, we derive source-drain bias voltage dependence of the electron spin polarization in quantum wires. The electron spin polarization shows minimum value around the threshold voltage of the dynamic nuclear polarization.
Use of Web-based library resources by medical students in community and ambulatory settings*
Tannery, Nancy Hrinya; Foust, Jill E.; Gregg, Amy L.; Hartman, Linda M.; Kuller, Alice B.; Worona, Paul; Tulsky, Asher A.
2002-01-01
Purpose: The purpose was to evaluate the use of Web-based library resources by third-year medical students. Setting/Participants/Resources: Third-year medical students (147) in a twelve-week multidisciplinary primary care rotation in community and ambulatory settings. Methodology: Individual user surveys and log file analysis of Website were used. Results/Outcomes: Twenty resource topics were compiled into a Website to provide students with access to electronic library resources from any community-based clerkship location. These resource topics, covering subjects such as hypertension and back pain, linked to curriculum training problems, full-text journal articles, MEDLINE searches, electronic book chapters, and relevant Websites. More than half of the students (69%) accessed the Website on a daily or weekly basis. Over 80% thought the Website was a valuable addition to their clerkship. Discussion/Conclusion: Web-based information resources can provide curriculum support to students for whom access to the library is difficult and time consuming. PMID:12113515
People counting in classroom based on video surveillance
NASA Astrophysics Data System (ADS)
Zhang, Quanbin; Huang, Xiang; Su, Juan
2014-11-01
Currently, the switches of the lights and other electronic devices in the classroom are mainly relied on manual control, as a result, many lights are on while no one or only few people in the classroom. It is important to change the current situation and control the electronic devices intelligently according to the number and the distribution of the students in the classroom, so as to reduce the considerable waste of electronic resources. This paper studies the problem of people counting in classroom based on video surveillance. As the camera in the classroom can not get the full shape contour information of bodies and the clear features information of faces, most of the classical algorithms such as the pedestrian detection method based on HOG (histograms of oriented gradient) feature and the face detection method based on machine learning are unable to obtain a satisfied result. A new kind of dual background updating model based on sparse and low-rank matrix decomposition is proposed in this paper, according to the fact that most of the students in the classroom are almost in stationary state and there are body movement occasionally. Firstly, combining the frame difference with the sparse and low-rank matrix decomposition to predict the moving areas, and updating the background model with different parameters according to the positional relationship between the pixels of current video frame and the predicted motion regions. Secondly, the regions of moving objects are determined based on the updated background using the background subtraction method. Finally, some operations including binarization, median filtering and morphology processing, connected component detection, etc. are performed on the regions acquired by the background subtraction, in order to induce the effects of the noise and obtain the number of people in the classroom. The experiment results show the validity of the algorithm of people counting.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Warkentin, H; Bubric, K; Giovannetti, H
2016-06-15
Purpose: As a quality improvement measure, we undertook this work to incorporate usability testing into the implementation procedures for new electronic documents and forms used by four affiliated radiation therapy centers. Methods: A human factors specialist provided training in usability testing for a team of medical physicists, radiation therapists, and radiation oncologists from four radiotherapy centers. A usability testing plan was then developed that included controlled scenarios and standardized forms for qualitative and quantitative feedback from participants, including patients. Usability tests were performed by end users using the same hardware and viewing conditions that are found in the clinical environment.more » A pilot test of a form used during radiotherapy CT simulation was performed in a single department; feedback informed adaptive improvements to the electronic form, hardware requirements, resource accessibility and the usability testing plan. Following refinements to the testing plan, usability testing was performed at three affiliated cancer centers with different vault layouts and hardware. Results: Feedback from the testing resulted in the detection of 6 critical errors (omissions and inability to complete task without assistance), 6 non-critical errors (recoverable), and multiple suggestions for improvement. Usability problems with room layout were detected at one center and problems with hardware were detected at one center. Upon amalgamation and summary of the results, three key recommendations were presented to the document’s authors for incorporation into the electronic form. Documented inefficiencies and patient safety concerns related to the room layout and hardware were presented to administration along with a request for funding to purchase upgraded hardware and accessories to allow a more efficient workflow within the simulator vault. Conclusion: By including usability testing as part of the process when introducing any new document or procedure into clinical use, associated risks can be identified and mitigated before patient care and clinical workflow are impacted.« less
ERIC Educational Resources Information Center
Owolabi, Sola; Idowu, Oluwafemi A.; Okocha, Foluke; Ogundare, Atinuke Omotayo
2016-01-01
The study evaluated utilization of electronic information resources by undergraduates in the Faculties of Education and the Social Sciences in University of Ibadan. The study adopted a descriptive survey design with a study population of 1872 undergraduates in the Faculties of Education and the Social Sciences in University of Ibadan, from which a…
ERIC Educational Resources Information Center
Manchester Metropolitan Univ. (England).
This issues paper, eighth in a series of eight, is intended to distill formative evaluation questions on topics that are central to the development of the higher and further education information environment in the United Kingdom. This study focused on the searching behavior of higher education students as they attempted to locate electronic…
Mobile technology in radiology resident education.
Korbage, Aiham C; Bedi, Harprit S
2012-06-01
The authors hypothesized that ownership of a mobile electronic device would result in more time spent learning radiology. Current trends in radiology residents' studying habits, their use of electronic and printed radiology learning resources, and how much of the funds allotted to them are being used toward printed vs electronic education tools were assessed in this study. A survey study was conducted among radiology residents across the United States from June 13 to July 5, 2011. Program directors listed in the Association of Program Directors in Radiology e-mail list server received an e-mail asking for residents to participate in an online survey. The questionnaire consisted of 12 questions and assessed the type of institution, the levels of training of the respondents, and book funds allocated to residents. It also assessed the residents' study habits, access to portable devices, and use of printed and electronic radiology resources. Radiology residents are adopters of new technologies, with 74% owning smart phones and 37% owning tablet devices. Respondents spend nearly an equal amount of time learning radiology from printed textbooks as they do from electronic resources. Eighty-one percent of respondents believe that they would spend more time learning radiology if provided with tablet devices. There is considerable use of online and electronic resources and mobile devices among the current generation of radiology residents. Benefits, such as more study time, may be obtained by radiology programs that incorporate tablet devices into the education of their residents. Copyright © 2012 American College of Radiology. Published by Elsevier Inc. All rights reserved.
A.D. Wilson
2014-01-01
New electronic gas-detection methods were developed and tested for the diagnosis of bacterial wetwood disease in Fagus grandifolia (American beech) and Prunus serotina (black cherry) using a Conducting Polymer (CP)-type electronic nose (e-nose), the Aromascan A32S, based on detection of headspace...
Mukasa, Oscar; Mushi, Hildegalda P; Maire, Nicolas; Ross, Amanda; de Savigny, Don
2017-01-01
Data entry at the point of collection using mobile electronic devices may make data-handling processes more efficient and cost-effective, but there is little literature to document and quantify gains, especially for longitudinal surveillance systems. To examine the potential of mobile electronic devices compared with paper-based tools in health data collection. Using data from 961 households from the Rufiji Household and Demographic Survey in Tanzania, the quality and costs of data collected on paper forms and electronic devices were compared. We also documented, using qualitative approaches, field workers, whom we called 'enumerators', and households' members on the use of both methods. Existing administrative records were combined with logistics expenditure measured directly from comparison households to approximate annual costs per 1,000 households surveyed. Errors were detected in 17% (166) of households for the paper records and 2% (15) for the electronic records (p < 0.001). There were differences in the types of errors (p = 0.03). Of the errors occurring, a higher proportion were due to accuracy in paper surveys (79%, 95% CI: 72%, 86%) compared with electronic surveys (58%, 95% CI: 29%, 87%). Errors in electronic surveys were more likely to be related to completeness (32%, 95% CI 12%, 56%) than in paper surveys (11%, 95% CI: 7%, 17%).The median duration of the interviews ('enumeration'), per household was 9.4 minutes (90% central range 6.4, 12.2) for paper and 8.3 (6.1, 12.0) for electronic surveys (p = 0.001). Surveys using electronic tools, compared with paper-based tools, were less costly by 28% for recurrent and 19% for total costs. Although there were technical problems with electronic devices, there was good acceptance of both methods by enumerators and members of the community. Our findings support the use of mobile electronic devices for large-scale longitudinal surveys in resource-limited settings.
Kabir, Muhammad N.; Alginahi, Yasser M.
2014-01-01
This paper addresses the problems and threats associated with verification of integrity, proof of authenticity, tamper detection, and copyright protection for digital-text content. Such issues were largely addressed in the literature for images, audio, and video, with only a few papers addressing the challenge of sensitive plain-text media under known constraints. Specifically, with text as the predominant online communication medium, it becomes crucial that techniques are deployed to protect such information. A number of digital-signature, hashing, and watermarking schemes have been proposed that essentially bind source data or embed invisible data in a cover media to achieve its goal. While many such complex schemes with resource redundancies are sufficient in offline and less-sensitive texts, this paper proposes a hybrid approach based on zero-watermarking and digital-signature-like manipulations for sensitive text documents in order to achieve content originality and integrity verification without physically modifying the cover text in anyway. The proposed algorithm was implemented and shown to be robust against undetected content modifications and is capable of confirming proof of originality whilst detecting and locating deliberate/nondeliberate tampering. Additionally, enhancements in resource utilisation and reduced redundancies were achieved in comparison to traditional encryption-based approaches. Finally, analysis and remarks are made about the current state of the art, and future research issues are discussed under the given constraints. PMID:25254247
Barroso, Teresa G; Martins, Rui C; Fernandes, Elisabete; Cardoso, Susana; Rivas, José; Freitas, Paulo P
2018-02-15
Tuberculosis is one of the major public health concerns. This highly contagious disease affects more than 10.4 million people, being a leading cause of morbidity by infection. Tuberculosis is diagnosed at the point-of-care by the Ziehl-Neelsen sputum smear microscopy test. Ziehl-Neelsen is laborious, prone to human error and infection risk, with a limit of detection of 10 4 cells/mL. In resource-poor nations, a more practical test, with lower detection limit, is paramount. This work uses a magnetoresistive biosensor to detect BCG bacteria for tuberculosis diagnosis. Herein we report: i) nanoparticle assembly method and specificity for tuberculosis detection; ii) demonstration of proportionality between BCG cell concentration and magnetoresistive voltage signal; iii) application of multiplicative signal correction for systematic effects removal; iv) investigation of calibration effectiveness using chemometrics methods; and v) comparison with state-of-the-art point-of-care tuberculosis biosensors. Results present a clear correspondence between voltage signal and cell concentration. Multiplicative signal correction removes baseline shifts within and between biochip sensors, allowing accurate and precise voltage signal between different biochips. The corrected signal was used for multivariate regression models, which significantly decreased the calibration standard error from 0.50 to 0.03log 10 (cells/mL). Results show that Ziehl-Neelsen detection limits and below are achievable with the magnetoresistive biochip, when pre-processing and chemometrics are used. Copyright © 2017 Elsevier B.V. All rights reserved.
Brooks, Spencer W; Moore, Daniel R; Marzouk, Evan B; Glenn, Frasier R; Hallock, Robert M
2015-01-01
Olfactory cancer detection shows promise as an affordable, precise, and noninvasive way to screen for cancer. This review focuses on two methods of olfactory cancer detection: first, the ability of canines to differentiate between cancerous and healthy individuals through the use of biological samples and second, electronic nose technology that uses chemical sensors to detect known biomarkers in exhaled breath. This review summarizes and critiques past research and outlines future directions to improve understanding of both canine olfaction and electronic nose technology.
ERIC Educational Resources Information Center
Mahoney, Brian D.
2000-01-01
States that several states are establishing networks for resource sharing. Florida offers these resources through the Florida Distance Learning Library Initiative, Wisconsin has BadgerLink and WISCAT, TexShare provides library resource sharing in Texas, and Louisiana has LOUIS and LLN. These are some of the states successfully demonstrating…
The Status of Resources in Teacher Education.
ERIC Educational Resources Information Center
Yarger, Sam J.
This overview of the use of educational resources in teacher education discusses the concept of an educational resource as a reserve source of supply or support, and outlines a simple category system to describe the various types of educational resources: print, non-print, electronic/mechanical, management, intact, and human. The primary focus is…
Sub-GeV dark matter detection with electron recoils in carbon nanotubes
NASA Astrophysics Data System (ADS)
Cavoto, G.; Luchetta, F.; Polosa, A. D.
2018-01-01
Directional detection of Dark Matter particles (DM) in the MeV mass range could be accomplished by studying electron recoils in large arrays of parallel carbon nanotubes. In a scattering process with a lattice electron, a DM particle might transfer sufficient energy to eject it from the nanotube surface. An external electric field is added to drive the electron from the open ends of the array to the detection region. The anisotropic response of this detection scheme, as a function of the orientation of the target with respect to the DM wind, is calculated, and it is concluded that no direct measurement of the electron ejection angle is needed to explore significant regions of the light DM exclusion plot. A compact sensor, in which the cathode element is substituted with a dense array of parallel carbon nanotubes, could serve as the basic detection unit.
E-Nursing: electronic nursing resources on your desktop.
Kendall, Sandra; Massaralla, Susan; Hynes-Gay, Patricia; Vincent, Leslie
2003-01-01
E-Nursing represents an innovative approach to nursing education that has the potential to support professional practice throughout the institution. This paper details the benefits, design and promotion of an electronic nursing resource collection. How to divide responsibility, cost and expertise in such a project is also discussed. Preliminary usage statistics validate E-Nursing as a point-of-care education tool for nurses at Mount Sinai Hospital. A planned approach to implementation has been an effective means of introducing E-Nursing in an institution that previously relied on traditional hard-copy resources housed in the hospital's library.
Hendrix, Dean; Hasman, Linda
2008-01-01
Objective: The research sought to ascertain medical and dental libraries' collection development policies, evaluation methods, purchase decisions, and issues that relate to print and electronic United States Medical Licensing Examination (USMLE) and National Board Dental Examination (NBDE) preparation materials. Methods: The investigators surveyed librarians supporting American Association of Medical Colleges (AAMC)–accredited medical schools (n = 58/125) on the USMLE and librarians supporting American Dental Association (ADA)–accredited dental schools (n = 23/56) on the NBDE. The investigators analyzed the data by cross-tabulating and filtering the results using EFM Continuum web survey software. Investigators also surveyed print and electronic USMLE and NBDE preparation materials from 2004–2007 to determine the number of publications and existence of reviews. Results: A majority of responding AAMC libraries (62%, n = 58) provide at least 1 electronic or online USMLE preparation resource and buy an average of 11.6 print USMLE titles annually. Due to a paucity of NBDE print and electronic resources, ADA libraries bought significantly fewer print resources, and only 1 subscribed to an electronic resource. The most often reported evaluation methods for both populations were feedback from medical or dental students, feedback from medical or dental faculty, and online trials. Some AAMC (10%, n = 58) and ADA libraries (39%, n = 23) libraries reported that no evaluation of these materials occured at their libraries. Conclusions: From 2004–2007, publishers produced 45 USMLE preparation resources (total n = 546) to every 1 NBDE preparation resource (total n = 12). Users' needs, institutional missions and goals, financial status, and official collection policies most often underlie decisions to collect or not collect examination preparation materials. Evaluating the quality of examination preparation materials can be problematic due to lack of published reviews, lack of usability testing by libraries, and librarians' and library users' unfamiliarity with the actual content of examinations. Libraries must integrate faculty and students into the purchase process to make sure examination preparation resources of the highest quality are purchased. PMID:18654641
Transmission environmental scanning electron microscope with scintillation gaseous detection device.
Danilatos, Gerasimos; Kollia, Mary; Dracopoulos, Vassileios
2015-03-01
A transmission environmental scanning electron microscope with use of a scintillation gaseous detection device has been implemented. This corresponds to a transmission scanning electron microscope but with addition of a gaseous environment acting both as environmental and detection medium. A commercial type of low vacuum machine has been employed together with appropriate modifications to the detection configuration. This involves controlled screening of various emitted signals in conjunction with a scintillation gaseous detection device already provided with the machine for regular surface imaging. Dark field and bright field imaging has been obtained along with other detection conditions. With a progressive series of modifications and tests, the theory and practice of a novel type of microscopy is briefly shown now ushering further significant improvements and developments in electron microscopy as a whole. Copyright © 2014 Elsevier B.V. All rights reserved.
ERIC Educational Resources Information Center
Weiskel, Timothy C.
1991-01-01
An online system designed to help global environmental research, the electronic research system called Eco-Link draws data from various electronic sources including online catalogs and databases, CD-ROMs, electronic news sources, and electronic data subscription services to produce briefing booklets on environmental issues. It can be accessed by…
Methods of DNA methylation detection
NASA Technical Reports Server (NTRS)
Maki, Wusi Chen (Inventor); Filanoski, Brian John (Inventor); Mishra, Nirankar (Inventor); Rastogi, Shiva (Inventor)
2010-01-01
The present invention provides for methods of DNA methylation detection. The present invention provides for methods of generating and detecting specific electronic signals that report the methylation status of targeted DNA molecules in biological samples.Two methods are described, direct and indirect detection of methylated DNA molecules in a nano transistor based device. In the direct detection, methylated target DNA molecules are captured on the sensing surface resulting in changes in the electrical properties of a nano transistor. These changes generate detectable electronic signals. In the indirect detection, antibody-DNA conjugates are used to identify methylated DNA molecules. RNA signal molecules are generated through an in vitro transcription process. These RNA molecules are captured on the sensing surface change the electrical properties of nano transistor thereby generating detectable electronic signals.
Document Delivery: An Annotated Selective Bibliography.
ERIC Educational Resources Information Center
Khalil, Mounir A.; Katz, Suzanne R.
1992-01-01
Presents a selective annotated bibliography of 61 items that deal with topics related to document delivery, including networks; hypertext; interlibrary loan; computer security; electronic publishing; copyright; online catalogs; resource sharing; electronic mail; electronic libraries; optical character recognition; microcomputers; liability issues;…
The importance of measuring fuel consumption in evaluating electronic clearance
DOT National Transportation Integrated Search
1998-01-01
Electronic screening of commercial vehicles at weigh stations is important to enforcement agencies and motor carriers as it allows both parties to use their resources more efficiently. This paper studies the effects of electronic screening on reducin...
The X-ray Detectability of Electron Beams Escaping from the Sun
NASA Astrophysics Data System (ADS)
Saint-Hilaire, Pascal; Krucker, Säm; Christe, Steven; Lin, Robert P.
2009-05-01
We study the detectability and characterization of electron beams as they leave their acceleration site in the low corona toward interplanetary space through their nonthermal X-ray bremsstrahlung emission. We demonstrate that the largest interplanetary electron beams (gsim1035 electrons above 10 keV) can be detected in X-rays with current and future instrumentation, such as RHESSI or the X-Ray Telescope (XRT) onboard Hinode. We make a list of optimal observing conditions and beam characteristics. Amongst others, good imaging (as opposed to mere localization or detection in spatially integrated data) is required for proper characterization, putting the requirement on the number of escaping electrons (above 10 keV) to gsim3 × 1036 for RHESSI, gsim3 × 1035 for Hinode/XRT, and gsim1033 electrons for the FOXSI sounding rocket scheduled to fly in 2011. Moreover, we have found that simple modeling hints at the possibility that coronal soft X-ray jets could be the result of local heating by propagating electron beams.
ERIC Educational Resources Information Center
Scharf, Davida
2002-01-01
Discussion of improving accessibility to copyrighted electronic content focuses on the Digital Object Identifier (DOI) and the Open URL standard and linking software. Highlights include work of the World Wide Web consortium; URI (Uniform Resource Identifier); URL (Uniform Resource Locator); URN (Uniform Resource Name); OCLC's (Online Computer…
Reversal electron attachment ionizer for detection of trace species
NASA Technical Reports Server (NTRS)
Bernius, Mark T. (Inventor); Chutjian, Ara (Inventor)
1990-01-01
An in-line reversal electron, high-current ionizer capable of focusing a beam of electrons to a reversal region and executing a reversal of said electrons, such that the electrons possess zero kinetic energy at the point of reversal, may be used to produce both negative and positive ions. A sample gas is introduced at the point of electron reversal for low energy electron-(sample gas) molecule attachment with high efficiency. The attachment process produces negative ions from the sample gas, which includes species present in trace (minute) amounts. These ions are extracted efficiently and directed to a mass analyzer where they may be detected and identified. The generation and detection of positive ions is accomplished in a similar fashion with minimal adjustment to potentials applied to the apparatus.
Reversal electron attachment ionizer for detection of trace species
NASA Technical Reports Server (NTRS)
Bernius, Mark T. (Inventor); Chutjian, Ara (Inventor)
1989-01-01
An in-line reversal electron, high-current ionizer capable of focusing a beam of electrons to a reversal region and executing a reversal of the electrons, such that the electrons possess zero kinetic energy at the point of reversal, may be used to produce both negative and positive ions. A sample gas is introduced at the point of electron reversal for low energy electron-(sample gas) molecule attachment with high efficiency. The attachment process produces negative ions from the sample gas, which includes species present in trace (minute) amounts. These ions are extracted efficiently and directed to a mass analyzer where they may be detected and identified. The generation and detection of positive ions is accomplished in a similar fashion with minimal adjustment to potentials applied to the apparatus.
The Use of Electronic Resources by Academic Staff at the University of Ilorin, Nigeria
ERIC Educational Resources Information Center
Tella, Adeyinka; Orim, Faith; Ibrahim, Dauda Morenikeji; Memudu, Suleiman Ajala
2018-01-01
The use of e-resources is now commonplace among academics in tertiary educational institutions the world over. Many academics including those in the universities are exploring the opportunities of e-resources to facilitate teaching and research. As the use of e-resources is increasing particularly among academics at the University of Ilorin,…
A Guide to Internet Resources in Language Arts.
ERIC Educational Resources Information Center
Homme, John, Comp.; And Others
This paper presents a list of 154 Internet resources (listservs, freenets, telnet sites, gophers, etc.) dealing with language arts. Each entry in the list includes the name of the resource, and subscription and electronic mail addresses. Some of the entries in the list include a brief description of the resource. The paper lists 17 language arts…
Resource Sharing in an Electronic Age: Past, Present, and Future.
ERIC Educational Resources Information Center
Jones, Adrian
Librarians' work has become more challenging and complex over the past 15 years. Fifteen years ago, the telephone was a librarian's most used and most effective instrument, and librarians mostly relied on the resources within their own walls. In that era, resource sharing placed substantial burdens on larger libraries, and the resources of smaller…
Bioelectrochemical Biorefining
DOE Office of Scientific and Technical Information (OSTI.GOV)
Borole, Abhijeet P.
2017-12-01
Bioelectrochemical biorefining is a new concept which has evolved from the field of microbial fuel cells and electrolysis cells. It targets integration of microbial electrochemical cells into the biorefinery. The idea is to use low value resources to generate electrons and then use the electrons to produce value-added products. This can enable production of fuels and chemicals from waste and biomass using electrons as intermediates. Thus, the name: Bioelectrochemical Biorefining. Electrons are the simplest and most common ‘energy carriers’ of many energy transfer systems and energetic molecules. Thus, using them as the vehicle for conversion of existing renewable resources intomore » products needed for the 21st century is the primary goal of this marriage between microbial electrochemical technology and biorefineries.« less
48 CFR 1339.270 - Solicitation provisions and contract clauses.
Code of Federal Regulations, 2011 CFR
2011-10-01
... COMMERCE SPECIAL CATEGORIES OF CONTRACTING ACQUISITION OF INFORMATION TECHNOLOGY Electronic and Information... to 1352.239-71, Electronic and Information Technology, in solicitations for Electronic and... Technology Resources, in all DOC solicitations and contracts for Information Technology services. The clause...
48 CFR 1339.270 - Solicitation provisions and contract clauses.
Code of Federal Regulations, 2014 CFR
2014-10-01
... COMMERCE SPECIAL CATEGORIES OF CONTRACTING ACQUISITION OF INFORMATION TECHNOLOGY Electronic and Information... to 1352.239-71, Electronic and Information Technology, in solicitations for Electronic and... Technology Resources, in all DOC solicitations and contracts for Information Technology services. The clause...
48 CFR 1339.270 - Solicitation provisions and contract clauses.
Code of Federal Regulations, 2013 CFR
2013-10-01
... COMMERCE SPECIAL CATEGORIES OF CONTRACTING ACQUISITION OF INFORMATION TECHNOLOGY Electronic and Information... to 1352.239-71, Electronic and Information Technology, in solicitations for Electronic and... Technology Resources, in all DOC solicitations and contracts for Information Technology services. The clause...
Utilizing Existing Clinical and Population Biospecimen Resources for Discovery or Validation of Markers for Early Cancer Detection, a 2013 workshop sponsored by the Epidemiology and Genomics Research Program.
Historical Collections | Alaska State Library
Microfilm eResources Electronic Books (EBSCO) World Catalog (WorldCat) Free Images and Sounds Journal Finder Publications Catalog and Library Card Info Federal Publications Free Images and Sounds Library Resources Articles & Databases Free Images & Sounds Journal Finder Library Resources Live Homework Help
Resources for the Practitioner.
ERIC Educational Resources Information Center
Hackeling, Joan, Comp.
2003-01-01
This list of print and electronic resources is designed to act as a springboard to assist practitioners in finding information to start implementing sustainability efforts on their campuses. The resources are listed in the following categories: general, international, K-12, policy/partnerships, campus environmental assessments, green building,…
Electrical detection of nuclear spins in organic light-emitting diodes
NASA Astrophysics Data System (ADS)
Malissa, H.; Kavand, M.; Waters, D. P.; Lupton, J. M.; Vardeny, Z. V.; Saam, B.; Boehme, C.
2014-03-01
We present pulsed combined electrically detected electron paramagnetic and nuclear magnetic resonance experiments on MEH-PPV OLEDs. Spin dynamics in these structures are governed by hyperfine interactions between charge carriers and the surrounding hydrogen nuclei, which are abundant in these materials. Hyperfine coupling has been observed by monitoring the device current during coherent spin excitation. Electron spin echoes (ESEs) are detected by applying one additional readout pulse at the time of echo formation. This allows for the application of high-resolution spectroscopy based on ESE detection, such as electron spin echo envelope modulation (ESEEM) and electron nuclear double resonance (ENDOR) available for electrical detection schemes. We conduct electrically detected ESEEM and ENDOR experiments and show how hyperfine interactions in MEH-PPV with and without deuterated polymer side groups can be observed by device current measurements. We acknowledge support by the Department of Energy, Office of Basic Energy Sciences under Award #DE-SC0000909.
Mazloomdoost, Danesh; Mehregan, Shervineh; Mahmoudi, Hilda; Soltani, Akbar; Embi, Peter J.
2007-01-01
Studies performed in the US and other Western countries have documented that physicians generate many clinical questions during a typical day and rely on various information sources for answers. Little is known about the information seeking behaviors of physicians practicing in other countries, particularly those with limited Internet connectivity. We conducted this study to document the perceived barriers to information resources used by medical residents in Iran. Our findings reveal that different perceived barriers exist for electronic versus paper-based resources. Notably, paper-based resources are perceived to be limited by resident time-constraints and availability of resources, whereas electronic resources are limited by cost decentralized resources (such as PDAs) and accessibility of centralized, Internet access. These findings add to the limited literature regarding health information-seeking activities in international healthcare settings, particularly those with limited Internet connectivity, and will supplement future studies of and interventions in such settings. PMID:18693891
Mazloomdoost, Danesh; Mehregan, Shervineh; Mahmoudi, Hilda; Soltani, Akbar; Embi, Peter J
2007-10-11
Studies performed in the US and other Western countries have documented that physicians generate many clinical questions during a typical day and rely on various information sources for answers. Little is known about the information seeking behaviors of physicians practicing in other countries, particularly those with limited Internet connectivity. We conducted this study to document the perceived barriers to information resources used by medical residents in Iran. Our findings reveal that different perceived barriers exist for electronic versus paper-based resources. Notably, paper-based resources are perceived to be limited by resident time-constraints and availability of resources, whereas electronic resources are limited by cost decentralized resources (such as PDAs) and accessibility of centralized, Internet access. These findings add to the limited literature regarding health information-seeking activities in international healthcare settings, particularly those with limited Internet connectivity, and will supplement future studies of and interventions in such settings.
NASA Technical Reports Server (NTRS)
Couch, Richard H.; Rowland, Carroll W.; Ellis, K. Scott; Blythe, Michael P.; Regan, Curtis P.; Koch, Michael R.; Antill, Charles W.; Kitchen, Wayne L.; Cox, John W.; Delorme, Joseph F.
1991-01-01
Engineering aspects are presented of the design, fabrication, integration, and operation of the Lidar In-Space Technology Experiment (LITE) for flight aboard the Space Shuttle in mid-1993. The LITE system is being developed by NASA/Langley Research Center and will be used to detect stratospheric and tropospheric aerosols, probe the planetary boundary layer, measure cloud top heights, and measure atmospheric temperature and density in the 10- to 40-km range. The system consists of a nominal telescope receiver 1 meter in diameter, a three-color Nd:YAG laser transmitter, and the system electronics. The system makes extensive use of Space Shuttle resources for electrical power, thermal control, and command and data handling.
McHenry, Megan S; Fischer, Lydia J; Chun, Yeona; Vreeman, Rachel C
2017-08-01
The objective of this study is to conduct a systematic review of the literature of how portable electronic technologies with offline functionality are perceived and used to provide health education in resource-limited settings. Three reviewers evaluated articles and performed a bibliography search to identify studies describing health education delivered by portable electronic device with offline functionality in low- or middle-income countries. Data extracted included: study population; study design and type of analysis; type of technology used; method of use; setting of technology use; impact on caregivers, patients, or overall health outcomes; and reported limitations. Searches yielded 5514 unique titles. Out of 75 critically reviewed full-text articles, 10 met inclusion criteria. Study locations included Botswana, Peru, Kenya, Thailand, Nigeria, India, Ghana, and Tanzania. Topics addressed included: development of healthcare worker training modules, clinical decision support tools, patient education tools, perceptions and usability of portable electronic technology, and comparisons of technologies and/or mobile applications. Studies primarily looked at the assessment of developed educational modules on trainee health knowledge, perceptions and usability of technology, and comparisons of technologies. Overall, studies reported positive results for portable electronic device-based health education, frequently reporting increased provider/patient knowledge, improved patient outcomes in both quality of care and management, increased provider comfort level with technology, and an environment characterized by increased levels of technology-based, informal learning situations. Negative assessments included high investment costs, lack of technical support, and fear of device theft. While the research is limited, portable electronic educational resources present promising avenues to increase access to effective health education in resource-limited settings, contingent on the development of culturally adapted and functional materials to be used on such devices.
Woo, Victoria Gah Hay; Cohen, Craig R; Bukusi, Elizabeth A; Huchko, Megan J
2013-02-01
In resource-limited settings, detection of sexually transmitted infections (STIs) often relies on self-reported symptoms to initiate management. We found self-report demonstrated poor sensitivity for STI detection. Adding clinician-initiated questions about symptoms improved detection rates. Vaginal examination further increased sensitivity. Including clinician-initiated screening in resource-limited settings would improve management of treatable STIs.
Tang, Shisong; Vinerot, Nataly; Fisher, Danny; Bulatov, Valery; Yavetz-Chen, Yehuda; Schechter, Israel
2016-08-01
Multiphoton electron extraction spectroscopy (MEES) is an analytical method in which UV laser pulses are utilized for extracting electrons from solid surfaces in multiphoton processes under ambient conditions. Counting the emitted electrons as a function of laser wavelength results in detailed spectral features, which can be used for material identification. The method has been applied to detection of trace explosives on a variety of surfaces. Detection was possible on dusty swabs spiked with explosives and also in the standard dry-transfer contamination procedure. Plastic explosives could also be detected. The analytical limits of detection (LODs) are in the sub pmole range, which indicates that MEES is one of the most sensitive detection methods for solid surface under ambient conditions. Scanning the surface with the laser allows for its imaging, such that explosives (as well as other materials) can be located. The imaging mode is also useful in forensic applications, such as detection of explosives in human fingerprints. Copyright © 2016 Elsevier B.V. All rights reserved.
