Adverse effects of pesticides on central auditory functions in tobacco growers.
França, Denise Maria Vaz Romano; Bender Moreira Lacerda, Adriana; Lobato, Diolen; Ribas, Angela; Ziliotto Dias, Karin; Leroux, Tony; Fuente, Adrian
2017-04-01
To investigate the effects of exposure to pesticides on the central auditory functions (CAF) of Brazilian tobacco growers. This was a cross-sectional study carried out between 2010 and 2012. Participants were evaluated with two behavioural procedures to investigate CAF, the random gap detection test (RGDT) and the dichotic digit test in Portuguese (DDT). A total of 22 growers exposed to pesticides (study group) and 21 subjects who were not exposed to pesticides (control group) were selected. No significant differences between groups were observed for pure-tone thresholds. A significant association between pesticide exposure and the results for RGDT and DDT was found. Significant differences between pesticide-exposed and nonexposed subjects were found for RGDT frequency average and DDT binaural average, when including age and hearing level as covariates. Age was significantly associated with RGDT frequency average, DDT left ear score, DDT binaural average and DDT right ear advantage. Hearing levels were not significantly associated with any of the test scores. The relative risk of failing the DDT and RGDT for the study group was 1.88 (95% CI: 1.10-3.20) and 1.74 (95% CI: 1.06-2.86), respectively, as compared with the control group. The results showed that tobacco growers exposed to pesticides exhibited signs of central auditory dysfunction characterised by decrements in temporal processing and binaural integration processes/abilities.
Central auditory processing in patients with spinocerebellar ataxia.
Zeigelboim, Bianca Simone; de Carvalho, Hugo Amilton Santos; Teive, Hélio Afonso Ghizoni; Liberalesso, Paulo Breno Noronha; Jurkiewicz, Ari Leon; da Silva Abdulmassih, Edna Márcia; Marques, Jair Mendes; Cordeiro, Mara Lúcia
2015-09-01
Autosomal dominant spinocerebellar ataxias (SCAs) are a group of rare and heterogeneous neurodegenerative diseases characterized by the presence of progressive cerebellar ataxia. Although the symptomatology of SCAs is well known, information regarding central auditory functioning in these patients is lacking. Therefore, we assessed the central auditory processing disorders (CAPD) in patients with different subtypes of SCA. In a retrospective cross-sectional study, we subjected 43 patients with SCAs to otorhinolaryngological, audiological, Brainstem Auditory Evoked Potential (BAEP) and acoustic immittance evaluations as well as CAPD tests, namely the Standard Spondaic Word (SSW) and the Random Gap Detection Test (RGDT). Most patients (83.7%) reported an imbalance when walking; many reported difficulty speaking (48.8%), dizziness (41.8%), and dysphagia (39.5%). In the audiometric test, 14/43 patients (32.5%) presented alterations, including 4/12 patients with SCA3 (33.3%), 1/8 patients with SCA2 (12.5%), 1/1 patient with SCA4 (100%), 1/1 patient with SCA6 (100%), 1/1 patient with SCA7 (100%), 3/6 patients with SCA10 (50%), and 3/14 patients with an undetermined type of SCA (21.4%). In the BAEP test, 20/43 patients (46.5%) presented alterations (11.6% na orelha esquerda e 34.9% bilateralmente), including 7/12 patients with SCA3 (58.3%), 5/8 patients with SCA2 (62.5%), 1/1 patient with SCA4 (100%), 1/1 patient with SCA6 (100%), 1/1 patient with SCA7 (100%), 4/6 patients with SCA10 (66.7%), and 2/14 patients with an undetermined type of SCA (14.2%). In the SSW, 22/40 patients (55%) presented alterations (2.5% in the right ear, 15% in the left ear, and 37.5% bilaterally), including 6/10 patients (60%) with SCA3, 3/8 (37.5%) with SCA2, 1/1 (100%) with SCA4, 1/1 (100%) with SCA6, 1/1 (100%) with SCA7, 4/5 (80%) with SCA10, and 8/14 (57.1%) with an undetermined type SCA. For the RGDT, 30/40 patients (75%) presented alterations, including 8/10 (80%) with SCA3, 6/8 (75%) with SCA2, 1/1 (100%) with SCA4, 1/1 (100%) with SCA6, 1/1 (100%) with SCA7, 4/5 (80%) with SCA10, and 9/14 (64.3%) with an undetermined type of SCA. In immittance testing, 19/43 patients (44.1%) presented alterations, including 6/12 (50%) with SCA3, 4/8 (50%) with SCA2, 1/1 (100%) with SCA4, 1/1 (100%) with SCA6, 1/1 (100%) with SCA7, 2/6 (33.3%) with SCA10, and 4/14 (28.6%) with an undetermined type of SCA. A majority of patients exhibited SSW test deficits, with a predominance of bilateralism, and three-fourths had impaired RGDT performance, pointing to difficulties with binaural integration and temporal resolution. Assessment of CAPD is important for therapeutic follow ups in patients with SCA. Copyright © 2015 Elsevier B.V. All rights reserved.
Bellis, Teri James; Ross, Jody
2011-09-01
It has been suggested that, in order to validate a diagnosis of (C)APD (central auditory processing disorder), testing using direct cross-modal analogs should be performed to demonstrate that deficits exist solely or primarily in the auditory modality (McFarland and Cacace, 1995; Cacace and McFarland, 2005). This modality-specific viewpoint is controversial and not universally accepted (American Speech-Language-Hearing Association [ASHA], 2005; Musiek et al, 2005). Further, no such analogs have been developed to date, and neither the feasibility of such testing in normally functioning individuals nor the concurrent validity of cross-modal analogs has been established. The purpose of this study was to investigate the feasibility of cross-modal testing by examining the performance of normal adults and children on four tests of central auditory function and their corresponding visual analogs. In addition, this study investigated the degree to which concurrent validity of auditory and visual versions of these tests could be demonstrated. An experimental repeated measures design was employed. Participants consisted of two groups (adults, n=10; children, n=10) with normal and symmetrical hearing sensitivity, normal or corrected-to-normal visual acuity, and no family or personal history of auditory/otologic, language, learning, neurologic, or related disorders. Visual analogs of four tests in common clinical use for the diagnosis of (C)APD were developed (Dichotic Digits [Musiek, 1983]; Frequency Patterns [Pinheiro and Ptacek, 1971]; Duration Patterns [Pinheiro and Musiek, 1985]; and the Random Gap Detection Test [RGDT; Keith, 2000]). Participants underwent two 1 hr test sessions separated by at least 1 wk. Order of sessions (auditory, visual) and tests within each session were counterbalanced across participants. ANOVAs (analyses of variance) were used to examine effects of group, modality, and laterality (for the Dichotic/Dichoptic Digits tests) or response condition (for the auditory and visual Frequency Patterns and Duration Patterns tests). Pearson product-moment correlations were used to investigate relationships between auditory and visual performance. Adults performed significantly better than children on the Dichotic/Dichoptic Digits tests. Results also revealed a significant effect of modality, with auditory better than visual, and a significant modality×laterality interaction, with a right-ear advantage seen for the auditory task and a left-visual-field advantage seen for the visual task. For the Frequency Patterns test and its visual analog, results revealed a significant modality×response condition interaction, with humming better than labeling for the auditory version but the reversed effect for the visual version. For Duration Patterns testing, visual performance was significantly poorer than auditory performance. Due to poor test-retest reliability and ceiling effects for the auditory and visual gap-detection tasks, analyses could not be performed. No cross-modal correlations were observed for any test. Results demonstrated that cross-modal testing is at least feasible using easily accessible computer hardware and software. The lack of any cross-modal correlations suggests independent processing mechanisms for auditory and visual versions of each task. Examination of performance in individuals with central auditory and pan-sensory disorders is needed to determine the utility of cross-modal analogs in the differential diagnosis of (C)APD. American Academy of Audiology.
Detection of Test Collusion via Kullback-Leibler Divergence
ERIC Educational Resources Information Center
Belov, Dmitry I.
2013-01-01
The development of statistical methods for detecting test collusion is a new research direction in the area of test security. Test collusion may be described as large-scale sharing of test materials, including answers to test items. Current methods of detecting test collusion are based on statistics also used in answer-copying detection.…
Chemical analysis kit for the presence of explosives
Eckels, Joel Del [Livermore, CA; Nunes,; Peter, J [Danville, CA; Alcaraz, Armando [Livermore, CA; Whipple, Richard E [Livermore, CA
2011-05-10
A tester for testing for explosives associated with a test location comprising a first explosives detecting reagent; a first reagent holder, the first reagent holder containing the first explosives detecting reagent; a second explosives detecting reagent; a second reagent holder, the second reagent holder containing the second explosives detecting reagent; a sample collection unit for exposure to the test location, exposure to the first explosives detecting reagent, and exposure to the second explosives detecting reagent; and a body unit containing a heater for heating the sample collection unit for testing the test location for the explosives.
Rudresh, Shoorashetty Manohara; Ravi, Giriyapur Siddappa; Sunitha, Lakshminarayanappa; Hajira, Sadiya Noor; Kalaiarasan, Ellappan; Harish, Belgode Narasimha
2017-01-01
PURPOSE: Detection of carbapenemases among Gram-negative bacteria (GNB) is important for both clinicians and infection control practitioners. The Clinical and Laboratory Standards Institute recommends Carba NP (CNP) as confirmatory test for carbapenemase production. The reagents required for CNP test are costly and hence the test cannot be performed on a routine basis. The present study evaluates modifications of CNP test for rapid detection of carbapenemases among GNB. MATERIALS AND METHODS: The GNB were screened for carbapenemase production using CNP, CarbAcineto NP (CANP), and modified CNP (mCNP) test. A multiplex polymerase chain reaction (PCR) was performed on all the carbapenem-resistant bacteria for carbapenemase genes. The results of three phenotypic tests were compared with PCR. RESULTS: A total of 765 gram negative bacteria were screened for carbapenem resistance. Carbapenem resistance was found in 144 GNB. The metallo-β-lactamases were most common carbapenemases followed by OXA-48-like enzymes. The CANP test was most sensitive (80.6%) for carbapenemases detection. The mCNP test was 62.1% sensitive for detection of carbapenemases. The mCNP, CNP, and CANP tests were equally sensitive (95%) for detection of NDM enzymes among Enterobacteriaceae. The mCNP test had poor sensitivity for detection of OXA-48-like enzymes. CONCLUSION: The mCNP test was rapid, cost-effective, and easily adoptable on routine basis. The early detection of carbapenemases using mCNP test will help in preventing the spread of multidrug-resistant organisms in the hospital settings. PMID:28966495
Rudresh, Shoorashetty Manohara; Ravi, Giriyapur Siddappa; Sunitha, Lakshminarayanappa; Hajira, Sadiya Noor; Kalaiarasan, Ellappan; Harish, Belgode Narasimha
2017-01-01
Detection of carbapenemases among Gram-negative bacteria (GNB) is important for both clinicians and infection control practitioners. The Clinical and Laboratory Standards Institute recommends Carba NP (CNP) as confirmatory test for carbapenemase production. The reagents required for CNP test are costly and hence the test cannot be performed on a routine basis. The present study evaluates modifications of CNP test for rapid detection of carbapenemases among GNB. The GNB were screened for carbapenemase production using CNP, CarbAcineto NP (CANP), and modified CNP (mCNP) test. A multiplex polymerase chain reaction (PCR) was performed on all the carbapenem-resistant bacteria for carbapenemase genes. The results of three phenotypic tests were compared with PCR. A total of 765 gram negative bacteria were screened for carbapenem resistance. Carbapenem resistance was found in 144 GNB. The metallo-β-lactamases were most common carbapenemases followed by OXA-48-like enzymes. The CANP test was most sensitive (80.6%) for carbapenemases detection. The mCNP test was 62.1% sensitive for detection of carbapenemases. The mCNP, CNP, and CANP tests were equally sensitive (95%) for detection of NDM enzymes among Enterobacteriaceae. The mCNP test had poor sensitivity for detection of OXA-48-like enzymes. The mCNP test was rapid, cost-effective, and easily adoptable on routine basis. The early detection of carbapenemases using mCNP test will help in preventing the spread of multidrug-resistant organisms in the hospital settings.
10 CFR 32.103 - Schedule D-prototype tests for ice detection devices containing strontium-90.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 1 2010-01-01 2010-01-01 false Schedule D-prototype tests for ice detection devices... § 32.103 Schedule D—prototype tests for ice detection devices containing strontium-90. An applicant for a license pursuant to § 32.61 shall conduct prototype tests on each of five prototype ice detection...
10 CFR 32.103 - Schedule D-prototype tests for ice detection devices containing strontium-90.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 1 2011-01-01 2011-01-01 false Schedule D-prototype tests for ice detection devices... § 32.103 Schedule D—prototype tests for ice detection devices containing strontium-90. An applicant for a license pursuant to § 32.61 shall conduct prototype tests on each of five prototype ice detection...
10 CFR 32.103 - Schedule D-prototype tests for ice detection devices containing strontium-90.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 1 2012-01-01 2012-01-01 false Schedule D-prototype tests for ice detection devices... § 32.103 Schedule D—prototype tests for ice detection devices containing strontium-90. An applicant for a license pursuant to § 32.61 shall conduct prototype tests on each of five prototype ice detection...
NORAD's PARCS small satellite tests (1976 and 1978)
NASA Technical Reports Server (NTRS)
Kessler, D. J.
1985-01-01
NORAD sponsored small satellite tests in 1976 and 1978. The purpose of the tests was to use their more sensitive radar to determine the number of Earth orbiting objects which are not part of the official catalogue. Both tests used the PARCS radar. The characteristics of this radar are given. The detection capability of NORAD's operational system is estimated and compared to the PARC's radar sensitivity during these tests. The tests only slightly improved the detection capability, and the largest improvements were at the lowest and highest regions of its sensitivity range. The major conclusion of the test is that 17.7% of the objects detected were uncorrelated (i.e., not in the official catalogue). However, perhaps most significant is the altitutde and size distribution of detected objects are illustrated. The 1978 results are also summarized. This test concluded that at least 7% of the objects detected were not in the official catalogue. Another 6% of the detected objects were not tracked well enough to determine their status. Again, a large percentage of the detected objects at lower altitudes were not in the catalogue.
NORAD's PARCS small satellite tests (1976 and 1978)
NASA Astrophysics Data System (ADS)
Kessler, D. J.
1985-03-01
NORAD sponsored small satellite tests in 1976 and 1978. The purpose of the tests was to use their more sensitive radar to determine the number of Earth orbiting objects which are not part of the official catalogue. Both tests used the PARCS radar. The characteristics of this radar are given. The detection capability of NORAD's operational system is estimated and compared to the PARC's radar sensitivity during these tests. The tests only slightly improved the detection capability, and the largest improvements were at the lowest and highest regions of its sensitivity range. The major conclusion of the test is that 17.7% of the objects detected were uncorrelated (i.e., not in the official catalogue). However, perhaps most significant is the altitutde and size distribution of detected objects are illustrated. The 1978 results are also summarized. This test concluded that at least 7% of the objects detected were not in the official catalogue. Another 6% of the detected objects were not tracked well enough to determine their status. Again, a large percentage of the detected objects at lower altitudes were not in the catalogue.
Human anti-HIV IgM detection by the OraQuick ADVANCE® Rapid HIV 1/2 Antibody Test.
Guillon, Geraldine; Yearwood, Graham; Snipes, Casey; Boschi, Daniel; Reed, Michael R
2018-01-01
The Centers for Disease Control and Prevention (CDC) and many public health jurisdictions continue to advocate for the most sensitive rapid HIV test that is available. Currently, the recommendation is to utilize tests that can detect HIV infection biomarkers within 30 days of infection, when initial immune responses are mounted. The infected patient's IgM response is often used to detect acute infection within a 20-25 days window after infection. This requirement applies to lab-based testing with automated analyzers and rapid, point of care (POC) testing used for screening in a non-clinical setting. A recent study has demonstrated that POC tests using a Protein A-based detection system can detect samples with predominantly HIV-1 IgM reactivity (Moshgabadi et al., 2015). The OraQuick ADVANCE ® Rapid HIV-1/2 Antibody Test (OraQuick ADVANCE ®) also uses Protein A as the detection protein in the antibody-binding colloidal gold conjugate, so it is expected that the OraQuick ADVANCE ® Test will also detect samples with predominantly IgM reactivity. This report definitively demonstrates that the OraQuick ADVANCE ® Test can detect IgM antibodies during an acute infection window period of approximately 20-25 days after infection, and is therefore suitable for use in testing environments requiring adherence to current CDC recommendations.
Dasgupta, Amitava; Chughtai, Omar; Hannah, Christina; Davis, Bonnette; Wells, Alice
2004-10-01
Several adulterants are used to mask tests for abused drugs in urine. Adulterants such as "Klear" and "Whizzies" contain potassium nitrite while "Urine Luck" contains pyridinium chlorochromate (PCC). The presence of these adulterants cannot be detected by routine specimen integrity check (pH, specific gravity, creatinine and temperature). We previously reported the development of rapid spot tests to detect the presence of these adulterants. AdultaCheck 6 and Intect 7 urine test strips are commercially available for detecting the presence of these adulterants along with specific gravity, creatinine and pH in urine. The performance of these two test strips for detecting adulterants was compared with the results obtained by spot tests. Both AdultaCheck 6 and Intect 7 effectively detected the presence of nitrite and pyridinium chlorochromate in urine. Moreover, both test strips successfully detected the presence of glutaraldehyde, for which no spot test is currently available. High amount of glucose and ascorbic acid did not cause any false positive result with AdultaCheck 6 or Intect 7. Both AdultaCheck 6 and Intect 7 can be used for checking the integrity of a urine specimen submitted for drugs of abuse testing.
Gaudin, V; Hedou, C; Rault, A; Sanders, P; Verdon, E
2009-04-01
The screening of antimicrobial residues in eggs is an especially important subject. Three different commercial kits for the screening of sulphonamides and other antimicrobials in eggs were validated in accordance with Decision 2002/657/EC: one enzyme-linked immunoabsorbant assay (ELISA) kit multi-sulphonamides (from RAISIO Diagnostics) and two microbiological tests (a Premi test from DSM and an Explorer kit from Zeu-Inmunotec). The false-positive rates were lower than 2% for all kits. The detection capabilities (CCbeta) have to be as low as possible for banned substances and lower than the maximum residue limit (MRL) when MRLs have been set. The sensitivity of the Premi test was better than that of the Explorer test, probably because of the dilution of the eggs before the Explorer test was used. The CCbeta values towards most of the tested sulphonamides were satisfactory with the Premi test (< or = 100 microg kg(-1)). Performance in a proficiency test for the detection of sulphonamides in eggs with the Premi test confirmed these results. The detection capabilities of tetracycline and doxycycline were at the level of the MRL or twice the MRL maximum. The detection capabilities for chlortetracycline and oxytetracycline were higher (four to six times the MRL). The detection capabilities for amoxicillin, neomycin, tylosin and erythromycin were lower than their respective MRLs. Detection capabilities for sulphonamides were much lower for the ELISA kit than for microbiological tests. The ELISA kit could be recommended for the targeted screening of sulphonamides in eggs. On the other hand, the Explorer and Premi tests could be used as wide screening tests allowing the detection of most of the antimicrobial families.
Preparation of calibrated test packages for particle impact noise detection
NASA Technical Reports Server (NTRS)
1977-01-01
A standard calibration method for any particle impact noise detection (PIND) test system used to detect loose particles responsible for failures in hybrid circuits was developed along with a procedure for preparing PIND standard test devices. Hybrid packages were seeded with a single gold ball, hermetically sealed, leak tested, and PIND tested. Conclusions are presented.
Identification of Shifts and Trends in Hydrometric Data in Canada Based on Several Detection Tests
NASA Astrophysics Data System (ADS)
Lauzon, N.; Lence, B. J.
2004-05-01
This work proposes new detection tests based on the Kohonen neural network and on fuzzy c-means for the identification of shifts and trends in data sequences. Annual mean and maximum flow sequences are considered as application case, for they have often been considered for the study of shifts and trends in hydrologic data. In recent years, several studies for the identification of trends have been accomplished with North American hydrometric data, often making use of only one detection test. The assumption here is that one cannot rely on only one test, and consequently several are employed in this work. A total of eight tests are considered, four for shifts and four for trends. Four of these tests, two for shifts and two for trends, are conventional statistical tests that are regularly employed, while the other four are developed based on the Kohonen neural network and on fuzzy c-means. Data from a group of 40 hydrometric stations across Canada are assessed for the detection of shifts and trends in time periods of 30, 40 and 50 years. While the results obtained confirm the conclusions of previous studies performed on similar groups of data, they also indicate that each test may behave differently from one another. For example, one test may detect a trend in a given sequence while the other tests do not, or vice-versa. Thus, the strategy of using several tests ensures not only that they may confirm each others diagnostics but also may complement each other in the case of divergent diagnostics, with the possibility of improving the final conclusion on the detection of shifts and trends. Using artificial intelligence techniques for the construction of detection tests constitutes also a departure from the use of statistics, and a discussion in this work on complementary studies (i.e. detection on multivariate cases) highlights the possibility of enhanced performance by the artificial intelligence-based tests compared with conventional detection tests.
Poirel, Laurent; Fernández, Javier; Nordmann, Patrice
2016-02-01
Enterobacterial isolates producing clavulanic-inhibited extended-spectrum β-lactamases (ESBLs) are increasingly spreading in the community and are often responsible for nosocomial infections. Rapid biochemical tests have been developed recently for their detection. Three tests, namely, the Rapid ESBL NDP test, the β-Lacta test, and the Rapid ESBL Screen, have been evaluated with a collection of 108 well-characterized strains, including wild-type strains, strains producing ESBLs, overexpressed cephalosporinases, and carbapenemases. The ESBL NDP test and the Rapid ESBL Screen (a copy of the ESBL NDP test) are aimed at detecting ESBL producers, while the β-Lacta test is aimed at detecting not only ESBL producers but also cephalosporinase and carbapenemase producers. The sensitivity and specificity for detecting ESBL producers (n = 60) were 95% and 100% for the Rapid ESBL NDP test, 80% and 87% (after 30 min) and 92% and 83% (after 2 h) for the Rapid ESBL Screen, and 88% and 71% for the β-Lacta test, respectively. Varied and time-consuming detection (up to 2 h) of ESBLs by the Rapid ESBL Screen and concomitant and varied detection of producers of AmpC and several types of carbapenemases correspond to significant shortcomings of using the Rapid Screen ESBL and β-Lacta tests, respectively. Copyright © 2016, American Society for Microbiology. All Rights Reserved.
Evaluation of the White Test for the Intraoperative Detection of Bile Leakage
Leelawat, Kawin; Chaiyabutr, Kittipong; Subwongcharoen, Somboon; Treepongkaruna, Sa-ad
2012-01-01
We assess whether the White test is better than the conventional bile leakage test for the intraoperative detection of bile leakage in hepatectomized patients. This study included 30 patients who received elective liver resection. Both the conventional bile leakage test (injecting an isotonic sodium chloride solution through the cystic duct) and the White test (injecting a fat emulsion solution through the cystic duct) were carried out in the same patients. The detection of bile leakage was compared between the conventional method and the White test. A bile leak was demonstrated in 8 patients (26.7%) by the conventional method and in 19 patients (63.3%) by the White test. In addition, the White test detected a significantly higher number of bile leakage sites compared with the conventional method (Wilcoxon signed-rank test; P < 0.001). The White test is better than the conventional test for the intraoperative detection of bile leakage. Based on our study, we recommend that surgeons investigating bile leakage sites during liver resections should use the White test instead of the conventional bile leakage test. PMID:22547901
Evaluation of the white test for the intraoperative detection of bile leakage.
Leelawat, Kawin; Chaiyabutr, Kittipong; Subwongcharoen, Somboon; Treepongkaruna, Sa-Ad
2012-01-01
We assess whether the White test is better than the conventional bile leakage test for the intraoperative detection of bile leakage in hepatectomized patients. This study included 30 patients who received elective liver resection. Both the conventional bile leakage test (injecting an isotonic sodium chloride solution through the cystic duct) and the White test (injecting a fat emulsion solution through the cystic duct) were carried out in the same patients. The detection of bile leakage was compared between the conventional method and the White test. A bile leak was demonstrated in 8 patients (26.7%) by the conventional method and in 19 patients (63.3%) by the White test. In addition, the White test detected a significantly higher number of bile leakage sites compared with the conventional method (Wilcoxon signed-rank test; P < 0.001). The White test is better than the conventional test for the intraoperative detection of bile leakage. Based on our study, we recommend that surgeons investigating bile leakage sites during liver resections should use the White test instead of the conventional bile leakage test.
Statistical Requirements For Pass-Fail Testing Of Contraband Detection Systems
NASA Astrophysics Data System (ADS)
Gilliam, David M.
2011-06-01
Contraband detection systems for homeland security applications are typically tested for probability of detection (PD) and probability of false alarm (PFA) using pass-fail testing protocols. Test protocols usually require specified values for PD and PFA to be demonstrated at a specified level of statistical confidence CL. Based on a recent more theoretical treatment of this subject [1], this summary reviews the definition of CL and provides formulas and spreadsheet functions for constructing tables of general test requirements and for determining the minimum number of tests required. The formulas and tables in this article may be generally applied to many other applications of pass-fail testing, in addition to testing of contraband detection systems.
NASA Technical Reports Server (NTRS)
Hall, Steven R.; Walker, Bruce K.
1990-01-01
A new failure detection and isolation algorithm for linear dynamic systems is presented. This algorithm, the Orthogonal Series Generalized Likelihood Ratio (OSGLR) test, is based on the assumption that the failure modes of interest can be represented by truncated series expansions. This assumption leads to a failure detection algorithm with several desirable properties. Computer simulation results are presented for the detection of the failures of actuators and sensors of a C-130 aircraft. The results show that the OSGLR test generally performs as well as the GLR test in terms of time to detect a failure and is more robust to failure mode uncertainty. However, the OSGLR test is also somewhat more sensitive to modeling errors than the GLR test.
Kirkland, David; Reeve, Lesley; Gatehouse, David; Vanparys, Philippe
2011-03-18
In vitro genotoxicity testing needs to include tests in both bacterial and mammalian cells, and be able to detect gene mutations, chromosomal damage and aneuploidy. This may be achieved by a combination of the Ames test (detects gene mutations) and the in vitro micronucleus test (MNvit), since the latter detects both chromosomal aberrations and aneuploidy. In this paper we therefore present an analysis of an existing database of rodent carcinogens and a new database of in vivo genotoxins in terms of the in vitro genotoxicity tests needed to detect their in vivo activity. Published in vitro data from at least one test system (most were from the Ames test) were available for 557 carcinogens and 405 in vivo genotoxins. Because there are fewer publications on the MNvit than for other mammalian cell tests, and because the concordance between the MNvit and the in vitro chromosomal aberration (CAvit) test is so high for clastogenic activity, positive results in the CAvit test were taken as indicative of a positive result in the MNvit where there were no, or only inadequate data for the latter. Also, because Hprt and Tk loci both detect gene-mutation activity, a positive Hprt test was taken as indicative of a mouse-lymphoma Tk assay (MLA)-positive, where there were no data for the latter. Almost all of the 962 rodent carcinogens and in vivo genotoxins were detected by an in vitro battery comprising Ames+MNvit. An additional 11 carcinogens and six in vivo genotoxins would apparently be detected by the MLA, but many of these had not been tested in the MNvit or CAvit tests. Only four chemicals emerge as potentially being more readily detected in MLA than in Ames+MNvit--benzyl acetate, toluene, morphine and thiabendazole--and none of these are convincing cases to argue for the inclusion of the MLA in addition to Ames+MNvit. Thus, there is no convincing evidence that any genotoxic rodent carcinogens or in vivo genotoxins would remain undetected in an in vitro test battery consisting of Ames+MNvit. Copyright © 2011 Elsevier B.V. All rights reserved.
Wu, Zhichao; Saunders, Luke J; Daga, Fábio B; Diniz-Filho, Alberto; Medeiros, Felipe A
2017-06-01
To determine the time required to detect statistically significant progression for different rates of visual field loss using standard automated perimetry (SAP) when considering different frequencies of testing using a follow-up scheme that resembles clinical practice. Observational cohort study. One thousand seventy-two eyes of 665 patients with glaucoma followed up over an average of 4.3±0.9 years. Participants with 5 or more visual field tests over a 2- to 5-year period were included to derive the longitudinal measurement variability of SAP mean deviation (MD) using linear regressions. Estimates of variability then were used to reconstruct real-world visual field data by computer simulation to evaluate the time required to detect progression for various rates of visual field loss and different frequencies of testing. The evaluation was performed using a follow-up scheme that resembled clinical practice by requiring a set of 2 baseline tests and a confirmatory test to identify progression. Time (in years) required to detect progression. The time required to detect a statistically significant negative MD slope decreased as the frequency of testing increased, albeit not proportionally. For example, 80% of eyes with an MD loss of -2 dB/year would be detected after 3.3, 2.4, and 2.1 years when testing is performed once, twice, and thrice per year, respectively. For eyes with an MD loss of -0.5 dB/year, progression can be detected with 80% power after 7.3, 5.7, and 5.0 years, respectively. This study provides information on the time required to detect progression using MD trend analysis in glaucoma eyes when different testing frequencies are used. The smaller gains in the time to detect progression when testing is increased from twice to thrice per year suggests that obtaining 2 reliable tests at baseline followed by semiannual testing and confirmation of progression through repeat testing in the initial years of follow-up may provide a good compromise for detecting progression, while minimizing the burden on health care resources in clinical practice. Copyright © 2017 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Overseas testing of a multisensor landmine detection system: results and lessons learned
NASA Astrophysics Data System (ADS)
Keranen, Joe G.; Topolosky, Zeke
2009-05-01
The Nemesis detection system has been developed to provide an efficient and reliable unmanned, multi-sensor, groundbased platform to detect and mark landmines. The detection system consists of two detection sensor arrays: a Ground Penetrating Synthetic Aperture Radar (GPSAR) developed by Planning Systems, Inc. (PSI) and an electromagnetic induction (EMI) sensor array developed by Minelab Electronics, PTY. Limited. Under direction of the Night Vision and Electronic Sensors Directorate (NVESD), overseas testing was performed at Kampong Chhnang Test Center (KCTC), Cambodia, from May 12-30, 2008. Test objectives included: evaluation of detection performance, demonstration of real-time visualization and alarm generation, and evaluation of system operational efficiency. Testing was performed on five sensor test lanes, each consisting of a unique soil mixture and three off-road lanes which include curves, overgrowth, potholes, and non-uniform lane geometry. In this paper, we outline the test objectives, procedures, results, and lessons learned from overseas testing. We also describe the current state of the system, and plans for future enhancements and modifications including clutter rejection and feature-level fusion.
Eddy current testing for blade edge micro cracks of aircraft engine
NASA Astrophysics Data System (ADS)
Zhang, Wei-min; Xu, Min-dong; Gao, Xuan-yi; Jin, Xin; Qin, Feng
2017-10-01
Based on the problems of low detection efficiency in the micro cracks detection of aircraft engine blades, a differential excitation eddy current testing system was designed and developed. The function and the working principle of the system were described, the problems which contained the manufacture method of simulated cracks, signal generating, signal processing and the signal display method were described. The detection test was carried out by taking a certain model aircraft engine blade with simulated cracks as a tested specimen. The test data was processed by digital low-pass filter in the computer and the crack signals of time domain display and Lissajous figure display were acquired. By comparing the test results, it is verified that Lissajous figure display shows better performance compared to time domain display when the crack angle is small. The test results show that the eddy current testing system designed in this paper is feasible to detect the micro cracks on the aeroengine blade and can effectively improve the detection efficiency of micro cracks in the practical detection work.
Chaya, Dr; Parija, Subhash Chandra
2013-07-01
Cystic echinococcosis (CE) is a zoonotic disease of humans with variable clinical manifestations. Imaging and immunological methods are currently the mainstay of diagnosis of this disease. Although the immunological tests for detection of anti-echinococcal antibodies have several disadvantages, they are widely being used. Antigen is far more superior than antibody detection test as they can provide a specific parasitic diagnosis. A sandwich enzyme linked immunosorbent assay (ELISA) was designed using antibodies to 24 kDa urinary hydatid antigen for the detection of hydatid antigens in urine, serum and cyst fluid specimens. The performance of this novel test was compared with that of other hydatid antibody detection ELISA and enzyme immune transfer blot (EITB) using radiological and surgical confirmation as the gold standard. The antigen detection ELISA showed 100% sensitivity and specificity when tested with cyst fluid. On testing urine and serum, the antigen detection ELISA was found to be more specific than antibody detection ELISA. EITB was found to be the most sensitive and specific test. ELISA using polyclonal antibodies against 24 kDa urinary hydatid protein was moderately sensitive to detect hydatid antigen in serum and urine. Hence polyclonal antibodies to 24 kDa urinary hydatid antigen can be used as an alternative source of antibody to detect hydatid antigen in serum, urine and cyst fluid. In the present study, EITB was found to be highly specific test for detection of hydatid antibodiesin serum. 24 kDa protein was found to be specific and of diagnostic value in CE.
Field Test Data for Detecting Vibrations of a Building Using High-Speed Video Cameras
2017-10-01
ARL-TR-8185 ● OCT 2017 US Army Research Laboratory Field Test Data for Detecting Vibrations of a Building Using High -Speed Video...Field Test Data for Detecting Vibrations of a Building Using High -Speed Video Cameras by Caitlin P Conn and Geoffrey H Goldman Sensors and...June 2016 – October 2017 4. TITLE AND SUBTITLE Field Test Data for Detecting Vibrations of a Building Using High -Speed Video Cameras 5a. CONTRACT
Statistical Requirements For Pass-Fail Testing Of Contraband Detection Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gilliam, David M.
2011-06-01
Contraband detection systems for homeland security applications are typically tested for probability of detection (PD) and probability of false alarm (PFA) using pass-fail testing protocols. Test protocols usually require specified values for PD and PFA to be demonstrated at a specified level of statistical confidence CL. Based on a recent more theoretical treatment of this subject [1], this summary reviews the definition of CL and provides formulas and spreadsheet functions for constructing tables of general test requirements and for determining the minimum number of tests required. The formulas and tables in this article may be generally applied to many othermore » applications of pass-fail testing, in addition to testing of contraband detection systems.« less
Forsey, T; Darougar, S
1980-02-01
A rapid indirect micro-immunofluorescence test capable of detecting and differentiating type-specific antibodies to herpes simplex virus is described. The test proved highly sensitive and, in 80 patients with active herpes ocular infection, antibody was detected in 94%. No anti-herpes antibody was detected in a control group of 20 patients with adenovirus infections. Testing of animal sera prepared against herpes simplex virus types 1 and 2 and of human sera from cases of ocular and genital herpes infections showed that the test can differentiate antibodies to the infecting serotypes. Specimens of whole blood, taken by fingerprick, and eye secretions, both collected on cellulose sponges, could be tested by indirect micro-immunofluorescence. Anti-herpes IgG, IgM, and IgA can also be detected.
