METHODS OF DEALING WITH VALUES BELOW THE LIMIT OF DETECTION USING SAS
Due to limitations of chemical analysis procedures, small values cannot be precisely measured. These values are said to be below the limit of detection (LOD). In statistical analyses, these values are often censored and substituted with a constant value, such as half the LOD,...
Flavoring exposure in food manufacturing.
Curwin, Brian D; Deddens, Jim A; McKernan, Lauralynn T
2015-05-01
Flavorings are substances that alter or enhance the taste of food. Workers in the food-manufacturing industry, where flavorings are added to many products, may be exposed to any number of flavoring compounds. Although thousands of flavoring substances are in use, little is known about most of these in terms of worker health effects, and few have occupational exposure guidelines. Exposure assessment surveys were conducted at nine food production facilities and one flavor manufacturer where a total of 105 area and 74 personal samples were collected for 13 flavoring compounds including five ketones, five aldehydes, and three acids. The majority of the samples were below the limit of detection (LOD) for most compounds. Diacetyl had eight area and four personal samples above the LOD, whereas 2,3-pentanedione had three area samples above the LOD. The detectable values ranged from 25-3124 ppb and 15-172 ppb for diacetyl and 2,3-pentanedione respectively. These values exceed the proposed National Institute for Occupational Safety and Health (NIOSH) recommended exposure limit for these compounds. The aldehydes had the most detectable samples, with each of them having >50% of the samples above the LOD. Acetaldehyde had all but two samples above the LOD, however, these samples were below the OSHA PEL. It appears that in the food-manufacturing facilities surveyed here, exposure to the ketones occurs infrequently, however levels above the proposed NIOSH REL were found. Conversely, aldehyde exposure appears to be ubiquitous.
Performance limitations of label-free sensors in molecular diagnosis using complex samples
NASA Astrophysics Data System (ADS)
Varma, Manoj
2016-03-01
Label-free biosensors promised a paradigm involving direct detection of biomarkers from complex samples such as serum without requiring multistep sample processing typical of labelled methods such as ELISA or immunofluorescence assays. Label-free sensors have witnessed decades of development with a veritable zoo of techniques available today exploiting a multitude of physical effects. It is appropriate now to critically assess whether label-free technologies have succeeded in delivering their promise with respect to diagnostic applications, particularly, ambitious goals such as early cancer detection using serum biomarkers, which require low limits of detection (LoD). Comparison of nearly 120 limits of detection (LoD) values reported by labelled and label-free sensing approaches over a wide range of detection techniques and target molecules in serum revealed that labeled techniques achieve 2-3 orders of magnitude better LoDs. Data from experiments where labelled and label-free assays were performed simultaneously using the same assay parameters also confirm that the LoD achieved by labelled techniques is 2 to 3 orders of magnitude better than that by label-free techniques. Furthermore, label-free techniques required significant signal amplification, for e.g. using nanoparticle conjugated secondary antibodies, to achieve LoDs comparable to labelled methods substantially deviating from the original "direct detection" paradigm. This finding has important implications on the practical limits of applying label-free detection methods for molecular diagnosis.
METHODS OF DEALING WITH VALUES BELOW THE LIMIT OF DETECTION USING SAS
Due to limitations of chemical analysis procedures, small concentrations cannot be precisely measured. These concentrations are said to be below the limit of detection (LOD). In statistical analyses, these values are often censored and substituted with a constant value, such ...
Burgués, Javier; Marco, Santiago
2018-08-17
Metal oxide semiconductor (MOX) sensors are usually temperature-modulated and calibrated with multivariate models such as partial least squares (PLS) to increase the inherent low selectivity of this technology. The multivariate sensor response patterns exhibit heteroscedastic and correlated noise, which suggests that maximum likelihood methods should outperform PLS. One contribution of this paper is the comparison between PLS and maximum likelihood principal components regression (MLPCR) in MOX sensors. PLS is often criticized by the lack of interpretability when the model complexity increases beyond the chemical rank of the problem. This happens in MOX sensors due to cross-sensitivities to interferences, such as temperature or humidity and non-linearity. Additionally, the estimation of fundamental figures of merit, such as the limit of detection (LOD), is still not standardized in multivariate models. Orthogonalization methods, such as orthogonal projection to latent structures (O-PLS), have been successfully applied in other fields to reduce the complexity of PLS models. In this work, we propose a LOD estimation method based on applying the well-accepted univariate LOD formulas to the scores of the first component of an orthogonal PLS model. The resulting LOD is compared to the multivariate LOD range derived from error-propagation. The methodology is applied to data extracted from temperature-modulated MOX sensors (FIS SB-500-12 and Figaro TGS 3870-A04), aiming at the detection of low concentrations of carbon monoxide in the presence of uncontrolled humidity (chemical noise). We found that PLS models were simpler and more accurate than MLPCR models. Average LOD values of 0.79 ppm (FIS) and 1.06 ppm (Figaro) were found using the approach described in this paper. These values were contained within the LOD ranges obtained with the error-propagation approach. The mean LOD increased to 1.13 ppm (FIS) and 1.59 ppm (Figaro) when considering validation samples collected two weeks after calibration, which represents a 43% and 46% degradation, respectively. The orthogonal score-plot was a very convenient tool to visualize MOX sensor data and to validate the LOD estimates. Copyright © 2018 Elsevier B.V. All rights reserved.
Flavoring exposure in food manufacturing
Curwin, Brian D.; Deddens, Jim A.; McKernan, Lauralynn T.
2015-01-01
Flavorings are substances that alter or enhance the taste of food. Workers in the food-manufacturing industry, where flavorings are added to many products, may be exposed to any number of flavoring compounds. Although thousands of flavoring substances are in use, little is known about most of these in terms of worker health effects, and few have occupational exposure guidelines. Exposure assessment surveys were conducted at nine food production facilities and one flavor manufacturer where a total of 105 area and 74 personal samples were collected for 13 flavoring compounds including five ketones, five aldehydes, and three acids. The majority of the samples were below the limit of detection (LOD) for most compounds. Diacetyl had eight area and four personal samples above the LOD, whereas 2,3-pentanedione had three area samples above the LOD. The detectable values ranged from 25–3124 ppb and 15–172 ppb for diacetyl and 2,3-pentanedione respectively. These values exceed the proposed National Institute for Occupational Safety and Health (NIOSH) recommended exposure limit for these compounds. The aldehydes had the most detectable samples, with each of them having >50% of the samples above the LOD. Acetaldehyde had all but two samples above the LOD, however, these samples were below the OSHA PEL. It appears that in the food-manufacturing facilities surveyed here, exposure to the ketones occurs infrequently, however levels above the proposed NIOSH REL were found. Conversely, aldehyde exposure appears to be ubiquitous. PMID:25052692
Demenais, F; Lathrop, G M; Lalouel, J M
1988-07-01
A simulation study is here conducted to measure the power of the lod score method to detect linkage between a quantitative trait and a marker locus in various situations. The number of families necessary to detect such linkage with 80% power is assessed for different sets of parameters at the trait locus and different values of the recombination fraction. The effects of varying the mode of sampling families and the sibship size are also evaluated.
Are LOD and LOQ Reliable Parameters for Sensitivity Evaluation of Spectroscopic Methods?
Ershadi, Saba; Shayanfar, Ali
2018-03-22
The limit of detection (LOD) and the limit of quantification (LOQ) are common parameters to assess the sensitivity of analytical methods. In this study, the LOD and LOQ of previously reported terbium sensitized analysis methods were calculated by different methods, and the results were compared with sensitivity parameters [lower limit of quantification (LLOQ)] of U.S. Food and Drug Administration guidelines. The details of the calibration curve and standard deviation of blank samples of three different terbium-sensitized luminescence methods for the quantification of mycophenolic acid, enrofloxacin, and silibinin were used for the calculation of LOD and LOQ. A comparison of LOD and LOQ values calculated by various methods and LLOQ shows a considerable difference. The significant difference of the calculated LOD and LOQ with various methods and LLOQ should be considered in the sensitivity evaluation of spectroscopic methods.
A controlled comparison of the BacT/ALERT® 3D and VIRTUO™ microbial detection systems.
Totty, H; Ullery, M; Spontak, J; Viray, J; Adamik, M; Katzin, B; Dunne, W M; Deol, P
2017-10-01
The performance of the next-generation BacT/ALERT® VIRTUO™ Microbial Detection System (VIRTUO™, bioMérieux Inc., Hazelwood, MO) was compared to the BacT/ALERT® 3D Microbial Detection System (3D, bioMérieux Inc., Durham, NC) using BacT/ALERT® FA Plus (FA Plus), BacT/ALERT® PF Plus (PF Plus), BacT/ALERT® FN Plus (FN Plus), BacT/ALERT® Standard Aerobic (SA), and BacT/ALERT® Standard Anaerobic (SN) blood culture bottles (bioMérieux Inc., Durham, NC). A seeded limit of detection (LoD) study was performed for each bottle type in both systems. The LoD studies demonstrated that both systems were capable of detecting organisms at nearly identical levels [<10 colony-forming units (CFU) per bottle], with no significant difference. Following LoD determination, a seeded study was performed to compare the time to detection (TTD) between the systems using a panel of clinically relevant microorganisms inoculated at or near the LoD with 0, 4, or 10 mL of healthy human blood. VIRTUO™ exhibited a faster TTD by an average of 3.5 h, as well as demonstrated a significantly improved detection rate of 99.9% compared to 98.8% with 3D (p-value <0.05).
Posterior probability of linkage and maximal lod score.
Génin, E; Martinez, M; Clerget-Darpoux, F
1995-01-01
To detect linkage between a trait and a marker, Morton (1955) proposed to calculate the lod score z(theta 1) at a given value theta 1 of the recombination fraction. If z(theta 1) reaches +3 then linkage is concluded. However, in practice, lod scores are calculated for different values of the recombination fraction between 0 and 0.5 and the test is based on the maximum value of the lod score Zmax. The impact of this deviation of the test on the probability that in fact linkage does not exist, when linkage was concluded, is documented here. This posterior probability of no linkage can be derived by using Bayes' theorem. It is less than 5% when the lod score at a predetermined theta 1 is used for the test. But, for a Zmax of +3, we showed that it can reach 16.4%. Thus, considering a composite alternative hypothesis instead of a single one decreases the reliability of the test. The reliability decreases rapidly when Zmax is less than +3. Given a Zmax of +2.5, there is a 33% chance that linkage does not exist. Moreover, the posterior probability depends not only on the value of Zmax but also jointly on the family structures and on the genetic model. For a given Zmax, the chance that linkage exists may then vary.
NASA Astrophysics Data System (ADS)
Barefield, James E.; Judge, Elizabeth J.; Campbell, Keri R.; Colgan, James P.; Kilcrease, David P.; Johns, Heather M.; Wiens, Roger C.; McInroy, Rhonda E.; Martinez, Ronald K.; Clegg, Samuel M.
2016-06-01
Laser induced breakdown spectroscopy (LIBS) is a rapid atomic emission spectroscopy technique that can be configured for a variety of applications including space, forensics, and industry. LIBS can also be configured for stand-off distances or in-situ, under vacuum, high pressure, atmospheric or different gas environments, and with different resolving-power spectrometers. The detection of uranium in a complex geological matrix under different measurement schemes is explored in this paper. Although many investigations have been completed in an attempt to detect and quantify uranium in different matrices at in-situ and standoff distances, this work detects and quantifies uranium in a complex matrix under Martian and ambient air conditions. Investigation of uranium detection using a low resolving-power LIBS system at stand-off distances (1.6 m) is also reported. The results are compared to an in-situ LIBS system with medium resolving power and under ambient air conditions. Uranium has many thousands of emission lines in the 200-800 nm spectral region. In the presence of other matrix elements and at lower concentrations, the limit of detection of uranium is significantly reduced. The two measurement methods (low and high resolving-power spectrometers) are compared for limit of detection (LOD). Of the twenty-one potential diagnostic uranium emission lines, seven (409, 424, 434, 435, 436, 591, and 682 nm) have been used to determine the LOD for pitchblende in a dunite matrix using the ChemCam test bed LIBS system. The LOD values determined for uranium transitions in air are 409.013 nm (24,700 ppm), 424.167 nm (23,780 ppm), 434.169 nm (24,390 ppm), 435.574 nm (35,880 ppm), 436.205 nm (19,340 ppm), 591.539 nm (47,310 ppm), and 682.692 nm (18,580 ppm). The corresponding LOD values determined for uranium transitions in 7 Torr CO2 are 424.167 nm (25,760 ppm), 434.169 nm (40,800 ppm), 436.205 nm (32,050 ppm), 591.539 nm (15,340 ppm), and 682.692 nm (29,080 ppm). The LOD values determine for uranium emission lines using the medium resolving power (10,000 λ/Δλ) LIBS system for the dunite matrix in air are 409.013 nm (6120 ppm), 424.167 nm (5356 ppm), 434.169 nm (5693 ppm), 435.574 nm (6329 ppm), 436.205 nm (2142 ppm), and 682.692 nm (10,741 ppm). The corresponding LOD values determined for uranium transitions in a SiO2 matrix are 409.013 nm (272 ppm), 424.167 nm (268 ppm), 434.169 nm (402 ppm), 435.574 nm (1067 ppm), 436.205 nm (482 ppm), and 682.692 nm (720 ppm). The impact of spectral resolution, atmospheric conditions, matrix elements, and measurement distances on LOD is discussed. The measurements will assist one in selecting the proper system components based upon the application and the required analytical performance.
Limits of linearity and detection for some drugs of abuse.
Needleman, S B; Romberg, R W
1990-01-01
The limits of linearity (LOL) and detection (LOD) are important factors in establishing the reliability of an analytical procedure for accurately assaying drug concentrations in urine specimens. Multiple analyses of analyte over an extended range of concentrations provide a measure of the ability of the analytical procedure to correctly identify known quantities of drug in a biofluid matrix. Each of the seven drugs of abuse gives linear analytical responses from concentrations at or near their LOD to concentrations several-fold higher than those generally encountered in the drug screening laboratory. The upper LOL exceeds the Department of Navy (DON) cutoff values by factors of approximately 2 to 160. The LOD varies from 0.4 to 5.0% of the DON cutoff value for each drug. The limit of quantitation (LOQ) is calculated as the LOD + 7 SD. The range for LOL is greater for drugs analyzed with deuterated internal standards compared with those using conventional internal standards. For THC acid, cocaine, PCP, and morphine, LOLs are 8 to 160-fold greater than the defined cutoff concentrations. For the other drugs, the LOL's are only 2 to 4-fold greater than the defined cutoff concentrations.
The power and robustness of maximum LOD score statistics.
Yoo, Y J; Mendell, N R
2008-07-01
The maximum LOD score statistic is extremely powerful for gene mapping when calculated using the correct genetic parameter value. When the mode of genetic transmission is unknown, the maximum of the LOD scores obtained using several genetic parameter values is reported. This latter statistic requires higher critical value than the maximum LOD score statistic calculated from a single genetic parameter value. In this paper, we compare the power of maximum LOD scores based on three fixed sets of genetic parameter values with the power of the LOD score obtained after maximizing over the entire range of genetic parameter values. We simulate family data under nine generating models. For generating models with non-zero phenocopy rates, LOD scores maximized over the entire range of genetic parameters yielded greater power than maximum LOD scores for fixed sets of parameter values with zero phenocopy rates. No maximum LOD score was consistently more powerful than the others for generating models with a zero phenocopy rate. The power loss of the LOD score maximized over the entire range of genetic parameters, relative to the maximum LOD score calculated using the correct genetic parameter value, appeared to be robust to the generating models.
Strategy for determination of LOD and LOQ values--some basic aspects.
Uhrovčík, Jozef
2014-02-01
The paper is devoted to the evaluation of limit of detection (LOD) and limit of quantification (LOQ) values in concentration domain by using 4 different approaches; namely 3σ and 10σ approaches, ULA2 approach, PBA approach and MDL approach. Brief theoretical analyses of all above mentioned approaches are given together with directions for their practical use. Calculations and correct calibration design are exemplified by using of electrothermal atomic absorption spectrometry for determination of lead in drinking water sample. These validation parameters reached 1.6 μg L(-1) (LOD) and 5.4 μg L(-1) (LOQ) by using 3σ and 10σ approaches. For obtaining relevant values of analyte concentration the influence of calibration design and measurement methodology were examined. The most preferred technique has proven to be a method of preconcentration of the analyte on the surface of the graphite cuvette (boost cycle). © 2013 Elsevier B.V. All rights reserved.
Hühn, M
1995-05-01
Some approaches to molecular marker-assisted linkage detection for a dominant disease-resistance trait based on a segregating F2 population are discussed. Analysis of two-point linkage is carried out by the traditional measure of maximum lod score. It depends on (1) the maximum-likelihood estimate of the recombination fraction between the marker and the disease-resistance gene locus, (2) the observed absolute frequencies, and (3) the unknown number of tested individuals. If one replaces the absolute frequencies by expressions depending on the unknown sample size and the maximum-likelihood estimate of recombination value, the conventional rule for significant linkage (maximum lod score exceeds a given linkage threshold) can be resolved for the sample size. For each sub-population used for linkage analysis [susceptible (= recessive) individuals, resistant (= dominant) individuals, complete F2] this approach gives a lower bound for the necessary number of individuals required for the detection of significant two-point linkage by the lod-score method.
A practical approach to determination of laboratory GC-MS limits of detection.
Underwood, P J; Kananen, G E; Armitage, E K
1997-01-01
Determination of limit of detection (LOD) values in a forensic laboratory serves a fundamental forensic requirement for assay performance. In addition to demonstrating assay capability, LOD values can also be used to fulfill certification requirements of a high-volume forensic drug laboratory. The LOD was defined as the lowest concentration of drug that the laboratory can detect in a specimen with forensic certainty at a minimum of 85% of the time. Overall batch acceptance criteria included acceptable quantitation of control materials (within 20% of target), acceptable chromatography (symmetry, peak integration, peak shape, peak, and baseline resolution), retention time within +/-1% of the extracted standard, and mass ion ratios within +/-20% of the extracted standard mass ion ratios. Individual specimen acceptance criteria were the same as the batch acceptance criteria excluding the quantitation requirement. Data were collected from all instruments on different runs. A minimum of ten data points was required for each certified instrument, and a minimum of 85% of data points was acceptable. Quantitation within +/-20% of the LOD concentration was not required, but acceptable mass ratios were required. Data points with poor chromatography (internal standard failed mass ratios; interference of the baseline, for example, shoulders; asymmetry; and baseline resolution) was omitted from the acceptable rate calculation. Data points with good chromatography with failed mass ion ratios were included in the acceptable rate calculation. With these criteria, we established the following LODs: 11-nor-delta 9-tetrahydrocannabinol-9-carboxylic acid, 2 ng/mL; benzoylecgonine, 5 ng/mL; phencyclidine, 2.5 ng/mL; amphetamine, 150 ng/mL; methamphetamine, 100 ng/mL; codeine, 500 ng/mL; and morphine, 1000 ng/mL.
Krupčík, Ján; Májek, Pavel; Gorovenko, Roman; Blaško, Jaroslav; Kubinec, Robert; Sandra, Pat
2015-05-29
Methods based on the blank signal as proposed by IUPAC procedure and on the signal to noise ratio (S/N) as listed in the ISO-11843-1 norm for determination of the limit of detection (LOD) and quantitation (LOQ) in one-dimensional capillary gas chromatography (1D-GC) and comprehensive two-dimensional capillary gas chromatography (CG×GC) are described in detail and compared for both techniques. Flame ionization detection was applied and variables were the data acquisition frequency and, for CG×GC, also the modulation time. It has been stated that LOD and LOQ estimated according to IUPAC might be successfully used for 1D-GC-FID method. Moreover, LOD and LOQ decrease with decrease of data acquisition frequency (DAF). For GC×GC-FID, estimation of LOD by IUPAC gave poor reproducibility of results while for LOQ reproducibility was acceptable (within ±10% rel.). The LOD and LOQ determined by the S/N concept both for 1D-GC-FID and GC×GC-FID methods are ca. three times higher than those values estimated by the standard deviation of the blank. Since the distribution pattern of modulated peaks for any analyte separated by GC×GC is random and cannot be predicted, LOQ and LOD may vary within 30% for 3s modulation time. Concerning sensitivity, 1D-GC-FID at 2Hz and of GC×GC-FID at 50Hz shows a ca. 5 times enhancement of sensitivity in the modulated signal output. Copyright © 2015 Elsevier B.V. All rights reserved.
Combining markers with and without the limit of detection
Dong, Ting; Liu, Catherine Chunling; Petricoin, Emanuel F.; Tang, Liansheng Larry
2014-01-01
In this paper, we consider the combination of markers with and without the limit of detection (LOD). LOD is often encountered when measuring proteomic markers. Because of the limited detecting ability of an equipment or instrument, it is difficult to measure markers at a relatively low level. Suppose that after some monotonic transformation, the marker values approximately follow multivariate normal distributions. We propose to estimate distribution parameters while taking the LOD into account, and then combine markers using the results from the linear discriminant analysis. Our simulation results show that the ROC curve parameter estimates generated from the proposed method are much closer to the truth than simply using the linear discriminant analysis to combine markers without considering the LOD. In addition, we propose a procedure to select and combine a subset of markers when many candidate markers are available. The procedure based on the correlation among markers is different from a common understanding that a subset of the most accurate markers should be selected for the combination. The simulation studies show that the accuracy of a combined marker can be largely impacted by the correlation of marker measurements. Our methods are applied to a protein pathway dataset to combine proteomic biomarkers to distinguish cancer patients from non-cancer patients. PMID:24132938
Usta, Murat; Aral, Hale; Mete Çilingirtürk, Ahmet; Kural, Alev; Topaç, Ibrahim; Semerci, Tuna; Hicri Köseoğlu, Mehmet
2016-11-01
Average of normals (AON) is a quality control procedure that is sensitive only to systematic errors that can occur in an analytical process in which patient test results are used. The aim of this study was to develop an alternative model in order to apply the AON quality control procedure to datasets that include qualitative values below limit of detection (LoD). The reported patient test results for tumor markers, such as CA 15-3, CA 125, and CA 19-9, analyzed by two instruments, were retrieved from the information system over a period of 5 months, using the calibrator and control materials with the same lot numbers. The median as a measure of central tendency and the median absolute deviation (MAD) as a measure of dispersion were used for the complementary model of AON quality control procedure. The u bias values, which were determined for the bias component of the measurement uncertainty, were partially linked to the percentages of the daily median values of the test results that fall within the control limits. The results for these tumor markers, in which lower limits of reference intervals are not medically important for clinical diagnosis and management, showed that the AON quality control procedure, using the MAD around the median, can be applied for datasets including qualitative values below LoD.
Ruecker, Norma J.; Hoffman, Rebecca M.; Chalmers, Rachel M.; Neumann, Norman F.
2011-01-01
Molecular methods incorporating nested PCR-restriction fragment length polymorphism (RFLP) analysis of the 18S rRNA gene of Cryptosporidium species were validated to assess performance based on limit of detection (LoD) and for detecting and resolving mixtures of species and genotypes within a single sample. The 95% LoD was determined for seven species (Cryptosporidium hominis, C. parvum, C. felis, C. meleagridis, C. ubiquitum, C. muris, and C. andersoni) and ranged from 7 to 11 plasmid template copies with overlapping 95% confidence limits. The LoD values for genomic DNA from oocysts on microscope slides were 7 and 10 template copies for C. andersoni and C. parvum, respectively. The repetitive nested PCR-RFLP slide protocol had an LoD of 4 oocysts per slide. When templates of two species were mixed in equal ratios in the nested PCR-RFLP reaction mixture, there was no amplification bias toward one species over another. At high ratios of template mixtures (>1:10), there was a reduction or loss of detection of the less abundant species by RFLP analysis, most likely due to heteroduplex formation in the later cycles of the PCR. Replicate nested PCR was successful at resolving many mixtures of Cryptosporidium at template concentrations near or below the LoD. The cloning of nested PCR products resulted in 17% of the cloned sequences being recombinants of the two original templates. Limiting-dilution nested PCR followed by the sequencing of PCR products resulted in no sequence anomalies, suggesting that this method is an effective and accurate way to study the species diversity of Cryptosporidium, particularly for environmental water samples, in which mixtures of parasites are common. PMID:21498746
Salter, Robert; Holmes, Steven; Legg, David; Coble, Joel; George, Bruce
2012-02-01
Pork tissue samples that tested positive and negative by the Charm II tetracycline test screening method in the slaughter plant laboratory were tested with the modified AOAC International liquid chromatography tandem mass spectrometry (LC-MS-MS) method 995.09 to determine the predictive value of the screening method at detecting total tetracyclines at 10 μg/kg of tissue, in compliance with Russian import regulations. There were 218 presumptive-positive tetracycline samples of 4,195 randomly tested hogs. Of these screening test positive samples, 83% (182) were positive, >10 μg/kg by LC-MS-MS; 12.8% (28) were false violative, greater than limit of detection (LOD) but <10 μg/kg; and 4.2% (8) were not detected at the LC-MS-MS LOD. The 36 false-violative and not-detected samples represent 1% of the total samples screened. Twenty-seven of 30 randomly selected tetracycline screening negative samples tested below the LC-MS-MS LOD, and 3 samples tested <3 μg/kg chlortetracycline. Results indicate that the Charm II tetracycline test is effective at predicting hogs containing >10 μg/kg total tetracyclines in compliance with Russian import regulations.
Estimation of the limit of detection using information theory measures.
Fonollosa, Jordi; Vergara, Alexander; Huerta, Ramón; Marco, Santiago
2014-01-31
Definitions of the limit of detection (LOD) based on the probability of false positive and/or false negative errors have been proposed over the past years. Although such definitions are straightforward and valid for any kind of analytical system, proposed methodologies to estimate the LOD are usually simplified to signals with Gaussian noise. Additionally, there is a general misconception that two systems with the same LOD provide the same amount of information on the source regardless of the prior probability of presenting a blank/analyte sample. Based upon an analogy between an analytical system and a binary communication channel, in this paper we show that the amount of information that can be extracted from an analytical system depends on the probability of presenting the two different possible states. We propose a new definition of LOD utilizing information theory tools that deals with noise of any kind and allows the introduction of prior knowledge easily. Unlike most traditional LOD estimation approaches, the proposed definition is based on the amount of information that the chemical instrumentation system provides on the chemical information source. Our findings indicate that the benchmark of analytical systems based on the ability to provide information about the presence/absence of the analyte (our proposed approach) is a more general and proper framework, while converging to the usual values when dealing with Gaussian noise. Copyright © 2013 Elsevier B.V. All rights reserved.
Hutchison, J R; Piepel, G F; Amidan, B G; Hess, B M; Sydor, M A; Deatherage Kaiser, B L
2018-05-01
We evaluated the effects of Bacillus anthracis surrogates, low surface concentrations, surface materials and assay methods on false-negative rate (FNR) and limit of detection (LOD 95 ) for recovering Bacillus spores using a macrofoam-swab sampling procedure. Bacillus anthracis Sterne or Bacillus atrophaeus Nakamura spores were deposited over a range of low target concentrations (2-500 per coupon) onto glass, stainless steel, vinyl tile and plastic. Samples were assayed using a modified Rapid Viability-PCR (mRV-PCR) method and the traditional plate culture method to obtain FNR and LOD 95 results. Mean FNRs tended to be lower for mRV-PCR compared to culturing, and increased as spore concentration decreased for all surface materials. Surface material, but not B. anthracis surrogate, influenced FNRs with the mRV-PCR method. The mRV-PCR LOD 95 was lowest for glass and highest for vinyl tile. LOD 95 values overall were lower for mRV-PCR than for the culture method. This study adds to the limited data on FNR and LOD 95 for mRV-PCR and culturing methods with low concentrations of B. anthracis sampled from various surface materials by the CDC macrofoam-swab method. These are key inputs for planning characterization and clearance studies for low contamination levels of B. anthracis. © 2018 The Society for Applied Microbiology.
Zhang, Yingjie; Liu, Qiqi; Zhou, Biao; Wang, Xiaobo; Chen, Suhong; Wang, Shengqi
2017-01-25
Mosquito-borne viruses (MBVs) and parasites (MBPs) are transmitted through hematophagous arthropods-mosquitoes to homoiothermous vertebrates. This study aims at developing a detection method to monitor the spread of mosquito-borne diseases to new areas and diagnose the infections caused by MBVs and MBPs. In this assay, an ultra-sensitive chemiluminescence (CL) detection method was developed and used to simultaneously detect 19 common MBVs and MBPs. In vitro transcript RNA, virus-like particles (VLPs), and plasmids were established as positive or limit of detection (LOD) reference materials. MBVs and MBPs could be genotyped with high sensitivity and specificity. The cut-off values of probes were calculated. The absolute LODs of this strategy to detect serially diluted in vitro transcribed RNAs of MBVs and serially diluted plasmids of MBPs were 10 2 -10 3 copies/μl and 10 1 -10 2 copies/μl, respectively. Further, the LOD of detecting a strain of pre-quantified JEV was 10 1.8 -10 0.8 PFU/ml, fitted well in a linear regression model (coefficient of determination = 0.9678). Ultra-sensitive CL imaging DNA hybridization was developed and could simultaneously detect various MBVs and MBPs. The method described here has the potential to provide considerable labor savings due to its ability to screen for 19 mosquito-borne pathogens simultaneously.
Campillo-Brocal, Jonatan C; Chacón-Verdú, María Dolores; Lucas-Elío, Patricia; Sánchez-Amat, Antonio
2015-03-24
L-Amino acid oxidases (LAOs) have been generally described as flavoproteins that oxidize amino acids releasing the corresponding ketoacid, ammonium and hydrogen peroxide. The generation of hydrogen peroxide gives to these enzymes antimicrobial characteristics. They are involved in processes such as biofilm development and microbial competition. LAOs are of great biotechnological interest in different applications such as the design of biosensors, biotransformations and biomedicine. The marine bacterium Marinomonas mediterranea synthesizes LodA, the first known LAO that contains a quinone cofactor. LodA is encoded in an operon that contains a second gene coding for LodB, a protein required for the post-translational modification generating the cofactor. Recently, GoxA, a quinoprotein with sequence similarity to LodA but with a different enzymatic activity (glycine oxidase instead of lysine-ε-oxidase) has been described. The aim of this work has been to study the distribution of genes similar to lodA and/or goxA in sequenced microbial genomes and to get insight into the evolution of this novel family of proteins through phylogenetic analysis. Genes encoding LodA-like proteins have been detected in several bacterial classes. However, they are absent in Archaea and detected only in a small group of fungi of the class Agaromycetes. The vast majority of the genes detected are in a genome region with a nearby lodB-like gene suggesting a specific interaction between both partner proteins. Sequence alignment of the LodA-like proteins allowed the detection of several conserved residues. All of them showed a Cys and a Trp that aligned with the residues that are forming part of the cysteine tryptophilquinone (CTQ) cofactor in LodA. Phylogenetic analysis revealed that LodA-like proteins can be clustered in different groups. Interestingly, LodA and GoxA are in different groups, indicating that those groups are related to the enzymatic activity of the proteins detected. Genome mining has revealed for the first time the broad distribution of LodA-like proteins containing a CTQ cofactor in many different microbial groups. This study provides a platform to explore the potentially novel enzymatic activities of the proteins detected, the mechanisms of post-translational modifications involved in their synthesis, as well as their biological relevance.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hutchison, Janine R.; Piepel, Gregory F.; Amidan, Brett G.
Surface sampling for Bacillus anthracis spores has traditionally relied on detection via bacterial cultivation methods. Although effective, this approach does not provide the level of organism specificity that can be gained through molecular techniques. False negative rates (FNR) and limits of detection (LOD) were determined for two B. anthracis surrogates with modified rapid viability-polymerase chain reaction (mRV-PCR) following macrofoam-swab sampling. This study was conducted in parallel with a previously reported study that analyzed spores using a plate-culture method. B. anthracis Sterne (BAS) or B. atrophaeus Nakamura (BG) spores were deposited onto four surface materials (glass, stainless steel, vinyl tile, andmore » plastic) at nine target concentrations (2 to 500 spores/coupon; 0.078 to 19.375 colony-forming units [CFU] per cm2). Mean FNR values for mRV-PCR analysis ranged from 0 to 0.917 for BAS and 0 to 0.875 for BG and increased as spore concentration decreased (over the concentrations investigated) for each surface material. FNRs based on mRV-PCR data were not statistically different for BAS and BG, but were significantly lower for glass than for vinyl tile. FNRs also tended to be lower for the mRV-PCR method compared to the culture method. The mRV-PCR LOD95 was lowest for glass (0.429 CFU/cm2 with BAS and 0.341 CFU/cm2 with BG) and highest for vinyl tile (0.919 CFU/cm2 with BAS and 0.917 CFU/cm2 with BG). These mRV-PCR LOD95 values were lower than the culture values (BAS: 0.678 to 1.023 CFU/cm2 and BG: 0.820 to 1.489 CFU/cm2). The FNR and LOD95 values reported in this work provide guidance for environmental sampling of Bacillus spores at low concentrations.« less
Yueh, Fang-Yu; Sharma, Ramesh C; Singh, Jagdish P; Zhang, Hansheng; Spencer, William A
2002-11-01
The analytical figure of merit of the potential of laser-induced breakdown spectroscopy (LIBS) has been evaluated for detection of trace element in liquid. LIBS data of Mg, Cr, Mn, and Re were studied. Various optical geometries, which produce the laser spark in and at the liquid sample, were tested. The calibration curves for Mg, Cr, Mn, and Re were obtained at the optimized experimental conditions with bulk liquid and in liquid jet. It was found that measurements using a liquid jet provide better detection limits than bulk liquid measurements. The limits of detection (LOD) of Mg, Cr, Mn, and Re in the present liquid jet measurement are found to be 0.1, 0.4, 0.7, and 8 ppm, respectively. The LOD of Mg using Mg 279.55 nm was compared with the values found in other liquid work.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hutchison, J. R.; Piepel, G. F.; Amidan, B. G.
Aims: We evaluated the effects of Bacillus anthracis surrogates, low surface concentrations, surface materials, and assay methods on false-negative rate (FNR) and limit of detection (LOD95) for recovering Bacillus spores using a macrofoam-swab sampling procedure. Methods and Results: Bacillus anthracis Sterne or Bacillus atrophaeus Nakamura spores were deposited over a range of low target concentrations (2 – 500 coupon-1) onto glass, stainless steel, vinyl tile, and plastic. Samples were assayed using a modified Rapid Viability-PCR (mRV-PCR) method and the traditional plate culture method to obtain FNR and LOD95 results. Conclusions: Mean FNRs tended to be lower for mRV-PCR compared tomore » culturing, and increased as spore concentration decreased for all surface materials. Surface material, but not B. anthracis surrogate, influenced FNRs with the mRV-PCR method. The mRV-PCR LOD95 was lowest for glass and highest for vinyl tile. LOD95 values overall were lower for mRV-PCR than for the culture method. Significance and Impact of Study: This study adds to the limited data on FNR and LOD95 for mRV-PCR and culturing methods with low concentrations of B. anthracis sampled from various surface materials by the CDC macrofoam-swab method. These are key inputs for planning characterization and clearance studies for low contamination levels of B. anthracis.« less
Percentiles of the null distribution of 2 maximum lod score tests.
Ulgen, Ayse; Yoo, Yun Joo; Gordon, Derek; Finch, Stephen J; Mendell, Nancy R
2004-01-01
We here consider the null distribution of the maximum lod score (LOD-M) obtained upon maximizing over transmission model parameters (penetrance values, dominance, and allele frequency) as well as the recombination fraction. Also considered is the lod score maximized over a fixed choice of genetic model parameters and recombination-fraction values set prior to the analysis (MMLS) as proposed by Hodge et al. The objective is to fit parametric distributions to MMLS and LOD-M. Our results are based on 3,600 simulations of samples of n = 100 nuclear families ascertained for having one affected member and at least one other sibling available for linkage analysis. Each null distribution is approximately a mixture p(2)(0) + (1 - p)(2)(v). The values of MMLS appear to fit the mixture 0.20(2)(0) + 0.80chi(2)(1.6). The mixture distribution 0.13(2)(0) + 0.87chi(2)(2.8). appears to describe the null distribution of LOD-M. From these results we derive a simple method for obtaining critical values of LOD-M and MMLS. Copyright 2004 S. Karger AG, Basel
Xu, Xiaoma; van de Craats, Anick M; de Bruyn, Peter C A M
2004-11-01
A highly sensitive screening method based on high performance liquid chromatography atmospheric pressure ionization mass spectrometry (HPLC-API-MS) has been developed for the analysis of 21 nitroaromatic, nitramine and nitrate ester explosives, which include the explosives most commonly encountered in forensic science. Two atmospheric pressure ionization (API) methods, atmospheric pressure chemical ionization (APCI) and electrospray ionization (ESI), and various experimental conditions have been applied to allow for the detection of all 21 explosive compounds. The limit of detection (LOD) in the full-scan mode has been found to be 0.012-1.2 ng on column for the screening of most explosives investigated. For nitrobenzene, an LOD of 10 ng was found with the APCI method in the negative mode. Although the detection of nitrobenzene, 2-, 3-, and 4-nitrotoluene is hindered by the difficult ionization of these compounds, we have found that by forming an adduct with glycine, LOD values in the range of 3-16 ng on column can be achieved. Compared with previous screening methods with thermospray ionization, the API method has distinct advantages, including simplicity and stability of the method applied, an extended screening range and a low detection limit for the explosives studied.
Dołowy, Małgorzata; Kulpińska-Kucia, Katarzyna; Pyka, Alina
2014-01-01
A new specific, precise, accurate, and robust TLC-densitometry has been developed for the simultaneous determination of hydrocortisone acetate and lidocaine hydrochloride in combined pharmaceutical formulation. The chromatographic analysis was carried out using a mobile phase consisting of chloroform + acetone + ammonia (25%) in volume composition 8 : 2 : 0.1 and silica gel 60F254 plates. Densitometric detection was performed in UV at wavelengths 200 nm and 250 nm, respectively, for lidocaine hydrochloride and hydrocortisone acetate. The validation of the proposed method was performed in terms of specificity, linearity, limit of detection (LOD), limit of quantification (LOQ), precision, accuracy, and robustness. The applied TLC procedure is linear in hydrocortisone acetate concentration range of 3.75 ÷ 12.50 μg·spot−1, and from 1.00 ÷ 2.50 μg·spot−1 for lidocaine hydrochloride. The developed method was found to be accurate (the value of the coefficient of variation CV [%] is less than 3%), precise (CV [%] is less than 2%), specific, and robust. LOQ of hydrocortisone acetate is 0.198 μg·spot−1 and LOD is 0.066 μg·spot−1. LOQ and LOD values for lidocaine hydrochloride are 0.270 and 0.090 μg·spot−1, respectively. The assay value of both bioactive substances is consistent with the limits recommended by Pharmacopoeia. PMID:24526880
Dołowy, Małgorzata; Kulpińska-Kucia, Katarzyna; Pyka, Alina
2014-01-01
A new specific, precise, accurate, and robust TLC-densitometry has been developed for the simultaneous determination of hydrocortisone acetate and lidocaine hydrochloride in combined pharmaceutical formulation. The chromatographic analysis was carried out using a mobile phase consisting of chloroform+acetone+ammonia (25%) in volume composition 8:2:0.1 and silica gel 60F254 plates. Densitometric detection was performed in UV at wavelengths 200 nm and 250 nm, respectively, for lidocaine hydrochloride and hydrocortisone acetate. The validation of the proposed method was performed in terms of specificity, linearity, limit of detection (LOD), limit of quantification (LOQ), precision, accuracy, and robustness. The applied TLC procedure is linear in hydrocortisone acetate concentration range of 3.75÷12.50 μg·spot(-1), and from 1.00÷2.50 μg·spot(-1) for lidocaine hydrochloride. The developed method was found to be accurate (the value of the coefficient of variation CV [%] is less than 3%), precise (CV [%] is less than 2%), specific, and robust. LOQ of hydrocortisone acetate is 0.198 μg·spot(-1) and LOD is 0.066 μg·spot(-1). LOQ and LOD values for lidocaine hydrochloride are 0.270 and 0.090 μg·spot(-1), respectively. The assay value of both bioactive substances is consistent with the limits recommended by Pharmacopoeia.
Lakshmi, I Karthika; Putty, Kalyani; Raut, Satya Samparna; Patil, Sunil R; Rao, P P; Bhagyalakshmi, B; Jyothi, Y Krishna; Susmitha, B; Reddy, Y Vishnuvardhan; Kasulanati, Sowmya; Jyothi, J Shiva; Reddy, Y N
2018-04-01
The present study was designed to standardize real-time polymerase chain reaction (PCR) for detecting the bluetongue virus from blood samples of sheep collected during outbreaks of bluetongue disease in the year 2014 in Andhra Pradesh and Telangana states of India. A 10-fold serial dilution of Plasmid PUC59 with bluetongue virus (BTV) NS3 insert was used to plot the standard curve. BHK-21 and KC cells were used for in vitro propagation of virus BTV-9 at a TCID50/ml of 10 5 ml and RNA was isolated by the Trizol method. Both reverse transcription-PCR and real-time PCR using TaqMan probe were carried out with RNA extracted from virus-spiked culture medium and blood to compare the sensitivity by means of finding out the limit of detection (LoD). The results were verified by inoculating the detected and undetected dilutions onto cell cultures with further cytological (cytopathic effect) and molecular confirmation (by BTV-NS1 group-specific PCR). The standardized technique was then applied to field samples (blood) for detecting BTV. The slope of the standard curve obtained was -3.23, and the efficiency was 103%. The LoD with RT-PCR was 8.269E×10 3 number of copies of plasmid, whereas it was 13 with real-time PCR for plasmid dilutions. Similarly, LoD was determined for virus-spiked culture medium, and blood with both the types of PCR and the values were 10 3 TCID 50/ml and 10 4 TCID 50/ml with RT-PCR and 10° TCID 50/ml and 10 2 TCID 50/ml with real-time PCR, respectively. The standardized technique was applied to blood samples collected from BTV suspected animals; 10 among 20 samples were found positive with Cq values ranging from 27 to 39. The Cq value exhibiting samples were further processed in cell cultures and were confirmed to be BT positive. Likewise, Cq undetected samples on processing in cell cultures turned out to be BTV negative. Real-time PCR was found to be a very sensitive as well as reliable method to detect BTV present in different types of samples, including blood samples collected from BTV-infected sheep, compared to RT-PCR. The LoD of BTV is likely influenced by sample type, possibly by the interference by the other components present in the sample.
Sezer, Banu; Velioglu, Hasan Murat; Bilge, Gonca; Berkkan, Aysel; Ozdinc, Nese; Tamer, Ugur; Boyaci, Ismail Hakkı
2018-01-01
The use of Li salts in foods has been prohibited due to their negative effects on central nervous system; however, they might still be used especially in meat products as Na substitutes. Lithium can be toxic and even lethal at higher concentrations and it is not approved in foods. The present study focuses on Li analysis in meatballs by using laser induced breakdown spectroscopy (LIBS). Meatball samples were analyzed using LIBS and flame atomic absorption spectroscopy. Calibration curves were obtained by utilizing Li emission lines at 610nm and 670nm for univariate calibration. The results showed that Li calibration curve at 670nm provided successful determination of Li with 0.965 of R 2 and 4.64ppm of limit of detection (LOD) value. While Li Calibration curve obtained using emission line at 610nm generated R 2 of 0.991 and LOD of 22.6ppm, calibration curve obtained at 670nm below 1300ppm generated R 2 of 0.965 and LOD of 4.64ppm. Copyright © 2017. Published by Elsevier Ltd.
USDA-ARS?s Scientific Manuscript database
The limit of detection (LOD) for qPCR-based analyses is not consistently defined or determined in studies on waterborne pathogens. Moreover, the LODs reported often reflect the qPCR assay rather than the entire sample process. Our objective was to develop a method to determine the 95% LOD (lowest co...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Campbell, Keri R.; Judge, Elizabeth J.; Barefield, James E.
We show the analysis of light water reactor simulated used nuclear fuel using laser-induced breakdown spectroscopy (LIBS) is explored using a simplified version of the main oxide phase. The main oxide phase consists of the actinides, lanthanides, and zirconium. The purpose of this study is to develop a rapid, quantitative technique for measuring zirconium in a uranium dioxide matrix without the need to dissolve the material. A second set of materials including cerium oxide is also analyzed to determine precision and limit of detection (LOD) using LIBS in a complex matrix. Two types of samples are used in this study:more » binary and ternary oxide pellets. The ternary oxide, (U,Zr,Ce)O 2 pellets used in this study are a simplified version the main oxide phase of used nuclear fuel. The binary oxides, (U,Ce)O 2 and (U,Zr)O 2 are also examined to determine spectral emission lines for Ce and Zr, potential spectral interferences with uranium and baseline LOD values for Ce and Zr in a UO 2 matrix. In the spectral range of 200 to 800 nm, 33 cerium lines and 25 zirconium lines were identified and shown to have linear correlation values (R 2) > 0.97 for both the binary and ternary oxides. The cerium LOD in the (U,Ce)O 2 matrix ranged from 0.34 to 1.08 wt% and 0.94 to 1.22 wt% in (U,Ce,Zr)O 2 for 33 of Ce emission lines. The zirconium limit of detection in the (U,Zr)O 2 matrix ranged from 0.84 to 1.15 wt% and 0.99 to 1.10 wt% in (U,Ce,Zr)O 2 for 25 Zr lines. Finally, the effect of multiple elements in the plasma and the impact on the LOD is discussed.« less
The power to detect linkage in complex disease by means of simple LOD-score analyses.
Greenberg, D A; Abreu, P; Hodge, S E
1998-01-01
Maximum-likelihood analysis (via LOD score) provides the most powerful method for finding linkage when the mode of inheritance (MOI) is known. However, because one must assume an MOI, the application of LOD-score analysis to complex disease has been questioned. Although it is known that one can legitimately maximize the maximum LOD score with respect to genetic parameters, this approach raises three concerns: (1) multiple testing, (2) effect on power to detect linkage, and (3) adequacy of the approximate MOI for the true MOI. We evaluated the power of LOD scores to detect linkage when the true MOI was complex but a LOD score analysis assumed simple models. We simulated data from 14 different genetic models, including dominant and recessive at high (80%) and low (20%) penetrances, intermediate models, and several additive two-locus models. We calculated LOD scores by assuming two simple models, dominant and recessive, each with 50% penetrance, then took the higher of the two LOD scores as the raw test statistic and corrected for multiple tests. We call this test statistic "MMLS-C." We found that the ELODs for MMLS-C are >=80% of the ELOD under the true model when the ELOD for the true model is >=3. Similarly, the power to reach a given LOD score was usually >=80% that of the true model, when the power under the true model was >=60%. These results underscore that a critical factor in LOD-score analysis is the MOI at the linked locus, not that of the disease or trait per se. Thus, a limited set of simple genetic models in LOD-score analysis can work well in testing for linkage. PMID:9718328
The power to detect linkage in complex disease by means of simple LOD-score analyses.
Greenberg, D A; Abreu, P; Hodge, S E
1998-09-01
Maximum-likelihood analysis (via LOD score) provides the most powerful method for finding linkage when the mode of inheritance (MOI) is known. However, because one must assume an MOI, the application of LOD-score analysis to complex disease has been questioned. Although it is known that one can legitimately maximize the maximum LOD score with respect to genetic parameters, this approach raises three concerns: (1) multiple testing, (2) effect on power to detect linkage, and (3) adequacy of the approximate MOI for the true MOI. We evaluated the power of LOD scores to detect linkage when the true MOI was complex but a LOD score analysis assumed simple models. We simulated data from 14 different genetic models, including dominant and recessive at high (80%) and low (20%) penetrances, intermediate models, and several additive two-locus models. We calculated LOD scores by assuming two simple models, dominant and recessive, each with 50% penetrance, then took the higher of the two LOD scores as the raw test statistic and corrected for multiple tests. We call this test statistic "MMLS-C." We found that the ELODs for MMLS-C are >=80% of the ELOD under the true model when the ELOD for the true model is >=3. Similarly, the power to reach a given LOD score was usually >=80% that of the true model, when the power under the true model was >=60%. These results underscore that a critical factor in LOD-score analysis is the MOI at the linked locus, not that of the disease or trait per se. Thus, a limited set of simple genetic models in LOD-score analysis can work well in testing for linkage.
NASA Astrophysics Data System (ADS)
Mohamed, Walid Tawfik Y.
2008-02-01
Laser-induced breakdown spectroscopy (LIBS) is a laser-based technique that can provide non-intrusive, qualitative and quantitative measurement of metals in various environments. LIBS uses the plasma generated by a high-energy laser beam to prepare and excite the sample in one step. In the present work, LIBS has been applied to perform elemental analysis of six trace elements simultaneously in aluminum alloy targets. The plasma is generated by focusing a pulsed Nd:YAG laser on the target in air at atmospheric pressure. LIBS limit of detection (LOD) is affected by many experimental parameters such as interferences, self-absorption, spectral overlap and matrix effect. We aimed to improve the LIBS LOD by optimizing these experimental parameters as possible. In doing so, a portable Echelle spectrometer with intensified CCD camera was used to detect the LIBS plasma emission. This advanced Echelle spectrometer provides a constant spectral resolution (CSR) of 7500 corresponding to 4 pixels FWHM over a wavelength range 200-1000 nm displayable in a single spectrum. Then, the calibration curves for iron, beryllium, magnesium, silicon, manganese and copper as minor elements were achieved with linear regression coefficients between 98-99% on average in aluminum standard sample alloys. New LOD values were achieved in the ppm range with high precision (RSD 3-8%). From the application view point, improving LIBS LOD is very important in the on-line industrial process control to follow-up multi-elements for the correct alloying in metals.
NASA Astrophysics Data System (ADS)
Takakura, T.; Yanagi, I.; Goto, Y.; Ishige, Y.; Kohara, Y.
2016-03-01
We developed a resistive-pulse sensor with a solid-state pore and measured the latex agglutination of submicron particles induced by antigen-antibody interaction for single-molecule detection of proteins. We fabricated the pore based on numerical simulation to clearly distinguish between monomer and dimer latex particles. By measuring single dimers agglutinated in the single-molecule regime, we detected single human alpha-fetoprotein molecules. Adjusting the initial particle concentration improves the limit of detection (LOD) to 95 fmol/l. We established a theoretical model of the LOD by combining the reaction kinetics and the counting statistics to explain the effect of initial particle concentration on the LOD. The theoretical model shows how to improve the LOD quantitatively. The single-molecule detection studied here indicates the feasibility of implementing a highly sensitive immunoassay by a simple measurement method using resistive-pulse sensing.
NASA Astrophysics Data System (ADS)
Wu, Xiaomeng; Han, Caiqin; Chen, Jing; Huang, Yao-Wen; Zhao, Yiping
2016-04-01
The detection of Salmonella Poona from cantaloupe cubes and E. coli O157:H7 from lettuce has been explored by using a filtration method and surface-enhanced Raman spectroscopy (SERS) based on vancomycin-functionalized silver nanorod array substrates. It is found that with a two-step filtration process, the limit of detection (LOD) of Salmonella Poona from cantaloupe cubes can be as low as 100 CFU/mL in less than 4 h, whereas the chlorophyll in the lettuce causes severe SERS spectral interference. To improve the LOD of lettuce, a three-step filtration method with a hydrophobic filter is proposed. The hydrophobic filter can effectively eliminate the interferences from chlorophyll and achieve a LOD of 1000 CFU/mL detection of E. coli O157:H7 from lettuce samples within 5 h. With the low LODs and rapid detection time, the SERS biosensing platform has demonstrated its potential as a rapid, simple, and inexpensive means for pathogenic bacteria detection from fresh produce.
Abafe, Ovokeroye A; Späth, Jana; Fick, Jerker; Jansson, Stina; Buckley, Chris; Stark, Annegret; Pietruschka, Bjoern; Martincigh, Bice S
2018-06-01
South Africa has the largest occurrence of the human immune deficiency virus (HIV) in the world but has also implemented the largest antiretroviral (ARV) treatment programme. It was therefore of interest to determine the presence and concentrations of commonly used antiretroviral drugs (ARVDs) and, also, to determine the capabilities of wastewater treatment plants (WWTPs) for removing ARVDs. To this end, a surrogate standard based LC-MS/MS method was optimized and applied for the detection of thirteen ARVDs used in the treatment and management of HIV/acquired immune deficiency syndrome (HIV/AIDS) in two major and one modular WWTP in the eThekwini Municipality in KwaZulu-Natal, South Africa. The method was validated and the detection limits fell within the range of 2-20 ng L -1 . The analytical recoveries for the ARVDs were mainly greater than 50% with acceptable relative standard deviations. The concentration values ranged from
Ryvolová, Markéta; Preisler, Jan; Foret, Frantisek; Hauser, Peter C; Krásenský, Pavel; Paull, Brett; Macka, Mirek
2010-01-01
This work for the first time combines three on-capillary detection methods, namely, capacitively coupled contactless conductometric (C(4)D), photometric (PD), and fluorimetric (FD), in a single (identical) point of detection cell, allowing concurrent measurements at a single point of detection for use in capillary electrophoresis, capillary electrochromatography, and capillary/nanoliquid chromatography. The novel design is based on a standard 6.3 mm i.d. fiber-optic SMA adapter with a drilled opening for the separation capillary to go through, to which two concentrically positioned C(4)D detection electrodes with a detection gap of 7 mm were added on each side acting simultaneously as capillary guides. The optical fibers in the SMA adapter were used for the photometric signal (absorbance), and another optical fiber at a 45 degrees angle to the capillary was applied to collect the emitted light for FD. Light emitting diodes (255 and 470 nm) were used as light sources for the PD and FD detection modes. LOD values were determined under flow-injection conditions to exclude any stacking effects: For the 470 nm LED limits of detection (LODs) for FD and PD were for fluorescein (1 x 10(-8) mol/L) and tartrazine (6 x 10(-6) mol/L), respectively, and the LOD for the C(4)D was for magnesium chloride (5 x 10(-7) mol/L). The advantage of the three different detection signals in a single point is demonstrated in capillary electrophoresis using model mixtures and samples including a mixture of fluorescent and nonfluorescent dyes and common ions, underivatized amino acids, and a fluorescently labeled digest of bovine serum albumin.
Lalani, Tahaniyat; Tisdale, Michele D; Maguire, Jason D; Wongsrichanalai, Chansuda; Riddle, Mark S; Tribble, David R
2015-01-01
We evaluated the limits of detection (LoD) for an 11-plex PCR-Luminex assay performed on Whatman FTA Elute cards smeared with stool containing pathogens associated with travelers’ diarrhea. LoDs ranged between 102-105 CFU, PFU or cysts/g for most pathogens except Cryptosporidium. Campylobacter and norovirus LoD increased with prolonged storage of cards. PMID:26072151
Estimation of the POD function and the LOD of a qualitative microbiological measurement method.
Wilrich, Cordula; Wilrich, Peter-Theodor
2009-01-01
Qualitative microbiological measurement methods in which the measurement results are either 0 (microorganism not detected) or 1 (microorganism detected) are discussed. The performance of such a measurement method is described by its probability of detection as a function of the contamination (CFU/g or CFU/mL) of the test material, or by the LOD(p), i.e., the contamination that is detected (measurement result 1) with a specified probability p. A complementary log-log model was used to statistically estimate these performance characteristics. An intralaboratory experiment for the detection of Listeria monocytogenes in various food matrixes illustrates the method. The estimate of LOD50% is compared with the Spearman-Kaerber method.
Shen, Zonglin; Jiang, Linling; Yang, Shuran; Ye, Jing; Dai, Nan; Liu, Xiaoyan; Li, Na; Lu, Jin; Liu, Fang; Lu, Yi; Sun, Xuejin; Cheng, Yuqi; Xu, Xiufeng
2017-01-01
Previous work exhibited different brain grey matter volume (GMV) changes between patients with early adult onset depression (EOD, age 18-29) and later adult onset depression (LOD, age 30-44) by using 30-year-old as the cut-off age. To identify whether regional homogeneity (ReHo) changes are also different between EOD and LOD by using same cut-off age, we used resting-state functional magnetic resonance imaging (fMRI) to detect the abnormal ReHo between patients with EOD and LOD in the present study. Resting-state fMRI scans of 58 patients with EOD, 62 patients with LOD, 60 young healthy controls (HC), and 52 old HC were obtained. The ReHo approach was used to analyze the images. The ANOVA analysis revealed that the ReHo values in the frontoparietal, occipital, and cerebellar regions were significantly different among the four groups. Relative to patients with LOD, patients with EOD displayed significantly increased ReHo in the left precuneus, and decreased ReHo in the right fusiform. The ReHo values in the left precuneus and the right fusiform had no significant correlation with the score of the depression rating scale or illness duration in both patient subgroups. Compared to young HC, patients with EOD showed significantly increased ReHo in the right frontoparietal regions and the right calcarine. Furthermore, the increased ReHo in the right frontoparietal regions, right insula and left hippocampus, and decreased ReHo in the left inferior occipital gyrus, right middle occipital gyrus, left calcarine, and left supplementary motor area were observed in patients with LOD when compared to old HC. The ReHo of brain areas that were related to mood regulation was changed in the first-episode, drug-naive adult patients with MDD. Adult patients with EOD and LOD exhibited different ReHo abnormalities relative to each age-matched comparison group, suggesting that depressed adult patients with different age-onset might have different pathological mechanism.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-05
... was required for gas chromatography with mass selective detection (GC/MSD) but not for liquid... detection (LOD = 0.01) and a gas liquid chromatography (GLC) method with a flame photometric detection (LOD... quantification by high performance liquid chromatography with tandem mass spectrometric detection (HPLC/MS/MS...
NASA Astrophysics Data System (ADS)
Williams, Ammon Ned
The primary objective of this research is to develop an applied technology and provide an assessment for remotely measuring and analyzing the real time or near real time concentrations of used nuclear fuel (UNF) elements in electroreners (ER). Here, Laser-Induced Breakdown Spectroscopy (LIBS) in UNF pyroprocessing facilities was investigated. LIBS is an elemental analysis method, which is based on the emission from plasma generated by focusing a laser beam into the medium. This technology has been reported to be applicable in solids, liquids (includes molten metals), and gases for detecting elements of special nuclear materials. The advantages of applying the technology for pyroprocessing facilities are: (i) Rapid real-time elemental analysis; (ii) Direct detection of elements and impurities in the system with low limits of detection (LOD); and (iii) Little to no sample preparation is required. One important challenge to overcome is achieving reproducible spectral data over time while being able to accurately quantify fission products, rare earth elements, and actinides in the molten salt. Another important challenge is related to the accessibility of molten salt, which is heated in a heavily insulated, remotely operated furnace in a high radiation environment within an argon gas atmosphere. This dissertation aims to address these challenges and approaches in the following phases with their highlighted outcomes: 1. Aerosol-LIBS system design and aqueous testing: An aerosol-LIBS system was designed around a Collison nebulizer and tested using deionized water with Ce, Gd, and Nd concentrations from 100 ppm to 10,000 ppm. The average %RSD values between the sample repetitions were 4.4% and 3.8% for the Ce and Gd lines, respectively. The univariate calibration curve for Ce using the peak intensities of the Ce 418.660 nm line was recommended and had an R 2 value, LOD, and RMSECV of 0.994, 189 ppm, and 390 ppm, respectively. The recommended Gd calibration curve was generated using the peak areas of the Gd 409.861 nm line and had an R2, LOD, and RMSECV of 0.992, 316 ppm, and 421 ppm, respectively. The partial least squares (PLS) calibration curves yielded similar results with RMSECV of 406 ppm and 417 ppm for the Ce and Gd curves, respectively. 2. High temperature aerosol-LIBS system design and CeCl3 testing: The aerosol-LIBS system was transitioned to a high temperature and used to measure Ce in molten LiCl-KCl salt within a glovebox environment. The concentration range studied was from 0.1 wt% to 5 wt% Ce. Normalization was necessary due to signal degradation over time; however, with the normalization the %RSD values averaged 5% for the mid and upper concentrations studied. The best univariate calibration curve was generated using the peak areas of the Ce 418.660 nm line. The LOD for this line was 148 ppm with the RMSECV of 647 ppm. The PLS calibration curve was made using 7 latent variables (LV) and resulting in the RMSECV of 622 ppm. The LOD value was below the expected rare earth concentration within the ER. 3. Aerosol-LIBS testing using UCl3: Samples containing UCl 3 with concentrations ranging from 0.3 wt% to 5 wt% were measured. The spectral response in this range was linear. The best univariate calibration curves were generated using the peak areas of the U 367.01 nm line and had an R2 value of 0.9917. Here, the LOD was 647 ppm and the RMSECV was 2,290 ppm. The PLS model was substantially better with a RMSECV of 1,110 ppm. The LOD found here is below the expected U concentrations in the ER. The successful completion of this study has demonstrated the feasibility of using an aerosol-LIBS analytical technique to measure rare earth elements and actinides in the pyroprocessing salt.
Hunter, Margaret; Dorazio, Robert M.; Butterfield, John S.; Meigs-Friend, Gaia; Nico, Leo; Ferrante, Jason A.
2017-01-01
A set of universal guidelines is needed to determine the limit of detection (LOD) in PCR-based analyses of low concentration DNA. In particular, environmental DNA (eDNA) studies require sensitive and reliable methods to detect rare and cryptic species through shed genetic material in environmental samples. Current strategies for assessing detection limits of eDNA are either too stringent or subjective, possibly resulting in biased estimates of species’ presence. Here, a conservative LOD analysis grounded in analytical chemistry is proposed to correct for overestimated DNA concentrations predominantly caused by the concentration plateau, a nonlinear relationship between expected and measured DNA concentrations. We have used statistical criteria to establish formal mathematical models for both quantitative and droplet digital PCR. To assess the method, a new Grass Carp (Ctenopharyngodon idella) TaqMan assay was developed and tested on both PCR platforms using eDNA in water samples. The LOD adjustment reduced Grass Carp occupancy and detection estimates while increasing uncertainty – indicating that caution needs to be applied to eDNA data without LOD correction. Compared to quantitative PCR, digital PCR had higher occurrence estimates due to increased sensitivity and dilution of inhibitors at low concentrations. Without accurate LOD correction, species occurrence and detection probabilities based on eDNA estimates are prone to a source of bias that cannot be reduced by an increase in sample size or PCR replicates. Other applications also could benefit from a standardized LOD such as GMO food analysis, and forensic and clinical diagnostics.
Yoo, Yong Kyoung; Yoon, Dae Sung; Kim, Gangeun; Kim, Jinsik; Han, Sung Il; Lee, Junwoo; Chae, Myung-Sic; Lee, Sang-Myung; Lee, Kyu Hyoung; Hwang, Kyo Seon; Lee, Jeong Hoon
2017-10-30
Sensitivity and limit of detection (LOD) enhancement are essential criteria for the development of ultrasensitive molecular sensors. Although various sensor types have been investigated to enhance sensitivity and LOD, analyte detection and its quantification are still challenging, particularly for protein-protein interactions with low association constants. To solve this problem, here, we used ion concentration polarization (ICP)-based preconcentration to increase the local concentration of analytes in a microfluidic platform for LOD improvement. This was the first demonstration of a microfluidic device with an integrated ICP preconcentrator and interdigitated microelectrode (IME) sensor to detect small changes in surface binding between antigens and antibodies. We detected the amyloid beta (Aβ) protein, an Alzheimer's disease marker, with low binding affinity to its antibodies by adopting ICP preconcentration phenomena. We demonstrated that a combination of ICP preconcentrator and IME sensor increased the LOD by 13.8-fold to femtomolar level (8.15 fM), which corresponds to a significant advance for clinical applications.
Bisphenol A contamination in soft drinks as a risk for children's health in Italy.
Fasano, Evelina; Esposito, Francesco; Scognamiglio, Gelsomina; Di Francesco, Fabio; Montuori, Paolo; Amodio Cocchieri, Renata; Cirillo, Teresa
2015-01-01
Bisphenol A (BPA) was determined in sugary carbonated, non-carbonated and milk-based beverages, through HLPC-fluorescence detection and confirmed by LC-MS/MS, in a selection of brands that are mostly consumed by Italian children. The daily intake was determined through the WHO budget method (BM). BPA was found at detectable levels in 57% of carbonated beverages, in 50% of non-carbonated and in 100% of milk-based beverages. The median concentrations were 1.24 µg l(-1) (range = < LOD-4.98 µg l(-1)) in canned carbonated beverages and 0.18 µg l(-1) (< LOD-1.78 µg l(-1)) in non-canned carbonated beverages. In non-carbonated beverages, median concentrations were 0.80 µg l(-1) (< LOD-2.79 µg l(-1)) and 0.18 µg l(-1) (< LOD-3.58 µg l(-1)), respectively, for canned and non-canned beverages; in milk-based products the BPA median concentration was 3.60 µg l(-1) (1.00-17.65 µg l(-1)). BPA daily intake from sugary drink consumption in children ranged from 0.008 to 1.765 µg kg(-1) bw day(-1). The median exposure values for the 'best' and 'worst' cases were 0.16% and 0.47% respectively of the EFSA t-TDI for BPA (4 µg kg(-1) bw day(-1)), and 10.59% and 35.30% of the t-TDI when the maximum levels were considered.
High-frequency phase shift measurement greatly enhances the sensitivity of QCM immunosensors.
March, Carmen; García, José V; Sánchez, Ángel; Arnau, Antonio; Jiménez, Yolanda; García, Pablo; Manclús, Juan J; Montoya, Ángel
2015-03-15
In spite of being widely used for in liquid biosensing applications, sensitivity improvement of conventional (5-20MHz) quartz crystal microbalance (QCM) sensors remains an unsolved challenging task. With the help of a new electronic characterization approach based on phase change measurements at a constant fixed frequency, a highly sensitive and versatile high fundamental frequency (HFF) QCM immunosensor has successfully been developed and tested for its use in pesticide (carbaryl and thiabendazole) analysis. The analytical performance of several immunosensors was compared in competitive immunoassays taking carbaryl insecticide as the model analyte. The highest sensitivity was exhibited by the 100MHz HFF-QCM carbaryl immunosensor. When results were compared with those reported for 9MHz QCM, analytical parameters clearly showed an improvement of one order of magnitude for sensitivity (estimated as the I50 value) and two orders of magnitude for the limit of detection (LOD): 30μgl(-1) vs 0.66μgL(-1)I50 value and 11μgL(-1) vs 0.14μgL(-1) LOD, for 9 and 100MHz, respectively. For the fungicide thiabendazole, I50 value was roughly the same as that previously reported for SPR under the same biochemical conditions, whereas LOD improved by a factor of 2. The analytical performance achieved by high frequency QCM immunosensors surpassed those of conventional QCM and SPR, closely approaching the most sensitive ELISAs. The developed 100MHz QCM immunosensor strongly improves sensitivity in biosensing, and therefore can be considered as a very promising new analytical tool for in liquid applications where highly sensitive detection is required. Copyright © 2014 Elsevier B.V. All rights reserved.
Highly sensitive lactate biosensor by engineering chitosan/PVI-Os/CNT/LOD network nanocomposite.
Cui, Xiaoqiang; Li, Chang Ming; Zang, Jianfeng; Yu, Shucong
2007-06-15
A novel chitosan/PVI-Os(polyvinylimidazole-Os)/CNT(carbon nanotube)/LOD (lactate oxidase) network nanocomposite was constructed on gold electrode for detection of lactate. The composite was nanoengineered by selected matched material components and optimized composition ratio to produce a superior lactate sensor. Positively charged chitosan and PVI-Os were used as the matrix and the mediator to immobilize the negatively charged LOD and to enhance the electron transfer, respectively. CNTs were introduced as the essential component in the composite for the network nanostructure. FESEM (field emission scan electron microscopy) and electrochemical characterization demonstrated that CNT behaved as a cross-linker to network PVI and chitosan due to its nanoscaled and negative charged nature. This significantly improved the conductivity, stability and electroactivity for detection of lactate. The standard deviation of the sensor without CNT in the composite was greatly reduced from 19.6 to 4.9% by addition of CNTs. With optimized conditions the sensitivity and detection limit of the lactate sensor was 19.7 microA mM(-1)cm(-2) and 5 microM, respectively. The sensitivity was remarkably improved in comparison to the newly reported values of 0.15-3.85 microA mM(-1)cm(-2). This novel nanoengineering approach for selecting matched components to form a network nanostructure could be extended to other enzyme biosensors, and to have broad potential applications in diagnostics, life science and food analysis.
Quantification of type I error probabilities for heterogeneity LOD scores.
Abreu, Paula C; Hodge, Susan E; Greenberg, David A
2002-02-01
Locus heterogeneity is a major confounding factor in linkage analysis. When no prior knowledge of linkage exists, and one aims to detect linkage and heterogeneity simultaneously, classical distribution theory of log-likelihood ratios does not hold. Despite some theoretical work on this problem, no generally accepted practical guidelines exist. Nor has anyone rigorously examined the combined effect of testing for linkage and heterogeneity and simultaneously maximizing over two genetic models (dominant, recessive). The effect of linkage phase represents another uninvestigated issue. Using computer simulation, we investigated type I error (P value) of the "admixture" heterogeneity LOD (HLOD) score, i.e., the LOD score maximized over both recombination fraction theta and admixture parameter alpha and we compared this with the P values when one maximizes only with respect to theta (i.e., the standard LOD score). We generated datasets of phase-known and -unknown nuclear families, sizes k = 2, 4, and 6 children, under fully penetrant autosomal dominant inheritance. We analyzed these datasets (1) assuming a single genetic model, and maximizing the HLOD over theta and alpha; and (2) maximizing the HLOD additionally over two dominance models (dominant vs. recessive), then subtracting a 0.3 correction. For both (1) and (2), P values increased with family size k; rose less for phase-unknown families than for phase-known ones, with the former approaching the latter as k increased; and did not exceed the one-sided mixture distribution xi = (1/2) chi1(2) + (1/2) chi2(2). Thus, maximizing the HLOD over theta and alpha appears to add considerably less than an additional degree of freedom to the associated chi1(2) distribution. We conclude with practical guidelines for linkage investigators. Copyright 2002 Wiley-Liss, Inc.
The score statistic of the LD-lod analysis: detecting linkage adaptive to linkage disequilibrium.
Huang, J; Jiang, Y
2001-01-01
We study the properties of a modified lod score method for testing linkage that incorporates linkage disequilibrium (LD-lod). By examination of its score statistic, we show that the LD-lod score method adaptively combines two sources of information: (a) the IBD sharing score which is informative for linkage regardless of the existence of LD and (b) the contrast between allele-specific IBD sharing scores which is informative for linkage only in the presence of LD. We also consider the connection between the LD-lod score method and the transmission-disequilibrium test (TDT) for triad data and the mean test for affected sib pair (ASP) data. We show that, for triad data, the recessive LD-lod test is asymptotically equivalent to the TDT; and for ASP data, it is an adaptive combination of the TDT and the ASP mean test. We demonstrate that the LD-lod score method has relatively good statistical efficiency in comparison with the ASP mean test and the TDT for a broad range of LD and the genetic models considered in this report. Therefore, the LD-lod score method is an interesting approach for detecting linkage when the extent of LD is unknown, such as in a genome-wide screen with a dense set of genetic markers. Copyright 2001 S. Karger AG, Basel
Lalani, Tahaniyat; Tisdale, Michele D; Maguire, Jason D; Wongsrichanalai, Chansuda; Riddle, Mark S; Tribble, David R
2015-09-01
We evaluated the limits of detection (LoD) for an 11-plex PCR-Luminex assay performed on Whatman(™) FTA Elute cards smeared with stool containing pathogens associated with travelers' diarrhea. LoDs ranged from 10(2) to 10(5)CFU, PFU, or cysts/g for most pathogens except Cryptosporidium. Campylobacter and norovirus LoDs increased with prolonged storage of cards. Copyright © 2015 Elsevier Inc. All rights reserved.
Hunter, Margaret E; Dorazio, Robert M; Butterfield, John S S; Meigs-Friend, Gaia; Nico, Leo G; Ferrante, Jason A
2017-03-01
A set of universal guidelines is needed to determine the limit of detection (LOD) in PCR-based analyses of low-concentration DNA. In particular, environmental DNA (eDNA) studies require sensitive and reliable methods to detect rare and cryptic species through shed genetic material in environmental samples. Current strategies for assessing detection limits of eDNA are either too stringent or subjective, possibly resulting in biased estimates of species' presence. Here, a conservative LOD analysis grounded in analytical chemistry is proposed to correct for overestimated DNA concentrations predominantly caused by the concentration plateau, a nonlinear relationship between expected and measured DNA concentrations. We have used statistical criteria to establish formal mathematical models for both quantitative and droplet digital PCR. To assess the method, a new Grass Carp (Ctenopharyngodon idella) TaqMan assay was developed and tested on both PCR platforms using eDNA in water samples. The LOD adjustment reduced Grass Carp occupancy and detection estimates while increasing uncertainty-indicating that caution needs to be applied to eDNA data without LOD correction. Compared to quantitative PCR, digital PCR had higher occurrence estimates due to increased sensitivity and dilution of inhibitors at low concentrations. Without accurate LOD correction, species occurrence and detection probabilities based on eDNA estimates are prone to a source of bias that cannot be reduced by an increase in sample size or PCR replicates. Other applications also could benefit from a standardized LOD such as GMO food analysis and forensic and clinical diagnostics. Published 2016. This article is a U.S. Government work and is in the public domain in the USA.
Meteorological interpretation of transient LOD changes
NASA Astrophysics Data System (ADS)
Masaki, Y.
2008-04-01
The Earth’s spin rate is mainly changed by zonal winds. For example, seasonal changes in global atmospheric circulation and episodic changes accompanied with El Nĩ os are clearly detected n in the Length-of-day (LOD). Sub-global to regional meteorological phenomena can also change the wind field, however, their effects on the LOD are uncertain because such LOD signals are expected to be subtle and transient. In our previous study (Masaki, 2006), we introduced atmospheric pressure gradients in the upper atmosphere in order to obtain a rough picture of the meteorological features that can change the LOD. In this presentation, we compare one-year LOD data with meteorological elements (winds, temperature, pressure, etc.) and make an attempt to link transient LOD changes with sub-global meteorological phenomena.
Campbell, Keri R.; Judge, Elizabeth J.; Barefield, James E.; ...
2017-04-22
We show the analysis of light water reactor simulated used nuclear fuel using laser-induced breakdown spectroscopy (LIBS) is explored using a simplified version of the main oxide phase. The main oxide phase consists of the actinides, lanthanides, and zirconium. The purpose of this study is to develop a rapid, quantitative technique for measuring zirconium in a uranium dioxide matrix without the need to dissolve the material. A second set of materials including cerium oxide is also analyzed to determine precision and limit of detection (LOD) using LIBS in a complex matrix. Two types of samples are used in this study:more » binary and ternary oxide pellets. The ternary oxide, (U,Zr,Ce)O 2 pellets used in this study are a simplified version the main oxide phase of used nuclear fuel. The binary oxides, (U,Ce)O 2 and (U,Zr)O 2 are also examined to determine spectral emission lines for Ce and Zr, potential spectral interferences with uranium and baseline LOD values for Ce and Zr in a UO 2 matrix. In the spectral range of 200 to 800 nm, 33 cerium lines and 25 zirconium lines were identified and shown to have linear correlation values (R 2) > 0.97 for both the binary and ternary oxides. The cerium LOD in the (U,Ce)O 2 matrix ranged from 0.34 to 1.08 wt% and 0.94 to 1.22 wt% in (U,Ce,Zr)O 2 for 33 of Ce emission lines. The zirconium limit of detection in the (U,Zr)O 2 matrix ranged from 0.84 to 1.15 wt% and 0.99 to 1.10 wt% in (U,Ce,Zr)O 2 for 25 Zr lines. Finally, the effect of multiple elements in the plasma and the impact on the LOD is discussed.« less
Xiong, Ling-Hong; He, Xuewen; Xia, Junjie; Ma, Hanwu; Yang, Fan; Zhang, Qian; Huang, Dana; Chen, Long; Wu, Chunli; Zhang, Xiaomin; Zhao, Zheng; Wan, Chengsong; Zhang, Renli; Cheng, Jinquan
2017-05-03
Development of sensitive, convenient, and cost-effective virus detection product is of great significance to meet the growing demand of clinical diagnosis at the early stage of virus infection. Herein, a naked-eye readout of immunoassay by means of virion bridged catalase-mediated in situ reduction of gold ions and growth of nanoparticles, has been successfully proposed for rapid visual detection of Enterovirus 71 (EV71). Through tailoring the morphologies of the produced gold nanoparticles (GNPs) varying between dispersion and aggregation, a distinguishing color changing was ready for observation. This colorimetric detection assay, by further orchestrating the efficient magnetic enrichment and the high catalytic activity of enzyme, is managed to realize highly sensitive detection of EV71 virions with the limit of detection (LOD) down to 0.65 ng/mL. Our proposed method showed a much lower LOD value than the commercial ELISA for EV71 virion detection. Comparing to the current clinical gold standard polymerase chain reaction (PCR) method, our strategy provided the same diagnostic outcomes after testing real clinical samples. Besides, this strategy has no need of complicated sample pretreatment or expensive instruments. Our presented naked-eye immunoassay method holds a promising prospect for the early detection of virus-infectious disease especially in resource-constrained settings.
NASA Astrophysics Data System (ADS)
Laville, Stéphane; Goueguel, Christian; Loudyi, Hakim; Vidal, François; Chaker, Mohamed; Sabsabi, Mohamad
2009-04-01
The combination of the laser-induced breakdown spectroscopy (LIBS) and laser-induced fluorescence (LIF) techniques was investigated to improve the limit of detection (LoD) of trace elements in solid matrices. The influence of the main experimental parameters on the LIF signal, namely the ablation fluence, the excitation energy, and the inter-pulse delay, was studied experimentally and a discussion of the results was presented. For illustrative purpose we considered detection of lead in brass samples. The plasma was produced by a Q-switched Nd:YAG laser and then re-excited by a nanosecond Optical Parametric Oscillator (OPO) laser. The experiments were performed in air at atmospheric pressure. We found out that the optimal conditions were obtained for our experimental set-up using relatively weak ablation fluence of 2-3 J/cm 2 and an inter-pulse delay of about 5-10 μs. Also, a few tens of microjoules was typically required to maximize the LIF signal. Using the LIBS-LIFS technique, a single-shot LoD for lead of about 1.5 part per million (ppm) was obtained while a value of 0.2 ppm was obtained after accumulating over 100 shots. These values represent an improvement of about two orders of magnitude with respect to LIBS.
Using lod scores to detect sex differences in male-female recombination fractions.
Feenstra, B; Greenberg, D A; Hodge, S E
2004-01-01
Human recombination fraction (RF) can differ between males and females, but investigators do not always know which disease genes are located in genomic areas of large RF sex differences. Knowledge of RF sex differences contributes to our understanding of basic biology and can increase the power of a linkage study, improve gene localization, and provide clues to possible imprinting. One way to detect these differences is to use lod scores. In this study we focused on detecting RF sex differences and answered the following questions, in both phase-known and phase-unknown matings: (1) How large a sample size is needed to detect a RF sex difference? (2) What are "optimal" proportions of paternally vs. maternally informative matings? (3) Does ascertaining nonoptimal proportions of paternally or maternally informative matings lead to ascertainment bias? Our results were as follows: (1) We calculated expected lod scores (ELODs) under two different conditions: "unconstrained," allowing sex-specific RF parameters (theta(female), theta(male)); and "constrained," requiring theta(female) = theta(male). We then examined the DeltaELOD (identical with difference between maximized constrained and unconstrained ELODs) and calculated minimum sample sizes required to achieve statistically significant DeltaELODs. For large RF sex differences, samples as small as 10 to 20 fully informative matings can achieve statistical significance. We give general sample size guidelines for detecting RF differences in informative phase-known and phase-unknown matings. (2) We defined p as the proportion of paternally informative matings in the dataset; and the optimal proportion p(circ) as that value of p that maximizes DeltaELOD. We determined that, surprisingly, p(circ) does not necessarily equal (1/2), although it does fall between approximately 0.4 and 0.6 in most situations. (3) We showed that if p in a sample deviates from its optimal value, no bias is introduced (asymptotically) to the maximum likelihood estimates of theta(female) and theta(male), even though ELOD is reduced (see point 2). This fact is important because often investigators cannot control the proportions of paternally and maternally informative families. In conclusion, it is possible to reliably detect sex differences in recombination fraction. Copyright 2004 S. Karger AG, Basel
The Use and Abuse of Limits of Detection in Environmental Analytical Chemistry
Brown, Richard J. C.
2008-01-01
The limit of detection (LoD) serves as an important method performance measure that is useful for the comparison of measurement techniques and the assessment of likely signal to noise performance, especially in environmental analytical chemistry. However, the LoD is only truly related to the precision characteristics of the analytical instrument employed for the analysis and the content of analyte in the blank sample. This article discusses how other criteria, such as sampling volume, can serve to distort the quoted LoD artificially and make comparison between various analytical methods inequitable. In order to compare LoDs between methods properly, it is necessary to state clearly all of the input parameters relating to the measurements that have been used in the calculation of the LoD. Additionally, the article discusses that the use of LoDs in contexts other than the comparison of the attributes of analytical methods, in particular when reporting analytical results, may be confusing, less informative than quoting the actual result with an accompanying statement of uncertainty, and may act to bias descriptive statistics. PMID:18690384
Dubé, M P; Mlodzienski, M A; Kibar, Z; Farlow, M R; Ebers, G; Harper, P; Kolodny, E H; Rouleau, G A; Figlewicz, D A
1997-03-01
Hereditary spastic paraplegia (HSP) is a degenerative disorder of the motor system, defined by progressive weakness and spasticity of the lower limbs. HSP may be inherited as an autosomal dominant (AD), autosomal recessive, or an X-linked trait. AD HSP is genetically heterogeneous, and three loci have been identified so far: SPG3 maps to chromosome 14q, SPG4 to 2p, and SPG4a to 15q. We have undertaken linkage analysis with 21 uncomplicated AD families to the three AD HSP loci. We report significant linkage for three of our families to the SPG4 locus and exclude several families by multipoint linkage. We used linkage information from several different research teams to evaluate the statistical probability of linkage to the SPG4 locus for uncomplicated AD HSP families and established the critical LOD-score value necessary for confirmation of linkage to the SPG4 locus from Bayesian statistics. In addition, we calculated the empirical P-values for the LOD scores obtained with all families with computer simulation methods. Power to detect significant linkage, as well as type I error probabilities, were evaluated. This combined analytical approach permitted conclusive linkage analyses on small to medium-size families, under the restrictions of genetic heterogeneity.
Large-scale femtoliter droplet array for digital counting of single biomolecules.
Kim, Soo Hyeon; Iwai, Shino; Araki, Suguru; Sakakihara, Shouichi; Iino, Ryota; Noji, Hiroyuki
2012-12-07
We present a novel device employing one million femtoliter droplets immobilized on a substrate for the quantitative detection of extremely low concentrations of biomolecules in a sample. Surface-modified polystyrene beads carrying either zero or a single biomolecule-reporter enzyme complex are efficiently isolated into femtoliter droplets formed on hydrophilic-in-hydrophobic surfaces. Using a conventional micropipette, this is achieved by sequential injection first with an aqueous solution containing beads, and then with fluorinated oil. The concentration of target biomolecules is estimated from the ratio of the number of signal-emitting droplets to the total number of trapped beads (digital counting). The performance of our digital counting device was demonstrated by detecting a streptavidin-β-galactosidase conjugate with a limit of detection (LOD) of 10 zM. The sensitivity of our device was >20-fold higher than that noted in previous studies where a smaller number of reactors (fifty thousand reactors) were used. Such a low LOD was achieved because of the large number of droplets in an array, allowing simultaneous examination of a large number of beads. When combined with bead-based enzyme-linked immunosorbent assay (digital ELISA), the LOD for the detection of prostate specific antigen reached 2 aM. This value, again, was improved over that noted in a previous study, because of the decreased coefficient of variance of the background measurement determined by the Poisson noise. Our digital counting device using one million droplets has great potential as a highly sensitive, portable immunoassay device that could be used to diagnose diseases.
Stokdyk, Joel P; Firnstahl, Aaron D; Spencer, Susan K; Burch, Tucker R; Borchardt, Mark A
2016-06-01
The limit of detection (LOD) for qPCR-based analyses is not consistently defined or determined in studies on waterborne pathogens. Moreover, the LODs reported often reflect the qPCR assay alone rather than the entire sample process. Our objective was to develop an approach to determine the 95% LOD (lowest concentration at which 95% of positive samples are detected) for the entire process of waterborne pathogen detection. We began by spiking the lowest concentration that was consistently positive at the qPCR step (based on its standard curve) into each procedural step working backwards (i.e., extraction, secondary concentration, primary concentration), which established a concentration that was detectable following losses of the pathogen from processing. Using the fraction of positive replicates (n = 10) at this concentration, we selected and analyzed a second, and then third, concentration. If the fraction of positive replicates equaled 1 or 0 for two concentrations, we selected another. We calculated the LOD using probit analysis. To demonstrate our approach we determined the 95% LOD for Salmonella enterica serovar Typhimurium, adenovirus 41, and vaccine-derived poliovirus Sabin 3, which were 11, 12, and 6 genomic copies (gc) per reaction (rxn), respectively (equivalent to 1.3, 1.5, and 4.0 gc L(-1) assuming the 1500 L tap-water sample volume prescribed in EPA Method 1615). This approach limited the number of analyses required and was amenable to testing multiple genetic targets simultaneously (i.e., spiking a single sample with multiple microorganisms). An LOD determined this way can facilitate study design, guide the number of required technical replicates, aid method evaluation, and inform data interpretation. Published by Elsevier Ltd.
Stokdyk, Joel P.; Firnstahl, Aaron; Spencer, Susan K.; Burch, Tucker R; Borchardt, Mark A.
2016-01-01
The limit of detection (LOD) for qPCR-based analyses is not consistently defined or determined in studies on waterborne pathogens. Moreover, the LODs reported often reflect the qPCR assay alone rather than the entire sample process. Our objective was to develop an approach to determine the 95% LOD (lowest concentration at which 95% of positive samples are detected) for the entire process of waterborne pathogen detection. We began by spiking the lowest concentration that was consistently positive at the qPCR step (based on its standard curve) into each procedural step working backwards (i.e., extraction, secondary concentration, primary concentration), which established a concentration that was detectable following losses of the pathogen from processing. Using the fraction of positive replicates (n = 10) at this concentration, we selected and analyzed a second, and then third, concentration. If the fraction of positive replicates equaled 1 or 0 for two concentrations, we selected another. We calculated the LOD using probit analysis. To demonstrate our approach we determined the 95% LOD for Salmonella enterica serovar Typhimurium, adenovirus 41, and vaccine-derived poliovirus Sabin 3, which were 11, 12, and 6 genomic copies (gc) per reaction (rxn), respectively (equivalent to 1.3, 1.5, and 4.0 gc L−1 assuming the 1500 L tap-water sample volume prescribed in EPA Method 1615). This approach limited the number of analyses required and was amenable to testing multiple genetic targets simultaneously (i.e., spiking a single sample with multiple microorganisms). An LOD determined this way can facilitate study design, guide the number of required technical replicates, aid method evaluation, and inform data interpretation.
