Sample records for detection limit values

  1. METHODS OF DEALING WITH VALUES BELOW THE LIMIT OF DETECTION USING SAS

    EPA Science Inventory

    Due to limitations of chemical analysis procedures, small values cannot be precisely measured. These values are said to be below the limit of detection (LOD). In statistical analyses, these values are often censored and substituted with a constant value, such as half the LOD,...

  2. METHODS OF DEALING WITH VALUES BELOW THE LIMIT OF DETECTION USING SAS

    EPA Science Inventory

    Due to limitations of chemical analysis procedures, small concentrations cannot be precisely measured. These concentrations are said to be below the limit of detection (LOD). In statistical analyses, these values are often censored and substituted with a constant value, such ...

  3. Epidemiologic Evaluation of Measurement Data in the Presence of Detection Limits

    PubMed Central

    Lubin, Jay H.; Colt, Joanne S.; Camann, David; Davis, Scott; Cerhan, James R.; Severson, Richard K.; Bernstein, Leslie; Hartge, Patricia

    2004-01-01

    Quantitative measurements of environmental factors greatly improve the quality of epidemiologic studies but can pose challenges because of the presence of upper or lower detection limits or interfering compounds, which do not allow for precise measured values. We consider the regression of an environmental measurement (dependent variable) on several covariates (independent variables). Various strategies are commonly employed to impute values for interval-measured data, including assignment of one-half the detection limit to nondetected values or of “fill-in” values randomly selected from an appropriate distribution. On the basis of a limited simulation study, we found that the former approach can be biased unless the percentage of measurements below detection limits is small (5–10%). The fill-in approach generally produces unbiased parameter estimates but may produce biased variance estimates and thereby distort inference when 30% or more of the data are below detection limits. Truncated data methods (e.g., Tobit regression) and multiple imputation offer two unbiased approaches for analyzing measurement data with detection limits. If interest resides solely on regression parameters, then Tobit regression can be used. If individualized values for measurements below detection limits are needed for additional analysis, such as relative risk regression or graphical display, then multiple imputation produces unbiased estimates and nominal confidence intervals unless the proportion of missing data is extreme. We illustrate various approaches using measurements of pesticide residues in carpet dust in control subjects from a case–control study of non-Hodgkin lymphoma. PMID:15579415

  4. USE OF METHOD DETECTION LIMITS IN ENVIRONMENTAL MEASUREMENTS

    EPA Science Inventory

    Environmental measurements often produce values below the method detection limit (MDL). Because low or zero values may be used in determining compliance with regulatory limits, in determining emission factors (typical concentrations emitted by a given type of source), or in model...

  5. 40 CFR Appendix B to Part 136 - Definition and Procedure for the Determination of the Method Detection Limit-Revision 1.11

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... calculated method detection limit. To insure that the estimate of the method detection limit is a good...) where: MDL = the method detection limit t(n-1,1- α=.99) = the students' t value appropriate for a 99... Determination of the Method Detection Limit-Revision 1.11 B Appendix B to Part 136 Protection of Environment...

  6. Censoring: a new approach for detection limits in total-reflection X-ray fluorescence

    NASA Astrophysics Data System (ADS)

    Pajek, M.; Kubala-Kukuś, A.; Braziewicz, J.

    2004-08-01

    It is shown that the detection limits in the total-reflection X-ray fluorescence (TXRF), which restrict quantification of very low concentrations of trace elements in the samples, can be accounted for using the statistical concept of censoring. We demonstrate that the incomplete TXRF measurements containing the so-called "nondetects", i.e. the non-measured concentrations falling below the detection limits and represented by the estimated detection limit values, can be viewed as the left random-censored data, which can be further analyzed using the Kaplan-Meier (KM) method correcting for nondetects. Within this approach, which uses the Kaplan-Meier product-limit estimator to obtain the cumulative distribution function corrected for the nondetects, the mean value and median of the detection limit censored concentrations can be estimated in a non-parametric way. The Monte Carlo simulations performed show that the Kaplan-Meier approach yields highly accurate estimates for the mean and median concentrations, being within a few percent with respect to the simulated, uncensored data. This means that the uncertainties of KM estimated mean value and median are limited in fact only by the number of studied samples and not by the applied correction procedure for nondetects itself. On the other hand, it is observed that, in case when the concentration of a given element is not measured in all the samples, simple approaches to estimate a mean concentration value from the data yield erroneous, systematically biased results. The discussed random-left censoring approach was applied to analyze the TXRF detection-limit-censored concentration measurements of trace elements in biomedical samples. We emphasize that the Kaplan-Meier approach allows one to estimate the mean concentrations being substantially below the mean level of detection limits. Consequently, this approach gives a new access to lower the effective detection limits for TXRF method, which is of prime interest for investigation of metallic impurities on the silicon wafers.

  7. Randomness fault detection system

    NASA Technical Reports Server (NTRS)

    Russell, B. Don (Inventor); Aucoin, B. Michael (Inventor); Benner, Carl L. (Inventor)

    1996-01-01

    A method and apparatus are provided for detecting a fault on a power line carrying a line parameter such as a load current. The apparatus monitors and analyzes the load current to obtain an energy value. The energy value is compared to a threshold value stored in a buffer. If the energy value is greater than the threshold value a counter is incremented. If the energy value is greater than a high value threshold or less than a low value threshold then a second counter is incremented. If the difference between two subsequent energy values is greater than a constant then a third counter is incremented. A fault signal is issued if the counter is greater than a counter limit value and either the second counter is greater than a second limit value or the third counter is greater than a third limit value.

  8. Effectiveness of a flow-based device using riboflavin photochemistry in damaging blood-borne viral nucleic acids.

    PubMed

    Zhu, Liguo; Tong, Hongli; Wang, Shufang; Yu, Yang; Liu, Zhong; Li, Changqing; Wang, Deqing

    2018-05-03

    Effectiveness of a flow-based treatment device using riboflavin photochemistry was demonstrated by cytopathic effect method using indicator viruses. However, inactivation efficacy against real blood-borne viruses needs to be evaluated, especially at nucleic acid level. Special plasma samples with varying concentrations of blood-borne virus were selected using a strict blood selection procedure and were treated with device treatment (DT). Nucleic acid test (NAT) using polymerase chain reaction fluorescence method was used to detect virus copies. The NAT value of 4325 in plasma with high Hepatitis B Virus (HBV) concentrations decreased to 1330 with DT. After 100-fold dilution, the NAT value was below the NAT detection limits with DT compared with 23.0 that without DT. The NAT value of 61.9 in plasma with medium HBV concentrations decreased to 37.8 with DT, and after 10-fold dilution, the NAT value was below the NAT detection limits with DT compared with below 20 that without DT. The Ct values of plasma with low concentrations of blood-borne viruses were below the NAT detection limits with DT. There was a dose effect with DT which was effective in blood-borne viruses damaging nucleic acids to a level below the NAT detection limits. Copyright © 2018 Elsevier B.V. All rights reserved.

  9. LIMITATIONS ON THE USES OF MULTIMEDIA EXPOSURE MEASUREMENTS FOR MULTIPATHWAY EXPOSURE ASSESSMENT - PART I: HANDLING OBSERVATIONS BELOW DETECTION LIMITS

    EPA Science Inventory

    Multimedia data from two probability-based exposure studies were investigated in terms of how censoring of non-detects affected estimation of population parameters and associations. Appropriate methods for handling censored below-detection-limit (BDL) values in this context were...

  10. STATISTICAL METHODS FOR ENVIRONMENTAL APPLICATIONS USING DATA SETS WITH BELOW DETECTION LIMIT OBSERVATIONS AS INCORPORTED IN PROUCL 4.0

    EPA Science Inventory

    Nondetect (ND) or below detection limit (BDL) results cannot be measured accurately, and, therefore, are reported as less than certain detection limit (DL) values. However, since the presence of some contaminants (e.g., dioxin) in environmental media may pose a threat to human he...

  11. [Exposure to organic halogen compounds in drinking water of 9 Italian regions: exposure to chlorites, chlorates, thrihalomethanes, trichloroethylene and tetrachloroethylene].

    PubMed

    Fantuzzi, G; Aggazzotti, G; Righi, E; Predieri, G; Giacobazzi, P; Kanitz, S; Barbone, F; Sansebastiano, G; Ricci, C; Leoni, V; Fabiani, L; Triassi, M

    2007-01-01

    This study investigated the exposure to organohalogens compounds in drinking water from 9 Italian towns (Udine, Genova, Parma, Modena, Siena, Roma, L'Aquila, Napoli and Catania). Overall, 1199 samples collected from 72 waterworks were analyzed. THMs, trichloroethylene and tetrachloroethylene were evaluated using the head-space gas chromatographic technique (detection limit of 0.01 microg/l; chlorite and chlorate analysis was performed by ion chromatography (detection limit of 20 microg/l). THMs were evidenced in 925 samples (77%) (median value: 1.12 micro/l; range: 0.01-54 mciro/l) and 7 were higher than the THMs Italian limit of 30 microg/l. Chlorite and chlorate levels were higher than the detection limit in 45% for chlorite and in 34% for chlorate samples; median values were 221 microg/l and 76 microg/l, respectively. Chlorite values were higher than the chlorite Italian limit (700 microg/l) in 35 samples (8.7%). Trichloroethylene and tetrachloroethylene were measured in 29% and 44% of the investigated samples and showed values lower than the Italian limit (highest levels of 6 microg/l and 9 microg/l, respectively). The low levels detected of THMs, trichloroethylene and tetrachloroethylene have no potentials effects on human health, whereas, the levels of chlorite and chlorates should be further evaluated and their potential effects for the populations using these drinking waters, better understood.

  12. Evaluation of statistical treatments of left-censored environmental data using coincident uncensored data sets: I. Summary statistics

    USGS Publications Warehouse

    Antweiler, Ronald C.; Taylor, Howard E.

    2008-01-01

    The main classes of statistical treatment of below-detection limit (left-censored) environmental data for the determination of basic statistics that have been used in the literature are substitution methods, maximum likelihood, regression on order statistics (ROS), and nonparametric techniques. These treatments, along with using all instrument-generated data (even those below detection), were evaluated by examining data sets in which the true values of the censored data were known. It was found that for data sets with less than 70% censored data, the best technique overall for determination of summary statistics was the nonparametric Kaplan-Meier technique. ROS and the two substitution methods of assigning one-half the detection limit value to censored data or assigning a random number between zero and the detection limit to censored data were adequate alternatives. The use of these two substitution methods, however, requires a thorough understanding of how the laboratory censored the data. The technique of employing all instrument-generated data - including numbers below the detection limit - was found to be less adequate than the above techniques. At high degrees of censoring (greater than 70% censored data), no technique provided good estimates of summary statistics. Maximum likelihood techniques were found to be far inferior to all other treatments except substituting zero or the detection limit value to censored data.

  13. True detection limits in an experimental linearly heteroscedastic system. Part 1

    NASA Astrophysics Data System (ADS)

    Voigtman, Edward; Abraham, Kevin T.

    2011-11-01

    Using a lab-constructed laser-excited filter fluorimeter deliberately designed to exhibit linearly heteroscedastic, additive Gaussian noise, it has been shown that accurate estimates may be made of the true theoretical Currie decision levels ( YC and XC) and true Currie detection limits ( YD and XD) for the detection of rhodamine 6 G tetrafluoroborate in ethanol. The obtained experimental values, for 5% probability of false positives and 5% probability of false negatives, were YC = 56.1 mV, YD = 125. mV, XC = 0.132 μg /mL and XD = 0.294 μg /mL. For 5% probability of false positives and 1% probability of false negatives, the obtained detection limits were YD = 158. mV and XD = 0.372 μg /mL. These decision levels and corresponding detection limits were shown to pass the ultimate test: they resulted in observed probabilities of false positives and false negatives that were statistically equivalent to the a priori specified values.

  14. Calculation of the detection limit in radiation measurements with systematic uncertainties

    NASA Astrophysics Data System (ADS)

    Kirkpatrick, J. M.; Russ, W.; Venkataraman, R.; Young, B. M.

    2015-06-01

    The detection limit (LD) or Minimum Detectable Activity (MDA) is an a priori evaluation of assay sensitivity intended to quantify the suitability of an instrument or measurement arrangement for the needs of a given application. Traditional approaches as pioneered by Currie rely on Gaussian approximations to yield simple, closed-form solutions, and neglect the effects of systematic uncertainties in the instrument calibration. These approximations are applicable over a wide range of applications, but are of limited use in low-count applications, when high confidence values are required, or when systematic uncertainties are significant. One proposed modification to the Currie formulation attempts account for systematic uncertainties within a Gaussian framework. We have previously shown that this approach results in an approximation formula that works best only for small values of the relative systematic uncertainty, for which the modification of Currie's method is the least necessary, and that it significantly overestimates the detection limit or gives infinite or otherwise non-physical results for larger systematic uncertainties where such a correction would be the most useful. We have developed an alternative approach for calculating detection limits based on realistic statistical modeling of the counting distributions which accurately represents statistical and systematic uncertainties. Instead of a closed form solution, numerical and iterative methods are used to evaluate the result. Accurate detection limits can be obtained by this method for the general case.

  15. Calculation of the detection limits for radionuclides identified in gamma-ray spectra based on post-processing peak analysis results.

    PubMed

    Korun, M; Vodenik, B; Zorko, B

    2018-03-01

    A new method for calculating the detection limits of gamma-ray spectrometry measurements is presented. The method is applicable for gamma-ray emitters, irrespective of the influences of the peaked background, the origin of the background and the overlap with other peaks. It offers the opportunity for multi-gamma-ray emitters to calculate the common detection limit, corresponding to more peaks. The detection limit is calculated by approximating the dependence of the uncertainty in the indication on its value with a second-order polynomial. In this approach the relation between the input quantities and the detection limit are described by an explicit expression and can be easy investigated. The detection limit is calculated from the data usually provided by the reports of peak-analyzing programs: the peak areas and their uncertainties. As a result, the need to use individual channel contents for calculating the detection limit is bypassed. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. ROBUST ESTIMATION OF MEAN AND VARIANCE USING ENVIRONMENTAL DATA SETS WITH BELOW DETECTION LIMIT OBSERVATIONS

    EPA Science Inventory

    Scientists, especially environmental scientists often encounter trace level concentrations that are typically reported as less than a certain limit of detection, L. Type 1, left-censored data arise when certain low values lying below L are ignored or unknown as they cannot be mea...

  17. Fabricating data: How substituting values for nondetects can ruin results, and what can be done about it

    USGS Publications Warehouse

    Helsel, D.R.

    2006-01-01

    The most commonly used method in environmental chemistry to deal with values below detection limits is to substitute a fraction of the detection limit for each nondetect. Two decades of research has shown that this fabrication of values produces poor estimates of statistics, and commonly obscures patterns and trends in the data. Papers using substitution may conclude that significant differences, correlations, and regression relationships do not exist, when in fact they do. The reverse may also be true. Fortunately, good alternative methods for dealing with nondetects already exist, and are summarized here with references to original sources. Substituting values for nondetects should be used rarely, and should generally be considered unacceptable in scientific research. There are better ways.

  18. Experimental Demonstration of Higher Precision Weak-Value-Based Metrology Using Power Recycling

    NASA Astrophysics Data System (ADS)

    Wang, Yi-Tao; Tang, Jian-Shun; Hu, Gang; Wang, Jian; Yu, Shang; Zhou, Zong-Quan; Cheng, Ze-Di; Xu, Jin-Shi; Fang, Sen-Zhi; Wu, Qing-Lin; Li, Chuan-Feng; Guo, Guang-Can

    2016-12-01

    The weak-value-based metrology is very promising and has attracted a lot of attention in recent years because of its remarkable ability in signal amplification. However, it is suggested that the upper limit of the precision of this metrology cannot exceed that of classical metrology because of the low sample size caused by the probe loss during postselection. Nevertheless, a recent proposal shows that this probe loss can be reduced by the power-recycling technique, and thus enhance the precision of weak-value-based metrology. Here we experimentally realize the power-recycled interferometric weak-value-based beam-deflection measurement and obtain the amplitude of the detected signal and white noise by discrete Fourier transform. Our results show that the detected signal can be strengthened by power recycling, and the power-recycled weak-value-based signal-to-noise ratio can surpass the upper limit of the classical scheme, corresponding to the shot-noise limit. This work sheds light on higher precision metrology and explores the real advantage of the weak-value-based metrology over classical metrology.

  19. Statistical analysis of water-quality data containing multiple detection limits: S-language software for regression on order statistics

    USGS Publications Warehouse

    Lee, L.; Helsel, D.

    2005-01-01

    Trace contaminants in water, including metals and organics, often are measured at sufficiently low concentrations to be reported only as values below the instrument detection limit. Interpretation of these "less thans" is complicated when multiple detection limits occur. Statistical methods for multiply censored, or multiple-detection limit, datasets have been developed for medical and industrial statistics, and can be employed to estimate summary statistics or model the distributions of trace-level environmental data. We describe S-language-based software tools that perform robust linear regression on order statistics (ROS). The ROS method has been evaluated as one of the most reliable procedures for developing summary statistics of multiply censored data. It is applicable to any dataset that has 0 to 80% of its values censored. These tools are a part of a software library, or add-on package, for the R environment for statistical computing. This library can be used to generate ROS models and associated summary statistics, plot modeled distributions, and predict exceedance probabilities of water-quality standards. ?? 2005 Elsevier Ltd. All rights reserved.

  20. Calculating the ankylosing spondylitis disease activity score if the conventional c-reactive protein level is below the limit of detection or if high-sensitivity c-reactive protein is used: an analysis in the DESIR cohort.

    PubMed

    Machado, Pedro; Navarro-Compán, Victoria; Landewé, Robert; van Gaalen, Floris A; Roux, Christian; van der Heijde, Désirée

    2015-02-01

    The Ankylosing Spondylitis Disease Activity Score (ASDAS) is a composite measure of disease activity in axial spondyloarthritis. The aims of this study were to determine the most appropriate method for calculating the ASDAS using the C-reactive protein (CRP) level when the conventional CRP level was below the limit of detection, to determine how low CRP values obtained by high-sensitivity CRP (hsCRP) measurement influence ASDAS-CRP results, and to test agreement between different ASDAS formulae. Patients with axial spondyloarthritis who had a conventional CRP level below the limit of detection (5 mg/liter) were selected (n = 257). The ASDAS–conventional CRP with 11 different imputations for the conventional CRP value (range 0–5 mg/liter, at 0.5-mg/liter intervals) was calculated. The ASDAS-hsCRP and ASDAS using the erythrocyte sedimentation rate (ESR) were also calculated. Agreement between the ASDAS formulae was tested. The ASDAS-hsCRP showed better agreement with the ASDAS-CRP calculated using the conventional CRP imputation values of 1.5 and 2.0 mg/liter and with the ASDAS-ESR than with other imputed formulae. Disagreement occurred mainly in lower disease activity states (inactive/moderate disease activity). When the CRP value was <2 mg/liter, the resulting ASDAS-CRP scores may have been inappropriately low. When the conventional CRP level is below the limit of detection or when the hsCRP level is <2 mg/liter, the constant value of 2 mg/liter should be used to calculate the ASDAS-CRP score. There is good agreement between the ASDAS-hsCRP and ASDAS-ESR; however, formulae are not interchangeable.

  1. Portable device for the detection of colorimetric assays

    PubMed Central

    Nowak, E.; Kawchuk, J.; Hoorfar, M.; Najjaran, H.

    2017-01-01

    In this work, a low-cost, portable device is developed to detect colorimetric assays for in-field and point-of-care (POC) analysis. The device can rapidly detect both pH values and nitrite concentrations of five different samples, simultaneously. After mixing samples with specific reagents, a high-resolution digital camera collects a picture of the sample, and a single-board computer processes the image in real time to identify the hue–saturation–value coordinates of the image. An internal light source reduces the effect of any ambient light so the device can accurately determine the corresponding pH values or nitrite concentrations. The device was purposefully designed to be low-cost, yet versatile, and the accuracy of the results have been compared to those from a conventional method. The results obtained for pH values have a mean standard deviation of 0.03 and a correlation coefficient R2 of 0.998. The detection of nitrites is between concentrations of 0.4–1.6 mg l−1, with a low detection limit of 0.2 mg l−1, and has a mean standard deviation of 0.073 and an R2 value of 0.999. The results represent great potential of the proposed portable device as an excellent analytical tool for POC colorimetric analysis and offer broad accessibility in resource-limited settings. PMID:29291093

  2. 40 CFR Appendix C to Part 425 - Definition and Procedure for the Determination of the Method Detection Limit 1

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Determination of the Method Detection Limit 1 C Appendix C to Part 425 Protection of Environment ENVIRONMENTAL... CATEGORY Pt. 425, App. C Appendix C to Part 425—Definition and Procedure for the Determination of the... reagent water. (c) The concentration value that corresponds to the region of the standard curve where...

  3. Establishing IMMULITE® 2000 cut-off values for serum allergen-specific immunoglobulin and exploring their relationship to exhaled nitric oxide

    PubMed Central

    Evjenth, Bjørg; Hansen, Tonje E; Brekke, Ole-Lars; Holt, Jan

    2014-01-01

    Aim Paediatric cut-off values for serum allergen-specific IgE (sIgE) using the Siemens IMMULITE® 2000 system to diagnose allergic rhinoconjunctivitis have not been established. We aimed to determine cut-off levels for sIgE for 10 common inhalant allergens and to study the relationship between sIgE, total IgE and fractional exhaled nitric oxide (FENO). Methods We enrolled 243 schoolchildren, including 164 with allergic rhinoconjunctivitis. Parental interviews, skin prick tests, sIgE, total IgE, FENO measurements, spirometry and exercise tests were performed. Results Cut-off values with the best combined sensitivity and specificity were above the detection limit of the assay for seven of the ten allergens (0.23–1.1 kU/L). The overall accuracy of the IMMULITE® in detecting allergic rhinoconjunctivitis was good. sIgE was superior to total IgE and FENO in predicting allergic rhinoconjunctivitis to timothy, birch, mugwort, cat, dog and house dust mite. FENO was elevated in children with allergic rhinoconjunctivitis, irrespective of asthma. Conclusion Cut-off values for sIgE were dependent on the allergic phenotype and were above the IMMULITE® detection limit for seven of ten inhalant allergens. Consequently, using the detection limit for sIgE as the decision point would result in over-diagnosing allergic rhinoconjunctivitis. When measuring elevated FENO in children, allergic rhinoconjunctivitis should be suspected. PMID:24628428

  4. Colonic polyps: application value of computer-aided detection in computed tomographic colonography.

    PubMed

    Zhang, Hui-Mao; Guo, Wei; Liu, Gui-Feng; An, Dong-Hong; Gao, Shuo-Hui; Sun, Li-Bo; Yang, Hai-Shan

    2011-02-01

    Colonic polyps are frequently encountered in clinics. Computed tomographic colonography (CTC), as a painless and quick detection, has high values in clinics. In this study, we evaluated the application value of computer-aided detection (CAD) in CTC detection of colonic polyps in the Chinese population. CTC was performed with a GE 64-row multidetector computed tomography (MDCT) scanner. Data of 50 CTC patients (39 patients positive for at least one polyp of ≥ 0.5 cm in size and the other 11 patients negative by endoscopic detection) were retrospectively reviewed first without computer-aided detection (CAD) and then with CAD by four radiologists (two were experienced and another two inexperienced) blinded to colonoscopy findings. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of detected colonic polyps, as well as the areas under the ROC curves (Az value) with and without CAD were calculated. CAD increased the overall sensitivity, specificity, positive predictive value, negative predictive value and accuracy of the colonic polyps detected by experienced and inexperienced readers. The sensitivity in detecting small polyps (5 - 9 mm) with CAD in experienced and inexperienced readers increased from 82% and 44% to 93% and 82%, respectively (P > 0.05 and P < 0.001). With the use of CAD, the overall false positive rate and false negative rate for the detection of polyps by experienced and inexperienced readers decreased in different degrees. Among 13 sessile polyps not detected by CAD, two were ≥ 1.0 cm, eleven were 5 - 9 mm in diameter, and nine were flat-shaped lesions. The application of CAD in combination with CTC can increase the ability to detect colonic polyps, particularly for inexperienced readers. However, CAD is of limited value for the detection of flat polyps.

  5. On the Determination of Uncertainty and Limit of Detection in Label-Free Biosensors.

    PubMed

    Lavín, Álvaro; Vicente, Jesús de; Holgado, Miguel; Laguna, María F; Casquel, Rafael; Santamaría, Beatriz; Maigler, María Victoria; Hernández, Ana L; Ramírez, Yolanda

    2018-06-26

    A significant amount of noteworthy articles reviewing different label-free biosensors are being published in the last years. Most of the times, the comparison among the different biosensors is limited by the procedure used of calculating the limit of detection and the measurement uncertainty. This article clarifies and establishes a simple procedure to determine the calibration function and the uncertainty of the concentration measured at any point of the measuring interval of a generic label-free biosensor. The value of the limit of detection arises naturally from this model as the limit at which uncertainty tends when the concentration tends to zero. The need to provide additional information, such as the measurement interval and its linearity, among others, on the analytical systems and biosensor in addition to the detection limit is pointed out. Finally, the model is applied to curves that are typically obtained in immunoassays and a discussion is made on the application validity of the model and its limitations.

  6. A STATISTICAL SURVEY OF DIOXIN-LIKE COMPOUNDS IN ...

    EPA Pesticide Factsheets

    The USEPA and the USDA completed the first statistically designed survey of the occurrence and concentration of dibenzo-p-dioxins (CDDs), dibenzofurans (CDFs), and coplanar polychlorinated biphenyls (PCBs) in the fat of beef animals raised for human consumption in the United States. Back fat was sampled from 63 carcasses at federally inspected slaughter establishments nationwide. The sample design called for sampling beef animal classes in proportion to national annual slaughter statistics. All samples were analyzed using a modification of EPA method 1613, using isotope dilution, High Resolution GC/MS to determine the rate of occurrence of 2,3,7,8-substituted CDDs/CDFs/PCBs. The method detection limits ranged from 0.05 ng/kg for TCDD to 3 ng/kg for OCDD. The results of this survey showed a mean concentration (reported as I-TEQ, lipid adjusted) in U.S. beef animals of 0.35 ng/kg and 0.89 ng/kg for CDD/CDF TEQs when either non-detects are treated as 0 value or assigned a value of 1/2 the detection limit, respectively, and 0.51 ng/kg for coplanar PCB TEQs at both non-detect equal 0 and 1/2 detection limit. journal article

  7. Singular value decomposition metrics show limitations of detector design in diffuse fluorescence tomography

    PubMed Central

    Leblond, Frederic; Tichauer, Kenneth M.; Pogue, Brian W.

    2010-01-01

    The spatial resolution and recovered contrast of images reconstructed from diffuse fluorescence tomography data are limited by the high scattering properties of light propagation in biological tissue. As a result, the image reconstruction process can be exceedingly vulnerable to inaccurate prior knowledge of tissue optical properties and stochastic noise. In light of these limitations, the optimal source-detector geometry for a fluorescence tomography system is non-trivial, requiring analytical methods to guide design. Analysis of the singular value decomposition of the matrix to be inverted for image reconstruction is one potential approach, providing key quantitative metrics, such as singular image mode spatial resolution and singular data mode frequency as a function of singular mode. In the present study, these metrics are used to analyze the effects of different sources of noise and model errors as related to image quality in the form of spatial resolution and contrast recovery. The image quality is demonstrated to be inherently noise-limited even when detection geometries were increased in complexity to allow maximal tissue sampling, suggesting that detection noise characteristics outweigh detection geometry for achieving optimal reconstructions. PMID:21258566

  8. A novel dicyanoisophorone based red-emitting fluorescent probe with a large Stokes shift for detection of hydrazine in solution and living cells

    NASA Astrophysics Data System (ADS)

    Lv, Hongshui; Sun, Haiyan; Wang, Shoujuan; Kong, Fangong

    2018-05-01

    A novel dicyanoisophorone based fluorescent probe HP was developed to detect hydrazine. Upon the addition of hydrazine, probe HP displayed turn-on fluorescence in the red region with a large Stokes shift (180 nm). This probe exhibited high selectivity and high sensitivity to hydrazine in solution. The detection limit of HP was found to be 3.26 ppb, which was lower than the threshold limit value set by USEPA (10 ppb). Moreover, the probe was successfully applied to detect hydrazine in different water samples and living cells.

  9. Heisenberg limit for displacements with semiclassical states

    NASA Astrophysics Data System (ADS)

    Luis, Alfredo

    2004-04-01

    We analyze the quantum limit to the sensitivity of the detection of small displacements. We focus on the case of free particles and harmonic oscillators as the systems experiencing the displacement. We show that the minimum displacement detectable is proportional to the inverse of the square root of the mean value of the energy in the state experiencing the displacement (Heisenberg limit). We present a measuring scheme that reaches this limit using semiclassical states. We examine the performance of this strategy under realistic practical conditions by computing the effect of imperfections such as losses and nonunit detection efficiencies. This analysis confirms the robustness of this measuring strategy by showing that the experimental imperfections can be suitably compensated by increasing the mean energy of the input state.

  10. The quantum limit for gravitational-wave detectors and methods of circumventing it

    NASA Technical Reports Server (NTRS)

    Thorne, K. S.; Caves, C. M.; Sandberg, V. D.; Zimmermann, M.; Drever, R. W. P.

    1979-01-01

    The Heisenberg uncertainty principle prevents the monitoring of the complex amplitude of a mechanical oscillator more accurately than a certain limit value. This 'quantum limit' is a serious obstacle to the achievement of a 10 to the -21st gravitational-wave detection sensitivity. This paper examines the principles of the back-action evasion technique and finds that this technique may be able to overcome the problem of the quantum limit. Back-action evasion does not solve, however, other problems of detection, such as weak coupling, large amplifier noise, and large Nyquist noise.

  11. Farm-specific economic value of automatic lameness detection systems in dairy cattle: From concepts to operational simulations.

    PubMed

    Van De Gucht, Tim; Saeys, Wouter; Van Meensel, Jef; Van Nuffel, Annelies; Vangeyte, Jurgen; Lauwers, Ludwig

    2018-01-01

    Although prototypes of automatic lameness detection systems for dairy cattle exist, information about their economic value is lacking. In this paper, a conceptual and operational framework for simulating the farm-specific economic value of automatic lameness detection systems was developed and tested on 4 system types: walkover pressure plates, walkover pressure mats, camera systems, and accelerometers. The conceptual framework maps essential factors that determine economic value (e.g., lameness prevalence, incidence and duration, lameness costs, detection performance, and their relationships). The operational simulation model links treatment costs and avoided losses with detection results and farm-specific information, such as herd size and lameness status. Results show that detection performance, herd size, discount rate, and system lifespan have a large influence on economic value. In addition, lameness prevalence influences the economic value, stressing the importance of an adequate prior estimation of the on-farm prevalence. The simulations provide first estimates for the upper limits for purchase prices of automatic detection systems. The framework allowed for identification of knowledge gaps obstructing more accurate economic value estimation. These include insights in cost reductions due to early detection and treatment, and links between specific lameness causes and their related losses. Because this model provides insight in the trade-offs between automatic detection systems' performance and investment price, it is a valuable tool to guide future research and developments. Copyright © 2018 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  12. Estimation of descriptive statistics for multiply censored water quality data

    USGS Publications Warehouse

    Helsel, Dennis R.; Cohn, Timothy A.

    1988-01-01

    This paper extends the work of Gilliom and Helsel (1986) on procedures for estimating descriptive statistics of water quality data that contain “less than” observations. Previously, procedures were evaluated when only one detection limit was present. Here we investigate the performance of estimators for data that have multiple detection limits. Probability plotting and maximum likelihood methods perform substantially better than simple substitution procedures now commonly in use. Therefore simple substitution procedures (e.g., substitution of the detection limit) should be avoided. Probability plotting methods are more robust than maximum likelihood methods to misspecification of the parent distribution and their use should be encouraged in the typical situation where the parent distribution is unknown. When utilized correctly, less than values frequently contain nearly as much information for estimating population moments and quantiles as would the same observations had the detection limit been below them.

  13. Sensitive, fast, and specific immunoassays for methyltestosterone detection.

    PubMed

    Kong, Na; Song, Shanshan; Peng, Juan; Liu, Liqiang; Kuang, Hua; Xu, Chuanlai

    2015-04-29

    An indirect competitive enzyme-linked immunosorbent assay (icELISA) and an immunochromatographic strip assay using a highly specific monoclonal antibody, were developed to detect methyltestosterone (MT) residues in animal feed. The optimized icELISA had a half-inhibition concentration value of 0.26 ng/mL and a limit of detection value of 0.045 ng/mL. There was no cross-reactivity with eight analogues, revealing high specificity for MT. Based on icELISA results, the recovery rate of MT in animal feed was 82.4%-100.6%. The results were in accordance with those obtained by gas chromatography-mass spectrometry. The developed immunochromatographic strip assay, as the first report for MT detection, had a visual cut-off value of 1 ng/mL in PBS, 2.5 ng/g in fish feed, and 2.5 ng/g in pig feed. Therefore, these immunoassays are useful and fast tools for MT residue detection in animal feed.

  14. True detection limits in an experimental linearly heteroscedastic system.. Part 2

    NASA Astrophysics Data System (ADS)

    Voigtman, Edward; Abraham, Kevin T.

    2011-11-01

    Despite much different processing of the experimental fluorescence detection data presented in Part 1, essentially the same estimates were obtained for the true theoretical Currie decision levels ( YC and XC) and true Currie detection limits ( YD and XD). The obtained experimental values, for 5% probability of false positives and 5% probability of false negatives, were YC = 56.0 mV, YD = 125. mV, XC = 0.132 μg/mL and XD = 0.293 μg/mL. For 5% probability of false positives and 1% probability of false negatives, the obtained detection limits were YD = 158 . mV and XD = 0.371 μg/mL. Furthermore, by using bootstrapping methodology on the experimental data for the standards and the analytical blank, it was possible to validate previously published experimental domain expressions for the decision levels ( yC and xC) and detection limits ( yD and xD). This was demonstrated by testing the generated decision levels and detection limits for their performance in regard to false positives and false negatives. In every case, the obtained numbers of false negatives and false positives were as specified a priori.

  15. Functionalized gold nanoparticles for the detection of arsenic in water.

    PubMed

    Domínguez-González, R; González Varela, L; Bermejo-Barrera, P

    2014-01-01

    Gold nanoparticles are attractive as sensing materials because of their size and shape are related with their optical properties. The color change produced by the aggregation of functionalized AuNPs allows the detection of arsenic at low levels. A simple, cheap and fast analytical procedure to perform arsenic determination using functionalized gold nanoparticles (AuNPs) and VIS spectrometry as a detection technique is studied. Three different synthesis procedures to obtain the AuNPs and two different functionalization modes were studied. AuNPs functionalized with GSH-DTT-CYs-PDCA were selected as the most adequate. The correlation between the decrease in the absorbance signal and the arsenic concentration was good in the 2-20 µg l(-1)interval. Repeatability, expressed as average of RSD (%), obtained for the different arsenic concentrations studied was 0.6%. The average value of the analytical recovery was 99.7%. The detection and quantifications limits were 2.5 and 8.4 µg l(-1) respectively. These limits are sufficient to detect World Health Organization's guideline value of 10 µg l(-1). © 2013 Published by Elsevier B.V.

  16. Enhanced Detectability of Community Structure in Multilayer Networks through Layer Aggregation.

    PubMed

    Taylor, Dane; Shai, Saray; Stanley, Natalie; Mucha, Peter J

    2016-06-03

    Many systems are naturally represented by a multilayer network in which edges exist in multiple layers that encode different, but potentially related, types of interactions, and it is important to understand limitations on the detectability of community structure in these networks. Using random matrix theory, we analyze detectability limitations for multilayer (specifically, multiplex) stochastic block models (SBMs) in which L layers are derived from a common SBM. We study the effect of layer aggregation on detectability for several aggregation methods, including summation of the layers' adjacency matrices for which we show the detectability limit vanishes as O(L^{-1/2}) with increasing number of layers, L. Importantly, we find a similar scaling behavior when the summation is thresholded at an optimal value, providing insight into the common-but not well understood-practice of thresholding pairwise-interaction data to obtain sparse network representations.

  17. First Detected Arrival of a Quantum Walker on an Infinite Line

    NASA Astrophysics Data System (ADS)

    Thiel, Felix; Barkai, Eli; Kessler, David A.

    2018-01-01

    The first detection of a quantum particle on a graph is shown to depend sensitively on the distance ξ between the detector and initial location of the particle, and on the sampling time τ . Here, we use the recently introduced quantum renewal equation to investigate the statistics of first detection on an infinite line, using a tight-binding lattice Hamiltonian with nearest-neighbor hops. Universal features of the first detection probability are uncovered and simple limiting cases are analyzed. These include the large ξ limit, the small τ limit, and the power law decay with the attempt number of the detection probability over which quantum oscillations are superimposed. For large ξ the first detection probability assumes a scaling form and when the sampling time is equal to the inverse of the energy band width nonanalytical behaviors arise, accompanied by a transition in the statistics. The maximum total detection probability is found to occur for τ close to this transition point. When the initial location of the particle is far from the detection node we find that the total detection probability attains a finite value that is distance independent.

  18. Large strain cruciform biaxial testing for FLC detection

    NASA Astrophysics Data System (ADS)

    Güler, Baran; Efe, Mert

    2017-10-01

    Selection of proper test method, specimen design and analysis method are key issues for studying formability of sheet metals and detection of their forming limit curves (FLC). Materials with complex microstructures may need an additional micro-mechanical investigation and accurate modelling. Cruciform biaxial test stands as an alternative to standard tests as it achieves frictionless, in-plane, multi-axial stress states with a single sample geometry. In this study, we introduce a small-scale (less than 10 cm) cruciform sample allowing micro-mechanical investigation at stress states ranging from plane strain to equibiaxial. With successful specimen design and surface finish, large forming limit strains are obtained at the test region of the sample. The large forming limit strains obtained by experiments are compared to the values obtained from Marciniak-Kuczynski (M-K) local necking model and Cockroft-Latham damage model. This comparison shows that the experimental limiting strains are beyond the theoretical values, approaching to the fracture strain of the two test materials: Al-6061-T6 aluminum alloy and DC-04 high formability steel.

  19. Assessment of average of normals (AON) procedure for outlier-free datasets including qualitative values below limit of detection (LoD): an application within tumor markers such as CA 15-3, CA 125, and CA 19-9.

    PubMed

    Usta, Murat; Aral, Hale; Mete Çilingirtürk, Ahmet; Kural, Alev; Topaç, Ibrahim; Semerci, Tuna; Hicri Köseoğlu, Mehmet

    2016-11-01

    Average of normals (AON) is a quality control procedure that is sensitive only to systematic errors that can occur in an analytical process in which patient test results are used. The aim of this study was to develop an alternative model in order to apply the AON quality control procedure to datasets that include qualitative values below limit of detection (LoD). The reported patient test results for tumor markers, such as CA 15-3, CA 125, and CA 19-9, analyzed by two instruments, were retrieved from the information system over a period of 5 months, using the calibrator and control materials with the same lot numbers. The median as a measure of central tendency and the median absolute deviation (MAD) as a measure of dispersion were used for the complementary model of AON quality control procedure. The u bias values, which were determined for the bias component of the measurement uncertainty, were partially linked to the percentages of the daily median values of the test results that fall within the control limits. The results for these tumor markers, in which lower limits of reference intervals are not medically important for clinical diagnosis and management, showed that the AON quality control procedure, using the MAD around the median, can be applied for datasets including qualitative values below LoD.

  20. Analysis of abamectin residues in avocados by high-performance liquid chromatography with fluorescence detection.

    PubMed

    Hernández-Borges, Javier; Ravelo-Pérez, Lidia M; Hernández-Suárez, Estrella M; Carnero, Aurelio; Rodríguez-Delgado, Miguel Angel

    2007-09-21

    In this work an analytical method for the determination of abamectin residues in avocados is developed using high-performance liquid chromatography (HPLC) with fluorescence (FL) detection. A pre-column derivatization with trifluoroacetic anhydride (TFAA) and N-methylimidazole (NMIM) was carried out. The mobile phase consisted of water, methanol and acetonitrile (5:47.5:47.5 v/v/v) and was pumped at a rate of 1 mL/min (isocratic elution). The fluorescence detector was set at an excitation wavelength of 365 nm and an emission wavelength of 470 nm. Homogenized avocado samples were extracted twice with acetonitrile:water 8:2 (v/v) and cleaned using C(18) solid-phase extraction (SPE) cartridges. Recovery values were in the range 87-98% with RSD values lower than 13%. The limits of detection (LODs) and quantification (LOQs) of the whole method were 0.001 and 0.003 mg/kg, respectively. These values are lower than the maximum residue limit (MRL) established by the European Union (EU) and the Spanish legislation in avocado samples.

  1. Improved detection of multiple environmental antibiotics through an optimized sample extraction strategy in liquid chromatography-mass spectrometry analysis.

    PubMed

    Yi, Xinzhu; Bayen, Stéphane; Kelly, Barry C; Li, Xu; Zhou, Zhi

    2015-12-01

    A solid-phase extraction/liquid chromatography/electrospray ionization/multi-stage mass spectrometry (SPE-LC-ESI-MS/MS) method was optimized in this study for sensitive and simultaneous detection of multiple antibiotics in urban surface waters and soils. Among the seven classes of tested antibiotics, extraction efficiencies of macrolides, lincosamide, chloramphenicol, and polyether antibiotics were significantly improved under optimized sample extraction pH. Instead of only using acidic extraction in many existing studies, the results indicated that antibiotics with low pK a values (<7) were extracted more efficiently under acidic conditions and antibiotics with high pK a values (>7) were extracted more efficiently under neutral conditions. The effects of pH were more obvious on polar compounds than those on non-polar compounds. Optimization of extraction pH resulted in significantly improved sample recovery and better detection limits. Compared with reported values in the literature, the average reduction of minimal detection limits obtained in this study was 87.6% in surface waters (0.06-2.28 ng/L) and 67.1% in soils (0.01-18.16 ng/g dry wt). This method was subsequently applied to detect antibiotics in environmental samples in a heavily populated urban city, and macrolides, sulfonamides, and lincomycin were frequently detected. Antibiotics with highest detected concentrations were sulfamethazine (82.5 ng/L) in surface waters and erythromycin (6.6 ng/g dry wt) in soils. The optimized sample extraction strategy can be used to improve the detection of a variety of antibiotics in environmental surface waters and soils.

  2. [Detection of antibodies against Legionella pneumophila from pleural effusion--a case report of Legionnaire's pneumonia with pleural effusion].

    PubMed

    Xu, L; Wang, P; Chen, S

    1994-06-01

    Using TAT and ELISA, 50 samples of pleural effusion and sera from patients infected with non-Legionella pneumophila were detected for antibodies against Legionella pneumophila serogroups 1 and 6, respectively. The average titre and upper limit value (99%, mean + 2.326S) calculated. In addition, a pleural effusion and a serum from a patient with Legionnaire's pneumonia were also detected by TAT and ELISA. The result showed that the titre of this antibody in his pleural effusion was not only over the upper limit, but also higher than that in his serum.

  3. Resolution Limits of Nanoimprinted Patterns by Fluorescence Microscopy

    NASA Astrophysics Data System (ADS)

    Kubo, Shoichi; Tomioka, Tatsuya; Nakagawa, Masaru

    2013-06-01

    The authors investigated optical resolution limits to identify minimum distances between convex lines of fluorescent dye-doped nanoimprinted resist patterns by fluorescence microscopy. Fluorescent ultraviolet (UV)-curable resin and thermoplastic resin films were transformed into line-and-space patterns by UV nanoimprinting and thermal nanoimprinting, respectively. Fluorescence immersion observation needed an immersion medium immiscible to the resist films, and an ionic liquid of triisobutyl methylphosphonium tosylate was appropriate for soluble thermoplastic polystyrene patterns. Observation with various numerical aperture (NA) values and two detection wavelength ranges showed that the resolution limits were smaller than the values estimated by the Sparrow criterion. The space width to identify line patterns became narrower as the line width increased. The space width of 100 nm was demonstrated to be sufficient to resolve 300-nm-wide lines in the detection wavelength range of 575-625 nm using an objective lens of NA= 1.40.

  4. Censoring approach to the detection limits in X-ray fluorescence analysis

    NASA Astrophysics Data System (ADS)

    Pajek, M.; Kubala-Kukuś, A.

    2004-10-01

    We demonstrate that the effect of detection limits in the X-ray fluorescence analysis (XRF), which limits the determination of very low concentrations of trace elements and results in appearance of the so-called "nondetects", can be accounted for using the statistical concept of censoring. More precisely, the results of such measurements can be viewed as the left random censored data, which can further be analyzed using the Kaplan-Meier method correcting the data for the presence of nondetects. Using this approach, the results of measured, detection limit censored concentrations can be interpreted in a nonparametric manner including the correction for the nondetects, i.e. the measurements in which the concentrations were found to be below the actual detection limits. Moreover, using the Monte Carlo simulation technique we show that by using the Kaplan-Meier approach the corrected mean concentrations for a population of the samples can be estimated within a few percent uncertainties with respect of the simulated, uncensored data. This practically means that the final uncertainties of estimated mean values are limited in fact by the number of studied samples and not by the correction procedure itself. The discussed random-left censoring approach was applied to analyze the XRF detection-limit-censored concentration measurements of trace elements in biomedical samples.

  5. Human exposure to metals: levels in autopsy tissues of individuals living near a hazardous waste incinerator.

    PubMed

    Mari, Montse; Nadal, Martí; Schuhmacher, Marta; Barbería, Eneko; García, Francisco; Domingo, José L

    2014-06-01

    The concentrations of a number of metals were determined in the brain, bone, kidney, liver, and lung of 20 autopsied subjects who had lived, at least 10 years, in the neighborhood of a hazardous waste incinerator (HWI) in Tarragona (Catalonia, Spain). Results were compared with those obtained in 1998 (baseline survey) and previous surveys (2003 and 2007). Arsenic, Be, Ni, Tl, and V showed concentrations below the corresponding detection limits in all tissues. Cadmium showed the highest levels in the kidney, with a mean value of 21.15 μg/g. However, Cd was found below the detection limit in the brain and bone. Chromium showed similar concentrations in the kidney, brain, and lung (range of mean values, 0.57-0.66 μg/g) and higher in the bone (1.38 μg/g). In turn, Hg was below the detection limit in all tissues with the exception of the kidney, where the mean concentration was 0.15 μg/g (range, <0.05-0.58 μg/g). On the other hand, Mn could be detected in all tissues showing the highest levels in the liver and kidney (1.45 and 1.09 μg/g, respectively). Moreover, Pb showed the highest concentrations in bone (mean, 1.39 μg/g; range, <0.025-4.88 μg/g). Finally, Sn could be detected only in some tissue samples, reaching the highest values in the bone (0.17 μg/g). The current metal levels in human tissues from individuals living near the HWI of Tarragona are comparable and of a similar magnitude to previously reported results corresponding to general populations, as well as those of our previous surveys.

  6. Determination of Total Petroleum Hydrocarbons in Australian Groundwater Through the Improvised Gas Chromatography-Flame Ionization Detection Technique.

    PubMed

    Faustorilla, Maria Vilma; Chen, Zuliang; Dharmarajan, Rajarathnam; Naidu, Ravendra

    2017-09-01

    Assessment of total petroleum hydrocarbons (TPHs) from contaminated sites demands routine and reliable measurement at trace levels. However, the detection limits of these methods need to be improved. This study developed the programmable temperature vaporization-large volume injection (PTV-LVI) method to quantify TPHs through gas chromatography-flame ionization detection. This configuration enhances the method sensitivity for trace level detections through large volume injections and pre-concentration of analytes along the injection liner. The method was evaluated for the three commonly observed hydrocarbon fractions: C10-C14, C15-C28 and C29-C36. In comparison with conventional injection methods (splitless and pulsed splitless), PTV-LVI showed R2 values > 0.999 with enhanced limits of detection and limits of quantification values. The method was applied to real samples for routine environmental monitoring of TPHs in an Australian contaminated site characterized by refueling station. Analysis of groundwater samples in the area showed a wide range of TPH concentrations as follows: 66-1,546,000 (C10-C14), 216-22,762 (C15-C28) and 105-2,103 (C29-C36) μg/L. This method has detected trace levels, thereby measuring a wider concentration range of TPHs. These more accurate measurements can lead to the appropriate application of risk assessments and remediation techniques. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  7. Quartz-Seq2: a high-throughput single-cell RNA-sequencing method that effectively uses limited sequence reads.

    PubMed

    Sasagawa, Yohei; Danno, Hiroki; Takada, Hitomi; Ebisawa, Masashi; Tanaka, Kaori; Hayashi, Tetsutaro; Kurisaki, Akira; Nikaido, Itoshi

    2018-03-09

    High-throughput single-cell RNA-seq methods assign limited unique molecular identifier (UMI) counts as gene expression values to single cells from shallow sequence reads and detect limited gene counts. We thus developed a high-throughput single-cell RNA-seq method, Quartz-Seq2, to overcome these issues. Our improvements in the reaction steps make it possible to effectively convert initial reads to UMI counts, at a rate of 30-50%, and detect more genes. To demonstrate the power of Quartz-Seq2, we analyzed approximately 10,000 transcriptomes from in vitro embryonic stem cells and an in vivo stromal vascular fraction with a limited number of reads.

  8. Use of recombinant calreticulin and cercarial transformation fluid (CTF) in the serodiagnosis of Schistosoma mansoni.

    PubMed

    El Aswad, Bahaa El Deen Wade; Doenhoff, Michael J; El Hadidi, Abeer Shawky; Schwaeble, Wilhelm J; Lynch, Nicholas J

    2011-03-01

    Schistosomiasis is traditionally diagnosed by microscopic detection of ova in stool samples, but this method is labour intensive and its sensitivity is limited by low and variable egg secretion in many patients. An alternative is an ELISA using Schistosoma mansoni soluble egg antigen (SEA) to detect anti-schistosome antibody in patient samples. SEA is a good diagnostic marker in non-endemic regions but is of limited value in endemic regions, mainly because of its high cost and limited specificity. Here we assess seven novel antigens for the detection of S. mansoni antibody in an endemic region (the Northern Nile Delta). Using recombinant S. mansoni calreticulin (CRT) and fragments thereof, anti-CRT antibodies were detected in the majority of 97 patients sera. The diagnostic value of some of these antigens was, however, limited by the presence of cross-reacting antibody in the healthy controls, even those recruited in non-endemic areas. Cercarial transformation fluid (CTF), a supernatant that contains soluble material released by the cercariae upon transformation to the schistosomula, is cheaper and easier to produce than SEA. An ELISA using CTF as the detection antigen had a sensitivity of 89.7% and an estimated specificity of 100% when used in non-endemic regions, matching the performance of the established SEA ELISA. CTF was substantially more specific than SEA for diagnosis in the endemic region, and less susceptible than SEA to cross-reacting antibody in the sera of controls with other protozoan and metazoan infections. Copyright © 2010 Elsevier GmbH. All rights reserved.

  9. Detection Limits for Spectro-fluorometry: A Case Study in the Region of Finstersee, Canton Zug, Northern Switzerland

    NASA Astrophysics Data System (ADS)

    Otz, M. H.; Otz, H. K.; Keller, P.

    2002-05-01

    Synthetic fluorescent dyes, applied below the visual detection limit (< 0.1 mg/L), have been used as tracers of ground water flow paths since the beginning of the 1950s. Since 1965, we have used spectro-fluorometers with photomultipliers to measure low concentrations of fluorescent dyes in ground water in Switzerland. In collaboration with the Engineering Geology Department of the ETH, we have separated uranine at 0.1 ng/L and Na-naphtionate at 1 ng/L from background fluorescence of spring water in the Finstersee region. These values are 10-100 times lower than postulated detection limits in the literature. The use of low dye concentrations prevents a study region from being contaminated by increased background levels due to remnant dye within the aquifer, thereby leaving the region available for future dye tracing studies. Lower detection limits also can solve particular hydraulic problems where conventional methods fail and enhance the possibility for using artificial dyes in environmentally sensitive aquifer settings.

  10. Solvent cleaning of pole transformers containing PCB contaminated insulating oil.

    PubMed

    Kanbe, H; Shibuya, M

    2001-01-01

    In 1989, it was discovered that the recycled insulation oil in pole transformers for electric power supply was contaminated with trace amounts of polychlorinated biphenyls (PCBs; maximum 50 mg-PCB/kg-insulation oil). In order to remove the PCBs from transformer components using n-hexane as a solvent, we investigated the relationship between progressive stages of dismantling and cleaning results. The results are summarized as follows: (1) Based on the cleaning test results, we made an estimate of the residual PCB amount on iron and copper components. By dismantling the test pole transformers into the "iron core and coil portion" and cleaning the components, we achieved a residual PCB amount that was below the limit of detection (0.05 mg-PCB/kg-material). To achieve a residual PCB amount below the limit of detection for the transformer paper component, it was necessary to cut the paper into pieces smaller than 5 mm. We were unable to achieve a residual PCB amount below the limit of detection for the wood component. (2) Compared to Japan's stipulated limited concentration standard values for PCBs, the results of the cleaning test show that cleaning iron or copper components with PCBs only on their surface with the solvent n-hexane will satisfy the limited concentration standard values when care is taken to ensure the component surfaces have adequate contact with the cleaning solvent.

  11. Evaluation of Beckman Coulter DxI 800 immunoassay system using clinically oriented performance goals.

    PubMed

    Akbas, Neval; Schryver, Patricia G; Algeciras-Schimnich, Alicia; Baumann, Nikola A; Block, Darci R; Budd, Jeffrey R; Gaston, S J Stephen; Klee, George G

    2014-11-01

    We evaluated the analytical performance of 24 immunoassays using the Beckman Coulter DxI 800 immunoassay systems at Mayo Clinic, Rochester, MN for trueness, precision, detection limits, linearity, and consistency (across instruments and reagent lots). Clinically oriented performance goals were defined using the following methods: trueness-published desirable accuracy limits, precision-published desirable biologic variation; detection limits - 0.1 percentile of patient test values, linearity - 50% of total error, and consistency-percentage test values crossing key decision points. Local data were collected for precision, linearity, and consistency. Data were provided by Beckman Coulter, Inc. for trueness and detection limits. All evaluated assays except total thyroxine were within the proposed goals for trueness. Most of the assays met the proposed goals for precision (86% of intra-assay results and 75% of inter-assay results). Five assays had more than 15% of the test results below the minimum detection limits. Carcinoembryonic antigen, total thyroxine and free triiodothyronine exceeded the proposed goals of ±6.3%, ±5% and ±5.7% for dilution linearity. All evaluated assays were within the proposed goals for instrument consistency. Lot-to-lot consistency results for cortisol, ferritin and total thyroxine exceeded the proposed goals of 3.3%, 11.4% and 7% at one medical decision level, while vitamin B12 exceeded the proposed goals of 5.2% and 3.8% at two decision levels. The Beckman Coulter DxI 800 immunoassay system meets most of these proposed goals, even though these clinically focused performance goals represent relatively stringent limits. Copyright © 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  12. [Data distribution and transformation in population based sampling survey of viral load in HIV positive men who have sex with men in China].

    PubMed

    Dou, Z; Chen, J; Jiang, Z; Song, W L; Xu, J; Wu, Z Y

    2017-11-10

    Objective: To understand the distribution of population viral load (PVL) data in HIV infected men who have sex with men (MSM), fit distribution function and explore the appropriate estimating parameter of PVL. Methods: The detection limit of viral load (VL) was ≤ 50 copies/ml. Box-Cox transformation and normal distribution tests were used to describe the general distribution characteristics of the original and transformed data of PVL, then the stable distribution function was fitted with test of goodness of fit. Results: The original PVL data fitted a skewed distribution with the variation coefficient of 622.24%, and had a multimodal distribution after Box-Cox transformation with optimal parameter ( λ ) of-0.11. The distribution of PVL data over the detection limit was skewed and heavy tailed when transformed by Box-Cox with optimal λ =0. By fitting the distribution function of the transformed data over the detection limit, it matched the stable distribution (SD) function ( α =1.70, β =-1.00, γ =0.78, δ =4.03). Conclusions: The original PVL data had some censored data below the detection limit, and the data over the detection limit had abnormal distribution with large degree of variation. When proportion of the censored data was large, it was inappropriate to use half-value of detection limit to replace the censored ones. The log-transformed data over the detection limit fitted the SD. The median ( M ) and inter-quartile ranger ( IQR ) of log-transformed data can be used to describe the centralized tendency and dispersion tendency of the data over the detection limit.

  13. Accounting for undetected compounds in statistical analyses of mass spectrometry 'omic studies.

    PubMed

    Taylor, Sandra L; Leiserowitz, Gary S; Kim, Kyoungmi

    2013-12-01

    Mass spectrometry is an important high-throughput technique for profiling small molecular compounds in biological samples and is widely used to identify potential diagnostic and prognostic compounds associated with disease. Commonly, this data generated by mass spectrometry has many missing values resulting when a compound is absent from a sample or is present but at a concentration below the detection limit. Several strategies are available for statistically analyzing data with missing values. The accelerated failure time (AFT) model assumes all missing values result from censoring below a detection limit. Under a mixture model, missing values can result from a combination of censoring and the absence of a compound. We compare power and estimation of a mixture model to an AFT model. Based on simulated data, we found the AFT model to have greater power to detect differences in means and point mass proportions between groups. However, the AFT model yielded biased estimates with the bias increasing as the proportion of observations in the point mass increased while estimates were unbiased with the mixture model except if all missing observations came from censoring. These findings suggest using the AFT model for hypothesis testing and mixture model for estimation. We demonstrated this approach through application to glycomics data of serum samples from women with ovarian cancer and matched controls.

  14. The optimum measurement precision evaluation for blood components using near-infrared spectra on 1000-2500 nm

    NASA Astrophysics Data System (ADS)

    Zhang, Ziyang; Sun, Di; Han, Tongshuai; Guo, Chao; Liu, Jin

    2016-10-01

    In the non-invasive blood components measurement using near infrared spectroscopy, the useful signals caused by the concentration variation in the interested components, such as glucose, hemoglobin, albumin etc., are relative weak. Then the signals may be greatly disturbed by a lot of noises in various ways. We improved the signals by using the optimum path-length for the used wavelength to get a maximum variation of transmitted light intensity when the concentration of a component varies. And after the path-length optimization for every wavelength in 1000-2500 nm, we present the detection limits for the components, including glucose, hemoglobin and albumin, when measuring them in a tissue phantom. The evaluated detection limits could be the best reachable precision level since it assumed the measurement uses a high signal-to-noise ratio (SNR) signal and the optimum path-length. From the results, available wavelengths in 1000-2500 nm for the three component measurements can be screened by comparing their detection limit values with their measurement limit requirements. For other blood components measurement, the evaluation their detection limits could also be designed using the method proposed in this paper. Moreover, we use an equation to estimate the absorbance at the optimum path-length for every wavelength in 1000-2500 nm caused by the three components. It could be an easy way to realize the evaluation because adjusting the sample cell's size to the precise path-length value for every wavelength is not necessary. This equation could also be referred to other blood components measurement using the optimum path-length for every used wavelength.

  15. High-throughput method for macrolides and lincosamides antibiotics residues analysis in milk and muscle using a simple liquid-liquid extraction technique and liquid chromatography-electrospray-tandem mass spectrometry analysis (LC-MS/MS).

    PubMed

    Jank, Louise; Martins, Magda Targa; Arsand, Juliana Bazzan; Campos Motta, Tanara Magalhães; Hoff, Rodrigo Barcellos; Barreto, Fabiano; Pizzolato, Tânia Mara

    2015-11-01

    A fast and simple method for residue analysis of the antibiotics classes of macrolides (erythromycin, azithromycin, tylosin, tilmicosin and spiramycin) and lincosamides (lincomycin and clindamycin) was developed and validated for cattle, swine and chicken muscle and for bovine milk. Sample preparation consists in a liquid-liquid extraction (LLE) with acetonitrile, followed by liquid chromatography-electrospray-tandem mass spectrometry analysis (LC-ESI-MS/MS), without the need of any additional clean-up steps. Chromatographic separation was achieved using a C18 column and a mobile phase composed by acidified acetonitrile and water. The method was fully validated according the criteria of the Commission Decision 2002/657/EC. Validation parameters such as limit of detection, limit of quantification, linearity, accuracy, repeatability, specificity, reproducibility, decision limit (CCα) and detection capability (CCβ) were evaluated. All calculated values met the established criteria. Reproducibility values, expressed as coefficient of variation, were all lower than 19.1%. Recoveries range from 60% to 107%. Limits of detection were from 5 to 25 µg kg(-1).The present method is able to be applied in routine analysis, with adequate time of analysis, low cost and a simple sample preparation protocol. Copyright © 2015. Published by Elsevier B.V.

  16. A community detection algorithm using network topologies and rule-based hierarchical arc-merging strategies

    PubMed Central

    2017-01-01

    The authors use four criteria to examine a novel community detection algorithm: (a) effectiveness in terms of producing high values of normalized mutual information (NMI) and modularity, using well-known social networks for testing; (b) examination, meaning the ability to examine mitigating resolution limit problems using NMI values and synthetic networks; (c) correctness, meaning the ability to identify useful community structure results in terms of NMI values and Lancichinetti-Fortunato-Radicchi (LFR) benchmark networks; and (d) scalability, or the ability to produce comparable modularity values with fast execution times when working with large-scale real-world networks. In addition to describing a simple hierarchical arc-merging (HAM) algorithm that uses network topology information, we introduce rule-based arc-merging strategies for identifying community structures. Five well-studied social network datasets and eight sets of LFR benchmark networks were employed to validate the correctness of a ground-truth community, eight large-scale real-world complex networks were used to measure its efficiency, and two synthetic networks were used to determine its susceptibility to two resolution limit problems. Our experimental results indicate that the proposed HAM algorithm exhibited satisfactory performance efficiency, and that HAM-identified and ground-truth communities were comparable in terms of social and LFR benchmark networks, while mitigating resolution limit problems. PMID:29121100

  17. Nanoparticle size detection limits by single particle ICP-MS for 40 elements.

    PubMed

    Lee, Sungyun; Bi, Xiangyu; Reed, Robert B; Ranville, James F; Herckes, Pierre; Westerhoff, Paul

    2014-09-02

    The quantification and characterization of natural, engineered, and incidental nano- to micro-size particles are beneficial to assessing a nanomaterial's performance in manufacturing, their fate and transport in the environment, and their potential risk to human health. Single particle inductively coupled plasma mass spectrometry (spICP-MS) can sensitively quantify the amount and size distribution of metallic nanoparticles suspended in aqueous matrices. To accurately obtain the nanoparticle size distribution, it is critical to have knowledge of the size detection limit (denoted as Dmin) using spICP-MS for a wide range of elements (other than a few available assessed ones) that have been or will be synthesized into engineered nanoparticles. Herein is described a method to estimate the size detection limit using spICP-MS and then apply it to nanoparticles composed of 40 different elements. The calculated Dmin values correspond well for a few of the elements with their detectable sizes that are available in the literature. Assuming each nanoparticle sample is composed of one element, Dmin values vary substantially among the 40 elements: Ta, U, Ir, Rh, Th, Ce, and Hf showed the lowest Dmin values, ≤10 nm; Bi, W, In, Pb, Pt, Ag, Au, Tl, Pd, Y, Ru, Cd, and Sb had Dmin in the range of 11-20 nm; Dmin values of Co, Sr, Sn, Zr, Ba, Te, Mo, Ni, V, Cu, Cr, Mg, Zn, Fe, Al, Li, and Ti were located at 21-80 nm; and Se, Ca, and Si showed high Dmin values, greater than 200 nm. A range of parameters that influence the Dmin, such as instrument sensitivity, nanoparticle density, and background noise, is demonstrated. It is observed that, when the background noise is low, the instrument sensitivity and nanoparticle density dominate the Dmin significantly. Approaches for reducing the Dmin, e.g., collision cell technology (CCT) and analyte isotope selection, are also discussed. To validate the Dmin estimation approach, size distributions for three engineered nanoparticle samples were obtained using spICP-MS. The use of this methodology confirms that the observed minimum detectable sizes are consistent with the calculated Dmin values. Overall, this work identifies the elements and nanoparticles to which current spICP-MS approaches can be applied, in order to enable quantification of very small nanoparticles at low concentrations in aqueous media.

  18. Development of ochratoxin a in cereal by chemiluminescence enzyme immunoassay

    NASA Astrophysics Data System (ADS)

    Li, Min; Liu, Renrong; Zhu, Lixin; Chen, Zhenzhen

    2017-11-01

    A rapid, simple and sensitive chemiluminescence enzyme immunoassay method (CLEIA) was established to detect ochratoxin A (OTA) in cereal. Optimal conditions including antibody dilution ratio and enzyme conjugate, ionic strength, pH value and organic solvent. Established indirect competition inhibition curve to determine the linear working range, detection limit and recovery rate. Results: The 50% inhibitory concentration and the detection limit of the CLEIA were78.8pg/mL and 14.86 pg/mL, respectively, with a linear range of 0.015-0.4ng/mL. At 1∼4μpg/kg fortified levels in wheat, mean recoveries ranged from 67.47% to100.35%.

  19. Colorimetric and fluorescent detection of hydrazine with high sensitivity and excellent selectivity

    NASA Astrophysics Data System (ADS)

    Shi, Bingjie; Qi, Sujie; Yu, Mingming; Liu, Chunxia; Li, Zhanxian; Wei, Liuhe; Ni, Zhonghai

    2018-01-01

    It is critical to develop probes for rapid, selective, and sensitive detection of the highly toxic hydrazine in both environmental and biological science. In this work, under mild condition, a novel colorimetric and off-on fluorescent probe was synthesized for rapid recognition of hydrazine with excellent selectivity over other various species including some biological species, metal ions and anions. The limit of quantification (LOQ) value was 1.5 × 10- 4 M-3.2 × 10- 3 M (colorimetric method) and 1.5 × 10- 4 M - 3.2 × 10- 3 M (fluorescent method) with as low as detection limit of 46.2 μM.

  20. Fluorescence Immunoassay for Cocaine Detection.

    PubMed

    Nakayama, Hiroshi; Kenjjou, Noriko; Shigetoh, Nobuyuki; Ito, Yuji

    2016-04-01

    A fluorescence immunoassay (FIA) has been developed for the detection of cocaine using norcocaine labeled with merocyanine dye and a monoclonal antibody specific to cocaine. Using this FIA, the detection range for cocaine was between 20.0 and 1700 μg/L with a limit of detection of 20.0 μg/L. Other cocaine derivatives did not interfere significantly with the detection when using this immunoassay technique with cross-reactivity values of less than 20%. Thus this FIA could be considered a useful tool for the detection of cocaine.

  1. An accurate and inexpensive color-based assay for detecting severe anemia in a limited-resource setting

    PubMed Central

    McGann, Patrick T.; Tyburski, Erika A.; de Oliveira, Vysolela; Santos, Brigida; Ware, Russell E.; Lam, Wilbur A.

    2016-01-01

    Severe anemia is an important cause of morbidity and mortality among children in resource-poor settings, but laboratory diagnostics are often limited in these locations. To address this need, we developed a simple, inexpensive, and color-based point-of-care (POC) assay to detect severe anemia. The purpose of this study was to evaluate the accuracy of this novel POC assay to detect moderate and severe anemia in a limited-resource setting. The study was a cross-sectional study conducted on children with sickle cell anemia in Luanda, Angola. The hemoglobin concentrations obtained by the POC assay were compared to reference values measured by a calibrated automated hematology analyzer. A total of 86 samples were analyzed (mean hemoglobin concentration 6.6 g/dL). There was a strong correlation between the hemoglobin concentrations obtained by the POC assay and reference values obtained from an automated hematology analyzer (r=0.88, P<0.0001). The POC assay demonstrated excellent reproducibility (r=0.93, P<0.0001) and the reagents appeared to be durable in a tropical setting (r=0.93, P<0.0001). For the detection of severe anemia that may require blood transfusion (hemoglobin <5 g/dL), the POC assay had sensitivity of 88.9% and specificity of 98.7%. These data demonstrate that an inexpensive (<$0.25 USD) POC assay accurately estimates low hemoglobin concentrations and has the potential to become a transformational diagnostic tool for severe anemia in limited-resource settings. PMID:26317494

  2. DetectTLC: Automated Reaction Mixture Screening Utilizing Quantitative Mass Spectrometry Image Feature

    PubMed Central

    Kaddi, Chanchala D.; Bennett, Rachel V.; Paine, Martin R. L.; Banks, Mitchel D.; Weber, Arthur L.; Fernández, Facundo M.; Wang, May D.

    2016-01-01

    Full characterization of complex reaction mixtures is necessary to understand mechanisms, optimize yields, and elucidate secondary reaction pathways. Molecular-level information for species in such mixtures can be readily obtained by coupling mass spectrometry imaging (MSI) with thin layer chromatography (TLC) separations. User-guided investigation of imaging data for mixture components with known m/z values is generally straightforward; however, spot detection for unknowns is highly tedious, and limits the applicability of MSI in conjunction with TLC. To accelerate imaging data mining, we developed DetectTLC, an approach that automatically identifies m/z values exhibiting TLC spot-like regions in MS molecular images. Furthermore, DetectTLC can also spatially match m/z values for spots acquired during alternating high and low collision-energy scans, pairing product ions with precursors to enhance structural identification. As an example, DetectTLC is applied to the identification and structural confirmation of unknown, yet significant, products of abiotic pyrazinone and aminopyrazine nucleoside analog synthesis. PMID:26508443

  3. Sensitive, Fast, and Specific Immunoassays for Methyltestosterone Detection

    PubMed Central

    Kong, Na; Song, Shanshan; Peng, Juan; Liu, Liqiang; Kuang, Hua; Xu, Chuanlai

    2015-01-01

    An indirect competitive enzyme-linked immunosorbent assay (icELISA) and an immunochromatographic strip assay using a highly specific monoclonal antibody, were developed to detect methyltestosterone (MT) residues in animal feed. The optimized icELISA had a half-inhibition concentration value of 0.26 ng/mL and a limit of detection value of 0.045 ng/mL. There was no cross-reactivity with eight analogues, revealing high specificity for MT. Based on icELISA results, the recovery rate of MT in animal feed was 82.4%–100.6%. The results were in accordance with those obtained by gas chromatography-mass spectrometry. The developed immunochromatographic strip assay, as the first report for MT detection, had a visual cut-off value of 1 ng/mL in PBS, 2.5 ng/g in fish feed, and 2.5 ng/g in pig feed. Therefore, these immunoassays are useful and fast tools for MT residue detection in animal feed. PMID:25938198

  4. Small values in big data: The continuing need for appropriate metadata

    USGS Publications Warehouse

    Stow, Craig A.; Webster, Katherine E.; Wagner, Tyler; Lottig, Noah R.; Soranno, Patricia A.; Cha, YoonKyung

    2018-01-01

    Compiling data from disparate sources to address pressing ecological issues is increasingly common. Many ecological datasets contain left-censored data – observations below an analytical detection limit. Studies from single and typically small datasets show that common approaches for handling censored data — e.g., deletion or substituting fixed values — result in systematic biases. However, no studies have explored the degree to which the documentation and presence of censored data influence outcomes from large, multi-sourced datasets. We describe left-censored data in a lake water quality database assembled from 74 sources and illustrate the challenges of dealing with small values in big data, including detection limits that are absent, range widely, and show trends over time. We show that substitutions of censored data can also bias analyses using ‘big data’ datasets, that censored data can be effectively handled with modern quantitative approaches, but that such approaches rely on accurate metadata that describe treatment of censored data from each source.

  5. Normal values of urine total protein- and albumin-to-creatinine ratios in term newborns.

    PubMed

    El Hamel, Chahrazed; Chianea, Thierry; Thon, Séverine; Lepichoux, Anne; Yardin, Catherine; Guigonis, Vincent

    2017-01-01

    It is important to have an accurate assessment of urinary protein when glomerulopathy or kidney injury is suspected. Currently available normal values for the neonate population have limited value, in part because they are based on small populations and obsolete creatinine assays. We have performed a prospective study with the aim to update the normal upper values of the urinary total protein-to-creatinine and albumin-to-creatinine ratios in term newborns. Urine samples were collected from 277 healthy, full-term newborns within the first 48 hours (D0-1) and between 72 and 120 h of life (D3-4). Total protein, albumin, creatinine and osmolality were measured and the upper limit of normal (upper-limit) values determined. At D0-1 and D3-4, the upper-limit values for the total protein-to-creatinine ratio were 1431 and 1205 mg/g (162 and 136 g/mol) and those for the albumin-to-creatinine ratio were 746 and 301 mg/g (84 and 34 g/mol), respectively. The upper-limit values were significantly higher at D0-1 than at D3-4 only for the albumin-to-creatinine ratio. This study determined the upper limit of normal values for urinary total protein-to-creatinine and albumin-to-creatinine ratios in the largest population of newborns studied to date. These values can therefore be considered as the most clinically relevant data currently available for the detection and diagnosis of glomerular injury in daily clinical practice in this population.

  6. Verification of spectrophotometric method for nitrate analysis in water samples

    NASA Astrophysics Data System (ADS)

    Kurniawati, Puji; Gusrianti, Reny; Dwisiwi, Bledug Bernanti; Purbaningtias, Tri Esti; Wiyantoko, Bayu

    2017-12-01

    The aim of this research was to verify the spectrophotometric method to analyze nitrate in water samples using APHA 2012 Section 4500 NO3-B method. The verification parameters used were: linearity, method detection limit, level of quantitation, level of linearity, accuracy and precision. Linearity was obtained by using 0 to 50 mg/L nitrate standard solution and the correlation coefficient of standard calibration linear regression equation was 0.9981. The method detection limit (MDL) was defined as 0,1294 mg/L and limit of quantitation (LOQ) was 0,4117 mg/L. The result of a level of linearity (LOL) was 50 mg/L and nitrate concentration 10 to 50 mg/L was linear with a level of confidence was 99%. The accuracy was determined through recovery value was 109.1907%. The precision value was observed using % relative standard deviation (%RSD) from repeatability and its result was 1.0886%. The tested performance criteria showed that the methodology was verified under the laboratory conditions.

  7. Detection of β-Lactams and Chloramphenicol Residues in Raw Milk-Development and Application of an HPLC-DAD Method in Comparison with Microbial Inhibition Assays.

    PubMed

    Karageorgou, Eftychia; Christoforidou, Sofia; Ioannidou, Maria; Psomas, Evdoxios; Samouris, Georgios

    2018-06-01

    The present study was carried out to assess the detection sensitivity of four microbial inhibition assays (MIAs) in comparison with the results obtained by the High Performance Liquid Chromatography with Diode-Array Detection (HPLC-DAD) method for antibiotics of the β-lactam group and chloramphenicol in fortified raw milk samples. MIAs presented fairly good results when detecting β-lactams, whereas none were able to detect chloramphenicol at or above the permissible limits. HPLC analysis revealed high recoveries of examined compounds, whereas all detection limits observed were lower than their respective maximum residue limits (MRL) values. The extraction and clean-up procedure of antibiotics was performed by a modified matrix solid phase dispersion procedure using a mixture of Plexa by Agilent and QuEChERS as a sorbent. The HPLC method developed was validated, determining the accuracy, precision, linearity, decision limit, and detection capability. Both methods were used to monitor raw milk samples of several cows and sheep, obtained from producers in different regions of Greece, for the presence of examined antibiotic residues. Results obtained showed that MIAs could be used effectively and routinely to detect antibiotic residues in several milk types. However, in some cases, spoilage of milk samples revealed that the kits' sensitivity could be strongly affected, whereas this fact does not affect the effectiveness of HPLC-DAD analysis.

  8. Supercritical fluid chromatography with photodiode array detection for pesticide analysis in papaya and avocado samples.

    PubMed

    Pano-Farias, Norma S; Ceballos-Magaña, Silvia G; Gonzalez, Jorge; Jurado, José M; Muñiz-Valencia, Roberto

    2015-04-01

    To improve the analysis of pesticides in complex food matrices with economic importance, alternative chromatographic techniques, such as supercritical fluid chromatography, can be used. Supercritical fluid chromatography has barely been applied for pesticide analysis in food matrices. In this paper, an analytical method using supercritical fluid chromatography coupled to a photodiode array detection has been established for the first time for the quantification of pesticides in papaya and avocado. The extraction of methyl parathion, atrazine, ametryn, carbofuran, and carbaryl was performed through the quick, easy, cheap, effective, rugged, and safe methodology. The method was validated using papaya and avocado samples. For papaya, the correlation coefficient values were higher than 0.99; limits of detection and quantification ranged from 130-380 and 220-640 μg/kg, respectively; recovery values ranged from 72.8-94.6%; precision was lower than 3%. For avocado, limit of detection values were ˂450 μg/kg; precision was lower than 11%; recoveries ranged from 50.0-94.2%. Method feasibility was tested for lime, banana, mango, and melon samples. Our results demonstrate that the proposed method is applicable to methyl parathion, atrazine, ametryn, and carbaryl, toxics pesticides used worldwide. The methodology presented in this work could be applicable to other fruits. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Gravitational wave emission from oscillating millisecond pulsars

    NASA Astrophysics Data System (ADS)

    Alford, Mark G.; Schwenzer, Kai

    2015-02-01

    Neutron stars undergoing r-mode oscillation emit gravitational radiation that might be detected on the Earth. For known millisecond pulsars the observed spin-down rate imposes an upper limit on the possible gravitational wave signal of these sources. Taking into account the physics of r-mode evolution, we show that only sources spinning at frequencies above a few hundred Hertz can be unstable to r-modes, and we derive a more stringent universal r-mode spin-down limit on their gravitational wave signal. We find that this refined bound limits the gravitational wave strain from millisecond pulsars to values below the detection sensitivity of next generation detectors. Young sources are therefore a more promising option for the detection of gravitational waves emitted by r-modes and to probe the interior composition of compact stars in the near future.

  10. Detecting long-duration cloud contamination in hyper-temporal NDVI imagery

    NASA Astrophysics Data System (ADS)

    Ali, Amjad; de Bie, C. A. J. M.; Skidmore, A. K.

    2013-10-01

    Cloud contamination impacts on the quality of hyper-temporal NDVI imagery and its subsequent interpretation. Short-duration cloud impacts are easily removed by using quality flags and an upper envelope filter, but long-duration cloud contamination of NDVI imagery remains. In this paper, an approach that goes beyond the use of quality flags and upper envelope filtering is tested to detect when and where long-duration clouds are responsible for unreliable NDVI readings, so that a user can flag those data as missing. The study is based on MODIS Terra and the combined Terra-Aqua 16-day NDVI product for the south of Ghana, where persistent cloud cover occurs throughout the year. The combined product could be assumed to have less cloud contamination, since it is based on two images per day. Short-duration cloud effects were removed from the two products through using the adaptive Savitzky-Golay filter. Then for each 'cleaned' product an unsupervised classified map was prepared using the ISODATA algorithm, and, by class, plots were prepared to depict changes over time of the means and the standard deviations in NDVI values. By comparing plots of similar classes, long-duration cloud contamination appeared to display a decline in mean NDVI below the lower limit 95% confidence interval with a coinciding increase in standard deviation above the upper limit 95% confidence interval. Regression analysis was carried out per NDVI class in two randomly selected groups in order to statistically test standard deviation values related to long-duration cloud contamination. A decline in seasonal NDVI values (growing season) were below the lower limit of 95% confidence interval as well as a concurrent increase in standard deviation values above the upper limit of the 95% confidence interval were noted in 34 NDVI classes. The regression analysis results showed that differences in NDVI class values between the Terra and the Terra-Aqua imagery were significantly correlated (p < 0.05) with the corresponding standard deviation values of the Terra imagery in case of all NDVI classes of two selected NDVI groups. The method successfully detects long-duration cloud contamination that results in unreliable NDVI values. The approach offers scientists interested in time series analysis a method of masking by area (class) the periods when pre-cleaned NDVI values remain affected by clouds. The approach requires no additional data for execution purposes but involves unsupervised classification of the imagery to carry out the evaluation of class-specific mean NDVI and standard deviation values over time.

  11. A Modified Tri-Exponential Model for Multi-b-value Diffusion-Weighted Imaging: A Method to Detect the Strictly Diffusion-Limited Compartment in Brain

    PubMed Central

    Zeng, Qiang; Shi, Feina; Zhang, Jianmin; Ling, Chenhan; Dong, Fei; Jiang, Biao

    2018-01-01

    Purpose: To present a new modified tri-exponential model for diffusion-weighted imaging (DWI) to detect the strictly diffusion-limited compartment, and to compare it with the conventional bi- and tri-exponential models. Methods: Multi-b-value diffusion-weighted imaging (DWI) with 17 b-values up to 8,000 s/mm2 were performed on six volunteers. The corrected Akaike information criterions (AICc) and squared predicted errors (SPE) were calculated to compare these three models. Results: The mean f0 values were ranging 11.9–18.7% in white matter ROIs and 1.2–2.7% in gray matter ROIs. In all white matter ROIs: the AICcs of the modified tri-exponential model were the lowest (p < 0.05 for five ROIs), indicating the new model has the best fit among these models; the SPEs of the bi-exponential model were the highest (p < 0.05), suggesting the bi-exponential model is unable to predict the signal intensity at ultra-high b-value. The mean ADCvery−slow values were extremely low in white matter (1–7 × 10−6 mm2/s), but not in gray matter (251–445 × 10−6 mm2/s), indicating that the conventional tri-exponential model fails to represent a special compartment. Conclusions: The strictly diffusion-limited compartment may be an important component in white matter. The new model fits better than the other two models, and may provide additional information. PMID:29535599

  12. Determination of 2,3,7,8-chlorine-substituted dibenzo-p-dioxins and -furans at the part per trillion level in United States beef fat using high-resolution gas chromatography/high-resolution mass spectrometry

    NASA Technical Reports Server (NTRS)

    Ferrario, J.; Byrne, C.; McDaniel, D.; Dupuy, A. Jr; Harless, R.

    1996-01-01

    As part of the U.S. EPA Dioxin Reassessment Program, the 2,3,7,8-chlorine-substituted dibenzo-p-dioxins and furans were measured at part per trillion (ppt) levels in beef fat collected from slaughter facilities in the United States. This is the first statistically designed national survey of these compounds in the U.S. beef supply. Analyte concentrations were determined by high-resolution gas chromatography/high-resolution mass spectrometry, using isotope dilution methodology. Method limits of detection on a whole weight basis were 0.05 ppt for TCDD and 0.10 ppt for TCDF, 0.50 ppt for the pentas (PeCDDs/PeCDFs)/hexas (HxCDDs/HxCDFs)/heptas (HpCDDs/HpCDFs), and 3.00 ppt for the octas (OCDD/OCDF). Method detection and quantitation limits were established on the basis of demonstrated performance criteria utilizing fortified samples rather than by conventional signal-to-noise or variability of response methods. The background subtraction procedures developed for this study minimized the likelihood of false positives and increased the confidence associated with reported values near the detection limits. Mean and median values for each of the 2,3,7,8-Cl-substituted dioxins and furans are reported, along with the supporting information required for their interpretation. The mean toxic equivalence values for the samples are 0.35 ppt (nondetects = 0) and 0.89 ppt (nondetects = 1/2 LOD).