Preliminary Radiation Analysis of the Total Ionizing Dose for the Resource Prospector Mission
NASA Technical Reports Server (NTRS)
Rojdev, Kristina; Tylka, Allan J.; Atwell, William
2015-01-01
NASA's Resource Prospector (RP) is a collaborative project between multiple centers and institutions to search for volatiles at the polar regions of the Moon as a potential resource for oxygen and propellant production. The mission is rated Class D and will be the first In-Situ Resource Utilization (ISRU) demonstration on the lunar surface and at the lunar poles. Given that this mission is rated Class D, the project is considering using commercial off the shelf (COTS) electronics parts to reduce cost. However, COTS parts can be more susceptible to space radiation than typical aerospace electronic parts and carry some additional risk. Thus, prior to parts selection, having a better understanding of the radiation environment can assist designers in the parts selection process. The focus of this paper is to provide a preliminary analysis of the radiation environment from launch, through landing on the surface, and some surface stay as an initial step in determining worst case mission doses to assist designers in screening out electronic parts that would not meet the potential dose levels experienced on this mission.
Kamel Boulos, M N; Roudsari, A V; Gordon, C; Muir Gray, J A
2001-01-01
In 1998, the U.K. National Health Service Information for Health Strategy proposed the implementation of a National electronic Library for Health to provide clinicians, healthcare managers and planners, patients and the public with easy, round the clock access to high quality, up-to-date electronic information on health and healthcare. The Virtual Branch Libraries are among the most important components of the National electronic Library for Health. They aim at creating online knowledge based communities, each concerned with some specific clinical and other health-related topics. This study is about the envisaged Dermatology Virtual Branch Libraries of the National electronic Library for Health. It aims at selecting suitable dermatology Web resources for inclusion in the forthcoming Virtual Branch Libraries after establishing preliminary quality benchmarking rules for this task. Psoriasis, being a common dermatological condition, has been chosen as a starting point. Because quality is a principal concern of the National electronic Library for Health, the study includes a review of the major quality benchmarking systems available today for assessing health-related Web sites. The methodology of developing a quality benchmarking system has been also reviewed. Aided by metasearch Web tools, candidate resources were hand-selected in light of the reviewed benchmarking systems and specific criteria set by the authors. Over 90 professional and patient-oriented Web resources on psoriasis and dermatology in general are suggested for inclusion in the forthcoming Dermatology Virtual Branch Libraries. The idea of an all-in knowledge-hallmarking instrument for the National electronic Library for Health is also proposed based on the reviewed quality benchmarking systems. Skilled, methodical, organized human reviewing, selection and filtering based on well-defined quality appraisal criteria seems likely to be the key ingredient in the envisaged National electronic Library for Health service. Furthermore, by promoting the application of agreed quality guidelines and codes of ethics by all health information providers and not just within the National electronic Library for Health, the overall quality of the Web will improve with time and the Web will ultimately become a reliable and integral part of the care space.
ERIC Educational Resources Information Center
Kaser, Richard T.; Johnson, Richard K.; Rudner, Lawrence
2000-01-01
Discusses Fair Use and the public perception; models for funding information services; publishers illusion that information is/should be free; Internet's role in making information freely available; scholarly communication systems: Scholarly Publishing and Academic Resources Coalition (SPARC) and BioOne (an electronic aggregation of bioscience…
Electronic Commerce: Government Services in the New Millennium.
ERIC Educational Resources Information Center
Maxwell, Terrence A., Ed.
1998-01-01
This newsletter features innovations in resource management and information technology to support New York State government. The newsletter contains the following six sections: (1) "Electronic Commerce: Government Services in the New Millennium" -- examining the need for government involvement in electronic commerce policy and…
Gambling revenues as a public administration issue: electronic gaming machines in Victoria.
Pickernell, David; Keast, Robyn; Brown, Kerry; Yousefpour, Nina; Miller, Chris
2013-12-01
Gambling activities and the revenues derived have been seen as a way to increase economic development in deprived areas. There are also, however, concerns about the effects of gambling in general and electronic gaming machines (EGMs) in particular, on the resources available to the localities in which they are situated. This paper focuses on the factors that determine the extent and spending of community benefit-related EGM-generated resources within Victoria, Australia, focusing in particular on the relationships between EGM activity and socio-economic and social capital indicators, and how this relates to the community benefit resources generated by gaming.
For State Employees | Alaska State Library
Microfilm eResources Electronic Books (EBSCO) World Catalog (WorldCat) Free Images and Sounds Journal Finder Publications Catalog and Library Card Info Federal Publications Free Images and Sounds Library Resources Articles & Databases Free Images & Sounds Journal Finder Library Resources Live Homework Help
HEATH National Resource Directory on Postsecondary Education and Disability 1996.
ERIC Educational Resources Information Center
Barr, Vickie M., Ed.
This biennial directory lists a variety of selected resources in the field of postsecondary education and disability, including independent organizations, governmental agencies, and technology-related resources. Listings usually provide name (or title), address, electronic-mail address, telephone number, facsimile number, and a brief description.…
Emotional Intelligence Research within Human Resource Development Scholarship
ERIC Educational Resources Information Center
Farnia, Forouzan; Nafukho, Fredrick Muyia
2016-01-01
Purpose: The purpose of this study is to review and synthesize pertinent emotional intelligence (EI) research within the human resource development (HRD) scholarship. Design/methodology/approach: An integrative review of literature was conducted and multiple electronic databases were searched to find the relevant resources. Using the content…
Detection of a strongly negative surface potential at Saturn's moon Hyperion.
Nordheim, T A; Jones, G H; Roussos, E; Leisner, J S; Coates, A J; Kurth, W S; Khurana, K K; Krupp, N; Dougherty, M K; Waite, J H
2014-10-28
On 26 September 2005, Cassini conducted its only close targeted flyby of Saturn's small, irregularly shaped moon Hyperion. Approximately 6 min before the closest approach, the electron spectrometer (ELS), part of the Cassini Plasma Spectrometer (CAPS) detected a field-aligned electron population originating from the direction of the moon's surface. Plasma wave activity detected by the Radio and Plasma Wave instrument suggests electron beam activity. A dropout in energetic electrons was observed by both CAPS-ELS and the Magnetospheric Imaging Instrument Low-Energy Magnetospheric Measurement System, indicating that the moon and the spacecraft were magnetically connected when the field-aligned electron population was observed. We show that this constitutes a remote detection of a strongly negative (∼ -200 V) surface potential on Hyperion, consistent with the predicted surface potential in regions near the solar terminator.
Optimal surveillance strategy for invasive species management when surveys stop after detection.
Guillera-Arroita, Gurutzeta; Hauser, Cindy E; McCarthy, Michael A
2014-05-01
Invasive species are a cause for concern in natural and economic systems and require both monitoring and management. There is a trade-off between the amount of resources spent on surveying for the species and conducting early management of occupied sites, and the resources that are ultimately spent in delayed management at sites where the species was present but undetected. Previous work addressed this optimal resource allocation problem assuming that surveys continue despite detection until the initially planned survey effort is consumed. However, a more realistic scenario is often that surveys stop after detection (i.e., follow a "removal" sampling design) and then management begins. Such an approach will indicate a different optimal survey design and can be expected to be more efficient. We analyze this case and compare the expected efficiency of invasive species management programs under both survey methods. We also evaluate the impact of mis-specifying the type of sampling approach during the program design phase. We derive analytical expressions that optimize resource allocation between monitoring and management in surveillance programs when surveys stop after detection. We do this under a scenario of unconstrained resources and scenarios where survey budget is constrained. The efficiency of surveillance programs is greater if a "removal survey" design is used, with larger gains obtained when savings from early detection are high, occupancy is high, and survey costs are not much lower than early management costs at a site. Designing a surveillance program disregarding that surveys stop after detection can result in an efficiency loss. Our results help guide the design of future surveillance programs for invasive species. Addressing program design within a decision-theoretic framework can lead to a better use of available resources. We show how species prevalence, its detectability, and the benefits derived from early detection can be considered.
Hillenburg, K L; Cederberg, R A; Gray, S A; Hurst, C L; Johnson, G K; Potter, B J
2006-08-01
The digital revolution and growth of the Internet have led to many innovations in the area of electronic learning (e-learning). To survive and prosper, educators must be prepared to respond creatively to these changes. Administrators and information technology specialists at six dental schools and their parent institutions were interviewed regarding their opinions of the impact that e-learning will have on the future of dental education. Interview questions encompassed vision, rate of change, challenges, role of faculty, resources, enrolment, collaboration, responsibility for course design and content, mission and fate of the institution. The objective of this qualitative study was to sample the opinions of educational administrators and information technology specialists from selected US universities regarding the impact of e-learning on dental education to detect trends in their attitudes. Responses to the survey indicated disagreement between administrators and informational technology specialists regarding the rate of change, generation of resources, impact on enrolment, responsibility for course design and content, mission and fate of the university. General agreement was noted with regard to vision, challenges, role of faculty and need for collaboration.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hickling, S; El Naqa, I
Purpose: Previous work has demonstrated the detectability of acoustic waves induced following the irradiation of high density metals with radiotherapy linac photon beams. This work demonstrates the ability to experimentally detect such acoustic signals following both photon and electron irradiation in a more radiotherapy relevant material. The relationship between induced acoustic signal properties in water and the deposited dose distribution is explored, and the feasibility of exploiting such signals for radiotherapy dosimetry is demonstrated. Methods: Acoustic waves were experimentally induced in a water tank via the thermoacoustic effect following a single pulse of photon or electron irradiation produced by amore » clinical linac. An immersion ultrasound transducer was used to detect these acoustic waves in water and signals were read out on an oscilloscope. Results: Peaks and troughs in the detected acoustic signals were found to correspond to the location of gradients in the deposited dose distribution following both photon and electron irradiation. Signal amplitude was linearly related to the dose per pulse deposited by photon or electron beams at the depth of detection. Flattening filter free beams induced large acoustic signals, and signal amplitude decreased with depth after the depth of maximum dose. Varying the field size resulted in a temporal shift of the acoustic signal peaks and a change in the detected signal frequency. Conclusion: Acoustic waves can be detected in a water tank following irradiation by linac photon and electron beams with basic electronics, and have characteristics related to the deposited dose distribution. The physical location of dose gradients and the amount of dose deposited can be inferred from the location and magnitude of acoustic signal peaks. Thus, the detection of induced acoustic waves could be applied to photon and electron water tank and in vivo dosimetry. This work was supported in part by CIHR grants MOP-114910 and MOP-136774. S.H. acknowledges support by the NSERC CREATE Medical Physics Research Training Network grant 432290.« less
Herbst de Cortina, Sasha; Bristow, Claire C; Humphries, Romney; Vargas, Silver Keith; Konda, Kelika A; Caceres, Carlos F; Klausner, Jeffrey D
2017-07-01
Dual point-of-care tests for antibodies to human immunodeficiency virus (HIV) and Treponema pallidum allow for same-day testing and treatment and have been demonstrated to be cost-effective in preventing the adverse outcomes of HIV infection and syphilis. By recording and transmitting data as they are collected, electronic readers address challenges related to the decentralization of point-of-care testing. We evaluated a smartphone-based electronic reader using 201 sera tested with 2 dual rapid tests for detection of antibodies to HIV and T. pallidum in Los Angeles, USA, and Lima, Peru. Tests were read both visually and with the electronic reader. Enzyme immunoassay followed by Western blot and T. pallidum particle agglutination were the reference tests for HIV and T. pallidum, respectively. The sensitivities of the 2 rapid tests for detection of HIV were 94.1% and 97.0% for electronic readings. Both tests had a specificity of 100% for detection of HIV by electronic reading. The sensitivities of the 2 rapid tests for detection of T. pallidum were 86.5% and 92.4% for electronic readings. The specificities for detection of T. pallidum were 99.1% and 99.0% by electronic reading. There were no significant differences between the accuracies of visual and electronic readings, and the performance did not differ between the 2 study sites. Our results show the electronic reader to be a promising option for increasing the use of point-of-care testing programs.
THE X-RAY DETECTABILITY OF ELECTRON BEAMS ESCAPING FROM THE SUN
DOE Office of Scientific and Technical Information (OSTI.GOV)
Saint-Hilaire, Pascal; Krucker, Saem; Christe, Steven
2009-05-01
We study the detectability and characterization of electron beams as they leave their acceleration site in the low corona toward interplanetary space through their nonthermal X-ray bremsstrahlung emission. We demonstrate that the largest interplanetary electron beams ({approx}>10{sup 35} electrons above 10 keV) can be detected in X-rays with current and future instrumentation, such as RHESSI or the X-Ray Telescope (XRT) onboard Hinode. We make a list of optimal observing conditions and beam characteristics. Amongst others, good imaging (as opposed to mere localization or detection in spatially integrated data) is required for proper characterization, putting the requirement on the number ofmore » escaping electrons (above 10 keV) to {approx}>3 x 10{sup 36} for RHESSI, {approx}>3 x 10{sup 35} for Hinode/XRT, and {approx}>10{sup 33} electrons for the FOXSI sounding rocket scheduled to fly in 2011. Moreover, we have found that simple modeling hints at the possibility that coronal soft X-ray jets could be the result of local heating by propagating electron beams.« less
E-Book versus Printed Materials: Preferences of University Students
ERIC Educational Resources Information Center
Cumaoglu, Gonca; Sacici, Esra; Torun, Kerem
2013-01-01
Reading habits, accessing resources, and material preferences change rapidly in a digital world. University students, as digital natives, are accessing countless resources, from lecture notes to research papers electronically. The change of reading habits with a great scale has led to differentiation on accessibility of resources, archiving them…
ERIC Educational Resources Information Center
Blodgett, Teresa; Repman, Judi
1995-01-01
Addresses the necessity of incorporating new computer technologies into school library resource centers and notes some administrative challenges. An extensive checklist is provided for assessing equipment and furniture needs, physical facilities, and rewiring needs. A glossary of 20 terms and 11 additional resources is included. (AEF)
The Use of MERLOT in Biochemistry and Molecular Biology Education
ERIC Educational Resources Information Center
Cooper, Scott
2005-01-01
The referatory, Multimedia Educational Resources for Learning and Online Teaching (MERLOT), contains links to 1300 electronic teaching resources in biology and chemistry. Approximately 20% have been peer reviewed, and most have user comments or assignments attached. In addition to being a source of educational resources, the MERLOT project seeks…
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-20
... Resources, Systems Pros, Total Tech Services, Triple Crown Consulting, and Ingenium Technology, Inc... Resources, PDS Technical Service, Superior Technical Resources, Systems Pros, Total Tech Services, and... subject firm. The company reports that workers leased from Ingenium Technology, Inc. were employed on-site...
Electronic Training at the Corporate Level in Egypt: Applicability and Effectiveness
ERIC Educational Resources Information Center
Kamel, S.; Ibrahim, M.
2003-01-01
Declining revenue, staff downsizing and limited resources in corporations create serious organizational challenges. Training and human resources departments are often among the most adversely affected. Training managers are left with fewer resources with which to fulfil corporate training needs. Continuously having to justify costs and investments…
The World Wide Web Has Arrived--Science Educators Must All Get Aboard It.
ERIC Educational Resources Information Center
Didion, Catherine Jay
1997-01-01
Discusses the importance of science educators becoming familiar with electronic resources. Highlights the publication Science Teaching Reconsidered: A Handbook, which is designed to help undergraduate science educators. Addresses gender concerns regarding the use of educational resources. Lists science education and career resources on the web.…
Internet and Electronic Information Management
2004-12-01
centers to form consortia and share electronic information sources. Although traditional resource sharing arrangements encouraged competition rather...outside world, through public relations and through marketing information products or services, to its own competitive advantage (Davenport 1997: 193-217... electronic information sources are a challenge for electronic information managers. Libraries and information centers are no longer “the only game in town
NASA Astrophysics Data System (ADS)
Schaibley, John; Burgers, Alex; McCracken, Greg; Duan, Luming; Berman, Paul; Steel, Duncan; Bracker, Allan; Gammon, Daniel; Sham, Lu
2013-03-01
A single electron spin confined to a single InAs quantum dot (QD) can serve as a qubit for quantum information processing. By utilizing the QD's optically excited trion states in the presence of an externally applied magnetic field, the QD spin can be rapidly initialized, manipulated and read out. A key resource for quantum information is the ability to entangle distinct QD spins. One approach relies on intermediate spin-photon entanglement to mediate the entanglement between distant QD spin qubits. We report a demonstration of quantum entanglement between a photon's polarization state and the spin state of a single electron confined to a single QD. Here, the photon is spontaneously emitted from one of the QD's trion states. The emitted photon's polarization along the detection axis is entangled with the resulting spin state of the QD. By performing projective measurements on the photon's polarization state and correlating these measurements with the state of the QD spin in two different bases, we obtain a lower bound on the entanglement fidelity of 0.59 (after background correction). The fidelity bound is limited almost entirely by the timing resolution of our single photon detector. The spin-photon entanglement generation rate is 3 ×103 s-1. Supported by: NSF, MURI, AFOSR, DARPA, ARO.
78 FR 35262 - Detection and Avoidance of Counterfeit Electronic Parts
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-12
... DEPARTMENT OF DEFENSE Defense Acquisition Regulations System [DFARS Case 2012-D055] Detection and Avoidance of Counterfeit Electronic Parts AGENCY: Defense Acquisition Regulations System, Department of... detection and avoidance coverage proposed to be included in the Defense Federal Acquisition Regulation...
2011-05-10
concert with existing surveillance applications or the SAGES tools may be used en masse for an end-to-end biosurveillance capability. This flexibility...existing surveillance applications or the SAGES tools may be used en masse for an end–to-end biosurveillance capability. doi:10.1371/journal.pone...health resources, and the costs of proprietary software. The Suite for Automated Global Electronic bioSurveillance (SAGES) is a collection of modular
Kostenbauder, Adnah G.
1988-01-01
A photodetector for detecting signal pulses transmitted in an optical carrier signal relies on the generation of electron-hole pairs and the diffusion of the generated electrons and holes to the electrodes on the surface of the semiconductor detector body for generating photovoltaic pulses. The detector utilizes the interference of optical waves for generating an electron-hole grating within the semiconductor body, and, by establishing an electron-hole pair maximum at one electrode and a minimum at the other electrode, a detectable voltaic pulse is generated across the electrode.
Kostenbauder, A.G.
1988-06-28
A photodetector for detecting signal pulses transmitted in an optical carrier signal relies on the generation of electron-hole pairs and the diffusion of the generated electrons and holes to the electrodes on the surface of the semiconductor detector body for generating photovoltaic pulses. The detector utilizes the interference of optical waves for generating an electron-hole grating within the semiconductor body, and, by establishing an electron-hole pair maximum at one electrode and a minimum at the other electrode, a detectable voltaic pulse is generated across the electrode. 4 figs.
10th Annual Systems Engineering Conference: Volume 2 Wednesday
2007-10-25
intelligently optimize resource performance. Self - Healing Detect hardware/software failures and reconfigure to permit continued operations. Self ...Types Wake Ice WEAPON/PLATFORM ACOUSTICS Self -Noise Radiated Noise Beam Forming Pulse Types Submarines, surface ships, and platform sensors P r o p P r o...Computing Self -Protecting Detect internal/external attacks and protect it’s resources from exploitation. Self -Optimizing Detect sub-optimal behaviors and
Electronic Reference Service: A Teen's Eye View.
ERIC Educational Resources Information Center
Farmer, Lesley S.
2003-01-01
Discusses electronic reference service from a teen's point of view and from the school library media specialist's view. Considers traits that attract teens, including anonymity, speed, and convenience; and explains concerns of media specialists, including quality of electronic resources, how to provide access, library instruction options, and…
The Evolution of the School Library Collection: Implications for Effective Management.
ERIC Educational Resources Information Center
Debowski, Shelda
1999-01-01
Explores some of the collection and service-related issues which should be considered by those developing an electronic collection in a school library. Highlights include principles of electronic collection management; selection of electronic resources; technological infrastructure; user training; online subscriptions; marketing; and technical…
Measurement of Cosmic-Ray TeV Electrons
NASA Astrophysics Data System (ADS)
Schubnell, Michael; Anderson, T.; Bower, C.; Coutu, S.; Gennaro, J.; Geske, M.; Mueller, D.; Musser, J.; Nutter, S.; Park, N.; Tarle, G.; Wakely, S.
2011-09-01
The Cosmic Ray Electron Synchrotron Telescope (CREST) high-altitude balloon experiment is a pathfinding effort to detect for the first time multi-TeV cosmic-ray electrons. At these energies distant sources will not contribute to the local electron spectrum due to the strong energy losses of the electrons and thus TeV observations will reflect the distribution and abundance of nearby acceleration sites. CREST will detect electrons indirectly by measuring the characteristic synchrotron photons generated in the Earth's magnetic field. The instrument consist of an array of 1024 BaF2 crystals viewed by photomultiplier tubes surrounded by a hermetic scintillator shield. Since the primary electron itself need not traverse the payload, an effective detection area is achieved that is several times the nominal 6.4 m2 instrument. CREST is scheduled to fly in a long duration circumpolar orbit over Antarctica during the 2011-12 season.
Research about Memory Detection Based on the Embedded Platform
NASA Astrophysics Data System (ADS)
Sun, Hao; Chu, Jian
As is known to us all, the resources of memory detection of the embedded systems are very limited. Taking the Linux-based embedded arm as platform, this article puts forward two efficient memory detection technologies according to the characteristics of the embedded software. Especially for the programs which need specific libraries, the article puts forwards portable memory detection methods to help program designers to reduce human errors,improve programming quality and therefore make better use of the valuable embedded memory resource.
Section 508 Standards Resources
Learn which software applications, operating systems, web-based applications, and other electronic and information technology (EIT) products are covered by Section 508 of the Rehabilitation Act; and resources for making sure your EIT products are compliant
Fault detection monitor circuit provides ''self-heal capability'' in electronic modules - A concept
NASA Technical Reports Server (NTRS)
Kennedy, J. J.
1970-01-01
Self-checking technique detects defective solid state modules used in electronic test and checkout instrumentation. A ten bit register provides failure monitor and indication for 1023 comparator circuits, and the automatic fault-isolation capability permits the electronic subsystems to be repaired by replacing the defective module.
Huntley, Selene J; Dean, Rachel S; Massey, Andrew; Brennan, Marnie L
2016-01-01
Veterinarians are encouraged to use evidence to inform their practice, but it is unknown what resources (e.g. journals, electronic sources) are accessed by them globally. Understanding the key places veterinarians seek information can inform where new clinically relevant evidence should most effectively be placed. An international survey was conducted to gain understanding of how veterinary information is accessed by veterinarians worldwide. There were 2137 useable responses to the questionnaire from veterinarians in 78 countries. The majority of respondents (n = 1835/2137, 85.9%) undertook clinical work and worked in a high income country (n = 1576/1762, 89.4%). Respondents heard about the survey via national veterinary organisations or regulatory bodies (31.5%), online veterinary forums and websites (22.7%), regional, discipline-based or international veterinary organisations (22.7%) or by direct invitation from the researchers or via friends, colleagues or social media (7.6%). Clinicians and non-clinicians reportedly used journals most commonly (65.8%, n = 1207/1835; 75.6%, n = 216/286) followed by electronic resources (58.7%, n = 1077/1835; 55.9%, n = 160/286), respectively. Respondents listed a total of 518 journals and 567 electronic sources that they read. Differences in veterinarian preference for resources in developed, and developing countries, were found. The nominated journals most read were the Journal of the American Veterinary Medical Association (12.7% of nominations) for clinicians and the Veterinary Record (5.7%) for non-clinicians. The most accessed electronic resource reported was the Veterinary Information Network (25.6%) for clinicians and PubMed (7.4%) for non-clinicians. In conclusion, a wide array of journals and electronic resources appear to be accessed by veterinarians worldwide. Veterinary organisations appear to play an important role in global communication and outreach to veterinarians and consideration should be given to how these channels could be best utilised for effective dissemination of key research findings.
Huntley, Selene J.; Dean, Rachel S.; Massey, Andrew
2016-01-01
Veterinarians are encouraged to use evidence to inform their practice, but it is unknown what resources (e.g. journals, electronic sources) are accessed by them globally. Understanding the key places veterinarians seek information can inform where new clinically relevant evidence should most effectively be placed. An international survey was conducted to gain understanding of how veterinary information is accessed by veterinarians worldwide. There were 2137 useable responses to the questionnaire from veterinarians in 78 countries. The majority of respondents (n = 1835/2137, 85.9%) undertook clinical work and worked in a high income country (n = 1576/1762, 89.4%). Respondents heard about the survey via national veterinary organisations or regulatory bodies (31.5%), online veterinary forums and websites (22.7%), regional, discipline-based or international veterinary organisations (22.7%) or by direct invitation from the researchers or via friends, colleagues or social media (7.6%). Clinicians and non-clinicians reportedly used journals most commonly (65.8%, n = 1207/1835; 75.6%, n = 216/286) followed by electronic resources (58.7%, n = 1077/1835; 55.9%, n = 160/286), respectively. Respondents listed a total of 518 journals and 567 electronic sources that they read. Differences in veterinarian preference for resources in developed, and developing countries, were found. The nominated journals most read were the Journal of the American Veterinary Medical Association (12.7% of nominations) for clinicians and the Veterinary Record (5.7%) for non-clinicians. The most accessed electronic resource reported was the Veterinary Information Network (25.6%) for clinicians and PubMed (7.4%) for non-clinicians. In conclusion, a wide array of journals and electronic resources appear to be accessed by veterinarians worldwide. Veterinary organisations appear to play an important role in global communication and outreach to veterinarians and consideration should be given to how these channels could be best utilised for effective dissemination of key research findings. PMID:27458724
Detecting Lyme disease using antibody-functionalized carbon nanotubes
NASA Astrophysics Data System (ADS)
Dailey, Jennifer; Lerner, Mitchell; Goldsmith, Brett; Brisson, Dustin; Johnson, A. T. Charlie
2011-03-01
We combine antibodies for Lyme flagellar protein with carbon nanotube transistors to create an electronic sensor capable of definitive detection of Lyme disease. Over 35,000 cases of Lyme disease are reported in the United States each year, of which more than 23 percent are originally misdiagnosed. Rational design of the coupling of the biological system to the electronic system gives us a flexible sensor platform which we can apply to several biological systems. By coupling these antibodies to carbon nanotubes in particular, we allow for fast, sensitive, highly selective, electronic detection. Unlike antibody or biomarker detection, bacterial protein detection leads to positive identification of both early and late stage bacterial infections, and is easily expandable to environmental monitoring.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jothikumar, N., E-mail: jin2@cdc.gov; Hill, Vincent R.
Highlights: •Uses a single-labeled fluorescent primer for real-time PCR. •The detection sensitivity of PET PCR was comparable to TaqMan PCR. •Melt curve analysis can be performed to confirm target amplicon production. •Conventional PCR primers can be converted to PET PCR primers. -- Abstract: We report the development of a fluorescently labeled oligonucleotide primer that can be used to monitor real-time PCR. The primer has two parts, the 3′-end of the primer is complimentary to the target and a universal 17-mer stem loop at the 5′-end forms a hairpin structure. A fluorescent dye is attached to 5′-end of either the forwardmore » or reverse primer. The presence of guanosine residues at the first and second position of the 3′ dangling end effectively quenches the fluorescence due to the photo electron transfer (PET) mechanism. During the synthesis of nucleic acid, the hairpin structure is linearized and the fluorescence of the incorporated primer increases several-fold due to release of the fluorescently labeled tail and the absence of guanosine quenching. As amplicons are synthesized during nucleic acid amplification, the fluorescence increase in the reaction mixture can be measured with commercially available real-time PCR instruments. In addition, a melting procedure can be performed to denature the double-stranded amplicons, thereby generating fluorescence peaks that can differentiate primer dimers and other non-specific amplicons if formed during the reaction. We demonstrated the application of PET-PCR for the rapid detection and quantification of Cryptosporidium parvum DNA. Comparison with a previously published TaqMan® assay demonstrated that the two real-time PCR assays exhibited similar sensitivity for a dynamic range of detection of 6000–0.6 oocysts per reaction. PET PCR primers are simple to design and less-expensive than dual-labeled probe PCR methods, and should be of interest for use by laboratories operating in resource-limited environments.« less
Rapid Waterborne Pathogen Detection with Mobile Electronics.
Wu, Tsung-Feng; Chen, Yu-Chen; Wang, Wei-Chung; Kucknoor, Ashwini S; Lin, Che-Jen; Lo, Yu-Hwa; Yao, Chun-Wei; Lian, Ian
2017-06-09
Pathogen detection in water samples, without complex and time consuming procedures such as fluorescent-labeling or culture-based incubation, is essential to public safety. We propose an immunoagglutination-based protocol together with the microfluidic device to quantify pathogen levels directly from water samples. Utilizing ubiquitous complementary metal-oxide-semiconductor (CMOS) imagers from mobile electronics, a low-cost and one-step reaction detection protocol is developed to enable field detection for waterborne pathogens. 10 mL of pathogen-containing water samples was processed using the developed protocol including filtration enrichment, immune-reaction detection and imaging processing. The limit of detection of 10 E. coli O157:H7 cells/10 mL has been demonstrated within 10 min of turnaround time. The protocol can readily be integrated into a mobile electronics such as smartphones for rapid and reproducible field detection of waterborne pathogens.
Colleges Fight Fire With Electronics.
ERIC Educational Resources Information Center
College & University Business, 1968
1968-01-01
Description of various electronic fire detection and alarm systems is presented. Explanation of detective systems includes--(1) fixed-temperature and rate-of-rise heat sensitive devices, (2) smoke detective devices, (3) ionization systems, and (4) infrared and ultraviolet radiation devices. Each system type is evaluated in terms of operation,…
Virtual Resources Centers and Their Role in Small Rural Schools.
ERIC Educational Resources Information Center
Freitas, Candido Varela de; Silva, Antonio Pedro da
Virtual resources centers have been considered a pedagogical tool since the increasing development of electronic means allowed for the storage of huge amounts of information and its easy retrieval. Bearing in mind the need for enhancing the appearance of those centers, a discipline of "Management of Resources Centers" was included in a…
Counting on COUNTER: The Current State of E-Resource Usage Data in Libraries
ERIC Educational Resources Information Center
Welker, Josh
2012-01-01
Any librarian who has managed electronic resources has experienced the--for want of words--"joy" of gathering and analyzing usage statistics. Such statistics are important for evaluating the effectiveness of resources and for making important budgeting decisions. Unfortunately, the data are usually tedious to collect, inconsistently organized, of…
ERIC Educational Resources Information Center
Henninger, Jessamyn; Aber, Susan Ward
2010-01-01
Systems Architects and Information Technology administrators working in higher education help faculty, staff, and student computer users. Yet, who helps them? What resources do these professionals value? A case study was conducted using purposeful sampling and data collection through electronic interview to gather the preferred information-seeking…
Accessibility and Integrity of Networked Information Collections. Background Paper.
ERIC Educational Resources Information Center
Lynch, Clifford A.
This paper considers questions related to the integrity and accessibility of new electronic information resources. It begins with a review of recent developments in networked information resources and the tools to identify, navigate, and use such resources. An overview is then given of the issues involved in access and integrity questions. Links…
Electronic Theses and Dissertations: Promoting "Hidden" Research
ERIC Educational Resources Information Center
Copeland, Susan
2008-01-01
Since the mid 1990s an increasing number of higher education institutions and organisations have been encouraging the production and submission of theses and dissertations in electronic format. Where access to electronic theses and dissertations is available via the Internet, usage figures indicate that this is a much consulted resource. However,…
Raising the Standard. Electronics Technician Skills for Today and Tomorrow.
ERIC Educational Resources Information Center
Electronic Industries Foundation, Washington, DC.
This manual identifies the standard skills required of a work-ready, entry-level electronics technician. It provides a valuable resource for these groups: students considering careers as electronics technicians; for counselors, educators, and administrators; and for employers. An introduction discusses use of the standards and includes two lists…
Electronic Media: A Motif for Shared Resources.
ERIC Educational Resources Information Center
Lightner, Stanley L.; Johnson, W. C.
2000-01-01
A survey of trade and industrial education supervisors from 10 states determined the degree of use of electronic education methods. Instructors in these states used presentation software and web-based exercises most often; fewer used video, CD-ROM, and distance technologies; 70% had been taught electronic presentation methods in preservice or…
Federal Register 2010, 2011, 2012, 2013, 2014
2012-11-07
... technology, to include computer telecommunications or other electronic means, that the lead agency is... assess the capacity and resources of the public to utilize and maintain an electronic- or computer... the technology, to include computer telecommunications or other electronic means, that the lead agency...
Electronic Advocacy and Social Welfare Policy Education
ERIC Educational Resources Information Center
Moon, Sung Seek; DeWeaver, Kevin L.
