46 CFR 95.05-1 - Fire detecting, manual alarm, and supervised patrol systems.
Code of Federal Regulations, 2014 CFR
2014-10-01
... provided a smoke detecting or other suitable type fire detecting system. (c) Enclosed spaces which are “specially suitable for vehicles” shall be fitted with an approved fire or smoke detecting system. [CGFR 66...
46 CFR 95.05-1 - Fire detecting, manual alarm, and supervised patrol systems.
Code of Federal Regulations, 2013 CFR
2013-10-01
... provided a smoke detecting or other suitable type fire detecting system. (c) Enclosed spaces which are “specially suitable for vehicles” shall be fitted with an approved fire or smoke detecting system. [CGFR 66...
Methods, compounds and systems for detecting a microorganism in a sample
Colston, Jr, Bill W.; Fitch, J. Patrick; Gardner, Shea N.; Williams, Peter L.; Wagner, Mark C.
2016-09-06
Methods to identify a set of probe polynucleotides suitable for detecting a set of targets and in particular methods for identification of primers suitable for detection of target microorganisms related polynucleotides, set of polynucleotides and compositions, and related methods and systems for detection and/or identification of microorganisms in a sample.
DOT National Transportation Integrated Search
2007-12-01
Vehicle-based alcohol detection systems use technologies designed to detect the presence of alcohol in a driver. Technology suitable for use in all vehicles that will detect an impaired driver faces many challenges including public acceptability, pas...
NASA Astrophysics Data System (ADS)
Vakoch, Douglas A.; Dowd, Matthew F.; Drake, Frank
2015-07-01
List of contributors; Foreword Frank Drake; Preface; Acknowledgements; Introduction Steven Dick; 1. Rate of formation of stars suitable for the development of intelligent life, R*, pre-1961 David DeVorkin; 2. Rate of formation of stars suitable for the development of intelligent life, R*, 1961 to the present Patrick François and Danielle Briot; 3. Fraction of stars with planetary systems, fp, pre-1961 Matthew F. Dowd; 4. Fraction of stars with planetary systems, fp, 1961 to the present Chris Impey; 5. Number of planets, per solar system, with an environment suitable for life, ne, pre-1961 Florence Raulin Cerceau; 6. Number of planets, per solar system, with an environment suitable for life, ne, 1961 to the present Danielle Briot and Jean Schneider; 7. Fraction of suitable planets on which life actually appears, fl, pre-1961 Stephané Tirard; 8. Fraction of suitable planets on which life actually appears, fl, 1961 to the present David J. Des Marais; 9. Fraction of life-bearing planets on which intelligent life emerges, fl, pre-1961 Michael Crowe; 10. Fraction of life-bearing planets on which intelligent life emerges, fl, 1961 to the present Lori Marino; 11. Fraction of civilizations that develop a technology that releases detectable signs of their existence into space, fc, pre-1961 Florence Raulin Cerceau; 12. Fraction of civilizations that develop a technology that releases detectable signs of their existence into space, fc, 1961 to the present Seth Shostak; 13. Length of time such civilizations release detectable signals into space, L, pre-1961 David Dunér; 14. Length of time such civilizations release detectable signals into space, L, 1961 to the present Garry Chick; Afterword Paul Davies; Index.
46 CFR 111.05-25 - Ungrounded systems.
Code of Federal Regulations, 2010 CFR
2010-10-01
... REQUIREMENTS Equipment Ground, Ground Detection, and Grounded Systems § 111.05-25 Ungrounded systems. Each ungrounded system must be provided with a suitably sensitive ground detection system located at the... 46 Shipping 4 2010-10-01 2010-10-01 false Ungrounded systems. 111.05-25 Section 111.05-25 Shipping...
Nucleic acid detection system and method for detecting influenza
Cai, Hong; Song, Jian
2015-03-17
The invention provides a rapid, sensitive and specific nucleic acid detection system which utilizes isothermal nucleic acid amplification in combination with a lateral flow chromatographic device, or DNA dipstick, for DNA-hybridization detection. The system of the invention requires no complex instrumentation or electronic hardware, and provides a low cost nucleic acid detection system suitable for highly sensitive pathogen detection. Hybridization to single-stranded DNA amplification products using the system of the invention provides a sensitive and specific means by which assays can be multiplexed for the detection of multiple target sequences.
Tillman, J E
1953-10-20
This patent application describes a sensitive detection or protective system capable of giving an alarm or warning upon the entrance or intrusion of any body into a defined area or zone protected by a radiation field of suitable direction or extent.
Evanescent field Sensors Based on Tantalum Pentoxide Waveguides – A Review
Schmitt, Katrin; Oehse, Kerstin; Sulz, Gerd; Hoffmann, Christian
2008-01-01
Evanescent field sensors based on waveguide surfaces play an important role where high sensitivity is required. Particularly tantalum pentoxide (Ta2O5) is a suitable material for thin-film waveguides due to its high refractive index and low attenuation. Many label-free biosensor systems such as grating couplers and interferometric sensors as well as fluorescence-based systems benefit from this waveguide material leading to extremely high sensitivity. Some biosensor systems based on Ta2O5 waveguides already took the step into commercialization. This report reviews the various detection systems in terms of limit of detection, the applications, and the suitable surface chemistry. PMID:27879731
2013-07-01
detection system available will simply register events resulting from natural background radiation if a suitable source emission is not employed. The...random fluctuations in the natural background radiation level. Noise within the detection system can result from any of the various components that...Uritani et al., 1994). Nothing can generally be done to reduce or stabilize the amount of natural background radiation present for nonstationary
Almeida, Jamie L.; Wang, Lili; Morrow, Jayne B.; Cole, Kenneth D.
2006-01-01
Bacillus anthracis spores have been used as biological weapons and the possibility of their further use requires surveillance systems that can accurately and reliably detect their presence in the environment. These systems must collect samples from a variety of matrices, process the samples, and detect the spores. The processing of the sample may include removal of inhibitors, concentration of the target, and extraction of the target in a form suitable for detection. Suitable reference materials will allow the testing of each of these steps to determine the sensitivity and specificity of the detection systems. The development of uniform and well-characterized reference materials will allow the comparison of different devices and technologies as well as assure the continued performance of detection systems. This paper discusses the special requirements of reference materials for Bacillus anthracis spores that could be used for testing detection systems. The detection of Bacillus anthracis spores is based on recognition of specific characteristics (markers) on either the spore surface or in the nucleic acids (DNA). We have reviewed the specific markers and their relevance to characterization of reference materials. We have also included the approach for the characterization of candidate reference materials that we are developing at the NIST laboratories. Additional applications of spore reference materials would include testing sporicidal treatments, techniques for sampling the environment, and remediation of spore-contaminated environments. PMID:27274929
NASA Astrophysics Data System (ADS)
Ojaghi, Ashkan; Parkhimchyk, Artur; Tabatabaei, Nima
2016-09-01
Early detection of the most prevalent oral disease worldwide, i.e., dental caries, still remains as one of the major challenges in dentistry. The current dental standard of care relies on caries detection methods, such as visual inspection and x-ray radiography, which lack the sufficient specificity and sensitivity to detect caries at early stages of formation when they can be healed. We report on the feasibility of early caries detection in a clinically and commercially viable thermophotonic imaging system. The system incorporates intensity-modulated laser light along with a low-cost long-wavelength infrared (LWIR; 8 to 14 μm) camera, providing diagnostic contrast based on the enhanced light absorption of early caries. The LWIR camera is highly suitable for integration into clinical platforms because of its low weight and cost. In addition, through theoretical modeling, we show that LWIR detection enhances the diagnostic contrast due to the minimal LWIR transmittance of enamel and suppression of the masking effect of the direct thermal Planck emission. Diagnostic performance of the system and its detection threshold are experimentally evaluated by monitoring the inception and progression of artificially induced occlusal and smooth surface caries. The results are suggestive of the suitability of the developed LWIR system for detecting early dental caries.
Liquefied Noble Gas (LNG) detectors for detection of nuclear materials
NASA Astrophysics Data System (ADS)
Nikkel, J. A.; Gozani, T.; Brown, C.; Kwong, J.; McKinsey, D. N.; Shin, Y.; Kane, S.; Gary, C.; Firestone, M.
2012-03-01
Liquefied-noble-gas (LNG) detectors offer, in principle, very good energy resolution for both neutrons and gamma rays, fast response time (hence high-count-rate capabilities), excellent discrimination between neutrons and gamma rays, and scalability to large volumes. They do, however, need cryogenics. LNG detectors in sizes of interest for fissionable material detection in cargo are reaching a certain level of maturity because of the ongoing extensive R&}D effort in high-energy physics regarding their use in the search for dark matter and neutrinoless double beta decay. The unique properties of LNG detectors, especially those using Liquid Argon (LAr) and Liquid Xenon (LXe), call for a study to determine their suitability for Non-Intrusive Inspection (NII) for Special Nuclear Materials (SNM) and possibly for other threats in cargo. Rapiscan Systems Laboratory, Yale University Physics Department, and Adelphi Technology are collaborating in the investigation of the suitability of LAr as a scintillation material for large size inspection systems for air and maritime containers and trucks. This program studies their suitability for NII, determines their potential uses, determines what improvements in performance they offer and recommends changes to their design to further enhance their suitability. An existing 3.1 liter LAr detector (microCLEAN) at Yale University, developed for R&}D on the detection of weakly interacting massive particles (WIMPs) was employed for testing. A larger version of this detector (15 liters), more suitable for the detection of higher energy gamma rays and neutrons is being built for experimental evaluation. Results of measurements and simulations of gamma ray and neutron detection in microCLEAN and a larger detector (326 liter CL38) are presented.
46 CFR 28.325 - Fire detection systems.
Code of Federal Regulations, 2010 CFR
2010-10-01
... space must be equipped with an independent modular smoke detector or a smoke actuated fire detecting... detector must meet UL 217 and be listed as a “Single Station Smoke Detector—Also suitable for use in...
46 CFR 28.325 - Fire detection systems.
Code of Federal Regulations, 2013 CFR
2013-10-01
... space must be equipped with an independent modular smoke detector or a smoke actuated fire detecting... detector must meet UL 217 and be listed as a “Single Station Smoke Detector—Also suitable for use in...
46 CFR 28.325 - Fire detection systems.
Code of Federal Regulations, 2011 CFR
2011-10-01
... space must be equipped with an independent modular smoke detector or a smoke actuated fire detecting... detector must meet UL 217 and be listed as a “Single Station Smoke Detector—Also suitable for use in...
46 CFR 28.325 - Fire detection systems.
Code of Federal Regulations, 2014 CFR
2014-10-01
... space must be equipped with an independent modular smoke detector or a smoke actuated fire detecting... detector must meet UL 217 and be listed as a “Single Station Smoke Detector—Also suitable for use in...
46 CFR 28.325 - Fire detection systems.
Code of Federal Regulations, 2012 CFR
2012-10-01
... space must be equipped with an independent modular smoke detector or a smoke actuated fire detecting... detector must meet UL 217 and be listed as a “Single Station Smoke Detector—Also suitable for use in...
Development of a Multi-Sensor Cancer Detection Probe Final Report CRADA No. TC-2026-01
DOE Office of Scientific and Technical Information (OSTI.GOV)
Marion, J.; Hular, R.
This collaboration continued work started under a previous CRADA (TSB-2023-00) to take a detailed concept specification for a multi-sensor needle/probe suitable for breast cancer analysis and produce a prototype system suitable for human FDA trials.
Detection of IL-6 by magnetic nanoparticles grown with the assistance of mid-infrared lighting.
Jiang, Xiufeng; Zhang, Ye; Miao, Xiaofei; Li, Zenghui; Bao, Zengtao; Wang, Tong
2013-01-01
Nanomedical systems have attracted considerable attention primarily due to suitability in applications for specific cell selection through biomolecular targeting and rare cell detection enhancement in a diverse, multicellular population. In the present study, magnetic nanoparticles were prepared for use in high accuracy cell sensing. Magnetic nanoparticle growth was assisted by mid-infrared lighting. By this mechanism, a narrow window, estimated to be 2%, was achieved for the dimension distribution of grown nanoparticles. Combined with silicon nanowire (SiNW) transistors, a sensor with ultra high sensitivity for the detection of specific potential low abundance biomarkers has been achieved, which has been specifically used to detect interleukin-6 (IL-6) at extremely low concentrations. A novel biosensor with high sensitivity has been fabricated and utilized in the detection of IL-6 at 75 fM to 50 pM. The system consists of an SiNW transistor and magnetic nanoparticles with even dimension distribution. The novel sensor system is suitable for quantifying IL-6 at low concentrations in protein samples.
Development of RAP Tag, a Novel Tagging System for Protein Detection and Purification.
Fujii, Yuki; Kaneko, Mika K; Ogasawara, Satoshi; Yamada, Shinji; Yanaka, Miyuki; Nakamura, Takuro; Saidoh, Noriko; Yoshida, Kanae; Honma, Ryusuke; Kato, Yukinari
2017-04-01
Affinity tag systems, possessing high affinity and specificity, are useful for protein detection and purification. The most suitable tag for a particular purpose should be selected from many available affinity tag systems. In this study, we developed a novel affinity tag called the "RAP tag" system, which comprises a mouse antirat podoplanin monoclonal antibody (clone PMab-2) and the RAP tag (DMVNPGLEDRIE). This system is useful not only for protein detection in Western blotting, flow cytometry, and sandwich enzyme-linked immunosorbent assay, but also for protein purification.
UAV-borne X-band radar for MAV collision avoidance
NASA Astrophysics Data System (ADS)
Moses, Allistair A.; Rutherford, Matthew J.; Kontitsis, Michail; Valavanis, Kimon P.
2011-05-01
Increased use of Miniature (Unmanned) Aerial Vehicles (MAVs) is coincidentally accompanied by a notable lack of sensors suitable for enabling further increases in levels of autonomy and consequently, integration into the National Airspace System (NAS). The majority of available sensors suitable for MAV integration are based on infrared detectors, focal plane arrays, optical and ultrasonic rangefinders, etc. These sensors are generally not able to detect or identify other MAV-sized targets and, when detection is possible, considerable computational power is typically required for successful identification. Furthermore, performance of visual-range optical sensor systems can suffer greatly when operating in the conditions that are typically encountered during search and rescue, surveillance, combat, and most common MAV applications. However, the addition of a miniature radar system can, in consort with other sensors, provide comprehensive target detection and identification capabilities for MAVs. This trend is observed in manned aviation where radar systems are the primary detection and identification sensor system. Within this document a miniature, lightweight X-Band radar system for use on a miniature (710mm rotor diameter) rotorcraft is described. We present analyses of the performance of the system in a realistic scenario with two MAVs. Additionally, an analysis of MAV navigation and collision avoidance behaviors is performed to determine the effect of integrating radar systems into MAV-class vehicles.
Development of a new 26plex Y-STRs typing system for forensic application.
Zhang, Suhua; Tian, Huaizhou; Wang, Zheng; Zhao, Shumin; Hu, Zhen; Li, Chengtao; Ji, Chaoneng
2014-11-01
In this study, 26plex Y-STRs typing system, including 17 Y-STRs (DYS19, DYS389I, DYS389II, DYS390, DYS391, DYS392, DYS393, DYS385ab, DYS437, DYS438, DYS439, DYS448, DYS456, DYS458, DYS635 and GATA H4) recommended as YHRD standard loci and nine new highly discriminating Y-STRs (DYS549, DYS643, DYS388, DYS570, DYS533, DYS576, DYS460, DYS481 and DYS449), was established with 5-dye fluorescences labelling. Developmental validation indicated that the 26plex Y-STRs typing system was reproducible, accurate, sensitive and robust. The sensitivity of the system was such that a full profile was obtainable even with 125pg of male DNA. Specificity testing was demonstrated by the lack of cross-reactivity with a variety of commonly encountered animal species and bacteria. Also, the multiplex is suitable for mixture study. An average of above 97% of the minor alleles detected with the male/male mixture with 1:3 and 3:1 ratios, while an average of above 70% of the minor alleles detected with the male/male mixture with 1:19 and 19:1 ratios. Full profiles are consistently detected with 125pg of male DNA, even in the presence of excessive amounts of female DNA. In addition, the whole PCR amplification of the 26 Y-STRs can finish in 1h, making the multiplex system suitable for fast-detection. For the forensic evaluation of the multiplex system, 516 haplotypes were found among 517 unrelated males. HD of the multiplex system was 0.9999925 while DC was 0.9980658, which is suitable for forensic application. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
46 CFR 120.378 - Ungrounded systems.
Code of Federal Regulations, 2010 CFR
2010-10-01
... and Distribution Systems § 120.378 Ungrounded systems. Each ungrounded system must be provided with a suitably sensitive ground detection system, located at the respective switchboard, that provides continuous... 46 Shipping 4 2010-10-01 2010-10-01 false Ungrounded systems. 120.378 Section 120.378 Shipping...
46 CFR 120.378 - Ungrounded systems.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Ungrounded systems. 120.378 Section 120.378 Shipping... and Distribution Systems § 120.378 Ungrounded systems. Each ungrounded system must be provided with a suitably sensitive ground detection system, located at the respective switchboard, that provides continuous...
46 CFR 120.378 - Ungrounded systems.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Ungrounded systems. 120.378 Section 120.378 Shipping... and Distribution Systems § 120.378 Ungrounded systems. Each ungrounded system must be provided with a suitably sensitive ground detection system, located at the respective switchboard, that provides continuous...
46 CFR 183.378 - Ungrounded systems.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 7 2014-10-01 2014-10-01 false Ungrounded systems. 183.378 Section 183.378 Shipping...) ELECTRICAL INSTALLATION Power Sources and Distribution Systems § 183.378 Ungrounded systems. Each ungrounded system must be provided with a suitably sensitive ground detection system located at the respective...
46 CFR 120.378 - Ungrounded systems.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Ungrounded systems. 120.378 Section 120.378 Shipping... and Distribution Systems § 120.378 Ungrounded systems. Each ungrounded system must be provided with a suitably sensitive ground detection system, located at the respective switchboard, that provides continuous...
46 CFR 183.378 - Ungrounded systems.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 7 2010-10-01 2010-10-01 false Ungrounded systems. 183.378 Section 183.378 Shipping...) ELECTRICAL INSTALLATION Power Sources and Distribution Systems § 183.378 Ungrounded systems. Each ungrounded system must be provided with a suitably sensitive ground detection system located at the respective...
Cao, Xiaohuang; Zhang, Min; Qian, He; Mujumdar, Arun S
2017-06-01
An online temperature-detection-assisted control system of microwave-assisted pulse-spouted vacuum drying was newly developed. By using this system, temperature control can be automatically and continuously adjusted based on the detection of drying temperature and preset temperature. Various strategies for constant temperature control, linear temperature control and three-step temperature control were applied to drying carrot cubes. Drying kinetics and the quality of various temperature-controlled strategies online are evaluated for the new drying technology as well as its suitability as an alternative drying method. Drying time in 70 °C mode 1 had the shortest drying time and lowest energy consumption in all modes. A suitable colour, highest re-hydration ratio and fracture-hardness, and longest drying time occurred in 30-40-50 °C mode 3. The number of hot spots was reduced in 40-50-60 °C mode 3. Acceptable carrot snacks were obtained in 50-60-70 °C mode 3 and 70 °C mode 2. All temperature curves showed that the actual temperatures followed the preset temperatures appropriately. With this system, a linear temperature-controlled strategy and a three-step temperature-controlled strategy can improve product quality and heating non-uniformity compared to constant temperature control, but need greater energy consumption and longer drying time. A temperature-detection-assisted control system was developed for providing various drying strategies as a suitable alternative in making a snack product. © 2016 Society of Chemical Industry. © 2016 Society of Chemical Industry.
Mertens, Melanie; Brehler, Randolf
2011-01-01
In hymenoptera venom allergy, about 75% of detected in vitro double positivity to yellow jacket and honeybee venom is ascribed to specific IgE (sIgE) directed against cross-reactive carbohydrate determinants (CCDs). To date, for the detection of CCD-sIgE, different carbohydrate antigens and methods are used. The most suitable one still has to be identified. Eighty-seven patients with confirmed hymenoptera venom allergy and venom sIgE values of ≥0.7 kU/l were investigated. Sixty-five patients showed sIgE reactivity to both yellow jacket and honeybee venom, 22 were venom mono positive and served as controls. Occurrence of CCD-sIgE was determined using bromelain, horseradish peroxidase (HRP) and MUXF(3) on system A, and ascorbic acid oxidase (AAO), bromelain and HRP on system B. Further, a reference standard for CCD-sIgE evaluation was created: CCD positivity was assumed when at least 4 of the 6 test results were positive. According to the defined reference standard, 45/65 venom double positive patients exhibited CCD-sIgE. Using system A, comparison with the reference standard revealed sensitivity and specificity values of 96 and 97%, respectively, for MUXF(3), 100 and 100%, respectively, for bromelain, and 96 and 97%, respectively, for HRP. Using system B, sensitivity and specificity was 98 and 97%, respectively, for AAO, 62 and 95%, respectively, for bromelain, and 96 and 69%, respectively, for HRP. Results of the 3 test allergens obtained with system A showed strong correlations (r = 0.932-0.976), whereas results with system B showed lower correlations (r = 0.714-0.898). All 3 test allergens used with system A are suitable for CCD-sIgE detection in hymenoptera venom allergy. With system B, only AAO seems to be a reliable tool. Copyright © 2011 S. Karger AG, Basel.
The Transiting Exocomets of HD 172555
NASA Technical Reports Server (NTRS)
Grady, C. A.; Brown, Alex; Kamp, Inga; Riviere-Marichalar, Pablo; Roberge, Aki; Welsh, Barry
2016-01-01
While most attention has been garnered by searches for super-Jovian mass exo-planets the presence of minor bodies can be detected, at least through their dissociation products in suitably oriented systems. The principal detection technique is line-of-sight absorption spectroscopy of systems viewed close to edge-on. I review what we have learned about such bodies in beta Pictoris, and HD 172555, their link to more massive bodies in their systems, and what this tells us about the frequency and potential locations of Jovian-mass bodies in advance of their direct imaging detection.
Confocal Laser Scanning Microscopy, a New In Vivo Diagnostic Tool for Schistosomiasis
Holtfreter, Martha Charlotte; Nohr-Łuczak, Constanze; Guthoff, Rudolf Friedrich; Reisinger, Emil Christian
2012-01-01
Background The gold standard for the diagnosis of schistosomiasis is the detection of the parasite's characteristic eggs in urine, stool, or rectal and bladder biopsy specimens. Direct detection of eggs is difficult and not always possible in patients with low egg-shedding rates. Confocal laser scanning microscopy (CLSM) permits non-invasive cell imaging in vivo and is an established way of obtaining high-resolution images and 3-dimensional reconstructions. Recently, CLSM was shown to be a suitable method to visualize Schistosoma mansoni eggs within the mucosa of dissected mouse gut. In this case, we evaluated the suitability of CLSM to detect eggs of Schistosoma haematobium in a patient with urinary schistosomiasis and low egg-shedding rates. Methodology/Principal Findings The confocal laser scanning microscope used in this study was based on a scanning laser system for imaging the retina of a living eye, the Heidelberg Retina Tomograph II, in combination with a lens system (image modality). Standard light cystoscopy was performed using a rigid cystoscope under general anaesthesia. The CLSM endoscope was then passed through the working channel of the rigid cystoscope. The mucosal tissue of the bladder was scanned using CLSM. Schistoma haematobium eggs appeared as bright structures, with the characteristic egg shape and typical terminal spine. Conclusion/Significance We were able to detect schistosomal eggs in the urothelium of a patient with urinary schistosomiasis. Thus, CLSM may be a suitable tool for the diagnosis of schistosomiasis in humans, especially in cases where standard diagnostic tools are not suitable. PMID:22529947
Automated analysis of oxidative metabolites
NASA Technical Reports Server (NTRS)
Furner, R. L. (Inventor)
1974-01-01
An automated system for the study of drug metabolism is described. The system monitors the oxidative metabolites of aromatic amines and of compounds which produce formaldehyde on oxidative dealkylation. It includes color developing compositions suitable for detecting hyroxylated aromatic amines and formaldehyde.
46 CFR 111.05-29 - Dual voltage direct current systems.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Dual voltage direct current systems. Each dual voltage direct current system must have a suitably sensitive ground detection system which indicates current in the ground connection, has a range of at least... 46 Shipping 4 2010-10-01 2010-10-01 false Dual voltage direct current systems. 111.05-29 Section...
46 CFR 111.05-29 - Dual voltage direct current systems.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Dual voltage direct current systems. Each dual voltage direct current system must have a suitably sensitive ground detection system which indicates current in the ground connection, has a range of at least... 46 Shipping 4 2011-10-01 2011-10-01 false Dual voltage direct current systems. 111.05-29 Section...
[Detection of circulating tumor cells in patients with hepatocellular carcinoma].
Mu, Hong; Lin, Kaixuan; Zhao, Hong; Li, Cong; Sun, Yulin; Cai, Jianqiang; Zhao, Xiaohang
2014-04-01
To explore the detection efficiency of circulating tumor cells (CTCs) in patients with hepatocellular carcinoma (HCC). Immunomagnetic negative enrichment by nanometer magnetic beads and label-free capture with Captor(TM) system were used to isolate and enrich CTCs from peripheral blood of HCC patients, and epithelial and HCC markers were applied to identify CTCs by immunofluorescence staining. CTCs were detected in 50 HCC patients before and after hepatectomy to test the method for isolation, enrichment and identification. The dynamic changes of pre- and post-operative CTCs' numbers were compared. The clinical data were analyzed using SPSS 19.0 software. Negative enrichment methods by nanometer magnetic beads and label-free capture using Captor(TM) system were both suitable for CTCs isolation and enrichment in HCC patients. The positive detection rate of CTCs in HCC patients via negative enrichment was 96.0% (48/50), the preoperative median number of CTCs was 16 per 7.5 ml blood, and the postoperative median number was 17 per 7.5 ml blood. Both negative enrichment and Captor(TM) system are suitable for isolation and enrichment of CTCs in HCC patients. There is a significant difference in the numbers of CTCs before and after operation, and dynamic detection of CTCs will provide helpful prognostic information for HCC patients in clinics.
Error Detection in Mechanized Classification Systems
ERIC Educational Resources Information Center
Hoyle, W. G.
1976-01-01
When documentary material is indexed by a mechanized classification system, and the results judged by trained professionals, the number of documents in disagreement, after suitable adjustment, defines the error rate of the system. In a test case disagreement was 22 percent and, of this 22 percent, the computer correctly identified two-thirds of…
Dou, Maowei; Lopez, Juan; Rios, Misael; Garcia, Oscar; Xiao, Chuan; Eastman, Michael
2016-01-01
A cost-effective battery-powered spectrophotometric system (BASS) was developed for quantitative point-of-care (POC) analysis on a microfluidic chip. By using methylene blue as a model analyte, we first compared the performance of the BASS with a commercial spectrophotometric system, and further applied the BASS for loop-mediated isothermal amplification (LAMP) detection and subsequent quantitative nucleic acid analysis which exhibited a comparable limit of detection to that of Nanodrop. Compared to the commercial spectrophotometric system, our spectrophotometric system is lower-cost, consumes less reagents, and has a higher detection sensitivity. Most importantly, it does not rely on external power supplies. All these features make our spectrophotometric system highly suitable for a variety of POC analyses, such as field detection. PMID:27143408
Microwave frequency sensor for detection of biological cells in microfluidic channels.
Nikolic-Jaric, M; Romanuik, S F; Ferrier, G A; Bridges, G E; Butler, M; Sunley, K; Thomson, D J; Freeman, M R
2009-08-12
We present details of an apparatus for capacitive detection of biomaterials in microfluidic channels operating at microwave frequencies where dielectric effects due to interfacial polarization are minimal. A circuit model is presented, which can be used to adapt this detection system for use in other microfluidic applications and to identify ones where it would not be suitable. The detection system is based on a microwave coupled transmission line resonator integrated into an interferometer. At 1.5 GHz the system is capable of detecting changes in capacitance of 650 zF with a 50 Hz bandwidth. This system is well suited to the detection of biomaterials in a variety of suspending fluids, including phosphate-buffered saline. Applications involving both model particles (polystyrene microspheres) and living cells-baker's yeast (Saccharomyces cerevisiae) and Chinese hamster ovary cells-are presented.
46 CFR 28.830 - Fire detection system.
Code of Federal Regulations, 2011 CFR
2011-10-01
... must be equipped with an independent modular smoke detector or a smoke actuated fire detecting unit installed in accordance with § 76.33 of this chapter. (b) An independent modular smoke detector must meet UL 217 and be listed as a “Single Station Smoke Detector—Also Suitable for Use in Recreational Vehicles”. ...
46 CFR 28.830 - Fire detection system.
Code of Federal Regulations, 2013 CFR
2013-10-01
... must be equipped with an independent modular smoke detector or a smoke actuated fire detecting unit installed in accordance with § 76.33 of this chapter. (b) An independent modular smoke detector must meet UL 217 and be listed as a “Single Station Smoke Detector—Also Suitable for Use in Recreational Vehicles”. ...
46 CFR 28.830 - Fire detection system.
Code of Federal Regulations, 2010 CFR
2010-10-01
... must be equipped with an independent modular smoke detector or a smoke actuated fire detecting unit installed in accordance with § 76.33 of this chapter. (b) An independent modular smoke detector must meet UL 217 and be listed as a “Single Station Smoke Detector—Also Suitable for Use in Recreational Vehicles”. ...
46 CFR 28.830 - Fire detection system.
Code of Federal Regulations, 2012 CFR
2012-10-01
... must be equipped with an independent modular smoke detector or a smoke actuated fire detecting unit installed in accordance with § 76.33 of this chapter. (b) An independent modular smoke detector must meet UL 217 and be listed as a “Single Station Smoke Detector—Also Suitable for Use in Recreational Vehicles”. ...
46 CFR 28.830 - Fire detection system.
Code of Federal Regulations, 2014 CFR
2014-10-01
... must be equipped with an independent modular smoke detector or a smoke actuated fire detecting unit installed in accordance with § 76.33 of this chapter. (b) An independent modular smoke detector must meet UL 217 and be listed as a “Single Station Smoke Detector—Also Suitable for Use in Recreational Vehicles”. ...
Identification of suitable fundus images using automated quality assessment methods.
Şevik, Uğur; Köse, Cemal; Berber, Tolga; Erdöl, Hidayet
2014-04-01
Retinal image quality assessment (IQA) is a crucial process for automated retinal image analysis systems to obtain an accurate and successful diagnosis of retinal diseases. Consequently, the first step in a good retinal image analysis system is measuring the quality of the input image. We present an approach for finding medically suitable retinal images for retinal diagnosis. We used a three-class grading system that consists of good, bad, and outlier classes. We created a retinal image quality dataset with a total of 216 consecutive images called the Diabetic Retinopathy Image Database. We identified the suitable images within the good images for automatic retinal image analysis systems using a novel method. Subsequently, we evaluated our retinal image suitability approach using the Digital Retinal Images for Vessel Extraction and Standard Diabetic Retinopathy Database Calibration level 1 public datasets. The results were measured through the F1 metric, which is a harmonic mean of precision and recall metrics. The highest F1 scores of the IQA tests were 99.60%, 96.50%, and 85.00% for good, bad, and outlier classes, respectively. Additionally, the accuracy of our suitable image detection approach was 98.08%. Our approach can be integrated into any automatic retinal analysis system with sufficient performance scores.
Völker, S; Schreiber, C; Müller, H; Zacharias, N; Kistemann, T
2017-05-01
After the amendment of the Drinking Water Ordinance in 2011, the requirements for the hygienic-microbiological monitoring of drinking water installations have increased significantly. In the BMBF-funded project "Biofilm Management" (2010-2014), we examined the extent to which established sampling strategies in practice can uncover drinking water plumbing systems systemically colonized with Legionella. Moreover, we investigated additional parameters that might be suitable for detecting systemic contaminations. We subjected the drinking water plumbing systems of 8 buildings with known microbial contamination (Legionella) to an intensive hygienic-microbiological sampling with high spatial and temporal resolution. A total of 626 drinking hot water samples were analyzed with classical culture-based methods. In addition, comprehensive hygienic observations were conducted in each building and qualitative interviews with operators and users were applied. Collected tap-specific parameters were quantitatively analyzed by means of sensitivity and accuracy calculations. The systemic presence of Legionella in drinking water plumbing systems has a high spatial and temporal variability. Established sampling strategies were only partially suitable to detect long-term Legionella contaminations in practice. In particular, the sampling of hot water at the calorifier and circulation re-entrance showed little significance in terms of contamination events. To detect the systemic presence of Legionella,the parameters stagnation (qualitatively assessed) and temperature (compliance with the 5K-rule) showed better results. © Georg Thieme Verlag KG Stuttgart · New York.
Non-iterative Voltage Stability
DOE Office of Scientific and Technical Information (OSTI.GOV)
Makarov, Yuri V.; Vyakaranam, Bharat; Hou, Zhangshuan
2014-09-30
This report demonstrates promising capabilities and performance characteristics of the proposed method using several power systems models. The new method will help to develop a new generation of highly efficient tools suitable for real-time parallel implementation. The ultimate benefit obtained will be early detection of system instability and prevention of system blackouts in real time.
A Multi-Channel Method for Detecting Periodic Forced Oscillations in Power Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Follum, James D.; Tuffner, Francis K.
2016-11-14
Forced oscillations in electric power systems are often symptomatic of equipment malfunction or improper operation. Detecting and addressing the cause of the oscillations can improve overall system operation. In this paper, a multi-channel method of detecting forced oscillations and estimating their frequencies is proposed. The method operates by comparing the sum of scaled periodograms from various channels to a threshold. A method of setting the threshold to specify the detector's probability of false alarm while accounting for the correlation between channels is also presented. Results from simulated and measured power system data indicate that the method outperforms its single-channel counterpartmore » and is suitable for real-world applications.« less
Decision-feedback detection strategy for nonlinear frequency-division multiplexing
NASA Astrophysics Data System (ADS)
Civelli, Stella; Forestieri, Enrico; Secondini, Marco
2018-04-01
By exploiting a causality property of the nonlinear Fourier transform, a novel decision-feedback detection strategy for nonlinear frequency-division multiplexing (NFDM) systems is introduced. The performance of the proposed strategy is investigated both by simulations and by theoretical bounds and approximations, showing that it achieves a considerable performance improvement compared to previously adopted techniques in terms of Q-factor. The obtained improvement demonstrates that, by tailoring the detection strategy to the peculiar properties of the nonlinear Fourier transform, it is possible to boost the performance of NFDM systems and overcome current limitations imposed by the use of more conventional detection techniques suitable for the linear regime.
Failure Detecting Method of Fault Current Limiter System with Rectifier
NASA Astrophysics Data System (ADS)
Tokuda, Noriaki; Matsubara, Yoshio; Asano, Masakuni; Ohkuma, Takeshi; Sato, Yoshibumi; Takahashi, Yoshihisa
A fault current limiter (FCL) is extensively needed to suppress fault current, particularly required for trunk power systems connecting high-voltage transmission lines, such as 500kV class power system which constitutes the nucleus of the electric power system. We proposed a new type FCL system (rectifier type FCL), consisting of solid-state diodes, DC reactor and bypass AC reactor, and demonstrated the excellent performances of this FCL by developing the small 6.6kV and 66kV model. It is important to detect the failure of power devices used in the rectifier under the normal operating condition, for keeping the excellent reliability of the power system. In this paper, we have proposed a new failure detecting method of power devices most suitable for the rectifier type FCL. This failure detecting system is simple and compact. We have adapted the proposed system to the 66kV prototype single-phase model and successfully demonstrated to detect the failure of power devices.
Xu, Yao; Zheng, Zhi
2016-05-15
We have developed a convenient, robust and low-cost RNA detection system suitable for high-throughput applications. This system uses a highly specific sandwich hybridization to capture target RNA directly onto solid support, followed by on-site signal amplification via 2-dimensional, branched hybridizing chain polymerization through toehold-mediated strand displacement reaction. The assay uses SYBR Green to detect targets at concentrations as low as 1 pM, without involving nucleic acid purification or any enzymatic reaction, using ordinary oligonucleotides without modification or labeling. The system was demonstrated in the detection of malaria RNA in blood and GAPDH gene expression in cell lysate. Copyright © 2015 Elsevier B.V. All rights reserved.
Transient response measurements on a satellite system
NASA Technical Reports Server (NTRS)
Nanevicz, J. E.; Adamo, R. C.
1977-01-01
A set of instruments designed to detect the occurance of electrical breakdown was flown on a synchronous-orbit satellite. The LeRC sensors were installed on cables inside the vehicle. Accordingly, they respond to signals coupled into the satellite wiring system. The SRI sensors were located on the exterior of the vehicle and detected the RF noise pulses associated with surface breakdowns. The results of the earlier SRI program are being used to design and develop a set of intrumentation suitable for inclusion as a general piggy-back package for the detection of the onset of satellite charging and breakdowns on synchronous orbit satellites.
Eddy current system for inspection of train hollow axles
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chady, Tomasz; Psuj, Grzegorz; Sikora, Ryszard
2014-02-18
The structural integrity of wheelsets used in rolling stock is of great importance to the safety. In this paper, electromagnetic system with an eddy current transducer suitable for the inspection of hollow axles have been presented. The transducer was developed to detect surface braking defects having depth not smaller than 0.5 mm. Ultrasound technique can be utilized to inspect the whole axle, but it is not sufficiently sensitive to shallow defects located close to the surface. Therefore, the electromagnetic technique is proposed to detect surface breaking cracks that cannot be detected by ultrasonic technique.
Particle Filters for Real-Time Fault Detection in Planetary Rovers
NASA Technical Reports Server (NTRS)
Dearden, Richard; Clancy, Dan; Koga, Dennis (Technical Monitor)
2001-01-01
Planetary rovers provide a considerable challenge for robotic systems in that they must operate for long periods autonomously, or with relatively little intervention. To achieve this, they need to have on-board fault detection and diagnosis capabilities in order to determine the actual state of the vehicle, and decide what actions are safe to perform. Traditional model-based diagnosis techniques are not suitable for rovers due to the tight coupling between the vehicle's performance and its environment. Hybrid diagnosis using particle filters is presented as an alternative, and its strengths and weakeners are examined. We also present some extensions to particle filters that are designed to make them more suitable for use in diagnosis problems.
NASA Astrophysics Data System (ADS)
Ren, Feixiang; Huang, Jinsheng; Terauchi, Mutsuhiro; Jiang, Ruyi; Klette, Reinhard
A robust and efficient lane detection system is an essential component of Lane Departure Warning Systems, which are commonly used in many vision-based Driver Assistance Systems (DAS) in intelligent transportation. Various computation platforms have been proposed in the past few years for the implementation of driver assistance systems (e.g., PC, laptop, integrated chips, PlayStation, and so on). In this paper, we propose a new platform for the implementation of lane detection, which is based on a mobile phone (the iPhone). Due to physical limitations of the iPhone w.r.t. memory and computing power, a simple and efficient lane detection algorithm using a Hough transform is developed and implemented on the iPhone, as existing algorithms developed based on the PC platform are not suitable for mobile phone devices (currently). Experiments of the lane detection algorithm are made both on PC and on iPhone.
Research on airborne infrared leakage detection of natural gas pipeline
NASA Astrophysics Data System (ADS)
Tan, Dongjie; Xu, Bin; Xu, Xu; Wang, Hongchao; Yu, Dongliang; Tian, Shengjie
2011-12-01
An airborne laser remote sensing technology is proposed to detect natural gas pipeline leakage in helicopter which carrying a detector, and the detector can detect a high spatial resolution of trace of methane on the ground. The principle of the airborne laser remote sensing system is based on tunable diode laser absorption spectroscopy (TDLAS). The system consists of an optical unit containing the laser, camera, helicopter mount, electronic unit with DGPS antenna, a notebook computer and a pilot monitor. And the system is mounted on a helicopter. The principle and the architecture of the airborne laser remote sensing system are presented. Field test experiments are carried out on West-East Natural Gas Pipeline of China, and the results show that airborne detection method is suitable for detecting gas leak of pipeline on plain, desert, hills but unfit for the area with large altitude diversification.
A multi-view face recognition system based on cascade face detector and improved Dlib
NASA Astrophysics Data System (ADS)
Zhou, Hongjun; Chen, Pei; Shen, Wei
2018-03-01
In this research, we present a framework for multi-view face detect and recognition system based on cascade face detector and improved Dlib. This method is aimed to solve the problems of low efficiency and low accuracy in multi-view face recognition, to build a multi-view face recognition system, and to discover a suitable monitoring scheme. For face detection, the cascade face detector is used to extracted the Haar-like feature from the training samples, and Haar-like feature is used to train a cascade classifier by combining Adaboost algorithm. Next, for face recognition, we proposed an improved distance model based on Dlib to improve the accuracy of multiview face recognition. Furthermore, we applied this proposed method into recognizing face images taken from different viewing directions, including horizontal view, overlooks view, and looking-up view, and researched a suitable monitoring scheme. This method works well for multi-view face recognition, and it is also simulated and tested, showing satisfactory experimental results.
Discreet passive explosive detection through 2-sided waveguided fluorescence
Harper, Ross James [Stillwater, OK; la Grone, Marcus [Cushing, OK; Fisher, Mark [Stillwater, OK
2011-10-18
The current invention provides a passive sampling device suitable for collecting and detecting the presence of target analytes. In particular, the passive sampling device is suitable for detecting nitro-aromatic compounds. The current invention further provides a passive sampling device reader suitable for determining the collection of target analytes. Additionally, the current invention provides methods for detecting target analytes using the passive sampling device and the passive sampling device reader.
Heightened sense for sensing: recent advances in pathogen immunoassay sensing platforms.
Fischer, Nicholas O; Tarasow, Theodore M; Tok, Jeffrey B-H
2007-03-01
Rapid and efficient sensors are essential for effective defense against the emerging threat of bioterrorism and biological warfare. This review article describes several recent immunosensing advances that are relevant to biothreat detection. These highly diverse examples are intended to demonstrate the breadth of these immunochemical sensing systems and platforms while highlighting those technologies that are suitable for pathogen detection.
Fast uncooled module 32×32 array of polycrystalline PbSe used for muzzle flash detection
NASA Astrophysics Data System (ADS)
Kastek, Mariusz; Dulski, Rafał; Trzaskawka, Piotr; Bieszczad, Grzegorz
2011-06-01
The paper presents some aspects of muzzle flash detection using low resolution polycrystalline PbSe uncooled 32×32 detectors array. This system for muzzle flash detection works in MWIR (3 - 5 microns) region and it is based on VPD (Vapor Phase Deposition) technology. The low density uncooled 32×32 array is suitable for being used in low cost IR imagers sensitive in the MWIR band with frame rates exceeding 1.000 Hz. The FPA detector, read-out electronics and processing electronics (allowing the implementation of some algorithms for muzzle flash detection) has been presented. The system has been tested at field test ground. Results of detection range measurement with two types of optical systems (wide and narrow field of view) have been shown. The initial results of testing of some algorithms for muzzle flash detection have been also presented.
Discreet passive explosive detection through 2-sided wave guided fluorescence
Harper, Ross James; la Grone, Marcus; Fisher, Mark
2012-10-16
The current invention provides a passive sampling device suitable for collecting and detecting the presence of target analytes. In particular, the passive sampling device is suitable for detecting nitro-aromatic compounds. The current invention further provides a passive sampling device reader suitable for determining the collection of target analytes. Additionally, the current invention provides methods for detecting target analytes using the passive sampling device and the passive sampling device reader.
Pino, Flavio; Ivandini, Tribidasari A; Nakata, Kazuya; Fujishima, Akira; Merkoçi, Arben; Einaga, Yasuaki
2015-01-01
A simple and reliable enzymatic system for organophosporus pesticide detection was successfully developed, by exploiting the synergy between the magnetic beads collection capacity and the outstanding electrochemistry property of boron-doped diamond electrodes. The determination of an organophosphate pesticide, chlorpyrifos (CPF), was performed based on the inhibition system of the enzyme acetylcholinesterase bonded to magnetic beads through a biotin-streptavidin complex system. A better sensitivity was found for a system with magnetic beads in the concentration range of 10(-9) to 10(-5) M. The estimated limits of detection based on IC10 (10% acetylcholinesterase (AChE) inhibition) have been detected and optimized to be 5.7 × 10(-10) M CPF. Spiked samples of water of Yokohama (Japan) have been measured to validate the efficiency of the enzymatic system. The results suggested that the use of magnetic beads to immobilize biomolecules or biosensing agents is suitable to maintain the superiority of BDD electrodes.
Retrieving hydrological connectivity from empirical causality in karst systems
NASA Astrophysics Data System (ADS)
Delforge, Damien; Vanclooster, Marnik; Van Camp, Michel; Poulain, Amaël; Watlet, Arnaud; Hallet, Vincent; Kaufmann, Olivier; Francis, Olivier
2017-04-01
Because of their complexity, karst systems exhibit nonlinear dynamics. Moreover, if one attempts to model a karst, the hidden behavior complicates the choice of the most suitable model. Therefore, both intense investigation methods and nonlinear data analysis are needed to reveal the underlying hydrological connectivity as a prior for a consistent physically based modelling approach. Convergent Cross Mapping (CCM), a recent method, promises to identify causal relationships between time series belonging to the same dynamical systems. The method is based on phase space reconstruction and is suitable for nonlinear dynamics. As an empirical causation detection method, it could be used to highlight the hidden complexity of a karst system by revealing its inner hydrological and dynamical connectivity. Hence, if one can link causal relationships to physical processes, the method should show great potential to support physically based model structure selection. We present the results of numerical experiments using karst model blocks combined in different structures to generate time series from actual rainfall series. CCM is applied between the time series to investigate if the empirical causation detection is consistent with the hydrological connectivity suggested by the karst model.
Evaluation of different heating methods for the detection of boar taint by means of the human nose.
Bekaert, K M; Aluwé, M; Vanhaecke, L; Heres, L; Duchateau, L; Vandendriessche, F; Tuyttens, F A M
2013-05-01
No automated detection system for boar taint detection is currently available, thus boar taint at the slaughterline can currently only be assessed using the singeing method (olfactory scoring). This study compares several heating methods (microwave, soldering iron and pyropen) and evaluates the effect of habituation, cleaning the soldering iron, singeing the fat twice in the same place, and variations in the technical procedures. All methods seem to be suitable for detecting boar taint but the choice of heating method for sensory scoring of boar taint depends on habituation of the trained assessor and specific conditions applied. The pyropen seems to be most suitable because it does not contact the fat and is easy to handle (wireless). Finally, the intensity score may also be influenced by: contamination from not cleaning the soldering iron, singeing the fat twice in the same place, and the effect of habituation. Copyright © 2013 Elsevier Ltd. All rights reserved.
PMD compensation in fiber-optic communication systems with direct detection using LDPC-coded OFDM.
Djordjevic, Ivan B
2007-04-02
The possibility of polarization-mode dispersion (PMD) compensation in fiber-optic communication systems with direct detection using a simple channel estimation technique and low-density parity-check (LDPC)-coded orthogonal frequency division multiplexing (OFDM) is demonstrated. It is shown that even for differential group delay (DGD) of 4/BW (BW is the OFDM signal bandwidth), the degradation due to the first-order PMD can be completely compensated for. Two classes of LDPC codes designed based on two different combinatorial objects (difference systems and product of combinatorial designs) suitable for use in PMD compensation are introduced.
Automated clinical system for chromosome analysis
NASA Technical Reports Server (NTRS)
Castleman, K. R.; Friedan, H. J.; Johnson, E. T.; Rennie, P. A.; Wall, R. J. (Inventor)
1978-01-01
An automatic chromosome analysis system is provided wherein a suitably prepared slide with chromosome spreads thereon is placed on the stage of an automated microscope. The automated microscope stage is computer operated to move the slide to enable detection of chromosome spreads on the slide. The X and Y location of each chromosome spread that is detected is stored. The computer measures the chromosomes in a spread, classifies them by group or by type and also prepares a digital karyotype image. The computer system can also prepare a patient report summarizing the result of the analysis and listing suspected abnormalities.
Monostatic ultra-wideband GPR antenna for through wall detection
NASA Astrophysics Data System (ADS)
Ali, Jawad; Abdullah, Noorsaliza; Yahya, Roshayati; Naeem, Taimoor
2017-11-01
The aim of this paper is to present a monostatic arc-shaped ultra-wideband (UWB) printed monopole antenna system with 3-16 GHz frequency bandwidth suitable for through-wall detection. Ground penetrating radar (GPR) technique is used for detection with the gain of 6.2 dB achieved for the proposed antenna using defected ground structure (DGS) method. To serve the purpose, a simulation experiment of through-wall detection model is constructed which consists of a monostatic antenna act as transmitter and receiver, concrete wall and human skin model. The time domain reflection of obtained result is then analysed for target detection.
Health management and controls for earth to orbit propulsion systems
NASA Technical Reports Server (NTRS)
Bickford, R. L.
1992-01-01
Fault detection and isolation for advanced rocket engine controllers are discussed focusing on advanced sensing systems and software which significantly improve component failure detection for engine safety and health management. Aerojet's Space Transportation Main Engine controller for the National Launch System is the state of the art in fault tolerant engine avionics. Health management systems provide high levels of automated fault coverage and significantly improve vehicle delivered reliability and lower preflight operations costs. Key technologies, including the sensor data validation algorithms and flight capable spectrometers, have been demonstrated in ground applications and are found to be suitable for bridging programs into flight applications.
Detecting unstable periodic orbits in chaotic time series using synchronization
NASA Astrophysics Data System (ADS)
Olyaei, Ali Azimi; Wu, Christine; Kinsner, Witold
2017-07-01
An alternative approach of detecting unstable periodic orbits in chaotic time series is proposed using synchronization techniques. A master-slave synchronization scheme is developed, in which the chaotic system drives a system of harmonic oscillators through a proper coupling condition. The proposed scheme is designed so that the power of the coupling signal exhibits notches that drop to zero once the system approaches an unstable orbit yielding an explicit indication of the presence of a periodic motion. The results shows that the proposed approach is particularly suitable in practical situations, where the time series is short and noisy, or it is obtained from high-dimensional chaotic systems.
The feasibility test of state-of-the-art face detection algorithms for vehicle occupant detection
NASA Astrophysics Data System (ADS)
Makrushin, Andrey; Dittmann, Jana; Vielhauer, Claus; Langnickel, Mirko; Kraetzer, Christian
2010-01-01
Vehicle seat occupancy detection systems are designed to prevent the deployment of airbags at unoccupied seats, thus avoiding the considerable cost imposed by the replacement of airbags. Occupancy detection can also improve passenger comfort, e.g. by activating air-conditioning systems. The most promising development perspectives are seen in optical sensing systems which have become cheaper and smaller in recent years. The most plausible way to check the seat occupancy by occupants is the detection of presence and location of heads, or more precisely, faces. This paper compares the detection performances of the three most commonly used and widely available face detection algorithms: Viola- Jones, Kienzle et al. and Nilsson et al. The main objective of this work is to identify whether one of these systems is suitable for use in a vehicle environment with variable and mostly non-uniform illumination conditions, and whether any one face detection system can be sufficient for seat occupancy detection. The evaluation of detection performance is based on a large database comprising 53,928 video frames containing proprietary data collected from 39 persons of both sexes and different ages and body height as well as different objects such as bags and rearward/forward facing child restraint systems.
Cai, Yicun; He, Yuping; Lv, Rong; Chen, Hongchao; Wang, Qiang; Pan, Liangwen
2017-01-01
Meat products often consist of meat from multiple animal species, and inaccurate food product adulteration and mislabeling can negatively affect consumers. Therefore, a cost-effective and reliable method for identification and quantification of animal species in meat products is required. In this study, we developed a duplex droplet digital PCR (dddPCR) detection and quantification system to simultaneously identify and quantify the source of meat in samples containing a mixture of beef (Bos taurus) and pork (Sus scrofa) in a single digital PCR reaction tube. Mixed meat samples of known composition were used to test the accuracy and applicability of this method. The limit of detection (LOD) and the limit of quantification (LOQ) of this detection and quantification system were also identified. We conclude that our dddPCR detection and quantification system is suitable for quality control and routine analyses of meat products.
Fischer, Melina; Schirrmeier, Horst; Wernike, Kerstin; Wegelt, Anne; Beer, Martin; Hoffmann, Bernd
2013-11-05
Schmallenberg virus (SBV), a novel orthobunyavirus of the Simbu serogroup, was first identified in October 2011 in dairy cattle in Germany, where it caused fever, diarrhea and a drop in milk yield. Since then, SBV additionally has been detected in adult sheep and goats. Although symptoms of acute infection were not observed, infection during a vulnerable phase of pregnancy caused congenital malformations and stillbirths. In view of the current situation and the possible emergence of further Simbu serogroup members, a pan-Simbu real-time reverse transcriptase (RT) PCR system for the reliable detection of Simbu serogroup viruses should be developed. In this study a pan-Simbu real-time RT-PCR system was established and compared to several SBV real-time RT-PCR assays. All PCR-systems were tested using a panel of different Simbu serogroup viruses as well as several field samples from diseased cattle, sheep and goats originating from all over Germany. Several pan-Simbu real-time RT-PCR products were sequenced via Sanger sequencing. Furthermore, in silico analyses were performed to investigate suitability for the detection of further orthobunyaviruses. All tested members of the Simbu serogroup (n = 14) as well as most of the field samples were successfully detected by the pan-Simbu real-time RT-PCR system. The comparison of this intercalating dye assay with different TaqMan probe-based assays developed for SBV diagnostics confirmed the functionality of the pan-Simbu assay for screening purposes. However, the SBV-TaqMan-assay SBV-S3 delivered the highest analytical sensitivity of less than ten copies per reaction for duplex systems including an internal control. In addition, for confirmation of SBV-genome detection the highly specific SBV-M1 assay was established. The pan-Simbu real-time RT-PCR system was able to detect all tested members of the Simbu serogroup, most of the SBV field samples as well as three tested Bunyamwera serogroup viruses with a suitable sensitivity. According to in silico analyses, this system seems to be able to detect a broad orthobunyavirus spectrum. As an additional feature of the pan-Simbu real-time RT-PCR system, subsequent species classification via sequencing is feasible. Regarding SBV diagnostics, the performance of the S-segment targeting SBV-S3 assay was superior with respect to the analytical sensitivity.
Research and applications of infrared thermal imaging systems suitable for developing countries
NASA Astrophysics Data System (ADS)
Weili, Zhang; Danyu, Cai
1986-01-01
It is a common situation in most developing countries that the utilization ratio of the sources of energy is low, the reliability service of equipment is poor, the cost of installation maintenance is high, the loss due to conflagration is heavy, and so on. Therefore, they are in urgent need of using infrared thermal imaging technique to improve their energy saving, equipment diagnosis as well as fire searching. But the infrared thermal imaging systems in the world market so far are not suitable for their use. This paper summarizes the research on two dimensional real time infrared thermal imaging systems on the basis of electron beam scanning and pyroelectric detection, as well as their applications in industry in China.
A Novel Online Data-Driven Algorithm for Detecting UAV Navigation Sensor Faults.
Sun, Rui; Cheng, Qi; Wang, Guanyu; Ochieng, Washington Yotto
2017-09-29
The use of Unmanned Aerial Vehicles (UAVs) has increased significantly in recent years. On-board integrated navigation sensors are a key component of UAVs' flight control systems and are essential for flight safety. In order to ensure flight safety, timely and effective navigation sensor fault detection capability is required. In this paper, a novel data-driven Adaptive Neuron Fuzzy Inference System (ANFIS)-based approach is presented for the detection of on-board navigation sensor faults in UAVs. Contrary to the classic UAV sensor fault detection algorithms, based on predefined or modelled faults, the proposed algorithm combines an online data training mechanism with the ANFIS-based decision system. The main advantages of this algorithm are that it allows real-time model-free residual analysis from Kalman Filter (KF) estimates and the ANFIS to build a reliable fault detection system. In addition, it allows fast and accurate detection of faults, which makes it suitable for real-time applications. Experimental results have demonstrated the effectiveness of the proposed fault detection method in terms of accuracy and misdetection rate.
Banada, Padmapriya P; Deshpande, Srinidhi; Chakravorty, Soumitesh; Russo, Riccardo; Occi, James; Meister, Gabriel; Jones, Kelly J; Gelhaus, Carl H; Valderas, Michelle W; Jones, Martin; Connell, Nancy; Alland, David
2017-01-01
Francisella tularensis is a potential bioterrorism agent that is highly infectious at very low doses. Diagnosis of tularemia by blood culture and nucleic acid-based diagnostic tests is insufficiently sensitive. Here, we demonstrate a highly sensitive F. tularensis assay that incorporates sample processing and detection into a single cartridge suitable for point-of-care detection. The assay limit of detection (LOD) and dynamic range were determined in a filter-based cartridge run on the GeneXpert system. F. tularensis DNA in buffer or CFU of F. tularensis was spiked into human or macaque blood. To simulate detection in human disease, the assay was tested on blood drawn from macaques infected with F. tularensis Schu S4 at daily intervals. Assay detection was compared to that with a conventional quantitative PCR (qPCR) assay and blood culture. The assay LOD was 0.1 genome equivalents (GE) per reaction and 10 CFU/ml F. tularensis in both human and macaque blood. In infected macaques, the assay detected F. tularensis on days 1 to 4 postinfection in 21%, 17%, 60%, and 83% of macaques, respectively, compared to conventional qPCR positivity rates of 0%, 0%, 30%, and 100% and CFU detection of blood culture at 0%, 0%, 0%, and 10% positive, respectively. Assay specificity was 100%. The new cartridge-based assay can rapidly detect F. tularensis in bloodstream infections directly in whole blood at the early stages of infection with a sensitivity that is superior to that of other methods. The simplicity of the automated testing procedures may make this test suitable for rapid point-of-care detection. Copyright © 2016 American Society for Microbiology.
Wei, Liping.; Doughan, Samer.; Han, Yi.; DaCosta, Matthew V.; Krull, Ulrich J.; Ho, Derek.
2014-01-01
Organic fluorophores and quantum dots are ubiquitous as contrast agents for bio-imaging and as labels in bioassays to enable the detection of biological targets and processes. Upconversion nanoparticles (UCNPs) offer a different set of opportunities as labels in bioassays and for bioimaging. UCNPs are excited at near-infrared (NIR) wavelengths where biological molecules are optically transparent, and their luminesce in the visible and ultraviolet (UV) wavelength range is suitable for detection using complementary metal-oxide-semiconductor (CMOS) technology. These nanoparticles provide multiple sharp emission bands, long lifetimes, tunable emission, high photostability, and low cytotoxicity, which render them particularly useful for bio-imaging applications and multiplexed bioassays. This paper surveys several key concepts surrounding upconversion nanoparticles and the systems that detect and process the corresponding luminescence signals. The principle of photon upconversion, tuning of emission wavelengths, UCNP bioassays, and UCNP time-resolved techniques are described. Electronic readout systems for signal detection and processing suitable for UCNP luminescence using CMOS technology are discussed. This includes recent progress in miniaturized detectors, integrated spectral sensing, and high-precision time-domain circuits. Emphasis is placed on the physical attributes of UCNPs that map strongly to the technical features that CMOS devices excel in delivering, exploring the interoperability between the two technologies. PMID:25211198
Mobile/android application for QRS detection using zero cross method
NASA Astrophysics Data System (ADS)
Rizqyawan, M. I.; Simbolon, A. I.; Suhendra, M. A.; Amri, M. F.; Kusumandari, D. E.
2018-03-01
In automatic ECG signal processing, one of the main topics of research is QRS complex detection. Detecting correct QRS complex or R peak is important since it is used to measure several other ECG metrics. One of the robust methods for QRS detection is Zero Cross method. This method uses an addition of high-frequency signal and zero crossing count to detect QRS complex which has a low-frequency oscillation. This paper presents an application of QRS detection using Zero Cross algorithm in the Android-based system. The performance of the algorithm in the mobile environment is measured. The result shows that this method is suitable for real-time QRS detection in a mobile application.
Computational methods for the control of distributed parameter systems
NASA Technical Reports Server (NTRS)
Burns, J. A.; Cliff, E. M.; Powers, R. K.
1985-01-01
It is shown that care must be taken to ensure that finite dimensional approximations of distributed parameter systems preserve important system properties (i.e., controllability, observability, stabilizability, detectability, etc.). It is noted that, if the particular scheme used to construct the finite dimensional model does not take into account these system properties, the model may not be suitable for control design and analysis. These ideas are illustrated by a simple example, i.e., a cable-spring-mass system.
Wang, Ophelia; Zachmann, Luke J; Sesnie, Steven E; Olsson, Aaryn D; Dickson, Brett G
2014-01-01
Prioritizing areas for management of non-native invasive plants is critical, as invasive plants can negatively impact plant community structure. Extensive and multi-jurisdictional inventories are essential to prioritize actions aimed at mitigating the impact of invasions and changes in disturbance regimes. However, previous work devoted little effort to devising sampling methods sufficient to assess the scope of multi-jurisdictional invasion over extensive areas. Here we describe a large-scale sampling design that used species occurrence data, habitat suitability models, and iterative and targeted sampling efforts to sample five species and satisfy two key management objectives: 1) detecting non-native invasive plants across previously unsampled gradients, and 2) characterizing the distribution of non-native invasive plants at landscape to regional scales. Habitat suitability models of five species were based on occurrence records and predictor variables derived from topography, precipitation, and remotely sensed data. We stratified and established field sampling locations according to predicted habitat suitability and phenological, substrate, and logistical constraints. Across previously unvisited areas, we detected at least one of our focal species on 77% of plots. In turn, we used detections from 2011 to improve habitat suitability models and sampling efforts in 2012, as well as additional spatial constraints to increase detections. These modifications resulted in a 96% detection rate at plots. The range of habitat suitability values that identified highly and less suitable habitats and their environmental conditions corresponded to field detections with mixed levels of agreement. Our study demonstrated that an iterative and targeted sampling framework can address sampling bias, reduce time costs, and increase detections. Other studies can extend the sampling framework to develop methods in other ecosystems to provide detection data. The sampling methods implemented here provide a meaningful tool when understanding the potential distribution and habitat of species over multi-jurisdictional and extensive areas is needed for achieving management objectives.
Wang, Ophelia; Zachmann, Luke J.; Sesnie, Steven E.; Olsson, Aaryn D.; Dickson, Brett G.
2014-01-01
Prioritizing areas for management of non-native invasive plants is critical, as invasive plants can negatively impact plant community structure. Extensive and multi-jurisdictional inventories are essential to prioritize actions aimed at mitigating the impact of invasions and changes in disturbance regimes. However, previous work devoted little effort to devising sampling methods sufficient to assess the scope of multi-jurisdictional invasion over extensive areas. Here we describe a large-scale sampling design that used species occurrence data, habitat suitability models, and iterative and targeted sampling efforts to sample five species and satisfy two key management objectives: 1) detecting non-native invasive plants across previously unsampled gradients, and 2) characterizing the distribution of non-native invasive plants at landscape to regional scales. Habitat suitability models of five species were based on occurrence records and predictor variables derived from topography, precipitation, and remotely sensed data. We stratified and established field sampling locations according to predicted habitat suitability and phenological, substrate, and logistical constraints. Across previously unvisited areas, we detected at least one of our focal species on 77% of plots. In turn, we used detections from 2011 to improve habitat suitability models and sampling efforts in 2012, as well as additional spatial constraints to increase detections. These modifications resulted in a 96% detection rate at plots. The range of habitat suitability values that identified highly and less suitable habitats and their environmental conditions corresponded to field detections with mixed levels of agreement. Our study demonstrated that an iterative and targeted sampling framework can address sampling bias, reduce time costs, and increase detections. Other studies can extend the sampling framework to develop methods in other ecosystems to provide detection data. The sampling methods implemented here provide a meaningful tool when understanding the potential distribution and habitat of species over multi-jurisdictional and extensive areas is needed for achieving management objectives. PMID:25019621
Ambulatory instrumentation suitable for long-term monitoring of cattle health.
Schoenig, S A; Hildreth, T S; Nagl, L; Erickson, H; Spire, M; Andresen, D; Warren, S
2004-01-01
The benefits of real-time health diagnoses of cattle are potentially tremendous. Early detection of transmissible disease, whether from natural or terrorist events, could help to avoid huge financial losses in the agriculture industry while also improving meat quality. This work discusses physiological and behavioral parameters relevant to cattle state-of-health assessment. These parameters, along with a potentially harsh monitoring environment, drive a set of design considerations that must be addressed when building systems to acquire long-term, real-time measurements in the field. A prototype system is presented that supports the measurement of suitable physiologic parameters and begins to address the design constraints for continuous state-of-health determination in free-roaming cattle.
Radiation detector based on a matrix of crossed wavelength-shifting fibers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kross, Brian J.; Weisenberger, Andrew; Zorn, Carl
A radiation detection system comprising a detection grid of wavelength shifting fibers with a volume of scintillating material at the intersecting points of the fibers. Light detectors, preferably Silicon Photomultipliers, are positioned at the ends of the fibers. The position of radiation is determined from data obtained from the detection grid. The system is easily scalable, customizable, and also suitable for use in soil and underground applications. An alternate embodiment employs a fiber grid sheet or layer which is comprised of multiple fibers secured to one another within the same plane. This embodiment further includes shielding in order to preventmore » radiation cross-talk within the grid layer.« less
Detection of gait characteristics for scene registration in video surveillance system.