Greenslade, J H; Kavsak, P; Parsonage, W; Shortt, C; Than, M; Pickering, J W; Aldous, S; Cullen, L
2015-03-01
The use of high sensitivity troponin (hs-Tn) may enable early rule out of acute myocardial infarction (AMI) for patients presenting to the emergency department (ED) with chest pain. This study evaluated two approaches to the early rule out of AMI; a combination of a presentation hs-Tn <4ng/L and normal glucose at presentation (dual testing) and a presentation hs-Tn troponin below the limit of detection (LoD). We utilised prospectively collected data on adult patients presenting with suspected ACS in two EDs in Australia and New Zealand. Blood samples were taken on presentation and tested for glucose and high sensitivity troponin I. The primary endpoint was index AMI and the secondary endpoint was 30-day acute coronary syndrome (ACS). Sensitivity, specificity, positive and negative predictive values were used to assess the diagnostic accuracy of the dual testing and LoD approaches. Of the 1412 participants, 182 (12.9%) had index AMI. The LoD and the dual testing approach were 100% sensitive for index AMI. The specificity of the dual testing approach (25.2%) was slightly higher than that of the LoD (20.4%). Sensitivity for ACS was similar for the two approaches (96.5% for dual testing and 98.1% for the LoD). The dual testing and LoD approach identified all patients with index AMI and could be used to reduce the proportion of patients requiring lengthy assessment and inpatient admission. Further investigation is still required to rule out unstable angina pectoris in patients identified as low risk. Copyright © 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Quantile-based permutation thresholds for quantitative trait loci hotspots.
Neto, Elias Chaibub; Keller, Mark P; Broman, Andrew F; Attie, Alan D; Jansen, Ritsert C; Broman, Karl W; Yandell, Brian S
2012-08-01
Quantitative trait loci (QTL) hotspots (genomic locations affecting many traits) are a common feature in genetical genomics studies and are biologically interesting since they may harbor critical regulators. Therefore, statistical procedures to assess the significance of hotspots are of key importance. One approach, randomly allocating observed QTL across the genomic locations separately by trait, implicitly assumes all traits are uncorrelated. Recently, an empirical test for QTL hotspots was proposed on the basis of the number of traits that exceed a predetermined LOD value, such as the standard permutation LOD threshold. The permutation null distribution of the maximum number of traits across all genomic locations preserves the correlation structure among the phenotypes, avoiding the detection of spurious hotspots due to nongenetic correlation induced by uncontrolled environmental factors and unmeasured variables. However, by considering only the number of traits above a threshold, without accounting for the magnitude of the LOD scores, relevant information is lost. In particular, biologically interesting hotspots composed of a moderate to small number of traits with strong LOD scores may be neglected as nonsignificant. In this article we propose a quantile-based permutation approach that simultaneously accounts for the number and the LOD scores of traits within the hotspots. By considering a sliding scale of mapping thresholds, our method can assess the statistical significance of both small and large hotspots. Although the proposed approach can be applied to any type of heritable high-volume "omic" data set, we restrict our attention to expression (e)QTL analysis. We assess and compare the performances of these three methods in simulations and we illustrate how our approach can effectively assess the significance of moderate and small hotspots with strong LOD scores in a yeast expression data set.
Horne, Benjamin D; Malhotra, Alka; Camp, Nicola J
2003-01-01
Background High triglycerides (TG) and low high-density lipoprotein cholesterol (HDL-C) jointly increase coronary disease risk. We performed linkage analysis for TG/HDL-C ratio in the Framingham Heart Study data as a quantitative trait, using methods implemented in LINKAGE, GENEHUNTER (GH), MCLINK, and SOLAR. Results were compared to each other and to those from a previous evaluation using SOLAR for TG/HDL-C ratio on this sample. We also investigated linked pedigrees in each region using by-pedigree analysis. Results Fourteen regions with at least suggestive linkage evidence were identified, including some that may increase and some that may decrease coronary risk. Ten of the 14 regions were identified by more than one analysis, and several of these regions were not previously detected. The best regions identified for each method were on chromosomes 2 (LOD = 2.29, MCLINK), 5 (LOD = 2.65, GH), 7 (LOD = 2.67, SOLAR), and 22 (LOD = 3.37, LINKAGE). By-pedigree multi-point LOD values in MCLINK showed linked pedigrees for all five regions, ranging from 3 linked pedigrees (chromosome 5) to 14 linked pedigrees (chromosome 7), and suggested localizations of between 9 cM and 27 cM in size. Conclusion Reasonable concordance was found across analysis methods. No single method identified all regions, either by full sample LOD or with by-pedigree analysis. Concordance across methods appeared better at the pedigree level, with many regions showing by-pedigree support in MCLINK when no evidence was observed in the full sample. Thus, investigating by-pedigree linkage evidence may provide a useful tool for evaluating linkage regions. PMID:14975161
Horne, Benjamin D; Malhotra, Alka; Camp, Nicola J
2003-12-31
High triglycerides (TG) and low high-density lipoprotein cholesterol (HDL-C) jointly increase coronary disease risk. We performed linkage analysis for TG/HDL-C ratio in the Framingham Heart Study data as a quantitative trait, using methods implemented in LINKAGE, GENEHUNTER (GH), MCLINK, and SOLAR. Results were compared to each other and to those from a previous evaluation using SOLAR for TG/HDL-C ratio on this sample. We also investigated linked pedigrees in each region using by-pedigree analysis. Fourteen regions with at least suggestive linkage evidence were identified, including some that may increase and some that may decrease coronary risk. Ten of the 14 regions were identified by more than one analysis, and several of these regions were not previously detected. The best regions identified for each method were on chromosomes 2 (LOD = 2.29, MCLINK), 5 (LOD = 2.65, GH), 7 (LOD = 2.67, SOLAR), and 22 (LOD = 3.37, LINKAGE). By-pedigree multi-point LOD values in MCLINK showed linked pedigrees for all five regions, ranging from 3 linked pedigrees (chromosome 5) to 14 linked pedigrees (chromosome 7), and suggested localizations of between 9 cM and 27 cM in size. Reasonable concordance was found across analysis methods. No single method identified all regions, either by full sample LOD or with by-pedigree analysis. Concordance across methods appeared better at the pedigree level, with many regions showing by-pedigree support in MCLINK when no evidence was observed in the full sample. Thus, investigating by-pedigree linkage evidence may provide a useful tool for evaluating linkage regions.
Amin, Najaf; Hottenga, Jouke-Jan; Hansell, Narelle K; Janssens, A Cecile JW; de Moor, Marleen HM; Madden, Pamela AF; Zorkoltseva, Irina V; Penninx, Brenda W; Terracciano, Antonio; Uda, Manuela; Tanaka, Toshiko; Esko, Tonu; Realo, Anu; Ferrucci, Luigi; Luciano, Michelle; Davies, Gail; Metspalu, Andres; Abecasis, Goncalo R; Deary, Ian J; Raikkonen, Katri; Bierut, Laura J; Costa, Paul T; Saviouk, Viatcheslav; Zhu, Gu; Kirichenko, Anatoly V; Isaacs, Aaron; Aulchenko, Yurii S; Willemsen, Gonneke; Heath, Andrew C; Pergadia, Michele L; Medland, Sarah E; Axenovich, Tatiana I; de Geus, Eco; Montgomery, Grant W; Wright, Margaret J; Oostra, Ben A; Martin, Nicholas G; Boomsma, Dorret I; van Duijn, Cornelia M
2013-01-01
Personality traits are complex phenotypes related to psychosomatic health. Individually, various gene finding methods have not achieved much success in finding genetic variants associated with personality traits. We performed a meta-analysis of four genome-wide linkage scans (N=6149 subjects) of five basic personality traits assessed with the NEO Five-Factor Inventory. We compared the significant regions from the meta-analysis of linkage scans with the results of a meta-analysis of genome-wide association studies (GWAS) (N∼17 000). We found significant evidence of linkage of neuroticism to chromosome 3p14 (rs1490265, LOD=4.67) and to chromosome 19q13 (rs628604, LOD=3.55); of extraversion to 14q32 (ATGG002, LOD=3.3); and of agreeableness to 3p25 (rs709160, LOD=3.67) and to two adjacent regions on chromosome 15, including 15q13 (rs970408, LOD=4.07) and 15q14 (rs1055356, LOD=3.52) in the individual scans. In the meta-analysis, we found strong evidence of linkage of extraversion to 4q34, 9q34, 10q24 and 11q22, openness to 2p25, 3q26, 9p21, 11q24, 15q26 and 19q13 and agreeableness to 4q34 and 19p13. Significant evidence of association in the GWAS was detected between openness and rs677035 at 11q24 (P-value=2.6 × 10−06, KCNJ1). The findings of our linkage meta-analysis and those of the GWAS suggest that 11q24 is a susceptible locus for openness, with KCNJ1 as the possible candidate gene. PMID:23211697
Galievsky, Victor A; Stasheuski, Alexander S; Krylov, Sergey N
2017-10-17
The limit-of-detection (LOD) in analytical instruments with fluorescence detection can be improved by reducing noise of optical background. Efficiently reducing optical background noise in systems with spectrally nonuniform background requires complex optimization of an emission filter-the main element of spectral filtration. Here, we introduce a filter-optimization method, which utilizes an expression for the signal-to-noise ratio (SNR) as a function of (i) all noise components (dark, shot, and flicker), (ii) emission spectrum of the analyte, (iii) emission spectrum of the optical background, and (iv) transmittance spectrum of the emission filter. In essence, the noise components and the emission spectra are determined experimentally and substituted into the expression. This leaves a single variable-the transmittance spectrum of the filter-which is optimized numerically by maximizing SNR. Maximizing SNR provides an accurate way of filter optimization, while a previously used approach based on maximizing a signal-to-background ratio (SBR) is the approximation that can lead to much poorer LOD specifically in detection of fluorescently labeled biomolecules. The proposed filter-optimization method will be an indispensable tool for developing new and improving existing fluorescence-detection systems aiming at ultimately low LOD.
Conclusion of LOD-score analysis for family data generated under two-locus models.
Dizier, M H; Babron, M C; Clerget-Darpoux, F
1996-06-01
The power to detect linkage by the LOD-score method is investigated here for diseases that depend on the effects of two genes. The classical strategy is, first, to detect a major-gene (MG) effect by segregation analysis and, second, to seek for linkage with genetic markers by the LOD-score method using the MG parameters. We already showed that segregation analysis can lead to evidence for a MG effect for many two-locus models, with the estimates of the MG parameters being very different from those of the two genes involved in the disease. We show here that use of these MG parameter estimates in the LOD-score analysis may lead to a failure to detect linkage for some two-locus models. For these models, use of the sib-pair method gives a non-negligible increase of power to detect linkage. The linkage-homogeneity test among subsamples differing for the familial disease distribution provides evidence of parameter misspecification, when the MG parameters are used. Moreover, for most of the models, use of the MG parameters in LOD-score analysis leads to a large bias in estimation of the recombination fraction and sometimes also to a rejection of linkage for the true recombination fraction. A final important point is that a strong evidence of an MG effect, obtained by segregation analysis, does not necessarily imply that linkage will be detected for at least one of the two genes, even with the true parameters and with a close informative marker.
Estimation of the Length of Day (LOD) from DORIS observations
NASA Astrophysics Data System (ADS)
Štěpánek, Petr; Hugentobler, Urs; Buday, Michal; Filler, Vratislav
2018-07-01
The paper is devoted to the estimation of the Length of the Day (LOD) from DORIS observations and summarizes the first successful experiment with LOD estimation at the level of geodetic precision. This result is confirmed by 9 years of DORIS data (2006.0-2015.0). The mean difference of the non smoothed LOD series with respect to the IERS C04 model reaches a value of tens μs and a standard deviation around 120 μs for the last years of the campaign 2012.0-2015.0. However, the mean difference with respect to the reference model varies over time, reaching negative values from -60 to -20 μs for the years 2006-2011 and positive values from 80 to 120 μs for the years 2012-2014. The time variable mean difference with respect to the changes in DORIS satellite constellation is discussed, as well as the possibility of the bias reduction applying the long-term averages of the cross-track harmonics or adjustment of the geopotential coefficient C20. Moreover, the possibility of LOD adjustment in the standard DORIS solution is discussed with focus on the station coordinates estimation. In addition, the power spectrum of the difference between estimated LOD and the reference model was performed, showing the domination of the annual signal. Also LOD estimated from single-satellite DORIS solutions was analyzed to identify satellite-specific issues. The paper includes a correlation analysis of the orbit parameters, Earth rotation parameters and the geopotential coefficient C20, based on covariance matrices from weekly solutions. High correlation around 0.96 was found for LOD and the sine amplitude of the cross-track harmonic empirical acceleration, which was also confirmed analytically.
Gergov, M; Ojanperä, I; Vuori, E
2003-09-25
A liquid chromatography-tandem mass spectrometry (LC-MS-MS) method is presented for the qualitative screening for 238 drugs in blood samples, which is considerably more than in previous methods. After a two-step liquid-liquid extraction and C(18) chromatography, the compounds were introduced into a triple quadrupole mass spectrometer equipped with a turbo ion spray ion source operating in the positive ionization mode. Identification was based on the compound's absolute retention time, protonated molecular ion, and one representative fragment ion obtained by multiple reaction monitoring (MRM) at an individually selected collision energy of 20, 35, or 50 eV. The limit of detection (LOD) for the majority of the compounds (80%) was < or = 0.05 mg/l, ranging from 0.002 mg/l (e.g., antihistamines) to 5 mg/l (acidic compounds), and for malathion it was 10 mg/l. The LOD values were sufficiently low to allow the majority of compounds to be detected at therapeutic concentrations in the blood.
Targeted Analyte Detection by Standard Addition Improves Detection Limits in MALDI Mass Spectrometry
Eshghi, Shadi Toghi; Li, Xingde; Zhang, Hui
2014-01-01
Matrix-assisted laser desorption/ionization has proven an effective tool for fast and accurate determination of many molecules. However, the detector sensitivity and chemical noise compromise the detection of many invaluable low-abundance molecules from biological and clinical samples. To challenge this limitation, we developed a targeted analyte detection (TAD) technique. In TAD, the target analyte is selectively elevated by spiking a known amount of that analyte into the sample, thereby raising its concentration above the noise level, where we take advantage of the improved sensitivity to detect the presence of the endogenous analyte in the sample. We assessed TAD on three peptides in simple and complex background solutions with various exogenous analyte concentrations in two MALDI matrices. TAD successfully improved the limit of detection (LOD) of target analytes when the target peptides were added to the sample in a concentration close to optimum concentration. The optimum exogenous concentration was estimated through a quantitative method to be approximately equal to the original LOD for each target. Also, we showed that TAD could achieve LOD improvements on an average of 3-fold in a simple and 2-fold in a complex sample. TAD provides a straightforward assay to improve the LOD of generic target analytes without the need for costly hardware modifications. PMID:22877355
Toghi Eshghi, Shadi; Li, Xingde; Zhang, Hui
2012-09-18
Matrix-assisted laser desorption/ionization (MALDI) has proven an effective tool for fast and accurate determination of many molecules. However, the detector sensitivity and chemical noise compromise the detection of many invaluable low-abundance molecules from biological and clinical samples. To challenge this limitation, we developed a targeted analyte detection (TAD) technique. In TAD, the target analyte is selectively elevated by spiking a known amount of that analyte into the sample, thereby raising its concentration above the noise level, where we take advantage of the improved sensitivity to detect the presence of the endogenous analyte in the sample. We assessed TAD on three peptides in simple and complex background solutions with various exogenous analyte concentrations in two MALDI matrices. TAD successfully improved the limit of detection (LOD) of target analytes when the target peptides were added to the sample in a concentration close to optimum concentration. The optimum exogenous concentration was estimated through a quantitative method to be approximately equal to the original LOD for each target. Also, we showed that TAD could achieve LOD improvements on an average of 3-fold in a simple and 2-fold in a complex sample. TAD provides a straightforward assay to improve the LOD of generic target analytes without the need for costly hardware modifications.
Plucinski, Mateusz M; Rogier, Eric; Dimbu, Pedro Rafael; Fortes, Filomeno; Halsey, Eric S; Aidoo, Michael
2017-10-01
Most malaria testing is by rapid diagnostic tests (RDTs) that detect Plasmodium falciparum histidine-rich protein 2 (HRP2). Recently, several RDT manufacturers have developed highly sensitive RDTs (hsRDTs), promising a limit of detection (LOD) orders of magnitude lower than conventional RDTs. To model the added utility of hsRDTs, HRP2 concentration in Angolan outpatients was measured quantitatively using an ultrasensitive bead-based assay. The distribution of HRP2 concentration was bimodal in both afebrile and febrile patients. The conventional RDT was able to detect 81% of all HRP2-positive febrile patients and 52-77% of HRP2-positive afebrile patients. The added utility of hsRDTs was estimated to be greater in afebrile patients, where an hsRDT with a LOD of 200 pg/mL would detect an additional 50-60% of HRP2-positive persons compared with a conventional RDT with a LOD of 3,000 pg/mL. In febrile patients, the hsRDT would detect an additional 10-20% of cases. Conventional RDTs already capture the vast majority of symptomatic HRP2-positive individuals, and hsRDTs would have to reach a sufficiently low LOD approaching 200 pg/mL to provide added utility in identifying HRP2-positive, asymptomatic individuals.
Manibalan, Kesavan; Mani, Veerappan; Huang, Chih-Hung; Huang, Sheng-Tung; Chang, Pu-Chieh
2015-09-07
A 4-Methoxyphenyl-β-galactopyranoside (4-MPGal) substrate incorporating 4-methoxy phenol (4-MP) as an electrochemical reporter is described for the monitoring of β-Galactosidase (β-Gal) gene expressions. β-Gal derived from Escherichia coli (E. coli) and Aspergillus oryzae (A. oryzae) were investigated, while a graphene oxide film modified electrode was employed as the transducer. The electrochemical signal of 4-MPG within 4-MPGal was masked by protecting their hydroxyl group with galactose. The externally added β-Gal triggered the deprotection through specific enzymatic hydrolysis with concomitant release of 4-MP. The apparent Km and Vmax values of 4-MPGal are determined to be 0.21 mM and 0.51 μM min(-1) mg of β-Gal(-1) (E. coli), which is consistent with the previous reports. To detect β-Gal derived from E. coli, cyclic voltammetry (CV) provides linear ranges of 12-1200 ng mL(-1) and 1.2-12 μg mL(-1) with a limit of detection (LOD) of 5 ng mL(-1), while differential pulse voltammetry (DPV) shows a linear range of 1.2-120 ng mL(-1) and LOD of 1 ng mL(-1). To detect β-Gal derived from A. oryzae, CV provides linear ranges of 0.1-100 ng mL(-1) and 0.1-1 μg mL(-1) with a LOD of 0.06 ng mL(-1), while DPV shows a linear range of 10 pg mL(-1)-10 ng mL(-1) with a LOD of 8 pg mL(-1). Moreover, we set up a platform for the real-time in vivo monitoring of β-Gal gene expressions in E. coli cultivated through microbiological culture. The developed sensing platform using 4-MPGal as a substrate is simple, rapid, sensitive, specific and advantageous over its laborious optical analogues.
Nkabinde, Sylvia N; Okonkwo, Jonathan O; Olukunle, Olubiyi I; Daso, Adegbenro P
2018-05-01
Indoor dust is known to be a source of human exposure to brominated flame retardants (BFRs) and these consists of the legacy polybrominated diphenyl ethers (PBDEs), total hexabromocyclododecane (T-HBCDD) and the "Novel or alternate" Brominated flame retardants (NBFRs). In this study, x-ray fluorescence (XRF) analyser was employed to measure elemental bromine contents in office furniture and electronics as the first indication of the possible presence of BFRs. To investigate the possible BFRs present, a total of 21 dust samples were collected from surfaces of electronic equipment and office furniture and were analysed using gas chromatography-mass spectrometry (GC-MS). The concentrations of ∑ 7 BDE- congeners ranged from 50 to 3346ngng -1 . Of the ∑ 7 BDE congeners analysed, BDE-209, -183 and -99 were the most dominant congeners. The concentrations observed ranged from
Tan, Weiming; Huang, Yuan; Nan, Tiegui; Xue, Changguo; Li, Zhaohu; Zhang, Qingchuan; Wang, Baomin
2010-01-15
Development of microcantilever biosensors for small molecules was exemplified with the beta-adrenergic agonist clenbuterol and the antibiotic chloramphenicol. In this paper, antibody sulfhydrylation and protein A were used to modify the microcantilever Au surface, and the antibody activities on the microcantilever were evaluated with direct competitive enzyme-linked immunosorbent assay (dcELISA). The activity of the antibodies immobilized on the microcantilever via protein A was 1.7-fold of that via the sulfhydrylation reagent 2-iminothiolane hydrochloride. A microcantilever immunosensor method with protein A as the functionalization reagent was established to detect the residues of clenbuterol and chloramphenicol at limits of detection (LOD) of approximately 0.1 and 0.2 ng/mL, respectively. Such LODs were better than that of the corresponding dcELISAs. The concentration of clenbuterol in a fortified feed sample detected with the microcantilever immunosensor after thorough extraction and purification agreed well with that detected with the dcELISA. Protein A showed to be simple and reproducible for functionalization of the antibodies on the Au surface and, thus, has common application values in microcantilever immunosensor development. The results suggest that microcantilever immunosensors be suitable for detection of small molecules, and the assay sensitivity is mainly related to the quality and activities of the antibodies.
Biosensors based on Si3N4 asymmetric Mach-Zehnder interferometers
NASA Astrophysics Data System (ADS)
Chalyan, Tatevik; Pasquardini, Laura; Falke, Floris; Zanetti, Manuela; Guider, Romain; Gandolfi, Davide; Schreuder, Eric; Pederzolli, Cecilia; Heideman, René G.; Pavesi, Lorenzo
2016-04-01
In this work, we present a study on photonic biosensors based on Si3N4 asymmetric Mach-Zehnder Interferometers (aMZI) for Aflatoxin M1 (AFM1) detection. AFM1 is an hepatotoxic and a carcinogenic toxin present in milk. The biosensor is based on an array of four Si3N4 aMZI that are optimized for 850nm wavelength. We measure the bulk Sensitivity (S) and the Limit of Detection (LOD) of our devices. In the array, three devices are exposed and have very similar sensitivities. The fourth aMZI, which is covered by SiO2, is used as an internal reference for laser (a VCSEL) and temperature fluctuations. We measured a phase sensitivity of 14300+/-400 rad/RIU. To characterize the LOD of the sensors, we measure the uncertainty of the experimental readout system. From the measurements on three aMZI, we observe the same value of LOD, which is ≍ 4.5×10-7 RIU. After the sensor characterization on homogeneous sensing, we test the surface sensing performances by flowing specific Aflatoxin M1 and non-specific Ochratoxin in 50 mM MES pH 6.6 buffer on the top of the sensors functionalized with Antigen-Recognising Fragments (Fab'). The difference between specific and non-specific signals shows the specificity of our sensors. A moderate regeneration of the sensors is obtained by using glycine solution.
Bianchi, F; Careri, M; Maffini, M; Mangia, A; Mucchino, C
2003-01-01
A sensitive method for the simultaneous determination of (7)Li, (27)Al and (56)Fe by cold plasma ICP-MS was developed and validated. Experimental design was used to investigate the effects of torch position, torch power, lens 2 voltage, and coolant flow. Regression models and desirability functions were applied to find the experimental conditions providing the highest global sensitivity in a multi-elemental analysis. Validation was performed in terms of limits of detection (LOD), limits of quantitation (LOQ), linearity and precision. LODs were 1.4 and 159 ng L(-1) for (7)Li and (56)Fe, respectively; the highest LOD found being that for (27)Al (425 ng L(-1)). Linear ranges of 5 orders of magnitude for Li and 3 orders for Fe were statistically verified for each compound. Precision was evaluated by testing two concentration levels, and good results in terms of both intra-day repeatability and intermediate precision were obtained. RSD values lower than 4.8% at the lowest concentration level were calculated for intra-day repeatability. Commercially available soft drinks and alcoholic beverages contained in different packaging materials (TetraPack, polyethylene terephthalate (PET), commercial cans and glass) were analysed, and all the analytes were detected and quantitated. Copyright 2002 John Wiley & Sons, Ltd.
Caruso, Rosario; Scordino, Monica; Traulo, Pasqualino; Gagliano, Giacomo
2012-01-01
A capillary GC-flame ionization detection (FID) method to determine volatile compounds (ethyl acetate, 1,1-diethoxyethane, methyl alcohol, 1-propanol, 2-methyl-1-propanol, 2-methyl-1-butanol, 3-methyl-1-butanol, 1-butanol, and 2-butanol) in wine was investigated in terms of calculation of detection limits and calibration method. The main objectives were: (1) calculation of regression coefficient parameters by ordinary least-squares (OLS) and bivariate least-squares (BLS) regression models, taking into account errors in both axes; (2) estimation of linear dynamic range (LDR) according to International Conference on Harmonization recommendations; (3) performance evaluation of a method by using three different internal standards (ISs) such as acetonitrile, acetone, and 1-pentanol; (4) evaluation of LODs according to the U.S. Environmental Protection Agency (EPA) 3sigma approach and the Hubaux-Vos (H-V) method; (5) application of H-V theory to a gas chromatographic analytical method and to a food matrix; and (6) accuracy assessment of the method relative to methyl alcohol content through a Unione Italiana Vini (UIV) interlaboratory proficiency test. Calibration curves calculated via BLS and OLS show similar slopes, while intercepts are closer to zero in the first case, independent of the chosen IS. The studied ISs show a substantially equivalent behavior, even though the IS closer to the analyte retention time seems to be more appropriate in terms of LDR and LOD. Results indicate an underestimation of LODs using the EPA 3sigma approach instead of the more realistic H-V method, both with OLS and BLS regression models. Methanol contents compared with UIV average values indicate recovery between 90 and 110%.
Riedel, Timothy E; Zimmer-Faust, Amity G; Thulsiraj, Vanessa; Madi, Tania; Hanley, Kaitlyn T; Ebentier, Darcy L; Byappanahalli, Muruleedhara; Layton, Blythe; Raith, Meredith; Boehm, Alexandria B; Griffith, John F; Holden, Patricia A; Shanks, Orin C; Weisberg, Stephen B; Jay, Jennifer A
2014-04-01
Some molecular methods for tracking fecal pollution in environmental waters have both PCR and quantitative PCR (qPCR) assays available for use. To assist managers in deciding whether to implement newer qPCR techniques in routine monitoring programs, we compared detection limits (LODs) and costs of PCR and qPCR assays with identical targets that are relevant to beach water quality assessment. For human-associated assays targeting Bacteroidales HF183 genetic marker, qPCR LODs were 70 times lower and there was no effect of target matrix (artificial freshwater, environmental creek water, and environmental marine water) on PCR or qPCR LODs. The PCR startup and annual costs were the lowest, while the per reaction cost was 62% lower than the Taqman based qPCR and 180% higher than the SYBR based qPCR. For gull-associated assays, there was no significant difference between PCR and qPCR LODs, target matrix did not effect PCR or qPCR LODs, and PCR startup, annual, and per reaction costs were lower. Upgrading to qPCR involves greater startup and annual costs, but this increase may be justified in the case of the human-associated assays with lower detection limits and reduced cost per sample. Copyright © 2014 Elsevier Ltd. All rights reserved.
Riedel, Timothy E.; Zimmer-Faust, Amity G.; Thulsiraj, Vanessa; Madi, Tania; Hanley, Kaitlyn T.; Ebentier, Darcy L.; Byappanahalli, Muruleedhara N.; Layton, Blythe; Raith, Meredith; Boehm, Alexandria B.; Griffith, John F.; Holden, Patricia A.; Shanks, Orin C.; Weisberg, Stephen B.; Jay, Jennifer A.
2014-01-01
Some molecular methods for tracking fecal pollution in environmental waters have both PCR and quantitative PCR (qPCR) assays available for use. To assist managers in deciding whether to implement newer qPCR techniques in routine monitoring programs, we compared detection limits (LODs) and costs of PCR and qPCR assays with identical targets that are relevant to beach water quality assessment. For human-associated assays targeting Bacteroidales HF183 genetic marker, qPCR LODs were 70 times lower and there was no effect of target matrix (artificial freshwater, environmental creek water, and environmental marine water) on PCR or qPCR LODs. The PCR startup and annual costs were the lowest, while the per reaction cost was 62% lower than the Taqman based qPCR and 180% higher than the SYBR based qPCR. For gull-associated assays, there was no significant difference between PCR and qPCR LODs, target matrix did not effect PCR or qPCR LODs, and PCR startup, annual, and per reaction costs were lower. Upgrading to qPCR involves greater startup and annual costs, but this increase may be justified in the case of the human-associated assays with lower detection limits and reduced cost per sample.
Temporal trends and identification of the sources of volatile organic compounds in coastal seawater.
Bravo-Linares, Claudio M; Mudge, Stephen M
2009-03-01
Volatile Organic Compounds (VOCs) in the marine environment are produced by biogenic sources (marine macroalgae, phytoplankton, sediments, etc.) as well from anthropogenic sources. The temporal variation of such VOCs was studied together with their relationship to biological, meteorological and physico-chemical factors. Sixty four different VOCs were quantified including halogenated (
Conclusion of LOD-score analysis for family data generated under two-locus models.
Dizier, M. H.; Babron, M. C.; Clerget-Darpoux, F.
1996-01-01
The power to detect linkage by the LOD-score method is investigated here for diseases that depend on the effects of two genes. The classical strategy is, first, to detect a major-gene (MG) effect by segregation analysis and, second, to seek for linkage with genetic markers by the LOD-score method using the MG parameters. We already showed that segregation analysis can lead to evidence for a MG effect for many two-locus models, with the estimates of the MG parameters being very different from those of the two genes involved in the disease. We show here that use of these MG parameter estimates in the LOD-score analysis may lead to a failure to detect linkage for some two-locus models. For these models, use of the sib-pair method gives a non-negligible increase of power to detect linkage. The linkage-homogeneity test among subsamples differing for the familial disease distribution provides evidence of parameter misspecification, when the MG parameters are used. Moreover, for most of the models, use of the MG parameters in LOD-score analysis leads to a large bias in estimation of the recombination fraction and sometimes also to a rejection of linkage for the true recombination fraction. A final important point is that a strong evidence of an MG effect, obtained by segregation analysis, does not necessarily imply that linkage will be detected for at least one of the two genes, even with the true parameters and with a close informative marker. PMID:8651311
Wade, Mary Margaret; Biggs, Tracey D; Insalaco, Joseph M; Neuendorff, Lisa K; Bevilacqua, Vicky L H; Schenning, Amanda M; Reilly, Lisa M; Shah, Saumil S; Conley, Edward K; Emanuel, Peter A; Zulich, Alan W
2011-01-01
Development of a rapid field test is needed capable of determining if field supplies of water are safe to drink by the warfighter during a military operation. The present study sought to assess the effectiveness of handheld assays (HHAs) in detecting ricin and Staphylococcal Enterotoxin B (SEB) in water. Performance of HHAs was evaluated in formulated tap water with and without chlorine, reverse osmosis water (RO) with chlorine, and RO with bromine. Each matrix was prepared, spiked with ricin or SEB at multiple concentrations, and then loaded onto HHAs. HHAs were allowed to develop and then read visually. Limits of detection (LOD) were determined for all HHAs in each water type. Both ricin and SEB were detected by HHAs in formulated tap water at or below the suggested health effect levels of 455 ng/mL and 4.55 ng/mL, respectively. However, in brominated or chlorinated waters, LODs for SEB increased to approximately 2,500 ng/mL. LODs for ricin increased in chlorinated water, but still remained below the suggested health effect level. In brominated water, the LOD for ricin increased to approximately 2,500 ng/mL. In conclusion, the HHAs tested were less effective at detecting ricin and SEB in disinfected water, as currently configured.
Jiang, Tian-Jia; Guo, Zheng; Liu, Jin-Huai; Huang, Xing-Jiu
2015-08-18
An analytical technique based on electroadsorption and transmission X-ray fluorescence (XRF) for the quantitative determination of arsenic in aqueous solution with ppb-level limits of detection (LOD) is proposed. The approach uses electroadsorption to enhance the sensitivity and LOD of the arsenic XRF response. Amine-functionalized carbonaceous microspheres (NH2-CMSs) are found to be the ideal materials for both the quantitative adsorption of arsenic and XRF analysis due to the basic amine sites on the surface and their noninterference in the XRF spectrum. In electroadsorptive X-ray fluorescence (EA-XRF), arsenic is preconcentrated by a conventional three-electrode system with a positive electricity field around the adsorbents. Then, the quantification of arsenic on the adsorbents is achieved using XRF. The electroadsorption preconcentration can realize the fast transfer of arsenic from the solution to the adsorbents and improve the LOD of conventional XRF compared with directly determining arsenic solution by XRF alone. The sensitivity of 0.09 cnt ppb(-1) is obtained without the interferences from coexisted metal ions in the determination of arsenic, and the LOD is found to be 7 ppb, which is lower than the arsenic guideline value of 10 ppb given by the World Health Organization (WHO). These results demonstrated that XRF coupled with electroadsorption was able to determine trace arsenic in real water sample.
Saqib, Muhammad; Qi, Liming; Hui, Pan; Nsabimana, Anaclet; Halawa, Mohamed Ibrahim; Zhang, Wei; Xu, Guobao
2018-01-15
N-hydroxyphthalimide (NHPI), a well known reagent in organic synthesis and biochemical applications, has been developed as a stable and efficient chemiluminescence coreactant for the first time. It reacts with luminol much faster than N-hydroxysuccinimide, eliminating the need of a prereaction coil used in N-hydroxysuccinimide system. Without using prereaction coil, the chemiluminescence peak intensities of luminol-NHPI system are about 102 and 26 times greater than that of luminol-N-hydroxysuccinimide system and classical luminol-hydrogen peroxide system, respectively. The luminol-NHPI system achieves the highly sensitive detection of luminol (LOD = 70pM) and NHPI (LOD = 910nM). Based on their excellent quenching efficiencies, superoxide dismutase and uric acid are sensitively detected with LODs of 3ng/mL and 10pM, respectively. Co 2+ is also detected a LOD of 30pM by its remarkable enhancing effect. Noteworthily, our method is at least 4 orders of magnitude more sensitive than previously reported uric acid detection methods, and can detect uric acid in human urine and Co 2+ in tap and lake water real samples with excellent recoveries in the range of 96.35-102.70%. This luminol-NHPI system can be an important candidate for biochemical, clinical and environmental analysis. Copyright © 2017 Elsevier B.V. All rights reserved.
Chen, Rui; Huang, Xiaolin; Xu, Hengyi; Xiong, Yonghua; Li, Yanbin
2015-12-30
Plasmonic enzyme-linked immunosorbent assay (pELISA) based on catalase (CAT)-mediated gold nanoparticle growth exhibits ultrahigh sensitivity for detecting disease-related biomarkers using sandwich formats. However, the limit of detection (LOD) of this strategy for Listeria monocytogenes is only around 10(3) CFU/mL, which considerably exceeds the amount of L. monocytogenes commonly present in food products (<100 CFU/g). Herein, we report an improved pELISA method for detection of L. monocytogenes at ultralow concentrations with the sandwich formats using silica nanoparticles carrying poly(acrylic acid) brushes as a "CAT container" to increase enzyme loading for enhancing the detection signal. Under optimal conditions, the proposed pELISA exhibits good specificity and excellent sensitivity for L. monocytogenes with a LOD of 8 × 10(1) CFU/mL in 0.01 M phosphate-buffered saline, via a reaction that can be discriminated by the naked eye. The LOD obtained by this method was 2 and 5 orders of magnitude lower than that of conventional CAT-based pELISA and horseradish peroxidase (HRP)-based conventional ELISA, respectively. Coupled with large-volume immunomagnetic separation, the LOD for L. monocytogenes-spiked lettuce samples reached 8 × 10(1) CFU/g. The improved pELISA also exhibited a great potential in detecting a single cell of L. monocytogenes in 100 μL of solution.
Xing, Chao; Elston, Robert C
2006-07-01
The multipoint lod score and mod score methods have been advocated for their superior power in detecting linkage. However, little has been done to determine the distribution of multipoint lod scores or to examine the properties of mod scores. In this paper we study the distribution of multipoint lod scores both analytically and by simulation. We also study by simulation the distribution of maximum multipoint lod scores when maximized over different penetrance models. The multipoint lod score is approximately normally distributed with mean and variance that depend on marker informativity, marker density, specified genetic model, number of pedigrees, pedigree structure, and pattern of affection status. When the multipoint lod scores are maximized over a set of assumed penetrances models, an excess of false positive indications of linkage appear under dominant analysis models with low penetrances and under recessive analysis models with high penetrances. Therefore, caution should be taken in interpreting results when employing multipoint lod score and mod score approaches, in particular when inferring the level of linkage significance and the mode of inheritance of a trait.
Wavelet analysis of interannual LOD, AAM, and ENSO: 1997-98 El Niño and 1998-99 La Niña signals
NASA Astrophysics Data System (ADS)
Zhou, Y. H.; Zheng, D. W.; Liao, X. H.
2001-05-01
On the basis of the data series of the length of day (LOD), the atmospheric angular momentum (AAM) and the Southern Oscillation Index (SOI) for January 1970-June 1999, the relationship among Interannual LOD, AAM, and the EL Niño/Southern Oscillation (ENSO) is analyzed by the wavelet transform method. The results suggest that they have similar time-varying spectral structures. The signals of 1997-98 El Niño and 1998-99 La Niña events can be detected from the LOD or AAM data.
Khairnar, Krishna; Martin, Donald; Lau, Rachel; Ralevski, Filip; Pillai, Dylan R
2009-12-09
Accurate laboratory diagnosis of malaria species in returning travelers is paramount in the treatment of this potentially fatal infectious disease. A total of 466 blood specimens from returning travelers to Africa, Asia, and South/Central America with suspected malaria infection were collected between 2007 and 2009 at the reference public health laboratory. These specimens were assessed by reference microscopy, multipex real-time quantitative polymerase chain reaction (QPCR), and two rapid diagnostic immuno-chromatographic tests (ICT) in a blinded manner. Key clinical laboratory parameters such as limit of detection (LOD) analysis on clinical specimens by parasite stage, inter-reader variability of ICTs, staffing implications, quality assurance and cost analysis were evaluated. QPCR is the most analytically sensitive method (sensitivity 99.41%), followed by CARESTART (sensitivity 88.24%), and BINAXNOW (sensitivity 86.47%) for the diagnosis of malaria in returning travelers when compared to reference microscopy. However, microscopy was unable to specifically identify Plasmodia spp. in 18 out of 170 positive samples by QPCR. Moreover, the 17 samples that were negative by microscopy and positive by QPCR were also positive by ICTs. Quality assurance was achieved for QPCR by exchanging a blinded proficiency panel with another reference laboratory. The Kappa value of inter-reader variability among three readers for BINAXNOW and CARESTART was calculated to be 0.872 and 0.898 respectively. Serial dilution studies demonstrated that the QPCR cycle threshold correlates linearly with parasitemia (R(2) = 0.9746) in a clinically relevant dynamic range and retains a LOD of 11 rDNA copies/microl for P. falciparum, which was several log lower than reference microscopy and ICTs. LOD for QPCR is affected not only by parasitemia but the parasite stage distribution of each clinical specimen. QPCR was approximately 6-fold more costly than reference microscopy. These data suggest that multiplex QPCR although more costly confers a significant diagnostic advantage in terms of LOD compared to reference microscopy and ICTs for all four species. Quality assurance of QPCR is essential to the maintenance of proficiency in the clinical laboratory. ICTs showed good concordance between readers however lacked sensitivity for non-falciparum species due to antigenic differences and low parasitemia. Multiplex QPCR but not ICTs is an essential adjunct to microscopy in the reference laboratory detection of malaria species specifically due to the superior LOD. ICTs are better suited to the non-reference laboratory where lower specimen volumes challenge microscopy proficiency in the non-endemic setting.
An iPhone-based digital image colorimeter for detecting tetracycline in milk.
Masawat, Prinya; Harfield, Antony; Namwong, Anan
2015-10-01
An iPhone-based digital image colorimeter (DIC) was fabricated as a portable tool for monitoring tetracycline (TC) in bovine milk. An application named ColorConc was developed for the iPhone that utilizes an image matching algorithm to determine the TC concentration in a solution. The color values; red (R), green (G), blue (B), hue (H), saturation (S), brightness (V), and gray (Gr) were measured from each pictures of the TC standard solutions. TC solution extracted from milk samples using solid phase extraction (SPE) was captured and the concentration was predicted by comparing color values with those collected in a database. The amount of TC could be determined in the concentration range of 0.5-10 μg mL(-1). The proposed DIC-iPhone is able to provide a limit of detection (LOD) of 0.5 μg mL(-1) and limit of quantitation (LOQ) of 1.5 μg mL(-1). The enrichment factor was 70 and color of the extracted milk sample was a strong yellow solution after SPE. Therefore, the SPE-DIC-iPhone could be used for the assay of TC residues in milk at the concentration lower than LOD and LOQ of the proposed technique. Copyright © 2015 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harris, Candace; Profeta, Luisa; Akpovo, Codjo
The psuedo univariate limit of detection was calculated to compare to the multivariate interval. ompared with results from the psuedounivariate LOD, the multivariate LOD includes other factors (i.e. signal uncertainties) and the reveals the significance in creating models that not only use the analyte’s emission line but also its entire molecular spectra.
Feasibility study of a Raman spectroscopic route to drug detection
NASA Astrophysics Data System (ADS)
Wróbel, Maciej S.; Siddhanta, Soumik; Jedrzejewska-Szczerska, Małgorzata; Smulko, Janusz; Barman, Ishan
2017-02-01
We present an surface-enhanced Raman spectroscopy (SERS) approach for detection of drugs of abuse in whole human blood. We utilize a near infrared laser with 830 nm excitation wavelength in order to reduce the influence of fluorescence on the spectra of blood. However, regular plasmon resonance peak of plasmonic nanoparticles, such as silver or gold fall in a much lower wavelength regime about 400 nm. Therefore, we have shifted the plasmon resonance of nanoparticles to match that of an excitation laser wavelength, by fabrication of the silver-core gold-shell nanoparticles. By combining the laser and plasmon resonance shift towards longer wavelengths we have achieved a great reduction in background fluorescence of blood. Great enhancement of Raman signal coming solely from drugs was achieved without any prominent lines coming from the erythrocytes. We have applied chemometric processing methods, such as Principal Component Analysis (PCA), to detect the elusive differences in the Raman bands which are specific for the investigated drugs. We have achieved good classification for the samples containing particular drugs (e.g., butalbital, α-hydroxyalprazolam). Furthermore, a quantitative analysis was carried out to assess the limit of detection (LOD) using Partial Least Squares (PLS) regression method. In conclusion, our LOD values obtained for each class of drugs was competitive with the gold standard GC/MS method.
Vochyánová, Blanka; Opekar, František; Tůma, Petr
2014-06-01
A method has been developed for the simultaneous determination of taurine and caffeine using a laboratory-made instrument enabling separation analysis in a short 10.5 cm capillary. The substances are detected using a contactless conductometry/ultraviolet (UV) photometry detector that enables recording both signals at one place in the capillary. The separation of caffeine and taurine was performed using the MEKC technique in a BGE with the composition 40 mM CHES, 15 mM NaOH, and 50 mM SDS, pH 9.36. Under these conditions, the migration time of caffeine is 43 s and of taurine 60 s; LOD for caffeine is 4 mg/L using photometric detection and LOD for taurine is 24 mg/L using contactless conductometric detection. The standard addition method was used for determination in Red Bull energy drink of caffeine 317 mg/L and taurine 3860 mg/L; the contents in Kamikaze drink were 468 mg/L caffeine and 4110 mg/L taurine. The determined values are in good agreement with the declared contents of these substances. RSD does not exceed 3%. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Atmospheric and Oceanic Excitations to LOD Change on Quasi-biennial Time Scales
NASA Astrophysics Data System (ADS)
Ma, Li-Hua; Liao, De-Chun; Han, Yan-Ben
2006-12-01
We use wavelet transform to study the time series of the Earth's rotation rate (length-of-day, LOD), the axial components of atmospheric angular momentum (AAM) and oceanic angular momentum (OAM) in the period 1962--2005, and discuss the quasi-biennial oscillations (QBO) of LOD change. The results show that the QBO of LOD change varies remarkably in amplitude and phase. It was weak before 1978, then became much stronger and reached maximum values during the strong El Nino events in around 1983 and 1997. Results from analyzing the axial AAM indicate that the QBO signals in axial AAM are extremely consistent with the QBOs of LOD change. During 1963--2003, the QBO variance in the axial AAM can explain about 99.0% of that of the LOD, in other words, all QBO signals of LOD change are almost excited by the axial AAM, while the weak QBO signals of the axial OAM are quite different from those of the LOD and the axial AAM in both time-dependent characteristics and magnitudes. The combined effects of the axial AAM and OAM can explain about 99.1% of the variance of QBO in LOD change during this period.
Influence analysis in quantitative trait loci detection.
Dou, Xiaoling; Kuriki, Satoshi; Maeno, Akiteru; Takada, Toyoyuki; Shiroishi, Toshihiko
2014-07-01
This paper presents systematic methods for the detection of influential individuals that affect the log odds (LOD) score curve. We derive general formulas of influence functions for profile likelihoods and introduce them into two standard quantitative trait locus detection methods-the interval mapping method and single marker analysis. Besides influence analysis on specific LOD scores, we also develop influence analysis methods on the shape of the LOD score curves. A simulation-based method is proposed to assess the significance of the influence of the individuals. These methods are shown useful in the influence analysis of a real dataset of an experimental population from an F2 mouse cross. By receiver operating characteristic analysis, we confirm that the proposed methods show better performance than existing diagnostics. © 2014 The Author. Biometrical Journal published by WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Wade, Mary Margaret; Biggs, Tracey D.; Insalaco, Joseph M.; Neuendorff, Lisa K.; Bevilacqua, Vicky L. H.; Schenning, Amanda M.; Reilly, Lisa M.; Shah, Saumil S.; Conley, Edward K.; Emanuel, Peter A.; Zulich, Alan W.
2011-01-01
Development of a rapid field test is needed capable of determining if field supplies of water are safe to drink by the warfighter during a military operation. The present study sought to assess the effectiveness of handheld assays (HHAs) in detecting ricin and Staphylococcal Enterotoxin B (SEB) in water. Performance of HHAs was evaluated in formulated tap water with and without chlorine, reverse osmosis water (RO) with chlorine, and RO with bromine. Each matrix was prepared, spiked with ricin or SEB at multiple concentrations, and then loaded onto HHAs. HHAs were allowed to develop and then read visually. Limits of detection (LOD) were determined for all HHAs in each water type. Both ricin and SEB were detected by HHAs in formulated tap water at or below the suggested health effect levels of 455 ng/mL and 4.55 ng/mL, respectively. However, in brominated or chlorinated waters, LODs for SEB increased to approximately 2,500 ng/mL. LODs for ricin increased in chlorinated water, but still remained below the suggested health effect level. In brominated water, the LOD for ricin increased to approximately 2,500 ng/mL. In conclusion, the HHAs tested were less effective at detecting ricin and SEB in disinfected water, as currently configured. PMID:21792355
Ordered-subsets linkage analysis detects novel Alzheimer disease loci on chromosomes 2q34 and 15q22.
Scott, William K; Hauser, Elizabeth R; Schmechel, Donald E; Welsh-Bohmer, Kathleen A; Small, Gary W; Roses, Allen D; Saunders, Ann M; Gilbert, John R; Vance, Jeffery M; Haines, Jonathan L; Pericak-Vance, Margaret A
2003-11-01
Alzheimer disease (AD) is a complex disorder characterized by a wide range, within and between families, of ages at onset of symptoms. Consideration of age at onset as a covariate in genetic-linkage studies may reduce genetic heterogeneity and increase statistical power. Ordered-subsets analysis includes continuous covariates in linkage analysis by rank ordering families by a covariate and summing LOD scores to find a subset giving a significantly increased LOD score relative to the overall sample. We have analyzed data from 336 markers in 437 multiplex (>/=2 sampled individuals with AD) families included in a recent genomic screen for AD loci. To identify genetic heterogeneity by age at onset, families were ordered by increasing and decreasing mean and minimum ages at onset. Chromosomewide significance of increases in the LOD score in subsets relative to the overall sample was assessed by permutation. A statistically significant increase in the nonparametric multipoint LOD score was observed on chromosome 2q34, with a peak LOD score of 3.2 at D2S2944 (P=.008) in 31 families with a minimum age at onset between 50 and 60 years. The LOD score in the chromosome 9p region previously linked to AD increased to 4.6 at D9S741 (P=.01) in 334 families with minimum age at onset between 60 and 75 years. LOD scores were also significantly increased on chromosome 15q22: a peak LOD score of 2.8 (P=.0004) was detected at D15S1507 (60 cM) in 38 families with minimum age at onset >/=79 years, and a peak LOD score of 3.1 (P=.0006) was obtained at D15S153 (62 cM) in 43 families with mean age at onset >80 years. Thirty-one families were contained in both 15q22 subsets, indicating that these results are likely detecting the same locus. There is little overlap in these subsets, underscoring the utility of age at onset as a marker of genetic heterogeneity. These results indicate that linkage to chromosome 9p is strongest in late-onset AD and that regions on chromosome 2q34 and 15q22 are linked to early-onset AD and very-late-onset AD, respectively.
Genome-wide linkage scan for submaximal exercise heart rate in the HERITAGE family study.
Spielmann, Nadine; Leon, Arthur S; Rao, D C; Rice, Treva; Skinner, James S; Rankinen, Tuomo; Bouchard, Claude
2007-12-01
The purpose of this study was to identify regions of the human genome linked to submaximal exercise heart rates in the sedentary state and in response to a standardized 20-wk endurance training program in blacks and whites of the HERITAGE Family Study. A total of 701 polymorphic markers covering the 22 autosomes were used in the genome-wide linkage scan, with 328 sibling pairs from 99 white nuclear families and 102 pairs from 115 black family units. Steady-state heart rates were measured at the relative intensity of 60% maximal oxygen uptake (HR60) and at the absolute intensity of 50 W (HR50). Baseline phenotypes were adjusted for age, sex, and baseline body mass index (BMI) and training responses (posttraining minus baseline, Delta) were adjusted for age, sex, baseline BMI, and baseline value of the phenotype. Two analytic strategies were used, a multipoint variance components and a regression-based multipoint linkage analysis. In whites, promising linkages (LOD > 1.75) were identified on 18q21-q22 for baseline HR50 (LOD = 2.64; P = 0.0002) and DeltaHR60 (LOD = 2.10; P = 0.0009) and on chromosome 2q33.3 for DeltaHR50 (LOD = 2.13; P = 0.0009). In blacks, evidence of promising linkage for baseline HR50 was detected with several markers within the chromosomal region 10q24-q25.3 (peak LOD = 2.43, P = 0.0004 with D10S597). The most promising regions for fine mapping in the HERITAGE Family Study were found on 2q33 for HR50 training response in whites, on 10q25-26 for baseline HR60 in blacks, and on 18q21-22 for both baseline HR50 and DeltaHR60 in whites.
NASA Astrophysics Data System (ADS)
Medvedev, Nickolay S.; Shaverina, Anastasiya V.; Tsygankova, Alphiya R.; Saprykin, Anatoly I.
2018-04-01
The paper presents а comparison of analytical performances of inductively coupled plasma mass spectrometry (ICP-MS) and inductively coupled plasma atomic emission spectrometry (ICP-AES) for trace analysis of high purity bismuth and bismuth oxide. Matrix effects in the ICP-MS and ICP-AES methods were studied as a function of Bi concentration, ICP power and nebulizer flow rate. For ICP-MS the strong dependence of the matrix effects versus the atomic mass of analytes was observed. For ICP-AES the minimal matrix effects were achieved for spectral lines of analytes with low excitation potentials. The optimum degree of sample dilution providing minimum values of the limits of detection (LODs) was chosen. Both methods let us to reach LODs from n·10-7 to n·10-4 wt% for more than 50 trace elements. For most elements the LODs of ICP-MS were lower in comparison to ICP-AES. Validation of accuracy of the developed techniques was performed by "added-found" experiments and by comparison of the results of ICP-MS and ICP-AES analysis of high-purity bismuth oxide.
Hühn, M; Piepho, H P
2003-03-01
Tests for linkage are usually performed using the lod score method. A critical question in linkage analyses is the choice of sample size. The appropriate sample size depends on the desired type-I error and power of the test. This paper investigates the exact type-I error and power of the lod score method in a segregating F(2) population with co-dominant markers and a qualitative monogenic dominant-recessive trait. For illustration, a disease-resistance trait is considered, where the susceptible allele is recessive. A procedure is suggested for finding the appropriate sample size. It is shown that recessive plants have about twice the information content of dominant plants, so the former should be preferred for linkage detection. In some cases the exact alpha-values for a given nominal alpha may be rather small due to the discrete nature of the sampling distribution in small samples. We show that a gain in power is possible by using exact methods.
Ghamouss, Fouad; Ledru, Sophie; Ruillé, Nadine; Lantier, Françoise; Boujtita, Mohammed
2006-06-16
A screen-printed carbon electrode modified with both HRP and LOD (SPCE-HRP/LOD) has been developed for the determination of L-lactate concentration in real samples. The resulting SPCE-HRP/LOD was prepared in a one-step procedure, and was then optimised as an amperometric biosensor operating at [0, -100]mV versus Ag/AgCl for L-lactate determination in flow injection mode. A significant improvement in the reproducibility (coefficient variation of about 10%) of the preparation of the biosensors was obtained when graphite powder was modified with LOD in the presence of HRP previously oxidised by periodate ion (IO4-). Optimisation studies were performed by examining the effects of LOD loading, periodation step and rate of the binder on analytical performances of SPCE-HRP/LOD. The sensitivity of the optimised SPCE-HRP/LOD to L-lactate was 0.84 nAL micromol(-1) in a detection range between 10 and 180 microMol. The possibility of using the developed biosensor to determine L-lactate concentrations in various dairy products was also evaluated.
Linyu, Wang; Manwen, Yao; Chengzhi, Fang; Xi, Yao
2017-09-01
A strategy has been applied to chloramphenicol (CAP) detection with chemiluminescence immunoassays (CLIA) based on cheap functionalized Fe 3 O 4 @SiO 2 magnetic nanoparticles (Fe-MNPs). The strategy that bovine serum albumin (BSA) was immobilized on cheap functionalized Fe-MNPs and that the CAP molecules were then immobilized on BSA, avoided the long process of dialysis for preparation of the BSA-CAP conjugates. The samples were detected for both methods that utilized two different kinds of functionalized Fe-MNPs (amine-functionalized Fe 3 O 4 @SiO 2 and carboxylic acid-functionalized Fe 3 O 4 @SiO 2 ). The sensitivities and limits of detection (LODs) of the two methods were obtained and compared based on inhibition curves. The 50% inhibition concentrations (IC 50 ) values of the two methods were about 0.024 ng ml -1 and 0.046 ng ml -1 respectively and LODs were approximately 0.0002 ng ml -1 and 0.001 ng ml -1 respectively. These methods were much more sensitive than that of any traditional enzyme-linked immunosorbent assay (ELISA) previously reported. Therefore, such chemiluminescence methods could be easily adapted for small molecule detection in a variety of foods using Fe-MNPs. Copyright © 2017 John Wiley & Sons, Ltd.
Ramezani, Mohammad; Abnous, Khalil; Taghdisi, Seyed Mohammad
2017-01-01
Detection and quantitation of antibiotic residues in blood serum and foodstuffs are in great demand. We have developed aptasensors for detection of streptomycin using electrochemical and optical methods. In the first method, an electrochemical aptasensor was developed for sensitive and selective detection of streptomycin, based on combination of exonuclease I (Exo I), complementary strand of aptamer (CS), arch shaped structure of aptamer (Apt)-CS conjugate, and gold electrode. The designed electrochemical aptasensor exhibited high selectivity toward streptomycin with a limit of detection (LOD) as low as 11.4 nM. Moreover, the developed electrochemical aptasensor was successfully used to detect streptomycin in milk and serum with LODs of 14.1 and 15.3 nM, respectively. In the second method, fluorescence quenching and colorimetric aptasensors were designed for detection of streptomycin based on aqueous gold nanoparticles (AuNPs) and double-stranded DNA (dsDNA). In the absence of streptomycin, aptamer/FAM-labeled complementary strand dsDNA is stable, resulting in the aggregation of AuNPs by salt bridge and an obvious color change from red to blue and strong emission of fluorescence. The colorimetric and fluorescence quenching aptasensors showed excellent selectivity toward streptomycin with limit of detections as low as 73.1 and 47.6 nM, respectively. The presented aptasensors were successfully used to detect streptomycin in milk and serum. For serum, LODs were determined to be 58.2 and 102.4 nM for fluorescence quenching and colorimetric aptasensors, respectively. For milk, LODs were calculated to be 56.2 and 108.7 nM for fluorescence quenching and colorimetric aptasensors, respectively.
D-dimer as marker for microcirculatory failure: correlation with LOD and APACHE II scores.
Angstwurm, Matthias W A; Reininger, Armin J; Spannagl, Michael
2004-01-01
The relevance of plasma d-dimer levels as marker for morbidity and organ dysfunction in severely ill patients is largely unknown. In a prospective study we determined d-dimer plasma levels of 800 unselected patients at admission to our intensive care unit. In 91% of the patients' samples d-dimer levels were elevated, in some patients up to several hundredfold as compared to normal values. The highest mean d-dimer values were present in the patient group with thromboembolic diseases, and particularly in non-survivors of pulmonary embolism. In patients with circulatory impairment (r=0.794) and in patients with infections (r=0.487) a statistically significant correlation was present between d-dimer levels and the APACHE II score (P<0.001). The logistic organ dysfunction score (LOD, P<0.001) correlated with d-dimer levels only in patients with circulatory impairment (r=0.474). On the contrary, patients without circulatory impairment demonstrated no correlation of d-dimer levels to the APACHE II or LOD score. Taking all patients together, no correlations of d-dimer levels with single organ failure or with indicators of infection could be detected. In conclusion, d-dimer plasma levels strongly correlated with the severity of the disease and organ dysfunction in patients with circulatory impairment or infections suggesting that elevated d-dimer levels may reflect the extent of microcirculatory failure. Thus, a therapeutic strategy to improve the microcirculation in such patients may be monitored using d-dimer plasma levels.
High-throughput quantitative analysis by desorption electrospray ionization mass spectrometry.
Manicke, Nicholas E; Kistler, Thomas; Ifa, Demian R; Cooks, R Graham; Ouyang, Zheng
2009-02-01
A newly developed high-throughput desorption electrospray ionization (DESI) source was characterized in terms of its performance in quantitative analysis. A 96-sample array, containing pharmaceuticals in various matrices, was analyzed in a single run with a total analysis time of 3 min. These solution-phase samples were examined from a hydrophobic PTFE ink printed on glass. The quantitative accuracy, precision, and limit of detection (LOD) were characterized. Chemical background-free samples of propranolol (PRN) with PRN-d(7) as internal standard (IS) and carbamazepine (CBZ) with CBZ-d(10) as IS were examined. So were two other sample sets consisting of PRN/PRN-d(7) at varying concentration in a biological milieu of 10% urine or porcine brain total lipid extract, total lipid concentration 250 ng/microL. The background-free samples, examined in a total analysis time of 1.5 s/sample, showed good quantitative accuracy and precision, with a relative error (RE) and relative standard deviation (RSD) generally less than 3% and 5%, respectively. The samples in urine and the lipid extract required a longer analysis time (2.5 s/sample) and showed RSD values of around 10% for the samples in urine and 4% for the lipid extract samples and RE values of less than 3% for both sets. The LOD for PRN and CBZ when analyzed without chemical background was 10 and 30 fmol, respectively. The LOD of PRN increased to 400 fmol analyzed in 10% urine, and 200 fmol when analyzed in the brain lipid extract.
Degelmann, Petra; Egger, Sebastian; Jürling, Heinrich; Müller, Josef; Niessner, Reinhard; Knopp, Dietmar
2006-03-22
Immunoaffinity supports (IAS) were prepared using broad specific polyclonal anti-sulfonylurea (SU) antibodies immobilized in sol-gel glass. Two different kinds of supports were applied, crushed sol-gel monoliths and sol-gel-coated highly porous silica particles. Both were used for the quantitative enrichment of SUs in natural water and food samples followed by high-performance liquid chromatography-ultraviolet/diode array detection (HPLC-UV/DAD) and tandem mass spectrometry (LC-MS/MS), respectively. Loading, washing, and elution conditions of IAS were optimized. The capacity of supports was determined for 30 SUs and compared with the cross-reactivity pattern of the direct competitive enzyme-linked immunosorbent assay. The capacities correlated well with the affinity to individual SU compounds. Even analytes to which the polyclonal antibodies showed only a lower cross-reactivity could be enriched to a certain degree, if a sufficient capacity of IAS was provided. The IAS could be reused at least 10 times without a loss of effectiveness. Recovery of 16 selected SUs extracted from spiked water and food samples was dependent on the affinity of both immobilized antibodies to single compounds and matrix interferences. In water, 13 SUs showed recoveries higher than 80% when immunoaffinity extraction was used in combination with LC-UV/DAD. On the basis of the enrichment of 200 mL of aqueous sample, corresponding limit of detection (LOD) values ranged between 20 and 100 ng/L. The recoveries of 10 SUs, which were extracted from 10 g of potato spiked at a 10 microg/kg level, were higher than 75%. For grain samples, recoveries were at the same order for at least five SU herbicides. The LOD of LC-MS/MS measurements was about 1 order of magnitude higher, i.e., gave LODs between 1.1 and 6.9 microg/kg of food sample, depending on the compound and extraction procedure. These LODs provide evidence that the main advantage of the prepared IAS is their high selectivity for group specific recognition of SUs as compared to other nonspecific solid phase extraction materials.
Successional stage of biological soil crusts: an accurate indicator of ecohydrological condition
Belnap, Jayne; Wilcox, Bradford P.; Van Scoyoc, Matthew V.; Phillips, Susan L.
2013-01-01
Biological soil crusts are a key component of many dryland ecosystems. Following disturbance, biological soil crusts will recover in stages. Recently, a simple classification of these stages has been developed, largely on the basis of external features of the crusts, which reflects their level of development (LOD). The classification system has six LOD classes, from low (1) to high (6). To determine whether the LOD of a crust is related to its ecohydrological function, we used rainfall simulation to evaluate differences in infiltration, runoff, and erosion among crusts in the various LODs, across a range of soil depths and with different wetting pre-treatments. We found large differences between the lowest and highest LODs, with runoff and erosion being greatest from the lowest LOD. Under dry antecedent conditions, about 50% of the water applied ran off the lowest LOD plots, whereas less than 10% ran off the plots of the two highest LODs. Similarly, sediment loss was 400 g m-2 from the lowest LOD and almost zero from the higher LODs. We scaled up the results from these simulations using the Rangeland Hydrology and Erosion Model. Modelling results indicate that erosion increases dramatically as slope length and gradient increase, especially beyond the threshold values of 10 m for slope length and 10% for slope gradient. Our findings confirm that the LOD classification is a quick, easy, nondestructive, and accurate index of hydrological condition and should be incorporated in field and modelling assessments of ecosystem health.
Graphene-metallic nanocomposites as modifiers in electrochemical glucose biosensor transducers
NASA Astrophysics Data System (ADS)
Altuntas, Derya Bal; Tepeli, Yudum; Anik, Ulku
2016-09-01
Graphene sheets and three different graphene-metallic nanocomposites including graphene-copper (graphene-Cu), graphene-nickel (graphene-Ni) and graphene-platinum (graphene-Pt) were prepared and characterized in the first place. Then the electrochemical performances of these nanocomposites were tested in glucose biosensor transducers, which were formed by combining these metallic nanocomposites with glucose oxidase enzyme and glassy carbon paste electrode (GCPE). This is the first work that includes the usage of these graphene-Me nanocomposites as a part of glucose biosensor transducer. Fabricated amperometric biosensors linear ranges were obtained as follow: For the plain graphene, the linear range was found in the concentration range between 50 μM and 800 μM with the RSD (n = 3 for 50 μM glucose) value of 12.86% and LOD value of 7.2 μM. For graphene-Pt modified glucose biosensor, the linear range was between 10 μM and 600 μM with the RSD (n = 3 for 50 μM glucose) value of 3.45% and LOD value of 3.06 μM. In the case of graphene-Ni modified glucose biosensor, the values were 25 μM to 600 μM with the RSD (n = 3 for 50 μM glucose) value of 8.76% and LOD value of 24.71 μM and for graphene-Cu modified glucose biosensor linear range was 25 μM to 400 μM with the RSD (n = 3 for 50 μM glucose) value of 3.93% and LOD value of 2.87 μM.
Tijunelyte, Inga; Betelu, Stéphanie; Moreau, Jonathan; Ignatiadis, Ioannis; Berho, Catherine; Lidgi-Guigui, Nathalie; Guénin, Erwann; David, Catalina; Vergnole, Sébastien; Rinnert, Emmanuel; Lamy de la Chapelle, Marc
2017-01-01
Here, we present a surface-enhanced Raman spectroscopy (SERS) nanosensor for environmental pollutants detection. This study was conducted on three polycyclic aromatic hydrocarbons (PAHs): benzo[a]pyrene (BaP), fluoranthene (FL), and naphthalene (NAP). SERS substrates were chemically functionalized using 4-dodecyl benzenediazonium-tetrafluoroborate and SERS analyses were conducted to detect the pollutants alone and in mixtures. Compounds were first measured in water-methanol (9:1 volume ratio) samples. Investigation on solutions containing concentrations ranging from 10−6 g L−1 to 10−3 g L−1 provided data to plot calibration curves and to determine the performance of the sensor. The calculated limit of detection (LOD) was 0.026 mg L−1 (10−7 mol L−1) for BaP, 0.064 mg L−1 (3.2 × 10−7 mol L−1) for FL, and 3.94 mg L−1 (3.1 × 10−5 mol L−1) for NAP, respectively. The correlation between the calculated LOD values and the octanol-water partition coefficient (Kow) of the investigated PAHs suggests that the developed nanosensor is particularly suitable for detecting highly non-polar PAH compounds. Measurements conducted on a mixture of the three analytes (i) demonstrated the ability of the developed technology to detect and identify the three analytes in the mixture; (ii) provided the exact quantitation of pollutants in a mixture. Moreover, we optimized the surface regeneration step for the nanosensor. PMID:28538680
Tijunelyte, Inga; Betelu, Stéphanie; Moreau, Jonathan; Ignatiadis, Ioannis; Berho, Catherine; Lidgi-Guigui, Nathalie; Guénin, Erwann; David, Catalina; Vergnole, Sébastien; Rinnert, Emmanuel; Lamy de la Chapelle, Marc
2017-05-24
Here, we present a surface-enhanced Raman spectroscopy (SERS) nanosensor for environmental pollutants detection. This study was conducted on three polycyclic aromatic hydrocarbons (PAHs): benzo[a]pyrene (BaP), fluoranthene (FL), and naphthalene (NAP). SERS substrates were chemically functionalized using 4-dodecyl benzenediazonium-tetrafluoroborate and SERS analyses were conducted to detect the pollutants alone and in mixtures. Compounds were first measured in water-methanol (9:1 volume ratio) samples. Investigation on solutions containing concentrations ranging from 10 -6 g L -1 to 10 -3 g L -1 provided data to plot calibration curves and to determine the performance of the sensor. The calculated limit of detection (LOD) was 0.026 mg L -1 (10 -7 mol L -1 ) for BaP, 0.064 mg L -1 (3.2 × 10 -7 mol L -1 ) for FL, and 3.94 mg L -1 (3.1 × 10 -5 mol L -1 ) for NAP, respectively. The correlation between the calculated LOD values and the octanol-water partition coefficient (K ow ) of the investigated PAHs suggests that the developed nanosensor is particularly suitable for detecting highly non-polar PAH compounds. Measurements conducted on a mixture of the three analytes (i) demonstrated the ability of the developed technology to detect and identify the three analytes in the mixture; (ii) provided the exact quantitation of pollutants in a mixture. Moreover, we optimized the surface regeneration step for the nanosensor.
Greda, Krzysztof; Swiderski, Krzysztof; Jamroz, Piotr; Pohl, Pawel
2016-09-06
A novel atmospheric pressure glow discharge generated in contact with a flowing liquid anode (FLA-APGD) was developed as the efficient excitation source for the optical emission spectrometry (OES) detection. Differences in the appearance and the electrical characteristic of the FLA-APGD and a conventional system operated with a flowing liquid cathode (FLC-APGD) were studied in detail and discussed. Under the optimal operating conditions for the FLA-APGD, the emission from the analytes (Ag, Cd, Hg, Pb, Tl, and Zn) was from 20 to 120 times higher as compared to the FLC-APGD. Limits of detections (LODs) established with a novel FLA-APGD system were on average 20 times better than those obtained for the FLC-APGD. A further improvement of the LODs was achieved by reducing the background shift interferences and, as a result, the LODs for Ag, Cd, Hg, Pb, Tl, and Zn were 0.004, 0.040, 0.70, 1.7, 0.035, and 0.45 μg L(-1), respectively. The precision of the FLA-APGD-OES method was evaluated to be within 2-5% (as the relative standard deviation of the repeated measurements). The method found its application in the determination of the content of Ag, Cd, Hg, Pb, Tl, and Zn in a certified reference material (CRM) of Lobster hepatopancreas (TORT-2), four brass samples as well as mineral water and tea leaves samples spiked with the analytes. In the case of brass samples, a reference method, i.e., inductively coupled plasma optical emission spectrometry (ICP-OES) was used. A good agreement between the results obtained with FLA-APGD-OES and the certified values for the CRM TORT-2 as well as the reference values obtained with ICP-OES for the brass samples was revealed, indicating the good accuracy of the proposed method. The recoveries obtained for the spiked samples of mineral water and tea leaves were within the range of 97.5-102%.
Harun, Norlida; Anderson, Robert A; Miller, Eleanor I
2009-01-01
An ELISA and a liquid chromatography-tandem mass spectrometry (LC-MS-MS) confirmation method were developed and validated for the identification and quantitation of ketamine and its major metabolite norketamine in urine samples. The Neogen ketamine microplate ELISA was optimized with respect to sample and enzyme conjugate volumes and the sample preincubation time before addition of the enzyme conjugate. The ELISA kit was validated to include an assessment of the dose-response curve, intra- and interday precision, limit of detection (LOD), and cross-reactivity. The sensitivity and specificity were calculated by comparison to the results from the validated LC-MS-MS confirmation method. An LC-MS-MS method was developed and validated with respect to LOD, lower limit of quantitation (LLOQ), linearity, recovery, intra- and interday precision, and matrix effects. The ELISA dose-response curve was a typical S-shaped binding curve, with a linear portion of the graph observed between 25 and 500 ng/mL for ketamine. The cross-reactivity of 200 ng/mL norketamine to ketamine was 2.1%, and no cross-reactivity was detected with 13 common drugs tested at 10,000 ng/mL. The ELISA LOD was calculated to be 5 ng/mL. Both intra- (n = 10) and interday (n = 50) precisions were below 5.0% at 25 ng/mL. The LOD for ketamine and norketamine was calculated statistically to be 0.6 ng/mL. The LLOQ values were also calculated statistically and were 1.9 ng/mL and 2.1 ng/mL for ketamine and norketamine, respectively. The test linearity was 0-1200 ng/mL with correlation coefficient (R(2)) > 0.99 for both analytes. Recoveries at 50, 500, and 1000 ng/mL range from 97.9% to 113.3%. Intra- (n = 5) and interday (n = 25) precisions between extracts for ketamine and norketamine were excellent (< 10%). Matrix effects analysis showed an average ion suppression of 5.7% for ketamine and an average ion enhancement of 13.0% for norketamine for urine samples collected from six individuals. A comparison of ELISA and LC-MS-MS results demonstrated a sensitivity, specificity, and efficiency of 100%. These results indicated that a cutoff value of 25 ng/mL ketamine in the ELISA screen is particularly suitable and reliable for urine testing in a forensic toxicology setting. Furthermore, both ketamine and norketamine were detected in all 34 urine samples collected from individuals socializing in pubs by the Royal Malaysian Police. Ketamine concentrations detected by LC-MS-MS ranged from 22 to 31,670 ng/mL, and norketamine concentrations ranged from 25 to 10,990 ng/mL. The concentrations of ketamine and norketamine detected in the samples are most ikely indicative of ketamine abuse.
Pre-oxidation for Colorimetric Sensor Array Detection of VOCs
Lin, Hengwei; Jang, Minseok; Suslick, Kenneth S.
2011-01-01
A disposable pre-oxidation technique is reported that dramatically improves the detection and identification of volatile organic compounds (VOCs) by a colorimetric sensor array. By passing a vapor stream through a tube packed with chromic acid on silica immediately before the colorimetric sensor array, the sensitivity to less reactive VOCs is substantially increased and limits of detection (LODs) are improved ~300-fold, permitting the detection, identification, and discrimination of 20 commonly found indoor VOC pollutants at both their immediately dangerous to life or health (IDLH) and at permissible exposure limits (PEL) concentrations. LODs of these pollutants were on average 1.4% of their respective PELs. PMID:21967478
Rice, Treva; Cooper, Richard S; Wu, Xiaodong; Bouchard, Claude; Rankinen, Tuomo; Rao, D C; Jaquish, Cashell E; Fabsitz, Richard R; Province, Michael A
2006-03-01
In many genetic studies of complex traits, sample sizes are often too small to detect linkages of low-to-moderate effects. However, the combined linkage evidence across several studies can be synthesized using meta-analysis with the aim of providing more definitive support of linkage. In the current study using the National Heart, Lung, and Blood Institute (NHLBI) GeneLink Project, a meta-analysis based on a modification of Fisher's method of pooling P values was used to investigate linkage for systolic blood pressure (SBP) and diastolic blood pressure (DBP) values across three studies involving African American and Nigerian families (HyperGEN, Health, Risk Factors, Exercise Training and Genetics [HERITAGE], and Genetics of Hypertension in Blacks). The meta results suggest two regions (2p and 7p) provide enhanced linkage evidence compared with the individual study results. The maximal meta Lod score of 2.9 on 2p14-p13.1 (64-78 cM) represented approximately 1-Lod unit increase over the respective individual study scores. This general region has been implicated previously involving primarily families of white ethnicity and provides confirmatory evidence that this QTL is common across ethnic groups. The second finding at 7p21.3-p15.3 (8-25 cM) provided a meta Lod of 3.5. Although region was implicated primarily in the Nigerian subjects the low-level but consistent support involving the African American families (individual Lod score of 1.0) suggests a novel QTL with respect to BP variation in individuals of black ethnicity. Follow-up studies involving positional cloning efforts of the combined families showing linkage evidence in these regions (particularly 2p) may be warranted to verify these findings and identify the genes and causative variants.
Salisbury, Craig D C; Sweet, Jason C; Munro, Roger
2004-01-01
A liquid chromatographic method for the determination of sulfachloropyridazine, sulfadiazine, sulfadimethoxine, sulfadoxine, sulfaethoxypyridazine, sulfamethazine, sulfaquinoxaline, and sulfathiazole residues in the muscle, liver, and kidney of food animals using sulfapyridine as internal standard is reported. Tissues are extracted using a modified version of AOAC Official Method 983.31 (Sulfonamide Residues in Animal Tissues). The sample extract is reconstituted in pH 3.0 buffer-acetonitrile (60 + 40) and filtered into an autosampler vial. Using a programmable autosampler of a liquid chromatograph, a portion of the sample is derivatized precolumn with fluorescamine. The sulfonamide derivatives are separated by liquid chromatography using a C18 column with a mobile phase of 0.02M phosphoric acid-acetonitrile (60.5 + 39.5) and detected by fluorescence (excitation, 405 nm; emission, 495 nm). The method was applied to swine and cattle muscle, liver, and kidney; sheep and horse muscle and kidney; and chicken muscle and liver. The mean values for samples fortified with sulfonamides at levels between 0.05 and 0.2 microg/g agreed within 96-99% of spiked levels, with coefficients of variation ranging from 4-10%. The limit of detection (LOD) for all sulfonamides was 0.01 microg/g, with the exception of sulfaquinoxaline, for which the LOD was 0.015 microg/g.
Rasouli, Zolaikha; Ghavami, Raouf
2016-08-05
Vanillin (VA), vanillic acid (VAI) and syringaldehyde (SIA) are important food additives as flavor enhancers. The current study for the first time is devote to the application of partial least square (PLS-1), partial robust M-regression (PRM) and feed forward neural networks (FFNNs) as linear and nonlinear chemometric methods for the simultaneous detection of binary and ternary mixtures of VA, VAI and SIA using data extracted directly from UV-spectra with overlapped peaks of individual analytes. Under the optimum experimental conditions, for each compound a linear calibration was obtained in the concentration range of 0.61-20.99 [LOD=0.12], 0.67-23.19 [LOD=0.13] and 0.73-25.12 [LOD=0.15] μgmL(-1) for VA, VAI and SIA, respectively. Four calibration sets of standard samples were designed by combination of a full and fractional factorial designs with the use of the seven and three levels for each factor for binary and ternary mixtures, respectively. The results of this study reveal that both the methods of PLS-1 and PRM are similar in terms of predict ability each binary mixtures. The resolution of ternary mixture has been accomplished by FFNNs. Multivariate curve resolution-alternating least squares (MCR-ALS) was applied for the description of spectra from the acid-base titration systems each individual compound, i.e. the resolution of the complex overlapping spectra as well as to interpret the extracted spectral and concentration profiles of any pure chemical species identified. Evolving factor analysis (EFA) and singular value decomposition (SVD) were used to distinguish the number of chemical species. Subsequently, their corresponding dissociation constants were derived. Finally, FFNNs has been used to detection active compounds in real and spiked water samples. Copyright © 2016 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Rasouli, Zolaikha; Ghavami, Raouf
2016-08-01
Vanillin (VA), vanillic acid (VAI) and syringaldehyde (SIA) are important food additives as flavor enhancers. The current study for the first time is devote to the application of partial least square (PLS-1), partial robust M-regression (PRM) and feed forward neural networks (FFNNs) as linear and nonlinear chemometric methods for the simultaneous detection of binary and ternary mixtures of VA, VAI and SIA using data extracted directly from UV-spectra with overlapped peaks of individual analytes. Under the optimum experimental conditions, for each compound a linear calibration was obtained in the concentration range of 0.61-20.99 [LOD = 0.12], 0.67-23.19 [LOD = 0.13] and 0.73-25.12 [LOD = 0.15] μg mL- 1 for VA, VAI and SIA, respectively. Four calibration sets of standard samples were designed by combination of a full and fractional factorial designs with the use of the seven and three levels for each factor for binary and ternary mixtures, respectively. The results of this study reveal that both the methods of PLS-1 and PRM are similar in terms of predict ability each binary mixtures. The resolution of ternary mixture has been accomplished by FFNNs. Multivariate curve resolution-alternating least squares (MCR-ALS) was applied for the description of spectra from the acid-base titration systems each individual compound, i.e. the resolution of the complex overlapping spectra as well as to interpret the extracted spectral and concentration profiles of any pure chemical species identified. Evolving factor analysis (EFA) and singular value decomposition (SVD) were used to distinguish the number of chemical species. Subsequently, their corresponding dissociation constants were derived. Finally, FFNNs has been used to detection active compounds in real and spiked water samples.
Sensing cocaine in saliva with infrared laser spectroscopy
NASA Astrophysics Data System (ADS)
Hans, Kerstin M.-C.; Müller, Matthias; Gianella, Michele; Wägli, Ph.; Sigrist, Markus W.
2013-02-01
Increasing numbers of accidents caused by drivers under the influence of drugs, raise drug tests to worldwide interest. We developed a one-step extraction technique for cocaine in saliva and analyzed reference samples with laser spectroscopy employing two different schemes. The first is based on attenuated total reflection (ATR), which is applied to dried samples. The second scheme uses transmission measurements for the analysis of liquid samples. ATR spectroscopy achieved a limit of detection (LOD) of 3μg/ml. The LOD for the transmission approach in liquid samples is < 10 μg/ml. These LODs are realistic as such concentration ranges are encountered in the saliva of drug users after the administration of a single dose of cocaine. An improved stabilization of the set-up should lower the limit of detection significantly.
Chew, Pei Gee; Frost, Fredrick; Mullen, Liam; Fisher, Michael; Zadeh, Heidar; Grainger, Ruth; Albouaini, Khaled; Dodd, James; Patel, Bilal; Velavan, Periaswamy; Kunadian, Babu; Rawat, Anju; Obafemi, Toba; Tong, Sarah; Jones, Julia; Khand, Aleem
2018-02-01
We tested the hypothesis that a single high sensitivity troponin at limits of detection (LOD HSTnT) (<5 ng/l) combined with a presentation non-ischaemic electrocardiogram is superior to low-risk Global Registry of Acute Coronary Events (GRACE) (<75), Thrombolysis in Myocardial Infarction (TIMI) (≤1) and History, ECG, Age, Risk factors and Troponin (HEART) score (≤3) as an aid to early, safe discharge for suspected acute coronary syndrome. In a prospective cohort study, risk scores were computed in consecutive patients with suspected acute coronary syndrome presenting to the Emergency Room of a large English hospital. Adjudication of myocardial infarction, as per third universal definition, involved a two-physician, blinded, independent review of all biomarker positive chest pain re-presentations to any national hospital. The primary and secondary outcome was a composite of type 1 myocardial infarction, unplanned coronary revascularisation and all cause death (MACE) at six weeks and one year. Of 3054 consecutive presentations with chest pain 1642 had suspected acute coronary syndrome (52% male, median age 59 years, 14% diabetic, 20% previous myocardial infarction). Median time from chest pain to presentation was 9.7 h. Re-presentations occurred in eight hospitals with 100% follow-up achieved. Two hundred and eleven (12.9%) and 279 (17%) were adjudicated to suffer MACE at six weeks and one year respectively. Only HEART ≤3 (negative predictive value MACE 99.4%, sensitivity 97.6%, %discharge 53.4) and LOD HSTnT strategy (negative predictive value MACE 99.8%, sensitivity 99.5%, %discharge 36.9) achieved pre-specified negative predictive value of >99% for MACE at six weeks. For type 1 myocardial infarction alone the negative predictive values at six weeks and one year were identical, for both HEART ≤3 and LOD HSTnT at 99.8% and 99.5% respectively. HEART ≤3 or LOD HSTnT strategy rules out short and medium term myocardial infarction with ≥99.5% certainty, and short-term MACE with >99% certainty, allowing for early discharge of 53.4% and 36.9% respectively of suspected acute coronary syndrome. Adoption of either strategy has the potential to greatly reduce Emergency Room pressures and minimise follow-up investigations. Very early presenters (<3 h), due to limited numbers, are excluded from these conclusions.
Mathews, Carol A; Nievergelt, Caroline M; Azzam, Amin; Garrido, Helena; Chavira, Denise A; Wessel, Jennifer; Bagnarello, Monica; Reus, Victor I; Schork, Nicholas J
2007-03-05
To date, only one complete genome screen for obsessive-compulsive disorder (OCD) has been published. That study identified a region of suggestive linkage (maximum lod score of 2.25) with a relatively small sample size (N = 56; 27 with OCD). Additional complete genome screens are needed to confirm this finding and identify other regions of linkage. We present the clinical characteristics and power to detect linkage of 11 multigenerational families with OCD and hoarding (N = 92; 44 with OCD), as well as heritability estimates for several quantitative traits. Families with at least two individuals with OCD were identified through probands with childhood-onset OCD. Expected lod scores were calculated for simulated genetic marker data under an additive and two dominant models assuming a dense SNP marker map. All affected individuals had an early age of onset (18 or younger). Hoarding was present in 46% of subjects. Obsessive-compulsive symptoms and hoarding were highly heritable. The maximum mean expected lod score was 3.31 for OCD and 1.39 for hoarding. We found reasonable power to detect regions of interest (lod = 2) for OCD in these families, but will need to expand our family collection to have adequate power to detect regions of interest for hoarding. (c) 2007 Wiley-Liss, Inc.
Establishment of a Simple and Convenient Method for Folic Acid Enzyme Chemiluminescence Immunoassay
NASA Astrophysics Data System (ADS)
Liu, Ting; Zeng, Ling; Yu, Zhengwei; Yang, Yanfei; Qu, Yunhuan
2018-01-01
The enzyme chemiluminescence new immunoassay for folic acid (FA) was established by competition model. Add FA samples to a microtiter plate precoated with the goat anti-mouse IgG firstly, then add enzyme abled FA and FA monoclonal antibody (McAb). The values of CLIA were measured to reflect the quantity of FA. The limit of detection(LOD) of assay is 0.37ng/mL. The assay shows good correlation during 1∼30 ng/mL with correlation coefficient 0.9976. The intra- and inter-assay coefficients of variation are 4.8 % ∼ 7.3 % and 6.1 % ∼ 12.2 %, respectively. The recovery of folic acid in serum is 90.4 %∼113.2 %. Compared with determine value clinically in chemiluminescence immunoassay kit from Roche company, the correlative equation is y = 0.9689x + 0.0228, and correlation coefficient is 0.9780. Various components and kit overall show good stabilities. This method is simple and convenient, and has low LOD value. The method has overcome the shortcomings of the present references. It is easy to apply and has broad clinical application prospect. It lays an experimental foundation for the preparation of Mc Ab against folic acid and the development of domestic kit.
Schizophrenia: A genome search targets chromosomes 3 and 8 for exploration
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lasseter, V.K.; Pulver, A.E.; Wolyniec, P.
1994-09-01
Using a systematically ascertained sample of 57 families, each having 2 or more members with a consensus diagnosis of schizophrenia (DSM-III-R criteria), we have searched approximately 75% of the genome for susceptibility loci for schizophrenia. Genetic linkage studies of 520 loci have been performed using a complex autosomal dominant model incorporating age-at-onset and certainty of the diagnosis. Results were analyzed under the hypothesis of heterogeneity using the A-test and the Liang test. A two-stage strategy based on lod score thresholds from simulation studies of our sample identified regions for further exploration (hot spots). In each region, a dense map ofmore » highly informative dinucleotide repeat polymorphisms (heterozygosity greater than .70) is analyzed using linkage studies with dominant, recessive, and affected only models and non-parametric sib pair identity-by-descent methods (SIBPAL, S.A.G.E. 2.1). In no region has a lod score > 3 been observed; however, affected sib pair analyses gave a p-value of .0001 corresponding to a lod score > 3. Current {open_quote}hot spots{close_quote} on chromosomes 3p26-p24 and 8p22-p21 will be presented. For 3p26-p24, the maximum two-point lod score is 1.97 (dominant model) and the SIBPAL p-value is .02. For 8p22-p21, the maximum two-point lod score is 2.02 (recessive model) and the SIBPAL p-value is .0001.« less
Tabassum, Rana; Gupta, Banshi D
2017-05-15
We report theoretical and experimental realization of a SPR based fiber optic nicotine sensor having coatings of silver and graphene doped ZnO nanostructure onto the unclad core of the optical fiber. The volume fraction (f) of graphene in ZnO was optimized using simulation of electric field intensity. Four types of graphene doped ZnO nanostructures viz. nanocomposites, nanoflowers, nanotubes and nanofibers were prepared using optimized value of f. The morphology, photoluminescence (PL) spectra and UV-vis spectra of these nanostructures were studied. The peak PL intensity was found to be highest for ZnO: graphene nanofibers. The optimized value of f in ZnO: graphene nanofiber was reconfirmed using UV-vis spectroscopy. The experiments were performed on the fiber optic probe fabricated with Ag/ZnO: graphene layer and optimized parameters for in-situ detection of nicotine. The interaction of nicotine with ZnO: graphene nanostructures alters the dielectric function of ZnO: graphene nanostructure which is manifested in terms of shift in resonance wavelength. From the sensing signal, the performance parameters were measured including sensitivity, limit of detection (LOD), limit of quantification (LOQ), stability, repeatability and selectivity. The real sample prepared using cigarette tobacco leaves and analyzed using the fabricated sensor makes it suitable for practical applications. The achieved values of LOD and LOQ are found to be unrivalled in comparison to the reported ones. The sensor possesses additional advantages such as, immunity to electromagnetic interference, low cost, capability of online monitoring, remote sensing. Copyright © 2017 Elsevier B.V. All rights reserved.