2005-01-01
The rapid increase in the number of low-cost computers, the proliferation of user-friendly software, and the development of electronic networks have created the "informatics era." The Internet is a rapidly growing communication resource that is becoming mainstream in the American society. Computer-based electronic political advocacy by social…
ARL Supplementary Statistics, 2007-2008
ERIC Educational Resources Information Center
Bland, Les, Comp.; Kyrillidou, Martha, Comp.
2009-01-01
This report presents statistics on how Association of Research Libraries (ARL) member libraries spend money on electronic resources. This report indicates that 109 ARL libraries purchased 32,329,187 electronic books. In 2007-2008, there was a median of 28,319 acquisitions of electronic books by ARL libraries (this includes one institution that…
ARL Supplementary Statistics, 2006-2007
ERIC Educational Resources Information Center
Bland, Les, Comp.; Kyrillidou, Martha, Comp.
2009-01-01
This report presents statistics on how Association of Research Libraries (ARL) member libraries spend money on electronic resources. This report indicates that 108 ARL libraries purchased 25,006,758 electronic books. In 2006-2007, there was an ARL median of 243,725 acquisitions of electronic books (this includes one institution that purchased…
NASA Astrophysics Data System (ADS)
Kidera, Masanori; Seto, Yasuo; Takahashi, Kazuya; Enomoto, Shuichi; Kishi, Shintaro; Makita, Mika; Nagamatsu, Tsuyoshi; Tanaka, Tatsuhiko; Toda, Masayoshi
2011-03-01
We developed a detection technology for vapor forms of chemical warfare agents (CWAs) with an element analysis system using an electron cyclotron resonance ion source. After the vapor sample was introduced directly into the ion source, the molecular material was decomposed into elements using electron cyclotron resonance plasma and ionized. The following CWAs and stimulants were examined: diisopropyl fluorophosphonate (DFP), 2-chloroethylethylsulfide (2CEES), cyanogen chloride (CNCl), and hydrogen cyanide (HCN). The type of chemical warfare agents, specifically, whether it was a nerve agent, blister agent, blood agent, or choking agent, could be determined by measuring the quantities of the monatomic ions or CN + using mass spectrometry. It was possible to detect gaseous CWAs that could not be detected by a conventional mass spectrometer. The distribution of electron temperature in the plasma could be closely controlled by adjusting the input power of the microwaves used to generate the electron cyclotron resonance plasma, and the target compounds could be detected as molecular ions or fragment ions, enabling identification of the target agents.
Retrocausation acting in the single-electron double-slit interference experiment
NASA Astrophysics Data System (ADS)
Hokkyo, Noboru
The single electron double-slit interference experiment is given a time-symmetric interpretation and visualization in terms of the intermediate amplitude of transition between the particle source and the detection point. It is seen that the retarded (causal) amplitude of the electron wave expanding from the source shows an advanced (retrocausal) bifurcation and merging in passing through the double-slit and converges towards the detection point as if guided by the advanced (retrocausal) wave from the detected electron. An experiment is proposed to confirm the causation-retrocausation symmetry of the electron behavior by observing the insensitivity of the interference pattern to non-magnetic obstacles placed in the shadows of the retarded and advanced waves appearing on the rear and front sides of the double-slit.
Mediagraphy: Print and Nonprint Resources.
ERIC Educational Resources Information Center
Educational Media and Technology Yearbook, 1999
1999-01-01
Provides annotated listings for current journals, books, ERIC documents, articles, and nonprint resources in the following categories: artificial intelligence/robotics/electronic performance support systems; computer-assisted instruction; distance education; educational research; educational technology; information science and technology;…
The Dublin Core is a metadata element set intended to facilitate discovery of electronic resources. It was originally conceived for author-generated descriptions of Web resources, and the Dublin Core has attracted broad ranging international and interdisciplinary support. The cha...
Basdere, Bahadir; Seliger, Guenther
2003-12-01
Cycle economy as a paradigm for industry in the 21st century depends on the economical and ecological treatment of limited resources. The objective is to achieve more use with fewer resources to increase the use-productivity of these resources. The European Union, aware of the adverse environmental impacts associated with electrical and electronic consumer goods in particular, has passed legislation regulating their appropriate end-of-life treatment. Adaptation processes, including essential disassembly and re-assembly operations, contribute significantly toward the economical fulfillment of these new legal requirements. Typically, the disassembly of used products is characterized by a high rate of manual operations, wide variety of product types, and unknown product properties. To cope with such demands, life cycle units or product accompanying information systems, are being developed and used for acquiring data about a specific product throughout its life cycle to aid in determining the level of product deterioration. Modular disassembly processes and tools have been developed and realized to enable the handling of multiple productvariants. They are being implemented in prototypical hybrid disassembly systemsfor large- and small-size electrical and electronic consumer goods.
Comby, G.
1996-10-01
The Ceramic Electron Multipliers (CEM) is a compact, robust, linear and fast multi-channel electron multiplier. The Multi Layer Ceramic Technique (MLCT) allows to build metallic dynodes inside a compact ceramic block. The activation of the metallic dynodes enhances their secondary electron emission (SEE). The CEM can be used in multi-channel photomultipliers, multi-channel light intensifiers, ion detection, spectroscopy, analysis of time of flight events, particle detection or Cherenkov imaging detectors. (auth)
facility at Los Alamos: experiment E225. The main objective was to detect the scattering of electron detect the transmutation of C12 to N12 mediated by means of the electron-neutrino. This was also ;oscillate" to tau or, perhaps electron-type neutrinos on their way from Fermilab. MINOS was not
Federal Register 2010, 2011, 2012, 2013, 2014
2012-12-19
.../Electronic Equipment Bay Fire Detection and Smoke Penetration AGENCY: Federal Aviation Administration (FAA... where the flightcrew could determine the origin of smoke or fire by a straightforward airplane flight.... The FAA has no requirement for smoke and/or fire detection in the electrical/electronic equipment bays...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-04
...; Electrical/Electronic Equipment Bay Fire Detection and Smoke Penetration AGENCY: Federal Aviation... where the flight crew could determine the origin of smoke or fire by a straightforward airplane flight.... The FAA has no requirement for smoke and/or fire detection in the electrical/electronic equipment bays...
Effect of chemical compounds on electronic tongue response to citrus juices
USDA-ARS?s Scientific Manuscript database
The electronic tongue system mimics the process of taste detection by human taste buds and recognition by the brain, hence helping in prediction of taste. With this unique capability, the electronic tongue has been used for taste detection of a wide range of food products. As a preliminary step in p...
Habib, Komal; Parajuly, Keshav; Wenzel, Henrik
2015-10-20
Recovery of resources, in particular, metals, from waste flows is widely seen as a prioritized option to reduce their potential supply constraints in the future. The current waste electrical and electronic equipment (WEEE) treatment system is more focused on bulk metals, where the recycling rate of specialty metals, such as rare earths, is negligible compared to their increasing use in modern products, such as electronics. This study investigates the challenges in recovering these resources in the existing WEEE treatment system. It is illustrated by following the material flows of resources in a conventional WEEE treatment plant in Denmark. Computer hard disk drives (HDDs) containing neodymium-iron-boron (NdFeB) magnets were selected as the case product for this experiment. The resulting output fractions were tracked until their final treatment in order to estimate the recovery potential of rare earth elements (REEs) and other resources contained in HDDs. The results further show that out of the 244 kg of HDDs treated, 212 kg comprising mainly of aluminum and steel can be finally recovered from the metallurgic process. The results further demonstrate the complete loss of REEs in the existing shredding-based WEEE treatment processes. Dismantling and separate processing of NdFeB magnets from their end-use products can be a more preferred option over shredding. However, it remains a technological and logistic challenge for the existing system.
Development of a secondary electron energy analyzer for a transmission electron microscope.
Magara, Hideyuki; Tomita, Takeshi; Kondo, Yukihito; Sato, Takafumi; Akase, Zentaro; Shindo, Daisuke
2018-04-01
A secondary electron (SE) energy analyzer was developed for a transmission electron microscope. The analyzer comprises a microchannel plate (MCP) for detecting electrons, a coil for collecting SEs emitted from the specimen, a tube for reducing the number of backscattered electrons incident on the MCP, and a retarding mesh for selecting the energy of SEs incident on the MCP. The detection of the SEs associated with charging phenomena around a charged specimen was attempted by performing electron holography and SE spectroscopy using the energy analyzer. The results suggest that it is possible to obtain the energy spectra of SEs using the analyzer and the charging states of a specimen by electron holography simultaneously.
Roudsari, AV; Gordon, C; Gray, JA Muir
2001-01-01
Background In 1998, the U.K. National Health Service Information for Health Strategy proposed the implementation of a National electronic Library for Health to provide clinicians, healthcare managers and planners, patients and the public with easy, round the clock access to high quality, up-to-date electronic information on health and healthcare. The Virtual Branch Libraries are among the most important components of the National electronic Library for Health . They aim at creating online knowledge based communities, each concerned with some specific clinical and other health-related topics. Objectives This study is about the envisaged Dermatology Virtual Branch Libraries of the National electronic Library for Health . It aims at selecting suitable dermatology Web resources for inclusion in the forthcoming Virtual Branch Libraries after establishing preliminary quality benchmarking rules for this task. Psoriasis, being a common dermatological condition, has been chosen as a starting point. Methods Because quality is a principal concern of the National electronic Library for Health, the study includes a review of the major quality benchmarking systems available today for assessing health-related Web sites. The methodology of developing a quality benchmarking system has been also reviewed. Aided by metasearch Web tools, candidate resources were hand-selected in light of the reviewed benchmarking systems and specific criteria set by the authors. Results Over 90 professional and patient-oriented Web resources on psoriasis and dermatology in general are suggested for inclusion in the forthcoming Dermatology Virtual Branch Libraries. The idea of an all-in knowledge-hallmarking instrument for the National electronic Library for Health is also proposed based on the reviewed quality benchmarking systems. Conclusions Skilled, methodical, organized human reviewing, selection and filtering based on well-defined quality appraisal criteria seems likely to be the key ingredient in the envisaged National electronic Library for Health service. Furthermore, by promoting the application of agreed quality guidelines and codes of ethics by all health information providers and not just within the National electronic Library for Health, the overall quality of the Web will improve with time and the Web will ultimately become a reliable and integral part of the care space. PMID:11720947
Swallowable fluorometric capsule for wireless triage of gastrointestinal bleeding.
Nemiroski, A; Ryou, M; Thompson, C C; Westervelt, R M
2015-12-07
Real-time detection of gastrointestinal bleeding remains a major challenge because there does not yet exist a minimally invasive technology that can both i) monitor for blood from an active hemorrhage and ii) uniquely distinguish it from blood left over from an inactive hemorrhage. Such a device would be an important tool for clinical triage. One promising solution, which we have proposed previously, is to inject a fluorescent dye into the blood stream and to use it as a distinctive marker of active bleeding by monitoring leakage into the gastrointestinal tract with a wireless fluorometer. This paper reports, for the first time to our knowledge, the development of a swallowable, wireless capsule with a built-in fluorometer capable of detecting fluorescein in blood, and intended for monitoring gastrointestinal bleeding in the stomach. The embedded, compact fluorometer uses pinholes to define a microliter sensing volume and to eliminate bulky optical components. The proof-of-concept capsule integrates optics, low-noise analog sensing electronics, a microcontroller, battery, and low power Zigbee radio, all into a cylindrical package measuring 11 mm × 27 mm and weighing 10 g. Bench-top experiments demonstrate wireless fluorometry with a limit-of-detection of 20 nM aqueous fluorescein. This device represents a major step towards a technology that would enable simple, rapid detection of active gastrointestinal bleeding, a capability that would save precious time and resources and, ultimately, reduce complications in patients.
Zlamparet, Gabriel I; Tan, Quanyin; Stevels, A B; Li, Jinhui
2018-03-01
This comparative research represents an example for a better conservation of resources by reducing the amount of waste (kg) and providing it more value under the umbrella of remanufacturing. The three discussed cases will expose three issues already addressed separately in the literature. The generation of waste electrical and electronic equipment (WEEE) interacts with the environmental depletion. In this article, we gave the examples of addressed issues under the concept of remanufacturing. Online collection opportunity eliminating classical collection, a business to business (B2B) implementation for remanufactured servers and medical devices. The material reuse (recycling), component sustainability, reuse (part harvesting), product reuse (after repair/remanufacturing) indicates the recovery potential using remanufacturing tool for a better conservation of resources adding more value to the products. Our findings can provide an overview of new system organization for the general collection, market potential and the technological advantages using remanufacturing instead of recycling of WEEE or used electrical and electronic equipment. Copyright © 2017. Published by Elsevier Ltd.
Levine, Peter M; Gong, Ping; Levicky, Rastislav; Shepard, Kenneth L
2009-03-15
Optical biosensing based on fluorescence detection has arguably become the standard technique for quantifying extents of hybridization between surface-immobilized probes and fluorophore-labeled analyte targets in DNA microarrays. However, electrochemical detection techniques are emerging which could eliminate the need for physically bulky optical instrumentation, enabling the design of portable devices for point-of-care applications. Unlike fluorescence detection, which can function well using a passive substrate (one without integrated electronics), multiplexed electrochemical detection requires an electronically active substrate to analyze each array site and benefits from the addition of integrated electronic instrumentation to further reduce platform size and eliminate the electromagnetic interference that can result from bringing non-amplified signals off chip. We report on an active electrochemical biosensor array, constructed with a standard complementary metal-oxide-semiconductor (CMOS) technology, to perform quantitative DNA hybridization detection on chip using targets conjugated with ferrocene redox labels. A 4 x 4 array of gold working electrodes and integrated potentiostat electronics, consisting of control amplifiers and current-input analog-to-digital converters, on a custom-designed 5 mm x 3 mm CMOS chip drive redox reactions using cyclic voltammetry, sense DNA binding, and transmit digital data off chip for analysis. We demonstrate multiplexed and specific detection of DNA targets as well as real-time monitoring of hybridization, a task that is difficult, if not impossible, with traditional fluorescence-based microarrays.
Social Studies Online Resources. Media Corner.
ERIC Educational Resources Information Center
Wilson, Jeri, Ed.
1995-01-01
Maintains that three types of social studies activities are found on the information highway: (1) electronic mail; (2) information; and (3) conferencing. Describes examples of each. Discusses commercial services and resource materials and provides references to online services. (CFR)
Mediagraphy: Print and Nonprint Resources.
ERIC Educational Resources Information Center
Educational Media and Technology Yearbook, 1996
1996-01-01
This annotated list includes media-related resources classified under the following headings: artificial intelligence and robotics, CD-ROM, computer-assisted instruction, databases and online searching, distance education, educational research, educational technology, electronic publishing, information science and technology, instructional design…
Mediagraphy: Print and Nonprint Resources.
ERIC Educational Resources Information Center
Educational Media and Technology Yearbook, 1997
1997-01-01
This annotated list includes media-related resources classified under the following headings: artificial intelligence and robotics, CD-ROM, computer-assisted instruction, databases and online searching, distance education, educational research, educational technology, electronic publishing, information science and technology, instructional design…
Molecular gated-AlGaN/GaN high electron mobility transistor for pH detection.
Ding, Xiangzhen; Yang, Shuai; Miao, Bin; Gu, Le; Gu, Zhiqi; Zhang, Jian; Wu, Baojun; Wang, Hong; Wu, Dongmin; Li, Jiadong
2018-04-18
A molecular gated-AlGaN/GaN high electron mobility transistor has been developed for pH detection. The sensing surface of the sensor was modified with 3-aminopropyltriethoxysilane to provide amphoteric amine groups, which would play the role of receptors for pH detection. On modification with 3-aminopropyltriethoxysilane, the transistor exhibits good chemical stability in hydrochloric acid solution and is sensitive for pH detection. Thus, our molecular gated-AlGaN/GaN high electron mobility transistor acheived good electrical performances such as chemical stability (remained stable in hydrochloric acid solution), good sensitivity (37.17 μA/pH) and low hysteresis. The results indicate a promising future for high-quality sensors for pH detection.
Critical Infrastructure References: Documented Literature Search
2012-10-01
the literature search document can be a resource for DRDC and external partners. Future plans: At present, the electronic copies of the reference...Personal Information Protection and Electronic Documents Act (S.C. 2000, c. 5) Title: Personal Information Protection and Electronic Documents Act (S.C...2011 Overview: • "An Act to support and promote electronic commerce by protecting personal information that is collected, used or disclosed in
Evaluation of an Android-based mHealth system for population surveillance in developing countries
Mbugua, Samuel; Amadi, David; Chepnǵeno, Viola; Saleem, Jason J; Anokwa, Yaw; Hartung, Carl; Borriello, Gaetano; Mamlin, Burke W; Ndege, Samson K; Were, Martin C
2012-01-01
Objective In parts of the developing world traditionally modeled healthcare systems do not adequately meet the needs of the populace. This can be due to imbalances in both supply and demand—there may be a lack of sufficient healthcare and the population most at need may be unable or unwilling to take advantage of it. Home-based care has emerged as a possible mechanism to bring healthcare to the populace in a cost-effective, useful manner. This study describes the development, implementation, and evaluation of a mobile device-based system to support such services. Materials and Methods Mobile phones were utilized and a structured survey was implemented to be administered by community health workers using Open Data Kit. This system was used to support screening efforts for a population of two million persons in western Kenya. Results Users of the system felt it was easy to use and facilitated their work. The system was also more cost effective than pen and paper alternatives. Discussion This implementation is one of the largest applications of a system utilizing handheld devices for performing clinical care during home visits in a resource-constrained environment. Because the data were immediately available electronically, initial reports could be performed and important trends in data could thus be detected. This allowed adjustments to the programme to be made sooner than might have otherwise been possible. Conclusion A viable, cost-effective solution at scale has been developed and implemented for collecting electronic data during household visits in a resource-constrained setting. PMID:22366295
Roth, Gary A; Sosa Peña, Maria del Pilar; Neu-Baker, Nicole M; Tahiliani, Sahil; Brenner, Sara A
2015-12-08
Nanomaterials are increasingly prevalent throughout industry, manufacturing, and biomedical research. The need for tools and techniques that aid in the identification, localization, and characterization of nanoscale materials in biological samples is on the rise. Currently available methods, such as electron microscopy, tend to be resource-intensive, making their use prohibitive for much of the research community. Enhanced darkfield microscopy complemented with a hyperspectral imaging system may provide a solution to this bottleneck by enabling rapid and less expensive characterization of nanoparticles in histological samples. This method allows for high-contrast nanoscale imaging as well as nanomaterial identification. For this technique, histological tissue samples are prepared as they would be for light-based microscopy. First, positive control samples are analyzed to generate the reference spectra that will enable the detection of a material of interest in the sample. Negative controls without the material of interest are also analyzed in order to improve specificity (reduce false positives). Samples can then be imaged and analyzed using methods and software for hyperspectral microscopy or matched against these reference spectra in order to provide maps of the location of materials of interest in a sample. The technique is particularly well-suited for materials with highly unique reflectance spectra, such as noble metals, but is also applicable to other materials, such as semi-metallic oxides. This technique provides information that is difficult to acquire from histological samples without the use of electron microscopy techniques, which may provide higher sensitivity and resolution, but are vastly more resource-intensive and time-consuming than light microscopy.
Open Education Resources and Mobile Technology to Narrow the Learning Divide
ERIC Educational Resources Information Center
Ally, Mohamed; Samaka, Mohammed
2013-01-01
As the world becomes more digitized, there will be an increasing need to make available learning resources in electronic format for access by information and communication technologies. The question education will face is whether these learning resources will be available for learners to access at no cost or affordable cost so that there will be…
E-Resource Statistics: What to Do when You Have No Money
ERIC Educational Resources Information Center
Walker, Mary
2009-01-01
Libraries are moving toward electronic resource management systems (ERMSs) to track their usage statistics, but these can be expensive to purchase and maintain. For some libraries, an ERMS can be cost-prohibitive, but they still need to justify the renewal of databases and e-journals to their budget officers or determine which e-resources should…
Botulinum toxin detection using AlGaN /GaN high electron mobility transistors
NASA Astrophysics Data System (ADS)
Wang, Yu-Lin; Chu, B. H.; Chen, K. H.; Chang, C. Y.; Lele, T. P.; Tseng, Y.; Pearton, S. J.; Ramage, J.; Hooten, D.; Dabiran, A.; Chow, P. P.; Ren, F.
2008-12-01
Antibody-functionalized, Au-gated AlGaN /GaN high electron mobility transistors (HEMTs) were used to detect botulinum toxin. The antibody was anchored to the gate area through immobilized thioglycolic acid. The AlGaN /GaN HEMT drain-source current showed a rapid response of less than 5s when the target toxin in a buffer was added to the antibody-immobilized surface. We could detect a range of concentrations from 1to10ng/ml. These results clearly demonstrate the promise of field-deployable electronic biological sensors based on AlGaN /GaN HEMTs for botulinum toxin detection.
Searching for TeV cosmic electrons with the CREST experiment
NASA Astrophysics Data System (ADS)
Coutu, S.; Anderson, T.; Bower, C.; Gennaro, J.; Geske, M.; Müller, D.; Musser, J.; Nutter, S.; Park, N. H.; Schubnell, M.; Tarlé, G.; Wakely, S.; Yagi, A.
2011-06-01
The Cosmic Ray Electron Synchrotron Telescope (CREST) high-altitude balloon experiment is a pathfinding effort to detect for the first time multi-TeV cosmic-ray electrons. Such would be the markers of nearby cosmic accelerators, as energetic electrons from distant Galactic sources are expected to be depleted by radiative losses during interstellar transport. Electrons will be detected indirectly by the characteristic signature of their geomagnetic synchrotron losses, in the form of a burst of coaligned x-ray photons intersecting the plane of the instrument. Since the primary electron itself need not traverse the payload, an effective detection area is achieved that is several times the nominal 6.4 m2 instrument. The payload is composed of an array of 1024 BaF2 crystals surrounded by a set of veto scintillator detectors. A long-duration balloon flight in Antarctica is planned for the 2011-12 season.
Photon Counting Imaging with an Electron-Bombarded Pixel Image Sensor
Hirvonen, Liisa M.; Suhling, Klaus
2016-01-01
Electron-bombarded pixel image sensors, where a single photoelectron is accelerated directly into a CCD or CMOS sensor, allow wide-field imaging at extremely low light levels as they are sensitive enough to detect single photons. This technology allows the detection of up to hundreds or thousands of photon events per frame, depending on the sensor size, and photon event centroiding can be employed to recover resolution lost in the detection process. Unlike photon events from electron-multiplying sensors, the photon events from electron-bombarded sensors have a narrow, acceleration-voltage-dependent pulse height distribution. Thus a gain voltage sweep during exposure in an electron-bombarded sensor could allow photon arrival time determination from the pulse height with sub-frame exposure time resolution. We give a brief overview of our work with electron-bombarded pixel image sensor technology and recent developments in this field for single photon counting imaging, and examples of some applications. PMID:27136556
NASA Astrophysics Data System (ADS)
Kerbiriou, X.; Barthe, M.-F.; Esnouf, S.; Desgardin, P.; Blondiaux, G.; Petite, G.
2007-05-01
Both for electronic and nuclear applications, it is of major interest to understand the properties of point defects into silicon carbide (SiC). Low energy electron irradiations are supposed to create primary defects into materials. SiC single crystals have been irradiated with electrons at two beam energies in order to investigate the silicon displacement threshold energy into SiC. This paper presents the characterization of the electron irradiation-induced point defects into both polytypes hexagonal (6H) and cubic (3C) SiC single crystals by using both positron annihilation spectroscopy (PAS) and electron paramagnetic resonance (EPR). The nature and the concentration of the generated point defects depend on the energy of the electron beam and the polytype. After an electron irradiation at an energy of 800 keV vSi mono-vacancies and vSi-vC di-vacancies are detected in both 3C and 6H-SiC polytypes. On the contrary, the nature of point defects detected after an electron irradiation at 190 keV strongly depends on the polytype. Into 6H-SiC crystals, silicon Frenkel pairs vSi-Si are detected whereas only carbon vacancy related defects are detected into 3C-SiC crystals. The difference observed in the distribution of defects detected into the two polytypes can be explained by the different values of the silicon displacement threshold energies for 3C and 6H-SiC. By comparing the calculated theoretical numbers of displaced atoms with the defects numbers measured using EPR, the silicon displacement threshold energy has been estimated to be slightly lower than 20 eV in the 6H polytype and close to 25 eV in the 3C polytype.
ERIC Educational Resources Information Center
Library of Congress, Washington, DC.
The Library of Congress hosted a 1-day conference, "Delivering Electronic Information in a Knowledge-Based Democracy" to explore the public policy framework essential to creating electronic information resources and making them broadly available. Participants from a variety of sectors contributed to wide-ranging discussions on issues…
Electronic Publishing in Academia: An Economic Perspective.
ERIC Educational Resources Information Center
Getz, Malcolm
The challenge to academia is to invest in services that will turn the abundance of electronic data into sound, useful, compelling information products. The process of filtering, labeling, refining, and packaging, that is, the process of editing and publishing, takes resources and will be shaped by the electronic world in significant ways. This…
Robert Hofstadter, Electron Scattering, the Structure of the Nucleons, and
, Electron Scattering, the Structure of the Nucleons, and Scintillation Counters Resources with Additional -point particles and therefore possessed structure. For this work Hofstadter was awarded the Nobel Prize structure of the nucleons, and scintillation counters is available in electronic documents and on the Web
Module One: Electrical Current; Basic Electricity and Electronics Individualized Learning System.
ERIC Educational Resources Information Center
Bureau of Naval Personnel, Washington, DC.
The student is introduced in this module to some fundamental concepts of electricity. The module is divided into five lessons: electricity and the electron, electron movement, current flow, measurement of current, and the ammeter. Each lesson consists of an overview, a list of study resources, lesson narratives, programed materials, and lesson…
The Influence of Electronic Dictionaries on Vocabulary Knowledge Extension
ERIC Educational Resources Information Center
Rezaei, Mojtaba; Davoudi, Mohammad
2016-01-01
Vocabulary learning needs special strategies in language learning process. The use of dictionaries is a great help in vocabulary learning and nowadays the emergence of electronic dictionaries has added a new and valuable resource for vocabulary learning. The present study aims to explore the influence of Electronic Dictionaries (ED) Vs. Paper…
ERIC Educational Resources Information Center
Weingart, Sandra J.; Anderson, Janet A.
2000-01-01
Describes a study conducted at the Utah State University library that investigated electronic database awareness and use by 856 administrators and teaching faculty. Responses to a survey revealed the need for greater publicity regarding new electronic acquisitions, training opportunities, and methods of remote access. (Author/LRW)
Probing the magnetsophere with artificial electron beams
NASA Technical Reports Server (NTRS)
Winckler, J. R.
1981-01-01
An analysis is conducted of the University of Minnesota Electron Echo experiments, which so far have included five sounding rocket experiments. The concept of the Echo experiment is to inject electron beam pulses from a rocket into the ionosphere at altitudes in the range from 100 to 300 km. The electrons move to the conjugate hemisphere following magnetic field lines and return on neighboring field lines to the neighborhood of the rocket where the pulses may be detected and analyzed. Attention is given to the detection and analysis of echoes, the structure of echoes, and the Echo V experiment. The Echo V experiment showed clearly that detection of remote echo beams by atmospheric fluorescence using low light level TV system is not a viable technique. A future experiment is to use throw-away detectors for direct remote echo detection.
NASA Astrophysics Data System (ADS)
Katz, Itai; Fehr, Matthias; Schnegg, Alexander; Lips, Klaus; Blank, Aharon
2015-02-01
The in-operando detection and high resolution spatial imaging of paramagnetic defects, impurities, and states becomes increasingly important for understanding loss mechanisms in solid-state electronic devices. Electron spin resonance (ESR), commonly employed for observing these species, cannot meet this challenge since it suffers from limited sensitivity and spatial resolution. An alternative and much more sensitive method, called electrically-detected magnetic resonance (EDMR), detects the species through their magnetic fingerprint, which can be traced in the device's electrical current. However, until now it could not obtain high resolution images in operating electronic devices. In this work, the first spatially-resolved electrically-detected magnetic resonance images (EDMRI) of paramagnetic states in an operating real-world electronic device are provided. The presented method is based on a novel microwave pulse sequence allowing for the coherent electrical detection of spin echoes in combination with powerful pulsed magnetic-field gradients. The applicability of the method is demonstrated on a device-grade 1-μm-thick amorphous silicon (a-Si:H) solar cell and an identical device that was degraded locally by an electron beam. The degraded areas with increased concentrations of paramagnetic defects lead to a local increase in recombination that is mapped by EDMRI with ∼20-μm-scale pixel resolution. The novel approach presented here can be widely used in the nondestructive in-operando three-dimensional characterization of solid-state electronic devices with a resolution potential of less than 100 nm.
Resources for Radiation Test Data
NASA Technical Reports Server (NTRS)
O'Bryan, Martha V.; Casey, Megan C.; Lauenstein, Jean-Marie; LaBel, Ken
2016-01-01
The performance of electronic devices in a space radiation environment is often limited by susceptibility to single-event effects (SEE), total ionizing dose (TID), and displacement damage (DD). Interpreting the results of SEE, TID, and DD testing of complex devices is quite difficult given the rapidly changing nature of both technology and the related radiation issues. Radiation testing is performed to establish the sensitivities of candidate spacecraft electronics to single-event upset (SEU), single-event latchup (SEL), single-event gate rupture (SEGR), single-event burnout (SEB), single-event transients (SETs), TID, and DD effects. Knowing where to search for these test results is a valuable resource for the aerospace engineer or spacecraft design engineer. This poster is intended to be a resource tool for finding radiation test data.
Shebanova, A S; Bogdanov, A G; Ismagulova, T T; Feofanov, A V; Semenyuk, P I; Muronets, V I; Erokhina, M V; Onishchenko, G E; Kirpichnikov, M P; Shaitan, K V
2014-01-01
This work represents the results of the study on applicability of the modern methods of analytical transmission electron microscopy for detection, identification and visualization of localization of nanoparticles of titanium and cerium oxides in A549 cell, human lung adenocarcinoma cell line. A comparative analysis of images of the nanoparticles in the cells obtained in the bright field mode of transmission electron microscopy, under dark-field scanning transmission electron microscopy and high-angle annular dark field scanning transmission electron was performed. For identification of nanoparticles in the cells the analytical techniques, energy-dispersive X-ray spectroscopy and electron energy loss spectroscopy, were compared when used in the mode of obtaining energy spectrum from different particles and element mapping. It was shown that the method for electron tomography is applicable to confirm that nanoparticles are localized in the sample but not coated by contamination. The possibilities and fields of utilizing different techniques for analytical transmission electron microscopy for detection, visualization and identification of nanoparticles in the biological samples are discussed.
Shakeel, Sadia; Nesar, Shagufta; Rahim, Najia; Iffat, Wajiha; Ahmed, Hafiza Fouzia; Rizvi, Mehwish; Jamshed, Shazia
2017-01-01
Despite an increased popularity of print and electronic media applications, there is a paucity of data reflecting doctors' opinions regarding efficient utilization of these resources for the betterment of public health. Hence, this study aimed to investigate the perception of physicians toward the effect of electronic and print media on the health status of patients. The current research is a cross-sectional study conducted from January 2015 to July 2015. The study population comprised physicians rendering their services in different hospitals of Karachi, Pakistan, selected by the nonprobability convenience sampling technique. In this study, 500 questionnaires were distributed through email or direct correspondence. Physicians' perception toward the impact of electronic and print media on the health status of patients was assessed with a 20-item questionnaire. Different demographic characteristics, such as age, gender, institution, position, and experience of respondents, were recorded. Quantitative data were analyzed with the use of Statistical Package for Social Sciences, version 20.0 (SPSS, Chicago, IL). The association of the demographic characteristics of the responses of physicians was determined by one-way ANOVA using 0.05 level of significance. In this study, 254 physicians provided consent to show their responses for research purposes. A response rate of 50.8% was obtained. Nearly one-third of the respondents negated that patients get health benefit using electronic and print media. The majority did not consider electronic and print media as lifestyle-modifying factors. Physicians thought that patients particularly do not rely on mass media for acquiring health information and consider healthcare professionals as unswerving information resource. Mass media can be productive resources to augment awareness among patients, although physicians seem unconvinced about the extended usage of print/electronic media.