Havasi, László; Szlávik, Zoltán; Szirányi, Tamás
2007-02-01
This paper presents a robust walk-detection algorithm, based on our symmetry approach which can be used to extract gait characteristics from video-image sequences. To obtain a useful descriptor of a walking person, we temporally track the symmetries of a person's legs. Our method is suitable for use in indoor or outdoor surveillance scenes. Determining the leading leg of the walking subject is important, and the presented method can identify this from two successive walk steps (one walk cycle). We tested the accuracy of the presented walk-detection method in a possible application: Image registration methods are presented which are applicable to multicamera systems viewing human subjects in motion.
NASA Technical Reports Server (NTRS)
Hoge, F. E.; Swift, R. N.; Yungel, J. K.
1983-01-01
The present investigation provides a demonstration of the feasibility of the airborne detection of the laser-induced fluorescence spectral emissions from living terrestrial grasses, shrubs, and trees using existing levels of lidar technology. Airborne studies were performed to ascertain system requirements necessary to detect laser-induced fluorescence from living terrestrial plants, to assess the practical acquisition of useful single-shot laser-induced fluorescence (LIF) waveforms over vegetative canopies, and to determine the comparative suitability of laser system, airborne platform, and terrestrial environmental parameters. The field experiment was conducted on May 3, 1982, over the northern portion of Wallops Island, VA. Attention is given to airborne lidar results and the description of laboratory investigations.
Highly Sensitive Tunable Diode Laser Spectrometers for In Situ Planetary Exploration
NASA Technical Reports Server (NTRS)
Vasudev, Ram; Mansour, Kamjou; Webster, Christopher R.
2013-01-01
This paper describes highly sensitive tunable diode laser spectrometers suitable for in situ planetary exploration. The technology developed at JPL is based on wavelength modulated cavity enhanced absorption spectroscopy. It is capable of sensitively detecting chemical signatures of life through the abundance of biogenic molecules and their isotopic composition, and chemicals such as water necessary for habitats of life. The technology would be suitable for searching for biomarkers, extinct life, potential habitats of extant life, and signatures of ancient climates on Mars; and for detecting biomarkers, prebiotic chemicals and habitats of life in the outer Solar System. It would be useful for prospecting for water on the Moon and asteroids, and characterizing its isotopic composition. Deployment on the Moon could provide ground truth to the recent remote measurements and help to uncover precious records of the early bombardment history of the inner Solar System buried at the shadowed poles, and elucidate the mechanism for the generation of near-surface water in the illuminated regions. The technology would also be useful for detecting other volatile molecules in planetary atmospheres and subsurface reservoirs, isotopic characterization of planetary materials, and searching for signatures of extinct life preserved in solid matrices.
Motion detection and compensation in infrared retinal image sequences.
Scharcanski, J; Schardosim, L R; Santos, D; Stuchi, A
2013-01-01
Infrared image data captured by non-mydriatic digital retinography systems often are used in the diagnosis and treatment of the diabetic macular edema (DME). Infrared illumination is less aggressive to the patient retina, and retinal studies can be carried out without pupil dilation. However, sequences of infrared eye fundus images of static scenes, tend to present pixel intensity fluctuations in time, and noisy and background illumination changes pose a challenge to most motion detection methods proposed in the literature. In this paper, we present a retinal motion detection method that is adaptive to background noise and illumination changes. Our experimental results indicate that this method is suitable for detecting retinal motion in infrared image sequences, and compensate the detected motion, which is relevant in retinal laser treatment systems for DME. Copyright © 2013 Elsevier Ltd. All rights reserved.
Tewari, S N; Harpalani, S P
1977-01-11
The toxicological analysis of 12 common organophosphorus insecticides is described. Suitable methods for the extraction of organophosphorus insecticides from tissues are proposed. The detection, identification and estimation of these insecticides by thin-layer chromatography is described for 25 solvent systems and a series of chromogenic reagents. The distribution of insecticides in human body tissues in five cases of poisoning by ethyl parathion, malathion, dimethoate, sumithion and phosphamidon has also been studied.
NASA Astrophysics Data System (ADS)
Yazdandoust, Fatemeh; Tatenguem Fankem, Hervé; Milde, Tobias; Jimenez, Alvaro; Sacher, Joachim
2018-02-01
We report the development of a platform, based-on a Field-Programmable Gate Arrays (FPGAs) and suitable for Time-Division-Multiplexed DFB lasers. The designed platform is subsequently combined with a spectroscopy setup, for detection and quantification of species in a gas mixture. The experimental results show a detection limit of 460 ppm, an uncertainty of 0.1% and a computation time of less than 1000 clock cycles. The proposed system offers a high level of flexibility and is applicable to arbitrary types of gas-mixtures.
Research on moving object detection based on frog's eyes
NASA Astrophysics Data System (ADS)
Fu, Hongwei; Li, Dongguang; Zhang, Xinyuan
2008-12-01
On the basis of object's information processing mechanism with frog's eyes, this paper discussed a bionic detection technology which suitable for object's information processing based on frog's vision. First, the bionics detection theory by imitating frog vision is established, it is an parallel processing mechanism which including pick-up and pretreatment of object's information, parallel separating of digital image, parallel processing, and information synthesis. The computer vision detection system is described to detect moving objects which has special color, special shape, the experiment indicates that it can scheme out the detecting result in the certain interfered background can be detected. A moving objects detection electro-model by imitating biologic vision based on frog's eyes is established, the video simulative signal is digital firstly in this system, then the digital signal is parallel separated by FPGA. IN the parallel processing, the video information can be caught, processed and displayed in the same time, the information fusion is taken by DSP HPI ports, in order to transmit the data which processed by DSP. This system can watch the bigger visual field and get higher image resolution than ordinary monitor systems. In summary, simulative experiments for edge detection of moving object with canny algorithm based on this system indicate that this system can detect the edge of moving objects in real time, the feasibility of bionic model was fully demonstrated in the engineering system, and it laid a solid foundation for the future study of detection technology by imitating biologic vision.
Kepler Mission to Detect Earth-like Planets
NASA Technical Reports Server (NTRS)
Kondo, Yoji
2003-01-01
Kepler Mission to detect Earth-like planets in our Milky Way galaxy was approved by NASA in December 2001 for a 4-5 year mission. The launch is planned in about 5 years. The Kepler observatory will be placed in an Earth-trailing orbit. The unique feature of the Kepler Mission is its ability to detect Earth-like planets orbiting around solar-type stars at a distance similar to that of Earth (from our Sun); such an orbit could provide an environment suitable for supporting life as we know it. The Kepler observatory accomplishes this feat by looking for the transits of planetary object in front of their suns; Kepler has a photometric precision of 10E-5 (0.00001) to achieve such detections. Other ongoing planetary detection programs (based mostly on a technique that looks for the shifting of spectral lines of the primary star due to its planetary companions' motions around it) have detected massive planets (with masses in the range of Jupiter); such massive planets are not considered suitable for supporting life. If our current theories for the formation of planetary systems are valid, we expect to detect about 50 Earth-like planets during Kepler's 4-year mission (assuming a random distribution of the planetary orbital inclinations with respect to the line of sight from Kepler). The number of detection will increase about 640 planets if the planets to be detected are Jupiter-sized.
Kepler Mission to Detect Earth-like Planets
NASA Technical Reports Server (NTRS)
Kondo, Yoji
2002-01-01
Kepler Mission to detect Earth-like planets in our Milky Way galaxy was approved by NASA in December 2001 for a 4-5 year mission. The launch is planned in about 5 years. The Kepler observatory will be placed in an Earth-trailing orbit. The unique feature of the Kepler Mission is its ability to detect Earth-like planets orbiting around solar-type stars at a distance similar to that of Earth (from our Sun); such an orbit could provide an environment suitable for supporting life as we know it. The Kepler observatory accomplishes this feat by looking for the transits of planetary object in front of their suns; Kepler has a photometric precision of 10E-5 (0.00001) to achieve such detections. Other ongoing planetary detection programs (based mostly on a technique that looks for the shifting of spectral lines of the primary star due to its planetary companions' motions around it) have detected massive planets (with masses in the range of Jupiter); such massive planets are not considered suitable for supporting life. If our current theories for the formation of planetary systems are valid, we expect to detect about 50 Earth-like planets during Kepler's 4-year mission (assuming a random distribution of the planetary orbital inclinations with respect to the line of sight from Kepler). The number of detection will increase about 640 planets if the planets to be detected are Jupiter-sized.
Faverjon, C; Vial, F; Andersson, M G; Lecollinet, S; Leblond, A
2017-04-01
West Nile virus (WNV) is a growing public health concern in Europe and there is a need to develop more efficient early detection systems. Nervous signs in horses are considered to be an early indicator of WNV and, using them in a syndromic surveillance system, might be relevant. In our study, we assessed whether or not data collected by the passive French surveillance system for the surveillance of equine diseases can be used routinely for the detection of WNV. We tested several pre-processing methods and detection algorithms based on regression. We evaluated system performances using simulated and authentic data and compared them to those of the surveillance system currently in place. Our results show that the current detection algorithm provided similar performances to those tested using simulated and real data. However, regression models can be easily and better adapted to surveillance objectives. The detection performances obtained were compatible with the early detection of WNV outbreaks in France (i.e. sensitivity 98%, specificity >94%, timeliness 2·5 weeks and around four false alarms per year) but further work is needed to determine the most suitable alarm threshold for WNV surveillance in France using cost-efficiency analysis.
2016-01-01
Passive content fingerprinting is widely used for video content identification and monitoring. However, many challenges remain unsolved especially for partial-copies detection. The main challenge is to find the right balance between the computational cost of fingerprint extraction and fingerprint dimension, without compromising detection performance against various attacks (robustness). Fast video detection performance is desirable in several modern applications, for instance, in those where video detection involves the use of large video databases or in applications requiring real-time video detection of partial copies, a process whose difficulty increases when videos suffer severe transformations. In this context, conventional fingerprinting methods are not fully suitable to cope with the attacks and transformations mentioned before, either because the robustness of these methods is not enough or because their execution time is very high, where the time bottleneck is commonly found in the fingerprint extraction and matching operations. Motivated by these issues, in this work we propose a content fingerprinting method based on the extraction of a set of independent binary global and local fingerprints. Although these features are robust against common video transformations, their combination is more discriminant against severe video transformations such as signal processing attacks, geometric transformations and temporal and spatial desynchronization. Additionally, we use an efficient multilevel filtering system accelerating the processes of fingerprint extraction and matching. This multilevel filtering system helps to rapidly identify potential similar video copies upon which the fingerprint process is carried out only, thus saving computational time. We tested with datasets of real copied videos, and the results show how our method outperforms state-of-the-art methods regarding detection scores. Furthermore, the granularity of our method makes it suitable for partial-copy detection; that is, by processing only short segments of 1 second length. PMID:27861492
NASA Astrophysics Data System (ADS)
Kastek, Mariusz; PiÄ tkowski, Tadeusz; Polakowski, Henryk; Barela, Jaroslaw; Firmanty, Krzysztof; Trzaskawka, Piotr; Vergara, German; Linares, Rodrigo; Gutierrez, Raul; Fernandez, Carlos; Montojo Supervielle, Maria Teresa
2014-05-01
The paper presents some aspects of muzzle flash detection using low resolution polycrystalline PbSe 32×32 and 80×80 detectors FPA operating at room temperature (uncooled performance). These sensors, which detect in MWIR (3 - 5 microns region) and are manufactured using proprietary technology from New Infrared Technologies (VPD PbSe - Vapor Phase Deposition of polycrystalline PbSe), can be applied to muzzle flash detection. The system based in the uncooled 80×80 FPA monolithically integrated with the CMOS readout circuitry has allowed image recording with frame rates over 2000 Hz (true snapshot acquisition), whereas the lower density, uncooled 32×32 FPA is suitable for being used in low cost infrared imagers sensitive in the MWIR band with frame rates above 1000 Hz. The FPA detector, read-out electronics and processing electronics (allows the implementation of some algorithms for muzzle flash detection) of both systems are presented. The systems have been tested at field test ground. Results of detection range measurement with two types of optical systems (wide and narrow field of view) have been shown. The theoretical analysis of possibility detection of muzzle flash and initial results of testing of some algorithms for muzzle flash detection have been presented too.
Knuttinen, M-G; Parrish, T B; Weiss, C; LaBar, K S; Gitelman, D R; Power, J M; Mesulam, M-M; Disterhoft, J F
2002-10-01
This study was designed to develop a suitable method of recording eyeblink responses while conducting functional magnetic resonance imaging (fMRI). Given the complexity of this behavioral setup outside of the magnet, this study sought to adapt and further optimize an approach to eyeblink conditioning that would be suitable for conducting event-related fMRI experiments. This method involved the acquisition of electromyographic (EMG) signals from the orbicularis oculi of the right eye, which were subsequently amplified and converted into an optical signal outside of the head coil. This optical signal was converted back into an electrical signal once outside the magnet room. Electromyography (EMG)-detected eyeblinks were used to measure responses in a delay eyeblink conditioning paradigm. Our results indicate that: (1) electromyography is a sensitive method for the detection of eyeblinks during fMRI; (2) minimal interactions or artifacts of the EMG signal were created from the magnetic resonance pulse sequence; and (3) no electromyography-related artifacts were detected in the magnetic resonance images. Furthermore, an analysis of the functional data showed areas of activation that have previously been shown in positron emission tomography studies of human eyeblink conditioning. Our results support the strength of this behavioral setup as a suitable method to be used in association with fMRI.
Automated seizure detection systems and their effectiveness for each type of seizure.
Ulate-Campos, A; Coughlin, F; Gaínza-Lein, M; Fernández, I Sánchez; Pearl, P L; Loddenkemper, T
2016-08-01
Epilepsy affects almost 1% of the population and most of the approximately 20-30% of patients with refractory epilepsy have one or more seizures per month. Seizure detection devices allow an objective assessment of seizure frequency and a treatment tailored to the individual patient. A rapid recognition and treatment of seizures through closed-loop systems could potentially decrease morbidity and mortality in epilepsy. However, no single detection device can detect all seizure types. Therefore, the choice of a seizure detection device should consider the patient-specific seizure semiologies. This review of the literature evaluates seizure detection devices and their effectiveness for different seizure types. Our aim is to summarize current evidence, offer suggestions on how to select the most suitable seizure detection device for each patient and provide guidance to physicians, families and researchers when choosing or designing seizure detection devices. Further, this review will guide future prospective validation studies. Copyright © 2016. Published by Elsevier Ltd.
Vehicle tracking using fuzzy-based vehicle detection window with adaptive parameters
NASA Astrophysics Data System (ADS)
Chitsobhuk, Orachat; Kasemsiri, Watjanapong; Glomglome, Sorayut; Lapamonpinyo, Pipatphon
2018-04-01
In this paper, fuzzy-based vehicle tracking system is proposed. The proposed system consists of two main processes: vehicle detection and vehicle tracking. In the first process, the Gradient-based Adaptive Threshold Estimation (GATE) algorithm is adopted to provide the suitable threshold value for the sobel edge detection. The estimated threshold can be adapted to the changes of diverse illumination conditions throughout the day. This leads to greater vehicle detection performance compared to a fixed user's defined threshold. In the second process, this paper proposes the novel vehicle tracking algorithms namely Fuzzy-based Vehicle Analysis (FBA) in order to reduce the false estimation of the vehicle tracking caused by uneven edges of the large vehicles and vehicle changing lanes. The proposed FBA algorithm employs the average edge density and the Horizontal Moving Edge Detection (HMED) algorithm to alleviate those problems by adopting fuzzy rule-based algorithms to rectify the vehicle tracking. The experimental results demonstrate that the proposed system provides the high accuracy of vehicle detection about 98.22%. In addition, it also offers the low false detection rates about 3.92%.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Wenfang; Du, Jinjin; Wen, Ruijuan
We have investigated the transmission spectra of a Fabry-Perot interferometer (FPI) with squeezed vacuum state injection and non-Gaussian detection, including photon number resolving detection and parity detection. In order to show the suitability of the system, parallel studies were made of the performance of two other light sources: coherent state of light and Fock state of light either with classical mean intensity detection or with non-Gaussian detection. This shows that by using the squeezed vacuum state and non-Gaussian detection simultaneously, the resolution of the FPI can go far beyond the cavity standard bandwidth limit based on the current techniques. Themore » sensitivity of the scheme has also been explored and it shows that the minimum detectable sensitivity is better than that of the other schemes.« less
Consistent detection and identification of individuals in a large camera network
NASA Astrophysics Data System (ADS)
Colombo, Alberto; Leung, Valerie; Orwell, James; Velastin, Sergio A.
2007-10-01
In the wake of an increasing number of terrorist attacks, counter-terrorism measures are now a main focus of many research programmes. An important issue for the police is the ability to track individuals and groups reliably through underground stations, and in the case of post-event analysis, to be able to ascertain whether specific individuals have been at the station previously. While there exist many motion detection and tracking algorithms, the reliable deployment of them in a large network is still ongoing research. Specifically, to track individuals through multiple views, on multiple levels and between levels, consistent detection and labelling of individuals is crucial. In view of these issues, we have developed a change detection algorithm to work reliably in the presence of periodic movements, e.g. escalators and scrolling advertisements, as well as a content-based retrieval technique for identification. The change detection technique automatically extracts periodically varying elements in the scene using Fourier analysis, and constructs a Markov model for the process. Training is performed online, and no manual intervention is required, making this system suitable for deployment in large networks. Experiments on real data shows significant improvement over existing techniques. The content-based retrieval technique uses MPEG-7 descriptors to identify individuals. Given the environment under which the system operates, i.e. at relatively low resolution, this approach is suitable for short timescales. For longer timescales, other forms of identification such as gait, or if the resolution allows, face recognition, will be required.
NASA Technical Reports Server (NTRS)
Senturia, S. D.
1977-01-01
Polymer responses to a variety of smouldering sources, including cellulose, acrylic, urethane, polyvinyl chloride, and wool were investigated. A suitable trapping system for combustion products was developed and a charge flow transistor was fabricated to monitor the transverse or sheet resistance of a thin film.
Oversight of this investigation will be provided by the U.S. Environmental Protection Agency through the Environmental Technology Verification (ETV) Program. This project will be performed by Battelle, which manages the ETV Advanced Monitoring Systems (AMS) Center through a coop...
Lin, Cheng; Zhu, Yong; Wei, Wei; Zhang, Jie; Tian, Li; Xu, Zu-Wen
2013-05-01
An all-optical quartz-enhanced photoacoustic spectroscopy system, based on the F-P demodulation, for trace gas detection in the open environment was proposed. In quartz-enhanced photoacoustic spectroscopy (QEPAS), an optical fiber Fabry-Perot method was used to replace the conventional electronic demodulation method. The photoacoustic signal was obtained by demodulating the variation of the Fabry-Perot cavity between the quartz tuning fork side and the fiber face. An experimental system was setup. The experiment for detection of water vapour in the open environment was carried on. A normalized noise equivalent absorption coefficient of 2.80 x 10(-7) cm(-1) x W x Hz(-1/2) was achieved. The result demonstrated that the sensitivity of the all-optical quartz-enhanced photoacoustic spectroscopy system is about 2.6 times higher than that of the conventional QEPAS system. The all-optical quartz-enhanced photoacoustic spectroscopy system is immune to electromagnetic interference, safe in flammable and explosive gas detection, suitable for high temperature and high humidity environments and realizable for long distance, multi-point and network sensing.
Evaluation of a novel chemical sensor system to detect clinical mastitis in bovine milk.
Mottram, Toby; Rudnitskaya, Alisa; Legin, Andrey; Fitzpatrick, Julie L; Eckersall, P David
2007-05-15
Automatic detection of clinical mastitis is an essential part of high performance and robotic milking. Currently available technology (conductivity monitoring) is unable to achieve acceptable specificity or sensitivity of detection of clinical mastitis or other clinical diseases. Arrays of sensors with high cross-sensitivity have been successfully applied for recognition and quantitative analysis of other multicomponent liquids. An experiment was conducted to determine whether a multisensor system ("electronic tongue") based on an array of chemical sensors and suitable data processing could be used to discriminate between milk secretions from infected and healthy glands. Measurements were made with a multisensor system of milk samples from two different farms in two experiments. A total of 67 samples of milk from both mastitic and healthy glands were in two sets. It was demonstrated that the multisensor system could distinguish between control and clinically mastitic milk samples (p=0.05). The sensitivity and specificity of the sensor system (93 and 96% correspondingly) showed an improvement over conductivity (56 and 82% correspondingly). The multisensor system offers a novel method of improving mastitis detection.
Chun, Honggu; Dennis, Patty J; Ferguson Welch, Erin R; Alarie, Jean Pierre; Jorgenson, James W; Ramsey, J Michael
2017-11-10
The development and application of polyelectrolytic gel electrodes (PGEs) for a microfluidic photothermal absorbance detection system is described. The PGEs are used to measure changes in conductivity based on heat generation by analytes absorbing light and changing the solution viscosity. The PGEs are suitable for direct contact conductivity measurements since they do not degrade with exposure to high electric fields. Both a 2-electrode system with DC voltages and a 3-electrode system with AC voltages were investigated. Experimental factors including excitation voltage, excitation frequency, laser modulation frequency, laser power, and path length were tested. The limits of detection for the 3-electrode and 2-electrode systems are 500nM and 0.55nM for DABSYL-tagged glucosamine, respectively. In addition, an electrokinetic separation of a potassium, DABSYL-tagged glucosamine, Rhodamine 6G, and Rhodamine B mixture was demonstrated. Copyright © 2017 Elsevier B.V. All rights reserved.
Forlenza, Lidia; Carton, Patrick; Accardo, Domenico; Fasano, Giancarmine; Moccia, Antonio
2012-01-01
This paper describes the target detection algorithm for the image processor of a vision-based system that is installed onboard an unmanned helicopter. It has been developed in the framework of a project of the French national aerospace research center Office National d’Etudes et de Recherches Aérospatiales (ONERA) which aims at developing an air-to-ground target tracking mission in an unknown urban environment. In particular, the image processor must detect targets and estimate ground motion in proximity of the detected target position. Concerning the target detection function, the analysis has dealt with realizing a corner detection algorithm and selecting the best choices in terms of edge detection methods, filtering size and type and the more suitable criterion of detection of the points of interest in order to obtain a very fast algorithm which fulfills the computation load requirements. The compared criteria are the Harris-Stephen and the Shi-Tomasi, ones, which are the most widely used in literature among those based on intensity. Experimental results which illustrate the performance of the developed algorithm and demonstrate that the detection time is fully compliant with the requirements of the real-time system are discussed. PMID:22368499
A high-throughput method for GMO multi-detection using a microfluidic dynamic array.
Brod, Fábio Cristiano Angonesi; van Dijk, Jeroen P; Voorhuijzen, Marleen M; Dinon, Andréia Zilio; Guimarães, Luis Henrique S; Scholtens, Ingrid M J; Arisi, Ana Carolina Maisonnave; Kok, Esther J
2014-02-01
The ever-increasing production of genetically modified crops generates a demand for high-throughput DNA-based methods for the enforcement of genetically modified organisms (GMO) labelling requirements. The application of standard real-time PCR will become increasingly costly with the growth of the number of GMOs that is potentially present in an individual sample. The present work presents the results of an innovative approach in genetically modified crops analysis by DNA based methods, which is the use of a microfluidic dynamic array as a high throughput multi-detection system. In order to evaluate the system, six test samples with an increasing degree of complexity were prepared, preamplified and subsequently analysed in the Fluidigm system. Twenty-eight assays targeting different DNA elements, GM events and species-specific reference genes were used in the experiment. The large majority of the assays tested presented expected results. The power of low level detection was assessed and elements present at concentrations as low as 0.06 % were successfully detected. The approach proposed in this work presents the Fluidigm system as a suitable and promising platform for GMO multi-detection.
Design of remote control alarm system by microwave detection
NASA Astrophysics Data System (ADS)
Wang, Junli
2018-04-01
A microwave detection remote control alarm system is designed, which is composed of a Microwave detectors, a radio receiving/transmitting module and a digital encoding/decoding IC. When some objects move into the surveillance area, microwave detectors will generate a control signal to start transmitting system. A radio control signal will be spread by the transmitting module, once the signal can be received, and it will be disposed by some circuits, arousing some voices that awake the watching people. The whole device is a modular configuration, it not only has some advantage of frequency stable, but also reliable and adjustment-free, and it is suitable for many kinds of demands within the distance of 100m.
Elliott, Jonathan T; Dsouza, Alisha V; Marra, Kayla; Pogue, Brian W; Roberts, David W; Paulsen, Keith D
2016-09-01
Fluorescence guided surgery has the potential to positively impact surgical oncology; current operating microscopes and stand-alone imaging systems are too insensitive or too cumbersome to maximally take advantage of new tumor-specific agents developed through the microdose pathway. To this end, a custom-built illumination and imaging module enabling picomolar-sensitive near-infrared fluorescence imaging on a commercial operating microscope is described. The limits of detection and system specifications are characterized, and in vivo efficacy of the system in detecting ABY-029 is evaluated in a rat orthotopic glioma model following microdose injections, showing the suitability of the device for microdose phase 0 clinical trials.
Dsouza, Alisha V.; Marra, Kayla; Pogue, Brian W.; Roberts, David W.; Paulsen, Keith D.
2016-01-01
Fluorescence guided surgery has the potential to positively impact surgical oncology; current operating microscopes and stand-alone imaging systems are too insensitive or too cumbersome to maximally take advantage of new tumor-specific agents developed through the microdose pathway. To this end, a custom-built illumination and imaging module enabling picomolar-sensitive near-infrared fluorescence imaging on a commercial operating microscope is described. The limits of detection and system specifications are characterized, and in vivo efficacy of the system in detecting ABY-029 is evaluated in a rat orthotopic glioma model following microdose injections, showing the suitability of the device for microdose phase 0 clinical trials. PMID:27699098
Characterization of fluid flow by digital correlation of scattered light
NASA Technical Reports Server (NTRS)
Gilbert, John A.; Matthys, Donald R.
1989-01-01
The objective is to produce a physical system suitable for a space environment that can measure fluid velocities in a three-dimensional volume by the development of a particle correlation velocimetry technique. Experimental studies were conducted on a field test cell to demonstrate the suitability and accuracy of digital correlation techniques for measuring two-dimensional fluid flows. This objective was satisfied by: (1) the design of an appropriate illumination and detection system for making velocity measurements within a test cell; (2) the design and construction of a test cell; (3) the preliminary evaluations on fluid and seeding requirements; and (4) the performance of controlled tests using a multiple exposure correlation technique. This presentation is represented by viewgraphs with very little text.
Development of the MOOSY4 eNose IoT for Sulphur-Based VOC Water Pollution Detection
Climent, Enric; Pelegri-Sebastia, Jose; Sogorb, Tomas; Talens, J. B.; Chilo, Jose
2017-01-01
In this paper, we describe a new low-cost and portable electronic nose instrument, the Multisensory Odor Olfactory System MOOSY4. This prototype is based on only four metal oxide semiconductor (MOS) gas sensors suitable for IoT technology. The system architecture consists of four stages: data acquisition, data storage, data processing, and user interfacing. The designed eNose was tested with experiment for detection of volatile components in water pollution, as a dimethyl disulphide or dimethyl diselenide or sulphur. Therefore, the results provide evidence that odor information can be recognized with around 86% efficiency, detecting smells unwanted in the water and improving the quality control in bottled water factories. PMID:28825645
Truong, Thi Ngoc Lien; Tran, Dai Lam; Vu, Thi Hong An; Tran, Vinh Hoang; Duong, Tuan Quang; Dinh, Quang Khieu; Tsukahara, Toshifumi; Lee, Young Hoon; Kim, Jong Seung
2010-01-15
In this paper, we describe DNA electrochemical detection for genetically modified organism (GMO) based on multi-wall carbon nanotubes (MWCNTs)-doped polypyrrole (PPy). DNA hybridization is studied by quartz crystal microbalance (QCM) and electrochemical impedance spectroscopy (EIS). An increase in DNA complementary target concentration results in a decrease in the faradic charge transfer resistance (R(ct)) and signifying "signal-on" behavior of MWCNTs-PPy-DNA system. QCM and EIS data indicated that the electroanalytical MWCNTs-PPy films were highly sensitive (as low as 4pM of target can be detected with QCM technique). In principle, this system can be suitable not only for DNA but also for protein biosensor construction.
Permeation absorption sampler with multiple detection
Zaromb, Solomon
1990-01-01
A system for detecting analytes in air or aqueous systems includes a permeation absorption preconcentrator sampler for the analytes and analyte detectors. The preconcentrator has an inner fluid-permeable container into which a charge of analyte-sorbing liquid is intermittently injected, and a fluid-impermeable outer container. The sample is passed through the outer container and around the inner container for trapping and preconcentrating the analyte in the sorbing liquid. The analyte can be detected photometrically by injecting with the sorbing material a reagent which reacts with the analyte to produce a characteristic color or fluorescence which is detected by illuminating the contents of the inner container with a light source and measuring the absorbed or emitted light, or by producing a characteristic chemiluminescence which can be detected by a suitable light sensor. The analyte can also be detected amperometrically. Multiple inner containers may be provided into which a plurality of sorbing liquids are respectively introduced for simultaneously detecting different analytes. Baffles may be provided in the outer container. A calibration technique is disclosed.
Preliminary study of the use of radiotracers for leak detection in industrial applications
NASA Astrophysics Data System (ADS)
Wetchagarun, S.; Petchrak, A.; Tippayakul, C.
2015-05-01
One of the most widespread uses of radiotracers in the industrial applications is the leak detection of the systems. This technique can be applied, for example, to detect leak in heat exchangers or along buried industrial pipelines. The ability to perform online investigation is one of the most important advantages of the radiotracer technique over other non-radioactive leak detection methods. In this paper, a preliminary study of the leak detection using radiotracer in the laboratory scale was presented. Br-82 was selected for this work due to its chemical property, its suitable half-life and its on-site availability. The NH4Br in the form of aqueous solution was injected into the experimental system as the radiotracer. Three NaI detectors were placed along the pipelines to measure system flow rate and to detect the leakage from the piping system. The results obtained from the radiotracer technique were compared to those measured by other methods. It is found that the flow rate obtained from the radiotracer technique agreed well with the one obtained from the flow meter. The leak rate result, however, showed discrepancy between results obtained from two different measuring methods indicating further study on leak detection was required before applying this technique in the industrial system.
Adaptation of a military FTS to civilian air toxics measurements
DOE Office of Scientific and Technical Information (OSTI.GOV)
Engel, J.R.; Dorval, R.K.
1994-12-31
In many ways, the military problem of chemical agent detection is similar to the civilian problem of toxic and related air pollutants detection. A recent program to design a next generation Fourier transform spectrometer (FTS) based chemical agent detection system has been funded by the US Army. This program has resulted in an FTS system that has a number of characteristics that make it suitable for applications to the civilian measurement problem. Low power, low weight, and small size lead to low installation, operating and maintenance costs. Innovative use of diode lasers in place of HeNe reference sources leads tomore » long lifetimes and high reliability. Absolute scan position servos allow for highly efficient offset scanning. This paper will relate the performance of this system to present air monitoring requirements.« less
Rapid detection of Escherichia coli O157:H7 using tunneling magnetoresistance biosensor
NASA Astrophysics Data System (ADS)
Wu, Yuanzhao; Liu, Yiwei; Zhan, Qingfeng; Liu, J. Ping; Li, Run-Wei
2017-05-01
A rapid method for the sensitive detection of bacteria using magnetic immunoassay, which are measured with a tunneling magnetoresistance (TMR) sensor, is described. For the measurement of Escherichia coli O157:H7 (E. coli O157:H7) bacteria, the target was labeled by magnetic beads through magnetic immunoassay. The magnetic beads produce a weak magnetic fringe field when external field is applied, thus induce the magnetoresistance change of TMR sensor. A detection limit of 100 CFU/mL E. coli O157:H7 bacteria in 5 hours was obtained. With its high sensitive and rapid detection scheme based on the TMR biosensor, the detection system is an excellent candidate suitable and promising for food safety and biomedical detection.
Laser-self-mixing interferometry for mechatronics applications.
Ottonelli, Simona; Dabbicco, Maurizio; De Lucia, Francesco; di Vietro, Michela; Scamarcio, Gaetano
2009-01-01
We report on the development of an all-interferometric optomechatronic sensor for the detection of multi-degrees-of-freedom displacements of a remote target. The prototype system exploits the self-mixing technique and consists only of a laser head, equipped with six laser sources, and a suitably designed reflective target. The feasibility of the system was validated experimentally for both single or multi-degrees-of-freedom measurements, thus demonstrating a simple and inexpensive alternative to costly and bulky existing systems.
Programmable near-infrared ranging system
Everett, Jr., Hobart R.
1989-01-01
A high angular resolution ranging system particularly suitable for indoor plications involving mobile robot navigation and collision avoidance uses a programmable array of light emitters that can be sequentially incremented by a microprocessor. A plurality of adjustable level threshold detectors are used in an optical receiver for detecting the threshold level of the light echoes produced when light emitted from one or more of the emitters is reflected by a target or object in the scan path of the ranging system.
Design of Advanced Atmospheric Water Vapor Differential Absorption Lidar (DIAL) Detection System
NASA Technical Reports Server (NTRS)
Refaat, Tamer F.; Luck, William S., Jr.; DeYoung, Russell J.
1999-01-01
The measurement of atmospheric water vapor is very important for understanding the Earth's climate and water cycle. The lidar atmospheric sensing experiment (LASE) is an instrument designed and operated by the Langley Research Center for high precision water vapor measurements. The design details of a new water vapor lidar detection system that improves the measurement sensitivity of the LASE instrument by a factor of 10 are discussed. The new system consists of an advanced, very low noise, avalanche photodiode (APD) and a state-of-the-art signal processing circuit. The new low-power system is also compact and lightweight so that it would be suitable for space flight and unpiloted atmospheric vehicles (UAV) applications. The whole system is contained on one small printed circuit board (9 x 15 sq cm). The detection system is mounted at the focal plane of a lidar receiver telescope, and the digital output is read by a personal computer with a digital data acquisition card.
NASA Astrophysics Data System (ADS)
Liu, Maw-Yang; Hsu, Yi-Kai
2017-03-01
Three-arm dual-balanced detection scheme is studied in an optical code division multiple access system. As the MAI and beat noise are the main deleterious source of system performance, we utilize optical hard-limiters to alleviate such channel impairment. In addition, once the channel condition is improved effectively, the proposed two-dimensional error correction code can remarkably enhance the system performance. In our proposed scheme, the optimal thresholds of optical hard-limiters and decision circuitry are fixed, and they will not change with other system parameters. Our proposed scheme can accommodate a large number of users simultaneously and is suitable for burst traffic with asynchronous transmission. Therefore, it is highly recommended as the platform for broadband optical access network.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xu, J; Sisniega, A; Zbijewski, W
Purpose: To design a dedicated x-ray cone-beam CT (CBCT) system suitable to deployment at the point-of-care and offering reliable detection of acute intracranial hemorrhage (ICH), traumatic brain injury (TBI), stroke, and other head and neck injuries. Methods: A comprehensive task-based image quality model was developed to guide system design and optimization of a prototype head scanner suitable to imaging of acute TBI and ICH. Previously reported models were expanded to include the effects of x-ray scatter correction necessary for detection of low contrast ICH and the contribution of bit depth (digitization noise) to imaging performance. Task-based detectablity index provided themore » objective function for optimization of system geometry, x-ray source, detector type, anti-scatter grid, and technique at 10–25 mGy dose. Optimal characteristics were experimentally validated using a custom head phantom with 50 HU contrast ICH inserts imaged on a CBCT imaging bench allowing variation of system geometry, focal spot size, detector, grid selection, and x-ray technique. Results: The model guided selection of system geometry with a nominal source-detector distance 1100 mm and optimal magnification of 1.50. Focal spot size ∼0.6 mm was sufficient for spatial resolution requirements in ICH detection. Imaging at 90 kVp yielded the best tradeoff between noise and contrast. The model provided quantitation of tradeoffs between flat-panel and CMOS detectors with respect to electronic noise, field of view, and readout speed required for imaging of ICH. An anti-scatter grid was shown to provide modest benefit in conjunction with post-acquisition scatter correction. Images of the head phantom demonstrate visualization of millimeter-scale simulated ICH. Conclusions: Performance consistent with acute TBI and ICH detection is feasible with model-based system design and robust artifact correction in a dedicated head CBCT system. Further improvements can be achieved with incorporation of model-based iterative reconstruction techniques also within the scope of the task-based optimization framework. David Foos and Xiaohui Wang are employees of Carestream Health.« less
An endogenous reference gene of common and durum wheat for detection of genetically modified wheat.
Imai, Shinjiro; Tanaka, Keiko; Nishitsuji, Yasuyuki; Kikuchi, Yosuke; Matsuoka, Yasuyuki; Arami, Shin-Ichiro; Sato, Megumi; Haraguchi, Hiroyuki; Kurimoto, Youichi; Mano, Junichi; Furui, Satoshi; Kitta, Kazumi
2012-01-01
To develop a method for detecting GM wheat that may be marketed in the near future, we evaluated the proline-rich protein (PRP) gene as an endogenous reference gene of common wheat (Triticum aestivum L.) and durum wheat (Triticum durum L.). Real-time PCR analysis showed that only DNA of wheat was amplified and no amplification product was observed for phylogenetically related cereals, indicating that the PRP detection system is specific to wheat. The intensities of the amplification products and Ct values among all wheat samples used in this study were very similar, with no nonspecific or additional amplification, indicating that the PRP detection system has high sequence stability. The limit of detection was estimated at 5 haploid genome copies. The PRP region was demonstrated to be present as a single or double copy in the common wheat haploid genome. Furthermore, the PRP detection system showed a highly linear relationship between Ct values and the amount of plasmid DNA, indicating that an appropriate calibration curve could be constructed for quantitative detection of GM wheat. All these results indicate that the PRP gene is a suitable endogenous reference gene for PCR-based detection of GM wheat.
Rear-end vision-based collision detection system for motorcyclists
NASA Astrophysics Data System (ADS)
Muzammel, Muhammad; Yusoff, Mohd Zuki; Meriaudeau, Fabrice
2017-05-01
In many countries, the motorcyclist fatality rate is much higher than that of other vehicle drivers. Among many other factors, motorcycle rear-end collisions are also contributing to these biker fatalities. To increase the safety of motorcyclists and minimize their road fatalities, this paper introduces a vision-based rear-end collision detection system. The binary road detection scheme contributes significantly to reduce the negative false detections and helps to achieve reliable results even though shadows and different lane markers are present on the road. The methodology is based on Harris corner detection and Hough transform. To validate this methodology, two types of dataset are used: (1) self-recorded datasets (obtained by placing a camera at the rear end of a motorcycle) and (2) online datasets (recorded by placing a camera at the front of a car). This method achieved 95.1% accuracy for the self-recorded dataset and gives reliable results for the rear-end vehicle detections under different road scenarios. This technique also performs better for the online car datasets. The proposed technique's high detection accuracy using a monocular vision camera coupled with its low computational complexity makes it a suitable candidate for a motorbike rear-end collision detection system.
Optical detection system for MEMS-type pressure sensor
NASA Astrophysics Data System (ADS)
Sareło, K.; Górecka-Drzazga, A.; Dziuban, J. A.
2015-07-01
In this paper a special optical detection system designed for a MEMS-type (micro-electro-mechanical system) silicon pressure sensor is presented. The main part of the optical system—a detection unit with a perforated membrane—is bonded to the silicon sensor, and placed in a measuring system. An external light source illuminates the membrane of the pressure sensor. Owing to the light reflected from the deflected membrane sensor, the optical pattern consisting of light points is visible, and pressure can be estimated. The optical detection unit (20 × 20 × 20.4 mm3) is fabricated using microengineering techniques. Its dimensions are adjusted to the dimensions of the pressure sensor (5 × 5 mm2 silicon membrane). Preliminary tests of the optical detection unit integrated with the silicon pressure sensor are carried out. For the membrane sensor from 15 to 60 µm thick, a repeatable detection of the differential pressure in the range of 0 to 280 kPa is achieved. The presented optical microsystem is especially suitable for the pressure measurements in a high radiation environment.
NASA Astrophysics Data System (ADS)
McStay, D.; McIlroy, J.; Forte, A.; Lunney, F.; Greenway, T.; Thabeth, K.; Dean, G.
2005-06-01
A new 2000 m depth rated subsea sensor that can effectively, rapidly and remotely detect leaks of fluorescein dye, leak detection chemicals and hydraulic fluids from underwater structures is reported. The system utilizes ultra-bright LED technology to project a structured beam of light, at a wavelength suitable to excite the fluorescence of the target material, into the water column. The resultant fluorescence is collected and digital signal processing used to extract the intensity. The system is capable of detecting ppm concentrations of fluorescein at a range of 2.5 m in water in real time. The ability to stand-off from subsea structures, while rapidly detecting the chemicals makes the system highly suited to subsea leak inspections with remotely operated vehicles or autonomous underwater vehicles, as it allows the vehicles to be flown quickly and safely over the structure to be inspected. This increases both the speed and effectiveness of the inspection. The remote detection capability is also highly effective for probing complex underwater structures. The system has been successfully used in real subsea survey applications and has been found to be effective, user friendly and to dramatically reduce inspection times and hence costs.
Kim, Hanah; Hur, Mina; Kim, Ji Young; Moon, Hee Won; Yun, Yeo Min; Cho, Hyun Chan
2017-03-01
Cytomegalovirus (CMV) and Epstein-Barr virus (EBV) are increasingly important in immunocompromised patients. Nucleic acid extraction methods could affect the results of viral nucleic acid amplification tests. We compared two automated nucleic acid extraction systems for detecting CMV and EBV using real-time PCR assays. One hundred and fifty-three whole blood (WB) samples were tested for CMV detection, and 117 WB samples were tested for EBV detection. Viral nucleic acid was extracted in parallel by using QIAsymphony RGQ and QIAcube (Qiagen GmbH, Germany), and real-time PCR assays for CMV and EBV were performed with a Rotor-Gene Q real-time PCR cycler (Qiagen). Detection rates for CMV and EBV were compared, and agreements between the two systems were analyzed. The detection rate of CMV and EBV differed significantly between the QIAsymphony RGQ and QIAcube systems (CMV, 59.5% [91/153] vs 43.8% [67/153], P=0.0005; EBV, 59.0% [69/117] vs 42.7% [50/117], P=0.0008). The two systems showed moderate agreement for CMV and EBV detection (kappa=0.43 and 0.52, respectively). QIAsymphony RGQ showed a negligible correlation with QIAcube for quantitative EBV detection. QIAcube exhibited EBV PCR inhibition in 23.9% (28/117) of samples. Automated nucleic acid extraction systems have different performances and significantly affect the detection of viral pathogens. The QIAsymphony RGQ system appears to be superior to the QIAcube system for detecting CMV and EBV. A suitable sample preparation system should be considered for optimized nucleic acid amplification in clinical laboratories.
Enzyme activity in terrestrial soil in relation to exploration of the Martian surface
NASA Technical Reports Server (NTRS)
Ardakani, M. S.; Mclaren, A. D.; Pukite, A. H.
1972-01-01
An exploration was made of enzyme activities in soil, including abundance, persistence and localization of these activities. An attempt was made to develop procedures for the detection and assaying of enzymes in soils suitable for presumptive tests for life in planetary soils. A suitable extraction procedure for soil enzymes was developed and measurements were made of activities in extracts in order to study how urease is complexed in soil organic matter. Mathematical models were developed, based on enzyme action and microbial growth in soil, for rates of oxidation of nitrogen as nitrogen compounds are moved downward in soil by water flow. These biogeochemical models should be applicable to any percolating system, with suitable modification for special features, such as oxygen concetrations, and types of hydrodynamic flow.
15 CFR 700.71 - Audits and investigations.
Code of Federal Regulations, 2011 CFR
2011-01-01
... interviews and a systems evaluation to detect problems or failures in the implementation of this regulation... personally. Personal service may also be made by leaving a copy of the document with someone of suitable age... personal service is made, the individual making the service shall prepare an affidavit as to the manner in...
[Application of the mixed programming with Labview and Matlab in biomedical signal analysis].
Yu, Lu; Zhang, Yongde; Sha, Xianzheng
2011-01-01
This paper introduces the method of mixed programming with Labview and Matlab, and applies this method in a pulse wave pre-processing and feature detecting system. The method has been proved suitable, efficient and accurate, which has provided a new kind of approach for biomedical signal analysis.
Portable Holographic Interferometry Testing System: Application to crack patching quality control
DOE Office of Scientific and Technical Information (OSTI.GOV)
Heslehurst, R.B.; Baird, J.P.; Williamson, H.M.
Over recent years the repair of metallic structures has been improved through the use of patches fabricated from composite materials and adhesively bonded to the damaged area. This technology is termed crack patching, and has been successfully and extensively used by the RAAF and the USAF. However, application of the technology to civilian registered aircraft has had limited success due to the apparent lack of suitable quality assurance testing methods and the airworthiness regulators concern overpatch adhesion integrity. Holographic interferometry has previously shown the advantages of detecting out-of-plane deformations of the order of the wavelength of light (1{mu}). Evidence willmore » be presented that holography is able to detect changes in load path due to debonds and weakened adhesion in an adhesively bonded patch. A Portable Holographic Interferometry Testing System (PHITS) which overcomes the vibration isolation problem associated with conventional holography techniques has been developed. The application of PHITS to crack patching technology now provides a suitable method to verify the integrity of bonded patches in-situ.« less
Kim, Yoonjung; Han, Mi-Soon; Kim, Juwon; Kwon, Aerin; Lee, Kyung-A
2014-01-01
A total of 84 nasopharyngeal swab specimens were collected from 84 patients. Viral nucleic acid was extracted by three automated extraction systems: QIAcube (Qiagen, Germany), EZ1 Advanced XL (Qiagen), and MICROLAB Nimbus IVD (Hamilton, USA). Fourteen RNA viruses and two DNA viruses were detected using the Anyplex II RV16 Detection kit (Seegene, Republic of Korea). The EZ1 Advanced XL system demonstrated the best analytical sensitivity for all the three viral strains. The nucleic acids extracted by EZ1 Advanced XL showed higher positive rates for virus detection than the others. Meanwhile, the MICROLAB Nimbus IVD system was comprised of fully automated steps from nucleic extraction to PCR setup function that could reduce human errors. For the nucleic acids recovered from nasopharyngeal swab specimens, the QIAcube system showed the fewest false negative results and the best concordance rate, and it may be more suitable for detecting various viruses including RNA and DNA virus strains. Each system showed different sensitivity and specificity for detection of certain viral pathogens and demonstrated different characteristics such as turnaround time and sample capacity. Therefore, these factors should be considered when new nucleic acid extraction systems are introduced to the laboratory.
Detection of Rare Antimicrobial Resistance Profiles by Active and Passive Surveillance Approaches
Mather, Alison E.; Reeve, Richard; Mellor, Dominic J.; Matthews, Louise; Reid-Smith, Richard J.; Haydon, Daniel T.; Reid, Stuart W. J.
2016-01-01
Antimicrobial resistance (AMR) surveillance systems are generally not specifically designed to detect emerging resistances and usually focus primarily on resistance to individual drugs. Evaluating the diversity of resistance, using ecological metrics, allows the assessment of sampling protocols with regard to the detection of rare phenotypes, comprising combinations of resistances. Surveillance data of phenotypic AMR of Canadian poultry Salmonella Heidelberg and swine Salmonella Typhimurium var. 5- were used to contrast active (representative isolates derived from healthy animals) and passive (diagnostic isolates) surveillance and assess their suitability for detecting emerging resistance patterns. Although in both datasets the prevalences of resistance to individual antimicrobials were not significantly different between the two surveillance systems, analysis of the diversity of entire resistance phenotypes demonstrated that passive surveillance of diagnostic isolates detected more unique phenotypes. Whilst the most appropriate surveillance method will depend on the relevant objectives, under the conditions of this study, passive surveillance of diagnostic isolates was more effective for the detection of rare and therefore potentially emerging resistance phenotypes. PMID:27391966
NASA Technical Reports Server (NTRS)
Cleary, T.; Grosshandler, W.
1999-01-01
As part of the National Aeronautics and Space Administration (NASA) initiated program on global civil aviation, NIST is assisting Federal Aviation Administration in its research to improve fire detection in aircraft cargo compartments. Aircraft cargo compartment detection certification methods have been reviewed. The Fire Emulator-Detector Evaluator (FE/DE) has been designed to evaluate fire detection technologies such as new sensors, multi-element detectors, and detectors that employ complex algorithms. The FE/DE is a flow tunnel that can reproduce velocity, temperature, smoke, and Combustion gas levels to which a detector might be exposed during a fire. A scientific literature survey and patent search have been conducted relating to existing and emerging fire detection technologies, and the potential use of new fire detection strategies in cargo compartment areas has been assessed. In the near term, improved detector signal processing and multi-sensor detectors based on combinations of smoke measurements, combustion gases and temperature are envisioned as significantly impacting detector system performance.
Generation of a CW local oscillator signal using a stabilized injection locked semiconductor laser
NASA Astrophysics Data System (ADS)
Pezeshki, Jonah Massih
In high speed-communications, it is desirable to be able to detect small signals while maintaining a low bit-error rate. Conventional receivers for high-speed fiber optic networks are Amplified Direct Detectors (ADDs) that use erbium-doped fiber amplifiers (EDFAs) before the detector to achieve a suitable sensitivity. In principle, a better method for obtaining the maximum possible signal to noise ratio is through the use of homodyne detection. The major difficulty in implementing a homodyne detection system is the generation of a suitable local oscillator signal. This local oscillator signal must be at the same frequency as the received data signal, as well as be phase coherent with it. To accomplish this, a variety of synchronization techniques have been explored, including Optical Phase-Lock Loops (OPLL), Optical Injection Locking (OIL) with both Fabry-Perot and DFB lasers, and an Optical Injection Phase-Lock Loop (OIPLL). For this project I have implemented a method for regenerating a local oscillator from a portion of the received optical signal. This regenerated local oscillator is at the same frequency, and is phase coherent with, the received optical signal. In addition, we show that the injection locking process can be electronically stabilized by using the modulation transfer ratio of the slave laser as a monitor, given either a DFB or Fabry-Perot slave laser. We show that this stabilization technique maintains injection lock (given a locking range of ˜1GHz) for laser drift much greater than what is expected in a typical transmission system. In addition, we explore the quality of the output of the slave laser, and analyze its suitability as a local oscillator signal for a homodyne receiver.
Chandrasekaran, Arvind; Packirisamy, Muthukumaran
2009-01-01
The advent of microoptoelectromechanical systems (MOEMS) and its integration with other technologies such as microfluidics, microthermal, immunoproteomics, etc. has led to the concept of an integrated micro-total-analysis systems (microTAS) or Lab-on-a-Chip for chemical and biological applications. Recently, research and development of microTAS have attained a significant growth rate over several biodetection sciences, in situ medical diagnoses, and point-of-care testing applications. However, it is essential to develop suitable biophysical label-free detection methods for the success, reliability, and ease of use of the microTAS. We proposed an infrared (IR)-based evanescence wave detection system on the silicon-on-insulator platform for biodetection with microTAS. The system operates on the principle of bio-optical interaction that occurs due to the evanescence of light from the waveguide device. The feasibility of biodetection has been experimentally investigated by the detection of horse radish peroxidase upon its reaction with hydrogen peroxide.
Ishihara, Toshihiro; Kobayashi, Tatsushi; Ikeno, Naoya; Hayashi, Takayuki; Sakakibara, Masahiro; Niki, Noboru; Satake, Mitsuo; Moriyama, Noriyuki
2014-01-01
To refine the development and evaluate the near-infrared (NIR) extravasation detection system and its ability to detect extravasation during a contrast-enhanced computed tomography (CT) examination. The NIR extravasation detection system projects the NIR light through the surface of the human skin then, using its sensory system, will monitor the changes in the amount of NIR that reflected, which varies based on absorption properties.Seven female pigs were used to evaluate the contrast media extravasation detection system, using a 20-gauge intravenous catheter, when injected at a rate of 1 mL/s into 4 different locations just under the skin in the thigh section. Using 3-dimensional CT images, we evaluated the extravasations between time and volume, depth and volume, and finally depth and time to detect. We confirmed that the NIR light, 950-nm wavelength, used by the extravasation detection system is well absorbed by contrast media, making changes easy to detect. The average time to detect an extravasation was 2.05 seconds at a depth of 2.0 mm below the skin with a volume of 1.3 mL, 2.57 seconds at a depth between 2.1 and 5 mm below the skin and a volume of 3.47 mL, 10.5 seconds for depths greater than 5.1 mm and a volume of 11.1 mL. The detection accuracy was significantly deteriorated when the depth exceeded 5.0 mm (Tukey-Kramer, P < 0.05) CONCLUSIONS: The extravasation system detection system that is using NIR has a high level of detection sensitivity. The sensitivity enables the system to detect extravasation at depths less than 2 mm with a volume of 1.5 mL and at depths less than 5 mm with a volume of 3.5 mL. The extravasation detection system could be suitable for use during examinations.
Laser-Self-Mixing Interferometry for Mechatronics Applications
Ottonelli, Simona; Dabbicco, Maurizio; De Lucia, Francesco; di Vietro, Michela; Scamarcio, Gaetano
2009-01-01
We report on the development of an all-interferometric optomechatronic sensor for the detection of multi-degrees-of-freedom displacements of a remote target. The prototype system exploits the self-mixing technique and consists only of a laser head, equipped with six laser sources, and a suitably designed reflective target. The feasibility of the system was validated experimentally for both single or multi-degrees-of-freedom measurements, thus demonstrating a simple and inexpensive alternative to costly and bulky existing systems. PMID:22412324
Song, Yonghai; Chen, Jingyi; Liu, Hongyu; Li, Ping; Li, Hongbo; Wang, Li
2015-09-03
A simple, sensitive and effective method to detect glucose in ultra-low ionic strength solution containing citrate-capped silver nanoparticles (CCAgNPs) was developed by monitoring the change of solution conductance. Glucose was catalyzed into gluconic acid firstly by glucose oxidase in an O2-saturated solution accompanied by the reduction of O2 into hydrogen peroxide (H2O2). Then, CCAgNPs was oxidized by H2O2 into Ag(+) and the capping regent of citrate was released at the same time. All these resulted Ag(+), gluconic acid and the released citrate would contribute to the increase of solution ionic strength together, leading to a detectable increase of solution conductance. And a novel conductance glucose biosensor was developed with a routine linear range of 0.06-4.0 mM and a suitable detection limit of 18.0 μM. The novel glucose biosensor was further applied in energy drink sample and proven to be suitable for practical system with low ionic strength. The proposed conductance biosensor achieved a significant breakthrough of glucose detection in ultra-low ionic strength media. Copyright © 2015 Elsevier B.V. All rights reserved.
On the SAR derived alert in the detection of oil spills according to the analysis of the EGEMP.
Ferraro, Guido; Baschek, Björn; de Montpellier, Geraldine; Njoten, Ove; Perkovic, Marko; Vespe, Michele
2010-01-01
Satellite services that deliver information about possible oil spills at sea currently use different labels of "confidence" to describe the detections based on radar image processing. A common approach is to use a classification differentiating between low, medium and high levels of confidence. There is an ongoing discussion on the suitability of the existing classification systems of possible oil spills detected by radar satellite images with regard to the relevant significance and correspondence to user requirements. This paper contains a basic analysis of user requirements, current technical possibilities of satellite services as well as proposals for a redesign of the classification system as an evolution towards a more structured alert system. This research work offers a first review of implemented methodologies for the categorisation of detected oil spills, together with the proposal of explorative ideas evaluated by the European Group of Experts on satellite Monitoring of sea-based oil Pollution (EGEMP). Copyright 2009 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Julich, S.; Kopinč, R.; Hlawatsch, N.; Moche, C.; Lapanje, A.; Gärtner, C.; Tomaso, H.
2014-05-01
Lab-on-a-chip systems are innovative tools for the detection and identification of microbial pathogens in human and veterinary medicine. The major advantages are small sample volume and a compact design. Several fluidic modules have been developed to transform analytical procedures into miniaturized scale including sampling, sample preparation, target enrichment, and detection procedures. We present evaluation data for single modules that will be integrated in a chip system for the detection of pathogens. A microfluidic chip for purification of nucleic acids was established for cell lysis using magnetic beads. This assay was evaluated with spiked environmental aerosol and swab samples. Bacillus thuringiensis was used as simulant for Bacillus anthracis, which is closely related but non-pathogenic for humans. Stationary PCR and a flow-through PCR chip module were investigated for specific detection of six highly pathogenic bacteria. The conventional PCR assays could be transferred into miniaturized scale using the same temperature/time profile. We could demonstrate that the microfluidic chip modules are suitable for the respective purposes and are promising tools for the detection of bacterial pathogens. Future developments will focus on the integration of these separate modules to an entire lab-on-a-chip system.
Structural monitoring for rare events in remote locations
NASA Astrophysics Data System (ADS)
Hale, J. M.
2005-01-01
A structural monitoring system has been developed for use on high value engineering structures, which is particularly suitable for use in remote locations where rare events such as accidental impacts, seismic activity or terrorist attack might otherwise go undetected. The system comprises a low power intelligent on-site data logger and a remote analysis computer that communicate with one another using the internet and mobile telephone technology. The analysis computer also generates e-mail alarms and maintains a web page that displays detected events in near real-time to authorised users. The application of the prototype system to pipeline monitoring is described in which the analysis of detected events is used to differentiate between impacts and pressure surges. The system has been demonstrated successfully and is ready for deployment.
Hendriks, Jan; Stojanovic, Ivan; Schasfoort, Richard B M; Saris, Daniël B F; Karperien, Marcel
2018-06-05
There is a large unmet need for reliable biomarker measurement systems for clinical application. Such systems should meet challenging requirements for large scale use, including a large dynamic detection range, multiplexing capacity, and both high specificity and sensitivity. More importantly, these requirements need to apply to complex biological samples, which require extensive quality control. In this paper, we present the development of an enhancement detection cascade for surface plasmon resonance imaging (SPRi). The cascade applies an antibody sandwich assay, followed by neutravidin and a gold nanoparticle enhancement for quantitative biomarker measurements in small volumes of complex fluids. We present a feasibility study both in simple buffers and in spiked equine synovial fluid with four cytokines, IL-1β, IL-6, IFN-γ, and TNF-α. Our enhancement cascade leads to an antibody dependent improvement in sensitivity up to 40 000 times, resulting in a limit of detection as low as 50 fg/mL and a dynamic detection range of more than 7 logs. Additionally, measurements at these low concentrations are highly reliable with intra- and interassay CVs between 2% and 20%. We subsequently showed this assay is suitable for multiplex measurements with good specificity and limited cross-reactivity. Moreover, we demonstrated robust detection of IL-6 and IL-1β in spiked undiluted equine synovial fluid with small variation compared to buffer controls. In addition, the availability of real time measurements provides extensive quality control opportunities, essential for clinical applications. Therefore, we consider this method is suitable for broad application in SPRi for multiplex biomarker detection in both research and clinical settings.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Youssef, Tarek; El Hariri, Mohammad; Habib, Hani
Abstract— Secure high-speed communication is required to ensure proper operation of complex power grid systems and prevent malicious tampering activities. In this paper, artificial neural networks with temporal dependency are introduced for false data identification and mitigation for broadcasted IEC 61850 SMV messages. The fast responses of such intelligent modules in intrusion detection make them suitable for time- critical applications, such as protection. However, care must be taken in selecting the appropriate intelligence model and decision criteria. As such, this paper presents a customizable malware script to sniff and manipulate SMV messages and demonstrates the ability of the malware tomore » trigger false positives in the neural network’s response. The malware developed is intended to be as a vaccine to harden the intrusion detection system against data manipulation attacks by enhancing the neural network’s ability to learn and adapt to these attacks.« less
NASA Astrophysics Data System (ADS)
Ashiba, Hiroki; Fujimaki, Makoto; Awazu, Koichi; Fu, Mengying; Ohki, Yoshimichi; Tanaka, Torahiko; Makishima, Makoto
2016-02-01
Hemagglutination is utilized for various immunological assays, including blood typing and virus detection. Herein, we describe a method of rapid hemagglutination detection based on a microfluidic channel installed on an optical waveguide-mode sensor. Human blood samples mixed with hemagglutinating antibodies associated with different blood groups were injected into the microfluidic channel, and reflectance spectra of the samples were measured after stopping the flow. The agglutinated and nonagglutinated samples were distinguishable by the alterations in their reflectance spectra with time; the microfluidic channels worked as spatial restraints for agglutinated red blood cells. The demonstrated system allowed rapid hemagglutination detection within 1 min. The suitable height of the channels was also discussed.
Advanced Earth Observation System Instrumentation Study (AEOSIS)
NASA Technical Reports Server (NTRS)
Var, R. E.
1976-01-01
The feasibility, practicality, and cost are investigated for establishing a national system or grid of artificial landmarks suitable for automated (near real time) recognition in the multispectral scanner imagery data from an earth observation satellite (EOS). The intended use of such landmarks, for orbit determination and improved mapping accuracy is reviewed. The desirability of using xenon searchlight landmarks for this purpose is explored theoretically and by means of experimental results obtained with LANDSAT 1 and LANDSAT 2. These results are used, in conjunction with the demonstrated efficiency of an automated detection scheme, to determine the size and cost of a xenon searchlight that would be suitable for an EOS Searchlight Landmark Station (SLS), and to facilitate the development of a conceptual design for an automated and environmentally protected EOS SLS.
A portable detection system for in vivo monitoring of 131I in routine and emergency situations
NASA Astrophysics Data System (ADS)
Lucena, EA; Dantas, ALA; Dantas, BM
2018-03-01
In vivo monitoring of 131I in human thyroid is often used to evaluate occupational exposure in nuclear medicine facilities and in the case of accidental intakes in nuclear power plants for the monitoring of workers and population. The device presented in this work consists on a Pb-collimated NaI(Tl)3”x3” scintillation detector assembled on a tripod and connected to a portable PC. The evaluation of the applicability and limitations of the system is based on the estimation of the committed effective doses associated to the minimum detectable activities in different facilities. It has been demonstrated that the system is suitable for use in routine and accidental situations.
Stereoroentgenographic System With Portable Calibration Cage For Use In Clinical Medicine
NASA Astrophysics Data System (ADS)
Moffitt, Francis; Baumrind, Sheldon; Chafetz, Neil; Curry, Sean
1983-07-01
For the past five years, we have been accumulating information on the performance of a stereoroentgenographic system developed for use in clinical medicine and first reported at the NATO Symposium on the Application of Human Biostereometrics. This system represents an adaptation of normal case coplanar stereometry and involves the use of a single emitter which is displaced in a controlled fashion between exposures. The system has been used primarily for the detection of applicance loosening and settling following the placement of total hip protheses and also for the detection of pseudorthosis following lumbo-sacral fusion. One major goal has been the development of a data acquisition and analysis system suitable for general hospital use which can be operated by technicians without specialized photogrammetric training. This report will focus on system design and on the delineation of technical problems encountered during routine clinical use of the system.
Gradual cut detection using low-level vision for digital video
NASA Astrophysics Data System (ADS)
Lee, Jae-Hyun; Choi, Yeun-Sung; Jang, Ok-bae
1996-09-01
Digital video computing and organization is one of the important issues in multimedia system, signal compression, or database. Video should be segmented into shots to be used for identification and indexing. This approach requires a suitable method to automatically locate cut points in order to separate shot in a video. Automatic cut detection to isolate shots in a video has received considerable attention due to many practical applications; our video database, browsing, authoring system, retrieval and movie. Previous studies are based on a set of difference mechanisms and they measured the content changes between video frames. But they could not detect more special effects which include dissolve, wipe, fade-in, fade-out, and structured flashing. In this paper, a new cut detection method for gradual transition based on computer vision techniques is proposed. And then, experimental results applied to commercial video are presented and evaluated.
Health management and controls for Earth-to-orbit propulsion systems
NASA Astrophysics Data System (ADS)
Bickford, R. L.
1995-03-01
Avionics and health management technologies increase the safety and reliability while decreasing the overall cost for Earth-to-orbit (ETO) propulsion systems. New ETO propulsion systems will depend on highly reliable fault tolerant flight avionics, advanced sensing systems and artificial intelligence aided software to ensure critical control, safety and maintenance requirements are met in a cost effective manner. Propulsion avionics consist of the engine controller, actuators, sensors, software and ground support elements. In addition to control and safety functions, these elements perform system monitoring for health management. Health management is enhanced by advanced sensing systems and algorithms which provide automated fault detection and enable adaptive control and/or maintenance approaches. Aerojet is developing advanced fault tolerant rocket engine controllers which provide very high levels of reliability. Smart sensors and software systems which significantly enhance fault coverage and enable automated operations are also under development. Smart sensing systems, such as flight capable plume spectrometers, have reached maturity in ground-based applications and are suitable for bridging to flight. Software to detect failed sensors has reached similar maturity. This paper will discuss fault detection and isolation for advanced rocket engine controllers as well as examples of advanced sensing systems and software which significantly improve component failure detection for engine system safety and health management.