  13. Determination of bisphenol A in food-simulating liquids using LCED with a chemically modified electrode.

    PubMed

    D'Antuono, A; Dall'Orto, V C; Lo Balbo, A; Sobral, S; Rezzano, I

    2001-03-01

    Liquid chromatography with electrochemical detector (LC-ED), using a chemically modified electrode coated with a metalloporphyrin film, is reported for determination of bisphenol A (BPA) migration from polycarbonate baby bottles. The extraction process of the samples was performed according to regulations of the Southern Common Market (MERCOSUR), where certain food-simulating liquids [(A) distilled water, (B) acetic acid 3% V/V in distilled water, and (C) ethanol 15% V/V in distilled water] are defined along with controlled time and temperature conditions. The baseline obtained using the naked electrode showed a considerable drift which increased the detection limit. This effect was suppressed with the chemically modified electrode. A linear range up to 450 ppb along with a detection limit of 20 ppb for the amperometric detection technique was observed. The procedure described herein allowed lowering the detection limit of the method to 0.2 ppb. The value found for BPA in the food-simulating liquid is 1.2 ppb, which is below the tolerance limit for specific migration (4.8 ppm).

  14. Aflatoxin M1 Concentration in Various Dairy Products: Evidence for Biologically Reduced Amount of AFM1 in Yoghurt

    PubMed Central

    RAHIMIRAD, Amir; MAALEKINEJAD, Hassan; OSTADI, Araz; YEGANEH, Samal; FAHIMI, Samira

    2014-01-01

    Abstract Background Aflatoxin M1 (AFM1), a carcinogenic substance is found in milk and dairy products. The effect of season and type of dairy products on AFMi level in northern Iran was investigated in this study. Methods Three hundred samples (each season 75 samples) including raw and pasteurized milk, yoghurt, cheese, and cream samples were collected from three distinct milk producing farms. The samples were subjected to chemical and solid phase extractions and were analyzed by using HPLC technique. Recovery percentages, limit of detection and limit of quantification values were determined. Results Seventy percent and 98% were the minimum and maximum recoveries for cheese and raw milk, respectively and 0.021 and 0.063 ppb were the limit of detection and limit of quantification values for AFM1. We found that in autumn and winter the highest level (0.121 ppb) of AFM1 in cheese and cream samples and failed to detect any AFM1 in spring samples. Interestingly, our data showed that the yoghurt samples had the lowest level of AFM1 in all seasons. Conclusion There are significant differences between the AFM1 levels in dairy products in various seasons and also various types of products, suggesting spring and summer yoghurt samples as the safest products from AFM1 level point of view. PMID:25927044

  15. Life expectancy and the value of early detection.

    PubMed

    Howard, David H

    2005-09-01

    This paper presents a model of the benefits and costs of early detection of asymptomatic disease as they vary by age. The benefits of early detection tend toward zero as the risk of death from competing causes increases. Costs per detected case also decline with age, assuming that disease incidence rises with age, but are always strictly positive. On balance, there is always an age limit beyond which the costs associated with early detection outweigh the benefits. Application of the model to prostate cancer screening suggests that early detection above age 70 or so is not cost-effective.

  16. Total Acid Value Titration of Hydrotreated Biomass Fast Pyrolysis Oil: Determination of Carboxylic Acids and Phenolics with Multiple End-Point Detection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Christensen, E.; Alleman, T. L.; McCormick, R. L.

    Total acid value titration has long been used to estimate corrosive potential of petroleum crude oil and fuel oil products. The method commonly used for this measurement, ASTM D664, utilizes KOH in isopropanol as the titrant with potentiometric end point determination by pH sensing electrode and Ag/AgCl reference electrode with LiCl electrolyte. A natural application of the D664 method is titration of pyrolysis-derived bio-oil, which is a candidate for refinery upgrading to produce drop in fuels. Determining the total acid value of pyrolysis derived bio-oil has proven challenging and not necessarily amenable to the methodology employed for petroleum products duemore » to the different nature of acids present. We presented an acid value titration for bio-oil products in our previous publication which also utilizes potentiometry using tetrabutylammonium hydroxide in place of KOH as the titrant and tetraethylammonium bromide in place of LiCl as the reference electrolyte to improve the detection of these types of acids. This method was shown to detect numerous end points in samples of bio-oil that were not detected by D664. These end points were attributed to carboxylic acids and phenolics based on the results of HPLC and GC-MS studies. Additional work has led to refinement of the method and it has been established that both carboxylic acids and phenolics can be determined accurately. Use of pH buffer calibration to determine half-neutralization potentials of acids in conjunction with the analysis of model compounds has allowed us to conclude that this titration method is suitable for the determination of total acid value of pyrolysis oil and can be used to differentiate and quantify weak acid species. The measurement of phenolics in bio-oil is subject to a relatively high limit of detection, which may limit the utility of titrimetric methodology for characterizing the acidic potential of pyrolysis oil and products.« less

  17. The clinical performance evaluation of novel protein chips for eleven biomarkers detection and the diagnostic model study.

    PubMed

    Luo, Yuan; Zhu, Xu; Zhang, Pengjun; Shen, Qian; Wang, Zi; Wen, Xinyu; Wang, Ling; Gao, Jing; Dong, Jin; Yang, Caie; Wu, Tangming; Zhu, Zheng; Tian, Yaping

    2015-01-01

    We aimed to develop and validate two novel protein chips, which are based on microarray chemiluminescence immunoassay and can simultaneously detected 11 biomarkers, and then to evaluate their clinical diagnostic value by comparing with the traditional methods. Protein chips were evaluated for limit of detection, specificity, common interferences, linearity, precision and accuracy. 11 biomarkers were simultaneously detected by traditional methods and protein chips in 3683 samples, which included 1723 cancer patients, 1798 benign diseases patients and 162 healthy controls. After assay validation, protein chips demonstrated high sensitivity, high specificity, good linearity, low imprecision and were free of common interferences. Compared with the traditional methods, protein chips have good correlation in the detection of all the 13 kinds of biomarkers (r≥0.935, P<0.001). For specific cancer detection, there were no statistically significant differences between the traditional method and novel protein chips, except that male protein chip showed significantly better diagnostic value on NSE detection (P=0.004) but significantly worse value on pro-GRP detection (P=0.012), female chip showed significantly better diagnostic value on pro-GRP detection (P=0.005). Furthermore, both male and female multivariate diagnostic models had significantly better diagnostic value than single detection of PGI, PG II, pro-GRP, NSE and CA125 (P<0.05). In addition, male models had significantly better diagnostic value than single CA199 and free-PSA (P<0.05), while female models observed significantly better diagnostic value than single CA724 and β-HCG (P<0.05). For total disease or cancer detection, the AUC of multivariate logistic regression for the male and female disease detection was 0.981 (95% CI: 0.975-0.987) and 0.836 (95% CI: 0.798-0.874), respectively. While, that for total cancer detection was 0.691 (95% CI: 0.666-0.717) and 0.753 (95% CI: 0.731-0.775), respectively. The new designed protein chips are simple, multiplex and reliable clinical assays and the multi-parameter diagnostic models based on them could significantly improve their clinical performance.

  18. The clinical performance evaluation of novel protein chips for eleven biomarkers detection and the diagnostic model study

    PubMed Central

    Luo, Yuan; Zhu, Xu; Zhang, Pengjun; Shen, Qian; Wang, Zi; Wen, Xinyu; Wang, Ling; Gao, Jing; Dong, Jin; Yang, Caie; Wu, Tangming; Zhu, Zheng; Tian, Yaping

    2015-01-01

    We aimed to develop and validate two novel protein chips, which are based on microarray chemiluminescence immunoassay and can simultaneously detected 11 biomarkers, and then to evaluate their clinical diagnostic value by comparing with the traditional methods. Protein chips were evaluated for limit of detection, specificity, common interferences, linearity, precision and accuracy. 11 biomarkers were simultaneously detected by traditional methods and protein chips in 3683 samples, which included 1723 cancer patients, 1798 benign diseases patients and 162 healthy controls. After assay validation, protein chips demonstrated high sensitivity, high specificity, good linearity, low imprecision and were free of common interferences. Compared with the traditional methods, protein chips have good correlation in the detection of all the 13 kinds of biomarkers (r≥0.935, P<0.001). For specific cancer detection, there were no statistically significant differences between the traditional method and novel protein chips, except that male protein chip showed significantly better diagnostic value on NSE detection (P=0.004) but significantly worse value on pro-GRP detection (P=0.012), female chip showed significantly better diagnostic value on pro-GRP detection (P=0.005). Furthermore, both male and female multivariate diagnostic models had significantly better diagnostic value than single detection of PGI, PG II, pro-GRP, NSE and CA125 (P<0.05). In addition, male models had significantly better diagnostic value than single CA199 and free-PSA (P<0.05), while female models observed significantly better diagnostic value than single CA724 and β-HCG (P<0.05). For total disease or cancer detection, the AUC of multivariate logistic regression for the male and female disease detection was 0.981 (95% CI: 0.975-0.987) and 0.836 (95% CI: 0.798-0.874), respectively. While, that for total cancer detection was 0.691 (95% CI: 0.666-0.717) and 0.753 (95% CI: 0.731-0.775), respectively. The new designed protein chips are simple, multiplex and reliable clinical assays and the multi-parameter diagnostic models based on them could significantly improve their clinical performance. PMID:26884957

  19. The determination of levofloxacin by flow injection analysis using UV detection, potentiometry, and conductometry in pharmaceutical preparations.

    PubMed

    Altiokka, G; Atkosar, Z; Can, N O

    2002-10-15

    A flow injection analysis (FIA) using UV detection, potentiometry and conductometry for levofloxacin (LVF) are described in this study. The best solvent system was found to consist of 0.2 M acetate buffer at pH 3 having 10% MeOH. A flow rate of 1 ml min(-1) was pumped and active material was detected at 288 nm. The detection limit (LOD) and limit of quantification (LOQ) for FIA were calculated to be 3 x 10(-7) M (S/N = 3) and 1 x 10(-7) M (S/N = 10), respectively. In the analysis of tablets, the RSD values were found to be 0.83, 0.98 and 0.99 for FIA, potentiometric and conductometric methods, respectively. Copyright 2002 Elsevier Science B.V.

  20. Online detection and quantification of ergot bodies in cereals using near infrared hyperspectral imaging.

    PubMed

    Vermeulen, Ph; Pierna, J A Fernández; Egmond, H P van; Dardenne, P; Baeten, V

    2012-01-01

    The occurrence of ergot bodies (sclerotia of Claviceps purpurea) in cereals presents a high toxicity risk for animals and humans due to the alkaloid content. To reduce this risk, the European Commission fixed an ergot concentration limit of 0.1% in all feedstuffs containing unground cereals, and a limit of 0.05% in 'intervention' cereals destined for humans. This study sought to develop a procedure based on near infrared hyperspectral imaging and multivariate image analysis to detect and quantify ergot contamination in cereals. Hyperspectral images were collected using an NIR hyperspectral line scan combined with a conveyor belt. All images consisted of lines of 320 pixels that were acquired at 209 wavelength channels (1100-2400 nm). To test the procedure, several wheat samples with different levels of ergot contamination were prepared. The results showed a correlation higher than 0.99 between the predicted values obtained using chemometric tools such as partial least squares discriminant analysis or support vector machine and the reference values. For a wheat sample with a level of ergot contamination as low as 0.01 %, it was possible to identify groups of pixels detected as ergot to conclude that the sample was contaminated. In addition, no false positives were obtained with non-contaminated samples. The limit of detection was found to be 145 mg/kg and the limit of quantification 341 mg/kg. The reproducibility tests of the measurements performed over several weeks showed that the results were always within the limits allowed. Additional studies were done to optimise the parameters in terms of number of samples analysed per unit of time or conveyor belt speed. It was shown that ergot can be detected using a speed of 1-100 mm/s and that a sample of 250 g can be analysed in 1 min.

  1. The upper values of plasma creatine kinase of professional soccer players during the Brazilian National Championship.

    PubMed

    Lazarim, Fernanda L; Antunes-Neto, Joaquim M F; da Silva, Fernando O C; Nunes, Lázaro A S; Bassini-Cameron, Adriana; Cameron, Luiz-Cláudio; Alves, Armindo A; Brenzikofer, René; de Macedo, Denise Vaz

    2009-01-01

    The current schedule of the Brazilian Soccer Championship may not give players enough recovery time between games. This could increase the chances of muscle damage and impaired performance. We hypothesized that plasma creatine kinase (CK) activity could be a reliable indirect marker of muscle overload in soccer players, so we sought to identify the reference values for upper limits of CK activity during a real-life elite competition. This study analyzed changes in plasma CK activity in 128 professional soccer players at different times during the Brazilian Championship. The upper limits of the 97.5th and 90th percentiles determined for CK activity were 1.338U/L and 975U/L, respectively, markedly higher than values previously reported in the literature. We also evaluated a team monthly throughout the Championship. The upper limit of the 90th percentile, 975U/L, was taken as the decision limit. Six players showing plasma CK values higher than this were asked to decrease their training for 1 week. These players presented lower CK values afterwards. Only one player with a CK value higher than the decision limit (1800U/L 1 day before a game) played on the field and was unfortunately injured during the game. The CK activity in all the other players showed a significant decrease over the course of the Championship, and the values became more homogeneous at the end. The results presented here suggest that plasma CK upper limit values can be used as a practical alternative for early detection of muscle overload in competing soccer players.

  2. Comparative elemental analysis of fine particulate matter (PM2.5) from industrial and residential areas in Greater Cairo-Egypt by means of a multi-secondary target energy dispersive X-ray fluorescence spectrometer

    NASA Astrophysics Data System (ADS)

    Shaltout, Abdallah A.; Hassan, Salwa K.; Karydas, Andreas G.; Zaki, Z. I.; Mostafa, Nasser Y.; Kregsamer, Peter; Wobrauschek, Peter; Streli, Christina

    2018-07-01

    Fine aerosol particles with aerodynamic diameter equal or <2.5 μm (PM2.5) have been collected from industrial and residential areas of Greater Cairo, Egypt during two different seasons namely; autumn 2014 and winter 2014/2015. Energy dispersive X-ray fluorescence (EDXRF) analysis utilizing polarization geometry and three different secondary targets (CaF2, Ge, and Mo) was employed for the quantitative analysis of eighteen (18) elements in PM2.5 samples. Light elements like Na and Mg was possible to be quantified, whereas detection limits in the range of few ng m-3 were attained for the most of the detected elements. Although, the average mass concentrations of the PM2.5 collected from the residential area (27 ± 7 μg m-3) is close to the annual mean limit value, a significant number of the collected samples (33%) presented higher average mass concentrations. For the industrial location, the average mass concentration is equal to 55 ± 19 μg m-3, exceeded twofold the annual mean limit value of the European Commission. Remarkably high elemental concentrations were determined for the most of the detected elements from the industrial area samples, clearly indicating the significant influence of anthropogenic activities. The present optimized EDXRF analysis offered significantly improved analytical range and limits of detection with respect to previous similar studies, thus enhancing our knowledge and understanding on the contribution of different pollution sources.

  3. Performance limitations of label-free sensors in molecular diagnosis using complex samples

    NASA Astrophysics Data System (ADS)

    Varma, Manoj

    2016-03-01

    Label-free biosensors promised a paradigm involving direct detection of biomarkers from complex samples such as serum without requiring multistep sample processing typical of labelled methods such as ELISA or immunofluorescence assays. Label-free sensors have witnessed decades of development with a veritable zoo of techniques available today exploiting a multitude of physical effects. It is appropriate now to critically assess whether label-free technologies have succeeded in delivering their promise with respect to diagnostic applications, particularly, ambitious goals such as early cancer detection using serum biomarkers, which require low limits of detection (LoD). Comparison of nearly 120 limits of detection (LoD) values reported by labelled and label-free sensing approaches over a wide range of detection techniques and target molecules in serum revealed that labeled techniques achieve 2-3 orders of magnitude better LoDs. Data from experiments where labelled and label-free assays were performed simultaneously using the same assay parameters also confirm that the LoD achieved by labelled techniques is 2 to 3 orders of magnitude better than that by label-free techniques. Furthermore, label-free techniques required significant signal amplification, for e.g. using nanoparticle conjugated secondary antibodies, to achieve LoDs comparable to labelled methods substantially deviating from the original "direct detection" paradigm. This finding has important implications on the practical limits of applying label-free detection methods for molecular diagnosis.

  4. Label-Free Direct Detection of miRNAs with Poly-Silicon Nanowire Biosensors

    PubMed Central

    Gong, Changguo; Qi, Jiming; Xiao, Han; Jiang, Bin; Zhao, Yulan

    2015-01-01

    Background The diagnostic and prognostic value of microRNAs (miRNAs) in a variety of diseases is promising. The novel silicon nanowire (SiNW) biosensors have advantages in molecular detection because of their high sensitivity and fast response. In this study, poly-crystalline silicon nanowire field-effect transistor (poly-SiNW FET) device was developed to achieve specific and ultrasensitive detection of miRNAs without labeling and amplification. Methods The poly-SiNW FET was fabricated by a top–down Complementary Metal Oxide Semiconductor (CMOS) wafer fabrication based technique. Single strand DNA (ssDNA) probe was bind to the surface of the poly-SiNW device which was silanated and aldehyde-modified. By comparing the difference of resistance value before and after ssDNA and miRNA hybridization, poly-SiNW device can be used to detect standard and real miRNA samples. Results Poly-SiNW device with different structures (different line width and different pitch) was applied to detect standard Let-7b sample with a detection limitation of 1 fM. One-base mismatched sequence could be distinguished meanwhile. Furthermore, these poly-SiNW arrays can detect snRNA U6 in total RNA samples extracted from HepG2 cells with a detection limitation of 0.2 μg/mL. In general, structures with pitch showed better results than those without pitch in detection of both Let-7b and snRNA U6. Moreover, structures with smaller pitch showed better detection efficacy. Conclusion Our findings suggest that poly-SiNW arrays could detect standard and real miRNA sample without labeling or amplification. Poly-SiNW biosensor device is promising for miRNA detection. PMID:26709827

  5. Analytical sensitivity of current best-in-class malaria rapid diagnostic tests.

    PubMed

    Jimenez, Alfons; Rees-Channer, Roxanne R; Perera, Rushini; Gamboa, Dionicia; Chiodini, Peter L; González, Iveth J; Mayor, Alfredo; Ding, Xavier C

    2017-03-24

    Rapid diagnostic tests (RDTs) are today the most widely used method for malaria diagnosis and are recommended, alongside microscopy, for the confirmation of suspected cases before the administration of anti-malarial treatment. The diagnostic performance of RDTs, as compared to microscopy or PCR is well described but the actual analytical sensitivity of current best-in-class tests is poorly documented. This value is however a key performance indicator and a benchmark value needed to developed new RDTs of improved sensitivity. Thirteen RDTs detecting either the Plasmodium falciparum histidine rich protein 2 (HRP2) or the plasmodial lactate dehydrogenase (pLDH) antigens were selected from the best performing RDTs according to the WHO-FIND product testing programme. The analytical sensitivity of these products was evaluated using a range of reference materials including P. falciparum and Plasmodium vivax whole parasite samples as well as recombinant proteins. The best performing HRP2-based RDTs could detect all P. falciparum cultured samples at concentrations as low as 0.8 ng/mL of HRP2. The limit of detection of the best performing pLDH-based RDT specifically detecting P. vivax was 25 ng/mL of pLDH. The analytical sensitivity of P. vivax and Pan pLDH-based RDTs appears to vary considerably from product to product, and improvement of the limit-of-detection for P. vivax detecting RDTs is needed to match the performance of HRP2 and Pf pLDH-based RDTs for P. falciparum. Different assays using different reference materials produce different values for antigen concentration in a given specimen, highlighting the need to establish universal reference assays.

  6. Limited diagnostic accuracy of magnetic resonance imaging and clinical tests for detecting partial-thickness tears of the rotator cuff.

    PubMed

    Brockmeyer, Matthias; Schmitt, Cornelia; Haupert, Alexander; Kohn, Dieter; Lorbach, Olaf

    2017-12-01

    The reliable diagnosis of partial-thickness tears of the rotator cuff is still elusive in clinical practise. Therefore, the purpose of the study was to determine the diagnostic accuracy of MR imaging and clinical tests for detecting partial-thickness tears of the rotator cuff as well as the combination of these parameters. 334 consecutive shoulder arthroscopies for rotator cuff pathologies performed during the time period between 2010 and 2012 were analyzed retrospectively for the findings of common clinical signs for rotator cuff lesions and preoperative MR imaging. These were compared with the intraoperative arthroscopic findings as "gold standard". The reports of the MR imaging were evaluated with regard to the integrity of the rotator cuff. The Ellman Classification was used to define partial-thickness tears of the rotator cuff in accordance with the arthroscopic findings. Descriptive statistics, sensitivity, specificity, positive and negative predictive value were calculated. MR imaging showed 80 partial-thickness and 70 full-thickness tears of the rotator cuff. The arthroscopic examination confirmed 64 partial-thickness tears of which 52 needed debridement or refixation of the rotator cuff. Sensitivity for MR imaging to identify partial-thickness tears was 51.6%, specificity 77.2%, positive predictive value 41.3% and negative predictive value 83.7%. For the Jobe-test, sensitivity was 64.1%, specificity 43.2%, positive predictive value 25.9% and negative predictive value 79.5%. Sensitivity for the Impingement-sign was 76.7%, specificity 46.6%, positive predictive value 30.8% and negative predictive value 86.5%. For the combination of MR imaging, Jobe-test and Impingement-sign sensitivity was 46.9%, specificity 85.4%, positive predictive value 50% and negative predictive value 83.8%. The diagnostic accuracy of MR imaging and clinical tests (Jobe-test and Impingement-sign) alone is limited for detecting partial-thickness tears of the rotator cuff. Additionally, the combination of MR imaging and clinical tests does not improve diagnostic accuracy. Level II, Diagnostic study.

  7. Nanobody medicated immunoassay for ultrasensitive detection of cancer biomarker alpha-fetoprotein.

    PubMed

    Chen, Jing; He, Qing-hua; Xu, Yang; Fu, Jin-heng; Li, Yan-ping; Tu, Zhui; Wang, Dan; Shu, Mei; Qiu, Yu-lou; Yang, Hong-wei; Liu, Yuan-yuan

    2016-01-15

    Immunoassay for cancer biomarkers plays an important role in cancer prevention and early diagnosis. To the development of immunoassay, the quality and stability of applied antibody is one of the key points to obtain reliability and high sensitivity for immunoassay. The main purpose of this study was to develop a novel immunoassay for ultrasensitive detection of cancer biomarker alpha-fetoprotein (AFP) based on nanobody against AFP. Two nanobodies which bind to AFP were selected from a phage display nanobody library by biopanning strategy. The prepared nanobodies are clonable, thermally stable and applied in both sandwich enzyme linked immunoassay (ELISA) and immuno-PCR assay for ultrasensitive detection of AFP. The limit detection of sandwich ELISA setup with optimized nanobodies was 0.48ng mL(-1), and the half of saturation concentration (SC50) value was 6.68±0.56ng mL(-1). These nanobodies were also used to develop an immuno-PCR assay for ultrasensitive detection of AFP, its limit detection values was 0.005ng mL(-1), and the linear range was 0.01-10,000ng mL(-1). These established immunoassays based on nanobodies were highly specific to AFP and with negligible cross reactivity with other tested caner biomarkers. Furthermore, this novel concept of nanobodies mediated immunoassay may provide potential applications in a general method for the ultrasensitive detection of various cancer biomarkers. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Detection of tire tread particles using laser-induced breakdown spectroscopy

    NASA Astrophysics Data System (ADS)

    Prochazka, David; Bilík, Martin; Prochazková, Petra; Klus, Jakub; Pořízka, Pavel; Novotný, Jan; Novotný, Karel; Ticová, Barbora; Bradáč, Albert; Semela, Marek; Kaiser, Jozef

    2015-06-01

    The objective of this paper is a study of the potential of laser induced breakdown spectroscopy (LIBS) for detection of tire tread particles. Tire tread particles may represent pollutants; simultaneously, it is potentially possible to exploit detection of tire tread particles for identification of optically imperceptible braking tracks at locations of road accidents. The paper describes the general composition of tire treads and selection of an element suitable for detection using the LIBS method. Subsequently, the applicable spectral line is selected considering interferences with lines of elements that might be present together with the detected particles, and optimization of measurement parameters such as incident laser energy, gate delay and gate width is performed. In order to eliminate the matrix effect, measurements were performed using 4 types of tires manufactured by 3 different producers. An adhesive tape was used as a sample carrier. The most suitable adhesive tape was selected from 5 commonly available tapes, on the basis of their respective LIBS spectra. Calibration standards, i.e. an adhesive tape with different area content of tire tread particles, were prepared for the selected tire. A calibration line was created on the basis of the aforementioned calibration standards. The linear section of this line was used for determination of the detection limit value applicable to the selected tire. Considering the insignificant influence of matrix of various types of tires, it is possible to make a simple recalculation of the detection limit value on the basis of zinc content in a specific tire.

  9. Correlations between serum trypsinogen-2 and pancreatic cancer.

    PubMed

    Cao, Jianbiao; Xia, Changhong; Cui, Tingting; Guo, Hanbin; Li, Haoran; Ren, Yongqiang; Wang, Shuai

    2015-01-01

    To investigate associations be- tween serum trypsinogen-2, pancreatitis and pancreatic cancer (PC) and determine cutoff values for PC diagnosis. We recruited 88 patients from Internal Medicine/Surgical Departments of General Military Hospital of Beijing PLA between 12/2009 and 6/2010. Serum samples were collected preoperatively from 23 PC patients, 30 pancreatitis patients and 35 healthy controls. Enzyme-linked immunosorbent assay was used to detect trypsinogen-2 semiquantitatively. Serum trypsinogen-2 levels of PC and pancreatitis patients were significantly higher than those of controls (51.2 ± 80.3, 107.7 ± 98.1 vs. 1.0 ± 0.5, p = 0.03, p < 0.001) and significantly higher in pancreatitis vs. PC patients (107.7 ± 98.1 vs. 51.2 ± 80.3, p = 0.01). Higher Balthazar CT grades correlated with higher trypsinogen-2 in pancreatitis group. ROC curves for trypsinogen-2 revealed optimal cutoff value 1.8 as lower PC detection limit with 95.7% sensitivity and 91.4% specificity, and optimal cutoff value 19.9 for upper PC detection limit with 87.0% sensitivity and 97.1% specificity. Trypsinogen-2 levels correlated with pancreatic injury level. An AUC of 0.73 (95% Cl: 0.59-0.84, p = 0.002) distinguished PC from pancreatitis. Serum trypsinogen-2 is associated with PC and pancreatitis. Levels between 1.8 μg/L and 19.9 μg/L strongly suggest PC. Detection of serum trypsinogen-2 may provide simple, sensitive, specific non-invasive initial screening for early PC diagnosis.

  10. Track Score Processing of Multiple Dissimilar Sensors

    DTIC Science & Technology

    2007-06-01

    sensors ( infrared and light detection and ranging system) and one radio frenquency sensor (radar). The signal to noise ratio and design considerations...categorized as Johnson noise , shot noise , generation-recombination noise , temperature noise , microphonic noise , 1/f noise , and finally electronic...of 2.1 µm. The values of detectivity in this figure were derived from an analysis of commercial detectors , under background- limited conditions, at

  11. Diagnostic value of highly-sensitive chimerism analysis after allogeneic stem cell transplantation.

    PubMed

    Sellmann, Lea; Rabe, Kim; Bünting, Ivonne; Dammann, Elke; Göhring, Gudrun; Ganser, Arnold; Stadler, Michael; Weissinger, Eva M; Hambach, Lothar

    2018-05-02

    Conventional analysis of host chimerism (HC) frequently fails to detect relapse before its clinical manifestation in patients with hematological malignancies after allogeneic stem cell transplantation (allo-SCT). Quantitative PCR (qPCR)-based highly-sensitive chimerism analysis extends the detection limit of conventional (short tandem repeats-based) chimerism analysis from 1 to 0.01% host cells in whole blood. To date, the diagnostic value of highly-sensitive chimerism analysis is hardly defined. Here, we applied qPCR-based chimerism analysis to 901 blood samples of 71 out-patients with hematological malignancies after allo-SCT. Receiver operating characteristics (ROC) curves were calculated for absolute HC values and for the increments of HC before relapse. Using the best cut-offs, relapse was detected with sensitivities of 74 or 85% and specificities of 69 or 75%, respectively. Positive predictive values (PPVs) were only 12 or 18%, but the respective negative predictive values were 98 or 99%. Relapse was detected median 38 or 45 days prior to clinical diagnosis, respectively. Considering also durations of steadily increasing HC of more than 28 days improved PPVs to more than 28 or 59%, respectively. Overall, highly-sensitive chimerism analysis excludes relapses with high certainty and predicts relapses with high sensitivity and specificity more than a month prior to clinical diagnosis.

  12. Limitation of the Predominant-Period Estimator for Earthquake Early Warning and the Initial Rupture of Earthquakes

    NASA Astrophysics Data System (ADS)

    Yamada, T.; Ide, S.

    2007-12-01

    Earthquake early warning is an important and challenging issue for the reduction of the seismic damage, especially for the mitigation of human suffering. One of the most important problems in earthquake early warning systems is how immediately we can estimate the final size of an earthquake after we observe the ground motion. It is relevant to the problem whether the initial rupture of an earthquake has some information associated with its final size. Nakamura (1988) developed the Urgent Earthquake Detection and Alarm System (UrEDAS). It calculates the predominant period of the P wave (τp) and estimates the magnitude of an earthquake immediately after the P wave arrival from the value of τpmax, or the maximum value of τp. The similar approach has been adapted by other earthquake alarm systems (e.g., Allen and Kanamori (2003)). To investigate the characteristic of the parameter τp and the effect of the length of the time window (TW) in the τpmax calculation, we analyze the high-frequency recordings of earthquakes at very close distances in the Mponeng mine in South Africa. We find that values of τpmax have upper and lower limits. For larger earthquakes whose source durations are longer than TW, the values of τpmax have an upper limit which depends on TW. On the other hand, the values for smaller earthquakes have a lower limit which is proportional to the sampling interval. For intermediate earthquakes, the values of τpmax are close to their typical source durations. These two limits and the slope for intermediate earthquakes yield an artificial final size dependence of τpmax in a wide size range. The parameter τpmax is useful for detecting large earthquakes and broadcasting earthquake early warnings. However, its dependence on the final size of earthquakes does not suggest that the earthquake rupture is deterministic. This is because τpmax does not always have a direct relation to the physical quantities of an earthquake.

  13. Development of an enzyme-linked immunosorbent assay for the detection of dicamba.

    PubMed

    Clegg, B S; Stephenson, G R; Hall, J C

    2001-05-01

    A competitive indirect enzyme-linked immunosorbent assay (CI-ELISA) was developed to quantitate the herbicide dicamba (3,6-dichloro-2-methoxybenzoic acid) in water. The CI-ELISA has a detection limit of 2.3 microg L(-1) and a linear working range of 10--10000 microg L(-1) with an IC(50) value of 195 microg L(-1). The dicamba polyclonal antisera did not cross-react with a number of other herbicides tested but did cross-react with a dicamba metabolite, 5-hydroxydicamba, and structurally related chlorobenzoic acids. The assay was used to estimate quantitatively dicamba concentrations in water samples. Water samples were analyzed directly, and no sample preparation was required. To improve detection limits, a C(18) (reversed phase) column concentration step was devised prior to analysis, and the detection limits were increased by at least by 10-fold. After the sample preconcentration, the detection limit, IC(50), and linear working range were 0.23, 19.5, and 5-200 microg L(-1), respectively. The CI-ELISA estimations in water correlated well with those from gas chromatography-mass spectrometry (GC-MS) analysis (r(2) = 0.9991). This assay contributes to reducing laboratory costs associated with the conventional GC-MS residue analysis techniques for the quantitation of dicamba in water.

  14. Laser-based detection of chemical contraband

    NASA Astrophysics Data System (ADS)

    Clemmer, Robert G.; Kelly, James F.; Martin, Steven W.; Mong, Gary M.; Sharpe, Steven W.

    1997-02-01

    The goal of our work is tow fold; 1) develop a portable and rapid laser based air sampler for detection of specific chemical contraband and 2) compile a spectral data base in both the near- and mid-IR of sufficiently high quality to be useful for gas phase spectroscopic identification of chemical contraband. During the synthesis or 'cooking' of many illicit chemical substances, relatively high concentrations of volatile solvents, chemical precursors and byproducts are unavoidably released to the atmosphere. In some instances, the final product may have sufficient vapor pressure to be detectable in the surrounding air. The detection of a single high-value effluent or the simultaneous detection of two or more low-value effluents can be used as reliable indicators of a nearby clandestine cooking operation. The designation of high- versus low-value effluent reflects both the commercial availability and legitimate usage of a specific chemical. This paper will describe PNNL's progress and efforts towards the development of a portable laser based air sampling system for the detection of clandestine manufacturing of methamphetamine. Although our current efforts ar focused on methamphetamine, we see no fundamental limitations on detection of other forms of chemical contraband manufacturing. This also includes the synthesis of certain classes of chemical weapons that have recently been deployed by terrorist groups.

  15. Derivative spectrophotometric analysis of benzophenone (as an impurity) in phenytoin

    PubMed Central

    2011-01-01

    Three simple and rapid spectrophotometric methods were developed for detection and trace determination of benzophenone (the main impurity) in phenytoin bulk powder and pharmaceutical formulations. The first method, zero-crossing first derivative spectrophotometry, depends on measuring the first derivative trough values at 257.6 nm for benzophenone. The second method, zero-crossing third derivative spectrophotometry, depends on measuring the third derivative peak values at 263.2 nm. The third method, ratio first derivative spectrophotometry, depends on measuring the peak amplitudes of the first derivative of the ratio spectra (the spectra of benzophenone divided by the spectrum of 5.0 μg/mL phenytoin solution) at 272 nm. The calibration graphs were linear over the range of 1-10 μg/mL. The detection limits of the first and the third derivative methods were found to be 0.04 μg/mL and 0.11 μg/mL and the quantitation limits were 0.13 μg/mL and 0.34 μg/mL, respectively, while for the ratio derivative method, the detection limit was 0.06 μg/mL and the quantitation limit was 0.18 μg/mL. The proposed methods were applied successfully to the assay of the studied drug in phenytoin bulk powder and certain pharmaceutical preparations. The results were statistically compared to those obtained using a polarographic method and were found to be in good agreement. PMID:22152156

  16. Detection method of flexion relaxation phenomenon based on wavelets for patients with low back pain

    NASA Astrophysics Data System (ADS)

    Nougarou, François; Massicotte, Daniel; Descarreaux, Martin

    2012-12-01

    The flexion relaxation phenomenon (FRP) can be defined as a reduction or silence of myoelectric activity of the lumbar erector spinae muscle during full trunk flexion. It is typically absent in patients with chronic low back pain (LBP). Before any broad clinical utilization of this neuromuscular response can be made, effective, standardized, and accurate methods of identifying FRP limits are needed. However, this phenomenon is clearly more difficult to detect for LBP patients than for healthy patients. The main goal of this study is to develop an automated method based on wavelet transformation that would improve time point limits detection of surface electromyography signals of the FRP in case of LBP patients. Conventional visual identification and proposed automated methods of time point limits detection of relaxation phase were compared on experimental data using criteria of accuracy and repeatability based on physiological properties. The evaluation demonstrates that the use of wavelet transform (WT) yields better results than methods without wavelet decomposition. Furthermore, methods based on wavelet per packet transform are more effective than algorithms employing discrete WT. Compared to visual detection, in addition to demonstrating an obvious saving of time, the use of wavelet per packet transform improves the accuracy and repeatability in the detection of the FRP limits. These results clearly highlight the value of the proposed technique in identifying onset and offset of the flexion relaxation response in LBP subjects.

  17. Detection of HIV-1 p24 at Attomole Level by Ultrasensitive ELISA with Thio-NAD Cycling

    PubMed Central

    Nakatsuma, Akira; Kaneda, Mugiho; Kodama, Hiromi; Morikawa, Mika; Watabe, Satoshi; Nakaishi, Kazunari; Yamashita, Masakane; Yoshimura, Teruki; Miura, Toshiaki; Ninomiya, Masaki; Ito, Etsuro

    2015-01-01

    To reduce the window period between HIV-1 infection and the ability to diagnose it, a fourth-generation immunoassay including the detection of HIV-1 p24 antigen has been developed. However, because the commercially available systems for this assay use special, high-cost instruments to measure, for example, chemiluminescence, it is performed only by diagnostics companies and hub hospitals. To overcome this limitation, we applied an ultrasensitive ELISA coupled with a thio-NAD cycling, which is based on a usual enzyme immunoassay without special instruments, to detect HIV-1 p24. The p24 detection limit by our ultrasensitive ELISA was 0.0065 IU/assay (i.e., ca. 10-18 moles/assay). Because HIV-1 p24 antigen is thought to be present in the virion in much greater numbers than viral RNA copies, the value of 10-18 moles of the p24/assay corresponds to ca. 103 copies of the HIV-1 RNA/assay. That is, our ultrasensitive ELISA is chasing the detection limit (102 copies/assay) obtained by PCR-based nucleic acid testing (NAT) with a margin of only one different order. Further, the detection limit by our ultrasensitive ELISA is less than that mandated for a CE-marked HIV antigen/antibody assay. An additional recovery test using blood supported the reliability of our ultrasensitive ELISA. PMID:26098695

  18. Applying ISO 11929:2010 Standard to detection limit calculation in least-squares based multi-nuclide gamma-ray spectrum evaluation

    NASA Astrophysics Data System (ADS)

    Kanisch, G.

    2017-05-01

    The concepts of ISO 11929 (2010) are applied to evaluation of radionuclide activities from more complex multi-nuclide gamma-ray spectra. From net peak areas estimated by peak fitting, activities and their standard uncertainties are calculated by weighted linear least-squares method with an additional step, where uncertainties of the design matrix elements are taken into account. A numerical treatment of the standard's uncertainty function, based on ISO 11929 Annex C.5, leads to a procedure for deriving decision threshold and detection limit values. The methods shown allow resolving interferences between radionuclide activities also in case of calculating detection limits where they can improve the latter by including more than one gamma line per radionuclide. The co"mmon single nuclide weighted mean is extended to an interference-corrected (generalized) weighted mean, which, combined with the least-squares method, allows faster detection limit calculations. In addition, a new grouped uncertainty budget was inferred, which for each radionuclide gives uncertainty budgets from seven main variables, such as net count rates, peak efficiencies, gamma emission intensities and others; grouping refers to summation over lists of peaks per radionuclide.

  19. Comparison of detection limit in fiber-based conventional, amplified, and gain-clamped cavity ring-down techniques

    NASA Astrophysics Data System (ADS)

    Sharma, K.; Abdul Khudus, M. I. M.; Alam, S. U.; Bhattacharya, S.; Venkitesh, D.; Brambilla, G.

    2018-01-01

    Relative performance and detection limit of conventional, amplified, and gain-clamped cavity ring-down techniques (CRDT) in all-fiber configurations are compared experimentally for the first time. Refractive index measurement using evanescent field in tapered fibers is used as a benchmark for the comparison. The systematic optimization of a nested-loop configuration in gain-clamped CRDT is also discussed, which is crucial for achieving a constant gain in a CRDT experiment. It is found that even though conventional CRDT has the lowest standard error in ring-down time (Δτ), the value of ring-down time (τ) is very small, thus leading to poor detection limit. Amplified CRDT provides an improvement in τ, albeit with two orders of magnitude higher Δτ due to amplifier noise. The nested-loop configuration in gain-clamped CRDT helps in reducing Δτ by an order of magnitude as compared to amplified CRDT whilst retaining the improvement in τ. A detection limit of 1 . 03 × 10-4 RIU at refractive index of 1.322 with a 3 mm long and 4.5 μm diameter tapered fiber is demonstrated with the gain-clamped CRDT.

  20. Association of incidental emphysema with annual lung function decline and future development of airflow limitation

    PubMed Central

    Koo, Hyeon-Kyoung; Jin, Kwang Nam; Kim, Deog Kyeom; Chung, Hee Soon; Lee, Chang-Hoon

    2016-01-01

    Objectives Emphysema is one of the prognostic factors for rapid lung function decline in patients with COPD, but the impact of incidentally detected emphysema on population without spirometric abnormalities has not been evaluated. This study aimed to determine whether emphysema detected upon computed tomography (CT) screening would accelerate the rate of lung function decline and influence the possibility of future development of airflow limitation in a population without spirometric abnormalities. Materials and methods Subjects who participated in a routine screening for health checkup and follow-up pulmonary function tests for at least 3 years between 2004 and 2010 were retrospectively enrolled. The percentage of low-attenuation area below −950 Hounsfield units (%LAA−950) was calculated automatically. A calculated value of %LAA−950 that exceeded 10% was defined as emphysema. Adjusted annual lung function decline was analyzed using random-slope, random-intercept mixed linear regression models. Results A total of 628 healthy subjects within the normal range of spriometric values were included. Multivariable analysis showed that the emphysema group exhibited a faster decline in forced vital capacity (−33.9 versus −18.8 mL/year; P=0.02). Emphysema was not associated with the development of airflow limitation during follow-up. Conclusion Incidental emphysema quantified using CT scan was significantly associated with a more rapid decline in forced vital capacity in the population with normative spirometric values. However, an association between emphysema and future development of airflow limitation was not observed. PMID:26893550

  1. Simultaneous determination of niacin and pyridoxine at trace levels by using diode array high-performance liquid chromatography and liquid chromatography with quadrupole time-of-flight tandem mass spectrometry.

    PubMed

    Sel, Sabriye; Öztürk Er, Elif; Bakırdere, Sezgin

    2017-12-01

    A highly sensitive and simple diode-array high-performance liquid chromatography and liquid chromatography with quadrupole time-of-flight tandem mass spectrometry method was developed for the simultaneous determination of niacin and pyridoxine in pharmaceutical drugs, tap water, and wastewater samples. To determine the in vivo behavior of niacin and pyridoxine, analytes were subjected to simulated gastric conditions. The calibration plots of the diode-array high-performance liquid chromatography and liquid chromatography with quadrupole time-of-flight tandem mass spectrometry method showed good linearity over a wide concentration range with close to 1.0 correlation coefficients for both analytes. The limit of detection/limit of quantitation values for liquid chromatography quadrupole time-of-flight tandem mass spectrometry analysis were 1.98/6.59 and 1.3/4.4 μg/L for niacin and pyridoxine, respectively, while limit of detection/limit of quantitation values for niacin and pyridoxine in high-performance liquid chromatography analysis were 3.7/12.3 and 5.7/18.9 μg/L, respectively. Recovery studies were also performed to show the applicability of the developed methods, and percentage recovery values were found to be 90-105% in tap water and 94-97% in wastewater for both analytes. The method was also successfully applied for the qualitative and quantitative determination of niacin and pyridoxine in drug samples. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Comparison of two microextraction methods based on solidification of floating organic droplet for the determination of multiclass analytes in river water samples by liquid chromatography tandem mass spectrometry using Central Composite Design.

    PubMed

    Asati, Ankita; Satyanarayana, G N V; Patel, Devendra K

    2017-09-01

    Two low density organic solvents based liquid-liquid microextraction methods, namely Vortex assisted liquid-liquid microextraction based on solidification of floating organic droplet (VALLME-SFO) and Dispersive liquid-liquid microextraction based on solidification of floating organic droplet(DLLME-SFO) have been compared for the determination of multiclass analytes (pesticides, plasticizers, pharmaceuticals and personal care products) in river water samples by using liquid chromatography tandem mass spectrometry (LC-MS/MS). The effect of various experimental parameters on the efficiency of the two methods and their optimum values were studied with the aid of Central Composite Design (CCD) and Response Surface Methodology(RSM). Under optimal conditions, VALLME-SFO was validated in terms of limit of detection, limit of quantification, dynamic linearity range, determination of coefficient, enrichment factor and extraction recovery for which the respective values were (0.011-0.219ngmL -1 ), (0.035-0.723ngmL -1 ), (0.050-0.500ngmL -1 ), (R 2 =0.992-0.999), (40-56), (80-106%). However, when the DLLME-SFO method was validated under optimal conditions, the range of values of limit of detection, limit of quantification, dynamic linearity range, determination of coefficient, enrichment factor and extraction recovery were (0.025-0.377ngmL -1 ), (0.083-1.256ngmL -1 ), (0.100-1.000ngmL -1 ), (R 2 =0.990-0.999), (35-49), (69-98%) respectively. Interday and intraday precisions were calculated as percent relative standard deviation (%RSD) and the values were ≤15% for VALLME-SFO and DLLME-SFO methods. Both methods were successfully applied for determining multiclass analytes in river water samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. DETECTION AND DISINFECTION OF PATHOGENS IN STORM- GENERATED FLOWS

    EPA Science Inventory

    The disease-producing potential of recreational waters is currently estimated through the use of certain bacterial indicators that are believed to be positively correlated with the presence of fecal contamination. In general, these indicators and their recommended limiting values...

  4. Diagnosis of catheter-related bloodstream infections among pediatric oncology patients lacking a peripheral culture, using differential time to detection.

    PubMed

    Gaur, Aditya H; Flynn, Patricia M; Heine, Daniel J; Giannini, Mary Anne; Shenep, Jerry L; Hayden, Randall T

    2005-05-01

    Current methods for in situ diagnosis of catheter-related bloodstream infections require concurrent collection of central venous catheter (CVC) and peripheral vein (PV) blood cultures. Both the pain and inconvenience of PV cultures are undesirable. A prospective study was conducted (August 2002 to March 2004) to assess the accuracy of diagnosing catheter-related bloodstream infections based on the difference in time to detection of blood cultures drawn concurrently from 2 lumens of a multilumen CVC. This difference in time to detection between 2 lumens was compared with results of the standard criterion with paired CVC and PV blood cultures. Twenty-one infectious episodes were categorized as catheter-related bloodstream infections and 38 as non-catheter-related bloodstream infections. With a cutoff in difference in time to detection between 2 lumens of > or =180 minutes, the sensitivity of this test to diagnose a catheter-related bloodstream infection was 61% (95% confidence interval, 39-80%) and the specificity was 94% (95% confidence interval, 82-99%). In 4 of 7 episodes with false-negative results, the colony counts in cultures from both lumens were >400 colony-forming units/mL (maximal value reported), indicating the limitation of this method when both lumens of the catheter are colonized. With the pretest probability of catheter-related bloodstream infections ranging from 28% to 54%, the positive predictive value of a difference in time to detection between 2 lumens of > or =180 minutes for diagnosis of catheter-related bloodstream infections ranged from 81% to 93% and the negative predictive value ranged from 67% to 86%. Within the context of its limitations, this novel method provides an alternative for diagnosing catheter-related bloodstream infections among patients with a CVC, without PV cultures.

  5. A visual assay and spectrophotometric determination of LLM-105 explosive using detection of gold nanoparticle aggregation at two pH values.

    PubMed

    He, Yi; Cheng, Yang

    2016-08-01

    We report a simple, rapid, and sensitive assay for visual and spectrophotometric detection of the 2,6-diamino-3,5-dinitropyrazine-1-oxide (LLM-105) explosive. The assay is based on different interactions between LLM-105 and gold nanoparticle (AuNP) dispersions at two pH values, leading to the formation of dispersed or aggregated AuNPs. Two AuNP dispersions at two pH values were applied to recognize and detect LLM-105 instead of traditional AuNP dispersion under an aptotic pH to improve the anti-interference ability. The developed assay showed excellent sensitivity with a detection limit of 3 ng/mL, and the presence of as low as 0.2 μg/mL LLM-105 can be directly detected with the bare eye. This sensitivity is about six orders of magnitude higher than that of the reported traditional assays. Additionally, the assay exhibited good selectivity toward LLM-105 over other explosives, sulfur-containing compounds, and amines. Graphical abstract A simple, sensitive, and selective assay for LLM-105 was developed based on the pH-dependent interaction between the LLM-105 explosive and gold nanoparticle dispersion.

  6. Evaluation of the potential of laser-induced breakdown spectroscopy for detection of trace element in liquid.

    PubMed

    Yueh, Fang-Yu; Sharma, Ramesh C; Singh, Jagdish P; Zhang, Hansheng; Spencer, William A

    2002-11-01

    The analytical figure of merit of the potential of laser-induced breakdown spectroscopy (LIBS) has been evaluated for detection of trace element in liquid. LIBS data of Mg, Cr, Mn, and Re were studied. Various optical geometries, which produce the laser spark in and at the liquid sample, were tested. The calibration curves for Mg, Cr, Mn, and Re were obtained at the optimized experimental conditions with bulk liquid and in liquid jet. It was found that measurements using a liquid jet provide better detection limits than bulk liquid measurements. The limits of detection (LOD) of Mg, Cr, Mn, and Re in the present liquid jet measurement are found to be 0.1, 0.4, 0.7, and 8 ppm, respectively. The LOD of Mg using Mg 279.55 nm was compared with the values found in other liquid work.

  7. Receptor binding assay for paralytic shellfish poisoning toxins: optimization and interlaboratory comparison.

    PubMed

    Ruberu, Shryamalie R; Liu, Yun-Gang; Wong, Carolyn T; Perera, S Kusum; Langlois, Gregg W; Doucette, Gregory J; Powell, Christine L

    2003-01-01

    A receptor binding assay (RBA) for detection of paralytic shellfish poisoning (PSP) toxins was formatted for use in a high throughput detection system using microplate scintillation counting. The RBA technology was transferred from the National Ocean Service, which uses a Wallac TriLux 1450 MicroBeta microplate scintillation counter, to the California Department of Health Services, which uses a Packard TopCount scintillation counter. Due to differences in the detector arrangement between these 2 counters, markedly different counting efficiencies were exhibited, requiring optimization of the RBA protocol for the TopCount instrument. Precision, accuracy, and sensitivity [limit of detection = 0.2 microg saxitoxin (STX) equiv/100 g shellfish tissue] of the modified protocol were equivalent to those of the original protocol. The RBA robustness and adaptability were demonstrated by an interlaboratory study, in which STX concentrations in shellfish generated by the TopCount were consistent with MicroBeta-derived values. Comparison of STX reference standards obtained from the U.S. Food and Drug Administration and the National Research Council, Canada, showed no observable differences. This study confirms the RBA's value as a rapid, high throughput screen prior to testing by the conventional mouse bioassay (MBA) and its suitability for providing an early warning of increasing PSP toxicity when toxin levels are below the MBA limit of detection.

  8. Tracking Dissolved Methane Concentrations near Active Seeps and Gas Hydrates: Sea of Japan.

    NASA Astrophysics Data System (ADS)

    Snyder, G. T.; Aoki, S.; Matsumoto, R.; Tomaru, H.; Owari, S.; Nakajima, R.; Doolittle, D. F.; Brant, B.

    2015-12-01

    A number of regions in the Sea of Japan are known for active gas venting and for gas hydrate exposures on the sea floor. In this investigation we employed several gas sensors mounted on a ROV in order to determine the concentrations of dissolved methane in the water near these sites. Methane concentrations were determined during two-second intervals throughout each ROV deployment during the cruise. The methane sensor deployments were coupled with seawater sampling using Niskin bottles. Dissolved gas concentrations were later measured using gas chromatography in order to compare with the sensor results taken at the same time. The observed maximum dissolved methane concentrations were much lower than saturation values, even when the ROV manipulators were in contact with gas hydrate. Nonetheless, dissolved concentrations did reach several thousands of nmol/L near gas hydrate exposures and gas bubbles, more than two orders of magnitude over the instrumental detection limits. Most of the sensors tested were able to detect dissolved methane concentrations as low as 10 nmol/L which permitted detection when the ROV approached methane plume sites, even from several tens of meters above the sea floor. Despite the low detection limits, the methane sensors showed variable response times when returning to low-background seawater (~5nM). For some of the sensors, the response time necessary to return to background values occurred in a matter of minutes, while for others it took several hours. Response time, as well as detection limit, should be an important consideration when selecting methane sensors for ROV or AUV investigations. This research was made possible, in part, through funding provided by the Japanese Ministry of Economy, Trade and Industry (METI).

  9. Analysis of volatile organic compounds from illicit cocaine samples

    NASA Astrophysics Data System (ADS)

    Robins, W. H.; Wright, Bob W.

    1994-10-01

    Detection of illicit cocaine hydrochloride shipments can be improved if there is a greater understanding of the identity and quantity of volatile compounds present. This study provides preliminary data concerning the volatile organic compounds detected in a limited set of cocaine hydrochloride samples. In all cases, cocaine was one of the major volatile compounds detected. Other tropeines were detected in almost all samples. Low concentrations of compounds which may be residues of processing solvents were observed in some samples. The equilibrium emissivity of cocaine from cocaine hydrochloride was investigated and a value of 83 parts-per-trillion was determined.

  10. Electrochemical detection of p-ethylguaiacol, a fungi infected fruit volatile using metal oxide nanoparticles.

    PubMed

    Fang, Yi; Umasankar, Yogeswaran; Ramasamy, Ramaraja P

    2014-08-07

    Nanoparticles of TiO(2) or SnO(2) on screen-printed carbon (SP) electrodes have been developed for evaluating their potential application in the electrochemical sensing of volatiles in fruits and plants. These metal oxide nanoparticle-modified electrodes possess high sensitivity and low detection limit for the detection of p-ethylguaiacol, a fingerprint compound present in the volatile signature of fruits and plants infected with a pathogenic fungus Phytophthora cactorum. The electroanalytical data obtained using cyclic voltammetry and differential pulse voltammetry showed that both SnO(2) and TiO(2) exhibited high sensitivity (174-188 μA cm(-2) mM(-1)) and low detection limits (35-62 nM) for p-ethylguaiacol detection. The amperometric detection was highly repeatable with RSD values ranging from 2.48 to 4.85%. The interference studies show that other common plant volatiles do not interfere in the amperometric detection signal of p-ethylguaiacol. The results demonstrate that metal oxides are a reasonable alternative to expensive electrode materials such as gold or platinum for amperometric sensor applications.

  11. A comparative study evaluating the efficacy of IS_MAP04 with IS900 and IS_MAP02 as a new diagnostic target for the detection of Mycobacterium avium subspecies paratuberculosis from bovine faeces.

    PubMed

    de Kruijf, Marcel; Govender, Rodney; Yearsley, Dermot; Coffey, Aidan; O'Mahony, Jim

    2017-05-01

    The aim of this study was to investigate the efficacy of IS_MAP04 as a potential new diagnostic quantitative PCR (qPCR) target for the detection of Mycobacterium avium subspecies paratuberculosis from bovine faeces. IS_MAP04 primers were designed and tested negative against non-MAP strains. The detection limit of IS_MAP04 qPCR was evaluated on different MAP K-10 DNA concentrations and on faecal samples spiked with different MAP K-10 cell dilutions. A collection of 106 faecal samples was analysed and the efficacy of IS_MAP04 was statistically compared with IS900 and IS_MAP02. The detection limits observed for IS_MAP04 and IS900 on MAP DNA was 34 fg and 3.4 fg respectively. The detection limit of MAP from inoculated faecal samples was 10 2 CFU/g for both IS_MAP04 and IS900 targets and a detection limit of 10 2 CFU/g was also achieved with a TaqMan qPCR targeting IS_MAP04. The efficacy of IS_MAP04 to detect positive MAP faecal samples was 83.0% compared to 85.8% and 83.9% for IS900 and IS_MAP02 respectively. Strong kappa agreements were observed between IS_MAP04 and IS900 (κ=0.892) and between IS_MAP04 and IS_MAP02 (κ=0.897). As a new molecular target, IS_MAP04 showed that the detection limit was comparable to IS900 to detect MAP from inoculated faecal material. The MAP detection efficacy of IS_MAP04 from naturally infected faecal samples proved to be relatively comparable to IS_MAP02, but yielded efficacy results slightly less than IS900. Moreover, IS_MAP04 could be of significant value when used in duplex or multiplex qPCR assays. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Limited copy number - high resolution melting (LCN-HRM) enables the detection and identification by sequencing of low level mutations in cancer biopsies

    PubMed Central

    Do, Hongdo; Dobrovic, Alexander

    2009-01-01

    Background Mutation detection in clinical tumour samples is challenging when the proportion of tumour cells, and thus mutant alleles, is low. The limited sensitivity of conventional sequencing necessitates the adoption of more sensitive approaches. High resolution melting (HRM) is more sensitive than sequencing but identification of the mutation is desirable, particularly when it is important to discriminate false positives due to PCR errors or template degradation from true mutations. We thus developed limited copy number - high resolution melting (LCN-HRM) which applies limiting dilution to HRM. Multiple replicate reactions with a limited number of target sequences per reaction allow low level mutations to be detected. The dilutions used (based on Ct values) are chosen such that mutations, if present, can be detected by the direct sequencing of amplicons with aberrant melting patterns. Results Using cell lines heterozygous for mutations, we found that the mutations were not readily detected when they comprised 10% of total alleles (20% tumour cells) by sequencing, whereas they were readily detectable at 5% total alleles by standard HRM. LCN-HRM allowed these mutations to be identified by direct sequencing of those positive reactions. LCN-HRM was then used to review formalin-fixed paraffin-embedded (FFPE) clinical samples showing discordant findings between sequencing and HRM for KRAS exon 2 and EGFR exons 19 and 21. Both true mutations present at low levels and sequence changes due to artefacts were detected by LCN-HRM. The use of high fidelity polymerases showed that the majority of the artefacts were derived from the damaged template rather than replication errors during amplification. Conclusion LCN-HRM bridges the sensitivity gap between HRM and sequencing and is effective in distinguishing between artefacts and true mutations. PMID:19811662

  13. Limited copy number-high resolution melting (LCN-HRM) enables the detection and identification by sequencing of low level mutations in cancer biopsies.

    PubMed

    Do, Hongdo; Dobrovic, Alexander

    2009-10-08

    Mutation detection in clinical tumour samples is challenging when the proportion of tumour cells, and thus mutant alleles, is low. The limited sensitivity of conventional sequencing necessitates the adoption of more sensitive approaches. High resolution melting (HRM) is more sensitive than sequencing but identification of the mutation is desirable, particularly when it is important to discriminate false positives due to PCR errors or template degradation from true mutations.We thus developed limited copy number - high resolution melting (LCN-HRM) which applies limiting dilution to HRM. Multiple replicate reactions with a limited number of target sequences per reaction allow low level mutations to be detected. The dilutions used (based on Ct values) are chosen such that mutations, if present, can be detected by the direct sequencing of amplicons with aberrant melting patterns. Using cell lines heterozygous for mutations, we found that the mutations were not readily detected when they comprised 10% of total alleles (20% tumour cells) by sequencing, whereas they were readily detectable at 5% total alleles by standard HRM. LCN-HRM allowed these mutations to be identified by direct sequencing of those positive reactions.LCN-HRM was then used to review formalin-fixed paraffin-embedded (FFPE) clinical samples showing discordant findings between sequencing and HRM for KRAS exon 2 and EGFR exons 19 and 21. Both true mutations present at low levels and sequence changes due to artefacts were detected by LCN-HRM. The use of high fidelity polymerases showed that the majority of the artefacts were derived from the damaged template rather than replication errors during amplification. LCN-HRM bridges the sensitivity gap between HRM and sequencing and is effective in distinguishing between artefacts and true mutations.

  14. A follow up study of occupational exposure to 4,4'-methylene-bis(2-chloroaniline) (MbOCA) and isocyanates in polyurethane manufacture in the UK.

    PubMed

    Keen, C; Coldwell, M; McNally, K; Baldwin, P; McAlinden, J; Cocker, J

    2012-08-13

    This is a follow up survey of exposure to 4,4'-methylene-bis(2-chloroaniline) (MbOCA) and isocyanates in the UK polyurethane industry. Urine samples (n=446) were collected from 90 different workers. MbOCA levels were below the limit of detection in 170 samples and 26 were above the UK Biological Monitoring Guidance Value (BMGV) of 15 μmol MbOCA/mol creatinine. Detailed advice and guidance was given to each workplace at the end of the survey in 2008 and the 90% value reduced from 10 to 3 μmol MbOCA/mol creatinine in samples collected since. There was a positive correlation between glove contamination and urinary MbOCA and levels were dependent upon individual working practices especially how gloves were used. Of the 446 samples analysed for urinary metabolites of toluene diisocyanate 280 were below the detection limit and 126 were above the BMGV (1 μmol/mol creatinine). Of the 326 urine samples that were analysed for metabolites of methylenediphenyl diisocyanate, 270 were below the detection limit and 13 were above the BMGV for isocyanates. There was no correlation between urinary levels of isocyanates and MbOCA suggesting different routes of absorption, most likely inhalation and dermal respectively. Crown Copyright © 2011. Published by Elsevier Ireland Ltd. All rights reserved.

  15. Feasibility of shutter-speed DCE-MRI for improved prostate cancer detection.

    PubMed

    Li, Xin; Priest, Ryan A; Woodward, William J; Tagge, Ian J; Siddiqui, Faisal; Huang, Wei; Rooney, William D; Beer, Tomasz M; Garzotto, Mark G; Springer, Charles S

    2013-01-01

    The feasibility of shutter-speed model dynamic-contrast-enhanced MRI pharmacokinetic analyses for prostate cancer detection was investigated in a prebiopsy patient cohort. Differences of results from the fast-exchange-regime-allowed (FXR-a) shutter-speed model version and the fast-exchange-limit-constrained (FXL-c) standard model are demonstrated. Although the spatial information is more limited, postdynamic-contrast-enhanced MRI biopsy specimens were also examined. The MRI results were correlated with the biopsy pathology findings. Of all the model parameters, region-of-interest-averaged K(trans) difference [ΔK(trans) ≡ K(trans)(FXR-a) - K(trans)(FXL-c)] or two-dimensional K(trans)(FXR-a) vs. k(ep)(FXR-a) values were found to provide the most useful biomarkers for malignant/benign prostate tissue discrimination (at 100% sensitivity for a population of 13, the specificity is 88%) and disease burden determination. (The best specificity for the fast-exchange-limit-constrained analysis is 63%, with the two-dimensional plot.) K(trans) and k(ep) are each measures of passive transcapillary contrast reagent transfer rate constants. Parameter value increases with shutter-speed model (relative to standard model) analysis are larger in malignant foci than in normal-appearing glandular tissue. Pathology analyses verify the shutter-speed model (FXR-a) promise for prostate cancer detection. Parametric mapping may further improve pharmacokinetic biomarker performance. Copyright © 2012 Wiley Periodicals, Inc.

  16. Optimization of the sensitivity/doses relationship for a bench-top EDXRF system used for in vivo quantification of gold nanoparticles.

    PubMed

    Santibáñez, M; Saavedra, R; Vásquez, M; Malano, F; Pérez, P; Valente, M; Figueroa, R G

    2017-11-01

    The present work is devoted to optimizing the sensitivity-doses relationship of a bench-top EDXRF system, with the aim of achieving a detection limit of 0.010mg/ml of gold nanoparticles in tumor tissue (clinical values expected), for doses below 10mGy (value fixed for in vivo application). Tumor phantoms of 0.3cm 3 made of a suspension of gold nanoparticles (15nm AurovistTM, Nanoprobes Inc.) were studied at depths of 0-4mm in a tissue equivalent cylindrical phantom. The optimization process was implemented configuring several tube voltages and aluminum filters, to obtain non-symmetrical narrow spectra with fixed FWHM of 5keV and centered among the 11.2-20.3keV. The used statistical figure of merit was the obtained sensitivity (with each spectrum at each depth) weighted by the delivered surface doses. The detection limit of the system was determined measuring several gold nanoparticles concentrations ranging from 0.0010 to 5.0mg/ml and a blank sample into tumor phantoms, considering a statistical fluctuation within 95% of confidence. The results show the possibility of obtaining a detection limit for gold nanoparticles concentrations around 0.010mg/ml for surface tumor phantoms requiring doses around 2mGy. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Contributions and Limitations of National Cervical Cancer Screening Program in Korea: A Retrospective Observational Study.

    PubMed

    Lee, Jung Hyun; Kim, Hyeongsu; Choi, Heejung; Jeong, Hyoseon; Ko, Young; Shim, Seung-Hyuk; Lee, Eunjoo; Chae, Su Hyun

    2018-03-01

    The purpose of this study was to evaluate the contributions and limitations of the cervical cancer screening test with accuracy in Korea. This was a retrospective observational study. The study population consisted of all participants who underwent cervical cancer screening test from 2009 to 2014. The data were obtained from National Health Information Database (NHID) which represents medical use records of most Koreans. As the indices for contributions and limitations of the screening test, crude detection rate, incidence rate of interval cancer, sensitivity, specificity, and positive predictive value were used. The crude detection rate of screening test per 100,000 participants increased from 100.7 in 2009 to 102.1 in 2014. The incidence rate of interval cancer per 100,000 negatives decreased from 13.0 in 2009 to 10.2 in 2014. The sensitivities of screening test were 88.7% in 2009 and 91.2% in 2014, and the specificities were 98.5% in 2009 and 97.7% in 2014. The positive predictive value of screening decreased from 6.2% in 2009 to 4.3% in 2014. The Korean national cervical cancer screening program has improved in accuracy and has contributed to detection of early stage of cervical cancer over the years. Along with efforts to promote participation in cancer screening programs, quality control over the screening program should be enhanced. Copyright © 2018. Published by Elsevier B.V.

  18. European multicenter analytical evaluation of the Abbott ARCHITECT STAT high sensitive troponin I immunoassay.

    PubMed

    Krintus, Magdalena; Kozinski, Marek; Boudry, Pascal; Capell, Nuria Estañ; Köller, Ursula; Lackner, Karl; Lefèvre, Guillaume; Lennartz, Lieselotte; Lotz, Johannes; Herranz, Antonio Mora; Nybo, Mads; Plebani, Mario; Sandberg, Maria B; Schratzberger, Wolfgang; Shih, Jessie; Skadberg, Øyvind; Chargui, Ahmed Taoufik; Zaninotto, Martina; Sypniewska, Grazyna

    2014-11-01

    International recommendations highlight the superior value of cardiac troponins (cTns) for early diagnosis of myocardial infarction along with analytical requirements of improved precision and detectability. In this multicenter study, we investigated the analytical performance of a new high sensitive cardiac troponin I (hs-cTnI) assay and its 99th percentile upper reference limit (URL). Laboratories from nine European countries evaluated the ARCHITECT STAT high sensitive troponin I (hs-TnI) immunoassay on the ARCHITECT i2000SR/i1000SR immunoanalyzers. Imprecision, limit of blank (LoB), limit of detection (LoD), limit of quantitation (LoQ) linearity of dilution, interferences, sample type, method comparisons, and 99th percentile URLs were evaluated in this study. Total imprecision of 3.3%-8.9%, 2.0%-3.5% and 1.5%-5.2% was determined for the low, medium and high controls, respectively. The lowest cTnI concentration corresponding to a total CV of 10% was 5.6 ng/L. Common interferences, sample dilution and carryover did not affect the hs-cTnI results. Slight, but statistically significant, differences with sample type were found. Concordance between the investigated hs-cTnI assay and contemporary cTnI assay at 99th percentile cut-off was found to be 95%. TnI was detectable in 75% and 57% of the apparently healthy population using the lower (1.1 ng/L) and upper (1.9 ng/L) limit of the LoD range provided by the ARCHITECT STAT hs-TnI package insert, respectively. The 99th percentile values were gender dependent. The new ARCHITECT STAT hs-TnI assay with improved analytical features meets the criteria of high sensitive Tn test and will be a valuable diagnostic tool.

  19. Thermodynamic framework to assess low abundance DNA mutation detection by hybridization.

    PubMed

    Willems, Hanny; Jacobs, An; Hadiwikarta, Wahyu Wijaya; Venken, Tom; Valkenborg, Dirk; Van Roy, Nadine; Vandesompele, Jo; Hooyberghs, Jef

    2017-01-01

    The knowledge of genomic DNA variations in patient samples has a high and increasing value for human diagnostics in its broadest sense. Although many methods and sensors to detect or quantify these variations are available or under development, the number of underlying physico-chemical detection principles is limited. One of these principles is the hybridization of sample target DNA versus nucleic acid probes. We introduce a novel thermodynamics approach and develop a framework to exploit the specific detection capabilities of nucleic acid hybridization, using generic principles applicable to any platform. As a case study, we detect point mutations in the KRAS oncogene on a microarray platform. For the given platform and hybridization conditions, we demonstrate the multiplex detection capability of hybridization and assess the detection limit using thermodynamic considerations; DNA containing point mutations in a background of wild type sequences can be identified down to at least 1% relative concentration. In order to show the clinical relevance, the detection capabilities are confirmed on challenging formalin-fixed paraffin-embedded clinical tumor samples. This enzyme-free detection framework contains the accuracy and efficiency to screen for hundreds of mutations in a single run with many potential applications in molecular diagnostics and the field of personalised medicine.

  20. Limit of detection of 15{sub N} by gas-chromatography atomic emission detection: Optimization using an experimental design

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Deruaz, D.; Bannier, A.; Pionchon, C.

    1995-08-01

    This paper deals with the optimal conditions for the detection of {sup 15}N determined using a four-factor experimental design from [2{sup 13}C,-1,3 {sup 15}N] caffeine measured with an atomic emission detector (AED) coupled to gas chromatography (GC). Owing to the capability of a photodiodes array, AED can simultaneously detect several elements using their specific emission lines within a wavelength range of 50 nm. So, the emissions of {sup 15}N and {sup 14}N are simultaneously detected at 420.17 nm and 421.46 nm respectively. Four independent experimental factors were tested (1) helium flow rate (plasma gas); (2) methane pressure (reactant gas); (3)more » oxygen pressure; (4) hydrogen pressure. It has been shown that these four gases had a significant influence on the analytical response of {sup 15}N. The linearity of the detection was determined using {sup 15}N amounts ranging from 1.52 pg to 19 ng under the optimal conditions obtained from the experimental design. The limit of detection was studied using different methods. The limits of detection of {sup 15}N was 1.9 pg/s according to the IUPAC method (International-Union of Pure and Applied Chemistry). The method proposed by Quimby and Sullivan gave a value of 2.3 pg/s and that of Oppenheimer gave a limit of 29 pg/s. For each determination, and internal standard: 1-isobutyl-3.7 dimethylxanthine was used. The results clearly demonstrate that GC AED is sensitive and selective enough to detect and measure {sup 15}N-labelled molecules after gas chromatographic separation.« less

  1. Hybrid online sensor error detection and functional redundancy for systems with time-varying parameters.

    PubMed

    Feng, Jianyuan; Turksoy, Kamuran; Samadi, Sediqeh; Hajizadeh, Iman; Littlejohn, Elizabeth; Cinar, Ali

    2017-12-01

    Supervision and control systems rely on signals from sensors to receive information to monitor the operation of a system and adjust manipulated variables to achieve the control objective. However, sensor performance is often limited by their working conditions and sensors may also be subjected to interference by other devices. Many different types of sensor errors such as outliers, missing values, drifts and corruption with noise may occur during process operation. A hybrid online sensor error detection and functional redundancy system is developed to detect errors in online signals, and replace erroneous or missing values detected with model-based estimates. The proposed hybrid system relies on two techniques, an outlier-robust Kalman filter (ORKF) and a locally-weighted partial least squares (LW-PLS) regression model, which leverage the advantages of automatic measurement error elimination with ORKF and data-driven prediction with LW-PLS. The system includes a nominal angle analysis (NAA) method to distinguish between signal faults and large changes in sensor values caused by real dynamic changes in process operation. The performance of the system is illustrated with clinical data continuous glucose monitoring (CGM) sensors from people with type 1 diabetes. More than 50,000 CGM sensor errors were added to original CGM signals from 25 clinical experiments, then the performance of error detection and functional redundancy algorithms were analyzed. The results indicate that the proposed system can successfully detect most of the erroneous signals and substitute them with reasonable estimated values computed by functional redundancy system.

  2. TU-FG-201-09: Predicting Accelerator Dysfunction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Able, C; Nguyen, C; Baydush, A

    Purpose: To develop an integrated statistical process control (SPC) framework using digital performance and component data accumulated within the accelerator system that can detect dysfunction prior to unscheduled downtime. Methods: Seven digital accelerators were monitored for twelve to 18 months. The accelerators were operated in a ‘run to failure mode’ with the individual institutions determining when service would be initiated. Institutions were required to submit detailed service reports. Trajectory and text log files resulting from a robust daily VMAT QA delivery were decoded and evaluated using Individual and Moving Range (I/MR) control charts. The SPC evaluation was presented in amore » customized dashboard interface that allows the user to review 525 monitored parameters (480 MLC parameters). Chart limits were calculated using a hybrid technique that includes the standard SPC 3σ limits and an empirical factor based on the parameter/system specification. The individual (I) grand mean values and control limit ranges of the I/MR charts of all accelerators were compared using statistical (ranked analysis of variance (ANOVA)) and graphical analyses to determine consistency of operating parameters. Results: When an alarm or warning was directly connected to field service, process control charts predicted dysfunction consistently on beam generation related parameters (BGP)– RF Driver Voltage, Gun Grid Voltage, and Forward Power (W); beam uniformity parameters – angle and position steering coil currents; and Gantry position accuracy parameter: cross correlation max-value. Control charts for individual MLC – cross correlation max-value/position detected 50% to 60% of MLCs serviced prior to dysfunction or failure. In general, non-random changes were detected 5 to 80 days prior to a service intervention. The ANOVA comparison of BGP determined that each accelerator parameter operated at a distinct value. Conclusion: The SPC framework shows promise. Long term monitoring coordinated with service will be required to definitively determine the effectiveness of the model. Varian Medical System, Inc. provided funding in support of the research presented.« less

  3. Comparison of the Abbott m2000 HIV-1 Real-Time and Roche AMPLICOR Monitor v1.5 HIV-1 assays on plasma specimens from Rakai, Uganda.

    PubMed

    Ssebugenyi, I; Kizza, A; Mpoza, B; Aluma, G; Boaz, I; Newell, K; Laeyendecker, O; Shott, J P; Serwadda, D; Reynolds, S J

    2011-07-01

    The need for viral load (VL) monitoring of HIV patients receiving antiretroviral therapy (ART) in resource-limited settings (RLS) has become apparent with studies showing the limitations of immunological monitoring. We compared the Abbott m2000 Real-Time (Abbott) HIV-1 assay with the Roche AMPLICOR Monitor v1.5 (Roche) HIV-1 assay over a range of VL concentrations. Three hundred and eleven plasma samples were tested, including 164 samples from patients on ART ≥ six months and 147 from ART-naïve patients. The Roche assay detected ≥400 copies/mL in 158 (50.8%) samples. Of these, Abbott produced 145 (91.8%) detectable results ≥400 copies/mL; 13 (8.2%) samples produced discrepant results. Concordance between the assays for detecting HIV-1 RNA ≥400 copies/mL was 95.8% (298/311). The sensitivity, specificity, positive predictive value and negative predictive value of Abbott to detect HIV-1 RNA ≥400 copies/mL were 91.8%, 100%, 100% and 92.2%, respectively. For the 151 samples with HIV-1 RNA ≥400 copies/mL for both assays, a good linear correlation was found (r = 0.81, P < 0.0001; mean difference, 0.05). The limits of agreement were -0.97 and 1.07 log(10) copies/mL (mean ± 2 SD). The Abbott assay performed well in our setting, offering an alternative methodology for HIV-1 VL for laboratories with realtime polymerase chain reaction (PCR) capacity.

  4. RF Tomography for Tunnel Detection: Principles and Inversion Schemes

    NASA Astrophysics Data System (ADS)

    Lo Monte, L.; Erricolo, D.; Inan, U. S.; Wicks, M. C.

    2008-12-01

    We propose a novel way to detect underground tunnels based on classical seismic tomography, Ground Penetrating Radar (GPR), inverse scattering principles, and the deployment of distributed sensors, which we call "Distributed RF Tomography". Tunnel detection has been a critical problem that cannot be considered fully solved. Presently, tunnel detection is performed by methods that include seismic sensors, electrical impedance, microgravity, boreholes, and GPR. All of these methods have drawbacks that make them not applicable for use in unfriendly environments, such as battlefields. Specifically, they do not cover wide surface areas, they are generally shallow, they are limited to vertical prospecting, and require the user to be in situ, which may jeopardize one's safety. Additional application of the proposed distributed RF tomography include monitoring sensitive areas, (e.g. banks, power plants, military bases, prisons, national borders) and civil applications (e.g. environmental engineering, mine safety, search and rescue, speleology, archaeology and geophysics). The novelty of a Distributed RF tomography system consists of the following. 1) Sensors are scattered randomly above the ground, thus saving time and money compared to the use of boreholes. 2) The use of lower operating frequency (around HF), which allows for deeper penetration. 3) The use of CW diffraction tomography, which increases the resolution to sub-wavelength values, independently from the sensor displacement, and increases the SNR. 4) Use of linear inversion schemes that are suited for tunnel detection. 5) The use of modulation schemes and signal processing algorithms to mitigate interferences and noise. This presentation will cover: 1. Current physical limits of existing techniques for tunnel detection. 2. Concept of Distributed RF Tomography. 3. Inversion theories and strategies a. Proper forward model for voids buried into an homogeneous medium b. Extended matched filtering inversion c. Near field formulation : Dyadic representation d. Fourier approach: principles and techniques aimed at improving the reconstructed image. e. Theoretical Limits f. Super-Resolution : Singular Values Decomposition and MUSIC 4. Propagation Model and theoretical limitations. 5. Transmitting and Receiving design, with signal processing and modulation. 6. Numerical Simulations using FDTD tools.

  5. Limits of detection and decision. Part 3

    NASA Astrophysics Data System (ADS)

    Voigtman, E.

    2008-02-01

    It has been shown that the MARLAP (Multi-Agency Radiological Laboratory Analytical Protocols) for estimating the Currie detection limit, which is based on 'critical values of the non-centrality parameter of the non-central t distribution', is intrinsically biased, even if no calibration curve or regression is used. This completed the refutation of the method, begun in Part 2. With the field cleared of obstructions, the true theory underlying Currie's limits of decision, detection and quantification, as they apply in a simple linear chemical measurement system (CMS) having heteroscedastic, Gaussian measurement noise and using weighted least squares (WLS) processing, was then derived. Extensive Monte Carlo simulations were performed, on 900 million independent calibration curves, for linear, "hockey stick" and quadratic noise precision models (NPMs). With errorless NPM parameters, all the simulation results were found to be in excellent agreement with the derived theoretical expressions. Even with as much as 30% noise on all of the relevant NPM parameters, the worst absolute errors in rates of false positives and false negatives, was only 0.3%.

  6. Multiple imputation for multivariate data with missing and below-threshold measurements: time-series concentrations of pollutants in the Arctic.

    PubMed

    Hopke, P K; Liu, C; Rubin, D B

    2001-03-01

    Many chemical and environmental data sets are complicated by the existence of fully missing values or censored values known to lie below detection thresholds. For example, week-long samples of airborne particulate matter were obtained at Alert, NWT, Canada, between 1980 and 1991, where some of the concentrations of 24 particulate constituents were coarsened in the sense of being either fully missing or below detection limits. To facilitate scientific analysis, it is appealing to create complete data by filling in missing values so that standard complete-data methods can be applied. We briefly review commonly used strategies for handling missing values and focus on the multiple-imputation approach, which generally leads to valid inferences when faced with missing data. Three statistical models are developed for multiply imputing the missing values of airborne particulate matter. We expect that these models are useful for creating multiple imputations in a variety of incomplete multivariate time series data sets.

  7. Rapid Development and Validation of Improved Reversed-Phase High-performance Liquid Chromatography Method for the Quantification of Mangiferin, a Polyphenol Xanthone Glycoside in Mangifera indica

    PubMed Central

    Naveen, P.; Lingaraju, H. B.; Prasad, K. Shyam

    2017-01-01

    Mangiferin, a polyphenolic xanthone glycoside from Mangifera indica, is used as traditional medicine for the treatment of numerous diseases. The present study was aimed to develop and validate a reversed-phase high-performance liquid chromatography (RP-HPLC) method for the quantification of mangiferin from the bark extract of M. indica. RP-HPLC analysis was performed by isocratic elution with a low-pressure gradient using 0.1% formic acid: acetonitrile (87:13) as a mobile phase with a flow rate of 1.5 ml/min. The separation was done at 26°C using a Kinetex XB-C18 column as stationary phase and the detection wavelength at 256 nm. The proposed method was validated for linearity, precision, accuracy, limit of detection, limit of quantification, and robustness by the International Conference on Harmonisation guidelines. In linearity, the excellent correlation coefficient more than 0.999 indicated good fitting of the curve and also good linearity. The intra- and inter-day precision showed < 1% of relative standard deviation of peak area indicated high reliability and reproducibility of the method. The recovery values at three different levels (50%, 100%, and 150%) of spiked samples were found to be 100.47, 100.89, and 100.99, respectively, and low standard deviation value < 1% shows high accuracy of the method. In robustness, the results remain unaffected by small variation in the analytical parameters, which shows the robustness of the method. Liquid chromatography–mass spectrometry analysis confirmed the presence of mangiferin with M/Z value of 421. The assay developed by HPLC method is a simple, rapid, and reliable for the determination of mangiferin from M. indica. SUMMARY The present study was intended to develop and validate an RP-HPLC method for the quantification of mangiferin from the bark extract of M. indica. The developed method was validated for linearity, precision, accuracy, limit of detection, limit of quantification and robustness by International Conference on Harmonization guidelines. This study proved that the developed assay by HPLC method is a simple, rapid and reliable for the quantification of the mangiferin from M. indica. Abbreviations Used: M. indica: Mangifera indica, RP-HPLC: Reversed-phase high-performance liquid chromatography, M/Z: Mass to charge ratio, ICH: International conference on harmonization, % RSD: Percentage of relative standard deviation, ppm: Parts per million, LOD: Limit of detection, LOQ: Limit of quantification. PMID:28539748

  8. Rapid Development and Validation of Improved Reversed-Phase High-performance Liquid Chromatography Method for the Quantification of Mangiferin, a Polyphenol Xanthone Glycoside in Mangifera indica.

    PubMed

    Naveen, P; Lingaraju, H B; Prasad, K Shyam

    2017-01-01

    Mangiferin, a polyphenolic xanthone glycoside from Mangifera indica , is used as traditional medicine for the treatment of numerous diseases. The present study was aimed to develop and validate a reversed-phase high-performance liquid chromatography (RP-HPLC) method for the quantification of mangiferin from the bark extract of M. indica . RP-HPLC analysis was performed by isocratic elution with a low-pressure gradient using 0.1% formic acid: acetonitrile (87:13) as a mobile phase with a flow rate of 1.5 ml/min. The separation was done at 26°C using a Kinetex XB-C18 column as stationary phase and the detection wavelength at 256 nm. The proposed method was validated for linearity, precision, accuracy, limit of detection, limit of quantification, and robustness by the International Conference on Harmonisation guidelines. In linearity, the excellent correlation coefficient more than 0.999 indicated good fitting of the curve and also good linearity. The intra- and inter-day precision showed < 1% of relative standard deviation of peak area indicated high reliability and reproducibility of the method. The recovery values at three different levels (50%, 100%, and 150%) of spiked samples were found to be 100.47, 100.89, and 100.99, respectively, and low standard deviation value < 1% shows high accuracy of the method. In robustness, the results remain unaffected by small variation in the analytical parameters, which shows the robustness of the method. Liquid chromatography-mass spectrometry analysis confirmed the presence of mangiferin with M/Z value of 421. The assay developed by HPLC method is a simple, rapid, and reliable for the determination of mangiferin from M. indica . The present study was intended to develop and validate an RP-HPLC method for the quantification of mangiferin from the bark extract of M. indica . The developed method was validated for linearity, precision, accuracy, limit of detection, limit of quantification and robustness by International Conference on Harmonization guidelines. This study proved that the developed assay by HPLC method is a simple, rapid and reliable for the quantification of the mangiferin from M. indica . Abbreviations Used: M. indica : Mangifera indica , RP-HPLC: Reversed-phase high-performance liquid chromatography, M/Z: Mass to charge ratio, ICH: International conference on harmonization, % RSD: Percentage of relative standard deviation, ppm: Parts per million, LOD: Limit of detection, LOQ: Limit of quantification.

