Sample records for detection system reporting

  1. Simple colonoscopy reporting system checking the detection rate of colon polyps.

    PubMed

    Kim, Jae Hyun; Choi, Youn Jung; Kwon, Hye Jung; Park, Seun Ja; Park, Moo In; Moon, Won; Kim, Sung Eun

    2015-08-21

    To present a simple colonoscopy reporting system that can be checked easily the detection rate of colon polyps. A simple colonoscopy reporting system Kosin Gastroenterology (KG quality reporting system) was developed. The polyp detection rate (PDR), adenoma detection rate (ADR), serrated polyp detection rate (SDR), and advanced adenoma detection rate (AADR) are easily calculated to use this system. In our gastroenterology center, the PDR, ADR, SDR, and AADR test results from each gastroenterologist were updated, every month. Between June 2014, when the program was started, and December 2014, the overall PDR and ADR in our center were 62.5% and 41.4%, respectively. And the overall SDR and AADR were 7.5% and 12.1%, respectively. We envision that KG quality reporting system can be applied to develop a comprehensive system to check colon polyp detection rates in other gastroenterology centers.

  2. Lexington incident detection system evaluation report : final report.

    DOT National Transportation Integrated Search

    2005-11-01

    This report describes the evaluation of an experimental incident detection system implemented within the Lexington/Fayette County area by the Lexington Fayette Urban County Government Department of Traffic Engineering. The incident detection system i...

  3. Subgenomic Reporter RNA System for Detection of Alphavirus Infection in Mosquitoes

    PubMed Central

    Steel, J. Jordan; Franz, Alexander W. E.; Sanchez-Vargas, Irma; Olson, Ken E.; Geiss, Brian J.

    2013-01-01

    Current methods for detecting real-time alphavirus (Family Togaviridae) infection in mosquitoes require the use of recombinant viruses engineered to express a visibly detectable reporter protein. These altered viruses expressing fluorescent proteins, usually from a duplicated viral subgenomic reporter, are effective at marking infection but tend to be attenuated due to the modification of the genome. Additionally, field strains of viruses cannot be visualized using this approach unless infectious clones can be developed to insert a reporter protein. To circumvent these issues, we have developed an insect cell-based system for detecting wild-type sindbis virus infection that uses a virus inducible promoter to express a fluorescent reporter gene only upon active virus infection. We have developed an insect expression system that produces sindbis virus minigenomes containing a subgenomic promoter sequence, which produces a translatable RNA species only when infectious virus is present and providing viral replication proteins. This subgenomic reporter RNA system is able to detect wild-type Sindbis infection in cultured mosquito cells. The detection system is relatively species specific and only detects closely related viruses, but can detect low levels of alphavirus specific replication early during infection. A chikungunya virus detection system was also developed that specifically detects chikungunya virus infection. Transgenic Aedes aegypti mosquito families were established that constitutively express the sindbis virus reporter RNA and were found to only express fluorescent proteins during virus infection. This virus inducible reporter system demonstrates a novel approach for detecting non-recombinant virus infection in mosquito cell culture and in live transgenic mosquitoes. PMID:24367703

  4. Application of Probability of Crack Detection to Aircraft Systems Reliability.

    DOT National Transportation Integrated Search

    1993-08-31

    This report describes three tasks related to probability of crack detection (POD) and aircraft systems reliablity. All three consider previous work in which crack growth simulations and crack detection data in the Service Difficulty Report (SDR) data...

  5. Clustering and Recurring Anomaly Identification: Recurring Anomaly Detection System (ReADS)

    NASA Technical Reports Server (NTRS)

    McIntosh, Dawn

    2006-01-01

    This viewgraph presentation reviews the Recurring Anomaly Detection System (ReADS). The Recurring Anomaly Detection System is a tool to analyze text reports, such as aviation reports and maintenance records: (1) Text clustering algorithms group large quantities of reports and documents; Reduces human error and fatigue (2) Identifies interconnected reports; Automates the discovery of possible recurring anomalies; (3) Provides a visualization of the clusters and recurring anomalies We have illustrated our techniques on data from Shuttle and ISS discrepancy reports, as well as ASRS data. ReADS has been integrated with a secure online search

  6. Warning systems evaluation for overhead clearance detection : final report.

    DOT National Transportation Integrated Search

    2017-02-01

    This study reports on off-the-shelf systems designed to detect the heights of vehicles to minimize or eliminate collisions with roadway bridges. Implemented systems were identified, reviewed, and compared and relatively inexpensive options recommende...

  7. A web-based quantitative signal detection system on adverse drug reaction in China.

    PubMed

    Li, Chanjuan; Xia, Jielai; Deng, Jianxiong; Chen, Wenge; Wang, Suzhen; Jiang, Jing; Chen, Guanquan

    2009-07-01

    To establish a web-based quantitative signal detection system for adverse drug reactions (ADRs) based on spontaneous reporting to the Guangdong province drug-monitoring database in China. Using Microsoft Visual Basic and Active Server Pages programming languages and SQL Server 2000, a web-based system with three software modules was programmed to perform data preparation and association detection, and to generate reports. Information component (IC), the internationally recognized measure of disproportionality for quantitative signal detection, was integrated into the system, and its capacity for signal detection was tested with ADR reports collected from 1 January 2002 to 30 June 2007 in Guangdong. A total of 2,496 associations including known signals were mined from the test database. Signals (e.g., cefradine-induced hematuria) were found early by using the IC analysis. In addition, 291 drug-ADR associations were alerted for the first time in the second quarter of 2007. The system can be used for the detection of significant associations from the Guangdong drug-monitoring database and could be an extremely useful adjunct to the expert assessment of very large numbers of spontaneously reported ADRs for the first time in China.

  8. Framework for evaluating public health surveillance systems for early detection of outbreaks: recommendations from the CDC Working Group.

    PubMed

    Buehler, James W; Hopkins, Richard S; Overhage, J Marc; Sosin, Daniel M; Tong, Van

    2004-05-07

    The threat of terrorism and high-profile disease outbreaks has drawn attention to public health surveillance systems for early detection of outbreaks. State and local health departments are enhancing existing surveillance systems and developing new systems to better detect outbreaks through public health surveillance. However, information is limited about the usefulness of surveillance systems for outbreak detection or the best ways to support this function. This report supplements previous guidelines for evaluating public health surveillance systems. Use of this framework is intended to improve decision-making regarding the implementation of surveillance for outbreak detection. Use of a standardized evaluation methodology, including description of system design and operation, also will enhance the exchange of information regarding methods to improve early detection of outbreaks. The framework directs particular attention to the measurement of timeliness and validity for outbreak detection. The evaluation framework is designed to support assessment and description of all surveillance approaches to early detection, whether through traditional disease reporting, specialized analytic routines for aberration detection, or surveillance using early indicators of disease outbreaks, such as syndromic surveillance.

  9. Utility of the Paris System in Reporting Urine Cytology.

    PubMed

    Malviya, Kiran; Fernandes, Gwendolyn; Naik, Leena; Kothari, Kanchan; Agnihotri, Mona

    2017-01-01

    To find out the utility of The Paris System (TPS) in reporting urine cytology and to compare it with the reporting system currently used in our laboratory. This retrospective study was undertaken over a period of 1 year during which slides of all the urine specimens sent for cytological examination were retrieved from our laboratory filling system. They were blindly reviewed and reclassified according to TPS. Surgical follow-up was obtained from the uropathology services of our department. A total of 176 cases were meticulously reviewed. The mean age of the patients was 52 years, and 71% of cases presented with hematuria. Histopathological follow-up was available in 34 cases. Reporting by TPS detected 13.0% high-grade urothelial carcinoma (HGUC) and 5.1% atypical urothelial cells versus 7.3 and 11.9% by the current reporting system, respectively. The sensitivity and diagnostic accuracy for detecting HGUC of TPS were higher than those of our reporting system. TPS has increased the rate of detection of HGUC and reduced the rate of reporting "atypical" urothelial cells. TPS has also standardized the diagnostic criteria, thereby bringing uniformity and reproducibility into the system of reporting for urine cytology. © 2017 S. Karger AG, Basel.

  10. 40 CFR 63.11553 - What are my notification, reporting, and recordkeeping requirements?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... operator that installs bag leak detection systems: “This facility has installed a bag leak detection system in accordance with § 63.11552(b)(3) or (c), has prepared a bag leak detection system monitoring plan in accordance with § 63.11552(c), and will operate each bag leak detection system according to the...

  11. An Advanced Platform for Biomolecular Detection and Analysis Systems

    DTIC Science & Technology

    2005-02-01

    AFRL-IF-RS-TR-2005-54 Final Technical Report February 2005 AN ADVANCED PLATFORM FOR BIOMOLECULAR DETECTION AND ANALYSIS SYSTEMS...SUBTITLE AN ADVANCED PLATFORM FOR BIOMOLECULAR DETECTION AND ANALYSIS SYSTEMS 6. AUTHOR(S) David J. Beebe 5. FUNDING NUMBERS G...detection, analysis and response as well as many non BC warfare applications such as environmental toxicology, clinical detection and diagnosis

  12. Evaluation of Video Detection Systems and Development of Application Guidelines at Signalized Intersections

    DOT National Transportation Integrated Search

    2010-07-01

    This report documents the results of a study on evaluating three major video imaging vehicle detection systems (VIVDS) currently deployed in Nevadas urban areas. The report first provides a brief review of the features and functions of some major ...

  13. A dual-mode generalized likelihood ratio approach to self-reorganizing digital flight control system design

    NASA Technical Reports Server (NTRS)

    Bueno, R.; Chow, E.; Gershwin, S. B.; Willsky, A. S.

    1975-01-01

    The research is reported on the problems of failure detection and reliable system design for digital aircraft control systems. Failure modes, cross detection probability, wrong time detection, application of performance tools, and the GLR computer package are discussed.

  14. A low cost instrumentation system to analyze different types of milk adulteration.

    PubMed

    Das, Siuli; Sivaramakrishna, Mulinti; Biswas, Karabi; Goswami, Bhaswati

    2015-05-01

    In this paper, the design of a complete instrumentation system to detect different types of milk adulteration has been reported. A simple to use indicator type readout device is reported which can be used by milk community people. A low cost microcontroller based automatic sensing system is also reported to detect 'synthetic milk', which has been reconstructed after adulterating the milk with 'liquid-whey'. Copyright © 2014 ISA. Published by Elsevier Ltd. All rights reserved.

  15. Reducing impaired-driving recidivism using advanced vehicle-based alcohol detection systems : a report to Congress

    DOT National Transportation Integrated Search

    2007-12-01

    Vehicle-based alcohol detection systems use technologies designed to detect the presence of alcohol in a driver. Technology suitable for use in all vehicles that will detect an impaired driver faces many challenges including public acceptability, pas...

  16. 40 CFR 270.17 - Specific part B information requirements for surface impoundments.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... double liner and leak (leachate) detection, collection, and removal system, if the surface impoundment... double liners and a leak detection, collection, and removal system or alternative design is sought as... detection system is located in a saturated zone, submit detailed plans and an engineering report explaining...

  17. Evaluation of a video image detection system : final report.

    DOT National Transportation Integrated Search

    1994-05-01

    A video image detection system (VIDS) is an advanced wide-area traffic monitoring system : that processes input from a video camera. The Autoscope VIDS coupled with an information : management system was selected as the monitoring device because test...

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCann, D.; White, D.

    This paper reports on a smart alarm system installed on a number of offshore rigs and one land rig which can detect kicks more quickly than conventional systems. This rapid kick detection improves rig safety because the smaller the detected influx, the easier it is to control the well. The extensive computerized monitoring system helps drilling personnel detect fluid influxes and fluid losses before the changes in flow would normally be apparent.

  19. 40 CFR 63.10899 - What are my recordkeeping and reporting requirements?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... of each inspection, and the results of any maintenance performed on the bag filters. (ii) The date... applicable, you must keep records for bag leak detection systems as follows: (i) Records of the bag leak detection system output; (ii) Records of bag leak detection system adjustments, including the date and time...

  20. The Corralitos Observatory program for the detection of lunar transient phenomena

    NASA Technical Reports Server (NTRS)

    Hynek, J. A.; Dunlap, J. R.; Hendry, E. M.

    1976-01-01

    This is a final report on the establishment, observing procedures, and observational results of a survey program for the detection of lunar transient phenomena (LTP's) by electro-optical image conversion means. For survey, a unique detection system with an image orthicon was used as the primary element in conjunction with a 24-in. f/20 Cassegrainian telescope. Observations in three spectral ranges, with 6,466 man-hours of observing, were actually performed during the period from October 27, 1965, to April 26, 1972. Within this entire period, no color or feature change within the detection capabilities of the instrumentation was observed, either independently or in follow up of amateur LTP reports, with the exception of one general bluing and several localized bluings (probably ascribable to the effects of the terrestrial atmosphere) that were observed solely by the Corralitos system. A table is presented indicating amateur and professional reports of LTP's and the results of efforts to confirm these reports through the Corralitos system.

  1. Real-time monitoring of school absenteeism to enhance disease surveillance: a pilot study of a mobile electronic reporting system.

    PubMed

    Lawpoolsri, Saranath; Khamsiriwatchara, Amnat; Liulark, Wongwat; Taweeseneepitch, Komchaluch; Sangvichean, Aumnuyphan; Thongprarong, Wiraporn; Kaewkungwal, Jaranit; Singhasivanon, Pratap

    2014-05-12

    School absenteeism is a common source of data used in syndromic surveillance, which can eventually be used for early outbreak detection. However, the absenteeism reporting system in most schools, especially in developing countries, relies on a paper-based method that limits its use for disease surveillance or outbreak detection. The objective of this study was to develop an electronic real-time reporting system on school absenteeism for syndromic surveillance. An electronic (Web-based) school absenteeism reporting system was developed to embed it within the normal routine process of absenteeism reporting. This electronic system allowed teachers to update students' attendance status via mobile tablets. The data from all classes and schools were then automatically sent to a centralized database for further analysis and presentation, and for monitoring temporal and spatial patterns of absent students. In addition, the system also had a disease investigation module, which provided a link between absenteeism data from schools and local health centers, to investigate causes of fever among sick students. The electronic school absenteeism reporting system was implemented in 7 primary schools in Bangkok, Thailand, with total participation of approximately 5000 students. During May-October 2012 (first semester), the percentage of absentees varied between 1% and 10%. The peak of school absenteeism (sick leave) was observed between July and September 2012, which coincided with the peak of dengue cases in children aged 6-12 years being reported to the disease surveillance system. The timeliness of a reporting system is a critical function in any surveillance system. Web-based application and mobile technology can potentially enhance the use of school absenteeism data for syndromic surveillance and outbreak detection. This study presents the factors that determine the implementation success of this reporting system.

  2. The reliability and effectiveness of an electromagnetic animal detection and driver warning system.

    DOT National Transportation Integrated Search

    2012-03-01

    "This report contains data on the reliability and effectiveness of an animal detection system project along US Hwy 160 : between Durango and Bayfield, Colorado. The system that was first installed was a Perimitrax system from Senstar : Corporation....

  3. Conceptual design of a connected vehicle wrong-way driving detection and management system.

    DOT National Transportation Integrated Search

    2016-04-01

    This report describes the tasks completed to develop a concept of operations, functional requirements, and : high-level system design for a Connected Vehicle (CV) Wrong-Way Driving (WWD) Detection and Management : System. This system was designed to ...

  4. Building Intrusion Detection with a Wireless Sensor Network

    NASA Astrophysics Data System (ADS)

    Wälchli, Markus; Braun, Torsten

    This paper addresses the detection and reporting of abnormal building access with a wireless sensor network. A common office room, offering space for two working persons, has been monitored with ten sensor nodes and a base station. The task of the system is to report suspicious office occupation such as office searching by thieves. On the other hand, normal office occupation should not throw alarms. In order to save energy for communication, the system provides all nodes with some adaptive short-term memory. Thus, a set of sensor activation patterns can be temporarily learned. The local memory is implemented as an Adaptive Resonance Theory (ART) neural network. Unknown event patterns detected on sensor node level are reported to the base station, where the system-wide anomaly detection is performed. The anomaly detector is lightweight and completely self-learning. The system can be run autonomously or it could be used as a triggering system to turn on an additional high-resolution system on demand. Our building monitoring system has proven to work reliably in different evaluated scenarios. Communication costs of up to 90% could be saved compared to a threshold-based approach without local memory.

  5. Point source detection in infrared astronomical surveys

    NASA Technical Reports Server (NTRS)

    Pelzmann, R. F., Jr.

    1977-01-01

    Data processing techniques useful for infrared astronomy data analysis systems are reported. This investigation is restricted to consideration of data from space-based telescope systems operating as survey instruments. In this report the theoretical background for specific point-source detection schemes is completed, and the development of specific algorithms and software for the broad range of requirements is begun.

  6. Research on IPv6 intrusion detection system Snort-based

    NASA Astrophysics Data System (ADS)

    Shen, Zihao; Wang, Hui

    2010-07-01

    This paper introduces the common intrusion detection technologies, discusses the work flow of Snort intrusion detection system, and analyzes IPv6 data packet encapsulation and protocol decoding technology. We propose the expanding Snort architecture to support IPv6 intrusion detection in accordance with CIDF standard combined with protocol analysis technology and pattern matching technology, and present its composition. The research indicates that the expanding Snort system can effectively detect various intrusion attacks; it is high in detection efficiency and detection accuracy and reduces false alarm and omission report, which effectively solves the problem of IPv6 intrusion detection.

  7. Fluorescence detection system for microfluidic droplets

    NASA Astrophysics Data System (ADS)

    Chen, Binyu; Han, Xiaoming; Su, Zhen; Liu, Quanjun

    2018-05-01

    In microfluidic detection technology, because of the universality of optical methods in laboratory, optical detection is an attractive solution for microfluidic chip laboratory equipment. In addition, the equipment with high stability and low cost can be realized by integrating appropriate optical detection technology on the chip. This paper reports a detection system for microfluidic droplets. Photomultiplier tubes (PMT) is used as a detection device to improve the sensitivity of detection. This system improves the signal to noise ratio by software filtering and spatial filter. The fluorescence intensity is proportional to the concentration of the fluorescence and intensity of the laser. The fluorescence micro droplets of different concentrations can be distinguished by this system.

  8. Detecting cancers through tumor-activatable minicircles that lead to a detectable blood biomarker.

    PubMed

    Ronald, John A; Chuang, Hui-Yen; Dragulescu-Andrasi, Anca; Hori, Sharon S; Gambhir, Sanjiv S

    2015-03-10

    Earlier detection of cancers can dramatically improve the efficacy of available treatment strategies. However, despite decades of effort on blood-based biomarker cancer detection, many promising endogenous biomarkers have failed clinically because of intractable problems such as highly variable background expression from nonmalignant tissues and tumor heterogeneity. In this work we present a tumor-detection strategy based on systemic administration of tumor-activatable minicircles that use the pan-tumor-specific Survivin promoter to drive expression of a secretable reporter that is detectable in the blood nearly exclusively in tumor-bearing subjects. After systemic administration we demonstrate a robust ability to differentiate mice bearing human melanoma metastases from tumor-free subjects for up to 2 wk simply by measuring blood reporter levels. Cumulative change in reporter levels also identified tumor-bearing subjects, and a receiver operator-characteristic curve analysis highlighted this test's performance with an area of 0.918 ± 0.084. Lung tumor burden additionally correlated (r(2) = 0.714; P < 0.05) with cumulative reporter levels, indicating that determination of disease extent was possible. Continued development of our system could improve tumor detectability dramatically because of the temporally controlled, high reporter expression in tumors and nearly zero background from healthy tissues. Our strategy's highly modular nature also allows it to be iteratively optimized over time to improve the test's sensitivity and specificity. We envision this system could be used first in patients at high risk for tumor recurrence, followed by screening high-risk populations before tumor diagnosis, and, if proven safe and effective, eventually may have potential as a powerful cancer-screening tool for the general population.

  9. Adaptable radiation monitoring system and method

    DOEpatents

    Archer, Daniel E [Livermore, CA; Beauchamp, Brock R [San Ramon, CA; Mauger, G Joseph [Livermore, CA; Nelson, Karl E [Livermore, CA; Mercer, Michael B [Manteca, CA; Pletcher, David C [Sacramento, CA; Riot, Vincent J [Berkeley, CA; Schek, James L [Tracy, CA; Knapp, David A [Livermore, CA

    2006-06-20

    A portable radioactive-material detection system capable of detecting radioactive sources moving at high speeds. The system has at least one radiation detector capable of detecting gamma-radiation and coupled to an MCA capable of collecting spectral data in very small time bins of less than about 150 msec. A computer processor is connected to the MCA for determining from the spectral data if a triggering event has occurred. Spectral data is stored on a data storage device, and a power source supplies power to the detection system. Various configurations of the detection system may be adaptably arranged for various radiation detection scenarios. In a preferred embodiment, the computer processor operates as a server which receives spectral data from other networked detection systems, and communicates the collected data to a central data reporting system.

  10. Extended Testability Analysis Tool

    NASA Technical Reports Server (NTRS)

    Melcher, Kevin; Maul, William A.; Fulton, Christopher

    2012-01-01

    The Extended Testability Analysis (ETA) Tool is a software application that supports fault management (FM) by performing testability analyses on the fault propagation model of a given system. Fault management includes the prevention of faults through robust design margins and quality assurance methods, or the mitigation of system failures. Fault management requires an understanding of the system design and operation, potential failure mechanisms within the system, and the propagation of those potential failures through the system. The purpose of the ETA Tool software is to process the testability analysis results from a commercial software program called TEAMS Designer in order to provide a detailed set of diagnostic assessment reports. The ETA Tool is a command-line process with several user-selectable report output options. The ETA Tool also extends the COTS testability analysis and enables variation studies with sensor sensitivity impacts on system diagnostics and component isolation using a single testability output. The ETA Tool can also provide extended analyses from a single set of testability output files. The following analysis reports are available to the user: (1) the Detectability Report provides a breakdown of how each tested failure mode was detected, (2) the Test Utilization Report identifies all the failure modes that each test detects, (3) the Failure Mode Isolation Report demonstrates the system s ability to discriminate between failure modes, (4) the Component Isolation Report demonstrates the system s ability to discriminate between failure modes relative to the components containing the failure modes, (5) the Sensor Sensor Sensitivity Analysis Report shows the diagnostic impact due to loss of sensor information, and (6) the Effect Mapping Report identifies failure modes that result in specified system-level effects.

  11. Radar network communication through sensing of frequency hopping

    DOEpatents

    Dowla, Farid; Nekoogar, Faranak

    2013-05-28

    In one embodiment, a radar communication system includes a plurality of radars having a communication range and being capable of operating at a sensing frequency and a reporting frequency, wherein the reporting frequency is different than the sensing frequency, each radar is adapted for operating at the sensing frequency until an event is detected, each radar in the plurality of radars has an identification/location frequency for reporting information different from the sensing frequency, a first radar of the radars which senses the event sends a reporting frequency corresponding to its identification/location frequency when the event is detected, and all other radars in the plurality of radars switch their reporting frequencies to match the reporting frequency of the first radar upon detecting the reporting frequency switch of a radar within the communication range. In another embodiment, a method is presented for communicating information in a radar system.

  12. Manpower Requirements Report for FY (Fiscal Year) 1984.

    DTIC Science & Technology

    1983-02-01

    capability to detect cannabis brings to seven the number of drugs detectable through urinaly- sis in the DoD system. While the detection and deterrence of... toxicology . The primary purpose of these con- ferences was validation of Legal sufficiency of the DoD laboratory system by the scientific community

  13. On the reliable use of satellite-derived surface water products for global flood monitoring

    NASA Astrophysics Data System (ADS)

    Hirpa, F. A.; Revilla-Romero, B.; Thielen, J.; Salamon, P.; Brakenridge, R.; Pappenberger, F.; de Groeve, T.

    2015-12-01

    Early flood warning and real-time monitoring systems play a key role in flood risk reduction and disaster response management. To this end, real-time flood forecasting and satellite-based detection systems have been developed at global scale. However, due to the limited availability of up-to-date ground observations, the reliability of these systems for real-time applications have not been assessed in large parts of the globe. In this study, we performed comparative evaluations of the commonly used satellite-based global flood detections and operational flood forecasting system using 10 major flood cases reported over three years (2012-2014). Specially, we assessed the flood detection capabilities of the near real-time global flood maps from the Global Flood Detection System (GFDS), and from the Moderate Resolution Imaging Spectroradiometer (MODIS), and the operational forecasts from the Global Flood Awareness System (GloFAS) for the major flood events recorded in global flood databases. We present the evaluation results of the global flood detection and forecasting systems in terms of correctly indicating the reported flood events and highlight the exiting limitations of each system. Finally, we propose possible ways forward to improve the reliability of large scale flood monitoring tools.

  14. Detection of infectious disease outbreaks in twenty-two fragile states, 2000-2010: a systematic review

    PubMed Central

    2011-01-01

    Fragile states are home to a sixth of the world's population, and their populations are particularly vulnerable to infectious disease outbreaks. Timely surveillance and control are essential to minimise the impact of these outbreaks, but little evidence is published about the effectiveness of existing surveillance systems. We did a systematic review of the circumstances (mode) of detection of outbreaks occurring in 22 fragile states in the decade 2000-2010 (i.e. all states consistently meeting fragility criteria during the timeframe of the review), as well as time lags from onset to detection of these outbreaks, and from detection to further events in their timeline. The aim of this review was to enhance the evidence base for implementing infectious disease surveillance in these complex, resource-constrained settings, and to assess the relative importance of different routes whereby outbreak detection occurs. We identified 61 reports concerning 38 outbreaks. Twenty of these were detected by existing surveillance systems, but 10 detections occurred following formal notifications by participating health facilities rather than data analysis. A further 15 outbreaks were detected by informal notifications, including rumours. There were long delays from onset to detection (median 29 days) and from detection to further events (investigation, confirmation, declaration, control). Existing surveillance systems yielded the shortest detection delays when linked to reduced barriers to health care and frequent analysis and reporting of incidence data. Epidemic surveillance and control appear to be insufficiently timely in fragile states, and need to be strengthened. Greater reliance on formal and informal notifications is warranted. Outbreak reports should be more standardised and enable monitoring of surveillance systems' effectiveness. PMID:21861869

  15. Insulation detection of electric vehicle batteries

    NASA Astrophysics Data System (ADS)

    Dai, Qiqi; Zhu, Zhongwen; Huang, Denggao; Du, Mingxing; Wei, Kexin

    2018-06-01

    In this paper, an electric vehicle insulation detection method with single side switching fixed resistance is designed, and the hardware and software design of the system are given. The experiment proves that the insulation detection system can detect the insulation resistance in a wide range of resistance values, and accurately report the fault level. This system can effectively monitor the insulation fault between the car body and the high voltage line and avoid the passengers from being injured.

  16. [Detection and classification of medication errors at Joan XXIII University Hospital].

    PubMed

    Jornet Montaña, S; Canadell Vilarrasa, L; Calabuig Mũoz, M; Riera Sendra, G; Vuelta Arce, M; Bardají Ruiz, A; Gallart Mora, M J

    2004-01-01

    Medication errors are multifactorial and multidisciplinary, and may originate in processes such as drug prescription, transcription, dispensation, preparation and administration. The goal of this work was to measure the incidence of detectable medication errors that arise within a unit dose drug distribution and control system, from drug prescription to drug administration, by means of an observational method confined to the Pharmacy Department, as well as a voluntary, anonymous report system. The acceptance of this voluntary report system's implementation was also assessed. A prospective descriptive study was conducted. Data collection was performed at the Pharmacy Department from a review of prescribed medical orders, a review of pharmaceutical transcriptions, a review of dispensed medication and a review of medication returned in unit dose medication carts. A voluntary, anonymous report system centralized in the Pharmacy Department was also set up to detect medication errors. Prescription errors were the most frequent (1.12%), closely followed by dispensation errors (1.04%). Transcription errors (0.42%) and administration errors (0.69%) had the lowest overall incidence. Voluntary report involved only 4.25% of all detected errors, whereas unit dose medication cart review contributed the most to error detection. Recognizing the incidence and types of medication errors that occur in a health-care setting allows us to analyze their causes and effect changes in different stages of the process in order to ensure maximal patient safety.

  17. Evaluation of a Web-based Error Reporting Surveillance System in a Large Iranian Hospital.

    PubMed

    Askarian, Mehrdad; Ghoreishi, Mahboobeh; Akbari Haghighinejad, Hourvash; Palenik, Charles John; Ghodsi, Maryam

    2017-08-01

    Proper reporting of medical errors helps healthcare providers learn from adverse incidents and improve patient safety. A well-designed and functioning confidential reporting system is an essential component to this process. There are many error reporting methods; however, web-based systems are often preferred because they can provide; comprehensive and more easily analyzed information. This study addresses the use of a web-based error reporting system. This interventional study involved the application of an in-house designed "voluntary web-based medical error reporting system." The system has been used since July 2014 in Nemazee Hospital, Shiraz University of Medical Sciences. The rate and severity of errors reported during the year prior and a year after system launch were compared. The slope of the error report trend line was steep during the first 12 months (B = 105.727, P = 0.00). However, it slowed following launch of the web-based reporting system and was no longer statistically significant (B = 15.27, P = 0.81) by the end of the second year. Most recorded errors were no-harm laboratory types and were due to inattention. Usually, they were reported by nurses and other permanent employees. Most reported errors occurred during morning shifts. Using a standardized web-based error reporting system can be beneficial. This study reports on the performance of an in-house designed reporting system, which appeared to properly detect and analyze medical errors. The system also generated follow-up reports in a timely and accurate manner. Detection of near-miss errors could play a significant role in identifying areas of system defects.

  18. Failure of the MicroScan WalkAway System To Detect Heteroresistance to Carbapenems in a Patient with Enterobacter aerogenes Bacteremia▿

    PubMed Central

    Gordon, N. C.; Wareham, D. W.

    2009-01-01

    We report the failure of the automated MicroScan WalkAway system to detect carbapenem heteroresistance in Enterobacter aerogenes. Carbapenem resistance has become an increasing concern in recent years, and robust surveillance is required to prevent dissemination of resistant strains. Reliance on automated systems may delay the detection of emerging resistance. PMID:19641071

  19. A prototype implementation of a network-level intrusion detection system. Technical report number CS91-11

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Heady, R.; Luger, G.F.; Maccabe, A.B.

    1991-05-15

    This paper presents the implementation of a prototype network level intrusion detection system. The prototype system monitors base level information in network packets (source, destination, packet size, time, and network protocol), learning the normal patterns and announcing anomalies as they occur. The goal of this research is to determine the applicability of current intrusion detection technology to the detection of network level intrusions. In particular, the authors are investigating the possibility of using this technology to detect and react to worm programs.

  20. Development of gas chromatographic methods for the analyses of organic carbonate-based electrolytes

    NASA Astrophysics Data System (ADS)

    Terborg, Lydia; Weber, Sascha; Passerini, Stefano; Winter, Martin; Karst, Uwe; Nowak, Sascha

    2014-01-01

    In this work, novel methods based on gas chromatography (GC) for the investigation of common organic carbonate-based electrolyte systems are presented, which are used in lithium ion batteries. The methods were developed for flame ionization detection (FID), mass spectrometric detection (MS). Further, headspace (HS) sampling for the investigation of solid samples like electrodes is reported. Limits of detection are reported for FID. Finally, the developed methods were applied to the electrolyte system of commercially available lithium ion batteries as well as on in-house assembled cells.

  1. Application of Knowledge Discovery in Databases Methodologies for Predictive Models for Pregnancy Adverse Events

    ERIC Educational Resources Information Center

    Taft, Laritza M.

    2010-01-01

    In its report "To Err is Human", The Institute of Medicine recommended the implementation of internal and external voluntary and mandatory automatic reporting systems to increase detection of adverse events. Knowledge Discovery in Databases (KDD) allows the detection of patterns and trends that would be hidden or less detectable if analyzed by…

  2. Value of evidence from syndromic surveillance with cumulative evidence from multiple data streams with delayed reporting.

    PubMed

    Struchen, R; Vial, F; Andersson, M G

    2017-04-26

    Delayed reporting of health data may hamper the early detection of infectious diseases in surveillance systems. Furthermore, combining multiple data streams, e.g. aiming at improving a system's sensitivity, can be challenging. In this study, we used a Bayesian framework where the result is presented as the value of evidence, i.e. the likelihood ratio for the evidence under outbreak versus baseline conditions. Based on a historical data set of routinely collected cattle mortality events, we evaluated outbreak detection performance (sensitivity, time to detection, in-control run length) under the Bayesian approach among three scenarios: presence of delayed data reporting, but not accounting for it; presence of delayed data reporting accounted for; and absence of delayed data reporting (i.e. an ideal system). Performance on larger and smaller outbreaks was compared with a classical approach, considering syndromes separately or combined. We found that the Bayesian approach performed better than the classical approach, especially for the smaller outbreaks. Furthermore, the Bayesian approach performed similarly well in the scenario where delayed reporting was accounted for to the scenario where it was absent. We argue that the value of evidence framework may be suitable for surveillance systems with multiple syndromes and delayed reporting of data.

  3. Fixed-point Design of the Lattice-reduction-aided Iterative Detection and Decoding Receiver for Coded MIMO Systems

    DTIC Science & Technology

    2011-01-01

    reliability, e.g., Turbo Codes [2] and Low Density Parity Check ( LDPC ) codes [3]. The challenge to apply both MIMO and ECC into wireless systems is on...REPORT Fixed-point Design of theLattice-reduction-aided Iterative Detection andDecoding Receiver for Coded MIMO Systems 14. ABSTRACT 16. SECURITY...illustrates the performance of coded LR aided detectors. 1. REPORT DATE (DD-MM-YYYY) 4. TITLE AND SUBTITLE 13. SUPPLEMENTARY NOTES The views, opinions

  4. A Simple System for the Early Detection of Breast Cancer

    DTIC Science & Technology

    2016-07-01

    AWARD NUMBER: W81XWH-14-1-0231 TITLE: A Simple System for Early Detection of Breast Cancer PRINCIPAL INVESTIGATOR: Stephen Johnston CONTRACTING...ADDRESS. 1. REPORT DATE July 2016 2. REPORT TYPE Annual 3. DATES COVERED 1Jul2015 - 30Jun2016 4. TITLE AND SUBTITLE A Simple System for the Early...Form 298 (Rev. 8-98) Prescribed by ANSI Std. Z39.18 W81XWH-14-1-0231 Abstract: We invented the immunosignature technology (IMS) as a simple , universal

  5. Simulating adverse event spontaneous reporting systems as preferential attachment networks: application to the Vaccine Adverse Event Reporting System.

    PubMed

    Scott, J; Botsis, T; Ball, R

    2014-01-01

    Spontaneous Reporting Systems [SRS] are critical tools in the post-licensure evaluation of medical product safety. Regulatory authorities use a variety of data mining techniques to detect potential safety signals in SRS databases. Assessing the performance of such signal detection procedures requires simulated SRS databases, but simulation strategies proposed to date each have limitations. We sought to develop a novel SRS simulation strategy based on plausible mechanisms for the growth of databases over time. We developed a simulation strategy based on the network principle of preferential attachment. We demonstrated how this strategy can be used to create simulations based on specific databases of interest, and provided an example of using such simulations to compare signal detection thresholds for a popular data mining algorithm. The preferential attachment simulations were generally structurally similar to our targeted SRS database, although they had fewer nodes of very high degree. The approach was able to generate signal-free SRS simulations, as well as mimicking specific known true signals. Explorations of different reporting thresholds for the FDA Vaccine Adverse Event Reporting System suggested that using proportional reporting ratio [PRR] > 3.0 may yield better signal detection operating characteristics than the more commonly used PRR > 2.0 threshold. The network analytic approach to SRS simulation based on the principle of preferential attachment provides an attractive framework for exploring the performance of safety signal detection algorithms. This approach is potentially more principled and versatile than existing simulation approaches. The utility of network-based SRS simulations needs to be further explored by evaluating other types of simulated signals with a broader range of data mining approaches, and comparing network-based simulations with other simulation strategies where applicable.

  6. Computer systems for automatic earthquake detection

    USGS Publications Warehouse

    Stewart, S.W.

    1974-01-01

    U.S Geological Survey seismologists in Menlo park, California, are utilizing the speed, reliability, and efficiency of minicomputers to monitor seismograph stations and to automatically detect earthquakes. An earthquake detection computer system, believed to be the only one of its kind in operation, automatically reports about 90 percent of all local earthquakes recorded by a network of over 100 central California seismograph stations. The system also monitors the stations for signs of malfunction or abnormal operation. Before the automatic system was put in operation, all of the earthquakes recorded had to be detected by manually searching the records, a time-consuming process. With the automatic detection system, the stations are efficiently monitored continuously. 

  7. A universal DNA-based protein detection system.

    PubMed

    Tran, Thua N N; Cui, Jinhui; Hartman, Mark R; Peng, Songming; Funabashi, Hisakage; Duan, Faping; Yang, Dayong; March, John C; Lis, John T; Cui, Haixin; Luo, Dan

    2013-09-25

    Protein immune detection requires secondary antibodies which must be carefully selected in order to avoid interspecies cross-reactivity, and is therefore restricted by the limited availability of primary/secondary antibody pairs. Here we present a versatile DNA-based protein detection system using a universal adapter to interface between IgG antibodies and DNA-modified reporter molecules. As a demonstration of this capability, we successfully used DNA nano-barcodes, quantum dots, and horseradish peroxidase enzyme to detect multiple proteins using our DNA-based labeling system. Our system not only eliminates secondary antibodies but also serves as a novel method platform for protein detection with modularity, high capacity, and multiplexed capability.

  8. A Universal DNA-Based Protein Detection System

    PubMed Central

    Tran, Thua N. N.; Cui, Jinhui; Hartman, Mark R.; Peng, Songming; Funabashi, Hisakage; Duan, Faping; Yang, Dayong; March, John C.; Lis, John T.; Cui, Haixin; Luo, Dan

    2014-01-01

    Protein immune detection requires secondary antibodies which must be carefully selected in order to avoid interspecies cross-reactivity, and is therefore restricted by the limited availability of primary/secondary antibody pairs. Here we present a versatile DNA-based protein detection system using a universal adapter to interface between IgG antibodies and DNA-modified reporter molecules. As a demonstration of this capability, we successfully used DNA nano-barcodes, quantum dots, and horseradish peroxidase enzyme to detect multiple proteins using our DNA-based labeling system. Our system not only eliminates secondary antibodies but also serves as a novel method platform for protein detection with modularity, high capacity, and multiplexed capability. PMID:23978265

  9. Towards an integrated defense system for cyber security situation awareness experiment

    NASA Astrophysics Data System (ADS)

    Zhang, Hanlin; Wei, Sixiao; Ge, Linqiang; Shen, Dan; Yu, Wei; Blasch, Erik P.; Pham, Khanh D.; Chen, Genshe

    2015-05-01

    In this paper, an implemented defense system is demonstrated to carry out cyber security situation awareness. The developed system consists of distributed passive and active network sensors designed to effectively capture suspicious information associated with cyber threats, effective detection schemes to accurately distinguish attacks, and network actors to rapidly mitigate attacks. Based on the collected data from network sensors, image-based and signals-based detection schemes are implemented to detect attacks. To further mitigate attacks, deployed dynamic firewalls on hosts dynamically update detection information reported from the detection schemes and block attacks. The experimental results show the effectiveness of the proposed system. A future plan to design an effective defense system is also discussed based on system theory.

  10. Decision support methods for the detection of adverse events in post-marketing data.

    PubMed

    Hauben, M; Bate, A

    2009-04-01

    Spontaneous reporting is a crucial component of post-marketing drug safety surveillance despite its significant limitations. The size and complexity of some spontaneous reporting system databases represent a challenge for drug safety professionals who traditionally have relied heavily on the scientific and clinical acumen of the prepared mind. Computer algorithms that calculate statistical measures of reporting frequency for huge numbers of drug-event combinations are increasingly used to support pharamcovigilance analysts screening large spontaneous reporting system databases. After an overview of pharmacovigilance and spontaneous reporting systems, we discuss the theory and application of contemporary computer algorithms in regular use, those under development, and the practical considerations involved in the implementation of computer algorithms within a comprehensive and holistic drug safety signal detection program.

  11. Alternative vehicle detection technologies for traffic signal systems : technical report.

    DOT National Transportation Integrated Search

    2009-02-01

    Due to the well-documented problems associated with inductive loops, most jurisdictions have : replaced many intersection loops with video image vehicle detection systems (VIVDS). While VIVDS : have overcome some of the problems with loops such as tr...

  12. Assessment of IVHS countermeasures for collision avoidance : rear-end crashes

    DOT National Transportation Integrated Search

    1993-05-01

    This report describe an analysis of the application of Intelligent : Vehicle Highway System (IVHS) technology to the reduction of rear-end crashes. The : principal countermeasure concept examined is a headway detection (HD) system that : would detect...

  13. Use of diaminofluoresceins to detect and measure nitric oxide in low level generating human immune cells.

    PubMed

    Tiscornia, Adriana; Cairoli, Ernesto; Marquez, Maria; Denicola, Ana; Pritsch, Otto; Cayota, Alfonso

    2009-03-15

    Nitric oxide ((*)NO) has been implicated in multiple physiological and pathological immune processes. Different methods have been developed to detect and quantify (*)NO, where one of the principal difficulties are the accurately detection in cellular system with low levels of (*)NO production. The choice of the (*)NO detection method to be used depends on the characteristics of the experimental system and the levels of (*)NO production which depend on either the organism source of samples or the experimental conditions. Recently, high sensitive methods to detect and image (*)NO have been reported using 4,5-diaminofluorescein-based fluorescent probes (DAF) and its derivate 4,5-diaminofluorescein diacetate (DAF-2 DA). This work was aimed to adapt and optimize the use of DAF probes to detect and quantify the (*)NO production in systems of high, moderate and low out-put production, especially in human PBMC and their subpopulations. Here, we report an original experimental design which is useful to detect and estimate (*)NO fluxes in human PBMC and their subpopulations with high specificity and sensitivity.

  14. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jackson, K.A.; Neuman, M.C.; Simmonds, D.D.

    An effective method for detecting computer misuse is the automatic monitoring and analysis of on-line user activity. This activity is reflected in the system audit record, in the system vulnerability posture, and in other evidence found through active testing of the system. During the last several years we have implemented an automatic misuse detection system at Los Alamos. This is the Network Anomaly Detection and Intrusion Reporter (NADIR). We are currently expanding NADIR to include processing of the Cray UNICOS operating system. This new component is called the UNICOS Realtime NADIR, or UNICORN. UNICORN summarizes user activity and system configurationmore » in statistical profiles. It compares these profiles to expert rules that define security policy and improper or suspicious behavior. It reports suspicious behavior to security auditors and provides tools to aid in follow-up investigations. The first phase of UNICORN development is nearing completion, and will be operational in late 1994.« less

  15. A system for distributed intrusion detection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Snapp, S.R.; Brentano, J.; Dias, G.V.

    1991-01-01

    The study of providing security in computer networks is a rapidly growing area of interest because the network is the medium over which most attacks or intrusions on computer systems are launched. One approach to solving this problem is the intrusion-detection concept, whose basic premise is that not only abandoning the existing and huge infrastructure of possibly-insecure computer and network systems is impossible, but also replacing them by totally-secure systems may not be feasible or cost effective. Previous work on intrusion-detection systems were performed on stand-alone hosts and on a broadcast local area network (LAN) environment. The focus of ourmore » present research is to extend our network intrusion-detection concept from the LAN environment to arbitarily wider areas with the network topology being arbitrary as well. The generalized distributed environment is heterogeneous, i.e., the network nodes can be hosts or servers from different vendors, or some of them could be LAN managers, like our previous work, a network security monitor (NSM), as well. The proposed architecture for this distributed intrusion-detection system consists of the following components: a host manager in each host; a LAN manager for monitoring each LAN in the system; and a central manager which is placed at a single secure location and which receives reports from various host and LAN managers to process these reports, correlate them, and detect intrusions. 11 refs., 2 figs.« less

  16. Detection of vulnerable neurons damaged by environmental insults in utero

    PubMed Central

    Torii, Masaaki; Chang, Yu-Wen; Ishii, Seiji; Waxman, Stephen G.; Kocsis, Jeffery D.; Rakic, Pasko; Hashimoto-Torii, Kazue

    2017-01-01

    Development of prognostic biomarkers for the detection of prenatally damaged neurons before manifestations of postnatal disorders is an essential step for prevention and treatment of susceptible individuals. We have developed a versatile fluorescence reporter system in mice enabling detection of Heat Shock Factor 1 activation in response to prenatal cellular damage caused by exposure to various harmful chemical or physical agents. Using an intrautero electroporation-mediated reporter assay and transgenic reporter mice, we are able to identify neurons that survive prenatal exposure to harmful agents but remain vulnerable in postnatal life. This system may provide a powerful tool for exploring the pathogenesis and treatment of multiple disorders caused by exposure to environmental stress before symptoms become manifested, exacerbated, and/or irreversible. PMID:28123061

  17. Procarcinogens – Determination and Evaluation by Yeast-Based Biosensor Transformed with Plasmids Incorporating RAD54 Reporter Construct and Cytochrome P450 Genes

    PubMed Central

    Bui, Van Ngoc; Nguyen, Thi Thu Huyen; Mai, Chi Thanh; Bettarel, Yvan; Hoang, Thi Yen; Trinh, Thi Thuy Linh; Truong, Nam Hai; Chu, Hoang Ha; Nguyen, Vu Thanh Thanh; Nguyen, Huu Duc

    2016-01-01

    In Vietnam, a great number of toxic substances, including carcinogens and procarcinogens, from industrial and agricultural activities, food production, and healthcare services are daily released into the environment. In the present study, we report the development of novel yeast-based biosensor systems to determine both genotoxic carcinogens and procarcinogens by cotransformation with two plasmids. One plasmid is carrying human CPR and CYP (CYP3A4, CYP2B6, or CYP2D6) genes, while the other contains the RAD54-GFP reporter construct. The three resulting coexpression systems bearing both CPR-CYP and RAD54-GFP expression cassettes were designated as CYP3A4/CYP2B6/CYP2D6 + RAD54 systems, respectively and used to detect and evaluate the genotoxic potential of carcinogens and procarcinogens by selective activation and induction of both CPR-CYP and RAD54-GFP expression cassettes in response to DNA damage. Procarcinogens were shown to be predominantly, moderately or not bioactivated by one of the CYP enzymes and thus selectively detected by the specific coexpression system. Aflatoxin B1 and benzo(a)pyrene were predominantly detected by the CYP3A4 + RAD54 system, while N-nitrosodimethylamine only moderately activated the CYP2B6 + RAD54 reporter system and none of them was identified by the CYP2D6 + RAD54 system. In contrast, the genotoxic carcinogen, methyl methanesulfonate, was detected by all systems. Our yeast-reporter system can be performed in 384-well microplates to provide efficient genotoxicity testing to identify various carcinogenic compounds and reduce chemical consumption to about 53% as compared with existing 96-well genotoxicity bioassays. In association with a liquid handling robot, this platform enables rapid, cost-effective, and high-throughput screening of numerous analytes in a fully automated and continuous manner without the need for user interaction. PMID:28006013

  18. An integrated real-time health monitoring and impact/collision detection system for bridges in cold remote regions.

    DOT National Transportation Integrated Search

    2015-03-01

    This report presents a research examining the feasibility of creating an integrated structural health : monitoring and impact/collision detection system for bridges in remote cold regions, where in-person : inspection becomes formidable. The research...

  19. Ice detection systems : experimental feature : final report.

    DOT National Transportation Integrated Search

    1986-01-01

    In the fall of 1980, an experimental ice detection system was installed on the Fremont Bridge in Portland, Oregon. this bridge, which caries I-405 over the Willamette River, has a history of icing problem when the deck is wet and the temperature hove...

  20. Intrusion Detection System Visualization of Network Alerts

    DTIC Science & Technology

    2010-07-01

    Intrusion Detection System Visualization of Network Alerts Dolores M. Zage and Wayne M. Zage Ball State University Final Report July 2010...contracts. Staff Wayne Zage, Director of the S2ERC and Professor, Department of Computer Science, Ball State University Dolores Zage, Research

  1. A fibre optic fluorescence sensor to measure redox level in tissues

    NASA Astrophysics Data System (ADS)

    Zhang, Wen Qi; Morrison, Janna L.; Darby, Jack R. T.; Plush, Sally; Sorvina, Alexandra; Brooks, Doug; Monro, Tanya M.; Afshar Vahid, Shahraam

    2018-01-01

    We report the design of a fibre optic-based redox detection system for investigating differences in metabolic activities of tissues. Our system shows qualitative agreement with the results collected from a commercial two- photon microscope system. Thus, demonstrating the feasibility of building an ex vivo and in vivo redox detection system that is low cost and portable.

  2. Detection of coal mine workings using high-resolution earth resistivity techniques. Final technical report, September 1979-September 1980

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Peters, W.R.; Campbell, T.M.; Sturdivant, V.R.

    1980-09-26

    Shallow underground voids resulting from early coal mining and other resource recovery activities over the past several decades are now being recognized as a significant cause of ground subsidence problems in developing urban areas. Uncertain knowledge of abandoned coal mines also imposes potential hazards in coal excavation operations since water inundation or the release of methane gas is a principal hazard when mine excavation operations break into an abandoned mine. US Army requirements for an effective method for detecting and mapping subversive abandoned tunnels have resulted in a surface-operated automatic earth resistivity survey system with a digital computer data processingmore » system. Field tests aimed at demonstrating the system performance resulted in successful detection of tunnels having depth-to-diameter ratios up to 15 to 1. Under the sponsorship of the Bureau of Mines, a similar system was designed and constructed for use in the detection of coal mine workings. This report discusses the hardware and software aspects of the system and the application of the high-resolution earth resistivity method to the survey and mapping of abandoned coal mine workings. In the field tests reported, the targets of interest were both air- and water-filled workings.« less

  3. Algorithms used in the Airborne Lidar Processing System (ALPS)

    USGS Publications Warehouse

    Nagle, David B.; Wright, C. Wayne

    2016-05-23

    The Airborne Lidar Processing System (ALPS) analyzes Experimental Advanced Airborne Research Lidar (EAARL) data—digitized laser-return waveforms, position, and attitude data—to derive point clouds of target surfaces. A full-waveform airborne lidar system, the EAARL seamlessly and simultaneously collects mixed environment data, including submerged, sub-aerial bare earth, and vegetation-covered topographies.ALPS uses three waveform target-detection algorithms to determine target positions within a given waveform: centroid analysis, leading edge detection, and bottom detection using water-column backscatter modeling. The centroid analysis algorithm detects opaque hard surfaces. The leading edge algorithm detects topography beneath vegetation and shallow, submerged topography. The bottom detection algorithm uses water-column backscatter modeling for deeper submerged topography in turbid water.The report describes slant range calculations and explains how ALPS uses laser range and orientation measurements to project measurement points into the Universal Transverse Mercator coordinate system. Parameters used for coordinate transformations in ALPS are described, as are Interactive Data Language-based methods for gridding EAARL point cloud data to derive digital elevation models. Noise reduction in point clouds through use of a random consensus filter is explained, and detailed pseudocode, mathematical equations, and Yorick source code accompany the report.

  4. Assessing the mandatory bovine abortion notification system in France using unilist capture-recapture approach.

    PubMed

    Bronner, Anne; Hénaux, Viviane; Vergne, Timothée; Vinard, Jean-Luc; Morignat, Eric; Hendrikx, Pascal; Calavas, Didier; Gay, Emilie

    2013-01-01

    The mandatory bovine abortion notification system in France aims to detect as soon as possible any resurgence of bovine brucellosis. However, under-reporting seems to be a major limitation of this system. We used a unilist capture-recapture approach to assess the sensitivity, i.e. the proportion of farmers who reported at least one abortion among those who detected such events, and representativeness of the system during 2006-2011. We implemented a zero-inflated Poisson model to estimate the proportion of farmers who detected at least one abortion, and among them, the proportion of farmers not reporting. We also applied a hurdle model to evaluate the effect of factors influencing the notification process. We found that the overall surveillance sensitivity was about 34%, and was higher in beef than dairy cattle farms. The observed increase in the proportion of notifying farmers from 2007 to 2009 resulted from an increase in the surveillance sensitivity in 2007/2008 and an increase in the proportion of farmers who detected at least one abortion in 2008/2009. These patterns suggest a raise in farmers' awareness in 2007/2008 when the Bluetongue Virus (BTV) was detected in France, followed by an increase in the number of abortions in 2008/2009 as BTV spread across the country. Our study indicated a lack of sensitivity of the mandatory bovine abortion notification system, raising concerns about the ability to detect brucellosis outbreaks early. With the increasing need to survey the zoonotic Rift Valley Fever and Q fever diseases that may also cause bovine abortions, our approach is of primary interest for animal health stakeholders to develop information programs to increase abortion notifications. Our framework combining hurdle and ZIP models may also be applied to estimate the completeness of other clinical surveillance systems.

  5. Assessing the Mandatory Bovine Abortion Notification System in France Using Unilist Capture-Recapture Approach

    PubMed Central

    Bronner, Anne; Hénaux, Viviane; Vergne, Timothée; Vinard, Jean-Luc; Morignat, Eric; Hendrikx, Pascal; Calavas, Didier; Gay, Emilie

    2013-01-01

    The mandatory bovine abortion notification system in France aims to detect as soon as possible any resurgence of bovine brucellosis. However, under-reporting seems to be a major limitation of this system. We used a unilist capture-recapture approach to assess the sensitivity, i.e. the proportion of farmers who reported at least one abortion among those who detected such events, and representativeness of the system during 2006–2011. We implemented a zero-inflated Poisson model to estimate the proportion of farmers who detected at least one abortion, and among them, the proportion of farmers not reporting. We also applied a hurdle model to evaluate the effect of factors influencing the notification process. We found that the overall surveillance sensitivity was about 34%, and was higher in beef than dairy cattle farms. The observed increase in the proportion of notifying farmers from 2007 to 2009 resulted from an increase in the surveillance sensitivity in 2007/2008 and an increase in the proportion of farmers who detected at least one abortion in 2008/2009. These patterns suggest a raise in farmers’ awareness in 2007/2008 when the Bluetongue Virus (BTV) was detected in France, followed by an increase in the number of abortions in 2008/2009 as BTV spread across the country. Our study indicated a lack of sensitivity of the mandatory bovine abortion notification system, raising concerns about the ability to detect brucellosis outbreaks early. With the increasing need to survey the zoonotic Rift Valley Fever and Q fever diseases that may also cause bovine abortions, our approach is of primary interest for animal health stakeholders to develop information programs to increase abortion notifications. Our framework combining hurdle and ZIP models may also be applied to estimate the completeness of other clinical surveillance systems. PMID:23691004

  6. Evaluation of Incident Detection Methodologies

    DOT National Transportation Integrated Search

    1999-10-01

    Original Report Date: October 1998. The detection of freeway incidents is an essential element of an area's traffic management system. Incidents need to be detected and handled as promptly as possible to minimize delay to the public. Various algorith...

  7. A Bayesian system to detect and characterize overlapping outbreaks.

    PubMed

    Aronis, John M; Millett, Nicholas E; Wagner, Michael M; Tsui, Fuchiang; Ye, Ye; Ferraro, Jeffrey P; Haug, Peter J; Gesteland, Per H; Cooper, Gregory F

    2017-09-01

    Outbreaks of infectious diseases such as influenza are a significant threat to human health. Because there are different strains of influenza which can cause independent outbreaks, and influenza can affect demographic groups at different rates and times, there is a need to recognize and characterize multiple outbreaks of influenza. This paper describes a Bayesian system that uses data from emergency department patient care reports to create epidemiological models of overlapping outbreaks of influenza. Clinical findings are extracted from patient care reports using natural language processing. These findings are analyzed by a case detection system to create disease likelihoods that are passed to a multiple outbreak detection system. We evaluated the system using real and simulated outbreaks. The results show that this approach can recognize and characterize overlapping outbreaks of influenza. We describe several extensions that appear promising. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. A novel sensitive pathogen detection system based on Microbead Quantum Dot System.

    PubMed

    Wu, Tzong-Yuan; Su, Yi-Yu; Shu, Wei-Hsien; Mercado, Augustus T; Wang, Shi-Kwun; Hsu, Ling-Yi; Tsai, Yow-Fu; Chen, Chung-Yung

    2016-04-15

    A fast and accurate detection system for pathogens can provide immediate measurements for the identification of infectious agents. Therefore, the Microbead Quantum-dots Detection System (MQDS) was developed to identify and measure target DNAs of pathogenic microorganisms and eliminated the need of PCR amplifications. This nanomaterial-based technique can detect different microorganisms by flow cytometry measurements. In MQDS, pathogen specific DNA probes were designed to form a hairpin structure and conjugated on microbeads. In the presence of the complementary target DNA sequence, the probes will compete for binding with the reporter probes but will not interfere with the binding between the probe and internal control DNA. To monitor the binding process by flow cytometry, both the reporter probes and internal control probes were conjugated with Quantum dots that fluoresce at different emission wavelengths using the click reaction. When MQDS was used to detect the pathogens in environmental samples, a high correlation coefficient (R=0.994) for Legionella spp., with a detection limit of 0.1 ng of the extracted DNAs and 10 CFU/test, can be achieved. Thus, this newly developed technique can also be applied to detect other pathogens, particularly viruses and other genetic diseases. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Smartphone-based portable biosensing system using impedance measurement with printed electrodes for 2,4,6-trinitrotoluene (TNT) detection.

    PubMed

    Zhang, Diming; Jiang, Jing; Chen, Junye; Zhang, Qian; Lu, Yanli; Yao, Yao; Li, Shuang; Logan Liu, Gang; Liu, Qingjun

    2015-08-15

    Rapid, sensitive, selective and portable detection of 2,4,6-trinitrotoluene (TNT) is in high demand for public safety and environmental monitoring. In this study, we reported a smartphone-based system using impedance monitoring for TNT detection. The screen-printed electrodes modified with TNT-specific peptides were used as disposable a biosensor to produce impedance responses to TNT. The responses could be monitored by a hand-held device and send out to smartphone through Bluetooth. Then, the smartphone was used to display TNT responses in real time and report concentration finally. In the measurement, the system was demonstrated to detect TNT at concentration as low as 10(-6) M and distinguish TNT versus different chemicals in high specificity. Thus, the smartphone-based biosensing platform provided a convenient and efficient approach to design portable instruments for chemical detections such as TNT recognition. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Detecting Signals of Disproportionate Reporting from Singapore's Spontaneous Adverse Event Reporting System: An Application of the Sequential Probability Ratio Test.

    PubMed

    Chan, Cheng Leng; Rudrappa, Sowmya; Ang, Pei San; Li, Shu Chuen; Evans, Stephen J W

    2017-08-01

    The ability to detect safety concerns from spontaneous adverse drug reaction reports in a timely and efficient manner remains important in public health. This paper explores the behaviour of the Sequential Probability Ratio Test (SPRT) and ability to detect signals of disproportionate reporting (SDRs) in the Singapore context. We used SPRT with a combination of two hypothesised relative risks (hRRs) of 2 and 4.1 to detect signals of both common and rare adverse events in our small database. We compared SPRT with other methods in terms of number of signals detected and whether labelled adverse drug reactions were detected or the reaction terms were considered serious. The other methods used were reporting odds ratio (ROR), Bayesian Confidence Propagation Neural Network (BCPNN) and Gamma Poisson Shrinker (GPS). The SPRT produced 2187 signals in common with all methods, 268 unique signals, and 70 signals in common with at least one other method, and did not produce signals in 178 cases where two other methods detected them, and there were 403 signals unique to one of the other methods. In terms of sensitivity, ROR performed better than other methods, but the SPRT method found more new signals. The performances of the methods were similar for negative predictive value and specificity. Using a combination of hRRs for SPRT could be a useful screening tool for regulatory agencies, and more detailed investigation of the medical utility of the system is merited.

  11. The Architecture Design of Detection and Calibration System for High-voltage Electrical Equipment

    NASA Astrophysics Data System (ADS)

    Ma, Y.; Lin, Y.; Yang, Y.; Gu, Ch; Yang, F.; Zou, L. D.

    2018-01-01

    With the construction of Material Quality Inspection Center of Shandong electric power company, Electric Power Research Institute takes on more jobs on quality analysis and laboratory calibration for high-voltage electrical equipment, and informationization construction becomes urgent. In the paper we design a consolidated system, which implements the electronic management and online automation process for material sampling, test apparatus detection and field test. In the three jobs we use QR code scanning, online Word editing and electronic signature. These techniques simplify the complex process of warehouse management and testing report transferring, and largely reduce the manual procedure. The construction of the standardized detection information platform realizes the integrated management of high-voltage electrical equipment from their networking, running to periodic detection. According to system operation evaluation, the speed of transferring report is doubled, and querying data is also easier and faster.

  12. A Participatory System for Preventing Pandemics of Animal Origins: Pilot Study of the Participatory One Health Disease Detection (PODD) System

    PubMed Central

    Yano, Terdsak; Phornwisetsirikun, Somphorn; Susumpow, Patipat; Visrutaratna, Surasing; Chanachai, Karoon; Phetra, Polawat; Chaisowwong, Warangkhana; Trakarnsirinont, Pairat; Hemwan, Phonpat; Kaewpinta, Boontuan; Singhapreecha, Charuk; Kreausukon, Khwanchai; Charoenpanyanet, Arisara ; Robert, Chongchit Sripun; Robert, Lamar; Rodtian, Pranee; Mahasing, Suteerat; Laiya, Ekkachai; Pattamakaew, Sakulrat; Tankitiyanon, Taweesart; Sansamur, Chalutwan

    2018-01-01

    Background Aiming for early disease detection and prompt outbreak control, digital technology with a participatory One Health approach was used to create a novel disease surveillance system called Participatory One Health Disease Detection (PODD). PODD is a community-owned surveillance system that collects data from volunteer reporters; identifies disease outbreak automatically; and notifies the local governments (LGs), surrounding villages, and relevant authorities. This system provides a direct and immediate benefit to the communities by empowering them to protect themselves. Objective The objective of this study was to determine the effectiveness of the PODD system for the rapid detection and control of disease outbreaks. Methods The system was piloted in 74 LGs in Chiang Mai, Thailand, with the participation of 296 volunteer reporters. The volunteers and LGs were key participants in the piloting of the PODD system. Volunteers monitored animal and human diseases, as well as environmental problems, in their communities and reported these events via the PODD mobile phone app. LGs were responsible for outbreak control and provided support to the volunteers. Outcome mapping was used to evaluate the performance of the LGs and volunteers. Results LGs were categorized into one of the 3 groups based on performance: A (good), B (fair), and C (poor), with the majority (46%,34/74) categorized into group B. Volunteers were similarly categorized into 4 performance groups (A-D), again with group A showing the best performance, with the majority categorized into groups B and C. After 16 months of implementation, 1029 abnormal events had been reported and confirmed to be true reports. The majority of abnormal reports were sick or dead animals (404/1029, 39.26%), followed by zoonoses and other human diseases (129/1029, 12.54%). Many potentially devastating animal disease outbreaks were detected and successfully controlled, including 26 chicken high mortality outbreaks, 4 cattle disease outbreaks, 3 pig disease outbreaks, and 3 fish disease outbreaks. In all cases, the communities and animal authorities cooperated to apply community contingency plans to control these outbreaks, and community volunteers continued to monitor the abnormal events for 3 weeks after each outbreak was controlled. Conclusions By design, PODD initially targeted only animal diseases that potentially could emerge into human pandemics (eg, avian influenza) and then, in response to community needs, expanded to cover human health and environmental health issues. PMID:29563079

  13. Evaluation of Epidemic Intelligence Systems Integrated in the Early Alerting and Reporting Project for the Detection of A/H5N1 Influenza Events

    PubMed Central

    Barboza, Philippe; Vaillant, Laetitia; Mawudeku, Abla; Nelson, Noele P.; Hartley, David M.; Madoff, Lawrence C.; Linge, Jens P.; Collier, Nigel; Brownstein, John S.; Yangarber, Roman; Astagneau, Pascal; on behalf of the Early Alerting, Reporting Project of the Global Health Security Initiative

    2013-01-01

    The objective of Web-based expert epidemic intelligence systems is to detect health threats. The Global Health Security Initiative (GHSI) Early Alerting and Reporting (EAR) project was launched to assess the feasibility and opportunity for pooling epidemic intelligence data from seven expert systems. EAR participants completed a qualitative survey to document epidemic intelligence strategies and to assess perceptions regarding the systems performance. Timeliness and sensitivity were rated highly illustrating the value of the systems for epidemic intelligence. Weaknesses identified included representativeness, completeness and flexibility. These findings were corroborated by the quantitative analysis performed on signals potentially related to influenza A/H5N1 events occurring in March 2010. For the six systems for which this information was available, the detection rate ranged from 31% to 38%, and increased to 72% when considering the virtual combined system. The effective positive predictive values ranged from 3% to 24% and F1-scores ranged from 6% to 27%. System sensitivity ranged from 38% to 72%. An average difference of 23% was observed between the sensitivities calculated for human cases and epizootics, underlining the difficulties in developing an efficient algorithm for a single pathology. However, the sensitivity increased to 93% when the virtual combined system was considered, clearly illustrating complementarities between individual systems. The average delay between the detection of A/H5N1 events by the systems and their official reporting by WHO or OIE was 10.2 days (95% CI: 6.7–13.8). This work illustrates the diversity in implemented epidemic intelligence activities, differences in system's designs, and the potential added values and opportunities for synergy between systems, between users and between systems and users. PMID:23472077

  14. Evaluation of epidemic intelligence systems integrated in the early alerting and reporting project for the detection of A/H5N1 influenza events.