Wu, Yuhua; Wang, Yulei; Li, Jun; Li, Wei; Zhang, Li; Li, Yunjing; Li, Xiaofei; Li, Jun; Zhu, Li; Wu, Gang
2014-01-01
The Cauliflower mosaic virus (CaMV) 35S promoter (P35S) is a commonly used target for detection of genetically modified organisms (GMOs). There are currently 24 reported detection methods, targeting different regions of the P35S promoter. Initial assessment revealed that due to the absence of primer binding sites in the P35S sequence, 19 of the 24 reported methods failed to detect P35S in MON88913 cotton, and the other two methods could only be applied to certain GMOs. The rest three reported methods were not suitable for measurement of P35S in some testing events, because SNPs in binding sites of the primer/probe would result in abnormal amplification plots and poor linear regression parameters. In this study, we discovered a conserved region in the P35S sequence through sequencing of P35S promoters from multiple transgenic events, and developed new qualitative and quantitative detection systems targeting this conserved region. The qualitative PCR could detect the P35S promoter in 23 unique GMO events with high specificity and sensitivity. The quantitative method was suitable for measurement of P35S promoter, exhibiting good agreement between the amount of template and Ct values for each testing event. This study provides a general P35S screening method, with greater coverage than existing methods. PMID:25483893
NASA Astrophysics Data System (ADS)
Bermúdez-Montaña, M.; Lemus, R.; Castaños, O.
2017-12-01
In a system of two interacting harmonic oscillators a local-to-normal mode transition is manifested as a polyad breaking phenomenon. This phenomenon is associated with the suitability to estimate zeroth-order force constants in the framework of a local mode description. This transition is also exhibited in two interacting Morse oscillators. To study this case, an appropriate parameterisation going from a molecule with local mode behaviour (H2O) to a molecule presenting a normal mode behaviour (CO2) is introduced. Concepts from quantum mechanics like fidelity, entropy and probability density, as well from nonlinear classical mechanics like Poincaré sections are used to detect the transition region. It is found that fidelity and entropy are sensitive complementary properties to detect the local-to-normal transition. Poincaré sections allow the local-to-normal transition to be detected through the appearance of chaos as a consequence of the polyad breaking phenomenon. In addition, two kinds of avoided energy crossings are identified in accordance with the different regions of the spectrum.
Zhang, Yunqing; Zhang, Xinju; Xu, Xiao; Kang, Zhihua; Li, Shibao; Zhang, Chen; Su, Bing
2014-01-01
A multiplex snapback primer system was developed for the simultaneous detection of JAK2 V617F and MPL W515L/K mutations in Philadelphia chromosome- (Ph-) negative myeloproliferative neoplasms (MPNs). The multiplex system comprises two snapback versus limiting primer sets for JAK2 and MPL mutation enrichment and detection, respectively. Linear-After exponential (LATE) PCR strategy was employed for the primer design to maximize the amplification efficiency of the system. Low ionic strength buffer and rapid PCR protocol allowed for selective amplification of the mutant alleles. Amplification products were analyzed by melting curve analysis for mutation identification. The multiplex system archived 0.1% mutation load sensitivity and <5% coefficient of variation inter-/intra-assay reproducibility. 120 clinical samples were tested by the multiplex snapback primer assay, and verified with amplification refractory system (ARMS), quantitative PCR (qPCR) and Sanger sequencing method. The multiplex system, with a favored versatility, provided the molecular diagnosis of Ph-negative MPNs with a suitable implement and simplified the genetic test process. PMID:24729973
An improvement in rollover detection of articulated vehicles using the grey system theory
NASA Astrophysics Data System (ADS)
Chou, Tao; Chu, Tzyy-Wen
2014-05-01
A Rollover Index combined with the grey system theory, called a Grey Rollover Index (GRI), is proposed to assess the rollover threat for articulated vehicles with a tractor-semitrailer combination. This index can predict future trends of vehicle dynamics based on current vehicle motion; thus, it is suitable for vehicle-rollover detection. Two difficulties are encountered when applying the GRI for rollover detection. The first difficulty is effectively predicting the rollover threat of the vehicles, and the second difficulty is achieving a definite definition of the real rollover timing of a vehicle. The following methods are used to resolve these problems. First, a nonlinear mathematical model is constructed to accurately describe the vehicle dynamics of articulated vehicles. This model is combined with the GRI to predict rollover propensity. Finally, TruckSim™ software is used to determine the real rollover timing and facilitate the accurate supply of information to the rollover detection system through the GRI. This index is used to verify the simulation based on the common manoeuvres that cause rollover accidents to reduce the occurrence of false signals and effectively increase the efficiency of the rollover detection system.
Signal Waveform Detection with Statistical Automaton for Internet and Web Service Streaming
Liu, Yiming; Huang, Nai-Lun; Zeng, Fufu; Lin, Fang-Ying
2014-01-01
In recent years, many approaches have been suggested for Internet and web streaming detection. In this paper, we propose an approach to signal waveform detection for Internet and web streaming, with novel statistical automatons. The system records network connections over a period of time to form a signal waveform and compute suspicious characteristics of the waveform. Network streaming according to these selected waveform features by our newly designed Aho-Corasick (AC) automatons can be classified. We developed two versions, that is, basic AC and advanced AC-histogram waveform automata, and conducted comprehensive experimentation. The results confirm that our approach is feasible and suitable for deployment. PMID:25032231
The technology on noise reduction of the APD detection circuit
NASA Astrophysics Data System (ADS)
Wu, Xue-ying; Zheng, Yong-chao; Cui, Jian-yong
2013-09-01
The laser pulse detection is widely used in the field of laser range finders, laser communications, laser radar, laser Identification Friend or Foe, et al, for the laser pulse detection has the advantage of high accuracy, high sensitivity and strong anti-interference. The avalanche photodiodes (APD) has the advantage of high quantum efficiency, high response speed and huge gain. The APD is particularly suitable for weak signal detection. The technology that APD acts as the photodetector for weak signal reception and amplification is widely used in laser pulse detection. The APD will convert the laser signal to weak electrical signal. The weak signal is amplified, processed and exported by the circuit. In the circuit design, the optimal signal detection is one key point in photoelectric detection system. The issue discusses how to reduce the noise of the photoelectric signal detection circuit and how to improve the signal-to-noise ratio, related analysis and practice included. The essay analyzes the mathematical model of the signal-to-noise ratio for photoelectric conversion and the noise of the APD photoelectric detection system. By analysis the bandwidth of the detection system is determined, and the circuit devices are selected that match the APD. In the circuit design separated devices with low noise are combined with integrated operational amplifier for the purpose of noise reduction. The methods can effectively suppress the noise, and improve the detection sensitivity.
An Approach to V&V of Embedded Adaptive Systems
NASA Technical Reports Server (NTRS)
Liu, Yan; Yerramalla, Sampath; Fuller, Edgar; Cukic, Bojan; Gururajan, Srikaruth
2004-01-01
Rigorous Verification and Validation (V&V) techniques are essential for high assurance systems. Lately, the performance of some of these systems is enhanced by embedded adaptive components in order to cope with environmental changes. Although the ability of adapting is appealing, it actually poses a problem in terms of V&V. Since uncertainties induced by environmental changes have a significant impact on system behavior, the applicability of conventional V&V techniques is limited. In safety-critical applications such as flight control system, the mechanisms of change must be observed, diagnosed, accommodated and well understood prior to deployment. In this paper, we propose a non-conventional V&V approach suitable for online adaptive systems. We apply our approach to an intelligent flight control system that employs a particular type of Neural Networks (NN) as the adaptive learning paradigm. Presented methodology consists of a novelty detection technique and online stability monitoring tools. The novelty detection technique is based on Support Vector Data Description that detects novel (abnormal) data patterns. The Online Stability Monitoring tools based on Lyapunov's Stability Theory detect unstable learning behavior in neural networks. Cases studies based on a high fidelity simulator of NASA's Intelligent Flight Control System demonstrate a successful application of the presented V&V methodology. ,
Yang, Yi; Foster, Mark; Khurgin, Jacob B; Cooper, A Brinton
2012-07-30
A novel coherent optical code-division multiple access (OCDMA) scheme is proposed that uses spectral line pairing to generate signals suitable for heterodyne decoding. Both signal and local reference are transmitted via a single optical fiber and a simple balanced receiver performs sourceless heterodyne detection, canceling speckle noise and multiple-access interference (MAI). To validate the idea, a 16 user fully loaded phase encoded system is simulated. Effects of fiber dispersion on system performance are studied as well. Both second and third order dispersion management is achieved by using a spectral phase encoder to adjust phase shifts of spectral components at the optical network unit (ONU).
Assessing the performance of a motion tracking system based on optical joint transform correlation
NASA Astrophysics Data System (ADS)
Elbouz, M.; Alfalou, A.; Brosseau, C.; Ben Haj Yahia, N.; Alam, M. S.
2015-08-01
We present an optimized system specially designed for the tracking and recognition of moving subjects in a confined environment (such as an elderly remaining at home). In the first step of our study, we use a VanderLugt correlator (VLC) with an adapted pre-processing treatment of the input plane and a postprocessing of the correlation plane via a nonlinear function allowing us to make a robust decision. The second step is based on an optical joint transform correlation (JTC)-based system (NZ-NL-correlation JTC) for achieving improved detection and tracking of moving persons in a confined space. The proposed system has been found to have significantly superior discrimination and robustness capabilities allowing to detect an unknown target in an input scene and to determine the target's trajectory when this target is in motion. This system offers robust tracking performance of a moving target in several scenarios, such as rotational variation of input faces. Test results obtained using various real life video sequences show that the proposed system is particularly suitable for real-time detection and tracking of moving objects.
Ölçer, İbrahim; Öncü, Ahmet
2017-06-05
Distributed vibration sensing based on phase-sensitive optical time domain reflectometry ( ϕ -OTDR) is being widely used in several applications. However, one of the main challenges in coherent detection-based ϕ -OTDR systems is the fading noise, which impacts the detection performance. In addition, typical signal averaging and differentiating techniques are not suitable for detecting high frequency events. This paper presents a new approach for reducing the effect of fading noise in fiber optic distributed acoustic vibration sensing systems without any impact on the frequency response of the detection system. The method is based on temporal adaptive processing of ϕ -OTDR signals. The fundamental theory underlying the algorithm, which is based on signal-to-noise ratio (SNR) maximization, is presented, and the efficacy of our algorithm is demonstrated with laboratory experiments and field tests. With the proposed digital processing technique, the results show that more than 10 dB of SNR values can be achieved without any reduction in the system bandwidth and without using additional optical amplifier stages in the hardware. We believe that our proposed adaptive processing approach can be effectively used to develop fiber optic-based distributed acoustic vibration sensing systems.
Ölçer, İbrahim; Öncü, Ahmet
2017-01-01
Distributed vibration sensing based on phase-sensitive optical time domain reflectometry (ϕ-OTDR) is being widely used in several applications. However, one of the main challenges in coherent detection-based ϕ-OTDR systems is the fading noise, which impacts the detection performance. In addition, typical signal averaging and differentiating techniques are not suitable for detecting high frequency events. This paper presents a new approach for reducing the effect of fading noise in fiber optic distributed acoustic vibration sensing systems without any impact on the frequency response of the detection system. The method is based on temporal adaptive processing of ϕ-OTDR signals. The fundamental theory underlying the algorithm, which is based on signal-to-noise ratio (SNR) maximization, is presented, and the efficacy of our algorithm is demonstrated with laboratory experiments and field tests. With the proposed digital processing technique, the results show that more than 10 dB of SNR values can be achieved without any reduction in the system bandwidth and without using additional optical amplifier stages in the hardware. We believe that our proposed adaptive processing approach can be effectively used to develop fiber optic-based distributed acoustic vibration sensing systems. PMID:28587240
Design of an FMCW radar baseband signal processing system for automotive application.
Lin, Jau-Jr; Li, Yuan-Ping; Hsu, Wei-Chiang; Lee, Ta-Sung
2016-01-01
For a typical FMCW automotive radar system, a new design of baseband signal processing architecture and algorithms is proposed to overcome the ghost targets and overlapping problems in the multi-target detection scenario. To satisfy the short measurement time constraint without increasing the RF front-end loading, a three-segment waveform with different slopes is utilized. By introducing a new pairing mechanism and a spatial filter design algorithm, the proposed detection architecture not only provides high accuracy and reliability, but also requires low pairing time and computational loading. This proposed baseband signal processing architecture and algorithms balance the performance and complexity, and are suitable to be implemented in a real automotive radar system. Field measurement results demonstrate that the proposed automotive radar signal processing system can perform well in a realistic application scenario.
Jiang, Lingxi; Yang, Litao; Zhang, Haibo; Guo, Jinchao; Mazzara, Marco; Van den Eede, Guy; Zhang, Dabing
2009-05-13
One rice ( Oryza sativa ) gene, sucrose phosphate synthase (SPS), has been proven to be a suitable endogenous reference gene for genetically modified (GM) rice detection in a previous study. Herein are the reported results of an international collaborative ring trial for validation of the SPS gene as an endogenous reference gene and its optimized qualitative and quantitative polymerase chain reaction (PCR) systems. A total of 12 genetically modified organism (GMO) detection laboratories from seven countries participated in the ring trial and returned their results. The validated results confirmed the species specificity of the method through testing 10 plant genomic DNAs, low heterogeneity, and a stable single-copy number of the rice SPS gene among 7 indica varieties and 5 japonica varieties. The SPS qualitative PCR assay was validated with a limit of detection (LOD) of 0.1%, which corresponded to about 230 copies of haploid rice genomic DNA, while the limit of quantification (LOQ) for the quantitative PCR system was about 23 copies of haploid rice genomic DNA, with acceptable PCR efficiency and linearity. Furthermore, the bias between the test and true values of eight blind samples ranged from 5.22 to 26.53%. Thus, we believe that the SPS gene is suitable for use as an endogenous reference gene for the identification and quantification of GM rice and its derivates.
Pixel color feature enhancement for road signs detection
NASA Astrophysics Data System (ADS)
Zhang, Qieshi; Kamata, Sei-ichiro
2010-02-01
Road signs play an important role in our daily life which used to guide drivers to notice variety of road conditions and cautions. They provide important visual information that can help drivers operating their vehicles in a manner for enhancing traffic safety. The occurrence of some accidents can be reduced by using automatic road signs recognition system which can alert the drivers. This research attempts to develop a warning system to alert the drivers to notice the important road signs early enough to refrain road accidents from happening. For solving this, a non-linear weighted color enhancement method by pixels is presented. Due to the advantage of proposed method, different road signs can be detected from videos effectively. With suitably coefficients and operations, the experimental results have proved that the proposed method is robust, accurate and powerful in road signs detection.
Nonadiabatic tapered optical fiber sensor for measuring interaction nicotine with DNA
NASA Astrophysics Data System (ADS)
Zibaii, M. I.; Latifi, H.; Pourbeyram, H.; Gholami, M.; Taghipour, Z.; Saeedian, Z.; Hosseini, S. M.
2011-05-01
A nonadiabatic tapered optical fiber sensor was utilized for studying of bimolecular interactions including DNA-DNA and DNA-Drug interaction. This work presents a simple evanescent wave sensing system based on an interferometric approach, suitable to meet the requirements of lable-free sensor systems for detecting biomolecular interactions. We have demonstrated the measuring refractive index and the real time detection of interactions between biomolecules. Furthermore basic experiments were carried out, for detecting the hybridization of 25-mer DNA with an immobilized counterpart on the surface. The overall shift after the successful DNA hybridization was 9.5 nm. In this work, a new approach for studying DNA-drug interactions was successfully tested. Nicotine as a carcinogenic compound in cigarette smoke plays an important role in interaction with DNA. Different concentrations of nicotine were applied to observe the Longmuir interaction with DNA.
A sensitive, handheld vapor sensor based on microcantilevers
NASA Astrophysics Data System (ADS)
Pinnaduwage, L. A.; Hedden, D. L.; Gehl, A.; Boiadjiev, V. I.; Hawk, J. E.; Farahi, R. H.; Thundat, T.; Houser, E. J.; Stepnowski, S.; McGill, R. A.; Deel, L.; Lareau, R. T.
2004-11-01
We report the development of a handheld sensor based on piezoresistive microcantilevers that does not depend on optical detection, yet has high detection sensitivity. The sensor is able to detect vapors from the plastic explosives pentaerythritol tetranitrate and hexahydro-1,3,5-triazine at levels below 10 parts per trillion within few seconds of exposure under ambient conditions. A differential measurement technique has yielded a rugged sensor that is unaffected by vibration and is able to function as a "sniffer." The microelectromechanical system sensor design allows for the incorporation of hundreds of microcantilevers with suitable coatings in order to achieve sufficient selectivity in the future, and thus could provide an inexpensive, unique platform for the detection of chemical, biological, and explosive materials.
Single-Frequency Ultrasound-Based Respiration Rate Estimation with Smartphones.
Ge, Linfei; Zhang, Jin; Wei, Jing
2018-01-01
Respiration monitoring is helpful in disease prevention and diagnosis. Traditional respiration monitoring requires users to wear devices on their bodies, which is inconvenient for them. In this paper, we aim to design a noncontact respiration rate detection system utilizing off-the-shelf smartphones. We utilize the single-frequency ultrasound as the media to detect the respiration activity. By analyzing the ultrasound signals received by the built-in microphone sensor in a smartphone, our system can derive the respiration rate of the user. The advantage of our method is that the transmitted signal is easy to generate and the signal analysis is simple, which has lower power consumption and thus is suitable for long-term monitoring in daily life. The experimental result shows that our system can achieve accurate respiration rate estimation under various scenarios.
A semantic autonomous video surveillance system for dense camera networks in Smart Cities.
Calavia, Lorena; Baladrón, Carlos; Aguiar, Javier M; Carro, Belén; Sánchez-Esguevillas, Antonio
2012-01-01
This paper presents a proposal of an intelligent video surveillance system able to detect and identify abnormal and alarming situations by analyzing object movement. The system is designed to minimize video processing and transmission, thus allowing a large number of cameras to be deployed on the system, and therefore making it suitable for its usage as an integrated safety and security solution in Smart Cities. Alarm detection is performed on the basis of parameters of the moving objects and their trajectories, and is performed using semantic reasoning and ontologies. This means that the system employs a high-level conceptual language easy to understand for human operators, capable of raising enriched alarms with descriptions of what is happening on the image, and to automate reactions to them such as alerting the appropriate emergency services using the Smart City safety network.
A Semantic Autonomous Video Surveillance System for Dense Camera Networks in Smart Cities
Calavia, Lorena; Baladrón, Carlos; Aguiar, Javier M.; Carro, Belén; Sánchez-Esguevillas, Antonio
2012-01-01
This paper presents a proposal of an intelligent video surveillance system able to detect and identify abnormal and alarming situations by analyzing object movement. The system is designed to minimize video processing and transmission, thus allowing a large number of cameras to be deployed on the system, and therefore making it suitable for its usage as an integrated safety and security solution in Smart Cities. Alarm detection is performed on the basis of parameters of the moving objects and their trajectories, and is performed using semantic reasoning and ontologies. This means that the system employs a high-level conceptual language easy to understand for human operators, capable of raising enriched alarms with descriptions of what is happening on the image, and to automate reactions to them such as alerting the appropriate emergency services using the Smart City safety network. PMID:23112607
Capability of long distance 100 GHz FMCW using a single GDD lamp sensor.
Levanon, Assaf; Rozban, Daniel; Aharon Akram, Avihai; Kopeika, Natan S; Yitzhaky, Yitzhak; Abramovich, Amir
2014-12-20
Millimeter wave (MMW)-based imaging systems are required for applications in medicine, homeland security, concealed weapon detection, and space technology. The lack of inexpensive room temperature imaging sensors makes it difficult to provide a suitable MMW system for many of the above applications. A 3D MMW imaging system based on chirp radar was studied previously using a scanning imaging system of a single detector. The radar system requires that the millimeter wave detector will be able to operate as a heterodyne detector. Since the source of radiation is a frequency modulated continuous wave (FMCW), the detected signal as a result of heterodyne detection gives the object's depth information according to value of difference frequency, in addition to the reflectance of the 2D image. New experiments show the capability of long distance FMCW detection by using a large scale Cassegrain projection system, described first (to our knowledge) in this paper. The system presents the capability to employ a long distance of at least 20 m with a low-cost plasma-based glow discharge detector (GDD) focal plane array (FPA). Each point on the object corresponds to a point in the image and includes the distance information. This will enable relatively inexpensive 3D MMW imaging.
Gustavsson, Inger; Lindell, Monica; Wilander, Erik; Strand, Anders; Gyllensten, Ulf
2009-10-01
The FTA elute micro card, which enable the collection, transport, and archiving of DNA could be an attractive alternative to a liquid based collection system for detection of human papillomavirus (HPV). To develop a method based on the FTA elute micro card for dry collection of cervical epithelial cell samples, suitable for subsequent PCR-based HPV testing. The method was evaluated by a comparison of the DNA collected by cytobrush and the regular FTA elute micro card from 50 cervical cell samples. The method was then used to estimate the DNA amount in 1040 samples applied to the indicating FTA elute micro card. The agreement in HPV positivity between the cytobrush and FTA samples (94%) was excellent (kappa=0.88, 95% CI 0.748-1). All the 1040 samples on the indicating FTA card had sufficient amounts of genomic DNA (>10 copies of a single copy gene) to be suitable for HPV typing. In 53 of the 1040 women the day in the menstrual cycle was noted, and the copy number during follicular phase day 9-13 was found to be statistically significantly lower than for the other three stages in the menstrual cycle (day 4-8, 14, >14) and during menopause. The indicating FTA elute micro card represents a suitable medium for collection of cervical cell samples, although follow-up studies are needed to verify the detection of low frequency HPV types.
Ruettger, Anke; Nieter, Johanna; Skrypnyk, Artem; Engelmann, Ines; Ziegler, Albrecht; Moser, Irmgard; Monecke, Stefan; Ehricht, Ralf
2012-01-01
Membrane-based spoligotyping has been converted to DNA microarray format to qualify it for high-throughput testing. We have shown the assay's validity and suitability for direct typing from tissue and detecting new spoligotypes. Advantages of the microarray methodology include rapidity, ease of operation, automatic data processing, and affordability. PMID:22553239
Ruettger, Anke; Nieter, Johanna; Skrypnyk, Artem; Engelmann, Ines; Ziegler, Albrecht; Moser, Irmgard; Monecke, Stefan; Ehricht, Ralf; Sachse, Konrad
2012-07-01
Membrane-based spoligotyping has been converted to DNA microarray format to qualify it for high-throughput testing. We have shown the assay's validity and suitability for direct typing from tissue and detecting new spoligotypes. Advantages of the microarray methodology include rapidity, ease of operation, automatic data processing, and affordability.
A Cost-effective and Reliable Method to Predict Mechanical Stress in Single-use and Standard Pumps
Dittler, Ina; Dornfeld, Wolfgang; Schöb, Reto; Cocke, Jared; Rojahn, Jürgen; Kraume, Matthias; Eibl, Dieter
2015-01-01
Pumps are mainly used when transferring sterile culture broths in biopharmaceutical and biotechnological production processes. However, during the pumping process shear forces occur which can lead to qualitative and/or quantitative product loss. To calculate the mechanical stress with limited experimental expense, an oil-water emulsion system was used, whose suitability was demonstrated for drop size detections in bioreactors1. As drop breakup of the oil-water emulsion system is a function of mechanical stress, drop sizes need to be counted over the experimental time of shear stress investigations. In previous studies, the inline endoscopy has been shown to be an accurate and reliable measurement technique for drop size detections in liquid/liquid dispersions. The aim of this protocol is to show the suitability of the inline endoscopy technique for drop size measurements in pumping processes. In order to express the drop size, the Sauter mean diameter d32 was used as the representative diameter of drops in the oil-water emulsion. The results showed low variation in the Sauter mean diameters, which were quantified by standard deviations of below 15%, indicating the reliability of the measurement technique. PMID:26274765
Evolutionary neural networks for anomaly detection based on the behavior of a program.
Han, Sang-Jun; Cho, Sung-Bae
2006-06-01
The process of learning the behavior of a given program by using machine-learning techniques (based on system-call audit data) is effective to detect intrusions. Rule learning, neural networks, statistics, and hidden Markov models (HMMs) are some of the kinds of representative methods for intrusion detection. Among them, neural networks are known for good performance in learning system-call sequences. In order to apply this knowledge to real-world problems successfully, it is important to determine the structures and weights of these call sequences. However, finding the appropriate structures requires very long time periods because there are no suitable analytical solutions. In this paper, a novel intrusion-detection technique based on evolutionary neural networks (ENNs) is proposed. One advantage of using ENNs is that it takes less time to obtain superior neural networks than when using conventional approaches. This is because they discover the structures and weights of the neural networks simultaneously. Experimental results with the 1999 Defense Advanced Research Projects Agency (DARPA) Intrusion Detection Evaluation (IDEVAL) data confirm that ENNs are promising tools for intrusion detection.
Optimal Attack Strategies Subject to Detection Constraints Against Cyber-Physical Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, Yuan; Kar, Soummya; Moura, Jose M. F.
This paper studies an attacker against a cyberphysical system (CPS) whose goal is to move the state of a CPS to a target state while ensuring that his or her probability of being detected does not exceed a given bound. The attacker’s probability of being detected is related to the nonnegative bias induced by his or her attack on the CPS’s detection statistic. We formulate a linear quadratic cost function that captures the attacker’s control goal and establish constraints on the induced bias that reflect the attacker’s detection-avoidance objectives. When the attacker is constrained to be detected at the false-alarmmore » rate of the detector, we show that the optimal attack strategy reduces to a linear feedback of the attacker’s state estimate. In the case that the attacker’s bias is upper bounded by a positive constant, we provide two algorithms – an optimal algorithm and a sub-optimal, less computationally intensive algorithm – to find suitable attack sequences. Lastly, we illustrate our attack strategies in numerical examples based on a remotely-controlled helicopter under attack.« less
Optimal Attack Strategies Subject to Detection Constraints Against Cyber-Physical Systems
Chen, Yuan; Kar, Soummya; Moura, Jose M. F.
2017-03-31
This paper studies an attacker against a cyberphysical system (CPS) whose goal is to move the state of a CPS to a target state while ensuring that his or her probability of being detected does not exceed a given bound. The attacker’s probability of being detected is related to the nonnegative bias induced by his or her attack on the CPS’s detection statistic. We formulate a linear quadratic cost function that captures the attacker’s control goal and establish constraints on the induced bias that reflect the attacker’s detection-avoidance objectives. When the attacker is constrained to be detected at the false-alarmmore » rate of the detector, we show that the optimal attack strategy reduces to a linear feedback of the attacker’s state estimate. In the case that the attacker’s bias is upper bounded by a positive constant, we provide two algorithms – an optimal algorithm and a sub-optimal, less computationally intensive algorithm – to find suitable attack sequences. Lastly, we illustrate our attack strategies in numerical examples based on a remotely-controlled helicopter under attack.« less
[The subcutaneous cardioverter-defibrillator: When less is more].
Kuschyk, J; Rudic, B; Akin, I; Borggrefe, M; Röger, S
2015-06-01
In the last few decades, defibrillator therapy has revolutionized treatment of patients at risk for sudden cardiac death. Multiple clinical trials have shown the benefit of implantable cardioverter-defibrillators (ICD) for primary and secondary prevention of sudden cardiac death. Being an entirely subcutaneous system, the S-ICD® avoids important periprocedural and long-term complications associated with transvenous implantable cardioverter-defibrillator (TV-ICD) systems as well as the need for fluoroscopy during implant surgery. In patients with challenging anatomic conditions or after infection, the S-ICD® might be reasonable. In multicenter studies and registries efficacy and safety of the S-ICD® was equal or better to transvenous implantable defibrillators. The cardiac rhythm is detected by the use of 1 of the 3 potential vectors. The S-ICD® automatically selects the most suitable vector for rhythm detection. If ventricular tachyarrhythmia is detected, the device is able to deliver up to five shocks of 80 J, while postshock pacing is available at 50 bpm for 30 s. The implantation technique is different from that of conventional ICDs, but easily learnable by experienced cardiologists. Initially observed hurdles (e.g., inappropriate shocks or infections) have been overcome by standardized implantation techniques, operator learning curves, and modification of algorithms. The S-ICD® predominately might be suitable in all patients with ICD indication except patients with pacing or cardiac resynchronization therapy (CRT) indication, ventricular tachycardia < 170 bpm, negative screening, or in the occasional patient whose arrhythmia might be suppressed by overdrive pacing. The system received CE certification in 2009 and was approved by the FDA in 2012. Currently, in Germany the S-ICD® has been integrated into the DRG system and can be reimbursed as a single chamber ICD.
A novel multisensor traffic state assessment system based on incomplete data.
Zeng, Yiliang; Lan, Jinhui; Ran, Bin; Jiang, Yaoliang
2014-01-01
A novel multisensor system with incomplete data is presented for traffic state assessment. The system comprises probe vehicle detection sensors, fixed detection sensors, and traffic state assessment algorithm. First of all, the validity checking of the traffic flow data is taken as preprocessing of this method. And then a new method based on the history data information is proposed to fuse and recover the incomplete data. According to the characteristics of space complementary of data based on the probe vehicle detector and fixed detector, a fusion model of space matching is presented to estimate the mean travel speed of the road. Finally, the traffic flow data include flow, speed and, occupancy rate, which are detected between Beijing Deshengmen bridge and Drum Tower bridge, are fused to assess the traffic state of the road by using the fusion decision model of rough sets and cloud. The accuracy of experiment result can reach more than 98%, and the result is in accordance with the actual road traffic state. This system is effective to assess traffic state, and it is suitable for the urban intelligent transportation system.
Pre-processing of data coming from a laser-EMAT system for non-destructive testing of steel slabs.
Sgarbi, Mirko; Colla, Valentina; Cateni, Sivia; Higson, Stuart
2012-01-01
Non destructive test systems are increasingly applied in the industrial context for their strong potentialities in improving and standardizing quality control. Especially in the intermediate manufacturing stages, early detection of defects on semi-finished products allow their direction towards later production processes according to their quality, with consequent considerable savings in time, energy, materials and work. However, the raw data coming from non destructive test systems are not always immediately suitable for sophisticated defect detection algorithms, due to noise and disturbances which are unavoidable, especially in harsh operating conditions, such as the ones which are typical of the steelmaking cycle. The paper describes some pre-processing operations which are required in order to exploit the data coming from a non destructive test system. Such a system is based on the joint exploitation of Laser and Electro-Magnetic Acoustic Transducer technologies and is applied to the detection of surface and sub-surface cracks in cold and hot steel slabs. Copyright © 2011 ISA. Published by Elsevier Ltd. All rights reserved.
A Novel Multisensor Traffic State Assessment System Based on Incomplete Data
Zeng, Yiliang; Lan, Jinhui; Ran, Bin; Jiang, Yaoliang
2014-01-01
A novel multisensor system with incomplete data is presented for traffic state assessment. The system comprises probe vehicle detection sensors, fixed detection sensors, and traffic state assessment algorithm. First of all, the validity checking of the traffic flow data is taken as preprocessing of this method. And then a new method based on the history data information is proposed to fuse and recover the incomplete data. According to the characteristics of space complementary of data based on the probe vehicle detector and fixed detector, a fusion model of space matching is presented to estimate the mean travel speed of the road. Finally, the traffic flow data include flow, speed and, occupancy rate, which are detected between Beijing Deshengmen bridge and Drum Tower bridge, are fused to assess the traffic state of the road by using the fusion decision model of rough sets and cloud. The accuracy of experiment result can reach more than 98%, and the result is in accordance with the actual road traffic state. This system is effective to assess traffic state, and it is suitable for the urban intelligent transportation system. PMID:25162055
Simultaneous Sensor and Process Fault Diagnostics for Propellant Feed System
NASA Technical Reports Server (NTRS)
Cao, J.; Kwan, C.; Figueroa, F.; Xu, R.
2006-01-01
The main objective of this research is to extract fault features from sensor faults and process faults by using advanced fault detection and isolation (FDI) algorithms. A tank system that has some common characteristics to a NASA testbed at Stennis Space Center was used to verify our proposed algorithms. First, a generic tank system was modeled. Second, a mathematical model suitable for FDI has been derived for the tank system. Third, a new and general FDI procedure has been designed to distinguish process faults and sensor faults. Extensive simulations clearly demonstrated the advantages of the new design.
Grayscale image segmentation for real-time traffic sign recognition: the hardware point of view
NASA Astrophysics Data System (ADS)
Cao, Tam P.; Deng, Guang; Elton, Darrell
2009-02-01
In this paper, we study several grayscale-based image segmentation methods for real-time road sign recognition applications on an FPGA hardware platform. The performance of different image segmentation algorithms in different lighting conditions are initially compared using PC simulation. Based on these results and analysis, suitable algorithms are implemented and tested on a real-time FPGA speed sign detection system. Experimental results show that the system using segmented images uses significantly less hardware resources on an FPGA while maintaining comparable system's performance. The system is capable of processing 60 live video frames per second.
Dubber, Donata; Gill, Laurence W
2017-12-15
Rural river catchments are impacted by diffuse pollution sources from agricultural practices and on-site domestic wastewater treatment systems (DWWTS), mainly septic tanks. Methods that can distinguish between contamination sources will significantly increase water management efficiency as they will allow for the development and application of targeted remediation measures. Fluorescent whitening compounds (FWC), are used as optical brighteners in laundry detergents and enter the environment through the discharge of domestic wastewater effluents. Due to their human specific source and potential simple fluorometric measurement this represents a very attractive method to be used by state monitoring agencies. In this study the suitability of FWCs as chemical indicators for human faecal contamination has been investigated in rural Irish catchments. It was found that no quantitative measurements are possible for FWCs in natural waters when using simple fluorometric methods. Hence a simple presence/absence approach needs to be applied. The detectability of FWCs was quantified and found to decrease with higher organic matter content of the river water which has its own fluorescence. This enabled the establishment of equations to predict detection limits and assess the method's suitability for individual catchments based on organic matter concentrations. Furthermore a modified photodecay method is suggested that increases sensitivity of the technique by up to 59%. Applications at rural study sites found some removal of FWCs in percolation areas of DWWTSs but they were still detectable 40 cm below the infiltration depth. FWCs were also detected as distinguishable peaks in impacted streams where septic tank effluents have a high contribution to the river flow. Copyright © 2017 Elsevier Ltd. All rights reserved.
Remote laser drilling and sampling system for the detection of concealed explosives
NASA Astrophysics Data System (ADS)
Wild, D.; Pschyklenk, L.; Theiß, C.; Holl, G.
2017-05-01
The detection of hazardous materials like explosives is a central issue in national security in the field of counterterrorism. One major task includes the development of new methods and sensor systems for the detection. Many existing remote or standoff methods like infrared or raman spectroscopy find their limits, if the hazardous material is concealed in an object. Imaging technologies using x-ray or terahertz radiation usually yield no information about the chemical content itself. However, the exact knowledge of the real threat potential of a suspicious object is crucial for disarming the device. A new approach deals with a laser drilling and sampling system for the use as verification detector for suspicious objects. Central part of the system is a miniaturised, diode pumped Nd:YAG laser oscillator-amplifier. The system allows drilling into most materials like metals, synthetics or textiles with bore hole diameters in the micron scale. During the drilling process, the hazardous material can be sampled for further investigation with suitable detection methods. In the reported work, laser induced breakdown spectroscopy (LIBS) is used to monitor the drilling process and to classify the drilled material. Also experiments were carried out to show the system's ability to not ignite even sensitive explosives like triacetone triperoxide (TATP). The detection of concealed hazardous material is shown for different explosives using liquid chromatography and ion mobility spectrometry.
NASA Astrophysics Data System (ADS)
Martinenghi, E.; Di Sieno, L.; Contini, D.; Sanzaro, M.; Pifferi, A.; Dalla Mora, A.
2016-07-01
We present the design and preliminary characterization of the first detection module based on Silicon Photomultiplier (SiPM) tailored for single-photon timing applications. The aim of this work is to demonstrate, thanks to the design of a suitable module, the possibility to easily exploit SiPM in many applications as an interesting detector featuring large active area, similarly to photomultipliers tubes, but keeping the advantages of solid state detectors (high quantum efficiency, low cost, compactness, robustness, low bias voltage, and insensitiveness to magnetic field). The module integrates a cooled SiPM with a total photosensitive area of 1 mm2 together with the suitable avalanche signal read-out circuit, the signal conditioning, the biasing electronics, and a Peltier cooler driver for thermal stabilization. It is able to extract the single-photon timing information with resolution better than 100 ps full-width at half maximum. We verified the effective stabilization in response to external thermal perturbations, thus proving the complete insensitivity of the module to environment temperature variations, which represents a fundamental parameter to profitably use the instrument for real-field applications. We also characterized the single-photon timing resolution, the background noise due to both primary dark count generation and afterpulsing, the single-photon detection efficiency, and the instrument response function shape. The proposed module can become a reliable and cost-effective building block for time-correlated single-photon counting instruments in applications requiring high collection capability of isotropic light and detection efficiency (e.g., fluorescence decay measurements or time-domain diffuse optics systems).
Osborne, D J; Peters, B J; Meade, C J
1983-11-01
The following high performance liquid chromatography system was found suitable for separating most lipoxygenase metabolites of arachidonic acid: Techsphere 5-C18 column, eluting solvent methanol:water:acetic acid (65:35:0.06 v/v), pH 5.3. Comparisons with other packing materials and solvent systems are described. The method could be used to identify lipoxygenase products released from mouse macrophage cells stimulated with gamma-hexachlorocyclohexane. Detection limits between 1 and 10 ng were obtained.
NASA Technical Reports Server (NTRS)
Rushby, John; Crow, Judith
1990-01-01
The authors explore issues in the specification, verification, and validation of artificial intelligence (AI) based software, using a prototype fault detection, isolation and recovery (FDIR) system for the Manned Maneuvering Unit (MMU). They use this system as a vehicle for exploring issues in the semantics of C-Language Integrated Production System (CLIPS)-style rule-based languages, the verification of properties relating to safety and reliability, and the static and dynamic analysis of knowledge based systems. This analysis reveals errors and shortcomings in the MMU FDIR system and raises a number of issues concerning software engineering in CLIPs. The authors came to realize that the MMU FDIR system does not conform to conventional definitions of AI software, despite the fact that it was intended and indeed presented as an AI system. The authors discuss this apparent disparity and related questions such as the role of AI techniques in space and aircraft operations and the suitability of CLIPS for critical applications.
NASA Astrophysics Data System (ADS)
Hosotani, Daisuke; Yoda, Ikushi; Hishiyama, Yoshiyuki; Sakaue, Katsuhiko
Many people are involved in accidents every year at railroad crossings, but there is no suitable sensor for detecting pedestrians. We are therefore developing a ubiquitous stereo vision based system for ensuring safety at railroad crossings. In this system, stereo cameras are installed at the corners and are pointed toward the center of the railroad crossing to monitor the passage of people. The system determines automatically and in real-time whether anyone or anything is inside the railroad crossing, and whether anyone remains in the crossing. The system can be configured to automatically switch over to a surveillance monitor or automatically connect to an emergency brake system in the event of trouble. We have developed an original stereovision device and installed the remote controlled experimental system applied human detection algorithm in the commercial railroad crossing. Then we store and analyze image data and tracking data throughout two years for standardization of system requirement specification.
Novel Noninvasive Brain Disease Detection System Using a Facial Image Sensor
Shu, Ting; Zhang, Bob; Tang, Yuan Yan
2017-01-01
Brain disease including any conditions or disabilities that affect the brain is fast becoming a leading cause of death. The traditional diagnostic methods of brain disease are time-consuming, inconvenient and non-patient friendly. As more and more individuals undergo examinations to determine if they suffer from any form of brain disease, developing noninvasive, efficient, and patient friendly detection systems will be beneficial. Therefore, in this paper, we propose a novel noninvasive brain disease detection system based on the analysis of facial colors. The system consists of four components. A facial image is first captured through a specialized sensor, where four facial key blocks are next located automatically from the various facial regions. Color features are extracted from each block to form a feature vector for classification via the Probabilistic Collaborative based Classifier. To thoroughly test the system and its performance, seven facial key block combinations were experimented. The best result was achieved using the second facial key block, where it showed that the Probabilistic Collaborative based Classifier is the most suitable. The overall performance of the proposed system achieves an accuracy −95%, a sensitivity −94.33%, a specificity −95.67%, and an average processing time (for one sample) of <1 min at brain disease detection. PMID:29292716
Elgendi, Mohamed; Eskofier, Björn; Dokos, Socrates; Abbott, Derek
2014-01-01
Cardiovascular diseases are the number one cause of death worldwide. Currently, portable battery-operated systems such as mobile phones with wireless ECG sensors have the potential to be used in continuous cardiac function assessment that can be easily integrated into daily life. These portable point-of-care diagnostic systems can therefore help unveil and treat cardiovascular diseases. The basis for ECG analysis is a robust detection of the prominent QRS complex, as well as other ECG signal characteristics. However, it is not clear from the literature which ECG analysis algorithms are suited for an implementation on a mobile device. We investigate current QRS detection algorithms based on three assessment criteria: 1) robustness to noise, 2) parameter choice, and 3) numerical efficiency, in order to target a universal fast-robust detector. Furthermore, existing QRS detection algorithms may provide an acceptable solution only on small segments of ECG signals, within a certain amplitude range, or amid particular types of arrhythmia and/or noise. These issues are discussed in the context of a comparison with the most conventional algorithms, followed by future recommendations for developing reliable QRS detection schemes suitable for implementation on battery-operated mobile devices.
Elgendi, Mohamed; Eskofier, Björn; Dokos, Socrates; Abbott, Derek
2014-01-01
Cardiovascular diseases are the number one cause of death worldwide. Currently, portable battery-operated systems such as mobile phones with wireless ECG sensors have the potential to be used in continuous cardiac function assessment that can be easily integrated into daily life. These portable point-of-care diagnostic systems can therefore help unveil and treat cardiovascular diseases. The basis for ECG analysis is a robust detection of the prominent QRS complex, as well as other ECG signal characteristics. However, it is not clear from the literature which ECG analysis algorithms are suited for an implementation on a mobile device. We investigate current QRS detection algorithms based on three assessment criteria: 1) robustness to noise, 2) parameter choice, and 3) numerical efficiency, in order to target a universal fast-robust detector. Furthermore, existing QRS detection algorithms may provide an acceptable solution only on small segments of ECG signals, within a certain amplitude range, or amid particular types of arrhythmia and/or noise. These issues are discussed in the context of a comparison with the most conventional algorithms, followed by future recommendations for developing reliable QRS detection schemes suitable for implementation on battery-operated mobile devices. PMID:24409290
Rajadhyaksha, Milind
2012-01-01
Abstract. Coherent speckle influences the resulting image when narrow spectral line-width and single spatial mode illumination are used, though these are the same light-source properties that provide the best radiance-to-cost ratio. However, a suitable size of the detection pinhole can be chosen to maintain adequate optical sectioning while making the probability density of the speckle noise more normal and reducing its effect. The result is a qualitatively better image with improved contrast, which is easier to read. With theoretical statistics and experimental results, we show that the detection pinhole size is a fundamental parameter for designing imaging systems for use in turbid media. PMID:23224184
Evaluation of indirect impedance for measuring microbial growth in complex food matrices.
Johnson, N; Chang, Z; Bravo Almeida, C; Michel, M; Iversen, C; Callanan, M
2014-09-01
The suitability of indirect impedance to accurately measure microbial growth in real food matrices was investigated. A variety of semi-solid and liquid food products were inoculated with Bacillus cereus, Listeria monocytogenes, Staphylococcus aureus, Lactobacillus plantarum, Pseudomonas aeruginosa, Escherichia coli, Salmonella enteriditis, Candida tropicalis or Zygosaccharomyces rouxii and CO2 production was monitored using a conductimetric (Don Whitely R.A.B.I.T.) system. The majority (80%) of food and microbe combinations produced a detectable growth signal. The linearity of conductance responses in selected food products was investigated and a good correlation (R(2) ≥ 0.84) was observed between inoculum levels and times to detection. Specific growth rate estimations from the data were sufficiently accurate for predictive modeling in some cases. This initial evaluation of the suitability of indirect impedance to generate microbial growth data in complex food matrices indicates significant potential for the technology as an alternative to plating methods. Copyright © 2014 Elsevier Ltd. All rights reserved.
Automated synthesis, insertion and detection of polyps for CT colonography
NASA Astrophysics Data System (ADS)
Sezille, Nicolas; Sadleir, Robert J. T.; Whelan, Paul F.
2003-03-01
CT Colonography (CTC) is a new non-invasive colon imaging technique which has the potential to replace conventional colonoscopy for colorectal cancer screening. A novel system which facilitates automated detection of colorectal polyps at CTC is introduced. As exhaustive testing of such a system using real patient data is not feasible, more complete testing is achieved through synthesis of artificial polyps and insertion into real datasets. The polyp insertion is semi-automatic: candidate points are manually selected using a custom GUI, suitable points are determined automatically from an analysis of the local neighborhood surrounding each of the candidate points. Local density and orientation information are used to generate polyps based on an elliptical model. Anomalies are identified from the modified dataset by analyzing the axial images. Detected anomalies are classified as potential polyps or natural features using 3D morphological techniques. The final results are flagged for review. The system was evaluated using 15 scenarios. The sensitivity of the system was found to be 65% with 34% false positive detections. Automated diagnosis at CTC is possible and thorough testing is facilitated by augmenting real patient data with computer generated polyps. Ultimately, automated diagnosis will enhance standard CTC and increase performance.
Thermal tracking in mobile robots for leak inspection activities.
Ibarguren, Aitor; Molina, Jorge; Susperregi, Loreto; Maurtua, Iñaki
2013-10-09
Maintenance tasks are crucial for all kind of industries, especially in extensive industrial plants, like solar thermal power plants. The incorporation of robots is a key issue for automating inspection activities, as it will allow a constant and regular control over the whole plant. This paper presents an autonomous robotic system to perform pipeline inspection for early detection and prevention of leakages in thermal power plants, based on the work developed within the MAINBOT (http://www.mainbot.eu) European project. Based on the information provided by a thermographic camera, the system is able to detect leakages in the collectors and pipelines. Beside the leakage detection algorithms, the system includes a particle filter-based tracking algorithm to keep the target in the field of view of the camera and to avoid the irregularities of the terrain while the robot patrols the plant. The information provided by the particle filter is further used to command a robot arm, which handles the camera and ensures that the target is always within the image. The obtained results show the suitability of the proposed approach, adding a tracking algorithm to improve the performance of the leakage detection system.
Thermal Tracking in Mobile Robots for Leak Inspection Activities
Ibarguren, Aitor; Molina, Jorge; Susperregi, Loreto; Maurtua, Iñaki
2013-01-01
Maintenance tasks are crucial for all kind of industries, especially in extensive industrial plants, like solar thermal power plants. The incorporation of robots is a key issue for automating inspection activities, as it will allow a constant and regular control over the whole plant. This paper presents an autonomous robotic system to perform pipeline inspection for early detection and prevention of leakages in thermal power plants, based on the work developed within the MAINBOT (http://www.mainbot.eu) European project. Based on the information provided by a thermographic camera, the system is able to detect leakages in the collectors and pipelines. Beside the leakage detection algorithms, the system includes a particle filter-based tracking algorithm to keep the target in the field of view of the camera and to avoid the irregularities of the terrain while the robot patrols the plant. The information provided by the particle filter is further used to command a robot arm, which handles the camera and ensures that the target is always within the image. The obtained results show the suitability of the proposed approach, adding a tracking algorithm to improve the performance of the leakage detection system. PMID:24113684
Talarico, Daria; Cinti, Stefano; Arduini, Fabiana; Amine, Aziz; Moscone, Danila; Palleschi, Giuseppe
2015-07-07
An automatable flow system for the continuous and long-term monitoring of the phosphate level has been developed using an amperometric detection method based on the use of a miniaturized sensor. This method is based on the monitoring of an electroactive complex obtained by the reaction between phosphate and molybdate that is consequently reduced at the electrode surface. The use of a screen-printed electrode modified with carbon black nanoparticles (CBNPs) leads to the quantification of the complex at low potential, because CBNPs are capable of electrocatalitically enhancing the phosphomolybdate complex reduction at +125 mV versus Ag/AgCl without fouling problems. The developed system also incorporates reagents and waste storage and is connected to a portable potentiostat for rapid detection and quantification of phosphate. Main analytical parameters, such as working potential, reagent concentration, type of cell, and flow rate, were evaluated and optimized. This system was characterized by a low detection limit (6 μM). Interference studies were carried out. Good recovery percentages comprised between 89 and 131.5% were achieved in different water sources, highlighting its suitability for field measurements.
An affordable modular vehicle radar for landmine and IED detection
NASA Astrophysics Data System (ADS)
Daniels, David; Curtis, Paul; Dittmer, Jon; Hunt, Nigel; Graham, Blair; Allan, Robert
2009-05-01
This paper describes a vehicle mounted 8-channel radar system suitable for buried landmine and IED detection. The system is designed to find Anti Tank (AT) landmines and buried Improvised Explosive Devices (IEDs). The radar uses field-proven ground penetrating radar sub-system modules and is scalable to 16, 32 or 64 channels, for covering greater swathe widths and for providing higher cross track resolution. This offers the capability of detecting smaller targets down to a minimum dimension of 100mm. The current rate of advance of the technology demonstrator is 10 kph; this can be increased to 20 kph where required. The data output is triggered via shaft encoder or via GPS and, for each forward increment; the data output is variable from a single byte per channel through to the 512 samples per channel. Trials using an autonomous vehicle, combined with a COFDM wireless link for data and telemetry back to a base station, have proven successful and the system architecture is described in this paper. The GPR array can be used as a standalone sensor or can be integrated with off-the-shelf software and a metal detection array.
Measurement technology of RF interference current in high current system
NASA Astrophysics Data System (ADS)
Zhao, Zhihua; Li, Jianxuan; Zhang, Xiangming; Zhang, Lei
2018-06-01
Current probe is a detection method commonly used in electromagnetic compatibility. With the development of power electronics technology, the power level of power conversion devices is constantly increasing, and the power current of the electric energy conversion device in the electromagnetic launch system can reach 10kA. Current probe conventionally used in EMC (electromagnetic compatibility) detection cannot meet the test requirements on high current system due to the magnetic saturation problem. The conventional high current sensor is also not suitable for the RF (Radio Frequency) interference current measurement in high current power device due to the high noise level in the output of active amplifier. In this paper, a passive flexible current probe based on Rogowski coil and matching resistance is proposed that can withstand high current and has low noise level, to solve the measurement problems of interference current in high current power converter. And both differential mode and common mode current detection can be easily carried out with the proposed probe because of the probe's flexible structure.
NASA Astrophysics Data System (ADS)
Tautz-Weinert, J.; Watson, S. J.
2016-09-01
Effective condition monitoring techniques for wind turbines are needed to improve maintenance processes and reduce operational costs. Normal behaviour modelling of temperatures with information from other sensors can help to detect wear processes in drive trains. In a case study, modelling of bearing and generator temperatures is investigated with operational data from the SCADA systems of more than 100 turbines. The focus is here on automated training and testing on a farm level to enable an on-line system, which will detect failures without human interpretation. Modelling based on linear combinations, artificial neural networks, adaptive neuro-fuzzy inference systems, support vector machines and Gaussian process regression is compared. The selection of suitable modelling inputs is discussed with cross-correlation analyses and a sensitivity study, which reveals that the investigated modelling techniques react in different ways to an increased number of inputs. The case study highlights advantages of modelling with linear combinations and artificial neural networks in a feedforward configuration.
Weakly electric fish for biomonitoring water quality.
Clausen, Juergen; van Wijk, Roeland; Albrecht, Henning
2012-06-01
Environmental pollution is a major issue that calls for suitable monitoring systems. The number of possible pollutants of municipal and industrial water grows annually as new chemicals are developed. Technical devices for pollutant detection are constructed in a way to detect a specific and known array of pollutants. Biological systems react to lethal or non-lethal environmental changes without pre-adjustment, and a wide variety have been employed as broad-range monitors for water quality. Weakly electric fish have proven particularly useful for the purpose of biomonitoring municipal and industrial waters. The frequency of their electric organ discharges directly correlates with the quality of the surrounding water and, in this way, concentrations of toxicants down to the nanomolar range have been successfully detected by these organisms. We have reviewed the literature on biomonitoring studies to date, comparing advantages and disadvantages of this test system and summarizing the lowest concentrations of various toxicants tested. Eighteen publications were identified investigating 35 different chemical substances and using six different species of weakly electric fish.
Why conventional detection methods fail in identifying the existence of contamination events.
Liu, Shuming; Li, Ruonan; Smith, Kate; Che, Han
2016-04-15
Early warning systems are widely used to safeguard water security, but their effectiveness has raised many questions. To understand why conventional detection methods fail to identify contamination events, this study evaluates the performance of three contamination detection methods using data from a real contamination accident and two artificial datasets constructed using a widely applied contamination data construction approach. Results show that the Pearson correlation Euclidean distance (PE) based detection method performs better for real contamination incidents, while the Euclidean distance method (MED) and linear prediction filter (LPF) method are more suitable for detecting sudden spike-like variation. This analysis revealed why the conventional MED and LPF methods failed to identify existence of contamination events. The analysis also revealed that the widely used contamination data construction approach is misleading. Copyright © 2016 Elsevier Ltd. All rights reserved.
Low-Complexity Noncoherent Signal Detection for Nanoscale Molecular Communications.
Li, Bin; Sun, Mengwei; Wang, Siyi; Guo, Weisi; Zhao, Chenglin
2016-01-01
Nanoscale molecular communication is a viable way of exchanging information between nanomachines. In this investigation, a low-complexity and noncoherent signal detection technique is proposed to mitigate the inter-symbol-interference (ISI) and additive noise. In contrast to existing coherent detection methods of high complexity, the proposed noncoherent signal detector is more practical when the channel conditions are hard to acquire accurately or hidden from the receiver. The proposed scheme employs the molecular concentration difference to detect the ISI corrupted signals and we demonstrate that it can suppress the ISI effectively. The difference in molecular concentration is a stable characteristic, irrespective of the diffusion channel conditions. In terms of complexity, by excluding matrix operations or likelihood calculations, the new detection scheme is particularly suitable for nanoscale molecular communication systems with a small energy budget or limited computation resource.
Piezoresistive effect of the carbon nanotube yarn embedded axially into the 3D braided composite
NASA Astrophysics Data System (ADS)
Ma, Xin; Cao, Xiaona
2018-06-01
A new method for monitoring 3D braided composite structure health in real time by embedding the carbon nanotube yarn, based on its piezoresistivity, in the composite axially has been designed. The experimental system for piezoresistive effect detection of the carbon nanotube yarn in the 3D braided composite was built, and the sensing characteristics has been analyzed for further research. Compared with other structural health monitoring methods, the monitoring technique with carbon nanotubes yarns is more suitable for internal damage detection immediately, in addition the strength of the composite can be increased by embedding carbon nanotubes yarns. This method can also be used for strain sensing, the development of intelligent materials and structure systems.
Borman, Christopher J.; Sullivan, B. Patrick; Eggleston, Carrick M.; Colberg, Patricia J. S.
2009-01-01
An evaluation of flow-injection analysis with chemiluminescence detection (FIA-CL) to quantify Fe2+(aq) in freshwaters was performed. Iron-coordinating and/or iron-reducing compounds, dissolved organic matter (DOM), and samples from two natural water systems were used to amend standard solutions of Fe2+(aq). Slopes of the response curves from ferrous iron standards (1 – 100 nM) were compared to the response curves of iron standards containing the amendments. Results suggest that FIA-CL is not suitable for systems containing ascorbate, hydroxylamine, cysteine or DOM. Little or no change in sensitivity occurred in solutions of oxalate and glycine or in natural waters with little organic matter. PMID:22408532
Collusion-Resistant Audio Fingerprinting System in the Modulated Complex Lapped Transform Domain
Garcia-Hernandez, Jose Juan; Feregrino-Uribe, Claudia; Cumplido, Rene
2013-01-01
Collusion-resistant fingerprinting paradigm seems to be a practical solution to the piracy problem as it allows media owners to detect any unauthorized copy and trace it back to the dishonest users. Despite the billionaire losses in the music industry, most of the collusion-resistant fingerprinting systems are devoted to digital images and very few to audio signals. In this paper, state-of-the-art collusion-resistant fingerprinting ideas are extended to audio signals and the corresponding parameters and operation conditions are proposed. Moreover, in order to carry out fingerprint detection using just a fraction of the pirate audio clip, block-based embedding and its corresponding detector is proposed. Extensive simulations show the robustness of the proposed system against average collusion attack. Moreover, by using an efficient Fast Fourier Transform core and standard computer machines it is shown that the proposed system is suitable for real-world scenarios. PMID:23762455
Codony, Francesc; Pérez, Leonardo Martín; Adrados, Bárbara; Agustí, Gemma; Fittipaldi, Mariana; Morató, Jordi
2012-01-01
Culture-based methods for fecal indicator microorganisms are the standard protocol to assess potential health risk from drinking water systems. However, these traditional fecal indicators are inappropriate surrogates for disinfection-resistant fecal pathogens and the indigenous pathogens that grow in drinking water systems. There is now a range of molecular-based methods, such as quantitative PCR, which allow detection of a variety of pathogens and alternative indicators. Hence, in addition to targeting total Escherichia coli (i.e., dead and alive) for the detection of fecal pollution, various amoebae may be suitable to indicate the potential presence of pathogenic amoeba-resisting microorganisms, such as Legionellae. Therefore, monitoring amoeba levels by quantitative PCR could be a useful tool for directly and indirectly evaluating health risk and could also be a complementary approach to current microbial quality control strategies for drinking water systems.
Ben Mansour, Khaireddine; Rezzoug, Nasser; Gorce, Philippe
2015-10-01
The purpose of this paper was to determine which types of inertial sensors and which advocated locations should be used for reliable and accurate gait event detection and temporal parameter assessment in normal adults. In addition, we aimed to remove the ambiguity found in the literature of the definition of the initial contact (IC) from the lumbar accelerometer. Acceleration and angular velocity data was gathered from the lumbar region and the distal edge of each shank. This data was evaluated in comparison to an instrumented treadmill and an optoelectronic system during five treadmill speed sessions. The lumbar accelerometer showed that the peak of the anteroposterior component was the most accurate for IC detection. Similarly, the valley that followed the peak of the vertical component was the most precise for terminal contact (TC) detection. Results based on ANOVA and Tukey tests showed that the set of inertial methods was suitable for temporal gait assessment and gait event detection in able-bodied subjects. For gait event detection, an exception was found with the shank accelerometer. The tool was suitable for temporal parameters assessment, despite the high root mean square error on the detection of IC (RMSEIC) and TC (RMSETC). The shank gyroscope was found to be as accurate as the kinematic method since the statistical tests revealed no significant difference between the two techniques for the RMSE off all gait events and temporal parameters. The lumbar and shank accelerometers were the most accurate alternative to the shank gyroscope for gait event detection and temporal parameters assessment, respectively. Copyright © 2015. Published by Elsevier B.V.
Molecular gated nanoporous anodic alumina for the detection of cocaine
NASA Astrophysics Data System (ADS)
Ribes, Àngela; Xifré-Pérez, Elisabet; Aznar, Elena; Sancenón, Félix; Pardo, Teresa; Marsal, Lluís F.; Martínez-Máñez, Ramόn
2016-12-01
We present herein the use of nanoporous anodic alumina (NAA) as a suitable support to implement “molecular gates” for sensing applications. In our design, a NAA support is loaded with a fluorescent reporter (rhodamine B) and functionalized with a short single-stranded DNA. Then pores are blocked by the subsequent hybridisation of a specific cocaine aptamer. The response of the gated material was studied in aqueous solution. In a typical experiment, the support was immersed in hybridisation buffer solution in the absence or presence of cocaine. At certain times, the release of rhodamine B from pore voids was measured by fluorescence spectroscopy. The capped NAA support showed poor cargo delivery, but presence of cocaine in the solution selectively induced rhodamine B release. By this simple procedure a limit of detection as low as 5 × 10-7 M was calculated for cocaine. The gated NAA was successfully applied to detect cocaine in saliva samples and the possible re-use of the nanostructures was assessed. Based on these results, we believe that NAA could be a suitable support to prepare optical gated probes with a synergic combination of the favourable features of selected gated sensing systems and NAA.
Molecular gated nanoporous anodic alumina for the detection of cocaine.
Ribes, Àngela; Xifré-Pérez, Elisabet; Aznar, Elena; Sancenón, Félix; Pardo, Teresa; Marsal, Lluís F; Martínez-Máñez, Ramόn
2016-12-07
We present herein the use of nanoporous anodic alumina (NAA) as a suitable support to implement "molecular gates" for sensing applications. In our design, a NAA support is loaded with a fluorescent reporter (rhodamine B) and functionalized with a short single-stranded DNA. Then pores are blocked by the subsequent hybridisation of a specific cocaine aptamer. The response of the gated material was studied in aqueous solution. In a typical experiment, the support was immersed in hybridisation buffer solution in the absence or presence of cocaine. At certain times, the release of rhodamine B from pore voids was measured by fluorescence spectroscopy. The capped NAA support showed poor cargo delivery, but presence of cocaine in the solution selectively induced rhodamine B release. By this simple procedure a limit of detection as low as 5 × 10 -7 M was calculated for cocaine. The gated NAA was successfully applied to detect cocaine in saliva samples and the possible re-use of the nanostructures was assessed. Based on these results, we believe that NAA could be a suitable support to prepare optical gated probes with a synergic combination of the favourable features of selected gated sensing systems and NAA.
Molecular gated nanoporous anodic alumina for the detection of cocaine
Ribes, Àngela; Xifré -Pérez, Elisabet; Aznar, Elena; Sancenón, Félix; Pardo, Teresa; Marsal, Lluís F.; Martínez-Máñez, Ramόn
2016-01-01
We present herein the use of nanoporous anodic alumina (NAA) as a suitable support to implement “molecular gates” for sensing applications. In our design, a NAA support is loaded with a fluorescent reporter (rhodamine B) and functionalized with a short single-stranded DNA. Then pores are blocked by the subsequent hybridisation of a specific cocaine aptamer. The response of the gated material was studied in aqueous solution. In a typical experiment, the support was immersed in hybridisation buffer solution in the absence or presence of cocaine. At certain times, the release of rhodamine B from pore voids was measured by fluorescence spectroscopy. The capped NAA support showed poor cargo delivery, but presence of cocaine in the solution selectively induced rhodamine B release. By this simple procedure a limit of detection as low as 5 × 10−7 M was calculated for cocaine. The gated NAA was successfully applied to detect cocaine in saliva samples and the possible re-use of the nanostructures was assessed. Based on these results, we believe that NAA could be a suitable support to prepare optical gated probes with a synergic combination of the favourable features of selected gated sensing systems and NAA. PMID:27924950
Lasić, Lejla; Lojo-Kadrić, Naida; Silajdžić, Elma; Pojskić, Lejla; Hadžiselimović, Rifat; Pojskić, Naris
2013-01-01
There are two major theories for inheritance of Rh blood group system: Fisher – Race theory and Wiener theory. Aim of this study was identifying frequency of RHDCE alleles in Bosnian – Herzegovinian population and introduction of this method in screening for Rh phenotype in B&H since this type of analysis was not used for blood typing in B&H before. Rh blood group was typed by Polymerase Chain Reaction, using the protocols and primers previously established by other authors, then carrying out electrophoresis in 2-3% agarose gel. Percentage of Rh positive individuals in our sample is 84.48%, while the percentage of Rh negative individuals is 15.52%. Inter-rater agreement statistic showed perfect agreement (K=1) between the results of Rh blood system detection based on serological and molecular-genetics methods. In conclusion, molecular – genetic methods are suitable for prenatal genotyping and specific cases while standard serological method is suitable for high-throughput of samples. PMID:23448604
A Three-Dimensional Receiver Operator Characteristic Surface Diagnostic Metric
NASA Technical Reports Server (NTRS)
Simon, Donald L.
2011-01-01
Receiver Operator Characteristic (ROC) curves are commonly applied as metrics for quantifying the performance of binary fault detection systems. An ROC curve provides a visual representation of a detection system s True Positive Rate versus False Positive Rate sensitivity as the detection threshold is varied. The area under the curve provides a measure of fault detection performance independent of the applied detection threshold. While the standard ROC curve is well suited for quantifying binary fault detection performance, it is not suitable for quantifying the classification performance of multi-fault classification problems. Furthermore, it does not provide a measure of diagnostic latency. To address these shortcomings, a novel three-dimensional receiver operator characteristic (3D ROC) surface metric has been developed. This is done by generating and applying two separate curves: the standard ROC curve reflecting fault detection performance, and a second curve reflecting fault classification performance. A third dimension, diagnostic latency, is added giving rise to 3D ROC surfaces. Applying numerical integration techniques, the volumes under and between the surfaces are calculated to produce metrics of the diagnostic system s detection and classification performance. This paper will describe the 3D ROC surface metric in detail, and present an example of its application for quantifying the performance of aircraft engine gas path diagnostic methods. Metric limitations and potential enhancements are also discussed
Noise detection in heart sound recordings.