  9. Multifunctional paper strip based on GO-veiled Ag nanoparticles with highly SERS sensitive and deliverable properties for high-performance molecular detection.

    PubMed

    Yang, Cheng; Xu, Yuanyuan; Wang, Minghong; Li, Tianming; Huo, Yanyan; Yang, Chuanxi; Man, Baoyuan

    2018-04-16

    The development of paper-based SERS substrates that can allow multi-component detection in real-word scenarios is of great value for applications in molecule detection under complex conditions. Here, a multifunctional SERS-based paper sensing substrate has been developed through the uniform patterning of high-density arrays of GO-isolated Ag nanoparticles on the hydrophilic porous cellulose paper strip (GO@AgNP@paper). Wet-chemical synthesis was used to provide the cover of SERS hot spots on any part of the paper, not just limited surface deposition. In virtue of the inherent ability of paper to deliver analytes by the capillary force, the detection ability of the GO@AgNP@paper substrate was greatly promoted, allowing as low as 10 -19 M R6G detection from microliter-volume (50 μL) samples. For the components with different polarity, the paper substrate can be used as an all-in-one machine to achieve the integration of separation and high-sensitive detection for ultralow mixture components, which improves the practical application value of SERS-based paper devices.

  10. Differences between automatically detected and steady-state fractional flow reserve.

    PubMed

    Härle, Tobias; Meyer, Sven; Vahldiek, Felix; Elsässer, Albrecht

    2016-02-01

    Measurement of fractional flow reserve (FFR) has become a standard diagnostic tool in the catheterization laboratory. FFR evaluation studies were based on pressure recordings during steady-state maximum hyperemia. Commercially available computer systems detect the lowest Pd/Pa ratio automatically, which might not always be measured during steady-state hyperemia. We sought to compare the automatically detected FFR and true steady-state FFR. Pressure measurement traces of 105 coronary lesions from 77 patients with intermediate coronary lesions or multivessel disease were reviewed. In all patients, hyperemia had been achieved by intravenous adenosine administration using a dosage of 140 µg/kg/min. In 42 lesions (40%) automatically detected FFR was lower than true steady-state FFR. Mean bias was 0.009 (standard deviation 0.015, limits of agreement -0.02, 0.037). In 4 lesions (3.8%) both methods lead to different treatment recommendations, in all 4 cases instantaneous wave-free ratio confirmed steady-state FFR. Automatically detected FFR was slightly lower than steady-state FFR in more than one-third of cases. Consequently, interpretation of automatically detected FFR values closely below the cutoff value requires special attention.

  11. An endogenous reference gene of common and durum wheat for detection of genetically modified wheat.

    PubMed

    Imai, Shinjiro; Tanaka, Keiko; Nishitsuji, Yasuyuki; Kikuchi, Yosuke; Matsuoka, Yasuyuki; Arami, Shin-Ichiro; Sato, Megumi; Haraguchi, Hiroyuki; Kurimoto, Youichi; Mano, Junichi; Furui, Satoshi; Kitta, Kazumi

    2012-01-01

    To develop a method for detecting GM wheat that may be marketed in the near future, we evaluated the proline-rich protein (PRP) gene as an endogenous reference gene of common wheat (Triticum aestivum L.) and durum wheat (Triticum durum L.). Real-time PCR analysis showed that only DNA of wheat was amplified and no amplification product was observed for phylogenetically related cereals, indicating that the PRP detection system is specific to wheat. The intensities of the amplification products and Ct values among all wheat samples used in this study were very similar, with no nonspecific or additional amplification, indicating that the PRP detection system has high sequence stability. The limit of detection was estimated at 5 haploid genome copies. The PRP region was demonstrated to be present as a single or double copy in the common wheat haploid genome. Furthermore, the PRP detection system showed a highly linear relationship between Ct values and the amount of plasmid DNA, indicating that an appropriate calibration curve could be constructed for quantitative detection of GM wheat. All these results indicate that the PRP gene is a suitable endogenous reference gene for PCR-based detection of GM wheat.

  12. How valuable is physical examination of the cardiovascular system?

    PubMed

    Elder, Andrew; Japp, Alan; Verghese, Abraham

    2016-07-27

    Physical examination of the cardiovascular system is central to contemporary teaching and practice in clinical medicine. Evidence about its value focuses on its diagnostic accuracy and varies widely in methodological quality and statistical power. This makes collation, analysis, and understanding of results difficult and limits their application to daily clinical practice. Specific factors affecting interpretation and clinical application include poor standardisation of observers' technique and training, the study of single signs rather than multiple signs or signs in combination with symptoms, and the tendency to compare physical examination directly with technological aids to diagnosis rather than explore diagnostic strategies that combine both. Other potential aspects of the value of physical examination, such as cost effectiveness or patients' perceptions, are poorly studied. This review summarises the evidence for the clinical value of physical examination of the cardiovascular system. The best was judged to relate to the detection and evaluation of valvular heart disease, the diagnosis and treatment of heart failure, the jugular venous pulse in the assessment of central venous pressure, and the detection of atrial fibrillation, peripheral arterial disease, impaired perfusion, and aortic and carotid disease. Although technological aids to diagnosis are likely to become even more widely available at the point of care, the evidence suggests that further research into the value of physical examination of the cardiovascular system is needed, particularly in low resource settings and as a potential means of limiting inappropriate overuse of technological aids to diagnosis. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  13. ANALYTICAL METHOD COMPARISONS BY ESTIMATES OF PRECISION AND LOWER DETECTION LIMIT

    EPA Science Inventory

    The paper describes the use of principal component analysis to estimate the operating precision of several different analytical instruments or methods simultaneously measuring a common sample of a material whose actual value is unknown. This approach is advantageous when none of ...

  14. Simultaneous HPTLC Determination of Rabeprazole and Itopride Hydrochloride From Their Combined Dosage Form.

    PubMed

    Suganthi, A; John, Sofiya; Ravi, T K

    2008-01-01

    A simple, precise, sensitive, rapid and reproducible HPTLC method for the simultaneous estimation of the rabeprazole and itopride hydrochloride in tablets was developed and validated. This method involves separation of the components by TLC on precoated silica gel G60F254 plate with solvent system of n-butanol, toluene and ammonia (8.5:0.5:1 v/v/v) and detection was carried out densitometrically using a UV detector at 288 nm in absorbance mode. This system was found to give compact spots for rabeprazole (Rf value of 0.23 0.02) and for itopride hydrochloride (Rf value of 0.75+/-0.02). Linearity was found to be in the range of 40-200 ng/spot and 300-1500 ng/spot for rabeprazole and itopride hydrochloride. The limit of detection and limit of quantification for rabeprazole were 10 and 20 ng/spot and for itopride hydrochloride were 50 and 100 ng/spot, respectively. The method was found to be beneficial for the routine analysis of combined dosage form.

  15. An ultrasensitive SiO2-encapsulated alloyed CdZnSeS quantum dot-molecular beacon nanobiosensor for norovirus.

    PubMed

    Adegoke, Oluwasesan; Seo, Min-Woong; Kato, Tatsuya; Kawahito, Shoji; Park, Enoch Y

    2016-12-15

    Ultrasensitive, rapid and selective diagnostic probes are urgently needed to overcome the limitations of traditional probes for norovirus (NV). Here, we report the detection of NV genogroup II via nucleic acid hybridization technology using a quantum dot (QD)-conjugated molecular beacon (MB) probe. To boost the sensitivity of the MB assay system, an ultrasensitive QD fluorophore with unique optical properties was synthesized, characterized and exploited as a fluorescence signal generator. Alloyed thioglycolic (TGA)-capped CdZnSeS QDs with a high photoluminescence (PL) quantum yield (QY) value of 92% were synthesized, and a modified silanization method was employed to encapsulate the thiol-capped QDs in a silica layer. The resulting highly luminescent alloyed SiO2-coated CdZnSeS QDs had a remarkable PL QY value of 98%. Transmission electron microscopy and dynamic light scattering confirmed the monodispersity of the alloyed nanocrystals, and zeta potential analysis confirmed their colloidal stability. Powder X-ray diffraction and PL lifetime measurements confirmed the surface modification of the QDs. The alloyed TGA-capped and SiO2-coated CdZnSeS QD-conjugated MB bioprobes detected extremely low concentrations of NV RNA. Ultrasensitive detection of low concentrations of NV RNA with a limit of detection (LOD) of 8.2copies/mL in human serum and a LOD of 9.3 copies/mL in buffer was achieved using the SiO2-coated CdZnSeS QD-MB probes, an increase in sensitivity of 3-fold compared with the detection limit for NV RNA using TGA-capped CdZnSeS QD-MBs. The additional merits of our detection system are rapidity, specificity and improved sensitivity over conventional molecular test probes. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  16. Limits of linearity and detection for some drugs of abuse.

    PubMed

    Needleman, S B; Romberg, R W

    1990-01-01

    The limits of linearity (LOL) and detection (LOD) are important factors in establishing the reliability of an analytical procedure for accurately assaying drug concentrations in urine specimens. Multiple analyses of analyte over an extended range of concentrations provide a measure of the ability of the analytical procedure to correctly identify known quantities of drug in a biofluid matrix. Each of the seven drugs of abuse gives linear analytical responses from concentrations at or near their LOD to concentrations several-fold higher than those generally encountered in the drug screening laboratory. The upper LOL exceeds the Department of Navy (DON) cutoff values by factors of approximately 2 to 160. The LOD varies from 0.4 to 5.0% of the DON cutoff value for each drug. The limit of quantitation (LOQ) is calculated as the LOD + 7 SD. The range for LOL is greater for drugs analyzed with deuterated internal standards compared with those using conventional internal standards. For THC acid, cocaine, PCP, and morphine, LOLs are 8 to 160-fold greater than the defined cutoff concentrations. For the other drugs, the LOL's are only 2 to 4-fold greater than the defined cutoff concentrations.

  17. Liquid chromatographic determination of 9-methyl-3-(1H-tetrazol-5-yl)-4H-pyrido[1,2-a]pyrimidin-4-one in human plasma with fluorescence detection.

    PubMed

    Cheng, H; Pittman, K A; Dandekar, K A

    1987-12-01

    A simple and sensitive assay for quantitating 9-methyl-3-(1H-tetrazol-5-yl)-4H-pyrido[1,2-a]pyrimidin-4-one (1; BMY 26517) in human plasma was developed using high-performance liquid chromatography with fluorescence detection. The method involves precipitation of protein and reversed-phase chromatography. The method is linear in the range of 4.3-429 ng/mL of 1, and the limit of detection is 0.4 ng/mL. The day-to-day precision values of this method at 25.7 and 386 ng/mL are 2.1 and 2.6%, respectively. The day-to-day accuracy values at these concentrations are 99.7 and 99.8%, respectively. The recovery of 1 is 98.3%.

  18. Determination of glucosinolates in rapeseed and Thlaspi caerulescens plants by liquid chromatography-atmospheric pressure chemical ionization mass spectrometry.

    PubMed

    Tolrà, R P; Alonso, R; Poschenrieder, C; Barceló, D; Barceló, J

    2000-08-11

    Liquid chromatography-atmospheric pressure chemical ionization mass spectrometry was used to identify glucosinolates in plant extracts. Optimization of the analytical conditions and the determination of the method detection limit was performed using commercial 2-propenylglucosinolate (sinigrin). Optimal values for the following parameters were determined: nebulization pressure, gas temperature, flux of drying gas, capillar voltage, corona current and fragmentor conditions. The method detection limit for sinigrin was 2.85 ng. For validation of the method the glucosinolates in reference material (rapeseed) from the Community Bureau of Reference Materials (BCR) were analyzed. The method was applied for the determination of glucosinolates in Thlaspi caerulescens plants.

  19. Human versus automation in responding to failures: an expected-value analysis

    NASA Technical Reports Server (NTRS)

    Sheridan, T. B.; Parasuraman, R.

    2000-01-01

    A simple analytical criterion is provided for deciding whether a human or automation is best for a failure detection task. The method is based on expected-value decision theory in much the same way as is signal detection. It requires specification of the probabilities of misses (false negatives) and false alarms (false positives) for both human and automation being considered, as well as factors independent of the choice--namely, costs and benefits of incorrect and correct decisions as well as the prior probability of failure. The method can also serve as a basis for comparing different modes of automation. Some limiting cases of application are discussed, as are some decision criteria other than expected value. Actual or potential applications include the design and evaluation of any system in which either humans or automation are being considered.

  20. Performance Characteristics of the Cepheid Xpert vanA Assay for Rapid Identification of Patients at High Risk for Carriage of Vancomycin-Resistant Enterococci

    PubMed Central

    Gilhuley, Kathleen; Cianciminio-Bordelon, Diane; Tang, Yi-Wei

    2012-01-01

    We compared the performance characteristics of culture and the Cepheid Xpert vanA assay for routine surveillance of vancomycin-resistant enterococci (VRE) from rectal swabs in patients at high risk for VRE carriage. The Cepheid Xpert vanA assay had a limit of detection of 100 CFU/ml and correctly detected 101 well-characterized clinical VRE isolates with no cross-reactivity in 27 non-VRE and related culture isolates. The clinical sensitivity, specificity, positive predictive value, and negative predictive value of the Xpert vanA PCR assay were 100%, 96.9%, 91.3%, and 100%, respectively, when tested on 300 consecutively collected rectal swabs. This assay provides excellent predictive values for prompt identification of VRE-colonized patients in hospitals with relatively high rates of VRE carriage. PMID:22972822

  1. Simultaneous detection of creatine and creatinine using a sequential injection analysis/biosensor system.

    PubMed

    Stefan-van Staden, Raluca-Ioana; Bokretsion, Rahel Girmai; van Staden, Jacobus F; Aboul-Enein, Hassan Y

    2006-01-01

    Carbon paste based biosensors for the determination of creatine and creatinine have been integrated into a sequential injection system. Applying the multi-enzyme sequence of creatininase (CA), and/or creatinase (CI) and sarcosine oxidase (SO), hydrogen peroxide has been detected amperometrically. The linear concentration ranges are of pmol/L to nmol/L magnitude, with very low limits of detection. The proposed SIA system can be utilized reliably for the on-line simultaneous detection of creatine and creatinine in pharmaceutical products, as well as in serum samples, with a rate of 34 samples per hour and RSD values better than 0.16% (n=10).

  2. Bacterial degradation of acetone in an outdoor model stream

    USGS Publications Warehouse

    Rathbun, R.E.; Stephens, D.W.; Tai, D.Y.

    1993-01-01

    Diurnal variations of the acetone concentration in an outdoor model stream were measured with and without a nitrate supplement to determine if the nitrate supplement would stimulate bacterial degradation of the acetone. Acetone loss coefficients were computed from the diurnal data using a fitting procedure based on a Lagrangian particle model. The coefficients indicated that bacterial degradation of the acetone was occurring in the downstream part of the stream during the nitrate addition. However, the acetone concentrations stabilized at values considerably above the limit of detection for acetone determination, in contrast to laboratory respirometer studies where the acetone concentration decreased rapidly to less than the detection limit, once bacterial acclimation to the acetone had occurred. One possible explanation for the difference in behavior was the limited 6-hour residence time of the acetone in the model stream.

  3. Rho GTPase Involvement in Breast Cancer Migration and Invasion

    DTIC Science & Technology

    2007-03-01

    knockdown was established for the kinase and phosphatase genes using branched DNA ( bDNA ) technology (Genospectra) in collaboration with Dharmacon RNA...knockdown value of ង% and of these, 80 genes were previously undetectable by bDNA in baseline detection analysis, reflecting the limited sensitivity of

  4. Application of a SERS-based lateral flow immunoassay strip for the rapid and sensitive detection of staphylococcal enterotoxin B

    NASA Astrophysics Data System (ADS)

    Hwang, Joonki; Lee, Sangyeop; Choo, Jaebum

    2016-06-01

    A novel surface-enhanced Raman scattering (SERS)-based lateral flow immunoassay (LFA) biosensor was developed to resolve problems associated with conventional LFA strips (e.g., limits in quantitative analysis and low sensitivity). In our SERS-based biosensor, Raman reporter-labeled hollow gold nanospheres (HGNs) were used as SERS detection probes instead of gold nanoparticles. With the proposed SERS-based LFA strip, the presence of a target antigen can be identified through a colour change in the test zone. Furthermore, highly sensitive quantitative evaluation is possible by measuring SERS signals from the test zone. To verify the feasibility of the SERS-based LFA strip platform, an immunoassay of staphylococcal enterotoxin B (SEB) was performed as a model reaction. The limit of detection (LOD) for SEB, as determined with the SERS-based LFA strip, was estimated to be 0.001 ng mL-1. This value is approximately three orders of magnitude more sensitive than that achieved with the corresponding ELISA-based method. The proposed SERS-based LFA strip sensor shows significant potential for the rapid and sensitive detection of target markers in a simplified manner.A novel surface-enhanced Raman scattering (SERS)-based lateral flow immunoassay (LFA) biosensor was developed to resolve problems associated with conventional LFA strips (e.g., limits in quantitative analysis and low sensitivity). In our SERS-based biosensor, Raman reporter-labeled hollow gold nanospheres (HGNs) were used as SERS detection probes instead of gold nanoparticles. With the proposed SERS-based LFA strip, the presence of a target antigen can be identified through a colour change in the test zone. Furthermore, highly sensitive quantitative evaluation is possible by measuring SERS signals from the test zone. To verify the feasibility of the SERS-based LFA strip platform, an immunoassay of staphylococcal enterotoxin B (SEB) was performed as a model reaction. The limit of detection (LOD) for SEB, as determined with the SERS-based LFA strip, was estimated to be 0.001 ng mL-1. This value is approximately three orders of magnitude more sensitive than that achieved with the corresponding ELISA-based method. The proposed SERS-based LFA strip sensor shows significant potential for the rapid and sensitive detection of target markers in a simplified manner. Electronic supplementary information (ESI) available. See DOI: 10.1039/c5nr07243c

  5. Measurement of free and bound malondialdehyde in plasma by high-performance liquid chromatography as the 2,4-dinitrophenylhydrazine derivative.

    PubMed

    Pilz, J; Meineke, I; Gleiter, C H

    2000-06-09

    We established a method for the detection of free and total (free and bound) malondialdehyde (MDA) in human plasma samples after derivatisation with 2,4-dinitrophenylhydrazine (DNPH). Free MDA was prepared by perchloric acid deproteinisation whereas an alkaline hydrolysation step for 30 min at 60 degrees C was introduced prior to protein precipitation for the determination of total MDA. Derivatisation was accomplished in 10 min at room temperature subsequently chromatographed by HPLC on a reversed-phase 3 microm C(18) column with UV detection (310 nm). The detection limit was 25 pmol/ml for free and 0.3 nmol/ml for total MDA. The recovery of MDA added to different human plasma samples was 93.6% (n=11; RSD 7.1%) for the hydrolysation procedure. In samples from 12 healthy volunteers who underwent a hypoxic treatment (13% O2 for 6 h) we estimated a baseline value of total MDA of 2.16 nmol/ml (SD 0.29) (ambient air) with a significant increase to 2.92 (nmol/ml, SD 0.57; P=0.01) after the end of this physiological oxidative stress challenge. Plasma values of free MDA in these samples were close to our detection limit. The presented technique can easily performed with an isocratic HPLC apparatus and provides highly specific results for MDA as do sophisticated GC-MS methods.

  6. Core-based intrinsic fiber-optic absorption sensor for the detection of volatile organic compounds

    NASA Astrophysics Data System (ADS)

    Klunder, Gregory L.; Russo, Richard E.

    1995-03-01

    A core-based intrinsic fiber-optic absorption sensor has been developed and tested for the detection of volatile organic compounds. The distal ends of transmitting and receiving fibers are connected by a small cylindrical section of an optically clear silicone rubber. The silicone rubber acts both as a light pipe and as a selective membrane into which the analyte molecules can diffuse. The sensor has been used to detect volatile organics (trichloroethylene, 1,1-dichloroethylene, and benzene) in both aqueous solutions and in the vapor phase or headspace. Absorption spectra obtained in the near-infrared (near-IR) provide qualitative and quantitative information about the analyte. Water, which has strong broad-band absorption in the near-IR, is excluded from the spectra because of the hydrophobic properties of the silicone rubber. The rate-limiting step is shown to be the diffusion through the Nernstian boundary layer surrounding the sensor and not the diffusion through the silicone polymer. The rate of analyte diffusion into the sensor, as measured by the t(sub 90) values (the time required for the sensor to reach 90% of the equilibrium value), is 30 min for measurements in aqueous solutions and approximately 3 min for measurements made in the headspace. The limit of detection obtained with this sensor is approximately 1.1 ppm for trichloroethylene in an aqueous solution.

  7. [Changes in phototaxical index of Daphnia carinata under electric field of direct current in response to Cr6+ and Hg2+].

    PubMed

    Wang, Fei-Xiang; Yuan, Ling; Huang, Jian-Guo

    2013-06-01

    In order to detect toxicants sensitively in water by phototaxity of Daphnia, we studied the influence of DC electric field on phototaxity of self-bred Daphnia carinata, a mono-clone with high phototaxity, and the changes of their phototaxity in response to Cr6+ and Hg2+ after the treatment of DC electric field. The result indicated that the treatment of DC electric field changed their phototaxical indexes from positive to negative as the electric density increased and the time prolonged. The criteria values that showed no sign of changes in the phototaxical index of Daphnia carinata were 0.01 mA for 5 min. However, the limit for detecting Cr6+ and Hg2+ by their phototaxical index decreased significantly after treatment with 0.01 mA/5 min. The detection limits were only 32 microg x L(-1) for Cr6+ and 4.2 microg x L(-1) for Hg2+ after this treatment, much lower than those without pretreatment (56 microg x L(-1) for Cr6+ and 5.6 microg x L(-1) for Hg2+, respectively). Therefore, appropriate DC electric field to pre-treat Daphnia could decrease the detection limit, widen the concentration range of detection, and increased the sensibilities in water monitoring.

  8. Comparison of Non-Culture-Based Methods for Detection of Systemic Fungal Infections, with an Emphasis on Invasive Candida Infections

    PubMed Central

    White, P. Lewis; Archer, Alice E.; Barnes, Rosemary A.

    2005-01-01

    The accepted limitations associated with classic culture techniques for the diagnosis of invasive fungal infections have lead to the emergence of many non-culture-based methods. With superior sensitivities and quicker turnaround times, non-culture-based methods may aid the diagnosis of invasive fungal infections. In this review of the diagnostic service, we assessed the performances of two antigen detection techniques (enzyme-linked immunosorbent assay [ELISA] and latex agglutination) with a molecular method for the detection of invasive Candida infection and invasive aspergillosis. The specificities for all three assays were high (≥97%), although the Candida PCR method had enhanced sensitivity over both ELISA and latex agglutination with values of 95%, 75%, and 25%, respectively. However, calculating significant sensitivity values for the Aspergillus detection methods was not feasible due to a low number of proven/probable cases. Despite enhanced sensitivity, the PCR method failed to detect nucleic acid in a probable case of invasive Candida infection that was detected by ELISA. In conclusion, both PCR and ELISA techniques should be used in unison to aid the detection of invasive fungal infections. PMID:15872239

  9. A System for Multiplexed Direct Electrical Detection of DNA Synthesis.

    PubMed

    Anderson, Erik P; Daniels, Jonathan S; Yu, Heng; Karhanek, Miloslav; Lee, Thomas H; Davis, Ronald W; Pourmand, Nader

    2008-01-29

    An electronic system for the multiplexed detection of DNA polymerization is designed and characterized. DNA polymerization is detected by the measurement of small transient currents arising from ion diffusion during polymerization. A transimpedance amplifier is used to detect these small currents; we implemented a twenty-four channel recording system on a single printed circuit board. Various contributions to the input-referred current noise are analyzed and characterized, as it limits the minimum detectable current and thus the biological limit of detection. We obtained 8.5 pA RMS mean noise current (averaged over all 24 channels) over the recording bandwidth (DC to 2 kHz). With digital filtering, the input-referred current noise of the acquisition system is reduced to 2.4 pA, which is much lower than the biological noise. Electrical crosstalk between channels is measured, and a model for the crosstalk is presented. Minimizing the crosstalk is critical because it can lead to erroneous microarray data. With proper precautions, crosstalk is reduced to a negligible value (less than 1.4%). Using a micro-fabricated array of 24 gold electrodes, we demonstrated system functionality by detecting the presence of a target DNA oligonucleotide which hybridized onto its corresponding target.

  10. A novel ECG detector performance metric and its relationship with missing and false heart rate limit alarms.

    PubMed

    Daluwatte, Chathuri; Vicente, Jose; Galeotti, Loriano; Johannesen, Lars; Strauss, David G; Scully, Christopher G

    Performance of ECG beat detectors is traditionally assessed on long intervals (e.g.: 30min), but only incorrect detections within a short interval (e.g.: 10s) may cause incorrect (i.e., missed+false) heart rate limit alarms (tachycardia and bradycardia). We propose a novel performance metric based on distribution of incorrect beat detection over a short interval and assess its relationship with incorrect heart rate limit alarm rates. Six ECG beat detectors were assessed using performance metrics over long interval (sensitivity and positive predictive value over 30min) and short interval (Area Under empirical cumulative distribution function (AUecdf) for short interval (i.e., 10s) sensitivity and positive predictive value) on two ECG databases. False heart rate limit and asystole alarm rates calculated using a third ECG database were then correlated (Spearman's rank correlation) with each calculated performance metric. False alarm rates correlated with sensitivity calculated on long interval (i.e., 30min) (ρ=-0.8 and p<0.05) and AUecdf for sensitivity (ρ=0.9 and p<0.05) in all assessed ECG databases. Sensitivity over 30min grouped the two detectors with lowest false alarm rates while AUecdf for sensitivity provided further information to identify the two beat detectors with highest false alarm rates as well, which was inseparable with sensitivity over 30min. Short interval performance metrics can provide insights on the potential of a beat detector to generate incorrect heart rate limit alarms. Published by Elsevier Inc.

  11. Fast methods for analysis of neurotransmitters from single cell and monitoring their releases in central nervous system by capillary electrophoresis, fluorescence microscopy and luminescence imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Ziqiang

    1999-12-10

    Fast methods for separation and detection of important neurotransmitters and the releases in central nervous system (CNS) were developed. Enzyme based immunoassay combined with capillary electrophoresis was used to analyze the contents of amino acid neurotransmitters from single neuron cells. The release of amino acid neurotransmitters from neuron cultures was monitored by laser induced fluorescence imaging method. The release and signal transduction of adenosine triphosphate (ATP) in CNS was studied with sensitive luminescence imaging method. A new dual-enzyme on-column reaction method combined with capillary electrophoresis has been developed for determining the glutamate content in single cells. Detection was based onmore » monitoring the laser-induced fluorescence of the reaction product NADH, and the measured fluorescence intensity was related to the concentration of glutamate in each cell. The detection limit of glutamate is down to 10 -8 M level, which is 1 order of magnitude lower than the previously reported detection limit based on similar detection methods. The mass detection limit of a few attomoles is far superior to that of any other reports. Selectivity for glutamate is excellent over most of amino acids. The glutamate content in single human erythrocyte and baby rat brain neurons were determined with this method and results agreed well with literature values.« less

  12. [Usefulness of ¹⁸F-fluoro-2-deoxyglucose positron emission tomography in evaluation of gastric cancer stage].

    PubMed

    Yoon, Na Ri; Park, Jae Myung; Jung, Hee Sun; Cho, Yu Kyung; Lee, In Seok; Choi, Myung Gyu; Chung, In Sik; Song, Kyo Young; Park, Cho Hyun

    2012-05-01

    The usefulness of ¹⁸F-fluoro-2-deoxyglucose (FDG)-PET in detecting primary cancer, lymph node metastasis, and distant metastasis were studied in the gastric cancer patients. The subjects were 392 gastric cancer patients who received FDG-PET and an abdominal CT test prior to surgery. The results of FDG-PET and CT were compared with the surgical and pathologic results. The primary site detection rate of FDG-PET was 74.4%, 50.3% in early gastric cancer and 92.0% in advanced gastric cancer. Detection rate was higher when tumors were larger than 3.5 cm, had deeper depth of invasion, and at a later stage (p<0.05, respectively). In multivariate analysis, tumor size, spread of tumor cells beyond the muscle layer (≥T2), and lymph node metastasis were statistically significant factors in primary site detection rate. The sensitivity, specificity, and positive predictive value of FDG-PET to lymph node metastasis were 59.6%, 88.8%, and 81.1% respectively, sensitivity being lower compared to CT while specificity and positive predictive value were higher. Sensitivity, specificity, and positive predictive value to distant metastasis were, respectively, 66.7%, 99.2%, and 88.0%, similar to CT. In 21 of the 392 patients (5.4%), synchronous double primary cancers were detected. In gastric cancer, usefullness of FDG-PET is limited to the advanced stage. Diagnostic value of this test was not superior to CT. However, FDG-PET may be useful in detecting synchronous double primary cancers.

  13. Label-Free Aptasensor for Lysozyme Detection Using Electrochemical Impedance Spectroscopy.

    PubMed

    Ortiz-Aguayo, Dionisia; Del Valle, Manel

    2018-01-26

    This research develops a label-free aptamer biosensor (aptasensor) based on graphite-epoxy composite electrodes (GECs) for the detection of lysozyme protein using Electrochemical Impedance Spectroscopy (EIS) technique. The chosen immobilization technique was based on covalent bonding using carbodiimide chemistry; for this purpose, carboxylic moieties were first generated on the graphite by electrochemical grafting. The detection was performed using [Fe(CN)₆] 3- /[Fe(CN)₆] 4- as redox probe. After recording the frequency response, values were fitted to its electric model using the principle of equivalent circuits. The aptasensor showed a linear response up to 5 µM for lysozyme and a limit of detection of 1.67 µM. The sensitivity of the established method was 0.090 µM -1 in relative charge transfer resistance values. The interference response by main proteins, such as bovine serum albumin and cytochrome c, has been also characterized. To finally verify the performance of the developed aptasensor, it was applied to wine analysis.

  14. Label-Free Aptasensor for Lysozyme Detection Using Electrochemical Impedance Spectroscopy

    PubMed Central

    2018-01-01

    This research develops a label-free aptamer biosensor (aptasensor) based on graphite-epoxy composite electrodes (GECs) for the detection of lysozyme protein using Electrochemical Impedance Spectroscopy (EIS) technique. The chosen immobilization technique was based on covalent bonding using carbodiimide chemistry; for this purpose, carboxylic moieties were first generated on the graphite by electrochemical grafting. The detection was performed using [Fe(CN)6]3−/[Fe(CN)6]4− as redox probe. After recording the frequency response, values were fitted to its electric model using the principle of equivalent circuits. The aptasensor showed a linear response up to 5 µM for lysozyme and a limit of detection of 1.67 µM. The sensitivity of the established method was 0.090 µM−1 in relative charge transfer resistance values. The interference response by main proteins, such as bovine serum albumin and cytochrome c, has been also characterized. To finally verify the performance of the developed aptasensor, it was applied to wine analysis. PMID:29373502

  15. SU-E-T-144: Effective Analysis of VMAT QA Generated Trajectory Log Files for Medical Accelerator Predictive Maintenance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Able, CM; Baydush, AH; Nguyen, C

    Purpose: To determine the effectiveness of SPC analysis for a model predictive maintenance process that uses accelerator generated parameter and performance data contained in trajectory log files. Methods: Each trajectory file is decoded and a total of 131 axes positions are recorded (collimator jaw position, gantry angle, each MLC, etc.). This raw data is processed and either axis positions are extracted at critical points during the delivery or positional change over time is used to determine axis velocity. The focus of our analysis is the accuracy, reproducibility and fidelity of each axis. A reference positional trace of the gantry andmore » each MLC is used as a motion baseline for cross correlation (CC) analysis. A total of 494 parameters (482 MLC related) were analyzed using Individual and Moving Range (I/MR) charts. The chart limits were calculated using a hybrid technique that included the use of the standard 3σ limits and parameter/system specifications. Synthetic errors/changes were introduced to determine the initial effectiveness of I/MR charts in detecting relevant changes in operating parameters. The magnitude of the synthetic errors/changes was based on: TG-142 and published analysis of VMAT delivery accuracy. Results: All errors introduced were detected. Synthetic positional errors of 2mm for collimator jaw and MLC carriage exceeded the chart limits. Gantry speed and each MLC speed are analyzed at two different points in the delivery. Simulated Gantry speed error (0.2 deg/sec) and MLC speed error (0.1 cm/sec) exceeded the speed chart limits. Gantry position error of 0.2 deg was detected by the CC maximum value charts. The MLC position error of 0.1 cm was detected by the CC maximum value location charts for every MLC. Conclusion: SPC I/MR evaluation of trajectory log file parameters may be effective in providing an early warning of performance degradation or component failure for medical accelerator systems.« less

  16. Thermodynamic framework to assess low abundance DNA mutation detection by hybridization

    PubMed Central

    Willems, Hanny; Jacobs, An; Hadiwikarta, Wahyu Wijaya; Venken, Tom; Valkenborg, Dirk; Van Roy, Nadine; Vandesompele, Jo; Hooyberghs, Jef

    2017-01-01

    The knowledge of genomic DNA variations in patient samples has a high and increasing value for human diagnostics in its broadest sense. Although many methods and sensors to detect or quantify these variations are available or under development, the number of underlying physico-chemical detection principles is limited. One of these principles is the hybridization of sample target DNA versus nucleic acid probes. We introduce a novel thermodynamics approach and develop a framework to exploit the specific detection capabilities of nucleic acid hybridization, using generic principles applicable to any platform. As a case study, we detect point mutations in the KRAS oncogene on a microarray platform. For the given platform and hybridization conditions, we demonstrate the multiplex detection capability of hybridization and assess the detection limit using thermodynamic considerations; DNA containing point mutations in a background of wild type sequences can be identified down to at least 1% relative concentration. In order to show the clinical relevance, the detection capabilities are confirmed on challenging formalin-fixed paraffin-embedded clinical tumor samples. This enzyme-free detection framework contains the accuracy and efficiency to screen for hundreds of mutations in a single run with many potential applications in molecular diagnostics and the field of personalised medicine. PMID:28542229

  17. Catalytic spectrophotometric determination of iodine in coal by pyrohydrolysis decomposition.

    PubMed

    Wu, Daishe; Deng, Haiwen; Wang, Wuyi; Xiao, Huayun

    2007-10-10

    A method for the determination of iodine in coal using pyrohydrolysis for sample decomposition was proposed. A pyrohydrolysis apparatus system was constructed, and the procedure was designed to burn and hydrolyse coal steadily and completely. The parameters of pyrohydrolysis were optimized through the orthogonal experimental design. Iodine in the absorption solution was evaluated by the catalytic spectrophotometric method, and the absorbance at 420 nm was measured by a double-beam UV-visible spectrophotometer. The limit of detection and quantification of the proposed method were 0.09 microg g(-1) and 0.29 microg g(-1), respectively. After analysing some Chinese soil reference materials (SRMs), a reasonable agreement was found between the measured values and the certified values. The accuracy of this approach was confirmed by the analysis of eight coals spiked with SRMs with an indexed recovery from 94.97 to 109.56%, whose mean value was 102.58%. Six repeated tests were conducted for eight coal samples, including high sulfur coal and high fluorine coal. A good repeatability was obtained with a relative standard deviation value from 2.88 to 9.52%, averaging 5.87%. With such benefits as simplicity, precision, accuracy and economy, this approach can meet the requirements of the limits of detection and quantification for analysing iodine in coal, and hence it is highly suitable for routine analysis.

  18. Determination of aflatoxin B1 levels in organic spices and herbs.

    PubMed

    Tosun, Halil; Arslan, Recep

    2013-01-01

    Organically produced spices and herbs were analyzed for determination of aflatoxin B1 (AFB1) by ELISA using immunoaffinity column. For this purpose 93 organic spices and 37 organic herbs were randomly selected from organic markets and organic shops in Turkey. AFB1 was detected in 58 organic spice and 32 organic herb samples. Among organic spice samples, the maximum value was detected in cinnamon sample (53 μg/kg). AFB1 was not detected in thyme samples. AFB1 levels of 41 organic spice samples were above the EU regulatory limit (5 μg/kg). Among organic herb samples the highest concentration of AFB1 (52.5 μg/kg) was detected in a rosehip sample. AFB1 levels of 21 organic herb samples were above the regulatory limits of the European Union. These results showed that more stringent measures must be taken for the prevention of mold contamination in the production of organic spices and herbs.

  19. Determination of Aflatoxin B1 Levels in Organic Spices and Herbs

    PubMed Central

    Tosun, Halil; Arslan, Recep

    2013-01-01

    Organically produced spices and herbs were analyzed for determination of aflatoxin B1 (AFB1) by ELISA using immunoaffinity column. For this purpose 93 organic spices and 37 organic herbs were randomly selected from organic markets and organic shops in Turkey. AFB1 was detected in 58 organic spice and 32 organic herb samples. Among organic spice samples, the maximum value was detected in cinnamon sample (53 μg/kg). AFB1 was not detected in thyme samples. AFB1 levels of 41 organic spice samples were above the EU regulatory limit (5 μg/kg). Among organic herb samples the highest concentration of AFB1 (52.5 μg/kg) was detected in a rosehip sample. AFB1 levels of 21 organic herb samples were above the regulatory limits of the European Union. These results showed that more stringent measures must be taken for the prevention of mold contamination in the production of organic spices and herbs. PMID:23766719

  20. Direct liquid chromatography method for the simultaneous quantification of hydroxytyrosol and tyrosol in red wines.

    PubMed

    Piñeiro, Zulema; Cantos-Villar, Emma; Palma, Miguel; Puertas, Belen

    2011-11-09

    A validated HPLC method with fluorescence detection for the simultaneous quantification of hydroxytyrosol and tyrosol in red wines is described. Detection conditions for both compounds were optimized (excitation at 279 and 278 and emission at 631 and 598 nm for hydroxytyrosol and tyrosol, respectively). The validation of the analytical method was based on selectivity, linearity, robustness, detection and quantification limits, repeatability, and recovery. The detection and quantification limits in red wines were set at 0.023 and 0.076 mg L(-1) for hydroxytyrosol and at 0.007 and 0.024 mg L(-1) for tyrosol determination, respectively. Precision values, both within-day and between-day (n = 5), remained below 3% for both compounds. In addition, a fractional factorial experimental design was developed to analyze the influence of six different conditions on analysis. The final optimized HPLC-fluorescence method allowed the analysis of 30 nonpretreated Spanish red wines to evaluate their hydroxytyrosol and tyrosol contents.

  1. A chromogenic and fluorogenic rhodol-based chemosensor for hydrazine detection and its application in live cell bioimaging

    NASA Astrophysics Data System (ADS)

    Tiensomjitr, Khomsan; Noorat, Rattha; Chomngam, Sinchai; Wechakorn, Kanokorn; Prabpai, Samran; Kanjanasirirat, Phongthon; Pewkliang, Yongyut; Borwornpinyo, Suparerk; Kongsaeree, Palangpon

    2018-04-01

    A rhodol-based fluorescent probe has been developed as a selective hydrazine chemosensor using levulinate as a recognition site. The rhodol levulinate probe (RL) demonstrated high selectivity and sensitivity toward hydrazine among other molecules. The chromogenic response of RL solution to hydrazine from colorless to pink could be readily observed by the naked eye, while strong fluorescence emission could be monitored upon excitation at 525 nm. The detection process occurred via a ring-opening process of the spirolactone initiated by hydrazinolysis, triggering the fluorescence emission with a 53-fold enhancement. The probe rapidly reacted with hydrazine in aqueous medium with the detection limit of 26 nM (0.83 ppb), lower than the threshold limit value (TLV) of 10 ppb suggested by the U.S. Environmental Protection Agency. Furthermore, RL-impregnated paper strips could detect hydrazine vapor. For biological applicability of RL, its membrane-permeable property led to bioimaging of hydrazine in live HepG2 cells by confocal fluorescence microscopy.

  2. 40 CFR 141.719 - Additional filtration toolbox components.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... establish a quality control release value (QCRV) for a non-destructive performance test that demonstrates... Detection Limit) (5) Challenge testing must be conducted at the maximum design flow rate for the filter as... representative hydraulic conditions at the maximum design flux and maximum design process recovery specified by...

  3. 40 CFR 141.719 - Additional filtration toolbox components.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... establish a quality control release value (QCRV) for a non-destructive performance test that demonstrates... Detection Limit) (5) Challenge testing must be conducted at the maximum design flow rate for the filter as... representative hydraulic conditions at the maximum design flux and maximum design process recovery specified by...

  4. 40 CFR 63.861 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... CFR part 60, appendix A) and with all nondetect data treated as one-half of the method detection limit... PM emissions. Nondetect data means, for the purposes of this subpart, any value that is below the...-Pacific's facility in Big Island, Virginia only, the end of the gasification system commissioning phase...

  5. 40 CFR 63.861 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... CFR part 60, appendix A) and with all nondetect data treated as one-half of the method detection limit... PM emissions. Nondetect data means, for the purposes of this subpart, any value that is below the...-Pacific's facility in Big Island, Virginia only, the end of the gasification system commissioning phase...

  6. 40 CFR 63.861 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... CFR part 60, appendix A) and with all nondetect data treated as one-half of the method detection limit... PM emissions. Nondetect data means, for the purposes of this subpart, any value that is below the...-Pacific's facility in Big Island, Virginia only, the end of the gasification system commissioning phase...

  7. Real-time failure control (SAFD)

    NASA Technical Reports Server (NTRS)

    Panossian, Hagop V.; Kemp, Victoria R.; Eckerling, Sherry J.

    1990-01-01

    The Real Time Failure Control program involves development of a failure detection algorithm, referred as System for Failure and Anomaly Detection (SAFD), for the Space Shuttle Main Engine (SSME). This failure detection approach is signal-based and it entails monitoring SSME measurement signals based on predetermined and computed mean values and standard deviations. Twenty four engine measurements are included in the algorithm and provisions are made to add more parameters if needed. Six major sections of research are presented: (1) SAFD algorithm development; (2) SAFD simulations; (3) Digital Transient Model failure simulation; (4) closed-loop simulation; (5) SAFD current limitations; and (6) enhancements planned for.

  8. Validation of a Thin-Layer Chromatography for the Determination of Hydrocortisone Acetate and Lidocaine in a Pharmaceutical Preparation

    PubMed Central

    Dołowy, Małgorzata; Kulpińska-Kucia, Katarzyna; Pyka, Alina

    2014-01-01

    A new specific, precise, accurate, and robust TLC-densitometry has been developed for the simultaneous determination of hydrocortisone acetate and lidocaine hydrochloride in combined pharmaceutical formulation. The chromatographic analysis was carried out using a mobile phase consisting of chloroform + acetone + ammonia (25%) in volume composition 8 : 2 : 0.1 and silica gel 60F254 plates. Densitometric detection was performed in UV at wavelengths 200 nm and 250 nm, respectively, for lidocaine hydrochloride and hydrocortisone acetate. The validation of the proposed method was performed in terms of specificity, linearity, limit of detection (LOD), limit of quantification (LOQ), precision, accuracy, and robustness. The applied TLC procedure is linear in hydrocortisone acetate concentration range of 3.75 ÷ 12.50 μg·spot−1, and from 1.00 ÷ 2.50 μg·spot−1 for lidocaine hydrochloride. The developed method was found to be accurate (the value of the coefficient of variation CV [%] is less than 3%), precise (CV [%] is less than 2%), specific, and robust. LOQ of hydrocortisone acetate is 0.198 μg·spot−1 and LOD is 0.066 μg·spot−1. LOQ and LOD values for lidocaine hydrochloride are 0.270 and 0.090 μg·spot−1, respectively. The assay value of both bioactive substances is consistent with the limits recommended by Pharmacopoeia. PMID:24526880

  9. Validation of a thin-layer chromatography for the determination of hydrocortisone acetate and lidocaine in a pharmaceutical preparation.

    PubMed

    Dołowy, Małgorzata; Kulpińska-Kucia, Katarzyna; Pyka, Alina

    2014-01-01

    A new specific, precise, accurate, and robust TLC-densitometry has been developed for the simultaneous determination of hydrocortisone acetate and lidocaine hydrochloride in combined pharmaceutical formulation. The chromatographic analysis was carried out using a mobile phase consisting of chloroform+acetone+ammonia (25%) in volume composition 8:2:0.1 and silica gel 60F254 plates. Densitometric detection was performed in UV at wavelengths 200 nm and 250 nm, respectively, for lidocaine hydrochloride and hydrocortisone acetate. The validation of the proposed method was performed in terms of specificity, linearity, limit of detection (LOD), limit of quantification (LOQ), precision, accuracy, and robustness. The applied TLC procedure is linear in hydrocortisone acetate concentration range of 3.75÷12.50  μg·spot(-1), and from 1.00÷2.50  μg·spot(-1) for lidocaine hydrochloride. The developed method was found to be accurate (the value of the coefficient of variation CV [%] is less than 3%), precise (CV [%] is less than 2%), specific, and robust. LOQ of hydrocortisone acetate is 0.198  μg·spot(-1) and LOD is 0.066  μg·spot(-1). LOQ and LOD values for lidocaine hydrochloride are 0.270 and 0.090  μg·spot(-1), respectively. The assay value of both bioactive substances is consistent with the limits recommended by Pharmacopoeia.

  10. Development of a GC/C/IRMS method--confirmation of a novel steroid profiling approach in doping control.

    PubMed

    Van Renterghem, Pieter; Polet, Michael; Brooker, Lance; Van Gansbeke, Wim; Van Eenoo, Peter

    2012-09-01

    In doping control, an athlete can only be convicted with the misuse with endogenous steroids like testosterone (T), if abnormal values of steroid metabolites and steroid ratios are observed and if the subsequent analysis with isotope ratios mass spectrometry (IRMS) confirms the presence of exogenously administered androgens. In this work, we compare the results of a novel steroid profiling approach with the performance an in-house developed IRMS method. The developed IRMS has the advantage over other methods to be relatively short in time and with target compounds androsterone, etiocholanolone, 5β-androstane 3α,17β-diol and 5α-androstane 3α,17β-diol. Pregnanediol was used as an endogenous reference compound (ERC). Reference limits for the IRMS values were established and applied as decision limits for the evaluation of excretion urine from administration with oral T, T-gel, dihydrotestosterone (DHT) - gel and dehydroepiandrosterone (DHEA). Results indicated the importance of both androstanediols as important IRMS markers where relative values compared to an ERC (Δδ(13)C) yielded better detection accuracy than absolute δ(13)C-values. The detection times of all administered endogenous steroids were evaluated using the proposed thresholds. The results of traditional steroid profiling and a new approach based upon minor steroid metabolites monitoring introduced in a longitudinal framework were evaluated with IRMS. With traditional steroid profiling methods, 95% of the atypical samples could be confirmed whereas an additional 74% of IRMS confirmed was provided by a new biomarkers strategy. These results prove that the other steroid profiling strategies can improve the efficiency in detection of misuse with endogenous steroids. Copyright © 2012 Elsevier Inc. All rights reserved.

  11. Experimental Constraints on He, Ne, Ar Behavior at Mantle Conditions

    NASA Astrophysics Data System (ADS)

    Jackson, C.; Kelley, S. P.; Parman, S. W.; Cooper, R. F.

    2010-12-01

    We have experimentally constrained He, Ne and Ar mineral-melt partitioning for olivine, enstatite and spinel under mantle P-T conditions. The experiments were run in a piston cylinder apparatus. Run products were analyzed by UV laser ablation microprobe (UVLAMP). Our data (Ol, Opx, Sp), along with literature data (Cpx), suggest He, Ne and Ar are incompatible during mantle melting. Gem quality crystals of En100, Sp and Fo90 were polished using colloidal silica and loaded along with a MgO rich, synthetic MORB powder into a graphite inner and Pt outer capsule. Within the inner capsule, crystals were faced against graphite, an identical crystal or polished glassy carbon. Equal pressures (40-60 total bars) of He, Ne and Ar were loaded into the outer capsule before it was welded closed. The run conditions were 1450C and 1-2 GPa for 10 hrs (Brown University). Depth profiles of the mineral faces were obtained using a 193 nm excimer laser (Open University). The large crystal area and short wavelength laser allows for measurements with high depth resolution and concentration precision: a 400 um aperture with 150 nm ablation depth can provide a detection limit (3 sigma > blank) of ~500 ppb He, ~1 ppm Ne and ~500 ppb Ar. Three mineral ablation pits were imaged using a white light interferometer at Tufts University and indicate an ablation rate of ~25 nm/pulse. Glass ablation rates are estimated using previous measurements. The melts were generally understaturated with respect to He, Ne and Ar (1-10, 3-200 and 4-1000 PPM, respectively). Concentrations in the minerals were mostly below detection limits. Where detectable, near surface gas concentrations visually correlate with the amount of adhering graphite. This could be due to trapped/adsorbed gas in the graphite or to surface deformation produced by the graphite. The surface with the least adhering graphite and smoothest surface (faced against glassy carbon) shows no observable near surface enrichment of He, Ne or Ar. Given our low detection limits, the data suggest that the high solubility, slow diffusion pathway observed by Watson et al (2007) may not operate at mantle conditions. We assume the areas least affected by graphite (lowest concentrations) place the best constraints on the partitioning values (K= [min]/[melt]). Where concentrations were below detection limits, we used the detection limits as upper bounds on the concentrations to constrain K values: He-KEn100<0.1, KSp<0.01, KFo90<0.005 Ne-KEn100<0.1, KSp<0.01, KFo90<0.005 Ar-KEn100<0.1, KSp<0.01, KFo90<0.0005 These values are consistent with previous studies at low pressure (Heber et al 2007, Parman et al 2005). VS Heber, RA Brooker, SP Kelley, BJ Wood; GCA; 2007 SW Parman, MD Kurz, SH Hart, TL Grove, Nature, 2005 EB Watson, JB Thomas, DJ Cherniak , Nature, 2007

  12. Group-focused morality is associated with limited conflict detection and resolution capacity: Neuroanatomical evidence.

    PubMed

    Nash, Kyle; Baumgartner, Thomas; Knoch, Daria

    2017-02-01

    Group-focused moral foundations (GMFs) - moral values that help protect the group's welfare - sharply divide conservatives from liberals and religiously devout from non-believers. However, there is little evidence about what drives this divide. Moral foundations theory and the model of motivated social cognition both associate group-focused moral foundations with differences in conflict detection and resolution capacity, but in opposing directions. Individual differences in conflict detection and resolution implicate specific neuroanatomical differences. Examining neuroanatomy thus affords an objective and non-biased opportunity to contrast these influential theories. Here, we report that increased adherence to group-focused moral foundations was strongly associated (whole-brain corrected) with reduced gray matter volume in key regions of the conflict detection and resolution system (anterior cingulate cortex and lateral prefrontal cortex). Because reduced gray matter is reliably associated with reduced neural and cognitive capacity, these findings support the idea outlined in the model of motivated social cognition that belief in group-focused moral values is associated with reduced conflict detection and resolution capacity. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Electrochemical sensor for hazardous food colourant quinoline yellow based on carbon nanotube-modified electrode.

    PubMed

    Zhao, Jun; Zhang, Yu; Wu, Kangbing; Chen, Jianwei; Zhou, Yikai

    2011-09-15

    A novel electrochemical method using multi-wall carbon nanotube (MWNT) film-modified electrode was developed for the detection of quinoline yellow. In pH 8 phosphate buffer, an irreversible oxidation peak at 0.71V was observed for quinoline yellow. Compared with the unmodified electrode, the MWNT film-modified electrode greatly increases the oxidation peak current of quinoline yellow, showing notable enhancement effect. The effects of pH value, amount of MWNT, accumulation potential and time were studied on the oxidation peak current of quinoline yellow. The linear range is from 0.75 to 20mgL(-1), and the limit of detection is 0.5mgL(-1). It was applied to the detection of quinoline yellow in commercial soft drinks, and the results consisted with the value that obtained by high-performance liquid chromatography. Copyright © 2011 Elsevier Ltd. All rights reserved.

  14. Self-referenced single-shot THz detection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Russell, Brandon K.; Ofori-Okai, Benjamin K.; Chen, Zhijiang

    We demonstrate a self-referencing method to reduce noise in a single-shot terahertz detection scheme. By splitting a single terahertz pulse and using a reflective echelon, both the signal and reference terahertz time-domain waveforms were measured using one laser pulse. Simultaneous acquisition of these waveforms significantly reduces noise originating from shot-to-shot fluctuations. Here, we show that correlation function based referencing, which is not limited to polarization dependent measurements, can achieve a noise floor that is comparable to state-of-the-art polarization-gated balanced detection. Lastly, we extract the DC conductivity of a 30 nm free-standing gold film using a single THz pulse. The measuredmore » value of σ 0 = 1.3 ± 0.4 × 10 7 S m -1 is in good agreement with the value measured by four-point probe, indicating the viability of this method for measuring dynamical changes and small signals.« less

  15. Self-referenced single-shot THz detection

    DOE PAGES

    Russell, Brandon K.; Ofori-Okai, Benjamin K.; Chen, Zhijiang; ...

    2017-06-29

    We demonstrate a self-referencing method to reduce noise in a single-shot terahertz detection scheme. By splitting a single terahertz pulse and using a reflective echelon, both the signal and reference terahertz time-domain waveforms were measured using one laser pulse. Simultaneous acquisition of these waveforms significantly reduces noise originating from shot-to-shot fluctuations. Here, we show that correlation function based referencing, which is not limited to polarization dependent measurements, can achieve a noise floor that is comparable to state-of-the-art polarization-gated balanced detection. Lastly, we extract the DC conductivity of a 30 nm free-standing gold film using a single THz pulse. The measuredmore » value of σ 0 = 1.3 ± 0.4 × 10 7 S m -1 is in good agreement with the value measured by four-point probe, indicating the viability of this method for measuring dynamical changes and small signals.« less

  16. Development of a lab-on-chip electrochemical immunosensor for detection of Polycyclic Aromatic Hydrocarbons (PAH) in environmental water

    NASA Astrophysics Data System (ADS)

    Felemban, Shifa; Vazquez, Patricia; Dehnert, Jan; Goridko, Vadim; Tijero, Maria; Moore, Eric

    2017-06-01

    The work described in this manuscript focuses on how the integration of immunoassay techniques in combination with electrochemical detection can provide a portable and very accurate solution for detection of water pollutants that are detrimental for human health. In particular, we focus our work on the quantification of polycyclic aromatic hydrocarbons (PAHs) in polluted water. Our integrative approach facilitates a real-time detection of this family of organic compounds, by reducing the time of analysis to less than one hour. Additionally, the use of a lab-on-a-chip platform delivers a portable solution that could be used in situ. Optimization of a displacement assay that investigates the presence and concentration of Benzo[a]pyrene in water, allows with the miniaturization of the standard ELISA format into a highly accurate system that provides fast results. The limits of detection obtained are comparable to those of available state-of-the art tools, and achieve the values set by European Drinking Water Directive, 0.10ng/l, as the limit for PAHs in drinking water.

  17. Algorithm for parametric community detection in networks.

    PubMed

    Bettinelli, Andrea; Hansen, Pierre; Liberti, Leo

    2012-07-01

    Modularity maximization is extensively used to detect communities in complex networks. It has been shown, however, that this method suffers from a resolution limit: Small communities may be undetectable in the presence of larger ones even if they are very dense. To alleviate this defect, various modifications of the modularity function have been proposed as well as multiresolution methods. In this paper we systematically study a simple model (proposed by Pons and Latapy [Theor. Comput. Sci. 412, 892 (2011)] and similar to the parametric model of Reichardt and Bornholdt [Phys. Rev. E 74, 016110 (2006)]) with a single parameter α that balances the fraction of within community edges and the expected fraction of edges according to the configuration model. An exact algorithm is proposed to find optimal solutions for all values of α as well as the corresponding successive intervals of α values for which they are optimal. This algorithm relies upon a routine for exact modularity maximization and is limited to moderate size instances. An agglomerative hierarchical heuristic is therefore proposed to address parametric modularity detection in large networks. At each iteration the smallest value of α for which it is worthwhile to merge two communities of the current partition is found. Then merging is performed and the data are updated accordingly. An implementation is proposed with the same time and space complexity as the well-known Clauset-Newman-Moore (CNM) heuristic [Phys. Rev. E 70, 066111 (2004)]. Experimental results on artificial and real world problems show that (i) communities are detected by both exact and heuristic methods for all values of the parameter α; (ii) the dendrogram summarizing the results of the heuristic method provides a useful tool for substantive analysis, as illustrated particularly on a Les Misérables data set; (iii) the difference between the parametric modularity values given by the exact method and those given by the heuristic is moderate; (iv) the heuristic version of the proposed parametric method, viewed as a modularity maximization tool, gives better results than the CNM heuristic for large instances.

  18. Technical note: False low turbidity readings from optical probes during high suspended-sediment concentrations

    NASA Astrophysics Data System (ADS)

    Voichick, Nicholas; Topping, David J.; Griffiths, Ronald E.

    2018-03-01

    Turbidity, a measure of water clarity, is monitored for a variety of purposes including (1) to help determine whether water is safe to drink, (2) to establish background conditions of lakes and rivers and detect pollution caused by construction projects and stormwater discharge, (3) to study sediment transport in rivers and erosion in catchments, (4) to manage siltation of water reservoirs, and (5) to establish connections with aquatic biological properties, such as primary production and predator-prey interactions. Turbidity is typically measured with an optical probe that detects light scattered from particles in the water. Probes have defined upper limits of the range of turbidity that they can measure. The general assumption is that when turbidity exceeds this upper limit, the values of turbidity will be constant, i.e., the probe is pegged; however, this assumption is not necessarily valid. In rivers with limited variation in the physical properties of the suspended sediment, at lower suspended-sediment concentrations, an increase in suspended-sediment concentration will cause a linear increase in turbidity. When the suspended-sediment concentration in these rivers is high, turbidity levels can exceed the upper measurement limit of an optical probe and record a constant pegged value. However, at extremely high suspended-sediment concentrations, optical turbidity probes do not necessarily stay pegged at a constant value. Data from the Colorado River in Grand Canyon, Arizona, USA, and a laboratory experiment both demonstrate that when turbidity exceeds instrument-pegged conditions, increasing suspended-sediment concentration (and thus increasing turbidity) may cause optical probes to record decreasing false turbidity values that appear to be within the valid measurement range of the probe. Therefore, under high-turbidity conditions, other surrogate measurements of turbidity (e.g., acoustic-attenuation measurements or suspended-sediment samples) are necessary to correct these low false turbidity measurements and accurately measure turbidity.

  19. Technical note: False low turbidity readings from optical probes during high suspended-sediment concentrations

    USGS Publications Warehouse

    Voichick, Nicholas; Topping, David; Griffiths, Ronald

    2018-01-01

    Turbidity, a measure of water clarity, is monitored for a variety of purposes including (1) to help determine whether water is safe to drink, (2) to establish background conditions of lakes and rivers and detect pollution caused by construction projects and stormwater discharge, (3) to study sediment transport in rivers and erosion in catchments, (4) to manage siltation of water reservoirs, and (5) to establish connections with aquatic biological properties, such as primary production and predator–prey interactions. Turbidity is typically measured with an optical probe that detects light scattered from particles in the water. Probes have defined upper limits of the range of turbidity that they can measure. The general assumption is that when turbidity exceeds this upper limit, the values of turbidity will be constant, i.e., the probe is pegged; however, this assumption is not necessarily valid. In rivers with limited variation in the physical properties of the suspended sediment, at lower suspended-sediment concentrations, an increase in suspended-sediment concentration will cause a linear increase in turbidity. When the suspended-sediment concentration in these rivers is high, turbidity levels can exceed the upper measurement limit of an optical probe and record a constant pegged value. However, at extremely high suspended-sediment concentrations, optical turbidity probes do not necessarily stay pegged at a constant value. Data from the Colorado River in Grand Canyon, Arizona, USA, and a laboratory experiment both demonstrate that when turbidity exceeds instrument-pegged conditions, increasing suspended-sediment concentration (and thus increasing turbidity) may cause optical probes to record decreasing false turbidity values that appear to be within the valid measurement range of the probe. Therefore, under high-turbidity conditions, other surrogate measurements of turbidity (e.g., acoustic-attenuation measurements or suspended-sediment samples) are necessary to correct these low false turbidity measurements and accurately measure turbidity.

  20. Using Hashimoto thyroiditis as gold standard to determine the upper limit value of thyroid stimulating hormone in a Chinese cohort.

    PubMed

    Li, Yu; Chen, Dong-Ning; Cui, Jing; Xin, Zhong; Yang, Guang-Ran; Niu, Ming-Jia; Yang, Jin-Kui

    2016-11-06

    Subclinical hypothyroidism, commonly caused by Hashimoto thyroiditis (HT), is a risk factor for cardiovascular diseases. This disorder is defined as merely having elevated serum thyroid stimulating hormone (TSH) levels. However, the upper limit of reference range for TSH is debated recently. This study was to determine the cutoff value for the upper normal limit of TSH in a cohort using the prevalence of Hashimoto thyroiditis as "gold" calibration standard. The research population was medical staff of 2856 individuals who took part in health examination annually. Serum free triiodothyronine (FT3), free thyroxine (FT4), TSH, thyroid peroxidase antibody (TPAb), thyroglobulin antibody (TGAb) and other biochemistry parameters were tested. Meanwhile, thyroid ultrasound examination was performed. The diagnosis of HT was based on presence of thyroid antibodies (TPAb and TGAb) and abnormalities of thyroid ultrasound examination. We used two different methods to estimate the cutoff point of TSH based on the prevalence of HT. Joinpoint regression showed the prevalence of HT increased significantly at the ninth decile of TSH value corresponding to 2.9 mU/L. ROC curve showed a TSH cutoff value of 2.6 mU/L with the maximized sensitivity and specificity in identifying HT. Using the newly defined cutoff value of TSH can detect patients with hyperlipidemia more efficiently, which may indicate our approach to define the upper limit of TSH can make more sense from the clinical point of view. A significant increase in the prevalence of HT occurred among individuals with a TSH of 2.6-2.9 mU/L made it possible to determine the cutoff value of normal upper limit of TSH.

  1. Quality control of test iodine in urine by spectrophotometry UV-Vis

    NASA Astrophysics Data System (ADS)

    Huda, Thorikul; Nafisah, Durotun; Kumorowulan, Suryati; Lestari, Sri

    2017-12-01

    A quality control of iodine test in with UV-Vis spectrophotometry has been done. The purpose of this research is to find out whether the test results of samples conducted by Clinical Office of Research and Development Of GAKI (BP2GAKI) laboratory are still controlled, feasible and reliable, and still consistent over time, as indicated by the control chart. Quality control parameters are linearity, precision, accuracy, limit of detection, and limit of quantification. Based on the quality control that has been done, obtained linearity (r)= -0.9974, the detection limit and the limit of quantitation are respectively 2.26 µg/L and 7.54 µg/L, while the accuracy is calculated by %recovery and precision with value % RSD are 97.4161% and 1.7136% respectively. The quality control of iodine test in urine using the control chart shows excellent or stable results for 30 days and no variation of the results is very different for each day.

  2. Measurement of bone marrow lesions by MR imaging in knee osteoarthritis using quantitative segmentation methods--a reliability and sensitivity to change analysis.

    PubMed

    Nielsen, Flemming K; Egund, Niels; Peters, David; Jurik, Anne Grethe

    2014-12-20

    Longitudinal assessment of bone marrow lesions (BMLs) in knee osteoarthritis (KOA) by MRI is usually performed using semi-quantitative grading methods. Quantitative segmentation methods may be more sensitive to detect change over time. The purpose of this study was to evaluate and compare the validity and sensitivity to detect changes of two quantitative MR segmentation methods for measuring BMLs in KOA, one computer assisted (CAS) and one manual (MS) method. Twenty-two patients with KOA confined to the medial femoro-tibial compartment obtained MRI at baseline and follow-up (median 334 days in between). STIR, T1 and fat saturated T1 post-contrast sequences were obtained using a 1.5 T system. The 44 sagittal STIR sequences were assessed independently by two readers for quantification of BML. The signal intensities (SIs) of the normal bone marrow in the lateral femoral condyles and tibial plateaus were used as threshold values. The volume of bone marrow with SIs exceeding the threshold values (BML) was measured in the medial femoral condyle and tibial plateau and related to the total volume of the condyles/plateaus.The 95% limits of agreement at baseline were used to determine the sensitivity to change. The mean threshold values of CAS and MS were almost identical but the absolute and relative BML volumes differed being 1319 mm3/10% and 1828 mm3/15% in the femur and 941 mm3/7% and 2097 mm3/18% in the tibia using CAS and MS, respectively. The BML volumes obtained by CAS and MS were significantly correlated but the tissue changes measured were different. The volume of voxels exceeding the threshold values was measured by CAS whereas MS included intervening voxels with normal SI.The 95% limits of agreement were narrower by CAS than by MS; a significant change of relative BML by CAS was outside the limits of -2.0%-4.7% whereas the limits by MS were -6.9%-8.2%. The BML changed significantly in 13 knees using CAS and in 10 knees by MS. CAS was a reliable method for measuring BML and more sensitive to detect changes over time than MS. The BML volumes measured by the two methods differed but were significantly correlated.

  3. An analysis of I/O efficient order-statistic-based techniques for noise power estimation in the HRMS sky survey's operational system

    NASA Technical Reports Server (NTRS)

    Zimmerman, G. A.; Olsen, E. T.

    1992-01-01

    Noise power estimation in the High-Resolution Microwave Survey (HRMS) sky survey element is considered as an example of a constant false alarm rate (CFAR) signal detection problem. Order-statistic-based noise power estimators for CFAR detection are considered in terms of required estimator accuracy and estimator dynamic range. By limiting the dynamic range of the value to be estimated, the performance of an order-statistic estimator can be achieved by simpler techniques requiring only a single pass of the data. Simple threshold-and-count techniques are examined, and it is shown how several parallel threshold-and-count estimation devices can be used to expand the dynamic range to meet HRMS system requirements with minimal hardware complexity. An input/output (I/O) efficient limited-precision order-statistic estimator with wide but limited dynamic range is also examined.

  4. Solid phase microextraction applied to the analysis of organophosphorus insecticides in fruits.

    PubMed

    Fytianos, K; Raikos, N; Theodoridis, G; Velinova, Z; Tsoukali, H

    2006-12-01

    Trace amounts of organophosphorus pesticides (OPs) were determined in various fruits by headspace solid phase microextraction (HS-SPME) and gas chromatography-nitrogen phosphorous detection (GC-NPD). Sampling from the headspace enhanced method selectivity, whereas at the same time improved fiber life time and method sensitivity. Diazinon, parathion, methyl parathion, malathion and fenithrothion were determined in various fruits: more than 150 samples of 21 types of fruits were studied. SPME-GC-NPD provided a useful and very efficient analytical tool: method linearity ranged from 1.2 to 700 ng/ml. Limits of detection (LODs) and quantitation (LOQs) ranged from 0.03 to 3 ng/ml and 0.12 to 10 ng/ml respectively, values well below the residue limits set by the EU. Less than 2% of the samples were found positive containing amounts higher than the EU limits. The effect of fruit peeling and washing was also investigated.

  5. [Radioactive cesium analysis in radiation-tainted beef by gamma-ray spectrometry with germanium semiconductor detector].

    PubMed

    Minatani, Tomiaki; Nagai, Hiroyuki; Nakamura, Masashi; Otsuka, Kimihito; Sakai, Yoshimichi

    2012-01-01

    The detection limit and precision of radioactive cesium measurement in beef by gamma-ray spectrometry with a germanium semiconductor detector were evaluated. Measurement for 2,000 seconds using a U-8 container (100 mL) provided a detection limit of radioactive cesium (the sum of 134Cs and 137Cs) of around 20 Bq/kg. The 99% confidence interval of the measurement of provisional maximum residue limit level (491 Bq/kg) samples ranged from 447 to 535 Bq/kg. Beef is heterogeneous, containing muscle and complex fat layers. Depending on the sampled parts, the measurement value is variable. It was found that radioactive cesium content of the muscle layer was clearly different from that of fat, and slight differences were observed among parts of the sample (SD=16.9 Bq/kg), even though the same region (neck block) of beef sample was analyzed.

  6. Rapid and sensitive detection of malachite green in aquaculture water by electrochemical preconcentration and surface-enhanced Raman scattering.

    PubMed

    Xu, Kai-Xuan; Guo, Mei-Hong; Huang, Yu-Ping; Li, Xiao-Dong; Sun, Jian-Jun

    2018-04-01

    A highly sensitive and rapid method of in-situ surface-enhanced Raman spectroscopy (SERS) combining with electrochemical preconcentration (EP) in detecting malachite green (MG) in aquaculture water was established. Ag nanoparticles (AgNPs) were synthesized and spread onto the surface of gold electrodes after centrifuging to produce SERS-active substrates. After optimizing the pH values, preconcentration potentials and times, in-situ EP-SERS detection was carried out. A sensitive and rapid analysis of the low-concentration MG was accomplished within 200s and the limit of detection was 2.4 × 10 -16 M. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Ultrasonic technique for detection of liquids in copper tubing process lines

    NASA Astrophysics Data System (ADS)

    Dudley, W. A.

    1980-10-01

    An ultrasonic pulse-echo method developed for semiquantitative measurement of liquid levels in copper tubing is described. This ultrasonic approach is of particular value when used as a pre-maintenance diagnostic tool in repairing process lines containing hazardous liquids. Performance tests show that water and similar liquids can be directly detected to fill levels as low as 1/16 in. For water fills below 1/16 in., direct level detection is impractical because of signal resolution limitations. However, this fill condition is indirectly measurable and is detected by the effect of observed degradation of the adjacent wall echo pattern. Fill conditions for liquids associated with high sound attenuation such as oil can be indirectly determined.

  8. Chemiluminescence detection of peroxynitrite with flow injection

    NASA Astrophysics Data System (ADS)

    Kang, Dai; Evmiridis, Nick P.; Vlessidis, Athanasios; Zhou, Yikai

    2001-09-01

    Peroxynitrite is an important derivative made by nitric oxide in vivo. It can make damages in many kinds of tissue and cells. Its research value in heart disease and cancer is a very high. A sensitive, specific method for analysis of peroxynitrite is described. In this method, chemiluminescence reaction between perodynitrite and luminol was used to detect with flow injection system. The assay has a detection limit of 2 by 10-8 mol L-1, and linear range of 5 by 10-8 mol L-1 to 5 by 10-5 mol L-1. The application o f flow injection system offers the possibility to establish biosensor for real-time detection of perodynitrite.

  9. GIS-based niche modeling for mapping species' habitats

    USGS Publications Warehouse

    Rotenberry, J.T.; Preston, K.L.; Knick, S.

    2006-01-01

    Ecological a??niche modelinga?? using presence-only locality data and large-scale environmental variables provides a powerful tool for identifying and mapping suitable habitat for species over large spatial extents. We describe a niche modeling approach that identifies a minimum (rather than an optimum) set of basic habitat requirements for a species, based on the assumption that constant environmental relationships in a species' distribution (i.e., variables that maintain a consistent value where the species occurs) are most likely to be associated with limiting factors. Environmental variables that take on a wide range of values where a species occurs are less informative because they do not limit a species' distribution, at least over the range of variation sampled. This approach is operationalized by partitioning Mahalanobis D2 (standardized difference between values of a set of environmental variables for any point and mean values for those same variables calculated from all points at which a species was detected) into independent components. The smallest of these components represents the linear combination of variables with minimum variance; increasingly larger components represent larger variances and are increasingly less limiting. We illustrate this approach using the California Gnatcatcher (Polioptila californica Brewster) and provide SAS code to implement it.

  10. Multispecies breath analysis faster than a single respiratory cycle by optical-feedback cavity-enhanced absorption spectroscopy

    NASA Astrophysics Data System (ADS)

    Ventrillard-Courtillot, Irene; Gonthiez, Thierry; Clerici, Christine; Romanini, Daniel

    2009-11-01

    We demonstrate a first application, of optical-feedback cavity-enhanced absorption spectroscopy (OF-CEAS) to breath analysis in a medical environment. Noninvasive monitoring of trace species in exhaled air was performed simultaneous to spirometric measurements on patients at Bichat Hospital (Paris). The high selectivity of the OF-CEAS spectrometer and a time response of 0.3 s (limited by sample flow rate) allowed following the evolution of carbon monoxide and methane concentrations during individual respiratory cycles, and resolving variations among different ventilatory patterns. The minimum detectable absorption on this time scale is about 3×10-10 cm-1. At the working wavelength of the instrument (2.326 μm), this translates to concentration detection limits of ~1 ppbv (45 picomolar, or ~1.25 μg/m3) for CO and 25 ppbv for CH4, well below concentration values found in exhaled air. This same instrument is also able to provide measurement of NH3 concentrations with a detection limit of ~10 ppbv however, at present, memory effects do not allow its measurement on fast time scales.

  11. Automated system for on-line determination of dimethylarsinic and inorganic arsenic by hydride generation-atomic fluorescence spectrometry.

    PubMed

    Chaparro, L L; Ferrer, L; Cerdà, V; Leal, L O

    2012-09-01

    A multisyringe flow-injection approach has been coupled to hydride generation-atomic fluorescence spectrometry (HG-AFS) with UV photo-oxidation for dimethylarsinic (DMA), inorganic As and total As determination, depending on the pre-treatment given to the sample (extraction or digestion). The implementation of a UV lamp allows on-line photo-oxidation of DMA and the following arsenic detection, whereas a bypass leads the flow directly to the HG-AFS system, performing inorganic arsenic determination. DMA concentration is calculated by the difference of total inorganic arsenic and measurement of the photo-oxidation step. The detection limits for DMA and inorganic arsenic were 0.09 and 0.47 μg L(-1), respectively. The repeatability values accomplished were of 2.4 and 1.8%, whereas the injection frequencies were 24 and 28 injections per hour for DMA and inorganic arsenic, respectively. This method was validated by means of a solid reference material BCR-627 (muscle of tuna) with good agreement with the certified values. Satisfactory results for DMA and inorganic arsenic determination were obtained in several water matrices. The proposed method offers several advantages, such as increasing the sampling frequency, low detection limits and decreasing reagents and sample consumption, which leads to lower waste generation.

  12. Analysis of explosives using corona discharge ionization combined with ion mobility spectrometry-mass spectrometry.

    PubMed

    Lee, Jihyeon; Park, Sehwan; Cho, Soo Gyeong; Goh, Eun Mee; Lee, Sungman; Koh, Sung-Suk; Kim, Jeongkwon

    2014-03-01

    Corona discharge ionization combined with ion mobility spectrometry-mass spectrometry (IMS-MS) was utilized to investigate five common explosives: cyclonite (RDX), trinitrotoluene (TNT), pentaerythritol tetranitrate (PETN), cyclotetramethylenetetranitramine (HMX), and 2,4-dinitrotoluene (DNT). The MS scan and the selected ion IMS analyses confirmed the identities of the existing ion species and their drift times. The ions observed were RDX·NO3(-), TNT(-), PETN·NO3(-), HMX·NO3(-), and DNT(-), with average drift times of 6.93 ms, 10.20 ms, 9.15 ms, 12.24 ms, 11.30 ms, and 8.89 ms, respectively. The reduced ion mobility values, determined from a standard curve calculated by linear regression of (normalized drift times)(-1) versus literature K0 values, were 2.09, 1.38, 1.55, 1.15, 1.25, and 1.60 cm(2) V(-1) s(-1), respectively. The detection limits were found to be 0.1 ng for RDX, 10 ng for TNT, 0.5 ng for PETN, 5.0 ng for HMX, and 10 ng for DNT. Simplified chromatograms were observed when nitrogen, as opposed to air, was used as the drift gas, but the detection limits were approximately 10 times worse (i.e., less sensitivity of detection). © 2013 Elsevier B.V. All rights reserved.

  13. A gold nanoparticle-based semi-quantitative and quantitative ultrasensitive paper sensor for the detection of twenty mycotoxins

    NASA Astrophysics Data System (ADS)

    Kong, Dezhao; Liu, Liqiang; Song, Shanshan; Suryoprabowo, Steven; Li, Aike; Kuang, Hua; Wang, Libing; Xu, Chuanlai

    2016-02-01

    A semi-quantitative and quantitative multi-immunochromatographic (ICA) strip detection assay was developed for the simultaneous detection of twenty types of mycotoxins from five classes, including zearalenones (ZEAs), deoxynivalenols (DONs), T-2 toxins (T-2s), aflatoxins (AFs), and fumonisins (FBs), in cereal food samples. Sensitive and specific monoclonal antibodies were selected for this assay. The semi-quantitative results were obtained within 20 min by the naked eye, with visual limits of detection for ZEAs, DONs, T-2s, AFs and FBs of 0.1-0.5, 2.5-250, 0.5-1, 0.25-1 and 2.5-10 μg kg-1, and cut-off values of 0.25-1, 5-500, 1-10, 0.5-2.5 and 5-25 μg kg-1, respectively. The quantitative results were obtained using a hand-held strip scan reader, with the calculated limits of detection for ZEAs, DONs, T-2s, AFs and FBs of 0.04-0.17, 0.06-49, 0.15-0.22, 0.056-0.49 and 0.53-1.05 μg kg-1, respectively. The analytical results of spiked samples were in accordance with the accurate content in the simultaneous detection analysis. This newly developed ICA strip assay is suitable for the on-site detection and rapid initial screening of mycotoxins in cereal samples, facilitating both semi-quantitative and quantitative determination.A semi-quantitative and quantitative multi-immunochromatographic (ICA) strip detection assay was developed for the simultaneous detection of twenty types of mycotoxins from five classes, including zearalenones (ZEAs), deoxynivalenols (DONs), T-2 toxins (T-2s), aflatoxins (AFs), and fumonisins (FBs), in cereal food samples. Sensitive and specific monoclonal antibodies were selected for this assay. The semi-quantitative results were obtained within 20 min by the naked eye, with visual limits of detection for ZEAs, DONs, T-2s, AFs and FBs of 0.1-0.5, 2.5-250, 0.5-1, 0.25-1 and 2.5-10 μg kg-1, and cut-off values of 0.25-1, 5-500, 1-10, 0.5-2.5 and 5-25 μg kg-1, respectively. The quantitative results were obtained using a hand-held strip scan reader, with the calculated limits of detection for ZEAs, DONs, T-2s, AFs and FBs of 0.04-0.17, 0.06-49, 0.15-0.22, 0.056-0.49 and 0.53-1.05 μg kg-1, respectively. The analytical results of spiked samples were in accordance with the accurate content in the simultaneous detection analysis. This newly developed ICA strip assay is suitable for the on-site detection and rapid initial screening of mycotoxins in cereal samples, facilitating both semi-quantitative and quantitative determination. Electronic supplementary information (ESI) available. See DOI: 10.1039/c5nr09171c

  14. Interferon-γ–Inducible Protein 10 (IP-10) as a Screening Tool to Optimize Human Immunodeficiency Virus RNA Monitoring in Resource-Limited Settings

    PubMed Central

    Pastor, Lucía; Casellas, Aina; Carrillo, Jorge; Maculuve, Sonia; Jairoce, Chenjerai; Paredes, Roger; Blanco, Julià; Naniche, Denise

    2017-01-01

    Abstract Background Achieving effective antiretroviral treatment (ART) monitoring is a key determinant to ensure viral suppression and reach the UNAIDS 90-90-90 targets. The gold standard for detecting virological failure is plasma human immunodeficiency virus (HIV) RNA (viral load [VL]) testing; however, its availability is very limited in low-income countries due to cost and operational constraints. Methods HIV-1–infected adults on first-line ART attending routine visits at the Manhiça District Hospital, Mozambique, were previously evaluated for virologic failure. Plasma levels of interferon-γ–inducible protein 10 (IP-10) were quantified by enzyme-linked immunosorbent assay. Logistic regression was used to build an IP-10–based model able to identify individuals with VL >150 copies/mL. From the 316 individuals analyzed, 253 (80%) were used for model training and 63 (20%) for validation. Receiver operating characteristic curves were employed to evaluate model prediction. Results From the individuals included in the training set, 34% had detectable VL. Mean age was 41 years, 70% were females, and median time on ART was 3.4 years. IP-10 levels were significantly higher in subjects with detectable VL (108.2 pg/mL) as compared to those with undetectable VL (38.0 pg/mL) (P < .0001, U test). IP-10 univariate model demonstrated high classification performance (area under the curve = 0.85 [95% confidence interval {CI}, .80–.90]). Using a cutoff value of IP-10 ≥44.2 pg/mL, the model identified detectable VL with 91.9% sensitivity (95% CI, 83.9%–96.7%) and 59.9% specificity (95% CI, 52.0%–67.4%), values confirmed in the validation set. Conclusions IP-10 is an accurate biomarker to screen individuals on ART for detectable viremia. Further studies should evaluate the benefits of IP-10 as a triage approach to monitor ART in resource-limited settings. PMID:29020145

  15. Comparing the outcomes of two strategies for colorectal tumor detection: policy-promoted screening program versus health promotion service.

    PubMed

    Wu, Ping-Hsiu; Lin, Yu-Min; Liao, Chao-Sheng; Chang, Hung-Chuen; Chen, Yu-Hung; Yang, Kuo-Ching; Shih, Chia-Hui

    2013-06-01

    The Taiwanese government has proposed a population-based colorectal tumor detection program for the average-risk population. This study's objectives were to understand the outcomes of these screening policies and to evaluate the effectiveness of the program. We compared two databases compiled in one medical center. The "policy-promoted cancer screening" (PPS) database was built on the basis of the policy of the Taiwan Bureau of National Health Insurance for cancer screening. The "health promotion service" (HPS) database was built to provide health check-ups for self-paid volunteers. Both the PPS and HPS databases employ the immunochemical fecal occult blood test (iFOBT) and colonoscopy for colorectal tumor screening using different strategies. A comparison of outcomes between the PPS and HPS included: (1) quality indicators-compliance rate, cecum reaching rate, and tumor detection rate; and (2) validity indicators-sensitivity, specificity, positive, and negative predictive values for detecting colorectal neoplasms. A total of 10,563 and 1481 individuals were enrolled in PPS and HPS, respectively. Among quality indicators, there was no statistically significant difference in the cecum reaching rate between PPS and HPS. The compliance rates were 56.1% for PPS and 91.8% for HPS (p < 0.001). The advanced adenoma detection rates of PPS and HPS were 1.0% and 3.6%, respectively (p < 0.01). The carcinoma detection rates were 0.3% and 0.4%, respectively (p = 0.59). For validity indicators, PPS provides only a positive predictive value for colorectal tumor detection. HPS provides additional validity indicators, including sensitivity, specificity, positive predictive value, and negative predictive value, for colorectal tumor screening. In comparison with the outcomes of the HPS database, the screening efficacy of the PPS database is even for detecting colorectal carcinoma but is limited in detecting advanced adenoma. HPS may provide comprehensive validity indicators and will be helpful in adjusting current policies for improving screening performance. Copyright © 2013. Published by Elsevier B.V.