    PubMed

    Barboza, Philippe; Vaillant, Laetitia; Mawudeku, Abla; Nelson, Noele P; Hartley, David M; Madoff, Lawrence C; Linge, Jens P; Collier, Nigel; Brownstein, John S; Yangarber, Roman; Astagneau, Pascal

    2013-01-01

    The objective of Web-based expert epidemic intelligence systems is to detect health threats. The Global Health Security Initiative (GHSI) Early Alerting and Reporting (EAR) project was launched to assess the feasibility and opportunity for pooling epidemic intelligence data from seven expert systems. EAR participants completed a qualitative survey to document epidemic intelligence strategies and to assess perceptions regarding the systems performance. Timeliness and sensitivity were rated highly illustrating the value of the systems for epidemic intelligence. Weaknesses identified included representativeness, completeness and flexibility. These findings were corroborated by the quantitative analysis performed on signals potentially related to influenza A/H5N1 events occurring in March 2010. For the six systems for which this information was available, the detection rate ranged from 31% to 38%, and increased to 72% when considering the virtual combined system. The effective positive predictive values ranged from 3% to 24% and F1-scores ranged from 6% to 27%. System sensitivity ranged from 38% to 72%. An average difference of 23% was observed between the sensitivities calculated for human cases and epizootics, underlining the difficulties in developing an efficient algorithm for a single pathology. However, the sensitivity increased to 93% when the virtual combined system was considered, clearly illustrating complementarities between individual systems. The average delay between the detection of A/H5N1 events by the systems and their official reporting by WHO or OIE was 10.2 days (95% CI: 6.7-13.8). This work illustrates the diversity in implemented epidemic intelligence activities, differences in system's designs, and the potential added values and opportunities for synergy between systems, between users and between systems and users.

  15. Crystal growth furnace safety system validation

    NASA Technical Reports Server (NTRS)

    Mackowski, D. W.; Hartfield, R.; Bhavnani, S. H.; Belcher, V. M.

    1994-01-01

    The findings are reported regarding the safe operation of the NASA crystal growth furnace (CGF) and potential methods for detecting containment failures of the furnace. The main conclusions are summarized by ampoule leak detection, cartridge leak detection, and detection of hazardous species in the experiment apparatus container (EAC).

  16. Rail integrity alert system (RIAS) feature discrimination : final report.

    DOT National Transportation Integrated Search

    2016-08-01

    This report describes GE Global Researchs research, in partnership with GE Transportation, into developing and deploying : algorithms for a locomotive-based inductive sensing system that has a very high probability of detecting broken rails with v...

  17. Detecting, reporting, and analysis of priority diseases for routine public health surveillance in Liberia.

    PubMed

    Frimpong, Joseph Asamoah; Park, Meeyoung Mattie; Amo-Addae, Maame Pokuah; Adewuyi, Peter Adebayo; Nagbe, Thomas Knue

    2017-01-01

    An essential component of a public health surveillance system is its ability to detect priority diseases which fall within the mandate of public health officials at all levels. Early detection, reporting and response to public health events help to reduce the burden of mortality and morbidity on communities. Analysis of reliable surveillance data provides relevant information which can enable implementation of timely and appropriate public health interventions. To ensure that a resilient system is in place, the World Health Organization (WHO) has provided guidelines for detection, reporting and response to public health events in the Integrated Disease Surveillance and Response (IDSR) strategy. This case study provides training on detection, reporting and analysis of priority diseases for routine public health surveillance in Liberia and highlights potential errors and challenges which can hinder effective surveillance. Table-top exercises and group discussion lead participants through a simulated verification and analyses of summary case reports in the role of the District Surveillance Officer. This case study is intended for public health training in a classroom setting and can be accomplished within 2 hours 30 minutes. The target audience include residents in Frontline Epidemiology Training Programs (FETP-Frontline), Field Epidemiology and Laboratory Training Programs (FELTPs), and others who are interested in this topic.

  18. FINDS: A fault inferring nonlinear detection system programmers manual, version 3.0

    NASA Technical Reports Server (NTRS)

    Lancraft, R. E.

    1985-01-01

    Detailed software documentation of the digital computer program FINDS (Fault Inferring Nonlinear Detection System) Version 3.0 is provided. FINDS is a highly modular and extensible computer program designed to monitor and detect sensor failures, while at the same time providing reliable state estimates. In this version of the program the FINDS methodology is used to detect, isolate, and compensate for failures in simulated avionics sensors used by the Advanced Transport Operating Systems (ATOPS) Transport System Research Vehicle (TSRV) in a Microwave Landing System (MLS) environment. It is intended that this report serve as a programmers guide to aid in the maintenance, modification, and revision of the FINDS software.

  19. 46 CFR 27.209 - What are the requirements for training crews to respond to fires?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... the engine room and effectively seal all natural openings to the space to prevent leakage of the.... (3) Reporting inoperative alarm systems and fire-detection systems. (4) Putting on a fireman's outfit...) Testing of all alarm and detection systems; and (4) Putting on protective clothing (by at least one person...

  20. Development of a Sensitive Luciferase-Based Sandwich ELISA System for the Detection of Human Extracellular Matrix 1 Protein.

    PubMed

    Li, Ya; Li, Yanqing; Zhao, Junli; Zheng, Xiaojing; Mao, Qinwen; Xia, Haibin

    2016-12-01

    Enzyme-linked immunosorbent assay (ELISA) has been one of the main methods for detecting an antigen in an aqueous sample for more than four decades. Nowadays, one of the biggest concerns for ELISA is still how to improve the sensitivity of the assay, and the luciferase-luciferin reaction system has been noticed as a new detection method with high sensitivity. In this study, a luciferin-luciferase reaction system was used as the detection method for a sandwich ELISA system. It was shown that this new system led to an increase in the detection sensitivity of at least two times when compared with the traditional horseradish peroxidase (HRP) detection method. Lastly, the serum levels of the human extracellular matrix 1 protein of breast cancer patients were determined by the new system, which were overall similar to the HRP chemiluminescent system. Furthermore, this new luciferase reporter can be implemented into other ELISA systems for the purpose of increasing the assay sensitivity.

  1. A Crime Analysis Decision Support System for Crime Report Classification and Visualization

    ERIC Educational Resources Information Center

    Ku, Chih-Hao

    2012-01-01

    Today's Internet-based crime reporting systems make timely and anonymous crime reporting possible. However, these reports also result in a rapidly growing set of unstructured text files. Complicating the problem is that the information has not been filtered or guided in a detective-led interview resulting in much irrelevant information. To…

  2. Unmanned Aerial Vehicle Non Line of Sight Chemical Detection Final Report

    DTIC Science & Technology

    2016-12-01

    aircraft system that is used to perform point detection of chemical warfare agents and collection of vapor, liquid, and solid samples. A modular payload...Standoff Quadcopter Unmanned aircraft system Modular payload 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT 18. NUMBER OF...Manufacturing Division, modular payloads are being developed to perform point detection and CBRNE sampling. The available UAS is a quadcopter capable of

  3. Design of an infrared camera based aircraft detection system for laser guide star installations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Friedman, H.; Macintosh, B.

    1996-03-05

    There have been incidents in which the irradiance resulting from laser guide stars have temporarily blinded pilots or passengers of aircraft. An aircraft detection system based on passive near infrared cameras (instead of active radar) is described in this report.

  4. Airborne Laser Remote Sensor for Oil Detection and Classification : Engineering Requirements and Technical Considerations Relevant to a Performance Specification

    DOT National Transportation Integrated Search

    1975-08-01

    This report outlines the engineering requirements for an Airborne Laser Remote Sensor for Oil Detection and Classification System. Detailed engineering requirements are given for the major units of the system. Technical considerations pertinent to a ...

  5. A Distributed, Collaborative Intelligent Agent System Approach for Proactive Postmarketing Drug Safety Surveillance

    PubMed Central

    Ji, Yanqing; Ying, Hao; Farber, Margo S.; Yen, John; Dews, Peter; Miller, Richard E.; Massanari, R. Michael

    2014-01-01

    Discovering unknown adverse drug reactions (ADRs) in postmarketing surveillance as early as possible is of great importance. The current approach to postmarketing surveillance primarily relies on spontaneous reporting. It is a passive surveillance system and limited by gross underreporting (<10% reporting rate), latency, and inconsistent reporting. We propose a novel team-based intelligent agent software system approach for proactively monitoring and detecting potential ADRs of interest using electronic patient records. We designed such a system and named it ADRMonitor. The intelligent agents, operating on computers located in different places, are capable of continuously and autonomously collaborating with each other and assisting the human users (e.g., the food and drug administration (FDA), drug safety professionals, and physicians). The agents should enhance current systems and accelerate early ADR identification. To evaluate the performance of the ADRMonitor with respect to the current spontaneous reporting approach, we conducted simulation experiments on identification of ADR signal pairs (i.e., potential links between drugs and apparent adverse reactions) under various conditions. The experiments involved over 275 000 simulated patients created on the basis of more than 1000 real patients treated by the drug cisapride that was on the market for seven years until its withdrawal by the FDA in 2000 due to serious ADRs. Healthcare professionals utilizing the spontaneous reporting approach and the ADRMonitor were separately simulated by decision-making models derived from a general cognitive decision model called fuzzy recognition-primed decision (RPD) model that we recently developed. The quantitative simulation results show that 1) the number of true ADR signal pairs detected by the ADRMonitor is 6.6 times higher than that by the spontaneous reporting strategy; 2) the ADR detection rate of the ADRMonitor agents with even moderate decision-making skills is five times higher than that of spontaneous reporting; and 3) as the number of patient cases increases, ADRs could be detected significantly earlier by the ADRMonitor. PMID:20007038

  6. Swalley canal ice detection system : final report.

    DOT National Transportation Integrated Search

    1990-01-01

    This report evaluates the reliability of information provided by a "SCAN 16" surface condition analyzer. SCAN systems are designed to inform highway maintenance personnel when frost, ice and snow are present on a roadway surface or bridge deck. The s...

  7. Corrections of clinical chemistry test results in a laboratory information system.

    PubMed

    Wang, Sihe; Ho, Virginia

    2004-08-01

    The recently released reports by the Institute of Medicine, To Err Is Human and Patient Safety, have received national attention because of their focus on the problem of medical errors. Although a small number of studies have reported on errors in general clinical laboratories, there are, to our knowledge, no reported studies that focus on errors in pediatric clinical laboratory testing. To characterize the errors that have caused corrections to have to be made in pediatric clinical chemistry results in the laboratory information system, Misys. To provide initial data on the errors detected in pediatric clinical chemistry laboratories in order to improve patient safety in pediatric health care. All clinical chemistry staff members were informed of the study and were requested to report in writing when a correction was made in the laboratory information system, Misys. Errors were detected either by the clinicians (the results did not fit the patients' clinical conditions) or by the laboratory technologists (the results were double-checked, and the worksheets were carefully examined twice a day). No incident that was discovered before or during the final validation was included. On each Monday of the study, we generated a report from Misys that listed all of the corrections made during the previous week. We then categorized the corrections according to the types and stages of the incidents that led to the corrections. A total of 187 incidents were detected during the 10-month study, representing a 0.26% error detection rate per requisition. The distribution of the detected incidents included 31 (17%) preanalytic incidents, 46 (25%) analytic incidents, and 110 (59%) postanalytic incidents. The errors related to noninterfaced tests accounted for 50% of the total incidents and for 37% of the affected tests and orderable panels, while the noninterfaced tests and panels accounted for 17% of the total test volume in our laboratory. This pilot study provided the rate and categories of errors detected in a pediatric clinical chemistry laboratory based on the corrections of results in the laboratory information system. A direct interface of the instruments to the laboratory information system showed that it had favorable effects on reducing laboratory errors.

  8. Target Detection Using an AOTF Hyperspectral Imager

    NASA Technical Reports Server (NTRS)

    Cheng, L-J.; Mahoney, J.; Reyes, F.; Suiter, H.

    1994-01-01

    This paper reports results of a recent field experiment using a prototype system to evaluate the acousto-optic tunable filter polarimetric hyperspectral imaging technology for target detection applications.

  9. Statistical Hypothesis Testing using CNN Features for Synthesis of Adversarial Counterexamples to Human and Object Detection Vision Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Raj, Sunny; Jha, Sumit Kumar; Pullum, Laura L.

    Validating the correctness of human detection vision systems is crucial for safety applications such as pedestrian collision avoidance in autonomous vehicles. The enormous space of possible inputs to such an intelligent system makes it difficult to design test cases for such systems. In this report, we present our tool MAYA that uses an error model derived from a convolutional neural network (CNN) to explore the space of images similar to a given input image, and then tests the correctness of a given human or object detection system on such perturbed images. We demonstrate the capability of our tool on themore » pre-trained Histogram-of-Oriented-Gradients (HOG) human detection algorithm implemented in the popular OpenCV toolset and the Caffe object detection system pre-trained on the ImageNet benchmark. Our tool may serve as a testing resource for the designers of intelligent human and object detection systems.« less

  10. Cost, weight and lead time impacts of a Mercedes-Benz 'Sensormat' type occupant detection system

    DOT National Transportation Integrated Search

    1997-04-19

    This summary report is based, in part, on the findings contained in Contract No. DTNH22-96-C-02063 entitled "Cost Analysis of the Mercedes-Benz Occupant Detection System for Air Bag Shut-Off" prepared by Ludtke and Associates of Washington, Michigan....

  11. Timeliness in the notification of spotted fever in Brazil: Evaluating compulsory reporting strategies and digital disease detection.

    PubMed

    de Oliveira, Stefan Vilges; Angerami, Rodrigo Nogueira

    2018-05-03

    Spotted fever caused by rickettsial species, the most important tick-borne disease. In Brazil, is nationwide communicable compulsory disease to the Ministry of Health. Since 2007, all suspected cases of spotted fever have been integrated into the Notifiable Diseases Information System (SINAN). In this descriptive study we evaluate the timeliness (expressed in number of days between time of clinical suspicion and reporting) of the compulsory notification of spotted fever cases in SINAN and the strategy for digital disease detection (DDD). It was analysed the information from the SINAN and from the digital detection strategy used by ProMED-Português. Results show that detection by the SINAN system was more efficient than Promed-Português, reporting 20.5 days earlier 90.4% of evaluated suspected cases. The surveillance strategy based on the mandatory case reporting using SINAN has proven to be more timely, but DDD can be considered as a complementary strategy providing a more disseminate epidemiological information to wide range readership globally. Copyright © 2018. Published by Elsevier Ltd.

  12. Detection of tunnel excavation using fiber optic reflectometry: experimental validation

    NASA Astrophysics Data System (ADS)

    Linker, Raphael; Klar, Assaf

    2013-06-01

    Cross-border smuggling tunnels enable unmonitored movement of people and goods, and pose a severe threat to homeland security. In recent years, we have been working on the development of a system based on fiber- optic Brillouin time domain reflectometry (BOTDR) for detecting tunnel excavation. In two previous SPIE publications we have reported the initial development of the system as well as its validation using small-scale experiments. This paper reports, for the first time, results of full-scale experiments and discusses the system performance. The results confirm that distributed measurement of strain profiles in fiber cables buried at shallow depth enable detection of tunnel excavation, and by proper data processing, these measurements enable precise localization of the tunnel, as well as reasonable estimation of its depth.

  13. Detection of Adverse Drug Reactions using Medical Named Entities on Twitter.

    PubMed

    MacKinlay, Andrew; Aamer, Hafsah; Yepes, Antonio Jimeno

    2017-01-01

    Adverse Drug Reactions (ADRs) are unintentional reactions caused by a drug or combination of drugs taken by a patient. The current ADR reporting systems inevitably have delays in reporting such events. The broad scope of social media conversations on sites such as Twitter means that inevitably health-related topics will be covered. This means that these sites could then be used to detect potentially novel ADRs with less latency for subsequent further investigation. In this work, we investigate ADR surveillance using a large corpus of Twitter data, containing around 50 billion tweets spanning 3 years (2012-2014), and evaluate against over 3000 drugs reported in the FAERS database. This is both a larger corpus and broader selection of drugs than previous work in the domain. We compare the ADRs identified using our method to the FDA Adverse Event Reporting System (FAERS) database of ADRs reported using more traditional techniques, and find that Twitter is a useful resource for ADR detection up to 72% micro-averaged precision. Micro-averaged recall of 6% is achievable using only 10% of Twitter, indicating that with a higher-volume or targeted feed it would be possible to detect a large percentage of ADRs.

  14. Flow-based analysis using microfluidics-chemiluminescence systems.

    PubMed

    Al Lawati, Haider A J

    2013-01-01

    This review will discuss various approaches and techniques in which analysis using microfluidics-chemiluminescence systems (MF-CL) has been reported. A variety of applications is examined, including environmental, pharmaceutical, biological, food and herbal analysis. Reported uses of CL reagents, sample introduction techniques, sample pretreatment methods, CL signal enhancement and detection systems are discussed. A hydrodynamic pumping system is predominately used for these applications. However, several reports are available in which electro-osmotic (EO) pumping has been implemented. Various sample pretreatment methods have been used, including liquid-liquid extraction, solid-phase extraction and molecularly imprinted polymers. A wide range of innovative techniques has been reported for CL signal enhancement. Most of these techniques are based on enhancement of the mixing process in the microfluidics channels, which leads to enhancement of the CL signal. However, other techniques are also reported, such as mirror reaction, liquid core waveguide, on-line pre-derivatization and the use of an opaque white chip with a thin transparent seal. Photodetectors are the most commonly used detectors; however, other detection systems have also been used, including integrated electrochemiluminescence (ECL) and organic photodiodes (OPDs). Copyright © 2012 John Wiley & Sons, Ltd.

  15. What are incident reports telling us? A comparative study at two Australian hospitals of medication errors identified at audit, detected by staff and reported to an incident system

    PubMed Central

    Westbrook, Johanna I.; Li, Ling; Lehnbom, Elin C.; Baysari, Melissa T.; Braithwaite, Jeffrey; Burke, Rosemary; Conn, Chris; Day, Richard O.

    2015-01-01

    Objectives To (i) compare medication errors identified at audit and observation with medication incident reports; (ii) identify differences between two hospitals in incident report frequency and medication error rates; (iii) identify prescribing error detection rates by staff. Design Audit of 3291patient records at two hospitals to identify prescribing errors and evidence of their detection by staff. Medication administration errors were identified from a direct observational study of 180 nurses administering 7451 medications. Severity of errors was classified. Those likely to lead to patient harm were categorized as ‘clinically important’. Setting Two major academic teaching hospitals in Sydney, Australia. Main Outcome Measures Rates of medication errors identified from audit and from direct observation were compared with reported medication incident reports. Results A total of 12 567 prescribing errors were identified at audit. Of these 1.2/1000 errors (95% CI: 0.6–1.8) had incident reports. Clinically important prescribing errors (n = 539) were detected by staff at a rate of 218.9/1000 (95% CI: 184.0–253.8), but only 13.0/1000 (95% CI: 3.4–22.5) were reported. 78.1% (n = 421) of clinically important prescribing errors were not detected. A total of 2043 drug administrations (27.4%; 95% CI: 26.4–28.4%) contained ≥1 errors; none had an incident report. Hospital A had a higher frequency of incident reports than Hospital B, but a lower rate of errors at audit. Conclusions Prescribing errors with the potential to cause harm frequently go undetected. Reported incidents do not reflect the profile of medication errors which occur in hospitals or the underlying rates. This demonstrates the inaccuracy of using incident frequency to compare patient risk or quality performance within or across hospitals. New approaches including data mining of electronic clinical information systems are required to support more effective medication error detection and mitigation. PMID:25583702

  16. Occurrence and distribution of methyl tert-butyl ether and other volatile organic compounds in drinking water in the Northeast and Mid-Atlantic regions of the United States, 1993-98

    USGS Publications Warehouse

    Grady, S.J.; Casey, G.D.

    2001-01-01

    Data on volatile organic compounds (VOCs) in drinking water supplied by 2,110 randomly selected community water systems (CWSs) in 12 Northeast and Mid-Atlantic States indicate 64 VOC analytes were detected at least once during 1993-98. Selection of the 2,110 CWSs inventoried for this study targeted 20 percent of the 10,479 active CWSs in the region and represented a random subset of the total distribution by State, source of water, and size of system. The data include 21,635 analyses of drinking water collected for compliance monitoring under the Safe Drinking Water Act; the data mostly represent finished drinking water collected at the pointof- entry to, or at more distal locations within, each CWS?s distribution system following any watertreatment processes. VOC detections were more common in drinking water supplied by large systems (serving more than 3,300 people) that tap surface-water sources or both surface- and groundwater sources than in small systems supplied exclusively by ground-water sources. Trihalomethane (THM) compounds, which are potentially formed during the process of disinfecting drinking water with chlorine, were detected in 45 percent of the randomly selected CWSs. Chloroform was the most frequently detected THM, reported in 39 percent of the CWSs. The gasoline additive methyl tert-butyl ether (MTBE) was the most frequently detected VOC in drinking water after the THMs. MTBE was detected in 8.9 percent of the 1,194 randomly selected CWSs that analyzed samples for MTBE at any reporting level, and it was detected in 7.8 percent of the 1,074 CWSs that provided MTBE data at the 1.0-?g/L (microgram per liter) reporting level. As with other VOCs reported in drinking water, most MTBE concentrations were less than 5.0 ?g/L, and less than 1 percent of CWSs reported MTBE concentrations at or above the 20.0-?g/L lower limit recommended by the U.S. Environmental Protection Agency?s Drinking-Water Advisory. The frequency of MTBE detections in drinking water is significantly related to high- MTBE-use patterns. Detections are five times more likely in areas where MTBE is or has been used in gasoline at greater than 5 percent by volume as part of the oxygenated or reformulated (OXY/RFG) fuels program. Detection frequencies of the individual gasoline compounds (benzene, toluene, ethylbenzene, and xylenes (BTEX)) were mostly less than 3 percent of the randomly selected CWSs, but collectively, BTEX compounds were detected in 8.4 percent of CWSs. BTEX concentrations also were low and just three drinkingwater samples contained BTEX at concentrations exceeding 20 ?g/L. Co-occurrence of MTBE and BTEX was rare, and only 0.8 percent of CWSs reported simultaneous detections of MTBE and BTEX compounds. Low concentrations and cooccurrence of MTBE and BTEX indicate most gasoline contaminants in drinking water probably represent nonpoint sources. Solvents were frequently detected in drinking water in the 12-State area. One or more of 27 individual solvent VOCs were detected at any reporting level in 3,080 drinking-water samples from 304 randomly selected CWSs (14 percent) and in 206 CWSs (9.8 percent) at concentrations at or above 1.0 ?g/L. High co-occurrence among solvents probably reflects common sources and the presence of transformation by-products. Other VOCs were relatively rarely detected in drinking water in the 12-State area. Six percent (127) of the 2,110 randomly selected CWSs reported concentrations of 16 VOCs at or above drinking-water criteria. The 127 CWSs collectively serve 2.6 million people. The occurrence of VOCs in drinking water was significantly associated (p<0.0001) with high population- density urban areas. New Jersey, Massachusetts, and Rhode Island, States with substantial urbanization and high population density, had the highest frequency of VOC detections among the 12 States. More than two-thirds of the randomly selected CWSs in New Jersey reported detecting VOC concentrations in drinking water at or above 1

  17. Report: Improvements Needed in EPA’s Network Traffic Management Practices

    EPA Pesticide Factsheets

    Report #11-P-0159, March 14, 2011. OEI does not have consistent, repeatable intrusion detection system monitoring practices in place, which inhibits EPA’s ability to monitor unusual network activity and thus protect Agency systems and associated data.

  18. Activity Tracking for Pilot Error Detection from Flight Data

    NASA Technical Reports Server (NTRS)

    Callantine, Todd J.; Ashford, Rose (Technical Monitor)

    2002-01-01

    This report presents an application of activity tracking for pilot error detection from flight data, and describes issues surrounding such an application. It first describes the Crew Activity Tracking System (CATS), in-flight data collected from the NASA Langley Boeing 757 Airborne Research Integrated Experiment System aircraft, and a model of B757 flight crew activities. It then presents an example of CATS detecting actual in-flight crew errors.

  19. Director, Operational Test and Evaluation FY 2004 Annual Report

    DTIC Science & Technology

    2004-01-01

    HIGH) Space Based Radar (SBR) Sensor Fuzed Weapon (SFW) P3I (CBU-97/B) Small Diameter Bomb (SDB) Secure Mobile Anti-Jam Reliable Tactical Terminal...detection, identification, and sampling capability for both fixed-site and mobile operations. The system must automatically detect and identify up to ten...staffing within the Services. SYSTEM DESCRIPTION AND MISSION The Services envision JCAD as a hand-held device that automatically detects, identifies, and

  20. State-of-the-art technologies for intrusion and obstacle detection for railroad operations

    DOT National Transportation Integrated Search

    2007-07-01

    This report provides an update on the state-of-the-art technologies with intrusion and obstacle detection capabilities for rail rights of way (ROW) and crossings. A workshop entitled Intruder and Obstacle Detection Systems (IODS) for Railroads Requir...

  1. Exploration of the association rules mining technique for the signal detection of adverse drug events in spontaneous reporting systems.

    PubMed

    Wang, Chao; Guo, Xiao-Jing; Xu, Jin-Fang; Wu, Cheng; Sun, Ya-Lin; Ye, Xiao-Fei; Qian, Wei; Ma, Xiu-Qiang; Du, Wen-Min; He, Jia

    2012-01-01

    The detection of signals of adverse drug events (ADEs) has increased because of the use of data mining algorithms in spontaneous reporting systems (SRSs). However, different data mining algorithms have different traits and conditions for application. The objective of our study was to explore the application of association rule (AR) mining in ADE signal detection and to compare its performance with that of other algorithms. Monte Carlo simulation was applied to generate drug-ADE reports randomly according to the characteristics of SRS datasets. Thousand simulated datasets were mined by AR and other algorithms. On average, 108,337 reports were generated by the Monte Carlo simulation. Based on the predefined criterion that 10% of the drug-ADE combinations were true signals, with RR equaling to 10, 4.9, 1.5, and 1.2, AR detected, on average, 284 suspected associations with a minimum support of 3 and a minimum lift of 1.2. The area under the receiver operating characteristic (ROC) curve of the AR was 0.788, which was equivalent to that shown for other algorithms. Additionally, AR was applied to reports submitted to the Shanghai SRS in 2009. Five hundred seventy combinations were detected using AR from 24,297 SRS reports, and they were compared with recognized ADEs identified by clinical experts and various other sources. AR appears to be an effective method for ADE signal detection, both in simulated and real SRS datasets. The limitations of this method exposed in our study, i.e., a non-uniform thresholds setting and redundant rules, require further research.

  2. Automatic detection of pulmonary nodules at spiral CT: first clinical experience with a computer-aided diagnosis system

    NASA Astrophysics Data System (ADS)

    Wormanns, Dag; Fiebich, Martin; Wietholt, Christian; Diederich, Stefan; Heindel, Walter

    2000-06-01

    We evaluated the practical application of a Computer-Aided Diagnosis (CAD) system for viewing spiral computed tomography (CT) of the chest low-dose screening examinations which includes an automatic detection of pulmonary nodules. A UNIX- based CAD system was developed including a detection algorithm for pulmonary nodules and a user interface providing an original axial image, the same image with nodules highlighted, a thin-slab MIP, and a cine mode. As yet, 26 CT examinations with 1625 images were reviewed in a clinical setting and reported by an experienced radiologist using both the CAD system and hardcopies. The CT studies exhibited 19 nodules found on the hardcopies in consensus reporting of 2 experienced radiologists. Viewing with the CAD system was more time consuming than using hardcopies (4.16 vs. 2.92 min) due to analyzing MIP and cine mode. The algorithm detected 49% (18/37) pulmonary nodules larger than 5 mm and 30% (21/70) of all nodules. It produced an average of 6.3 false positive findings per CT study. Most of the missed nodules were adjacent to the pleura. However, the program detected 6 nodules missed by the radiologists. Automatic nodule detection increases the radiologists's awareness of pulmonary lesions. Simultaneous display of axial image and thin-slab MIP makes the radiologist more confident in diagnosis of smaller pulmonary nodules. The CAD system improves the detection of pulmonary nodules at spiral CT. Lack of sensitivity and specificity is still an issue to be addressed but does not prevent practical use.

  3. Detecting Lyme disease using antibody-functionalized carbon nanotubes

    NASA Astrophysics Data System (ADS)

    Dailey, Jennifer; Lerner, Mitchell; Goldsmith, Brett; Brisson, Dustin; Johnson, A. T. Charlie

    2011-03-01

    We combine antibodies for Lyme flagellar protein with carbon nanotube transistors to create an electronic sensor capable of definitive detection of Lyme disease. Over 35,000 cases of Lyme disease are reported in the United States each year, of which more than 23 percent are originally misdiagnosed. Rational design of the coupling of the biological system to the electronic system gives us a flexible sensor platform which we can apply to several biological systems. By coupling these antibodies to carbon nanotubes in particular, we allow for fast, sensitive, highly selective, electronic detection. Unlike antibody or biomarker detection, bacterial protein detection leads to positive identification of both early and late stage bacterial infections, and is easily expandable to environmental monitoring.

  4. The simulation study on optical target laser active detection performance

    NASA Astrophysics Data System (ADS)

    Li, Ying-chun; Hou, Zhao-fei; Fan, Youchen

    2014-12-01

    According to the working principle of laser active detection system, the paper establishes the optical target laser active detection simulation system, carry out the simulation study on the detection process and detection performance of the system. For instance, the performance model such as the laser emitting, the laser propagation in the atmosphere, the reflection of optical target, the receiver detection system, the signal processing and recognition. We focus on the analysis and modeling the relationship between the laser emitting angle and defocus amount and "cat eye" effect echo laser in the reflection of optical target. Further, in the paper some performance index such as operating range, SNR and the probability of the system have been simulated. The parameters including laser emitting parameters, the reflection of the optical target and the laser propagation in the atmosphere which make a great influence on the performance of the optical target laser active detection system. Finally, using the object-oriented software design methods, the laser active detection system with the opening type, complete function and operating platform, realizes the process simulation that the detection system detect and recognize the optical target, complete the performance simulation of each subsystem, and generate the data report and the graph. It can make the laser active detection system performance models more intuitive because of the visible simulation process. The simulation data obtained from the system provide a reference to adjust the structure of the system parameters. And it provides theoretical and technical support for the top level design of the optical target laser active detection system and performance index optimization.

  5. Performance analysis of a multispectral system for mine detection in the littoral zone

    NASA Astrophysics Data System (ADS)

    Hargrove, John T.; Louchard, Eric

    2004-09-01

    Science & Technology International (STI) has developed, under contract with the Office of Naval Research, a system of multispectral airborne sensors and processing algorithms capable of detecting mine-like objects in the surf zone. STI has used this system to detect mine-like objects in a littoral environment as part of blind tests at Kaneohe Marine Corps Base Hawaii, and Panama City, Florida. The airborne and ground subsystems are described. The detection algorithm is graphically illustrated. We report on the performance of the system configured to operate without a human in the loop. A subsurface (underwater bottom proud mine in the surf zone and moored mine in shallow water) mine detection capability is demonstrated in the surf zone, and in shallow water with wave spillage and foam. Our analysis demonstrates that this STI-developed multispectral airborne mine detection system provides a technical foundation for a viable mine counter-measures system for use prior to an amphibious assault.

  6. Advanced Clinical Decision Support for Vaccine Adverse Event Detection and Reporting.

    PubMed

    Baker, Meghan A; Kaelber, David C; Bar-Shain, David S; Moro, Pedro L; Zambarano, Bob; Mazza, Megan; Garcia, Crystal; Henry, Adam; Platt, Richard; Klompas, Michael

    2015-09-15

    Reporting of adverse events (AEs) following vaccination can help identify rare or unexpected complications of immunizations and aid in characterizing potential vaccine safety signals. We developed an open-source, generalizable clinical decision support system called Electronic Support for Public Health-Vaccine Adverse Event Reporting System (ESP-VAERS) to assist clinicians with AE detection and reporting. ESP-VAERS monitors patients' electronic health records for new diagnoses, changes in laboratory values, and new allergies following vaccinations. When suggestive events are found, ESP-VAERS sends the patient's clinician a secure electronic message with an invitation to affirm or refute the message, add comments, and submit an automated, prepopulated electronic report to VAERS. High-probability AEs are reported automatically if the clinician does not respond. We implemented ESP-VAERS in December 2012 throughout the MetroHealth System, an integrated healthcare system in Ohio. We queried the VAERS database to determine MetroHealth's baseline reporting rates from January 2009 to March 2012 and then assessed changes in reporting rates with ESP-VAERS. In the 8 months following implementation, 91 622 vaccinations were given. ESP-VAERS sent 1385 messages to responsible clinicians describing potential AEs. Clinicians opened 1304 (94.2%) messages, responded to 209 (15.1%), and confirmed 16 for transmission to VAERS. An additional 16 high-probability AEs were sent automatically. Reported events included seizure, pleural effusion, and lymphocytopenia. The odds of a VAERS report submission during the implementation period were 30.2 (95% confidence interval, 9.52-95.5) times greater than the odds during the comparable preimplementation period. An open-source, electronic health record-based clinical decision support system can increase AE detection and reporting rates in VAERS. © The Author 2015. Published by Oxford University Press on behalf of the Infectious Diseases Society of America. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  7. Evaluation of roadside emergency call box technology : a summary report : technical assistance report.

    DOT National Transportation Integrated Search

    2003-04-01

    Introduction Motorist aid call boxes are used to provide motorist assistance, improve safety, and can serve as an incident detection tool. More recently, Intelligent Transportation Systems (ITS) applications have been added to call box systems to enh...

  8. Conference Report: Biosignature Preservation and Detection in Mars Analog Environments.

    PubMed

    Hays, Lindsay; Beaty, David

    2017-01-01

    The Conference on Biosignature Preservation and Detection in Mars Analog Environments held in May 2016 brought together scientists to discuss microbial biosignatures in Mars analog habitable environments. Five analog environments were discussed: (1) hydrothermal spring systems, (2) subaqueous environments, (3) subaerial environments, (4) subsurface environments, and (5) iron-rich systems. This paper details the major messages that resulted from the discussions and will be followed by a review paper that adds significant detail from the published literature and interpretations from the writing committee of the workshop for future research and application to astrobiological exploration missions. Key Words: Biosignature preservation-Biosignature detection-Mars analog environments-Conference report-Astrobiological exploration. Astrobiology 17, 1-2.

  9. Optically Based Flame Detection in the NASA Langley 8-ft High- Temperature Wind Tunnel

    NASA Technical Reports Server (NTRS)

    Borg, Stephen E.

    2005-01-01

    Two optically based flame-detection systems have been developed for use in NASA Langley's 8-Foot High-Temperature Tunnel (8-ft HTT). These systems are used to detect the presence and stability of the main-burner and pilot-level flames during facility operation. System design considerations will be discussed, and a detailed description of the system components and circuit diagrams will be provided in the Appendices of this report. A more detailed description of the manufacturing process used in the fabrication of the fiber-optic probes is covered in NASA TM-2001-211233.

  10. Application of DNA Aptamers and Quantum Dots to Lateral Flow Test Strips for Detection of Foodborne Pathogens with Improved Sensitivity versus Colloidal Gold

    PubMed Central

    Bruno, John G.

    2014-01-01

    Preliminary studies aimed at improving the sensitivity of foodborne pathogen detection via lateral flow (LF) test strips by use of high affinity DNA aptamers for capture and reporter functions when coupled to red-emitting quantum dots (Qdot 655) are reported. A variety of DNA aptamers developed against Escherichia coli, Listeria monocytogenes, and Salmonella enterica were paired in capture and reporter combinations to determine which yielded the strongest detection of their cognate bacteria using a colloidal gold screening system. Several promising sandwich combinations were identified for each of the three bacterial LF strip systems. The best E. coli aptamer-LF system was further studied and yielded a visible limit of detection (LOD) of ~3,000 E. coli 8739 and ~6,000 E. coli O157:H7 in buffer. These LODs were reduced to ~300–600 bacterial cells per test respectively by switching to a Qdot 655 aptamer-LF system. Novel aspects of these assays such as the use of high levels of detergents to avoid quantum dot agglutination and enhance migration in analytical membranes, identification of optimal analytical membrane types, UV-immobilization of capture aptamers, and novel dual biotin/digoxigenin-end labeled aptamer streptavidin-colloidal gold or -Qdot 655 conjugates plus anti-digoxigenin antibody control lines are also discussed. In general, this work provides proof-of-principle for highly sensitive aptamer-Qdot LF strip assays for rapid foodborne pathogen detection. PMID:25437803

  11. ETV Report and Statement for ENDETEC TECTA™ B-16 BY PATHOGEN DETECTION SYSTEMS, INC.

    EPA Science Inventory

    This report provides results for the verification testing of the ENDETEC™ TECTA B-16 by PDS (hereafter referred to as the TECTA™ B-16). The following is a description of the TECTA B-16, based on information provided by the vendor. The TECTA B-16 is a bench top detection and data ...

  12. 12 CFR 222.90 - Duties regarding the detection, prevention, and mitigation of identity theft.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... mitigation of identity theft. 222.90 Section 222.90 Banks and Banking FEDERAL RESERVE SYSTEM (CONTINUED) BOARD OF GOVERNORS OF THE FEDERAL RESERVE SYSTEM FAIR CREDIT REPORTING (REGULATION V) Identity Theft Red Flags § 222.90 Duties regarding the detection, prevention, and mitigation of identity theft. (a) Scope...

  13. 12 CFR 222.90 - Duties regarding the detection, prevention, and mitigation of identity theft.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... mitigation of identity theft. 222.90 Section 222.90 Banks and Banking FEDERAL RESERVE SYSTEM (CONTINUED) BOARD OF GOVERNORS OF THE FEDERAL RESERVE SYSTEM FAIR CREDIT REPORTING (REGULATION V) Identity Theft Red Flags § 222.90 Duties regarding the detection, prevention, and mitigation of identity theft. (a) Scope...

  14. Potential effect of CAD systems on the detection of actionable nodules in chest CT scans during routine reporting

    NASA Astrophysics Data System (ADS)

    Wormanns, Dag; Beyer, Florian; Butzbach, Arnauld; Zierott, Livia; Heindel, Walter

    2006-03-01

    The purpose of the presented study was to determine the impact of two different CAD systems used as concur-rent reader for detection of actionable nodules (>4 mm) on the interpretation of chest CT scans during routine reporting. Fifty consecutive MDCT scans (1 mm or 1.25 mm slice thickness, 0.8 mm reconstruction increment) were se-lected from clinical routine. All cases were read by a resident and a staff radiologist, and a written report was available in the radiology information system (RIS). The RIS report mentioned at least one actionable pulmonary nodule in 18 cases (50%) and did not report any pulmonary nodule in the remaining 32 cases. Two different recent CAD systems were independently applied to the 50 CT scans as concurrent reader with two radiologists: Siemens LungCare NEV and MEDIAN CAD-Lung. Two radiologists independently reviewed the CAD results and determined if a CAD result was a true positive or a false positive finding. Patients were classified into two groups: in group A if at least one actionable nodule was detected and in group B if no actionable nodules were found. The effect of CAD on routine reporting was simulated as set union of the findings of routine reporting and CAD thus applying CAD as concurrent reader. According to the RIS report group A (patients with at least one actionable nodule) contained 18 cases (36% of all 50 cases), and group B contained 32 cases. Application of a CAD system as concurrent reader resulted in detec-tion of additional CT scans with actionable nodules and reclassification into group A in 16 resp. 18 cases (radi-ologist 1 resp. radiologist 2) with Siemens NEV and in 19 resp. 18 cases with MEDIAN CAD-Lung. In seven cases MEDIAN CAD-Lung and in four cases Siemens NEV reclassified a case into group A while the other CAD system missed the relevant finding. Sensitivity on a nodule (>4 mm) base was .45 for Siemens NEV and .55 for MEDIAN CAD-Lung; the difference was not yet significant (p=.077). In our study use of CAD as second reader in routine reporting doubled the percentage of patients with actionable nodules larger than 4 mm.

  15. Application of thermoluminescence for detection of cascade shower 1: Hardware and software of reader system

    NASA Technical Reports Server (NTRS)

    Akashi, M.; Kawaguchi, S.; Watanabe, Z.; Misaki, A.; Niwa, M.; Okamoto, Y.; Fujinaga, T.; Ichimura, M.; Shibata, T.; Dake, S.

    1985-01-01

    A reader system for the detection of cascade showers via luminescence induced by heating sensitive material (BaSO4:Eu) is developed. The reader system is composed of following six instruments: (1) heater, (2) light guide, (3) image intensifier, (4) CCD camera, (5) image processor, (6) microcomputer. The efficiency of these apparatuses and software application for image analysis is reported.

  16. Management system of occupational diseases in Korea: statistics, report and monitoring system.

    PubMed

    Rhee, Kyung Yong; Choe, Seong Weon

    2010-12-01

    The management system of occupational diseases in Korea can be assessed from the perspective of a surveillance system. Workers' compensation insurance reports are used to produce official statistics on occupational diseases in Korea. National working conditions surveys are used to monitor the magnitude of work-related symptoms and signs in the labor force. A health examination program was introduced to detect occupational diseases through both selective and mass screening programs. The Working Environment Measurement Institution assesses workers' exposure to hazards in the workplace. Government regulates that the employer should do health examinations and working conditions measurement through contracted private agencies and following the Occupational Safety and Health Act. It is hoped that these institutions may be able to effectively detect and monitor occupational diseases and hazards in the workplace. In view of this, the occupational management system in Korea is well designed, except for the national survey system. In the future, national surveys for detection of hazards and ill-health outcomes in workers should be developed. The existing surveillance system for occupational disease can be improved by providing more refined information through statistical analysis of surveillance data.

  17. Joint Improved Explosive Device Defeat Organization. Annual Report FY 2009

    DTIC Science & Technology

    2009-01-01

    incident, IEDs were 14 percent more effective in FY 2009 over FY 2008. Coupled with the significant corresponding increase in IED incidents, this...Testing and Evaluation (RDT&E), procurement, and sustainment of 69 systems. Detect Air Detect Air systems enable the warfighter to detect insurgent...oriented centers of excellence (COE): the Army COE at Fort Irwin; the Navy COE at Indian Head, Maryland; the Air Force COE at Lackland Air Force

  18. Real-time reporting of baleen whale passive acoustic detections from ocean gliders.

    PubMed

    Baumgartner, Mark F; Fratantoni, David M; Hurst, Thomas P; Brown, Moira W; Cole, Tim V N; Van Parijs, Sofie M; Johnson, Mark

    2013-09-01

    In the past decade, much progress has been made in real-time passive acoustic monitoring of marine mammal occurrence and distribution from autonomous platforms (e.g., gliders, floats, buoys), but current systems focus primarily on a single call type produced by a single species, often from a single location. A hardware and software system was developed to detect, classify, and report 14 call types produced by 4 species of baleen whales in real time from ocean gliders. During a 3-week deployment in the central Gulf of Maine in late November and early December 2012, two gliders reported over 25,000 acoustic detections attributed to fin, humpback, sei, and right whales. The overall false detection rate for individual calls was 14%, and for right, humpback, and fin whales, false predictions of occurrence during 15-min reporting periods were 5% or less. Transmitted pitch tracks--compact representations of sounds--allowed unambiguous identification of both humpback and fin whale song. Of the ten cases when whales were sighted during aerial or shipboard surveys and a glider was within 20 km of the sighting location, nine were accompanied by real-time acoustic detections of the same species by the glider within ±12 h of the sighting time.

  19. Towards detection of pipeline integrity threats using a smart fiber optic surveillance system: PIT-STOP project blind field test results

    NASA Astrophysics Data System (ADS)

    Tejedor, J.; Macias-Guarasa, J.; Martins, H. F.; Piote, D.; Pastor-Graells, J.; Martin-Lopez, S.; Corredera, P.; De Pauw, G.; De Smet, F.; Postvoll, W.; Ahlen, C. H.; Gonzalez-Herraez, M.

    2017-04-01

    This paper presents the first report on on-line and final blind field test results of a pipeline integrity threat surveillance system. The system integrates a machine+activity identification mode, and a threat detection mode. Two different pipeline sections were selected for the blind tests: One close to the sensor position, and the other 35 km away from it. Results of the machine+activity identification mode showed that about 46% of the times the machine, the activity or both were correctly identified. For the threat detection mode, 8 out of 10 threats were correctly detected, with 1 false alarm.

  20. A miniaturised image based fluorescence detection system for point-of-care-testing of cocaine abuse

    NASA Astrophysics Data System (ADS)

    Walczak, Rafał; Krüger, Jan; Moynihan, Shane

    2015-08-01

    In this paper, we describe a miniaturised image-based fluorescence detection system and demonstrate its viability as a highly sensitive tool for point-of-care-analysis of drugs of abuse in human sweat with a focus on monitor individuals for drugs of abuse. Investigations of miniaturised and low power optoelectronic configurations and methodologies for real-time image analysis were successfully carried out. The miniaturised fluorescence detection system was validated against a reference detection system under controlled laboratory conditions by analysing spiked sweat samples in dip stick and then strip with sample pad. As a result of the validation studies, a 1 ng mL-1 limit of detection of cocaine in sweat and full agreement of test results with the reference detection system can be reported. Results of the investigations open the way towards a detection system that integrates a hand-held fluorescence reader and a wearable skinpatch, and which can collect and in situ analyse sweat for the presence of cocaine at any point for up to tenths hours.

  1. TED: a novel man portable infrared detection and situation awareness system

    NASA Astrophysics Data System (ADS)

    Tidhar, Gil; Manor, Ran

    2007-04-01

    Infrared Search and Track (IRST) and threat warning systems are used in vehicle mounted or in fixed land positions. Migration of this technology to the man portable applications proves to be difficult due to the tight constraints of power consumption, dimensions, weight and due to the high video rate requirements. In this report we provide design details of a novel transient event detection (TED) system, capable of detection of blasts and gun shot events in a very wide field of view, while used by an operator in motion

  2. A signal detection method for temporal variation of adverse effect with vaccine adverse event reporting system data.

    PubMed

    Cai, Yi; Du, Jingcheng; Huang, Jing; Ellenberg, Susan S; Hennessy, Sean; Tao, Cui; Chen, Yong

    2017-07-05

    To identify safety signals by manual review of individual report in large surveillance databases is time consuming; such an approach is very unlikely to reveal complex relationships between medications and adverse events. Since the late 1990s, efforts have been made to develop data mining tools to systematically and automatically search for safety signals in surveillance databases. Influenza vaccines present special challenges to safety surveillance because the vaccine changes every year in response to the influenza strains predicted to be prevalent that year. Therefore, it may be expected that reporting rates of adverse events following flu vaccines (number of reports for a specific vaccine-event combination/number of reports for all vaccine-event combinations) may vary substantially across reporting years. Current surveillance methods seldom consider these variations in signal detection, and reports from different years are typically collapsed together to conduct safety analyses. However, merging reports from different years ignores the potential heterogeneity of reporting rates across years and may miss important safety signals. Reports of adverse events between years 1990 to 2013 were extracted from the Vaccine Adverse Event Reporting System (VAERS) database and formatted into a three-dimensional data array with types of vaccine, groups of adverse events and reporting time as the three dimensions. We propose a random effects model to test the heterogeneity of reporting rates for a given vaccine-event combination across reporting years. The proposed method provides a rigorous statistical procedure to detect differences of reporting rates among years. We also introduce a new visualization tool to summarize the result of the proposed method when applied to multiple vaccine-adverse event combinations. We applied the proposed method to detect safety signals of FLU3, an influenza vaccine containing three flu strains, in the VAERS database. We showed that it had high statistical power to detect the variation in reporting rates across years. The identified vaccine-event combinations with significant different reporting rates over years suggested potential safety issues due to changes in vaccines which require further investigation. We developed a statistical model to detect safety signals arising from heterogeneity of reporting rates of a given vaccine-event combinations across reporting years. This method detects variation in reporting rates over years with high power. The temporal trend of reporting rate across years may reveal the impact of vaccine update on occurrence of adverse events and provide evidence for further investigations.

  3. Development and Evaluation of a Diagnostic Documentation Support System using Knowledge Processing

    NASA Astrophysics Data System (ADS)

    Makino, Kyoko; Hayakawa, Rumi; Terai, Koichi; Fukatsu, Hiroshi

    In this paper, we will introduce a system which supports creating diagnostic reports. Diagnostic reports are documents by doctors of radiology describing the existence and nonexistence of abnormalities from the inspection images, such as CT and MRI, and summarize a patient's state and disease. Our system indicates insufficiencies in these reports created by younger doctors, by using knowledge processing based on a medical knowledge dictionary. These indications are not only clerical errors, but the system also analyzes the purpose of the inspection and determines whether a comparison with a former inspection is required, or whether there is any shortage in description. We verified our system by using actual data of 2,233 report pairs, a pair comprised of a report written by a younger doctor and a check result of the report by an experienced doctor. The results of the verification showed that the rules of string analysis for detecting clerical errors and sentence wordiness obtained a recall of over 90% and a precision of over 75%. Moreover, the rules based on a medical knowledge dictionary for detecting the lack of required comparison with a former inspection and the shortage in description for the inspection purpose obtained a recall of over 70%. From these results, we confirmed that our system contributes to the quality improvement of diagnostic reports. We expect that our system can comprehensively support diagnostic documentations by cooperating with the interface which refers to inspection images or past reports.

  4. Staphylococcus aureus detection in blood samples by silica nanoparticle-oligonucleotides conjugates.

    PubMed

    Borsa, Baris A; Tuna, Bilge G; Hernandez, Frank J; Hernandez, Luiza I; Bayramoglu, Gulay; Arica, M Yakup; Ozalp, V Cengiz

    2016-12-15

    A fast, specific and sensitive homogeneous assay for Staphylococcus aureus detection was developed by measuring the activity of secreted nuclease from the bacteria via a modified DNA oligonucleotide. As biosensor format, an effective system, Nanokeepers as previously reported, were used for triggered release of confined fluorophores, and hence specific detection of S. aureus on nuclease activity was obtained. The interference from blood components for fluorescent quantification was eliminated by a pre-purification by aptamer-functionalized silica magnetic nanoparticles. The reported assay system was exclusively formed by nucleic acid oligos and magnetic or mesoporous silica nanoparticles, that can be used on blood samples in a stepwise manner. The assay was successfully used as a sensing platform for the specific detection of S. aureus cells as low as 682 CFU in whole blood. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. A self-assembled fluorescent organic nanoprobe and its application for sulfite detection in food samples and living systems.

    PubMed

    Gao, Tang; Cao, Xiaozheng; Ge, Peng; Dong, Jie; Yang, Shuqi; Xu, Huan; Wu, Yong; Gao, Feng; Zeng, Wenbin

    2017-05-23

    Sulfur dioxide (SO 2 ) is a widely distributed air pollutant, and humans can easily be exposed to sulfite by inhaling SO 2 , thus inducing respiratory responses and diseases. Hence, to develop a rapid, sensitive and selective method for detection of sulfites is of great importance. Herein, we designed and synthesized a novel tetraphenyl imidazole compound TIBM with aggregation-induced emission enhancement (AIEE). TIBM can self-assemble into well-organized nanoparticles and is reported as an excellent probe for detection of sulfite with high selectivity and sensitivity. The nanoprobe performed very well for the detection of sulfite with an ultrafast detection time (15 s) and an ultralow detection limit (7.4 nM), which is superior to most of the reported probes. Moreover, the nanoprobe was successfully used to detect sulfite in food samples with a favorable accuracy. In addition, we developed paper-based devices for point-of-care detection of sulfite with naked eyes. Furthermore, due to its high water solubility, cell membrane permeability and good biocompatibility, the nanoproboe was further applied to detect sulfite in living systems. This study may offer some helpful insights for designing other AIE-based fluorescent nanosensors for various analytes.

  6. Bilaterally obstructed ureteropelvic junction of the upper moieties in a complete duplex collecting system.

    PubMed

    Latayan, Michael Jonathan R; Dator, Jose Dante P; Torres, Carlos Ramon N

    2008-02-01

    Maternal ultrasound is a routine examination in prenatal evaluation. The number of fetal abnormalities detected has been increasing, and includes fetal hydronephrosis which is secondary to ureteropelvic junction obstruction in 80% of cases. We report a case of a 1-year-old female infant with hydronephrosis prenatally detected by ultrasound. After close postnatal follow-up and diagnosis, she eventually underwent a definitive reconstructive procedure. This is the first reported case of a bilateral ureteropelvic junction obstruction of the upper moieties of a duplex collecting system.

  7. Towards a Cyber Defense Framework for SCADA Systems Based on Power Consumption Monitoring

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hernandez Jimenez, Jarilyn M; Chen, Qian; Nichols, Jeff A.

    Supervisory control and data acquisition (SCADA) is an industrial automation system that remotely monitor, and control critical infrastructures. SCADA systems are major targets for espionage and sabotage attackers. According to the 2015 Dell security annual threat report, the number of cyber-attacks against SCADA systems has doubled in the past year. Cyber-attacks (i.e., buffer overflow, rootkits and code injection) could cause serious financial losses and physical infrastructure damages. Moreover, some specific cyber-attacks against SCADA systems could become a threat to human life. Current commercial off-the-shelf security solutions are insufficient in protecting SCADA systems against sophisticated cyber-attacks. In 2014 a report bymore » Mandiant stated that only 69% of organizations learned about their breaches from third entities, meaning that these companies lack of their own detection system. Furthermore, these breaches are not detected in real-time or fast enough to prevent further damages. The average time between compromise and detection (for those intrusions that were detected) was 205 days. To address this challenge, we propose an Intrusion Detection System (IDS) that detects SCADA-specific cyber-attacks by analyzing the power consumption of a SCADA device. Specifically, to validate the proposed approach, we chose to monitor in real-time the power usage of a a Programmable Logic Controller (PLC). To this end, we configured the hardware of the tetsbed by installing the required sensors to monitor and collect its power consumption. After that two SCADA-specific cyber-attacks were simulated and TracerDAQ Pro was used to collect the power consumption of the PLC under normal and anomalous scenarios. Results showed that is possible to distinguish between the regular power usage of the PLC and when the PLC was under specific cyber-attacks.« less

  8. Postoperative Surgical Site Infections: Understanding the Discordance Between Surveillance Systems.

    PubMed

    Ali-Mucheru, Mariam N; Seville, Maria T; Miller, Vickie; Sampathkumar, Priya; Etzioni, David A

    2018-04-18

    To characterize agreement in the ascertainment of surgical site infections (SSIs) between the National Surgical Quality Improvement Program (NSQIP), National Healthcare Safety Network (NHSN), and administrative data. The NSQIP, NHSN, and administrative data are the primary systems used to monitor and report SSIs for the purpose of quality control and benchmarking of hospitals and surgeons. These systems have different methods for identifying SSIs. We queried the NHSN, NSQIP, and administrative data systems for patients who had an operation at 1 of 4 hospitals within a single health system between January 2013 and September 2015. The detection of an SSI during a postoperative hospitalization was the outcome of analysis. Any SSI detected by one (or more) of these systems was analyzed by 2 reviewers to determine the presence of discrete elements of documentation constituting evidence of SSI. Concordance between the 3 systems (NHSN, NSQIP, and administrative data) was analyzed using Cohen's kappa. After application of appropriate exclusion criteria, a cohort of 9447 inpatient operations was analyzed. In total, 130 SSIs were detected by 1 or more of the 3 systems, with reported SSI rates of 0.5% (NHSN), 0.7% (administrative data), and 1.0% (NSQIP). Of these 130 SSIs, only 17 SSIs were reported by all 3 systems. The concordance between these 3 systems was moderate (kappa values NSQIP-NHSN = 0.50 [0.40-0.60], administrative-NHSN = 0.36 [0.24-0.47], and administrative-NSQIP = 0.47 [0.38-0.57]). Chart review found that reasons for discordance were related to issues of different criteria as well as inaccuracies. There is significant discordance in the determination of SSIs reported by the NHSN, NSQIP, and administrative data. The differences and limitations of each of these systems have to be recognized, especially when using these data for quality reports and pay for performance.

  9. Cancer Imaging: Gene Transcription-Based Imaging and Therapeutic Systems

    PubMed Central

    Bhang, Hyo-eun C.; Pomper, Martin G.

    2012-01-01

    Molecular-genetic imaging of cancer is in its infancy. Over the past decade gene reporter systems have been optimized in preclinical models and some have found their way into the clinic. The search is on to find the best combination of gene delivery vehicle and reporter imaging system that can be translated safely and quickly. The goal is to have a combination that can detect a wide variety of cancers with high sensitivity and specificity in a way that rivals the current clinical standard, positron emission tomography with [18F]fluorodeoxyglucose. To do so will require systemic delivery of reporter genes for the detection of micrometastases, and a nontoxic vector, whether viral or based on nanotechnology, to gain widespread acceptance by the oncology community. Merger of molecular-genetic imaging with gene therapy, a strategy that has been employed in the past, will likely be necessary for such imaging to reach widespread clinical use. PMID:22349219

  10. DESI-Detection of early-season invasives (software-installation manual and user's guide version 1.0)

    USGS Publications Warehouse

    Kokaly, Raymond F.

    2011-01-01

    This report describes a software system for detecting early-season invasive plant species, such as cheatgrass. The report includes instructions for installing the software and serves as a user's guide in processing Landsat satellite remote sensing data to map the distributions of cheatgrass and other early-season invasive plants. The software was developed for application to the semi-arid regions of southern Utah; however, the detection parameters can be altered by the user for application to other areas.

  11. Matched Filtering of Visual Evoked Potentials to Detect Acceleration (+Gz) Induced Blackout

    DTIC Science & Technology

    1985-01-03

    FILTERING OF VISUAL EVOKED POTENTIALS rO DETECT ACCELERATION ( + Gz) INDUCED BLACKOUT John Q. Nelson, Leonid Hrebien and Joseph P. Cammarota Aircraft...8217: , r .,.V -. 1-». .v. IE •> _"->.-"*« A^V :j% _"«;_"V X~«. _~»^"V.i.~» iuTtuTii i."»..-^. .-*._> r /; NOTICES REPORT NUMBERING SYSTEM - The...Potentials to Detect Acceleration (+G2) Induced Blackout 12 PERSONAL AUTHOR(S) John G. Nelson, Leonid Hrebien, Joseph P. Cammarota 13* TYPE OF REPORT

  12. ITS Architecture Development Program, Phase I; Summary Report

    DOT National Transportation Integrated Search

    1994-11-01

    IN-VEHICLE EMISSIONS DIAGNOSIS, COMMERCIAL VEHICLES OPERATIONS OR CVO, ADVANCED VEHICLE CONTROL AND SAFETY SYSTEMS OR AVCSS, ADVANCED PUBLIC TRANSPORTATION SYSTEMS OR APTS, INCIDENT MANAGEMENT/INCIDENT DETECTION, COLLISION AVOIDANCE SYSTEM, AUTOMATED...

  13. A Resonant Synchronous Vibration Based Approach for Rotor Imbalance Detection

    NASA Technical Reports Server (NTRS)

    Luo, Huangeng; Rodriquez, Hector; Hallman, Darren; Lewicki, David G.

    2006-01-01

    This paper presents a methodology of detecting rotor imbalances, such as mass imbalance and crack-induced imbalance, using shaft synchronous vibrations. An iterative scheme is developed to identify parameters from measured synchronous vibration data. A detection system is integrated by using state-of-the-art commercial analysis equipment. A laboratory rotor test rig is used to verify the system integration and algorithm validation. A real engine test has been carried out and the results are reported.

  14. Ground Wind Vortex Sensing System Calibration Tests

    DOT National Transportation Integrated Search

    1980-02-01

    This report describes the collection of data related to the calibration of two systems for detecting and tracking aircraft wake vortices. The systems tested were the propeller anemometer Ground Wind Vortex Sensing System and the Pulsed Acoustic Vorte...

  15. Detection technology for IVHS : Volume I: Final Report

    DOT National Transportation Integrated Search

    1996-12-01

    The Detection Technology for the IVHS project identified traffic parameters and their required accuracies for characterizing traffic flow in conventional and newer intelligent transportation systems (ITS); obtained state-of-the-art detectors and inst...

  16. Real-time incident detection using social media data.

    DOT National Transportation Integrated Search

    2016-05-09

    The effectiveness of traditional incident detection is often limited by sparse sensor coverage, and reporting incidents to emergency response systems : is labor-intensive. This research project mines tweet texts to extract incident information on bot...

  17. Use of Humanized RS-ATL8 Reporter System for Detection of Allergen-Specific IgE Sensitization in Human Food Allergy.

    PubMed

    Ali, Eman Ali; Nakamura, Ryosuke; Falcone, Franco H

    2017-01-01

    Allergen-specific Immunoglobulin E (IgE) determination lies at the heart of diagnosis of sensitization to food and other allergens. In the past few years, reporter systems capable of detecting the presence of allergen-specific IgE have been developed by several labs. These rely on humanized rat basophil leukemia cell lines stably transfected with reporter genes such as firefly luciferase. In this chapter, we describe protocols for the use of the RS-ATL8 cell line (IgE cross-linking-induced luciferase expression; EXiLE) in 96-well and 384-well formats. We also describe optional treatment steps for enveloped virus and complement inactivation.

  18. [Study on the timeliness of detection and reporting on public health emergency events in China].

    PubMed

    Li, Ke-Li; Feng, Zi-Jian; Ni, Da-Xin

    2009-03-01

    To analyze the timeliness of detection and reporting on public health emergency events, and to explore the effective strategies for improving the relative capacity on those issues. We conducted a retrospective survey on 3275 emergency events reported through Public Health Emergency Events Surveillance System from 2005 to the first half of 2006. Developed by county Centers for Disease Control and Prevention, a uniformed self-administrated questionnaire was used to collect data, which would include information on the detection, reporting of the events. For communicable diseases events, the median of time interval between the occurrence of first case and the detection of event was 6 days (P25 = 2, P75 = 13). For food poisoning events and clusters of disease with unknown origin, the medians were 3 hours (P25, P75 = 16) and 1 days (P25 = 0, P75 = 5). 71.54% of the events were reported by the discoverers within 2 hours after the detection. In general, the ranges of time intervals between the occurrence, detection or reporting of the events were different, according to the categories of events. The timeliness of detection and reporting of events could have been improved dramatically if the definition of events, according to their characteristics, had been more reasonable and accessible, as well as the improvement of training program for healthcare staff and teachers.

  19. A new surveillance system for undiagnosed serious infectious illness for the London 2012 Olympic and Paralympic Games.

    PubMed

    Heinsbroek, E; Said, B; Kirkbride, H

    2012-08-02

    A new surveillance system was developed to detect possible new or emerging infections presenting as undiagnosed serious infectious illness (USII) for use during the London 2012 Olympic and Paralympic Games. Designated clinicians in sentinel adult and paediatric intensive care units (ICU/ PICUs) reported USII using an online reporting tool or provided a weekly nil notification. Reported cases were investigated for epidemiological links. A pilot study was undertaken for six months between January and July 2011 to evaluate the feasibility and acceptability of the system. In this six-month period, 5 adults and 13 children were reported by six participating units (3 ICUs, 3 PICUs). Of these 18 patients, 12 were reported within four days after admission to an ICU/PICU. Nine patients were subsequently diagnosed and were thus excluded from the surveillance. Therefore, only nine cases of USII were reported. No clustering was identified.On the basis of the pilot study, we conclude that the system is able to detect cases of USII and is feasible and acceptable to users. USII surveillance has been extended to a total of 19 sentinel units in London and the south-east of England during the London 2012 Olympic and Paralympic Games.

  20. Personal Electronic Devices and Their Interference with Aircraft Systems

    NASA Technical Reports Server (NTRS)

    Ross, Elden; Ely, Jay J. (Technical Monitor)

    2001-01-01

    A compilation of data on personal electronic devices (PEDs) attributed to having created anomalies with aircraft systems. Charts and tables display 14 years of incidents reported by pilots to the Aviation Safety Reporting System (ASRS). Affected systems, incident severity, sources of anomaly detection, and the most frequently identified PEDs are some of the more significant data. Several reports contain incidents of aircraft off course when all systems indicated on course and of critical events that occurred during landings and takeoffs. Additionally, PEDs that should receive priority in testing are identified.

  1. Objective-lens-free Fiber-based Position Detection with Nanometer Resolution in a Fiber Optical Trapping System.

    PubMed

    Ti, Chaoyang; Ho-Thanh, Minh-Tri; Wen, Qi; Liu, Yuxiang

    2017-10-13

    Position detection with high accuracy is crucial for force calibration of optical trapping systems. Most existing position detection methods require high-numerical-aperture objective lenses, which are bulky, expensive, and difficult to miniaturize. Here, we report an affordable objective-lens-free, fiber-based position detection scheme with 2 nm spatial resolution and 150 MHz bandwidth. This fiber based detection mechanism enables simultaneous trapping and force measurements in a compact fiber optical tweezers system. In addition, we achieved more reliable signal acquisition with less distortion compared with objective based position detection methods, thanks to the light guiding in optical fibers and small distance between the fiber tips and trapped particle. As a demonstration of the fiber based detection, we used the fiber optical tweezers to apply a force on a cell membrane and simultaneously measure the cellular response.

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Christoph, G.G; Jackson, K.A.; Neuman, M.C.