Zia, Mohammad K; Griffel, Benjamin; Fridman, Vladimir; Saponieri, Cesare; Semmlow, John L
2011-01-01
Coronary artery disease (CAD) is the leading cause of death in the United States. Although progression of CAD can be controlled using drugs and diet, it is usually detected in advanced stages when invasive treatment is required. Current methods to detect CAD are invasive and/or costly, hence not suitable as a regular screening tool to detect CAD in early stages. Currently, we are developing a noninvasive and cost-effective system to detect CAD using the acoustic approach. This method identifies sounds generated by turbulent flow through partially narrowed coronary arteries to detect CAD. The limiting factor of this method is sensitivity to noises commonly encountered in the clinical setting. Because the CAD sounds are faint, these noises can easily obscure the CAD sounds and make detection impossible. In this paper, we propose a method to detect and eliminate noise encountered in the clinical setting using a reference channel. We show that our method is effective in detecting noise, which is essential to the success of the acoustic approach.
Fluorescent discrimination between traces of chemical warfare agents and their mimics.
Díaz de Greñu, Borja; Moreno, Daniel; Torroba, Tomás; Berg, Alexander; Gunnars, Johan; Nilsson, Tobias; Nyman, Rasmus; Persson, Milton; Pettersson, Johannes; Eklind, Ida; Wästerby, Pär
2014-03-19
An array of fluorogenic probes is able to discriminate between nerve agents, sarin, soman, tabun, VX and their mimics, in water or organic solvent, by qualitative fluorescence patterns and quantitative multivariate analysis, thus making the system suitable for the in-the-field detection of traces of chemical warfare agents as well as to differentiate between the real nerve agents and other related compounds.
Leal, Yenny; Gonzalez-Abril, Luis; Lorencio, Carol; Bondia, Jorge; Vehi, Josep
2013-07-01
Support vector machines (SVMs) are an attractive option for detecting correct and incorrect measurements in real-time continuous glucose monitoring systems (RTCGMSs), because their learning mechanism can introduce a postprocessing strategy for imbalanced datasets. The proposed SVM considers the geometric mean to obtain a more balanced performance between sensitivity and specificity. To test this approach, 23 critically ill patients receiving insulin therapy were monitored over 72 h using an RTCGMS, and a dataset of 537 samples, classified according to International Standards Organization (ISO) criteria (372 correct and 165 incorrect measurements), was obtained. The results obtained were promising for patients with septic shock or with sepsis, for which the proposed system can be considered as reliable. However, this approach cannot be considered suitable for patients without sepsis.
Single-Frequency Ultrasound-Based Respiration Rate Estimation with Smartphones
Wei, Jing
2018-01-01
Respiration monitoring is helpful in disease prevention and diagnosis. Traditional respiration monitoring requires users to wear devices on their bodies, which is inconvenient for them. In this paper, we aim to design a noncontact respiration rate detection system utilizing off-the-shelf smartphones. We utilize the single-frequency ultrasound as the media to detect the respiration activity. By analyzing the ultrasound signals received by the built-in microphone sensor in a smartphone, our system can derive the respiration rate of the user. The advantage of our method is that the transmitted signal is easy to generate and the signal analysis is simple, which has lower power consumption and thus is suitable for long-term monitoring in daily life. The experimental result shows that our system can achieve accurate respiration rate estimation under various scenarios. PMID:29853985
NASA Astrophysics Data System (ADS)
De Biasio, Martin; Arnold, Thomas; McGunnigle, Gerald; Kraft, Martin; Leitner, Raimund; Balthasar, Dirk; Rehrmann, Volker
2011-06-01
Recycling of glass requires the removal of specialist glasses, such as fireproof and mineral glasses, and glass ceramics, which are regarded as contaminants. The sorting must take place before melting for efficient glass recycling. Here, we demonstrate the feasibility of a real-time Raman mapping system for detecting and discriminating a range of industrially relevant glass contaminants in recovered glass streams. The components used are suitable for industrial conditions and the chemometric model is robust against imaging geometry and excitation intensity. The proposed approach is a novel alternative to established glass sorting sensors.
Method and Apparatus for Concentrating Vapors for Analysis
Grate, Jay W.; Baldwin, David L.; Anheier, Jr., Norman C.
2008-10-07
An apparatus and method are disclosed for pre-concentrating gaseous vapors for analysis. The invention finds application in conjunction with, e.g., analytical instruments where low detection limits for gaseous vapors are desirable. Vapors sorbed and concentrated within the bed of the apparatus can be thermally desorbed achieving at least partial separation of vapor mixtures. The apparatus is suitable, e.g., for preconcentration and sample injection, and provides greater resolution of peaks for vapors within vapor mixtures, yielding detection levels that are 10-10,000 times better than for direct sampling and analysis systems. Features are particularly useful for continuous unattended monitoring applications.
Use of the Real Time xCelligence System for Purposes of Medical Microbiology.
Junka, Adam Feliks; Janczura, Adriana; Smutnicka, Danuta; Mączyńska, Beata; Anna, Secewicz; Nowicka, Joanna; Bartoszewicz, Marzenna; Gościniak, Grażyna
2012-09-28
Roche's xCelligence impedance-measuring instrument is one of a few commercially available systems of such type. According to the best knowledge of authors, instrument was tested so far only for eukaryotic cell research. The aim of this work was to estimate xCELLigence suitability for the microbiological tests, including (i) measurement of morphological changes in eukaryotic cells as a result of bacterial toxin activity, (ii) measurement of bacterial biofilm formation and (iii) impact of antiseptics on the biofilm structure. To test the infuence of bacterial LT enterotoxin on eukaryotic cell lines, Chinese Hamster Ovary (CHO) cell line and reference strain Escherichia coli ATTC 35401 were used. To investigate Roche's instrument ability to measure biofilm formation and impact of antiseptics on its development, Staphylococcus aureus ATTC6538 reference strain was used. The data generated during the experiments indicate excellent ability of xCelligence instrument to detect cytopathic effect caused by bacterial LT endotoxin and to detect staphylococcal biofilm formation. However, interpretation of the results obtained during real-time measurement of antiseptic's bactericidal activity against staphylococcal biofilm, caused many difficulties. xCelligence instrument can be used for real-time monitoring of morphological changes in CHO cells treated with bacterial LT enterotoxin and for real-time measurement of staphylococcal biofilm formation in vitro. Further investigation is necessary to confirm suitability of system to analyze antiseptic's antimicrobial activity against biofilm in vitro.
Robust Road Condition Detection System Using In-Vehicle Standard Sensors.
Castillo Aguilar, Juan Jesús; Cabrera Carrillo, Juan Antonio; Guerra Fernández, Antonio Jesús; Carabias Acosta, Enrique
2015-12-19
The appearance of active safety systems, such as Anti-lock Braking System, Traction Control System, Stability Control System, etc., represents a major evolution in road safety. In the automotive sector, the term vehicle active safety systems refers to those whose goal is to help avoid a crash or to reduce the risk of having an accident. These systems safeguard us, being in continuous evolution and incorporating new capabilities continuously. In order for these systems and vehicles to work adequately, they need to know some fundamental information: the road condition on which the vehicle is circulating. This early road detection is intended to allow vehicle control systems to act faster and more suitably, thus obtaining a substantial advantage. In this work, we try to detect the road condition the vehicle is being driven on, using the standard sensors installed in commercial vehicles. Vehicle models were programmed in on-board systems to perform real-time estimations of the forces of contact between the wheel and road and the speed of the vehicle. Subsequently, a fuzzy logic block is used to obtain an index representing the road condition. Finally, an artificial neural network was used to provide the optimal slip for each surface. Simulations and experiments verified the proposed method.
Robust Road Condition Detection System Using In-Vehicle Standard Sensors
Castillo Aguilar, Juan Jesús; Cabrera Carrillo, Juan Antonio; Guerra Fernández, Antonio Jesús; Carabias Acosta, Enrique
2015-01-01
The appearance of active safety systems, such as Anti-lock Braking System, Traction Control System, Stability Control System, etc., represents a major evolution in road safety. In the automotive sector, the term vehicle active safety systems refers to those whose goal is to help avoid a crash or to reduce the risk of having an accident. These systems safeguard us, being in continuous evolution and incorporating new capabilities continuously. In order for these systems and vehicles to work adequately, they need to know some fundamental information: the road condition on which the vehicle is circulating. This early road detection is intended to allow vehicle control systems to act faster and more suitably, thus obtaining a substantial advantage. In this work, we try to detect the road condition the vehicle is being driven on, using the standard sensors installed in commercial vehicles. Vehicle models were programmed in on-board systems to perform real-time estimations of the forces of contact between the wheel and road and the speed of the vehicle. Subsequently, a fuzzy logic block is used to obtain an index representing the road condition. Finally, an artificial neural network was used to provide the optimal slip for each surface. Simulations and experiments verified the proposed method. PMID:26703605
Shift-, rotation-, and scale-invariant shape recognition system using an optical Hough transform
NASA Astrophysics Data System (ADS)
Schmid, Volker R.; Bader, Gerhard; Lueder, Ernst H.
1998-02-01
We present a hybrid shape recognition system with an optical Hough transform processor. The features of the Hough space offer a separate cancellation of distortions caused by translations and rotations. Scale invariance is also provided by suitable normalization. The proposed system extends the capabilities of Hough transform based detection from only straight lines to areas bounded by edges. A very compact optical design is achieved by a microlens array processor accepting incoherent light as direct optical input and realizing the computationally expensive connections massively parallel. Our newly developed algorithm extracts rotation and translation invariant normalized patterns of bright spots on a 2D grid. A neural network classifier maps the 2D features via a nonlinear hidden layer onto the classification output vector. We propose initialization of the connection weights according to regions of activity specifically assigned to each neuron in the hidden layer using a competitive network. The presented system is designed for industry inspection applications. Presently we have demonstrated detection of six different machined parts in real-time. Our method yields very promising detection results of more than 96% correctly classified parts.
Anazawa, Takashi; Uchiho, Yuichi; Yokoi, Takahide; Chalkidis, George; Yamazaki, Motohiro
2017-06-27
A five-color fluorescence-detection system for eight-channel plastic-microchip electrophoresis was developed. In the eight channels (with effective electrophoretic lengths of 10 cm), single-stranded DNA fragments were separated (with single-base resolution up to 300 bases within 10 min), and seventeen-loci STR genotyping for forensic human identification was successfully demonstrated. In the system, a side-entry laser beam is passed through the eight channels (eight A channels), with alternately arrayed seven sacrificial channels (seven B channels), by a technique called "side-entry laser-beam zigzag irradiation." Laser-induced fluorescence from the eight A channels and Raman-scattered light from the seven B channels are then simultaneously, uniformly, and spectroscopically detected, in the direction perpendicular to the channel array plane, through a transmission grating and a CCD camera. The system is therefore simple and highly sensitive. Because the microchip is fabricated by plastic-injection molding, it is inexpensive and disposable and thus suitable for actual use in various fields.
Acoustic-sensor-based detection of damage in composite aircraft structures
NASA Astrophysics Data System (ADS)
Foote, Peter; Martin, Tony; Read, Ian
2004-03-01
Acoustic emission detection is a well-established method of locating and monitoring crack development in metal structures. The technique has been adapted to test facilities for non-destructive testing applications. Deployment as an operational or on-line automated damage detection technology in vehicles is posing greater challenges. A clear requirement of potential end-users of such systems is a level of automation capable of delivering low-level diagnosis information. The output from the system is in the form of "go", "no-go" indications of structural integrity or immediate maintenance actions. This level of automation requires significant data reduction and processing. This paper describes recent trials of acoustic emission detection technology for the diagnosis of damage in composite aerospace structures. The technology comprises low profile detection sensors using piezo electric wafers encapsulated in polymer film ad optical sensors. Sensors are bonded to the structure"s surface and enable acoustic events from the loaded structure to be located by triangulation. Instrumentation has been enveloped to capture and parameterise the sensor data in a form suitable for low-bandwidth storage and transmission.
Smart sensing surveillance video system
NASA Astrophysics Data System (ADS)
Hsu, Charles; Szu, Harold
2016-05-01
An intelligent video surveillance system is able to detect and identify abnormal and alarming situations by analyzing object movement. The Smart Sensing Surveillance Video (S3V) System is proposed to minimize video processing and transmission, thus allowing a fixed number of cameras to be connected on the system, and making it suitable for its applications in remote battlefield, tactical, and civilian applications including border surveillance, special force operations, airfield protection, perimeter and building protection, and etc. The S3V System would be more effective if equipped with visual understanding capabilities to detect, analyze, and recognize objects, track motions, and predict intentions. In addition, alarm detection is performed on the basis of parameters of the moving objects and their trajectories, and is performed using semantic reasoning and ontologies. The S3V System capabilities and technologies have great potential for both military and civilian applications, enabling highly effective security support tools for improving surveillance activities in densely crowded environments. It would be directly applicable to solutions for emergency response personnel, law enforcement, and other homeland security missions, as well as in applications requiring the interoperation of sensor networks with handheld or body-worn interface devices.
NASA Astrophysics Data System (ADS)
Qin, Feihu; Hu, Juntao; Wang, Huanqin; Gui, Huaqiao; Liu, Jianguo; Lü, Liang; Kong, Deyi; Zhang, Jian; Han, Xia; Wang, Tianli
2017-10-01
An all-fiber structure detection system based on single photon detection technique(SPDT) has been developed to measure the ultra-low turbidity ofliquids. To assure the measurement accuracy,the total intensity of transmission light has been detected and quantified as number of photons by avalanche photodiode (APD) which has the advantage of high sensitivity.A fresh all-fiber structure optical fiber probe based on SPDT is applied in the system to reduce the volume and fluctuation of traditional transmission-light measurement system,in which the all-fiber structure probe is used to delivery and collection of transmission light.On the basis of Beer-Lambert (B-L) transmission law,a test system has been established and carried out a series of experiments.By combining B-Llaw with the principle of SPDT,a novel model for detecting turbidity has been proposed to explain the experimental results.The results have shown a well exponential relationship over the range of 0.01-1NTU (Nephelometric Turbidity Units).It also has showna good linear relationship with a resolution as high as 0.01NTUin the range of 0.01-0.09 NTU.When it is 1 secondofthe sampling time,the mean error of measurement result can be controlled within 5% of full scale.In addition,the new detection structure proposed in this paper, which makes the system more compact and more suitable in the small special space.
Hernández, Marta; Rodríguez-Lázaro, David; Esteve, Teresa; Prat, Salomé; Pla, Maria
2003-12-15
Commercialization of several genetically modified crops has been approved worldwide to date. Uniplex polymerase chain reaction (PCR)-based methods to identify these different insertion events have been developed, but their use in the analysis of all commercially available genetically modified organisms (GMOs) is becoming progressively insufficient. These methods require a large number of assays to detect all possible GMOs present in the sample and thereby the development of multiplex PCR systems using combined probes and primers targeted to sequences specific to various GMOs is needed for detection of this increasing number of GMOs. Here we report on the development of a multiplex real-time PCR suitable for multiple GMO identification, based on the intercalating dye SYBR Green I and the analysis of the melting curves of the amplified products. Using this method, different amplification products specific for Maximizer 176, Bt11, MON810, and GA21 maize and for GTS 40-3-2 soybean were obtained and identified by their specific Tm. We have combined amplification of these products in a number of multiplex reactions and show the suitability of the methods for identification of GMOs with a sensitivity of 0.1% in duplex reactions. The described methods offer an economic and simple alternative to real-time PCR systems based on sequence-specific probes (i.e., TaqMan chemistry). These methods can be used as selection tests and further optimized for uniplex GMO quantification.
Obscenity detection using haar-like features and Gentle Adaboost classifier.
Mustafa, Rashed; Min, Yang; Zhu, Dingju
2014-01-01
Large exposure of skin area of an image is considered obscene. This only fact may lead to many false images having skin-like objects and may not detect those images which have partially exposed skin area but have exposed erotogenic human body parts. This paper presents a novel method for detecting nipples from pornographic image contents. Nipple is considered as an erotogenic organ to identify pornographic contents from images. In this research Gentle Adaboost (GAB) haar-cascade classifier and haar-like features used for ensuring detection accuracy. Skin filter prior to detection made the system more robust. The experiment showed that, considering accuracy, haar-cascade classifier performs well, but in order to satisfy detection time, train-cascade classifier is suitable. To validate the results, we used 1198 positive samples containing nipple objects and 1995 negative images. The detection rates for haar-cascade and train-cascade classifiers are 0.9875 and 0.8429, respectively. The detection time for haar-cascade is 0.162 seconds and is 0.127 seconds for train-cascade classifier.
Identification of suitable sites for mountain ginseng cultivation using GIS and geo-temperature.
Kang, Hag Mo; Choi, Soo Im; Kim, Hyun
2016-01-01
This study was conducted to explore an accurate site identification technique using a geographic information system (GIS) and geo-temperature (gT) for locating suitable sites for growing cultivated mountain ginseng (CMG; Panax ginseng), which is highly sensitive to the environmental conditions in which it grows. The study site was Jinan-gun, South Korea. The spatial resolution for geographic data was set at 10 m × 10 m, and the temperatures for various climatic factors influencing CMG growth were calculated by averaging the 3-year temperatures obtained from the automatic weather stations of the Korea Meteorological Administration. Identification of suitable sites for CMG cultivation was undertaken using both a conventional method and a new method, in which the gT was added as one of the most important factors for crop cultivation. The results yielded by the 2 methods were then compared. When the gT was added as an additional factor (new method), the proportion of suitable sites identified decreased by 0.4 % compared with the conventional method. However, the proportion matching real CMG cultivation sites increased by 3.5 %. Moreover, only 68.2 % corresponded with suitable sites identified using the conventional factors; i.e., 31.8 % were newly detected suitable sites. The accuracy of GIS-based identification of suitable CMG cultivation sites improved by applying the temperature factor (i.e., gT) in addition to the conventionally used factors.
Final Overview of ACES Simulation for Evaluation SARP Well-Clear Definitions
NASA Technical Reports Server (NTRS)
Santiago, Confesor; Johnson, Marcus A.; Isaacson, Doug; Hershey, David
2014-01-01
The UAS in the NAS project is studying the minimum operational performance standards for unmanned aerial systems (UAS's) detect-and-avoid (DAA) system in order to operate in the National Airspace System. The DoD's Science and research Panel (SARP) Well-Clear Workshop is investigating the time and spatial boundary at which an UAS violates well-clear. NASA is supporting this effort through use of its Airspace Concept Evaluation System (ACES) simulation platform. This briefing presents the final results to the SARP, which will be used to judge the three candidate well-clear definitions, and for the selection of the most operationally suitable option.
Vince, L; Kleter, G A; Kostov, K; Pfeiffer, D U; Guitian, J
2018-04-20
A facultative post market monitoring of potential health impacts of genetically modified (GM) feedstuffs on livestock consuming these feeds after pre-market risk assessment is under ongoing consideration. Within the IPAFEED database, scientific studies on health effects beyond performance in livestock and the results of a systematic search for evidence of outcome effects due to GM feed are consolidated. These outcomes were reviewed and checked for consistency in order to identify plausible syndromes suitable for conducting surveillance. The 24 selected studies showed no consistent changes in any health parameter. There were no repeated studies in any species by GM crop type and animal species. As such, there is insufficient evidence to inform the design of surveillance systems for detecting known adverse effects. Animal health surveillance systems have been proposed for the post market monitoring of potential adverse effects in animals. Such systems were evaluated for their applicability to the detection of hypothetical adverse effects and their strengths and weaknesses to detect syndromes of concern are presented. For known adverse effects, applied controlled post-market studies may yield conclusive and high-quality evidence. For detecting unknown adverse effects, the use of existing surveillance systems may still be of interest. A simulation tool developed within the project can be adapted and applied to existing surveillance systems to explore their applicability to the detection of potential adverse effects of GM feed. Copyright © 2018. Published by Elsevier Ltd.
NASA Astrophysics Data System (ADS)
Gwitira, Isaiah; Murwira, Amon; Zengeya, Fadzai M.; Shekede, Munyaradzi Davis
2018-02-01
Malaria remains a major public health problem and a principal cause of morbidity and mortality in most developing countries. Although malaria still presents health problems, significant successes have been recorded in reducing deaths resulting from the disease. As malaria transmission continues to decline, control interventions will increasingly depend on the ability to define high-risk areas known as malaria hotspots. Therefore, there is urgent need to use geospatial tools such as geographic information system to detect spatial patterns of malaria and delineate disease hot spots for better planning and management. Thus, accurate mapping and prediction of seasonality of malaria hotspots is an important step towards developing strategies for effective malaria control. In this study, we modelled seasonal malaria hotspots as a function of habitat suitability of Anopheles arabiensis (A. Arabiensis) as a first step towards predicting likely seasonal malaria hotspots that could provide guidance in targeted malaria control. We used Geographical information system (GIS) and spatial statistic methods to identify seasonal hotspots of malaria cases at the country level. In order to achieve this, we first determined the spatial distribution of seasonal malaria hotspots using the Getis Ord Gi* statistic based on confirmed positive malaria cases recorded at health facilities in Zimbabwe over four years (1996-1999). We then used MAXENT technique to model habitat suitability of A. arabiensis from presence data collected from 1990 to 2002 based on bioclimatic variables and altitude. Finally, we used autologistic regression to test the extent to which malaria hotspots can be predicted using A. arabiensis habitat suitability. Our results show that A. arabiensis habitat suitability consistently and significantly (p < 0.05) predicts malaria hotspots from 1996 to 1999. Overall, our results show that malaria hotspots can be predicted using A. arabiensis habitat suitability, suggesting the possibility of developing models for malaria early warning based on vector habitat suitability.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martinenghi, E., E-mail: edoardo.martinenghi@polimi.it; Di Sieno, L.; Contini, D.
2016-07-15
We present the design and preliminary characterization of the first detection module based on Silicon Photomultiplier (SiPM) tailored for single-photon timing applications. The aim of this work is to demonstrate, thanks to the design of a suitable module, the possibility to easily exploit SiPM in many applications as an interesting detector featuring large active area, similarly to photomultipliers tubes, but keeping the advantages of solid state detectors (high quantum efficiency, low cost, compactness, robustness, low bias voltage, and insensitiveness to magnetic field). The module integrates a cooled SiPM with a total photosensitive area of 1 mm{sup 2} together with themore » suitable avalanche signal read-out circuit, the signal conditioning, the biasing electronics, and a Peltier cooler driver for thermal stabilization. It is able to extract the single-photon timing information with resolution better than 100 ps full-width at half maximum. We verified the effective stabilization in response to external thermal perturbations, thus proving the complete insensitivity of the module to environment temperature variations, which represents a fundamental parameter to profitably use the instrument for real-field applications. We also characterized the single-photon timing resolution, the background noise due to both primary dark count generation and afterpulsing, the single-photon detection efficiency, and the instrument response function shape. The proposed module can become a reliable and cost-effective building block for time-correlated single-photon counting instruments in applications requiring high collection capability of isotropic light and detection efficiency (e.g., fluorescence decay measurements or time-domain diffuse optics systems).« less
Gandolla, Marta; Ferrante, Simona; Casellato, Claudia; Ferrigno, Giancarlo; Molteni, Franco; Martegani, Alberto; Frattini, Tiziano; Pedrocchi, Alessandra
2011-10-01
Functional Electrical Stimulation (FES) is a well known clinical rehabilitation procedure, however the neural mechanisms that underlie this treatment at Central Nervous System (CNS) level are still not completely understood. Functional magnetic resonance imaging (fMRI) is a suitable tool to investigate effects of rehabilitative treatments on brain plasticity. Moreover, monitoring the effective executed movement is needed to correctly interpret activation maps, most of all in neurological patients where required motor tasks could be only partially accomplished. The proposed experimental set-up includes a 1.5 T fMRI scanner, a motion capture system to acquire kinematic data, and an electro-stimulation device. The introduction of metallic devices and of stimulation current in the MRI room could affect fMRI acquisitions so as to prevent a reliable activation maps analysis. What we are interested in is that the Blood Oxygenation Level Dependent (BOLD) signal, marker of neural activity, could be detected within a given experimental condition and set-up. In this paper we assess temporal Signal to Noise Ratio (SNR) as image quality index. BOLD signal change is about 1-2% as revealed by a 1.5 T scanner. This work demonstrates that, with this innovative set-up, in the main cortical sensorimotor regions 1% BOLD signal change can be detected at least in the 93% of the sub-volumes, and almost 100% of the sub-volumes are suitable for 2% signal change detection. The integrated experimental set-up will therefore allows to detect FES induced movements fMRI maps simultaneously with kinematic acquisitions so as to investigate FES-based rehabilitation treatments contribution at CNS level. Copyright © 2011 IPEM. Published by Elsevier Ltd. All rights reserved.
Is it feasible to estimate radiosonde biases from interlaced measurements?
NASA Astrophysics Data System (ADS)
Kremser, Stefanie; Tradowsky, Jordis S.; Rust, Henning W.; Bodeker, Greg E.
2018-05-01
Upper-air measurements of essential climate variables (ECVs), such as temperature, are crucial for climate monitoring and climate change detection. Because of the internal variability of the climate system, many decades of measurements are typically required to robustly detect any trend in the climate data record. It is imperative for the records to be temporally homogeneous over many decades to confidently estimate any trend. Historically, records of upper-air measurements were primarily made for short-term weather forecasts and as such are seldom suitable for studying long-term climate change as they lack the required continuity and homogeneity. Recognizing this, the Global Climate Observing System (GCOS) Reference Upper-Air Network (GRUAN) has been established to provide reference-quality measurements of climate variables, such as temperature, pressure, and humidity, together with well-characterized and traceable estimates of the measurement uncertainty. To ensure that GRUAN data products are suitable to detect climate change, a scientifically robust instrument replacement strategy must always be adopted whenever there is a change in instrumentation. By fully characterizing any systematic differences between the old and new measurement system a temporally homogeneous data series can be created. One strategy is to operate both the old and new instruments in tandem for some overlap period to characterize any inter-instrument biases. However, this strategy can be prohibitively expensive at measurement sites operated by national weather services or research institutes. An alternative strategy that has been proposed is to alternate between the old and new instruments, so-called interlacing, and then statistically derive the systematic biases between the two instruments. Here we investigate the feasibility of such an approach specifically for radiosondes, i.e. flying the old and new instruments on alternating days. Synthetic data sets are used to explore the applicability of this statistical approach to radiosonde change management.
Evaluation of a Multivariate Syndromic Surveillance System for West Nile Virus.
Faverjon, Céline; Andersson, M Gunnar; Decors, Anouk; Tapprest, Jackie; Tritz, Pierre; Sandoz, Alain; Kutasi, Orsolya; Sala, Carole; Leblond, Agnès
2016-06-01
Various methods are currently used for the early detection of West Nile virus (WNV) but their outputs are not quantitative and/or do not take into account all available information. Our study aimed to test a multivariate syndromic surveillance system to evaluate if the sensitivity and the specificity of detection of WNV could be improved. Weekly time series data on nervous syndromes in horses and mortality in both horses and wild birds were used. Baselines were fitted to the three time series and used to simulate 100 years of surveillance data. WNV outbreaks were simulated and inserted into the baselines based on historical data and expert opinion. Univariate and multivariate syndromic surveillance systems were tested to gauge how well they detected the outbreaks; detection was based on an empirical Bayesian approach. The systems' performances were compared using measures of sensitivity, specificity, and area under receiver operating characteristic curve (AUC). When data sources were considered separately (i.e., univariate systems), the best detection performance was obtained using the data set of nervous symptoms in horses compared to those of bird and horse mortality (AUCs equal to 0.80, 0.75, and 0.50, respectively). A multivariate outbreak detection system that used nervous symptoms in horses and bird mortality generated the best performance (AUC = 0.87). The proposed approach is suitable for performing multivariate syndromic surveillance of WNV outbreaks. This is particularly relevant, given that a multivariate surveillance system performed better than a univariate approach. Such a surveillance system could be especially useful in serving as an alert for the possibility of human viral infections. This approach can be also used for other diseases for which multiple sources of evidence are available.
Intensity-based readout of resonant-waveguide grating biosensors: Systems and nanostructures
NASA Astrophysics Data System (ADS)
Paulsen, Moritz; Jahns, Sabrina; Gerken, Martina
2017-09-01
Resonant waveguide gratings (RWG) - also called photonic crystal slabs (PCS) - have been established as reliable optical transducers for label-free biochemical assays as well as for cell-based assays. Current readout systems are based on mechanical scanning and spectrometric measurements with system sizes suitable for laboratory equipment. Here, we review recent progress in compact intensity-based readout systems for point-of-care (POC) applications. We briefly introduce PCSs as sensitive optical transducers and introduce different approaches for intensity-based readout systems. Photometric measurements have been realized with a simple combination of a light source and a photodetector. Recently a 96-channel, intensity-based readout system for both biochemical interaction analyses as well as cellular assays was presented employing the intensity change of a near cut-off mode. As an alternative for multiparametric detection, a camera system for imaging detection has been implemented. A portable, camera-based system of size 13 cm × 4.9 cm × 3.5 cm with six detection areas on an RWG surface area of 11 mm × 7 mm has been demonstrated for the parallel detection of six protein binding kinetics. The signal-to-noise ratio of this system corresponds to a limit of detection of 168 M (24 ng/ml). To further improve the signal-to-noise ratio advanced nanostructure designs are investigated for RWGs. Here, results on multiperiodic and deterministic aperiodic nanostructures are presented. These advanced nanostructures allow for the design of the number and wavelengths of the RWG resonances. In the context of intensity-based readout systems they are particularly interesting for the realization of multi-LED systems. These recent trends suggest that compact point-of-care systems employing disposable test chips with RWG functional areas may reach market in the near future.
An OFDM System Using Polyphase Filter and DFT Architecture for Very High Data Rate Applications
NASA Technical Reports Server (NTRS)
Kifle, Muli; Andro, Monty; Vanderaar, Mark J.
2001-01-01
This paper presents a conceptual architectural design of a four-channel Orthogonal Frequency Division Multiplexing (OFDM) system with an aggregate information throughput of 622 megabits per second (Mbps). Primary emphasis is placed on the generation and detection of the composite waveform using polyphase filter and Discrete Fourier Transform (DFT) approaches to digitally stack and bandlimit the individual carriers. The four-channel approach enables the implementation of a system that can be both power and bandwidth efficient, yet enough parallelism exists to meet higher data rate goals. It also enables a DC power efficient transmitter that is suitable for on-board satellite systems, and a moderately complex receiver that is suitable for low-cost ground terminals. The major advantage of the system as compared to a single channel system is lower complexity and DC power consumption. This is because the highest sample rate is half that of the single channel system and synchronization can occur at most, depending on the synchronization technique, a quarter of the rate of a single channel system. The major disadvantage is the increased peak-to-average power ratio over the single channel system. Simulation results in a form of bit-error-rate (BER) curves are presented in this paper.
Heisenberg limit for displacements with semiclassical states
NASA Astrophysics Data System (ADS)
Luis, Alfredo
2004-04-01
We analyze the quantum limit to the sensitivity of the detection of small displacements. We focus on the case of free particles and harmonic oscillators as the systems experiencing the displacement. We show that the minimum displacement detectable is proportional to the inverse of the square root of the mean value of the energy in the state experiencing the displacement (Heisenberg limit). We present a measuring scheme that reaches this limit using semiclassical states. We examine the performance of this strategy under realistic practical conditions by computing the effect of imperfections such as losses and nonunit detection efficiencies. This analysis confirms the robustness of this measuring strategy by showing that the experimental imperfections can be suitably compensated by increasing the mean energy of the input state.
Machine learning and next-generation asteroid surveys
NASA Astrophysics Data System (ADS)
Nugent, Carrie R.; Dailey, John; Cutri, Roc M.; Masci, Frank J.; Mainzer, Amy K.
2017-10-01
Next-generation surveys such as NEOCam (Mainzer et al., 2016) will sift through tens of millions of point source detections daily to detect and discover asteroids. This requires new, more efficient techniques to distinguish between solar system objects, background stars and galaxies, and artifacts such as cosmic rays, scattered light and diffraction spikes.Supervised machine learning is a set of algorithms that allows computers to classify data on a training set, and then apply that classification to make predictions on new datasets. It has been employed by a broad range of fields, including computer vision, medical diagnoses, economics, and natural language processing. It has also been applied to astronomical datasets, including transient identification in the Palomar Transient Factory pipeline (Masci et al., 2016), and in the Pan-STARRS1 difference imaging (D. E. Wright et al., 2015).As part of the NEOCam extended phase A work we apply machine learning techniques to the problem of asteroid detection. Asteroid detection is an ideal application of supervised learning, as there is a wealth of metrics associated with each extracted source, and suitable training sets are easily created. Using the vetted NEOWISE dataset (E. L. Wright et al., 2010, Mainzer et al., 2011) as a proof-of-concept of this technique, we applied the python package sklearn. We report on reliability, feature set selection, and the suitability of various algorithms.
Expert system constant false alarm rate processor
NASA Astrophysics Data System (ADS)
Baldygo, William J., Jr.; Wicks, Michael C.
1993-10-01
The requirements for high detection probability and low false alarm probability in modern wide area surveillance radars are rarely met due to spatial variations in clutter characteristics. Many filtering and CFAR detection algorithms have been developed to effectively deal with these variations; however, any single algorithm is likely to exhibit excessive false alarms and intolerably low detection probabilities in a dynamically changing environment. A great deal of research has led to advances in the state of the art in Artificial Intelligence (AI) and numerous areas have been identified for application to radar signal processing. The approach suggested here, discussed in a patent application submitted by the authors, is to intelligently select the filtering and CFAR detection algorithms being executed at any given time, based upon the observed characteristics of the interference environment. This approach requires sensing the environment, employing the most suitable algorithms, and applying an appropriate multiple algorithm fusion scheme or consensus algorithm to produce a global detection decision.
Barakat, Tahsin Stefan; Gribnau, Joost
2014-01-01
Fluorescent in situ hybridization (FISH) is a molecular technique which enables the detection of nucleic acids in cells. DNA FISH is often used in cytogenetics and cancer diagnostics, and can detect aberrations of the genome, which often has important clinical implications. RNA FISH can be used to detect RNA molecules in cells and has provided important insights in regulation of gene expression. Combining DNA and RNA FISH within the same cell is technically challenging, as conditions suitable for DNA FISH might be too harsh for fragile, single stranded RNA molecules. We here present an easily applicable protocol which enables the combined, simultaneous detection of Xist RNA and DNA encoded by the X chromosomes. This combined DNA-RNA FISH protocol can likely be applied to other systems where both RNA and DNA need to be detected. PMID:24961515
Demonstration of a Speckle Based Sensing with Pulse-Doppler Radar for Vibration Detection.
Ozana, Nisan; Bauer, Reuven; Ashkenazy, Koby; Sasson, Nissim; Schwarz, Ariel; Shemer, Amir; Zalevsky, Zeev
2018-05-03
In previous works, an optical technique for extraction and separation of remote static vibrations has been demonstrated. In this paper, we will describe an approach in which RF speckle movement is used to extract remote vibrations of a static target. The use of conventional radar Doppler methods is not suitable for detecting vibrations of static targets. In addition, the speckle method has an important advantage, in that it is able to detect vibrations at far greater distances than what is normally detected in classical optical methods. The experiment described in this paper was done using a motorized vehicle, which engine was turned on and off. The results showed that the system was able to distinguish between the different engine states, and in addition, was able to determine the vibration frequency of the engine. The first step towards real time detection of human vital signs using RF speckle patterns is presented.
Passive imaging based multi-cue hazard detection spacecraft safe landing
NASA Technical Reports Server (NTRS)
Huertas, Andres; Cheng, Yang; Madison, Richard
2006-01-01
Accurate assessment of potentially damaging ground hazards during the spacecraft EDL (Entry, Descent and Landing) phase is crucial to insure a high probability of safe landing. A lander that encounters a large rock, falls off a cliff, or tips over on a steep slope can sustain mission ending damage. Guided entry is expected to shrink landing ellipses from 100-300 km to -10 km radius for the second generation landers as early as 2009. Regardless of size and location, however, landing ellipses will almost always contain hazards such as craters, discontinuities, steep slopes, and large rocks. It is estimated that an MSL (Mars Science Laboratory)-sized lander should detect and avoid 16- 150m diameter craters, vertical drops similar to the edges of 16m or 3.75m diameter crater, for high and low altitude HAD (Hazard Detection and Avoidance) respectively. It should also be able to detect slopes 20' or steeper, and rocks 0.75m or taller. In this paper we will present a passive imaging based, multi-cue hazard detection and avoidance (HDA) system suitable for Martian and other lander missions. This is the first passively imaged HDA system that seamlessly integrates multiple algorithm-crater detection, slope estimation, rock detection and texture analysis, and multicues- crater morphology, rock distribution, to detect these hazards in real time.
Biosensors for plant pathogen detection.
Khater, Mohga; de la Escosura-Muñiz, Alfredo; Merkoçi, Arben
2017-07-15
Infectious plant diseases are caused by pathogenic microorganisms such as fungi, bacteria, viruses, viroids, phytoplasma and nematodes. Worldwide, plant pathogen infections are among main factors limiting crop productivity and increasing economic losses. Plant pathogen detection is important as first step to manage a plant disease in greenhouses, field conditions and at the country boarders. Current immunological techniques used to detect pathogens in plant include enzyme-linked immunosorbent assays (ELISA) and direct tissue blot immunoassays (DTBIA). DNA-based techniques such as polymerase chain reaction (PCR), real time PCR (RT-PCR) and dot blot hybridization have also been proposed for pathogen identification and detection. However these methodologies are time-consuming and require complex instruments, being not suitable for in-situ analysis. Consequently, there is strong interest for developing new biosensing systems for early detection of plant diseases with high sensitivity and specificity at the point-of-care. In this context, we revise here the recent advancement in the development of advantageous biosensing systems for plant pathogen detection based on both antibody and DNA receptors. The use of different nanomaterials such as nanochannels and metallic nanoparticles for the development of innovative and sensitive biosensing systems for the detection of pathogens (i.e. bacteria and viruses) at the point-of-care is also shown. Plastic and paper-based platforms have been used for this purpose, offering cheap and easy-to-use really integrated sensing systems for rapid on-site detection. Beside devices developed at research and development level a brief revision of commercially available kits is also included in this review. Copyright © 2016 Elsevier B.V. All rights reserved.
Distributed acoustic fibre optic sensors for condition monitoring of pipelines
NASA Astrophysics Data System (ADS)
Hussels, Maria-Teresa; Chruscicki, Sebastian; Habib, Abdelkarim; Krebber, Katerina
2016-05-01
Industrial piping systems are particularly relevant to public safety and the continuous availability of infrastructure. However, condition monitoring systems based on many discrete sensors are generally not well-suited for widespread piping systems due to considerable installation effort, while use of distributed fibre-optic sensors would reduce this effort to a minimum. Specifically distributed acoustic sensing (DAS) is employed for detection of third-party threats and leaks in oil and gas pipelines in recent years and can in principle also be applied to industrial plants. Further possible detection routes amenable by DAS that could identify damage prior to emission of medium are subject of a current project at BAM, which aims at qualifying distributed fibre optic methods such as DAS as a means for spatially continuous monitoring of industrial piping systems. Here, first tests on a short pipe are presented, where optical fibres were applied directly to the surface. An artificial signal was used to define suitable parameters of the measurement system and compare different ways of applying the sensor.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Di Sieno, Laura, E-mail: laura.disieno@polimi.it; Dalla Mora, Alberto; Contini, Davide
2016-03-15
We present a system for non-contact time-resolved diffuse reflectance imaging, based on small source-detector distance and high dynamic range measurements utilizing a fast-gated single-photon avalanche diode. The system is suitable for imaging of diffusive media without any contact with the sample and with a spatial resolution of about 1 cm at 1 cm depth. In order to objectively assess its performances, we adopted two standardized protocols developed for time-domain brain imagers. The related tests included the recording of the instrument response function of the setup and the responsivity of its detection system. Moreover, by using liquid turbid phantoms with absorbingmore » inclusions, depth-dependent contrast and contrast-to-noise ratio as well as lateral spatial resolution were measured. To illustrate the potentialities of the novel approach, the characteristics of the non-contact system are discussed and compared to those of a fiber-based brain imager.« less
An integrated fluorescence detection system in poly(dimethylsiloxane) for microfluidic applications.
Chabinyc, M L; Chiu, D T; McDonald, J C; Stroock, A D; Christian, J F; Karger, A M; Whitesides, G M
2001-09-15
This paper describes a prototype of an integrated fluorescence detection system that uses a microavalanche photodiode (microAPD) as the photodetector for microfluidic devices fabricated in poly(dimethylsiloxane) (PDMS). The prototype device consisted of a reusable detection system and a disposable microfluidic system that was fabricated using rapid prototyping. The first step of the procedure was the fabrication of microfluidic channels in PDMS and the encapsulation of a multimode optical fiber (100-microm core diameter) in the PDMS; the tip of the fiber was placed next to the side wall of one of the channels. The optical fiber was used to couple light into the microchannel for the excitation of fluorescent analytes. The photodetector, a prototype solid-state microAPD array, was embedded in a thick slab (1 cm) of PDMS. A thin (80 microm) colored polycarbonate filter was placed on the top of the embedded microAPD to absorb scattered excitation light before it reached the detector. The microAPD was placed below the microchannel and orthogonal to the axis of the optical fiber. The close proximity (approximately 200 microm) of the microAPD to the microchannel made it unnecessary to incorporate transfer optics; the pixel size of the microAPD (30 microm) matched the dimensions of the channels (50 microm). A blue light-emitting diode was used for fluorescence excitation. The microAPD was operated in Geiger mode to detect the fluorescence. The detection limit of the prototype (approximately 25 nM) was determined by finding the minimum detectable concentration of a solution of fluorescein. The device was used to detect the separation of a mixture of proteins and small molecules by capillary electrophoresis; the separation illustrated the suitability of this integrated fluorescence detection system for bioanalytical applications.
Boso, Gianluca; Ke, Damei; Korzh, Boris; Bouilloux, Jordan; Lange, Norbert; Zbinden, Hugo
2015-01-01
In clinical applications, such as PhotoDynamic Therapy, direct singlet-oxygen detection through its luminescence in the near-infrared range (1270 nm) has been a challenging task due to its low emission probability and the lack of suitable single-photon detectors. Here, we propose a practical setup based on a negative-feedback avalanche diode detector that is a viable alternative to the current state-of-the art for different clinical scenarios, especially where geometric collection efficiency is limited (e.g. fiber-based systems, confocal microscopy, scanning systems etc.). The proposed setup is characterized with Rose Bengal as a standard photosensitizer and it is used to measure the singlet-oxygen quantum yield of a new set of photosensitizers for site-selective photodynamic therapy. PMID:26819830
Analysis of methods for growth detection in the search for extraterrestrial life.
Merek, E L; Oyama, V I
1968-05-01
In the search for life on other planets, experiments designed to detect the growth of microorganisms may prove to be definitive when coupled with chemical characterization and metabolic experiments. If organisms are not abundant, growth provides the only means for obtaining a large mass of biological material suitable for chemical compositional analyses and metabolic assays. Several methods of monitoring growth are described. Of these, optical monitoring in a unique system free of soil particles is advanced as the most appropriate. Theoretical problems related to the formulation of culture media are discussed, and several possible solutions are proposed. The sampling system, the type of monitoring, the size and placement of inoculum, and the medium volume and composition are contingent upon one another and must be integrated without sacrifice to the biological demands.
Sommer, D; Enderlein, D; Antakli, A; Schönenbrücher, H; Slaghuis, J; Redmann, T; Lierz, M
2012-01-01
The efficiency of two commercial PCR methods based on real-time technology, the foodproof® Salmonella detection system and the BAX® PCR Assay Salmonella system was compared to standardized culture methods (EN ISO 6579:2002 - Annex D) for the detection of Salmonella spp. in poultry samples. Four sample matrices (feed, dust, boot swabs, feces) obtained directly from poultry flocks, as well as artificially spiked samples of the same matrices, were used. All samples were tested for Salmonella spp. using culture methods first as the gold standard. In addition samples spiked with Salmonella Enteridis were tested to evaluate the sensitivity of both PCR methods. Furthermore all methods were evaluated in an annual ring-trial of the National Salmonella Reference Laboratory of Germany. Salmonella detection in the matrices feed, dust and boot swabs were comparable in both PCR systems whereas the results from feces differed markedly. The quality, especially the freshness, of the fecal samples had an influence on the sensitivity of the real-time PCR and the results of the culture methods. In fresh fecal samples an initial spiking level of 100cfu/25g Salmonella Enteritidis was detected. Two-days-dried fecal samples allowed the detection of 14cfu/25g. Both real- time PCR protocols appear to be suitable for the detection of Salmonella spp. in all four matrices. The foodproof® system detected eight samples more to be positive compared to the BAX® system, but had a potential false positive result in one case. In 7-days-dried samples none of the methods was able to detect Salmonella likely through letal cell damage. In general the advantage of PCR analyses over the culture method is the reduction of working time from 4-5 days to only 2 days. However, especially for the analysis of fecal samples official validation should be conducted according to the requirement of EN ISO6579:2002 - Annex D.
Discovering operating modes in telemetry data from the Shuttle Reaction Control System
NASA Technical Reports Server (NTRS)
Manganaris, Stefanos; Fisher, Doug; Kulkarni, Deepak
1994-01-01
This paper addresses the problem of detecting and diagnosing faults in physical systems, for which suitable system models are not available. An architecture is proposed that integrates the on-line acquisition and exploitation of monitoring and diagnostic knowledge. The focus is on the component of the architecture that discovers classes of behaviors with similar characteristics by observing a system in operation. A characterization of behaviors based on best fitting approximation models is investigated. An experimental prototype has been implemented to test it. Preliminary results in diagnosing faults of the reaction control system of the space shuttle are presented. The merits and limitations of the approach are identified and directions for future work are set.
Meiotic aneuploidy: its origins and induction following chemical treatment in Sordaria brevicollis.
Bond, D J; McMillan, L
1979-08-01
A system suitable for the detection of meiotic aneuploidy is described in which various different origins of the aneuploidy can be distinguished. Aneuploid meiotic products are detected as black disomic spores held in asci containing all the products of a single meiosis. Aneuploidy may result from nondisjunction or from a meiosis in which an extra replica of one of the chromosomes has been generated in some other way, e.g., extra replication. By using this system it has been shown that pFPA treatment increase aneuploidy, primarily through an effect on nondisjunction. Preliminary results with trifluralin have indicated that this compound, too, may increase aneuploidy. There is a good possibility that the system can be further developed to permit a more rapid screening using a random plating method; this will allow a more efficient two-part analysis of the effects of compounds under test.
A special vegetation index for the weed detection in sensor based precision agriculture.
Langner, Hans-R; Böttger, Hartmut; Schmidt, Helmut
2006-06-01
Many technologies in precision agriculture (PA) require image analysis and image- processing with weed and background differentiations. The detection of weeds on mulched cropland is one important image-processing task for sensor based precision herbicide applications. The article introduces a special vegetation index, the Difference Index with Red Threshold (DIRT), for the weed detection on mulched croplands. Experimental investigations in weed detection on mulched areas point out that the DIRT performs better than the Normalized Difference Vegetation Index (NDVI). The result of the evaluation with four different decision criteria indicate, that the new DIRT gives the highest reliability in weed/background differentiation on mulched areas. While using the same spectral bands (infrared and red) as the NDVI, the new DIRT is more suitable for weed detection than the other vegetation indices and requires only a small amount of additional calculation power. The new vegetation index DIRT was tested on mulched areas during automatic ratings with a special weed camera system. The test results compare the new DIRT and three other decision criteria: the difference between infrared and red intensity (Diff), the soil-adjusted quotient between infrared and red intensity (Quotient) and the NDVI. The decision criteria were compared with the definition of a worse case decision quality parameter Q, suitable for mulched croplands. Although this new index DIRT needs further testing, the index seems to be a good decision criterion for the weed detection on mulched areas and should also be useful for other image processing applications in precision agriculture. The weed detection hardware and the PC program for the weed image processing were developed with funds from the German Federal Ministry of Education and Research (BMBF).
A hybrid approach for efficient anomaly detection using metaheuristic methods
Ghanem, Tamer F.; Elkilani, Wail S.; Abdul-kader, Hatem M.
2014-01-01
Network intrusion detection based on anomaly detection techniques has a significant role in protecting networks and systems against harmful activities. Different metaheuristic techniques have been used for anomaly detector generation. Yet, reported literature has not studied the use of the multi-start metaheuristic method for detector generation. This paper proposes a hybrid approach for anomaly detection in large scale datasets using detectors generated based on multi-start metaheuristic method and genetic algorithms. The proposed approach has taken some inspiration of negative selection-based detector generation. The evaluation of this approach is performed using NSL-KDD dataset which is a modified version of the widely used KDD CUP 99 dataset. The results show its effectiveness in generating a suitable number of detectors with an accuracy of 96.1% compared to other competitors of machine learning algorithms. PMID:26199752
Dynamic Metasurface Aperture as Smart Around-the-Corner Motion Detector.
Del Hougne, Philipp; F Imani, Mohammadreza; Sleasman, Timothy; Gollub, Jonah N; Fink, Mathias; Lerosey, Geoffroy; Smith, David R
2018-04-25
Detecting and analysing motion is a key feature of Smart Homes and the connected sensor vision they embrace. At present, most motion sensors operate in line-of-sight Doppler shift schemes. Here, we propose an alternative approach suitable for indoor environments, which effectively constitute disordered cavities for radio frequency (RF) waves; we exploit the fundamental sensitivity of modes of such cavities to perturbations, caused here by moving objects. We establish experimentally three key features of our proposed system: (i) ability to capture the temporal variations of motion and discern information such as periodicity ("smart"), (ii) non line-of-sight motion detection, and (iii) single-frequency operation. Moreover, we explain theoretically and demonstrate experimentally that the use of dynamic metasurface apertures can substantially enhance the performance of RF motion detection. Potential applications include accurately detecting human presence and monitoring inhabitants' vital signs.
A hybrid approach for efficient anomaly detection using metaheuristic methods.
Ghanem, Tamer F; Elkilani, Wail S; Abdul-Kader, Hatem M
2015-07-01
Network intrusion detection based on anomaly detection techniques has a significant role in protecting networks and systems against harmful activities. Different metaheuristic techniques have been used for anomaly detector generation. Yet, reported literature has not studied the use of the multi-start metaheuristic method for detector generation. This paper proposes a hybrid approach for anomaly detection in large scale datasets using detectors generated based on multi-start metaheuristic method and genetic algorithms. The proposed approach has taken some inspiration of negative selection-based detector generation. The evaluation of this approach is performed using NSL-KDD dataset which is a modified version of the widely used KDD CUP 99 dataset. The results show its effectiveness in generating a suitable number of detectors with an accuracy of 96.1% compared to other competitors of machine learning algorithms.
Wired and Wireless Camera Triggering with Arduino
NASA Astrophysics Data System (ADS)
Kauhanen, H.; Rönnholm, P.
2017-10-01
Synchronous triggering is an important task that allows simultaneous data capture from multiple cameras. Accurate synchronization enables 3D measurements of moving objects or from a moving platform. In this paper, we describe one wired and four wireless variations of Arduino-based low-cost remote trigger systems designed to provide a synchronous trigger signal for industrial cameras. Our wireless systems utilize 315 MHz or 434 MHz frequencies with noise filtering capacitors. In order to validate the synchronization accuracy, we developed a prototype of a rotating trigger detection system (named RoTriDeS). This system is suitable to detect the triggering accuracy of global shutter cameras. As a result, the wired system indicated an 8.91 μs mean triggering time difference between two cameras. Corresponding mean values for the four wireless triggering systems varied between 7.92 and 9.42 μs. Presented values include both camera-based and trigger-based desynchronization. Arduino-based triggering systems appeared to be feasible, and they have the potential to be extended to more complicated triggering systems.
Review of methodology and technology available for the detection of extrasolar planetary systems
NASA Technical Reports Server (NTRS)
Tarter, J. C.; Black, D. C.; Billingham, J.
1986-01-01
Anyone undertaking an interstellar voyage might wish to be assured of the existence of a safe planetary harbor at the other end! Aside from the obvious interest of the participants in this Symposium, astronomers and astrophysicists are also eager to detect and study other planetary systems in order to better understand the formation of our own Solar System. Scientists involved in the search for extraterrestrial intelligence argue that planets suitable for the evolution of life may abound elsewhere within our own Milky Way Galaxy. On theoretical grounds, they are probably correct, but they lack any observational support. For in spite of decades of claimed astrometric detections of planetary companions and the recent exciting and tantalizing observations from the IRAS satellite and the IR speckle observations of Van Biesbroeck 8 and other cool stars, there is no unambiguous proof for the existence of another planetary system beyond our own. In this paper we review the various methods for detecting extrasolar planets and briefly describe the Earth and space based technology currently available and discuss the near-term plans to implement these different search techniques. In each case an attempt is made to identify the limiting source of systematic error inherent to the methodology and to assess the potential for technological improvements.
Jiang, J; Ma, G M; Luo, D P; Li, C R; Li, Q M; Wang, W
2014-02-01
Damped AC voltages detection system (DAC) is a productive way to detect the faults in power cables. To solve the problems of large volume, complicated structure and electromagnetic interference in existing switches, this paper developed a compact solid state switch based on electromagnetic trigger, which is suitable for DAC test system. Synchronous electromagnetic trigger of 32 Insulated Gate Bipolar Transistors (IGBTs) in series was realized by the topological structure of single line based on pulse width modulation control technology. In this way, external extension was easily achieved. Electromagnetic trigger and resistor-capacitor-diode snubber circuit were optimized to reduce the switch turn-on time and circular layout. Epoxy encapsulating was chosen to enhance the level of partial discharge initial voltage (PDIV). The combination of synchronous trigger and power supply is proposed to reduce the switch volume. Moreover, we have overcome the drawback of the electromagnetic interference and improved the detection sensitivity of DAC by using capacitor storage energy to maintain IGBT gate driving voltage. The experimental results demonstrated that the solid-state switch, with compact size, whose turn-on time was less than 400 ns and PDIV was more than 65 kV, was able to meet the actual demands of 35 kV DAC test system.
Nonaqueous capillary electrophoresis with indirect electrochemical detection.
Matysik, Frank-Michael; Marggraf, Daniela; Gläser, Petra; Broekaert, José A C
2002-11-01
Nonaqueous capillary electrophoresis (NACE) which makes use of organic solvents in place of conventional aqueous electrophoresis buffers is gaining increasing importance among modern separation techniques. Recently, it has been shown that amperometric detection in conjunction with acetonitrile-based NACE offers an extended accessible potential range and an enhanced long-term stability of the amperometric responses generated at solid electrodes. The present contribution takes advantage of the latter aspect to develop reliable systems for NACE with indirect electrochemical detection (IED). In this context, several compounds such as (ferrocenylmethyl)trimethylammonium perchlorate, tris(1,10-phenanthroline)cobalt(III) perchlorate and bis(1,4,7-triazacyclononane)nickel(II) perchlorate were studied regarding their suitability to act as electroactive buffer additives for IED in NACE. The performance characteristics for the respective buffer systems were evaluated. Tetraalkylammonium perchlorates served as model compounds for the optimization of the NACE-IED system. Target analytes choline and acetylcholine could easily be separated and determined by means of NACE-IED. In the case of a buffer system containing 10(-4) M tris(1,10-phenanthroline)cobalt(III) perchlorate the limits of detection were 2.5 x 10(-7) M and 4.6 x 10(-7) M for choline and acetylcholine, respectively. With the elaborated analytical procedure choline could be determined in pharmaceutical preparations.
Review of methodology and technology available for the detection of extrasolar planetary systems.
Tarter, J C; Black, D C; Billingham, J
1986-01-01
Anyone undertaking an interstellar voyage might wish to be assured of the existence of a safe planetary harbor at the other end! Aside from the obvious interest of the participants in this Symposium, astronomers and astrophysicists are also eager to detect and study other planetary systems in order to better understand the formation of our own Solar System. Scientists involved in the search for extraterrestrial intelligence argue that planets suitable for the evolution of life may abound elsewhere within our own Milky Way Galaxy. On theoretical grounds, they are probably correct, but they lack any observational support. For in spite of decades of claimed astrometric detections of planetary companions and the recent exciting and tantalizing observations from the IRAS satellite and the IR speckle observations of Van Biesbroeck 8 and other cool stars, there is no unambiguous proof for the existence of another planetary system beyond our own. In this paper we review the various methods for detecting extrasolar planets and briefly describe the Earth and space based technology currently available and discuss the near-term plans to implement these different search techniques. In each case an attempt is made to identify the limiting source of systematic error inherent to the methodology and to assess the potential for technological improvements.
Negri, Lucas; Nied, Ademir; Kalinowski, Hypolito; Paterno, Aleksander
2011-01-01
This paper presents a benchmark for peak detection algorithms employed in fiber Bragg grating spectrometric interrogation systems. The accuracy, precision, and computational performance of currently used algorithms and those of a new proposed artificial neural network algorithm are compared. Centroid and gaussian fitting algorithms are shown to have the highest precision but produce systematic errors that depend on the FBG refractive index modulation profile. The proposed neural network displays relatively good precision with reduced systematic errors and improved computational performance when compared to other networks. Additionally, suitable algorithms may be chosen with the general guidelines presented. PMID:22163806
Method and apparatus for concentrating vapors for analysis
Grate, Jay W [West Richland, WA; Baldwin, David L [Kennewick, WA; Anheier, Jr., Norman C.
2012-06-05
A pre-concentration device and a method are disclosed for concentrating gaseous vapors for analysis. Vapors sorbed and concentrated within the bed of the pre-concentration device are thermally desorbed, achieving at least partial separation of the vapor mixtures. The pre-concentration device is suitable, e.g., for pre-concentration and sample injection, and provides greater resolution of peaks for vapors within vapor mixtures, yielding detection levels that are 10-10,000 times better than direct sampling and analysis systems. Features are particularly useful for continuous unattended monitoring applications. The invention finds application in conjunction with, e.g., analytical instruments where low detection limits for gaseous vapors are desirable.
NASA Astrophysics Data System (ADS)
DeLuna, Frank; Ding, XiaoFie; Sun, Lu-Zhe; Ye, Jing Yong
2017-02-01
Biomarker screening for prostate-specific antigen (PSA) is the current clinical standard for detection of prostate cancer. However this method has shown many limitations, mainly in its specificity, which can lead to a high false positive rate. Thus, there is a growing need in developing a more specific detection system for prostate cancer. Using a Photonic- Crystal-based biosensor in a Total-Internal-Reflection (PC-TIR) configuration, we demonstrate the use of refractive index (RI) to accomplish label-free detection of prostate cancer cells against non-cancerous prostate epithelial cells. The PC-TIR biosensor possesses an open microcavity, which in contrast to traditional closed microcavities, allows for easier access of analyte molecules or cells to interact with its sensing surface. In this study, an imaging system was designed using the PC-TIR biosensor to quantify cell RI as the contrast parameter for prostate cancer detection. Non-cancerous BPH-1 prostate epithelial cells and prostate cancer PC-3 cells were placed on a single biosensor and measured concurrently. Recorded image data was then analyzed through a home-built MatLab program. Results demonstrate that RI is a suitable variable for differentiation between prostate cancer cells and non-cancerous prostate epithelial cells. Our study shows clinical potential in utilizing RI test for the detection of prostate cancer.
Baoutina, A; Coldham, T; Bains, G S; Emslie, K R
2010-08-01
As clinical gene therapy has progressed toward realizing its potential, concern over misuse of the technology to enhance performance in athletes is growing. Although 'gene doping' is banned by the World Anti-Doping Agency, its detection remains a major challenge. In this study, we developed a methodology for direct detection of the transferred genetic material and evaluated its feasibility for gene doping detection in blood samples from athletes. Using erythropoietin (EPO) as a model gene and a simple in vitro system, we developed real-time PCR assays that target sequences within the transgene complementary DNA corresponding to exon/exon junctions. As these junctions are absent in the endogenous gene due to their interruption by introns, the approach allows detection of trace amounts of a transgene in a large background of the endogenous gene. Two developed assays and one commercial gene expression assay for EPO were validated. On the basis of ability of these assays to selectively amplify transgenic DNA and analysis of literature on testing of gene transfer in preclinical and clinical gene therapy, it is concluded that the developed approach would potentially be suitable to detect gene doping through gene transfer by analysis of small volumes of blood using regular out-of-competition testing.
NASA Astrophysics Data System (ADS)
Ngo, Hoan T.; Gandra, Naveen; Fales, Andrew M.; Taylor, Steve M.; Vo-Dinh, Tuan
2017-02-01
Nucleic acid-based molecular diagnostics at the point-of-care (POC) and in resource-limited settings is still a challenge. We present a sensitive yet simple DNA detection method with single nucleotide polymorphism (SNP) identification capability. The detection scheme involves sandwich hybridization of magnetic beads conjugated with capture probes, target sequences, and ultrabright surface-enhanced Raman Scattering (SERS) nanorattles conjugated with reporter probes. Upon hybridization, the sandwich probes are concentrated at the detection focus controlled by a magnetic system for SERS measurements. The ultrabright SERS nanorattles, consisting of a core and a shell with resonance Raman reporters loaded in the gap space between the core and the shell, serve as SERS tags for ultrasensitive signal detection. Specific DNA sequences of the malaria parasite Plasmodium falciparum and dengue virus 1 (DENV1) were used as the model marker system. Detection limit of approximately 100 attomoles was achieved. Single nucleotide polymorphism (SNP) discrimination of wild type malaria DNA and mutant malaria DNA, which confers resistance to artemisinin drugs, was also demonstrated. The results demonstrate the molecular diagnostic potential of the nanorattle-based method to both detect and genotype infectious pathogens. The method's simplicity makes it a suitable candidate for molecular diagnosis at the POC and in resource-limited settings.
Design and Development of a Salbutamol Intake Detector for Low Respiratory Treatment
NASA Astrophysics Data System (ADS)
Vui Hin, Tsen; Ilyani Ramli, Nur
2017-08-01
This paper proposed a new salbutamol intake detector design using asthma spacer and gas sensor. The device enable real time monitoring of propellant level inhaled by the infant which will decrease the recovery time of the asthma attack. Microcontroller Arduino UNO is program to control the input and output of the system. MQ6 gas sensor detecting the propellant Hydrofluoroalkane from the metered dose inhaler (MDI) canister and demonstrated the level of propellant inhaled on the LCD in real time. MQ6 gas sensor suitable used to detect concentration of propellant inside the asthma spacer due to it is low sensitive to natural gas where include the carbon dioxide exhaled by the infant. Besides this, MQ6 gas sensor also highly sensitive to propane and the preview aerosol inventor mentioned propane as propellant which used for MDI to push the salbutamol out from MDI canister. Therefore, MQ6 gas sensor is suitable to detect propellant inside asthma spacer. The output voltage of MQ6 in initial state where no propellant inside asthma spacer is between 0.55V and 0.65V. Furthermore, when the MDI canister is been pressed, the concentration of propellant is increased and the output voltage of MQ6 gas sensor also increased in ranged between 1.1V and 1.2V.
Dhingra, Madhur S; Artois, Jean; Robinson, Timothy P; Linard, Catherine; Chaiban, Celia; Xenarios, Ioannis; Engler, Robin; Liechti, Robin; Kuznetsov, Dmitri; Xiao, Xiangming; Dobschuetz, Sophie Von; Claes, Filip; Newman, Scott H; Dauphin, Gwenaëlle; Gilbert, Marius
2016-01-01
Global disease suitability models are essential tools to inform surveillance systems and enable early detection. We present the first global suitability model of highly pathogenic avian influenza (HPAI) H5N1 and demonstrate that reliable predictions can be obtained at global scale. Best predictions are obtained using spatial predictor variables describing host distributions, rather than land use or eco-climatic spatial predictor variables, with a strong association with domestic duck and extensively raised chicken densities. Our results also support a more systematic use of spatial cross-validation in large-scale disease suitability modelling compared to standard random cross-validation that can lead to unreliable measure of extrapolation accuracy. A global suitability model of the H5 clade 2.3.4.4 viruses, a group of viruses that recently spread extensively in Asia and the US, shows in comparison a lower spatial extrapolation capacity than the HPAI H5N1 models, with a stronger association with intensively raised chicken densities and anthropogenic factors. DOI: http://dx.doi.org/10.7554/eLife.19571.001 PMID:27885988
Dark field imaging system for size characterization of magnetic micromarkers
NASA Astrophysics Data System (ADS)
Malec, A.; Haiden, C.; Kokkinis, G.; Keplinger, F.; Giouroudi, I.