Lee, Kichol; Casali, John G
2017-01-01
To design a test battery and conduct a proof-of-concept experiment of a test method that can be used to measure the detection performance afforded by military advanced hearing protection devices (HPDs) and tactical communication and protective systems (TCAPS). The detection test was conducted with each of the four loudspeakers located at front, right, rear and left of the participant. Participants wore 2 in-ear-type TCAPS, 1 earmuff-type TCAPS, a passive Combat Arms Earplug in its "open" or pass-through setting and an EB-15LE™ electronic earplug. Devices with electronic gain systems were tested under two gain settings: "unity" and "max". Testing without any device (open ear) was conducted as a control. Ten participants with audiometric requirements of 25 dBHL or better at 500, 1000, 2000, 4000, 8000 Hz in both ears. Detection task performance varied with different signals and speaker locations. The test identified performance differences among certain TCAPS and protectors, and the open ear. A computer-controlled detection subtest of the Detection-Recognition/Identification-Localisation-Communication (DRILCOM) test battery was designed and implemented. Tested in a proof-of-concept experiment, it showed statistically-significant sensitivity to device differences in detection effects with the small sample of participants (10). This result has important implications for selection and deployment of TCAPS and HPDs on soldiers and workers in dynamic situations.
C. A. Clausen; S. N. Kartal
2003-01-01
Early detection of wood decay is critical because decay fungi can cause rapid structural failure. The objective of this study was to compare the sensitivity of different methods purported to detect brown-rot decay in the early stages of development. The immunodiagnostic wood decay (IWD)test, soil block test/cake pan test, mechanical property tests, and chemical...
Within-Subject Interlaboratory Variability of QuantiFERON-TB Gold In-Tube Tests
2012-09-06
QuantiFERONH-TB Gold In-Tube test (QFT-GIT) is a viable alternative to the tuberculin skin test (TST) for detecting Mycobacterium tuberculosis infection...viable alternative to the tuberculin skin test (TST) for detecting Mycobacterium tuberculosis infection. However, within-subject variability may limit test...release assays (IGRAs) are designed to detect both latent Mycobacterium tuberculosis infection (LTBI) and infections manifesting as active
ERIC Educational Resources Information Center
Cho, Sun-Joo; Preacher, Kristopher J.; Bottge, Brian A.
2015-01-01
Multilevel modeling (MLM) is frequently used to detect group differences, such as an intervention effect in a pre-test--post-test cluster-randomized design. Group differences on the post-test scores are detected by controlling for pre-test scores as a proxy variable for unobserved factors that predict future attributes. The pre-test and post-test…
Validation of antibiotic residue tests for dairy goats.
Zeng, S S; Hart, S; Escobar, E N; Tesfai, K
1998-03-01
The SNAP test, LacTek test (B-L and CEF), Charm Bacillus sterothermophilus var. calidolactis disk assay (BsDA), and Charm II Tablet Beta-lactam sequential test were validated using antibiotic-fortified and -incurred goat milk following the protocol for test kit validations of the U.S. Food and Drug Administration Center for Veterinary Medicine. SNAP, Charm BsDA, and Charm II Tablet Sequential tests were sensitive and reliable in detecting antibiotic residues in goat milk. All three assays showed greater than 90% sensitivity and specificity at tolerance and detection levels. However, caution should be taken in interpreting test results at detection levels. Because of the high sensitivity of these three tests, false-violative results could be obtained in goat milk containing antibiotic residues below the tolerance level. Goat milk testing positive by these tests must be confirmed using a more sophisticated methodology, such as high-performance liquid chromatography, before the milk is condemned. LacTek B-L test did not detect several antibiotics, including penicillin G, in goat milk at tolerance levels. However, LacTek CEF was excellent in detecting ceftiofur residue in goat milk.
The utility of six over-the-counter (home) pregnancy tests.
Cole, Laurence A
2011-08-01
The home pregnancy market is rapidly evolving. It has moved from detection of pregnancy on the day of missed menstrual bleeding, to detection claims 4 days prior. It is moving from all manual tests to digital tests, with a monitor reading the bands and informing women they are pregnant. A thorough study is needed to investigate the validity of claims and evolving usefulness of devices. Studies were proposed to examine the sensitivity and specificity of home tests and their abilities to detect pregnancy. Methods examined the abilities of tests to detect human chorionic gonadotropin (hCG), hyperglycosylated hCG, free β-subunit, a mixture of these antigens in 40 individual early pregnancy urines. Using a mixture of hCG, hyperglycosylated hCG and free β-subunit typical for early pregnancy, the sensitivity of the First Response manual and digital tests was 5.5 mIU/mL, while the sensitivities of the EPT and ClearBlue brand manual and digital tests was 22 mIU/mL. On further evaluation, the First Response manual and digital tests both detected 97% of 120 pregnancies on the day of missed menstrual bleeding. The EPT manual and digital devices detected 54% and 67% of pregnancies, respectively, and the ClearBlue manual and digital devices detected 64% and 54% of pregnancies, respectively. First Response manual and digital claim >99% detection on the day of missed menses. The results here suggest similar sensitivity for these two tests. The EPT and ClearBlue manual and digital test make similar >99% claims, the data presented here disputes their elevated claim.
Diagnostic Performance of a Molecular Test versus Clinician Assessment of Vaginitis
Gaydos, Charlotte A.; Nyirjesy, Paul; Paradis, Sonia; Kodsi, Salma; Cooper, Charles K.
2018-01-01
ABSTRACT Vaginitis is a common complaint, diagnosed either empirically or using Amsel's criteria and wet mount microscopy. This study sought to determine characteristics of an investigational test (a molecular test for vaginitis), compared to reference, for detection of bacterial vaginosis, Candida spp., and Trichomonas vaginalis. Vaginal specimens from a cross-sectional study were obtained from 1,740 women (≥18 years old), with vaginitis symptoms, during routine clinic visits (across 10 sites in the United States). Specimens were analyzed using a commercial PCR/fluorogenic probe-based investigational test that detects bacterial vaginosis, Candida spp., and Trichomonas vaginalis. Clinician diagnosis and in-clinic testing (Amsel's test, potassium hydroxide preparation, and wet mount) were also employed to detect the three vaginitis causes. All testing methods were compared to the respective reference methods (Nugent Gram stain for bacterial vaginosis, detection of the Candida gene its2, and Trichomonas vaginalis culture). The investigational test, clinician diagnosis, and in-clinic testing were compared to reference methods for bacterial vaginosis, Candida spp., and Trichomonas vaginalis. The investigational test resulted in significantly higher sensitivity and negative predictive value than clinician diagnosis or in-clinic testing. In addition, the investigational test showed a statistically higher overall percent agreement with each of the three reference methods than did clinician diagnosis or in-clinic testing. The investigational test showed significantly higher sensitivity for detecting vaginitis, involving more than one cause, than did clinician diagnosis. Taken together, these results suggest that a molecular investigational test can facilitate accurate detection of vaginitis. PMID:29643195
USDA-ARS?s Scientific Manuscript database
A simple, rapid and sensitive immunogold chromatographic strip test based on a monoclonal antibody was developed for the detection of melamine (MEL) residues in raw milk, milk products and animal feed. The limit of detection was estimated to be 0.05 µg/mL in raw milk, since the detection test line ...
Queck, Katherine E; Chapman, Angela; Herzog, Leslie J; Shell-Martin, Tamara; Burgess-Cassler, Anthony; McClure, George David
Periodontal disease in dogs is highly prevalent but can only be accurately diagnosed by performing an anesthetized oral examination with periodontal probing and dental radiography. In this study, 114 dogs had a visual awake examination of the oral cavity and were administered an oral-fluid thiol-detection test prior to undergoing a a full-mouth anesthetized oral examination and digital dental radiographs. The results show the visual awake examination underestimated the presence and severity of active periodontal disease. The thiol-detection test was superior to the visual awake examination at detecting the presence and severity of active periodontal disease and was an indicator of progression toward alveolar bone loss. The thiol-detection test detected active periodontal disease at early stages of development, before any visual cues were present, indicating the need for intervention to prevent periodontal bone loss. Early detection is important because without intervention, dogs with gingivitis (active periodontal disease) progress to irreversible periodontal bone loss (stage 2+). As suggested in the current AAHA guidelines, a thiol-detection test administered in conjunction with the visual awake examination during routine wellness examinations facilitates veterinarian-client communication and mitigates under-diagnosis of periodontal disease and underutilization of dental services. The thiol-detection test can be used to monitor the periodontal health status of the conscious patient during follow-up examinations based on disease severity.
Park, Yongjung; Kim, Beom Seok; Choi, Kyu Hun; Shin, Dong Ho; Lee, Mi Jung; Cho, Yonggeun; Kim, Hyon-Suk
2012-01-01
A novel multiplex real-time PCR assay for concurrent detection of hepatitis viruses was evaluated for its clinical performance in screening patients with acute hepatitis. A total of 648 serum samples were collected from patients with acute symptoms of hepatitis. Concurrent detection of nucleic acids of HAV, HBV and HCV was performed using the Magicplex™ HepaTrio Real-time Detection test. Serum nucleic acid levels of HBV and HCV were also quantified by the Cobas® AmpliPrep/Cobas® TaqMan® (CAP/CTM) HBV and HCV tests. Patients' medical records were also reviewed. Concordance rates between the results from the HepaTrio and the CAP/CTM tests for the detection of HBV and HCV were 94.9% (k = 0.88) and 99.2% (k = 0.98), respectively. The cycle threshold values with the HepaTrio test were also correlated well with the levels of HBV DNA (r = -0.9230) and HCV RNA (r = -0.8458). The sensitivity and specificity of the HepaTrio test were 93.8% and 98.2%, respectively, for detecting HBV infection, and 99.1% and 100.0%, respectively, for HCV infection. For the HepaTrio test, 21 (3.2%) cases were positive for both HBV and HCV. Among the positive cases, 6 (0.9%) were true coinfections. This test also detected 18 (2.8%) HAV positives. The HepaTrio test demonstrated good clinical performance and produced results that agreed well with those of the CAP/CTM assays, especially for the detection of HCV. This assay was also able to detect HAV RNA from anti-HAV IgM-positive individuals. Therefore, this new multiplex PCR assay could be useful for the concurrent detection of the three hepatitis viruses.
In-situ fault detection apparatus and method for an encased energy storing device
Hagen, Ronald A.; Comte, Christophe; Knudson, Orlin B.; Rosenthal, Brian; Rouillard, Jean
2000-01-01
An apparatus and method for detecting a breach in an electrically insulating surface of an electrically conductive power system enclosure within which a number of series connected energy storing devices are disposed. The energy storing devices disposed in the enclosure are connected to a series power connection. A detector is coupled to the series connection and detects a change of state in a test signal derived from the series connected energy storing devices. The detector detects a breach in the insulating layer of the enclosure by detecting a state change in the test signal from a nominal state to a non-nominal state. A voltage detector detects a state change of the test signals from a nominal state, represented by a voltage of a selected end energy storing device, to a non-nominal state, represented by a voltage that substantially exceeds the voltage of the selected opposing end energy storing device. Alternatively, the detector may comprise a signal generator that produces the test signal as a time-varying or modulated test signal and injects the test signal into the series connection. The detector detects the state change of the time-varying or modulated test signal from a nominal state, represented by a signal substantially equivalent to the test signal, to a non-nominal state, representative by an absence of the test signal.
Integrated Performance Testing Workshop, Modules 6 - 11
DOE Office of Scientific and Technical Information (OSTI.GOV)
Leach, Janice; Torres, Teresa M.
These modules cover performance testing of: Interior Detection Systems; Access Controls; Exterior Detection Systems; Video Assessment Systems; SNM / Contraband Detection Systems; Access Delay Elements
2007-01-01
Purpose Preschool vision screenings often include refractive error or visual acuity (VA) testing to detect amblyopia, as well as alignment testing to detect strabismus. The purpose of this study was to determine the effect of combining screening for eye alignment with screening for refractive error or reduced VA on sensitivity for detection of strabismus, with specificity set at 90% and 94%. Methods Over 3 years, 4040 preschool children were screened in the Vision in Preschoolers (VIP) Study, with different screening tests administered each year. Examinations were performed to identify children with strabismus. The best screening tests for detecting children with any targeted condition were noncycloplegic retinoscopy (NCR), Retinomax autorefractor (Right Manufacturing, Virginia Beach, VA), SureSight Vision Screener (Welch-Allyn, Inc., Skaneateles, NY), and Lea Symbols (Precision Vision, LaSalle, IL and Good-Lite Co., Elgin, IL) and HOTV optotypes VA tests. Analyses were conducted with these tests of refractive error or VA paired with the best tests for detecting strabismus (unilateral cover testing, Random Dot “E” [RDE] and Stereo Smile Test II [Stereo Optical, Inc., Chicago, IL]; and MTI PhotoScreener [PhotoScreener, Inc., Palm Beach, FL]). The change in sensitivity that resulted from combining a test of eye alignment with a test of refractive error or VA was determined with specificity set at 90% and 94%. Results Among the 4040 children, 157 were identified as having strabismus. For screening tests conducted by eye care professionals, the addition of a unilateral cover test to a test of refraction generally resulted in a statistically significant increase (range, 15%–25%) in detection of strabismus. For screening tests administered by trained lay screeners, the addition of Stereo Smile II to SureSight resulted in a statistically significant increase (21%) in sensitivity for detection of strabismus. Conclusions The most efficient and low-cost ways to achieve a statistically significant increase in sensitivity for detection of strabismus were by combining the unilateral cover test with the autorefractor (Retinomax) administered by eye care professionals and by combining Stereo Smile II with SureSight administered by trained lay screeners. The decision of whether to include a test of alignment should be based on the screening program’s goals (e.g., targeted visual conditions) and resources. PMID:17591881
Evaluation of a 'DIY' test for the detection of colorectal cancer.
Tate, J J; Northway, J; Royle, G T; Taylor, I
1989-01-01
A new type of faecal occult blood test, EZ-Detect, has been evaluated in 404 patients presenting with symptoms suggestive of colorectal disease. The test avoids handling of stools and gives a result which patients can read themselves--factors which may increase patient compliance. In comparison with the Haemoccult test, EZ-Detect has the same sensitivity for blood in laboratory conditions. In clinical use 98% of patients expressed a preference for EZ-Detect but it detected significantly fewer patients with cancer than did Haemoccult (P = less than 0.05). In its present form, this type of test would be unsuitable for population screening for colorectal cancer even if improved compliance is achieved. Images Figure 1. PMID:2585421
Conditional Tests for Localizing Trait Genes
Di, Yanming; Thompson, Elizabeth A.
2009-01-01
Background/Aims With pedigree data, genetic linkage can be detected using inheritance vector tests, which explore the discrepancy between the posterior distribution of the inheritance vectors given observed trait values and the prior distribution of the inheritance vectors. In this paper, we propose conditional inheritance vector tests for linkage localization. These conditional tests can also be used to detect additional linkage signals in the presence of previously detected causal genes. Methods For linkage localization, we propose to perform inheritance vector tests conditioning on the inheritance vectors at two positions bounding a test region. We can detect additional linkage signals by conducting a further conditional test in a region with no previously detected genes. We use randomized p values to extend the marginal and conditional tests when the inheritance vectors cannot be completely determined from genetic marker data. Results We conduct simulation studies to compare and contrast the marginal and the conditional tests and to demonstrate that randomized p values can capture both the significance and the uncertainty in the test results. Conclusions The simulation results demonstrate that the proposed conditional tests provide useful localization information, and with informative marker data, the uncertainty in randomized marginal and conditional test results is small. PMID:19439976
Mullen, Keena AE; Beasley, Erin; Rizzo, Julio Q; Washburn, Steven P; Baynes, Ronald E; Mason, Sharon E
2017-01-01
Mastitis is a costly disease for dairy farmers. Some dairy farmers use herbal products, or phytoceuticals, to treat mastitis. Phytoceuticals have not been approved for this use by the United States Food and Drug Administration, and have not been tested to determine how they impact antibiotic residue detection testing. The current study tested the potential for phytoceuticals to cause positive results on two milk antibiotic residue screening tests, the Delvotest P and Charm SL Beta-lactam test, or to interfere with the detection of antibiotics by these tests. The three phytoceuticals tested were labelled for intramammary, topical or intravulvar administration. Testing was performed in vitro using the products diluted in milk obtained from healthy organic dairy cows. Phytoceuticals were tested at concentrations ranging from 1.5 per cent to 100 per cent. Concentration levels were replicated at least twice on each milk antibiotic residue screening test. The Delvotest P is based on detection of bacterial inhibitors and no positive results were obtained for any product at concentrations less than 50 per cent. The Charm SL Beta-lactam test uses a receptor for the detection of beta-lactam antibiotics and no concentration of phytoceuticals caused an interference with these tests. Based on dilution of the products in bovine milk at physiologically achievable levels, phytoceutical products tested at levels expected after treatment do not cause positive test results for the Delvotest P nor do they interfere with the Charm SL Beta-lactam test in detection of various antibiotics. PMID:28890791
Niu, Kaili; Zheng, Xiaoping; Huang, Chusen; Xul, Kuan; Zhi, Yuan; Shen, Hebai; Jia, Nengqin
2014-07-01
An immunochromatographic test strip using gold nanoparticles-staphylococcus aureus monoclonal antibody conjugates was developed for the rapid and convenient detection of staphylococcus aureus based on a double-antibody sandwich format. The detection limit and the detection rate of this test strip is 10(3) CFU /mL and 98.7%, respectively. It could be used for the rapid detection of staphylococcus aureus in food and the results can be visually identified by the naked eye within 10 min. Compared with conventional bacterial detection methods, this developed immunochromatographic assay based test strip has several advantages including simple, fast, low-cost, favorable sensitivity and specificity, exhibiting a great potential for application in food safety control systems and clinical diagnosis.
Chaya, DR; Parija, Subhash Chandra
2013-01-01
Introduction: Cystic echinococcosis (CE) is a zoonotic disease of humans with variable clinical manifestations. Imaging and immunological methods are currently the mainstay of diagnosis of this disease. Although the immunological tests for detection of anti-echinococcal antibodies have several disadvantages, they are widely being used. Antigen is far more superior than antibody detection test as they can provide a specific parasitic diagnosis. Materials and Methods: A sandwich enzyme linked immunosorbent assay (ELISA) was designed using antibodies to 24 kDa urinary hydatid antigen for the detection of hydatid antigens in urine, serum and cyst fluid specimens. The performance of this novel test was compared with that of other hydatid antibody detection ELISA and enzyme immune transfer blot (EITB) using radiological and surgical confirmation as the gold standard. Results: The antigen detection ELISA showed 100% sensitivity and specificity when tested with cyst fluid. On testing urine and serum, the antigen detection ELISA was found to be more specific than antibody detection ELISA. EITB was found to be the most sensitive and specific test. Conclusions: ELISA using polyclonal antibodies against 24 kDa urinary hydatid protein was moderately sensitive to detect hydatid antigen in serum and urine. Hence polyclonal antibodies to 24 kDa urinary hydatid antigen can be used as an alternative source of antibody to detect hydatid antigen in serum, urine and cyst fluid. In the present study, EITB was found to be highly specific test for detection of hydatid antibodiesin serum. 24 kDa protein was found to be specific and of diagnostic value in CE. PMID:24470996
The visual detection of driving while intoxicated : field test of visual cues and detection methods
DOT National Transportation Integrated Search
1980-04-01
A Drunk Driver Detection Guide was developed and tested at a sample of 10 law enforcement agencies at locations throughout the United States. The test was designed to provide both longitudinal and cross-sectional analyses of several measures likely t...
Diagnostic Performance of a Molecular Test versus Clinician Assessment of Vaginitis.
Schwebke, Jane R; Gaydos, Charlotte A; Nyirjesy, Paul; Paradis, Sonia; Kodsi, Salma; Cooper, Charles K
2018-06-01
Vaginitis is a common complaint, diagnosed either empirically or using Amsel's criteria and wet mount microscopy. This study sought to determine characteristics of an investigational test (a molecular test for vaginitis), compared to reference, for detection of bacterial vaginosis, Candida spp., and Trichomonas vaginalis Vaginal specimens from a cross-sectional study were obtained from 1,740 women (≥18 years old), with vaginitis symptoms, during routine clinic visits (across 10 sites in the United States). Specimens were analyzed using a commercial PCR/fluorogenic probe-based investigational test that detects bacterial vaginosis, Candida spp., and Trichomonas vaginalis Clinician diagnosis and in-clinic testing (Amsel's test, potassium hydroxide preparation, and wet mount) were also employed to detect the three vaginitis causes. All testing methods were compared to the respective reference methods (Nugent Gram stain for bacterial vaginosis, detection of the Candida gene its2 , and Trichomonas vaginalis culture). The investigational test, clinician diagnosis, and in-clinic testing were compared to reference methods for bacterial vaginosis, Candida spp., and Trichomonas vaginalis The investigational test resulted in significantly higher sensitivity and negative predictive value than clinician diagnosis or in-clinic testing. In addition, the investigational test showed a statistically higher overall percent agreement with each of the three reference methods than did clinician diagnosis or in-clinic testing. The investigational test showed significantly higher sensitivity for detecting vaginitis, involving more than one cause, than did clinician diagnosis. Taken together, these results suggest that a molecular investigational test can facilitate accurate detection of vaginitis. Copyright © 2018 Schwebke et al.
Pap tests detect abnormal cervical cells, including precancerous cervical lesions, as well as early cervical cancers. HPV tests detect HPV infections that can cause cervical cell abnormalities. Learn how Pap and HPV tests are done, how often testing should be done, and how are HPV test results are reported.
A study on obstacle detection method of the frontal view using a camera on highway
NASA Astrophysics Data System (ADS)
Nguyen, Van-Quang; Park, Jeonghyeon; Seo, Changjun; Kim, Heungseob; Boo, Kwangsuck
2018-03-01
In this work, we introduce an approach to detect vehicles for driver assistance, or warning system. For driver assistance system, it must detect both lanes (left and right side lane), and discover vehicles ahead of the test vehicle. Therefore, in this study, we use a camera, it is installed on the windscreen of the test vehicle. Images from the camera are used to detect three lanes, and detect multiple vehicles. In lane detection, line detection and vanishing point estimation are used. For the vehicle detection, we combine the horizontal and vertical edge detection, the horizontal edge is used to detect the vehicle candidates, and then the vertical edge detection is used to verify the vehicle candidates. The proposed algorithm works with of 480 × 640 image frame resolution. The system was tested on the highway in Korea.
HIV resistance testing and detected drug resistance in Europe.
Schultze, Anna; Phillips, Andrew N; Paredes, Roger; Battegay, Manuel; Rockstroh, Jürgen K; Machala, Ladislav; Tomazic, Janez; Girard, Pierre M; Januskevica, Inga; Gronborg-Laut, Kamilla; Lundgren, Jens D; Cozzi-Lepri, Alessandro
2015-07-17
To describe regional differences and trends in resistance testing among individuals experiencing virological failure and the prevalence of detected resistance among those individuals who had a genotypic resistance test done following virological failure. Multinational cohort study. Individuals in EuroSIDA with virological failure (>1 RNA measurement >500 on ART after >6 months on ART) after 1997 were included. Adjusted odds ratios (aORs) for resistance testing following virological failure and aORs for the detection of resistance among those who had a test were calculated using logistic regression with generalized estimating equations. Compared to 74.2% of ART-experienced individuals in 1997, only 5.1% showed evidence of virological failure in 2012. The odds of resistance testing declined after 2004 (global P < 0.001). Resistance was detected in 77.9% of the tests, NRTI resistance being most common (70.3%), followed by NNRTI (51.6%) and protease inhibitor (46.1%) resistance. The odds of detecting resistance were lower in tests done in 1997-1998, 1999-2000 and 2009-2010, compared to those carried out in 2003-2004 (global P < 0.001). Resistance testing was less common in Eastern Europe [aOR 0.72, 95% confidence interval (CI) 0.55-0.94] compared to Southern Europe, whereas the detection of resistance given that a test was done was less common in Northern (aOR 0.29, 95% CI 0.21-0.39) and Central Eastern (aOR 0.47, 95% CI 0.29-0.76) Europe, compared to Southern Europe. Despite a concurrent decline in virological failure and testing, drug resistance was commonly detected. This suggests a selective approach to resistance testing. The regional differences identified indicate that policy aiming to minimize the emergence of resistance is of particular relevance in some European regions, notably in the countries in Eastern Europe.
Pileggi, Claudia; Flotta, Domenico; Bianco, Aida; Nobile, Carmelo G A; Pavia, Maria
2014-07-01
Human-papillomavirus (HPV) DNA testing has been proposed as an alternative to primary cervical cancer screening using cytological testing. Review of the evidence shows that available data are conflicting for some aspects. The overall goal of the study is to update the performance of HPV DNA as stand-alone testing in primary cervical cancer screening, focusing particularly on the aspects related to the specificity profile of the HPV DNA testing in respect to cytology. We performed a meta-analysis of randomized controlled clinical trials. Eight articles were included in the meta-analysis. Three outcomes have been investigated: relative detection, relative specificity, and relative positive predictive value (PPV) of HPV DNA testing versus cytology. Overall evaluation of relative detection showed a significantly higher detection of CIN2+ and CIN3+ for HPV DNA testing versus cytology. Meta-analyses that considered all age groups showed a relative specificity that favored the cytology in detecting both CIN2+ and CIN3+ lesions whereas, in the ≥30 years' group, specificity of HPV DNA and cytology tests was similar in detecting both CIN2+ and CIN3+ lesions. Results of the pooled analysis on relative PPV showed a not significantly lower PPV of HPV DNA test over cytology. A main key finding of the study is that in women aged ≥30, has been found an almost overlapping specificity between the two screening tests in detecting CIN2 and above-grade lesions. Therefore, primary screening of cervical cancer by HPV DNA testing appears to offer the right balance between maximum detection of CIN2+ and adequate specificity, if performed in the age group ≥30 years. © 2013 UICC.
Detecting Gear Tooth Fatigue Cracks in Advance of Complete Fracture
NASA Technical Reports Server (NTRS)
Zakrajsek, James J.; Lewicki, David G.
1996-01-01
Results of using vibration-based methods to detect gear tooth fatigue cracks are presented. An experimental test rig was used to fail a number of spur gear specimens through bending fatigue. The gear tooth fatigue crack in each test was initiated through a small notch in the fillet area of a tooth on the gear. The primary purpose of these tests was to verify analytical predictions of fatigue crack propagation direction and rate as a function of gear rim thickness. The vibration signal from a total of three tests was monitored and recorded for gear fault detection research. The damage consisted of complete rim fracture on the two thin rim gears and single tooth fracture on the standard full rim test gear. Vibration-based fault detection methods were applied to the vibration signal both on-line and after the tests were completed. The objectives of this effort were to identify methods capable of detecting the fatigue crack and to determine how far in advance of total failure positive detection was given. Results show that the fault detection methods failed to respond to the fatigue crack prior to complete rim fracture in the thin rim gear tests. In the standard full rim gear test all of the methods responded to the fatigue crack in advance of tooth fracture; however, only three of the methods responded to the fatigue crack in the early stages of crack propagation.
NASA Astrophysics Data System (ADS)
Zheng, Yu; Wang, Kan; Zhang, Jingjing; Qin, Weijian; Yan, Xinyu; Shen, Guangxia; Gao, Guo; Pan, Fei; Cui, Daxiang
2016-02-01
Quantum dots-labeled urea-enzyme antibody-based rapid immunochromatographic test strips have been developed as quantitative fluorescence point-of-care tests (POCTs) to detect helicobacter pylori. Presented in this study is a new test strip reader designed to run on tablet personal computers (PCs), which is portable for outdoor detection even without an alternating current (AC) power supply. A Wi-Fi module was integrated into the reader to improve its portability. Patient information was loaded by a barcode scanner, and an application designed to run on tablet PCs was developed to handle the acquired images. A vision algorithm called Kmeans was used for picture processing. Different concentrations of various human blood samples were tested to evaluate the stability and accuracy of the fabricated device. Results demonstrate that the reader can provide an easy, rapid, simultaneous, quantitative detection for helicobacter pylori. The proposed test strip reader has a lighter weight than existing detection readers, and it can run for long durations without an AC power supply, thus verifying that it possesses advantages for outdoor detection. Given its fast detection speed and high accuracy, the proposed reader combined with quantum dots-labeled test strips is suitable for POCTs and owns great potential in applications such as screening patients with infection of helicobacter pylori, etc. in near future.
Sheng, X Z; Song, J L; Zhan, W B
2012-10-01
To develop a gold immunochromatographic test strip for on-site rapid detection of lymphocystis disease virus (LCDV). Monodispersional colloidal gold and gold-labelled anti-LCDV monoclonal antibody (McAb) 2D11 were prepared and characterized by UV-visible spectroscopy and transmission electron microscopy. Gold-labelled probe was used as the detection antibody, and goat anti-mouse IgG at the control line and anti-LCDV McAb 1A8 at the test line of the test strip served as the capture antibody. The positive results could be easily judged by the presence of a red test line with naked eye within 10 min. The test strip, in good agreement with enzyme-linked immunosorbent assay and dot-blotting in sensitivity and LCDV detection, gave a detection limit of 1 μg ml(-1) of LCDV and was stable for 6 months at room temperature and 12 months at 4°C. The test strip was specific, simple and convenient for rapid detection of LCDV presenting good stability and reproducibility. This ready-to-use test strip allows on-site rapid detection of LCDV in fish without the requirement of specialized equipments and professional personnel, which could augment the practical application for diagnosis of LCDV even in disadvantage areas. © 2012 The Authors Journal of Applied Microbiology © 2012 The Society for Applied Microbiology.
9 CFR 113.34 - Detection of hemagglutinating viruses.
Code of Federal Regulations, 2011 CFR
2011-01-01
... REQUIREMENTS Standard Procedures § 113.34 Detection of hemagglutinating viruses. The test for detection of hemagglutinating viruses provided in this section shall be conducted when such a test is prescribed in an... with Newcastle Disease Vaccine, test samples shall be collected from bulk suspensions of each prior to...
9 CFR 113.34 - Detection of hemagglutinating viruses.
Code of Federal Regulations, 2012 CFR
2012-01-01
... REQUIREMENTS Standard Procedures § 113.34 Detection of hemagglutinating viruses. The test for detection of hemagglutinating viruses provided in this section shall be conducted when such a test is prescribed in an... with Newcastle Disease Vaccine, test samples shall be collected from bulk suspensions of each prior to...
9 CFR 113.34 - Detection of hemagglutinating viruses.
Code of Federal Regulations, 2010 CFR
2010-01-01
... REQUIREMENTS Standard Procedures § 113.34 Detection of hemagglutinating viruses. The test for detection of hemagglutinating viruses provided in this section shall be conducted when such a test is prescribed in an... with Newcastle Disease Vaccine, test samples shall be collected from bulk suspensions of each prior to...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-13
...] Draft Guidelines on Biologics Quality Monitoring: Testing for the Detection of Mycoplasma Contamination... Detection of Mycoplasma Contamination.'' This draft guideline identifies stages of manufacture where... contamination. Because the guidelines apply to final product and master seed/cell testing in veterinary vaccines...
The detection error of thermal test low-frequency cable based on M sequence correlation algorithm
NASA Astrophysics Data System (ADS)
Wu, Dongliang; Ge, Zheyang; Tong, Xin; Du, Chunlin
2018-04-01
The problem of low accuracy and low efficiency of off-line detecting on thermal test low-frequency cable faults could be solved by designing a cable fault detection system, based on FPGA export M sequence code(Linear feedback shift register sequence) as pulse signal source. The design principle of SSTDR (Spread spectrum time-domain reflectometry) reflection method and hardware on-line monitoring setup figure is discussed in this paper. Testing data show that, this detection error increases with fault location of thermal test low-frequency cable.
Improved wheal detection from skin prick test images
NASA Astrophysics Data System (ADS)
Bulan, Orhan
2014-03-01
Skin prick test is a commonly used method for diagnosis of allergic diseases (e.g., pollen allergy, food allergy, etc.) in allergy clinics. The results of this test are erythema and wheal provoked on the skin where the test is applied. The sensitivity of the patient against a specific allergen is determined by the physical size of the wheal, which can be estimated from images captured by digital cameras. Accurate wheal detection from these images is an important step for precise estimation of wheal size. In this paper, we propose a method for improved wheal detection on prick test images captured by digital cameras. Our method operates by first localizing the test region by detecting calibration marks drawn on the skin. The luminance variation across the localized region is eliminated by applying a color transformation from RGB to YCbCr and discarding the luminance channel. We enhance the contrast of the captured images for the purpose of wheal detection by performing principal component analysis on the blue-difference (Cb) and red-difference (Cr) color channels. We finally, perform morphological operations on the contrast enhanced image to detect the wheal on the image plane. Our experiments performed on images acquired from 36 different patients show the efficiency of the proposed method for wheal detection from skin prick test images captured in an uncontrolled environment.
Tsumura, Yukari; Ishimitsu, Susumu; Otaki, Kayo; Uchimi, Hiroyuki; Matsumoto, Nobuyuki; Daba, Masaki; Tsuchiya, Tetsu; Ukyo, Masaho; Tonogai, Yasuhide
2003-10-01
An experimental proficiency test program for ability to screen 104 residual pesticides in agricultural products has been conducted. Eight Japanese laboratories joined the program. Items tested in the present study were limit of detection, internal proficiency test (self spike) and external proficiency test (blind spike). All 104 pesticides were well detected and recovered from agricultural foods in the internal proficiency test. However, the results of the external proficiency test did not completely agree with those of the internal proficiency tests. After 5 rounds of the blind spike test, the ratio of the number of correctly detected pesticides to that of actually contained ones (49 total) ranged from 65% to 100% among laboratories. The numbers of mistakenly detected pesticides by a laboratory were 0 to 15. Thus, there was a great difference among the laboratories in the ability to screen multiresidual pesticides.
PERFORMANCE EVALUATION OF A PROTOTYPE ARCHITECT ANTIBODY ASSAY FOR BABESIA MICROTI.
Cheng, Kevin; Coller, Kelly E; Marohnic, Christopher C; Pfeiffer, Zachary A; Fino, James R; Elsing, Randee R; Bergsma, Janet; Marcinkus, Marilee A; Kar, Alak K; Gumbs, Orlando H; Otis, Kathy S; Fishpaugh, Jeffrey; Schultz, Phillip W; Pope, Mark R; Narvaez, Alfredo R; Wong, Susan J; Madison-Antenucci, Susan; Leary, Thomas P; Dawson, George J
2018-05-09
The tick-borne protozoan Babesia microti is responsible for more than 200 cases of transfusion-transmitted babesiosis (TTB) infection in the United States over the last 30 years. Measures to mitigate the risk of TTB include nucleic acid testing (NAT) and B. microti antibody testing. A fully automated prototype B. microti antibody test was developed on the ARCHITECT instrument. The specificity was determined to be 99.98% in volunteer blood donors (n=28,740) from areas considered as low endemic for B. microti The sensitivity of the prototype test was studied in experimentally-infected macaques; a total of 128 samples were detected compared to 125 with the indirect fluorescent antibody test (IFA), additionally, 83 (89.2%) of the PCR positive samples were detected compared to 81 (87.1%) using the IFA test. All PCR positive samples that tested negative in the prototype antibody test were pre-seroconversion period samples. Following seroconversion, periods of intermittent parasitemia occurred; 17 PCR negative samples drawn in-between PCR positive bleed dates, tested positive both by the prototype test (robust reactivity) and IFA (marginal reactivity) prior to the administration of therapeutic drugs, indicating that the PCR test failed to detect samples from persistently infected macaques. The prototype assay detected 56 of 58 (96.6%) human subjects diagnosed with clinical babesiosis by both PCR and IFA testing. Overall, the prototype anti-babesia assay provides a highly sensitive and specific test for the diagnosis of B. microti infection. While PCR is preferred for detection of window period parasitemia, antibody tests detect infected subjects during periods of low level parasitemia. Copyright © 2018 Cheng et al.