    An effective method for detecting computer misuse is the automatic auditing and analysis of on-line user activity. This activity is reflected in the system audit record, by changes in the vulnerability posture of the system configuration, and in other evidence found through active testing of the system. In 1989 we started developing an automatic misuse detection system for the Integrated Computing Network (ICN) at Los Alamos National Laboratory. Since 1990 this system has been operational, monitoring a variety of network systems and services. We call it the Network Anomaly Detection and Intrusion Reporter, or NADIR. During the last year andmore » a half, we expanded NADIR to include processing of audit and activity records for the Cray UNICOS operating system. This new component is called the UNICOS Real-time NADIR, or UNICORN. UNICORN summarizes user activity and system configuration information in statistical profiles. In near real-time, it can compare current activity to historical profiles and test activity against expert rules that express our security policy and define improper or suspicious behavior. It reports suspicious behavior to security auditors and provides tools to aid in follow-up investigations. UNICORN is currently operational on four Crays in Los Alamos` main computing network, the ICN.« less

  3. Useful Interplay Between Spontaneous ADR Reports and Electronic Healthcare Records in Signal Detection.

    PubMed

    Pacurariu, Alexandra C; Straus, Sabine M; Trifirò, Gianluca; Schuemie, Martijn J; Gini, Rosa; Herings, Ron; Mazzaglia, Giampiero; Picelli, Gino; Scotti, Lorenza; Pedersen, Lars; Arlett, Peter; van der Lei, Johan; Sturkenboom, Miriam C; Coloma, Preciosa M

    2015-12-01

    Spontaneous reporting systems (SRSs) remain the cornerstone of post-marketing drug safety surveillance despite their well-known limitations. Judicious use of other available data sources is essential to enable better detection, strengthening and validation of signals. In this study, we investigated the potential of electronic healthcare records (EHRs) to be used alongside an SRS as an independent system, with the aim of improving signal detection. A signal detection strategy, focused on a limited set of adverse events deemed important in pharmacovigilance, was performed retrospectively in two data sources-(1) the Exploring and Understanding Adverse Drug Reactions (EU-ADR) database network and (2) the EudraVigilance database-using data between 2000 and 2010. Five events were considered for analysis: (1) acute myocardial infarction (AMI); (2) bullous eruption; (3) hip fracture; (4) acute pancreatitis; and (5) upper gastrointestinal bleeding (UGIB). Potential signals identified in each system were verified using the current published literature. The complementarity of the two systems to detect signals was expressed as the percentage of the unilaterally identified signals out of the total number of confirmed signals. As a proxy for the associated costs, the number of signals that needed to be reviewed to detect one true signal (number needed to detect [NND]) was calculated. The relationship between the background frequency of the events and the capability of each system to detect signals was also investigated. The contribution of each system to signal detection appeared to be correlated with the background incidence of the events, being directly proportional to the incidence in EU-ADR and inversely proportional in EudraVigilance. EudraVigilance was particularly valuable in identifying bullous eruption and acute pancreatitis (71 and 42 % of signals were correctly identified from the total pool of known associations, respectively), while EU-ADR was most useful in identifying hip fractures (60 %). Both systems contributed reasonably well to identification of signals related to UGIB (45 % in EudraVigilance, 40 % in EU-ADR) but only fairly for signals related to AMI (25 % in EU-ADR, 20 % in EudraVigilance). The costs associated with detection of signals were variable across events; however, it was often more costly to detect safety signals in EU-ADR than in EudraVigilance (median NNDs: 7 versus 5). An EHR-based system may have additional value for signal detection, alongside already established systems, especially in the presence of adverse events with a high background incidence. While the SRS appeared to be more cost effective overall, for some events the costs associated with signal detection in the EHR might be justifiable.

  4. Field programmable gate array based fuzzy neural signal processing system for differential diagnosis of QRS complex tachycardia and tachyarrhythmia in noisy ECG signals.

    PubMed

    Chowdhury, Shubhajit Roy

    2012-04-01

    The paper reports of a Field Programmable Gate Array (FPGA) based embedded system for detection of QRS complex in a noisy electrocardiogram (ECG) signal and thereafter differential diagnosis of tachycardia and tachyarrhythmia. The QRS complex has been detected after application of entropy measure of fuzziness to build a detection function of ECG signal, which has been previously filtered to remove power line interference and base line wander. Using the detected QRS complexes, differential diagnosis of tachycardia and tachyarrhythmia has been performed. The entire algorithm has been realized in hardware on an FPGA. Using the standard CSE ECG database, the algorithm performed highly effectively. The performance of the algorithm in respect of QRS detection with sensitivity (Se) of 99.74% and accuracy of 99.5% is achieved when tested using single channel ECG with entropy criteria. The performance of the QRS detection system has been compared and found to be better than most of the QRS detection systems available in literature. Using the system, 200 patients have been diagnosed with an accuracy of 98.5%.

  5. Terahertz imaging system for stand-off detection of threats

    NASA Astrophysics Data System (ADS)

    Hübers, H.-W.; Semenov, A. D.; Richter, H.; Böttger, U.

    2007-04-01

    Suicide bombers and hidden bombs or explosives have become serious threats especially for mass transportation. Until now there exists no established system which can be used against these threats. Therefore new technologies especially for stand-off detection of threats are required. Terahertz (THz) rays offer an alternative inspection method, which can cope with these new challenges. Major advantages of THz radiation as compared to other spectral regions are the possibility to penetrate through clothes and that THz radiation is not harmful for human health. In this report the design and results of a THz stand-off detection system will be presented. The sensor is based on active illumination of the object and sensitive heterodyne detection of reflected and backscattered radiation. The system operates at about 0.8 THz. A THz laser is used for illumination and a superconducting hot-electron bolometric mixer for detection. The local oscillator required for heterodyne detection is a multiplied microwave source. The optical system is designed to allow for stand-off detection at 20 m with a spatial resolution less than 2 cm.

  6. Immunoliposome-PCR: a generic ultrasensitive quantitative antigen detection system

    PubMed Central

    2012-01-01

    Background The accurate quantification of antigens at low concentrations over a wide dynamic range is needed for identifying biomarkers associated with disease and detecting protein interactions in high-throughput microarrays used in proteomics. Here we report the development of an ultrasensitive quantitative assay format called immunoliposome polymerase chain reaction (ILPCR) that fulfills these requirements. This method uses a liposome, with reporter DNA encapsulated inside and biotin-labeled polyethylene glycol (PEG) phospholipid conjugates incorporated into the outer surface of the liposome, as a detection reagent. The antigenic target is immobilized in the well of a microplate by a capture antibody and the liposome detection reagent is then coupled to a biotin-labeled second antibody through a NeutrAvidin bridge. The liposome is ruptured to release the reporter DNA, which serves as a surrogate to quantify the protein target using real-time PCR. Results A liposome detection reagent was prepared, which consisted of a population of liposomes ~120 nm in diameter with each liposome possessing ~800 accessible biotin receptors and ~220 encapsulated reporters. This liposome detection reagent was used in an assay to quantify the concentration of carcinoembryonic antigen (CEA) in human serum. This ILPCR assay exhibited a linear dose–response curve from 10-10 M to 10-16 M CEA. Within this range the assay coefficient of variance was <6 % for repeatability and <2 % for reproducibility. The assay detection limit was 13 fg/mL, which is 1,500-times more sensitive than current clinical assays for CEA. An ILPCR assay to quantify HIV-1 p24 core protein in buffer was also developed. Conclusions The ILPCR assay has several advantages over other immuno-PCR methods. The reporter DNA and biotin-labeled PEG phospholipids spontaneously incorporate into the liposomes as they form, simplifying preparation of the detection reagent. Encapsulation of the reporter inside the liposomes allows nonspecific DNA in the assay medium to be degraded with DNase I prior to quantification of the encapsulated reporter by PCR, which reduces false-positive results and improves quantitative accuracy. The ability to encapsulate multiple reporters per liposome also helps overcome the effect of polymerase inhibitors present in biological specimens. Finally, the biotin-labeled liposome detection reagent can be coupled through a NeutrAvidin bridge to a multitude of biotin-labeled probes, making ILPCR a highly generic assay system. PMID:22726242

  7. Detecting drug-drug interactions using a database for spontaneous adverse drug reactions: an example with diuretics and non-steroidal anti-inflammatory drugs.

    PubMed

    van Puijenbroek, E P; Egberts, A C; Heerdink, E R; Leufkens, H G

    2000-12-01

    Drug-drug interactions are relatively rarely reported to spontaneous reporting systems (SRSs) for adverse drug reactions. For this reason, the traditional approach for analysing SRS has major limitations for the detection of drug-drug interactions. We developed a method that may enable signalling of these possible interactions, which are often not explicitly reported, utilising reports of adverse drug reactions in data sets of SRS. As an example, the influence of concomitant use of diuretics and non-steroidal anti-inflammatory drugs (NSAIDs) on symptoms indicating a decreased efficacy of diuretics was examined using reports received by the Netherlands Pharmacovigilance Foundation Lareb. Reports received between 1 January 1990 and 1 January 1999 of patients older than 50 years were included in the study. Cases were defined as reports with symptoms indicating a decreased efficacy of diuretics, non-cases as all other reports. Exposure categories were the use of NSAIDs or diuretics versus the use of neither of these drugs. The influence of the combined use of both drugs was examined using logistic regression analysis. The odds ratio of the statistical interaction term of the combined use of both drugs was increased [adjusted odds ratio 2.0, 95% confidence interval (CI) 1.1-3.7], which may indicate an enhanced effect of concomitant drug use. The findings illustrate that spontaneous reporting systems have a potential for signal detection and the analysis of possible drug-drug interactions. The method described may enable a more active approach in the detection of drug-drug interactions after marketing.

  8. Altitude deviations: Breakdowns of an error-tolerant system

    NASA Technical Reports Server (NTRS)

    Palmer, Everett A.; Hutchins, Edwin L.; Ritter, Richard D.; Vancleemput, Inge

    1993-01-01

    Pilot reports of aviation incidents to the Aviation Safety Reporting System (ASRS) provide a window on the problems occurring in today's airline cockpits. The narratives of 10 pilot reports of errors made in the automation-assisted altitude-change task are used to illustrate some of the issues of pilots interacting with automatic systems. These narratives are then used to construct a description of the cockpit as an information processing system. The analysis concentrates on the error-tolerant properties of the system and on how breakdowns can occasionally occur. An error-tolerant system can detect and correct its internal processing errors. The cockpit system consists of two or three pilots supported by autoflight, flight-management, and alerting systems. These humans and machines have distributed access to clearance information and perform redundant processing of information. Errors can be detected as deviations from either expected behavior or as deviations from expected information. Breakdowns in this system can occur when the checking and cross-checking tasks that give the system its error-tolerant properties are not performed because of distractions or other task demands. Recommendations based on the analysis for improving the error tolerance of the cockpit system are given.

  9. Comparison of human optimized bacterial luciferase, firefly luciferase, and green fluorescent protein for continuous imaging of cell culture and animal models

    NASA Astrophysics Data System (ADS)

    Close, Dan M.; Hahn, Ruth E.; Patterson, Stacey S.; Baek, Seung J.; Ripp, Steven A.; Sayler, Gary S.

    2011-04-01

    Bioluminescent and fluorescent reporter systems have enabled the rapid and continued growth of the optical imaging field over the last two decades. Of particular interest has been noninvasive signal detection from mammalian tissues under both cell culture and whole animal settings. Here we report on the advantages and limitations of imaging using a recently introduced bacterial luciferase (lux) reporter system engineered for increased bioluminescent expression in the mammalian cellular environment. Comparison with the bioluminescent firefly luciferase (Luc) system and green fluorescent protein system under cell culture conditions demonstrated a reduced average radiance, but maintained a more constant level of bioluminescent output without the need for substrate addition or exogenous excitation to elicit the production of signal. Comparison with the Luc system following subcutaneous and intraperitoneal injection into nude mice hosts demonstrated the ability to obtain similar detection patterns with in vitro experiments at cell population sizes above 2.5 × 104 cells but at the cost of increasing overall image integration time.

  10. What are incident reports telling us? A comparative study at two Australian hospitals of medication errors identified at audit, detected by staff and reported to an incident system.

    PubMed

    Westbrook, Johanna I; Li, Ling; Lehnbom, Elin C; Baysari, Melissa T; Braithwaite, Jeffrey; Burke, Rosemary; Conn, Chris; Day, Richard O

    2015-02-01

    To (i) compare medication errors identified at audit and observation with medication incident reports; (ii) identify differences between two hospitals in incident report frequency and medication error rates; (iii) identify prescribing error detection rates by staff. Audit of 3291 patient records at two hospitals to identify prescribing errors and evidence of their detection by staff. Medication administration errors were identified from a direct observational study of 180 nurses administering 7451 medications. Severity of errors was classified. Those likely to lead to patient harm were categorized as 'clinically important'. Two major academic teaching hospitals in Sydney, Australia. Rates of medication errors identified from audit and from direct observation were compared with reported medication incident reports. A total of 12 567 prescribing errors were identified at audit. Of these 1.2/1000 errors (95% CI: 0.6-1.8) had incident reports. Clinically important prescribing errors (n = 539) were detected by staff at a rate of 218.9/1000 (95% CI: 184.0-253.8), but only 13.0/1000 (95% CI: 3.4-22.5) were reported. 78.1% (n = 421) of clinically important prescribing errors were not detected. A total of 2043 drug administrations (27.4%; 95% CI: 26.4-28.4%) contained ≥ 1 errors; none had an incident report. Hospital A had a higher frequency of incident reports than Hospital B, but a lower rate of errors at audit. Prescribing errors with the potential to cause harm frequently go undetected. Reported incidents do not reflect the profile of medication errors which occur in hospitals or the underlying rates. This demonstrates the inaccuracy of using incident frequency to compare patient risk or quality performance within or across hospitals. New approaches including data mining of electronic clinical information systems are required to support more effective medication error detection and mitigation. © The Author 2015. Published by Oxford University Press in association with the International Society for Quality in Health Care.

  11. Traffic Congestion Detection System through Connected Vehicles and Big Data

    PubMed Central

    Cárdenas-Benítez, Néstor; Aquino-Santos, Raúl; Magaña-Espinoza, Pedro; Aguilar-Velazco, José; Edwards-Block, Arthur; Medina Cass, Aldo

    2016-01-01

    This article discusses the simulation and evaluation of a traffic congestion detection system which combines inter-vehicular communications, fixed roadside infrastructure and infrastructure-to-infrastructure connectivity and big data. The system discussed in this article permits drivers to identify traffic congestion and change their routes accordingly, thus reducing the total emissions of CO2 and decreasing travel time. This system monitors, processes and stores large amounts of data, which can detect traffic congestion in a precise way by means of a series of algorithms that reduces localized vehicular emission by rerouting vehicles. To simulate and evaluate the proposed system, a big data cluster was developed based on Cassandra, which was used in tandem with the OMNeT++ discreet event network simulator, coupled with the SUMO (Simulation of Urban MObility) traffic simulator and the Veins vehicular network framework. The results validate the efficiency of the traffic detection system and its positive impact in detecting, reporting and rerouting traffic when traffic events occur. PMID:27136548

  12. Traffic Congestion Detection System through Connected Vehicles and Big Data.

    PubMed

    Cárdenas-Benítez, Néstor; Aquino-Santos, Raúl; Magaña-Espinoza, Pedro; Aguilar-Velazco, José; Edwards-Block, Arthur; Medina Cass, Aldo

    2016-04-28

    This article discusses the simulation and evaluation of a traffic congestion detection system which combines inter-vehicular communications, fixed roadside infrastructure and infrastructure-to-infrastructure connectivity and big data. The system discussed in this article permits drivers to identify traffic congestion and change their routes accordingly, thus reducing the total emissions of CO₂ and decreasing travel time. This system monitors, processes and stores large amounts of data, which can detect traffic congestion in a precise way by means of a series of algorithms that reduces localized vehicular emission by rerouting vehicles. To simulate and evaluate the proposed system, a big data cluster was developed based on Cassandra, which was used in tandem with the OMNeT++ discreet event network simulator, coupled with the SUMO (Simulation of Urban MObility) traffic simulator and the Veins vehicular network framework. The results validate the efficiency of the traffic detection system and its positive impact in detecting, reporting and rerouting traffic when traffic events occur.

  13. Fiber optic gas detection system for health monitoring of oil-filled transformer

    NASA Astrophysics Data System (ADS)

    Ho, H. L.; Ju, J.; Jin, W.

    2009-10-01

    This paper reports the development of a fiber-optic gas detection system capable of detecting three types of dissolved fault gases in oil-filled power transformers or equipment. The system is based on absorption spectroscopy and the target gases include acetylene (C2H2), methane (CH4) and ethylene (C2H4). Low-cost multi-pass sensor heads using fiber coupled micro-optic cells are employed for which the interaction length is up to 4m. Also, reference gas cells made of photonic bandgap (PBG) fiber are implemented. The minimum detectable gas concentrations for methane, acetylene and ethylene are 5ppm, 2ppm and 50ppm respectively.

  14. Runway Safety Monitor Algorithm for Runway Incursion Detection and Alerting

    NASA Technical Reports Server (NTRS)

    Green, David F., Jr.; Jones, Denise R. (Technical Monitor)

    2002-01-01

    The Runway Safety Monitor (RSM) is an algorithm for runway incursion detection and alerting that was developed in support of NASA's Runway Incursion Prevention System (RIPS) research conducted under the NASA Aviation Safety Program's Synthetic Vision System element. The RSM algorithm provides pilots with enhanced situational awareness and warnings of runway incursions in sufficient time to take evasive action and avoid accidents during landings, takeoffs, or taxiing on the runway. The RSM currently runs as a component of the NASA Integrated Display System, an experimental avionics software system for terminal area and surface operations. However, the RSM algorithm can be implemented as a separate program to run on any aircraft with traffic data link capability. The report documents the RSM software and describes in detail how RSM performs runway incursion detection and alerting functions for NASA RIPS. The report also describes the RIPS flight tests conducted at the Dallas-Ft Worth International Airport (DFW) during September and October of 2000, and the RSM performance results and lessons learned from those flight tests.

  15. Evaluation of computer-aided detection and diagnosis systems.

    PubMed

    Petrick, Nicholas; Sahiner, Berkman; Armato, Samuel G; Bert, Alberto; Correale, Loredana; Delsanto, Silvia; Freedman, Matthew T; Fryd, David; Gur, David; Hadjiiski, Lubomir; Huo, Zhimin; Jiang, Yulei; Morra, Lia; Paquerault, Sophie; Raykar, Vikas; Samuelson, Frank; Summers, Ronald M; Tourassi, Georgia; Yoshida, Hiroyuki; Zheng, Bin; Zhou, Chuan; Chan, Heang-Ping

    2013-08-01

    Computer-aided detection and diagnosis (CAD) systems are increasingly being used as an aid by clinicians for detection and interpretation of diseases. Computer-aided detection systems mark regions of an image that may reveal specific abnormalities and are used to alert clinicians to these regions during image interpretation. Computer-aided diagnosis systems provide an assessment of a disease using image-based information alone or in combination with other relevant diagnostic data and are used by clinicians as a decision support in developing their diagnoses. While CAD systems are commercially available, standardized approaches for evaluating and reporting their performance have not yet been fully formalized in the literature or in a standardization effort. This deficiency has led to difficulty in the comparison of CAD devices and in understanding how the reported performance might translate into clinical practice. To address these important issues, the American Association of Physicists in Medicine (AAPM) formed the Computer Aided Detection in Diagnostic Imaging Subcommittee (CADSC), in part, to develop recommendations on approaches for assessing CAD system performance. The purpose of this paper is to convey the opinions of the AAPM CADSC members and to stimulate the development of consensus approaches and "best practices" for evaluating CAD systems. Both the assessment of a standalone CAD system and the evaluation of the impact of CAD on end-users are discussed. It is hoped that awareness of these important evaluation elements and the CADSC recommendations will lead to further development of structured guidelines for CAD performance assessment. Proper assessment of CAD system performance is expected to increase the understanding of a CAD system's effectiveness and limitations, which is expected to stimulate further research and development efforts on CAD technologies, reduce problems due to improper use, and eventually improve the utility and efficacy of CAD in clinical practice.

  16. Neural network model for automatic traffic incident detection : final report, August 2001.

    DOT National Transportation Integrated Search

    2001-08-01

    Automatic freeway incident detection is an important component of advanced transportation management systems (ATMS) that provides information for emergency relief and traffic control and management purposes. In this research, a multi-paradigm intelli...

  17. Stereoroentgenographic System With Portable Calibration Cage For Use In Clinical Medicine

    NASA Astrophysics Data System (ADS)

    Moffitt, Francis; Baumrind, Sheldon; Chafetz, Neil; Curry, Sean

    1983-07-01

    For the past five years, we have been accumulating information on the performance of a stereoroentgenographic system developed for use in clinical medicine and first reported at the NATO Symposium on the Application of Human Biostereometrics. This system represents an adaptation of normal case coplanar stereometry and involves the use of a single emitter which is displaced in a controlled fashion between exposures. The system has been used primarily for the detection of applicance loosening and settling following the placement of total hip protheses and also for the detection of pseudorthosis following lumbo-sacral fusion. One major goal has been the development of a data acquisition and analysis system suitable for general hospital use which can be operated by technicians without specialized photogrammetric training. This report will focus on system design and on the delineation of technical problems encountered during routine clinical use of the system.

  18. Natural Language Processing Accurately Calculates Adenoma and Sessile Serrated Polyp Detection Rates.

    PubMed

    Nayor, Jennifer; Borges, Lawrence F; Goryachev, Sergey; Gainer, Vivian S; Saltzman, John R

    2018-07-01

    ADR is a widely used colonoscopy quality indicator. Calculation of ADR is labor-intensive and cumbersome using current electronic medical databases. Natural language processing (NLP) is a method used to extract meaning from unstructured or free text data. (1) To develop and validate an accurate automated process for calculation of adenoma detection rate (ADR) and serrated polyp detection rate (SDR) on data stored in widely used electronic health record systems, specifically Epic electronic health record system, Provation ® endoscopy reporting system, and Sunquest PowerPath pathology reporting system. Screening colonoscopies performed between June 2010 and August 2015 were identified using the Provation ® reporting tool. An NLP pipeline was developed to identify adenomas and sessile serrated polyps (SSPs) on pathology reports corresponding to these colonoscopy reports. The pipeline was validated using a manual search. Precision, recall, and effectiveness of the natural language processing pipeline were calculated. ADR and SDR were then calculated. We identified 8032 screening colonoscopies that were linked to 3821 pathology reports (47.6%). The NLP pipeline had an accuracy of 100% for adenomas and 100% for SSPs. Mean total ADR was 29.3% (range 14.7-53.3%); mean male ADR was 35.7% (range 19.7-62.9%); and mean female ADR was 24.9% (range 9.1-51.0%). Mean total SDR was 4.0% (0-9.6%). We developed and validated an NLP pipeline that accurately and automatically calculates ADRs and SDRs using data stored in Epic, Provation ® and Sunquest PowerPath. This NLP pipeline can be used to evaluate colonoscopy quality parameters at both individual and practice levels.

  19. Performance analysis of a multispectral framing camera for detecting mines in the littoral zone and beach zone

    NASA Astrophysics Data System (ADS)

    Louchard, Eric; Farm, Brian; Acker, Andrew

    2008-04-01

    BAE Systems Sensor Systems Identification & Surveillance (IS) has developed, under contract with the Office of Naval Research, a multispectral airborne sensor system and processing algorithms capable of detecting mine-like objects in the surf zone and land mines in the beach zone. BAE Systems has used this system in a blind test at a test range established by the Naval Surface Warfare Center - Panama City Division (NSWC-PCD) at Eglin Air Force Base. The airborne and ground subsystems used in this test are described, with graphical illustrations of the detection algorithms. We report on the performance of the system configured to operate with a human operator analyzing data on a ground station. A subsurface (underwater bottom proud mine in the surf zone and moored mine in shallow water) mine detection capability is demonstrated in the surf zone. Surface float detection and proud land mine detection capability is also demonstrated. Our analysis shows that this BAE Systems-developed multispectral airborne sensor provides a robust technical foundation for a viable system for mine counter-measures, and would be a valuable asset for use prior to an amphibious assault.

  20. Development of a Landmine Detection Sensor Final Report CRADA No. TC02133.0

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Romero, C. E.; Sheppard, C.

    2017-09-06

    This was one of two CRADAs between Lawrence Livermore National Security, LLC as manager and operator of Lawrence Livermore National Laboratory (LLNL) and First Alliance Technologies, LLC (First Alliance), to conduct research and development activity toward an integrated system for the detecting, locating, and destroying of landmines and unexploded ordinance using a laser to destroy landmines and unexploded ordinance and First Alliance’s Land Mine Locator (LML) system. The focus of this CRADA was on developing a sensor system that accurately detects landmines, and provides exact location information in a timely manner with extreme reliability.

  1. Evaluation of a National Call Center and a Local Alerts System for Detection of New Cases of Ebola Virus Disease - Guinea, 2014-2015

    DTIC Science & Technology

    2016-03-11

    Control and Prevention Evaluation of a National Call Center and a Local Alerts System for Detection of New Cases of Ebola Virus Disease — Guinea, 2014...principally through the use of a telephone alert system. Community members and health facilities report deaths and suspected Ebola cases to local alert ...sensitivity of the national call center with the local alerts system, the CDC country team performed probabilistic record linkage of the combined

  2. Army Contracting Officials Could Have Purchased Husky Mounted Detection System Spare Parts at Lower Prices (Redacted)

    DTIC Science & Technology

    2016-03-31

    system mounted on an armored vehicle . It detects and marks landmines and other buried explosive hazards, and serves an important role in keeping...countries. Figure 1. HMDS Shown on a Husky Vehicle Source: Project Manager Close Combat Systems FOR OFFICIAL USE ONLY FOR OFFICIAL USE ONLY Introduction...Reasonable Prices From Meggitt Aircraft Braking Systems for Sole-Source Commercial Spare Parts,” May 8, 2015 Report No. DODIG-2015-103, “Summary of

  3. Hazard detection and avoidance sensor for NASA's planetary landers

    NASA Technical Reports Server (NTRS)

    Lau, Brian; Chao, Tien-Hsin

    1992-01-01

    An optical terrain analysis based sensor system specifically designed for landing hazard detection as required for NASA's autonomous planetary landers is introduced. This optical hazard detection and avoidance (HDA) sensor utilizes an optoelectronic wedge-and-ting (WRD) filter for Fourier transformed feature extraction and an electronic neural network processor for pattern classification. A fully implemented optical HDA sensor would assure safe landing of the planetary landers. Computer simulation results of a successful feasibility study is reported. Future research for hardware system implementation is also provided.

  4. TxDOT Video Analytics System User Manual

    DOT National Transportation Integrated Search

    2012-08-01

    The TxDOT video analytics demonstration system is designed to monitor traffic conditions by collecting data such as speed and counts, detecting incidents such as stopped vehicles and reporting such incidents to system administrators. : As illustrated...

  5. Photonic Generation and Detection of Arbitrary MMW Waveform for High-Resolution MMW Radar Imaging

    DTIC Science & Technology

    2014-12-06

    20ft ~ 2cm Destribution A: Approved for public release. Distribution is unlimited. Fig. 1. The system setup for our MMW arbitrary waveform generation...IOA(AOARD) 11. SPONSOR/MONITOR’S REPORT NUMBER(S) AOARD-134088 12. DISTRIBUTION/AVAILABILITY STATEMENT Destribution A: Approved for public...traveling carrier photodiode (NBUTC-PD), advanced optical pulse shaper system , and ultrafast TDS system to demonstrate the photonic generation and detection

  6. Lightning studies using LDAR and LLP data

    NASA Technical Reports Server (NTRS)

    Forbes, Gregory S.

    1993-01-01

    This study intercompared lightning data from LDAR and LLP systems in order to learn more about the spatial relationships between thunderstorm electrical discharges aloft and lightning strikes to the surface. The ultimate goal of the study is to provide information that can be used to improve the process of real-time detection and warning of lightning by weather forecasters who issue lightning advisories. The Lightning Detection and Ranging (LDAR) System provides data on electrical discharges from thunderstorms that includes cloud-ground flashes as well as lightning aloft (within cloud, cloud-to-cloud, and sometimes emanating from cloud to clear air outside or above cloud). The Lightning Location and Protection (LLP) system detects primarily ground strikes from lightning. Thunderstorms typically produce LDAR signals aloft prior to the first ground strike, so that knowledge of preferred positions of ground strikes relative to the LDAR data pattern from a thunderstorm could allow advance estimates of enhanced ground strike threat. Studies described in the report examine the position of LLP-detected ground strikes relative to the LDAR data pattern from the thunderstorms. The report also describes other potential approaches to the use of LDAR data in the detection and forecasting of lightning ground strikes.

  7. Biogenic unmodified gold nanoparticles for selective and quantitative detection of cerium using UV-vis spectroscopy and photon correlation spectroscopy (DLS).

    PubMed

    Priyadarshini, E; Pradhan, N; Panda, P K; Mishra, B K

    2015-06-15

    The ability of self-functionalized biogenic GNPs towards highly selective colorimetric detection of rare earth element cerium is being reported for the first time. GNPs underwent rapid aggregation on addition of cerium indicated by red shift of SPR peak followed by complete precipitation. Hereby, this concept of co-ordination of cerium ions onto the GNP surface has been utilized for detection of cerium. The remarkable capacity of GNPs to sensitively detect Ce without proves beneficial compared to previous reports of colorimetric sensing. MDL was 15 and 35 ppm by DLS and UV-vis spectroscopy respectively, suggesting DLS to be highly sensitive and a practical alternative in ultrasensitive detection studies. The sensing system showed a good linear fit favouring feasible detection of cerium in range of 2-50 ppm. Similar studies further showed the superior selectivity of biogenic GNPs compared to chemically synthesized counterparts. The sensing system favours on-site analysis as it overcomes need of complex instrumentation, lengthy protocols and surface modification of GNP. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. A Fiber-Optic Probe Design for Combustion Chamber Flame Detection Applications-Design Criteria, Performance Specifications, and Fabrication Technique

    NASA Technical Reports Server (NTRS)

    Borg, Stephen E.; Harper, Samuel E.

    2001-01-01

    This paper documents the design and development of the fiber-optic probes utilized in the flame detection systems used in NASA Langley Research Center's 8-Foot High Temperature Tunnel (8-ft HTT). Two independent flame detection systems are utilized to monitor the presence and stability of the main-burner and pilot-level flames during facility operation. Due to the harsh environment within the combustor, the successful development of a rugged and efficient fiber-optic probe was a critical milestone in the development of these flame detection systems. The final optical probe design for the two flame detection systems resulted from research that was conducted in Langley's 7-in High Temperature Pilot Tunnel (7-in HTT). A detailed description of the manufacturing process behind the optical probes used in the 8-ft HTT is provided in Appendix A of this report.

  9. Detection of forced oscillations in power systems with multichannel methods

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Follum, James D.

    2015-09-30

    The increasing availability of high fidelity, geographically dispersed measurements in power systems improves the ability of researchers and engineers to study dynamic behaviors in the grid. One such behavior that is garnering increased attention is the presence of forced oscillations. Power system engineers are interested in forced oscillations because they are often symptomatic of the malfunction or misoperation of equipment. Though the resulting oscillation is not always large in amplitude, the root cause may be serious. In this report, multi-channel forced oscillation detection methods are developed. These methods leverage previously developed detection approaches based on the periodogram and spectral-coherence. Makingmore » use of geographically distributed channels of data is shown to improved detection performance and shorten the delay before an oscillation can be detected in the online environment. Results from simulated and measured power system data are presented.« less

  10. Management System of Occupational Diseases in Korea: Statistics, Report and Monitoring System

    PubMed Central

    Choe, Seong Weon

    2010-01-01

    The management system of occupational diseases in Korea can be assessed from the perspective of a surveillance system. Workers' compensation insurance reports are used to produce official statistics on occupational diseases in Korea. National working conditions surveys are used to monitor the magnitude of work-related symptoms and signs in the labor force. A health examination program was introduced to detect occupational diseases through both selective and mass screening programs. The Working Environment Measurement Institution assesses workers' exposure to hazards in the workplace. Government regulates that the employer should do health examinations and working conditions measurement through contracted private agencies and following the Occupational Safety and Health Act. It is hoped that these institutions may be able to effectively detect and monitor occupational diseases and hazards in the workplace. In view of this, the occupational management system in Korea is well designed, except for the national survey system. In the future, national surveys for detection of hazards and ill-health outcomes in workers should be developed. The existing surveillance system for occupational disease can be improved by providing more refined information through statistical analysis of surveillance data. PMID:21258584

  11. Ancho Canyon RF Collect, March 2, 2017: Final Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Junor, William; Layne, John Preston; Gamble, Thomas Kirk

    2017-09-21

    We report the results from the March 2, 2017, Ancho Canyon RF collection. While bright electromagnetic signals were seen nearby the firing point, there were no detections of signals from the explosively-fired fuse at a collection point about 570m distant on the East Mesa. However, "liveness" tests of the East Mesa data acquisition system and checks of the timing both suggest that the collection system was working correctly. We examine possible reasons for the lack of detection. Principal among these is that the impulsive signal may be small compared to the radio frequency background on the East Mesa.

  12. Evaluation of computer-aided detection and diagnosis systemsa)

    PubMed Central

    Petrick, Nicholas; Sahiner, Berkman; Armato, Samuel G.; Bert, Alberto; Correale, Loredana; Delsanto, Silvia; Freedman, Matthew T.; Fryd, David; Gur, David; Hadjiiski, Lubomir; Huo, Zhimin; Jiang, Yulei; Morra, Lia; Paquerault, Sophie; Raykar, Vikas; Samuelson, Frank; Summers, Ronald M.; Tourassi, Georgia; Yoshida, Hiroyuki; Zheng, Bin; Zhou, Chuan; Chan, Heang-Ping

    2013-01-01

    Computer-aided detection and diagnosis (CAD) systems are increasingly being used as an aid by clinicians for detection and interpretation of diseases. Computer-aided detection systems mark regions of an image that may reveal specific abnormalities and are used to alert clinicians to these regions during image interpretation. Computer-aided diagnosis systems provide an assessment of a disease using image-based information alone or in combination with other relevant diagnostic data and are used by clinicians as a decision support in developing their diagnoses. While CAD systems are commercially available, standardized approaches for evaluating and reporting their performance have not yet been fully formalized in the literature or in a standardization effort. This deficiency has led to difficulty in the comparison of CAD devices and in understanding how the reported performance might translate into clinical practice. To address these important issues, the American Association of Physicists in Medicine (AAPM) formed the Computer Aided Detection in Diagnostic Imaging Subcommittee (CADSC), in part, to develop recommendations on approaches for assessing CAD system performance. The purpose of this paper is to convey the opinions of the AAPM CADSC members and to stimulate the development of consensus approaches and “best practices” for evaluating CAD systems. Both the assessment of a standalone CAD system and the evaluation of the impact of CAD on end-users are discussed. It is hoped that awareness of these important evaluation elements and the CADSC recommendations will lead to further development of structured guidelines for CAD performance assessment. Proper assessment of CAD system performance is expected to increase the understanding of a CAD system's effectiveness and limitations, which is expected to stimulate further research and development efforts on CAD technologies, reduce problems due to improper use, and eventually improve the utility and efficacy of CAD in clinical practice. PMID:23927365

  13. Automated baseline change detection -- Phases 1 and 2. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Byler, E.

    1997-10-31

    The primary objective of this project is to apply robotic and optical sensor technology to the operational inspection of mixed toxic and radioactive waste stored in barrels, using Automated Baseline Change Detection (ABCD), based on image subtraction. Absolute change detection is based on detecting any visible physical changes, regardless of cause, between a current inspection image of a barrel and an archived baseline image of the same barrel. Thus, in addition to rust, the ABCD system can also detect corrosion, leaks, dents, and bulges. The ABCD approach and method rely on precise camera positioning and repositioning relative to the barrelmore » and on feature recognition in images. The ABCD image processing software was installed on a robotic vehicle developed under a related DOE/FETC contract DE-AC21-92MC29112 Intelligent Mobile Sensor System (IMSS) and integrated with the electronics and software. This vehicle was designed especially to navigate in DOE Waste Storage Facilities. Initial system testing was performed at Fernald in June 1996. After some further development and more extensive integration the prototype integrated system was installed and tested at the Radioactive Waste Management Facility (RWMC) at INEEL beginning in April 1997 through the present (November 1997). The integrated system, composed of ABCD imaging software and IMSS mobility base, is called MISS EVE (Mobile Intelligent Sensor System--Environmental Validation Expert). Evaluation of the integrated system in RWMC Building 628, containing approximately 10,000 drums, demonstrated an easy to use system with the ability to properly navigate through the facility, image all the defined drums, and process the results into a report delivered to the operator on a GUI interface and on hard copy. Further work is needed to make the brassboard system more operationally robust.« less

  14. A molecular rotor based ratiometric sensor for basic amino acids

    NASA Astrophysics Data System (ADS)

    Pettiwala, Aafrin M.; Singh, Prabhat K.

    2018-01-01

    The inevitable importance of basic amino acids, arginine and lysine, in human health and metabolism demands construction of efficient sensor systems for them. However, there are only limited reports on the 'ratiometric' detection of basic amino acids which is further restricted by the use of chemically complex sensor molecules, which impedes their prospect for practical applications. Herein, we report a ratiometric sensor system build on simple mechanism of disassociation of novel emissive Thioflavin-T H-aggregates from heparin surface, when subjected to interaction with basic amino acids. The strong and selective electrostatic and hydrogen bonding interaction of basic amino acids with heparin leads to large alteration in photophysical attributes of heparin bound Thioflavin-T, which forms a highly sensitive sensor platform for detection of basic amino acids in aqueous solution. These selective interactions between basic amino acids and heparin allow our sensor system to discriminate arginine and lysine from other amino acids. This unique mechanism of dissociation of Thioflavin-T aggregates from heparin surface provides ratiometric response on both fluorimetric and colorimetric outputs for detection of arginine and lysine, and thus it holds a significant advantage over other developed sensor systems which are restricted to single wavelength detection. Apart from the sensitivity and selectivity, our system also provides the advantage of simplicity, dual mode of sensing, and more importantly, it employs an inexpensive commercially available probe molecule, which is a significant advantage over other developed sensor systems that uses tedious synthesis protocol for the employed probe in the detection scheme, an impediment for practical applications. Additionally, our sensor system also shows response in complex biological media of serum samples.

  15. Signal Detection of Imipenem Compared to Other Drugs from Korea Adverse Event Reporting System Database

    PubMed Central

    Park, Kyounghoon; Soukavong, Mick; Kim, Jungmee; Kwon, Kyoung-eun; Jin, Xue-mei; Lee, Joongyub; Yang, Bo Ram

    2017-01-01

    Purpose To detect signals of adverse drug events after imipenem treatment using the Korea Institute of Drug Safety & Risk Management-Korea adverse event reporting system database (KIDS-KD). Materials and Methods We performed data mining using KIDS-KD, which was constructed using spontaneously reported adverse event (AE) reports between December 1988 and June 2014. We detected signals calculated the proportional reporting ratio, reporting odds ratio, and information component of imipenem. We defined a signal as any AE that satisfied all three indices. The signals were compared with drug labels of nine countries. Results There were 807582 spontaneous AEs reports in the KIDS-KD. Among those, the number of antibiotics related AEs was 192510; 3382 reports were associated with imipenem. The most common imipenem-associated AE was the drug eruption; 353 times. We calculated the signal by comparing with all other antibiotics and drugs; 58 and 53 signals satisfied the three methods. We compared the drug labelling information of nine countries, including the USA, the UK, Japan, Italy, Switzerland, Germany, France, Canada, and South Korea, and discovered that the following signals were currently not included in drug labels: hypokalemia, cardiac arrest, cardiac failure, Parkinson's syndrome, myocardial infarction, and prostate enlargement. Hypokalemia was an additional signal compared with all other antibiotics, and the other signals were not different compared with all other antibiotics and all other drugs. Conclusion We detected new signals that were not listed on the drug labels of nine countries. However, further pharmacoepidemiologic research is needed to evaluate the causality of these signals. PMID:28332362

  16. Signal Detection of Imipenem Compared to Other Drugs from Korea Adverse Event Reporting System Database.

    PubMed

    Park, Kyounghoon; Soukavong, Mick; Kim, Jungmee; Kwon, Kyoung Eun; Jin, Xue Mei; Lee, Joongyub; Yang, Bo Ram; Park, Byung Joo

    2017-05-01

    To detect signals of adverse drug events after imipenem treatment using the Korea Institute of Drug Safety & Risk Management-Korea adverse event reporting system database (KIDS-KD). We performed data mining using KIDS-KD, which was constructed using spontaneously reported adverse event (AE) reports between December 1988 and June 2014. We detected signals calculated the proportional reporting ratio, reporting odds ratio, and information component of imipenem. We defined a signal as any AE that satisfied all three indices. The signals were compared with drug labels of nine countries. There were 807582 spontaneous AEs reports in the KIDS-KD. Among those, the number of antibiotics related AEs was 192510; 3382 reports were associated with imipenem. The most common imipenem-associated AE was the drug eruption; 353 times. We calculated the signal by comparing with all other antibiotics and drugs; 58 and 53 signals satisfied the three methods. We compared the drug labelling information of nine countries, including the USA, the UK, Japan, Italy, Switzerland, Germany, France, Canada, and South Korea, and discovered that the following signals were currently not included in drug labels: hypokalemia, cardiac arrest, cardiac failure, Parkinson's syndrome, myocardial infarction, and prostate enlargement. Hypokalemia was an additional signal compared with all other antibiotics, and the other signals were not different compared with all other antibiotics and all other drugs. We detected new signals that were not listed on the drug labels of nine countries. However, further pharmacoepidemiologic research is needed to evaluate the causality of these signals. © Copyright: Yonsei University College of Medicine 2017

  17. Causes of Outbreaks Associated with Drinking Water in the United States from 1971 to 2006

    PubMed Central

    Craun, Gunther F.; Brunkard, Joan M.; Yoder, Jonathan S.; Roberts, Virginia A.; Carpenter, Joe; Wade, Tim; Calderon, Rebecca L.; Roberts, Jacquelin M.; Beach, Michael J.; Roy, Sharon L.

    2010-01-01

    Summary: Since 1971, the CDC, EPA, and Council of State and Territorial Epidemiologists (CSTE) have maintained the collaborative national Waterborne Disease and Outbreak Surveillance System (WBDOSS) to document waterborne disease outbreaks (WBDOs) reported by local, state, and territorial health departments. WBDOs were recently reclassified to better characterize water system deficiencies and risk factors; data were analyzed for trends in outbreak occurrence, etiologies, and deficiencies during 1971 to 2006. A total of 833 WBDOs, 577,991 cases of illness, and 106 deaths were reported during 1971 to 2006. Trends of public health significance include (i) a decrease in the number of reported outbreaks over time and in the annual proportion of outbreaks reported in public water systems, (ii) an increase in the annual proportion of outbreaks reported in individual water systems and in the proportion of outbreaks associated with premise plumbing deficiencies in public water systems, (iii) no change in the annual proportion of outbreaks associated with distribution system deficiencies or the use of untreated and improperly treated groundwater in public water systems, and (iv) the increasing importance of Legionella since its inclusion in WBDOSS in 2001. Data from WBDOSS have helped inform public health and regulatory responses. Additional resources for waterborne disease surveillance and outbreak detection are essential to improve our ability to monitor, detect, and prevent waterborne disease in the United States. PMID:20610821

  18. A Participatory System for Preventing Pandemics of Animal Origins: Pilot Study of the Participatory One Health Disease Detection (PODD) System.

    PubMed

    Yano, Terdsak; Phornwisetsirikun, Somphorn; Susumpow, Patipat; Visrutaratna, Surasing; Chanachai, Karoon; Phetra, Polawat; Chaisowwong, Warangkhana; Trakarnsirinont, Pairat; Hemwan, Phonpat; Kaewpinta, Boontuan; Singhapreecha, Charuk; Kreausukon, Khwanchai; Charoenpanyanet, Arisara; Robert, Chongchit Sripun; Robert, Lamar; Rodtian, Pranee; Mahasing, Suteerat; Laiya, Ekkachai; Pattamakaew, Sakulrat; Tankitiyanon, Taweesart; Sansamur, Chalutwan; Srikitjakarn, Lertrak

    2018-03-21

    Aiming for early disease detection and prompt outbreak control, digital technology with a participatory One Health approach was used to create a novel disease surveillance system called Participatory One Health Disease Detection (PODD). PODD is a community-owned surveillance system that collects data from volunteer reporters; identifies disease outbreak automatically; and notifies the local governments (LGs), surrounding villages, and relevant authorities. This system provides a direct and immediate benefit to the communities by empowering them to protect themselves. The objective of this study was to determine the effectiveness of the PODD system for the rapid detection and control of disease outbreaks. The system was piloted in 74 LGs in Chiang Mai, Thailand, with the participation of 296 volunteer reporters. The volunteers and LGs were key participants in the piloting of the PODD system. Volunteers monitored animal and human diseases, as well as environmental problems, in their communities and reported these events via the PODD mobile phone app. LGs were responsible for outbreak control and provided support to the volunteers. Outcome mapping was used to evaluate the performance of the LGs and volunteers. LGs were categorized into one of the 3 groups based on performance: A (good), B (fair), and C (poor), with the majority (46%,34/74) categorized into group B. Volunteers were similarly categorized into 4 performance groups (A-D), again with group A showing the best performance, with the majority categorized into groups B and C. After 16 months of implementation, 1029 abnormal events had been reported and confirmed to be true reports. The majority of abnormal reports were sick or dead animals (404/1029, 39.26%), followed by zoonoses and other human diseases (129/1029, 12.54%). Many potentially devastating animal disease outbreaks were detected and successfully controlled, including 26 chicken high mortality outbreaks, 4 cattle disease outbreaks, 3 pig disease outbreaks, and 3 fish disease outbreaks. In all cases, the communities and animal authorities cooperated to apply community contingency plans to control these outbreaks, and community volunteers continued to monitor the abnormal events for 3 weeks after each outbreak was controlled. By design, PODD initially targeted only animal diseases that potentially could emerge into human pandemics (eg, avian influenza) and then, in response to community needs, expanded to cover human health and environmental health issues. ©Terdsak Yano, Somphorn Phornwisetsirikun, Patipat Susumpow, Surasing Visrutaratna, Karoon Chanachai, Polawat Phetra, Warangkhana Chaisowwong, Pairat Trakarnsirinont, Phonpat Hemwan, Boontuan Kaewpinta, Charuk Singhapreecha, Khwanchai Kreausukon, Arisara  Charoenpanyanet, Chongchit Sripun Robert, Lamar Robert, Pranee Rodtian, Suteerat Mahasing, Ekkachai Laiya, Sakulrat Pattamakaew, Taweesart Tankitiyanon, Chalutwan Sansamur, Lertrak Srikitjakarn. Originally published in JMIR Public Health and Surveillance (http://publichealth.jmir.org), 21.03.2018.

  19. An improved method for direct estimation of free cyanide in drinking water by Ion Chromatography-Pulsed Amperometry Detection (IC-PAD) on gold working electrode.

    PubMed

    Kumar Meher, Alok; Labhsetwar, Nitin; Bansiwal, Amit

    2018-02-01

    In the present work a fast, reliable and safe Ion Exchange Chromatography-Pulsed Amperometry Detection (IC-PAD) method for direct determination of free cyanide in drinking water has been reported. To the best of our knowledge for the first time we are reporting the application of Gold working electrode for detection of free cyanide in a chromatography system. The system shows a wide linear range up to 8000µg/L. The electrode was found to have improved sensitivity and selectivity in the presence of interfering ions. The detection limit of the system was calculated to be 2µg/L. Long term evaluation of the electrode was found to be stable. Reproducible results were obtained from analysis of drinking water samples with recoveries of 98.3-101.2% and Relative Standard Deviations (RSD) of <2%. This study proves the potential application of the newly developed method for the analysis of free cyanide in drinking water. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Detection systems for carbapenemase gene identification should include the SME serine carbapenemase.

    PubMed

    Bush, Karen; Pannell, Megan; Lock, John L; Queenan, Anne Marie; Jorgensen, James H; Lee, Ryan M; Lewis, James S; Jarrett, Deidre

    2013-01-01

    Carbapenemase detection has become a major problem in hospitals that encounter outbreaks of infections caused by carbapenem-resistant Gram-negative bacteria. Rapid detection systems have been reported using multiplex PCR analyses and DNA microarray assays. Major carbapenemases that are detected by these systems include the KPC and OXA serine carbapenemases, and the IMP, VIM and NDM families of metallo-β-lactamases. However, increasing numbers of the SME serine carbapenemase are being reported from Serratia marcescens, especially from North and South America. These organisms differ from many of the other carbapenemase-producing pathogens in that they are generally susceptible to the expanded-spectrum cephalosporins ceftazidime and cefepime while retaining resistance to almost all other β-lactam antibiotics. Thus, multiplex PCR assays or DNA microarray testing of carbapenem-resistant S. marcescens isolates should include analyses for production of the SME carbapenemase. Confirmation of the presence of this enzyme may provide reassurance that oxyimino-cephalosporins can be considered for treatment of infections caused by these carbapenem-resistant pathogens. Copyright © 2012 Elsevier B.V. and the International Society of Chemotherapy. All rights reserved.

  1. CO and CO2 dual-gas detection based on mid-infrared wideband absorption spectroscopy

    NASA Astrophysics Data System (ADS)

    Dong, Ming; Zhong, Guo-qiang; Miao, Shu-zhuo; Zheng, Chuan-tao; Wang, Yi-ding

    2018-03-01

    A dual-gas sensor system is developed for CO and CO2 detection using a single broadband light source, pyroelectric detectors and time-division multiplexing (TDM) technique. A stepper motor based rotating system and a single-reflection spherical optical mirror are designed and adopted for realizing and enhancing dual-gas detection. Detailed measurements under static detection mode (without rotation) and dynamic mode (with rotation) are performed to study the performance of the sensor system for the two gas samples. The detection period is 7.9 s in one round of detection by scanning the two detectors. Based on an Allan deviation analysis, the 1σ detection limits under static operation are 3.0 parts per million (ppm) in volume and 2.6 ppm for CO and CO2, respectively, and those under dynamic operation are 9.4 ppm and 10.8 ppm for CO and CO2, respectively. The reported sensor has potential applications in various fields requiring CO and CO2 detection such as in the coal mine.

  2. Airborne Windshear Detection and Warning Systems. Fifth and Final Combined Manufacturers' and Technologists' Conference, part 2

    NASA Technical Reports Server (NTRS)

    Delnore, Victor E. (Compiler)

    1994-01-01

    The Fifth Combined Manufacturers' and Technologists' Airborne Windshear Review Meeting was hosted by the NASA Langley Research Center and the Federal Aviation Administration in Hampton, Virginia, on September 28-30, 1993. The purpose was to report on the highly successful windshear experiments conducted by government, academic institutions, and industry; to transfer the results to regulators, manufacturers, and users; and to set initiatives for future aeronautics technology research. The formal sessions covered recent developments in windshear flight testing, windshear modeling, flight management, and ground-based systems, airborne windshear detection systems, certification and regulatory issues, and development and applications of sensors for wake vortices and for synthetic and enhanced vision systems. This report was compiled to record and make available the technology updates and materials from the conference.

  3. SPI/U3.2. Security Profile Inspector for UNIX Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bartoletti, A.

    1994-08-01

    SPI/U3.2 consists of five tools used to assess and report the security posture of computers running the UNIX operating system. The tools are: Access Control Test: A rule-based system which identifies sequential dependencies in UNIX access controls. Binary Authentication Tool: Evaluates the release status of system binaries by comparing a crypto-checksum to provide table entries. Change Detection Tool: Maintains and applies a snapshot of critical system files and attributes for purposes of change detection. Configuration Query Language: Accepts CQL-based scripts (provided) to evaluate queries over the status of system files, configuration of services and many other elements of UNIX systemmore » security. Password Security Inspector: Tests for weak or aged passwords. The tools are packaged with a forms-based user interface providing on-line context-sensistive help, job scheduling, parameter management and output report management utilities. Tools may be run independent of the UI.« less

  4. Comparison of a mobile phone-based malaria reporting system with source participant register data for capturing spatial and temporal trends in epidemiological indicators of malaria transmission collected by community health workers in rural Zambia.

    PubMed

    Hamainza, Busiku; Killeen, Gerry F; Kamuliwo, Mulakwa; Bennett, Adam; Yukich, Joshua O

    2014-12-12

    Timeliness, completeness, and accuracy are key requirements for any surveillance system to reliably monitor disease burden and guide efficient resource prioritization. Evidence that electronic reporting of malaria cases by community health workers (CHWs) meet these requirements remains limited. Residents of two adjacent rural districts in Zambia were provided with both passive and active malaria testing and treatment services with malaria rapid diagnostic tests (RDTs) and artemisinin-based combination therapy by 42 CHWs serving 14 population clusters centred around public sector health facilities. Reference data describing total numbers of RDT-detected infections and diagnostic positivity (DP) were extracted from detailed participant register books kept by CHWs. These were compared with equivalent weekly summaries relayed directly by the CHWs themselves through a mobile phone short messaging system (SMS) reporting platform. Slightly more RDT-detected malaria infections were recorded in extracted participant registers than were reported in weekly mobile phone summaries but the difference was equivalent to only 19.2% (31,665 versus 25,583, respectively). The majority (81%) of weekly SMS reports were received within one week and the remainder within one month. Overall mean [95% confidence limits] difference between the numbers of register-recorded and SMS-reported RDT-detected malaria infections per CHW per week, as estimated by the Bland Altman method, was only -2.3 [-21.9, 17.2]. The mean [range] for both the number of RDT-detected malaria infections (86 [0, 463] versus 73.6 [0, 519], respectively)) and DP (22.8% [0.0 to 96.3%] versus 23.2% [0.4 to 75.8%], respectively) reported by SMS were generally very consistent with those recorded in the reference paper-based register data and exhibited similar seasonality patterns across all study clusters. Overall, mean relative differences in the SMS reports and reference register data were more consistent with each other for DP than for absolute numbers of RDT-detected infections, presumably because this indicator is robust to variations in patient reporting rates by location, weather, season and calendar event because these are included in both the nominator and denominator. The SMS reports captured malaria transmission trends with adequate accuracy and could be used for population-wide, continuous, longitudinal monitoring of malaria transmission.

  5. DETECTION OF FAST RADIO TRANSIENTS WITH MULTIPLE STATIONS: A CASE STUDY USING THE VERY LONG BASELINE ARRAY

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thompson, David R.; Wagstaff, Kiri L.; Majid, Walid A.

    2011-07-10

    Recent investigations reveal an important new class of transient radio phenomena that occur on submillisecond timescales. Often, transient surveys' data volumes are too large to archive exhaustively. Instead, an online automatic system must excise impulsive interference and detect candidate events in real time. This work presents a case study using data from multiple geographically distributed stations to perform simultaneous interference excision and transient detection. We present several algorithms that incorporate dedispersed data from multiple sites, and report experiments with a commensal real-time transient detection system on the Very Long Baseline Array. We test the system using observations of pulsar B0329+54.more » The multiple-station algorithms enhanced sensitivity for detection of individual pulses. These strategies could improve detection performance for a future generation of geographically distributed arrays such as the Australian Square Kilometre Array Pathfinder and the Square Kilometre Array.« less

  6. Lidar/DIAL detection of acetone at 3.3 μm by a tunable OPO laser system

    NASA Astrophysics Data System (ADS)

    Puiu, A.; Fiorani, L.; Rosa, O.; Borelli, R.; Pistilli, M.; Palucci, A.

    2014-08-01

    In this paper we report, for the first time to our knowledge, on lidar/DIAL detection of acetone vapors at 3.3 μm by means of an optical parametric tunable laser system. After a preliminary spectroscopic study in an absorption cell, the feasibility of a differential absorption (DIAL) lidar for the detection of acetone vapors has been investigated in the laboratory, simulating the experimental conditions of a field campaign. Having in mind measurements in a real scenario, a study of possible atmospheric intereferents has been performed, looking for all known compounds that share acetone IR absorption in the spectral band selected for its detection. Possible interfering species from urban and industrial atmospheres were investigated and limits of acetone detection in both environments were identified. This study confirmed that a lidar system can detect a low concentration of acetone at considerable distances.

  7. Application of a CO2 dial system for infrared detection of forest fire and reduction of false alarm

    NASA Astrophysics Data System (ADS)

    Bellecci, C.; Francucci, M.; Gaudio, P.; Gelfusa, M.; Martellucci, S.; Richetta, M.; Lo Feudo, T.

    2007-04-01

    Forest fires can be the cause of serious environmental and economic damages. For this reason considerable effort has been directed toward forest protection and fire fighting. The means traditionally used for early fire detection mainly consist in human observers dispersed over forest regions. A significant improvement in early warning capabilities could be obtained by using automatic detection apparatus. In order to early detect small forest fires and minimize false alarms, the use of a lidar system and dial technique will be considered. A first evaluation of the lowest detectable concentration will be estimated by numerical simulation. The theoretical model will also be used to get the capability of the dial system to control wooded areas. Fixing the burning rate for several fuels, the maximum range of detection will be evaluated. Finally results of simulations will be reported.

  8. Parallel detection experiment of fluorescence confocal microscopy using DMD.

    PubMed

    Wang, Qingqing; Zheng, Jihong; Wang, Kangni; Gui, Kun; Guo, Hanming; Zhuang, Songlin

    2016-05-01

    Parallel detection of fluorescence confocal microscopy (PDFCM) system based on Digital Micromirror Device (DMD) is reported in this paper in order to realize simultaneous multi-channel imaging and improve detection speed. DMD is added into PDFCM system, working to take replace of the single traditional pinhole in the confocal system, which divides the laser source into multiple excitation beams. The PDFCM imaging system based on DMD is experimentally set up. The multi-channel image of fluorescence signal of potato cells sample is detected by parallel lateral scanning in order to verify the feasibility of introducing the DMD into fluorescence confocal microscope. In addition, for the purpose of characterizing the microscope, the depth response curve is also acquired. The experimental result shows that in contrast to conventional microscopy, the DMD-based PDFCM system has higher axial resolution and faster detection speed, which may bring some potential benefits in the biology and medicine analysis. SCANNING 38:234-239, 2016. © 2015 Wiley Periodicals, Inc. © Wiley Periodicals, Inc.

  9. Healthcare Professionals’ Perspectives on Barriers to Elder Abuse Detection and Reporting in Primary Care Settings

    PubMed Central

    SCHMEIDEL, AMY N.; DALY, JEANETTE M.; ROSENBAUM, MARCY E.; SCHMUCH, GRETCHEN A.; JOGERST, GERALD J.

    2012-01-01

    The purpose of this study was to explore through interviews of healthcare professionals their perspectives on elder abuse to achieve a better understanding of the problems of reporting and generate ideas for improving the process. Through a mailed survey, nurses, physicians, and social workers were invited to participate in an interview. Nine nurses, 8 physicians, and 6 social workers were interviewed and thematic analysis was used to identify the following core themes: professional orientation, assessment, interpretation, systems, and knowledge and education. The impact by healthcare professionals in recognizing and reporting elder abuse and obtaining resources for those mistreated can be profound. Nurses tended to perceive elder abuse as uncommon and generally did not feel it was their role nor did they have time to assess patients for potential abuse. Physicians felt that other patient care issues, time limitations and maintaining trust in the clinician-patient relationship outweighed the importance of detecting and pursuing suspected cases of elder abuse. Social workers, although having the most knowledge and experience related to elder abuse, relied on nurses and physicians to detect potential abusive situations and to work with them in making appropriate referrals. The three disciplines acknowledged the need for more and better education about elder abuse detection and reporting. Participants suggested a reorganization of the external reporting system. More frequent and pragmatic education is necessary to strengthen practical knowledge about elder abuse. PMID:22206510

  10. Characterization of polymorphic states in energetic samples of 1,3,5-trinitro-1,3,5-triazine (RDX) fabricated using drop-on-demand inkjet technology.

    PubMed

    Emmons, Erik D; Farrell, Mikella E; Holthoff, Ellen L; Tripathi, Ashish; Green, Norman; Moon, Raphael P; Guicheteau, Jason A; Christesen, Steven D; Pellegrino, Paul M; Fountain, Augustus W

    2012-06-01

    The United States Army and the first responder community are evaluating optical detection systems for the trace detection of hazardous energetic materials. Fielded detection systems must be evaluated with the appropriate material concentrations to accurately identify the residue in theater. Trace levels of energetic materials have been observed in mutable polymorphic phases and, therefore, the systems being evaluated must be able to detect and accurately identify variant sample phases observed in spectral data. In this work, we report on the novel application of drop-on-demand technology for the fabrication of standardized trace 1,3,5-trinitro-1,3,5-triazine (RDX) samples. The drop-on-demand sample fabrication technique is compared both visually and spectrally to the more commonly used drop-and-dry technique. As the drop-on-demand technique allows for the fabrication of trace level hazard materials, concerted efforts focused on characterization of the polymorphic phase changes observed with low concentrations of RDX commonly used in drop-on-demand processing. This information is important when evaluating optical detection technologies using samples prepared with a drop-on-demand inkjet system, as the technology may be "trained" to detect the common bulk α phase of the explosive based on its spectral features but fall short in positively detecting a trace quantity of RDX (β-phase). We report the polymorphic shifts observed between α- and β-phases of this energetic material and discuss the conditions leading to the favoring of one phase over the other.

  11. Flight Tests of the Turbulence Prediction and Warning System (TPAWS)

    NASA Technical Reports Server (NTRS)

    Hamilton, David W.; Proctor, Fred H.; Ahmad, Nashat N.

    2012-01-01

    Flight tests of the National Aeronautics and Space Administration's Turbulence Prediction And Warning System (TPAWS) were conducted in the Fall of 2000 and Spring of 2002. TPAWS is a radar-based airborne turbulence detection system. During twelve flights, NASA's B-757 tallied 53 encounters with convectively induced turbulence. Analysis of data collected during 49 encounters in the Spring of 2002 showed that the TPAWS Airborne Turbulence Detection System (ATDS) successfully detected 80% of the events at least 30 seconds prior to the encounter, achieving FAA recommended performance criteria. Details of the flights, the prevailing weather conditions, and each of the turbulence events are presented in this report. Sensor and environmental characterizations are also provided.

  12. Research reports: 1990 NASA/ASEE Summer Faculty Fellowship Program

    NASA Technical Reports Server (NTRS)

    Anderson, Loren A. (Editor); Beymer, Mark A. (Editor)

    1990-01-01

    A collection of technical reports on research conducted by the participants in this program is presented. The topics covered include: human-computer interface software, multimode fiber optic communication links, electrochemical impedance spectroscopy, rocket-triggered lightning, robotics, a flammability study of thin polymeric film materials, a vortex shedding flowmeter, modeling of flow systems, monomethyl hydrazine vapor detection, a rocket noise filter system using digital filters, computer programs, lower body negative pressure, closed ecological systems, and others. Several reports with respect to space shuttle orbiters are presented.

  13. 14 CFR 91.1415 - CAMP: Mechanical reliability reports.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... manager who maintains program aircraft under a CAMP must report the occurrence or detection of each...-dumping system that affects fuel flow or causes hazardous leakage during flight; (12) An unwanted landing...

  14. Perchlorate Contamination of Drinking Water: Regulatory Issues and Legislative Actions

    DTIC Science & Technology

    2005-02-23

    health risks of perchlorate exposures include effects on the developing nervous systems and thyroid tumors, based on rat studies that observed benign...supplies nationwide. The regulation required monitoring by all water systems serving more than 10,000 persons and by a representative sample of smaller... systems . In 2004, EPA reported that perchlorate has been detected in public water systems in 24 states and Puerto Rico.4 The agency also reported

  15. ISS-An Electronic Syndromic Surveillance System for Infectious Disease in Rural China

    PubMed Central

    Yan, Weirong; Palm, Lars; Lu, Xin; Nie, Shaofa; Xu, Biao; Zhao, Qi; Tao, Tao; Cheng, Liwei; Tan, Li; Dong, Hengjin; Diwan, Vinod K.

    2013-01-01

    Background syndromic surveillance system has great advantages in promoting the early detection of epidemics and reducing the necessities of disease confirmation, and it is especially effective for surveillance in resource poor settings. However, most current syndromic surveillance systems are established in developed countries, and there are very few reports on the development of an electronic syndromic surveillance system in resource-constrained settings. Objective this study describes the design and pilot implementation of an electronic surveillance system (ISS) for the early detection of infectious disease epidemics in rural China, complementing the conventional case report surveillance system. Methods ISS was developed based on an existing platform ‘Crisis Information Sharing Platform’ (CRISP), combining with modern communication and GIS technology. ISS has four interconnected functions: 1) work group and communication group; 2) data source and collection; 3) data visualization; and 4) outbreak detection and alerting. Results As of Jan. 31st 2012, ISS has been installed and pilot tested for six months in four counties in rural China. 95 health facilities, 14 pharmacies and 24 primary schools participated in the pilot study, entering respectively 74256, 79701, and 2330 daily records into the central database. More than 90% of surveillance units at the study sites are able to send daily information into the system. In the paper, we also presented the pilot data from health facilities in the two counties, which showed the ISS system had the potential to identify the change of disease patterns at the community level. Conclusions The ISS platform may facilitate the early detection of infectious disease epidemic as it provides near real-time syndromic data collection, interactive visualization, and automated aberration detection. However, several constraints and challenges were encountered during the pilot implementation of ISS in rural China. PMID:23626853

  16. ISS--an electronic syndromic surveillance system for infectious disease in rural China.

    PubMed

    Yan, Weirong; Palm, Lars; Lu, Xin; Nie, Shaofa; Xu, Biao; Zhao, Qi; Tao, Tao; Cheng, Liwei; Tan, Li; Dong, Hengjin; Diwan, Vinod K

    2013-01-01

    Syndromic surveillance system has great advantages in promoting the early detection of epidemics and reducing the necessities of disease confirmation, and it is especially effective for surveillance in resource poor settings. However, most current syndromic surveillance systems are established in developed countries, and there are very few reports on the development of an electronic syndromic surveillance system in resource-constrained settings. This study describes the design and pilot implementation of an electronic surveillance system (ISS) for the early detection of infectious disease epidemics in rural China, complementing the conventional case report surveillance system. ISS was developed based on an existing platform 'Crisis Information Sharing Platform' (CRISP), combining with modern communication and GIS technology. ISS has four interconnected functions: 1) work group and communication group; 2) data source and collection; 3) data visualization; and 4) outbreak detection and alerting. As of Jan. 31(st) 2012, ISS has been installed and pilot tested for six months in four counties in rural China. 95 health facilities, 14 pharmacies and 24 primary schools participated in the pilot study, entering respectively 74,256, 79,701, and 2330 daily records into the central database. More than 90% of surveillance units at the study sites are able to send daily information into the system. In the paper, we also presented the pilot data from health facilities in the two counties, which showed the ISS system had the potential to identify the change of disease patterns at the community level. The ISS platform may facilitate the early detection of infectious disease epidemic as it provides near real-time syndromic data collection, interactive visualization, and automated aberration detection. However, several constraints and challenges were encountered during the pilot implementation of ISS in rural China.