2017-05-01
In this paper we demonstrate a dark field video imaging system for the detection and size characterization of individual magnetic micromarkers suspended in liquid and the detection of pathogens utilizing magnetically labelled E.coli. The system follows dynamic processes and interactions of moving micro/nano objects close to or below the optical resolution limit, and is especially suitable for small sample volumes ( 10 μl). The developed detection method can be used to obtain clinical information about liquid contents when an additional biological protocol is provided, i.e., binding of microorganisms (e.g. E.coli) to specific magnetic markers. Some of the major advantages of our method are the increased sizing precision in the micro- and nano-range as well as the setup's simplicity making it a perfect candidate for miniaturized devices. Measurements can thus be carried out in a quick, inexpensive, and compact manner. A minor limitation is that the concentration range of micromarkers in a liquid sample needs to be adjusted in such a manner that the number of individual particles in the microscope's field of view is sufficient.
DOE Office of Scientific and Technical Information (OSTI.GOV)
DaSilva, L.; Marion, J.; Chase, C.
BioLuminate, Inc. planned to develop, produce and market a revolutionary diagnostic device for early breast cancer diagnosis. The device was originally invented by NASA; and exclusively licensed to BioLuminate for commercialization. At the time of the CRADA, eighty-five percent (85%) of all biopsies in the United States were found negative each year. The number of biopsies cost the health care system $23 billio n annually. A multi-sensor probe would allow surgeons to improve breast cancer scre ening and significantly reduce the number of biopsies. BioLuminate was developing an in-vivo system for the detection of cancer using a multi-sensor needle/probe. Themore » first system would be developed for the detection of breast cancer. LLNL, in collaboration with BioLuminate worked toward a detailed concept specification for the prototype multi-sensor needle/probe suitable for breast cancer analysis. BioLuminate in collaboration with LLNL, worked to develop a new version of the needle probe that would be the same size as needles commonly used to draw blood.« less
Li, Fengmei; Wei, Yaoguang; Chen, Yingyi; Li, Daoliang; Zhang, Xu
2015-12-09
Dissolved oxygen (DO) is a key factor that influences the healthy growth of fishes in aquaculture. The DO content changes with the aquatic environment and should therefore be monitored online. However, traditional measurement methods, such as iodometry and other chemical analysis methods, are not suitable for online monitoring. The Clark method is not stable enough for extended periods of monitoring. To solve these problems, this paper proposes an intelligent DO measurement method based on the fluorescence quenching mechanism. The measurement system is composed of fluorescent quenching detection, signal conditioning, intelligent processing, and power supply modules. The optical probe adopts the fluorescent quenching mechanism to detect the DO content and solves the problem, whereas traditional chemical methods are easily influenced by the environment. The optical probe contains a thermistor and dual excitation sources to isolate visible parasitic light and execute a compensation strategy. The intelligent processing module adopts the IEEE 1451.2 standard and realizes intelligent compensation. Experimental results show that the optical measurement method is stable, accurate, and suitable for online DO monitoring in aquaculture applications.
Li, Fengmei; Wei, Yaoguang; Chen, Yingyi; Li, Daoliang; Zhang, Xu
2015-01-01
Dissolved oxygen (DO) is a key factor that influences the healthy growth of fishes in aquaculture. The DO content changes with the aquatic environment and should therefore be monitored online. However, traditional measurement methods, such as iodometry and other chemical analysis methods, are not suitable for online monitoring. The Clark method is not stable enough for extended periods of monitoring. To solve these problems, this paper proposes an intelligent DO measurement method based on the fluorescence quenching mechanism. The measurement system is composed of fluorescent quenching detection, signal conditioning, intelligent processing, and power supply modules. The optical probe adopts the fluorescent quenching mechanism to detect the DO content and solves the problem, whereas traditional chemical methods are easily influenced by the environment. The optical probe contains a thermistor and dual excitation sources to isolate visible parasitic light and execute a compensation strategy. The intelligent processing module adopts the IEEE 1451.2 standard and realizes intelligent compensation. Experimental results show that the optical measurement method is stable, accurate, and suitable for online DO monitoring in aquaculture applications. PMID:26690176
Multispectral imaging system based on laser-induced fluorescence for security applications
NASA Astrophysics Data System (ADS)
Caneve, L.; Colao, F.; Del Franco, M.; Palucci, A.; Pistilli, M.; Spizzichino, V.
2016-10-01
The development of portable sensors for fast screening of crime scenes is required to reduce the number of evidences useful to be collected, optimizing time and resources. Laser based spectroscopic techniques are good candidates to this scope due to their capability to operate in field, in remote and rapid way. In this work, the prototype of a multispectral imaging LIF (Laser Induced Fluorescence) system able to detect evidence of different materials on large very crowded and confusing areas at distances up to some tens of meters will be presented. Data collected as both 2D fluorescence images and LIF spectra are suitable to the identification and the localization of the materials of interest. A reduced scan time, preserving at the same time the accuracy of the results, has been taken into account as a main requirement in the system design. An excimer laser with high energy and repetition rate coupled to a gated high sensitivity ICCD assures very good performances for this purpose. Effort has been devoted to speed up the data processing. The system has been tested in outdoor and indoor real scenarios and some results will be reported. Evidence of the plastics polypropylene (PP) and polyethilene (PE) and polyester have been identified and their localization on the examined scenes has been highlighted through the data processing. By suitable emission bands, the instrument can be used for the rapid detection of other material classes (i.e. textiles, woods, varnishes). The activities of this work have been supported by the EU-FP7 FORLAB project (Forensic Laboratory for in-situ evidence analysis in a post blast scenario).
NASA Astrophysics Data System (ADS)
Chiodini, G.; Vilardo, G.; Augusti, V.; Granieri, D.; Caliro, S.; Minopoli, C.; Terranova, C.
2007-12-01
A permanent automatic infrared (IR) station was installed at Solfatara crater, the most active zone of Campi Flegrei caldera. After a positive in situ calibration of the IR camera, we analyze 2175 thermal IR images of the same scene from 2004 to 2007. The scene includes a portion of the steam heated hot soils of Solfatara. The experiment was initiated to detect and quantify temperature changes of the shallow thermal structure of a quiescent volcano such as Solfatara over long periods. Ambient temperature is the main parameter affecting IR temperatures, while air humidity and rain control image quality. A geometric correction of the images was necessary to remove the effects of slow movement of the camera. After a suitable correction the images give a reliable and detailed picture of the temperature changes, over the period October 2004 to January 2007, which suggests that origin of the changes were linked to anthropogenic activity, vegetation growth, and the increase of the flux of hydrothermal fluids in the area of the hottest fumaroles. Two positive temperature anomalies were registered after the occurrence of two seismic swarms which affected the hydrothermal system of Solfatara in October 2005 and October 2006. It is worth noting that these signs were detected in a system characterized by a low level of activity with respect to systems affected by real volcanic crisis where more spectacular results will be expected. Results of the experiment show that this kind of monitoring system can be a suitable tool for volcanic surveillance.
Adapting Raman Spectra from Laboratory Spectrometers to Portable Detection Libraries
DOE Office of Scientific and Technical Information (OSTI.GOV)
Weatherall, James; Barber, Jeffrey B.; Brauer, Carolyn S.
2013-02-01
Raman spectral data collected with high-resolution laboratory spectrometers are processed into a for- mat suitable for importing as a user library on a 1064nm DeltaNu rst generation, eld-deployable spectrometer prototype. The two laboratory systems used are a 1064nm Bruker spectrometer and a 785nm Kaiser spectrometer. The steps taken to compensate for device-dependent spectral resolution, wavenumber shifts between instruments, and wavenumber sensitivity variation are described.
Enhancing Ground Based Telescope Performance with Image Processing
2013-11-13
driven by the need to detect small faint objects with relatively short integration times to avoid streaking of the satellite image across multiple...the time right before the eclipse. The orbital elements of the satellite were entered into the SST’s tracking system, so that the SST could be...short integration times , thereby avoiding streaking of the satellite image across multiple CCD pixels so that the objects are suitably modeled as point
Leak and Pipe Detection Method and System
NASA Technical Reports Server (NTRS)
Youngquist, Robert C. (Inventor)
2003-01-01
A method and system for locating leaks of conductive fluids from non-conductive pipes and other structures or for locat- ing non-conductive pipes or structures having conductive fluid contained therein, employ a charge generator to apply a time varying charge to the conductive fluid, and a capaci- tive type detector that can detect the variable charge that is induced in the fluid. The capacitive detector, which prefer- ably includes a handheld housing, employs a large conduc- tive pickup plate that is used to locate the pipe or leak by scanning the plate over the ground and detecting the induced charge that is generated when the plate comes in close proximity to the pipe or leak. If a leak is encountered, the resulting signal will appear over an area larger than expected for a buried pipe, assuming the leak provides an electrically conductive path between the flow and the wet surrounding ground. The detector uses any suitable type of indicator device, such as a pair of headphones that enable an operator to hear the detected signal as a chirping sound, for example.
Studying fish near ocean energy devices using underwater video
DOE Office of Scientific and Technical Information (OSTI.GOV)
Matzner, Shari; Hull, Ryan E.; Harker-Klimes, Genevra EL
The effects of energy devices on fish populations are not well-understood, and studying the interactions of fish with tidal and instream turbines is challenging. To address this problem, we have evaluated algorithms to automatically detect fish in underwater video and propose a semi-automated method for ocean and river energy device ecological monitoring. The key contributions of this work are the demonstration of a background subtraction algorithm (ViBE) that detected 87% of human-identified fish events and is suitable for use in a real-time system to reduce data volume, and the demonstration of a statistical model to classify detections as fish ormore » not fish that achieved a correct classification rate of 85% overall and 92% for detections larger than 5 pixels. Specific recommendations for underwater video acquisition to better facilitate automated processing are given. The recommendations will help energy developers put effective monitoring systems in place, and could lead to a standard approach that simplifies the monitoring effort and advances the scientific understanding of the ecological impacts of ocean and river energy devices.« less
Chromá, Magdaléna; Hricová, Kristýna; Kolář, Milan; Sauer, Pavel; Koukalová, Dagmar
2011-11-01
A total of 78 bacterial strains with known β-lactamases were used to optimize a rapid detection system consisting of multiplex polymerase chain reaction and melting curve analysis to amplify and identify blaTEM, blaSHV, and blaCTX-M genes in a single reaction. Additionally, to evaluate the applicability of this method, 32 clinical isolates of Escherichia coli displaying an extended-spectrum β-lactamase phenotype from patients hospitalized at intensive care units were tested. Results were analyzed by the Rotor-Gene operating software and Rotor-Gene ScreenClust HRM Software. The individual melting curves differed by a temperature shift or curve shape, according to the presence of β-lactamase genes. With the use of this method and direct sequencing, blaCTX-M-15-like was identified as the most prevalent β-lactamase gene. In conclusion, this novel detection system seems to be a suitable tool for rapid detection of present β-lactamase genes and their characterization. Copyright © 2011 Elsevier Inc. All rights reserved.
Real-time pose invariant logo and pattern detection
NASA Astrophysics Data System (ADS)
Sidla, Oliver; Kottmann, Michal; Benesova, Wanda
2011-01-01
The detection of pose invariant planar patterns has many practical applications in computer vision and surveillance systems. The recognition of company logos is used in market studies to examine the visibility and frequency of logos in advertisement. Danger signs on vehicles could be detected to trigger warning systems in tunnels, or brand detection on transport vehicles can be used to count company-specific traffic. We present the results of a study on planar pattern detection which is based on keypoint detection and matching of distortion invariant 2d feature descriptors. Specifically we look at the keypoint detectors of type: i) Lowe's DoG approximation from the SURF algorithm, ii) the Harris Corner Detector, iii) the FAST Corner Detector and iv) Lepetit's keypoint detector. Our study then compares the feature descriptors SURF and compact signatures based on Random Ferns: we use 3 sets of sample images to detect and match 3 logos of different structure to find out which combinations of keypoint detector/feature descriptors work well. A real-world test tries to detect vehicles with a distinctive logo in an outdoor environment under realistic lighting and weather conditions: a camera was mounted on a suitable location for observing the entrance to a parking area so that incoming vehicles could be monitored. In this 2 hour long recording we can successfully detect a specific company logo without false positives.
Mid-IR laser ultrasonic testing for fiber reinforced plastics
NASA Astrophysics Data System (ADS)
Kusano, Masahiro; Hatano, Hideki; Oguchi, Kanae; Yamawaki, Hisashi; Watanabe, Makoto; Enoki, Manabu
2018-04-01
Ultrasonic testing is the most common method to detect defects in materials and evaluate their sizes and locations. Since piezo-electric transducers are manually handled from point to point, it takes more costs for huge products such as airplanes. Laser ultrasonic testing (LUT) is a breakthrough technique. A pulsed laser generates ultrasonic waves on a material surface due to thermoelastic effect or ablation. The ultrasonic waves can be detected by another laser with an interferometer. Thus, LUT can realize instantaneous inspection without contacting a sample. A pulse laser with around 3.2 μm wavelength (in the mid-IR range) is more suitable to generate ultrasonic waves for fiber reinforced plastics (FRPs) because the light is well absorbed by the polymeric matrix. On the other hand, such a laser is not available in the market. In order to emit the mid-IR laser pulse, we came up with the application of an optical parametric oscillator and developed an efficient wavelength conversion device by pumping a compact Nd:YAG solid-state laser. Our mid-IR LUT system is most suitable for inspection of FRPs. The signal-to-noise ratio of ultrasonic waves generated by the mid-IR laser is higher than that by the Nd:YAG laser. The purpose of the present study is to evaluate the performance of the mid-IR LUT system in reflection mode. We investigated the effects of the material properties and the laser properties on the generated ultrasonic waves. In addition, C-scan images by the system were also presented.
The performance of an online osteoporosis detection system a sensitivity and specificity analysis.
Chang, Shu Fang; Hong, Chin Ming; Yang, Rong Sen
2014-07-01
To develop an online system for the detection of osteoporosis risk and to test its accuracy. Osteoporosis is a silent killer; usually, there are no symptoms, such as pain, until bone erosion and fracture occur. The risks of osteoporosis have been underestimated and neglected; as a result, osteoporosis can be as dangerous as heart diseases and cancers that lead to a healthcare crisis. Cross-sectional study. The study participants were individuals presenting for routine health examinations at a medical centre in Taiwan from 2006-2007. Women over 30 years of age who underwent dual-energy X-ray absorptiometry scanning for measurement of bone mineral density were eligible for this study. The system for osteoporosis detection and health risk, which was developed in this study, was analysed. The findings indicated a high sensitivity of 75%, specificity of 75%, positive predictive value of 75% and negative predictive value of 75%. In addition, the online osteoporosis detective system had a higher predictive power (24·2% vs. 11%) and a similar cut-off point (33% vs. 27%) compared with the tool designed by the International Osteoporosis Foundation. The online system for detection of osteoporosis risk had excellent reliability and validity. It performed well in predicting osteoporosis and the cut-off point used for identifying the risk among women at risk of developing osteoporosis. Therefore, it is suitable for the Asian women and can help women achieve the goals of early detection and health promotion. Early detection is the only way to prevent osteoporosis. Professional nurses should apply effective technology to promote health care in community-dwelling people. © 2013 John Wiley & Sons Ltd.
Graphene based strain sensor with LCP substrate
NASA Astrophysics Data System (ADS)
Nie, M.; Yang, H. S.; Xia, Y. H.
2018-02-01
A flexible strain sensor constructed by an efficient, low-cost fabrication strategy is presented in this paper. It is assembled by adhering grid-like graphene on LCP substrate. Kinds of measurement setup have been designed to verify that the proposed flexible sensor device is suitable to be used in health monitoring system. From the experiment results, it can be proved that the sensor exhibits the following features: ultra-light, relatively good sensitivity, high reversibility, superior physical robustness, easy fabrication. With the great performance of this flexible strain sensor, it is considered to play an important role in body monitoring, structural health monitoring system, fatigue detection and healthcare systems in the near future.
Penicillinase-based enzyme-linked immunosorbent assay for the detection of plant viruses.
Sudarshana, M R; Reddy, D V
1989-10-01
A penicillinase (PNC)-based, enzyme-linked immunosorbent assay (ELISA) was standardized to detect maize mosaic virus (MMV) in sorghum leaf extracts, peanut mottle virus (PMV) in pea leaf extracts, and tomato spotted wilt virus (TSWV) in peanut leaf extracts. Rabbit Fc-specific antibodies were conjugated with PNC by a single step glutaraldehyde bridge. Among several indicators tested, bromothymol blue (BTB) was found suitable for measuring PNC activity under simulated conditions. Two reagents, starch-iodine complex (SIC) and a mixed pH indicator, containing bromocresol purple and BTB (2:1) used earlier for the PNC-based ELISA, were compared with BTB for utilization in the PNC-based ELISA. SIC gave a slightly higher virus titre than BTB or the mixed pH indicator, but it often gave nonspecific reactions. Sodium or potassium salts of penicillin-G at 0.5-1.0 mg/ml and BTB at 0.2 mg/ml were found to be suitable as substrate-indicator mixture for PNC-based ELISA. The sensitivity of the PNC system was comparable to those of the alkaline phosphatase (ALP) and horseradish peroxidase (HRP) systems in detecting MMV, PMV, and TSWV. The PNC conjugate could be used at a greater dilution than those of the ALP and HRP conjugates and the BTB substrate mixture was stable for at least 3 weeks at 4 degrees C. Penicillin is readily available in developing countries, and at a substantially lower cost than p-nitrophenyl phosphate, the commonly used substrate for ALP in the plate ELISA. Thus the PNC-based ELISA provides a less expensive means for assaying plant viruses by ELISA.
New Quality Control Algorithm Based on GNSS Sensing Data for a Bridge Health Monitoring System
Lee, Jae Kang; Lee, Jae One; Kim, Jung Ok
2016-01-01
This research introduces an improvement plan for the reliability of Global Navigation Satellite System (GNSS) positioning solutions. It should be considered the most suitable methodology in terms of the adjustment and positioning of GNSS in order to maximize the utilization of GNSS applications. Though various studies have been conducted with regards to Bridge Health Monitoring System (BHMS) based on GNSS, the outliers which depend on the signal reception environment could not be considered until now. Since these outliers may be connected to GNSS data collected from major bridge members, which can reduce the reliability of a whole monitoring system through the delivery of false information, they should be detected and eliminated in the previous adjustment stage. In this investigation, the Detection, Identification, Adaptation (DIA) technique was applied and implemented through an algorithm. Moreover, it can be directly applied to GNSS data collected from long span cable stayed bridges and most of outliers were efficiently detected and eliminated simultaneously. By these effects, the reliability of GNSS should be enormously improved. Improvement on GNSS positioning accuracy is directly linked to the safety of bridges itself, and at the same time, the reliability of monitoring systems in terms of the system operation can also be increased. PMID:27240375
Use of a Small Unmanned Aircraft System for Autonomous Fire Spotting at the Great Dismal Swamp
NASA Technical Reports Server (NTRS)
Logan, Michael J.; Glaab, Louis J.; Craig, Timothy
2016-01-01
This paper describes the results of a set of experiments and analyses conducted to evaluate the capability of small unmanned aircraft systems (sUAS) to spot nascent fires in the Great Dismal Swamp (GDS) National Wildlife Refuge. This work is the result of a partnership between the National Aeronautics and Space Administration and the US Fish and Wildlife service specifically to investigate sUAS usage for fire-spotting. The objectives of the current effort were to: 1) Determine suitability and utility of low-cost Small Unmanned Aircraft Systems (sUAS) to detect nascent fires at GDS; 2) Identify and assess the necessary National Airspace System (NAS) integration issues; and 3) Provide information to GDS and the community on system requirements and concepts-of-operation (CONOPS) for conducting fire detection/support mission in the National Airspace and (4) Identify potential applications of intelligent autonomy that would enable or benefit this high-value mission. In addition, data on the ability of various low-cost sensors to detect smoke plumes and fire hot spots was generated during the experiments as well as identifying a path towards a future practical mission utility by using sUAS in beyond visual-line-of-sight operation in the National Airspace System (NAS).
New Quality Control Algorithm Based on GNSS Sensing Data for a Bridge Health Monitoring System.
Lee, Jae Kang; Lee, Jae One; Kim, Jung Ok
2016-05-27
This research introduces an improvement plan for the reliability of Global Navigation Satellite System (GNSS) positioning solutions. It should be considered the most suitable methodology in terms of the adjustment and positioning of GNSS in order to maximize the utilization of GNSS applications. Though various studies have been conducted with regards to Bridge Health Monitoring System (BHMS) based on GNSS, the outliers which depend on the signal reception environment could not be considered until now. Since these outliers may be connected to GNSS data collected from major bridge members, which can reduce the reliability of a whole monitoring system through the delivery of false information, they should be detected and eliminated in the previous adjustment stage. In this investigation, the Detection, Identification, Adaptation (DIA) technique was applied and implemented through an algorithm. Moreover, it can be directly applied to GNSS data collected from long span cable stayed bridges and most of outliers were efficiently detected and eliminated simultaneously. By these effects, the reliability of GNSS should be enormously improved. Improvement on GNSS positioning accuracy is directly linked to the safety of bridges itself, and at the same time, the reliability of monitoring systems in terms of the system operation can also be increased.
An Electronic System for the Contactless Reading of ECG Signals.
Parente, Francesca Romana; Santonico, Marco; Zompanti, Alessandro; Benassai, Mario; Ferri, Giuseppe; D'Amico, Arnaldo; Pennazza, Giorgio
2017-10-28
The aim of this work is the development of a contactless capacitive sensory system for the detection of (Electrocardiographic) ECG-like signals. The acquisition approach is based on a capacitive coupling with the patient body performed by electrodes integrated in a front-end circuit. The proposed system is able to detect changes in the electric charge related to the heart activity. Due to the target signal weakness and to the presence of other undesired signals, suitable amplification stages and analogue filters are required. Simulated results allowed us to evaluate the effectiveness of the approach, whereas experimental measurements, recorded without contact to the skin, have validated the practical effectiveness of the proposed architecture. The system operates with a supply voltage of ±9 V with an overall power consumption of about 10 mW. The analogue output of the electronic interface is connected to an ATmega328 microcontroller implementing the A/D conversion and the data acquisition. The collected data can be displayed on any multimedia support for real-time tracking applications.
Towards Breath Gas Analysis Based on Millimeter-Wave Molecular Spectroscopy
NASA Astrophysics Data System (ADS)
Rothbart, Nick; Hübers, Heinz-Wilhelm; Schmalz, Klaus; Borngräber, Johannes; Kissinger, Dietmar
2018-03-01
Breath gas analysis is a promising non-invasive tool for medical diagnosis as there are thousands of Volatile Organic Compounds (VOCs) in human breath that can be used as health monitoring markers. Millimeter-wave/terahertz molecular spectroscopy is highly suitable for breath gas analysis due to unique fingerprint spectra of many VOCs in that frequency range. We present our recent work on sensor systems for gas spectroscopy based on integrated transmitters (TX) and receivers (RX) fabricated in IHP's 0.13 μm SiGe BiCMOS technology. For a single-band system, spectroscopic measurements and beam profiles are presented. The frequency is tuned by direct voltage-frequency tuning and by a fractional-n PLL, respectively. The spectroscopic system includes a folded gas absorption cell with gas pre-concentration abilities demonstrating the detection of a 50 ppm mixture of ethanol in ambient air corresponding to a minimum detectable concentration of 260 ppb. Finally, the design of a 3-band system covering frequencies from 225 to 273 GHz is introduced.
Klaus, Christine; Beer, Martin; Saier, Regine; Schubert, Harald; Bischoff, Sabine; Süss, Jochen
2011-01-01
Tick-borne encephalitis (TBE) in animals is not well understood yet. TBE virus (TBEV) serology in several host species could be valuable for epidemiological analyses in the field as well as for the detection of clinical cases. However, performance and suitability of the available test systems are not well assessed. Therefore, we evaluated two commercial TBEV-ELISA kits in a pilot study and compared them for their suitability in veterinary applications. For this purpose, we tested 163 field collected goat sera and evaluated the results by serum neutralization test (SNT) as "gold standard". Twenty-eight SNT positive sera (17.2%) were detected. The best suited ELISA kit was used for determination of a species-specific cutoff for horses, cattle, sheep, goats, pigs, mice, dogs, rabbits and monkeys with defined sera from animals without known or with improbable contact to TBEV. The level of non-specific ELISA results does not only differ between animal species but may also be influenced by the age of the tested animals. The number of sera which tested false positive by ELISA was higher in older than in young sheep. In order to obtain defined polyclonal sera as references, two dogs, cattle, goats, sheep, rabbits and pigs each, as well as one horse and 90 mice were immunized four times with a commercially available TBEV vaccine. In conclusion, our results demonstrated that commercial TBEV-ELISA kits are suitable for application in veterinary medicine for both, verification of clinical TBE cases and epidemiological screening. However, positive ELISA results should be verified by SNT. Only a very low number of false negative ELISA-results were found.
Suitability of Strain Gage Sensors for Integration into Smart Sport Equipment: A Golf Club Example.
Umek, Anton; Zhang, Yuan; Tomažič, Sašo; Kos, Anton
2017-04-21
Wearable devices and smart sport equipment are being increasingly used in amateur and professional sports. Smart sport equipment employs various sensors for detecting its state and actions. The correct choice of the most appropriate sensor(s) is of paramount importance for efficient and successful operation of sport equipment. When integrated into the sport equipment, ideal sensors are unobstructive, and do not change the functionality of the equipment. The article focuses on experiments for identification and selection of sensors that are suitable for the integration into a golf club with the final goal of their use in real time biofeedback applications. We tested two orthogonally affixed strain gage (SG) sensors, a 3-axis accelerometer, and a 3-axis gyroscope. The strain gage sensors are calibrated and validated in the laboratory environment by a highly accurate Qualisys Track Manager (QTM) optical tracking system. Field test results show that different types of golf swing and improper movement in early phases of golf swing can be detected with strain gage sensors attached to the shaft of the golf club. Thus they are suitable for biofeedback applications to help golfers to learn repetitive golf swings. It is suggested that the use of strain gage sensors can improve the golf swing technical error detection accuracy and that strain gage sensors alone are enough for basic golf swing analysis. Our final goal is to be able to acquire and analyze as many parameters of a smart golf club in real time during the entire duration of the swing. This would give us the ability to design mobile and cloud biofeedback applications with terminal or concurrent feedback that will enable us to speed-up motor skill learning in golf.
Suitability of Strain Gage Sensors for Integration into Smart Sport Equipment: A Golf Club Example
Umek, Anton; Zhang, Yuan; Tomažič, Sašo; Kos, Anton
2017-01-01
Wearable devices and smart sport equipment are being increasingly used in amateur and professional sports. Smart sport equipment employs various sensors for detecting its state and actions. The correct choice of the most appropriate sensor(s) is of paramount importance for efficient and successful operation of sport equipment. When integrated into the sport equipment, ideal sensors are unobstructive, and do not change the functionality of the equipment. The article focuses on experiments for identification and selection of sensors that are suitable for the integration into a golf club with the final goal of their use in real time biofeedback applications. We tested two orthogonally affixed strain gage (SG) sensors, a 3-axis accelerometer, and a 3-axis gyroscope. The strain gage sensors are calibrated and validated in the laboratory environment by a highly accurate Qualisys Track Manager (QTM) optical tracking system. Field test results show that different types of golf swing and improper movement in early phases of golf swing can be detected with strain gage sensors attached to the shaft of the golf club. Thus they are suitable for biofeedback applications to help golfers to learn repetitive golf swings. It is suggested that the use of strain gage sensors can improve the golf swing technical error detection accuracy and that strain gage sensors alone are enough for basic golf swing analysis. Our final goal is to be able to acquire and analyze as many parameters of a smart golf club in real time during the entire duration of the swing. This would give us the ability to design mobile and cloud biofeedback applications with terminal or concurrent feedback that will enable us to speed-up motor skill learning in golf. PMID:28430147
NASA Astrophysics Data System (ADS)
Bhushan, A.; Sharker, M. H.; Karimi, H. A.
2015-07-01
In this paper, we address outliers in spatiotemporal data streams obtained from sensors placed across geographically distributed locations. Outliers may appear in such sensor data due to various reasons such as instrumental error and environmental change. Real-time detection of these outliers is essential to prevent propagation of errors in subsequent analyses and results. Incremental Principal Component Analysis (IPCA) is one possible approach for detecting outliers in such type of spatiotemporal data streams. IPCA has been widely used in many real-time applications such as credit card fraud detection, pattern recognition, and image analysis. However, the suitability of applying IPCA for outlier detection in spatiotemporal data streams is unknown and needs to be investigated. To fill this research gap, this paper contributes by presenting two new IPCA-based outlier detection methods and performing a comparative analysis with the existing IPCA-based outlier detection methods to assess their suitability for spatiotemporal sensor data streams.
NASA Astrophysics Data System (ADS)
Abazov, Victor; Alexeev, Gennady; Alexeev, Maxim; Frolov, Vladimir; Golovanov, Georgy; Kutuzov, Sergey; Piskun, Alexei; Samartsev, Alexander; Tokmenin, Valeri; Verkheev, Alexander; Vertogradov, Leonid; Zhuravlev, Nikolai
2018-04-01
The
A wearable device for emotional recognition using facial expression and physiological response.
Jangho Kwon; Da-Hye Kim; Wanjoo Park; Laehyun Kim
2016-08-01
This paper introduces a glasses-typed wearable system to detect user's emotions using facial expression and physiological responses. The system is designed to acquire facial expression through a built-in camera and physiological responses such as photoplethysmogram (PPG) and electrodermal activity (EDA) in unobtrusive way. We used video clips for induced emotions to test the system suitability in the experiment. The results showed a few meaningful properties that associate emotions with facial expressions and physiological responses captured by the developed wearable device. We expect that this wearable system with a built-in camera and physiological sensors may be a good solution to monitor user's emotional state in daily life.
NASA Astrophysics Data System (ADS)
Hyer, E. J.; Schmidt, C. C.; Hoffman, J.; Giglio, L.; Peterson, D. A.
2013-12-01
Polar and geostationary satellites are used operationally for fire detection and smoke source estimation by many near-real-time operational users, including operational forecast centers around the globe. The input satellite radiance data are processed by data providers to produce Level-2 and Level -3 fire detection products, but processing these data into spatially and temporally consistent estimates of fire activity requires a substantial amount of additional processing. The most significant processing steps are correction for variable coverage of the satellite observations, and correction for conditions that affect the detection efficiency of the satellite sensors. We describe a system developed by the Naval Research Laboratory (NRL) that uses the full raster information from the entire constellation to diagnose detection opportunities, calculate corrections for factors such as angular dependence of detection efficiency, and generate global estimates of fire activity at spatial and temporal scales suitable for atmospheric modeling. By incorporating these improved fire observations, smoke emissions products, such as NRL's FLAMBE, are able to produce improved estimates of global emissions. This talk provides an overview of the system, demonstrates the achievable improvement over older methods, and describes challenges for near-real-time implementation.
Li, Xiujuan; Zeng, Zhaorui; Zeng, Yi
2007-06-15
This paper investigates the detection of 2,3-dimethyl-2,3-dinitrobutane (DMNB), a marking agent in explosives, by gas chromatography (GC) with electron capture detection using solid-phase microextraction (SPME) as a sample preparation technique. The 25,27-dihydroxy-26,28-oxy (2',7'-dioxo-3',6'-diazaoctyl) oxy-p-tert-butylcalix[4]arene/hydroxy-terminated silicone oil coated fiber was highly sensitive to trap DMNB from ammonium nitrate matrix. The analysis was performed by extracting 2g of explosives for 30s at room temperature and then immediately introducing into the heated GC injector for 1min of thermal desorption. The method showed good linearity in the range from 0.01 to 1.0mug/g. The relative standard deviations for these extractions were <8%. The calculated limit of detection for DMNB (S/N=3) was 4.43x10(-4)mug/g, which illustrates that the proposed systems are suitable for explosive detection at trace level. This is the first report of an SPME-GC system shown to extract marking agent in explosives for subsequent detection in a simple, rapid, sensitive, and inexpensive manner.
Marshall, Brenton; Warr, Coral G.
2010-01-01
Insects can detect a large range of odors with a numerically simple olfactory system that delivers high sensitivity and accurate discrimination. Therefore, insect olfactory receptors hold great promise as biosensors for detection of volatile organic chemicals in a range of applications. The array of olfactory receptor neurons of Drosophila melanogaster is rapidly becoming the best-characterized natural nose. We have investigated the suitability of Drosophila receptors as detectors for volatiles with applications in law enforcement, emergency response, and security. We first characterized responses of the majority of olfactory neuron types to a set of diagnostic odorants. Being thus able to correctly identify neurons, we then screened for responses from 38 different types of neurons to 35 agents. We identified 13 neuron types with responses to 13 agents. As individual Drosophila receptor genes have been mapped to neuron types, we can infer which genes confer responsiveness to the neurons. The responses were confirmed for one receptor by expressing it in a nonresponsive neuron. The fly olfactory system is mainly adapted to detect volatiles from fermenting fruits. However, our findings establish that volatiles associated with illicit substances, many of which are of nonnatural origin, are also detected by Drosophila receptors. PMID:20530374
[Use of new immunoglobulin isotype-specific ELISA-systems to detect Salmonella infections in pigs].
Ehlers, Joachim; Alt, Michael; Trepnau, Daniela; Lehmann, Jörg
2006-01-01
In Germany, the program for controlling salmonella infections in pigs is based on tests detecting salmonella-lipopolysaccharide (LPS) induced antibodies in meat-juice or blood. These conventional tests which are based on the technology of enzyme-linked immunosorbent assay (ELISA) detect exclusively or mainly immunoglobulin(lg)G antibodies. Meanwhile, novel ELISA systems (WCE-ELISA, 3-Isotype-Screening-ELISA) have been developed, which additionally detect the antibody classes IgM and IgA.This fact enables the registration of fresh salmonella infections (starting with day 5 p.i.) and thus, the distinction between early and older infections. The results show that animals with early salmonella infections appear significantly more often in herds with a high than with a low prevalence. With the newly developed tests this group of animals can be detected much more efficiently and precisely than with the tests used so far. Due to their clearly improved sensitivity the application of the WCE-ELISA and the 3-Isotype-Screening-ELISA in terms of the QS-Salmonella-Monitoring program can therefore significantly improve the selection of farms with potential salmonella excretors. Additionally, the WCE-ELISA can be applied very suitable for the examination of individual animals.
Rotation-invariant features for multi-oriented text detection in natural images.
Yao, Cong; Zhang, Xin; Bai, Xiang; Liu, Wenyu; Ma, Yi; Tu, Zhuowen
2013-01-01
Texts in natural scenes carry rich semantic information, which can be used to assist a wide range of applications, such as object recognition, image/video retrieval, mapping/navigation, and human computer interaction. However, most existing systems are designed to detect and recognize horizontal (or near-horizontal) texts. Due to the increasing popularity of mobile-computing devices and applications, detecting texts of varying orientations from natural images under less controlled conditions has become an important but challenging task. In this paper, we propose a new algorithm to detect texts of varying orientations. Our algorithm is based on a two-level classification scheme and two sets of features specially designed for capturing the intrinsic characteristics of texts. To better evaluate the proposed method and compare it with the competing algorithms, we generate a comprehensive dataset with various types of texts in diverse real-world scenes. We also propose a new evaluation protocol, which is more suitable for benchmarking algorithms for detecting texts in varying orientations. Experiments on benchmark datasets demonstrate that our system compares favorably with the state-of-the-art algorithms when handling horizontal texts and achieves significantly enhanced performance on variant texts in complex natural scenes.
NASA Astrophysics Data System (ADS)
Mendoza, Edgar; Prohaska, John; Kempen, Connie; Esterkin, Yan; Sun, Sunjian
2013-05-01
Acoustic emission sensing is a leading structural health monitoring technique use for the early warning detection of structural damage associated with impacts, cracks, fracture, and delaminations in advanced materials. Current AE systems based on electronic PZT transducers suffer from various limitations that prevent its wide dynamic use in practical avionics and aerospace applications where weight, size and power are critical for operation. This paper describes progress towards the development of a wireless in-flight distributed fiber optic acoustic emission monitoring system (FAESense™) suitable for the onboard-unattended detection, localization, and classification of damage in avionics and aerospace structures. Fiber optic AE sensors offer significant advantages over its counterpart electronic AE sensors by using a high-density array of micron-size AE transducers distributed and multiplex over long lengths of a standard single mode optical fiber. Immediate SHM applications are found in commercial and military aircraft, helicopters, spacecraft, wind mil turbine blades, and in next generation weapon systems, as well as in the petrochemical and aerospace industries, civil structures, power utilities, and a wide spectrum of other applications.
Degraded visual environment image/video quality metrics
NASA Astrophysics Data System (ADS)
Baumgartner, Dustin D.; Brown, Jeremy B.; Jacobs, Eddie L.; Schachter, Bruce J.
2014-06-01
A number of image quality metrics (IQMs) and video quality metrics (VQMs) have been proposed in the literature for evaluating techniques and systems for mitigating degraded visual environments. Some require both pristine and corrupted imagery. Others require patterned target boards in the scene. None of these metrics relates well to the task of landing a helicopter in conditions such as a brownout dust cloud. We have developed and used a variety of IQMs and VQMs related to the pilot's ability to detect hazards in the scene and to maintain situational awareness. Some of these metrics can be made agnostic to sensor type. Not only are the metrics suitable for evaluating algorithm and sensor variation, they are also suitable for choosing the most cost effective solution to improve operating conditions in degraded visual environments.
NASA Technical Reports Server (NTRS)
Hoge, F. E.; Swift, R. N.
1983-01-01
Airborne lidar oil spill experiments carried out to determine the practicability of the AOFSCE (absolute oil fluorescence spectral conversion efficiency) computational model are described. The results reveal that the model is suitable over a considerable range of oil film thicknesses provided the fluorescence efficiency of the oil does not approach the minimum detection sensitivity limitations of the lidar system. Separate airborne lidar experiments to demonstrate measurement of the water column Raman conversion efficiency are also conducted to ascertain the ultimate feasibility of converting such relative oil fluorescence to absolute values. Whereas the AOFSCE model is seen as highly promising, further airborne water column Raman conversion efficiency experiments with improved temporal or depth-resolved waveform calibration and software deconvolution techniques are thought necessary for a final determination of suitability.
Detection of concealed cars in complex cargo X-ray imagery using Deep Learning.
Jaccard, Nicolas; Rogers, Thomas W; Morton, Edward J; Griffin, Lewis D
2017-01-01
Non-intrusive inspection systems based on X-ray radiography techniques are routinely used at transport hubs to ensure the conformity of cargo content with the supplied shipping manifest. As trade volumes increase and regulations become more stringent, manual inspection by trained operators is less and less viable due to low throughput. Machine vision techniques can assist operators in their task by automating parts of the inspection workflow. Since cars are routinely involved in trafficking, export fraud, and tax evasion schemes, they represent an attractive target for automated detection and flagging for subsequent inspection by operators. Development and evaluation of a novel method for the automated detection of cars in complex X-ray cargo imagery. X-ray cargo images from a stream-of-commerce dataset were classified using a window-based scheme. The limited number of car images was addressed by using an oversampling scheme. Different Convolutional Neural Network (CNN) architectures were compared with well-established bag of words approaches. In addition, robustness to concealment was evaluated by projection of objects into car images. CNN approaches outperformed all other methods evaluated, achieving 100% car image classification rate for a false positive rate of 1-in-454. Cars that were partially or completely obscured by other goods, a modus operandi frequently adopted by criminals, were correctly detected. We believe that this level of performance suggests that the method is suitable for deployment in the field. It is expected that the generic object detection workflow described can be extended to other object classes given the availability of suitable training data.
Development of a real-time microchip PCR system for portable plant disease diagnosis.
Koo, Chiwan; Malapi-Wight, Martha; Kim, Hyun Soo; Cifci, Osman S; Vaughn-Diaz, Vanessa L; Ma, Bo; Kim, Sungman; Abdel-Raziq, Haron; Ong, Kevin; Jo, Young-Ki; Gross, Dennis C; Shim, Won-Bo; Han, Arum
2013-01-01
Rapid and accurate detection of plant pathogens in the field is crucial to prevent the proliferation of infected crops. Polymerase chain reaction (PCR) process is the most reliable and accepted method for plant pathogen diagnosis, however current conventional PCR machines are not portable and require additional post-processing steps to detect the amplified DNA (amplicon) of pathogens. Real-time PCR can directly quantify the amplicon during the DNA amplification without the need for post processing, thus more suitable for field operations, however still takes time and require large instruments that are costly and not portable. Microchip PCR systems have emerged in the past decade to miniaturize conventional PCR systems and to reduce operation time and cost. Real-time microchip PCR systems have also emerged, but unfortunately all reported portable real-time microchip PCR systems require various auxiliary instruments. Here we present a stand-alone real-time microchip PCR system composed of a PCR reaction chamber microchip with integrated thin-film heater, a compact fluorescence detector to detect amplified DNA, a microcontroller to control the entire thermocycling operation with data acquisition capability, and a battery. The entire system is 25 × 16 × 8 cm(3) in size and 843 g in weight. The disposable microchip requires only 8-µl sample volume and a single PCR run consumes 110 mAh of power. A DNA extraction protocol, notably without the use of liquid nitrogen, chemicals, and other large lab equipment, was developed for field operations. The developed real-time microchip PCR system and the DNA extraction protocol were used to successfully detect six different fungal and bacterial plant pathogens with 100% success rate to a detection limit of 5 ng/8 µl sample.
Development of a Real-Time Microchip PCR System for Portable Plant Disease Diagnosis
Kim, Hyun Soo; Cifci, Osman S.; Vaughn-Diaz, Vanessa L.; Ma, Bo; Kim, Sungman; Abdel-Raziq, Haron; Ong, Kevin; Jo, Young-Ki; Gross, Dennis C.; Shim, Won-Bo; Han, Arum
2013-01-01
Rapid and accurate detection of plant pathogens in the field is crucial to prevent the proliferation of infected crops. Polymerase chain reaction (PCR) process is the most reliable and accepted method for plant pathogen diagnosis, however current conventional PCR machines are not portable and require additional post-processing steps to detect the amplified DNA (amplicon) of pathogens. Real-time PCR can directly quantify the amplicon during the DNA amplification without the need for post processing, thus more suitable for field operations, however still takes time and require large instruments that are costly and not portable. Microchip PCR systems have emerged in the past decade to miniaturize conventional PCR systems and to reduce operation time and cost. Real-time microchip PCR systems have also emerged, but unfortunately all reported portable real-time microchip PCR systems require various auxiliary instruments. Here we present a stand-alone real-time microchip PCR system composed of a PCR reaction chamber microchip with integrated thin-film heater, a compact fluorescence detector to detect amplified DNA, a microcontroller to control the entire thermocycling operation with data acquisition capability, and a battery. The entire system is 25×16×8 cm3 in size and 843 g in weight. The disposable microchip requires only 8-µl sample volume and a single PCR run consumes 110 mAh of power. A DNA extraction protocol, notably without the use of liquid nitrogen, chemicals, and other large lab equipment, was developed for field operations. The developed real-time microchip PCR system and the DNA extraction protocol were used to successfully detect six different fungal and bacterial plant pathogens with 100% success rate to a detection limit of 5 ng/8 µl sample. PMID:24349341
Verfuss, Ursula K; Gillespie, Douglas; Gordon, Jonathan; Marques, Tiago A; Miller, Brianne; Plunkett, Rachael; Theriault, James A; Tollit, Dominic J; Zitterbart, Daniel P; Hubert, Philippe; Thomas, Len
2018-01-01
Loud sound emitted during offshore industrial activities can impact marine mammals. Regulations typically prescribe marine mammal monitoring before and/or during these activities to implement mitigation measures that minimise potential acoustic impacts. Using seismic surveys under low visibility conditions as a case study, we review which monitoring methods are suitable and compare their relative strengths and weaknesses. Passive acoustic monitoring has been implemented as either a complementary or alternative method to visual monitoring in low visibility conditions. Other methods such as RADAR, active sonar and thermal infrared have also been tested, but are rarely recommended by regulatory bodies. The efficiency of the monitoring method(s) will depend on the animal behaviour and environmental conditions, however, using a combination of complementary systems generally improves the overall detection performance. We recommend that the performance of monitoring systems, over a range of conditions, is explored in a modelling framework for a variety of species. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.
Two-Phase Extraction for Comprehensive Analysis of the Plant Metabolome by NMR.
Schripsema, Jan; Dagnino, Denise
2018-01-01
Metabolomics is the area of research, which strives to obtain complete metabolic fingerprints, to detect differences between them, and to provide hypothesis to explain those differences [1]. But obtaining complete metabolic fingerprints is not an easy task. Metabolite extraction is a key step during this process, and much research has been devoted to finding the best solvent mixture to extract as much metabolites as possible.Here a procedure is described for analysis of both polar and apolar metabolites using a two-phase extraction system. D 2 O and CDCl 3 are the solvents of choice, and their major advantage is that, for the identification of the compounds, standard databases can be used because D 2 O and CDCl 3 are the solvents most commonly used for pure compound NMR spectra. The procedure enables the absolute quantification of components via the addition of suitable internal standards. The extracts are also suitable for further analysis with other systems like LC-MS or GC-MS.
A logarithmic detection system suitable for a 4π array
NASA Astrophysics Data System (ADS)
Westfall, G. D.; Yurkon, J. E.; van der Plicht, J.; Koenig, Z. M.; Jacak, B. V.; Fox, R.; Crawley, G. M.; Maier, M. R.; Hasselquist, B. E.; Tickle, R. S.; Horn, D.
1985-08-01
A low pressure multiwire proportional counter, a Bragg curve counter, and an array of CaF2/plastic scintillator telescopes have been developed in a geometry suitable for close packing into a 4π detector designed to study nucleus-nucleus reactions at 100-200 MeV/nucleon. The multiwire counter is hexagonal in shape and gives X-Y position information using resistive charge division from nichrome-coated stretched polypropylene foils. The Bragg curve counter is a hexagonal pyramid with the charge taken from a Frisch gridded anode. A field shaping grid gives the Bragg curve counter a radial field. The scintillator telescopes are shaped as truncated triangular pyramids such that when stacked together they form a truncated hexagonal pyramid. The light signal of the CaF2-plastic combination is read with one phototube using a phoswich technique to separate the ΔE signal from the E signal. The entire system has been tested so far for particles with 1 <= Z <= 18 and gives good position, charge, and time resolution.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhou, Alyssa Y.; Baruch, Moshe; Ajo-Franklin, Caroline M.
Current technologies are lacking in the area of deployable, in situ monitoring of complex chemicals in environmental applications. Microorganisms metabolize various chemical compounds and can be engineered to be analyte-specific making them naturally suited for robust chemical sensing. But, current electrochemical microbial biosensors use large and expensive electrochemistry equipment not suitable for on-site, real-time environmental analysis. We demonstrate a miniaturized, autonomous bioelectronic sensing system (BESSY) suitable for deployment for instantaneous and continuous sensing applications. We developed a 2x2 cm footprint, low power, two-channel, three-electrode electrochemical potentiostat which wirelessly transmits data for on-site microbial sensing. Furthermore, we designed a new waymore » of fabricating self-contained, submersible, miniaturized reactors (m-reactors) to encapsulate the bacteria, working, and counter electrodes. We have validated the BESSY’s ability to specifically detect a chemical amongst environmental perturbations using differential current measurements. This work paves the way for in situ microbial sensing outside of a controlled laboratory environment.« less
Nonlinear Focal Modulation Microscopy.
Zhao, Guangyuan; Zheng, Cheng; Kuang, Cuifang; Zhou, Renjie; Kabir, Mohammad M; Toussaint, Kimani C; Wang, Wensheng; Xu, Liang; Li, Haifeng; Xiu, Peng; Liu, Xu
2018-05-11
We demonstrate nonlinear focal modulation microscopy (NFOMM) to achieve superresolution imaging. Traditional approaches to superresolution that utilize point scanning often rely on spatially reducing the size of the emission pattern by directly narrowing (e.g., through minimizing the detection pinhole in Airyscan, Zeiss) or indirectly peeling its outer profiles [e.g., through depleting the outer emission region in stimulated emission depletion (STED) microscopy]. We show that an alternative conceptualization that focuses on maximizing the optical system's frequency shifting ability offers advantages in further improving resolution while reducing system complexity. In NFOMM, a spatial light modulator and a suitably intense laser illumination are used to implement nonlinear focal-field modulation to achieve a transverse spatial resolution of ∼60 nm (∼λ/10). We show that NFOMM is comparable with STED microscopy and suitable for fundamental biology studies, as evidenced in imaging nuclear pore complexes, tubulin and vimentin in Vero cells. Since NFOMM is readily implemented as an add-on module to a laser-scanning microscope, we anticipate wide utility of this new imaging technique.
Nonlinear Focal Modulation Microscopy
NASA Astrophysics Data System (ADS)
Zhao, Guangyuan; Zheng, Cheng; Kuang, Cuifang; Zhou, Renjie; Kabir, Mohammad M.; Toussaint, Kimani C.; Wang, Wensheng; Xu, Liang; Li, Haifeng; Xiu, Peng; Liu, Xu
2018-05-01
We demonstrate nonlinear focal modulation microscopy (NFOMM) to achieve superresolution imaging. Traditional approaches to superresolution that utilize point scanning often rely on spatially reducing the size of the emission pattern by directly narrowing (e.g., through minimizing the detection pinhole in Airyscan, Zeiss) or indirectly peeling its outer profiles [e.g., through depleting the outer emission region in stimulated emission depletion (STED) microscopy]. We show that an alternative conceptualization that focuses on maximizing the optical system's frequency shifting ability offers advantages in further improving resolution while reducing system complexity. In NFOMM, a spatial light modulator and a suitably intense laser illumination are used to implement nonlinear focal-field modulation to achieve a transverse spatial resolution of ˜60 nm (˜λ /10 ). We show that NFOMM is comparable with STED microscopy and suitable for fundamental biology studies, as evidenced in imaging nuclear pore complexes, tubulin and vimentin in Vero cells. Since NFOMM is readily implemented as an add-on module to a laser-scanning microscope, we anticipate wide utility of this new imaging technique.
Low cost Earth attitude sensor
NASA Astrophysics Data System (ADS)
Liberati, Fabrizio; Perrotta, Giorgio; Verzegnassi, Fulvia
2017-11-01
A patent-pending, low-cost, moderate performance, Earth Attitude Sensor for LEO satellites is described in this paper. The paper deals with the system concepts, the technology adopted and the simulation results. The sensor comprises three or four narrow field of view mini telescopes pointed towards the Earth edge to detect and measure the variation of the off-nadir angle of the Earth-to-black sky transition using thermopile detectors suitably placed in the foci of the optical min telescopes. The system's innovation consists in the opto-mechanical configuration adopted that is sturdy and has no moving parts being , thus, inherently reliable. In addition, with a view to reducing production costs, the sensor does without hi-rel and is instead mainly based on COTS parts suitably chosen. Besides it is flexible and can be adapted to perform attitude measurement onboard spacecraft flying in orbits other than LEO with a minimum of modifications to the basic design. At present the sensor is under development by IMT and OptoService.
Zhou, Alyssa Y.; Baruch, Moshe; Ajo-Franklin, Caroline M.; ...
2017-09-15
Current technologies are lacking in the area of deployable, in situ monitoring of complex chemicals in environmental applications. Microorganisms metabolize various chemical compounds and can be engineered to be analyte-specific making them naturally suited for robust chemical sensing. But, current electrochemical microbial biosensors use large and expensive electrochemistry equipment not suitable for on-site, real-time environmental analysis. We demonstrate a miniaturized, autonomous bioelectronic sensing system (BESSY) suitable for deployment for instantaneous and continuous sensing applications. We developed a 2x2 cm footprint, low power, two-channel, three-electrode electrochemical potentiostat which wirelessly transmits data for on-site microbial sensing. Furthermore, we designed a new waymore » of fabricating self-contained, submersible, miniaturized reactors (m-reactors) to encapsulate the bacteria, working, and counter electrodes. We have validated the BESSY’s ability to specifically detect a chemical amongst environmental perturbations using differential current measurements. This work paves the way for in situ microbial sensing outside of a controlled laboratory environment.« less
UWB based low-cost and non-invasive practical breast cancer early detection
NASA Astrophysics Data System (ADS)
Vijayasarveswari, V.; Khatun, S.; Fakir, M. M.; Jusoh, M.; Ali, S.
2017-03-01
Breast cancer is one of the main causes of women death worldwide. Breast tumor is an early stage of cancer that locates in cells of a human breast. As there is no remedy, early detection is crucial. Towards this, Ultra-Wideband (UWB) is a prominent candidate. It is a wireless communication technology which can achieve high bandwidth with low power utilization. UWB is suitable to be used for short range communication systems including breast cancer detection since it is secure, non-invasive and human health friendly. This paper presents the low-cost and non-invasive early breast cancer detection strategy using UWB sensor (or antenna). Emphasis is given here to detect breast tumor in 2D and 3D environments. The developed system consisted of hardware and software. Hardware included UWB transceiver and a pair of home-made directional sensor/antenna. The software included feed-forward back propagation Neural Network (NN) module to detect the tumor existence, size and location along with soft interface between software and hardware. Forward scattering technique was used by placing two sensors diagonally opposite sides of a breast phantom. UWB pulses were transmitted from one side of phantom and received from other side, controlled by the software interface in PC environment. Collected received signals were then fed into the NN module for training, testing and validation. The system exhibited detection efficiency on tumor existence, location (x, y, z), and size were approximately 100%, (78.17%, 70.66%, 92.46%), 85.86% respectively. The proposed UWB based early breast cancer detection system could be more practical with low-cost, user friendly and non-harmful features. This project may help users to monitor their breast health regularly at their home.
Spoof Detection for Finger-Vein Recognition System Using NIR Camera.
Nguyen, Dat Tien; Yoon, Hyo Sik; Pham, Tuyen Danh; Park, Kang Ryoung
2017-10-01
Finger-vein recognition, a new and advanced biometrics recognition method, is attracting the attention of researchers because of its advantages such as high recognition performance and lesser likelihood of theft and inaccuracies occurring on account of skin condition defects. However, as reported by previous researchers, it is possible to attack a finger-vein recognition system by using presentation attack (fake) finger-vein images. As a result, spoof detection, named as presentation attack detection (PAD), is necessary in such recognition systems. Previous attempts to establish PAD methods primarily focused on designing feature extractors by hand (handcrafted feature extractor) based on the observations of the researchers about the difference between real (live) and presentation attack finger-vein images. Therefore, the detection performance was limited. Recently, the deep learning framework has been successfully applied in computer vision and delivered superior results compared to traditional handcrafted methods on various computer vision applications such as image-based face recognition, gender recognition and image classification. In this paper, we propose a PAD method for near-infrared (NIR) camera-based finger-vein recognition system using convolutional neural network (CNN) to enhance the detection ability of previous handcrafted methods. Using the CNN method, we can derive a more suitable feature extractor for PAD than the other handcrafted methods using a training procedure. We further process the extracted image features to enhance the presentation attack finger-vein image detection ability of the CNN method using principal component analysis method (PCA) for dimensionality reduction of feature space and support vector machine (SVM) for classification. Through extensive experimental results, we confirm that our proposed method is adequate for presentation attack finger-vein image detection and it can deliver superior detection results compared to CNN-based methods and other previous handcrafted methods.
Spoof Detection for Finger-Vein Recognition System Using NIR Camera
Nguyen, Dat Tien; Yoon, Hyo Sik; Pham, Tuyen Danh; Park, Kang Ryoung
2017-01-01
Finger-vein recognition, a new and advanced biometrics recognition method, is attracting the attention of researchers because of its advantages such as high recognition performance and lesser likelihood of theft and inaccuracies occurring on account of skin condition defects. However, as reported by previous researchers, it is possible to attack a finger-vein recognition system by using presentation attack (fake) finger-vein images. As a result, spoof detection, named as presentation attack detection (PAD), is necessary in such recognition systems. Previous attempts to establish PAD methods primarily focused on designing feature extractors by hand (handcrafted feature extractor) based on the observations of the researchers about the difference between real (live) and presentation attack finger-vein images. Therefore, the detection performance was limited. Recently, the deep learning framework has been successfully applied in computer vision and delivered superior results compared to traditional handcrafted methods on various computer vision applications such as image-based face recognition, gender recognition and image classification. In this paper, we propose a PAD method for near-infrared (NIR) camera-based finger-vein recognition system using convolutional neural network (CNN) to enhance the detection ability of previous handcrafted methods. Using the CNN method, we can derive a more suitable feature extractor for PAD than the other handcrafted methods using a training procedure. We further process the extracted image features to enhance the presentation attack finger-vein image detection ability of the CNN method using principal component analysis method (PCA) for dimensionality reduction of feature space and support vector machine (SVM) for classification. Through extensive experimental results, we confirm that our proposed method is adequate for presentation attack finger-vein image detection and it can deliver superior detection results compared to CNN-based methods and other previous handcrafted methods. PMID:28974031
Obscenity Detection Using Haar-Like Features and Gentle Adaboost Classifier
Min, Yang; Zhu, Dingju
2014-01-01
Large exposure of skin area of an image is considered obscene. This only fact may lead to many false images having skin-like objects and may not detect those images which have partially exposed skin area but have exposed erotogenic human body parts. This paper presents a novel method for detecting nipples from pornographic image contents. Nipple is considered as an erotogenic organ to identify pornographic contents from images. In this research Gentle Adaboost (GAB) haar-cascade classifier and haar-like features used for ensuring detection accuracy. Skin filter prior to detection made the system more robust. The experiment showed that, considering accuracy, haar-cascade classifier performs well, but in order to satisfy detection time, train-cascade classifier is suitable. To validate the results, we used 1198 positive samples containing nipple objects and 1995 negative images. The detection rates for haar-cascade and train-cascade classifiers are 0.9875 and 0.8429, respectively. The detection time for haar-cascade is 0.162 seconds and is 0.127 seconds for train-cascade classifier. PMID:25003153
Portable concealed weapon detection using millimeter-wave FMCW radar imaging
NASA Astrophysics Data System (ADS)
Johnson, Michael A.; Chang, Yu-Wen
2001-02-01
Unobtrusive detection of concealed weapons on persons or in abandoned bags would provide law enforcement a powerful tool to focus resources and increase traffic throughput in high- risk situations. We have developed a fast image scanning 94 GHz radar system that is suitable for portable operation and remote viewing of radar data. This system includes a novel fast image-scanning antenna that allows for the acquisition of medium resolution 3D millimeter wave images of stationary targets with frame times on order of one second. The 3D radar data allows for potential isolation of concealed weapons from body and environmental clutter such as nearby furniture or other people. The radar is an active system so image quality is not affected indoors, emitted power is however very low so there are no health concerns for operator or targets. The low power operation is still sufficient to penetrate heavy clothing or material. Small system size allows for easy transport and rapid deployment of the system as well as an easy migration path to future hand held systems.
Fu, Wei; Wei, Shuang; Wang, Chenguang; Du, Zhixin; Zhu, Pengyu; Wu, Xiyang; Wu, Gang; Zhu, Shuifang
2017-08-15
High throughput screening systems are the preferred solution to meet the urgent requirement of increasing number of genetically modified organisms (GMOs). In this study, we have successfully developed a multiplex GMO element screening system with dual priming oligonucleotide (DPO) primers. This system can detect the cauliflower mosaic virus 35S (CaMV 35S), terminator of nopaline synthase gene (NOS), figwort mosaic virus 35S (FMV 35S) promoter, neomycin phosphotransferaseII (NPTII), Bt Cry 1Ab, phosphinothricin acetyltransferase genes (bar) and Streptomyces viridochromogenes (pat) simultaneously, which covers more than 90% of all authorized GMO species worldwide. This system exhibits a high tolerance to annealing temperatures, high specificity and a limit of detection equal to conventional PCR. A total of 214 samples from markets, national entry-exit agencies, the Institute for Reference Materials and Measurement (IRMM) and the American Oil Chemists' Society (AOCS) were also tested for applicability. This screening system is therefore suitable for GMO screening. Copyright © 2017 Elsevier Ltd. All rights reserved.
Auto-locking waveguide amplifier system for lidar and magnetometric applications
NASA Astrophysics Data System (ADS)
Pouliot, A.; Beica, H. C.; Carew, A.; Vorozcovs, A.; Carlse, G.; Kumarakrishnan, A.
2018-02-01
We describe a compact waveguide amplifier system that is suitable for optically pumping rubidium magnetometers. The system consists of an auto-locking vacuum-sealed external cavity diode laser, a semiconductor tapered amplifier and a pulsing unit based on an acousto-optic modulator. The diode laser utilises optical feedback from an interference filter to narrow the linewidth of an inexpensive laser diode to 500 kHz. This output is scannable over an 8 GHz range (at 780 nm) and can be locked without human intervention to any spectral marker in an expandable library of reference spectra, using the autolocking controller. The tapered amplifier amplifies the output from 50 mW up to 2 W with negligible distortions in the spectral quality. The system can operate at visible and near infrared wavelengths with MHz repetition rates. We demonstrate optical pumping of rubidium vapour with this system for magnetometric applications. The magnetometer detects the differential absorption of two orthogonally polarized components of a linearly polarized probe laser following optical pumping by a circularly polarized pump laser. The differential absorption signal is studied for a range of pulse lengths, pulse amplitudes and DC magnetic fields. Our results suggest that this laser system is suitable for optically pumping spin-exchange free magnetometers.
Rapid carrier screening using short tandem repeats in the phenylalanine hydroxylase gene.
Shawky, R M; el-Aleem, K A; Rifaat, M M; el-Naggar, R L; Marzouk, G M
2002-01-01
Phenylketonuria (PKU) is an autosomal recessive genetic disorder caused by defects in the phenylalanine hydroxylase (PAH) system. Our work aimed to screen the PAH locus for the presence of potentially useful short tandem repeats (STR) as markers for carrier detection in PKU families in Egypt, and to determine the level of PAH heterozygosity within the Egyptian population. The system contains at least eight independent alleles in the Egyptian population, transmitted in a Mendelian fashion. Variations in the number of STR in the 16 families studied gave rise to polymorphisms that proved to be suitable markers for PKU carrier detection and prenatal diagnosis. The most frequent allelic fragment size in PKU patients was 246 bp (35.7%), which together with a fragment of 254 bp accounted for 60.7% of the mutant chromosomes.
Applying LED in full-field optical coherence tomography for gastrointestinal endoscopy
NASA Astrophysics Data System (ADS)
Yang, Bor-Wen; Wang, Yu-Yen; Juan, Yu-Shan; Hsu, Sheng-Jie
2015-08-01
Optical coherence tomography (OCT) has become an important medical imaging technology due to its non-invasiveness and high resolution. Full-field optical coherence tomography (FF-OCT) is a scanning scheme especially suitable for en face imaging as it employs a CMOS/CCD device for parallel pixels processing. FF-OCT can also be applied to high-speed endoscopic imaging. Applying cylindrical scanning and a right-angle prism, we successfully obtained a 360° tomography of the inner wall of an intestinal cavity through an FF-OCT system with an LED source. The 10-μm scale resolution enables the early detection of gastrointestinal lesions, which can increase detection rates for esophageal, stomach, or vaginal cancer. All devices used in this system can be integrated by MOEMS technology to contribute to the studies of gastrointestinal medicine and advanced endoscopy technology.
Development of paper-gate transistor toward direct detection from microbiological fluids
NASA Astrophysics Data System (ADS)
Kajisa, Taira; Sakata, Toshiya
2017-04-01
In this study, a paper-gate transistor was developed to detect glucose using an extended-gate field-effect transistor (FET). A filter paper was used as an extended gate electrode, in which Au nanoparticles (AuNPs) modified with phenylboronic acids (PBAs) were included. PBA-AuNPs play an important role as a support to not only be entrapped in cellulose fibrils but also bind to the targeted glucose in a paper. The surface properties of PBA-AuNPs were investigated to elucidate the electrical properties of the paper-gate electrode using an absorption spectrum and a zeta potential analysis. Moreover, the paper-gate electrode enabled us to detect glucose at the micromolar level on the basis of the principle of FET devices. A platform based on the paper-gate transistor is suitable for a highly sensitive system to detect glucose in trace samples such as tears, sweat, and saliva in the future.
ECG signal analysis through hidden Markov models.
Andreão, Rodrigo V; Dorizzi, Bernadette; Boudy, Jérôme
2006-08-01
This paper presents an original hidden Markov model (HMM) approach for online beat segmentation and classification of electrocardiograms. The HMM framework has been visited because of its ability of beat detection, segmentation and classification, highly suitable to the electrocardiogram (ECG) problem. Our approach addresses a large panel of topics some of them never studied before in other HMM related works: waveforms modeling, multichannel beat segmentation and classification, and unsupervised adaptation to the patient's ECG. The performance was evaluated on the two-channel QT database in terms of waveform segmentation precision, beat detection and classification. Our waveform segmentation results compare favorably to other systems in the literature. We also obtained high beat detection performance with sensitivity of 99.79% and a positive predictivity of 99.96%, using a test set of 59 recordings. Moreover, premature ventricular contraction beats were detected using an original classification strategy. The results obtained validate our approach for real world application.