Pasteran, Fernando; Gonzalez, Lisandro J.; Albornoz, Ezequiel; Bahr, Guillermo; Vila, Alejandro J.
2015-01-01
Accurate detection of carbapenemase-producing Gram-negative bacilli is of utmost importance for the control of nosocomial spread and the initiation of appropriate antimicrobial therapy. The modified Hodge test (MHT), a carbapenem inactivation assay, has shown poor sensitivity in detecting the worldwide spread of New Delhi metallo-β-lactamase (NDM). Recent studies demonstrated that NDM is a lipoprotein anchored to the outer membrane in Gram-negative bacteria, unlike all other known carbapenemases. Here we report that membrane anchoring of β-lactamases precludes detection of carbapenemase activity by the MHT. We also show that this limitation can be overcome by the addition of Triton X-100 during the test, which allows detection of NDM. We propose an improved version of the assay, called the Triton Hodge test (THT), which allows detection of membrane-bound carbapenemases with the addition of this nonionic surfactant. This test was challenged with a panel of 185 clinical isolates (145 carrying known carbapenemase-encoding genes and 40 carbapenemase nonproducers). The THT displayed test sensitivity of >90% against NDM-producing clinical isolates, while improving performance against other carbapenemases. Ertapenem provided the highest sensitivity (97 to 100%, depending on the type of carbapenemase), followed by meropenem (92.5 to 100%). Test specificity was not affected by the addition of Triton (87.5% and 92.5% with ertapenem and meropenem, respectively). This simple inexpensive test confers a large improvement to the sensitivity of the MHT for the detection of NDM and other carbapenemases. PMID:26719442
Hagvall, Lina; Karlberg, Ann-Therese; Christensson, Johanna B
2013-04-01
Geraniol is a commonly used fragrance terpene, and is tested in the baseline series in fragrance mix I. Geraniol is a pro-hapten and a pre-hapten, and sensitizers are formed in the autoxidation and skin metabolism of geraniol. Previous patch testing with air-exposed (oxidized) geraniol has suggested that oxidized geraniol could be a better marker for contact allergy to geraniol than pure geraniol. To find the optimal patch test substance and concentration for detecting contact allergy to geraniol. Six hundred and fifty-five patients were patch tested with pure and oxidized geraniol at 4.0%, 6.0% and 11.0% in petrolatum. Before patch testing, the irritant properties of pure and oxidized geraniol were studied in 27 patients at 2.5%, 5.0%, 10.0% and 20.0% pet. Pure geraniol detected positive reactions in 0.15-1.1% of the patients, and oxidized geraniol detected positive reactions in 0.92-4.6% of the patients. Reactions to pure geraniol in patients not reacting to oxidized geraniol indicated metabolic activation of geraniol. Neither pure nor oxidized geraniol gave significant irritant reactions. Increasing the test concentrations of pure and oxidized geraniol enables the detection of more cases of contact allergy. Oxidized geraniol detects more patients than pure geraniol, but patch testing with only oxidized geraniol does not detect all cases of contact allergy to geraniol. © 2013 John Wiley & Sons A/S.
Heinrichs, A; Huang, T D; Berhin, C; Bogaerts, P; Glupczynski, Y
2015-07-01
The purpose of this investigation was to compare several phenotypic methods, including combined disk tests (CDT) containing metallo-β-lactamase (MBL) inhibitors or cloxacillin, and the Carba NP test for the detection of carbapenemase-producing Pseudomonas aeruginosa (CPPA). A new CDT using imipenem (10 μg) ± cloxacillin 4,000 μg and the Carba NP test were evaluated to detect CPPA. In addition, four commercially available combined disks containing a carbapenem and ethylene-diamine-tetra-acetic acid (EDTA) or dipicolinic acid (DPA) as the inhibitor were tested in order to detect MBL-positive P. aeruginosa. All these phenotypic methods were evaluated on 188 imipenem non-susceptible P. aeruginosa (CPPA, n = 75) isolates divided into 26 well-characterized collection strains and 162 non-duplicate clinical isolates referred to the national reference laboratory in 2013. For the total of 188 isolates tested, CDT containing EDTA or DPA displayed high sensitivities (99%) and specificities (95%) for detecting MBL-producing isolates. CDT with cloxacillin showed a sensitivity and specificity of 97%/96% compared to 88%/99% for the Carba NP test in order to detect CPPA. For the 162 clinical isolates, CDT containing EDTA or DPA displayed a high negative predictive value (NPV) (99%) for detecting MBL-producing isolates. CDT with cloxacillin showed an NPV of 98%, compared to 95% for the Carba NP test in order to detect CPPA. In our setting, CDT associating imipenem ± EDTA or ± DPA performed best for the detection of MBL-producing P. aeruginosa. Imipenem/imipenem-cloxacillin test yielded good NPV to exclude the presence of MBL in imipenem non-susceptible isolates.
Elsafi, Salah H; Alqahtani, Norah I; Zakary, Nawaf Y; Al Zahrani, Eidan M
2015-01-01
To study the performance of a single test using two fecal occult blood tests with colonoscopy for the detection of colorectal cancer (CRC) for the first time in Saudi Arabia to determine possible implications for the anticipated colorectal screening program. We compared the performance of guaiac and immunochemical fecal occult blood tests for the detection of CRC among patients of 50-74 years old attending two hospitals in the Eastern Region of Saudi Arabia. Samples of feces were collected from 257 asymptomatic patients and 20 cases of confirmed CRC, and they were tested simultaneously by the guaiac-based occult blood test and monoclonal antibody-based immunoassay kit. Colonoscopy was performed on all participants and the results were statistically analyzed with both positive and negative occult blood tests of both methods. Of the 277 subjects, 79 tested positive for occult blood with at least one method. Overall, the number of those with an occult blood-positive result by both tests was 39 (14.1%), while for 198 (71.5%), both tests were negative (P<0.0001); 40 (14.4%) samples showed a discrepant result. Colonoscopy data were obtained for all 277 patients. A total of three invasive cancers were detected among the screening group. Of the three, the guaiac test detected two cases, while the immunochemical test detected three of them. Of the 20 control cases, the guaiac test detected 13 CRC cases (P=0.03), while the immunochemical test detected 16 of them (P<0.0001). The sensitivity of guaiac and immunochemical tests for the detection of CRC in the screening group was 50.00% (95% confidence interval [CI] =6.76-93.24) and 75.00% (95% CI =19.41-99.37), respectively. For comparison, the sensitivity of the guaiac fecal occult blood test for detecting CRC among the control group was 65.00% (95% CI =40.78-84.61) while that of FIT was 80.00% (95% CI =56.34-94.27). The specificity of the guaiac and immunoassay tests was 77.87% (95% CI =72.24-82.83) and 90.12% (95% CI =85.76-93.50), respectively. The positive likelihood ratio of guaiac and immunochemical tests for the detection of CRC was 2.26 (95% CI =0.83-6.18) and 7.59 (95% CI =3.86-14.94), whereas the negative likelihood ratio was 0.64 (95% CI =0.24-1.71) and 0.28 (95% CI =0.05-1.52), respectively. The positive predictive values of guaiac and immunochemical tests were 3.45% (95% CI =0.426-11.91) and 10.71% (95% CI =2.27-28.23), respectively. There was no marked difference in the negative predictive values for both methods. The sensitivity of the fecal occult blood test by FIT was significantly higher for stages III and IV colorectal cancer than for stages I and II (P=0.01) and it was insignificant for the guaiac fecal occult blood test (P=0.07). In areas where other advance screening methods of CRC are not feasible, the use of FIT can be considered.
Method modification of the Legipid® Legionella fast detection test kit.
Albalat, Guillermo Rodríguez; Broch, Begoña Bedrina; Bono, Marisa Jiménez
2014-01-01
Legipid(®) Legionella Fast Detection is a test based on combined magnetic immunocapture and enzyme-immunoassay (CEIA) for the detection of Legionella in water. The test is based on the use of anti-Legionella antibodies immobilized on magnetic microspheres. Target microorganism is preconcentrated by filtration. Immunomagnetic analysis is applied on these preconcentrated water samples in a final test portion of 9 mL. The test kit was certified by the AOAC Research Institute as Performance Tested Method(SM) (PTM) No. 111101 in a PTM validation which certifies the performance claims of the test method in comparison to the ISO reference method 11731-1998 and the revision 11731-2004 "Water Quality: Detection and Enumeration of Legionella pneumophila" in potable water, industrial water, and waste water. The modification of this test kit has been approved. The modification includes increasing the target analyte from L. pneumophila to Legionella species and adding an optical reader to the test method. In this study, 71 strains of Legionella spp. other than L. pneumophila were tested to determine its reactivity with the kit based on CEIA. All the strains of Legionella spp. tested by the CEIA test were confirmed positive by reference standard method ISO 11731. This test (PTM 111101) has been modified to include a final optical reading. A methods comparison study was conducted to demonstrate the equivalence of this modification to the reference culture method. Two water matrixes were analyzed. Results show no statistically detectable difference between the test method and the reference culture method for the enumeration of Legionella spp. The relative level of detection was 93 CFU/volume examined (LOD50). For optical reading, the LOD was 40 CFU/volume examined and the LOQ was 60 CFU/volume examined. Results showed that the test Legipid Legionella Fast Detection is equivalent to the reference culture method for the enumeration of Legionella spp.
An Improved Extended-Spectrum-β-Lactamase Detection Test Utilizing Aztreonam plus Clavulanate.
Thomson, Gina K; Ayaz, Maaz; Lutes, Kelli; Thomson, Kenneth S
2018-01-01
Clinical laboratories test for extended-spectrum β-lactamases (ESBLs) for epidemiological and infection control purposes and also for the potential of cephalosporins to cause therapeutic failures. Testing can be problematic, because the CLSI does not recommend the testing of all producers of ESBLs and also falsely negative results may occur with isolates that coproduce AmpC. Boronic acid-supplemented tests can enhance ESBL detection in AmpC producers. Because aztreonam inhibits AmpCs, a study was designed to compare ESBL detection by the CLSI disk test (CLSI), a boronic acid-supplemented CLSI disk test (CLSI plus BA), and an aztreonam plus clavulanate disk test (ATM plus CA). The study tested 100 well-characterized Enterobacteriaceae , Acinetobacter baumannii , and Pseudomonas aeruginosa isolates. Seventy produced TEM, SHV, or CTX-M ESBLs, with 15 coproducing an AmpC and 11 coproducing a metallo-β-lactamase. Thirty ESBL-negative isolates were also tested. Tests were inoculated by CLSI methodology and interpreted as positive if an inhibitor caused a zone diameter increase of ≥5 mm. The percentages of ESBL producers detected were as follows: ATM plus CA, 95.7%; CLSI plus BA, 88.6%; and CLSI, 78.6%. When AmpC was coproduced, the sensitivities of the tests were as follows: ATM plus CA, 100%; CLSI plus BA, 93.3%; and CLSI, 60%. ATM plus CA also detected an ESBL in 90.1% of isolates that coproduced a metallo-β-lactamase. Falsely positive tests occurred only with the CLSI and CLSI plus BA tests. Overall, the ATM plus CA test detected ESBLs more accurately than the CLSI and CLSI plus BA tests, especially with isolates coproducing an AmpC or metallo-β-lactamase. Copyright © 2017 American Society for Microbiology.
Wan Nor Amilah, W A W; Noor Izani, N J; Ng, W K; Ashraful Haq, J
2012-12-01
Clinical utilization of carbapenems remains under threat with the emergence of acquired carbapenemase-producing bacteria, particularly metallo-β-lactamases (MBL). Rapid detection of MBL-producing Gram-negative bacilli is essential to prevent their widespread dissemination. However, no standardized detection method is available for routine laboratory use. The purpose of the study was to evaluate a chelating-agent based double disk synergic test and disk potentiation test for MBL-producing strain detection and to determine the isolation rate of MBL-producing Pseudomonas aeruginosa and Acinetobacter from clinical samples in our tertiary teaching hospital. A total of 22 and 66 imipenem-resistant P. aeruginosa and Acinetobacter isolates respectively were tested with ceftazidime (CAZ) disk by modified double disk synergic test and disk potentiation test using ethylenediaminetetraacetic acid (EDTA) and 2-mercaptopropionic acid (as chelating agents) to detect MBL production. The tests were compared with EDTA-phenanthroline-imipenem (EPI) microdilution MIC test as gold standard. MBL positive strains were detected in 17 (77.3%) P. aeruginosa and 2 (3.5%) Acinetobacter isolates. The disk potentiation test with 2-mercaptopropionic acid (2-MPA) dilution of 1:12 provided the most acceptable sensitivities and specificities (88.2% sensitivity and 100% specificity in P. aeruginosa; 100% sensitivity and specificity in Acinetobacter) compared to other screening methods used in this study. This study provided useful information on the local prevalence of MBL-producing P. aeruginosa and Acinetobacter in our hospital. Disc potentiation test with CAZ/2-MPA disc appears to be reliable and convenient MBL detection method in the routine clinical laboratory.
Dry-Enzyme Test For Gaseous Chemicals
NASA Technical Reports Server (NTRS)
Barzana, Eduardo; Karel, Marcus; Klibanov, Alexander
1990-01-01
Simple, dry-chemical test detects ethanol in human breath. Method of test also adapted to detection of such toxic chemicals as formaldehyde in airstreams. Used qualitatively to detect chemical compounds above present level; for example, ethanol above legal level for driving. Also used to indicate quantitatively concentrations of compounds. Involves dry enzyme and color indicator. Adapted to detect any gaseous compound transformed by enzymes to produce change evident to human eye or to instrument.
Power of tests of normality for detecting contaminated normal samples
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thode, H.C. Jr.; Smith, L.A.; Finch, S.J.
1981-01-01
Seventeen tests of normality or goodness of fit were evaluated for power at detecting a contaminated normal sample. This study used 1000 replications each of samples of size 12, 17, 25, 33, 50, and 100 from six different contaminated normal distributions. The kurtosis test was the most powerful over all sample sizes and contaminations. The Hogg and weighted Kolmogorov-Smirnov tests were second. The Kolmogorov-Smirnov, chi-squared, Anderson-Darling, and Cramer-von-Mises tests had very low power at detecting contaminated normal random variables. Tables of the power of the tests and the power curves of certain tests are given.
9 CFR 113.36 - Detection of pathogens by the chicken inoculation test.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Detection of pathogens by the chicken... REQUIREMENTS Standard Procedures § 113.36 Detection of pathogens by the chicken inoculation test. The test for...,000 doses. (b) At least 25 healthy susceptible young chickens, properly identified and obtained from...
How to detect carbapenemase producers? A literature review of phenotypic and molecular methods.
Hammoudi, D; Moubareck, C Ayoub; Sarkis, D Karam
2014-12-01
This review describes the current state-of-art of carbapenemase detection methods. Identification of carbapenemases is first based on conventional phenotypic tests including antimicrobial susceptibility testing, modified-Hodge test and carbapenemase-inhibitor culture tests. Second, molecular characterization of carbapenemase genes by PCR sequencing is essential. Third, innovative biochemical and spectrometric detection may be applied. Copyright © 2014 Elsevier B.V. All rights reserved.
Engler, K. H.; Efstratiou, A.; Norn, D.; Kozlov, R. S.; Selga, I.; Glushkevich, T. G.; Tam, M.; Melnikov, V. G.; Mazurova, I. K.; Kim, V. E.; Tseneva, G. Y.; Titov, L. P.; George, R. C.
2002-01-01
An immunochromatographic strip (ICS) test was developed for the detection of diphtheria toxin by using an equine polyclonal antibody as the capture antibody and colloidal gold-labeled monoclonal antibodies specific for fragment A of the diphtheria toxin molecule as the detection antibody. The ICS test has been fully optimized for the detection of toxin from bacterial cultures; the limit of detection was approximately 0.5 ng of diphtheria toxin per ml within 10 min. In a comparative study with 915 pure clinical isolates of Corynebacterium spp., the results of the ICS test were in complete agreement with those of the conventional Elek test. The ICS test was also evaluated for its ability to detect toxigenicity from clinical specimens (throat swabs) in two field studies conducted within areas of the former USSR where diphtheria is epidemic. Eight hundred fifty throat swabs were examined by conventional culture and by use of directly inoculated broth cultures for the ICS test. The results showed 99% concordance (848 of 850 specimens), and the sensitivity and specificity of the ICS test were 98% (95% confidence interval, 91 to 99%) and 99% (95% confidence interval, 99 to 100%), respectively. PMID:11773096
Wright, David M; Allen, Adrian R; Mallon, Thomas R; McDowell, Stanley W J; Bishop, Stephen C; Glass, Elizabeth J; Bermingham, Mairead L; Woolliams, John A; Skuce, Robin A
2013-10-01
Strains of many infectious diseases differ in parameters that influence epidemic spread, for example virulence, transmissibility, detectability and host specificity. Knowledge of inter-strain variation can be exploited to improve management and decrease disease incidence. Bovine tuberculosis (bTB) is increasingly prevalent among farmed cattle in the UK, exerting a heavy economic burden on the farming industry and government. We aimed to determine whether strains of Mycobacterium bovis (the causative agent of bTB) identified and classified using genetic markers (spoligotyping and multi-locus VNTR analysis) varied in response to the tuberculin skin test; this being the primary method of bTB detection used in the UK. Inter-strain variation in detectability of M. bovis could have important implications for disease control. The skin test is based on a differential delayed type hypersensitivity (DTH) response to intradermal injections of purified protein derivative (PPD) from M. bovis (PPD-B) and Mycobacterium avium (PPD-A). We searched for an association between skin test response (PPD-B skin rise minus PPD-A skin rise) and M. bovis genotype at the disclosing test in culture-confirmed cases using a field dataset consisting of 21,000 isolates belonging to 63 genotypes of M. bovis from cattle in Northern Ireland. We found no substantial variation among genotypes (estimated responses clustered tightly around the mean) controlling for animal sex, breed and test effects. We also estimated the ratio of skin test detected to undetected cases (i.e. cases only detected at abattoir). The skin test detection ratio varied among abattoirs with some detecting a greater proportion of cases than others but this variation was unrelated to the community composition of genotypes within each abattoir catchment. These two lines of evidence indicate that M. bovis genotypes in Northern Ireland have similar detectability using the skin test. Crown Copyright © 2013. Published by Elsevier B.V. All rights reserved.
Detection of new HIV infections in a multicentre HIV antiretroviral pre-exposure prophylaxis trial.
Fransen, Katrien; de Baetselier, Irith; Rammutla, Elizabeth; Ahmed, Khatija; Owino, Frederick; Agingu, Walter; Venter, Gustav; Deese, Jen; Van Damme, Lut; Crucitti, Tania
2017-08-01
Monthly specimens collected from FEM-PrEP-a Phase III trial [1] were investigated for the detection of acute HIV (AHI) infection. To evaluate the efficiency of the study-specific HIV algorithm in detecting AHI, and the performance of each of the serological and molecular tests used in diagnosing new infections, and their contribution to narrowing the window period. A total of 83 pre-seroconversion specimens from 61 seroconverters from the FEM-PrEP trial were further analyzed in a sub-study. During the trial, HIV seroconversion was diagnosed on site using a testing algorithm with simple/rapid tests (SRTs) and confirmed with a gold standard testing algorithm (see short communication: Fig. 1). The infection date was determined more accurately by the use of standard ELISAs and Nucleic Acid Amplification Tests (NAAT) in a look-back procedure. For this sub-study, the international central laboratory repeated the study algorithm using SRTs. A total of 83 pre-seroconversions specimens from 61 seroconverters were analyzed in a look-back procedure. RNA was detected in 35/61 seroconverters at the visit before the seroconversion visit as determined at the study sites. Four seroconversion dates were inaccurate at one study site as the international central laboratory detected the HIV infection one visit earlier using the same test algorithm. Using the gold standard, an additional seroconversion was detected at an earlier visit. The combined antigen/antibody and the single antigen test had a higher sensitivity compared to the SRTs in detecting acute infections. In the FEM-PrEP trial, the international central laboratory detected a small number of seroconversions one month earlier than the study sites using the same study algorithm. Standard tests are still the most sensitive tests in detecting pre-seroconversion or acute HIV infection, but they are costly, time consuming and not recommended for use on-site in a clinical trial. Copyright © 2017 Elsevier B.V. All rights reserved.
[Variations in the diagnostic confirmation process between breast cancer mass screening units].
Natal, Carmen; Fernández-Somoano, Ana; Torá-Rocamora, Isabel; Tardón, Adonina; Castells, Xavier
2016-01-01
To analyse variations in the diagnostic confirmation process between screening units, variations in the outcome of each episode and the relationship between the use of the different diagnostic confirmation tests and the lesion detection rate. Observational study of variability of the standardised use of diagnostic and lesion detection tests in 34 breast cancer mass screening units participating in early-detection programmes in three Spanish regions from 2002-2011. The diagnostic test variation ratio in percentiles 25-75 ranged from 1.68 (further appointments) to 3.39 (fine-needle aspiration). The variation ratio in detection rates of benign lesions, ductal carcinoma in situ and invasive cancer were 2.79, 1.99 and 1.36, respectively. A positive relationship between rates of testing and detection rates was found with fine-needle aspiration-benign lesions (R(2): 0.53), fine-needle aspiration-invasive carcinoma (R(2): 0 28), core biopsy-benign lesions (R(2): 0.64), core biopsy-ductal carcinoma in situ (R(2): 0.61) and core biopsy-invasive carcinoma (R(2): 0.48). Variation in the use of invasive tests between the breast cancer screening units participating in early-detection programmes was found to be significantly higher than variations in lesion detection. Units which conducted more fine-needle aspiration tests had higher benign lesion detection rates, while units that conducted more core biopsies detected more benign lesions and cancer. Copyright © 2016 SESPAS. Published by Elsevier Espana. All rights reserved.
9 CFR 113.30 - Detection of Salmonella contamination.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Detection of Salmonella contamination... REQUIREMENTS Standard Procedures § 113.30 Detection of Salmonella contamination. The test for detection of Salmonella contamination provided in this section shall be conducted when such a test is prescribed in an...
9 CFR 113.30 - Detection of Salmonella contamination.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 9 Animals and Animal Products 1 2011-01-01 2011-01-01 false Detection of Salmonella contamination... REQUIREMENTS Standard Procedures § 113.30 Detection of Salmonella contamination. The test for detection of Salmonella contamination provided in this section shall be conducted when such a test is prescribed in an...
Chemical contamination remote sensing
NASA Technical Reports Server (NTRS)
Carrico, J. P.; Phelps, K. R.; Webb, E. N.; Mackay, R. A.; Murray, E. R.
1986-01-01
A ground mobile laser test bed system was assembled to assess the feasibility of detection of various types of chemical contamination using Differential Scattering (DISC) and Differential Absorption (DIAL) Lidar techniques. Field experiments with the test bed system using chemical simulants were performed. Topographic reflection and range resolved DIAL detection of vapors as well as DISC detection of aerosols and surface contamination were achieved. Review of detection principles, design of the test bed system, and results of the experiments are discussed.
Pasteran, Fernando; Gonzalez, Lisandro J; Albornoz, Ezequiel; Bahr, Guillermo; Vila, Alejandro J; Corso, Alejandra
2016-03-01
Accurate detection of carbapenemase-producing Gram-negative bacilli is of utmost importance for the control of nosocomial spread and the initiation of appropriate antimicrobial therapy. The modified Hodge test (MHT), a carbapenem inactivation assay, has shown poor sensitivity in detecting the worldwide spread of New Delhi metallo-β-lactamase (NDM). Recent studies demonstrated that NDM is a lipoprotein anchored to the outer membrane in Gram-negative bacteria, unlike all other known carbapenemases. Here we report that membrane anchoring of β-lactamases precludes detection of carbapenemase activity by the MHT. We also show that this limitation can be overcome by the addition of Triton X-100 during the test, which allows detection of NDM. We propose an improved version of the assay, called the Triton Hodge test (THT), which allows detection of membrane-bound carbapenemases with the addition of this nonionic surfactant. This test was challenged with a panel of 185 clinical isolates (145 carrying known carbapenemase-encoding genes and 40 carbapenemase nonproducers). The THT displayed test sensitivity of >90% against NDM-producing clinical isolates, while improving performance against other carbapenemases. Ertapenem provided the highest sensitivity (97 to 100%, depending on the type of carbapenemase), followed by meropenem (92.5 to 100%). Test specificity was not affected by the addition of Triton (87.5% and 92.5% with ertapenem and meropenem, respectively). This simple inexpensive test confers a large improvement to the sensitivity of the MHT for the detection of NDM and other carbapenemases. Copyright © 2016, American Society for Microbiology. All Rights Reserved.
Helicobacter pylori diagnostic tests in children: review of the literature from 1999 to 2009.
Guarner, Jeannette; Kalach, Nicolas; Elitsur, Yoram; Koletzko, Sibylle
2010-01-01
The array of tests that can be used for diagnosis of Helicobacter pylori infection is large, and it can be confusing to define which test to use particularly in children where results may not be comparable to those obtained in adult patients. Using PubMed, we reviewed the English literature from January 1999 to May 2009 to identify articles that determined sensitivity and specificity of H. pylori invasive and non-invasive diagnostic tests in children. We excluded articles that presented a review of the literature, abstracts, case reports, or series where children's results could not be separated from adult populations. Of the tissue based methods, rapid urease tests have better sensitivity than histology to detect presence of H. pylori; however, histology can detect the pathology associated with disease including gastritis, intestinal metaplasia, and other conditions that could be the cause of the child's symptoms. Culture of gastric tissues or stool has 100% specificity but sensitivity is low. Of the serologic tests, immunoblot has the best sensitivity. The urea breath tests have >75% sensitivity for detection of H. pylori before and after treatment. Immunoassays in stool using monoclonal antibodies have >95% sensitivity for detection of H. pylori before and after treatment. PCR testing can be performed in tissue and stool samples and can detect genes associated to antibiotic resistance. In summary, the current commercial non-invasive tests have adequate sensitivity and specificity for detecting the presence of H. pylori; however, endoscopy with histopathology is the only method that can detect H. pylori and lesions associated with the infection.
Shi, Xiaoping; Wu, Yuehua; Rao, Calyampudi Radhakrishna
2018-06-05
The change-point detection has been carried out in terms of the Euclidean minimum spanning tree (MST) and shortest Hamiltonian path (SHP), with successful applications in the determination of authorship of a classic novel, the detection of change in a network over time, the detection of cell divisions, etc. However, these Euclidean graph-based tests may fail if a dataset contains random interferences. To solve this problem, we present a powerful non-Euclidean SHP-based test, which is consistent and distribution-free. The simulation shows that the test is more powerful than both Euclidean MST- and SHP-based tests and the non-Euclidean MST-based test. Its applicability in detecting both landing and departure times in video data of bees' flower visits is illustrated.
Can indirect tests detect a known recombination event in human mtDNA?
White, Daniel James; Gemmell, Neil John
2009-07-01
Whether human mitochondrial DNA (mtDNA) recombines sufficiently to influence its evolution, evolutionary analysis, and disease etiology, remains equivocal. Overall, evidence from indirect studies of population genetic data suggests that recombination is not occurring at detectable levels. This may be explained by no, or low, recombination or, alternatively, current indirect tests may be incapable of detecting recombination in human mtDNA. To investigate the latter, we have tested whether six well-established indirect tests of recombination could detect recombination in a human mtDNA data set, in which its occurrence had been empirically confirmed. Three showed statistical evidence for recombination (r(2) vs. distance, the Homoplasy test, Neighborhood Similarity Score), and three did not (D' vs. distance, Max Chi Squared, Pairwise Homoplasy Index). Possible reasons for detection failure are discussed. Further, evidence from earlier studies suggesting a lack of recombination in mtDNA in humans is reconsidered, taking into account the appropriateness of the tests used, based on our new findings.
Higgins, Sara N; Howden, Krista J; James, Carolyn R; Epp, Tasha; Lohmann, Katharina L
2017-12-01
This retrospective study was undertaken to estimate i) the surveillance coverage for equine infectious anemia (EIA) based on owner-requested testing, and ii) the incidence of case detection from this surveillance activity to inform a review of Canada's national disease control strategy. Based on sample submissions by accredited veterinarians to laboratories CFIA-approved for EIA testing between 2009 and 2012, the estimated national surveillance coverage was 14% for all years, and 72 cases of EIA were detected. The annual national incidence of EIA detection ranged from 0.03 to 0.08 cases/1000 horses. On average, a greater proportion of the horse population was tested in eastern Canada (32%) than in western Canada (6%, P < 0.0001). The cumulative incidence of EIA detection was higher in western Canada (0.25 cases/1000 horses) than in eastern Canada (0.02 cases/1000 horses, P < 0.0001). This study identified regional differences in owner-requested EIA testing and case detection resulting from this testing activity.
McLennan, Andrew; Palma-Dias, Ricardo; da Silva Costa, Fabricio; Meagher, Simon; Nisbet, Debbie L; Scott, Fergus
2016-02-01
There are limited data regarding noninvasive prenatal testing (NIPT) in low-risk populations, and the ideal aneuploidy screening model for a pregnant population has yet to be established. To assess the implementation of NIPT into clinical practice utilising both first- and second-line screening models. Three private practices specialising in obstetric ultrasound and prenatal diagnosis in Australia offered NIPT as a first-line test, ideally followed by combined first-trimester screening (cFTS), or as a second-line test following cFTS, particularly in those with a calculated risk between 1:50 and 1:1000. NIPT screening was performed in 5267 women and as a first-line screening method in 3359 (63.8%). Trisomies 21 and 13 detection was 100% and 88% for trisomy 18. Of cases with known karyotypes, the positive predictive value (PPV) of the test was highest for trisomy 21 (97.7%) and lowest for monosomy X (25%). Ultrasound detection of fetal structural abnormality resulted in the detection of five additional chromosome abnormalities, two of which had high-risk cFTS results. For all chromosomal abnormalities, NIPT alone detected 93.4%, a contingent model detected 81.8% (P = 0.097), and cFTS alone detected 65.9% (P < 0.005). NIPT achieved 100% T21 detection and had a higher DR of all aneuploidy when used as a first-line test. Given the false-positive rate for all aneuploidies, NIPT is an advanced screening test, rather than a diagnostic test. The benefit of additional cFTS was the detection of fetal structural abnormalities and some unusual chromosomal abnormalities. © 2016 The Royal Australian and New Zealand College of Obstetricians and Gynaecologists.
Yamanaka, Takashi; Nemoto, Manabu; Bannai, Hiroshi; Tsujimura, Koji; Kondo, Takashi; Matsumura, Tomio; Gildea, Sarah; Cullinane, Ann
2016-03-01
Equine influenza (EI) is a highly contagious disease caused by viruses of the H3N8 subtype. The rapid diagnosis of EI is essential to reduce the disease spread. Many rapid antigen detection (RAD) tests for diagnosing human influenza are available, but their ability to diagnose EI has not been systematically evaluated. The aim of this study was to compare the performance of 22 RAD tests in the diagnosis of EI. The 22 RAD tests were performed on fivefold serial dilutions of EI virus to determine their detection limits. The four most sensitive RAD tests (ImmunoAce Flu, BD Flu examan, Quick chaser Flu A, B and ESPLINE Influenza A&B-N) were further evaluated using nasopharyngeal samples collected from experimentally infected and naturally infected horses. The results were compared to those obtained using molecular tests. The detection limits of the 22 RAD tests varied hugely. Even the four RAD tests showing the best sensitivity were 125-fold less sensitive than the molecular techniques. The duration of virus detection in the experimentally infected horses was shorter using the RAD tests than using the molecular techniques. The RAD tests detected between 27% and 73% of real-time RT-PCR-positive samples from naturally infected horses. The study demonstrated the importance of choosing the right RAD tests as only three of 22 were fit for diagnosing EI. It was also indicated that even RAD tests with the highest sensitivity serve only as an adjunct to molecular tests because of the potential for false-negative results. © 2015 The Authors. Influenza and Other Respiratory Viruses Published by John Wiley & Sons Ltd.
Oligodeoxynucleotide Probes for Detecting Intact Cells
NASA Technical Reports Server (NTRS)
Rosson, Reinhardt A.; Maurina-Brunker, Julie; Langley, Kim; Pynnonen, Christine M.
2004-01-01
A rapid, sensitive test using chemiluminescent oligodeoxynucleotide probes has been developed for detecting, identifying, and enumerating intact cells. The test is intended especially for use in detecting and enumerating bacteria and yeasts in potable water. As in related tests that have been developed recently for similar purposes, the oligodeoxynucleotide probes used in this test are typically targeted at either singlecopy deoxyribonucleic acid (DNA) genes (such as virulence genes) or the multiple copies (10,000 to 50,000 copies per cell) of 16S ribosomal ribonucleic acids (rRNAs). Some of those tests involve radioisotope or fluorescent labeling of the probes for reporting hybridization of probes to target nucleic acids. Others of those tests involve labeling with enzymes plus the use of chemiluminescent or chromogenic substrates to report hybridization via color or the emission of light, respectively. The present test is of the last-mentioned type. The chemiluminescence in the present test can be detected easily with relatively simple instrumentation. In developing the present test, the hybridization approach was chosen because hybridization techniques are very specific. Hybridization detects stable, inheritable genetic targets within microorganisms. These targets are not dependent on products of gene expression that can vary with growth conditions or physiological states of organisms in test samples. Therefore, unique probes can be designed to detect and identify specific genera or species of bacteria or yeast (in terms of rRNA target sequences) or can be designed to detect and identify virulence genes (genomic target sequences). Because of the inherent specificity of this system, there are few problems of cross-reactivity. Hybridization tests are rapid, but hybridization tests now available commercially lack sensitivity; typically, between 10(exp 6) and 10(exp 7) cells of the target organism are needed to ensure a reliable test. Consequently, the numbers of target bacteria in samples are usually amplified by overnight pre-enrichment growth. These tests are usually performed in laboratories by skilled technicians. The present test was designed to overcome the shortcomings of the commercial hybridization tests. The figure summarizes the major steps of the test. It is important to emphasize that the hybridization process used in this test differs from that of other hybridization tests in that it does not extract target nucleic acids. This process is based on intact-cell hybridization (so-called in situ hybridization ), wherein the intact cells act as immobilizing agents. The cells are identified and enumerated by measuring the chemiluminescence emitted from alkaline phosphatase-probe (AP-probe) hybridization; the chemiluminescence is detected or measured by use of photographic film or a luminometer, respectively.
Statistics of software vulnerability detection in certification testing
NASA Astrophysics Data System (ADS)
Barabanov, A. V.; Markov, A. S.; Tsirlov, V. L.