False-Negative Rate and Recovery Efficiency Performance of a Validated Sponge Wipe Sampling Method
Piepel, Greg F.; Boucher, Raymond; Tezak, Matt; Amidan, Brett G.; Einfeld, Wayne
2012-01-01
Recovery of spores from environmental surfaces varies due to sampling and analysis methods, spore size and characteristics, surface materials, and environmental conditions. Tests were performed to evaluate a new, validated sponge wipe method using Bacillus atrophaeus spores. Testing evaluated the effects of spore concentration and surface material on recovery efficiency (RE), false-negative rate (FNR), limit of detection (LOD), and their uncertainties. Ceramic tile and stainless steel had the highest mean RE values (48.9 and 48.1%, respectively). Faux leather, vinyl tile, and painted wood had mean RE values of 30.3, 25.6, and 25.5, respectively, while plastic had the lowest mean RE (9.8%). Results show roughly linear dependences of RE and FNR on surface roughness, with smoother surfaces resulting in higher mean REs and lower FNRs. REs were not influenced by the low spore concentrations tested (3.10 × 10−3 to 1.86 CFU/cm2). Stainless steel had the lowest mean FNR (0.123), and plastic had the highest mean FNR (0.479). The LOD90 (≥1 CFU detected 90% of the time) varied with surface material, from 0.015 CFU/cm2 on stainless steel up to 0.039 on plastic. It may be possible to improve sampling results by considering surface roughness in selecting sampling locations and interpreting spore recovery data. Further, FNR values (calculated as a function of concentration and surface material) can be used presampling to calculate the numbers of samples for statistical sampling plans with desired performance and postsampling to calculate the confidence in characterization and clearance decisions. PMID:22138998
Ostoich, M; Serena, F; Falletti, L; Fantoni, A
2013-01-01
Directive 2000/60/EC requires the achievement of a 'good chemical status' for surface water within pre-established dates. Disinfection is needed to achieve compulsory final microbial limit values (in Italy for wastewater discharges the parameter Escherichia coli - EC - is imposed by law with a maximum limit value of 5,000 cfu/100 mL). Liquid waste and disinfection by-products must be considered when designing appropriate monitoring of dangerous substances; the specific classes of substances must be investigated according to the typology of received wastewaters and liquid wastes (where applicable) and specific analytical techniques, with Limit of Detection (LOD) lower than the limit values, must be applied; the difficulties faced by national and regional environmental control Agencies is that these techniques have to be applied during ordinary activity and not only for research purposes. The study aims to present the control of dangerous substances, as a screening view, in wastewater treatment plant (WWTP) discharges in the province of Venice (Northern Italy) for the period 2007-2010 based on available data from institutional controls. In addition, the wastewater disinfection process with ozone applied to a medium size WWTP (45,000 Population Equivalents) is presented as a case study, with a view to assessing the microbiological abatement efficacy and the presence of dangerous substances. Discharge quality of the WWTPs in the province of Venice presented mean values that were higher than the LOD, but only for certain metals. For the Paese plant, zinc and chloroform were the only micro-pollutants detected with a higher level than the LOD. From microbiological data in the period 2006-2011 the disinfection abatement efficiency for Paese was, in most cases above 99% for EC, faecal coliform (FC), faecal streptococci (FS) while efficiency was slightly lower for total coliform (TC); however, the proposed criterion aimed at respecting 99.99% abatement was not completely satisfied. Therefore, despite the high organic and industrial load of the considered plant and the need to find an alternative system for chlorine, as chlorine disinfection has been banned in the Veneto region since December 2012, ozone efficiency is not completely satisfactory and other systems such as peracetic or performic acids and UV systems must be considered.
Norcocaine in human hair as a biomarker of heavy cocaine use in a high risk population.
Poon, S; Gareri, J; Walasek, P; Koren, G
2014-08-01
In hair analysis, cocaine (COC) and its metabolites have been studied relatively extensively with a consistent focus of distinguishing active drug use and excluding external contamination. Although quantitative cut-offs using major metabolite, benzolecgonine (BE), in hair have been proposed to distinguish likely active use from passive exposure, exogenously formed BE may result in false positive tests. Hence, the presence of less commonly detected COC metabolite, norcocaine (NCOC), may be useful in increasing certainty of illicit COC use and evaluating likelihood of environmental contamination. The objective of the present study was to observe the pattern of NCOC detection in a clinical population of suspected users and evaluate the possible role of NCOC in distinguishing systemic exposure from external contamination to COC and assessing intensity of cocaine use. Hair samples collected between January 2011 and May 2013 from the Motherisk Laboratory were analyzed by GC-MS for the presence of COC, BE, and NCOC. NCOC positivity rates (%) for various COC concentration ranges as well as sensitivity, specificity, positive predictive value, and negative predictive values of NCOC as a biomarker of different COC use profiles was calculated. The rate of NCOC positivity (%) within COC concentration ranges (ng/mg) 0.13-0.4 (above LOD, below LOQ), 0.4-3, 3-6, 6-10, 10-14, >14 were 0.26, 4.15, 29.63, 55.85, 80.37, and 94.02, respectively; p<0.0001 for all positivity comparisons between ranges. These results were used to determine a COC cut-off concentration for differing levels of COC use. The presence of NCOC above the LOD of 0.13 ng/mg predicted COC concentrations exceeding 14.00 ng/mg, with sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of 94.0%, 87.9%, 41.5%, and 99.4%, respectively. The presence NCOC above the LOD of 0.13 ng/mg predicted COC concentrations exceeding the 75th percentile, with sensitivity, specificity, PPV, and NPV of 76.6%, 94.7%, 74.7%, and 95.2%, respectively. Despite an inability to definitively rule out external contamination, the presence of NCOC in hair is strongly associated with elevated COC levels and performs as a highly specific surrogate marker for frequent/intensive cocaine use and highly sensitive marker for intensive/daily use of cocaine. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Boyden, Steven E.; Kunkel, Louis M.
2010-01-01
Background Human lifespan is approximately 25% heritable, and genetic factors may be particularly important for achieving exceptional longevity. Accordingly, siblings of centenarians have a dramatically higher probability of reaching extreme old age than the general population. Methodology/Principal Findings To map the loci conferring a survival advantage, we performed the second genomewide linkage scan on human longevity and the first using a high-density marker panel of single nucleotide polymorphisms. By systematically testing a range of minimum age cutoffs in 279 families with multiple long-lived siblings, we identified a locus on chromosome 3p24-22 with a genomewide significant allele-sharing LOD score of 4.02 (empirical P = 0.037) and a locus on chromosome 9q31-34 with a highly suggestive LOD score of 3.89 (empirical P = 0.054). The empirical P value for the combined result was 0.002. A third novel locus with a LOD score of 4.05 on chromosome 12q24 was detected in a subset of the data, and we also obtained modest evidence for a previously reported interval on chromosome 4q22-25. Conclusions/Significance Our linkage data should facilitate the discovery of both common and rare variants that determine genetic variability in lifespan. PMID:20824210
Adegoke, Oluwasesan; Seo, Min-Woong; Kato, Tatsuya; Kawahito, Shoji; Park, Enoch Y
2016-12-15
Ultrasensitive, rapid and selective diagnostic probes are urgently needed to overcome the limitations of traditional probes for norovirus (NV). Here, we report the detection of NV genogroup II via nucleic acid hybridization technology using a quantum dot (QD)-conjugated molecular beacon (MB) probe. To boost the sensitivity of the MB assay system, an ultrasensitive QD fluorophore with unique optical properties was synthesized, characterized and exploited as a fluorescence signal generator. Alloyed thioglycolic (TGA)-capped CdZnSeS QDs with a high photoluminescence (PL) quantum yield (QY) value of 92% were synthesized, and a modified silanization method was employed to encapsulate the thiol-capped QDs in a silica layer. The resulting highly luminescent alloyed SiO2-coated CdZnSeS QDs had a remarkable PL QY value of 98%. Transmission electron microscopy and dynamic light scattering confirmed the monodispersity of the alloyed nanocrystals, and zeta potential analysis confirmed their colloidal stability. Powder X-ray diffraction and PL lifetime measurements confirmed the surface modification of the QDs. The alloyed TGA-capped and SiO2-coated CdZnSeS QD-conjugated MB bioprobes detected extremely low concentrations of NV RNA. Ultrasensitive detection of low concentrations of NV RNA with a limit of detection (LOD) of 8.2copies/mL in human serum and a LOD of 9.3 copies/mL in buffer was achieved using the SiO2-coated CdZnSeS QD-MB probes, an increase in sensitivity of 3-fold compared with the detection limit for NV RNA using TGA-capped CdZnSeS QD-MBs. The additional merits of our detection system are rapidity, specificity and improved sensitivity over conventional molecular test probes. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.
Burgués, Javier; Jiménez-Soto, Juan Manuel; Marco, Santiago
2018-07-12
The limit of detection (LOD) is a key figure of merit in chemical sensing. However, the estimation of this figure of merit is hindered by the non-linear calibration curve characteristic of semiconductor gas sensor technologies such as, metal oxide (MOX), gasFETs or thermoelectric sensors. Additionally, chemical sensors suffer from cross-sensitivities and temporal stability problems. The application of the International Union of Pure and Applied Chemistry (IUPAC) recommendations for univariate LOD estimation in non-linear semiconductor gas sensors is not straightforward due to the strong statistical requirements of the IUPAC methodology (linearity, homoscedasticity, normality). Here, we propose a methodological approach to LOD estimation through linearized calibration models. As an example, the methodology is applied to the detection of low concentrations of carbon monoxide using MOX gas sensors in a scenario where the main source of error is the presence of uncontrolled levels of humidity. Copyright © 2018 Elsevier B.V. All rights reserved.
Episodic Spin-up and Spin-down Torque on Earth
NASA Astrophysics Data System (ADS)
Slabinski, Victor J.; Mendonca, Antonio A.
2018-04-01
Variations in Earth rotation angle are traditionally expressed by the time difference (ΔT=TT-UT1) between Terrestrial Time (TT) as told by atomic clocks and Universal Time UT1, the time variable used by the Earth-rotation formula. A plot of ΔT versus TT over the past 160 years shows a continuous curve with approximate straight-line segments with different spans of order ~20 years. Removing the tidal and seasonal variations from the data gives these line segments which represent the “decadal variations” in Earth rotation.The slope of a straight-line segment is proportional to the departure of Earth rotation rate from a reference value at the time. The change in slope over the relatively short time between segments indicates an episodic spin-up or spin-down in Earth rotation. The daily combination of VLBI, SLR, and other modern data available since 1973 gives us accurate, daily values of ΔT and the corresponding LOD (Length Of Day) values during these episodes. These allow us to determine the rotational acceleration occurring then.The three largest spin-speed changes found during the VLBI era have the following characteristics:Episode _____________ Duration__ ΔLOD__LOD Rate1983 Dec 30-1984 Jan 28 ... 29 d ...-0.65 ms ..-8.3 ms/y ..........spin-up1989 Mar 15-1989 May 23 ...69 d ....0.68 .......+3.6 ..............spin-down1994 Jan 21-2001 Apr 01 ... 6.5 y ...-2.2 .........-0.36 ..extended spin-upFor the first two episodes listed, we find the acceleration grows from zero (or at least a relatively small value) to its extreme value in ~1 day, stays approximately constant at this value for 29 or 69 days, and then decays back to zero over ~1 day. The acceleration, while it occurs, gives an LOD rate much greater than the 0.02 ms/y rate from tidal friction.The third episode shows that occasionally a several-year-long episode occurs. The acceleration magnitude is smaller but can make a larger total change in LOD (and spin rate). Tidal friction requires >100 y to equal the LOD magnitude change from this episode.We do not know the cause or trigger for the episodes.
Fluorenone based fluorescent probe for selective "turn-on" detection of pyrophosphate and alanine
NASA Astrophysics Data System (ADS)
Daniel Thangadurai, T.; Nithya, I.; Manjubaashini, N.; Bhuvanesh, N.; Bharathi, G.; Nandhakumar, R.; Nataraj, D.
2018-06-01
To sense biologically important entities with different size and dimensions, a fluorenone based fluorescent receptor was designed and synthesized. Probe 1 displayed a distinct fluorescence enhancement emission at 565 nm for pyrophosphate and 530 nm for alanine in polar solvent. The fluorescence titration experiments confirm 1:1 stoichiometric ratio with high-binding constant and very low limit of detection (LoD) values. Receptor 1 showed a highly selective and sensitive recognition to HP2O73 - and to alanine over other competitive anions and amino acids. In addition, the fluorescence lifetime measurement and reversible binding study results support the practical importance of 1.
Forecasting irregular variations of UT1-UTC and LOD data caused by ENSO
NASA Astrophysics Data System (ADS)
Niedzielski, T.; Kosek, W.
2008-04-01
The research focuses on prediction of LOD and UT1-UTC time series up to one-year in the future with the particular emphasis on the prediction improvement during El Nĩ o or La Nĩ a n n events. The polynomial-harmonic least-squares model is applied to fit the deterministic function to LOD data. The stochastic residuals computed as the difference between LOD data and the polynomial- harmonic model reveal the extreme values driven by El Nĩ o or La Nĩ a. These peaks are modeled by the n n stochastic bivariate autoregressive prediction. This approach focuses on the auto- and cross-correlations between LOD and the axial component of the atmospheric angular momentum. This technique allows one to derive more accurate predictions than purely univariate forecasts, particularly during El Nĩ o/La n Nĩ a events. n
Mu, Xihui; Tong, Zhaoyang; Huang, Qibin; Liu, Bing; Liu, Zhiwei; Hao, Lanqun; Dong, Hua; Zhang, Jinping; Gao, Chuan
2016-01-01
Using the multiple advantages of the ultra-highly sensitive electrochemiluminescence (ECL) technique, Staphylococcus protein A (SPA) functionalized gold-magnetic nanoparticles and phage displayed antibodies, and using gold-magnetic nanoparticles coated with SPA and coupled with a polyclonal antibody (pcAb) as magnetic capturing probes, and Ru(bpy)32+-labeled phage displayed antibody as a specific luminescence probe, this study reports a new way to detect ricin with a highly sensitive and specific ECL immunosensor and amplify specific detection signals. The linear detection range of the sensor was 0.0001~200 µg/L, and the limit of detection (LOD) was 0.0001 µg/L, which is 2500-fold lower than that of the conventional ELISA technique. The gold-magnetic nanoparticles, SPA and Ru(bpy)32+-labeled phage displayed antibody displayed different amplifying effects in the ECL immunosensor and can decrease LOD 3-fold, 3-fold and 20-fold, respectively, compared with the ECL immunosensors without one of the three effects. The integrated amplifying effect can decrease the LOD 180-fold. The immunosensor integrates the unique advantages of SPA-coated gold-magnetic nanoparticles that improve the activity of the functionalized capturing probe, and the amplifying effect of the Ru(bpy)32+-labeled phage displayed antibodies, so it increases specificity, interference-resistance and decreases LOD. It is proven to be well suited for the analysis of trace amounts of ricin in various environmental samples with high recovery ratios and reproducibility. PMID:26927130
Plucinski, Mateusz; Dimbu, Rafael; Candrinho, Baltazar; Colborn, James; Badiane, Aida; Ndiaye, Daouda; Mace, Kimberly; Chang, Michelle; Lemoine, Jean F; Halsey, Eric S; Barnwell, John W; Udhayakumar, Venkatachalam; Aidoo, Michael; Rogier, Eric
2017-11-07
Rapid diagnostic test (RDT) positivity is supplanting microscopy as the standard measure of malaria burden at the population level. However, there is currently no standard for externally validating RDT results from field surveys. Individuals' blood concentration of the Plasmodium falciparum histidine rich protein 2 (HRP2) protein were compared to results of HRP2-detecting RDTs in participants from field surveys in Angola, Mozambique, Haiti, and Senegal. A logistic regression model was used to estimate the HRP2 concentrations corresponding to the 50 and 90% level of detection (LOD) specific for each survey. There was a sigmoidal dose-response relationship between HRP2 concentration and RDT positivity for all surveys. Variation was noted in estimates for field RDT sensitivity, with the 50% LOD ranging between 0.076 and 6.1 ng/mL and the 90% LOD ranging between 1.1 and 53 ng/mL. Surveys conducted in two different provinces of Angola using the same brand of RDT and same study methodology showed a threefold difference in LOD. Measures of malaria prevalence estimated using population RDT positivity should be interpreted in the context of potentially large variation in RDT LODs between, and even within, surveys. Surveys based on RDT positivity would benefit from external validation of field RDT results by comparing RDT positivity and antigen concentration.
Screening for Multiple Genes Influencing Dyslexia.
ERIC Educational Resources Information Center
Smith, Shelley D.; And Others
1991-01-01
Examines the "sib pair" method of linkage analysis designed to locate genes influencing dyslexia, which has several advantages over the "LOD" score method. Notes that the sib pair analysis was able to detect the same linkages as the LOD method, plus a possible third region. Confirms that the sib pair method is an effective means of screening. (RS)
Altiokka, G; Atkosar, Z; Can, N O
2002-10-15
A flow injection analysis (FIA) using UV detection, potentiometry and conductometry for levofloxacin (LVF) are described in this study. The best solvent system was found to consist of 0.2 M acetate buffer at pH 3 having 10% MeOH. A flow rate of 1 ml min(-1) was pumped and active material was detected at 288 nm. The detection limit (LOD) and limit of quantification (LOQ) for FIA were calculated to be 3 x 10(-7) M (S/N = 3) and 1 x 10(-7) M (S/N = 10), respectively. In the analysis of tablets, the RSD values were found to be 0.83, 0.98 and 0.99 for FIA, potentiometric and conductometric methods, respectively. Copyright 2002 Elsevier Science B.V.
Zhu, Pengyu; Fu, Wei; Wang, Chenguang; Du, Zhixin; Huang, Kunlun; Zhu, Shuifang; Xu, Wentao
2016-04-15
The possibility of the absolute quantitation of GMO events by digital PCR was recently reported. However, most absolute quantitation methods based on the digital PCR required pretreatment steps. Meanwhile, singleplex detection could not meet the demand of the absolute quantitation of GMO events that is based on the ratio of foreign fragments and reference genes. Thus, to promote the absolute quantitative detection of different GMO events by digital PCR, we developed a quantitative detection method based on duplex digital PCR without pretreatment. Moreover, we tested 7 GMO events in our study to evaluate the fitness of our method. The optimized combination of foreign and reference primers, limit of quantitation (LOQ), limit of detection (LOD) and specificity were validated. The results showed that the LOQ of our method for different GMO events was 0.5%, while the LOD is 0.1%. Additionally, we found that duplex digital PCR could achieve the detection results with lower RSD compared with singleplex digital PCR. In summary, the duplex digital PCR detection system is a simple and stable way to achieve the absolute quantitation of different GMO events. Moreover, the LOQ and LOD indicated that this method is suitable for the daily detection and quantitation of GMO events. Copyright © 2016 Elsevier B.V. All rights reserved.
Mano, Junichi; Hatano, Shuko; Nagatomi, Yasuaki; Futo, Satoshi; Takabatake, Reona; Kitta, Kazumi
2018-03-01
Current genetically modified organism (GMO) detection methods allow for sensitive detection. However, a further increase in sensitivity will enable more efficient testing for large grain samples and reliable testing for processed foods. In this study, we investigated real-time PCR-based GMO detection methods using a large amount of DNA template. We selected target sequences that are commonly introduced into many kinds of GM crops, i.e., 35S promoter and nopaline synthase (NOS) terminator. This makes the newly developed method applicable to a wide range of GMOs, including some unauthorized ones. The estimated LOD of the new method was 0.005% of GM maize events; to the best of our knowledge, this method is the most sensitive among the GM maize detection methods for which the LOD was evaluated in terms of GMO content. A 10-fold increase in the DNA amount as compared with the amount used under common testing conditions gave an approximately 10-fold reduction in the LOD without PCR inhibition. Our method is applicable to various analytical samples, including processed foods. The use of other primers and fluorescence probes would permit highly sensitive detection of various recombinant DNA sequences besides the 35S promoter and NOS terminator.
A Portable Impedance Immunosensing System for Rapid Detection of Salmonella Typhimurium
Wen, Tao; Wang, Ronghui; Sotero, America; Li, Yanbin
2017-01-01
Salmonella Typhimurium is one of the most dangerous foodborne pathogens and poses a significant threat to human health. The objective of this study was to develop a portable impedance immunosensing system for rapid and sensitive detection of S. Typhimurium in poultry. The developed portable impedance immunosensing system consisted of a gold interdigitated array microelectrode (IDAM), a signal acquisitive interface and a laptop computer with LabVIEW software. The IDAM was first functionalized with 16-Mercaptohexadecanoic acid, and streptavidin was immobilized onto the electrode surface through covalent bonding. Then, biotin-labelled S. Typhimurium-antibody was immobilized onto the IDAM surface. Samples were dropped on the surface of the IDAM and the S. Typhimurium cells in the samples were captured by the antibody on the IDAM. This resulted in impedance changes that were measured and displayed with the LabVIEW software. An equivalent circuit of the immunosensor demonstrated that the largest change in impedance was due to the electron-transfer resistance. The equivalent circuit showed an increase of 35% for the electron-transfer resistance value compared to the negative control. The calibration result indicated that the portable impedance immunosensing system could be used to measure the standard impedance elements, and it had a maximum error of measurement of approximately 13%. For pure culture detection, the system had a linear relationship between the impedance change and the logarithmic value of S. Typhimurium cells ranging from 76 to 7.6 × 106 CFU (colony-forming unit) (50 μL)−1. The immunosensor also had a correlation coefficient of 0.98, and a high specificity for detection of S. Typhimurium cells with a limit of detection (LOD) of 102 CFU (50 μL)−1. The detection time from the moment a sample was introduced to the display of the results was 1 h. To conclude, the portable impedance immunosensing system for detection of S. Typhimurium achieved an LOD that is comparable with commercial electrochemical impedance instruments. The developed impedance immunosensor has advantages in portability, low cost, rapid detection and label-free features showing a great potential for in-field detection of foodborne pathogens. PMID:28846643
A Portable Impedance Immunosensing System for Rapid Detection of Salmonella Typhimurium.
Wen, Tao; Wang, Ronghui; Sotero, America; Li, Yanbin
2017-08-28
Salmonella Typhimurium is one of the most dangerous foodborne pathogens and poses a significant threat to human health. The objective of this study was to develop a portable impedance immunosensing system for rapid and sensitive detection of S . Typhimurium in poultry. The developed portable impedance immunosensing system consisted of a gold interdigitated array microelectrode (IDAM), a signal acquisitive interface and a laptop computer with LabVIEW software. The IDAM was first functionalized with 16-Mercaptohexadecanoic acid, and streptavidin was immobilized onto the electrode surface through covalent bonding. Then, biotin-labelled S . Typhimurium -antibody was immobilized onto the IDAM surface. Samples were dropped on the surface of the IDAM and the S . Typhimurium cells in the samples were captured by the antibody on the IDAM. This resulted in impedance changes that were measured and displayed with the LabVIEW software. An equivalent circuit of the immunosensor demonstrated that the largest change in impedance was due to the electron-transfer resistance. The equivalent circuit showed an increase of 35% for the electron-transfer resistance value compared to the negative control. The calibration result indicated that the portable impedance immunosensing system could be used to measure the standard impedance elements, and it had a maximum error of measurement of approximately 13%. For pure culture detection, the system had a linear relationship between the impedance change and the logarithmic value of S . Typhimurium cells ranging from 76 to 7.6 × 10⁶ CFU (colony-forming unit) (50 μL) -1 . The immunosensor also had a correlation coefficient of 0.98, and a high specificity for detection of S . Typhimurium cells with a limit of detection (LOD) of 10² CFU (50 μL) -1 . The detection time from the moment a sample was introduced to the display of the results was 1 h. To conclude, the portable impedance immunosensing system for detection of S . Typhimurium achieved an LOD that is comparable with commercial electrochemical impedance instruments. The developed impedance immunosensor has advantages in portability, low cost, rapid detection and label-free features showing a great potential for in-field detection of foodborne pathogens.
Detecting adulterants in milk with lower cost mid-infrared and Raman spectroscopy
NASA Astrophysics Data System (ADS)
Lee, Changwon; Wang, Wenbo; Wilson, Benjamin K.; Connett, Marie; Keller, Matthew D.
2018-02-01
Adulteration of milk for economic gains is a widespread issue throughout the developing world that can have far-reaching health and nutritional impacts. Milk analysis technologies, such as infrared spectroscopy, can screen for adulteration, but the cost of these technologies has prohibited their use in low resource settings. Recent developments in infrared and Raman spectroscopy hardware have led to commercially available low-cost devices. In this work, we evaluated the performance of two such spectrometers in detecting and quantifying the presence of milk adulterants. Five common adulterants - ammonium sulfate, melamine, sodium bicarbonate, sucrose, and urea, were spiked into five different raw cow and goat milk samples at different concentrations. Collected MIR and Raman spectra were analyzed using partial least squares regression. The limit of detection (LOD) for each adulterant was determined to be in the range of 0.04 to 0.28% (400 to 2800 ppm) using MIR spectroscopy. Raman spectroscopy showed similar LOD's for some of the adulterants, notably those with strong amine group signals, and slightly higher LOD's (up to 1.0%) for other molecules. Overall, the LODs were comparable to other spectroscopic milk analyzers on the market, and they were within the economically relevant concentration range of 100 to 4000 ppm. These lower cost spectroscopic devices therefore appear to hold promise for use in low resource settings.
Huang, Bin; Zhang, Lei; Zhang, Weizheng; Liao, Kang; Zhang, Shihong; Zhang, Zhiquan; Ma, Xingyan; Chen, Jialong; Zhang, Xiuhong; Qu, Pinghua; Wu, Shangwei
2017-01-01
ABSTRACT Rapid and accurate detection and identification of microbial pathogens causing urinary tract infections allow prompt and specific treatment. We optimized specimen processing to maximize the limit of detection (LOD) by matrix-assisted laser desorption ionization–time of flight mass spectrometry (MALDI-TOF MS) and evaluated the capacity of combination of MALDI-TOF MS and urine analysis (UA) for direct detection and identification of bacterial pathogens from urine samples. The optimal volumes of processed urine, formic acid/acetonitrile, and supernatant spotted onto the target plate were 15 ml, 3 μl, and 3 μl, respectively, yielding a LOD of 1.0 × 105 CFU/ml. Among a total of 1,167 urine specimens collected from three hospital centers, 612 (52.4%) and 351 (30.1%) were, respectively, positive by UA and urine culture. Compared with a reference method comprised of urine culture and 16S rRNA gene sequencing, the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of MALDI-TOF MS alone and MALDI-TOF MS coupled with UA were 86.6% versus 93.4% (χ2 = 8.93; P < 0.01), 91.5% versus 96.3% (χ2 = 7.06; P < 0.01), 81.5% versus 96.4% (χ2 = 37.32; P < 0.01), and 94.1% versus 93.1% (χ2 = 0.40; P > 0.05), respectively. No significant performance differences were revealed among the three sites, while specificity and NPV of MALDI-TOF MS for males were significantly higher than those for females (specificity, 94.3% versus 77.3%, χ2 = 44.90, P < 0.01; NPV, 95.5% versus 86.1%, χ2 = 18.85, P < 0.01). Our results indicated that the optimization of specimen processing significantly enhanced analytical sensitivity and that the combination of UA and MALDI-TOF MS provided an accurate and rapid detection and identification of bacterial pathogens directly from urine. PMID:28249997
Huang, Bin; Zhang, Lei; Zhang, Weizheng; Liao, Kang; Zhang, Shihong; Zhang, Zhiquan; Ma, Xingyan; Chen, Jialong; Zhang, Xiuhong; Qu, Pinghua; Wu, Shangwei; Chen, Cha; Tang, Yi-Wei
2017-05-01
Rapid and accurate detection and identification of microbial pathogens causing urinary tract infections allow prompt and specific treatment. We optimized specimen processing to maximize the limit of detection (LOD) by matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) and evaluated the capacity of combination of MALDI-TOF MS and urine analysis (UA) for direct detection and identification of bacterial pathogens from urine samples. The optimal volumes of processed urine, formic acid/acetonitrile, and supernatant spotted onto the target plate were 15 ml, 3 μl, and 3 μl, respectively, yielding a LOD of 1.0 × 10 5 CFU/ml. Among a total of 1,167 urine specimens collected from three hospital centers, 612 (52.4%) and 351 (30.1%) were, respectively, positive by UA and urine culture. Compared with a reference method comprised of urine culture and 16S rRNA gene sequencing, the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of MALDI-TOF MS alone and MALDI-TOF MS coupled with UA were 86.6% versus 93.4% (χ 2 = 8.93; P < 0.01), 91.5% versus 96.3% (χ 2 = 7.06; P < 0.01), 81.5% versus 96.4% (χ 2 = 37.32; P < 0.01), and 94.1% versus 93.1% (χ 2 = 0.40; P > 0.05), respectively. No significant performance differences were revealed among the three sites, while specificity and NPV of MALDI-TOF MS for males were significantly higher than those for females (specificity, 94.3% versus 77.3%, χ 2 = 44.90, P < 0.01; NPV, 95.5% versus 86.1%, χ 2 = 18.85, P < 0.01). Our results indicated that the optimization of specimen processing significantly enhanced analytical sensitivity and that the combination of UA and MALDI-TOF MS provided an accurate and rapid detection and identification of bacterial pathogens directly from urine. Copyright © 2017 American Society for Microbiology.
Sam, Soya S; Caliendo, Angela M; Ingersoll, Jessica; Abdul-Ali, Deborah; Kraft, Colleen S
Timely and precise laboratory diagnosis of Herpes simplex viruses (HSV) is required to guide clinical management. The study evaluated limit of detection (LOD) and performance characteristics of the Aptima HSV 1 & 2 assay in comparison to four assays. The multi-center study compared qualitative detection of HSV-1 and 2 by the Aptima HSV-1 and 2 assay (Hologic) to ELVIS culture, Lyra Direct (Quidel), AmpliVue (Quidel) and a laboratory developed test (LDT). LOD was performed using VTM and STM diluted viral concentrations and clinical performance was evaluated using 505 swab specimens. The Aptima LOD studies performed showed a lower detection limit for STM specimens as 1450 copies/mL and 430 copies/mL for HSV1 and HSV-2 respectively; the LOD for VTM specimens was 9370 copies/mL and 8045 copies/mL for HSV-1 and HSV-2 respectively. When the assays were analyzed based on the positive consensus result established the Aptima had 95% of percent positive agreement (PPA) and 100% negative percent agreement (NPA) for the HSV-1. For the HSV-2, the PPA and NPA for Aptima were 96% and 100% respectively. AmpliVue had 1.8% invalid rate, while Lyra had no invalid results but an inhibition rate of 0.8%. Aptima and LDT did not have any invalid or inhibited results. The results indicate that the Aptima HSV-1 & 2 assay is sensitive and the performance characteristics of the Aptima assay is comparable to the assays analyzed for the detection and differentiation of HSV-1 and 2 from cutaneous and mucocutaneous lesions. Copyright © 2017 Elsevier B.V. All rights reserved.
Liang, Xiaohui; Fang, Xiangyi; Yao, Manwen; Yang, Yucong; Li, Junfeng; Liu, Hongjun; Wang, Linyu
2016-02-01
Direct competitive chemiluminescence immunoassays (CLIA) based on gold-coated magnetic nanospheres (Au-MNPs) were developed for rapid analysis of chloramphenicol (CAP). The Au-MNPs were modified with carboxyl groups and amino groups by 11-mercaptoundecanoic acid (MUA) and cysteamine respectively, and then were respectively conjugated with CAP base and CAP succinate via an activating reaction using 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide hydrochloride (EDC) and N-hydroxysuccinimide (NHS). NSP-DMAE-NHS, a new and effective luminescence reagent, was employed to label anti-CAP antibody (mAb) as a tracer in direct CLIA for CAP detection using a 'homemade' luminescent measurement system that was set up with a photomultiplier tube (PMT) and a photon counting unit linked to a computer. The sensitivities and limits of detection (LODs) of the two methods were obtained and compared according to the inhibition curves. The 50% inhibition concentration (IC50 ) values of the two methods were about 0.044 ng/mL and 0.072 ng/mL respectively and LODs were approximately 0.001 ng/mL and 0.006 ng/mL respectively. To our knowledge, they were much more sensitive than any traditional enzyme-linked immunosorbent assay (ELISA) ever reported. Moreover, the new luminescence reagent NSP-DMAE-NHS is much more sensitive and stable than luminol and its derivatives, contributing to the sensitivity enhancement. Copyright © 2015 John Wiley & Sons, Ltd.
Radioactivity measurements and dosimetric evaluation in meat of wild birds.
Roselli, Carla; Desideri, Donatella; Cantaluppi, Chiara; Ceccotto, Federica; Feduzi, Laura; Meli, Maria Assunta
2017-01-01
The aim of this study was to determine the background activity concentration of natural radionuclides and 137 Cesium (Cs) in meat of 14 migratory birds originating from central and northern Europe. This meat is largely consumed by the Italian population. 40 K, 210 Pb, and 137 Cs were determined by gamma spectrometry and 210 Po by alpha spectrometry. The mean 40 K activity concentration detected was 490 ± 117 Bq/kg dw . In all the samples, 210 Pb was below the limit of detection (LOD), and therefore it was not possible to calculate the ratio 210 Po/ 210 Pb. The 210 Po activity concentration ranged between 0.11 ± 0.02 Bq/kg dw and 6.2 ± 0.93 Bq/kg dw with a mean value of 1.03 ± 1.75 Bq/kg dw . The 137 Cs activity concentration was not detectable or near LOD except in two samples with 45 ± 0.7 Bq/kg dw (wood pigeon, from Italy) and 139.1 ± 1.9 Bq/kg dw (woodcock, from Sweden). The effective dose of 210 Po ingested by consumption of wild birds meat accounts for only 0.01-0.6% of natural radiation exposure in Italy. These data indicate that the meat analyzed was safe.
Genetic heterogeneity in Finnish hereditary prostate cancer using ordered subset analysis
Simpson, Claire L; Cropp, Cheryl D; Wahlfors, Tiina; George, Asha; Jones, MaryPat S; Harper, Ursula; Ponciano-Jackson, Damaris; Tammela, Teuvo; Schleutker, Johanna; Bailey-Wilson, Joan E
2013-01-01
Prostate cancer (PrCa) is the most common male cancer in developed countries and the second most common cause of cancer death after lung cancer. We recently reported a genome-wide linkage scan in 69 Finnish hereditary PrCa (HPC) families, which replicated the HPC9 locus on 17q21-q22 and identified a locus on 2q37. The aim of this study was to identify and to detect other loci linked to HPC. Here we used ordered subset analysis (OSA), conditioned on nonparametric linkage to these loci to detect other loci linked to HPC in subsets of families, but not the overall sample. We analyzed the families based on their evidence for linkage to chromosome 2, chromosome 17 and a maximum score using the strongest evidence of linkage from either of the two loci. Significant linkage to a 5-cM linkage interval with a peak OSA nonparametric allele-sharing LOD score of 4.876 on Xq26.3-q27 (ΔLOD=3.193, empirical P=0.009) was observed in a subset of 41 families weakly linked to 2q37, overlapping the HPCX1 locus. Two peaks that were novel to the analysis combining linkage evidence from both primary loci were identified; 18q12.1-q12.2 (OSA LOD=2.541, ΔLOD=1.651, P=0.03) and 22q11.1-q11.21 (OSA LOD=2.395, ΔLOD=2.36, P=0.006), which is close to HPC6. Using OSA allows us to find additional loci linked to HPC in subsets of families, and underlines the complex genetic heterogeneity of HPC even in highly aggregated families. PMID:22948022
Environment applications for ion mobility spectrometry
NASA Technical Reports Server (NTRS)
Ritchie, Robert K.; Rudolph, Andreas
1995-01-01
The detection of environmentally important polychlorinated aromatics by ion mobility spectrometry (IMS) was investigated. Single polychlorinated biphenyl (PCB) isomers (congeners) having five or more chlorine atoms were reliably detected in isooctane solution at levels of 35 ng with a Barringer IONSCAN ion mobility spectrometer operating in negative mode; limits of detection (LOD) were extrapolated to be in the low ng region. Mixtures of up to four PCB congeners, showing characteristic multiple peaks, and complex commercial mixtures of PCBs (Aroclors) were also detected. Detection of Aroclors in transformer oil was suppressed by the presence of the antioxidant BHT (2,6-di-t-butyl4-methylphenol) in the oil. The wood preservative pentachlorophenol (PCP) was easily detected in recycled wood shavings at levels of 52 ppm with the IONSCAN; the LOD was extrapolated to be in the low ppm region.
Jiang, Jin-Qing; Zhang, Hai-Tang; Zhang, Hui-Hui; Wang, Zi-Liang; Yang, Xue-Feng; Fan, Guo-Ying
2014-08-01
Clopidol is mainly used for the prevention and treatment of coccidiosis, which poses a serious potential hazard to public health, in veterinary medicine. The aim of this study was to prepare monoclonal antibodies (mAbs) against clopidol (CLOP) and develop an immunoassay for detecting CLOP residues in chicken tissues. After derivation, CLOP hapten was conjugated to carrier proteins to synthesize the artificial antigen, and immunized Balb/C mice were employed to screen mAbs. A sensitive hybridoma named C1G3 was screened out and two indirect competitive enzyme-linked immunosorbent assay (icELISA) standard curves were established. For the traditional two-step assay the linear range was from 0.06 to 98 ng mL(-1) , with half-maximal inhibitory concentration (IC50 ) and limit of detection (LOD) values of 2.76 ng mL(-1) and 0.03 ng mL(-1) respectively, while the rapid one-step icELISA had a working range from 0.08 to 102 ng mL(-1) , with IC50 and LOD values of 3.52 ng mL(-1) and 0.03 ng mL(-1) respectively. It was also indicated that a 10-fold dilution in chicken muscles gave an inhibition curve almost the same as that obtained in phosphate-buffered saline. When applied to spiking tests in chicken samples, the correlation coefficient (R(2) ) between concentrations added and measured was 0.9534. The results of this study suggest that the immunoassay described is a promising alternative for screening CLOP residues in biological matrices and is suitable for routine diagnostics. © 2014 Society of Chemical Industry.
Krintus, Magdalena; Kozinski, Marek; Boudry, Pascal; Capell, Nuria Estañ; Köller, Ursula; Lackner, Karl; Lefèvre, Guillaume; Lennartz, Lieselotte; Lotz, Johannes; Herranz, Antonio Mora; Nybo, Mads; Plebani, Mario; Sandberg, Maria B; Schratzberger, Wolfgang; Shih, Jessie; Skadberg, Øyvind; Chargui, Ahmed Taoufik; Zaninotto, Martina; Sypniewska, Grazyna
2014-11-01
International recommendations highlight the superior value of cardiac troponins (cTns) for early diagnosis of myocardial infarction along with analytical requirements of improved precision and detectability. In this multicenter study, we investigated the analytical performance of a new high sensitive cardiac troponin I (hs-cTnI) assay and its 99th percentile upper reference limit (URL). Laboratories from nine European countries evaluated the ARCHITECT STAT high sensitive troponin I (hs-TnI) immunoassay on the ARCHITECT i2000SR/i1000SR immunoanalyzers. Imprecision, limit of blank (LoB), limit of detection (LoD), limit of quantitation (LoQ) linearity of dilution, interferences, sample type, method comparisons, and 99th percentile URLs were evaluated in this study. Total imprecision of 3.3%-8.9%, 2.0%-3.5% and 1.5%-5.2% was determined for the low, medium and high controls, respectively. The lowest cTnI concentration corresponding to a total CV of 10% was 5.6 ng/L. Common interferences, sample dilution and carryover did not affect the hs-cTnI results. Slight, but statistically significant, differences with sample type were found. Concordance between the investigated hs-cTnI assay and contemporary cTnI assay at 99th percentile cut-off was found to be 95%. TnI was detectable in 75% and 57% of the apparently healthy population using the lower (1.1 ng/L) and upper (1.9 ng/L) limit of the LoD range provided by the ARCHITECT STAT hs-TnI package insert, respectively. The 99th percentile values were gender dependent. The new ARCHITECT STAT hs-TnI assay with improved analytical features meets the criteria of high sensitive Tn test and will be a valuable diagnostic tool.
Berggrund, Malin; Ekman, Daniel; Gustavsson, Inger; Sundfeldt, Karin; Olovsson, Matts; Enroth, Stefan; Gyllensten, Ulf
2016-01-01
The indicating FTA elute micro card™ has been developed to collect and stabilize the nucleic acid in biological samples and is widely used in human and veterinary medicine and other disciplines. This card is not recommended for protein analyses, since surface treatment may denature proteins. We studied the ability to analyse proteins in human plasma and vaginal fluid as applied to the indicating FTA elute micro card™ using the sensitive proximity extension assay (PEA). Among 92 proteins in the Proseek Multiplex Oncology Iv2 panel, 87 were above the limit of detection (LOD) in liquid plasma and 56 among 92 above LOD in plasma applied to FTA cards. Washing and protein elution protocols were compared to identify an optimal method. Liquid-based cytology samples showed a lower number of proteins above LOD than FTA cards with vaginal fluid samples applied. Our results demonstrate that samples applied to the indicating FTA elute micro card™ are amendable to protein analyses, given that a sensitive protein detection assay is used. The results imply that biological samples applied to FTA cards can be used for DNA, RNA and protein detection. PMID:28936257
Berggrund, Malin; Ekman, Daniel; Gustavsson, Inger; Sundfeldt, Karin; Olovsson, Matts; Enroth, Stefan; Gyllensten, Ulf
2016-01-01
The indicating FTA elute micro card™ has been developed to collect and stabilize the nucleic acid in biological samples and is widely used in human and veterinary medicine and other disciplines. This card is not recommended for protein analyses, since surface treatment may denature proteins. We studied the ability to analyse proteins in human plasma and vaginal fluid as applied to the indicating FTA elute micro card™ using the sensitive proximity extension assay (PEA). Among 92 proteins in the Proseek Multiplex Oncology Iv2 panel, 87 were above the limit of detection (LOD) in liquid plasma and 56 among 92 above LOD in plasma applied to FTA cards. Washing and protein elution protocols were compared to identify an optimal method. Liquid-based cytology samples showed a lower number of proteins above LOD than FTA cards with vaginal fluid samples applied. Our results demonstrate that samples applied to the indicating FTA elute micro card™ are amendable to protein analyses, given that a sensitive protein detection assay is used. The results imply that biological samples applied to FTA cards can be used for DNA, RNA and protein detection.
Chimeric recombinant antibody fragments in cardiac troponin I immunoassay.
Hyytiä, Heidi; Heikkilä, Taina; Brockmann, Eeva-Christine; Kekki, Henna; Hedberg, Pirjo; Puolakanaho, Tarja; Lövgren, Timo; Pettersson, Kim
2015-03-01
To introduce a novel nanoparticle-based immunoassay for cardiac troponin I (cTnI) utilizing chimeric antibody fragments and to demonstrate that removal of antibody Fc-part and antibody chimerization decrease matrix related interferences. A sandwich-type immunoassay for cTnI based on recombinant chimeric (mouse variable/human constant) antigen binding (cFab) antibodies and intrinsically fluorescent nanoparticles was developed. To test whether using chimeric antibody fragments helps to avoid matrix related interferences, samples (n=39) with known amounts of triglycerides, bilirubin, rheumatoid factor (RF) or human anti-mouse antibodies (HAMAs) were measured with the novel assay, along with a previously published nanoparticle-based research assay with the same antibody epitopes. The limit of detection (LoD) was 3.30ng/L. Within-laboratory precision for 29ng/L and 2819ng/L cTnI were 13.7% and 15.9%, respectively. Regression analysis with Siemens ADVIA Centaur® yielded a slope (95% confidence intervals) of 0.18 (0.17-1.19) and a y-intercept of 1.94 (-1.28-3.91) ng/L. When compared to a previously published nanoparticle-based assay, the novel assay showed substantially reduced interference in the tested interference prone samples, 15.4 vs. 51.3%. A rheumatoid factor containing sample was decreased from 241ng/L to
NASA Astrophysics Data System (ADS)
Khalil, A. A. I.; Morsy, M. A.; El-Deen, H. Z.
2017-11-01
Series of manganese-co-precipitated poly (vinyl alcohol) (PVA) polymer were quantitatively and qualitatively analyzed using laser ablation system (LAS) based on double-pulse laser induced breakdown spectroscopy (DP-LIBS) and electron paramagnetic resonance (EPR) spectroscopy. The collinear nanosecond laser beams of 266 and 1064 nm were optimized to focus on the surface of the PVA polymer target. Both laser beams were employed to estimate the natural properties of the excited Mn-PVA plasma, such as electron number density (Ne), electron temperature (Te), and Mn concentration. Individual transition lines of manganese (Mn), carbon (C), lithium (Li), hydrogen (H) and oxygen (O) atoms are identified based on the NIST spectral database. The results show better responses with DP-LIBS than the single-pulse laser induced breakdown spectroscopy (SP-LIBS). On the other hand, the EPR investigation shows characteristic broad peak of Mn-nano-particles (Mn-NPs) in the range of quantum dots of superparamagnetic materials. The line width (peak-to-peak, ΔHpp) and g-value of the observed Mn-EPR peak are ∼20 mT and 2.0046, respectively. The intensities of Mn-emission line at a wavelength 403.07 nm and the Mn-EPR absorption peak were used to accurate quantify the Mn-content in the polymer matrix. The results produce linear trends within the studied concentration range with regression coefficient (R2) value of ∼0.99, and limit of detection (LOD) of 0.026 mol.% and 0.016 mol.%, respectively. The LOD values are at a fold change of about -0.2 of the studied lowest mol.%. The proposed protocols of trace element detection are of significant advantage and can be applied to the other metal analysis.
Complete genomic screen in Parkinson disease: evidence for multiple genes.
Scott, W K; Nance, M A; Watts, R L; Hubble, J P; Koller, W C; Lyons, K; Pahwa, R; Stern, M B; Colcher, A; Hiner, B C; Jankovic, J; Ondo, W G; Allen, F H; Goetz, C G; Small, G W; Masterman, D; Mastaglia, F; Laing, N G; Stajich, J M; Slotterbeck, B; Booze, M W; Ribble, R C; Rampersaud, E; West, S G; Gibson, R A; Middleton, L T; Roses, A D; Haines, J L; Scott, B L; Vance, J M; Pericak-Vance, M A
2001-11-14
The relative contribution of genes vs environment in idiopathic Parkinson disease (PD) is controversial. Although genetic studies have identified 2 genes in which mutations cause rare single-gene variants of PD and observational studies have suggested a genetic component, twin studies have suggested that little genetic contribution exists in the common forms of PD. To identify genetic risk factors for idiopathic PD. Genetic linkage study conducted 1995-2000 in which a complete genomic screen (n = 344 markers) was performed in 174 families with multiple individuals diagnosed as having idiopathic PD, identified through probands in 13 clinic populations in the continental United States and Australia. A total of 870 family members were studied: 378 diagnosed as having PD, 379 unaffected by PD, and 113 with unclear status. Logarithm of odds (lod) scores generated from parametric and nonparametric genetic linkage analysis. Two-point parametric maximum parametric lod score (MLOD) and multipoint nonparametric lod score (LOD) linkage analysis detected significant evidence for linkage to 5 distinct chromosomal regions: chromosome 6 in the parkin gene (MLOD = 5.07; LOD = 5.47) in families with at least 1 individual with PD onset at younger than 40 years, chromosomes 17q (MLOD = 2.28; LOD = 2.62), 8p (MLOD = 2.01; LOD = 2.22), and 5q (MLOD = 2.39; LOD = 1.50) overall and in families with late-onset PD, and chromosome 9q (MLOD = 1.52; LOD = 2.59) in families with both levodopa-responsive and levodopa-nonresponsive patients. Our data suggest that the parkin gene is important in early-onset PD and that multiple genetic factors may be important in the development of idiopathic late-onset PD.
NASA Astrophysics Data System (ADS)
Harris, C. D.; Profeta, Luisa T. M.; Akpovo, Codjo A.; Johnson, Lewis; Stowe, Ashley C.
2017-05-01
A calibration model was created to illustrate the detection capabilities of laser ablation molecular isotopic spectroscopy (LAMIS) discrimination in isotopic analysis. The sample set contained boric acid pellets that varied in isotopic concentrations of 10B and 11B. Each sample set was interrogated with a Q-switched Nd:YAG ablation laser operating at 532 nm. A minimum of four band heads of the β system B2∑ -> Χ2∑transitions were identified and verified with previous literature on BO molecular emission lines. Isotopic shifts were observed in the spectra for each transition and used as the predictors in the calibration model. The spectra along with their respective 10/11B isotopic ratios were analyzed using Partial Least Squares Regression (PLSR). An IUPAC novel approach for determining a multivariate Limit of Detection (LOD) interval was used to predict the detection of the desired isotopic ratios. The predicted multivariate LOD is dependent on the variation of the instrumental signal and other composites in the calibration model space.
Bakker, Eric; Pretsch, Ernö
2008-01-01
Potentiometric sensors share unique characteristics that set them apart from other electrochemical sensors. Potentiometric nanoelectrodes have been reported and successfully used for many decades, and we review these developments. Current research chiefly focuses on nanoscale films at the outer or the inner side of the membrane, with outer layers for increasing biocompatibility, expanding the sensor response, or improving the limit of detection (LOD). Inner layers are mainly used for stabilizing the response and eliminating inner aqueous contacts or undesired nanoscale layers of water. We also discuss the ultimate detectability of ions with such sensors and the power of coupling the ultra-low LODs of ion-selective electrodes with nanoparticle labels to give attractive bioassays that can compete with state-of-the-art electrochemical detection.
McEwen, I; Mulloy, B; Hellwig, E; Kozerski, L; Beyer, T; Holzgrabe, U; Wanko, R; Spieser, J-M; Rodomonte, A
2008-12-01
Oversulphated Chondroitin Sulphate (OSCS) and Dermatan Sulphate (DS) in unfractionated heparins can be identified by nuclear magnetic resonance spectrometry (NMR). The limit of detection (LoD) of OSCS is 0.1% relative to the heparin content. This LoD is obtained at a signal-to-noise ratio (S/N) of 2000:1 of the heparin methyl signal. Quantification is best obtained by comparing peak heights of the OSCS and heparin methyl signals. Reproducibility of less than 10% relative standard deviation (RSD) has been obtained. The accuracy of quantification was good.
Macias, Michael S; Guerra-Diaz, Patricia; Almirall, José R; Furton, Kenneth G
2010-02-25
Currently, in the field of odor detection, there is generally a wider variation in limit of detections (LODs) for canines than instruments. The study presented in this paper introduces an improved protocol for the creation of controlled odor mimic permeation system (COMPS) devices for use as standards in canine training and discusses the canine detection thresholds of piperonal, a starting material for the illicit drug 3,4-methylenedioxymethamphetamine (MDMA), when exposed to these devices. Additionally, this paper describes the first-ever reported direct comparison of solid phase microextraction-ion mobility spectrometry (SPME-IMS) to canine detection for the MDMA odorant, piperonal. The research presented shows the reliability of COMPS devices as low cost field calibrants providing a wide range of odorant concentrations for biological and instrumental detectors. The canine LOD of piperonal emanating from the 100 ng s(-1) COMPS was found to be 1 ng as compared to the SPME-IMS LOD of piperonal in a static, closed system at 2 ng, with a linear dynamic range from 2 ng to 11 ng. The utilization of the COMPS devices would allow for training that will reduce the detection variability between canines and maintain improved consistency for training purposes. Since both SPME and IMS are field portable technologies, it is expected that this coupled method will be useful as a complement to canine detection for the field detection of MDMA. 2009 Elsevier Ireland Ltd. All rights reserved.
Hernández-Borges, Javier; Ravelo-Pérez, Lidia M; Hernández-Suárez, Estrella M; Carnero, Aurelio; Rodríguez-Delgado, Miguel Angel
2007-09-21
In this work an analytical method for the determination of abamectin residues in avocados is developed using high-performance liquid chromatography (HPLC) with fluorescence (FL) detection. A pre-column derivatization with trifluoroacetic anhydride (TFAA) and N-methylimidazole (NMIM) was carried out. The mobile phase consisted of water, methanol and acetonitrile (5:47.5:47.5 v/v/v) and was pumped at a rate of 1 mL/min (isocratic elution). The fluorescence detector was set at an excitation wavelength of 365 nm and an emission wavelength of 470 nm. Homogenized avocado samples were extracted twice with acetonitrile:water 8:2 (v/v) and cleaned using C(18) solid-phase extraction (SPE) cartridges. Recovery values were in the range 87-98% with RSD values lower than 13%. The limits of detection (LODs) and quantification (LOQs) of the whole method were 0.001 and 0.003 mg/kg, respectively. These values are lower than the maximum residue limit (MRL) established by the European Union (EU) and the Spanish legislation in avocado samples.
Lemire, Sharon W; Barr, John R; Ashley, David L; Olson, Carl T; Hayes, Timothy L
2004-01-01
The nitrogen mustards bis(2-chloroethyl)ethylamine (HN1), bis(2-chloroethyl)methylamine (HN2), and tris(2-chloroethyl)amine (HN3) have the potential to be used as chemical terrorism agents because of their extreme vesicant properties. We modified a previously reported method to incorporate automated solid-phase extraction, improve chromatography, and include the urinary metabolite for HN3. The improved method was used to measure levels of the urinary metabolites N-ethyldiethanolamine (EDEA), N-methyldiethanolamine (MDEA), and triethanolamine (TEA) in rats dosed with HN1, HN2, and HN3, respectively, and to establish background levels of EDEA, MDEA, and TEA in human urine samples from a population with no known exposure to nitrogen mustards. Rat dosing experiments confirmed that EDEA, MDEA, and TEA could be detected in urine for at least 48 h after exposure to HN1, HN2, and HN3, respectively. Substantial amounts of EDEA (89 ng/mL), MDEA (170 ng/mL), and TEA (1105 ng/mL) were measured in the urine of rats exposed to 10 mg HN1, HN2, and HN3, respectively, 48 h after exposure. The background concentrations for TEA in the human population ranged from below the limit of detection (LOD 3 ng/mL) to approximately 6500 ng/mL. Neither EDEA (LOD 0.4 ng/mL) nor MDEA (LOD 0.8 ng/mL) was detected above the LOD in the human samples.
Selection of affinity peptides for interference-free detection of cholera toxin.
Lim, Jong Min; Heo, Nam Su; Oh, Seo Yeong; Ryu, Myung Yi; Seo, Jeong Hyun; Park, Tae Jung; Huh, Yun Suk; Park, Jong Pil
2018-01-15
Cholera toxin is a major virulent agent of Vibrio cholerae, and it can rapidly lead to severe dehydration, shock, causing death within hours without appropriate clinical treatments. In this study, we present a method wherein unique and short peptides that bind to cholera toxin subunit B (CTX-B) were selected through M13 phage display. Biopanning over recombinant CTX-B led to rapid screening of a unique peptide with an amino acid sequence of VQCRLGPPWCAK, and the phage-displayed peptides analyzed using ELISA, were found to show specific affinities towards CTX-B. To address the use of affinity peptides in development of the biosensor, sequences of newly selected peptides were modified and chemically synthesized to create a series of affinity peptides. Performance of the biosensor was studied using plasmonic-based optical techniques: localized surface plasmon resonance (LSPR) and surface-enhanced Raman scattering (SERS). The limit of detection (LOD) obtained by LSPR with 3σ-rule was 1.89ng/mL, while SERS had a LOD of 3.51pg/mL. In both cases, the sensitivity was much higher than the previously reported values, and our sensor system was specific towards actual CTX-B secreted from V. cholera, but not for CTX-AB 5 . Copyright © 2017 Elsevier B.V. All rights reserved.
Jiang, Lingxi; Yang, Litao; Rao, Jun; Guo, Jinchao; Wang, Shu; Liu, Jia; Lee, Seonghun; Zhang, Dabing
2010-02-01
To implement genetically modified organism (GMO) labeling regulations, an event-specific analysis method based on the junction sequence between exogenous integration and host genomic DNA has become the preferential approach for GMO identification and quantification. In this study, specific primers and TaqMan probes based on the revealed 5'-end junction sequence of GM cotton MON15985 were designed, and qualitative and quantitative polymerase chain reaction (PCR) assays were established employing the designed primers and probes. In the qualitative PCR assay, the limit of detection (LOD) was 0.5 g kg(-1) in 100 ng total cotton genomic DNA, corresponding to about 17 copies of haploid cotton genomic DNA, and the LOD and limit of quantification (LOQ) for quantitative PCR assay were 10 and 17 copies of haploid cotton genomic DNA, respectively. Furthermore, the developed quantitative PCR assays were validated in-house by five different researchers. Also, five practical samples with known GM contents were quantified using the developed PCR assay in in-house validation, and the bias between the true and quantification values ranged from 2.06% to 12.59%. This study shows that the developed qualitative and quantitative PCR methods are applicable for the identification and quantification of GM cotton MON15985 and its derivates.
Study of the matrimonial structure of the population of central Sardinia (Italy).
Vona, G; Francalacci, P; Paoli, G; Latini, V; Salis, M
1996-12-01
Temporal changes in the matrimonial structure of four Sardinian populations (Bitti, Lula, Lodè and Gavoi) have been studied. The endogamy rates and the average marriage distances indicate that the four villages experienced a long period of isolation. Only in recent decades endogamous marriages have fallen shortly. The trends of marital isonymy and inbreeding, evaluated both from isonymy and dispensation for consanguineous marriages, are similar to those of endogamy. The kinship values between pairs of populations show some preferential relationship (Bitti-Lodè, Lodè-Lula) and an evident differentiation between Gavoi and Bitti. The results also indicate that the values of kinship are not associated with the geographic distances. The possible impact of the matrimonial structure on the genetic structure and the relationships among the studied populations will be examined in further investigations, in which the genetic markers will be considered.
Novel versatile smart phone based Microplate readers for on-site diagnoses.
Fu, Qiangqiang; Wu, Ze; Li, Xiuqing; Yao, Cuize; Yu, Shiting; Xiao, Wei; Tang, Yong
2016-07-15
Microplate readers are important diagnostic instruments, used intensively for various readout test kits (biochemical analysis kits and ELISA kits). However, due to their expensive and non-portability, commercial microplate readers are unavailable for home testing, community and rural hospitals, especially in developing countries. In this study, to provide a field-portable, cost-effective and versatile diagnostic tool, we reported a novel smart phone based microplate reader. The basic principle of this devise relies on a smart phone's optical sensor that measures transmitted light intensities of liquid samples. To prove the validity of these devises, developed smart phone based microplate readers were applied to readout results of various analytical targets. These targets included analanine aminotransferase (ALT; limit of detection (LOD) was 17.54 U/L), alkaline phosphatase (AKP; LOD was 15.56 U/L), creatinine (LOD was 1.35μM), bovine serum albumin (BSA; LOD was 0.0041mg/mL), prostate specific antigen (PSA; LOD was 0.76pg/mL), and ractopamine (Rac; LOD was 0.31ng/mL). The developed smart phone based microplate readers are versatile, portable, and inexpensive; they are unique because of their ability to perform under circumstances where resources and expertize are limited. Copyright © 2016 Elsevier B.V. All rights reserved.
Bojanić, Krunoslav; Midwinter, Anne Camilla; Marshall, Jonathan Craig; Rogers, Lynn Elizabeth; Biggs, Patrick Jon; Acke, Els
2016-08-01
Campylobacter enteritis in humans is primarily associated with C. jejuni/coli infection. The impact of other Campylobacter spp. is likely to be underestimated due to the bias of culture methods towards Campylobacter jejuni/coli diagnosis. Stool antigen tests are becoming increasingly popular and appear generally less species-specific. A review of independent studies of the ProSpecT® Campylobacter Microplate enzyme immunoassay (EIA) developed for C. jejuni/coli showed comparable diagnostic results to culture methods but the examination of non-jejuni/coli Campylobacter spp. was limited and the limit-of-detection (LOD), where reported, varied between studies. This study investigated LOD of EIA for Campylobacter upsaliensis, Campylobacter hyointestinalis and Campylobacter helveticus spiked in human stools. Multiple stools and Campylobacter isolates were used in three different concentrations (10(4)-10(9)CFU/ml) to reflect sample heterogeneity. All Campylobacter species evaluated were detectable by EIA. Multivariate analysis showed LOD varied between Campylobacter spp. and faecal consistency as fixed effects and individual faecal samples as random effects. EIA showed excellent performance in replicate testing for both within and between batches of reagents, in agreement between visual and spectrophotometric reading of results, and returned no discordance between the bacterial concentrations within independent dilution test runs (positive results with lower but not higher concentrations). This study shows how limitations in experimental procedures lead to an overestimation of consistency and uniformity of LOD for EIA that may not hold under routine use in diagnostic laboratories. Benefits and limitations for clinical practice and the influence on estimates of performance characteristics from detection of multiple Campylobacter spp. by EIA are discussed. Copyright © 2016 Elsevier B.V. All rights reserved.
Curtis, David; Knight, Jo; Sham, Pak C
2005-09-01
Although LOD score methods have been applied to diseases with complex modes of inheritance, linkage analysis of quantitative traits has tended to rely on non-parametric methods based on regression or variance components analysis. Here, we describe a new method for LOD score analysis of quantitative traits which does not require specification of a mode of inheritance. The technique is derived from the MFLINK method for dichotomous traits. A range of plausible transmission models is constructed, constrained to yield the correct population mean and variance for the trait but differing with respect to the contribution to the variance due to the locus under consideration. Maximized LOD scores under homogeneity and admixture are calculated, as is a model-free LOD score which compares the maximized likelihoods under admixture assuming linkage and no linkage. These LOD scores have known asymptotic distributions and hence can be used to provide a statistical test for linkage. The method has been implemented in a program called QMFLINK. It was applied to data sets simulated using a variety of transmission models and to a measure of monoamine oxidase activity in 105 pedigrees from the Collaborative Study on the Genetics of Alcoholism. With the simulated data, the results showed that the new method could detect linkage well if the true allele frequency for the trait was close to that specified. However, it performed poorly on models in which the true allele frequency was much rarer. For the Collaborative Study on the Genetics of Alcoholism data set only a modest overlap was observed between the results obtained from the new method and those obtained when the same data were analysed previously using regression and variance components analysis. Of interest is that D17S250 produced a maximized LOD score under homogeneity and admixture of 2.6 but did not indicate linkage using the previous methods. However, this region did produce evidence for linkage in a separate data set, suggesting that QMFLINK may have been able to detect a true linkage which was not picked up by the other methods. The application of model-free LOD score analysis to quantitative traits is novel and deserves further evaluation of its merits and disadvantages relative to other methods.
Ulgen, Ayse; Han, Zhihua; Li, Wentian
2003-12-31
We address the question of whether statistical correlations among quantitative traits lead to correlation of linkage results of these traits. Five measured quantitative traits (total cholesterol, fasting glucose, HDL cholesterol, blood pressure, and triglycerides), and one derived quantitative trait (total cholesterol divided by the HDL cholesterol) are used for phenotype correlation studies. Four of them are used for linkage analysis. We show that although correlation among phenotypes partially reflects the correlation among linkage analysis results, the LOD-score correlations are on average low. The most significant peaks found by using different traits do not often overlap. Studying covariances at specific locations in LOD scores may provide clues for further bivariate linkage analyses.
Herrera, Victoria L M; Pasion, Khristine A; Moran, Ann Marie; Ruiz-Opazo, Nelson
2013-01-01
The prevalence of hypertension increases after menopause with 75% of postmenopausal women developing hypertension in the United States, along with hypertensive end organ diseases. While human and animal model studies have indicated a protective role for estrogen against cardiovascular disease and glomerulosclerosis, clinical studies of hormone replacement therapy in postmenopausal women have shown polar results with some improvement in hypertension but worsening of hypertensive kidney disease, or no effect at all. These observations suggest that the pathogenesis of postmenopausal hypertension and its target organ complications is more complex than projected, and that loss of endogenous estrogens induces epigenetic changes that alter genetic susceptibility to end-organ complications per se resulting in pathogenetic mechanisms beyond correction by hormone replacement. We studied postmenopausal-induced changes in renal disease and performed a total genome scan for quantitative trait loci (QTLs) affecting kidney disease in postmenopausal 16m-old F2[Dahl S x R]-intercross female rats. We used glomerular injury score (GIS) as quantitative trait. We compared QTLs amongst premenopausal, ovariectomized and postmenopausal F2[Dahl S x R]-intercross rats using identical phenotype characterization. Postmenopausal F2[Dahl S x R]-intercross rats exhibited increased hypertensive glomerulosclerosis (P<0.01) and equivalent levels of kidney disease when compared to premenopausal and ovariectomized F2[Dahl S x R]-intercross rats respectively. We detected three significant to highly significant GIS-QTLs (GIS-pm1 on chromosome 4, LOD 3.54; GIS-pm2 on chromosome 3, LOD 2.72; GIS-pm3 on chromosome 5, LOD 2.37) and two suggestive GIS-QTLs (GIS-pm4 on chromosome 2, LOD 1.70; GIS-pm5 on chromosome 7, LOD 1.28), all of which were unique to this postmenopausal population. Detection of increased renal disease phenotype in postmenopausal and ovariectomized subjects suggests a protective role of ovarian hormones. Furthermore, the detection of distinct GIS-QTLs in postmenopausal intercross female rats suggests that distinct genetic mechanisms underlie hypertensive glomerulosclerosis in premenopausal and postmenopausal states.
Herrera, Victoria L. M.; Pasion, Khristine A.; Moran, Ann Marie; Ruiz-Opazo, Nelson
2013-01-01
The prevalence of hypertension increases after menopause with 75% of postmenopausal women developing hypertension in the United States, along with hypertensive end organ diseases. While human and animal model studies have indicated a protective role for estrogen against cardiovascular disease and glomerulosclerosis, clinical studies of hormone replacement therapy in postmenopausal women have shown polar results with some improvement in hypertension but worsening of hypertensive kidney disease, or no effect at all. These observations suggest that the pathogenesis of postmenopausal hypertension and its target organ complications is more complex than projected, and that loss of endogenous estrogens induces epigenetic changes that alter genetic susceptibility to end-organ complications per se resulting in pathogenetic mechanisms beyond correction by hormone replacement. We studied postmenopausal-induced changes in renal disease and performed a total genome scan for quantitative trait loci (QTLs) affecting kidney disease in postmenopausal 16m-old F2[Dahl S x R]-intercross female rats. We used glomerular injury score (GIS) as quantitative trait. We compared QTLs amongst premenopausal, ovariectomized and postmenopausal F2[Dahl S x R]-intercross rats using identical phenotype characterization. Postmenopausal F2[Dahl S x R]-intercross rats exhibited increased hypertensive glomerulosclerosis (P<0.01) and equivalent levels of kidney disease when compared to premenopausal and ovariectomized F2[Dahl S x R]-intercross rats respectively. We detected three significant to highly significant GIS-QTLs (GIS-pm1 on chromosome 4, LOD 3.54; GIS-pm2 on chromosome 3, LOD 2.72; GIS-pm3 on chromosome 5, LOD 2.37) and two suggestive GIS-QTLs (GIS-pm4 on chromosome 2, LOD 1.70; GIS-pm5 on chromosome 7, LOD 1.28), all of which were unique to this postmenopausal population. Detection of increased renal disease phenotype in postmenopausal and ovariectomized subjects suggests a protective role of ovarian hormones. Furthermore, the detection of distinct GIS-QTLs in postmenopausal intercross female rats suggests that distinct genetic mechanisms underlie hypertensive glomerulosclerosis in premenopausal and postmenopausal states. PMID:23393608
Wang, W L; Darwin, W D; Cone, E J
1994-10-14
As part of an ongoing research program on the development of drug detection methodology, we developed an assay for the simultaneous measurement of cocaine, heroin and metabolites in plasma, saliva, urine and hair by solid-phase extraction (SPE) and gas chromatography-mass spectrometry (GC-MS). The analytes that could be measured by this assay were the following: anhydroecgonine methyl ester; ecgonine methyl ester;. ecgonine ethyl ester; cocaine; cocaethylene; benzoylecgonine; cocaethylene; norcocaethylene; benzoylnorecgonine; codeine; morphine; norcodeine; 6-acetylmorphine; normorphine; and heroin. Liquid specimens were diluted, filtered and then extracted by SPE. Additional handling steps were necessary for the analysis of hair samples. An initial wash procedure was utilized to remove surface contaminants. Washed hair samples were extracted with methanol overnight at 40 degrees C. Both wash and extract fractions were collected, evaporated and purified by SPE. All extracts were evaporated, derivatized with N,O-bis(trimethylsilyl)trifluoroacetamide (BSTFA) with 1% trimethylchlorosilane (TMCS) and analyzed by GC-MS. The limit of detection (LOD) for cocaine, heroin and metabolites in biological specimens was approximately 1 ng/ml with the exception of norcodeine, normorphine and benzoylnorecgonine (LOD = 5 ng/ml). The LOD for cocaine, heroin and metabolites in hair was approximately 0.1 ng/mg of hair with the exception of norcodeine (LOD = 0.3 ng/mg) and normorphine and benzoylnorecgonine (LOD = 0.5 ng/mg). Coefficients of variation ranged from 3 to 26.5% in the hair assay. This assay has been successfully utilized in research on the disposition of cocaine, heroin and metabolites in hair, plasma, saliva and urine and in treatment studies.
Kane, Peter F; Hall, William L
2006-01-01
There is increasing regulatory interest in the non-nutritive metals content of fertilizer materials, but at present there is no consensus analytical method for acid digestion and instrument detection of those elements in fertilizer matrixes. This lack of method standardization has resulted in unacceptable variability of results between fertilizer laboratories performing metals analysis. A method has been developed using microwave digestion with nitric acid at 200 degrees C, followed by inductively coupled plasma-optical emission spectrometry instrument detection, for the elements arsenic, cadmium, cobalt, chromium, molybdenum, nickel, lead, and selenium. The method has been collaboratively studied, and statistical results are here reported. Fourteen collaborators were sent 62 sample materials in a blind duplicate design. Materials represented a broad cross section of fertilizer types, including phosphate ore, manufactured phosphate products, N-P-K blends, organic fertilizers, and micro-nutrient materials. As much as possible within the limit of the number of samples, materials were selected from different regions of the United States and the world. Limit of detection (LOD) was determined using synthetic fertilizers consisting of reagent grade chemicals with near zero levels of the non-nutritive elements, analyzed blindly. Samples with high iron content caused the most variability between laboratories. Most samples reasonably above LOD gave HorRat values within the range 0.5 to 2.0, indicating acceptable method performance according to AOAC guidelines for analyses in the mg/kg range. The method is recommended for AOAC Official First Action status.
Fernández, Fátima; Pinacho, Daniel G; Sánchez-Baeza, Francisco; Marco, M Pilar
2011-05-11
An inexpensive and portable surface plasmon resonance (SPR) sensor, SPReeta Evaluation Kit SPR3, has been used to develop a biosensor for the determination of fluoroquinolone antibiotics (FQs) and to demonstrate its performance analyzing FQ residues in milk samples. The SPReeta three-channel gold chips were activated with a mixed self-assembled monolayer (m-SAM) and functionalized with a FQ haptenized protein. Binding of the antibody produced a concentration-dependent increase of the SPR signal as a result of the change in the refraction index. Similarly, the presence of the FQ produced a dose-dependent decrease of the response, which allowed a good limit of detection (LOD) to be obtained (1.0 ± 0.4 μg L(-1) for enrofloxacin in buffer). The response was reproducible in all three channels, on different injections and days, and also between chips. Milk samples could be analyzed after a simple sample treatment involving fat removal by centrifugation and dilution with water. Under these conditions calibration curves were obtained showing that FQ residues can be analyzed in milk samples with an IC(50) value of 26.4 ± 7.2 μg L(-1) and a LOD of 2.0 ± 0.2 μg L(-1) (for enrofloxacin), far below the European Union regulations for this antibiotic family in this matrix. Finally, the paper also demonstrates that the biosensor is able to selectively detect the presence of FQs in milk samples, even in the presence of other antibiotics. Enrofloxacin, ciprofloxacin, and norfloxacin residues were detected in blind samples supplied by Nestlé Co.
Zhu, Jiali; Sun, Shan; Jiang, Kai; Wang, Yuhui; Liu, Wenqing; Lin, Hengwei
2017-11-15
Herein, a highly sensitive and selective fluorimetric nanoprobe for peroxynitrite (ONOO - ) detection based on photoinduced electron transfer (PET) from ferrocene (Fc) to carbon dots (CDs) is reported. The nanoprobe (named CDs-Fc) can be facilely constructed through covalently conjugating CDs and ferrocenecarboxylic acid. Further studies reveal that the energy level of highest occupied molecular orbital (HOMO) of the CDs is lowered with the addition of ONOO - due to its oxidation and nitration capabilities. Thus, an efficient electron transfer from Fc to the excited states of CDs could occur, leading to obvious fluorescence quenching. The fluorescence quenching of the nanoprobe was determined to be peroxynitrite concentrations dependence with a linear range between 4nM to 0.12μM. Thanks to the excellent optical properties of the CDs and efficient electron transfer efficiency from Fc to the excited CDs, the nanoprobe exhibits very high sensitivity to ONOO - with a limit of detection (LOD) of 2.9nM. To the best of our knowledge, this LOD is the highest reported value till today for the detection of peroxynitrite. Besides, the nanoprobe also shows excellent selectivity to ONOO - among a broad range of substances, even including other reactive oxygen/nitrogen species (ROS/RNS). Finally, the nanoprobe was verified to be very low cytotoxicity, and was successfully applied for intracellular ONOO - detection. This work would provide a promising tool for the research of ONOO - in cytobiology and disease diagnosis. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Sharkawi, K.-H.; Abdul-Rahman, A.
2013-09-01
Cities and urban areas entities such as building structures are becoming more complex as the modern human civilizations continue to evolve. The ability to plan and manage every territory especially the urban areas is very important to every government in the world. Planning and managing cities and urban areas based on printed maps and 2D data are getting insufficient and inefficient to cope with the complexity of the new developments in big cities. The emergence of 3D city models have boosted the efficiency in analysing and managing urban areas as the 3D data are proven to represent the real world object more accurately. It has since been adopted as the new trend in buildings and urban management and planning applications. Nowadays, many countries around the world have been generating virtual 3D representation of their major cities. The growing interest in improving the usability of 3D city models has resulted in the development of various tools for analysis based on the 3D city models. Today, 3D city models are generated for various purposes such as for tourism, location-based services, disaster management and urban planning. Meanwhile, modelling 3D objects are getting easier with the emergence of the user-friendly tools for 3D modelling available in the market. Generating 3D buildings with high accuracy also has become easier with the availability of airborne Lidar and terrestrial laser scanning equipments. The availability and accessibility to this technology makes it more sensible to analyse buildings in urban areas using 3D data as it accurately represent the real world objects. The Open Geospatial Consortium (OGC) has accepted CityGML specifications as one of the international standards for representing and exchanging spatial data, making it easier to visualize, store and manage 3D city models data efficiently. CityGML able to represents the semantics, geometry, topology and appearance of 3D city models in five well-defined Level-of-Details (LoD), namely LoD0 to LoD4. The accuracy and structural complexity of the 3D objects increases with the LoD level where LoD0 is the simplest LoD (2.5D; Digital Terrain Model (DTM) + building or roof print) while LoD4 is the most complex LoD (architectural details with interior structures). Semantic information is one of the main components in CityGML and 3D City Models, and provides important information for any analyses. However, more often than not, the semantic information is not available for the 3D city model due to the unstandardized modelling process. One of the examples is where a building is normally generated as one object (without specific feature layers such as Roof, Ground floor, Level 1, Level 2, Block A, Block B, etc). This research attempts to develop a method to improve the semantic data updating process by segmenting the 3D building into simpler parts which will make it easier for the users to select and update the semantic information. The methodology is implemented for 3D buildings in LoD2 where the buildings are generated without architectural details but with distinct roof structures. This paper also introduces hybrid semantic-geometric 3D segmentation method that deals with hierarchical segmentation of a 3D building based on its semantic value and surface characteristics, fitted by one of the predefined primitives. For future work, the segmentation method will be implemented as part of the change detection module that can detect any changes on the 3D buildings, store and retrieve semantic information of the changed structure, automatically updates the 3D models and visualize the results in a userfriendly graphical user interface (GUI).
Further evidence for the increased power of LOD scores compared with nonparametric methods.
Durner, M; Vieland, V J; Greenberg, D A
1999-01-01
In genetic analysis of diseases in which the underlying model is unknown, "model free" methods-such as affected sib pair (ASP) tests-are often preferred over LOD-score methods, although LOD-score methods under the correct or even approximately correct model are more powerful than ASP tests. However, there might be circumstances in which nonparametric methods will outperform LOD-score methods. Recently, Dizier et al. reported that, in some complex two-locus (2L) models, LOD-score methods with segregation analysis-derived parameters had less power to detect linkage than ASP tests. We investigated whether these particular models, in fact, represent a situation that ASP tests are more powerful than LOD scores. We simulated data according to the parameters specified by Dizier et al. and analyzed the data by using a (a) single locus (SL) LOD-score analysis performed twice, under a simple dominant and a recessive mode of inheritance (MOI), (b) ASP methods, and (c) nonparametric linkage (NPL) analysis. We show that SL analysis performed twice and corrected for the type I-error increase due to multiple testing yields almost as much linkage information as does an analysis under the correct 2L model and is more powerful than either the ASP method or the NPL method. We demonstrate that, even for complex genetic models, the most important condition for linkage analysis is that the assumed MOI at the disease locus being tested is approximately correct, not that the inheritance of the disease per se is correctly specified. In the analysis by Dizier et al., segregation analysis led to estimates of dominance parameters that were grossly misspecified for the locus tested in those models in which ASP tests appeared to be more powerful than LOD-score analyses.
Biobarcode assay for the oral anticoagulant acenocoumarol.
Broto, Marta; Salvador, J Pablo; Galve, Roger; Marco, M Pilar
2018-02-01
A novel approach for therapeutic drug monitoring of oral anticoagulants (OA) in clinical samples is reported, based on a NP-based biobarcode assay. The proposed strategy uses specific antibodies for acenocumarol (ACL) covalently bound to magnetic particles (pAb236-MP) and a bioconjugate competitor (hACL-BSA) linked to encoded polystyrene probes (hACL-BSA-ePSP) on a classical competitive immunochemical format. By using this scheme ACL can be detected in low nM range (LOD, 0.96 ± 0.26, N = 3, in buffer) even in complex samples such as serum or plasma (LOD 4 ± 1). The assay shows a high reproducibility (%CV 1.1 day-to-day) and is robust, as it is demonstrated by the fact that ACL can be quantified in complex biological samples with a very good accuracy (slope = 0.97 and R 2 = 0.91, of the linear regression obtained when analyzing spiked vs measured values). Moreover, we have demonstrated that the biobarcode approach has the potential to overcome one of the main challenges of the multiplexed diagnostic, which is the possibility to measure in a single run biomarker targets present at different concentration ranges. Thus, it has been proven that the signal and the detectability can be modulated by just modifying the oligonucleotide load of the encoded probes. This fact opens the door for combining in the same assay encoded probes with the necessary oligonucleotide load to achieve the detectability required for each biomarker target. Copyright © 2017 Elsevier B.V. All rights reserved.
Cai, Zhongyu; Sasmal, Aniruddha; Liu, Xinyu; Asher, Sanford A
2017-10-27
Lectin proteins, such as the highly toxic lectin protein, ricin, and the immunochemically important lectin, jacalin, play significant roles in many biological functions. It is highly desirable to develop a simple but efficient method to selectively detect lectin proteins. Here we report the development of carbohydrate containing responsive hydrogel sensing materials for the selective detection of lectin proteins. The copolymerization of a vinyl linked carbohydrate monomer with acrylamide and acrylic acid forms a carbohydrate hydrogel that shows specific "multivalent" binding to lectin proteins. The resulting carbohydrate hydrogels are attached to 2-D photonic crystals (PCs) that brightly diffract visible light. This diffraction provides an optical readout that sensitively monitors the hydrogel volume. We utilize lactose, galactose, and mannose containing hydrogels to fabricate a series of 2-D PC sensors that show strong selective binding to the lectin proteins ricin, jacalin, and concanavalin A (Con A). This binding causes a carbohydrate hydrogel shrinkage which significantly shifts the diffraction wavelength. The resulting 2-D PC sensors can selectively detect the lectin proteins ricin, jacalin, and Con A. These unoptimized 2-D PC hydrogel sensors show a limit of detection (LoD) of 7.5 × 10 -8 M for ricin, a LoD of 2.3 × 10 -7 M for jacalin, and a LoD of 3.8 × 10 -8 M for Con A, respectively. This sensor fabrication approach may enable numerous sensors for the selective detection of numerous lectin proteins.
NASA Astrophysics Data System (ADS)
Goueguel, Christian; Laville, Stéphane; Loudyi, Hakim; Chaker, Mohamed; Sabsabi, Mohamad; Vidal, François
2008-06-01
Laser-Induced Breakdown Spectroscopy (LIBS) technique combined with Laser-Induced Fluorescence (LIF) is known to be a high sensitivity and high selectivity analytical technique. Although sub-ppm limits of detection (LoD) have already been demonstrated, there is still a constant and urgent need to reach lower LoDs. Here, we report results obtained for the detection of lead trace in brass samples. The plasma was produced by a Q-switched Nd:YAG laser at 1064 nm and then re-excited by a nanosecond optical parametric oscillator (OPO) laser tuned at 283.31 nm. Emission from Pb atoms was then observed at 405.78 nm. The experiments were performed in air at atmospheric pressure. We found out that the optimal conditions were obtained for an ablation fluence of 2-3 J/cm2 and inter-pulse delay of 8-10 μs. Also, excitation energy of about 200 μJ was required to maximize the Pb(I) 405.78 nm emission. Using the LIBS-LIFS technique, the LoD was estimated to be about 180 ppb over 100 laser shots, which corresponds to an improvement of about two orders of magnitude with that obtained using conventional LIBS.
NASA Astrophysics Data System (ADS)
Zhong, Xiaoqin; Qiao, Liang; Stauffer, Géraldine; Liu, Baohong; Girault, Hubert H.
2018-03-01
A polyimide microfluidic chip with a microhole emitter (Ø 10-12 μm) created on top of a microchannel by scanning laser ablation has been designed for nanoelectrospray ionization (spyhole-nanoESI) to couple microfluidics with mass spectrometry. The spyhole-nanoESI showed higher sensitivity compared to standard ESI and microESI from the end of the microchannel. The limits of detection (LOD) for peptide with the spyhole-nanoESI MS reached 50 pM, which was 600 times lower than that with standard ESI. The present microchip emitter allows the analysis of small volumes of samples. As an example, a small cell lung cancer biomarker, neuron-specific enolase (NSE), was detected by monitoring the transition of its unique peptide with the spyhole-nanoESI MS/MS. NSE at 0.2 nM could be well identified with a signal to noise ratio (S/N) of 50, and thereby its LOD was estimated to be 12 pM. The potential application of the spyhole-nanoESI MS/MS in cancer diagnosis was further demonstrated with the successful detection of 2 nM NSE from 1 μL of human serum. Before the detection, the serum sample spiked with NSE was first depleted with immune spin column, then desalted by centrifugal filter device, and finally digested by trypsin, without any other complicated preparation steps. The concentration matched the real condition of clinical samples. In addition, the microchips can be disposable to avoid any cross contamination. The present technique provides a highly efficient way to couple microfluidics with MS, which brings additional values to various microfluidics and MS-based analysis.
Immunofluorescence detection of pea protein in meat products.
Petrášová, Michaela; Pospiech, Matej; Tremlová, Bohuslava; Javůrková, Zdeňka
2016-08-01
In this study we developed an immunofluorescence method to detect pea protein in meat products. Pea protein has a high nutritional value but in sensitive individuals it may be responsible for causing allergic reactions. We produced model meat products with various additions of pea protein and flour; the detection limit (LOD) of the method for pea flour was 0.5% addition, and for pea protein it was 0.001% addition. The repeatabilities and reproducibilities for samples both positive and negative for pea protein were all 100%. In a blind test with model products and commercial samples, there was no statistically significant difference (p > 0.05) between the declared concentrations of pea protein and flour and the immunofluorescence method results. Sensitivity was 1.06 and specificity was 1.00. These results show that the immunofluorescence method is suitable for the detection of pea protein in meat products.
Fukushi, Keiichi; Ito, Hideyuki; Kimura, Kenichi; Yokota, Kuriko; Saito, Keiitsu; Chayama, Kenji; Takeda, Sahori; Wakida, Shin-ichi
2006-02-17
We developed capillary zone electrophoresis (CZE) with direct UV detection for determination of ammonium in environmental water samples. Ammonium in the samples was partly converted into ammonia in the alkaline background electrolyte (BGE) during migration and was detected by molecular absorption of ammonia at 190 nm in approximately 7 min. The limit of detection (LOD) for ammonium was 0.24 mg/l (as nitrogen) at a signal-to-noise ratio of three. The respective values of the relative standard deviation (RSD) of peak area, peak height, and migration time for ammonium were 2.1, 1.8, and 0.46%. Major alkali and alkaline earth metal ions coexisting in the samples did not interfere with ammonium determination by the proposed method. The proposed method determined ammonium in surface water and sewage samples. The results were compared to those obtained using ion chromatography (IC).
Rapid and Highly Sensitive Detection of Lead Ions in Drinking Water Based on a Strip Immunosensor
Kuang, Hua; Xing, Changrui; Hao, Changlong; Liu, Liqiang; Wang, Libing; Xu, Chuanlai
2013-01-01
In this study, we have first developed a rapid and sensitive strip immunosensor based on two heterogeneously-sized gold nanoparticles (Au NPs) probes for the detection of trace lead ions in drinking water. The sensitivity was 4-fold higher than that of the conventional LFA under the optimized conditions. The visual limit of detection (LOD) of the amplified method for qualitative detection lead ions was 2 ng/mL and the LOD for semi-quantitative detection could go down to 0.19 ng/mL using a scanning reader. The method suffered from no interference from other metal ions and could be used to detect trace lead ions in drinking water without sample enrichment. The recovery of the test samples ranged from 96% to 103%. As the detection method could be accomplished within 15 min, this method could be used as a potential tool for preliminary monitoring of lead contamination in drinking water. PMID:23539028
Selective Detection of Peptide-Oligonucleotide Heteroconjugates Utilizing Capillary HPLC-ICPMS
NASA Astrophysics Data System (ADS)
Catron, Brittany; Caruso, Joseph A.; Limbach, Patrick A.