Khaled, W; Ermert, H; Bruhns, O; Boese, H; Baumann, M; Monkman, G J; Egersdoerfer, S; Meier, A; Klein, D; Freimuth, H
2003-01-01
Mechanical properties of biological tissue represent important diagnostic information and are of histological relevance (hard lesions, "nodes" in organs: tumors; calcifications in vessels: arteriosclerosis). The problem is, that such information is usually obtained by digital palpation only, which is limited with respect to sensitivity. It requires intuitive assessment and does not allow quantitative documentation. A suitable sensor is required for quantitative detection of mechanical tissue properties. On the other hand, there is also some need for a realistic mechanical display of those tissue properties. Suitable actuator arrays with high spatial resolution and real-time capabilities are required operating in a haptic sensor actuator system with different applications. The sensor system uses real time ultrasonic elastography whereas the tactile actuator is based on electrorheological fluids. Due to their small size the actuator array elements have to be manufactured by micro-mechanical production methods. In order to supply the actuator elements with individual high voltages a sophisticated switching and control concept have been designed. This haptic system has the potential of inducing real time substantial forces, using a compact lightweight mechanism which can be applied to numerous areas including intraoperative navigation, telemedicine, teaching, space and telecommunication.
Modeling and design of a cone-beam CT head scanner using task-based imaging performance optimization
NASA Astrophysics Data System (ADS)
Xu, J.; Sisniega, A.; Zbijewski, W.; Dang, H.; Stayman, J. W.; Wang, X.; Foos, D. H.; Aygun, N.; Koliatsos, V. E.; Siewerdsen, J. H.
2016-04-01
Detection of acute intracranial hemorrhage (ICH) is important for diagnosis and treatment of traumatic brain injury, stroke, postoperative bleeding, and other head and neck injuries. This paper details the design and development of a cone-beam CT (CBCT) system developed specifically for the detection of low-contrast ICH in a form suitable for application at the point of care. Recognizing such a low-contrast imaging task to be a major challenge in CBCT, the system design began with a rigorous analysis of task-based detectability including critical aspects of system geometry, hardware configuration, and artifact correction. The imaging performance model described the three-dimensional (3D) noise-equivalent quanta using a cascaded systems model that included the effects of scatter, scatter correction, hardware considerations of complementary metal-oxide semiconductor (CMOS) and flat-panel detectors (FPDs), and digitization bit depth. The performance was analyzed with respect to a low-contrast (40-80 HU), medium-frequency task representing acute ICH detection. The task-based detectability index was computed using a non-prewhitening observer model. The optimization was performed with respect to four major design considerations: (1) system geometry (including source-to-detector distance (SDD) and source-to-axis distance (SAD)); (2) factors related to the x-ray source (including focal spot size, kVp, dose, and tube power); (3) scatter correction and selection of an antiscatter grid; and (4) x-ray detector configuration (including pixel size, additive electronics noise, field of view (FOV), and frame rate, including both CMOS and a-Si:H FPDs). Optimal design choices were also considered with respect to practical constraints and available hardware components. The model was verified in comparison to measurements on a CBCT imaging bench as a function of the numerous design parameters mentioned above. An extended geometry (SAD = 750 mm, SDD = 1100 mm) was found to be advantageous in terms of patient dose (20 mGy) and scatter reduction, while a more isocentric configuration (SAD = 550 mm, SDD = 1000 mm) was found to give a more compact and mechanically favorable configuration with minor tradeoff in detectability. An x-ray source with a 0.6 mm focal spot size provided the best compromise between spatial resolution requirements and x-ray tube power. Use of a modest anti-scatter grid (8:1 GR) at a 20 mGy dose provided slight improvement (~5-10%) in the detectability index, but the benefit was lost at reduced dose. The potential advantages of CMOS detectors over FPDs were quantified, showing that both detectors provided sufficient spatial resolution for ICH detection, while the former provided a potentially superior low-dose performance, and the latter provided the requisite FOV for volumetric imaging in a centered-detector geometry. Task-based imaging performance modeling provides an important starting point for CBCT system design, especially for the challenging task of ICH detection, which is somewhat beyond the capabilities of existing CBCT platforms. The model identifies important tradeoffs in system geometry and hardware configuration, and it supports the development of a dedicated CBCT system for point-of-care application. A prototype suitable for clinical studies is in development based on this analysis.
A True-Color Sensor and Suitable Evaluation Algorithm for Plant Recognition
Schmittmann, Oliver; Schulze Lammers, Peter
2017-01-01
Plant-specific herbicide application requires sensor systems for plant recognition and differentiation. A literature review reveals a lack of sensor systems capable of recognizing small weeds in early stages of development (in the two- or four-leaf stage) and crop plants, of making spraying decisions in real time and, in addition, are that are inexpensive and ready for practical use in sprayers. The system described in this work is based on free cascadable and programmable true-color sensors for real-time recognition and identification of individual weed and crop plants. The application of this type of sensor is suitable for municipal areas and farmland with and without crops to perform the site-specific application of herbicides. Initially, databases with reflection properties of plants, natural and artificial backgrounds were created. Crop and weed plants should be recognized by the use of mathematical algorithms and decision models based on these data. They include the characteristic color spectrum, as well as the reflectance characteristics of unvegetated areas and areas with organic material. The CIE-Lab color-space was chosen for color matching because it contains information not only about coloration (a- and b-channel), but also about luminance (L-channel), thus increasing accuracy. Four different decision making algorithms based on different parameters are explained: (i) color similarity (ΔE); (ii) color similarity split in ΔL, Δa and Δb; (iii) a virtual channel ‘d’ and (iv) statistical distribution of the differences of reflection backgrounds and plants. Afterwards, the detection success of the recognition system is described. Furthermore, the minimum weed/plant coverage of the measuring spot was calculated by a mathematical model. Plants with a size of 1–5% of the spot can be recognized, and weeds in the two-leaf stage can be identified with a measuring spot size of 5 cm. By choosing a decision model previously, the detection quality can be increased. Depending on the characteristics of the background, different models are suitable. Finally, the results of field trials on municipal areas (with models of plants), winter wheat fields (with artificial plants) and grassland (with dock) are shown. In each experimental variant, objects and weeds could be recognized. PMID:28786922
A True-Color Sensor and Suitable Evaluation Algorithm for Plant Recognition.
Schmittmann, Oliver; Schulze Lammers, Peter
2017-08-08
Plant-specific herbicide application requires sensor systems for plant recognition and differentiation. A literature review reveals a lack of sensor systems capable of recognizing small weeds in early stages of development (in the two- or four-leaf stage) and crop plants, of making spraying decisions in real time and, in addition, are that are inexpensive and ready for practical use in sprayers. The system described in this work is based on free cascadable and programmable true-color sensors for real-time recognition and identification of individual weed and crop plants. The application of this type of sensor is suitable for municipal areas and farmland with and without crops to perform the site-specific application of herbicides. Initially, databases with reflection properties of plants, natural and artificial backgrounds were created. Crop and weed plants should be recognized by the use of mathematical algorithms and decision models based on these data. They include the characteristic color spectrum, as well as the reflectance characteristics of unvegetated areas and areas with organic material. The CIE-Lab color-space was chosen for color matching because it contains information not only about coloration (a- and b-channel), but also about luminance (L-channel), thus increasing accuracy. Four different decision making algorithms based on different parameters are explained: (i) color similarity (ΔE); (ii) color similarity split in ΔL, Δa and Δb; (iii) a virtual channel 'd' and (iv) statistical distribution of the differences of reflection backgrounds and plants. Afterwards, the detection success of the recognition system is described. Furthermore, the minimum weed/plant coverage of the measuring spot was calculated by a mathematical model. Plants with a size of 1-5% of the spot can be recognized, and weeds in the two-leaf stage can be identified with a measuring spot size of 5 cm. By choosing a decision model previously, the detection quality can be increased. Depending on the characteristics of the background, different models are suitable. Finally, the results of field trials on municipal areas (with models of plants), winter wheat fields (with artificial plants) and grassland (with dock) are shown. In each experimental variant, objects and weeds could be recognized.
NASA Astrophysics Data System (ADS)
Schoolderman, Arnold J.; Roosenboom, Jacques H. J.
2005-06-01
The Engineers Centre of Expertise of the Royal Netherlands Army (RNLA) has conducted a study on countermine in peace operations. This study, finished in 2002, concluded that the final solution to countermine will depend in the first place on better detection of buried low-metal mines, e.g. by direct detection of the explosive components in mines. Until such detection systems are available, intermediate solutions are necessary in order to assure freedom of movement in peace operations. Because countermine operations consist of a number of different activities (area preparation, detection, clearance, etc) and the suitability of the different types of available equipment depends on the scenario, the toolbox concept for countermine equipment was adopted. In 2003 a procurement process was started in order to fill this toolbox with commercial-off-the-shelf and military-off-the-shelf equipment. The paper gives a concise description of the study on countermine operations and the procurement process, and subsequently focuses on the set-up of the tests that were conducted in the framework of the procurement of hand-held mine detection systems, like metal detectors and dual-sensor mine detectors. Programs of requirements for these systems were drawn up, aiming at systems for general use and special purpose systems. Blind tests to check the compliancy to the detection performance requirements were designed and conducted in the short timeframe that was available in the procurement process. These tests are discussed in this paper, including the set-up of the test lanes, the targets used and their depths, and the role of the operator. The tests of the capability of the detectors to discriminate small targets adjacent to large targets were conducted according the guidelines of the CEN Workshop Agreement on metal detector tests. Although the results of the tests are commercially confidential, conclusions and lessons learned from the execution of these tests are presented.
NASA Astrophysics Data System (ADS)
Lee, Seung Yup; Pakela, Julia M.; Hedrick, Taylor L.; Vishwanath, Karthik; Helton, Michael C.; Chung, Yooree; Kolodziejski, Noah J.; Stapels, Christopher J.; McAdams, Daniel R.; Fernandez, Daniel E.; Christian, James F.; O'Reilly, Jameson; Farkas, Dana; Ward, Brent B.; Feinberg, Stephen E.; Mycek, Mary-Ann
2017-02-01
In reconstructive surgery, tissue perfusion/vessel patency is critical to the success of microvascular free tissue flaps. Early detection of flap failure secondary to compromise of vascular perfusion would significantly increase the chances of flap salvage. We have developed a compact, clinically-compatible monitoring system to enable automated, minimally-invasive, continuous, and quantitative assessment of flap viability/perfusion. We tested the system's continuous monitoring capability during extended non-recovery surgery using an in vivo porcine free flap model. Initial results indicated that the system could assess flap viability/perfusion in a quantitative and continuous manner. With proven performance, the compact form constructed with cost-effective components would make this system suitable for clinical translation.
Evaluation of appropriate sensor specifications for space based ballistic missile detection
NASA Astrophysics Data System (ADS)
Schweitzer, Caroline; Stein, Karin; Wendelstein, Norbert
2012-10-01
The detection and tracking of ballistic missiles (BMs) during launch or cloud break using satellite based electro-optical (EO) sensors is a promising possibility for pre-instructing early warning and fire control radars. However, the successful detection of a BM is depending on the applied infrared (IR)-channel, as emission and reflection of threat and background vary in different spectral (IR-) bands and for different observation scenarios. In addition, the spatial resolution of the satellite based system also conditions the signal-to-clutter-ratio (SCR) and therefore the predictability of the flight path. Generally available satellite images provide data in spectral bands, which are suitable for remote sensing applications and earth surface observations. However, in the fields of BM early warning, these bands are not of interest making the simulation of background data essential. The paper focuses on the analysis of IR-bands suitable for missile detection by trading off the suppression of background signature against threat signal strength. This comprises a radiometric overview of the background radiation in different spectral bands for different climates and seasons as well as for various cloud types and covers. A brief investigation of the BM signature and its trajectory within a threat scenario is presented. Moreover, the influence on the SCR caused by different observation scenarios and varying spatial resolution are pointed out. The paper also introduces the software used for simulating natural background spectral radiance images, MATISSE ("Advanced Modeling of the Earth for Environment and Scenes Simulation") by ONERA [1].
Development of an Electronic Kit for detecting asthma in Human Respiratory System
NASA Astrophysics Data System (ADS)
Shek Hong, Cheow; Ghani, Ahmad Shahrizan Abdul; Khairuddin, Ismail Mohd
2018-03-01
In this paper, a prototype of a carbon dioxide (CO2) measurement device is designed to detect and used to monitor asthma patients. Nowadays, capnogram device is widely used in monitoring asthma and asthma related medical services. However, capnogram is very costly and unaffordable for patient especially those who are in low income household. Thus, the proposed device is cost effective, affordable, and produced to detect and monitor the severity of asthma. Meanwhile, flow meter will cause patient to have chest pain as they needed maximum effort to blow in the device. To overcome these limitations, this prototype electronic kit is easy to use and suitable for all range patients. This prototype electronic kit consists of MH-Z14A carbon dioxide (CO2) sensor to detect the concentration of carbon dioxide from the user exhaled air. Arduino microcontroller is used to process the data while TFT Display shield is applied for data presentation. In addition, HC-06 Bluetooth module is used to communicate with PC for further analysis of the captured graph. This device was tested with 3 asthmatics and 3 normal users. The results showed that asthmatic user has a different graph pattern compared with normal user and these graphs are clearly differentiated on the device TFT screen. Asthmatic user produces “shark fin”-like pattern whereas normal user produces “square wave”-like pattern. This device has successfully produced distinguished-patterns difference between asthmatic and normal user; therefore, it is suitable for asthma monitoring.
Design of the NDUV detection circuit for the NO concentration of the vehicle exhaust emissions
NASA Astrophysics Data System (ADS)
Zhang, Kai; Zhang, Yujun; He, Ying; You, Kun; Gao, Yanwei; Chen, Chen; Liu, Guohua; He, Chungui; Lu, Yibing; Liu, Wenqing
2016-10-01
With the increasing number of vehicles, the harm from NO to the environment becomes more and more prominent. So the monitoring of the NO concentration of the vehicle exhaust emissions is very important to assess the emission levels. In this paper, the NO detection system designing for vehicle exhaust emissions based on the non-dispersive ultraviolet principle (NDUV) has been researched. The technical indexes of the two-way modulation UV signal detection circuit are discussed in detail. And then a precision detection circuit is designed, which is composed of a trans-impedance amplifier and a lock-in amplifier, with which the output of the UV photoelectric detector can be amplified to a suitable voltage range, and the DC noise of the pre-stage amplifier is effectively removed by the lock-in amplifier. An experimental system was set up to test the designed circuit. To ensure the consistency of the two channels, the method of exchange calibration was adopted in the test. It's drawn that the designed circuit is of high SNR, measuring accuracy and a large dynamic range from the test results. The NO concentration detection limit of vehicle emissions can reach 1ppm, and the detection precision is +/-15ppm.
Nanomaterials-based biosensors for detection of microorganisms and microbial toxins.
Sutarlie, Laura; Ow, Sian Yang; Su, Xiaodi
2017-04-01
Detection of microorganisms and microbial toxins is important for health and safety. Due to their unique physical and chemical properties, nanomaterials have been extensively used to develop biosensors for rapid detection of microorganisms with microbial cells and toxins as target analytes. In this paper, the design principles of nanomaterials-based biosensors for four selected analyte categories (bacteria cells, toxins, mycotoxins, and protozoa cells), closely associated with the target analytes' properties is reviewed. Five signal transducing methods that are less equipment intensive (colorimetric, fluorimetric, surface enhanced Raman scattering, electrochemical, and magnetic relaxometry methods) is described and compared for their sensory performance (in term oflimit of detection, dynamic range, and response time) for all analyte categories. In the end, the suitability of these five sensing principles for on-site or field applications is discussed. With a comprehensive coverage of nanomaterials, design principles, sensing principles, and assessment on the sensory performance and suitability for on-site application, this review offers valuable insight and perspective for designing suitable nanomaterials-based microorganism biosensors for a given application. Copyright © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Zhao, Zhengshan; Peytavi, Régis; Diaz-Quijada, Gerardo A.; Picard, Francois J.; Huletsky, Ann; Leblanc, Éric; Frenette, Johanne; Boivin, Guy; Veres, Teodor; Dumoulin, Michel M.; Bergeron, Michel G.
2008-01-01
Fabrication of microarray devices using traditional glass slides is not easily adaptable to integration into microfluidic systems. There is thus a need for the development of polymeric materials showing a high hybridization signal-to-background ratio, enabling sensitive detection of microbial pathogens. We have developed such plastic supports suitable for highly sensitive DNA microarray hybridizations. The proof of concept of this microarray technology was done through the detection of four human respiratory viruses that were amplified and labeled with a fluorescent dye via a sensitive reverse transcriptase PCR (RT-PCR) assay. The performance of the microarray hybridization with plastic supports made of PMMA [poly(methylmethacrylate)]-VSUVT or Zeonor 1060R was compared to that with high-quality glass slide microarrays by using both passive and microfluidic hybridization systems. Specific hybridization signal-to-background ratios comparable to that obtained with high-quality commercial glass slides were achieved with both polymeric substrates. Microarray hybridizations demonstrated an analytical sensitivity equivalent to approximately 100 viral genome copies per RT-PCR, which is at least 100-fold higher than the sensitivities of previously reported DNA hybridizations on plastic supports. Testing of these plastic polymers using a microfluidic microarray hybridization platform also showed results that were comparable to those with glass supports. In conclusion, PMMA-VSUVT and Zeonor 1060R are both suitable for highly sensitive microarray hybridizations. PMID:18784318
NASA Astrophysics Data System (ADS)
Vu, Thi N.; Klehr, Andreas; Sumpf, Bernd; Hoffmann, Thomas; Liero, Armin; Tränkle, Günther
2016-03-01
A master oscillator power amplifier system emitting alternatingly at two neighbored wavelengths around 965 nm is presented. As master oscillator (MO) a Y-branch DFB-laser is used. The two branches, which can be individually controlled, deliver the two wavelengths needed for a differential absorption measurement of water vapor. Adjusting the current through the DFB sections, the wavelength can be adjusted with respect to the targeted either "on" or "off" resonance, respectively wavelength λon or wavelength λoff. The emission of this laser is amplified in a tapered amplifier (TA). The ridge waveguide section of the TA acts as optical gate to generate short pulses with duration of 8 ns at a repetition rate of 25 kHz, the flared section is used for further amplification to reach peak powers up to 16 W suitable for micro-LIDAR (Light Detection and Ranging). The necessary pulse current supply user a GaN-transistor based driver electronics placed close to the power amplifier (PA). The spectral properties of the emission of the MO are preserved by the PA. A spectral line width smaller than 10 pm and a side mode suppression ratio (SMSR) of 37 dB are measured. These values meet the demands for water vapor absorption measurements under atmospheric conditions.
Design and validation of inert homemade explosive simulants for X-ray-based inspection systems
NASA Astrophysics Data System (ADS)
Faust, Anthony A.; Nacson, Sabatino; Koffler, Bruce; Bourbeau, Éric; Gagne, Louis; Laing, Robin; Anderson, C. J.
2014-05-01
Transport Canada (TC), the Canadian Armed Forces, and other public security agencies have an interest in the assessment of the potential utility of advanced explosives detection technologies to aid in the detection and interdiction of commercial grade, military grade, and homemade or improvised explosives (HME or IE). The availability of suitable, non-hazardous, non-toxic, explosive simulants is of concern when assessing the potential utility of such detection systems. Lack of simulants limits the training opportunities, and ultimately the detection probability, of security personnel using these systems. While simulants for commercial and military grade explosives are available for a wide variety of detection technologies, the design and production of materials to simulate improvised explosives has not kept pace with this emerging threat. Funded by TC and the Canadian Safety and Security Program, Defence Research and Development Canada (DRDC), Visiontec Systems, and Optosecurity engaged in an effort to develop inert, non-toxic Xray interrogation simulants for IE materials such as ammonium nitrate, potassium chlorate, and triacetone triperoxide. These simulants were designed to mimic key X-ray interrogation-relevant material properties of real improvised explosives, principally their bulk density and effective atomic number. Different forms of the simulants were produced and tested, simulating the different explosive threat formulations that could be encountered by front line security workers. These simulants comply with safety and stability requirements, and as best as possible match form and homogeneity. This paper outlines the research program, simulant design, and validation.
Mogler, Lukas; Franz, Florian; Wilde, Maurice; Huppertz, Laura M; Halter, Sebastian; Angerer, Verena; Moosmann, Bjoern; Auwärter, Volker
2018-05-04
Synthetic cannabinoids (SCs) are a structurally diverse class of new psychoactive substances. Most SCs used for recreational purposes are based on indole or indazole core structures. EG-018 (naphthalen-1-yl(9-pentyl-9H-carbazol-3-yl)methanone), EG-2201 ((9-(5-fluoropentyl)-9H-carbazol-3-yl)(naphthalen-1-yl)methanone) and MDMB-CHMCZCA (methyl 2-(9-(cyclohexylmethyl)-9H-carbazole-3-carboxamido)-3,3-dimethylbutanoate) are three representatives of a structural subclass of SCs, characterized by a carbazole core system. In vitro and in vivo phase I metabolism studies were conducted to identify the most suitable metabolites for the detection of these substances in urine screening. Detection and characterization of metabolites were performed by liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) and liquid chromatography-electrospray ionization-quadrupole time-of-flight mass spectrometry (LC-ESI-QToF-MS). Eleven in vivo metabolites were detected in urine samples positive for metabolites of EG-018 (n=8). A hydroxypentyl metabolite, most probably the 4-hydroxypentyl isomer, and an N-dealkylated metabolite mono-hydroxylated at the carbazole core system were most abundant. In vitro studies of EG-018 and EG-2201 indicated that oxidative defluorination of the 5-fluoropentyl side chain of EG-2201 as well as dealkylation led to common metabolites with EG-018. This has to be taken into account for interpretation of analytical findings. A differentiation between EG-018 and EG-2201 (n=1) uptake is possible by the detection of compound-specific in vivo phase I metabolites evaluated in this study. Out of 30 metabolites detected in urine samples of MDMB-CHMCZCA users (n=20), one metabolite mono-hydroxylated at the cyclohexyl methyl tail is considered the most suitable compound-specific consumption marker while a biotransformation product of mono-hydroxylation in combination with hydrolysis of the terminal methyl ester function provides best sensitivity due to its high abundance. This article is protected by copyright. All rights reserved.
Automatic non-proliferative diabetic retinopathy screening system based on color fundus image.
Xiao, Zhitao; Zhang, Xinpeng; Geng, Lei; Zhang, Fang; Wu, Jun; Tong, Jun; Ogunbona, Philip O; Shan, Chunyan
2017-10-26
Non-proliferative diabetic retinopathy is the early stage of diabetic retinopathy. Automatic detection of non-proliferative diabetic retinopathy is significant for clinical diagnosis, early screening and course progression of patients. This paper introduces the design and implementation of an automatic system for screening non-proliferative diabetic retinopathy based on color fundus images. Firstly, the fundus structures, including blood vessels, optic disc and macula, are extracted and located, respectively. In particular, a new optic disc localization method using parabolic fitting is proposed based on the physiological structure characteristics of optic disc and blood vessels. Then, early lesions, such as microaneurysms, hemorrhages and hard exudates, are detected based on their respective characteristics. An equivalent optical model simulating human eyes is designed based on the anatomical structure of retina. Main structures and early lesions are reconstructed in the 3D space for better visualization. Finally, the severity of each image is evaluated based on the international criteria of diabetic retinopathy. The system has been tested on public databases and images from hospitals. Experimental results demonstrate that the proposed system achieves high accuracy for main structures and early lesions detection. The results of severity classification for non-proliferative diabetic retinopathy are also accurate and suitable. Our system can assist ophthalmologists for clinical diagnosis, automatic screening and course progression of patients.
Walsh transforms and signal detection
NASA Technical Reports Server (NTRS)
Welch, L. R.
1977-01-01
The detection of signals using Walsh power spectral estimates is analyzed. In addition, a generalization of this method of estimation is evaluated. The conclusion is that Walsh transforms are not suitable tools for the detection of weak signals in noise.
Long-Wave Infrared Thermophotonic Imaging of Demineralization in Dental Hard Tissue
NASA Astrophysics Data System (ADS)
Ojaghi, A.; Parkhimchyk, A.; Tabatabaei, N.
2016-08-01
Dental caries remains the most prevalent chronic disease in both children and adults worldwide. To address this prevalence through disease prevention and management, dentists need tools capable of detecting caries at early stages of formation. Looking into the physics of light propagation in teeth, this study presents a clinically and commercially viable platform technology for thermophotonic detection of early dental caries using an inexpensive long-wavelength infrared (LWIR; 8 μm to 14 μm) camera. The developed system incorporates intensity-modulated light to generate a thermal-wave field inside enamel and uses the subsequent infrared emission of the thermal-wave field to detect early caries. It was found that the greater light absorption at caries sites shifts the thermal-wave field centroid, providing contrast between early caries and intact enamel. Use of LWIR detection band in dental samples is novel and beneficial over the conventional mid-wavelength infrared band (3 μm to 5 μm) as it suppresses the masking effect of the instantaneous radiative emission from subsurface features due to the minimal transmittance of enamel in the LWIR band. The efficacy of the LWIR system is verified though experiments carried out on nonbiological test samples as well as on teeth with natural and artificially induced caries. The results suggest that the developed LWIR technology is an affordable early dental caries detection system suitable for commercialization/translation to Dentistry.
NASA Astrophysics Data System (ADS)
Crawford, Bobby Grant
In an effort to field smaller and cheaper Uninhabited Aerial Vehicles (UAVs), the Army has expressed an interest in an ability of the vehicle to autonomously detect and avoid obstacles. Current systems are not suitable for small aircraft. NASA Langley Research Center has developed a vision sensing system that uses small semiconductor cameras. The feasibility of using this sensor for the purpose of autonomous obstacle avoidance by a UAV is the focus of the research presented in this document. The vision sensor characteristics are modeled and incorporated into guidance and control algorithms designed to generate flight commands based on obstacle information received from the sensor. The system is evaluated by simulating the response to these flight commands using a six degree-of-freedom, non-linear simulation of a small, fixed wing UAV. The simulation is written using the MATLAB application and runs on a PC. Simulations were conducted to test the longitudinal and lateral capabilities of the flight control for a range of airspeeds, camera characteristics, and wind speeds. Results indicate that the control system is suitable for obstacle avoiding flight control using the simulated vision system. In addition, a method for designing and evaluating the performance of such a system has been developed that allows the user to easily change component characteristics and evaluate new systems through simulation.
[MRI/TRUS fusion-guided prostate biopsy : Value in the context of focal therapy].
Franz, T; von Hardenberg, J; Blana, A; Cash, H; Baumunk, D; Salomon, G; Hadaschik, B; Henkel, T; Herrmann, J; Kahmann, F; Köhrmann, K-U; Köllermann, J; Kruck, S; Liehr, U-B; Machtens, S; Peters, I; Radtke, J P; Roosen, A; Schlemmer, H-P; Sentker, L; Wendler, J J; Witzsch, U; Stolzenburg, J-U; Schostak, M; Ganzer, R
2017-02-01
Several systems for MRI/TRUS fusion-guided biopsy of the prostate are commercially available. Many studies have shown superiority of fusion systems for tumor detection and diagnostic quality compared to random biopsy. The benefit of fusion systems in focal therapy of prostate cancer (PC) is less clear. Critical considerations of fusion systems for planning and monitoring of focal therapy of PC were investigated. A systematic literature review of available fusion systems for the period 2013-5/2016 was performed. A checklist of technical details, suitability for special anatomic situations and suitability for focal therapy was established by the German working group for focal therapy (Arbeitskreis fokale und Mikrotherapie). Eight fusion systems were considered (Artemis™, BioJet, BiopSee®, iSR´obot™ Mona Lisa, Hitachi HI-RVS, UroNav and Urostation®). Differences were found for biopsy mode (transrectal, perineal, both), fusion mode (elastic or rigid), navigation (image-based, electromagnetic sensor-based or mechanical sensor-based) and space requirements. Several consensus groups recommend fusion systems for focal therapy. Useful features are "needle tracking" and compatibility between fusion system and treatment device (available for Artemis™, BiopSee® and Urostation® with Focal One®; BiopSee®, Hitachi HI-RVS with NanoKnife®; BioJet, BiopSee® with cryoablation, brachytherapy). There are a few studies for treatment planning. However, studies on treatment monitoring after focal therapy are missing.
HgCdTe Detectors for Space and Science Imaging: General Issues and Latest Achievements
NASA Astrophysics Data System (ADS)
Gravrand, O.; Rothman, J.; Cervera, C.; Baier, N.; Lobre, C.; Zanatta, J. P.; Boulade, O.; Moreau, V.; Fieque, B.
2016-09-01
HgCdTe (MCT) is a very versatile material system for infrared (IR) detection, suitable for high performance detection in a wide range of applications and spectral ranges. Indeed, the ability to tailor the cutoff frequency as close as possible to the needs makes it a perfect candidate for high performance detection. Moreover, the high quality material available today, grown either by molecular beam epitaxy or liquid phase epitaxy, allows for very low dark currents at low temperatures, suitable for low flux detection applications such as science imaging. MCT has also demonstrated robustness to the aggressive environment of space and faces, therefore, a large demand for space applications. A satellite may stare at the earth, in which case detection usually involves a lot of photons, called a high flux scenario. Alternatively, a satellite may stare at outer space for science purposes, in which case the detected photon number is very low, leading to low flux scenarios. This latter case induces very strong constraints onto the detector: low dark current, low noise, (very) large focal plane arrays. The classical structure used to fulfill those requirements are usually p/ n MCT photodiodes. This type of structure has been deeply investigated in our laboratory for different spectral bands, in collaboration with the CEA Astrophysics lab. However, another alternative may also be investigated with low excess noise: MCT n/ p avalanche photodiodes (APD). This paper reviews the latest achievements obtained on this matter at DEFIR (LETI and Sofradir common laboratory) from the short wave infrared (SWIR) band detection for classical astronomical needs, to long wave infrared (LWIR) band for exoplanet transit spectroscopy, up to very long wave infrared (VLWIR) bands. The different available diode architectures ( n/ p VHg or p/ n, or even APDs) are reviewed, including different available ROIC architectures for low flux detection.
Su, Yachun; Yang, Yuting; Peng, Qiong; Zhou, Dinggang; Chen, Yun; Wang, Zhuqing; Xu, Liping; Que, Youxiong
2016-01-01
Smut is a fungal disease with widespread prevalence in sugarcane planting areas. Early detection and proper identification of Sporisorium scitamineum are essential in smut management practices. In the present study, four specific primers targeting the core effector Pep1 gene of S. scitamineum were designed. Optimal concentrations of Mg2+, primer and Bst DNA polymerase, the three important components of the loop-mediated isothermal amplification (LAMP) reaction system, were screened using a single factor experiment method and the L16(45) orthogonal experimental design. Hence, a LAMP system suitable for detection of S. scitamineum was established. High specificity of the LAMP method was confirmed by the assay of S. scitamineum, Fusarium moniliforme, Pestalotia ginkgo, Helminthospcrium sacchari, Fusarium oxysporum and endophytes of Yacheng05-179 and ROC22. The sensitivity of the LAMP method was equal to that of the conventional PCR targeting Pep1 gene and was 100 times higher than that of the conventional PCR assay targeting bE gene in S. scitamineum. The results suggest that this novel LAMP system has strong specificity and high sensitivity. This method not only provides technological support for the epidemic monitoring of sugarcane smut, but also provides a good case for development of similar detection technology for other plant pathogens. PMID:27035751
Sensitive gas chromatographic detection of acetaldehyde and acetone using a reduction gas detector
NASA Technical Reports Server (NTRS)
O'Hara, Dean; Singh, Hanwant B.
1988-01-01
The response of a newly available mercuric oxide Reduction Gas Detector (RGD-2) to subpicomole and larger quantities of acetaldehyde and acetone is tested. The RGD-2 is found to be capable of subpicomole detection for these carbonyls and is more sensitive than an FID (Flame Ionization Detector) by an order of magnitude. Operating parameters can be further optimized to make the RGD-2 some 20-40 times more sensitive than an FID. The detector is linear over a wide range and is easily adapted to a conventional gas chromatograph (GC). Such a GC-RGD-2 system should be suitable for atmospheric carbonyl measurements in clean as well as polluted environments.
Fraunhofer filters to reduce solar background for optical communications
NASA Technical Reports Server (NTRS)
Kerr, E. L.
1986-01-01
A wavelength that lies within a spectral interval of reduced solar emission (a Fraunhofer line) can carry optical communications with reduced interference from direct or reflected background sunlight. Suitable Fraunhofer lines are located within the tuning range of good candidate lasers. The laser should be tunable dynamically to track Doppler shifts in the sunlight incident on any solar system body that may appear in the background as viewed by the receiver. A Fraunhofer filter used with a direct-detection receiver should be tuned to match the Doppler shifts of the source and background. The required tuning calculated here for various situations is also required if, instead, one uses a heterodyne receiver with limited post-detection bandwidth.
Lacava, C; Cardea, I; Demirtzioglou, I; Khoja, A E; Ke, Li; Thomson, D J; Ruan, X; Zhang, F; Reed, G T; Richardson, D J; Petropoulos, P
2017-11-27
We present the characterization of a silicon Mach-Zehnder modulator with electrical packaging and show that it exhibits a large third-order intermodulation spurious-free dynamic range (> 100 dB Hz 2/3 ). This characteristic renders the modulator particularly suitable for the generation of high spectral efficiency discrete multi-tone signals and we experimentally demonstrate a single-channel, direct detection transmission system operating at 49.6 Gb/s, exhibiting a baseband spectral efficiency of 5 b/s/Hz. Successful transmission is demonstrated over various lengths of single mode fibre up to 40 km, without the need of any amplification or dispersion compensation.
A design of LED adaptive dimming lighting system based on incremental PID controller
NASA Astrophysics Data System (ADS)
He, Xiangyan; Xiao, Zexin; He, Shaojia
2010-11-01
As a new generation energy-saving lighting source, LED is applied widely in various technology and industry fields. The requirement of its adaptive lighting technology is more and more rigorous, especially in the automatic on-line detecting system. In this paper, a closed loop feedback LED adaptive dimming lighting system based on incremental PID controller is designed, which consists of MEGA16 chip as a Micro-controller Unit (MCU), the ambient light sensor BH1750 chip with Inter-Integrated Circuit (I2C), and constant-current driving circuit. A given value of light intensity required for the on-line detecting environment need to be saved to the register of MCU. The optical intensity, detected by BH1750 chip in real time, is converted to digital signal by AD converter of the BH1750 chip, and then transmitted to MEGA16 chip through I2C serial bus. Since the variation law of light intensity in the on-line detecting environment is usually not easy to be established, incremental Proportional-Integral-Differential (PID) algorithm is applied in this system. Control variable obtained by the incremental PID determines duty cycle of Pulse-Width Modulation (PWM). Consequently, LED's forward current is adjusted by PWM, and the luminous intensity of the detection environment is stabilized by self-adaptation. The coefficients of incremental PID are obtained respectively after experiments. Compared with the traditional LED dimming system, it has advantages of anti-interference, simple construction, fast response, and high stability by the use of incremental PID algorithm and BH1750 chip with I2C serial bus. Therefore, it is suitable for the adaptive on-line detecting applications.
Development of nanostars as a biocompatible tumor contrast agent: toward in vivo SERS imaging.
D'Hollander, Antoine; Mathieu, Evelien; Jans, Hilde; Vande Velde, Greetje; Stakenborg, Tim; Van Dorpe, Pol; Himmelreich, Uwe; Lagae, Liesbet
2016-01-01
The need for sensitive imaging techniques to detect tumor cells is an important issue in cancer diagnosis and therapy. Surface-enhanced Raman scattering (SERS), realized by chemisorption of compounds suitable for Raman spectroscopy onto gold nanoparticles, is a new method for detecting a tumor. As a proof of concept, we studied the use of biocompatible gold nanostars as sensitive SERS contrast agents targeting an ovarian cancer cell line (SKOV3). Due to a high intracellular uptake of gold nanostars after 6 hours of exposure, they could be detected and located with SERS. Using these nanostars for passive targeting after systemic injection in a xenograft mouse model, a detectable signal was measured in the tumor and liver in vivo. These signals were confirmed by ex vivo SERS measurements and darkfield microscopy. In this study, we established SERS nanostars as a highly sensitive contrast agent for tumor detection, which opens the potential for their use as a theranostic agent against cancer.
A Two-Stage Reconstruction Processor for Human Detection in Compressive Sensing CMOS Radar.
Tsao, Kuei-Chi; Lee, Ling; Chu, Ta-Shun; Huang, Yuan-Hao
2018-04-05
Complementary metal-oxide-semiconductor (CMOS) radar has recently gained much research attraction because small and low-power CMOS devices are very suitable for deploying sensing nodes in a low-power wireless sensing system. This study focuses on the signal processing of a wireless CMOS impulse radar system that can detect humans and objects in the home-care internet-of-things sensing system. The challenges of low-power CMOS radar systems are the weakness of human signals and the high computational complexity of the target detection algorithm. The compressive sensing-based detection algorithm can relax the computational costs by avoiding the utilization of matched filters and reducing the analog-to-digital converter bandwidth requirement. The orthogonal matching pursuit (OMP) is one of the popular signal reconstruction algorithms for compressive sensing radar; however, the complexity is still very high because the high resolution of human respiration leads to high-dimension signal reconstruction. Thus, this paper proposes a two-stage reconstruction algorithm for compressive sensing radar. The proposed algorithm not only has lower complexity than the OMP algorithm by 75% but also achieves better positioning performance than the OMP algorithm especially in noisy environments. This study also designed and implemented the algorithm by using Vertex-7 FPGA chip (Xilinx, San Jose, CA, USA). The proposed reconstruction processor can support the 256 × 13 real-time radar image display with a throughput of 28.2 frames per second.
A quantitative x-ray detection system for gold nanoparticle tumour biomarkers.
Ricketts, K; Castoldi, A; Guazzoni, C; Ozkan, C; Christodoulou, C; Gibson, A P; Royle, G J
2012-09-07
X-ray fluorescence techniques have proven beneficial for identifying and quantifying trace elements in biological tissues. A novel approach is being developed that employs x-ray fluorescence with an aim to locate heavy nanoparticles, such as gold, which are embedded into tissues. Such nanoparticles can be functionalized to act as markers for tumour characteristics to map the disease state, with the future aim of imaging them to inform cancer therapy regimes. The uptake of functionalized nanoparticles by cancer cells will also enable detection of small clusters of infiltrating cancer cells which are currently missed by commonly used imaging modalities. The novel system, consisting of an energy-resolving silicon drift detector with high spectral resolution, shows potential in both quantification of and sensitivity to nanoparticle concentrations typically found in tumours. A series of synchrotron measurements are presented; a linear relationship between fluorescence intensity and gold nanoparticle (GNP) concentration was found down to 0.005 mgAu ml(-1), the detection limit of the system. Successful use of a bench-top source, suitable for possible future clinical use, is also demonstrated, and found not to degrade the detection limit or accuracy of the GNP concentration measurement. The achieved system sensitivity suggests possible future clinical usefulness in measuring tumour uptake in vivo, particularly in shallow tumour sites and small animals, in ex vivo tissue and in 3D in vitro research samples.
Comparison of multi- and hyperspectral imaging data of leaf rust infected wheat plants
NASA Astrophysics Data System (ADS)
Franke, Jonas; Menz, Gunter; Oerke, Erich-Christian; Rascher, Uwe
2005-10-01
In the context of precision agriculture, several recent studies have focused on detecting crop stress caused by pathogenic fungi. For this purpose, several sensor systems have been used to develop in-field-detection systems or to test possible applications of remote sensing. The objective of this research was to evaluate the potential of different sensor systems for multitemporal monitoring of leaf rust (puccinia recondita) infected wheat crops, with the aim of early detection of infected stands. A comparison between a hyperspectral (120 spectral bands) and a multispectral (3 spectral bands) imaging system shows the benefits and limitations of each approach. Reflectance data of leaf rust infected and fungicide treated control wheat stand boxes (1sqm each) were collected before and until 17 days after inoculation. Plants were grown under controlled conditions in the greenhouse and measurements were taken under consistent illumination conditions. The results of mixture tuned matched filtering analysis showed the suitability of hyperspectral data for early discrimination of leaf rust infected wheat crops due to their higher spectral sensitivity. Five days after inoculation leaf rust infected leaves were detected, although only slight visual symptoms appeared. A clear discrimination between infected and control stands was possible. Multispectral data showed a higher sensitivity to external factors like illumination conditions, causing poor classification accuracy. Nevertheless, if these factors could get under control, even multispectral data may serve a good indicator for infection severity.
Amano, Hikaru; Ogawa, Hidekuni; Maki, Hiromichi; Tsukamoto, Sosuke; Yonezawa, Yoshiharu; Hahn, Allen W; Caldwell, W Morton
2011-01-01
We have been searching for a suitable frequency range for an electrical impedance measurement infusion solution drip monitoring system, which we have previously reported. This electrical impedance, which is formed between two electrodes wrapped around the infusion supply polyvinyl-chloride tube and around the drip chamber, is changed by the growth and fall of each drop of fluid. Thus, the drip rate can be detected by measuring this impedance. However, many different kinds of infusion solutions such as glucose, amino acid, soya oil, and lactated Ringers solution are used in hospitals and care facilities. Therefore, it was necessary to find a suitable frequency for driving the capacitance-change sensor with a wide range of infusion solutions. In this study, the sensor electrical impedance change of 16 infusion solutions was measured from 1 kHz up to 1 MHz. The drip impedance produced by 5% glucose solution, 10% glucose solution and soya oil indicated the maximum sensor output change at 10 kHz, 20 kHz, and 70 kHz, respectively. The other 13 infusion solutions increased up to 10 kHz, and were constant from 10 kHz to 1 MHz. However, the growth, fall, and drip rate of the drops of all the infusion solutions were monitored by measuring the impedance change from 10 kHz to 30 kHz. Our experimental results indicated that most suitable excitation range for the infusion monitoring system is from 10 kHz to 30 kHz. Thus, we can now fine-tune the system for optimal sensing.
Illicit drug detection using energy dispersive x-ray diffraction
NASA Astrophysics Data System (ADS)
Cook, E. J.; Griffiths, J. A.; Koutalonis, M.; Gent, C.; Pani, S.; Horrocks, J. A.; George, L.; Hardwick, S.; Speller, R.
2009-05-01
Illicit drugs are imported into countries in myriad ways, including via the postal system and courier services. An automated system is required to detect drugs in parcels for which X-ray diffraction is a suitable technique as it is non-destructive, material specific and uses X-rays of sufficiently high energy to penetrate parcels containing a range of attenuating materials. A database has been constructed containing the measured powder diffraction profiles of several thousand materials likely to be found in parcels. These include drugs, cutting agents, packaging and other innocuous materials. A software model has been developed using these data to predict the diffraction profiles which would be obtained by X-ray diffraction systems with a range of suggested detector (high purity germanium, CZT and scintillation), source and collimation options. The aim of the model was to identify the most promising system geometries, which was done with the aid of multivariate analysis (MVA). The most promising systems were constructed and tested. The diffraction profiles of a range of materials have been measured and used to both validate the model and to identify the presence of drugs in sample packages.
A small-angle x-ray scattering system with a vertical layout.
Wang, Zhen; Chen, Xiaowei; Meng, Lingpu; Cui, Kunpeng; Wu, Lihui; Li, Liangbin
2014-12-01
A small-angle x-ray scattering (SAXS) system with a vertical layout (V-SAXS) has been designed and constructed for in situ detection on nanostructures, which is well suitable for in situ study on self-assembly of nanoparticles at liquid interface and polymer processing. A steel-tower frame on a reinforced basement is built as the supporting skeleton for scattering beam path and detector platform, ensuring the system a high working stability and a high operating accuracy. A micro-focus x-ray source combining parabolic three-dimensional multi-layer mirror and scatteringless collimation system provides a highly parallel beam, which allows us to detect the very small angle range. With a sample-to-detector distance of 7 m, the largest measurable length scale is 420 nm in real space. With a large sample zone, it is possible to install different experimental setups such as film stretching machine, which makes the system perfect to follow the microstructures evolution of materials during processing. The capability of the V-SAXS on in situ study is tested with a drying experiment of a free latex droplet, which confirms our initial design.
Cell edge detection in JPEG2000 wavelet domain - analysis on sigmoid function edge model.
Punys, Vytenis; Maknickas, Ramunas
2011-01-01
Big virtual microscopy images (80K x 60K pixels and larger) are usually stored using the JPEG2000 image compression scheme. Diagnostic quantification, based on image analysis, might be faster if performed on compressed data (approx. 20 times less the original amount), representing the coefficients of the wavelet transform. The analysis of possible edge detection without reverse wavelet transform is presented in the paper. Two edge detection methods, suitable for JPEG2000 bi-orthogonal wavelets, are proposed. The methods are adjusted according calculated parameters of sigmoid edge model. The results of model analysis indicate more suitable method for given bi-orthogonal wavelet.
A multi-step system for screening and localization of hard exudates in retinal images
NASA Astrophysics Data System (ADS)
Bopardikar, Ajit S.; Bhola, Vishal; Raghavendra, B. S.; Narayanan, Rangavittal
2012-03-01
The number of people being affected by Diabetes mellitus worldwide is increasing at an alarming rate. Monitoring of the diabetic condition and its effects on the human body are therefore of great importance. Of particular interest is diabetic retinopathy (DR) which is a result of prolonged, unchecked diabetes and affects the visual system. DR is a leading cause of blindness throughout the world. At any point of time 25 - 44% of people with diabetes are afflicted by DR. Automation of the screening and monitoring process for DR is therefore essential for efficient utilization of healthcare resources and optimizing treatment of the affected individuals. Such automation would use retinal images and detect the presence of specific artifacts such as hard exudates, hemorrhages and soft exudates (that may appear in the image) to gauge the severity of DR. In this paper, we focus on the detection of hard exudates. We propose a two step system that consists of a screening step that classifies retinal images as normal or abnormal based on the presence of hard exudates and a detection stage that localizes these artifacts in an abnormal retinal image. The proposed screening step automatically detects the presence of hard exudates with a high sensitivity and positive predictive value (PPV ). The detection/localization step uses a k-means based clustering approach to localize hard exudates in the retinal image. Suitable feature vectors are chosen based on their ability to isolate hard exudates while minimizing false detections. The algorithm was tested on a benchmark dataset (DIARETDB1) and was seen to provide a superior performance compared to existing methods. The two-step process described in this paper can be embedded in a tele-ophthalmology system to aid with speedy detection and diagnosis of the severity of DR.
Zhou, Yu; Ren, Jie
2011-04-01
We put forward a new concept of software oversampling mapping system for electrocardiogram (ECG) to assist the research of the ECG inverse problem to improve the generality of mapping system and the quality of mapping signals. We then developed a conceptual system based on the traditional ECG detecting circuit, Labview and DAQ card produced by National Instruments, and at the same time combined the newly-developed oversampling method into the system. The results indicated that the system could map ECG signals accurately and the quality of the signals was good. The improvement of hardware and enhancement of software made the system suitable for mapping in different situations. So the primary development of the software for oversampling mapping system was successful and further research and development can make the system a powerful tool for researching ECG inverse problem.
Trellis coding with Continuous Phase Modulation (CPM) for satellite-based land-mobile communications
NASA Technical Reports Server (NTRS)
1989-01-01
This volume of the final report summarizes the results of our studies on the satellite-based mobile communications project. It includes: a detailed analysis, design, and simulations of trellis coded, full/partial response CPM signals with/without interleaving over various Rician fading channels; analysis and simulation of computational cutoff rates for coherent, noncoherent, and differential detection of CPM signals; optimization of the complete transmission system; analysis and simulation of power spectrum of the CPM signals; design and development of a class of Doppler frequency shift estimators; design and development of a symbol timing recovery circuit; and breadboard implementation of the transmission system. Studies prove the suitability of the CPM system for mobile communications.
Automatic visual monitoring of welding procedure in stainless steel kegs
NASA Astrophysics Data System (ADS)
Leo, Marco; Del Coco, Marco; Carcagnì, Pierluigi; Spagnolo, Paolo; Mazzeo, Pier Luigi; Distante, Cosimo; Zecca, Raffaele
2018-05-01
In this paper a system for automatic visual monitoring of welding process, in dry stainless steel kegs for food storage, is proposed. In the considered manufacturing process the upper and lower skirts are welded to the vessel by means of Tungsten Inert Gas (TIG) welding. During the process several problems can arise: 1) residuals on the bottom 2) darker weld 3) excessive/poor penetration and 4) outgrowths. The proposed system deals with all the four aforementioned problems and its inspection performances have been evaluated by using a large set of kegs demonstrating both the reliability in terms of defect detection and the suitability to be introduced in the manufacturing system in terms of computational costs.
NASA Astrophysics Data System (ADS)
Jin, Dayang; Yang, Fen; Chen, Zhongjiang; Yang, Sihua; Xing, Da
2017-09-01
The combination of phase-sensitive photoacoustic (PA) imaging of tissue viscoelasticity with the esophagus-adaptive PA endoscope (PAE) technique allows the characterization of the biomechanical and morphological changes in the early stage of esophageal disease with high accuracy. In this system, the tissue biomechanics and morphology are obtained by detecting the PA phase and PA amplitude information, respectively. The PAE has a transverse resolution of approximately 37 μm and an outer diameter of 1.2 mm, which is suitable for detecting rabbit esophagus. Here, an in-situ biomechanical and morphological study of normal and diseased rabbit esophagus (tumors of esophagus and reflux esophagitis) was performed. The in-situ findings were highly consistent with those observed by histology. In summary, we demonstrated the potential application of PAE for early clinical detection of esophageal diseases.
Real-time biochemical assay telemetering system
NASA Technical Reports Server (NTRS)
Kern, Roger G. (Inventor); Mintz, Frederick W. (Inventor); Richards, Gil F. (Inventor); Kidwell, David A. (Inventor)
1999-01-01
The present invention is an apparatus and a method of detecting a chemical released by perspiration, typically through sweat and broadcasting the detection to a receiver. The chemical may be a drug of abuse. The device which is attached to the skin of a subject contains labeled antibodies or label containing microspheres attached to antibodies. The labeled antibodies are bound to solid phase drug via antigen-antibody interaction. These labeled antibodies are displaced from the solid phase support to which they are bound by free drug molecules in the perspiration. These labeled antibodies then migrate through a spacer layer and are trapped by a layer containing a suitable selective binding material. The label is illuminated or excited by a light source and detected by a photodetector. The signal can be recorded, or transmitted to a remote radio monitor.
Computer vision techniques for rotorcraft low-altitude flight
NASA Technical Reports Server (NTRS)
Sridhar, Banavar; Cheng, Victor H. L.
1988-01-01
A description is given of research that applies techniques from computer vision to automation of rotorcraft navigation. The effort emphasizes the development of a methodology for detecting the ranges to obstacles in the region of interest based on the maximum utilization of passive sensors. The range map derived from the obstacle detection approach can be used as obstacle data for the obstacle avoidance in an automataic guidance system and as advisory display to the pilot. The lack of suitable flight imagery data, however, presents a problem in the verification of concepts for obstacle detection. This problem is being addressed by the development of an adequate flight database and by preprocessing of currently available flight imagery. Some comments are made on future work and how research in this area relates to the guidance of other autonomous vehicles.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ishida, T.; Hagihara, R.; Yugo, M.
1994-12-31
The authors have successfully developed and industrialized a new frequency-shift anti-islanding protection method using a twin-peak band-pass filter (BPF) for grid-interconnected photovoltaic (PV) systems. In this method, the power conditioner has a twin-peak BPF in a current feed back loop in place of the normal BPF. The new method works perfectly for various kinds of loads such as resistance, inductive and capacitive loads connected to the PV system. Furthermore, because there are no mis-detections, the system enables the most effective generation of electric energy from solar cells. A power conditioner equipped with this protection was officially certified as suitable formore » grid-interconnection.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pickrell, Gary; Scott, Brian
2014-06-30
This report covers the technical progress on the program “Novel Modified Optical Fibers for High Temperature In-Situ Miniaturized Gas Sensors in Advanced Fossil Energy Systems”, funded by the National Energy Technology Laboratory of the U.S. Department of Energy, and performed by the Materials Science & Engineering and Electrical & Computer Engineering Departments at Virginia Tech, and summarizes technical progress from July 1st, 2005 –June 30th, 2014. The objective of this program was to develop novel fiber materials for high temperature gas sensors based on evanescent wave absorption in optical fibers. This project focused on two primary areas: the study ofmore » a sapphire photonic crystal fiber (SPCF) for operation at high temperature and long wavelengths, and a porous glass based fiber optic sensor for gas detection. The sapphire component of the project focused on the development of a sapphire photonic crystal fiber, modeling of the new structures, fabrication of the optimal structure, development of a long wavelength interrogation system, testing of the optical properties, and gas and temperature testing of the final sensor. The fabrication of the 6 rod SPCF gap bundle (diameter of 70μm) with a hollow core was successfully constructed with lead-in and lead-out 50μm diameter fiber along with transmission and gas detection testing. Testing of the sapphire photonic crystal fiber sensor capabilities with the developed long wavelength optical system showed the ability to detect CO 2 at or below 1000ppm at temperatures up to 1000°C. Work on the porous glass sensor focused on the development of a porous clad solid core optical fiber, a hollow core waveguide, gas detection capabilities at room and high temperature, simultaneous gas species detection, suitable joining technologies for the lead-in and lead-out fibers and the porous sensor, sensor system sensitivity improvement, signal processing improvement, relationship between pore structure and fiber geometry to optical properties, and the development of a sensor packaging prototype for laboratory testing. Analysis and experiments determined that a bonding technique using a CO 2 laser is the most suitable joining technique. Pore morphology alteration showed that transmission improved with increasing annealing temperature (producing smaller pores), while the sensor response time increased and the mechanical strength decreased with increasing annealing temperature. Software was developed for data acquisition and signal processing to collect and interpret spectral gas absorption data. Gas detection on porous glass sensors was completed and the detection limit was evaluated using acetylene and was found to be around 1- 200ppm. A complete materials package for porous glass sensors was manufactured for testing.« less
Granado-Lorencio, F; Herrero-Barbudo, C; Blanco-Navarro, I; Pérez-Sacristán, B
2010-06-01
Our aim was to assess the suitability of ultra-high performance liquid chromatography (UHPLC) for the simultaneous determination of biomarkers of vitamins A (retinol, retinyl esters), E (alpha- and gamma-tocopherol), D (25-OH-vitamin D), and the major carotenoids in human serum to be used in clinical practice. UHPLC analysis was performed on HSS T3 column (2.1 x 100 mm; 1.8 microm) using gradient elution and UV-VIS detection. The system allows the simultaneous determination of retinol, retinyl palmitate, 25-OH-vitamin D, alpha- and gamma-tocopherol, lutein plus zeaxanthin, alpha-carotene, beta-carotene, alpha- and beta-cryptoxanthin and lycopene. The method showed a good linearity over the physiological range with an adequate accuracy in samples from quality control programs. Suitability of the method in clinical practice was tested by analyzing samples (n = 286) from patients. In conclusion, UHPLC constitutes a reliable approach for nutrient/biomarker profiling allowing the rapid, simultaneous and low-cost determination of vitamins A, E, and D (including vitamers and ester forms) and the major carotenoids in clinical practice.
Chen, Tzu Chieh; Lin, Yueh Ting; Lin, Chung Yi; Chen, W C; Chen, Meei Ru; Kao, Hui-Ling; Chyi, J I; Hsu, C H
2008-02-01
Epitaxial AlN films were prepared on GaN/sapphire using a helicon sputtering system at the low temperature of 300 degrees C. Surface acoustic wave (SAW) devices fabricated on AlN/GaN/sapphire exhibited superior characteristics compared with those made on GaN/sapphire. An oscillator using an AlN/GaN/sapphirebased SAW device is presented. The oscillation frequency decreased when the device was illuminated by ultraviolet (UV) radiation, and the downshift of the oscillation frequency increased with the illuminating UV power density. The results showed that the AlN/GaN/sapphire-layered structure SAW oscillators are suitable for visible blind UV detection and opened up the feasibility of developing remote UV sensors for different ranges of wavelengths on the III-nitrides.
Diagnosis of Periodontal Diseases by Biomarkers
NASA Astrophysics Data System (ADS)
Kido, Jun-Ichi; Hino, Mami; Bando, Mika; Hiroshima, Yuka
Many middle aged and old persons take periodontal diseases that mainly cause teeth loss and result in some systemic diseases. The prevention of periodontal diseases is very important for oral and systemic health, but the present diagnostic examination is not fully objective and suitable. To diagnose periodontal diseases exactly, some biomarkers shown inflammation, tissue degradation and bone resorption, in gingival crevicular fluid (GCF) and saliva are known. We demonstrated that GCF levels of calprotectin, inflammation-related protein, and carboxy-terminal propeptide of type I procollagen, bone metabolism-related protein, were associated with clinical condition of periodontal diseases, and suggested that these proteins may be useful biomarkers for periodontal diseases. Recently, determinations of genes and proteins by using microdevices are studied for diagnosis of some diseases. We detected calprotectin protein by chemiluminescent immunoassay on a microchip and showed the possibility of specific and quantitative detection of calprotectin in a very small amount of GCF. To determine plural markers in GCF by using microdevices contributes to develop accurate, objective diagnostic system of periodontal diseases.
Automatic, semi-automatic and manual validation of urban drainage data.
Branisavljević, N; Prodanović, D; Pavlović, D
2010-01-01
Advances in sensor technology and the possibility of automated long distance data transmission have made continuous measurements the preferable way of monitoring urban drainage processes. Usually, the collected data have to be processed by an expert in order to detect and mark the wrong data, remove them and replace them with interpolated data. In general, the first step in detecting the wrong, anomaly data is called the data quality assessment or data validation. Data validation consists of three parts: data preparation, validation scores generation and scores interpretation. This paper will present the overall framework for the data quality improvement system, suitable for automatic, semi-automatic or manual operation. The first two steps of the validation process are explained in more detail, using several validation methods on the same set of real-case data from the Belgrade sewer system. The final part of the validation process, which is the scores interpretation, needs to be further investigated on the developed system.
Toward Real-Time Classification of Wake Regimes from Sensor Measurements
NASA Astrophysics Data System (ADS)
Wang, Mengying; Hemati, Maziar S.
2017-11-01
Hydrodynamic signals can transmit information that can be used by marine swimmers to detect disturbances in the local environment. Biological swimmers are able to sense and detect these signals with their hydrodynamic receptor systems. Recently, similar flow sensing systems have been developed with an aim to improve swimming efficiency in human-engineered underwater vehicles. A key part of the sensing strategy is to first classify wake structures in the external fluid, then to execute suitable control actions accordingly. In our previous work, we showed that a variety of 2S and 2P wakes can be distinguished based on time signatures of surface sensor measurements. However, we assumed access to the full dataset. In this talk, we extend our previous findings to classify wake regimes from sensor measurements in real-time, using a recursive Fast Fourier Transform algorithm. Wakes in different dynamical regimes, which may also vary in time, can be distinguished using our approach. Our results provide insights for enhancing hydrodynamic sensory capabilities in human-engineered systems.
Spacecube: A Family of Reconfigurable Hybrid On-Board Science Data Processors
NASA Technical Reports Server (NTRS)
Flatley, Thomas P.
2015-01-01
SpaceCube is a family of Field Programmable Gate Array (FPGA) based on-board science data processing systems developed at the NASA Goddard Space Flight Center (GSFC). The goal of the SpaceCube program is to provide 10x to 100x improvements in on-board computing power while lowering relative power consumption and cost. SpaceCube is based on the Xilinx Virtex family of FPGAs, which include processor, FPGA logic and digital signal processing (DSP) resources. These processing elements are leveraged to produce a hybrid science data processing platform that accelerates the execution of algorithms by distributing computational functions to the most suitable elements. This approach enables the implementation of complex on-board functions that were previously limited to ground based systems, such as on-board product generation, data reduction, calibration, classification, eventfeature detection, data mining and real-time autonomous operations. The system is fully reconfigurable in flight, including data parameters, software and FPGA logic, through either ground commanding or autonomously in response to detected eventsfeatures in the instrument data stream.
Meynard, Jean-Baptiste; Chaudet, Herve; Green, Andrew D; Jefferson, Henry L; Texier, Gaetan; Webber, Daniel; Dupuy, Bruce; Boutin, Jean-Paul
2008-01-01
Background In recent years a wide variety of epidemiological surveillance systems have been developed to provide early identification of outbreaks of infectious disease. Each system has had its own strengths and weaknesses. In 2002 a Working Group of the Centers for Disease Control and Prevention (CDC) produced a framework for evaluation, which proved suitable for many public health surveillance systems. However this did not easily adapt to the military setting, where by necessity a variety of different parameters are assessed, different constraints placed on the systems, and different objectives required. This paper describes a proposed framework for evaluation of military syndromic surveillance systems designed to detect outbreaks of disease on operational deployments. Methods The new framework described in this paper was developed from the cumulative experience of British and French military syndromic surveillance systems. The methods included a general assessment framework (CDC), followed by more specific methods of conducting evaluation. These included Knowledge/Attitude/Practice surveys (KAP surveys), technical audits, ergonomic studies, simulations and multi-national exercises. A variety of military constraints required integration into the evaluation. Examples of these include the variability of geographical conditions in the field, deployment to areas without prior knowledge of naturally-occurring disease patterns, the differences in field sanitation between locations and over the length of deployment, the mobility of military forces, turnover of personnel, continuity of surveillance across different locations, integration with surveillance systems from other nations working alongside each other, compatibility with non-medical information systems, and security. Results A framework for evaluation has been developed that can be used for military surveillance systems in a staged manner consisting of initial, intermediate and final evaluations. For each stage of the process parameters for assessment have been defined and methods identified. Conclusion The combined experiences of French and British syndromic surveillance systems developed for use in deployed military forces has allowed the development of a specific evaluation framework. The tool is suitable for use by all nations who wish to evaluate syndromic surveillance in their own military forces. It could also be useful for civilian mobile systems or for national security surveillance systems. PMID:18447944
Biocontrol and Rapid Detection of Food-Borne Pathogens Using Bacteriophages and Endolysins
Bai, Jaewoo; Kim, You-Tae; Ryu, Sangryeol; Lee, Ju-Hoon
2016-01-01
Bacteriophages have been suggested as natural food preservatives as well as rapid detection materials for food-borne pathogens in various foods. Since Listeria monocytogenes-targeting phage cocktail (ListShield) was approved for applications in foods, numerous phages have been screened and experimentally characterized for phage applications in foods. A single phage and phage cocktail treatments to various foods contaminated with food-borne pathogens including E. coli O157:H7, Salmonella enterica, Campylobacter jejuni, Listeria monocytogenes, Staphylococcus aureus, Cronobacter sakazakii, and Vibrio spp. revealed that they have great potential to control various food-borne pathogens and may be alternative for conventional food preservatives. In addition, phage-derived endolysins with high host specificity and host lysis activities may be preferred to food applications rather than phages. For rapid detection of food-borne pathogens, cell-wall binding domains (CBDs) from endolysins have been suggested due to their high host-specific binding. Fluorescence-tagged CBDs have been successfully evaluated and suggested to be alternative materials of expensive antibodies for various detection applications. Most recently, reporter phage systems have been developed and tested to confirm their usability and accuracy for specific detection. These systems revealed some advantages like rapid detection of only viable pathogenic cells without interference by food components in a very short reaction time, suggesting that these systems may be suitable for monitoring of pathogens in foods. Consequently, phage is the next-generation biocontrol agent as well as rapid detection tool to confirm and even identify the food-borne pathogens present in various foods. PMID:27092128
External evaluation of the Dimension Vista 1500® intelligent lab system.
Bruneel, Arnaud; Dehoux, Monique; Barnier, Anne; Boutten, Anne
2012-09-01
Dimension Vista® analyzer combines four technologies (photometry, nephelometry, V-LYTE® integrated multisensor potentiometry, and LOCI® chemiluminescence) into one high-throughput system. We assessed analytical performance of assays routinely performed in our emergency laboratory according to the VALTEC protocol, and practicability. Precision was good for most parameters. Analytical domain was large and suitable for undiluted analysis in most clinical settings encountered in our hospital. Data were comparable and correlated to our routine analyzers (Roche Modular DP®, Abbott AXSYM®, Siemens Dimension® RxL, and BN ProSpec®). Performance of nephelometric and LOCI modules was excellent. Functional sensitivity of high-sensitivity C-reactive protein and cardiac troponin I were 0.165 mg/l and 0.03 ng/ml, respectively (coefficient of variation; CV < 10%). The influence of interfering substances (i.e., hemoglobin, bilirubin, or lipids) was moderate, and Dimension Vista® specifically alerted for interference according to HIL (hemolysis, icterus, lipemia) indices. Good instrument performance and full functionality (no reagent or sample carryover in the conditions evaluated, effective sample-volume detection, and clot detection) were confirmed. Simulated routine testing demonstrated excellent practicability, throughput, ease of use of software and security. Performance and practicability of Dimension Vista® are highly suitable for both routine and emergency use. Since no volume detection and thus no warning is available on limited sample racks, pediatric samples require special caution to the Siemens protocol to be analyzed in secured conditions. Our experience in routine practice is also discussed, i.e., the impact of daily workload, "manual" steps resulting from dilutions and pediatric samples, maintenances, flex hydration on instrument's performance on throughput and turnaround time. © 2012 Wiley Periodicals, Inc.