  16. Upper limits for X-ray emission from Jupiter as measured from the Copernicus satellite

    NASA Technical Reports Server (NTRS)

    Vesecky, J. F.; Culhane, J. L.; Hawkins, F. J.

    1975-01-01

    X-ray telescopic observations are made by the Copernicus satellite for detecting X-ray emission from Jupiter analogous to X-rays from terrestrial aurorae. Values of X-ray fluxes recorded by three Copernicus detectors covering the 0.6 to 7.5 keV energy range are reported. The detectors employed are described and the times at which the observations were made are given. Resulting upper-limit spectra are compared with previous X-ray observations of Jupiter. The upper-limit X-ray fluxes are discussed in terms of magnetospheric activity on Jupiter.

  17. Stereometric parameters change vs. Topographic Change Analysis (TCA) agreement in Heidelberg Retina Tomography III (HRT-3) early detection of clinical significant glaucoma progression.

    PubMed

    Dascalu, A M; Cherecheanu, A P; Stana, D; Voinea, L; Ciuluvica, R; Savlovschi, C; Serban, D

    2014-01-01

    to investigate the sensitivity and specificity of the stereometric parameters change analysis vs. Topographic Change Analysis in early detection of glaucoma progression. 81 patients with POAG were monitored for 4 years (GAT monthly, SAP at every 6 months, optic disc photographs and HRT3 yearly). The exclusion criteria were other optic disc or retinal pathology; topographic standard deviation (TSD>30; inter-test variation of reference height>25 μm. The criterion for structural progression was the following: at least 20 adjacent super-pixels with a clinically significant decrease in height (>5%). 16 patients of the total 81 presented structural progression on TCA. The most useful stereometric parameters for the early detection of glaucoma progression were the following: Rim Area change (sensitivity 100%, specificity 74.2% for a "cut-off " value of -0.05), C/D Area change (sensitivity 85.7%, specificity 71.5% for a "cut off " value of 0.02), C/D linear change (sensitivity 85.7%, specificity 71.5% for a "cut-off " value of 0.02), Rim Volume change (sensitivity 71.4%, specificity 88.8% for a "cut-off " value of -0.04). RNFL Thickness change (<0) was highly sensitive (82%), but less specific for glaucoma progression (45,2%). Changes of the other stereometric parameters have a limited diagnostic value for the early detection of glaucoma progression. TCA is a valuable tool for the assessment of the structural progression in glaucoma patients and its inter-test variability is low. On long-term, the quantitative analysis according to stereometric parameters change is also very important. The most relevant parameters to detect progression are RA, C/D Area, Linear C/D and RV.

  18. Automatic learning of rules. A practical example of using artificial intelligence to improve computer-based detection of myocardial infarction and left ventricular hypertrophy in the 12-lead ECG.

    PubMed

    Kaiser, W; Faber, T S; Findeis, M

    1996-01-01

    The authors developed a computer program that detects myocardial infarction (MI) and left ventricular hypertrophy (LVH) in two steps: (1) by extracting parameter values from a 10-second, 12-lead electrocardiogram, and (2) by classifying the extracted parameter values with rule sets. Every disease has its dedicated set of rules. Hence, there are separate rule sets for anterior MI, inferior MI, and LVH. If at least one rule is satisfied, the disease is said to be detected. The computer program automatically develops these rule sets. A database (learning set) of healthy subjects and patients with MI, LVH, and mixed MI+LVH was used. After defining the rule type, initial limits, and expected quality of the rules (positive predictive value, minimum number of patients), the program creates a set of rules by varying the limits. The general rule type is defined as: disease = lim1l < p1 < or = lim1u and lim2l < p2 < or = lim2u and ... limnl < pn < or = limnu. When defining the rule types, only the parameters (p1 ... pn) that are known as clinical electrocardiographic criteria (amplitudes [mV] of Q, R, and T waves and ST-segment; duration [ms] of Q wave; frontal angle [degrees]) were used. This allowed for submitting the learned rule sets to an independent investigator for medical verification. It also allowed the creation of explanatory texts with the rules. These advantages are not offered by the neurons of a neural network. The learned rules were checked against a test set and the following results were obtained: MI: sensitivity 76.2%, positive predictive value 98.6%; LVH: sensitivity 72.3%, positive predictive value 90.9%. The specificity ratings for MI are better than 98%; for LVH, better than 90%.

  19. The serum anion gap in the evaluation of acid-base disorders: what are its limitations and can its effectiveness be improved?

    PubMed

    Kraut, Jeffrey A; Nagami, Glenn T

    2013-11-01

    The serum anion gap has been utilized to identify errors in the measurement of electrolytes, to detect paraproteins, and, most relevant to the nephrologist, to evaluate patients with suspected acid-base disorders. In regard to the latter purpose, traditionally an increased anion gap is identified when it exceeds the upper limit of normal for a particular clinical laboratory measurement. However, because there is a wide range of normal values (often 8-10 mEq/L), an increase in anion concentration can be present in the absence of an increased anion gap. In addition, the type of retained anion can affect the magnitude of the increase in anion gap relative to change in serum [HCO3(-)] being greater with lactic acidosis compared with ketoacidosis. This review examines the methods of calculation of the serum anion gap in textbooks and published literature, the effect of perturbations other than changes in acid-base balance, and its effectiveness in identifying mild and more severe disturbances in acid-base balance. Limitations of the present methods of determining the normal anion gap and change in the anion gap are highlighted. The possibility of identifying the baseline value for individuals to optimize the use of the calculation in the detection of metabolic acidosis is suggested.

  20. Strategy for determination of LOD and LOQ values--some basic aspects.

    PubMed

    Uhrovčík, Jozef

    2014-02-01

    The paper is devoted to the evaluation of limit of detection (LOD) and limit of quantification (LOQ) values in concentration domain by using 4 different approaches; namely 3σ and 10σ approaches, ULA2 approach, PBA approach and MDL approach. Brief theoretical analyses of all above mentioned approaches are given together with directions for their practical use. Calculations and correct calibration design are exemplified by using of electrothermal atomic absorption spectrometry for determination of lead in drinking water sample. These validation parameters reached 1.6 μg L(-1) (LOD) and 5.4 μg L(-1) (LOQ) by using 3σ and 10σ approaches. For obtaining relevant values of analyte concentration the influence of calibration design and measurement methodology were examined. The most preferred technique has proven to be a method of preconcentration of the analyte on the surface of the graphite cuvette (boost cycle). © 2013 Elsevier B.V. All rights reserved.

  1. Detection of corn adulteration in Brazilian coffee (Coffea arabica) by tocopherol profiling and near-infrared (NIR) spectroscopy

    USDA-ARS?s Scientific Manuscript database

    Coffee is a high-value commodity that is a target for adulteration, especially after the beans have been roasted and ground. Countries such as Brazil, the second largest coffee producer, have set limits on the allowable amount of coffee contamination and adulteration. Therefore, there is significant...

  2. An experiment to detect gut monopoles

    NASA Technical Reports Server (NTRS)

    Macneill, G.; Fegan, D. J.

    1985-01-01

    Recent advances in the development of Grand Unification Theories have led to several interesting predictions. One of these states that Grand Unification Monopoles (GUMs) exist as solutions in may nonabelian gauge theories. Another consequence of Unification is the possibility of baryon decay. The efficiency of the water tank detector in registering a Rubakov type decay will vary with both the interaction length and the GUM's velocity, expressed in terms of beta ( 0.01). The efficiency decreases at large values of because of the limited resolving time of the detector (approx. 50 ns). At lower values of Beta the time between interactions is such that the criterion of 4 events in 2 mu s can no longer be satisfied. The Rubakov experiment has now been in operation for almost 2 years with an estimated live time of 80%. During this time no candidate events have been observed leading to an estimated upper limit on the flux of 7.82 x 0.00001 m(-2) d(-1) Sr(-1). The ionization loss detection system has only recently come on line and as yet no results are available from this experiment.

  3. Simultaneous HPTLC Determination of Rabeprazole and Itopride Hydrochloride From Their Combined Dosage Form

    PubMed Central

    Suganthi, A.; John, Sofiya; Ravi, T. K.

    2008-01-01

    A simple, precise, sensitive, rapid and reproducible HPTLC method for the simultaneous estimation of the rabeprazole and itopride hydrochloride in tablets was developed and validated. This method involves separation of the components by TLC on precoated silica gel G60F254 plate with solvent system of n-butanol, toluene and ammonia (8.5:0.5:1 v/v/v) and detection was carried out densitometrically using a UV detector at 288 nm in absorbance mode. This system was found to give compact spots for rabeprazole (Rf value of 0.23 0.02) and for itopride hydrochloride (Rf value of 0.75±0.02). Linearity was found to be in the range of 40-200 ng/spot and 300-1500 ng/spot for rabeprazole and itopride hydrochloride. The limit of detection and limit of quantification for rabeprazole were 10 and 20 ng/spot and for itopride hydrochloride were 50 and 100 ng/spot, respectively. The method was found to be beneficial for the routine analysis of combined dosage form. PMID:20046748

  4. Biometric values, C-reactive protein, and proteinogram of healthy blonde capuchin (Sapajus flavius) kept in northeast of Brazil.

    PubMed

    Mota, Stéphanie Machado; Ferreira, Adriano Fernandes; Azevedo, Jair; Nery, Thiago Lopes; Zermiani, Fabiana; Queiroga, Felisbina Luisa

    2016-12-01

    Sapajus flavius is a species of capuchin monkey classified as critically endangered. Studies related to their biometric values are scarce with incomplete external measurement reports available from only four specimens. Moreover, information regarding proteinogram is limited with no reference to C-reactive protein (CRP) and globulin fractions for this species. Biometric values, CRP, and proteinogram were determined for 12 clinically healthy S. flavius, kept in captivity in João Pessoa, Brazil. The measured values in biometric parameters present a tendency to be higher in males. The CRP mean values from 12 S. flavius were 1.2±0.2 mg/dL. For albumin, alpha, beta, and gamma globulin fraction parameters, the reference interval was calculated. Authors believe that with certain limitations, results obtained can be helpful for the populations in the wild, which could be of great aid in detecting unhealthy individuals and therefore contributing to the conservation of this species. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  5. Clinical value of 18 FDG PET/CT in screening for distant metastases in head and neck squamous cell carcinoma.

    PubMed

    Deurvorst, S E; Hoekstra, O S; Castelijns, J A; Witte, B I; Leemans, C R; de Bree, R

    2018-06-01

    The detection of distant metastases is of major importance in management of head and neck squamous cell carcinoma patients. All patients underwent 18 FDG PET/CT for the detection of distant metastases. Retrospective single-centre study. Head and neck squamous cell carcinoma patients with high-risk factors for distant metastases. Accuracy of 18 FDG PET/CT for the detection of distant metastases using clinical development of distant metastases and a minimal follow-up of twelve months as reference standard. Comparison of overall survival between patients diagnosed with distant metastases during initial screening and patients diagnosed with distant metastases during follow-up. In 23 (12%) of the 190 patients, 18 FDG PET/CT detected distant metastases at screening. Sensitivity and negative predictive value were 46.2% (95% CI 32.6-59.7) and 82.6% (95% CI 76.8-88.5). No difference in median overall survival from the time of distant metastases detection was found between patients diagnosed with DM during work-up or during follow-up. In head and neck squamous cell carcinoma patients with high-risk factors, 18 FDG PET/CT has a high negative predictive value for the detection of distant metastases and should be used in daily clinical practice, although the sensitivity is limited when long-term follow-up is used as reference standard. © 2018 The Authors. Clinical Otolaryngology Published by John Wiley & Sons Ltd.

  6. Imaging of prostate cancer with PET/CT using 18F-Fluorocholine

    PubMed Central

    Vali, Reza; Loidl, Wolfgang; Pirich, Christian; Langesteger, Werner; Beheshti, Mohsen

    2015-01-01

    While 18F-Fluorodeoxyglucose (18F-FDG) Positron-Emission Tomography (PET) has limited value in prostate cancer (PCa), it may be useful for specific subgroups of PCa patients with hormone-resistant poorly differentiated cell types. 18F-Fluorocholine (18F-FCH) PET/CT has been increasingly used in primary and recurrent PCa and has been shown to add valuable information. Although there is a correlation between the foci of activity and the areas of malignancy in the prostate gland, the clinical value of 18F-FCH is still controversial for detection of the malignant focus in the prostate. For the T-staging of PCa at diagnosis the value of 18F-FCH is limited. This is probably due to limited resolution of PET system and positive findings in benign prostate diseases. Conversely, 18F-FCH PET/CT is a promising imaging modality for the delineation of local and distant nodal recurrence and bone metastases and is poised to have an impact on therapy management. In this review, recent studies of 18F-FCH PET/CT in PCa are summarized. PMID:25973332

  7. Estimation of risks by chemicals produced during laser pyrolysis of tissues

    NASA Astrophysics Data System (ADS)

    Weber, Lothar W.; Spleiss, Martin

    1995-01-01

    Use of laser systems in minimal invasive surgery results in formation of laser aerosol with volatile organic compounds of possible health risk. By use of currently identified chemical substances an overview on possibly associated risks to human health is given. The class of the different identified alkylnitriles seem to be a laser specific toxicological problem. Other groups of chemicals belong to the Maillard reaction type, the fatty acid pyrolysis type, or even the thermally activated chemolysis. In relation to the available different threshold limit values the possible exposure ranges of identified substances are discussed. A rough estimation results in an exposure range of less than 1/100 for almost all substances with given human threshold limit values without regard of possible interactions. For most identified alkylnitriles, alkenes, and heterocycles no threshold limit values are given for lack of, until now, practical purposes. Pyrolysis of anaesthetized organs with isoflurane gave no hints for additional pyrolysis products by fragment interactions with resulting VOCs. Measurements of pyrolysis gases resulted in detection of small amounts of NO additionally with NO2 formation at plasma status.

  8. GC and GC-MS determination of fluoroacetic acid and phenoxy acid herbicides via triphasal extractive pentafluorobenzylation using a polymer-bound phase-transfer catalyst.

    PubMed

    Miki, A; Tsuchihashi, H; Yamashita, M

    1998-01-01

    A simple and sensitive gas chromatography and gas chromatography-mass spectrometry (GC-MS) procedure has been developed for fluoroacetic acid (FA) and phenoxy acid herbicides (PAHs) via triphasal extractive pentafluorobenzylation. The triphasal system consisted of an aqueous sample, the extraction solvent toluene containing pentafluorobenzyl bromide as the derivatization reagent, and polymer-bound tri-n-butyl-methylphosphonium bromide as a phase-transfer catalyst, FA spiked in beverages, such as orange juice and milk, was extracted as its pentafluorobenzyl (PFB) derivative under moderate conditions (i.e., at a pH value of 6.5 at 60 degrees C). The detection limits were 0.10-0.20 microgram/mL by GC with electron-capture detection (GC-ECD), and 0.42-0.50 microgram/mL by full-scan GC-MS. PAHs were also detectable in the same manner within the detection limits of 0.05-0.10 microgram/mL by GC-ECD and 0.13-0.25 microgram/mL by full-scan GC-MS. Urine and serum which both contained 2,4-dichlorophenoxyacetic acid could also be analyzed by GC-MS after the triphasal pentafluorobenzylation. The detection limit was 0.20 microgram/mL in the full-scan mode and 10 ng/mL in the selected ion monitoring mode both for the urine and serum.

  9. Determination of Vitamin E in Cereal Products and Biscuits by GC-FID.

    PubMed

    Pasias, Ioannis N; Kiriakou, Ioannis K; Papakonstantinou, Lila; Proestos, Charalampos

    2018-01-01

    A rapid, precise and accurate method for the determination of vitamin E (α-tocopherol) in cereal products and biscuits has been developed. The uncertainty was calculated for the first time, and the methods were performed for different cereal products and biscuits, characterized as "superfoods". The limits of detection and quantification were calculated. The accuracy and precision were estimated using the certified reference material FAPAS T10112QC, and the determined values were in good accordance with the certified values. The health claims according to the daily reference values for vitamin E were calculated, and the results proved that the majority of the samples examined showed a percentage daily value higher than 15%.

  10. Determination of Vitamin E in Cereal Products and Biscuits by GC-FID

    PubMed Central

    Kiriakou, Ioannis K.; Papakonstantinou, Lila

    2018-01-01

    A rapid, precise and accurate method for the determination of vitamin E (α-tocopherol) in cereal products and biscuits has been developed. The uncertainty was calculated for the first time, and the methods were performed for different cereal products and biscuits, characterized as “superfoods”. The limits of detection and quantification were calculated. The accuracy and precision were estimated using the certified reference material FAPAS T10112QC, and the determined values were in good accordance with the certified values. The health claims according to the daily reference values for vitamin E were calculated, and the results proved that the majority of the samples examined showed a percentage daily value higher than 15%. PMID:29301245

  11. Detection of aflatoxin B₁ with immunochromatographic test strips: Enhanced signal sensitivity using gold nanoflowers.

    PubMed

    Ji, Yanwei; Ren, Meiling; Li, Yanping; Huang, Zhibing; Shu, Mei; Yang, Hongwei; Xiong, Yonghua; Xu, Yang

    2015-09-01

    Immunochromatographic test strips (ICTS) are commonly limited to higher concentrations of analytes. This limitation stems from the relatively low sensitivity of conventional gold nanospheres (AuNSs with a diameter of 20 nm) to emit detectable brightness values. The larger multi-branched gold nanoflowers (AuNFs) with a higher optical brightness as well as good colloidal stability exhibit significant improvements over conventional AuNSs for enhanced sensitivity of ICTS. In this study, blue AuNFs with an average diameter of 75±5 nm were synthetized and employed as a signal amplification probe for ultrasensitive and quantitative detection of aflatoxin B1 (AFB1) in rice. A portable optical strip reader was used to record the optical densities of test and control lines of the strip. Under the optimal conditions, the AuNF based ICTS system accurately detected AFB1 linearly and dynamically over the range of 0.5-25 pg/mL with a half maximal inhibitory concentration at 4.17 pg/mL. The inhibitory concentration was achieved 10 times lower than that of the traditional AuNS based ICTS systems (41.25 pg/mL). The limit of detection for AFB1 in rice extract was achieved at 0.32 pg/mL. In summary, AuNFs are a novel probe that exhibited excellent sensitivity in the ICTS system and could be used for ultrasensitive detection of other analytes in food safety monitoring, and even medical diagnostics. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Biological monitoring of 2,4,5-trichlorophenol (I): preparation of antibodies and development of an immunoassay using theoretical models.

    PubMed

    Nichkova, Mikaela; Galve, Roger; Marco, M-Pilar

    2002-11-01

    Antibodies against 2,4,5-trichlorophenol have been prepared after theoretical and molecular modeling chemical studies of three potential immunizing haptens with the aim to find out the one mimicking best the target analyte. Competitive direct and indirect ELISAs have been developed after screening a battery of haptenized enzyme tracers and coating antigens, respectively. The relation between the degree of heterology of the competitor and the resulting immunoassay detectability has been investigated according to the electronic similarities of the competitor haptens with the target analyte taking in consideration their pK(a) values. These studies have been performed using theoretical and molecular modeling tools to find out their electronic distribution at their minimum energetic levels. The results suggest that the competitors should have a high homology to produced assays with good detectability values. On the other hand detectability improves when lowering the hapten density of the competitors. An indirect competitive ELISA has been finally selected for further investigation. The immunoassay has an IC(50) value of 0.6 microg L(-)(1) and a limit of detection of 0.084 microg L(-)(1). The selectivity of the assay is high in relation to other chlorophenols frequently present in real samples. In contrast, the brominated analogues may also be recognized with this assay.

  13. Influence of oxygen availability on the metabolism and morphology of Yarrowia lipolytica: insights into the impact of glucose levels on dimorphism.

    PubMed

    Timoumi, Asma; Bideaux, Carine; Guillouet, Stéphane E; Allouche, Yohan; Molina-Jouve, Carole; Fillaudeau, Luc; Gorret, Nathalie

    2017-10-01

    Dynamic behavior of Yarrowia lipolytica W29 strain under conditions of fluctuating, low, and limited oxygen supply was characterized in batch and glucose-limited chemostat cultures. In batch cultures, transient oscillations between oxygen-rich and -deprived environments induced a slight citric acid accumulation (lower than 29 mg L -1 ). By contrast, no citric acid was detected in continuous fermentations for all stress conditions: full anoxia (zero pO 2 value, 100% N 2 ), limited (zero pO 2 value, 75% of cell needs), and low (pO 2 close to 2%) dissolved oxygen (DO) levels. The macroscopic behavior (kinetic parameters, yields, viability) of Y. lipolytica was not significantly affected by the exposure to DO fluctuations under both modes of culture. Nevertheless, conditions of oxygen limitation resulted in the destabilization of the glucose-limited growth during the continuous cultivations. Morphological responses of Y. lipolytica to DO oscillations were different between batch and chemostat runs. Indeed, a yeast-to-mycelium transition was induced and progressively intensified during the batch fermentations (filamentous subpopulation reaching 74% (v/v)). While, in chemostat bioreactors, the culture consisted mainly of yeast-like cells (mean diameter not exceeding 5.7 μm) with a normal size distribution. During the continuous cultures, growth at low DO concentration did not induce any changes in Y. lipolytica morphology. Dimorphism (up to 80.5% (v/v) of filaments) was only detected under conditions of oxygen limitation in the presence of a residual glucose excess (more than 0.75 g L -1 ). These data suggest an impact of glucose levels on the signaling pathways regulating dimorphic responses in Y. lipolytica.

  14. Osteoblastic lesion screening with an advanced post-processing package enabling in-plane rib reading in CT-images.

    PubMed

    Seuss, Hannes; Dankerl, Peter; Cavallaro, Alexander; Uder, Michael; Hammon, Matthias

    2016-05-20

    To evaluate screening and diagnostic accuracy for the detection of osteoblastic rib lesions using an advanced post-processing package enabling in-plane rib reading in CT-images. We retrospectively assessed the CT-data of 60 consecutive prostate cancer patients by applying dedicated software enabling in-plane rib reading. Reading the conventional multiplanar reconstructions was considered to be the reference standard. To simulate clinical practice, the reader was given 10 s to screen for sclerotic rib lesions in each patient applying both approaches. Afterwards, every rib was evaluated individually with both approaches without a time limit. Sensitivities, specificities, positive/negative predictive values and the time needed for detection were calculated depending on the lesion's size (largest diameter < 5 mm, 5-10 mm, > 10 mm). In 53 of 60 patients, all ribs were properly displayed in plane, in five patients ribs were partially displayed correctly, and in two patients none of the ribs were displayed correctly. During the 10-s screening approach all patients with sclerotic rib lesions were correctly identified reading the in-plane images (including the patients without a correct rib segmentation), whereas 14 of 23 patients were correctly identified reading conventional multiplanar images. Overall screening sensitivity, specificity, and positive/negative predictive values were 100/27.0/46.0/100 %, respectively, for in-plane reading and 60.9/100/100/80.4 %, respectively, for multiplanar reading. Overall diagnostic (no time limit) sensitivity, specificity, and positive/negative predictive values of in-plane reading were 97.8/92.8/74.6/99.5 %, respectively. False positive results predominantly occurred for lesions <5 mm in size. In-plane reading of the ribs allows reliable detection of osteoblastic lesions for screening purposes. The limited specificity results from false positives predominantly occurring for small lesions.

  15. Monitoring virologic responses to antiretroviral therapy in HIV-infected adults in Kenya: evaluation of a low-cost viral load assay.

    PubMed

    Sivapalasingam, Sumathi; Wangechi, Beatrice; Marshed, Fatuma; Laverty, Maura; Essajee, Shaffiq; Holzman, Robert S; Valentine, Fred

    2009-08-28

    A key advantage of monitoring HIV viral load (VL) in persons receiving antiretroviral therapy (ART) is the ability to detect virologic failure before clinical deterioration or resistance occurs. Detection of virologic failure will help clarify the need for enhanced adherence counseling or a change to second- line therapy. Low-cost, locally performable alternates to expensive VL assays are needed where resources are limited. We monitored the response to 48-week ART in 100 treatment-naïve Kenyan adults using a low-cost VL measurement, the Cavidi reverse transcriptase (RT) assay and gold-standard assays, Roche RNA PCR and Bayer Versant HIV-1 RNA (bDNA) assays. In Altman-Bland plots, the mean difference in viral loads between the three assays was small (<0.5 log(10) copies/mL). However, the limits of agreement between the methods exceeded the biologically relevant change of 0.5 log copies/ml. Therefore, the RT assay cannot be used interchangeably with the other assays to monitor individual patients. The RT assay was 100% sensitive in detecting viral loads of > or =400 copies/ml compared to gold-standard assays. After 24 weeks of treatment, viral load measured by the RT assay was undetectable in 95% of 65 patients with undetectable RNA PCR VL (<400 copies/ml), 90% of 67 patients with undetectable bDNA VL, and 96% of 57 patients with undetectable VL in both RNA PCR and bDNA assays. The negative predictive value of the RT assay was 100% compared to either assay; the positive predictive value was 86% compared to RNA PCR and 70% compared to bDNA. The RT assay compared well with gold standard assays. Our study highlights the importance of not interchanging viral load assays when monitoring an individual patient. Furthermore, the RT assay may be limited by low positive predictive values when used in populations with low prevalence of virologic failure.

  16. Monitoring Virologic Responses to Antiretroviral Therapy in HIV-Infected Adults in Kenya: Evaluation of a Low-Cost Viral Load Assay

    PubMed Central

    Sivapalasingam, Sumathi; Wangechi, Beatrice; Marshed, Fatuma; Laverty, Maura; Essajee, Shaffiq; Holzman, Robert S.; Valentine, Fred

    2009-01-01

    Background A key advantage of monitoring HIV viral load (VL) in persons receiving antiretroviral therapy (ART) is the ability to detect virologic failure before clinical deterioration or resistance occurs. Detection of virologic failure will help clarify the need for enhanced adherence counseling or a change to second- line therapy. Low-cost, locally performable alternates to expensive VL assays are needed where resources are limited. Methodology/Principal Findings We monitored the response to 48-week ART in 100 treatment-naïve Kenyan adults using a low-cost VL measurement, the Cavidi reverse transcriptase (RT) assay and gold-standard assays, Roche RNA PCR and Bayer Versant HIV-1 RNA (bDNA) assays. In Altman-Bland plots, the mean difference in viral loads between the three assays was small (<0.5 log10 copies/mL). However, the limits of agreement between the methods exceeded the biologically relevant change of 0.5 log copies/ml. Therefore, the RT assay cannot be used interchangeably with the other assays to monitor individual patients. The RT assay was 100% sensitive in detecting viral loads of ≥400 copies/ml compared to gold-standard assays. After 24 weeks of treatment, viral load measured by the RT assay was undetectable in 95% of 65 patients with undetectable RNA PCR VL (<400 copies/ml), 90% of 67 patients with undetectable bDNA VL, and 96% of 57 patients with undetectable VL in both RNA PCR and bDNA assays. The negative predictive value of the RT assay was 100% compared to either assay; the positive predictive value was 86% compared to RNA PCR and 70% compared to bDNA. Conclusion The RT assay compared well with gold standard assays. Our study highlights the importance of not interchanging viral load assays when monitoring an individual patient. Furthermore, the RT assay may be limited by low positive predictive values when used in populations with low prevalence of virologic failure. PMID:19714253

  17. The application of STEP-technology® for particle and protein dispersion detection studies in biopharmaceutical research.

    PubMed

    Gross-Rother, J; Herrmann, N; Blech, M; Pinnapireddy, S R; Garidel, P; Bakowsky, U

    2018-05-30

    Particle detection and analysis techniques are essential in biopharmaceutical industries to evaluate the quality of various parenteral formulations regarding product safety, product quality and to meet the regulations set by the authority agencies. Several particle analysis systems are available on the market, but for the operator, it is quite challenging to identify the suitable method to analyze the sample. At the same time these techniques are the basis to gain a better understanding in biophysical processes, e.g. protein interaction and aggregation processes. The STEP-Technology® (Space and Time resolved Extinction Profiles), as used in the analytical photocentrifuge LUMiSizer®, has been shown to be an effective and promising technique to investigate particle suspensions and emulsions in various fields. In this study, we evaluated the potentials and limitations of this technique for biopharmaceutical model samples. For a first experimental approach, we measured silica and polystyrene (PS) particle standard suspensions with given particle density and refractive index (RI). The concluding evaluation was performed using a variety of relevant data sets to demonstrate the significant influences of the particle density for the final particle size distribution (PSD). The most challenging property required for successful detection, turbidity, was stated and limits have been set based on the depicted absorbance value at 320 nm (A320 values). Furthermore, we produced chemically cross-linked protein particle suspensions to model physically "stable" protein aggregates. These results of LUMiSizer® analysis have been compared to the orthogonal methods of nanoparticle tracking analysis (NTA), dynamic light scattering (DLS) and micro-flow imaging (MFI). Sedimentation velocity distributions showed similar tendencies, but the PSDs and absolute size values could not be obtained. In conclusion, we could demonstrate some applications as well as limitations of this technique for biopharmaceutical samples. In comparison to orthogonal methods this technique is a great complementary approach if particle data e.g. density or refractive index can be determined. Copyright © 2018 Elsevier B.V. All rights reserved.

  18. [Detection of recombinant-DNA in foods from stacked genetically modified plants].

    PubMed

    Sorokina, E Iu; Chernyshova, O N

    2012-01-01

    A quantitative real-time multiplex polymerase chain reaction method was applied to the detection and quantification of MON863 and MON810 in stacked genetically modified maize MON 810xMON 863. The limit of detection was approximately 0,1%. The accuracy of the quantification, measured as bias from the accepted value and the relative repeatability standard deviation, which measures the intra-laboratory variability, were within 25% at each GM-level. A method verification has demonstrated that the MON 863 and the MON810 methods can be equally applied in quantification of the respective events in stacked MON810xMON 863.

  19. [Features of arterial blood pressure in elderly persons of different ethnic groups in Yakutsk].

    PubMed

    Nikitin, Iu P; Tatarinova, O V; Neustroeva, V N; Shcherbakova, L V; Sidorov, A S

    2013-01-01

    The differences in arterial blood pressure in the sample of population in the age of 60 and older of different ethnic groups in Yakutsk, as well as its connection with the other cardiovascular diseases risk factors have been analyzed. It was shown that the average values of systolic and diastolic blood pressure in subsample of the Yakuts appeared to be lower than in Caucasoid gerontic persons. The average values of systolic arterial blood pressure both in the Yakuts and in the Caucasoids were detected higher than normal values in all age-dependent subgroups. The average values of diastolic blood pressure in both ethnic groups were within the limits of high normal level. From 60 to 90 years and older the decrease in systolic and diastolic arterial blood pressure was detected; it was more marked in Caucasoid gerontic persons. The average values of pulse pressure in the Yakuts and in the Caucasoids appeared to be higher than the existing standard and didn't have any differences in ethnic groups. In both ethnical subsamples, pulse pressure values increase was observed in persons of 60-89 years old and its decrease after 90. Persons with overweight, obesity, central (abdominal) obesity, dyslypoproteidemias irrespective of belonging to ethnical group were characterized as having higher levels of arterial blood pressure. Statistically significant differences in the levels of arterial blood pressure in the Yakuts and in the Caucasoids depending on hyperglycemia, smoking, the presence of burdened anamnesis, educational level, marital status was not detected.

  20. Direct Quantification of Post-Stress-Rest Left Ventricular Motion and Thickening Changes for Myocardial Perfusion SPECT

    PubMed Central

    Karimi-Ashtiani, Shahryar; Arsanjani, Reza; Fish, Mathews; Kavanagh, Paul; Germano, Guido; Berman, Daniel; Slomka, Piotr

    2012-01-01

    Changes in myocardial wall motion and thickening during myocardial perfusion single-photon emission computed tomography (MPS) are typically assessed separately from gated studies to assess for stress induced functional abnormalities. We sought to develop and validate a novel approach for automatic quantification of post-stress-rest myocardial motion and thickening changes (MTC). Methods Endocardial surfaces at the end-diastolic and end-systolic frames for post-stress and rest studies were registered automatically to each other by matching ventricular surfaces. Myocardial MTCs were computed and normal limits of change were determined as the mean and standard deviation for each polar sample. Normal limits were utilized to quantify the MTCs for each map and the accumulated sample values were used for abnormality assessments in segmental regions. A hybrid method was devised by combining the Total Perfusion Deficit (TPD) and MTC for each vessel territory. Normal limits were obtained from 100 subjects with low likelihood (LLK) of coronary artery disease (CAD). For validation, 623 subjects with correlating invasive angiography were studied. All subjects had a stress/rest 99mTc-sestamibi exercise or adenosine test, and all had coronary angiography within 3 months of MPS. All MTC and TPD measurements were derived automatically. The diagnostic accuracy for detection of coronary artery disease for MTC+TPD was compared to TPD alone. Results Segmental normal values for motion change were between −1.3 and −4.1 mm and between −30.1% and −9.8% for thickening change. MTC combined with TPD achieved 61% sensitivity for 3-vessel disease (3VD), 63% for 2-vessel disease (2VD), and 90% for 1-vessel disease (1VD) detection vs. 32% for 3VD (P <0.0001), 53% for 2VD (P < 0.001), and 90% for 1VD (P = 1.0) detection with TPD alone method. The specificity for the combined method was 71% for 3VD, 72% for 2VD, and 47% for 1 VD detection vs. 90% for 3VD (P < 0.0001), 80% for 2VD (P <0.001), and 50% for 1VD detection (P=0.0625) for TPD alone method. The accuracy of 3VD detection by MTC+TPD was higher (69%) than the accuracy of TPD + change in ejection fraction (63%), (P< 0.004). Conclusion We established normal limits and a novel method for computation of regional functional changes between post-stress and rest. Combination of (TPD) with MTC improved the sensitivity for the detection of 3VD and 2VD as compared to TPD alone. PMID:22872739

  1. Improved detection of hereditary haemochromatosis.

    PubMed

    Ogilvie, Catherine; Gaffney, Dairena; Murray, Heather; Kerry, Andrew; Haig, Caroline; Spooner, Richard; Fitzsimons, Edward J

    2015-03-01

    There is high prevalence of hereditary haemochromatosis (HH) in North European populations, yet the diagnosis is often delayed or missed in primary care. Primary care physicians frequently request serum ferritin (SF) estimation but appear uncertain as how to investigate patients with raised SF values. Our aim was to develop a laboratory algorithm with high predictive value for the diagnosis of HH in patients from primary care with raised SF values. Transferrin saturation (Tsat) was measured on SF samples sent from primary care; 1657 male and 2077 female patients age ≥ 30 years with SF ≥ 200 μg/L. HFE genotyping was performed on all 878 male and 867 female patients with Tsat >30%. This study identified 402 (206 men; 196 women) C282Y carriers and 132 (58 men; 74 women) C282Y homozygotes. Optimal limits for combined SF and Tsat values for HH recognition were established. The detection rate for homozygous C282Y HH for male patients with both SF ≥ 300 μg/L and Tsat >50% was 18.8% (52/272) and 16.3% (68/415) for female patients with both SF ≥ 200 μg/L and Tsat >40%. The large number of SF requests received from primary care should be used as a resource to improve the diagnosis of HH in areas of high prevalence. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  2. Possibilities And Influencing Parameters For The Early Detection Of Sheet Metal Failure In Press Shop Operations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gerlach, Joerg; Kessler, Lutz; Paul, Udo

    2007-05-17

    The concept of forming limit curves (FLC) is widely used in industrial practice. The required data should be delivered for typical material properties (measured on coils with properties in a range of +/- of the standard deviation from the mean production values) by the material suppliers. In particular it should be noted that its use for the validation of forming robustness providing forming limit curves for the variety of scattering in the mechanical properties is impossible. Therefore a forecast of the expected limit strains without expensive cost and time-consuming experiments is necessary. In the paper the quality of a regressionmore » analysis for determining forming limit curves based on tensile test results is presented and discussed.Owing to the specific definition of limit strains with FLCs following linear strain paths, the significance of this failure definition is limited. To consider nonlinear strain path effects, different methods are given in literature. One simple method is the concept of limit stresses. It should be noted that the determined value of the critical stress is dependent on the extrapolation of the tensile test curve. When the yield curve extrapolation is very similar to an exponential function, the definition of the critical stress value is very complicated due to the low slope of the hardening function at large strains.A new method to determine general failure behavior in sheet metal forming is the common use and interpretation of three criteria: onset on material instability (comparable with FLC concept), value of critical shear fracture and the value of ductile fracture. This method seems to be particularly successful for newly developed high strength steel grades in connection with more complex strain paths for some specific material elements. Nevertheless the identification of the different failure material parameters or functions will increase and the user has to learn with the interpretation of the numerical results.« less

  3. Determination of As, Cd, Hg and Pb in continuous use drugs and excipients by plasma-based techniques in compliance with the United States Pharmacopeia requirements

    NASA Astrophysics Data System (ADS)

    da Silva, Caroline Santos; Pinheiro, Fernanda Costa; do Amaral, Clarice Dias Britto; Nóbrega, Joaquim Araújo

    2017-12-01

    Some inorganic impurities are toxic to human health even when present at low concentrations and therefore must be carefully monitored in products as continuous use drugs. This work aimed the development of a simple microwave-assisted digestion procedure for different types of drugs and excipients and the analytical determination of elemental impurities according to the new regulations of the United States Pharmacopeia (USP) 232 and 233 using inductively coupled plasma optical emission spectrometry (ICP-OES) or inductively coupled plasma mass spectrometry (ICP-MS). Eight drugs samples and two excipients of different brands were microwave-assisted digested with inverse aqua regia. Addition and recovery experiments were performed according to J values, once permissible daily exposure value is specific for each element and estimated according to the maximum daily dose of drug indicated by the label. Samples were spiked with values of 1.5J in order to check accuracies for As, Cd, Hg, and Pb. Recoveries obtained by ICP-OES ranged from 75 to 148% and for ICP-MS ranged from 74 to 120%. The limits of detection for ICP-OES ranged from 0.4 to 17 mg kg- 1 and for ICP-MS from 7.4 to 41.6 μg kg- 1. Both analytical methods were adequate in terms of accuracies and sensitivities. Considering the maximum daily dose, all drugs samples and excipients contained As, Cd, Hg and Pb below the maximum limits stipulated by USP since all of them presented contents below respective limits of detection.

  4. Innovative electrochemical approach for an early detection of microRNAs.

    PubMed

    Lusi, E A; Passamano, M; Guarascio, P; Scarpa, A; Schiavo, L

    2009-04-01

    The recent findings of circulating cell-free tissue specific microRNAs in the systemic circulation and the potential of their use as specific markers of disease highlight the need to make microRNAs testing a routine part of medical care. At the present time, microRNAs are detected by long and laborious techniques such as Northern blot, RT-PCR, and microarrays. The originality of our work consists in performing microRNAs detection through an electrochemical genosensor using a label-free method. We were able to directly detect microRNAs without the need of PCR and a labeling reaction. The test is simple, very fast and ultrasensitive, with a detection limit of 0.1 pmol. Particularly feasible for a routine microRNAs detection in serum and other biological samples, our technical approach would be of great scientific value and become a common method for simple miRNAs routine detection in both clinical and research settings.

  5. Occurrence and distribution of pesticides in surface waters of the Hood River basin, Oregon, 1999-2009

    USGS Publications Warehouse

    Temple, Whitney B.; Johnson, Henry M.

    2011-01-01

    The U.S. Geological Survey analyzed pesticide and trace-element concentration data from the Hood River basin collected by the Oregon Department of Environmental Quality (ODEQ) from 1999 through 2009 to determine the distribution and concentrations of pesticides in the basin's surface waters. Instream concentrations were compared to (1) national and State water-quality standards established to protect aquatic organisms and (2) concentrations that cause sublethal or lethal effects in order to assess their potential to adversely affect the health of salmonids and their prey organisms. Three salmonid species native to the basin are listed as "threatened" under the U.S. Endangered Species Act: bull trout, steelhead, and Chinook salmon. A subset of 16 sites was sampled every year by the ODEQ for pesticides, with sample collection targeted to months of peak pesticide use in orchards (March-June and September). Ten pesticides and four pesticide degradation products were analyzed from 1999 through 2008; 100 were analyzed in 2009. Nineteen pesticides were detected: 11 insecticides, 6 herbicides, and 2 fungicides. Two of four insecticide degradation products were detected. All five detected organophosphate insecticides and the one detected organochlorine insecticide were present at concentrations exceeding water-quality standards, sublethal effects thresholds, or acute toxicity values in one or more samples. The frequency of organophosphate detection in the basin decreased during the period of record; however, changes in sampling schedule and laboratory reporting limits hindered clear analysis of detection frequency trends. Detected herbicide and fungicide concentrations were less than water-quality standards, sublethal effects thresholds, or acute toxicity values. Simazine, the most frequently detected pesticide, was the only herbicide detected at concentrations within an order of magnitude (factor of 10) of concentrations that impact salmonid olfaction. Some detected pesticides are of concern, not for their toxicity alone, but for their ability to potentiate the harmful impacts of other pesticides, particularly organophosphates, on salmonids or their prey. Many samples contained mixtures of pesticides, but the effects to salmonids of relevant mixtures at environmentally realistic concentrations for the basin are unknown. Trace-element concentration data, although limited, indicate that eight trace elements are also of concern for their potential to harm salmonid health. The dataset is limited with regard to the spatial and seasonal distribution of pesticides and trace elements in all salmonid-bearing streams, the presence of particle-bound pesticides, and the presence of several unmonitored pesticides known to be used in the basin.

  6. The accuracy of confrontation visual field test in comparison with automated perimetry.

    PubMed Central

    Johnson, L. N.; Baloh, F. G.

    1991-01-01

    The accuracy of confrontation visual field testing was determined for 512 visual fields using automated static perimetry as the reference standard. The sensitivity of confrontation testing excluding patchy defects was 40% for detecting anterior visual field defects, 68.3% for posterior defects, and 50% for both anterior and posterior visual field defects combined. The sensitivity within each group varied depending on the type of visual field defect encountered. Confrontation testing had a high sensitivity (75% to 100%) for detecting altitudinal visual loss, central/centrocecal scotoma, and homonymous hemianopsia. Confrontation testing was fairly insensitive (20% to 50% sensitivity) for detecting arcuate scotoma and bitemporal hemianopsia. The specificity of confrontation testing was high at 93.4%. The high positive predictive value (72.6%) and negative predictive value (75.7%) would indicate that visual field defects identified during confrontation testing are often true visual field defects. However, the many limitations of confrontation testing should be remembered, particularly its low sensitivity for detecting visual field loss associated with parasellar tumors, glaucoma, and compressive optic neuropathies. PMID:1800764

  7. Medical chart validation of an algorithm for identifying multiple sclerosis relapse in healthcare claims.

    PubMed

    Chastek, Benjamin J; Oleen-Burkey, Merrikay; Lopez-Bresnahan, Maria V

    2010-01-01

    Relapse is a common measure of disease activity in relapsing-remitting multiple sclerosis (MS). The objective of this study was to test the content validity of an operational algorithm for detecting relapse in claims data. A claims-based relapse detection algorithm was tested by comparing its detection rate over a 1-year period with relapses identified based on medical chart review. According to the algorithm, MS patients in a US healthcare claims database who had either (1) a primary claim for MS during hospitalization or (2) a corticosteroid claim following a MS-related outpatient visit were designated as having a relapse. Patient charts were examined for explicit indication of relapse or care suggestive of relapse. Positive and negative predictive values were calculated. Medical charts were reviewed for 300 MS patients, half of whom had a relapse according to the algorithm. The claims-based criteria correctly classified 67.3% of patients with relapses (positive predictive value) and 70.0% of patients without relapses (negative predictive value; kappa 0.373: p < 0.001). Alternative algorithms did not improve on the predictive value of the operational algorithm. Limitations of the algorithm include lack of differentiation between relapsing-remitting MS and other types, and that it does not incorporate measures of function and disability. The claims-based algorithm appeared to successfully detect moderate-to-severe MS relapse. This validated definition can be applied to future claims-based MS studies.

  8. Detection of the Spermicide Nonoxynol-9 Via GC-MS

    NASA Astrophysics Data System (ADS)

    Musah, Rabi A.; Vuong, Angela L.; Henck, Colin; Shepard, Jason R. E.

    2012-05-01

    The spermicide nonoxynol-9 is actually a complex mixture of dozens of closely related amphiphilic compounds, and the chemical properties of this assortment significantly hamper its characterization by GC-MS. The inability to perform routine GC-MS testing on nonoxynol-9 has limited its evidentiary value in forensic casework, which relies heavily on this technique for analysis. A disturbing trend in sexual assault is the use of condoms by assailants, to avoid leaving behind DNA evidence that can connect a perpetrator to a victim. This observation necessitates the development of alternative methods for the analysis of trace evidence that can show causal links between a victim and a suspect. Detection of lubricants associated with sexual assault is one such way to establish this connection. The development of GC-MS methods that permit facile detection of both nonoxynol-9 alone and nonoxynol-9 extracted from other complex matrices that have potential as trace evidence in sexual assault is reported. A detection limit of 2.14 μg of nonoxynol-9 is demonstrated, and a detailed mass spectral profile that elaborates on what is known of its structure is provided.

  9. A chromogenic and fluorogenic rhodol-based chemosensor for hydrazine detection and its application in live cell bioimaging.

    PubMed

    Tiensomjitr, Khomsan; Noorat, Rattha; Chomngam, Sinchai; Wechakorn, Kanokorn; Prabpai, Samran; Kanjanasirirat, Phongthon; Pewkliang, Yongyut; Borwornpinyo, Suparerk; Kongsaeree, Palangpon

    2018-04-15

    A rhodol-based fluorescent probe has been developed as a selective hydrazine chemosensor using levulinate as a recognition site. The rhodol levulinate probe (RL) demonstrated high selectivity and sensitivity toward hydrazine among other molecules. The chromogenic response of RL solution to hydrazine from colorless to pink could be readily observed by the naked eye, while strong fluorescence emission could be monitored upon excitation at 525 nm. The detection process occurred via a ring-opening process of the spirolactone initiated by hydrazinolysis, triggering the fluorescence emission with a 53-fold enhancement. The probe rapidly reacted with hydrazine in aqueous medium with the detection limit of 26 nM (0.83 ppb), lower than the threshold limit value (TLV) of 10 ppb suggested by the U.S. Environmental Protection Agency. Furthermore, RL-impregnated paper strips could detect hydrazine vapor. For biological applicability of RL, its membrane-permeable property led to bioimaging of hydrazine in live HepG2 cells by confocal fluorescence microscopy. Copyright © 2018 Elsevier B.V. All rights reserved.

  10. Effects of Sampling and Spatio/Temporal Granularity in Traffic Monitoring on Anomaly Detectability

    NASA Astrophysics Data System (ADS)

    Ishibashi, Keisuke; Kawahara, Ryoichi; Mori, Tatsuya; Kondoh, Tsuyoshi; Asano, Shoichiro

    We quantitatively evaluate how sampling and spatio/temporal granularity in traffic monitoring affect the detectability of anomalous traffic. Those parameters also affect the monitoring burden, so network operators face a trade-off between the monitoring burden and detectability and need to know which are the optimal paramter values. We derive equations to calculate the false positive ratio and false negative ratio for given values of the sampling rate, granularity, statistics of normal traffic, and volume of anomalies to be detected. Specifically, assuming that the normal traffic has a Gaussian distribution, which is parameterized by its mean and standard deviation, we analyze how sampling and monitoring granularity change these distribution parameters. This analysis is based on observation of the backbone traffic, which exhibits spatially uncorrelated and temporally long-range dependence. Then we derive the equations for detectability. With those equations, we can answer the practical questions that arise in actual network operations: what sampling rate to set to find the given volume of anomaly, or, if the sampling is too high for actual operation, what granularity is optimal to find the anomaly for a given lower limit of sampling rate.

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gundlach-Graham, Alexander W.; Dennis, Elise; Ray, Steven J.

    Here we describe the first combination of a Distance-of-Flight Mass Spectrometry (DOFMS) instrument and an inductively coupled plasma (ICP) ion source. DOFMS is a velocity-based MS technique in which ions of a range of mass-to-charge (m/z) values are detected simultaneously along the length of a spatially selective detector. As a relative of time-of-flight (TOF) MS, DOFMS leverages benefits fromboth TOFMS and spatially dispersive MS. The simultaneous detection of groups of m/z values improves dynamic range by spreading ion signal across many detector elements and reduces correlated noise by signal ratioing. To ascertain the performance characteristics of the ICP-DOFMS instrument, wemore » have employed a microchannel-plate/phosphor detection assembly with a scientific CCD to capture images of the phosphor plate. With this simple (and commercially available) detection scheme, elemental detection limits from 2–30 ng L*1 and a linear dynamic range of 5 orders of magnitude (10–106 ng L1) have been demonstrated. Additionally, a competitive isotope-ratio precision of 0.1% RSD has been achieved with only a 6 s signal integration period. In addition to first figures of merit, this paper outlines technical considerations for the design of the ICP-DOFMS.« less

  12. Thermal noise limit for ultra-high vacuum noncontact atomic force microscopy

    PubMed Central

    Lübbe, Jannis; Temmen, Matthias; Rode, Sebastian; Rahe, Philipp; Kühnle, Angelika

    2013-01-01

    Summary The noise of the frequency-shift signal Δf in noncontact atomic force microscopy (NC-AFM) consists of cantilever thermal noise, tip–surface-interaction noise and instrumental noise from the detection and signal processing systems. We investigate how the displacement-noise spectral density d z at the input of the frequency demodulator propagates to the frequency-shift-noise spectral density d Δ f at the demodulator output in dependence of cantilever properties and settings of the signal processing electronics in the limit of a negligible tip–surface interaction and a measurement under ultrahigh-vacuum conditions. For a quantification of the noise figures, we calibrate the cantilever displacement signal and determine the transfer function of the signal-processing electronics. From the transfer function and the measured d z, we predict d Δ f for specific filter settings, a given level of detection-system noise spectral density d z ds and the cantilever-thermal-noise spectral density d z th. We find an excellent agreement between the calculated and measured values for d Δ f. Furthermore, we demonstrate that thermal noise in d Δ f, defining the ultimate limit in NC-AFM signal detection, can be kept low by a proper choice of the cantilever whereby its Q-factor should be given most attention. A system with a low-noise signal detection and a suitable cantilever, operated with appropriate filter and feedback-loop settings allows room temperature NC-AFM measurements at a low thermal-noise limit with a significant bandwidth. PMID:23400758

  13. Thermal noise limit for ultra-high vacuum noncontact atomic force microscopy.

    PubMed

    Lübbe, Jannis; Temmen, Matthias; Rode, Sebastian; Rahe, Philipp; Kühnle, Angelika; Reichling, Michael

    2013-01-01

    The noise of the frequency-shift signal Δf in noncontact atomic force microscopy (NC-AFM) consists of cantilever thermal noise, tip-surface-interaction noise and instrumental noise from the detection and signal processing systems. We investigate how the displacement-noise spectral density d(z) at the input of the frequency demodulator propagates to the frequency-shift-noise spectral density d(Δ) (f) at the demodulator output in dependence of cantilever properties and settings of the signal processing electronics in the limit of a negligible tip-surface interaction and a measurement under ultrahigh-vacuum conditions. For a quantification of the noise figures, we calibrate the cantilever displacement signal and determine the transfer function of the signal-processing electronics. From the transfer function and the measured d(z), we predict d(Δ) (f) for specific filter settings, a given level of detection-system noise spectral density d(z) (ds) and the cantilever-thermal-noise spectral density d(z) (th). We find an excellent agreement between the calculated and measured values for d(Δ) (f). Furthermore, we demonstrate that thermal noise in d(Δ) (f), defining the ultimate limit in NC-AFM signal detection, can be kept low by a proper choice of the cantilever whereby its Q-factor should be given most attention. A system with a low-noise signal detection and a suitable cantilever, operated with appropriate filter and feedback-loop settings allows room temperature NC-AFM measurements at a low thermal-noise limit with a significant bandwidth.

  14. Engine monitoring display study

    NASA Technical Reports Server (NTRS)

    Hornsby, Mary E.

    1992-01-01

    The current study is part of a larger NASA effort to develop displays for an engine-monitoring system to enable the crew to monitor engine parameter trends more effectively. The objective was to evaluate the operational utility of adding three types of information to the basic Boeing Engine Indicating and Crew Alerting System (EICAS) display formats: alphanumeric alerting messages for engine parameters whose values exceed caution or warning limits; alphanumeric messages to monitor engine parameters that deviate from expected values; and a graphic depiction of the range of expected values for current conditions. Ten training and line pilots each flew 15 simulated flight scenarios with five variants of the basic EICAS format; these variants included different combinations of the added information. The pilots detected engine problems more quickly when engine alerting messages were included in the display; adding a graphic depiction of the range of expected values did not affect detection speed. The pilots rated both types of alphanumeric messages (alert and monitor parameter) as more useful and easier to interpret than the graphic depiction. Integrating engine parameter messages into the EICAS alerting system appears to be both useful and preferred.

  15. Entanglement-Assisted Weak Value Amplification

    NASA Astrophysics Data System (ADS)

    Pang, Shengshi; Dressel, Justin; Brun, Todd A.

    2014-07-01

    Large weak values have been used to amplify the sensitivity of a linear response signal for detecting changes in a small parameter, which has also enabled a simple method for precise parameter estimation. However, producing a large weak value requires a low postselection probability for an ancilla degree of freedom, which limits the utility of the technique. We propose an improvement to this method that uses entanglement to increase the efficiency. We show that by entangling and postselecting n ancillas, the postselection probability can be increased by a factor of n while keeping the weak value fixed (compared to n uncorrelated attempts with one ancilla), which is the optimal scaling with n that is expected from quantum metrology. Furthermore, we show the surprising result that the quantum Fisher information about the detected parameter can be almost entirely preserved in the postselected state, which allows the sensitive estimation to approximately saturate the relevant quantum Cramér-Rao bound. To illustrate this protocol we provide simple quantum circuits that can be implemented using current experimental realizations of three entangled qubits.

  16. LP-LPA: A link influence-based label propagation algorithm for discovering community structures in networks

    NASA Astrophysics Data System (ADS)

    Berahmand, Kamal; Bouyer, Asgarali

    2018-03-01

    Community detection is an essential approach for analyzing the structural and functional properties of complex networks. Although many community detection algorithms have been recently presented, most of them are weak and limited in different ways. Label Propagation Algorithm (LPA) is a well-known and efficient community detection technique which is characterized by the merits of nearly-linear running time and easy implementation. However, LPA has some significant problems such as instability, randomness, and monster community detection. In this paper, an algorithm, namely node’s label influence policy for label propagation algorithm (LP-LPA) was proposed for detecting efficient community structures. LP-LPA measures link strength value for edges and nodes’ label influence value for nodes in a new label propagation strategy with preference on link strength and for initial nodes selection, avoid of random behavior in tiebreak states, and efficient updating order and rule update. These procedures can sort out the randomness issue in an original LPA and stabilize the discovered communities in all runs of the same network. Experiments on synthetic networks and a wide range of real-world social networks indicated that the proposed method achieves significant accuracy and high stability. Indeed, it can obviously solve monster community problem with regard to detecting communities in networks.

  17. Copper detection in the Asiatic clam Corbicula fluminea: optimum valve closure response.

    PubMed

    Tran, Damien; Fournier, Elodie; Durrieu, Gilles; Massabuau, Jean-Charles

    2004-02-25

    When exposed to a contaminant, bivalves close their shell as a protective strategy. The aim of the present study was to estimate the maximum expected dissolved copper sensitivity in the freshwater bivalve Corbicula fluminea using a new approach to determine their potential and limit to detect contaminants. To take into account the rate of spontaneous closures, we integrated stress problems associated with fixation by a valve in usual valvometers and the spontaneous rhythm associated with nycthemeral activity, to optimize the response in conditions where the probability of spontaneous closing was lowest. Moreover, we used an original system with impedance valvometry, using lightweight impedance electrodes, to study free-ranging animals in low stress conditions combined with an analytical approach describing dose-response curves by logistic regression, with valve closure reaction as a function of response time and concentration of contaminant. In C. fluminea, we estimated that copper concentrations > 4 microg/l (95% confidence interval (CI95%), 2.3-8.8 microg/l) must be detected within 5 h after Cu addition. Lower values could not be distinguished from background noise. The threshold values were 2.5 times lower than the values reported in the literature.

  18. Copper detection in the Asiatic clam Corbicula fluminea: optimum valve closure response.

    PubMed

    Tran, Damien; Fournier, Elodie; Durrieu, Gilles; Massabuau, Jean Charles

    2003-11-19

    When exposed to a contaminant, bivalves close their shell as a protective strategy. The aim of the present study was to estimate the maximum expected dissolved copper sensitivity in the freshwater bivalve Corbicula fluminea using a new approach to determine their potential and limit to detect contaminants. To take into account the rate of spontaneous closures, we integrated stress problems associated with fixation by a valve in usual valvometers and the spontaneous rhythm associated with nycthemeral activity, to optimize the response in conditions where the probability of spontaneous closing was lowest. Moreover, we used an original system with impedance valvometry, using lightweight impedance electrodes, to study free-ranging animals in low stress conditions combined with an analytical approach describing dose-response curves by logistic regression, with valve closure reaction as a function of response time and concentration of contaminant. In C. fluminea, we estimated that copper concentrations >4 microg/l (95% confidence interval (CI(95%)), 2.3-8.8 microg/l) must be detected within 5 h after Cu addition. Lower values could not be distinguished from background noise. The threshold values were 2.5 times higher than the values reported in the literature.

  19. Metal-organic gel enhanced fluorescence anisotropy for sensitive detection of prostate specific antigen

    NASA Astrophysics Data System (ADS)

    Zhao, Ting Ting; Peng, Zhe Wei; Yuan, Dan; Zhen, Shu Jun; Huang, Cheng Zhi; Li, Yuan Fang

    2018-03-01

    In this contribution, we demonstrated that Cu-based metal-organic gel (Cu-MOG) was able to serve as a novel amplification platform for fluorescence anisotropy (FA) assay for the first time, which was confirmed by the sensitive detection of a common cancer biomarker, prostate specific antigen (PSA). The dye-labeled probe aptamer (PA) product was adsorbed onto the benzimidazole derivative-containing Cu-MOG via electrostatic incorporation and strong π-π stacking interactions, which significantly increased the FA value due to the enlargement of the molecular volume of the PA/Cu-MOG complex. With the introduction of target PSA, the FA value was obviously decreased on account of the specific recognition between PSA and PA which resulted in the detachment of PA from the surface of MOG. The linear range was from 0.5-8 ng/mL, with a detection limit of 0.33 ng/mL. Our work has thus helped to demonstrate promising application of MOG material in the fields of biomolecules analysis and disease diagnosis.

  20. Sensitivity improvement of an electrical sensor achieved by control of biomolecules based on the negative dielectrophoretic force.

    PubMed

    Kim, Hye Jin; Kim, Jinsik; Yoo, Yong Kyoung; Lee, Jeong Hoon; Park, Jung Ho; Hwang, Kyo Seon

    2016-11-15

    Effective control of nano-scale biomolecules can enhance the sensitivity and limit of detection of an interdigitated microelectrode (IME) sensor. Manipulation of the biomolecules by dielectrophoresis (DEP), especially the negative DEP (nDEP) force, so that they are trapped between electrodes (sensing regions) was predicted to increase the binding efficiency of the antibody and target molecules, leading to a more effective reaction. To prove this concept, amyloid beta 42 (Aβ42) and prostate specific antigen (PSA) protein were respectively trapped between the sensing region owing to the nDEP force under 5V and 0.05V, which was verified with COMSOL simulation. Using the simulation value, the resistance change (ΔR/Rb) of the IME sensor from the specific antibody-antigen reaction of the two biomolecules and the change in fluorescence intensity were compared in the reference (pDEP) and nDEP conditions. The ΔR/Rb value improved by about 2-fold and 1.66-fold with nDEP compared to the reference condition with various protein concentrations, and these increases were confirmed with fluorescence imaging. Overall, nDEP enhanced the detection sensitivity for Aβ42 and PSA by 128% and 258%, respectively, and the limit of detection improved by up to 2-orders of magnitude. These results prove that DEP can improve the biosensor's performance. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Testing chirality of primordial gravitational waves with Planck and future CMB data: no hope from angular power spectra

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gerbino, Martina; Gruppuso, Alessandro; Natoli, Paolo

    We use the 2015 Planck likelihood in combination with the Bicep2/Keck likelihood (BKP and BK14) to constrain the chirality, χ, of primordial gravitational waves in a scale-invariant scenario. In this framework, the parameter χ enters theory always coupled to the tensor-to-scalar ratio, r , e.g. in combination of the form χ ⋅ r . Thus, the capability to detect χ critically depends on the value of r . We find that with present data sets χ is de facto unconstrained. We also provide forecasts for χ from future CMB experiments, including COrE+, exploring several fiducial values of r . Wemore » find that the current limit on r is tight enough to disfavor a neat detection of χ. For example, in the unlikely case in which r ∼0.1(0.05), the maximal chirality case, i.e. χ = ±1, could be detected with a significance of ∼2.5(1.5)σ at best. We conclude that the two-point statistics at the basis of CMB likelihood functions is currently unable to constrain chirality and may only provide weak limits on χ in the most optimistic scenarios. Hence, it is crucial to investigate the use of other observables, e.g. provided by higher order statistics, to constrain these kinds of parity violating theories with the CMB.« less

  2. Point-of-care testing for streptomycin based on aptamer recognizing and digital image colorimetry by smartphone.

    PubMed

    Lin, Bixia; Yu, Ying; Cao, Yujuan; Guo, Manli; Zhu, Debin; Dai, Jiaxing; Zheng, Minshi

    2018-02-15

    The rapid detection of antibiotic residual in everyday life is very important for food safety. In order to realize the on-site and visual detection of antibiotic, a POCT method was established by using digital image colorimetry based on smartphone. Streptomycin was taken as the analyte model of antibiotics, streptomycin aptamer preferentially recognized analyte, and the excess aptamer hybridized with the complementary DNA to form the dsDNA. SYBR Green I combined with the dsDNA and then emitted obvious green fluorescence, thus the fluorescence intensity decreased with the increasing of streptomycin concentration. Then a smartphone-based device was constructed as the fluorescence readout. The smartphone camera acquired the images of the fluorescence derived from the samples, and the Touch Color APP installed in smartphone read out the RGB values of the images. There was a linear relationship between the G values and the streptomycin concentrations in the range of 0.1-100µM. The detection limit was 94nM, which was lower than the maximum residue limit defined by World Health Organization. The POCT method was applied for determining streptomycin in chicken and milk samples with recoveries in 94.1-110%. This method had the advantages of good selectivity, simple operation and on-site visualization. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Flavoring exposure in food manufacturing.

    PubMed

    Curwin, Brian D; Deddens, Jim A; McKernan, Lauralynn T

    2015-05-01

    Flavorings are substances that alter or enhance the taste of food. Workers in the food-manufacturing industry, where flavorings are added to many products, may be exposed to any number of flavoring compounds. Although thousands of flavoring substances are in use, little is known about most of these in terms of worker health effects, and few have occupational exposure guidelines. Exposure assessment surveys were conducted at nine food production facilities and one flavor manufacturer where a total of 105 area and 74 personal samples were collected for 13 flavoring compounds including five ketones, five aldehydes, and three acids. The majority of the samples were below the limit of detection (LOD) for most compounds. Diacetyl had eight area and four personal samples above the LOD, whereas 2,3-pentanedione had three area samples above the LOD. The detectable values ranged from 25-3124 ppb and 15-172 ppb for diacetyl and 2,3-pentanedione respectively. These values exceed the proposed National Institute for Occupational Safety and Health (NIOSH) recommended exposure limit for these compounds. The aldehydes had the most detectable samples, with each of them having >50% of the samples above the LOD. Acetaldehyde had all but two samples above the LOD, however, these samples were below the OSHA PEL. It appears that in the food-manufacturing facilities surveyed here, exposure to the ketones occurs infrequently, however levels above the proposed NIOSH REL were found. Conversely, aldehyde exposure appears to be ubiquitous.

  4. Investigation of the response characteristics of OSL albedo neutron dosimeters in a 241AmBe reference neutron field

    NASA Astrophysics Data System (ADS)

    Liamsuwan, T.; Wonglee, S.; Channuie, J.; Esoa, J.; Monthonwattana, S.

    2017-06-01

    The objective of this work was to systematically investigate the response characteristics of optically stimulated luminescence Albedo neutron (OSLN) dosimeters to ensure reliable personal dosimetry service provided by Thailand Institute of Nuclear Technology (TINT). Several batches of InLight® OSLN dosimeters were irradiated in a reference neutron field generated by the in-house 241AmBe neutron irradiator. The OSL signals were typically measured 24 hours after irradiation using the InLight® Auto 200 Reader. Based on known values of delivered neutron dose equivalent, the reading correction factor to be used by the reader was evaluated. Subsequently, batch homogeneity, dose linearity, lower limit of detection and fading of the OSLN dosimeters were examined. Batch homogeneity was evaluated to be 0.12 ± 0.05. The neutron dose response exhibited a linear relationship (R2=0.9974) within the detectable neutron dose equivalent range under test (0.4-3 mSv). For this neutron field, the lower limit of detection was between 0.2 and 0.4 mSv. Over different post-irradiation storage times of up to 180 days, the readings fluctuated within ±5%. Personal dosimetry based on the investigated OSLN dosimeter is considered to be reliable under similar neutron exposure conditions, i.e. similar neutron energy spectra and dose equivalent values.

  5. Circannual and circadian rhythms in the concentration of corticosterone in the plasma of the edible frog (Rana esculenta L.).

    PubMed

    Dupont, W; Bourgeois, P; Reinberg, A; Vaillant, R

    1979-01-01

    For a period of 21 months between May 1974 and September 1976, circadian variations in the plasma concentration of corticosterone were studied by competitive protein-binding techniques in mature male and female edible frogs living in their natural environment. Blood samples were taken from 8 to 12 frogs six times daily and conventional and cosinor methods were used for statistical analysis. Circadian rhythms were not detected during February and March (time of hibernation). Circannual rhythms were detected in three parameters of the circadian rhythm. The mean concentration of corticosterone over a 24 h period (24 h mean) reached a peak on 1 May (between 15 April and 15 May; 95% limits of confidence); the annual mean value of the 24 h means was 1.97 +/- 0.25 (S.E.M.) microgram/100 ml, with an amplitude of 0.66 microgram/100 ml (0.53--0.79 microgram/100 ml; 95% limits of confidence). Circadian variations in the concentration of corticosterone were largest in May (peak of reproductive activity). The times at which the peak concentration of corticosterone occurred showed circannual variations: peak values were detected around 24.00 h in May, 19.00 h in July and 08.00 h in November. Both circadian and circannual variations have therefore been demonstrated in an endocrine function of an amphibian in its natural habitat.

  6. Trends in bromide wet deposition concentrations in the contiguous United States, 2001-2016.

    PubMed

    Wetherbee, Gregory A; Lehmann, Christopher M B; Kerschner, Brian M; Ludtke, Amy S; Green, Lee A; Rhodes, Mark F

    2018-02-01

    Bromide (Br - ) and other solute concentration data from wet deposition samples collected and analyzed by the National Atmospheric Deposition Program (NADP) from 2001 to 2016, were statistically analyzed for trends both geographically and temporally by precipitation type. Analysis was limited to NADP sites in the contiguous 48 United States. The Br - concentrations for this time period had a high number of values censored at the detection limits with greater than 86 percent of sample concentrations below analytical detection. Bromide was more frequently detected at NADP sites in coastal regions. Analysis using specialized statistical techniques for censored data revealed that Br - concentrations varied by precipitation type with higher concentrations usually observed in liquid versus precipitation containing snow. Negative temporal trends in Br - wet deposition concentrations were observed at a majority of NADP sites; approximately 25 percent of these trend values were statistically significant at less than 0.05 to 0.10 significance levels. Potential causes for the negative trends were explored, including annual and seasonal changes in precipitation depth, reduced emissions of methyl bromide (CH 3 Br) from coastal wetlands, and declining industrial use of bromine compounds. The results indicate that Br - in non-coastal wet-deposition comes mainly from long-range transport, not local sources. Correlations between Br - , chloride, and nitrate concentrations also were evaluated. Published by Elsevier Ltd.

  7. A novel quadruplex real-time PCR method for simultaneous detection of Cry2Ae and two genetically modified cotton events (GHB119 and T304-40).

    PubMed

    Li, Xiang; Wang, Xiuxiu; Yang, Jielin; Liu, Yueming; He, Yuping; Pan, Liangwen

    2014-05-16

    To date, over 150 genetically modified (GM) crops are widely cultivated. To comply with regulations developed for genetically modified organisms (GMOs), including labeling policies, many detection methods for GMO identification and quantification have been developed. To detect the entrance and exit of unauthorized GM crop events in China, we developed a novel quadruplex real-time PCR method for simultaneous detection and quantification of GM cotton events GHB119 and T304-40 in cotton-derived products (based on the 5'-flanking sequence) and the insect-resistance gene Cry2Ae. The limit of detection was 10 copies for GHB119 and Cry2Ae and 25 copies for T304-40. The limit of quantification was 25 copies for GHB119 and Cry2Ae and 50 copies for T304-40. Moreover, low bias and acceptable standard deviation and relative standard deviation values were obtained in quantification analysis of six blind samples containing different GHB119 and T304-40 ingredients. The developed quadruplex quantitative method could be used for quantitative detection of two GM cotton events (GHB119 and T304-40) and Cry2Ae gene ingredient in cotton derived products.

  8. A novel quadruplex real-time PCR method for simultaneous detection of Cry2Ae and two genetically modified cotton events (GHB119 and T304-40)

    PubMed Central

    2014-01-01

    Background To date, over 150 genetically modified (GM) crops are widely cultivated. To comply with regulations developed for genetically modified organisms (GMOs), including labeling policies, many detection methods for GMO identification and quantification have been developed. Results To detect the entrance and exit of unauthorized GM crop events in China, we developed a novel quadruplex real-time PCR method for simultaneous detection and quantification of GM cotton events GHB119 and T304-40 in cotton-derived products (based on the 5′-flanking sequence) and the insect-resistance gene Cry2Ae. The limit of detection was 10 copies for GHB119 and Cry2Ae and 25 copies for T304-40. The limit of quantification was 25 copies for GHB119 and Cry2Ae and 50 copies for T304-40. Moreover, low bias and acceptable standard deviation and relative standard deviation values were obtained in quantification analysis of six blind samples containing different GHB119 and T304-40 ingredients. Conclusions The developed quadruplex quantitative method could be used for quantitative detection of two GM cotton events (GHB119 and T304-40) and Cry2Ae gene ingredient in cotton derived products. PMID:24884946

  9. Detection of Fusarium verticillioides by PCR-ELISA based on FUM21 gene.

    PubMed

    Omori, Aline Myuki; Ono, Elisabete Yurie Sataque; Bordini, Jaqueline Gozzi; Hirozawa, Melissa Tiemi; Fungaro, Maria Helena Pelegrinelli; Ono, Mario Augusto

    2018-08-01

    Fusarium verticillioides is a primary corn pathogen and fumonisin producer which is associated with toxic effects in humans and animals. The traditional methods for detection of fungal contamination based on morphological characteristics are time-consuming and show low sensitivity and specificity. Therefore, the objective of this study was to develop a PCR-ELISA based on the FUM21 gene for F. verticillioides detection. The DNA of the F. verticillioides, Fusarium sp., Aspergillus sp. and Penicillium sp. isolates was analyzed by conventional PCR and PCR-ELISA to determine the specificity. The PCR-ELISA was specific to F. verticillioides isolates, showed a 2.5 pg detection limit and was 100-fold more sensitive than conventional PCR. In corn samples inoculated with F. verticillioides conidia, the detection limit of the PCR-ELISA was 1 × 10 4 conidia/g and was also 100-fold more sensitive than conventional PCR. Naturally contaminated corn samples were analyzed by PCR-ELISA based on the FUM21 gene and PCR-ELISA absorbance values correlated positively (p < 0.05) with Fusarium sp. counts (CFU/g). These results suggest that the PCR-ELISA developed in this study can be useful for F. verticillioides detection in corn samples. Copyright © 2018 Elsevier Ltd. All rights reserved.

  10. A gain and bandwidth enhanced transimpedance preamplifier for Fourier-transform ion cyclotron resonance mass spectrometry

    NASA Astrophysics Data System (ADS)

    Lin, Tzu-Yung; Green, Roger J.; O'Connor, Peter B.

    2011-12-01

    The nature of the ion signal from a 12-T Fourier-transform ion cyclotron resonance mass spectrometer and the electronic noise were studied to further understand the electronic detection limit. At minimal cost, a new transimpedance preamplifier was designed, computer simulated, built, and tested. The preamplifier design pushes the electronic signal-to-noise performance at room temperature to the limit, because of its enhanced tolerance of the capacitance of the detection device, lower intrinsic noise, and larger flat mid-band gain (input current noise spectral density of around 1 pA/sqrt{Hz} when the transimpedance is about 85 dBΩ). The designed preamplifier has a bandwidth of ˜3 kHz to 10 MHz, which corresponds to the mass-to-charge ratio, m/z, of approximately 18 to 61 k at 12 T. The transimpedance and the bandwidth can be easily adjusted by changing the value of passive components. The feedback limitation of the circuit is discussed. With the maximum possible transimpedance of 5.3 MΩ when using an 0402 surface mount resistor, the preamplifier was estimated to be able to detect ˜110 charges in a single scan.

  11. A gain and bandwidth enhanced transimpedance preamplifier for Fourier-transform ion cyclotron resonance mass spectrometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lin, Tzu-Yung; Green, Roger J.; O'Connor, Peter B.

    2011-12-15

    The nature of the ion signal from a 12-T Fourier-transform ion cyclotron resonance mass spectrometer and the electronic noise were studied to further understand the electronic detection limit. At minimal cost, a new transimpedance preamplifier was designed, computer simulated, built, and tested. The preamplifier design pushes the electronic signal-to-noise performance at room temperature to the limit, because of its enhanced tolerance of the capacitance of the detection device, lower intrinsic noise, and larger flat mid-band gain (input current noise spectral density of around 1 pA/{radical}(Hz) when the transimpedance is about 85 dB{Omega}). The designed preamplifier has a bandwidth of {approx}3more » kHz to 10 MHz, which corresponds to the mass-to-charge ratio, m/z, of approximately 18 to 61 k at 12 T. The transimpedance and the bandwidth can be easily adjusted by changing the value of passive components. The feedback limitation of the circuit is discussed. With the maximum possible transimpedance of 5.3 M{Omega} when using an 0402 surface mount resistor, the preamplifier was estimated to be able to detect {approx}110 charges in a single scan.« less

  12. Evaluating quality of adhesive joints in glass-fiber plastic piping by using active thermal NDT

    NASA Astrophysics Data System (ADS)

    Grosso, M.; Marinho, C. A.; Nesteruk, D. A.; Rebello, J. M.; Soares, S. D.; Vavilov, V. P.

    2013-05-01

    GRP-type composites (Glass-fibre Reinforced Plastics) have been continuously employed in the oil industry in recent years, often on platforms, especially in pipes for water or oil under moderate temperatures. In this case, the pipes are usually connected through adhesive joints and, consequently, the detection of defects in these joints, as areas without adhesive or adhesive failure (disbonding), gains great importance. One-sided inspection on the joint surface (front side) is a challenging task because the material thickness easily exceeds 10 mm that is far beyond the limits of the capacity of thermography applied to GRP inspection, as confirmed by the experience. Detection limits have been evaluated both theoretically and experimentally as a function of outer wall thickness and defect lateral size. The 3D modeling was accomplished by using the ThermoCalc-6L software. The experimental unit consisted of a FLIR SC640 and NEC TH- 9100 IR imagers and some home-made heaters with the power from 1,5 to 30 kW. The results obtained by applying pulsed heating have demonstrated that the inspection efficiency is strongly dependent on the outer wall thickness with a value of about 8 mm being a detection limit.

  13. Influence of the vibro-acoustic sensor position on cavitation detection in a Kaplan turbine

    NASA Astrophysics Data System (ADS)

    Schmidt, H.; Kirschner, O.; Riedelbauch, S.; Necker, J.; Kopf, E.; Rieg, M.; Arantes, G.; Wessiak, M.; Mayrhuber, J.

    2014-03-01

    Hydraulic turbines can be operated close to the limits of the operating range to meet the demand of the grid. When operated close to the limits, the risk increases that cavitation phenomena may occur at the runner and / or at the guide vanes of the turbine. Cavitation in a hydraulic turbine can cause material erosion on the runner and other turbine parts and reduce the durability of the machine leading to required outage time and related repair costs. Therefore it is important to get reliable information about the appearance of cavitation during prototype operation. In this experimental investigation the high frequency acoustic emissions and vibrations were measured at 20 operating points with different cavitation behaviour at different positions in a large prototype Kaplan turbine. The main goal was a comparison of the measured signals at different sensor positions to identify the sensitivity of the location for cavitation detection. The measured signals were analysed statistically and specific values were derived. Based on the measured signals, it is possible to confirm the cavitation limit of the examined turbine. The result of the investigation shows that the position of the sensors has a significant influence on the detection of cavitation.

  14. Experimental investigation of geologically produced antineutrinos with KamLAND.

    PubMed

    Araki, T; Enomoto, S; Furuno, K; Gando, Y; Ichimura, K; Ikeda, H; Inoue, K; Kishimoto, Y; Koga, M; Koseki, Y; Maeda, T; Mitsui, T; Motoki, M; Nakajima, K; Ogawa, H; Ogawa, M; Owada, K; Ricol, J-S; Shimizu, I; Shirai, J; Suekane, F; Suzuki, A; Tada, K; Takeuchi, S; Tamae, K; Tsuda, Y; Watanabe, H; Busenitz, J; Classen, T; Djurcic, Z; Keefer, G; Leonard, D; Piepke, A; Yakushev, E; Berger, B E; Chan, Y D; Decowski, M P; Dwyer, D A; Freedman, S J; Fujikawa, B K; Goldman, J; Gray, F; Heeger, K M; Hsu, L; Lesko, K T; Luk, K-B; Murayama, H; O'Donnell, T; Poon, A W P; Steiner, H M; Winslow, L A; Mauger, C; McKeown, R D; Vogel, P; Lane, C E; Miletic, T; Guillian, G; Learned, J G; Maricic, J; Matsuno, S; Pakvasa, S; Horton-Smith, G A; Dazeley, S; Hatakeyama, S; Rojas, A; Svoboda, R; Dieterle, B D; Detwiler, J; Gratta, G; Ishii, K; Tolich, N; Uchida, Y; Batygov, M; Bugg, W; Efremenko, Y; Kamyshkov, Y; Kozlov, A; Nakamura, Y; Karwowski, H J; Markoff, D M; Nakamura, K; Rohm, R M; Tornow, W; Wendell, R; Chen, M-J; Wang, Y-F; Piquemal, F

    2005-07-28

    The detection of electron antineutrinos produced by natural radioactivity in the Earth could yield important geophysical information. The Kamioka liquid scintillator antineutrino detector (KamLAND) has the sensitivity to detect electron antineutrinos produced by the decay of 238U and 232Th within the Earth. Earth composition models suggest that the radiogenic power from these isotope decays is 16 TW, approximately half of the total measured heat dissipation rate from the Earth. Here we present results from a search for geoneutrinos with KamLAND. Assuming a Th/U mass concentration ratio of 3.9, the 90 per cent confidence interval for the total number of geoneutrinos detected is 4.5 to 54.2. This result is consistent with the central value of 19 predicted by geophysical models. Although our present data have limited statistical power, they nevertheless provide by direct means an upper limit (60 TW) for the radiogenic power of U and Th in the Earth, a quantity that is currently poorly constrained.

  15. Analysis of bakery products by laser-induced breakdown spectroscopy.

    PubMed

    Bilge, Gonca; Boyacı, İsmail Hakkı; Eseller, Kemal Efe; Tamer, Uğur; Çakır, Serhat

    2015-08-15

    In this study, we focused on the detection of Na in bakery products by using laser-induced breakdown spectroscopy (LIBS) as a quick and simple method. LIBS experiments were performed to examine the Na at 589 nm to quantify NaCl. A series of standard bread sample pellets containing various concentrations of NaCl (0.025-3.5%) were used to construct the calibration curves and to determine the detection limits of the measurements. Calibration graphs were drawn to indicate functions of NaCl and Na concentrations, which showed good linearity in the range of 0.025-3.5% NaCl and 0.01-1.4% Na concentrations with correlation coefficients (R(2)) values greater than 0.98 and 0.96. The obtained detection limits for NaCl and Na were 175 and 69 ppm, respectively. Performed experimental studies showed that LIBS is a convenient method for commercial bakery products to quantify NaCl concentrations as a rapid and in situ technique. Copyright © 2015 Elsevier Ltd. All rights reserved.

  16. Determination of patulin in commercial apple juice by micellar electrokinetic chromatography.

    PubMed

    Murillo, M; González-Peñas, E; Amézqueta, S

    2008-01-01

    A novel and validated micellar electrokinetic capillary chromatography (MEKC) method using ultraviolet detection (UV) has been applied to the quantitative analysis of patulin (PAT) in commercial apple juice. Patulin was extracted from samples with an ethylacetate solution. The micellar electrokinetic capillary chromatography (MECK) parameters studied for method optimization were buffer composition, voltage, temperature, and a separation between PAT and 5-hydroxymethylfurfural (HMF) (main interference in apple juice PAT analysis) peaks until reaching baseline. The method passes a series of validation tests including selectivity, linearity, limit of detection and quantification (0.7 and 2.5 microgL(-1), respectively), precision (within and between-day variability) and recovery (80.2% RSD=4%), accuracy, and robustness. This method was successfully applied to the measurement of 20 apple juice samples obtained from different supermarkets. One hundred percent of the samples were contaminated with a level greater than the limit of detection, with mean and median values of 41.3 and 35.7 microgL(-1), respectively.

  17. Determination of seven flavonoids in Ixeridium gracile (DC.) Shih by high-performance liquid chromatography.

    PubMed

    Chen, Juan; Ma, Xue-Mei; Shi, Yan-Ping

    2009-01-01

    A high-performance liquid chromatographic technique coupled with photodiode array detection was proposed for the simultaneous determination of 7 flavonoids, i.e., quercetin, kaempferol, 7-hydroxyflavanone, 7-methoxyflavanone, 2',4'-dihydroxychalcone, 2',4'-dihydroxydihydrochalcone, and 7,2'-dihydroxy-3', 4'-dimethoxyisoflavane, in extracts of the plant Ixeridium gracile. Optimum separation was obtained by using a reversed-phase C18 method. Because of the different UV characteristics of these components, 5 detection wavelengths were used for the quantitative analysis. All of the flavonoids showed good linearity (r > 0.9999). The limit of detection and limit of quantitation values for the analytes ranged from 0.06 to 0.46 microg/mL and from 0.18 to 1.48 microg/mL, respectively. The method was validated by evaluating repeatability, precision, stability, and accuracy. Five different extraction and purification procedures were investigated for preparation of the sample solution. The optimized method was applied to the determination of flavonoids in I. gracile and was found to be efficient.