  17. Highly sensitive detection of naphthalene in solvent vapor using a functionalized PBG refractive index sensor.

    PubMed

    Girschikofsky, Maiko; Rosenberger, Manuel; Belle, Stefan; Brutschy, Malte; Waldvogel, Siegfried R; Hellmann, Ralf

    2012-01-01

    We report an optical refractive index sensor system based on a planar Bragg grating which is functionalized by substituted γ-cyclodextrin to determine low concentrations of naphthalene in solvent vapor. The sensor system exhibits a quasi-instantaneous shift of the Bragg wavelength and is therefore capable for online detection. The overall shift of the Bragg wavelength reveals a linear relationship to the analyte concentration with a gradient of 12.5 ± 1.5 pm/ppm. Due to the spectral resolution and repeatability of the interrogation system, this corresponds to acquisition steps of 80 ppb. Taking into account the experimentally detected signal noise a minimum detection limit of 0.48 ± 0.05 ppm is deduced.

  18. Detection and assessment of secondary sonic booms in New England

    DOT National Transportation Integrated Search

    1980-05-01

    This report documents the results of a secondary sonic boom detection and assessment program conducted by the U.S. Dept. of Transportation, Transportation Systems Center in New England during the summer of 1979. Measurements of both acoustic and infr...

  19. Next-Generation Botnet Detection and Response

    DTIC Science & Technology

    2008-06-24

    REPORT Final Report of "Next-Generation Botnet Detection and Response" 14. ABSTRACT 16. SECURITY CLASSIFICATION OF: In this project, we developed...and Wenke Lee. ?In Proceedings of The 13th Annual Network and Distributed System Security Symposium (NDSS 2006), San Diego, CA, February 2006. 2...In Proceedings of The 16th USENIX Security Symposium ( Security 󈧋), Boston, MA, August 2007. 3. A Taxonomy of Botnet Structures. ?David Dagon, Guofei

  20. Detection of Protein Interactions in T3S Systems Using Yeast Two-Hybrid Analysis.

    PubMed

    Nilles, Matthew L

    2017-01-01

    Two-hybrid systems, sometimes termed interaction traps, are genetic systems designed to find and analyze interactions between proteins. The most common systems are yeast based (commonly Saccharomyces cerevisae) and rely on the functional reconstitution of the GAL4 transcriptional activator. Reporter genes, such as the lacZ gene of Escherichia coli (encodes β-galactosidase), are placed under GAL4-dependent transcriptional control to provide quick and reliable detection of protein interactions. In this method the use of a yeast-based two-hybrid system is described to study protein interactions between components of type III secretion systems.

  1. 75 FR 75059 - Mandatory Reporting of Greenhouse Gases: Injection and Geologic Sequestration of Carbon Dioxide

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-01

    ... monitoring will achieve detection and quantification of CO 2 in the event surface leakage occurs. The UIC... leakage detection monitoring system or technical specifications should also be described in the MRV plan... of injected CO 2 or from another cause (e.g. natural variability). The MRV plan leakage detection and...

  2. An airborne laser fluorosensor for the detection of oil on water

    NASA Technical Reports Server (NTRS)

    Kim, H. H.; Hickman, G. D.

    1973-01-01

    The successful operation of an airborne laser fluorosensor system is reported that makes it possible to detect and map surface oil, either of natural-seepage or spill origin, on large bodies of water. Preliminary results indicate that the sensitivity of the instrument exceeds that of conventional passive remote sensors currently available for oil spill detection.

  3. X-ray Jets in the CH Cyg Symbiotic System

    NASA Astrophysics Data System (ADS)

    Karovska, Margarita; Gaetz, T.; Lee, N.; Raymond, J.; Hack, W.; Carilli, C.

    2009-09-01

    Symbiotic binaries are interacting systems in which a compact stellar source accretes matter from the wind of the cool evolved companion. There are a few hundred symbiotic systems known today, but jet activity has been detected in only a few of them, including in CH Cyg. CH Cyg is a symbiotic system that has shown significant activity since the mid 1960s. Jets have been detected in optical and radio since 1984, and more recently in 2001 in X-rays using Chandra observations.In 2008 we carried out coordinated multi-wavelength observations of the CH Cyg system with Chandra, HST, and the VLA, in order to study the propagation and interaction with the circumbinary medium of the jet detected in 2001. We report here on the detection of the 2001 SE jet which has expanded in seven years from ˜350AU to ˜1400 AU. The apex of the loop delineating the region of interaction with the circumbinary matter is moving with a speed of ˜700 km/s. Assuming a linear expansion, the jet was launched during the 1999-2000 active phase. We also report on a detection of a powerful new jet in the SW direction, observed in X-ray, optical and radio wavelengths. The new jet has a multi-component structure including an inner jet and counter jet, and a SW component ending in several clumps extending up to a distance of about 750AU.

  4. Automatic detection of pelvic lymph nodes using multiple MR sequences

    NASA Astrophysics Data System (ADS)

    Yan, Michelle; Lu, Yue; Lu, Renzhi; Requardt, Martin; Moeller, Thomas; Takahashi, Satoru; Barentsz, Jelle

    2007-03-01

    A system for automatic detection of pelvic lymph nodes is developed by incorporating complementary information extracted from multiple MR sequences. A single MR sequence lacks sufficient diagnostic information for lymph node localization and staging. Correct diagnosis often requires input from multiple complementary sequences which makes manual detection of lymph nodes very labor intensive. Small lymph nodes are often missed even by highly-trained radiologists. The proposed system is aimed at assisting radiologists in finding lymph nodes faster and more accurately. To the best of our knowledge, this is the first such system reported in the literature. A 3-dimensional (3D) MR angiography (MRA) image is employed for extracting blood vessels that serve as a guide in searching for pelvic lymph nodes. Segmentation, shape and location analysis of potential lymph nodes are then performed using a high resolution 3D T1-weighted VIBE (T1-vibe) MR sequence acquired by Siemens 3T scanner. An optional contrast-agent enhanced MR image, such as post ferumoxtran-10 T2*-weighted MEDIC sequence, can also be incorporated to further improve detection accuracy of malignant nodes. The system outputs a list of potential lymph node locations that are overlaid onto the corresponding MR sequences and presents them to users with associated confidence levels as well as their sizes and lengths in each axis. Preliminary studies demonstrates the feasibility of automatic lymph node detection and scenarios in which this system may be used to assist radiologists in diagnosis and reporting.

  5. Information Assurance Technology Analysis Center Information Assurance Tools Report Intrusion Detection

    DTIC Science & Technology

    1998-01-01

    such as central processing unit (CPU) usage, disk input/output (I/O), memory usage, user activity, and number of logins attempted. The statistics... EMERALD Commercial anomaly detection, system monitoring SRI porras@csl.sri.com www.csl.sri.com/ emerald /index. html Gabriel Commercial system...sensors, it starts to protect the network with minimal configuration and maximum intelligence. T 11 EMERALD TITLE EMERALD (Event Monitoring

  6. Motion-Based Immunological Detection of Zika Virus Using Pt-Nanomotors and a Cellphone.

    PubMed

    Draz, Mohamed Shehata; Lakshminaraasimulu, Nivethitha Kota; Krishnakumar, Sanchana; Battalapalli, Dheerendranath; Vasan, Anish; Kanakasabapathy, Manoj Kumar; Sreeram, Aparna; Kallakuri, Shantanu; Thirumalaraju, Prudhvi; Li, Yudong; Hua, Stephane; Yu, Xu G; Kuritzkes, Daniel R; Shafiee, Hadi

    2018-05-16

    Zika virus (ZIKV) infection is an emerging pandemic threat to humans that can be fatal in newborns. Advances in digital health systems and nanoparticles can facilitate the development of sensitive and portable detection technologies for timely management of emerging viral infections. Here we report a nanomotor-based bead-motion cellphone (NBC) system for the immunological detection of ZIKV. The presence of virus in a testing sample results in the accumulation of platinum (Pt)-nanomotors on the surface of beads, causing their motion in H 2 O 2 solution. Then the virus concentration is detected in correlation with the change in beads motion. The developed NBC system was capable of detecting ZIKV in samples with virus concentrations as low as 1 particle/μL. The NBC system allowed a highly specific detection of ZIKV in the presence of the closely related dengue virus and other neurotropic viruses, such as herpes simplex virus type 1 and human cytomegalovirus. The NBC platform technology has the potential to be used in the development of point-of-care diagnostics for pathogen detection and disease management in developed and developing countries.

  7. Integrated multisensor perimeter detection systems

    NASA Astrophysics Data System (ADS)

    Kent, P. J.; Fretwell, P.; Barrett, D. J.; Faulkner, D. A.

    2007-10-01

    The report describes the results of a multi-year programme of research aimed at the development of an integrated multi-sensor perimeter detection system capable of being deployed at an operational site. The research was driven by end user requirements in protective security, particularly in threat detection and assessment, where effective capability was either not available or prohibitively expensive. Novel video analytics have been designed to provide robust detection of pedestrians in clutter while new radar detection and tracking algorithms provide wide area day/night surveillance. A modular integrated architecture based on commercially available components has been developed. A graphical user interface allows intuitive interaction and visualisation with the sensors. The fusion of video, radar and other sensor data provides the basis of a threat detection capability for real life conditions. The system was designed to be modular and extendable in order to accommodate future and legacy surveillance sensors. The current sensor mix includes stereoscopic video cameras, mmWave ground movement radar, CCTV and a commercially available perimeter detection cable. The paper outlines the development of the system and describes the lessons learnt after deployment in a pilot trial.

  8. Getting the right blood to the right patient: the contribution of near-miss event reporting and barrier analysis.

    PubMed

    Kaplan, H S

    2005-11-01

    Safety and reliability in blood transfusion are not static, but are dynamic non-events. Since performance deviations continually occur in complex systems, their detection and correction must be accomplished over and over again. Non-conformance must be detected early enough to allow for recovery or mitigation. Near-miss events afford early detection of possible system weaknesses and provide an early chance at correction. National event reporting systems, both voluntary and involuntary, have begun to include near-miss reporting in their classification schemes, raising awareness for their detection. MERS-TM is a voluntary safety reporting initiative in transfusion. Currently 22 hospitals submit reports anonymously to a central database which supports analysis of a hospital's own data and that of an aggregate database. The system encourages reporting of near-miss events, where the patient is protected from receiving an unsuitable or incorrect blood component due to a planned or unplanned recovery step. MERS-TM data suggest approximately 90% of events are near-misses, with 10% caught after issue but before transfusion. Near-miss reporting may increase total reports ten-fold. The ratio of near-misses to events with harm is 339:1, consistent with other industries' ratio of 300:1, which has been proposed as a measure of reporting in event reporting systems. Use of a risk matrix and an event's relation to protective barriers allow prioritization of these events. Near-misses recovered by planned barriers occur ten times more frequently then unplanned recoveries. A bedside check of the patient's identity with that on the blood component is an essential, final barrier. How the typical two person check is performed, is critical. Even properly done, this check is ineffective against sampling and testing errors. Blood testing at bedside just prior to transfusion minimizes the risk of such upstream events. However, even with simple and well designed devices, training may be a critical issue. Sample errors account for more than half of reported events. The most dangerous miscollection is a blood sample passing acceptance with no previous patient results for comparison. Bar code labels or collection of a second sample may counter this upstream vulnerability. Further upstream barriers have been proposed to counter the precariousness of urgent blood sample collection in a changing unstable situation. One, a linking device, allows safer labeling of tubes away from the bedside, the second, a forcing function, prevents omission of critical patient identification steps. Errors in the blood bank itself account for 15% of errors with a high potential severity. In one such event, a component incorrectly issued, but safely detected prior to transfusion, focused attention on multitasking's contribution to laboratory error. In sum, use of near-miss information, by enhancing barriers supporting error prevention and mitigation, increases our capacity to get the right blood to the right patient.

  9. Real-time exhaust gas modular flowmeter and emissions reporting system for mobile apparatus

    NASA Technical Reports Server (NTRS)

    Breton, Leo Alphonse Gerard (Inventor)

    2002-01-01

    A real-time emissions reporting system includes an instrument module adapted to be detachably connected to the exhaust pipe of a combustion engine to provide for flow of exhaust gas therethrough. The instrument module includes a differential pressure probe which allows for determination of flow rate of the exhaust gas and a gas sampling tube for continuously feeding a sample of the exhaust gas to a gas analyzer or a mounting location for a non-sampling gas analyzer. In addition to the module, the emissions reporting system also includes an elastomeric boot for detachably connecting the module to the exhaust pipe of the combustion engine, a gas analyzer for receiving and analyzing gases sampled within the module and a computer for calculating pollutant mass flow rates based on concentrations detected by the gas analyzer and the detected flowrate of the exhaust gas. The system may also include a particulate matter detector with a second gas sampling tube feeding same mounted within the instrument module.

  10. Design of intelligent proximity detection zones to prevent striking and pinning fatalities around continuous mining machines.

    PubMed

    Bissert, P T; Carr, J L; DuCarme, J P; Smith, A K

    2016-01-01

    The continuous mining machine is a key piece of equipment used in underground coal mining operations. Over the past several decades these machines have been involved in a number of mine worker fatalities. Proximity detection systems have been developed to avert hazards associated with operating continuous mining machines. Incorporating intelligent design into proximity detection systems allows workers greater freedom to position themselves to see visual cues or avoid other hazards such as haulage equipment or unsupported roof or ribs. However, intelligent systems must be as safe as conventional proximity detection systems. An evaluation of the 39 fatal accidents for which the Mine Safety and Health Administration has published fatality investigation reports was conducted to determine whether the accident may have been prevented by conventional or intelligent proximity. Multiple zone configurations for the intelligent systems were studied to determine how system performance might be affected by the zone configuration. Researchers found that 32 of the 39 fatalities, or 82 percent, may have been prevented by both conventional and intelligent proximity systems. These results indicate that, by properly configuring the zones of an intelligent proximity detection system, equivalent protection to a conventional system is possible.

  11. Integrated active sensor system for real time vibration monitoring.

    PubMed

    Liang, Qijie; Yan, Xiaoqin; Liao, Xinqin; Cao, Shiyao; Lu, Shengnan; Zheng, Xin; Zhang, Yue

    2015-11-05

    We report a self-powered, lightweight and cost-effective active sensor system for vibration monitoring with multiplexed operation based on contact electrification between sensor and detected objects. The as-fabricated sensor matrix is capable of monitoring and mapping the vibration state of large amounts of units. The monitoring contents include: on-off state, vibration frequency and vibration amplitude of each unit. The active sensor system delivers a detection range of 0-60 Hz, high accuracy (relative error below 0.42%), long-term stability (10000 cycles). On the time dimension, the sensor can provide the vibration process memory by recording the outputs of the sensor system in an extend period of time. Besides, the developed sensor system can realize detection under contact mode and non-contact mode. Its high performance is not sensitive to the shape or the conductivity of the detected object. With these features, the active sensor system has great potential in automatic control, remote operation, surveillance and security systems.

  12. Integrated active sensor system for real time vibration monitoring

    PubMed Central

    Liang, Qijie; Yan, Xiaoqin; Liao, Xinqin; Cao, Shiyao; Lu, Shengnan; Zheng, Xin; Zhang, Yue

    2015-01-01

    We report a self-powered, lightweight and cost-effective active sensor system for vibration monitoring with multiplexed operation based on contact electrification between sensor and detected objects. The as-fabricated sensor matrix is capable of monitoring and mapping the vibration state of large amounts of units. The monitoring contents include: on-off state, vibration frequency and vibration amplitude of each unit. The active sensor system delivers a detection range of 0–60 Hz, high accuracy (relative error below 0.42%), long-term stability (10000 cycles). On the time dimension, the sensor can provide the vibration process memory by recording the outputs of the sensor system in an extend period of time. Besides, the developed sensor system can realize detection under contact mode and non-contact mode. Its high performance is not sensitive to the shape or the conductivity of the detected object. With these features, the active sensor system has great potential in automatic control, remote operation, surveillance and security systems. PMID:26538293

  13. Design and evaluation of the ReKon : an integrated detection and assessment perimeter system.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dabling, Jeffrey Glenn; Andersen, Jason Jann; McLaughlin, James O.

    2013-02-01

    Kontek Industries (Kannapolis, NC) and their subsidiary, Stonewater Control Systems (Kannapolis, NC), have entered into a cooperative research and development agreement with Sandia to jointly develop and evaluate an integrated perimeter security system solution, one that couples access delay with detection and assessment. This novel perimeter solution was designed to be configurable for use at facilities ranging from high-security military sites to commercial power plants, to petro/chemical facilities of various kinds. A prototype section of the perimeter has been produced and installed at the Sandia Test and Evaluation Center in Albuquerque, NM. This prototype system integrated fiber optic break sensors,more » active infrared sensors, fence disturbance sensors, video motion detection, and ground sensors. This report documents the design, testing, and performance evaluation of the developed ReKon system. The ability of the system to properly detect pedestrian or vehicle attempts to bypass, breach, or otherwise defeat the system is characterized, as well as the Nuisance Alarm Rate.« less

  14. Reference set for performance testing of pediatric vaccine safety signal detection methods and systems.

    PubMed

    Brauchli Pernus, Yolanda; Nan, Cassandra; Verstraeten, Thomas; Pedenko, Mariia; Osokogu, Osemeke U; Weibel, Daniel; Sturkenboom, Miriam; Bonhoeffer, Jan

    2016-12-12

    Safety signal detection in spontaneous reporting system databases and electronic healthcare records is key to detection of previously unknown adverse events following immunization. Various statistical methods for signal detection in these different datasources have been developed, however none are geared to the pediatric population and none specifically to vaccines. A reference set comprising pediatric vaccine-adverse event pairs is required for reliable performance testing of statistical methods within and across data sources. The study was conducted within the context of the Global Research in Paediatrics (GRiP) project, as part of the seventh framework programme (FP7) of the European Commission. Criteria for the selection of vaccines considered in the reference set were routine and global use in the pediatric population. Adverse events were primarily selected based on importance. Outcome based systematic literature searches were performed for all identified vaccine-adverse event pairs and complemented by expert committee reports, evidence based decision support systems (e.g. Micromedex), and summaries of product characteristics. Classification into positive (PC) and negative control (NC) pairs was performed by two independent reviewers according to a pre-defined algorithm and discussed for consensus in case of disagreement. We selected 13 vaccines and 14 adverse events to be included in the reference set. From a total of 182 vaccine-adverse event pairs, we classified 18 as PC, 113 as NC and 51 as unclassifiable. Most classifications (91) were based on literature review, 45 were based on expert committee reports, and for 46 vaccine-adverse event pairs, an underlying pathomechanism was not plausible classifying the association as NC. A reference set of vaccine-adverse event pairs was developed. We propose its use for comparing signal detection methods and systems in the pediatric population. Published by Elsevier Ltd.

  15. Patient-Reported Safety Information: A Renaissance of Pharmacovigilance?

    PubMed

    Härmark, Linda; Raine, June; Leufkens, Hubert; Edwards, I Ralph; Moretti, Ugo; Sarinic, Viola Macolic; Kant, Agnes

    2016-10-01

    The role of patients as key contributors in pharmacovigilance was acknowledged in the new EU pharmacovigilance legislation. This contains several efforts to increase the involvement of the general public, including making patient adverse drug reaction (ADR) reporting systems mandatory. Three years have passed since the legislation was introduced and the key question is: does pharmacovigilance yet make optimal use of patient-reported safety information? Independent research has shown beyond doubt that patients make an important contribution to pharmacovigilance signal detection. Patient reports provide first-hand information about the suspected ADR and the circumstances under which it occurred, including medication errors, quality failures, and 'near misses'. Patient-reported safety information leads to a better understanding of the patient's experiences of the ADR. Patients are better at explaining the nature, personal significance and consequences of ADRs than healthcare professionals' reports on similar associations and they give more detailed information regarding quality of life including psychological effects and effects on everyday tasks. Current methods used in pharmacovigilance need to optimise use of the information reported from patients. To make the most of information from patients, the systems we use for collecting, coding and recording patient-reported information and the methodologies applied for signal detection and assessment need to be further developed, such as a patient-specific form, development of a severity grading and evolution of the database structure and the signal detection methods applied. It is time for a renaissance of pharmacovigilance.

  16. Data-mining for detecting signals of adverse drug reactions of fluoxetine using the Korea Adverse Event Reporting System (KAERS) database.

    PubMed

    Kim, Seonji; Park, Kyounghoon; Kim, Mi-Sook; Yang, Bo Ram; Choi, Hyun Jin; Park, Byung-Joo

    2017-10-01

    Selective serotonin reuptake inhibitors (SSRIs) have become one of the most broadly used medications in psychiatry. Fluoxetine is the first representative antidepressant SSRI drug approved by the Food and Drug Administration (FDA) in 1987. Safety information on fluoxetine use alone was less reported than its combined use with other drugs. There were no published papers on adverse drug reactions (ADRs) of fluoxetine analyzing spontaneous adverse events reports. We detected signals of the adverse drug reactions of fluoxetine by data mining using the Korea Adverse Events Reporting System (KAERS) database. We defined signals in this study by the reporting odds ratios (ROR), proportional reporting ratios (PRR), and information components (IC) indices. The KAERS database included 860,224 AE reports, among which 866 reports contained fluoxetine. We compared the labels of fluoxetine among the United States, UK, Germany, France, China, and Korea. Some of the signals, including emotional lability, myositis, spinal stenosis, paradoxical drug reaction, drug dependence, extrapyramidal disorder, adrenal insufficiency, and intracranial hemorrhage, were not labeled in the six countries. In conclusion, we identified new signals that were not known at the time of market approval. However, certain factors should be required for signal evaluation, such as clinical significance, preventability, and causality of the detected signals. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Computerized controlled-substance surveillance: application involving automated storage and distribution cabinets.

    PubMed

    Wellman, G S; Hammond, R L; Talmage, R

    2001-10-01

    A secondary data-reporting system used to scan the archives of a hospital's automated storage and distribution cabinets (ASDCs) for indications of controlled-substance diversion is described. ASDCs, which allow access to multiple doses of the same medication at one time, use drug count verification to ensure complete audits and disposition tracking. Because an ASDC may interpret inappropriate removal of a medication as a normal transaction, users of ASDCs should have a comprehensive plan for detecting and investigating controlled-substance diversion. Monitoring for and detecting diversion can be difficult and time-consuming, given the limited report-generating features of many ASDCs. Managers at an 800-bed hospital used report-writing software to address these problems. This application interfaces with the hospital's computer system and generates customized reports. The monthly activity recapitulation report lists each user of the ASDCs and gives a summary of all the controlled-substance transactions for those users for the time period specified. The monthly summary report provides the backbone of the surveillance system and identifies situations that require further audit and review. This report provides a summary of each user's activity for a specific medication for the time period specified. The detailed summary report allows for efficient review of specific transactions before there is a decision to conduct a chart review. This report identifies all ASDC controlled-substance transactions associated with a user. A computerized report-generating system identifies instances of inappropriate removal of controlled substances from a hospital's ASDCs.

  18. Optical demodulation system for digitally encoded suspension array in fluoroimmunoassay

    NASA Astrophysics Data System (ADS)

    He, Qinghua; Li, Dongmei; He, Yonghong; Guan, Tian; Zhang, Yilong; Shen, Zhiyuan; Chen, Xuejing; Liu, Siyu; Lu, Bangrong; Ji, Yanhong

    2017-09-01

    A laser-induced breakdown spectroscopy and fluorescence spectroscopy-coupled optical system is reported to demodulate digitally encoded suspension array in fluoroimmunoassay. It takes advantage of the plasma emissions of assembled elemental materials to digitally decode the suspension array, providing a more stable and accurate recognition to target biomolecules. By separating the decoding procedure of suspension array and adsorption quantity calculation of biomolecules into two independent channels, the cross talk between decoding and label signals in traditional methods had been successfully avoided, which promoted the accuracy of both processes and realized more sensitive quantitative detection of target biomolecules. We carried a multiplexed detection of several types of anti-IgG to verify the quantitative analysis performance of the system. A limit of detection of 1.48×10-10 M was achieved, demonstrating the detection sensitivity of the optical demodulation system.

  19. Implementation of a model based fault detection and diagnosis for actuation faults of the Space Shuttle main engine

    NASA Technical Reports Server (NTRS)

    Duyar, A.; Guo, T.-H.; Merrill, W.; Musgrave, J.

    1992-01-01

    In a previous study, Guo, Merrill and Duyar, 1990, reported a conceptual development of a fault detection and diagnosis system for actuation faults of the space shuttle main engine. This study, which is a continuation of the previous work, implements the developed fault detection and diagnosis scheme for the real time actuation fault diagnosis of the space shuttle main engine. The scheme will be used as an integral part of an intelligent control system demonstration experiment at NASA Lewis. The diagnosis system utilizes a model based method with real time identification and hypothesis testing for actuation, sensor, and performance degradation faults.

  20. Final report : mobile surveillance and wireless communication systems field operational test. Volume 2, FOT objectives, organization, system design, results, conclusions, and recommendations

    DOT National Transportation Integrated Search

    1999-03-01

    The Mobile Surveillance and Wireless Communication Systems Field Operational Test (FOT) evaluated the performance of wireless traffic detection and communications systems in areas where permanent detectors, electrical power, and landline communicatio...

  1. Detection of Obstacles in Monocular Image Sequences

    NASA Technical Reports Server (NTRS)

    Kasturi, Rangachar; Camps, Octavia

    1997-01-01

    The ability to detect and locate runways/taxiways and obstacles in images captured using on-board sensors is an essential first step in the automation of low-altitude flight, landing, takeoff, and taxiing phase of aircraft navigation. Automation of these functions under different weather and lighting situations, can be facilitated by using sensors of different modalities. An aircraft-based Synthetic Vision System (SVS), with sensors of different modalities mounted on-board, complements the current ground-based systems in functions such as detection and prevention of potential runway collisions, airport surface navigation, and landing and takeoff in all weather conditions. In this report, we address the problem of detection of objects in monocular image sequences obtained from two types of sensors, a Passive Millimeter Wave (PMMW) sensor and a video camera mounted on-board a landing aircraft. Since the sensors differ in their spatial resolution, and the quality of the images obtained using these sensors is not the same, different approaches are used for detecting obstacles depending on the sensor type. These approaches are described separately in two parts of this report. The goal of the first part of the report is to develop a method for detecting runways/taxiways and objects on the runway in a sequence of images obtained from a moving PMMW sensor. Since the sensor resolution is low and the image quality is very poor, we propose a model-based approach for detecting runways/taxiways. We use the approximate runway model and the position information of the camera provided by the Global Positioning System (GPS) to define regions of interest in the image plane to search for the image features corresponding to the runway markers. Once the runway region is identified, we use histogram-based thresholding to detect obstacles on the runway and regions outside the runway. This algorithm is tested using image sequences simulated from a single real PMMW image.

  2. Photon-number-resolving SSPDs with system detection efficiency over 50% at telecom range

    NASA Astrophysics Data System (ADS)

    Zolotov, P.; Divochiy, A.; Vakhtomin, Yu.; Moshkova, M.; Morozov, P.; Seleznev, V.; Smirnov, K.

    2018-02-01

    We used technology of making high-efficiency superconducting single-photon detectors as a basis for improvement of photon-number-resolving devices. By adding optical cavity and using an improved NbN superconducting film, we enhanced previously reported system detection efficiency at telecom range for such detectors. Our results show that implementation of optical cavity helps to develop four-section device with quantum efficiency over 50% at 1.55 µm. Performed experimental studies of detecting multi-photon optical pulses showed irregularities over defining multi-photon through single-photon quantum efficiency.

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bartoletti, T.

    SPI/U3.1 consists of five tools used to assess and report the security posture of computers running the UNIX operating system. The tools are: Access Control Test: A rule-based system which identifies sequential dependencies in UNIX access controls. Binary Inspector Tool: Evaluates the release status of system binaries by comparing a crypto-checksum to provide table entries. Change Detection Tool: Maintains and applies a snapshot of critical system files and attributes for purposes of change detection. Configuration Query Language: Accepts CQL-based scripts (provided) to evaluate queries over the status of system files, configuration of services and many other elements of UNIX systemmore » security. Password Security Inspector: Tests for weak or aged passwords. The tools are packaged with a forms-based user interface providing on-line context-sensistive help, job scheduling, parameter management and output report management utilities. Tools may be run independent of the UI.« less

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bartoletti, Tony

    SPI/U3.2 consists of five tools used to assess and report the security posture of computers running the UNIX operating system. The tools are: Access Control Test: A rule-based system which identifies sequential dependencies in UNIX access controls. Binary Authentication Tool: Evaluates the release status of system binaries by comparing a crypto-checksum to provide table entries. Change Detection Tool: Maintains and applies a snapshot of critical system files and attributes for purposes of change detection. Configuration Query Language: Accepts CQL-based scripts (provided) to evaluate queries over the status of system files, configuration of services and many other elements of UNIX systemmore » security. Password Security Inspector: Tests for weak or aged passwords. The tools are packaged with a forms-based user interface providing on-line context-sensistive help, job scheduling, parameter management and output report management utilities. Tools may be run independent of the UI.« less

  5. A single step reversed-phase high performance liquid chromatography separation of polar and non-polar lipids.

    PubMed

    Olsson, Petter; Holmbäck, Jan; Herslöf, Bengt

    2014-11-21

    This paper reports a simple chromatographic system to separate lipids classes as well as their molecular species. By the use of phenyl coated silica as stationary phase in combination with a simple mobile phase consisting of methanol and water, all tested lipid classes elute within 30 min. Furthermore, a method to accurately predict retention times of specific lipid components for this type of chromatography is presented. Common detection systems were used, namely evaporative light scattering detection (ELSD), charged aerosol detection (CAD), electrospray mass spectrometry (ESI-MS), and UV detection. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. Association rule mining in the US Vaccine Adverse Event Reporting System (VAERS).

    PubMed

    Wei, Lai; Scott, John

    2015-09-01

    Spontaneous adverse event reporting systems are critical tools for monitoring the safety of licensed medical products. Commonly used signal detection algorithms identify disproportionate product-adverse event pairs and may not be sensitive to more complex potential signals. We sought to develop a computationally tractable multivariate data-mining approach to identify product-multiple adverse event associations. We describe an application of stepwise association rule mining (Step-ARM) to detect potential vaccine-symptom group associations in the US Vaccine Adverse Event Reporting System. Step-ARM identifies strong associations between one vaccine and one or more adverse events. To reduce the number of redundant association rules found by Step-ARM, we also propose a clustering method for the post-processing of association rules. In sample applications to a trivalent intradermal inactivated influenza virus vaccine and to measles, mumps, rubella, and varicella (MMRV) vaccine and in simulation studies, we find that Step-ARM can detect a variety of medically coherent potential vaccine-symptom group signals efficiently. In the MMRV example, Step-ARM appears to outperform univariate methods in detecting a known safety signal. Our approach is sensitive to potentially complex signals, which may be particularly important when monitoring novel medical countermeasure products such as pandemic influenza vaccines. The post-processing clustering algorithm improves the applicability of the approach as a screening method to identify patterns that may merit further investigation. Copyright © 2015 John Wiley & Sons, Ltd.

  7. Development of a computerized monitoring program to identify narcotic diversion in a pediatric anesthesia practice.

    PubMed

    Brenn, B Randall; Kim, Margaret A; Hilmas, Elora

    2015-08-15

    Development of an operational reporting dashboard designed to correlate data from multiple sources to help detect potential drug diversion by automated dispensing cabinet (ADC) users is described. A commercial business intelligence platform was used to create a dashboard tool for rapid detection of unusual patterns of ADC transactions by anesthesia service providers at a large pediatric hospital. By linking information from the hospital's pharmacy information management system (PIMS) and anesthesia information management system (AIMS) in an associative data model, the "narcotic reconciliation dashboard" can generate various reports to help spot outlier activity associated with ADC dispensing of controlled substances and documentation of medication waste processing. The dashboard's utility was evaluated by "back-testing" the program with historical data on an actual episode of diversion by an anesthesia provider that had not been detected through traditional methods of PIMS and AIMS data monitoring. Dashboard-generated reports on key metrics (e.g., ADC transaction counts, discrepancies in dispensed versus reconciled amounts of narcotics, PIMS-AIMS documentation mismatches) over various time frames during the period of known diversion clearly indicated the diverter's outlier status relative to other authorized ADC users. A dashboard program for correlating ADC transaction data with pharmacy and patient care data may be an effective tool for detecting patterns of ADC use that suggest drug diversion. Copyright © 2015 by the American Society of Health-System Pharmacists, Inc. All rights reserved.

  8. Effects of Wearing NBC (Nuclear, Biological and Chemical) Protective Clothing in the Heat on Detection of Visual Signals

    DTIC Science & Technology

    1985-02-01

    agents, as well as nuclear weaponry. In the face of’ such threats, the United States Army has developed equinment and clothing systems designed to...AD_ REPORT NO. T7185 EFFECTS OF WEARING NBC PROTECTIVE CLOTHING IN THE HEAT ON DETECTION OF VISUAL SIGNALS U S ARMY RESEARCH INSTITUTE N OF...CATALOG NUMBER T7/•5 ( 4. TITLE (and Subtitle) 5. TYPE OF REPORT & PERIOD COVERED Effects of Wearing NBC Protective Clothing in the Technical Report Heat

  9. Phenotyping for patient safety: algorithm development for electronic health record based automated adverse event and medical error detection in neonatal intensive care.

    PubMed

    Li, Qi; Melton, Kristin; Lingren, Todd; Kirkendall, Eric S; Hall, Eric; Zhai, Haijun; Ni, Yizhao; Kaiser, Megan; Stoutenborough, Laura; Solti, Imre

    2014-01-01

    Although electronic health records (EHRs) have the potential to provide a foundation for quality and safety algorithms, few studies have measured their impact on automated adverse event (AE) and medical error (ME) detection within the neonatal intensive care unit (NICU) environment. This paper presents two phenotyping AE and ME detection algorithms (ie, IV infiltrations, narcotic medication oversedation and dosing errors) and describes manual annotation of airway management and medication/fluid AEs from NICU EHRs. From 753 NICU patient EHRs from 2011, we developed two automatic AE/ME detection algorithms, and manually annotated 11 classes of AEs in 3263 clinical notes. Performance of the automatic AE/ME detection algorithms was compared to trigger tool and voluntary incident reporting results. AEs in clinical notes were double annotated and consensus achieved under neonatologist supervision. Sensitivity, positive predictive value (PPV), and specificity are reported. Twelve severe IV infiltrates were detected. The algorithm identified one more infiltrate than the trigger tool and eight more than incident reporting. One narcotic oversedation was detected demonstrating 100% agreement with the trigger tool. Additionally, 17 narcotic medication MEs were detected, an increase of 16 cases over voluntary incident reporting. Automated AE/ME detection algorithms provide higher sensitivity and PPV than currently used trigger tools or voluntary incident-reporting systems, including identification of potential dosing and frequency errors that current methods are unequipped to detect. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  10. A molecular rotor based ratiometric sensor for basic amino acids.

    PubMed

    Pettiwala, Aafrin M; Singh, Prabhat K

    2018-01-05

    The inevitable importance of basic amino acids, arginine and lysine, in human health and metabolism demands construction of efficient sensor systems for them. However, there are only limited reports on the 'ratiometric' detection of basic amino acids which is further restricted by the use of chemically complex sensor molecules, which impedes their prospect for practical applications. Herein, we report a ratiometric sensor system build on simple mechanism of disassociation of novel emissive Thioflavin-T H-aggregates from heparin surface, when subjected to interaction with basic amino acids. The strong and selective electrostatic and hydrogen bonding interaction of basic amino acids with heparin leads to large alteration in photophysical attributes of heparin bound Thioflavin-T, which forms a highly sensitive sensor platform for detection of basic amino acids in aqueous solution. These selective interactions between basic amino acids and heparin allow our sensor system to discriminate arginine and lysine from other amino acids. This unique mechanism of dissociation of Thioflavin-T aggregates from heparin surface provides ratiometric response on both fluorimetric and colorimetric outputs for detection of arginine and lysine, and thus it holds a significant advantage over other developed sensor systems which are restricted to single wavelength detection. Apart from the sensitivity and selectivity, our system also provides the advantage of simplicity, dual mode of sensing, and more importantly, it employs an inexpensive commercially available probe molecule, which is a significant advantage over other developed sensor systems that uses tedious synthesis protocol for the employed probe in the detection scheme, an impediment for practical applications. Additionally, our sensor system also shows response in complex biological media of serum samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Methods, microfluidic devices, and systems for detection of an active enzymatic agent

    DOEpatents

    Sommer, Gregory J; Hatch, Anson V; Singh, Anup K; Wang, Ying-Chih

    2014-10-28

    Embodiments of the present invention provide methods, microfluidic devices, and systems for the detection of an active target agent in a fluid sample. A substrate molecule is used that contains a sequence which may cleave in the presence of an active target agent. A SNAP25 sequence is described, for example, that may be cleaved in the presence of Botulinum Neurotoxin. The substrate molecule includes a reporter moiety. The substrate molecule is exposed to the sample, and resulting reaction products separated using electrophoretic separation. The elution time of the reporter moiety may be utilized to identify the presence or absence of the active target agent.

  12. Development of a microwave clothes dryer: Interim report 4. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, R.; Lenz, R.

    1996-03-01

    The objective of the project is to investigate the microwave drying of clothes and to produce data that potential manufacturers can use in developing marketable microwave dryers. This is an interim report covering activities in 1994, the fifth year of the project. During 1994, three field test dryers were completed, two residential models and one commercial subscale model. All of these dryers operated at a microwave frequency of 2,450 MHz, which is the frequency of home microwave ovens and ovens used in fastfood outlets. Consequently, magnetron tubes for these high-production items are inexpensive. The residential dryers were tested according tomore » the Department of Energy protocols and were 15% more efficient than a top-of-the-line conventional electric dryer. They were also 14% faster. Extensive testing was done to assure that the hazard-detection (sniffer) system would sense degradation of the lighter and shut down the dryer before a fire could occur. Numerous butane lighters were heated to destruction in a microwave oven to examine their failure modes. Lighters were placed in microwave dryers equipped with hazard-detection systems; these systems always detected incipient problems before any fire hazard could occur.« less

  13. A model system for pathogen detection using a two-component bacteriophage/bioluminescent signal amplification assay

    NASA Astrophysics Data System (ADS)

    Bright, Nathan G.; Carroll, Richard J.; Applegate, Bruce M.

    2004-03-01

    Microbial contamination has become a mounting concern the last decade due to an increased emphasis of minimally processed food products specifically produce, and the recognition of foodborne pathogens such as Campylobacter jejuni, Escherichia coli O157:H7, and Listeria monocytogenes. This research investigates a detection approach utilizing bacteriophage pathogen specificity coupled with a bacterial bioluminescent bioreporter utilizing the quorum sensing molecule from Vibrio fischeri, N-(3-oxohexanoyl)-homoserine lactone (3-oxo-C6-HSL). The 3-oxo-C6-HSL molecules diffuse out of the target cell after infection and induce bioluminescence from a population of 3-oxo-C6-HSL bioreporters (ROLux). E. coli phage M13, a well-characterized bacteriophage, offers a model system testing the use of bacteriophage for pathogen detection through cell-to-cell communication via a LuxR/3-oxo-C6-HSL system. Simulated temperate phage assays tested functionality of the ROLux reporter and production of 3-oxo-C6-HSL by various test strains. These assays showed detection limits of 102cfu after 24 hours in a varietry of detection formats. Assays incorporating the bacteriophage M13-luxI with the ROLux reporter and a known population of target cells were subsequently developed and have shown consistent detection limits of 105cfu target organisms. Measurable light response from high concentrations of target cells was almost immediate, suggesting an enrichment step to further improve detection limits and reduce assay time.

  14. The Fourier-Kelvin Stellar Interferometer a Low Complexity, Low Cost Space Mission for High-Resolution Astronomy and Direct Exoplanet Detection

    NASA Technical Reports Server (NTRS)

    Barry, R. K.; Danchi, W. C.; Deming, L. D.; Richardson, L. J.; Kuchner, M. J.; Seager, S.; Frey, B. J.; Martino, A. J.; Lee, K. A.; Zuray, M.; hide

    2006-01-01

    The Fourier-Kelvin Stellar Interferometer (FKSI) is a mission concept for a spacecraft-borne nulling interferometer for high-resolution astronomy and the direct detection of exoplanets and assay of their environments and atmospheres. FKSI is a high angular resolution system operating in the near to midinfrared spectral region and is a scientific and technological pathfinder to the Darwin and Terrestrial Planet Finder (TPF) missions. The instrument is configured with an optical system consisting, depending on configuration, of two 0.5 - 1.0 m telescopes on a 12.5 - 20 m boom feeding a symmetric, dual Mach- Zehnder beam combiner. We report on progress on our nulling testbed including the design of an optical pathlength null-tracking control system and development of a testing regime for hollow-core fiber waveguides proposed for use in wavefront cleanup. We also report results of integrated simulation studies of the planet detection performance of FKSI and results from an in-depth control system and residual optical pathlength jitter analysis.

  15. Simple Monitoring of Gene Targeting Efficiency in Human Somatic Cell Lines Using the PIGA Gene

    PubMed Central

    Karnan, Sivasundaram; Konishi, Yuko; Ota, Akinobu; Takahashi, Miyuki; Damdindorj, Lkhagvasuren; Hosokawa, Yoshitaka; Konishi, Hiroyuki

    2012-01-01

    Gene targeting in most of human somatic cell lines has been labor-intensive because of low homologous recombination efficiency. The development of an experimental system that permits a facile evaluation of gene targeting efficiency in human somatic cell lines is the first step towards the improvement of this technology and its application to a broad range of cell lines. In this study, we utilized phosphatidylinositol glycan anchor biosynthesis class A (PIGA), a gene essential for the synthesis of glycosylphosphatidyl inositol (GPI) anchors, as a reporter of gene targeting events in human somatic cell lines. Targeted disruption of PIGA was quantitatively detected with FLAER, a reagent that specifically binds to GPI anchors. Using this PIGA-based reporter system, we successfully detected adeno-associated virus (AAV)-mediated gene targeting events both with and without promoter-trap enrichment of gene-targeted cell population. The PIGA-based reporter system was also capable of reproducing previous findings that an AAV-mediated gene targeting achieves a remarkably higher ratio of homologous versus random integration (H/R ratio) of targeting vectors than a plasmid-mediated gene targeting. The PIGA-based system also detected an approximately 2-fold increase in the H/R ratio achieved by a small negative selection cassette introduced at the end of the AAV-based targeting vector with a promoter-trap system. Thus, our PIGA-based system is useful for monitoring AAV-mediated gene targeting and will assist in improving gene targeting technology in human somatic cell lines. PMID:23056640

  16. High-throughput living cell-based optical biosensor for detection of bacterial lipopolysaccharide (LPS) using a red fluorescent protein reporter system.

    PubMed

    Jiang, Hui; Jiang, Donglei; Shao, Jingdong; Sun, Xiulan; Wang, Jiasheng

    2016-11-14

    Due to the high toxicity of bacterial lipopolysaccharide (LPS), resulting in sepsis and septic shock, two major causes of death worldwide, significant effort is directed toward the development of specific trace-level LPS detection systems. Here, we report sensitive, user-friendly, high-throughput LPS detection in a 96-well microplate using a transcriptional biosensor system, based on 293/hTLR4A-MD2-CD14 cells that are transformed by a red fluorescent protein (mCherry) gene under the transcriptional control of an NF-κB response element. The recognition of LPS activates the biosensor cell, TLR4, and the co-receptor-induced NF-κB signaling pathway, which results in the expression of mCherry fluorescent protein. The novel cell-based biosensor detects LPS with specificity at low concentration. The cell-based biosensor was evaluated by testing LPS isolated from 14 bacteria. Of the tested bacteria, 13 isolated Enterobacteraceous LPSs with hexa-acylated structures were found to increase red fluorescence and one penta-acylated LPS from Pseudomonadaceae appeared less potent. The proposed biosensor has potential for use in the LPS detection in foodstuff and biological products, as well as bacteria identification, assisting the control of foodborne diseases.

  17. Final Report: Fire Prevention, Detection, and Suppression Project, Exploration Technology Development Program

    NASA Technical Reports Server (NTRS)

    Ruff, Gary A.

    2011-01-01

    The Fire Prevention, Detection, and Suppression (FPDS) project is a technology development effort within the Exploration Technology Development Program of the Exploration System Missions Directorate (ESMD) that addresses all aspects of fire safety aboard manned exploration systems. The overarching goal for work in the FPDS area is to develop technologies that will ensure crew health and safety on exploration missions by reducing the likelihood of a fire, or, if one does occur, minimizing the risk to the crew, mission, or system. This is accomplished by addressing the areas of (1) fire prevention and material flammability, (2) fire signatures and detection, and (3) fire suppression and response. This report describes the outcomes of this project from the formation of the Exploration Technology Development Program (ETDP) in October 2005 to September 31, 2010 when the Exploration Technology Development Program was replaced by the Enabling Technology Development and Demonstration Program. NASA s fire safety work will continue under this new program and will build upon the accomplishments described herein.

  18. Turning tryptophanase into odor-generating biosensors.

    PubMed

    Xu, Yaqin; Zhang, Zhuyuan; Ali, M Monsur; Sauder, Joanna; Deng, Xudong; Giang, Karen; Aguirre, Sergio D; Pelton, Robert; Li, Yingfu; Filipe, Carlos D M

    2014-03-03

    An odor-based sensor system that exploits the metabolic enzyme tryptophanase (TPase) as the key component is reported. This enzyme is able to convert an odorless substrate like S-methyl-L-cysteine or L-tryptophan into the odorous products methyl mercaptan or indole. To make a biosensor, TPase was biotinylated so that it could be coupled with a molecular recognition element, such as an antibody, to develop an ELISA-like assay. This method was used for the detection of an antibody present in nM concentrations by the human nose. TPase can also be combined with the enzyme pyridoxal kinase (PKase) for use in a coupled assay to detect adenosine 5'-triphosphate (ATP). When ATP is present in the low μM concentration range, the coupled enzymatic system generates an odor that is easily detectable by the human nose. Biotinylated TPase can be combined with various biotin-labeled molecular recognition elements, thereby enabling a broad range of applications for this odor-based reporting system. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Runway Safety Monitor Algorithm for Single and Crossing Runway Incursion Detection and Alerting

    NASA Technical Reports Server (NTRS)

    Green, David F., Jr.

    2006-01-01

    The Runway Safety Monitor (RSM) is an aircraft based algorithm for runway incursion detection and alerting that was developed in support of NASA's Runway Incursion Prevention System (RIPS) research conducted under the NASA Aviation Safety and Security Program's Synthetic Vision System project. The RSM algorithm provides warnings of runway incursions in sufficient time for pilots to take evasive action and avoid accidents during landings, takeoffs or when taxiing on the runway. The report documents the RSM software and describes in detail how RSM performs runway incursion detection and alerting functions for NASA RIPS. The report also describes the RIPS flight tests conducted at the Reno/Tahoe International Airport (RNO) and the Wallops Flight Facility (WAL) during July and August of 2004, and the RSM performance results and lessons learned from those flight tests.

  20. The use of hospital-based nurses for the surveillance of potential disease outbreaks.

    PubMed Central

    Durrheim, D. N.; Harris, B. N.; Speare, R.; Billinghurst, K.

    2001-01-01

    OBJECTIVE: To study a novel surveillance system introduced in Mpumalanga Province, a rural area in the north-east of South Africa, in an attempt to address deficiencies in the system of notification for infectious conditions that have the potential for causing outbreaks. METHODS: Hospital-based infection control nurses in all of Mpumalanga's 32 public and private hospitals were trained to recognize, report, and respond to nine clinical syndromes that require immediate action. Sustainability of the system was assured through a schedule of regular training and networking, and by providing feedback to the nurses. The system was evaluated by formal review of hospital records, evidence of the effective containment of a cholera outbreak, and assessment of the speed and appropriateness of responses to other syndromes. FINDINGS: Rapid detection, reporting and response to six imported cholera cases resulted in effective containment, with only 19 proven secondary cholera cases, during the two-year review period. No secondary cases followed detection and prompt response to 14 patients with meningococcal disease. By the end of the first year of implementation, all facilities were providing weekly zero-reports on the nine syndromes before the designated time. Formal hospital record review for cases of acute flaccid paralysis endorsed the value of the system. CONCLUSION: The primary goal of an outbreak surveillance system is to ensure timely recognition of syndromes requiring an immediate response. Infection control nurses in Mpumalanga hospitals have excelled in timely weekly zero-reporting, participation at monthly training and feedback sessions, detection of priority clinical syndromes, and prompt appropriate response. This review provides support for the role of hospital-based nurses as valuable sentinel surveillance agents providing timely data for action. PMID:11217663

  1. Lensfree in-line holographic detection of bacteria

    NASA Astrophysics Data System (ADS)

    Poher, V.; Allier, C. P.; Coutard, J. G.; Hervé, L.; Dinten, J. M.

    2011-07-01

    Due to low light scattering, bacteria are difficult to detect using lensless imaging systems. In order to detect individual bacteria, we report a method based on a thin wetting film imaging that produces a micro-lens effect on top of each bacterium when the sample dries up. The imaging using a high-end CMOS sensor is combined with an in-line holographic reconstruction to improve positive detection rate up to 95% with micron-sized beads at high density of ~103 objects/mm2. The system allows detecting from single bacterium to densely packed objects (103 bacteria/μl) within 10μl sample. As an example, E.coli, Bacillus subtilis and Bacillus thuringiensis, has been successfully detected with strong signal to noise ratio across a 24mm2 field of view.

  2. Remote detection of explosives using field asymmetric ion mobility spectrometer installed on multicopter.

    PubMed

    Kostyukevich, Yury; Efremov, Denis; Ionov, Vladimir; Kukaev, Eugene; Nikolaev, Eugene

    2017-11-01

    The detection of explosives and drugs in hard-to-reach places is a considerable challenge. We report the development and initial experimental characterization of the air analysis system that includes Field Asymmetric Ion Mobility Spectrometer, array of the semiconductor gas sensors and is installed on multicopter. The system was developed based on the commercially available DJI Matrix 100 platform. For data collection and communication with operator, the special compact computer (Intel Compute Stick) was installed onboard. The total weight of the system was 3.3 kg. The system allows the 15-minute flight and provides the remote access to the obtained data. The developed system can be effectively used for the detection of impurities in the air, ecology monitoring, detection of chemical warfare agents, and explosives, what is especially important in light of recent terroristic attacks. The capabilities of the system were tested on the several explosives such as trinitrotoluene and nitro powder. Copyright © 2017 John Wiley & Sons, Ltd.

  3. PV Systems Reliability Final Technical Report: Ground Fault Detection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lavrova, Olga; Flicker, Jack David; Johnson, Jay

    We have examined ground faults in PhotoVoltaic (PV) arrays and the efficacy of fuse, current detection (RCD), current sense monitoring/relays (CSM), isolation/insulation (Riso) monitoring, and Ground Fault Detection and Isolation (GFID) using simulations based on a Simulation Program with Integrated Circuit Emphasis SPICE ground fault circuit model, experimental ground faults installed on real arrays, and theoretical equations.

  4. Reagent-free and portable detection of Bacillus anthracis spores using a microfluidic incubator and smartphone microscope

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hutchison, Janine R.; Erikson, Rebecca L.; Sheen, Allison M.

    Rapid, cost-effective bacterial detection systems are needed to respond to potential biothreat events. Here we report the use of smartphone-based microscopy in combination with a simple microfluidic incubation device to detect 5000 Bacillus anthracis spores in 3 hours. This field-deployable approach is compatible with real-time PCR for secondary confirmation.

  5. Detecting, Monitoring, and Reporting Possible Adverse Drug Events Using an Arden-Syntax-based Rule Engine.

    PubMed

    Fehre, Karsten; Plössnig, Manuela; Schuler, Jochen; Hofer-Dückelmann, Christina; Rappelsberger, Andrea; Adlassnig, Klaus-Peter

    2015-01-01

    The detection of adverse drug events (ADEs) is an important aspect of improving patient safety. The iMedication system employs predefined triggers associated with significant events in a patient's clinical data to automatically detect possible ADEs. We defined four clinically relevant conditions: hyperkalemia, hyponatremia, renal failure, and over-anticoagulation. These are some of the most relevant ADEs in internal medical and geriatric wards. For each patient, ADE risk scores for all four situations are calculated, compared against a threshold, and judged to be monitored, or reported. A ward-based cockpit view summarizes the results.

  6. 78 FR 32257 - Privacy Act of 1974; Report of a New Routine Use for Selected CMS Systems of Records

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-29

    ... systems of records to assist in preventing and detecting fraud, waste and abuse. The new routine use will... for the purpose of preventing and detecting fraud, waste and abuse, pursuant to section 1128C(a)(2) of the Social Security Act (``the Act''). At section 1128C(c) of the Act, a health plan is defined as a...

  7. Standardized UXO Technology Demonstration Site Blind Grid Scoring Record No. 764

    DTIC Science & Technology

    2006-04-01

    Attainable accuracy of depth (z) ± 0.3 meter Detection performance for ferrous and nonferrous metals : will detect ammunition components 20-mm...ASSOCIATES, INC. 6832 OLD DOMINION DRIVE MCLEAN, VA 22101 TECHNOLOGY TYPE/PLATFORM: MULTI CHANNEL DETECTOR SYSTEM (AMOS)/TOWED PREPARED BY: U.S...Multi Channel Detector System (AMOS)/Towed, MEC 18. NUMBER OF PAGES 19a. NAME OF RESPONSIBLE PERSON a. REPORT Unclassified b. ABSTRACT

  8. Detection of dechallenge in spontaneous reporting systems: a comparison of Bayes methods.

    PubMed

    Banu, A Bazila; Alias Balamurugan, S Appavu; Thirumalaikolundusubramanian, Ponniah

    2014-01-01

    Dechallenge is a response observed for the reduction or disappearance of adverse drug reactions (ADR) on withdrawal of a drug from a patient. Currently available algorithms to detect dechallenge have limitations. Hence, there is a need to compare available new methods. To detect dechallenge in Spontaneous Reporting Systems, data-mining algorithms like Naive Bayes and Improved Naive Bayes were applied for comparing the performance of the algorithms in terms of accuracy and error. Analyzing the factors of dechallenge like outcome and disease category will help medical practitioners and pharmaceutical industries to determine the reasons for dechallenge in order to take essential steps toward drug safety. Adverse drug reactions of the year 2011 and 2012 were downloaded from the United States Food and Drug Administration's database. The outcome of classification algorithms showed that Improved Naive Bayes algorithm outperformed Naive Bayes with accuracy of 90.11% and error of 9.8% in detecting the dechallenge. Detecting dechallenge for unknown samples are essential for proper prescription. To overcome the issues exposed by Naive Bayes algorithm, Improved Naive Bayes algorithm can be used to detect dechallenge in terms of higher accuracy and minimal error.

  9. Interagency partnering for weed prevention--progress on development of a National Early Detection and Rapid Response System for Invasive Plants in the United States

    USGS Publications Warehouse

    Westbrooks, R.; Westbrooks, R.

    2011-01-01

    Over the past 50 years, experience has shown that interagency groups provide an effective forum for addressing various invasive species issues and challenges on multiple land units. However, more importantly, they can also provide a coordinated framework for early detection, reporting, identification and vouchering, rapid assessment, and rapid response to new and emerging invasive plants in the United States. Interagency collaboration maximizes the use of available expertise, resources, and authority for promoting early detection and rapid response (EDRR) as the preferred management option for addressing new and emerging invasive plants. Currently, an interagency effort is underway to develop a National EDRR System for Invasive Plants in the United States. The proposed system will include structural and informational elements. Structural elements of the system include a network of interagency partner groups to facilitate early detection and rapid response to new invasive plants, including the Federal Interagency Committee for the Management of Noxious and Exotic Weeds (FICMNEW), State Invasive Species Councils, State Early Detection and Rapid Response Coordinating Committees, State Volunteer Detection and Reporting Networks, Invasive Plant Task Forces, and Cooperative Weed Management Areas. Informational elements and products being developed include Regional Invasive Plant Atlases, and EDRR Guidelines for EDRR Volunteer Network Training, Rapid Assessment and Rapid Response, and Criteria for Selection of EDRR Species. System science and technical support elements which are provided by cooperating state and federal scientists, include EDRR guidelines, training curriculum for EDRR volunteers and agency field personnel, plant identification and vouchering, rapid assessments, as well as predictive modeling and ecological range studies for invasive plant species.

  10. NASA Electronic Library System (NELS) optimization

    NASA Technical Reports Server (NTRS)

    Pribyl, William L.

    1993-01-01

    This is a compilation of NELS (NASA Electronic Library System) Optimization progress/problem, interim, and final reports for all phases. The NELS database was examined, particularly in the memory, disk contention, and CPU, to discover bottlenecks. Methods to increase the speed of NELS code were investigated. The tasks included restructuring the existing code to interact with others more effectively. An error reporting code to help detect and remove bugs in the NELS was added. Report writing tools were recommended to integrate with the ASV3 system. The Oracle database management system and tools were to be installed on a Sun workstation, intended for demonstration purposes.

  11. Airborne Windshear Detection and Warning Systems. Fifth and Final Combined Manufacturers' and Technologists' Conference, part 1

    NASA Technical Reports Server (NTRS)

    Delnore, Victor E. (Compiler)

    1994-01-01

    The Fifth (and Final) Combined Manufacturers' and Technologists' Airborne Windshear Review Meeting was hosted jointly by the NASA Langley Research Center (LaRC) and the Federal Aviation Administration (FAA) in Hampton, Virginia, on September 28-30, 1993. The purpose of the meeting was to report on the highly successful windshear experiments conducted by government, academic institutions, and industry; to transfer the results to regulators, manufacturers, and users; and to set initiatives for future aeronautics technology research. The formal sessions covered recent developments in windshear flight testing; windshear modeling, flight management, and ground-based systems; airborne windshear detection systems; certification and regulatory issues; development and applications of sensors for wake vortex detection; and synthetic and enhanced vision systems.

  12. Fibre Optic Mechanical Sensors For Aerospace Applications

    NASA Astrophysics Data System (ADS)

    Batchellor, C. R.; Dakin, J. P.; Pearce, D. A. J.

    1989-04-01

    A fiber optic multisensor methane detection system matched to topology and environment of a coal mine is reported. The system involves time domain multiplexed (TDM) methane sensors based on selective absorption of source radiation by atomic or molecular species in the gas sensing heads. A two-wavelength ratiometric approach allows simple self referencing, cancels out errors arising from other contaminants, and improves the measurement contrast. The laboratory system consists of a high radiance LED source, multimode fiber, optical sensing head, optical bandpass filters, and involves synchronous detection with low noise photodiodes and a lock-in amplifier. Detection sensitivity upon spectral resolution of the optical filters has also been investigated and described. The system performance was evaluated and the results are presented.

  13. Congenital intrahepatic portohepatic venous shunt: treatment with coil embolisation.

    PubMed

    Kim, I O; Cheon, J E; Kim, W S; Chung, J W; Yeon, K M; Yoo, S J; Seo, J K; Choi, J H

    2000-05-01

    Congenital abnormalities of the portal venous system are rare. There are few radiological descriptions of intrahepatic portosystemic venous shunt detected in the perinatal period. We report a congenital portosystemic shunt that was detected by US and treated with coil embolisation in the neonatal period.

  14. Development of Monitoring and Diagnostic Methods for Robots Used In Remediation of Waste Sites - Final Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Martin, M.

    2000-04-01

    This project is the first evaluation of model-based diagnostics to hydraulic robot systems. A greater understanding of fault detection for hydraulic robots has been gained, and a new theoretical fault detection model developed and evaluated.

  15. Evaluation of selective control information detection scheme in orthogonal frequency division multiplexing-based radio-over-fiber and visible light communication links

    NASA Astrophysics Data System (ADS)

    Dalarmelina, Carlos A.; Adegbite, Saheed A.; Pereira, Esequiel da V.; Nunes, Reginaldo B.; Rocha, Helder R. O.; Segatto, Marcelo E. V.; Silva, Jair A. L.

    2017-05-01

    Block-level detection is required to decode what may be classified as selective control information (SCI) such as control format indicator in 4G-long-term evolution systems. Using optical orthogonal frequency division multiplexing over radio-over-fiber (RoF) links, we report the experimental evaluation of an SCI detection scheme based on a time-domain correlation (TDC) technique in comparison with the conventional maximum likelihood (ML) approach. When compared with the ML method, it is shown that the TDC method improves detection performance over both 20 and 40 km of standard single mode fiber (SSMF) links. We also report a performance analysis of the TDC scheme in noisy visible light communication channel models after propagation through 40 km of SSMF. Experimental and simulation results confirm that the TDC method is attractive for practical orthogonal frequency division multiplexing-based RoF and fiber-wireless systems. Unlike the ML method, another key benefit of the TDC is that it requires no channel estimation.

  16. Label-free detection of real-time DNA amplification using a nanofluidic diffraction grating

    NASA Astrophysics Data System (ADS)

    Yasui, Takao; Ogawa, Kensuke; Kaji, Noritada; Nilsson, Mats; Ajiri, Taiga; Tokeshi, Manabu; Horiike, Yasuhiro; Baba, Yoshinobu

    2016-08-01

    Quantitative DNA amplification using fluorescence labeling has played an important role in the recent, rapid progress of basic medical and molecular biological research. Here we report a label-free detection of real-time DNA amplification using a nanofluidic diffraction grating. Our detection system observed intensity changes during DNA amplification of diffracted light derived from the passage of a laser beam through nanochannels embedded in a microchannel. Numerical simulations revealed that the diffracted light intensity change in the nanofluidic diffraction grating was attributed to the change of refractive index. We showed the first case reported to date for label-free detection of real-time DNA amplification, such as specific DNA sequences from tubercle bacilli (TB) and human papillomavirus (HPV). Since our developed system allows quantification of the initial concentration of amplified DNA molecules ranging from 1 fM to 1 pM, we expect that it will offer a new strategy for developing fundamental techniques of medical applications.

  17. Design and characterization of the Large-aperture Experiment to Detect the Dark Age (LEDA) radiometer systems

    NASA Astrophysics Data System (ADS)

    Price, D. C.; Greenhill, L. J.; Fialkov, A.; Bernardi, G.; Garsden, H.; Barsdell, B. R.; Kocz, J.; Anderson, M. M.; Bourke, S. A.; Craig, J.; Dexter, M. R.; Dowell, J.; Eastwood, M. W.; Eftekhari, T.; Ellingson, S. W.; Hallinan, G.; Hartman, J. M.; Kimberk, R.; Lazio, T. Joseph W.; Leiker, S.; MacMahon, D.; Monroe, R.; Schinzel, F.; Taylor, G. B.; Tong, E.; Werthimer, D.; Woody, D. P.

    2018-05-01

    The Large-Aperture Experiment to Detect the Dark Age (LEDA) was designed to detect the predicted O(100) mK sky-averaged absorption of the Cosmic Microwave Background by Hydrogen in the neutral pre- and intergalactic medium just after the cosmological Dark Age. The spectral signature would be associated with emergence of a diffuse Lyα background from starlight during `Cosmic Dawn'. Recently, Bowman et al. (2018) have reported detection of this predicted absorption feature, with an unexpectedly large amplitude of 530 mK, centered at 78 MHz. Verification of this result by an independent experiment, such as LEDA, is pressing. In this paper, we detail design and characterization of the LEDA radiometer systems, and a first-generation pipeline that instantiates a signal path model. Sited at the Owens Valley Radio Observatory Long Wavelength Array, LEDA systems include the station correlator, five well-separated redundant dual polarization radiometers and backend electronics. The radiometers deliver a 30-85 MHz band (16 < z < 34) and operate as part of the larger interferometric array, for purposes ultimately of in situ calibration. Here, we report on the LEDA system design, calibration approach, and progress in characterization as of January 2016. The LEDA systems are currently being modified to improve performance near 78 MHz in order to verify the purported absorption feature.

  18. Detection of small molecules with a flow immunosensor

    NASA Technical Reports Server (NTRS)

    Kusterbeck, Anne W.; Ligler, Frances S.

    1991-01-01

    We describe the development of an easy-to-use sensor with widespread applications for detecting small molecules. The flow immunosensor can analyze discrete samples in under one minute or continuously monitor a flowing stream for the presence of specific analytes. This detection system is extremely specific, and achieves a level of sensitivity which meets or exceeds the detection limits reported for rival assays. Because the system is also compact, transportable, and automated, it has the potential to impact diverse areas. For example, the flow immunosensor has successfully detected drugs of abuse and explosives, and may well address many of the needs of the environmental community with respect to continuous monitoring for pollutants. Efforts are underway to engineer a portable device in the field.

  19. Integration of a Self-Coherence Algorithm into DISAT for Forced Oscillation Detection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Follum, James D.; Tuffner, Francis K.; Amidan, Brett G.

    2015-03-03

    With the increasing number of phasor measurement units on the power system, behaviors typically not observable on the power system are becoming more apparent. Oscillatory behavior on the power system, notably forced oscillations, are one such behavior. However, the large amounts of data coming from the PMUs makes manually detecting and locating these oscillations difficult. To automate portions of the process, an oscillation detection routine was coded into the Data Integrity and Situational Awareness Tool (DISAT) framework. Integration into the DISAT framework allows forced oscillations to be detected and information about the event provided to operational engineers. The oscillation detectionmore » algorithm integrates with the data handling and atypical data detecting capabilities of DISAT, building off of a standard library of functions. This report details that integration with information on the algorithm, some implementation issues, and some sample results from the western United States’ power grid.« less

  20. Automated biosurveillance data from England and Wales, 1991-2011.

    PubMed

    Enki, Doyo G; Noufaily, Angela; Garthwaite, Paul H; Andrews, Nick J; Charlett, André; Lane, Chris; Farrington, C Paddy

    2013-01-01

    Outbreak detection systems for use with very large multiple surveillance databases must be suited both to the data available and to the requirements of full automation. To inform the development of more effective outbreak detection algorithms, we analyzed 20 years of data (1991-2011) from a large laboratory surveillance database used for outbreak detection in England and Wales. The data relate to 3,303 distinct types of infectious pathogens, with a frequency range spanning 6 orders of magnitude. Several hundred organism types were reported each week. We describe the diversity of seasonal patterns, trends, artifacts, and extra-Poisson variability to which an effective multiple laboratory-based outbreak detection system must adjust. We provide empirical information to guide the selection of simple statistical models for automated surveillance of multiple organisms, in the light of the key requirements of such outbreak detection systems, namely, robustness, flexibility, and sensitivity.