2012-06-01
A method for the selective detection and quantification of peptide:oligonucleotide heteroconjugates, such as those generated by protein:nucleic acid cross-links, using capillary reversed-phase high performance liquid chromatography (cap-RPHPLC) coupled with inductively coupled plasma mass spectrometry detection (ICPMS) is described. The selective detection of phosphorus as 31P+, the only natural isotope, in peptide-oligonucleotide heteroconjugates is enabled by the elemental detection capabilities of the ICPMS. Mobile phase conditions that allow separation of heteroconjugates while maintaining ICPMS compatibility were investigated. We found that trifluoroacetic acid (TFA) mobile phases, used in conventional peptide separations, and hexafluoroisopropanol/triethylamine (HFIP/TEA) mobile phases, used in conventional oligonucleotide separations, both are compatible with ICPMS and enable heteroconjugate separation. The TFA-based separations yielded limits of detection (LOD) of ~40 ppb phosphorus, which is nearly seven times lower than the LOD for HFIP/TEA-based separations. Using the TFA mobile phase, 1-2 pmol of a model heteroconjugate were routinely separated and detected by this optimized capLC-ICPMS method.
Malhotra, Alka; Igo, Robert P; Thameem, Farook; Kao, W H Linda; Abboud, Hanna E; Adler, Sharon G; Arar, Nedal H; Bowden, Donald W; Duggirala, Ravindranath; Freedman, Barry I; Goddard, Katrina A B; Ipp, Eli; Iyengar, Sudha K; Kimmel, Paul L; Knowler, William C; Kohn, Orly; Leehey, David; Meoni, Lucy A; Nelson, Robert G; Nicholas, Susanne B; Parekh, Rulan S; Rich, Stephen S; Chen, Yii-Der I; Saad, Mohammed F; Scavini, Marina; Schelling, Jeffrey R; Sedor, John R; Shah, Vallabh O; Taylor, Kent D; Thornley-Brown, Denyse; Zager, Philip G; Horvath, Amanda; Hanson, Robert L
2009-11-01
Previous studies have shown that in addition to environmental influences, type 2 diabetes mellitus (T2DM) has a strong genetic component. The goal of the current study is to identify regions of linkage for T2DM in ethnically diverse populations. Phenotypic and genotypic data were obtained from African American (AA; total number of individuals [N] = 1004), American Indian (AI; N = 883), European American (EA; N = 537), and Mexican American (MA; N = 1634) individuals from the Family Investigation of Nephropathy and Diabetes. Non-parametric linkage analysis, using an average of 4404 SNPs, was performed in relative pairs affected with T2DM in each ethnic group. In addition, family-based tests were performed to detect association with T2DM. Statistically significant evidence for linkage was observed on chromosome 4q21.1 (LOD = 3.13; genome-wide p = 0.04) in AA. In addition, a total of 11 regions showed suggestive evidence for linkage (estimated at LOD > 1.71), with the highest LOD scores on chromosomes 12q21.31 (LOD = 2.02) and 22q12.3 (LOD = 2.38) in AA, 2p11.1 (LOD = 2.23) in AI, 6p12.3 (LOD = 2.77) in EA, and 13q21.1 (LOD = . 2.24) in MA. While no region overlapped across all ethnic groups, at least five loci showing LOD > 1.71 have been identified in previously published studies. The results from this study provide evidence for the presence of genes affecting T2DM on chromosomes 4q, 12q, and 22q in AA; 6p in EA; 2p in AI; and 13q in MA. The strong evidence for linkage on chromosome 4q in AA provides important information given the paucity of diabetes genetic studies in this population.
NASA Astrophysics Data System (ADS)
Liu, Genyou; Duan, Pengshuo; Hao, Xiaoguang; Hu, Xiaogang
2015-04-01
The previous studies indicated that the most of the interannual variations in Length-Of-Day (LOD) could be explained by the joint effects of ENSO (EI Nino-Southern Oscillations) and QBO (Quasi-Biennial Oscillation) phenomenon in the atmosphere. Due to the limit of the used methods, those results cannot give the 'time-frequency' coherence spectrum between ENSO and LOD, and cannot indicate in which specific periods the weak coherence occurred and difficult to give the reliable reason. This paper uses Daubechies wavelet with 10 order vanishing moment to analyze the LOD monthly time series from 1962 to 2011. Based on cross-wavelet and wavelet coherence methods, the analysis of the time-frequency correlations between ENSO and LOD series (1962-2011) on the 1.3~10.7 year scales is given. We have extracted and reconstructed the LOD signals on 1.3~10.7year scales. The result shows that there is obvious weak coherence on both biennial and 5~8 year scales after 1982 relative to before 1982. According to the previous works, the biennial weak coherence is due to QBO, but the weak coherence on 5~8 year scales cannot be interpreted by the effects of ENSO and QBO. In this study, the Geomagnetic field signals (can be characterized as Aa index) are introduced, we have further extracted and reconstructed the LOD, ENSO and Aa signals in 5-8.0 year band using wavelet packet analysis. Through analyzing the standardized series of the three signals, we found a linear time-frequency formula among the original observation series: LOD(t,f) =αENSO(t,f) +βAa(t,f). This study indicates that the LOD signals on 5.3~8.0 year scales can be expressed in term of linear combination of ENSO and Aa signals. Especially after 1982, the contributions of ENSO and Aa to LOD respectively reach about 0.95ms and 1.0ms.The results also imply that there is an obvious Geomagnetic field signal in interannual variations of LOD. Furthermore, after considering the geomagnetic field signal correction, the Pearson correlation coefficient between LOD and ENSO will increase from 0.51 to 0.98. Consequently, we can conclude that the weak coherence after 1982 on 5.3-8.0 year scales between LOD and ENSO is mainly due to the disturbance of Aa signal, and the observed LOD series is the result of the interaction between ENSO and geomagnetic field signals.
A rapid tool for determination of titanium dioxide content in white chickpea samples.
Sezer, Banu; Bilge, Gonca; Berkkan, Aysel; Tamer, Ugur; Hakki Boyaci, Ismail
2018-02-01
Titanium dioxide (TiO 2 ) is a widely used additive in foods. However, in the scientific community there is an ongoing debate on health concerns about TiO 2 . The main goal of this study is to determine TiO 2 content by using laser induced breakdown spectroscopy (LIBS). To this end, different amounts of TiO 2 was added to white chickpeas and analyzed by using LIBS. Calibration curve was obtained by following Ti emissions at 390.11nm for univariate calibration, and partial least square (PLS) calibration curve was obtained by evaluating the whole spectra. The results showed that Ti calibration curve at 390.11nm provides successful determination of Ti level with 0.985 of R 2 and 33.9ppm of limit of detection (LOD) value, while PLS has 0.989 of R 2 and 60.9ppm of LOD. Furthermore, commercial white chickpea samples were used to validate the method, and validation R 2 for simple calibration and PLS were calculated as 0.989 and 0.951, respectively. Copyright © 2017 Elsevier Ltd. All rights reserved.
UV Spectrophotometric Determination and Validation of Hydroquinone in Liposome.
Khoshneviszadeh, Rabea; Fazly Bazzaz, Bibi Sedigheh; Housaindokht, Mohammad Reza; Ebrahim-Habibi, Azadeh; Rajabi, Omid
2015-01-01
The method has been developed and validated for the determination of hydroquinone in liposomal formulation. The samples were dissolved in methanol and evaluated in 293 nm. The validation parameters such as linearity, accuracy, precision, specificity, limit of detection (LOD) and limit of quantitation (LOQ) were determined. The calibration curve was linear in 1-50 µg/mL range of hydroquinone analyte with a regression coefficient of 0.9998. This study showed that the liposomal hydroquinone composed of phospholipid (7.8 %), cholesterol (1.5 %), alpha ketopherol (0.17 %) and hydroquinone (0.5 %) did not absorb wavelength of 293 nm if it diluted 500 times by methanol. The concentration of hydroquinone reached 10 µg/mL after 500 times of dilution. Furthermore, various validation parameters as per ICH Q2B guideline were tested and found accordingly. The recovery percentages of liposomal hydroquinone were found 102 ± 0.8, 99 ± 0.2 and 98 ± 0.4 for 80%, 100% and 120% respectively. The relative standard deviation values of inter and intra-day precisions were <%2. LOD and LOQ were 0.24 and 0.72 µg/mL respectively.
Measurement of methionine level with the LC-ESI-MS/MS method in schizophrenic patients.
Kulaksizoglu, S; Kulaksizoglu, B; Ellidag, H Y; Eren, E; Yilmaz, N; Baykal, A
2016-01-01
The purpose of this study was to evaluate plasma methionine levels by using liquid chromatography electrospray ionization-tandem mass spectroscopy (LC-ESI-MS/MS) in schizophrenic patients. A twelve-point standard graph was drawn, and the recovery rate, the intra-day and inter-day coefficients of variation (CV), the limit of detection (LOD), and the limit of quantification (LOQ) were evaluated. The y and R2 values of the standard graph equation were determined as 0.011x + 0.0179 and 0.9989, respectively, and the graph remained linear until the 200 µmol/l level. The intra-day coefficients of variation of the samples (n = 10) containing 8, 28, and 58 µmol/l methionine were determined as 2.68, 3.10, and 3.79%, respectively; while their inter-day coefficients of variation were determined as 2.98, 3.19, and 3.84%. The LOD and LOQ values were determined as 0.04 and 0.1 µmol/l, respectively, while the mean recovery rates were determined as 101.7 and 99.3%. Plasma methionine values were measured as 21.5 (19.5-24,6) µmol/l for the patient group, 17.8 (16.3-20.1) µmol/l for the control group, and the difference between the two groups was statistically significant (p = 0.03). LC-ESI-MS/MS method represents a fairly sensitive, economic, and rapid analysis that requires very little sample and is suitable for measuring methionine levels in schizophrenic patients.
NASA Astrophysics Data System (ADS)
Fırat, Merve; Bakırdere, Sezgin; Fındıkoğlu, Maral Selin; Kafa, Emine Betül; Yazıcı, Elif; Yolcu, Melda; Büyükpınar, Çağdaş; Chormey, Dotse Selali; Sel, Sabriye; Turak, Fatma
2017-03-01
This study was performed to develop a sensitive analytical method for the determination of cadmium by slotted quartz tube-flame atomic absorption spectrometry (SQT-FAAS) after dispersive liquid-liquid microextraction (DLLME). The parameters affecting the cadmium complex formation and its extraction output were optimized to obtain high extraction efficiency. These included the pH and amount of the buffer solution, and the concentration of the ligand. The DLLME method was comprehensively optimized based on the type and amount of extraction solvent, dispersive solvent and salt. The type and period of mixing needed for a more effective extraction was also investigated. In order to further improve the sensitivity for the determination of cadmium, the flame atomic absorption spectrometry was fitted with a slotted quartz tube to increase the residence time of cadmium atoms in the pathway of incident light from a hollow cathode lamp. The limits of detection and quantitation (LOD and LOQ) for the FAAS were found to be 42 and 140 μg L- 1, respectively. Under the optimum conditions, LOD and LOQ of the FAAS after DLLME were calculated as 1.3 and 4.4 μg L- 1, respectively. Combining both optimized parameters of the DLLME and SQT-FAAS gave 0.5 and 1.5 μg L- 1 as LOD and LOQ, respectively. Accuracy of the method was also checked using a wastewater certified reference material (EU-L-2), and the result was in good agreement with the certified value.
NASA Astrophysics Data System (ADS)
Gergely, Felicián; Osán, János; Szabó, B. Katalin; Török, Szabina
2016-02-01
Laboratory-scale microscopic X-ray fluorescence (micro-XRF) plays an increasingly important role in various fields where multielemental investigations of samples are indispensable. In case of geological samples, the reasonable detection limits (LOD) and spatial resolutions are necessary to identify the trace element content in microcrystalline level. The present study focuses on the analytical performance of a versatile laboratory-scale micro-XRF system with various options of X-ray sources and detectors to find the optimal experimental configuration in terms of sensitivities and LOD for selected elements in loaded petrographic thin sections. The method was tested for sorption studies involving thin sections prepared from cores of Boda Claystone Formation, which is a potential site for a high-level radioactive waste repository. Loaded ions in the sorption measurements were Cs(I) and Ni(II) chemically representing fission and corrosion products. Based on the collected elemental maps, the correlation between the elements representative of main rock components and the selected loaded ion was studied. For the elements of interest, Cs(I) and Ni(II) low-power iMOXS source with polycapillary and silicon drift detector was found to be the best configuration to reach the optimal LOD values. Laboratory micro-XRF was excellent to identify the responsible key minerals for the uptake of Cs(I). In case of nickel, careful corrections were needed because of the relatively high Ca content of the rock samples. The results were compared to synchrotron radiation micro-XRF.
Characterization and Validation of the LT-SYS Copper Assay on a Roche Cobas 8000 c502 Analyzer.
Kraus, F Bernhard; Mischereit, Marlies; Eller, Christoph; Ludwig-Kraus, Beatrice
2017-02-01
Validation of the LT-SYS quantitative in vitro copper assay on a Roche Cobas 8000 c502 analyzer and comparison with a BIOMED assay on a Roche Cobas Mira analyzer. Imprecision and bias were quantified at different concentration levels (serum and plasma) over a 20-day period. Linearity was assessed covering a range from 4.08 µmol/L to 33.8 µmol/L. Limit of blank (LoB) and limit of detection (LoD) were established based on a total of 120 blank and low-level samples. The method comparison was based on 58 plasma samples. Within-run imprecision ranged from 0.7% to 1.2% and within-laboratory imprecision from 1.4% to 3.3%. Relative bias for the 2 serum pools with known target values was less than 2.5%. The assay did not deviate from linearity over the tested measuring range. LoB and LoD were 0.12 µmol/L and 0.23 µmol/L, respectively. The method comparison revealed an average deviation of 11.5% (2.016 µmol/L), and the linear regression fit was y = 1.464 + 0.795x. The LT-SYS copper assay characterized in this study showed a fully acceptable performance with good degrees of imprecision and bias, no deviation from linearity in the relevant measuring rangem, and very low LoB and LoD. © American Society for Clinical Pathology, 2016. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Mahbub, Parvez; Zakaria, Philip; Guijt, Rosanne; Macka, Mirek; Dicinoski, Greg; Breadmore, Michael; Nesterenko, Pavel N
2015-10-01
The applicability of acid degradation of organic peroxides into hydrogen peroxide in a pneumatically driven flow injection system with chemiluminescence reaction with luminol and Cu(2+) as a catalyst (FIA-CL) was investigated for the fast and sensitive detection of organic peroxide explosives (OPEs). The target OPEs included hexamethylene triperoxide diamine (HMTD), triacetone triperoxide (TATP) and methylethyl ketone peroxide (MEKP). Under optimised conditions maximum degradations of 70% and 54% for TATP and HMTD, respectively were achieved at 162 µL min(-1), and 9% degradation for MEKP at 180 µL min(-1). Flow rates were precisely controlled in this single source pneumatic pressure driven multi-channel FIA system by model experiments on mixing of easily detectable component solutions. The linear range for detection of TATP, HMTD and H2O2 was 1-200 µM (r(2)=0.98-0.99) at both flow rates, while that for MEKP was 20-200 µM (r(2)=0.97) at 180 µL min(-1). The detection limits (LODs) obtained were 0.5 µM for TATP, HMTD and H2O2 and 10 µM for MEKP. The detection times varied from 1.5 to 3 min in this FIA-CL system. Whilst the LOD for H2O2 was comparable with those reported by other investigators, the LODs and analysis times for TATP and HMTD were superior, and significantly, this is the first time the detection of MEKP has been reported by FIA-CL. Copyright © 2015 Elsevier B.V. All rights reserved.
Browne, Richard W; Whitcomb, Brian W
2010-07-01
Problems in the analysis of laboratory data commonly arise in epidemiologic studies in which biomarkers subject to lower detection thresholds are used. Various thresholds exist including limit of detection (LOD), limit of quantification (LOQ), and limit of blank (LOB). Choosing appropriate strategies for dealing with data affected by such limits relies on proper understanding of the nature of the detection limit and its determination. In this paper, we demonstrate experimental and statistical procedures generally used for estimating different detection limits according to standard procedures in the context of analysis of fat-soluble vitamins and micronutrients in human serum. Fat-soluble vitamins and micronutrients were analyzed by high-performance liquid chromatography with diode array detection. A simulated serum matrix blank was repeatedly analyzed for determination of LOB parametrically by using the observed blank distribution as well as nonparametrically by using ranks. The LOD was determined by combining information regarding the LOB with data from repeated analysis of standard reference materials (SRMs), diluted to low levels; from LOB to 2-3 times LOB. The LOQ was determined experimentally by plotting the observed relative standard deviation (RSD) of SRM replicates compared with the concentration, where the LOQ is the concentration at an RSD of 20%. Experimental approaches and example statistical procedures are given for determination of LOB, LOD, and LOQ. These quantities are reported for each measured analyte. For many analyses, there is considerable information available below the LOQ. Epidemiologic studies must understand the nature of these detection limits and how they have been estimated for appropriate treatment of affected data.
Yang, Qiong; Tofler, Geoffrey H; Cupples, L Adrienne; Larson, Martin G; Feng, DaLi; Lindpaintner, Klaus; Levy, Daniel; D'Agostino, Ralph B; O'Donnell, Christopher J
2003-04-15
Circulating levels of fibrinogen are associated with atherosclerosis and predict future coronary heart disease and stroke. Levels of fibrinogen are correlated among family members, suggesting a heritable component. Variants of the beta-fibrinogen gene subunit on 4q28 are associated with fibrinogen levels but explain only a small proportion of the total genetic variability. It remains unknown what role, if any, is played by other genetic variants in the inter-individual variability in levels of fibrinogen in the general population. We conducted a 10-cM spaced genome-wide scan using 402 original cohort subjects and 1193 offspring subjects from 330 extended families of the Framingham Heart Study. Heritability and linkage analyses were carried out using variance component methods. Regression analyses were performed to adjust for traditional risk factors and HindIII beta-148 genotypes. The total heritability was estimated as 0.24. The highest and second highest LOD scores of linkage were found on chromosomes 2 (LOD=1.5 at 243 cM) and 10 (LOD=2.4 at 87 cM) using only offspring subjects in the analysis, and on chromosomes 2 (LOD=2.1 at 242 cM) and 10(LOD=1.4 at 86 cM), 17 (LOD=1.4 at 96 cM) and 20 (LOD=1.4 at 80 cM) using both original cohort and offspring. These results suggest that there may be influential genetic regions on these chromosomes. While no linkage with genome-wide significance was detected, further research to confirm our findings is warranted.
A Miniaturized Linear Wire Ion Trap with Electron Ionization and Single Photon Ionization Sources
NASA Astrophysics Data System (ADS)
Wu, Qinghao; Tian, Yuan; Li, Ailin; Andrews, Derek; Hawkins, Aaron R.; Austin, Daniel E.
2017-05-01
A linear wire ion trap (LWIT) with both electron ionization (EI) and single photon ionization (SPI) sources was built. The SPI was provided by a vacuum ultraviolet (VUV) lamp with the ability to softly ionize organic compounds. The VUV lamp was driven by a pulse amplifier, which was controlled by a pulse generator, to avoid the detection of photons during ion detection. Sample gas was introduced through a leak valve, and the pressure in the system is shown to affect the signal-to-noise ratio and resolving power. Under optimized conditions, the limit of detection (LOD) for benzene was 80 ppbv using SPI, better than the LOD using EI (137 ppbv). System performance was demonstrated by distinguishing compounds in different classes from gasoline.
Biosensor-based microRNA detection: techniques, design, performance, and challenges.
Johnson, Blake N; Mutharasan, Raj
2014-04-07
The current state of biosensor-based techniques for amplification-free microRNA (miRNA) detection is critically reviewed. Comparison with non-sensor and amplification-based molecular techniques (MTs), such as polymerase-based methods, is made in terms of transduction mechanism, associated protocol, and sensitivity. Challenges associated with miRNA hybridization thermodynamics which affect assay selectivity and amplification bias are briefly discussed. Electrochemical, electromechanical, and optical classes of miRNA biosensors are reviewed in terms of transduction mechanism, limit of detection (LOD), time-to-results (TTR), multiplexing potential, and measurement robustness. Current trends suggest that biosensor-based techniques (BTs) for miRNA assay will complement MTs due to the advantages of amplification-free detection, LOD being femtomolar (fM)-attomolar (aM), short TTR, multiplexing capability, and minimal sample preparation requirement. Areas of future importance in miRNA BT development are presented which include focus on achieving high measurement confidence and multiplexing capabilities.
Nanomolar colorimetric quantitative detection of Fe3 + and PPi with high selectivity
NASA Astrophysics Data System (ADS)
Li, Zhanxian; Li, Haixia; Shi, Caixia; Yu, Mingming; Wei, Liuhe; Ni, Zhonghai
2016-04-01
A novel rhodamine and 8-hydroxyquinoline-based derivative was synthesized, which is shown to act as a colorimetric chemosensor for Fe3 + in aqueous solution with high selectivity over various environmentally and biologically relevant metal ions and anions with a distinct color change from colorless to pink in very fast response time (< 1 min). Fe3 + can be detected quantitatively in the concentration range from 6.7 to 16 μM and the detection limit (LOD) on UV-vis response of the sensor can be as low as 15 nM. The 'in situ' prepared Fe3 + complex (1 ṡ Fe) showed high selectivity toward PPi against many common anions, and sensitivity (the LOD can be as low as 71 nM). In addition, both the chemosensor and the 'in situ' prepared Fe3 + complex are reusable for the detection of Fe3 + and PPi respectively.
NASA Astrophysics Data System (ADS)
Zhang, Yang; Xu, Jie; Cao, Derang; Li, Qiang; Zhao, Guoxia; Sun, Nian X.; Li, Shandong
2018-05-01
In the broad research of the GMR bio-sensing technology, it is vital to explore appropriate magnetic labels and its influences on the detection signal. In this work, four kinds of ferrite particles of γ-Fe2O3, CoFe2O4, NiFe2O4 and NiZnFe2O4 were prepared through calcining the Dimethyl Formamide (DMF) solution of the transition metal nitrates [Fe(NO3)3 and X(NO3)2, X = Co, Ni, Zn] to study the effect of magnetic properties on detection signals using a DC in-plane measuring method. It was revealed that for four particles, the output voltage differences |ΔV| between with and without magnetic particles exhibit log-linear functions of the particles concentrations x in the range from 0.1 to 10 ng/mL. A very low limitation of detection (LOD) of 0.1 ng/mL for all the samples was obtained, which is two orders smaller than that in the previous work. Moreover, the change of output voltage difference at the LOD (|ΔVlim|) is proportional to the magnetization at bias field (bias magnetization, Mbias), which indicates that larger Mbias leads to a lower LOD. This work provides a useful guidance in selecting or preparing magnetic labels to enhance the sensitivity of GMR biosensors.
Clancy, Eoin; Cormican, Martin; Boo, Teck Wee; Cunney, Robert
2018-01-01
Bacterial meningitis infection is a leading global health concern for which rapid and accurate diagnosis is essential to reduce associated morbidity and mortality. Loop-mediated isothermal amplification (LAMP) offers an effective low-cost diagnostic approach; however, multiplex LAMP is difficult to achieve, limiting its application. We have developed novel real-time multiplex LAMP technology, TEC-LAMP, using Tth endonuclease IV and a unique LAMP primer/probe. This study evaluates the analytical specificity, limit of detection (LOD) and clinical application of an internally controlled multiplex TEC-LAMP assay for detection of leading bacterial meningitis pathogens: Streptococcus pneumoniae, Neisseria meningitidis and Haemophilus influenzae. Analytical specificities were established by testing 168 bacterial strains, and LODs were determined using Probit analysis. The TEC-LAMP assay was 100% specific, with LODs for S. pneumoniae, N. meningitidis and H. influenzae of 39.5, 17.3 and 25.9 genome copies per reaction, respectively. Clinical performance was evaluated by testing 65 archived PCR-positive samples. Compared to singleplex real-time PCR, the multiplex TEC-LAMP assay demonstrated diagnostic sensitivity and specificity of 92.3% and 100%, respectively. This is the first report of a single-tube internally controlled multiplex LAMP assay for bacterial meningitis pathogen detection, and the first report of Tth endonuclease IV incorporation into nucleic acid amplification diagnostic technology. PMID:29425124
Higgins, Owen; Clancy, Eoin; Cormican, Martin; Boo, Teck Wee; Cunney, Robert; Smith, Terry J
2018-02-09
Bacterial meningitis infection is a leading global health concern for which rapid and accurate diagnosis is essential to reduce associated morbidity and mortality. Loop-mediated isothermal amplification (LAMP) offers an effective low-cost diagnostic approach; however, multiplex LAMP is difficult to achieve, limiting its application. We have developed novel real-time multiplex LAMP technology, TEC-LAMP, using Tth endonuclease IV and a unique LAMP primer/probe. This study evaluates the analytical specificity, limit of detection (LOD) and clinical application of an internally controlled multiplex TEC-LAMP assay for detection of leading bacterial meningitis pathogens: Streptococcus pneumoniae , Neisseria meningitidis and Haemophilus influenzae . Analytical specificities were established by testing 168 bacterial strains, and LODs were determined using Probit analysis. The TEC-LAMP assay was 100% specific, with LODs for S. pneumoniae , N. meningitidis and H. influenzae of 39.5, 17.3 and 25.9 genome copies per reaction, respectively. Clinical performance was evaluated by testing 65 archived PCR-positive samples. Compared to singleplex real-time PCR, the multiplex TEC-LAMP assay demonstrated diagnostic sensitivity and specificity of 92.3% and 100%, respectively. This is the first report of a single-tube internally controlled multiplex LAMP assay for bacterial meningitis pathogen detection, and the first report of Tth endonuclease IV incorporation into nucleic acid amplification diagnostic technology.
Weaver, Mitchell T; Lynch, Kyle B; Zhu, Zaifang; Chen, Huang; Lu, Joann J; Pu, Qiaosheng; Liu, Shaorong
2017-04-01
Laser-induced fluorescence (LIF) detectors for low-micrometer and sub-micrometer capillary on-column detection are not commercially available. In this paper, we describe in details how to construct a confocal LIF detector to address this issue. We characterize the detector by determining its limit of detection (LOD), linear dynamic range (LDR) and background signal drift; a very low LOD (~70 fluorescein molecules or 12 yoctomole fluorescein), a wide LDR (greater than 3 orders of magnitude) and a small background signal drift (~1.2-fold of the root mean square noise) are obtained. For detecting analytes inside a low-micrometer and sub-micrometer capillary, proper alignment is essential. We present a simple protocol to align the capillary with the optical system and use the position-lock capability of a translation stage to fix the capillary in position during the experiment. To demonstrate the feasibility of using this detector for narrow capillary systems, we build a 2-μm-i.d. capillary flow injection analysis (FIA) system using the newly developed LIF prototype as a detector and obtain an FIA LOD of 14 zeptomole fluorescein. We also separate a DNA ladder sample by bare narrow capillary - hydrodynamic chromatography and use the LIF prototype to monitor the resolved DNA fragments. We obtain not only well-resolved peaks but also the quantitative information of all DNA fragments. Copyright © 2016 Elsevier B.V. All rights reserved.
Huang, J; Vieland, V J
2001-01-01
It is well known that the asymptotic null distribution of the homogeneity lod score (LOD) does not depend on the genetic model specified in the analysis. When appropriately rescaled, the LOD is asymptotically distributed as 0.5 chi(2)(0) + 0.5 chi(2)(1), regardless of the assumed trait model. However, because locus heterogeneity is a common phenomenon, the heterogeneity lod score (HLOD), rather than the LOD itself, is often used in gene mapping studies. We show here that, in contrast with the LOD, the asymptotic null distribution of the HLOD does depend upon the genetic model assumed in the analysis. In affected sib pair (ASP) data, this distribution can be worked out explicitly as (0.5 - c)chi(2)(0) + 0.5chi(2)(1) + cchi(2)(2), where c depends on the assumed trait model. E.g., for a simple dominant model (HLOD/D), c is a function of the disease allele frequency p: for p = 0.01, c = 0.0006; while for p = 0.1, c = 0.059. For a simple recessive model (HLOD/R), c = 0.098 independently of p. This latter (recessive) distribution turns out to be the same as the asymptotic distribution of the MLS statistic under the possible triangle constraint, which is asymptotically equivalent to the HLOD/R. The null distribution of the HLOD/D is close to that of the LOD, because the weight c on the chi(2)(2) component is small. These results mean that the cutoff value for a test of size alpha will tend to be smaller for the HLOD/D than the HLOD/R. For example, the alpha = 0.0001 cutoff (on the lod scale) for the HLOD/D with p = 0.05 is 3.01, while for the LOD it is 3.00, and for the HLOD/R it is 3.27. For general pedigrees, explicit analytical expression of the null HLOD distribution does not appear possible, but it will still depend on the assumed genetic model. Copyright 2001 S. Karger AG, Basel
Selvaprakash, Karuppuchamy; Chen, Yu-Chie
2017-06-15
Ricin produced from the castor oil plant, Ricinus communis, is a well-known toxin. The toxin comprises A and B chains. Ricin A chain can cause toxicity by inhibiting protein synthesis, and ricin B can bind to the galactose ligand on the cell membrane of host cells. Inhalation or ingestion of ricin may even lead to death. Therefore, rapid and convenient sensing methods for detecting ricin in suspicious samples must be developed. In this study, we generated protein encapsulated gold nanoclusters (AuNCs@ew) with bright photoluminescence by using chicken egg white proteins as starting materials to react with aqueous tetrachloroaurate. The generated nanoclusters, which were mainly composed of chicken ovalbumin-encapsulated AuNCs, can recognize ricin B because of the presence of Galβ(1→4)GlcNAc ligands on chicken ovalbumin. The generated conjugates of AuNCs@ew and ricin B were heavy and readily settled down under centrifugation (13,000rpm, 60min). Thus, bright spots resulting from the conjugates at the bottom of the sample vials were easily visualized by the naked eye under ultraviolet light illumination. The limit of detection (LOD) was ~4.6µM. The LOD was reduced to ~400nM when fluorescence spectroscopy was used as the detection tool, while the LOD can be further improved to ~7.8nM when using matrix-assisted laser desorption/ionization mass spectrometry as the detection method. We also demonstrated the feasibility of using the proposed approach to selectively detect ricin B chain in complex samples. Copyright © 2016 Elsevier B.V. All rights reserved.
Garcés-Vega, Francisco; Marks, Bradley P
2014-08-01
In the last 20 years, the use of microbial reduction models has expanded significantly, including inactivation (linear and nonlinear), survival, and transfer models. However, a major constraint for model development is the impossibility to directly quantify the number of viable microorganisms below the limit of detection (LOD) for a given study. Different approaches have been used to manage this challenge, including ignoring negative plate counts, using statistical estimations, or applying data transformations. Our objective was to illustrate and quantify the effect of negative plate count data management approaches on parameter estimation for microbial reduction models. Because it is impossible to obtain accurate plate counts below the LOD, we performed simulated experiments to generate synthetic data for both log-linear and Weibull-type microbial reductions. We then applied five different, previously reported data management practices and fit log-linear and Weibull models to the resulting data. The results indicated a significant effect (α = 0.05) of the data management practices on the estimated model parameters and performance indicators. For example, when the negative plate counts were replaced by the LOD for log-linear data sets, the slope of the subsequent log-linear model was, on average, 22% smaller than for the original data, the resulting model underpredicted lethality by up to 2.0 log, and the Weibull model was erroneously selected as the most likely correct model for those data. The results demonstrate that it is important to explicitly report LODs and related data management protocols, which can significantly affect model results, interpretation, and utility. Ultimately, we recommend using only the positive plate counts to estimate model parameters for microbial reduction curves and avoiding any data value substitutions or transformations when managing negative plate counts to yield the most accurate model parameters.
Sandoval, Yader; Smith, Stephen W; Shah, Anoop S V; Anand, Atul; Chapman, Andrew R; Love, Sara A; Schulz, Karen; Cao, Jing; Mills, Nicholas L; Apple, Fred S
2017-01-01
Rapid rule-out strategies using high-sensitivity cardiac troponin assays are largely supported by studies performed outside the US in selected cohorts of patients with chest pain that are atypical of US practice, and focused exclusively on ruling out acute myocardial infarction (AMI), rather than acute myocardial injury, which is more common and associated with a poor prognosis. Prospective, observational study of consecutive patients presenting to emergency departments [derivation (n = 1647) and validation (n = 2198) cohorts], where high-sensitivity cardiac troponin I (hs-cTnI) was measured on clinical indication. The negative predictive value (NPV) and diagnostic sensitivity of an hs-cTnI concentration
Dong, Fengshou; Chen, Xiu; Xu, Jun; Liu, Xingang; Chen, Zenglong; Li, Yuanbo; Zhang, Hongjun; Zheng, Yongquan
2013-12-01
The chiral fungicide furametpyr is widely used in the rice field to control rice sheath blight; however, furametpyr enantiomers are treated as just one compound in traditional achiral analysis, which gives only partial information. An effective chiral analytical method was developed for the resolution and determination of the fungicide furametpyr enantiomers in rice, soil, and water samples. Furametpyr enantiomers were excellently separated and determined on a Chiralpak AD-H column with n-hexane/ethanol (90:10, v/v) as mobile phase at a flow rate of 0.8 mL min(-1) with UV detection at 220 nm. The resolution was up to 8.85. The first eluted enantiomer was (+)-furametpyr and the second eluted one was (-)-furametpyr. The effects of mobile-phase composition and column temperature on the enantioseparation were evaluated. The method was validated for linearity, repeatability, accuracy, limit of detection (LOD), and limit of quantification LOQ. LOD was 2.0 µg kg(-1) in water, 0.02 mg kg(-1) in soil, and 0.07 mg kg(-1) in rice with an LOQ of 6.7 µg kg(-1) in water, 0.07 mg kg(-1) in soil, and 0.23 mg kg(-1) in rice. The average recoveries of the pesticide in all matrices ranged from 73.1 to 101.8% for all fortification levels. The precision values associated with the analytical method, expressed as relative standard deviation (RSD) values, were below 14.0% in all matrices. The methodology was successfully applied for the enantioselective analysis of furametpyr enantiomers in real samples. © 2013 Wiley Periodicals, Inc.
Carlson, M; Thompson, R D
2001-01-01
A liquid chromatographic (LC) method was developed for the determination of allantoin, uric acid, and indoxyl sulfate in mammalian urine contaminated packaging material including paper bagging, corrugated cardboard, grayboard, and burlap bagging. The procedure involves solvent extraction and isolation of the 3 analytes by reversed-phase LC with ultraviolet detection at 225 nm for allantoin and 286 nm for uric acid and indoxyl sulfate. The composition of authentic mammalian urine such as mouse, rat, cat, dog, and human were also determined with regard to the 3 compounds of interest. A linear concentration range of 0.11-20.4, 0.02-10.0, and 0.04-30.0 microg/mL was obtained for allantoin, uric acid, and indoxyl sulfate, respectively. Limits of detection (LOD) and quantitation (LOQ) were 0.0104 and 0.0345 microg/mL for allantoin; 0.0018 and 0.0060 microg/mL for uric acid; and 0.0049 and 0.0165 microg/mL for indoxyl sulfate, respectively. Interday relative standard deviation values for a mixture of standard allantoin, uric acid, and indoxyl sulfate (n = 5) were 0.97, 0.80, and 0.94%, respectively. Analyte composition for 5 types of authentic mammalian urine varied from 0.19-6.88 mg/mL allantoin; 0.08-0.57 mg/mL uric acid; and 0.03-0.78 mg/mL indoxyl sulfate. Analyte content for 8 samples including 2 samples each for paper, cardboard, grayboard, and burlap bagging each contaminated with mouse or rat urine ranged from
Body, Richard; Burrows, Gillian; Carley, Simon; Cullen, Louise; Than, Martin; Jaffe, Allan S; Lewis, Philip S
2015-07-01
Initial reports suggest that concentrations of high-sensitivity cardiac troponin T (hs-cTnT) (Roche Diagnostics Elecsys(®)) below the limit of blank (LoB) (3 ng/L) or limit of detection (LoD) (5 ng/L) of the assay have almost 100% negative predictive value (NPV) for acute myocardial infarction (AMI), particularly among patients without electrocardiograph (ECG) evidence of ischemia. We aimed to prospectively validate those findings. We included adults presenting to the emergency department with suspected cardiac chest pain. Standard troponin T (cTnT) and hs-cTnT (both Roche Elecsys) were tested in samples drawn on arrival. The primary outcome was AMI, adjudicated by 2 investigators on the basis of clinical data and ≥12-h cTnT testing. We also evaluated diagnostic performance when AMI was readjudicated on the basis of hs-cTnT (≥12-h) concentrations. Of 463 patients included, 79 (17.1%) had AMI. Twenty-four patients (5.2%) had hs-cTnT concentrations below the LoB, although none had AMI. Ninety-six patients (20.7%) had hs-cTnT concentrations below the LoD, 1 of whom had AMI. Thus, diagnostic sensitivity was 98.7% (95% CI 87.5%-98.6%) and NPV was 99.0% (95% CI 94.3%-100.0%). Of the 17.3% (n = 80) patients with hs-cTnT below the LoD and no ECG ischemia, none had AMI. Thus, diagnostic sensitivity was 100.0% (95% CI 95.4%-100.0%) and NPV was 100.0% (95% CI 95.5%-100.0%). Sensitivity and NPV were maintained when AMI was readjudicated on the basis of hs-cTnT. Our findings confirm that patients with nonischemic ECG and undetectable hs-cTnT at presentation have a very low probability of AMI, although the proportion of patients affected was smaller than in previous research. © 2015 American Association for Clinical Chemistry.
Sex-specific genetic determinants for arterial stiffness in Dahl salt-sensitive hypertensive rats.
Decano, Julius L; Pasion, Khristine A; Black, Nicole; Giordano, Nicholas J; Herrera, Victoria L; Ruiz-Opazo, Nelson
2016-01-11
Arterial stiffness is an independent predictor of cardiovascular outcomes in hypertensive patients including myocardial infarction, fatal stroke, cerebral micro-bleeds which predicts cerebral hemorrhage in hypertensive patients, as well as progression to hypertension in non-hypertensive subjects. The association between arterial stiffness and various cardiovascular outcomes (coronary heart disease, stroke) remains after adjusting for age, sex, blood pressure, body mass index and other known predictors of cardiovascular disease, suggesting that arterial stiffness, measured via carotid-femoral pulse wave velocity, has a better predictive value than each of these factors. Recent evidence shows that arterial stiffening precedes the onset of high blood pressure; however their molecular genetic relationship (s) and sex-specific determinants remain uncertain. We investigated whether distinct or shared genetic determinants might underlie susceptibility to arterial stiffening in male and female Dahl salt-sensitive rats. Thus, we performed a genome-wide scan for quantitative trait loci (QTLs) affecting arterial stiffness in six-week old F2 (Dahl S x R)-intercross male and female rats characterized for abdominal aortic pulse wave velocity and aortic strain by high-resolution ultrasonography. We detected five highly significant QTLs affecting aortic stiffness: two interacting QTLs (AS-m1 on chromosome 4 and AS-m2 on chromosome16, LOD 8.8) in males and two distinct interacting QTLs (AS-f1 on chromosome 9 and AS-f2 on chromosome11, LOD 8.9) in females affecting pulse wave velocity. One QTL (AS-1 on chromosome 3, LOD 4.3) was found to influence aortic strain in a sex-independent manner. None of these arterial stiffness QTLs co-localized with previously reported blood pressure QTLs detected in equivalent genetic intercrosses. These data reveal sex-specific genetic determinants for aortic pulse wave velocity and suggest distinct polygenic susceptibility for arterial stiffness and salt-sensitive hypertension in Dahl rats based upon reported blood pressure QTLs in equivalent (Dahl S x R)-intercrosses.
Methods for detecting additional genes underlying Alzheimer disease
DOE Office of Scientific and Technical Information (OSTI.GOV)
Locke, P.A.; Haines, J.L.; Ter-Minassian, M.
1994-09-01
Alzheimer`s disease (AD) is a complex inherited disorder with proven genetic heterogeneity. To date, genes on chromosome 21 (APP) and 14 (not yet identified) are associated with early-onset familial AD, while the APOE gene on chromosome 19 is associated with both late onset familial and sporadic AD and early onset sporadic AD. Although these genes likely account for the majority of AD, many familial cases cannot be traced to any of these genes. From a set of 127 late-onset multiplex families screened for APOE, 43 (34%) families have at least one affected individual with no APOE-4 allele, suggesting an alternativemore » genetic etiology. Simulation studies indicated that additional loci could be identified through a genomic screen with a 10 cM sieve on a subset of 21 well documented, non-APOE-4 families. Given the uncertainties in the mode of inheritance, reliance on a single analytical method could result in a missed linkage. Therefore, we have developed a strategy of using multiple overlapping yet complementary methods to detect linkage. These include sib-pair analysis and affected-pedigree-member analysis, neither of which makes assumptions about mode of inheritance, and lod score analysis (using two predefined genetic models). In order for a marker to qualify for follow-up, it must fit at least two of three criteria. These are nominal P values of 0.05 or less for the non-parametric methods, and/or a lod score greater than 1.0. Adjacent markers each fulfilling a single criterion also warrant follow-up. To date, we have screened 61 markers on chromosomes 1, 2, 3, 18, 19, 21, and 22. One marker, D2S163, generated a lod score of 1.06 ({theta} = 0.15) and an APMT statistic of 3.68 (P < 0.001). This region is currently being investigated in more detail. Updated results of this region plus additional screening data will be presented.« less
Hrvolová, Barbora; Martínez-Huélamo, Miriam; Colmán-Martínez, Mariel; Hurtado-Barroso, Sara; Lamuela-Raventós, Rosa Maria; Kalina, Jiří
2016-01-01
The concentration of carotenoids and fat-soluble vitamins in human plasma may play a significant role in numerous chronic diseases such as age-related macular degeneration and some types of cancer. Although these compounds are of utmost interest for human health, methods for their simultaneous determination are scarce. A new high pressure liquid chromatography (HPLC)-tandem mass spectrometry (MS/MS) method for the quantification of selected carotenoids and fat-soluble vitamins in human plasma was developed, validated, and then applied in a pilot dietary intervention study with healthy volunteers. In 50 min, 16 analytes were separated with an excellent resolution and suitable MS signal intensity. The proposed HPLC–MS/MS method led to improvements in the limits of detection (LOD) and quantification (LOQ) for all analyzed compounds compared to the most often used HPLC–DAD methods, in some cases being more than 100-fold lower. LOD values were between 0.001 and 0.422 µg/mL and LOQ values ranged from 0.003 to 1.406 µg/mL, according to the analyte. The accuracy, precision, and stability met with the acceptance criteria of the AOAC (Association of Official Analytical Chemists) International. According to these results, the described HPLC-MS/MS method is adequately sensitive, repeatable and suitable for the large-scale analysis of compounds in biological fluids. PMID:27754400
Hrvolová, Barbora; Martínez-Huélamo, Miriam; Colmán-Martínez, Mariel; Hurtado-Barroso, Sara; Lamuela-Raventós, Rosa Maria; Kalina, Jiří
2016-10-14
The concentration of carotenoids and fat-soluble vitamins in human plasma may play a significant role in numerous chronic diseases such as age-related macular degeneration and some types of cancer. Although these compounds are of utmost interest for human health, methods for their simultaneous determination are scarce. A new high pressure liquid chromatography (HPLC)-tandem mass spectrometry (MS/MS) method for the quantification of selected carotenoids and fat-soluble vitamins in human plasma was developed, validated, and then applied in a pilot dietary intervention study with healthy volunteers. In 50 min, 16 analytes were separated with an excellent resolution and suitable MS signal intensity. The proposed HPLC-MS/MS method led to improvements in the limits of detection (LOD) and quantification (LOQ) for all analyzed compounds compared to the most often used HPLC-DAD methods, in some cases being more than 100-fold lower. LOD values were between 0.001 and 0.422 µg/mL and LOQ values ranged from 0.003 to 1.406 µg/mL, according to the analyte. The accuracy, precision, and stability met with the acceptance criteria of the AOAC (Association of Official Analytical Chemists) International. According to these results, the described HPLC-MS/MS method is adequately sensitive, repeatable and suitable for the large-scale analysis of compounds in biological fluids.
NASA Astrophysics Data System (ADS)
Hwang, Joonki; Lee, Sangyeop; Choo, Jaebum
2016-06-01
A novel surface-enhanced Raman scattering (SERS)-based lateral flow immunoassay (LFA) biosensor was developed to resolve problems associated with conventional LFA strips (e.g., limits in quantitative analysis and low sensitivity). In our SERS-based biosensor, Raman reporter-labeled hollow gold nanospheres (HGNs) were used as SERS detection probes instead of gold nanoparticles. With the proposed SERS-based LFA strip, the presence of a target antigen can be identified through a colour change in the test zone. Furthermore, highly sensitive quantitative evaluation is possible by measuring SERS signals from the test zone. To verify the feasibility of the SERS-based LFA strip platform, an immunoassay of staphylococcal enterotoxin B (SEB) was performed as a model reaction. The limit of detection (LOD) for SEB, as determined with the SERS-based LFA strip, was estimated to be 0.001 ng mL-1. This value is approximately three orders of magnitude more sensitive than that achieved with the corresponding ELISA-based method. The proposed SERS-based LFA strip sensor shows significant potential for the rapid and sensitive detection of target markers in a simplified manner.A novel surface-enhanced Raman scattering (SERS)-based lateral flow immunoassay (LFA) biosensor was developed to resolve problems associated with conventional LFA strips (e.g., limits in quantitative analysis and low sensitivity). In our SERS-based biosensor, Raman reporter-labeled hollow gold nanospheres (HGNs) were used as SERS detection probes instead of gold nanoparticles. With the proposed SERS-based LFA strip, the presence of a target antigen can be identified through a colour change in the test zone. Furthermore, highly sensitive quantitative evaluation is possible by measuring SERS signals from the test zone. To verify the feasibility of the SERS-based LFA strip platform, an immunoassay of staphylococcal enterotoxin B (SEB) was performed as a model reaction. The limit of detection (LOD) for SEB, as determined with the SERS-based LFA strip, was estimated to be 0.001 ng mL-1. This value is approximately three orders of magnitude more sensitive than that achieved with the corresponding ELISA-based method. The proposed SERS-based LFA strip sensor shows significant potential for the rapid and sensitive detection of target markers in a simplified manner. Electronic supplementary information (ESI) available. See DOI: 10.1039/c5nr07243c
Guo, Jinchao; Yang, Litao; Liu, Xin; Guan, Xiaoyan; Jiang, Lingxi; Zhang, Dabing
2009-08-26
Genetically modified (GM) papaya (Carica papaya L.), Huanong No. 1, was approved for commercialization in Guangdong province, China in 2006, and the development of the Huanong No. 1 papaya detection method is necessary for implementing genetically modified organism (GMO) labeling regulations. In this study, we reported the characterization of the exogenous integration of GM Huanong No. 1 papaya by means of conventional polymerase chain reaction (PCR) and thermal asymmetric interlaced (TAIL)-PCR strategies. The results suggested that one intact copy of the initial construction was integrated in the papaya genome and which probably resulted in one deletion (38 bp in size) of the host genomic DNA. Also, one unintended insertion of a 92 bp truncated NptII fragment was observed at the 5' end of the exogenous insert. Furthermore, we revealed its 5' and 3' flanking sequences between the insert DNA and the papaya genomic DNA, and developed the event-specific qualitative and quantitative PCR assays for GM Huanong No. 1 papaya based on the 5' integration flanking sequence. The relative limit of detection (LOD) of the qualitative PCR assay was about 0.01% in 100 ng of total papaya genomic DNA, corresponding to about 25 copies of papaya haploid genome. In the quantitative PCR, the limits of detection and quantification (LOD and LOQ) were as low as 12.5 and 25 copies of papaya haploid genome, respectively. In practical sample quantification, the quantified biases between the test and true values of three samples ranged from 0.44% to 4.41%. Collectively, we proposed that all of these results are useful for the identification and quantification of Huanong No. 1 papaya and its derivates.
Fan, Ziyan; Keum, Young Soo; Li, Qing X; Shelver, Weilin L; Guo, Liang-Hong
2012-05-01
Indirect competitive immunoassays were developed on protein microarrays for the sensitive and simultaneous detection of multiple environmental chemicals in one sample. In this assay, a DNA/SYTOX Orange conjugate was employed as an antibody label to increase the fluorescence signal and sensitivity of the immunoassays. Epoxy-modified glass slides were selected as the substrate for the production of 4 × 4 coating antigen microarrays. With this signal-enhancing system, competition curves for 17β-estradiol (E2), benzo[a]pyrene (BaP) and 2,2',4,4'-tetrabromodiphenyl ether (BDE-47) were obtained individually on the protein microarray. The IC(50) and calculated limit of detection (LOD) are 0.32 μg L(-1) and 0.022 μg L(-1) for E2, 37.2 μg L(-1) and 24.5 μg L(-1) for BaP, and 31.6 μg L(-1) and 2.8 μg L(-1) for BDE-47, respectively. LOD of E2 is 14-fold lower than the value reported in a previous study using Cy3 labeled antibody (Du et al., Clin. Chem, 2005, 51, 368-375). The results of the microarray immunoassay were within 15% of chromatographic analysis for all three pollutants in spiked river water samples, thus verifying the immunoassay. Simultaneous detection of E2, BaP and BDE-47 in one sample was demonstrated. There was no cross-reaction in the immunoassay between these three environmental chemicals. These results suggest that microarray-based immunoassays with DNA/dye conjugate labels are useful tools for the rapid, sensitive, and high throughput screening of multiple environmental contaminants.
An, Jiwoo; Anderson, Jared L
2018-05-15
A double-confined polymeric ionic liquid (PIL) sorbent coating was fabricated for the determination of nine ultraviolet (UV) filters in sample solutions containing high salt content by direct immersion solid-phase microextraction (DI-SPME) coupled to high-performance liquid chromatography (HPLC). The IL monomer and crosslinker cations and anions, namely, 1-vinyl-3-decylimidazolium styrenesulfonate ([VImC 10 ][SS]) and 1,12-di(3-vinylbenzylimidazolium) dodecane distyrenesulfonate ([(VBIm) 2 C 12 ] 2[SS]), were co-polymerized to create a highly stable sorbent coating which allowed for up to 120 direct-immersion extractions in 25% NaCl (w/v) solution without a decrease in its extraction capability. Extraction and desorption parameters such as desorption solvent, agitation rate, extraction time, desorption solvent volume, and desorption time were evaluated and optimized. The analytical performance of the styrenesulfonate anion-based PIL fiber, PIL fiber containing chloride anions, and a commercially available polydimethylsiloxane/divinylbenzene (PDMS/DVB) fiber were compared. Coefficients of determination (R 2 ) for the styrenesulfonate anion-based PIL fiber ranged from 0.995 to 0.999 and the limits of detection (LODs) varied from 0.1 to 5 µg L -1 . The developed method was successfully applied in real water samples including tap, pool, and lake water, and acceptable relative recovery values were obtained. The lifetime of the PIL fiber containing chloride anions as well as the PDMS/DVB fiber were considerably shorter than the PIL fiber containing the styrenesulfonate anion, with both fibers showing a notable decrease in reproducibility and significant damage to the sorbent coating surface after 40 and 70 extractions, respectively. The R 2 values for the chloride anion containing PIL fiber were at or higher than 0.991 with LODs ranging from 0.5 to 5 µg L -1 . For the PDMS/DVB fiber, R 2 values ranged from 0.992 to 0.999 and LODs were found to be as low as 0.2 µg L -1 and as high as 5 µg L -1 . Copyright © 2018 Elsevier B.V. All rights reserved.
Fischer, David J.; Hulvey, Matthew K.; Regel, Anne R.; Lunte, Susan M.
2012-01-01
The fabrication and evaluation of different electrode materials and electrode alignments for microchip electrophoresis with electrochemical (EC) detection is described. The influences of electrode material, both metal and carbon-based, on sensitivity and limits of detection (LOD) were examined. In addition, the effects of working electrode alignment on analytical performance (in terms of peak shape, resolution, sensitivity, and LOD) were directly compared. Using dopamine (DA), norepinephrine (NE), and catechol (CAT) as test analytes, it was found that pyrolyzed photoresist electrodes with end-channel alignment yielded the lowest limit of detection (35 nM for DA). In addition to being easier to implement, end-channel alignment also offered better analytical performance than off-channel alignment for the detection of all three analytes. In-channel electrode alignment resulted in a 3.6-fold reduction in peak skew and reduced peak tailing by a factor of 2.1 for catechol in comparison to end-channel alignment. PMID:19802847
Zhang, Yi; Cui, Peipei; Zhang, Feng; Feng, Xiaoting; Wang, Yaling; Yang, Yongzhen; Liu, Xuguang
2016-05-15
Fluorescent nitrogen-doped carbon dots (NCDs) were synthesized by a facile, and low-cost one-step hydrothermal strategy using citric acid as carbon source and ammonia solution as nitrogen source for the first time. The obtained NCDs show stable blue fluorescence with a high quantum yield of 35.4%, along with the fluorescence lifetime of ca. 6.75 ns. Most importantly, Hg(2+) can completely quench the fluorescence of NCDs as a result of the formation of a non-fluorescent stable NCDs-Hg(2+) complex. Static fluorescence quenching towards Hg(2+) is proved by the Stern-Volmer equation, ultraviolet-visible absorption spectra, temperature dependent quenching and fluorescence lifetime measurements. Subsequently, the fluorescence of the NCDs-Hg(2+) system is completely recovered with the addition L-cysteine (L-Cys) owing to the dissociation of NCDs-Hg(2+) complex to form a more stable Hg(2+)-L-Cys complex by Hg(2+)-S bonding. Therefore, such NCDs can be used as an effective fluorescent "turn-off" probe for rapid, rather highly selective and sensitive detection of Hg(2+), with a limit of detection (LOD) as low as 1.48 nM and a linear detection range of 0-10 μM. Interestingly, NCDs-Hg(2+) system can be conveniently employed as a fluorescent "turn-on" sensor for highly selective and sensitive detection of L-Cys with a low LOD of 0.79 nM and a wide linear detection range of 0-50 μM. Further, the sensitivity of NCDs to Hg(2+) is preserved in tap water with a LOD of 1.65 nM and a linear detection range of 0-10 μM. Copyright © 2016 Elsevier B.V. All rights reserved.
Sex-specific Linkage Scans in Opioid Dependence
Yang, Bao-Zhu; Han, Shizhong; Kranzler, Henry R.; Palmer, Abraham A.; Gelernter, Joel
2017-01-01
Sex influences risk for opioid dependence (OD). We hypothesized that sex might interact with genetic loci that influence the risk for OD. Therefore we performed an analysis to identify sex-specific genomic susceptibility regions for OD using linkage. Over 6000 single nucleotide polymorphism (SNP) markers were genotyped for 1758 African- and European-American (AA and EA) individuals from 739 families, ascertained via affected sib-pairs with OD and/or cocaine dependence. Autosomewide non-parametric linkage scans, stratified by sex and population, were performed. We identified one significant linkage region, segregating with OD in EA men, at 71.1 cM on chromosome 4 (LOD=3.29; point-wise p=0.00005; empirical autosome-wide p=0.042), which significantly differed from the linkage signal at the same location in EA women (empirical p=0.002). Three suggestive linkage signals were identified at 181.3 cM on chromosome 7 (LOD=2.18), 104 cM on chromosome 11 (LOD=1.85), and 60.9 cM on chromosome 16 (LOD=1.93) in EA women. In AA men, four suggestive linkage signals were detected at 201.1 cM on chromosome 3 (LOD=2.32), 152.9 cM on chromosome 6 (LOD=1.86), 16.8 cM on chromosome 7 (LOD=1.95), and 36.1 cM on chromosome 17 (LOD=1.99). The significant region, mapping to 4q12-4q13.1, harbors several OD candidate genes with interconnected functionality, including VEGFR, CLOCK, PDCL2, NMU, NRSF, and IGFBP7. In conclusion, these results provide an evidence for the existence of sex-specific and population-specific differences in OD. Furthermore, these results provide positional information that will facilitate the use of targeted next-generation sequencing to search for genes that contribute to sex-specific differences in OD. PMID:27762075
Asensio-Ramos, M; Hernández-Borges, J; Borges-Miquel, T M; Rodríguez-Delgado, M A
2009-08-11
A new, simple and cost-effective method based on the use of multi-walled carbon nanotubes (MWCNTs) as solid-phase extraction stationary phases is proposed for the determination of a group of seven organophosphorus pesticides (i.e. ethoprophos, diazinon, chlorpyriphos-methyl, fenitrothion, malathion, chlorpyriphos and phosmet) and one thiadiazine (buprofezin) in different kinds of soil samples (forestal, ornamental and agricultural) using gas chromatography with nitrogen phosphorus detection. Soils were first ultrasound extracted with 10 mL 1:1 methanol/acetonitrile (v/v) and the evaporated extract redissolved in 20 mL water (pH 6.0) was passed through 100 mg of MWCNTs of 10-15 nm o.d., 2-6 nm i.d. and 0.1-10 microm length. Elution was carried out with 20 mL dichloromethane. The method was validated in terms of linearity, precision, recovery, accuracy and selectivity. Matrix-matched calibration was carried out for each type of soil since statistical differences between the calibration curves constructed in pure solvent and in the reconstituted soil extract were found for most of the pesticides under study. Recovery values of spiked samples ranged between 54 and 91% for the three types of soils (limits of detection (LODs) between 2.97 and 9.49 ngg(-1)), except for chlorpyrifos, chlorpyrifos-methyl and buprofezin which ranged between 12 and 54% (LODs between 3.14 and 72.4 ngg(-1)), which are the pesticides with the highest soil organic carbon sorption coefficient (K(OC)) values. Using a one-sample test (Student's t-test) with fortified samples at two concentration levels in each type of soil, no significant differences were observed between the real and the experimental values (accuracy percentages ranged between 87 and 117%). It is the first time that the adsorptive potential of MWCNTs for the extraction of organophosphorus pesticides from soils is investigated.
Anderson, Kim A.; Szelewski, Michael J.; Wilson, Glenn; Quimby, Bruce D.; Hoffman, Peter D.
2015-01-01
We describe modified gas chromatography electron-impact/triple-quadrupole mass spectrometry (GC–EI/MS/MS) utilizing a newly developed hydrogen-injected self-cleaning ion source and modified 9 mm extractor lens. This instrument, with optimized parameters, achieves quantitative separation of 62 polycyclic aromatic hydrocarbons (PAHs). Existing methods historically limited rigorous identification and quantification to a small subset, such as the 16 PAHs the US EPA has defined as priority pollutants. Without the critical source and extractor lens modifications, the off-the-shelf GC–EI/MS/MS system was unsuitable for complex PAH analysis. Separations were enhanced by increased gas flow, a complex GC temperature profile incorporating multiple isothermal periods, specific ramp rates, and a PAH-optimized column. Typical determinations with our refined GC–EI/MS/MS have a large linear range of 1–10,000 pg μl−1 and detection limits of <2 pg μl−1. Included in the 62 PAHs, multiple-reaction-monitoring (MRM) mode enabled GC-EI/MS/MS identification and quantitation of several constituents of the MW 302 PAHs isomers. Using calibration standards, values determined were within 5% of true values over many months. Standard curve r2 values were typically >0.998, exceptional for compounds which are archetypally difficult. With this method benzo[a]fluorene, benzo[b]fluorene, benzo[c]fluorene were fully separated as was benzo[b]fluoranthene, benzo[k]fluoranthene, and benzo[j]fluoranthene. Chrysene and triphenylene, were sufficiently separated to allow accurate quantitation. Mean limits of detection (LODs) across all PAHs were 1.02 ± 0.84 pg μl−1 with indeno[1,2,3-c,d] pyrene having the lowest LOD at 0.26 pg μl−1 and only two analytes above 2.0 pg μl−1; acenaphthalene (2.33 pg μl−1) and dibenzo[a,e]pyrene (6.44 pg μl−1). PMID:26454790
Tůma, Petr; Málková, Klára; Samcová, Eva; Stulík, Karel
2011-07-18
A capillary electrophoresis (CE) procedure with contactless conductivity detection (C(4)D) has been developed for monitoring of neutral mono- and disaccharides in drinks and foodstuffs. The separation of a mixture of seven neutral saccharides (glucose, fructose, galactose, mannose, ribose, sucrose and lactose) employed a quartz capillary, 5 μm i.d., with an effective length of 18.3 cm, and 75 mM NaOH (pH 12.8) as the background electrolyte (BGE). The limit of detection (LOD) values obtained lied within a range from 0.4 μmol L(-1) for lactose to 0.9 μmol L(-1) for ribose, with a separation time shorter than 140 s. The procedure was successfully applied to determinations of saccharides in fruit juices, Coca-Cola, milk, red and white wines, yoghurts, honey and a foodstuff additive. Copyright © 2011 Elsevier B.V. All rights reserved.
Pérez-Mitta, Gonzalo; Peinetti, Ana S; Cortez, M Lorena; Toimil-Molares, María Eugenia; Trautmann, Christina; Azzaroni, Omar
2018-05-09
Molecular design of biosensors based on enzymatic processes taking place in nanofluidic elements is receiving increasing attention by the scientific community. In this work, we describe the construction of novel ultrasensitive enzymatic nanopore biosensors employing "reactive signal amplifiers" as key elements coupled to the transduction mechanism. The proposed framework offers innovative design concepts not only to amplify the detected ionic signal and develop ultrasensitive nanopore-based sensors but also to construct nanofluidic diodes displaying specific chemo-reversible rectification properties. The integrated approach is demonstrated by electrostatically assembling poly(allylamine) on the anionic pore walls followed by the assembly of urease. We show that the cationic weak polyelectrolyte acts as a "reactive signal amplifier" in the presence of local pH changes induced by the enzymatic reaction. These bioinduced variations in proton concentration ultimately alter the protonation degree of the polyamine resulting in amplifiable, controlled, and reproducible changes in the surface charge of the pore walls, and consequently on the generated ionic signals. The "iontronic" response of the as-obtained devices is fully reversible, and nanopores are reused and assayed with different urea concentrations, thus ensuring reliable design. The limit of detection (LOD) was 1 nM. To the best of our knowledge, this value is the lowest LOD reported to date for enzymatic urea detection. In this context, we envision that this approach based on the use of "reactive signal amplifiers" into solid-state nanochannels will provide new alternatives for the molecular design of highly sensitive nanopore biosensors as well as (bio)chemically addressable nanofluidic elements.
Henn, Raphael; Kirchler, Christian G; Grossgut, Maria-Elisabeth; Huck, Christian W
2017-05-01
This study compared three commercially available spectrometers - whereas two of them were miniaturized - in terms of prediction ability of melamine in milk powder (infant formula). Therefore all spectra were split into calibration- and validation-set using Kennard Stone and Duplex algorithm in comparison. For each instrument the three best performing PLSR models were constructed using SNV and Savitzky Golay derivatives. The best RMSEP values were 0.28g/100g, 0.33g/100g and 0.27g/100g for the NIRFlex N-500, the microPHAZIR and the microNIR2200 respectively. Furthermore the multivariate LOD interval [LOD min , LOD max ] was calculated for all the PLSR models unveiling significant differences among the spectrometers showing values of 0.20g/100g - 0.27g/100g, 0.28g/100g - 0.54g/100g and 0.44g/100g - 1.01g/100g for the NIRFlex N-500, the microPHAZIR and the microNIR2200 respectively. To assess the robustness of all models, artificial introduction of white noise, baseline shift, multiplicative effect, spectral shrink and stretch, stray light and spectral shift were applied. Monitoring the RMSEP as function of the perturbation gave indication of robustness of the models and helped to compare the performances of the spectrometers. Not taking the additional information from the LOD calculations into account one could falsely assume that all the spectrometers perform equally well which is not the case when the multivariate evaluation and robustness data were considered. Copyright © 2017 Elsevier B.V. All rights reserved.
Xiao, Ge; Saunders, David; Jones, Robert L.; Caldwell, Kathleen L.
2016-01-01
Quantification of 241Am in urine at low levels is important for assessment of individuals’ or populations’ accidental, environmental, or terrorism-related internal contamination, but no convenient, precise method has been established to rapidly determine these low levels. Here we report a new analytical method to measure 241Am as developed and validated at the Centers for Disease Control and Prevention (CDC) by means of the selective retention of Am from urine directly on DGA resin, followed by SF-ICP-MS detection. The method provides rapid results with a Limit of Detection (LOD) of 0.22 pg/L (0.028 Bq/L), which is lower than 1/3 of the C/P CDG for 241Am at 5 days post-exposure. The results obtained by this method closely agree with CDC values as measured by Liquid Scintillation Counting, and with National Institute of Standards Technology (NIST) Certified Reference Materials (CRM) target values. PMID:27375308
Xiao, Ge; Saunders, David; Jones, Robert L; Caldwell, Kathleen L
2016-07-01
Quantification of 241 Am in urine at low levels is important for assessment of individuals' or populations' accidental, environmental, or terrorism-related internal contamination, but no convenient, precise method has been established to rapidly determine these low levels. Here we report a new analytical method to measure 241 Am as developed and validated at the Centers for Disease Control and Prevention (CDC) by means of the selective retention of Am from urine directly on DGA resin, followed by SF-ICP-MS detection. The method provides rapid results with a Limit of Detection (LOD) of 0.22 pg/L (0.028 Bq/L), which is lower than 1/3 of the C/P CDG for 241 Am at 5 days post-exposure. The results obtained by this method closely agree with CDC values as measured by Liquid Scintillation Counting, and with National Institute of Standards Technology (NIST) Certified Reference Materials (CRM) target values.
Dual fluorescence/contactless conductivity detection for microfluidic chip.
Liu, Cui; Mo, Yun-yan; Chen, Zuan-guang; Li, Xiang; Li, Ou-lian; Zhou, Xie
2008-07-28
A new dual detection system for microchip is reported. Both fluorescence detector (FD) and contactless conductivity detector (CCD) were combined together and integrated on a microfluidic chip. They shared a common detection position and responded simultaneously. A blue light-emitting diode was used as excitation source and a small planar photodiode was used to collect the emitted fluorescence in fluorescence detection, which made the device more compact and portable. The coupling of the fluorescence and contactless conductivity modes at the same position of a single separation channel enhanced the detection characterization of sample and offered simultaneous detection information of both fluorescent and charged specimen. The detection conditions of the system were optimized. K(+), Na(+), fluorescein sodium, fluorescein isothiocyanate (FITC) and FITC-labeled amino acids were used to evaluate the performance of the dual detection system. The limits of detection (LOD) of FD for fluorescein Na(+), FITC, FITC-labeled arginine (Arg), glycine (Gly) and phenylalanine (Phe) were 0.02micromolL(-1), 0.05micromolL(-1), 0.16micromolL(-1), 0.15micromolL(-1), 0.12micromolL(-1) respectively, and the limits of detection (LOD) of CCD achieved 0.58micromolL(-1) and 0.39micromolL(-1) for K(+) and Na(+) respectively.
Maruti, Astrid; Durán-Guerrero, Enrique; Barroso, Carmelo G; Castro, Remedios
2018-05-25
A novel extraction technique is proposed in which the Multiple Headspace Extraction (MHE) approach is used in conjunction with Headspace Sorptive Extraction (HSSE) and Gas Chromatography-Mass Spectrometry (GC-MS) detection. The extraction method was developed to determine volatile compounds in macroalgae. Optimization of the extraction parameters was carried out using design of experiments to identify factors that affect the extraction: extraction time, temperature, twister length and amount of sample. The results of the optimization led to an extraction of 2 g of sample using a 20 mm Twister ® at 66 °C for 180 min. The progression constants (β) were calculated for 43 volatile compounds, 29 of which could be quantified using the method. Linearity was attained with a determination coefficient higher than 0.99 for all studied compounds. Inter-day and inter-twister precisions ranged from 0.22% to 19.01% and from 0.69% to 14.76% respectively, and values below 10% were obtained for the majority of compounds. LOD and LOQ values ranged from the values obtained for diethyl succinate (0.012 μg/L and 0.088 μg/L, respectively) and those obtained for dimethyl sulfide (5.544 μg/L and 40.286 μg/L, respectively). However, for the majority of compounds values obtained were below 1 μg/L (LOD) and 5 μg/L (LOQ). Compounds such as ethyl acetate, hexanal, heptadecane, 2-hexenal, 6-methyl-5-hepten-2-one, dimethyl sulfide, benzyl alcohol, beta ionone, or beta cyclocitral, among others were correctly determined in three species of macroalgae: Ulva sp., Gracillaria sp. and Enteromorpha sp. Copyright © 2018 Elsevier B.V. All rights reserved.
Kaushik, Sharbani; Goswami, Pranab
2018-06-06
The biosensing application of microbial fuel cell (MFC) is hampered by its long response time, poor selectivity, and technical difficulty in developing portable devices. Herein, a novel signal form for rapid detection of ethanol was generated in a photosynthetic MFC (PMFC). First, a dual chambered (100 mL each) PMFC was fabricated by using cyanobacteria-based anode and abiotic cathode, and its performance was examined for detection of alcohols. A graphene-based nanobiocomposite matrix was layered over graphite anode to support cyanobacterial biofilm growth and to facilitate electron transfer. Injection of alcohols into the anodic chamber caused a transient potential burst of the PMFC within 60 s (load 1000 Ω), and the magnitude of potential could be correlated to the ethanol concentrations in the range 0.001-20% with a limit of detection (LOD) of 0.13% ( R 2 = 0.96). The device exhibited higher selectivity toward ethanol than methanol as discerned from the corresponding cell-alcohol interaction constant ( K i ) of 780 and 1250 mM. The concept was then translated to a paper-based PMFC (p-PMFC) (size ∼20 cm 2 ) wherein, the cells were merely immobilized over the anode. The device with a shelf life of ∼3 months detected ethanol within 10 s with a dynamic range of 0.005-10% and LOD of 0.02% ( R 2 = 0.99). The fast response time was attributed to the higher wettability of ethanol on the immobilized cell surface as validated by the contact angle data. Alcohols degraded the cell membrane on the order of ethanol > methanol, enhanced the redox current of the membrane-bound electron carrier proteins, and pushed the anodic band gap toward more negative value. The consequence was the potential burst, the magnitude of which was correlated to the ethanol concentrations. This novel approach has a great application potential for selective, sensitive, rapid, and portable detection of ethanol.
Improved quality control of [18F]fluoromethylcholine.
Nader, Michael; Reindl, Dietmar; Eichinger, Reinhard; Beheshti, Mohsen; Langsteger, Werner
2011-11-01
With respect to the broad application of [(18)F-methyl]fluorocholine (FCH), there is a need for a safe, but also efficient and convenient way for routine quality control of FCH. Therefore, a GC- method should be developed and validated which allows the simultaneous quantitation of all chemical impurities and residual solvents such as acetonitrile, ethanol, dibromomethane and N,N-dimethylaminoethanol. Analytical GC has been performed with a GC-capillary column Optima 1701 (50 m×0.32 mm), and a pre-column deactivated capillary column phenyl-Sil (10 m×0.32) in line with a flame ionization detector (FID) was used. The validation includes the following tests: specificity, range, accuracy, linearity, precision, limit of detection (LOD) and limit of quantitation (LOQ) of all listed substances. The described GC method has been successfully used for the quantitation of the listed chemical impurities. The specificity of the GC separation has been proven by demonstrating that the appearing peaks are completely separated from each other and that a resolution R≥1.5 for the separation of the peaks could be achieved. The specified range confirmed that the analytical procedure provides an acceptable degree of linearity, accuracy and precision. For each substance, a range from 2% to 120% of the specification limit could be demonstrated. The corresponding LOD values were determined and were much lower than the specification limits. An efficient and convenient GC method for the quality control of FCH has been developed and validated which meets all acceptance criteria in terms of linearity, specificity, precision, accuracy, LOD and LOQ. Copyright © 2011 Elsevier Inc. All rights reserved.
Interval mapping of high growth (hg), a major locus that increases weight gain in mice
DOE Office of Scientific and Technical Information (OSTI.GOV)
Horvat, S.; Medrano, J.F.
1995-04-01
The high growth locus (hg) causes a major increase in weight gain and body size in mice. As a first step to map-based cloning of hg, we developed a genetic map of the hg-containing region using interval mapping of 403 F{sub 2} from a C57BL/6J-hghg x CAST/EiJ cross. The maximum likelihood position of hg was at the chromosome 10 marker D10Mit41 (LOD = 24.8) in the F{sub 2} females and 1.5 cM distal to D10Mit41 (LOD = 9.56) in the F{sub 2} males with corresponding LOD 2 support intervals of 3.7 and 5.4 cM, respectively. The peak LOD scores weremore » significantly higher than the estimated empirical threshold LOD values. The localization of hg by interval mapping was supported by a test cross of F{sub 2} mice recombinant between the LOD 2 support interval and the flanking marker. The interval mapping and test-cross indicate that hg is not allelic with candidate genes Igf1 or decorin (Dcn), a gene that was mapped close to hg in this study. The hg inheritance was recessive in females, although we could not reject recessive or additive inheritance in males. Possible causes for sex differences in peak LOD scores and for the distortion of transmission ratios observed in F{sub 2} males are discussed. The genetic map of the hg region will facilitate further fine mapping and cloning of hg, and allow searches for a homologous quantitative trait locus affecting growth in humans and domestic animals. 48 refs., 3 figs., 3 tabs.« less
Liu, Rui; Yue, Yingying; Hou, Zhenghua; Yuan, Yonggui; Wang, Qiao
2018-08-01
Abnormal functional connectivity (FC) in the default mode network (DMN) plays an important role in late-onset depression (LOD) patients. In this study, the risk predictors of LOD based on anterior and posterior DMN are explored. A total of 27 LOD patients and 40 healthy controls (HC) underwent resting-state functional magnetic resonance imaging and cognitive assessments. Firstly, FCs within DMN sub-networks were determined by placing seeds in the ventral medial prefrontal cortex (vmPFC) and posterior cingulate cortex (PCC). Secondly, multivariable logistic regression was used to identify risk factors for LOD patients. Finally, correlation analysis was performed to investigate the relationship between risk factors and the cognitive value. Multivariable logistic regression showed that the FCs between the vmPFC and right middle temporal gyrus (MTG) (vmPFC-MTG_R), FCs between the vmPFC and left precuneus (PCu), and FCs between the PCC and left PCu (PCC-PCu_L) were the risk factors for LOD. Furthermore, FCs of the vmPFC-MTG_R and PCC-PCu_L correlated with processing speed (R = 0.35, P = 0.002; R = 0.32, P = 0.009), and FCs of the vmPFC-MTG_R correlated with semantic memory (R = 0.41, P = 0.001). The study was a cross-sectional study. The results may be potentially biased because of a small sample. In this study, we confirmed that LOD patients mainly present cognitive deficits in processing speed and semantic memory. Moreover, our findings further suggested that FCs within DMN sub-networks associated with cognitions were risk factors, which may be used for the prediction of LOD. Copyright © 2018 Elsevier B.V. All rights reserved.
The Little Ice Age was 1.0-1.5 °C cooler than current warm period according to LOD and NAO
NASA Astrophysics Data System (ADS)
Mazzarella, Adriano; Scafetta, Nicola
2018-02-01
We study the yearly values of the length of day (LOD, 1623-2016) and its link to the zonal index (ZI, 1873-2003), the Northern Atlantic oscillation index (NAO, 1659-2000) and the global sea surface temperature (SST, 1850-2016). LOD is herein assumed to be mostly the result of the overall circulations occurring within the ocean-atmospheric system. We find that LOD is negatively correlated with the global SST and with both the integral function of ZI and NAO, which are labeled as IZI and INAO. A first result is that LOD must be driven by a climatic change induced by an external (e.g. solar/astronomical) forcing since internal variability alone would have likely induced a positive correlation among the same variables because of the conservation of the Earth's angular momentum. A second result is that the high correlation among the variables implies that the LOD and INAO records can be adopted as global proxies to reconstruct past climate change. Tentative global SST reconstructions since the seventeenth century suggest that around 1700, that is during the coolest period of the Little Ice Age (LIA), SST could have been about 1.0-1.5 °C cooler than the 1950-1980 period. This estimated LIA cooling is greater than what some multiproxy global climate reconstructions suggested, but it is in good agreement with other more recent climate reconstructions including those based on borehole temperature data.
NASA Astrophysics Data System (ADS)
Bilge, Gonca; Sezer, Banu; Boyaci, Ismail Hakki; Eseller, Kemal Efe; Berberoglu, Halil
2018-07-01
Liquid analysis by using LIBS is a complicated process due to difficulties encountered during the collection of light and formation of plasma in liquid. To avoid these, some applications are performed such as aerosol formation and transforming liquid into solid state. However, performance of LIBS in liquid samples still remains a challenging issue. In this study, performance evaluation of LIBS and parameter optimizations in liquid and solid phase samples were performed. For this purpose, milk was chosen as model sample; milk powder was used as solid sample, and milk was used as liquid sample in the experiments. Different experimental setups have been constructed for each sampling technique, and optimizations were performed to determine suitable parameters such as delay time, laser energy, repetition rate and speed of rotary table for solid sampling technique, and flow rate of carrier gas for liquid sampling technique. Target element was determined as Ca, which is a critically important element in milk for determining its nutritional value and Ca addition. In optimum parameters, limit of detection (LOD), limit of quantification (LOQ) and relative standard deviation (RSD) values were calculated as 0.11%, 0.36% and 8.29% respectively for milk powders samples; while LOD, LOQ and RSD values were calculated as 0.24%, 0.81%, and 10.93% respectively for milk samples. It can be said that LIBS is an applicable method in both liquid and solid samples with suitable systems and parameters. However, liquid analysis requires much more developed systems for more accurate results.
Identification in Marinomonas mediterranea of a novel quinoprotein with glycine oxidase activity.
Campillo-Brocal, Jonatan Cristian; Lucas-Elio, Patricia; Sanchez-Amat, Antonio
2013-08-01
A novel enzyme with lysine-epsilon oxidase activity was previously described in the marine bacterium Marinomonas mediterranea. This enzyme differs from other l-amino acid oxidases in not being a flavoprotein but containing a quinone cofactor. It is encoded by an operon with two genes lodA and lodB. The first one codes for the oxidase, while the second one encodes a protein required for the expression of the former. Genome sequencing of M. mediterranea has revealed that it contains two additional operons encoding proteins with sequence similarity to LodA. In this study, it is shown that the product of one of such genes, Marme_1655, encodes a protein with glycine oxidase activity. This activity shows important differences in terms of substrate range and sensitivity to inhibitors to other glycine oxidases previously described which are flavoproteins synthesized by Bacillus. The results presented in this study indicate that the products of the genes with different degrees of similarity to lodA detected in bacterial genomes could constitute a reservoir of different oxidases. © 2013 The Authors. Microbiology Open published by John Wiley & Sons Ltd.
Comparison of empirical strategies to maximize GENEHUNTER lod scores.
Chen, C H; Finch, S J; Mendell, N R; Gordon, D
1999-01-01
We compare four strategies for finding the settings of genetic parameters that maximize the lod scores reported in GENEHUNTER 1.2. The four strategies are iterated complete factorial designs, iterated orthogonal Latin hypercubes, evolutionary operation, and numerical optimization. The genetic parameters that are set are the phenocopy rate, penetrance, and disease allele frequency; both recessive and dominant models are considered. We selected the optimization of a recessive model on the Collaborative Study on the Genetics of Alcoholism (COGA) data of chromosome 1 for complete analysis. Convergence to a setting producing a local maximum required the evaluation of over 100 settings (for a time budget of 800 minutes on a Pentium II 300 MHz PC). Two notable local maxima were detected, suggesting the need for a more extensive search before claiming that a global maximum had been found. The orthogonal Latin hypercube design was the best strategy for finding areas that produced high lod scores with small numbers of evaluations. Numerical optimization starting from a region producing high lod scores was the strategy that found the highest maximum observed.
Hu, Yaxi; Lu, Xiaonan
2016-05-01
An innovative "one-step" sensor conjugating molecularly imprinted polymers and surface enhanced Raman spectroscopic-active substrate (MIPs-SERS) was investigated for simultaneous extraction and determination of melamine in tap water and milk. This sensor was fabricated by integrating silver nanoparticles (AgNPs) with MIPs synthesized by bulk polymerization of melamine (template), methacrylic acid (functional monomer), ethylene glycol dimethacrylate (cross-linking agent), and 2,2'-azobisisobutyronitrile (initiator). Static and kinetic adsorption tests validated the specific affinity of MIPs-AgNPs to melamine and the rapid adsorption equilibration rate. Principal component analysis segregated SERS spectral features of tap water and milk samples with different melamine concentrations. Partial least squares regression models correlated melamine concentrations in tap water and skim milk with SERS spectral features. The limit of detection (LOD) and limit of quantification (LOQ) of melamine in tap water were determined as 0.0019 and 0.0064 mmol/L, while the LOD and LOQ were 0.0165 and 0.055 mmol/L for the determination of melamine in skim milk. However, this sensor is not ideal to quantify melamine in tap water and skim milk. By conjugating MIPs with SERS-active substrate (that is, AgNPs), reproducibility of SERS spectral features was increased, resulting in more accurate detection. The time required to determine melamine in tap water and milk were 6 and 25 min, respectively. The low LOD, LOQ, and rapid detection confirm the potential of applying this sensor for accurate and high-throughput detection of melamine in tap water and milk. © 2016 Institute of Food Technologists®
Ndiaye, Amadou L.; Delile, Sébastien; Brunet, Jérôme; Varenne, Christelle; Pauly, Alain
2016-01-01
Here, we report on the use of electrochemical methods for the detection of volatiles fatty acids (VFAs), namely acetic acid. We used tetra-tert-butyl phthalocyanine (PcH2-tBu) as the sensing material and investigated its electroanalytical properties by means of cyclic voltammetry (CV) and square wave voltammetry (SWV). To realize the electrochemical sensing system, the PcH2-tBu has been dropcast-deposited on carbon (C) orgold (Au)screen-printed electrodes (SPEs) and characterized by cyclic voltammetry and scanning electron microscopy (SEM). The SEM analysis reveals that the PcH2-tBu forms mainly aggregates on the SPEs. The modified electrodes are used for the detection of acetic acid and present a linear current increase when the acetic acid concentration increases. The Cmodified electrode presents a limit of detection (LOD) of 25.77 mM in the range of 100 mM–400 mM, while the Aumodified electrode presents an LOD averaging 40.89 mM in the range of 50 mM–300 mM. When the experiment is realized in a buffered condition, theCmodified electrode presents a lower LOD, which averagesthe 7.76 mM. A pronounced signal decay attributed to an electrode alteration is observed in the case of the gold electrode. This electrode alteration severely affects the coating stability. This alteration is less perceptible in the case of the carbon electrode. PMID:27598214
Smith, Jerome P; Sammons, Deborah L; Robertson, Shirley A; Pretty, Jack; Debord, D Gayle; Connor, Thomas H; Snawder, John
2015-01-01
Objectives Contamination of workplace surfaces by antineoplastic drugs presents an exposure risk for healthcare workers. Traditional instrumental methods to detect contamination such as liquid chromatography-tandem mass spectrometry (LC-MS/MS) are sensitive and accurate but expensive. Since immunochemical methods may be cheaper and faster than instrumental methods, we wanted to explore their use for routine drug residue detection for preventing worker exposure. Methods In this study we examined the feasibility of using fluorescence covalent microbead immunosorbent assay (FCMIA) for simultaneous detection and semi-quantitative measurement of three antineoplastic drugs (5-fluorouracil, paclitaxel, and doxorubicin). The concentration ranges for the assay were 0–1000 ng/ml for 5-fluorouracil, 0–100 ng/ml for paclitaxel, and 0–2 ng/ml for doxorubicin. The surface sampling technique involved wiping a loaded surface with a swab wetted with wash buffer, extracting the swab in storage/blocking buffer, and measuring drugs in the extract using FCMIA. Results There was no significant cross reactivity between these drugs at the ranges studied indicated by a lack of response in the assay to cross analytes. The limit of detection (LOD) for 5-fluorouracil on the surface studied was 0.93 ng/cm2 with a limit of quantitation (LOQ) of 2.8 ng/cm2, the LOD for paclitaxel was 0.57 ng/cm2 with an LOQ of 2.06 ng/cm2, and the LOD for doxorubicin was 0.0036 ng/cm2 with an LOQ of 0.013 ng/cm2. Conclusion The use of FCMIA with a simple sampling technique has potential for low cost simultaneous detection and semi-quantitative measurement of surface contamination from multiple antineoplastic drugs. PMID:25293722
Frederiksen, Hanne; Nielsen, Ole; Skakkebaek, Niels E; Juul, Anders; Andersson, Anna-Maria
2017-03-01
Experimental studies indicate that some chemicals with UV blocking properties (known as UV filters) can act as endocrine disruptors. UV filters are used in sunscreens and other cosmetic- and personal care products, as well as in other consumer products such as food packaging, clothing and furniture textiles to protect the products against UV radiation. Here we present the urinary excretion of suspected endocrine active UV filters in Danish children and adolescents recruited from the general population. The content of benzophenone (BP), benzophenone-1 (BP-1), benzophenone-2 (BP-2), benzophenone-3 (BP-3), 5-chloro-2- hydroxybenzophenone (BP-7), 4-hydroxybenzophenone (4-HBP), 4-methyl-benzophenone (4-MBP), 3-(4- methylbenzylidene)-camphor (4-MBC) and 3-benzylidene camphor (3-BC) were monitored in 24h urine and two consecutive first morning samples from 129 healthy Danish children and adolescents (6-21 yrs). All 387 samples were collected during the autumn (Nov. 2007) and were analyzed by a new on-line TurboFlow-LC-MS/MS method developed for simultaneous biomonitoring of these nine UV filters in urine. BP-3 and BP-1 were detected in more than 80% of the 24h samples and were significantly correlated (R 2 =0.815). BP, 4-HBP and BP-2 were found in 43, 15 and 5% of the samples, respectively. The median (range) concentrations of the UV-filters in 24-h urine were as follows: BP-3, 0.92 (LOD-115); BP-1, 0.54 (LOD-44.6); BP,
Zhang, Shan; Zhao, Shuai; Wang, Sai; Liu, Jiahui; Dong, Yiyang
2018-05-09
Lateral flow immunochromatographic strips based on colorants of aptamer-functionalized nanogold particles weredeveloped for the detection of micropollutants aflatoxin B1 (AFB1) and chloramphenicol (CAP). The lateral flow immunochromatographic strip was based on a competitive reaction of thiolated-aptamer between micropollutants and bio-DNA probe-streptavidin as capture material immobilized at the test line. General crucial parameters that might influence the sensitivity have been systematically investigated. To test the effectiveness and applicability of the optimized conditions, two structurally unrelated micropollutants, that is, AFB1 and CAP, were chosen for detection. In the present study, lateral flow immunochromatographic strips for AFB1 and CAP analysis by combining the high selectivity and affinity of aptamers with the unique optical properties of nanogold in municipal water samples were reported for the first time. With the optimized conditions, the immunochromatographic strip showed a visual LOD of 10 ppb and a quantitative LOD of 1.05 ppb using an immunochromatographic reader for AFB1 detection and a quantitative LOD of 63.4 ppb using an immunochromatographic reader for CAP detection. Furthermore, the sensitive strip provided a good linear detection range of approximately 0-50 ppm for AFB1 detection and a wider liner detection range of approximately 0-160 ppm for CAP detection. Moreover, the immunochromatographic strip provided recovery rates for water samples of 90-110% in the AFB1 analysis and 84-108% in the CAP analysis. The results demonstrated that the immunochromatographic strip has excellent potential for wide applicability and verified that the strip methods for the optimized conditions are applicable to a variety of micropollutants. The lateral flow immunochromatographic strip could be used as a simple, rapid, and efficient screening tool for rapid on-site detection of a variety of micropollutants.