  18. Methyl tert-butyl ether (MTBE) in finished drinking water in Germany.

    PubMed

    Kolb, Axel; Püttmann, Wilhelm

    2006-03-01

    In the present study 83 finished drinking water samples from 50 cities in Germany were analyzed for methyl tert-butyl ether (MTBE) content with a detection limit of 10 ng/L. The detection frequency was 46% and the concentrations ranged between 17 and 712 ng/L. Highest concentrations were found in the community water systems (CWSs) of Leuna and Spergau in Saxony-Anhalt. These CWSs are supplied with water possibly affected by MTBE contaminated groundwater. MTBE was detected at concentrations lower than 100 ng/L in drinking water supplied by CWSs using bank filtered water from Rhine and Main Rivers. The results from Leuna and Spergau show that large groundwater contaminations in the vicinity of CWSs pose the highest risk for MTBE contamination in drinking water. CWSs using bank filtered water from Rhine and Main Rivers are susceptible to low MTBE contaminations in finished drinking water. All measured MTBE concentrations were below proposed limit values for drinking water.

  19. Installation Restoration Program. Remedial Investigation Report: Minnesota Air National Guard Base Duluth International Airport, Duluth, Minnesota. Volume 6

    DTIC Science & Technology

    1990-01-01

    reporting limit. Acceptable RPD in this case is defined as duplicate values within one detection limit of each other. I I I I I I i I i 2567I88-A1...analysis shois the :aboratory to be in ccn:rol. Results for Sa:Dle No. 88092.739 are reported on a wet weight basis, since percen:age moisture was...describes the remedial actions performed on sites confirmed to contain hazardous waste contamination which endangers the human health. The actions

  20. Asbestos Air Monitoring Results at Eleven Family Housing Areas throughout the United States.

    DTIC Science & Technology

    1991-05-23

    limits varied depending on sampling volumes and grid openings scanned. Therefore, the detection limits presented in the results summary tables vary...1 f/10 grid squares) (855 mm 2) (1 liter) = 3054 liters (0.005 f/cc) (0.0056 mm 2) (1000 cc) Where: * 1 f/10 grid squares (the maximum recommended...diameter filter. * 0.0056 mm 2 is the area of each grid square (75 /Jm per side) in a 200 mesh electron microscope grid . This value will vary from 0.0056

  1. Visualization of hospital cleanliness in three Japanese hospitals with a tendency toward long-term care

    PubMed Central

    2014-01-01

    Background Hospital cleanliness in hospitals with a tendency toward long-term care in Japan remains unevaluated. We therefore visualized hospital cleanliness in Japan over a 2-month period by two distinct popular methods: ATP bioluminescence (ATP method) and the standard stamp agar method (stamp method). Methods The surfaces of 752 sites within nurse and patient areas in three hospitals located in a central area of Sapporo, Japan were evaluated by the ATP and stamp methods, and each surface was sampled 8 times in 2 months. These areas were located in different ward units (Internal Medicine, Surgery, and Obstetrics and Gynecology). Detection limits for the ATP and stamp methods were determined by spike experiments with a diluted bacterial solution and a wipe test on student tables not in use during winter vacation, respectively. Values were expressed as the fold change over the detection limit, and a sample with a value higher than the detection limit by either method was defined as positive. Results The detection limits were determined to be 127 relative light units (RLU) per 100 cm2 for the ATP method and 5.3 colony-forming units (CFU) per 10 cm2 for the stamp method. The positive frequency of the ATP and stamp methods was 59.8% (450/752) and 47.7% (359/752), respectively, although no significant difference in the positive frequency among the hospitals was seen. Both methods revealed the presence of a wide range of organic contamination spread via hand touching, including microbial contamination, with a preponderance on the entrance floor and in patient rooms. Interestingly, the data of both methods indicated considerable variability regardless of daily visual assessment with usual wiping, and positive surfaces were irregularly seen. Nurse areas were relatively cleaner than patient areas. Finally, there was no significant correlation between the number of patients or medical personnel in the hospital and organic or microbiological contamination. Conclusions Ongoing daily hospital cleanliness is not sufficient in Japanese hospitals with a tendency toward long-term care. PMID:24593868

  2. Visualization of hospital cleanliness in three Japanese hospitals with a tendency toward long-term care.

    PubMed

    Watanabe, Reina; Shimoda, Tomoko; Yano, Rika; Hayashi, Yasuhiro; Nakamura, Shinji; Matsuo, Junji; Yamaguchi, Hiroyuki

    2014-03-04

    Hospital cleanliness in hospitals with a tendency toward long-term care in Japan remains unevaluated. We therefore visualized hospital cleanliness in Japan over a 2-month period by two distinct popular methods: ATP bioluminescence (ATP method) and the standard stamp agar method (stamp method). The surfaces of 752 sites within nurse and patient areas in three hospitals located in a central area of Sapporo, Japan were evaluated by the ATP and stamp methods, and each surface was sampled 8 times in 2 months. These areas were located in different ward units (Internal Medicine, Surgery, and Obstetrics and Gynecology). Detection limits for the ATP and stamp methods were determined by spike experiments with a diluted bacterial solution and a wipe test on student tables not in use during winter vacation, respectively. Values were expressed as the fold change over the detection limit, and a sample with a value higher than the detection limit by either method was defined as positive. The detection limits were determined to be 127 relative light units (RLU) per 100 cm2 for the ATP method and 5.3 colony-forming units (CFU) per 10 cm2 for the stamp method. The positive frequency of the ATP and stamp methods was 59.8% (450/752) and 47.7% (359/752), respectively, although no significant difference in the positive frequency among the hospitals was seen. Both methods revealed the presence of a wide range of organic contamination spread via hand touching, including microbial contamination, with a preponderance on the entrance floor and in patient rooms. Interestingly, the data of both methods indicated considerable variability regardless of daily visual assessment with usual wiping, and positive surfaces were irregularly seen. Nurse areas were relatively cleaner than patient areas. Finally, there was no significant correlation between the number of patients or medical personnel in the hospital and organic or microbiological contamination. Ongoing daily hospital cleanliness is not sufficient in Japanese hospitals with a tendency toward long-term care.

  3. Quantile regression for the statistical analysis of immunological data with many non-detects.

    PubMed

    Eilers, Paul H C; Röder, Esther; Savelkoul, Huub F J; van Wijk, Roy Gerth

    2012-07-07

    Immunological parameters are hard to measure. A well-known problem is the occurrence of values below the detection limit, the non-detects. Non-detects are a nuisance, because classical statistical analyses, like ANOVA and regression, cannot be applied. The more advanced statistical techniques currently available for the analysis of datasets with non-detects can only be used if a small percentage of the data are non-detects. Quantile regression, a generalization of percentiles to regression models, models the median or higher percentiles and tolerates very high numbers of non-detects. We present a non-technical introduction and illustrate it with an implementation to real data from a clinical trial. We show that by using quantile regression, groups can be compared and that meaningful linear trends can be computed, even if more than half of the data consists of non-detects. Quantile regression is a valuable addition to the statistical methods that can be used for the analysis of immunological datasets with non-detects.

  4. Limits on the LyC signal from z ~ 3 sources with secure redshift and HST coverage in the E-CDFS field

    NASA Astrophysics Data System (ADS)

    Guaita, L.; Pentericci, L.; Grazian, A.; Vanzella, E.; Nonino, M.; Giavalisco, M.; Zamorani, G.; Bongiorno, A.; Cassata, P.; Castellano, M.; Garilli, B.; Gawiser, E.; Le Brun, V.; Le Fèvre, O.; Lemaux, B. C.; Maccagni, D.; Merlin, E.; Santini, P.; Tasca, L. A. M.; Thomas, R.; Zucca, E.; De Barros, S.; Hathi, N. P.; Amorin, R.; Bardelli, S.; Fontana, A.

    2016-03-01

    Context. Determining the strength of the Lyman continuum (LyC) and the fraction of LyC escape have implications for the properties of the emitting sources at any redshift, but also for the re-ionization of the Universe at z > 6. Aims: We aim to measure the LyC signal from a sample of sources in the Chandra deep field south. We collect star-forming galaxies (SFGs) and active galactic nuclei (AGN) with accurate spectroscopic redshifts, for which Hubble Space Telescope (HST) coverage and multi-wavelength photometry are available. Methods: We selected a sample of about 200 sources at z ~ 3. Taking advantage of HST resolution, we applied a careful cleaning procedure and rejected sources showing nearby clumps with different colours, which could be lower-z interlopers. Our clean sample consisted of 86 SFGs (including 19 narrow-band selected Lyα emitters) and 8 AGN (including 6 detected in X-rays). We measured the LyC flux from aperture photometry in four narrow-band filters covering wavelengths below a 912 Å rest frame (3.11 < z < 3.53). We estimated the ratio between ionizing (LyC flux) and 1400 Å non-ionizing emissions for AGN and galaxies. Results: By running population synthesis models, we assume an average intrinsic Lν(1400 Å)/Lν(900 Å) ratio of 5 as the representative value for our sample. With this value and an average treatment of the lines of sight of the inter-galactic medium, we estimate the LyC escape fraction relative to the intrinsic value (fescrel(LyC)). We do not directly detect ionizing radiation from any individual SFG, but we are able to set a 1(2)σ upper limit of fescrel(LyC) < 12(24)%. This result is consistent with other non-detections published in the literature. No meaningful limits can be calculated for the sub-sample of Lyα emitters. We obtain one significant direct detection for an AGN at z = 3.46, with fescrel(LyC) = (72 ± 18)%. Conclusions: Our upper limit on fescrel(LyC) implies that the SFGs studied here do not present either the physical properties or the geometric conditions suitable for efficient LyC-photon escape. Based on data obtained with the European Southern Observatory Very Large Telescope, Paranal, Chile, under Programs 170.A-0788, 074.A-0709, 171.A-3045, 275.A-5060, and 185.A-0791.

  5. Determination of alternative preservatives in cosmetic products by chromophoric derivatization followed by vortex-assisted liquid-liquid semimicroextraction and liquid chromatography.

    PubMed

    Miralles, Pablo; Vrouvaki, Ilianna; Chisvert, Alberto; Salvador, Amparo

    2016-07-01

    An analytical method for the simultaneous determination of phenethyl alcohol, methylpropanediol, phenylpropanol, caprylyl glycol, and ethylhexylglycerin, which are used as alternative preservatives in cosmetic products, has been developed. The method is based on liquid chromatography with UV spectrophotometric detection after chromophoric derivatization with benzoyl chloride and vortex-assisted liquid-liquid semimicroextraction. Different chromatographic parameters, derivatization conditions, and sample preparation variables were studied. Under optimized conditions, the limits of detection values for the analytes ranged from 0.02 to 0.06µgmL(-1). The method was validated with good recovery values (84-118%) and precision values (3.9-9.5%). It was successfully applied to 10 commercially available cosmetic samples. The good analytical features of the proposed method besides of its environmentally-friendly characteristics, make it useful to carry out the quality control of cosmetic products containing the target compounds as preservative agents. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Value of Different Assays for Detection of Human Cytomegalovirus (HCMV) in Predicting the Development of HCMV Disease in Human Immunodeficiency Virus-Infected Patients

    PubMed Central

    Blank, Brian S. N.; Meenhorst, Pieter L.; Mulder, Jan Willem; Weverling, Gerrit Jan; Putter, Hein; Pauw, Wouter; van Dijk, Willemien C.; Smits, Paul; Lie-A-Ling, Sonja; Reiss, Peter; Lange, Joep M. A.

    2000-01-01

    In the present prospective study, five blood tests for detection of human cytomegalovirus (HCMV), nucleic acid sequence-based amplification (NASBA) for detection of early (immediate-early antigen) and late (pp67) mRNA, PCR for detection of HCMV DNA (DNA PCR), culture, and pp65 antigenemia assay, and culture and DNA PCR of urine and throat swab specimens were compared for their abilities to predict the development of disease caused by HCMV (HCMV disease). Of 101 human immunodeficiency virus (HIV)-infected patients with ≤100 CD4+ lymphocytes per mm3, 25 patients developed HCMV disease. The pp65 antigenemia assay (sensitivity, 50%; specificity, 89%) and DNA PCR of blood (sensitivity, 69%; specificity, 75%) were most accurate in predicting the development of HCMV disease within the next 12 months. Both blood culture and late pp67 mRNA NASBA had high specificities (91 and 90%, respectively) but low sensitivities (25 and 13%, respectively). The sensitivities of urine culture, DNA PCR, throat swab specimen culture, DNA PCR, and NASBA of blood for detection of the immediate-early antigen were 73, 87, 53, 67, and 63%, respectively, and the specificities were 58, 46, 76, 60, and 72%, respectively. The positive predictive values of all tests however, were low and did not exceed 50%. In conclusion, virological screening by these qualitative assays for detection of HCMV is of limited value for prediction of the development of HCMV disease in HIV-infected patients. PMID:10655346

  7. Identification and quantification of the main isoflavones and other phytochemicals in soy based nutraceutical products by liquid chromatography-orbitrap high resolution mass spectrometry.

    PubMed

    López-Gutiérrez, Noelia; Romero-González, Roberto; Garrido Frenich, Antonia; Martínez Vidal, José Luis

    2014-06-27

    The specific phytochemicals composition of soy nutritional supplements is usually not labelled. Hence, 12 dietary supplements were analyzed in order to detect and identify the main phytochemicals present in these samples, using a database containing 60 compounds. Ultra-high performance liquid chromatography coupled to single-stage Orbitrap high resolution mass spectrometry (UHPLC-Orbitrap-MS) has been used. Two consecutive extractions, using as extraction solvent a mixture of methanol:water (80:20, v/v), were employed, followed by two dilutions (10 or 100 times depending on the concentration of the components in the sample) with a mixture of an aqueous solution of ammonium acetate 30mM:methanol (50:50, v/v). The method was validated, obtaining adequate recovery and precision values. Limits of detection (LODs) and quantification (LOQs) were calculated, ranging from 2 to 150μgL(-1). Isoflavones were the predominant components present in the analyzed supplements with values higher than 93% of the total amount of phytochemicals in all cases. The aglycones (genistein, daidzein, glycitein and biochanin A) as well as their three conjugated forms, β-glucosides (genistin, daizin and glycitin) were detected and quantified, being daidzein the isoflavone detected at higher concentration in 8 out of 12 samples reported, with values ranging from 684 to 35,970mgkg(-1), whereas biochanin A was detected at very low concentrations, ranging from 18 to 50mgkg(-1). Moreover, other phytochemicals as flavones, flavonols, flavanones and phenolic acids were also detected and quantified. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. The Serum Anion Gap in the Evaluation of Acid-Base Disorders: What Are Its Limitations and Can Its Effectiveness Be Improved?

    PubMed Central

    Nagami, Glenn T.

    2013-01-01

    Summary The serum anion gap has been utilized to identify errors in the measurement of electrolytes, to detect paraproteins, and, most relevant to the nephrologist, to evaluate patients with suspected acid-base disorders. In regard to the latter purpose, traditionally an increased anion gap is identified when it exceeds the upper limit of normal for a particular clinical laboratory measurement. However, because there is a wide range of normal values (often 8–10 mEq/L), an increase in anion concentration can be present in the absence of an increased anion gap. In addition, the type of retained anion can affect the magnitude of the increase in anion gap relative to change in serum [HCO3−] being greater with lactic acidosis compared with ketoacidosis. This review examines the methods of calculation of the serum anion gap in textbooks and published literature, the effect of perturbations other than changes in acid-base balance, and its effectiveness in identifying mild and more severe disturbances in acid-base balance. Limitations of the present methods of determining the normal anion gap and change in the anion gap are highlighted. The possibility of identifying the baseline value for individuals to optimize the use of the calculation in the detection of metabolic acidosis is suggested. PMID:23833313

  9. A comparative analysis of chaotic particle swarm optimizations for detecting single nucleotide polymorphism barcodes.

    PubMed

    Chuang, Li-Yeh; Moi, Sin-Hua; Lin, Yu-Da; Yang, Cheng-Hong

    2016-10-01

    Evolutionary algorithms could overcome the computational limitations for the statistical evaluation of large datasets for high-order single nucleotide polymorphism (SNP) barcodes. Previous studies have proposed several chaotic particle swarm optimization (CPSO) methods to detect SNP barcodes for disease analysis (e.g., for breast cancer and chronic diseases). This work evaluated additional chaotic maps combined with the particle swarm optimization (PSO) method to detect SNP barcodes using a high-dimensional dataset. Nine chaotic maps were used to improve PSO method results and compared the searching ability amongst all CPSO methods. The XOR and ZZ disease models were used to compare all chaotic maps combined with PSO method. Efficacy evaluations of CPSO methods were based on statistical values from the chi-square test (χ 2 ). The results showed that chaotic maps could improve the searching ability of PSO method when population are trapped in the local optimum. The minor allele frequency (MAF) indicated that, amongst all CPSO methods, the numbers of SNPs, sample size, and the highest χ 2 value in all datasets were found in the Sinai chaotic map combined with PSO method. We used the simple linear regression results of the gbest values in all generations to compare the all methods. Sinai chaotic map combined with PSO method provided the highest β values (β≥0.32 in XOR disease model and β≥0.04 in ZZ disease model) and the significant p-value (p-value<0.001 in both the XOR and ZZ disease models). The Sinai chaotic map was found to effectively enhance the fitness values (χ 2 ) of PSO method, indicating that the Sinai chaotic map combined with PSO method is more effective at detecting potential SNP barcodes in both the XOR and ZZ disease models. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Plasmonic gold mushroom arrays with refractive index sensing figures of merit approaching the theoretical limit

    NASA Astrophysics Data System (ADS)

    Shen, Yang; Zhou, Jianhua; Liu, Tianran; Tao, Yuting; Jiang, Ruibin; Liu, Mingxuan; Xiao, Guohui; Zhu, Jinhao; Zhou, Zhang-Kai; Wang, Xuehua; Jin, Chongjun; Wang, Jianfang

    2013-08-01

    Localized surface plasmon resonance (LSPR)-based sensing has found wide applications in medical diagnosis, food safety regulation and environmental monitoring. Compared with commercial propagating surface plasmon resonance (PSPR)-based sensors, LSPR ones are simple, cost-effective and suitable for measuring local refractive index changes. However, the figure of merit (FOM) values of LSPR sensors are generally 1-2 orders of magnitude smaller than those of PSPR ones, preventing the widespread use of LSPR sensors. Here we describe an array of submicrometer gold mushrooms with a FOM reaching ~108, which is comparable to the theoretically predicted upper limit for standard PSPR sensors. Such a high FOM arises from the interference between Wood’s anomaly and the LSPRs. We further demonstrate the array as a biosensor for detecting cytochrome c and alpha-fetoprotein, with their detection limits down to 200 pM and 15 ng ml-1, respectively, suggesting that the array is a promising candidate for label-free biomedical sensing.

  11. Entanglement of 3000 atoms by detecting one photon

    NASA Astrophysics Data System (ADS)

    Vuletic, Vladan

    2016-05-01

    Quantum-mechanically correlated (entangled) states of many particles are of interest in quantum information, quantum computing and quantum metrology. In particular, entangled states of many particles can be used to overcome limits on measurements performed with ensembles of independent atoms (standard quantum limit). Metrologically useful entangled states of large atomic ensembles (spin squeezed states) have been experimentally realized. These states display Gaussian spin distribution functions with a non-negative Wigner quasiprobability distribution function. We report the generation of entanglement in a large atomic ensemble via an interaction with a very weak laser pulse; remarkably, the detection of a single photon prepares several thousand atoms in an entangled state. We reconstruct a negative-valued Wigner function, and verify an entanglement depth (the minimum number of mutually entangled atoms) that comprises 90% of the atomic ensemble containing 3100 atoms. Further technical improvement should allow the generation of more complex Schrödinger cat states, and of states the overcome the standard quantum limit.

  12. Non-linear mixing effects on mass-47 CO2 clumped isotope thermometry: Patterns and implications.

    PubMed

    Defliese, William F; Lohmann, Kyger C

    2015-05-15

    Mass-47 CO(2) clumped isotope thermometry requires relatively large (~20 mg) samples of carbonate minerals due to detection limits and shot noise in gas source isotope ratio mass spectrometry (IRMS). However, it is unreasonable to assume that natural geologic materials are homogenous on the scale required for sampling. We show that sample heterogeneities can cause offsets from equilibrium Δ(47) values that are controlled solely by end member mixing and are independent of equilibrium temperatures. A numerical model was built to simulate and quantify the effects of end member mixing on Δ(47). The model was run in multiple possible configurations to produce a dataset of mixing effects. We verified that the model accurately simulated real phenomena by comparing two artificial laboratory mixtures measured using IRMS to model output. Mixing effects were found to be dependent on end member isotopic composition in δ(13)C and δ(18)O values, and independent of end member Δ(47) values. Both positive and negative offsets from equilibrium Δ(47) can occur, and the sign is dependent on the interaction between end member isotopic compositions. The overall magnitude of mixing offsets is controlled by the amount of variability within a sample; the larger the disparity between end member compositions, the larger the mixing offset. Samples varying by less than 2 ‰ in both δ(13)C and δ(18)O values have mixing offsets below current IRMS detection limits. We recommend the use of isotopic subsampling for δ(13)C and δ(18)O values to determine sample heterogeneity, and to evaluate any potential mixing effects in samples suspected of being heterogonous. Copyright © 2015 John Wiley & Sons, Ltd.

  13. Determination of opiates and cocaine in urine by high pH mobile phase reversed phase UPLC-MS/MS.

    PubMed

    Berg, Thomas; Lundanes, Elsa; Christophersen, Asbjørg S; Strand, Dag Helge

    2009-02-01

    A fast and selective ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method for the determination of opiates (morphine, codeine, 6-monoacetylmorphine (6-MAM), pholcodine, oxycodone, ethylmorphine), cocaine and benzoylecgonine in urine has been developed and validated. Sample preparation was performed by solid phase extraction (SPE) on a mixed mode cation exchange (MCX) cartridge. For optimized chromatographic performance with repeatable retention times, narrow and symmetrical peaks, and focusing of all analytes at the column inlet at gradient start, a basic mobile phase consisting of 5mM ammonium bicarbonate, pH 10.2, and methanol (MeOH) was chosen. Positive electrospray ionization (ESI(+)) MS/MS detection was performed with a minimum of two multiple reaction monitoring (MRM) transitions for each analyte. Deuterium labelled-internal standards were used for six of the analytes. Between-assay retention time repeatabilities (n=10 series, 225 injections in total) had relative standard deviation (RSD) values within 0.1-0.6%. Limit of detection (LOD) and limit of quantification (LOQ) values were in the range 0.003-0.05 microM (0.001-0.02 microg/mL) and 0.01-0.16 microM (0.003-0.06 microg/mL), respectively. The RSD values of the between-assay repeatabilities of concentrations were

  14. Mass amplifying probe for sensitive fluorescence anisotropy detection of small molecules in complex biological samples.

    PubMed

    Cui, Liang; Zou, Yuan; Lin, Ninghang; Zhu, Zhi; Jenkins, Gareth; Yang, Chaoyong James

    2012-07-03

    Fluorescence anisotropy (FA) is a reliable and excellent choice for fluorescence sensing. One of the key factors influencing the FA value for any molecule is the molar mass of the molecule being measured. As a result, the FA method with functional nucleic acid aptamers has been limited to macromolecules such as proteins and is generally not applicable for the analysis of small molecules because their molecular masses are relatively too small to produce observable FA value changes. We report here a molecular mass amplifying strategy to construct anisotropy aptamer probes for small molecules. The probe is designed in such a way that only when a target molecule binds to the probe does it activate its binding ability to an anisotropy amplifier (a high molecular mass molecule such as protein), thus significantly increasing the molecular mass and FA value of the probe/target complex. Specifically, a mass amplifying probe (MAP) consists of a targeting aptamer domain against a target molecule and molecular mass amplifying aptamer domain for the amplifier protein. The probe is initially rendered inactive by a small blocking strand partially complementary to both target aptamer and amplifier protein aptamer so that the mass amplifying aptamer domain would not bind to the amplifier protein unless the probe has been activated by the target. In this way, we prepared two probes that constitute a target (ATP and cocaine respectively) aptamer, a thrombin (as the mass amplifier) aptamer, and a fluorophore. Both probes worked well against their corresponding small molecule targets, and the detection limits for ATP and cocaine were 0.5 μM and 0.8 μM, respectively. More importantly, because FA is less affected by environmental interferences, ATP in cell media and cocaine in urine were directly detected without any tedious sample pretreatment. Our results established that our molecular mass amplifying strategy can be used to design aptamer probes for rapid, sensitive, and selective detection of small molecules by means of FA in complex biological samples.

  15. Habitat models to predict wetland bird occupancy influenced by scale, anthropogenic disturbance, and imperfect detection

    USGS Publications Warehouse

    Glisson, Wesley J.; Conway, Courtney J.; Nadeau, Christopher P.; Borgmann, Kathi L.

    2017-01-01

    Understanding species–habitat relationships for endangered species is critical for their conservation. However, many studies have limited value for conservation because they fail to account for habitat associations at multiple spatial scales, anthropogenic variables, and imperfect detection. We addressed these three limitations by developing models for an endangered wetland bird, Yuma Ridgway's rail (Rallus obsoletus yumanensis), that examined how the spatial scale of environmental variables, inclusion of anthropogenic disturbance variables, and accounting for imperfect detection in validation data influenced model performance. These models identified associations between environmental variables and occupancy. We used bird survey and spatial environmental data at 2473 locations throughout the species' U.S. range to create and validate occupancy models and produce predictive maps of occupancy. We compared habitat-based models at three spatial scales (100, 224, and 500 m radii buffers) with and without anthropogenic disturbance variables using validation data adjusted for imperfect detection and an unadjusted validation dataset that ignored imperfect detection. The inclusion of anthropogenic disturbance variables improved the performance of habitat models at all three spatial scales, and the 224-m-scale model performed best. All models exhibited greater predictive ability when imperfect detection was incorporated into validation data. Yuma Ridgway's rail occupancy was negatively associated with ephemeral and slow-moving riverine features and high-intensity anthropogenic development, and positively associated with emergent vegetation, agriculture, and low-intensity development. Our modeling approach accounts for common limitations in modeling species–habitat relationships and creating predictive maps of occupancy probability and, therefore, provides a useful framework for other species.

  16. Near-infrared incoherent broadband cavity enhanced absorption spectroscopy (NIR-IBBCEAS) for detection and quantification of natural gas components.

    PubMed

    Prakash, Neeraj; Ramachandran, Arun; Varma, Ravi; Chen, Jun; Mazzoleni, Claudio; Du, Ke

    2018-06-28

    The principle of near-infrared incoherent broadband cavity enhanced absorption spectroscopy was employed to develop a novel instrument for detecting natural gas leaks as well as for testing the quality of natural gas mixtures. The instrument utilizes the absorption features of methane, butane, ethane, and propane in the wavelength region of 1100 nm to 1250 nm. The absorption cross-section spectrum in this region for methane was adopted from the HITRAN database, and those for the other three gases were measured in the laboratory. A singular-value decomposition (SVD) based analysis scheme was employed for quantifying methane, butane, ethane, and propane by performing a linear least-square fit. The developed instrument achieved a detection limit of 460 ppm, 141 ppm, 175 ppm and 173 ppm for methane, butane, ethane, and propane, respectively, with a measurement time of 1 second and a cavity length of 0.59 m. These detection limits are less than 1% of the Lower Explosive Limit (LEL) for each gas. The sensitivity can be further enhanced by changing the experimental parameters (such as cavity length, lamp power etc.) and using longer averaging intervals. The detection system is a low-cost and portable instrument suitable for performing field monitorings. The results obtained on the gas mixture emphasize the instrument's potential for deployment at industrial facilities dealing with natural gas, where potential leaks pose a threat to public safety.

  17. One-pot synthesis of a multi-template molecularly imprinted polymer for the extraction of six sulfonamide residues from milk before high-performance liquid chromatography with diode array detection.

    PubMed

    Kechagia, Maria; Samanidou, Victoria; Kabir, Abuzar; Furton, Kenneth G

    2018-02-01

    A highly selective molecularly imprinted polymer sorbent was synthesized and employed for the simultaneous determination of six sulfonamide antibiotic residues (sulfanilamide, sulfacetamide, sulfadiazine, sulfathiazole, sulfamerazine, and sulfamethizole) in milk samples. Multi-analyte imprinted particles were used as a sorbent in solid-phase extraction. Sulfonamides were separated on a high-performance liquid chromatography column (Merck-Lichrospher RP18e, 5 μm 250 × 4 mm) and further identified and quantified by diode array detection. Several parameters including required loading of the molecularly imprinted polymer sorbent, mass of milk, volume, and type of elution solvent, as well as time for absorption and elution were investigated to obtain optimal experimental conditions. For comparison purpose, a non-imprinted polymer was applied under the optimum conditions. The validation study according to the European Union Decision 2002/657/EC was based on the investigation of linearity, selectivity, stability, limits of detection and quantitation, decision limit, detection capability, trueness, precision, and ruggedness according to Youden's approach. The decision limit and detection capability values in the milk were achieved from 101.9 to 113.5 μg/kg and from 114.4 to 135.4 μg/kg, respectively, depending on the target sulfonamide drug. Finally, the optimized protocol was successfully applied to commercial milk samples and human breast milk. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Detecting depression stigma on social media: A linguistic analysis.

    PubMed

    Li, Ang; Jiao, Dongdong; Zhu, Tingshao

    2018-05-01

    Efficient detection of depression stigma in mass media is important for designing effective stigma reduction strategies. Using linguistic analysis methods, this paper aims to build computational models for detecting stigma expressions in Chinese social media posts (Sina Weibo). A total of 15,879 Weibo posts with keywords were collected and analyzed. First, a content analysis was conducted on all 15,879 posts to determine whether each of them reflected depression stigma or not. Second, using four algorithms (Simple Logistic Regression, Multilayer Perceptron Neural Networks, Support Vector Machine, and Random Forest), two groups of classification models were built based on selected linguistic features; one for differentiating between posts with and without depression stigma, and one for differentiating among posts with three specific types of depression stigma. First, 967 of 15,879 posts (6.09%) indicated depression stigma. 39.30%, 15.82%, and 14.99% of them endorsed the stigmatizing view that "People with depression are unpredictable", "Depression is a sign of personal weakness", and "Depression is not a real medical illness", respectively. Second, the highest F-Measure value for differentiating between stigma and non-stigma reached 75.2%. The highest F-Measure value for differentiating among three specific types of stigma reached 86.2%. Due to the limited and imbalanced dataset of Chinese Weibo posts, the findings of this study might have limited generalizability. This paper confirms that incorporating linguistic analysis methods into online detection of stigma can be beneficial to improve the performance of stigma reduction programs. Copyright © 2018 Elsevier B.V. All rights reserved.

  19. A longitudinal evaluation of performance of automated BCR-ABL1 quantitation using cartridge-based detection system.

    PubMed

    Enjeti, Anoop; Granter, Neil; Ashraf, Asma; Fletcher, Linda; Branford, Susan; Rowlings, Philip; Dooley, Susan

    2015-10-01

    An automated cartridge-based detection system (GeneXpert; Cepheid) is being widely adopted in low throughput laboratories for monitoring BCR-ABL1 transcript in chronic myelogenous leukaemia. This Australian study evaluated the longitudinal performance specific characteristics of the automated system.The automated cartridge-based system was compared prospectively with the manual qRT-PCR-based reference method at SA Pathology, Adelaide, over a period of 2.5 years. A conversion factor determination was followed by four re-validations. Peripheral blood samples (n = 129) with international scale (IS) values within detectable range were selected for assessment. The mean bias, proportion of results within specified fold difference (2-, 3- and 5-fold), the concordance rate of major molecular remission (MMR) and concordance across a range of IS values on paired samples were evaluated.The initial conversion factor for the automated system was determined as 0.43. Except for the second re-validation, where a negative bias of 1.9-fold was detected, all other biases fell within desirable limits. A cartridge-specific conversion factor and efficiency value was introduced and the conversion factor was confirmed to be stable in subsequent re-validation cycles. Concordance with the reference method/laboratory at >0.1-≤10 IS was 78.2% and at ≤0.001 was 80%, compared to 86.8% in the >0.01-≤0.1 IS range. The overall and MMR concordance were 85.7% and 94% respectively, for samples that fell within ± 5-fold of the reference laboratory value over the entire period of study.Conversion factor and performance specific characteristics for the automated system were longitudinally stable in the clinically relevant range, following introduction by the manufacturer of lot specific efficiency values.

  20. Simultaneous determination of seven multiclass veterinary antibiotics in surface water samples in the Republic of Korea using liquid chromatography with tandem mass spectrometry.

    PubMed

    Chung, Hyung Suk; Choi, Jeong-Heui; Abd El-Aty, A M; Lee, Young-Jun; Lee, Han Sol; Kim, Sangdon; Jung, Hee-Jung; Kang, Tae-Woo; Shin, Ho-Chul; Shim, Jae-Han

    2016-12-01

    A simultaneous determination method using solid-phase extraction and liquid chromatography with tandem mass spectrometry was developed to detect and quantify the presence of seven multiclass veterinary antibiotics (13 compounds in total) in surface water samples, which included the effluents of livestock wastewater and sewage treatment plants, as well as the reservoir drainage areas from dense animal farms. The pH of all water samples was adjusted to 2 or 6 before solid-phase extraction using Oasis HLB cartridges. The developed method was fully validated in terms of linearity, method detection limit, method quantitation limit, accuracy, and precision. The linearity of all tested drugs was good, with R 2 determination coefficients ≥ 0.9931. The method detection limits and method quantitation limits were 0.1-74.3 and 0.5-236.6 ng/L, respectively. Accuracy and precision values were 71-120 and 1-17%, respectively. The determination method was successfully applied for monitoring water samples obtained from the Yeongsan River in 2015. The most frequently detected antibiotics were lincomycin (96%), sulfamethazine (90%), sulfamethoxazole (88%), and sulfathiazole (50%); the maximum concentrations of which were 398.9, 1151.3, 533.1, and 307.4 ng/L, respectively. Overall, the greatest numbers and concentrations of detected antibiotics were found in samples from the effluents of livestock wastewater, sewage treatment plants, and reservoir drainage areas. Diverse veterinary antibiotics were present, and their presence was dependent upon the commercial sales and environmental properties of the analytes, the geographical positions of the sampling points, and the origin of the water. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Quantification of susceptibility change at high-concentrated SPIO-labeled target by characteristic phase gradient recognition.

    PubMed

    Zhu, Haitao; Nie, Binbin; Liu, Hua; Guo, Hua; Demachi, Kazuyuki; Sekino, Masaki; Shan, Baoci

    2016-05-01

    Phase map cross-correlation detection and quantification may produce highlighted signal at superparamagnetic iron oxide nanoparticles, and distinguish them from other hypointensities. The method may quantify susceptibility change by performing least squares analysis between a theoretically generated magnetic field template and an experimentally scanned phase image. Because characteristic phase recognition requires the removal of phase wrap and phase background, additional steps of phase unwrapping and filtering may increase the chance of computing error and enlarge the inconsistence among algorithms. To solve problem, phase gradient cross-correlation and quantification method is developed by recognizing characteristic phase gradient pattern instead of phase image because phase gradient operation inherently includes unwrapping and filtering functions. However, few studies have mentioned the detectable limit of currently used phase gradient calculation algorithms. The limit may lead to an underestimation of large magnetic susceptibility change caused by high-concentrated iron accumulation. In this study, mathematical derivation points out the value of maximum detectable phase gradient calculated by differential chain algorithm in both spatial and Fourier domain. To break through the limit, a modified quantification method is proposed by using unwrapped forward differentiation for phase gradient generation. The method enlarges the detectable range of phase gradient measurement and avoids the underestimation of magnetic susceptibility. Simulation and phantom experiments were used to quantitatively compare different methods. In vivo application performs MRI scanning on nude mice implanted by iron-labeled human cancer cells. Results validate the limit of detectable phase gradient and the consequent susceptibility underestimation. Results also demonstrate the advantage of unwrapped forward differentiation compared with differential chain algorithms for susceptibility quantification at high-concentrated iron accumulation. Copyright © 2015 Elsevier Inc. All rights reserved.

  2. Gas chromatographic-mass spectrometry method for the detection of busulphan and its metabolites in plasma and urine.

    PubMed

    El-Serafi, Ibrahim; Terelius, Ylva; Twelkmeyer, Brigitte; Hagbjörk, Ann-Louise; Hassan, Zuzana; Hassan, Moustapha

    2013-01-15

    Busulphan is an alkylating agent used as conditioning regimen prior to stem cell transplantation. Busulphan is metabolized in the liver and four major metabolites have been identified. The first metabolite is tetrahydrothiophene which is oxidized to tetrahydrothiophene 1-oxide, then sulfolane and finally 3-hydroxy sulfolane. Despite the low molecular weight and wide polarity range of busulphan and its four metabolites, the use of a fused silica non-polar column significantly enhanced the automated gas chromatography-mass spectrometry of their detection in one simple method. The limit of quantification was 0.5μM for busulphan and all its metabolites except 3-OH sulfolane, which was 1.25μM. This method was validated for all the compounds in both human plasma and urine. Lower limits of quantifications (LLOQs) were run in pentaplicate per compound and all results were within 20% of the nominal values. The recovery was determined by comparing the peak area of two quality control (QC) samples, before and after extraction in plasma and urine, in triplicate. Acceptable precision and accuracy have been obtained; at least 3 standard curves have been run for each compound using three different QCs covering the calibration curve in triplicate. The QC values were within 15% (SD) of the nominal values. Selectivity and sensitivity of all compounds have been measured. Compounds were stable up to 50 days after extraction in -20°C and 48h at RT. Moreover, the compounds were stable for three cycles of freezing and thawing. The method was applied in a clinical case where the patient received high dose busulphan; all the compounds have been detected, identified and quantified both in plasma and urine. Copyright © 2012 Elsevier B.V. All rights reserved.

  3. LAMP kit for diagnosis of non-falciparum malaria in Plasmodium ovale infected patients.

    PubMed

    Cuadros, Juan; Martin Ramírez, Alexandra; González, Iveth J; Ding, Xavier C; Perez Tanoira, Ramon; Rojo-Marcos, Gerardo; Gómez-Herruz, Peña; Rubio, Jose Miguel

    2017-01-07

    Microscopy and rapid diagnosis tests have a limited sensitivity in diagnosis of malaria by Plasmodium ovale. The LAMP kit (LoopAMP®) can be used in the field without special equipment and could have an important role in malaria control programmes in endemic areas and for malaria diagnosis in returned travellers. The performance of the Pan primer of the kit in detecting malaria by P. ovale was compared with the results of standard nPCR in samples of patients returning from P. ovale endemic areas. Plasmodium ovale positive samples (29, tested by PCR and/or microscopy) and malaria negative specimens (398, tested by microscopy and PCR) were collected in different hospitals of Europe from June 2014 to March 2016 and frozen at -20 °C. Boil and spin method was used to extract DNA from all samples and amplification was performed with LoopAMP® MALARIA kit (Eiken Chemical, Japan) in an automated turbidimeter (Eiken 500). The results of LAMP read by turbidimetry and with the naked eye were compared. The kit showed a sensitivity of 100% and a specificity of 97.24% with positive and negative predictive values of 72.5 and 100%, respectively. Naked eyed readings were in accordance with turbidimetry readings (sensitivity, 92.5%, specificity, 98.96% and positive and negative predictive values, respectively, 90.24 and 99.22%). The limit of detection of LAMP assay for P. ovale was between 0.8 and 2 parasites/µl. The Pan primer of the Malaria kit LoopAMP® can detect P. ovale at very low-levels and showed a predictive negative value of 100%. This tool can be useful in malaria control and elimination programmes and in returned travellers from P. ovale endemic areas. Naked eye readings are equivalent to automated turbidimeter readings in specimens obtained with EDTA.

  4. Mass-tag enhanced immuno-laser desorption/ionization mass spectrometry for sensitive detection of intact protein antigens.

    PubMed

    Lorey, Martina; Adler, Belinda; Yan, Hong; Soliymani, Rabah; Ekström, Simon; Yli-Kauhaluoma, Jari; Laurell, Thomas; Baumann, Marc

    2015-05-19

    A new read-out method for antibody arrays using laser desorption/ionization-mass spectrometry (LDI-MS) is presented. Small, photocleavable reporter molecules with a defined mass called "mass-tags" are used for detection of immunocaptured proteins from human plasma. Using prostate specific antigen (PSA), a biomarker for prostate cancer, as a model antigen, a high sensitivity generic detection methodology based immunocapture with a primary antibody and with a biotin labeled secondary antibody coupled to mass-tagged avidin is demonstrated. As each secondary antibody can bind several avidin molecules, each having a large number of mass-tags, signal amplification can be achieved. The developed PSA sandwich mass-tag analysis method provided a limit of detection below 200 pg/mL (6 pM) for a 10 μL plasma sample, well below the clinically relevant cutoff value of 3-4 ng/mL. This brings the limit of detection (LOD) for detection of intact antigens with matrix-assisted laser desorption/ionization-mass spectrometry (MALDI-MS) down to levels comparable to capture by anti-peptide antibodies selected reaction monitoring (SISCAPA SRM) and enzyme linked immunosorbent assay (ELISA), as 6 pM corresponds to a maximal amount of 60 amol PSA captured on-spot. We propose the potential use of LDI (laser desorption/ionization) with mass-tag read-out implemented in a sandwich assay format for low abundant and/or early disease biomarker detection.

  5. Simultaneous determination of ethyl carbamate and urea in Korean rice wine by ultra-performance liquid chromatography coupled with mass spectrometric detection.

    PubMed

    Lee, Gyeong-Hweon; Bang, Dae-Young; Lim, Jung-Hoon; Yoon, Seok-Min; Yea, Myeong-Jai; Chi, Young-Min

    2017-10-15

    In this study, a rapid method for simultaneous detection of ethyl carbamate (EC) and urea in Korean rice wine was developed. To achieve quantitative analysis of EC and urea, the conditions for Ultra-performance liquid chromatography (UPLC) separation and atmospheric-pressure chemical ionization tandem mass spectrometry (APCI-MS/MS) detection were first optimized. Under the established conditions, the detection limit, relative standard deviation and linear range were 2.83μg/L, 3.75-5.96%, and 0.01-10.0mg/L, respectively, for urea; the corresponding values were 0.17μg/L, 1.06-4.01%, and 1.0-50.0μg/L, respectively, for EC. The correlation between the contents of EC and its precursor urea was determined under specific pH (3.5 and 4.5) and temperature (4, 25, and 50°C) conditions using the developed method. As a result, EC content was increased with greater temperature and lower pH. In Korean rice wine, urea was detected 0.19-1.37mg/L and EC was detected 2.0-7.7μg/L. The method developed in this study, which has the advantages of simplified sample preparation, low detection limits, and good selectivity, was successfully applied for the rapid analysis of EC and urea. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Ultrasensitive Detection of Ebola Virus Oligonucleotide Based on Upconversion Nanoprobe/Nanoporous Membrane System.

    PubMed

    Tsang, Ming-Kiu; Ye, WeiWei; Wang, Guojing; Li, Jingming; Yang, Mo; Hao, Jianhua

    2016-01-26

    Ebola outbreaks are currently of great concern, and therefore, development of effective diagnosis methods is urgently needed. The key for lethal virus detection is high sensitivity, since early-stage detection of virus may increase the probability of survival. Here, we propose a luminescence scheme of assay consisting of BaGdF5:Yb/Er upconversion nanoparticles (UCNPs) conjugated with oligonucleotide probe and gold nanoparticles (AuNPs) linked with target Ebola virus oligonucleotide. As a proof of concept, a homogeneous assay was fabricated and tested, yielding a detection limit at picomolar level. The luminescence resonance energy transfer is ascribed to the spectral overlapping of upconversion luminescence and the absorption characteristics of AuNPs. Moreover, we anchored the UCNPs and AuNPs on a nanoporous alumina (NAAO) membrane to form a heterogeneous assay. Importantly, the detection limit was greatly improved, exhibiting a remarkable value at the femtomolar level. The enhancement is attributed to the increased light-matter interaction throughout the nanopore walls of the NAAO membrane. The specificity test suggested that the nanoprobes were specific to Ebola virus oligonucleotides. The strategy combining UCNPs, AuNPs, and NAAO membrane provides new insight into low-cost, rapid, and ultrasensitive detection of different diseases. Furthermore, we explored the feasibility of clinical application by using inactivated Ebola virus samples. The detection results showed great potential of our heterogeneous design for practical application.

  7. Analysis of acrylamide in food products by in-line preconcentration capillary zone electrophoresis.

    PubMed

    Bermudo, Elisabet; Núñez, Oscar; Puignou, Luis; Galceran, Maria Teresa

    2006-09-29

    Two in-line preconcentration capillary zone electrophoresis (CZE) methods (field amplified sample injection (FASI) and stacking with sample matrix removal (LVSS)) have been evaluated for the analysis of acrylamide (AA) in foodstuffs. To allow the determination of AA by CZE, it was derivatized using 2-mercaptobenzoic acid. For FASI, the optimum conditions were water at pH > or = 10 adjusted with NH3 as sample solvent, 35 s hydrodynamic injection (0.5 psi) of a water plug, 35 s of electrokinetic injection (-10 kV) of the sample, and 6s hydrodynamic injection (0.5 psi) of another water plug to prevent AA removal by EOF. In stacking with sample matrix removal, the reversal time was found to be around 3.3 min. A 40 mM phosphate buffer (pH 8.5) was used as carrier electrolyte for CZE separation in both cases. For both FASI and LVSS methods, linear calibration curves over the range studied (10-1000 microg L(-1) and 25-1000 microg L(-1), respectively), limit of detection (LOD) on standards (1 microg L(-1) for FASI and 7 microg L(-1) for LVSS), limit of detection on samples (3 ng g(-1) for FASI and 20 ng g(-1) for LVSS) and both run-to-run (up to 14% for concentration and 0.8% for time values) and day-to-day precisions (up to 16% and 5% for concentration and time values, respectively) were established. Due to the lower detection limits obtained with the FASI-CZE this method was applied to the analysis of AA in different foodstuffs such as biscuits, cereals, crisp bread, snacks and coffee, and the results were compared with those obtained by LC-MS/MS.

  8. [Are disinfectant residues remained after cleaning hemodialysis machine procedure safe for patients?].

    PubMed

    Szewczyk, Małgorzata; Grzeszczuk, Karolina; Walski, Tomasz; Suder, Marek; Komorowska, Małgorzata

    2013-01-01

    The dialysis machine shall be cleaned and disinfected after each patient treatment or after every 72 hours break in working. An acceptable disinfectants such as Puristeril plus or Puristeril 340, Citrosteril, Diasteril and Sporotal are used for decontamination. Puristeril 340 is designed for cold disinfection and due to the low pH value, the necessary decalcification of hemodialysis machines is easily achieved. It can be used for all haemodialysis systems like hemodialysis machines, water treatment devices and circuit pipes. Diluted Puristeril decomposes in a non-toxic way. Degradation products of peracetic acid, which is main component of Puristeril are: hydrogen peroxide and acetic acid. Peracetic acid is widely used for disinfection due to its exceptionally broad spectrum of microbiocidal activity at low concentrations and short exposure times. After use Puristeril is easily removable by rinsing with water. This paper deals with the effect of the Puristeril toxicity on blood as a function of its concentration and incubation time. Concentration range of 3.5-70 ppm was used, with particular emphasis on concentrations close to 5 ppm, a value is the limit of sensitivity of strips of starch potassium iodide, the tests for detection of peracetic acid. There was a strong increase in autohaemolysis and malondialdehyde concentrations with increasing concentration of Puristeril. There were also changes in dependence on the parameters of the incubation time, with the greatest effects obtained after 2 hours incubation with Puristeril. The detection limit of peracetic acid used strips of starch potassium iodide does not guarantee the safety of a patient undergoing hemodialysis. Even the residual concentration of Puristeril plus cause increased lipid peroxidation of membrane, and therefore suggest the routine use of stripes on the lower limit of detection of peracetic acid or implement measurement of hydrogen peroxide residues performed with sensitivity 1 ppm.

  9. Identification of SSR and retrotransposon-based molecular markers linked to morphological characters in oily sunfl ower (Helianthus annuus L.) under natural and water-limited states.

    PubMed

    Ali, Soleimani Gezeljeh; Darvishzadeh, Reza; Ebrahimi, Asa; Bihamta, Mohammad Reza

    2018-03-01

    Sunflower is an important source of edible oil. Drought is known as an important factor limiting the growth and productivity of field crops in most parts of the world. Agricultural biotechnology mainly aims at developing crops with higher tolerance to the challenging environmental conditions, such as drought. This study examined a number of morphological characters, along with relative water content (RWC) in 100 inbred sunflower lines. A 10 × 10 simple lattice design with two replications was employed to measure the mentioned parameters under natural and water-limited states during two successive years. In molecular trial, 30 simple sequence repeat (SSR) primer pairs, as well as 14 inter-retrotransposon amplified polymorphism (IRAP) and 14 retrotransposon-microsatellite amplified polymorphism (REMAP) primer combinations were used for DNA fingerprinting of the lines. Most of the examined characters had lower average values under water-limited than natural states. Maximum and minimum reductions were observed in the cases of yield and oil percentage, respectively. The broad-sense heritabilities for all the examined characters were 0.20-0.73 and 0.10-0.34 under natural and water-limited states, respectively. In the studied samples, 8.97% of the 435 possible locus pairs of the SSRs represented significant linkage disequilibrium (LD) levels. In the association analysis using SSR markers, 22 and 21 markers were identified (P ≤ 0.05) for the studied characters under natural and water-limited states, respectively. The corresponding values were 50 and 37 using retrotransposon-based molecular markers. Some detected markers were communal between the characters under water-limited and natural states. This was in line with the phenotypic correlations detected between the characters. Communal markers facilitate the simultaneous selection of several characters and can thus improve the efficacy of selection based on markers in the plant-breeding activities.

  10. Anti-D immunoglobulin preparations: the stability of anti-D concentrations and the error of the assay of anti-D.

    PubMed

    Hughes-Jones, N C; Hunt, V A; Maycock, W D; Wesley, E D; Vallet, L

    1978-01-01

    An analysis of the assay of 28 preparations of anti-D immunoglobulin using a radioisotope method carried out at 6-montly intervals for 2--4.5 years showed an average fall in anti-D concentration of 10.6% each year, with 99% confidence limits of 6.8--14.7%. The fall in anti-D concentration after storage at 37 degrees C for 1 month was less than 8%, the minimum change that could be detected. No significant change in physical characteristics of the immunoglobulin were detected. The error of a single estimate of anti-D by the radioisotope method (125I-labelled anti-IgG) used here was calculated to be such that the true value probably (p = 0.95) lay between 66 and 150% of the estimated value.

  11. Identifying and detecting facial expressions of emotion in peripheral vision.

    PubMed

    Smith, Fraser W; Rossit, Stephanie

    2018-01-01

    Facial expressions of emotion are signals of high biological value. Whilst recognition of facial expressions has been much studied in central vision, the ability to perceive these signals in peripheral vision has only seen limited research to date, despite the potential adaptive advantages of such perception. In the present experiment, we investigate facial expression recognition and detection performance for each of the basic emotions (plus neutral) at up to 30 degrees of eccentricity. We demonstrate, as expected, a decrease in recognition and detection performance with increasing eccentricity, with happiness and surprised being the best recognized expressions in peripheral vision. In detection however, while happiness and surprised are still well detected, fear is also a well detected expression. We show that fear is a better detected than recognized expression. Our results demonstrate that task constraints shape the perception of expression in peripheral vision and provide novel evidence that detection and recognition rely on partially separate underlying mechanisms, with the latter more dependent on the higher spatial frequency content of the face stimulus.

  12. Identifying and detecting facial expressions of emotion in peripheral vision

    PubMed Central

    Rossit, Stephanie

    2018-01-01

    Facial expressions of emotion are signals of high biological value. Whilst recognition of facial expressions has been much studied in central vision, the ability to perceive these signals in peripheral vision has only seen limited research to date, despite the potential adaptive advantages of such perception. In the present experiment, we investigate facial expression recognition and detection performance for each of the basic emotions (plus neutral) at up to 30 degrees of eccentricity. We demonstrate, as expected, a decrease in recognition and detection performance with increasing eccentricity, with happiness and surprised being the best recognized expressions in peripheral vision. In detection however, while happiness and surprised are still well detected, fear is also a well detected expression. We show that fear is a better detected than recognized expression. Our results demonstrate that task constraints shape the perception of expression in peripheral vision and provide novel evidence that detection and recognition rely on partially separate underlying mechanisms, with the latter more dependent on the higher spatial frequency content of the face stimulus. PMID:29847562

  13. Background estimation and player detection in badminton video clips using histogram of pixel values along temporal dimension

    NASA Astrophysics Data System (ADS)

    Peng, Yahui; Ma, Xiao; Gao, Xinyu; Zhou, Fangxu

    2015-12-01

    Computer vision is an important tool for sports video processing. However, its application in badminton match analysis is very limited. In this study, we proposed a straightforward but robust histogram-based background estimation and player detection methods for badminton video clips, and compared the results with the naive averaging method and the mixture of Gaussians methods, respectively. The proposed method yielded better background estimation results than the naive averaging method and more accurate player detection results than the mixture of Gaussians player detection method. The preliminary results indicated that the proposed histogram-based method could estimate the background and extract the players accurately. We conclude that the proposed method can be used for badminton player tracking and further studies are warranted for automated match analysis.

  14. Systematic review on the role of serum tumor markers in the detection of recurrent pancreatic cancer.

    PubMed

    Daamen, Lois A; Groot, Vincent P; Heerkens, Hanne D; Intven, Martijn P W; van Santvoort, Hjalmar C; Molenaar, I Quintus

    2018-04-01

    Biomarker testing can be helpful to monitor disease progression after resection of pancreatic cancer. This systematic review aims to give an overview of the literature on the diagnostic value of serum tumor markers for the detection of recurrent pancreatic cancer during follow-up. A systematic search was performed to 2 October 2017. All studies reporting on the diagnostic value of postoperatively measured serum biomarkers for the detection of pancreatic cancer recurrence were included. Data on diagnostic accuracy of tumor markers were extracted. Forest plots and pooled values of sensitivity and specificity were calculated. Four articles described test results of CA 19-9. A pooled sensitivity and specificity of respectively 0.73 (95% CI 0.66-0.80) and 0.83 (95% CI 0.73-0.91) were calculated. One article reported on CEA, showing a sensitivity of 50% and specificity of 65%. No other serum tumor markers were discussed for surveillance purposes in the current literature. Although testing of serum CA 19-9 has considerable limitations, CA 19-9 remains the most used serum tumor marker for surveillance after surgical resection of pancreatic cancer. Further studies are needed to assess the role of serum tumor marker testing in the detection of recurrent pancreatic cancer and to optimize surveillance strategies. Copyright © 2017 International Hepato-Pancreato-Biliary Association Inc. Published by Elsevier Ltd. All rights reserved.

  15. Undoing measurement-induced dephasing in circuit QED

    NASA Astrophysics Data System (ADS)

    Frisk Kockum, A.; Tornberg, L.; Johansson, G.

    2012-05-01

    We analyze the backaction of homodyne detection and photodetection on superconducting qubits in circuit quantum electrodynamics. Although both measurement schemes give rise to backaction in the form of stochastic phase rotations, which leads to dephasing, we show that this can be perfectly undone provided that the measurement signal is fully accounted for. This result improves on an earlier one [Phys. Rev. APLRAAN1050-294710.1103/PhysRevA.82.012329 82, 012329 (2010)], showing that the method suggested can be made to realize a perfect two-qubit parity measurement. We propose a benchmarking experiment on a single qubit to demonstrate the method using homodyne detection. By analyzing the limited measurement efficiency of the detector and bandwidth of the amplifier, we show that the parameter values necessary to see the effect are within the limits of existing technology.

  16. Quantum nondemolition measurements - Comment on recent developments. [detectability of extremely weak signals

    NASA Technical Reports Server (NTRS)

    Von Roos, O.

    1978-01-01

    The limitations of the detectability of extremely weak signals (gravitational radiation for instance) imposed by Heisenberg's uncertainty principle on the sequential determination of those signals have been explored recently. A variety of schemes have been proposed to circumvent these limitations. Although all of the earlier attempts have been proven fruitless a recent proposal seems to be quite promising. The scheme, consisting of two harmonic oscillators interacting with each other in a peculiar way, allows for an exact analytical solution which is derived here. If it can be assumed that the expectation value of one of the canonical variables of the total system suffices to monitor the weak signal it can be shown that, in the absence of thermal noise, arbitrarily weak signals can in principle be measured without interference from the uncertainty principle.

  17. Improved high-performance liquid chromatography (HPLC) method for qualitative and quantitative analysis of allantoin in Zea mays.

    PubMed

    Haghi, Ghasem; Arshi, Rohollah; Safaei, Alireza

    2008-02-27

    A high-performance liquid chromatography (HPLC) method for the qualitative and quantitative analysis of allantoin in silk and seed of Zea mays has been developed. Allantoin separation in crude extract was achieved using a C 18 column and phosphate buffer solution (pH 3.0) as a mobile phase at ambient temperature at a flow rate of 1.0 mL/min and detected at 210 nm. The results showed that the amount of allantoin in samples was between 14 and 271 mg/100 g of dry plant material. A comprehensive validation of the method including sensitivity, linearity, repeatability, and recovery was conducted. The calibration curve was linear over the range of 0.2-200 microg/mL with a correlation coefficient of r2>0.999. Limit of detection (LOD, S/N=3) and limit of quantification (LOQ) values of the allantoin were 0.05 and 0.2 microg/mL (1.0 and 4.0 ng) respectively. The relative standard deviation (RSD) value of the repeatability was reported within 1.2%. The average recovery of allantoin added to samples was 100.6% with RSD of 1.5%.

  18. Recovering incomplete data using Statistical Multiple Imputations (SMI): a case study in environmental chemistry.

    PubMed

    Mercer, Theresa G; Frostick, Lynne E; Walmsley, Anthony D

    2011-10-15

    This paper presents a statistical technique that can be applied to environmental chemistry data where missing values and limit of detection levels prevent the application of statistics. A working example is taken from an environmental leaching study that was set up to determine if there were significant differences in levels of leached arsenic (As), chromium (Cr) and copper (Cu) between lysimeters containing preservative treated wood waste and those containing untreated wood. Fourteen lysimeters were setup and left in natural conditions for 21 weeks. The resultant leachate was analysed by ICP-OES to determine the As, Cr and Cu concentrations. However, due to the variation inherent in each lysimeter combined with the limits of detection offered by ICP-OES, the collected quantitative data was somewhat incomplete. Initial data analysis was hampered by the number of 'missing values' in the data. To recover the dataset, the statistical tool of Statistical Multiple Imputation (SMI) was applied, and the data was re-analysed successfully. It was demonstrated that using SMI did not affect the variance in the data, but facilitated analysis of the complete dataset. Copyright © 2011 Elsevier B.V. All rights reserved.

  19. Determination of Minor and Trace Metals in Aluminum and Aluminum Alloys by ICP-AES; Evaluation of the Uncertainty and Limit of Quantitation from Interlaboratory Testing.

    PubMed

    Uemoto, Michihisa; Makino, Masanori; Ota, Yuji; Sakaguchi, Hiromi; Shimizu, Yukari; Sato, Kazuhiro

    2018-01-01

    Minor and trace metals in aluminum and aluminum alloys have been determined by inductively coupled plasma atomic emission spectrometry (ICP-AES) as an interlaboratory testing toward standardization. The trueness of the measured data was successfully investigated to improve the analytical protocols, using certified reference materials of aluminum. Their precision could also be evaluated, feasible to estimate the uncertainties separately. The accuracy (trueness and precision) of the data were finally in good agreement with the certified values and assigned uncertainties. Repeated measurements of aluminum solutions with different concentrations of the analytes revealed the relative standard deviations of the measurements with concentrations, thus enabling their limits of quantitation. They differed separately and also showed slightly higher values with an aluminum matrix than those without one. In addition, the upper limit of the detectable concentration of silicon with simple acid digestion was estimated to be 0.03 % in the mass fraction.

  20. Minimum Detectable Activity for Tomographic Gamma Scanning System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Venkataraman, Ram; Smith, Susan; Kirkpatrick, J. M.

    2015-01-01

    For any radiation measurement system, it is useful to explore and establish the detection limits and a minimum detectable activity (MDA) for the radionuclides of interest, even if the system is to be used at far higher values. The MDA serves as an important figure of merit, and often a system is optimized and configured so that it can meet the MDA requirements of a measurement campaign. The non-destructive assay (NDA) systems based on gamma ray analysis are no exception and well established conventions, such the Currie method, exist for estimating the detection limits and the MDA. However, the Tomographicmore » Gamma Scanning (TGS) technique poses some challenges for the estimation of detection limits and MDAs. The TGS combines high resolution gamma ray spectrometry (HRGS) with low spatial resolution image reconstruction techniques. In non-imaging gamma ray based NDA techniques measured counts in a full energy peak can be used to estimate the activity of a radionuclide, independently of other counting trials. However, in the case of the TGS each “view” is a full spectral grab (each a counting trial), and each scan consists of 150 spectral grabs in the transmission and emission scans per vertical layer of the item. The set of views in a complete scan are then used to solve for the radionuclide activities on a voxel by voxel basis, over 16 layers of a 10x10 voxel grid. Thus, the raw count data are not independent trials any more, but rather constitute input to a matrix solution for the emission image values at the various locations inside the item volume used in the reconstruction. So, the validity of the methods used to estimate MDA for an imaging technique such as TGS warrant a close scrutiny, because the pair-counting concept of Currie is not directly applicable. One can also raise questions as to whether the TGS, along with other image reconstruction techniques which heavily intertwine data, is a suitable method if one expects to measure samples whose activities are at or just above MDA levels. The paper examines methods used to estimate MDAs for a TGS system, and explores possible solutions that can be rigorously defended.« less

  1. Setting maximum limits for trace elements in baby food in European legislation: the outcome of International Measurement Evaluation Programme®-33.

    PubMed

    Cordeiro, F; Baer, I; Robouch, P; Emteborg, H; Can, S Z; Krata, A; Zampella, M; Quétel, C R; Hearn, R; De la Calle, B

    2013-01-01

    The Institute for Reference Materials and Measurements (IRMM) of the Joint Research Centre (JRC), a Directorate-General of the European Commission, operates the International Measurement Evaluation Programme® (IMEP). It organises various types of inter-laboratory comparisons in support of European Union policies. This paper presents the results of a proficiency testing exercise (PT) focusing on the determination of total cadmium (Cd) and total lead (Pb) mass fractions in baby food in support to Commission Regulation (EC) 1881/2006 of 19 December 2006 setting maximum levels for certain contaminants in foodstuffs. The test material used in this exercise was soya-based baby food formula purchased in a local pharmacy and prepared by the Reference Materials Unit of the IRMM for this exercise. Sixty-six laboratories from 23 countries registered to the exercise and 61 of them reported results. Each participant received one bottle containing approximately 15 g of test material. Participants were asked to quantify the measurands in the powder and in the reconstituted formula. Reference values independent from the participants' results were established using isotope dilution inductively coupled plasma mass spectrometry. The total Cd mass fraction was determined by IRMM and LGC Ltd (UK), while the total Pb was determined by IRMM. The standard deviation for proficiency assessment σ^ was set at 22% of the assigned value for all measurands. Laboratories were rated with z- and ζ- (zeta) scores in accordance with ISO 13528. The outcome of this exercise is clearly influenced by the very low level of Cd and Pb content in the test material which triggered: a high number of 'less than' values; overestimated values especially for Pb very likely due to contamination; and a visible method influence in the case of Pb (methods based on atomic absorption were not sensitive enough to attain such low limits of detection). The results were also evaluated with regard to the reported limit of detection and some incoherencies were observed.

  2. Occurrence of hexavalent chromium in ground water in the western Mojave Desert, California

    USGS Publications Warehouse

    Ball, J.W.; Izbicki, J.A.

    2004-01-01

    About 200 samples from selected public supply, domestic, and observation wells completed in alluvial aquifers underlying the western Mojave Desert were analyzed for total dissolved Cr and Cr(VI). Because Cr(VI) is difficult to preserve, samples were analyzed by 3 methods. Chromium(VI) was determined in the field using both a direct colorimetric method and EPA method 218.6, and samples were speciated in the field for later analysis in the laboratory using a cation-exchange method developed for the study described in this paper. Comparison of the direct colorimetric method and EPA method 218.6 with the new cation-exchange method yielded r2 values of 0.9991 and 0.9992, respectively. Total dissolved Cr concentrations ranged from less than the 0.1 ??g/l detection limit to 60 ??g/l, and almost all the Cr present was Cr(VI). Near recharge areas along the mountain front pH values were near neutral, dissolved O2 concentrations were near saturation, and Cr(VI) concentrations were less than the 0.1 ??g/l detection limit. Chromium(VI) concentrations and pH values increased downgradient as long as dissolved O 2 was present. However, low Cr(VI) concentrations were associated with low dissolved O2 concentrations near ground-water discharge areas along dry lakes. Chromium(VI) concentrations as high as 60 ??g/l occurred in ground water from the Sheep Creek fan alluvial deposits weathered from mafic rock derived from the San Gabriel Mountains, and Cr(VI) concentrations as high as about 36 ??g/l were present in ground water from alluvial deposits weathered from less mafic granitic, metamorphic, and volcanic rocks. Chromium(III) was the predominant form of Cr only in areas where dissolved O2 concentrations were less than 1 mg/l and was detected at a median concentration of 0.1 ??g/l, owing to its low solubility in water of near-neutral pH. Depending on local hydrogeologic conditions and the distribution of dissolved O2, Cr(VI) concentrations may vary considerably with depth. Samples collected under pumping conditions from different depths within wells show that Cr(VI) concentrations can range from less than the 0.1 ??g/l detection limit to 36 ??g/l in a single well and that dissolved O2 concentrations likely control the concentration and redox speciation of Cr in ground water.

  3. Anatomical background noise power spectrum in differential phase contrast breast images

    NASA Astrophysics Data System (ADS)

    Garrett, John; Ge, Yongshuai; Li, Ke; Chen, Guang-Hong

    2015-03-01

    In x-ray breast imaging, the anatomical noise background of the breast has a significant impact on the detection of lesions and other features of interest. This anatomical noise is typically characterized by a parameter, β, which describes a power law dependence of anatomical noise on spatial frequency (the shape of the anatomical noise power spectrum). Large values of β have been shown to reduce human detection performance, and in conventional mammography typical values of β are around 3.2. Recently, x-ray differential phase contrast (DPC) and the associated dark field imaging methods have received considerable attention as possible supplements to absorption imaging for breast cancer diagnosis. However, the impact of these additional contrast mechanisms on lesion detection is not yet well understood. In order to better understand the utility of these new methods, we measured the β indices for absorption, DPC, and dark field images in 15 cadaver breast specimens using a benchtop DPC imaging system. We found that the measured β value for absorption was consistent with the literature for mammographic acquisitions (β = 3.61±0.49), but that both DPC and dark field images had much lower values of β (β = 2.54±0.75 for DPC and β = 1.44±0.49 for dark field). In addition, visual inspection showed greatly reduced anatomical background in both DPC and dark field images. These promising results suggest that DPC and dark field imaging may help provide improved lesion detection in breast imaging, particularly for those patients with dense breasts, in whom anatomical noise is a major limiting factor in identifying malignancies.

  4. ERRATUM: "Reliability of the Detection of the Baryon Acoustic Peak" (2009, ApJ, 696, L93)

    NASA Astrophysics Data System (ADS)

    Martínez, Vicent J.; Arnalte-Mur, Pablo; Saar, Enn; de la Cruz, Pablo; Jesús Pons-Bordería, María; Paredes, Silvestre; Fernández-Soto, Alberto; Tempel, Elmo

    2009-10-01

    Due to an error in applying the passive evolution to transform Mg (z = 0) magnitudes to Mg (z = 0.3), the values of the magnitude limits for the samples DR7-LRG and DR7-LRG-VL quoted in Table 1 were not correct. The corrected Table 1 is appended below. Note that although the redshift limits of the sample DR7-LRG are the same as in Eisenstein et al. (2005), the magnitude limits are therefore slightly shifted (see Table 1). Once this fact is considered, figures and results are completely unaffected. We are very grateful to Eyal Kazin for pointing out the error.

  5. Experiment K305: Quantitative analysis of selected bone parameters. Supplement 3A: Trabecular spacing and orientation in the long bones

    NASA Technical Reports Server (NTRS)

    Judy, M. M.

    1981-01-01

    Values of mean trabecular spacing computed from optical diffraction patterns of 1:1 X-ray micrographs of tibial metaphysis and those obtained by standard image digitization techniques show excellent agreement. Upper limits on values of mean trabecular orientation deduced from diffraction patterns and the images are also in excellent agreement. Values of the ratio of mean trabecular spatial density in a region of 300 micrometers distal to the downwardly directed convexity in the cartilage growth plate to the value adjacent to the plate determined for flight animals sacrificed at recovery were significantly smaller than values for vivarium control animals. No significant differences were found in proximal regions. No significant differences in mean trabecular orientation were detected. Decreased values of trabecular spatial density and of both obsteoblastic activity and trabecular cross-sectional area noted in collateral researches suggest decreased modeling activity under weightlessness.

  6. Metabolomics variable selection and classification in the presence of observations below the detection limit using an extension of ERp.

    PubMed

    van Reenen, Mari; Westerhuis, Johan A; Reinecke, Carolus J; Venter, J Hendrik

    2017-02-02

    ERp is a variable selection and classification method for metabolomics data. ERp uses minimized classification error rates, based on data from a control and experimental group, to test the null hypothesis of no difference between the distributions of variables over the two groups. If the associated p-values are significant they indicate discriminatory variables (i.e. informative metabolites). The p-values are calculated assuming a common continuous strictly increasing cumulative distribution under the null hypothesis. This assumption is violated when zero-valued observations can occur with positive probability, a characteristic of GC-MS metabolomics data, disqualifying ERp in this context. This paper extends ERp to address two sources of zero-valued observations: (i) zeros reflecting the complete absence of a metabolite from a sample (true zeros); and (ii) zeros reflecting a measurement below the detection limit. This is achieved by allowing the null cumulative distribution function to take the form of a mixture between a jump at zero and a continuous strictly increasing function. The extended ERp approach is referred to as XERp. XERp is no longer non-parametric, but its null distributions depend only on one parameter, the true proportion of zeros. Under the null hypothesis this parameter can be estimated by the proportion of zeros in the available data. XERp is shown to perform well with regard to bias and power. To demonstrate the utility of XERp, it is applied to GC-MS data from a metabolomics study on tuberculosis meningitis in infants and children. We find that XERp is able to provide an informative shortlist of discriminatory variables, while attaining satisfactory classification accuracy for new subjects in a leave-one-out cross-validation context. XERp takes into account the distributional structure of data with a probability mass at zero without requiring any knowledge of the detection limit of the metabolomics platform. XERp is able to identify variables that discriminate between two groups by simultaneously extracting information from the difference in the proportion of zeros and shifts in the distributions of the non-zero observations. XERp uses simple rules to classify new subjects and a weight pair to adjust for unequal sample sizes or sensitivity and specificity requirements.

  7. Evaluation of a Broad-Spectrum Partially Automated Adverse Event Surveillance System: A Potential Tool for Patient Safety Improvement in Hospitals With Limited Resources.

    PubMed

    Saikali, Melody; Tanios, Alain; Saab, Antoine

    2017-11-21

    The aim of the study was to evaluate the sensitivity and resource efficiency of a partially automated adverse event (AE) surveillance system for routine patient safety efforts in hospitals with limited resources. Twenty-eight automated triggers from the hospital information system's clinical and administrative databases identified cases that were then filtered by exclusion criteria per trigger and then reviewed by an interdisciplinary team. The system, developed and implemented using in-house resources, was applied for 45 days of surveillance, for all hospital inpatient admissions (N = 1107). Each trigger was evaluated for its positive predictive value (PPV). Furthermore, the sensitivity of the surveillance system (overall and by AE category) was estimated relative to incidence ranges in the literature. The surveillance system identified a total of 123 AEs among 283 reviewed medical records, yielding an overall PPV of 52%. The tool showed variable levels of sensitivity across and within AE categories when compared with the literature, with a relatively low overall sensitivity estimated between 21% and 44%. Adverse events were detected in 23 of the 36 AE categories defined by an established harm classification system. Furthermore, none of the detected AEs were voluntarily reported. The surveillance system showed variable sensitivity levels across a broad range of AE categories with an acceptable PPV, overcoming certain limitations associated with other harm detection methods. The number of cases captured was substantial, and none had been previously detected or voluntarily reported. For hospitals with limited resources, this methodology provides valuable safety information from which interventions for quality improvement can be formulated.

  8. Methods for threshold determination in multiplexed assays

    DOEpatents

    Tammero, Lance F. Bentley; Dzenitis, John M; Hindson, Benjamin J

    2014-06-24

    Methods for determination of threshold values of signatures comprised in an assay are described. Each signature enables detection of a target. The methods determine a probability density function of negative samples and a corresponding false positive rate curve. A false positive criterion is established and a threshold for that signature is determined as a point at which the false positive rate curve intersects the false positive criterion. A method for quantitative analysis and interpretation of assay results together with a method for determination of a desired limit of detection of a signature in an assay are also described.

  9. Automated Detection of Actinic Keratoses in Clinical Photographs

    PubMed Central

    Hames, Samuel C.; Sinnya, Sudipta; Tan, Jean-Marie; Morze, Conrad; Sahebian, Azadeh; Soyer, H. Peter; Prow, Tarl W.

    2015-01-01

    Background Clinical diagnosis of actinic keratosis is known to have intra- and inter-observer variability, and there is currently no non-invasive and objective measure to diagnose these lesions. Objective The aim of this pilot study was to determine if automatically detecting and circumscribing actinic keratoses in clinical photographs is feasible. Methods Photographs of the face and dorsal forearms were acquired in 20 volunteers from two groups: the first with at least on actinic keratosis present on the face and each arm, the second with no actinic keratoses. The photographs were automatically analysed using colour space transforms and morphological features to detect erythema. The automated output was compared with a senior consultant dermatologist’s assessment of the photographs, including the intra-observer variability. Performance was assessed by the correlation between total lesions detected by automated method and dermatologist, and whether the individual lesions detected were in the same location as the dermatologist identified lesions. Additionally, the ability to limit false positives was assessed by automatic assessment of the photographs from the no actinic keratosis group in comparison to the high actinic keratosis group. Results The correlation between the automatic and dermatologist counts was 0.62 on the face and 0.51 on the arms, compared to the dermatologist’s intra-observer variation of 0.83 and 0.93 for the same. Sensitivity of automatic detection was 39.5% on the face, 53.1% on the arms. Positive predictive values were 13.9% on the face and 39.8% on the arms. Significantly more lesions (p<0.0001) were detected in the high actinic keratosis group compared to the no actinic keratosis group. Conclusions The proposed method was inferior to assessment by the dermatologist in terms of sensitivity and positive predictive value. However, this pilot study used only a single simple feature and was still able to achieve sensitivity of detection of 53.1% on the arms.This suggests that image analysis is a feasible avenue of investigation for overcoming variability in clinical assessment. Future studies should focus on more sophisticated features to improve sensitivity for actinic keratoses without erythema and limit false positives associated with the anatomical structures on the face. PMID:25615930

  10. Down syndrome screening in assisted conception twins: an iatrogenic medical challenge.

    PubMed

    Ben-Ami, Ido; Maymon, Ron; Svirsky, Ran; Cuckle, Howard; Jauniaux, Eric

    2013-11-01

    The objective of this study was to provide a critical analysis of the impact of assisted conception on prenatal screening for Down syndrome (DS) in twin pregnancies and the value of various screening modalities for early detection of anomalies. The literature was searched using PubMed and the Cochrane Library focusing on prenatal screening and antenatal care of assisted-conception twin pregnancies. Serum screening alone is of limited value in detecting aneuploid twins, because the unaffected cotwin can "mask" the abnormal serum results of an affected one. In addition, this test can designate the pregnancy as at high risk but not identify the affected fetus. Nuchal translucency (NT) screening is the best available modality and a highly effective screening method for twin pregnancies. Among twins, NT alone has a 69% DS detection rate, first-trimester combined NT and serum biochemistry has a 72% DS detection rate, and an integrated screen will have an 80% DS detection rate at a 5% FPR. The data in the literature concerning the effect of assisted conception on maternal serum screening markers in twin pregnancies are scarce. Down syndrome screening in assisted-conception twins presents clinical and technical challenges. Therefore, assisted-conception twins need close monitoring from conception to delivery, by a practitioner familiar with the available screening modalities and their relative accuracy.

  11. Pesticide analysis using nanoceria-coated paper-based devices as a detection platform.

    PubMed

    Nouanthavong, Souksanh; Nacapricha, Duangjai; Henry, Charles S; Sameenoi, Yupaporn

    2016-03-07

    We report the first use of a paper-based device coated with nanoceria as a simple, low-cost and rapid detection platform for the analysis of organophosphate (OP) pesticides using an enzyme inhibition assay with acetylcholinesterase (AChE) and choline oxidase (ChOX). In the presence of acetylcholine, AChE and ChOX catalyze the formation of H2O2, which is detected colorimetrically by a nanoceria-coated device resulting in the formation of a yellow color. After incubation with OP pesticides, the AChE activity was inhibited, producing less H2O2, and a reduction in the yellow intensity. The assay is able to analyze OP pesticides without the use of sophisticated instruments and gives detection limits of 18 ng mL(-1) and 5.3 ng mL(-1) for methyl-paraoxon and chlorpyrifos-oxon, respectively. The developed method was successfully applied to detect methyl-paraoxon in spiked vegetables (cabbage) and a dried seafood product (dried green mussel), obtaining ∼95% recovery values for both sample types. The spiked samples were also analyzed using LC-MS/MS as a comparison to the developed method and similar values were obtained, indicating that the developed method gives accurate results and is suitable for OP analysis in real samples.

  12. Molecularly imprinted fluorescent hollow nanoparticles as sensors for rapid and efficient detection λ-cyhalothrin in environmental water.

    PubMed

    Wang, Jixiang; Qiu, Hao; Shen, Hongqiang; Pan, Jianming; Dai, Xiaohui; Yan, Yongsheng; Pan, Guoqing; Sellergren, Börje

    2016-11-15

    Molecularly imprinted fluorescent polymers have shown great promise in biological or chemical separations and detections, due to their high stability, selectivity and sensitivity. In this work, molecularly imprinted fluorescent hollow nanoparticles, which could rapidly and efficiently detect λ-cyhalothrin (a toxic insecticide) in water samples, was reported. The molecularly imprinted fluorescent sensor showed excellent sensitivity (the limit of detection low to 10.26nM), rapid detection rate (quantitative detection of λ-cyhalothrin within 8min), regeneration ability (maintaining good fluorescence properties after 8 cycling operation) and appreciable selectivity over several structural analogs. Moreover, the fluorescent sensor was further used to detect λ-cyhalothrin in real samples form the Beijing-Hangzhou Grand Canal Water. Despite the relatively complex components of the environmental water, the molecularly imprinted fluorescent hollow nanosensor still showed good recovery, clearly demonstrating the potential value of this smart sensor nanomaterial in environmental monitoring. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. A Novel Sensitive Luminescence Probe Microspheres for Rapid and Efficient Detection of τ-Fluvalinate in Taihu Lake

    PubMed Central

    Wang, Jixiang; Wang, Yunyun; Qiu, Hao; Sun, Lin; Dai, Xiaohui; Pan, Jianming; Yan, Yongsheng

    2017-01-01

    Fluorescent molecularly imprinted polymers have shown great promise in biological or chemical separations and detection, due to their high stability, selectivity and sensitivity. In this work, fluorescent molecularly imprinted microsphere was synthesized via precipitation polymerization, which could separate efficiently and rapidly detect τ-fluvalinate (a toxic insecticide) in water samples, was reported. The fluorescent imprinted sensor showed excellent stability, outstanding selectivity and the limit of detection low to 12.14 nM, good regeneration ability which still kept good sensitivity after 8 cycling experiments and fluorescence quenching mechanism was illustrated in details. In addition, the fluorescent sensor was further used to detect τ-fluvalinate in real samples from Taihu Lake. Despite the relatively complex components of the environment water, the fluorescent imprinted microspheres sitll showed good recovery, clearly demonstrating the potental value of this smart sensor nanomaterial in environment monitoring. PMID:28485402

  14. Liquid-phase exfoliated graphene as highly-sensitive sensor for simultaneous determination of endocrine disruptors: diethylstilbestrol and estradiol.

    PubMed

    Hu, Lintong; Cheng, Qin; Chen, Danchao; Ma, Ming; Wu, Kangbing

    2015-01-01

    It is quite important to develop convenient and rapid analytical methods for trace levels of endocrine disruptors because they heavily affect health and reproduction of humans and animals. Herein, graphene was easily prepared via one-step exfoliation using N-methyl-2-pyrrolidone as solvent, and then used to construct an electrochemical sensor for highly-sensitive detection of diethylstilbestrol (DES) and estradiol (E2). On the surface of prepared graphene film, two independent and greatly-increased oxidation waves were observed at 0.28V and 0.49V for DES and E2. The remarkable signal enlargements indicated that the detection sensitivity was improved significantly. The influences of pH value, amount of graphene and accumulation time on the oxidation signals of DES and E2 were discussed. As a result, a highly-sensitive and rapid electrochemical method was newly developed for simultaneous detection of DES and E2. The values of detection limit were evaluated to be 10.87 nM and 4.9 nM for DES and E2. Additionally, this new method was successfully used in lake water samples and the accuracy was satisfactory. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. Multiplexed detection of anthrax-related toxin genes.

    PubMed

    Moser, Michael J; Christensen, Deanna R; Norwood, David; Prudent, James R

    2006-02-01

    Simultaneous analysis of three targets in three colors on any real-time polymerase chain reaction (PCR) instrument would increase the flexibility of real-time PCR. For the detection of Bacillus strains that can cause inhalation anthrax-related illness, this ability would be valuable because two plasmids confer virulence, and internal positive controls are needed to monitor the testing in cases lacking target-specific signals. Using a real-time PCR platform called MultiCode-RTx, multiple assays were developed that specifically monitor the presence of Bacillus anthracis-specific virulence plasmid-associated genes. In particular for use on LightCycler-1, two triplex RTx systems demonstrated high sensitivity with limits of detection nearing single-copy levels for both plasmids. Specificity was established using a combination of Ct values and correct amplicon melting temperatures. All reactions were further verified by detection of an internal positive control. For these two triplex RTx assays, the analytical detection limit was one to nine plasmid copy equivalents, 100% analytical specificity with a 95% confidence interval (CI) of 9%, and 100% analytical sensitivity with a CI of 2%. Although further testing using clinical or environmental samples will be required to assess diagnostic sensitivity and specificity, the RTx platform achieves similar results to those of probe-based real-time systems.