  1. Automated Biosurveillance Data from England and Wales, 1991–2011

    PubMed Central

    Enki, Doyo G.; Noufaily, Angela; Garthwaite, Paul H.; Andrews, Nick J.; Charlett, André; Lane, Chris

    2013-01-01

    Outbreak detection systems for use with very large multiple surveillance databases must be suited both to the data available and to the requirements of full automation. To inform the development of more effective outbreak detection algorithms, we analyzed 20 years of data (1991–2011) from a large laboratory surveillance database used for outbreak detection in England and Wales. The data relate to 3,303 distinct types of infectious pathogens, with a frequency range spanning 6 orders of magnitude. Several hundred organism types were reported each week. We describe the diversity of seasonal patterns, trends, artifacts, and extra-Poisson variability to which an effective multiple laboratory-based outbreak detection system must adjust. We provide empirical information to guide the selection of simple statistical models for automated surveillance of multiple organisms, in the light of the key requirements of such outbreak detection systems, namely, robustness, flexibility, and sensitivity. PMID:23260848

  2. Evaluation of a Broad-Spectrum Partially Automated Adverse Event Surveillance System: A Potential Tool for Patient Safety Improvement in Hospitals With Limited Resources.

    PubMed

    Saikali, Melody; Tanios, Alain; Saab, Antoine

    2017-11-21

    The aim of the study was to evaluate the sensitivity and resource efficiency of a partially automated adverse event (AE) surveillance system for routine patient safety efforts in hospitals with limited resources. Twenty-eight automated triggers from the hospital information system's clinical and administrative databases identified cases that were then filtered by exclusion criteria per trigger and then reviewed by an interdisciplinary team. The system, developed and implemented using in-house resources, was applied for 45 days of surveillance, for all hospital inpatient admissions (N = 1107). Each trigger was evaluated for its positive predictive value (PPV). Furthermore, the sensitivity of the surveillance system (overall and by AE category) was estimated relative to incidence ranges in the literature. The surveillance system identified a total of 123 AEs among 283 reviewed medical records, yielding an overall PPV of 52%. The tool showed variable levels of sensitivity across and within AE categories when compared with the literature, with a relatively low overall sensitivity estimated between 21% and 44%. Adverse events were detected in 23 of the 36 AE categories defined by an established harm classification system. Furthermore, none of the detected AEs were voluntarily reported. The surveillance system showed variable sensitivity levels across a broad range of AE categories with an acceptable PPV, overcoming certain limitations associated with other harm detection methods. The number of cases captured was substantial, and none had been previously detected or voluntarily reported. For hospitals with limited resources, this methodology provides valuable safety information from which interventions for quality improvement can be formulated.

  3. A progress report on UNICOS misuse detection at Los Alamos

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thompson, J.L.; Jackson, K.A.; Stallings, C.A.

    An effective method for detecting computer misuse is the automatic monitoring and analysis of on-line user activity. During the past year, Los Alamos enhanced its Network Anomaly Detection and Intrusion Reporter (NADIR) to include analysis of user activity on Los Alamos` UNICOS Crays. In near real-time, NADIR compares user activity to historical profiles and tests activity against expert rules. The expert rules express Los Alamos` security policy and define improper or suspicious behavior. NADIR reports suspicious behavior to security auditors and provides tools to aid in follow-up investigations. This paper describes the implementation to date of the UNICOS component ofmore » NADIR, along with the operational experiences and future plans for the system.« less

  4. Integrated explosive preconcentrator and electrochemical detection system for 2,4,6-trinitrotoluene (TNT) vapor.

    PubMed

    Cizek, Karel; Prior, Chad; Thammakhet, Chongdee; Galik, Michal; Linker, Kevin; Tsui, Ray; Cagan, Avi; Wake, John; La Belle, Jeff; Wang, Joseph

    2010-02-19

    This article reports on an integrated explosive-preconcentration/electrochemical detection system for 2,4,6-trinitrotoluene (TNT) vapor. The challenges involved in such system integration are discussed. A hydrogel-coated screen-printed electrode is used for the detection of the thermally desorbed TNT from a preconcentration device using rapid square wave voltammetry. Optimization of the preconcentration system for desorption of TNT and subsequent electrochemical detection was conducted yielding a desorption temperature of 120 degrees C under a flow rate of 500 mL min(-1). Such conditions resulted in a characteristic electrochemical signal for TNT representing the multi-step reduction process. Quantitative measurements produced a linear signal dependence on TNT quantity exposed to the preconcentrator from 0.25 to 10 microg. Finally, the integrated device was successfully demonstrated using a sample of solid TNT located upstream of the preconcentrator. Copyright 2009 Elsevier B.V. All rights reserved.

  5. DNA detection and single nucleotide mutation identification using SERS for molecular diagnostics and global health

    NASA Astrophysics Data System (ADS)

    Ngo, Hoan T.; Gandra, Naveen; Fales, Andrew M.; Taylor, Steve M.; Vo-Dinh, Tuan

    2017-02-01

    Nucleic acid-based molecular diagnostics at the point-of-care (POC) and in resource-limited settings is still a challenge. We present a sensitive yet simple DNA detection method with single nucleotide polymorphism (SNP) identification capability. The detection scheme involves sandwich hybridization of magnetic beads conjugated with capture probes, target sequences, and ultrabright surface-enhanced Raman Scattering (SERS) nanorattles conjugated with reporter probes. Upon hybridization, the sandwich probes are concentrated at the detection focus controlled by a magnetic system for SERS measurements. The ultrabright SERS nanorattles, consisting of a core and a shell with resonance Raman reporters loaded in the gap space between the core and the shell, serve as SERS tags for ultrasensitive signal detection. Specific DNA sequences of the malaria parasite Plasmodium falciparum and dengue virus 1 (DENV1) were used as the model marker system. Detection limit of approximately 100 attomoles was achieved. Single nucleotide polymorphism (SNP) discrimination of wild type malaria DNA and mutant malaria DNA, which confers resistance to artemisinin drugs, was also demonstrated. The results demonstrate the molecular diagnostic potential of the nanorattle-based method to both detect and genotype infectious pathogens. The method's simplicity makes it a suitable candidate for molecular diagnosis at the POC and in resource-limited settings.

  6. Architectural Analysis of a LLNL LWIR Sensor System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bond, Essex J.; Curry, Jim R.; LaFortune, Kai N.

    The architecture of an LLNL airborne imaging and detection system is considered in this report. The purpose of the system is to find the location of substances of interest by detecting their chemical signatures using a long-wave infrared (LWIR) imager with geo-registration capability. The detection system consists of an LWIR imaging spectrometer as well as a network of computer hardware and analysis software for analyzing the images for the features of interest. The system has been in the operations phase now for well over a year, and as such, there is enough use data and feedback from the primary beneficiarymore » to assess the current successes and shortcomings of the LWIR system architecture. LWIR system has been successful in providing reliable data collection and the delivery of a report with results. The weakness of the architecture has been identified in two areas: with the network of computer hardware and software and with the feedback of the state of the system health. Regarding the former, the system computers and software that carry out the data acquisition are too complicated for routine operations and maintenance. With respect to the latter, the primary beneficiary of the instrument’s data does not have enough metrics to use to filter the large quantity of data to determine its utility. In addition to the needs in these two areas, a latent need of one of the stakeholders is identified. This report documents the strengths and weaknesses, as well as proposes a solution for enhancing the architecture that simultaneously addresses the two areas of weakness and leverages them to meet the newly identified latent need.« less

  7. Combing signals from spontaneous reports and electronic health records for detection of adverse drug reactions

    PubMed Central

    Harpaz, Rave; Vilar, Santiago; DuMouchel, William; Salmasian, Hojjat; Haerian, Krystl; Shah, Nigam H; Chase, Herbert S; Friedman, Carol

    2013-01-01

    Objective Data-mining algorithms that can produce accurate signals of potentially novel adverse drug reactions (ADRs) are a central component of pharmacovigilance. We propose a signal-detection strategy that combines the adverse event reporting system (AERS) of the Food and Drug Administration and electronic health records (EHRs) by requiring signaling in both sources. We claim that this approach leads to improved accuracy of signal detection when the goal is to produce a highly selective ranked set of candidate ADRs. Materials and methods Our investigation was based on over 4 million AERS reports and information extracted from 1.2 million EHR narratives. Well-established methodologies were used to generate signals from each source. The study focused on ADRs related to three high-profile serious adverse reactions. A reference standard of over 600 established and plausible ADRs was created and used to evaluate the proposed approach against a comparator. Results The combined signaling system achieved a statistically significant large improvement over AERS (baseline) in the precision of top ranked signals. The average improvement ranged from 31% to almost threefold for different evaluation categories. Using this system, we identified a new association between the agent, rasburicase, and the adverse event, acute pancreatitis, which was supported by clinical review. Conclusions The results provide promising initial evidence that combining AERS with EHRs via the framework of replicated signaling can improve the accuracy of signal detection for certain operating scenarios. The use of additional EHR data is required to further evaluate the capacity and limits of this system and to extend the generalizability of these results. PMID:23118093

  8. Simultaneous determination of low-molecular-weight organic acids and chlorinated acid herbicides in environmental water by a portable CE system with contactless conductivity detection.

    PubMed

    Xu, Yan; Wang, Weilong; Li, Sam Fong Yau

    2007-05-01

    This report describes a method to simultaneously determine 11 low-molecular-weight (LMW) organic acids and 16 chlorinated acid herbicides within a single run by a portable CE system with contactless conductivity detection (CCD) in a poly(vinyl alcohol) (PVA)-coated capillary. Under the optimized condition, the LODs of CE-CCD ranged from 0.056 to 0.270 ppm, which were better than for indirect UV (IUV) detection of the 11 LMW organic acids or UV detection of the 16 chlorinated acid herbicides. Combined with an on-line field-amplified sample stacking (FASS) procedure, sensitivity enhancement of 632- to 1078-fold was achieved, with satisfactory reproducibility (RSDs of migration times less than 2.2%, and RSDs of peak areas less than 5.1%). The FASS-CE-CCD method was successfully applied to determine the two groups of acidic pollutants in two kinds of environmental water samples. The portable CE-CCD system shows advantages such as simplicity, cost effectiveness, and miniaturization. Therefore, the method presented in this report has great potential for onsite analysis of various pollutants at the trace level.

  9. Immunity-Based Aircraft Fault Detection System

    NASA Technical Reports Server (NTRS)

    Dasgupta, D.; KrishnaKumar, K.; Wong, D.; Berry, M.

    2004-01-01

    In the study reported in this paper, we have developed and applied an Artificial Immune System (AIS) algorithm for aircraft fault detection, as an extension to a previous work on intelligent flight control (IFC). Though the prior studies had established the benefits of IFC, one area of weakness that needed to be strengthened was the control dead band induced by commanding a failed surface. Since the IFC approach uses fault accommodation with no detection, the dead band, although it reduces over time due to learning, is present and causes degradation in handling qualities. If the failure can be identified, this dead band can be further A ed to ensure rapid fault accommodation and better handling qualities. The paper describes the application of an immunity-based approach that can detect a broad spectrum of known and unforeseen failures. The approach incorporates the knowledge of the normal operational behavior of the aircraft from sensory data, and probabilistically generates a set of pattern detectors that can detect any abnormalities (including faults) in the behavior pattern indicating unsafe in-flight operation. We developed a tool called MILD (Multi-level Immune Learning Detection) based on a real-valued negative selection algorithm that can generate a small number of specialized detectors (as signatures of known failure conditions) and a larger set of generalized detectors for unknown (or possible) fault conditions. Once the fault is detected and identified, an adaptive control system would use this detection information to stabilize the aircraft by utilizing available resources (control surfaces). We experimented with data sets collected under normal and various simulated failure conditions using a piloted motion-base simulation facility. The reported results are from a collection of test cases that reflect the performance of the proposed immunity-based fault detection algorithm.

  10. Dual fluorescence/contactless conductivity detection for microfluidic chip.

    PubMed

    Liu, Cui; Mo, Yun-yan; Chen, Zuan-guang; Li, Xiang; Li, Ou-lian; Zhou, Xie

    2008-07-28

    A new dual detection system for microchip is reported. Both fluorescence detector (FD) and contactless conductivity detector (CCD) were combined together and integrated on a microfluidic chip. They shared a common detection position and responded simultaneously. A blue light-emitting diode was used as excitation source and a small planar photodiode was used to collect the emitted fluorescence in fluorescence detection, which made the device more compact and portable. The coupling of the fluorescence and contactless conductivity modes at the same position of a single separation channel enhanced the detection characterization of sample and offered simultaneous detection information of both fluorescent and charged specimen. The detection conditions of the system were optimized. K(+), Na(+), fluorescein sodium, fluorescein isothiocyanate (FITC) and FITC-labeled amino acids were used to evaluate the performance of the dual detection system. The limits of detection (LOD) of FD for fluorescein Na(+), FITC, FITC-labeled arginine (Arg), glycine (Gly) and phenylalanine (Phe) were 0.02micromolL(-1), 0.05micromolL(-1), 0.16micromolL(-1), 0.15micromolL(-1), 0.12micromolL(-1) respectively, and the limits of detection (LOD) of CCD achieved 0.58micromolL(-1) and 0.39micromolL(-1) for K(+) and Na(+) respectively.

  11. A Survey of Security Tools for the Industrial Control System Environment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hurd, Carl M.; McCarty, Michael V.

    This report details the results of a survey conducted by Idaho National Laboratory (INL) to identify existing tools which could be used to prevent, detect, mitigate, or investigate a cyber-attack in an industrial control system (ICS) environment. This report compiles a list of potentially applicable tools and shows the coverage of the tools in an ICS architecture.

  12. The Error Prone Model and the Basic Grants Validation Selection System. Draft Final Report.

    ERIC Educational Resources Information Center

    System Development Corp., Falls Church, VA.

    An evaluation of existing and proposed mechanisms to ensure data accuracy for the Pell Grant program is reported, and recommendations for efficient detection of fraud and error in the program are offered. One study objective was to examine the existing system of pre-established criteria (PEC), which are validation criteria that select students on…

  13. Air Data Report Improves Flight Safety

    NASA Technical Reports Server (NTRS)

    2007-01-01

    NASA's Aviation Safety Program in the NASA Aeronautics Research Mission Directorate, which seeks to make aviation safer by developing tools for flight data analysis and interpretation and then by transferring these tools to the aviation industry, sponsored the development of Morning Report software. The software, created at Ames Research Center with the assistance of the Pacific Northwest National Laboratory, seeks to detect atypicalities without any predefined parameters-it spots deviations and highlights them. In 2004, Sagem Avionics Inc. entered a licensing agreement with NASA for the commercialization of the Morning Report software, and also licensed the NASA Aviation Data Integration System (ADIS) tool, which allows for the integration of data from disparate sources into the flight data analysis process. Sagem Avionics incorporated the Morning Report tool into its AGS product, a comprehensive flight operations monitoring system that helps users detect irregular or divergent practices, technical flaws, and problems that might develop when aircraft operate outside of normal procedures. Sagem developed AGS in collaboration with airlines, so that the system takes into account their technical evolutions and needs, and each airline is able to easily perform specific treatments and to build its own flight data analysis system. Further, the AGS is designed to support any aircraft and flight data recorders.

  14. CAPILLARY GAS CHROMATOGRAPHY-ATOMIC EMISSION DETECTION METHOD FOR THE DETERMINATION OF PENTYLATED ORGANOTIN COMPOUNDS: INTERLABORATORY STUDY

    EPA Science Inventory

    A capillary gas chromatography-atomic emission detection (GC-AED) method was developed for the U. S. Environmental Protection Agency's Environmental Monitoring Systems Laboratory in Las Vegas, NV, for determination of selected organotin compounds. Here we report on an interlabora...

  15. New Southern Cataclysmic Variables: Discoveries from MASTER-SAAO

    NASA Astrophysics Data System (ADS)

    Buckley, D. A. H.; Potter, S. B.; Kniazev, A.; Lipunov, V.; Gorbovskoy, E.; Tiurina, N.

    2017-03-01

    In this paper we report on new cataclysmic variables (CVs) discovered by the first local optical transient detection system established at the SAAO Sutherland station, namely MASTER-SAAO. The characteristics of the MASTER-SAAO system are described and the parameters of the survey compared to the Catalina Real Time Survey (CRTS). To date MASTER-SAAO has discovered over 200 (non-Solar System) optical transients with about 75% of these being likely new CVs, most being dwarf novae (DNe). Approximately 50% of the DNe have outburst amplitudes in excess of 4 magnitudes, with some extreme amplitude (> 7 mag), probable WZ Sge systems. The MASTER-SAAO detection limit of B = 19-20 is comparable to the ˜20 magnitude limit of the CRTS (depending on CV colour). Based on the CV detection statistics of CRTS, we believe that MASTER-SAAO is detecting essentially the same CV population as CRTS, for a detection outburst amplitude threshold >2.2 magnitudes. We also present results of the initial follow-up program on CVs discovered by MASTER, including dwarf novae, a bright new VY Scl system and a new eclipsing polar.

  16. Factors influencing performance of internet-based biosurveillance systems used in epidemic intelligence for early detection of infectious diseases outbreaks.

    PubMed

    Barboza, Philippe; Vaillant, Laetitia; Le Strat, Yann; Hartley, David M; Nelson, Noele P; Mawudeku, Abla; Madoff, Lawrence C; Linge, Jens P; Collier, Nigel; Brownstein, John S; Astagneau, Pascal

    2014-01-01

    Internet-based biosurveillance systems have been developed to detect health threats using information available on the Internet, but system performance has not been assessed relative to end-user needs and perspectives. Infectious disease events from the French Institute for Public Health Surveillance (InVS) weekly international epidemiological bulletin published in 2010 were used to construct the gold-standard official dataset. Data from six biosurveillance systems were used to detect raw signals (infectious disease events from informal Internet sources): Argus, BioCaster, GPHIN, HealthMap, MedISys and ProMED-mail. Crude detection rates (C-DR), crude sensitivity rates (C-Se) and intrinsic sensitivity rates (I-Se) were calculated from multivariable regressions to evaluate the systems' performance (events detected compared to the gold-standard) 472 raw signals (Internet disease reports) related to the 86 events included in the gold-standard data set were retrieved from the six systems. 84 events were detected before their publication in the gold-standard. The type of sources utilised by the systems varied significantly (p<0001). I-Se varied significantly from 43% to 71% (p=0001) whereas other indicators were similar (C-DR: p=020; C-Se, p=013). I-Se was significantly associated with individual systems, types of system, languages, regions of occurrence, and types of infectious disease. Conversely, no statistical difference of C-DR was observed after adjustment for other variables. Although differences could result from a biosurveillance system's conceptual design, findings suggest that the combined expertise amongst systems enhances early detection performance for detection of infectious diseases. While all systems showed similar early detection performance, systems including human moderation were found to have a 53% higher I-Se (p=00001) after adjustment for other variables. Overall, the use of moderation, sources, languages, regions of occurrence, and types of cases were found to influence system performance.

  17. Evaluation of a fault tolerant system for an integrated avionics sensor configuration with TSRV flight data

    NASA Technical Reports Server (NTRS)

    Caglayan, A. K.; Godiwala, P. M.

    1985-01-01

    The performance analysis results of a fault inferring nonlinear detection system (FINDS) using sensor flight data for the NASA ATOPS B-737 aircraft in a Microwave Landing System (MLS) environment is presented. First, a statistical analysis of the flight recorded sensor data was made in order to determine the characteristics of sensor inaccuracies. Next, modifications were made to the detection and decision functions in the FINDS algorithm in order to improve false alarm and failure detection performance under real modelling errors present in the flight data. Finally, the failure detection and false alarm performance of the FINDS algorithm were analyzed by injecting bias failures into fourteen sensor outputs over six repetitive runs of the five minute flight data. In general, the detection speed, failure level estimation, and false alarm performance showed a marked improvement over the previously reported simulation runs. In agreement with earlier results, detection speed was faster for filter measurement sensors soon as MLS than for filter input sensors such as flight control accelerometers.

  18. Detection of disease outbreaks by the use of oral manifestations.

    PubMed

    Torres-Urquidy, M H; Wallstrom, G; Schleyer, T K L

    2009-01-01

    Oral manifestations of diseases caused by bioterrorist agents could be a potential data source for biosurveillance. This study had the objectives of determining the oral manifestations of diseases caused by bioterrorist agents, measuring the prevalence of these manifestations in emergency department reports, and constructing and evaluating a detection algorithm based on them. We developed a software application to detect oral manifestations in free text and identified positive reports over three years of data. The normal frequency in reports for oral manifestations related to anthrax (including buccal ulcers-sore throat) was 7.46%. The frequency for tularemia was 6.91%. For botulism and smallpox, the frequencies were 0.55% and 0.23%. We simulated outbreaks for these bioterrorism diseases and evaluated the performance of our system. The detection algorithm performed better for smallpox and botulism than for anthrax and tularemia. We found that oral manifestations can be a valuable tool for biosurveillance.

  19. Towards toxicity detection using a lab-on-chip based on the integration of MOEMS and whole-cell sensors.

    PubMed

    Elman, Noel M; Ben-Yoav, Hadar; Sternheim, Marek; Rosen, Rachel; Krylov, Slava; Shacham-Diamand, Yosi

    2008-06-15

    A lab-on-chip consisting of a unique integration of whole-cell sensors, a MOEMS (Micro-Opto-Electro-Mechanical-System) modulator, and solid-state photo-detectors was implemented for the first time. Whole-cell sensors were genetically engineered to express a bioluminescent reporter (lux) as a function of the lac promoter. The MOEMS modulator was designed to overcome the inherent low frequency noise of solid-state photo-detectors by means of a previously reported modulation technique, named IHOS (Integrated Heterodyne Optical System). The bio-reporter signals were modulated prior to photo-detection, increasing the SNR of solid-state photo-detectors at least by three orders of magnitude. Experiments were performed using isopropyl-beta-d-thiogalactopyranoside (IPTG) as a preliminary step towards testing environmental toxicity. The inducer was used to trigger the expression response of the whole-cell sensors testing the sensitivity of the lab-on-chip. Low intensity bio-reporter optical signals were measured after the whole-cell sensors were exposed to IPTG concentrations of 0.1, 0.05, and 0.02mM. The experimental results reveal the potential of this technology for future implementation as an inexpensive massive method for rapid environmental toxicity detection.

  20. Barriers in detecting elder abuse among emergency medical technicians.

    PubMed

    Reingle Gonzalez, Jennifer M; Cannell, M Brad; Jetelina, Katelyn K; Radpour, Sepeadeh

    2016-09-02

    Elder abuse and neglect are highly under-reported in the United States. This may be partially attributed to low incidence of reporting among emergency medical technicians' (EMTs), despite state-mandated reporting of suspected elder abuse. Innovative solutions are needed to address under-reporting. The objective was to describe EMTs' experience detecting and reporting elder abuse. Qualitative data were collected from 11 EMTs and 12 Adult Protective Services (APS) caseworkers that participated in one of five semi-structured focus groups. Focus group data were iteratively coded by two coders. Findings suggest a number of barriers prevent EMTs from reporting elder abuse to APS. Participants suggested that limited training on elder abuse detection or reporting has been provided to them. EMTs suggested that training, creation of an automated reporting system or brief screening tool could be used to enhance EMT's ability to detect and communicate suspected cases of elder abuse to APS. Results from the present study suggest that EMTs may be uniquely situated to serve as elder abuse and neglect surveillance personnel. EMTs are eager to work with APS to address the under-reporting of elder abuse and neglect, but training is minimal and current reporting procedures are time-prohibitive given their primary role as emergency healthcare providers. Future studies should seek to translate these findings into practice by identifying specific indicators predictive of elder abuse and neglect for inclusion on an automated reporting instrument for EMTs.

  1. Sensitivity of the Dengue Surveillance System in Brazil for Detecting Hospitalized Cases

    PubMed Central

    2016-01-01

    We evaluated the sensitivity of the dengue surveillance system in detecting hospitalized cases in ten capital cities in Brazil from 2008 to 2013 using a probabilistic record linkage of two independent information systems hospitalization (SIH-SUS) adopted as the gold standard and surveillance (SINAN). Sensitivity was defined as the proportion of cases reported to the surveillance system amid the suspected hospitalized cases registered in SIH-SUS. Of the 48,174 hospitalizations registered in SIH-SUS, 24,469 (50.7%) were reported and registered in SINAN, indicating an overall sensitivity of 50.8% (95%CI 50.3–51.2). The observed sensitivity for each of the municipalities included in the study ranged from 22.0% to 99.1%. The combination of the two data sources identified 71,161 hospitalizations, an increase of 97.0% over SINAN itself. Our results allowed establishing the proportion of underreported dengue hospitalizations in the public health system in Brazil, highlighting the use of probabilistic record linkage as a valuable tool for evaluating surveillance systems. PMID:27192405

  2. Distributed gas sensing with optical fibre photothermal interferometry.

    PubMed

    Lin, Yuechuan; Liu, Fei; He, Xiangge; Jin, Wei; Zhang, Min; Yang, Fan; Ho, Hoi Lut; Tan, Yanzhen; Gu, Lijuan

    2017-12-11

    We report the first distributed optical fibre trace-gas detection system based on photothermal interferometry (PTI) in a hollow-core photonic bandgap fibre (HC-PBF). Absorption of a modulated pump propagating in the gas-filled HC-PBF generates distributed phase modulation along the fibre, which is detected by a dual-pulse heterodyne phase-sensitive optical time-domain reflectometry (OTDR) system. Quasi-distributed sensing experiment with two 28-meter-long HC-PBF sensing sections connected by single-mode transmission fibres demonstrated a limit of detection (LOD) of ∼10 ppb acetylene with a pump power level of 55 mW and an effective noise bandwidth (ENBW) of 0.01 Hz, corresponding to a normalized detection limit of 5.5ppb⋅W/Hz. Distributed sensing experiment over a 200-meter-long sensing cable made of serially connected HC-PBFs demonstrated a LOD of ∼ 5 ppm with 62.5 mW peak pump power and 11.8 Hz ENBW, or a normalized detection limit of 312ppb⋅W/Hz. The spatial resolution of the current distributed detection system is limited to ∼ 30 m, but it is possible to reduce down to 1 meter or smaller by optimizing the phase detection system.

  3. Developing a Digital Medicine System in Psychiatry: Ingestion Detection Rate and Latency Period.

    PubMed

    Profit, Deborah; Rohatagi, Shashank; Zhao, Cathy; Hatch, Ainslie; Docherty, John P; Peters-Strickland, Timothy S

    2016-09-01

    A digital medicine system (DMS) has been developed to measure and report adherence to an atypical antipsychotic, aripiprazole, in psychiatric patients. The DMS consists of 3 components: ingestible sensor embedded in a medication tablet, wearable sensor, and secure mobile and cloud-based applications. An umbrella study protocol was designed to rapidly assess the technical performance and safety of the DMS in multiple substudies to guide the technology development. Two sequential substudies enrolled 30 and 29 healthy volunteers between March-April 2014 and February-March 2015, respectively, to assess detection accuracy of the ingestible sensor by the DMS and the latency period between ingestion and detection of the ingestion by the wearable sensor or the cloud-based server. The first substudy identified areas for improvement using early versions of the wearable sensor and the mobile application. The second substudy tested updated versions of the components and showed an overall ingestion detection rate of 96.6%. Mean latency times for the signal transmission were 1.1-1.3 minutes (from ingestion to the wearable sensor detection) and 6.2-10.3 minutes (from the wearable sensor detection to the server detection). Half of transmissions were completed in < 2 minutes, and ~90% of ingestions were registered by the smartphone within 30 minutes of ingestion. No serious adverse events, discontinuations, or clinically significant laboratory/vital signs findings were reported. The DMS implementing modified versions of the smartphone application and the wearable sensor has the technical capability to detect and report tablet ingestion with high accuracy and acceptable latency time. ClinicalTrials.gov identifier: NCT02091882. © Copyright 2016 Physicians Postgraduate Press, Inc.

  4. LacI(Ts)-Regulated Expression as an In Situ Intracellular Biomolecular Thermometer▿

    PubMed Central

    McCabe, K. M.; Lacherndo, E. J.; Albino-Flores, I.; Sheehan, E.; Hernandez, M.

    2011-01-01

    In response to needs for in situ thermometry, a temperature-sensitive vector was adapted to report changes in the intracellular heat content of Escherichia coli in near-real time. This model system utilized vectors expressing increasing quantities of β-galactosidase in response to stepwise temperature increases through a biologically relevant range (22 to 45°C). As judged by calibrated fluorometric and colorimetric reporters, both whole E. coli cells and lysates expressed significant repeatable changes in β-galactosidase activity that were sensitive to temperature changes of less than 1°C (35 to 45°C). This model system suggests that changes in cellular heat content can be detected independently of the medium in which cells are maintained, a feature of particular importance where the medium is heterogeneous or nonaqueous, or otherwise has a low heat transfer capacity. We report here that the intracellular temperature can be reliably obtained in near-real time using reliable fluorescent reporting systems from cellular scales, with a 20°C range of detection and at least 0.7°C sensitivity between 35 and 45°C. PMID:21378059

  5. Investigation of Coherent and Incoherent Change Detection Algorithms

    DTIC Science & Technology

    2017-12-01

    Office of Management and Budget, Paperwork Reduction Project (0704-0188) Washington DC 20503. 1. AGENCY USE ONLY (Leave blank) 2. REPORT DATE December...Data Management System (SDMS) in order to compare the various change detection techniques. These change detection methods include the following: a...SAR) is presented in this thesis. This investigation utilizes data gathered from the Air Force Research Laboratory (AFRL) Sensor Data Management

  6. A rapid field detection system for citrus huanglongbing associated ‘Candidatus Liberibacter asiaticus’ from the psyllid vector, diaphorina citri kuwayama and its implications in disease management

    USDA-ARS?s Scientific Manuscript database

    We report the development of an affordable detection kit for the detection of ‘Candidatus Liberibacter asiaticus’ (Las) from the psyllid vector, Diaphorina citri, which can provide real time test results in the field or field laboratory within 30-40 minutes without the need for expensive laboratory ...

  7. Factors Influencing Performance of Internet-Based Biosurveillance Systems Used in Epidemic Intelligence for Early Detection of Infectious Diseases Outbreaks

    PubMed Central

    Barboza, Philippe; Vaillant, Laetitia; Le Strat, Yann; Hartley, David M.; Nelson, Noele P.; Mawudeku, Abla; Madoff, Lawrence C.; Linge, Jens P.; Collier, Nigel; Brownstein, John S.; Astagneau, Pascal

    2014-01-01

    Background Internet-based biosurveillance systems have been developed to detect health threats using information available on the Internet, but system performance has not been assessed relative to end-user needs and perspectives. Method and Findings Infectious disease events from the French Institute for Public Health Surveillance (InVS) weekly international epidemiological bulletin published in 2010 were used to construct the gold-standard official dataset. Data from six biosurveillance systems were used to detect raw signals (infectious disease events from informal Internet sources): Argus, BioCaster, GPHIN, HealthMap, MedISys and ProMED-mail. Crude detection rates (C-DR), crude sensitivity rates (C-Se) and intrinsic sensitivity rates (I-Se) were calculated from multivariable regressions to evaluate the systems’ performance (events detected compared to the gold-standard) 472 raw signals (Internet disease reports) related to the 86 events included in the gold-standard data set were retrieved from the six systems. 84 events were detected before their publication in the gold-standard. The type of sources utilised by the systems varied significantly (p<0001). I-Se varied significantly from 43% to 71% (p = 0001) whereas other indicators were similar (C-DR: p = 020; C-Se, p = 013). I-Se was significantly associated with individual systems, types of system, languages, regions of occurrence, and types of infectious disease. Conversely, no statistical difference of C-DR was observed after adjustment for other variables. Conclusion Although differences could result from a biosurveillance system's conceptual design, findings suggest that the combined expertise amongst systems enhances early detection performance for detection of infectious diseases. While all systems showed similar early detection performance, systems including human moderation were found to have a 53% higher I-Se (p = 00001) after adjustment for other variables. Overall, the use of moderation, sources, languages, regions of occurrence, and types of cases were found to influence system performance. PMID:24599062

  8. Proceedings of the 9th Annual Conference on Manual Control

    NASA Technical Reports Server (NTRS)

    1973-01-01

    Papers are reported which were presented at the conference in the areas of displays, ride qualities and handling, driving and psychomotor skills, control, system identification and signal detection, electrophysiological and systems analysis, and modelling.

  9. The Telecommunications and Data Acquisition Report

    NASA Technical Reports Server (NTRS)

    Posner, E. C. (Editor)

    1988-01-01

    The Office of Space Operation (OSO) tasks addressed include: Deep Space Network (DSN) advanced systems and systems implementation. The Office of Space Science and Applications (OSSA) tasks discussed include SETI data controllers and simulated performance for narrowband signal detection.

  10. PACS-Based Computer-Aided Detection and Diagnosis

    NASA Astrophysics Data System (ADS)

    Huang, H. K. (Bernie); Liu, Brent J.; Le, Anh HongTu; Documet, Jorge

    The ultimate goal of Picture Archiving and Communication System (PACS)-based Computer-Aided Detection and Diagnosis (CAD) is to integrate CAD results into daily clinical practice so that it becomes a second reader to aid the radiologist's diagnosis. Integration of CAD and Hospital Information System (HIS), Radiology Information System (RIS) or PACS requires certain basic ingredients from Health Level 7 (HL7) standard for textual data, Digital Imaging and Communications in Medicine (DICOM) standard for images, and Integrating the Healthcare Enterprise (IHE) workflow profiles in order to comply with the Health Insurance Portability and Accountability Act (HIPAA) requirements to be a healthcare information system. Among the DICOM standards and IHE workflow profiles, DICOM Structured Reporting (DICOM-SR); and IHE Key Image Note (KIN), Simple Image and Numeric Report (SINR) and Post-processing Work Flow (PWF) are utilized in CAD-HIS/RIS/PACS integration. These topics with examples are presented in this chapter.

  11. Nerve cell-mimicking liposomes as biosensor for botulinum neurotoxin complete physiological activity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Weingart, Oliver G., E-mail: Oliver.Weingart@hest.

    Botulinum neurotoxins (BoNT) are the most toxic substances known, and their neurotoxic properties and paralysing effects are exploited for medical treatment of a wide spectrum of disorders. To accurately quantify the potency of a pharmaceutical BoNT preparation, its physiological key activities (binding to membrane receptor, translocation, and proteolytic degradation of SNARE proteins) need to be determined. To date, this was only possible using animal models, or, to a limited extent, cell-based assays. We here report a novel in vitro system for BoNT/B analysis, based on nerve-cell mimicking liposomes presenting motoneuronal membrane receptors required for BoNT binding. Following triggered membrane translocationmore » of the toxin's Light Chain, the endopeptidase activity can be quantitatively monitored employing a FRET-based reporter assay within the functionalized liposomes. We were able to detect BoNT/B physiological activity at picomolar concentrations in short time, opening the possibility for future replacement of animal experimentation in pharmaceutical BoNT testing. - Highlights: • A cell-free in vitro system was used to measure BoNT/B physiological function. • The system relies on nerve-cell mimicking liposomes as a novel detection system. • A FRET-based reporter assay is used as final readout of the test system. • BoNT/B physiological activity was detected at picogram quantities in short time. • The method opens the possibility to replace animal experimentation in BoNT testing.« less

  12. Assessment of a combined gas chromatography mass spectrometer sensor (GC-MSS) system for detecting biologically relevant volatile compounds (VCs).

    PubMed

    Gould, Oliver; Wieczorek, Tomas; de Lacy Costello, Ben P J; Persad, Raj; Ratcliffe, Norman

    2017-09-26

    There have been a number of studies in which metal oxide sensors (MOS) have replaced conventional analytical detectors in gas chromatography systems. However, despite the use of these instruments in a range of applications including breath research the sensor responses (i.e. resistance changes w.r.t. concentration of VCs) remain largely unreported. This paper addresses that issue by comparing the response of a metal oxide sensor directly with a mass spectrometer (MS), whereby both detectors are interfaced to the same GC column using an s-swafer. It was demonstrated that the sensitivity of an in-house fabricated ZnO/ SnO2 thick film MOS was superior to a modern MS for the detection of a wide range of volatile compounds (VCs) of different functionalities and masses. Better techniques for detection and quantification of these VCs is valuable, as many of these compounds are commonly reported throughout the scientific literature. This is also the first published report of a combined GC-MS sensor system. These 2 different detector technologies when combined, should enhance discriminatory abilities to aid disease diagnoses using volatiles from e.g. breath, and bodily fluids. 29 chemical standards have been tested using solid phase micro-extraction; 25 of these compounds are found on human breath. In all but 2 instances the sensor exhibited the same or superior limit of detection compared to the MS. 12 stool samples from healthy participants were analysed, the sensor detected, on average 1.6 peaks more per sample than the MS. Similarly analysing the headspace of E. coli broth cultures the sensor detected 6.9 more peaks per sample versus the MS. This greater sensitivity is primarily a function of the superior limits of detection of the metal oxide sensor. This shows that systems based on the combination of chromatography systems with solid state sensors shows promise for a range of applications. © 2017 IOP Publishing Ltd.

  13. Assessment of a combined gas chromatography mass spectrometer sensor system for detecting biologically relevant volatile compounds.

    PubMed

    Gould, Oliver; Wieczorek, Tom; de Lacy Costello, Ben; Persad, Raj; Ratcliffe, Norman

    2017-12-06

    There have been a number of studies in which metal oxide sensors (MOS) have replaced conventional analytical detectors in gas chromatography systems. However, despite the use of these instruments in a range of applications including breath research the sensor responses (i.e. resistance changes w.r.t. concentration of VCs) remain largely unreported. This paper addresses that issue by comparing the response of a metal oxide sensor directly with a mass spectrometer (MS), whereby both detectors are interfaced to the same GC column using an s-swafer. It was demonstrated that the sensitivity of an in-house fabricated ZnO/SnO 2 thick film MOS was superior to a modern MS for the detection of a wide range of volatile compounds (VCs) of different functionalities and masses. Better techniques for detection and quantification of these VCs is valuable, as many of these compounds are commonly reported throughout the scientific literature. This is also the first published report of a combined GC-MS sensor system. These two different detector technologies when combined, should enhance discriminatory abilities to aid disease diagnoses using volatiles from e.g. breath, and bodily fluids. Twenty-nine chemical standards have been tested using solid phase micro-extraction; 25 of these compounds are found on human breath. In all but two instances the sensor exhibited the same or superior limit of detection compared to the MS. Twelve stool samples from healthy participants were analysed; the sensor detected, on average 1.6 peaks more per sample than the MS. Similarly, analysing the headspace of E. coli broth cultures the sensor detected 6.9 more peaks per sample versus the MS. This greater sensitivity is primarily a function of the superior limits of detection of the metal oxide sensor. This shows that systems based on the combination of chromatography systems with solid state sensors shows promise for a range of applications.

  14. Quantum cascade laser-based multipass absorption system for hydrogen peroxide detection

    NASA Astrophysics Data System (ADS)

    Cao, Yingchun; Sanchez, Nancy P.; Jiang, Wenzhe; Ren, Wei; Lewicki, Rafal; Jiang, Dongfang; Griffin, Robert J.; Tittel, Frank K.

    2015-01-01

    Hydrogen peroxide (H2O2) is a relevant molecular trace gas species, that is related to the oxidative capacity of the atmosphere, the production of radical species such as OH, the generation of sulfate aerosol via oxidation of S(IV) to S(VI), and the formation of acid rain. The detection of atmospheric H2O2 involves specific challenges due to its high reactivity and low concentration (ppbv to sub-ppbv level). Traditional methods for measuring atmospheric H2O2 concentration are often based on wet-chemistry methods that require a transfer from the gas- to liquid-phase for a subsequent determination by techniques such as fluorescence spectroscopy, which can lead to problems such as sampling artifacts and interference by other atmospheric constituents. A quartz-enhanced photoacoustic spectroscopy-based system for the measurement of atmospheric H2O2 with a detection limit of 75 ppb for 1-s integration time was previously reported. In this paper, an updated H2O2 detection system based on long-optical-path-length absorption spectroscopy by using a distributed feedback quantum cascade laser (DFB-QCL) will be described. A 7.73-μm CW-DFB-QCL and a thermoelectrically cooled infrared detector, optimized for a wavelength of 8 μm, are employed for theH2O2 sensor system. A commercial astigmatic Herriott multi-pass cell with an effective optical path-length of 76 m is utilized for the reported QCL multipass absorption system. Wavelength modulation spectroscopy (WMS) with second harmonic detection is used for enhancing the signal-to-noise-ratio. A minimum detection limit of 13.4 ppb is achieved with a 2 s sampling time. Based on an Allan-Werle deviation analysis the minimum detection limit can be improved to 1.5 ppb when using an averaging time of 300 s.

  15. Conceptual design report for the project to install leak detection in FAST-FT-534/548/549

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Galloway, K.J.

    1992-07-01

    This report provides conceptual designs and design recommendations for installing secondary containment and leak detection systems for three sumps at the Fluorinel and Storage Facility (FAST), CPP-666. The FAST facility is located at the Idaho Chemical Processing Plant (ICPP) at the Idaho National Engineering Laboratory (INEL). The three sumps receive various materials from the FAST water treatment process. This project involves sump upgrades to meet appropriate environmental requirements. The steps include: providing sump modifications or designs for the installation of leak chases and/or leakage accumulation, coating the sump concrete with a chemical resistant sealant (except for sump VES-FT-534 which ismore » already lined with stainless steel) to act as secondary containment, lining the sumps with a primary containment system, and providing a means to detect and remove primary containment leakage that may occur.« less

  16. A net fishing enrichment strategy for colorimetric detection of E. coli O157:H7

    USDA-ARS?s Scientific Manuscript database

    The strict regulatory requirements for pathogen monitoring in food systems to ensure safety demands that the detection method can recognize small numbers of pathogens. Although significant efforts on the development of biosensors have been reported with marked improvement in sensitivity, appropriate...

  17. Expanding the detection efficiency of silicon drift detectors

    NASA Astrophysics Data System (ADS)

    Schlosser, D. M.; Lechner, P.; Lutz, G.; Niculae, A.; Soltau, H.; Strüder, L.; Eckhardt, R.; Hermenau, K.; Schaller, G.; Schopper, F.; Jaritschin, O.; Liebel, A.; Simsek, A.; Fiorini, C.; Longoni, A.

    2010-12-01

    To expand the detection efficiency Silicon Drift Detectors (SDDs) with various customized radiation entrance windows, optimized detector areas and geometries have been developed. Optimum values for energy resolution, peak to background ratio (P/B) and high count rate capability support the development. Detailed results on sensors optimized for light element detection down to Boron or even lower will be reported. New developments for detecting medium and high X-ray energies by increasing the effective detector thickness will be presented. Gamma-ray detectors consisting of a SDD coupled to scintillators like CsI(Tl) and LaBr 3(Ce) have been examined. Results of the energy resolution for the 137Cs 662 keV line and the light yield (LY) of such detector systems will be reported.

  18. Counter Unmanned Aerial Systems Testing: Evaluation of VIS SWIR MWIR and LWIR passive imagers.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Birch, Gabriel Carlisle; Woo, Bryana Lynn

    This report contains analysis of unmanned aerial systems as imaged by visible, short-wave infrared, mid-wave infrared, and long-wave infrared passive devices. Testing was conducted at the Nevada National Security Site (NNSS) during the week of August 15, 2016. Target images in all spectral bands are shown and contrast versus background is reported. Calculations are performed to determine estimated pixels-on-target for detection and assessment levels, and the number of pixels needed to cover a hemisphere for detection or assessment at defined distances. Background clutter challenges are qualitatively discussed for different spectral bands, and low contrast scenarios are highlighted for long-wave infraredmore » imagers.« less

  19. Cannabinoid Poisoning by Hemp Seed Oil in a Child.

    PubMed

    Chinello, Matteo; Scommegna, Salvatore; Shardlow, Alison; Mazzoli, Francesca; De Giovanni, Nadia; Fucci, Nadia; Borgiani, Paola; Ciccacci, Cinzia; Locasciulli, Anna; Calvani, Mauro

    2017-05-01

    We report a case of mild cannabinoid poisoning in a preschool child, after 3-week ingestion of hemp seed oil prescribed by his pediatrician to strengthen his immune system. The patient presented neurological symptoms that disappeared after intravenous hydration. A possible mild withdrawal syndrome was reported after discharge. The main metabolite of Δ-tetrahydrocannabinol was detected in urine, and very low concentration of Δ-tetrahydrocannabinol was detected in the ingested product. This is, as far as we know, the first report of cannabinoid poisoning after medical prescription of hemp seed oil in a preschool child.

  20. Specific NIST projects in support of the NIJ Concealed Weapon Detection and Imaging Program

    NASA Astrophysics Data System (ADS)

    Paulter, Nicholas G.

    1998-12-01

    The Electricity Division of the National Institute of Standards and Technology is developing revised performance standards for hand-held (HH) and walk-through (WT) metal weapon detectors, test procedures and systems for these detectors, and a detection/imaging system for finding concealed weapons. The revised standards will replace the existing National Institute of Justice (NIJ) standards for HH and WT devices and will include detection performance specifications as well as system specifications (environmental conditions, mechanical strength and safety, response reproducibility and repeatability, quality assurance, test reporting, etc.). These system requirements were obtained from the Law Enforcement and corrections Technology Advisory Council, an advisory council for the NIJ. Reproducible and repeatable test procedures and appropriate measurement systems will be developed for evaluating HH and WT detection performance. A guide to the technology and application of non- eddy-current-based detection/imaging methods (such as acoustic, passive millimeter-wave and microwave, active millimeter-wave and terahertz-wave, x-ray, etc.) Will be developed. The Electricity Division is also researching the development of a high- frequency/high-speed (300 GH to 1 THz) pulse-illuminated, stand- off, video-rate, concealed weapons/contraband imaging system.

  1. In-home fall risk assessment and detection sensor system.

    PubMed

    Rantz, Marilyn J; Skubic, Marjorie; Abbott, Carmen; Galambos, Colleen; Pak, Youngju; Ho, Dominic K C; Stone, Erik E; Rui, Liyang; Back, Jessica; Miller, Steven J

    2013-07-01

    Falls are a major problem in older adults. A continuous, unobtrusive, environmentally mounted (i.e., embedded into the environment and not worn by the individual), in-home monitoring system that automatically detects when falls have occurred or when the risk of falling is increasing could alert health care providers and family members to intervene to improve physical function or manage illnesses that may precipitate falls. Researchers at the University of Missouri Center for Eldercare and Rehabilitation Technology are testing such sensor systems for fall risk assessment (FRA) and detection in older adults' apartments in a senior living community. Initial results comparing ground truth (validated measures) of FRA data and GAITRite System parameters with data captured from Microsoft(®) Kinect and pulse-Doppler radar are reported. Copyright 2013, SLACK Incorporated.

  2. IDSR as a Platform for Implementing IHR in African Countries

    PubMed Central

    Kasolo, Francis; Yoti, Zabulon; Bakyaita, Nathan; Gaturuku, Peter; Katz, Rebecca; Fischer, Julie E.

    2013-01-01

    Of the 46 countries in the World Health Organization (WHO) African region (AFRO), 43 are implementing Integrated Disease Surveillance and Response (IDSR) guidelines to improve their abilities to detect, confirm, and respond to high-priority communicable and noncommunicable diseases. IDSR provides a framework for strengthening the surveillance, response, and laboratory core capacities required by the revised International Health Regulations [IHR (2005)]. In turn, IHR obligations can serve as a driving force to sustain national commitments to IDSR strategies. The ability to report potential public health events of international concern according to IHR (2005) relies on early warning systems founded in national surveillance capacities. Public health events reported through IDSR to the WHO Emergency Management System in Africa illustrate the growing capacities in African countries to detect, assess, and report infectious and noninfectious threats to public health. The IHR (2005) provide an opportunity to continue strengthening national IDSR systems so they can characterize outbreaks and respond to public health events in the region. PMID:24041192

  3. Flow injection analysis of organic peroxide explosives using acid degradation and chemiluminescent detection of released hydrogen peroxide.

    PubMed

    Mahbub, Parvez; Zakaria, Philip; Guijt, Rosanne; Macka, Mirek; Dicinoski, Greg; Breadmore, Michael; Nesterenko, Pavel N

    2015-10-01

    The applicability of acid degradation of organic peroxides into hydrogen peroxide in a pneumatically driven flow injection system with chemiluminescence reaction with luminol and Cu(2+) as a catalyst (FIA-CL) was investigated for the fast and sensitive detection of organic peroxide explosives (OPEs). The target OPEs included hexamethylene triperoxide diamine (HMTD), triacetone triperoxide (TATP) and methylethyl ketone peroxide (MEKP). Under optimised conditions maximum degradations of 70% and 54% for TATP and HMTD, respectively were achieved at 162 µL min(-1), and 9% degradation for MEKP at 180 µL min(-1). Flow rates were precisely controlled in this single source pneumatic pressure driven multi-channel FIA system by model experiments on mixing of easily detectable component solutions. The linear range for detection of TATP, HMTD and H2O2 was 1-200 µM (r(2)=0.98-0.99) at both flow rates, while that for MEKP was 20-200 µM (r(2)=0.97) at 180 µL min(-1). The detection limits (LODs) obtained were 0.5 µM for TATP, HMTD and H2O2 and 10 µM for MEKP. The detection times varied from 1.5 to 3 min in this FIA-CL system. Whilst the LOD for H2O2 was comparable with those reported by other investigators, the LODs and analysis times for TATP and HMTD were superior, and significantly, this is the first time the detection of MEKP has been reported by FIA-CL. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Performance analysis of a fault inferring nonlinear detection system algorithm with integrated avionics flight data

    NASA Technical Reports Server (NTRS)

    Caglayan, A. K.; Godiwala, P. M.; Morrell, F. R.

    1985-01-01

    This paper presents the performance analysis results of a fault inferring nonlinear detection system (FINDS) using integrated avionics sensor flight data for the NASA ATOPS B-737 aircraft in a Microwave Landing System (MLS) environment. First, an overview of the FINDS algorithm structure is given. Then, aircraft state estimate time histories and statistics for the flight data sensors are discussed. This is followed by an explanation of modifications made to the detection and decision functions in FINDS to improve false alarm and failure detection performance. Next, the failure detection and false alarm performance of the FINDS algorithm are analyzed by injecting bias failures into fourteen sensor outputs over six repetitive runs of the five minutes of flight data. Results indicate that the detection speed, failure level estimation, and false alarm performance show a marked improvement over the previously reported simulation runs. In agreement with earlier results, detection speed is faster for filter measurement sensors such as MLS than for filter input sensors such as flight control accelerometers. Finally, the progress in modifications of the FINDS algorithm design to accommodate flight computer constraints is discussed.

  5. First step toward translation of thermophotonic lock-in imaging to dentistry as an early caries detection technology

    NASA Astrophysics Data System (ADS)

    Ojaghi, Ashkan; Parkhimchyk, Artur; Tabatabaei, Nima

    2016-09-01

    Early detection of the most prevalent oral disease worldwide, i.e., dental caries, still remains as one of the major challenges in dentistry. The current dental standard of care relies on caries detection methods, such as visual inspection and x-ray radiography, which lack the sufficient specificity and sensitivity to detect caries at early stages of formation when they can be healed. We report on the feasibility of early caries detection in a clinically and commercially viable thermophotonic imaging system. The system incorporates intensity-modulated laser light along with a low-cost long-wavelength infrared (LWIR; 8 to 14 μm) camera, providing diagnostic contrast based on the enhanced light absorption of early caries. The LWIR camera is highly suitable for integration into clinical platforms because of its low weight and cost. In addition, through theoretical modeling, we show that LWIR detection enhances the diagnostic contrast due to the minimal LWIR transmittance of enamel and suppression of the masking effect of the direct thermal Planck emission. Diagnostic performance of the system and its detection threshold are experimentally evaluated by monitoring the inception and progression of artificially induced occlusal and smooth surface caries. The results are suggestive of the suitability of the developed LWIR system for detecting early dental caries.

  6. Development and Measurements of a Mid-Infrared Multi-Gas Sensor System for CO, CO₂ and CH₄ Detection.

    PubMed

    Dong, Ming; Zheng, Chuantao; Miao, Shuzhuo; Zhang, Yu; Du, Qiaoling; Wang, Yiding; Tittel, Frank K

    2017-09-27

    A multi-gas sensor system was developed that uses a single broadband light source and multiple carbon monoxide (CO), carbon dioxide (CO₂) and methane (CH₄) pyroelectric detectors by use of the time division multiplexing (TDM) technique. A stepper motor-based rotating system and a single-reflection spherical optical mirror were designed and adopted to realize and enhance multi-gas detection. Detailed measurements under static detection mode (without rotation) and dynamic mode (with rotation) were performed to study the performance of the sensor system for the three gas species. Effects of the motor rotating period on sensor performances were also investigated and a rotation speed of 0.4π rad/s was required to obtain a stable sensing performance, corresponding to a detection period of ~10 s to realize one round of detection. Based on an Allan deviation analysis, the 1 σ detection limits under static operation are 2.96, 4.54 and 2.84 parts per million in volume (ppmv) for CO, CO₂ and CH₄, respectively and the 1 σ detection limits under dynamic operations are 8.83, 8.69 and 10.29 ppmv for the three gas species, respectively. The reported sensor has potential applications in various fields requiring CO, CO₂ and CH₄ detection such as in coal mines.

  7. Development of a Fish Cell Biosensor System for Genotoxicity Detection Based on DNA Damage-Induced Trans-Activation of p21 Gene Expression

    PubMed Central

    Geng, Deyu; Zhang, Zhixia; Guo, Huarong

    2012-01-01

    p21CIP1/WAF1 is a p53-target gene in response to cellular DNA damage. Here we report the development of a fish cell biosensor system for high throughput genotoxicity detection of new drugs, by stably integrating two reporter plasmids of pGL3-p21-luc (human p21 promoter linked to firefly luciferase) and pRL-CMV-luc (CMV promoter linked to Renilla luciferase) into marine flatfish flounder gill (FG) cells, referred to as p21FGLuc. Initial validation of this genotoxicity biosensor system showed that p21FGLuc cells had a wild-type p53 signaling pathway and responded positively to the challenge of both directly acting genotoxic agents (bleomycin and mitomycin C) and indirectly acting genotoxic agents (cyclophosphamide with metabolic activation), but negatively to cyclophosphamide without metabolic activation and the non-genotoxic agents ethanol and D-mannitol, thus confirming a high specificity and sensitivity, fast and stable response to genotoxic agents for this easily maintained fish cell biosensor system. This system was especially useful in the genotoxicity detection of Di(2-ethylhexyl) phthalate (DEHP), a rodent carcinogen, but negatively reported in most non-mammalian in vitro mutation assays, by providing a strong indication of genotoxicity for DEHP. A limitation for this biosensor system was that it might give false positive results in response to sodium butyrate and any other agents, which can trans-activate the p21 gene in a p53-independent manner. PMID:25585933

  8. SIRU development. Volume 1: System development

    NASA Technical Reports Server (NTRS)

    Gilmore, J. P.; Cooper, R. J.

    1973-01-01

    A complete description of the development and initial evaluation of the Strapdown Inertial Reference Unit (SIRU) system is reported. System development documents the system mechanization with the analytic formulation for fault detection and isolation processing structure; the hardware redundancy design and the individual modularity features; the computational structure and facilities; and the initial subsystem evaluation results.

  9. Detection of Helicobacter pylori DNA in inflamed dental pulp specimens from Japanese children and adolescents.

    PubMed

    Ogaya, Yuko; Nomura, Ryota; Watanabe, Yoshiyuki; Nakano, Kazuhiko

    2015-01-01

    The oral cavity has been implicated as a source of Helicobacter pylori infection in childhood. Various PCR methods have been used to detect H. pylori DNA in oral specimens with various detection rates reported. Such disparity in detection rates complicates the estimation of the true infection rate of H. pylori in the oral cavity. In the present study, we constructed a novel PCR system for H. pylori detection and used it to analyse oral specimens. Firstly, the nucleotide alignments of genes commonly used for H. pylori detection were compared using the complete genome information for 48 strains registered in the GenBank database. Candidate primer sets with an estimated amplification size of approximately 300-400 bp were selected, and the specificity and sensitivity of the detection system using each primer set were evaluated. Five sets of primers targeting ureA were considered appropriate, of which a single primer set was chosen for inclusion in the PCR system. The sensitivity of the system was considered appropriate and its detection limit established as one to ten cells per reaction. The novel PCR system was used to examine H. pylori distribution in oral specimens (40 inflamed pulp tissues, 40 saliva samples) collected from Japanese children, adolescents and young adults. PCR analysis revealed that the detection rate of H. pylori in inflamed pulp was 15 %, whereas no positive reaction was found in any of the saliva specimens. Taken together, our novel PCR system was found to be reliable for detecting H. pylori. The results obtained showed that H. pylori was detected in inflamed pulp but not saliva specimens, indicating that an infected root canal may be a reservoir for H. pylori. © 2015 The Authors.

  10. Local Area Defense (LAD) Demonstration

    DTIC Science & Technology

    2004-09-01

    Prozac ? Fentanyl? Institution, incident command, community drills - use of internet - digital photos of all victims to follow them through the system...and Budget, Paperwork Reduction Project (0704-0188), Washington, DC 20503 1. AGENCY USE ONLY 2. REPORT DATE 3. REPORT TYPE AND DATES COVERED (Leave...detection and rapid response system for local area defense using the University of Maryland Baltimore (UMB) Campus as a testbed. Additional goals includes

  11. Project report : road weather information system phase I

    DOT National Transportation Integrated Search

    2004-11-01

    The Alaska Department of Transportation & Public Facilities (ADOT&PF) initiated the first eight environmental sensor stations (ESS) in the Anchorage area, called the Road Weather Information System (RWIS) Phase I. The ESS are used to detect road weat...

  12. Investigation Of Alternative Displays For Side Collision Avoidance Systems, Final Report

    DOT National Transportation Integrated Search

    1996-12-01

    DRIVER-VEHICLE INTERFACE OR DVI, HUMAN FACTORS, DRIVER PREFERENCES, INTELLIGENT VEHICLE INITIATIVE OR IVI : SIDE COLLISION AVOIDANCE SYSTEMS (SCAS) ARE DESIGNED TO WARN OF IMPENDING COLLISIONS AND CAN DETECT NOT ONLY ADJACENT VEHICLES BUT VEHICLES...

  13. NegBio: a high-performance tool for negation and uncertainty detection in radiology reports.

    PubMed

    Peng, Yifan; Wang, Xiaosong; Lu, Le; Bagheri, Mohammadhadi; Summers, Ronald; Lu, Zhiyong

    2018-01-01

    Negative and uncertain medical findings are frequent in radiology reports, but discriminating them from positive findings remains challenging for information extraction. Here, we propose a new algorithm, NegBio, to detect negative and uncertain findings in radiology reports. Unlike previous rule-based methods, NegBio utilizes patterns on universal dependencies to identify the scope of triggers that are indicative of negation or uncertainty. We evaluated NegBio on four datasets, including two public benchmarking corpora of radiology reports, a new radiology corpus that we annotated for this work, and a public corpus of general clinical texts. Evaluation on these datasets demonstrates that NegBio is highly accurate for detecting negative and uncertain findings and compares favorably to a widely-used state-of-the-art system NegEx (an average of 9.5% improvement in precision and 5.1% in F1-score). https://github.com/ncbi-nlp/NegBio.

  14. Occurrence of antibiotics in wastewater treatment facilities in Wisconsin, USA

    USGS Publications Warehouse

    Karthikeyan, K.G.; Meyer, M.T.

    2006-01-01

    Samples from several wastewater treatment facilities in Wisconsin were screened for the presence of 21 antibiotic compounds. These facilities spanned a range of community size served (average daily flow from 0.0212 to 23.6 million gallons/day), secondary treatment processes, geographic locations across the state, and they discharged the treated effluents to both surface and ground waters (for ground water after a soil passage). A total of six antibiotic compounds were detected (1-5 compounds per site), including two sulfonamides (sulfamethazine, sulfamethoxazole), one tetracycline (tetracycline), fluoroquinolone (ciprofloxacin), macrolide (erythromycin-H2O) and trimethoprim. The frequency of detection of antibiotics was in the following order: tetracycline and trimethoprim (80%) > sulfamethoxazole (70%) > erythromycin-H2O (45%) > ciprofloxacin (40%) > sulfamethazine (10%). However, the soluble concentrations were in the parts-per-billion (ppb) range (??? 1.3 ??g/L), and importantly were unaffected by the size of the wastewater treatment facility. The concentrations detected were within an order of magnitude of those reported for similar systems in Europe and Canada: they were within a factor of two in comparison to those reported for Canada but generally lower relative to those measured in wastewater systems in Europe. Only sulfamethoxazole and tetracycline were detected in groundwater monitoring wells adjacent to the treatment systems. Future intensive wastewater monitoring programs in Wisconsin may be limited to the six antibiotic compounds detected in this study. ?? 2005 Elsevier B.V. All rights reserved.

  15. Occurrence of antibiotics in wastewater treatment facilities in Wisconsin, USA.

    PubMed

    Karthikeyan, K G; Meyer, Michael T

    2006-05-15

    Samples from several wastewater treatment facilities in Wisconsin were screened for the presence of 21 antibiotic compounds. These facilities spanned a range of community size served (average daily flow from 0.0212 to 23.6 million gallons/day), secondary treatment processes, geographic locations across the state, and they discharged the treated effluents to both surface and ground waters (for ground water after a soil passage). A total of six antibiotic compounds were detected (1-5 compounds per site), including two sulfonamides (sulfamethazine, sulfamethoxazole), one tetracycline (tetracycline), fluoroquinolone (ciprofloxacin), macrolide (erythromycin-H(2)O) and trimethoprim. The frequency of detection of antibiotics was in the following order: tetracycline and trimethoprim (80%)>sulfamethoxazole (70%)>erythromycin-H(2)O (45%)>ciprofloxacin (40%)>sulfamethazine (10%). However, the soluble concentrations were in the parts-per-billion (ppb) range (

  16. SU-F-T-471: Simulated External Beam Delivery Errors Detection with a Large Area Ion Chamber Transmission Detector

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hoffman, D; Dyer, B; Kumaran Nair, C

    Purpose: The Integral Quality Monitor (IQM), developed by iRT Systems GmbH (Koblenz, Germany) is a large-area, linac-mounted ion chamber used to monitor photon fluence during patient treatment. Our previous work evaluated the change of the ion chamber’s response to deviations from static 1×1 cm2 and 10×10 cm2 photon beams and other characteristics integral to use in external beam detection. The aim of this work is to simulate two external beam radiation delivery errors, quantify the detection of simulated errors and evaluate the reduction in patient harm resulting from detection. Methods: Two well documented radiation oncology delivery errors were selected formore » simulation. The first error was recreated by modifying a wedged whole breast treatment, removing the physical wedge and calculating the planned dose with Pinnacle TPS (Philips Radiation Oncology Systems, Fitchburg, WI). The second error was recreated by modifying a static-gantry IMRT pharyngeal tonsil plan to be delivered in 3 unmodulated fractions. A radiation oncologist evaluated the dose for simulated errors and predicted morbidity and mortality commiserate with the original reported toxicity, indicating that reported errors were approximately simulated. The ion chamber signal of unmodified treatments was compared to the simulated error signal and evaluated in Pinnacle TPS again with radiation oncologist prediction of simulated patient harm. Results: Previous work established that transmission detector system measurements are stable within 0.5% standard deviation (SD). Errors causing signal change greater than 20 SD (10%) were considered detected. The whole breast and pharyngeal tonsil IMRT simulated error increased signal by 215% and 969%, respectively, indicating error detection after the first fraction and IMRT segment, respectively. Conclusion: The transmission detector system demonstrated utility in detecting clinically significant errors and reducing patient toxicity/harm in simulated external beam delivery. Future work will evaluate detection of other smaller magnitude delivery errors.« less

  17. WE-G-BRA-01: Patient Safety and Treatment Quality Improvement Through Incident Learning: Experience of a Non-Academic Proton Therapy Center

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zheng, Y; Johnson, R; Zhao, L

    2015-06-15

    Purpose: Incident learning has been proven to improve patient safety and treatment quality in conventional radiation therapy. However, its application in proton therapy has not been reported yet to our knowledge. In this study, we report our experience in developing and implementation of an in-house incident learning system. Methods: An incident learning system was developed based on published principles and tailored for our clinical practice and available resource about 18 months ago. The system includes four layers of error detection and report: 1) dosimetry peer review; 2) physicist plan quality assurance (QA); 3) treatment delivery issue on call and record;more » and 4) other incident report. The first two layers of QA and report were mandatory for each treatment plan through easy-to-use spreadsheets that are only accessible by the dosimetry and physicist departments. The treatment delivery issues were recorded case by case by the on call physicist. All other incidents were reported through an online incident report system, which can be anonymous. The incident report includes near misses on planning and delivery, process deviation, machine issues, work flow and documentation. Periodic incident reviews were performed. Results: In total, about 116 errors were reported through dosimetry review, 137 errors through plan QA, 83 treatment issues through physics on call record, and 30 through the online incident report. Only 8 incidents (2.2%) were considered to have a clinical impact to patients, and the rest of errors were either detected before reaching patients or had negligible dosimetric impact (<5% dose variance). Personnel training & process improvements were implemented upon periodic incident review. Conclusion: An incident learning system can be helpful in personnel training, error reduction, and patient safety and treatment quality improvement. The system needs to be catered for each clinic’s practice and available resources. Incident and knowledge sharing among proton centers are encouraged.« less

  18. Development of luminol-N-hydroxyphthalimide chemiluminescence system for highly selective and sensitive detection of superoxide dismutase, uric acid and Co2.