Deep groundwater and potential subsurface habitats beneath an Antarctic dry valley
Mikucki, J. A.; Auken, E.; Tulaczyk, S.; Virginia, R. A.; Schamper, C.; Sørensen, K. I.; Doran, P. T.; Dugan, H.; Foley, N.
2015-01-01
The occurrence of groundwater in Antarctica, particularly in the ice-free regions and along the coastal margins is poorly understood. Here we use an airborne transient electromagnetic (AEM) sensor to produce extensive imagery of resistivity beneath Taylor Valley. Regional-scale zones of low subsurface resistivity were detected that are inconsistent with the high resistivity of glacier ice or dry permafrost in this region. We interpret these results as an indication that liquid, with sufficiently high solute content, exists at temperatures well below freezing and considered within the range suitable for microbial life. These inferred brines are widespread within permafrost and extend below glaciers and lakes. One system emanates from below Taylor Glacier into Lake Bonney and a second system connects the ocean with the eastern 18 km of the valley. A connection between these two basins was not detected to the depth limitation of the AEM survey (∼350 m). PMID:25919365
Robust Video Stabilization Using Particle Keypoint Update and l1-Optimized Camera Path
Jeon, Semi; Yoon, Inhye; Jang, Jinbeum; Yang, Seungji; Kim, Jisung; Paik, Joonki
2017-01-01
Acquisition of stabilized video is an important issue for various type of digital cameras. This paper presents an adaptive camera path estimation method using robust feature detection to remove shaky artifacts in a video. The proposed algorithm consists of three steps: (i) robust feature detection using particle keypoints between adjacent frames; (ii) camera path estimation and smoothing; and (iii) rendering to reconstruct a stabilized video. As a result, the proposed algorithm can estimate the optimal homography by redefining important feature points in the flat region using particle keypoints. In addition, stabilized frames with less holes can be generated from the optimal, adaptive camera path that minimizes a temporal total variation (TV). The proposed video stabilization method is suitable for enhancing the visual quality for various portable cameras and can be applied to robot vision, driving assistant systems, and visual surveillance systems. PMID:28208622
Comparison of two MAC protocols based on LEO satellite networks
NASA Astrophysics Data System (ADS)
Guan, Mingxiang; Wang, Ruichun
2009-12-01
With the development of LEO satellite communication, it is the basic requirement that various kinds of services will be provided. Considering that weak channel collision detection ability, long propagation delay and heavy load in LEO satellite communication system, a valid adaptive access control protocol APRMA is proposed. Different access probability functions for different services are obtained and appropriate access probabilities for voice and data users are updated slot by slot based on the estimation of the voice traffic and the channel status. Finally simulation results demonstrate that the performance of system is improved by the APRMA compared with the conventional PRMA, with an acceptable trade-off between QoS of voice and delay of data. Also the APRMA protocol will be suitable for HAPS (high altitude platform station) with the characters of weak channel collision detection ability, long propagation delay and heavy load.
Malvestio, Irene; Kreuz, Thomas; Andrzejak, Ralph G
2017-08-01
The detection of directional couplings between dynamics based on measured spike trains is a crucial problem in the understanding of many different systems. In particular, in neuroscience it is important to assess the connectivity between neurons. One of the approaches that can estimate directional coupling from the analysis of point processes is the nonlinear interdependence measure L. Although its efficacy has already been demonstrated, it still needs to be tested under more challenging and realistic conditions prior to an application to real data. Thus, in this paper we use the Hindmarsh-Rose model system to test the method in the presence of noise and for different spiking regimes. We also examine the influence of different parameters and spike train distances. Our results show that the measure L is versatile and robust to various types of noise, and thus suitable for application to experimental data.
Condition sensor system and method
NASA Technical Reports Server (NTRS)
Polhemus, J. T.; Morgan, J. E.; Mandell, A. (Inventor)
1978-01-01
The condition sensor system comprises a condition detector which produces a pulse when a parameter of the monitored condition exceeds a desired threshold. A resettable condition counter counts each pulse. A resettable timer is preset to produce a particular time frame. The counter produces a condition signal when the accumulated number of pulses within the time frame is equal to or greater than a preset count. Control means responsive to the incoming pulses and to the condition signal produce control signals that control utilization devices. After a suitable delay, the last detected pulse simultaneously resets the pulse counter and the timer, and prepares them for sensing another condition occurrence within the time frame. The invention has particular utility in the process of detecting rocking motions of blind people. A controlled, audible, bio-feedback signal is provided which constitutes a warning to the blind person that he is rocking.
NASA Astrophysics Data System (ADS)
Malvestio, Irene; Kreuz, Thomas; Andrzejak, Ralph G.
2017-08-01
The detection of directional couplings between dynamics based on measured spike trains is a crucial problem in the understanding of many different systems. In particular, in neuroscience it is important to assess the connectivity between neurons. One of the approaches that can estimate directional coupling from the analysis of point processes is the nonlinear interdependence measure L . Although its efficacy has already been demonstrated, it still needs to be tested under more challenging and realistic conditions prior to an application to real data. Thus, in this paper we use the Hindmarsh-Rose model system to test the method in the presence of noise and for different spiking regimes. We also examine the influence of different parameters and spike train distances. Our results show that the measure L is versatile and robust to various types of noise, and thus suitable for application to experimental data.
Monitoring coastal inundation with Synthetic Aperture Radar satellite data
Suzuoki, Yukihiro; Rangoonwala, Amina; Ramsey, Elijah W.
2011-01-01
When mapping day-to-day coastal inundation extents, results indicate that SAR systems operating at C-band frequencies are not as effective as those operating at L-band frequencies; however, multiple factors not related to frequency also reduced the effectiveness of C-Band in detecting subcanopy inundation. C-band has performed and continues to perform exceedingly well in applications for response to dramatic events and when strategic collections are available; however, L-band seems to be more suitable for day-to-day mapping of coastal inundation.
FEMOS - Advanced Neutron Monitor System for Waste Management
DOE Office of Scientific and Technical Information (OSTI.GOV)
Simon, G.G.; Sokcic-Kostic, M.
2006-07-01
FEMOS is a specially developed monitor to detect fissile materials for waste characterisation and it is also suitable to identify the main neutron emitters. The latest measuring prototype is in routine operation at FZK-HDB (Germany) for determining Plutonium content and alpha activity in 2001 and 4001 drums from the reprocessing plant Karlsruhe (WAK). Authorities license the measurement procedure. Routine measurements conducted over a period of about 6 years and the results show that all specified prerequisites are met with the required reliability. (authors)
Kirov, Ilya; Van Laere, Katrijn; De Riek, Jan; De Keyser, Ellen; Van Roy, Nadine; Khrustaleva, Ludmila
2014-01-01
In order to anchor Rosa linkage groups to physical chromosomes, a combination of the Tyramide-FISH technology and the modern molecular marker system based on High Resolution Melting (HRM) is an efficient approach. Although, Tyramide-FISH is a very promising technique for the visualization of short DNA probes, it is very challenging for plant species with small chromosomes such as Rosa. In this study, we successfully applied the Tyramide-FISH technique for Rosa and compared different detection systems. An indirect detection system exploiting biotinylated tyramides was shown to be the most suitable technique for reliable signal detection. Three gene fragments with a size of 1100 pb–1700 bp (Phenylalanine Ammonia Lyase, Pyrroline-5-Carboxylate Synthase and Orcinol O-Methyl Transferase) have been physically mapped on chromosomes 7, 4 and 1, respectively, of Rosa wichurana. The signal frequency was between 25% and 40%. HRM markers of these 3 gene fragments were used to include the gene fragments on the existing genetic linkage map of Rosa wichurana. As a result, three linkage groups could be anchored to their physical chromosomes. The information was used to check for synteny between the Rosa chromosomes and Fragaria. PMID:24755945
Quantitative surface-enhanced resonance Raman scattering of phthalocyanine-labelled oligonucleotides
Macaskill, A.; Chernonosov, A. A.; Koval, V. V.; Lukyanets, E. A.; Fedorova, O. S.; Smith, W. E.; Faulds, K.; Graham, D.
2007-01-01
The evaluation of phthalocyanine labels for the surface-enhanced resonance Raman scattering (SERRS) detection of oligonucleotides is reported. Three phthalocyanine-labelled oligonucleotides were assessed, each containing a different metal centre. Detection limits for each labelled oligonucleotide were determined using two excitation frequencies where possible. Limits of detection as low as 2.8 × 10−11 mol. dm−3 were obtained which are comparable to standard fluorescently labelled probes used in previous SERRS studies. The identification of two phthalocyanine-labelled oligonucleotides without separation was also demonstrated indicating their suitability for multiplexing. This study extends the range of labels suitable for quantitative surface-enhanced resonance Raman scattering with silver nanoparticles and offers more flexibility and choice when considering SERRS for quantitative DNA detection. PMID:17289751
Change Analysis in Structural Laser Scanning Point Clouds: The Baseline Method
Shen, Yueqian; Lindenbergh, Roderik; Wang, Jinhu
2016-01-01
A method is introduced for detecting changes from point clouds that avoids registration. For many applications, changes are detected between two scans of the same scene obtained at different times. Traditionally, these scans are aligned to a common coordinate system having the disadvantage that this registration step introduces additional errors. In addition, registration requires stable targets or features. To avoid these issues, we propose a change detection method based on so-called baselines. Baselines connect feature points within one scan. To analyze changes, baselines connecting corresponding points in two scans are compared. As feature points either targets or virtual points corresponding to some reconstructable feature in the scene are used. The new method is implemented on two scans sampling a masonry laboratory building before and after seismic testing, that resulted in damages in the order of several centimeters. The centres of the bricks of the laboratory building are automatically extracted to serve as virtual points. Baselines connecting virtual points and/or target points are extracted and compared with respect to a suitable structural coordinate system. Changes detected from the baseline analysis are compared to a traditional cloud to cloud change analysis demonstrating the potential of the new method for structural analysis. PMID:28029121
Change Analysis in Structural Laser Scanning Point Clouds: The Baseline Method.
Shen, Yueqian; Lindenbergh, Roderik; Wang, Jinhu
2016-12-24
A method is introduced for detecting changes from point clouds that avoids registration. For many applications, changes are detected between two scans of the same scene obtained at different times. Traditionally, these scans are aligned to a common coordinate system having the disadvantage that this registration step introduces additional errors. In addition, registration requires stable targets or features. To avoid these issues, we propose a change detection method based on so-called baselines. Baselines connect feature points within one scan. To analyze changes, baselines connecting corresponding points in two scans are compared. As feature points either targets or virtual points corresponding to some reconstructable feature in the scene are used. The new method is implemented on two scans sampling a masonry laboratory building before and after seismic testing, that resulted in damages in the order of several centimeters. The centres of the bricks of the laboratory building are automatically extracted to serve as virtual points. Baselines connecting virtual points and/or target points are extracted and compared with respect to a suitable structural coordinate system. Changes detected from the baseline analysis are compared to a traditional cloud to cloud change analysis demonstrating the potential of the new method for structural analysis.
Microcontact imprinted surface plasmon resonance sensor for myoglobin detection.
Osman, Bilgen; Uzun, Lokman; Beşirli, Necati; Denizli, Adil
2013-10-01
In this study, we prepared surface plasmon resonance (SPR) sensor using the molecular imprinting technique for myoglobin detection in human serum. For this purpose, we synthesized myoglobin imprinted poly(hydroxyethyl methacrylate-N-methacryloyl-l-tryptophan methyl ester) [poly(HEMA-MATrp)] nanofilm on the surface of SPR sensor. We also synthesized non-imprinted poly(HEMA-MATrp) nanofilm without myoglobin for the control experiments. The SPR sensor was characterized with contact angle measurements, atomic force microscopy, X-ray photoelectron spectroscopy, and ellipsometry. We investigated the effectiveness of the sensor using the SPR system. We evaluated the ability of SPR sensor to sense myoglobin with myoglobin solutions (pH7.4, phosphate buffer) in different concentration range and in the serum taken from a patient with acute myocardial infarction. We found that the Langmuir adsorption model was the most suitable for the sensor system. The detection limit was 87.6 ng/mL. In order to show the selectivity of the SPR sensor, we investigated the competitive detection of myoglobin, lysozyme, cytochrome c and bovine serum albumin. The results showed that the SPR sensor has high selectivity and sensitivity for myoglobin. Copyright © 2013. Published by Elsevier B.V.
Yuan, Jipei; Guo, Weiwei; Yang, Xiurong; Wang, Erkang
2009-01-01
A sensing system based on the photoinduced electron transfer of quantum dots (QDs) was designed to measure the interaction of anticancer drug and DNA, taking mitoxantrone (MTX) as a model drug. MTX adsorbed on the surface of QDs can quench the photoluminescence (PL) of QDs through the photoinduced electron-transfer process; and then the addition of DNA will bring the restoration of QDs PL intensity, as DNA can bind with MTX and remove it from QDs. Sensitive detection of MTX with the detection limit of 10 nmol L(-1) and a linear detection range from 10 nmol L(-1) to 4.5 micromol L(-1) was achieved. The dependence of PL intensity on DNA amount was successfully utilized to investigate the interactions between MTX and DNA. Both the binding constants and the sizes of binding site of MTX-DNA interactions were calculated based on the equations deduced for the PL recovery process. The binding constant obtained in our experiment was generally consistent with previous reports. The sensitive and speedy detection of MTX as well as the avoidance of modification or immobilization process made this system suitable and promising in the drug-DNA interaction studies.
Ma, Qinglin; Liu, Houming; Ye, Feidi; Xiang, Guangxin; Shan, Wanshui; Xing, Wanli
2017-12-01
To definitively diagnose active pulmonary Tuberculosis (TB), Mycobacterium tuberculosis complex (MTBC) bacilli must be identified within clinical specimens from patients. In this study, we introduced a rapid and visual detection method of MTBC using recombinase polymerase amplification (RPA) combined with lateral flow (LF) strips. The LF-RPA assay, read results with naked eyes, could detect as few as 5 genome copies of M. tuberculosis H37Rv (ATCC 27294) per reaction and had no cross-reactions with other control bacteria even using excessive amount of template DNA. The system could work well at a broad range of temperature 25-45 °C and reach detectable level even within 5 min. When testing a total of 137 clinical specimens, the sensitivity and specificity of the LF-RPA assay were 100% (95% CI: 95.94%-100%) and 97.92% (95% CI: 88.93%-99.95%), respectively, compared to culture identification method. Therefore, the LF-RPA system we have demonstrated is a rapid, simple, robust method for MTBC detection which, subject to the availability of a suitable sample extraction method, has the potentiality to diagnose TB at the point-of-care testing. Copyright © 2017 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Krumpe, Tanja; Walter, Carina; Rosenstiel, Wolfgang; Spüler, Martin
2016-08-01
Objective. In this study, the feasibility of detecting a P300 via an asynchronous classification mode in a reactive EEG-based brain-computer interface (BCI) was evaluated. The P300 is one of the most popular BCI control signals and therefore used in many applications, mostly for active communication purposes (e.g. P300 speller). As the majority of all systems work with a stimulus-locked mode of classification (synchronous), the field of applications is limited. A new approach needs to be applied in a setting in which a stimulus-locked classification cannot be used due to the fact that the presented stimuli cannot be controlled or predicted by the system. Approach. A continuous observation task requiring the detection of outliers was implemented to test such an approach. The study was divided into an offline and an online part. Main results. Both parts of the study revealed that an asynchronous detection of the P300 can successfully be used to detect single events with high specificity. It also revealed that no significant difference in performance was found between the synchronous and the asynchronous approach. Significance. The results encourage the use of an asynchronous classification approach in suitable applications without a potential loss in performance.
Multianalyte detection using a capillary-based flow immunosensor.
Narang, U; Gauger, P R; Kusterbeck, A W; Ligler, F S
1998-01-01
A highly sensitive, dual-analyte detection system using capillary-based immunosensors has been designed for explosive detection. This model system consists of two capillaries, one coated with antibodies specific for 2,4,6-trinitrotoluene (TNT) and the other specific for hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) combined into a single device. The fused silica capillaries are prepared by coating anti-TNT and anti-RDX antibodies onto the silanized inner walls using a hetero-bifunctional crosslinker. After immobilization, the antibodies are saturated with a suitable fluorophorelabeled antigen. A "T" connector is used to continuously flow the buffer solution through the individual capillaries. To perform the assay, an aliquot of TNT or RDX or a mixture of the two analytes is injected into the continuous flow stream. In each capillary, the target analyte displaces the fluorophore-labeled antigen from the binding pocket of the antibody. The labeled antigen displaced from either capillary is detected downstream using two portable spectrofluorometers. The limits of detection for TNT and RDX in the multi-analyte formate are 44 fmol (100 microliters of 0.1 ng/ml TNT solution) and 224 fmol (100 microliters of 0.5 ng/ml RDX solution), respectively. The entire assay for both analytes can be performed in less than 3 min.
Airborne Doppler radar detection of low altitude windshear
NASA Technical Reports Server (NTRS)
Bracalente, Emedio M.; Jones, William R.; Britt, Charles L.
1990-01-01
As part of an integrated windshear program, the Federal Aviation Administration, jointly with NASA, is sponsoring a research effort to develop airborne sensor technology for the detection of low altitude windshear during aircraft take-off and landing. One sensor being considered is microwave Doppler radar operating at X-band or above. Using a Microburst/Clutter/Radar simulation program, a preliminary feasibility study was conducted to assess the performance of Doppler radars for this application. Preliminary results from this study are presented. Analysis show, that using bin-to-bin Automatic Gain Control (AGC), clutter filtering, limited detection range, and suitable antenna tilt management, windshear from a wet microburst can be accurately detected 10 to 65 seconds (.75 to 5 km) in front of the aircraft. Although a performance improvement can be obtained at higher frequency, the baseline X-band system that was simulated detected the presence of a windshear hazard for the dry microburst. Although this study indicates the feasibility of using an airborne Doppler radar to detect low altitude microburst windshear, further detailed studies, including future flight experiments, will be required to completely characterize the capabilities and limitations.
Oroval, Mar; Coronado-Puchau, Marc; Langer, Judith; Sanz-Ortiz, Marta Norah; Ribes, Ángela; Aznar, Elena; Coll, Carmen; Marcos, María Dolores; Sancenón, Félix; Liz-Marzán, Luis M; Martínez-Máñez, Ramón
2016-09-12
We present herein a novel combination of gated mesoporous silica nanoparticles (MSNs) and surface-enhanced Raman scattering (SERS) for sensing applications. As a proof-of-concept, we show the design of a system comprising MSNs loaded with crystal violet (CV), a molecule with high Raman cross section acting as SERS reporter, and capped with either a suitable DNA sequence for the detection of Mycoplasma genomic DNA or with an aptamer that selectively coordinates cocaine. In both cases the presence of the corresponding target analyte in solution (i.e., genomic DNA or cocaine) resulted in the release of CV. CV delivery was detected by SERS upon adsorption on gold nanotriangles (AuNTs), which display an efficient electromagnetic field enhancement and a high colloidal stability. By using this novel procedure a limit of detection of at least 30 copies DNA per μL was determined for the detection of Mycoplasma genomic DNA, whereas cocaine was detected at concentrations as low as 10 nm. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Struchen, R; Vial, F; Andersson, M G
2017-04-26
Delayed reporting of health data may hamper the early detection of infectious diseases in surveillance systems. Furthermore, combining multiple data streams, e.g. aiming at improving a system's sensitivity, can be challenging. In this study, we used a Bayesian framework where the result is presented as the value of evidence, i.e. the likelihood ratio for the evidence under outbreak versus baseline conditions. Based on a historical data set of routinely collected cattle mortality events, we evaluated outbreak detection performance (sensitivity, time to detection, in-control run length) under the Bayesian approach among three scenarios: presence of delayed data reporting, but not accounting for it; presence of delayed data reporting accounted for; and absence of delayed data reporting (i.e. an ideal system). Performance on larger and smaller outbreaks was compared with a classical approach, considering syndromes separately or combined. We found that the Bayesian approach performed better than the classical approach, especially for the smaller outbreaks. Furthermore, the Bayesian approach performed similarly well in the scenario where delayed reporting was accounted for to the scenario where it was absent. We argue that the value of evidence framework may be suitable for surveillance systems with multiple syndromes and delayed reporting of data.
Detection of hydrogen peroxide based on long-path absorption spectroscopy using a CW EC-QCL
NASA Astrophysics Data System (ADS)
Sanchez, N. P.; Yu, Y.; Dong, L.; Griffin, R.; Tittel, F. K.
2016-02-01
A sensor system based on a CW EC-QCL (mode-hop-free range 1225-1285 cm-1) coupled with long-path absorption spectroscopy was developed for the monitoring of gas-phase hydrogen peroxide (H2O2) using an interference-free absorption line located at 1234.055 cm-1. Wavelength modulation spectroscopy (WMS) with second harmonic detection was implemented for data processing. Optimum levels of pressure and modulation amplitude of the sensor system led to a minimum detection limit (MDL) of 25 ppb using an integration time of 280 sec. The selected absorption line for H2O2, which exhibits no interference from H2O, makes this sensor system suitable for sensitive and selective monitoring of H2O2 levels in decontamination and sterilization processes based on Vapor Phase Hydrogen Peroxide (VPHP) units, in which a mixture of H2O and H2O2 is generated. Furthermore, continuous realtime monitoring of H2O2 concentrations in industrial facilities employing this species can be achieved with this sensing system in order to evaluate average permissible exposure levels (PELs) and potential exceedances of guidelines established by the US Occupational Safety and Health Administration for H2O2.
Kashiha, Mohammad Amin; Green, Angela R; Sales, Tatiana Glogerley; Bahr, Claudia; Berckmans, Daniel; Gates, Richard S
2014-10-01
Image processing systems have been widely used in monitoring livestock for many applications, including identification, tracking, behavior analysis, occupancy rates, and activity calculations. The primary goal of this work was to quantify image processing performance when monitoring laying hens by comparing length of stay in each compartment as detected by the image processing system with the actual occurrences registered by human observations. In this work, an image processing system was implemented and evaluated for use in an environmental animal preference chamber to detect hen navigation between 4 compartments of the chamber. One camera was installed above each compartment to produce top-view images of the whole compartment. An ellipse-fitting model was applied to captured images to detect whether the hen was present in a compartment. During a choice-test study, mean ± SD success detection rates of 95.9 ± 2.6% were achieved when considering total duration of compartment occupancy. These results suggest that the image processing system is currently suitable for determining the response measures for assessing environmental choices. Moreover, the image processing system offered a comprehensive analysis of occupancy while substantially reducing data processing time compared with the time-intensive alternative of manual video analysis. The above technique was used to monitor ammonia aversion in the chamber. As a preliminary pilot study, different levels of ammonia were applied to different compartments while hens were allowed to navigate between compartments. Using the automated monitor tool to assess occupancy, a negative trend of compartment occupancy with ammonia level was revealed, though further examination is needed. ©2014 Poultry Science Association Inc.
Investigations related to evaluation of ultramicrofluorometer
NASA Technical Reports Server (NTRS)
Whitcomb, B.
1981-01-01
High resolution emission and excitation fluorescent spectra were obtained for several samples in an effort to determine the optimum operational design for the instrument. The instrument was used to determine the required nature of a sample which could be detected, and in so doing, several different sample preparation techniques were considered. Numerous experiments were performed to determine the capabilities of the instrument with regard to the detection of suitably prepared virus specimens. Significant results were obtained in several areas. The fluorescent spectra indicated that substantial changes in the laser might be used advantageously to greatly improve the performance of the instrument. In the existing configuration, the instrument was shown to be capable of detecting the presence of suitably prepared virus samples.
Helicase dependent OnChip-amplification and its use in multiplex pathogen detection.
Andresen, Dennie; von Nickisch-Rosenegk, Markus; Bier, Frank F
2009-05-01
The need for fast, specific and sensitive multiparametric detection methods is an ever growing demand in molecular diagnostics. Here we report on a newly developed method, the helicase dependent OnChip amplification (OnChip-HDA). This approach integrates the analysis and detection in one single reaction thus leading to time and cost savings in multiparametric analysis. HDA is an isothermal amplification method that is not depending on thermocycling as known from PCR due to the helicases' ability to unwind DNA double-strands. We have combined the HDA with microarray based detection, making it suitable for multiplex detection. As an example we used the OnChip HDA in single and multiplex amplifications for the detection of the two pathogens N. gonorrhoeae and S. aureus directly on surface bound primers. We have successfully shown the OnChip-HDA and applied it for single- and duplex-detection of the pathogens N. gonorrhoeae and S. aureus. We have developed a new method, the OnChip-HDA for the multiplex detection of pathogens. Its simplicity in reaction setup and potential for miniaturization and multiparametric analysis is advantageous for the integration in miniaturized Lab on Chip systems, e.g. needed in point of care diagnostics.
Information processing requirements for on-board monitoring of automatic landing
NASA Technical Reports Server (NTRS)
Sorensen, J. A.; Karmarkar, J. S.
1977-01-01
A systematic procedure is presented for determining the information processing requirements for on-board monitoring of automatic landing systems. The monitoring system detects landing anomalies through use of appropriate statistical tests. The time-to-correct aircraft perturbations is determined from covariance analyses using a sequence of suitable aircraft/autoland/pilot models. The covariance results are used to establish landing safety and a fault recovery operating envelope via an event outcome tree. This procedure is demonstrated with examples using the NASA Terminal Configured Vehicle (B-737 aircraft). The procedure can also be used to define decision height, assess monitoring implementation requirements, and evaluate alternate autoland configurations.
Design of two wheel self balancing car
NASA Astrophysics Data System (ADS)
He, Chun-hong; Ren, Bin
2018-02-01
This paper proposes a design scheme of the two-wheel self-balancing dolly, the integration of the gyroscope and accelerometer MPU6050 constitutes the car position detection device.System selects 32-bit MCU stmicroelectronics company as the control core, completed the processing of sensor signals, the realization of the filtering algorithm, motion control and human-computer interaction. Produced and debugging in the whole system is completed, the car can realize the independent balance under the condition of no intervention. The introduction of a suitable amount of interference, the car can adjust quickly to recover and steady state. Through remote control car bluetooth module complete forward, backward, turn left and other basic action..
Scene-based nonuniformity correction for airborne point target detection systems.
Zhou, Dabiao; Wang, Dejiang; Huo, Lijun; Liu, Rang; Jia, Ping
2017-06-26
Images acquired by airborne infrared search and track (IRST) systems are often characterized by nonuniform noise. In this paper, a scene-based nonuniformity correction method for infrared focal-plane arrays (FPAs) is proposed based on the constant statistics of the received radiation ratios of adjacent pixels. The gain of each pixel is computed recursively based on the ratios between adjacent pixels, which are estimated through a median operation. Then, an elaborate mathematical model describing the error propagation, derived from random noise and the recursive calculation procedure, is established. The proposed method maintains the characteristics of traditional methods in calibrating the whole electro-optics chain, in compensating for temporal drifts, and in not preserving the radiometric accuracy of the system. Moreover, the proposed method is robust since the frame number is the only variant, and is suitable for real-time applications owing to its low computational complexity and simplicity of implementation. The experimental results, on different scenes from a proof-of-concept point target detection system with a long-wave Sofradir FPA, demonstrate the compelling performance of the proposed method.
Pulsar Timing and Its Application for Navigation and Gravitational Wave Detection
NASA Astrophysics Data System (ADS)
Becker, Werner; Kramer, Michael; Sesana, Alberto
2018-02-01
Pulsars are natural cosmic clocks. On long timescales they rival the precision of terrestrial atomic clocks. Using a technique called pulsar timing, the exact measurement of pulse arrival times allows a number of applications, ranging from testing theories of gravity to detecting gravitational waves. Also an external reference system suitable for autonomous space navigation can be defined by pulsars, using them as natural navigation beacons, not unlike the use of GPS satellites for navigation on Earth. By comparing pulse arrival times measured on-board a spacecraft with predicted pulse arrivals at a reference location (e.g. the solar system barycenter), the spacecraft position can be determined autonomously and with high accuracy everywhere in the solar system and beyond. We describe the unique properties of pulsars that suggest that such a navigation system will certainly have its application in future astronautics. We also describe the on-going experiments to use the clock-like nature of pulsars to "construct" a galactic-sized gravitational wave detector for low-frequency (f_{GW}˜ 10^{-9} - 10^{-7} Hz) gravitational waves. We present the current status and provide an outlook for the future.
Remote and in situ sensing products in chemical reaction using a flexible terahertz pipe waveguide.
You, Borwen; Lu, Ja-Yu
2016-08-08
The feasibility of remote chemical detection is experimentally demonstrated by using a Teflon pipe as a scanning arm in a continuous-terahertz wave sensing and imaging system. Different tablets with distinct mixed ratios of aluminum and polyethylene powders are well distinguished by measuring the power reflectivities of 0.4 THz wave associated with their distinct terahertz refractive indices. Given its refractive index sensitivity and fast response, the reflective terahertz sensing system can be used to real-time trace and quantitatively analyze the ammonium-chloride aerosols produced by the chemical reaction between hydrochloric acid and ammonia vapors. With a tightly focusing terahertz beam spot, the spatial and concentration distributions of the generated chemical product are successfully mapped out by the 1D scan of the flexible pipe probe. In consideration of the responsitivity, power stability, and focused spot size of the system, its detection limit for the ammonium-chloride aerosol is estimated to be approximately 165 nmol/mm2. The reliable and compact terahertz pipe scan system is potentially suitable for practical applications, such as biomedical or industrial fiber endoscopy.
Christiansen, Peter; Nielsen, Lars N; Steen, Kim A; Jørgensen, Rasmus N; Karstoft, Henrik
2016-11-11
Convolutional neural network (CNN)-based systems are increasingly used in autonomous vehicles for detecting obstacles. CNN-based object detection and per-pixel classification (semantic segmentation) algorithms are trained for detecting and classifying a predefined set of object types. These algorithms have difficulties in detecting distant and heavily occluded objects and are, by definition, not capable of detecting unknown object types or unusual scenarios. The visual characteristics of an agriculture field is homogeneous, and obstacles, like people, animals and other obstacles, occur rarely and are of distinct appearance compared to the field. This paper introduces DeepAnomaly, an algorithm combining deep learning and anomaly detection to exploit the homogenous characteristics of a field to perform anomaly detection. We demonstrate DeepAnomaly as a fast state-of-the-art detector for obstacles that are distant, heavily occluded and unknown. DeepAnomaly is compared to state-of-the-art obstacle detectors including "Faster R-CNN: Towards Real-Time Object Detection with Region Proposal Networks" (RCNN). In a human detector test case, we demonstrate that DeepAnomaly detects humans at longer ranges (45-90 m) than RCNN. RCNN has a similar performance at a short range (0-30 m). However, DeepAnomaly has much fewer model parameters and (182 ms/25 ms =) a 7.28-times faster processing time per image. Unlike most CNN-based methods, the high accuracy, the low computation time and the low memory footprint make it suitable for a real-time system running on a embedded GPU (Graphics Processing Unit).
Christiansen, Peter; Nielsen, Lars N.; Steen, Kim A.; Jørgensen, Rasmus N.; Karstoft, Henrik
2016-01-01
Convolutional neural network (CNN)-based systems are increasingly used in autonomous vehicles for detecting obstacles. CNN-based object detection and per-pixel classification (semantic segmentation) algorithms are trained for detecting and classifying a predefined set of object types. These algorithms have difficulties in detecting distant and heavily occluded objects and are, by definition, not capable of detecting unknown object types or unusual scenarios. The visual characteristics of an agriculture field is homogeneous, and obstacles, like people, animals and other obstacles, occur rarely and are of distinct appearance compared to the field. This paper introduces DeepAnomaly, an algorithm combining deep learning and anomaly detection to exploit the homogenous characteristics of a field to perform anomaly detection. We demonstrate DeepAnomaly as a fast state-of-the-art detector for obstacles that are distant, heavily occluded and unknown. DeepAnomaly is compared to state-of-the-art obstacle detectors including “Faster R-CNN: Towards Real-Time Object Detection with Region Proposal Networks” (RCNN). In a human detector test case, we demonstrate that DeepAnomaly detects humans at longer ranges (45–90 m) than RCNN. RCNN has a similar performance at a short range (0–30 m). However, DeepAnomaly has much fewer model parameters and (182 ms/25 ms =) a 7.28-times faster processing time per image. Unlike most CNN-based methods, the high accuracy, the low computation time and the low memory footprint make it suitable for a real-time system running on a embedded GPU (Graphics Processing Unit). PMID:27845717
Gillham, Michael; Howells, Gareth; Spurgeon, Sarah; McElroy, Ben
2013-01-01
Assistive robotic applications require systems capable of interaction in the human world, a workspace which is highly dynamic and not always predictable. Mobile assistive devices face the additional and complex problem of when and if intervention should occur; therefore before any trajectory assistance is given, the robotic device must know where it is in real-time, without unnecessary disruption or delay to the user requirements. In this paper, we demonstrate a novel robust method for determining room identification from floor features in a real-time computational frame for autonomous and assistive robotics in the human environment. We utilize two inexpensive sensors: an optical mouse sensor for straightforward and rapid, texture or pattern sampling, and a four color photodiode light sensor for fast color determination. We show how data relating floor texture and color obtained from typical dynamic human environments, using these two sensors, compares favorably with data obtained from a standard webcam. We show that suitable data can be extracted from these two sensors at a rate 16 times faster than a standard webcam, and that these data are in a form which can be rapidly processed using readily available classification techniques, suitable for real-time system application. We achieved a 95% correct classification accuracy identifying 133 rooms' flooring from 35 classes, suitable for fast coarse global room localization application, boundary crossing detection, and additionally some degree of surface type identification. PMID:24351647
Gillham, Michael; Howells, Gareth; Spurgeon, Sarah; McElroy, Ben
2013-12-17
Assistive robotic applications require systems capable of interaction in the human world, a workspace which is highly dynamic and not always predictable. Mobile assistive devices face the additional and complex problem of when and if intervention should occur; therefore before any trajectory assistance is given, the robotic device must know where it is in real-time, without unnecessary disruption or delay to the user requirements. In this paper, we demonstrate a novel robust method for determining room identification from floor features in a real-time computational frame for autonomous and assistive robotics in the human environment. We utilize two inexpensive sensors: an optical mouse sensor for straightforward and rapid, texture or pattern sampling, and a four color photodiode light sensor for fast color determination. We show how data relating floor texture and color obtained from typical dynamic human environments, using these two sensors, compares favorably with data obtained from a standard webcam. We show that suitable data can be extracted from these two sensors at a rate 16 times faster than a standard webcam, and that these data are in a form which can be rapidly processed using readily available classification techniques, suitable for real-time system application. We achieved a 95% correct classification accuracy identifying 133 rooms' flooring from 35 classes, suitable for fast coarse global room localization application, boundary crossing detection, and additionally some degree of surface type identification.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hentschke, Clemens M., E-mail: clemens.hentschke@gmail.com; Tönnies, Klaus D.; Beuing, Oliver
Purpose: The early detection of cerebral aneurysms plays a major role in preventing subarachnoid hemorrhage. The authors present a system to automatically detect cerebral aneurysms in multimodal 3D angiographic data sets. The authors’ system is parametrizable for contrast-enhanced magnetic resonance angiography (CE-MRA), time-of-flight magnetic resonance angiography (TOF-MRA), and computed tomography angiography (CTA). Methods: Initial volumes of interest are found by applying a multiscale sphere-enhancing filter. Several features are combined in a linear discriminant function (LDF) to distinguish between true aneurysms and false positives. The features include shape information, spatial information, and probability information. The LDF can either be parametrized bymore » domain experts or automatically by training. Vessel segmentation is avoided as it could heavily influence the detection algorithm. Results: The authors tested their method with 151 clinical angiographic data sets containing 112 aneurysms. The authors reach a sensitivity of 95% with CE-MRA data sets at an average false positive rate per data set (FP{sub DS}) of 8.2. For TOF-MRA, we achieve 95% sensitivity at 11.3 FP{sub DS}. For CTA, we reach a sensitivity of 95% at 22.8 FP{sub DS}. For all modalities, the expert parametrization led to similar or better results than the trained parametrization eliminating the need for training. 93% of aneurysms that were smaller than 5 mm were found. The authors also showed that their algorithm is capable of detecting aneurysms that were previously overlooked by radiologists. Conclusions: The authors present an automatic system to detect cerebral aneurysms in multimodal angiographic data sets. The system proved as a suitable computer-aided detection tool to help radiologists find cerebral aneurysms.« less
Artificial selection for food colour preferences.
Cole, Gemma L; Endler, John A
2015-04-07
Colour is an important factor in food detection and acquisition by animals using visually based foraging. Colour can be used to identify the suitability of a food source or improve the efficiency of food detection, and can even be linked to mate choice. Food colour preferences are known to exist, but whether these preferences are heritable and how these preferences evolve is unknown. Using the freshwater fish Poecilia reticulata, we artificially selected for chase behaviour towards two different-coloured moving stimuli: red and blue spots. A response to selection was only seen for chase behaviours towards the red, with realized heritabilities ranging from 0.25 to 0.30. Despite intense selection, no significant chase response was recorded for the blue-selected lines. This lack of response may be due to the motion-detection mechanism in the guppy visual system and may have novel implications for the evolvability of responses to colour-related signals. The behavioural response to several colours after five generations of selection suggests that the colour opponency system of the fish may regulate the response to selection. © 2015 The Author(s) Published by the Royal Society. All rights reserved.
A pH-based biosensor for detection of arsenic in drinking water.
de Mora, K; Joshi, N; Balint, B L; Ward, F B; Elfick, A; French, C E
2011-05-01
Arsenic contaminated groundwater is estimated to affect over 100 million people worldwide, with Bangladesh and West Bengal being among the worst affected regions. A simple, cheap, accurate and disposable device is required for arsenic field testing. We have previously described a novel biosensor for arsenic in which the output is a change in pH, which can be detected visually as a colour change by the use of a pH indicator. Here, we present an improved formulation allowing sensitive and accurate detection of less than 10 ppb arsenate with static overnight incubation. Furthermore, we describe a cheap and simple high-throughput system for simultaneous monitoring of pH in multiple assays over time. Up to 50 samples can be monitored continuously over the desired time period. Cells can be stored and distributed in either air-dried or freeze-dried form. This system was successfully tested on arsenic-contaminated groundwater samples from the South East region of Hungary. We hope to continue to develop this sensor to produce a device suitable for field trials.
DeWitt, Jamie C; Peden-Adams, Margie M; Keil, Deborah E; Dietert, Rodney R
2012-02-01
Developmental immunotoxicity (DIT) occurs when exposure to environmental risk factors prior to adulthood, including chemical, biological, physical, or physiological factors, alters immune system development. DIT may elicit suppression, hyperactivation, or misregulation of immune responses and may present clinically as decreased resistance to pathogens, allergic and autoimmune diseases, and inflammatory diseases. Immunotoxicity testing guidelines established by the Environmental Protection Agency for adult animals (OPPTS 8703.7800) require functional tests and immunophenotyping that are suitable for detecting immunomodulation, especially immunosuppression. However, evaluating immune function in offspring that are not fully immunocompetent yields results that are challenging to interpret. Therefore, this unit will describe an optimum exposure scenario, reference two assays (immunophenotyping and histopathology) appropriate for detecting immunomodulation in weaning-age offspring, and reference four assays (immunophenotyping, histopathology, T cell-dependent antibody responses, and delayed-type hypersensitivity) appropriate for detecting immunomodulation in immunocompetent offspring. The protocol also will reference other assays (natural killer cell and cytotoxic T lymphocyte) with potential utility for assessing DIT. © 2012 by John Wiley & Sons, Inc.
Steganalysis feature improvement using expectation maximization
NASA Astrophysics Data System (ADS)
Rodriguez, Benjamin M.; Peterson, Gilbert L.; Agaian, Sos S.
2007-04-01
Images and data files provide an excellent opportunity for concealing illegal or clandestine material. Currently, there are over 250 different tools which embed data into an image without causing noticeable changes to the image. From a forensics perspective, when a system is confiscated or an image of a system is generated the investigator needs a tool that can scan and accurately identify files suspected of containing malicious information. The identification process is termed the steganalysis problem which focuses on both blind identification, in which only normal images are available for training, and multi-class identification, in which both the clean and stego images at several embedding rates are available for training. In this paper an investigation of a clustering and classification technique (Expectation Maximization with mixture models) is used to determine if a digital image contains hidden information. The steganalysis problem is for both anomaly detection and multi-class detection. The various clusters represent clean images and stego images with between 1% and 10% embedding percentage. Based on the results it is concluded that the EM classification technique is highly suitable for both blind detection and the multi-class problem.
Study on road sign recognition in LabVIEW
NASA Astrophysics Data System (ADS)
Panoiu, M.; Rat, C. L.; Panoiu, C.
2016-02-01
Road and traffic sign identification is a field of study that can be used to aid the development of in-car advisory systems. It uses computer vision and artificial intelligence to extract the road signs from outdoor images acquired by a camera in uncontrolled lighting conditions where they may be occluded by other objects, or may suffer from problems such as color fading, disorientation, variations in shape and size, etc. An automatic means of identifying traffic signs, in these conditions, can make a significant contribution to develop an Intelligent Transport Systems (ITS) that continuously monitors the driver, the vehicle, and the road. Road and traffic signs are characterized by a number of features which make them recognizable from the environment. Road signs are located in standard positions and have standard shapes, standard colors, and known pictograms. These characteristics make them suitable for image identification. Traffic sign identification covers two problems: traffic sign detection and traffic sign recognition. Traffic sign detection is meant for the accurate localization of traffic signs in the image space, while traffic sign recognition handles the labeling of such detections into specific traffic sign types or subcategories [1].
Flexible surface acoustic wave respiration sensor for monitoring obstructive sleep apnea syndrome
NASA Astrophysics Data System (ADS)
Jin, Hao; Tao, Xiang; Dong, Shurong; Qin, Yiheng; Yu, Liyang; Luo, Jikui; Deen, M. Jamal
2017-11-01
Obstructive sleep apnea syndrome (OSAS) has received much attention in recent years due to its significant harm to human health and high morbidity rate. A respiration monitoring system is needed to detect OSAS, so that the patient can receive treatment in a timely manner. Wired and wireless OSAS monitoring systems have been developed, but they require a wire connection and batteries to operate, and they are bulky, heavy and not user-friendly. In this paper, we propose the use of a flexible surface acoustic wave (SAW) microsensor to detect and monitor OSAS by measuring the humidity change associated with the respiration of a person. SAW sensors on rigid 128° YX LiNbO3 substrate are also characterized for this application. Results show both types of SAW sensors are suitable for OSAS monitoring with good sensitivity, repeatability and reliability, and the response time and recovery time for the flexible SAW sensors are 1.125 and 0.75 s, respectively. Our work demonstrates the potential for an innovative flexible microsensor for the detection and monitoring of OSAS.
Artificial selection for food colour preferences
Cole, Gemma L.; Endler, John A.
2015-01-01
Colour is an important factor in food detection and acquisition by animals using visually based foraging. Colour can be used to identify the suitability of a food source or improve the efficiency of food detection, and can even be linked to mate choice. Food colour preferences are known to exist, but whether these preferences are heritable and how these preferences evolve is unknown. Using the freshwater fish Poecilia reticulata, we artificially selected for chase behaviour towards two different-coloured moving stimuli: red and blue spots. A response to selection was only seen for chase behaviours towards the red, with realized heritabilities ranging from 0.25 to 0.30. Despite intense selection, no significant chase response was recorded for the blue-selected lines. This lack of response may be due to the motion-detection mechanism in the guppy visual system and may have novel implications for the evolvability of responses to colour-related signals. The behavioural response to several colours after five generations of selection suggests that the colour opponency system of the fish may regulate the response to selection. PMID:25740894
Brito Palma, Bernardo; Fisher, Charles W; Rueff, José; Kranendonk, Michel
2016-05-16
The formation of reactive metabolites through biotransformation is the suspected cause of many adverse drug reactions. Testing for the propensity of a drug to form reactive metabolites has increasingly become an integral part of lead-optimization strategy in drug discovery. DNA reactivity is one undesirable facet of a drug or its metabolites and can lead to increased risk of cancer and reproductive toxicity. Many drugs are metabolized by cytochromes P450 in the liver and other tissues, and these reactions can generate hard electrophiles. These hard electrophilic reactive metabolites may react with DNA and may be detected in standard in vitro genotoxicity assays; however, the majority of these assays fall short due to the use of animal-derived organ extracts that inadequately represent human metabolism. The current study describes the development of bacterial systems that efficiently detect DNA-damaging electrophilic reactive metabolites generated by human P450 biotransformation. These assays use a GFP reporter system that detects DNA damage through induction of the SOS response and a GFP reporter to control for cytotoxicity. Two human CYP1A2-competent prototypes presented here have appropriate characteristics for the detection of DNA-damaging reactive metabolites in a high-throughput manner. The advantages of this approach include a short assay time (120-180 min) with real-time measurement, sensitivity to small amounts of compound, and adaptability to a microplate format. These systems are suitable for high-throughput assays and can serve as prototypes for the development of future enhanced versions.
Kumar Thakur, Rupak; Anoop, C S
2015-08-01
Cardio-vascular health monitoring has gained considerable attention in the recent years. Principle of non-contact capacitive electrocardiograph (ECG) and its applicability as a valuable, low-cost, easy-to-use scheme for cardio-vascular health monitoring has been demonstrated in some recent research papers. In this paper, we develop a complete non-contact ECG system using a suitable front-end electronic circuit and a heart-rate (HR) measurement unit using enhanced Fourier interpolation technique. The front-end electronic circuit is realized using low-cost, readily available components and the proposed HR measurement unit is designed to achieve fairly accurate results. The entire system has been extensively tested to verify its efficacy and test results show that the developed system can estimate HR with an accuracy of ±2 beats. Detailed tests have been conducted to validate the performance of the system for different cloth thicknesses of the subject. Some basic tests which illustrate the application of the proposed system for heart-rate variability estimation has been conducted and results reported. The developed system can be used as a portable, reliable, long-term cardiac health monitoring device and can be extended to human drowsiness detection.
Vibro-Perception of Optical Bio-Inspired Fiber-Skin.
Li, Tao; Zhang, Sheng; Lu, Guo-Wei; Sunami, Yuta
2018-05-12
In this research, based on the principle of optical interferometry, the Mach-Zehnder and Optical Phase-locked Loop (OPLL) vibro-perception systems of bio-inspired fiber-skin are designed to mimic the tactile perception of human skin. The fiber-skin is made of the optical fiber embedded in the silicone elastomer. The optical fiber is an instinctive and alternative sensor for tactile perception with high sensitivity and reliability, also low cost and susceptibility to the magnetic interference. The silicone elastomer serves as a substrate with high flexibility and biocompatibility, and the optical fiber core serves as the vibro-perception sensor to detect physical motions like tapping and sliding. According to the experimental results, the designed optical fiber-skin demonstrates the ability to detect the physical motions like tapping and sliding in both the Mach-Zehnder and OPLL vibro-perception systems. For direct contact condition, the OPLL vibro-perception system shows better performance compared with the Mach-Zehnder vibro-perception system. However, the Mach-Zehnder vibro-perception system is preferable to the OPLL system in the indirect contact experiment. In summary, the fiber-skin is validated to have light touch character and excellent repeatability, which is highly-suitable for skin-mimic sensing.
NASA Astrophysics Data System (ADS)
Bitner, Rex M.; Koller, Susan C.
2004-06-01
Three different methods of automated high throughput purification of genomic DNA from plant materials processed in 96 well plates are described. One method uses MagneSil paramagnetic particles to purify DNA present in single leaf punch samples or small seed samples, using 320ul capacity 96 well plates which minimizes reagent and plate costs. A second method uses 2.2 ml and 1.2 ml capacity plates and allows the purification of larger amounts of DNA from 5-6 punches of materials or larger amounts of seeds. The third method uses the MagneSil ONE purification system to purify a fixed amount of DNA, thus simplifying the processing of downstream applications by normalizing the amounts of DNA so they do not require quantitation. Protocols for the purification of a fixed yield of DNA, e.g. 1 ug, from plant leaf or seed samples using MagneSil paramagnetic particles and a Beckman-Coulter BioMek FX robot are described. DNA from all three methods is suitable for applications such as PCR, RAPD, STR, READIT SNP analysis, and multiplexed PCR systems. The MagneSil ONE system is also suitable for use with SNP detection systems such as Third Wave Technology"s Invader methods.
al-Wahish, Amal; Armitage, D; al-Binni, U; Hill, B; Mills, R; Jalarvo, N; Santodonato, L; Herwig, K W; Mandrus, D
2015-09-01
A design for a sample cell system suitable for high temperature Quasi-Elastic Neutron Scattering (QENS) experiments is presented. The apparatus was developed at the Spallation Neutron Source in Oak Ridge National Lab where it is currently in use. The design provides a special sample cell environment under controlled humid or dry gas flow over a wide range of temperature up to 950 °C. Using such a cell, chemical, dynamical, and physical changes can be studied in situ under various operating conditions. While the cell combined with portable automated gas environment system is especially useful for in situ studies of microscopic dynamics under operational conditions that are similar to those of solid oxide fuel cells, it can additionally be used to study a wide variety of materials, such as high temperature proton conductors. The cell can also be used in many different neutron experiments when a suitable sample holder material is selected. The sample cell system has recently been used to reveal fast dynamic processes in quasi-elastic neutron scattering experiments, which standard probes (such as electrochemical impedance spectroscopy) could not detect. In this work, we outline the design of the sample cell system and present results demonstrating its abilities in high temperature QENS experiments.
NASA Astrophysics Data System (ADS)
Alam, M. Z.; Moreno, J.; Aitchison, J. S.; Mojahedi, M.; Kazemi, A. A.
2008-08-01
Launch vehicles and other satellite users need launch services that are highly reliable, less complex, easier to test, and cost effective. Being a very small molecule, hydrogen is prone to leakage through seals and micro-cracks. Hydrogen detection in space application is very challenging; public acceptance of hydrogen fuel would require the integration of a reliable hydrogen safety sensor. For detecting leakage of cryogenic fluids in spaceport facilities, launch vehicle industry and aerospace agencies are currently relying heavily on the bulky mass spectrometers, which fill one or more equipment racks, and weigh several hundred kilograms. Therefore, there is a critical need for miniaturized sensors and instruments suitable for use in space applications. This paper describes a novel multi-channel integrated nano-engineered optical sensor to detect hydrogen and monitor the temperature. The integrated optic sensor is made of multi-channel waveguide elements that measure hydrogen concentration in real Time. Our sensor is based on the use of a high index waveguide with a Ni/Pd overlay to detect hydrogen. When hydrogen is absorbed into the Ni/Pd alloy there is a change in the absorption of the material and the optical signal in the waveguide is increased. Our design uses a thin alloy (few nanometers thick) overlay which facilitates the absorption of the hydrogen and will result in a response time of approximately few seconds. Like other Pd/Pd-Ni based sensors the device response varies with temperature and hence the effects of temperature variations must be taken into account. One solution to this problem is simultaneous measurement of temperature in addition to hydrogen concentration at the same vicinity. Our approach here is to propose a temperature sensor that can easily be integrated on the same platform as the hydrogen sensor reported earlier by our group. One suitable choice of material system is silicon on insulator (SOI). Here, we propose a micro ring resonators (MRR) based temperature sensor designed on SOI that measures temperature by monitoring the output optical power.
Borkowski, C J
1954-01-19
This pulse-type survey instrument is suitable for readily detecting {alpha} particles in the presence of high {beta} and {gamma} backgrounds. The instruments may also be used to survey for neutrons, {beta} particles and {gamma} rays by employing suitably designed interchangeable probes and selecting an operating potential to correspond to the particular probe.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Demos, S G; Gandour-Edwards, R; Ramsamooj, R
The feasibility of developing bladder cancer detection methods using intrinsic tissue optical properties is the focus of this investigation. In vitro experiments have been performed using polarized elastic light scattering in combination with tissue autofluorescence in the NIR spectral region under laser excitation in the green and red spectral regions. The experimental results obtained from a set of tissue specimens from 25 patients reveal the presence of optical fingerprint characteristics suitable for cancer detection with high contrast and accuracy. These photonic methods are compatible with existing endoscopic imaging modalities which make them suitable for in-vivo application.
NASA Astrophysics Data System (ADS)
Ye, Jian; Liu, Guanghui; Liu, Peng; Zhang, Shiwu; Shao, Pengfei; Smith, Zachary J.; Liu, Chenhai; Xu, Ronald X.
2018-02-01
We propose a portable fluorescence microscopic imaging system (PFMS) for intraoperative display of biliary structure and prevention of iatrogenic injuries during cholecystectomy. The system consists of a light source module, a camera module, and a Raspberry Pi computer with an LCD. Indocyanine green (ICG) is used as a fluorescent contrast agent for experimental validation of the system. Fluorescence intensities of the ICG aqueous solution at different concentration levels are acquired by our PFMS and compared with those of a commercial Xenogen IVIS system. We study the fluorescence detection depth by superposing different thicknesses of chicken breast on an ICG-loaded agar phantom. We verify the technical feasibility for identifying potential iatrogenic injury in cholecystectomy using a rat model in vivo. The proposed PFMS system is portable, inexpensive, and suitable for deployment in resource-limited settings.
Fixation of virgin lunar surface soil
NASA Technical Reports Server (NTRS)
Conley, J. M.; Frazer, R.; Cannon, W. A.
1972-01-01
Two systems are shown to be suitable for fixing loose particulate soils with a polymer film, without visually detectable disturbance of the soil particle spatial relationships. A two-component system is described, which uses a gas monomer condensible at the soil temperature and a gas phase catalyst acting to polymerize the monomer. A one-component system using a monomer which polymerizes spontaneously on and within the top few millimeters of the soil is also considered. The two-component system employs a simpler apparatus, but it operates over a narrower temperature range (approximately -40 to -10 C). Other two-component systems were identified which may operate at soil temperatures as high as +100 C, at relatively narrow temperature ranges of approximately 30 C. The one-component system was demonstrated to operate successfully with initial soil temperatures from -70 C or lower to +150 C.
10 CFR 963.16 - Postclosure suitability evaluation method.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 4 2014-01-01 2014-01-01 false Postclosure suitability evaluation method. 963.16 Section... Determination, Methods, and Criteria § 963.16 Postclosure suitability evaluation method. (a) DOE will evaluate postclosure suitability using the total system performance assessment method. DOE will conduct a total system...
10 CFR 963.16 - Postclosure suitability evaluation method.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 4 2011-01-01 2011-01-01 false Postclosure suitability evaluation method. 963.16 Section... Determination, Methods, and Criteria § 963.16 Postclosure suitability evaluation method. (a) DOE will evaluate postclosure suitability using the total system performance assessment method. DOE will conduct a total system...
10 CFR 963.16 - Postclosure suitability evaluation method.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 4 2012-01-01 2012-01-01 false Postclosure suitability evaluation method. 963.16 Section... Determination, Methods, and Criteria § 963.16 Postclosure suitability evaluation method. (a) DOE will evaluate postclosure suitability using the total system performance assessment method. DOE will conduct a total system...
A Method for Harmonic Sources Detection based on Harmonic Distortion Power Rate
NASA Astrophysics Data System (ADS)
Lin, Ruixing; Xu, Lin; Zheng, Xian
2018-03-01
Harmonic sources detection at the point of common coupling is an essential step for harmonic contribution determination and harmonic mitigation. The harmonic distortion power rate index is proposed for harmonic source location based on IEEE Std 1459-2010 in the paper. The method only based on harmonic distortion power is not suitable when the background harmonic is large. To solve this problem, a threshold is determined by the prior information, when the harmonic distortion power is larger than the threshold, the customer side is considered as the main harmonic source, otherwise, the utility side is. A simple model of public power system was built in MATLAB/Simulink and field test results of typical harmonic loads verified the effectiveness of proposed method.
Active sampling technique to enhance chemical signature of buried explosives
NASA Astrophysics Data System (ADS)
Lovell, John S.; French, Patrick D.
2004-09-01
Deminers and dismounted countermine engineers commonly use metal detectors, ground penetrating radar and probes to locate mines. Many modern landmines have a very low metal content, which severely limits the effectiveness of metal detectors. Canines have also been used for landmine detection for decades. Experiments have shown that canines smell the explosives which are known to leak from most types of landmines. The fact that dogs can detect landmines indicates that vapor sensing is a viable approach to landmine detection. Several groups are currently developing systems to detect landmines by "sniffing" for the ultra-trace explosive vapors above the soil. The amount of material that is available to passive vapor sensing systems is limited to no more than the vapor in equilibrium with the explosive related chemicals (ERCs) distributed in the surface soils over and near the landmine. The low equilibrium vapor pressure of TNT in the soil/atmosphere boundary layer and the limited volume of the boundary layer air imply that passive chemical vapor sensing systems require sensitivities in the picogram range, or lower. ADA is working to overcome many of the limitations of passive sampling methods, by the use of an active sampling method that employs a high-powered (1,200+ joules) strobe lamp to create a highly amplified plume of vapor and/or ERC-bearing fine particulates. Initial investigations have demonstrated that this approach can amplify the detectability of TNT by two or three orders of magnitude. This new active sampling technique could be used with any suitable explosive sensor.
Lung boundary detection in pediatric chest x-rays
NASA Astrophysics Data System (ADS)
Candemir, Sema; Antani, Sameer; Jaeger, Stefan; Browning, Renee; Thoma, George R.
2015-03-01
Tuberculosis (TB) is a major public health problem worldwide, and highly prevalent in developing countries. According to the World Health Organization (WHO), over 95% of TB deaths occur in low- and middle- income countries that often have under-resourced health care systems. In an effort to aid population screening in such resource challenged settings, the U.S. National Library of Medicine has developed a chest X-ray (CXR) screening system that provides a pre-decision on pulmonary abnormalities. When the system is presented with a digital CXR image from the Picture Archive and Communication Systems (PACS) or an imaging source, it automatically identifies the lung regions in the image, extracts image features, and classifies the image as normal or abnormal using trained machine-learning algorithms. The system has been trained on adult CXR images, and this article presents enhancements toward including pediatric CXR images. Our adult lung boundary detection algorithm is model-based. We note the lung shape differences during pediatric developmental stages, and adulthood, and propose building new lung models suitable for pediatric developmental stages. In this study, we quantify changes in lung shape from infancy to adulthood toward enhancing our lung segmentation algorithm. Our initial findings suggest pediatric age groupings of 0 - 23 months, 2 - 10 years, and 11 - 18 years. We present justification for our groupings. We report on the quality of boundary detection algorithm with the pediatric lung models.
ATimer-Actuated, Immunoassay Cassette for Detecting Molecular Markers in Oral Fluids
Liu, Changchun; Qiu, Xianbo; Ongagna, Serge; Chen, Dafeng; Chen, Zongyuan; Abrams, William R.; Malamud, Daniel; Corstjens, Paul L.A.M.; Bau, Haim H.
2009-01-01
An inexpensive, hand-held, point-of-care, disposable, self-contained, immunoassay cassette comprised of air pouches for pumping, a metering chamber, reagents storage chambers, a mixer, and a lateral flow strip was designed, constructed, and tested. The assay was carried out in a consecutive flow format. The detection was facilitated with up-converting, phosphor (UCP) reporter particles. The automated, timely pumping of the various reagents was driven by a spring-loaded timer. The utility of the cassette was demonstrated by detecting antibodies to HIV in saliva samples and further evaluated with a non-contagious, haptenized DNA assay. The cassette has several advantages over dip sticks such as sample preprocessing, integrated storage of reagents, and automated operation that reduces operator errors and training. The cassette and actuator described herein can readily be extended to detect biomarkers of other diseases in body fluids and other fluids at the point of care. The system is particularly suitable for resource poor countries, where funds and trained personnel are in short supply. PMID:19255658
Illicit drug detection with laser 1: investigation of optimal parameters in stomach tissue
NASA Astrophysics Data System (ADS)
Özer, Ayşen Gürkan; Tabakoğlu, Haşim Özgür; Cengiz, Salih
2014-05-01
The main purpose of this study is to establish radiation-safe scanning of passersby at high security areas, such as airports and customs. The stomach was selected as the organ to be analyzed. In order to determine whether a substance found inside a human body as wrapped in a plastic bag is filled narcotics or not, many substances in white powder form including morphine-HCL were inspected. Inspection was carried out with on-ionizing radiation by irradiating stomach tissue with laser light. Optical transmittance of lamb stomach tissue was analyzed at different wavelengths. We showed that detection by 650-nm diode laser irradiation would be suitable for such a radiation-safe scan. Different materials were also investigated for absorptive properties, and closed system Raman studies were performed. The spectrum of a molecule found inside white powder placed behind the lamb stomach tissue was detected as a fingerprint. This allowed the detection of target substances without any physical contact or damage to the biological tissue.
Digitally balanced detection for optical tomography.
Hafiz, Rehan; Ozanyan, Krikor B
2007-10-01
Analog balanced Photodetection has found extensive usage for sensing of a weak absorption signal buried in laser intensity noise. This paper proposes schemes for compact, affordable, and flexible digital implementation of the already established analog balanced detection, as part of a multichannel digital tomography system. Variants of digitally balanced detection (DBD) schemes, suitable for weak signals on a largely varying background or weakly varying envelopes of high frequency carrier waves, are introduced analytically and elaborated in terms of algorithmic and hardware flow. The DBD algorithms are implemented on a low-cost general purpose reconfigurable hardware (field-programmable gate array), utilizing less than half of its resources. The performance of the DBD schemes compare favorably with their analog counterpart: A common mode rejection ratio of 50 dB was observed over a bandwidth of 300 kHz, limited mainly by the host digital hardware. The close relationship between the DBD outputs and those of known analog balancing circuits is discussed in principle and shown experimentally in the example case of propane gas detection.
Novel Wearable Device for Blood Leakage Detection during Hemodialysis Using an Array Sensing Patch.
Du, Yi-Chun; Lim, Bee-Yen; Ciou, Wei-Siang; Wu, Ming-Jui
2016-06-09
Hemodialysis (HD) is a clinical treatment that requires the puncturing of the body surface. However, needle dislodgement can cause a high risk of blood leakage and can be fatal to patients. Previous studies proposed several devices for blood leakage detection using optical or electrical techniques. Nonetheless, these methods used single-point detection and the design was not suitable for multi-bed monitoring. This study proposed a novel wearable device for blood leakage monitoring during HD using an array sensing patch. The array sensing patch combined with a mapping circuit and a wireless module could measure and transmit risk levels. The different risk levels could improve the working process of healthcare workers, and enhance their work efficiency and reduce inconvenience due to false alarms. Experimental results showed that each point of the sensing array could detect up to 0.1 mL of blood leakage and the array sensing patch supports a risk level monitoring system up to 8 h to alert healthcare personnel of pertinent danger to the patients.
Adaptive waveform optimization design for target detection in cognitive radar
NASA Astrophysics Data System (ADS)
Zhang, Xiaowen; Wang, Kaizhi; Liu, Xingzhao
2017-01-01
The problem of adaptive waveform design for target detection in cognitive radar (CR) is investigated. This problem is analyzed in signal-dependent interference, as well as additive channel noise for extended target with unknown target impulse response (TIR). In order to estimate the TIR accurately, the Kalman filter is used in target tracking. In each Kalman filtering iteration, a flexible online waveform spectrum optimization design taking both detection and range resolution into account is modeled in Fourier domain. Unlike existing CR waveform, the proposed waveform can be simultaneously updated according to the environment information fed back by receiver and radar performance demands. Moreover, the influence of waveform spectral phase to radar performance is analyzed. Simulation results demonstrate that CR with the proposed waveform performs better than a traditional radar system with a fixed waveform and offers more flexibility and suitability. In addition, waveform spectral phase will not influence tracking, detection, and range resolution performance but will greatly influence waveform forming speed and peak-to-average power ratio.
Turkec, Aydin; Lucas, Stuart J; Karacanli, Burçin; Baykut, Aykut; Yuksel, Hakki
2016-03-01
Detection of GMO material in crop and food samples is the primary step in GMO monitoring and regulation, with the increasing number of GM events in the world market requiring detection solutions with high multiplexing capacity. In this study, we test the suitability of a high-density oligonucleotide microarray platform for direct, quantitative detection of GMOs found in the Turkish feed market. We tested 1830 different 60nt probes designed to cover the GM cassettes from 12 different GM cultivars (3 soya, 9 maize), as well as plant species-specific and contamination controls, and developed a data analysis method aiming to provide maximum throughput and sensitivity. The system was able specifically to identify each cultivar, and in 10/12 cases was sensitive enough to detect GMO DNA at concentrations of ⩽1%. These GMOs could also be quantified using the microarray, as their fluorescence signals increased linearly with GMO concentration. Copyright © 2015 Elsevier Ltd. All rights reserved.