  16. Dextran hydrogel coated surface plasmon resonance imaging (SPRi) sensor for sensitive and label-free detection of small molecule drugs

    NASA Astrophysics Data System (ADS)

    Li, Shaopeng; Yang, Mo; Zhou, Wenfei; Johnston, Trevor G.; Wang, Rui; Zhu, Jinsong

    2015-11-01

    The label-free and sensitive detection of small molecule drugs on SPRi is still a challenging task, mainly due to the limited surface immobilization capacity of the sensor. In this research, a dextran hydrogel-coated gold sensor chip for SPRi was successfully fabricated via photo-cross-linking for enhanced surface immobilization capacity. The density of the dextran hydrogel was optimized for protein immobilization and sensitive small molecule detection. The protein immobilization capacity of the hydrogel was 10 times greater than a bare gold surface, and 20 times greater than an 11-mercaptoundecanoic acid (MUA) surface. Such a drastic improvement in immobilization capacity allowed the SPRi sensor to detect adequate response signals when probing small molecule binding events. The binding signal of 4 nM liquid-phase biotin to streptavidin immobilized on the dextran surface reached 435 RU, while no response was observed on bare gold or MUA surfaces. The dextran hydrogel-coated SPRi sensor was also applied in a kinetic study of the binding between an immunosuppressive drug (FK506) and its target protein (FKBP12) in a high-throughput microarray format. The measured binding affinity was shown to be consistent with reported literature values, and a detection limit of 0.5 nM was achieved.

  17. Aspects of the Application of Cavity Enhanced Spectroscopy to Nitrogen Oxides Detection

    PubMed Central

    Wojtas, Jacek; Mikolajczyk, Janusz; Bielecki, Zbigniew

    2013-01-01

    This article presents design issues of high-sensitive laser absorption spectroscopy systems for nitrogen oxides (NOx) detection. Examples of our systems and their investigation results are also described. The constructed systems use one of the most sensitive methods, cavity enhanced absorption spectroscopy (CEAS). They operate at different wavelength ranges using a blue—violet laser diode (410 nm) as well as quantum cascade lasers (5.27 μm and 4.53 μm). Each of them is configured as a one or two channel measurement device using, e.g., time division multiplexing and averaging. During the testing procedure, the main performance features such as detection limits and measurements uncertainties have been determined. The obtained results are 1 ppb NO2, 75 ppb NO and 45 ppb N2O. For all systems, the uncertainty of concentration measurements does not exceed a value of 13%. Some experiments with explosives are also discussed. A setup equipped with a concentrator of explosives vapours was used. The detection method is based either on the reaction of the sensors to the nitrogen oxides directly emitted by the explosives or on the reaction to the nitrogen oxides produced during thermal decomposition of explosive vapours. For TNT, PETN, RDX and HMX a detection limit better than 1 ng has been achieved. PMID:23752566

  18. Event-specific qualitative and quantitative PCR detection of the GMO carnation (Dianthus caryophyllus) variety Moonlite based upon the 5'-transgene integration sequence.

    PubMed

    Li, P; Jia, J W; Jiang, L X; Zhu, H; Bai, L; Wang, J B; Tang, X M; Pan, A H

    2012-04-27

    To ensure the implementation of genetically modified organism (GMO)-labeling regulations, an event-specific detection method was developed based on the junction sequence of an exogenous integrant in the transgenic carnation variety Moonlite. The 5'-transgene integration sequence was isolated by thermal asymmetric interlaced PCR. Based upon the 5'-transgene integration sequence, the event-specific primers and TaqMan probe were designed to amplify the fragments, which spanned the exogenous DNA and carnation genomic DNA. Qualitative and quantitative PCR assays were developed employing the designed primers and probe. The detection limit of the qualitative PCR assay was 0.05% for Moonlite in 100 ng total carnation genomic DNA, corresponding to about 79 copies of the carnation haploid genome; the limit of detection and quantification of the quantitative PCR assay were estimated to be 38 and 190 copies of haploid carnation genomic DNA, respectively. Carnation samples with different contents of genetically modified components were quantified and the bias between the observed and true values of three samples were lower than the acceptance criterion (<25%) of the GMO detection method. These results indicated that these event-specific methods would be useful for the identification and quantification of the GMO carnation Moonlite.

  19. Design and analysis of a spectro-angular surface plasmon resonance biosensor operating in the visible spectrum

    NASA Astrophysics Data System (ADS)

    Filion-Côté, Sandrine; Roche, Philip J. R.; Foudeh, Amir M.; Tabrizian, Maryam; Kirk, Andrew G.

    2014-09-01

    Surface plasmon resonance (SPR) sensing is one of the most widely used methods to implement biosensing due to its sensitivity and capacity for label-free detection. Whilst most commercial SPR sensors operate in the angular regime, it has recently been shown that an increase in sensitivity and a greater robustness against noise can be achieved by measuring the reflectivity when varying both the angle and wavelength simultaneously, in a so-called spectro-angular SPR biosensor. A single value decomposition method is used to project the two-dimensional spectro-angular reflection signal onto a basis set and allow the image obtained from an unknown refractive index sample to be compared very accurately with a pre-calculated reference set. Herein we demonstrate that a previously reported system operated in the near infra-red has a lower detection limit when operating in the visible spectrum due to the improved spatial resolution and numerical precision of the image sensor. The SPR biosensor presented here has an experimental detection limit of 9.8 × 10-7 refractive index unit. To validate the system as a biosensor, we also performed the detection of synthetic RNA from pathogenic Legionella pneumophila with the developed biosensing platform.

  20. A comparison of simultaneous plasma, atomic absorption, and iron colorimetric determinations of major and trace constituents in acid mine waters

    USGS Publications Warehouse

    Ball, J.W.; Nordstrom, D. Kirk

    1994-01-01

    Sixty-three water samples collected during June to October 1982 from the Leviathan/Bryant Creek drainage basin were originally analyzed by simultaneous multielement direct-current plasma (DCP) atomic-emission spectrometry, flame atomic-absorption spectrometry, graphite-furnace atomic-absorption spectrometry (GFAAS) (thallium only), ultraviolet-visible spectrometry, and hydride-generation atomic-absorption spectrometry.Determinations were made for the following metallic and semi-metallic constituents: AI, As, B, Ba, Be, Bi, Cd, Ca, Cr, Co, Cu, Fe(11), Fe(total), Li, Pb, Mg, Mn, Mo, Ni, K, Sb, Se, Si, Na, Sr, TI, V, and Zn. These samples were re-analyzed later by simultaneous multielement inductively coupled plasma (ICP) atomic-emission spectrometry and Zeeman-corrected GFAAS to determine the concentrations of many of the same constituents with improved accuracy, precision, and sensitivity. The result of this analysis has been the generation of comparative concentration values for a significant subset of the solute constituents. Many of the more recently determined values replace less-than-detection values for the trace metals; others constitute duplicate analyses for the major constituents. The multiple determinations have yielded a more complete, accurate, and precise set of analytical data. They also have resulted in an opportunity to compare the performance of the plasma-emission instruments operated in their respective simultaneous multielement modes. Flame atomic-absorption spectrometry was judged best for Na and K and hydride-generation atomic-absorption spectrometry was judged best for As because of their lower detection limit and relative freedom from interelement spectral effects. Colorimetric determination using ferrozine as the color agent was judged most accurate, precise, and sensitive for Fe. Cadmium, lead, and vanadium concentrations were too low in this set of samples to enable a determination of whether ICP or DCP is a more suitable technique. Of the remaining elements, Ba, Be, Ca, Cr, Mg, Mn, Sr, and Zn have roughly equivalent accuracy, precision, and detection limit by ICP and DCP. Cobalt and Ni were determined to be better analyzed by ICP, because of lower detection limits; B, Cu, Mo, and Si were determined to be better analyzed by DCP, because of relative freedom from interferences. The determination oral by DCP was far more sensitive, owing to the use of a more sensitive wavelength, compared with the ICP. However, there is a very serious potential interference from a strong Ca emission line near the 396.15 nanometer DCP wavelength. Thus, there is no clear choice between the plasma techniques tested, for the determination oral. The ICP and DCP detection limits are typically between 0.001 and 0.5 milligrams per liter in acid mine waters. For those metals best analyzed by ICP and/or DCP, but below these limits, GFAAS is the method of choice because of its relatively greater sensitivity and specificity. Six of the elements were not determined by DCP, ICP or Zeeman-corrected GFAAS, and are not discussed in this report. These elements are: Bi, Fe(11), Li, Sb, Se, and TI.

  1. Evaluation of dried blood spot samples for screening of hepatitis C and human immunodeficiency virus in a real-world setting.

    PubMed

    Vázquez-Morón, Sonia; Ryan, Pablo; Ardizone-Jiménez, Beatriz; Martín, Dolores; Troya, Jesus; Cuevas, Guillermo; Valencia, Jorge; Jimenez-Sousa, María A; Avellón, Ana; Resino, Salvador

    2018-01-30

    Both hepatitis C virus (HCV) infection and human immunodeficiency virus (HIV) infection are underdiagnosed, particularly in low-income countries and in difficult-to-access populations. Our aim was to develop and evaluate a methodology for the detection of HCV and HIV infection based on capillary dry blood spot (DBS) samples taken under real-world conditions. We carried out a cross-sectional study of 139 individuals (31 healthy controls, 68 HCV-monoinfected patients, and 40 HCV/HIV-coinfected patients). ELISA was used for anti-HCV and anti-HIV antibody detection; and SYBR Green RT-PCR was used for HCV-RNA detection. The HIV serological analysis revealed 100% sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV). The HCV serological analysis revealed a sensitivity of 92.6%, specificity of 100%, PPV of 100%, and NPV of 79.5%. Finally, the HCV-RNA detection test revealed a detection limit of 5 copies/µl with an efficiency of 100% and sensitivity of 99.1%, specificity of 100%, PPV of 100%, and NPV of 96.9%. In conclusion, our methodology was able to detect both HCV infection and HIV infection from the same DBS sample with good diagnostic performance. Screening for HCV and HIV using DBS might be a key strategy in the implementation of national programs for the control of both infections.

  2. Added Value of SPECT/CT in the Evaluation of Benign Bone Diseases of the Appendicular Skeleton.

    PubMed

    Abikhzer, Gad; Srour, Saher; Keidar, Zohar; Bar-Shalom, Rachel; Kagna, Olga; Israel, Ora; Militianu, Daniela

    2016-04-01

    Bone scintigraphy is a sensitive technique to detect altered bone mineralization but has limited specificity. The use of SPECT/CT has improved significantly the diagnostic accuracy of bone scintigraphy, in patients with cancer as well as in evaluation of benign bone disease. It provides precise localization and characterization of tracer-avid foci, shortens the diagnostic workup, and decreases patient anxiety. Through both the SPECT and the CT components, SPECT/CT has an incremental value in characterizing benign bone lesions, specifically in the appendicular skeleton, as illustrated by present case series.

  3. Work environments and exposure to hazardous substances in korean tire manufacturing.

    PubMed

    Lee, Naroo; Lee, Byung-Kyu; Jeong, Sijeong; Yi, Gwang Yong; Shin, Jungah

    2012-06-01

    The purpose of this study is to evaluate the tire manufacturing work environments extensively and to identify workers' exposure to hazardous substances in various work processes. Personal air sampling was conducted to measure polycyclic aromatic hydrocarbons, carbon disulfide, 1,3-butadiene, styrene, methyl isobutyl ketone, methylcyclohexane, formaldehyde, sulfur dioxide, and rubber fume in tire manufacturing plants using the National Institute for Occupational Safety Health Manual of Analytical Methods. Noise, carbon monoxide, and heat stress exposure were evaluated using direct reading instruments. Past concentrations of rubber fume were assessed using regression analysis of total particulate data from 2003 to 2007, after identifying the correlation between the concentration of total particulate and rubber fume. Workers were exposed to rubber fume that exceeded 0.6 mg/m(3), the maximum exposure limit of the UK, in curing and production management processes. Forty-seven percent of workers were exposed to noise levels exceeding 85 dBA. Workers in the production management process were exposed to 28.1℃ (wet bulb globe temperature value, WBGT value) even when the outdoor atmosphere was 2.7℃ (WBGT value). Exposures to other substances were below the limit of detection or under a tenth of the threshold limit values given by the American Conference of Governmental Industrial Hygienists. To better classify exposure groups and to improve work environments, examining closely at rubber fume components and temperature as risk indicators in tire manufacturing is recommended.

  4. Cross-platform evaluation of commercial real-time SYBR green RT-PCR kits for sensitive and rapid detection of European bat Lyssavirus type 1.

    PubMed

    Picard-Meyer, Evelyne; Peytavin de Garam, Carine; Schereffer, Jean Luc; Marchal, Clotilde; Robardet, Emmanuelle; Cliquet, Florence

    2015-01-01

    This study evaluates the performance of five two-step SYBR Green RT-qPCR kits and five one-step SYBR Green qRT-PCR kits using real-time PCR assays. Two real-time thermocyclers showing different throughput capacities were used. The analysed performance evaluation criteria included the generation of standard curve, reaction efficiency, analytical sensitivity, intra- and interassay repeatability as well as the costs and the practicability of kits, and thermocycling times. We found that the optimised one-step PCR assays had a higher detection sensitivity than the optimised two-step assays regardless of the machine used, while no difference was detected in reaction efficiency, R (2) values, and intra- and interreproducibility between the two methods. The limit of detection at the 95% confidence level varied between 15 to 981 copies/µL and 41 to 171 for one-step kits and two-step kits, respectively. Of the ten kits tested, the most efficient kit was the Quantitect SYBR Green qRT-PCR with a limit of detection at 95% of confidence of 20 and 22 copies/µL on the thermocyclers Rotor gene Q MDx and MX3005P, respectively. The study demonstrated the pivotal influence of the thermocycler on PCR performance for the detection of rabies RNA, as well as that of the master mixes.

  5. Cross-Platform Evaluation of Commercial Real-Time SYBR Green RT-PCR Kits for Sensitive and Rapid Detection of European Bat Lyssavirus Type 1

    PubMed Central

    Picard-Meyer, Evelyne; Peytavin de Garam, Carine; Schereffer, Jean Luc; Marchal, Clotilde; Robardet, Emmanuelle; Cliquet, Florence

    2015-01-01

    This study evaluates the performance of five two-step SYBR Green RT-qPCR kits and five one-step SYBR Green qRT-PCR kits using real-time PCR assays. Two real-time thermocyclers showing different throughput capacities were used. The analysed performance evaluation criteria included the generation of standard curve, reaction efficiency, analytical sensitivity, intra- and interassay repeatability as well as the costs and the practicability of kits, and thermocycling times. We found that the optimised one-step PCR assays had a higher detection sensitivity than the optimised two-step assays regardless of the machine used, while no difference was detected in reaction efficiency, R 2 values, and intra- and interreproducibility between the two methods. The limit of detection at the 95% confidence level varied between 15 to 981 copies/µL and 41 to 171 for one-step kits and two-step kits, respectively. Of the ten kits tested, the most efficient kit was the Quantitect SYBR Green qRT-PCR with a limit of detection at 95% of confidence of 20 and 22 copies/µL on the thermocyclers Rotor gene Q MDx and MX3005P, respectively. The study demonstrated the pivotal influence of the thermocycler on PCR performance for the detection of rabies RNA, as well as that of the master mixes. PMID:25785274

  6. Impact of ERTS-1 images on management of New Jersey's coastal zone

    NASA Technical Reports Server (NTRS)

    Feinberg, E. B.; Yunghans, R. S.; Stitt, J. A.; Mairs, R. L.

    1974-01-01

    The thrust of New Jersey's ERTS investigation is development of procedures for operational use of ERTS-1 data by the Department of Environmental Protection in the management of the State's coastal zone. Four major areas of concern were investigated: detection of land use changes in the coastal zone; monitoring of offshore waste disposal; siting of ocean outfalls; and allocation of funds for shore protection. ERTS imagery was not useful for shore protection purposes; it was of limited practical value in the evaluation of offshore waste disposal and ocean outfall siting. However, ERTS imagery shows great promise for operational detection of land use changes in the coastal zone. Some constraints for practical change detection have been identified.

  7. Determination of perfluorinated alkyl acids in corn, popcorn and popcorn bags before and after cooking by focused ultrasound solid-liquid extraction, liquid chromatography and quadrupole-time of flight mass spectrometry.

    PubMed

    Moreta, Cristina; Tena, María Teresa

    2014-08-15

    An analytical method is proposed to determine ten perfluorinated alkyl acids (PFAAs) [nine perfluorocarboxylic acids (PFCAs) and perfluorooctane sulfonate (PFOS)] in corn, popcorn and microwave popcorn packaging by focused ultrasound solid-liquid extraction (FUSLE) and ultra high performance liquid chromatography (UHPLC) coupled to quadrupole-time of flight mass spectrometry (QTOF-MS/MS). Selected PFAAs were extracted efficiently in only one 10-s cycle by FUSLE, a simple, safe and inexpensive technique. The developed method was validated for microwave popcorn bags matrix as well as corn and popcorn matrices in terms of linearity, matrix effect error, detection and quantification limits, repeatability and recovery values. The method showed good accuracy with recovery values around 100% except for the lowest chain length PFAAs, satisfactory reproducibility with RSDs under 16%, and sensitivity with limits of detection in the order of hundreds picograms per gram of sample (between 0.2 and 0.7ng/g). This method was also applied to the analysis of six microwave popcorn bags and the popcorn inside before and after cooking. PFCAs contents between 3.50ng/g and 750ng/g were found in bags, being PFHxA (perfluorohexanoic acid) the most abundant of them. However, no PFAAs were detected either corn or popcorn, therefore no migration was assumed. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Measurement of 131I activity in thyroid of nuclear medical staff and internal dose assessment in a Polish nuclear medical hospital.

    PubMed

    Brudecki, K; Kowalska, A; Zagrodzki, P; Szczodry, A; Mroz, T; Janowski, P; Mietelski, J W

    2017-03-01

    This paper presents results of 131 I thyroid activity measurements in 30 members of the nuclear medicine personnel of the Department of Endocrinology and Nuclear Medicine Holy Cross Cancer Centre in Kielce, Poland. A whole-body spectrometer equipped with two semiconductor gamma radiation detectors served as the basic research instrument. In ten out of 30 examined staff members, the determined 131 I activity was found to be above the detection limit (DL = 5 Bq of 131 I in the thyroid). The measured activities ranged from (5 ± 2) Bq to (217 ± 56) Bq. The highest activities in thyroids were detected for technical and cleaning personnel, whereas the lowest values were recorded for medical doctors. Having measured the activities, an attempt has been made to estimate the corresponding annual effective doses, which were found to range from 0.02 to 0.8 mSv. The highest annual equivalent doses have been found for thyroid, ranging from 0.4 to 15.4 mSv, detected for a cleaner and a technician, respectively. The maximum estimated effective dose corresponds to 32% of the annual background dose in Poland, and to circa 4% of the annual limit for the effective dose due to occupational exposure of 20 mSv per year, which is in compliance with the value recommended by the International Commission on Radiological Protection.

  9. Flavoring exposure in food manufacturing

    PubMed Central

    Curwin, Brian D.; Deddens, Jim A.; McKernan, Lauralynn T.

    2015-01-01

    Flavorings are substances that alter or enhance the taste of food. Workers in the food-manufacturing industry, where flavorings are added to many products, may be exposed to any number of flavoring compounds. Although thousands of flavoring substances are in use, little is known about most of these in terms of worker health effects, and few have occupational exposure guidelines. Exposure assessment surveys were conducted at nine food production facilities and one flavor manufacturer where a total of 105 area and 74 personal samples were collected for 13 flavoring compounds including five ketones, five aldehydes, and three acids. The majority of the samples were below the limit of detection (LOD) for most compounds. Diacetyl had eight area and four personal samples above the LOD, whereas 2,3-pentanedione had three area samples above the LOD. The detectable values ranged from 25–3124 ppb and 15–172 ppb for diacetyl and 2,3-pentanedione respectively. These values exceed the proposed National Institute for Occupational Safety and Health (NIOSH) recommended exposure limit for these compounds. The aldehydes had the most detectable samples, with each of them having >50% of the samples above the LOD. Acetaldehyde had all but two samples above the LOD, however, these samples were below the OSHA PEL. It appears that in the food-manufacturing facilities surveyed here, exposure to the ketones occurs infrequently, however levels above the proposed NIOSH REL were found. Conversely, aldehyde exposure appears to be ubiquitous. PMID:25052692

  10. Electrochemical immunosensor based on poly (3,4-ethylenedioxythiophene) modified with gold nanoparticle to detect aflatoxin B1.

    PubMed

    Sharma, Arati; Kumar, A; Khan, Raju

    2017-07-01

    Gold nanoparticles (Au-NPs) functionalized Poly (3,4-ethylenedioxythiophene) (PEDOT) bioelectrodes were fabricated layer by layer deposition on ITO electrode for detection of aflatoxin B 1 . The monoclonal anti-aflatoxin antibodies (Anti-AFB 1 ) were immobilized over the surface of PEDOT/Au-NPs/ITO using EDC/NHS coupling. The surface morphology and characteristics of the modified electrodes were investigated by scanning electron microscope and contact angle measurements. The electrochemical analysis of the fabricated immunoelectrode and the immobilization of the antibodies have been evaluated and confirmed by performing Cyclic Voltammetry (CV), Electrochemical Impedance Spectroscopy (EIS) and Fourier Transform Infrared Spectroscopy (FTIR). Decrease in the value of electron transfer resistance (R et ) and increase in the peak current values after incorporation of Au-NPs signifies the enhanced properties of PEDOT embedded Au-NPs. The heterogeneous rate constant (k s ) and transfer coefficient (α) have been determined by using Laviron's method. The fabricated immunosensor exhibits high sensitive amperometric response of 3.72μAngmL -1 towards AFB 1 concentration in a linear range of 1-25ngmL -1 with detection limit (LOD) of 0.0045ngmL -1 and limit of quantification (LOQ) of 0.0156ngmL -1 . The fabricated immunoelectrode shows a reproducibility of 96.13% and 94.5% towards real maize sample spiked with AFB 1 of concentration 30ngmL -1 and 50ngmL -1 , respectively. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Multiple symbol partially coherent detection of MPSK

    NASA Technical Reports Server (NTRS)

    Simon, M. K.; Divsalar, D.

    1992-01-01

    It is shown that by using the known (or estimated) value of carrier tracking loop signal to noise ratio (SNR) in the decision metric, it is possible to improve the error probability performance of a partially coherent multiple phase-shift-keying (MPSK) system relative to that corresponding to the commonly used ideal coherent decision rule. Using a maximum-likeihood approach, an optimum decision metric is derived and shown to take the form of a weighted sum of the ideal coherent decision metric (i.e., correlation) and the noncoherent decision metric which is optimum for differential detection of MPSK. The performance of a receiver based on this optimum decision rule is derived and shown to provide continued improvement with increasing length of observation interval (data symbol sequence length). Unfortunately, increasing the observation length does not eliminate the error floor associated with the finite loop SNR. Nevertheless, in the limit of infinite observation length, the average error probability performance approaches the algebraic sum of the error floor and the performance of ideal coherent detection, i.e., at any error probability above the error floor, there is no degradation due to the partial coherence. It is shown that this limiting behavior is virtually achievable with practical size observation lengths. Furthermore, the performance is quite insensitive to mismatch between the estimate of loop SNR (e.g., obtained from measurement) fed to the decision metric and its true value. These results may be of use in low-cost Earth-orbiting or deep-space missions employing coded modulations.

  12. Fully automated analytical procedure for propofol determination by sequential injection technique with spectrophotometric and fluorimetric detections.

    PubMed

    Šrámková, Ivana; Amorim, Célia G; Sklenářová, Hana; Montenegro, Maria C B M; Horstkotte, Burkhard; Araújo, Alberto N; Solich, Petr

    2014-01-01

    In this work, an application of an enzymatic reaction for the determination of the highly hydrophobic drug propofol in emulsion dosage form is presented. Emulsions represent a complex and therefore challenging matrix for analysis. Ethanol was used for breakage of a lipid emulsion, which enabled optical detection. A fully automated method based on Sequential Injection Analysis was developed, allowing propofol determination without the requirement of tedious sample pre-treatment. The method was based on spectrophotometric detection after the enzymatic oxidation catalysed by horseradish peroxidase and subsequent coupling with 4-aminoantipyrine leading to a coloured product with an absorbance maximum at 485 nm. This procedure was compared with a simple fluorimetric method, which was based on the direct selective fluorescence emission of propofol in ethanol at 347 nm. Both methods provide comparable validation parameters with linear working ranges of 0.005-0.100 mg mL(-1) and 0.004-0.243 mg mL(-1) for the spectrophotometric and fluorimetric methods, respectively. The detection and quantitation limits achieved with the spectrophotometric method were 0.0016 and 0.0053 mg mL(-1), respectively. The fluorimetric method provided the detection limit of 0.0013 mg mL(-1) and limit of quantitation of 0.0043 mg mL(-1). The RSD did not exceed 5% and 2% (n=10), correspondingly. A sample throughput of approx. 14 h(-1) for the spectrophotometric and 68 h(-1) for the fluorimetric detection was achieved. Both methods proved to be suitable for the determination of propofol in pharmaceutical formulation with average recovery values of 98.1 and 98.5%. © 2013 Elsevier B.V. All rights reserved.

  13. Determination of flavonoids from Orthosiphon stamineus in plasma using a simple HPLC method with ultraviolet detection.

    PubMed

    Loon, Yit Hong; Wong, Jia Woei; Yap, Siew Ping; Yuen, Kah Hay

    2005-02-25

    A simple liquid chromatographic method was developed for the simultaneous determination of flavonoids from Orthosiphon stamineus Benth, namely sinensitin, eupatorin and 3'-hydroxy-5,6,7,4'-tetramethoxyflavone, in plasma. Prior to analysis, the flavonoids and the internal standard (naproxen) were extracted from plasma samples using a 1:1 mixture of ethyl acetate and chloroform. The detection and quantification limits for the three flavonoids were similar being 3 and 5 ng/ml, respectively. The within-day and between-day accuracy values, expressed as percentage of true values, for the three flavonoids were between 95 and 107%, while the corresponding precision, expressed as coefficients of variation, for the three flavonoids were less than 14%. In addition, the mean recovery values of the extraction procedure for all the flavonoids were between 92 and 114%. The calibration curves were linear over a concentration range of 5-4000 ng/ml. The present method was applied to analyse plasma samples obtained from a pilot study using rats in which the mean absolute oral bioavailability values for sinensitin, eupatorin and 3'-hydroxy-5,6,7,4'-tetramethoxyflavone was 9.4, 1.0 and 1.5%, respectively.

  14. Clinical application of diffusion tensor magnetic resonance imaging in skeletal muscle

    PubMed Central

    Longwei, Xu

    2012-01-01

    Summary Diffusion tensor magnetic resonance imaging (DTI) is increasingly applied in the detection and characterization of skeletal muscle. This promising technique has aroused much enthusiasm and generated high expectations, because it is able to provide some specific information of skeletal muscle that is not available from other imaging modalities. Compared with conventional MRI, DTI could reconstruct the trajectories of skeletal muscle fibers. It makes it possible to non-invasively detect several physiological values (diffusion values), like fractional anisotropy (FA) and apparent diffusion coefficient (ADC), which have a great association with the muscle physiology and pathology. Furthermore, other advantages of DTI are the capability of investigating the muscle biomechanics and also investigate the pathological condition of skeletal muscle. Finally, several challenges, which limit the wide application of DTI in skeletal muscle, were discussed. It is believed that this review may arouse in-depth studies on the clinical application of DTI in skeletal muscle in future. PMID:23738269

  15. Development of gait segmentation methods for wearable foot pressure sensors.

    PubMed

    Crea, S; De Rossi, S M M; Donati, M; Reberšek, P; Novak, D; Vitiello, N; Lenzi, T; Podobnik, J; Munih, M; Carrozza, M C

    2012-01-01

    We present an automated segmentation method based on the analysis of plantar pressure signals recorded from two synchronized wireless foot insoles. Given the strict limits on computational power and power consumption typical of wearable electronic components, our aim is to investigate the capability of a Hidden Markov Model machine-learning method, to detect gait phases with different levels of complexity in the processing of the wearable pressure sensors signals. Therefore three different datasets are developed: raw voltage values, calibrated sensor signals and a calibrated estimation of total ground reaction force and position of the plantar center of pressure. The method is tested on a pool of 5 healthy subjects, through a leave-one-out cross validation. The results show high classification performances achieved using estimated biomechanical variables, being on average the 96%. Calibrated signals and raw voltage values show higher delays and dispersions in phase transition detection, suggesting a lower reliability for online applications.

  16. ROC analysis of diagnostic performance in liver scintigraphy.

    PubMed

    Fritz, S L; Preston, D F; Gallagher, J H

    1981-02-01

    Studies on the accuracy of liver scintigraphy for the detection of metastases were assembled from 38 sources in the medical literature. An ROC curve was fitted to the observed values of sensitivity and specificity using an algorithm developed by Ogilvie and Creelman. This ROC curve fitted the data better than average sensitivity and specificity values in each of four subsets of the data. For the subset dealing with Tc-99m sulfur colloid scintigraphy, performed for detection of suspected metastases and containing data on 2800 scans from 17 independent series, it was not possible to reject the hypothesis that interobserver variation was entirely due to the use of different decision thresholds by the reporting clinicians. Thus the ROC curve obtained is a reasonable baseline estimate of the performance potentially achievable in today's clinical setting. Comparison of new reports with these data is possible, but is limited by the small sample sizes in most reported series.

  17. Sensitive and rapid determination of quinoline yellow in drinks using polyvinylpyrrolidone-modified electrode.

    PubMed

    Zhang, Shenghui; Shi, Zhen; Wang, Jinshou

    2015-04-15

    A novel electrochemical sensor using polyvinylpyrrolidone (PVP)-modified carbon paste electrode was developed for the sensitive and rapid determination of quinoline yellow. In 0.1M, pH 6.5 phosphate buffer, an irreversible oxidation wave at 0.97 V was observed for quinoline yellow. PVP exhibited strong accumulation ability to quinoline yellow, and consequently increased the oxidation peak current of quinoline yellow remarkably. The effects of pH value, amount of PVP, accumulation potential and time were studied on the oxidation signals of quinoline yellow. The linear range was from 5×10(-8) to 1×10(-6) M, and the limit of detection was evaluated to be 2.7×10(-8) M. It was used to detect quinoline yellow in different drink samples, and the results consisted with the values that obtained by high-performance liquid chromatography. Copyright © 2014 Elsevier Ltd. All rights reserved.

  18. Survey parameters for detecting 21cm - Lyα emitter cross correlations with the Square Kilometre Array

    NASA Astrophysics Data System (ADS)

    Hutter, Anne; Trott, Cathryn M.; Dayal, Pratika

    2018-06-01

    Detections of the cross correlation signal between the 21cm signal during reionization and high-redshift Lyman Alpha emitters (LAEs) are subject to observational uncertainties which mainly include systematics associated with radio interferometers and LAE selection. These uncertainties can be reduced by increasing the survey volume and/or the survey luminosity limit, i.e. the faintest detectable Lyman Alpha (Lyα) luminosity. We use our model of high-redshift LAEs and the underlying reionization state to compute the uncertainties of the 21cm-LAE cross correlation function at z ≃ 6.6 for observations with SKA1-Low and LAE surveys with Δz = 0.1 for three different values of the average IGM ionization state (⟨χHI⟩≃ 0.1, 0.25, 0.5). At z ≃ 6.6, we find SILVERRUSH type surveys, with a field of view of 21 deg2 and survey luminosity limits of Lα ≥ 7.9 × 1042erg s-1, to be optimal to distinguish between an inter-galactic medium (IGM) that is 50%, 25% and 10% neutral, while surveys with smaller fields of view and lower survey luminosity limits, such as the 5 and 10 deg2 surveys with WFIRST, can only discriminate between a 50% and 10% neutral IGM.

  19. Combining markers with and without the limit of detection

    PubMed Central

    Dong, Ting; Liu, Catherine Chunling; Petricoin, Emanuel F.; Tang, Liansheng Larry

    2014-01-01

    In this paper, we consider the combination of markers with and without the limit of detection (LOD). LOD is often encountered when measuring proteomic markers. Because of the limited detecting ability of an equipment or instrument, it is difficult to measure markers at a relatively low level. Suppose that after some monotonic transformation, the marker values approximately follow multivariate normal distributions. We propose to estimate distribution parameters while taking the LOD into account, and then combine markers using the results from the linear discriminant analysis. Our simulation results show that the ROC curve parameter estimates generated from the proposed method are much closer to the truth than simply using the linear discriminant analysis to combine markers without considering the LOD. In addition, we propose a procedure to select and combine a subset of markers when many candidate markers are available. The procedure based on the correlation among markers is different from a common understanding that a subset of the most accurate markers should be selected for the combination. The simulation studies show that the accuracy of a combined marker can be largely impacted by the correlation of marker measurements. Our methods are applied to a protein pathway dataset to combine proteomic biomarkers to distinguish cancer patients from non-cancer patients. PMID:24132938

  20. A gain and bandwidth enhanced transimpedance preamplifier for Fourier-transform ion cyclotron resonance mass spectrometry

    PubMed Central

    Lin, Tzu-Yung; Green, Roger J.; O'Connor, Peter B.

    2011-01-01

    The nature of the ion signal from a 12-T Fourier-transform ion cyclotron resonance mass spectrometer and the electronic noise were studied to further understand the electronic detection limit. At minimal cost, a new transimpedance preamplifier was designed, computer simulated, built, and tested. The preamplifier design pushes the electronic signal-to-noise performance at room temperature to the limit, because of its enhanced tolerance of the capacitance of the detection device, lower intrinsic noise, and larger flat mid-band gain (input current noise spectral density of around 1 pA/\\documentclass[12pt]{minimal}\\begin{document}$\\sqrt{\\mbox{Hz}}$\\end{document}Hz when the transimpedance is about 85 dBΩ). The designed preamplifier has a bandwidth of ∼3 kHz to 10 MHz, which corresponds to the mass-to-charge ratio, m/z, of approximately 18 to 61 k at 12 T. The transimpedance and the bandwidth can be easily adjusted by changing the value of passive components. The feedback limitation of the circuit is discussed. With the maximum possible transimpedance of 5.3 MΩ when using an 0402 surface mount resistor, the preamplifier was estimated to be able to detect ∼110 charges in a single scan. PMID:22225232

  1. Determination of Detection Limits and Quantitation Limits for Compounds in a Database of GC/MS by FUMI Theory

    PubMed Central

    Nakashima, Shinya; Hayashi, Yuzuru

    2016-01-01

    The aim of this paper is to propose a stochastic method for estimating the detection limits (DLs) and quantitation limits (QLs) of compounds registered in a database of a GC/MS system and prove its validity with experiments. The approach described in ISO 11843 Part 7 is adopted here as an estimation means of DL and QL, and the decafluorotriphenylphosphine (DFTPP) tuning and retention time locking are carried out for adjusting the system. Coupled with the data obtained from the system adjustment experiments, the information (noise and signal of chromatograms and calibration curves) stored in the database is used for the stochastic estimation, dispensing with the repetition measurements. Of sixty-six pesticides, the DL values obtained by the ISO method were compared with those from the statistical approach and the correlation between them was observed to be excellent with the correlation coefficient of 0.865. The accuracy of the method proposed was also examined and concluded to be satisfactory as well. The samples used are commercial products of pesticides mixtures and the uncertainty from sample preparation processes is not taken into account. PMID:27162706

  2. Susceptibility-matched plugs for microcoil NMR probes

    NASA Astrophysics Data System (ADS)

    Kc, Ravi; Gowda, Yashas N.; Djukovic, Danijel; Henry, Ian D.; Park, Gregory H. J.; Raftery, Daniel

    2010-07-01

    For mass-limited samples, the residual sample volume outside the detection coil is an important concern, as is good base line resolution. Here, we present the construction and evaluation of magnetic susceptibility-matched plugs for microcoil NMR sample cells which address these issues. Mixed-epoxy glue and ultem tube plugs that have susceptibility values close to those of perfluorocarbon FC-43 (fluorinert) and copper were used in small volume (0.5-2 μL) and larger volume (15-20 μL) thin glass capillary sample cells. Using these plugs, the sample volume efficiency (i.e. ratio of active volume to total sample volume in the microcoil NMR cell) was improved by 6-12-fold without sensitivity and resolution trade-offs. Comparison with laser etched or heat etched microcoil sample cells is provided. The approaches described are potentially useful in metabolomics for biomarkers detection in mass limited biological samples.

  3. Susceptibility-matched plugs for microcoil NMR probes.

    PubMed

    Kc, Ravi; Gowda, Yashas N; Djukovic, Danijel; Henry, Ian D; Park, Gregory H J; Raftery, Daniel

    2010-07-01

    For mass-limited samples, the residual sample volume outside the detection coil is an important concern, as is good base line resolution. Here, we present the construction and evaluation of magnetic susceptibility-matched plugs for microcoil NMR sample cells which address these issues. Mixed-epoxy glue and ultem tube plugs that have susceptibility values close to those of perfluorocarbon FC-43 (fluorinert) and copper were used in small volume (0.5-2 microL) and larger volume (15-20 microL) thin glass capillary sample cells. Using these plugs, the sample volume efficiency (i.e. ratio of active volume to total sample volume in the microcoil NMR cell) was improved by 6-12-fold without sensitivity and resolution trade-offs. Comparison with laser etched or heat etched microcoil sample cells is provided. The approaches described are potentially useful in metabolomics for biomarkers detection in mass limited biological samples. Copyright (c) 2010 Elsevier Inc. All rights reserved.

  4. Susceptibility-matched plugs for microcoil NMR probes

    PubMed Central

    Kc, Ravi; Gowda, Yashas N.; Djukovic, Danijel; Henry, Ian D; Park, Gregory H J; Raftery, Daniel

    2010-01-01

    For mass limited samples, the residual sample volume outside the detection coil is an important concern, as is good base line resolution. Here, we present the construction and evaluation of magnetic susceptibility-matched plugs for microcoil NMR sample cells which address these issues. Mixed-epoxy glue and ultem tube plugs that have susceptibility values close to those of perfluorocarbon FC-43 (fluorinert) and copper were used in small volume (0.5 to 2 μL) and larger volume (15 to 20 μL) thin glass capillary sample cells. Using these plugs, the sample volume efficiency (i.e. ratio of active volume to total sample volume in the microcoil NMR cell) was improved by 6 to 12 fold without sensitivity and resolution trade-offs. Comparison with laser etched or heat etched microcoil sample cells is provided. The approaches described are potentially useful in metabolomics for biomarkers detection in mass limited biological samples. PMID:20510638

  5. Characterization of X80 and X100 Microalloyed Pipeline Steel Using Quantitative X-ray Diffraction

    NASA Astrophysics Data System (ADS)

    Wiskel, J. B.; Li, X.; Ivey, D. G.; Henein, H.

    2018-06-01

    Quantitative X-ray diffraction characterization of four (4) X80 and three (3) X100 microalloyed steels was undertaken. The effect of through-thickness position, processing parameters, and composition on the measured crystallite size, microstrain, and J index (relative magnitude of crystallographic texture) was determined. Microstructure analysis using optical microscopy, scanning electron microscopy, transmission electron microscopy, and electron-backscattered diffraction was also undertaken. The measured value of microstrain increased with increasing alloy content and decreasing cooling interrupt temperature. Microstructural features corresponding to crystallite size in the X80 steels were both above and below the detection limit for quantitative X-ray diffraction. The X100 steels consistently exhibited microstructure features below the crystallite size detection limit. The yield stress of each steel increased with increasing microstrain. The increase in microstrain from X80 to X100 is also associated with a change in microstructure from predominantly polygonal ferrite to bainitic ferrite.

  6. Determination of enrofloxacin by room-temperature phosphorimetry after solid phase extraction on an acrylic polymer sorbent

    NASA Astrophysics Data System (ADS)

    de Souza, Cabrini F.; Martins, Renata K. S.; da Silva, Andrea R.; da Cunha, Alessandra L. M. C.; Aucélio, Ricardo Q.

    A phosphorimetric method was developed to enable the determination of enrofloxacin using photochemical derivatization which was used to both improve detection limits and to minimize the uncertainty of measurements. Phosphorescence was induced on cellulose containing TlNO3. Absolute limit of detection at the ng range and linear analytical response over three orders of magnitude were achieved. A metrological study was made to obtain the combined uncertainty value and to identify that the precision was mainly affected by the changing of substrates when measuring the signal from each replicate. Pharmaceutical formulations containing enrofloxacin were successfully analyzed by the method and the results were similar to the ones achieved using a HPLC method. A solid phase extraction on an acrylic polymer was optimized to separate enrofloxacin from interferents such as diclofenac and other components from biological matrices, which allowed the successful use of the method in urine analysis.

  7. Determination of organophosphorus pesticides in bovine tissue by an on-line coupled matrix solid-phase dispersion-solid phase extraction-high performance liquid chromatography with diode array detection method.

    PubMed

    Gutiérrez Valencia, Tania M; García de Llasera, Martha P

    2011-09-28

    A miniaturized method based on matrix solid-phase dispersion coupled to solid phase extraction and high performance liquid chromatography with diode array detection (MSPD-SPE-HPLC/DAD) was developed for the trace simultaneous determination of the following organophosphorus pesticides (OPPs) in bovine tissue: parathion-methyl, fenitrothion, parathion, chlorfenvinphos, diazinon, ethion, fenchlorphos, chlorpyrifos and carbophenothion. To perform the coupling between MSPD and SPE, 0.05 g of sample was dispersed with 0.2 g of C(18) silica sorbent and packed into a stainless steel cartridge containing 0.05 g of silica gel in the bottom. After a clean-up of high and medium polarity interferences with water and an acetonitrile:water mixture, the OPPs were desorbed from the MSPD cartridge with pure acetonitrile and directly transferred to a dynamic mixing chamber for dilution with water and preconcentration into an SPE 20 mm × 2.0 mm I.D. C(18) silica column. Subsequently, the OPPs were eluted on-line with the chromatographic mobile phase to the analytical column and the diode array detector for their separation and detection, respectively. The method was validated and yielded recovery values between 91% and 101% and precision values, expressed as relative standard deviations (RSD), which were less than or equal to 12%. Linearity was good and ranged from 0.5 to 10 μg g(-1), and the limits of detection of the OPPs were in the range of 0.04-0.25 μg g(-1). The method was satisfactorily applied to the analysis of real samples and is recommended for food control, research efforts when sample amounts are limited, and laboratories that have ordinary chromatographic instrumentation. Copyright © 2011 Elsevier B.V. All rights reserved.

  8. Comparison of a pocket-size ultrasound device with a premium ultrasound machine: diagnostic value and time required in bedside ultrasound examination.

    PubMed

    Stock, Konrad Friedrich; Klein, Bettina; Steubl, Dominik; Lersch, Christian; Heemann, Uwe; Wagenpfeil, Stefan; Eyer, Florian; Clevert, Dir-Andre

    2015-10-01

    Time savings and clinical accuracy of a new miniature ultrasound device was investigated utilizing comparison with conventional high-end ultrasound instruments. Our objective was to determine appropriate usage and limitations of this diagnostic tool in internal medicine. We investigated 28 patients from the internal-medicine department. Patients were examined with the Acuson P10 portable device and a Sonoline Antares instrument in a cross-over design. All investigations were carried out at the bedside; the results were entered on a standardized report form. The time for the ultrasound examination (transfer time, setting up and disassembly, switching on and off, and complete investigation time) was recorded separately. Mean time for overall examination per patient with the portable ultrasound device was shorter (25.0 ± 4.5 min) than with the high-end machine (29.4 ± 4.4 min; p < 0.001). When measuring the size of liver, spleen, and kidneys, the values obtained differed significantly between portable device and the high-end instrument. In our study, we identified 113 pathological ultrasound findings with the high-end ultrasound machine, while 82 pathological findings (73%) were concordantly detected with the portable ultrasound device. The main diagnostic strengths of the portable device were in the detection of ascites (sensitivity 80%), diagnosis of fatty liver, and identification of severe parenchymal liver damage. The clinical utility of portable ultrasound machines is limited. There will be clinical roles for distinct clinical questions such as detection of ascites or pleural effusion when used by experienced examiners. However, sensitivity in detecting multiple pathologies is not comparable to high-end ultrasound machines.

  9. An assessment of water quality and microbial risk in Rio Grande Basin in the United States-Mexican border region.

    PubMed

    Ryu, Hodon; Alum, Absar; Alvarez, Maria; Mendoza, Jose; Abbaszadegan, Morteza

    2005-06-01

    Increased reliance of urban populations on Rio Grande water has necessitated an expanded microbial surveillance of the river to help identify and evaluate sources of human pathogens, which could pose a public health risk. The objectives of this study were to investigate microbial and chemical water quality in Rio Grande water and to perform risk assessment analyses for Cryptosporidium. No oocysts in any of the ten-litre samples were detected. However, the limit of detection in the water samples ranged between 20 and 200 oocysts/100 L. The limits of detection obtained in this study would result in one to two orders of magnitude higher risk of infection for Cryptosporidium than the U.S.EPA annual acceptable risk level of 10(-4). The bacterial data showed the significance of animal farming and raw sewage as sources of fecal pollution. Male specific and somatic coliphages were detected in 52% (11/21) and 62% (24/39) of the samples, respectively. Somatic coliphages were greater by one order of magnitude, and were better correlated with total (r2 = 0.6801; p < or = 0.05) and fecal coliform bacteria (r2 = 0.7366; p < or = 0.05) than male specific coliphages. The dissolved organic carbon (DOC) and specific ultraviolet absorbance (SUVA) values ranged 2.58-5.59mg/L and 1.23-2.29 m(-1) (mg/I)(-1), respectively. Low SUVA values of raw water condition make it difficult to remove DOC during physical and chemical treatment processes. The microbial and chemical data provided from this study can help drinking water utilities to maintain balance between greater microbial inactivation and reduced disinfection by-products (DBPs) formation.

  10. Retrospective observation on contribution and limitations of screening for breast cancer with mammography in Korea: detection rate of breast cancer and incidence rate of interval cancer of the breast.

    PubMed

    Lee, Kunsei; Kim, Hyeongsu; Lee, Jung Hyun; Jeong, Hyoseon; Shin, Soon Ae; Han, Taehwa; Seo, Young Lan; Yoo, Youngbum; Nam, Sang Eun; Park, Jong Heon; Park, Yoo Mi

    2016-11-18

    The purpose of this study was to determine the benefits and limitations of screening for breast cancer using mammography. Descriptive design with follow-up was used in the study. Data from breast cancer screening and health insurance claim data were used. The study population consisted of all participants in breast cancer screening from 2009 to 2014. Crude detection rate, positive predictive value and sensitivity and specificity of breast cancer screening and, incidence rate of interval cancer of the breast were calculated. The crude detection rate of breast cancer screening per 100,000 participants increased from 126.3 in 2009 to 182.1 in 2014. The positive predictive value of breast cancer screening per 100,000 positives increased from 741.2 in 2009 to 1,367.9 in 2014. The incidence rate of interval cancer of the breast per 100,000 negatives increased from 51.7 in 2009 to 76.3 in 2014. The sensitivities of screening for breast cancer were 74.6% in 2009 and 75.1% in 2014 and the specificities were 83.1% in 2009 and 85.7% in 2014. To increase the detection rate of breast cancer by breast cancer screening using mammography, the participation rate should be higher and an environment where accurate mammography and reading can be performed and reinforcement of quality control are required. To reduce the incidence rate of interval cancer of the breast, it will be necessary to educate women after their 20s to perform self-examination of the breast once a month regardless of participation in screening for breast cancer.

  11. Optimization and validation of CEDIA drugs of abuse immunoassay tests in serum on Hitachi 912.

    PubMed

    Kirschbaum, Katrin M; Musshoff, Frank; Schmithausen, Ricarda; Stockhausen, Sarah; Madea, Burkhard

    2011-10-10

    Due to sensitive limits of detection of chromatographic methods and low limit values regarding the screening of drugs under the terms of impairment in safe driving (§ 24a StVG, Street Traffic Law in Germany), preliminary immunoassay (IA) tests should be able to detect also low concentrations of legal and illegal drugs in serum in forensic cases. False-negatives should be avoided, the rate of false-positive samples should be low due to cost and time. An optimization of IA cutoff values and a validation of the assay is required for each laboratory. In a retrospective study results for serum samples containing amphetamine, methylenedioxy derivatives, cannabinoids, benzodiazepines, cocaine (metabolites), methadone and opiates obtained with CEDIA drugs of abuse reagents on a Hitachi 912 autoanalyzer were compared with quantitative results of chromatographic methods (gas or liquid chromatography coupled with mass spectrometry (GC/MS or LC/MS)). Firstly sensitivity, specificity, positive and negative predictive values and overall misclassification rates were evaluated by contingency tables and compared to ROC-analyses and Youden-Indices. Secondly ideal cutoffs were statistically calculated on the basis of sensitivity and specificity as decisive statistical criteria with focus on a high sensitivity (low rates of false-negatives), i.e. using the Youden-Index. Immunoassay (IA) and confirmatory results were available for 3014 blood samples. Sensitivity was 90% or more for nearly all analytes: amphetamines (IA cutoff 9.5 ng/ml), methylenedioxy derivatives (IA cutoff 5.5 ng/ml), cannabinoids (IA cutoff 14.5 ng/ml), benzodiazepines (IA cutoff >0 ng/ml). Test of opiates showed a sensitivity of 86% for a IA cutoff value of >0 ng/ml. Values for specificity ranged between 33% (methadone, IA cutoff 10 ng/ml) and 90% (cocaine, IA cutoff 20 ng/ml). Lower cutoff values as recommended by ROC analyses were chosen for most tests to decrease the rate of false-negatives. Analyses enabled the definition of cutoff values with good values for sensitivity. Small rates of false-positives can be accepted in forensic cases. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  12. Effect of Metal Artifacts on Detection of Vertical Root Fractures Using Two Cone Beam Computed Tomography Systems.

    PubMed

    Safi, Yaser; Aghdasi, Mohammad Mehdi; Ezoddini-Ardakani, Fatemeh; Beiraghi, Samira; Vasegh, Zahra

    2015-01-01

    Vertical root fracture (VRF) is common in endodontically treated teeth. Conventional and digital radiographies have limitations for detection of VRFs. Cone-beam computed tomography (CBCT) offers greater detection accuracy of VRFs in comparison with conventional radiography. This study compared the effects of metal artifacts on detection of VRFs by using two CBCT systems. Eighty extracted premolars were selected and sectioned at the level of the cemento enamel junction (CEJ). After preparation, root canals were filled with gutta-percha. Subsequently, two thirds of the root fillings were removed for post space preparation and a custom-made post was cemented into each canal. The teeth were randomly divided into two groups (n=40). In the test group, root fracture was created with Instron universal testing machine. The control teeth remained intact. CBCT scans of all teeth were obtained with either New Tom VGI or Soredex Scanora 3D. Three observers analyzed the images for detection of VRF. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) for VRF detection and percentage of probable cases were calculated for each imaging system and compared using non-parametric tests considering the non-normal distribution of data. The inter-observer reproducibility was calculated using the weighted kappa coefficient. There were no statistically significant differences in sensitivity, specificity, PPV and NPV between the two CBCT systems. The effect of metal artifacts on VRF detection was not significantly different between the two CBCT systems.

  13. Comparison of direct 13C and indirect 1H-[13C] MR detection methods for the study of dynamic metabolic turnover in the human brain

    NASA Astrophysics Data System (ADS)

    Chen, Hao; De Feyter, Henk M.; Brown, Peter B.; Rothman, Douglas L.; Cai, Shuhui; de Graaf, Robin A.

    2017-10-01

    A wide range of direct 13C and indirect 1H-[13C] MR detection methods exist to probe dynamic metabolic pathways in the human brain. Choosing an optimal detection method is difficult as sequence-specific features regarding spatial localization, broadband decoupling, spectral resolution, power requirements and sensitivity complicate a straightforward comparison. Here we combine density matrix simulations with experimentally determined values for intrinsic 1H and 13C sensitivity, T1 and T2 relaxation and transmit efficiency to allow selection of an optimal 13C MR detection method for a given application and magnetic field. The indirect proton-observed, carbon-edited (POCE) detection method provides the highest accuracy at reasonable RF power deposition both at 4 T and 7 T. The various polarization transfer methods all have comparable performances, but may become infeasible at 7 T due to the high RF power deposition. 2D MR methods have limited value for the metabolites considered (primarily glutamate, glutamine and γ-amino butyric acid (GABA)), but may prove valuable when additional information can be extracted, such as isotopomers or lipid composition. While providing the lowest accuracy, the detection of non-protonated carbons is the simplest to implement with the lowest RF power deposition. The magnetic field homogeneity is one of the most important parameters affecting the detection accuracy for all metabolites and all acquisition methods.

  14. Real time quantitative colourimetric test for methamphetamine detection using digital and mobile phone technology.

    PubMed

    Choodum, Aree; Parabun, Kaewalee; Klawach, Nantikan; Daeid, Niamh Nic; Kanatharana, Proespichaya; Wongniramaikul, Worawit

    2014-02-01

    The Simon presumptive color test was used in combination with the built-in digital camera on a mobile phone to detect methamphetamine. The real-time Red-Green-Blue (RGB) basic color data was obtained using an application installed on the mobile phone and the relationship profile between RGB intensity, including other calculated values, and the colourimetric product was investigated. A wide linear range (0.1-2.5mg mL(-1)) and a low detection limit (0.0110±0.0001-0.044±0.002mg mL(-1)) were achieved. The method also required a small sample size (20μL). The results obtained from the analysis of illicit methamphetamine tablets were comparable to values obtained from gas chromatograph-flame ionization detector (GC-FID) analysis. Method validation indicated good intra- and inter-day precision (2.27-4.49%RSD and 2.65-5.62%RSD, respectively). The results suggest that this is a powerful real-time mobile method with the potential to be applied in field tests. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  15. Collaborative ring trial of the papaya endogenous reference gene and its polymerase chain reaction assays for genetically modified organism analysis.

    PubMed

    Wei, Jiaojun; Li, Feiwu; Guo, Jinchao; Li, Xiang; Xu, Junfeng; Wu, Gang; Zhang, Dabing; Yang, Litao

    2013-11-27

    The papaya (Carica papaya L.) Chymopapain (CHY) gene has been reported as a suitable endogenous reference gene for genetically modified (GM) papaya detection in previous studies. Herein, we further validated the use of the CHY gene and its qualitative and quantitative polymerase chain reaction (PCR) assays through an interlaboratory collaborative ring trial. A total of 12 laboratories working on detection of genetically modified organisms participated in the ring trial and returned test results. Statistical analysis of the returned results confirmed the species specificity, low heterogeneity, and single-copy number of the CHY gene among different papaya varieties. The limit of detection of the CHY qualitative PCR assay was 0.1%, while the limit of quantification of the quantitative PCR assay was ∼25 copies of haploid papaya genome with acceptable PCR efficiency and linearity. The differences between the tested and true values of papaya content in 10 blind samples ranged from 0.84 to 6.58%. These results indicated that the CHY gene was suitable as an endogenous reference gene for the identification and quantification of GM papaya.

  16. Development and validation of an universal interface for compound-specific stable isotope analysis of chlorine (37Cl/35Cl) by GC-high-temperature conversion (HTC)-MS/IRMS.

    PubMed

    Renpenning, Julian; Hitzfeld, Kristina L; Gilevska, Tetyana; Nijenhuis, Ivonne; Gehre, Matthias; Richnow, Hans-Hermann

    2015-03-03

    A universal application of compound-specific isotope analysis of chlorine was thus far limited by the availability of suitable analysis techniques. In this study, gas chromatography in combination with a high-temperature conversion interface (GC-HTC), converting organic chlorine in the presence of H2 to gaseous HCl, was coupled to a dual-detection system, combining an ion trap mass spectrometer (MS) and isotope-ratio mass spectrometer (IRMS). The combination of the MS/IRMS detection enabled a detailed characterization, optimization, and online monitoring of the high-temperature conversion process via ion trap MS as well as a simultaneous chlorine isotope analysis by the IRMS. Using GC-HTC-MS/IRMS, chlorine isotope analysis at optimized conversion conditions resulted in very accurate isotope values (δ(37)Cl(SMOC)) for measured reference material with known isotope composition, including chlorinated ethylene, chloromethane, hexachlorocyclohexane, and trichloroacetic acids methyl ester. Respective detection limits were determined to be <15 nmol Cl on column with achieved precision of <0.3‰.

  17. Automation of sample processing for ICP-MS determination of 90Sr radionuclide at ppq level for nuclear technology and environmental purposes.

    PubMed

    Kołacińska, Kamila; Chajduk, Ewelina; Dudek, Jakub; Samczyński, Zbigniew; Łokas, Edyta; Bojanowska-Czajka, Anna; Trojanowicz, Marek

    2017-07-01

    90 Sr is a widely determined radionuclide for environmental purposes, nuclear waste control, and can be also monitored in coolants in nuclear reactor plants. In the developed method, the ICP-MS detection was employed together with sample processing in sequential injection analysis (SIA) setup, equipped with a lab-on-valve with mechanized renewal of sorbent bed for solid-phase extraction. The optimized conditions of determination included preconcentration of 90 Sr on cation-exchange column and removal of different type of interferences using extraction Sr-resin. The limit of detection of the developed procedure depends essentially on the configuration of the employed ICP-MS spectrometer and on the available volume of the sample to be analyzed. For 1L initial sample volume, the method detection limit (MDL) value was evaluated as 2.9ppq (14.5BqL -1 ). The developed method was applied to analyze spiked river water samples, water reference materials, and also simulated and real samples of the nuclear reactor coolant. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Perirectal Swab Surveillance for Clostridium difficile by Use of Selective Broth Preamplification and Real-Time PCR Detection of tcdB ▿

    PubMed Central

    Curry, Scott R.; Schlackman, Jessica L.; Hamilton, Travis M.; Henderson, Tatianna K.; Brown, Nakita T.; Marsh, Jane W.; Shutt, Kathleen A.; Brooks, Maria M.; Pasculle, A. William; Muto, Carlene A.; Harrison, Lee H.

    2011-01-01

    Active surveillance testing to identify and isolate asymptomatic carriers of toxigenic Clostridium difficile has been limited by the lack of a test that is sensitive, specific, and timely enough to serve as an infection control tool. We tested DNA preamplified from perirectal surveillance specimens in a liquid medium selective for C. difficile by using a modified commercial real-time PCR assay. All fermenting specimens were subcultured, and isolates were tested for toxigenicity. Culture-positive toxigenic isolates served as the gold standard for comparison with the broth preamplification/PCR assay. The limit of detection for the assay was 1 CFU. Relative to toxigenic anaerobic culture, the sensitivity, specificity, and positive and negative predictive values of this assay were 70/70 (100.0%), 422/426 (99.1%), 70/74 (94.6%), and 422/422 (100.0%), respectively. These data demonstrate that selective broth preamplification and real-time PCR of perirectal swab specimens constitute a practical approach to the detection of asymptomatic C. difficile carriage. PMID:21880961

  19. High-performance gas sensors with temperature measurement

    PubMed Central

    Zhang, Yong; Li, Shengtao; Zhang, Jingyuan; Pan, Zhigang; Min, Daomin; Li, Xin; Song, Xiaoping; Liu, Junhua

    2013-01-01

    There are a number of gas ionization sensors using carbon nanotubes as cathode or anode. Unfortunately, their applications are greatly limited by their multi-valued sensitivity, one output value corresponding to several measured concentration values. Here we describe a triple-electrode structure featuring two electric fields with opposite directions, which enable us to overcome the multi-valued sensitivity problem at 1 atm in a wide range of gas concentrations. We used a carbon nanotube array as the first electrode, and the two electric fields between the upper and the lower interelectrode gaps were designed to extract positive ions generated in the upper gap, hence significantly reduced positive ion bombardment on the nanotube electrode, which allowed us to maintain a high electric field near the nanotube tips, leading to a single-valued sensitivity and a long nanotube life. We have demonstrated detection of various gases and simultaneously monitoring temperature, and a potential for applications. PMID:23405281

  20. On-line solid-phase microextraction of triclosan, bisphenol A, chlorophenols, and selected pharmaceuticals in environmental water samples by high-performance liquid chromatography-ultraviolet detection.

    PubMed

    Kim, Dalho; Han, Jungho; Choi, Yongwook

    2013-01-01

    A method using on-line solid-phase microextraction (SPME) on a carbowax-templated fiber followed by liquid chromatography (LC) with ultraviolet (UV) detection was developed for the determination of triclosan in environmental water samples. Along with triclosan, other selected phenolic compounds, bisphenol A, and acidic pharmaceuticals were studied. Previous SPME/LC or stir-bar sorptive extraction/LC-UV for polar analytes showed lack of sensitivity. In this study, the calculated octanol-water distribution coefficient (log D) values of the target analytes at different pH values were used to estimate polarity of the analytes. The lack of sensitivity observed in earlier studies is identified as a lack of desorption by strong polar-polar interactions between analyte and solid-phase. Calculated log D values were useful to understand or predict the interaction between analyte and solid phase. Under the optimized conditions, the method detection limit of selected analytes by using on-line SPME-LC-UV method ranged from 5 to 33 ng L(-1), except for very polar 3-chlorophenol and 2,4-dichlorophenol which was obscured in wastewater samples by an interfering substance. This level of detection represented a remarkable improvement over the conventional existing methods. The on-line SPME-LC-UV method, which did not require derivatization of analytes, was applied to the determination of TCS including phenolic compounds and acidic pharmaceuticals in tap water and river water and municipal wastewater samples.

  1. Orbital Signature Analyzer (OSA): A spacecraft health/safety monitoring and analysis tool

    NASA Technical Reports Server (NTRS)

    Weaver, Steven; Degeorges, Charles; Bush, Joy; Shendock, Robert; Mandl, Daniel

    1993-01-01

    Fixed or static limit sensing is employed in control centers to ensure that spacecraft parameters remain within a nominal range. However, many critical parameters, such as power system telemetry, are time-varying and, as such, their 'nominal' range is necessarily time-varying as well. Predicted data, manual limits checking, and widened limit-checking ranges are often employed in an attempt to monitor these parameters without generating excessive limits violations. Generating predicted data and manual limits checking are both resource intensive, while broadening limit ranges for time-varying parameters is clearly inadequate to detect all but catastrophic problems. OSA provides a low-cost solution by using analytically selected data as a reference upon which to base its limits. These limits are always defined relative to the time-varying reference data, rather than as fixed upper and lower limits. In effect, OSA provides individual limits tailored to each value throughout all the data. A side benefit of using relative limits is that they automatically adjust to new reference data. In addition, OSA provides a wealth of analytical by-products in its execution.

  2. Tolerance of image enhancement brightness and contrast in lateral cephalometric digital radiography for Steiner analysis

    NASA Astrophysics Data System (ADS)

    Rianti, R. A.; Priaminiarti, M.; Syahraini, S. I.

    2017-08-01

    Image enhancement brightness and contrast can be adjusted on lateral cephalometric digital radiographs to improve image quality and anatomic landmarks for measurement by Steiner analysis. To determine the limit value for adjustments of image enhancement brightness and contrast in lateral cephalometric digital radiography for Steiner analysis. Image enhancement brightness and contrast were adjusted on 100 lateral cephalometric radiography in 10-point increments (-30, -20, -10, 0, +10, +20, +30). Steiner analysis measurements were then performed by two observers. Reliabilities were tested by the Interclass Correlation Coefficient (ICC) and significance tested by ANOVA or the Kruskal Wallis test. No significant differences were detected in lateral cephalometric analysis measurements following adjustment of the image enhancement brightness and contrast. The limit value of adjustments of the image enhancement brightness and contrast associated with incremental 10-point changes (-30, -20, -10, 0, +10, +20, +30) does not affect the results of Steiner analysis.

  3. Comparison of two methods for detection of strain localization in sheet forming

    NASA Astrophysics Data System (ADS)

    Lumelskyj, Dmytro; Lazarescu, Lucian; Banabic, Dorel; Rojek, Jerzy

    2018-05-01

    This paper presents a comparison of two criteria of strain localization in experimental research and numerical simulation of sheet metal forming. The first criterion is based on the analysis of the through-thickness thinning (through-thickness strain) and its first time derivative in the most strained zone. The limit strain in the second method is determined by the maximum of the strain acceleration. Experimental and numerical investigation have been carried out for the Nakajima test performed for different specimens of the DC04 grade steel sheet. The strain localization has been identified by analysis of experimental and numerical curves showing the evolution of strains and their derivatives in failure zones. The numerical and experimental limit strains calculated from both criteria have been compared with the experimental FLC evaluated according to the ISO 12004-2 norm. It has been shown that the first method predicts formability limits closer to the experimental FLC. The second criterion predicts values of strains higher than FLC determined according to ISO norm. These values are closer to the strains corresponding to the fracture limit. The results show that analysis of strain evolution allows us to determine strain localization in numerical simulation and experimental studies.

  4. Diagnosis of toxic alcohols: limitations of present methods.

    PubMed

    Kraut, Jeffrey A

    2015-01-01

    Methanol, ethylene glycol, diethylene glycol, and propylene glycol intoxications are associated with cellular dysfunction and an increased risk of death. Adverse effects can develop quickly; thus, there is a need for methods for rapidly detecting their presence. To examine the value and limitations of present methods to diagnose patients with possible toxic alcohol exposure. I searched MEDLINE for articles published between 1969 and 2014 using the terms: toxic alcohols, serum osmolality, serum osmol gap, serum anion gap, metabolic acidosis, methanol, ethylene glycol, diethylene glycol, propylene glycol, and fomepizole. Each article was reviewed for additional references. The diagnosis of toxic alcohol exposure is often made on the basis of this history and physical findings along with an increase in the serum osmol and anion gaps. However, an increase in the osmol and/or anion gaps is not always present. Definitive detection in blood requires gas or liquid chromatography, laborious and expensive procedures which are not always available. Newer methods including a qualitative colorimetric test for detection of all alcohols or enzymatic tests for a specific alcohol might allow for more rapid diagnosis. Exposure to toxic alcohols is associated with cellular dysfunction and increased risk of death. Treatment, if initiated early, can markedly improve outcome, but present methods of diagnosis including changes in serum osmol and anion gap, and use of gas or liquid chromatography have important limitations. Development of more rapid and effective tests for detection of these intoxications is essential for optimal care of patients.

  5. Predicting genotypes environmental range from genome-environment associations.

    PubMed

    Manel, Stéphanie; Andrello, Marco; Henry, Karine; Verdelet, Daphné; Darracq, Aude; Guerin, Pierre-Edouard; Desprez, Bruno; Devaux, Pierre

    2018-05-17

    Genome-environment association methods aim to detect genetic markers associated with environmental variables. The detected associations are usually analysed separately to identify the genomic regions involved in local adaptation. However, a recent study suggests that single-locus associations can be combined and used in a predictive way to estimate environmental variables for new individuals on the basis of their genotypes. Here, we introduce an original approach to predict the environmental range (values and upper and lower limits) of species genotypes from the genetic markers significantly associated with those environmental variables in an independent set of individuals. We illustrate this approach to predict aridity in a database constituted of 950 individuals of wild beets and 299 individuals of cultivated beets genotyped at 14,409 random Single Nucleotide Polymorphisms (SNPs). We detected 66 alleles associated with aridity and used them to calculate the fraction (I) of aridity-associated alleles in each individual. The fraction I correctly predicted the values of aridity in an independent validation set of wild individuals and was then used to predict aridity in the 299 cultivated individuals. Wild individuals had higher median values and a wider range of values of aridity than the cultivated individuals, suggesting that wild individuals have higher ability to resist to stress-aridity conditions and could be used to improve the resistance of cultivated varieties to aridity. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  6. Diagnostic performance of influenza viruses and RSV rapid antigen detection tests in children in tertiary care.

    PubMed

    Moesker, F M; van Kampen, J J A; Aron, G; Schutten, M; van de Vijver, D A M C; Koopmans, M P G; Osterhaus, A D M E; Fraaij, P L A

    2016-06-01

    Rapid antigen detection tests (RADTs) are increasingly used to detect influenza viruses and respiratory syncytial virus (RSV). However, their sensitivity and specificity are a matter of debate, challenging their clinical usefulness. Comparing diagnostic performances of BinaxNow Influenza AB(®) (BNI) and BinaxNow RSV(®) (BNR), to those of real-time reverse transcriptase PCR (RT-PCR), virus isolation and direct immunofluorescence (D-IF) in paediatric patients. Between November 2005 and September 2013, 521 nasal washings from symptomatic children (age <5 years) attending our tertiary care centre were tested, with a combination of the respective assays using RT-PCR as gold standard. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of BNI were 69% (confidence interval [CI] [51-83]), 96% [94-97], 55% [39-70] and 98% [96-99] respectively. Of eleven false-negative samples, RT-PCR Ct-values were higher than all RT-PCR positive test results (27 vs 22, p=0.012). Of twenty false-positive samples, none were culture positive and two tested positive in D-IF. Sensitivity, specificity, PPV and NPV for BNR were 79% [73-85], 98% [96-99], 97% [93-99] and 88% [84-91]. Of the 42 false-negative samples the median Ct-value was higher than that of all RT-PCR positive samples (31 vs 23, p<0.0001). Five false-positive samples were detected. Three of these tested positive for RSV in virus isolation and D-IF. RADTs have a high specificity with BNR being superior to BNI. However, their relative low sensitivity limits their usefulness for clinical decision making in a tertiary care paediatric hospital. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  7. Regional monitoring activities, June 1958

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Andersen, B.V.

    1958-07-17

    The Klamath Falls measurements indicated old fallout materials were present on the vegetation. Cs{sup 137} on Zone B vegetation (200 East Area) averaged 4.1 {times} 10{sup -6} {mu}c/gm this month, compared to an average of 4.4 {times} 10{sup -6} {mu}c/gm last month. Other special measurements this month included calculation of reactor effluent water originated radioisotopes present in samples of Zone Z (Franklin County Irrigation District) vegetation analyzed by gamma spectroscopy. Monthly average values were below the detection limit of about 2 {times} 10{sup -6} {mu}c/gm for Zn{sup 65} and Cr{sup 57}. Maximum Zn{sup 65} concentration was 1.7 {times} 10{sup -6}more » {mu}c/gm on samples collected May 28, 1958. Crop samples of strawberries, green beans, apricots, and potatoes from the Franklin County Irrigation District were taken during June. Analytical results are not yet available. Analytical detection limits for isotopes expected in crop samples were requested at 1/500 of the public limit for human intake of the isotopes.« less

  8. Analytical and sampling constraints in ²¹⁰Pb dating.

    PubMed

    MacKenzie, A B; Hardie, S M L; Farmer, J G; Eades, L J; Pulford, I D

    2011-03-01

    ²¹⁰Pb dating provides a valuable, widely used means of establishing recent chronologies for sediments and other accumulating natural deposits. The Constant Rate of Supply (CRS) model is the most versatile and widely used method for establishing ²¹⁰Pb chronologies but, when using this model, care must be taken to account for limitations imposed by sampling and analytical factors. In particular, incompatibility of finite values for empirical data, which are constrained by detection limit and core length, with terms in the age calculation, which represent integrations to infinity, can generate erroneously old ages for deeper sections of cores. The bias in calculated ages increases with poorer limit of detection and the magnitude of the disparity increases with age. The origin and magnitude of this effect are considered below, firstly for an idealized, theoretical ²¹⁰Pb profile and secondly for a freshwater lake sediment core. A brief consideration is presented of the implications of this potential artefact for sampling and analysis. Copyright © 2011 Elsevier B.V. All rights reserved.

  9. Development of phage/antibody immobilized magnetostrictive biosensors

    NASA Astrophysics Data System (ADS)

    Fu, Liling

    There is an urgent need for biosensors that are able to detect and quantify the presence of a small amount of pathogens in a real-time manner accurately and quickly to guide prevention efforts and assay food and water quality. Acoustic wave (AW) devices, whose performance is defined by mass sensitivity (Sm) and quality factor (Q value), have been extensively studied as high performance biosensor platforms. However, current AW devices still face some challenges such as the difficulty to be employed in liquid and low Q value in practical applications. The objective of this research is to develop magnetostrictive sensors which include milli/microcantilever type (MSMC) and particle type (MSP). Compared to other AW devices, MSMC exhibits the following advantages: (1) wireless/remote driving and sensing; (2) easy to fabricate; (3) works well in liquid; (4) exhibits a high Q value (> 500 in air). The fundamental study of the damping effect on MSMCs from the surrounding media including air and liquids were conducted to improve the Q value of MSMCs. The experiment results show that the Q value is dependent on the properties of surrounding media (e.g. viscosity, density), the geometry of the MSMCs, and the harmonic mode on the resonance behavior of MSMCs, etc. The phage-coated MSMC has high specificity and sensitivity even while used in water with a low concentration of targeted bacteria. Two currently developed phages, JRB7 and E2, respectively respond to Bacillus anthracis spores and Salmonella typhimurium, were employed as bio-recognition elements in this research. The phage-immobilized MSMC biosensors exhibited high performance and detection of limit was 5 x 104 cfu/ml for the MSMC in size of 1.4 x 0.8 x 0.035 mm. The MSMC-based biosensors were indicated as a very potential method for in-situ monitoring of the biological quality in water. The MSP combine antibody was used to detect Staphylococcus aureus in this experiment. The interface between MSPs and antibody was modified using Traut's Reagent by introducing the sulfhydryl group. To improve the mass sensitivity of magnetostrictive biosensors, several blocking agents were used to resist the nonspecific adsorption of S. aureus on the surface of the magnetostrictive biosensors and the blocking effects were studied by using ELISA and SEM. The results showed casein was one of the best blocking agents to resist the nonspecific binding in this experiment. Casein blocked antibody immobilized MSP biosensors exhibited high sensitivity and the limit of detection is 102 cfu/ml.

  10. DNA Microarray Detection of 18 Important Human Blood Protozoan Species

    PubMed Central

    Chen, Jun-Hu; Feng, Xin-Yu; Chen, Shao-Hong; Cai, Yu-Chun; Lu, Yan; Zhou, Xiao-Nong; Chen, Jia-Xu; Hu, Wei

    2016-01-01

    Background Accurate detection of blood protozoa from clinical samples is important for diagnosis, treatment and control of related diseases. In this preliminary study, a novel DNA microarray system was assessed for the detection of Plasmodium, Leishmania, Trypanosoma, Toxoplasma gondii and Babesia in humans, animals, and vectors, in comparison with microscopy and PCR data. Developing a rapid, simple, and convenient detection method for protozoan detection is an urgent need. Methodology/Principal Findings The microarray assay simultaneously identified 18 species of common blood protozoa based on the differences in respective target genes. A total of 20 specific primer pairs and 107 microarray probes were selected according to conserved regions which were designed to identify 18 species in 5 blood protozoan genera. The positive detection rate of the microarray assay was 91.78% (402/438). Sensitivity and specificity for blood protozoan detection ranged from 82.4% (95%CI: 65.9% ~ 98.8%) to 100.0% and 95.1% (95%CI: 93.2% ~ 97.0%) to 100.0%, respectively. Positive predictive value (PPV) and negative predictive value (NPV) ranged from 20.0% (95%CI: 2.5% ~ 37.5%) to 100.0% and 96.8% (95%CI: 95.0% ~ 98.6%) to 100.0%, respectively. Youden index varied from 0.82 to 0.98. The detection limit of the DNA microarrays ranged from 200 to 500 copies/reaction, similar to PCR findings. The concordance rate between microarray data and DNA sequencing results was 100%. Conclusions/Significance Overall, the newly developed microarray platform provides a convenient, highly accurate, and reliable clinical assay for the determination of blood protozoan species. PMID:27911895

  11. Nonlethal evaluation of the physiological health of unionid mussels: Method for biopsy and glycogen analysis

    USGS Publications Warehouse

    Naimo, T.J.; Damschen, E.D.; Rada, R.G.; Monroe, E.M.

    1998-01-01

    In long-lived unionid mussels, many short-term measures of growth are of limited value. Changes in physiological condition may be an early indication of stress, because the increased energy demand associated with stress often results in a depletion of glycogen reserves, the principal storage form of carbohydrates in unionid mussels. Our goal was to nonlethally extract tissue from freshwater mussels and then to develop a rapid and dependable method for the analysis of glycogen in the tissue extracts. A biopsy technique was developed to remove between 5 and 10 mg of food tissue in Amblema plicata plicata. The survival rate did not differ between biopsied and non-biopsied mussels during a 581-d observation period, demonstrating that the biopsy technique will allow nonlethal evaluation of the physiological condition of individual mussels through measurement of changes in contaminant, genetic, and biochemical indicators in tissue. We also modified the standard alkaline digestion and phenol-sulfuric acid analysis of glycogen for use on the small samples of biopsied tissue and to reduce analysis time and cost. We present quality control data, including method detection limits and estimates of precision and bias. The modified analytical method is rapid and accurate and has a method detection limit of 0.014 mg glycogen. Glycogen content in the biopsied samples was well above the method detection limit; it ranged from 0.09 to 0.36 mg, indicating that the method should be applicable to native mussels.

  12. Clinical impact of the lower limit of normal of FEV1/FVC on detecting chronic obstructive pulmonary disease: A follow-up study based on cross-sectional data.

    PubMed

    Liu, Sha; Zhou, Yumin; Liu, Shiliang; Zou, Weifeng; Li, Xiaochen; Li, Chenglong; Deng, Zhishan; Zheng, Jinzhen; Li, Bing; Ran, Pixin

    2018-06-01

    Criteria of obstruction that establish a diagnosis of COPD have been debated in recent years. We carried out a follow-up study to assess the impact of the new LLN reference equation for Chinese on detecting COPD compared with the traditional 0.7fixed criteria. We examined the prevalence and characteristics of airflow limitation for a non-child population using post-bronchodilator airflow with both age-dependent predicted lower limit of the normal value and fixed-ratio spirometric criterion. Questionnaires and spirometry were completed for all eligible subjects during the baseline examination. Participants with inconsistent diagnosis according to the two criteria, normal participants (controls) and COPD patients in stages I or II, were invited to take a cardiopulmonary exercise testing (CPET) examination and follow up for 2-4 years. A total of 5448 (mean age 50.51 ± 13.2 yr) study subjects with acceptable spirometry and complete questionnaire data were included in our final analyses. COPD detection based on LLN was consistent with the GOLD 0.7 fixed-ratio in general, as 51 subjects (0.9%) were underdiagnosed, and 61 subjects (1.1%) were overdiagnosed when using LLN as the reference diagnostic criterion. The underdiagnosed subjects were younger, had more symptoms, more exposure to biofuels and worse FEV 1 than the normal group; they also demonstrated a damaged cardiopulmonary reserve capacity and significant FEV 1 decline. Except for being older, the overdiagnosed subjects differed little from the normal group. Individual-dependent LLN appears to better reveal impacts on detecting airflow limitation. Participants underdiagnosed by GOLD criterion should be paid more attention. ChiCTR-ECS-13004110. Copyright © 2018 Elsevier Ltd. All rights reserved.

  13. Automated control of linear constricted plasma source array

    DOEpatents

    Anders, Andre; Maschwitz, Peter A.

    2000-01-01

    An apparatus and method for controlling an array of constricted glow discharge chambers are disclosed. More particularly a linear array of constricted glow plasma sources whose polarity and geometry are set so that the contamination and energy of the ions discharged from the sources are minimized. The several sources can be mounted in parallel and in series to provide a sustained ultra low source of ions in a plasma with contamination below practical detection limits. The quality of film along deposition "tracks" opposite the plasma sources can be measured and compared to desired absolute or relative values by optical and/or electrical sensors. Plasma quality can then be adjusted by adjusting the power current values, gas feed pressure/flow, gas mixtures or a combination of some or all of these to improve the match between the measured values and the desired values.

  14. Determination of sulfonamide antibiotics and metabolites in liver, muscle and kidney samples by pressurized liquid extraction or ultrasound-assisted extraction followed by liquid chromatography-quadrupole linear ion trap-tandem mass spectrometry (HPLC-QqLIT-MS/MS).

    PubMed

    Hoff, Rodrigo Barcellos; Pizzolato, Tânia Mara; Peralba, Maria do Carmo Ruaro; Díaz-Cruz, M Silvia; Barceló, Damià

    2015-03-01

    Sulfonamides are widely used in human and veterinary medicine. The presence of sulfonamides residues in food is an issue of great concern. Throughout the present work, a method for the targeted analysis of 16 sulfonamides and metabolites residue in liver of several species has been developed and validated. Extraction and clean-up has been statistically optimized using central composite design experiments. Two extraction methods have been developed, validated and compared: i) pressurized liquid extraction, in which samples were defatted with hexane and subsequently extracted with acetonitrile and ii) ultrasound-assisted extraction with acetonitrile and further liquid-liquid extraction with hexane. Extracts have been analyzed by liquid chromatography-quadrupole linear ion trap-tandem mass spectrometry. Validation procedure has been based on the Commission Decision 2002/657/EC and included the assessment of parameters such as decision limit (CCα), detection capability (CCβ), sensitivity, selectivity, accuracy and precision. Method׳s performance has been satisfactory, with CCα values within the range of 111.2-161.4 µg kg(-1), limits of detection of 10 µg kg(-1) and accuracy values around 100% for all compounds. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. An iPhone-based digital image colorimeter for detecting tetracycline in milk.

    PubMed

    Masawat, Prinya; Harfield, Antony; Namwong, Anan

    2015-10-01

    An iPhone-based digital image colorimeter (DIC) was fabricated as a portable tool for monitoring tetracycline (TC) in bovine milk. An application named ColorConc was developed for the iPhone that utilizes an image matching algorithm to determine the TC concentration in a solution. The color values; red (R), green (G), blue (B), hue (H), saturation (S), brightness (V), and gray (Gr) were measured from each pictures of the TC standard solutions. TC solution extracted from milk samples using solid phase extraction (SPE) was captured and the concentration was predicted by comparing color values with those collected in a database. The amount of TC could be determined in the concentration range of 0.5-10 μg mL(-1). The proposed DIC-iPhone is able to provide a limit of detection (LOD) of 0.5 μg mL(-1) and limit of quantitation (LOQ) of 1.5 μg mL(-1). The enrichment factor was 70 and color of the extracted milk sample was a strong yellow solution after SPE. Therefore, the SPE-DIC-iPhone could be used for the assay of TC residues in milk at the concentration lower than LOD and LOQ of the proposed technique. Copyright © 2015 Elsevier Ltd. All rights reserved.

  16. Application of an ETV-ICP system for the determination of elements in human hair*1

    NASA Astrophysics Data System (ADS)

    Plantikow-Voβgätter, F.; Denkhaus, E.

    1996-01-01

    When determining element contents in hair samples without sample digestion it is necessary to analyze large sample volumes in order to minimize problems of inhomogeneity of biological sample materials. Therefore an electrothermal vaporization system (ETV) is used for solid sample introduction into an inductively coupled plasma (ICP) for the determination of matrix and trace elements in hair. This paper concentrates on the instrumental aspects without time consuming sample preparation. The results obtained for optimization tests, ETV operating parameters and ICP operating parameters, are shown and discussed. Standard additions are used for calibration for the determination of Zn, Mg, and Mn in human hair. Studies including reproducibility and detection limits for chosen elements have been carried out on certified reference materials (CRMs). The determination of reproducibility (relative standard deviation (RSD) of n = 10) and detection limits (DLs) of Zn (RSD < 8.5%, DL < 0.8 μ g -1), Mn (RSD < 14.1%, DL < 0.3 μ g -1), and Mg (RSD < 7.4%, DL < 6.6 μ g -1) are satisfactory. The concentration values found show good agreement with the corresponding certified values. Further sample preparation steps, including hair sampling, washing procedure and homogenization for hair, relating to measurements of real hair samples are described.