Shakeel, Sadia; Nesar, Shagufta; Rahim, Najia; Iffat, Wajiha; Ahmed, Hafiza Fouzia; Rizvi, Mehwish; Jamshed, Shazia
2017-01-01
Aims: Despite an increased popularity of print and electronic media applications, there is a paucity of data reflecting doctors’ opinions regarding efficient utilization of these resources for the betterment of public health. Hence, this study aimed to investigate the perception of physicians toward the effect of electronic and print media on the health status of patients. Setting and Design: The current research is a cross-sectional study conducted from January 2015 to July 2015. The study population comprised physicians rendering their services in different hospitals of Karachi, Pakistan, selected by the nonprobability convenience sampling technique. In this study, 500 questionnaires were distributed through email or direct correspondence. Methods and Materials: Physicians’ perception toward the impact of electronic and print media on the health status of patients was assessed with a 20-item questionnaire. Different demographic characteristics, such as age, gender, institution, position, and experience of respondents, were recorded. Quantitative data were analyzed with the use of Statistical Package for Social Sciences, version 20.0 (SPSS, Chicago, IL). The association of the demographic characteristics of the responses of physicians was determined by one-way ANOVA using 0.05 level of significance. Results: In this study, 254 physicians provided consent to show their responses for research purposes. A response rate of 50.8% was obtained. Nearly one-third of the respondents negated that patients get health benefit using electronic and print media. The majority did not consider electronic and print media as lifestyle-modifying factors. Physicians thought that patients particularly do not rely on mass media for acquiring health information and consider healthcare professionals as unswerving information resource. Conclusions: Mass media can be productive resources to augment awareness among patients, although physicians seem unconvinced about the extended usage of print/electronic media. PMID:29456378
ERIC Educational Resources Information Center
Khan, Badrul H.
2002-01-01
Considers factors that must be weighed in creating effective electronic learning environments and presents a basic framework for Web-based or electronic learning. Highlights include the institutional dimension; the pedagogical dimension; technological dimension; interface design; evaluation; management; resource support; and ethical…
NASA Technical Reports Server (NTRS)
Brusse, Jay
2000-01-01
The Active and Passive Supplier Assessment Programs (ASAP and PSAP) WWW Sites provide general information to the electronic parts community regarding the availability of electronic parts. They also provide information to NASA regarding modifications to commonly used procurement specifications and test methods. The ASAP and PSAP www sites are ongoing resources produced by Code 562 in support of the NASA HQ funded NASA Electronic Parts and Packaging (NEPP) Program. These WWW sites do not provide information pertaining to patented or proprietary information. All of the information contained in these www sites is available through various other public domain resources such as US Military Qualified Producers Listings (QPLs) and Qualified Manufacturer Listings (QMLs) and industry working groups such as the Electronics Industry Alliance (EIA) and the Space Parts Working Group (SPWG).
Yang, Guo Liang; Aziz, Aamer; Narayanaswami, Banukumar; Anand, Ananthasubramaniam; Lim, C C Tchoyoson; Nowinski, Wieslaw Lucjan
2005-01-01
A new method has been developed for multimedia enhancement of electronic teaching files created by using the standard protocols and formats offered by the Medical Imaging Resource Center (MIRC) project of the Radiological Society of North America. The typical MIRC electronic teaching file consists of static pages only; with the new method, audio and visual content may be added to the MIRC electronic teaching file so that the entire image interpretation process can be recorded for teaching purposes. With an efficient system for encoding the audiovisual record of on-screen manipulation of radiologic images, the multimedia teaching files generated are small enough to be transmitted via the Internet with acceptable resolution. Students may respond with the addition of new audio and visual content and thereby participate in a discussion about a particular case. MIRC electronic teaching files with multimedia enhancement have the potential to augment the effectiveness of diagnostic radiology teaching. RSNA, 2005.
Rosenthal, David A; Layman, Elizabeth J
2008-02-13
The United States Department of Health and Human Services (DHHS) has emphasized the importance of utilizing health information technologies, thus making the availability of electronic resources critical for physicians across the country. However, few empirical assessments exist regarding the current status of computerization and utilization of electronic resources in physician offices and physicians' perceptions of the advantages and disadvantages of computerization. Through a survey of physicians' utilization and perceptions of health information technology, this study found that a "digital divide" existed for eastern North Carolina physicians in smaller physician practices. The physicians in smaller practices were less likely to utilize or be interested in utilizing electronic health records, word processing applications, and the Internet.
Ryder, R E; Kong, N; Bates, A S; Sim, J; Welch, J; Kritzinger, E E
1998-03-01
Polaroid photography in diabetic retinopathy screening allows instant image availability to enhance the results of ophthalmoscopy. Retinal cameras are now being developed which use video/digital imaging techniques to produce an instant enlarged retinal image on a computer monitor screen. We aimed to compare one such electronic imaging system, attached to a Canon CR5 45NM, with standard Polaroid retinal photography. Two hundred and thirteen eyes from 107 diabetic patients were photographed through dilated pupils by both systems in random order and the images were analysed blind. Diabetic retinopathy was present in 58 eyes of which 55/58 (95%) were detected on the electronic image and only 49/58 (84%) on the Polaroid. Of 34 eyes requiring ophthalmologist referral according to standard European criteria, 34/34 (100%) were detected on the electronic image and only 24/34 (71%) on the Polaroid. Side by side comparisons showed electronic imaging to be superior to Polaroid at lesion detection. Using linear analogue scales, the patients assessed the electronic imaging photographic flash as less uncomfortable than the Polaroid equivalent (p < 0.0001). Other advantages of electronic imaging include: ready storage of the images with other patient clinical data on the diabetes computerized register/database; potential for image enhancement and analysis using image analysis software and electronic transfer of images to ophthalmologist or general practitioner. Electronic imaging systems represent a potential major advance for the improvement of diabetic retinopathy screening.
Robinson, Matthew L.; Manabe, Yukari C.
2017-01-01
Diagnosing the cause of acute febrile illness in resource-limited settings is important—to give the correct antimicrobials to patients who need them, to prevent unnecessary antimicrobial use, to detect emerging infectious diseases early, and to guide vaccine deployment. A variety of approaches are yielding more rapid and accurate tests that can detect more pathogens in a wider variety of settings. After decades of slow progress in diagnostics for acute febrile illness in resource-limited settings, a wave of converging advancements will enable clinicians in resource-limited settings to reduce uncertainty for the diagnosis of acute febrile illness. PMID:28719277
Ndeffo Mbah, Martial L.; Gilligan, Christopher A.
2010-01-01
Culling of infected individuals is a widely used measure for the control of several plant and animal pathogens but culling first requires detection of often cryptically-infected hosts. In this paper, we address the problem of how to allocate resources between detection and culling when the budget for disease management is limited. The results are generic but we motivate the problem for the control of a botanical epidemic in a natural ecosystem: sudden oak death in mixed evergreen forests in coastal California, in which species composition is generally dominated by a spreader species (bay laurel) and a second host species (coast live oak) that is an epidemiological dead-end in that it does not transmit infection but which is frequently a target for preservation. Using a combination of an epidemiological model for two host species with a common pathogen together with optimal control theory we address the problem of how to balance the allocation of resources for detection and epidemic control in order to preserve both host species in the ecosystem. Contrary to simple expectations our results show that an intermediate level of detection is optimal. Low levels of detection, characteristic of low effort expended on searching and detection of diseased trees, and high detection levels, exemplified by the deployment of large amounts of resources to identify diseased trees, fail to bring the epidemic under control. Importantly, we show that a slight change in the balance between the resources allocated to detection and those allocated to control may lead to drastic inefficiencies in control strategies. The results hold when quarantine is introduced to reduce the ingress of infected material into the region of interest. PMID:20856850
A. Dan Wilson; D.G. Lester; C.S. Oberle
2004-01-01
Conductive polymer analysis, a type of electronic aroma detection technology, was evaluated for its efficacy in the detection, identification, and discrimination of plant-pathogenic microorganisms on standardized media and in diseased plant tissues. The method is based on the acquisition of a diagnostic electronic fingerprint derived from multisensor responses to...
Make It and Take It: Computer-Based Resources for Lesson Planning.
ERIC Educational Resources Information Center
Brown, Tasha; Cargill, Debby; Hostetler, Jan; Joyner, Susan; Phillips, Vanessa
This document is part lesson planner and idea resource and part annotated bibliography of electronic resources. The lesson planner is divided into four parts. Part one, "Tables to Go," contains different tables that can be used for a variety of exercises at all levels of the English-as-a-Second-Language (ESL) classroom. Part two, "Exploring the…
Integrating Genomic Resources with Electronic Health Records using the HL7 Infobutton Standard
Overby, Casey Lynnette; Del Fiol, Guilherme; Rubinstein, Wendy S.; Maglott, Donna R.; Nelson, Tristan H.; Milosavljevic, Aleksandar; Martin, Christa L.; Goehringer, Scott R.; Freimuth, Robert R.; Williams, Marc S.
2016-01-01
Summary Background The Clinical Genome Resource (ClinGen) Electronic Health Record (EHR) Workgroup aims to integrate ClinGen resources with EHRs. A promising option to enable this integration is through the Health Level Seven (HL7) Infobutton Standard. EHR systems that are certified according to the US Meaningful Use program provide HL7-compliant infobutton capabilities, which can be leveraged to support clinical decision-making in genomics. Objectives To integrate genomic knowledge resources using the HL7 infobutton standard. Two tactics to achieve this objective were: (1) creating an HL7-compliant search interface for ClinGen, and (2) proposing guidance for genomic resources on achieving HL7 Infobutton standard accessibility and compliance. Methods We built a search interface utilizing OpenInfobutton, an open source reference implementation of the HL7 Infobutton standard. ClinGen resources were assessed for readiness towards HL7 compliance. Finally, based upon our experiences we provide recommendations for publishers seeking to achieve HL7 compliance. Results Eight genomic resources and two sub-resources were integrated with the ClinGen search engine via OpenInfobutton and the HL7 infobutton standard. Resources we assessed have varying levels of readiness towards HL7-compliance. Furthermore, we found that adoption of standard terminologies used by EHR systems is the main gap to achieve compliance. Conclusion Genomic resources can be integrated with EHR systems via the HL7 Infobutton standard using OpenInfobutton. Full compliance of genomic resources with the Infobutton standard would further enhance interoperability with EHR systems. PMID:27579472
Resources to Manage a Private Practice.
ERIC Educational Resources Information Center
Aigner, John; Cheek, Fredricka; Donati, Georgia; Zuravicky, Dori
1997-01-01
Includes four theme articles: "The Digital Toolkit: Electronic Necessities for Private Practice" (John Aigner); "Organizing a Private Practice: Forms, Fees, and Physical Set-up (Fredricka Cheek); "Career Development Resources: Guidelines for Setting Up a Private Practice Library" (Georgia Donati); and "Books to…
ERIC Educational Resources Information Center
Berson, Ilene R.; Berson, Michael J.; Desai, Shreya; Falls, Donald; Fenaughty, John
2008-01-01
A range of electronic resources, including video-based instruction, are used to promote cybersafety to young people at school. This evaluation analyzed seven distinct programs that use electronic media in Internet safety initiatives in schools. The findings highlight emerging evidence on successful approaches to engage children in assessing risky…
Browsing the Virtual Stacks: Making Electronic Reference Tools More Visible to Users
ERIC Educational Resources Information Center
Peterson, Elizabeth
2008-01-01
Electronic reference resources are expanding traditional print reference collections far beyond the walls of the library building. While the library literature has seen a debate rage about the various merits and pitfalls of electronic reference sources, no one disputes they are here to stay. As more of the library content becomes available through…
NASA Technical Reports Server (NTRS)
1982-01-01
Grace Industries, Inc.'s Electronic Nose is a vapor and gas detector, deriving from NASA's electronic circuitry, capable for sensing the presence of accelerants several days after a fire. The device is powered by rechargeable battery and no special training needed to operate. If an accelerant is present, device will emit a beeping sound and trigger a flashing light; the faster the beep rate, the more volatile the accelerant. Its sensitivity can also detect minute traces of accelerants. Unit saves investigators of fire causes time and expense by providing speedy detection of physical evidence for use in court. Device is also useful for detecting hazardous fumes, locating and detecting gas leaks in refineries and on oil drilling rigs.
Effect of electron irradiation dose on the performance of avalanche photodiode electron detectors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kawauchi, Taizo; Wilde, Markus; Fukutani, Katsuyuki
2009-01-01
Avalanche photodiodes (APDs) are efficient detectors for electrons with energies below 100 keV. The damaging effects of 8 keV electron beam irradiation on the dark current and the output signal of the APD detector were investigated in this study. The APD dark current increases after electron doses exceeding 1.4x10{sup 13} cm{sup -2}. Preirradiation by high doses of 8 keV electrons further causes a deformation of the pulse height distribution of the APD output in the subsequent detection of low-flux electrons. This effect is particularly prominent when the energy of the detected electrons is lower than that of the damaging electrons.more » By comparing the experimental data with results of a simulation based on an electron trapping model, we conclude that the degradation of the APD performance is attributable to an enhancement of secondary-electron trapping at irradiation induced defects.« less
Gonnissen, J; De Backer, A; den Dekker, A J; Sijbers, J; Van Aert, S
2016-11-01
In the present paper, the optimal detector design is investigated for both detecting and locating light atoms from high resolution scanning transmission electron microscopy (HR STEM) images. The principles of detection theory are used to quantify the probability of error for the detection of light atoms from HR STEM images. To determine the optimal experiment design for locating light atoms, use is made of the so-called Cramér-Rao Lower Bound (CRLB). It is investigated if a single optimal design can be found for both the detection and location problem of light atoms. Furthermore, the incoming electron dose is optimised for both research goals and it is shown that picometre range precision is feasible for the estimation of the atom positions when using an appropriate incoming electron dose under the optimal detector settings to detect light atoms. Copyright © 2016 Elsevier B.V. All rights reserved.
A method to detect ultra high energy electrons using earth's magnetic field as a radiator
NASA Technical Reports Server (NTRS)
Stephens, S. A.; Balasubrahmanyan, V. K.
1983-01-01
It is pointed out that the detection of electrons with energies exceeding a few TeV, which lose energy rapidly through synchrotron and inverse Compton processes, would provide valuable information on the distribution of sources and on the propagation of cosmic rays in the solar neighborhood. However, it would not be possible to measure the energy spectrum beyond a few TeV with any of the existing experimental techniques. The present investigation is, therefore concerned with the possibility of detecting electrons with energies exceeding a few TeV on the basis of the photons emitted through synchrotron radiation in the earth's magnetic field. Attention is given to the synchrotron radiation of electrons in the earth's magnetic field, detector response and energy estimation, and the characteristics of an ideal detector, capable of detecting photons with energies equal to or greater than 20 keV.
Data fusion approach to threat assessment for radar resources management
NASA Astrophysics Data System (ADS)
Komorniczak, Wojciech; Pietrasinski, Jerzy; Solaiman, Basel
2002-03-01
The paper deals with the problem of the multifunction radar resources management. The problem consists of target/tasks ranking and tasks scheduling. The paper is focused on the target ranking, with the data fusion approach. The data from the radar (object's velocity, range, altitude, direction etc.), IFF system (Identification Friend or Foe) and ESM system (Electronic Support Measures - information concerning threat's electro - magnetic activities) is used to decide of the importance assignment for each detected target. The main problem consists of the multiplicity of various types of the input information. The information from the radar is of the probabilistic or ambiguous imperfection type and the IFF information is of evidential type. To take the advantage of these information sources the advanced data fusion system is necessary. The system should deal with the following situations: fusion of the evidential and fuzzy information, fusion of the evidential information and a'priori information. The paper describes the system which fuses the fuzzy and the evidential information without previous change to the same type of information. It is also described the proposal of using of the dynamic fuzzy qualifiers. The paper shows the results of the preliminary system's tests.
The Primary Care Electronic Library (PCEL) five years on: open source evaluation of usage.
Robinson, Judas; de Lusignan, Simon; Kostkova, Patty
2005-01-01
The Primary Care Electronic Library (PCEL) is a collection of indexed and abstracted internet resources. PCEL contains a directory of quality-assured internet material with associated search facilities. PCEL has been indexed, using metadata and established taxonomies. Site development requires an understanding of usage; this paper reports the use of open source tools to evaluate usage. This evaluation was conducted during a six-month period of development of PCEL. To use open source to evaluate changes in usage of an electronic library. We defined data we needed for analysis; this included: page requests, visits, unique visitors, page requests per visit, geographical location of users, NHS users, chronological information about users and resources used. During the evaluation period, page requests increased from 3500 to 10,000; visits from 1250 to 2300; and unique visitors from 750 to 1500. Up to 83% of users come from the UK, 15% were NHS users. The page requests of NHS users are slowly increasing but not as fast as requests by other users in the UK. PCEL is primarily used Monday to Friday, 9 a.m. to 5 p.m. Monday is the busiest day with use lessening through the week. NHS users had a different list of top ten resources accessed than non-NHS users, with only four resources appearing in both. Open source tools provide useful data which can be used to evaluate online resources. Improving the functionality of PCEL has been associated with increased use.
Bayesian adaptive survey protocols for resource management
Halstead, Brian J.; Wylie, Glenn D.; Coates, Peter S.; Casazza, Michael L.
2011-01-01
Transparency in resource management decisions requires a proper accounting of uncertainty at multiple stages of the decision-making process. As information becomes available, periodic review and updating of resource management protocols reduces uncertainty and improves management decisions. One of the most basic steps to mitigating anthropogenic effects on populations is determining if a population of a species occurs in an area that will be affected by human activity. Species are rarely detected with certainty, however, and falsely declaring a species absent can cause improper conservation decisions or even extirpation of populations. We propose a method to design survey protocols for imperfectly detected species that accounts for multiple sources of uncertainty in the detection process, is capable of quantitatively incorporating expert opinion into the decision-making process, allows periodic updates to the protocol, and permits resource managers to weigh the severity of consequences if the species is falsely declared absent. We developed our method using the giant gartersnake (Thamnophis gigas), a threatened species precinctive to the Central Valley of California, as a case study. Survey date was negatively related to the probability of detecting the giant gartersnake, and water temperature was positively related to the probability of detecting the giant gartersnake at a sampled location. Reporting sampling effort, timing and duration of surveys, and water temperatures would allow resource managers to evaluate the probability that the giant gartersnake occurs at sampled sites where it is not detected. This information would also allow periodic updates and quantitative evaluation of changes to the giant gartersnake survey protocol. Because it naturally allows multiple sources of information and is predicated upon the idea of updating information, Bayesian analysis is well-suited to solving the problem of developing efficient sampling protocols for species of conservation concern.
Single-Electron Detection and Spectroscopy via Relativistic Cyclotron Radiation.
Asner, D M; Bradley, R F; de Viveiros, L; Doe, P J; Fernandes, J L; Fertl, M; Finn, E C; Formaggio, J A; Furse, D; Jones, A M; Kofron, J N; LaRoque, B H; Leber, M; McBride, E L; Miller, M L; Mohanmurthy, P; Monreal, B; Oblath, N S; Robertson, R G H; Rosenberg, L J; Rybka, G; Rysewyk, D; Sternberg, M G; Tedeschi, J R; Thümmler, T; VanDevender, B A; Woods, N L
2015-04-24
It has been understood since 1897 that accelerating charges must emit electromagnetic radiation. Although first derived in 1904, cyclotron radiation from a single electron orbiting in a magnetic field has never been observed directly. We demonstrate single-electron detection in a novel radio-frequency spectrometer. The relativistic shift in the cyclotron frequency permits a precise electron energy measurement. Precise beta electron spectroscopy from gaseous radiation sources is a key technique in modern efforts to measure the neutrino mass via the tritium decay end point, and this work demonstrates a fundamentally new approach to precision beta spectroscopy for future neutrino mass experiments.
ERIC Educational Resources Information Center
Nosofsky, Robert M.; Donkin, Chris
2016-01-01
We report an experiment designed to provide a qualitative contrast between knowledge-limited versions of mixed-state and variable-resources (VR) models of visual change detection. The key data pattern is that observers often respond "same" on big-change trials, while simultaneously being able to discriminate between same and small-change…
Light detection and ranging (LIDAR): an emerging tool for multiple resource inventory.
Stephen E. Reutebuch; Hans-Erik Andersen; Robert J. McGaughey
2005-01-01
Airborne laser scanning of forests has been shown to provide accurate terrain models and, at the same time, estimates of multiple resource inventory variables through active sensing of three-dimensional (3D) forest vegetation. Brief overviews of airborne laser scanning technology [often referred to as "light detection and ranging" (LIDAR)] and research...
Improved model for detection of homogeneous production batches of electronic components
NASA Astrophysics Data System (ADS)
Kazakovtsev, L. A.; Orlov, V. I.; Stashkov, D. V.; Antamoshkin, A. N.; Masich, I. S.
2017-10-01
Supplying the electronic units of the complex technical systems with electronic devices of the proper quality is one of the most important problems for increasing the whole system reliability. Moreover, for reaching the highest reliability of an electronic unit, the electronic devices of the same type must have equal characteristics which assure their coherent operation. The highest homogeneity of the characteristics is reached if the electronic devices are manufactured as a single production batch. Moreover, each production batch must contain homogeneous raw materials. In this paper, we propose an improved model for detecting the homogeneous production batches of shipped lot of electronic components based on implementing the kurtosis criterion for the results of non-destructive testing performed for each lot of electronic devices used in the space industry.
Improvements of low-level radioxenon detection sensitivity by a state-of-the art coincidence setup.
Cagniant, A; Le Petit, G; Gross, P; Douysset, G; Richard-Bressand, H; Fontaine, J-P
2014-05-01
The ability to quantify isotopic ratios of 135, 133 m, 133 and 131 m radioxenon is essential for the verification of the Comprehensive Nuclear-Test Ban Treaty (CTBT). In order to improve detection limits, CEA has developed a new on-site setup using photon/electron coincidence (Le Petit et al., 2013. J. Radioanal. Nucl. Chem., DOI : 10.1007/s 10697-013-2525-8.). Alternatively, the electron detection cell equipped with large silicon chips (PIPS) can be used with HPGe detector for laboratory analysis purpose. This setup allows the measurement of β/γ coincidences for the detection of (133)Xe and (135)Xe; and K-shell Conversion Electrons (K-CE)/X-ray coincidences for the detection of (131m)Xe, (133m)Xe and (133)Xe as well. Good energy resolution of 11 keV at 130 keV and low energy threshold of 29 keV for the electron detection were obtained. This provides direct discrimination between K-CE from (133)Xe, (133m)Xe and (131m)Xe. Estimation of Minimum Detectable Activity (MDA) for (131m)Xe is in the order of 1mBq over a 4 day measurement. An analysis of an environmental radioxenon sample using this method is shown. © 2013 The Authors. Published by Elsevier Ltd All rights reserved.
ERIC Educational Resources Information Center
Cronin, Mary J.
1993-01-01
Review of major information providers on the Internet that offer business resources focuses on U.S. government, United Nations, and European Community information and suggests sources for keeping current with new information offerings. Electronic bulletin boards, LC MARVEL, university Gophers, and TECnet are described; and access and subscription…
ERIC Educational Resources Information Center
Jackson, Mary E.
2002-01-01
Explains portals as tools that gather a variety of electronic information resources, including local library resources, into a single Web page. Highlights include cross-database searching; integration with university portals and course management software; the ARL (Association of Research Libraries) Scholars Portal Initiative; and selected vendors…
Low-Cost Virtual Laboratory Workbench for Electronic Engineering
ERIC Educational Resources Information Center
Achumba, Ifeyinwa E.; Azzi, Djamel; Stocker, James
2010-01-01
The laboratory component of undergraduate engineering education poses challenges in resource constrained engineering faculties. The cost, time, space and physical presence requirements of the traditional (real) laboratory approach are the contributory factors. These resource constraints may mitigate the acquisition of meaningful laboratory…
Schnell, E H
1995-01-01
In 1994, the John A. Prior Health Sciences Library at Ohio State University began to develop a World Wide Web demonstration project, the Biomedically Oriented Navigator of Electronic Services (BONES). The initial intent of BONES was to facilitate the health professional's access to Internet resources by organizing them in a systematic manner. The project not only met this goal but also helped identify the resources needed to launch a full-scale Web library service. This paper discusses the tasks performed and resources used in the development of BONES and describes the creation and organization of documents on the BONES Web server. The paper also discusses the outcomes of the project and the impact on the library's staff and services. PMID:8547903
NASA Technical Reports Server (NTRS)
Thakoor, Anil
1990-01-01
Viewgraphs on electronic neural networks for space station are presented. Topics covered include: electronic neural networks; electronic implementations; VLSI/thin film hybrid hardware for neurocomputing; computations with analog parallel processing; features of neuroprocessors; applications of neuroprocessors; neural network hardware for terrain trafficability determination; a dedicated processor for path planning; neural network system interface; neural network for robotic control; error backpropagation algorithm for learning; resource allocation matrix; global optimization neuroprocessor; and electrically programmable read only thin-film synaptic array.
Modular droplet actuator drive
NASA Technical Reports Server (NTRS)
Pollack, Michael G. (Inventor); Paik, Philip (Inventor)
2011-01-01
A droplet actuator drive including a detection apparatus for sensing a property of a droplet on a droplet actuator; circuitry for controlling the detection apparatus electronically coupled to the detection apparatus; a droplet actuator cartridge connector arranged so that when a droplet actuator cartridge electronically is coupled thereto: the droplet actuator cartridge is aligned with the detection apparatus; and the detection apparatus can sense the property of the droplet on a droplet actuator; circuitry for controlling a droplet actuator coupled to the droplet actuator connector; and the droplet actuator circuitry may be coupled to a processor.
The Electronic Library Workstation--Today.
ERIC Educational Resources Information Center
Nolte, James
1990-01-01
Describes the components--hardware, software and applications, CD-ROM and online reference resources, and telecommunications links--of an electronic library workstation in use at Clarkson University (Potsdam, New York). Data manipulation, a hypothetical research scenario, and recommended workstation capabilities are also discussed. (MES)
Heterogeneous Concurrent Modeling and Design in Java (Volume 3: Ptolemy II Domains)
2008-04-15
Starting the model 88 6.5.3. Atomic Communication in Concurrent Execution 90 6.5.4. Detecting Deadlocks: 90 6.6. Application to Resource Management 90 6.6.1...Resource Management Demo 90 6.6.2. ResourcePool 91 6.7. Threads in an Actor 91 6.7.1. Creating Extra Threads in an Actor 91 6.7.2. Manually Blocking...Local Time Management 117 8.4.2. Detecting Deadlock 118 8.4.3. Ending Execution 118 8.5. Example DDE Applications 119 9. PN Domain 121 9.1
Efficient automatic OCR word validation using word partial format derivation and language model
NASA Astrophysics Data System (ADS)
Chen, Siyuan; Misra, Dharitri; Thoma, George R.
2010-01-01
In this paper we present an OCR validation module, implemented for the System for Preservation of Electronic Resources (SPER) developed at the U.S. National Library of Medicine.1 The module detects and corrects suspicious words in the OCR output of scanned textual documents through a procedure of deriving partial formats for each suspicious word, retrieving candidate words by partial-match search from lexicons, and comparing the joint probabilities of N-gram and OCR edit transformation corresponding to the candidates. The partial format derivation, based on OCR error analysis, efficiently and accurately generates candidate words from lexicons represented by ternary search trees. In our test case comprising a historic medico-legal document collection, this OCR validation module yielded the correct words with 87% accuracy and reduced the overall OCR word errors by around 60%.
1973-09-01
This Earth Resource Experiment Package (EREP) photograph of the Uncompahgre area of Colorado was electronically acquired in September of 1973 by the Multi-spectral Scarner, Skylab Experiment S192. EREP images were used to analyze the vegetation conditions and landscape characteristic of this area. Skylab's Earth sensors played the dual roles of gathering information about the planet and perfecting instruments and techniques for future satellites and manned stations. An array of six fixed cameras, another for high resolution, and the astronauts' handheld cameras photographed surface features. Other instruments, recording on magnetic tape, measured the reflectivity of plants, soils, and water. Radar measured the altitude of land and water surfaces. The sensors' objectives were to survey croplands and forests, identify soils and rock types, map natural features and urban developments, detect sediments and the spread of pollutants, study clouds and the sea, and determine the extent of snow and ice cover.
Strle, Drago; Štefane, Bogdan; Zupanič, Erik; Trifkovič, Mario; Maček, Marijan; Jakša, Gregor; Kvasič, Ivan; Muševič, Igor
2014-01-01
The article offers a comparison of the sensitivities for vapour trace detection of Trinitrotoluene (TNT) explosives of two different sensor systems: a chemo-mechanical sensor based on chemically modified Atomic Force Microscope (AFM) cantilevers based on Micro Electro Mechanical System (MEMS) technology with optical detection (CMO), and a miniature system based on capacitive detection of chemically functionalized planar capacitors with interdigitated electrodes with a comb-like structure with electronic detection (CE). In both cases (either CMO or CE), the sensor surfaces are chemically functionalized with a layer of APhS (trimethoxyphenylsilane) molecules, which give the strongest sensor response for TNT. The construction and calibration of a vapour generator is also presented. The measurements of the sensor response to TNT are performed under equal conditions for both systems, and the results show that CE system with ultrasensitive electronics is far superior to optical detection using MEMS. Using CMO system, we can detect 300 molecules of TNT in 10+12 molecules of N2 carrier gas, whereas the CE system can detect three molecules of TNT in 10+12 molecules of carrier N2. PMID:24977388
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
This report summarizes activities of the Amarillo National Resource Center for Plutonium during the quarter. The report describes the Electronic Resource Library; DOE support activities; current and future environmental health and safety programs; pollution prevention and pollution avoidance; communication, education, training, and community involvement programs; and nuclear and other material studies, including plutonium storage and disposition studies.
ERIC Educational Resources Information Center
Fry, Amy; Rich, Linda
2011-01-01
In early 2010, library staff at Bowling Green State University (BGSU) in Ohio designed and conducted a usability study of key parts of the library web site, focusing on the web pages generated by the library's electronic resources management system (ERM) that list and describe the library's databases. The goal was to discover how users find and…
High-energy electron experiments (HEP) aboard the ERG (Arase) satellite
NASA Astrophysics Data System (ADS)
Mitani, Takefumi; Takashima, Takeshi; Kasahara, Satoshi; Miyake, Wataru; Hirahara, Masafumi
2018-05-01
This paper reports the design, calibration, and operation of high-energy electron experiments (HEP) aboard the exploration of energization and radiation in geospace (ERG) satellite. HEP detects 70 keV-2 MeV electrons and generates a three-dimensional velocity distribution for these electrons in every period of the satellite's rotation. Electrons are detected by two instruments, namely HEP-L and HEP-H, which differ in their geometric factor (G-factor) and range of energies they detect. HEP-L detects 70 keV-1 MeV electrons and its G-factor is 9.3 × 10-4 cm2 sr at maximum, while HEP-H observes 0.7-2 MeV electrons and its G-factor is 9.3 × 10-3 cm2 sr at maximum. The instruments utilize silicon strip detectors and application-specific integrated circuits to readout the incident charge signal from each strip. Before the launch, we calibrated the detectors by measuring the energy spectra of all strips using γ-ray sources. To evaluate the overall performance of the HEP instruments, we measured the energy spectra and angular responses with electron beams. After HEP was first put into operation, on February 2, 2017, it was demonstrated that the instruments performed normally. HEP began its exploratory observations with regard to energization and radiation in geospace in late March 2017. The initial results of the in-orbit observations are introduced briefly in this paper.[Figure not available: see fulltext.
Progress towards a measurement of the UHE cosmic ray electron flux using the CREST Instrument
NASA Astrophysics Data System (ADS)
Musser, Jim; Wakely, Scott; Coutu, Stephane; Geske, Matthew; Nutter, Scott; Tarle, Gregory; Park, Nahee; Schubnell, Michael; Gennaro, Joseph; Muller, Dietrich
2012-07-01
Electrons of energy beyond about 3 TeV have never been detected in the flux of cosmic rays at Earth despite strong evidence of their presence in a number of supernova remnants (e.g., SN 1006). The detection of high energy electrons at Earth would be extremely significant, yielding information about the spatial distribution of nearby cosmic ray sources. With the Cosmic Ray Electron Synchrotron Telescope (CREST), our collaboration has adopted a novel approach to the detection of electrons of energies between 2 and 50 TeV which results in a substantial increase in the acceptance and sensitivity of the apparatus relative to its physics size. The first LDB flight of the CREST detector took place in January 2012, with a float duration of approximately 10 days. In this paper we describe the flight performance of the instrument, and progress in the analysis of the data obtained in this flight.