2018-05-01
The paper discusses practical aspects of introduction of the methods to detect software vulnerability in the day-to-day activities of the accredited testing laboratory. It presents the approval results of the vulnerability detection methods as part of the study of the open source software and the software that is a test object of the certification tests under information security requirements, including software for communication networks. Results of the study showing the allocation of identified vulnerabilities by types of attacks, country of origin, programming languages used in the development, methods for detecting vulnerability, etc. are given. The experience of foreign information security certification systems related to the detection of certified software vulnerabilities is analyzed. The main conclusion based on the study is the need to implement practices for developing secure software in the development life cycle processes. The conclusions and recommendations for the testing laboratories on the implementation of the vulnerability analysis methods are laid down.
Towards Loophole-Free Optical Bell Test of CHSH Inequality
NASA Astrophysics Data System (ADS)
Tan, Yong-gang; Li, Hong-wei
2016-09-01
Bell test had been suggested to end the long-standing debate on the EPR paradox, while the imperfections of experimental devices induce some loopholes in Bell test experiments and hence the assumption of local reality by EPR cannot be excluded with current experimental results. In optical Bell test experiments, the locality loophole can be closed easily, while the attempt of closing detection loophole requires very high efficiency of single photon detectors. Previous studies showed that the violation of Clauser-Horne-Shimony-Holt (CHSH) inequality with maximally entangled states requires the detection efficiency to be higher than 82.8 %. In this paper, we raise a modified CHSH inequality that covers all measurement events including the efficient and inefficient detections in the Bell test and prove that all local hidden models can be excluded when the inequality is violated. We find that, when non-maximally entangled states are applied to the Bell test, the lowest detection efficiency for violation of the present inequality is 66.7 %. This makes it feasible to close the detection loophole and the locality loophole simultaneously in optical Bell test of CHSH inequality.
Rapid Detection of the Chlamydiaceae and Other Families in the Order Chlamydiales: Three PCR Tests
Everett, Karin D. E.; Hornung, Linda J.; Andersen, Arthur A.
1999-01-01
Few identification methods will rapidly or specifically detect all bacteria in the order Chlamydiales, family Chlamydiaceae. In this study, three PCR tests based on sequence data from over 48 chlamydial strains were developed for identification of these bacteria. Two tests exclusively recognized the Chlamydiaceae: a multiplex test targeting the ompA gene and the rRNA intergenic spacer and a TaqMan test targeting the 23S ribosomal DNA. The multiplex test was able to detect as few as 200 inclusion-forming units (IFU), while the TaqMan test could detect 2 IFU. The amplicons produced in these tests ranged from 132 to 320 bp in length. The third test, targeting the 23S rRNA gene, produced a 600-bp amplicon from strains belonging to several families in the order Chlamydiales. Direct sequence analysis of this amplicon has facilitated the identification of new chlamydial strains. These three tests permit ready identification of chlamydiae for diagnostic and epidemiologic study. The specificity of these tests indicates that they might also be used to identify chlamydiae without culture or isolation. PMID:9986815
Assessment of visual distortions in age-related macular degeneration: emergence of new approaches
Vazquez, Noelia Pitrelli; Knox, Paul C.
2016-01-01
Aims With the arrival of effective treatments for neovascular age-related macular degeneration (nvAMD) there is a need to find improved tests that would allow early detection. Ideally, these tests would allow monitoring of vision by patients themselves from home. The aim of this review is to discuss the available evidence for two recently developed vision tests designed for this purpose: the Preferential Hyperacuity Perimeter (PHP) test and the Radial Shape Discrimination (RSD) test. Methods Articles that investigated detection of nvAMD were reviewed. The methodology of the clinical evidence, where available, was judged for bias and applicability of the results to the general population using the QUADAS-2 quality assessment tool. Results The PHP test has proved to be good at detecting nvAMD but many studies assessed in this review were biased in the selection of patients, restricting the results to only those patients who can use the test and produce reliable results. On the other hand the RSD test is a simple test, well accepted by elderly patients with AMD. However, clinical studies to determine its value in the detection of early signs of nvAMD are still required. Conclusions To date, more studies have investigated the utility of the PHP test compared with the RSD test for detection of nvAMD. Both tests show promise but further evidence is needed to determine the real generalisability of the PHP test and the sensitivity of the RSD test. PMID:27738450
Histoplasma Urinary Antigen Testing Obviates the Need for Coincident Serum Antigen Testing.
Libert, Diane; Procop, Gary W; Ansari, Mohammad Q
2018-03-07
Serum and urine antigen (SAg, UAg) detection are common tests for Histoplasma capsulatum. UAg detection is more widely used and reportedly has a higher sensitivity. We investigated whether SAg detection contributes meaningfully to the initial evaluation of patients with suspected histoplasmosis. We reviewed 20,285 UAg and 1,426 SAg tests ordered from 1997 to 2016 and analyzed paired UAg and SAg tests completed on the same patient within 1 week. We determined the positivity rate for each test. Of 601 paired specimens, 542 were concurrent negatives and 48 were concurrent positives (98% agreement). Medical records were available for eight of 11 pairs with discrepant results. UAg was falsely positive in six instances, truly positive once, and falsely negative once. These findings support using a single antigen detection test, rather than both UAg and SAg, as an initial screen for suspected histoplasmosis. This aligns with the current practice of most physicians.
Method and apparatus for detecting and quantifying bacterial spores on a surface
NASA Technical Reports Server (NTRS)
Ponce, Adrian (Inventor)
2009-01-01
A method and an apparatus for detecting and quantifying bacterial spores on a surface. In accordance with the method: bacterial spores are transferred from a place of origin to a test surface, the test surface comprises lanthanide ions. Aromatic molecules are released from the bacterial spores; a complex of the lanthanide ions and aromatic molecules is formed on the test surface, the complex is excited to generate a characteristic luminescence on the test surface; the luminescence on the test surface is detected and quantified.
Method and Apparatus for Detecting and Quantifying Bacterial Spores on a Surface
NASA Technical Reports Server (NTRS)
Ponce, Adrian (Inventor)
2016-01-01
A method and an apparatus for detecting and quantifying bacterial spores on a surface. In accordance with the method: bacterial spores are transferred from a place of origin to a test surface, the test surface comprises lanthanide ions. Aromatic molecules are released from the bacterial spores; a complex of the lanthanide ions and aromatic molecules is formed on the test surface, the complex is excited to generate a characteristic luminescence on the test surface; the luminescence on the test surface is detected and quantified.
Van Dorst, Bieke; Brivio, Monica; Van Der Sar, Elfried; Blom, Marko; Reuvekamp, Simon; Tanzi, Simone; Groenhuis, Roelf; Adojutelegan, Adewole; Lous, Erik-Jan; Frederix, Filip; Stuyver, Lieven J
2016-04-15
In this manuscript, a microfluidic detection module, which allows a sensitive readout of biological assays in point-of-care (POC) tests, is presented. The proposed detection module consists of a microfluidic flow cell with an integrated Complementary Metal-Oxide-Semiconductor (CMOS)-based single photon counting optical sensor. Due to the integrated sensor-based readout, the detection module could be implemented as the core technology in stand-alone POC tests, for use in mobile or rural settings. The performance of the detection module was demonstrated in three assays: a peptide, a protein and an antibody detection assay. The antibody detection assay with readout in the detection module proved to be 7-fold more sensitive that the traditional colorimetric plate-based ELISA. The protein and peptide assay showed a lower limit of detection (LLOD) of 200 fM and 460 fM respectively. Results demonstrate that the sensitivity of the immunoassays is comparable with lab-based immunoassays and at least equal or better than current mainstream POC devices. This sensitive readout holds the potential to develop POC tests, which are able to detect low concentrations of biomarkers. This will broaden the diagnostic capabilities at the clinician's office and at patient's home, where currently only the less sensitive lateral flow and dipstick POC tests are implemented. Copyright © 2015 Elsevier B.V. All rights reserved.
Li, Qiang; Ou, Xi C; Pang, Yu; Xia, Hui; Huang, Hai R; Zhao, Bing; Wang, Sheng F; Zhao, Yan L
2017-07-01
MiniLab tuberculosis (ML TB) assay is a new automatic diagnostic tool for diagnosis of multidrug resistance tuberculosis (MDR-TB). This study was conducted with aims to know the performance of this assay. Sputum sample from 224 TB suspects was collected from tuberculosis suspects seeking medical care at Beijing Chest hospital. The sputum samples were directly used for smear and ML TB test. The left sputum sample was used to conduct Xpert MTB/RIF, Bactec MGIT culture and drug susceptibility test (DST). All discrepancies between the results from DST, molecular and phenotypic methods were confirmed by DNA Sequencing. The sensitivity and specificity of ML TB test for detecting MTBC from TB suspects were 95.1% and 88.9%, respectively. The sensitivity for smear negative TB suspects was 64.3%. For detection of RIF resistance, the sensitivity and specificity of ML TB test were 89.2% and 95.7%, respectively. For detection of INH resistance, the sensitivity and specificity of ML TB test were 78.3% and 98.1%, respectively. ML TB test showed similar performance to Xpert MTB/RIF for detection of MTBC and RIF resistance. In addition, ML TB also had good performance for INH resistance detection. Copyright © 2017. Published by Elsevier Ltd.
Study of acoustic emission during mechanical tests of large flight weight tank structure
NASA Technical Reports Server (NTRS)
Nakamura, Y.; Mccauley, B. O.; Veach, C. L.
1972-01-01
A polyphenylane oxide insulated, flight weight, subscale, aluminum tank was monitored for acoustic emissions during a proof test and during 100 cycles of environmental test simulating space flights. The use of a combination of frequency filtering and appropriate spatial filtering to reduce background noise was found to be sufficient to detect acoustic emission signals of relatively small intensity expected from subcritical crack growth in the structure. Several emission source locations were identified, including the one where a flaw was detected by post-test X-ray inspections. For most source locations, however, post-test inspections did not detect flaws; this was partially attributed to the higher sensitivity of the acoustic emission technique than any other currently available NDT method for detecting flaws.
Anion-intercalated layered double hydroxides modified test strips for detection of heavy metal ions.
Wang, Nan; Sun, Jianchao; Fan, Hai; Ai, Shiyun
2016-01-01
In this work, a novel approach for facile and rapid detection of heavy metal ions using anion-intercalated layered double hydroxides (LDHs) modified test strips is demonstrated. By intercalating Fe(CN)6(4-) or S(2-) anions into the interlayers of LDHs on the filter paper, various heavy metal ions can be easily detected based on the color change before and after reaction between the anions and the heavy metal ions. Upon the dropping of heavy metal ions solutions to the test strips, the colors of the test strips changed instantly, which can be easily observed by naked eyes. With the decrease of the concentration, the color depth changed obviously. The lowest detection concentration can be up to 1×10(-6) mol L(-1). Due to the easily intercalation of anions into the interlayer of the LDHs on test trips, this procedure provides a general method for the construction of LDHs modified test strips for detection of heavy metal ions. The stability of the prepared test strips is investigated. Furthermore, all the results were highly reproducible. The test strips may have potential applications in environmental monitoring fields. Copyright © 2015 Elsevier B.V. All rights reserved.
Ding, Qianlan; Wu, Xi; Lu, Yeling; Chen, Changming; Shen, Rui; Zhang, Xi; Jiang, Zhengwen; Wang, Xuefeng
2016-07-01
To develop a digitalized intron 22 inversion (Inv22) detection in patients with severe haemophilia A. The design included two tests: A genotyping test included two multiplex pre-amplification of LD-PCR (PLP) with two combinations of five primers to amplify wild-type and chimeric int22h alleles; a carrier mosaicism test was similar to the genotyping test except only amplification of chimeric int22h alleles by removing one primer from each of two combinations. AccuCopy detection was used to quantify PLP products. PLP product patterns in the genotyping test allowed identifying all known Inv22. Quantitative patterns accurately represented the product patterns. The results of 164 samples detected by the genotyping test were consistent with those obtained by LD-PCR detection. Limit of detection (LOD) of the carrier mosaicism test was at least 2% of heterozygous cells with Inv22. Performing the test in two obligate mothers with negative Inv22 from two sporadic pedigrees mosaic rates of blood and hair root of the mother from pedigree 1 were 8.3% and >20%, respectively and negative results were obtained in pedigree 2. AccuCopy quantification combined with PLP (AQ-PLP) method was confirmed to be rapid and reliable for genotyping Inv22 and highly sensitive to carrier mosaicism detection. Copyright © 2016 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Colotelo, Alison HA; Smokorowski, Karen; Haxton, Tim
Current methods of fish epithelial injury detection are limited to gross macroscopic examination that has a subjective bias as well as an inability to reliably quantify the degree of injury. Fluorescein, a presumptive test for blood, has been shown to have the capability to detect and quantify fish epithelial injury. However, there are several other presumptive tests for blood (Bluestar*, phenolphthalein, and HemastixH) that may have benefits over the use of fluorescein, particularly for field research on wild fish. This study investigated the capabilities of these four tests to detect and quantify a variety of injuries commonly encountered by fishmore » (abrasion, cuts, fin frays, and punctures) using the freshwater bluegill Lepomis macrochirus as a model. Fluorescein was consistently found to be the most reliable (i.e., detected the highest proportion of true positive results and rarely detected false positive reactions) of the four presumptive tests for blood compared. Further testing was conducted to examine the reliability of fluorescein. By 24 h after an injury was inflicted, the injury was no longer detectable by fluorescein, and when fluorescein was applied to an injured fish, the fluorescein was no longer detectable 3 h after application. In a comparison of two common anaesthetics used in fisheries research, there was no significant difference in the proportion of injury detected when 3- aminobenzoic acid ethyl ester methanesulfate (tricaine) was used compared with a clove oil and ethanol (1:9) solution. In summary, fluorescein was the most reliable presumptive test for blood examined in this study for the detection and quantification of recent (hours) fish epithelial injury.« less
de la Torre, R; Badia, R; Gonzàlez, G; García, M; Pretel, M J; Farré, M; Segura, J
1996-01-01
We investigated the usefulness of immunological methods for presumptive detection of stimulants found in sports drug testing. The ingestion of substances that show no cross-reactivity in tests commercially available for the detection of amphetamines can produce positive results in the urine. Human metabolism contributes to the positive results of some urine samples when the parent compound does not cross-react with the antibodies of the assay. Urine samples from healthy volunteers given stimulants were tested by chromatographic methods and by two different fluorescence polarization immunoassays (FPIA) from Abbott Laboratories for the analysis of amphetamines. According to the results obtained, we classified stimulants into four groups: detectable stimulants that gave rise to amphetamine by human metabolism (group 1); detectable ephedrines and related compounds, appearing in the urine either as parent compounds or originated by metabolism (group 2); detectable stimulants that displayed actual cross-reactivity with amphetamine tests (group 3); and stimulants not detected by FPIA (group 4). Most of the true doping cases due to the ingestion of stimulants may be detected by FPIA. The specificity of the results may be increased by combining immunological assays with different antibodies.
Telford, Jennifer; Gentile, Laura; Gondara, Lovedeep; McGahan, Colleen; Coldman, Andrew
2016-01-01
British Columbia undertook a colorectal cancer screening pilot program in 3 communities. Our objective was to assess the performance of 2-specimen fecal immunochemical testing in the detection of colorectal neoplasms in this population-based screening program. A prospective cohort of asymptomatic, average-risk people aged 50 to 74 years completed 2 quantitative fecal immunochemical tests every 2 years, with follow-up colonoscopy if the result of either test was positive. Participant demographics, fecal immunochemical test results, colonoscopy quality indicators and pathology results were recorded. Non-screen-detected colorectal cancer that developed in program participants was identified through review of data from the BC Cancer Registry. A total of 16 234 people completed a first round of fecal immunochemical testing, with a positivity rate of 8.6%; 5378 (86.0% of eligible participants) completed a second round before the end of the pilot program, with a positivity rate of 6.7%. Of the 1756 who had a positive test result, 1555 (88.6%) underwent colonoscopy. The detection rate of colorectal cancer was 3.5 per 1000 participants. The positive predictive value of the fecal immunochemical test was 4.9% (95% confidence interval [CI] 3.8%-6.0%) for colorectal cancer, 35.0% (95% CI 32.5%-37.2%) for high-risk polyps and 62.0% (95% CI 59.6%-64.4%) for all neoplasms. The number needed to screen was 283 to detect 1 cancer, 40 to detect 1 high-risk polyp and 22 to detect any neoplasm. Screening every 2 years with a 2-specimen fecal immunochemical test surpassed the current benchmark for colorectal cancer detection in population-based screening. This study has implications for other jurisdictions planning colorectal cancer screening programs.
Lim, Myong Cheol; Lee, Do-Hoon; Hwang, Sang-Hyun; Hwang, Na Rae; Lee, Bomyee; Shin, Hye Young; Jun, Jae Kwan; Yoo, Chong Woo; Lee, Dong Ock; Seo, Sang-Soo; Park, Sang-Yoon; Joo, Jungnam
2017-05-01
Human papillomavirus (HPV) testing based on cervical samples is important for use in cervical cancer screening. However, cervical sampling is invasive. Therefore, non-invasive methods for detecting HPV, such as urine samples, are needed. For HPV detection in urine samples, two real-time PCR (RQ-PCR) tests, Roche cobas 4800 test (Roche_HPV; Roche Molecular Diagnostics) and Abbott RealTime High Risk HPV test (Abbott_HPV; Abbott Laboratories) were compared to standard cervical samples. The performance of Roche_HPV and Abbott_HPV for HPV detection was evaluated at the National Cancer Center using 100 paired cervical and urine samples. The tests were also compared using urine samples stored at various temperatures and for a range of durations. The overall agreement between the Roche_HPV and Abbott_HPV tests using urine samples for any hrHPV type was substantial (86.0% with a kappa value of 0.7173), and that for HPV 16/18 was nearly perfect (99.0% with a kappa value of 0.9668). The relative sensitivities (based on cervical samples) for HPV 16/18 detection using Roche_HPV and Abbott_HPV with urine samples were 79.2% (95% CI; 57.9-92.9%) and 81.8% (95% CI; 59.7-94.8%), respectively. When the cut-off C T value for Abbott_HPV was extended to 40 for urine samples, the relative sensitivity of Abbott_HPV increased to 91.7% from 81.8% for HPV16/18 detection and to 87.0% from 68.5% for other hrHPV detection. The specificity was not affected by the change in the C T threshold. Roche_HPV and Abbott_HPV showed high concordance. However, HPV DNA detection using urine samples was inferior to HPV DNA detection using cervical samples. Interestingly, when the cut-off C T value was set to 40, Abbott_HPV using urine samples showed high sensitivity and specificity, comparable to those obtained using cervical samples. Fully automated DNA extraction and detection systems, such as Roche_HPV and Abbott_HPV, could reduce the variability in HPV detection and accelerate the standardization of HPV detection in urine. Thus, urine samples may be an effective alternative for HPV detection in women who hesitate to participate in cervical cancer screening programs. Copyright © 2017 Elsevier B.V. All rights reserved.
9 CFR 113.37 - Detection of pathogens by the chicken embryo inoculation test.
Code of Federal Regulations, 2010 CFR
2010-01-01
... embryo inoculation test. 113.37 Section 113.37 Animals and Animal Products ANIMAL AND PLANT HEALTH... inoculation test. The test for detection of extraneous pathogens provided in this section shall be conducted when such a test is prescribed in an applicable Standard Requirement or in the filed Outline of...
9 CFR 113.37 - Detection of pathogens by the chicken embryo inoculation test.
Code of Federal Regulations, 2012 CFR
2012-01-01
... embryo inoculation test. 113.37 Section 113.37 Animals and Animal Products ANIMAL AND PLANT HEALTH... inoculation test. The test for detection of extraneous pathogens provided in this section shall be conducted when such a test is prescribed in an applicable Standard Requirement or in the filed Outline of...
Koppelman, Marco H G M; Cuijpers, H Theo M; Wessberg, Susanna; Valkeajärvi, Anne; Pichl, Lutz; Schottstedt, Volkmar; Saldanha, John
2012-07-01
Three European laboratories evaluated the TaqScreen DPX test (DPX test), a multiplex nucleic acid test assay for the simultaneous detection and quantitation of parvovirus B19 (B19V) DNA and the detection of hepatitis A virus (HAV) RNA. The 95% limit of detection of the test for B19V and HAV was determined using the respective WHO International Standards. The reproducibility of the test was evaluated by testing replicate samples of B19V at log 4.0 and 40 IU/mL and HAV at 5 IU/mL. The accuracy of the DPX test for B19V was evaluated by replicate testing of B19V samples containing log 3.0, log 4.0, and log 5.0 IU/mL. Panels of B19V Genotypes 1, 2, and 3 and HAV genotypes were evaluated. Cross-contamination was evaluated. For comparison of the DPX test and the established tests, the sites tested plasma samples in pools of either 96 or 480 donations. The mean 95% lower limits of detection of the three laboratories for B19V and HAV were 20.30 and 1.85 IU/mL. The test showed good reproducibility with the major part of the variance of the test being attributed to intermediate assay variation. The test showed great accuracy for B19V, especially at log 4.0 IU/mL. Spiking of test pools of 480 donations and manufacturing pools with log 4.0 IU/mL B19 DNA and 4 IU/mL HAV RNA showed that the DPX assay was robust. The test was able to detect the three genotypes of B19V and HAV genotypes. No cross-contamination was seen. Test results of routine samples correlated well with those of the established tests. The DPX test is a robust and sensitive test for the detection of B19V and HAV in plasma samples. The quantitative B19V results obtained with the test are accurate, and the test is able to detect all the known genotypes of B19V and HAV and fulfills all the European Pharmacopoeia and Food and Drug Administration requirements for a B19V and HAV test for screening of plasma donations and samples from plasma pools for manufacture. © 2012 American Association of Blood Banks.
Athanasiou, Labrini V; Petanides, Theodoros A; Chatzis, Manolis K; Kasabalis, Dimitrios; Apostolidis, Kosmas N; Saridomichelakis, Manolis N
2014-03-01
Antibodies against Leishmania spp. are detected in most dogs with clinical signs of leishmaniasis due to Leishmania infantum. Accurate, rapid in-clinic serological tests may permit immediate confirmation of the diagnosis and implementation of therapeutic measures. The aim of the current study was to evaluate the diagnostic accuracy of 2 commercial, rapid in-clinic serological tests for the detection of anti-Leishmania antibodies in sera of dogs, the Snap Canine Leishmania Antibody Test kit (IDEXX Laboratories Inc., Westbrook, Maine) and the ImmunoRun Antibody Detection kit (Biogal Galed Labs, Kibbutz Galed, Israel), using indirect fluorescent antibody test (IFAT) as the reference method. A total of 109 sera collected from 65 seropositive and 44 seronegative dogs were used. The sensitivities of the Snap and ImmunoRun kits were 89.23% (95% confidence interval: 79.05-95.54%) and 86.15% (95% confidence interval: 75.33-93.45%), respectively, and the specificity of both tests was 100%. A good agreement between each of the rapid in-clinic serological tests and IFAT and between the 2 rapid in-clinic serological tests was witnessed. Both rapid in-clinic serological tests showed an adequate diagnostic accuracy and can be used for the fast detection of antibodies against L. infantum in dogs.
A Space Object Detection Algorithm using Fourier Domain Likelihood Ratio Test
NASA Astrophysics Data System (ADS)
Becker, D.; Cain, S.
Space object detection is of great importance in the highly dependent yet competitive and congested space domain. Detection algorithms employed play a crucial role in fulfilling the detection component in the situational awareness mission to detect, track, characterize and catalog unknown space objects. Many current space detection algorithms use a matched filter or a spatial correlator to make a detection decision at a single pixel point of a spatial image based on the assumption that the data follows a Gaussian distribution. This paper explores the potential for detection performance advantages when operating in the Fourier domain of long exposure images of small and/or dim space objects from ground based telescopes. A binary hypothesis test is developed based on the joint probability distribution function of the image under the hypothesis that an object is present and under the hypothesis that the image only contains background noise. The detection algorithm tests each pixel point of the Fourier transformed images to make the determination if an object is present based on the criteria threshold found in the likelihood ratio test. Using simulated data, the performance of the Fourier domain detection algorithm is compared to the current algorithm used in space situational awareness applications to evaluate its value.
NASA Astrophysics Data System (ADS)
Schoolderman, Arnold J.; Roosenboom, Jacques H. J.
2005-06-01
The Engineers Centre of Expertise of the Royal Netherlands Army (RNLA) has conducted a study on countermine in peace operations. This study, finished in 2002, concluded that the final solution to countermine will depend in the first place on better detection of buried low-metal mines, e.g. by direct detection of the explosive components in mines. Until such detection systems are available, intermediate solutions are necessary in order to assure freedom of movement in peace operations. Because countermine operations consist of a number of different activities (area preparation, detection, clearance, etc) and the suitability of the different types of available equipment depends on the scenario, the toolbox concept for countermine equipment was adopted. In 2003 a procurement process was started in order to fill this toolbox with commercial-off-the-shelf and military-off-the-shelf equipment. The paper gives a concise description of the study on countermine operations and the procurement process, and subsequently focuses on the set-up of the tests that were conducted in the framework of the procurement of hand-held mine detection systems, like metal detectors and dual-sensor mine detectors. Programs of requirements for these systems were drawn up, aiming at systems for general use and special purpose systems. Blind tests to check the compliancy to the detection performance requirements were designed and conducted in the short timeframe that was available in the procurement process. These tests are discussed in this paper, including the set-up of the test lanes, the targets used and their depths, and the role of the operator. The tests of the capability of the detectors to discriminate small targets adjacent to large targets were conducted according the guidelines of the CEN Workshop Agreement on metal detector tests. Although the results of the tests are commercially confidential, conclusions and lessons learned from the execution of these tests are presented.
Budal, Elisabeth B; Haugland, Hans K; Skar, Robert; Maehle, Bjørn O; Bjørge, Tone; Vintermyr, Olav K
2014-02-01
In Norway, Pap smears with atypical squamous cells of uncertain significance (ASCUS) and low-grade squamous intraepithelial lesions (LSIL) are triaged after 6 months. The aim of the study was to evaluate effects of implementing human papillomavirus (HPV) test (2005) in delayed triage of ASCUS and LSIL in a cohort of women from Western Norway. After a survey of 119,469 cervical Pap smears during 2005-2007, a total of 1055 women with an index ASCUS or LSIL were included in the study and followed up for 3-6 years with respect to progression into cervical intraepithelial neoplasia grade 2 or worse (CIN2+). Overall sensitivity for detection of CIN2+ with HPV testing and cytology was 96% and 72%, respectively. The sensitivity for detection of CIN2+ was not affected by age, but the specificity of the HPV test increased with age. Thus, for the age groups <34 years, 34-50 years, and >50 years, the specificity of a positive HPV test to detect CIN2+ was 47%, 71%, and 82%, respectively. Positive predictive values for CIN2+ in women with positive cytology, positive HPV test, negative cytology, negative HPV test, or negative HPV and cytology tests were 52%, 41%, 8%, 1.5%, and 0.4%, respectively. HPV testing resulted in a net 22% increased detection of CIN2+. Fifty-six percent of CIN2+ was detected at an earlier time point with HPV testing in triage. Implementation of HPV testing in delayed triage of ASCUS and LSIL improved the stratification of CIN2+ risk and increased CIN2+ detection and at an earlier time point than with triage by cytology alone. © 2013 The Authors. Cancer Medicine published by John Wiley & Sons Ltd.
Budal, Elisabeth B; Haugland, Hans K; Skar, Robert; Mæhle, Bjørn O; Bjørge, Tone; Vintermyr, Olav K
2014-01-01
In Norway, Pap smears with atypical squamous cells of uncertain significance (ASCUS) and low-grade squamous intraepithelial lesions (LSIL) are triaged after 6 months. The aim of the study was to evaluate effects of implementing human papillomavirus (HPV) test (2005) in delayed triage of ASCUS and LSIL in a cohort of women from Western Norway. After a survey of 119,469 cervical Pap smears during 2005–2007, a total of 1055 women with an index ASCUS or LSIL were included in the study and followed up for 3–6 years with respect to progression into cervical intraepithelial neoplasia grade 2 or worse (CIN2+). Overall sensitivity for detection of CIN2+ with HPV testing and cytology was 96% and 72%, respectively. The sensitivity for detection of CIN2+ was not affected by age, but the specificity of the HPV test increased with age. Thus, for the age groups <34 years, 34–50 years, and >50 years, the specificity of a positive HPV test to detect CIN2+ was 47%, 71%, and 82%, respectively. Positive predictive values for CIN2+ in women with positive cytology, positive HPV test, negative cytology, negative HPV test, or negative HPV and cytology tests were 52%, 41%, 8%, 1.5%, and 0.4%, respectively. HPV testing resulted in a net 22% increased detection of CIN2+. Fifty-six percent of CIN2+ was detected at an earlier time point with HPV testing in triage. Implementation of HPV testing in delayed triage of ASCUS and LSIL improved the stratification of CIN2+ risk and increased CIN2+ detection and at an earlier time point than with triage by cytology alone. PMID:24403090
A pdf-Free Change Detection Test Based on Density Difference Estimation.
Bu, Li; Alippi, Cesare; Zhao, Dongbin
2018-02-01
The ability to detect online changes in stationarity or time variance in a data stream is a hot research topic with striking implications. In this paper, we propose a novel probability density function-free change detection test, which is based on the least squares density-difference estimation method and operates online on multidimensional inputs. The test does not require any assumption about the underlying data distribution, and is able to operate immediately after having been configured by adopting a reservoir sampling mechanism. Thresholds requested to detect a change are automatically derived once a false positive rate is set by the application designer. Comprehensive experiments validate the effectiveness in detection of the proposed method both in terms of detection promptness and accuracy.
Identification and detection of anomalies through SSME data analysis
NASA Technical Reports Server (NTRS)
Pereira, Lisa; Ali, Moonis
1990-01-01
The goal of the ongoing research described in this paper is to analyze real-time ground test data in order to identify patterns associated with the anomalous engine behavior, and on the basis of this analysis to develop an expert system which detects anomalous engine behavior in the early stages of fault development. A prototype of the expert system has been developed and tested on the high frequency data of two SSME tests, namely Test #901-0516 and Test #904-044. The comparison of our results with the post-test analyses indicates that the expert system detected the presence of the anomalies in a significantly early stage of fault development.
Combating Terrorism: 2005 TSWG Review
2005-01-01
will have a greater capacity and will be more compact than existing kits. Advanced Hybrid Chemical Detection System Existing sensor systems to...detect chemical agents are either very expensive or provide limited sensitivity and response. Avir, LLC designed and built a hybrid detection system for... hybrid system at an equally low cost. The system has undergone live-agent testing and environmental testing. Extended field-testing in select buildings
Test/QA Plan for Verification of Leak Detection and Repair Technologies
The purpose of the leak detection and repair (LDAR) test and quality assurance plan is to specify procedures for a verification test applicable to commercial LDAR technologies. The purpose of the verification test is to evaluate the performance of participating technologies in b...
Perez, Leandro Reus Rodrigues; Dias, Cícero; d'Azevedo, Pedro Alves
2008-08-01
In this study we evaluated the performance of the oxacillin agar screen test, and agar dilution tests using cefoxitin and oxacillin antimicrobials, to detect meticillin resistance in Staphylococcus aureus isolates. The presence of the mecA gene, detected by PCR, was used as the standard to which agar screen and agar dilution tests were compared. The best performance was obtained using the agar dilution test (99.4 % accuracy) with breakpoints of 4 mug ml(-1) for oxacillin and 8 mug ml(-1) for cefoxitin, and using the oxacillin agar screen test. Also, a strong correlation between MIC values of cefoxitin and oxacillin permits the use of either drug for detection of meticillin resistance.
NASA Technical Reports Server (NTRS)
Medelius, Pedro J. (Inventor); Simpson, Howard J. (Inventor)
1999-01-01
A cable tester is described for low frequency testing of a cable for faults. The tester allows for testing a cable beyond a point where a signal conditioner is installed, minimizing the number of connections which have to be disconnected. A magnetic pickup coil is described for detecting a test signal injected into the cable. A narrow bandpass filter is described for increasing detection of the test signal. The bandpass filter reduces noise so that a high gain amplifier provided for detecting a test signal is not completely saturate by noise. To further increase the accuracy of the cable tester, processing gain is achieved by comparing the signal from the amplifier with at least one reference signal emulating the low frequency input signal injected into the cable. Different processing techniques are described evaluating a detected signal.
Pasteran, Fernando; Tijet, Nathalie; Melano, Roberto G.
2015-01-01
We compared carbapenemase detection among 266 Gram-negative bacilli (161 carbapenemase producers) using the Carba NP tests issued by the CLSI (CNPt-CLSI) and a novel protocol (CNPt-direct) designed for carbapenemase detection direct from bacterial cultures (instead of bacterial extracts required by the CLSI tests). The specificities were comparable (100%), but the CNPt-direct was more sensitive (98% versus 84%). The CNPt-direct was easier to perform due to the direct use of colonies and offered a more robust detection of carbapenemase producers. PMID:26424841
NASA Astrophysics Data System (ADS)
Havens, Timothy C.; Spain, Christopher J.; Ho, K. C.; Keller, James M.; Ton, Tuan T.; Wong, David C.; Soumekh, Mehrdad
2010-04-01
Forward-looking ground-penetrating radar (FLGPR) has received a significant amount of attention for use in explosivehazards detection. A drawback to FLGPR is that it results in an excessive number of false detections. This paper presents our analysis of the explosive-hazards detection system tested by the U.S. Army Night Vision and Electronic Sensors Directorate (NVESD). The NVESD system combines an FLGPR with a visible-spectrum color camera. We present a target detection algorithm that uses a locally-adaptive detection scheme with spectrum-based features. The remaining FLGPR detections are then projected into the camera imagery and image-based features are collected. A one-class classifier is then used to reduce the number of false detections. We show that our proposed FLGPR target detection algorithm, coupled with our camera-based false alarm (FA) reduction method, is effective at reducing the number of FAs in test data collected at a US Army test facility.
Sonmez, Cemile; Coplu, Nilay; Gozalan, Aysegul; Akin, Lutfu; Esen, Berrin
2017-06-01
Detection of anti-tetanus antibody levels is necessary for both determination of the immune status of individuals and also for planning preventive measures. ELISA is the preferred test among in vitro tests however it can be affected by the cross reacting antibodies. A previously developed in-house ELISA test was found not reliable for the antibody levels ≤1.0IU/ml. A new method was developed to detect low antibody levels correctly. The aim of the present study was to compare the results of the newly developed in-house biotin-avidin tetanus IgG ELISA test with the in vivo mouse neutralization test, for the antibody levels ≤1.0IU/ml. A total of 54 serum samples with the antibody levels of three different levels, =0.01IU/ml, 0.01-0.1IU/ml, 0.1-1IU/ml, which were detected by in vivo mouse neutralization test were studied by the newly developed in-house biotin-avidin tetanus IgG ELISA test. Test was validated by using five different concentrations (0.01IU/ml, 0.06IU/ml, 0.2IU/ml, 0.5IU/ml, 1.0IU/ml). A statistically significant correlation (r 2 =0.9967 p=0,001) between in vivo mouse neutralization test and in-house biotin-avidin tetanus IgG ELISA test, was observed. For the tested concentrations intra-assay, inter-assay, accuracy, sensitivity, specificity and coefficients of variations were determined as ≤15%. In-house biotin-avidin tetanus IgG ELISA test can be an alternative method to in vivo mouse neutralization method for the detection of levels ≤1.0IU/ml. By using in-house biotin-avidin tetanus IgG ELISA test, individuals with non protective levels, will be reliably detected. Copyright © 2017. Published by Elsevier B.V.