  17. Indoor radiocaesium contamination in residential houses within evacuation areas after the Fukushima nuclear accident

    PubMed Central

    Yoshida-Ohuchi, Hiroko; Kanagami, Takashi; Satoh, Yasushi; Hosoda, Masahiro; Naitoh, Yutaka; Kameyama, Mizuki

    2016-01-01

    Indoor contaminants were investigated from July 2013 to January 2015 within ninety-five residential houses in five evacuation zones, Iitate village, Odaka district, and the towns of Futaba, Okuma, and Tomioka. A dry smear test was applied to the surface of materials and structures in rooms and in the roof-space of houses. We found that 134Cs and 137Cs were the dominant radionuclides in indoor surface contamination, and there was a distance dependence from the Fukushima Daiichi nuclear power plant (FDNPP). For surface contamination in Iitate village (29–49 km from the FDNPP), 24.8% of samples exceeded the detection limit, which is quite a low value, while in Okuma (<3.0 km from the FDNPP), 99.7% of samples exceeded the detection limit and surface contamination levels exceeded 20 Bq/cm2 (the value was corrected to March 2011). In residential houses in Okuma, Futaba, and Tomioka, closer to the FDNPP than those in Odaka district and Iitate village, surface contamination was inversely proportional to the square of the distance between a house and the FDNPP. In the houses closest to the FDNPP, the contribution of surface contamination to the ambient dose equivalent rate was evaluated to be approximately 0.3 μSv/h. PMID:27212076

  18. Extraction of polycyclic aromatic hydrocarbons and organochlorine pesticides from soils: a comparison between Soxhlet extraction, microwave-assisted extraction and accelerated solvent extraction techniques.

    PubMed

    Wang, Wentao; Meng, Bingjun; Lu, Xiaoxia; Liu, Yu; Tao, Shu

    2007-10-29

    The methods of simultaneous extraction of polycyclic aromatic hydrocarbons (PAHs) and organochlorine pesticides (OCPs) from soils using Soxhlet extraction, microwave-assisted extraction (MAE) and accelerated solvent extraction (ASE) were established, and the extraction efficiencies using the three methods were systemically compared from procedural blank, limits of detection and quantification, method recovery and reproducibility, method chromatogram and other factors. In addition, soils with different total organic carbon contents were used to test the extraction efficiencies of the three methods. The results showed that the values obtained in this study were comparable with the values reported by other studies. In some respects such as method recovery and reproducibility, there were no significant differences among the three methods for the extraction of PAHs and OCPs. In some respects such as procedural blank and limits of detection and quantification, there were significant differences among the three methods. Overall, ASE had the best extraction efficiency compared to MAE and Soxhlet extraction, and the extraction efficiencies of MAE and Soxhlet extraction were comparable to each other depending on the property such as TOC content of the studied soil. Considering other factors such as solvent consumption and extraction time, ASE and MAE are preferable to Soxhlet extraction.

  19. A study of the influence on diabetes of free and conjugated bisphenol A concentrations in urine: Development of a simple microextraction procedure using gas chromatography-mass spectrometry.

    PubMed

    Pastor-Belda, Marta; Bastida, David; Campillo, Natalia; Pérez-Cárceles, María D; Motas, Miguel; Viñas, Pilar

    2016-09-10

    The association between bisphenol A (BPA) exposure and adult health status is examined by measuring the urinary BPA concentration using a miniaturized technique based on dispersive liquid-liquid microextraction (DLLME) in combination with gas chromatography-mass spectrometry (GC-MS). Both the free bioactive and the glucuronide conjugated forms of BPA were measured, the glucuronide form usually being predominant. The main analogs of BPA, including bisphenol Z (BPZ), bisphenol F (BPF) and biphenol (BP) were also determined. Several parameters affecting enzymatic hydrolysis, derivatization by in-situ acetylation and the DLLME stages were carefully optimized by means of multivariate designs. DLLME parameters were 2mL urine, 1mL acetone and 100μL chloroform, and hydrolysis was performed using β-glucuronidase and sulfatase at pH 5. No matrix effect was observed and quantification was carried out by aqueous calibration with a surrogate standard. Detection limits were in the range 0.01-0.04ngmL(-1). The intraday and interday precisions were lower than 11% in terms of relative standard deviation. Satisfactory values for all compounds were obtained in recovery studies (92-117%) at two concentration levels. Other bisphenols (BPF, BPZ and BP) were not detected in the urine samples, while BPA was the only bisphenol detected in the free form (creatinine adjusted) at concentration levels ranging from the detection limit to 15.9ngg(-1), and total BPA was detected at concentrations ranging from 0.46 to 24.5ngg(-1) levels. A comparison of the BPA content for both groups of patients revealed that slightly higher mean values were obtained for both free BPA and total BPA for diabetic patients, than for non-diabetic patients. However, a statistical comparison of the contents of BPA revealed that there were no significant differences. The procedure was validated using a certified reference material. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Leaky electronic states for photovoltaic photodetectors based on asymmetric superlattices

    NASA Astrophysics Data System (ADS)

    Penello, Germano Maioli; Pereira, Pedro Henrique; Pires, Mauricio Pamplona; Sivco, Deborah; Gmachl, Claire; Souza, Patricia Lustoza

    2018-01-01

    The concept of leaky electronic states in the continuum is used to achieve room temperature operation of photovoltaic superlattice infrared photodetectors. A structural asymmetric InGaAs/InAlAs potential profile is designed to create states in the continuum with the preferential direction for electron extraction and, consequently, to obtain photovoltaic operation at room temperature. Due to the photovoltaic operation and virtual increase in the bandoffset, the device presents both low dark current and low noise. The Johnson noise limited specific detectivity reaches values as high as 1.4 × 1011 Jones at 80 K. At 300 K, the detectivity obtained is 7.0 × 105 Jones.

  1. Fluorenone based fluorescent probe for selective "turn-on" detection of pyrophosphate and alanine

    NASA Astrophysics Data System (ADS)

    Daniel Thangadurai, T.; Nithya, I.; Manjubaashini, N.; Bhuvanesh, N.; Bharathi, G.; Nandhakumar, R.; Nataraj, D.

    2018-06-01

    To sense biologically important entities with different size and dimensions, a fluorenone based fluorescent receptor was designed and synthesized. Probe 1 displayed a distinct fluorescence enhancement emission at 565 nm for pyrophosphate and 530 nm for alanine in polar solvent. The fluorescence titration experiments confirm 1:1 stoichiometric ratio with high-binding constant and very low limit of detection (LoD) values. Receptor 1 showed a highly selective and sensitive recognition to HP2O73 - and to alanine over other competitive anions and amino acids. In addition, the fluorescence lifetime measurement and reversible binding study results support the practical importance of 1.

  2. [The determination of the herbicide glyphosate and its chief metabolite aminomethylphosphonic acid (AMPA) in drinking water with the aid of HPLC].

    PubMed

    Gauch, R; Leuenberger, U; Müller, U

    1989-01-01

    A method for the determination of glyphosate and its major metabolite aminomethylphosphonic acid (AMPA) is described. With a detection limit of 0.02 microgram/l, the method suitably fulfills the requirements of the Swiss legislation (tolerance value of 0.1 micrograms/l water). The compounds are derivatized directly in the original water sample with 9-fluorenylmethyl chloroformate (FMOCC1) in order to obtain extractable and fluorescent derivatives. These are extracted with organic solvents and determined by HPLC using a fluorescence detector. Neither of the compounds could be detected in 151 tap water samples from the Canton of Berne.

  3. Non-Markovian stochastic Schrödinger equations: Generalization to real-valued noise using quantum-measurement theory

    NASA Astrophysics Data System (ADS)

    Gambetta, Jay; Wiseman, H. M.

    2002-07-01

    Do stochastic Schrödinger equations, also known as unravelings, have a physical interpretation? In the Markovian limit, where the system on average obeys a master equation, the answer is yes. Markovian stochastic Schrödinger equations generate quantum trajectories for the system state conditioned on continuously monitoring the bath. For a given master equation, there are many different unravelings, corresponding to different sorts of measurement on the bath. In this paper we address the non-Markovian case, and in particular the sort of stochastic Schrödinger equation introduced by Strunz, Diósi, and Gisin [Phys. Rev. Lett. 82, 1801 (1999)]. Using a quantum-measurement theory approach, we rederive their unraveling that involves complex-valued Gaussian noise. We also derive an unraveling involving real-valued Gaussian noise. We show that in the Markovian limit, these two unravelings correspond to heterodyne and homodyne detection, respectively. Although we use quantum-measurement theory to define these unravelings, we conclude that the stochastic evolution of the system state is not a true quantum trajectory, as the identity of the state through time is a fiction.

  4. Control of dangerous substances in discharges and microbiological abatement: European framework and a case study of an ozone disinfection system.

    PubMed

    Ostoich, M; Serena, F; Falletti, L; Fantoni, A

    2013-01-01

    Directive 2000/60/EC requires the achievement of a 'good chemical status' for surface water within pre-established dates. Disinfection is needed to achieve compulsory final microbial limit values (in Italy for wastewater discharges the parameter Escherichia coli - EC - is imposed by law with a maximum limit value of 5,000 cfu/100 mL). Liquid waste and disinfection by-products must be considered when designing appropriate monitoring of dangerous substances; the specific classes of substances must be investigated according to the typology of received wastewaters and liquid wastes (where applicable) and specific analytical techniques, with Limit of Detection (LOD) lower than the limit values, must be applied; the difficulties faced by national and regional environmental control Agencies is that these techniques have to be applied during ordinary activity and not only for research purposes. The study aims to present the control of dangerous substances, as a screening view, in wastewater treatment plant (WWTP) discharges in the province of Venice (Northern Italy) for the period 2007-2010 based on available data from institutional controls. In addition, the wastewater disinfection process with ozone applied to a medium size WWTP (45,000 Population Equivalents) is presented as a case study, with a view to assessing the microbiological abatement efficacy and the presence of dangerous substances. Discharge quality of the WWTPs in the province of Venice presented mean values that were higher than the LOD, but only for certain metals. For the Paese plant, zinc and chloroform were the only micro-pollutants detected with a higher level than the LOD. From microbiological data in the period 2006-2011 the disinfection abatement efficiency for Paese was, in most cases above 99% for EC, faecal coliform (FC), faecal streptococci (FS) while efficiency was slightly lower for total coliform (TC); however, the proposed criterion aimed at respecting 99.99% abatement was not completely satisfied. Therefore, despite the high organic and industrial load of the considered plant and the need to find an alternative system for chlorine, as chlorine disinfection has been banned in the Veneto region since December 2012, ozone efficiency is not completely satisfactory and other systems such as peracetic or performic acids and UV systems must be considered.

  5. Screening of phthalate esters in 47 branded perfumes.

    PubMed

    Al-Saleh, Iman; Elkhatib, Rola

    2016-01-01

    In the last few years, the use of phthalates in perfumes has gained attention because these chemicals are sometimes added intentionally as a solvent and a fixative. Five phthalate esters, dimethyl phthalate (DMP), diethyl phthalate (DEP), dibutyl phthalate (DBP), benzyl butyl phthalate (BBP), and diethyl hexyl phthalate (DEHP), were measured in 47 branded perfumes using headspace solid phase microextraction (SPME) followed by gas chromatography-mass spectrometry (GC-MS). The results revealed considerable amounts of phthalate in all 47 brands with detection frequencies > limit of quantitation in the following order: DEP (47/47) > DMP (47/47) > BBP (47/47) > DEHP (46/47) > DBP (23/45). Of the 47 brands, 68.1, 72.3, 85.1, 36.2, and 6.7 % had DEP, DMP, BBP, DEHP, and DBP levels, respectively, above their reported threshold limits. Of these phthalates, DEP was found to have the highest mean value (1621.625 ppm) and a maximum of 23,649.247 ppm. The use of DEP in the perfume industry is not restricted because it does not pose any known health risks for humans. DMP had the second highest level detected in the perfumes, with a mean value of 30.202 ppm and a maximum of 405.235 ppm. Although DMP may have some uses in cosmetics, it is not as commonly used as DEP, and again, there are no restrictions on its use. The levels of BBP were also high, with a mean value of 8.446 ppm and a maximum of 186.770 ppm. Although the EU banned the use of BBP in cosmetics, 27 of the tested perfumes had BBP levels above the threshold limit of 0.1 ppm. The mean value of DEHP found in this study was 5.962 ppm, and a maximum was 147.536 ppm. In spite of its prohibition by the EU, 7/28 perfumes manufactured in European countries had DEHP levels above the threshold limit of 1 ppm. The DBP levels were generally low, with a mean value of 0.0305 ppm and a maximum value of 0.594 ppm. The EU banned the use of DBP in cosmetics; however, we found three brands that were above the threshold limit of 0.1 ppm, and all were manufactured in European countries. The results of this study are alarming and definitely need to be brought to the attention of the public and health regulators. Although some phthalate compounds are still used in cosmetics, many scientists and environmental activists have argued that phthalates are endocrine-disrupting chemicals that have not been yet proven to be safe for any use, including cosmetics. Phthalates may also have different degrees of estrogenic modes of action. Furthermore, we should not dismiss the widespread use of phthalates in everyday products and exposure to these chemicals from sources such as food, medications, and other personal care products.

  6. Methods of analysis by the U.S. Geological Survey National Water Quality Laboratory; determination of 86 volatile organic compounds in water by gas chromatography/mass spectrometry, including detections less than reporting limits

    USGS Publications Warehouse

    Connor, Brooke F.; Rose, Donna L.; Noriega, Mary C.; Murtaugh, Lucinda K.; Abney, Sonja R.

    1998-01-01

    This report presents precision and accuracy data for volatile organic compounds (VOCs) in the nanogram-per-liter range, including aromatic hydrocarbons, reformulated fuel components, and halogenated hydrocarbons using purge and trap capillary-column gas chromatography/mass spectrometry. One-hundred-four VOCs were initially tested. Of these, 86 are suitable for determination by this method. Selected data are provided for the 18 VOCs that were not included. This method also allows for the reporting of semiquantitative results for tentatively identified VOCs not included in the list of method compounds. Method detection limits, method performance data, preservation study results, and blank results are presented. The authors describe a procedure for reporting low-concentration detections at less than the reporting limit. The nondetection value (NDV) is introduced as a statistically defined reporting limit designed to limit false positives and false negatives to less than 1 percent. Nondetections of method compounds are reported as ?less than NDV.? Positive detections measured at less than NDV are reported as estimated concentrations to alert the data user to decreased confidence in accurate quantitation. Instructions are provided for analysts to report data at less than the reporting limits. This method can support the use of either method reporting limits that censor detections at lower concentrations or the use of NDVs as reporting limits. The data-reporting strategy for providing analytical results at less than the reporting limit is a result of the increased need to identify the presence or absence of environmental contaminants in water samples at increasingly lower concentrations. Long-term method detection limits (LTMDLs) for 86 selected compounds range from 0.013 to 2.452 micrograms per liter (?g/L) and differ from standard method detection limits (MDLs) in that the LTMDLs include the long-term variance of multiple instruments, multiple operators, and multiple calibrations over a longer time. For these reasons, LTMDLs are expected to be slightly higher than standard MDLs. Recoveries for all of the VOCs tested ranged from 36 (tert-butyl formate) to 155 percent (pentachlorobenzene). The majority of the compounds ranged from 85 to 115 percent recovery and had less than 5 percent relative standard deviation for concentrations spiked between 1 to 500 ?g/L in volatile blank-, surface-, and ground-water samples. Recoveries of 60 set spikes at low concentrations ranged from 70 to 114 percent (1,2,3- trimethylbenzene and acetone). Recovery data were collected over 6 months with multiple instruments, operators, and calibrations. In this method, volatile organic compounds are extracted from a water sample by actively purging with helium. The VOCs are collected onto a sorbent trap, thermally desorbed, separated by a Megabore gas chromatographic capillary column, and finally determined by a full-scan quadrupole mass spectrometer. Compound identification is confirmed by the gas chromatographic retention time and by the resultant mass spectrum, typically identified by three unique ions. An unknown compound detected in a sample can be tentatively identified by comparing the unknown mass spectrum to reference spectra in the mass-spectra computer-data system library compiled by the National Institute of Standards and Technology.

  7. First laboratory detection of an absorption line of the first overtone electric quadrupolar band of N2 by CRDS near 2.2 μm

    NASA Astrophysics Data System (ADS)

    Čermák, P.; Vasilchenko, S.; Mondelain, D.; Kassi, S.; Campargue, A.

    2017-01-01

    The extremely weak 2-0 O(14) electric quadrupole transition of N2 has been detected by very high sensitivity Cavity Ring Down spectroscopy near 4518 cm-1. It is the first N2 absorption line in the first overtone band reported so far from laboratory experiments. By combining a feedback narrowed Distributed Feedback laser diode with a passive cell tracking technique, a limit of detection of αmin ∼ 1.2 × 10-11 cm-1 was achieved after one day of spectra averaging. The N2 2-0 O(14) line position and line intensity (about 1.5 × 10-30 cm/molecule) agree with calculated values provided in the HITRAN2012 database.

  8. Enhanced amperometric detection of metronidazole in drug formulations and urine samples based on chitosan protected tetrasulfonated copper phthalocyanine thin-film modified glassy carbon electrode.

    PubMed

    Meenakshi, S; Pandian, K; Jayakumari, L S; Inbasekaran, S

    2016-02-01

    An enhanced electrocatalytic reduction of metronidazole antibiotic drug molecule using chitosan protected tetrasulfonated copper phthalocyanine (Chit/CuTsPc) thin-film modified glassy carbon electrode (GCE) has been developed. An irreversible reduction occurs at -0.47V (vs. Ag/AgCl) using Chit/CuTsPc modified GCE. A maximum peak current value is obtained at pH1 and the electrochemical reduction reaction is a diffusion controlled one. The detection limit is found to be 0.41nM from differential pulse voltammetry (DPV) method. This present investigation method is adopted for electrochemical detection of metronidazole in drug formulation and urine samples by using DPV method. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Ultraviolet spectrophotometry of comet Giacobini-Zinner during the ICE encounter. [International Cometary Explorer (ICE)

    NASA Technical Reports Server (NTRS)

    Ahearn, Michael F.; Mcfadden, Lucy A.; Feldman, Paul D.; Boehnhardt, Hermann; Rahe, Juergen; Festou, Michael; Brandt, John C.; Maran, Stephen P.; Niedner, Malcom B.; Smith, Andrew M.

    1986-01-01

    The IUE spectrophotometry of Comet P/Giacobini-Zinner was acquired in support of the International Cometary Explorer (ICE) mission. The abundances (or upper limits) of UV-active species were calculated. During the ICE encounter the H2O production rate was 3 times 10 to the 28th power/sec, + or - 50%, consistent with values derived from the ICE experiments. Comparison of the abundance of CO2(+) ions with the total electron density measured by the plasma electron experiment on ICE indicates a deficiency of ions relative to electrons indicating a population of ions not detected by remote sensing. The absence of detectable Mg(+) rules out this species as a possible ion of M/Q = 24 detected by the Ion Composition Instrument, part of the ICE complement of instruments.

  10. Naphthaldimine-based simple glucose derivative as a highly selective sensor for colorimetric detection of Cu2+ ion in aqueous media

    NASA Astrophysics Data System (ADS)

    Dolai, Bholanath; Bhaumik, Atanu; Pramanik, Nabakumar; Ghosh, Kalyan Sundar; Atta, Ananta Kumar

    2018-07-01

    Naphthaldimine-based glucose derivatives 1 and 3 have been designed, synthesized and characterized. In aqueous media, glucose derivative 1, exhibited high selectivity and sensitivity towards Cu2+ ion in comparison with various cations and anions. In presence of Cu2+, sensor 1 has provided significant naked-eye detectable color change. The formation of 1-Cu2+ complex has been analyzed by UV-vis spectroscopy, 1H NMR titration experiments, mass spectrometry and DFT (density functional theory) calculations. Limit of detection of 1 as a colorimetric sensor for Cu2+ ion is found to be 0.23 μM, much lower than recommended value of World Health Organization (WHO), which makes to Cu2+ sensor 1 more effective and useful.

  11. Comparative Assessment of Anti-HLA Antibodies Using Two Commercially Available Luminex-Based Assays.

    PubMed

    Clerkin, Kevin J; See, Sarah B; Farr, Maryjane A; Restaino, Susan W; Serban, Geo; Latif, Farhana; Li, Lingzhi; Colombo, Paolo C; Vlad, George; Ray, Bryan; Vasilescu, Elena R; Zorn, Emmanuel

    2017-11-01

    Allospecific anti-HLA antibodies (Abs) are associated with rejection of solid organ grafts. The 2 main kits to detect anti-HLA Ab in patient serum are commercialized by Immucor and One Lambda/ThermoFisher. We sought to compare the performance of both platforms. Background-adjusted mean fluorescence intensity (MFI) values were used from both platforms to compare sera collected from 125 pretransplant and posttransplant heart and lung transplant recipients. Most HLA class I (94.5%) and HLA class II (89%) Abs with moderate to high MFI titer (≥4000) were detected by both assays. A modest correlation was observed between MFI values obtained from the 2 assays for both class I ( r = 0.3, r 2 = 0.09, P < 0.0001) and class II Ab ( r = 0.707, r 2 = 0.5, P < 0.0001). Both assays detected anti-class I and II Ab that the other did not; however, no specific HLA allele was detected preferentially by either of the 2 assays. For a limited number of discrepant sera, dilution resulted in comparable reactivity profiles between the 2 platforms. Immucor and One Lambda/ThermoFisher assays have a similar, albeit nonidentical, ability to detect anti-HLA Ab. Although the correlation between the assays was present, significant variances exist, some of which can be explained by a dilution-sensitive "prozone" effect.

  12. Comparative Assessment of Anti-HLA Antibodies Using Two Commercially Available Luminex-Based Assays

    PubMed Central

    Clerkin, Kevin J.; See, Sarah B.; Farr, Maryjane A.; Restaino, Susan W.; Serban, Geo; Latif, Farhana; Li, Lingzhi; Colombo, Paolo C.; Vlad, George; Ray, Bryan; Vasilescu, Elena R.; Zorn, Emmanuel

    2017-01-01

    Background Allospecific anti-HLA antibodies (Abs) are associated with rejection of solid organ grafts. The 2 main kits to detect anti-HLA Ab in patient serum are commercialized by Immucor and One Lambda/ThermoFisher. We sought to compare the performance of both platforms. Methods Background-adjusted mean fluorescence intensity (MFI) values were used from both platforms to compare sera collected from 125 pretransplant and posttransplant heart and lung transplant recipients. Results Most HLA class I (94.5%) and HLA class II (89%) Abs with moderate to high MFI titer (≥4000) were detected by both assays. A modest correlation was observed between MFI values obtained from the 2 assays for both class I (r = 0.3, r2 = 0.09, P < 0.0001) and class II Ab (r = 0.707, r2 = 0.5, P < 0.0001). Both assays detected anti–class I and II Ab that the other did not; however, no specific HLA allele was detected preferentially by either of the 2 assays. For a limited number of discrepant sera, dilution resulted in comparable reactivity profiles between the 2 platforms. Conclusions Immucor and One Lambda/ThermoFisher assays have a similar, albeit nonidentical, ability to detect anti-HLA Ab. Although the correlation between the assays was present, significant variances exist, some of which can be explained by a dilution-sensitive “prozone” effect. PMID:29184907

  13. Combined Dust Detection Algorithm by Using MODIS Infrared Channels over East Asia

    NASA Technical Reports Server (NTRS)

    Park, Sang Seo; Kim, Jhoon; Lee, Jaehwa; Lee, Sukjo; Kim, Jeong Soo; Chang, Lim Seok; Ou, Steve

    2014-01-01

    A new dust detection algorithm is developed by combining the results of multiple dust detectionmethods using IR channels onboard the MODerate resolution Imaging Spectroradiometer (MODIS). Brightness Temperature Difference (BTD) between two wavelength channels has been used widely in previous dust detection methods. However, BTDmethods have limitations in identifying the offset values of the BTDto discriminate clear-sky areas. The current algorithm overcomes the disadvantages of previous dust detection methods by considering the Brightness Temperature Ratio (BTR) values of the dual wavelength channels with 30-day composite, the optical properties of the dust particles, the variability of surface properties, and the cloud contamination. Therefore, the current algorithm shows improvements in detecting the dust loaded region over land during daytime. Finally, the confidence index of the current dust algorithm is shown in 10 × 10 pixels of the MODIS observations. From January to June, 2006, the results of the current algorithm are within 64 to 81% of those found using the fine mode fraction (FMF) and aerosol index (AI) from the MODIS and Ozone Monitoring Instrument (OMI). The agreement between the results of the current algorithm and the OMI AI over the non-polluted land also ranges from 60 to 67% to avoid errors due to the anthropogenic aerosol. In addition, the developed algorithm shows statistically significant results at four AErosol RObotic NETwork (AERONET) sites in East Asia.

  14. Immunofluorescence detection of pea protein in meat products.

    PubMed

    Petrášová, Michaela; Pospiech, Matej; Tremlová, Bohuslava; Javůrková, Zdeňka

    2016-08-01

    In this study we developed an immunofluorescence method to detect pea protein in meat products. Pea protein has a high nutritional value but in sensitive individuals it may be responsible for causing allergic reactions. We produced model meat products with various additions of pea protein and flour; the detection limit (LOD) of the method for pea flour was 0.5% addition, and for pea protein it was 0.001% addition. The repeatabilities and reproducibilities for samples both positive and negative for pea protein were all 100%. In a blind test with model products and commercial samples, there was no statistically significant difference (p > 0.05) between the declared concentrations of pea protein and flour and the immunofluorescence method results. Sensitivity was 1.06 and specificity was 1.00. These results show that the immunofluorescence method is suitable for the detection of pea protein in meat products.

  15. Detection of adulterated commercial Spanish beeswax.

    PubMed

    Serra Bonvehi, J; Orantes Bermejo, F J

    2012-05-01

    The physical and chemical parameters (melting point and saponification number), and the fraction of hydrocarbons, monoesters, acids and alcohols have been determined in 90 samples of Spanish commercial beeswax from Apis mellifera L. The adulteration with paraffins of different melting point, cow tallow, stearic acid, and carnauba wax were determined by HTGC-FID/MS detection, and the research was focussed mainly on paraffins and microcrystallines waxes. In general, the added adulterant can be identified by the presence of non-naturally beeswax components, and by the differences of values of selected components between pure and adulterated beeswax. The detection limits were determined using pure and adulterated beeswax with different amounts of added waxes (5%, 10%, 20% and 30%). Percentages higher than 1-5% of each adulterant can be detected in the mixtures. Paraffin waxes were confirmed in 33 of the 90 samples analysed at concentrations between 5% and 30%. Copyright © 2011 Elsevier Ltd. All rights reserved.

  16. Pork detection in binary meat mixtures and some commercial food products using conventional and real-time PCR techniques.

    PubMed

    Al-Kahtani, Hassan A; Ismail, Elsayed A; Asif Ahmed, Mohammed

    2017-03-15

    Pork DNA was detected in meat mixtures using both conventional PCR and real-time PCR (RT-PCR). Thirty meat mixtures containing beef, chicken, camel, rabbit, goat and sheep with varying percentage of pork (0%, 1%, 5%, 10%, and 20%) and 75 commercial food products, were analyzed using conventional and RT-PCR to determine the presence of pork DNA. Pork DNA standard curves and cycle threshold (Ct) values were used for quantification. The detection limits for pork DNA in the mixtures were 0.22, 0.047, 0.048, 0.0000037, 0.015ng/μl respectively. Unlike conventional PCR, RT-PCR detected pork DNA in nine processed food samples [chicken sausages (2), chicken luncheon (2), turkey meat loaf, milk chocolate with soft nougat, jelly, cake, and candies] at pork DNA concentrations of 0.0001ng/μl or less. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. Quantum-statistical theory of microwave detection using superconducting tunnel junctions

    NASA Astrophysics Data System (ADS)

    Deviatov, I. A.; Kuzmin, L. S.; Likharev, K. K.; Migulin, V. V.; Zorin, A. B.

    1986-09-01

    A quantum-statistical theory of microwave and millimeter-wave detection using superconducting tunnel junctions is developed, with a rigorous account of quantum, thermal, and shot noise arising from fluctuation sources associated with the junctions, signal source, and matching circuits. The problem of the noise characterization in the quantum sensitivity range is considered and a general noise parameter Theta(N) is introduced. This parameter is shown to be an adequate figure of merit for most receivers of interest while some devices can require a more complex characterization. Analytical expressions and/or numerically calculated plots for Theta(N) are presented for the most promising detection modes including the parametric amplification, heterodyne mixing, and quadratic videodetection, using both the quasiparticle-current and the Cooper-pair-current nonlinearities. Ultimate minimum values of Theta(N) for each detection mode are compared and found to be in agreement with limitations imposed by the quantum-mechanical uncertainty principle.

  18. [Monolithic column-gold composite substrate preparation and application to SERS detection of pigment].

    PubMed

    Xie, Yun-Fei; Li, Yan; Yu, Hui; Qian, He; Yao, Wei-Rong

    2014-03-01

    In the present study, we developed a novel SERS substrate with the porous monolith material combined with classic gold nanoparticles, and erythrosine as the research object, by adjusting the different experimental conditions for optimal SERS enhancements, including system pH and mixing time, and ultimately selected the optimum pH value 5.06 and mixing time 25 min. Compared with the traditional gold plastic substrate enhancement effect, the experimental conditions were applied to the monolith substrate SERS detection of dye erythrosine, different concentrations of samples were used for erythrosine SERS detection, and the detection limit reached 0.1 g x mL(-1). The method uses the payload of gold nanoparticles in mesoporous materials to effectively enhance the SERS signal. And this method has the advantages of simpleness and good stability, which provides a favorable theoretical basis for the rapid prohibited colorings screening.

  19. Determination of ammonium in river water and sewage samples by capillary zone electrophoresis with direct UV detection.

    PubMed

    Fukushi, Keiichi; Ito, Hideyuki; Kimura, Kenichi; Yokota, Kuriko; Saito, Keiitsu; Chayama, Kenji; Takeda, Sahori; Wakida, Shin-ichi

    2006-02-17

    We developed capillary zone electrophoresis (CZE) with direct UV detection for determination of ammonium in environmental water samples. Ammonium in the samples was partly converted into ammonia in the alkaline background electrolyte (BGE) during migration and was detected by molecular absorption of ammonia at 190 nm in approximately 7 min. The limit of detection (LOD) for ammonium was 0.24 mg/l (as nitrogen) at a signal-to-noise ratio of three. The respective values of the relative standard deviation (RSD) of peak area, peak height, and migration time for ammonium were 2.1, 1.8, and 0.46%. Major alkali and alkaline earth metal ions coexisting in the samples did not interfere with ammonium determination by the proposed method. The proposed method determined ammonium in surface water and sewage samples. The results were compared to those obtained using ion chromatography (IC).

  20. Label-free impedimetric immunosensor for sensitive detection of ochratoxin A.

    PubMed

    Radi, Abd-Elgawad; Muñoz-Berbel, Xavier; Lates, Vasilica; Marty, Jean-Louis

    2009-03-15

    A novel label-free electrochemical impedimetric immunosensor for sensitive detection of ochratoxin A (OTA) was reported. A two-step reaction protocol was elaborated to modify the gold electrode. The electrode was first derivatized by electrochemical reduction of in situ generated 4-carboxyphenyl diazonium salt (4-CPDS) in acidic aqueous solution yielded stable 4-carboxyphenyl (4-CP) monolayer. The ochratoxin A antibody was then immobilized making use of the carbodiimide chemistry. The steps of the immunosensor elaboration and the immunochemical reaction between ochratoxin A and the surface-bound antibody were interrogated using cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The impedance change, due to the specific immuno-interaction at the immunosensor surface was utilized to detect ochratoxin A. The increase in electron-transfer resistance (DeltaR(et)) values was linearly proportional to the concentration of OTA in the range of 1-20ngmL(-1), with a detection limit of 0.5ngmL(-1).

  1. The effect of laser ablation parameters on optical limiting properties of silver nanoparticles

    NASA Astrophysics Data System (ADS)

    Gursoy, Irmak; Yaglioglu, Halime Gul

    2017-09-01

    This paper presents the effect of laser ablation parameters on optical limiting properties of silver nanoparticles. The current applications of lasers such as range finding, guidance, detection, illumination and designation have increased the potential of damaging optical imaging systems or eyes temporary or permanently. The applications of lasers introduce risks for sensors or eyes, when laser power is higher than damage threshold of the detection system. There are some ways to protect these systems such as neutral density (nd) filters, shutters, etc. However, these limiters reduce the total amount of light that gets into the system. Also, response time of these limiters may not be fast enough to prevent damage and cause precipitation in performance due to deprivation of transmission or contrast. Therefore, optical limiting filters are needed that is transparent for low laser intensities and limit or block the high laser intensities. Metal nanoparticles are good candidates for such optical limiting filters for ns pulsed lasers or CW lasers due to their high damage thresholds. In this study we investigated the optical limiting performances of silver nanoparticles produced by laser ablation technique. A high purity silver target immersed in pure water was ablated with a Nd:YAG nanosecond laser at 532 nm. The effect of altering laser power and ablation time on laser ablation efficiency of nanoparticles was investigated experimentally and optimum values were specified. Open aperture Zscan experiment was used to investigate the effect of laser ablation parameters on the optical limiting performances of silver nanoparticles in pure water. It was found that longer ablation time decreases the optical limiting threshold. These results are useful for silver nanoparticles solutions to obtain high performance optical limiters.

  2. Assessment and improvement of statistical tools for comparative proteomics analysis of sparse data sets with few experimental replicates.

    PubMed

    Schwämmle, Veit; León, Ileana Rodríguez; Jensen, Ole Nørregaard

    2013-09-06

    Large-scale quantitative analyses of biological systems are often performed with few replicate experiments, leading to multiple nonidentical data sets due to missing values. For example, mass spectrometry driven proteomics experiments are frequently performed with few biological or technical replicates due to sample-scarcity or due to duty-cycle or sensitivity constraints, or limited capacity of the available instrumentation, leading to incomplete results where detection of significant feature changes becomes a challenge. This problem is further exacerbated for the detection of significant changes on the peptide level, for example, in phospho-proteomics experiments. In order to assess the extent of this problem and the implications for large-scale proteome analysis, we investigated and optimized the performance of three statistical approaches by using simulated and experimental data sets with varying numbers of missing values. We applied three tools, including standard t test, moderated t test, also known as limma, and rank products for the detection of significantly changing features in simulated and experimental proteomics data sets with missing values. The rank product method was improved to work with data sets containing missing values. Extensive analysis of simulated and experimental data sets revealed that the performance of the statistical analysis tools depended on simple properties of the data sets. High-confidence results were obtained by using the limma and rank products methods for analyses of triplicate data sets that exhibited more than 1000 features and more than 50% missing values. The maximum number of differentially represented features was identified by using limma and rank products methods in a complementary manner. We therefore recommend combined usage of these methods as a novel and optimal way to detect significantly changing features in these data sets. This approach is suitable for large quantitative data sets from stable isotope labeling and mass spectrometry experiments and should be applicable to large data sets of any type. An R script that implements the improved rank products algorithm and the combined analysis is available.

  3. A colorimetric and fluorometric dual-signal sensor for arginine detection by inhibiting the growth of gold nanoparticles/carbon quantum dots composite.

    PubMed

    Liu, Ting; Li, Na; Dong, Jiang Xue; Zhang, Ying; Fan, Yu Zhu; Lin, Shu Min; Luo, Hong Qun; Li, Nian Bing

    2017-01-15

    A bidimensional optical sensing platform which combines the advantages of fluorescence and colorimetry has been designed for arginine (Arg) detection. The system was established by monitoring the influence of Arg on the growth of gold nanoparticles/carbon quantum dots (Au/CQDs) composite, and the CQDs synthesized by ethylene glycol were used as the reducing and stabilizing agent in this paper. Considering that Arg is the only amino acid with guanidine group and has the highest isoelectric point (pI) value at 10.76, Arg would carry positive charges at pH 7.4. Consequently, the positively charged guanidine group of Arg could attract AuCl 4 - and CQDs through electrostatic interaction, which inhibited the growth of Au/CQDs composite. Thereby, the color of the system almost did not change and the fluorescence quenching of CQDs was prevented in the presence of Arg. Based on the color change a low detection limit for Arg was 37nM, and a detection limit of 450nM was obtained by fluorescence spectroscopy. Moreover, this dual-signal sensor also revealed excellent selectivity toward Arg over other amino acids. Besides, Arg can be detected in urine samples with satisfactory results, which demonstrate the potential applications for real analysis. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Exonuclease III-assisted graphene oxide amplified fluorescence anisotropy strategy for ricin detection.

    PubMed

    Xiao, Xue; Tao, Jing; Zhang, Hong Zhi; Huang, Cheng Zhi; Zhen, Shu Jun

    2016-11-15

    Graphene oxide (GO) is an excellent fluorescence anisotropy (FA) amplifier. However, in the conventional GO amplified FA strategy, one target can only induce the FA change of one fluorophore on probe, which limits the detection sensitivity. Herein, we developed an exonuclease III (Exo III) aided GO amplified FA strategy by using aptamer as an recognition element and ricin B-chain as a proof-of-concept target. The aptamer was hybridized with a blocker sequence and linked onto the surface of magnetic beads (MBs). Upon the addition of ricin B-chain, blocker was released from the surface of MBs and hybridized with the dye-modified probe DNA on the surface of GO through the toehold-mediated strand exchange reaction. The formed blocker-probe DNA duplex triggered the Exo III-assisted cyclic signal amplification by repeating the hybridization and digestion of probe DNA, liberating the fluorophore with several nucleotides (low FA value). Thus, ricin B-chain could be sensitively detected by the significantly decreased FA. The linear range was from 1.0μg/mL to 13.3μg/mL and the limit of detection (LOD) was 400ng/mL. This method improved the sensitivity of FA assay and it could be generalized to any kind of target detection based on the use of an appropriate aptamer. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Rapid discrimination between buffalo and cow milk and detection of adulteration of buffalo milk with cow milk using synchronous fluorescence spectroscopy in combination with multivariate methods.

    PubMed

    Durakli Velioglu, Serap; Ercioglu, Elif; Boyaci, Ismail Hakki

    2017-05-01

    This research paper describes the potential of synchronous fluorescence (SF) spectroscopy for authentication of buffalo milk, a favourable raw material in the production of some premium dairy products. Buffalo milk is subjected to fraudulent activities like many other high priced foodstuffs. The current methods widely used for the detection of adulteration of buffalo milk have various disadvantages making them unattractive for routine analysis. Thus, the aim of the present study was to assess the potential of SF spectroscopy in combination with multivariate methods for rapid discrimination between buffalo and cow milk and detection of the adulteration of buffalo milk with cow milk. SF spectra of cow and buffalo milk samples were recorded between 400-550 nm excitation range with Δλ of 10-100 nm, in steps of 10 nm. The data obtained for ∆λ = 10 nm were utilised to classify the samples using principal component analysis (PCA), and detect the adulteration level of buffalo milk with cow milk using partial least square (PLS) methods. Successful discrimination of samples and detection of adulteration of buffalo milk with limit of detection value (LOD) of 6% are achieved with the models having root mean square error of calibration (RMSEC) and the root mean square error of cross-validation (RMSECV) and root mean square error of prediction (RMSEP) values of 2, 7, and 4%, respectively. The results reveal the potential of SF spectroscopy for rapid authentication of buffalo milk.

  6. Role of MRA in the detection of intracranial aneurysm in the acute phase of subarachnoid hemorrhage.

    PubMed

    Pierot, Laurent; Portefaix, Christophe; Rodriguez-Régent, Christine; Gallas, Sophie; Meder, Jean-François; Oppenheim, Catherine

    2013-07-01

    Magnetic resonance angiography (MRA) has been evaluated for the detection of unruptured intracranial aneurysms with favorable results at 3 Tesla (3T) and with similar diagnostic accuracy as both 3D time-of-flight (3D-TOF) and contrast-enhanced (CE-MRA) MRA. However, the diagnostic value and place of MRA in the detection of ruptured aneurysms has been little evaluated. Thus, the goal of this prospective single-center series was to assess the feasibility and diagnostic value of 3T 3D-TOF MRA and CE-MRA for aneurysm detection in acute non-traumatic subarachnoid hemorrhage (SAH). From March 2006 to December 2007, all consecutive patients admitted to our hospital with acute non-traumatic SAH (≤10 days) were prospectively included in this study evaluating MRA in the diagnostic workup of SAH. Feasibility of MRA and sensitivity/specificity of 3D-TOF and CE-MRA were assessed compared with gold standard DSA. In all, 84 consecutive patients (45 women, 39 men; age 23-86 years) were included. The feasibility of MRA was low (43/84, 51.2%). The reasons given for patients not undergoing magnetic resonance imaging (MRI) examination were clinical status (27 patients), potential delay in aneurysm treatment (11 patients) and contraindications to MRI (three patients). In patients explored by MRA, the sensitivity of CE-MRA (95%) was higher compared with 3D-TOF (86%) with similar specificity (80%). Also, 3D-TOF missed five aneurysms while CE-MRA missed two. The value of MRA in the diagnostic workup of ruptured aneurysms is limited due to its low feasibility during the acute phase of bleeding. Sensitivity for aneurysm detection was good for both MRA techniques, but tended to be better with CE-MRA. Copyright © 2013. Published by Elsevier Masson SAS.

  7. High-rate x-ray spectroscopy in mammography with a CdTe detector: a digital pulse processing approach.

    PubMed

    Abbene, L; Gerardi, G; Principato, F; Del Sordo, S; Ienzi, R; Raso, G

    2010-12-01

    Direct measurement of mammographic x-ray spectra under clinical conditions is a difficult task due to the high fluence rate of the x-ray beams as well as the limits in the development of high resolution detection systems in a high counting rate environment. In this work we present a detection system, based on a CdTe detector and an innovative digital pulse processing (DPP) system, for high-rate x-ray spectroscopy in mammography. The DPP system performs a digital pile-up inspection and a digital pulse height analysis of the detector signals, digitized through a 14-bit, 100 MHz digitizer, for x-ray spectroscopy even at high photon counting rates. We investigated on the response of the digital detection system both at low (150 cps) and at high photon counting rates (up to 500 kcps) by using monoenergetic x-ray sources and a nonclinical molybdenum anode x-ray tube. Clinical molybdenum x-ray spectrum measurements were also performed by using a pinhole collimator and a custom alignment device. The detection system shows excellent performance up to 512 kcps with an energy resolution of 4.08% FWHM at 22.1 keV. Despite the high photon counting rate (up to 453 kcps), the molybdenum x-ray spectra, measured under clinical conditions, are characterized by a low number of pile-up events. The agreement between the attenuation curves and the half value layer values, obtained from the measured spectra, simulated spectra, and from the exposure values directly measured with an ionization chamber, also shows the accuracy of the measurements. These results make the proposed detection system a very attractive tool for both laboratory research and advanced quality controls in mammography.

  8. [The use of galactomannan detection in diagnosing invasive aspergillosis in hemato-oncological patients].

    PubMed

    Rácil, Z; Kocmanová, I; Wagnerová, B; Winterová, J; Lengerová, M; Moulis, M; Mayer, J

    2008-01-01

    PREMISES AND OBJECTIVES: Timely diagnosis is of critical importance for the prognosis of invasive aspergilosis (IA) patients. Over recent years, IA detection of galactomannan using the ELISA method has assumed growing importance. The objective of the study was to analyse the usability of the method in current clinical practice of a hemato-oncological ward. From May 2003 to October 2006, blood samples were taken from patients at IA risk to detect galactomannan (GM) in serum using the ELISA method. The patients who underwent the tests were classified by the probability of IA presence on the basis of the results of conventional diagnostic methods and section findings. A total of 11,360 serum samples from 911 adult patients were tested for GM presence. IA (probable/proven) was diagnosed in 42 (4.6%) of them. The rates of sensitivity, specificity, positive and negative predictive value of galactomannan detection for IA diagnosis in our ward were, respectively, 95.2%, 90.0%, 31.5% and 99.7%. The principal causes of the limited positive predictive value of the test were the high percentage of false-positive test results (mainly caused by concomitant administration of some penicillin antibiotics or Plasma-Lyte infusion solution), as well as the fact that a large percentage of patients we examined fell within the group of patients with hematological malignity with a very low prevalence of IA. GM detection in serum is associated with high sensitivity and excellent negative predictive value in IA diagnosis in hemato-oncological patients. Knowledge and elimination of possible causes of false-positive results as well as focusing the screening on patients at greatest risk of infection are necessary for an even better exploitation of the test.

  9. Photoacoustic Studies on Iodine.

    NASA Astrophysics Data System (ADS)

    Bhan, Avtar N.

    A photoacoustic cavity was constructed which employs a temperature-controlled cylindrical cavity with optical windows at either end. It was operated in the lowest longitudinal mode using a small electret microphone for detecting the acoustic signal and a photomultiplier tube for detecting the optical signal. Molecular Iodine was used as the specimen gas and argon as the buffer gas. The photoacoustic characteristics of the system were studied. Iodine molecules, excited periodically by intensity modulated optical radiation (xenon discharge), de-excited by non-radiative processes which result in pressure waves having the same modulation frequency as that of the light. These pressure waves are detected as acoustical pulses by the microphone situated in the wall of the cavity. Studies were conducted for different pressures of buffer gas (100 torr to 800 torr) at several different Iodine pressures in the range between 0.3 and 1 torr. The longitudinal mode of excitation provides an opportunity to compare the response of the cavity under acoustical excitation with that under optical excitation. The relevant parameters in the investigation were: Q, the quality factor of the cavity; the resonant frequency, partial pressures of argon and Iodine; temperature; and the signal amplitude. It was found that the Q of the cavity was well -behaved following the theoretically predicted dependence on SQRT.(P and on T('- 3/4). The absorption coefficient of Iodine determined photometrically, increased with increasing argon pressure up to a limiting value of pressure that depended on Iodine concentration. The photoacoustic signal showed a similar increase with increasing argon pressure. This signal reached a limiting value at a pressure which corresponded closely with that found optically. This is taken to indicate that the extinction coefficient of Iodine in argon, at the level of dilution used in these studies, depends on the argon pressure. A method was developed for measuring the concentration of Iodine at low levels through application of the shift in the frequency of the longitudinal mode resonance of the cavity. Also, resonance technique was employed for determining the velocity of sound in argon. A value of 307.7 M/sec was established as compared with the value of 319 M/sec as reported in various standard handbooks.

  10. Clinical value of polymerase chain reaction in the diagnosis of joint tuberculosis by detecting the DNA of Mycobacterium tuberculosis.

    PubMed

    Sun, Yong-sheng; Lou, Si-quan; Wen, Jian-min; Lv, Wei-xin; Jiao, Chang-geng; Yang, Su-min; Xu, Hai-bin

    2011-02-01

    To assess the clinical value of polymerase chain reaction (PCR) in the diagnosis and differential diagnosis of joint tuberculosis (TB). PCR was used blindly to detect the DNA of Mycobacterium tuberculosis (M.TB) in five specimens of M.TB, 5 of BCG, and 10 of other bacteria. Then, M. TB in 98 samples from patients with joint TB and 100 samples from patients with non-tubercular joint disorders were detected by PCR, acid-fast staining and culture,. The sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of PCR were calculated. The χ2 test was used for statistical analysis of the frequency of various factors. At the same time, some problems with PCR were also systematically analyzed. (1) In the "standard samples", both M. TB and BCG showed positive while other bacteria were negative. (2) In 98 cases from patients with joint TB, 81 were positive by PCR, 6 by acid-fast staining, and 17 by culture. In 100 cases from patients with non-tuberculous joint disorders, 9 were positive by PCR, and none by either acid-fast staining or culture. Sensitivity, specificity, accuracy, positive and negative predictive value of PCR were 82.65% (81/98), 91.00% (91/100), 86.87% (172/198), 90.00% (81/90) and 84.26% (91/108), respectively. (3) The positive rates for PCR, acid-fast staining and culture in detection of M. TB were 82.65% (81/98), 6.12% (6/98), and 17.34% (17/98), respectively. There were statistically significant differences between the three methods (P < 0.001). (4) The process of PCR is automatic, and can be completed within 3 to 6 hours, whereas 4 to 8 weeks are required for the conventional culture of M. TB. PCR is a sensitive, specific, rapid, simple and minimally invasive method for detection of M. TB in samples from joint TB, and can play an important role in early and rapid diagnosis and differential diagnosis of joint TB. But it also has some limitations, such as false positivity and false negativity. © 2011 Tianjin Hospital and Blackwell Publishing Asia Pty Ltd.

  11. Smoke detection using GLCM, wavelet, and motion

    NASA Astrophysics Data System (ADS)

    Srisuwan, Teerasak; Ruchanurucks, Miti

    2014-01-01

    This paper presents a supervised smoke detection method that uses local and global features. This framework integrates and extends notions of many previous works to generate a new comprehensive method. First chrominance detection is used to screen areas that are suspected to be smoke. For these areas, local features are then extracted. The features are among homogeneity of GLCM and energy of wavelet. Then, global feature of motion of the smoke-color areas are extracted using a space-time analysis scheme. Finally these features are used to train an artificial intelligent. Here we use neural network, experiment compares importance of each feature. Hence, we can really know which features among those used by many previous works are really useful. The proposed method outperforms many of the current methods in the sense of correctness, and it does so in a reasonable computation time. It even has less limitation than conventional smoke sensors when used in open space. Best method for the experimental results is to use all the mentioned features as expected, to insure which is the best experiment result can be achieved. The achieved with high accuracy of result expected output is high value of true positive and low value of false positive. And show that our algorithm has good robustness for smoke detection.

  12. Directional templates for real-time detection of coronal axis rotated faces

    NASA Astrophysics Data System (ADS)

    Perez, Claudio A.; Estevez, Pablo A.; Garate, Patricio

    2004-10-01

    Real-time face and iris detection on video images has gained renewed attention because of multiple possible applications in studying eye function, drowsiness detection, virtual keyboard interfaces, face recognition, video processing and multimedia retrieval. In this paper, a study is presented on using directional templates in the detection of faces rotated in the coronal axis. The templates are built by extracting the directional image information from the regions of the eyes, nose and mouth. The face position is determined by computing a line integral using the templates over the face directional image. The line integral reaches a maximum when it coincides with the face position. It is shown an improvement in localization selectivity by the increased value in the line integral computed with the directional template. Besides, improvements in the line integral value for face size and face rotation angle was also found through the computation of the line integral using the directional template. Based on these results the new templates should improve selectivity and hence provide the means to restrict computations to a fewer number of templates and restrict the region of search during the face and eye tracking procedure. The proposed method is real time, completely non invasive and was applied with no background limitation and normal illumination conditions in an indoor environment.

  13. Noninvasive monitoring of fetal growth and development in the Siberian polecat (Mustela eversmanni)

    USGS Publications Warehouse

    Wimsatt, Jeffrey; Johnson, Jay D.; Wrigley, Robert H.; Biggins, Dean E.; Godbey, Jerry L.

    1998-01-01

    The Siberian polecat (Mustela eversmanni) is the preferred species to assess procedures and establish normative values for application in the related and endangered black-footed ferret (Mustela nigripes). This study was undertaken to physically, ultrasonographically, and radiographically evaluate fetal development in a spontaneously breeding captive Siberian polecat population. Ultrasonographically, fetal sac enlargement allowed presumptive preg nancy detection as early as 12 days of gestation, the fetal pole was the first definitive sign of pregnancy at about 18 days of gestation, when the fetal heart beat also appeared, and definitive pregnancy detection by ultrasound was essentially 100% accurate after 18 days. The estimation of fetal number by ultrasound was less reliable than by radiography, as it is in other litter-bearing species. Crown-rump growth, organ differentiation, and calcification patterns resembled those of domestic carnivores except that comparable developmental stages in polecats occurred at dispro portionately later times, suggesting that young Siberian polecats are delivered in a less developed state. Careful palpation permitted detection of pregnancy after day 17 but with less certainty than with ultrasound. Radiographic evaluation was insensitive and of limited value for pregnancy detection until near term. Litter number and fetal detail were difficult to assess until ossification could be observed, 3-6 days before parturition.

  14. Noninvasive monitoring of fetal growth and development in the Siberian polecat (Mustela eversmanni).

    PubMed

    Wimsatt, J; Johnson, J D; Wrigley, R H; Biggins, D E; Godbey, J L

    1998-12-01

    The Siberian polecat (Mustela eversmanni) is the preferred species to assess procedures and establish normative values for application in the related and endangered black-footed ferret (Mustela nigripes). This study was undertaken to physically, ultrasonographically, and radiographically evaluate fetal development in a spontaneously breeding captive Siberian polecat population. Ultrasonographically, fetal sac enlargement allowed presumptive pregnancy detection as early as 12 days of gestation, the fetal pole was the first definitive sign of pregnancy at about 18 days of gestation, when the fetal heart beat also appeared, and definitive pregnancy detection by ultrasound was essentially 100% accurate after 18 days. The estimation of fetal number by ultrasound was less reliable than by radiography, as it is in other litter-bearing species. Crown-rump growth, organ differentiation, and calcification patterns resembled those of domestic carnivores except that comparable developmental stages in polecats occurred at disproportionately later times, suggesting that young Siberian polecats are delivered in a less developed state. Careful palpation permitted detection of pregnancy after day 17 but with less certainty than with ultrasound. Radiographic evaluation was insensitive and of limited value for pregnancy detection until near term. Litter number and fetal detail were difficult to assess until ossification could be observed, 3-6 days before parturition.

  15. Visual and Plasmon Resonance Absorption Sensor for Adenosine Triphosphate Based on the High Affinity between Phosphate and Zr(IV).

    PubMed

    Qi, Wenjing; Liu, Zhongyuan; Zhang, Wei; Halawa, Mohamed Ibrahim; Xu, Guobao

    2016-10-12

    Zr(IV) can form phosphate and Zr(IV) (-PO₃ 2- -Zr 4+ -) complex owing to the high affinity between Zr(IV) with phosphate. Zr(IV) can induce the aggregation of gold nanoparticles (AuNPs), while adenosine triphosphate(ATP) can prevent Zr(IV)-induced aggregation of AuNPs. Herein, a visual and plasmon resonance absorption (PRA)sensor for ATP have been developed using AuNPs based on the high affinity between Zr(IV)with ATP. AuNPs get aggregated in the presence of certain concentrations of Zr(IV). After the addition of ATP, ATP reacts with Zr(IV) and prevents AuNPs from aggregation, enabling the detection of ATP. Because of the fast interaction of ATP with Zr(IV), ATP can be detected with a detection limit of 0.5 μM within 2 min by the naked eye. Moreover, ATP can be detected by the PRA technique with higher sensitivity. The A 520nm / A 650nm values in PRA spectra increase linearly with the concentrations of ATP from 0.1 μM to 15 μM (r = 0.9945) with a detection limit of 28 nM. The proposed visual and PRA sensor exhibit good selectivity against adenosine, adenosine monophosphate, guanosine triphosphate, cytidine triphosphate and uridine triphosphate. The recoveries for the analysis of ATP in synthetic samples range from 95.3% to 102.0%. Therefore, the proposed novel sensor for ATP is promising for real-time or on-site detection of ATP.

  16. Determination of β-blockers in pharmaceutical and human urine by capillary electrophoresis with electrochemiluminescence detection and studies on the pharmacokinetics.

    PubMed

    Wang, Yuanchao; Wu, Qiong; Cheng, Meirong; Cai, Cheng

    2011-04-15

    A novel method for simultaneous determination of atenolol, metoprolol and esmolol was proposed by capillary electrophoresis (CE) separation and electrochemiluminescence (ECL) detection. Poly-β-cyclodextrin (Poly-β-CD) was used as an additive in the running buffer to improve the separation of three analytes. The conditions for CE separation, ECL detection and effect of Poly-β-CD were investigated in detail. The three β-blockers with very similar structures were well separated and detected under the optimum conditions. The linear ranges of the standard solution for atenolol and esmolol were 2.5-125 μmol/L with a detection limit (S/N=3) of 0.5 μmol/L, and for metoprolol was 0.5-25 μmol/L with a detection limit of 0.1 μmol/L. For three β-blockers from spiked aqueous and urine samples, the accuracy and precision including intraday and interday experiments were performed by calculating the recovery, the relative standard deviations of the ECL intensity and the migration time, respectively. The developed method was applied to the determination of metoprolol content in commercial pharmaceutical, and the analytical results are in good agreement with the nominal value with recoveries in the range of 98.7-105%. The proposed method was also applied to the monitoring of pharmacokinetics for metoprolol in human body. Crown Copyright © 2011. Published by Elsevier B.V. All rights reserved.

  17. Multiplexed Paper Analytical Device for Quantification of Metals using Distance-Based Detection

    PubMed Central

    Cate, David M.; Noblitt, Scott D.; Volckens, John; Henry, Charles S.

    2015-01-01

    Exposure to metal-containing aerosols has been linked with adverse health outcomes for almost every organ in the human body. Commercially available techniques for quantifying particulate metals are time-intensive, laborious, and expensive; often sample analysis exceeds $100. We report a simple technique, based upon a distance-based detection motif, for quantifying metal concentrations of Ni, Cu, and Fe in airborne particulate matter using microfluidic paper-based analytical devices. Paper substrates are used to create sensors that are self-contained, self-timing, and require only a drop of sample for operation. Unlike other colorimetric approaches in paper microfluidics that rely on optical instrumentation for analysis, with distance-based detection, analyte is quantified visually based on the distance of a colorimetric reaction, similar to reading temperature on a thermometer. To demonstrate the effectiveness of this approach, Ni, Cu, and Fe were measured individually in single-channel devices; detection limits as low as 0.1, 0.1, and 0.05 µg were reported for Ni, Cu, and Fe. Multiplexed analysis of all three metals was achieved with detection limits of 1, 5, and 1 µg for Ni, Cu, and Fe. We also extended the dynamic range for multi-analyte detection by printing concentration gradients of colorimetric reagents using an off the shelf inkjet printer. Analyte selectivity was demonstrated for common interferences. To demonstrate utility of the method, Ni, Cu, and Fe were measured from samples of certified welding fume; levels measured with paper sensors matched known values determined gravimetrically. PMID:26009988

  18. Using large volume samplers for the monitoring of particle bound micro pollutants in rivers

    NASA Astrophysics Data System (ADS)

    Kittlaus, Steffen; Fuchs, Stephan

    2015-04-01

    The requirements of the WFD as well as substance emission modelling at the river basin scale require stable monitoring data for micro pollutants. The monitoring concepts applied by the local authorities as well as by many scientists use single sampling techniques. Samples from water bodies are usually taken in volumes of about one litre and depending on predetermined time steps or through discharge thresholds. For predominantly particle bound micro pollutants the small sample size of about one litre results in a very small amount of suspended particles. To measure micro pollutant concentrations in these samples is demanding and results in a high uncertainty of the measured concentrations, if the concentration is above the detection limit in the first place. In many monitoring programs most of the measured values were below the detection limit. This results in a high uncertainty if river loads were calculated from these data sets. The authors propose a different approach to gain stable concentration values for particle bound micro pollutants from river monitoring: A mixed sample of about 1000 L was pumped in a tank with a dirty-water pump. The sampling usually is done discharge dependant by using a gauge signal as input for the control unit. After the discharge event is over or the tank is fully filled, the suspended solids settle in the tank for 2 days. After this time a clear separation of water and solids can be shown. A sample (1 L) from the water phase and the total mass of the settled solids (about 10 L) are taken to the laboratory for analysis. While the micro pollutants can't hardly be detected in the water phase, the signal from the sediment is high above the detection limit, thus certain and very stable. From the pollutant concentration in the solid phase and the total tank volume the initial pollutant concentration in the sample can be calculated. If the concentration in the water phase is detectable, it can be used to correct the total load. This relatively low cost approach (less costs for analysis because of small sample number) allows to quantify the pollutant load, to derive dissolved-solid partition coefficients and to quantify the pollutant load in different particle size classes.

  19. Highly sensitive screening method for nitroaromatic, nitramine and nitrate ester explosives by high performance liquid chromatography-atmospheric pressure ionization-mass spectrometry (HPLC-API-MS) in forensic applications.

    PubMed

    Xu, Xiaoma; van de Craats, Anick M; de Bruyn, Peter C A M

    2004-11-01

    A highly sensitive screening method based on high performance liquid chromatography atmospheric pressure ionization mass spectrometry (HPLC-API-MS) has been developed for the analysis of 21 nitroaromatic, nitramine and nitrate ester explosives, which include the explosives most commonly encountered in forensic science. Two atmospheric pressure ionization (API) methods, atmospheric pressure chemical ionization (APCI) and electrospray ionization (ESI), and various experimental conditions have been applied to allow for the detection of all 21 explosive compounds. The limit of detection (LOD) in the full-scan mode has been found to be 0.012-1.2 ng on column for the screening of most explosives investigated. For nitrobenzene, an LOD of 10 ng was found with the APCI method in the negative mode. Although the detection of nitrobenzene, 2-, 3-, and 4-nitrotoluene is hindered by the difficult ionization of these compounds, we have found that by forming an adduct with glycine, LOD values in the range of 3-16 ng on column can be achieved. Compared with previous screening methods with thermospray ionization, the API method has distinct advantages, including simplicity and stability of the method applied, an extended screening range and a low detection limit for the explosives studied.

  20. Visual and surface plasmon resonance sensor for zirconium based on zirconium-induced aggregation of adenosine triphosphate-stabilized gold nanoparticles.

    PubMed

    Qi, Wenjing; Zhao, Jianming; Zhang, Wei; Liu, Zhongyuan; Xu, Min; Anjum, Saima; Majeed, Saadat; Xu, Guobao

    2013-07-17

    Owing to its high affinity with phosphate, Zr(IV) can induce the aggregation of adenosine 5'-triphosphate (ATP)-stabilized AuNPs, leading to the change of surface plasmon resonance (SPR) absorption spectra and color of ATP-stabilized AuNP solutions. Based on these phenomena, visual and SPR sensors for Zr(IV) have been developed for the first time. The A(660 nm)/A(518 nm) values of ATP-stabilized AuNPs in SPR absorption spectra increase linearly with the concentrations of Zr(IV) from 0.5 μM to 100 μM (r=0.9971) with a detection limit of 95 nM. A visual Zr(IV) detection is achieved with a detection limit of 30 μM. The sensor shows excellent selectivity against other metal ions, such as Cu(2+), Fe(3+), Cd(2+), and Pb(2+). The recoveries for the detection of 5 μM, 10 μM, 25 μM and 75 μM Zr(IV) in lake water samples are 96.0%, 97.0%, 95.6% and 102.4%, respectively. The recoveries of the proposed SPR method are comparable with those of ICP-OES method. Copyright © 2013 Elsevier B.V. All rights reserved.

  1. Determination of moclobemide in human plasma by high-performance liquid chromatography with spectrophotometric detection.

    PubMed

    Amini, Hossein; Shahmir, Badri; Ahmadiani, Abolhassan

    2004-08-05

    A simple and sensitive high-performance liquid chromatographic (HPLC) method with spectrophotometric detection was developed for the determination of moclobemide in human plasma. Plasma samples were extracted under basic conditions with dichloromethane followed by back-extraction into diluted phosphoric acid. Isocratic separation was employed on an ODS column (250 mm x 4.6 mm, 5 microm) at room temperature. The mobile phase consisted of 5 mM NaH2PO4-acetonitrile-triethylamine (1000:350:10 (v/v/v), pH 3.4). Analyses were run at a flow-rate of 1.0 ml/min and ultraviolet (UV) detection was carried out at 240 nm. The method was specific and sensitive with a quantification limit of 15.6 ng/ml and a detection limit of 5 ng/ml at a signal-to-noise ratio of 3:1. The mean absolute recovery was about 98.2%, while the intra- and inter-day coefficient of variation and percent error values of the assay method were all at acceptable levels. Linearity was assessed in the range of 15.6-2000 ng/ml in plasma with a correlation coefficient of greater than 0.999. This method has been used to analyze several hundred human plasma samples for bioavailibility studies.

  2. SEARCH FOR GAMMA RAY BURSTS WITH THE ARGO-YBJ DETECTOR IN SCALER MODE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aielli, G.; Camarri, P.; Bacci, C.

    2009-07-10

    We report on the search for gamma ray bursts (GRBs) in the energy range 1-100 GeV in coincidence with the prompt emission detected by satellites using the Astrophysical Radiation with Ground-based Observatory at YangBaJing (ARGO-YBJ) air shower detector. Thanks to its mountain location (Yangbajing, Tibet, People's Republic of China, 4300 m above sea level), active surface ({approx}6700 m{sup 2} of Resistive Plate Chambers), and large field of view ({approx}2 sr, limited only by the atmospheric absorption), the ARGO-YBJ air shower detector is particularly suitable for the detection of unpredictable and short duration events such as GRBs. The search is carriedmore » out using the 'single particle technique', i.e., counting all the particles hitting the detector without measurement of the energy and arrival direction of the primary gamma rays. Between 2004 December 17 and 2009 April 7, 81 GRBs detected by satellites occurred within the field of view of ARGO-YBJ (zenith angle {theta} {<=} 45 deg.). It was possible to examine 62 of these for >1 GeV counterpart in the ARGO-YBJ data finding no statistically significant emission. With a lack of detected spectra in this energy range fluence upper limits are profitable, especially when the redshift is known and the correction for the extragalactic absorption can be considered. The obtained fluence upper limits reach values as low as 10{sup -5} erg cm{sup -2} in the 1-100 GeV energy region. Besides this individual search for a higher energy counterpart, a statistical study of the stack of all the GRBs both in time and in phase was made, looking for a common feature in the GRB high-energy emission. No significant signal has been detected.« less

  3. Photon theory hypothesis about photon tunneling microscope's subwavelength resolution

    NASA Astrophysics Data System (ADS)

    Zhu, Yanbin; Ma, Junfu

    1995-09-01

    The foundation for the invention of the photon scanning tunneling microscope (PSTM) are the near field scanning optical microscope, the optical fiber technique, the total internal reflection, high sensitive opto-electronic detecting technique and computer technique etc. Recent research results show the subwavelength resolution of 1 - 3 nm is obtained. How to explain the PSTM has got such high subwavelength resolution? What value is the PSTM's limiting of subwavelength resolution? For resolving these problems this paper presented a photon theory hypothesis about PSTM that is based on the following two basic laws: (1) Photon is not only a carrier bringing energy and optical information, but also is a particle occupied fixed space size. (2) When a photon happened reflection, refraction, scattering, etc., only changed its energy and optical information carried, its particle size doesn't change. g (DOT) pphoton equals constant. Using these two basic laws to PSTM, the `evanescent field' is practically a weak photon distribution field and the detecting fiber tip diameter is practically a `gate' which size controlled the photon numbers into fiber tip. Passing through some calculation and inference, the following three conclusions can be given: (1) Under the PSTM's detection system sensitivity is high enough, the diameter D of detecting fiber tip and the near field detecting distance Z are the two most important factors to decide the subwavelength resolution of PSTM. (2) The limiting of PSTM's resolution will be given upon the conditions of D equals pphoton and Z equals pphoton, where pphoton is one photon size. (2) The final resolution limit R of PSTM will be lim R equals pphoton, D yields pphoton, Z yields pphoton.

  4. Upper limits on the 21 cm power spectrum at z = 5.9 from quasar absorption line spectroscopy

    NASA Astrophysics Data System (ADS)

    Pober, Jonathan C.; Greig, Bradley; Mesinger, Andrei

    2016-11-01

    We present upper limits on the 21 cm power spectrum at z = 5.9 calculated from the model-independent limit on the neutral fraction of the intergalactic medium of x_{H I} < 0.06 + 0.05 (1σ ) derived from dark pixel statistics of quasar absorption spectra. Using 21CMMC, a Markov chain Monte Carlo Epoch of Reionization analysis code, we explore the probability distribution of 21 cm power spectra consistent with this constraint on the neutral fraction. We present 99 per cent confidence upper limits of Δ2(k) < 10-20 mK2 over a range of k from 0.5 to 2.0 h Mpc-1, with the exact limit dependent on the sampled k mode. This limit can be used as a null test for 21 cm experiments: a detection of power at z = 5.9 in excess of this value is highly suggestive of residual foreground contamination or other systematic errors affecting the analysis.

  5. Assessment of the plasma desorption time-of-flight mass spectrometry technique for pesticide adsorption and degradation on 'as-received' treated soil samples.

    PubMed

    Thomas, J P; Nsouli, B; Darwish, T; Fallavier, M; Khoury, R; Wehbé, N

    2005-01-01

    The assessment of the plasma desorption time-of-flight mass spectrometry (PD-TOFMS) technique as a tool for direct characterization of pesticides adsorbed on agricultural soil is made for the first time in this study. Pellets of soils impregnated by solutions of three pesticides, namely norflurazon, malathion and oxyfluorfen, as well as deposits of these solutions onto aluminum surfaces, were investigated to this end. The yield values of the most characteristic peaks of the negative ion mass spectra were used to determine both the lowest concentrations detected on soils and limits of detection from thin films. The lowest values on soils are for malathion (1000 ppm range), and the largest for norflurazon (20,000 ppm), which is close to the limit of detection (LOD) found for the pesticide on the aluminum substrate (approximately 0.2 microg . cm(-2)). Different behaviors were observed as a function of time of storage in the ambient atmosphere or under vacuum; norflurazon adsorbed on soil exhibited high stability for a long period of time, and a rapid degradation of malathion with the elapsed time was clearly observed. The behavior of oxyfluorfen was also investigated but segregation processes seem to occur after several days. Although by far less sensitive than conventional methods based on extraction processes and used for real-world analytical applications, this technique is well suited to the study of the transformations occurring at the sample surface. A discussion is presented of the future prospects of such experiments in degradation studies. Copyright (c) 2005 John Wiley & Sons, Ltd.

  6. Data mining spacecraft telemetry: towards generic solutions to automatic health monitoring and status characterisation

    NASA Astrophysics Data System (ADS)

    Royer, P.; De Ridder, J.; Vandenbussche, B.; Regibo, S.; Huygen, R.; De Meester, W.; Evans, D. J.; Martinez, J.; Korte-Stapff, M.

    2016-07-01

    We present the first results of a study aimed at finding new and efficient ways to automatically process spacecraft telemetry for automatic health monitoring. The goal is to reduce the load on the flight control team while extending the "checkability" to the entire telemetry database, and provide efficient, robust and more accurate detection of anomalies in near real time. We present a set of effective methods to (a) detect outliers in the telemetry or in its statistical properties, (b) uncover and visualise special properties of the telemetry and (c) detect new behavior. Our results are structured around two main families of solutions. For parameters visiting a restricted set of signal values, i.e. all status parameters and about one third of all the others, we focus on a transition analysis, exploiting properties of Poincare plots. For parameters with an arbitrarily high number of possible signal values, we describe the statistical properties of the signal via its Kernel Density Estimate. We demonstrate that this allows for a generic and dynamic approach of the soft-limit definition. Thanks to a much more accurate description of the signal and of its time evolution, we are more sensitive and more responsive to outliers than the traditional checks against hard limits. Our methods were validated on two years of Venus Express telemetry. They are generic for assisting in health monitoring of any complex system with large amounts of diagnostic sensor data. Not only spacecraft systems but also present-day astronomical observatories can benefit from them.

  7. Effects of pH values of hydrogen peroxide bleaching agents on enamel surface properties.

    PubMed

    Xu, B; Li, Q; Wang, Y

    2011-01-01

    This study investigated the influence of pH values of bleaching agents on the properties of the enamel surface. Sixty freshly extracted premolars were embedded in epoxy resin and mesiodistally sectioned through the buccal aspect into two parts. The sectioned slabs were distributed among six groups (n=10) and treated using different solutions. Group HCl was treated with HCl solution (pH=3.0) and served as a positive control. Group DW, stored in distilled water (pH=7.0), served as a negative control. Four treatment groups were treated using 30% hydrogen peroxide solutions with different pH values: group HP3 (pH=3.0), group HP5 (pH=5.0), group HP7 (pH=7.0), and group HP8 (pH=8.0). The buccal slabs were subjected to spectrophotometric evaluations. Scanning electron microscopy investigation and Micro-Raman spectroscopy were used to evaluate enamel surface morphological and chemical composition alterations. pH value has a significant influence on the color changes after bleaching (p<0.001). Tukey's multiple comparisons revealed that the order of color changes was HP8, HP7>HP5, HP3>HCl>DW. No obvious morphological alterations were detected on the enamel surface in groups DW, HP7, and HP8. The enamel surface of groups HCl and HP3 showed significant alterations with an erosion appearance. No obvious chemical composition changes were detected with respect to Micro-Raman analysis. Within the limitations of this study, it was concluded that no obvious morphological or chemical composition alterations of enamel surface were detected in the neutral or alkaline bleaching solutions. Bleaching solutions with lower pH values could result in more significant erosion of enamel, which represented a slight whitening effect.

  8. Added value of cardiac computed tomography for evaluation of mechanical aortic valve: Emphasis on evaluation of pannus with surgical findings as standard reference.

    PubMed

    Suh, Young Joo; Lee, Sak; Im, Dong Jin; Chang, Suyon; Hong, Yoo Jin; Lee, Hye-Jeong; Hur, Jin; Choi, Byoung Wook; Chang, Byung-Chul; Shim, Chi Young; Hong, Geu-Ru; Kim, Young Jin

    2016-07-01

    The added value of cardiac computed tomography (CT) with transesophageal echocardiography (TEE) for evaluating mechanical aortic valve (AV) dysfunction has not yet been investigated. The purposes of this study were to investigate the added value of cardiac CT for evaluation of mechanical AVs and diagnoses of pannus compared to TEE, with surgical findings of redo-aortic valve replacement (AVR) used as a standard reference. 25 patients who underwent redo-AVR due to mechanical AV dysfunction and cardiac CT before redo-AVR were included. The presence of pannus, encroachment ratio by pannus, and limitation of motion (LOM) were evaluated on CT. The diagnostic performance of pannus detection was compared using TEE, CT, and CT+TEE, with surgical findings as a standard reference. The added value of CT for diagnosing the cause of mechanical AV dysfunction was assessed compared to TTE+TEE. In two patients, CT analysis was not feasible due to severe metallic artifacts. On CT, pannus and LOM were found in 100% (23/23) and 60.9% (14/23). TEE identified pannus in 48.0% of patients (12/25). CT, TEE, and CT+TEE correctly identified pannus with sensitivity of 92.0%, 48.0%, and 92.0%, respectively (P=0.002 for CT vs. TEE). In 11 of 13 cases (84.6%) with inconclusive or negative TEE results for pannus, CT detected the pannus. Among 13 inconclusive cases of TTE+TEE for the cause of mechanical AV dysfunction, CT suggested 6 prosthetic valve obstruction (PVO) by pannus, 4 low-flow low-gradient PVO, and one LOM without significant PVO. Cardiac CT showed added diagnostic value with TEE in the detection of pannus as the cause of mechanical AV dysfunction. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  9. Trace metal contents of selected seeds and vegetables from oil producing areas of Nigeria.

    PubMed

    Wegwu, Matthew O; Omeodu, Stephen I

    2010-07-01

    The concentrations of accumulated trace metals in selected seeds and vegetables collected in the oil producing Rivers State of Nigeria were investigated. The values were compared with those of seeds and vegetables cultivated in Owerri, a less industrialized area in Nigeria. The lead (Pb) and cadmium (Cd) contents of the seeds obtained from Rivers State ranged between 0.10 and 0.23 microg/g dry weight, while those of the seeds cultivated in Owerri fell below the detection limit of 0.01 microg/g dry weight. The highest manganese (Mn) level (902 microg/g dry weight) was found in Irvingia garbonesis seeds cultivated in Rivers State. Similarly, the highest nickel (Ni) value (199 microg/g dry weight) was also obtained in I. garbonesis, however, in the seeds sampled in Owerri. The highest copper (Cu), zinc (Zn), and iron (Fe) levels (16.8, 5.27, and 26.2 microg/g dry weight, resp.) were detected in seeds collected in Rivers State. With the exception of Talinum triangulae, Ocinum gratissimum, and Piper guineese, with Pb levels of 0.09, 0.10, and 0.11 microg/g dry weight, respectively, the Pb and Cd levels in the vegetables grown in Owerri fell below the detection limit of 0.01 microg/g dry weight. The trace metal with the highest levels in all the vegetables studied was Mn, followed by Fe. The highest concentrations of Ni and Cu occurred in vegetables collected from Rivers State, while the highest level of Zn was observed in Piper guineese collected in Owerri, with a value of 21.4 microg/g dry weight. Although the trace metal concentrations of the seeds and vegetables collected in Rivers State tended to be higher than those of the seeds and vegetables grown in Owerri, the average levels of trace metals obtained in this study fell far below the WHO specifications for metals in foods.

  10. A model for preemptive maintenance of medical linear accelerators-predictive maintenance.

    PubMed

    Able, Charles M; Baydush, Alan H; Nguyen, Callistus; Gersh, Jacob; Ndlovu, Alois; Rebo, Igor; Booth, Jeremy; Perez, Mario; Sintay, Benjamin; Munley, Michael T

    2016-03-10

    Unscheduled accelerator downtime can negatively impact the quality of life of patients during their struggle against cancer. Currently digital data accumulated in the accelerator system is not being exploited in a systematic manner to assist in more efficient deployment of service engineering resources. The purpose of this study is to develop an effective process for detecting unexpected deviations in accelerator system operating parameters and/or performance that predicts component failure or system dysfunction and allows maintenance to be performed prior to the actuation of interlocks. The proposed predictive maintenance (PdM) model is as follows: 1) deliver a daily quality assurance (QA) treatment; 2) automatically transfer and interrogate the resulting log files; 3) once baselines are established, subject daily operating and performance values to statistical process control (SPC) analysis; 4) determine if any alarms have been triggered; and 5) alert facility and system service engineers. A robust volumetric modulated arc QA treatment is delivered to establish mean operating values and perform continuous sampling and monitoring using SPC methodology. Chart limits are calculated using a hybrid technique that includes the use of the standard SPC 3σ limits and an empirical factor based on the parameter/system specification. There are 7 accelerators currently under active surveillance. Currently 45 parameters plus each MLC leaf (120) are analyzed using Individual and Moving Range (I/MR) charts. The initial warning and alarm rule is as follows: warning (2 out of 3 consecutive values ≥ 2σ hybrid) and alarm (2 out of 3 consecutive values or 3 out of 5 consecutive values ≥ 3σ hybrid). A customized graphical user interface provides a means to review the SPC charts for each parameter and a visual color code to alert the reviewer of parameter status. Forty-five synthetic errors/changes were introduced to test the effectiveness of our initial chart limits. Forty-three of the forty-five errors (95.6 %) were detected in either the I or MR chart for each of the subsystems monitored. Our PdM model shows promise in providing a means for reducing unscheduled downtime. Long term monitoring will be required to establish the effectiveness of the model.

  11. Influences of Availability on Parameter Estimates from Site Occupancy Models with Application to Submersed Aquatic Vegetation

    USGS Publications Warehouse

    Gray, Brian R.; Holland, Mark D.; Yi, Feng; Starcevich, Leigh Ann Harrod

    2013-01-01

    Site occupancy models are commonly used by ecologists to estimate the probabilities of species site occupancy and of species detection. This study addresses the influence on site occupancy and detection estimates of variation in species availability among surveys within sites. Such variation in availability may result from temporary emigration, nonavailability of the species for detection, and sampling sites spatially when species presence is not uniform within sites. We demonstrate, using Monte Carlo simulations and aquatic vegetation data, that variation in availability and heterogeneity in the probability of availability may yield biases in the expected values of the site occupancy and detection estimates that have traditionally been associated with low-detection probabilities and heterogeneity in those probabilities. These findings confirm that the effects of availability may be important for ecologists and managers, and that where such effects are expected, modification of sampling designs and/or analytical methods should be considered. Failure to limit the effects of availability may preclude reliable estimation of the probability of site occupancy.

  12. A malware detection scheme based on mining format information.

    PubMed

    Bai, Jinrong; Wang, Junfeng; Zou, Guozhong

    2014-01-01

    Malware has become one of the most serious threats to computer information system and the current malware detection technology still has very significant limitations. In this paper, we proposed a malware detection approach by mining format information of PE (portable executable) files. Based on in-depth analysis of the static format information of the PE files, we extracted 197 features from format information of PE files and applied feature selection methods to reduce the dimensionality of the features and achieve acceptable high performance. When the selected features were trained using classification algorithms, the results of our experiments indicate that the accuracy of the top classification algorithm is 99.1% and the value of the AUC is 0.998. We designed three experiments to evaluate the performance of our detection scheme and the ability of detecting unknown and new malware. Although the experimental results of identifying new malware are not perfect, our method is still able to identify 97.6% of new malware with 1.3% false positive rates.

  13. A Malware Detection Scheme Based on Mining Format Information

    PubMed Central

    Bai, Jinrong; Wang, Junfeng; Zou, Guozhong

    2014-01-01

    Malware has become one of the most serious threats to computer information system and the current malware detection technology still has very significant limitations. In this paper, we proposed a malware detection approach by mining format information of PE (portable executable) files. Based on in-depth analysis of the static format information of the PE files, we extracted 197 features from format information of PE files and applied feature selection methods to reduce the dimensionality of the features and achieve acceptable high performance. When the selected features were trained using classification algorithms, the results of our experiments indicate that the accuracy of the top classification algorithm is 99.1% and the value of the AUC is 0.998. We designed three experiments to evaluate the performance of our detection scheme and the ability of detecting unknown and new malware. Although the experimental results of identifying new malware are not perfect, our method is still able to identify 97.6% of new malware with 1.3% false positive rates. PMID:24991639

  14. Detection of cow milk adulteration in yak milk by ELISA.

    PubMed

    Ren, Q R; Zhang, H; Guo, H Y; Jiang, L; Tian, M; Ren, F Z

    2014-10-01

    In the current study, a simple, sensitive, and specific ELISA assay using a high-affinity anti-bovine β-casein monoclonal antibody was developed for the rapid detection of cow milk in adulterated yak milk. The developed ELISA was highly specific and could be applied to detect bovine β-casein (10-8,000 μg/mL) and cow milk (1:1,300 to 1:2 dilution) in yak milk. Cross-reactivity was <1% when tested against yak milk. The linear range of adulterant concentration was 1 to 80% (vol/vol) and the minimum detection limit was 1% (vol/vol) cow milk in yak milk. Different treatments, including heating, acidification, and rennet addition, did not interfere with the assay. Moreover, the results were highly reproducible (coefficient of variation <10%) and we detected no significant differences between known and estimated values. Therefore, this assay is appropriate for the routine analysis of yak milk adulterated with cow milk. Copyright © 2014 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  15. Liquid crystal based biosensors for bile acid detection

    NASA Astrophysics Data System (ADS)

    He, Sihui; Liang, Wenlang; Tanner, Colleen; Fang, Jiyu; Wu, Shin-Tson

    2013-03-01

    The concentration level of bile acids is a useful indicator for early diagnosis of liver diseases. The prevalent measurement method in detecting bile acids is the chromatography coupled with mass spectrometry, which is precise yet expensive. Here we present a biosensor platform based on liquid crystal (LC) films for the detection of cholic acid (CA). This platform has the advantage of low cost, label-free, solution phase detection and simple analysis. In this platform, LC film of 4-Cyano-4'-pentylbiphenyl (5CB) was hosted by a copper grid supported with a polyimide-coated glass substrate. By immersing into sodium dodecyl sulfate (SDS) solution, the LC film was coated with SDS which induced a homeotropic anchoring of 5CB. Addition of CA introduced competitive adsorption between CA and SDS at the interface, triggering a transition from homeotropic to homogeneous anchoring. The detection limit can be tuned by changing the pH value of the solution from 12uM to 170uM.