    PubMed

    Saqib, Muhammad; Qi, Liming; Hui, Pan; Nsabimana, Anaclet; Halawa, Mohamed Ibrahim; Zhang, Wei; Xu, Guobao

    2018-01-15

    N-hydroxyphthalimide (NHPI), a well known reagent in organic synthesis and biochemical applications, has been developed as a stable and efficient chemiluminescence coreactant for the first time. It reacts with luminol much faster than N-hydroxysuccinimide, eliminating the need of a prereaction coil used in N-hydroxysuccinimide system. Without using prereaction coil, the chemiluminescence peak intensities of luminol-NHPI system are about 102 and 26 times greater than that of luminol-N-hydroxysuccinimide system and classical luminol-hydrogen peroxide system, respectively. The luminol-NHPI system achieves the highly sensitive detection of luminol (LOD = 70pM) and NHPI (LOD = 910nM). Based on their excellent quenching efficiencies, superoxide dismutase and uric acid are sensitively detected with LODs of 3ng/mL and 10pM, respectively. Co 2+ is also detected a LOD of 30pM by its remarkable enhancing effect. Noteworthily, our method is at least 4 orders of magnitude more sensitive than previously reported uric acid detection methods, and can detect uric acid in human urine and Co 2+ in tap and lake water real samples with excellent recoveries in the range of 96.35-102.70%. This luminol-NHPI system can be an important candidate for biochemical, clinical and environmental analysis. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Active Time-Domain Reflectometry for Unattended Safeguards Systems: FY16 Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tedeschi, Jonathan R.; Smith, Leon E.; Conrad, Ryan C.

    2016-10-21

    The International Atomic Energy Agency (IAEA) continues to expand its use of unattended measurement systems. An increasing number of systems and an expanding family of instruments create challenges in terms of deployment efficiency and the implementation of data authentication measures. Traditional data security measures, for example tamper-indicating (TI) conduit, are impractical for the long separation distances (often 100 meters or more) between unattended monitoring system (UMS) components. Pacific Northwest National Laboratory (PNNL) is studying the viability of active time-domain reflectometry (TDR) for the detection of cable tampering in unattended radiation detection systems. The instrument concept under investigation would allow formore » unmanned cable integrity measurements, remote surveillance reporting and locating of cable faults and/or tampers. This report describes PNNL’s FY16 progress and includes: an overview of the TDR methods under investigation; description of the TDR evaluation testbed developed by PNNL; development and testing of advanced signal processing algorithms to extract weak signals from relatively high noise levels; and initial testing of a laboratory prototype intended for IAEA UMS applications and based on a commercially available TDR module. Preliminary viability findings and recommendations for the next stage of development and testing are provided.« less

  20. Expanding veterinary biosurveillance in Washington, DC: The creation and utilization of an electronic-based online veterinary surveillance system.

    PubMed

    Hennenfent, Andrew; DelVento, Vito; Davies-Cole, John; Johnson-Clarke, Fern

    2017-03-01

    To enhance the early detection of emerging infectious diseases and bioterrorism events using companion animal-based surveillance. Washington, DC, small animal veterinary facilities (n=17) were surveyed to determine interest in conducting infectious disease surveillance. Using these results, an electronic-based online reporting system was developed and launched in August 2015 to monitor rates of canine influenza, canine leptospirosis, antibiotic resistant infections, canine parvovirus, and syndromic disease trends. Nine of the 10 facilities that responded expressed interest conducting surveillance. In September 2015, 17 canine parvovirus cases were reported. In response, a campaign encouraging regular veterinary preventative care was launched and featured on local media platforms. Additionally, during the system's first year of operation it detected 5 canine leptospirosis cases and 2 antibiotic resistant infections. No canine influenza cases were reported and syndromic surveillance compliance varied, peaking during National Special Security Events. Small animal veterinarians and the general public are interested in companion animal disease surveillance. The system described can serve as a model for establishing similar systems to monitor disease trends of public health importance in pet populations and enhance biosurveillance capabilities. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Usefulness of two- and three-dimensional transesophageal echocardiography in the assessment of proximal left coronary system compression by a paraprosthetic aortic valve abscess.

    PubMed

    Ahmad, Amier; McElwee, Samuel K; Jiang, Amy Z; Barssoum, Kirolos N; Elkaryoni, Ahmed E; Arisha, Mohammed J; Srialluri, Swetha; Seghatol, Frank; Nanda, Navin C

    2017-02-01

    Paraprosthetic aortic valve abscess represents a rare, but lethal complication of infective endocarditis. We report a case of proximal left coronary system compression by a paraprosthetic aortic valve abscess whose detection was augmented using live/real time three-dimensional transesophageal echocardiography. Our case illustrates the usefulness of combined two- and three-dimensional transesophageal echocardiography in detecting this finding. © 2017, Wiley Periodicals, Inc.

  2. Limited Connected Speech Experiment.

    DTIC Science & Technology

    1983-03-01

    male and twenty-five female speakers. This report describesT1 - s -"" real-time laboratory CSR system, the data base and training software de- O R M’ a...sounding word( s ). The end point detection class contains those errors in which the CSR system did not properly detect the beginning or end of the phrase...processing continues following end-of-file on the initialization ile. - s Operate in silent, rather than verbose, mode. Normally, each CSR com- mand

  3. A method for detecting and characterizing outbreaks of infectious disease from clinical reports.

    PubMed

    Cooper, Gregory F; Villamarin, Ricardo; Rich Tsui, Fu-Chiang; Millett, Nicholas; Espino, Jeremy U; Wagner, Michael M

    2015-02-01

    Outbreaks of infectious disease can pose a significant threat to human health. Thus, detecting and characterizing outbreaks quickly and accurately remains an important problem. This paper describes a Bayesian framework that links clinical diagnosis of individuals in a population to epidemiological modeling of disease outbreaks in the population. Computer-based diagnosis of individuals who seek healthcare is used to guide the search for epidemiological models of population disease that explain the pattern of diagnoses well. We applied this framework to develop a system that detects influenza outbreaks from emergency department (ED) reports. The system diagnoses influenza in individuals probabilistically from evidence in ED reports that are extracted using natural language processing. These diagnoses guide the search for epidemiological models of influenza that explain the pattern of diagnoses well. Those epidemiological models with a high posterior probability determine the most likely outbreaks of specific diseases; the models are also used to characterize properties of an outbreak, such as its expected peak day and estimated size. We evaluated the method using both simulated data and data from a real influenza outbreak. The results provide support that the approach can detect and characterize outbreaks early and well enough to be valuable. We describe several extensions to the approach that appear promising. Copyright © 2014 Elsevier Inc. All rights reserved.

  4. A Method for Detecting and Characterizing Outbreaks of Infectious Disease from Clinical Reports

    PubMed Central

    Cooper, Gregory F.; Villamarin, Ricardo; Tsui, Fu-Chiang (Rich); Millett, Nicholas; Espino, Jeremy U.; Wagner, Michael M.

    2014-01-01

    Outbreaks of infectious disease can pose a significant threat to human health. Thus, detecting and characterizing outbreaks quickly and accurately remains an important problem. This paper describes a Bayesian framework that links clinical diagnosis of individuals in a population to epidemiological modeling of disease outbreaks in the population. Computer-based diagnosis of individuals who seek healthcare is used to guide the search for epidemiological models of population disease that explain the pattern of diagnoses well. We applied this framework to develop a system that detects influenza outbreaks from emergency department (ED) reports. The system diagnoses influenza in individuals probabilistically from evidence in ED reports that are extracted using natural language processing. These diagnoses guide the search for epidemiological models of influenza that explain the pattern of diagnoses well. Those epidemiological models with a high posterior probability determine the most likely outbreaks of specific diseases; the models are also used to characterize properties of an outbreak, such as its expected peak day and estimated size. We evaluated the method using both simulated data and data from a real influenza outbreak. The results provide support that the approach can detect and characterize outbreaks early and well enough to be valuable. We describe several extensions to the approach that appear promising. PMID:25181466

  5. Imaging monitoring techniques applications in the transient gratings detection

    NASA Astrophysics Data System (ADS)

    Zhao, Qing-ming

    2009-07-01

    Experimental studies of Degenerate four-wave mixing (DFWM) in iodine vapor at atmospheric pressure and 0℃ and 25℃ are reported. The Laser-induced grating (LIG) studies are carried out by generating the thermal grating using a pulsed, narrow bandwidth, dye laser .A new image processing system for detecting forward DFWM spectroscopy on iodine vapor is reported. This system is composed of CCD camera, imaging processing card and the related software. With the help of the detecting system, phase matching can be easily achieved in the optical arrangement by crossing the two pumps and the probe as diagonals linking opposite corners of a rectangular box ,and providing a way to position the PhotoMultiplier Tube (PMT) . Also it is practical to know the effect of the pointing stability on the optical path by monitoring facula changing with the laser beam pointing and disturbs of the environment. Finally the effects of Photostability of dye laser on the ration of signal to noise in DFWM using forward geometries have been investigated in iodine vapor. This system makes it feasible that the potential application of FG-DFWM is used as a diagnostic tool in combustion research and environment monitoring.

  6. Nano-Electromechanical Systems: Displacement Detection and the Mechanical Single Electron Shuttle

    NASA Astrophysics Data System (ADS)

    Blick, R. H.; Beil, F. W.; Höhberger, E.; Erbe, A.; Weiss, C.

    For an introduction to nano-electromechanical systems we present measurements on nanomechanical resonators operating in the radio frequency range. We discuss in detail two different schemes of displacement detection for mechanical resonators, namely conventional reflection measurements of a probing signal and direct detection by capacitive coupling via a gate electrode. For capacitive detection we employ an on-chip preamplifier, which enables direct measurements of the resonator's disp lacement. We observe that the mechanical quality factor of the resonator depends on the detection technique applied, which is verified in model calculations and report on the detection of sub-harmonics. In the second part we extend our investigations to include transport of single electrons through an electron island on the tip of a nanomachined mechanical pendulum. The pendulum is operated by applying a modulating electromagnetic field in the range of 1 - 200 MHz, leading to mechanical oscillations between two laterally integrated source and drain contacts. Forming tunneling barriers the metallic tip shuttles single electrons from source to drain. The resulting tunneling current shows distinct features corresponding to the discrete mechanical eigenfrequencies of the pendulum. We report on measurements covering the temperature range from 300 K down to 4.2 K. The transport properties of the device are compared in detail to model calculations based on a Master-equation approach.

  7. Governance and One Health: Exploring the Impact of Federalism and Bureaucracy on Zoonotic Disease Detection and Reporting.

    PubMed

    Allen, Heather A

    2015-05-13

    The merits of One Health have been thoroughly described in the literature, but how One Health operates in the United States federal system of government is rarely discussed or analyzed. Through a comparative case-study approach, this research explores how federalism, bureaucratic behavior, and institutional design in the United States may influence zoonotic disease outbreak detection and reporting, a key One Health activity. Using theoretical and empirical literature, as well as a survey/interview instrument for individuals directly involved in a past zoonotic disease outbreak, the impacts of governance are discussed. As predicted in the theoretical literature, empirical findings suggest that federalism, institutional design, and bureaucracy may play a role in facilitating or impeding zoonotic disease outbreak detection and reporting. Regulatory differences across states as well as compartmentalization of information within agencies may impede disease detection. However, the impact may not always be negative: bureaucracies can also be adaptive; federalism allows states important opportunities for innovation. While acknowledging there are many other factors that also matter in zoonotic disease detection and reporting, this research is one of the first attempts to raise awareness in the literature and stimulate discussion on the intersection of governance and One Health.

  8. Load-cell based characterization system for a "Violin-Mode" shadow-sensor in advanced LIGO suspensions

    NASA Astrophysics Data System (ADS)

    Lockerbie, N. A.; Tokmakov, K. V.

    2016-07-01

    The background to this work was a prototype shadow sensor, which was designed for retro-fitting to an advanced LIGO (Laser Interferometer Gravitational wave Observatory) test-mass/mirror suspension, in which 40 kg test-mass/mirrors are each suspended by four approximately 600 mm long by 0.4 mm diameter fused-silica suspension fibres. The shadow sensor comprised a LED source of Near InfraRed (NIR) radiation and a rectangular silicon photodiode detector, which, together, were to bracket the fibre under test. The aim was to detect transverse Violin-Mode resonances in the suspension fibres. Part of the testing procedure involved tensioning a silica fibre sample and translating it transversely through the illuminating NIR beam, so as to measure the DC responsivity of the detection system to fibre displacement. However, an equally important part of the procedure, reported here, was to keep the fibre under test stationary within the beam, whilst trying to detect low-level AC Violin-Mode resonances excited on the fibre, in order to confirm the primary function of the sensor. Therefore, a tensioning system, incorporating a load-cell readout, was built into the test fibre's holder. The fibre then was excited by a signal generator, audio power amplifier, and distant loudspeaker, and clear resonances were detected. A theory for the expected fundamental resonant frequency as a function of fibre tension was developed and is reported here, and this theory was found to match closely with the detected resonant frequencies as they varied with tension. Consequently, the resonances seen were identified as being proper Violin-Mode fundamental resonances of the fibre, and the operation of the Violin-Mode detection system was validated.

  9. Load-cell based characterization system for a "Violin-Mode" shadow-sensor in advanced LIGO suspensions.

    PubMed

    Lockerbie, N A; Tokmakov, K V

    2016-07-01

    The background to this work was a prototype shadow sensor, which was designed for retro-fitting to an advanced LIGO (Laser Interferometer Gravitational wave Observatory) test-mass/mirror suspension, in which 40 kg test-mass/mirrors are each suspended by four approximately 600 mm long by 0.4 mm diameter fused-silica suspension fibres. The shadow sensor comprised a LED source of Near InfraRed (NIR) radiation and a rectangular silicon photodiode detector, which, together, were to bracket the fibre under test. The aim was to detect transverse Violin-Mode resonances in the suspension fibres. Part of the testing procedure involved tensioning a silica fibre sample and translating it transversely through the illuminating NIR beam, so as to measure the DC responsivity of the detection system to fibre displacement. However, an equally important part of the procedure, reported here, was to keep the fibre under test stationary within the beam, whilst trying to detect low-level AC Violin-Mode resonances excited on the fibre, in order to confirm the primary function of the sensor. Therefore, a tensioning system, incorporating a load-cell readout, was built into the test fibre's holder. The fibre then was excited by a signal generator, audio power amplifier, and distant loudspeaker, and clear resonances were detected. A theory for the expected fundamental resonant frequency as a function of fibre tension was developed and is reported here, and this theory was found to match closely with the detected resonant frequencies as they varied with tension. Consequently, the resonances seen were identified as being proper Violin-Mode fundamental resonances of the fibre, and the operation of the Violin-Mode detection system was validated.

  10. Load-cell based characterization system for a “Violin-Mode” shadow-sensor in advanced LIGO suspensions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lockerbie, N. A.; Tokmakov, K. V.

    The background to this work was a prototype shadow sensor, which was designed for retro-fitting to an advanced LIGO (Laser Interferometer Gravitational wave Observatory) test-mass/mirror suspension, in which 40 kg test-mass/mirrors are each suspended by four approximately 600 mm long by 0.4 mm diameter fused-silica suspension fibres. The shadow sensor comprised a LED source of Near InfraRed (NIR) radiation and a rectangular silicon photodiode detector, which, together, were to bracket the fibre under test. The aim was to detect transverse Violin-Mode resonances in the suspension fibres. Part of the testing procedure involved tensioning a silica fibre sample and translating itmore » transversely through the illuminating NIR beam, so as to measure the DC responsivity of the detection system to fibre displacement. However, an equally important part of the procedure, reported here, was to keep the fibre under test stationary within the beam, whilst trying to detect low-level AC Violin-Mode resonances excited on the fibre, in order to confirm the primary function of the sensor. Therefore, a tensioning system, incorporating a load-cell readout, was built into the test fibre’s holder. The fibre then was excited by a signal generator, audio power amplifier, and distant loudspeaker, and clear resonances were detected. A theory for the expected fundamental resonant frequency as a function of fibre tension was developed and is reported here, and this theory was found to match closely with the detected resonant frequencies as they varied with tension. Consequently, the resonances seen were identified as being proper Violin-Mode fundamental resonances of the fibre, and the operation of the Violin-Mode detection system was validated.« less

  11. Trace Contraband Detection Field-Test by the South Texas Specialized Crimes and Narcotics Task Force

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hannum, David W.; Shannon, Gary W.

    This report describes the collaboration between the South Texas Specialized Crimes and Narcotics Task Force (STSCNTF) and Sandia National Laboratories (SNL) in a field test that provided prototype hand-held trace detection technology for use in counter-drug operations. The National Institute of Justice (NIJ)/National Law Enforcement and Corrections Technology Center (NLECTC)/Border Research and Technology Center (BRTC) was contacted by STSCNTF for assistance in obtaining cutting-edge technology. The BRTC created a pilot project for Sandia National Laboratories (SNL) and the STSCNTF for the use of SNL’s Hound, a hand-held sample collection and preconcentration system that, when combined with a commercial chemical detector,more » can be used for the trace detection of illicit drugs and explosives. The STSCNTF operates in an area of high narcotics trafficking where methods of concealment make the detection of narcotics challenging. Sandia National Laboratories’ (SNL) Contraband Detection Department personnel provided the Hound system hardware and operational training. The Hound system combines the GE VaporTracer2, a hand-held commercial chemical detector, with an SNL-developed sample collection and preconcentration system. The South Texas Task force reported a variety of successes, including identification of a major shipment of methamphetamines, the discovery of hidden compartments in vehicles that contained illegal drugs and currency used in drug deals, and the identification of a suspect in a nightclub shooting. The main advantage of the hand-held trace detection unit is its ability to quickly identify the type of chemical (drugs or explosives) without a long lag time for laboratory analysis, which is the most common analysis method for current law enforcement procedures.« less

  12. Label-free optical detection of action potential in mammalian neurons (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Batabyal, Subrata; Satpathy, Sarmishtha; Bui, Loan; Kim, Young-Tae; Mohanty, Samarendra K.; Davé, Digant P.

    2017-02-01

    Electrophysiology techniques are the gold standard in neuroscience for studying functionality of a single neuron to a complex neuronal network. However, electrophysiology techniques are not flawless, they are invasive nature, procedures are cumbersome to implement with limited capability of being used as a high-throughput recording system. Also, long term studies of neuronal functionality with aid of electrophysiology is not feasible. Non-invasive stimulation and detection of neuronal electrical activity has been a long standing goal in neuroscience. Introduction of optogenetics has ushered in the era of non-invasive optical stimulation of neurons, which is revolutionizing neuroscience research. Optical detection of neuronal activity that is comparable to electro-physiology is still elusive. A number of optical techniques have been reported recording of neuronal electrical activity but none is capable of reliably measuring action potential spikes that is comparable to electro-physiology. Optical detection of action potential with voltage sensitive fluorescent reporters are potential alternatives to electrophysiology techniques. The heavily rely on secondary reporters, which are often toxic in nature with background fluorescence, with slow response and low SNR making them far from ideal. The detection of one shot (without averaging)-single action potential in a true label-free way has been elusive so far. In this report, we demonstrate the optical detection of single neuronal spike in a cultured mammalian neuronal network without using any exogenous labels. To the best of our knowledge, this is the first demonstration of label free optical detection of single action potentials in a mammalian neuronal network, which was achieved using a high-speed phase sensitive interferometer. We have carried out stimulation and inhibition of neuronal firing using Glutamate and Tetrodotoxin respectively to demonstrate the different outcome (stimulation and inhibition) revealed in optical signal. We hypothesize that the interrogating optical beam is modulated during neuronal firing by electro-motility driven membrane fluctuation in conjunction with electrical wave propagation in cellular system.

  13. Performance metrics for state-of-the-art airborne magnetic and electromagnetic systems for mapping and detection of unexploded ordnance

    NASA Astrophysics Data System (ADS)

    Doll, William E.; Bell, David T.; Gamey, T. Jeffrey; Beard, Les P.; Sheehan, Jacob R.; Norton, Jeannemarie

    2010-04-01

    Over the past decade, notable progress has been made in the performance of airborne geophysical systems for mapping and detection of unexploded ordnance in terrestrial and shallow marine environments. For magnetometer systems, the most significant improvements include development of denser magnetometer arrays and vertical gradiometer configurations. In prototype analyses and recent Environmental Security Technology Certification Program (ESTCP) assessments using new production systems the greatest sensitivity has been achieved with a vertical gradiometer configuration, despite model-based survey design results which suggest that dense total-field arrays would be superior. As effective as magnetometer systems have proven to be at many sites, they are inadequate at sites where basalts and other ferrous geologic formations or soils produce anomalies that approach or exceed those of target ordnance items. Additionally, magnetometer systems are ineffective where detection of non-ferrous ordnance items is of primary concern. Recent completion of the Battelle TEM-8 airborne time-domain electromagnetic system represents the culmination of nearly nine years of assessment and development of airborne electromagnetic systems for UXO mapping and detection. A recent ESTCP demonstration of this system in New Mexico showed that it was able to detect 99% of blind-seeded ordnance items, 81mm and larger, and that it could be used to map in detail a bombing target on a basalt flow where previous airborne magnetometer surveys had failed. The probability of detection for the TEM-8 in the blind-seeded study area was better than that reported for a dense-array total-field magnetometer demonstration of the same blind-seeded site, and the TEM-8 system successfully detected these items with less than half as many anomaly picks as the dense-array total-field magnetometer system.

  14. Real-time diagnostics for a reusable rocket engine

    NASA Technical Reports Server (NTRS)

    Guo, T. H.; Merrill, W.; Duyar, A.

    1992-01-01

    A hierarchical, decentralized diagnostic system is proposed for the Real-Time Diagnostic System component of the Intelligent Control System (ICS) for reusable rocket engines. The proposed diagnostic system has three layers of information processing: condition monitoring, fault mode detection, and expert system diagnostics. The condition monitoring layer is the first level of signal processing. Here, important features of the sensor data are extracted. These processed data are then used by the higher level fault mode detection layer to do preliminary diagnosis on potential faults at the component level. Because of the closely coupled nature of the rocket engine propulsion system components, it is expected that a given engine condition may trigger more than one fault mode detector. Expert knowledge is needed to resolve the conflicting reports from the various failure mode detectors. This is the function of the diagnostic expert layer. Here, the heuristic nature of this decision process makes it desirable to use an expert system approach. Implementation of the real-time diagnostic system described above requires a wide spectrum of information processing capability. Generally, in the condition monitoring layer, fast data processing is often needed for feature extraction and signal conditioning. This is usually followed by some detection logic to determine the selected faults on the component level. Three different techniques are used to attack different fault detection problems in the NASA LeRC ICS testbed simulation. The first technique employed is the neural network application for real-time sensor validation which includes failure detection, isolation, and accommodation. The second approach demonstrated is the model-based fault diagnosis system using on-line parameter identification. Besides these model based diagnostic schemes, there are still many failure modes which need to be diagnosed by the heuristic expert knowledge. The heuristic expert knowledge is implemented using a real-time expert system tool called G2 by Gensym Corp. Finally, the distributed diagnostic system requires another level of intelligence to oversee the fault mode reports generated by component fault detectors. The decision making at this level can best be done using a rule-based expert system. This level of expert knowledge is also implemented using G2.

  15. LEAK DETECTION AND WIRELESS TELEMETRY FOR WATER DISTRIBUTION AND SEWERAGE SYSTEMS - PHASE I

    EPA Science Inventory

    According to the study EPA 2000 Community Water System Survey Data on Pipe Assets, the infrastructure for water distribution and sewerage systems is aging and requires replacement.  In addition, in EPA’s September 2002 report Clean Water and Drinking Water Infr...

  16. Operation Of The X-29A Digital Flight-Control System

    NASA Technical Reports Server (NTRS)

    Chacon, Vince; Mcbride, David

    1990-01-01

    Report reviews program of testing and evaluation of digital flight-control system for X-29A airplane, with emphasis on operation during tests. Topics include design of system, special electronic testing equipment designed to aid in daily operations, and aspects of testing, including detection of faults.

  17. An Intelligent Tutor for Intrusion Detection on Computer Systems.

    ERIC Educational Resources Information Center

    Rowe, Neil C.; Schiavo, Sandra

    1998-01-01

    Describes an intelligent tutor incorporating a program using artificial-intelligence planning methods to generate realistic audit files reporting actions of simulated users and intruders of a UNIX system, and a program simulating the system afterwards that asks students to inspect the audit and fix problems. Experiments show that students using…

  18. Health Monitor for Multitasking, Safety-Critical, Real-Time Software

    NASA Technical Reports Server (NTRS)

    Zoerner, Roger

    2011-01-01

    Health Manager can detect Bad Health prior to a failure occurring by periodically monitoring the application software by looking for code corruption errors, and sanity-checking each critical data value prior to use. A processor s memory can fail and corrupt the software, or the software can accidentally write to the wrong address and overwrite the executing software. This innovation will continuously calculate a checksum of the software load to detect corrupted code. This will allow a system to detect a failure before it happens. This innovation monitors each software task (thread) so that if any task reports "bad health," or does not report to the Health Manager, the system is declared bad. The Health Manager reports overall system health to the outside world by outputting a square wave signal. If the square wave stops, this indicates that system health is bad or hung and cannot report. Either way, "bad health" can be detected, whether caused by an error, corrupted data, or a hung processor. A separate Health Monitor Task is started and run periodically in a loop that starts and stops pending on a semaphore. Each monitored task registers with the Health Manager, which maintains a count for the task. The registering task must indicate if it will run more or less often than the Health Manager. If the task runs more often than the Health Manager, the monitored task calls a health function that increments the count and verifies it did not go over max-count. When the periodic Health Manager runs, it verifies that the count did not go over the max-count and zeroes it. If the task runs less often than the Health Manager, the periodic Health Manager will increment the count. The monitored task zeroes the count, and both the Health Manager and monitored task verify that the count did not go over the max-count.

  19. Comparison of the KSC-ER Cloud-to-Ground Lightning Surveillance System (CGLSS) and the U.S. National Lightning Detection Network(TradeMark)(NLDN)

    NASA Technical Reports Server (NTRS)

    Ward, Jennifer G.; Cummins, Kenneth L.; Krider, E. Philip

    2007-01-01

    The NASA Kennedy Space Center (KSC) and Air Force Eastern Range (ER) use data from two cloud-to-ground lightning detection networks, CGLSS and NLDN, during ground and launch operations at the KSC-ER. For these applications, it is very important to understand the location accuracy and detection efficiency of each network near the KSC-ER. If a cloud-to-ground (CG) lightning strike is missed or mis-located by even a small amount, the result could have significant safety implications, require expensive retests, or create unnecessary delays or scrubs in launches. Therefore, it is important to understand the performance of each lightning detection system in considerable detail. To evaluate recent upgrades in the CGLSS sensors in 2000 and the entire NLDN in 2002- 2003, we have compared. measurements provided by these independent networks in the summers of 2005 and 2006. Our analyses have focused on the fraction of first strokes reported individually and in-common by each network (flash detection efficiency), the spatial separation between the strike points reported by both networks (relative location accuracy), and the values of the estimated peak current, Ip, reported by each network. The results within 100 km of the KSC-ER show that the networks produce very similar values of Ip (except for a small scaling difference) and that the relative location accuracy is consistent with model estimates that give median values of 200-300m for the CGLSS and 600-700m for the NLDN in the region of the KSC-ER. Because of differences in the network geometries and sensor gains, the NLDN does not report 10-20% of the flashes that have a low Ip (2 kA < |Ip| < 16 kA), both networks report 99 % of the flashes that have intermediate values of Ip (16< |Ip| < 50 kA), and the CGLSS fails to report 20-30% of the high-current events (|Ip| >=0 kA).

  20. Discovery of a Jupiter/Saturn analog with gravitational microlensing.

    PubMed

    Gaudi, B S; Bennett, D P; Udalski, A; Gould, A; Christie, G W; Maoz, D; Dong, S; McCormick, J; Szymanski, M K; Tristram, P J; Nikolaev, S; Paczynski, B; Kubiak, M; Pietrzynski, G; Soszynski, I; Szewczyk, O; Ulaczyk, K; Wyrzykowski, L; Depoy, D L; Han, C; Kaspi, S; Lee, C-U; Mallia, F; Natusch, T; Pogge, R W; Park, B-G; Abe, F; Bond, I A; Botzler, C S; Fukui, A; Hearnshaw, J B; Itow, Y; Kamiya, K; Korpela, A V; Kilmartin, P M; Lin, W; Masuda, K; Matsubara, Y; Motomura, M; Muraki, Y; Nakamura, S; Okumura, T; Ohnishi, K; Rattenbury, N J; Sako, T; Saito, To; Sato, S; Skuljan, L; Sullivan, D J; Sumi, T; Sweatman, W L; Yock, P C M; Albrow, M D; Allan, A; Beaulieu, J-P; Burgdorf, M J; Cook, K H; Coutures, C; Dominik, M; Dieters, S; Fouqué, P; Greenhill, J; Horne, K; Steele, I; Tsapras, Y; Chaboyer, B; Crocker, A; Frank, S; Macintosh, B

    2008-02-15

    Searches for extrasolar planets have uncovered an astonishing diversity of planetary systems, yet the frequency of solar system analogs remains unknown. The gravitational microlensing planet search method is potentially sensitive to multiple-planet systems containing analogs of all the solar system planets except Mercury. We report the detection of a multiple-planet system with microlensing. We identify two planets with masses of approximately 0.71 and approximately 0.27 times the mass of Jupiter and orbital separations of approximately 2.3 and approximately 4.6 astronomical units orbiting a primary star of mass approximately 0.50 solar mass at a distance of approximately 1.5 kiloparsecs. This system resembles a scaled version of our solar system in that the mass ratio, separation ratio, and equilibrium temperatures of the planets are similar to those of Jupiter and Saturn. These planets could not have been detected with other techniques; their discovery from only six confirmed microlensing planet detections suggests that solar system analogs may be common.

  1. Phase II: Automated System for Aneuploidy Detection in Sperm Final Report CRADA No. TC-1554-98

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wyrobek, W. J.; Dunlay, R. T.

    This was a collaborative effort between the University of California, Lawrence Livermore National Laboratory (LLNL) and Cellomics, Inc. (formerly BioDx and Biological Detection, Inc.) to develop an automated system for detecting human sperm aneuploidy. Aneuploidy (an abnormal number of chromosomes) is one of the major categories of chromosomally abnormal sperm, which results in chromosomally defective pregnancies and babies. An automated system would be used for testing the effects of toxic agents and for other research and clinical applications. This collaborated effort was funded by a National Institutes of Environmental Health Services, Phase II, Small Business Innovation Research Program (SBIR) grantmore » to Cellornics (Contract No. N44-ES-82004).« less

  2. Automatic detection, tracking and sensor integration

    NASA Astrophysics Data System (ADS)

    Trunk, G. V.

    1988-06-01

    This report surveys the state of the art of automatic detection, tracking, and sensor integration. In the area of detection, various noncoherent integrators such as the moving window integrator, feedback integrator, two-pole filter, binary integrator, and batch processor are discussed. Next, the three techniques for controlling false alarms, adapting thresholds, nonparametric detectors, and clutter maps are presented. In the area of tracking, a general outline is given of a track-while-scan system, and then a discussion is presented of the file system, contact-entry logic, coordinate systems, tracking filters, maneuver-following logic, tracking initiating, track-drop logic, and correlation procedures. Finally, in the area of multisensor integration the problems of colocated-radar integration, multisite-radar integration, radar-IFF integration, and radar-DF bearing strobe integration are treated.

  3. Automated Technology for In-home Fall Risk Assessment and Detection Sensor System

    PubMed Central

    Rantz, Marilyn J.; Skubic, Marjorie; Abbott, Carmen; Galambos, Colleen; Pak, Youngju; Ho, Dominic K.C.; Stone, Erik E.; Rui, Liyang; Back, Jessica; Miller, Steven J.

    2013-01-01

    Falls are a major problem for older adults. A continuous, unobtrusive, environmentally mounted in-home monitoring system that automatically detects when falls have occurred or when the risk of falling is increasing could alert health care providers and family members so they could intervene to improve physical function or mange illnesses that are precipitating falls. Researchers at the University of Missouri (MU)Center for Eldercare and Rehabilitation Technology are testing such sensor systems for fall risk assessment and detection in older adults’ apartments in a senior living community. Initial results comparing ground truth fall risk assessment data and GAITRite gait parameters with gait parameters captured from Mircosoft Kinect and Pulse-Dopplar radar are reported. PMID:23675644

  4. Direct molecular testing to assess the incidence of meningococcal and other bacterial causes of meningitis among persons reported with unspecified bacterial meningitis.

    PubMed

    Ramautar, Arianne E; Halse, Tanya A; Arakaki, Lola; Antwi, Mike; Del Rosso, Paula; Dorsinville, Marie; Nazarian, Elizabeth; Steiner-Sichel, Linda; Lee, Lillian; Dickinson, Michelle; Wroblewski, Danielle; Dumas, Nellie; Musser, Kimberlee; Isaac, Beth; Rakeman, Jennifer; Weiss, Don

    2015-11-01

    Confirmed and probable cases of invasive Neisseria meningitidis (Nm) infection are reportable in New York City. We conducted a study to identify Nm among culture-negative reports of bacterial and viral meningitis. During the study period, 262 reports of suspected meningitis were eligible. Cerebrospinal fluid (CSF) specimens from 138 patients were obtained for testing. No Nm cases were detected. Results from real-time polymerase chain reaction and 16S on CSF specimens were concordant with hospital microbiology findings in 80%; however, other pathogenic organisms were detected in 14 culture-negative specimens. New York City's surveillance system appears to be effective at capturing cases of Nm meningitis. Nucleic acid testing is useful for detecting the presence of bacterial DNA when antibiotic therapy precedes lumbar puncture or bacterial cultures are negative. It remains unanswered whether culture-negative cases of Nm bacteremia are being missed by reportable disease surveillance. Copyright © 2015 Elsevier Inc. All rights reserved.

  5. A Discovery of a Candidate Companion to a Transiting System KOI-94: A Direct Imaging Study for a Possibility of a False Positive

    NASA Technical Reports Server (NTRS)

    Takahashi, Yasuhiro; Narita, Norio; Hirano, Teruyuki; Kuzuhara, Masayuki; Tamura, Motohide; Kudo, Tomoyuki; Kusakabe, Nobuhiko; Hashimoto, Jun; Sato, Bun'ei; Abe, Lyu; hide

    2013-01-01

    We report a discovery of a companion candidate around one of Kepler Objects of Interest (KOIs), KOI-94, and results of our quantitative investigation of the possibility that planetary candidates around KOI-94 are false positives. KOI-94 has a planetary system in which four planetary detections have been reported by Kepler, suggesting that this system is intriguing to study the dynamical evolutions of planets. However, while two of those detections (KOI-94.01 and 03) have been made robust by previous observations, the others (KOI-94.02 and 04) are marginal detections, for which future confirmations with various techniques are required. We have conducted high-contrast direct imaging observations with Subaru/HiCIAO in H band and detected a faint object located at a separation of approximately 0.6 sec from KOI-94. The object has a contrast of approximately 1 × 10(exp -3) in H band, and corresponds to an M type star on the assumption that the object is at the same distance of KOI-94. Based on our analysis, KOI-94.02 is likely to be a real planet because of its transit depth, while KOI-94.04 can be a false positive due to the companion candidate. The success in detecting the companion candidate suggests that high-contrast direct imaging observations are important keys to examine false positives of KOIs. On the other hand, our transit light curve reanalyses lead to a better period estimate of KOI-94.04 than that on the KOI catalogue and show that the planetary candidate has the same limb darkening parameter value as the other planetary candidates in the KOI-94 system, suggesting that KOI-94.04 is also a real planet in the system.

  6. Underwater detection by using ultrasonic sensor

    NASA Astrophysics Data System (ADS)

    Bakar, S. A. A.; Ong, N. R.; Aziz, M. H. A.; Alcain, J. B.; Haimi, W. M. W. N.; Sauli, Z.

    2017-09-01

    This paper described the low cost implementation of hardware and software in developing the system of ultrasonic which can visualize the feedback of sound in the form of measured distance through mobile phone and monitoring the frequency of detection by using real time graph of Java application. A single waterproof transducer of JSN-SR04T had been used to determine the distance of an object based on operation of the classic pulse echo detection method underwater. In this experiment, the system was tested by placing the housing which consisted of Arduino UNO, Bluetooth module of HC-06, ultrasonic sensor and LEDs at the top of the box and the transducer was immersed in the water. The system which had been tested for detection in vertical form was found to be capable of reporting through the use of colored LEDs as indicator to the relative proximity of object distance underwater form the sensor. As a conclusion, the system can detect the presence of an object underwater within the range of ultrasonic sensor and display the measured distance onto the mobile phone and the real time graph had been successfully generated.

  7. Transit bus stop pedestrian warning application : architecture and design : final report.

    DOT National Transportation Integrated Search

    2017-02-28

    This document describes the Draft System Architecture and Design for the Transit Bus Stop Pedestrian Warning (TSPW) application including the design for the pedestrian detection system and DSRC radio to be deployed at transit stops and includes detai...

  8. Design of a modular digital computer system

    NASA Technical Reports Server (NTRS)

    1973-01-01

    A design tradeoff study is reported for a modular spaceborne computer system that is responsive to many mission types and phases. The computer uses redundancy to maximize reliability, and multiprocessing to maximize processing capacity. Fault detection and recovery features provide optimal reliability.

  9. Remote health monitoring system for detecting cardiac disorders.

    PubMed

    Bansal, Ayush; Kumar, Sunil; Bajpai, Anurag; Tiwari, Vijay N; Nayak, Mithun; Venkatesan, Shankar; Narayanan, Rangavittal

    2015-12-01

    Remote health monitoring system with clinical decision support system as a key component could potentially quicken the response of medical specialists to critical health emergencies experienced by their patients. A monitoring system, specifically designed for cardiac care with electrocardiogram (ECG) signal analysis as the core diagnostic technique, could play a vital role in early detection of a wide range of cardiac ailments, from a simple arrhythmia to life threatening conditions such as myocardial infarction. The system that the authors have developed consists of three major components, namely, (a) mobile gateway, deployed on patient's mobile device, that receives 12-lead ECG signals from any ECG sensor, (b) remote server component that hosts algorithms for accurate annotation and analysis of the ECG signal and (c) point of care device of the doctor to receive a diagnostic report from the server based on the analysis of ECG signals. In the present study, their focus has been toward developing a system capable of detecting critical cardiac events well in advance using an advanced remote monitoring system. A system of this kind is expected to have applications ranging from tracking wellness/fitness to detection of symptoms leading to fatal cardiac events.

  10. Fuzzy Comprehensive Evaluation (FCE) in Military Decision Support Processes

    DTIC Science & Technology

    2013-12-01

    detection in military aircraft (Brotherton & Johnson, 2001). Today, as reported by the international journal Advances in Fuzzy Systems (2013), as of March... detection for advanced military aircraft using neural networks. In IEEE Proceedings Aerospace Conference, 2001, 6, 3113–3123. Cheng, C . H. (1996... C .   OBJECTIVE ................................................................................................... 3   II.   THE FUZZY

  11. 75 FR 68693 - Airworthiness Directives; Airbus Model A380-800 Series Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-09

    ... may lead to a degraded leak detection capability have been reported. In case of hot air leakage, the... inspection in production and on in-service aircraft, a number of OverHeat Detection System (OHDS... could allow undetected leakage of bleed air from the hot engine/auxiliary power unit causing damage to...

  12. Automated System for Aneuploidy Detection in Sperm Final Report CRADA No. TC-1364-96: Phase I SBIR

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wyrobek, A. J.; Dunlay, R. T.

    This project was a relationship between Lawrence Livermore National Laboratory (LLNL) and Biological Detection, Inc. (now known as Cellomics, Inc.) It was funded as a Phase I SBIR from the National Institutes of Health (NIH) awarded to Cellomics, Inc. with a subcontract to LLNL.

  13. A unified metabolism for Mars: A new approach developed from research on extraterrestrial life detection by enzymatically induced exchange of O 18

    NASA Technical Reports Server (NTRS)

    1972-01-01

    A general graded life detection approach ranging from environmental and in situ observations to specific metabolic experiments on Mars is reported. A zero dead volume leak and computer mediated data acquisition system is also discussed. Soil analyses were also conducted.

  14. Low-Cost ASDE Evaluation Report: Raytheon Marine (Phase I) Radar at MKE (ARPA M345O/18CPX-19), Volume I.

    DOT National Transportation Integrated Search

    1996-07-31

    The FAA has identified the Airport Surface Detection Equipment as a radar system that aids air traffic controllers in low visibility conditions to detect surface radar targets and sequence aircraft movement on active runways. Though 35 major U.S. air...

  15. A new tool for the rapid remote detection of leaks from subsea pipelines during remotely operated vehicle inspections

    NASA Astrophysics Data System (ADS)

    McStay, D.; McIlroy, J.; Forte, A.; Lunney, F.; Greenway, T.; Thabeth, K.; Dean, G.

    2005-06-01

    A new 2000 m depth rated subsea sensor that can effectively, rapidly and remotely detect leaks of fluorescein dye, leak detection chemicals and hydraulic fluids from underwater structures is reported. The system utilizes ultra-bright LED technology to project a structured beam of light, at a wavelength suitable to excite the fluorescence of the target material, into the water column. The resultant fluorescence is collected and digital signal processing used to extract the intensity. The system is capable of detecting ppm concentrations of fluorescein at a range of 2.5 m in water in real time. The ability to stand-off from subsea structures, while rapidly detecting the chemicals makes the system highly suited to subsea leak inspections with remotely operated vehicles or autonomous underwater vehicles, as it allows the vehicles to be flown quickly and safely over the structure to be inspected. This increases both the speed and effectiveness of the inspection. The remote detection capability is also highly effective for probing complex underwater structures. The system has been successfully used in real subsea survey applications and has been found to be effective, user friendly and to dramatically reduce inspection times and hence costs.

  16. Software-implemented fault insertion: An FTMP example

    NASA Technical Reports Server (NTRS)

    Czeck, Edward W.; Siewiorek, Daniel P.; Segall, Zary Z.

    1987-01-01

    This report presents a model for fault insertion through software; describes its implementation on a fault-tolerant computer, FTMP; presents a summary of fault detection, identification, and reconfiguration data collected with software-implemented fault insertion; and compares the results to hardware fault insertion data. Experimental results show detection time to be a function of time of insertion and system workload. For the fault detection time, there is no correlation between software-inserted faults and hardware-inserted faults; this is because hardware-inserted faults must manifest as errors before detection, whereas software-inserted faults immediately exercise the error detection mechanisms. In summary, the software-implemented fault insertion is able to be used as an evaluation technique for the fault-handling capabilities of a system in fault detection, identification and recovery. Although the software-inserted faults do not map directly to hardware-inserted faults, experiments show software-implemented fault insertion is capable of emulating hardware fault insertion, with greater ease and automation.

  17. A preliminary design for flight testing the FINDS algorithm

    NASA Technical Reports Server (NTRS)

    Caglayan, A. K.; Godiwala, P. M.

    1986-01-01

    This report presents a preliminary design for flight testing the FINDS (Fault Inferring Nonlinear Detection System) algorithm on a target flight computer. The FINDS software was ported onto the target flight computer by reducing the code size by 65%. Several modifications were made to the computational algorithms resulting in a near real-time execution speed. Finally, a new failure detection strategy was developed resulting in a significant improvement in the detection time performance. In particular, low level MLS, IMU and IAS sensor failures are detected instantaneously with the new detection strategy, while accelerometer and the rate gyro failures are detected within the minimum time allowed by the information generated in the sensor residuals based on the point mass equations of motion. All of the results have been demonstrated by using five minutes of sensor flight data for the NASA ATOPS B-737 aircraft in a Microwave Landing System (MLS) environment.

  18. A dual-processor multi-frequency implementation of the FINDS algorithm

    NASA Technical Reports Server (NTRS)

    Godiwala, Pankaj M.; Caglayan, Alper K.

    1987-01-01

    This report presents a parallel processing implementation of the FINDS (Fault Inferring Nonlinear Detection System) algorithm on a dual processor configured target flight computer. First, a filter initialization scheme is presented which allows the no-fail filter (NFF) states to be initialized using the first iteration of the flight data. A modified failure isolation strategy, compatible with the new failure detection strategy reported earlier, is discussed and the performance of the new FDI algorithm is analyzed using flight recorded data from the NASA ATOPS B-737 aircraft in a Microwave Landing System (MLS) environment. The results show that low level MLS, IMU, and IAS sensor failures are detected and isolated instantaneously, while accelerometer and rate gyro failures continue to take comparatively longer to detect and isolate. The parallel implementation is accomplished by partitioning the FINDS algorithm into two parts: one based on the translational dynamics and the other based on the rotational kinematics. Finally, a multi-rate implementation of the algorithm is presented yielding significantly low execution times with acceptable estimation and FDI performance.

  19. Navy Needs to Establish Effective Metrics to Achieve Desired Outcomes for SPY1 Radar Sustainment (Redacted)

    DTIC Science & Technology

    2016-08-01

    a series on SPY-1 radar spare parts. The SPY-1 radar is an advanced , automatic detect and track radar system . The SPY-1 radar is one of 13 major...the AEGIS Weapon System could be adversely impacted if parts needed to maintain the SPY-1 radars are not transported to the warfighters when...for SPY-1 Radar Sustainment (Report No. DODIG-2016-116) We are providing this report for review and comment. Naval Supply Systems Command Weapon

  20. Analysing trends and forecasting malaria epidemics in Madagascar using a sentinel surveillance network: a web-based application.

    PubMed

    Girond, Florian; Randrianasolo, Laurence; Randriamampionona, Lea; Rakotomanana, Fanjasoa; Randrianarivelojosia, Milijaona; Ratsitorahina, Maherisoa; Brou, Télesphore Yao; Herbreteau, Vincent; Mangeas, Morgan; Zigiumugabe, Sixte; Hedje, Judith; Rogier, Christophe; Piola, Patrice

    2017-02-13

    The use of a malaria early warning system (MEWS) to trigger prompt public health interventions is a key step in adding value to the epidemiological data routinely collected by sentinel surveillance systems. This study describes a system using various epidemic thresholds and a forecasting component with the support of new technologies to improve the performance of a sentinel MEWS. Malaria-related data from 21 sentinel sites collected by Short Message Service are automatically analysed to detect malaria trends and malaria outbreak alerts with automated feedback reports. Roll Back Malaria partners can, through a user-friendly web-based tool, visualize potential outbreaks and generate a forecasting model. The system already demonstrated its ability to detect malaria outbreaks in Madagascar in 2014. This approach aims to maximize the usefulness of a sentinel surveillance system to predict and detect epidemics in limited-resource environments.

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hannum, David W.; Shannon, Gary W.

    This report describes the collaboration between the South Texas Specialized Crimes and Narcotics Task Force (STSCNTF) and Sandia National Laboratories (SNL) in a field test that provided prototype hand-held trace detection technology for use in counter-drug operations. The National Institute of Justice (NIJ)/National Law Enforcement and Corrections Technology Center (NLECTC)/Border Research and Technology Center (BRTC) was contacted by STSCNTF for assistance in obtaining cutting-edge technology. The BRTC created a pilot project for Sandia National Laboratories (SNL) and the STSCNTF for the use of SNL’s Hound, a hand-held sample collection and preconcentration system that, when combined with a commercial chemical detector,more » can be used for the trace detection of illicit drugs and explosives. The STSCNTF operates in an area of high narcotics trafficking where methods of concealment make the detection of narcotics challenging. Sandia National Laboratories’ (SNL) Contraband Detection Department personnel provided the Hound system hardware and operational training. The Hound system combines the GE VaporTracer2, a hand-held commercial chemical detector, with an SNL-developed sample collection and preconcentration system. The South Texas Task force reported a variety of successes, including identification of a major shipment of methamphetamines, the discovery of hidden compartments in vehicles that contained illegal drugs and currency used in drug deals, and the identification of a suspect in a nightclub shooting. The main advantage of the hand-held trace detection unit is its ability to quickly identify the type of chemical (drugs or explosives) without a long lag time for laboratory analysis, which is the most common analysis method for current law enforcement procedures.« less

  2. Prototype Systems Containing Human Cytochrome P450 for High-Throughput Real-Time Detection of DNA Damage by Compounds That Form DNA-Reactive Metabolites.

    PubMed

    Brito Palma, Bernardo; Fisher, Charles W; Rueff, José; Kranendonk, Michel

    2016-05-16

    The formation of reactive metabolites through biotransformation is the suspected cause of many adverse drug reactions. Testing for the propensity of a drug to form reactive metabolites has increasingly become an integral part of lead-optimization strategy in drug discovery. DNA reactivity is one undesirable facet of a drug or its metabolites and can lead to increased risk of cancer and reproductive toxicity. Many drugs are metabolized by cytochromes P450 in the liver and other tissues, and these reactions can generate hard electrophiles. These hard electrophilic reactive metabolites may react with DNA and may be detected in standard in vitro genotoxicity assays; however, the majority of these assays fall short due to the use of animal-derived organ extracts that inadequately represent human metabolism. The current study describes the development of bacterial systems that efficiently detect DNA-damaging electrophilic reactive metabolites generated by human P450 biotransformation. These assays use a GFP reporter system that detects DNA damage through induction of the SOS response and a GFP reporter to control for cytotoxicity. Two human CYP1A2-competent prototypes presented here have appropriate characteristics for the detection of DNA-damaging reactive metabolites in a high-throughput manner. The advantages of this approach include a short assay time (120-180 min) with real-time measurement, sensitivity to small amounts of compound, and adaptability to a microplate format. These systems are suitable for high-throughput assays and can serve as prototypes for the development of future enhanced versions.

  3. Signal averaging limitations in heterodyne- and direct-detection laser remote sensing measurements

    NASA Technical Reports Server (NTRS)

    Menyuk, N.; Killinger, D. K.; Menyuk, C. R.

    1983-01-01

    The improvement in measurement uncertainty brought about by the averaging of increasing numbers of pulse return signals in both heterodyne- and direct-detection lidar systems is investigated. A theoretical analysis is presented which shows the standard deviation of the mean measurement to decrease as the inverse square root of the number of measurements, except in the presence of temporal correlation. Experimental measurements based on a dual-hybrid-TEA CO2 laser differential absorption lidar system are reported which demonstrate that the actual reduction in the standard deviation of the mean in both heterodyne- and direct-detection systems is much slower than the inverse square-root dependence predicted for uncorrelated signals, but is in agreement with predictions in the event of temporal correlation. Results thus favor the use of direct detection at relatively short range where the lower limit of the standard deviation of the mean is about 2 percent, but advantages of heterodyne detection at longer ranges are noted.

  4. Biosensors and their applications in detection of organophosphorus pesticides in the environment.

    PubMed

    Hassani, Shokoufeh; Momtaz, Saeideh; Vakhshiteh, Faezeh; Maghsoudi, Armin Salek; Ganjali, Mohammad Reza; Norouzi, Parviz; Abdollahi, Mohammad

    2017-01-01

    This review discusses the past and recent advancements of biosensors focusing on detection of organophosphorus pesticides (OPs) due to their exceptional use during the last decades. Apart from agricultural benefits, OPs also impose adverse toxicological effects on animal and human population. Conventional approaches such as chromatographic techniques used for pesticide detection are associated with several limitations. A biosensor technology is unique due to the detection sensitivity, selectivity, remarkable performance capabilities, simplicity and on-site operation, fabrication and incorporation with nanomaterials. This study also provided specifications of the most OPs biosensors reported until today based on their transducer system. In addition, we highlighted the application of advanced complementary materials and analysis techniques in OPs detection systems. The availability of these new materials associated with new sensing techniques has led to introduction of easy-to-use analytical tools of high sensitivity and specificity in the design and construction of OPs biosensors. In this review, we elaborated the achievements in sensing systems concerning innovative nanomaterials and analytical techniques with emphasis on OPs.

  5. A reporter system for replication-competent gammaretroviruses: the inGluc-MLV-DERSE assay

    PubMed Central

    Aloia, Amanda L.; Duffy, Lisa; Pak, Vladimir; Lee, KyeongEun; Sanchez-Martinez, Silvia; Derse, David; Heidecker, Gisela; Cornetta, Kenneth; Rein, Alan

    2012-01-01

    While novel retroviral vectors for use in gene-therapy products are reducing the potential for formation of replication-competent retrovirus (RCR), it remains crucial to screen products for RCR for both research and clinical purposes. For clinical grade gammaretrovirus-based vectors, RCR screening is achieved by an extended S+L− or marker rescue assay, while standard methods for replication-competent lentivirus detection are still in development. In this report, we describe a rapid and sensitive method for replication-competent gammaretrovirus detection. We used this assay to detect three members of the gammaretrovirus family and compared the sensitivity of our assay with well-established methods for retrovirus detection, including the extended S+L− assay. Results presented here demonstrate that this assay should be useful for gene-therapy product testing. PMID:22402321

  6. Focused ultrasound: concept for automated transcutaneous control of hemorrhage in austere settings.

    PubMed

    Kucewicz, John C; Bailey, Michael R; Kaczkowski, Peter J; Carter, Stephen J

    2009-04-01

    High intensity focused ultrasound (HIFU) is being developed for a range of clinical applications. Of particular interest to NASA and the military is the use of HIFU for traumatic injuries because HIFU has the unique ability to transcutaneously stop bleeding. Automation of this technology would make possible its use in remote, austere settings by personnel not specialized in medical ultrasound. Here a system to automatically detect and target bleeding is tested and reported. The system uses Doppler ultrasound images from a clinical ultrasound scanner for bleeding detection and hardware for HIFU therapy. The system was tested using a moving string to simulate blood flow and targeting was visualized by Schlieren imaging to show the focusing of the HIFU acoustic waves. When instructed by the operator, a Doppler ultrasound image is acquired and processed to detect and localize the moving string, and the focus of the HIFU array is electronically adjusted to target the string. Precise and accurate targeting was verified in the Schlieren images. An automated system to detect and target simulated bleeding has been built and tested. The system could be combined with existing algorithms to detect, target, and treat clinical bleeding.

  7. Evanescent field Sensors Based on Tantalum Pentoxide Waveguides – A Review

    PubMed Central

    Schmitt, Katrin; Oehse, Kerstin; Sulz, Gerd; Hoffmann, Christian

    2008-01-01

    Evanescent field sensors based on waveguide surfaces play an important role where high sensitivity is required. Particularly tantalum pentoxide (Ta2O5) is a suitable material for thin-film waveguides due to its high refractive index and low attenuation. Many label-free biosensor systems such as grating couplers and interferometric sensors as well as fluorescence-based systems benefit from this waveguide material leading to extremely high sensitivity. Some biosensor systems based on Ta2O5 waveguides already took the step into commercialization. This report reviews the various detection systems in terms of limit of detection, the applications, and the suitable surface chemistry. PMID:27879731

  8. Tunable sensitivity phase detection of transmitted-type dual-channel guided-mode resonance sensor based on phase-shift interferometry.

    PubMed

    Kuo, Wen-Kai; Syu, Siang-He; Lin, Peng-Zhi; Yu, Hsin Her

    2016-02-01

    This paper reports on a transmitted-type dual-channel guided-mode resonance (GMR) sensor system that uses phase-shifting interferometry (PSI) to achieve tunable phase detection sensitivity. Five interference images are captured for the PSI phase calculation within ∼15  s by using a liquid crystal retarder and a USB web camera. The GMR sensor structure is formed by a nanoimprinting process, and the dual-channel sensor device structure for molding is fabricated using a 3D printer. By changing the rotation angle of the analyzer in front of the camera in the PSI system, the sensor detection sensitivity can be tuned. The proposed system may achieve high throughput as well as high sensitivity. The experimental results show that an optimal detection sensitivity of 6.82×10(-4)  RIU can be achieved.

  9. Defense Departmental Reporting System-Budgetary Was Not Effectively Implemented for the Army General Fund

    DTIC Science & Technology

    2012-05-31

    or events. Unsupported journal vouchers increase the risk of materially misstated balances reported on the AGF financial statements. DFAS...with U.S. generally accepted accounting principles and that the Army automated systems did not support material amounts on the financial statements...files, abnormal balance detection , journal vouchers, and reconciliations between Army and OMB SF 133s and the Statements of Budgetary Resources

  10. Emergence of new norovirus variants on spring cruise ships and prediction of winter epidemics.

    PubMed

    Verhoef, Linda; Depoortere, Evelyn; Boxman, Ingeborg; Duizer, Erwin; van Duynhoven, Yvonne; Harris, John; Johnsen, Christina; Kroneman, Annelies; Le Guyader, Soizick; Lim, Wilina; Maunula, Leena; Meldal, Hege; Ratcliff, Rod; Reuter, Gábor; Schreier, Eckart; Siebenga, Joukje; Vainio, Kirsti; Varela, Carmen; Vennema, Harry; Koopmans, Marion

    2008-02-01

    In June 2006, reported outbreaks of norovirus on cruise ships suddenly increased; 43 outbreaks occurred on 13 vessels. All outbreaks investigated manifested person-to-person transmission. Detection of a point source was impossible because of limited investigation of initial outbreaks and data sharing. The most probable explanation for these outbreaks is increased norovirus activity in the community, which coincided with the emergence of 2 new GGII.4 variant strains in Europe and the Pacific. As in 2002, a new GGII.4 variant detected in the spring and summer corresponded with high norovirus activity in the subsequent winter. Because outbreaks on cruise ships are likely to occur when new variants circulate, an active reporting system could function as an early warning system. Internationally accepted guidelines are needed for reporting, investigating, and controlling norovirus illness on cruise ships in Europe.

  11. Emergence of New Norovirus Variants on Spring Cruise Ships and Prediction of Winter Epidemics

    PubMed Central

    Depoortere, Evelyn; Boxman, Ingeborg; Duizer, Erwin; van Duynhoven, Yvonne; Harris, John; Johnsen, Christina; Kroneman, Annelies; Le Guyader, Soizick; Lim, Wilina; Maunula, Leena; Meldal, Hege; Ratcliff, Rod; Reuter, Gábor; Schreier, Eckart; Siebenga, Joukje; Vainio, Kirsti; Varela, Carmen; Vennema, Harry; Koopmans, Marion

    2008-01-01

    In June 2006, reported outbreaks of norovirus on cruise ships suddenly increased; 43 outbreaks occurred on 13 vessels. All outbreaks investigated manifested person-to-person transmission. Detection of a point source was impossible because of limited investigation of initial outbreaks and data sharing. The most probable explanation for these outbreaks is increased norovirus activity in the community, which coincided with the emergence of 2 new GGII.4 variant strains in Europe and the Pacific. As in 2002, a new GGII.4 variant detected in the spring and summer corresponded with high norovirus activity in the subsequent winter. Because outbreaks on cruise ships are likely to occur when new variants circulate, an active reporting system could function as an early warning system. Internationally accepted guidelines are needed for reporting, investigating, and controlling norovirus illness on cruise ships in Europe. PMID:18258116

  12. Fermi GBM Observations During the Second Observing Run of LIGO/Virgo

    NASA Astrophysics Data System (ADS)

    Goldstein, Adam; Fermi-GBM

    2018-01-01

    The Fermi Gamma-ray Burst Monitor (GBM) is a prolific detector of gamma-ray bursts (GRBs) and detects more short duration GRBs than any other instrument currently in operation. Short GRBs are thought to be associated with the mergers of binary neutron star systems (or neutron star-black hole systems), and are therefore considered likely counterparts to gravitational-wave detections from LIGO/Virgo. We report on the GBM observations during the second observing run of LIGO/Virgo and detail the physical and astrophysical insights that might be gleaned from a joint detection of a short GRB and a gravitational-wave source.

  13. Object acquisition and tracking for space-based surveillance. Final report, Dec 88-May 90

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1991-11-27

    This report presents the results of research carried out by Space Computer Corporation under the U.S. government's Small Business Innovation Research (SBIR) Program. The work was sponsored by the Strategic Defense Initiative Organization and managed by the Office of Naval Research under Contracts N00014-87-C-0801 (Phase I) and N00014-89-C-0015 (Phase II). The basic purpose of this research was to develop and demonstrate a new approach to the detection of, and initiation of track on, moving targets using data from a passive infrared or visual sensor. This approach differs in very significant ways from the traditional approach of dividing the required processingmore » into time dependent, object-dependent, and data-dependent processing stages. In that approach individual targets are first detected in individual image frames, and the detections are then assembled into tracks. That requires that the signal to noise ratio in each image frame be sufficient for fairly reliable target detection. In contrast, our approach bases detection of targets on multiple image frames, and, accordingly, requires a smaller signal to noise ratio. It is sometimes referred to as track before detect, and can lead to a significant reduction in total system cost. For example, it can allow greater detection range for a single sensor, or it can allow the use of smaller sensor optics. Both the traditional and track before detect approaches are applicable to systems using scanning sensors, as well as those which use staring sensors.« less

  14. Swift observations of SDSS J141118.31+481257.6 during its first detected outburst

    NASA Astrophysics Data System (ADS)

    Sandoval, L. E. Rivera; Maccarone, T.

    2018-05-01

    We report Swift observations of the AM CVn-type system SDSS J141118.31+481257.6 (RA=14:11:18.31, Dec=+48:12:57.6) during its first ever recorded outburst. The system was detected by Tadashi Kojima on 2018-May-20 with a V magnitude of 12.6 +- 0.2 (http://ooruri.kusastro.kyoto-u.ac.jp/mailarchive/vsnet-alert/22176), an increase of 7 mags compared to any previous measurement in the same filter.

  15. Reporter gene bioassays in environmental analysis.

    PubMed

    Köhler, S; Belkin, S; Schmid, R D

    2000-01-01

    In parallel to the continuous development of increasingly more sophisticated physical and chemical analytical technologies for the detection of environmental pollutants, there is a progressively more urgent need also for bioassays which report not only on the presence of a chemical but also on its bioavailability and its biological effects. As a partial fulfillment of that need, there has been a rapid development of biosensors based on genetically engineered bacteria. Such microorganisms typically combine a promoter-operator, which acts as the sensing element, with reporter gene(s) coding for easily detectable proteins. These sensors have the ability to detect global parameters such as stress conditions, toxicity or DNA-damaging agents as well as specific organic and inorganic compounds. The systems described in this review, designed to detect different groups of target chemicals, vary greatly in their detection limits, specificity, response times and more. These variations reflect on their potential applicability which, for most of the constructs described, is presently rather limited. Nevertheless, present trends promise that additional improvements will make microbial biosensors an important tool for future environmental analysis.

  16. Direct Detection of Hardly Detectable Hidden Chirality of Hydrocarbons and Deuterated Isotopomers by a Helical Polyacetylene through Chiral Amplification and Memory.

    PubMed

    Maeda, Katsuhiro; Hirose, Daisuke; Okoshi, Natsuki; Shimomura, Kouhei; Wada, Yuya; Ikai, Tomoyuki; Kanoh, Shigeyoshi; Yashima, Eiji

    2018-03-07

    We report the first direct chirality sensing of a series of chiral hydrocarbons and isotopically chiral compounds (deuterated isotopomers), which are almost impossible to detect by conventional optical spectroscopic methods, by a stereoregular polyacetylene bearing 2,2'-biphenol-derived pendants. The polyacetylene showed a circular dichroism due to a preferred-handed helix formation in response to the hardly detectable hidden chirality of saturated tertiary or chiroptical quaternary hydrocarbons, and deuterated isotopomers. In sharp contrast to the previously reported sensory systems, the chirality detection by the polyacetylene relies on an excess one-handed helix formation induced by the chiral hydrocarbons and deuterated isotopomers via significant amplification of the chirality followed by its static memory, through which chiral information on the minute and hidden chirality can be stored as an excess of a single-handed helix memory for a long time.

  17. Bio-Photonic Detection of Various Cellular Cultures

    NASA Astrophysics Data System (ADS)

    Hann, Patrick; Garzon, Maria; Pfeiffer, Erik; Lofland, Samuel; Knoesel, Ernst

    2008-03-01

    Since it is non-invasive, there has been increased research in the field of bio-optics. Many biological systems display an unusual phenomenon, delayed luminescence, produced by what is known as bio-photons. We present an apparatus and procedure for the detection of these ultra-weak photonic emissions using a single photon detection device. The results of bread yeast, saccramyces, and algae will be presented and compared to other reports in the literature

  18. Test and evaluation of the Airport Surveillance Radar (ASR)-8 wind shear detection system (phase 2), revision

    NASA Astrophysics Data System (ADS)

    Offi, D. L.; Lewis, W.; Lee, T.; Delamarche, A.

    1980-08-01

    A wind shear detection system developed by the Wave Propagation Laboratory (WPL) to operate with the Federal Aviation Administration (FAA) Airport Surveillance Radar (ASR)-8 was installed and is being tested at the FAA technical Center. Initial efforts, previously reported in Report NA-78-59-LR, were directed toward hardware and software shakedown and feasibility determination. Second phase tests compared radar with aircraft and tower winds, evaluated the wind shear measurement capability under various weather conditions, and investigated the effectiveness of a simple two-azimuth pointing strategy and system capabilities and limitations. Results showed the system to be compatible with and to operate satisfactorily with the ASR-8. The processing and spectral display of clear air and precipitation returns is feasible. The accuracy of agreement between radar-measured winds and components of the aircraft-measured winds in both radially oriented flights and runway offset flights, using a two-azimuth pointing technique, was examined. Radar versus tower wind agreement was also examined. Potentially dangerous wind shears associated with weather during these tests were detectable. Certain system limitations also have been defined and considered. It is recommended that tests continue to complete definition of and demonstrate capabilities in all weather situations, to optimize performance, and to provide information to specify system design for possible development of a prototype model.