MRI biosensor for lead detection based on the DNAzyme-induced catalytic reaction.
Xu, Liguang; Yin, Honghong; Ma, Wei; Wang, Libing; Kuang, Hua; Xu, Chuanlai
2013-11-21
A MRI biosensor for sensitive and specific detection of lead ions (Pb(2+)) was developed based on DNAzyme-induced cleavage of magnetic nanoparticles (MNPs). A low limit of detection (LOD) of 0.05 ng mL(-1) was obtained. This biosensor has the potential to serve as a general platform for the detection of heavy metal ions.
NASA Astrophysics Data System (ADS)
Toma, Mana; Tawa, Keiko
2018-03-01
A bioinspired polydopamine (PDA) coating is a good candidate for the rapid and cheap chemical modification of biosensor surfaces. Herein, we report the effect of PDA thickness on the detection sensitivity of a fluorescence biosensor utilizing surface plasmon-enhanced fluorescence. The thickness of PDA films was tuned by the incubation time of the dopamine solution and varied from 1 to 17 nm. The detection sensitivity was evaluated as the limit of detection (LOD) of a fluorescently labelled target analyte by a model immunoassay. The LOD was determined to be 1.6 pM for the thickest PDA film and was improved to 1.0 pM by reducing the thickness to the range from 1 to 5 nm, corresponding to the incubation time of 10 to 60 min. The experimental results indicate that the PDA coating is suitable for the surface functionalization of biosensors in mass production as it does not require precise control of the incubation time.
Casella, Innocenzo G; Pierri, Marianna; Contursi, Michela
2006-02-24
The electrochemical behaviour of the polycrystalline platinum electrode towards the oxidation/reduction of short-chain unsaturated aliphatic molecules such as acrylamide and acrylic acid was investigated in acidic solutions. Analytes were separated by reverse phase liquid chromatographic and quantified using a pulsed amperometric detection. A new two-step waveform, is introduced for detection of acrylamide and acrylic acid. Detection limits (LOD) of 20 nM (1. 4 microg/kg) and 45 nM (3.2 microg/kg) were determined in water solutions containing acrylamide and acrylic acid, respectively. Compared to the classical three-step waveform, the proposed two-step waveform shows favourable analytical performance in terms of LOD, linear range, precision and improved long-term reproducibility. The proposed analytical method combined with clean-up procedure accomplished by Carrez clearing reagent and subsequent extraction with a strong cation exchanger cartridges (SPE), was successfully used for the quantification of low concentrations of acrylamide in foodstuffs such as coffee and potato fries.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wahyuni, Wulan Tri, E-mail: wulantriws@gmail.com; Department of Chemistry, FMIPA, Universitas Indonesia, Kampus UI Depok; Ivandini, Tribidasari A.
Biomolecule modified magnetic beads has been widely used in separation and sensing process. This study used streptavidin modified magnetic beads to immobilize biotin modified zanamivir. Biotin-streptavidin affinity facilitates immobilization of zanamivir on magnetic beads. Then interaction of zanamivir and neuraminidase was adopted as basic for enzyme detection. Detection of neuraminidase was performed at gold modified BDD using cyclic voltammetry technique. The measurement was carried out based on alteration of electrochemical signals of working electrode as neuraminidase response. The result showed that zanamivir was successfully immobilized on magnetic beads. The optimum amount of magnetic beads for zanamivir immobilization was 120 ug.more » Linear responses of neuraminidase were detected in concentration range of 0-15 mU. Detection limit (LOD) of measurement was 2.32 mU (R2 = 0.959) with precision as % RSD of 1.41%. Measurement of neuraminidase on magnetic beads could be also performed in the presence of mucin matrix. The linearity range was 0-8 mU with LOD of 0.64 mU (R2 = 0.950) and % RSD of 7.25%.« less
Health-hazard evaluation report HETA 91-158-2161, Immaculate Heart of Mary Church, Cincinnati, Ohio
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cook, C.K.
1991-11-01
In response to a request from a representative of the Immaculate Heart of Mary Church (SIC-8661), an investigation was made of indoor air quality in the church office. Particular attention was directed toward laser printer and photocopier emissions. Employees had complained of headaches, dizziness, confusion, nausea, eye irritation, and dry nose and throat. Day shift employees performed general office duties, often using a photocopier and a laser printer. Real time ozone (10028156) concentrations ranged from below the limit of detection (LOD) to 0.05 parts per million (ppm) in the breathing zone, all below the NIOSH limit for short term exposuremore » of 0.10ppm. Ozone concentrations as high as 0.56ppm were detected at the laser printer exhaust. Carbon-dioxide (124389) concentrations ranged from 400 to 850ppm. Respirable dust concentrations ranged from below the LOD to 90 micrograms per cubic meter. Carbon-monoxide (630080) levels were not above the LOD of 5ppm. No volatile organic carbons were detected. Temperature and relative humidity levels were within the guidelines. Some of the symptoms were consistent with ozone exposure. The author concludes that efforts should be made to reduce ozone exposures. The author recommends relocating the laser printer, providing additional outside air to the building, and checking for possible overloading or inefficiency in the ozone filter in the printer.« less
Pectin characterisation using size exclusion chromatography: A comparison of ELS and RI detection.
Muñoz-Almagro, Nerea; Rico-Rodriguez, Fabián; Villamiel, Mar; Montilla, Antonia
2018-06-30
A high-performance size-exclusion chromatography (HPSEC) method coupled to Evaporative Light Scattering (ELS) and Refractive Index (RI) detectors were evaluated and compared for the molecular mass (Mw) estimation of pectin in a wide range (0.342-805 kDa). Instrumental parameters of the ELSD were optimised by Response Surface Methodology (RSM) being 73 °C the evaporator temperature and 0.9 mL/min the air flow rate. The linear range for the ELSD concentration response was wider (10-2250 mg/L) and better (R 2 = 0.985) than RID (10-1500 mg/L; R 2 = 0.875). The limits of detection (LOD) and quantitation (LOQ) for all pullulans hardly changed in ELSD (LOD: 1.22-1.99 mg/L; LOQ: 4.07-6.63 mg/L); however, RID showed huge variations (LOD: 0.49-10.41 mg/L; LOQ: 1.64-34.70 mg/L), which increased with the Mw. In general, responses of both detectors were similar for the Mw estimation, although pectin characterisation with HPSEC-ELSD exhibited better results in the lowest Mw compounds. Copyright © 2018 Elsevier Ltd. All rights reserved.
Barkley, Ruth Ann; Brown, Andrew C; Hanis, Craig L; Kardia, Sharon L; Turner, Stephen T; Boerwinkle, Eric
2003-07-01
The distribution of plasma lipoprotein[a] (Lp[a]) concentrations, a risk factor for cardiovascular disease, varies greatly among racial groups, with African Americans having values that are shifted toward higher levels than those of whites. The underlying cause of this heterogeneity is unknown, but a role for "trans-acting" factors has been hypothesized. This study used genetic linkage analysis to localize genetic factors influencing Lp[a] levels in African Americans that were absent in other populations; linkage results were analyzed separately in non-Hispanic whites, Hispanic whites, and African Americans. As expected, all three samples showed highly significant linkage at the approximate location of the lysophosphatidic acid locus. The white populations also independently had regions of significant linkage on chromosome 19 (LOD 3.80) and suggestive linkage on chromosomes 12 (LOD 1.60), 14 (LOD 2.56), and 19 (LOD 2.52). No linkage evidence was found to support the hypothesis of another single gene with large effects specifically segregating in African Americans that may account for their elevated Lp[a] levels.
Datlow, Mitchell D; Gray, Kelly M; Watts, Adriel; Diercks, Deborah B; Mumma, Bryn E
2017-12-01
When screening for acute myocardial infarction (AMI), troponin levels below the 99th percentile, including those below the limit of detection (LOD), are considered normal. We hypothesized that a low-risk HEART score (0-3) or ACS Pretest Probability Assessment <2% plus a single troponin below the LOD would rule out both AMI and 30-day major adverse cardiac events (MACE). We studied all patients who presented to a single academic emergency department and received a troponin I (Siemens Ultra Troponin I) from September 1, 2013, to November 13, 2013 (n=888). Demographic and clinical data were abstracted from the electronic medical record. Primary outcome was a final encounter diagnosis of myocardial infarction. Secondary outcome was 30-day MACE, defined as composite of myocardial infarction, revascularization, or death from a cardiac or uncertain etiology. Sensitivities of low-risk HEART score and ACS Pretest Probability <2% alone were 98% (95% confidence interval [CI], 89%-100%) and 96% (95% CI, 86%-100%) for AMI and 94% (95% CI, 86%-98%) and 95% (95% CI, 88%-99%), respectively, for 30-day MACE. When combined with troponin below the LOD, sensitivity for AMI was 100% (95% CI, 93%-100%; difference 2%; 95% CI, -2% to 6%) for low-risk HEART Score and 100% (95% CI, 93%-100%; difference 4%; 95% CI, -1.5% to 10%) for ACS Pretest Probability <2%. When combined with troponin below the LOD, sensitivity for 30-day MACE was 100% (95% CI, 95%-100%; difference 6%; 95% CI, 1%-12%) for low-risk HEART Score and 100% (95% CI, 95%-100%; difference 5%; 95% CI, 0.2%-10%) for ACS Pretest Probability <2%. Addition of a single troponin below the LOD to these scores improves sensitivity for 30-day MACE.
Park, Jong Eun; Kim, Ji Youn; Yun, Sun Ae; Lee, Myoung Keun; Huh, Hee Jae; Kim, Jong Won; Ki, Chang Seok
2016-11-01
Standardized cytomegalovirus (CMV) DNA quantification is important for managing CMV disease. We evaluated the performance of the Real-Q CMV Quantification Kit (Real-Q assay; BioSewoom, Korea) using whole blood (WB), with nucleic acid extraction using MagNA Pure 96 (Roche Diagnostics, Germany). Real-time PCR was performed on two platforms: the 7500 Fast real-time PCR (7500 Fast; Applied Biosystems, USA) and CFX96 real-time PCR detection (CFX96; Bio-Rad, USA) systems. The WHO international standard, diluted with CMV-negative WB, was used to validate the analytical performance. We used 90 WB clinical samples for comparison with the artus CMV RG PCR kit (artus assay; Qiagen, Germany). Limits of detections (LODs) in 7500 Fast and CFX96 were 367 and 479 IU/mL, respectively. The assay was linear from the LOD to 10⁶ IU/mL (R² ≥0.9886). The conversion factors from copies to IU in 7500 Fast and CFX96 were 0.95 and 1.06, respectively. Compared with the artus assay, for values <1,000 copies/mL, 100% of the samples had a variation <0.7 log₁₀ copies/mL; >1,000 copies/mL, 73.3% and 80.6% of samples in 7500 Fast and CFX96, respectively, had <0.5 log₁₀ copies/mL. The Real-Q assay is useful for quantifying CMV in WB with the two real-time PCR platforms.
Gallagher, Carla J; Gordon, Candace J; Langefeld, Carl D; Mychaleckyj, Josyf C; Freedman, Barry I; Rich, Stephen S; Bowden, Donald W; Sale, Michèle M
2006-01-01
African Americans (AA) are at increased risk for developing type 2 diabetes mellitus (T2DM) relative to European Americans. We previously detected linkage of T2DM to 6q24-q27 (LOD 2.26) at 163.5 cM, closest to marker D6S1035, in a genome-wide scan of AA families. The mu-opioid receptor gene (OPRM1) is located within the LOD-1 support interval of this linkage peak. OPRM1 is an attractive positional candidate gene for T2DM susceptibility since agonists of OPRM1 affect glucose-induced insulin release and OPRM1 knockout mice have a more rapid induction of insulin resistance than wild-type. Twenty-two SNPs in this gene, at an average spacing of 3.9 kb, were genotyped in 380 AA T2DM cases and 276 AA controls. In single SNP association analyses, rs648007 demonstrated significant evidence of association with T2DM (P=0.013). Four blocks of high linkage disequilibrium were detected across the OPRM1 gene. Association analyses of haplotypes in each of these blocks revealed two haplotype blocks with significant overall P values (P=0.007 and 0.046). Significant, but rare, risk and protective haplotypes were identified as driving these associations with T2DM (P=0.034-0.047). These associations suggest that the OPRM1 gene plays a role in T2DM susceptibility in African Americans.
Pyschik, Marcelina; Klein-Hitpaß, Marcel; Girod, Sabrina; Winter, Martin; Nowak, Sascha
2017-02-01
In this study, an optimized method using capillary electrophoresis (CE) with a direct contactless conductivity detector (C 4 D) for a new application field is presented for the quantification of fluoride in common used lithium ion battery (LIB) electrolyte using LiPF 6 in organic carbonate solvents and in ionic liquids (ILs) after contacted to Li metal. The method development for finding the right buffer and the suitable CE conditions for the quantification of fluoride was investigated. The results of the concentration of fluoride in different LIB electrolyte samples were compared to the results from the ion-selective electrode (ISE). The relative standard deviations (RSDs) and recovery rates for fluoride were obtained with a very high accuracy in both methods. The results of the fluoride concentration in the LIB electrolytes were in very good agreement for both methods. In addition, the limit of detection (LOD) and limit of quantification (LOQ) values were determined for the CE method. The CE method has been applied also for the quantification of fluoride in ILs. In the fresh IL sample, the concentration of fluoride was under the LOD. Another sample of the IL mixed with Li metal has been investigated as well. It was possible to quantify the fluoride concentration in this sample. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Zhang, Yaping; Yang, Jun; Shi, Ronghua; Su, Qingde; Yao, Li; Li, Panpan
2011-07-01
A method was developed to determine eight acetanilide herbicides from cereal crops based on accelerated solvent extraction (ASE) and solid-phase extraction (SPE) followed by gas chromatography-electron capture detector (GC-ECD) analysis. During the ASE process, the effect of four parameters (temperature, static time, static cycles and solvent) on the extraction efficiency was considered and compared with shake-flask extraction method. After extraction with ASE, four SPE tubes (graphitic carbon black/primary secondary amine (GCB/PSA), GCB, Florisil and alumina-N) were assayed for comparison to obtain the best clean-up efficiency. The results show that GCB/PSA cartridge gave the best recoveries and cleanest chromatograms. The analytical process was validated by the analysis of spiked blank samples. Performance characteristics such as linearity, limit of detection (LOD), limit of quantitation (LOQ), precision and recovery were studied. At 0.05 mg/kg spiked level, recoveries and precision values for rice, wheat and maize were 82.3-115.8 and 1.1-13.6%, respectively. For all the herbicides, LOD and LOQ ranged from 0.8 to 1.7 μg/kg and from 2.4 to 5.3 μg/kg, respectively. The proposed analytical methodology was applied for the analysis of the targets in samples; only three herbicides, propyzamid, metolachlor and diflufenican, were detected in two samples. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
NASA Astrophysics Data System (ADS)
Chen, Xiaochun; Yu, Shaoming; Yang, Liang; Wang, Jianping; Jiang, Changlong
2016-07-01
The instant and on-site detection of trace aqueous fluoride ions is still a challenge for environmental monitoring and protection. This work demonstrates a new analytical method and its utility of a paper sensor for visual detection of F- on the basis of the fluorescence resonance energy transfer (FRET) between photoluminescent graphene oxide (GO) and silver nanoparticles (AgNPs) through the formation of cyclic esters between phenylborinic acid and diol. The fluorescence of GO was quenched by the AgNPs, and trace F- can recover the fluorescence of the quenched photoluminescent GO. The increase in fluorescence intensity is proportional to the concentration of F- in the range of 0.05-0.55 nM, along with a limit of detection (LOD) as low as 9.07 pM. Following the sensing mechanism, a paper-based sensor for the visual detection of aqueous F- has been successfully developed. The paper sensor showed high sensitivity for aqueous F-, and the LOD could reach as low as 0.1 μM as observed by the naked eye. The very simple and effective strategy reported here could be extended to the visual detection of a wide range of analytes in the environment by the construction of highly efficient FRET nanoprobes.The instant and on-site detection of trace aqueous fluoride ions is still a challenge for environmental monitoring and protection. This work demonstrates a new analytical method and its utility of a paper sensor for visual detection of F- on the basis of the fluorescence resonance energy transfer (FRET) between photoluminescent graphene oxide (GO) and silver nanoparticles (AgNPs) through the formation of cyclic esters between phenylborinic acid and diol. The fluorescence of GO was quenched by the AgNPs, and trace F- can recover the fluorescence of the quenched photoluminescent GO. The increase in fluorescence intensity is proportional to the concentration of F- in the range of 0.05-0.55 nM, along with a limit of detection (LOD) as low as 9.07 pM. Following the sensing mechanism, a paper-based sensor for the visual detection of aqueous F- has been successfully developed. The paper sensor showed high sensitivity for aqueous F-, and the LOD could reach as low as 0.1 μM as observed by the naked eye. The very simple and effective strategy reported here could be extended to the visual detection of a wide range of analytes in the environment by the construction of highly efficient FRET nanoprobes. Electronic supplementary information (ESI) available. See DOI: 10.1039/c6nr02878k
Jiang, Keren; Wang, Yinan; Thakur, Garima; Kotsuchibashi, Yohei; Naicker, Selvaraj; Narain, Ravin; Thundat, Thomas
2017-05-10
A conjugated polymer interface consisting of an oxaborole containing polymer and a glycopolymer was used for achieving very high selectivity in dopamine (DA) detection. The optimum binding affinity between the polymers promotes the selectivity to DA through a displacement mechanism while remaining unaffected by other structurally related analogs and saccharide derivatives. Real-time detection of DA with very high selectivity and sensitivity has been demonstrated by immobilizing the polymer conjugates on surface plasmon resonance (SPR) and microcantilever (MCL) sensor platforms. Using the conjugated polymer sensing layer, the SPR biosensor was capable of detecting DA in the concentration range of 1 × 10 -9 to 1 × 10 -4 mol L -1 , whereas the MCL sensor showed a limit of detection (LOD) of 5 × 10 -11 mol L -1 . We find that the sensing mechanism is based on DA-induced reversible swelling of the conjugated polymer layer and this allows regeneration and reuse of the sensor multiple times. Also, we conclude that SPR is a suitable sensor platform for DA in-line detection at clinical level considering the detection time and stability, whereas MCL can achieve a much lower LOD.
Distributed gas sensing with optical fibre photothermal interferometry.
Lin, Yuechuan; Liu, Fei; He, Xiangge; Jin, Wei; Zhang, Min; Yang, Fan; Ho, Hoi Lut; Tan, Yanzhen; Gu, Lijuan
2017-12-11
We report the first distributed optical fibre trace-gas detection system based on photothermal interferometry (PTI) in a hollow-core photonic bandgap fibre (HC-PBF). Absorption of a modulated pump propagating in the gas-filled HC-PBF generates distributed phase modulation along the fibre, which is detected by a dual-pulse heterodyne phase-sensitive optical time-domain reflectometry (OTDR) system. Quasi-distributed sensing experiment with two 28-meter-long HC-PBF sensing sections connected by single-mode transmission fibres demonstrated a limit of detection (LOD) of ∼10 ppb acetylene with a pump power level of 55 mW and an effective noise bandwidth (ENBW) of 0.01 Hz, corresponding to a normalized detection limit of 5.5ppb⋅W/Hz. Distributed sensing experiment over a 200-meter-long sensing cable made of serially connected HC-PBFs demonstrated a LOD of ∼ 5 ppm with 62.5 mW peak pump power and 11.8 Hz ENBW, or a normalized detection limit of 312ppb⋅W/Hz. The spatial resolution of the current distributed detection system is limited to ∼ 30 m, but it is possible to reduce down to 1 meter or smaller by optimizing the phase detection system.
An extension of the Maximum Lod Score method to X-linked loci.
Cordell, H J; Kawaguchi, Y; Todd, J A; Farrall, M
1995-10-01
The Maximum Lod Score method for affected relative-pair analysis, introduced by Risch, is a powerful method for detecting linkage between an autosomal marker locus and disease. In order to use the method to detect linkage to markers on the X-chromosome, some modification is necessary. Here we extend the method to be applicable to X-chromosomal data, and derive genetic restrictions on the haplotype-sharing probabilities analogous to the 'possible triangle' restrictions described by Holmans for the autosomal case. Size criteria are derived using asymptotic theory and simulation, and the power is calculated for a number of possible underlying models. The method is applied to data from 284 type 1 diabetic families and evidence is found for the presence of one or more diabetogenic loci on the X-chromosome.
Jang, Hyun-June; Lee, Taein; Song, Jian; Russell, Luisa; Li, Hui; Dailey, Jennifer; Searson, Peter C; Katz, Howard E
2018-05-16
A field-effect transistor-based cortisol sensor was demonstrated in physiological conditions. An antibody-embedded polymer on the remote gate was proposed to overcome the Debye length issue (λ D ). The sensing membrane was made by linking poly(styrene- co-methacrylic acid) (PSMA) with anticortisol before coating the modified polymer on the remote gate. The embedded receptor in the polymer showed sensitivity from 10 fg/mL to 10 ng/mL for cortisol and a limit of detection (LOD) of 1 pg/mL in 1× PBS where λ D is 0.2 nm. A LOD of 1 ng/mL was shown in lightly buffered artificial sweat. Finally, a sandwich ELISA confirmed the antibody binding activity of antibody-embedded PSMA.
Modulation of the SSTA decadal variation on ENSO events and relationships of SSTA With LOD,SOI, etc
NASA Astrophysics Data System (ADS)
Liao, D. C.; Zhou, Y. H.; Liao, X. H.
2007-01-01
Interannual and decadal components of the length of day (LOD), Southern Oscillation Index (SOI) and Sea Surface Temperature anomaly (SSTA) in Nino regions are extracted by band-pass filtering, and used for research of the modulation of the SSTA on the ENSO events. Results show that besides the interannual components, the decadal components in SSTA have strong impacts on monitoring and representing of the ENSO events. When the ENSO events are strong, the modulation of the decadal components of the SSTA tends to prolong the life-time of the events and enlarge the extreme anomalies of the SST, while the ENSO events, which are so weak that they can not be detected by the interannual components of the SSTA, can also be detected with the help of the modulation of the SSTA decadal components. The study further draws attention to the relationships of the SSTA interannual and decadal components with those of LOD, SOI, both of the sea level pressure anomalies (SLPA) and the trade wind anomalies (TWA) in tropic Pacific, and also with those of the axial components of the atmospheric angular momentum (AAM) and oceanic angular momentum (OAM). Results of the squared coherence and coherent phases among them reveal close connections with the SSTA and almost all of the parameters mentioned above on the interannual time scales, while on the decadal time scale significant connections are among the SSTA and SOI, SLPA, TWA, ?3w and ?3w+v as well, and slight weaker connections between the SSTA and LOD, ?3pib and ?3bp
Hutton, Laura A; O'Neil, Glen D; Read, Tania L; Ayres, Zoë J; Newton, Mark E; Macpherson, Julie V
2014-05-06
The development of a novel analytical technique, electrochemical X-ray fluorescence (EC-XRF), is described and applied to the quantitative detection of heavy metals in solution, achieving sub-ppb limits of detection (LOD). In EC-XRF, electrochemical preconcentration of a species of interest onto the target electrode is achieved here by cathodic electrodeposition. Unambiguous elemental identification and quantification of metal concentration is then made using XRF. This simple electrochemical preconcentration step improves the LOD of energy dispersive XRF by over 4 orders of magnitude (for similar sample preparation time scales). Large area free-standing boron doped diamond grown using microwave plasma chemical vapor deposition techniques is found to be ideal as the electrode material for both electrodeposition and XRF due to its wide solvent window, transparency to the XRF beam, and ability to be produced in mechanically robust freestanding thin film form. During electrodeposition it is possible to vary both the deposition potential (Edep) and deposition time (tdep). For the metals Cu(2+) and Pb(2+) the highest detection sensitivities were found for Edep = -1.75 V and tdep (=) 4000 s with LODs of 0.05 and 0.04 ppb achieved, respectively. In mixed Cu(2+)/Pb(2+) solutions, EC-XRF shows that Cu(2+) deposition is unimpeded by Pb(2+), across a broad concentration range, but this is only true for Pb(2+) when both metals are present at low concentrations (10 nM), boding well for trace level measurements. In a dual mixed metal solution, EC-XRF can also be employed to either selectively deposit the metal which has the most positive formal reduction potential, E(0), or exhaustively deplete it from solution, enabling uninhibited detection of the metal with the more negative E(0).
Molecularly imprinted polymers as selective adsorbents for ambient plasma mass spectrometry.
Cegłowski, Michał; Smoluch, Marek; Reszke, Edward; Silberring, Jerzy; Schroeder, Grzegorz
2017-05-01
The application of molecularly imprinted polymers (MIPs) as molecular scavengers for ambient plasma ionization mass spectrometry has been reported for the first time. MIPs were synthesized using methacrylic acid as functional monomer; nicotine, propyphenazone, or methylparaben as templates; ethylene glycol dimethacrylate as a cross-linker; and 2,2'-azobisisobutyronitrile as polymerization initiator. To perform ambient plasma ionization experiments, a setup consisting of the heated crucible, a flowing atmospheric-pressure afterglow (FAPA) plasma ion source, and a quadrupole ion trap mass spectrometer has been used. The heated crucible with programmable temperature allows for desorption of the analytes from MIPs structure which results in their direct introduction into the ion stream. Limits of detection, linearity of the proposed analytical procedure, and selectivities have been determined for three analytes: nicotine, propyphenazone, and methylparaben. The analytes used were chosen from various classes of organic compounds to show the feasibility of the analytical procedure. The limits of detections (LODs) were 10 nM, 10, and 0.5 μM for nicotine, propyphenazone, and methylparaben, respectively. In comparison with the measurements performed for the non-imprinted polymers, the values of LODs were improved for at least one order of magnitude due to preconcentration of the sample and reduction of background noise, contributing to signal suppression. The described procedure has shown linearity in a broad range of concentrations. The overall time of single analysis is short and requires ca. 5 min. The developed technique was applied for the determination of nicotine, propyphenazone, and methylparaben in spiked real-life samples, with recovery of 94.6-98.4%. The proposed method is rapid, sensitive, and accurate which provides a new option for the detection of small organic compounds in various samples. Graphical abstract The experimental setup used for analysis.
A gene for familial psoriasis susceptibility maps to the distal end of human chromosome 17q
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bowcock, A.; Tomfohrde, J.; Barnes, R.
1994-09-01
Psoriasis is a chronic inflammatory dermatosis that affects approximately 2% of the population. A gene for psoriasis susceptibility was localized to the distal region of human chromosome 17q as a result of a genome wide linkage-analysis with polymorphic microsatellites and eight multiply affected psoriasis kindreds. With one large kindred a maximum two-point lod score with D17S784 was 5.70 at 15% recombination. Heterogeneity testing indicated that psoriasis susceptibility in 50% of the families was linked to distal 17q. Susceptibility to psoriasis has repeatedly been found to be associated with HLA-Cw6 and associated HLA alleles. We therefore genotyped the families for locimore » within and flanking HLA; these included PCR assays for susceptibility alleles. By lod score analysis no evidence of linkage of psoriasis susceptibility to HLA was detected. The distribution of HLA-Cw6 and HLA-Class II alleles showed that HLA-Cw6 was frequent among patients, particularly in 4 of the 5 unlinked families. All affected members of two of these unlinked families carried HLA-Cw6 (empirical P values of 0.027 and 0.004). In 2 other families 4 of 6 and 6 of 7 had HLA-Cw6. In some of these families, an inability to detect linkage to HLA may have been due to the occurrence of multiple haplotypes carrying the psoriasis associated allele, HLA-Cw6. Contrasting with these findings, we observed a lack of association between HLA-Cw6 and psoriasis in the 3 families in which 17q markers were linked to susceptibility. The ability to detect linkage to 17q confirms that some forms of familial psoriasis are due to molecular defects at a single major genetic locus other than HLA.« less
Müller, M H B; Polder, A; Brynildsrud, O B; Karimi, M; Lie, E; Manyilizu, W B; Mdegela, R H; Mokiti, F; Murtadha, M; Nonga, H E; Skaare, J U; Lyche, J L
2017-04-01
This is the first study to report organochlorines (OCs), including chlorinated pesticides (OCPs) and polychlorinated biphenyls (PCBs) in human milk from Tanzania. The main aims of this study were to assess the level of contamination and the possible health risks related to OC exposure in nursing infants from the Northern parts of Tanzania. Ninety-five healthy mother-infant couples attending Mount Meru Regional Referral Hospital (MMRRH), Arusha, Tanzania, were assessed for associations between maternal/infant characteristics, i.e. mother's age, BMI, gestational weight gain, occupation, residence and fetal growth parameters and breast milk levels of OCPs, such as dichlorodiphenyltrichloroethane (DDT) and its metabolites, dieldrin and PCBs. p,p'-DDE and p,p'-DDT were detected in 100% and 75% of the breast milk samples, respectively, and ranged between 24 and 2400ng/g lipid weight (lw) and
NASA Astrophysics Data System (ADS)
Rahman, Mahbubur; Heng, Lee Yook; Futra, Dedi; Ling, Tan Ling
2017-08-01
An ultrasensitive electrochemical biosensor for the determination of pathogenic Vibrio cholerae ( V. cholerae) DNA was developed based on polystyrene-co-acrylic acid (PSA) latex nanospheres-gold nanoparticles composite (PSA-AuNPs) DNA carrier matrix. Differential pulse voltammetry (DPV) using an electroactive anthraquninone oligonucleotide label was used for measuring the biosensor response. Loading of gold nanoparticles (AuNPs) on the DNA-latex particle electrode has significantly amplified the faradaic current of DNA hybridisation. Together with the use of a reported probe, the biosensor has demonstrated high sensitivity. The DNA biosensor yielded a reproducible and wide linear response range to target DNA from 1.0 × 10-21 to 1.0 × 10-8 M (relative standard deviation, RSD = 4.5%, n = 5) with a limit of detection (LOD) of 1.0 × 10-21 M ( R 2 = 0.99). The biosensor obtained satisfactory recovery values between 91 and 109% ( n = 3) for the detection of V. cholerae DNA in spiked samples and could be reused for six consecutive DNA assays with a repeatability RSD value of 5% ( n = 5). The electrochemical biosensor response was stable and maintainable at 95% of its original response up to 58 days of storage period.
Determination of Aflatoxin B1 in Smokeless Tobacco Products by use of UHPLC-MS/MS
Zitomer, Nicholas; Rybak, Michael E.; Li, Zhong; Walters, Matthew J.; Holman, Matthew R.
2017-01-01
We have developed a UHPLC-MS/MS method for the detection and quantitation of aflatoxins in smokeless tobacco products and used it to determine aflatoxin B1 concentrations in 32 smokeless tobacco products commercially available in the US. Smokeless tobacco products were dried, milled and amended with 13C17-labelled internal standards, extracted in water/methanol solution in the presence of a surfactant, isolated through use of immunoaffinity column chromatography and reconstituted in mobile phase prior to UHPLC-MS/MS analysis. Our method was capable of baseline separation of aflatoxins B1, B2, G1 and G2 in a 2.5 min run by use of a fused core C18 column and a water/methanol gradient. MS/MS transition (m/z) 313.3>241.2 was used for aflatoxin B1 quantitation, with 313.3>285.1 used for confirmation. The limit of detection (LOD) for aflatoxin B1 was 0.007 parts per billion (ppb). Method imprecision for aflatoxin B1 (expressed as coefficient of variation) ranged from 5.5% to 9.4%. Spike recoveries were 105–111%. Aflatoxin B1 concentrations in the smokeless tobacco products analysed ranged from
Differential Genetic Basis for Pre-Menopausal and Post-Menopausal Salt-Sensitive Hypertension
Herrera, Victoria L. M.; Pasion, Khristine A.; Moran, Ann Marie; Ruiz-Opazo, Nelson
2012-01-01
Essential hypertension affects 75% of post-menopausal women in the United States causing greater cardiovascular complications compared with age-matched men and pre-menopausal women. Hormone replacement and current anti-hypertensive therapies do not correct this post-menopausal increased risk suggesting a distinct pathogenic framework. We investigated the hypothesis that distinct genetic determinants might underlie susceptibility to salt sensitive hypertension in pre-menopausal and post-menopausal states. To determine whether distinct genetic loci contribute to post-menopausal salt-sensitive hypertension, we performed a genome-wide scan for quantitative trait loci (QTLs) affecting blood pressure (BP) in 16-month old post-menopausal F2 (Dahl S×R)-intercross female rats characterized for blood pressure by radiotelemetry. Given identical environments and high salt challenge, post-menopausal BP levels were significantly higher than observed in pre-menopausal (post-menopausal versus pre-menopausal SBP, P<0.0001) and ovariectomized (post-menopausal versus ovariectomized SBP, P<0.001) F2-intercross female rats. We detected four significant to highly significant BP-QTLs (BP-pm1 on chromosome 13, LOD 3.78; BP-pm2 on chromosome 11, LOD 2.76; BP-pm3 on chromosome 2, LOD 2.61; BP-pm4 on chromosome 4, LOD 2.50) and two suggestive BP-QTLs (BP-pm5 on chromosome 15, LOD 2.37; BP-f1 on chromosome 5, LOD 1.65), four of which (BP-pm2, BP-pm3, BP-pm4, BP-pm5) were unique to this post-menopausal cohort. These data demonstrate distinct polygenic susceptibility underlying post-menopausal salt-sensitive hypertension providing a pathway towards the identification of mechanism-based therapy for post-menopausal hypertension and ensuing target-organ complications. PMID:22912817
Differential genetic basis for pre-menopausal and post-menopausal salt-sensitive hypertension.
Herrera, Victoria L M; Pasion, Khristine A; Moran, Ann Marie; Ruiz-Opazo, Nelson
2012-01-01
Essential hypertension affects 75% of post-menopausal women in the United States causing greater cardiovascular complications compared with age-matched men and pre-menopausal women. Hormone replacement and current anti-hypertensive therapies do not correct this post-menopausal increased risk suggesting a distinct pathogenic framework. We investigated the hypothesis that distinct genetic determinants might underlie susceptibility to salt sensitive hypertension in pre-menopausal and post-menopausal states. To determine whether distinct genetic loci contribute to post-menopausal salt-sensitive hypertension, we performed a genome-wide scan for quantitative trait loci (QTLs) affecting blood pressure (BP) in 16-month old post-menopausal F2 (Dahl S×R)-intercross female rats characterized for blood pressure by radiotelemetry. Given identical environments and high salt challenge, post-menopausal BP levels were significantly higher than observed in pre-menopausal (post-menopausal versus pre-menopausal SBP, P<0.0001) and ovariectomized (post-menopausal versus ovariectomized SBP, P<0.001) F2-intercross female rats. We detected four significant to highly significant BP-QTLs (BP-pm1 on chromosome 13, LOD 3.78; BP-pm2 on chromosome 11, LOD 2.76; BP-pm3 on chromosome 2, LOD 2.61; BP-pm4 on chromosome 4, LOD 2.50) and two suggestive BP-QTLs (BP-pm5 on chromosome 15, LOD 2.37; BP-f1 on chromosome 5, LOD 1.65), four of which (BP-pm2, BP-pm3, BP-pm4, BP-pm5) were unique to this post-menopausal cohort. These data demonstrate distinct polygenic susceptibility underlying post-menopausal salt-sensitive hypertension providing a pathway towards the identification of mechanism-based therapy for post-menopausal hypertension and ensuing target-organ complications.
Vortmann-Westhoven, Britta; Lürenbaum, Constantin; Winter, Martin; Nowak, Sascha
2017-02-01
In this work, we present a novel electrophoretic method that was developed for the determination of lithium and transition metals in LiNi 1/3 Co 1/3 Mn 1/3 O 2 cathode material after microwave digestion. The cations in the digested LiNi 1/3 Co 1/3 Mn 1/3 O 2 material were separated by CE and the element content was determined by UV/Vis detection. To characterize the precision of the measurements, the RSDs and concentrations were calculated and compared to those obtained with ICP-optical emission spectrometry (ICP-OES). Furthermore, a certified reference material (BCR 176R-fly ash) was investigated for all techniques. For active material components, the LOD and LOQ were determined. The LODs and LOQs for the metals determined by CE were as follows: lithium (LOD/LOQ): 17.41/62.70 μg/L, cobalt (LOD/LOQ): 348.4/1283 μg/L, manganese (LOD/LOQ): 540.2/2095 μg/L, and nickel (LOD/LOQ): 838.0/2982 μg/L. Recovery rates for lithium were in the range of 95-103%. It could be proven that with the new technique, the results for the determination of the lithium content of active material were comparable with those obtained by ICP-OES and ion chromatography. Furthermore, the recovery rates of the transition metals were determined to be between 96 and 110% by CE and ICP-OES. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Sayago, Isabel; Matatagui, Daniel; Fernández, María Jesús; Fontecha, José Luis; Jurewicz, Izabela; Garriga, Rosa; Muñoz, Edgar
2016-02-01
A Love-wave device with graphene oxide (GO) as sensitive layer has been developed for the detection of chemical warfare agent (CWA) simulants. Sensitive films were fabricated by airbrushing GO dispersions onto Love-wave devices. The resulting Love-wave sensors detected very low CWA simulant concentrations in synthetic air at room temperature (as low as 0.2 ppm for dimethyl-methylphosphonate, DMMP, a simulant of sarin nerve gas, and 0.75 ppm for dipropylene glycol monomethyl ether, DPGME, a simulant of nitrogen mustard). High responses to DMMP and DPGME were obtained with sensitivities of 3087 and 760 Hz/ppm respectively. Very low limit of detection (LOD) values (9 and 40 ppb for DMMP and DPGME, respectively) were calculated from the achieved experimental data. The sensor exhibited outstanding sensitivity, good linearity and repeatability to all simulants tested. The detection mechanism is here explained in terms of hydrogen bonding formation between the tested CWA simulants and GO. Copyright © 2015 Elsevier B.V. All rights reserved.
Multilocus lod scores in large pedigrees: combination of exact and approximate calculations.
Tong, Liping; Thompson, Elizabeth
2008-01-01
To detect the positions of disease loci, lod scores are calculated at multiple chromosomal positions given trait and marker data on members of pedigrees. Exact lod score calculations are often impossible when the size of the pedigree and the number of markers are both large. In this case, a Markov Chain Monte Carlo (MCMC) approach provides an approximation. However, to provide accurate results, mixing performance is always a key issue in these MCMC methods. In this paper, we propose two methods to improve MCMC sampling and hence obtain more accurate lod score estimates in shorter computation time. The first improvement generalizes the block-Gibbs meiosis (M) sampler to multiple meiosis (MM) sampler in which multiple meioses are updated jointly, across all loci. The second one divides the computations on a large pedigree into several parts by conditioning on the haplotypes of some 'key' individuals. We perform exact calculations for the descendant parts where more data are often available, and combine this information with sampling of the hidden variables in the ancestral parts. Our approaches are expected to be most useful for data on a large pedigree with a lot of missing data. (c) 2007 S. Karger AG, Basel
Multilocus Lod Scores in Large Pedigrees: Combination of Exact and Approximate Calculations
Tong, Liping; Thompson, Elizabeth
2007-01-01
To detect the positions of disease loci, lod scores are calculated at multiple chromosomal positions given trait and marker data on members of pedigrees. Exact lod score calculations are often impossible when the size of the pedigree and the number of markers are both large. In this case, a Markov Chain Monte Carlo (MCMC) approach provides an approximation. However, to provide accurate results, mixing performance is always a key issue in these MCMC methods. In this paper, we propose two methods to improve MCMC sampling and hence obtain more accurate lod score estimates in shorter computation time. The first improvement generalizes the block-Gibbs meiosis (M) sampler to multiple meiosis (MM) sampler in which multiple meioses are updated jointly, across all loci. The second one divides the computations on a large pedigree into several parts by conditioning on the haplotypes of some ‘key’ individuals. We perform exact calculations for the descendant parts where more data are often available, and combine this information with sampling of the hidden variables in the ancestral parts. Our approaches are expected to be most useful for data on a large pedigree with a lot of missing data. PMID:17934317
Rapid development of new protein biosensors utilizing peptides obtained via phage display.
Wu, Jun; Park, Jong Pil; Dooley, Kevin; Cropek, Donald M; West, Alan C; Banta, Scott
2011-01-01
There is a consistent demand for new biosensors for the detection of protein targets, and a systematic method for the rapid development of new sensors is needed. Here we present a platform where short unstructured peptides that bind to a desired target are selected using M13 phage display. The selected peptides are then chemically synthesized and immobilized on gold, allowing for detection of the target using electrochemical techniques such as electrochemical impedance spectroscopy (EIS). A quartz crystal microbalance (QCM) is also used as a diagnostic tool during biosensor development. We demonstrate the utility of this approach by creating a novel peptide-based electrochemical biosensor for the enzyme alanine aminotransferase (ALT), a well-known biomarker of hepatotoxicity. Biopanning of the M13 phage display library over immobilized ALT, led to the rapid identification of a new peptide (ALT5-8) with an amino acid sequence of WHWRNPDFWYLK. Phage particles expressing this peptide exhibited nanomolar affinity for immobilized ALT (K(d,app) = 85±20 nM). The newly identified ALT5-8 peptide was then chemically synthesized with a C-terminal cysteine for gold immobilization. The performance of the gold-immobilized peptides was studied with cyclic voltammetry (CV), QCM, and EIS. Using QCM, the sensitivity for ALT detection was 8.9±0.9 Hz/(µg/mL) and the limit of detection (LOD) was 60 ng/mL. Using EIS measurements, the sensitivity was 142±12 impedance percentage change %/(µg/mL) and the LOD was 92 ng/mL. In both cases, the LOD was below the typical concentration of ALT in human blood. Although both QCM and EIS produced similar LODs, EIS is preferable due to a larger linear dynamic range. Using QCM, the immobilized peptide exhibited a nanomolar dissociation constant for ALT (K(d) = 20.1±0.6 nM). These results demonstrate a simple and rapid platform for developing and assessing the performance of sensitive, peptide-based biosensors for new protein targets.
Martan, T; Nemecek, T; Komanec, M; Ahmad, R; Zvanovec, S
2017-03-20
Detecting explosive, flammable, or toxic industrial liquids reliably and accurately is a matter of civic responsibility that cannot be treated lightly. Tapered optical fibers (TOFs) and suspended core microstructured optical fibers (SC MOFs) were separately used as sensors of liquids without being compared to each other. We present a highly sensitive time-stable TOF sensor incorporated in the pipeline system for the in-line regime of measurement. This paper is furthermore focused on the comparison of this TOF and SC MOF of similar parameters for the detection of selected liquids. A validated method that incorporates TOF and SC MOF of small core (waist) diameter for refractometric detection is presented. The principle of detection is based on the overlap of an enhanced evanescent wave with a liquid analyte that either fills the cladding holes of the SC MOF or surrounds the waist area of the TOF. Optical power within the evanescent wave for both sensing structures and selected liquid analytes is analyzed. Measurement results concerning TOF and SC MOF are compared. Calculations to ascertain the limit of detection (LOD) for each sensor and the sensitivity (S) to refractive indices of liquid analytes in the range of 1.4269 to 1.4361 were performed at a wavelength of 1550 nm with the lowest refractive index step of 0.0007. Results affirming that S=600.96 dB/RIU and LOD=0.0733 RIU for the SC MOF and S=1143.2 dB/RIU and LOD of 0.0026 RIU for the TOF sensor were achieved, clearly illustrating that TOF-based sensors can reach close to two times greater sensitivity and 30 times higher limit of detection. This paper extends the comparison of the fiber sensors by discussing the potential applications.
Sensitivity of lod scores to changes in diagnostic status.
Hodge, S E; Greenberg, D A
1992-01-01
This paper investigates effects on lod scores when one individual in a data set changes diagnostic or recombinant status. First we examine the situation in which a single offspring in a nuclear family changes status. The nuclear-family situation, in addition to being of interest in its own right, also has general theoretical importance, since nuclear families are "transparent"; that is, one can track genetic events more precisely in nuclear families than in complex pedigrees. We demonstrate that in nuclear families log10 [(1-theta)/theta] gives an upper limit on the impact that a single offspring's change in status can have on the lod score at that recombination fraction (theta). These limits hold for a fully penetrant dominant condition and fully informative marker, in either phase-known or phase-unknown matings. Moreover, log10 [(1-theta)/theta] (where theta denotes the value of theta at which Zmax occurs) gives an upper limit on the impact of a single offspring's status change on the maximum lod score (Zmax). In extended pedigrees, in contrast to nuclear families, no comparable limit can be set on the impact of a single individual on the lod score. Complex pedigrees are subject to both stabilizing and destabilizing influences, and these are described. Finally, we describe a "sensitivity analysis," in which, after all linkage analysis is completed, every informative individual in the data set is changed, one at a time, to see the effect which each separate change has on the lod scores. The procedure includes identifying "critical individuals," i.e., those who would have the greatest impact on the lod scores, should their diagnostic status in fact change. To illustrate use of the sensitivity analysis, we apply it to the large bipolar pedigree reported by Egeland et al. and Kelsoe et al. We show that the changes in lod scores observed there, on the order of 1.1-1.2 per person, are not unusual. We recommend that investigators include a sensitivity analysis as a standard part of reporting the results of a linkage analysis. PMID:1570835
Sensitivity of lod scores to changes in diagnostic status.
Hodge, S E; Greenberg, D A
1992-05-01
This paper investigates effects on lod scores when one individual in a data set changes diagnostic or recombinant status. First we examine the situation in which a single offspring in a nuclear family changes status. The nuclear-family situation, in addition to being of interest in its own right, also has general theoretical importance, since nuclear families are "transparent"; that is, one can track genetic events more precisely in nuclear families than in complex pedigrees. We demonstrate that in nuclear families log10 [(1-theta)/theta] gives an upper limit on the impact that a single offspring's change in status can have on the lod score at that recombination fraction (theta). These limits hold for a fully penetrant dominant condition and fully informative marker, in either phase-known or phase-unknown matings. Moreover, log10 [(1-theta)/theta] (where theta denotes the value of theta at which Zmax occurs) gives an upper limit on the impact of a single offspring's status change on the maximum lod score (Zmax). In extended pedigrees, in contrast to nuclear families, no comparable limit can be set on the impact of a single individual on the lod score. Complex pedigrees are subject to both stabilizing and destabilizing influences, and these are described. Finally, we describe a "sensitivity analysis," in which, after all linkage analysis is completed, every informative individual in the data set is changed, one at a time, to see the effect which each separate change has on the lod scores. The procedure includes identifying "critical individuals," i.e., those who would have the greatest impact on the lod scores, should their diagnostic status in fact change. To illustrate use of the sensitivity analysis, we apply it to the large bipolar pedigree reported by Egeland et al. and Kelsoe et al. We show that the changes in lod scores observed there, on the order of 1.1-1.2 per person, are not unusual. We recommend that investigators include a sensitivity analysis as a standard part of reporting the results of a linkage analysis.
Chen, Xi; Chen, Jin; Wang, Fubin; Xiang, Xia; Luo, Ming; Ji, Xinghu; He, Zhike
2012-05-15
In this work, we first employ a drying method combining with the bienzyme colorimetric detection of glucose and uric acid on microfluidic paper-based analysis devices (μPADs). The channels of 3D μPADs are also designed by us to get better results. The color results are recorded by both Gel Documentation systems and a common camera. By using Gel Documentation systems, the limits of detection (LOD) of glucose and uric acid are 3.81 × 10(-5)M and 4.31 × 10(-5)M, respectively one order of magnitude lower than that of the reported methods on μPADs. By using a common camera, the limits of detection (LOD) of glucose and uric acid are 2.13 × 10(-4)M and 2.87 × 10(-4)M, respectively. Furthermore, the effects of detection conditions have been investigated and discussed comprehensively. Human serum samples are detected with satisfactory results, which are comparable with the clinical testing results. A low-cost, simple and rapid colorimetric method for the simultaneous detection of glucose and uric acid on the μPADs has been developed with enhanced sensitivity. Copyright © 2012 Elsevier B.V. All rights reserved.
Evaluation of analytical performance of a new high-sensitivity immunoassay for cardiac troponin I.
Masotti, Silvia; Prontera, Concetta; Musetti, Veronica; Storti, Simona; Ndreu, Rudina; Zucchelli, Gian Carlo; Passino, Claudio; Clerico, Aldo
2018-02-23
The study aim was to evaluate and compare the analytical performance of the new chemiluminescent immunoassay for cardiac troponin I (cTnI), called Access hs-TnI using DxI platform, with those of Access AccuTnI+3 method, and high-sensitivity (hs) cTnI method for ARCHITECT platform. The limits of blank (LoB), detection (LoD) and quantitation (LoQ) at 10% and 20% CV were evaluated according to international standardized protocols. For the evaluation of analytical performance and comparison of cTnI results, both heparinized plasma samples, collected from healthy subjects and patients with cardiac diseases, and quality control samples distributed in external quality assessment programs were used. LoB, LoD and LoQ at 20% and 10% CV values of the Access hs-cTnI method were 0.6, 1.3, 2.1 and 5.3 ng/L, respectively. Access hs-cTnI method showed analytical performance significantly better than that of Access AccuTnI+3 method and similar results to those of hs ARCHITECT cTnI method. Moreover, the cTnI concentrations measured with Access hs-cTnI method showed close linear regressions with both Access AccuTnI+3 and ARCHITECT hs-cTnI methods, although there were systematic differences between these methods. There was no difference between cTnI values measured by Access hs-cTnI in heparinized plasma and serum samples, whereas there was a significant difference between cTnI values, respectively measured in EDTA and heparin plasma samples. Access hs-cTnI has analytical sensitivity parameters significantly improved compared to Access AccuTnI+3 method and is similar to those of the high-sensitivity method using ARCHITECT platform.
López-Gutiérrez, Noelia; Romero-González, Roberto; Garrido Frenich, Antonia; Martínez Vidal, José Luis
2014-06-27
The specific phytochemicals composition of soy nutritional supplements is usually not labelled. Hence, 12 dietary supplements were analyzed in order to detect and identify the main phytochemicals present in these samples, using a database containing 60 compounds. Ultra-high performance liquid chromatography coupled to single-stage Orbitrap high resolution mass spectrometry (UHPLC-Orbitrap-MS) has been used. Two consecutive extractions, using as extraction solvent a mixture of methanol:water (80:20, v/v), were employed, followed by two dilutions (10 or 100 times depending on the concentration of the components in the sample) with a mixture of an aqueous solution of ammonium acetate 30mM:methanol (50:50, v/v). The method was validated, obtaining adequate recovery and precision values. Limits of detection (LODs) and quantification (LOQs) were calculated, ranging from 2 to 150μgL(-1). Isoflavones were the predominant components present in the analyzed supplements with values higher than 93% of the total amount of phytochemicals in all cases. The aglycones (genistein, daidzein, glycitein and biochanin A) as well as their three conjugated forms, β-glucosides (genistin, daizin and glycitin) were detected and quantified, being daidzein the isoflavone detected at higher concentration in 8 out of 12 samples reported, with values ranging from 684 to 35,970mgkg(-1), whereas biochanin A was detected at very low concentrations, ranging from 18 to 50mgkg(-1). Moreover, other phytochemicals as flavones, flavonols, flavanones and phenolic acids were also detected and quantified. Copyright © 2014 Elsevier B.V. All rights reserved.
Abdul Keyon, Aemi S; Guijt, Rosanne M; Bolch, Christopher J S; Breadmore, Michael C
2014-10-17
The accumulation of paralytic shellfish toxins (PSTs) in contaminated shellfish is a serious health risk making early detection important to improve shellfish safety and biotoxin management. Capillary electrophoresis (CE) has been proven as a high resolution separation technique compatible with miniaturization, making it an attractive choice in the development of portable instrumentation for early, on-site detection of PSTs. In this work, capillary zone electrophoresis (CZE) with capacitively coupled contactless conductivity detector (C(4)D) and UV detection were examined with counter-flow transient isotachophoresis (tITP) to improve the sensitivity and deal with the high conductivity sample matrix. The high sodium concentration in the sample was used as the leading ion while l-alanine was used as the terminating electrolyte (TE) and background electrolyte (BGE) in which the toxins were separated. Careful optimization of the injected sample volume and duration of the counter-flow resulted in limit of detections (LODs) ranging from 74.2 to 1020 ng/mL for tITP-CZE-C(4)D and 141 to 461 ng/mL for tITP-CZE-UV, an 8-97 fold reduction compared to conventional CZE. The LODs were adequate for the analysis of PSTs in shellfish samples close to the regulatory limit. Intra-day and inter-day repeatability values (percentage relative standard deviation, n=3) of tITP-CZE-C(4)D and tITP-CZE-UV methods for both migration time and peak height were in the range of 0.82-11% and 0.76-10%, respectively. The developed method was applied to the analysis of a contaminated mussel sample and validated against an Association of Official Analytical Chemists (AOAC)-approved method for PSTs analysis by high performance liquid chromatography (HPLC) with fluorescence detection (FLD) after pre-column oxidation of the sample. The method presented has potential for incorporation in to field-deployable devices for the early detection of PSTs on-site. Copyright © 2014 Elsevier B.V. All rights reserved.
Tabb, Keri L.; Hellwege, Jacklyn N.; Palmer, Nicholette D.; Dimitrov, Latchezar; Sajuthi, Satria; Taylor, Kent D.; NG, Maggie C.Y.; Hawkins, Gregory A.; Chen, Yii-Der Ida; Brown, W. Mark; McWilliams, David; Williams, Adrienne; Lorenzo, Carlos; Norris, Jill M.; Long, Jirong; Rotter, Jerome I.; Curran, Joanne E.; Blangero, John; Wagenknecht, Lynne E.; Langefeld, Carl D.; Bowden, Donald W.
2017-01-01
Summary Family-based methods are a potentially powerful tool to identify trait-defining genetic variants in extended families, particularly when used to complement conventional association analysis. We utilized two-point linkage analysis and single variant association analysis to evaluate whole exome sequencing (WES) data from 1,205 Hispanic Americans (78 families) from the Insulin Resistance Atherosclerosis Family Study. WES identified 211,612 variants above the minor allele frequency threshold of ≥0.005. These variants were tested for linkage and/or association with 50 cardiometabolic traits after quality control checks. Two-point linkage analysis yielded 10,580,600 LOD scores with 1,148 LOD scores ≥3, 183 LOD scores ≥4, and 29 LOD scores ≥5. The maximal novel LOD score was 5.50 for rs2289043:T>C, in UNC5C with subcutaneous adipose tissue volume. Association analysis identified 13 variants attaining genome-wide significance (p<5×10-08), with the strongest association between rs651821:C>T in APOA5, and triglyceride levels (p=3.67×10-10). Overall, there was a 5.2-fold increase in the number of informative variants detected by WES compared to exome chip analysis in this population, nearly 30% of which were novel variants relative to dbSNP build 138. Thus, integration of results from two-point linkage and single-variant association analysis from WES data enabled identification of novel signals potentially contributing to cardiometabolic traits. PMID:28067407
Kynurenine pathway changes in late-life depression.
Wu, Yujie; Zhong, Xiaomei; Mai, Naikeng; Wen, Yuguan; Shang, Dewei; Hu, Lijun; Chen, Ben; Zhang, Min; Ning, Yuping
2018-08-01
Kynurenine pathway (KP) activation is associated with several neuropsychiatric diseases, including major depression disorder (MDD). Although several investigations have been conducted on MDD, these have seldom shed light on KP changes in late-life depression (LLD). We aimed to investigate whether tryptophan (TRP) metabolism and kynurenine (KYN) metabolism are imbalanced in LLD patients and to explore the differences in KP characteristics between early onset depression (EOD) and late onset depression (LOD) patients. We investigated 170 LLD patients (EOD 90, LOD 80) and 135 normal controls. Serum concentrations of TRP, KYN and kynurenic acid (KYNA) were detected by the liquid chromatography-tandem mass spectrometry method. Depressive symptoms were assessed by the 17-item Hamilton Depression Scale (HAMD-17). LLD patients exhibited lower levels of TRP, KYN, KYNA and KYNA/KYN ratio and a higher level of KYN/TRY ratio than normal controls. The decrease in TRP and the increase in KYN/TRP ratio were found in LOD patients. A low TRP level without increased KYN/TRP ratio was found in EOD patients. The "Depression" factor, which was extracted from HAMD-17 by the principal component factor analysis, was correlated with the TRP level and KYNA/KYN ratio in the EOD group, but no such correlation was found in the LOD group. KP changes were observed in LLD patients; LOD patients showed profound shifts in TRP metabolism, while EOD patients showed low TRP level and a shift in KYN metabolism. Copyright © 2018 Elsevier B.V. All rights reserved.
Smoothing of the bivariate LOD score for non-normal quantitative traits.
Buil, Alfonso; Dyer, Thomas D; Almasy, Laura; Blangero, John
2005-12-30
Variance component analysis provides an efficient method for performing linkage analysis for quantitative traits. However, type I error of variance components-based likelihood ratio testing may be affected when phenotypic data are non-normally distributed (especially with high values of kurtosis). This results in inflated LOD scores when the normality assumption does not hold. Even though different solutions have been proposed to deal with this problem with univariate phenotypes, little work has been done in the multivariate case. We present an empirical approach to adjust the inflated LOD scores obtained from a bivariate phenotype that violates the assumption of normality. Using the Collaborative Study on the Genetics of Alcoholism data available for the Genetic Analysis Workshop 14, we show how bivariate linkage analysis with leptokurtotic traits gives an inflated type I error. We perform a novel correction that achieves acceptable levels of type I error.
In situ Spectroscopic Analysis and Quantification of [Tc(CO)3]+ in Hanford Tank Waste.
Branch, Shirmir D; French, Amanda D; Lines, Amanda M; Soderquist, Chuck Z; Rapko, Brian M; Heineman, William R; Bryan, Samuel A
2018-06-12
The quantitative conversion of non-pertechnetate [Tc(CO)3]+ species in nuclear waste storage tank 241-AN-102 at the Hanford Site is demonstrated. A waste sample containing the [Tc(CO)3]+ species is added to a developer solution that rapidly converts the non-emissive species into a luminescent complex, which is detected spectroscopically. This method was first demonstrated using a [Tc(CO)3]+ sample non-waste containing matrix to determine a detection limit (LOD), resulting in a [Tc(CO)3]+ LOD of 2.20 × 10-7 M, very near the LOD of the independently synthesized standard (2.10 × 10-7 M). The method was then used to detect [Tc(CO)3]+ in a simulated waste using the standard addition method, resulting in a [Tc(CO)3]+ concentration of 1.89 × 10-5 M (within 27.7% of the concentration determined by β- liquid scintillation counting). Three samples from 241-AN-102 were tested by the standard addition method: (1) a 5 M Na adjusted fraction, (2) a fraction depleted of 137Cs, (3) and an acid-stripped eluate. The concentrations of [Tc(CO)3]+ in these fractions were determined to be 9.90 × 10-6 M (1), 0 M (2), and 2.46 × 10-6 M (3), respectively. The concentration of [Tc(CO)3]+ in the as-received AN-102 tank waste supernatant was determined to be 1.84 × 10-5 M.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pulver, A.E.; Lasseter, V.K.; Kasch, L.
Using a systematically ascertained sample of 57 families, each having 2 or more members with a consensus diagnosis of schizophrenia (DSM-III-R criteria), we have carried out linkage studies of 520 loci, covering approximately 70% of the genome for susceptibility loci for schizophrenia. A two-stage strategy based on lod score thresholds from simulation studies of our sample identified regions for further exploration. In each region, a dense map of highly informative dinucleotide repeat polymorphisms (heterozygosity greater than .70) was analyzed using dominant, recessive, and {open_quotes}affected only{close_quotes} models and nonparametric sib pair identity-by-descent methods. For one region, 8p22-p21, affected sib-pair analyses gavemore » a P value = .0001, corresponding to a lod score approximately equal to 3.00. For 8p22-p21, the maximum two-point lod score occurred using the {open_quotes}affected only{close_quotes} recessive model (Z{sub max} = 2.35; {theta}{sub M} = {theta}{sub F}); allowing for a constant sex difference in recombination fractions found in reference pedigrees, Z{sub max} = 2.78 ({theta}{sub M}/{theta}{sub F} = 3). For a second region, 3p26-p24, the maximum two-point lod score was 2.34 ({open_quotes}affected only{close_quotes} dominant model), and the affected sib-pair P value was .01. These two regions are worthy of further exploration as potential sites of susceptibility genes for schizophrenia. 59 refs., 2 figs., 4 tabs.« less
NASA Astrophysics Data System (ADS)
Ranamukhaarachchi, Sahan A.; Padeste, Celestino; Dübner, Matthias; Häfeli, Urs O.; Stoeber, Boris; Cadarso, Victor J.
2016-07-01
Therapeutic drug monitoring (TDM) typically requires painful blood drawn from patients. We propose a painless and minimally-invasive alternative for TDM using hollow microneedles suitable to extract extremely small volumes (<1 nL) of interstitial fluid to measure drug concentrations. The inner lumen of a microneedle is functionalized to be used as a micro-reactor during sample collection to trap and bind target drug candidates during extraction, without requirements of sample transfer. An optofluidic device is integrated with this microneedle to rapidly quantify drug analytes with high sensitivity using a straightforward absorbance scheme. Vancomycin is currently detected by using volumes ranging between 50-100 μL with a limit of detection (LoD) of 1.35 μM. The proposed microneedle-optofluidic biosensor can detect vancomycin with a sample volume of 0.6 nL and a LoD of <100 nM, validating this painless point of care system with significant potential to reduce healthcare costs and patients suffering.
Whitehouse, Chris A.; Chase, Kitty; Embers, Monica E.; Kulesh, David A.; Ladner, Jason T.; Palacios, Gustavo F.; Minogue, Timothy D.
2016-01-01
Background Moraxella macacae is a recently described bacterial pathogen that causes epistaxis or so-called bloody nose syndrome in captive macaques. The aim of this study was to develop specific molecular diagnostic assays for M. macacae and to determine their performance characteristics. Methods We developed six real-time PCR assays on the Roche LightCycler. The accuracy, precision, selectivity, and limit of detection (LOD) were determined for each assay, in addition to further validation by testing nasal swabs from macaques presenting with epistaxis at the Tulane National Primate Research Center. Results All assays exhibited 100% specificity and were highly sensitive with an LOD of 10 fg for chromosomal assays and 1 fg for the plasmid assay. Testing of nasal swabs from 10 symptomatic macaques confirmed the presence of M. macacae in these animals. Conclusions We developed several accurate, sensitive, and species-specific real-time PCR assays for the detection of M. macacae in captive macaques. PMID:26365904
Production of anatoxin-a by cyanobacterial strains isolated from Portuguese fresh water systems.
Osswald, Joana; Rellán, Sandra; Gago-Martinez, Ana; Vasconcelos, Vítor
2009-11-01
The occurrence of anatoxin-a in several freshwater systems in Portugal and its production by Portuguese cyanobacterial strains, after cultivation in laboratory, were studied. Surface water samples from 9 water bodies, for recreational and human consumption usage, were surveyed for anatoxin-a presence and for obtaining cultures of pure cyanobacterial strains. Anatoxin-a analysis was performed by high performance liquid chromatography (HPLC) with fluorescence detection (FLD) followed by Mass Spectrometry (MS) confirmation. No anatoxin-a was detected in all the natural water samples (limit of detection (LOD) = 25 ng l(-1)) but among the 22 isolated cyanobacterial strains, 13 could produce anatoxin-a in laboratory conditions (LOD = 3 ng g(-1) dw). This proportion of anatoxin-a producing strains (59.1%) in laboratory is discussed considering the hypothesis that anatoxin-a is a more frequent metabolite in cyanobacteria than it was thought before and making its occurrence in Portuguese freshwaters almost certain. Therefore, health and ecological risks caused by anatoxin-a in Portugal, should be seriously considered.
Mode-mismatched confocal thermal-lens microscope with collimated probe beam
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cabrera, Humberto, E-mail: hcabrera@ictp.it; Centro Multidisciplinartio de Ciencias, Instituto Venezolano de Investigaciones Científicas; Korte, Dorota
2015-05-15
We report a thermal lens microscope (TLM) based on an optimized mode-mismatched configuration. It takes advantage of the coaxial counter propagating tightly focused excitation and collimated probe beams, instead of both focused at the sample, as it is in currently known TLM setups. A simple mathematical model that takes into account the main features of the instrument is presented. The confocal detection scheme and the introduction of highly collimated probe beam allow enhancing the versatility, limit of detection (LOD), and sensitivity of the instrument. The theory is experimentally verified measuring ethanol’s absorption coefficient at 532.8 nm. Additionally, the presented techniquemore » is applied for detection of ultra-trace amounts of Cr(III) in liquid solution. The achieved LOD is 1.3 ppb, which represents 20-fold enhancement compared to transmission mode spectrometric techniques and a 7.5-fold improvement compared to previously reported methods for Cr(III) based on thermal lens effect.« less
Ranamukhaarachchi, Sahan A.; Padeste, Celestino; Dübner, Matthias; Häfeli, Urs O.; Stoeber, Boris; Cadarso, Victor J.
2016-01-01
Therapeutic drug monitoring (TDM) typically requires painful blood drawn from patients. We propose a painless and minimally-invasive alternative for TDM using hollow microneedles suitable to extract extremely small volumes (<1 nL) of interstitial fluid to measure drug concentrations. The inner lumen of a microneedle is functionalized to be used as a micro-reactor during sample collection to trap and bind target drug candidates during extraction, without requirements of sample transfer. An optofluidic device is integrated with this microneedle to rapidly quantify drug analytes with high sensitivity using a straightforward absorbance scheme. Vancomycin is currently detected by using volumes ranging between 50–100 μL with a limit of detection (LoD) of 1.35 μM. The proposed microneedle-optofluidic biosensor can detect vancomycin with a sample volume of 0.6 nL and a LoD of <100 nM, validating this painless point of care system with significant potential to reduce healthcare costs and patients suffering. PMID:27380889
NASA Astrophysics Data System (ADS)
Zhang, Weiwei; Serna, Samuel; Le Roux, Xavier; Vivien, Laurent; Cassan, Eric
2016-05-01
Bio-detection based on CMOS technology boosts the miniaturization of detection systems and the success on highly efficient, robust, accurate, and low coast Lab-on-Chip detection schemes. Such on chip detection technologies have covered healthy related harmful gases, bio-chemical analytes, genetic micro RNA, etc. Their monitoring accuracy is mainly qualified in terms of sensitivity and limit of the detection (LOD) of the detection system. In this context, recently developed silicon on insulator (SOI) optical devices have displayed highly performant detection abilities that LOD could go beyond 10-8RIU and sensitivity could exceeds 103nm/RIU. The SOI integrated optical sensing devices include strip/slotted waveguide consisting in structures like Mach-Zehnder interferometers (MZI), ring resonators (RR), nano cavities, etc. Typically, hollow core RR and nano-cavities could exhibit higher sensitivity due to their optical mode confinement properties with a partial localization of the electric field in low index sensing regions than devices based on evanescent field tails outside of the optical cores. Furthermore, they also provide larger sensing areas for surface functionalization to reach higher sensitivities and lower LODs. The state of art of hollow core devices, either based on Bragg gratings formed from a slot waveguide cavity or photonic crystal slot cavities, show sensitivities (S) up to 400nm/RIU and Figure of Merit (FOM) around 3,000 in water environment, FOM being defined as the inverse of LOD and precisely as FOM=SQ/λ, with λ the resonance wavelength and Q the quality factor of the considered resonator. Such high achieved FOMs in nano cavities are mainly due to their large Q factors around 15,000. While for mostly used RR, which do not require particular design strategies, relatively low Q factors around 1800 in water are met and moderate sensitivities about 300nm/RIU are found. In this work, we present here a novel slot ring resonator design to make breakthrough of the performance of slot ring resonator sensing ability. Different from the normal sensing regime by monitoring one specific resonance (λres) peak shift, the proposed approach stems from the sensitivity of the RR critical coupling. The critical coupling peak is auto-selected out by matching the following condition: the ring resonator's round trip attenuation coefficient a(λ) being equal to the coupler self-coupling coefficient k(λ), thus resulting in the deepest extinction ratio (ER) among the spectrum RR comb. The obtained sensing comb, based on a V-shape spectrum envelop, is engineered by controlling a(λ) and k(λ) with opposite monotonicities. Both a(λ)and k(λ) are tuned to have a large dispersion along the wavelength, which means that |a(λ)-k(λ)| keeps rapidly increasing as λres is far away from λc, eliminating the resonance ER quickly down to 0. Experimentally, slot waveguide ring resonators with a radius of 50µm have been fabricated on a standard silicon platform with a Si thickness of 220nm, loaded by racetrack couplers with a straight coupling length of 20µm. Sensing experiments have been carried out by changing the top cladding material from a series of Cargille optical liquids with refraction index values ranging from 1.3 to 1.5. The Q factors of critical coupling resonances was monitored from 2,000 to 6,000, and measured wavelength shifts of this peak are from 1.41µm to 1.56µm. The maximum sensitivity of 1300nm/RIU is observed in the cladding index range 1.30-1.35. To conclude, a new sensing regime by tracking the critical coupling resonance λc of slot waveguide ring resonators is demonstrated. The reported sensitivity is up 1300nm/RIU around the water RI of 1.33, and the monitored sensing FOM is about 2300, which is very close to the FOM values achieved from nanobeam cavities. This work can thus contribute to future integrated optical sensing schemes based on slot RRs.
Rapid and label-free detection of protein a by aptamer-tethered porous silicon nanostructures.
Urmann, Katharina; Reich, Peggy; Walter, Johanna-Gabriela; Beckmann, Dieter; Segal, Ester; Scheper, Thomas
2017-09-10
Protein A, which is secreted by and displayed on the cell membrane of Staphylococcus aureus is an important biomarker for S. aureus. Thus, its rapid and specific detection may facilitate the pathogen identification and initiation of proper treatment. Herein, we present a simple, label-free and rapid optical biosensor enabling specific detection of protein A. Protein A-binding aptamer serves as the capture probe and is immobilized onto a nanostructured porous silicon thin film, which serves as the optical transducer element. We demonstrate high sensitivity of the biosensor with a linear detection range between 8 and 23μM. The apparent dissociation constant was determined as 13.98μM and the LoD is 3.17μM. Harnessing the affinity between protein A and antibodies, a sandwich assay format was developed to amplify the optical signal associated with protein A capture by the aptamer. Using this approach, we increase the sensitivity of the biosensor, resulting in a three times lower LoD. Copyright © 2017 Elsevier B.V. All rights reserved.
He, Kuo; Mao, Qingwen; Zang, Xiuyuan; Zhang, Yanyu; Li, Hui; Zhang, Donghao
2017-09-01
In this study, we report the production of a monoclonal broad-specificity monoclonal antibody (mAb) specific for amatoxins and development of an indirect competitive immunoassay for detection of amatoxins in mushroom samples. In the assay, the complete antigen (α-amanitin-OVA) was used as coating antigen, and amatoxins as competitor competes with coating antigen to bind with mAb. Using this approach, The half-maximum inhibition concentrations (IC 50 ) of α-amanitin, β-amanitin and γ-amanitin, and limits of detection (LODs, IC 15 ) were 66.3, 97.4, 163.1 ng/mL and 0.91, 0.98, 0.89 ng/mL, respectively. The LODs for α-amanitin, β-amanitin and γ-amanitin in mushroom samples were 4.55, 4.9, and 4.45 ng/mL. The spiked results were also confirmed by HPLC, which showed a good correlation (R 2 = 0.996) between the two methods. The results indicated that the developed assay was reliable and suitable for the detection of amatoxins in mushroom samples. Copyright © 2017. Published by Elsevier Ltd.
Lee, SangWook; Kim, Soyoun; Malm, Johan; Jeong, Ok Chan; Lilja, Hans; Laurell, Thomas
2014-01-01
Enriching the surface density of immobilized capture antibodies enhances the detection signal of antibody sandwich microarrays. In this study, we improved the detection sensitivity of our previously developed P-Si (porous silicon) antibody microarray by optimizing concentrations of the capturing antibody. We investigated immunoassays using a P-Si microarray at three different capture antibody (PSA - prostate specific antigen) concentrations, analyzing the influence of the antibody density on the assay detection sensitivity. The LOD (limit of detection) for PSA was 2.5ngmL−1, 80pgmL−1, and 800fgmL−1 when arraying the PSA antibody, H117 at the concentration 15µgmL−1, 35µgmL−1 and 154µgmL−1, respectively. We further investigated PSA spiked into human female serum in the range of 800fgmL−1 to 500ngmL−1. The microarray showed a LOD of 800fgmL−1 and a dynamic range of 800 fgmL−1 to 80ngmL−1 in serum spiked samples. PMID:24016590
Wang, Yunyun; Liu, Ye; Deng, Xinli; Cong, Yulong; Jiang, Xingyu
2016-12-15
Although conventional enzyme-linked immunosorbent assays (ELISA) and related assays have been widely applied for the diagnosis of diseases, many of them suffer from large error variance for monitoring the concentration of targets over time, and insufficient limit of detection (LOD) for assaying dilute targets. We herein report a readout mode of ELISA based on the binding between peptidic β-sheet structure and Congo Red. The formation of peptidic β-sheet structure is triggered by alkaline phosphatase (ALP). For the detection of P-Selectin which is a crucial indicator for evaluating thrombus diseases in clinic, the 'β-sheet and Congo Red' mode significantly decreases both the error variance and the LOD (from 9.7ng/ml to 1.1 ng/ml) of detection, compared with commercial ELISA (an existing gold-standard method for detecting P-Selectin in clinic). Considering the wide range of ALP-based antibodies for immunoassays, such novel method could be applicable to the analysis of many types of targets. Copyright © 2016 Elsevier B.V. All rights reserved.
Nameghi, Morteza Alinezhad; Danesh, Noor Mohammad; Ramezani, Mohammad; Hassani, Faezeh Vahdati; Abnous, Khalil; Taghdisi, Seyed Mohammad
2016-08-01
Analytical techniques for detection of ochratoxin A (OTA) in food products and blood serum are of great significance. In this study, a fluorescent aptasensor was developed for sensitive and specific detection of OTA, based on a DNA pyramid nanostructure (DPN) and PicoGreen (PG) dye. The designed aptasensor inherits characteristics of DPN, such as high stability and capacity for PG loading. PG, as a fluorescent dye, could bind to double-stranded DNA (dsDNA). In the absence of OTA, the pyramid structure of DPN remains intact, leading to a very strong fluorescence emission. Because of higher affinity of aptamer for its target relative to its complementary strand, upon addition of target, the pyramid structure of DPN is disassembled, leading to a weak fluorescence emission. The presented aptasensor showed high specificity toward OTA with a limit of detection (LOD) as low as 0.135 nM. Besides, the designed sensing strategy was successfully utilized to recognize OTA in serum and grape juice with LODs of 0.184 and 0.149 nM, respectively.
Guo, Jinchao; Yang, Litao; Liu, Xin; Zhang, Haibo; Qian, Bingjun; Zhang, Dabing
2009-08-12
The virus-resistant papaya (Carica papaya L.), Huanong no. 1, was the genetically modified (GM) fruit approved for growing in China in 2006. To implement the labeling regulation of GM papaya and its derivates, the development of papaya endogenous reference gene is very necessary for GM papaya detection. Herein, we reported one papaya specific gene, Chymopapain (CHY), as one suitable endogenous reference gene, used for GM papaya identification. Thereafter, we established the conventional and real-time quantitative PCR assays of the CHY gene. In the CHY conventional PCR assay, the limit of detection (LOD) was 25 copies of haploid papaya genome. In the CHY real-time quantitative PCR assay, both the LOD and the limit of quantification (LOQ) were as low as 12.5 copies of haploid papaya genome. Furthermore, we revealed the construct-specific sequence of Chinese GM papaya Huanong no. 1 and developed its conventional and quantitative PCR systems employing the CHY gene as endogenous reference gene. This work is useful for papaya specific identification and GM papaya detection.
Tudela, Rebeca; Ribas-Agustí, Albert; Buxaderas, Susana; Riu-Aumatell, Montserrat; Castellari, Massimo; López-Tamames, Elvira
2016-06-15
An ultrahigh-performance liquid chromatography (UHPLC)-tandem mass spectrometry (MS/MS) method was developed for the simultaneous determination of nine target indoles in sparkling wines. The proposed method requires minimal sample pretreatment, and its performance parameters (accuracy, repeatability, LOD, and matrix effect) indicate that it is suitable for routine analysis. Four indoles were found at detectable levels in commercial Cava samples: 5-methoxytryptophol (5MTL), tryptophan (TRP), tryptophan ethyl ester (TEE), and N-acetylserotonin (NSER). Two of them, NSER and 5MTL, are reported here for the first time in sparkling wines, with values of 0.3-2 and 0.29-29.2 μg/L, respectively. In the same samples, the contents of melatonin (MEL), serotonin (SER), 5-hydroxytryptophan (5-OHTRP), 5-hydroxyindole-3-acetic acid (5OHIA), and 5-methoxy-3-indoleacetic acid (5MIA) were all below the corresponding limits of detection.
Solid phase microextraction applied to the analysis of organophosphorus insecticides in fruits.
Fytianos, K; Raikos, N; Theodoridis, G; Velinova, Z; Tsoukali, H
2006-12-01
Trace amounts of organophosphorus pesticides (OPs) were determined in various fruits by headspace solid phase microextraction (HS-SPME) and gas chromatography-nitrogen phosphorous detection (GC-NPD). Sampling from the headspace enhanced method selectivity, whereas at the same time improved fiber life time and method sensitivity. Diazinon, parathion, methyl parathion, malathion and fenithrothion were determined in various fruits: more than 150 samples of 21 types of fruits were studied. SPME-GC-NPD provided a useful and very efficient analytical tool: method linearity ranged from 1.2 to 700 ng/ml. Limits of detection (LODs) and quantitation (LOQs) ranged from 0.03 to 3 ng/ml and 0.12 to 10 ng/ml respectively, values well below the residue limits set by the EU. Less than 2% of the samples were found positive containing amounts higher than the EU limits. The effect of fruit peeling and washing was also investigated.
Christenson, Robert H; Mullins, Kristin; Duh, Show-Hong
2018-06-01
High-Sensitivity (hs) cardiac troponin (cTn) assays are categorized by two criteria: (i) cTn values above the limit of detection (LoD) for >50% of male and female healthy cohorts of ≥300 individuals; (ii) imprecision ≤10% total %CV for sex-specific 99th-percentile clinical decision values (CDVs). No documented hs-Tn assay has yet been FDA-cleared. The PATHFAST cTnI-II assay's LoD was 2.3 ng/L using CLSI EP-17. The AACC Universal Sample Bank of 847 healthy men (50.6%) and women (49.4%) was used to determine 99th-percentile CDVs with Nonparametric, Harrell-Davis and Robust modeling. Health/Medication questionnaires and Amino-terminal proBNP, Hemoglobin A 1c and estimated Glomerular Filtration Rate surrogates excluded underlying health conditions. The cTnI-II test's total CV was 6.1% at 29 ng/L and 7.1% at 22 ng/L; the LoD was 2.3 ng/L. Of the full 847-member healthy cohort, 113 (13.3%) were excluded by abnormal surrogate biomarkers. The final 734-member healthy population had the following (% > LoD): overall, 487 (66.3%); women, 186 (52.8%); and men, 301 (78.8%). 99th-percentile CDVs by Nonparametric modeling were: 28 ng/L (90% CI: 20-30), overall final 732-member healthy population; 20 ng/L (90% CI: 13-30), 352 women; and 30 ng/L (90% CI: 21-37), 382 men. Differences between sex-specific CDVs were not significantly different (p > .05) with Nonparametric or Harrell-Davis modeling; however, Robust Modeling did show significance (<0.05), with lower CDVs at 11 ng/L (90% CI: 9-12) and 16 ng/L (90% CI: 15-18) for the female and male cohorts, respectively. cTnI-II is the only FDA-cleared assay that has demonstrated high-sensitivity cTn assay. Use of recommended modeling in >300 healthy subjects for determining sex-specific 99th-percentile CDVs did not show statistically significant differences except with the Robust modeling. Copyright © 2018. Published by Elsevier Inc.
Mid-pregnancy circulating immune biomarkers in women with preeclampsia and normotensive controls.
Taylor, Brandie D; Tang, Gong; Ness, Roberta B; Olsen, Jørn; Hougaard, David M; Skogstrand, Kristin; Roberts, James M; Haggerty, Catherine L
2016-01-01
To determine if mid-pregnancy circulating immune biomarkers are associated with preeclampsia. Nested case-control study of 410 preeclamptic women and 297 normotensive controls with primiparous singleton pregnancies enrolled in the Danish National Birth Cohort. The mean gestational age in our cohort is 16 weeks (range 9-26). Preeclampsia was defined by blood pressure ⩾140/90 mmHg and proteinuria ⩾3 g/24 h. Serum immune biomarkers included interleukin (IL)-6, IL-6 receptor, IL-4, IL-4 receptor, IL-5, IL-12, IL-2, TNF-α, TNF-β, TNF-receptor, IL-1β, IL-1α, IL-8, IL-10, IFN-γ, IL-18, macrophage migration inhibitory factor, macrophage inflammatory protein, transforming growth factor-beta (TGF-β), and RANTES. Associations with preeclampsia, term preeclampsia and preterm preeclampsia were determined using two logistic regression models; (1) biomarkers were dichotomized by the limit of detection (LOD); (2) on the continuous scale, non-detectable values were imputed by LOD/2 and transformed (base 2). All models were adjusted for body mass index and smoking. IL1β was significantly associated with a decrease in the log odds of preeclampsia (p=0.0065), term preeclampsia (p=0.0230) and preterm preeclampsia (p=0.0068). Results were similar for IL4r and preeclampsia (p=0.0383). In the dichotomized models, detectable TNF-β was significantly associated with preeclampsia (ORadj 1.6, 95% CI 1.1-2.3) and term preeclampsia (OR 1.7, 95% CI 1.1-2.5) but not preterm preeclampsia. Detectable IL6 was significantly with term preeclampsia only (OR 1.5, 95% CI 1.1-2.2). Mid-pregnancy circulating IL1β, IL4r, IL6, and TNFβ were associated with preeclampsia. However, results were not consistent across statistical models. As the relationship is complex, future studies should explore cytokine clusters in preeclampsia risk. Copyright © 2015 International Society for the Study of Hypertension in Pregnancy. Published by Elsevier B.V. All rights reserved.
Abbasi, Naeem Akhtar; Malik, Riffat Naseem; Frantz, Adrien; Jaspers, Veerle Leontina Bernard
2016-01-15
The release of harmful chemicals in the Asian environment has recently increased dramatically due to rising industrial and agricultural activities. About 60% of the global human population is currently living on the Asian continent and may thus be exposed to a large range of different chemicals. Different classes of organohalogen chemicals have indeed been reported in various environmental compartments from Asia including humans and wildlife, but this issue has received less attention in birds. In this article, we reviewed the available literature on levels of legacy persistent organic pollutants (POPs) and various flame retardants (FRs) in Asian avifauna to analyze the existing pool of knowledge as well as to identify the gaps that should be addressed in future research. Furthermore, we discussed the variation in levels of organohalogens based on differences in regions, trophic level, dietary sources and migratory behaviors of species including distribution patterns in different tissues of birds. Although the mass of published literature is very low and even absent in many important regions of Asia, we deduced from the reported studies that levels of almost all classes of organohalogens (OHCs) including FRs were highest in East Asian countries such as Japan, China and South Korea, except for HCHs that were found at maximum levels in birds of South India. Concentrations (ng/g LW) of different OHCs in Asian birds ranged between
Effect of genomic drift of influenza PCR tests.
Stellrecht, Kathleen A; Nattanmai, Seela M; Butt, Jumshan; Maceira, Vincente P; Espino, Alvin A; Castro, Allan J; Landes, Allen; Dresser, Nicolas; Butt, Shafiq A
2017-08-01
Nucleic acid amplification assays have become the method of choice for influenza (Flu) testing due to superior accuracy and faster turnaround time. Although assays are designed to detect highly conserved genomic targets, mutations can influence test sensitivity. Most of the circulating viruses in the United States during the 2014-2015 season were associated with significant genetic drift; however, the effect on testing was unknown. We compared the performance of Prodesse ProFlu+/ProFAST+ (PFlu/PFAST), FilmArray Respiratory Panel (RP), cobas ® Influenza A/B test (cIAB), and Xpert ® Flu (Xpt) in a retrospective analysis of consecutive nasopharyngeal specimens received for a two-week period during the winter of 2015. Furthermore, limits of detection (LOD) were determined with six isolates of Flu. Of the 275 specimens, 63 were positive for FluA by PFAST, 60 were positive by RP, 58 were positive by cIAB and 52 were positive by Xpt. Only a subset of 135 specimens was tested by PFlu, of which 32 were positive. The sensitivity/specificity for PFAST, RP, cIAB, Xpt and PFlu was 100/99.1%, 96.7/99.5%, 91.8/99.1%, 85.2%/100%, and 75.6%/98.9%, respectively. LOD analyses demonstrated assay performance variations were strain associated. Specifically, PFlu's and cIAB's LODs were higher with A/Texas/50/2012-like and A/Switzerland/9715293/2013-like strains, while Xpt's highest LOD was with the Swiss strain. Strain-associated assay performance variation is known to occur with other Flu test methods; hence, it is not surprising that such variation would be observed with molecular tests. Careful monitoring and reporting for strain-associated variances are warranted for all test methods. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Hu, Li; Zhao, Nanjing; Liu, Wenqing; Meng, Deshuo; Fang, Li; Wang, Yin; Yu, Yang; Ma, Mingjun
2015-08-01
Heavy metals in water can be deposited on graphite flakes, which can be used as an enrichment method for laser-induced breakdown spectroscopy (LIBS) and is studied in this paper. The graphite samples were prepared with an automatic device, which was composed of a loading and unloading module, a quantitatively adding solution module, a rapid heating and drying module and a precise rotating module. The experimental results showed that the sample preparation methods had no significant effect on sample distribution and the LIBS signal accumulated in 20 pulses was stable and repeatable. With an increasing amount of the sample solution on the graphite flake, the peak intensity at Cu I 324.75 nm accorded with the exponential function with a correlation coefficient of 0.9963 and the background intensity remained unchanged. The limit of detection (LOD) was calculated through linear fitting of the peak intensity versus the concentration. The LOD decreased rapidly with an increasing amount of sample solution until the amount exceeded 20 mL and the correlation coefficient of exponential function fitting was 0.991. The LOD of Pb, Ni, Cd, Cr and Zn after evaporating different amounts of sample solution on the graphite flakes was measured and the variation tendency of their LOD with sample solution amounts was similar to the tendency for Cu. The experimental data and conclusions could provide a reference for automatic sample preparation and heavy metal in situ detection. supported by National Natural Science Foundation of China (No. 60908018), National High Technology Research and Development Program of China (No. 2013AA065502) and Anhui Province Outstanding Youth Science Fund of China (No. 1108085J19)
Mishandling and exposure of farm workers in Qatar to organophosphate pesticides.