Peters, Philip J; Westheimer, Emily; Cohen, Stephanie; Hightow-Weidman, Lisa B; Moss, Nicholas; Tsoi, Benjamin; Hall, Laura; Fann, Charles; Daskalakis, Demetre C; Beagle, Steve; Patel, Pragna; Radix, Asa; Foust, Evelyn; Kohn, Robert P; Marmorino, Jenni; Pandori, Mark; Fu, Jie; Samandari, Taraz; Gay, Cynthia L
2016-02-16
Although acute HIV infection contributes disproportionately to onward HIV transmission, HIV testing has not routinely included screening for acute HIV infection. To evaluate the performance of an HIV antigen/antibody (Ag/Ab) combination assay to detect acute HIV infection compared with pooled HIV RNA testing. Multisite, prospective, within-individual comparison study conducted between September 2011 and October 2013 in 7 sexually transmitted infection clinics and 5 community-based programs in New York, California, and North Carolina. Participants were 12 years or older and seeking HIV testing, without known HIV infection. All participants with a negative rapid HIV test result were screened for acute HIV infection with an HIV Ag/Ab combination assay (index test) and pooled human immunodeficiency virus 1 (HIV-1) RNA testing. HIV RNA testing was the reference standard, with positive reference standard result defined as detectable HIV-1 RNA on an individual RNA test. Number and proportion with acute HIV infections detected. Among 86,836 participants with complete test results (median age, 29 years; 75.0% men; 51.8% men who have sex with men), established HIV infection was diagnosed in 1158 participants (1.33%) and acute HIV infection was diagnosed in 168 participants (0.19%). Acute HIV infection was detected in 134 participants with HIV Ag/Ab combination testing (0.15% [95% CI, 0.13%-0.18%]; sensitivity, 79.8% [95% CI, 72.9%-85.6%]; specificity, 99.9% [95% CI, 99.9%-99.9%]; positive predictive value, 59.0% [95% CI, 52.3%-65.5%]) and in 164 participants with pooled HIV RNA testing (0.19% [95% CI, 0.16%-0.22%]; sensitivity, 97.6% [95% CI, 94.0%-99.4%]; specificity, 100% [95% CI, 100%-100%]; positive predictive value, 96.5% [95% CI, 92.5%-98.7%]; sensitivity comparison, P < .001). Overall HIV Ag/Ab combination testing detected 82% of acute HIV infections detectable by pooled HIV RNA testing. Compared with rapid HIV testing alone, HIV Ag/Ab combination testing increased the relative HIV diagnostic yield (both established and acute HIV infections) by 10.4% (95% CI, 8.8%-12.2%) and pooled HIV RNA testing increased the relative HIV diagnostic yield by 12.4% (95% CI, 10.7%-14.3%). In a high-prevalence population, HIV screening using an HIV Ag/Ab combination assay following a negative rapid test detected 82% of acute HIV infections detectable by pooled HIV RNA testing, with a positive predictive value of 59%. Further research is needed to evaluate this strategy in lower-prevalence populations and in persons using preexposure prophylaxis for HIV prevention.
Object Detection for Agricultural and Construction Environments Using an Ultrasonic Sensor.
Dvorak, J S; Stone, M L; Self, K P
2016-04-01
This study tested an ultrasonic sensor's ability to detect several objects commonly encountered in outdoor agricultural or construction environments: a water jug, a sheet of oriented strand board (OSB), a metalfence post, a human model, a wooden fence post, a Dracaena plant, a juniper plant, and a dog model. Tests were performed with each target object at distances from 0.01 to 3 m. Five tests were performed with each object at each location, and the sensor's ability to detect the object during each test was categorized as "undetected," "intermittent," "incorrect distance," or "good." Rigid objects that presented a larger surface area to the sensor, such as the water jug and OSB, were better detected than objects with a softer surface texture, which were occasionally not detected as the distance approached 3 m. Objects with extremely soft surface texture, such as the dog model, could be undetected at almost any distance from the sensor. The results of this testing should help designers offuture systems for outdoor environments, as the target objects tested can be found in nearly any agricultural or construction environment.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shull, D.
This report documents the initial feasibility tests performed using a commercial acoustic emission instrument for the purpose of detecting beetles in Department of Energy 9975 shipping packages. The device selected for this testing was a commercial handheld instrument and probe developed for the detection of termites, weevils, beetles and other insect infestations in wooden structures, trees, plants and soil. The results of two rounds of testing are presented. The first tests were performed by the vendor using only the hand-held instrument’s indications and real-time operator analysis of the audio signal content. The second tests included hands-free positioning of the instrumentmore » probe and post-collection analysis of the recorded audio signal content including audio background comparisons. The test results indicate that the system is promising for detecting the presence of drugstore beetles, however, additional work would be needed to improve the ease of detection and to automate the signal processing to eliminate the need for human interpretation. Mechanisms for hands-free positioning of the probe and audio background discrimination are also necessary for reliable detection and to reduce potential operator dose in radiation environments.« less
NASA Astrophysics Data System (ADS)
Min, Qing-xu; Zhu, Jun-zhen; Feng, Fu-zhou; Xu, Chao; Sun, Ji-wei
2017-06-01
In this paper, the lock-in vibrothermography (LVT) is utilized for defect detection. Specifically, for a metal plate with an artificial fatigue crack, the temperature rise of the defective area is used for analyzing the influence of different test conditions, i.e. engagement force, excitation intensity, and modulated frequency. The multivariate nonlinear and logistic regression models are employed to estimate the POD (probability of detection) and POA (probability of alarm) of fatigue crack, respectively. The resulting optimal selection of test conditions is presented. The study aims to provide an optimized selection method of the test conditions in the vibrothermography system with the enhanced detection ability.
Detecting Test Tampering Using Item Response Theory
ERIC Educational Resources Information Center
Wollack, James A.; Cohen, Allan S.; Eckerly, Carol A.
2015-01-01
Test tampering, especially on tests for educational accountability, is an unfortunate reality, necessitating that the state (or its testing vendor) perform data forensic analyses, such as erasure analyses, to look for signs of possible malfeasance. Few statistical approaches exist for detecting fraudulent erasures, and those that do largely do not…
Preechakasedkit, Pattarachaya; Pinwattana, Kulwadee; Dungchai, Wijitar; Siangproh, Weena; Chaicumpa, Wanpen; Tongtawe, Pongsri; Chailapakul, Orawon
2012-01-15
An immunochromatographic strip test using gold nanoparticles was developed for the rapid detection of Salmonella typhi (S. typhi) in human serum. The strip test based on the principle of sandwich immunoassay by the specific binding of antigens from S. typhi O901 and antibody of S. typhi O901 on a nitrocellulose membrane. Antibody-gold nanoparticle conjugate was used as the label and was coated onto a glass fiber membrane, which was used as a conjugate pad. To create a test and control zone, antibody of S. typhi O901 and an anti-IgG were dotted on the nitrocellulose membrane, respectively. Positive samples were displayed as red dots at the test and control zones of the nitrocellulose membrane, while negative samples resulted in a red dot only in the control zone. The limit of detection (LOD) was found to be 1.14×10(5) cfu mL(-1), which could be visually detected by the naked eye within 15 min. This strip test provided a lower detection limit and analysis time than a dot blot immunoassay (8.88×10(6) cfu mL(-1) for LOD and 110 min for reaction time). In addition, our immunochromatographic strip test was employed to detect S. typhi in human serum effectively, with high accuracy. This strip test offers great promise for a rapid, simple and low-cost analysis of S. typhi. Copyright © 2011 Elsevier B.V. All rights reserved.
Detection of Blood in Stable Flies (Diptera: Muscidae) with Hemoccult® Test Strips
USDA-ARS?s Scientific Manuscript database
Hemoccult® test kits were used to detect the remnants of blood meals in stable flies. The strips were able to detect remnants of blood meals in > 90% of the stable flies up to 8 days after blood feeding. This can be compared with detecting blood in the gut visually which was possible in less than 5%...
NASA Astrophysics Data System (ADS)
Tibbetts, Clark; Lichanska, Agnieszka M.; Borsuk, Lisa A.; Weslowski, Brian; Morris, Leah M.; Lorence, Matthew C.; Schafer, Klaus O.; Campos, Joseph; Sene, Mohamadou; Myers, Christopher A.; Faix, Dennis; Blair, Patrick J.; Brown, Jason; Metzgar, David
2010-04-01
High-density resequencing microarrays support simultaneous detection and identification of multiple viral and bacterial pathogens. Because detection and identification using RPM is based upon multiple specimen-specific target pathogen gene sequences generated in the individual test, the test results enable both a differential diagnostic analysis and epidemiological tracking of detected pathogen strains and variants from one specimen to the next. The RPM assay enables detection and identification of pathogen sequences that share as little as 80% sequence similarity to prototype target gene sequences represented as detector tiles on the array. This capability enables the RPM to detect and identify previously unknown strains and variants of a detected pathogen, as in sentinel cases associated with an infectious disease outbreak. We illustrate this capability using assay results from testing influenza A virus vaccines configured with strains that were first defined years after the design of the RPM microarray. Results are also presented from RPM-Flu testing of three specimens independently confirmed to the positive for the 2009 Novel H1N1 outbreak strain of influenza virus.
Verifying Digital Components of Physical Systems: Experimental Evaluation of Test Quality
NASA Astrophysics Data System (ADS)
Laputenko, A. V.; López, J. E.; Yevtushenko, N. V.
2018-03-01
This paper continues the study of high quality test derivation for verifying digital components which are used in various physical systems; those are sensors, data transfer components, etc. We have used logic circuits b01-b010 of the package of ITC'99 benchmarks (Second Release) for experimental evaluation which as stated before, describe digital components of physical systems designed for various applications. Test sequences are derived for detecting the most known faults of the reference logic circuit using three different approaches to test derivation. Three widely used fault types such as stuck-at-faults, bridges, and faults which slightly modify the behavior of one gate are considered as possible faults of the reference behavior. The most interesting test sequences are short test sequences that can provide appropriate guarantees after testing, and thus, we experimentally study various approaches to the derivation of the so-called complete test suites which detect all fault types. In the first series of experiments, we compare two approaches for deriving complete test suites. In the first approach, a shortest test sequence is derived for testing each fault. In the second approach, a test sequence is pseudo-randomly generated by the use of an appropriate software for logic synthesis and verification (ABC system in our study) and thus, can be longer. However, after deleting sequences detecting the same set of faults, a test suite returned by the second approach is shorter. The latter underlines the fact that in many cases it is useless to spend `time and efforts' for deriving a shortest distinguishing sequence; it is better to use the test minimization afterwards. The performed experiments also show that the use of only randomly generated test sequences is not very efficient since such sequences do not detect all the faults of any type. After reaching the fault coverage around 70%, saturation is observed, and the fault coverage cannot be increased anymore. For deriving high quality short test suites, the approach that is the combination of randomly generated sequences together with sequences which are aimed to detect faults not detected by random tests, allows to reach the good fault coverage using shortest test sequences.
Comparative efficacy of antigen and antibody detection tests for human trichinellosis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ivanoska, D.; Cuperlovic, K.; Gamble, H.R.
1989-02-01
Sera collected from patients with suspected or confirmed exposure to Trichinella spiralis were tested for circulating parasite antigens and antiparasite antibodies. Using an immunoradiometric assay, excretory--secretory antigens from muscle-stage larvae of T. spiralis were detected in the sera of 47% of 62 patients with clinical trichinellosis and 13% of 39 patients without clinical signs but suspected of exposure to infected meat. In comparison, antibodies were detected using an indirect immunofluorescent test in the circulation of 100% of the 62 patients with clinical trichinellosis and 46% of the 39 patients with suspected exposure. The presence of antibodies specific to excretory-secretory productsmore » of T. spiralis muscle larvae was confirmed in the majority of the samples tested by a monoclonal antibody-based competitive inhibition assay. These results indicate that antibody detection is a more sensitive diagnostic method for human trichinellosis, but that antigen detection might be a useful confirmatory test because it is a direct demonstration of parasite products in the circulation.« less
Mwendwa, Fridah; Mbae, Cecilia K; Kinyua, Johnson; Mulinge, Erastus; Mburugu, Gitonga Nkanata; Njiru, Zablon K
2017-03-31
Entamoeba histolytica, the causative agent for amoebiasis is a considerable burden to population in the developing countries where it accounts for over 50 million infections. The tools for detection of amoebiasis are inadequate and diagnosis relies on microscopy which means a significant percent of cases remain undiagnosed. Moreover, tests formats that can be rapidly applied in rural endemic areas are not available. In this study, a loop-mediated isothermal test (LAMP) based on 18S small subunit ribosomal RNA gene was designed with extra reaction accelerating primers (stem primers) and compared with the published LAMP and PCR tests in detection of E. histolytica DNA in clinical samples. The stem LAMP test indicated shorter time to results by an average 11 min and analytical sensitivity of 10 -7 (~30 pg/ml) compared to the standard LAMP and PCR which showed sensitivities levels of 10 -5 (~3 ng/ml) and 10 -4 (~30 ng/ml) respectively using tenfold serial dilution of DNA. In the analysis of clinical specimens positive for Entamoeba spp. trophozoites and cysts using microscopy, the stem LAMP test detected E. histolytica DNA in 36/126, standard LAMP test 20/126 and PCR 17/126 cases respectively. There was 100% agreement in detection of the stem LAMP test product using fluorescence of SYTO-9 dye in real time machine, through addition of 1/10 dilution of SYBR ® Green I and electrophoresis in 2% agarose gel stained with ethidium bromide. The stem LAMP test developed in this study indicates potential towards detection of E. histolytica.
Fingerhuth, Stephanie M; Low, Nicola; Bonhoeffer, Sebastian; Althaus, Christian L
2017-07-26
Antibiotic resistance is threatening to make gonorrhoea untreatable. Point-of-care (POC) tests that detect resistance promise individually tailored treatment, but might lead to more treatment and higher levels of resistance. We investigate the impact of POC tests on antibiotic-resistant gonorrhoea. We used data about the prevalence and incidence of gonorrhoea in men who have sex with men (MSM) and heterosexual men and women (HMW) to calibrate a mathematical gonorrhoea transmission model. With this model, we simulated four clinical pathways for the diagnosis and treatment of gonorrhoea: POC test with (POC+R) and without (POC-R) resistance detection, culture and nucleic acid amplification tests (NAATs). We calculated the proportion of resistant infections and cases averted after 5 years, and compared how fast resistant infections spread in the populations. The proportion of resistant infections after 30 years is lowest for POC+R (median MSM: 0.18%, HMW: 0.12%), and increases for culture (MSM: 1.19%, HMW: 0.13%), NAAT (MSM: 100%, HMW: 99.27%), and POC-R (MSM: 100%, HMW: 99.73%). Per 100 000 persons, NAAT leads to 36 366 (median MSM) and 1228 (median HMW) observed cases after 5 years. Compared with NAAT, POC+R averts more cases after 5 years (median MSM: 3353, HMW: 118). POC tests that detect resistance with intermediate sensitivity slow down resistance spread more than NAAT. POC tests with very high sensitivity for the detection of resistance are needed to slow down resistance spread more than by using culture. POC with high sensitivity to detect antibiotic resistance can keep gonorrhoea treatable longer than culture or NAAT. POC tests without reliable resistance detection should not be introduced because they can accelerate the spread of antibiotic-resistant gonorrhoea.
The effect of coaching on the simulated malingering of memory impairment.
Rüsseler, Jascha; Brett, Alexandra; Klaue, Ulrike; Sailer, Michael; Münte, Thomas F
2008-10-07
Detecting malingering or exaggeration of impairments in brain function after traumatic brain injury is of increasing importance in neuropsychological assessment. Lawyers involved in brain injury litigation cases routinely coach their clients how to approach neuropsychological testing to their advantage. Thus, it is important to know how robust assessment methods are with respect to symptom malingering or exaggeration. The influence of different coaching methods on the simulated malingering of memory impairments is investigated in neurologically healthy participants using the Short-Term-Memory Test from the Bremer Symptom-Validierung (STM-BSV). Cut-offs were derived from patients with mild to severe traumatic brain injury. For comparison purposes, the German adaptation of the Rey Auditory Verbal Learning Test (AVLT), and the Rey 15 Items Test (FIT) were additionally administered. Four groups of neurologically healthy subjects were instructed to (1) perform as best as they can, (2) simulate brain injury, (3) simulate brain injury and received additional information about the sequelae of head trauma, (4) simulate brain injury and received additional information on how to avoid detection. Furthermore, a group of patients with mild to severe closed head injury performed the tests with best effort. The naïve simulator and the symptom coached groups were the easiest to detect, whereas the symptom plus test coached group was the hardest to detect. The AVLT and the FIT were not suited to detect simulators (sensitivities from 0% to 50.8% at 75% specificity) whereas the STM-BSV detected simulators with 67% - 88% sensitivity at a specificity of 73%. However, the STM-BSV was not robust to coaching. The present investigation shows that symptom validity testing as implemented in the BSV-STM is one clinically useful element in the detection of memory malingering. However, clinicians have to be aware that coaching influences performance in the test.
Palmer, Kendra L; Wood, Kelly E; Krasowski, Matthew D
2017-04-01
The objective of this study was to compare detection rates of newborn drug exposure at an academic medical center transitioning from meconium to umbilical cord tissue toxicology testing. We performed an Institutional Review Board-approved retrospective chart review on all newborns (n=2072) for whom newborn drug testing was ordered at our academic medical center between June 2012 and August 2015 (in August 2013, umbilical cord tissue became the preferred specimen). Meconium toxicology testing was positive for at least one compound in 221 cases (21.3% of 1037 total specimens), with non-medical drug use identified in 85 cases (8.2%). Umbilical cord tissue toxicology testing was positive for at least one compound in 302 cases (29.2%), with non-medical drug use identified in 107 cases (10.3%). Of the cases involving non-medical drug use, the most common compounds detected were tetrahydrocannabinol and amphetamines. Non-medical drug use did not differ significantly between meconium and umbilical cord tissue, either as a total or for classes of drugs such as amphetamines, cannabinoids, and opiates. Maternal non-medical use of tramadol (not tested for in meconium) was identified in 5 cases (0.4%). There were significant differences in rate of detection of iatrogenic medications. Specifically, morphine, lorazepam, phenobarbital, and codeine were more commonly detected in meconium, while oxycodone was more commonly detected in umbilical cord tissue. Umbilical cord tissue toxicology testing yielded a similar detection rate compared to meconium testing. The use of umbilical cord tissue avoids detection of medications given to the neonate prior to meconium collection. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
More, S J; Cameron, A R; Strain, S; Cashman, W; Ezanno, P; Kenny, K; Fourichon, C; Graham, D
2015-08-01
As part of a broader control strategy within herds known to be infected with Mycobacterium avium ssp. paratuberculosis (MAP), individual animal testing is generally conducted to identify infected animals for action, usually culling. Opportunities are now available to quantitatively compare different testing strategies (combinations of tests) in known infected herds. This study evaluates the effectiveness, cost, and cost-effectiveness of different testing strategies to identify infected animals at a single round of testing within dairy herds known to be MAP infected. A model was developed, taking account of both within-herd infection dynamics and test performance, to simulate the use of different tests at a single round of testing in a known infected herd. Model inputs included the number of animals at different stages of infection, the sensitivity and specificity of each test, and the costs of testing and culling. Testing strategies included either milk or serum ELISA alone or with fecal culture in series. Model outputs included effectiveness (detection fraction, the proportion of truly infected animals in the herd that are successfully detected by the testing strategy), cost, and cost-effectiveness (testing cost per true positive detected, total cost per true positive detected). Several assumptions were made: MAP was introduced with a single animal and no management interventions were implemented to limit within-herd transmission of MAP before this test. In medium herds, between 7 and 26% of infected animals are detected at a single round of testing, the former using the milk ELISA and fecal culture in series 5 yr after MAP introduction and the latter using fecal culture alone 15 yr after MAP introduction. The combined costs of testing and culling at a single round of testing increases with time since introduction of MAP infection, with culling costs being much greater than testing costs. The cost-effectiveness of testing varied by testing strategy. It was also greater at 5 yr, compared with 10 or 15 yr, since MAP introduction, highlighting the importance of early detection. Future work is needed to evaluate these testing strategies in subsequent rounds of testing as well as accounting for different herd dynamics and different levels of herd biocontainment. Copyright © 2015 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Automated High-Speed Video Detection of Small-Scale Explosives Testing
NASA Astrophysics Data System (ADS)
Ford, Robert; Guymon, Clint
2013-06-01
Small-scale explosives sensitivity test data is used to evaluate hazards of processing, handling, transportation, and storage of energetic materials. Accurate test data is critical to implementation of engineering and administrative controls for personnel safety and asset protection. Operator mischaracterization of reactions during testing contributes to either excessive or inadequate safety protocols. Use of equipment and associated algorithms to aid the operator in reaction determination can significantly reduce operator error. Safety Management Services, Inc. has developed an algorithm to evaluate high-speed video images of sparks from an ESD (Electrostatic Discharge) machine to automatically determine whether or not a reaction has taken place. The algorithm with the high-speed camera is termed GoDetect (patent pending). An operator assisted version for friction and impact testing has also been developed where software is used to quickly process and store video of sensitivity testing. We have used this method for sensitivity testing with multiple pieces of equipment. We present the fundamentals of GoDetect and compare it to other methods used for reaction detection.
Defense Advanced Research Projects Agency Technology Transition
1997-01-01
detection of nuclear testing in space , navigation, meteo- rological monitoring, and communication. These early activities were transferred to the Military...used to detect nuclear tests in space and in the atmosphere as part of the overall basis for verification of a future nuclear test ban treaty. The first...background data to detect nuclear explosions taking place in space , and eventually also in the earth’s atmosphere. The program developed x-ray, neutron
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Zhaohui; Wang, Ying; Wang, Jun
2010-08-15
A portable fluorescence biosensor with rapid and ultrasensitive response for trace protein has been built up with quantum dots and lateral flow test strip. The superior signal brightness and high photostability of quantum dots are combined with the promising advantages of lateral flow test strip and resulted in high sensitivity, selectivity and speedy for protein detection. Nitrated ceruloplasmin, a significant biomarker for cardiovascular disease, lung cancer and stress response to smoking, was used as model protein to demonstrate the good performances of this proposed Qdot-based lateral flow test strip. Quantitative detection of nitrated ceruloplasmin was realized by recording the fluorescencemore » intensity of quantum dots captured on the test line. Under optimal conditions, this portable fluorescence biosensor displays rapid responses for nitrated ceruloplasmin in wide dynamic range with a detection limit of 0.1ng/mL (S/N=3). Furthermore, the biosensor was successfully utilized for spiked human plasma sample detection with the concentration as low as 1ng/mL. The results demonstrate that the quantum dot-based lateral flow test strip is capable for rapid, sensitive, and quantitative detection of nitrated ceruloplasmin and hold a great promise for point-of-care and in field analysis of other protein biomarkers.« less
Cho, Sun-Joo; Preacher, Kristopher J; Bottge, Brian A
2015-11-01
Multilevel modeling (MLM) is frequently used to detect group differences, such as an intervention effect in a pre-test-post-test cluster-randomized design. Group differences on the post-test scores are detected by controlling for pre-test scores as a proxy variable for unobserved factors that predict future attributes. The pre-test and post-test scores that are most often used in MLM are summed item responses (or total scores). In prior research, there have been concerns regarding measurement error in the use of total scores in using MLM. To correct for measurement error in the covariate and outcome, a theoretical justification for the use of multilevel structural equation modeling (MSEM) has been established. However, MSEM for binary responses has not been widely applied to detect intervention effects (group differences) in intervention studies. In this article, the use of MSEM for intervention studies is demonstrated and the performance of MSEM is evaluated via a simulation study. Furthermore, the consequences of using MLM instead of MSEM are shown in detecting group differences. Results of the simulation study showed that MSEM performed adequately as the number of clusters, cluster size, and intraclass correlation increased and outperformed MLM for the detection of group differences.
Cardoso, Débora Morais; Gilio, Alfredo Elias; Hsin, Shieh Huei; Machado, Beatriz Marcondes; de Paulis, Milena; Lotufo, João Paulo B; Martinez, Marina Baquerizo; Grisi, Sandra Josefina E
2013-01-01
To evaluate the impact of the routine use of rapid antigen detection test in the diagnosis and treatment of acute pharyngotonsillitis in children. This is a prospective and observational study, with a protocol compliance design established at the Emergency Unit of the University Hospital of Universidade de São Paulo for the care of children and adolescents diagnosed with acute pharyngitis. 650 children and adolescents were enrolled. Based on clinical findings, antibiotics would be prescribed for 389 patients (59.8%); using the rapid antigen detection test, they were prescribed for 286 patients (44.0%). Among the 261 children who would not have received antibiotics based on the clinical evaluation, 111 (42.5%) had positive rapid antigen detection test. The diagnosis based only on clinical evaluation showed 61.1% sensitivity, 47.7% specificity, 44.9% positive predictive value, and 57.5% negative predictive value. The clinical diagnosis of streptococcal pharyngotonsillitis had low sensitivity and specificity. The routine use of rapid antigen detection test led to the reduction of antibiotic use and the identification of a risk group for complications of streptococcal infection, since 42.5% positive rapid antigen detection test patients would not have received antibiotics based only on clinical diagnosis.
Commercial Grade Item (CGI) Dedication for Leak Detection Relays
DOE Office of Scientific and Technical Information (OSTI.GOV)
KOCH, M.R.; JOHNS, B.R.
1999-12-21
This Test Plan provides a test method to dedicate the leak detection relays used on the new Pumping and Instrumentation Control (PIC) skids. The new skids are fabricated on-site. The leak detection system is a safety class system per the Authorization Basis.
Commercial Grade Item (CGI) Dedication for Leak Detection Relays
DOE Office of Scientific and Technical Information (OSTI.GOV)
KOCH, M.R.
2000-02-28
This Test Plan provides a test method to dedicate the leak detection relays used on the new Pumping Instrumentation and Control (PIC) skids. The new skids are fabricated on-site. The leak detection system is a safety class system per the Authorization Basis.
Commercial Grade Item (CGI) Dedication for Leak Detection Relays
DOE Office of Scientific and Technical Information (OSTI.GOV)
KOCH, M.R.
1999-08-11
This Test Plan provides a test method to dedicate the leak detection relays used on the new Pumping and Instrumentation Control (PIC) skids. The new skids are fabricated on-site. The leak detection system is a safety class system per the Authorization Basis.
Commercial Grade Item (CGI) Dedication for Leak Detection Relays
DOE Office of Scientific and Technical Information (OSTI.GOV)
JOHNS, B.R.
1999-05-05
This Test Plan provides a test method to dedicate the leak detection relays used on the new Pumping and Instrumentation Control (PIC) skids. The new skids are fabricated on-site. The leak detection system is a safety class system per the Authorization Basis.
Commercial Grade Item (CGI) Dedication for Leak Detection Relays
DOE Office of Scientific and Technical Information (OSTI.GOV)
KOCH, M.R.
1999-10-26
This Test Plan provides a test method to dedicate the leak detection relays used on the new Pumping and Instrumentation Control (PIC) skids. The new skids are fabricated on-site. The leak detection system is a safety class system per the Authorization Basis.
Commercial Grade Item (CGI) Dedication for Leak Detection Relays
DOE Office of Scientific and Technical Information (OSTI.GOV)
JOHNS, B.R.; KOCH, M.R.
2000-01-28
This Test Plan provides a test method to dedicate the leak detection relays used on the new Pumping Instrumentation and Control (PIC) skids. The new skids are fabricated on-site. The leak detection system is a safety class system per the Authorization Basis.
32 CFR 634.36 - Detection, apprehension, and testing of intoxicated drivers.
Code of Federal Regulations, 2011 CFR
2011-07-01
... THE ARMY (CONTINUED) LAW ENFORCEMENT AND CRIMINAL INVESTIGATIONS MOTOR VEHICLE TRAFFIC SUPERVISION Traffic Supervision § 634.36 Detection, apprehension, and testing of intoxicated drivers. (a) Law enforcement personnel usually detect drivers under the influence of alcohol or other drugs by observing...
32 CFR 634.36 - Detection, apprehension, and testing of intoxicated drivers.
Code of Federal Regulations, 2010 CFR
2010-07-01
... THE ARMY (CONTINUED) LAW ENFORCEMENT AND CRIMINAL INVESTIGATIONS MOTOR VEHICLE TRAFFIC SUPERVISION Traffic Supervision § 634.36 Detection, apprehension, and testing of intoxicated drivers. (a) Law enforcement personnel usually detect drivers under the influence of alcohol or other drugs by observing...
Nitromethane K-9 Detection Limit
DOE Office of Scientific and Technical Information (OSTI.GOV)
Strobel, R; Kury, J
2003-08-29
The Bureau of Alcohol, Tobacco and Firearms (ATF) trains canine/handler teams to detect explosives for government and other agencies worldwide. After completing the training program the teams are tested on an array containing explosives and numerous other samples designed to distract a canine. Passing this test results in a team's certification. These teams can be considered as ''detection instruments'' freshly calibrated just before leaving the ''factory''. Using these teams to examine special experimental arrays immediately following certification can lead to a better understanding of a canine's detection capabilities. Forty-one of these ''detection instruments'' were used in four test series withmore » arrays containing dilute nitromethane-in-water solutions. (The canines had been trained on the amount of nitromethane vapor in equilibrium with the undiluted liquid explosive.) By diluting liquid nitromethane with water, the amount of explosive vapor can be reduced many orders of magnitude to test the lower limit of the canine's nitromethane vapor detection response. The results are presented in this paper.« less
A dedicated on-line detecting system for auto air dryers
NASA Astrophysics Data System (ADS)
Shi, Chao-yu; Luo, Zai
2013-10-01
According to the correlative automobile industry standard and the requirements of manufacturer, this dedicated on-line detecting system is designed against the shortage of low degree automatic efficiency and detection precision of auto air dryer in the domestic. Fast automatic detection is achieved by combining the technology of computer control, mechatronics and pneumatics. This system can detect the speciality performance of pressure regulating valve and sealability of auto air dryer, in which online analytical processing of test data is available, at the same time, saving and inquiring data is achieved. Through some experimental analysis, it is indicated that efficient and accurate detection of the performance of auto air dryer is realized, and the test errors are less than 3%. Moreover, we carry out the type A evaluation of uncertainty in test data based on Bayesian theory, and the results show that the test uncertainties of all performance parameters are less than 0.5kPa, which can meet the requirements of operating industrial site absolutely.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Raj, Sunny; Jha, Sumit Kumar; Pullum, Laura L.
Validating the correctness of human detection vision systems is crucial for safety applications such as pedestrian collision avoidance in autonomous vehicles. The enormous space of possible inputs to such an intelligent system makes it difficult to design test cases for such systems. In this report, we present our tool MAYA that uses an error model derived from a convolutional neural network (CNN) to explore the space of images similar to a given input image, and then tests the correctness of a given human or object detection system on such perturbed images. We demonstrate the capability of our tool on themore » pre-trained Histogram-of-Oriented-Gradients (HOG) human detection algorithm implemented in the popular OpenCV toolset and the Caffe object detection system pre-trained on the ImageNet benchmark. Our tool may serve as a testing resource for the designers of intelligent human and object detection systems.« less
Evaluation of Polymerase Chain Reaction for Detecting Coliform Bacteria in Drinking Water Sources.
Isfahani, Bahram Nasr; Fazeli, Hossein; Babaie, Zeinab; Poursina, Farkhondeh; Moghim, Sharareh; Rouzbahani, Meisam
2017-01-01
Coliform bacteria are used as indicator organisms for detecting fecal pollution in water. Traditional methods including microbial culture tests in lactose-containing media and enzyme-based tests for the detection of β-galactosidase; however, these methods are time-consuming and less specific. The aim of this study was to evaluate polymerase chain reaction (PCR) for detecting coliform. Totally, 100 of water samples from Isfahan drinking water source were collected. Coliform bacteria and Escherichia coli were detected in drinking water using LacZ and LamB genes in PCR method performed in comparison with biochemical tests for all samples. Using phenotyping, 80 coliform isolates were found. The results of the biochemical tests illustrated 78.7% coliform bacteria and 21.2% E. coli . PCR results for LacZ and LamB genes were 67.5% and 17.5%, respectively. The PCR method was shown to be an effective, sensitive, and rapid method for detecting coliform and E. coli in drinking water from the Isfahan drinking water sources.
Pathak, Neha; Dodds, Julie; Khan, Khalid
2014-01-01
Objective To determine the accuracy of testing for human papillomavirus (HPV) DNA in urine in detecting cervical HPV in sexually active women. Design Systematic review and meta-analysis. Data sources Searches of electronic databases from inception until December 2013, checks of reference lists, manual searches of recent issues of relevant journals, and contact with experts. Eligibility criteria Test accuracy studies in sexually active women that compared detection of urine HPV DNA with detection of cervical HPV DNA. Data extraction and synthesis Data relating to patient characteristics, study context, risk of bias, and test accuracy. 2×2 tables were constructed and synthesised by bivariate mixed effects meta-analysis. Results 16 articles reporting on 14 studies (1443 women) were eligible for meta-analysis. Most used commercial polymerase chain reaction methods on first void urine samples. Urine detection of any HPV had a pooled sensitivity of 87% (95% confidence interval 78% to 92%) and specificity of 94% (95% confidence interval 82% to 98%). Urine detection of high risk HPV had a pooled sensitivity of 77% (68% to 84%) and specificity of 88% (58% to 97%). Urine detection of HPV 16 and 18 had a pooled sensitivity of 73% (56% to 86%) and specificity of 98% (91% to 100%). Metaregression revealed an increase in sensitivity when urine samples were collected as first void compared with random or midstream (P=0.004). Limitations The major limitations of this review are the lack of a strictly uniform method for the detection of HPV in urine and the variation in accuracy between individual studies. Conclusions Testing urine for HPV seems to have good accuracy for the detection of cervical HPV, and testing first void urine samples is more accurate than random or midstream sampling. When cervical HPV detection is considered difficult in particular subgroups, urine testing should be regarded as an acceptable alternative. PMID:25232064
Reybroeck, W.; Ooghe, S.; De Brabander, H.F.; Daeseleire, E.