Zhang, Huang-Qin; Zhu, Zhen-Hua; Qian, Da-Wei; Weng, Ze-Bin; Guo, Sheng; Duan, Jin-Ao; Lei, Zhen-Hong; Li, An-Ping
2016-12-01
This study intends to explore the potential resource-orientedutilization value of the flower of Sophora flavescents by analyzing alkaloids and flavonoids in the flower of S. flavescens from Shanxi province. This study established a rapid UPLC-TQ-MS/MS method that is used for determination of seven alkaloids and seven flavonoids in the flower of S.flavescens. The different florescences all have the seven detected alkaloids such as cytisine, oxy-matrine, oxy-sophocarpine, sophoridine, N-methylcytisine, matrine, sophocarpine.The total contents of detected alkaloids are as follows: flower buds 1.47%, primal flowers 1.34%, full bloomed flowers 1.17%, faded flowers 1.01%. The top three contents of alkaloids are N-methylcytisine , oxy-sophocarpine and oxymatrine, accounting for about 83% of the total amount of detected alkaloids. All the samples in different florescences have the seven detected flavonoids such as rutin, luteolin, quercetin, isoquercitrin, trifolirhizin, kurarinone, and kushenol I. The total contents of detected alkaloids are as follows: flower buds 495.2 μg•g⁻¹, primal flowers 313.7 μg•g⁻¹, faded flowers 224.2 μg•g⁻¹, full bloomed flowers 193.0 μg•g⁻¹. The content of luteolinis relatively higher than other detected flavonoids, accounting for about 89%-94% of the total amount of detected flavonoids. The results indicated that the flower of S.flavescens could be an important material resource to obtain the resourceful alkaloids. This result can provide scientific basis for resource-oriented utilization and industrial development of the flower of S. flavescens. Copyright© by the Chinese Pharmaceutical Association.
Wind and Solar Resource Assessment of Sri Lanka and the Maldives (CD-ROM)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Elliott, D.; Schwartz, M.; Scott, G.
2003-08-01
The Wind and Solar Resource Assessment of Sri Lanka and the Maldives CD contains an electronic version of Wind Energy Resource Atlas of Sri Lanka and the Maldives (NREL/TP-500-34518), Solar Resource Assessment for Sri Lanka and the Maldives (NREL/TO-710-34645), Sri Lanka Wind Farm Analysis and Site Selection Assistance (NREL/SR-500-34646), GIS Data Viewer (software and data files with a readme file), and Hourly Solar and Typical Meteorological Year Data with a readme file.
Detecting Kondo Entanglement by Electron Conductance
NASA Astrophysics Data System (ADS)
Yoo, Gwangsu; Lee, S.-S. B.; Sim, H.-S.
2018-04-01
Quantum entanglement between an impurity spin and electrons nearby is a key property of the single-channel Kondo effects. We show that the entanglement can be detected by measuring electron conductance through a double quantum dot in an orbital Kondo regime. We derive a relation between the entanglement and the conductance, when the SU(2) spin symmetry of the regime is weakly broken. The relation reflects the universal form of many-body states near the Kondo fixed point. Using it, the spatial distribution of the entanglement—hence, the Kondo cloud—can be detected, with breaking of the symmetry spatially nonuniformly by electrical means.
Subdecoherence time generation and detection of orbital entanglement in quantum dots.
Brange, F; Malkoc, O; Samuelsson, P
2015-05-01
Recent experiments have demonstrated subdecoherence time control of individual single-electron orbital qubits. Here we propose a quantum-dot-based scheme for generation and detection of pairs of orbitally entangled electrons on a time scale much shorter than the decoherence time. The electrons are entangled, via two-particle interference, and transferred to the detectors during a single cotunneling event, making the scheme insensitive to charge noise. For sufficiently long detector dot lifetimes, cross-correlation detection of the dot charges can be performed with real-time counting techniques, providing for an unambiguous short-time Bell inequality test of orbital entanglement.
Wilson, Alphus D.
2015-01-01
Recent advancements in the use of electronic-nose (e-nose) devices to analyze human breath profiles for the presence of specific volatile metabolites, known as biomarkers or chemical bio-indicators of specific human diseases, metabolic disorders and the overall health status of individuals, are providing the potential for new noninvasive tools and techniques useful to point-of-care clinical disease diagnoses. This exciting new area of electronic disease detection and diagnosis promises to yield much faster and earlier detection of human diseases and disorders, allowing earlier, more effective treatments, resulting in more rapid patient recovery from various afflictions. E-nose devices are particularly suited for the field of disease diagnostics, because they are sensitive to a wide range of volatile organic compounds (VOCs) and can effectively distinguish between different complex gaseous mixtures via analysis of electronic aroma sensor-array output profiles of volatile metabolites present in the human breath. This review provides a summary of some recent developments of electronic-nose technologies, particularly involving breath analysis, with the potential for providing many new diagnostic applications for the detection of specific human diseases associated with different organs in the body, detectable from e-nose analyses of aberrant disease-associated VOCs present in air expired from the lungs. PMID:25738426
NASA Astrophysics Data System (ADS)
Radulescu, A.; Arend, N.; Drochner, M.; Ioffe, A.; Kemmerling, G.; Ossovyi, V.; Staringer, S.; Vehres, G.; McKinny, K.; Olechnowicz, B.; Yen, D.
2016-09-01
A new detection system based on an array of 3He tubes and innovative fast detection electronics was designed and produced by GE Reuter Stokes for the high-intensity small-angle neutron scattering diffractometer KWS-2, operated by the Jülich Centre for Neutron Science (JCNS) at the Heinz Meier-Leibnitz Zentrum (MLZ). The new detector consists of a panel array of 144 3He tubes and a new fast read-out electronics. The electronics is mounted in a closed case in the backside of the 3He tubes panel array and will operate at ambient atmosphere under cooling air stream. The new detection system is composed of eighteen 8-pack modules of 3He-tubes that work independently of one another (each unit has its own processor and electronics). Knowing beforehand the performance of one detector unit and of one single tube detector is prerequisite for tuning and maximizing the performance of the complete detection system. In this paper we present the results of the tests of the prototyped 8-pack of 3He-tubes and corresponding electronics, which have been carried out at the JCNS instruments KWS-2 (in high flux conditions) and TREFF.
ERIC Educational Resources Information Center
Kapoor, Kanta
2010-01-01
Purpose: The purpose of this paper is to quantify the use of electronic journals in comparison with the print collections in the Guru Gobind Singh Indraprastha University Library. Design/methodology/approach: A detailed analysis was made of the use of lending services, the Xerox facility and usage of electronic journals such as Science Direct,…
eIFL (Electronic Information for Libraries): A Global Initiative of the Soros Foundations Network.
ERIC Educational Resources Information Center
Feret, Blazej; Kay, Michael
This paper presents the history, current status, and future development of eIFL (Electronic Information for Libraries Direct)--a large-scale project run by the Soros Foundations Network and the Open Society Institute. The project aims to provide libraries in developing countries with access to a menu of electronic information resources. In 1999,…
Design of an integrated sensor system for the detection of traces of different molecules in the air
NASA Astrophysics Data System (ADS)
Strle, D.; Muševič, I.
2015-04-01
This article presents the design of a miniature detection system and its associated signal processing electronics, which can detect and selectively recognize vapor traces of different materials in the air - including explosives. It is based on the array of surface-functionalized COMB capacitive sensors and extremely low noise, analog, integrated electronic circuit, hardwired digital signal processing hardware and additional software running on a PC. The instrument is sensitive and selective, consumes a minimum amount of energy, is very small (few mm3) and cheap to produce in large quantities, and is insensitive to mechanical influences. Using an electronic detection system built of low noise analog front-end and hard-wired digital signal processing, it is possible to detect less than 0.3ppt of TNT molecules in the atmosphere (3 TNT molecules in 1013 molecules of the air) at 25°C on a 1 Hz bandwidth using very small volume and approx. 10 mA current from a 5V supply voltage. The sensors are implemented in a modified MEMS process and analog electronics in 0.18 um CMOS technology.
Mesoporous aluminium organophosphonates: a reusable chemsensor for the detection of explosives
NASA Astrophysics Data System (ADS)
Li, Dongdong; Yu, Xiang
2016-07-01
Rapid and sensitive detection of explosives is in high demand for homeland security and public safety. In this work, electron-rich of anthracene functionalized mesoporous aluminium organophosphonates (En-AlPs) were synthesized by a one-pot condensation process. The mesoporous structure and strong blue emission of En-AlPs were confirmed by the N2 adsorption-desorption isotherms, transmission electron microscopy images and fluorescence spectra. The materials En-AlPs can serve as sensitive chemosensors for various electron deficient nitroderivatives, with the quenching constant and the detection limit up to 1.5×106 M-1 and 0.3 ppm in water solution. More importantly, the materials can be recycled for many times by simply washed with ethanol, showing potential applications in explosives detection.
Emission and detection of surface acoustic waves by AlGaN/GaN high electron mobility transistors
NASA Astrophysics Data System (ADS)
Shao, Lei; Zhang, Meng; Banerjee, Animesh; Bhattacharya, Pallab; Pipe, Kevin P.
2011-12-01
Using integrated interdigital transducers (IDTs), we demonstrate the emission of surface acoustic waves (SAWs) by AlGaN/GaN high electron mobility transistors (HEMTs) under certain bias conditions through dynamic screening of the HEMTs vertical field by modulation of its two-dimensional electron gas. We show that a strong SAW signal can be detected if the IDT geometry replicates the HEMT electrode geometry at which RF bias is applied. In addition to characterizing SAW emission during both gate-source and drain-source modulation, we demonstrate SAW detection by HEMTs. Integrated HEMT-IDT structures could enable real-time evaluation of epitaxial degradation as well as high-speed, amplified detection of SAWs.
Vörös, K; Bonnevie, A; Reiczigel, J
2012-04-24
Cardiac auscultation is one of the most important parts of the cardiological examination traditionally performed with acoustic stethoscopes. The aim of this study was to compare the sensitivities and the diagnostic capabilities of traditional and electronic stethoscopes in detecting canine heart murmurs. The study was performed on 21 dogs referred for cardiologic examination with suspected heart murmurs. Six out of these dogs had cardiac murmurs bilaterally. Cardiac auscultation was performed independently by a final-year veterinary student (AB=I1) and by an experienced clinician (KV=I2), both using a traditional and a Welch Allyn Meditron electronic sensor-based stethoscope. Final diagnoses were established by echocardiography and by digital phonocardiography. Correct detection of a murmur was made by I1 with a traditional stethoscope in 20/27 (74.0%) of the suspected murmurs (p=0.30, kappa[κ] =0.2) and with the electronic stethoscope in 26/27 (96.3%), respectively (p=0.0013, κ=0.75). I2 correctly detected the murmurs with the traditional stethoscope in 25/27 (92.6%) cases (p=0.0013, κ=0.75) and with the electronic stethoscope in all 27/27 (100%) cases (p=0.00012, κ=1). Agreements of murmur intensity gradings between traditional and electronic stethoscopes were highly significant (I1: p=6.9´10⁻⁸; κ=0.79), (I2: p=5.2´10⁻¹¹; κ=0.92). When grading the murmurs with the traditional stethoscope, there was a significant agreement between I1 and I2 (p=2.9´10⁻⁷; κ=0.79), being even higher with the electronic stethoscope (p=1.1´10⁻¹¹; κ=0.92). The electronic stethoscope was more sensitive than the traditional one in detecting and grading cardiac murmurs being especially useful for I1 with less experience. However, it can be suggested to use a traditional and an electronic stethoscopes simultaneously to optimally utilize their advantages.
Impact of e-alert systems on the care of patients with acute kidney injury.
Breighner, Crystal M; Kashani, Kianoush B
2017-09-01
With the recent advancement in electronic health record systems and meaningful use of information technology incentive programs (i.e., the American Recovery and Reinvestment Act, the Health Information Technology for Economic and Clinical Health Act, and the Centers for Medicare & Medicaid Services), interest in clinical decision support systems has risen. These systems have been used to examine a variety of different syndromes with variable reported effects. In recent years, electronic alerts (e-alerts) have been implemented at various institutions to decrease the morbidity associated with acute kidney injury (AKI). AKI is common, accounting for 1 in 7 hospital admissions, and is associated with increased length of hospital stay and mortality. AKI is often underrecognized, causing delayed intervention. The use of e-alerts may result in earlier recognition and intervention, as well as decreased morbidity and mortality. This must be balanced with the possibility of increased resource utilization that e-alerts may cause. Before widespread implementation, the ethical and legal consequences of not following e-alert recommendations must be established, and the optimal algorithm for AKI e-alert detection must be determined. Copyright © 2017 Elsevier Ltd. All rights reserved.
Journal Holdings - Betty Petersen Memorial Library
Resources NCEP Office Notes IT Resources Request an item* University of Maryland Research Affiliate Contact for Environmental Prediction (NCEP) NESDIS Center for Satellite Applications & Research (STAR (1949 - 1985) Series B (1948 - 1986) Arctic and Alpine Research Electronic version available through
Improving Electronic Resources through Holistic Budgeting
ERIC Educational Resources Information Center
Kusik, James P.; Vargas, Mark A.
2009-01-01
To establish a more direct link between its collections and the educational goals of Saint Xavier University, the Byrne Memorial Library has adopted a "holistic" approach to collection development. This article examines how traditional budget practices influenced the library's selection of resources and describes how holistic collection…
Evaluating a scalable model for implementing electronic health records in resource-limited settings.
Were, Martin C; Emenyonu, Nneka; Achieng, Marion; Shen, Changyu; Ssali, John; Masaba, John P M; Tierney, William M
2010-01-01
Current models for implementing electronic health records (EHRs) in resource-limited settings may not be scalable because they fail to address human-resource and cost constraints. This paper describes an implementation model which relies on shared responsibility between local sites and an external three-pronged support infrastructure consisting of: (1) a national technical expertise center, (2) an implementer's community, and (3) a developer's community. This model was used to implement an open-source EHR in three Ugandan HIV-clinics. Pre-post time-motion study at one site revealed that Primary Care Providers spent a third less time in direct and indirect care of patients (p<0.001) and 40% more time on personal activities (p=0.09) after EHRs implementation. Time spent by previously enrolled patients with non-clinician staff fell by half (p=0.004) and with pharmacy by 63% (p<0.001). Surveyed providers were highly satisfied with the EHRs and its support infrastructure. This model offers a viable approach for broadly implementing EHRs in resource-limited settings.
Increasing sensitivity of pulse EPR experiments using echo train detection schemes.
Mentink-Vigier, F; Collauto, A; Feintuch, A; Kaminker, I; Tarle, V; Goldfarb, D
2013-11-01
Modern pulse EPR experiments are routinely used to study the structural features of paramagnetic centers. They are usually performed at low temperatures, where relaxation times are long and polarization is high, to achieve a sufficient Signal/Noise Ratio (SNR). However, when working with samples whose amount and/or concentration are limited, sensitivity becomes an issue and therefore measurements may require a significant accumulation time, up to 12h or more. As the detection scheme of practically all pulse EPR sequences is based on the integration of a spin echo--either primary, stimulated or refocused--a considerable increase in SNR can be obtained by replacing the single echo detection scheme by a train of echoes. All these echoes, generated by Carr-Purcell type sequences, are integrated and summed together to improve the SNR. This scheme is commonly used in NMR and here we demonstrate its applicability to a number of frequently used pulse EPR experiments: Echo-Detected EPR, Davies and Mims ENDOR (Electron-Nuclear Double Resonance), DEER (Electron-Electron Double Resonance|) and EDNMR (Electron-Electron Double Resonance (ELDOR)-Detected NMR), which were combined with a Carr-Purcell-Meiboom-Gill (CPMG) type detection scheme at W-band. By collecting the transient signal and integrating a number of refocused echoes, this detection scheme yielded a 1.6-5 folds SNR improvement, depending on the paramagnetic center and the pulse sequence applied. This improvement is achieved while keeping the experimental time constant and it does not introduce signal distortion. Copyright © 2013 Elsevier Inc. All rights reserved.
Detection and categorization of bacteria habitats using shallow linguistic analysis
2015-01-01
Background Information regarding bacteria biotopes is important for several research areas including health sciences, microbiology, and food processing and preservation. One of the challenges for scientists in these domains is the huge amount of information buried in the text of electronic resources. Developing methods to automatically extract bacteria habitat relations from the text of these electronic resources is crucial for facilitating research in these areas. Methods We introduce a linguistically motivated rule-based approach for recognizing and normalizing names of bacteria habitats in biomedical text by using an ontology. Our approach is based on the shallow syntactic analysis of the text that include sentence segmentation, part-of-speech (POS) tagging, partial parsing, and lemmatization. In addition, we propose two methods for identifying bacteria habitat localization relations. The underlying assumption for the first method is that discourse changes with a new paragraph. Therefore, it operates on a paragraph-basis. The second method performs a more fine-grained analysis of the text and operates on a sentence-basis. We also develop a novel anaphora resolution method for bacteria coreferences and incorporate it with the sentence-based relation extraction approach. Results We participated in the Bacteria Biotope (BB) Task of the BioNLP Shared Task 2013. Our system (Boun) achieved the second best performance with 68% Slot Error Rate (SER) in Sub-task 1 (Entity Detection and Categorization), and ranked third with an F-score of 27% in Sub-task 2 (Localization Event Extraction). This paper reports the system that is implemented for the shared task, including the novel methods developed and the improvements obtained after the official evaluation. The extensions include the expansion of the OntoBiotope ontology using the training set for Sub-task 1, and the novel sentence-based relation extraction method incorporated with anaphora resolution for Sub-task 2. These extensions resulted in promising results for Sub-task 1 with a SER of 68%, and state-of-the-art performance for Sub-task 2 with an F-score of 53%. Conclusions Our results show that a linguistically-oriented approach based on the shallow syntactic analysis of the text is as effective as machine learning approaches for the detection and ontology-based normalization of habitat entities. Furthermore, the newly developed sentence-based relation extraction system with the anaphora resolution module significantly outperforms the paragraph-based one, as well as the other systems that participated in the BB Shared Task 2013. PMID:26201262
Akram, Arifa; Islam, S M Rashedul; Munshi, Saif Ullah; Tabassum, Shahina
2018-05-16
Transmission of Hepatitis B Virus (HBV) usually occurs due to the transfusion of blood or blood products from chronic HBV (CHB) or occult HBV infected (OBI) patients. Besides serological tests e.g. HBsAg and anti-HBc (total), detection of HBV-DNA is necessary for the diagnosis of OBI patients. Different nucleic acid tests (NATs) including real-time-Polymerase Chain Reaction (qPCR) are used for the detect HBV-DNA. The NATs are expensive and require technical expertise which are barriers to introducing them in resource-limited settings. This study was undertaken to evaluate the use of Loop-Mediated Isothermal Amplification (LAMP) assay as an alternative to qPCR for the detection of HBV-DNA in CHB and potential OBI patients in resource-limited settings. Following the published protocols with some modifications, a LAMP assay was developed for detection of HBV-DNA by either using a heat block followed by detection in an agarose gel or using a qPCR thermocycler. The LAMP assay was applied to supernatant prepared from heat treated serum collected from CHB and potential OBI patients. HBV viral load in serum was measured by qPCR using a single step HBV-DNA quantification kit. Among 200 samples tested, qPCR was capable to detect HBV-DNA in 25.5% of cases, whereas LAMP assay detected HBV-DNA in 43.5% cases. The qPCR was able to detect 11 (9.16%) potential OBI cases, whereas LAMP assay identified HBV-DNA in 43 (35.83%) cases. In addition to tests for HBsAg and/or anti-HBc (total), detection of HBV-DNA by LAMP assay may aid in preventing post-transfusion HBV infection in resource-limited settings. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Solari, Paolo; Sollai, Giorgia; Masala, Carla; Loy, Francesco; Palmas, Francesco; Sabatini, Andrea; Crnjar, Roberto
2017-04-01
Shrimp are an essential ecological component of marine ecosystems, and have commercial importance for human consumption and aquaculture. Like other decapod crustaceans, shrimp rely on chemical senses to detect and localize food resources by means of chemosensilla that are located mainly on the cephalothoracic appendages. Using the shrimp Palaemon adspersus, a model organism with omnivorous feeding behavior, we aimed to provide comparative information on the role of aesthetascs, antennular sensilla, and flicking behavior in food detection. To this end, we examined i) the morphology of antennular sensilla by field emission scanning electron microscopy, ii) the shrimp's sensitivity to a number of food-related compounds (amino acids and sugars) by means of whole-animal bioassays, and iii) the contribution of the aesthetasc sensilla to food detection. Our results showed that, aside from the aesthetascs, only three other main morphotypes of setae with chemoreceptive features were present in the antennules, thus accounting for relatively simple sensillar equipment. Nevertheless, we found broad-spectrum sensitivity of the shrimp to a number of amino acids (i.e., isoleucine, leucine, methionine, phenylalanine, glycine, tryptophan, cysteine, and tyrosine) and carbohydrates (trehalose, maltose, cellobiose, and fructose) that was consistent with the omnivorous or scavenging habits of the animal. Although aesthetasc ablation attenuated flicking behavior in a chemical stimulus-independent manner, success in detection and short-range localization of food did not rely on the presence of aesthetasc sensilla. This finding confirms the existence of a non-aesthetasc alternative pathway for feeding, with functional redundancy in simple generalist feeder models such as shrimp.
Testing, Testing...Managing Electronic Access in Disparate Times.
ERIC Educational Resources Information Center
Carrington, Bessie M.
1996-01-01
Duke University's Perkins Library (North Carolina) tests electronic resources and services for remote accessibility by examining capabilities on various platforms, operating systems, communications software, and World Wide Web browsers. Problems occur in establishing connections, screen display, navigation or retrieval, keyboard variations, and in…
Rethinking Electronic Portfolios to Promote Sustainability among Teachers
ERIC Educational Resources Information Center
Shepherd, Craig E.; Skrabut, Stan
2011-01-01
Electronic portfolios (eportfolios) can increase reflection, develop content and pedagogy skills and facilitate communication between teachers and administrators. However, they have limitations. Despite resources that teacher institutions devote to eportfolios, research suggests that most implementations are of limited duration. In a climate where…
30 CFR 62.174 - Follow-up corrective measures when a standard threshold shift is detected.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Follow-up corrective measures when a standard threshold shift is detected. 62.174 Section 62.174 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR UNIFORM MINE HEALTH REGULATIONS OCCUPATIONAL NOISE EXPOSURE § 62.174 Follow-up corrective measures when a standard...
30 CFR 62.174 - Follow-up corrective measures when a standard threshold shift is detected.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Follow-up corrective measures when a standard threshold shift is detected. 62.174 Section 62.174 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR UNIFORM MINE HEALTH REGULATIONS OCCUPATIONAL NOISE EXPOSURE § 62.174 Follow-up corrective measures when a standard...
30 CFR 62.174 - Follow-up corrective measures when a standard threshold shift is detected.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Follow-up corrective measures when a standard threshold shift is detected. 62.174 Section 62.174 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR UNIFORM MINE HEALTH REGULATIONS OCCUPATIONAL NOISE EXPOSURE § 62.174 Follow-up corrective measures when a standard...
30 CFR 62.174 - Follow-up corrective measures when a standard threshold shift is detected.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Follow-up corrective measures when a standard threshold shift is detected. 62.174 Section 62.174 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR UNIFORM MINE HEALTH REGULATIONS OCCUPATIONAL NOISE EXPOSURE § 62.174 Follow-up corrective measures when a standard...
Electromechanical Displacement Detection With an On-Chip High Electron Mobility Transistor Amplifier
NASA Astrophysics Data System (ADS)
Oda, Yasuhiko; Onomitsu, Koji; Kometani, Reo; Warisawa, Shin-ichi; Ishihara, Sunao; Yamaguchi, Hiroshi
2011-06-01
We developed a highly sensitive displacement detection scheme for a GaAs-based electromechanical resonator using an integrated high electron mobility transistor (HEMT). Piezoelectric voltage generated by the vibration of the resonator is applied to the gate of the HEMT, resulting in the on-chip amplification of the signal voltage. This detection scheme achieves a displacement sensitivity of ˜9 pm·Hz-1/2, which is one of the highest among on-chip purely electrical displacement detection schemes at room temperature.
48 CFR 252.244-7001 - Contractor purchasing system administration.
Code of Federal Regulations, 2014 CFR
2014-10-01
....246-7007, Contractor Counterfeit Electronic Part Detection and Avoidance System, if applicable; (20... Defense to rely upon information produced by the system that is needed for management purposes. (b... Counterfeit Electronic Part Detection and Avoidance System; (2) Provide for an organizational and...
Use of the JPL Electronic Nose to detect leaks and spills in an enclosed environment
NASA Technical Reports Server (NTRS)
Ryan, Margaret A.; Homer, M. L.; Zhou, H.; Pelletier, C. C.; Manatt, K.; Jewell, A. D.; Kisor, A.; Shevade, A. V.; Lewis, C. R.; Taylor, C. J.;
2006-01-01
An electronic nose to be used as an air quality monitor in human habitats in space has been developed at the Jet Propulsion Laboratory. This device is capable of detecting, identifying and quantifying several organic and inorganic chemical species which might be present as contaminants in spacecraft air. The complete portable device, including sensors, electronics, and software for data analysis, has been extensively tested.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lescop, B.; Badeau, G.; Ivanovic, S.
Today, ISIS research reactor is an essential tool for Education and Training programs organized by the National Institute for Nuclear Science and Technology (INSTN) from CEA. In the field of nuclear instrumentation, the INSTN offers both, theoretical courses and training courses on the use of neutron detection systems taking advantage of the ISIS research reactor for the supply of a wide range of neutron fluxes. This paper describes the content of the training carried out on the use of neutron detectors and detection systems, on-site or remote. The ISIS reactor is a 700 kW open core pool type reactor. Themore » facility is very flexible since neutron detectors can be inserted into the core or its vicinity, and be used at different levels of power according to the needs of the course. Neutron fluxes, typically ranging from 1 to 10{sup 12} n/cm{sup 2}.s, can be obtained for the characterisation of the neutron detectors and detection systems. For the monitoring of the neutron density at low level of power, the Instrumentation and Control (I and C) system of the reactor is equipped with two detection systems, named BN1 and BN2. Each way contains a fission chamber, type CFUL01, connected to an electronic system type SIREX.The system works in pulse mode and exhibits two outputs: the counting rate and the doubling time. For the high level of power, the I and C is equipped with two detection systems HN1 and HN2.Each way contain a boron ionization chamber (type CC52) connected to an electronics system type SIREX. The system works in current mode and has two outputs: the current and the doubling time. For each mode, the trainees can observe and measure the signal at the different stages of the electronic system, with an oscilloscope. They can understand the role of each component of the detection system: detector, cable and each electronic block. The limitation of the detection modes and their operating range can be established from the measured signal. The trainees can also modify the settings of the electronic system, such as the high voltage and the discrimination level in order to obtain all the characteristic curves of the detectors. These curves are used to define the right setting of the electronic system and to discuss the expected degradation of the detector signal resulting from the detector damage under the integrated neutron and gamma fluxes. Moreover, in addition to the study of the neutron detection systems itself, the integration of the measurements made by these detection systems in the logic of the safety system of the nuclear reactor is also addressed. Providing the trainees with an extensive overview of each part of the neutron monitoring instrumentation apply to a nuclear reactor, hands-on measurements on the ISIS reactor play a major role in ensuring a practical and comprehensive understanding of the neutron detection system and their integration in the safety system of nuclear reactors. It also gives a solid background for the follow up and the development of the neutron detection systems. In addition to on-reactor training, Internet Reactor Laboratory capability has been implemented on the ISIS reactor in 2014. For the Internet Reactor Laboratory an extensive video conference system has been implemented on ISIS reactor. The system includes 4 cameras and the transmission of the video signal given by the supervision system of the reactor which records and processes the data of the reactor. According to the pedagogic needs during the training courses, the lecturer on the ISIS reactor chooses to broadcast the relevant information at each stage of the course. For example, graph showing the histogram of the counting and current as a function of the time, or the electrical signal observed on the oscilloscope, can be broadcasted trough internet. By interacting through the video conference, the remote classroom is able to ask for changes in the reactor power or settings of the detection systems. They can also ask for the broadcast of some particular information. At the guest institution, the information is displayed in two parts or screens, as shown in the Figure 3. Concerning the interaction with - and the feedback from - the remote classroom, the camera of the video system in the remote classroom is used to ensure the contact between the trainees and the lecturer and reactor operators. Thus, the Internet Reactor Laboratory is complementary to the on reactor training courses. It allows distant learning, reducing the overall cost of the course when this is necessary. It can efficiently be used for the development of the human resources needed by the nuclear industry and the nuclear programs in countries without research reactors.« less
Glassman, Nancy R.; Habousha, Racheline G.; Minuti, Aurelia; Schwartz, Rachel; Sorensen, Karen
2009-01-01
Due to the proliferation of electronic resources, fewer users visit the library. Traditional classroom instruction and in-person consultations are no longer sufficient in assisting library users. Librarians are constantly seeking new ways to interact with patrons and facilitate efficient use of electronic resources. This article describes the development, implementation, and evaluation of a project in which desktop-sharing software was used to reach out to users at remote locations. Various ways of using this tool are described, and challenges and implications for future expansion are discussed. PMID:20183031
43 CFR 11.20 - Notification and detection.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 11.20 Public Lands: Interior Office of the Secretary of the Interior NATURAL RESOURCE DAMAGE... CERCLA requires prompt notification of Federal and State natural resource trustees of potential damages to natural resources under investigation and requires coordination of the assessments, investigations...
43 CFR 11.20 - Notification and detection.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 11.20 Public Lands: Interior Office of the Secretary of the Interior NATURAL RESOURCE DAMAGE... CERCLA requires prompt notification of Federal and State natural resource trustees of potential damages to natural resources under investigation and requires coordination of the assessments, investigations...
Gómez-Tello, V; Latour-Pérez, J; Añón Elizalde, J M; Palencia-Herrejón, E; Díaz-Alersi, R; De Lucas-García, N
2006-01-01
Estimate knowledge and use habits of different electronic resources in a sample of Spanish intensivists: Internet, E-mail, distribution lists, and use of portable electronic devices. Self-applied questionnaire. A 50-question questionnaire was distributed among Spanish intensivists through the hospital marketing delegates of a pharmaceutical company and of electronic forums. A total of 682 questionnaires were analyzed (participation: 74%). Ninety six percent of those surveyed used Internet individually: 67% admitted training gap. Internet was the second source of clinical consultations most used (61%), slightly behind consultation to colleagues (65%). The pages consulted most were bibliographic databases (65%) and electronic professional journals (63%), with limited use of Evidence Based Medicine pages (19%). Ninety percent of those surveyed used e-mail regularly in the practice of their profession, although 25% admitted that were not aware of its possibilities. The use of E-mail decreased significantly with increase in age. A total of 62% of the intensivists used distribution lists. Of the rest, 42% were not aware of its existence and 32% admitted they had insufficient training to handle them. Twenty percent of those surveyed had portable electronic devices and 64% considered it useful, basically due to its rapid consultation at bedside. Female gender was a negative predictive factor of its use (OR 0.35; 95% CI 0.2-0.63; p=0.0002). A large majority of the Spanish intensivists use Internet and E-mail. E-mail lists and use of portable devices are still underused resources. There are important gaps in training and infrequent use of essential pages. There are specific groups that require directed educational policies.
Randomised controlled trial of intrapartum fetal heart rate monitoring.