A vision-based fall detection algorithm of human in indoor environment
NASA Astrophysics Data System (ADS)
Liu, Hao; Guo, Yongcai
2017-02-01
Elderly care becomes more and more prominent in China as the population is aging fast and the number of aging population is large. Falls, as one of the biggest challenges in elderly guardianship system, have a serious impact on both physical health and mental health of the aged. Based on feature descriptors, such as aspect ratio of human silhouette, velocity of mass center, moving distance of head and angle of the ultimate posture, a novel vision-based fall detection method was proposed in this paper. A fast median method of background modeling with three frames was also suggested. Compared with the conventional bounding box and ellipse method, the novel fall detection technique is not only applicable for recognizing the fall behaviors end of lying down but also suitable for detecting the fall behaviors end of kneeling down and sitting down. In addition, numerous experiment results showed that the method had a good performance in recognition accuracy on the premise of not adding the cost of time.
Christensen, Christian Bech; Christensen-Dalsgaard, Jakob; Madsen, Peter Teglberg
2015-02-01
In the transition from an aquatic to a terrestrial lifestyle, vertebrate auditory systems have undergone major changes while adapting to aerial hearing. Lungfish are the closest living relatives of tetrapods and their auditory system may therefore be a suitable model of the auditory systems of early tetrapods such as Acanthostega. Therefore, experimental studies on the hearing capabilities of lungfish may shed light on the possible hearing capabilities of early tetrapods and broaden our understanding of hearing across the water-to-land transition. Here, we tested the hypotheses that (i) lungfish are sensitive to underwater pressure using their lungs as pressure-to-particle motion transducers and (ii) lungfish can detect airborne sound. To do so, we used neurophysiological recordings to estimate the vibration and pressure sensitivity of African lungfish (Protopterus annectens) in both water and air. We show that lungfish detect underwater sound pressure via pressure-to-particle motion transduction by air volumes in their lungs. The morphology of lungfish shows no specialized connection between these air volumes and the inner ears, and so our results imply that air breathing may have enabled rudimentary pressure detection as early as the Devonian era. Additionally, we demonstrate that lungfish in spite of their atympanic middle ear can detect airborne sound through detection of sound-induced head vibrations. This strongly suggests that even vertebrates with no middle ear adaptations for aerial hearing, such as the first tetrapods, had rudimentary aerial hearing that may have led to the evolution of tympanic middle ears in recent tetrapods. © 2015. Published by The Company of Biologists Ltd.
NASA Astrophysics Data System (ADS)
Zheng, Yibo; Zhang, Lei; Wang, Yuan
2017-10-01
In this letter, surface plasmon resonance sensors based on grapefruit-type photonic crystal fiber (PCF)with different silver nano-filling structure have been analyzed and compared though the finite element method (FEM). The regularity of the resonant wavelength changing with refractive index of the sample has been numerically simulated. The surface plasmon resonance (SPR) sensing properties have been numerically simulated in both areas of resonant wavelength and intensity detection. Numerical results show that excellent sensor resolution of 4.17×10-5RIU can be achieved as the radius of the filling silver nanowires is 150 nm by spectrum detection method. Comprehensive comparison indicates that the 150 nm silver wire filling structure is suitable for spectrum detection and 30 nm silver film coating structure is suitable for the amplitude detection.
Pau, Chou-Pong; Wells, Susan K; Granade, Timothy C
2012-01-01
This chapter describes a real-time PCR method for the detection of HIV-1 proviral DNA in whole blood samples using a novel double-stranded primer system. The assay utilizes a simple commercially available DNA extraction method and a rapid and easy-to-perform real-time PCR protocol to consistently detect a minimum of four copies of HIV-1 group M proviral DNA in as little as 90 min after sample (whole blood) collection. Co-amplification of the human RNase P gene serves as an internal control to monitor the efficiency of both the DNA extraction and amplification. Once the assay is validated properly, it may be suitable as an alternative confirmation test for HIV-1 infections in a variety of HIV testing venues including the mother-to-child transmission testing sites, clinics, and diagnostic testing centers.
3D Printing and Assay Development for Point-of-Care Applications
NASA Astrophysics Data System (ADS)
Jagadeesh, Shreesha
Existing centralized labs do not serve patients adequately in remote areas. To enable universal timely healthcare, there is a need to develop low cost, portable systems that can diagnose multiple disease (Point-of-Care (POC) devices). Future POC diagnostics can be more multi-functional if medical device vendors can develop interoperability standards. This thesis developed the following medical diagnostic modules: Plasma from 25 microl blood was extracted through a filter membrane to demonstrate a 3D printed sample preparation module. Sepsis biomarker, C - reactive protein, was quantified through adsorption on nylon beads to demonstrate bead-based assay suitable for 3D printed disposable cartridge module. Finally, a modular fluorescent detection kit was built using 3D printed parts to detect CD4 cells in a disposable cartridge from ChipCare Corp. Due to the modularity enabled by 3D printing technique, the developed units can be easily adapted to detect other diseases.
A Widely Applicable Silver Sol for TLC Detection with Rich and Stable SERS Features.
Zhu, Qingxia; Li, Hao; Lu, Feng; Chai, Yifeng; Yuan, Yongfang
2016-12-01
Thin-layer chromatography (TLC) coupled with surface-enhanced Raman spectroscopy (SERS) has gained tremendous popularity in the study of various complex systems. However, the detection of hydrophobic analytes is difficult, and the specificity still needs to be improved. In this study, a SERS-active non-aqueous silver sol which could activate the analytes to produce rich and stable spectral features was rapidly synthesized. Then, the optimized silver nanoparticles (AgNPs)-DMF sol was employed for TLC-SERS detection of hydrophobic (and also hydrophilic) analytes. SERS performance of this sol was superior to that of traditional Lee-Meisel AgNPs due to its high specificity, acceptable stability, and wide applicability. The non-aqueous AgNPs would be suitable for the TLC-SERS method, which shows great promise for applications in food safety assurance, environmental monitoring, medical diagnoses, and many other fields.
A Widely Applicable Silver Sol for TLC Detection with Rich and Stable SERS Features
NASA Astrophysics Data System (ADS)
Zhu, Qingxia; Li, Hao; Lu, Feng; Chai, Yifeng; Yuan, Yongfang
2016-04-01
Thin-layer chromatography (TLC) coupled with surface-enhanced Raman spectroscopy (SERS) has gained tremendous popularity in the study of various complex systems. However, the detection of hydrophobic analytes is difficult, and the specificity still needs to be improved. In this study, a SERS-active non-aqueous silver sol which could activate the analytes to produce rich and stable spectral features was rapidly synthesized. Then, the optimized silver nanoparticles (AgNPs)-DMF sol was employed for TLC-SERS detection of hydrophobic (and also hydrophilic) analytes. SERS performance of this sol was superior to that of traditional Lee-Meisel AgNPs due to its high specificity, acceptable stability, and wide applicability. The non-aqueous AgNPs would be suitable for the TLC-SERS method, which shows great promise for applications in food safety assurance, environmental monitoring, medical diagnoses, and many other fields.
Increasing the efficiency of photon collection in LArTPCs: the ARAPUCA light trap
NASA Astrophysics Data System (ADS)
Cancelo, G.; Cavanna, F.; Escobar, C. O.; Kemp, E.; Machado, A. A.; Para, A.; Segreto, E.; Totani, D.; Warner, D.
2018-03-01
The Liquid Argon Time Projection Chambers (LArTPCs) are a choice for the next generation of large neutrino detectors due to their optimal performance in particle tracking and calorimetry. The detection of Argon scintillation light plays a crucial role in the event reconstruction as well as the time reference for non-beam physics such as supernovae neutrino detection and baryon number violation studies. In this contribution, we present the current R&D work on the ARAPUCA (Argon R&D Advanced Program at UNICAMP), a light trap device to enhance Ar scintillation light collection and thus the overall performance of LArTPCs. The ARAPUCA working principle is based on a suitable combination of dichroic filters and wavelength shifters to achieve a high efficiency in light collection. We discuss the operational principles, the last results of laboratory tests and the application of the ARAPUCA as the alternative photon detection system in the protoDUNE detector.
Analysis of Technology for Compact Coherent Lidar
NASA Technical Reports Server (NTRS)
Amzajerdian, Farzin
1997-01-01
In view of the recent advances in the area of solid state and semiconductor lasers has created new possibilities for the development of compact and reliable coherent lidars for a wide range of applications. These applications include: Automated Rendezvous and Capture, wind shear and clear air turbulence detection, aircraft wake vortex detection, and automobile collision avoidance. The work performed by the UAH personnel under this Delivery Order, concentrated on design and analyses of a compact coherent lidar system capable of measuring range and velocity of hard targets, and providing air mass velocity data. The following is the scope of this work. a. Investigate various laser sources and optical signal detection configurations in support of a compact and lightweight coherent laser radar to be developed for precision range and velocity measurements of hard and fuzzy targets. Through interaction with MSFC engineers, the most suitable laser source and signal detection technique that can provide a reliable compact and lightweight laser radar design will be selected. b. Analyze and specify the coherent laser radar system configuration and assist with its optical and electronic design efforts. Develop a system design including its optical layout design. Specify all optical components and provide the general requirements of the electronic subsystems including laser beam modulator and demodulator drivers, detector electronic interface, and the signal processor. c. Perform a thorough performance analysis to predict the system measurement range and accuracy. This analysis will utilize various coherent laser radar sensitivity formulations and different target models.
A Two-Stage Reconstruction Processor for Human Detection in Compressive Sensing CMOS Radar
Tsao, Kuei-Chi; Lee, Ling; Chu, Ta-Shun
2018-01-01
Complementary metal-oxide-semiconductor (CMOS) radar has recently gained much research attraction because small and low-power CMOS devices are very suitable for deploying sensing nodes in a low-power wireless sensing system. This study focuses on the signal processing of a wireless CMOS impulse radar system that can detect humans and objects in the home-care internet-of-things sensing system. The challenges of low-power CMOS radar systems are the weakness of human signals and the high computational complexity of the target detection algorithm. The compressive sensing-based detection algorithm can relax the computational costs by avoiding the utilization of matched filters and reducing the analog-to-digital converter bandwidth requirement. The orthogonal matching pursuit (OMP) is one of the popular signal reconstruction algorithms for compressive sensing radar; however, the complexity is still very high because the high resolution of human respiration leads to high-dimension signal reconstruction. Thus, this paper proposes a two-stage reconstruction algorithm for compressive sensing radar. The proposed algorithm not only has lower complexity than the OMP algorithm by 75% but also achieves better positioning performance than the OMP algorithm especially in noisy environments. This study also designed and implemented the algorithm by using Vertex-7 FPGA chip (Xilinx, San Jose, CA, USA). The proposed reconstruction processor can support the 256×13 real-time radar image display with a throughput of 28.2 frames per second. PMID:29621170
As a first step in a hierarchical scheme to demonstrate the suitability of present U.S. Environmental Protection Agency (USEPA) analysis methods and/or develop new methodology, the gas chromatographic (GC) separation and mass spectrometric (MS) detection characteristics of 328 to...
NASA Technical Reports Server (NTRS)
Natarajan, Suresh; Gardner, C. S.
1987-01-01
Receiver timing synchronization of an optical Pulse-Position Modulation (PPM) communication system can be achieved using a phased-locked loop (PLL), provided the photodetector output is suitably processed. The magnitude of the PLL phase error is a good indicator of the timing error at the receiver decoder. The statistics of the phase error are investigated while varying several key system parameters such as PPM order, signal and background strengths, and PPL bandwidth. A practical optical communication system utilizing a laser diode transmitter and an avalanche photodiode in the receiver is described, and the sampled phase error data are presented. A linear regression analysis is applied to the data to obtain estimates of the relational constants involving the phase error variance and incident signal power.
Hoffheins, B.S.; Lauf, R.J.
1997-08-05
A gas detecting system is described for classifying the type of liquid fuel in a container or tank. The system includes a plurality of semiconductor gas sensors, each of which differs from the other in its response to various organic vapors. The system includes a means of processing the responses of the plurality of sensors such that the responses to any particular organic substance or mixture is sufficiently distinctive to constitute a recognizable ``signature``. The signature of known substances are collected and divided into two classes based on some other known characteristic of the substances. A pattern recognition system classifies the signature of an unknown substance with reference to the two user-defined classes, thereby classifying the unknown substance with regard to the characteristic of interest, such as its suitability for a particular use. 14 figs.
Hoffheins, Barbara S.; Lauf, Robert J.
1997-01-01
A gas detecting system for classifying the type of liquid fuel in a container or tank. The system includes a plurality of semiconductor gas sensors, each of which differs from the other in its response to various organic vapors. The system includes a means of processing the responses of the plurality of sensors such that the responses to any particular organic substance or mixture is sufficiently distinctive to constitute a recognizable "signature". The signature of known substances are collected and divided into two classes based on some other known characteristic of the substances. A pattern recognition system classifies the signature of an unknown substance with reference to the two user-defined classes, thereby classifying the unknown substance with regard to the characteristic of interest, such as its suitability for a particular use.
Digital detection and processing of laser beacon signals for aircraft collision hazard warning
NASA Technical Reports Server (NTRS)
Sweet, L. M.; Miles, R. B.; Russell, G. F.; Tomeh, M. G.; Webb, S. G.; Wong, E. Y.
1981-01-01
A low-cost collision hazard warning system suitable for implementation in both general and commercial aviation is presented. Laser beacon systems are used as sources of accurate relative position information that are not dependent on communication between aircraft or with the ground. The beacon system consists of a rotating low-power laser beacon, detector arrays with special optics for wide angle acceptance and filtering of solar background light, microprocessors for proximity and relative trajectory computation, and pilot displays of potential hazards. The laser beacon system provides direct measurements of relative aircraft positions; using optimal nonlinear estimation theory, the measurements resulting from the current beacon sweep are combined with previous data to provide the best estimate of aircraft proximity, heading, minimium passing distance, and time to closest approach.
NASA Technical Reports Server (NTRS)
Manganaris, Stefanos; Fisher, Doug; Kulkarni, Deepak
1993-01-01
In this paper we address the problem of detecting and diagnosing faults in physical systems, for which neither prior expertise for the task nor suitable system models are available. We propose an architecture that integrates the on-line acquisition and exploitation of monitoring and diagnostic knowledge. The focus of the paper is on the component of the architecture that discovers classes of behaviors with similar characteristics by observing a system in operation. We investigate a characterization of behaviors based on best fitting approximation models. An experimental prototype has been implemented to test it. We present preliminary results in diagnosing faults of the Reaction Control System of the Space Shuttle. The merits and limitations of the approach are identified and directions for future work are set.
Barbés, Benigno; Azcona, Juan Diego; Prieto, Elena; de Foronda, José Manuel; García, Marina; Burguete, Javier
2015-09-08
A simple and independent system to detect and measure the position of a number of points in space was devised and implemented. Its application aimed to detect patient motion during radiotherapy treatments, alert of out-of-tolerances motion, and record the trajectories for subsequent studies. The system obtains the 3D position of points in space, through its projections in 2D images recorded by two cameras. It tracks black dots on a white sticker placed on the surface of the moving object. The system was tested with linear displacements of a phantom, circular trajectories of a rotating disk, oscillations of an in-house phantom, and oscillations of a 4D phantom. It was also used to track 461 trajectories of points on the surface of patients during their radiotherapy treatments. Trajectories of several points were reproduced with accuracy better than 0.3 mm in the three spatial directions. The system was able to follow periodic motion with amplitudes lower than 0.5 mm, to follow trajectories of rotating points at speeds up to 11.5 cm/s, and to track accurately the motion of a respiratory phantom. The technique has been used to track the motion of patients during radiotherapy and to analyze that motion. The method is flexible. Its installation and calibration are simple and quick. It is easy to use and can be implemented at a very affordable price. Data collection does not involve any discomfort to the patient and does not delay the treatment, so the system can be used routinely in all treatments. It has an accuracy similar to that of other, more sophisticated, commercially available systems. It is suitable to implement a gating system or any other application requiring motion detection, such as 4D CT, MRI or PET.
A macroscopic non-destructive testing system based on the cantilever-sample contact resonance
NASA Astrophysics Data System (ADS)
Fu, Ji; Lin, Lizhi; Zhou, Xilong; Li, Yingwei; Li, Faxin
2012-12-01
Detecting the inside or buried defects in materials and structures is always a challenge in the field of nondestructive testing (NDT). In this paper, enlightened by the operation principle of the contact resonance force microscopy or atomic force acoustic microscopy (AFAM), we proposed a macroscopic NDT system based on contact resonance of the cantilever-sample surface to detect the local stiffness variations in materials or structures. We fabricated a piezoelectric unimorph with the dimension typically of 150 mm × 8 mm × 2 mm to act as a macroscopic cantilever, whose flexural mode vibration was driven by a wideband power amplifier together with a signal generator. The vibration signal of the macroscopic cantilever is detected by a high sensitive strain gauge bonded on the cantilever surface which is much more stable than the laser diode sensor in AFAM, thus making it very suitable for outdoor operations. Scanning is realized by a three-dimensional motorized stage with the Z axis for pressing force setting. The whole system is controlled by a LabVIEW-based homemade software. Like the AFAM, this NDT system can also work in two modes, i.e., the single-frequency mode and the resonance-tracking mode. In the latter mode, the contact stiffness at each pixel of the sample can be obtained by using the measured contact resonance frequency and a beam dynamics model. Testing results of this NDT system on a grid structure with an opaque panel show that in both modes the prefabricated defect beneath the panel can be detected and the grid structures can be clearly "seen," which indicates the validity of this NDT system. The sensitivity of this NDT system was also examined.
A new method for measuring nocturnal tooth contacts.
Yamashita, S; Ai, M; Mizutani, H
1993-09-01
A new portable system for measuring nocturnal tooth contacts has been devised. This system was suitable for patients to take home and record tooth contacts by themselves. A micro photo sensor using optical fibres was applied to detect tooth contacts. The sensor and the target were accurately fixed to opposed molars, respectively on the same side, with removable metal attachments. Patients were instructed to set the attachment to their tooth each experimental night. In the present study, data was assembled for four or five nights in three subjects who were free of masticatory pain and dysfunction. Each subject showed an individual tooth contact pattern. It is suggested that this new system is useful and convenient for measuring nocturnal tooth contacts.
Array automated assembly task, phase 2. Low cost silicon solar array project
NASA Technical Reports Server (NTRS)
Rhee, S. S.; Jones, G. T.; Allison, K. T.
1978-01-01
Several modifications instituted in the wafer surface preparation process served to significantly reduce the process cost to 1.55 cents per peak watt in 1975 cents. Performance verification tests of a laser scanning system showed a limited capability to detect hidden cracks or defects, but with potential equipment modifications this cost effective system could be rendered suitable for applications. Installation of electroless nickel plating system was completed along with an optimization of the wafer plating process. The solder coating and flux removal process verification test was completed. An optimum temperature range of 500-550 C was found to produce uniform solder coating with the restriction that a modified dipping procedure is utilized. Finally, the construction of the spray-on dopant equipment was completed.
Protected transitional solution to transformational satellite communications
NASA Astrophysics Data System (ADS)
Brand, Jerry C.
2005-06-01
As the Warfighter progresses into the next generation battlefield, transformational communications become evident as an enabling technology. Satellite communications become even more vital as the battles range over greater non-contiguous spaces. While current satellite communications provide suitable beyond line-of-sight communications and the Transformational Communications Architecture (TCA) sets the stage for sound information exchange, a realizable transition must occur to ensure successful succession to this higher level. This paper addresses the need for a planned escalation to the next generation satellite communications architecture and offers near-term alternatives. Commercial satellite systems continue to enable the Warfighter to reach back to needed information resources, providing a large majority of available bandwidth. Four areas of concentration for transition include encrypted Telemetry, Tracking and Control (or Command) (TT&C), encrypted and covered data, satellite attack detection and protection, and operational mobility. Solution methodologies include directly embedding COMSEC devices in the satellites and terminals, and supplementing existing terminals with suitable equipment and software. Future satellites planned for near-term launches can be adapted to include commercial grade and higher-level secure equipment. Alternately, the expected use of programmable modems (Software Defined Radios (SDR)) enables incorporation of powerful cipher methods approaching military standards as well as waveforms suitable for on-the-move operation. Minimal equipment and software additions on the satellites can provide reasonable attack detection and protection methods in concert with the planned satellite usage. Network management suite modifications enable cohesive incorporation of these protection schemes. Such transitional ideas offer a smooth and planned transition as the TCA takes life.
NASA Astrophysics Data System (ADS)
Budy, Phaedra; Baker, Matthew; Dahle, Samuel K.
2011-10-01
Anthropogenic impairment of water bodies represents a global environmental concern, yet few attempts have successfully linked fish performance to thermal habitat suitability and fewer have distinguished co-varying water quality constraints. We interfaced fish bioenergetics, field measurements, and Thermal Remote Imaging to generate a spatially-explicit, high-resolution surface of fish growth potential, and next employed a structured hypothesis to detect relationships among measures of fish performance and co-varying water quality constraints. Our thermal surface of fish performance captured the amount and spatial-temporal arrangement of thermally-suitable habitat for three focal species in an extremely heterogeneous reservoir, but interpretation of this pattern was initially confounded by seasonal covariation of water residence time and water quality. Subsequent path analysis revealed that in terms of seasonal patterns in growth potential, catfish and walleye responded to temperature, positively and negatively, respectively; crappie and walleye responded to eutrophy (negatively). At the high eutrophy levels observed in this system, some desired fishes appear to suffer from excessive cultural eutrophication within the context of elevated temperatures whereas others appear to be largely unaffected or even enhanced. Our overall findings do not lead to the conclusion that this system is degraded by pollution; however, they do highlight the need to use a sensitive focal species in the process of determining allowable nutrient loading and as integrators of habitat suitability across multiple spatial and temporal scales. We provide an integrated approach useful for quantifying fish growth potential and identifying water quality constraints on fish performance at spatial scales appropriate for whole-system management.
Caprioara-Buda, M; Meyer, W; Jeynov, B; Corbisier, P; Trapmann, S; Emons, H
2012-07-01
The reliable quantification of genetically modified organisms (GMOs) by real-time PCR requires, besides thoroughly validated quantitative detection methods, sustainable calibration systems. The latter establishes the anchor points for the measured value and the measurement unit, respectively. In this paper, the suitability of two types of DNA calibrants, i.e. plasmid DNA and genomic DNA extracted from plant leaves, for the certification of the GMO content in reference materials as copy number ratio between two targeted DNA sequences was investigated. The PCR efficiencies and coefficients of determination of the calibration curves as well as the measured copy number ratios for three powder certified reference materials (CRMs), namely ERM-BF415e (NK603 maize), ERM-BF425c (356043 soya), and ERM-BF427c (98140 maize), originally certified for their mass fraction of GMO, were compared for both types of calibrants. In all three systems investigated, the PCR efficiencies of plasmid DNA were slightly closer to the PCR efficiencies observed for the genomic DNA extracted from seed powders rather than those of the genomic DNA extracted from leaves. Although the mean DNA copy number ratios for each CRM overlapped within their uncertainties, the DNA copy number ratios were significantly different using the two types of calibrants. Based on these observations, both plasmid and leaf genomic DNA calibrants would be technically suitable as anchor points for the calibration of the real-time PCR methods applied in this study. However, the most suitable approach to establish a sustainable traceability chain is to fix a reference system based on plasmid DNA.
Kushki, Azadeh; Khan, Ajmal; Brian, Jessica; Anagnostou, Evdokia
2015-03-01
Anxiety is associated with physiological changes that can be noninvasively measured using inexpensive and wearable sensors. These changes provide an objective and language-free measure of arousal associated with anxiety, which can complement treatment programs for clinical populations who have difficulty with introspection, communication, and emotion recognition. This motivates the development of automatic methods for detection of anxiety-related arousal using physiology signals. While several supervised learning methods have been proposed for this purpose, these methods require regular collection and updating of training data and are, therefore, not suitable for clinical populations, where obtaining labelled data may be challenging due to impairments in communication and introspection. In this context, the objective of this paper is to develop an unsupervised and real-time arousal detection algorithm. We propose a learning framework based on the Kalman filtering theory for detection of physiological arousal based on cardiac activity. The performance of the system was evaluated on data obtained from a sample of children with autism spectrum disorder. The results indicate that the system can detect anxiety-related arousal in these children with sensitivity and specificity of 99% and 92%, respectively. Our results show that the proposed method can detect physiological arousal associated with anxiety with high accuracy, providing support for technical feasibility of augmenting anxiety treatments with automatic detection techniques. This approach can ultimately lead to more effective anxiety treatment for a larger and more diverse population.
Leusch, Frederic D L; Neale, Peta A; Hebert, Armelle; Scheurer, Marco; Schriks, Merijn C M
2017-02-01
The presence of endocrine disrupting chemicals in the aquatic environment poses a risk for ecosystem health. Consequently there is a need for sensitive tools, such as in vitro bioassays, to monitor endocrine activity in environmental waters. The aim of the current study was to assess whether current in vitro bioassays are suitable to detect endocrine activity in a range of water types. The reviewed assays included androgenic (n=11), progestagenic (n=6), glucocorticoid (n=5), thyroid (n=5) and estrogenic (n=8) activity in both agonist and antagonist mode. Existing in vitro bioassay data were re-evaluated to determine assay sensitivity, with the calculated method detection limit compared with measured hormonal activity in treated wastewater, surface water and drinking water to quantify whether the studied assays were sufficiently sensitive for environmental samples. With typical sample enrichment, current in vitro bioassays are sufficiently sensitive to detect androgenic activity in treated wastewater and surface water, with anti-androgenic activity able to be detected in most environmental waters. Similarly, with sufficient enrichment, the studied mammalian assays are able to detect estrogenic activity even in drinking water samples. Fewer studies have focused on progestagenic and glucocorticoid activity, but some of the reviewed bioassays are suitable for detecting activity in treated wastewater and surface water. Even less is known about (anti)thyroid activity, but the available data suggests that the more sensitive reviewed bioassays are still unlikely to detect this type of activity in environmental waters. The findings of this review can help provide guidance on in vitro bioassay selection and required sample enrichment for optimised detection of endocrine activity in environmental waters. Copyright © 2016 Elsevier Ltd. All rights reserved.
Jiang, Keren; Wang, Yinan; Thakur, Garima; Kotsuchibashi, Yohei; Naicker, Selvaraj; Narain, Ravin; Thundat, Thomas
2017-05-10
A conjugated polymer interface consisting of an oxaborole containing polymer and a glycopolymer was used for achieving very high selectivity in dopamine (DA) detection. The optimum binding affinity between the polymers promotes the selectivity to DA through a displacement mechanism while remaining unaffected by other structurally related analogs and saccharide derivatives. Real-time detection of DA with very high selectivity and sensitivity has been demonstrated by immobilizing the polymer conjugates on surface plasmon resonance (SPR) and microcantilever (MCL) sensor platforms. Using the conjugated polymer sensing layer, the SPR biosensor was capable of detecting DA in the concentration range of 1 × 10 -9 to 1 × 10 -4 mol L -1 , whereas the MCL sensor showed a limit of detection (LOD) of 5 × 10 -11 mol L -1 . We find that the sensing mechanism is based on DA-induced reversible swelling of the conjugated polymer layer and this allows regeneration and reuse of the sensor multiple times. Also, we conclude that SPR is a suitable sensor platform for DA in-line detection at clinical level considering the detection time and stability, whereas MCL can achieve a much lower LOD.
A homogeneous biochemiluminescent assay for detection of influenza
NASA Astrophysics Data System (ADS)
Hui, Kwok Min; Li, Xiao Jing; Pan, Lu; Li, X. J.
2015-05-01
Current methods of rapid detection of influenza are based on detection of the nucleic acids or antigens of influenza viruses. Since influenza viruses constantly mutate leading to appearance of new strains or variants of viruses, these detection methods are susceptible to genetic changes in influenza viruses. Type A and B influenza viruses contain neuraminidase, an essential enzyme for virus replication which enables progeny influenza viruses leave the host cells to infect new cells. Here we describe an assay method, the homogeneous biochemiluminescent assay (HBA), for rapid detection of influenza by detecting viral neuraminidase activity. The assay mimics the light production process of a firefly: a viral neuraminidase specific substrate containing a luciferin moiety is cleaved in the presence of influenza virus to release luciferin, which becomes a substrate to firefly luciferase in a light production system. All reagents can be formulated in a single reaction mix so that the assay involves only one manual step, i.e., sample addition. Presence of Type A or B influenza virus in the sample leads to production of strong, stable and easily detectable light signal, which lasts for hours. Thus, this influenza virus assay is suitable for use in point-of-care settings.
Machine Learning Based Malware Detection
2015-05-18
A TRIDENT SCHOLAR PROJECT REPORT NO. 440 Machine Learning Based Malware Detection by Midshipman 1/C Zane A. Markel, USN...COVERED (From - To) 4. TITLE AND SUBTITLE Machine Learning Based Malware Detection 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM...suitably be projected into realistic performance. This work explores several aspects of machine learning based malware detection . First, we
The role of shape complexity in the detection of closed contours.
Wilder, John; Feldman, Jacob; Singh, Manish
2016-09-01
The detection of contours in noise has been extensively studied, but the detection of closed contours, such as the boundaries of whole objects, has received relatively little attention. Closed contours pose substantial challenges not present in the simple (open) case, because they form the outlines of whole shapes and thus take on a range of potentially important configural properties. In this paper we consider the detection of closed contours in noise as a probabilistic decision problem. Previous work on open contours suggests that contour complexity, quantified as the negative log probability (Description Length, DL) of the contour under a suitably chosen statistical model, impairs contour detectability; more complex (statistically surprising) contours are harder to detect. In this study we extended this result to closed contours, developing a suitable probabilistic model of whole shapes that gives rise to several distinct though interrelated measures of shape complexity. We asked subjects to detect either natural shapes (Exp. 1) or experimentally manipulated shapes (Exp. 2) embedded in noise fields. We found systematic effects of global shape complexity on detection performance, demonstrating how aspects of global shape and form influence the basic process of object detection. Copyright © 2015 Elsevier Ltd. All rights reserved.
Environmental Suitability of Vibrio Infections in a Warming Climate: An Early Warning System.
Semenza, Jan C; Trinanes, Joaquin; Lohr, Wolfgang; Sudre, Bertrand; Löfdahl, Margareta; Martinez-Urtaza, Jaime; Nichols, Gordon L; Rocklöv, Joacim
2017-10-10
Some Vibrio spp. are pathogenic and ubiquitous in marine waters with low to moderate salinity and thrive with elevated sea surface temperature (SST). Our objective was to monitor and project the suitability of marine conditions for Vibrio infections under climate change scenarios. The European Centre for Disease Prevention and Control (ECDC) developed a platform (the ECDC Vibrio Map Viewer) to monitor the environmental suitability of coastal waters for Vibrio spp. using remotely sensed SST and salinity. A case-crossover study of Swedish cases was conducted to ascertain the relationship between SST and Vibrio infection through a conditional logistic regression. Climate change projections for Vibrio infections were developed for Representative Concentration Pathway (RCP) 4.5 and RCP 8.5. The ECDC Vibrio Map Viewer detected environmentally suitable areas for Vibrio spp. in the Baltic Sea in July 2014 that were accompanied by a spike in cases and one death in Sweden. The estimated exposure-response relationship for Vibrio infections at a threshold of 16°C revealed a relative risk (RR)=1.14 (95% CI: 1.02, 1.27; p=0.024) for a lag of 2 wk; the estimated risk increased successively beyond this SST threshold. Climate change projections for SST under the RCP 4.5 and RCP 8.5 scenarios indicate a marked upward trend during the summer months and an increase in the relative risk of these infections in the coming decades. This platform can serve as an early warning system as the risk of further Vibrio infections increases in the 21st century due to climate change. https://doi.org/10.1289/EHP2198.
Environmental Suitability of Vibrio Infections in a Warming Climate: An Early Warning System
Trinanes, Joaquin; Lohr, Wolfgang; Sudre, Bertrand; Löfdahl, Margareta; Martinez-Urtaza, Jaime; Nichols, Gordon L.; Rocklöv, Joacim
2017-01-01
Background: Some Vibrio spp. are pathogenic and ubiquitous in marine waters with low to moderate salinity and thrive with elevated sea surface temperature (SST). Objectives: Our objective was to monitor and project the suitability of marine conditions for Vibrio infections under climate change scenarios. Methods: The European Centre for Disease Prevention and Control (ECDC) developed a platform (the ECDC Vibrio Map Viewer) to monitor the environmental suitability of coastal waters for Vibrio spp. using remotely sensed SST and salinity. A case-crossover study of Swedish cases was conducted to ascertain the relationship between SST and Vibrio infection through a conditional logistic regression. Climate change projections for Vibrio infections were developed for Representative Concentration Pathway (RCP) 4.5 and RCP 8.5. Results: The ECDC Vibrio Map Viewer detected environmentally suitable areas for Vibrio spp. in the Baltic Sea in July 2014 that were accompanied by a spike in cases and one death in Sweden. The estimated exposure–response relationship for Vibrio infections at a threshold of 16°C revealed a relative risk (RR)=1.14 (95% CI: 1.02, 1.27; p=0.024) for a lag of 2 wk; the estimated risk increased successively beyond this SST threshold. Climate change projections for SST under the RCP 4.5 and RCP 8.5 scenarios indicate a marked upward trend during the summer months and an increase in the relative risk of these infections in the coming decades. Conclusions: This platform can serve as an early warning system as the risk of further Vibrio infections increases in the 21st century due to climate change. https://doi.org/10.1289/EHP2198 PMID:29017986
Malá, Zdena; Gebauer, Petr
2017-10-06
Capillary isotachophoresis (ITP) is an electrophoretic technique offering high sensitivity due to permanent stacking of the migrating analytes. Its combination with electrospray-ionization mass-spectrometric (ESI-MS) detection is limited by the narrow spectrum of ESI-compatible components but can be compensated by experienced system architecture. This work describes a methodology for sensitive analysis of hydroxyderivatives of s-triazine herbicides, based on implementation of the concepts of moving-boundary isotachophoresis and of H + as essential terminating component into cationic ITP with ESI-MS detection. Theoretical description of such kind of system is given and equations for zone-related boundary mobilities are derived, resulting in a much more general definition of the effective mobility of the terminating H + zone than used so far. Explicit equations allowing direct calculation for selected simple systems are derived. The presented theory allows prediction of stacking properties of particular systems and easy selection of suitable electrolyte setups. A simple ESI-compatible system composed of acetic acid and ammonium with H + and ammonium as a mixed terminator was selected for the analysis of 2-hydroxyatrazine and 2-hydroxyterbutylazine, degradation products of s-triazine herbicides. The proposed method was tested with direct injection without any sample pretreatment and provided excellent linearity and high sensitivity with limits of detection below 100ng/L (0.5nM). Example analyses of unspiked and spiked drinking and river water are shown. Copyright © 2017 Elsevier B.V. All rights reserved.
Automated Microbiological Detection/Identification System
Aldridge, C.; Jones, P. W.; Gibson, S.; Lanham, J.; Meyer, M.; Vannest, R.; Charles, R.
1977-01-01
An automated, computerized system, the AutoMicrobic System, has been developed for the detection, enumeration, and identification of bacteria and yeasts in clinical specimens. The biological basis for the system resides in lyophilized, highly selective and specific media enclosed in wells of a disposable plastic cuvette; introduction of a suitable specimen rehydrates and inoculates the media in the wells. An automated optical system monitors, and the computer interprets, changes in the media, with enumeration and identification results automatically obtained in 13 h. Sixteen different selective media were developed and tested with a variety of seeded (simulated) and clinical specimens. The AutoMicrobic System has been extensively tested with urine specimens, using a urine test kit (Identi-Pak) that contains selective media for Escherichia coli, Proteus species, Pseudomonas aeruginosa, Klebsiella-Enterobacter species, Serratia species, Citrobacter freundii, group D enterococci, Staphylococcus aureus, and yeasts (Candida species and Torulopsis glabrata). The system has been tested with 3,370 seeded urine specimens and 1,486 clinical urines. Agreement with simultaneous conventional (manual) cultures, at levels of 70,000 colony-forming units per ml (or more), was 92% or better for seeded specimens; clinical specimens yielded results of 93% or better for all organisms except P. aeruginosa, where agreement was 86%. System expansion in progress includes antibiotic susceptibility testing and compatibility with most types of clinical specimens. Images PMID:334798
Kaneko, Keisuke; Sueyoshi, Noriyuki; Kameshita, Isamu; Ishida, Atsuhiko
2013-09-15
Blue-native electrophoresis (BNE) is a useful technique for analyzing protein complexes, but the Coomassie brilliant blue (CBB) dye used in BNE often hampers in-gel detection of enzymatic activity. Here we report an improved method, termed ink-native electrophoresis (INE), in which Pelikan 4001 fountain pen ink is used as a charge-shifting agent instead of CBB. INE is more suitable than BNE for in-gel detection of protein kinase activity after polyacrylamide gel electrophoresis (PAGE), and its performance in protein complex separation is comparable to that of conventional BNE. INE may provide a powerful tool to isolate and analyze various protein complexes. Copyright © 2013 Elsevier Inc. All rights reserved.
Electrochemical Biosensors for Rapid Detection of Foodborne Salmonella: A Critical Overview
Cinti, Stefano; Volpe, Giulia; Piermarini, Silvia; Delibato, Elisabetta; Palleschi, Giuseppe
2017-01-01
Salmonella has represented the most common and primary cause of food poisoning in many countries for at least over 100 years. Its detection is still primarily based on traditional microbiological culture methods which are labor-intensive, extremely time consuming, and not suitable for testing a large number of samples. Accordingly, great efforts to develop rapid, sensitive and specific methods, easy to use, and suitable for multi-sample analysis, have been made and continue. Biosensor-based technology has all the potentialities to meet these requirements. In this paper, we review the features of the electrochemical immunosensors, genosensors, aptasensors and phagosensors developed in the last five years for Salmonella detection, focusing on the critical aspects of their application in food analysis. PMID:28820458
A small-angle x-ray scattering system with a vertical layout
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Zhen; Chen, Xiaowei; Meng, Lingpu
A small-angle x-ray scattering (SAXS) system with a vertical layout (V-SAXS) has been designed and constructed for in situ detection on nanostructures, which is well suitable for in situ study on self-assembly of nanoparticles at liquid interface and polymer processing. A steel-tower frame on a reinforced basement is built as the supporting skeleton for scattering beam path and detector platform, ensuring the system a high working stability and a high operating accuracy. A micro-focus x-ray source combining parabolic three-dimensional multi-layer mirror and scatteringless collimation system provides a highly parallel beam, which allows us to detect the very small angle range.more » With a sample-to-detector distance of 7 m, the largest measurable length scale is 420 nm in real space. With a large sample zone, it is possible to install different experimental setups such as film stretching machine, which makes the system perfect to follow the microstructures evolution of materials during processing. The capability of the V-SAXS on in situ study is tested with a drying experiment of a free latex droplet, which confirms our initial design.« less
NASA Astrophysics Data System (ADS)
Zhang, Hongtao; Wang, Pengfei
2012-06-01
The current schemes of detecting the status of passengers in airplanes cannot satisfy the more strict regulations recently released by the United States Transportation Security Administration. In basis of investigation on the current seat occupancy sensors for vehicles, in this paper we present a novel scheme of seat occupancy sensors based on Fiber Bragg Grating technology to improve the in-flight security of airplanes. This seat occupancy sensor system can be used to detect the status of passengers and to trigger the airbags to control the inflation of air bags, which have been installed in the airplanes of some major airlines under the new law. This scheme utilizes our previous research results of Weight-In- Motion sensor system based on optical fiber Bragg grating. In contrast to the current seat occupancy sensors for vehicles, this new seat occupancy sensor has so many merits that it is very suitable to be applied in aerospace industry or high speed railway system. Moreover, combined with existing Fiber Bragg Grating strain or temperature sensor systems built in airplanes, this proposed method can construct a complete airline passenger management system.
An Energy Efficient ECG Signal Processor Detecting Cardiovascular Diseases on Smartphone.
Jain, Sanjeev Kumar; Bhaumik, Basabi
2017-04-01
A novel disease diagnostic algorithm for ECG signal processing based on forward search is implemented in Application Specific Integrated Circuit (ASIC) for cardiovascular disease diagnosis on smartphone. An ASIC is fabricated using 130-nm CMOS low leakage process technology. The area of our PQRST ASIC is 1.21 mm 2 . The energy dissipation of PQRST ASIC is 96 pJ with a supply voltage of 0.9 V. The outputs from the ASIC are fed to an Android application that generates diagnostic report and can be sent to a cardiologist via email. The ASIC and Android application are verified for the detection of bundle branch block, hypertrophy, arrhythmia and myocardial infarction using Physionet PTB diagnostic ECG database. The failed detection rate is 0.69%, 0.69%, 0.34% and 1.72% for bundle branch block, hypertrophy, arrhythmia and myocardial infarction respectively. The AV block is detected in all the three patients in the Physionet St. Petersburg arrhythmia database. Our proposed ASIC together with our Android application is the most suitable for an energy efficient wearable cardiovascular disease detection system.
NASA Technical Reports Server (NTRS)
Athale, R.; Lee, S. H.
1976-01-01
Various defects in mass-produced pictures transmitted to earth from a satellite are investigated. It is found that the following defects are readily detectable via Fourier spectrum analysis: (1) bit slip, (2) breakup causing loss of image, and (3) disabled track at the top of the imagery. The scratches made on the film during mass production, which are difficult to detect by visual observation, also show themselves readily in Fourier spectrum analysis. A relation is established between the number of scratches, their width and depth and the intensity of their Fourier spectra. Other defects that are found to be equally suitable for Fourier spectrum analysis or visual (image analysis) detection are synchronous loss without blurring of image, and density variation in gray scale. However, the Fourier spectrum analysis is found to be unsuitable for detection of such defects as pin holes, annotation error, synchronous loss with blurring of images, and missing image in the beginning of the work order. The design of an automated, real time system, which will reject defective films, is treated.
Non-contact biomedical photoacoustic and ultrasound imaging
NASA Astrophysics Data System (ADS)
Rousseau, Guy; Gauthier, Bruno; Blouin, Alain; Monchalin, Jean-Pierre
2012-06-01
The detection of ultrasound in photoacoustic tomography (PAT) usually relies on ultrasonic transducers in contact with the biological tissue through a coupling medium. This is a major drawback for important potential applications such as surgery. Here we report the use of a remote optical method, derived from industrial laser-ultrasonics, to detect ultrasound in tissues. This approach enables non-contact PAT (NCPAT) without exceeding laser exposure safety limits. The sensitivity of the method is based on the use of suitably shaped detection laser pulses and a confocal Fabry-Perot interferometer in differential configuration. Reliable image reconstruction is obtained by measuring remotely the surface profile of the tissue with an optical coherence tomography system. The proposed method also allows non-contact ultrasound imaging (US) by applying a second reconstruction algorithm to the data acquired for NCPAT. Endogenous and exogenous inclusions exhibiting optical and acoustic contrasts were detected ex vivo in chicken breast and calf brain specimens. Inclusions down to 0.3 mm in size were detected at depths exceeding 1 cm. The method could expand the scope of photoacoustic and US to in-vivo biomedical applications where contact is impractical.
Design and performance of heart assist or artificial heart control systems
NASA Technical Reports Server (NTRS)
Webb, J. A., Jr.; Gebben, V. D.
1978-01-01
The factors leading to the design of a controlled driving system for either a heart assist pump or artificial heart are discussed. The system provides square pressure waveform to drive a pneumatic-type blood pump. For assist usage the system uses an R-wave detector circuit that can detect the R-wave of the electrocardiogram in the presence of electrical disturbances. This circuit provides a signal useful for synchronizing an assist pump with the natural heart. It synchronizes a square wave circuit, the output of which is converted into square waveforms of pneumatic pressure suitable for driving both assist device and artificial heart. The pressure levels of the driving waveforms are controlled by means of feedback channels to maintain physiological regulation of the artificial heart's output flow. A more compact system that could achieve similar regulatory characteristics is also discussed.
[Extraction method suitable for detection of unheated crustaceans including cephalothorax by ELISA].
Shibahara, Yusuke; Yamada, Itta; Uesaka, Yoshihiko; Uneo, Noriko; Abe, Akihisa; Ohashi, Eiji; Shiomi, Kazuo
2009-08-01
When unheated whole samples of crustaceans (shrimp, prawn and crab) were analyzed with our ELISA kit (FA test EIA-Crustacean 'Nissui') using anti-tropomyosin antibodies, a remarkable reduction in reactivity was recognized. This reduction in activity was found to be due to the digestion of tropomyosin during the extraction process by proteases contained in cephalothorax. To avoid the digestion of tropomyosin by proteases, we developed an extraction method (heating method) suitable for the detection of tropomyosin in unheated crustaceans including cephalothorax. Experiments with unheated whole samples of various species of crustaceans confirmed that the heating method greatly improved the low reactivity in the standard method; the heating method gave extraction efficiencies of as high as 93-107%. Various processed crustaceans with cephalothorax, such as dry products (unheated or weakly heated products) and pickles in soy sauce (unheated products), that showed low reactivity with the standard method were confirmed to give superior results with the heating method. These results indicated that the developed heating method is suitable for detecting unheated crustaceans with cephalothorax by means of the ELISA kit.
Efficient Third Harmonic Generation for Wind Lidar Applications
NASA Technical Reports Server (NTRS)
Mordaunt, David W.; Cheung, Eric C.; Ho, James G.; Palese, Stephen P.
1998-01-01
The characterization of atmospheric winds on a global basis is a key parameter required for accurate weather prediction. The use of a space based lidar system for remote measurement of wind speed would provide detailed and highly accurate data for future weather prediction models. This paper reports the demonstration of efficient third harmonic conversion of a 1 micrometer laser to provide an ultraviolet (UV) source suitable for a wind lidar system based on atmospheric molecular scattering. Although infrared based lidars using aerosol scattering have been demonstrated to provide accurate wind measurement, a UV based system using molecular or Rayleigh scattering will provide accurate global wind measurements, even in those areas of the atmosphere where the aerosol density is too low to yield good infrared backscatter signals. The overall objective of this work is to demonstrate the maturity of the laser technology and its suitability for a near term flight aboard the space shuttle. The laser source is based on diode-pumped solid-state laser technology which has been extensively demonstrated at TRW in a variety of programs and internal development efforts. The pump laser used for the third harmonic demonstration is a breadboard system, designated the Laser for Risk Reduction Experiments (LARRE), which has been operating regularly for over 5 years. The laser technology has been further refined in an engineering model designated as the Compact Advanced Pulsed Solid-State Laser (CAPSSL), in which the laser head was packaged into an 8 x 8 x 18 inch volume with a weight of approximately 61 pounds. The CAPSSL system is a ruggedized configuration suitable for typical military applications. The LARRE and CAPSSL systems are based on Nd:YAG with an output wavelength of 1064 nm. The current work proves the viability of converting the Nd:YAG fundamental to the third harmonic wavelength at 355 nm for use in a direct detection wind lidar based on atmospheric Rayleigh scattering.
Wireless health monitoring of cracks in structures with MEMS-IDT sensors
NASA Astrophysics Data System (ADS)
Kim, Jae-Sung; Vinoy, K. J.; Varadan, Vijay K.
2002-07-01
The integration of MEMS, IDTs and required microelectronics and conformal antennas to realize programmable, robust and low cost passive microsensors suitable for many military structures and systems including aircraft, missiles and munitions is presented in this paper. The technology is currently being applied to the structural health monitoring of accelerometers, gyroscopes and vibration monitoring devices with signal processing electronics to provide real- time indicators of incipient failure of aircraft components with a known history of catastrophic failure due to fracture. Recently a combination of the need for safety in the air and the desire to control costs is encouraging the use of in-flight monitoring of aircraft components and systems using light-weight, wireless and cost effective microsensors and MEMS. An in-situ Aircraft structural health monitoring system, with sensors embedded in the composite structure or surface-mounted on the structure, would permit the timely detection of damage in aircraft. Micromachining offers the potential for fabricating a range of microsensors and MEMS for structural applications including load, vibration and acoustics characteristics and monitoring. Such microsensors are extremely small; they can be embedded into structural materials, can be mass-produced and are therefore potentially cheap. Additionally a range of sensor types can be integrated onto a single chip with built-in electronics and ASIC, providing a low power microsystem. The smart sensors are being developed using the standard microelectronics and micromachining in conjunction with novel Penn State smart electronics or wireless communication systems suitable for condition monitoring of aircraft structures in-flight. A hybrid accelerometer and gyroscope in a single chip suitable for inertial navigation system and other microsensors for health monitoring and condition-based maintenance of structures, drag sensing and control of aircraft, strain and deflection of structures and systems, ice sensing on aircraft, remote temperature and humidity measurement of propellant in munitions, chemical sensing, etc. are discussed.
Wireless microsensors for health monitoring of aircraft structures
NASA Astrophysics Data System (ADS)
Varadan, Vijay K.
2003-01-01
The integration of MEMS, IDTs (interdigital transducers) and required microelectronics and conformal antennas to realize programmable, robust and low cost passive microsensors suitable for many military structures and systems including aircraft, missiles and munitions is presented in this paper. The technology is currently being applied to the structural health monitoring of critical aircraft components. The approach integrates acoustic emission, strain gauges, MEMS accelerometers, gyroscopes and vibration monitoring devices with signal processing electronics to provide real-time indicators of incipient failure of aircraft components with a known history of catastrophic failure due to fracture. Recently a combination of the need for safety in the air and the desire to control costs is encouraging the use of in-flight monitoring of aircraft components and systems using light-weight, wireless and cost effective microsensors and MEMS. An in-situ Aircraft structural health monitoring (ASHM) system, with sensors embedded in the composite structure or surface-mounted on the structure, would permit the timely detection of damage in aircraft. Micromachining offers the potential for fabricating a range of microsensors and MEMS for structural applications including load, vibration and acoustics characterization and monitoring. Such microsensors are extremely small; they can be embedded into structural materials, can be mass-produced and are therefore potentially cheap. Additionally a range of sensor types can be integrated onto a single chip with built-in electronics and ASIC (Application Specific Integrated Circuit), providing a low power Microsystems. The smart sensors are being developed using the standard microelectronics and micromachining in conjunction with novel Penn State smart electronics or wireless communication systems suitable for condition monitoring of aircraft structures in-flight. A hybrid accelerometer and gyroscope in a single chip suitable for inertial navigation system and other microsensors for health monitoring and condition-based maintenance of structures, drag sensing and control of aircraft, strain and deflection of structures and systems, ice sensing on aircraft, remote temperature and humidity measurement of propellant in munitions, chemical sensing, etc. are discussed.
Detection of Biological Pathogens Using Multiple Wireless Magnetoelastic Biosensors
NASA Astrophysics Data System (ADS)
Shen, Wen
A number of recent, high-profile incidences of food-borne illness spreading through the food supply and the use of anthrax by terrorists after the September 11, 2001 attacks have demonstrated the need for new technologies that can rapidly detect the presence of biological pathogens. A bevy of biosensors show excellent detection sensitivity and specificity. However, false positive and false negative signals remain one of the primary reasons that many of these newly developed biosensors have not found application in the marketplace. The research described in this dissertation focuses on developing a free-standing magnetoelastic based bio-sensing system using a pulse method. This method allows fast detection, eliminates the bias magnetic field that is necessary in current methods, makes the system more simply and suitable for in-field detection. This system has two pairs of transformer coils, where a measurement sensor and a control sensor can be put in each pair of coils. The control sensor is used to compensate for environmental variables. The effect of pulse power on the performance of the magnetoelastic sensors in the pulse system is studied. The system is found to have excellent stability, good detection repeatability when used with multiple sensors. This research has investigated and demonstrated a multiple sensors approach. Because it will involve the simultaneous measurement of many sensors, it will significantly reduce problems encountered with false positive indications. The positioning and interference of sensors are investigated. By adding a multi-channel structure to the pulse detection system, the effect of sensor interference is minimized. The result of the repeatability test shows that the standard deviation when measuring three 1 mm magnetoelastic sensors is around 500 Hz, which is smaller than the minimum requirement for actual spores/bacteria detection. Magnetoelastic sensors immobilized with JRB7 phages and E2 phages have been used to specifically detect Bacillus anthracis spores and Salmonella typhimurium bacteria. The real-time monitoring of the detection of B. anthracis spores in a flowing system was performed using 2 mm sensors and 1 mm sensors. The detection of S. typhimurium in air has been performed using the pulse based system with both single and grouped sensors. Because grouped sensor detection involves the simultaneous measurement of many sensors, statistical evaluation shows that it can significantly reduce problems encountered with false positive indications. This method has been implemented in an investigation of a method that allows direct detection of S. typhimurium on cantaloupe surfaces. It has been demonstrated that multiple E2 phage based magnetoelastic sensors are able to detect Salmonella directly on fresh cantaloupe surfaces. Confirmation of the spore or bacteria binding to the sensor surfaces was achieved through SEM study of the sensor surfaces.
Papandreou, Georgios; Zorpas, Kostas; Archontaki, Helen
2011-11-01
Simultaneous determination of aniracetam and its related impurities (2-pyrrolidinone, p-anisic acid, 4-p-anisamidobutyric acid and (p-anisoyl)-4-methyl-2-pyrrolidinone) was accomplished in the bulk drug and in a tablet formulation using a high performance liquid chromatographic method with UV detection. Separation was achieved on a Hypersil BDS-CN column (150 mm × 4.0 mm, 5 μm) using a gradient elution program with solvent A composed of phosphate buffer (pH 4.0; 0.010 M) and solvent B of acetonitrile-phosphate buffer (pH 4.0; 0.010 M) (90:10, v/v). The flow rate of the mobile phase was 1.0 mL min(-1) and the total elution time, including the column re-equilibration, was approximately 20 min. The UV detection wavelength was varied appropriately among 210, 250 and 280 nm. Injection volume was 20 μL and experiments were conducted at ambient temperature. The developed method was validated in terms of system suitability, selectivity, linearity, range, precision, accuracy, limits of detection and quantification for the impurities, short term and long term stability of the analytes in the prepared solutions and robustness, following the ICH guidelines. Therefore, the proposed method was suitable for the simultaneous determination of aniracetam and its studied related impurities. Copyright © 2011 Elsevier B.V. All rights reserved.
Fraulo, Pasquale; Morena, Carmelo; Costa, Antonella
2014-10-01
Anisakidae larvae belonging to the genera Anisakis and Pseudoterranova, are the most responsible for zoonosis transmitted by fish products (anisakidosis). Acquired by the consumption of raw or undercooked marine fish or squid, the anisakid larvae may cause pathogenic diseases like gastric or intestinal anisakiasis and gastro-allergic disorders. In accordance with current EU legislation, the fresh fish products must be inspected visually in order to detect the possible presence of visible parasites. It is recognized that the visual method is not accurate enough to detect the larvae of parasites in food preparations containing raw or practically raw seafood and it clearly emerges that the official system of control needs to be able to utilise an most efficient analytical technique. In this work, the authors have drawn up and validated an analytical method, which involves artificial digestion and the use of a heated magnetic stirrer, based on the EU Regulation n. 2075/2005. The larvae isolated are then subjected to morphological identification at genus level by using optical microscope. The method, proved to be suitable for the detection of live and dead larvae of anisakidae in ready-to-eat foodstuffs containing raw fish or cephalopods and it is fast and accurate. The method showed high levels of sensitivity and specificity, and the suitability of its use in official food control was confirmed. Its use should be incorporated systematically into specific monitoring programs for the control of foodstuffs containing raw fish products.
Liu, Yajing; Zhu, Pan; Huang, Zhiwei; Zhou, Li; Shi, Ping
2018-02-15
A well-known suicide gene therapy approach, cytosine deaminase (CD) in combination with prodrug 5-flurocytosine (5-FC), has become an effective strategy of tumor treatment. However, there are short of simple and convenient detection methods to evaluate the efficiency of 5-FC conversion to 5-fluorouracil (5-FU) in human cells carrying various CD/5-FC systems. In this study, we developed an effective capillary zone electrophoresis (CZE) method to simultaneously measure 5-FC and 5-FU in cells carrying CD/5-FC suicide gene system. Under the condition of 60 mM borate buffer (pH 9.5) and 25 kV separation voltage with 0.5 psi × 15 s injection in 210 nm, the separation of 5-FC and 5-FU could be completely achieved within 15 min. The linearity of the calibration curve of standard 5-FC and 5-FU was in the range from 1 to 1000 μM (r 2 > 0.999) and their recoveries were 98.4% and 96.0%, respectively. Due to the simple sample preparation and easy detection, this method is suitable for the study of the conversion efficiency of CD/5-FC suicide gene system. It aims to intuitively evaluate CD/5-FC systems and helps to guide the improvement of more effective CD/5-FC suicide gene systems. Copyright © 2018. Published by Elsevier B.V.
Wang, Jian; Liu, Yuan; Zhang, Junhua; Han, Zhengzheng; Wang, Wei; Liu, Yang; Wei, Dong; Huang, Wei
2017-11-01
Large-scale expression of β 2 -adrenergic receptor (β 2 -AR) in functional form is necessary for establishment of receptor assays for detecting illegally abused β-adrenergic agonists (β-agonists). Cell-based heterologous expression systems have manycritical difficulties in synthesizing this membrane protein, such as low protein yields and aberrant folding. To overcome these challenges, the main objective of the present work was to synthesize large amounts of functional β 2 -AR in a cell-free system based on Escherichia coli extracts. A codon-optimized porcine β 2 -AR gene (codon adaptation index: 0.96) suitable for high expression in E. coli was synthesized and transcribed to the cell-free system, which contributed to increase the expression up to 1.1 mg/ml. After purification using Ni-affinity chromatography, the bioactivity of the purified receptor was measured by novel enzyme-linked receptor assays. It was determined that the relative affinities of the purified β 2 -AR for β-agonists in descending order were as follows: clenbuterol > salbutamol > ractopamine. Moreover, their IC 50 values were 45.99, 60.38, and 78.02 µg/liter, respectively. Although activity of the cell-free system was slightly lower than activity of systems based on insect and mammalian cells, this system should allow production of β 2 -AR in bulk amounts sufficient for the development of multianalyte screening methods for detecting β-agonist residues.
Bronze Alloy Development for Zinc Vapor Capture
Korinko, Paul S.
2017-04-24
After gamma-emitting 65Zinc was detected in a vacuum pumping system contained in a tritium glovebox, a series of experiments were undertaken to develop a method and material to trap zinc vapors in an area that is more suitable for preventing dose to workers. In this study, bronze alloys with 0–30% tin were prepared using a powder metallurgical process and exposed to three levels of zinc vapors. Furthermore, all of the alloys demonstrated acceptable zinc gettering capacity; however, low tin content bronzes are considered for further testing.
Namiki, Ryo; Koashi, Masato; Imoto, Nobuyuki
2008-09-05
We generalize the experimental success criterion for quantum teleportation (memory) in continuous-variable quantum systems to be suitable for a non-unit-gain condition by considering attenuation (amplification) of the coherent-state amplitude. The new criterion can be used for a nonideal quantum memory and long distance quantum communication as well as quantum devices with amplification process. It is also shown that the framework to measure the average fidelity is capable of detecting all Gaussian channels in the quantum domain.
NASA Astrophysics Data System (ADS)
Shiramizu, Hideyuki; Kuroda, Chiaki; Ohki, Yoshimichi; Shima, Takayuki; Wang, Xiaomin; Fujimaki, Makoto
2018-03-01
We have developed an optical disk system for imaging transmitted light from Escherichia coli dispersed on an optical disk. When E. coli was stained using Bismarck brown, the transmittance was found to decrease in images obtained at λ = 405 nm. The results indicate that transmittance imaging is suitable for finding the difference in light intensity between stained and unstained E. coli, whereas the reflectance images were scarcely changed by staining. Therefore, E. coli can be selectively discriminated from abiotic contaminants using transmittance imaging.
NASA Astrophysics Data System (ADS)
Antolín-Urbaneja, J. C.; Eguizabal, I.; Briz, N.; Dominguez, A.; Estensoro, P.; Secchi, A.; Varriale, A.; Di Giovanni, S.; D'Auria, S.
2013-05-01
Several techniques for detecting chemical drug precursors have been developed in the last decade. Most of them are able to identify molecules at very low concentration under lab conditions. Other commercial devices are able to detect a fixed number and type of target substances based on a single detection technique providing an absence of flexibility with respect to target compounds. The construction of compact and easy to use detection systems providing screening for a large number of compounds being able to discriminate them with low false alarm rate and high probability of detection is still an open concern. Under CUSTOM project, funded by the European Commission within the FP7, a stand-alone portable sensing device based on multiple techniques is being developed. One of these techniques is based on the LED induced fluorescence polarization to detect Ephedrine and Benzyl Methyl Keton (BMK) as a first approach. This technique is highly selective with respect to the target compounds due to the generation of properly engineered fluorescent proteins which are able to bind the target analytes, as it happens in an "immune-type reaction". This paper deals with the advances in the design, construction and validation of the LED induced fluorescence sensor to detect BMK analytes. This sensor includes an analysis module based on high performance LED and PMT detector, a fluidic system to dose suitable quantities of reagents and some printed circuit boards, all of them fixed in a small structure (167mm × 193mm × 228mm) with the capability of working as a stand-alone application.
Light-Actuated Micromechanical Relays for Zero-Power Infrared Detection
2017-03-01
Light-Actuated Micromechanical Relays for Zero-Power Infrared Detection Zhenyun Qian, Sungho Kang, Vageeswar Rajaram, Cristian Cassella, Nicol E...near-zero power infrared (IR) detection . Differently from any existing switching element, the proposed LMR relies on a plasmonically-enhanced...chip enabling the monolithic fabrication of multiple LMRs connected together to form a logic topology suitable for the detection of specific
Study of the suitability of DUO plastic bags for the storage of dynamites.
Sáiz, Jorge; Ferrando, José-Luis; Atoche, Juan-Carlos; García-Ruiz, Carmen
2013-10-10
A comparative study on the retentiveness of two plastic bags (DUO and Royal Pack) has been carried out by gas chromatography with mass spectrometry detection. Two types of dynamites were packed in both plastic bags. The bags were placed into glass jars and headspace analyses were performed over 11 weeks to detect whether the volatile constituents of the dynamites were released from the bags. DUO plastic bags showed much better retentiveness than Royal Pack plastic bags. Ethylene glycol dinitrate (EGDN) was quickly detected in the headspace of the glass jars containing Royal Pack plastic bags after 1 week of storage. On the contrary, only a weak signal of EGDN, which was not detectable in the total ion chromatogram, was detected after 11 weeks of storage. Moreover, DUO plastic bags have shown less background signals than the Royal Pack bags, being the former bags much more suitable for the storage of dynamites. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Huynh, Phat; Do, Trong-Hop; Yoo, Myungsik
2017-02-10
This paper proposes a probability-based algorithm to track the LED in vehicle visible light communication systems using a camera. In this system, the transmitters are the vehicles' front and rear LED lights. The receivers are high speed cameras that take a series of images of the LEDs. ThedataembeddedinthelightisextractedbyfirstdetectingthepositionoftheLEDsintheseimages. Traditionally, LEDs are detected according to pixel intensity. However, when the vehicle is moving, motion blur occurs in the LED images, making it difficult to detect the LEDs. Particularly at high speeds, some frames are blurred at a high degree, which makes it impossible to detect the LED as well as extract the information embedded in these frames. The proposed algorithm relies not only on the pixel intensity, but also on the optical flow of the LEDs and on statistical information obtained from previous frames. Based on this information, the conditional probability that a pixel belongs to a LED is calculated. Then, the position of LED is determined based on this probability. To verify the suitability of the proposed algorithm, simulations are conducted by considering the incidents that can happen in a real-world situation, including a change in the position of the LEDs at each frame, as well as motion blur due to the vehicle speed.
Powerful conveyer belt real-time online detection system based on x-ray
NASA Astrophysics Data System (ADS)
Rong, Feng; Miao, Chang-yun; Meng, Wei
2009-07-01
The powerful conveyer belt is widely used in the mine, dock, and so on. After used for a long time, internal steel rope of the conveyor belt may fracture, rust, joints moving, and so on .This would bring potential safety problems. A kind of detection system based on x-ray is designed in this paper. Linear array detector (LDA) is used. LDA cost is low, response fast; technology mature .Output charge of LDA is transformed into differential voltage signal by amplifier. This kind of signal have great ability of anti-noise, is suitable for long-distance transmission. The processor is FPGA. A IP core control 4-channel A/D convertor, achieve parallel output data collection. Soft-core processor MicroBlaze which process tcp/ip protocol is embedded in FPGA. Sampling data are transferred to a computer via Ethernet. In order to improve the image quality, algorithm of getting rid of noise from the measurement result and taking gain normalization for pixel value is studied and designed. Experiments show that this system work well, can real-time online detect conveyor belt of width of 2.0m and speed of 5 m/s, does not affect the production. Image is clear, visual and can easily judge the situation of conveyor belt.