2010-01-01
The 2-min protocol (1 + 1) for the βeta-s.t.a.r. (manufactured by Neogen Corporation, Lansing, MI, USA) was validated at the Technology and Food Science Unit of the Institute for Agricultural and Fisheries Research according to Commission Decision 2002/657/EC. The test was very selective for the group of β-lactam compounds: the only interference found was by clavulanic acid at 2500 μg kg−1 and above. The modified protocol (βeta-s.t.a.r. 1 + 1) detected all β-lactams with a maximum residue limit (MRL) in milk, but not all these compounds were detected at their respective MRL. The detection of cefalexin (detection capability = 6000 μg kg−1; MRL = 100 μg kg−1) and penethamate (detection capability = 80 μg kg−1; MRL = 4 μg kg−1) was especially poor, and also ceftiofur was only detected from 500 μg kg−1 (MRL = 100 μg kg−1). The repeatability of the reader and of the test was very good. The test was very robust: test results were not significantly influenced by small changes in the test protocol, by the milk composition or by the type of milk. The test was also suitable to test the milk of animal species other than cow. Favourable results were obtained in testing monitoring samples, in two national ring trials, and in an international proficiency test. The βeta-s.t.a.r. 1 + 1 is a very fast, simple, and reliable test that could be used at the farm level to prevent tanker milk contamination by β-lactams. PMID:20512709
Babbur, Vijayalakshmi; Lees, Christoph C; Goodburn, Sandra F; Morris, Nigel; Breeze, Andrew C G; Hackett, Gerald A
2005-06-01
To determine detection and false-positive rates for trisomy 21 using two-stage combined nuchal translucency (NT) and triple testing, whilst disclosing abnormal nuchal measurements at the scan. A prospective audit in a UK women's hospital, of 3188 women with singleton pregnancies, requesting screening for trisomy 21. Median age was 37 years (range 19-46). Women were offered NT screening at 11 to 14 weeks. Those with NT > or =3 mm were offered chorionic villus sampling. Those declining CVS, and those with NT <3 mm, were offered early triple tests. Women with a term combined risk of trisomy 21 > or = 1:250, based on age, NT, and triple test results were offered amniocentesis. Using a 3-mm NT 'cut-off' identified 16/25 cases of trisomy 21 (64%; 95% CI 38.8, 78.9). Of 2725 women who had a combined nuchal plus triple test assessment, 79 (2.6%) had a > or = 1:250 term risk of trisomy 21. Forty (1.3%) had amniocentesis identifying 6/9 remaining cases (67%:95% CI:27.9, 92.5). Overall, the detection rate was 88% (95% CI:68.8, 97.5) for a 4.8% FPR. For the screened population, to achieve an 88% detection rate using the triple test alone, the predicted FPR would be 20%. Conversely, for an FPR of 4.8% using the triple test alone, the detection rate would be only 60%. In a high-risk group, the combination of NT with triple test offers detection of trisomy 21 at least equivalent to either test, while allowing disclosure of an abnormal NT at the scan and reducing the FPR. Importantly, the FPR is less than 5%, considerably lower than expected for triple test alone for this population.
Integrating Oil Debris and Vibration Gear Damage Detection Technologies Using Fuzzy Logic
NASA Technical Reports Server (NTRS)
Dempsey, Paula J.; Afjeh, Abdollah A.
2002-01-01
A diagnostic tool for detecting damage to spur gears was developed. Two different measurement technologies, wear debris analysis and vibration, were integrated into a health monitoring system for detecting surface fatigue pitting damage on gears. This integrated system showed improved detection and decision-making capabilities as compared to using individual measurement technologies. This diagnostic tool was developed and evaluated experimentally by collecting vibration and oil debris data from fatigue tests performed in the NASA Glenn Spur Gear Fatigue Test Rig. Experimental data were collected during experiments performed in this test rig with and without pitting. Results show combining the two measurement technologies improves the detection of pitting damage on spur gears.
Testing the system detection unit for measuring solid minerals bulk density
NASA Astrophysics Data System (ADS)
Voytyuk, I. N.; Kopteva, A. V.
2017-10-01
The paper provides a brief description of the system for measuring flux per volume of solid minerals via example of mineral coal. The paper discloses the operational principle of the detection unit. The paper provides full description of testing methodology, as well as practical implementation of the detection unit testing. This paper describes the removal of two data arrays via the channel of scattered anddirect radiation for the detection units of two generations. This paper describes Matlab software to determine the statistical characteristics of the studied objects. The mean value of pulses per cycles, and pulse counting inaccuracy relatively the mean value were determined for the calculation of the stability account of the detection units.
Zhong, C Q; He, N; Hua, M Q; Wei, X D; Ma, D X; Ji, C Y
2016-09-14
Objective: To set internal quality control system of BCR-ABL (P210) transcript levels for real-time quantitative PCR (RQ-PCR). Methods: Using K562 cells and HL-60 cells, we prepared high- and low-level BCR-ABL internal quality control substance. The BCR-ABL (P210) transcript levels of internal quality control substance have been determined for 184 times together with clinical samples from August 2013 to October 2015. The slope rate, intercept and correlation coefficient of standard curve were calculated according to different reagent lots (lots number 20130303, 20131212, 20140411 and 20150327 are called R1、R2、R3 and R4 for short respectively), and the detection results of quality control substance were calculated according to different reagent lots and quality control substance lots (lots number 20130725, 20140611 are called Q1、Q2 for short respectively). Then the results were analyzed by Levey-Jennings quality control chart combined with Westgard multi-rules theory. Results: ①We analyzed the slope rate and intercept of standard curve. Fifty-three times of the R1 reagent detection, 80 times of the R3 reagent detection and 14 times of the R4 reagent detection were all under control. For 37 times detection of R2 reagent, the slope rate was out of control for 6 times. It was lower than x - s for the 2-8 tests and upper the average for the 12-37 tests. The intercept was out of control for 9 times, upper the x + s for the 1-8 tests and lower the average for the 12-37 tests. ② According to the detection results of quality control substance, for Q1 quality control substance, 49 tests by R1 reagent were under control, and 1 out of 23 tests by R2 reagent was out of control. For Q2 quality control substance, 14 tests by R2 reagent detection, 72 tests by R3 reagent detection and 14 tests by R4 reagent were all under control. Conclusion: The preparation of high- and low-level quality control substance using K562 and HL-60 cells was convenient and the detection results were reliable and stable. The application of quality control substance combined with slope rate and intercept in the internal quality control may contribute to quality assurance for quantitative detection of BCR-ABL (P210) transcript levels.
Safety and clinical performance of acoustic reflex tests.
Hunter, L L; Ries, D T; Schlauch, R S; Levine, S C; Ward, W D
1999-12-01
Safety and effectiveness of acoustic reflex tests are important issues because these tests are widely applied to screen for retrocochlear pathology. Previous studies have reported moderately high sensitivity and specificity for detection of acoustic neuroma. However, there have been reports of possible iatrogenic hearing loss resulting from acoustic reflex threshold (ART) and decay (ARD) tests. This study assessed safety and clinical performance of ART tests for detection of acoustic neuroma. We report a case in which ARD testing resulted in a significant bilateral permanent threshold shift. This case was the impetus for us to investigate the clinical utility of ART and ARD tests. We analyzed sensitivity and specificity of ART, as well as asymmetry in pure-tone thresholds (PTT) for detection of acoustic neuroma in 56 tumor and 108 non-tumor ears. Sensitivity and specificity were higher for PTT asymmetry than for ART. Ipsilateral ART at 1000 Hz had poor sensitivity and specificity for detection of acoustic neuroma, and involves some potential risk to residual hearing for presentation levels higher than 115 dB SPL. Approximately half of the acoustic neuroma group had ipsilateral ARTs that would require administration of ARD tests at levels exceeding 115 dB SPL. Therefore, we conclude that PTT asymmetry is a more effective test for detection of acoustic neuroma, and involves no risk to residual hearing. Future studies of contralateral reflex threshold and ARD in combination with PTT asymmetry are recommended.
ERIC Educational Resources Information Center
Ferrara, Steve
2017-01-01
Test security is not an end in itself; it is important because we want to be able to make valid interpretations from test scores. In this article, I propose a framework for comprehensive test security systems: prevention, detection, investigation, and resolution. The article discusses threats to test security, roles and responsibilities, rigorous…
Wolf, Heinz; Stauffer, Tony; Chen, Shu-Chen Y; Lee, Yoojin; Forster, Ronald; Ludzinski, Miron; Kamat, Madhav; Mulhall, Brian; Guazzo, Dana Morton
2009-01-01
Part 1 of this series demonstrated that a container closure integrity test performed according to ASTM F2338-09 Standard Test Method for Nondestructive Detection of Leaks in Packages by Vacuum Decay Method using a VeriPac 325/LV vacuum decay leak tester by Packaging Technologies & Inspection, LLC (PTI) is capable of detecting leaks > or = 5.0 microm (nominal diameter) in rigid, nonporous package systems, such as prefilled glass syringes. The current study compared USP, Ph.Eur. and ISO dye ingress integrity test methods to PTI's vacuum decay technology for the detection of these same 5-, 10-, and 15-microm laser-drilled hole defects in 1-mL glass prefilled syringes. The study was performed at three test sites using several inspectors and a variety of inspection conditions. No standard dye ingress method was found to reliably identify all holed syringes. Modifications to these standard dye tests' challenge conditions increased the potential for dye ingress, and adjustments to the visual inspection environment improved dye ingress detection. However, the risk of false positive test results with dye ingress tests remained. In contrast, the nondestructive vacuum decay leak test method reliably identified syringes with holes > or = 5.0 microm.
Study of acoustic emission during mechanical tests of large flight weight tank structure
NASA Technical Reports Server (NTRS)
Mccauley, B. O.; Nakamura, Y.; Veach, C. L.
1973-01-01
A PPO-insulated, flight-weight, subscale, aluminum tank was monitored for acoustic emissions during a proof test and during 100 cycles of environmental test simulating space flights. The use of a combination of frequency filtering and appropriate spatial filtering to reduce background noise was found to be sufficient to detect acoustic emission signals of relatively small intensity expected from subcritical crack growth in the structure. Several emission source locations were identified, including the one where a flaw was detected by post-test x-ray inspections. For most source locations, however, post-test inspections did not detect flaws; this was partially attributed to the higher sensitivity of the acoustic emission technique than any other currently available NDT method for detecting flaws. For these non-verifiable emission sources, a problem still remains in correctly interpreting observed emission signals.
Acoustic vibration test detects intermittent electrical discontinuities
NASA Technical Reports Server (NTRS)
Grieve, S. M.; Roberts, D. E.
1970-01-01
Nondestructive test method detects faulty electrical connections in inaccessible or hidden portions of electronic harness assemblies and connectors. Method employs readily available commercial equipment.
COMPARISON OF TWO METHODS FOR DETECTION OF GIARDIA CYSTS AND CRYTOSPORIDIUM OOCYSTS IN WATER
The steps of two immunofluorescent-antibody-based detection methods were evaluated for their efficiencies in detecting Giardia cysts and Cryptosporidium oocysts. The two methods evaluated were the American Society for Testing and Materials proposed test method for Giardia cysts a...
Marihuana contact test, evaluation and development
DOT National Transportation Integrated Search
1976-02-01
A colorimetric swab test for detecting human contact with marihuana was evaluated. The test was found to be capable of detecting only 83% of marihuana smokers immediately after smoking and was also demonstrated to be subject to a wide range of possib...
Herbst de Cortina, Sasha; Bristow, Claire C; Humphries, Romney; Vargas, Silver Keith; Konda, Kelika A; Caceres, Carlos F; Klausner, Jeffrey D
2017-07-01
Dual point-of-care tests for antibodies to human immunodeficiency virus (HIV) and Treponema pallidum allow for same-day testing and treatment and have been demonstrated to be cost-effective in preventing the adverse outcomes of HIV infection and syphilis. By recording and transmitting data as they are collected, electronic readers address challenges related to the decentralization of point-of-care testing. We evaluated a smartphone-based electronic reader using 201 sera tested with 2 dual rapid tests for detection of antibodies to HIV and T. pallidum in Los Angeles, USA, and Lima, Peru. Tests were read both visually and with the electronic reader. Enzyme immunoassay followed by Western blot and T. pallidum particle agglutination were the reference tests for HIV and T. pallidum, respectively. The sensitivities of the 2 rapid tests for detection of HIV were 94.1% and 97.0% for electronic readings. Both tests had a specificity of 100% for detection of HIV by electronic reading. The sensitivities of the 2 rapid tests for detection of T. pallidum were 86.5% and 92.4% for electronic readings. The specificities for detection of T. pallidum were 99.1% and 99.0% by electronic reading. There were no significant differences between the accuracies of visual and electronic readings, and the performance did not differ between the 2 study sites. Our results show the electronic reader to be a promising option for increasing the use of point-of-care testing programs.
SUMMARY OF ACCIDENTAL RELEASES OF RADIOACTIVITY DETECTED OFF THE NEVADA TEST SITE, 1963-1986
Of the more than 450 underground nuclear explosives tests conducted at the Nevada Test Site from August 1963 (signing of the Limited Test Ban Treaty) through the end of 1986, only 23 accidentally released radioactivity that was detectable beyond the boundary of the NTS. Of these ...
Application of Bayesian Methods for Detecting Fraudulent Behavior on Tests
ERIC Educational Resources Information Center
Sinharay, Sandip
2018-01-01
Producers and consumers of test scores are increasingly concerned about fraudulent behavior before and during the test. There exist several statistical or psychometric methods for detecting fraudulent behavior on tests. This paper provides a review of the Bayesian approaches among them. Four hitherto-unpublished real data examples are provided to…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chiaro, PJ
The Environmental Effects Laboratory of the Engineering Science and Technology Division of Oak Ridge National Laboratory performed a series of tests to further evaluate and characterize the radiological response of a ''Cricket'' radiation detection system. The Cricket, manufactured by Rad/Comm Systems Corporation of Ontario, Canada, is designed to detect radioactive material that may be contained in scrap metal. The Cricket's detection unit is designed to be mounted to the base of a grappler, allowing it to monitor material while the material is being held by the grappler tines. The Cricket was tested for background stability, energy response, spherical response, surfacemore » uniformity, angular dependence, and alarm actuation. Some of these tests were repeated from a prior test of a Cricket at the Environmental Effects Laboratory as reported in ORNL/TM-2002/94. Routine environmental tests--normal temperature and relatively humidity--were also performed as part of this testing process. Overall, the Cricket performed well during the testing process. The design of the instrument and the inherent photon energy of the radionuclides had some affect on portions of the tests but do not detract from the value-added benefits of the Cricket's detection capabilities.« less
Crawshaw, Timothy R; Chanter, Jeremy I; McGoldrick, Adrian; Line, Kirsty
2014-02-07
Cases of Mycobacterium bovis infection South American camelids have been increasing in Great Britain. Current antemortem immunological tests have some limitations. Cases at post mortem examination frequently show extensive pathology. The feasibility of detecting Mycobacterium bovis DNA in clinical samples was investigated. A sensitive extraction methodology was developed and used on nasal swabs and faeces taken post-mortem to assess the potential for a PCR test to detect Mycobacterium bovis in clinical samples. The gross pathology of the studied South American camelids was scored and a significantly greater proportion of South American camelids with more severe pathology were positive in both the nasal swab and faecal PCR tests. A combination of the nasal swab and faecal PCR tests detected 63.9% of all the South American camelids with pathology that were tested. The results suggest that antemortem diagnosis of Mycobacterium bovis in South American camelids may be possible using a PCR test on clinical samples, however more work is required to determine sensitivity and specificity, and the practicalities of applying the test in the field.
The accuracy of confrontation visual field test in comparison with automated perimetry.
Johnson, L. N.; Baloh, F. G.
1991-01-01
The accuracy of confrontation visual field testing was determined for 512 visual fields using automated static perimetry as the reference standard. The sensitivity of confrontation testing excluding patchy defects was 40% for detecting anterior visual field defects, 68.3% for posterior defects, and 50% for both anterior and posterior visual field defects combined. The sensitivity within each group varied depending on the type of visual field defect encountered. Confrontation testing had a high sensitivity (75% to 100%) for detecting altitudinal visual loss, central/centrocecal scotoma, and homonymous hemianopsia. Confrontation testing was fairly insensitive (20% to 50% sensitivity) for detecting arcuate scotoma and bitemporal hemianopsia. The specificity of confrontation testing was high at 93.4%. The high positive predictive value (72.6%) and negative predictive value (75.7%) would indicate that visual field defects identified during confrontation testing are often true visual field defects. However, the many limitations of confrontation testing should be remembered, particularly its low sensitivity for detecting visual field loss associated with parasellar tumors, glaucoma, and compressive optic neuropathies. PMID:1800764
The Gap Detection Test: Can It Be Used to Diagnose Tinnitus?
Boyen, Kris; Başkent, Deniz; van Dijk, Pim
2015-01-01
Animals with induced tinnitus showed difficulties in detecting silent gaps in sounds, suggesting that the tinnitus percept may be filling the gap. The main purpose of this study was to evaluate the applicability of this approach to detect tinnitus in human patients. The authors first hypothesized that gap detection would be impaired in patients with tinnitus, and second, that gap detection would be more impaired at frequencies close to the tinnitus frequency of the patient. Twenty-two adults with bilateral tinnitus, 20 age-matched and hearing loss-matched subjects without tinnitus, and 10 young normal-hearing subjects participated in the study. To determine the characteristics of the tinnitus, subjects matched an external sound to their perceived tinnitus in pitch and loudness. To determine the minimum detectable gap, the gap threshold, an adaptive psychoacoustic test was performed three times by each subject. In this gap detection test, four different stimuli, with various frequencies and bandwidths, were presented at three intensity levels each. Similar to previous reports of gap detection, increasing sensation level yielded shorter gap thresholds for all stimuli in all groups. Interestingly, the tinnitus group did not display elevated gap thresholds in any of the four stimuli. Moreover, visual inspection of the data revealed no relation between gap detection performance and perceived tinnitus pitch. These findings show that tinnitus in humans has no effect on the ability to detect gaps in auditory stimuli. Thus, the testing procedure in its present form is not suitable for clinical detection of tinnitus in humans.
Klein, Pamela W.; Messer, Lynne C.; Myers, Evan R.; Weber, David J.; Leone, Peter A.; Miller, William C.
2016-01-01
The impact of routine, opt-out HIV testing programs in clinical settings is inconclusive. The objective of this study was to estimate the impact of an expanded, routine HIV testing program in North Carolina sexually transmitted disease (STD) clinics on HIV testing and case detection. Adults aged 18–64 who received an HIV test in a North Carolina STD clinic July 1, 2005 through June 30, 2011 were included in this analysis, dichotomized at the date of implementation on November 1, 2007. HIV testing and case detection counts and rates were analyzed using interrupted time series analysis, and Poisson and multilevel logistic regression. Pre-intervention, 426 new HIV-infected cases were identified from 128,029 tests (0.33%), whereas 816 new HIV-infected cases were found from 274,745 tests post-intervention (0.30%). Pre-intervention, HIV testing increased by 55 tests per month (95% confidence interval [CI]: 41, 72), but only 34 tests per month (95% CI: 26, 42) post-intervention. Increases in HIV testing rates were most pronounced in females and non-Hispanic whites. A slight pre-intervention decline in case detection was mitigated by the intervention (mean difference [MD]=0.01; 95% CI: −0.02, 0.05). Increases in case detection rates were observed among females and non-Hispanic blacks. The impact of a routine HIV screening in North Carolina STD clinics was marginal, with the greatest benefit among persons not traditionally targeted for HIV testing. The use of a pre-intervention comparison period identified important temporal trends that otherwise would have been ignored. PMID:24825338
Quantitative PCR detection of Batrachochytrium dendrobatidis DNA from sediments and water
Kirshtein, Julie D.; Anderson, Chauncey W.; Wood, J.S.; Longcore, Joyce E.; Voytek, Mary A.
2007-01-01
The fungal pathogen Batrachochytrium dendrobatidis (Bd) causes chytridiomycosis, a disease implicated in amphibian declines on 5 continents. Polymerase chain reaction (PCR) primer sets exist with which amphibians can be tested for this disease, and advances in sampling techniques allow non-invasive testing of animals. We developed filtering and PCR based quantitative methods by modifying existing PCR assays to detect Bd DNA in water and sediments, without the need for testing amphibians; we tested the methods at 4 field sites. The SYBR based assay using Boyle primers (SYBR/Boyle assay) and the Taqman based assay using Wood primers performed similarly with samples generated in the laboratory (Bd spiked filters), but the SYBR/Boyle assay detected Bd DNA in more field samples. We detected Bd DNA in water from 3 of 4 sites tested, including one pond historically negative for chytridiomycosis. Zoospore equivalents in sampled water ranged from 19 to 454 l-1 (nominal detection limit is 10 DNA copies, or about 0.06 zoospore). We did not detect DNA of Bd from sediments collected at any sites. Our filtering and amplification methods provide a new tool to investigate critical aspects of Bd in the environment. ?? Inter-Research 2007.
CTP (Cochlin-tomoprotein) detection in the profuse fluid leakage (gusher) from cochleostomy.
Ikezono, Tetsuo; Sugizaki, Kazuki; Shindo, Susumu; Sekiguchi, Satomi; Pawankar, Ruby; Baba, Shunkichi; Yagi, Toshiaki
2010-08-01
By testing 125 samples, we confirmed that Cochlin-tomoprotein (CTP) is present in the perilymph, not in cerebrospinal fluid (CSF). Perilymph and CSF exist in two distinct compartments, even in the case of a malformed inner ear with a bony defect in the lamina cribrosa, as described here. Cochleostomy might have suddenly decreased the perilymph pressure, allowing the influx of CSF into the inner ear resulting in profuse fluid leakage, first perilymph then CSF. The first purpose of this study was to further confirm the specificity of the perilymph-specific protein CTP that we reported recently. Secondly, we assessed the nature of the fluid leakage from the cochleostomy using the CTP detection test. A standardized CTP detection test was performed on 65 perilymph and 60 CSF samples. Samples of profuse fluid leakage collected from cochleostomy during cochlear implantation surgery of one patient with branchio-oto-renal (BOR) syndrome were also tested by the CTP detection test. CTP was detected in 60 of 65 perilymph samples but not in any of the CSF samples. The leaked fluid was shown to contain CTP, i.e. perilymph, at the outset, and then the CTP detection signals gradually disappeared as time elapsed.
Roman, Fabian; Iturry, Mónica; Rojas, Galeno; Barceló, Ernesto; Buschke, Herman; Allegri, Ricardo F.
2016-01-01
ABSTRACT Background: "Forgetfulness" is frequent in normal aging and characteristic of the early stages of dementia syndromes. The episodic memory test is central for detecting amnestic mild cognitive impairment (MCI). The Memory Binding Test (MBT) is a simple, easy and brief memory test to detect the early stage of episodic memory impairment. Objective: To validate the Argentine version of the MBT in a Latin American population and to estimate the diagnostic accuracy as a tool for early detection of MCI. Methods: 88 subjects (46 healthy controls and 42 patients with amnestic MCI) matched for age and educational level were evaluated by an extensive neuropsychological battery and the memory binding test. Results: A significantly better performance was detected in the control group; all MBT scales were predictive of MCI diagnosis (p<.01). The MBT showed high sensitivity (69%) and high specificity (88%), with a PPV of 93% and a NPV of 55% for associative paired recall. A statistically significant difference (c2=14,164, p<.001) was obtained when comparing the area under the curve (AUC) of the MBT (0.88) and the MMSE (0.70). Conclusion: The Argentine version of the MBT correlated significantly with the MMSE and the memory battery and is a useful tool in the detection of MCI. The operating characteristics of the MBT are well suited, surpassing other tests commonly used for detecting MCI. PMID:29213458
Delport, Johannes Andries; Mohorovic, Ivor; Burn, Sandi; McCormick, John Kenneth; Schaus, David; Lannigan, Robert; John, Michael
2016-07-01
Meticillin-resistant Staphylococcus aureus (MRSA) bloodstream infection is responsible for significant morbidity, with mortality rates as high as 60 % if not treated appropriately. We describe a rapid method to detect MRSA in blood cultures using a combined three-hour short-incubation BRUKER matrix-assisted laser desorption/ionization time-of-flight MS BioTyper protocol and a qualitative immunochromatographic assay, the Alere Culture Colony Test PBP2a detection test. We compared this combined method with a molecular method detecting the nuc and mecA genes currently performed in our laboratory. One hundred and seventeen S. aureus blood cultures were tested of which 35 were MRSA and 82 were meticillin-sensitive S. aureus (MSSA). The rapid combined test correctly identified 100 % (82/82) of the MSSA and 85.7 % (30/35) of the MRSA after 3 h. There were five false negative results where the isolates were correctly identified as S. aureus, but PBP2a was not detected by the Culture Colony Test. The combined method has a sensitivity of 87.5 %, specificity of 100 %, a positive predictive value of 100 % and a negative predictive value of 94.3 % with the prevalence of MRSA in our S. aureus blood cultures. The combined rapid method offers a significant benefit to early detection of MRSA in positive blood cultures.
Sinharay, Sandip
2017-09-01
Benefiting from item preknowledge is a major type of fraudulent behavior during educational assessments. Belov suggested the posterior shift statistic for detection of item preknowledge and showed its performance to be better on average than that of seven other statistics for detection of item preknowledge for a known set of compromised items. Sinharay suggested a statistic based on the likelihood ratio test for detection of item preknowledge; the advantage of the statistic is that its null distribution is known. Results from simulated and real data and adaptive and nonadaptive tests are used to demonstrate that the Type I error rate and power of the statistic based on the likelihood ratio test are very similar to those of the posterior shift statistic. Thus, the statistic based on the likelihood ratio test appears promising in detecting item preknowledge when the set of compromised items is known.
Gerwin, Philip M; Arbona, Rodolfo J Ricart; Riedel, Elyn R; Lepherd, Michelle L; Henderson, Ken S; Lipman, Neil S
2017-01-01
There is no consensus regarding the best practice for detecting murine pinworm infections. Initially, we evaluated 7 fecal concentration methods by using feces containing Aspiculuris tetraptera (AT) eggs (n = 20 samples per method). Sodium nitrate flotation, sodium nitrate centrifugation, Sheather sugar centrifugation, and zinc sulfate centrifugation detected eggs in 100% of samples; zinc sulfate flotation and water sedimentation detected eggs in 90%. All had better detection rates than Sheather sugar flotation (50%). To determine optimal detection methods, Swiss Webster mice were exposed to Syphacia obvelata (SO; n = 60) or AT (n = 60). We compared the following methods at days 0, 30, and 90, beginning 21 or 28 d after SO and AT exposure, respectively: fecal concentration (AT only), anal tape test (SO only), direct examination of intestinal contents (cecum and colon), Swiss roll histology (cecum and colon), and PCR analysis (pooled fur swab and feces). Detection rates for SO-exposed mice were: PCR analysis, 45%; Swiss roll histology, 30%; intestinal content exam, 27%; and tape test, 27%. The SO detection rate for PCR analysis was significantly greater than that for the tape test. Detection rates for AT-exposed mice were: intestinal content exam, 53%; PCR analysis, 33%; fecal flotation, 22%; and Swiss roll histology, 17%. The AT detection rate of PCR analysis combined with intestinal content examination was greater than for PCR analysis only and the AT detection rate of intestinal content examination was greater than for Swiss roll histology. Combining PCR analysis with intestinal content examination detected 100% of infected animals. No single test detected all positive animals. We recommend combining PCR analysis with intestinal content examination for optimal pinworm detection. PMID:28905712
Pasteran, Fernando; Tijet, Nathalie; Melano, Roberto G; Corso, Alejandra
2015-12-01
We compared carbapenemase detection among 266 Gram-negative bacilli (161 carbapenemase producers) using the Carba NP tests issued by the CLSI (CNPt-CLSI) and a novel protocol (CNPt-direct) designed for carbapenemase detection direct from bacterial cultures (instead of bacterial extracts required by the CLSI tests). The specificities were comparable (100%), but the CNPt-direct was more sensitive (98% versus 84%). The CNPt-direct was easier to perform due to the direct use of colonies and offered a more robust detection of carbapenemase producers. Copyright © 2015, American Society for Microbiology. All Rights Reserved.
Papers Based Electrochemical Biosensors: From Test Strips to Paper-Based Microfluidics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Bingwen; Du, Dan; Hua, Xin
2014-05-08
Papers based biosensors such as lateral flow test strips and paper-based microfluidic devices (or paperfluidics) are inexpensive, rapid, flexible, and easy-to-use analytical tools. An apparent trend in their detection is to interpret sensing results from qualitative assessment to quantitative determination. Electrochemical detection plays an important role in quantification. This review focuses on electrochemical (EC) detection enabled biosensors. The first part provides detailed examples in paper test strips. The second part gives an overview of paperfluidics engaging EC detections. The outlook and recommendation of future directions of EC enabled biosensors are discussed in the end.
Mohd Khari, Fatin Izzati; Karunakaran, Rina; Rosli, Roshalina; Tee Tay, Sun
2016-01-01
The objective of this study was to determine the occurrence of chromosomal and plasmid-mediated β-lactamases (AmpC) genes in a collection of Malaysian isolates of Enterobacter species. Several phenotypic tests for detection of AmpC production of Enterobacter spp. were evaluated and the agreements between tests were determined. Antimicrobial susceptibility profiles for 117 Enterobacter clinical isolates obtained from the Medical Microbiology Diagnostic Laboratory, University Malaya Medical Centre, Malaysia, from November 2012-February 2014 were determined in accordance to CLSI guidelines. AmpC genes were detected using a multiplex PCR assay targeting the MIR/ACT gene (closely related to chromosomal EBC family gene) and other plasmid-mediated genes, including DHA, MOX, CMY, ACC, and FOX. The AmpC β-lactamase production of the isolates was assessed using cefoxitin disk screening test, D69C AmpC detection set, cefoxitin-cloxacillin double disk synergy test (CC-DDS) and AmpC induction test. Among the Enterobacter isolates in this study, 39.3% were resistant to cefotaxime and ceftriaxone and 23.9% were resistant to ceftazidime. Ten (8.5%) of the isolates were resistant to cefepime, and one isolate was resistant to meropenem. Chromosomal EBC family gene was amplified from 36 (47.4%) E. cloacae and three (25%) E. asburiae. A novel blaDHA type plasmid-mediated AmpC gene was identified for the first time from an E. cloacae isolate. AmpC β-lactamase production was detected in 99 (89.2%) of 111 potential AmpC β-lactamase producers (positive in cefoxitin disk screening) using D69C AmpC detection set. The detection rates were lower with CC-DDS (80.2%) and AmpC induction tests (50.5%). There was low agreement between the D69C AmpC detection set and the other two phenotypic tests. Of the 40 isolates with AmpC genes detected in this study, 87.5%, 77.5% and 50.0% of these isolates were positive by the D69C AmpC detection set, CC-DDS and AmpC induction tests, respectively. Besides MIR/ACT gene, a novel plasmid-mediated AmpC gene belonging to the DHA-type was identified in this study. Low agreement was noted between the D69C AmpC detection set and two other phenotypic tests for detection of AmpC production in Enterobacter spp. As plasmid-mediated genes may serve as the reservoir for the emergence of antibiotic resistance in a clinical setting, surveillance and infection control measures are necessary to limit the spread of these genes in the hospital.
Mohd Khari, Fatin Izzati; Karunakaran, Rina; Rosli, Roshalina; Tee Tay, Sun
2016-01-01
Objectives The objective of this study was to determine the occurrence of chromosomal and plasmid-mediated β-lactamases (AmpC) genes in a collection of Malaysian isolates of Enterobacter species. Several phenotypic tests for detection of AmpC production of Enterobacter spp. were evaluated and the agreements between tests were determined. Methods Antimicrobial susceptibility profiles for 117 Enterobacter clinical isolates obtained from the Medical Microbiology Diagnostic Laboratory, University Malaya Medical Centre, Malaysia, from November 2012—February 2014 were determined in accordance to CLSI guidelines. AmpC genes were detected using a multiplex PCR assay targeting the MIR/ACT gene (closely related to chromosomal EBC family gene) and other plasmid-mediated genes, including DHA, MOX, CMY, ACC, and FOX. The AmpC β-lactamase production of the isolates was assessed using cefoxitin disk screening test, D69C AmpC detection set, cefoxitin-cloxacillin double disk synergy test (CC-DDS) and AmpC induction test. Results Among the Enterobacter isolates in this study, 39.3% were resistant to cefotaxime and ceftriaxone and 23.9% were resistant to ceftazidime. Ten (8.5%) of the isolates were resistant to cefepime, and one isolate was resistant to meropenem. Chromosomal EBC family gene was amplified from 36 (47.4%) E. cloacae and three (25%) E. asburiae. A novel blaDHA type plasmid-mediated AmpC gene was identified for the first time from an E. cloacae isolate. AmpC β-lactamase production was detected in 99 (89.2%) of 111 potential AmpC β-lactamase producers (positive in cefoxitin disk screening) using D69C AmpC detection set. The detection rates were lower with CC-DDS (80.2%) and AmpC induction tests (50.5%). There was low agreement between the D69C AmpC detection set and the other two phenotypic tests. Of the 40 isolates with AmpC genes detected in this study, 87.5%, 77.5% and 50.0% of these isolates were positive by the D69C AmpC detection set, CC-DDS and AmpC induction tests, respectively. Conclusions Besides MIR/ACT gene, a novel plasmid-mediated AmpC gene belonging to the DHA-type was identified in this study. Low agreement was noted between the D69C AmpC detection set and two other phenotypic tests for detection of AmpC production in Enterobacter spp. As plasmid-mediated genes may serve as the reservoir for the emergence of antibiotic resistance in a clinical setting, surveillance and infection control measures are necessary to limit the spread of these genes in the hospital. PMID:26963619
Tsoi, Kelvin K F; Chan, Joyce Y C; Hirai, Hoyee W; Wong, Adrian; Mok, Vincent C T; Lam, Linda C W; Kwok, Timothy C Y; Wong, Samuel Y S
2017-09-01
Mild cognitive impairment (MCI) is a prevalent symptom associated with the increased risk of dementia. There are many cognitive tests available for detection of MCI, and investigation of the diagnostic performance of the tests is deemed necessary. This study aims to evaluate the diagnostic performance of different cognitive tests used for MCI detection. A list of cognitive tests was identified in previous reviews and from online search engines. Literature searches were performed on each of the cognitive tests in MEDLINE, Embase, and PsycINFO from the earliest available dates of individual databases to December 31, 2016. Google Scholar was used as a supplementary search tool. Studies that were used to assess the diagnostic performance of the cognitive tests were extracted with inclusion and exclusion criteria. Each test's performance was compared with the standard diagnostic criteria. Bivariate random effects models were used to summarize the test performance as a point estimate for sensitivity and specificity, and presented in a summary receiver operating characteristic curve. Reporting quality and risk of bias were evaluated. A total of 108 studies with 23,546 participants were selected to evaluate 9 cognitive tests for MCI detection. Most of the studies used the Mini-Mental State Examination (MMSE) (n = 58) and the Montreal Cognitive Assessment (MoCA) (n = 35). The combined diagnostic performance of the MMSE in MCI detection was 0.71 sensitivity [95% confidence interval (CI): 0.66-0.75] and 0.74 specificity (95% CI: 0.70-0.78), and of the MoCA in MCI detection was 0.83 sensitivity (95% CI: 0.80-0.86) and 0.75 specificity (95% CI: 0.69-0.80). Among the 9 cognitive tests, recall tests showed the best diagnostic performance with 0.89 sensitivity (95% CI: 0.86-0.92) and 0.84 specificity (95% CI, 0.79-0.89). In subgroup analyses, long- or short-delay recall tests have shown better performance than immediate recall tests. Recall tests were shown to be the most effective test in MCI detection, especially for the population with symptoms of memory deterioration. They can be potentially used as the triage screening test for MCI in primary care setting. But when a patient shows cognitive impairments beyond memory deterioration, a more comprehensive test such as the MoCA should be used. Copyright © 2017 AMDA – The Society for Post-Acute and Long-Term Care Medicine. Published by Elsevier Inc. All rights reserved.