Shomar, Basem; Al-Saad, Khalid; Nriagu, Jerome
2014-08-01
We used a combination of subjective (questionnaire) and objective (urinary metabolites) measurements to evaluate factors that can predict the exposure of farm workers in Qatar to organophosphate pesticides and to assess whether the levels of exposure are associated with any self-reported health outcomes. The results show that pesticides were being extensively mishandled in the farms. Very few (<2%) of the farm workers knew the names of the pesticide they were using, and about one-third of the participants did not know the amount of pesticides to be applied to the crops. Nearly all (96%) of the participants had participated in mixing pesticides together before use and few (29%) used protective clothing while engaged in this operation. A significant number of participants (18%) had no knowledge that pesticides are a health hazard. At least one dialkyllphosphate (DAP) metabolite was detected in every worker. The geometric mean (GM) concentration of the dimethylalkylphosphates (DMAP) was 108 nM (range, from below the limit of detection (LOD) to 351 nM), and the GM for the diethylalkylphosphates (DEAP) was 43 nM (range, LOD-180 nM). The GM for total concentration of the metabolites (DAP) of 146 nM (maximum value estimated to be 531 nM) is below the values that have been reported for farmers in some countries, but higher than the levels in the general populations of many countries. We explored the influence of metal exposure and found consistent and negative relationships between the DAP metabolites and the concentrations of most of the trace elements in the urine of the farm workers; the negative associations were statistically significant for Cr, Mn, Fe, Ni, As, and Pb. We suspect that the negative associations are not source-dependent but may be reflective of antagonistic relationships in human metabolism of OPPs and trace metals; hence we recommend that metals should be included as co-factors in assessing the health effects of OPP exposure. Copyright © 2014 Elsevier Inc. All rights reserved.
Vieira, F P; Mesquita, T L; Lara, P C P; Ramaldes, G A; Beinner, M A; Silva, J B B; Oliveira, M C; Silveira, J N
2013-10-01
In this work, stability and the pH-sensitivity of pH-sensitive stealth liposomes containing cisplatin exposed to plasma medium and their subsequent responses to pH modifications were evaluated. A method to determine platin in mouse plasma by electrothermal atomic absorption spectroscopy (ET AAS) was developed and validated. At first, a comparative study of sample preparation treatments with basic, acidic, and acidic added with Triton X-100 as a modifier was done. The best treatment was obtained with HCl 3% (v/v). The ET AAS method with acid treatment presented linearity at a range of 10-160 ng Pt/mL. The limits of detection (LOD) was 3.1 ng/mL Pt for acid treatment, while the limit quantification (LOQ) was 10 ng/mL Pt. The acid treatment presented good repeatability (VC<15.0%) and recovery close to 100%. This treatment was chosen for subsequent studies due to its best value of repeatability, recovery, LOD and lowest cost. pH-sensitive stealth liposomes, containing cisplatin, demonstrated low stability and poor response to pH variation after plasma incubation. These findings suggest that further studies are needed to improve liposome formulation i.e., to reduce its size. Copyright © 2013 Elsevier B.V. All rights reserved.
Do, Van-Khoai; Yamamoto, Masahiko; Taguchi, Shigeo; Takamura, Yuzuru; Surugaya, Naoki; Kuno, Takehiko
2018-06-01
A sensitive analytical method for determination of total cesium (Cs) in highly active liquid waste (HALW) by using modified liquid electrode plasma optical emission spectrometry (LEP-OES) is developed in this study. The instrument is modified to measure radioactive samples in a glove box. The effects of important factors, including pulsed voltage sequence and nitric acid concentration, on the emission of Cs are investigated. The limit of detection (LOD) and limit of quantification (LOQ) are 0.005 mg/L and 0.02 mg/L, respectively. The achieved LOD is one order lower than that of recently developed spectroscopic methods using liquid discharge plasma. The developed method is validated by subjecting a simulated HALW sample to inductively coupled plasma mass spectrometry (ICP-MS). The recoveries obtained from a spike-and-recovery test are 96-102%, implying good accuracy. The method is successfully applied to the quantification of Cs in a real HALW sample at the Tokai reprocessing plant in Japan. Apart from dilution and filtration of the HALW sample, no other pre-treatment process is required. The results agree well with the values obtained using gamma spectrometry. The developed method offers a reliable technique for rapid analysis of total Cs in HALW samples. Copyright © 2018 Elsevier B.V. All rights reserved.
Li, Cui; Zhang, Yaoyao; Eremin, Sergei A; Yakup, Omar; Yao, Gang; Zhang, Xiaoying
2017-07-15
Our aim in this study is to show that IgY antibody based immunoassays could be used to detect antibiotic residues in animal-derived food. Briefly, full antigens of gentamicin (Gent) and kanamycin (Kana) were used to immunize the laying chickens to prepare IgY antibodies. Then, these antibodies were evaluated by FPIA and ic-ELISA to detect Gent/Kana in animal-derived samples. The IC 50 of FPIA and ic-ELISA based anti-Gent IgY were 7.70±0.6μg/mL and 0.32±0.06μg/mL, respectively. The IC 50 of FPIA and ic-ELISA based anti-Kana IgY were 7.97±0.9μg/mL and 0.15±0.01μg/mL. The limits of detection (LOD, IC 10 ) for FPIA based anti-Gent/Kana IgY were 0.17 and 0.007μg/mL, respectively. The LOD for ic-ELISA were both 0.001μg/mL. These results indicated that the ic-ELISA might more suitable for antibiotic residues detection than FPIA. Copyright © 2017 Elsevier Ltd. All rights reserved.
Suherman, Alex L; Ngamchuea, Kamonwad; Tanner, Eden E L; Sokolov, Stanislav V; Holter, Jennifer; Young, Neil P; Compton, Richard G
2017-07-05
Ultratrace levels of Hg 2+ have been quantified by undertaking linear sweep voltammetry with a silver nanoparticle-modified glassy carbon electrode (AgNP-GCE) in aqueous solutions containing Hg 2+ . This is achieved by monitoring the change in the silver stripping peak with Hg 2+ concentration resulting from the galvanic displacement of silver by mercury: Ag(np) + 1/2Hg 2+ (aq) → Ag + (aq) + 1/2Hg(l). This facile and reproducible detection method exhibits an excellent linear dynamic range of 100.0 pM to 10.0 nM Hg 2+ concentration with R 2 = 0.982. The limit of detection (LoD) based on 3σ is 28 pM Hg 2+ , while the lowest detectable level for quantification purposes is 100.0 pM. This method is appropriate for routine environmental monitoring and drinking water quality assessment since the guideline value set by the US Environmental Protection Agency (EPA) for inorganic mercury in drinking water is 0.002 mg L -1 (10 nM).
Ravelo-Pérez, Lidia M; Hernández-Borges, Javier; Herrera-Herrera, Antonio V; Rodríguez-Delgado, Miguel Angel
2009-12-01
Room temperature ionic liquids (RTILs) have been used as extraction solvents in dispersive liquid-liquid microextraction (DLLME) for the determination of eight multi-class pesticides (i.e. thiophanate-methyl, carbofuran, carbaryl, tebuconazole, iprodione, oxyfluorfen, hexythiazox, and fenazaquin) in table grapes and plums. The developed method involves the combination of DLLME and high-performance liquid chromatography with diode array detection. Samples were first homogenized and extracted with acetonitrile. After evaporation and reconstitution of the extract in water containing sodium chloride, a quick DLLME procedure that used the ionic liquid 1-hexyl-3-methylimidazolium hexafluorophosphate ([C(6)MIM][PF(6)]) and methanol was developed. The RTIL dissolved in a very small volume of acetonitrile was directed injected in the chromatographic system. The comparison between the calibration curves obtained from standards and from spiked sample extracts (matrix-matched calibration) showed the existence of a strong matrix effect for most of the analyzed pesticides. A recovery study was also developed with five consecutive extractions of the two types of fruits spiked at three concentration levels. Mean recovery values were in the range of 72-100% for table grapes and 66-105% for plum samples (except for thiophanate-methyl and carbofuran, which were 64-75% and 58-66%, respectively). Limits of detection (LODs) were in the range 0.651-5.44 microg/kg for table grapes and 0.902-6.33 microg/kg for plums, representing LODs below the maximum residue limits (MRLs) established by the European Union in these fruits. The potential of the method was demonstrated by analyzing 12 commercial fruit samples (six of each type).
Albermann, M E; Musshoff, F; Madea, B
2012-01-01
Ethyl glucuronide (EtG) and ethyl sulfate (EtS) are powerful markers for alcohol intake and abuse. Several analytical procedures for the quantification of EtG and EtG in serum and urine have been developed so far. Many of the published methods show limits of detections (LODs) or limits of quantifications (LOQs) for EtG in urine within the range of 0.1 mg/L or higher. Since this is the actual cutoff value for proving abstinence in Germany, problems may occur if urine samples are highly diluted. In this paper, the validation of a highly sensitive, fast and simple LC-MS-MS for the determination of EtG and EtS in urine is described. The calibration curves for EtG and EtS is linear over the whole range (0.025-2.0 mg/L). Very low detection limits can be achieved (LOD: EtG 0.005 mg/L, EtS 0.005 mg/L; and LOQ: EtG 0.019 mg/L, EtS 0.015 mg/L). All data for selectivity, precision and accuracy, recovery, as well as for the processed sample and the freeze/thaw stability, comply with the guidelines of the German Society of Toxicological and Forensic Chemistry. Strong matrix-related effects can be compensated for by using an internal standard. Finally, the applicability of the procedure is proven by analysis of 87 human urine samples and by successful participation in interlaboratory comparison tests. © The Author [2011]. Published by Oxford University Press. All rights reserved.
Prado, A H; Borges, M C; Eloy, J O; Peccinini, R G; Chorilli, M
2017-10-01
Cutaneous penetration is a critical factor in the use of sunscreen, as the compounds should not reach systemic circulation in order to avoid the induction of toxicity. The evaluation of the skin penetration and permeation of the UVB filter octyl methoxycinnamate (OMC) is essential for the development of a successful sunscreen formulation. Liquid-crystalline systems are innovative and potential carriers of OMC, which possess several advantages, including controlled release and protection of the filter from degradation. In this study, a new and effective method was developed using ultra-high performance liquid chromatography (UPLC) with ultraviolet detection (UV) for the quantitative analysis of penetration of OMC-loaded liquid crystalline systems into the skin. The following parameters were assessed in the method: selectivity, linearity, precision, accuracy, robustness, limit of detection (LOD), and limit of quantification (LOQ). The analytical curve was linear in the range from 0.25 to 250 μg.m-1, precise, with a standard deviation of 0.05-1.24%, with an accuracy in the range from 96.72 to 105.52%, and robust, with adequate values for the LOD and LOQ of 0.1 and 0.25 μg.mL -1, respectively. The method was successfully used to determine the in vitro skin permeation of OMC-loaded liquid crystalline systems. The results of the in vitro tests on Franz cells showed low cutaneous permeation and high retention of the OMC, particularly in the stratum corneum, owing to its high lipophilicity, which is desirable for a sunscreen formulation.
Piccinini, Esteban; Bliem, Christina; Reiner-Rozman, Ciril; Battaglini, Fernando; Azzaroni, Omar; Knoll, Wolfgang
2017-06-15
We present the construction of layer-by-layer (LbL) assemblies of polyethylenimine and urease onto reduced-graphene-oxide based field-effect transistors (rGO FETs) for the detection of urea. This versatile biosensor platform simultaneously exploits the pH dependency of liquid-gated graphene-based transistors and the change in the local pH produced by the catalyzed hydrolysis of urea. The use of an interdigitated microchannel resulted in transistors displaying low noise, high pH sensitivity (20.3µA/pH) and transconductance values up to 800 µS. The modification of rGO FETs with a weak polyelectrolyte improved the pH response because of its transducing properties by electrostatic gating effects. In the presence of urea, the urease-modified rGO FETs showed a shift in the Dirac point due to the change in the local pH close to the graphene surface. Markedly, these devices operated at very low voltages (less than 500mV) and were able to monitor urea in the range of 1-1000µm, with a limit of detection (LOD) down to 1µm, fast response and good long-term stability. The urea-response of the transistors was enhanced by increasing the number of bilayers due to the increment of the enzyme surface coverage onto the channel. Moreover, quantification of the heavy metal Cu 2+ (with a LOD down to 10nM) was performed in aqueous solution by taking advantage of the urease specific inhibition. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Wardani, Devy P.; Arifin, Muhammad; Suharyadi, Edi; Abraha, Kamsul
2015-05-01
Gelatin is a biopolymer derived from collagen that is widely used in food and pharmaceutical products. Due to some religion restrictions and health issues regarding the gelatin consumption which is extracted from certain species, it is necessary to establish a robust, reliable, sensitive and simple quantitative method to detect gelatin from different parent collagen species. To the best of our knowledge, there has not been a gelatin differentiation method based on optical sensor that could detect gelatin from different species quantitatively. Surface plasmon resonance (SPR) based biosensor is known to be a sensitive, simple and label free optical method for detecting biomaterials that is able to do quantitative detection. Therefore, we have utilized SPR-based biosensor to detect the differentiation between bovine and porcine gelatin in various concentration, from 0% to 10% (w/w). Here, we report the ability of SPR-based biosensor to detect difference between both gelatins, its sensitivity toward the gelatin concentration change, its reliability and limit of detection (LOD) and limit of quantification (LOQ) of the sensor. The sensor's LOD and LOQ towards bovine gelatin concentration are 0.38% and 1.26% (w/w), while towards porcine gelatin concentration are 0.66% and 2.20% (w/w), respectively. The results show that SPR-based biosensor is a promising tool for detecting gelatin from different raw materials quantitatively.
Timsit, J F; Fosse, J P; Troché, G; De Lassence, A; Alberti, C; Garrouste-Orgeas, M; Azoulay, E; Chevret, S; Moine, P; Cohen, Y
2001-06-01
In most databases used to build general severity scores the median duration of intensive care unit (ICU) stay is less than 3 days. Consequently, these scores are not the most appropriate tools for measuring prognosis in studies dealing with ICU patients hospitalized for more than 72 h. To develop a new prognostic model based on a general severity score (SAPS II), an organ dysfunction score (LOD) and evolution of both scores during the first 3 days of ICU stay. Prospective multicenter study. Twenty-eight intensive care units (ICUs) in France. A training data-set was created with four ICUs during an 18-month period (893 patients). Seventy percent of the patients were medical (628) aged 66 years. The median SAPS II was 38. The ICU and hospital mortality rates were 22.7% and 30%, respectively. Forty-seven percent (420 patients) were transferred from hospital wards. In this population, the calibration (Hosmer-Lemeshow chi-square: 37.4, P = 0.001) and the discrimination [area under the ROC curves: 0.744 (95 % CI: 0.714-0.773)] of the original SAPS II were relatively poor. A validation data set was created with a random panel of 24 French ICUs during March 1999 (312 patients). The LOD and SAPS II scores were calculated during the first (SAPS1, LOD1), second (SAPS2, LOD2), and third (SAPS3, LOD3) calendar days. The LOD and SAPS scores alterations were assigned the value "1" when scores increased with time and "0" otherwise. A multivariable logistic regression model was used to select variables measured during the first three calendar days, and independently associated with death. Selected variables were: SAPS II at admission [OR: 1.04 (95 % CI: 1.027-1.053) per point], LOD [OR: 1.16 (95 % CI: 1.085-1.253) per point], transfer from ward [OR: 1.74 (95 % CI: 1.25-2.42)], as well as SAPS3-SAPS2 alterations [OR: 1.516 (95 % CI: 1.04-2.22)], and LOD3-LOD2 alterations [OR: 2.00 (95 % CI: 1.29-3.11)]. The final model has good calibration and discrimination properties in the training data set [area under the ROC curve: 0.794 (95 % CI: 0.766-0.820), Hosmer-Lemeshow C statistic: 5.56, P = 0.7]. In the validation data set, the model maintained good accuracy [area under the ROC curve: 0.826 (95 % CI: 0.780-0.867), Hosmer-Lemeshow C statistic: 7.14, P = 0.5]. The new model using SAPS II and LOD and their evolution during the first calendar days has good discrimination and calibration properties. We propose its use for benchmarking and evaluating the over-risk of death associated with ICU-acquired nosocomial infections.
Sanchez-Prado, Lucia; Lamas, J Pablo; Lores, Marta; Garcia-Jares, Carmen; Llompart, Maria
2010-11-15
An effective one-step sample preparation methodology for the determination of multiclass preservatives in cosmetics has been developed, applying, for the first time to this kind of matrix, pressurized liquid extraction (PLE) and a very simple, cheap, and fast derivatization procedure: acetylation with acetic anhydride and pyridine. A multifactorial experimental design has been used to evaluate and optimize the main experimental parameters potentially affecting the extraction process. In the final conditions the sample was mixed with Florisil as the dispersing sorbent and extracted with ethyl acetate for 15 min at 120 °C. One of the main goals of this work was to demonstrate the possibility of carrying out direct cosmetic preservative acetylation by simply adding the derivatization reagents into the PLE cell. The extract was then analyzed by GC/MS without any further cleanup or concentration step. The accuracy, precision, linearity, and detection limits (LODs) were evaluated to assess the performance of the proposed method. Quantitative recoveries were obtained, and relative standard deviation values were lower than 10% in all cases. The obtained LODs ranged from 0.000004% to 0.0001% (w/w), values far below the established restrictions in the European Cosmetics Regulation, making this multicomponent analytical method suitable for routine control. Finally, several cosmetic products such as moisturizing and antiwrinkle creams and lotions, hand creams, sunscreen and after-sun creams, baby lotions, and hair care products were analyzed. All the samples contained several of the target cosmetic ingredients, in some cases at quite high concentrations, although the actual European Cosmetics Regulation was fulfilled in all cases.
Cha, Eunju; Kim, Sohee; Kim, Ho Jun; Lee, Kang Mi; Kim, Ki Hun; Kwon, Oh-Seung; Lee, Jaeick
2015-01-01
This study compared the sensitivity of various separation and ionization methods, including gas chromatography with an electron ionization source (GC-EI), liquid chromatography with an electrospray ionization source (LC-ESI), and liquid chromatography with a silver ion coordination ion spray source (LC-Ag(+) CIS), coupled to a mass spectrometer (MS) for steroid analysis. Chromatographic conditions, mass spectrometric transitions, and ion source parameters were optimized. The majority of steroids in GC-EI/MS/MS and LC-Ag(+) CIS/MS/MS analysis showed higher sensitivities than those obtained with other analytical methods. The limits of detection (LODs) of 65 steroids by GC-EI/MS/MS, 68 steroids by LC-Ag(+) CIS/MS/MS, 56 steroids by GC-EI/MS, 54 steroids by LC-ESI/MS/MS, and 27 steroids by GC-ESI/MS/MS were below cut-off value of 2.0 ng/mL. LODs of steroids that formed protonated ions in LC-ESI/MS/MS analysis were all lower than the cut-off value. Several steroids such as unconjugated C3-hydroxyl with C17-hydroxyl structure showed higher sensitivities in GC-EI/MS/MS analysis relative to those obtained using the LC-based methods. The steroids containing 4, 9, 11-triene structures showed relatively poor sensitivities in GC-EI/MS and GC-ESI/MS/MS analysis. The results of this study provide information that may be useful for selecting suitable analytical methods for confirmatory analysis of steroids. Copyright © 2015 John Wiley & Sons, Ltd.
NASA Astrophysics Data System (ADS)
Raghu, M. S.; Basavaiah, K.; Ramesh, P. J.; Abdulrahman, Sameer A. M.; Vinay, K. B.
2012-03-01
A sensitive, precise, and cost-effective UV-spectrophotometric method is described for the determination of pheniramine maleate (PAM) in bulk drug and tablets. The method is based on the measurement of absorbance of a PAM solution in 0.1 N HCl at 264 nm. As per the International Conference on Harmonization (ICH) guidelines, the method was validated for linearity, accuracy, precision, limits of detection (LOD) and quantification (LOQ), and robustness and ruggedness. A linear relationship between absorbance and concentration of PAM in the range of 2-40 μg/ml with a correlation coefficient (r) of 0.9998 was obtained. The LOD and LOQ values were found to be 0.18 and 0.39 μg/ml PAM, respectively. The precision of the method was satisfactory: the value of relative standard deviation (RSD) did not exceed 3.47%. The proposed method was applied successfully to the determination of PAM in tablets with good accuracy and precision. Percentages of the label claims ranged from 101.8 to 102.01% with the standard deviation (SD) from 0.64 to 0.72%. The accuracy of the method was further ascertained by recovery studies via a standard addition procedure. In addition, the forced degradation of PAM was conducted in accordance with the ICH guidelines. Acidic and basic hydrolysis, thermal stress, peroxide, and photolytic degradation were used to assess the stability-indicating power of the method. A substantial degradation was observed during oxidative and alkaline degradations. No degradation was observed under other stress conditions.
Intrinsic low pass filtering improves signal-to-noise ratio in critical-point flexure biosensors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jain, Ankit; Alam, Muhammad Ashraful, E-mail: alam@purdue.edu
2014-08-25
A flexure biosensor consists of a suspended beam and a fixed bottom electrode. The adsorption of the target biomolecules on the beam changes its stiffness and results in change of beam's deflection. It is now well established that the sensitivity of sensor is maximized close to the pull-in instability point, where effective stiffness of the beam vanishes. The question: “Do the signal-to-noise ratio (SNR) and the limit-of-detection (LOD) also improve close to the instability point?”, however remains unanswered. In this article, we systematically analyze the noise response to evaluate SNR and establish LOD of critical-point flexure sensors. We find thatmore » a flexure sensor acts like an effective low pass filter close to the instability point due to its relatively small resonance frequency, and rejects high frequency noise, leading to improved SNR and LOD. We believe that our conclusions should establish the uniqueness and the technological relevance of critical-point biosensors.« less
NASA Technical Reports Server (NTRS)
Taylor, H. A., Jr.; Mayr, H. G.; Kramer, L.
1985-01-01
For many years it has been recognized that recurrent modulations occur in the time series of the earth's rotation rate or, alternatively, the change in the length of the day (Delta-LOD). Studies relating Delta-LOD to global patterns of zonal winds have confirmed that the variability of atmospheric angular momentum (M) is of sufficient magnitude to account for a large portion of the gross periodicities observed in the earth rotation. The present investigation is concerned with the importance of the contributions of the moment of inertia and high-altitude winds to the angular momentum budget. On the basis of an analysis of the various factors, it is found that within the available data, contributions of high-altitude winds and atmospheric moment of inertia reach levels detectable in the atmospheric angular momentum budget. Nevertheless, for the period December 1978 to December 1979 these contributions are not sufficient to resolve the apparent short-term discrepancies which are evident between Delta-LOD and M.
Durakli Velioglu, Serap; Ercioglu, Elif; Boyaci, Ismail Hakki
2017-05-01
This research paper describes the potential of synchronous fluorescence (SF) spectroscopy for authentication of buffalo milk, a favourable raw material in the production of some premium dairy products. Buffalo milk is subjected to fraudulent activities like many other high priced foodstuffs. The current methods widely used for the detection of adulteration of buffalo milk have various disadvantages making them unattractive for routine analysis. Thus, the aim of the present study was to assess the potential of SF spectroscopy in combination with multivariate methods for rapid discrimination between buffalo and cow milk and detection of the adulteration of buffalo milk with cow milk. SF spectra of cow and buffalo milk samples were recorded between 400-550 nm excitation range with Δλ of 10-100 nm, in steps of 10 nm. The data obtained for ∆λ = 10 nm were utilised to classify the samples using principal component analysis (PCA), and detect the adulteration level of buffalo milk with cow milk using partial least square (PLS) methods. Successful discrimination of samples and detection of adulteration of buffalo milk with limit of detection value (LOD) of 6% are achieved with the models having root mean square error of calibration (RMSEC) and the root mean square error of cross-validation (RMSECV) and root mean square error of prediction (RMSEP) values of 2, 7, and 4%, respectively. The results reveal the potential of SF spectroscopy for rapid authentication of buffalo milk.
LOD map--A visual interface for navigating multiresolution volume visualization.
Wang, Chaoli; Shen, Han-Wei
2006-01-01
In multiresolution volume visualization, a visual representation of level-of-detail (LOD) quality is important for us to examine, compare, and validate different LOD selection algorithms. While traditional methods rely on ultimate images for quality measurement, we introduce the LOD map--an alternative representation of LOD quality and a visual interface for navigating multiresolution data exploration. Our measure for LOD quality is based on the formulation of entropy from information theory. The measure takes into account the distortion and contribution of multiresolution data blocks. A LOD map is generated through the mapping of key LOD ingredients to a treemap representation. The ordered treemap layout is used for relative stable update of the LOD map when the view or LOD changes. This visual interface not only indicates the quality of LODs in an intuitive way, but also provides immediate suggestions for possible LOD improvement through visually-striking features. It also allows us to compare different views and perform rendering budget control. A set of interactive techniques is proposed to make the LOD adjustment a simple and easy task. We demonstrate the effectiveness and efficiency of our approach on large scientific and medical data sets.
Occurrence of deoxynivalenol in wheat flour, instant noodle and biscuits commercialised in Brazil.
Almeida, Adriana Palma de; Lamardo, Leda Conceição Antonia; Shundo, Luzia; Silva, Simone Alves da; Navas, Sandra Aparecida; Alaburda, Janete; Ruvieri, Valter; Sabino, Myrna
2016-12-01
A total of 134 samples, consisting of 58 wheat flour, 40 instant noodle and 36 biscuits, were analysed for the presence of deoxynivalenol (DON). The samples were obtained from retail markets of the city of São Paulo during the period 2010-2014. DON was determined by high performance liquid chromatography with ultraviolet detection and immunoaffinity sample clean-up. Method validation followed international guidelines. The LOD and LOQ were 60 and 200 µg kg -1 , respectively, considering the three different types of samples analysed. The lowest recovery found in this study was 91.8% with RSD 4.5% for instant noodles. DON was detected in 91.4%, 97.5% and 97.2% of samples wheat flour, instant noodles and biscuits, respectively, resulting in a total of 94.8% with levels ranging from LOD to 1720.0 µg kg -1 .
Enzymatic amplification of a flow-injected thermometric enzyme-linked immunoassay for human insulin.
Mecklenburg, M; Lindbladh, C; Li, H; Mosbach, K; Danielsson, B
1993-08-01
A flow-injected thermometric enzyme linked immunoassay for human insulin which employs the lactate dehydrogenase/lactate oxidase (LDH/LOD) substrate recycling system for signal amplification is described. The system is composed of two columns, an immunosorbent column containing immobilized anti-insulin antibodies for sensing and a recycling column containing immobilized LDH/LOD/Catalase for detection. The effect of flow rates, conjugate concentrations, and chromatographic support material upon the sensitivity of the assay are investigated. The assay has a detection limit of 0.025 microgram/ml and a linear range from 0.05 to 2 micrograms/ml. This corresponds to a 10-fold increase in sensitivity over the unamplified system. A recombinant human insulin-proinsulin conjugate was also tested. The results show that enzymatic amplification can be employed to increase the sensitivity and reproducibility of flow injection assay-based biosensors. The implications of these results upon on-line analysis are discussed.
An aptamer-based paper microfluidic device for the colorimetric determination of cocaine.
Wang, Ling; Musile, Giacomo; McCord, Bruce R
2018-02-01
A method utilizing paper microfluidics coupled with gold nanoparticles and two anticocaine aptamers has been developed to detect seized cocaine samples. The ready-to-use format involves the use of a paper strip that produces a color change resulting from the salt-induced aggregation of gold nanoparticles producing a visible color change indicating the presence of the drug. This format is specific for the detection of cocaine. The visual LOD for the method was 2.5 μg and the camera based LOD was 2.36 μg. The operation of the device is easy and rapid, and does not require extensive training or instrumentation. All of the materials utilized in the device are safe and environmental friendly. This device should prove a useful tool for the screening of forensic samples. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Chen, Xiaochun; Yu, Shaoming; Yang, Liang; Wang, Jianping; Jiang, Changlong
2016-07-14
The instant and on-site detection of trace aqueous fluoride ions is still a challenge for environmental monitoring and protection. This work demonstrates a new analytical method and its utility of a paper sensor for visual detection of F(-) on the basis of the fluorescence resonance energy transfer (FRET) between photoluminescent graphene oxide (GO) and silver nanoparticles (AgNPs) through the formation of cyclic esters between phenylborinic acid and diol. The fluorescence of GO was quenched by the AgNPs, and trace F(-) can recover the fluorescence of the quenched photoluminescent GO. The increase in fluorescence intensity is proportional to the concentration of F(-) in the range of 0.05-0.55 nM, along with a limit of detection (LOD) as low as 9.07 pM. Following the sensing mechanism, a paper-based sensor for the visual detection of aqueous F(-) has been successfully developed. The paper sensor showed high sensitivity for aqueous F(-), and the LOD could reach as low as 0.1 μM as observed by the naked eye. The very simple and effective strategy reported here could be extended to the visual detection of a wide range of analytes in the environment by the construction of highly efficient FRET nanoprobes.
Enhanced Laser-Induced Breakdown Spectroscopy By Second-Pulse Selective Wavelength Excitation
NASA Astrophysics Data System (ADS)
Vidal, F.; Chaker, M.; Goueguel, C.; Laville, S.; Loudyi, H.; Rifai, K.; Sabsabi, M.
2008-09-01
We investigate the use of a second laser with a selected wavelength to improve the limit of detection (LoD) of trace elements in the Laser-Induced Breakdown Spectroscopy (LIBS) technique. We consider the combination of LIBS with Laser-Induced Fluorescence (LIF), in which the second laser is used to excite trace elements in the plasma. The influence of the main experimental parameters on the trace elements LIF signal, namely the ablation fluence, the excitation energy, and the inter-pulse delay, was studied experimentally and a physical interpretation of the results was presented. For illustrative purpose we considered detection of Pb in brass samples and in water. The plasma was produced by a Q-switched Nd:YAG laser and then re-excited by a nanosecond optical parametric oscillator laser. We found out that the optimal conditions for our experimental set-up were obtained for relatively weak ablation fluence of 2-3 J/cm2 and inter-pulse delay of 5-10 μs. Using the LIBS-LIFS technique, a single-shot LoD for detection of lead of about 1.5 part per million (ppm) was obtained for solids and 0.5 ppm for liquids. These LoDs represent an improvement of about two orders of magnitude with respect to LIBS. We also discuss resonance-enhanced LIBS (RELIBS), in which the second laser excites the main plasma component instead of the impurities. For the set of parameters used the RELIBS, Pb signal does not differ significantly from the LIBS signal except at low ablation fluence.
Font, Eva; Rosario, Osvaldo; Santana, Jorge; García, Hermes; Sommadossi, Jean-Pierre; Rodriguez, Jose F.
1999-01-01
Nucleoside reverse transcriptase inhibitors (NRTIs) used against the human immunodeficiency virus (HIV) need to be activated intracellularly to their triphosphate moiety to inhibit HIV replication. Intracellular concentrations of these NRTI triphosphates, especially zidovudine triphosphate (ZDV-TP), are relatively low (low numbers of femtomoles per 106 cells) in HIV-infected patient peripheral blood mononuclear cells. Recently, several methods have used either high-performance liquid chromatography (HPLC) or solid-phase extraction (SPE) coupled with radioimmunoassay to obtain in vivo measurements of ZDV-TP. The limit of detection (LOD) by these methods ranged from 20 to 200 fmol/106 cells. In this report, we describe the development of a method to determine intracellular ZDV-TP concentrations in HIV-infected patients using SPE and HPLC with tandem mass spectrometry for analysis. The LOD by this method is 4.0 fmol/106 cells with a linear concentration range of at least 4 orders of magnitude from 4.0 to 10,000 fmol/106 cells. In hispanic HIV-infected patients, ZDV-TP was detectable even when the sampling time after drug administration was 15 h. Intracellular ZDV-TP concentrations in these patients ranged from 41 to 193 fmol/106 cells. The low LOD obtained with this method will provide the opportunity for further in vivo pharmacokinetic studies of intracellular ZDV-TP in different HIV-infected populations. Furthermore, this methodology could be used to perform simultaneous detection of two or more NRTIs, such as ZDV-TP and lamivudine triphosphate. PMID:10582890
Liu, Yan-Ming; Cao, Jun-Tao; Zheng, Yan-Li; Chen, Yong-Hong
2008-07-01
A new and sensitive method for the determination of norepinephrine (NE), synephrine, and isoproterenol was developed by CE separation and indirect electrochemiluminescence detection (ECL) based on their quenching effects on the tris(2,2'-bipyridyl)-ruthenium(II)/tripropylamine (TPA) system. The conditions for CE separation and ECL detection were investigated in detail. Under the optimum conditions, the three analytes were well separated within 9 min. The LODs (S/N = 3) in standard solution are 2.6 x 10(-8) mol/L for NE, 6.6 x 10(-9) mol/L for synephrine and 8.4 x 10(-8) mol/L for isoproterenol, respectively. The precisions of intraday and interday are less than 4.4 and 6.1%, respectively. The LOQs (S/N = 10) in real human urine samples are 2.6 x 10(-7) mol/L for NE, 8.8 x 10(-8 ) mol/L for synephrine, and 8.8 x 10(-7) mol/L for isoproterenol, respectively. The applicability of the proposed method was illustrated in the determination of 20 human urine samples from diabetic patients and healthy persons. The results obtained indicated that the level of NE in patients (mean value 0.41 micromol/L) was higher than that in healthy persons (mean value 0.24 micromol/L).
NASA Astrophysics Data System (ADS)
Demetrescu, C.; Dobrica, V.; Stefan, C.
2017-12-01
A rich scientific literature is linking length-of-day (LOD) fluctuations to geomagnetic field and flow oscillations in the fluid outer core. We demostrate that the temporal evolution of the geomagnetic field shows the existence of several oscillations at decadal, inter-decadal, and sub-centennial time scales that superimpose on a so-called inter-centennial constituent. We show that while the subcentennial oscillations of the geomagnetic field, produced by torsional oscillations in the core, could be linked to oscillations of LOD at a similar time scale, the oscillations at decadal and sub-decadal time scales, of external origin, can be found in LOD too. We discuss these issues from the perspective of long time-span main field models (gufm1 - Jackson et al., 2000; COV-OBS - Gillet et al., 2013) that are used to retrieve time series of geomagnetic elements in a 2.5x2.5° network. The decadal and sub-decadal constituents of the time series of annual values in LOD and geomagnetic field were separated in the cyclic component of a Hodrick-Prescott filtering applied to data, and shown to highly correlate to variations of external sources such as the magnetospheric ring current.
Padró, J M; Osorio-Grisales, J; Arancibia, J A; Olivieri, A C; Castells, C B
2016-10-07
In this work, we studied the combination of chemometric methods with chromatographic separations as a strategy applied to the analysis of enantiomers when complete enantioseparation is difficult or requires long analysis times and, in addition, the target signals have interference from the matrix. We present the determination of ibuprofen enantiomers in pharmaceutical formulations containing homatropine as interference by chiral HPLC-DAD detection in combination with partial least-squares algorithms. The method has been applied to samples containing enantiomeric ratios from 95:5 to 99.5:0.5 and coelution of interferents. The results were validated using univariate calibration and without homatropine. Relative error of the method was less than 4.0%, for both enantiomers. Limits of detection (LOD) and quantification (LOQ) for (S)-(+)-ibuprofen were 4.96×10 -10 and 1.50×10 -9 mol, respectively. LOD and LOQ for the R-(-)-ibuprofen were LOD=1.60×10 -11 mol and LOQ=4.85×10 -11 mol, respectively. Finally, the chemometric method was applied to the determination of enantiomeric purity of commercial pharmaceuticals. The ultimate goal of this research was the development of rapid, reliable, and robust methods for assessing enantiomeric purity by conventional diode array detector assisted by chemometric tools. Copyright © 2016 Elsevier B.V. All rights reserved.
Hormonal Changes After Laparoscopic Ovarian Diathermy in Patients with Polycystic Ovarian Syndrome.
Elnaggar, Elsayed A; Elwan, Youssef Abo; Ibrahim, Safaa A; Abdalla, Mena M
2016-10-01
To assess the changes in hormonal profile (serum FSH, LH, prolactin and total testosterone) following laparoscopic ovarian drilling (LOD) in patients with polycystic ovarian syndrome. Fifty patients with PCOS have been included in this study. Serum prolactin, total testosterone, follicular-stimulating hormone (FSH) and luteinizing hormone (LH) levels have been used as biochemical markers, before and after procedures. Laparoscopic ovarian drilling was successfully employed without any surgical complications and on an average follow-up time of 24 weeks after the procedure. During the follow-up serum values for prolactin, total testosterone and LH have decreased significantly and FSH levels remained unchanged after the procedure. The LOD in patients with PCOS may avoid or reduce the risk of OHSS and the multiple pregnancy rate induced by gonadotropin therapy. The high pregnancy rate and the economic aspect of the procedure offer an attractive management for patients with PCOS. However, LOD can be considered as second-line treatment after clomiphene citrate treatment failure and/or resistance.
Raboud, J M; Rae, S; Hogg, R S; Yip, B; Sherlock, C H; Harrigan, P R; O'Shaughnessy, M V; Montaner, J S
1999-10-01
Suppression of human immunodeficiency virus type 1 plasma virus load (PVL) to <20 copies/mL is associated with a longer virologic response after initiation of antiretroviral therapy. The relationship between duration of virologic response and PVL nadir according to a less sensitive assay was explored. When compared with subjects with a PVL nadir >500 copies/mL, the relative risks of PVL rising above 1000 copies/mL for participants in the INCAS trial and the British Columbia Drug Treatment Program with a PVL nadir below the limit of detection (LOD) were 0.04 (95% confidence interval [CI], 0.02-0.09) and 0.06 (95% CI, 0.03-0.12), respectively. The corresponding relative risks for persons with a detectable but not quantifiable PVL nadir were 0.25 (95% CI, 0.13-0.50) and 0.54 (95% CI, 0.25-1.19). The relative risks of virologic failure associated with a PVL nadir detectable but not quantifiable and a PVL nadir below the LOD were statistically different (P<.0001) in both data sets.
Thanyasiriwat, T; Sraphet, S; Whankaew, S; Boonseng, O; Bao, J; Lightfoot, D A; Tangphatsornruang, S; Triwitayakorn, K
2014-01-01
Starch pasting viscosity is an important quality trait in cassava (Manihot esculenta Crantz) cultivars. The aim here was to identify loci and candidate genes associated with the starch pasting viscosity. Quantitative trait loci (QTL) mapping for seven pasting viscosity parameters was carried out using 100 lines of an F1 mapping population from a cross between two cassava cultivars Huay Bong 60 and Hanatee. Starch samples were obtained from roots of cassava grown in 2008 and 2009 at Rayong, and in 2009 at Lop Buri province, Thailand. The traits showed continuous distribution among the F1 progeny with transgressive variation. Fifteen QTL were identified from mean trait data, with Logarithm of Odds (LOD) values from 2.77-13.01 and phenotype variations explained (PVE) from10.0-48.4%. In addition, 48 QTL were identified in separate environments. The LOD values ranged from 2.55-8.68 and explained 6.6-43.7% of phenotype variation. The loci were located on 19 linkage groups. The most important QTL for pasting temperature (PT) (qPT.1LG1) from mean trait values showed largest effect with highest LOD value (13.01) and PVE (48.4%). The QTL co-localised with PT and pasting time (PTi) loci that were identified in separate environments. Candidate genes were identified within the QTL peak regions. However, the major genes of interest, encoding the family of glycosyl or glucosyl transferases and hydrolases, were located at the periphery of QTL peaks. The loci identified could be effectively applied in breeding programmes to improve cassava starch quality. Alleles of candidate genes should be further studied in order to better understand their effects on starch quality traits. © 2013 German Botanical Society and The Royal Botanical Society of the Netherlands.
NASA Astrophysics Data System (ADS)
Taghdisi, Seyed Mohammad; Danesh, Noor Mohammad; Beheshti, Hamed Reza; Ramezani, Mohammad; Abnous, Khalil
2016-02-01
Analytical approaches for the detection and quantitation of ochratoxin A (OTA) in blood serum and food products are high in demand. In this study, a fluorescent aptamer-based sensor (aptasensor) is developed for the selective and sensitive detection of OTA, based on a complementary strand of aptamer (CS) and two types of nanoparticles, gold nanoparticles (AuNPs) and silica nanoparticles (SNPs) coated with streptavidin. The fabricated aptasensor inherits the characteristics of SNPs, as enhancers of fluorescence intensity; AuNPs, such as large surface area and unique optical properties; and high affinity of the aptamer toward its target compared to its CS. In the absence of OTA, no FAM and biotin-labeled CS is in the environment of the SNPs coated with streptavidin, which leads to no fluorescence emission. In the presence of the target, an FAM and biotin-labeled CS-SNPs coated with streptavidin conjugate is formed, thus resulting in a very strong fluorescence emission. The designed fluorescent aptasensor exhibits high selectivity toward OTA with a limit of detection (LOD) as low as 0.098 nM. Furthermore, the fabricated aptasensor was successfully applied for the detection of OTA in grape juice and serum with LODs of 0.113 and 0.152 nM, respectively.
Huikko, K; Ostman, P; Sauber, C; Mandel, F; Grigoras, K; Franssila, S; Kotiaho, T; Kostiainen, R
2003-01-01
The feasibility of atmospheric pressure desorption/ionization on silicon mass spectrometry (AP-DIOS-MS) for drug analysis was investigated. It was observed that only compounds with relative high proton affinity are efficiently ionized under AP-DIOS conditions. The limits of detection (LODs) achieved in MS mode with midazolam, propranolol, and angiotensin II were 80 fmol, 20 pmol, and 1 pmol, respectively. In MS/MS mode the LODs for midazolam and propranolol were 10 fmol and 5 pmol, respectively. The good linearity (r(2) > 0.991), linear dynamic range of 3 orders of magnitude, and reasonable repeatability showed that the method is suitable for quantitative analysis. Copyright 2003 John Wiley & Sons, Ltd.
A genome-wide linkage study of mammographic density, a risk factor for breast cancer
2011-01-01
Introduction Mammographic breast density is a highly heritable (h2 > 0.6) and strong risk factor for breast cancer. We conducted a genome-wide linkage study to identify loci influencing mammographic breast density (MD). Methods Epidemiological data were assembled on 1,415 families from the Australia, Northern California and Ontario sites of the Breast Cancer Family Registry, and additional families recruited in Australia and Ontario. Families consisted of sister pairs with age-matched mammograms and data on factors known to influence MD. Single nucleotide polymorphism (SNP) genotyping was performed on 3,952 individuals using the Illumina Infinium 6K linkage panel. Results Using a variance components method, genome-wide linkage analysis was performed using quantitative traits obtained by adjusting MD measurements for known covariates. Our primary trait was formed by fitting a linear model to the square root of the percentage of the breast area that was dense (PMD), adjusting for age at mammogram, number of live births, menopausal status, weight, height, weight squared, and menopausal hormone therapy. The maximum logarithm of odds (LOD) score from the genome-wide scan was on chromosome 7p14.1-p13 (LOD = 2.69; 63.5 cM) for covariate-adjusted PMD, with a 1-LOD interval spanning 8.6 cM. A similar signal was seen for the covariate adjusted area of the breast that was dense (DA) phenotype. Simulations showed that the complete sample had adequate power to detect LOD scores of 3 or 3.5 for a locus accounting for 20% of phenotypic variance. A modest peak initially seen on chromosome 7q32.3-q34 increased in strength when only the 513 families with at least two sisters below 50 years of age were included in the analysis (LOD 3.2; 140.7 cM, 1-LOD interval spanning 9.6 cM). In a subgroup analysis, we also found a LOD score of 3.3 for DA phenotype on chromosome 12.11.22-q13.11 (60.8 cM, 1-LOD interval spanning 9.3 cM), overlapping a region identified in a previous study. Conclusions The suggestive peaks and the larger linkage signal seen in the subset of pedigrees with younger participants highlight regions of interest for further study to identify genes that determine MD, with the goal of understanding mammographic density and its involvement in susceptibility to breast cancer. PMID:22188651
Simpson, Claire L.; Wojciechowski, Robert; Ibay, Grace; Stambolian, Dwight
2011-01-01
Purpose Despite many years of research, most of the genetic factors contributing to myopia development remain unknown. Genetic studies have pointed to a strong inherited component, but although many candidate regions have been implicated, few genes have been positively identified. Methods We have previously reported 2 genomewide linkage scans in a population of 63 highly aggregated Ashkenazi Jewish families that identified a locus on chromosome 22. Here we used ordered subset analysis (OSA), conditioned on non-parametric linkage to chromosome 22 to detect other chromosomal regions which had evidence of linkage to myopia in subsets of the families, but not the overall sample. Results Strong evidence of linkage to a 19-cM linkage interval with a peak OSA nonparametric allele-sharing logarithm-of-odds (LOD) score of 3.14 on 20p12-q11.1 (ΔLOD=2.39, empirical p=0.029) was identified in a subset of 20 families that also exhibited strong evidence of linkage to chromosome 22. One other locus also presented with suggestive LOD scores >2.0 on chromosome 11p14-q14 and one locus on chromosome 6q22-q24 had an OSA LOD score=1.76 (ΔLOD=1.65, empirical p=0.02). Conclusions The chromosome 6 and 20 loci are entirely novel and appear linked in a subset of families whose myopia is known to be linked to chromosome 22. The chromosome 11 locus overlaps with the known Myopia-7 (MYP7, OMIM 609256) locus. Using ordered subset analysis allows us to find additional loci linked to myopia in subsets of families, and underlines the complex genetic heterogeneity of myopia even in highly aggregated families and genetically isolated populations such as the Ashkenazi Jews. PMID:21738393
Haghi, Ghasem; Arshi, Rohollah; Safaei, Alireza
2008-02-27
A high-performance liquid chromatography (HPLC) method for the qualitative and quantitative analysis of allantoin in silk and seed of Zea mays has been developed. Allantoin separation in crude extract was achieved using a C 18 column and phosphate buffer solution (pH 3.0) as a mobile phase at ambient temperature at a flow rate of 1.0 mL/min and detected at 210 nm. The results showed that the amount of allantoin in samples was between 14 and 271 mg/100 g of dry plant material. A comprehensive validation of the method including sensitivity, linearity, repeatability, and recovery was conducted. The calibration curve was linear over the range of 0.2-200 microg/mL with a correlation coefficient of r2>0.999. Limit of detection (LOD, S/N=3) and limit of quantification (LOQ) values of the allantoin were 0.05 and 0.2 microg/mL (1.0 and 4.0 ng) respectively. The relative standard deviation (RSD) value of the repeatability was reported within 1.2%. The average recovery of allantoin added to samples was 100.6% with RSD of 1.5%.
Van den Bulcke, Marc; Lievens, Antoon; Barbau-Piednoir, Elodie; MbongoloMbella, Guillaume; Roosens, Nancy; Sneyers, Myriam; Casi, Amaya Leunda
2010-03-01
The detection of genetically modified (GM) materials in food and feed products is a complex multi-step analytical process invoking screening, identification, and often quantification of the genetically modified organisms (GMO) present in a sample. "Combinatory qPCR SYBRGreen screening" (CoSYPS) is a matrix-based approach for determining the presence of GM plant materials in products. The CoSYPS decision-support system (DSS) interprets the analytical results of SYBRGREEN qPCR analysis based on four values: the C(t)- and T(m) values and the LOD and LOQ for each method. A theoretical explanation of the different concepts applied in CoSYPS analysis is given (GMO Universe, "Prime number tracing", matrix/combinatory approach) and documented using the RoundUp Ready soy GTS40-3-2 as an example. By applying a limited set of SYBRGREEN qPCR methods and through application of a newly developed "prime number"-based algorithm, the nature of subsets of corresponding GMO in a sample can be determined. Together, these analyses provide guidance for semi-quantitative estimation of GMO presence in a food and feed product.
NASA Technical Reports Server (NTRS)
Ferrario, J.; Byrne, C.; McDaniel, D.; Dupuy, A. Jr; Harless, R.
1996-01-01
As part of the U.S. EPA Dioxin Reassessment Program, the 2,3,7,8-chlorine-substituted dibenzo-p-dioxins and furans were measured at part per trillion (ppt) levels in beef fat collected from slaughter facilities in the United States. This is the first statistically designed national survey of these compounds in the U.S. beef supply. Analyte concentrations were determined by high-resolution gas chromatography/high-resolution mass spectrometry, using isotope dilution methodology. Method limits of detection on a whole weight basis were 0.05 ppt for TCDD and 0.10 ppt for TCDF, 0.50 ppt for the pentas (PeCDDs/PeCDFs)/hexas (HxCDDs/HxCDFs)/heptas (HpCDDs/HpCDFs), and 3.00 ppt for the octas (OCDD/OCDF). Method detection and quantitation limits were established on the basis of demonstrated performance criteria utilizing fortified samples rather than by conventional signal-to-noise or variability of response methods. The background subtraction procedures developed for this study minimized the likelihood of false positives and increased the confidence associated with reported values near the detection limits. Mean and median values for each of the 2,3,7,8-Cl-substituted dioxins and furans are reported, along with the supporting information required for their interpretation. The mean toxic equivalence values for the samples are 0.35 ppt (nondetects = 0) and 0.89 ppt (nondetects = 1/2 LOD).
Noorbazargan, Hassan; Nadji, Seyed Alireza; Samiee, Siamak Mirab; Paryan, Mahdi; Mohammadi-Yeganeh, Samira
2018-04-01
Background Viral load measurement is commonly applicable to monitor HIV infection in patients to determine the number of HIV-RNA in serum samples of individuals. The aim of the present study was to set up a highly specific, sensitive, and reproducible home-brewed Real-time PCR assay based on TaqMan chemistry to quantify HIV-1 RNA genome. Methods In this study, three sets of primer pairs and a TaqMan probe were designed for HIV subtypes conserved sequences. An internal control was included in this assay to evaluate the presence of inhibition. Standard curve and threshold cycle values were determined using in vitro transcribed RNA from int region of HIV-1. A serial dilution of RNA standards was generated by in vitro transcription, from 10 to 10 9 copies/ml to find the sensitivity and the limit of detection (LOD) of the assay and to evaluate its performance in a quantitative RT-PCR assay. Results The assay has a low LOD equivalent to 33.13 copies/ml of HIV-1 RNA and a linear range of detection from 10 to 10 9 copies/ml. The coefficient of variation (CV) for Inter and Intra-assay precision of this in-house HIV Real-time RT-PCR ranged from 0.28 to 2.49% and 0.72 to 4.47%, respectively. The analytical and clinical specificity was 100%. Conclusions The results indicate that the developed method has a suitable specificity and sensitivity and is highly reproducible and cost-benefit. Therefore, it will be useful to monitor HIV infection in plasma samples of individuals.
Cazorla-Reyes, Rocío; Fernández-Moreno, José Luis; Romero-González, Roberto; Frenich, Antonia Garrido; Vidal, José Luis Martínez
2011-07-15
A new multiresidue method has been developed and validated for the simultaneous extraction of more than two hundred pesticides, including non-polar and polar pesticides (carbamates, organochlorine, organophosphorous, pyrethroids, herbicides and insecticides) in urine at trace levels by gas and ultra high pressure liquid chromatography coupled to ion trap and triple quadrupole mass spectrometry, respectively (GC-IT-MS/MS, UHPLC-QqQ-MS/MS). Non-polar and polar pesticides were simultaneously extracted from urine samples by a simple and fast solid phase extraction (SPE) procedure using C(18) cartridges as sorbent, and dichloromethane as elution solvent. Recovery was in the range of 60-120%. Precision values expressed as relative standard deviation (RSD) were lower than 25%. Identification and confirmation of the compounds were performed by the use of retention time windows, comparison of spectra (GC-amenable compounds) or the estimation of the ion ratio (LC-amenable compounds). For GC-amenable pesticides, limits of detection (LODs) ranged from 0.001 to 0.436 μg L(-1) and limits of quantification (LOQs) from 0.003 to 1.452 μg L(-1). For LC-amenable pesticides, LODs ranged from 0.003 to 1.048 μg L(-1) and LOQs ranged from 0.011 to 3.494 μg L(-1). Finally, the optimized method was applied to the analysis of fourteen real samples of infants from agricultural population. Some pesticides such as methoxyfenozide, tebufenozide, piperonyl butoxide and propoxur were found at concentrations ranged from 1.61 to 24.4 μg L(-1), whereas methiocarb sulfoxide was detected at trace levels in two samples. Copyright © 2011 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Matusiewicz, Henryk; Ślachciński, Mariusz
2017-07-01
A miniaturized optical emission spectrometer (OES) with capacitively coupled argon microwave microplasma (μCMP) as and excitation source and chemical vapor generation (CVG) for sample introduction was constructed for the determination of trace Hg, As, Sb and Se. The applied method enabled simultaneous determination of hydride-forming elements (As, Sb, Se) and volatile Hg. Mercury cold vapor and the hydride volatile species of As, Sb and Se were generated when standard or sample solutions were separated from the liquid phase for transport to the capacitively coupled microwave microplasma and detection of their atomic emission. A univariate approach and the simplex optimization procedure were used to achieve optimized conditions and derive analytical figures of merit. The experimental concentration detection limits (LODs) for simultaneous determination, calculated as the concentration giving a signal equal to three times of the standard deviation of the blank (LOD, 3σblank criterion, peak height) were 3.0, 1.4, 1.5 and 3.8 ng mL- 1 for Hg, As, Sb and Se, respectively. The method was validated by the analysis of three Certified Reference Materials (NIST 2711, NRCC DOLT-2, NIST 1643e) of different matrix composition and by the standard addition technique. The method offers relatively good precision (RSD ranged from 5% to 8%) for microsampling (200 μL) analysis. The measured of contents of elements in certified reference materials were in good agreement with the certified values (Hg 1.99-6.25 μg g- 1, As 16.6-105 μg g- 1, Sb 19.4-56.88 μg g- 1, Se 1.52-11.68 μg g- 1), according to the Student t-test, for a confidence level of 95%.
Ares, Ana M; Ayuso, Irene; Bernal, José L; Nozal, María J; Bernal, José
2016-02-15
In this study, we investigate for the first time the presence of sulforaphane (SFN) residues in two of the most currently consumed food/dietary supplements, royal jelly and bee pollen. Chromatography-tandem mass spectrometry (LC-MS/MS) was the method employed, the mass spectrometer consisting of an ion-trap mass analyzer used with electrospray ionization (ESI) in positive ion mode. An efficient sample treatment involving a solvent extraction with methanol, centrifugation, and concentration in a rotary evaporator was proposed. In all cases average analyte recoveries were between 92 and 106%. Chromatographic analysis (16min) was performed on a core-shell technology based column (Kinetex C18, 150×4.6mm, 2.6μm, 100Å). The mobile phase consisted of 0.02M ammonium formate in water and acetonitrile, with a flow rate of 0.5mL/min in gradient elution mode. The fully validated method was selective, linear from 8 to 1000μg/kg (bee pollen), or from 10 to 1250μg/kg (royal jelly), precise and accurate; relative standard deviation (% RSD) and relative error (% RE) values were below 10%. Low limits of detection (LOD) and quantification (LOQ) were obtained, namely, 3μg/kg (LOD) and 8 (bee pollen) and 10 (royal jelly) μg/kg (LOQ). The method was applied for SFN analysis in several royal jelly and bee pollen samples. SFN was detected at trace levels in some bee pollen samples (<23μg/kg) examined, whilst SFN went undetected in the royal jelly samples analyzed. Copyright © 2016 Elsevier B.V. All rights reserved.
Validation of a mass spectrometry-based method for milk traces detection in baked food.
Lamberti, Cristina; Cristina, Lamberti; Acquadro, Elena; Elena, Acquadro; Corpillo, Davide; Davide, Corpillo; Giribaldi, Marzia; Marzia, Giribaldi; Decastelli, Lucia; Lucia, Decastelli; Garino, Cristiano; Cristiano, Garino; Arlorio, Marco; Marco, Arlorio; Ricciardi, Carlo; Carlo, Ricciardi; Cavallarin, Laura; Laura, Cavallarin; Giuffrida, Maria Gabriella; Gabriella, Giuffrida Maria
2016-05-15
A simple validated LC-MS/MS-based method was set up to detect milk contamination in bakery products, taking the effects of food processing into account for the evaluation of allergen recovery and quantification. Incurred cookies were prepared at eight levels of milk contamination and were cooked to expose all milk components, including allergenic proteins, to food processing conditions. Remarkable results were obtained in term of sufficiently low LOD and LOQ (1.3 and 4 mg/kg cookies, respectively). Precision was calculated as intra-day repeatability (RSD in the 5-20% range) and inter-day repeatability (4 days; RSD never exceeded 12%). The extraction recovery values ranged from 20% to 26%. Method applicability was evaluated by analysing commercial cookies labelled either as "milk-free" or "may contain milk". Although the ELISA methodology is considered the gold standard for detecting allergens in foods, this robust LC-MS/MS approach should be a useful confirmatory method for assessing and certifying "milk-free" food products. Copyright © 2015 Elsevier Ltd. All rights reserved.
Li, Zhuqing; Li, Xiang; Wang, Canhua; Song, Guiwen; Pi, Liqun; Zheng, Lan; Zhang, Dabing; Yang, Litao
2017-09-27
Multiple-target plasmid DNA reference materials have been generated and utilized as good substitutes of matrix-based reference materials in the analysis of genetically modified organisms (GMOs). Herein, we report the construction of one multiple-target plasmid reference molecule, pCAN, which harbors eight GM canola event-specific sequences (RF1, RF2, MS1, MS8, Topas 19/2, Oxy235, RT73, and T45) and a partial sequence of the canola endogenous reference gene PEP. The applicability of this plasmid reference material in qualitative and quantitative PCR assays of the eight GM canola events was evaluated, including the analysis of specificity, limit of detection (LOD), limit of quantification (LOQ), and performance of pCAN in the analysis of various canola samples, etc. The LODs are 15 copies for RF2, MS1, and RT73 assays using pCAN as the calibrator and 10 genome copies for the other events. The LOQ in each event-specific real-time PCR assay is 20 copies. In quantitative real-time PCR analysis, the PCR efficiencies of all event-specific and PEP assays are between 91% and 97%, and the squared regression coefficients (R 2 ) are all higher than 0.99. The quantification bias values varied from 0.47% to 20.68% with relative standard deviation (RSD) from 1.06% to 24.61% in the quantification of simulated samples. Furthermore, 10 practical canola samples sampled from imported shipments in the port of Shanghai, China, were analyzed employing pCAN as the calibrator, and the results were comparable with those assays using commercial certified materials as the calibrator. Concluding from these results, we believe that this newly developed pCAN plasmid is one good candidate for being a plasmid DNA reference material in the detection and quantification of the eight GM canola events in routine analysis.
Yahaya, Abdulrazaq; Okoh, Omobola O; Okoh, Anthony I; Adeniji, Abiodun O
2017-11-10
Most organochlorine pesticides (OCPs) which are increasingly used in agriculture and industry are not biodegradable and thereby persist in the environment for a very long period of time. They are capable of negatively impacting the health of humans and biota when present in a higher concentration than recommended. This study evaluated the concentrations of 17 OCPs in surface water samples collected from six sampling sites along the course of the Buffalo River in Eastern Cape, South Africa, between December 2015 and May 2016. The samples were subjected to solvent extraction, followed by florisil clean up, and analyzed using gas chromatography coupled with an electron capture detector. The individual concentrations of OCPs detected ranged from
Finch, S J; Chen, C H; Gordon, D; Mendell, N R
2001-12-01
This study compared the performance of the maximum lod (MLOD), maximum heterogeneity lod (MHLOD), maximum non-parametric linkage score (MNPL), maximum Kong and Cox linear extension (MKC(lin)) of NPL, and maximum Kong and Cox exponential extension (MKC(exp)) of NPL as calculated in Genehunter 1.2 and Genehunter-Plus. Our performance measure was the distance between the marker with maximum value for each linkage statistic and the trait locus. We performed a simulation study considering: 1) four modes of transmission, 2) 100 replicates for each model, 3) 58 pedigrees (with 592 subjects) per replicate, 4) three linked marker loci each having three equally frequent alleles, and 5) either 0% unlinked families (linkage homogeneity) or 50% unlinked families (linkage heterogeneity). For each replicate, we obtained the Haldane map position of the location at which each of the five statistics is maximized. The MLOD and MHLOD were obtained by maximizing over penetrances, phenocopy rate, and risk-allele frequencies. For the models simulated, MHLOD appeared to be the best statistic both in terms of identifying a marker locus having the smallest mean distance from the trait locus and in terms of the strongest negative correlation between maximum linkage statistic and distance of the identified position and the trait locus. The marker loci with maximum value of the Kong and Cox extensions of the NPL statistic also were closer to the trait locus than the marker locus with maximum value of the NPL statistic. Copyright 2001 Wiley-Liss, Inc.
Diagnosing Prion Diseases: Mass Spectrometry-Based Approaches
USDA-ARS?s Scientific Manuscript database
Mass spectrometry is an established means of quantitating the prions present in infected hamsters. Calibration curves relating the area ratios of the selected analyte peptides and their oxidized analogs to stable isotope labeled internal standards were prepared. The limit of detection (LOD) and limi...
Development of neuraminidase detection using gold nanoparticles boron-doped diamond electrodes.
Wahyuni, Wulan T; Ivandini, Tribidasari A; Saepudin, Endang; Einaga, Yasuaki
2016-03-15
Gold nanoparticles-modified boron-doped diamond (AuNPs-BDD) electrodes, which were prepared with a self-assembly deposition of AuNPs at amine-terminated boron-doped diamond, were examined for voltammetric detection of neuraminidase (NA). The detection method was performed based on the difference of electrochemical responses of zanamivir at gold surface before and after the reaction with NA in phosphate buffer solution (PBS, pH 5.5). A linear calibration curve for zanamivir in 0.1 M PBS in the absence of NA was achieved in the concentration range of 1 × 10(-6) to 1 × 10(-5) M (R(2) = 0.99) with an estimated limit of detection (LOD) of 2.29 × 10(-6) M. Furthermore, using its reaction with 1.00 × 10(-5) M zanamivir, a linear calibration curve of NA can be obtained in the concentration range of 0-12 mU (R(2) = 0.99) with an estimated LOD of 0.12 mU. High reproducibility was shown with a relative standard deviation (RSD) of 1.14% (n = 30). These performances could be maintained when the detection was performed in mucin matrix. Comparison performed using gold-modified BDD (Au-BDD) electrodes suggested that the good performance of the detection method is due to the stability of the gold particles position at the BDD surface. Copyright © 2016 Elsevier Inc. All rights reserved.
Oh, Seo Yeong; Heo, Nam Su; Shukla, Shruti; Cho, Hye-Jin; Vilian, A T Ezhil; Kim, Jinwoon; Lee, Sang Yup; Han, Young-Kyu; Yoo, Seung Min; Huh, Yun Suk
2017-08-31
A non-labeled, portable plasmonic biosensor-based device was developed to enable the ultra-sensitive and selective detection of Salmonella typhimurium in pork meat samples. Specifically, a plasmonic sensor, using the self-assembly of gold nanoparticles (AuNPs) to achieve a regulated diameter of 20 nm for the AuNP monolayers, was used to conduct high-density deposition on a transparent substrate, which produced longitudinal wavelength extinction shifts via a localized surface plasmon resonance (LSPR) signal. The developed aptamers conjugated to the LSPR sensing chips revealed an ultra-sensitive upper limit of detection (LOD) of approximately 10 4 cfu/mL for S. typhimurium in pure culture under the optimal assay conditions, with a total analysis time of 30-35 min. When the LSPR sensing chips were applied on artificially contaminated pork meat samples, S. typhimurium in the spiked pork meat samples was also detected at an LOD of 1.0 × 10 4 cfu/mL. The developed method could detect S. typhimurium in spiked pork meat samples without a pre-enrichment step. Additionally, the LSPR sensing chips developed against S. typhimurium were not susceptible to any effect of the food matrix or background contaminant microflora. These findings confirmed that the developed gold nanoparticle-aptamer-based LSPR sensing chips could facilitate sensitive detection of S. typhimurium in food samples.
A method for detecting fungal contaminants in wall cavities.
Spurgeon, Joe C
2003-01-01
This article describes a practical method for detecting the presence of both fungal spores and culturable fungi in wall cavities. Culturable fungi were collected in 25 mm cassettes containing 0.8 microm mixed cellulose ester filters using aggressive sampling conditions. Both culturable fungi and fungal spores were collected in modified slotted-disk cassettes. The sample volume was 4 L. The filters were examined microscopically and dilution plated onto multiple culture media. Collecting airborne samples in filter cassettes was an effective method for assessing wall cavities for fungal contaminants, especially because this method allowed the sample to be analyzed by both microscopy and culture media. Assessment criteria were developed that allowed the sample results to be used to classify wall cavities as either uncontaminated or contaminated. As a criterion, wall cavities with concentrations of culturable fungi below the limit of detection (LOD) were classified as uncontaminated, whereas those cavities with detectable concentrations of culturable fungi were classified as contaminated. A total of 150 wall cavities was sampled as part of a field project. The concentrations of culturable fungi were below the LOD in 34% of the samples, whereas Aspergillus and/or Penicillium were the only fungal genera detected in 69% of the samples in which culturable fungi were detected. Spore counting resulted in the detection of Stachybotrys-like spores in 25% of the samples that were analyzed, whereas Stachybotrys chartarum colonies were only detected on 2% of malt extract agar plates and on 6% of corn meal agar plates.
Paramu, Sobhana
2016-12-01
Anti-mullerian hormone (AMH) is a marker of the activity of recruitable ovarian follicles. It is useful in the prediction of ovarian reserve. Women with polycystic ovarian syndrome (PCOS) have elevated circulating and intrafollicular AMH levels. Laparoscopic ovarian drilling (LOD) in patients with PCOS destroys ovarian androgen-producing tissue and reduces their peripheral conversion to estrogens. Identifying factors that determine the response of patients with PCOS to LOD will help in selecting the patients who would likely benefit from this treatment. AMH is one such marker that can predict the response to LOD. To evaluate the effect of LOD on serum AMH levels among PCOS responders and non-responders and the usefulness of AMH as a tool in predicting the response to LOD, and to whether there was loss of ovarian function after LOD. This is a prospective cohort study including 30 clomiphene-resistant women with anovulatory PCOS undergoing LOD. Statistical analysis was performed to evaluate the effect of LOD on serum levels of AMH on these women. A significant fall in the levels of AMH was observed after LOD in both responders and non-responders (p<0.001). Women with AMH >8.3 ng/mL showed a significantly lower ovulation rate (33.3%). LOD was not associated with a risk of diminished ovarian reserve. LOD is an effective first-line treatment for women with PCOS who are clomiphene resistant. LOD has no negative effect on ovarian reserve. AMH is a useful marker in predicting the outcome of LOD.
Shortt, Colleen; Phan, Kim; Hill, Stephen A; Worster, Andrew; Kavsak, Peter A
2015-03-01
The application of "undetectable" high-sensitivity cardiac troponin (hs-cTn) concentrations to "rule-out" myocardial infarction is appealing, but there are analytical concerns and a lack of consensus on what concentration should be used to define the lower reportable limit; i.e., limit of detection (LoD) or limit of blank. An alternative approach is to utilize a measurable hs-cTn concentration that identifies patients at low-risk for a future cardiovascular event combined with another prognostic test, such as glucose. We assessed both of these approaches in different emergency department (ED) cohorts to rule-out an event. We used cohort 1 (all-comer ED population, n=4773; derivation cohort) to determine the most appropriate approach at presentation (i.e., Dual Panel test: hs-cTn/glucose vs. LoD vs. LoD/glucose) for an early rule-out of hospital death using the Abbott ARCHITECT hs-cTnI assay. We used cohort 2 (n=144) and cohort 3 (n=127), both early chest pain onset ED populations as the verification datasets (outcome: composite cardiovascular event at 72h) with three hs-cTn assays assessed (Abbott Laboratories, Beckman Coulter, Roche Diagnostics). In cohort 1, the sensitivity was >99% for all three approaches; however the specificity (11%; 95% CI: 10-12%) was significantly higher for the Dual Panel as compared to the LoD approach (specificity=5%; 95% CI: 4-6%). Verification of the Dual Panel in cohort 2 and cohort 3 revealed 100% sensitivity and negative predictive values for all three hs-cTn assays. The combination of a "healthy" hs-cTn concentration with glucose might effectively rule-out patients for an acute cardiovascular event at ED presentation. Copyright © 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Ngoensawat, Umphan; Rijiravanich, Patsamon; Somasundrum, Mithran; Surareungchai, Werasak
2014-11-21
We have described a highly sensitive method for detecting DNA hybridisation using a redox-labeled stem loop probe. The redox labels were poly(styrene-co-acrylic) (PSA) spheres of 454 nm diameter, modified by methylene blue (MB) deposited alternatively with poly(sodium 4-styrene sulphonate) (PSS) in a layer-by-layer process. Each PSA sphere carried approx. 3.7 × 10(5) molecules of MB, as determined optically. DIG-tagged stem loop probes were immobilised on screen printed electrodes bearing anti-DIG antibodies. Binding with the target enabled straightening of the stem loop, which made attachment to the MB-coated PSA spheres possible. For measuring the current from the direct reduction of MB by differential pulse voltammetry, a 30 mer DNA target common to 70 strains of Escherichia coli was calibrated across the range 1.0 fM to 100 pM (gradient = 3.2 × 10(-8) A (log fM)(-1), r(2) = 0.95, n = 60), with an LOD of ∼58 fM. By using Fe(CN)6(3-/4-) as a solution phase mediator for the MB reduction, we were able to lower the LOD to ∼39 aM (gradient = 5.95 × 10(-8) A (log aM)(-1), r(2) = 0.96, n = 30), which corresponds to the detection of 0.76 ag (∼50 molecules) in the 2 μL analyte sample. We hypothesise that the lowering of the LOD was due to the fact that not all the MB labels were able to contact the electrode surface.
NASA Astrophysics Data System (ADS)
Yugatama, A.; Rohmani, S.; Dewangga, A.
2018-03-01
Atorvastatin is the primary choice for dyslipidemia treatment. Due to patent expiration of atorvastatin, the pharmaceutical industry makes copy of the drug. Therefore, the development methods for tablet quality tests involving atorvastatin concentration on tablets needs to be performed. The purpose of this research was to develop and validate the simple atorvastatin tablet analytical method by HPLC. HPLC system used in this experiment consisted of column Cosmosil C18 (150 x 4,6 mm, 5 µm) as the stationary reverse phase chomatography, a mixture of methanol-water at pH 3 (80:20 v/v) as the mobile phase, flow rate of 1 mL/min, and UV detector at wavelength of 245 nm. Validation methods were including: selectivity, linearity, accuracy, precision, limit of detection (LOD), and limit of quantitation (LOQ). The results of this study indicate that the developed method had good validation including selectivity, linearity, accuracy, precision, LOD, and LOQ for analysis of atorvastatin tablet content. LOD and LOQ were 0.2 and 0.7 ng/mL, and the linearity range were 20 - 120 ng/mL.
Iwasaki, Motoki; Mukai, Tomomi; Takachi, Ribeka; Ishihara, Junko; Totsuka, Yukari; Tsugane, Shoichiro
2014-08-01
Clarification of the putative etiologic role of heterocyclic aromatic amines (HAAs) in the development of cancer requires a validated assessment tool for dietary HAAs. This study primarily aimed to evaluate the validity of a food frequency questionnaire (FFQ) in estimating HAA intake, using 2-amino-1-methyl-6-phenylimidazo[4,5-b]pyridine (PhIP) level in human hair as the reference method. We first updated analytical methods of PhIP using liquid chromatography-electrospray ionization/tandem mass spectrometry (LC-ESI/MS/MS) and measured 44 fur samples from nine rats from a feeding study as part-verification of the quantitative performance of LC-ESI/MS/MS. We next measured PhIP level in human hair samples from a validation study of the FFQ (n = 65). HAA intake from the FFQ was estimated using information on intake from six fish items and seven meat items and data on HAA content in each food item. Correlation coefficients between PhIP level in human hair and HAA intake from the FFQ were calculated. The animal feeding study of PhIP found a significant dose-response relationship between dosage and PhIP in rat fur. Mean level was 53.8 pg/g hair among subjects with values over the limit of detection (LOD) (n = 57). We found significant positive correlation coefficients between PhIP in human hair and HAA intake from the FFQ, with Spearman rank correlation coefficients of 0.35 for all subjects, 0.21 for subjects with over LOD values, and 0.34 for subjects with over limit of quantification. Findings from the validation study suggest that the FFQ is reasonably valid for the assessment of HAA intake.
Küme, Tuncay; Sağlam, Barıs; Ergon, Cem; Sisman, Ali Rıza
2018-01-01
The aim of this study is to evaluate and compare the analytical performance characteristics of the two creatinine methods based on the Jaffe and enzymatic methods. Two original creatinine methods, Jaffe and enzymatic, were evaluated on Architect c16000 automated analyzer via limit of detection (LOD) and limit of quantitation (LOQ), linearity, intra-assay and inter-assay precision, and comparability in serum and urine samples. The method comparison and bias estimation using patient samples according to CLSI guideline were performed on 230 serum and 141 urine samples by analyzing on the same auto-analyzer. The LODs were determined as 0.1 mg/dL for both serum methods and as 0.25 and 0.07 mg/dL for the Jaffe and the enzymatic urine method respectively. The LOQs were similar with 0.05 mg/dL value for both serum methods, and enzymatic urine method had a lower LOQ than Jaffe urine method, values at 0.5 and 2 mg/dL respectively. Both methods were linear up to 65 mg/dL for serum and 260 mg/dL for urine. The intra-assay and inter-assay precision data were under desirable levels in both methods. The higher correlations were determined between two methods in serum and urine (r=.9994, r=.9998 respectively). On the other hand, Jaffe method gave the higher creatinine results than enzymatic method, especially at the low concentrations in both serum and urine. Both Jaffe and enzymatic methods were found to meet the analytical performance requirements in routine use. However, enzymatic method was found to have better performance in low creatinine levels. © 2017 Wiley Periodicals, Inc.
Determination of whey adulteration in milk powder by using laser induced breakdown spectroscopy.
Bilge, Gonca; Sezer, Banu; Eseller, Kemal Efe; Berberoglu, Halil; Topcu, Ali; Boyaci, Ismail Hakki
2016-12-01
A rapid and in situ method has been developed to detect and quantify adulterated milk powder through adding whey powder by using laser induced breakdown spectroscopy (LIBS). The methodology is based on elemental composition differences between milk and whey products. Milk powder, sweet and acid whey powders were produced as standard samples, and milk powder was adulterated with whey powders. Based on LIBS spectra of standard samples and commercial products, species was identified using principle component analysis (PCA) method, and discrimination rate of milk and whey powders was found as 80.5%. Calibration curves were obtained with partial least squares regression (PLS). Correlation coefficient (R(2)) and limit of detection (LOD) values were 0.981 and 1.55% for adulteration with sweet whey powder, and 0.985 and 0.55% for adulteration with acid whey powder, respectively. The results were found to be consistent with the data from inductively coupled plasma - mass spectrometer (ICP-MS) method. Copyright © 2016 Elsevier Ltd. All rights reserved.
Residue depletion of tilmicosin in chicken tissues.
Zhang, Yue; Jiang, Haiyang; Jin, Xingjun; Shen, Zhangqi; Shen, Jianzhong; Fu, Caixia; Guo, Junlin
2004-05-05
A high-performance liquid chromatography (HPLC) method with detection at 290 nm was modified and validated for the determination of tilmicosin residues in broiler chicken tissues. The limits of detection (LOD) of the method were 0.01 microg/g for muscle and 0.025 microg/g for liver and kidney. Average recoveries ranged from 80.4 to 88.3%. Relative standard deviation values ranged from 5.2 to 12.1%. Residue depletion of tilmicosin in broiler chickens was examined after dosing over a 5-day period by incorporation of the drug into drinking water at 37.5 and 75.0 mg/L. Tilmicosin concentrations in liver and kidney were highest on day 3 of medication and on day 5 in muscle, in both low- and high-dose groups. The residue levels in both groups were significantly higher in liver than in kidney or muscle. A minimum withdrawal time of 9 days was indicated for residue levels in muscle, liver, and kidney tissues below the maximum residue level (MRL).
Quigley, Andrew; Walsh, Siobhán W; Hayes, Eva; Connolly, Damian; Cummins, Wayne
2018-06-07
A dispersive liquid-liquid microextraction (DLLME) method, combined with HPLC-UV detection, was developed for the extraction and preconcentration of δ-tocopherol from bovine milk. This method was used to study the effect of supplementing cow feed with the seaweed Ascophyllum nodosum on vitamin content in milk. The optimal experimental conditions were determined: 200 μL of chloroform (extraction solvent), 1.0 mL of ethanol (dispersive solvent), 5 mL of water (aqueous phase). Under these optimal conditions the DLLME method provided linearity in the range 0.01 μg/mL to 8 μg/mL with R 2 values of 0.998. Limit of detection (LOD) was 0.01 μg/mL, while the enrichment factor was 89. Cow feed that was supplemented with Ascophyllum nodosum was shown to increase δ-tocopherol levels from 3.82 μg/mL to 5.96 μg/mL. Copyright © 2018. Published by Elsevier B.V.
Giampaolino, Pierluigi; Morra, Ilaria; Tommaselli, Giovanni Antonio; Di Carlo, Costantino; Nappi, Carmine; Bifulco, Giuseppe
2016-10-01
To compare conventional laparoscopic ovarian drilling (LOD) with transvaginal hydrolaparoscopy (THL) ovarian drilling in terms of ovarian adhesion formation, evaluated using office THL during follow-up in CC-resistant anovulatory patients affected by PCOS. Prospective randomized study on 246 CC-resistant women with PCOS. The patients enrolled were divided into two groups, 123 were scheduled to undergo LOD and 123 to undergo THL ovarian drilling. Six months after the procedure all patients were offered office transvaginal hydrolaparoscopy (THL) follow-up, under local anesthesia to evaluate adhesion formation. Duration of the procedure was significantly shorter in the THL group in comparison with LOD group (p < 0.0001). No intra- or post-operative complication was observed in any of the patients in both groups. Post-operative THL follow-up after 6 months showed that 15 (15.5 %) patients in the THL group and 73 (70.2 %) in the LOD group showed the presence of ovarian adhesion. This difference was highly significant with a p value <0.0001 and a relative risk of 0.22 [95 % IC 0.133-0.350]. This study seems to indicate that THL ovarian drilling may reduce the risk of ovarian adhesion formation and could be used as a safe and effective option to reduce ovarian adhesion formation in patients undergoing ovarian drilling.
Valente, Maria João; Carvalho, Félix; Bastos, M Lourdes; Carvalho, Márcia; de Pinho, Paula Guedes
2010-11-15
Acute renal failure is a common finding in cocaine abusers. While cocaine metabolism may contribute to its nephrotoxic mechanisms, its pharmacokinetics in kidney cells is hitherto to be clarified. Primary cultures of human proximal tubular cells (HPTCs) provide a well-characterized in vitro model, phenotypically representative of HPTCs in vivo. Thus, the present work describes the first sensitive gas chromatography/ion trap-mass spectrometry (GC/IT-MS) method for measurement of cocaine and its metabolites benzoylecgonine (BE) and norcocaine (NCOC) using a primary culture of HPTCs as cellular matrix, following solid phase extraction (SPE) and derivatization with N-methyl-N-(trimethylsilyl)trifluoroacetamide (MSTFA). The application of this methodology also enables the identification of two other cocaine metabolites: ecgonine methyl ester (EME) and anhydroecgonine methyl ester (AEME). The validation of the method was performed through the evaluation of selectivity, linearity, precision and accuracy, limit of detection (LOD), and limit of quantification (LOQ). Its applicability was demonstrated through the quantification of cocaine, BE and NCOC in primary cultured HPTCs after incubation, at physiological conditions, with 1 mM cocaine for 72 h. The developed GC/IT-MS method was found to be linear (r² > 0.99). The intra-day precision varied between 3.6% and 13.5% and the values of accuracy between 92.7% and 111.9%. The LOD values for cocaine, BE and NCOC were 0.97±0.09, 0.40±0.04 and 20.89±1.81 ng/mL, respectively, and 3.24±0.30, 1.34±0.14 and 69.62±6.05 ng/mL as LOQ values. Copyright © 2010 Elsevier B.V. All rights reserved.
Bent, Grace-Anne; Maragh, Paul; Dasgupta, Tara
2012-07-15
The acrylamide levels in commercial and homemade Caribbean foods were determined by pre-derivatisation of acrylamide to 2-bromopropenamide and analysed by gas chromatography with mass spectrometric (GC/MS) detection. Over 100 Caribbean food samples were analysed for the presence of acrylamide. These samples include: biscuits, breakfast cereals, banana chips and home-prepared foods: breadfruit; Artocarpus altilis, banana fritters, and dumplings. The limit of detection (LOD) for the GC/MS method was found to be dependent on the type of column used for the GC/MS analysis. The DB-1701 and the DB-VRX columns gave LODs of 20 and 4 μg/kg, respectively. Acrylamide has not been found in raw foods or foods which have been cooked by boiling. Its content in all other foods had concentrations in the range, 65-3,640 μg/kg. The relationship between acrylamide levels and precursor concentration as well as the health implications of our findings are discussed. Copyright © 2012 Elsevier Ltd. All rights reserved.
Herrero, P; Bäuerlein, P S; Emke, E; Pocurull, E; de Voogt, P
2014-08-22
In this short communication we report on the technical implementations of coupling an asymmetric flow field-flow fractionation (AF4) instrument to a high resolution mass spectrometer (Orbitrap) using an atmospheric photoionisation interface. This will allow for the first time online identification of different fullerenes in aqueous samples after their aggregates have been fractionated in the FFF channel. Quality parameters such as limits of detection (LODs), limits of quantification (LOQs) or linear range were evaluated and they were in the range of hundreds ng/L for LODs and LOQs and the detector response was linear in the range tested (up to ∼20 μg/L). The low detection and quantification limits make this technique useful for future environmental or ecotoxicology studies in which low concentration levels are expected for fullerenes and common on-line detectors such as UV or MALS do not have enough sensitivity and selectivity. Copyright © 2014 The Authors. Published by Elsevier B.V. All rights reserved.
TLS for generating multi-LOD of 3D building model
NASA Astrophysics Data System (ADS)
Akmalia, R.; Setan, H.; Majid, Z.; Suwardhi, D.; Chong, A.
2014-02-01
The popularity of Terrestrial Laser Scanners (TLS) to capture three dimensional (3D) objects has been used widely for various applications. Development in 3D models has also led people to visualize the environment in 3D. Visualization of objects in a city environment in 3D can be useful for many applications. However, different applications require different kind of 3D models. Since a building is an important object, CityGML has defined a standard for 3D building models at four different levels of detail (LOD). In this research, the advantages of TLS for capturing buildings and the modelling process of the point cloud can be explored. TLS will be used to capture all the building details to generate multi-LOD. This task, in previous works, involves usually the integration of several sensors. However, in this research, point cloud from TLS will be processed to generate the LOD3 model. LOD2 and LOD1 will then be generalized from the resulting LOD3 model. Result from this research is a guiding process to generate the multi-LOD of 3D building starting from LOD3 using TLS. Lastly, the visualization for multi-LOD model will also be shown.
Oh, Jeong-Wook; Yoon, Yeo Woon; Heo, Jihye; Yu, Joonhee; Kim, Hasuck; Kim, Tae Hyun
2016-01-15
Negatively charged multi-walled carbon nanotubes (MWCNTs) were prepared using simple sonication technique with non-toxic citric acid (CA) for the electrochemical detection of dopamine (DA). CA/MWCNTs were placed on glassy carbon (GC) electrodes by drop-casting method and then electrochemical determinations of DA were performed in the presence of highly concentrated ascorbic acid (AA). For the comparison of the charge effect on MWCNTs surface, positively charged polyethyleneimine (PEI)/MWCNT/GC electrode and pristine MWCNT/GC electrode were also prepared. Contrary to conventional GC electrode, all three types of MWCNT modified electrodes (CA/MWCNT/GC, PEI/MWCNT/GC, and pristine MWCNT/GC) can discriminate ~μM of DA from 1mM AA using cyclic voltammetry (CV) and differential pulse voltammetry (DPV) due to the inherent electrocatalytic effect of MWCNTs. Compared to positively charged PEI/MWCNT/GC and pristine MWCNT/GC electrodes, negatively charged CA/MWCNT/GC electrode remarkably enhanced the electrochemical sensitivity and selectivity of DA, showing the linear relationship between DPV signal and DA concentration in the range of 10-1000nM even in the presence of ~10(5) times concentrated AA, which is attributed to the synergistic effect of the electrostatic interaction between cationic DA molecules and negatively charged MWCNTs and the inherent electrocatalytic property of MWCNT. As a result, the limit of detection (LOD) of DA for CA/MWCNT/GC electrode was 4.2nM, which is 5.2 and 16.5 times better than those for MWCNT/GC electrode and PEI/MWCNT/GC electrode even in the presence of 1mM AA. This LOD value for DA at CA/MWCNT/GC electrode is one of the lowest values compared to the previous reports and is low enough for the early diagnosis of neurological disorder in the presence of physiological AA concentration (~0.5mM). In addition, the high selectivity and sensitivity of DA at CA/MWCNT/GC electrode were well kept even in the presence of both 1mM AA and 10μM uric acid (UA) as similar as neurophysiological concentration. Copyright © 2015 Elsevier B.V. All rights reserved.
Bordiga, M; Lorenzo, C; Pardo, F; Salinas, M R; Travaglia, F; Arlorio, M; Coïsson, J D; Garde-Cerdán, T
2016-04-15
The validation of a HPLC-PDA-MS/MS chromatographic method for the quali/quantitative characterization of histaminol, hydroxytyrosol, tyrosol, and tryptophol in wine has been described and discussed. Four standards showed a good linearity with high correlation coefficient values (over 0.9989) and LOD and LOQ were 0.001-0.015 mg/L and 0.004-0.045 mg/L, respectively. Furthermore, this study reported how factors such as temperature, alcoholic degree, and amino acids concentration are able to influence the formation of these four alcohols in Monastrell wines. The quantification values of these alcohols has been detected both at the half and end of alcoholic fermentation, and at the end of malolactic fermentation. In relation to interactions between factors, several significant variations emerged (p ⩽ 0.001). The impact of amino acids supplementation in Monastrell must it has been demonstrated, mainly in regards to histaminol and tryptophol. Copyright © 2015 Elsevier Ltd. All rights reserved.
Gerona, Roy R.; Woodruff, Tracey J.; Dickenson, Carrie A.; Pan, Janet; Schwartz, Jackie M.; Sen, Saunak; Friesen, Matthew M.; Fujimoto, Victor Y.; Hunt, Patricia A.
2013-01-01
Bisphenol-A (BPA) is an endocrine disrupting chemical used in numerous consumer products, resulting in universal exposure in the United States. Prenatal exposure to BPA is associated with numerous reproductive and developmental effects in animals. However, little is known about human fetal exposure or metabolism of BPA during mid-gestation. In the present study, we present a new liquid chromatography-tandem mass spectrometry method to directly measure concentrations of BPA and two predominant metabolic conjugates – BPA glucuronide and BPA sulfate – in umbilical cord serum collected from elective 2nd trimester pregnancy terminations. We detected at least one form of BPA in all umbilical cord serum samples: BPA (GM 0.16; range
Sequence Optimized Real-Time RT-PCR Assay for Detection of Crimean-Congo Hemorrhagic Fever Virus
2017-03-21
19-23]. Real-56 time reverse-transcription PCR remains the gold standard for quantitative , sensitive, and specific 57 detection of CCHFV; however...five-fold in two different series , and samples were run by real- time RT-PCR 116 in triplicate. The preliminary LOD was the lowest RNA dilution where...1 Sequence optimized real- time RT-PCR assay for detection of Crimean-Congo hemorrhagic fever 1 virus 2 3 JW Koehler1, KL Delp1, AT Hall1, SP
Krüger, Stephanie; Bürmann, Laura; Morlock, Gertrud E
2015-03-25
The scarce availability of nongenetically modified soybeans on the world market represents a growing problem for food manufacturers. Hence, in this study the effects of substituting soybean with sunflower lecithin were investigated with regard to chocolate production. The glycerophospholipid pattern of the different lecithin samples was investigated by high-performance thin-layer chromatography fluorescence detection (HPTLC-FLD) and by HPTLC-positive ion electrospray ionization mass spectrometry (ESI(+)-MS) via the TLC-MS Interface and by scanning HPTLC-matrix-assisted laser desorption ionization-time-of-flight mass spectrometry (MALDI-TOFMS). Especially, the contents of phosphatidylcholine (PC) and phosphatidylethanolamine (PE) were of interest due to the influencing effects of these two glycerophospholipids on the rheological parameters of chocolate production. The lecithin substitution led to only slight differences in the rheological parameters of milk and dark chocolate. Limits of detection (LODs) and limits of quantification (LOQs) of seven glycerophospholipids were studied for three detection modes. Mean LODs ranged from 8 to 40 mg/kg for HPTLC-FLD and, using a single-quadrupole MS, from 10 to 280 mg/kg for HPTLC-ESI(+)-MS as well as from 15 to 310 mg/kg for HPTLC-FLD-ESI(+)-MS recorded after derivatization with the primuline reagent.