  19. The attributes of medical event-reporting systems: experience with a prototype medical event-reporting system for transfusion medicine.

    PubMed

    Battles, J B; Kaplan, H S; Van der Schaaf, T W; Shea, C E

    1998-03-01

    To design, develop, and implement a prototype medical event-reporting system for use in transfusion medicine to improve transfusion safety by studying incidents and errors. The IDEALS concept of design was used to identify specifications for the event-reporting system, and a Delphi and subsequent nominal group technique meetings were used to reach consensus on the development of the system. An interdisciplinary panel of experts from aviation safety, nuclear power, cognitive psychology, artificial intelligence, and education and representatives of major transfusion medicine organizations participated in the development process. Setting.- Three blood centers and three hospital transfusion services implemented the reporting system. A working prototype event-reporting system was recommended and implemented. The system has seven components: detection, selection, description, classification, computation, interpretation, and local evaluation. Its unique features include no-fault reporting initiated by the individual discovering the event, who submits a report that is investigated by local quality assurance personnel and forwarded to a nonregulatory central system for computation and interpretation. An event-reporting system incorporated into present quality assurance and risk management efforts can help organizations address system structural and procedural weakness where the potential for errors can adversely affect health care outcomes. Input from the end users of the system as well as from external experts should enable this reporting system to serve as a useful model for others who may develop event-reporting systems in other medical domains.

  20. Holographic particle detection

    NASA Technical Reports Server (NTRS)

    Bowen, Theodore

    1988-01-01

    The feasibility was studied of developing a novel particle track detector based on the detection of 1p-1s emission radiation from electron bubbles in liquid helium. The principles, design, construction, and initial testing of the detection system have been described in previous reports. The main obstacle encountered was the construction of the liquid-helium tight infrared windows. Despite numerous efforts in testing and redesigning the windows, the problem of window leakage at low temperature persisted. Due to limited time and resources, attention was switched to investigating the possibility of using room-temperature liquid as the detection medium. A possible mechanism was the detection of de-excitation radiation emitted from localized electrons in common liquids where electrons exhibit low mobilities, as suggested in the previous report. The purity of the liquid is critical in this method as the dissolved impurities (such as oxygen), even in trace amounts, will act as scavengers of electrons. Another mechanism is discussed whereby the formation of the superoxide ions by electron scavenging behavior of dissolved oxygen is exploited to detect the track of ionizing particles. An experiment to measure the ionization current produced in a liquid by a pulsed X-ray beam in order to study propertiies of the ions is also reported.

  1. GPS aviation outage prediction and reporting systems

    DOT National Transportation Integrated Search

    1997-11-01

    Use of GPS for instrument flight rule (IFR) air navigation requires that the system have integrity. Integrity is the ability to detect when a satellite is out of tolerance and should not be used in the navigation solution and then warns the pilot in ...

  2. Utility of social media and crowd-intelligence data for pharmacovigilance: a scoping review.

    PubMed

    Tricco, Andrea C; Zarin, Wasifa; Lillie, Erin; Jeblee, Serena; Warren, Rachel; Khan, Paul A; Robson, Reid; Pham, Ba'; Hirst, Graeme; Straus, Sharon E

    2018-06-14

    A scoping review to characterize the literature on the use of conversations in social media as a potential source of data for detecting adverse events (AEs) related to health products. Our specific research questions were (1) What social media listening platforms exist to detect adverse events related to health products, and what are their capabilities and characteristics? (2) What is the validity and reliability of data from social media for detecting these adverse events? MEDLINE, EMBASE, Cochrane Library, and relevant websites were searched from inception to May 2016. Any type of document (e.g., manuscripts, reports) that described the use of social media data for detecting health product AEs was included. Two reviewers independently screened citations and full-texts, and one reviewer and one verifier performed data abstraction. Descriptive synthesis was conducted. After screening 3631 citations and 321 full-texts, 70 unique documents with 7 companion reports available from 2001 to 2016 were included. Forty-six documents (66%) described an automated or semi-automated information extraction system to detect health product AEs from social media conversations (in the developmental phase). Seven pre-existing information extraction systems to mine social media data were identified in eight documents. Nineteen documents compared AEs reported in social media data with validated data and found consistent AE discovery in all except two documents. None of the documents reported the validity and reliability of the overall system, but some reported on the performance of individual steps in processing the data. The validity and reliability results were found for the following steps in the data processing pipeline: data de-identification (n = 1), concept identification (n = 3), concept normalization (n = 2), and relation extraction (n = 8). The methods varied widely, and some approaches yielded better results than others. Our results suggest that the use of social media conversations for pharmacovigilance is in its infancy. Although social media data has the potential to supplement data from regulatory agency databases; is able to capture less frequently reported AEs; and can identify AEs earlier than official alerts or regulatory changes, the utility and validity of the data source remains under-studied. Open Science Framework ( https://osf.io/kv9hu/ ).

  3. Meteorological and Environmental Inputs to Aviation Systems

    NASA Technical Reports Server (NTRS)

    Camp, Dennis W. (Editor); Frost, Walter (Editor)

    1988-01-01

    Reports on aviation meteorology, most of them informal, are presented by representatives of the National Weather Service, the Bracknell (England) Meteorological Office, the NOAA Wave Propagation Lab., the Fleet Numerical Oceanography Center, and the Aircraft Owners and Pilots Association. Additional presentations are included on aircraft/lidar turbulence comparison, lightning detection and locating systems, objective detection and forecasting of clear air turbulence, comparative verification between the Generalized Exponential Markov (GEM) Model and official aviation terminal forecasts, the evaluation of the Prototype Regional Observation and Forecast System (PROFS) mesoscale weather products, and the FAA/MIT Lincoln Lab. Doppler Weather Radar Program.

  4. Shallow Water Imaging Sonar System for Environmental Surveying Final Report CRADA No. TC-1130-95

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ng, L. C.; Rosenbaum, H.

    The scope of this research is to develop a shallow water sonar system designed to detect and map the location of objects such as hazardous wastes or discarded ordnance in coastal waters. The system will use high frequency wide-bandwidth imaging sonar, mounted on a moving platform towed behind a boat, to detect and identify objects on the sea bottom. Resolved images can be obtained even if the targets are buried in an overlayer of silt. Reference 1 ( also attached) summarized the statement of work and the scope of collaboration.

  5. Automated clinical system for chromosome analysis

    NASA Technical Reports Server (NTRS)

    Castleman, K. R.; Friedan, H. J.; Johnson, E. T.; Rennie, P. A.; Wall, R. J. (Inventor)

    1978-01-01

    An automatic chromosome analysis system is provided wherein a suitably prepared slide with chromosome spreads thereon is placed on the stage of an automated microscope. The automated microscope stage is computer operated to move the slide to enable detection of chromosome spreads on the slide. The X and Y location of each chromosome spread that is detected is stored. The computer measures the chromosomes in a spread, classifies them by group or by type and also prepares a digital karyotype image. The computer system can also prepare a patient report summarizing the result of the analysis and listing suspected abnormalities.

  6. Highly sensitive and selective microRNA detection based on DNA-bio-bar-code and enzyme-assisted strand cycle exponential signal amplification.

    PubMed

    Dong, Haifeng; Meng, Xiangdan; Dai, Wenhao; Cao, Yu; Lu, Huiting; Zhou, Shufeng; Zhang, Xueji

    2015-04-21

    Herein, a highly sensitive and selective microRNA (miRNA) detection strategy using DNA-bio-bar-code amplification (BCA) and Nb·BbvCI nicking enzyme-assisted strand cycle for exponential signal amplification was designed. The DNA-BCA system contains a locked nucleic acid (LNA) modified DNA probe for improving hybridization efficiency, while a signal reported molecular beacon (MB) with an endonuclease recognition site was designed for strand cycle amplification. In the presence of target miRNA, the oligonucleotides functionalized magnetic nanoprobe (MNP-DNA) and gold nanoprobe (AuNP-DNA) with numerous reported probes (RP) can hybridize with target miRNA, respectively, to form a sandwich structure. After sandwich structures were separated from the solution by the magnetic field, the RP were released under high temperature to recognize the MB and cleaved the hairpin DNA to induce the dissociation of RP. The dissociated RP then triggered the next strand cycle to produce exponential fluorescent signal amplification for miRNA detection. Under optimized conditions, the exponential signal amplification system shows a good linear range of 6 orders of magnitude (from 0.3 pM to 3 aM) with limit of detection (LOD) down to 52.5 zM, while the sandwich structure renders the system with high selectivity. Meanwhile, the feasibility of the proposed strategy for cell miRNA detection was confirmed by analyzing miRNA-21 in HeLa lysates. Given the high-performance for miRNA analysis, the strategy has a promising application in biological detection and in clinical diagnosis.

  7. Simulation of a Doppler lidar system for autonomous navigation and hazard avoidance during planetary landing

    NASA Astrophysics Data System (ADS)

    Budge, Scott E.; Chester, David B.

    2016-05-01

    The latest mission proposals for exploration of solar system bodies require accurate position and velocity data during the descent phase in order to ensure safe, soft landing at the pre-designated sites. During landing maneuvers, the accuracy of the on-board inertial measurement unit (IMU) may not be reliable due to drift over extended travel times to destinations. NASA has proposed an advanced Doppler lidar system with multiple beams that can be used to accurately determine attitude and position of the landing vehicle during descent, and to detect hazards that might exist in the landing area. In order to assess the effectiveness of such a Doppler lidar landing system, it is valuable to simulate the system with different beam numbers and configurations. In addition, the effectiveness of the system to detect and map potential landing hazards must be understood. This paper reports the simulated system performance for a proposed multi-beam Doppler lidar using the LadarSIM system simulation software. Details of the simulation methods are given, as well as lidar performance parameters such as range and velocity accuracy, detection and false alarm rates, and examples of the Doppler lidars ability to detect and characterize simulated hazards in the landing site. The simulation includes modulated pulse generation and coherent detection methods, beam footprint simulation, beam scanning, and interaction with terrain.

  8. Voice Interactive Analysis System Study. Final Report, August 28, 1978 through March 23, 1979.

    ERIC Educational Resources Information Center

    Harry, D. P.; And Others

    The Voice Interactive Analysis System study continued research and development of the LISTEN real-time, minicomputer based connected speech recognition system, within NAVTRAEQUIPCEN'S program of developing automatic speech technology in support of training. An attempt was made to identify the most effective features detected by the TTI-500 model…

  9. Non-iterative Voltage Stability

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Makarov, Yuri V.; Vyakaranam, Bharat; Hou, Zhangshuan

    2014-09-30

    This report demonstrates promising capabilities and performance characteristics of the proposed method using several power systems models. The new method will help to develop a new generation of highly efficient tools suitable for real-time parallel implementation. The ultimate benefit obtained will be early detection of system instability and prevention of system blackouts in real time.

  10. Rule-Based Relaxation of Reference Identification Failures. Technical Report No. 396.

    ERIC Educational Resources Information Center

    Goodman, Bradley A.

    In a step toward creating a robust natural language understanding system which detects and avoids miscommunication, this artificial intelligence research report provides a taxonomy of miscommunication problems that arise in expert-apprentice dialogues (including misunderstandings, wrong communication, and bad analogies), and proposes a flexible…

  11. Development and Measurements of a Mid-Infrared Multi-Gas Sensor System for CO, CO2 and CH4 Detection

    PubMed Central

    Dong, Ming; Zheng, Chuantao; Miao, Shuzhuo; Zhang, Yu; Du, Qiaoling; Wang, Yiding

    2017-01-01

    A multi-gas sensor system was developed that uses a single broadband light source and multiple carbon monoxide (CO), carbon dioxide (CO2) and methane (CH4) pyroelectric detectors by use of the time division multiplexing (TDM) technique. A stepper motor-based rotating system and a single-reflection spherical optical mirror were designed and adopted to realize and enhance multi-gas detection. Detailed measurements under static detection mode (without rotation) and dynamic mode (with rotation) were performed to study the performance of the sensor system for the three gas species. Effects of the motor rotating period on sensor performances were also investigated and a rotation speed of 0.4π rad/s was required to obtain a stable sensing performance, corresponding to a detection period of ~10 s to realize one round of detection. Based on an Allan deviation analysis, the 1σ detection limits under static operation are 2.96, 4.54 and 2.84 parts per million in volume (ppmv) for CO, CO2 and CH4, respectively and the 1σ detection limits under dynamic operations are 8.83, 8.69 and 10.29 ppmv for the three gas species, respectively. The reported sensor has potential applications in various fields requiring CO, CO2 and CH4 detection such as in coal mines. PMID:28953260

  12. Sorting Out Antibiotics' Mechanisms of Action: a Double Fluorescent Protein Reporter for High-Throughput Screening of Ribosome and DNA Biosynthesis Inhibitors

    PubMed Central

    Osterman, Ilya A.; Komarova, Ekaterina S.; Shiryaev, Dmitry I.; Korniltsev, Ilya A.; Khven, Irina M.; Lukyanov, Dmitry A.; Tashlitsky, Vadim N.; Serebryakova, Marina V.; Efremenkova, Olga V.; Ivanenkov, Yan A.; Bogdanov, Alexey A.; Dontsova, Olga A.

    2016-01-01

    In order to accelerate drug discovery, a simple, reliable, and cost-effective system for high-throughput identification of a potential antibiotic mechanism of action is required. To facilitate such screening of new antibiotics, we created a double-reporter system for not only antimicrobial activity detection but also simultaneous sorting of potential antimicrobials into those that cause ribosome stalling and those that induce the SOS response due to DNA damage. In this reporter system, the red fluorescent protein gene rfp was placed under the control of the SOS-inducible sulA promoter. The gene of the far-red fluorescent protein, katushka2S, was inserted downstream of the tryptophan attenuator in which two tryptophan codons were replaced by alanine codons, with simultaneous replacement of the complementary part of the attenuator to preserve the ability to form secondary structures that influence transcription termination. This genetically modified attenuator makes possible Katushka2S expression only upon exposure to ribosome-stalling compounds. The application of red and far-red fluorescent proteins provides a high signal-to-background ratio without any need of enzymatic substrates for detection of the reporter activity. This reporter was shown to be efficient in high-throughput screening of both synthetic and natural chemicals. PMID:27736765

  13. Detecting NEO Impacts using the International Monitoring System

    NASA Astrophysics Data System (ADS)

    Brown, Peter G.; Dube, Kimberlee; Silber, Elizabeth

    2014-11-01

    As part of the verification regime for the Comprehensive Nuclear Test Ban Treaty an International Monitoring System (IMS) consisting of seismic, hydroacoustic, infrasound and radionuclide technologies has been globally deployed beginning in the late 1990s. The infrasound network sub-component of the IMS consists of 47 active stations as of mid-2014. These microbarograph arrays detect coherent infrasonic signals from a range of sources including volcanoes, man-made explosions and bolides. Bolide detections from IMS stations have been reported since ~2000, but with the maturation of the network over the last several years the rate of detections has increased substantially. Presently the IMS performs semi-automated near real-time global event identification on timescales of 6-12 hours as well as analyst verified event identification having time lags of several weeks. Here we report on infrasound events identified by the IMS between 2010-2014 which are likely bolide impacts. Identification in this context refers to an event being included in one of the event bulletins issued by the IMS. In this untargeted study we find that the IMS globally identifies approximately 16 events per year which are likely bolide impacts. Using data released since the beginning of 2014 of US Government sensor detections (as given at http://neo.jpl.nasa.gov/fireballs/ ) of fireballs we find in a complementary targeted survey that the current IMS system is able to identify ~25% of fireballs with E > 0.1 kT energy. Using all 16 US Government sensor fireballs listed as of July 31, 2014 we are able to detect infrasound from 75% of these events on at least one IMS station. The high ratio of detection/identification is a product of the stricter criteria adopted by the IMS for inclusion in an event bulletin as compared to simple station detection.We discuss energy comparisons between infrasound-estimated energies based on amplitudes and periods and estimates provided by US Government sensors. Specific impact events of interest will be discussed as well as the utility of the global IMS infrasound system for location and timing of future NEAs detected prior to impact.

  14. Analysis and design of a capsule landing system and surface vehicle control system for Mars exploration

    NASA Technical Reports Server (NTRS)

    Frederick, D. K.; Lashmet, P. K.; Sandor, G. N.; Shen, C. N.; Smith, E. V.; Yerazunis, S. W.

    1973-01-01

    Problems related to the design and control of a mobile planetary vehicle to implement a systematic plan for the exploration of Mars are reported. Problem areas include: vehicle configuration, control, dynamics, systems and propulsion; systems analysis, terrain modeling and path selection; and chemical analysis of specimens. These tasks are summarized: vehicle model design, mathematical model of vehicle dynamics, experimental vehicle dynamics, obstacle negotiation, electrochemical controls, remote control, collapsibility and deployment, construction of a wheel tester, wheel analysis, payload design, system design optimization, effect of design assumptions, accessory optimal design, on-board computer subsystem, laser range measurement, discrete obstacle detection, obstacle detection systems, terrain modeling, path selection system simulation and evaluation, gas chromatograph/mass spectrometer system concepts, and chromatograph model evaluation and improvement.

  15. Decision support environment for medical product safety surveillance.

    PubMed

    Botsis, Taxiarchis; Jankosky, Christopher; Arya, Deepa; Kreimeyer, Kory; Foster, Matthew; Pandey, Abhishek; Wang, Wei; Zhang, Guangfan; Forshee, Richard; Goud, Ravi; Menschik, David; Walderhaug, Mark; Woo, Emily Jane; Scott, John

    2016-12-01

    We have developed a Decision Support Environment (DSE) for medical experts at the US Food and Drug Administration (FDA). The DSE contains two integrated systems: The Event-based Text-mining of Health Electronic Records (ETHER) and the Pattern-based and Advanced Network Analyzer for Clinical Evaluation and Assessment (PANACEA). These systems assist medical experts in reviewing reports submitted to the Vaccine Adverse Event Reporting System (VAERS) and the FDA Adverse Event Reporting System (FAERS). In this manuscript, we describe the DSE architecture and key functionalities, and examine its potential contributions to the signal management process by focusing on four use cases: the identification of missing cases from a case series, the identification of duplicate case reports, retrieving cases for a case series analysis, and community detection for signal identification and characterization. Published by Elsevier Inc.

  16. Visualization of ecdysteroid activity using a reporter gene in the crustacean, Daphnia.

    PubMed

    Asada, Miki; Kato, Yasuhiko; Matsuura, Tomoaki; Watanabe, Hajime

    2014-02-01

    Ecdysone is a hormone known to play a pivotal role in crustaceans and insects. In order to evaluate the ecdysone activities in the environment and within the organism, we have developed a biomonitoring Daphnia strain by introducing a reporter gene. In this study, the ecdysone response element was inserted in the upstream region of a reporter gene, and the DNA construct was injected into Daphnia eggs. The expression of the reporter gene was detected during the early embryonic development stage. In addition, when the eggs expressing the reporter gene were exposed to ecdysone, there was enhanced expression of the reporter gene at detectable levels, while the presence of an antagonist led to its downregulation. These results suggested that this system could be potentially developed for monitoring ecdysone activities in media. Copyright © 2013 Elsevier Ltd. All rights reserved.

  17. A miniaturized 4 K platform for superconducting infrared photon counting detectors

    NASA Astrophysics Data System (ADS)

    Gemmell, Nathan R.; Hills, Matthew; Bradshaw, Tom; Rawlings, Tom; Green, Ben; Heath, Robert M.; Tsimvrakidis, Konstantinos; Dobrovolskiy, Sergiy; Zwiller, Val; Dorenbos, Sander N.; Crook, Martin; Hadfield, Robert H.

    2017-11-01

    We report on a miniaturized platform for superconducting infrared photon counting detectors. We have implemented a fibre-coupled superconducting nanowire single photon detector in a Stirling/Joule-Thomson platform with a base temperature of 4.2 K. We have verified a cooling power of 4 mW at 4.7 K. We report 20% system detection efficiency at 1310 nm wavelength at a dark count rate of 1 kHz. We have carried out compelling application demonstrations in single photon depth metrology and singlet oxygen luminescence detection.

  18. Hand-held microwave search detector

    NASA Astrophysics Data System (ADS)

    Daniels, David J.; Philippakis, Mike

    2005-05-01

    This paper describes the further development of a patented, novel, low cost, microwave search detector using noise radar technology operating in the 27-40GHz range of frequencies, initially reported in SPIE 2004. Initial experiments have shown that plastic explosives, ceramics and plastic material hidden on the body can be detected with the system. This paper considers the basic physics of the technique and reports on the development of a initial prototype system for hand search of suspects and addresses the work carried out on optimisation of PD and FAR. The radar uses a novel lens system and the design and modelling of this for optimum depth of field of focus will be reported.

  19. TEMTADS Adjunct Sensor Systems Hand-held EMI Sensor for Cued UXO Discrimination (ESTCP MR-200807) and Man-Portable EMI Array for UXO Detection and Discrimination (ESTCP MR-200909) Cost and Performance Report

    DTIC Science & Technology

    2012-06-27

    notes and team orienteering functions. Data collection with the MP system at the former Camp Beale, CA is shown in Figure 5- 2 (right). 5.3.3...Naval Research Laboratory Washington, DC 20375-5320 NRL/MR/ 6110 --12-9424 TEMTADS Adjunct Sensor Systems Hand-held EMI Sensor for Cued UXO...CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 5d. PROJECT NUMBER 5e. TASK NUMBER 5f. WORK UNIT NUMBER 2 . REPORT TYPE1. REPORT DATE (DD

  20. [Intelligent videosurveillance and falls detection: Perceptions of professionals and managers].

    PubMed

    Lapierre, Nolwenn; Carpentier, Isabelle; St-Arnaud, Alain; Ducharme, Francine; Meunier, Jean; Jobidon, Mireille; Rousseau, Jacqueline

    2016-02-01

    Gerontechnologies can be used to detect accidental falls. However, existing systems do not entirely meet users' expectations. Our team developed an intelligent video-monitoring systems to fill these gaps. Authors advocate consulting potential users at the early stages of the design of gerontechnologies and integrating their suggestions. This study aims to explore health care workers' opinion regarding the intelligent video monitoring to detect falls by older adults living at home. This qualitative study explored the opinions of 31 participants using focus groups. Transcripts were analyzed using predetermined codes based on the competence model. Participants reported several advantages for using the intelligent video monitoring and provided suggestions for improving its use. The participants' suggestions and comments will help to improve the system and match it to users' needs. © CAOT 2015.

  1. The detection of organophosphonates by polymer films on a surface acoustic wave device and a micromirror fiber optic sensor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hughes, R.C.; Ricco, A.J.; Butler, M.A.

    There is a need for sensitive detection of organophosphonates by, inexpensive, portable instruments. Two kinds of chemical sensors, based on surface acoustic wave (SAW) devices and fiber optic micromirrors, show promise for such sensing systems. Chemically sensitive coatings are required for detection and data for thin films of the polymer polysiloxane are reported for both kinds of physical transducers. Both kinds of sensor are shown to be capable of detecting concentrations of diisopropylmethylphosphonate (DIMP) down to 1 ppM.

  2. A survey of atmospheric monitoring systems in U.S. underground coal mines

    PubMed Central

    Rowland, J.H.; Harteis, S.P.; Yuan, L.

    2018-01-01

    In 1995 and 2003, the U.S. Mine Safety and Health Administration (MSHA) conducted surveys to determine the number of atmospheric monitoring systems (AMS) that were being used in underground coal mines in the United States. The survey reports gave data for the different AMS manufacturers, the different types of equipment monitored, and the different types of gas sensors and their locations. Since the last survey in 2003, MSHA has changed the regulation requirements for early fire detection along belt haulage entries. As of Dec. 31, 2009, point-type heat sensors are prohibited for use for an early fire detection system. Instead, carbon monoxide (CO) sensors are now required. This report presents results from a new survey and examines how the regulation changes have had an impact on the use of CO sensors in underground coal mines in the United States. The locations and parameters monitored by AMS and CO systems are also discussed. PMID:29674789

  3. Avoiding Pandemic Fears in the Subway and Conquering the Platypus.

    PubMed

    Gonzalez, A; Vázquez-Baeza, Y; Pettengill, J B; Ottesen, A; McDonald, D; Knight, R

    2016-01-01

    Metagenomics is increasingly used not just to show patterns of microbial diversity but also as a culture-independent method to detect individual organisms of intense clinical, epidemiological, conservation, forensic, or regulatory interest. A widely reported metagenomic study of the New York subway suggested that the pathogens Yersinia pestis and Bacillus anthracis were part of the "normal subway microbiome." In their article in mSystems, Hsu and collaborators (mSystems 1(3):e00018-16, 2016, http://dx.doi.org/10.1128/mSystems.00018-16) showed that microbial communities on transit surfaces in the Boston subway system are maintained from a metapopulation of human skin commensals and environmental generalists and that reanalysis of the New York subway data with appropriate methods did not detect the pathogens. We note that commonly used software pipelines can produce results that lack prima facie validity (e.g., reporting widespread distribution of notorious endemic species such as the platypus or the presence of pathogens) but that appropriate use of inclusion and exclusion sets can avoid this issue.

  4. Applications for detection of acute kidney injury using electronic medical records and clinical information systems: workgroup statements from the 15(th) ADQI Consensus Conference.

    PubMed

    James, Matthew T; Hobson, Charles E; Darmon, Michael; Mohan, Sumit; Hudson, Darren; Goldstein, Stuart L; Ronco, Claudio; Kellum, John A; Bagshaw, Sean M

    2016-01-01

    Electronic medical records and clinical information systems are increasingly used in hospitals and can be leveraged to improve recognition and care for acute kidney injury. This Acute Dialysis Quality Initiative (ADQI) workgroup was convened to develop consensus around principles for the design of automated AKI detection systems to produce real-time AKI alerts using electronic systems. AKI alerts were recognized by the workgroup as an opportunity to prompt earlier clinical evaluation, further testing and ultimately intervention, rather than as a diagnostic label. Workgroup members agreed with designing AKI alert systems to align with the existing KDIGO classification system, but recommended future work to further refine the appropriateness of AKI alerts and to link these alerts to actionable recommendations for AKI care. The consensus statements developed in this review can be used as a roadmap for development of future electronic applications for automated detection and reporting of AKI.

  5. A Control Allocation System for Automatic Detection and Compensation of Phase Shift Due to Actuator Rate Limiting

    NASA Technical Reports Server (NTRS)

    Yildiz, Yidiray; Kolmanovsky, Ilya V.; Acosta, Diana

    2011-01-01

    This paper proposes a control allocation system that can detect and compensate the phase shift between the desired and the actual total control effort due to rate limiting of the actuators. Phase shifting is an important problem in control system applications since it effectively introduces a time delay which may destabilize the closed loop dynamics. A relevant example comes from flight control where aggressive pilot commands, high gain of the flight control system or some anomaly in the system may cause actuator rate limiting and effective time delay introduction. This time delay can instigate Pilot Induced Oscillations (PIO), which is an abnormal coupling between the pilot and the aircraft resulting in unintentional and undesired oscillations. The proposed control allocation system reduces the effective time delay by first detecting the phase shift and then minimizing it using constrained optimization techniques. Flight control simulation results for an unstable aircraft with inertial cross coupling are reported, which demonstrate phase shift minimization and recovery from a PIO event.

  6. Deep Water Munitions Detection System

    DTIC Science & Technology

    2010-03-01

    information if it does not display a currently valid OMB control number. 1. REPORT DATE MAR 2010 2. REPORT TYPE 3. DATES COVERED 00-00-2010 to 00-00...water systems to deeper water depths would result in even greater costs. While some of the cost escalation may be unavoidable, it is desirable to...magnetometers, spaced 61 cm apart, on a towed sensor platform. The sensor platform has active control elements that allow its depth to be changed

  7. One Health and Cyanobacteria in Freshwater Systems: Animal Illnesses and Deaths are Sentinel Events for Human Health Risks

    EPA Science Inventory

    Harmful cyanobacterial blooms have adversely impacted human and animal health for thousands of years. Recently, the health impacts of harmful cyanobacteria blooms are becoming more frequently detected and reported. However, reports of human and animal illnesses or deaths associat...

  8. Reference and Reference Failures. Technical Report No. 398.

    ERIC Educational Resources Information Center

    Goodman, Bradley A.

    In order to build robust natural language processing systems that can detect and recover from miscommunication, the investigation of how people communicate and how they recover from problems in communication described in this artificial intelligence report focused on reference problems which a listener may have in determining what or whom a…

  9. OGLE-IV Transient Search report 07 August 2015

    NASA Astrophysics Data System (ADS)

    Wyrzykowski, L.; Kostrzewa-Rutkowska, Z.; Udalski, A.; Kozlowski, S.; Poleski, R.; Pietrzynski, G.; Sitek, M.

    2015-08-01

    The OGLE-IV Transient Detection System (Wyrzykowski et al. 2014, AcA,64,197; Kozlowski et al. 2013) reports the discovery of 10 new transients. Most of them appeared near or on top of apparent galaxies and their light curves resemble those of supernovae near or after their peak brightness.

  10. Liverpool Telescope Spectroscopy of the Nova Eruption from V392 Persei

    NASA Astrophysics Data System (ADS)

    Darnley, M. J.; Copperwheat, C. M.; Harvey, E. J.; Healy, M. W.

    2018-05-01

    Here we report Liverpool Telescope (LT; Steele et al. 2004) spectroscopy of the recent nova eruption (ATel #11588) from the known dwarf nova system V392 Per. A Fermi & gamma;-ray detection of the eruption has also been reported (ATel #11590) along with additional photometry (ATel #11594).

  11. Small negative cloud-to-ground lightning reports at the NASA Kennedy Space Center and Air Force Eastern Range

    NASA Astrophysics Data System (ADS)

    Wilson, Jennifer G.; Cummins, Kenneth L.; Krider, E. Philip

    2009-12-01

    The NASA Kennedy Space Center (KSC) and Air Force Eastern Range (ER) use data from two cloud-to-ground (CG) lightning detection networks, the Cloud-to-Ground Lightning Surveillance System (CGLSS) and the U.S. National Lightning Detection Network™ (NLDN), and a volumetric lightning mapping array, the Lightning Detection and Ranging (LDAR) system, to monitor and characterize lightning that is potentially hazardous to launch or ground operations. Data obtained from these systems during June-August 2006 have been examined to check the classification of small, negative CGLSS reports that have an estimated peak current, ∣Ip∣ less than 7 kA, and to determine the smallest values of Ip that are produced by first strokes, by subsequent strokes that create a new ground contact (NGC), and by subsequent strokes that remain in a preexisting channel (PEC). The results show that within 20 km of the KSC-ER, 21% of the low-amplitude negative CGLSS reports were produced by first strokes, with a minimum Ip of -2.9 kA; 31% were by NGCs, with a minimum Ip of -2.0 kA; and 14% were by PECs, with a minimum Ip of -2.2 kA. The remaining 34% were produced by cloud pulses or lightning events that we were not able to classify.

  12. Photonic-crystal membranes for optical detection of single nano-particles, designed for biosensor application.

    PubMed

    Grepstad, Jon Olav; Kaspar, Peter; Solgaard, Olav; Johansen, Ib-Rune; Sudbø, Aasmund S

    2012-03-26

    A sensor designed to detect bio-molecules is presented. The sensor exploits a planar 2D photonic crystal (PC) membrane with sub-micron thickness and through holes, to induce high optical fields that allow detection of nano-particles smaller than the diffraction limit of an optical microscope. We report on our design and fabrication of a PC membrane with a nano-particle trapped inside. We have also designed and built an imaging system where an optical microscope and a CCD camera are used to take images of the PC membrane. Results show how the trapped nano-particle appears as a bright spot in the image. In a first experimental realization of the imaging system, single particles with a radius of 75 nm can be detected.

  13. Statin-associated muscular and renal adverse events: data mining of the public version of the FDA adverse event reporting system.

    PubMed

    Sakaeda, Toshiyuki; Kadoyama, Kaori; Okuno, Yasushi

    2011-01-01

    Adverse event reports (AERs) submitted to the US Food and Drug Administration (FDA) were reviewed to assess the muscular and renal adverse events induced by the administration of 3-hydroxy-3-methylglutaryl coenzyme A (HMG-CoA) reductase inhibitors (statins) and to attempt to determine the rank-order of the association. After a revision of arbitrary drug names and the deletion of duplicated submissions, AERs involving pravastatin, simvastatin, atorvastatin, or rosuvastatin were analyzed. Authorized pharmacovigilance tools were used for quantitative detection of signals, i.e., drug-associated adverse events, including the proportional reporting ratio, the reporting odds ratio, the information component given by a Bayesian confidence propagation neural network, and the empirical Bayes geometric mean. Myalgia, rhabdomyolysis and an increase in creatine phosphokinase level were focused on as the muscular adverse events, and acute renal failure, non-acute renal failure, and an increase in blood creatinine level as the renal adverse events. Based on 1,644,220 AERs from 2004 to 2009, signals were detected for 4 statins with respect to myalgia, rhabdomyolysis, and an increase in creatine phosphokinase level, but these signals were stronger for rosuvastatin than pravastatin and atorvastatin. Signals were also detected for acute renal failure, though in the case of atorvastatin, the association was marginal, and furthermore, a signal was not detected for non-acute renal failure or for an increase in blood creatinine level. Data mining of the FDA's adverse event reporting system, AERS, is useful for examining statin-associated muscular and renal adverse events. The data strongly suggest the necessity of well-organized clinical studies with respect to statin-associated adverse events.

  14. HMM Sequential Hypothesis Tests for Intrusion Detection in MANETs Extended Abstract

    DTIC Science & Technology

    2003-01-01

    securing the routing protocols of mobile ad hoc wireless net- works has been done in prevention. Intrusion detection systems play a complimentary...TERMS 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT 18. NUMBER OF PAGES 10 19a. NAME OF RESPONSIBLE PERSON a. REPORT unclassified...hops of A would be unable to communicate with B and vice versa [1]. 1.2 The role of intrusion detection in security In order to provide reliable

  15. Fast methods for analysis of neurotransmitters from single cell and monitoring their releases in central nervous system by capillary electrophoresis, fluorescence microscopy and luminescence imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Ziqiang

    1999-12-10

    Fast methods for separation and detection of important neurotransmitters and the releases in central nervous system (CNS) were developed. Enzyme based immunoassay combined with capillary electrophoresis was used to analyze the contents of amino acid neurotransmitters from single neuron cells. The release of amino acid neurotransmitters from neuron cultures was monitored by laser induced fluorescence imaging method. The release and signal transduction of adenosine triphosphate (ATP) in CNS was studied with sensitive luminescence imaging method. A new dual-enzyme on-column reaction method combined with capillary electrophoresis has been developed for determining the glutamate content in single cells. Detection was based onmore » monitoring the laser-induced fluorescence of the reaction product NADH, and the measured fluorescence intensity was related to the concentration of glutamate in each cell. The detection limit of glutamate is down to 10 -8 M level, which is 1 order of magnitude lower than the previously reported detection limit based on similar detection methods. The mass detection limit of a few attomoles is far superior to that of any other reports. Selectivity for glutamate is excellent over most of amino acids. The glutamate content in single human erythrocyte and baby rat brain neurons were determined with this method and results agreed well with literature values.« less

  16. Governance and One Health: Exploring the Impact of Federalism and Bureaucracy on Zoonotic Disease Detection and Reporting

    PubMed Central

    Allen, Heather A.

    2015-01-01

    The merits of One Health have been thoroughly described in the literature, but how One Health operates in the United States federal system of government is rarely discussed or analyzed. Through a comparative case-study approach, this research explores how federalism, bureaucratic behavior, and institutional design in the United States may influence zoonotic disease outbreak detection and reporting, a key One Health activity. Using theoretical and empirical literature, as well as a survey/interview instrument for individuals directly involved in a past zoonotic disease outbreak, the impacts of governance are discussed. As predicted in the theoretical literature, empirical findings suggest that federalism, institutional design, and bureaucracy may play a role in facilitating or impeding zoonotic disease outbreak detection and reporting. Regulatory differences across states as well as compartmentalization of information within agencies may impede disease detection. However, the impact may not always be negative: bureaucracies can also be adaptive; federalism allows states important opportunities for innovation. While acknowledging there are many other factors that also matter in zoonotic disease detection and reporting, this research is one of the first attempts to raise awareness in the literature and stimulate discussion on the intersection of governance and One Health. PMID:29061932

  17. Evaluation of 'SAEFVIC', A Pharmacovigilance Surveillance Scheme for the Spontaneous Reporting of Adverse Events Following Immunisation in Victoria, Australia.

    PubMed

    Clothier, Hazel J; Crawford, Nigel W; Russell, Melissa; Kelly, Heath; Buttery, Jim P

    2017-06-01

    Australia is traditionally an early adopter of vaccines, therefore comprehensive and effective post-licensure vaccine pharmacovigilance is critical to maintain confidence in immunisation, both nationally and internationally. With adverse event following immunisation (AEFI) surveillance the responsibility of Australian jurisdictions, Victoria operates an enhanced passive AEFI surveillance system integrated with clinical services, called 'SAEFVIC' (Surveillance of Adverse Events Following Vaccination In the Community). The aim of this study was to evaluate Victoria's current AEFI surveillance system 'SAEFVIC' and inform ongoing quality improvement of vaccine pharmacovigilance in Victoria and Australia. We conducted a retrospective structured desktop evaluation of AEFI reporting received by SAEFVIC from 2007 to 2014, to evaluate the system according to its stated objectives, i.e. to improve AEFI reporting; provide AEFI signal detection; and to maintain consumer confidence in vaccination. AEFI reporting has tripled since SAEFVIC commenced (incidence risk ratio [IRR] 3.04, 95% confidence interval [CI] 2.35-3.93), raising Victoria to be the lead jurisdiction by AEFI reporting volume and to rank third by population reporting rate nationally. The largest increase was observed in children. Data were utilised to investigate potential signal events and inform vaccine policy. Signal detection required clinical suspicion by surveillance nurses, or prior vaccine-specific concerns. Subsequent vaccination post-AEFI was documented for 56.2% (95% CI 54.1-58.4) of reports, and the proportion of children due or overdue for vaccination was 2.3% higher for those reporting AEFI compared with the general population. SAEFVIC has improved AEFI surveillance, facilitates signal investigation and validation, and supports consumer confidence in immunisation. Expansion of the system nationally has the potential to improve capacity and capability of vaccine pharmacovigilance, particularly through data consistency and jurisdictional comparability in Australia.

  18. Conceptual design of a hybrid neutron-gamma detector for study of β-delayed neutrons at the RIB facility of RIKEN

    NASA Astrophysics Data System (ADS)

    Tarifeño-Saldivia, A.; Tain, J. L.; Domingo-Pardo, C.; Calviño, F.; Cortés, G.; Phong, V. H.; Riego, A.; Agramunt, J.; Algora, A.; Brewer, N.; Caballero-Folch, R.; Coleman-Smith, P. J.; Davinson, T.; Dillmann, I.; Estradé, A.; Griffin, C. J.; Grzywacz, R.; Harkness-Brennan, L. J.; Kiss, G. G.; Kogimtzis, M.; Labiche, M.; Lazarus, I. H.; Lorusso, G.; Matsui, K.; Miernik, K.; Montes, F.; Morales, A. I.; Nishimura, S.; Page, R. D.; Podolyák, Z. S.; Pucknell, V. F. E.; Rasco, B. C.; Regan, P.; Rubio, B.; Rykaczewski, K. P.; Saito, Y.; Sakurai, H.; Simpson, J.; Sokol, E.; Surman, R.; Svirkhin, A.; Thomas, S. L.; Tolosa, A.; Woods, P.

    2017-04-01

    The conceptual design of the BRIKEN neutron detector at the radioactive ion beam factory (RIBF) of the RIKEN Nishina Center is reported. The BRIKEN setup is a complex system aimed at detecting heavy-ion implants, β particles, γ rays and β-delayed neutrons. The whole setup includes the Advanced Implantation Detection Array (AIDA), two HPGe Clover detectors and up to 166 3He-filled counters embedded in a high-density polyethylene moderator. The design is quite complex due to the large number and different types of 3He-tubes involved and the additional constraints introduced by the ancillary detectors for charged particles and γ rays. This article reports on a novel methodology developed for the conceptual design and optimisation of the 3He-counter array, aiming for the best possible performance in terms of neutron detection. The algorithm is based on a geometric representation of two selected detector parameters of merit, namely, the average neutron detection efficiency and the efficiency flatness as a function of a reduced number of geometric variables. The response of the neutron detector is obtained from a systematic Monte Carlo simulation implemented in GEANT4. The robustness of the algorithm allowed us to design a versatile detection system, which operated in hybrid mode includes the full neutron counter and two clover detectors for high-precision gamma spectroscopy. In addition, the system can be reconfigured into a compact mode by removing the clover detectors and re-arranging the 3He tubes in order to maximize the neutron detection performance. Both operation modes shows a rather flat and high average efficiency. In summary, we have designed a system which shows an average efficiency for hybrid mode (3He tubes + clovers) of 68.6% and 64% for neutron energies up to 1 and 5 MeV, respectively. For compact mode (only 3He tubes), the average efficiency is 75.7% and 71% for neutron energies up to 1 and 5 MeV, respectively. The performance of the BRIKEN detection system has been also quantified by means of Monte Carlo simulations with different neutron energy distributions.

  19. Screening of diabetics for retinopathy by ophthalmic opticians.

    PubMed Central

    Burns-Cox, C J; Hart, J C

    1985-01-01

    Diabetes mellitus is a major cause of blindness in England and Wales in those aged between 30 and 64. Photocoagulation can frequently prevent blindness provided the retinopathy is detected at an appropriate stage but unfortunately the benefits are small if the changes are advanced. Early detection of diabetic retinopathy by regular examination is needed. We have shown that ophthalmic opticians have the skill to detect retinal changes at a treatable stage. Out of 844 eye checks, 80 were reported by ophthalmic opticians to justify referral to an ophthalmologist and 20 of these required photocoagulation treatment. Of a sample of 197 patients rechecked by an ophthalmologist reported by ophthalmic opticians not to justify referral, only one needed treatment. With local agreement this system of detecting retinopathy could be easily applied anywhere in the United Kingdom. No extra personnel or facilities are needed. PMID:3921106

  20. Screening of diabetics for retinopathy by ophthalmic opticians.

    PubMed

    Burns-Cox, C J; Hart, J C

    1985-04-06

    Diabetes mellitus is a major cause of blindness in England and Wales in those aged between 30 and 64. Photocoagulation can frequently prevent blindness provided the retinopathy is detected at an appropriate stage but unfortunately the benefits are small if the changes are advanced. Early detection of diabetic retinopathy by regular examination is needed. We have shown that ophthalmic opticians have the skill to detect retinal changes at a treatable stage. Out of 844 eye checks, 80 were reported by ophthalmic opticians to justify referral to an ophthalmologist and 20 of these required photocoagulation treatment. Of a sample of 197 patients rechecked by an ophthalmologist reported by ophthalmic opticians not to justify referral, only one needed treatment. With local agreement this system of detecting retinopathy could be easily applied anywhere in the United Kingdom. No extra personnel or facilities are needed.

  1. ESARR: enhanced situational awareness via road sign recognition

    NASA Astrophysics Data System (ADS)

    Perlin, V. E.; Johnson, D. B.; Rohde, M. M.; Lupa, R. M.; Fiorani, G.; Mohammad, S.

    2010-04-01

    The enhanced situational awareness via road sign recognition (ESARR) system provides vehicle position estimates in the absence of GPS signal via automated processing of roadway fiducials (primarily directional road signs). Sign images are detected and extracted from vehicle-mounted camera system, and preprocessed and read via a custom optical character recognition (OCR) system specifically designed to cope with low quality input imagery. Vehicle motion and 3D scene geometry estimation enables efficient and robust sign detection with low false alarm rates. Multi-level text processing coupled with GIS database validation enables effective interpretation even of extremely low resolution low contrast sign images. In this paper, ESARR development progress will be reported on, including the design and architecture, image processing framework, localization methodologies, and results to date. Highlights of the real-time vehicle-based directional road-sign detection and interpretation system will be described along with the challenges and progress in overcoming them.

  2. Real-Time Continuous Identification of Greenhouse Plant Pathogens Based on Recyclable Microfluidic Bioassay System.

    PubMed

    Qu, Xiangmeng; Li, Min; Zhang, Hongbo; Lin, Chenglie; Wang, Fei; Xiao, Mingshu; Zhou, Yi; Shi, Jiye; Aldalbahi, Ali; Pei, Hao; Chen, Hong; Li, Li

    2017-09-20

    The development of a real-time continuous analytical platform for the pathogen detection is of great scientific importance for achieving better disease control and prevention. In this work, we report a rapid and recyclable microfluidic bioassay system constructed from oligonucleotide arrays for selective and sensitive continuous identification of DNA targets of fungal pathogens. We employ the thermal denaturation method to effectively regenerate the oligonucleotide arrays for multiple sample detection, which could considerably reduce the screening effort and costs. The combination of thermal denaturation and laser-induced fluorescence detection technique enables real-time continuous identification of multiple samples (<10 min per sample). As a proof of concept, we have demonstrated that two DNA targets of fungal pathogens (Botrytis cinerea and Didymella bryoniae) can be sequentially analyzed using our rapid microfluidic bioassay system, which provides a new paradigm in the design of microfluidic bioassay system and will be valuable for chemical and biomedical analysis.

  3. Microfluidics-based integrated airborne pathogen detection systems

    NASA Astrophysics Data System (ADS)

    Northrup, M. Allen; Alleman-Sposito, Jennifer; Austin, Todd; Devitt, Amy; Fong, Donna; Lin, Phil; Nakao, Brian; Pourahmadi, Farzad; Vinas, Mary; Yuan, Bob

    2006-09-01

    Microfluidic Systems is focused on building microfluidic platforms that interface front-end mesofluidics to handle real world sample volumes for optimal sensitivity coupled to microfluidic circuitry to process small liquid volumes for complex reagent metering, mixing, and biochemical analysis, particularly for pathogens. MFSI is the prime contractor on two programs for the US Department of Homeland Security: BAND (Bioagent Autonomous Networked Detector) and IBADS (Instantaneous Bio-Aerosol Detection System). The goal of BAND is to develop an autonomous system for monitoring the air for known biological agents. This consists of air collection, sample lysis, sample purification, detection of DNA, RNA, and toxins, and a networked interface to report the results. For IBADS, MFSI is developing the confirmatory device which must verify the presence of a pathogen with 5 minutes of an air collector/trigger sounding an alarm. Instrument designs and biological assay results from both BAND and IBADS will be presented.

  4. Engineering bacteriophage for a pragmatic low-resource setting bacterial diagnostic platform.

    PubMed

    Talbert, Joey N; Alcaine, Samuel D; Nugen, Sam R

    2016-04-01

    Bacteriophages represent multifaceted building blocks that can be incorporated as substitutes for, or in unison with other detection methods, to create powerful new diagnostics for the detection of bacteria. The ease of phage manipulation, production, and detection speed clearly highlights that there remains unrealized opportunities to leverage these phage-based components in diagnostics amenable to resource-limited settings. The passage of regulations like the Food Safety Modernization act, and the ever increasing extent of global trade and travel, will create further demand for these types of diagnostics. While phage-based diagnostics have begun to entering the market place, further research is needed to ensure the potential benefits of phage-based technologies for public health are fully realized. We are just beginning to explore the possibilities that phage-based detection can offer us in the future. The combination of engineered phages as well as engineered enzymes could result in ultrasensitive detection systems for low-resource settings. Because the reporter enzyme is synthesized in vivo, we need to consider the options outside of normal enzyme reporters. In this case, common enzyme issues such as purification and long-term stability are less important. Phage-based diagnostics were conceptualized from out-of-the box thinking and the evolution of these systems should be as well.

  5. A Survey on Pharmacovigilance Activities in ASEAN and Selected Non-ASEAN Countries, and the Use of Quantitative Signal Detection Algorithms.

    PubMed

    Chan, Cheng Leng; Ang, Pei San; Li, Shu Chuen

    2017-06-01

    Most Countries have pharmacovigilance (PV) systems in place to monitor the safe use of health products. The process involves the detection and assessment of safety issues from various sources of information, communicating the risk to stakeholders and taking other relevant risk minimization measures. This study aimed to assess the PV status in Association of Southeast Asian Nation (ASEAN) countries, sources for postmarket safety monitoring, methods used for signal detection and the need for a quantitative signal detection algorithm (QSDA). Comparisons were conducted with centres outside ASEAN. A questionnaire was sent to all PV centres in ASEAN countries, as well as seven other countries, from November 2015 to June 2016. The questionnaire was designed to collect information on the status of PV, with a focus on the use of a QSDA. Data were collected from nine ASEAN countries and seven other countries. PV activities were conducted in all these countries, which were at different stages of development. In terms of adverse drug reaction (ADR) reports, the average number received per year ranged from 3 to 50,000 reports for ASEAN countries and from 7000 to 1,103,200 for non-ASEAN countries. Thirty-three percent of ASEAN countries utilized statistical methods to help detect signals from ADR reports compared with 100% in the other non-ASEAN countries. Eighty percent agreed that the development of a QSDA would help in drug signal detection. The main limitation identified was the lack of knowledge and/or lack of resources. Spontaneous ADR reports from healthcare professionals remains the most frequently used source for safety monitoring. The traditional method of case-by-case review of ADR reports prevailed for signal detection in ASEAN countries. As the reports continue to grow, the development of a QSDA would be useful in helping detect safety signals.

  6. StopWatch: The preliminary evaluation of a smartwatch-based system for passive detection of cigarette smoking.

    PubMed

    Skinner, Andrew L; Stone, Christopher J; Doughty, Hazel; Munafò, Marcus R

    2018-01-24

    Recent developments in smoking cessation support systems and interventions have highlighted the requirement for unobtrusive, passive ways to measure smoking behaviour. A number of systems have been developed for this that either use bespoke sensing technology, or expensive combinations of wearables and smartphones. Here we present StopWatch, a system for passive detection of cigarette smoking that runs on a low-cost smartwatch and does not require additional sensing or a connected smartphone. Our system uses motion data from the accelerometer and gyroscope in an Android smartwatch to detect the signature hand movements of cigarette smoking. It uses machine learning techniques to transform raw motion data into motion features, and in turn into individual drags and instances of smoking. These processes run on the smartwatch, and do not require a smartphone. We conducted preliminary validations of the system in daily smokers (n=13) in laboratory and free-living conditions running on an Android LG G-Watch. In free-living conditions, over a 24-hour period, the system achieved precision of 86% and recall of 71%. StopWatch is a system for passive measurement of cigarette smoking that runs entirely on a commercially available Android smartwatch. It requires no smartphone so the cost is low, and needs no bespoke sensing equipment so participant burden is also low. Performance is currently lower than other more expensive and complex systems, though adequate for some applications. Future developments will focus on enhancing performance, validation on a range of smartwatches, and detection of electronic cigarette use. We present a low-cost, smartwatch-based system for passive detection of cigarette smoking. It uses data from the motion sensors in the watch to identify the signature hand movements of cigarette smoking. The system will provide the detailed measures of individual smoking behaviour needed for context-triggered just-in-time smoking cessation support systems, and to enable just-in-time adaptive interventions. More broadly, the system will enable researchers to obtain detailed measures of individual smoking behaviour in free-living conditions that are free from the recall errors and reporting biases associated with self-report of smoking. © The Author(s) 2018. Published by Oxford University Press on behalf of the Society for Research on Nicotine and Tobacco.

  7. Flexibility in Visual Working Memory: Accurate Change Detection in the Face of Irrelevant Variations in Position

    PubMed Central

    Woodman, Geoffrey F.; Vogel, Edward K.; Luck, Steven J.

    2012-01-01

    Many recent studies of visual working memory have used change-detection tasks in which subjects view sequential displays and are asked to report whether they are identical or if one object has changed. A key question is whether the memory system used to perform this task is sufficiently flexible to detect changes in object identity independent of spatial transformations, but previous research has yielded contradictory results. To address this issue, the present study compared standard change-detection tasks with tasks in which the objects varied in size or position between successive arrays. Performance was nearly identical across the standard and transformed tasks unless the task implicitly encouraged spatial encoding. These results resolve the discrepancies in prior studies and demonstrate that the visual working memory system can detect changes in object identity across spatial transformations. PMID:22287933

  8. Discovery of high-energy gamma-ray emission from the binary system PSR B1259–63/LS 2883 around periastron with Fermi

    DOE PAGES

    Abdo, A. A.; Ackermann, M.; Ajello, M.; ...

    2011-06-28

    Here, we report on the discovery of ≥ 100 MeV rays from the binary system PSR B12596–3/LS 2883 using the Large Area Telescope (LAT) on board Fermi. The system comprises a radio pulsar in orbit around a Be star. We report on LAT observations from near apastron to ~60 days after the time of periastron, t p, on 2010 December 15. No γ-ray emission was detected from this source when it was far from periastron.

  9. Smartphone-based sensing system using ZnO and graphene modified electrodes for VOCs detection.

    PubMed

    Liu, Lei; Zhang, Diming; Zhang, Qian; Chen, Xing; Xu, Gang; Lu, Yanli; Liu, Qingjun

    2017-07-15

    Volatile organic compounds (VOCs) detection is in high demand for clinic treatment, environment monitoring, and food quality control. Especially, VOCs from human exhaled breath can serve as significant biomarkers of some diseases, such as lung cancer and diabetes. In this study, a smartphone-based sensing system was developed for real-time VOCs monitoring using alternative current (AC) impedance measurement. The interdigital electrodes modified with zinc oxide (ZnO), graphene, and nitrocellulose were used as sensors to produce impedance responses to VOCs. The responses could be detected by a hand-held device, sent out to a smartphone by Bluetooth, and reported with concentration on an android program of the smartphone. The smartphone-based system was demonstrated to detect acetone at concentrations as low as 1.56ppm, while AC impedance spectroscopy was used to distinguish acetone from other VOCs. Finally, measurements of the exhalations from human being were carried out to obtain the concentration of acetone in exhaled breath before and after exercise. The results proved that the smartphone-based system could be applied on the detection of VOCs in real settings for healthcare diagnosis. Thus, the smartphone-based system for VOCs detection provided a convenient, portable and efficient approach to monitor VOCs in exhaled breath and possibly allowed for early diagnosis of some diseases. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. A Novel Pretreatment-Free Duplex Chamber Digital PCR Detection System for the Absolute Quantitation of GMO Samples.

    PubMed

    Zhu, Pengyu; Wang, Chenguang; Huang, Kunlun; Luo, Yunbo; Xu, Wentao

    2016-03-18

    Digital polymerase chain reaction (PCR) has developed rapidly since it was first reported in the 1990s. However, pretreatments are often required during preparation for digital PCR, which can increase operation error. The single-plex amplification of both the target and reference genes may cause uncertainties due to the different reaction volumes and the matrix effect. In the current study, a quantitative detection system based on the pretreatment-free duplex chamber digital PCR was developed. The dynamic range, limit of quantitation (LOQ), sensitivity and specificity were evaluated taking the GA21 event as the experimental object. Moreover, to determine the factors that may influence the stability of the duplex system, we evaluated whether the pretreatments, the primary and secondary structures of the probes and the SNP effect influence the detection. The results showed that the LOQ was 0.5% and the sensitivity was 0.1%. We also found that genome digestion and single nucleotide polymorphism (SNP) sites affect the detection results, whereas the unspecific hybridization within different probes had little side effect. This indicated that the detection system was suited for both chamber-based and droplet-based digital PCR. In conclusion, we have provided a simple and flexible way of achieving absolute quantitation for genetically modified organism (GMO) genome samples using commercial digital PCR detection systems.

  11. A Novel Pretreatment-Free Duplex Chamber Digital PCR Detection System for the Absolute Quantitation of GMO Samples

    PubMed Central

    Zhu, Pengyu; Wang, Chenguang; Huang, Kunlun; Luo, Yunbo; Xu, Wentao

    2016-01-01

    Digital polymerase chain reaction (PCR) has developed rapidly since it was first reported in the 1990s. However, pretreatments are often required during preparation for digital PCR, which can increase operation error. The single-plex amplification of both the target and reference genes may cause uncertainties due to the different reaction volumes and the matrix effect. In the current study, a quantitative detection system based on the pretreatment-free duplex chamber digital PCR was developed. The dynamic range, limit of quantitation (LOQ), sensitivity and specificity were evaluated taking the GA21 event as the experimental object. Moreover, to determine the factors that may influence the stability of the duplex system, we evaluated whether the pretreatments, the primary and secondary structures of the probes and the SNP effect influence the detection. The results showed that the LOQ was 0.5% and the sensitivity was 0.1%. We also found that genome digestion and single nucleotide polymorphism (SNP) sites affect the detection results, whereas the unspecific hybridization within different probes had little side effect. This indicated that the detection system was suited for both chamber-based and droplet-based digital PCR. In conclusion, we have provided a simple and flexible way of achieving absolute quantitation for genetically modified organism (GMO) genome samples using commercial digital PCR detection systems. PMID:26999129

  12. Real-time biochemical sensor based on Raman scattering with CMOS contact imaging.

    PubMed

    Muyun Cao; Yuhua Li; Yadid-Pecht, Orly

    2015-08-01

    This work presents a biochemical sensor based on Raman scattering with Complementary metal-oxide-semiconductor (CMOS) contact imaging. This biochemical optical sensor is designed for detecting the concentration of solutions. The system is built with a laser diode, an optical filter, a sample holder and a commercial CMOS sensor. The output of the system is analyzed by an image processing program. The system provides instant measurements with a resolution of 0.2 to 0.4 Mol. This low cost and easy-operated small scale system is useful in chemical, biomedical and environmental labs for quantitative bio-chemical concentration detection with results reported comparable to a highly cost commercial spectrometer.

  13. The design and integration of retinal CAD-SR to diabetes patient ePR system

    NASA Astrophysics Data System (ADS)

    Wu, Huiqun; Wei, Yufang; Liu, Brent J.; Shang, Yujuan; Shi, Lili; Jiang, Kui; Dong, Jiancheng

    2017-03-01

    Diabetic retinopathy (DR) is one of the serious complications of diabetes that could lead to blindness. Digital fundus camera is often used to detect retinal changes but the diagnosis relies too much on ophthalmologist's experience. Based on our previously developed algorithms for quantifying retinal vessels and lesions, we developed a computer aided detection-structured report (CAD-SR) template and implemented it into picture archiving and communication system (PACS). Furthermore, we mapped our CAD-SR into HL7 CDA to integrate CAD findings into diabetes patient electronic patient record (ePR) system. Such integration could provide more quantitative features from fundus image into ePR system, which is valuable for further data mining researches.

  14. Analysis of variation in oil pressure in lubricating system

    NASA Astrophysics Data System (ADS)

    Sharma, Sumit; Upreti, Mritunjay; Sharma, Bharat; Poddar, Keshav

    2018-05-01

    Automotive Maintenance for an engine contributes to its reliability, energy efficiency and repair cost reduction. Modeling of engine performance and fault detection require large amount of data, which are usually obtained on test benches. This report presents a methodical study on analysis of variation in lubrication system of various medium speed engines. Further this study is limited to the influence of Engine Oil Pressure on frictional losses, Torque analysis for various Oil Pressures and an analytical analysis of engine Lubrication System. The data collected from various Engines under diagnostics is represented graphically. Finally the illustrated results were used as a viable source for detection and troubleshooting of faults in Lubrication System of regular passenger vehicle.

  15. Optofluidic platforms based on surface-enhanced Raman scattering.

    PubMed

    Lim, Chaesung; Hong, Jongin; Chung, Bong Geun; deMello, Andrew J; Choo, Jaebum

    2010-05-01

    We report recent progress in the development of surface-enhanced Raman scattering (SERS)-based optofluidic platforms for the fast and sensitive detection of chemical and biological analytes. In the current context, a SERS-based optofluidic platform is defined as an integrated analytical device composed of a microfluidic element and a sensitive Raman spectrometer. Optofluidic devices for SERS detection normally involve nanocolloid-based microfluidic systems or metal nanostructure-embedded microfluidic systems. In the current review, recent advances in both approaches are surveyed and assessed. Additionally, integrated real-time sensing systems that combine portable Raman spectrometers with microfluidic devices are also reviewed. Such real-time sensing systems have significant utility in environmental monitoring, forensic science and homeland defense applications.

  16. EVALUATION OF SENSOR AND MONITORS TO DETECT CHANGES IN WATER QUALITY

    EPA Science Inventory

    The safety and security of distribution systems has come under reassessment in the past year. Several chemical and biological agents have been identified that might constitute a credible threat against water supply systems. There have also been a few reported threats against wate...

  17. Development of a remote sensing network for time-sensitive detection of fine scale damage to transportation infrastructure : [final report].

    DOT National Transportation Integrated Search

    2015-09-23

    This research project aimed to develop a remote sensing system capable of rapidly identifying fine-scale damage to critical transportation infrastructure following hazard events. Such a system must be pre-planned for rapid deployment, automate proces...

  18. Phase II, Compact AMS System for Biological Tracer Detection Final Report CRADA No. TSV-1533-96

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brown, T. A.; Hamm, R. W.

    2017-11-01

    The objective of this collaboration between LLNL and AccSys Technology, Inc. of Pleasanton, California was to build and demonstrate a low cost, compact tritium (3H) Accelerator Mass Spectrometer (AMS) system matched to the requirements of biomedical research.

  19. Animal-vehicle crash mitigation using advanced technology : phase II, system effectiveness and system acceptance.

    DOT National Transportation Integrated Search

    2009-03-01

    This project was initiated in the fall of 1999. The results through the fall of 2005 (Phase I) have been documented in detail in an earlier report. The accomplishments of Phase I included the following: the identification of existing animal detection...

  20. Development of a Calibration Strip for Immunochromatographic Assay Detection Systems.

    PubMed

    Gao, Yue-Ming; Wei, Jian-Chong; Mak, Peng-Un; Vai, Mang-I; Du, Min; Pun, Sio-Hang

    2016-06-29

    With many benefits and applications, immunochromatographic (ICG) assay detection systems have been reported on a great deal. However, the existing research mainly focuses on increasing the dynamic detection range or application fields. Calibration of the detection system, which has a great influence on the detection accuracy, has not been addressed properly. In this context, this work develops a calibration strip for ICG assay photoelectric detection systems. An image of the test strip is captured by an image acquisition device, followed by performing a fuzzy c-means (FCM) clustering algorithm and maximin-distance algorithm for image segmentation. Additionally, experiments are conducted to find the best characteristic quantity. By analyzing the linear coefficient, an average value of hue (H) at 14 min is chosen as the characteristic quantity and the empirical formula between H and optical density (OD) value is established. Therefore, H, saturation (S), and value (V) are calculated by a number of selected OD values. Then, H, S, and V values are transferred to the RGB color space and a high-resolution printer is used to print the strip images on cellulose nitrate membranes. Finally, verification of the printed calibration strips is conducted by analyzing the linear correlation between OD and the spectral reflectance, which shows a good linear correlation (R² = 98.78%).

  1. Development of a wireless, self-sustaining damage detection sensor system based on chemiluminescence for structural health monitoring

    NASA Astrophysics Data System (ADS)

    Kuang, K. S. C.

    2014-03-01

    A novel application of chemiluminescence resulting from the chemical reaction in a glow-stick as sensors for structural health monitoring is demonstrated here. By detecting the presence of light emitting from these glow-sticks, it is possible to develop a low-cost sensing device with the potential to provide early warning of damage in a variety of engineering applications such as monitoring of cracks or damage in concrete shear walls, detecting of ground settlement, soil liquefaction, slope instability, liquefaction-related damage of underground structure and others. In addition, this paper demonstrates the ease of incorporating wireless capability to the sensor device and the possibility of making the sensor system self-sustaining by means of a renewable power source for the wireless module. A significant advantage of the system compared to previous work on the use of plastic optical fibre (POF) for damage detection is that here the system does not require an electrically-powered light source. Here, the sensing device, embedded in a cement host, is shown to be capable of detecting damage. A series of specimens with embedded glow-sticks have been investigated and an assessment of their damage detection capability will be reported. The specimens were loaded under flexure and the sensor responses were transmitted via a wireless connection.

  2. Results of the rubella elimination program in Catalonia (Spain), 2002–2011

    PubMed Central

    Barrabeig, Irene; Torner, Nuria; Martínez, Ana; Carmona, Gloria; Ciruela, Pilar; Batalla, Joan; Costa, Josep; Hernández, Sergi; Salleras, Luis; Domínguez, Angela; Group of Catalonia, the Rubella Surveillance

    2013-01-01

    Rubella is usually a mild disease with nonspecific symptoms, but can cause congenital rubella syndrome (CRS) when infection occurs during pregnancy. The objective of this study was to evaluate the sensitivity and positive predictive value of different data sources used for surveillance purposes in the Rubella Elimination Program of Catalonia between 2002 and 2011. The Urgent Notification to the Statutory Disease Reporting System, the Individualized Disease Reporting System, screening for other viruses included in the Measles Elimination Program, the Microbiological Reporting System and the Minimum Hospital Discharge Data were evaluated. 100 suspected cases of postnatal rubella and 6 suspected cases of CRS were detected. For postnatal rubella, Urgent Notification had the highest sensitivity (32.5%; 95%CI 18.6–49.1), followed by the Virus screening in Measles Elimination Program (25%; 95%CI 12.7-41.2). Virus screening in the Measles Elimination Program had the highest PPV (76.9%; 95%CI 46.1–94.9), followed by the Individualized Disease Reporting System (57.1%; 95%CI 28.9–82.3). For CRS cases, the Individualized Disease Reporting System had the highest sensitivity (100%, 95%CI 29.2–100) and the highest PPV (60%; 95%CI 14.7–100). Most confirmed postnatal cases (25 cases, 48.1%) were in the 25–44 y age group followed by the 15–24 y age group (11 cases, 21.2%). The highest values of sensitivity and PPV for the detection of confirmed cases corresponded to activities that were specifically introduced in the measles and rubella elimination programs. PMID:23299566

  3. 78 FR 68688 - Airworthiness Directives; EADS CASA (Type Certificate Previously Held by Construcciones...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-15

    ... fuel transfer system. We are issuing this AD to detect and correct damage to certain fuel booster pumps... problem with the fuel transfer system. The results of the subsequent investigation revealed damage on the... was prompted by a report of an in-flight problem with the fuel transfer system. We are issuing this AD...