Mahomed, K; Nyoni, R; Mulambo, T; Kasule, J; Jacobus, E
1994-02-19
To compare effectiveness of different methods of monitoring intrapartum fetal heart rate. Prospective randomised controlled trial. Referral maternity hospital, Harare, Zimbabwe. 1255 women who were 37 weeks or more pregnant with singleton cephalic presentation and normal fetal heart rate before entry into study. Intermittent monitoring of fetal heart rate by electronic monitoring, Doppler ultrasound, use of Pinard stethoscope by a research midwife, or routine use of Pinard stethoscope by attending midwife. Abnormal fetal heart rate patterns, need for operative delivery for fetal distress, neonatal mortality, Apgar scores, admission to neonatal unit, neonatal seizures, and hypoxic ischaemic encephalopathy. Abnormalities in fetal heart rate were detected in 54% (172/318) of the electronic monitoring group, 32% (100/312) of the ultrasonography group, 15% (47/310) of the Pinard stethoscope group, and 9% (28/315) of the routine monitoring group. Caesarean sections were performed for 28% (89%), 24% (76), 10% (32), and 15% (46) of the four groups respectively. Neonatal outcome was best in the ultrasonography group: hypoxic ischaemic encephalopathy occurred in two, one, seven, and 10 cases in the four groups respectively; neonatal seizures occurred only in the last two groups (six and nine cases respectively); and deaths occurred in eight, two, five, and nine cases respectively. Abnormalities in fetal heart rate were more reliably detected by Doppler ultrasonography than with Pinard stethoscope, and its use resulted in good perinatal outcome. The use of relatively cheap ultrasound monitors should be further evaluated and promoted in obstetric units caring for high risk pregnancies in developing countries with scarce resources.
Randomised controlled trial of intrapartum fetal heart rate monitoring.
Mahomed, K.; Nyoni, R.; Mulambo, T.; Kasule, J.; Jacobus, E.
1994-01-01
OBJECTIVE--To compare effectiveness of different methods of monitoring intrapartum fetal heart rate. DESIGN--Prospective randomised controlled trial. SETTING--Referral maternity hospital, Harare, Zimbabwe. SUBJECTS--1255 women who were 37 weeks or more pregnant with singleton cephalic presentation and normal fetal heart rate before entry into study. INTERVENTIONS--Intermittent monitoring of fetal heart rate by electronic monitoring, Doppler ultrasound, use of Pinard stethoscope by a research midwife, or routine use of Pinard stethoscope by attending midwife. MAIN OUTCOME MEASURES--Abnormal fetal heart rate patterns, need for operative delivery for fetal distress, neonatal mortality, Apgar scores, admission to neonatal unit, neonatal seizures, and hypoxic ischaemic encephalopathy. RESULTS--Abnormalities in fetal heart rate were detected in 54% (172/318) of the electronic monitoring group, 32% (100/312) of the ultrasonography group, 15% (47/310) of the Pinard stethoscope group, and 9% (28/315) of the routine monitoring group. Caesarean sections were performed for 28% (89%), 24% (76), 10% (32), and 15% (46) of the four groups respectively. Neonatal outcome was best in the ultrasonography group: hypoxic ischaemic encephalopathy occurred in two, one, seven, and 10 cases in the four groups respectively; neonatal seizures occurred only in the last two groups (six and nine cases respectively); and deaths occurred in eight, two, five, and nine cases respectively. CONCLUSIONS--Abnormalities in fetal heart rate were more reliably detected by Doppler ultrasonography than with Pinard stethoscope, and its use resulted in good perinatal outcome. The use of relatively cheap ultrasound monitors should be further evaluated and promoted in obstetric units caring for high risk pregnancies in developing countries with scarce resources. PMID:8136665
Cardiac Implantable Electronic Device Interrogation at Forensic Autopsy: An Underestimated Resource?
Lacour, Philipp; Buschmann, Claas; Storm, Christian; Nee, Jens; Parwani, Abdul Shokor; Huemer, Martin; Attanasio, Philipp; Boldt, Leif-Hendrik; Rauch, Geraldine; Kucher, Andreas; Pieske, Burkert; Haverkamp, Wilhelm; Blaschke, Florian
2018-06-19
Postmortem interrogations of cardiac implantable electronic devices (CIEDs), recommended at autopsy in suspected cases of sudden cardiac death, are rarely performed, and data on systematic postmortem CIED analysis in the forensic pathology are missing. The aim of the study was to determine whether nonselective postmortem CIED interrogations and data analysis are useful to the forensic pathologist to determine the cause, mechanism, and time of death and to detect potential CIED-related safety issues. From February 2012 to April 2017, all autopsy subjects in the department of forensic medicine at the University Hospital Charité who had a CIED underwent device removal and interrogation. Over the study period, 5368 autopsies were performed. One hundred fifty subjects had in total 151 CIEDs, including 109 pacemakers, 35 defibrillators, and 7 implantable loop recorders. In 40 cases (26.7%) time of death and in 51 cases (34.0%) cause of death could not be determined by forensic autopsy. Of these, CIED interrogation facilitated the determination of time of death in 70.0% of the cases and clarified the cause of death in 60.8%. Device concerns were identified in 9 cases (6.0%), including 3 hardware, 4 programming, and 2 algorithm issues. One CIED was submitted to the manufacturer for a detailed technical analysis. Our data demonstrate the necessity of systematic postmortem CIED interrogation in forensic medicine to determine the cause and timing of death more accurately. In addition, CIED analysis is an important tool to detect potential CIED-related safety issues. © 2018 American Heart Association, Inc.
Diagnosis of fetal syndromes by three- and four-dimensional ultrasound: is there any improvement?
Barišić, Lara Spalldi; Stanojević, Milan; Kurjak, Asim; Porović, Selma; Gaber, Ghalia
2017-08-28
With all of our present knowledge, high technology diagnostic equipment, electronic databases and other available supporting resources, detection of fetal syndromes is still a challenge for healthcare providers in prenatal as well as in the postnatal period. Prenatal diagnosis of fetal syndromes is not straightforward, and it is a difficult puzzle that needs to be assembled and solved. Detection of one anomaly should always raise a suspicion of the existence of more anomalies, and can be a trigger to investigate further and raise awareness of possible syndromes. Highly specialized software systems for three- and four-dimensional ultrasound (3D/4D US) enabled detailed depiction of fetal anatomy and assessment of the dynamics of fetal structural and functional development in real time. With recent advances in 3D/4D US technology, antenatal diagnosis of fetal anomalies and syndromes shifted from the 2nd to the 1st trimester of pregnancy. It is questionable what can and should be done after the prenatal diagnosis of fetal syndrome. The 3D and 4D US techniques improved detection accuracy of fetal abnormalities and syndromes from early pregnancy onwards. It is not easy to make prenatal diagnosis of fetal syndromes, so tools which help like online integrated databases are needed to increase diagnostic precision. The aim of this paper is to present the possibilities of different US techniques in the detection of some fetal syndromes prenatally.
NASA Technical Reports Server (NTRS)
Boumsellek, S.; Alajajian, S. H.; Chutjian, A.
1992-01-01
First results of a beam-beam, single-collision study of negative-ion mass spectra produced by attachment of zero-energy electrons to the molecules of the explosives RDX, PETN, and TNT are presented. The technique used is reversal electron attachment detection (READ) wherein the zero-energy electrons are produced by focusing an intense electron beam into a shaped electrostatic field which reverses the trajectory of electrons. The target beam is introduced at the reversal point, and attachment occurs because the electrons have essentially zero longitudinal and radial velocity. The READ technique is used to obtain the 'signature' of molecular ion formation and/or fragmentation for each explosive. Present data are compared with results from atmospheric-pressure ionization and negative-ion chemical ionization methods.
Porous material neutron detector
Diawara, Yacouba [Oak Ridge, TN; Kocsis, Menyhert [Venon, FR
2012-04-10
A neutron detector employs a porous material layer including pores between nanoparticles. The composition of the nanoparticles is selected to cause emission of electrons upon detection of a neutron. The nanoparticles have a maximum dimension that is in the range from 0.1 micron to 1 millimeter, and can be sintered with pores thereamongst. A passing radiation generates electrons at one or more nanoparticles, some of which are scattered into a pore and directed toward a direction opposite to the applied electrical field. These electrons travel through the pore and collide with additional nanoparticles, which generate more electrons. The electrons are amplified in a cascade reaction that occurs along the pores behind the initial detection point. An electron amplification device may be placed behind the porous material layer to further amplify the electrons exiting the porous material layer.
Finding alternatives when a major database is gone*
Hu, Estelle
2016-01-01
Question What to do when a major database ceases publication? Setting An urban, academic health sciences library with four campuses serves a university health sciences system, a college of medicine, and five other health sciences colleges. Methods Usage statistics of each e-book title in the resource were carefully analyzed. Purchase decisions were made based on the assessment of usage. Results Sustainable resources were acquired from other vendors, with perpetual access for library users. Conclusion This systematic process of finding alternative resources is an example of librarians' persistence in acquiring perpetual electronic resources when a major resource is cancelled. PMID:27076804
DOE Office of Scientific and Technical Information (OSTI.GOV)
Villis, B. J.; Sanquer, M.; Jehl, X.
2014-06-09
The continuous downscaling of transistors results in nanoscale devices which require fewer and fewer charged carriers for their operation. The ultimate charge controlled device, the single-electron transistor (SET), controls the transfer of individual electrons. It is also the most sensitive electrometer, and as a result the electron transport through it can be dramatically affected by nearby charges. Standard direct-current characterization techniques, however, are often unable to unambiguously detect and resolve the origin of the observed changes in SET behavior arising from changes in the charge state of a capacitively coupled trap. Using a radio-frequency (RF) reflectometry technique, we are ablemore » to unequivocally detect this process, in very close agreement with modeling of the trap's occupation probability.« less
Tenenbaum, Jessica D.; Whetzel, Patricia L.; Anderson, Kent; Borromeo, Charles D.; Dinov, Ivo D.; Gabriel, Davera; Kirschner, Beth; Mirel, Barbara; Morris, Tim; Noy, Natasha; Nyulas, Csongor; Rubenson, David; Saxman, Paul R.; Singh, Harpreet; Whelan, Nancy; Wright, Zach; Athey, Brian D.; Becich, Michael J.; Ginsburg, Geoffrey S.; Musen, Mark A.; Smith, Kevin A.; Tarantal, Alice F.; Rubin, Daniel L; Lyster, Peter
2010-01-01
The biomedical research community relies on a diverse set of resources, both within their own institutions and at other research centers. In addition, an increasing number of shared electronic resources have been developed. Without effective means to locate and query these resources, it is challenging, if not impossible, for investigators to be aware of the myriad resources available, or to effectively perform resource discovery when the need arises. In this paper, we describe the development and use of the Biomedical Resource Ontology (BRO) to enable semantic annotation and discovery of biomedical resources. We also describe the Resource Discovery System (RDS) which is a federated, inter-institutional pilot project that uses the BRO to facilitate resource discovery on the Internet. Through the RDS framework and its associated Biositemaps infrastructure, the BRO facilitates semantic search and discovery of biomedical resources, breaking down barriers and streamlining scientific research that will improve human health. PMID:20955817
N-mix for fish: estimating riverine salmonid habitat selection via N-mixture models
Som, Nicholas A.; Perry, Russell W.; Jones, Edward C.; De Juilio, Kyle; Petros, Paul; Pinnix, William D.; Rupert, Derek L.
2018-01-01
Models that formulate mathematical linkages between fish use and habitat characteristics are applied for many purposes. For riverine fish, these linkages are often cast as resource selection functions with variables including depth and velocity of water and distance to nearest cover. Ecologists are now recognizing the role that detection plays in observing organisms, and failure to account for imperfect detection can lead to spurious inference. Herein, we present a flexible N-mixture model to associate habitat characteristics with the abundance of riverine salmonids that simultaneously estimates detection probability. Our formulation has the added benefits of accounting for demographics variation and can generate probabilistic statements regarding intensity of habitat use. In addition to the conceptual benefits, model application to data from the Trinity River, California, yields interesting results. Detection was estimated to vary among surveyors, but there was little spatial or temporal variation. Additionally, a weaker effect of water depth on resource selection is estimated than that reported by previous studies not accounting for detection probability. N-mixture models show great promise for applications to riverine resource selection.
Continuing Education for E-Resources
ERIC Educational Resources Information Center
Grogg, Jill E.
2008-01-01
Library schools may be teaching some of the theoretical framework necessary to perform the duties of electronic resource librarianship. However, a gap remains "between practical needs, as expressed in position descriptions, and the theoretical way in which library school courses address those needs." To fill this gap, professional associations…
The Internet Compendium: Subject Guides to Humanities Resources.
ERIC Educational Resources Information Center
Rosenfeld, Louis; And Others
This guide describes and evaluates the Internet's humanities resources by subject. It offers information on a multitude of listservs; Usenet newsgroups; forums; electronic journals; topical mailing lists; text archives; Freenets; bulletin boards; FAQs; newsletters; real-time chats; databases; and library catalogs. Internet users can draw upon…
Reading the 'Net--Books in Cyberspace.
ERIC Educational Resources Information Center
Foster, Janet
1999-01-01
Discusses electronic text collections, bookstores on the Web, reader advisories, cyber book reviews, and resources for librarians explaining how to locate online reading materials. Suggests that librarians can exploit online book resources to complement current collection-development strategies or use them as virtual reader's advisories. Cites 17…
Electronic Resources for Youth Services: A Print Bibliography and Web Site.
ERIC Educational Resources Information Center
Amey, Larry; Segal, Erez
1996-01-01
This article evaluates 57 World Wide Web sites related to children's literature and youth-oriented library services, in categories including award-winning books; book reviews; reading and storytelling; writing resources; online children's literature; educational entertainment; and authors, publishers, and booksellers. Also included is information…
Monitoring aquatic resources for regional assessments requires an accurate and comprehensive inventory of the resource and useful classification of exosystem similarities. Our research effort to create an electronic database and work with various ways to classify coastal wetlands...
Method and apparatus for measuring purity of noble gases
Austin, Robert
2008-04-01
A device for detecting impurities in a noble gas includes a detection chamber and a source of pulsed ultraviolet light. The pulse of the ultraviolet light is transferred into the detection chamber and onto a photocathode, thereby emitting a cloud of free electrons into the noble gas within the detection chamber. The cloud of electrons is attracted to the opposite end of the detection chamber by a high positive voltage potential at that end and focused onto a sensing anode. If there are impurities in the noble gas, some or all of the electrons within the cloud will bond with the impurity molecules and not reach the sensing anode. Therefore, measuring a lower signal at the sensing anode indicates a higher level of impurities while sensing a higher signal indicates fewer impurities. Impurities in the range of one part per billion can be measured by this device.
NASA Astrophysics Data System (ADS)
Pujiyanto; Yasin, M.; Rusydi, F.
2018-03-01
Development of lead ion detection systems is expected to have an advantage in terms of simplicity of the device and easy for concentration analysis of a lead ion with very high performance. One important part of lead ion detection systems are electrical signal acquisition parts. The electrical signal acquisition part uses the main electronic components: non inverting op-amplifier, instrumentation amplifier, multiplier circuit and logarithmic amplifier. Here will be shown the performance of lead ion detection systems when the existing electrical signal processors use commercial electronic components. The results that can be drawn from this experimental were the lead ion sensor that has been developed can be used to detect lead ions with a sensitivity of 10.48 mV/ppm with the linearity 97.11% and had a measurement range of 0.1 ppm to 80 ppm.
ERIC Educational Resources Information Center
Helal, Ahmed H., Ed.; Weiss, Joachim W.
This proceedings includes the following papers presented at the 16th International Essen Symposium: "Electronic Resource Sharing: It May Seem Obvious, But It's Not as Simple as it Looks" (Herbert S. White); "Resource Sharing through OCLC: A Comprehensive Approach" (Janet Mitchell); "The Business Information Network:…
2012-12-14
technology that comprises the Internet. Among them are aluminum, antimony, barium, cadmium , chromium, copper, gold, iron, lead , mercury, platinum...dependence. This may lead to resource conflict as nations continue their pursuit of prosperity and security. National leaders will inevitably change or adopt... mineral resources associated with computerization and advanced electronics will markedly increase in their strategic relative importance. This
Sustaining "meaningful use" of health information technology in low-resource practices.
Green, Lee A; Potworowski, Georges; Day, Anya; May-Gentile, Rachelle; Vibbert, Danielle; Maki, Bruce; Kiesel, Leslie
2015-01-01
The implementation of electronic health records (EHRs) has been extensively studied, but their maintenance once implemented has not. The Regional Extension Center (REC) program provides implementation assistance to priority practices-those with limited financial, technical, and organizational resources-but the assistance is time limited. Our objective was to identify potential barriers to maintenance of meaningful use of EHRs in priority primary care practices using a qualitative observational study for federally qualified health centers (FQHCs) and priority practices in Michigan. We conducted cognitive task analysis (CTA) interviews and direct observations of health information technology implementation in FQHCs. In addition, we conducted semistructured interviews with implementation specialists serving priority practices to detect emergent themes relevant to maintenance. Maintaining EHR technology will require ongoing expert technical support indefinitely beyond implementation to address upgrades and security needs. Maintaining meaningful use for quality improvement will require ongoing support for leadership and change management. Priority practices not associated with larger systems lack access to the necessary technical expertise, financial resources, and leverage with vendors to continue alone. Rural priority practices are particularly challenged, because expertise is often not available locally. Priority practices, especially in rural areas, are at high risk for falling on the wrong side of a "digital divide" as payers and regulators enact increasing expectations for EHR use and information management. For those without affiliation to maintain the necessary expert staff, ongoing support will be needed for those practices to remain viable. © 2015 Annals of Family Medicine, Inc.
An evaluation of immunization education resources by family medicine residency directors.
Nowalk, Mary Patricia; Zimmerman, Richard K; Middleton, Donald B; Sherwood, Roger A; Ko, Feng-Shou; Kimmel, Sanford R; Troy, Judith A
2007-01-01
Immunization is a rapidly evolving field, and teachers of family medicine are responsible for ensuring that they and their students are knowledgeable about the latest vaccine recommendations. A survey was mailed to 456 family medicine residency directors across the United States to obtain their evaluation of immunization resources developed by the Society of Teachers of Family Medicine's Group on Immunization Education. Frequencies, measures of central tendency, and differences between responses from 2001 to 2005 were analyzed. Directors of 261 (57%) family medicine residencies responded, with >80% reporting satisfaction with immunization teaching resources. The popularity of bound resources decreased from 2001 to 2005, while immunization Web sites increased in importance. The journal supplement, "Vaccines Across the Lifespan, 2005" was less frequently read in 2005 than its predecessor published in 2001, but quality ratings remained high. Use of the Web site, www.ImmunizationEd.org, and the Shots software for both desktop and handheld computers has increased since their creation. Electronic immunization teaching resources are increasingly popular among family medicine residencies. As the field continues to change, the use of electronic resources is expected to continue, since they are easily updated and, in the case of www.ImmunizationEd.org and Shots software, are available free of charge.
Mayer, Susanne; Paulus, Aggie T G; Łaszewska, Agata; Simon, Judit; Drost, Ruben M W A; Ruwaard, Dirk; Evers, Silvia M A A
2017-09-01
Intersectoral costs and benefits (ICBs), i.e. costs and benefits of healthcare interventions outside the healthcare sector, can be a crucial component in economic evaluations from the societal perspective. Pivotal to their estimation is the existence of sound resource-use measurement (RUM) instruments; however, RUM instruments for ICBs in the education or criminal justice sectors have not yet been systematically collated or their psychometric quality assessed. This review aims to fill this gap. To identify relevant instruments, the Database of Instruments for Resource Use Measurement (DIRUM) was searched. Additionally, a systematic literature review was conducted in seven electronic databases to detect instruments containing ICB items used in economic evaluations. Finally, studies evaluating the psychometric quality of these instruments were searched. Twenty-six unique instruments were included. Most frequently, ICB items measured school absenteeism, tutoring, classroom assistance or contacts with legal representatives, police custody/prison detainment and court appearances, with the highest number of items listed in the Client Service Receipt Inventory/Client Sociodemographic and Service Receipt Inventory/Client Service Receipt Inventory-Children's Version (CSRI/CSSRI/CSRI-C), Studying the Scope of Parental Expenditures (SCOPE) and Self-Harm Intervention, Family Therapy (SHIFT) instruments. ICBs in the education sector were especially relevant for age-related developmental disorders and chronic diseases, while criminal justice resource use seems more important in mental health, including alcohol-related disorders or substance abuse. Evidence on the validity or reliability of ICB items was published for two instruments only. With a heterogeneous variety of ICBs found to be relevant for several disease areas but many ICB instruments applied in one study only (21/26 instruments), setting-up an international task force to, for example, develop an internationally adaptable instrument is recommended.
NASA Astrophysics Data System (ADS)
Bokov, A. V.; Byakov, V. M.; Kulikov, L. A.; Perfiliev, Yu. D.; Stepanov, S. V.
2017-11-01
Being the main cause of cancer, almost all chemical carcinogens are strong electrophiles, that is, they have a high affinity for the electron. We have shown that positron annihilation lifetime spectroscopy (PALS) is able to detect chemical carcinogens by their inhibition of positronium (Ps) formation in liquid media. Electrophilic carcinogens intercept thermalized track electrons, which are precursors of Ps, and as a result, when they are present Ps atom does not practically form. Available biophysical data seemingly indicate that frozen solutions model better an intracellular medium than the liquid ones. So it is reasonable to use emission Mössbauer spectroscopy (EMS) to detect chemical carcinogens, measuring the yield of 57Fe2+ions formed in reactions of Auger electrons and other secondary electrons they produced with 57Fe3+. These reactions are similar to the Ps formation process in the terminal part the positron track: e++ e- =>Ps. So EMS and PALS are complementary methods for detection of carcinogenic compounds.
ERIC Educational Resources Information Center
Jackson, Mary E.
1998-01-01
Assesses the changes in interlibrary loan (ILL) practices, and points the way to an ideal future. Discusses patron-initiated document request systems; library-mediated ordering systems; document delivery suppliers; accessing electronic resources; ILL management software; paying ILL invoices; new electronic delivery options; and results of a…
Teachers and Electronic Mail: Networking on the Network.
ERIC Educational Resources Information Center
Broholm, John R.; Aust, Ronald
1994-01-01
Describes a study that examined the communication patterns of teachers who used UNITE (Unified Network for Informatics in Teacher Education), an electronic mail system designed to encourage curricular collaboration and resource sharing. Highlights include computer-mediated communication, use of UNITE by librarians, and recommendations for…
Russo, P L; Shaban, R Z; Macbeth, D; Carter, A; Mitchell, B G
2018-05-01
Surveillance of healthcare-associated infections is fundamental for infection prevention. The methods and practices for surveillance have evolved as technology becomes more advanced. The availability of electronic surveillance software (ESS) has increased, and yet adoption of ESS is slow. It is argued that ESS delivers savings through automation, particularly in terms of human resourcing and infection prevention (IP) staff time. To describe the findings of a systematic review on the impact of ESS on IP resources. A systematic search was conducted of electronic databases Medline and the Cumulative Index to Nursing and Allied Health Literature published between January 1 st , 2006 and December 31 st , 2016 with analysis using the Newcastle-Ottawa Scale. In all, 2832 articles were reviewed, of which 16 studies met the inclusion criteria. IP resources were identified as time undertaken on surveillance. A reduction in IP staff time to undertake surveillance was demonstrated in 13 studies. The reduction proportion ranged from 12.5% to 98.4% (mean: 73.9%). The remaining three did not allow for any estimation of the effect in terms of IP staff time. None of the studies demonstrated an increase in IP staff time. The results of this review demonstrate that adopting ESS yields considerable dividends in IP staff time relating to data collection and case ascertainment while maintaining high levels of sensitivity and specificity. This has the potential to enable reinvestment into other components of IP to maximize efficient use of scarce IP resources. Copyright © 2017 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.
NASA Earth Resources Survey Symposium. Volume 1-D: Water resources
NASA Technical Reports Server (NTRS)
1975-01-01
Conference papers on water resources and management are summarized. Summaries cover land use, flood control and prediction, watersheds and the effects of snow melt, soil moisture content, and the usefulness of satellite remote sensors in detecting ground and surface water.
NASA Technical Reports Server (NTRS)
Marshburn, Thomas; Cole, Richard; Ebert, Doug; Bauer, Pete
2014-01-01
Introduction: Evaluation of heart, lung, and bowel sounds is routinely performed with the use of a stethoscope to help detect a broad range of medical conditions. Stethoscope acquired information is even more valuable in a resource limited environments such as the International Space Station (ISS) where additional testing is not available. The high ambient noise level aboard the ISS poses a specific challenge to auscultation by stethoscope. An electronic stethoscope's ambient noise-reduction, greater sound amplification, recording capabilities, and sound visualization software may be an advantage to a conventional stethoscope in this environment. Methods: A single operator rated signal-to-noise quality from a conventional stethoscope (Littman 2218BE) and an electronic stethoscope (Litmann 3200). Borborygmi, pulmonic, and cardiac sound quality was ranked with both stethoscopes. Signal-to-noise rankings were preformed on a 1 to 10 subjective scale with 1 being inaudible, 6 the expected quality in an emergency department, 8 the expected quality in a clinic, and 10 the clearest possible quality. Testing took place in the Japanese Pressurized Module (JPM), Unity (Node 2), Destiny (US Lab), Tranquility (Node 3), and the Cupola of the International Space Station. All examinations were conducted at a single point in time. Results: The electronic stethoscope's performance ranked higher than the conventional stethoscope for each body sound in all modules tested. The electronic stethoscope's sound quality was rated between 7 and 10 in all modules tested. In comparison, the traditional stethoscope's sound quality was rated between 4 and 7. The signal to noise ratio of borborygmi showed the biggest difference between stethoscopes. In the modules tested, the auscultation of borborygmi was rated between 5 and 7 by the conventional stethoscope and consistently 10 by the electronic stethoscope. Discussion: This stethoscope comparison was limited to a single operator. However, we believe the results are noteworthy. The electronic stethoscope out preformed the traditional stethoscope in each direct comparison. Consideration should be made to incorporate an electronic stethoscope into current and future space vehicle medical kits.
Nano-Electromechanical Systems: Displacement Detection and the Mechanical Single Electron Shuttle
NASA Astrophysics Data System (ADS)
Blick, R. H.; Beil, F. W.; Höhberger, E.; Erbe, A.; Weiss, C.
For an introduction to nano-electromechanical systems we present measurements on nanomechanical resonators operating in the radio frequency range. We discuss in detail two different schemes of displacement detection for mechanical resonators, namely conventional reflection measurements of a probing signal and direct detection by capacitive coupling via a gate electrode. For capacitive detection we employ an on-chip preamplifier, which enables direct measurements of the resonator's disp lacement. We observe that the mechanical quality factor of the resonator depends on the detection technique applied, which is verified in model calculations and report on the detection of sub-harmonics. In the second part we extend our investigations to include transport of single electrons through an electron island on the tip of a nanomachined mechanical pendulum. The pendulum is operated by applying a modulating electromagnetic field in the range of 1 - 200 MHz, leading to mechanical oscillations between two laterally integrated source and drain contacts. Forming tunneling barriers the metallic tip shuttles single electrons from source to drain. The resulting tunneling current shows distinct features corresponding to the discrete mechanical eigenfrequencies of the pendulum. We report on measurements covering the temperature range from 300 K down to 4.2 K. The transport properties of the device are compared in detail to model calculations based on a Master-equation approach.
Linear electronic field time-of-flight ion mass spectrometers
Funsten, Herbert O.
2010-08-24
Time-of-flight mass spectrometer comprising a first drift region and a second drift region enclosed within an evacuation chamber; a means of introducing an analyte of interest into the first drift region; a pulsed ionization source which produces molecular ions from said analyte of interest; a first foil positioned between the first drift region and the second drift region, which dissociates said molecular ions into constituent atomic ions and emits secondary electrons; an electrode which produces secondary electrons upon contact with a constituent atomic ion in second drift region; a stop detector comprising a first ion detection region and a second ion detection region; and a timing means connected to the pulsed ionization source, to the first ion detection region, and to the second ion detection region.
Detection of New Dissociative Electron Attachment Channels in NO
NASA Technical Reports Server (NTRS)
Orient, O. J.; Chutjian, A.
1995-01-01
Three dissociative electron attachment channels have been detected and identified in NO via measurement of the O minus (exp 2)P fragment energy. In addition to the known N((exp 2 D(exp 0)) + O minus (exp 2)P channel, two new channels N((exp 1 S(exp 0)) + 0 (2 P) and N(exp 2)P(exp 0) + O(exp 2)P were detected. Cross sections for each of the channels are reported by normalizing the scattering intensities to previously measured total cross sections. The experimental approach uses solenoidal magnetic confinement of the electrons and ions, and trochoidal energy analysis of the low-energy ions.
Probability of detection of defects in coatings with electronic shearography
NASA Astrophysics Data System (ADS)
Maddux, Gary A.; Horton, Charles M.; Lansing, Matthew D.; Gnacek, William J.; Newton, Patrick L.
1994-07-01
The goal of this research was to utilize statistical methods to evaluate the probability of detection (POD) of defects in coatings using electronic shearography. The coating system utilized in the POD studies was to be the paint system currently utilized on the external casings of the NASA Space Transportation System (STS) Revised Solid Rocket Motor (RSRM) boosters. The population of samples was to be large enough to determine the minimum defect size for 90 percent probability of detection of 95 percent confidence POD on these coatings. Also, the best methods to excite coatings on aerospace components to induce deformations for measurement by electronic shearography were to be determined.
Leiker, Thomas J.; Madsen, J.E.; Deacon, J.R.; Foreman, W.T.
1995-01-01
A method for the determination of chlorinated organic compounds in aquatic tissue by dual capillary-column gas chromatography with electron-capture detection is described. Whole-body-fish or corbicula tissue is homogenized, Soxhlet extracted, lipid removed by gel permeation chromatography, and fractionated using alumina/silica adsorption chromatography. The extracts are analyzed by dissimilar capillary-column gas chromatography with electron-capture detection. The method reporting limits are 5 micrograms per kilogram (μg/kg) for chlorinated compounds, 50 μg/kg for polychlorinated biphenyls, and 200 μg/kg for toxaphene.
Probability of detection of defects in coatings with electronic shearography
NASA Technical Reports Server (NTRS)
Maddux, Gary A.; Horton, Charles M.; Lansing, Matthew D.; Gnacek, William J.; Newton, Patrick L.
1994-01-01
The goal of this research was to utilize statistical methods to evaluate the probability of detection (POD) of defects in coatings using electronic shearography. The coating system utilized in the POD studies was to be the paint system currently utilized on the external casings of the NASA Space Transportation System (STS) Revised Solid Rocket Motor (RSRM) boosters. The population of samples was to be large enough to determine the minimum defect size for 90 percent probability of detection of 95 percent confidence POD on these coatings. Also, the best methods to excite coatings on aerospace components to induce deformations for measurement by electronic shearography were to be determined.
The Internet Compendium: Subject Guides to Health and Science Resources.
ERIC Educational Resources Information Center
Rosenfeld, Louis; And Others
This guide describes and evaluates the Internet's health and science resources by subject. It offers information on a multitude of listservs; Usenet newsgroups; forums; electronic journals; topical mailing lists; text archives; Freenets; bulletin boards; FAQs; newsletters; real-time chats; databases; and library catalogs. From alternative medicine…
Atmospheric Sciences Information Resources in the United States--An Overview for Librarians.
ERIC Educational Resources Information Center
Layman, Mary; Smith, Shirley
1993-01-01
Presents an overview of the types of information and information sources available in the field of atmospheric sciences. Included are major library collections; organizations; government programs, including air pollution control regulations; electronic databases; and networking resources. Addresses are provided for all sources, and definitions of…
Cloud Computing and Your Library
ERIC Educational Resources Information Center
Mitchell, Erik T.
2010-01-01
One of the first big shifts in how libraries manage resources was the move from print-journal purchasing models to database-subscription and electronic-journal purchasing models. Libraries found that this transition helped them scale their resources and provide better service just by thinking a bit differently about their services. Likewise,…
76 FR 35900 - Agency Information Collection Activities: Proposed Collection: Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-20
... few new questions will be asked about health center Electronic Health Record reporting capabilities... DEPARTMENT OF HEALTH AND HUMAN SERVICES Health Resources and Services Administration Agency... States Code, as amended by the Paperwork Reduction Act of 1995, Pub. L. 104-13), the Health Resources and...
Resources for Family and Consumer Science Teachers, 1995.
ERIC Educational Resources Information Center
Scholl, Jan
This annotated bibliography of resources for family and consumer science teachers lists 59 items developed for "Teacher Pages" (an electronic information service) by Penn State Cooperative Extension Service between December 1, 1993 and December 1, 1994. Each listing includes a short description, source, address, price if appropriate, and ordering…
School Building Design and Audio-Visual Resources.
ERIC Educational Resources Information Center
National Committee for Audio-Visual Aids in Education, London (England).