Taghdisi, Seyed Mohammad; Danesh, Noor Mohammad; Emrani, Ahmad Sarreshtehdar; Ramezani, Mohammad; Abnous, Khalil
2015-11-15
Cocaine is a strong central nervous system stimulant and one of the most commonly abused drugs. In this study, an electrochemical aptasensor was designed for sensitive and selective detection of cocaine, based on single-walled carbon nanotubes (SWNTs), gold electrode and complimentary strand of aptamer (CS). This electrochemical aptasensor inherits properties of SWNTs and gold such as large surface area and high electrochemical conductivity, as well as high affinity and selectivity of aptamer toward its target and the stronger interaction of SWNTs with single-stranded DNA (ssDNA) than double-stranded DNA (dsDNA). In the absence of cocaine, a little amount of SWNTs bind to Aptamer-CS-modified electrode, so that the electrochemical signal is weak. In the presence of cocaine, aptamer binds to cocaine, leaves the surface of electrode. So that, a large amount of SWNTs bind to CS-modified electrode, generating to a strong electrochemical signal. The designed electrochemical aptasensor showed good selectivity toward cocaine with a limit of detection (LOD) as low as 105 pM. Moreover, the fabricated electrochemical aptasensor was successfully applied to detect cocaine in serum with a LOD as low as 136 pM. Copyright © 2015 Elsevier B.V. All rights reserved.
Omar, Mei Musa Ali; Elbashir, Abdalla Ahmed; Schmitz, Oliver J
2017-01-01
Simple and inexpensive capillary electrophoresis with UV-detection method (CE-UV) was optimized and validated for determination of six amino acids namely (alanine, asparagine, glutamine, proline, serine and valine) for Sudanese food. Amino acids in the samples were derivatized with 4-chloro-7-nitro-2,1,3-benzoxadiazole (NBD-Cl) prior to CE-UV analysis. Labeling reaction conditions (100mM borate buffer at pH 8.5, labeling reaction time 60min, temperature 70°C and NBD-Cl concentration 40mM) were systematically investigated. The optimal conditions for the separation were 100mM borate buffer at pH 9.7 and detected at 475nm. The method was validated in terms of linearity, limit of detection (LOD), limit of quantification (LOQ), precision (repeatability) (RSD%) and accuracy (recovery). Good linearity was achieved for all amino acids (r(2)>0.9981) in the concentration range of 2.5-40mg/L. The LODs in the range of 0.32-0.56mg/L were obtained. Recoveries of amino acids ranging from 85% to 108%, (n=3) were obtained. The validated method was successfully applied for the determination of amino acids for Sudanese food samples. Copyright © 2016 Elsevier Ltd. All rights reserved.
On-line/on-site analysis of heavy metals in water and soils by laser induced breakdown spectroscopy
NASA Astrophysics Data System (ADS)
Meng, Deshuo; Zhao, Nanjing; Wang, Yuanyuan; Ma, Mingjun; Fang, Li; Gu, Yanhong; Jia, Yao; Liu, Jianguo
2017-11-01
The enrichment method of heavy metal in water with graphite and aluminum electrode was studied, and combined with plasma restraint device for improving the sensitivity of detection and reducing the limit of detection (LOD) of elements. For aluminum electrode enrichment, the LODs of Cd, Pb and Ni can be as low as several ppb. For graphite enrichment, the measurement time can be less than 3 min. The results showed that the graphite enrichment and aluminum electrode enrichment method can effectively improve the LIBS detection ability. The graphite enrichment method combined with plasma spatial confinement is more suitable for on-line monitoring of industrial waste water, the aluminum electrode enrichment method can be used for trace heavy metal detection in water. A LIBS method and device for soil heavy metals analysis was also developed, and a mobile LIBS system was tested in outfield. The measurement results deduced from LIBS and ICP-MS had a good consistency. The results provided an important application support for rapid and on-site monitoring of heavy metals in soil. (Left: the mobile LIBS system for analysis of heavy metals in soils. Top right: the spatial confinement device. Bottom right: automatic graphite enrichment device for on0line analysis of heavy metals in water).
de Oliveira, Ricardo A G; Camargo, Fiamma; Pesquero, Naira C; Faria, Ronaldo Censi
2017-03-08
This paper describes the fabrication of 2D and 3D microfluidic paper-based analytical devices (μPADs) for monitoring glucose, total protein, and nitrite in blood serum and artificial urine. A new method of cutting and sealing filter paper to construct μPADs was demonstrated. Using an inexpensive home cutter printer soft cellulose-based filter paper was easily and precisely cut to produce pattern hydrophilic microchannels. 2D and 3D μPADs were designed with three detection zones each for the colorimetric detection of the analytes. A small volume of samples was added to the μPADs, which was photographed after 15 min using a digital camera. Both μPADs presented an excellent analytical performance for all analytes. The 2D device was applied in artificial urine samples and reached limits of detection (LODs) of 0.54 mM, 5.19 μM, and 2.34 μM for glucose, protein, and nitrite, respectively. The corresponding LODs of the 3D device applied for detecting the same analytes in artificial blood serum were 0.44 mM, 1.26 μM, and 4.35 μM. Copyright © 2017 Elsevier B.V. All rights reserved.
Liu, Jia; Guo, Jinchao; Zhang, Haibo; Li, Ning; Yang, Litao; Zhang, Dabing
2009-11-25
Various polymerase chain reaction (PCR) methods were developed for the execution of genetically modified organism (GMO) labeling policies, of which an event-specific PCR detection method based on the flanking sequence of exogenous integration is the primary trend in GMO detection due to its high specificity. In this study, the 5' and 3' flanking sequences of the exogenous integration of MON89788 soybean were revealed by thermal asymmetric interlaced PCR. The event-specific PCR primers and TaqMan probe were designed based upon the revealed 5' flanking sequence, and the qualitative and quantitative PCR assays were established employing these designed primers and probes. In qualitative PCR, the limit of detection (LOD) was about 0.01 ng of genomic DNA corresponding to 10 copies of haploid soybean genomic DNA. In the quantitative PCR assay, the LOD was as low as two haploid genome copies, and the limit of quantification was five haploid genome copies. Furthermore, the developed PCR methods were in-house validated by five researchers, and the validated results indicated that the developed event-specific PCR methods can be used for identification and quantification of MON89788 soybean and its derivates.
Liu, Xiaoxia; Tian, Miaomiao; Camara, Mohamed Amara; Guo, Liping; Yang, Li
2015-10-01
We present sequential CE analysis of amino acids and L-asparaginase-catalyzed enzyme reaction, by combing the on-line derivatization, optically gated (OG) injection and commercial-available UV-Vis detection. Various experimental conditions for sequential OG-UV/vis CE analysis were investigated and optimized by analyzing a standard mixture of amino acids. High reproducibility of the sequential CE analysis was demonstrated with RSD values (n = 20) of 2.23, 2.57, and 0.70% for peak heights, peak areas, and migration times, respectively, and the LOD of 5.0 μM (for asparagine) and 2.0 μM (for aspartic acid) were obtained. With the application of the OG-UV/vis CE analysis, sequential online CE enzyme assay of L-asparaginase-catalyzed enzyme reaction was carried out by automatically and continuously monitoring the substrate consumption and the product formation every 12 s from the beginning to the end of the reaction. The Michaelis constants for the reaction were obtained and were found to be in good agreement with the results of traditional off-line enzyme assays. The study demonstrated the feasibility and reliability of integrating the OG injection with UV/vis detection for sequential online CE analysis, which could be of potential value for online monitoring various chemical reaction and bioprocesses. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Page, G P; Amos, C I; Boerwinkle, E
1998-04-01
We present a test statistic, the quantitative LOD (QLOD) score, for the testing of both linkage and exclusion of quantitative-trait loci in randomly selected human sibships. As with the traditional LOD score, the boundary values of 3, for linkage, and -2, for exclusion, can be used for the QLOD score. We investigated the sample sizes required for inferring exclusion and linkage, for various combinations of linked genetic variance, total heritability, recombination distance, and sibship size, using fixed-size sampling. The sample sizes required for both linkage and exclusion were not qualitatively different and depended on the percentage of variance being linked or excluded and on the total genetic variance. Information regarding linkage and exclusion in sibships larger than size 2 increased as approximately all possible pairs n(n-1)/2 up to sibships of size 6. Increasing the recombination (theta) distance between the marker and the trait loci reduced empirically the power for both linkage and exclusion, as a function of approximately (1-2theta)4.
Potential linkage for schizophrenia on chromosome 22q12-q13: A replication study
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schwab, S.G.; Bondy, B.; Wildenauer, D.B.
1995-10-09
In an attempt to replicate a potential linkage on chromosome 22q12-q13.1 reported by Pulver et al., we have analyzed 4 microsatellite markers which span this chromosomal region, including the IL2RB locus, for linkage with schizophrenia in 30 families from Israel and Germany. Linkage analysis by pairwise lod score analysis as well as by multipoint analysis did not provide evidence for a single major gene locus. However, a lod score of Z{sub max} = 0.612 was obtained for a dominant model of inheritance with the marker D22S304 at recombination fraction 0.2 by pairwise analysis. In addition, using a nonparametric method, sibmore » pair analysis, a P value of 0.068 corresponding to a lod score of 0.48 was obtained for this marker. This finding, together with those of Pulver et al., is suggestive of a genetic factor in this region, predisposing for schizophrenia in a subset of families. Further studies using nonparametric methods should be conducted in order to clarify this point. 32 refs., 1 fig., 4 tabs.« less
Rommelse, Nanda N.J.; Arias-Vásquez, Alejandro; Altink, Marieke E.; Buschgens, Cathelijne J.M.; Fliers, Ellen; Asherson, Philip; Faraone, Stephen V.; Buitelaar, Jan K.; Sergeant, Joseph A.; Oosterlaan, Jaap; Franke, Barbara
2008-01-01
ADHD linkage findings have not all been consistently replicated, suggesting that other approaches to linkage analysis in ADHD might be necessary, such as the use of (quantitative) endophenotypes (heritable traits associated with an increased risk for ADHD). Genome-wide linkage analyses were performed in the Dutch subsample of the International Multi-Center ADHD Genetics (IMAGE) study comprising 238 DSM-IV combined-type ADHD probands and their 112 affected and 195 nonaffected siblings. Eight candidate neuropsychological ADHD endophenotypes with heritabilities > 0.2 were used as quantitative traits. In addition, an overall component score of neuropsychological functioning was used. A total of 5407 autosomal single-nucleotide polymorphisms (SNPs) were used to run multipoint regression-based linkage analyses. Two significant genome-wide linkage signals were found, one for Motor Timing on chromosome 2q21.1 (LOD score: 3.944) and one for Digit Span on 13q12.11 (LOD score: 3.959). Ten suggestive linkage signals were found (LOD scores ≥ 2) on chromosomes 2p, 2q, 3p, 4q, 8q, 12p, 12q, 14q, and 17q. The suggestive linkage signal for the component score that was found at 2q14.3 (LOD score: 2.878) overlapped with the region significantly linked to Motor Timing. Endophenotype approaches may increase power to detect susceptibility loci in ADHD and possibly in other complex disorders. PMID:18599010
Cha, Eunju; Kim, Sohee; Kim, Hee Won; Lee, Kang Mi; Kim, Ho Jun; Kwon, Oh-Seung; Lee, Jaeick
2016-04-01
The relationships between the ionization profile, sensitivity, and structures of 64 exogenous anabolic steroids (groups I-IV) was investigated under electrospray ionization (ESI) conditions. The target analytes were ionized as [M + H](+) or [M + H-nH2 O](+) in the positive mode, and these ions were used as precursor ions for selected reaction monitoring analysis. The collision energy and Q3 ions were optimized based on the sensitivity and selectivity. The limits of detection (LODs) were 0.05-20 ng/mL for the 64 steroids. The LODs for 38 compounds, 14 compounds and 12 compounds were in the range of 0.05-1, 2-5 and 10-20 ng/mL, respectively. Steroids including the conjugated keto-functional group at C3 showed good proton affinity and stability, and generated the [M + H](+) ion as the most abundant precursor ion. In addition, the LODs of steroids using the [M + H](+) ion as the precursor ion were mostly distributed at low concentrations. In contrast, steroids containing conjugated/unconjugated hydroxyl functional groups at C3 generated [M + H - H2 O](+) or [M + H - 2H2 O](+) ions, and these steroids showed relatively high LODs owing to poor stability and multiple ion formation. An LC-MS/MS method based on the present ionization profile was developed and validated for the determination of 78 steroids (groups I-V) in human urine. Copyright © 2015 John Wiley & Sons, Ltd.
Zhang, Qingwen; Jing, Lijing; Zhang, Jinling; Ren, Yamin; Wang, Yang; Wang, Yi; Wei, Tianxin; Liedberg, Bo
2014-10-15
A novel water-compatible macroporous molecularly imprinted film (MIF) has been developed for rapid, sensitive, and label-free detection of small molecule testosterone in urine. The MIF was synthesized by photo copolymerization of monomers (methacrylic acid [MAA] and 2-hydroxyethyl methacrylate [HEMA]), cross-linker (ethylene glycol dimethacrylate, EGDMA), and polystyrene nanoparticles (PS NPs) in combination with template testosterone molecules. The PS NPs and template molecules were subsequently removed to form an MIF with macroporous structures and the specific recognition sites of testosterone. Incubation of artificial urine and human urine on the MIF and the non-imprinted film (NIF), respectively, indicated undetectable nonspecific adsorption. Accordingly, the MIF was applied on a surface plasmon resonance (SPR) sensor for the detection of testosterone in phosphate-buffered saline (PBS) and artificial urine with a limit of detection (LOD) down to 10(-15)g/ml. To the best of our knowledge, the LOD is considered as one of the lowest among the SPR sensors for the detection of small molecules. The control experiments performed with analogue molecules such as progesterone and estradiol demonstrated the good selectivity of this MIF for sensing testosterone. Furthermore, this MIF-based SPR sensor shows high stability and reproducibility over 8months of storage at room temperature, which is more robust than protein-based biosensors. Copyright © 2014 Elsevier Inc. All rights reserved.
Sensitive paper-based analytical device for fast colorimetric detection of nitrite with smartphone.
Zhang, Xiu-Xiu; Song, Yi-Zhen; Fang, Fang; Wu, Zhi-Yong
2018-04-01
On-site rapid monitoring of nitrite as an assessment indicator of the environment, food, and physiological systems has drawn extensive attention. Here, electrokinetic stacking (ES) was combined with colorimetric reaction on a paper-based device (PAD) to achieve colorless nitrite detection with smartphone. In this paper, nitrite was stacked on the paper fluidic channel as a narrow band by electrokinetic stacking. Then, Griess reagent was introduced to visualize the stacking band. Under optimal conditions, the sensitivity of nitrite was 160-fold increased within 5 min. A linear response in the range of 0.075 to 1.0 μg mL -1 (R 2 = 0.99) and a limit of detection (LOD) of 73 ng mL -1 (0.86 μM) were obtained. The LOD was 10 times lower than the reported PAD, and close to that achieved by a desktop spectrophotometer. The applicability was demonstrated by nitrite detection from saliva and water with good selectivity, adding 100 times more concentrated co-ions. High recovery (91.0~108.7%) and reasonable intra-day and inter-day reproducibility (RSD < 9%) were obtained. This work shows that the sensitivity of colorless analyte detection-based colorimetric reaction can be effectively enhanced by integration of ES on a PAD. Graphical abstract Schematic of the experimental setups (left) and the corresponding images (right) of the actual portable device.
Nagvenkar, Anjani P; Gedanken, Aharon
2016-08-31
Nanomaterial-based enzyme mimetics (nanozymes) is an emerging field of research that promises to produce alternatives to natural enzymes for a variety of applications. The search for the most cost-effective and efficient inorganic nanomaterials, such as metal oxides, cannot be won by pristine CuO. However, unlike CuO, the Zn-doped CuO (Zn-CuO) nanoparticles reported in this paper reveal superior peroxidase-like enzyme activity. This places Zn-CuO in a good position to participate in a range of activities aimed at developing diverse enzyme applications. The peroxidase-like activity was tested and confirmed against various chromogenic substrates in the presence of H2O2 and obeyed the Michaelis-Menten enzymatic pathway. The mechanism of enhanced enzymatic activity was proved by employing terephthalic acid as a fluorescence probe and by electron spin resonance. The nanozyme, when tested for the detection of glucose, showed a substantial enhancement in the detection selectivity. The limit of detection (LOD) was also decreased reaching a limit as low as 0.27 ppm. Such a low LOD has not been reported so far for the metal oxides without any surface modifications. Moreover, the nanozyme (Zn-CuO) was utilized to detect the three antioxidants tannic acid, tartaric acid, and ascorbic acid and the relative strength of their antioxidant capacity was compared.
Eichbaum, Kathrin; Brinkmann, Markus; Buchinger, Sebastian; Reifferscheid, Georg; Hecker, Markus; Giesy, John P; Engwall, Magnus; van Bavel, Bert; Hollert, Henner
2014-07-15
Use of in vitro assays as screening tool to characterize contamination of a variety of environmental matrices has become an increasingly popular and powerful toolbox in the field of environmental toxicology. While bioassays cannot entirely substitute analytical methods such as gas chromatography-mass spectrometry (GC-MS), the increasing improvement of cell lines and standardization of bioassay procedures enhance their utility as bioanalytical pre-screening tests prior to more targeted chemical analytical investigations. Dioxin-receptor-based assays provide a holistic characterization of exposure to dioxin-like compounds (DLCs) by integrating their overall toxic potential, including potentials of unknown DLCs not detectable via e.g. GC-MS. Hence, they provide important additional information with respect to environmental risk assessment of DLCs. This review summarizes different in vitro bioassay applications for detection of DLCs and considers the comparability of bioassay and chemical analytically derived toxicity equivalents (TEQs) of different approaches and various matrices. These range from complex samples such as sediments through single reference to compound mixtures. A summary of bioassay derived detection limits (LODs) showed a number of current bioassays to be equally sensitive as chemical methodologies, but moreover revealed that most of the bioanalytical studies conducted to date did not report their LODs, which represents a limitation with regard to low potency samples. Copyright © 2014 Elsevier B.V. All rights reserved.
Wang, Yi; Wang, Yan; Ma, Aijing; Li, Dongxun; Luo, Lijuan; Liu, Dongxin; Hu, Shoukui; Jin, Dong; Liu, Kai; Ye, Changyun
2015-12-03
Here, a novel model of loop-mediated isothermal amplification (LAMP), termed multiple inner primers-LAMP (MIP-LAMP), was devised and successfully applied to detect Listeria monocytogenes. A set of 10 specific MIP-LAMP primers, which recognized 14 different regions of target gene, was designed to target a sequence in the hlyA gene. The MIP-LAMP assay efficiently amplified the target element within 35 min at 63 °C and was evaluated for sensitivity and specificity. The templates were specially amplified in the presence of the genomic DNA from L. monocytogenes. The limit of detection (LoD) of MIP-LAMP assay was 62.5 fg/reaction using purified L. monocytogenes DNA. The LoD for DNA isolated from serial dilutions of L. monocytogenes cells in buffer and in milk corresponded to 2.4 CFU and 24 CFU, respectively. The amplified products were analyzed by real-time monitoring of changes in turbidity, and visualized by adding Loop Fluorescent Detection Reagent (FD), or as a ladder-like banding pattern on gel electrophoresis. A total of 48 pork samples were investigated for L. monocytogenes by the novel MIP-LAMP method, and the diagnostic accuracy was shown to be 100% when compared to the culture-biotechnical method. In conclusion, the MIP-LAMP methodology was demonstrated to be a reliable, sensitive and specific tool for rapid detection of L. monocytogenes strains.
Detection of Ochratoxin a Using Molecular Beacons and Real-Time PCR Thermal Cycler
Sanzani, Simona Marianna; Reverberi, Massimo; Fanelli, Corrado; Ippolito, Antonio
2015-01-01
We developed a simple and cheap assay for quantitatively detecting ochratoxin A (OTA) in wine. A DNA aptamer available in literature was used as recognition probe in its molecular beacon form, i.e., with a fluorescence-quenching pair at the stem ends. Our aptabeacon could adopt a conformation allowing OTA binding, causing a fluorescence rise due to the increased distance between fluorophore and quencher. We used real-time PCR equipment for capturing the signal. With this assay, under optimized conditions, the entire process can be completed within 1 h. In addition, the proposed system exhibited a good selectivity for OTA against other mycotoxins (ochratoxin B and aflatoxin M1) and limited interference from aflatoxin B1 and patulin. A wide linear detection range (0.2–2000 µM) was achieved, with LOD = 13 nM, r = 0.9952, and R2 = 0.9904. The aptabeacon was also applied to detect OTA in red wine spiked with the same dilution series. A linear correlation with a LOD = 19 nM, r = 0.9843, and R2 = 0.9708 was observed, with recoveries in the range 63%–105%. Intra- and inter-day assays confirmed its reproducibility. The proposed biosensor, although still being finalized, might significantly facilitate the quantitative detection of OTA in wine samples, thus improving their quality control from a food safety perspective. PMID:25760080
Zainabadi, Kayvan; Adams, Matthew; Han, Zay Yar; Lwin, Hnin Wai; Han, Kay Thwe; Ouattara, Amed; Thura, Si; Plowe, Christopher V; Nyunt, Myaing M
2017-09-18
Greater Mekong Subregion countries are committed to eliminating Plasmodium falciparum malaria by 2025. Current elimination interventions target infections at parasite densities that can be detected by standard microscopy or rapid diagnostic tests (RDTs). More sensitive detection methods have been developed to detect lower density "asymptomatic" infections that may represent an important transmission reservoir. These ultrasensitive polymerase chain reaction (usPCR) tests have been used to identify target populations for mass drug administration (MDA). To date, malaria usPCR tests have used either venous or capillary blood sampling, which entails complex sample collection, processing and shipping requirements. An ultrasensitive method performed on standard dried blood spots (DBS) would greatly facilitate the molecular surveillance studies needed for targeting elimination interventions. A highly sensitive method for detecting Plasmodium falciparum and P. vivax 18S ribosomal RNA from DBS was developed by empirically optimizing nucleic acid extraction conditions. The limit of detection (LoD) was determined using spiked DBS samples that were dried and stored under simulated field conditions. Further, to assess its utility for routine molecular surveillance, two cross-sectional surveys were performed in Myanmar during the wet and dry seasons. The lower LoD of the DBS-based ultrasensitive assay was 20 parasites/mL for DBS collected on Whatman 3MM filter paper and 23 parasites/mL for Whatman 903 Protein Saver cards-equivalent to 1 parasite per 50 µL DBS. This is about 5000-fold more sensitive than standard RDTs and similar to the LoD of ≤16-22 parasites/mL reported for other ultrasensitive methods based on whole blood. In two cross-sectional surveys in Myanmar, nearly identical prevalence estimates were obtained from contemporaneous DBS samples and capillary blood samples collected during the wet and dry season. The DBS-based ultrasensitive method described in this study shows equal sensitivity as previously described methods based on whole blood, both in its limit of detection and prevalence estimates in two field surveys. The reduced cost and complexity of this method will allow for the scale-up of surveillance studies to target MDA and other malaria elimination interventions, and help lead to a better understanding of the epidemiology of low-density malaria infections.
Two types of nanoparticle-based bio-barcode amplification assays to detect HIV-1 p24 antigen.
Dong, Huahuang; Liu, Jianli; Zhu, Hong; Ou, Chin-Yih; Xing, Wenge; Qiu, Maofeng; Zhang, Guiyun; Xiao, Yao; Yao, Jun; Pan, Pinliang; Jiang, Yan
2012-08-31
HIV-1 p24 antigen is a major viral component of human immunodeficiency virus type 1 (HIV-1) which can be used to identify persons in the early stage of infection and transmission of HIV-1 from infected mothers to infants. The detection of p24 is usually accomplished by using an enzyme-linked immunosorbent assay (ELISA) with low detection sensitivity. Here we report the use of two bio-barcode amplification (BCA) assays combined with polymerase chain reaction (PCR) and gel electrophoresis to quantify HIV-1 p24 antigen. A pair of anti-p24 monoclonal antibodies (mAbs) were used in BCA assays to capture HIV-1 p24 antigen in a sandwich format and allowed for the quantitative measurement of captured p24 using PCR and gel electrophoresis. The first 1 G12 mAb was coated on microplate wells or magnetic microparticles (MMPs) to capture free p24 antigens. Captured p24 in turn captured 1D4 mAb coated gold nanoparticle probes (GNPs) containing double-stranded DNA oligonucleotides. One strand of the oligonucleotides was covalently immobilized whereas the unbound complimentary bio-barcode DNA strand could be released upon heating. The released bio-barcode DNA was amplified by PCR, electrophoresed in agarose gel and quantified. The in-house ELISA assay was found to quantify p24 antigen with a limit of detection (LOD) of 1,000 pg/ml and a linear range between 3,000 and 100,000 pg/ml. In contrast, the BCA-based microplate method yielded an LOD of 1 pg/ml and a linear detection range from 1 to 10,000 pg/ml. The BCA-based MMP method yielded an LOD of 0.1 pg/ml and a linear detection range from 0.1 to 1,000 pg/ml. When combined with PCR and simple gel electrophoresis, BCA-based microplate and MMPs assays can be used to quantify HIV-1 p24 antigen. These methods are 3-4 orders of magnitude more sensitive than our in-house ELISA-based assay and may provide a useful approach to detect p24 in patients newly infected with HIV.
Thousand-fold fluorescent signal amplification for mHealth diagnostics
Balsam, Joshua; Rasooly, Reuven; Bruck, Hugh Alan; Rasooly, Avraham
2013-01-01
The low sensitivity of Mobile Health (mHealth) optical detectors, such as those found on mobile phones, is a limiting factor for many mHealth clinical applications. To improve sensitivity, we have combined two approaches for optical signal amplification: (1) a computational approach based on an image stacking algorithm to decrease the image noise and enhance weak signals, and (2) an optical signal amplifier utilizing a capillary tube array. These approaches were used in a detection system which includes a multi-wavelength LEDs capable of exciting many fluorophores in multiple wavelengths, a mobile phone or a webcam as a detector, and capillary tube array configured with 36 capillary tubes for signal enhancement. The capillary array enables a ~100X increase in signal sensitivity for fluorescein, reducing the limit of detection (LOD) for mobile phones and webcams from 1000 nM to 10 nM. Computational image stacking enables another ~10X increase in signal sensitivity, further reducing the LOD for webcam from 10 nM to 1 nM. To demonstrate the feasibility of the device for the detection of disease-related biomarkers, Adenovirus DNA labeled with SYBR Green or fluorescein was analyzed by both our capillary array and a commercial plate reader. The LOD for the capillary array was 5ug/mL, and that of the plate reader was 1 ug/mL. Similar results were obtained using DNA stained with fluorescein. The combination of the two signal amplification approaches enables a ~1000X increase in LOD for the webcam platform. This brings it into the range of a conventional plate reader while using a smaller sample volume (10ul) than the plate reader requires (100 ul). This suggests that such a device could be suitable for biosensing applications where up to 10 fold smaller sample sizes are needed. The simple optical configuration for mHealth described in this paper employing the combined capillary and image processing signal amplification is capable of measuring weak fluorescent signals without the need of dedicated laboratories. It has the potential to be used to increase sensitivity of other optically based mHealth technologies, and may increase mHealth’s clinical utility, especially for telemedicine and for resource-poor settings and global health applications. PMID:23928092
Thousand-fold fluorescent signal amplification for mHealth diagnostics.
Balsam, Joshua; Rasooly, Reuven; Bruck, Hugh Alan; Rasooly, Avraham
2014-01-15
The low sensitivity of Mobile Health (mHealth) optical detectors, such as those found on mobile phones, is a limiting factor for many mHealth clinical applications. To improve sensitivity, we have combined two approaches for optical signal amplification: (1) a computational approach based on an image stacking algorithm to decrease the image noise and enhance weak signals, and (2) an optical signal amplifier utilizing a capillary tube array. These approaches were used in a detection system which includes multi-wavelength LEDs capable of exciting many fluorophores in multiple wavelengths, a mobile phone or a webcam as a detector, and capillary tube array configured with 36 capillary tubes for signal enhancement. The capillary array enables a ~100× increase in signal sensitivity for fluorescein, reducing the limit of detection (LOD) for mobile phones and webcams from 1000 nM to 10nM. Computational image stacking enables another ~10× increase in signal sensitivity, further reducing the LOD for webcam from 10nM to 1 nM. To demonstrate the feasibility of the device for the detection of disease-related biomarkers, adenovirus DNA labeled with SYBR green or fluorescein was analyzed by both our capillary array and a commercial plate reader. The LOD for the capillary array was 5 ug/mL, and that of the plate reader was 1 ug/mL. Similar results were obtained using DNA stained with fluorescein. The combination of the two signal amplification approaches enables a ~1000× increase in LOD for the webcam platform. This brings it into the range of a conventional plate reader while using a smaller sample volume (10 ul) than the plate reader requires (100 ul). This suggests that such a device could be suitable for biosensing applications where up to 10 fold smaller sample sizes are needed. The simple optical configuration for mHealth described in this paper employing the combined capillary and image processing signal amplification is capable of measuring weak fluorescent signals without the need of dedicated laboratories. It has the potential to be used to increase sensitivity of other optically based mHealth technologies, and may increase mHealth's clinical utility, especially for telemedicine and for resource-poor settings and global health applications. Published by Elsevier B.V.
Lorey, Martina; Adler, Belinda; Yan, Hong; Soliymani, Rabah; Ekström, Simon; Yli-Kauhaluoma, Jari; Laurell, Thomas; Baumann, Marc
2015-05-19
A new read-out method for antibody arrays using laser desorption/ionization-mass spectrometry (LDI-MS) is presented. Small, photocleavable reporter molecules with a defined mass called "mass-tags" are used for detection of immunocaptured proteins from human plasma. Using prostate specific antigen (PSA), a biomarker for prostate cancer, as a model antigen, a high sensitivity generic detection methodology based immunocapture with a primary antibody and with a biotin labeled secondary antibody coupled to mass-tagged avidin is demonstrated. As each secondary antibody can bind several avidin molecules, each having a large number of mass-tags, signal amplification can be achieved. The developed PSA sandwich mass-tag analysis method provided a limit of detection below 200 pg/mL (6 pM) for a 10 μL plasma sample, well below the clinically relevant cutoff value of 3-4 ng/mL. This brings the limit of detection (LOD) for detection of intact antigens with matrix-assisted laser desorption/ionization-mass spectrometry (MALDI-MS) down to levels comparable to capture by anti-peptide antibodies selected reaction monitoring (SISCAPA SRM) and enzyme linked immunosorbent assay (ELISA), as 6 pM corresponds to a maximal amount of 60 amol PSA captured on-spot. We propose the potential use of LDI (laser desorption/ionization) with mass-tag read-out implemented in a sandwich assay format for low abundant and/or early disease biomarker detection.
NASA Astrophysics Data System (ADS)
Lambert, S. B.; de Viron, O.; Marcus, S.
2016-12-01
El Niño events are generally accompanied by significant changes in the Earth's length-of-day (LOD) that can be explained by two approaches. Considering the angular momentum conservation of the system composed by the solid Earth and the atmosphere, ENSO events are accompanied by a strengthening of the subtropical jet streams, and, therefore, a decrease of the Earth's rotation rate. Using the torque approach, the low pressure field of the Eastern Pacific, which is close to high mountain ranges along the Western American coasts, creates a negative torque of the atmosphere on the solid Earth which tends to slow down the Earth's rotation. The large 1983 event was associated with a lengthening of the day of about 1 ms. During the 2015-2016 winter season, a major ENSO event occurred, classified as very strong by meteorological agencies. This central Pacific event, for which the Nino 3.4 index is as high as in 1983, was also concurrent with positive phases of PDO, NAO, and AAO. It coincided with an excursion of the LOD as large as 0.8 ms over a few weeks reaching its maximum around 2016 New Year. We evaluate the mountain and friction torques responsible for the Earth's rotation variations during the winter season and compare to the mean situations and to previous strong ENSO events of 1983 and 1998. Especially, we noticed that the contribution from American mountain ranges is close to the value of 1983. The weaker LOD excursion comes from an inexistent torque over the Himalayas, a weaker contribution from Europe, and a noticeable positive contribution from Antarctica. On longer time scales, core-generated ms-scale LOD excursions are found to precede NH surface and global SST fluctuations by nearly a decade; although the cause of this apparent rotational effect is not known, reported correlations of LOD and tidal-orbital forcing with surface and submarine volcanic activity offer prospects to explain these observations in a core-to-climate chain of causality.
Earthquake triggering, Earth's rotation variations, Meton's cycle and torques acting on the Earth.
NASA Astrophysics Data System (ADS)
Ostrihansky, L.
2012-04-01
In contrast to unsuccessful searching (lasting over 150 years) of correlation of earthquakes with biweekly tides the author found correlation of earthquakes with sidereal 13.66 days Earth's rotation variations expressed as the length of a day (LOD) measured daily by the International Earth's Rotation Service. After short mention about earthquakes Denali Fault Alaska 3rd November 2002, M 7.9, triggered on LOD maximum and Great Sumatra earthquake 26th December 2004 triggered on LOD minimum and the full Moon, the main object of this paper are earthquakes of period 2010-VI. 2011: Haiti M 7.0 Jan. 12, 2010 on LOD minimum, Maule Chile M 8.8 Feb. 12, 2010 on LOD maximum, Sumatra and Andaman Sea region 6 earthquakes revealed from 7 on LOD minimum, New Zealand, Christchurch M 7.1 Sep. 9, 2010 on LOD minimum and Christchurch M 6.3 Feb. 21, 2011 on LOD maximum and Japan Near coast of Honshu M 9.1 March 11, 2011 on LOD minimum. I found that LOD minimums coincide with full or new Moon only twice in a year in solstices and also twice in the year with LOD maximums in equinoxes. To prove that determined coincidences of earthquakes and LOD extremes stated above are not accidental events, histograms were constructed of earthquake occurrence and their position on LOD graph deeply in the past, in some cases from the time the IERS started to measure the Earth's rotation variations in 1962. Evaluation of histograms and the Schuster's test has proven that maxima of earthquakes are triggered always in both Earth's rotation deceleration and acceleration. Backward overview of the past earthquakes revealed that the Great Sumatra earthquake Dec. 26, 2004 had its equivalent in the shape of LOD graph, full Moon position, character of aftershocks, 19 years ago in difference only one day of Dec. 27, 1985 M 6.6, proving that not only sidereal 13.66 days variations but also the 19 years Meton's cycle is the period of the earthquakes occurrence.
An LOD with improved breakdown voltage in full-frame CCD devices
NASA Astrophysics Data System (ADS)
Banghart, Edmund K.; Stevens, Eric G.; Doan, Hung Q.; Shepherd, John P.; Meisenzahl, Eric J.
2005-02-01
In full-frame image sensors, lateral overflow drain (LOD) structures are typically formed along the vertical CCD shift registers to provide a means for preventing charge blooming in the imager pixels. In a conventional LOD structure, the n-type LOD implant is made through the thin gate dielectric stack in the device active area and adjacent to the thick field oxidation that isolates the vertical CCD columns of the imager. In this paper, a novel LOD structure is described in which the n-type LOD impurities are placed directly under the field oxidation and are, therefore, electrically isolated from the gate electrodes. By reducing the electrical fields that cause breakdown at the silicon surface, this new structure permits a larger amount of n-type impurities to be implanted for the purpose of increasing the LOD conductivity. As a consequence of the improved conductance, the LOD width can be significantly reduced, enabling the design of higher resolution imaging arrays without sacrificing charge capacity in the pixels. Numerical simulations with MEDICI of the LOD leakage current are presented that identify the breakdown mechanism, while three-dimensional solutions to Poisson's equation are used to determine the charge capacity as a function of pixel dimension.
Preechakasedkit, Pattarachaya; Pinwattana, Kulwadee; Dungchai, Wijitar; Siangproh, Weena; Chaicumpa, Wanpen; Tongtawe, Pongsri; Chailapakul, Orawon
2012-01-15
An immunochromatographic strip test using gold nanoparticles was developed for the rapid detection of Salmonella typhi (S. typhi) in human serum. The strip test based on the principle of sandwich immunoassay by the specific binding of antigens from S. typhi O901 and antibody of S. typhi O901 on a nitrocellulose membrane. Antibody-gold nanoparticle conjugate was used as the label and was coated onto a glass fiber membrane, which was used as a conjugate pad. To create a test and control zone, antibody of S. typhi O901 and an anti-IgG were dotted on the nitrocellulose membrane, respectively. Positive samples were displayed as red dots at the test and control zones of the nitrocellulose membrane, while negative samples resulted in a red dot only in the control zone. The limit of detection (LOD) was found to be 1.14×10(5) cfu mL(-1), which could be visually detected by the naked eye within 15 min. This strip test provided a lower detection limit and analysis time than a dot blot immunoassay (8.88×10(6) cfu mL(-1) for LOD and 110 min for reaction time). In addition, our immunochromatographic strip test was employed to detect S. typhi in human serum effectively, with high accuracy. This strip test offers great promise for a rapid, simple and low-cost analysis of S. typhi. Copyright © 2011 Elsevier B.V. All rights reserved.
On computation of p-values in parametric linkage analysis.
Kurbasic, Azra; Hössjer, Ola
2004-01-01
Parametric linkage analysis is usually used to find chromosomal regions linked to a disease (phenotype) that is described with a specific genetic model. This is done by investigating the relations between the disease and genetic markers, that is, well-characterized loci of known position with a clear Mendelian mode of inheritance. Assume we have found an interesting region on a chromosome that we suspect is linked to the disease. Then we want to test the hypothesis of no linkage versus the alternative one of linkage. As a measure we use the maximal lod score Z(max). It is well known that the maximal lod score has asymptotically a (2 ln 10)(-1) x (1/2 chi2(0) + 1/2 chi2(1)) distribution under the null hypothesis of no linkage when only one point (one marker) on the chromosome is studied. In this paper, we show, both by simulations and theoretical arguments, that the null hypothesis distribution of Zmax has no simple form when more than one marker is used (multipoint analysis). In fact, the distribution of Zmax depends on the number of families, their structure, the assumed genetic model, marker denseness, and marker informativity. This means that a constant critical limit of Zmax leads to tests associated with different significance levels. Because of the above-mentioned problems, from the statistical point of view the maximal lod score should be supplemented by a p-value when results are reported. Copyright (c) 2004 S. Karger AG, Basel.
The variants of an LOD of a 3D building model and their influence on spatial analyses
NASA Astrophysics Data System (ADS)
Biljecki, Filip; Ledoux, Hugo; Stoter, Jantien; Vosselman, George
2016-06-01
The level of detail (LOD) of a 3D city model indicates the model's grade and usability. However, there exist multiple valid variants of each LOD. As a consequence, the LOD concept is inconclusive as an instruction for the acquisition of 3D city models. For instance, the top surface of an LOD1 block model may be modelled at the eaves of a building or at its ridge height. Such variants, which we term geometric references, are often overlooked and are usually not documented in the metadata. Furthermore, the influence of a particular geometric reference on the performance of a spatial analysis is not known. In response to this research gap, we investigate a variety of LOD1 and LOD2 geometric references that are commonly employed, and perform numerical experiments to investigate their relative difference when used as input for different spatial analyses. We consider three use cases (estimation of the area of the building envelope, building volume, and shadows cast by buildings), and compute the deviations in a Monte Carlo simulation. The experiments, carried out with procedurally generated models, indicate that two 3D models representing the same building at the same LOD, but modelled according to different geometric references, may yield substantially different results when used in a spatial analysis. The outcome of our experiments also suggests that the geometric reference may have a bigger influence than the LOD, since an LOD1 with a specific geometric reference may yield a more accurate result than when using LOD2 models.
Banada, Padmapriya P; Deshpande, Srinidhi; Chakravorty, Soumitesh; Russo, Riccardo; Occi, James; Meister, Gabriel; Jones, Kelly J; Gelhaus, Carl H; Valderas, Michelle W; Jones, Martin; Connell, Nancy; Alland, David
2017-01-01
Francisella tularensis is a potential bioterrorism agent that is highly infectious at very low doses. Diagnosis of tularemia by blood culture and nucleic acid-based diagnostic tests is insufficiently sensitive. Here, we demonstrate a highly sensitive F. tularensis assay that incorporates sample processing and detection into a single cartridge suitable for point-of-care detection. The assay limit of detection (LOD) and dynamic range were determined in a filter-based cartridge run on the GeneXpert system. F. tularensis DNA in buffer or CFU of F. tularensis was spiked into human or macaque blood. To simulate detection in human disease, the assay was tested on blood drawn from macaques infected with F. tularensis Schu S4 at daily intervals. Assay detection was compared to that with a conventional quantitative PCR (qPCR) assay and blood culture. The assay LOD was 0.1 genome equivalents (GE) per reaction and 10 CFU/ml F. tularensis in both human and macaque blood. In infected macaques, the assay detected F. tularensis on days 1 to 4 postinfection in 21%, 17%, 60%, and 83% of macaques, respectively, compared to conventional qPCR positivity rates of 0%, 0%, 30%, and 100% and CFU detection of blood culture at 0%, 0%, 0%, and 10% positive, respectively. Assay specificity was 100%. The new cartridge-based assay can rapidly detect F. tularensis in bloodstream infections directly in whole blood at the early stages of infection with a sensitivity that is superior to that of other methods. The simplicity of the automated testing procedures may make this test suitable for rapid point-of-care detection. Copyright © 2016 American Society for Microbiology.
Foddai, A C G; Grant, I R
2017-05-01
To validate an optimized peptide-mediated magnetic separation (PMS)-phage assay for detection of viable Mycobacterium avium subsp. paratuberculosis (MAP) in milk. Inclusivity, specificity and limit of detection 50% (LOD 50 ) of the optimized PMS-phage assay were assessed. Plaques were obtained for all 43 MAP strains tested. Of 12 other Mycobacterium sp. tested, only Mycobacterium bovis BCG produced small numbers of plaques. LOD 50 of the PMS-phage assay was 0·93 MAP cells per 50 ml milk, which was better than both PMS-qPCR and PMS-culture. When individual milks (n = 146) and bulk tank milk (BTM, n = 22) obtained from Johne's affected herds were tested by the PMS-phage assay, viable MAP were detected in 31 (21·2%) of 146 individual milks and 13 (59·1%) of 22 BTM, with MAP numbers detected ranging from 6-948 plaque-forming-units per 50 ml milk. PMS-qPCR and PMS-MGIT culture proved to be less sensitive tests than the PMS-phage assay. The optimized PMS-phage assay is the most sensitive and specific method available for the detection of viable MAP in milk. Further work is needed to streamline the PMS-phage assay, because the assay's multistep format currently makes it unsuitable for adoption by the dairy industry as a screening test. The inclusivity (ability to detect all MAP strains), specificity (ability to detect only MAP) and detection sensitivity (ability to detect low numbers of MAP) of the optimized PMS-phage assay have been comprehensively demonstrated for the first time. © 2017 The Society for Applied Microbiology.
Encapsulation efficiency of CdSe/ZnS quantum dots by liposomes determined by thermal lens microscopy
Batalla, Jessica; Cabrera, Humberto; San Martín-Martínez, Eduardo; Korte, Dorota; Calderón, Antonio; Marín, Ernesto
2015-01-01
In this study the encapsulation of core shell carboxyl CdSe/ZnS quantum dots (QDs) by phospholipids liposome complexes is presented. It makes the quantum dots water soluble and photo-stable. Fluorescence self-quenching of the QDs inside the liposomes was observed. Therefore, the thermal lens microscopy (TLM) was found to be an useful tool for measuring the encapsulation efficiency of the QDs by the liposomes, for which an optimum value of 36% was determined. The obtained limit of detection (LOD) for determining QDs concentration by TLM was 0.13 nM. Moreover, the encapsulated QDs showed no prominent cytotoxicity toward Breast cancer cells line MDA-MB-231. This study was supported by UV-visible spectroscopy, high resolution transmission electron microscopy (HRTEM) and dynamic light scattering measurements (DLS). PMID:26504640
High performance liquid chromatographic assay for the quantitation of total glutathione in plasma
NASA Technical Reports Server (NTRS)
Abukhalaf, Imad K.; Silvestrov, Natalia A.; Menter, Julian M.; von Deutsch, Daniel A.; Bayorh, Mohamed A.; Socci, Robin R.; Ganafa, Agaba A.
2002-01-01
A simple and widely used homocysteine HPLC procedure was applied for the HPLC identification and quantitation of glutathione in plasma. The method, which utilizes SBDF as a derivatizing agent utilizes only 50 microl of sample volume. Linear quantitative response curve was generated for glutathione over a concentration range of 0.3125-62.50 micromol/l. Linear regression analysis of the standard curve exhibited correlation coefficient of 0.999. Limit of detection (LOD) and limit of quantitation (LOQ) values were 5.0 and 15 pmol, respectively. Glutathione recovery using this method was nearly complete (above 96%). Intra-assay and inter-assay precision studies reflected a high level of reliability and reproducibility of the method. The applicability of the method for the quantitation of glutathione was demonstrated successfully using human and rat plasma samples.
Total arsenic, mercury, lead, and cadmium contents in edible dried seaweed in Korea.
Hwang, Y O; Park, S G; Park, G Y; Choi, S M; Kim, M Y
2010-01-01
Total arsenic, mercury, lead, and cadmium contents were determined in 426 samples of seaweed sold in Korea in 2007-08. The average concentrations, expressed in mg kg(-1), dry weight, were: total arsenic 17.4 (less than the limit of detection [LOD] to 88.8), Hg 0.01 (from 0.001 to 0.050), lead 0.7 (less than the LOD to 2.7), and cadmium 0.50 (less than the LOD to 2.9). There were differences in mercury, cadmium, and arsenic content in seaweed between different kinds of products and between coastal areas. The intakes of total mercury, lead, and cadmium for Korean people from seaweed were estimated to be 0.11, 0.65, and 0.45 µg kg(-1) body weight week(-1), respectively. With respect to food safety, consumption of 8.5 g day(-1) of the samples analysed could represent up to 0.2-6.7% of the respective provisional tolerable weekly intakes established by the World Health Organization (WHO). Therefore, even if Korean people have a high consumption of seaweed, this study confirms the low probability of health risks from these metals via seaweed consumption.
Abreu, P C; Greenberg, D A; Hodge, S E
1999-09-01
Several methods have been proposed for linkage analysis of complex traits with unknown mode of inheritance. These methods include the LOD score maximized over disease models (MMLS) and the "nonparametric" linkage (NPL) statistic. In previous work, we evaluated the increase of type I error when maximizing over two or more genetic models, and we compared the power of MMLS to detect linkage, in a number of complex modes of inheritance, with analysis assuming the true model. In the present study, we compare MMLS and NPL directly. We simulated 100 data sets with 20 families each, using 26 generating models: (1) 4 intermediate models (penetrance of heterozygote between that of the two homozygotes); (2) 6 two-locus additive models; and (3) 16 two-locus heterogeneity models (admixture alpha = 1.0,.7,.5, and.3; alpha = 1.0 replicates simple Mendelian models). For LOD scores, we assumed dominant and recessive inheritance with 50% penetrance. We took the higher of the two maximum LOD scores and subtracted 0.3 to correct for multiple tests (MMLS-C). We compared expected maximum LOD scores and power, using MMLS-C and NPL as well as the true model. Since NPL uses only the affected family members, we also performed an affecteds-only analysis using MMLS-C. The MMLS-C was both uniformly more powerful than NPL for most cases we examined, except when linkage information was low, and close to the results for the true model under locus heterogeneity. We still found better power for the MMLS-C compared with NPL in affecteds-only analysis. The results show that use of two simple modes of inheritance at a fixed penetrance can have more power than NPL when the trait mode of inheritance is complex and when there is heterogeneity in the data set.
El-Ashry, S M; El-Wasseef, D R; El-Sherbiny, D T; Salem, Y A
2015-09-01
Two simple, rapid, sensitive and precise spectrophotometric and spectrofluorimetric methods were developed for the determination of indacaterol maleate in bulk powder and capsules. Both methods were based on the direct measurement of the drug in methanol. In the spectrophotometric method (Method I) the absorbance was measured at 259 nm. The absorbance-concentration plot was rectilinear over the range 1.0-10.0 µg mL(-1) with a lower detection limit (LOD) of 0.078 µg mL(-1) and lower quantification limit (LOQ) of 0.238 µg mL(-1). Meanwhile in the spectrofluorimetric method (Method II) the native fluorescence was measured at 358 nm after excitation at 258 nm. The fluorescence-concentration plot was rectilinear over the range of 1.0-40.0 ng mL(-1) with an LOD of 0.075 ng mL(-1) and an LOQ of 0.226 ng mL(-1). The proposed methods were successfully applied to the determination of indacaterol maleate in capsules with average percent recoveries ± RSD% of 99.94 ± 0.96 for Method I and 99.97 ± 0.81 for Method II. In addition, the proposed methods were extended to a content uniformity test according to the United States Pharmacopoeia (USP) guidelines and were accurate, precise for the capsules studied with acceptance value 3.98 for Method I and 2.616 for Method II. Copyright © 2015 John Wiley & Sons, Ltd.
Spherical gold nanoparticles and gold nanorods for the determination of gentamicin
NASA Astrophysics Data System (ADS)
Miranda-Andrades, Jarol R.; Pérez-Gramatges, Aurora; Pandoli, Omar; Romani, Eric C.; Aucélio, Ricardo Q.; da Silva, Andrea R.
2017-02-01
Gentamicin is an antibiotic indicated to treat mastitis in dairy cattle and for the treatment of bacterial resistance in the context of hospital infections. The effect caused by gentamicin on the optical properties of gold nanoparticles aqueous dispersions were used to develop quantitative methods to determine this antibiotic. Two different aqueous dispersions, one containing spherical Au nanoparticles (AuNPs) and the other containing Au nanorods (AuNRs), had their conditions adjusted to enable a stable and sensitive response towards gentamicin. The use of AuNPs, with measurement at 681 nm of the rising coupling plasmon band, enabled a limit of detection (LOD) of 0.4 ng mL- 1 (0.02 ng absolute LOD), ten times lower than the one achieved by measuring the decreasing of the longitudinal surface plasmon resonance band (at 662 nm). The linear analytical response of AuNPs measured at 681 nm did not require rationing of signal values to correct for linearity. Stability of the analytical response resulted in intermediary precision below 2%. No significant interference was imposed by excipients traditionally present in injectable solutions for veterinary use. Percent recoveries obtained in such formulations were between 94.5 and 98.2% regardless the existence of any difference in the proportion of the compounds known as gentamicin (C1, C1a and C2) in standard and in the samples. The method requires no derivatization with toxic reagents as usually is required in other spectroscopic approaches.
Yu, Xiantong; He, XiaoXiao; Yang, Taiqun; Zhao, Litao; Chen, Qichen; Zhang, Sanjun; Chen, Jinquan; Xu, Jianhua
2018-01-01
Dopamine (DA) is an important neurotransmitter in the hypothalamus and pituitary gland, which can produce a direct influence on mammals' emotions in midbrain. Additionally, the level of DA is highly related with some important neurologic diseases such as schizophrenia, Parkinson, and Huntington's diseases, etc. In light of the important roles that DA plays in the disease modulation, it is of considerable significance to develop a sensitive and reproducible approach for monitoring DA. The objective of this study was to develop an efficient approach to quantitatively monitor the level of DA using Ag nanoparticle (NP) dimers and enhanced Raman spectroscopy. Ag NP dimers were synthesized for the sensitive detection of DA via surface-enhanced Raman scattering (SERS). Citrate was used as both the capping agent of NPs and sensing agent to DA, which is self-assembled on the surface of Ag NP dimers by reacting with the surface carboxyl group to form a stable amide bond. To improve accuracy and precision, the multiplicative effects model for surface-enhanced Raman spectroscopy was utilized to analyze the SERS assays. A low limits of detection (LOD) of 20 pM and a wide linear response range from 30 pM to 300 nM were obtained for DA quantitative detection. The SERS enhancement factor was theoretically valued at approximately 10 7 by discrete dipole approximation. DA was self-assembled on the citrate capped surface of Ag NPs dimers through the amide bond. The adsorption energy was estimated to be 256 KJ/mol using the Langmuir isotherm model. The density functional theory was used to simulate the spectral characteristics of SERS during the adsorption of DA on the surface of the Ag dimers. Furthermore, to improve the accuracy and precision of quantitative analysis of SERS assays with a multiplicative effects model for surface-enhanced Raman spectroscopy. A LOD of 20 pM DA-level was obtained, and the linear response ranged from 30 pM to 300 nM for quantitative DA detection. The absolute relative percentage error was 4.22% between the real and predicted DA concentrations. This detection scheme is expected to have good applications in the prevention and diagnosis of certain diseases caused by disorders in the DA level.
Yu, Xiantong; He, XiaoXiao; Yang, Taiqun; Zhao, Litao; Chen, Qichen; Zhang, Sanjun; Chen, Jinquan; Xu, Jianhua
2018-01-01
Background Dopamine (DA) is an important neurotransmitter in the hypothalamus and pituitary gland, which can produce a direct influence on mammals’ emotions in midbrain. Additionally, the level of DA is highly related with some important neurologic diseases such as schizophrenia, Parkinson, and Huntington’s diseases, etc. In light of the important roles that DA plays in the disease modulation, it is of considerable significance to develop a sensitive and reproducible approach for monitoring DA. Purpose The objective of this study was to develop an efficient approach to quantitatively monitor the level of DA using Ag nanoparticle (NP) dimers and enhanced Raman spectroscopy. Methods Ag NP dimers were synthesized for the sensitive detection of DA via surface-enhanced Raman scattering (SERS). Citrate was used as both the capping agent of NPs and sensing agent to DA, which is self-assembled on the surface of Ag NP dimers by reacting with the surface carboxyl group to form a stable amide bond. To improve accuracy and precision, the multiplicative effects model for surface-enhanced Raman spectroscopy was utilized to analyze the SERS assays. Results A low limits of detection (LOD) of 20 pM and a wide linear response range from 30 pM to 300 nM were obtained for DA quantitative detection. The SERS enhancement factor was theoretically valued at approximately 107 by discrete dipole approximation. DA was self-assembled on the citrate capped surface of Ag NPs dimers through the amide bond. The adsorption energy was estimated to be 256 KJ/mol using the Langmuir isotherm model. The density functional theory was used to simulate the spectral characteristics of SERS during the adsorption of DA on the surface of the Ag dimers. Furthermore, to improve the accuracy and precision of quantitative analysis of SERS assays with a multiplicative effects model for surface-enhanced Raman spectroscopy. Conclusion A LOD of 20 pM DA-level was obtained, and the linear response ranged from 30 pM to 300 nM for quantitative DA detection. The absolute relative percentage error was 4.22% between the real and predicted DA concentrations. This detection scheme is expected to have good applications in the prevention and diagnosis of certain diseases caused by disorders in the DA level. PMID:29713165
Chericoni, S; Stefanelli, F; Iannella, V; Giusiani, M
2014-02-15
Opiates play a relevant role in forensic toxicology and their assay in urine or blood is usually performed for example in workplace drug-testing or toxicological investigation of drug impaired driving. The present work describes two new methods for detecting morphine, codeine and 6-monoacethyl morphine in human urine or blood using a single step derivatisation in aqueous phase. Propyl chloroformate is used as the dramatizing agent followed by liquid-liquid extraction and gas-chromatography-mass spectroscopy to detect the derivatives. The methods have been validated both for hydrolysed and unhydrolysed urine. For hydrolysed urine, the LOD and LOQ were 2.5ng/ml and 8.5ng/ml for codeine, and 5.2ng/ml and 15.1ng/ml for morphine, respectively. For unhydrolysed urine, the LOD and LOQ were 3.0ng/ml and 10.1ng/ml for codeine, 2.7ng/ml and 8.1ng/ml for morphine, 0.8ng/ml and 1.5ng/ml for 6-monoacetyl morphine, respectively. In blood, the LOD and LOQ were 0.44ng/ml and 1.46ng/ml for codeine, 0.29ng/ml and 0.98ng/ml for morphine, 0.15ng/ml and 0.51ng/ml for 6-monoacetyl morphine, respectively. The validated methods have been applied to 50 urine samples and 40 blood samples (both positive and negative) and they can be used in routine analyses. Copyright © 2013 Elsevier B.V. All rights reserved.
Total reflection X-ray fluorescence analysis of airborne silver nanoparticles from fabrics.
Menzel, Magnus; Fittschen, Ursula Elisabeth Adriane
2014-03-18
Ag nanoparticles (NPs) are usually applied to consumer products because of their antimicrobial properties, which are desired in fabrics for sportswear as well as cloth used for cleaning. Hazards to human health from airborne Ag NPs may occur when the NPs are inhaled. NPs are comparable in size to macromolecules and viruses and able to penetrate deep into the lungs, e.g., the alveoli, where they may cause damage to cells and tissue due to their large surface area. In this study, aerosols released form fabrics treated with Ag NPs were collected using a low pressure Berner impactor and analyzed with total reflection X-ray fluorescence (TXRF). We found that the Ag NPs are released primarily in the form of larger particles, mainly 0.13-2 μm, probably attached to fiber material. Using an electron micro probe, single particles could be identified. The detection of backscattered electrons suggests small spots on the particle consist of a heavier element, which most likely is Ag, although the signal in energy-dispersive X-ray spectroscopy (EDX) was below the lower limit of detection (LOD). To achieve LODs necessary for Ag determination, Ar peaks were eliminated by a nitrogen atmosphere provided by the "Picofox-box". This enables linear calibration and quantification of Ag. The LOD was calculated at 0.2 ng (2.0 ppb). Following the TXRF and scanning electron microscopy (SEM)/EDX analysis, the aerosol samples were dissolved in nitric acid and analyzed with ICPMS to successfully confirm the results obtained by the TXRF measurements.
Low-Cost Charged-Coupled Device (CCD) Based Detectors for Shiga Toxins Activity Analysis.
Rasooly, Reuven; Prickril, Ben; Bruck, Hugh A; Rasooly, Avraham
2017-01-01
To improve food safety there is a need to develop simple, low-cost sensitive devices for detection of food-borne pathogens and their toxins. We describe a simple, low-cost webcam-based detector which can be used for various optical detection modalities, including fluorescence, chemiluminescence, densitometry, and colorimetric assays. The portable battery-operated CCD-based detection system consists of four modules: (1) a webcam to measure and record light emission, (2) a sample plate to perform assays, (3) a light emitting diode (LED) for illumination, and (4) a portable computer to acquire and analyze images. To demonstrate the technology, we used a cell based assay for fluorescence detection of the activity of the food borne Shiga toxin type 2 (Stx2), differentiating between biologically active toxin and inactive toxin which is not a risk. The assay is based on Shiga toxin inhibition of cell protein synthesis measured through inhibition of the green fluorescent protein (GFP). In this assay, GFP emits light at 509 nm when excited with a blue LED equipped with a filter at 486 nm. The emitted light is then detected with a green filter at 535 nm. Toxin activity is measured through a reduction in the 509 nm emission. In this system the level of detection (LOD) for Stx2 was 0.1 pg/ml, similar to the LOD of commercial fluorometers. These results demonstrate the utility and potential of low cost detectors for toxin activity. This approach could be readily adapted to the detection of other food-borne toxins.
Vollbrecht, Claudia; Lehmann, Annika; Lenze, Dido; Hummel, Michael
2018-04-06
Analysis of circulating cell-free DNA (cfDNA) derived from peripheral blood ("liquid biopsy") is an attractive alternative to identify non-small cell lung cancer (NSCLC) patients with the EGFR T790M mutation eligible for 3rd generation tyrosine kinase inhibitor therapy. We evaluated two PCR-based next generation sequencing (NGS) approaches, one including unique molecular identifiers (UMI), with focus on highly sensitive EGFR T790M mutation detection. Therefore, we extracted and sequenced cfDNA from synthetic plasma samples spiked with mutated DNA at decreasing allele frequencies and from 21 diagnostic NSCLC patients. Data evaluation was performed to determine the limit of detection (LoD), accuracy, specificity and sensitivity of both assays. Considering all tested reference dilutions and mutations the UMI assay performed best in terms of LoD (1% vs. 5%), sensitivity (95.8% vs. 81.3%), specificity (100% vs. 93.8%) and accuracy (96.9% vs. 84.4%). Comparing mutation status of diagnostic samples with both assays showed 81.3% concordance with primary mutation verifiable in 52% of cases. EGFR T790M was detected concordantly in 6/7 patients with allele frequencies from 0.1% to 27%. In one patient, the T790M mutation was exclusively detectable with the UMI assay. Our data demonstrate that both assays are applicable as multi-biomarker NGS tools enabling the simultaneous detection of primary EGFR driver and resistance mutations. However, for mutations with low allelic frequencies the use of NGS panels with UMI facilitates a more sensitive and reliable detection.
Vollbrecht, Claudia; Lehmann, Annika; Lenze, Dido; Hummel, Michael
2018-01-01
Analysis of circulating cell-free DNA (cfDNA) derived from peripheral blood (“liquid biopsy”) is an attractive alternative to identify non-small cell lung cancer (NSCLC) patients with the EGFR T790M mutation eligible for 3rd generation tyrosine kinase inhibitor therapy. We evaluated two PCR-based next generation sequencing (NGS) approaches, one including unique molecular identifiers (UMI), with focus on highly sensitive EGFR T790M mutation detection. Therefore, we extracted and sequenced cfDNA from synthetic plasma samples spiked with mutated DNA at decreasing allele frequencies and from 21 diagnostic NSCLC patients. Data evaluation was performed to determine the limit of detection (LoD), accuracy, specificity and sensitivity of both assays. Considering all tested reference dilutions and mutations the UMI assay performed best in terms of LoD (1% vs. 5%), sensitivity (95.8% vs. 81.3%), specificity (100% vs. 93.8%) and accuracy (96.9% vs. 84.4%). Comparing mutation status of diagnostic samples with both assays showed 81.3% concordance with primary mutation verifiable in 52% of cases. EGFR T790M was detected concordantly in 6/7 patients with allele frequencies from 0.1% to 27%. In one patient, the T790M mutation was exclusively detectable with the UMI assay. Our data demonstrate that both assays are applicable as multi-biomarker NGS tools enabling the simultaneous detection of primary EGFR driver and resistance mutations. However, for mutations with low allelic frequencies the use of NGS panels with UMI facilitates a more sensitive and reliable detection. PMID:29719623
Development of an ultrasensitive aptasensor for the detection of aflatoxin B1.
Guo, Xiaodong; Wen, Fang; Zheng, Nan; Luo, Qiujiang; Wang, Haiwei; Wang, Hui; Li, Songli; Wang, Jiaqi
2014-06-15
Contamination of feed and food by aflatoxin B1 (AFB1), one of the most toxic of the mycotoxins, is a global concern. To prevent food safety scares, and avoid subsequent economic losses due to the recall of contaminated items, methods for the rapid, sensitive and specific detection of AFB1 at trace levels are much in demand. In this work, a simple, ultrasensitive, and reliable aptasensor is described for the detection of AFB1. An AFB1 aptamer was used as a molecular recognition probe, while its complementary DNA played a role as a signal generator for amplification by real-time quantitative polymerase chain reaction (PCR). Under optimal conditions, a wide linear detection range (5.0 × 10(-5) to 5.0 ng mL(-1)) was achieved, with a high sensitivity (limit of detection (LOD)=25 fg mL(-1)). In addition, the proposed aptasensor exhibited excellent specificity for AFB1 compared with eight other mycotoxins, with no obvious Ct value change. This aptasensor can also be used in quantifying AFB1 levels in Chinese wild rye hay samples and infant rice cereal samples, demonstrating satisfactory recoveries in the range of 88-127% and 94-119%, respectively. This detection technique has a significant potential for high-throughput, quantitative determination of mycotoxin levels in a large range of feeds and foods. Copyright © 2014 Elsevier B.V. All rights reserved.
Nguyen, Huu-Nghi; Tanaka, Mitsuru; Komabayashi, Genki; Matsui, Toshiro
2016-10-01
Matrix assisted laser desorption/ionization mass spectrometry (MALDI-MS) is widely used for the detection and analysis of ionizable compounds. However, the method has less potential for the analysis of neutral compounds, such as polyphenols, owing to their lack of favorable proton-attachment or -removal groups. In this study, we reported for the first time that nifedipine (2,6-dimethyl-3,5-dicarbomethoxy-4-(2-nitrophenyl)-1,4-dihydropyridine), which is a strong photobase generator commonly used in polymerization, can abstract protons from neutral compounds in negative mode-MALDI experiments. When nifedipine (5 mg/ml) was used as a matrix reagent, the limit of detection (LOD) for epigallocatechin-3-O-gallate (EGCG) was determined to be 100 fmol/spot, which constitutes >50-fold improvement compared to the LOD obtained when trans-3-indoleacrylic acid, a matrix reagent previously reported for polyphenol detection, was used. Of the dihydropyridines investigated, only nifedipine facilitated the detection of EGCG, suggesting that the nitrosophenyl pyridine derivative of nifedipine formed by photoreduction under laser irradiation at 355 nm plays a crucial role in detecting polyphenols in negative mode. Reduced MS detection of 5-O-methylnaringenin indicated that nifedipine may preferably remove a proton from the 5-position OH group in the A ring of the flavonoid skeleton. The significant MS detection by nifedipine was extensively observed for polyphenols including flavones, flavonones, chalcones, stilbenoids and phenolic acids. In conclusion, nifedipine can act as a novel matrix for improving polyphenol detection by MALDI-MS in negative mode. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Yang, Minghui; Sun, Steven; Kostov, Yordan
2010-01-01
There is a well-recognized need for low cost biodetection technologies for resource-poor settings with minimal medical infrastructure. Lab-on-a-chip (LOC) technology has the ability to perform biological assays in such settings. The aim of this work is to develop a low cost, high-throughput detection system for the analysis of 96 samples simultaneously outside the laboratory setting. To achieve this aim, several biosensing elements were combined: a syringe operated ELISA lab-on-a-chip (ELISA-LOC) which integrates fluid delivery system into a miniature 96-well plate; a simplified non-enzymatic reporter and detection approach using a gold nanoparticle-antibody conjugate as a secondary antibody and silver enhancement of the visual signal; and Carbon nanotubes (CNT) to increase primary antibody immobilization and improve assay sensitivity. Combined, these elements obviate the need for an ELISA washer, electrical power for operation and a sophisticated detector. We demonstrate the use of the device for detection of Staphylococcal enterotoxin B, a major foodborne toxin using three modes of detection, visual detection, CCD camera and document scanner. With visual detection or using a document scanner to measure the signal, the limit of detection (LOD) was 0.5ng/ml. In addition to visual detection, for precise quantitation of signal using densitometry and a CCD camera, the LOD was 0.1ng/ml for the CCD analysis and 0.5 ng/ml for the document scanner. The observed sensitivity is in the same range as laboratory-based ELISA testing. The point of care device can analyze 96 samples simultaneously, permitting high throughput diagnostics in the field and in resource poor areas without ready access to laboratory facilities or electricity. PMID:21503269
Yang, Litao; Xu, Songci; Pan, Aihu; Yin, Changsong; Zhang, Kewei; Wang, Zhenying; Zhou, Zhigang; Zhang, Dabing
2005-11-30
Because of the genetically modified organisms (GMOs) labeling policies issued in many countries and areas, polymerase chain reaction (PCR) methods were developed for the execution of GMO labeling policies, such as screening, gene specific, construct specific, and event specific PCR detection methods, which have become a mainstay of GMOs detection. The event specific PCR detection method is the primary trend in GMOs detection because of its high specificity based on the flanking sequence of the exogenous integrant. This genetically modified maize, MON863, contains a Cry3Bb1 coding sequence that produces a protein with enhanced insecticidal activity against the coleopteran pest, corn rootworm. In this study, the 5'-integration junction sequence between the host plant DNA and the integrated gene construct of the genetically modified maize MON863 was revealed by means of thermal asymmetric interlaced-PCR, and the specific PCR primers and TaqMan probe were designed based upon the revealed 5'-integration junction sequence; the conventional qualitative PCR and quantitative TaqMan real-time PCR detection methods employing these primers and probes were successfully developed. In conventional qualitative PCR assay, the limit of detection (LOD) was 0.1% for MON863 in 100 ng of maize genomic DNA for one reaction. In the quantitative TaqMan real-time PCR assay, the LOD and the limit of quantification were eight and 80 haploid genome copies, respectively. In addition, three mixed maize samples with known MON863 contents were detected using the established real-time PCR systems, and the ideal results indicated that the established event specific real-time PCR detection systems were reliable, sensitive, and accurate.
Earth's rotation variations and earthquakes 2010-2011
NASA Astrophysics Data System (ADS)
Ostřihanský, L.
2012-01-01
In contrast to unsuccessful searching (lasting over 150 years) for correlation of earthquakes with biweekly tides, the author found correlation of earthquakes with sidereal 13.66 days Earth's rotation variations expressed as length of a day (LOD) measured daily by International Earth's Rotation Service. After short mention about earthquakes M 8.8 Denali Fault Alaska 3 November 2002 triggered on LOD maximum and M 9.1 Great Sumatra earthquake 26 December 2004 triggered on LOD minimum and the full Moon, the main object of this paper are earthquakes of period 2010-June 2011: M 7.0 Haiti (12 January 2010 on LOD minimum, M 8.8 Maule Chile 12 February 2010 on LOD maximum, map constructed on the Indian plate revealing 6 earthquakes from 7 on LOD minimum in Sumatra and Andaman Sea region, M 7.1 New Zealand Christchurch 9 September 2010 on LOD minimum and M 6.3 Christchurch 21 February 2011 on LOD maximum, and M 9.1 Japan near coast of Honshu 11 March 2011 on LOD minimum. It was found that LOD minimums coincide with full or new Moon only twice in a year in solstices. To prove that determined coincidences of earthquakes and LOD extremes stated above are not accidental events, histograms were constructed of earthquake occurrences and their position on LOD graph deeply in the past, in some cases from the time the IERS (International Earth's Rotation Service) started to measure the Earth's rotation variations in 1962. Evaluations of histograms and the Schuster's test have proven that majority of earthquakes are triggered in both Earth's rotation deceleration and acceleration. Because during these coincidences evident movements of lithosphere occur, among others measured by GPS, it is concluded that Earth's rotation variations effectively contribute to the lithospheric plates movement. Retrospective overview of past earthquakes revealed that the Great Sumatra earthquake 26 December 2004 had its equivalent in the shape of LOD graph, full Moon position, and character of aftershocks 19 years earlier in difference only one day to 27 December 1985 earthquake, proving that not only sidereal 13.66 days variations but also that the 19 years Metons cycle is the period of the earthquakes occurrence. Histograms show the regular change of earthquake positions on branches of LOD graph and also the shape of histogram and number of earthquakes on LOD branches from the mid-ocean ridge can show which side of the ridge moves quicker.
Wang, Xiaobo; Ye, Nengsheng; Wang, Jifen; Gu, Xuexin
2010-07-01
A method was developed for the simultaneous determination of cocaine (COC) and its metabolite ecgonine methyl ester (EME) in human blood using gas chromatography-mass spectrometry (GC-MS) and gas chromatography-flame ionization detection (GC-FID). The blood sample was prepared by microwave extraction (MWE). The optimal parameters of MWE were as follows: 6 mL of chloroform-isopropanol (9: 1, v/v) mixture as extraction solvent, the pH value of the sample was adjusted at 10.0 with 0.05 mol/L Na2CO3-NaHCO3 buffer, the extraction was performed at 40 degrees C for 6 min. The COC and EME in the extract were qualified using GC-MS and quantitated using GC-FID. The average recoveries of COC and EME were from 79.91% to 99.85%, the relative standard deviations were less than 3.10%, and the limits of detection (LOD) were 60 and 40 mg/L, respectively. In the method COC and EME were detected without derivatization. The method is rapid, accurate and sensitive, and can be used for the simultaneous determination of COC and EME in blood samples.
Cabarcos, Pamela; Tabernero, María Jesús; Otero, José Luís; Míguez, Martha; Bermejo, Ana María; Martello, Simona; De Giovanni, Nadia; Chiarotti, Marcello
2014-11-01
This article presents results from 47 meconium samples, which were analyzed for fatty acid ethyl esters (FAEE) and ethyl glucuronide (EtG) for detection of gestational alcohol consumption. A validated microwave assisted extraction (MAE) method in combination with GC-MS developed in the Institute of Forensic Science (Santiago de Compostela) was used for FAEE and the cumulative concentration of ethyl myristate, ethyl palmitate and ethyl stearate with a cut-off of 600ng/g was applied for interpretation. A simple method for identification and quantification of EtG has been evaluated by ultrasonication followed solid phase extraction (SPE). Successful validation parameters were obtained for both biochemical markers of alcohol intake. FAEE and EtG concentrations in meconium ranged between values lower than LOD and 32,892ng/g or 218ng/g respectively. We have analyzed FAEE and EtG in the same meconium aliquot, enabling comparison of the efficiency of gestational ethanol exposure detection. Certain agreement between the two biomarkers was found as they are both a very specific alcohol markers, making it a useful analysis for confirmation. Copyright © 2014 Elsevier B.V. All rights reserved.
Zhu, Nuanfei; Zou, Yanmin; Huang, Menglu; Dong, Shuaibing; Wu, Xiangyang; Liang, Guoxi; Han, Zhixiang; Zhang, Zhen
2018-08-15
A sensitive and artful colorimetric immunosensor based on horseradish peroxidase (HRP) was designed by labelling metal-organic frameworks (Cu-MOFs) on the second antibody (Cu-MOFs@Ab 2 ) as signal amplification for the detection of trace dibutyl phthalate (DBP). In this system, when Cu-MOFs@Ab 2 was captured by antigen- primary antibody (Ab 1 ) complex, tremendous Cu(II) will be released from Cu-MOFs in the presence of nitric acid (HNO 3 ), and Cu(II) will be further reduced to Cu(I) after the addition of sodium ascorbate (SA), consequently, inhibiting the HRP to catalyse the colorless 3,3',5,5'-tetramethylbenzidine (TMB) into blue oxidized TMB (ox TMB). Under the optimized conditions, the limit of detection (LOD) was 1 μg L -1 , which was almost 60 times lower than that using a conventional ELISA with the same antibody. In addition, our method showed good accuracy and reproducibility (recoveries of 87.73-103.4%; CV values of 1.46-5.95%) through a spike-recovery analysis. The proposed immunosensor indicated great potential for trace DBP determination from environmental and food samples. Copyright © 2018. Published by Elsevier B.V.
Concentrations of buparvaquone in milk and tissue of dairy cows.
McDougall, S; Hillerton, J E; Pegram, D
2016-11-01
To determine the concentration of the anti-theilerial drug buparvaquone in the milk and tissue of dairy cattle following treatment with two different formulations, and to assess the effect of clinical theileriosis on the concentration of buparvaquone in milk. Healthy lactating dairy cows (n=25) were injected once (Day 0) I/M with 2.5 mg/kg of one of two formulations of buparvaquone (Butalex; n=12 or Bupaject; n=13). Milk samples were collected from all cows daily until Day 35. Five cows were slaughtered on each of Days 56, 119, 147, 203 and 328, and samples of liver, muscle and injection site tissue collected. Milk samples were also collected from cows (n=14) clinically affected with theileriosis for up to 21 days after treatment with buparvaquone. Milk and tissue samples were analysed by liquid chromatography-mass spectrometry; limits of detection (LOD) were 0.00018 mg/kg for muscle and 0.00023 mg/L for milk. Concentrations of buparvaquone in milk and tissues were log10-transformed for analysis using multivariate models. In healthy cows, concentrations of buparvaquone in milk declined with time post-treatment (p<0.001), but were above the LOD in 11 of 25 cows at Day 35. Concentration in milk was higher one day after treatment in cows treated with Butalex than in cows treated with Bupaject, but not different thereafter (p=0.007). Concentrations of buparvaquone in muscle were below the LOD for four of five animals at Day 119 and for all animals by Day 147, but were above the LOD at the injection site of one cow, and in the liver of three cows at Day 328. Tissue concentrations did not differ with formulation nor was there a formulation by time interaction (p>0.3). Concentrations of buparvaquone in the milk of clinically affected animals were not different from those of healthy animals at 1 and 21 days post-treatment (p=0.72). Between 21 and 25 days post-treatment concentrations were below the LOD in 9/14 milk samples from clinically affected cows. Detectable concentrations of buparvaquone were found in the milk of some cows for at least 35 days and in the liver and injection site of some cows until at least 328 days after injection. There were no biologically meaningful differences in milk or tissue concentrations between the formulations, or in the milk concentrations for cows that were clinically affected compared with those that were healthy at the time of treatment.
Üzer, Ayşem; Sağlam, Sener; Tekdemir, Yasemin; Ustamehmetoğlu, Belkıs; Sezer, Esma; Erçağ, Erol; Apak, Reşat
2013-10-15
Nitro-explosives contain reducible aromatic -NO2 groups or cyclic >N-NO2 bonds that may undergo reductive cleavage. This work reports the development of a cyclic voltammetric (CV) assay for nitro-aromatics (trinitrotoluene (TNT), dinitrotoluene (DNT)) and nitramines (1,3,5-trinitro-1,3,5-triazacyclohexane (RDX) and octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX)) using a glassy carbon electrode. This determination was first used for these energetic materials by resolving current responses of reduction potentials primarily due to one constituent but partly contributed by other constituents. Calibration curves of current intensity versus concentration were linear in the range of 30-120 mg L(-1) for RDX with a limit of detection (LOD) of 10.2 mg L(-1), 40-120 mg L(-1) for HMX (LOD=11.7 mg L(-1)), 40-120 mg L(-1) for TNT (LOD=11.2 mg L(-1)), and 40-140 mg L(-1) for DNT (LOD=10.8 mg L(-1)). Results showed that the CV method could provide a sensitive approach for the simultaneous determination of RDX and TNT in synthetic and real mixtures. Deconvolution of current contributions of mixtures at peak potentials of constituents was performed by multiple linear regression. The proposed method was successfully applied to the analysis of military explosives comp A5 and octol, and method validation was performed both against HPLC on a comp B (TNT+RDX) sample and against GC-MS on real post-blast residual samples containing both explosives. Copyright © 2013 Elsevier B.V. All rights reserved.
WhoKnows? Evaluating Linked Data Heuristics with a Quiz that Cleans up DBpedia
ERIC Educational Resources Information Center
Waitelonis, Jorg; Ludwig, Nadine; Knuth, Magnus; Sack, Harald
2011-01-01
Purpose: Linking Open Data (LOD) provides a vast amount of well structured semantic information, but many inconsistencies may occur, especially if the data are generated with the help of automated methods. Data cleansing approaches enable detection of inconsistencies and overhauling of affected data sets, but they are difficult to apply…
Laser-Induced Breakdown Spectroscopy of Trace Metals
NASA Technical Reports Server (NTRS)
Simons, Stephen (Technical Monitor); VanderWal, Randall L.; Ticich, Thomas M.; West, Joseph R., Jr.
2004-01-01
An alternative approach for laser-induced breakdown spectroscopy (LIBS) determination of trace metal determination in liquids is demonstrated. The limits of detection (LOD) for the technique ranged from 10 ppb to 10 ppm for 15 metals metals (Mg, Al, Si, Ca, Ti, Cr, Fe, Co, Ni, Cu, Zn, As, Cd, Hg, Pb) tested.
The research of selection model based on LOD in multi-scale display of electronic map
NASA Astrophysics Data System (ADS)
Zhang, Jinming; You, Xiong; Liu, Yingzhen
2008-10-01
This paper proposes a selection model based on LOD to aid the display of electronic map. The ratio of display scale to map scale is regarded as a LOD operator. The categorization rule, classification rule, elementary rule and spatial geometry character rule of LOD operator setting are also concluded.
Mustafa, Z; Chapman, K; Irven, C; Carr, A J; Clipsham, K; Chitnavis, J; Sinsheimer, J S; Bloomfield, V A; McCartney, M; Cox, O; Sykes, B; Loughlin, J
2000-03-01
To examine 11 candidate genes as susceptibility loci for osteoarthritis (OA). A total of 481 families have been ascertained in which at least two siblings have had joint replacement surgery of the hip, or knee, or hip and knee for idiopathic OA. Each candidate gene was targeted using one or more intragenic or closely linked microsatellite marker. The linkage data were analysed unstratified and following stratification by sex and by joint replaced (hip or knee). The analyses revealed suggestive linkage of the type IX collagen gene COL9A1 (6q12-q13) to a subset of 132 families that contained affected females who were concordant for hip OA (female-hip) with a P-value of 0.00053 and logarithm of the odds (LOD) score of 2.33 [corrected P-value of 0. 0016, corrected LOD score of 1.85]. COL9A1 may therefore be a susceptibility locus for female hip OA. In addition, there was weak evidence of linkage to HLA/COL11A2 (6p21.3) in female hip OA with a corrected P-value of 0.016.
He, Kang-Hao; Zou, Xiao-Li; Liu, Xiang; Zeng, Hong-Yan
2012-01-01
A method using reversed phase high performance liquid chromatography (RP-HPLC) coupled with diode array detector (DAD) was developed for the simultaneous determination of canthaxanthin and astaxanthin in egg yolks. Samples were extracted with acetonitrile in ultrasonic bath for 20 minutes and then purified by freezing-lipid filtration and solid phase extraction (SPE). After being vaporized to dryness by nitrogen blowing and made up to volume with methanol, the extract solution was chromatographically separated in C18 column with a unitary mobile phase consisting of acetonitrile. The proposed method was validated in terms of linearity, precision, accuracy, and limit of detection (LOD). Regression analysis revealed a good linearity between peak area of each analyte and its concentration (r > or = 0.998). The intra- and inter-day relative standard deviations (RSDs) were less than 3.6% and 5.2%, respectively. LODs of canthaxanthin and astaxanthin were 0.035 and 0.027 microg/mL (S/N = 3). The average recoveries of canthaxanthin and astaxanthin were 91.5% and 88.7%. The proposed method is simple, fast and easy to apply.
Zurynková, Pavla; Dědina, Jiří; Kratzer, Jan
2018-06-20
Atomization conditions for antimony hydride in the plasma atomizer based on a dielectric barrier discharge (DBD) with atomic absorption spectrometric detection were optimized. Argon was found as the best discharge gas under a flow rate of 50 mL min - 1 while the DBD power was optimum at 30 W. Analytical figures of merit including interference study of As, Se and Bi have been subsequently investigated and the results compared to those found in an externally heated quartz tube atomizer (QTA). The limit of detection (LOD) reached in DBD (0.15 ng mL -1 Sb) is comparable to that observed in QTA (0.14 ng mL -1 Sb). Finally, possibility of Sb preconcentration by stibane in situ trapping in a DBD atomizer was studied. For trapping time of 300 s, the preconcentration efficiency and LOD, respectively, were 103 ± 2% and 0.02 ng mL -1 . Copyright © 2018 Elsevier B.V. All rights reserved.
Significant Linkage for Tourette Syndrome in a Large French Canadian Family
Mérette, Chantal; Brassard, Andrée; Potvin, Anne; Bouvier, Hélène; Rousseau, François; Émond, Claudia; Bissonnette, Luc; Roy, Marc-André; Maziade, Michel; Ott, Jurg; Caron, Chantal
2000-01-01
Family and twin studies provide strong evidence that genetic factors are involved in the transmission of Gilles de la Tourette syndrome (TS) and related psychiatric disorders. To detect the underlying susceptibility gene(s) for TS, we performed linkage analysis in one large French Canadian family (127 members) from the Charlevoix region, in which 20 family members were definitely affected by TS and 20 others showed related tic disorders. Using model-based linkage analysis, we observed a LOD score of 3.24 on chromosome 11 (11q23). This result was obtained in a multipoint approach involving marker D11S1377, the marker for which significant linkage disequilibrium with TS recently has been detected in an Afrikaner population. Altogether, 25 markers were studied, and, for level of significance, we derived a criterion that took into account the multiple testing arising from the use of three phenotype definitions and three modes of inheritance, a procedure that yielded a LOD score of 3.18. Hence, even after adjustment for multiple testing, the present study shows statistically significant evidence for genetic linkage with TS. PMID:10986045
NASA Astrophysics Data System (ADS)
Song, Fang; Zheng, Chuantao; Yu, Di; Zhou, Yanwen; Yan, Wanhong; Ye, Weilin; Zhang, Yu; Wang, Yiding; Tittel, Frank K.
2018-03-01
A parts-per-billion in volume (ppbv) level mid-infrared methane (CH4) sensor system was demonstrated using second-harmonic wavelength modulation spectroscopy (2 f-WMS). A 3291 nm interband cascade laser (ICL) and a multi-pass gas cell (MPGC) with a 16 m optical path length were adopted in the reported sensor system. Two digital lock-in amplifier (DLIA) schemes, a digital signal processor (DSP)-based DLIA and a LabVIEW-based DLIA, were used for harmonic signal extraction. A limit of detection (LoD) of 13.07 ppbv with an averaging time of 2 s was achieved using the DSP-based DLIA and a LoD of 5.84 ppbv was obtained using the LabVIEW-based DLIA with the same averaging time. A rise time of 0→2 parts-per-million in volume (ppmv) and fall time of 2→0 ppmv were observed. Outdoor atmospheric CH4 concentration measurements were carried out to evaluate the sensor performance using the two DLIA schemes.
2005-01-01
Index IMS Ion Mobility Spectrometry IR Infrared IRE Internal Reflection Element KBr Potassium Bromide LOD Limit of Detection MS Mass Spectrometer NB...Kaiser Bryant, Master of Science in Public Health, 2005 Directed By: Peter T. LaPuma, LtCol, USAF, BSC Assistant Professor, Department of Prey Med and...hereby certifies that the use of any copyrighted material in the thesis manuscript entitled: Chemical Agent Identification Using Field-Based Attenuated
NASA Astrophysics Data System (ADS)
Song, Dan; Yang, Rong; Wang, Chongwen; Xiao, Rui; Long, Feng
2016-03-01
A novel nanosilver-deposited silica-coated Fe3O4 magnetic particle (Fe3O4@SiO2@Ag) with uniform size, good SERS activity and magnetic responsiveness was synthesized using amination polymer. The Fe3O4@SiO2@Ag magnetic particles have been successfully applied for ultrasensitive SERS detection of malachite green (MG) in water samples. The mechanism is that MG can be adsorbed on the silver surface of nanosilver-coated magnetic particles via one nitrogen atom, and the Raman signal intensity of MG is significantly enhanced by the nanosilver layer formed on the magnetic particles. The developed sensing system exhibited a sensitive response to MG in the range of 10 fM to 100 μM with a low limit of detection (LOD) 2 fM under optimal conditions. The LOD was several orders of magnitude lower than those of other methods. This SERS-based sensor showed good reproducibility and stability for MG detection. The silver-coated magnetic particles could easily be regenerated as SERS substrates only using low pH solution for multiple sensing events. The recovery of MG added to several water samples at different concentrations ranged from 90% to 110%. The proposed method facilitates the ultrasensitive analysis of dyes to satisfy the high demand for ensuring the safety of water sources.