  4. The Practical Relevance of Accountability Systems for School Improvement: A Descriptive Analysis of California Schools. CSE Report 713

    ERIC Educational Resources Information Center

    Mintrop, Heinrich; Trujillo, Tina

    2007-01-01

    In search for the practical relevance of accountability systems for school improvement, we ask whether practitioners traveling between the worlds of system-designated high and low-performing schools would detect tangible differences by observing concrete behaviors, looking at student work, or inquiring about teacher, administrator, or student…

  5. Photodynamic therapy using 5-aminolevulinic acid-induced photosensitization: current clinical status

    NASA Astrophysics Data System (ADS)

    Marcus, Stuart L.; Golub, Allyn L.; Shulman, D. Geoffrey

    1995-03-01

    Photodynamic therapy using 5-aminolevulinic acid-induced photosensitization (ALA PDT) via endogenous protoporphyrin IX (PpIX) synthesis has been reported as efficacious, using topical formulations, in the treatment of a variety of dermatologic diseases including superficial basal cell carcinoma, Bowen's disease, and actinic (solar) keratoses. Application of ALA PDT to the detection and treatment of both malignant and non-malignant diseases of internal organs has recently been reported. Local internal application of ALA has been used for the detection, via PpIX fluorescence, of pathological conditions of the human urinary bladder and for selective endometrial ablation in animal model systems. Systemic, oral administration of ALA has been used for ALA PDT of superficial head and neck cancer and of colorectal cancer. This paper reviews the current clinical status of ALA PDT.

  6. APDS: the autonomous pathogen detection system.

    PubMed

    Hindson, Benjamin J; Makarewicz, Anthony J; Setlur, Ujwal S; Henderer, Bruce D; McBride, Mary T; Dzenitis, John M

    2005-04-15

    We have developed and tested a fully autonomous pathogen detection system (APDS) capable of continuously monitoring the environment for airborne biological threat agents. The system was developed to provide early warning to civilians in the event of a bioterrorism incident and can be used at high profile events for short-term, intensive monitoring or in major public buildings or transportation nodes for long-term monitoring. The APDS is completely automated, offering continuous aerosol sampling, in-line sample preparation fluidics, multiplexed detection and identification immunoassays, and nucleic acid-based polymerase chain reaction (PCR) amplification and detection. Highly multiplexed antibody-based and duplex nucleic acid-based assays are combined to reduce false positives to a very low level, lower reagent costs, and significantly expand the detection capabilities of this biosensor. This article provides an overview of the current design and operation of the APDS. Certain sub-components of the ADPS are described in detail, including the aerosol collector, the automated sample preparation module that performs multiplexed immunoassays with confirmatory PCR, and the data monitoring and communications system. Data obtained from an APDS that operated continuously for 7 days in a major U.S. transportation hub is reported.

  7. Interference and differentiation of the neighboring surface microcracks in distributed sensing with PPP-BOTDA.

    PubMed

    Meng, Dewei; Ansari, Farhad

    2016-12-01

    Detection of cracks while at their early stages of evolution is important in health monitoring of civil structures. Review of technical literature reveals that single or sparsely distributed multiple cracks can be detected by Brillouin-scattering-based optical fiber sensor systems. In a recent study, a pre-pump-pulse Brillouin optical time-domain analysis (PPP-BOTDA) system was employed for detection of a single microcrack. Specific characteristics of the Brillouin gain spectrum, such as Brillouin frequency shift, and Brillouin gain spectrum width, were utilized in order to detect the formation and growth of microcracks with crack opening displacements as small as 25 μm. In most situations, formations of neighboring microcracks are not detected due to inherent limitations of Brillouin-based systems. In the study reported here, the capability of PPP-BOTDA for detection of two neighboring microcracks was investigated in terms of the proximity of the microcracks with respect to each other, i.e., crack spacing distance, crack opening displacement, and the spatial resolution of the PPP-BOTDA. The extent of the study pertained both to theoretical as well as experimental investigations. The concept of shape index is introduced in order to establish an analytical method for gauging the influence of the neighboring microcracks in detection and microcrack differentiation capabilities of Brillouin-based optical fiber sensor systems.

  8. Syndromic Surveillance Using Veterinary Laboratory Data: Algorithm Combination and Customization of Alerts

    PubMed Central

    Dórea, Fernanda C.; McEwen, Beverly J.; McNab, W. Bruce; Sanchez, Javier; Revie, Crawford W.

    2013-01-01

    Background Syndromic surveillance research has focused on two main themes: the search for data sources that can provide early disease detection; and the development of efficient algorithms that can detect potential outbreak signals. Methods This work combines three algorithms that have demonstrated solid performance in detecting simulated outbreak signals of varying shapes in time series of laboratory submissions counts. These are: the Shewhart control charts designed to detect sudden spikes in counts; the EWMA control charts developed to detect slow increasing outbreaks; and the Holt-Winters exponential smoothing, which can explicitly account for temporal effects in the data stream monitored. A scoring system to detect and report alarms using these algorithms in a complementary way is proposed. Results The use of multiple algorithms in parallel resulted in increased system sensitivity. Specificity was decreased in simulated data, but the number of false alarms per year when the approach was applied to real data was considered manageable (between 1 and 3 per year for each of ten syndromic groups monitored). The automated implementation of this approach, including a method for on-line filtering of potential outbreak signals is described. Conclusion The developed system provides high sensitivity for detection of potential outbreak signals while also providing robustness and flexibility in establishing what signals constitute an alarm. This flexibility allows an analyst to customize the system for different syndromes. PMID:24349216

  9. Syndromic surveillance using veterinary laboratory data: algorithm combination and customization of alerts.

    PubMed

    Dórea, Fernanda C; McEwen, Beverly J; McNab, W Bruce; Sanchez, Javier; Revie, Crawford W

    2013-01-01

    Syndromic surveillance research has focused on two main themes: the search for data sources that can provide early disease detection; and the development of efficient algorithms that can detect potential outbreak signals. This work combines three algorithms that have demonstrated solid performance in detecting simulated outbreak signals of varying shapes in time series of laboratory submissions counts. These are: the Shewhart control charts designed to detect sudden spikes in counts; the EWMA control charts developed to detect slow increasing outbreaks; and the Holt-Winters exponential smoothing, which can explicitly account for temporal effects in the data stream monitored. A scoring system to detect and report alarms using these algorithms in a complementary way is proposed. The use of multiple algorithms in parallel resulted in increased system sensitivity. Specificity was decreased in simulated data, but the number of false alarms per year when the approach was applied to real data was considered manageable (between 1 and 3 per year for each of ten syndromic groups monitored). The automated implementation of this approach, including a method for on-line filtering of potential outbreak signals is described. The developed system provides high sensitivity for detection of potential outbreak signals while also providing robustness and flexibility in establishing what signals constitute an alarm. This flexibility allows an analyst to customize the system for different syndromes.

  10. Miniaturized, multibeam, solid state scanning laser radar in automobile collision avoidance sensor systems

    NASA Astrophysics Data System (ADS)

    Sargent, Ronald A.

    1995-06-01

    Recent intelligent transportation systems (ITS) initiatives sponsored by commercial transportation companies and the U.S. Department of Transportation include an area dedicated to Automated Vehicle Control Systems (AVCS). AVCS systems are dedicated to improving passenger automobile safety, efficiency, and impact on the environment. Minimizing the number of automobile collisions through automated obstacle detection and vehicle response is vital to this effort. Simple, reliable, low cost sensors installed in automobiles to provide driver warning and/or input to vehicle systems such as braking or cruise control are the key piece to making this technology as common as air bags and seat belts. EPA emission regulations now require specific areas to periodically report the mix of vehicle types. These reports must include in the mix the 13 possible categories for vehicles. Simple low cost senors installed as part of the traffic management system will facilitate the determination of vehicle category. Laser Atlanta has recently developed two distinct types of sensors that utilize a unique multi- beam approach to detect `targets' that are potential hazards. They also provide range and range rate data to automobile control and traffic management systems.

  11. Pesticides in near-surface aquifers: An assessment using highly sensitive analytical methods and tritium

    USGS Publications Warehouse

    Kolpin, D.W.; Goolsby, D.A.; Thurman, E.M.

    1995-01-01

    In 1992, the U.S. Geological Survey (USGS) determined the distribution of pesticides in near-surface aquifers of the midwestern USA to be much more widespread than originally determined during a 1991 USGS study. The frequency of pesticide detection increased from 28.4% during the 1991 study to 59.0% during the 1992 study. This increase in pesticide detection was primarily the result of a more sensitive analytical method that used reporting limits as much as 20 times lower than previously available and a threefold increase in the number of pesticide metabolites analyzed. No pesticide concentrations exceeded the U.S. Environmental Protection Agency's (USEPAs) maximum contaminant levels or health advisory levels for drinking water. However, five of the six most frequently detected compounds during 1992 were pesticide metabolites that currently do not have drinking water standards determined. The frequent presence of pesticide metabolites for this study documents the importance of obtaining information on these compounds to understand the fate and transport of pesticides in the hydrologic system. It appears that the 56 parent compounds analyzed follow similar pathways through the hydrologic system as atrazine. When atrazine was detected by routine or sensitive analytical methods, there was an increased likelihood of detecting additional parent compounds. As expected, the frequency of pesticide detection was highly dependent on the analytical reporting limit. The number of atrazine detections more than doubled as the reporting limit decreased from 0.10 to 0.01 µg/L. The 1992 data provided no indication that the frequency of pesticide detection would level off as improved analytical methods provide concentrations below 0.003 µg/L. A relation was determined between groundwater age and the frequency of pesticide detection, with 15.8% of the samples composed of pre-1953 water and 70.3% of the samples of post-1953 water having a detection of at least one pesticide or metabolite. Pre-1953 water is less likely to contain pesticides because it tends to predate the use of pesticides to increase crop production in the Midwest. Pre-1953 water was more likely to occur in the near-surface bedrock aquifers (50.0%) than in the near-surface unconsolidated aquifers (9.1%) sampled.

  12. Design optimization of Cassegrain telescope for remote explosive trace detection

    NASA Astrophysics Data System (ADS)

    Bhavsar, Kaushalkumar; Eseller, K. E.; Prabhu, Radhakrishna

    2017-10-01

    The past three years have seen a global increase in explosive-based terror attacks. The widespread use of improvised explosives and anti-personnel landmines have caused thousands of civilian casualties across the world. Current scenario of globalized civilization threat from terror drives the need to improve the performance and capabilities of standoff explosive trace detection devices to be able to anticipate the threat from a safe distance to prevent explosions and save human lives. In recent years, laser-induced breakdown spectroscopy (LIBS) is an emerging approach for material or elemental investigations. All the principle elements on the surface are detectable in a single measurement using LIBS and hence, a standoff LIBS based method has been used to remotely detect explosive traces from several to tens of metres distance. The most important component of LIBS based standoff explosive trace detection system is the telescope which enables remote identification of chemical constituents of the explosives. However, in a compact LIBS system where Cassegrain telescope serves the purpose of laser beam delivery and light collection, need a design optimization of the telescope system. This paper reports design optimization of a Cassegrain telescope to detect explosives remotely for LIBS system. A design optimization of Schmidt corrector plate was carried out for Nd:YAG laser. Effect of different design parameters was investigated to eliminate spherical aberration in the system. Effect of different laser wavelengths on the Schmidt corrector design was also investigated for the standoff LIBS system.

  13. A Systematic Review of Wearable Systems for Cancer Detection: Current State and Challenges.

    PubMed

    Ray, Partha Pratim; Dash, Dinesh; De, Debashis

    2017-10-02

    Rapid growth of sensor and computing platforms have introduced the wearable systems. In recent years, wearable systems have led to new applications across all medical fields. The aim of this review is to present current state-of-the-art approach in the field of wearable system based cancer detection and identify key challenges that resist it from clinical adoption. A total of 472 records were screened and 11 were finally included in this study. Two types of records were studied in this context that includes 45% research articles and 55% manufactured products. The review was performed per PRISMA guidelines where considerations was given to records that were published or reported between 2009 and 2017. The identified records included 4 cancer detecting wearable systems such as breast cancer (36.3%), skin cancer (36.3%), prostate cancer (18.1%), and multi-type cancer (9%). Most works involved sensor based smart systems comprising of microcontroller, Bluetooth module, and smart phone. Few demonstrated Ultra-Wide Band (i.e. UWB) antenna based wearable systems. Skin cancer detecting wearable systems were most comprehensible ones. The current works are gradually progressing with seamless integration of sensory units along with smart networking. However, they lack in cloud computing and long-range communication paradigms. Artificial intelligence and machine learning are key ports that need to be attached with current wearable systems. Further, clinical inertia, lack of awareness, and high cost are altogether pulling back the actual growth of such system. It is well comprehended that upon sincere orientation of all identified challenges, wearable systems would emerge as vital alternative to futuristic cancer detection.

  14. Detection of Ne VIII in an Intervening Multiphase Absorption System Toward 3C 263

    NASA Astrophysics Data System (ADS)

    Narayanan, Anand; Wakker, Bart P.; Savage, Blair D.

    2009-09-01

    We report the detection of Ne VIII in an intervening multiphase absorption line system at z = 0.32566 in the Far Ultraviolet Spectroscopic Explorer spectrum of the quasar 3C 263 (zem = 0.646). The Ne VIII λ770 Å detection has a 3.9σ significance. At the same velocity, we also find absorption lines from C IV, O III, O IV, and N IV. The line parameter measurements yield log [N(Ne VIII) cm-2] = 13.98+0.10 -0.13 and b = 49.8 ± 5.5 km s-1. We find that the ionization mechanism in the gas phase giving rise to the Ne VIII absorption is inconsistent with photoionization. The absorber has a multiphase structure, with the intermediate ions produced in cool photoionized gas and the Ne VIII most likely in a warm collisionally ionized medium in the temperature range (0.5-1.0) × 106 K. This is the second ever detection of an intervening Ne VIII absorption system. Its properties resemble the previous Ne VIII absorber reported by Savage and colleagues. Direct observations of H I and O VI are needed to better constrain the physical conditions in the collisionally ionized gas phase of this absorber. Based on observations with the NASA-CNES-CSA Far Ultraviolet Spectroscopic Explorer operated by Johns Hopkins University, supported by NASA contract NAS5-32985.

  15. Confidential reporting of patient safety events in primary care: results from a multilevel classification of cognitive and system factors.

    PubMed

    Kostopoulou, Olga; Delaney, Brendan

    2007-04-01

    To classify events of actual or potential harm to primary care patients using a multilevel taxonomy of cognitive and system factors. Observational study of patient safety events obtained via a confidential but not anonymous reporting system. Reports were followed up with interviews where necessary. Events were analysed for their causes and contributing factors using causal trees and were classified using the taxonomy. Five general medical practices in the West Midlands were selected to represent a range of sizes and types of patient population. All practice staff were invited to report patient safety events. Main outcome measures were frequencies of clinical types of events reported, cognitive types of error, types of detection and contributing factors; and relationship between types of error, practice size, patient consequences and detection. 78 reports were relevant to patient safety and analysable. They included 21 (27%) adverse events and 50 (64%) near misses. 16.7% (13/71) had serious patient consequences, including one death. 75.7% (59/78) had the potential for serious patient harm. Most reports referred to administrative errors (25.6%, 20/78). 60% (47/78) of the reports contained sufficient information to characterise cognition: "situation assessment and response selection" was involved in 45% (21/47) of these reports and was often linked to serious potential consequences. The most frequent contributing factor was work organisation, identified in 71 events. This included excessive task demands (47%, 37/71) and fragmentation (28%, 22/71). Even though most reported events were near misses, events with serious patient consequences were also reported. Failures in situation assessment and response selection, a cognitive activity that occurs in both clinical and administrative tasks, was related to serious potential harm.

  16. Confidential reporting of patient safety events in primary care: results from a multilevel classification of cognitive and system factors

    PubMed Central

    Kostopoulou, Olga; Delaney, Brendan

    2007-01-01

    Objective To classify events of actual or potential harm to primary care patients using a multilevel taxonomy of cognitive and system factors. Methods Observational study of patient safety events obtained via a confidential but not anonymous reporting system. Reports were followed up with interviews where necessary. Events were analysed for their causes and contributing factors using causal trees and were classified using the taxonomy. Five general medical practices in the West Midlands were selected to represent a range of sizes and types of patient population. All practice staff were invited to report patient safety events. Main outcome measures were frequencies of clinical types of events reported, cognitive types of error, types of detection and contributing factors; and relationship between types of error, practice size, patient consequences and detection. Results 78 reports were relevant to patient safety and analysable. They included 21 (27%) adverse events and 50 (64%) near misses. 16.7% (13/71) had serious patient consequences, including one death. 75.7% (59/78) had the potential for serious patient harm. Most reports referred to administrative errors (25.6%, 20/78). 60% (47/78) of the reports contained sufficient information to characterise cognition: “situation assessment and response selection” was involved in 45% (21/47) of these reports and was often linked to serious potential consequences. The most frequent contributing factor was work organisation, identified in 71 events. This included excessive task demands (47%, 37/71) and fragmentation (28%, 22/71). Conclusions Even though most reported events were near misses, events with serious patient consequences were also reported. Failures in situation assessment and response selection, a cognitive activity that occurs in both clinical and administrative tasks, was related to serious potential harm. PMID:17403753

  17. Detection of plant quarantine pathogen Ralstonia solanacearum r3b2 with portable POCKIT™ and BLItz® systems

    USDA-ARS?s Scientific Manuscript database

    Ralstonia solanacearum (Rs) race 3 biovar 2 (r3b2) is designated as a quarantine pathogen in many countries and additionally as a Select Agent in the United States. Rapid, sensitive and accurate detection methods are urgently needed. We report here the development of two portable platforms for r3b...

  18. Detection of structural deterioration and associated airline maintenance problems

    NASA Technical Reports Server (NTRS)

    Henniker, H. D.; Mitchell, R. G.

    1972-01-01

    Airline operations involving the detection of structural deterioration and associated maintenance problems are discussed. The standard approach to the maintenance and inspection of aircraft components and systems is described. The frequency of inspections and the application of preventive maintenance practices are examined. The types of failure which airline transport aircraft encounter and the steps taken to prevent catastrophic failure are reported.

  19. High speed QPPM direct detection optical communication receivers for FSDD intersatellite links

    NASA Technical Reports Server (NTRS)

    Davidson, Frederic M.; Sun, Xiaoli

    1993-01-01

    This final report consists of four separate reports, one for each project involved in this contract. The first report is entitled '325 Mbps QPPM (quaternary pulse position modulation) Direct Detection Free Space Optical Communication Encoder and Receiver,' which was our primary work. The second report is entitled 'Test Results of the 325 Mbps QPPM High Speed Data Transmission GaAs ASICs,' which describes our work in connection with Galaxy Microsystems, Inc. who produced these ASICs for NASA. The third report, 'Receiver Performance Analysis of BPPM Optical Communication Systems Using 1.3 micron Wavelength Transmitter and InGaAs PIN Photodiodes,' was prepared at the request of the NASA/Photonics Branch for their efforts in upgrading the 1773 optical fiber data bus. The fourth report, 'Photomultiplier Tubes for Use at 1.064 micron Wavelength,' was also prepared at the request of the NASA/Photonics Branch as a research project.

  20. Molecular Thermometry

    PubMed Central

    McCabe, Kevin M.; Hernandez, Mark

    2010-01-01

    Conventional temperature measurements rely on material responses to heat, which can be detected visually. When Galileo developed an air expansion based device to detect temperature changes, Santorio, a contemporary physician, added a scale to create the first thermometer. With this instrument, patients’ temperatures could be measured, recorded and related to changing health conditions. Today, advances in materials science and bioengineering provide new ways to report temperature at the molecular level in real time. In this review the scientific foundations and history of thermometry underpin a discussion of the discoveries emerging from the field of molecular thermometry. Intracellular nanogels and heat sensing biomolecules have been shown to accurately report temperature changes at the nano-scale. Various systems will soon provide the ability to accurately measure temperature changes at the tissue, cellular, and even sub-cellular level, allowing for detection and monitoring of very small changes in local temperature. In the clinic this will lead to enhanced detection of tumors and localized infection, and accurate and precise monitoring of hyperthermia based therapies. Some nanomaterial systems have even demonstrated a theranostic capacity for heat-sensitive, local delivery of chemotherapeutics. Just as early thermometry moved into the clinic, so too will these molecular thermometers. PMID:20139796

  1. Serologic test development. Progress report, July 1, 1974--June 30, 1975. [Radioimmunoassay method for diagnosis of swine and bovine diseases

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Saunders, G.C.; Clinard, E.H.; Sanders, W.M.

    1975-01-01

    The Enzyme-Labeled Antibody (ELA) test system has been adapted to microtiter trays for both cell bound and soluble antigens. Problems involving both readout instrumentation and reaction product stability have been solved. Progress involving application of the ELA system for detection of hog cholera, trichinosis, swine brucellosis, and swine and bovine tuberculosis is reported. Prototype instrumentation for automating ELA processing is being developed. (auth)

  2. Vehicle Integrated Prognostic Reasoner (VIPR) Final Report

    NASA Technical Reports Server (NTRS)

    Bharadwaj, Raj; Mylaraswamy, Dinkar; Cornhill, Dennis; Biswas, Gautam; Koutsoukos, Xenofon; Mack, Daniel

    2013-01-01

    A systems view is necessary to detect, diagnose, predict, and mitigate adverse events during the flight of an aircraft. While most aircraft subsystems look for simple threshold exceedances and report them to a central maintenance computer, the vehicle integrated prognostic reasoner (VIPR) proactively generates evidence and takes an active role in aircraft-level health assessment. Establishing the technical feasibility and a design trade-space for this next-generation vehicle-level reasoning system (VLRS) is the focus of our work.

  3. A nano grating tunable MEMS optical filter for high-speed on-chip multispectral fluorescent detection.

    PubMed

    Truxal, Steven C; Huang, Nien-Tsu; Kurabayashi, Katsuo

    2009-01-01

    We report a microelectromechanical (MEMS) tunable optical filter and its integration in a fluorescence microscope for high speed on-chip spectral measurements. This integration allows for measurements of any fluorescence sample placed onto the microscope stage. We demonstrate the system capabilities by taking spectral measurements of multicolor fluorescent beads and fluorescently labeled cells passing through a microfluidic cytometer. The system has applications in biological studies where the measurement of multiple fluorescent peaks is restricted by the detection method's speed and sensitivity.

  4. Optical Amplification of Spin Noise Spectroscopy via Homodyne Detection

    NASA Astrophysics Data System (ADS)

    Sterin, Pavel; Wiegand, Julia; Hübner, Jens; Oestreich, Michael

    2018-03-01

    Spin noise (SN) spectroscopy measurements on delicate semiconductor spin systems, like single (In,Ga)As quantum dots, are currently not limited by optical shot noise but rather by the electronic noise of the detection system. We report on a realization of homodyne SN spectroscopy enabling shot-noise-limited SN measurements. The proof-of-principle measurements on impurities in an isotopically enriched rubidium atom vapor show that homodyne SN spectroscopy can be utilized even in the low-frequency spectrum, which facilitates advanced semiconductor spin research like higher order SN measurements on spin qubits.

  5. Kepler Detects Planet Orbiting Two Stars (Kepler-16b) Reporter Package for TWAN

    NASA Image and Video Library

    2011-09-19

    NASA's Kepler Mission has made the first detection of a planet orbiting two stars. About 200 light years away from our solar system, the planet Kepler-16b is cold, gaseous and about the size of Saturn. Its stars are both smaller than the Sun and about 2 billion years younger than our Solar System. They orbit around each other, so from our vantage point they take turns eclipsing each other about every 41 days. The planet Kepler-16b orbits around both stars every 229 days.

  6. Reporter Proteins in Whole-Cell Optical Bioreporter Detection Systems, Biosensor Integrations, and Biosensing Applications

    PubMed Central

    Close, Dan M.; Ripp, Steven; Sayler, Gary S.

    2009-01-01

    Whole-cell, genetically modified bioreporters are designed to emit detectable signals in response to a target analyte or related group of analytes. When integrated with a transducer capable of measuring those signals, a biosensor results that acts as a self-contained analytical system useful in basic and applied environmental, medical, pharmacological, and agricultural sciences. Historically, these devices have focused on signaling proteins such as green fluorescent protein, aequorin, firefly luciferase, and/or bacterial luciferase. The biochemistry and genetic development of these sensor systems as well as the advantages, challenges, and common applications of each one will be discussed. PMID:22291559

  7. A visual surveillance system for person re-identification

    NASA Astrophysics Data System (ADS)

    El-Alfy, Hazem; Muramatsu, Daigo; Teranishi, Yuuichi; Nishinaga, Nozomu; Makihara, Yasushi; Yagi, Yasushi

    2017-03-01

    We attempt the problem of autonomous surveillance for person re-identification. This is an active research area, where most recent work focuses on the open challenges of re-identification, independently of prerequisites of detection and tracking. In this paper, we are interested in designing a complete surveillance system, joining all the pieces of the puzzle together. We start by collecting our own dataset from multiple cameras. Then, we automate the process of detection and tracking of human subjects in the scenes, followed by performing the re-identification task. We evaluate the recognition performance of our system, report its strengths, discuss open challenges and suggest ways to address them.

  8. A quantification of the effectiveness of EPID dosimetry and software-based plan verification systems in detecting incidents in radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bojechko, Casey; Phillps, Mark; Kalet, Alan

    Purpose: Complex treatments in radiation therapy require robust verification in order to prevent errors that can adversely affect the patient. For this purpose, the authors estimate the effectiveness of detecting errors with a “defense in depth” system composed of electronic portal imaging device (EPID) based dosimetry and a software-based system composed of rules-based and Bayesian network verifications. Methods: The authors analyzed incidents with a high potential severity score, scored as a 3 or 4 on a 4 point scale, recorded in an in-house voluntary incident reporting system, collected from February 2012 to August 2014. The incidents were categorized into differentmore » failure modes. The detectability, defined as the number of incidents that are detectable divided total number of incidents, was calculated for each failure mode. Results: In total, 343 incidents were used in this study. Of the incidents 67% were related to photon external beam therapy (EBRT). The majority of the EBRT incidents were related to patient positioning and only a small number of these could be detected by EPID dosimetry when performed prior to treatment (6%). A large fraction could be detected by in vivo dosimetry performed during the first fraction (74%). Rules-based and Bayesian network verifications were found to be complimentary to EPID dosimetry, able to detect errors related to patient prescriptions and documentation, and errors unrelated to photon EBRT. Combining all of the verification steps together, 91% of all EBRT incidents could be detected. Conclusions: This study shows that the defense in depth system is potentially able to detect a large majority of incidents. The most effective EPID-based dosimetry verification is in vivo measurements during the first fraction and is complemented by rules-based and Bayesian network plan checking.« less

  9. Transcriptional regulatory proteins as biosensing tools.

    PubMed

    Turner, Kendrick; Joel, Smita; Feliciano, Jessika; Feltus, Agatha; Pasini, Patrizia; Wynn, Daniel; Dau, Peter; Dikici, Emre; Deo, Sapna K; Daunert, Sylvia

    2017-06-22

    We have developed sensing systems employing different classes of transcriptional regulatory proteins genetically and chemically modified to incorporate a fluorescent reporter molecule for detection of arsenic, hydroxylated polychlorinated biphenyls (OH-PCBs), and cyclic AMP (cAMP). These are the first examples of optical sensing systems based on transcriptional regulatory proteins.

  10. Security of Data, Stored in Information Systems of Bulgarian Municipal Administrations

    NASA Astrophysics Data System (ADS)

    Kapralyakov, Petko

    2011-12-01

    Massive influx of information technology in municipal administrations increases their efficiency in delivering public services but increased the risk of theft of confidential information electronically. The report proposed an approach for improving information security for small municipal governments in Bulgaria through enhanced intrusion detection and prevention system.

  11. Real Time Network Monitoring and Reporting System

    ERIC Educational Resources Information Center

    Massengale, Ricky L., Sr.

    2009-01-01

    With the ability of modern system developers to develop intelligent programs that allows machines to learn, modify and evolve themselves, current trends of reactionary methods to detect and eradicate malicious software code from infected machines is proving to be too costly. Addressing malicious software after an attack is the current methodology…

  12. Gold Nanorod-based Photo-PCR System for One-Step, Rapid Detection of Bacteria

    PubMed Central

    Kim, Jinjoo; Kim, Hansol; Park, Ji Ho; Jon, Sangyong

    2017-01-01

    The polymerase chain reaction (PCR) has been an essential tool for diagnosis of infectious diseases, but conventional PCR still has some limitations with respect to applications to point-of-care (POC) diagnostic systems that require rapid detection and miniaturization. Here we report a light-based PCR method, termed as photo-PCR, which enables rapid detection of bacteria in a single step. In the photo-PCR system, poly(enthylene glycol)-modified gold nanorods (PEG-GNRs), used as a heat generator, are added into the PCR mixture, which is subsequently periodically irradiated with a 808-nm laser to create thermal cycling. Photo-PCR was able to significantly reduce overall thermal cycling time by integrating bacterial cell lysis and DNA amplification into a single step. Furthermore, when combined with KAPA2G fast polymerase and cooling system, the entire process of bacterial genomic DNA extraction and amplification was further shortened, highlighting the potential of photo-PCR for use in a portable, POC diagnostic system. PMID:29071186

  13. Classification of Small Negative Lightning Reports at the KSC-ER

    NASA Technical Reports Server (NTRS)

    Ward, Jennifer G.; Cummins, Kenneth L.; Krider, Philip

    2008-01-01

    The NASA Kennedy Space Center (KSC) and Air Force Eastern Range (ER) operate an extensive suite of lightning sensors because Florida experiences the highest area density of ground strikes in the United States, with area densities approaching 16 fl/sq km/yr when accumulated in 10x10 km (100 sq km) grids. The KSC-ER use data derived from two cloud-to-ground (CG) lightning detection networks, the "Cloud-to-Ground Lightning Surveillance System" (CGLSS) and the U.S. National Lightning Detection Network (TradeMark) (NLDN) plus a 3-dimensional lightning mapping system, the Lightning Detection and Ranging (LDAR) system, to provide warnings for ground operations and to insure mission safety during space launches. For operational applications at the KSC-ER it is important to understand the performance of each lightning detection system in considerable detail. In this work we examine a specific subset of the CGLSS stroke reports that have low values of the negative inferred peak current, Ip, i.e. values between 0 and -7 kA, and were thought to produce a new ground contact (NGC). When possible, the NLDN and LDAR systems were used to validate the CGLSS classification and to determine how many of these reported strokes were first strokes, subsequent strokes in a pre-existing channel (PEC), or cloud pulses that the CGLSS misclassified as CG strokes. It is scientifically important to determine the smallest current that can reach the ground either in the form of a first stroke or by way of a subsequent stroke that creates a new ground contact. In Biagi et al (2007), 52 low amplitude, negative return strokes ([Ip] < or = 10 kA) were evaluated in southern Arizona, northern Texas, and southern Oklahoma. The authors found that 50-87% of the small NLDN reports could be classified as CG (either first or subsequent strokes) on the basis of video and waveform recordings. Low amplitude return strokes are interesting because they are usually difficult to detect, and they are thought to bypass conventional lightning protection that relies on a sufficient attractive radius to prevent "shielding failure" (Golde, 1977). They also have larger location errors compared to the larger current events. In this study, we use the estimated peak current provided by the CGLSS and the results of our classification to determine the minimum Ip for each category of CG stroke and its probability of occurrence. Where possible, these results are compared to the findings in the literature.

  14. Characterization of Adverse Events Detected in a Large Health Care Delivery System Using an Enhanced Global Trigger Tool over a Five-Year Interval

    PubMed Central

    Kennerly, Donald A; Kudyakov, Rustam; da Graca, Briget; Saldaña, Margaret; Compton, Jan; Nicewander, David; Gilder, Richard

    2014-01-01

    Objective To report 5 years of adverse events (AEs) identified using an enhanced Global Trigger Tool (GTT) in a large health care system. Study Setting Records from monthly random samples of adults admitted to eight acute care hospitals from 2007 to 2011 with lengths of stay ≥3 days were reviewed. Study Design We examined AE incidence overall and by presence on admission, severity, stemming from care provided versus omitted, preventability, and category; and the overlap with commonly used AE-detection systems. Data Collection Professional nurse reviewers abstracted 9,017 records using the enhanced GTT, recording triggers and AEs. Medical record/account numbers were matched to identify overlapping voluntary reports or AHRQ Patient Safety Indicators (PSIs). Principal Findings Estimated AE rates were as follows: 61.4 AEs/1,000 patient-days, 38.1 AEs/100 discharges, and 32.1 percent of patients with ≥1 AE. Of 1,300 present-on-admission AEs (37.9 percent of total), 78.5 percent showed NCC-MERP level F harm and 87.6 percent were “preventable/possibly preventable.” Of 2,129 hospital-acquired AEs, 63.3 percent had level E harm, 70.8 percent were “preventable/possibly preventable”; the most common category was “surgical/procedural” (40.5 percent). Voluntary reports and PSIs captured <5 percent of encounters with hospital-acquired AEs. Conclusions AEs are common and potentially amenable to prevention. GTT-identified AEs are seldom caught by commonly used AE-detection systems. PMID:24628436

  15. Automatic polymerase chain reaction product detection system for food safety monitoring using zinc finger protein fused to luciferase.

    PubMed

    Yoshida, Wataru; Kezuka, Aki; Murakami, Yoshiyuki; Lee, Jinhee; Abe, Koichi; Motoki, Hiroaki; Matsuo, Takafumi; Shimura, Nobuaki; Noda, Mamoru; Igimi, Shizunobu; Ikebukuro, Kazunori

    2013-11-01

    An automatic polymerase chain reaction (PCR) product detection system for food safety monitoring using zinc finger (ZF) protein fused to luciferase was developed. ZF protein fused to luciferase specifically binds to target double stranded DNA sequence and has luciferase enzymatic activity. Therefore, PCR products that comprise ZF protein recognition sequence can be detected by measuring the luciferase activity of the fusion protein. We previously reported that PCR products from Legionella pneumophila and Escherichia coli (E. coli) O157 genomic DNA were detected by Zif268, a natural ZF protein, fused to luciferase. In this study, Zif268-luciferase was applied to detect the presence of Salmonella and coliforms. Moreover, an artificial zinc finger protein (B2) fused to luciferase was constructed for a Norovirus detection system. In the luciferase activity detection assay, several bound/free separation process is required. Therefore, an analyzer that automatically performed the bound/free separation process was developed to detect PCR products using the ZF-luciferase fusion protein. By means of the automatic analyzer with ZF-luciferase fusion protein, target pathogenic genomes were specifically detected in the presence of other pathogenic genomes. Moreover, we succeeded in the detection of 10 copies of E. coli BL21 without extraction of genomic DNA by the automatic analyzer and E. coli was detected with a logarithmic dependency in the range of 1.0×10 to 1.0×10(6) copies. Copyright © 2013 Elsevier B.V. All rights reserved.

  16. Automatic nipple detection on 3D images of an automated breast ultrasound system (ABUS)

    NASA Astrophysics Data System (ADS)

    Javanshir Moghaddam, Mandana; Tan, Tao; Karssemeijer, Nico; Platel, Bram

    2014-03-01

    Recent studies have demonstrated that applying Automated Breast Ultrasound in addition to mammography in women with dense breasts can lead to additional detection of small, early stage breast cancers which are occult in corresponding mammograms. In this paper, we proposed a fully automatic method for detecting the nipple location in 3D ultrasound breast images acquired from Automated Breast Ultrasound Systems. The nipple location is a valuable landmark to report the position of possible abnormalities in a breast or to guide image registration. To detect the nipple location, all images were normalized. Subsequently, features have been extracted in a multi scale approach and classification experiments were performed using a gentle boost classifier to identify the nipple location. The method was applied on a dataset of 100 patients with 294 different 3D ultrasound views from Siemens and U-systems acquisition systems. Our database is a representative sample of cases obtained in clinical practice by four medical centers. The automatic method could accurately locate the nipple in 90% of AP (Anterior-Posterior) views and in 79% of the other views.

  17. Light emitting diode, photodiode-based fluorescence detection system for DNA analysis with microchip electrophoresis.

    PubMed

    Hall, Gordon H; Glerum, D Moira; Backhouse, Christopher J

    2016-02-01

    Electrophoretic separation of fluorescently end-labeled DNA after a PCR serves as a gold standard in genetic diagnostics. Because of their size and cost, instruments for this type of analysis have had limited market uptake, particularly for point-of-care applications. This might be changed through a higher level of system integration and lower instrument costs that can be realized through the use of LEDs for excitation and photodiodes for detection--if they provide sufficient sensitivity. Here, we demonstrate an optimized microchip electrophoresis instrument using polymeric fluidic chips with fluorescence detection of end-labeled DNA with a LOD of 0.15 nM of Alexa Fluor 532. This represents orders of magnitude improvement over previously reported instruments of this type. We demonstrate the system with an electrophoretic separation of two PCR products and their respective primers. We believe that this is the first LED-induced fluorescence microchip electrophoresis system with photodiode-based detection that could be used for standard applications of PCR and electrophoresis. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Microsphere integrated microfluidic disk: synergy of two techniques for rapid and ultrasensitive dengue detection.

    PubMed

    Hosseini, Samira; Aeinehvand, Mohammad M; Uddin, Shah M; Benzina, Abderazak; Rothan, Hussin A; Yusof, Rohana; Koole, Leo H; Madou, Marc J; Djordjevic, Ivan; Ibrahim, Fatimah

    2015-11-09

    The application of microfluidic devices in diagnostic systems is well-established in contemporary research. Large specific surface area of microspheres, on the other hand, has secured an important position for their use in bioanalytical assays. Herein, we report a combination of microspheres and microfluidic disk in a unique hybrid platform for highly sensitive and selective detection of dengue virus. Surface engineered polymethacrylate microspheres with carefully designed functional groups facilitate biorecognition in a multitude manner. In order to maximize the utility of the microspheres' specific surface area in biomolecular interaction, the microfluidic disk was equipped with a micromixing system. The mixing mechanism (microballoon mixing) enhances the number of molecular encounters between spheres and target analyte by accessing the entire sample volume more effectively, which subsequently results in signal amplification. Significant reduction of incubation time along with considerable lower detection limits were the prime motivations for the integration of microspheres inside the microfluidic disk. Lengthy incubations of routine analytical assays were reduced from 2 hours to 5 minutes while developed system successfully detected a few units of dengue virus. Obtained results make this hybrid microsphere-microfluidic approach to dengue detection a promising avenue for early detection of this fatal illness.

  19. Remote laser drilling and sampling system for the detection of concealed explosives

    NASA Astrophysics Data System (ADS)

    Wild, D.; Pschyklenk, L.; Theiß, C.; Holl, G.

    2017-05-01

    The detection of hazardous materials like explosives is a central issue in national security in the field of counterterrorism. One major task includes the development of new methods and sensor systems for the detection. Many existing remote or standoff methods like infrared or raman spectroscopy find their limits, if the hazardous material is concealed in an object. Imaging technologies using x-ray or terahertz radiation usually yield no information about the chemical content itself. However, the exact knowledge of the real threat potential of a suspicious object is crucial for disarming the device. A new approach deals with a laser drilling and sampling system for the use as verification detector for suspicious objects. Central part of the system is a miniaturised, diode pumped Nd:YAG laser oscillator-amplifier. The system allows drilling into most materials like metals, synthetics or textiles with bore hole diameters in the micron scale. During the drilling process, the hazardous material can be sampled for further investigation with suitable detection methods. In the reported work, laser induced breakdown spectroscopy (LIBS) is used to monitor the drilling process and to classify the drilled material. Also experiments were carried out to show the system's ability to not ignite even sensitive explosives like triacetone triperoxide (TATP). The detection of concealed hazardous material is shown for different explosives using liquid chromatography and ion mobility spectrometry.

  20. "In Vitro" Synthesis and Activity of Reporter Proteins in an "Escherichia coli" S30 Extract System: An Undergraduate Experiment

    ERIC Educational Resources Information Center

    Higgins, Pamela J.

    2005-01-01

    This undergraduate laboratory experiment integrates multiple techniques ("in vitro" synthesis, enzyme assays, Western blotting) to determine the production and detection sensitivity of two common reporter proteins (beta-galactosidase and luciferase) within an "Escherichia coli" S30 transcription/translation extract. Comparison of the data suggests…

  1. State of the art evaluation of traffic detection and monitoring systems. Volume 1, Phases A & B : design [Final report

    DOT National Transportation Integrated Search

    2007-10-01

    This report covers the Phase A and B activities of Research Project SPR 627 for the Arizona Department of Transportation (ADOT). Phase C is planned as a separate research activity and is anticipated to begin in the near term, following the completion...

  2. 40 CFR 63.1018 - Reporting requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 10 2010-07-01 2010-07-01 false Reporting requirements. 63.1018... requirements of § 63.1007, excluding those pumps designated for no detectable emissions under the provisions of § 63.1007(e)(2) and those pumps complying with the closed vent system provisions of § 63.1007(e)(3...

  3. A Multilevel Secure Constrained Intrusion Detection System Prototype

    DTIC Science & Technology

    2010-12-01

    information is estimated to average 1 hour per response, including the time for reviewing instruction, searching existing data sources, gathering and...Reduction Project (0704-0188) Washington DC 20503. 1 . AGENCY USE ONLY (Leave blank) 2. REPORT DATE December 2010 3. REPORT TYPE AND DATES COVERED... 1 A. MOTIVATION....................................................................................... 1 B. PURPOSE OF STUDY

  4. Information about ADRs explored by pharmacovigilance approaches: a qualitative review of studies on antibiotics, SSRIs and NSAIDs

    PubMed Central

    Aagaard, Lise; Hansen, Ebba Holme

    2009-01-01

    Background Despite surveillance efforts, unexpected and serious adverse drug reactions (ADRs) repeatedly occur after marketing. The aim of this article is to analyse ADRs reported by available ADR signal detection approaches and to explore which information about new and unexpected ADRs these approaches have detected. Methods We selected three therapeutic cases for the review: antibiotics for systemic use, non-steroidal anti-inflammatory medicines (NSAID) and selective serotonin re-uptake inhibitors (SSRI). These groups are widely used and represent different therapeutic classes of medicines. The ADR studies were identified through literature search in Medline and Embase. The search was conducted in July 2007. For each therapeutic case, we analysed the time of publication, the strengths of the evidence of safety in the different approaches, reported ADRs and whether the studies have produced new information about ADRs compared to the information available at the time of marketing. Results 79 studies were eligible for inclusion in the analysis: 23 antibiotics studies, 35 NSAID studies, 20 SSRI studies. Studies were mainly published from the end of the 1990s and onwards. Although the drugs were launched in different decades, both analytical and observational approaches to ADR studies were similar for all three therapeutic cases: antibiotics, NSAIDs and SSRIs. The studies primarily dealt with analyses of ADRs of the type A and B and to a lesser extent C and D, cf. Rawlins' classification system. The therapeutic cases provided similar results with regard to detecting information about new ADRs despite different time periods and organs attacked. Approaches ranging higher in the evidence hierarchy provided information about risks of already known or expected ADRs, while information about new and previously unknown ADRs was only detected by case reports, the lowest ranking approach in the evidence hierarchy. Conclusion Although the medicines were launched in different decades, approaches to the ADR studies were similar for all three therapeutic cases: antibiotics, NSAIDs and SSRIs. Both descriptive and analytical designs were applied. Despite the fact that analytical studies rank higher in the evidence hierarchy, only the lower ranking descriptive case reports/spontaneous reports provided information about new and previously undetected ADRs. This review underscores the importance of systems for spontaneous reporting of ADRs. Therefore, spontaneous reporting should be encouraged further and the information in ADR databases should continuously be subjected to systematic analysis. PMID:19254390

  5. Information about ADRs explored by pharmacovigilance approaches: a qualitative review of studies on antibiotics, SSRIs and NSAIDs.

    PubMed

    Aagaard, Lise; Hansen, Ebba Holme

    2009-03-03

    Despite surveillance efforts, unexpected and serious adverse drug reactions (ADRs) repeatedly occur after marketing. The aim of this article is to analyse ADRs reported by available ADR signal detection approaches and to explore which information about new and unexpected ADRs these approaches have detected. We selected three therapeutic cases for the review: antibiotics for systemic use, non-steroidal anti-inflammatory medicines (NSAID) and selective serotonin re-uptake inhibitors (SSRI). These groups are widely used and represent different therapeutic classes of medicines. The ADR studies were identified through literature search in Medline and Embase. The search was conducted in July 2007. For each therapeutic case, we analysed the time of publication, the strengths of the evidence of safety in the different approaches, reported ADRs and whether the studies have produced new information about ADRs compared to the information available at the time of marketing. 79 studies were eligible for inclusion in the analysis: 23 antibiotics studies, 35 NSAID studies, 20 SSRI studies. Studies were mainly published from the end of the 1990s and onwards. Although the drugs were launched in different decades, both analytical and observational approaches to ADR studies were similar for all three therapeutic cases: antibiotics, NSAIDs and SSRIs. The studies primarily dealt with analyses of ADRs of the type A and B and to a lesser extent C and D, cf. Rawlins' classification system. The therapeutic cases provided similar results with regard to detecting information about new ADRs despite different time periods and organs attacked. Approaches ranging higher in the evidence hierarchy provided information about risks of already known or expected ADRs, while information about new and previously unknown ADRs was only detected by case reports, the lowest ranking approach in the evidence hierarchy. Although the medicines were launched in different decades, approaches to the ADR studies were similar for all three therapeutic cases: antibiotics, NSAIDs and SSRIs. Both descriptive and analytical designs were applied. Despite the fact that analytical studies rank higher in the evidence hierarchy, only the lower ranking descriptive case reports/spontaneous reports provided information about new and previously undetected ADRs. This review underscores the importance of systems for spontaneous reporting of ADRs. Therefore, spontaneous reporting should be encouraged further and the information in ADR databases should continuously be subjected to systematic analysis.

  6. 50 CFR 18.128 - What are the mitigation, monitoring, and reporting requirements?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ..., DEPARTMENT OF THE INTERIOR (CONTINUED) TAKING, POSSESSION, TRANSPORTATION, SALE, PURCHASE, BARTER... early detection system in regards to proximate bear activity to Industry facilities. (4) Offshore sites...

  7. A ligation-triggered DNAzyme cascade for amplified fluorescence detection of biological small molecules with zero-background signal.

    PubMed

    Lu, Li-Min; Zhang, Xiao-Bing; Kong, Rong-Mei; Yang, Bin; Tan, Weihong

    2011-08-03

    Many types of fluorescent sensing systems have been reported for biological small molecules. Particularly, several methods have been developed for the recognition of ATP or NAD(+), but they only show moderate sensitivity, and they cannot discriminate either ATP or NAD(+) from their respective analogues. We have addressed these limitations and report here a dual strategy which combines split DNAzyme-based background reduction with catalytic and molecular beacon (CAMB)-based amplified detection to develop a ligation-triggered DNAzyme cascade, resulting in ultrahigh sensitivity. First, the 8-17 DNAzyme is split into two separate oligonucleotide fragments as the building blocks for the DNA ligation reaction, thereby providing a zero-background signal to improve overall sensitivity. Next, a CAMB strategy is further employed for amplified signal detection achieved through cycling and regenerating the DNAzyme to realize the true enzymatic multiple turnover (one enzyme catalyzes the cleavage of several substrates) of catalytic beacons. This combination of zero-background signal and signal amplification significantly improves the sensitivity of the sensing systems, resulting in detection limits of 100 and 50 pM for ATP and NAD(+), respectively, much lower than those of previously reported biosensors. Moreover, by taking advantage of the highly specific biomolecule-dependence of the DNA ligation reaction, the developed DNAzyme cascades show significantly high selectivity toward the target cofactor (ATP or NAD(+)), and the target biological small molecule can be distinguished from its analogues. Therefore, as a new and universal platform for the design of DNA ligation reaction-based sensing systems, this novel ligation-triggered DNAzyme cascade method may find a broad spectrum of applications in both environmental and biomedical fields.

  8. Laboratory-Based Prospective Surveillance for Community Outbreaks of Shigella spp. in Argentina

    PubMed Central

    Viñas, María R.; Tuduri, Ezequiel; Galar, Alicia; Yih, Katherine; Pichel, Mariana; Stelling, John; Brengi, Silvina P.; Della Gaspera, Anabella; van der Ploeg, Claudia; Bruno, Susana; Rogé, Ariel; Caffer, María I.; Kulldorff, Martin; Galas, Marcelo

    2013-01-01

    Background To implement effective control measures, timely outbreak detection is essential. Shigella is the most common cause of bacterial diarrhea in Argentina. Highly resistant clones of Shigella have emerged, and outbreaks have been recognized in closed settings and in whole communities. We hereby report our experience with an evolving, integrated, laboratory-based, near real-time surveillance system operating in six contiguous provinces of Argentina during April 2009 to March 2012. Methodology To detect localized shigellosis outbreaks timely, we used the prospective space-time permutation scan statistic algorithm of SaTScan, embedded in WHONET software. Twenty three laboratories sent updated Shigella data on a weekly basis to the National Reference Laboratory. Cluster detection analysis was performed at several taxonomic levels: for all Shigella spp., for serotypes within species and for antimicrobial resistance phenotypes within species. Shigella isolates associated with statistically significant signals (clusters in time/space with recurrence interval ≥365 days) were subtyped by pulsed field gel electrophoresis (PFGE) using PulseNet protocols. Principal Findings In three years of active surveillance, our system detected 32 statistically significant events, 26 of them identified before hospital staff was aware of any unexpected increase in the number of Shigella isolates. Twenty-six signals were investigated by PFGE, which confirmed a close relationship among the isolates for 22 events (84.6%). Seven events were investigated epidemiologically, which revealed links among the patients. Seventeen events were found at the resistance profile level. The system detected events of public health importance: infrequent resistance profiles, long-lasting and/or re-emergent clusters and events important for their duration or size, which were reported to local public health authorities. Conclusions/Significance The WHONET-SaTScan system may serve as a model for surveillance and can be applied to other pathogens, implemented by other networks, and scaled up to national and international levels for early detection and control of outbreaks. PMID:24349586

  9. Laboratory-based prospective surveillance for community outbreaks of Shigella spp. in Argentina.

    PubMed

    Viñas, María R; Tuduri, Ezequiel; Galar, Alicia; Yih, Katherine; Pichel, Mariana; Stelling, John; Brengi, Silvina P; Della Gaspera, Anabella; van der Ploeg, Claudia; Bruno, Susana; Rogé, Ariel; Caffer, María I; Kulldorff, Martin; Galas, Marcelo

    2013-01-01

    To implement effective control measures, timely outbreak detection is essential. Shigella is the most common cause of bacterial diarrhea in Argentina. Highly resistant clones of Shigella have emerged, and outbreaks have been recognized in closed settings and in whole communities. We hereby report our experience with an evolving, integrated, laboratory-based, near real-time surveillance system operating in six contiguous provinces of Argentina during April 2009 to March 2012. To detect localized shigellosis outbreaks timely, we used the prospective space-time permutation scan statistic algorithm of SaTScan, embedded in WHONET software. Twenty three laboratories sent updated Shigella data on a weekly basis to the National Reference Laboratory. Cluster detection analysis was performed at several taxonomic levels: for all Shigella spp., for serotypes within species and for antimicrobial resistance phenotypes within species. Shigella isolates associated with statistically significant signals (clusters in time/space with recurrence interval ≥365 days) were subtyped by pulsed field gel electrophoresis (PFGE) using PulseNet protocols. In three years of active surveillance, our system detected 32 statistically significant events, 26 of them identified before hospital staff was aware of any unexpected increase in the number of Shigella isolates. Twenty-six signals were investigated by PFGE, which confirmed a close relationship among the isolates for 22 events (84.6%). Seven events were investigated epidemiologically, which revealed links among the patients. Seventeen events were found at the resistance profile level. The system detected events of public health importance: infrequent resistance profiles, long-lasting and/or re-emergent clusters and events important for their duration or size, which were reported to local public health authorities. The WHONET-SaTScan system may serve as a model for surveillance and can be applied to other pathogens, implemented by other networks, and scaled up to national and international levels for early detection and control of outbreaks.

  10. Synthesis of a multi-functional DNA nanosphere barcode system for direct cell detection.

    PubMed

    Han, Sangwoo; Lee, Jae Sung; Lee, Jong Bum

    2017-09-28

    Nucleic acid-based technologies have been applied to numerous biomedical applications. As a novel material for target detection, DNA has been used to construct a barcode system with a range of structures. This paper reports multi-functionalized DNA nanospheres (DNANSs) by rolling circle amplification (RCA) with several functionalized nucleotides. DNANSs with a barcode system were designed to exhibit fluorescence for coding enhanced signals and contain biotin for more functionalities, including targeting through the biotin-streptavidin (biotin-STA) interaction. Functionalized deoxynucleotide triphosphates (dNTPs) were mixed in the RCA process and functional moieties can be expressed on the DNANSs. The anti-epidermal growth factor receptor antibodies (anti-EGFR Abs) can be conjugated on DNANSs for targeting cancer cells specifically. As a proof of concept, the potential of the multi-functional DNANS barcode was demonstrated by direct cell detection as a simple detection method. The DNANS barcode provides a new route for the simple and rapid selective recognition of cancer cells.

  11. Demonstration of motionless Knudsen pump based micro-gas chromatography featuring micro-fabricated columns and on-column detectors.

    PubMed

    Liu, Jing; Gupta, Naveen K; Wise, Kensall D; Gianchandani, Yogesh B; Fan, Xudong

    2011-10-21

    This paper reports the investigation of a micro-gas chromatography (μGC) system that utilizes an array of miniaturized motionless Knudsen pumps (KPs) as well as microfabricated separation columns and optical detectors. A prototype system was built to achieve a flow rate of 1 mL min(-1) and 0.26 mL min(-1) for helium and dry air, respectively, when they were used as carrier gas. This system was then employed to evaluate GC performance compromises and demonstrate the ability to separate and detect gas mixtures containing analytes of different volatilities and polarities. Furthermore, the use of pressure programming of the KP array was demonstrated to significantly shorten the analysis time while maintaining a high detection resolution. Using this method, we obtained a high resolution detection of 5 alkanes of different volatilities within 5 min. Finally, we successfully detected gas mixtures of various polarities using a tandem-column μGC configuration by installing two on-column optical detectors to obtain complementary chromatograms.

  12. Continuous, Real-Time Monitoring of Cocaine in Undiluted Blood Serum via a Microfluidic, Electrochemical Aptamer-Based Sensor

    PubMed Central

    Swensen, James S.; Xiao, Yi; Ferguson, Brian S.; Lubin, Arica A.; Lai, Rebecca Y.; Heeger, Alan J.; Plaxco, Kevin W.; Soh, H. Tom.

    2009-01-01

    The development of a biosensor system capable of continuous, real-time measurement of small-molecule analytes directly in complex, unprocessed aqueous samples has been a significant challenge, and successful implementation has been achieved for only a limited number of targets. Towards a general solution to this problem, we report here the Microfluidic Electrochemical Aptamer-based Sensor (MECAS) chip wherein we integrate target-specific DNA aptamers that fold, and thus generate an electrochemical signal, in response to the analyte with a microfluidic detection system. As a model, we demonstrate the continuous, real-time (~1 minute time resolution) detection of the small molecule drug cocaine at near physiological, low micromolar concentrations directly in undiluted, otherwise unmodified blood serum. We believe our approach of integrating folding-based electrochemical sensors with miniaturized detection systems may lay the ground work for the real-time, point-of-care detection of a wide variety of molecular targets. PMID:19271708

  13. Water vapour emission in vegetable fuel: absorption cell measurements and detection limits of our CO II Dial system

    NASA Astrophysics Data System (ADS)

    Bellecci, C.; De Leo, L.; Gaudio, P.; Gelfusa, M.; Lo Feudo, T.; Martellucci, S.; Richetta, M.

    2006-09-01

    Forest fires can be the cause of serious environmental and economic damages. For this reason a considerable effort has been directed toward the forest protection and fire fighting. In the early forest fire detection, Lidar technique present considerable advantages compared to the passive detection methods based on infrared cameras currently in common use, due its higher sensitivity and ability to accurately locate the fire. The combustion phase of the vegetable matter causes a great amount of water vapour emission, thus the water molecule behaviour will be studied to obtain a fire detection system ready and efficient also before the flame propagation. A first evaluation of increment of the water vapour concentration compared to standard one will be estimated by a numerical simulation. These results will be compared with the experimental measurements carried out into a cell with a CO II Dial system, burning different kinds of vegetable fuel. Our results and their comparison will be reported in this paper.

  14. Detection of Illicit Drugs with the EURITRACK System

    NASA Astrophysics Data System (ADS)

    Perot, B.; Carasco, C.; Valkovic, V.; Sudac, D.; Franulovic, A.

    2009-03-01

    The EURopean Illicit TRAfficking Countermeasures Kit (EURITRACK) inspection system has been developed within the 6th EU Framework Program to complement X-ray scanners in the detection of explosives and other illicit materials hidden in cargo containers. Gamma rays are produced inside the cargo materials by 14 MeV tagged neutron beams, which yields information about the chemical composition of the transported goods. In the beginning of year 2007, the EURITRACK system was implemented in the Seaport of Rijeka, Croatia, primarily to carry out a demonstration using real containers to conduct a series of detection tests. This article reports tests performed with real samples of illicit drugs hidden in a metallic cargo with an average density of 0.2 g/cm3. Heroin and cocaine have been distinguished from benign substances based on their chemical composition. Marijuana, which chemical composition is similar to benign materials, cannot be distinguished from common organic goods. However, the detection of an unexpected organic substance inside the metallic cargo indicates that a suspicious object has been hidden in the container.

  15. Radio Detection of the Fermi-LAT Blind Search Millisecond Pulsar J1311-3430

    NASA Astrophysics Data System (ADS)

    Ray, P. S.; Ransom, S. M.; Cheung, C. C.; Giroletti, M.; Cognard, I.; Camilo, F.; Bhattacharyya, B.; Roy, J.; Romani, R. W.; Ferrara, E. C.; Guillemot, L.; Johnston, S.; Keith, M.; Kerr, M.; Kramer, M.; Pletsch, H. J.; Saz Parkinson, P. M.; Wood, K. S.

    2013-01-01

    We report the detection of radio emission from PSR J1311-3430, the first millisecond pulsar (MSP) discovered in a blind search of Fermi Large Area Telescope (LAT) gamma-ray data. We detected radio pulsations at 2 GHz, visible for <10% of ~4.5 hr of observations using the Green Bank Telescope (GBT). Observations at 5 GHz with the GBT and at several lower frequencies with Parkes, Nançay, and the Giant Metrewave Radio Telescope resulted in non-detections. We also report the faint detection of a steep spectrum continuum radio source (0.1 mJy at 5 GHz) in interferometric imaging observations with the Jansky Very Large Array. These detections demonstrate that PSR J1311-3430 is not radio quiet and provide additional evidence that radio-quiet MSPs are rare. The radio dispersion measure of 37.8 pc cm-3 provides a distance estimate of 1.4 kpc for the system, yielding a gamma-ray efficiency of 30%, typical of LAT-detected MSPs. We see apparent excess delay in the radio pulses as the pulsar appears from eclipse and we speculate on possible mechanisms for the non-detections of the pulse at other orbital phases and observing frequencies.

  16. Why do farmers and veterinarians not report all bovine abortions, as requested by the clinical brucellosis surveillance system in France?

    PubMed Central

    2014-01-01

    Background Since 2005, France has been officially free of brucellosis, an infectious disease that causes abortion in cattle and can be transmitted from cattle to humans. Recent animal and human cases have drawn attention to the need to prevent infection of humans and animals from any primary outbreaks. In order to detect any new outbreaks as soon as possible, a clinical surveillance system requires farmers and veterinarians to report each abortion and to test the aborting cow for brucellosis. However, under-reporting limits the sensitivity of this system. Our objective was to identify the barriers and motivations influencing field actors in their decision to report or not to report bovine abortions. We used a qualitative approach with semi-structured interviews of 12 cattle farmers and their eight veterinarians. Results Our analysis showed that four main themes influence the decision-making process of farmers and veterinarians: 1) the perceived risk of brucellosis and other abortive diseases; 2) the definition of a suspected case of brucellosis and other abortive diseases adopted by field actors, which is less sensitive than the mandatory definition; 3) the cost-benefit analysis conducted by actors, taking into account regulatory and health aspects, economic and financial losses, technical and practical factors; 4) the level of cooperation within the socio-technical network. We discussed how early detection may be improved by revising the definition of abortion, extending the time frame for notification and generalising the differential diagnosis of the causes of abortion. Conclusions In contrast to quantitative approaches, qualitative studies can identify the factors (including unknown factors) influencing the decision-making process of field actors and reveal why they take those factors into consideration. Our qualitative study sheds light on the factors underlying the poor sensitivity of clinical brucellosis surveillance system for cattle in France, and suggests that early detection may be improved by considering actors’ perceptions. We believe our findings may provide further insight into ways of improving other clinical surveillance systems and thus reduce the risk of disease. PMID:24762103

  17. Why do farmers and veterinarians not report all bovine abortions, as requested by the clinical brucellosis surveillance system in France?

    PubMed

    Bronner, Anne; Hénaux, Viviane; Fortané, Nicolas; Hendrikx, Pascal; Calavas, Didier

    2014-04-24

    Since 2005, France has been officially free of brucellosis, an infectious disease that causes abortion in cattle and can be transmitted from cattle to humans. Recent animal and human cases have drawn attention to the need to prevent infection of humans and animals from any primary outbreaks. In order to detect any new outbreaks as soon as possible, a clinical surveillance system requires farmers and veterinarians to report each abortion and to test the aborting cow for brucellosis. However, under-reporting limits the sensitivity of this system. Our objective was to identify the barriers and motivations influencing field actors in their decision to report or not to report bovine abortions. We used a qualitative approach with semi-structured interviews of 12 cattle farmers and their eight veterinarians. Our analysis showed that four main themes influence the decision-making process of farmers and veterinarians: 1) the perceived risk of brucellosis and other abortive diseases; 2) the definition of a suspected case of brucellosis and other abortive diseases adopted by field actors, which is less sensitive than the mandatory definition; 3) the cost-benefit analysis conducted by actors, taking into account regulatory and health aspects, economic and financial losses, technical and practical factors; 4) the level of cooperation within the socio-technical network. We discussed how early detection may be improved by revising the definition of abortion, extending the time frame for notification and generalising the differential diagnosis of the causes of abortion. In contrast to quantitative approaches, qualitative studies can identify the factors (including unknown factors) influencing the decision-making process of field actors and reveal why they take those factors into consideration. Our qualitative study sheds light on the factors underlying the poor sensitivity of clinical brucellosis surveillance system for cattle in France, and suggests that early detection may be improved by considering actors' perceptions. We believe our findings may provide further insight into ways of improving other clinical surveillance systems and thus reduce the risk of disease.

  18. Detection of Suspicious Persons using Internet Camera

    NASA Astrophysics Data System (ADS)

    Terada, Kenji; Kamogashira, Daisuke

    Recently, many brutal crimes have shocked us. Therefore, the importance of security and self-defense have increased more and more. It is necessary to develop an automatic method of detecting suspicious persons. In this paper, we propose a method of detecting suspicious persons using the internet camera. An image sequence is obtained by the internet camera. By using these images, the recognition of suspicious persons is carried out. Our method classifies the condition of the target person into 3 postures: walking, staying and sitting. The system employs the subspace method which uses three features: the value of movement, the number of looking around restlessly, and the rate of stopping and going. Some experimental results using a simple experimental system are also reported, which indicate effectiveness of the proposed method. In most scenes, the suspicious persons are able to be detected by the proposed method.

  19. Sign detection for autonomous navigation

    NASA Astrophysics Data System (ADS)

    Goodsell, Thomas G.; Snorrason, Magnus S.; Cartwright, Dustin; Stube, Brian; Stevens, Mark R.; Ablavsky, Vitaly X.

    2003-09-01

    Mobile robots currently cannot detect and read arbitrary signs. This is a major hindrance to mobile robot usability, since they cannot be tasked using directions that are intuitive to humans. It also limits their ability to report their position relative to intuitive landmarks. Other researchers have demonstrated some success on traffic sign recognition, but using template based methods limits the set of recognizable signs. There is a clear need for a sign detection and recognition system that can process a much wider variety of signs: traffic signs, street signs, store-name signs, building directories, room signs, etc. We are developing a system for Sign Understanding in Support of Autonomous Navigation (SUSAN), that detects signs from various cues common to most signs: vivid colors, compact shape, and text. We have demonstrated the feasibility of our approach on a variety of signs in both indoor and outdoor locations.

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    X. Zhao, S. Ramakrishnan, J. Lawson, C.Neumeyer, R. Marsala, H. Schneider, Engineering Operations

    NSTX at Princeton Plasma Physics Laboratory (PPPL) requires sophisticated plasma positioning control system for stable plasma operation. TF magnetic coils and PF magnetic coils provide electromagnetic fields to position and shape the plasma vertically and horizontally respectively. NSTX utilizes twenty six coil power supplies to establish and initiate electromagnetic fields through the coil system for plasma control. A power protection and interlock system is utilized to detect power system faults and protect the TF coils and PF coils against excessive electromechanical forces, overheating, and over current. Upon detecting any fault condition the power system is restricted, and it is eithermore » prevented from initializing or suppressed to de-energize coil power during pulsing. Power fault status is immediately reported to the computer system. This paper describes the design and operation of NSTX's protection and interlocking system and possible future expansion.« less

Top