Sampson, Maureen L; Gounden, Verena; van Deventer, Hendrik E; Remaley, Alan T
2016-02-01
The main drawback of the periodic analysis of quality control (QC) material is that test performance is not monitored in time periods between QC analyses, potentially leading to the reporting of faulty test results. The objective of this study was to develop a patient based QC procedure for the more timely detection of test errors. Results from a Chem-14 panel measured on the Beckman LX20 analyzer were used to develop the model. Each test result was predicted from the other 13 members of the panel by multiple regression, which resulted in correlation coefficients between the predicted and measured result of >0.7 for 8 of the 14 tests. A logistic regression model, which utilized the measured test result, the predicted test result, the day of the week and time of day, was then developed for predicting test errors. The output of the logistic regression was tallied by a daily CUSUM approach and used to predict test errors, with a fixed specificity of 90%. The mean average run length (ARL) before error detection by CUSUM-Logistic Regression (CSLR) was 20 with a mean sensitivity of 97%, which was considerably shorter than the mean ARL of 53 (sensitivity 87.5%) for a simple prediction model that only used the measured result for error detection. A CUSUM-Logistic Regression analysis of patient laboratory data can be an effective approach for the rapid and sensitive detection of clinical laboratory errors. Published by Elsevier Inc.
Outlier detection in a new half-circular distribution
NASA Astrophysics Data System (ADS)
Rambli, Adzhar; Mohamed, Ibrahim Bin; Shimizu, Kunio; Khalidin, Nurliza
2015-10-01
In this paper, we use a discordancy test based on spacing theory to detect outlier in a half-circular data. Up to now, numerous discordancy tests have been proposed to detect outlier in circular distributions which are defined in [0,2π). However, some circular data lie within just half of this range. Therefore, first we introduce a new half-circular distribution developed using the inverse stereographic projection technique on a gamma distributed variable. Then, we develop a new discordancy test to detect single or multiple outliers in the half-circular data based on the spacing theory. We show the practical value of the test by applying it to an eye data set obtained from a glaucoma clinic at the University of Malaya Medical Centre, Malaysia.
NASA Astrophysics Data System (ADS)
Kehres, Jan; Lyksborg, Mark; Olsen, Ulrik L.
2017-09-01
Energy dispersive X-ray diffraction (EDXRD) can be applied for identification of liquid threats in luggage scanning in security applications. To define the instrumental design, the framework for data reduction and analysis and test the performance of the threat detection in various scenarios, a flexible laboratory EDXRD test setup was build. A data set of overall 570 EDXRD spectra has been acquired for training and testing of threat identification algorithms. The EDXRD data was acquired with limited count statistics and at multiple detector angles and merged after correction and normalization. Initial testing of the threat detection algorithms with this data set indicate the feasibility of detection levels of > 95 % true positive with < 6 % false positive alarms.
Detecting technology of biophotons
NASA Astrophysics Data System (ADS)
Ma, Junfu; Zhu, Zhaohui; Zhu, Yanbin
2002-03-01
A key technique of detecting the ultra-weak photon emission from biological system (UPE) is to change the light signal of an extremely weak level into electric signal of a considerable level when the photo-electric detecting system were be applied. This paper analyzed the difficult for detecting the ultra-weak photon emission from biological system (UPE) mainly is in the absence of high sensitivity detector in UV-visible-infra spectra region. An experimental setup for testing UPE in different spectral region was designed. Using the experimental setup the test data of different several spectral regions from 300 nm to 1060 nm has were tested. The test result show the UPE of living biological system exists in wide spectra region from UV- visible to infrared.
Sequential detection of influenza epidemics by the Kolmogorov-Smirnov test
2012-01-01
Background Influenza is a well known and common human respiratory infection, causing significant morbidity and mortality every year. Despite Influenza variability, fast and reliable outbreak detection is required for health resource planning. Clinical health records, as published by the Diagnosticat database in Catalonia, host useful data for probabilistic detection of influenza outbreaks. Methods This paper proposes a statistical method to detect influenza epidemic activity. Non-epidemic incidence rates are modeled against the exponential distribution, and the maximum likelihood estimate for the decaying factor λ is calculated. The sequential detection algorithm updates the parameter as new data becomes available. Binary epidemic detection of weekly incidence rates is assessed by Kolmogorov-Smirnov test on the absolute difference between the empirical and the cumulative density function of the estimated exponential distribution with significance level 0 ≤ α ≤ 1. Results The main advantage with respect to other approaches is the adoption of a statistically meaningful test, which provides an indicator of epidemic activity with an associated probability. The detection algorithm was initiated with parameter λ0 = 3.8617 estimated from the training sequence (corresponding to non-epidemic incidence rates of the 2008-2009 influenza season) and sequentially updated. Kolmogorov-Smirnov test detected the following weeks as epidemic for each influenza season: 50−10 (2008-2009 season), 38−50 (2009-2010 season), weeks 50−9 (2010-2011 season) and weeks 3 to 12 for the current 2011-2012 season. Conclusions Real medical data was used to assess the validity of the approach, as well as to construct a realistic statistical model of weekly influenza incidence rates in non-epidemic periods. For the tested data, the results confirmed the ability of the algorithm to detect the start and the end of epidemic periods. In general, the proposed test could be applied to other data sets to quickly detect influenza outbreaks. The sequential structure of the test makes it suitable for implementation in many platforms at a low computational cost without requiring to store large data sets. PMID:23031321
Multitarget stool DNA testing for colorectal-cancer screening.
Imperiale, Thomas F; Ransohoff, David F; Itzkowitz, Steven H; Levin, Theodore R; Lavin, Philip; Lidgard, Graham P; Ahlquist, David A; Berger, Barry M
2014-04-03
An accurate, noninvasive test could improve the effectiveness of colorectal-cancer screening. We compared a noninvasive, multitarget stool DNA test with a fecal immunochemical test (FIT) in persons at average risk for colorectal cancer. The DNA test includes quantitative molecular assays for KRAS mutations, aberrant NDRG4 and BMP3 methylation, and β-actin, plus a hemoglobin immunoassay. Results were generated with the use of a logistic-regression algorithm, with values of 183 or more considered to be positive. FIT values of more than 100 ng of hemoglobin per milliliter of buffer were considered to be positive. Tests were processed independently of colonoscopic findings. Of the 9989 participants who could be evaluated, 65 (0.7%) had colorectal cancer and 757 (7.6%) had advanced precancerous lesions (advanced adenomas or sessile serrated polyps measuring ≥1 cm in the greatest dimension) on colonoscopy. The sensitivity for detecting colorectal cancer was 92.3% with DNA testing and 73.8% with FIT (P=0.002). The sensitivity for detecting advanced precancerous lesions was 42.4% with DNA testing and 23.8% with FIT (P<0.001). The rate of detection of polyps with high-grade dysplasia was 69.2% with DNA testing and 46.2% with FIT (P=0.004); the rates of detection of serrated sessile polyps measuring 1 cm or more were 42.4% and 5.1%, respectively (P<0.001). Specificities with DNA testing and FIT were 86.6% and 94.9%, respectively, among participants with nonadvanced or negative findings (P<0.001) and 89.8% and 96.4%, respectively, among those with negative results on colonoscopy (P<0.001). The numbers of persons who would need to be screened to detect one cancer were 154 with colonoscopy, 166 with DNA testing, and 208 with FIT. In asymptomatic persons at average risk for colorectal cancer, multitarget stool DNA testing detected significantly more cancers than did FIT but had more false positive results. (Funded by Exact Sciences; ClinicalTrials.gov number, NCT01397747.).
Foddai, A C G; Grant, I R
2017-05-01
To validate an optimized peptide-mediated magnetic separation (PMS)-phage assay for detection of viable Mycobacterium avium subsp. paratuberculosis (MAP) in milk. Inclusivity, specificity and limit of detection 50% (LOD 50 ) of the optimized PMS-phage assay were assessed. Plaques were obtained for all 43 MAP strains tested. Of 12 other Mycobacterium sp. tested, only Mycobacterium bovis BCG produced small numbers of plaques. LOD 50 of the PMS-phage assay was 0·93 MAP cells per 50 ml milk, which was better than both PMS-qPCR and PMS-culture. When individual milks (n = 146) and bulk tank milk (BTM, n = 22) obtained from Johne's affected herds were tested by the PMS-phage assay, viable MAP were detected in 31 (21·2%) of 146 individual milks and 13 (59·1%) of 22 BTM, with MAP numbers detected ranging from 6-948 plaque-forming-units per 50 ml milk. PMS-qPCR and PMS-MGIT culture proved to be less sensitive tests than the PMS-phage assay. The optimized PMS-phage assay is the most sensitive and specific method available for the detection of viable MAP in milk. Further work is needed to streamline the PMS-phage assay, because the assay's multistep format currently makes it unsuitable for adoption by the dairy industry as a screening test. The inclusivity (ability to detect all MAP strains), specificity (ability to detect only MAP) and detection sensitivity (ability to detect low numbers of MAP) of the optimized PMS-phage assay have been comprehensively demonstrated for the first time. © 2017 The Society for Applied Microbiology.
A Comparison of Bias Correction Adjustments for the DETECT Procedure
ERIC Educational Resources Information Center
Nandakumar, Ratna; Yu, Feng; Zhang, Yanwei
2011-01-01
DETECT is a nonparametric methodology to identify the dimensional structure underlying test data. The associated DETECT index, "D[subscript max]," denotes the degree of multidimensionality in data. Conditional covariances (CCOV) are the building blocks of this index. In specifying population CCOVs, the latent test composite [theta][subscript TT]…
Test/QA Plan for Verification of Coliform Detection Technologies for Drinking Water
The coliform detection technologies to be tested use chromatogenic and fluorogenic growth media to detect coliforms and E. coli based on the enzymatic activity of these organisms. The systems consist of single-use sample containers that contain pre-measured reagents and can be u...
Bird, Patrick; Flannery, Jonathan; Crowley, Erin; Agin, James; Goins, David; Monteroso, Lisa; Benesh, DeAnn
2015-01-01
The 3M™ Molecular Detection Assay (MDA) Listeria is used with the 3M Molecular Detection System for the detection of Listeria species in food, food-related, and environmental samples after enrichment. The assay utilizes loop-mediated isothermal amplification to rapidly amplify Listeria target DNA with high specificity and sensitivity, combined with bioluminescence to detect the amplification. The 3M MDA Listeria method was evaluated using an unpaired study design in a multilaboratory collaborative study and compared to the AOAC Official Method of AnalysisSM (OMA) 993.12 Listeria monocytogenes in Milk and Dairy Products reference method for the detection of Listeria species in full-fat (4% milk fat) cottage cheese (25 g test portions). A total of 15 laboratories located in the continental United States and Canada participated. Each matrix had three inoculation levels: an uninoculated control level (0 CFU/test portion), and two levels artificially contaminated with Listeria monocytogenes, a low inoculum level (0.2-2 CFU/test portion) and a high inoculum level (2-5 CFU/test portion) using nonheat-stressed cells. In total, 792 unpaired replicate portions were analyzed. Statistical analysis was conducted according to the probability of detection (POD) model. Results obtained for the low inoculum level test portions produced a difference in cross-laboratory POD value of -0.07 with a 95% confidence interval of (-0.19, 0.06). No statistically significant differences were observed in the number of positive samples detected by the 3M MDA Listeria method versus the AOAC OMA method.
Ohata, Hiroshi; Oka, Masashi; Yanaoka, Kimihiko; Shimizu, Yasuhito; Mukoubayashi, Chizu; Mugitani, Kouichi; Iwane, Masataka; Nakamura, Hideya; Tamai, Hideyuki; Arii, Kenji; Nakata, Hiroya; Yoshimura, Noriko; Takeshita, Tetsuya; Miki, Kazumasa; Mohara, Osamu; Ichinose, Masao
2005-10-01
With the aim of developing more efficient gastric cancer screening programs for use in Japan, we studied a new screening program that combines serum pepsinogen (PG) testing and barium digital radiography (DR). A total of 17 647 middle-aged male subjects underwent workplace screening over a 7-year period using a combination of PG testing and DR. This program's effectiveness, as well as other characteristics of the program, was analyzed. Forty-nine cases of gastric cancer were detected (comprising 88% early cancer cases). The detection rate was 0.28%, and the positive predictive value was 0.85%. The PG test detected 63.3% of cases, DR detected 69.4% of cases, and both tests were positive in 32.7% of cancer cases. The two methods were almost equally effective, and were considerably more effective than conventional screening using photofluorography. Each screening method detected a distinct gastric cancer subgroup; the PG test efficiently detected asymptomatic small early cancer with intestinal type histology, while DR was efficient at detecting cancers with depressed or ulcerated morphology and diffuse type histology. The cost for the detection of a single cancer was much less than that for conventional screening. In fact, it is possible to further reduce the cost of detecting a single cancer to a cost comparable to that of surgically resecting a single gastric cancer. Thus, it is probable that a highly efficient gastric cancer screening system can be implemented by combining the two screening methods. Such a screening program would be beneficial in a population at high risk for gastric cancer.
NASA Astrophysics Data System (ADS)
Koshti, Ajay M.
2018-03-01
Like other NDE methods, eddy current surface crack detectability is determined using probability of detection (POD) demonstration. The POD demonstration involves eddy current testing of surface crack specimens with known crack sizes. Reliably detectable flaw size, denoted by, a90/95 is determined by statistical analysis of POD test data. The surface crack specimens shall be made from a similar material with electrical conductivity close to the part conductivity. A calibration standard with electro-discharged machined (EDM) notches is typically used in eddy current testing for surface crack detection. The calibration standard conductivity shall be within +/- 15% of the part conductivity. This condition is also applicable to the POD demonstration crack set. Here, a case is considered, where conductivity of the crack specimens available for POD testing differs by more than 15% from that of the part to be inspected. Therefore, a direct POD demonstration of reliably detectable flaw size is not applicable. Additional testing is necessary to use the demonstrated POD test data. An approach to estimate the reliably detectable flaw size in eddy current testing for part made from material A using POD crack specimens made from material B with different conductivity is provided. The approach uses additional test data obtained on EDM notch specimens made from materials A and B. EDM notch test data from the two materials is used to create a transfer function between the demonstrated a90/95 size on crack specimens made of material B and the estimated a90/95 size for part made of material A. Two methods are given. For method A, a90/95 crack size for material B is given and POD data is available. Objective of method A is to determine a90/95 crack size for material A using the same relative decision threshold that was used for material B. For method B, target crack size a90/95 for material A is known. Objective is to determine decision threshold for inspecting material A.
Goel, Amit; Shivaprasad, Channabasappa; Kolly, Anish; Sarathi H A, Vijaya; Atluri, Sridevi
2017-01-01
The early diagnosis of diabetic peripheral neuropathy (DPN) is challenging. Sudomotor dysfunction is one of the earliest detectable abnormalities in DPN. The present study aimed to determine the diagnostic performance of the electrochemical skin conductance (ESC) test in detecting early DPN, compared with the vibration perception threshold (VPT) test and diabetic neuropathy symptom (DNS) score, using the modified neuropathy disability score (NDS) as the reference standard. Five hundred and twenty-three patients with type 2 diabetes underwent an NDS-based clinical assessment for neuropathy. Participants were classified into the DPN and non-DPN groups based on the NDS (≥ 6). Both groups were evaluated further using the DNS, and VPT and ESC testing. A receiver-operator characteristic (ROC) curve analysis was performed to compare the efficacy of ESC measurements with those of DNS and VPT testing in detecting DPN. The DPN group (n = 110, 21%) had significantly higher HbA1c levels and longer diabetes durations compared with the non-DPN group (n = 413). The sensitivity of feet ESC < 60 μS, VPT testing, and DNS in detecting DPN were 85%, 72%, and 52%, respectively. The specificity of feet ESC, VPT, and DNS in detecting DPN were 85%, 90% and 60% respectively. The areas under the curves of the ROC plots for feet ESC, VPT testing, and DNS were 0.88, 0.84, and 0.6, respectively. A significant inverse linear relationship was noted between VPT and feet ESC (r = -0.45, p = <0.0001). The odds ratios for having DPN, based on the mean feet ESC testing < 60 μS, VPT testing > 15 V, and DNS ≥ 1, were 16.4, 10.9 and 1.8, respectively. ESC measurement is an objective and sensitive technique for the early detection of DPN. Feet ESC measurement was superior to VPT testing for identifying patients with early DPN.
Kolly, Anish; Sarathi H. A., Vijaya; Atluri, Sridevi
2017-01-01
The early diagnosis of diabetic peripheral neuropathy (DPN) is challenging. Sudomotor dysfunction is one of the earliest detectable abnormalities in DPN. The present study aimed to determine the diagnostic performance of the electrochemical skin conductance (ESC) test in detecting early DPN, compared with the vibration perception threshold (VPT) test and diabetic neuropathy symptom (DNS) score, using the modified neuropathy disability score (NDS) as the reference standard. Five hundred and twenty-three patients with type 2 diabetes underwent an NDS-based clinical assessment for neuropathy. Participants were classified into the DPN and non-DPN groups based on the NDS (≥ 6). Both groups were evaluated further using the DNS, and VPT and ESC testing. A receiver-operator characteristic (ROC) curve analysis was performed to compare the efficacy of ESC measurements with those of DNS and VPT testing in detecting DPN. The DPN group (n = 110, 21%) had significantly higher HbA1c levels and longer diabetes durations compared with the non-DPN group (n = 413). The sensitivity of feet ESC < 60 μS, VPT testing, and DNS in detecting DPN were 85%, 72%, and 52%, respectively. The specificity of feet ESC, VPT, and DNS in detecting DPN were 85%, 90% and 60% respectively. The areas under the curves of the ROC plots for feet ESC, VPT testing, and DNS were 0.88, 0.84, and 0.6, respectively. A significant inverse linear relationship was noted between VPT and feet ESC (r = -0.45, p = <0.0001). The odds ratios for having DPN, based on the mean feet ESC testing < 60 μS, VPT testing > 15 V, and DNS ≥ 1, were 16.4, 10.9 and 1.8, respectively. ESC measurement is an objective and sensitive technique for the early detection of DPN. Feet ESC measurement was superior to VPT testing for identifying patients with early DPN. PMID:28880907
Balagon, Marivic F.; Maghanoy, Armi; Orcullo, Florenda M.; Cang, Marjorie; Dias, Ronaldo Ferreira; Collovati, Marco; Reed, Steven G.
2014-01-01
Leprosy remains an important health problem in a number of regions. Early detection of infection, followed by effective treatment, is critical to reduce disease progression. New sensitive and specific tools for early detection of infection will be a critical component of an effective leprosy elimination campaign. Diagnosis is made by recognizing clinical signs and symptoms, but few clinicians are able to confidently identify these. Simple tests to facilitate referral to leprosy experts are not widely available, and the correct diagnosis of leprosy is often delayed. In this report, we evaluate the performance of a new leprosy serological test (NDO-LID). As expected, the test readily detected clinically confirmed samples from patients with multibacillary (MB) leprosy, and the rate of positive results declined with bacterial burden. NDO-LID detected larger proportions of MB and paucibacillary (PB) leprosy than the alternative, the Standard Diagnostics leprosy test (87.0% versus 81.7% and 32.3% versus 6.5%, respectively), while also demonstrating improved specificity (97.4% versus 90.4%). Coupled with a new cell phone-based test reader platform (Smart Reader), the NDO-LID test provided consistent, objective test interpretation that could facilitate wider use in nonspecialized settings. In addition, results obtained from sera at the time of diagnosis, versus at the end of treatment, indicated that the quantifiable nature of this system can also be used to monitor treatment efficacy. Taken together, these data indicate that the NDO-LID/Smart Reader system can assist in the diagnosis and monitoring of MB leprosy and can detect a significant number of earlier-stage infections. PMID:24478496
A modified Elek test for detection of toxigenic corynebacteria in the diagnostic laboratory.
Engler, K H; Glushkevich, T; Mazurova, I K; George, R C; Efstratiou, A
1997-02-01
The detection of toxigenicity among Corynebacterium diphtheriae and Corynebacterium ulcerans strains is the most important test for the microbiological diagnosis of diphtheria. Difficulties with current methods, in particular the Elek test, are well documented. We therefore describe a modified Elek test which provides an accurate result after only 16 h of incubation, in contrast to 48 h for the conventional test.
Using electrolyte leakage tests to determine lifting windows and detect tissue damage
Richard W. Tinus
2002-01-01
Physiological testing is rapidly coming into use as a means to determine the condition of nursery stock and predict how it will respond to treatment or use. One such test, the electrolyte leakage test, can be used to measure cold hardiness and detect tissue damage. The principle of this test is that when cell membranes are damaged, electrolytes leak out into the water...
Eddy-Current Detection of Weak Bolt Heads
NASA Technical Reports Server (NTRS)
Messina, C. P.
1987-01-01
Electronic test identifies flawed units passing hardness tests. Eddy-current test detects weakness in head-to-shank junctions of 1/4-28 cup-washer lock bolts. Developed for alloy A286 steel bolts in Space Shuttle main engine fuel turbo-pump. Test examines full volume of head, including head-to-shank transition and nondestructively screens out potentially defective units. Test adapts to any other alloys.
NASA Astrophysics Data System (ADS)
Menne, Matthew J.; Williams, Claude N., Jr.
2005-10-01
An evaluation of three hypothesis test statistics that are commonly used in the detection of undocumented changepoints is described. The goal of the evaluation was to determine whether the use of multiple tests could improve undocumented, artificial changepoint detection skill in climate series. The use of successive hypothesis testing is compared to optimal approaches, both of which are designed for situations in which multiple undocumented changepoints may be present. In addition, the importance of the form of the composite climate reference series is evaluated, particularly with regard to the impact of undocumented changepoints in the various component series that are used to calculate the composite.In a comparison of single test changepoint detection skill, the composite reference series formulation is shown to be less important than the choice of the hypothesis test statistic, provided that the composite is calculated from the serially complete and homogeneous component series. However, each of the evaluated composite series is not equally susceptible to the presence of changepoints in its components, which may be erroneously attributed to the target series. Moreover, a reference formulation that is based on the averaging of the first-difference component series is susceptible to random walks when the composition of the component series changes through time (e.g., values are missing), and its use is, therefore, not recommended. When more than one test is required to reject the null hypothesis of no changepoint, the number of detected changepoints is reduced proportionately less than the number of false alarms in a wide variety of Monte Carlo simulations. Consequently, a consensus of hypothesis tests appears to improve undocumented changepoint detection skill, especially when reference series homogeneity is violated. A consensus of successive hypothesis tests using a semihierarchic splitting algorithm also compares favorably to optimal solutions, even when changepoints are not hierarchic.
Werner, Simone; Krause, Friedemann; Rolny, Vinzent; Strobl, Matthias; Morgenstern, David; Datz, Christian; Chen, Hongda; Brenner, Hermann
2016-04-01
In initial studies that included colorectal cancer patients undergoing diagnostic colonoscopy, we had identified a serum marker combination able to detect colorectal cancer with similar diagnostic performance as fecal immunochemical test (FIT). In this study, we aimed to validate the results in participants of a large colorectal cancer screening study conducted in the average-risk, asymptomatic screening population. We tested serum samples from 1,200 controls, 420 advanced adenoma patients, 4 carcinoma in situ patients, and 36 colorectal cancer patients with a 5-marker blood test [carcinoembryonic antigen (CEA)+anti-p53+osteopontin+seprase+ferritin]. The diagnostic performance of individual markers and marker combinations was assessed and compared with stool test results. AUCs for the detection of colorectal cancer and advanced adenomas with the 5-marker blood test were 0.78 [95% confidence interval (CI), 0.68-0.87] and 0.56 (95% CI, 0.53-0.59), respectively, which now is comparable with guaiac-based fecal occult blood test (gFOBT) but inferior to FIT. With cutoffs yielding specificities of 80%, 90%, and 95%, the sensitivities for the detection of colorectal cancer were 64%, 50%, and 42%, and early-stage cancers were detected as well as late-stage cancers. For osteopontin, seprase, and ferritin, the diagnostic performance in the screening setting was reduced compared with previous studies in diagnostic settings while CEA and anti-p53 showed similar diagnostic performance in both settings. Performance of the 5-marker blood test under screening conditions is inferior to FIT even though it is still comparable with the performance of gFOBT. CEA and anti-p53 could contribute to the development of a multiple marker blood-based test for early detection of colorectal cancer. ©2015 American Association for Cancer Research.
Bartholomew, Rachel A.; Ozanich, Richard M.; Arce, Jennifer S.; Engelmann, Heather E.; Heredia-Langner, Alejandro; Hofstad, Beth A.; Hutchison, Janine R.; Jarman, Kristin; Melville, Angela M.; Victry, Kristin D.
2017-01-01
There is little published data on the performance of biological indicator tests and immunoassays that could be used by first responders to determine if a suspicious powder contains a potential biothreat agent. We evaluated a range of biological indicator tests, including 3 protein tests, 2 ATP tests, 1 DNA test, and 1 FTIR spectroscopy instrument for their ability to screen suspicious powders for Bacillus anthracis (B. anthracis) spores and ricin. We also evaluated 12 immunoassays (mostly lateral flow immunoassays) for their ability to screen for B. anthracis and ricin. We used a cost-effective, statistically based test plan that allows instruments to be evaluated at performance levels ranging from 0.85 to 0.95 lower confidence bound of the probability of detection at confidence levels of 80% to 95%. We also assessed interference with 22 common suspicious powders encountered in the field. The detection reproducibility for the biological indicators was evaluated at 108 B. anthracis spores and 62.5 μg ricin, and the immunoassay detection reproducibility was evaluated at 107 spores/mL (B. anthracis) and 0.1 μg/mL (ricin). Seven out of 12 immunoassays met our most stringent criteria for B. anthracis detection, while 9 out of 12 met our most stringent test criteria for ricin detection. Most of the immunoassays also detected ricin in 3 different crude castor seed preparations. Our testing results varied across products and sample preparations, indicating the importance of reviewing performance data for specific instruments and sample types of interest for the application in order to make informed decisions regarding the selection of biodetection equipment for field use. PMID:28192054
Bartholomew, Rachel A; Ozanich, Richard M; Arce, Jennifer S; Engelmann, Heather E; Heredia-Langner, Alejandro; Hofstad, Beth A; Hutchison, Janine R; Jarman, Kristin; Melville, Angela M; Victry, Kristin D; Bruckner-Lea, Cynthia J
There is little published data on the performance of biological indicator tests and immunoassays that could be used by first responders to determine if a suspicious powder contains a potential biothreat agent. We evaluated a range of biological indicator tests, including 3 protein tests, 2 ATP tests, 1 DNA test, and 1 FTIR spectroscopy instrument for their ability to screen suspicious powders for Bacillus anthracis (B. anthracis) spores and ricin. We also evaluated 12 immunoassays (mostly lateral flow immunoassays) for their ability to screen for B. anthracis and ricin. We used a cost-effective, statistically based test plan that allows instruments to be evaluated at performance levels ranging from 0.85 to 0.95 lower confidence bound of the probability of detection at confidence levels of 80% to 95%. We also assessed interference with 22 common suspicious powders encountered in the field. The detection reproducibility for the biological indicators was evaluated at 10 8 B. anthracis spores and 62.5 μg ricin, and the immunoassay detection reproducibility was evaluated at 10 7 spores/mL (B. anthracis) and 0.1 μg/mL (ricin). Seven out of 12 immunoassays met our most stringent criteria for B. anthracis detection, while 9 out of 12 met our most stringent test criteria for ricin detection. Most of the immunoassays also detected ricin in 3 different crude castor seed preparations. Our testing results varied across products and sample preparations, indicating the importance of reviewing performance data for specific instruments and sample types of interest for the application in order to make informed decisions regarding the selection of biodetection equipment for field use.
Relative Performance of HPV and Cytology Components of Cotesting in Cervical Screening.
Schiffman, Mark; Kinney, Walter K; Cheung, Li C; Gage, Julia C; Fetterman, Barbara; Poitras, Nancy E; Lorey, Thomas S; Wentzensen, Nicolas; Befano, Brian; Schussler, John; Katki, Hormuzd A; Castle, Philip E
2018-05-01
The main goal of cervical screening programs is to detect and treat precancer before cancer develops. Human papillomavirus (HPV) testing is more sensitive than cytology for detecting precancer. However, reports of rare HPV-negative, cytology-positive cancers are motivating continued use of both tests (cotesting) despite increased testing costs. We quantified the detection of cervical precancer and cancer by cotesting compared with HPV testing alone at Kaiser Permanente Northern California (KPNC), where 1 208 710 women age 30 years and older have undergone triennial cervical cotesting since 2003. Screening histories preceding cervical cancers (n = 623) and precancers (n = 5369) were examined to assess the relative contribution of the cytology and HPV test components in identifying cases. The performances of HPV testing and cytology were compared using contingency table methods, general estimating equation models, and nonparametric statistics; all statistical tests were two-sided. HPV testing identified more women subsequently diagnosed with cancer (P < .001) and precancer (P < .001) than cytology. HPV testing was statistically significantly more likely to be positive for cancer at any time point (P < .001), except within 12 months (P = .10). HPV-negative/cytology-positive results preceded only small fractions of cases of precancer (3.5%) and cancer (5.9%); these cancers were more likely to be regional or distant stage with squamous histopathology than other cases. Given the rarity of cancers among screened women, the contribution of cytology to screening translated to earlier detection of at most five cases per million women per year. Two-thirds (67.9%) of women found to have cancer during 10 years of follow-up at KPNC were detected by the first cotest performed. The added sensitivity of cotesting vs HPV alone for detection of treatable cancer affected extremely few women.
Portillo Villares, Isabel; Arana-Arri, Eunate; Idigoras Rubio, Isabel; Espinás Piñol, Josep Alfons; Pérez Riquelme, Francisco; de la Vega Prieto, Mariola; González Aledo, Alvaro; Oceja Setien, Elena; Vanaclocha Espi, Mercedes; Ibáñez Cabanell, Josefa; Salas Trejo, Dolores
2017-02-20
In this study, the results of six Colorectal Cancer Screening Population Programmes are shown (Catalonia, Valence, Murcia, Cantabria, the Basque Country and the Canary Islands collected between 2005 and 2012. These programmes use the faeces occult blood test (FOBt) biennial. Objective: To determine and compare the results of lesions detected by the programmes, participation, sex, age and test used. Retrospective cohort study based on people invited, aged between 50-74 years, in at least a complete round. Lesions considered: Advanced Adenomas (AA), Colorectal Invasive Cancer (CRC) and both of them, known as Advanced Neoplasia (AN). Logistic Regression and time trends are used. 1,995,719 of invitations registered, with an average participation-rate of 46.7%. 21,228 Advanced Neoplasias (2,813 CRC and 18,415 AA). Differences in detection rates observed between programmes (varying from 15.1‰ to 35.8‰ between participants). Participation rates were related to lesions' detection rates (OR 1.25 in 40-60% of participation). . Inmunochemical qualitative test showed an OR of 4.79 and quantitative test an OR of 7.30 over the guaiac test. Men showed an OR of 2.73 with respect to women. In 2012 the Advanced Neoplasia rate for women and men was 33.1 and 14.2 by 1,000 participants. The test used was the most important factor for detecting lesions. Time trends showed an increase in detected lesions caused by the change of the type of test in 2010.
Chirathaworn, Chintana; Janwitthayanan, Weena; Sereemaspun, Amornpun; Lertpocasombat, Kanchalee; Rungpanich, Utane; Ekpo, Pattama; Suwancharoen, Duangjai
2014-04-01
Detection of antibody specific to Leptospira by various immunological techniques has been used for leptospirosis diagnosis. However, the sensitivity of antibody detection during the first few days after infection is low. Molecular techniques are suggested to provide earlier diagnosis than antibody detection, but a rapid and easy to perform assay for Leptospira antigen detection would provide an additional useful tool for disease diagnosis. In this study, we coupled gold nanoparticles with antibody to LipL32, a protein commonly found in pathogenic Leptospira. This coupled gold reagent was used in the immunochromatographic strip for Leptospira detection. We demonstrated that the sensitivity of Leptospira detection by this strip was 10(3) ml(-1). There was no positive result detected when strips were tested with non-pathogenic Leptospira, Staphylococcus aureus, Streptococcus group B, Acinetobacter baumannii, Escherichia coli, Salmonella typhi, Klebsiella pneumoniae, Enterococcus faecalis or Enterococcus faecium. These data suggest that gold nanoparticles coupled with antibody to LipL32 could be used for Leptospira detection by a rapid test based on an immunochromatographic technique.
Measuring indigenous photosynthetic organisms to detect chemical warefare agents in water
Greenbaum, Elias; Sanders, Charlene A.
2005-11-15
A method of testing water to detect the presence of a chemical or biological warfare agent is disclosed. The method is carried out by establishing control data by providing control water containing indigenous organisms but substantially free of a chemical and a biological warfare agent. Then measuring photosynthetic activity of the control water with a fluorometer to obtain control data to compare with test data to detect the presence of the chemical or agent. The test data is gathered by providing test water comprising the same indigenous organisms as contained in the control water. Further, the test water is suspected of containing the chemical or agent to be tested for. Photosynthetic activity is also measured by fluorescence induction in the test water using a fluorometer.
Salter, Robert; Holmes, Steven; Legg, David; Coble, Joel; George, Bruce
2012-02-01
Pork tissue samples that tested positive and negative by the Charm II tetracycline test screening method in the slaughter plant laboratory were tested with the modified AOAC International liquid chromatography tandem mass spectrometry (LC-MS-MS) method 995.09 to determine the predictive value of the screening method at detecting total tetracyclines at 10 μg/kg of tissue, in compliance with Russian import regulations. There were 218 presumptive-positive tetracycline samples of 4,195 randomly tested hogs. Of these screening test positive samples, 83% (182) were positive, >10 μg/kg by LC-MS-MS; 12.8% (28) were false violative, greater than limit of detection (LOD) but <10 μg/kg; and 4.2% (8) were not detected at the LC-MS-MS LOD. The 36 false-violative and not-detected samples represent 1% of the total samples screened. Twenty-seven of 30 randomly selected tetracycline screening negative samples tested below the LC-MS-MS LOD, and 3 samples tested <3 μg/kg chlortetracycline. Results indicate that the Charm II tetracycline test is effective at predicting hogs containing >10 μg/kg total tetracyclines in compliance with Russian import regulations.