NASA Astrophysics Data System (ADS)
Sun, Fang; Jiang, Shaoyi; Yu, Qiuming
2016-03-01
Polyethylene glycol (PEG) is widely used to modify many therapeutic proteins and nanoparticles to reduce their immunogenicity and to improve their pharmacokinetic and therapeutic properties. It is generally accepted that PEG is non-immunogenic and non-antigenic. However, an emerging of literature and studies shows that the immune system can generate specific antibodies binding PEG. These anti-PEG antibodies not only correlate with adverse reactions appeared after patient infusions, but are also found to be the reason for therapeutic efficacy loss during chronical administrations. In addition, because of constant exposure to PEG in daily consumer products including detergents, processed food and cosmetics, a substantial proportion of the population has likely developed anti-PEG immunity. Thus a method to quickly and accurately measure the anti-PEG antibody level is desired. Nevertheless, the gold standard to detect anti-PEG antibodies is ELISA, which is costly and time-consuming especially for quantification. Herein, we demonstrated the anti-PEG measurement in blood serum using surface plasmon resonance (SPR) sensor. Several PEG-based surface functionalization on SPR sensor chip were studied in terms of protein resistance and the limit of detection (LOD) of anti-PEG. The quantitative detection can be achieved in less than 30 min with LOD comparable to ELISA. Furthermore, the IgG and IgM of anti-PEG can be differentiated by following the secondary antibody.
Song, Dan; Yang, Rong; Wang, Chongwen; Xiao, Rui; Long, Feng
2016-01-01
A novel nanosilver-deposited silica-coated Fe3O4 magnetic particle (Fe3O4@SiO2@Ag) with uniform size, good SERS activity and magnetic responsiveness was synthesized using amination polymer. The Fe3O4@SiO2@Ag magnetic particles have been successfully applied for ultrasensitive SERS detection of malachite green (MG) in water samples. The mechanism is that MG can be adsorbed on the silver surface of nanosilver-coated magnetic particles via one nitrogen atom, and the Raman signal intensity of MG is significantly enhanced by the nanosilver layer formed on the magnetic particles. The developed sensing system exhibited a sensitive response to MG in the range of 10 fM to 100 μM with a low limit of detection (LOD) 2 fM under optimal conditions. The LOD was several orders of magnitude lower than those of other methods. This SERS-based sensor showed good reproducibility and stability for MG detection. The silver-coated magnetic particles could easily be regenerated as SERS substrates only using low pH solution for multiple sensing events. The recovery of MG added to several water samples at different concentrations ranged from 90% to 110%. The proposed method facilitates the ultrasensitive analysis of dyes to satisfy the high demand for ensuring the safety of water sources. PMID:26964502
Hohweyer, Jeanne; Cazeaux, Catherine; Travaillé, Emmanuelle; Languet, Emilie; Dumètre, Aurélien; Aubert, Dominique; Terryn, Christine; Dubey, Jitender P; Azas, Nadine; Houssin, Maryline; Loïc, Favennec; Villena, Isabelle; La Carbona, Stéphanie
2016-08-01
Toxoplasma gondii, Cryptosporidium spp. and Giardia intestinalis are emerging pathogen parasites in the food domain. However, without standardized methods for their detection in food matrices, parasitic foodborne outbreaks remain neglected. In this study, a new immunomagnetic separation assay (IMS Toxo) targeting the oocyst's wall of T. gondii was developed using a specific purified monoclonal antibody. Performance of this IMS Toxo coupled to microscopic and qPCR analyses was evaluated in terms of limit of detection (LOD) and recovery rate (RR) on: i) simple matrix (LOD = 5 oocysts; RR between 5 and 56%); ii) raspberries and basil (LOD = 33 oocysts/g; RR between 0.2 and 35%). Finally, to simultaneously extract the three protozoa from these food matrices, T. gondii oocysts were directly concentrated (without IMS Toxo) from the supernatant of the IMS of Cryptosporidium and Giardia (oo)cysts. This strategy associated to qPCR detection led to LOD <1 to 3 (oo)cysts/g and RR between 2 and 35%. This procedure was coupled to RT-qPCR analyses and showed that the three protozoa persisted on the leaves of basil and remained viable following storage at 4 °C for 8 days. These data strengthen the need to consider these protozoa in food safety. Copyright © 2016 Elsevier Ltd. All rights reserved.
Development of a novel tridentate ligand for colorimetric detection of Mn2+ based on AgNPs.
Wei, Jianyu; Chen, Jinfan; Yue, Guozong; Hu, Liangsheng; Zhao, Danqing; Zhu, Jing; Yang, Luming; Huang, Deshun; Zhao, Pengxiang
2018-05-09
A novel tridentate ligand nitrilotris(methylene)tris(1,2,3-triazole)triacetate (NTTTA) has been synthesized by click reaction and followed with ester hydrolysis reaction. The silver nanoparticles (AgNPs) were then modified and stabilized by this ligand, and subsequently been employed for the highly selective and sensitive colorimetric detection of Mn 2+ in aqueous solution. The presence of Mn 2+ can cause the aggregation of AgNPs, which leads to the color change of the dispersion from yellow to brown, as well as the decrease and red-shift of the surface plasmon resonance absorption. The detection limit of Mn 2+ was as approximately 0.5 μM by the naked eyes. UV-vis spectroscopy analysis showed a good linear relationship between the logarithm of the ratios (A 550 /A 395 ) and the concentration of Mn 2+ over the range of 0.05 μM-10 μM, and the LOD was calculated to be 12.6 nM (S/N = 3). The present assay showed good simplicity without the need of adjusting the pH value. The feasibility of this technique was evaluated for successful detection of Mn 2+ in tap water and lake water samples, with good recoveries. Copyright © 2018 Elsevier B.V. All rights reserved.
Braiek, Mohamed; Rokbani, Karima Bekir; Chrouda, Amani; Mrabet, Béchir; Bakhrouf, Amina; Maaref, Abderrazak; Jaffrezic-Renault, Nicole
2012-10-16
The detection of pathogenic bacteria remains a challenge for the struggle against biological weapons, nosocomial diseases, and for food safety. In this research, our aim was to develop an easy-to-use electrochemical immunosensor for the detection of pathogenic Staphylococcus aureus ATCC25923. The biosensor was elaborated by the immobilization of anti-S. aureus antibodies using a self-assembled monolayer (SAMs) of 3-Mercaptopropionic acid (MPA). These molecular assemblies were spontaneously formed by the immersion of the substrate in an organic solvent containing the SAMs that can covalently bond to the gold surface. The functionalization of the immunosensor was characterized using two electrochemical techniques: cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). Here, the analysis was performed in phosphate buffer with ferro/ferricyanide as the redox probe. The EIS technique was used for affinity assays: antibody-cell binding. A linear relationship between the increment in the electron transfer resistance (RCT) and the logarithmic value of S. aureus concentration was observed between 10 and 106 CFU/mL. The limit of detection (LOD) was observed at 10 CFU/mL, and the reproducibility was calculated to 8%. Finally, a good selectivity versus E. coli and S. epidermidis was obtained for our developed immunosensor demonstrating its specificity towards only S. aureus.
Is there a connection between Earth's core and climate at multidecadal time scales?
NASA Astrophysics Data System (ADS)
Lambert, Sébastien; Marcus, Steven; de Viron, Olivier
2017-04-01
The length-of-day (LOD) undergoes multidecadal variations of several milliseconds (ms) attributed to changes in the fluid outer core angular momentum. These variations resemble a quasi-periodic oscillation of duration 60 to 70 years, although the periodicity (and its accurate length) are disputable because of the relatively short observational time span and the lower quality of the observations before the 20th century. Interestingly, similar variations show up in various measured or reconstructed climate indices including the sea surface (SST) and surface air (SAT) temperatures. It has been shown in several studies that LOD variations lead SST and SAT variations by a few years. No clear scenarios have been raised so far to explain the link between external, astronomical forcing (e.g., Solar wind), Earth's rotation (core-driven torsional) oscillations, and Earth's surface processes (climate variations) at these time scales. Accumulating evidence, however, suggests the centrifugal tides generated by multidecadal LOD variations as a 'valve' to control the transfer of thermal energy from the lithosphere to the surface via geothermal fluxes. This hypothesis is supported by recent studies reporting significant correlations between tidal and rotational excitation and seafloor and surface volcanism. In this study, we extend recent works from us and other independent authors by re-assessing the correlations between multidecadal LOD, climate indices, Solar and magnetic activities, as well as gridded data including SST, SAT, and cloud cover. We pay a special attention to the time lags: when a significant correlation is found, the value of the lag may help to discriminate between various possible scenarios. We locate some `hot spots', particularly in the Atlantic ocean and along the trajectory of the upper branch of the Atlantic meridional overturning circulation (AMOC), where the 70-yr oscillation is strongly marked. In addition, we discuss the possibility for centrifugal tides generated by multidecadal LOD variations to activate geothermal activity on the seafloor or to affect the global conveyor belt circulation.
Abuelghar, Wessam M; Bayoumy, Hassan A; Ellaithy, Mohamed I; Khalil, Marian S
2014-04-01
To evaluate the role of different clinical, biochemical and sonographic factors as predictors of spontaneous ovulation after laparoscopic ovarian drilling (LOD) in women with clomiphene citrate resistant polycystic ovarian disease (CCR-PCOD). This prospective study recruited 251 infertile women with CCR-PCOD. Several clinical, biochemical and sonographic criteria were tested as possible predictors of spontaneous ovulation after LOD using multivariate analysis. Women with higher preoperative levels of LH, FSH and/or androstenedione had significantly higher rates of spontaneous ovulation within the first eight weeks after LOD, but only FSH and androstenedione were found to be independent predictors. Other factors including age, BMI, type of infertility, duration of infertility, menstrual pattern, testosterone level, ovarian volume and SHBG were insignificant predictors. Receiver-operating characteristic (ROC) curves derived from FSH, LH, androstenedione, and a logistic regression model showed that the best cut-off values were 4.1IU/l, 7.8IU/l, 1.2ng/ml, and 0.4897, respectively, with sensitivity of 91.18%, 100%, 73.53%, and 88.24% and specificity of 69.57%, 69.57%, 65.22%, and 73.91% for FSH, LH, androstenedione, and logistic regression model respectively. An extended follow up (9 months after LOD) was conducted for the anovulatory and the non-pregnant ovulatory women, who were treated individually according to their clinical situation. Of these women, 53.5% (69/129) got pregnant, resulting in a cumulative pregnancy rate of 48% (82/171). Of these pregnancies, 16/82 (19.5%) were spontaneous while 35.4% (29/82) and 45.1% (37/82) occurred after ovulation induction by CC and gonadotropins, respectively. This study supports the use of androstenedione, LH and FSH as a simple reliable tool in triaging patients with CCR-PCOD to select the ideal candidates for LOD. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Bruno, John G.
2014-01-01
Preliminary studies aimed at improving the sensitivity of foodborne pathogen detection via lateral flow (LF) test strips by use of high affinity DNA aptamers for capture and reporter functions when coupled to red-emitting quantum dots (Qdot 655) are reported. A variety of DNA aptamers developed against Escherichia coli, Listeria monocytogenes, and Salmonella enterica were paired in capture and reporter combinations to determine which yielded the strongest detection of their cognate bacteria using a colloidal gold screening system. Several promising sandwich combinations were identified for each of the three bacterial LF strip systems. The best E. coli aptamer-LF system was further studied and yielded a visible limit of detection (LOD) of ~3,000 E. coli 8739 and ~6,000 E. coli O157:H7 in buffer. These LODs were reduced to ~300–600 bacterial cells per test respectively by switching to a Qdot 655 aptamer-LF system. Novel aspects of these assays such as the use of high levels of detergents to avoid quantum dot agglutination and enhance migration in analytical membranes, identification of optimal analytical membrane types, UV-immobilization of capture aptamers, and novel dual biotin/digoxigenin-end labeled aptamer streptavidin-colloidal gold or -Qdot 655 conjugates plus anti-digoxigenin antibody control lines are also discussed. In general, this work provides proof-of-principle for highly sensitive aptamer-Qdot LF strip assays for rapid foodborne pathogen detection. PMID:25437803
NASA Astrophysics Data System (ADS)
Wang, Weiguo; Zou, Yake; Yan, Jinwu; Liu, Jing; Chen, Huixiong; Li, Shan; Zhang, Lei
2018-03-01
In this paper, an ultrasensitive colorimetric biosensor for human chorionic gonadotrophin (hCG) detection was designed from bottom-up method based on the dual catalysis of the horseradish peroxidase (HRP) and Au@Pt nanoparticles (NPs) relative to H2O2-TEM system. HRP and monoclonal mouse anti-hCG antibody (β-submit, mAb1) were co-immobilized onto the Au@Pt NP surface to improve catalytic efficiency and specificity, which formed a dual functionalized Au@Pt-HRP probe with the mean size of 42.8 nm (D50). The colorimetric immunoassay was developed for the hCG detection, and the Au@Pt-HRP probe featured a higher sensitivity in the concentration range of 0.4-12.8 IU L- 1 with a low limit of detection (LOD) of 0.1 IU L- 1 compared with the LODs of 0.8 IU L- 1 for BA-ELISA and of 2.0 IU L- 1 for Au@Pt, which indicated that the Au@Pt-HRP probe possessed higher catalytic efficiency with 2.8-fold increase over Au@Pt and 33.8-fold increase over HRP. Also, the Au@Pt-HRP probe exhibited good precision and reproducibility, high specificity and acceptable accuracy with CV being less than 15%. The dual functionalized Au@Pt-HRP probe as a type of signal amplified method was firstly applied in the colorimetric immunoassay for the hCG detection.
Sharma, Rekha; Dhillon, Ankita; Kumar, Dinesh
2018-03-26
The present paper reports a facile and selective colorimetric method for the detection of potential environmental and health hazardous metal ions using green synthesized silver nanoparticles (AgNPs). Here the organic functional groups present in the plant extract (Mentha arvensis) are used as reductants and stabilizers in the synthesis of AgNPs. They also provide a suitable binding site to the (Al(III)) analyte in the detection mechanism. The leaf extract of Mentha arvensis was used to synthesize AgNPs at room-temperature and at 80 °C. The AgNPs synthesized at 80 °C exhibit excellent selective colorimetric detection of Al(III). The as-synthesized AgNPs have been characterized, and the synthesis, stabilization of NPs and detection mechanism has also been illustrated by using UV-vis, XPS, FTIR, TEM, EDX, SEM, AAS, and TGA analytical tools and techniques. The selectivity of detection probe was supported by the reaction between probe and metal ions followed first-order kinetics having the highest value of the regression coefficient (R 2 = 0.99) for Al(III) and the analysis of thermodynamic parameters. The prepared sensor showed a lower limit of detection (LOD) of 1 nM (S/N = 3.2) in real water samples. The proposed method can be successfully utilized for the detection of Al(III) from both drinking and real water samples at the nanomolar level.
A comparison of LOD and UT1-UTC forecasts by different combined prediction techniques
NASA Astrophysics Data System (ADS)
Kosek, W.; Kalarus, M.; Johnson, T. J.; Wooden, W. H.; McCarthy, D. D.; Popiński, W.
Stochastic prediction techniques including autocovariance, autoregressive, autoregressive moving average, and neural networks were applied to the UT1-UTC and Length of Day (LOD) International Earth Rotation and Reference Systems Servive (IERS) EOPC04 time series to evaluate the capabilities of each method. All known effects such as leap seconds and solid Earth zonal tides were first removed from the observed values of UT1-UTC and LOD. Two combination procedures were applied to predict the resulting LODR time series: 1) the combination of the least-squares (LS) extrapolation with a stochastic predition method, and 2) the combination of the discrete wavelet transform (DWT) filtering and a stochastic prediction method. The results of the combination of the LS extrapolation with different stochastic prediction techniques were compared with the results of the UT1-UTC prediction method currently used by the IERS Rapid Service/Prediction Centre (RS/PC). It was found that the prediction accuracy depends on the starting prediction epochs, and for the combined forecast methods, the mean prediction errors for 1 to about 70 days in the future are of the same order as those of the method used by the IERS RS/PC.
Cannabis Use Surveillance by Sweat Analysis.
Gambelunghe, Cristiana; Fucci, Nadia; Aroni, Kyriaki; Bacci, Mauro; Marcelli, Antonio; Rossi, Riccardo
2016-10-01
Sweat testing, an alternative matrix for establishing drug abuse, offers additional benefits to the more common biological samples. The authors developed a procedure using gas chromatography-mass spectrometry to test for Δ9-tetrahydrocannabinol, 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid, cannabinol (CBN), and cannabidiol (CBD) in a sweat patch. The results were compared with urine and hair sample results. Urine, hair, and sweat samples were simultaneously collected from 12 patients who were involved, respectively, in forensic case and monitoring abuse. Selectivity, linearity, limit of detection (LOD), limit of quantification (LOQ), recovery, intraday and interday imprecision, and inaccuracy of the quantification procedure were validated. LODs in hair were 0.05 ng/mg for Δ9-tetrahydrocannabinol, CBN, and CBD, and 0.005 ng/mg for 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid. The LOD for sweat was 0.30 ng/patch for all substances. The LOQ in hair was 0.1 ng/mg for Δ9-tetrahydrocannabinol, CBN, and CBD, and 0.01 ng/mg for 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid. The LOQ was 0.4 ng/patch in sweat for each analyte. Cannabinoid in urine was determined by means of immunochemical screening (cutoff 11-nor-Δ-tetrahydrocannabinol-9-carboxylic acid 50 ng/mL). All subjects tested positive for 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid and Δ9-tetrahydrocannabinol in urine and hair. In sweat samples, Δ9-tetrahydrocannabinol was found in all patches (0.4-2.0 ng/patch); 6 cases were positive for CBN (0.4-0.5 ng/patch) and 3 for CBD (0.4-0.6 ng/patch); 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid was never detected in patches. Present sweat analysis results integrated the information from hair and urine and showed that sweat analysis is a suitable, noninvasive method for monitoring compliance with rehabilitation therapy and for detecting recent cumulative use of cannabinoids.
Helb, Danica; Jones, Martin; Story, Elizabeth; Boehme, Catharina; Wallace, Ellen; Ho, Ken; Kop, JoAnn; Owens, Michelle R.; Rodgers, Richard; Banada, Padmapriya; Safi, Hassan; Blakemore, Robert; Lan, N. T. Ngoc; Jones-López, Edward C.; Levi, Michael; Burday, Michele; Ayakaka, Irene; Mugerwa, Roy D.; McMillan, Bill; Winn-Deen, Emily; Christel, Lee; Dailey, Peter; Perkins, Mark D.; Persing, David H.; Alland, David
2010-01-01
Current nucleic acid amplification methods to detect Mycobacterium tuberculosis are complex, labor-intensive, and technically challenging. We developed and performed the first analysis of the Cepheid Gene Xpert System's MTB/RIF assay, an integrated hands-free sputum-processing and real-time PCR system with rapid on-demand, near-patient technology, to simultaneously detect M. tuberculosis and rifampin resistance. Analytic tests of M. tuberculosis DNA demonstrated a limit of detection (LOD) of 4.5 genomes per reaction. Studies using sputum spiked with known numbers of M. tuberculosis CFU predicted a clinical LOD of 131 CFU/ml. Killing studies showed that the assay's buffer decreased M. tuberculosis viability by at least 8 logs, substantially reducing biohazards. Tests of 23 different commonly occurring rifampin resistance mutations demonstrated that all 23 (100%) would be identified as rifampin resistant. An analysis of 20 nontuberculosis mycobacteria species confirmed high assay specificity. A small clinical validation study of 107 clinical sputum samples from suspected tuberculosis cases in Vietnam detected 29/29 (100%) smear-positive culture-positive cases and 33/39 (84.6%) or 38/53 (71.7%) smear-negative culture-positive cases, as determined by growth on solid medium or on both solid and liquid media, respectively. M. tuberculosis was not detected in 25/25 (100%) of the culture-negative samples. A study of 64 smear-positive culture-positive sputa from retreatment tuberculosis cases in Uganda detected 63/64 (98.4%) culture-positive cases and 9/9 (100%) cases of rifampin resistance. Rifampin resistance was excluded in 54/55 (98.2%) susceptible cases. Specificity rose to 100% after correcting for a conventional susceptibility test error. In conclusion, this highly sensitive and simple-to-use system can detect M. tuberculosis directly from sputum in less than 2 h. PMID:19864480
Lods, wrods, and mods: the interpretation of lod scores calculated under different models.
Hodge, S E; Elston, R C
1994-01-01
In this paper we examine the relationships among classical lod scores, "wrod" scores (lod scores calculated under the wrong genetic model), and "mod" scores (lod scores maximized over genetic model parameters). We compare the behavior of these scores when the state of nature is linkage to their behavior when the state of nature is no linkage. We describe sufficient conditions for mod scores to be valid and discuss their use to determine the correct genetic model. We show that lod scores represent a likelihood-ratio test for independence. We explain the "ascertainment-assumption-free" aspect of using mod scores to determine mode of inheritance and we set this aspect into a well-established statistical framework. Finally, we summarize practical guidelines for the use of mod scores.
The Extended Core Coax: A novel nanoarchitecture for lab-on-a-chip electrochemical diagnostics
NASA Astrophysics Data System (ADS)
Valera, Amy E.; D'Imperio, Luke; Burns, Michael J.; Naughton, Michael J.; Chiles, Thomas C.
We report a novel nanoarchitecture, the Extended Core Coax (ECC) that has applicability for the detection of biomarkers in lab-on-a-chip diagnostic devices. ECC is capable of providing accessible, highly sensitive, and specific disease diagnosis at point-of-care. The architecture represents a vertically oriented nanocoax comprised of a gold inner metal core that extends 200nm above a chrome outer metal shield, separated by a dielectric annulus. Each ECC chip contains 7 discrete sensing arrays, 0.49 mm2 in size, containing 35,000 nanoscale coaxes wired in parallel. Previous non-extended nanocoaxial architectures have demonstrated a limit of detection (LOD) of 2 ng/mL of cholera toxin using an off-chip setup. This sensitivity compares favorably to the standard optical ELISA used in clinical settings. The ECC matches this LOD, and additionally offers the benefit of specific and reliable biofunctionalization on the extended gold core. Thus, the ECC is an attractive candidate for development as a full lab-on-a-chip biosensor for detection of infectious disease biomarkers, such as cholera toxin, through tethering of biomarker recognition proteins, such as antibodies, directly on the device. Support from the National Institutes of Health (National Cancer Institute award No. CA137681 and National Institute of Allergy and Infectious Diseases award No. AI100216).
Medina-Sánchez, Mariana; Miserere, Sandrine; Cadevall, Miquell; Merkoçi, Arben
2016-02-01
In this study, we propose an electrochemical immunoassay into a disposable microfluidic platform, using quantum dots (QDs) as labels and their enhanced detection using bismuth as an alternative to mercury electrodes. CdSe@ZnS QDs were used to tag human IgG as a model protein and detected through highly sensitive stripping voltammetry of the dissolved metallic component (cadmium in our case). The modification of the screen printed carbon electrodes (SPCEs) was done by a simple electrodeposition of bismuth that was previously mixed with the sample containing QDs. A magneto-immunosandwich assay was performed using a micromixer. A magnet placed at its outlet in order to capture the magnetic beads used as solid support for the immunoassay. SPCEs were integrated at the end of the channel as detector. Different parameters such as bismuth concentration, flow rate, and incubation times, were optimized. The LOD for HIgG in presence of bismuth was 3.5 ng/mL with a RSD of 13.2%. This LOD was about 3.3-fold lower than the one obtained without bismuth. Furthermore, the sensitivity of the system was increased 100-fold respect to experiments carried out with classical screen-printed electrodes, both in presence of bismuth. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Surface plasmon resonance biosensor for the detection of ochratoxin A in cereals and beverages.
Yuan, Jing; Deng, Dawei; Lauren, Denis R; Aguilar, Marie-Isabel; Wu, Yinqiu
2009-12-10
Ochratoxins are a group of mycotoxins produced as secondary metabolites by fungi which contaminate a large variety of food and feed commodities. Due to their teratogenic and carcinogenic properties, ochratoxins present a serious hazard to human and animal health. There is an increasing need to establish a simple sensitive method to detect these toxins. Here we report a rapid and highly sensitive surface plasmon resonance (SPR) assay of ochratoxin A (OTA) using Au nanoparticles for signal enhancement on a mixed self-assembled monolayer (mSAM) surface. A competitive immunoassay format was used for the development of the OTA immunoassay, which is based on the immobilization of target OTA through its ovalbumin (OVA) conjugate with a polyethylene glycol (PEG) linker. The new OTA conjugate (OTA-PEG-OVA) showed remarkably enhanced performance characteristics compared with those based on the immobilization of a commercial bovine serum albumin BSA-OTA conjugate without a PEG linker. Although OTA concentrations as low as 1.5 ng mL(-1) could be directly detected on this surface, the limit of detection (LOD) can be dramatically improved to 0.042 ng mL(-1) for OTA by applying large gold nanoparticles (40 nm) for signal enhancement. Various chemical conditions to minimize the influence of the food matrix on assay performance were also investigated. Grain samples were simply extracted with 50% methanol and liquid samples treated with poly(vinylpyrrolidone) (PVP) (3 or 5%), without any sample clean-up or pre-concentration step prior to analysis. The LODs for OTA in oats and corn were 0.3 and 0.5 ng g(-1), respectively, while in wine and other beverages, LODs ranged from 0.058 to 0.4 ng mL(-1). No cross-reactivity was observed with three other common mycotoxins. In addition, the mSAM/OTA-PEG-OVA surface exhibited high stability with over 600 binding/regeneration cycles. This approach with simple sample preparation provides a powerful tool for the rapid and sensitive quantitative determination of OTA in food matrices.
Thomas, Jennifer L; Donnelly, Christopher C; Lloyd, Erin W; Mothershead, Robert F; Miller, Mark L
2018-03-01
An improved cleanup method has been developed for the recovery of trace levels of 12 nitro-organic explosives in soil, which is important not only for the forensic community, but also has environmental implications. A wide variety of explosives or explosive-related compounds were evaluated, including nitramines, nitrate esters, nitroaromatics, and a nitroalkane. Fortified soil samples were extracted with acetone, processed via solid phase extraction (SPE), and then analyzed by gas chromatography with electron capture detection. The following three SPE sorbents in cartridge format were compared: Empore™ SDB-XC, Oasis ® HLB, and Bond Elut NEXUS cartridges. The NEXUS cartridges provided the best overall recoveries for the 12 explosives in potting soil (average 48%) and the fastest processing times (<30min). It also rejected matrix components from spent motor oil on potting soil. The SPE method was validated by assessing limit of detection (LOD), processed sample stability, and interferences. All 12 compounds were detectable at 0.02μg explosive/gram of soil or lower in the three matrices tested (potting soil, sand, and loam) over three days. Seven explosives were stable up to seven days at 2μg/g and three were stable at 0.2μg/g, both in processed loam, which was the most challenging matrix. In the interference study, five interferences above the determined LOD for soil were detected in matrices collected across the United States and in purchased all-purpose sand, potting soil, and loam. This represented a 3.2% false positive rate for the 13 matrices processed by the screening method for interferences. The reported SPE cleanup method provides a fast and simple extraction process for separating organic explosives from matrix components, facilitating sample throughput and reducing instrument maintenance. In addition, a comparison study of the validated SPE method versus conventional syringe filtration was completed and highlighted the benefits of sample cleanup for removing matrix interferences, while also providing lower supply cost, order of magnitude lower LODs for most explosives, higher percent recoveries for complex matrices, and fewer instrument maintenance issues. Published by Elsevier B.V.
Monti, Lucia; Negri, Stefano; Meucci, Aurora; Stroppa, Angelo; Galli, Andrea; Contarini, Giovanna
2017-04-01
A chromatographic method by HPAEC-PAD was developed and in-house validated for the quantification of low sugar levels in hard cheese, specifically Grana Padano PDO cheese. Particular attention was paid to the extraction procedure, due to residual microbial and enzymatic activities. Specificity in detection and linearity were verified. Recoveries ranged from 93% for lactose to 98% for glucose and galactose. The obtained LOD and LOQ values were, respectively, 0.25 and 0.41mg/100g for lactose, 0.14 and 0.27mg/100g for galactose, and 0.16 and 0.26mg/100g for glucose. The method was applied to 59 samples of Grana Padano PDO cheese: galactose showed the highest concentration and variability among the samples (1.36±0.89), compared to both lactose (0.45±0.12) and glucose (0.46±0.13). Considering the very low levels of sugars detected, authentic PDO Grana Padano could be safely included in the diet of people suffering from lactose intolerance. Copyright © 2016 Elsevier Ltd. All rights reserved.
An instrument-free, screen-printed paper microfluidic device that enables bio and chemical sensing.
Mohammadi, Saeed; Maeki, Masatoshi; Mohamadi, Reza M; Ishida, Akihiko; Tani, Hirofumi; Tokeshi, Manabu
2015-10-07
This paper describes a simple and instrument-free screen-printing method to fabricate hydrophilic channels by patterning polydimethylsiloxane (PDMS) onto chromatography paper. Clearly recognizable border lines were formed between hydrophilic and hydrophobic areas. The minimum width of the printed channel to deliver an aqueous sample was 600 μm, as obtained by this method. Fabricated microfluidic paper-based analytical devices (μPADs) were tested for several colorimetric assays of pH, glucose, and protein in both buffer and artificial urine samples and results were obtained in less than 30 min. The limits of detection (LODs) for glucose and bovine serum albumin (BSA) were 5 mM and 8 μM, respectively. Furthermore, the pH values of different solutions were visually recognised with the naked eye by using a sensitive ink. Ultimately, it is expected that this PDMS-screen-printing (PSP) methodology for μPADs can be readily translated to other colorimetric detection and hydrophilic channels surrounded by a hydrophobic polymer can be formed to transport fluids toward target zones.
Heydari, Rouhollah; Hosseini, Mohammad; Zarabi, Sanaz
2015-01-01
In this paper, a simple and cost effective method was developed for extraction and pre-concentration of carmine in food samples by using cloud point extraction (CPE) prior to its spectrophotometric determination. Carmine was extracted from aqueous solution using Triton X-100 as extracting solvent. The effects of main parameters such as solution pH, surfactant and salt concentrations, incubation time and temperature were investigated and optimized. Calibration graph was linear in the range of 0.04-5.0 μg mL(-1) of carmine in the initial solution with regression coefficient of 0.9995. The limit of detection (LOD) and limit of quantification were 0.012 and 0.04 μg mL(-1), respectively. Relative standard deviation (RSD) at low concentration level (0.05 μg mL(-1)) of carmine was 4.8% (n=7). Recovery values in different concentration levels were in the range of 93.7-105.8%. The obtained results demonstrate the proposed method can be applied satisfactory to determine the carmine in food samples. Copyright © 2015 Elsevier B.V. All rights reserved.
Alkaline phosphatase labeled SERS active sandwich immunoassay for detection of Escherichia coli
NASA Astrophysics Data System (ADS)
Bozkurt, Akif Goktug; Buyukgoz, Guluzar Gorkem; Soforoglu, Mehmet; Tamer, Ugur; Suludere, Zekiye; Boyaci, Ismail Hakki
2018-04-01
In this study, a sandwich immunoassay method utilizing enzymatic activity of alkaline phosphatase (ALP) on 5-bromo-4-chloro-3-indolyl phosphate (BCIP) for Escherichia coli (E. coli) detection was developed using surface enhanced Raman spectroscopy (SERS). For this purpose, spherical magnetic gold coated core-shell nanoparticles (MNPs-Au) and rod shape gold nanoparticles (Au-NRs) were synthesized and modified for immunomagnetic separation (IMS) of E. coli from the solution. In order to specify the developed method to ALP activity, Au-NRs were labeled with this enzyme. After successful construction of the immunoassay, BCIP substrate was added to produce the SERS-active product; 5-bromo-4-chloro-3-indole (BCI). A good linearity (R2 = 0.992) was established between the specific SERS intensity of BCI at 600 cm- 1 and logarithmic E. coli concentration in the range of 1.7 × 101-1.7 × 106 cfu mL- 1. LOD and LOQ values were also calculated and found to be 10 cfu mL- 1 and 30 cfu mL- 1, respectively.
López-Muñoz, Gerardo A; Estévez, M-Carmen; Vázquez-García, Marc; Berenguel-Alonso, Miguel; Alonso-Chamarro, Julián; Homs-Corbera, Antoni; Lechuga, Laura M
2018-05-01
Ultrasmooth gold/silver/gold trilayer nanostructured plasmonic sensors were obtained using commercial Blu-ray optical discs as nanoslits-based flexible polymer substrates. A thin gold film was used as an adhesion and nucleation layer to improve the chemical stability and reduce the surface roughness of the overlying silver film, without increasing ohmic plasmon losses. The structures were physically and optically characterized and compared with nanostructures of single gold layer. Ultrasmooth and chemically stable trilayer nanostructures with a surface roughness <0.5 nm were obtained following a simple and reproducible fabrication process. They showed a figure of merit (FOM) value up to 69.2 RIU -1 which is significantly higher (more than 95%) than the gold monolayer counterpart. Their potential for biosensing was demonstrated by employing the trilayer sensor for the direct and refractometric (label-free) detection of C-reactive protein (CRP) biomarker in undiluted urine achieving a Limit of Detection (LOD) in the pM order. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Páscoa, Ricardo N M J; Tóth, Ildikó V; Rangel, António O S S
2011-06-15
This work exploits a multi-syringe injection analysis (MSFIA) system coupled with a long liquid waveguide capillary cell for the spectrophotometric determination of zinc and copper in waters. A liquid waveguide capillary cell (1.0m pathlength, 550 μm i.d. and 250 μL internal volume) was used to enhance the sensitivity of the detection. The determination for both ions is based on a colorimetric reaction with zincon at different pH values. The developed methodology compares favourably with other previously described procedures, as it allows to reach low detection limits for both cations (LODs of 0.1 and 2 μg L(-1), for copper and zinc, respectively), without the need for any pre-concentration step. The system also provided a linear response up to 100 μg L(-1) with a high throughput (43 h(-1)) and low reagent consumption and effluent production. The developed work was applied to natural waters and three certified reference water samples. Copyright © 2011 Elsevier B.V. All rights reserved.
Park, Joonhong; Song, Minsik; Jang, Woori; Chae, Hyojin; Lee, Gun Dong; Kim, KyungTak; Park, Heekyung; Kim, Myungshin; Kim, Yonggoo
2017-02-01
We developed and evaluated the feasibility of peptide nucleic acid (PNA)-based fluorescence melting curve analysis (FMCA) to detect common mutations in myeloproliferative neoplasms (MPNs). We have set up two separate reactions of PNA-based FMCA: JAK2 V617F &CALR p.Leu367fs*46 (set A) and MPL W515L/K &CALR p.Lys385fs*47 (set B). Clinical usefulness was validated with allele-specific real-time PCR, fragment analysis, Sanger sequencing in 57 BCR-ABL1-negative MPNs. The limit of detection (LOD) of PNA-based FMCA was approximately 10% for each mutation and interference reactions using mixtures of different mutations were not observed. Non-specific amplification was not observed in normal control. PNA-based FMCA was able to detect all JAK2 V617F (n=20), CALR p.Leu367fs*46 (n=10) and p.Lys385fs*47 (n=8). Three of six MPL mutations were detected except three samples with low mutant concentration in out of LOD. JAK2 exon 12 mutations (n=7) were negative without influencing V617F results. Among six variant CALR exon 9 mutations, two were detected by this method owing to invading of probe binding site. PNA-based FMCA for detecting common JAK2, MPL, and CALR mutations is a rapid, simple, and sensitive technique in BCR-ABL1-negative MPNs with >10% mutant allele at the time of initial diagnosis. Copyright © 2016 Elsevier B.V. All rights reserved.
Enhancing the Detection of Giardia duodenalis Cysts in Foods by Inertial Microfluidic Separation
Ganz, Kyle R.; Clime, Liviu; Farber, Jeffrey M.; Corneau, Nathalie
2015-01-01
The sensitivity and specificity of current Giardia cyst detection methods for foods are largely determined by the effectiveness of the elution, separation, and concentration methods used. The aim of these methods is to produce a final suspension with an adequate concentration of Giardia cysts for detection and a low concentration of interfering food debris. In the present study, a microfluidic device, which makes use of inertial separation, was designed and fabricated for the separation of Giardia cysts. A cyclical pumping platform and protocol was developed to concentrate 10-ml suspensions down to less than 1 ml. Tests involving Giardia duodenalis cysts and 1.90-μm microbeads in pure suspensions demonstrated the specificity of the microfluidic chip for cysts over smaller nonspecific particles. As the suspension cycled through the chip, a large number of beads were removed (70%) and the majority of the cysts were concentrated (82%). Subsequently, the microfluidic inertial separation chip was integrated into a method for the detection of G. duodenalis cysts from lettuce samples. The method greatly reduced the concentration of background debris in the final suspensions (10-fold reduction) in comparison to that obtained by a conventional method. The method also recovered an average of 68.4% of cysts from 25-g lettuce samples and had a limit of detection (LOD) of 38 cysts. While the recovery of cysts by inertial separation was slightly lower, and the LOD slightly higher, than with the conventional method, the sample analysis time was greatly reduced, as there were far fewer background food particles interfering with the detection of cysts by immunofluorescence microscopy. PMID:25841016
Wang, Jun-liang; Xia, Qing; Zhang, An-ping; Hu, Xiao-yan; Lin, Chun-mian
2012-01-01
The widespread use of organophosphorus pesticides (OPs) poses a great threat to human health and has made the detection of OP residues in food an important task, especially in view of the fact that easy and rapid detection methods are needed. Because OPs have inhibitory effects on the activity of α-naphthyl acetate esterase (ANAE) in plants, in this work we evaluated the possibility of detecting OPs in vegetables with ANAE extracted from commercial flour. The limits of detection (LODs) obtained for methamidophos, dichlorvos, phoxim, dimethoate, and malathion in lettuce samples with crude ANAE were 0.17, 0.11, 0.11, 0.96, and 1.70 mg/kg, respectively. Based on the maximum residue limits (MRLs) for OPs in food stipulated by Chinese laws which are 0.05, 0.20, 0.05, 1.00, and 8.00 mg/kg for methamidophos, dichlorvos, phoxim, dimethoate, and malathion, respectively, the esterase inhibition method with crude ANAE had sufficient sensitivity to detect the residues of dichlorvos, dimethoate, and malathion in lettuce, but it could not be used to guarantee the safety of the same samples if methamidophos or phoxim residue was present. The sensitivity of the method was improved by the use of esterase purified by ammonium sulfate salting-out. The LODs obtained for methamidophos and phoxim with purified esterase were lower than the MRLs for these OPs in food. This is a very promising method for the detection of OP residues in vegetables using crude or purified esterase because of its cheapness, sensitivity, and convenience. PMID:22467368
A SPR-based immunosensor for the detection of isoproturon.
Gouzy, Marie-Françoise; Kess, Melanie; Krämer, Petra M
2009-02-15
The proof of principle of a reusable surface plasmon resonance (SPR)-based immunosensor for the monitoring of isoproturon (IPU), a selective and systemic herbicide, is presented. The detecting rat monoclonal anti-isoproturon antibody (mAb IOC 7E1) was reversibly immobilized through the use of a capture mouse anti-rat (kappa-chain) monoclonal antibody (mAb TIB 172), which was covalently immobilized on the sensor chip surface. Such strategy features a controlled binding of the captured detecting antibody as well as facilitates the surface regeneration. The capture of the anti-IPU mAb by the antibody (TIB 172) coated sensor surface could be carried out up to 120 times (immobilization/regeneration cycles) without any evidence of activity loss. With a high test midpoint and a low associated SPR signal, the direct detection format was shown to be unsuitable for the routine analysis of isoproturon. However, the limit of detection (LOD) could be easily enhanced by using a strategy based on a surface competition assay, which improved all immunosensor parameters. Moreover, the sensitivity and working range of the indirect format were found to be dependent on the surface density of the anti-IPU mAb IOC 7E1. As expected for competitive formats, the lowest surface coverage (0.5 ng/mm(2)) allowed a lower detection of the herbicide isoproturon with a calculated LOD of 0.1 microg/l, an IC(50) (50% inhibition) of 5.3+/-0.6 microg/l, and a working range (20-80% inhibition) of 1.3-16.3 microg/l.
Sharma, Arati; Kumar, A; Khan, Raju
2017-07-01
Gold nanoparticles (Au-NPs) functionalized Poly (3,4-ethylenedioxythiophene) (PEDOT) bioelectrodes were fabricated layer by layer deposition on ITO electrode for detection of aflatoxin B 1 . The monoclonal anti-aflatoxin antibodies (Anti-AFB 1 ) were immobilized over the surface of PEDOT/Au-NPs/ITO using EDC/NHS coupling. The surface morphology and characteristics of the modified electrodes were investigated by scanning electron microscope and contact angle measurements. The electrochemical analysis of the fabricated immunoelectrode and the immobilization of the antibodies have been evaluated and confirmed by performing Cyclic Voltammetry (CV), Electrochemical Impedance Spectroscopy (EIS) and Fourier Transform Infrared Spectroscopy (FTIR). Decrease in the value of electron transfer resistance (R et ) and increase in the peak current values after incorporation of Au-NPs signifies the enhanced properties of PEDOT embedded Au-NPs. The heterogeneous rate constant (k s ) and transfer coefficient (α) have been determined by using Laviron's method. The fabricated immunosensor exhibits high sensitive amperometric response of 3.72μAngmL -1 towards AFB 1 concentration in a linear range of 1-25ngmL -1 with detection limit (LOD) of 0.0045ngmL -1 and limit of quantification (LOQ) of 0.0156ngmL -1 . The fabricated immunoelectrode shows a reproducibility of 96.13% and 94.5% towards real maize sample spiked with AFB 1 of concentration 30ngmL -1 and 50ngmL -1 , respectively. Copyright © 2017 Elsevier B.V. All rights reserved.
Narang, Jagriti; Singhal, Chaitali; Malhotra, Nitesh; Narang, Sumit; Pn, Anoop Krishna; Gupta, Riya; Kansal, Ruby; Pundir, C S
2016-12-15
Nanocrystals of zeolites (Nanocrys Zeo) and Multi-walled carbon nanotubes (MWCNT) based diagnostic genosensor was employed for detection of polymerase chain (PCR) amplified HBVDNA in blood of hepatitis B patients. The ssDNA-nanocomposite modified electrode was characterized by cyclic voltammetry (CV), differential pulse voltammetry (DPV) and electrochemical impedance spectroscopy (EIS). The hybridization between ss DNA probe and target ss DNA was detected by reduction in current, generated by interaction of methylene blue (MB) with free guanine (3'G) of ssDNA. Nanocrys zeo were deposited on the Fluorine doped tin oxide glass electrode (FTO) by drop-casting method for better immobilization of ss DNA while MWCNTs are incorporated into the zeolite-assembly to enhance the electro-conductivity of the present genosensor. The ssDNA-nanocomposite modified FTO electrode exhibited optimum current within 5s, at pH 5.6, and incubation temperature of 45°C. The value of charge transfer resistance (Rct) was linear with the number of copies of target DNA between 150 and 10(6) copies/ml. The limit of detection (LOD) of the sensor was 50 copies/ml. Within and between batches coefficients of variation (CV) were 2.5% and 3.2% respectively. Results obtained with our genosensor were also correlated with those by RT-PCR and r(2) value found with good accuracy of 97%. The electrode was reused by dipping it into 0.1M NaOH for 3min and lost 50% of its initial activity in 4 weeks. Furthermore the technique employed for detection of HBV is EIS, which is convenient and required less analysis time. Copyright © 2016 Elsevier B.V. All rights reserved.
Huppertz, Laura M; Kneisel, Stefan; Auwärter, Volker; Kempf, Jürgen
2014-02-01
Considering the vast variety of synthetic cannabinoids and herbal mixtures - commonly known as 'Spice' or 'K2' - on the market and the resulting increase of severe intoxications related to their consumption, there is a need in clinical and forensic toxicology for comprehensive up-to-date screening methods. The focus of this project aimed at developing and implementing an automated screening procedure for the detection of synthetic cannabinoids in serum using a liquid chromatography-ion trap-MS (LC-MS(n)) system and a spectra library-based approach, currently including 46 synthetic cannabinoids and 8 isotope labelled analogues. In the process of method development, a high-temperature ESI source (IonBooster(TM), Bruker Daltonik) and its effects on the ionization efficiency of the investigated synthetic cannabinoids were evaluated and compared to a conventional ESI source. Despite their structural diversity, all investigated synthetic cannabinoids benefitted from high-temperature ionization by showing remarkably higher MS intensities compared to conventional ESI. The employed search algorithm matches retention time, MS and MS(2)/MS(3) spectra. With the utilization of the ionBooster source, limits for the automated detection comparable to cut-off values of routine MRM methods were achieved for the majority of analytes. Even compounds not identified when using a conventional ESI source were detected using the ionBooster-source. LODs in serum range from 0.1 ng/ml to 0.5 ng/ml. The use of parent compounds as analytical targets offers the possibility of instantly adding new emerging compounds to the library and immediately applying the updated method to serum samples, allowing the rapid adaptation of the screening method to ongoing forensic or clinical requirements. The presented approach can also be applied to other specimens, such as oral fluid or hair, and herbal mixtures and was successfully applied to authentic serum samples. Quantitative MRM results of samples with analyte concentrations above the determined LOD were confirmed as positive findings by the presented method. Copyright © 2014 John Wiley & Sons, Ltd.
Pérez-Ruiz, Elena; Decrop, Deborah; Ven, Karen; Tripodi, Lisa; Leirs, Karen; Rosseels, Joelle; van de Wouwer, Marlies; Geukens, Nick; De Vos, Ann; Vanmechelen, Eugeen; Winderickx, Joris; Lammertyn, Jeroen; Spasic, Dragana
2018-07-26
The close correlation between Tau pathology and Alzheimer's disease (AD) progression makes this protein a suitable biomarker for diagnosis and monitoring of the disorder evolution. However, the use of Tau in diagnostics has been hampered, as it currently requires collection of cerebrospinal fluid (CSF), which is an invasive clinical procedure. Although measuring Tau-levels in blood plasma would be favorable, the concentrations are below the detection limit of a conventional ELISA. In this work, we developed a digital ELISA for the quantification of attomolar protein Tau concentrations in both buffer and biological samples. Individual Tau molecules were first captured on the surface of magnetic particles using in-house developed antibodies and subsequently isolated into the femtoliter-sized wells of a 2 × 2 mm 2 microwell array. Combination of high-affinity antibodies, optimal assay conditions and a digital quantification approach resulted in a 24 ± 7 aM limit of detection (LOD) in buffer samples. Additionally, a dynamic range of 6 orders of magnitude was achieved by combining the digital readout with an analogue approach, allowing quantification from attomolar to picomolar levels of Tau using the same platform. This proves the compatibility of the presented assay with the wide range of Tau concentrations encountered in different biological samples. Next, the developed digital assay was applied to detect total Tau levels in spiked blood plasma. A similar LOD (55 ± 29 aM) was obtained compared to the buffer samples, which was 5000-fold more sensitive than commercially available ELISAs and even outperformed previously reported digital assays with 10-fold increase in sensitivity. Finally, the performance of the developed digital ELISA was assessed by quantifying protein Tau in three clinical CSF samples. Here, a high correlation (i.e. Pearson coefficient of 0.99) was found between the measured percentage of active particles and the reference protein Tau values. The presented digital ELISA technology has great capacity in unlocking the potential of Tau as biomarker for early AD diagnosis. Copyright © 2018 Elsevier B.V. All rights reserved.
Guan, Wenna; Zhu, Tao; Wang, Yuejie; Zhang, Zhongyi; Jin, Zhao; Wang, Cong; Bai, Fali
2016-09-01
Hydrocarbons are widespread in cyanobacteria, and the biochemical synthetic pathways were recently identified. Intracellular fatty alka(e)nes of cyanobacteria have been detected by liquid-liquid extraction (LLE) coupled to gas chromatography-mass spectrometry (GC/MS). However, whether fatty alka(e)nes can be released to cyanobacterial culture media remains to be clarified. This work develops a sensitive method for analyzing the trace level of extracellular hydrocarbons in cyanobacterial culture media by head space solid-phase microextraction (HS-SPME) coupled to GC/MS. Headspace (HS) extraction mode using polydimethylsiloxane fiber to extract for 30min at 50°C was employed as the optimal extraction conditions. Five cyanobacterial fatty alka(e)nes analogs including pentadecene (C15:1), pentadecane (C15:0), heptadecene (C17:1), heptadecane (C17:0), nonadecane (C19:0) were analyzed, and the data obtained from HS-SPME-GC/MS method were quantified using internal standard peak area comparisons. Limits of detection (LOD), limits of quantitation (LOQ), linear dynamic range, precisions (RSD) and recovery for the analysis of extracellular fatty alka(e)nes of cyanobacteria by HS-SPME-GC/MS were evaluated. The LODs limits of detection (S/N = 3) varied from 10 to 21 ng L-1. The correlation coefficients (r) of the calibration curves ranged from 0.9873 to 0.9977 with a linearity from 0.1 to 50 μg L-1. The RSD values were ranging from 7.8 to 14.0% and from 4.0 to 8.8% at 1.0 μg L-1 and 10.0 μg L-1 standard solutions, respectively. Comparative analysis of extracellular fatty alka(e)nes in the culture media of model cyanobacteria Synechocystis sp. PCC 6803 demonstrated that sensitivity of HS-SPME-GC/MS method was significantly higher than LLE method. Finally, we found that heptadecane can be released into the culture media of Synechocystis sp. PCC 6803 at the later growth period. Copyright © 2016 Elsevier B.V. All rights reserved.
da Costa, Marion Pereira; Frasao, Beatriz da Silva; Lima, Bruno Reis Carneiro da Costa; Rodrigues, Bruna Leal; Conte Junior, Carlos Adam
2016-05-15
During yogurt manufacture, the lactose fermentation and organic acid production can be used to monitor the fermentation process by starter cultures and probiotic bacteria. In the present work, a simple, sensitive and reproducible high-performance liquid chromatography with dual detectors, diode array detector and refractive index was validated by simultaneous analysis of carbohydrates and organic acids in goat milk yogurts. In addition, pH and bacterial analysis were performed. Separation of all the compounds was performed on an Aminex HPX-87H column (300×7.8 mm, 9 µm) utilizing a 3 mmol L(-1) sulfuric acid aqueous mobile phase under isocratic conditions. Lactose, glucose, galactose, citric, lactic and formic acids were used to evaluate the following performance parameters: selectivity, linearity, precision, limit of detection (LOD), limit of quantification (LOQ), decision limits (CCα), detection capabilities (CCβ), recovery and robustness. For the method application a six goat milk yogurts were elaborated: natural, probiotic, prebiotic, symbiotic, cupuassu fruit pulp, and probiotic with cupuassu fruit pulp. The validated method presented an excellent selectivity with no significant matrix effect, and a broad linear study range with coefficients of determination higher than 0.995. The relative standard deviation was lower than 10% under repeatability and within-laboratory reproducibility conditions for the studied analytes. The LOD of the method was defined from 0.001 to 0.003 µg g(-1), and the LOQ from 0.003 to 0.013 µg g(-1). The CCα was ranged from 0.032 to 0.943 µg g(-1), and the CCβ from 0.053 to 1.604 µg g(-1). The obtained recovery values were from 78% to 119%. In addition, the method exhibited an appropriate robustness for all parameter evaluated. Base in our data, it was concluded that the performance parameters demonstrated total method adequacy for the detection and quantification of carbohydrates and organic acids in goat milk yogurts. The application of the method was successfully applied to monitoring different goat milk yogurts during fermentation. Copyright © 2016 Elsevier B.V. All rights reserved.
Adegoke, Oluwasesan; Kato, Tatsuya; Park, Enoch Y
2016-06-15
Conventional techniques used to diagnose influenza virus face several challenges, such as low sensitivity, slow detection, false positive results and misinterpreted data. Hence, diagnostic probes that can offer robust detection qualities, such as high sensitivity, rapid detection, elimination of false positive data, and specificity for influenza virus, are urgently needed. The near-infrared (NIR) range is an attractive spectral window due to low photon absorption by biological tissues, hence well-constructed fluorescent biosensors that emit within the NIR window can offer an improved limit of detection (LOD). Here, we demonstrate the use of a newly synthesized NIR quinternary alloyed CdZnSeTeS quantum dots (QDs) as an ultrasensitive fluorescence reporter in a conjugated molecular beacon (MB) assay to detect extremely low concentrations of influenza virus H1N1 RNA. Under optimum conditions, two different strains of influenza virus H1N1 RNA were detected based on fluorescence enhancement signal transduction. We successfully discriminated between two different strains of influenza virus H1N1 RNA based on the number of complementary nucleotide base pairs of the MB to the target RNA sequence. The merits of our bioprobe system are rapid detection, high sensitivity (detects H1N1 viral RNA down to 2 copies/mL), specificity and versatility (detects H1N1 viral RNA in human serum). For comparison, a conventional CdSe/ZnS-MB probe could not detect the extremely low concentrations of H1N1 viral RNA detected by our NIR alloyed CdZnSeTeS-MB probe. Our bioprobe detection system produced a LOD as low as ~1 copy/mL and is more sensitive than conventional molecular tests and rapid influenza detection tests (RIDTS) probes. Copyright © 2016 Elsevier B.V. All rights reserved.
Xu, Jingguo; Guo, Jia; Maina, Sarah Wanjiku; Yang, Yumeng; Hu, Yimin; Li, Xuanxuan; Qiu, Jiarong; Xin, Zhihong
2018-05-15
An ultra-sensitive aptamer-based biosensor for the detection of staphylococcus aureus was established by adopting the nicking enzyme amplification reaction (NEAR) and the rolling circle amplification (RCA) technologies. Aptamer-probe (AP), containing an aptamer and a probe sequence, was developed to act as the recognition unit of the biosensor, which was specifically bound to S. aureus. The probe was released from AP and initiated into the subsequent DNA amplification reactions where S. aureus was present, converting the detection of S. aureus to the investigation of probe oligonucleotide. The RCA amplification products contained a G-quadruplex motif and formed a three dimensional structure in presence of hemin. The G4/hemin complex showed horseradish peroxidase (HRP)-mimic activity and catalyzed the chemiluminescence reaction of luminol mediated by H 2 O 2 . The results showed that the established biosensor could detect S. aureus specifically with a good linear correlation at 5-10 4 CFU/mL. The signal values based on NEAR-RCA two-step cycle were boosted acutely, much higher than that relied on one-cycle magnification. The limit of detection (LoD) was determined to be as low as 5 CFU/mL. The established aptasensor exhibited a good discrimination of living against dead S. aureus, and can be applied to detect S. aureus in the food industry. Copyright © 2018 Elsevier Inc. All rights reserved.
Xiao, Xue; Tao, Jing; Zhang, Hong Zhi; Huang, Cheng Zhi; Zhen, Shu Jun
2016-11-15
Graphene oxide (GO) is an excellent fluorescence anisotropy (FA) amplifier. However, in the conventional GO amplified FA strategy, one target can only induce the FA change of one fluorophore on probe, which limits the detection sensitivity. Herein, we developed an exonuclease III (Exo III) aided GO amplified FA strategy by using aptamer as an recognition element and ricin B-chain as a proof-of-concept target. The aptamer was hybridized with a blocker sequence and linked onto the surface of magnetic beads (MBs). Upon the addition of ricin B-chain, blocker was released from the surface of MBs and hybridized with the dye-modified probe DNA on the surface of GO through the toehold-mediated strand exchange reaction. The formed blocker-probe DNA duplex triggered the Exo III-assisted cyclic signal amplification by repeating the hybridization and digestion of probe DNA, liberating the fluorophore with several nucleotides (low FA value). Thus, ricin B-chain could be sensitively detected by the significantly decreased FA. The linear range was from 1.0μg/mL to 13.3μg/mL and the limit of detection (LOD) was 400ng/mL. This method improved the sensitivity of FA assay and it could be generalized to any kind of target detection based on the use of an appropriate aptamer. Copyright © 2016 Elsevier B.V. All rights reserved.
A novel fluorescent probe (dtpa-bis(cytosine)) for detection of Eu(III) in rare earth metal ions
NASA Astrophysics Data System (ADS)
Yang, Fan; Ren, Peipei; Liu, Guanhong; Song, Youtao; Bu, Naishun; Wang, Jun
2018-03-01
In this paper, a novel fluorescent probe, dtpa-bis(cytosine), was designed and synthesized for detecting europium (Eu3 +) ion. Upon addition of Eu3 + ions into the dtpa-bis(cytosine) solution, the fluorescence intensity can strongly be enhanced. Conversely, adding other rare earth metal ions, such as Y3 +, Ce3 +, Pr3 +, Nd3 +, Sm3 +, Gd3 +, Tb3 +, Dy3 +, Ho3 +, Er3 +, Yb3 + and Lu3 +, into dtpa-bis(cytosine) solution, the fluorescence intensity is decreased slightly. Some parameters affecting the fluorescence intensity of dtpa-bis(cytosine) solution in the presence of Eu3 + ions were investigated, including solution pH value, Eu3 + ion concentration and interfering substances. The detection mechanism of Eu3 + ion using dtpa-bis(cytosine) as fluorescent probe was proposed. Under optimum conditions, the fluorescence emission intensities of EuIII-dtpa-bis(cytosine) at 375 nm in the concentration range of 0.50 × 10- 5 mol • L- 1-5.00 × 10- 5 mol • L- 1 of Eu3 + ion display a better linear relationship. The limit of detection (LOD) was determined as 8.65 × 10- 7 mol • L- 1 and the corresponding correlation coefficient (R2) of the linear equation is 0.9807. It is wished that the proposed method could be applied for sensitively and selectively detecting Eu3 + ion.
Wu, Hui-Fen; Ku, Hsin-Yi; Yen, Jyh-Hao
2008-07-01
A liquid-phase microextraction (LPME) method using a micropipette with disposable tips was demonstrated for coupling to atmospheric pressure MALDI-MS (AP-MALDI/MS) as a concentrating probe for rapid analysis and quantitative determination of nortriptyline drug from biological matrices including human urine and human plasma. This technique was named as micropipette extraction (MPE). The best optimized parameters of MPE coupled to AP-MALDI/MS experiments were extraction solvent, toluene; extraction time, 5 min; sample agitation rate, 480 rpm; sample pH, 7; salt concentration, 30%; hole size of micropipette tips, 0.61 mm (id); and matrix concentration, 1000 ppm using alpha-cyano-4-hydroxycinnamic acid (CHCA) as a matrix. Three detection modes of AP-MALDI/MS analysis including full scan, selective ion monitor (SIM), and selective reaction monitor (SRM) of MS/MS were also compared for the MPE performance. The results clearly demonstrated that the MS/MS method provides a wider linear range and lower LODs but poor RSDs than the full scan and SIM methods. The LOD values for the MPE under SIM and MS/MS modes in water, urine, and plasma were 6.26, 47.5, and 94.9 nM, respectively. The enrichment factors (EFs) of this current approach were 36.5-43.0 fold in water. In addition, compared to single drop microextraction (SDME) and LPME using a dual gauge microsyringe with a hollow fiber (LPME-HF) technique, the LODs acquired by the MPE method under MS/MS modes were comparable to those of LPME-HF and SDME but it is more convenient than both methods. The advantages of this novel method are simple, easy to use, low cost, and no contamination between experiments since disposable tips were used for the micropipettes. The MPE has the potential to be widely used in the future because it only requires a simple micropipette to perform all extraction processes. We believe that this technique can be a powerful tool for MALDI/MS analysis of biological samples and clinical applications.
Magneto immunofluorescence assay for diagnosis of celiac disease.
Kergaravat, Silvina V; Beltramino, Luis; Garnero, Nidia; Trotta, Liliana; Wagener, Marta; Fabiano, Silvia N; Pividori, Maria Isabel; Hernandez, Silvia R
2013-10-10
A magneto immunofluorescence assay for the detection of anti-transglutaminase antibodies (ATG2) in celiac disease was developed. The ATG2 were recognized by transglutaminase enzyme immobilized on the magnetic beads and then the immunological reaction was revealed by antibodies labeled with peroxidase. The fluorescent response of the enzymatic reaction with o-phenylenediamine and H2O2 as substrates was correlated with anti-transglutaminase titer, showing EC50 and LOD values of 1:11,600 and 1:74,500 of antibody titers, respectively. A total number of 29 sera samples from clinically confirmed cases of celiac disease and 19 negative control samples were tested by the novel magneto immunofluorescence assay. The data were submitted to the receiver-operating characteristic plot (ROC) analysis which indicated that 8.1 U was the most effective cut-off value to discriminate correctly between celiac and non-celiac patients. The immunofluorescence assay exhibited a sensitivity of 96.6%, a specificity of 89.5% and an efficiency 93.8% compared with the commercial optical ELISA kit. Copyright © 2013 Elsevier B.V. All rights reserved.
Seyam, Emaduldin; Hefzy, Enas
2018-03-01
Laparoscopic ovarian drilling (LOD) is still a controversial decision; due to the long term hazards; so short and long term predictors after the procedure should be taken in consideration. The aim of this work was to investigate the role of the serum level of tumor necrosis factor alpha (TNF-α) and other polycystic ovarian disease (PCOD) relevant clinical and biochemical factors as a predictor of spontaneous ovulation after laparoscopic ovarian drilling (LOD) in women with clomiphene citrate resistant polycystic ovarian disease (CCR-PCOD). It was a prospective research work, where 150 infertile women with CCR-PCOD had been recruited. TNF-α serum level, which is an inflammatory biomarker, was investigated in addition to other PCOD relevant clinical and biochemical parameters as possible predictors of successful spontaneous ovulation and subsequent pregnancy after LOD. Recruited women with higher preoperative levels of TNF-α, LH, and androstenedione had significantly higher rates of spontaneous ovulation within the first three months follow up after LOD, in contrast to obese women with BMI ≥ 25 kg/m2, long duration of infertility ≥3 years, marked biochemical hyperandrogenism (testosterone levels ≥4.5 nmol/L, free androgen index ≥15), and high insulin resistance (IR). Ninty five (95 = 63.3%) women in between women regularly menstruated (105 = 70%) had spontaneous ovulation, and of those spontaneously ovulated, 35(36.8%) women got pregnant spontaneously during the first 3 months follow up. Extended follow up for 12 months period revealed that 61 women got pregnant, with cumulative pregnancy rate of 58%. Logistic regression showed that the best cut-off values for spontaneous ovulation after LOD were 65.1 pg/ml, 11.5 IU/l, and 3.1 ng/ml and with a sensitivity of 91%, 88%, 55%, and with a specificity of 85%, 79%, 78%, for TNF-α, LH, androstenedione serum level respectively. TNF-α, LH, and Androstenedione could be considered as reliable predictors to depend on for recruiting the ideal women candidates with CCR-PCOD; to have the maximum benefits after LOD treatment option. Copyright © 2018 Elsevier B.V. All rights reserved.
Determination of Inorganic Ion Profiles of Illicit Drugs by Capillary Electrophoresis.
Evans, Elizabeth; Costrino, Carolina; do Lago, Claudimir L; Garcia, Carlos D; Roux, Claude; Blanes, Lucas
2016-11-01
A portable capillary electrophoresis instrument with dual capacitively coupled contactless conductivity detection (C 4 D) was used to determine the inorganic ionic profiles of three pharmaceutical samples and precursors of two illicit drugs (contemporary samples of methylone and para-methoxymethamphetamine). The LODs ranged from 0.10 μmol/L to 1.25 μmol/L for the 10 selected cations, and from 0.13 μmol/L to 1.03 μmol/L for the eight selected anions. All separations were performed in less than 6 min with migration times and peak area RSD values ranging from 2 to 7%. The results demonstrate the potential of the analysis of inorganic ionic species to aid in the identification and/or differentiation of unknown tablets, and real samples found in illicit drug manufacture scenarios. From the resulting ionic fingerprint, the unknown tablets and samples can be further classified. © 2016 American Academy of Forensic Sciences.
Shim, You-Shin; Kim, Jong-Chan; Jeong, Seung-Weon
2016-01-01
A simultaneous analytical method for piperine, capsaicin, and dihydrocapsaicin in Korean instant-noodle soup base using HPLC was validated in terms of precision, accuracy, sensitivity, and linearity. The HPLC separation was performed on a reversed-phase C18 column (5 μm particle size, 4.6 mm id, 250 mm length) using a UV detector fixed at 280 nm. The LOD and LOQ of the HPLC analyses ranged from 0.25 to 1.03 mg/kg. The intraday and interday precisions of the individual piperine, capsaicin, and dihydrocapsaicin were <10.55%, and the recovery values ranged from 85.43 to 94.68%. The calibration curves exhibited good linearity (r(2) = 0.999) within the tested ranges. These results suggest that the analytical method in this study can be used to classify Korean instant noodles based on their levels of spiciness.
Şenel, Mehmet
2015-03-01
A film of chitosan-polypyrrole-gold nanoparticles was fabricated by in-situ chemical synthesis method and its application in glucose biosensor was investigated. The obtained biosensor exhibited a high and reproducible sensitivity of 0.58μA/mM, response time ~4s, linear dynamic range from 1 to 20mM, correlation coefficient of R(2)=0.9981, and limit of detection (LOD), based on S/N ratio (S/N=3) of 0.068mM. A value of 1.83mM for the apparent Michaelis-Menten constant was obtained. The resulting bio-nanocomposite provided a suitable environment for the enzyme to retain its bioactivity at considerably extreme conditions, and the decorated gold nanoparticles in the bio-nanocomposite offer good affinity to enzyme. Copyright © 2014. Published by Elsevier B.V.
Enhancing Activity and Stability of Uricase from Lactobacillus plantarum by Zeolite immobilization
NASA Astrophysics Data System (ADS)
Iswantini, D.; Nurhidayat, N.; Sarah
2017-03-01
Lactobacillus plantarum has been known be able to produce uricase for uric acid biosensor. Durability and stability of L. plantarum in generating uricase enzyme was low. Hence, we tried to enhance its durability and stability by immobilizing it onto activated 250 mg zeolite at room temperature using 100 μL L.plantarum suspension and 2.87 mM uric acid, while Michaelis-Menten constant (KM) and Vmax were obtained at 6.7431 mM and 0.9171 µA consecutively, and the linearity range was 0.1-3.3 mM (R2 = 0.9667). Limit of detection (LOD) and limit of quantification (LOQ) value of the measurement were 0.4827 mM and 1.6092 mM respectively. Biosensor stability treatment was carried out in two different treatments, using the same electrode and using disposable electrode. The disposable electrode stability showed better result based on repeated measurements, but stability was still need improvement.
Tomassetti, Mauro; Merola, Giovanni; Martini, Elisabetta; Campanella, Luigi; Sanzò, Gabriella; Favero, Gabriele; Mazzei, Franco
2017-01-01
In this research, we developed a direct-flow surface plasmon resonance (SPR) immunosensor for ampicillin to perform direct, simple, and fast measurements of this important antibiotic. In order to better evaluate the performance, it was compared with a conventional amperometric immunosensor, working with a competitive format with the aim of finding out experimental real advantages and disadvantages of two respective methods. Results showed that certain analytical features of the new SPR immunodevice, such as the lower limit of detection (LOD) value and the width of the linear range, are poorer than those of a conventional amperometric immunosensor, which adversely affects the application to samples such as natural waters. On the other hand, the SPR immunosensor was more selective to ampicillin, and measurements were more easily and quickly attained compared to those performed with the conventional competitive immunosensor. PMID:28394296
Zhao, Yuan; Yang, Qingrui; Chang, Ye; Pang, Wei; Zhang, Hao; Duan, Xuexin
2017-01-01
This paper demonstrates a novel micro-size (120 μm × 200 μm) piezoelectric gas sensor based on a piezotransduced single-crystal silicon bulk acoustic resonator (PSBAR). The PSBARs operate at 102 MHz and possess high Q values (about 2000), ensuring the stability of the measurement. A corresponding gas sensor array is fabricated by integrating three different self-assembled monolayers (SAMs) modified PSBARs. The limit of detection (LOD) for ethanol vapor is demonstrated to be as low as 25 ppm with a sensitivity of about 1.5 Hz/ppm. Two sets of identification code bars based on the sensitivities and the adsorption energy constants are utilized to successfully discriminate isopropanol (IPA), ethanol, hexane and heptane vapors at low and high gas partial pressures, respectively. The proposed sensor array shows the potential to form a portable electronic nose system for volatile organic compound (VOC) differentiation. PMID:28672852
Zhao, Yuan; Yang, Qingrui; Chang, Ye; Pang, Wei; Zhang, Hao; Duan, Xuexin
2017-06-26
This paper demonstrates a novel micro-size (120 μm × 200 μm) piezoelectric gas sensor based on a piezotransduced single-crystal silicon bulk acoustic resonator (PSBAR). The PSBARs operate at 102 MHz and possess high Q values (about 2000), ensuring the stability of the measurement. A corresponding gas sensor array is fabricated by integrating three different self-assembled monolayers (SAMs) modified PSBARs. The limit of detection (LOD) for ethanol vapor is demonstrated to be as low as 25 ppm with a sensitivity of about 1.5 Hz/ppm. Two sets of identification code bars based on the sensitivities and the adsorption energy constants are utilized to successfully discriminate isopropanol (IPA), ethanol, hexane and heptane vapors at low and high gas partial pressures, respectively. The proposed sensor array shows the potential to form a portable electronic nose system for volatile organic compound (VOC) differentiation.
A survey of free glutamic acid in foods using a robust LC-MS/MS method.
Cebi, Nur; Dogan, Canan Ekinci; Olgun, Elmas Oktem; Sagdic, Osman
2018-05-15
An effective and simultaneous liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was used with the aim of quantifying monosodium glutamate (MSG) in foodstuffs, such as chips, taste cubes, sauces and soups. The results were linear (R 2 = 1), with very low LOD and LOQ values, 1.0 µg/kg, 5.0 µg/kg, respectively. Excellent repeatability and reproducibility were also achieved. This highly sensitive and robust LC-MS/MS technique was applied successfully for the detection and quantification of MSG in a wide variety of foodstuffs. MSG contents ranged from 0.01 g/100 g to 15.39 g/100 g in food samples. Importantly, determination of free glutamic acid in the daily diet could also prevent various side effects associated with consumption of excess free glutamic acid. Copyright © 2017 Elsevier Ltd. All rights reserved.
Andrade, Daniel F; Pereira-Filho, Edenir Rodrigues
2016-10-11
Contaminants (Cd, Cr, and Pb) as well as minor (B, Cu, Mn, Na, and Zn) and major (Ca and Mg) elements were directly determined in solid fertilizer samples using laser-induced breakdown spectroscopy (LIBS). Factorial designs were used to define the most appropriate LIBS parameters and pellet pressure on solid fertilizers. Emission lines for all of the analytes were collected and employed 12 signal normalization modes. The best results were obtained using a laser energy of 75 mJ, a spot size of 50 μm, a pressure of 10 t/in., and a delay of 2.0 μs. Good correlation was obtained between the calibration model's prediction using the proposed LIBS method and the reference values obtained with ICP-OES. The limits of detection (LOD) for the proposed method varied from 2 mg/kg (for Cd) to 1% (for Zn).
Pego, A M F; Roveri, F L; Kuninari, R Y; Leyton, V; Miziara, I D; Yonamine, M
2017-05-01
Hair testing is a recognized approach when it comes to accessing historical drug use. According to the World Drug Report of United Nations Office on Drugs and Crime (UNODC) 2015, Brazil is the largest cocaine (COC) market in South America. New analytical methodologies to detect crack/cocaine analytes in hair samples are highly desirable. Here, a method consisting of a liquid-phase microextraction (LPME) as a clean-up step, followed by gas chromatography-mass spectrometry (GC-MS) analysis has been proposed. The new validated method consisted of a washing step; an overnight incubation with methanol and a quick derivatization with butylchloroformate. Once derivatized, the samples were then submitted to the LPME procedure. Limits of detection (LoD) and quantitation (LoQ) obtained were of 0.1 and 0.5ng/mg for COC 0.4 and 0.5ng/mg for anhydroecgonine methyl ester (AEME); 0.03 and 0.05 for cocaethylene (CE), respectively and 0.05ng/mg for both LoD and LoQ for benzoylecgonine (BZE). All calibration curves were linear over the scope applied, from LoQ up to 20ng/mg, with a r 2 >0.99. Precision and accuracy assays showed acceptable %RSD values, according to international guidelines. Twelve postmortem head hair samples stemming from the Institute of Legal Medicine of Sao Paulo (IML-SP) have been analyzed, from which seven have shown to be positive for COC (0.75->20ng/mg) and BZE (0.1->20ng/mg). Apart from COC's main metabolite, four samples were also positive for CE (0.1-3.9ng/mg) and three samples for AEME (0.5-4.9ng/mg). To conclude, the LPME technique together with GC-MS analysis have shown promising results and were able to meet the demand of the laboratory of analyzing postmortem hair samples to look for all four analytes. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
López-Muñoz, Gerardo A; Estevez, M-Carmen; Peláez-Gutierrez, E Cristina; Homs-Corbera, Antoni; García-Hernandez, M Carmen; Imbaud, J Ignacio; Lechuga, Laura M
2017-10-15
Nanostructure-based plasmonic biosensors have quickly positioned themselves as interesting candidates for the design of portable optical biosensor platforms considering the potential benefits they can offer in integration, miniaturization, multiplexing, and real-time label-free detection. We have developed a simple integrated nanoplasmonic sensor taking advantage of the periodic nanostructured array of commercial Blu-ray discs. Sensors with two gold film thicknesses (50 and 100nm) were fabricated and optically characterized by varying the oblique-angle of the incident light in optical reflectance measurements. Contrary to the use normal light incidence previously reported with other optical discs, we observed an enhancement in sensitivity and a narrowing of the resonant linewidths as the light incidence angle was increased, which could be related to the generation of Fano resonant modes. The new sensors achieve a figure of merit (FOM) up to 35 RIU -1 and a competitive bulk limit of detection (LOD) of 6.3×10 -6 RIU. These values significantly improve previously reported results obtained with normal light incidence reflectance measurements using similar structures. The sensor has been combined with versatile, simple, ease to-fabricate microfluidics. The integrated chip is only 1cm 2 (including a PDMS flow cell with a 50µm height microfluidic channel fabricated with double-sided adhesive tape) and all the optical components are mounted on a 10cm×10cm portable prototype, illustrating its facile miniaturization, integration and potential portability. Finally, to assess the label-free biosensing capability of the new sensor, we have evaluated the presence of specific antibodies against the GTF2b protein, a tumor-associate antigen (TAA) related to colorectal cancer. We have achieved a LOD in the pM order and have assessed the feasibility of directly measuring biological samples such as human serum. Copyright © 2017 Elsevier B.V. All rights reserved.
Ślachciński, Mariusz
2016-12-01
The Flow Focusing Pneumatic Nebulizer (FFPN) working at low liquid flow rates was evaluated for the elemental analysis in slurried samples by argon-helium microwave induced plasma optical emission spectrometry (MIP-OES). The obtained results achieved were compared with commercially available V-groove Babington type nebulizer (VBPN). A univariate approach and the simplex optimization procedure were used to achieve optimized conditions and derive analytical figures of merit. Analytical performance of the micro nebulization system was characterized by a determination of the limits of detection (LODs), the precision (RSDs) and the wash-out times for Ba, Ca, Cd, Cu, Fe, Mg, Mn, Pb and Sr. The experimental concentration detection limits for simultaneous determination, calculated as the concentration giving a signal equal to three times of the standard deviation of the blank (LOD, 3σ blank criterion, peak height) were 0.9, 0.2, 0.3, 0.2, 0.3, 0.1, 0.2, 0.4, 0.4 and 0.3ngmL -1 for Ba, Ca, Cd, Cu, Fe, Mg, Mn, Pb and Sr, respectively. The method offers relatively good precision (RSD ranged from 5% to 8%) for micro-slurry sampling analysis. Analyses of the certified reference materials (NRCC DOLT-2, GBW 07302 and SRM 2710) were performed in order to determine the accuracy available with the presented nebulization systems. The measured contents of elements in the reference materials were in satisfactory agreement with the certified values. In addition, these elements were determined in two real samples. Slurry concentration up to 3% m/v (particles <20μm), prepared in 10% m/v HCl through the application of ultrasonic agitation, was used with calibration by the standard addition technique. An ultrasonic probe was used to homogenize the slurry in the polypropylene bottle just before its introduction into the nebulizer. The nebulizers exhibited no clogging problems. Copyright © 2016 Elsevier B.V. All rights reserved.
Ravindranath, Rini; Periasamy, Arun Prakash; Roy, Prathik; Chen, Yu-Wen; Chang, Huan-Tsung
2018-06-04
We have devised a unique strategy for highly sensitive, selective, and colorimetric detection of mercury based on analyte-induced enhancement of the photocatalytic activity of TiO 2 -Au nanospheres (TiO 2 -Au NSs) toward degradation of methylene blue (MB). Through electrostatic interactions, Au nanoparticles are attached to poly-(sodium 4-styreneulfonate)/poly(diallyldimethylammonium chloride) modified TiO 2 nanoparticles, which then form an Au shell on each TiO 2 core through reduction of Au 3+ with ascorbic acid. Notably, the deposition of Hg species (Hg 2+ /CH 3 Hg + ) onto TiO 2 -Au NSs through strong Au-Hg aurophilic interactions speeds up catalytic degradation of MB. The first-order degradation rates of MB by TiO 2 -Au NSs and TiO 2 -Au-Hg NSs are 1.4 × 10 -2 min -1 and 2.1 × 10 -2 min -1 , respectively. Using a commercial absorption spectrometer, the TiO 2 -Au NSs/MB approach provides linearity (R 2 = 0.98) for Hg 2+ over a concentration range of 10.0 to 100.0 nM, with a limit of detection (LOD) of 1.5 nM. On the other hand, using a low-cost smartphone app that records the color changes (ΔRGB) of MB solution based on the red-blue-green (RGB) component values, the TiO 2 -Au NSs/MB approach provides an LOD of 2.0 nM for Hg 2+ and 5.0 nM for CH 3 Hg + , respectively. Furthermore, the smartphone app sensing system has been validated for the analyses of various samples, including tap water, lake water, soil, and Dorm II, showing its great potential for on-line analysis of environmental and biological samples. Graphical Abstract ᅟ.
Niu, Chenqi; Xu, Yuancong; Zhang, Chao; Zhu, Pengyu; Huang, Kunlun; Luo, Yunbo; Xu, Wentao
2018-05-01
As genetically modified (GM) technology develops and genetically modified organisms (GMOs) become more available, GMOs face increasing regulations and pressure to adhere to strict labeling guidelines. A singleplex detection method cannot perform the high-throughput analysis necessary for optimal GMO detection. Combining the advantages of multiplex detection and droplet digital polymerase chain reaction (ddPCR), a single universal primer-multiplex-ddPCR (SUP-M-ddPCR) strategy was proposed for accurate broad-spectrum screening and quantification. The SUP increases efficiency of the primers in PCR and plays an important role in establishing a high-throughput, multiplex detection method. Emerging ddPCR technology has been used for accurate quantification of nucleic acid molecules without a standard curve. Using maize as a reference point, four heterologous sequences ( 35S, NOS, NPTII, and PAT) were selected to evaluate the feasibility and applicability of this strategy. Surprisingly, these four genes cover more than 93% of the transgenic maize lines and serve as preliminary screening sequences. All screening probes were labeled with FAM fluorescence, which allows the signals from the samples with GMO content and those without to be easily differentiated. This fiveplex screening method is a new development in GMO screening. Utilizing an optimal amplification assay, the specificity, limit of detection (LOD), and limit of quantitation (LOQ) were validated. The LOD and LOQ of this GMO screening method were 0.1% and 0.01%, respectively, with a relative standard deviation (RSD) < 25%. This method could serve as an important tool for the detection of GM maize from different processed, commercially available products. Further, this screening method could be applied to other fields that require reliable and sensitive detection of DNA targets.
2013-01-01
Background BRAF mutation is an important diagnostic and prognostic marker in patients with papillary thyroid carcinoma (PTC). To be applicable in clinical laboratories with limited equipment, diverse testing methods are required to detect BRAF mutation. Methods A shifted termination assay (STA) fragment analysis was used to detect common V600 BRAF mutations in 159 PTCs with DNAs extracted from formalin-fixed paraffin-embedded tumor tissue. The results of STA fragment analysis were compared to those of direct sequencing. Serial dilutions of BRAF mutant cell line (SNU-790) were used to calculate limit of detection (LOD). Results BRAF mutations were detected in 119 (74.8%) PTCs by STA fragment analysis. In direct sequencing, BRAF mutations were observed in 118 (74.2%) cases. The results of STA fragment analysis had high correlation with those of direct sequencing (p < 0.00001, κ = 0.98). The LOD of STA fragment analysis and direct sequencing was 6% and 12.5%, respectively. In PTCs with pT3/T4 stages, BRAF mutation was observed in 83.8% of cases. In pT1/T2 carcinomas, BRAF mutation was detected in 65.9% and this difference was statistically significant (p = 0.007). Moreover, BRAF mutation was more frequent in PTCs with extrathyroidal invasion than tumors without extrathyroidal invasion (84.7% versus 62.2%, p = 0.001). To prepare and run the reactions, direct sequencing required 450 minutes while STA fragment analysis needed 290 minutes. Conclusions STA fragment analysis is a simple and sensitive method to detect BRAF V600 mutations in formalin-fixed paraffin-embedded clinical samples. Virtual Slides The virtual slide(s) for this article can be found here: http://www.diagnosticpathology.diagnomx.eu/vs/5684057089135749 PMID:23883275
Li, Chenglong; Mi, Tiejun; Conti, Gea Oliveri; Yu, Qing; Wen, Kai; Shen, Jianzhong; Ferrante, Margherita; Wang, Zhanhui
2015-05-27
This paper reports the development of a screening fluorescence polarization immunoassay (FPIA) for the simultaneous detection of fumonisins B1 (FB1) and B2 (FB2) in maize. Three FB1 tracers including FB1-fluorescein isothiocyanate isomer I (FB1-FITC), FB1-5-([4,6-dichlorotriazine-2-yl]amino)-fluorescein (FB1-5-DTAF), and FB1-Texas Red-X succinimidyl ester (FB1-TRX) were synthesized and studied to select appropriate tracer-antibody pairs using seven previously produced monoclonal antibodies (mAbs). An FPIA employing the pair of FB1-FITC and mAb 4B9 showing 98.9% cross-reactivity (CR) toward FB2 was used to simultaneously detect FB1 and FB2. Maize flour samples were extracted with methanol/water (2:3, v/v). After optimization, the FPIA revealed a limit of detection (LOD) of 157.4 μg/kg for FB1 and an LOD of 290.6 μg/kg for FB2, respectively. Recoveries were measured for spiked samples of FB1 or FB2 separately, ranging from 84.7 to 93.6%, with a coefficient of variation (CV) of <9.9%. Total time needed for FPIA including sample pretreatment was <30 min. The FPIA was used to screen naturally contaminated maize samples. Results detected by FPIA showed good agreement with that of HPLC-MS/MS with a fit of R(2) = 0.99 for the simultaneous detection of FB1 and FB2. The established method offered a rapid, simple, sensitive, and high-throughput screening tool for the detection of fumonisins in maize.
Chilton, C H; Crowther, G S; Freeman, J; Todhunter, S L; Nicholson, S; Longshaw, C M; Wilcox, M H
2014-02-01
Fidaxomicin reduces the risk of recurrent Clostridium difficile infection (CDI) compared with vancomycin. We investigated fidaxomicin primary or secondary treatment efficacy using a gut model. Four triple-stage chemostat gut models were inoculated with faeces. After clindamycin induction of CDI, fidaxomicin (200 mg/L twice daily), vancomycin (125 mg/L four times daily) or metronidazole (9.3 mg/L three times daily) was administered for 7 days. Following failure/CDI recurrence, fidaxomicin (200 mg/L twice daily, 7 days) was instilled. C. difficile (CD) total viable counts (TVC), spore counts (SP), toxin titres (CYT), gut bacteria counts and antimicrobial concentrations were measured throughout. Fidaxomicin instillation reduced CD TVC/SP and CYT below the limit of detection (LOD) after 2 and 4 days, respectively, with no CDI recurrence. Metronidazole instillation failed to decrease CD TVC or CYT. Vancomycin instillation reduced CD TVC and CYT to LOD by day 4, but SP persisted. Recurrence occurred 13 days after vancomycin instillation; subsequent fidaxomicin instillation reduced CD TVC/SP/CYT below the LOD from day 2. CD was isolated sporadically, with no evidence of spore recrudescence or toxin production. Fidaxomicin had a minimal effect on the microflora, except for bifidobacteria. Fidaxomicin was detected for at least 21 days post-instillation, whereas other antimicrobials were undetectable beyond ∼4 days. Fidaxomicin successfully treated simulated primary and recurrent CDI. Fidaxomicin was superior to metronidazole in reducing CD TVC and SP, and superior to vancomycin in reducing SP without recurrence of vegetative cell growth. Fidaxomicin, but not vancomycin or metronidazole, persisted in the gut model for >20 days after instillation.
Chu, Shaogang; Letcher, Robert J
2009-06-01
Perfluorooctane sulfonate (PFOS) is found globally as an environmental contaminant and is highly bioaccumulative in exposed biota including humans. However, there is a dearth of environmental information on the isomeric profile of PFOS, especially in biological samples, which requires suitable analysis methods for the identification and quantification of ultratrace amounts. In the present study, a novel method was developed that incorporates clean up by solid-phase extraction (SPE) WAX cartridges and in-port derivatization-gas chromatography-mass spectrometry (GC/MS) to identify and quantitatively determine linear PFOS (L-PFOS) and branched (monotrifluoromethyl and bistrifluoromethyl) isomers in PFOS technical product and in environmentally relevant biological samples. Tetrabutylammonium hydroxide (TBAH) was used for derivatization via an in situ pyrolytic alkylation reaction that occurred in the GC injector and generated butyl PFOS isomer derivatives. In addition to L-PFOS, ten branched PFOS isomers were identified in the technical product. The environmental relevance of branched PFOS isomers in addition to L-PFOS was evidenced by the presence of six branched and L-PFOS in representative herring gull and double-crested cormorant egg, and polar bear liver and plasma samples from the Great Lakes and Arctic, respectively. For all PFOS isomers in the technical product and biota samples the method demonstrated high sensitivity with the limit of detection (LOD) ranging from 0.05 to 0.25 ng/mL, with exception of L-PFOS where the LOD was 1.46 ng/mL. For the biotic samples, the method detection limits (MDLs) were slightly higher than the LODs and ranged from 0.09 to 0.46 ng/g wet weight (w.w.) with exception of L-PFOS (MDL = 6.87 ng/g w.w.).