The design of new schools should facilitate the use of audiovisual resources by ensuring that the materials used in the construction of the buildings provide adequate sound insulation and acoustical and viewing conditions in all learning spaces. The facilities to be considered are: electrical services; electronic services; light control and…
Internet-Accessible Scholarly Resources for the Humanities and Social Sciences.
ERIC Educational Resources Information Center
ACLS Newsletter, 1997
1997-01-01
This newsletter focuses on the presentations of a program session on Internet-accessible scholarly resources, held at the 1996 ACLS Annual Meeting. Articles in the newsletter include: "Building the Scene: Words, Images, Data, and Beyond" (David Green); "Electronic Texts: The Promise and the Reality" (Susan Hockey); "Images…
USDA-ARS?s Scientific Manuscript database
Many of the world's national genebanks, responsible for the safeguarding and availability of their country's Plant Genetic Resource (PGR) collections, have lacked access to high quality IT needed to document and manage their collections electronically. The Germplasm Resource Information System (GRI...
Florida Information Resource Network.
ERIC Educational Resources Information Center
Watson, Francis C.
1986-01-01
The Florida Information Resource Network (FIRN) is an effort by the Florida education community and the Florida Legislature to provide an electronic link among all agencies, institutions, and schools in the public education system. The communications link, perhaps one of the most advanced in the nation, has three purposes: (1) to provide equal…
Internet Resources on Aging: Parts of the Internet.
ERIC Educational Resources Information Center
Post, Joyce A.
1996-01-01
Provides a brief history of the Internet and a listing of various resources on aging that can be obtained through the Internet. Components of the Internet discussed are electronic-mail applications (listservs, USENET Newsgroups, Bulletin Board Systems, Freenets, and Commercial Services); File Transfer Protocol; Telnet/Remote Login; Gophers; Wide…
ERIC Educational Resources Information Center
Kleiner, Jane P.; Hamaker, Charles A.
1997-01-01
Describes three projects at Louisiana State University libraries designed to utilize document delivery and electronic access to expand collections, identify faculty journal needs, and share resources among academic, public, special, and school libraries. Network developments, grant support, and needs assessment surveys are also discussed.…
Solar system lithograph set for earth and space science
NASA Technical Reports Server (NTRS)
1995-01-01
A color lithographs of many of the celestial bodies within our solar system are contained in this educational set of materials. Printed on the back of each lithograph is information regarding the particular celestial body. A sheet with information listing NASA resources and electronic resources for education is included.
Single-electron detection and spectroscopy via relativistic cyclotron radiation
Asner, D. M.; Bradley, R. F.; de Viveiros, L.; ...
2015-04-20
Since 1897, we've understood that accelerating charges must emit electromagnetic radiation. Cyclotron radiation, the particular form of radiation emitted by an electron orbiting in a magnetic field, was first derived in 1904. Despite the simplicity of this concept, and the enormous utility of electron spectroscopy in nuclear and particle physics, single-electron cyclotron radiation has never been observed directly. We demonstrate single-electron detection in a novel radiofrequency spec- trometer. Here, we observe the cyclotron radiation emitted by individual magnetically-trapped electrons that are produced with mildly-relativistic energies by a gaseous radioactive source. The relativistic shift in the cyclotron frequency permits a precisemore » electron energy measurement. Precise beta electron spectroscopy from gaseous radiation sources is a key technique in modern efforts to measure the neutrino mass via the tritium decay endpoint, and this work demonstrates a fundamentally new approach to precision beta spectroscopy for future neutrino mass experiments.« less
Methods, media, and systems for detecting attack on a digital processing device
Stolfo, Salvatore J.; Li, Wei-Jen; Keromylis, Angelos D.; Androulaki, Elli
2014-07-22
Methods, media, and systems for detecting attack are provided. In some embodiments, the methods include: comparing at least part of a document to a static detection model; determining whether attacking code is included in the document based on the comparison of the document to the static detection model; executing at least part of the document; determining whether attacking code is included in the document based on the execution of the at least part of the document; and if attacking code is determined to be included in the document based on at least one of the comparison of the document to the static detection model and the execution of the at least part of the document, reporting the presence of an attack. In some embodiments, the methods include: selecting a data segment in at least one portion of an electronic document; determining whether the arbitrarily selected data segment can be altered without causing the electronic document to result in an error when processed by a corresponding program; in response to determining that the arbitrarily selected data segment can be altered, arbitrarily altering the data segment in the at least one portion of the electronic document to produce an altered electronic document; and determining whether the corresponding program produces an error state when the altered electronic document is processed by the corresponding program.
Methods, media, and systems for detecting attack on a digital processing device
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stolfo, Salvatore J.; Li, Wei-Jen; Keromytis, Angelos D.
Methods, media, and systems for detecting attack are provided. In some embodiments, the methods include: comparing at least part of a document to a static detection model; determining whether attacking code is included in the document based on the comparison of the document to the static detection model; executing at least part of the document; determining whether attacking code is included in the document based on the execution of the at least part of the document; and if attacking code is determined to be included in the document based on at least one of the comparison of the document tomore » the static detection model and the execution of the at least part of the document, reporting the presence of an attack. In some embodiments, the methods include: selecting a data segment in at least one portion of an electronic document; determining whether the arbitrarily selected data segment can be altered without causing the electronic document to result in an error when processed by a corresponding program; in response to determining that the arbitrarily selected data segment can be altered, arbitrarily altering the data segment in the at least one portion of the electronic document to produce an altered electronic document; and determining whether the corresponding program produces an error state when the altered electronic document is processed by the corresponding program.« less
NASA Astrophysics Data System (ADS)
Colwell, F. S.; Ntarlagiannis, D.
2007-05-01
The new subdiscipline of biogeophysics has focused mostly on the geophysical signatures of microbial processes in contaminated subsurface environments usually undergoing remediation. However, the use of biogeophysics to examine the biogeochemistry of marine sediments has not yet been well-integrated into conceptual models that describe subseafloor processes. Current examples of geophysical measurements that have been used to detect geomicrobiological processes or infer their location in the seafloor include sound surveillance system (SOSUS)-derived data that detect seafloor eruptive events, deep and shallow cross-sectional seismic surveys that determine the presence of hydraulically conductive zones or gas-bearing sediments (e.g., bottom-simulating reflectors or bubble-rich strata), and thermal profiles. One possible area for innovative biogeophysical characterization of the seafloor involves determining the depth of the sulfate-methane interface (SMI) in locations where sulfate diffuses from the seawater and methane emanates from subsurface strata. The SMI demarcates a stratum where microbially-driven anaerobic methane oxidation (AMO) is dependent upon methane as an electron donor and sulfate as an electron acceptor. AMO is carried out by a recently defined, unique consortium of microbes that metabolically temper the flux of methane into the overlying seawater. The depth of the SMI is, respectively, shallow or deep according to whether a high or low rate of methane flux occurs from the deep sediments. Presently, the SMI can only be determined by direct measurements of methane and sulfate concentrations in the interstitial waters or by molecular biological techniques that target the microbes responsible for creating the SMI. Both methods require collection and considerable analysis of sediment samples. Therefore, detection of the SMI by non-destructive methods would be advantageous. As a key biogeochemical threshold in marine sediments, the depth of the SMI defines methane charge in marine sediments, whether it is from dissolved methane or from methane hydrates. As such, a biogeophysical strategy for determining SMI depth would represent an important contribution to assessing methane charge with respect to climate change, sediment stability, or potential energy resources.
Electronic Data Interchange: Selected Issues and Trends.
ERIC Educational Resources Information Center
Wigand, Rolf T.; And Others
1993-01-01
Describes electronic data interchange (EDI) as the application-to-application exchange of business documents in a computer-readable format. Topics discussed include EDI in various industries, EDI in finance and banking, organizational impacts of EDI, future EDI markets and organizations, and implications for information resources management.…
Crocodile Technology. [CD-ROM].
ERIC Educational Resources Information Center
2000
This high school physics computer software resource is a systems and control simulator that covers the topics of electricity, electronics, mechanics, and programming. Circuits can easily be simulated on the screen and electronic and mechanical components can be combined. In addition to those provided in Crocodile Technology, a student can create…
The Electronic Librarian: Inching Towards the Revolution
ERIC Educational Resources Information Center
Cuesta, Emerita M.
2005-01-01
Electronic resources are transforming the way librarians work. New technological skills have been added to the librarian's tool kit. Some libraries have undertaken large-scale organizational reconfigurations to meet the challenges of the digital environment. Yet libraries still rely on traditional functions such as acquisitions, cataloging, and…
The Archival View of Technology: Resources for the Scholar of the Future.
ERIC Educational Resources Information Center
Zeidberg, David S.
1999-01-01
Archivists need to apply traditional principles of records management to electronic documents if these records are to survive for research by future scholars. Additionally, archivists must ensure that the electronic records preserved remain accessible as hardware and software change over time. (Author/AEF)
Principled Libraries: Finding Stability in Changing Times.
ERIC Educational Resources Information Center
Crawford, Walt
2000-01-01
Discusses the transition that libraries are currently experiencing between physical resources and electronic access. Topics include technology as tools rather than solutions; media and technology; desktop publishing; electronic books; Web commerce; instant books, or books printed on demand; new types of media; and serving the users. (LRW)
Participative Knowledge Production of Learning Objects for E-Books.
ERIC Educational Resources Information Center
Dodero, Juan Manuel; Aedo, Ignacio; Diaz, Paloma
2002-01-01
Defines a learning object as any digital resource that can be reused to support learning and thus considers electronic books as learning objects. Highlights include knowledge management; participative knowledge production, i.e. authoring electronic books by a distributed group of authors; participative knowledge production architecture; and…
Agemura, Toshihide; Sekiguchi, Takashi
2018-02-01
Collection efficiency and acceptance maps of typical detectors in modern scanning electron microscopes (SEMs) were investigated. Secondary and backscattered electron trajectories from a specimen to through-the-lens and under-the-lens detectors placed on an electron optical axis and an Everhart-Thornley detector mounted on a specimen chamber were simulated three-dimensionally. The acceptance maps were drawn as the relationship between the energy and angle of collected electrons under different working distances. The collection efficiency considering the detector sensitivity was also estimated for the various working distances. These data indicated that the acceptance maps and collection efficiency are keys to understand the detection mechanism and image contrast for each detector in the modern SEMs. Furthermore, the working distance is the dominant parameter because electron trajectories are drastically changed with the working distance.
[Detection of toxic substances in microbial fuel cells].
Wang, Jiefu; Niu, Hao; Wu, Wenguo
2017-05-25
Microbial fuel cells (MFCs) is a highly promising bioelectrochemical technology and uses microorganisms as catalyst to convert chemical energy directly to electrical energy. Microorganisms in the anodic chamber of MFC oxidize the substrate and generate electrons. The electrons are absorbed by the anode and transported through an external circuit to the cathode for corresponding reduction. The flow of electrons is measured as current. This current is a linear measure of the activity of microorganisms. If a toxic event occurs, microbial activity will change, most likely decrease. Hence, fewer electrons are transported and current decreases as well. In this way, a microbial fuel cell-based biosensor provides a direct measure to detect toxicity for samples. This paper introduces the detection of antibiotics, heavy metals, organic pollutants and acid in MFCs. The existing problems and future application of MFCs are also analyzed.
Detecting magnetic ordering with atomic size electron probes
Idrobo, Juan Carlos; Rusz, Ján; Spiegelberg, Jakob; ...
2016-05-27
While magnetism originates at the atomic scale, the existing spectroscopic techniques sensitive to magnetic signals only produce spectra with spatial resolution on a larger scale. However, recently, it has been theoretically argued that atomic size electron probes with customized phase distributions can detect magnetic circular dichroism. Here, we report a direct experimental real-space detection of magnetic circular dichroism in aberration-corrected scanning transmission electron microscopy (STEM). Using an atomic size-aberrated electron probe with a customized phase distribution, we reveal the checkerboard antiferromagnetic ordering of Mn moments in LaMnAsO by observing a dichroic signal in the Mn L-edge. The novel experimental setupmore » presented here, which can easily be implemented in aberration-corrected STEM, opens new paths for probing dichroic signals in materials with unprecedented spatial resolution.« less
Piezoelectric-based self-powered electronic adjustable impulse switches
NASA Astrophysics Data System (ADS)
Rastegar, Jahangir; Kwok, Philip
2018-03-01
Novel piezoelectric-based self-powered impulse detecting switches are presented. The switches are designed to detect shock loading events resulting in acceleration or deceleration above prescribed levels and durations. The prescribed acceleration level and duration thresholds are adjustable. They are provided with false trigger protection logic. The impulse switches are provided with electronic and logic circuitry to detect prescribed impulse events and reject events such as high amplitude but short duration shocks, and transportation vibration and similar low amplitude and relatively long duration events. They can be mounted directly onto electronics circuit boards, thereby significantly simplifying the electrical and electronic circuitry, simplifying the assembly process and total cost, significantly reducing the occupied volume, and in some applications eliminating the need for physical wiring to and from the impulse switches. The design of prototypes and testing under realistic conditions are presented.
Modeling and validating HL7 FHIR profiles using semantic web Shape Expressions (ShEx).
Solbrig, Harold R; Prud'hommeaux, Eric; Grieve, Grahame; McKenzie, Lloyd; Mandel, Joshua C; Sharma, Deepak K; Jiang, Guoqian
2017-03-01
HL7 Fast Healthcare Interoperability Resources (FHIR) is an emerging open standard for the exchange of electronic healthcare information. FHIR resources are defined in a specialized modeling language. FHIR instances can currently be represented in either XML or JSON. The FHIR and Semantic Web communities are developing a third FHIR instance representation format in Resource Description Framework (RDF). Shape Expressions (ShEx), a formal RDF data constraint language, is a candidate for describing and validating the FHIR RDF representation. Create a FHIR to ShEx model transformation and assess its ability to describe and validate FHIR RDF data. We created the methods and tools that generate the ShEx schemas modeling the FHIR to RDF specification being developed by HL7 ITS/W3C RDF Task Force, and evaluated the applicability of ShEx in the description and validation of FHIR to RDF transformations. The ShEx models contributed significantly to workgroup consensus. Algorithmic transformations from the FHIR model to ShEx schemas and FHIR example data to RDF transformations were incorporated into the FHIR build process. ShEx schemas representing 109 FHIR resources were used to validate 511 FHIR RDF data examples from the Standards for Trial Use (STU 3) Ballot version. We were able to uncover unresolved issues in the FHIR to RDF specification and detect 10 types of errors and root causes in the actual implementation. The FHIR ShEx representations have been included in the official FHIR web pages for the STU 3 Ballot version since September 2016. ShEx can be used to define and validate the syntax of a FHIR resource, which is complementary to the use of RDF Schema (RDFS) and Web Ontology Language (OWL) for semantic validation. ShEx proved useful for describing a standard model of FHIR RDF data. The combination of a formal model and a succinct format enabled comprehensive review and automated validation. Copyright © 2017 Elsevier Inc. All rights reserved.
Detecting single-electron events in TEM using low-cost electronics and a silicon strip sensor.
Gontard, Lionel C; Moldovan, Grigore; Carmona-Galán, Ricardo; Lin, Chao; Kirkland, Angus I
2014-04-01
There is great interest in developing novel position-sensitive direct detectors for transmission electron microscopy (TEM) that do not rely in the conversion of electrons into photons. Direct imaging improves contrast and efficiency and allows the operation of the microscope at lower energies and at lower doses without loss in resolution, which is especially important for studying soft materials and biological samples. We investigate the feasibility of employing a silicon strip detector as an imaging detector for TEM. This device, routinely used in high-energy particle physics, can detect small variations in electric current associated with the impact of a single charged particle. The main advantages of using this type of sensor for direct imaging in TEM are its intrinsic radiation hardness and large detection area. Here, we detail design, simulation, fabrication and tests in a TEM of the front-end electronics developed using low-cost discrete components and discuss the limitations and applications of this technology for TEM.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Trainham, Clifford P.; O'Neill, Mary D.; McKenna, Ian J.
The rate equations found in frequency domain fluorescence spectroscopy are the same as those found in electronics under analog filter theory. Laplace transform methods are a natural way to solve the equations, and the methods can provide solutions for arbitrary excitation functions. The fluorescence terms can be modeled as circuit components and cascaded with drive and detection electronics to produce a global transfer function. Electronics design tools such as Spicea can be used to model fluorescence problems. In applications, such as remote sensing, where detection electronics are operated at high gain and limited bandwidth, a global modeling of the entiremore » system is important, since the filter terms of the drive and detection electronics affect the measured response of the fluorescence signals. Furthermore, the techniques described here can be used to separate signals from fast and slow fluorophores emitting into the same spectral band, and data collection can be greatly accelerated by means of a frequency comb driver waveform and appropriate signal processing of the response.« less
An analog filter approach to frequency domain fluorescence spectroscopy
Trainham, Clifford P.; O'Neill, Mary D.; McKenna, Ian J.
2015-10-01
The rate equations found in frequency domain fluorescence spectroscopy are the same as those found in electronics under analog filter theory. Laplace transform methods are a natural way to solve the equations, and the methods can provide solutions for arbitrary excitation functions. The fluorescence terms can be modeled as circuit components and cascaded with drive and detection electronics to produce a global transfer function. Electronics design tools such as Spicea can be used to model fluorescence problems. In applications, such as remote sensing, where detection electronics are operated at high gain and limited bandwidth, a global modeling of the entiremore » system is important, since the filter terms of the drive and detection electronics affect the measured response of the fluorescence signals. Furthermore, the techniques described here can be used to separate signals from fast and slow fluorophores emitting into the same spectral band, and data collection can be greatly accelerated by means of a frequency comb driver waveform and appropriate signal processing of the response.« less
Electron-rich triphenylamine-based sensors for picric acid detection.
Chowdhury, Aniket; Mukherjee, Partha Sarathi
2015-04-17
This paper demonstrates the role of solvent in selectivity and sensitivity of a series of electron-rich compounds for the detection of trace amounts of picric acid. Two new electron-rich fluorescent esters (6, 7) containing a triphenylamine backbone as well as their analogous carboxylic acids (8, 9) have been synthesized and characterized. Fluorescent triphenylamine coupled with an ethynyl moiety constitutes π-electron-rich selective and sensitive probes for electron-deficient picric acid (PA). In solution, the high sensitivity of all the sensors toward PA can be attributed to a combined effect of the ground-state charge-transfer complex formation and resonance energy transfer between the sensor and analyte. The acids 8 and 9 also showed enhanced sensitivity for nitroaromatics in the solid state, and their enhanced sensitivity could be attributed to exciton migration due to close proximity of the neighboring acid molecules, as evident from the X-ray diffraction study. The compounds were found to be quite sensitive for the detection of trace amount of nitroaromatics in solution, solid, and contact mode.
Self-exchange reactions of radical anions in n-hexane.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Werst, D. W.; Chemistry
The formation and reactions of radical anions in n-hexane at 190 K were investigated by pulse radiolysis and time-resolved fluorescence-detected magnetic resonance (FDMR). Electron attachment was found to occur for compounds with gas-phase electron affinities (EA) more positive than -1.1 {+-} 0.1 eV. The FDMR concentration and time dependence are interpreted as evidence for self-exchange electron-transfer reactions, indicating that formation of dimer radical anions is not prevalent for the range of molecules studied. FDMR detection of radical anions is mainly restricted to electron acceptors with EA less than approximately 0.5 eV.
Burkart, M.R.; Kolpin, D.W.
1993-01-01
The US Geological Survey, US Department of Agriculture, and US Environmental Protection Agency are conducting research and regional assessments in support of policy alternatives intended to protect water resources from agricultural chemical contamination. The mid-continent was selected because of the intense row crop agriculture and associated herbicide application in this region. An application of a geographic information system is demonstrated for analyzing and comparing the distribution of estimated atrazine use to the detection rate of atrazine in groundwater. Understanding the relations between atrazine use and detection in groundwater is important in policy deliberations to protect water resources. Relational analyses between measures of chemical use and detection rate by natural resource units may provide insight into critical factors controlling the processes that result in groundwater contamination from agricultural chemicals.
2004-11-16
MATLAB Algorithms for Rapid Detection and Embedding of Palindrome and Emordnilap Electronic Watermarks in Simulated Chemical and Biological Image ...and Emordnilap Electronic Watermarks in Simulated Chemical and Biological Image Data 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT...Conference on Chemical and Biological Defense Research. Held in Hunt Valley, Maryland on 15-17 November 2004., The original document contains color images
Costs of measuring leaf area index of corn
NASA Technical Reports Server (NTRS)
Daughtry, C. S. T.; Hollinger, S. E.
1984-01-01
The magnitude of plant-to-plant variability of leaf area of corn plants selected from uniform plots was examined and four representative methods for measuring leaf area index (LAI) were evaluated. The number of plants required and the relative costs for each sampling method were calculated to detect 10, 20, and 50% differences in LAI using 0.05 and 0.01 tests of significance and a 90% probability of success (beta = 0.1). The natural variability of leaf area per corn plant was nearly 10%. Additional variability or experimental error may be introduced by the measurement technique employed and by nonuniformity within the plot. Direct measurement of leaf area with an electronic area meter had the lowest CV, required that the fewest plants be sampled, but required approximately the same amount of time as the leaf area/weight ratio method to detect comparable differences. Indirect methods based on measurements of length and width of leaves required more plants but less total time than the direct method. Unless the coefficients for converting length and width to area are verified frequently, the indirect methods may be biased. When true differences in LAI among treatments exceed 50% of mean, all four methods are equal. The method of choice depends on the resources available, the differences to be detected, and what additional information, such as leaf weight or stalk weight, is also desired.
ACT-R Electronic Bookshelf: An Adaptive System To Support Learning ACT-R on the Web.
ERIC Educational Resources Information Center
Brusilovsky, Peter; Anderson, John
This paper describes the electronic ACT-R Bookshelf, a system which supports learning ACT-R, a well-known theory in the field of cognitive psychology, over the World Wide Web. ACT-R Bookshelf is a collection of electronic books on various aspects of ACT-R. The primary role of ACT-R Bookshelf is to serve as a 24-hour information resource for…
ERIC Educational Resources Information Center
Hodkinson, Alan
2012-01-01
This paper examines the picture of disability portrayed within the electronic media presented to primary-aged pupils in England. The study employed proto-text analysis to examine 494 separate electronic resources which contained 4485 illustrations, 930 photographs and 59 video clips. The major finding of the research is that the media examined…
Martone, Maryann E.; Tran, Joshua; Wong, Willy W.; Sargis, Joy; Fong, Lisa; Larson, Stephen; Lamont, Stephan P.; Gupta, Amarnath; Ellisman, Mark H.
2008-01-01
Databases have become integral parts of data management, dissemination and mining in biology. At the Second Annual Conference on Electron Tomography, held in Amsterdam in 2001, we proposed that electron tomography data should be shared in a manner analogous to structural data at the protein and sequence scales. At that time, we outlined our progress in creating a database to bring together cell level imaging data across scales, The Cell Centered Database (CCDB). The CCDB was formally launched in 2002 as an on-line repository of high-resolution 3D light and electron microscopic reconstructions of cells and subcellular structures. It contains 2D, 3D and 4D structural and protein distribution information from confocal, multiphoton and electron microscopy, including correlated light and electron microscopy. Many of the data sets are derived from electron tomography of cells and tissues. In the five years since its debut, we have moved the CCDB from a prototype to a stable resource and expanded the scope of the project to include data management and knowledge engineering. Here we provide an update on the CCDB and how it is used by the scientific community. We also describe our work in developing additional knowledge tools, e.g., ontologies, for annotation and query of electron microscopic data. PMID:18054501
Stewart, S C; Rapnicki, P; Lewis, J R; Perala, M
2007-09-01
The ability of a commercially available panel reader system to read International Standards Organization-compliant electronic identification devices under commercial dairy conditions was examined. Full duplex (FDX-B) and half-duplex (HDX) low frequency radio-frequency identification external ear tags were utilized. The study involved 498 Holstein cows in the final 6 wk of gestation. There were 516 total electronic identification devices (n = 334 HDX and n = 182 FDX-B). Eighteen FDX-B were replaced with HDX during the study due to repeated detection failure. There were 6,679 HDX and 3,401 FDX-B device detection attempts. There were 220 (2.2%) unsuccessful and 9,860 (97.8%) successful identification detection attempts. There were 9 unsuccessful detection attempts for HDX (6,670/6,679 = 99.9% successful detection attempts) and 211 unsuccessful detection attempts for FDX-B (3,190/3,401 = 93.8% successful detection attempts). These results demonstrate that this panel system can achieve high detection rates of HDX devices and meet the needs of the most demanding management applications. The FDX-B detection rate was not sufficient for the most demanding applications, requiring a high degree of detection by panel readers. The lower FDX-B rate may not be inherent in the device technology itself, but could be due to other factors, including the particular panel reader utilized or the tuning of the panel reader.
The Internet and World-Wide-Web: Potential Benefits to Rural Schools.
ERIC Educational Resources Information Center
Barker, Bruce O.
The Internet is a decentralized collection of computer networks managed by separate groups using a common set of technical standards. The Internet has tremendous potential as an educational resource by providing access to networking through worldwide electronic mail, various databases, and electronic bulletin boards; collaborative investigation…
Occupational Education for Students with Special Needs: Electronic Assembly.
ERIC Educational Resources Information Center
Nassau County Board of Cooperative Educational Services, Westbury, NY.
This curriculum resource guide on electronic assembly is one of a series of seventeen specialized curriculum guides for occupational education of the marginal, handicapped, or special needs occupational education student. The guide begins with six behavior clusters that contain a series of forty-two instructional topics designed to teach…
Power Electronics and Electric Machines | Transportation Research | NREL
-to resource for information from cutting-edge thermal management research, making wide-scale adoption battery, the motor, and other powertrain components. NREL's thermal management and reliability research is thermal management technologies to improve performance, cost, and reliability for power electronics and
Federal Register 2010, 2011, 2012, 2013, 2014
2013-02-20
... Gathering Meetings for the Electronic Manifest (e-Manifest) System AGENCY: Environmental Protection Agency (EPA). ACTION: Notice of public meetings. SUMMARY: EPA's Office of Resource Conservation and Recovery...'') system to capture information regarding the shipment of hazardous waste from the time it leaves the...
Electronic Literacy, Critical Pedagogy, and Collaboration: A Case for Cyborg Writing.
ERIC Educational Resources Information Center
Winkelmann, Carol L.
1995-01-01
Argues that the combination of collaborative writing and electronic resources can produce a reaffirmation of literacy as a social process. Utilizes feminist theory to equate the postmodernist assumptions regarding the indeterminate nature of language with democratizing influences. Describes a class project where students produced a collaborative,…
Complex Moving Parts: Assessment Systems and Electronic Portfolios
ERIC Educational Resources Information Center
Larkin, Martha J.; Robertson, Royce L.
2013-01-01
The largest college within an online university of over 50,000 students invested significant resources in translating a complex assessment system focused on continuous improvement and national accreditation into an effective and efficient electronic portfolio (ePortfolio). The team building the system needed a model to address problems met…
Electronic Resources and the Education of History Professionals
ERIC Educational Resources Information Center
Mulligan, William H., Jr.
2001-01-01
The transforming effects of the tremendous advances in technology that have reshaped the economy and many other elements of American society have had an equally profound impact on historical agencies. The personal computer, the Internet, and associated electronic communications developments have already transformed the museum and historical agency…
NASA Tech Briefs, December 1998. Volume 22, No. 12
NASA Technical Reports Server (NTRS)
1998-01-01
Topics include: special coverage section on design and analysis software, and sections on electronic components and circuits, electronic systems, software, materials, mechanics, machinery/automation, manufacturing/fabrication, physical sciences, and special sections of Photonics Tech Briefs, Motion Control Tech briefs and a Hot Technology File 1999 Resource Guide.
The Electronic Portfolio Boom: What's It All About?
ERIC Educational Resources Information Center
Batson, Trent
2002-01-01
Discusses the use of electronic portfolios in higher education. Highlights include availability of the Web and databases; the growth of vendors in this area; benefits to students, faculty, and administrators, including statistics for accreditation; data storage; data security; certification issues; and a list of ePortfolio tools and resources.…
Shang, Kuo-Chung; Lu, Chin-Shan; Li, Shaorui
2010-05-01
This study investigated crucial green supply chain management (GSCM) capability dimensions and firm performance based on electronics-related manufacturing firms in Taiwan. On the basis of a factor analysis, six green supply chain management dimensions were identified: green manufacturing and packaging, environmental participation, green marketing, green suppliers, green stock, and green eco-design. According to their factor scores in the GSCM dimensions, a cluster analysis subsequently assigned responding firms into four groups, namely, the weak GSCM oriented group, the green marketing oriented group, the green supplier oriented group, and the green stock oriented group. Differences in firm performance and GSCM dimensions among groups were examined. Results indicated that the green marketing oriented group performed best. Based on the resource-based view (RBV), the capability of the green marketing oriented group was considered to be the deployment of a collection of resources that enables it to successfully compete against rivals. The importance of green marketing as a GSCM capability and strategic asset/critical resources for electronics-related manufacturing firms to obtain a competitive edge is therefore highlighted in this study. Copyright 2010 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Fisher, Mark; Sikes, John; Prather, Mark
2004-09-01
The dog's nose is an effective, highly-mobile sampling system, while the canine olfactory organs are an extremely sensitive detector. Having been trained to detect a wide variety of substances with exceptional results, canines are widely regarded as the 'gold standard' in chemical vapor detection. Historically, attempts to mimic the ability of dogs to detect vapors of explosives using electronic 'dogs noses' has proven difficult. However, recent advances in technology have resulted in development of detection (i.e., sampling and sensor) systems with performance that is rapidly approaching that of trained canines. The Nomadics Fido was the first sensor to demonstrate under field conditions the detection of landmines with performance approaching that of canines. More recently, comparative testing of Fido against canines has revealed that electronic vapor detection, when coupled with effective sampling methods, can produce results comparable to that of highly-trained canines. The results of these comparative tests will be presented, as will recent test results in which explosives hidden in cargo were detected using Fido with a high-volume sampling technique. Finally, the use of canines along with electronic sensors will be discussed as a means of improving the performance and expanding the capabilities of both methods.
Biomolecule detection based on Si single-electron transistors for practical use
NASA Astrophysics Data System (ADS)
Nakajima, Anri; Kudo, Takashi; Furuse, Sadaharu
2013-07-01
Experimental and theoretical analyses demonstrated that ultra-sensitive biomolecule detection can be achieved using a Si single-electron transistor (SET). A multi-island channel structure was used to enable room-temperature operation. Coulomb oscillation increases transconductance without increasing channel width, which increases detection sensitivity to a charged target. A biotin-modified SET biosensor was used to detect streptavidin at a dilute concentration. In addition, an antibody-functionalized SET biosensor was used for immunodetection of prostate-specific antigen, demonstrating its suitability for practical use. The feasibility of ultra-sensitive detection of biomolecules for practical use by using a SET biosensor was clearly proven through this systematic study.
NASA Technical Reports Server (NTRS)
Balasubrahmanyan, V. K.; Stephens, S. A.
1983-01-01
Synchrotron emission by a high-energy electron in the geomagnetic field and its dependence upon different arrival directions over Palestine, Texas, where major balloon-borne experiments are being conducted, is studied. The dependence of detector response on the arrival direction of electron, the different criteria which are adopted to identify an electron event, the area of the detector, and the energy of the electron are discussed. An omnidirectional circular detector is used to examine whether it is possible to determine the energy of an electron without knowing its arrival direction. The collecting power of a detector is estimated as a function of the energy of electrons for different detector areas with different selection criteria, and this information is used to calculate the event rates expected by folding in the energy spectrum of cosmic ray electrons to show the viability of detecting cosmic ray electrons at energies greater than a few TeV.
NASA Astrophysics Data System (ADS)
Tang, C. L.; Zhang, J.; Reeves, G. D.; Baker, D. N.; Spence, H. E.; Funsten, H. O.; Blake, J. B.
2015-12-01
We present multipoint observations (RBSP, GEOS and THEMIS) of the substorm electron injections during the substorm event on 16 August 2013. RBSP-A detected the MeV electron phase space density increased by an order of magnitude in about one hour at L* > 5.0. At L* = 4.4, the injected MeV electrons were also detected. It is suggested that the magnetic field dipolarization associated with the substorm injections alone can explain that the prompt recovery and enhancements of the relativistic electron (~ MeV) fluxes in the outer radiation belt. The observations of THEMIS-A also first presented that the near-Earth magnetotail at substorm onset is important in the MeV electron injection event: the enhanced fluxes of ~200 keV electrons are the source population and intense electromagnetic pulses are the driving source of MeV injected electrons. The pulse model is used to explain the dispersionless MeV injected electrons in the outer radiation belt observed by GEOS-13 and RBSP-A.