  16. CNV-seq, a new method to detect copy number variation using high-throughput sequencing.

    PubMed

    Xie, Chao; Tammi, Martti T

    2009-03-06

    DNA copy number variation (CNV) has been recognized as an important source of genetic variation. Array comparative genomic hybridization (aCGH) is commonly used for CNV detection, but the microarray platform has a number of inherent limitations. Here, we describe a method to detect copy number variation using shotgun sequencing, CNV-seq. The method is based on a robust statistical model that describes the complete analysis procedure and allows the computation of essential confidence values for detection of CNV. Our results show that the number of reads, not the length of the reads is the key factor determining the resolution of detection. This favors the next-generation sequencing methods that rapidly produce large amount of short reads. Simulation of various sequencing methods with coverage between 0.1x to 8x show overall specificity between 91.7 - 99.9%, and sensitivity between 72.2 - 96.5%. We also show the results for assessment of CNV between two individual human genomes.

  17. Systematic review on the value of CT scanning in the diagnosis of anastomotic leakage after colorectal surgery.

    PubMed

    Kornmann, Verena N N; Treskes, Nikki; Hoonhout, Lilian H F; Bollen, Thomas L; van Ramshorst, Bert; Boerma, Djamila

    2013-04-01

    Timely diagnosis of anastomotic leakage after colorectal surgery and adequate treatment is important to reduce morbidity and mortality. Abdominal computed tomography (CT) scanning is the diagnostic tool of preference, but its value may be questionable in the early postoperative period. The accuracy of CT scanning for the detection of anastomotic leakage and its role in timing of intervention was evaluated. A systematic literature search was performed. Relevant publications were identified from four electronic databases between 1990 and 2011. Inclusion criteria were human studies, studies published in English or Dutch, colorectal surgery with primary anastomosis, and abdominal CT scan with reported outcome for the detection of anastomotic leakage. Exclusion criteria were cohort of fewer than five patients, other gastrointestinal surgery, no anastomosis, and radiological imaging other than CT. Eight studies, including 221 abdominal CT scans, fulfilled the inclusion criteria. Overall, the methodological quality of the studies was poor. The overall sensitivity of CT scanning to diagnose leakage was 0.68 (95 % confidence interval 0.59-0.75) for colonic resection. Data on the sequelae of false-negative CT scanning was not available. There is limited good-quality evidence to determine the value of CT scans in the detection of anastomotic leakage. To prevent delay in diagnosis and appropriate treatment of anastomotic leakage, the relatively low sensitivity of CT scanning must be taken into account.

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shekhar, R.; Karunasagar, D.; Ranjit, M.

    An open-to-air type electrolyte cathode discharge (ELCAD) has been developed with a new design. The present configuration leads to a stable plasma even at low flow rates (0.96 mL/min). Plasma fluctuations arising from the variations in the gap between solid anode and liquid cathode were eliminated by providing a V-groove to the liquid glass-capillary. Cathode (ground) connection is given to the solution at the V-groove itself. Interfaced to atomic emission spectrometry (AES), its analytical performance is evaluated. The optimized molarity of the solution is 0.2 M. The analytical response curves for Ca, Cu, Cd, Pb, Hg, Fe, and Zn demonstratedmore » good linearity. The limit of detections of Ca, Cu, Cd, Pb, Hg, Fe, and Zn are determined to be 17, 11, 5, 45, 15, 28, and 3 ng mL{sup -1}. At an integration time of 0.3 s, the relative standard deviation (RSD) values of the acid blank solutions are found to be less than 10% for the elements Ca, Cu, Cd, Hg, Fe, and Zn and 18% for Pb. The method is applied for the determination of the elemental constituents in different matrix materials such as tuna fish (IAEA-350), oyster tissue (NIST SRM 1566a), and coal fly ash (CFA SRM 1633b). The obtained results are in good agreement with the certified values. The accuracy is found to be between 7% and 0.6% for major to trace levels of constituent elements and the precision between 11% and 0.6%. For the injection of 100 {mu} L of 200 ng mL{sup -1} mercury solution at the flow rate of 0.8 mL/min, the flow injection studies resulted in the relative standard deviation (RSD) of 8%, concentration detection limit of 10 ng/mL, and mass detection limit of 1 ng for mercury.« less

  19. Unambiguous quantum-state filtering

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Takeoka, Masahiro; Sasaki, Masahide; CREST, Japan Science and Technology Corporation, Tokyo,

    2003-07-01

    In this paper, we consider a generalized measurement where one particular quantum signal is unambiguously extracted from a set of noncommutative quantum signals and the other signals are filtered out. Simple expressions for the maximum detection probability and its positive operator valued measure are derived. We apply such unambiguous quantum state filtering to evaluation of the sensing of decoherence channels. The bounds of the precision limit for a given quantum state of probes and possible device implementations are discussed.

  20. Electrical Impedance Imaging for Early Detection of Breast Cancer for Young Women

    DTIC Science & Technology

    2013-12-01

    replacement therapy, prior biopsy, frequency of menstrual periods 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT 18. NUMBER OF PAGES...separate manual remediation databases were being used (one of which was at one point a copy of the other with some overlap of corrected values), there...in file" during manual remediation) . The Visits and Exams tables both had date variables and although the Menstrual History and All Findings tables

  1. Rapid Determination of the Chemical Oxygen Demand of Water Using a Thermal Biosensor

    PubMed Central

    Yao, Na; Wang, Jinqi; Zhou, Yikai

    2014-01-01

    In this paper we describe a thermal biosensor with a flow injection analysis system for the determination of the chemical oxygen demand (COD) of water samples. Glucose solutions of different concentrations and actual water samples were tested, and their COD values were determined by measuring the heat generated when the samples passed through a column containing periodic acid. The biosensor exhibited a large linear range (5 to 3000 mg/L) and a low detection limit (1.84 mg/L). It could tolerate the presence of chloride ions in concentrations of 0.015 M without requiring a masking agent. The sensor was successfully used for detecting the COD values of actual samples. The COD values of water samples from various sources were correlated with those obtained by the standard dichromate method; the linear regression coefficient was found to be 0.996. The sensor is environmentally friendly, economical, and highly stable, and exhibits good reproducibility and accuracy. In addition, its response time is short, and there is no danger of hazardous emissions or external contamination. Finally, the samples to be tested do not have to be pretreated. These results suggest that the biosensor is suitable for the continuous monitoring of the COD values of actual wastewater samples. PMID:24915178

  2. [An improved algorithm for electrohysterogram envelope extraction].

    PubMed

    Lu, Yaosheng; Pan, Jie; Chen, Zhaoxia; Chen, Zhaoxia

    2017-02-01

    Extraction uterine contraction signal from abdominal uterine electromyogram(EMG) signal is considered as the most promising method to replace the traditional tocodynamometer(TOCO) for detecting uterine contractions activity. The traditional root mean square(RMS) algorithm has only some limited values in canceling the impulsive noise. In our study, an improved algorithm for uterine EMG envelope extraction was proposed to overcome the problem. Firstly, in our experiment, zero-crossing detection method was used to separate the burst of uterine electrical activity from the raw uterine EMG signal. After processing the separated signals by employing two filtering windows which have different width, we used the traditional RMS algorithm to extract uterus EMG envelope. To assess the performance of the algorithm, the improved algorithm was compared with two existing intensity of uterine electromyogram(IEMG) extraction algorithms. The results showed that the improved algorithm was better than the traditional ones in eliminating impulsive noise present in the uterine EMG signal. The measurement sensitivity and positive predictive value(PPV) of the improved algorithm were 0.952 and 0.922, respectively, which were not only significantly higher than the corresponding values(0.859 and 0.847) of the first comparison algorithm, but also higher than the values(0.928 and 0.877) of the second comparison algorithm. Thus the new method is reliable and effective.

  3. Liquid paraffin as new dilution medium for the analysis of high boiling point residual solvents with static headspace-gas chromatography.

    PubMed

    D'Autry, Ward; Zheng, Chao; Bugalama, John; Wolfs, Kris; Hoogmartens, Jos; Adams, Erwin; Wang, Bochu; Van Schepdael, Ann

    2011-07-15

    Residual solvents are volatile organic compounds which can be present in pharmaceutical substances. A generic static headspace-gas chromatography analysis method for the identification and control of residual solvents is described in the European Pharmacopoeia. Although this method is proved to be suitable for the majority of samples and residual solvents, the method may lack sensitivity for high boiling point residual solvents such as N,N-dimethylformamide, N,N-dimethylacetamide, dimethyl sulfoxide and benzyl alcohol. In this study, liquid paraffin was investigated as new dilution medium for the analysis of these residual solvents. The headspace-gas chromatography method was developed and optimized taking the official Pharmacopoeia method as a starting point. The optimized method was validated according to ICH criteria. It was found that the detection limits were below 1μg/vial for each compound, indicating a drastically increased sensitivity compared to the Pharmacopoeia method, which failed to detect the compounds at their respective limit concentrations. Linearity was evaluated based on the R(2) values, which were above 0.997 for all compounds, and inspection of residual plots. Instrument and method precision were examined by calculating the relative standard deviations (RSD) of repeated analyses within the linearity and accuracy experiments, respectively. It was found that all RSD values were below 10%. Accuracy was checked by a recovery experiment at three different levels. Mean recovery values were all in the range 95-105%. Finally, the optimized method was applied to residual DMSO analysis in four different Kollicoat(®) sample batches. Copyright © 2011 Elsevier B.V. All rights reserved.

  4. Simultaneous tuning of electric field intensity and structural properties of ZnO: Graphene nanostructures for FOSPR based nicotine sensor.

    PubMed

    Tabassum, Rana; Gupta, Banshi D

    2017-05-15

    We report theoretical and experimental realization of a SPR based fiber optic nicotine sensor having coatings of silver and graphene doped ZnO nanostructure onto the unclad core of the optical fiber. The volume fraction (f) of graphene in ZnO was optimized using simulation of electric field intensity. Four types of graphene doped ZnO nanostructures viz. nanocomposites, nanoflowers, nanotubes and nanofibers were prepared using optimized value of f. The morphology, photoluminescence (PL) spectra and UV-vis spectra of these nanostructures were studied. The peak PL intensity was found to be highest for ZnO: graphene nanofibers. The optimized value of f in ZnO: graphene nanofiber was reconfirmed using UV-vis spectroscopy. The experiments were performed on the fiber optic probe fabricated with Ag/ZnO: graphene layer and optimized parameters for in-situ detection of nicotine. The interaction of nicotine with ZnO: graphene nanostructures alters the dielectric function of ZnO: graphene nanostructure which is manifested in terms of shift in resonance wavelength. From the sensing signal, the performance parameters were measured including sensitivity, limit of detection (LOD), limit of quantification (LOQ), stability, repeatability and selectivity. The real sample prepared using cigarette tobacco leaves and analyzed using the fabricated sensor makes it suitable for practical applications. The achieved values of LOD and LOQ are found to be unrivalled in comparison to the reported ones. The sensor possesses additional advantages such as, immunity to electromagnetic interference, low cost, capability of online monitoring, remote sensing. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Analytical characterization and clinical evaluation of an enzyme-linked immunosorbent assay for measurement of afamin in human plasma.

    PubMed

    Dieplinger, Benjamin; Egger, Margot; Gabriel, Christian; Poelz, Werner; Morandell, Elisabeth; Seeber, Beata; Kronenberg, Florian; Haltmayer, Meinhard; Mueller, Thomas; Dieplinger, Hans

    2013-10-21

    Comparative proteomics has recently identified afamin, the newest member of the albumin gene family, as a potential biomarker for ovarian cancer. The aim of this study was the analytical and clinical evaluation of a sandwich enzyme-linked immunosorbent assay for the determination of afamin in human plasma. We evaluated precision, linearity, and detection limit of the assay, analyte stability and biological variability, determined reference values and quantified afamin concentrations in various diseases. Within-run and total coefficients of variation were <10%. The method was linear across the tested measurement range. Detection limit was 7 mg/L for the assay. The analyte was stable for 24 h at room temperature, for 48 h at 4°C, and for at least one year at -20°C and -80°C. The reference change value for healthy individuals was 24%. Age- and sex-independent reference values in healthy blood donors were 45-99 mg/L (median 68 mg/L). In the clinical assay evaluation afamin plasma concentrations were modestly decreased in patients with heart failure. Patients with pneumonia or sepsis exhibited markedly decreased afamin plasma concentrations. However, patients with chronic renal disease or chronic obstructive pulmonary disease showed no difference in afamin plasma concentrations as compared to healthy individuals. Correlation analyses revealed an inverse association between afamin and inflammatory biomarkers. The afamin assay meets quality specifications for laboratory medicine. The results of the clinical assay evaluation revealed novel insights with respect to afamin as a potential negative acute phase protein and should encourage further studies. © 2013.

  6. Evaluation of radiochemical neutron activation analysis methods for determination of arsenic in biological materials.

    PubMed

    Paul, Rick L

    2011-01-01

    Radiochemical neutron activation analysis (RNAA) with retention on hydrated manganese dioxide (HMD) has played a key role in the certification of As in biological materials at NIST. Although this method provides very high and reproducible yields and detection limits at low microgram/kilogram levels, counting geometry uncertainties may arise from unequal distribution of As in the HMD, and arsenic detection limits may not be optimal due to significant retention of other elements. An alternate RNAA procedure with separation of arsenic by solvent extraction has been investigated. After digestion of samples in nitric and perchloric acids, As(III) is extracted from 2 M sulfuric acid solution into a solution of zinc diethyldithiocarbamate in chloroform. Counting of (76)As allows quantitation of arsenic. Addition of an (77)As tracer solution prior to dissolution allows correction for chemical yield and counting geometries, further improving reproducibility. The HMD and solvent extraction procedures for arsenic were compared through analysis of SRMs 1577c (bovine liver), 1547 (peach leaves), and 1575a (pine needles). Both methods gave As results in agreement with certified values with comparable reproducibility. However, the solvent extraction method yields a factor of 3 improvement in detection limits and is less time-consuming than the HMD method. The new method shows great promise for use in As certification in reference materials.

  7. A New Method for the Fast Analysis of Trihalomethanes in Tap and Recycled Waters Using Headspace Gas Chromatography with Micro-Electron Capture Detection.

    PubMed

    Alexandrou, Lydon D; Meehan, Barry J; Morrison, Paul D; Jones, Oliver A H

    2017-05-15

    Chemical disinfection of water supplies brings significant public health benefits by reducing microbial contamination. The process can however, result in the formation of toxic compounds through interactions between disinfectants and organic material in the source water. These new compounds are termed disinfection by-products (DBPs). The most common are the trihalomethanes (THMs) such as trichloromethane (chloroform), dichlorobromomethane, chlorodibromomethane and tribromomethane (bromoform); these are commonly reported as a single value for total trihalomethanes (TTHMs). Analysis of DBPs is commonly performed via time- and solvent-intensive sample preparation techniques such as liquid-liquid and solid phase extraction. In this study, a method using headspace gas chromatography with micro-electron capture detection was developed and applied for the analysis of THMs in drinking and recycled waters from across Melbourne (Victoria, Australia). The method allowed almost complete removal of the sample preparation step whilst maintaining trace level detection limits (>1 ppb). All drinking water samples had TTHM concentrations below the Australian regulatory limit of 250 µg/L but some were above the U.S. EPA limit of 60 µg/L. The highest TTHM concentration was 67.2 µg/L and lowest 22.9 µg/L. For recycled water, samples taken directly from treatment plants held significantly higher concentrations (153.2 µg/L TTHM) compared to samples from final use locations (4.9-9.3 µg/L).

  8. Approach for Pesticide Residue Analysis for Metabolite Prothioconazole-desthio in Animal Origin Food.

    PubMed

    Liu, Hui; Yao, Guojun; Liu, Xueke; Liu, Chang; Zhan, Jing; Liu, Donghui; Wang, Peng; Zhou, Zhiqiang

    2017-03-22

    Food safety problems such as damage to immune, nervous, and endocrine systems leading to cancer and malformations have received increasing attention. To achieve the maximum residue limits, the most discussed method of high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) is widely used with a advantage of high precision and resolution. Prothioconazole is a broad-spectrum thiocarbamate fungicide. It can rapidly metabolize to prothioconazole-desthio in different matrixes. Rapid and effective methods for the determination of prothioconazole-desthio in five kinds of different animal food were developed. Samples were extracted with acetonitrile or acetonitrile/water and determined by HPLC-MS/MS. The limit of detection and limit of quantification values of prothioconazole-desthio were 0.015 and 0.05 mg/kg for porcine liver and kidney, 0.0015 and 0.005 mg/kg for pork, and 0.003 and 0.01 mg/kg for eggs, together with 0.0012 and 0.004 mg/kg for milk of the detected method, respectively. A good linear regression trend can be observed in a certain concentration range for all of the animal food. At fortified levels, recoveries were between 83.6 and 105%, with relative standard deviations of 1.5-10.3%. A sample survey of 150 samples with 30 samples for each kind of animal food across the country was conducted and found that there was no prothioconazole-desthio detected in all samples.

  9. A Novel Isothermal Assay of Borrelia burgdorferi by Recombinase Polymerase Amplification with Lateral Flow Detection.

    PubMed

    Liu, Wei; Liu, Hui-Xin; Zhang, Lin; Hou, Xue-Xia; Wan, Kang-Lin; Hao, Qin

    2016-08-03

    A novel isothermal detection for recombinase polymerase amplification with lateral flow (LF-RPA) was established for Borrelia burgdorferi (B. burgdorferi) detection in this study. This assay with high sensitivity and specificity can get a visible result without any additional equipment in 30 min. We designed a pair of primers according to recA gene of B. burgdorferi strains and a methodology evaluation was performed. The results showed that the RPA assay based on the recA gene was successfully applied in B. burgdorferi detection, and its specific amplification was only achieved from the genomic DNA of B. burgdorferi. The detection limit of the new assay was about 25 copies of the B. burgdorferi genomic DNA. Twenty Lyme borreliosis patients' serum samples were detected by LF-RPA assay, real-time qPCR and nested-PCR. Results showed the LF-RPA assay is more effective than nested-PCR for its shorter reaction time and considerably higher detection rate. This method is of great value in clinical rapid detection for Lyme borreliosis. Using the RPA assay might be a megatrend for DNA detection in clinics and endemic regions.

  10. Low upper limit to methane abundance on Mars.

    PubMed

    Webster, Christopher R; Mahaffy, Paul R; Atreya, Sushil K; Flesch, Gregory J; Farley, Kenneth A

    2013-10-18

    By analogy with Earth, methane in the Martian atmosphere is a potential signature of ongoing or past biological activity. During the past decade, Earth-based telescopic observations reported "plumes" of methane of tens of parts per billion by volume (ppbv), and those from Mars orbit showed localized patches, prompting speculation of sources from subsurface bacteria or nonbiological sources. From in situ measurements made with the Tunable Laser Spectrometer (TLS) on Curiosity using a distinctive spectral pattern specific to methane, we report no detection of atmospheric methane with a measured value of 0.18 ± 0.67 ppbv corresponding to an upper limit of only 1.3 ppbv (95% confidence level), which reduces the probability of current methanogenic microbial activity on Mars and limits the recent contribution from extraplanetary and geologic sources.

  11. Quantitative liver ADC measurements using diffusion-weighted MRI at 3 Tesla: evaluation of reproducibility and perfusion dependence using different techniques for respiratory compensation.

    PubMed

    Larsen, Nis Elbrønd; Haack, Søren; Larsen, Lars Peter Skovgaard; Pedersen, Erik Morre

    2013-10-01

    Diffusion weighted imaging (DWI) of the liver suffers from low signal to noise making 3 Tesla (3 T) an attractive option, but 3 T data is scarce. It was the aim to study the influence of different b values and respiratory compensation methods (RCM) on the apparent diffusion coefficient (ADC) level and on ADC reproducibility at 3 T. Ten healthy volunteers and 12 patients with malignant liver lesions underwent repeated (2-22 days) breathhold, free-breathing and respiratory triggered DWI at 3 T using b values between 0 and 1,000 s/mm(2). The ADCs changed up to 150% in healthy livers and up to 48% in malignant lesions depending on b value combinations. Best ADC reproducibility in healthy livers were obtained with respiratory triggering (95% limits of agreement: ±0.12) and free-breathing (±0.14). In malignant lesions equivalent reproducibility was obtained with less RCM dependence. The use of a lower maximum b value (b = 500) decreased reproducibility (±0.14 to ±0.32) in both normal liver and malignant lesions. Large differences in absolute ADC values and reproducibility caused by varying combinations of clinically realistic b values were demonstrated. Different RCMs caused smaller differences. Lowering maximum b value to 500 increased limits of agreement up to a factor of two. Serial ADC changes larger than approximately 15% can be detected confidently on an individual basis in both malignant lesions and normal liver parenchyma at 3 T using appropriate b values and respiratory compensation.

  12. Calorific evaluation and energy potential of grape pomace

    NASA Astrophysics Data System (ADS)

    Burg, Patrik; Ludín, David; Rutkowski, Kazimierz; Krakowiak-Bal, Anna; Trávníček, Petr; Zemánek, Pavel; Turan, Jan; Višacki, Vladimir

    2016-04-01

    This article deals with energetic evaluation and potential of pomace - a waste product originating during production of grape wine. Calorimetric analysis of 19 grapevine varieties was performed in 2013 and 2014. The aim was to specify their combustible limit and the gross calorific value. The evaluations were performed on pristine pomace, pomace without seeds, and only on seeds themselves. The results obtained imply that pomace is an interesting energetic resource with a gross calorific value of 16.07-18.97 MJ kg-1. Lower calorific values were detected in pomace after seed separation ie 14.60-17.75 MJ kg-1; on the contrary, seeds alone had the highest calorific values of 19.78-21.13 MJ kg-1. It can be assumed from the results of energetic evaluation of pomace in Czech Republic conditions that, by purposeful and efficient usage of pomace, 6.4 GWh of electric energy and 28 GWh of thermal energy can be generated.

  13. Modified ion source triple quadrupole mass spectrometer gas chromatograph for polycyclic aromatic hydrocarbon analyses

    PubMed Central

    Anderson, Kim A.; Szelewski, Michael J.; Wilson, Glenn; Quimby, Bruce D.; Hoffman, Peter D.

    2015-01-01

    We describe modified gas chromatography electron-impact/triple-quadrupole mass spectrometry (GC–EI/MS/MS) utilizing a newly developed hydrogen-injected self-cleaning ion source and modified 9 mm extractor lens. This instrument, with optimized parameters, achieves quantitative separation of 62 polycyclic aromatic hydrocarbons (PAHs). Existing methods historically limited rigorous identification and quantification to a small subset, such as the 16 PAHs the US EPA has defined as priority pollutants. Without the critical source and extractor lens modifications, the off-the-shelf GC–EI/MS/MS system was unsuitable for complex PAH analysis. Separations were enhanced by increased gas flow, a complex GC temperature profile incorporating multiple isothermal periods, specific ramp rates, and a PAH-optimized column. Typical determinations with our refined GC–EI/MS/MS have a large linear range of 1–10,000 pg μl−1 and detection limits of <2 pg μl−1. Included in the 62 PAHs, multiple-reaction-monitoring (MRM) mode enabled GC-EI/MS/MS identification and quantitation of several constituents of the MW 302 PAHs isomers. Using calibration standards, values determined were within 5% of true values over many months. Standard curve r2 values were typically >0.998, exceptional for compounds which are archetypally difficult. With this method benzo[a]fluorene, benzo[b]fluorene, benzo[c]fluorene were fully separated as was benzo[b]fluoranthene, benzo[k]fluoranthene, and benzo[j]fluoranthene. Chrysene and triphenylene, were sufficiently separated to allow accurate quantitation. Mean limits of detection (LODs) across all PAHs were 1.02 ± 0.84 pg μl−1 with indeno[1,2,3-c,d] pyrene having the lowest LOD at 0.26 pg μl−1 and only two analytes above 2.0 pg μl−1; acenaphthalene (2.33 pg μl−1) and dibenzo[a,e]pyrene (6.44 pg μl−1). PMID:26454790

  14. Scale and Sampling Effects on Floristic Quality

    PubMed Central

    2016-01-01

    Floristic Quality Assessment (FQA) is increasingly influential for making land management decisions, for directing conservation policy, and for research. But, the basic ecological properties and limitations of its metrics are ill defined and not well understood–especially those related to sample methods and scale. Nested plot data from a remnant tallgrass prairie sampled annually over a 12-year period, were used to investigate FQA properties associated with species detection rates, species misidentification rates, sample year, and sample grain/area. Plot size had no apparent effect on Mean C (an area’s average Floristic Quality level), nor did species detection levels above 65% detection. Simulated species misidentifications only affected Mean C values at greater than 10% in large plots, when the replaced species were randomly drawn from the broader county-wide species pool. Finally, FQA values were stable over the 12-year study, meaning that there was no evidence that the metrics exhibit year effects. The FQA metric Mean C is demonstrated to be robust to varied sample methodologies related to sample intensity (plot size, species detection rate), as well as sample year. These results will make FQA measures even more appealing for informing land-use decisions, policy, and research for two reasons: 1) The sampling effort needed to generate accurate and consistent site assessments with FQA measures is shown to be far lower than what has previously been assumed, and 2) the stable properties and consistent performance of metrics with respect to sample methods will allow for a remarkable level of comparability of FQA values from different sites and datasets compared to other commonly used ecological metrics. PMID:27489959

  15. Quantitative and multiplexed detection for blood typing based on quantum dot-magnetic bead assay.

    PubMed

    Xu, Ting; Zhang, Qiang; Fan, Ya-Han; Li, Ru-Qing; Lu, Hua; Zhao, Shu-Ming; Jiang, Tian-Lun

    2017-01-01

    Accurate and reliable blood grouping is essential for safe blood transfusion. However, conventional methods are qualitative and use only single-antigen detection. We overcame these limitations by developing a simple, quantitative, and multiplexed detection method for blood grouping using quantum dots (QDs) and magnetic beads. In the QD fluorescence assay (QFA), blood group A and B antigens were quantified using QD labeling and magnetic beads, and the blood groups were identified according to the R value (the value was calculated with the fluorescence intensity from dual QD labeling) of A and B antigens. The optimized performance of QFA was established by blood typing 791 clinical samples. Quantitative and multiplexed detection for blood group antigens can be completed within 35 min with more than 10 5 red blood cells. When conditions are optimized, the assay performance is satisfactory for weak samples. The coefficients of variation between and within days were less than 10% and the reproducibility was good. The ABO blood groups of 791 clinical samples were identified by QFA, and the accuracy obtained was 100% compared with the tube test. Receiver-operating characteristic curves revealed that the QFA has high sensitivity and specificity toward clinical samples, and the cutoff points of the R value of A and B antigens were 1.483 and 1.576, respectively. In this study, we reported a novel quantitative and multiplexed method for the identification of ABO blood groups and presented an effective alternative for quantitative blood typing. This method can be used as an effective tool to improve blood typing and further guarantee clinical transfusion safety.

  16. Be-7 as a tracer for short-term soil surface changes - opportunities and limitations

    NASA Astrophysics Data System (ADS)

    Baumgart, Philipp

    2013-04-01

    Within the last 20 years the cosmogenic nuclide Beryllium-7 was successfully established as a suitable tracer element to detect soil surface changes with a high accuracy. Particularly soil erosion rates from single precipitation events are in the focus of different studies due to the short radioactive half-life of the Be-7 isotope. High sorption at topmost soil particles and immobility at given pH-values enable fine-scaled erosion modelling down to 2 mm increments. But some important challenging limitations require particular attention, starting from sampling up to the final data evaluation. E.g. these are the realisation of the fine increment soil collection, the limiting amount of measurable samples per campaign due to the short radioactive half-life and the specific requirements for the detector measurements. Both, the high potential and the challenging limitations are presented as well as future perspectives of that tracer method.

  17. Methods and apparatus using commutative error detection values for fault isolation in multiple node computers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Almasi, Gheorghe; Blumrich, Matthias Augustin; Chen, Dong

    Methods and apparatus perform fault isolation in multiple node computing systems using commutative error detection values for--example, checksums--to identify and to isolate faulty nodes. When information associated with a reproducible portion of a computer program is injected into a network by a node, a commutative error detection value is calculated. At intervals, node fault detection apparatus associated with the multiple node computer system retrieve commutative error detection values associated with the node and stores them in memory. When the computer program is executed again by the multiple node computer system, new commutative error detection values are created and stored inmore » memory. The node fault detection apparatus identifies faulty nodes by comparing commutative error detection values associated with reproducible portions of the application program generated by a particular node from different runs of the application program. Differences in values indicate a possible faulty node.« less

  18. Secondary electrospray ionization-ion mobility spectrometry for explosive vapor detection.

    PubMed

    Tam, Maggie; Hill, Herbert H

    2004-05-15

    The unique capability of secondary electrospray ionization (SESI) as a nonradioactive ionization source to detect analytes in both liquid and gaseous samples was evaluated using aqueous solutions of three common military explosives: cyclo-1,3,5-trimethylene-2,4,6-trinitramine (RDX), nitroglycerin (NG) and pentaerythritol tetranitrate (PETN). The adducts formed between the compounds and their respective dissociation product, RDX.NO(2)(-), NG.NO(3)(-), and PETN.NO(3)(-), gave the most intense signal for the individual compound but were more sensitive to temperature than other species. These autoadducts were identified as RDX.NO(2)(-), NG.NO(3)(-), and PETN.NO(3)(-) and had maximum signal intensity at 137, 100, and 125 degrees C, respectively. The reduced mobility values of the three compounds were constant over the temperature range from 75 to 225 degrees C. The signal-to-noise ratios for RDX, NG, and PETN at 50 mg L(-1) in methanol-water were 340, 270, and 170, respectively, with a nominal noise of 8 +/- 2 pA. In addition to the investigation of autoadduct formation, the concept of doping the ionization source with nonvolatile adduct-forming agents was investigated and described for the first time. The SESI-IMS detection limit for RDX was 116 microg L(-1) in the presence of a traditional volatile chloride dopant and 5.30 microg L(-1) in the presence of a nonvolatile nitrate dopant. In addition to a lower detection limit, the nitrate dopant also produced a greater response sensitivity and a higher limit of linearity than did the traditional volatile chloride dopant.

  19. Utility of bronchial lavage fluids for epithelial growth factor receptor mutation assay in lung cancer patients: Comparison between cell pellets, cell blocks and matching tissue specimens

    PubMed Central

    Asaka, Shiho; Yoshizawa, Akihiko; Nakata, Rie; Negishi, Tatsuya; Yamamoto, Hiroshi; Shiina, Takayuki; Shigeto, Shohei; Matsuda, Kazuyuki; Kobayashi, Yukihiro; Honda, Takayuki

    2018-01-01

    The detection of epidermal growth factor receptor (EGFR) mutations is necessary for the selection of suitable patients with non-small cell lung cancer (NSCLC) for treatment with EGFR tyrosine kinase inhibitors. Cytology specimens are known to be suitable for EGFR mutation detection, although tissue specimens should be prioritized; however, there are limited studies that examine the utility of bronchial lavage fluid (BLF) in mutation detection. The purpose of the present study was to investigate the utility of BLF specimens for the detection of EGFR mutations using a conventional quantitative EGFR polymerase chain reaction (PCR) assay. Initially, quantification cycle (Cq) values of cell pellets, cell-free supernatants and cell blocks obtained from three series of 1% EGFR mutation-positive lung cancer cell line samples were compared for mutation detection. In addition, PCR analysis of BLF specimens obtained from 77 consecutive NSCLC patients, detecting EGFR mutations was validated, and these results were compared with those for the corresponding formalin-fixed paraffin-embedded (FFPE) tissue specimens obtained by surgical resection or biopsy of 49 of these patients. The Cq values for mutation detection were significantly lower in the cell pellet group (average, 29.58) compared with the other groups, followed by those in cell-free supernatants (average, 34.15) and in cell blocks (average, 37.12) for all three series (P<0.05). Mutational status was successfully analyzed in 77 BLF specimens, and the results obtained were concordant with those of the 49 matching FFPE tissue specimens. Notably, EGFR mutations were even detected in 10 cytological specimens that contained insufficient tumor cells. EGFR mutation testing with BLF specimens is therefore a useful and reliable method, particularly when sufficient cancer cells are not obtained. PMID:29399190

  20. Development and validation of an Enzyme Linked Immunosorbent Assay (ELISA) test for the diagnosis of toxoplasmosis in Sri Lanka.

    PubMed

    Iddawela, D; Ehambaram, K; Kumarasiri, P V; Wijesundera, S

    2015-09-01

    ELISA is the most widely used form of diagnosis for toxoplasmosis. Several commercial kits are currently used in Sri Lanka. However, these kits are not affordable in resource-limited settings. Objectives Aim of this study was to develop a cost effective in-house ELISA for the detection of Toxoplasma antibody and to estimate the diagnostic accuracy compared to a commercial kit. Vero cell lines were inoculated with tachyzoites and harvested after 2-6 days and sonicated to obtain somatic antigen. The antigen was used as coating material in ELISA to detect antibodies against T. gondii in patient sera. Hundred and three patients' sera were analysed by in-house ELISA and kit ELISA. Optical density (OD) values were analysed statistically. Toxoplasma IgG avidity test was used to determine the chronic and acute phase of infection. The optimum working dilutions for antigen was 0.846 μg/ml and for serum 1 in 100. The optimal cut-off values for the in-house ELISA within the range 0.85 to 0.98 at which the sensitivity was 95.3% and specificity was 98.3. The OD values of in-house ELISA were compared with OD values of kit ELISA and the results showed strong correlation between the two tests. The results of our study demonstrated that our in-house ELISA for detection of T. gondii antibody was as sensitive and specific as the commercial kit used in this study. Thus, the in-house ELISA is a useful, costeffective tool for diagnostic and screening purposes.

  1. Trigger values for investigation of hormonal activity in drinking water and its sources using CALUX bioassays.

    PubMed

    Brand, Walter; de Jongh, Cindy M; van der Linden, Sander C; Mennes, Wim; Puijker, Leo M; van Leeuwen, Cornelis J; van Wezel, Annemarie P; Schriks, Merijn; Heringa, Minne B

    2013-05-01

    To screen for hormonal activity in water samples, highly sensitive in vitro CALUX bioassays are available which allow detection of estrogenic (ERα), androgenic (AR), progestagenic (PR), and glucocorticoid (GR) activities. This paper presents trigger values for the ERα, AR, PR, and GR CALUX bioassays for agonistic hormonal activities in (drinking) water, which define a level above which human health risk cannot be waived a priori and additional examination of specific endocrine activity may be warranted. The trigger values are based on 1) acceptable or tolerable daily intake (ADI/TDI) values of specific compounds, 2) pharmacokinetic factors defining their bioavailability, 3) estimations of the bioavailability of unknown compounds with equivalent hormonal activity, 4) relative endocrine potencies, and 5) physiological, and drinking water allocation factors. As a result, trigger values of 3.8ng 17β-estradiol (E2)-equivalents (eq)/L, 11ng dihydrotestosterone (DHT)-eq/L, 21ng dexamethasone (DEX)-eq/L, and 333ng Org2058-eq/L were derived. Benchmark Quotient (BQ) values were derived by dividing hormonal activity in water samples by the derived trigger using the highest concentrations detected in a recent, limited screening of Dutch water samples, and were in the order of (value) AR (0.41)>ERα (0.13)>GR (0.06)>PR (0.04). The application of trigger values derived in the present study can help to judge measured agonistic hormonal activities in water samples using the CALUX bioassays and help to decide whether further examination of specific endocrine activity followed by a subsequent safety evaluation may be warranted, or whether concentrations of such activity are of low priority with respect to health concerns in the human population. For instance, at one specific drinking water production site ERα and AR (but no GR and PR) activities were detected in drinking water, however, these levels are at least a factor 83 smaller than the respective trigger values, and therefore no human health risks are to be expected from hormonal activity in Dutch drinking water from this site. Copyright © 2013 Elsevier Ltd. All rights reserved.

  2. Comparison of Immunohistochemistry and Direct Sanger Sequencing for Detection of the BRAFV600E Mutation in Thyroid Neoplasm

    PubMed Central

    Oh, Hye-Seon; Kwon, Hyemi; Park, Suyeon; Kim, Mijin; Jeon, Min Ji; Kim, Tae Yong; Shong, Young Kee; Kim, Won Bae; Choi, Jene

    2018-01-01

    Background The BRAFV600E mutation is the most common genetic alteration identified in papillary thyroid carcinoma (PTC). Because of its costs effectiveness and sensitivity, direct Sanger sequencing has several limitations. The aim of this study was to evaluate the efficiency of immunohistochemistry (IHC) as an alternative method to detect the BRAFV600E mutation in preoperative and postoperative tissue samples. Methods We evaluated 71 patients who underwent thyroid surgery with the result of direct sequencing of the BRAFV600E mutation. IHC staining of the BRAFV600E mutation was performed in 49 preoperative and 23 postoperative thyroid specimens. Results Sixty-two patients (87.3%) had PTC, and of these, BRAFV600E was confirmed by direct sequencing in 57 patients (91.9%). In 23 postoperative tissue samples, the BRAFV600E mutation was detected in 16 samples (70%) by direct sequencing and 18 samples (78%) by IHC. In 24 fine needle aspiration (FNA) samples, BRAFV600E was detected in 18 samples (75%) by direct sequencing and 16 samples (67%) by IHC. In 25 core needle biopsy (CNB) samples, the BRAFV600E mutation was detected in 15 samples (60%) by direct sequencing and 16 samples (64%) by IHC. The sensitivity and specificity of IHC for detecting the BRAFV600E mutation were 77.8% and 66.7% in FNA samples and 99.3% and 80.0% in CNB samples. Conclusion IHC could be an alternative method to direct Sanger sequencing for BRAFV600E mutation detection both in postoperative and preoperative samples. However, application of IHC to detect the BRAFV600E mutation in FNA samples is of limited value compared with direct sequencing. PMID:29388401

  3. Material limitations on the detection limit in refractometry.

    PubMed

    Skafte-Pedersen, Peder; Nunes, Pedro S; Xiao, Sanshui; Mortensen, Niels Asger

    2009-01-01

    We discuss the detection limit for refractometric sensors relying on high-Q optical cavities and show that the ultimate classical detection limit is given by min {Δn} ≳ η, with n + iη being the complex refractive index of the material under refractometric investigation. Taking finite Q factors and filling fractions into account, the detection limit declines. As an example we discuss the fundamental limits of silicon-based high-Q resonators, such as photonic crystal resonators, for sensing in a bio-liquid environment, such as a water buffer. In the transparency window (λ ≳ 1100 nm) of silicon the detection limit becomes almost independent on the filling fraction, while in the visible, the detection limit depends strongly on the filling fraction because the silicon absorbs strongly.

  4. Investigation of the limitations of the highly pixilated CdZnTe detector for PET applications

    PubMed Central

    Komarov, Sergey; Yin, Yongzhi; Wu, Heyu; Wen, Jie; Krawczynski, Henric; Meng, Ling-Jian; Tai, Yuan-Chuan

    2016-01-01

    We are investigating the feasibility of a high resolution positron emission tomography (PET) insert device based on the CdZnTe detector with 350 μm anode pixel pitch to be integrated into a conventional animal PET scanner to improve its image resolution. In this paper, we have used a simplified version of the multi pixel CdZnTe planar detector, 5 mm thick with 9 anode pixels only. This simplified 9 anode pixel structure makes it possible to carry out experiments without a complete application-specific integrated circuits readout system that is still under development. Special attention was paid to the double pixel (or charge sharing) detections. The following characteristics were obtained in experiment: energy resolution full-width-at-half-maximum (FWHM) is 7% for single pixel and 9% for double pixel photoelectric detections of 511 keV gammas; timing resolution (FWHM) from the anode signals is 30 ns for single pixel and 35 ns for double pixel detections (for photoelectric interactions only the corresponding values are 20 and 25 ns); position resolution is 350 μm in x,y-plane and ~0.4 mm in depth-of-interaction. The experimental measurements were accompanied by Monte Carlo (MC) simulations to find a limitation imposed by spatial charge distribution. Results from MC simulations suggest the limitation of the intrinsic spatial resolution of the CdZnTe detector for 511 keV photoelectric interactions is 170 μm. The interpixel interpolation cannot recover the resolution beyond the limit mentioned above for photoelectric interactions. However, it is possible to achieve higher spatial resolution using interpolation for Compton scattered events. Energy and timing resolution of the proposed 350 μm anode pixel pitch detector is no better than 0.6% FWHM at 511 keV, and 2 ns FWHM, respectively. These MC results should be used as a guide to understand the performance limits of the pixelated CdZnTe detector due to the underlying detection processes, with the understanding of the inherent limitations of MC methods. PMID:23079763

  5. Investigation of the limitations of the highly pixilated CdZnTe detector for PET applications.

    PubMed

    Komarov, Sergey; Yin, Yongzhi; Wu, Heyu; Wen, Jie; Krawczynski, Henric; Meng, Ling-Jian; Tai, Yuan-Chuan

    2012-11-21

    We are investigating the feasibility of a high resolution positron emission tomography (PET) insert device based on the CdZnTe detector with 350 µm anode pixel pitch to be integrated into a conventional animal PET scanner to improve its image resolution. In this paper, we have used a simplified version of the multi pixel CdZnTe planar detector, 5 mm thick with 9 anode pixels only. This simplified 9 anode pixel structure makes it possible to carry out experiments without a complete application-specific integrated circuits readout system that is still under development. Special attention was paid to the double pixel (or charge sharing) detections. The following characteristics were obtained in experiment: energy resolution full-width-at-half-maximum (FWHM) is 7% for single pixel and 9% for double pixel photoelectric detections of 511 keV gammas; timing resolution (FWHM) from the anode signals is 30 ns for single pixel and 35 ns for double pixel detections (for photoelectric interactions only the corresponding values are 20 and 25 ns); position resolution is 350 µm in x,y-plane and ∼0.4 mm in depth-of-interaction. The experimental measurements were accompanied by Monte Carlo (MC) simulations to find a limitation imposed by spatial charge distribution. Results from MC simulations suggest the limitation of the intrinsic spatial resolution of the CdZnTe detector for 511 keV photoelectric interactions is 170 µm. The interpixel interpolation cannot recover the resolution beyond the limit mentioned above for photoelectric interactions. However, it is possible to achieve higher spatial resolution using interpolation for Compton scattered events. Energy and timing resolution of the proposed 350 µm anode pixel pitch detector is no better than 0.6% FWHM at 511 keV, and 2 ns FWHM, respectively. These MC results should be used as a guide to understand the performance limits of the pixelated CdZnTe detector due to the underlying detection processes, with the understanding of the inherent limitations of MC methods.

  6. Detection of urinary Vi antigen as a diagnostic test for typhoid fever.

    PubMed Central

    Taylor, D N; Harris, J R; Barrett, T J; Hargrett, N T; Prentzel, I; Valdivieso, C; Palomino, C; Levine, M M; Blake, P A

    1983-01-01

    Since Vi antigen is limited primarily to Salmonella typhi, it has been thought that detection of the antigen may be a useful method for diagnosing acute typhoid fever. The slide coagglutination method and enzyme-linked immunosorbent assay have recently been suggested as ways to detect small quantities of Vi antigen in urine. In Santiago, Chile, we compared the results of these two methods in patients with acute typhoid fever, paratyphoid fever, and other febrile illnesses and in afebrile control subjects. Using a cut-off value that maximally separated typhoid patients from controls, the enzyme-linked immunosorbent assay was positive in 62.4% of 141 patients with culture-proven typhoid infections and in 13.2% of 159 afebrile control subjects. The enzyme-linked immunosorbent assay was false positive in 64.7% of 34 culture-proven paratyphoid A or B patients and 47.1% of 21 patients with other nontyphoidal febrile illnesses. The coagglutination test was positive in 34% of typhoid patients, 14% of afebrile control subjects, and 46% of febrile control subjects. We conclude that these tests when performed with the Vi antibodies employed in this study are of little value for the diagnosis of typhoid fever in this setting. PMID:6630465

  7. A Bayesian algorithm for detecting differentially expressed proteins and its application in breast cancer research

    NASA Astrophysics Data System (ADS)

    Santra, Tapesh; Delatola, Eleni Ioanna

    2016-07-01

    Presence of considerable noise and missing data points make analysis of mass-spectrometry (MS) based proteomic data a challenging task. The missing values in MS data are caused by the inability of MS machines to reliably detect proteins whose abundances fall below the detection limit. We developed a Bayesian algorithm that exploits this knowledge and uses missing data points as a complementary source of information to the observed protein intensities in order to find differentially expressed proteins by analysing MS based proteomic data. We compared its accuracy with many other methods using several simulated datasets. It consistently outperformed other methods. We then used it to analyse proteomic screens of a breast cancer (BC) patient cohort. It revealed large differences between the proteomic landscapes of triple negative and Luminal A, which are the most and least aggressive types of BC. Unexpectedly, majority of these differences could be attributed to the direct transcriptional activity of only seven transcription factors some of which are known to be inactive in triple negative BC. We also identified two new proteins which significantly correlated with the survival of BC patients, and therefore may have potential diagnostic/prognostic values.

  8. Sensitivity and specificity for detecting basal cell carcinomas in Mohs excisions with confocal fluorescence mosaicing microscopy

    NASA Astrophysics Data System (ADS)

    Gareau, Daniel S.; Karen, Julie K.; Dusza, Stephen W.; Tudisco, Marie; Nehal, Kishwer S.; Rajadhyaksha, Milind

    2009-05-01

    Recent studies have demonstrated the ability of confocal fluorescence mosaicing microscopy to rapidly detect basal cell carcinomas (BCCs) directly in thick and fresh Mohs surgical excisions. Mosaics of confocal images display large areas of tissue with high resolution and magnification equivalent to 2×, which is the standard magnification when examining pathology. Comparison of mosaics to Mohs frozen histopathology was shown to be excellent for all types of BCCs. However, comparisons in the previous studies were visual and qualitative. In this work, we report the results of a semiquantitative preclinical study in which 45 confocal mosaics are blindly evaluated for the presence (or absence) of BCC tumor. The evaluations are made by two clinicians: a senior Mohs surgeon with prior expertise in interpreting confocal images, and a novice Mohs fellow with limited experience. The blinded evaluation is compared to the gold standard of frozen histopathology. BCCs are detected with an overall sensitivity of 96.6%, specificity of 89.2%, positive predictive value of 93.0%, and negative predictive value of 94.7%. The results demonstrate the potential clinical utility of confocal mosaicing microscopy toward rapid surgical pathology at the bedside to expedite and guide surgery.

  9. Whole body MRI: Improved Lesion Detection and Characterization With Diffusion Weighted Techniques

    PubMed Central

    Attariwala, Rajpaul; Picker, Wayne

    2013-01-01

    Diffusion-weighted imaging (DWI) is an established functional imaging technique that interrogates the delicate balance of water movement at the cellular level. Technological advances enable this technique to be applied to whole-body MRI. Theory, b-value selection, common artifacts and target to background for optimized viewing will be reviewed for applications in the neck, chest, abdomen, and pelvis. Whole-body imaging with DWI allows novel applications of MRI to aid in evaluation of conditions such as multiple myeloma, lymphoma, and skeletal metastases, while the quantitative nature of this technique permits evaluation of response to therapy. Persisting signal at high b-values from restricted hypercellular tissue and viscous fluid also permits applications of DWI beyond oncologic imaging. DWI, when used in conjunction with routine imaging, can assist in detecting hemorrhagic degradation products, infection/abscess, and inflammation in colitis, while aiding with discrimination of free fluid and empyema, while limiting the need for intravenous contrast. DWI in conjunction with routine anatomic images provides a platform to improve lesion detection and characterization with findings rivaling other combined anatomic and functional imaging techniques, with the added benefit of no ionizing radiation. PMID:23960006

  10. Ultrasensitive Biosensor for the Detection of Vibrio cholerae DNA with Polystyrene-co-acrylic Acid Composite Nanospheres

    NASA Astrophysics Data System (ADS)

    Rahman, Mahbubur; Heng, Lee Yook; Futra, Dedi; Ling, Tan Ling

    2017-08-01

    An ultrasensitive electrochemical biosensor for the determination of pathogenic Vibrio cholerae ( V. cholerae) DNA was developed based on polystyrene-co-acrylic acid (PSA) latex nanospheres-gold nanoparticles composite (PSA-AuNPs) DNA carrier matrix. Differential pulse voltammetry (DPV) using an electroactive anthraquninone oligonucleotide label was used for measuring the biosensor response. Loading of gold nanoparticles (AuNPs) on the DNA-latex particle electrode has significantly amplified the faradaic current of DNA hybridisation. Together with the use of a reported probe, the biosensor has demonstrated high sensitivity. The DNA biosensor yielded a reproducible and wide linear response range to target DNA from 1.0 × 10-21 to 1.0 × 10-8 M (relative standard deviation, RSD = 4.5%, n = 5) with a limit of detection (LOD) of 1.0 × 10-21 M ( R 2 = 0.99). The biosensor obtained satisfactory recovery values between 91 and 109% ( n = 3) for the detection of V. cholerae DNA in spiked samples and could be reused for six consecutive DNA assays with a repeatability RSD value of 5% ( n = 5). The electrochemical biosensor response was stable and maintainable at 95% of its original response up to 58 days of storage period.

  11. Optimized determination method for trans-10-hydroxy-2-decenoic acid content in royal jelly by high-performance liquid chromatography with an internal standard.

    PubMed

    Zhou, Jinhui; Xue, Xiaofeng; Li, Yi; Zhang, Jinzhen; Zhao, Jing

    2007-01-01

    An optimized reversed-phase high-performance liquid chromatography method was developed to detect the trans-10-hydroxy-2-decenoic acid (10-HDA) content in royal jelly cream and lyophilized powder. The sample was extracted using absolute ethanol. Chromatographic separation of 10-HDA and methyl 4-hydroxybenzoate as the internal standard was performed on a Nova-pak C18 column. The average recoveries were 95.0-99.2% (n = 5) with relative standard deviation (RSD) values of 1.3-2.1% for royal jelly cream and 98.0-100.0% (n = 5) with RSD values of 1.6-3.0% for lyophilized powder, respectively. The limits of detection and quantitation were 0.5 and 1.5 mg/kg, respectively, for both royal jelly cream and lyophilized powder. The method was validated for the determination of practical royal jelly products. The concentration of 10-HDA ranged from 1.26 to 2.21% for pure royal jelly cream samples and 3.01 to 6.19% for royal jelly lyophilized powder samples. For 30 royal jelly products, the 10-HDA content varied from not detectable to 0.98%.

  12. Novel highly-performing immunosensor-based strategy for ochratoxin A detection in wine samples.

    PubMed

    Prieto-Simón, Beatriz; Campàs, Mònica; Marty, Jean-Louis; Noguer, Thierry

    2008-02-28

    The increasing concern about ochratoxin A (OTA) contamination of different food and feedstuffs demands high-performing detection techniques for quality assessment. Two indirect competitive enzyme-linked immunosorbent assay (ELISA) strategies were investigated for the development of OTA electrochemical immunosensors based on different OTA immobilisation procedures. Immunosensors based on avidin/biotin-OTA showed enhanced performance characteristics compared to those based on the adsorption of bovine serum albumin (BSA)-OTA conjugate. Performance of polyclonal (PAb) and monoclonal (MAb) antibodies against OTA was compared, showing at least one-order of magnitude lower IC(50) values when working with MAb. Alkaline phosphatase (ALP)- and horseradish peroxidase (HRP)-labelled secondary antibodies were evaluated. Both conjugates led to similar results when working with OTA standard solutions in buffer. However, whereas electroactive interferences present in spiked wine samples did not affect HRP-labelled immunosensors (4% slope deviation), they were likely oxidised at 0.225 V versus Ag/AgCl, the working potential for ALP-labelled immunosensors (25% slope deviation). Considering 80% of antibody binding as the limit of detection, values of 0.7 and 0.3 ng/mL for HRP- and ALP-labelled immunosensors respectively, validate these immunosensors as useful screening tools to assess OTA levels in wine.

  13. Constraints on water vapor and sulfur dioxide at Ceres: Exploiting the sensitivity of the Hubble Space Telescope

    NASA Astrophysics Data System (ADS)

    Roth, Lorenz

    2018-05-01

    Far-ultraviolet observations of dwarf-planet (1) Ceres were obtained on several occasions in 2015 and 2016 by the Cosmic Origins Spectrograph (COS) and the Space Telescope Imaging Spectrograph (STIS), both on board the Hubble Space Telescope (HST). We report a search for neutral gas emissions at hydrogen, oxygen and sulfur lines around Ceres from a potential teneous exosphere. No detectable exosphere emissions are present in any of the analyzed HST observations. We apply analytical models to relate the derived upper limits for the atomic species to a water exosphere (for H and O) and a sulfur dioxide exosphere (for S and O), respectively. The H and O upper limits constrain the H2O production rate at the surface to (2 - 4) ×1026 molecules s-1 or lower, similar to or slightly larger than previous detections and upper limits. With low fluxes of energetic protons measured in the solar wind prior to the HST observations and the obtained non-detections, an assessment of the recently suggested sputter-generated water exosphere during solar energetic particle events is not possible. Investigating a sulfur dioxide-based exosphere, we find that the O and S upper limits constrain the SO2 density at the surface to values ∼ 1010 times lower than the equilibrium vapor pressure density. This result implies that SO2 is not present on Ceres' sunlit surface, contrary to previous findings in HST ultraviolet reflectance spectra but in agreement with the absence of SO2 infrared spectral features as observed by the Dawn spacecraft.

  14. [Alanine aminotransferase (ALAT, GPT): a reevaluation of exclusion limits for blood donors].

    PubMed

    Grunenberg, R; Banik, N; Krüger, J

    1995-06-01

    The screening policy of alanine aminotransferase (ALT) testing in blood donors was reassessed. The cutoff value for ALT levels according to German guidelines has always been controversial. In this study the activity and distribution of ALT in a blood donor population were reevaluated and new exclusion levels were defined. 5,706 blood donors were tested for ALT activities with the Reflotron system at 37 degrees C. Donors with ALT levels > 51 IU/l were deferred, a detailed physical examination and additional serologic and biochemical testing were done. ALT values of blood donors were transformed in logarithmic values in order to get a Gaussian distribution. The mean transformed value +/- SD was calculated with 1.24 +/- 0.14 for females and with 1.35 +/- 0.16 for males, corresponding to mean values of ALT activity of 17.6 and 22.5 IU/l, respectively. Exclusion levels of > 33.4 IU/l for female and > 46.7 IU/l for male blood donors (geometric mean +2.0 SD) predict a loss of donations of 2.8 and 2.7%, respectively, cutoff values of > 39.1 or > 56.1 IU/l (geometric mean +2.5 SD) a loss of 1.8 and 1.4%, respectively. The most likely causes of elevated ALT levels in 166 of our donors included daily alcohol use (82), infections with/without antibiotic medication (29), therapy with hepatotoxic drugs (8), strenuous exercises (5), bodybuilding complemented by anabolic steroids (2), acute infections with HCV (1), HBV (1) and CMV (1), alcohol/drug abuse and detection of HCV antibodies (1). ALT screening is still considered a useful indicator of risk donors despite its nonspecificity and limited predictive value. The selection of the appropriate cutoff value has always been disputed. The present exclusion level of > 45 IU/l (25 degrees C), analogous to > 81.8 IU/l (37 degrees C), does not even take into account such a variable as sex. The cutoff value above 4.5 SD of the geometric mean for females and above 3.5 SD for males seems to be of limited medical and practical value.

  15. Functional DNA quantification guides accurate next-generation sequencing mutation detection in formalin-fixed, paraffin-embedded tumor biopsies

    PubMed Central

    2013-01-01

    The formalin-fixed, paraffin-embedded (FFPE) biopsy is a challenging sample for molecular assays such as targeted next-generation sequencing (NGS). We compared three methods for FFPE DNA quantification, including a novel PCR assay (‘QFI-PCR’) that measures the absolute copy number of amplifiable DNA, across 165 residual clinical specimens. The results reveal the limitations of commonly used approaches, and demonstrate the value of an integrated workflow using QFI-PCR to improve the accuracy of NGS mutation detection and guide changes in input that can rescue low quality FFPE DNA. These findings address a growing need for improved quality measures in NGS-based patient testing. PMID:24001039

  16. Higher Throughput Calorimetry: Opportunities, Approaches and Challenges

    PubMed Central

    Recht, Michael I.; Coyle, Joseph E.; Bruce, Richard H.

    2010-01-01

    Higher throughput thermodynamic measurements can provide value in structure-based drug discovery during fragment screening, hit validation, and lead optimization. Enthalpy can be used to detect and characterize ligand binding, and changes that affect the interaction of protein and ligand can sometimes be detected more readily from changes in the enthalpy of binding than from the corresponding free-energy changes or from protein-ligand structures. Newer, higher throughput calorimeters are being incorporated into the drug discovery process. Improvements in titration calorimeters come from extensions of a mature technology and face limitations in scaling. Conversely, array calorimetry, an emerging technology, shows promise for substantial improvements in throughput and material utilization, but improved sensitivity is needed. PMID:20888754

  17. Comet encke: radar detection of nucleus.

    PubMed

    Kamoun, P G; Campbell, D B; Ostro, S J; Pettengill, G H; Shapiro, I I

    1982-04-16

    The nucleus of the periodic comet Encke was detected in November 1980 with the Arecibo Observatory's radar system (wavelength, 12.6 centimeters). The echoes in the one sense of circular polarization received imply a radar cross section of 1.1 +/- 0.7 square kilometers. The estimated bandwidth of these echoes combined with an estimate of the rotation vector of Encke yields a radius for the nucleus of l.5(+2.3)(-1.0) kilometers. The uncertainties given are dependent primarily on the range of models considered for the comet and for the manner in which its nucleus backscatters radio waves. Should this range prove inadequate, the true value of the radius of the nucleus might lie outside the limits given.

  18. Diagnostic accuracy of urinary creatinine concentration in the estimation of differential renal function in patients with obstructive uropathy.

    PubMed

    Al-Hunayan, A; Al-Ateeqi, A; Kehinde, E O; Thalib, L; Loutfi, I; Mojiminiyi, O A

    2008-01-01

    To determine the diagnostic accuracy of spot urine creatinine concentration (UCC) as a new test for the evaluation of differential renal function in obstructed kidneys (DRF(ok)) drained by percutaneous nephrostomy tube (PCNT). In patients with obstructed kidneys drained by PCNT, DRF(ok) was derived from UCC by comparing the value of UCC in the obstructed kidney to the value in the contralateral kidney, and was derived from dimercaptosuccinic acid (DMSA) renal scans and creatinine clearance (CCr) using standard methods. Subsequently, the results of UCC were compared to the results of DMSA and CCr. 61 patients were enrolled. Bland-Altman plots to compare DMSA and UCC showed that the upper limit of agreement was 14.8% (95% CI 10.7-18.5) and the lower limit was -19.9% (95% CI -23.8 to -16.1). The sensitivity and specificity of detecting DMSA DRF(ok) < or = 35% using UCC was 85.2 and 91.2%, respectively. When UCC was compared to CCr, Bland-Altman tests gave an upper limit of agreement of 10.4% (95% CI 7.9-12.8) and a lower limit of agreement of -11.3% (95% CI -13.8 to -8.9). UCC is accurate in the estimation of DRF(ok) drained by PCNT. 2008 S. Karger AG, Basel

  19. Significance of CEA and VEGF as Diagnostic Markers of Colorectal Cancer in Lebanese Patients.

    PubMed

    Dbouk, Hashem A; Tawil, Ayman; Nasr, Fahd; Kandakarjian, Loucine; Abou-Merhi, Raghida

    2007-11-08

    Carcinoembryonic antigen and vascular endothelial growth factors are among the most important prognostic markers of colorectal cancer. Testing for these markers independently has been of limited value in screening for this tumor. The aim of this study is to determine the importance of simultaneous blood CEA and VEGF level determinations in diagnosis of colorectal cancer. Thirty-six patients diagnosed with colorectal cancer along with eight healthy controls were tested by ELISA for CEA and VEGF levels in serum and plasma, respectively. The positive predictive value of these markers was 95.4% for CEA and 89.5% for VEGF, and for combined CEA and VEGF was also high at 88%. Combined CEA and VEGF blood level assay constitutes a useful panel in detecting patients with colorectal cancer. Positive results allow selection of a subgroup of patients with a high tumor risk; therefore, such tests comprise valuable tumor diagnostic tests to add to current detection methods.

  20. Determination of 241Am in Urine Using Sector Field Inductively Coupled Plasma Mass Spectrometry (SF-ICP-MS)

    PubMed Central

    Xiao, Ge; Saunders, David; Jones, Robert L.; Caldwell, Kathleen L.

    2016-01-01

    Quantification of 241Am in urine at low levels is important for assessment of individuals’ or populations’ accidental, environmental, or terrorism-related internal contamination, but no convenient, precise method has been established to rapidly determine these low levels. Here we report a new analytical method to measure 241Am as developed and validated at the Centers for Disease Control and Prevention (CDC) by means of the selective retention of Am from urine directly on DGA resin, followed by SF-ICP-MS detection. The method provides rapid results with a Limit of Detection (LOD) of 0.22 pg/L (0.028 Bq/L), which is lower than 1/3 of the C/P CDG for 241Am at 5 days post-exposure. The results obtained by this method closely agree with CDC values as measured by Liquid Scintillation Counting, and with National Institute of Standards Technology (NIST) Certified Reference Materials (CRM) target values. PMID:27375308

  1. Determination of 241Am in Urine Using Sector Field Inductively Coupled Plasma Mass Spectrometry (SF-ICP-MS).

    PubMed

    Xiao, Ge; Saunders, David; Jones, Robert L; Caldwell, Kathleen L

    2016-07-01

    Quantification of 241 Am in urine at low levels is important for assessment of individuals' or populations' accidental, environmental, or terrorism-related internal contamination, but no convenient, precise method has been established to rapidly determine these low levels. Here we report a new analytical method to measure 241 Am as developed and validated at the Centers for Disease Control and Prevention (CDC) by means of the selective retention of Am from urine directly on DGA resin, followed by SF-ICP-MS detection. The method provides rapid results with a Limit of Detection (LOD) of 0.22 pg/L (0.028 Bq/L), which is lower than 1/3 of the C/P CDG for 241 Am at 5 days post-exposure. The results obtained by this method closely agree with CDC values as measured by Liquid Scintillation Counting, and with National Institute of Standards Technology (NIST) Certified Reference Materials (CRM) target values.

  2. Highly sensitive MoS2 photodetectors with graphene contacts

    NASA Astrophysics Data System (ADS)

    Han, Peize; St. Marie, Luke; Wang, Qing X.; Quirk, Nicholas; El Fatimy, Abdel; Ishigami, Masahiro; Barbara, Paola

    2018-05-01

    Two-dimensional materials such as graphene and transition metal dichalcogenides (TMDs) are ideal candidates to create ultra-thin electronics suitable for flexible substrates. Although optoelectronic devices based on TMDs have demonstrated remarkable performance, scalability is still a significant issue. Most devices are created using techniques that are not suitable for mass production, such as mechanical exfoliation of monolayer flakes and patterning by electron-beam lithography. Here we show that large-area MoS2 grown by chemical vapor deposition and patterned by photolithography yields highly sensitive photodetectors, with record shot-noise-limited detectivities of 8.7 × 1014 Jones in ambient condition and even higher when sealed with a protective layer. These detectivity values are higher than the highest values reported for photodetectors based on exfoliated MoS2. We study MoS2 devices with gold electrodes and graphene electrodes. The devices with graphene electrodes have a tunable band alignment and are especially attractive for scalable ultra-thin flexible optoelectronics.

  3. Highly sensitive MoS2 photodetectors with graphene contacts.

    PubMed

    Han, Peize; St Marie, Luke; Wang, Qing X; Quirk, Nicholas; El Fatimy, Abdel; Ishigami, Masahiro; Barbara, Paola

    2018-05-18

    Two-dimensional materials such as graphene and transition metal dichalcogenides (TMDs) are ideal candidates to create ultra-thin electronics suitable for flexible substrates. Although optoelectronic devices based on TMDs have demonstrated remarkable performance, scalability is still a significant issue. Most devices are created using techniques that are not suitable for mass production, such as mechanical exfoliation of monolayer flakes and patterning by electron-beam lithography. Here we show that large-area MoS 2 grown by chemical vapor deposition and patterned by photolithography yields highly sensitive photodetectors, with record shot-noise-limited detectivities of 8.7 × 10 14 Jones in ambient condition and even higher when sealed with a protective layer. These detectivity values are higher than the highest values reported for photodetectors based on exfoliated MoS 2 . We study MoS 2 devices with gold electrodes and graphene electrodes. The devices with graphene electrodes have a tunable band alignment and are especially attractive for scalable ultra-thin flexible optoelectronics.

  4. The application of LANDSAT-1 imagery for monitoring strip mines in the new river watershed in northeast Tennessee, part 2

    NASA Technical Reports Server (NTRS)

    Shahrokhi, F. (Principal Investigator); Sharber, L. A.

    1977-01-01

    The author has identified the following significant results. LANDSAT imagery and supplementary aircraft photography of the New River drainage basin were subjected to a multilevel analysis using conventional photointerpretation methods, densitometric techniques, multispectral analysis, and statistical tests to determine the accuracy of LANDSAT-1 imagery for measuring strip mines of common size. The LANDSAT areas were compared with low altitude measurements. The average accuracy over all the mined land sample areas mapped from LANDSAT-1 was 90%. The discrimination of strip mine subcategories is somewhat limited on LANDSAT imagery. A mine site, whether active or inactive, can be inferred by lack of vegetation, by shape, or image texture. Mine ponds are difficult or impossible to detect because of their small size and turbidity. Unless bordered and contrasted with vegetation, haulage roads are impossible to delineate. Preparation plants and refuge areas are not detectable. Density slicing of LANDSAT band 7 proved most useful in the detection of reclamation progress within the mined areas. For most state requirements for year-round monitoring of surface mined land, LANDSAT is of limited value. However, for periodic updating of regional surface maps, LANDSAT may provide sufficient accuracies for some users.

  5. Multivariate curve-resolution analysis of pesticides in water samples from liquid chromatographic-diode array data.

    PubMed

    Maggio, Rubén M; Damiani, Patricia C; Olivieri, Alejandro C

    2011-01-30

    Liquid chromatographic-diode array detection data recorded for aqueous mixtures of 11 pesticides show the combined presence of strongly coeluting peaks, distortions in the time dimension between experimental runs, and the presence of potential interferents not modeled by the calibration phase in certain test samples. Due to the complexity of these phenomena, data were processed by a second-order multivariate algorithm based on multivariate curve resolution and alternating least-squares, which allows one to successfully model both the spectral and retention time behavior for all sample constituents. This led to the accurate quantitation of all analytes in a set of validation samples: aldicarb sulfoxide, oxamyl, aldicarb sulfone, methomyl, 3-hydroxy-carbofuran, aldicarb, propoxur, carbofuran, carbaryl, 1-naphthol and methiocarb. Limits of detection in the range 0.1-2 μg mL(-1) were obtained. Additionally, the second-order advantage for several analytes was achieved in samples containing several uncalibrated interferences. The limits of detection for all analytes were decreased by solid phase pre-concentration to values compatible to those officially recommended, i.e., in the order of 5 ng mL(-1). Copyright © 2010 Elsevier B.V. All rights reserved.

  6. Rapid detection of porcine circovirus type 2 using a TaqMan-based real-time PCR.

    PubMed

    Zhao, Kai; Han, Fangting; Zou, Yong; Zhu, Lianlong; Li, Chunhua; Xu, Yan; Zhang, Chunling; Tan, Furong; Wang, Jinbin; Tao, Shiru; He, Xizhong; Zhou, Zongqing; Tang, Xueming

    2010-12-31

    Porcine circovirus type 2 (PCV2) and the associated disease postweaning multisystemic wasting syndrome (PMWS) have caused heavy losses in global agriculture in recent decades. Rapid detection of PCV2 is very important for the effective prophylaxis and treatment of PMWS. To establish a sensitive, specific assay for the detection and quantitation of PCV2, we designed and synthesized specific primers and a probe in the open reading frame 2. The assay had a wide dynamic range with excellent linearity and reliable reproducibility, and detected between 102 and 1010 copies of the genomic DNA per reaction. The coefficient of variation for Ct values varied from 0.59% to 1.05% in the same assay and from 1.9% to 4.2% in 10 different assays. The assay did not cross-react with porcine circovirus type 1, porcine reproductive and respiratory, porcine epidemic diarrhea, transmissible gastroenteritis of pigs and rotavirus. The limits of detection and quantitation were 10 and 100 copies, respectively. Using the established real-time PCR system, 39 of the 40 samples we tested were detected as positive.

  7. Detection of nitric oxide in the dark cloud L134N

    NASA Technical Reports Server (NTRS)

    Mcgonagle, D.; Irvine, W. M.; Minh, Y. C.; Ziurys, L. M.

    1990-01-01

    The first detection of interstellar nitric oxide (NO) in a cold dark cloud, L134N is reported. Nitric oxide was observed by means of its two 2 Pi 1/2, J = 3/2 - 1/2, rotational transitions at 150.2 and 150.5 GHz, which occur because of Lambda-doubling. The inferred column density for L134N is about 5 x 10 to the 14th/sq cm toward the SO peak in that cloud. This value corresponds to a fractional abundance relative to molecular hydrogen of about 6 x 10 to the -8th and is in good agreement with predictions of quiescent cloud ion-molecule chemistry. NO was not detected toward the dark cloud TMC-1 at an upper limit of 3 x 10 to the -8th or less.

  8. Engineering surface states of carbon dots to achieve controllable luminescence for solid-luminescent composites and sensitive Be2+ detection

    PubMed Central

    Li, Xiaoming; Zhang, Shengli; Kulinich, Sergei A.; Liu, Yanli; Zeng, Haibo

    2014-01-01

    Luminescent carbon dots (L-CDs) with high quantum yield value (44.7%) and controllable emission wavelengths were prepared via a facile hydrothermal method. Importantly, the surface states of the materials could be engineered so that their photoluminescence was either excitation-dependent or distinctly independent. This was achieved by changing the density of amino-groups on the L-CD surface. The above materials were successfully used to prepare multicolor L-CDs/polymer composites, which exhibited blue, green, and even white luminescence. In addition, the excellent excitation-independent luminescence of L-CDs prepared at low temperature was tested for detecting various metal ions. As an example, the detection limit of toxic Be2+ ions, tested for the first time, was as low as 23 μM.

  9. New calorimeters for space experiments: physics requirements and technological challenges

    NASA Astrophysics Data System (ADS)

    Marrocchesi, Pier Simone

    2015-07-01

    Direct measurements of charged cosmic radiation with instruments in Low Earth Orbit (LEO), or flying on balloons above the atmosphere, require the identification of the incident particle, the measurement of its energy and possibly the determination of its sign-of-charge. The latter information can be provided by a magnetic spectrometer together with a measurement of momentum. However, magnetic deflection in space experiments is at present limited to values of the Maximum Detectable Rigidity (MDR) hardly exceeding a few TV. Advanced calorimetric techniques are, at present, the only way to measure charged and neutral radiation at higher energies in the multi-TeV range. Despite their mass limitation, calorimeters may achieve a large geometric factor and provide an adequate proton background rejection factor, taking advantage of a fine granularity and imaging capabilities. In this lecture, after a brief introduction on electromagnetic and hadronic calorimetry, an innovative approach to the design of a space-borne, large acceptance, homogeneous calorimeter for the detection of high energy cosmic rays will be described.

  10. Synchronous fluorescence based biosensor for albumin determination by cooperative binding of fluorescence probe in a supra-biomolecular host-protein assembly.

    PubMed

    Patra, Digambara

    2010-01-15

    A synchronous fluorescence probe based biosensor for estimation of albumin with high sensitivity and selectivity was developed. Unlike conventional fluorescence emission or excitation spectral measurements, synchronous fluorescence measurement offered exclusively a new synchronous fluorescence peak in the shorter wavelength range upon binding of chrysene with protein making it an easy identification tool for albumin determination. The cooperative binding of a fluorescence probe, chrysene, in a supramolecular host-protein assembly during various albumin assessments was investigated. The presence of supramolecular host molecules such as beta-cyclodextrin, curucurbit[6]uril or curucurbit[7]uril have little influence on sensitivity or limit of detection during albumin determination but reduced dramatically interference from various coexisting metal ion quenchers/enhancers. Using the present method the limit of detection for BSA and gamma-Globulin was found to be 0.005 microM which is more sensitive than reported values. Copyright 2009 Elsevier B.V. All rights reserved.

  11. Nitrate and Nitrite Determination in Gunshot Residue Samples by Capillary Electrophoresis in Acidic Run Buffer.

    PubMed

    Erol, Özge Ö; Erdoğan, Behice Y; Onar, Atiye N

    2017-03-01

    Simultaneous determination of nitrate and nitrite in gunshot residue has been conducted by capillary electrophoresis using an acidic run buffer (pH 3.5). In previously developed capillary electrophoretic methods, alkaline pH separation buffers were used where nitrite and nitrate possess similar electrophoretic mobility. In this study, the electroosmotic flow has been reversed by using low pH running buffer without any additives. As a result of reversing the electroosmotic flow, very fast analysis has been actualized, well-defined and separated ion peaks emerge in less than 4 min. Besides, the limit of detection was improved by employing large volume sample stacking. Limit of detection values were 6.7 and 4.3 μM for nitrate and nitrite, respectively. In traditional procedure, mechanical agitation is employed for extraction, while in this work the extraction efficiency of ultrasound mixing for 30 min was found sufficient. The proposed method was successfully applied to authentic gunshot residue samples. © 2016 American Academy of Forensic Sciences.

  12. Determination of artificial sweeteners in beverages with green mobile phases and high temperature liquid chromatography-tandem mass spectrometry.

    PubMed

    Ordoñez, Edgar Y; Rodil, Rosario; Quintana, José Benito; Cela, Rafael

    2015-02-15

    A new analytical procedure involving the use of water and a low percentage of ethanol combined to high temperature liquid chromatography-tandem mass spectrometry has been developed for the determination of nine high-intensity sweeteners in a variety of drink samples. The method permitted the analysis in 23min (including column reequilibration) and consuming only 0.85mL of a green organic solvent (ethanol). This methodology provided limits of detection (after 50-fold dilution) in the 0.05-10mg/L range, with recoveries (obtained from five different types of beverages) being in the 86-110% range and relative standard deviation values lower than 12%. Finally, the method was applied to 25 different samples purchased in Spain, where acesulfame and sucralose were the most frequently detected analytes (>50% of the samples) and cyclamate was found over the legislation limit set by the European Union in a sample and at the regulation boundary in three others. Copyright © 2014 Elsevier Ltd. All rights reserved.

  13. Photometric and fluorometric continuous kinetic assay of acid phosphatases with new substrates possessing longwave absorption and emission maxima.

    PubMed

    Koller, E; Wolfbeis, O S

    1984-11-15

    A direct and continuous kinetic method for the photometric and fluorometric determination of various acid phosphatases is described. It is based on new coumarin-derived phosphates, which after enzymatic hydrolysis undergo dissociation to form intensely colored and strongly fluorescent phenolate anions. The latter have absorption maxima ranging from 385 to 505 nm, and fluorescence maxima between 470 and 595 nm. The new substrates were compared with respect to their rate of enzymatic hydrolysis, optimum pH, and detection limits of acid phosphatase from potato and wheat germ. Detection limits of 0.001 unit/ml were found by photometry, and as low as 0.00006 unit/ml by fluorometry. The principal advantages of the new substrates over existing ones are longwave absorptions and emissions, large Stokes shifts, and the low pKa values of the corresponding phenols, thus allowing a direct and continuous assay of acid phosphatase even in weakly acidic solutions.

  14. DIFFUSION-WEIGHTED IMAGING OF THE LIVER: TECHNIQUES AND APPLICATIONS

    PubMed Central

    Lewis, Sara; Dyvorne, Hadrien; Cui, Yong; Taouli, Bachir

    2014-01-01

    SYNOPSIS Diffusion weighted MRI (DWI) is a technique that assesses the cellularity, tortuosity of the extracellular/extravascular space and cell membrane density based upon differences in water proton mobility in tissues. The strength of the diffusion weighting is reflected by the b-value. DWI using several b-values enables quantification of the apparent diffusion coefficient (ADC). DWI is increasingly employed in liver imaging for multiple reasons: it can add useful qualitative and quantitative information to conventional imaging sequences, it is acquired relatively quickly, it is easily incorporated into existing clinical protocols, and it is a non-contrast technique. DWI is useful for focal liver lesion detection and characterization, for the assessment of post-treatment tumor response and for evaluation of diffuse liver disease. ADC quantification can be used to characterize lesions as cystic/necrotic or solid and for predicting tumor response to therapy. Advanced diffusion methods such as IVIM (intravoxel incoherent motion) may have potential for detection, staging and evaluation of the progression of liver fibrosis and for liver lesion characterization. The lack of standardization of DWI technique including choice of b-values and sequence parameters has somewhat limited its widespread adoption. PMID:25086935

  15. New directions in diagnostic evaluation of insect allergy.

    PubMed

    Golden, David B K

    2014-08-01

    Diagnosis of insect sting allergy and prediction of risk of sting anaphylaxis are often difficult because tests for venom-specific IgE antibodies have a limited positive predictive value and do not reliably predict the severity of sting reactions. Component-resolved diagnosis using recombinant venom allergens has shown promise in improving the specificity of diagnostic testing for insect sting allergy. Basophil activation tests have been explored as more sensitive assays for identification of patients with insect allergy and for prediction of clinical outcomes. Measurement of mast cell mediators reflects the underlying risk for more severe reactions and limited clinical response to treatment. Measurement of IgE to recombinant venom allergens can distinguish cross-sensitization from dual sensitization to honeybee and vespid venoms, thus helping to limit venom immunotherapy to a single venom instead of multiple venoms in many patients. Basophil activation tests can detect venom allergy in patients who show no detectable venom-specific IgE in standard diagnostic tests and can predict increased risk of systemic reactions to venom immunotherapy, and to stings during and after stopping venom immunotherapy. The risk of severe or fatal anaphylaxis to stings can also be predicted by measurement of baseline serum tryptase or other mast cell mediators.

  16. Material Limitations on the Detection Limit in Refractometry

    PubMed Central

    Skafte-Pedersen, Peder; Nunes, Pedro S.; Xiao, Sanshui; Mortensen, Niels Asger

    2009-01-01

    We discuss the detection limit for refractometric sensors relying on high-Q optical cavities and show that the ultimate classical detection limit is given by min {Δn} ≳ η, with n + iη being the complex refractive index of the material under refractometric investigation. Taking finite Q factors and filling fractions into account, the detection limit declines. As an example we discuss the fundamental limits of silicon-based high-Q resonators, such as photonic crystal resonators, for sensing in a bio-liquid environment, such as a water buffer. In the transparency window (λ ≳ 1100 nm) of silicon the detection limit becomes almost independent on the filling fraction, while in the visible, the detection limit depends strongly on the filling fraction because the silicon absorbs strongly. PMID:22291513

  17. GFAAS determination of selenium in infant formulas using a microwave digestion method.

    PubMed

    Alegria, A; Barbera, R; Farré, R; Moreno, A

    1994-01-01

    A method for determining the selenium content of infant formulas is proposed. It includes wet digestion with nitric acid and hydrogen peroxide in medium pressure teflon bombs in a microwave oven and determination by graphite furnace atomic absorption spectrometry (GFAAS). The absence of interferences is checked. Values obtained for the limit of detection (19.4 ng/g), precision (RSD = 2.2%) and accuracy by analysis of a reference material show that the method is reliable.

  18. Median nitrate concentrations in groundwater in the New Jersey Highlands Region estimated using regression models and land-surface characteristics

    USGS Publications Warehouse

    Baker, Ronald J.; Chepiga, Mary M.; Cauller, Stephen J.

    2015-01-01

    The Kaplan-Meier method of estimating summary statistics from left-censored data was applied in order to include nondetects (left-censored data) in median nitrate-concentration calculations. Median concentrations also were determined using three alternative methods of handling nondetects. Treatment of the 23 percent of samples that were nondetects had little effect on estimated median nitrate concentrations because method detection limits were mostly less than median values.

  19. Real-time calculation of a limiting form of the Renyi entropy applied to detection of subtle changes in scattering architecture

    PubMed Central

    Hughes, M. S.; McCarthy, J. E.; Wickerhauser, M. V.; Marsh, J. N.; Arbeit, J. M.; Fuhrhop, R. W.; Wallace, K. D.; Thomas, T.; Smith, J.; Agyem, K.; Lanza, G. M.; Wickline, S. A.

    2009-01-01

    Previously a new method for ultrasound signal characterization using entropy Hf was reported, and it was demonstrated that in certain settings, further improvements in signal characterization could be obtained by generalizing to Renyi entropy-based signal characterization If(r) with values of r near 2 (specifically r=1.99) [M. S. Hughes et al., J. Acoust. Soc. Am. 125, 3141–3145 (2009)]. It was speculated that further improvements in sensitivity might be realized at the limit r→2. At that time, such investigation was not feasible due to excessive computational time required to calculate If(r) near this limit. In this paper, an asymptotic expression for the limiting behavior of If(r) as r→2 is derived and used to present results analogous to those obtained with If(1.99). Moreover, the limiting form If,∞ is computable directly from the experimentally measured waveform f(t) by an algorithm that is suitable for real-time calculation and implementation. PMID:19894818

  20. Sensitive determination of D-lactic acid and L-lactic acid in urine by high-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Henry, H; Marmy Conus, N; Steenhout, P; Béguin, A; Boulat, O

    2012-04-01

    D-lactic acid in urine originates mainly from bacterial production in the intestinal tract. Increased D-lactate excretion as observed in patients affected by short bowel syndrome or necrotizing enterocolitis reflects D-lactic overproduction. Therefore, there is a need for a reliable and sensitive method able to detect D-lactic acid even at subclinical elevation levels. A new and highly sensitive method for the simultaneous determination of L- and D-lactic acid by a two-step procedure has been developed. This method is based on the concentration of lactic acid enantiomers from urine by supported liquid extraction followed by high-performance liquid chromatography-tandem mass spectrometry. The separation was achieved by the use of an Astec Chirobiotic™ R chiral column under isocratic conditions. The calibration curves were linear over the ranges of 2-400 and 0.5-100 µmol/L respectively for L- and D-lactic acid. The limit of detection of D-lactic acid was 0.125 µmol/L and its limit of quantification was 0.5 µmol/L. The overall accuracy and precision were well within 10% of the nominal values. The developed method is suitable for production of reference values in children and could be applied for accurate routine analysis. Copyright © 2011 John Wiley & Sons, Ltd.

Top