Talundzic, Eldin; Maganga, Mussa; Masanja, Irene M; Peterson, David S; Udhayakumar, Venkatachalam; Lucchi, Naomi W
2014-01-27
Accurate diagnosis of malaria infections remains challenging, especially in the identification of submicroscopic infections. New molecular diagnostic tools that are inexpensive, sensitive enough to detect low-level infections and suitable in laboratory settings of resource-limited countries are required for malaria control and elimination programmes. Here the diagnostic potential of a recently developed photo-induced electron transfer fluorogenic primer (PET) real-time polymerase chain reaction (PCR) called PET-PCR was investigated. This study aimed to (i) evaluate the use of this assay as a method for the detection of both Plasmodium falciparum and other Plasmodium species infections in a developing country's diagnostic laboratory; and, (ii) determine the assay's sensitivity and specificity compared to a nested 18S rRNA PCR. Samples used in this study were obtained from a previous study conducted in the region of Iringa, Tanzania. A total of 303 samples from eight health facilities in Tanzania were utilized for this evaluation. All samples were screened using the multiplex PET-PCR assay designed to detect Plasmodium genus and P. falciparum initially in laboratory in Tanzania and then repeated at a reference laboratory at the CDC in the USA. Microscopy data was available for all the 303 samples. A subset of the samples were tested in a blinded fashion to find the sensitivity and specificity of the PET-PCR compared to the nested 18S rRNA PCR. Compared to microscopy, the PET-PCR assay was 59% more sensitive in detecting P. falciparum infections. The observed sensitivity and specificity were 100% (95% confidence interval (CI0.95) = 94-100%) and (CI0.95 = 96-100%), respectively, for the PET-PCR assay when compared to nested 18S rRNA PCR. When compared to 18S rRNA PCR, microscopy had a low sensitivity of 40% (CI0.95 = 23-61%) and specificity of 100% (CI0.95 = 96-100%). The PET-PCR results performed in the field laboratory in Tanzania were in 100% concordance with the results obtained at the reference laboratory in the USA. The PET-PCR is a new molecular diagnostic tool with similar performance characteristics as commonly used PCR methods that is less expensive, easy to use, and amiable to large scale-surveillance studies in developing country settings.
Electronics Environmental Benefits Calculator
The Electronics Environmental Benefits Calculator (EEBC) was developed to assist organizations in estimating the environmental benefits of greening their purchase, use and disposal of electronics.The EEBC estimates the environmental and economic benefits of: Purchasing Electronic Product Environmental Assessment Tool (EPEAT)-registered products; Enabling power management features on computers and monitors above default percentages; Extending the life of equipment beyond baseline values; Reusing computers, monitors and cell phones; and Recycling computers, monitors, cell phones and loads of mixed electronic products.The EEBC may be downloaded as a Microsoft Excel spreadsheet.See https://www.federalelectronicschallenge.net/resources/bencalc.htm for more details.
Rising Expectations: Access to Biomedical Information
Lindberg, D. A. B.; Humphreys, B. L.
2008-01-01
Summary Objective To provide an overview of the expansion in public access to electronic biomedical information over the past two decades, with an emphasis on developments to which the U.S. National Library of Medicine contributed. Methods Review of the increasingly broad spectrum of web-accessible genomic data, biomedical literature, consumer health information, clinical trials data, and images. Results The amount of publicly available electronic biomedical information has increased dramatically over the past twenty years. Rising expectations regarding access to biomedical information were stimulated by the spread of the Internet, the World Wide Web, advanced searching and linking techniques. These informatics advances simplified and improved access to electronic information and reduced costs, which enabled inter-organizational collaborations to build and maintain large international information resources and also aided outreach and education efforts The demonstrated benefits of free access to electronic biomedical information encouraged the development of public policies that further increase the amount of information available. Conclusions Continuing rapid growth of publicly accessible electronic biomedical information presents tremendous opportunities and challenges, including the need to ensure uninterrupted access during disasters or emergencies and to manage digital resources so they remain available for future generations. PMID:18587496
Information-seeking behavior of health sciences faculty: the impact of new information technologies.
Curtis, K L; Weller, A C; Hurd, J M
1997-10-01
This paper reports on an ongoing investigation into health sciences faculty's information-seeking behavior, including their use of new information technologies. A survey was administered to all faculty in medicine, nursing, and pharmacy at the University of Illinois at Chicago. It was similar to one administered to the same population in 1991. The survey asked about faculty's use of electronic resources, documented any shift from the use of print to electronic formats, and measured the utilization of library training. The response rate was 48.5% for medicine faculty, 45.0% for nursing, and 62.5% for pharmacy. The study found that use of the print Index Medicus among faculty was in transition: While 30.5% continued to use the print resources, 68.0% of faculty accessed MEDLINE through electronic means. Faculty preferred accessing electronic databases from their offices to doing so from the library. Health sciences faculty used a wide variety of databases, in addition to MEDLINE, to fill their information needs. Most faculty did not take advantage of either in-house or electronic training sessions offered by librarians. The study concluded that the training preferences of faculty need to be further explored.
Sustainable Materials Management Challenge Data
Sustainable Materials Management (SMM) is a systemic approach to using and reusing materials more productively over their entire lifecycles. It represents a change in how our society thinks about the use of natural resources and environmental protection. By looking at a product's entire lifecycle we can find new opportunities to reduce environmental impacts, conserve resources, and reduce costs. There are multiple challenge programs available as part of the SMM program, including the Food Recovery Challenge, the Electronics Challenge, the Federal Green Challenge, and the WasteWise program. As part of EPA's Food Recovery Challenge, organizations pledge to improve their sustainable food management practices and report their results. The SMM Electronics Challenge encourages electronics manufacturers, brand owners and retailers to strive to send 100 percent of the used electronics they collect from the public, businesses and within their own organizations to third-party certified electronics refurbishers and recyclers. The Federal Green Challenge, a national effort under the EPA??s Sustainable Materials Management Program, challenges EPA and other federal agencies throughout the country to lead by example in reducing the federal government's environmental impact. EPA??s WasteWise encourages organizations and businesses to achieve sustainability in their practices and reduce select industrial wastes. WasteWise is part of EPA??s sustaina
Adler, D; Mahler, Y
1980-04-01
A procedure for automatic detection and digital processing of the maximum first derivative of the intraventricular pressure (dp/dtmax), time to dp/dtmax(t - dp/dt) and beat-to-beat intervals have been developed. The procedure integrates simple electronic circuits with a short program using a simple algorithm for the detection of the points of interest. The tasks of differentiating the pressure signal and detecting the onset of contraction were done by electronics, while the tasks of finding the values of dp/dtmax, t - dp/dt, beat-to-beat intervals and all computations needed were done by software. Software/hardware 'trade off' considerations and the accuracy and reliability of the system are discussed.
Induction-detection electron spin resonance with spin sensitivity of a few tens of spins
DOE Office of Scientific and Technical Information (OSTI.GOV)
Artzi, Yaron; Twig, Ygal; Blank, Aharon
2015-02-23
Electron spin resonance (ESR) is a spectroscopic method that addresses electrons in paramagnetic materials directly through their spin properties. ESR has many applications, ranging from semiconductor characterization to structural biology and even quantum computing. Although it is very powerful and informative, ESR traditionally suffers from low sensitivity, requiring many millions of spins to get a measureable signal with commercial systems using the Faraday induction-detection principle. In view of this disadvantage, significant efforts were made recently to develop alternative detection schemes based, for example, on force, optical, or electrical detection of spins, all of which can reach single electron spin sensitivity.more » This sensitivity, however, comes at the price of limited applicability and usefulness with regard to real scientific and technological issues facing modern ESR which are currently dealt with conventional induction-detection ESR on a daily basis. Here, we present the most sensitive experimental induction-detection ESR setup and results ever recorded that can detect the signal from just a few tens of spins. They were achieved thanks to the development of an ultra-miniature micrometer-sized microwave resonator that was operated at ∼34 GHz at cryogenic temperatures in conjunction with a unique cryogenically cooled low noise amplifier. The test sample used was isotopically enriched phosphorus-doped silicon, which is of significant relevance to spin-based quantum computing. The sensitivity was experimentally verified with the aid of a unique high-resolution ESR imaging approach. These results represent a paradigm shift with respect to the capabilities and possible applications of induction-detection-based ESR spectroscopy and imaging.« less
Use of electronic noses for detection of odour from animal production facilities: a review.
Nimmermark, S
2001-01-01
In the field of controlling livestock and poultry odours in the internal and external environment and in derived food products, one main obstacle is how to measure the odour in a suitable way. Olfactometry and a human panel have been used in most studies of farm odour until now. Alternatives like electronic noses are interesting considering disadvantages for olfactometry regarding cost and labour requirement. An electronic device can produce an almost instant response which is useful in many applications. Studies have shown detection of farm odour for some electronic noses and also response to odour concentrations. Other studies have shown very high odour threshold values compared to human noses. Electronic noses with a large number of sensors have been developed since a base was formed in the 1950s. The fast progress in data processing and sensor development in the latest years have made the electronic noses interesting for a large number of industrial applications in the food processing industry, as well as in other areas. Materials like manure produce a complex mixture of odorous compounds and the interaction between these creates a unique odour where no specific dominating and characterising compound seems to exist. Related to swine farms almost 200 different odorous compounds have been reported. The electronic noses can, depending on the sensitivity of its sensors, detect some compounds at lower levels than the human nose, while other compounds offensive to a human nose cannot be detected. Proper function of the electronic noses with sensitivity for the odorous gases in the application must be followed by satisfying properties regarding ageing, temperature stability, humidity and other environmental factors.
ERMes: Open Source Simplicity for Your E-Resource Management
ERIC Educational Resources Information Center
Doering, William; Chilton, Galadriel
2009-01-01
ERMes, the latest version of electronic resource management system (ERM), is a relational database; content in different tables connects to, and works with, content in other tables. ERMes requires Access 2007 (Windows) or Access 2008 (Mac) to operate as the database utilizes functionality not available in previous versions of Microsoft Access. The…
New York State Forum for Information Resource Management: 1998-1999 Annual Report.
ERIC Educational Resources Information Center
New York State Forum for Information Resource Management.
This annual report of the New York State Forum for Information Resource Management begins with a section that summarizes key activities for 1998-99, including partnerships with other organizations, sessions on the use of information in government and information security, programs on the challenges of electronic commerce for government,…
Schools and Districts Use Resources Wisely to Increase Achievement and Graduate More Students.
ERIC Educational Resources Information Center
Southern Regional Education Board (SREB), 2011
2011-01-01
In a time of reduced funding, schools are meeting the challenge to continue improving classroom practices, student achievement and graduation rates. Many schools and teachers are forming networks to exchange information via the Internet as they tap into free electronic resources. Career/technical (CT) instructors are teaching students about…
Integrating courses with the Internet: Preparing the Teacher As Well As the Learner.
ERIC Educational Resources Information Center
Williams, Arthur E.
Most colleges and universities have Internet connections that provide students and faculty access to a world of information resources. The challenge for instructors and the administrators is integrating these resources into the curriculum. One of the most influential technologies is electronic mail, which helps foster communication between…
A Selection of Gilded-Age Resources on the World Wide Web.
ERIC Educational Resources Information Center
Lewis, Alison
1999-01-01
Provides a collection of websites on the Gilded Age that include lesson plans, a chronology, electronic texts, and other resources. Offers a variety of topics such as, but not limited to, African American history, coal mining, political cartoons, architecture, bibliographical information on public figures, and the Spanish-American War. (CMK)
Developing Student Gifts and Talents Using Web-Based Resources
ERIC Educational Resources Information Center
Code, Kimberly P.
2007-01-01
Technology is an essential part of young people's lives. Students today are digital natives who cannot remember a time without electronic media and technologies. Children who use the Internet spend 37 percent less time watching television and 16 percent more time with friends and family. The Internet is an excellent resource for differentiating…
How the OCLC CORC Service Is Helping Weave Libraries into the Web.
ERIC Educational Resources Information Center
Covert, Kay
2001-01-01
Describes OCLC's CORC (Cooperative Online Resource Catalog) service. As a state-of-the-art Web-based metadata creation system, CORC is optimized for creating bibliographic records and pathfinders for electronic resources. Discusses how libraries are using CORC in technical services, public services, and collection development and explains the…
MendelWeb: An Electronic Science/Math/History Resource for the WWW.
ERIC Educational Resources Information Center
Blumberg, Roger B.
This paper describes a hypermedia resource, called MendelWeb that integrates elementary biology, discrete mathematics, and the history of science. MendelWeb is constructed from Gregor Menders 1865 paper, "Experiments in Plant Hybridization". An English translation of Mendel's paper, which is considered to mark the birth of classical and…
ERIC Educational Resources Information Center
Alem, Leila; McLean, Alistair
2005-01-01
Community participation is central to achieving sustainable natural resource management. A prerequisite to informed participation is that community and stakeholder groups have access to different knowledge sources, are more closely attuned to the different issues and viewpoints, and are sufficiently equipped to understand and maybe resolve complex…
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-04
... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. RM10-11-000] Integration of Variable Energy Resources; Notice Of Filing Procedures for Order No. 764 Electronic Compliance Filings Take notice of the following filing procedures with respect to compliance obligations in Integration of...
Helping Patrons Find Locally Held Electronic Resources: An Interlibrary Loan Perspective
ERIC Educational Resources Information Center
Johnston, Pamela
2016-01-01
The University of North Texas Libraries provide extensive online access to academic journals through major vendor databases. As illustrated by interlibrary loan borrowing requests for items held in our databases, patrons often have difficulty navigating the available resources. In this study, the Interlibrary Loan staff used data gathered from the…
Research Capacity Building in Education: The Role of Digital Archives
ERIC Educational Resources Information Center
Carmichael, Patrick
2011-01-01
Accounts of how research capacity in education can be developed often make reference to electronic networks and online resources. This paper presents a theoretically driven analysis of the role of one such resource, an online archive of educational research studies that includes not only digitised collections of original documents but also videos…
23 CFR 450.214 - Development and content of the long-range statewide transportation plan.
Code of Federal Regulations, 2013 CFR
2013-04-01
..., Tribal, and local agencies responsible for land use management, natural resources, environmental... transportation plans to inventories of natural or historic resources, if available. (j) A long-range statewide...) in electronically accessible formats and means, such as the World Wide Web, as described in § 450.210...
23 CFR 450.214 - Development and content of the long-range statewide transportation plan.
Code of Federal Regulations, 2012 CFR
2012-04-01
..., Tribal, and local agencies responsible for land use management, natural resources, environmental... transportation plans to inventories of natural or historic resources, if available. (j) A long-range statewide...) in electronically accessible formats and means, such as the World Wide Web, as described in § 450.210...
23 CFR 450.214 - Development and content of the long-range statewide transportation plan.
Code of Federal Regulations, 2014 CFR
2014-04-01
..., Tribal, and local agencies responsible for land use management, natural resources, environmental... transportation plans to inventories of natural or historic resources, if available. (j) A long-range statewide...) in electronically accessible formats and means, such as the World Wide Web, as described in § 450.210...
Using Personal Computers To Acquire Special Education Information. Revised. ERIC Digest #429.
ERIC Educational Resources Information Center
ERIC Clearinghouse on Handicapped and Gifted Children, Reston, VA.
This digest offers basic information about resources, available to users of personal computers, in the area of professional development in special education. Two types of resources are described: those that can be purchased on computer diskettes and those made available by linking personal computers through electronic telephone networks. Resources…
77 FR 54877 - Deschutes and Ochoco National Forests Resource Advisory Committee
Federal Register 2010, 2011, 2012, 2013, 2014
2012-09-06
... National Forests Resource Advisory Committee will meet in Bend, Oregon. The purpose of the meeting is to... Hawthorne Avenue, Bend, OR 97701. Send written comments to John Allen as Designated Federal Official, for..., Deschutes National Forest, 63095 Deschutes Market Road., Bend, OR 97701 or electronically to [email protected
Council on Library Resources, Inc., 39th Annual Report, 1995.
ERIC Educational Resources Information Center
Council on Library Resources, Inc., Washington, DC.
This report emphasizes the plan of the new President of the Council on Library Resources (CLR) plan to concentrate on the development of leadership in libraries to better manage technologically advanced services, the transition to the electronic library, and the economics of information and information technology. The Council engaged in a project…
Pallen, M
1995-11-25
The benefits to medical practitioners of using the Internet are growing rapidly as the Internet becomes easier to use and ever more biomedical resources become available on line. The Internet is the largest computer network in the world; it is also a virtual community, larger than many nation states, with its own rules of behaviour or "netiquette." There are several types of Internet connection and various ways of acquiring a connection. Once connected, you can obtain, free of charge, programs that allow easy use of the Internet's resources and help on how to use these resources; you can access many of these resources through the hypertext references in the on line version of this series (go to http:@www.bmj.com/bmj/ to reach the electronic version). You can then explore the various methods for accessing, manipulating, or disseminating data on the Internet, such as electronic mail, telnet, file transfer protocol, and the world wide web. Results from a search of the world wide web for information on the rare condition of Recklinghausen's neurofibromatosis illustrate the breadth of medical information available on the Internet.
Hybrid quantum-classical hierarchy for mitigation of decoherence and determination of excited states
DOE Office of Scientific and Technical Information (OSTI.GOV)
McClean, Jarrod R.; Kimchi-Schwartz, Mollie E.; Carter, Jonathan
Using quantum devices supported by classical computational resources is a promising approach to quantum-enabled computation. One powerful example of such a hybrid quantum-classical approach optimized for classically intractable eigenvalue problems is the variational quantum eigensolver, built to utilize quantum resources for the solution of eigenvalue problems and optimizations with minimal coherence time requirements by leveraging classical computational resources. These algorithms have been placed as leaders among the candidates for the first to achieve supremacy over classical computation. Here, we provide evidence for the conjecture that variational approaches can automatically suppress even nonsystematic decoherence errors by introducing an exactly solvable channelmore » model of variational state preparation. Moreover, we develop a more general hierarchy of measurement and classical computation that allows one to obtain increasingly accurate solutions by leveraging additional measurements and classical resources. In conclusion, we demonstrate numerically on a sample electronic system that this method both allows for the accurate determination of excited electronic states as well as reduces the impact of decoherence, without using any additional quantum coherence time or formal error-correction codes.« less
NASA Astrophysics Data System (ADS)
Wang, Xi Vincent; Wang, Lihui
2017-08-01
Cloud computing is the new enabling technology that offers centralised computing, flexible data storage and scalable services. In the manufacturing context, it is possible to utilise the Cloud technology to integrate and provide industrial resources and capabilities in terms of Cloud services. In this paper, a function block-based integration mechanism is developed to connect various types of production resources. A Cloud-based architecture is also deployed to offer a service pool which maintains these resources as production services. The proposed system provides a flexible and integrated information environment for the Cloud-based production system. As a specific type of manufacturing, Waste Electrical and Electronic Equipment (WEEE) remanufacturing experiences difficulties in system integration, information exchange and resource management. In this research, WEEE is selected as the example of Internet of Things to demonstrate how the obstacles and bottlenecks are overcome with the help of Cloud-based informatics approach. In the case studies, the WEEE recycle/recovery capabilities are also integrated and deployed as flexible Cloud services. Supporting mechanisms and technologies are presented and evaluated towards the end of the paper.
Christensen, Paul A.; Ni, Yunyun; Bao, Feifei; Hendrickson, Heather L.; Greenwood, Michael; Thomas, Jessica S.; Long, S. Wesley; Olsen, Randall J.
2017-01-01
Introduction: Next-generation-sequencing (NGS) is increasingly used in clinical and research protocols for patients with cancer. NGS assays are routinely used in clinical laboratories to detect mutations bearing on cancer diagnosis, prognosis and personalized therapy. A typical assay may interrogate 50 or more gene targets that encompass many thousands of possible gene variants. Analysis of NGS data in cancer is a labor-intensive process that can become overwhelming to the molecular pathologist or research scientist. Although commercial tools for NGS data analysis and interpretation are available, they are often costly, lack key functionality or cannot be customized by the end user. Methods: To facilitate NGS data analysis in our clinical molecular diagnostics laboratory, we created a custom bioinformatics tool termed Houston Methodist Variant Viewer (HMVV). HMVV is a Java-based solution that integrates sequencing instrument output, bioinformatics analysis, storage resources and end user interface. Results: Compared to the predicate method used in our clinical laboratory, HMVV markedly simplifies the bioinformatics workflow for the molecular technologist and facilitates the variant review by the molecular pathologist. Importantly, HMVV reduces time spent researching the biological significance of the variants detected, standardizes the online resources used to perform the variant investigation and assists generation of the annotated report for the electronic medical record. HMVV also maintains a searchable variant database, including the variant annotations generated by the pathologist, which is useful for downstream quality improvement and research projects. Conclusions: HMVV is a clinical grade, low-cost, feature-rich, highly customizable platform that we have made available for continued development by the pathology informatics community. PMID:29226007
Kasthurirathne, Suranga N; Dixon, Brian E; Gichoya, Judy; Xu, Huiping; Xia, Yuni; Mamlin, Burke; Grannis, Shaun J
2016-04-01
Increased adoption of electronic health records has resulted in increased availability of free text clinical data for secondary use. A variety of approaches to obtain actionable information from unstructured free text data exist. These approaches are resource intensive, inherently complex and rely on structured clinical data and dictionary-based approaches. We sought to evaluate the potential to obtain actionable information from free text pathology reports using routinely available tools and approaches that do not depend on dictionary-based approaches. We obtained pathology reports from a large health information exchange and evaluated the capacity to detect cancer cases from these reports using 3 non-dictionary feature selection approaches, 4 feature subset sizes, and 5 clinical decision models: simple logistic regression, naïve bayes, k-nearest neighbor, random forest, and J48 decision tree. The performance of each decision model was evaluated using sensitivity, specificity, accuracy, positive predictive value, and area under the receiver operating characteristics (ROC) curve. Decision models parameterized using automated, informed, and manual feature selection approaches yielded similar results. Furthermore, non-dictionary classification approaches identified cancer cases present in free text reports with evaluation measures approaching and exceeding 80-90% for most metrics. Our methods are feasible and practical approaches for extracting substantial information value from free text medical data, and the results suggest that these methods can perform on par, if not better, than existing dictionary-based approaches. Given that public health agencies are often under-resourced and lack the technical capacity for more complex methodologies, these results represent potentially significant value to the public health field. Copyright © 2016 Elsevier Inc. All rights reserved.
Quantum machine learning for quantum anomaly detection
NASA Astrophysics Data System (ADS)
Liu, Nana; Rebentrost, Patrick
2018-04-01
Anomaly detection is used for identifying data that deviate from "normal" data patterns. Its usage on classical data finds diverse applications in many important areas such as finance, fraud detection, medical diagnoses, data cleaning, and surveillance. With the advent of quantum technologies, anomaly detection of quantum data, in the form of quantum states, may become an important component of quantum applications. Machine-learning algorithms are playing pivotal roles in anomaly detection using classical data. Two widely used algorithms are the kernel principal component analysis and the one-class support vector machine. We find corresponding quantum algorithms to detect anomalies in quantum states. We show that these two quantum algorithms can be performed using resources that are logarithmic in the dimensionality of quantum states. For pure quantum states, these resources can also be logarithmic in the number of quantum states used for training the machine-learning algorithm. This makes these algorithms potentially applicable to big quantum data applications.
Plasmonic ELISA for the ultrasensitive detection of disease biomarkers with the naked eye
NASA Astrophysics Data System (ADS)
de La Rica, Roberto; Stevens, Molly M.
2012-12-01
In resource-constrained countries, affordable methodologies for the detection of disease biomarkers at ultralow concentrations can potentially improve the standard of living. However, current strategies for ultrasensitive detection often require sophisticated instruments that may not be available in laboratories with fewer resources. Here, we circumvent this problem by introducing a signal generation mechanism for biosensing that enables the detection of a few molecules of analyte with the naked eye. The enzyme label of an enzyme-linked immunosorbent assay (ELISA) controls the growth of gold nanoparticles and generates coloured solutions with distinct tonality when the analyte is present. Prostate specific antigen (PSA) and HIV-1 capsid antigen p24 were detected in whole serum at the ultralow concentration of 1 × 10-18 g ml-1. p24 was also detected with the naked eye in the sera of HIV-infected patients showing viral loads undetectable by a gold standard nucleic acid-based test.
Multiplexed electronically programmable multimode ionization detector for chromatography
Wise, M.B.; Buchanan, M.V.
1988-05-19
Method and apparatus for detecting and differentiating organic compounds based on their electron affinity. An electron capture detector cell (ECD) is operated in a plurality of multiplexed electronically programmable operating modes to alter the detector response during a single sampling cycle to acquire multiple simultaneous chromatograms corresponding to each of the different operating modes. The cell is held at a constant subatmospheric pressure while the electron collection bias voltage applied to the cell is modulated electronically to allow acquisition of multiple chromatograms for a single sample elution from a chromatograph representing three distinctly different response modes. A system is provided which automatically controls the programmed application of bias pulses at different intervals and/or amplitudes to switch the detector from an ionization mode to the electron capture mode and various degrees therebetween to provide an improved means of tuning an ECD for multimode detection and improved specificity. 6 figs.
Online production validation in a HEP environment
NASA Astrophysics Data System (ADS)
Harenberg, T.; Kuhl, T.; Lang, N.; Mättig, P.; Sandhoff, M.; Schwanenberger, C.; Volkmer, F.
2017-03-01
In high energy physics (HEP) event simulations, petabytes of data are processed and stored requiring millions of CPU-years. This enormous demand for computing resources is handled by centers distributed worldwide, which form part of the LHC computing grid. The consumption of such an important amount of resources demands for an efficient production of simulation and for the early detection of potential errors. In this article we present a new monitoring framework for grid environments, which polls a measure of data quality during job execution. This online monitoring facilitates the early detection of configuration errors (specially in simulation parameters), and may thus contribute to significant savings in computing resources.
2013-12-01
effectors (deployed on ground based or aerial platforms) to detect , identify, locate, track or suppress stationary or slow moving surface based RF...ground based or aerial platforms) to detect , identify, locate, track or suppress stationary or slow moving surface based RF emitting targets. In the...Electronic Support EO Electro-Optic FPGAs Field Programmable Gate Arrays IR Infra-red LADAR Laser Detection and Ranging OSX Mac OS X; the apple
Kinase detection with gallium nitride based high electron mobility transistors
Makowski, Matthew S.; Bryan, Isaac; Sitar, Zlatko; Arellano, Consuelo; Xie, Jinqiao; Collazo, Ramon; Ivanisevic, Albena
2013-01-01
A label-free kinase detection system was fabricated by the adsorption of gold nanoparticles functionalized with kinase inhibitor onto AlGaN/GaN high electron mobility transistors (HEMTs). The HEMTs were operated near threshold voltage due to the greatest sensitivity in this operational region. The Au NP/HEMT biosensor system electrically detected 1 pM SRC kinase in ionic solutions. These results are pertinent to drug development applications associated with kinase sensing. PMID:23918992
NASA Astrophysics Data System (ADS)
Coffer, Amy Beth
Radiation imagers are import tools in the modern world for a wide range of applications. They span the use-cases of fundamental sciences, astrophysics, medical imaging, all the way to national security, nuclear safeguards, and non-proliferation verification. The type of radiation imagers studied in this thesis were gamma-ray imagers that detect emissions from radioactive materials. Gamma-ray imagers goal is to localize and map the distribution of radiation within their specific field-of-view despite the fact of complicating background radiation that can be terrestrial, astronomical, and temporal. Compton imaging systems are one type of gamma-ray imager that can map the radiation around the system without the use of collimation. Lack of collimation enables the imaging system to be able to detect radiation from all-directions, while at the same time, enables increased detection efficiency by not absorbing incident radiation in non-sensing materials. Each Compton-scatter events within an imaging system generated a possible cone-surface in space that the radiation could have originated from. Compton imaging is limited in its reconstructed image signal-to-background due to these source Compton-cones overlapping with background radiation Compton-cones. These overlapping cones limit Compton imaging's detection-sensitivity in image space. Electron-tracking Compton imaging (ETCI) can improve the detection-sensitivity by measuring the Compton-scattered electron's initial trajectory. With an estimate of the scattered electron's trajectory, one can reduce the Compton-back-projected cone to a cone-arc, thus enabling faster radiation source detection and localization. However, the ability to measure the Compton-scattered electron-trajectories adds another layer of complexity to an already complex methodology. For a real-world imaging applications, improvements are needed in electron-track detection efficiency and in electron-track reconstruction. One way of measuring Compton-scattered electron-trajectories is with high-resolution Charged-Coupled Devices (CCDs). The proof-of-principle CCD-based ETCI experiment demonstrated the CCDs' ability to measure the Compton-scattered electron-tracks as a 2-dimensional image. Electron-track-imaging algorithms using the electron-track-image are able to determine the 3-dimensional electron-track trajectory within +/- 20 degrees. The work presented here is the physics simulations developed along side the experimental proof-of-principle experiment. The development of accurate physics modeling for multiple-layer CCDs based ETCI systems allow for the accurate prediction of future ETCI system performance. The simulations also enable quick development insights for system design, and they guide the development of electron-track reconstruction methods. The physics simulation efforts for this project looked closely at the accuracy of the Geant4 Monte Carlo methods for medium energy electron transport. In older version of Geant4 there were some discrepancies between the electron-tracking experimental measurements and the simulation results. It was determined that when comparing the electron dynamics of electrons at very high resolutions, Geant4 simulations must be fine tuned with careful choices for physics production cuts and electron physics stepping sizes. One result of this work is a CCDs Monte Carlo model that has been benchmarked to experimental findings and fully characterized for both photon and electron transport. The CCDs physics model now match to within 1 percent error of experimental results for scattered-electron energies below 500 keV. Following the improvements of the CCDs simulations, the performance of a realistic two-layer CCD-stack system was characterized. The realistic CCD-stack system looked at the effect of thin passive-layers on the CCDs' front face and back-contact. The photon interaction efficiency was calculated for the two-layer CCD-stack, and we found that there is a 90 percent probability of scattered-electrons from a 662 keV source to stay within a single active layer. This demonstrates the improved detection efficiency, which is one of the strengths of the CCDs' implementation as a ETCI system. The CCD-stack simulations also established that electron-tracks scattering from one CCDs layer to another could be reconstructed. The passive-regions on the CCD-stack mean that these inter-layer scattered-electron-tracks will always loose both angular information and energy information. Looking at the angular changes of these electrons scattering between the CCDs layers showed us there is not a strong energy dependence on the angular changes due to the passive-regions of the CCDs. The angular changes of the electron track are, for the most part, a function of the thickness of the thin back-layer of the CCDs. Lastly, an approach using CCD-stack simulations was developed to reconstruct the energy transport across dead-layers and its feasibility was demonstrated. Adding back this lost energy will limit the loss of energy resolution of the scatter-interactions. Energy resolution losses would negatively impacted the achievable image resolution from image reconstruction algorithms. Returning some of the energy back to the reconstructed electron-track will help retain the expected performance of the electron-track trajectory determination algorithm.
Heat detection and compositions and devices therefor
NASA Technical Reports Server (NTRS)
Rembaum, A. (Inventor)
1975-01-01
Temperature change of a substrate such as a microelectronic component is sensed and detected by means of a mixture of a weak molecular complex of an electron donor compound such as an organic amine and an electron acceptor compound such as nitroaromatic compound. The mixture is encapsulated in a clear binder such as a vinyl resin.
An automatic lightning detection and photographic system
NASA Technical Reports Server (NTRS)
Wojtasinski, R. J.; Holley, L. D.; Gray, J. L.; Hoover, R. B.
1973-01-01
Conventional 35-mm camera is activated by an electronic signal every time lightning strikes in general vicinity. Electronic circuit detects lightning by means of antenna which picks up atmospheric radio disturbances. Camera is equipped with fish-eye lense, automatic shutter advance, and small 24-hour clock to indicate time when exposures are made.
77 FR 37926 - Petitions for Modification of Application of Existing Mandatory Safety Standards
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-25
... defined in 30 CFR 75.151 will continuously monitor for methane immediately before and during the use of... electronic testing and diagnostic equipment will not be used if methane is detected in concentrations at or above one percent. When one percent or more methane is detected while the nonpermissible electronic...