Tamaro, Giorgio; Donato, Michela; Princi, Tanja; Parco, Sergio
2009-04-01
A symptom-based diagnosis of infectious mononucleosis is not sufficiently accurate, since some clinical symptoms of infectious mononucleosis are also detected in other virally induced diseases. Moreover, not all patients suffering from infectious mononucleosis show circulating atypical lymphocytes, which are considered characteristic of this disease. Therefore, when this disorder is suspected, serum analyses are carried out to detect the presence of certain immunoglobulins associated with infectious mononucleosis in the patient's blood. The aim of this study was to evaluate the sensitivity and the specificity of a rapid test detecting heterophil antibodies in diagnosing infectious mononucleosis in a paediatric population. We considered 163 paediatric patients with suspected infectious mononucleosis and we tested their serums to detect heterophil antibodies (using an inexpensive and rapid test) and specific immunoglobulins directed against Epstein-Barr virus (EBV) (these assays are known to be characterized by high sensitivity and specificity, but are more expensive and time-consuming). By comparing the results of the rapid test with those of the other assays, we found that the sensitivity of the first test was 61.8%, whereas its specificity was sufficiently high (about 90%). We show that, in paediatric patients, the detection of heterophil antibodies is not a very sensitive test, therefore the determination of immunoglobulins against specific antigens of EBV is recommended.
Paper Test Cards for Presumptive Testing of Very Low Quality Antimalarial Medications
Weaver, Abigail A.; Lieberman, Marya
2015-01-01
Carrying out chemical analysis of antimalarials to detect low-quality medications before they reach a patient is a costly venture. Here, we show that a library of chemical color tests embedded on a paper card can presumptively identify formulations corresponding to very low quality antimalarial drugs. The presence or absence of chloroquine (CQ), doxycycline (DOX), quinine, sulfadoxine, pyrimethamine, and primaquine antimalarial medications, in addition to fillers used in low-quality pharmaceuticals, are indicated by patterns of colors that are generated on the test cards. Test card sensitivity for detection of these pure components ranges from 90% to 100% with no false positives in the absence of pharmaceutical. The color intensities from reactions characteristic of CQ or DOX allowed visual detection of formulations of these medications cut with 60% or 100% filler, although samples cut with 30% filler could not be reliably detected colorimetrically. However, the addition of unexpected fillers, even in 30% quantities, or substitute pharmaceuticals, could sometimes be detected by other color reactions on the test cards. Tests are simple and inexpensive enough to be carried out in clinics, pharmacies, and ports of entry and could provide a screening method to presumptively indicate very low quality medicines throughout the supply chain. PMID:25897064
Rapid, whole blood diagnostic test for detecting anti-hantavirus antibody in rats.
Amada, Takako; Yoshimatsu, Kumiko; Yasuda, Shumpei P; Shimizu, Kenta; Koma, Takaaki; Hayashimoto, Nobuhito; Gamage, Chandika D; Nishio, Sanae; Takakura, Akira; Arikawa, Jiro
2013-10-01
Hantavirus is a causative agent of rodent-borne viral zoonoses, hemorrhagic fever with renal syndrome (HFRS) and hantavirus pulmonary syndrome. Seoul virus (SEOV) is a causative agent of urban and laboratory rat-associated HFRS worldwide. Surveillance of rodents has been done mainly by serological detection of hantavirus-specific antibodies by enzyme linked immunosorbent assay (ELISA) and immunofluorescent antibody assay (IFA). An immunochromatographic (ICG) test was developed with the N-terminal 103 amino acids of nucleocapsid protein of Hantaan virus expressed by Escherichia coli as an antigen to detect IgG antibody specific to hantavirus in sera from Rattus sp. animals. Antibody-detecting sensitivity of the ICG test was the same as that of ELISA and about 100-times higher than that of IFA. Overall sensitivities and specificities of the ICG test in comparison to ELISA and IFA for sera from 192 urban rats and 123 laboratory rats were 99.3% and 100%, respectively. Diluted whole blood samples without separation could be used for the ICG test. The ICG test enabled detection of antibodies to SEOV, Hantaan, Dobrava/Belgrade, and Thailand viruses, which are causative agents of HFRS throughout Eurasia. The ICG test is a rapid, simple and safe method for diagnosis of SEOV infection in rats. Copyright © 2013 Elsevier B.V. All rights reserved.
Study on the Automatic Detection Method and System of Multifunctional Hydrocephalus Shunt
NASA Astrophysics Data System (ADS)
Sun, Xuan; Wang, Guangzhen; Dong, Quancheng; Li, Yuzhong
2017-07-01
Aiming to the difficulty of micro pressure detection and the difficulty of micro flow control in the testing process of hydrocephalus shunt, the principle of the shunt performance detection was analyzed.In this study, the author analyzed the principle of several items of shunt performance detection,and used advanced micro pressure sensor and micro flow peristaltic pump to overcome the micro pressure detection and micro flow control technology.At the same time,This study also puted many common experimental projects integrated, and successfully developed the automatic detection system for a shunt performance detection function, to achieve a test with high precision, high efficiency and automation.
Application of immunoassay for detection of Helicobacter pylori antigens in the dental plaque.
Leszczyńska, K; Namiot, D B; Namiot, Z; Leszczyńska, J K; Jakoniuk, P; Kemona, A
2009-01-01
The aim of this study was to determine the viability of the commercial test currently used for detection of H. pylori antigens in the stool for detection of H. pylori antigens in dental plaque. A total of 164 dyspeptic patients entered the study; 95 H. pylori infected (positive result of at least 4 of 5 diagnostic tests: Campylobacter-like organisms test (CLO test), histology, culture, stool antigens, serology) and 69 noninfected (negative results of 4 diagnostic tests: CLO test, histology, culture, stool antigens). Dental plaque was collected from natural teeth of the patients and incubated in microaerophilic conditions for 72 hours before immunoassay. Experimental findings included that optimal dental plaque weight to perform the examination was over 2 mg and that preliminary incubation increased significantly the number of positive results (p<0.002). It was also found that H. pylori antigens in the dental plaque were positive in 81.2% of infected and only 17.7% of non-infected subjects (p<0.001), while the reproducibility of results was 95%. The immunoassay for detection of H. pylori antigens in the stool may be used, after minor adaptations (specifically pre-incubation in microaerophilic conditions) for H. pylori antigen detection in dental plaque.
Development of a database and processing method for detecting hematotoxicity adverse drug events.
Shimai, Yoshie; Takeda, Toshihiro; Manabe, Shirou; Teramoto, Kei; Mihara, Naoki; Matsumura, Yasushi
2015-01-01
Adverse events are detected by monitoring the patient's status, including blood test results. However, it is difficult to identify all adverse events based on recognition by individual doctors. We developed a system that can be used to detect hematotoxicity adverse events according to blood test results recorded in an electronic medical record system. The blood test results were graded based on Common Terminology Criteria for Adverse Events (CTCAE) and changes in the blood test results (Up, Down, Flat) were assessed according to the variation in the grade. The changes in the blood test and injection data were stored in a database. By comparing the date of injection and start and end dates of the change in the blood test results, adverse events related to a designated drug were detected. Using this method, we searched for the occurrence of serious adverse events (CTCAE Grades 3 or 4) concerning WBC, ALT and creatinine related to paclitaxel at Osaka University Hospital. The rate of occurrence of a decreased WBC count, increased ALT level and increased creatinine level was 36.0%, 0.6% and 0.4%, respectively. This method is useful for detecting and estimating the rate of occurrence of hematotoxicity adverse drug events.
Kim, Young Ah; Lee, Eun-Hye; Kim, Kwang-Ok; Lee, Yong Tae; Hammock, Bruce D.; Lee, Hye-Sung
2014-01-01
An immunochromatographic assay (ICA) based on competitive antigen-coated format using colloidal gold as the label was developed for the detection of the organophosphorus insecticide chlorpyrifos. The ICA test strip consisted of a membrane with a detection zone, a sample pad and an absorbent pad. The membrane was separately coated with chlorpyrifos hapten-OVA conjugate (test line) and anti-mouse IgG (control line). Based on the fact that the competition is between the migrating analyte in the sample and the analyte hapten immobilized on the test strip for the binding sites of the antibody-colloidal gold (Ab-CG) conjugate migrating on the test strip, this study suggests that the relative migration speed between the two migrating substances is a critically important factor for the sensitive detection by competitive ICA. This criterion was utilized for the confirmation of appropriateness of a nitrocellulose (NC) membrane for chlorpyrifos ICA. The detection limit of the ICA for chlorpyrifos standard and chlorpyrifos spiked into agricultural samples were 10 and 50 ng mL−1, respectively. The assay time for the ICA test was less than 10 min, suitable for rapid on-site testing of chlorpyrifos. PMID:21504817
Financial comparison of three testing strategies for detection of estrus in dairy cattle.
Mohammed, H O; Loefler, S; Shearer, J
1990-03-15
Three commercial tests that measure progesterone content in milk were evaluated for accuracy of estrus detection. The tests were evaluated on 96 milk samples collected from Holstein cows at a commercial dairy farm in central Florida. The test results were compared with the results of radioimmunoassay on the same sample. Comparisons were made by calculating the sensitivities, specificities, and predictive values. The significance of the statistical association between the tests and the radioimmunoassay was evaluated by use of the McNemar chi 2 test. Decision-tree analysis was used to determine the most useful testing strategy, considering both cost and accuracy. The cowside progesterone assay on estrus-mount detector-positive cows was more profitable than use of estrus-mount patches alone. The return on investment was higher with the cowside test, making it preferred as a field test for detecting estrus.
Schwarzkopf, Dietrich S.; Bahrami, Bahador; Fleming, Stephen M.; Jackson, Ben M.; Goch, Tristam J. C.; Saygin, Ayse P.; Miller, Luke E.; Pappa, Katerina; Pavisic, Ivanna; Schade, Rachel N.; Noyce, Alastair J.; Crutch, Sebastian J.; O'Keeffe, Aidan G.; Schrag, Anette E.; Morris, Huw R.
2018-01-01
ABSTRACT Background: People with Parkinson's disease (PD) who develop visuo‐perceptual deficits are at higher risk of dementia, but we lack tests that detect subtle visuo‐perceptual deficits and can be performed by untrained personnel. Hallucinations are associated with cognitive impairment and typically involve perception of complex objects. Changes in object perception may therefore be a sensitive marker of visuo‐perceptual deficits in PD. Objective: We developed an online platform to test visuo‐perceptual function. We hypothesised that (1) visuo‐perceptual deficits in PD could be detected using online tests, (2) object perception would be preferentially affected, and (3) these deficits would be caused by changes in perception rather than response bias. Methods: We assessed 91 people with PD and 275 controls. Performance was compared using classical frequentist statistics. We then fitted a hierarchical Bayesian signal detection theory model to a subset of tasks. Results: People with PD were worse than controls at object recognition, showing no deficits in other visuo‐perceptual tests. Specifically, they were worse at identifying skewed images (P < .0001); at detecting hidden objects (P = .0039); at identifying objects in peripheral vision (P < .0001); and at detecting biological motion (P = .0065). In contrast, people with PD were not worse at mental rotation or subjective size perception. Using signal detection modelling, we found this effect was driven by change in perceptual sensitivity rather than response bias. Conclusions: Online tests can detect visuo‐perceptual deficits in people with PD, with object recognition particularly affected. Ultimately, visuo‐perceptual tests may be developed to identify at‐risk patients for clinical trials to slow PD dementia. © 2018 The Authors. Movement Disorders published by Wiley Periodicals, Inc. on behalf of International Parkinson and Movement Disorder Society. PMID:29473691
NASA Astrophysics Data System (ADS)
Ghosh Dastider, Shibajyoti; Barizuddin, Syed; Dweik, Majed; Almasri, Mahmoud F.
2012-05-01
An impedance biosensor was designed, fabricated and tested for detection of viable Escherichia coli O157:H7 in food samples. This device consists of interdigitated microelectrode array (IDEA) fabricated using thin layer of sputtered gold, embedded under a polydimethylsiloxane (PDMS) microchannel. The array of electrodes is designed to detect viable EColi in different food products. The active surface area of the detection array was modified using goat anti-E.coli polyclonal IgG antibody. Contaminated food samples were tested by infusing the supernatant containing bacteria over the IDEA's, through the microchannel. Antibody-antigen binding on the electrodes results in impedance change. Four serial concentrations of E.coli contaminated food samples (3x102 CFUmL-1 to 3x105 CFUmL-1) were tested. The biosensor successfully detected the E.coli samples, with the lower detection limit being 3x103 CFUmL-1 (up to 3cells/μl). Comparing the test results with an IDEA impedance biosensor without microchannel (published elsewhere) indicates that this biosensor have two order of magnitude times higher sensitivity. The proposed biosensor provides qualitative and quantitative detection, and potentially could be used for detection of other type of bacteria by immobilizing the specific type of antibody.
Cascaded image analysis for dynamic crack detection in material testing
NASA Astrophysics Data System (ADS)
Hampel, U.; Maas, H.-G.
Concrete probes in civil engineering material testing often show fissures or hairline-cracks. These cracks develop dynamically. Starting at a width of a few microns, they usually cannot be detected visually or in an image of a camera imaging the whole probe. Conventional image analysis techniques will detect fissures only if they show a width in the order of one pixel. To be able to detect and measure fissures with a width of a fraction of a pixel at an early stage of their development, a cascaded image analysis approach has been developed, implemented and tested. The basic idea of the approach is to detect discontinuities in dense surface deformation vector fields. These deformation vector fields between consecutive stereo image pairs, which are generated by cross correlation or least squares matching, show a precision in the order of 1/50 pixel. Hairline-cracks can be detected and measured by applying edge detection techniques such as a Sobel operator to the results of the image matching process. Cracks will show up as linear discontinuities in the deformation vector field and can be vectorized by edge chaining. In practical tests of the method, cracks with a width of 1/20 pixel could be detected, and their width could be determined at a precision of 1/50 pixel.
PCR Testing of IVC Filter Tops as a Method for Detecting Murine Pinworms and Fur Mites.
Gerwin, Philip M; Ricart Arbona, Rodolfo J; Riedel, Elyn R; Henderson, Kenneth S; Lipman, Neil S
2017-11-01
We evaluated PCR testing of filter tops from cages maintained on an IVC system through which exhaust air is filtered at the cage level as a method for detecting parasite-infected and -infested cages. Cages containing 4 naïve Swiss Webster mice received 360 mL of uncontaminated aspen chip or α-cellulose bedding (n = 18 cages each) and 60 mL of the same type of bedding weekly from each of the following 4 groups of cages housing mice infected or infested with Syphacia obvelata (SO), Aspiculuris tetraptera (AT), Myocoptes musculinus (MC), or Myobia musculi (MB) and Radfordia affinis (RA; 240 mL bedding total). Detection rates were compared at 30, 60, and 90 d after initiating bedding exposure, by using PCR analysis of filter tops (media extract and swabs) and testing of mouse samples (fur swab [direct] PCR testing, fecal flotation, anal tape test, direct examination of intestinal contents, and skin scrape). PCR testing of filter media extract detected 100% of all parasites at 30 d (both bedding types) except for AT (α-cellulose bedding, 67% detection rate); identified more cages with fur mites (MB and MC) than direct PCR when cellulose bedding was used; and was better at detecting parasites than all nonmolecular methods evaluated. PCR analysis of filter media extract was superior to swab and direct PCR for all parasites cumulatively for each bedding type. Direct PCR more effectively detected MC and all parasites combined for aspen chip compared with cellulose bedding. PCR analysis of filter media extract for IVC systems in which exhaust air is filtered at the cage level was shown to be a highly effective environmental testing method.
Yeh, Chia-Hsien; Zhao, Zi-Qi; Shen, Pi-Lan; Lin, Yu-Cheng
2014-01-01
This study presents an optical inspection system for detecting a commercial point-of-care testing product and a new detection model covering from qualitative to quantitative analysis. Human chorionic gonadotropin (hCG) strips (cut-off value of the hCG commercial product is 25 mIU/mL) were the detection target in our study. We used a complementary metal-oxide semiconductor (CMOS) sensor to detect the colors of the test line and control line in the specific strips and to reduce the observation errors by the naked eye. To achieve better linearity between the grayscale and the concentration, and to decrease the standard deviation (increase the signal to noise ratio, S/N), the Taguchi method was used to find the optimal parameters for the optical inspection system. The pregnancy test used the principles of the lateral flow immunoassay, and the colors of the test and control line were caused by the gold nanoparticles. Because of the sandwich immunoassay model, the color of the gold nanoparticles in the test line was darkened by increasing the hCG concentration. As the results reveal, the S/N increased from 43.48 dB to 53.38 dB, and the hCG concentration detection increased from 6.25 to 50 mIU/mL with a standard deviation of less than 10%. With the optimal parameters to decrease the detection limit and to increase the linearity determined by the Taguchi method, the optical inspection system can be applied to various commercial rapid tests for the detection of ketamine, troponin I, and fatty acid binding protein (FABP). PMID:25256108
PCR Testing of IVC Filter Tops as a Method for Detecting Murine Pinworms and Fur Mites
Gerwin, Philip M; Arbona, Rodolfo J Ricart; Riedel, Elyn R; Henderson, Kenneth S; Lipman, Neil S
2017-01-01
We evaluated PCR testing of filter tops from cages maintained on an IVC system through which exhaust air is filtered at the cage level as a method for detecting parasite- infected and -infested cages. Cages containing 4 naïve Swiss Webster mice received 360 mL of uncontaminated aspen chip or α-cellulose bedding (n = 18 cages each) and 60 mL of the same type of bedding weekly from each of the following 4 groups of cages housing mice infected or infested with Syphacia obvelata (SO), Aspiculuris tetraptera (AT), Myocoptes musculinus (MC), or Myobia musculi (MB) and Radfordia affinis (RA; 240 mL bedding total). Detection rates were compared at 30, 60, and 90 d after initiating bedding exposure, by using PCR analysis of filter tops (media extract and swabs) and testing of mouse samples (fur swab [direct] PCR testing, fecal flotation, anal tape test, direct examination of intestinal contents, and skin scrape). PCR testing of filter media extract detected 100% of all parasites at 30 d (both bedding types) except for AT (α-cellulose bedding, 67% detection rate); identified more cages with fur mites (MB and MC) than direct PCR when cellulose bedding was used; and was better at detecting parasites than all nonmolecular methods evaluated. PCR analysis of filter media extract was superior to swab and direct PCR for all parasites cumulatively for each bedding type. Direct PCR more effectively detected MC and all parasites combined for aspen chip compared with cellulose bedding. PCR analysis of filter media extract for IVC systems in which exhaust air is filtered at the cage level was shown to be a highly effective environmental testing method. PMID:29256370
Stafylis, Chrysovalantis; Klausner, Jeffrey D
2017-01-01
Fourth generation assays detect simultaneously antibodies for HIV and the p24 antigen, identifying HIV infection earlier than previous generation tests. Previous studies have shown that the Alere Determine HIV-1/2 Combo has lower than anticipated performance in detecting antibodies for HIV and the p24 antigen. Furthermore, there are currently very few studies evaluating the performance of Standard Diagnostics BIOLINE HIV Ag/Ab Combo. To evaluate the performance of the Alere Determine HIV-1/2 Combo and the Standard Diagnostics BIOLINE HIV Ag/Ab Combo in a panel of frozen serum samples. The testing panel included 133 previously frozen serum specimens from the UCLA Clinical Microbiology & Immunoserology laboratory. Reference testing included testing for HIV antibodies by a 3rd generation enzyme immunoassay followed by HIV RNA detection. Antibody negative and RNA positive sera were also tested by a laboratory 4th generation HIV Ab/Ag enzyme immunoassay. Reference testing yielded 97 positives for HIV infection and 36 negative samples. Sensitivity of the Alere test was 95% (88-98%), while the SD Bioline sensitivity was 91% (83-96%). Both assays showed 100% (90-100%) specificity. No indeterminate or invalid results were recorded. Among 13 samples with acute infection (HIV RNA positive, HIV antibody negative), 12 were found positive by the first assay and 8 by the second. The antigen component of the Alere assay detected 10 acute samples, while the SD Bioline assay detected only one. Both rapid assays showed very good overall performance in detecting HIV infection in frozen serum samples, but further improvements are required to improve the performance in acute infection.
Multisignal detecting system of pile integrity testing
NASA Astrophysics Data System (ADS)
Liu, Zuting; Luo, Ying; Yu, Shihai
2002-05-01
The low strain reflection wave method plays a principal rule in the integrating detection of base piles. However, there are some deficiencies with this method. For example, there is a blind area of detection on top of the tested pile; it is difficult to recognize the defects at deep-seated parts of the pile; there is still the planar of 3D domino effect, etc. It is very difficult to solve these problems only with the single-transducer pile integrity testing system. A new multi-signal piles integrity testing system is proposed in this paper, which is able to impulse and collect signals on multiple points on top of the pile. By using the multiple superposition data processing method, the detecting system can effectively restrain the interference and elevate the precision and SNR of pile integrity testing. The system can also be applied to the evaluation of engineering structure health.
Lippi, Giuseppe; Pasalic, Leonardo; Favaloro, Emmanuel J
2015-08-01
Although assessment of prior personal and familial bleeding history is an important aspect of the diagnosis of bleeding disorders, patients with mild inherited bleeding disorders are sometimes clinically asymptomatic until presented with a hemostatic challenge. However, bleeding may occur after incursion of trauma or surgery, so detection of these conditions reflects an important facet of clinical and laboratory practice. Mild bleeding disorders may be detected as a result of family studies or following identification of abnormal values in first-line screening tests such as activated partial thromboplastin time, prothrombin time, fibrinogen and global platelet function screen testing, such as the platelet function analyzer. Following determination of abnormal screening tests, subsequent investigation should follow a systematic approach that targets specific diagnostic tests, and including factor assays, full platelet function assays and more extensive specialized hemostasis testing. The current report provides a personal overview on inherited disorders of blood coagulation and their detection.
Mallet, Laurent; Gisonni-Lex, Lucy
2014-01-01
From an industrial perspective, the conventional in vitro and in vivo assays used for detection of viral contaminants have shown their limitations, as illustrated by the unfortunate detection of porcine circovirus contamination in a licensed rotavirus vaccine. This contamination event illustrates the gaps within the existing adventitious agent strategy and the potential use of new broader molecular detection methods. This paper serves to summarize current testing approaches and challenges, along with opportunities for the use of these new technologies. Testing of biological products is required to ensure the safety of patients. Recently, a licensed vaccine was found to be contaminated with a virus. This contamination did not cause a safety concern to the patients; however, it highlights the need for using new testing methods to control our biological products. This paper introduces the benefits of these new tests and outlines the challenges with the current tests. © PDA, Inc. 2014.
Portable fixture facilitates pressure testing of instrumentation fittings
NASA Technical Reports Server (NTRS)
Olson, G. A.
1967-01-01
Portable fixture facilitates pressure testing to detect possible leaks in instrumentation fittings mounted on tank bulkheads. It uses a vacuum cup which seals a pressure regulator adapter around one side of the fitting to be pressure tested. Leakage is detected with a gas sniffer.
Ho, Karen S; Twede, Hope; Vanzo, Rena; Harward, Erin; Hensel, Charles H; Martin, Megan M; Page, Stephanie; Peiffer, Andreas; Mowery-Rushton, Patricia; Serrano, Moises; Wassman, E Robert
2016-01-01
Copy number variants (CNVs) as detected by chromosomal microarray analysis (CMA) significantly contribute to the etiology of neurodevelopmental disorders, such as developmental delay (DD), intellectual disability (ID), and autism spectrum disorder (ASD). This study summarizes the results of 3.5 years of CMA testing by a CLIA-certified clinical testing laboratory 5487 patients with neurodevelopmental conditions were clinically evaluated for rare copy number variants using a 2.8-million probe custom CMA optimized for the detection of CNVs associated with neurodevelopmental disorders. We report an overall detection rate of 29.4% in our neurodevelopmental cohort, which rises to nearly 33% when cases with DD/ID and/or MCA only are considered. The detection rate for the ASD cohort is also significant, at 25%. Additionally, we find that detection rate and pathogenic yield of CMA vary significantly depending on the primary indications for testing, the age of the individuals tested, and the specialty of the ordering doctor. We also report a significant difference between the detection rate on the ultrahigh resolution optimized array in comparison to the array from which it originated. This increase in detection can significantly contribute to the efficient and effective medical management of neurodevelopmental conditions in the clinic.
Bin, Yu; Li, Zhongan; Wu, Jianxiang; Wang, Xuefeng; Zhou, Yan; Li, Taisheng; Yang, Fangyun; Zhou, Changyong; Song, Zhen
2018-02-01
A rapid immunochromatographic strip (ICS) test for detection of citrus yellow vein clearing virus (CYVCV) was developed. The test is based on an antibody sandwich format and uses the monoclonal antibody (MAb) 1E1, which is specific for CYVCV. MAb 1E1 labeled with 30-nm colloidal gold particles was coated on a gold conjugate pad. A secondary goat anti-mouse IgG was coated on the surface of a nitrocellulose filter membrane (NC) as the control (C) line, while 1E1 was coated on the surface of the NC as the test (T) line. The ICS test was evaluated for specificity and sensitivity and then applied for virus detection in field samples. There was no cross-reaction with citrus tristeza virus (CTV), satsuma dwarf virus (SDV), citrus tatter leaf virus (CTLV), citrus exocortis viroid (CEVd), citrus mosaic virus (CiMV), citrus psorosis virus (CPV), citrus ringspot virus (RSV) or 'Candidatus Liberibacter asiaticus' (CLas). The ICS test was still able to detect CYVCV in tissue extracts at a dilution of 1: 320 (w/v), which is as efficient as the dot-ELISA assay. In general, the ICS assay is less expensive, faster and simpler to conduct than conventional CYVCV detection methods, so it may be useful for large-scale detection or monitoring of CYVCV.
Martin, B A; Branch, D W; Rodgers, G M
1996-01-01
Increasing dilutions of lupus anticoagulant (LA) plasmas from twelve patients were used to directly compare the sensitivity of four tests for LA. The tests evaluated were the modified Bell and Alton activated partial thromboplastin time (APTT), an APTT using a commercially prepared partial thromboplastin (Platelin LS APTT), a modified dilute Russell's viper venom time (DRVVT), and a modified kaolin clotting time (KCT). LAs were detected in all twelve plasmas by each of three tests and eleven of twelve plasmas in a fourth test when undiluted patient plasma was used. Repeating the tests after diluting the LA plasmas with normal platelet-free plasma (PFP) showed that the KCT was the most sensitive test for LA, detecting eleven of twelve LAs at a dilution of 10% patient plasma and ten of twelve LAs at a dilution of 5% patient plasma. The modified Bell and Alton APTT and the modified DRVVT had similar sensitivities at a patient plasma concentration of 10%, detecting seven of twelve and eight of twelve LAs, respectively. The Platelin LS APTT detected only four of twelve LAs at a patient plasma concentration of 10%. Our results indicate that the modified KCT is a sensitive method for the detection of LAs. The modified Bell and Alton APTT and the DRVVT were less sensitive.
Code of Federal Regulations, 2010 CFR
2010-04-01
... testing of new or modified explosive materials; (2) Training in explosives detection or development or testing of explosives detection equipment; or (3) Forensic science purposes; or (b) Was plastic explosive...
Rapid Detection of the Varicella Zoster Virus
NASA Technical Reports Server (NTRS)
Lewis, Michelle P.; Harding, Robert
2011-01-01
1.Technology Description-Researchers discovered that when the Varicella Zoster Virus (VZV) reactivates from latency in the body, the virus is consistently present in saliva before the appearance of skin lesions. A small saliva sample is mixed with a specialized reagent in a test kit. If the virus is present in the saliva sample, the mixture turns a red color. The sensitivity and specificity emanates from an antibody-antigen reaction. This technology is a rapid, non-invasive, point of-of-care testing kit for detecting the virus from a saliva sample. The device is easy to use and can be used in clinics and in remote locations to quickly detect VZV and begin treatment with antiviral drugs. 2.Market Opportunity- RST Bioscience will be the first and only company to market a rapid, same day test kit for the detection of VZV in saliva. The RST detection test kit will have several advantages over existing, competitive technology. The test kit is self contained and laboratory equipment is not required for analysis of the sample. Only a single saliva sample is required to be taken instead of blood or cerebral spinal fluid. The test kit is portable, sterile and disposable after use. RST detection test kits require no electrical power or expensive storage equipment and can be used in remote locations. 3.Market Analysis- According to the CDC, it is estimated that 1 million cases of shingles occur each year in the U.S. with more than half over the age of sixty. There is a high demand for rapid diagnostics by the public. The point-of-care testing (POCT) market is growing faster than other segments of in vitro diagnostics. According to a July 2007 InteLab Corporation industry report the overall market for POCT was forecast to increase from $10.3 billion in 2005 to $18.7 billion by 2011. The market value of this test kit has not been determined. 4.Competition- The VZV vaccine prevents 50% of cases and reduces neuralgia by 66%. The most popular test detects VZV-specific IgM antibody in blood. Other tests include running a sample in a polymerase chain reaction analyzer, enzyme immunoassay, latex agglutination, indirect fluorescent antibody and fluorescent antibody to membrane antigen assay. These existing tests require laboratory analysis by trained personnel, expensive equipment, invasive procedures and a longer period of time to obtain test results.
Optical Production and Detection of Ultrasonic Waves in Metals for Nondestructive Testing
NASA Technical Reports Server (NTRS)
Morrison, R. A.
1972-01-01
Ultrasonic waves were produced by striking the surface of a metal with the focused one-joule pulse of a Q-switched ruby laser. Rayleigh (surface) waves and longitudinal waves were detected with conventional transducers. Optical methods of detection were tested and developed. Rayleigh waves were produced with an oscillator and transducer. They were optically detected on curved polished surfaces, and on unpolished surfaces. The technique uses a knife edge to detect small angle changes of the surface as the wave pulse passes the illuminated spot. Optical flaw detection using pulse echo and attenuation is demonstrated.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lavan, C.K. Jr.
1996-10-01
Loral Defense Systems-Akron (LDSA) has developed a laser-based mine detection system in response to the US Navy`s requirements for detecting, localizing and classifying mines in deep water shipping channels. This sensor system was tested recently at the Navy`s David Taylor Research Center (DTRC) at Bethesda, MD and at the US Army`s Camp Perry near Lake Erie. The testing at Camp Perry involved installation of the sensor system on the Goodyear Tim & Rubber Company`s airship {open_quotes}Spirit of Akron{close_quotes} and the conduct of control flight test experiments over Lake Erie. Resultant imagery has been analyzed in terms of water optical properties.more » Further tests are planned in a multispectral mode incorporating both active illumination and passive detection. The system can be extended to the detection of Unexploded Ordnance (UXO) in government test ranges and to detection of other devices both buried and at the surface. The utility of the airship (blimp) makes the approach practical due to long endurance, wide speed range and platform flexibility. 14 figs.« less
Translating bacterial detection by DNAzymes into a litmus test.
Tram, Kha; Kanda, Pushpinder; Salena, Bruno J; Huan, Shuangyan; Li, Yingfu
2014-11-17
Microbial pathogens pose serious threats to public health and safety, and results in millions of illnesses and deaths as well as huge economic losses annually. Laborious and expensive pathogen tests often represent a significant hindrance to implementing effective front-line preventative care, particularly in resource-limited regions. Thus, there is a significant need to develop low-cost and easy-to-use methods for pathogen detection. Herein, we present a simple and inexpensive litmus test for bacterial detection. The method takes advantage of a bacteria-specific RNA-cleaving DNAzyme probe as the molecular recognition element and the ability of urease to hydrolyze urea and elevate the pH value of the test solution. By coupling urease to the DNAzyme on magnetic beads, the detection of bacteria is translated into a pH increase, which can be readily detected using a litmus dye or pH paper. The simplicity, low cost, and broad adaptability make this litmus test attractive for field applications, particularly in the developing world. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Mohanty, Sujit K; Yu, Chi Li; Gopishetty, Sridhar; Subramanian, Mani
2014-08-06
Excess consumption of caffeine (>400 mg/day/adult) can lead to adverse health effects. Recent introduction of caffeinated products (gums, jelly beans, energy drinks) might lead to excessive consumption, especially among children and nursing mothers, hence attracting the Food and Drug Administration's attention and product withdrawals. An "in-home" test will aid vigilant consumers in detecting caffeine in beverages and milk easily and quickly, thereby restricting its consumption. Known diagnostic methods lack speed and sensitivity. We report a caffeine dehydrogenase (Cdh)-based test which is highly sensitive (1-5 ppm) and detects caffeine in beverages and mother's milk in 1 min. Other components in these complex test samples do not interfere with the detection. Caffeine-dependent reduction of the dye iodonitrotetrazolium chloride results in shades of pink proportional to the levels in test samples. This test also estimates caffeine levels in pharmaceuticals, comparable to high-performance liquid chromatography. The Cdh-based test is the first with the desired attributes of a rapid and robust caffeine diagnostic kit.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Passarge, M; Fix, M K; Manser, P
Purpose: To create and test an accurate EPID-frame-based VMAT QA metric to detect gross dose errors in real-time and to provide information about the source of error. Methods: A Swiss cheese model was created for an EPID-based real-time QA process. The system compares a treatmentplan- based reference set of EPID images with images acquired over each 2° gantry angle interval. The metric utilizes a sequence of independent consecutively executed error detection Methods: a masking technique that verifies infield radiation delivery and ensures no out-of-field radiation; output normalization checks at two different stages; global image alignment to quantify rotation, scaling andmore » translation; standard gamma evaluation (3%, 3 mm) and pixel intensity deviation checks including and excluding high dose gradient regions. Tolerances for each test were determined. For algorithm testing, twelve different types of errors were selected to modify the original plan. Corresponding predictions for each test case were generated, which included measurement-based noise. Each test case was run multiple times (with different noise per run) to assess the ability to detect introduced errors. Results: Averaged over five test runs, 99.1% of all plan variations that resulted in patient dose errors were detected within 2° and 100% within 4° (∼1% of patient dose delivery). Including cases that led to slightly modified but clinically equivalent plans, 91.5% were detected by the system within 2°. Based on the type of method that detected the error, determination of error sources was achieved. Conclusion: An EPID-based during-treatment error detection system for VMAT deliveries was successfully designed and tested. The system utilizes a sequence of methods to identify and prevent gross treatment delivery errors. The system was inspected for robustness with realistic noise variations, demonstrating that it has the potential to detect a large majority of errors in real-time and indicate the error source. J. V. Siebers receives funding support from Varian Medical Systems.« less
A comparison of two ELISAs for the detection of antibodies to bovine leucosis virus in bulk-milk.
Ridge, S E; Galvin, J W
2005-07-01
To estimate the sensitivity, specificity and detection limits for two bulk-milk enzyme-linked immunosorbent assays, the Svanovir BLV-gp51-Ab and the Lactelisa BLV Ab Bi indirect tank 250, for the detection of antibody to bovine leucosis virus in milk. Milk samples from 27 cows known to have enzootic bovine leucosis (EBL) were serially diluted with milk from a herd known to be free from the disease. The dilution at which antibodies could no longer be detected by each test was determined. A total of 1959 bulk-milk samples submitted to a laboratory for the Victorian (EBL) eradication program were tested with both the Svanovir and the Lactelisa assays. A Bayesian approach was used to calculate maximum-likelihood estimates of test sensitivity and specificity. An additional 660 bulk-milk samples were tested with both the Svanovir and the Lactelisa assays. Herds that had positive results on either or both of the assays were subjected to blood or milk testing of individual cattle. The dilution of milk at which the Svanovir assay failed to detect enzootic bovine leucosis antibody in half of the samples was 1 in 40, whereas the comparable value for the Lactelisa was 1 in 200. Computer modeling of the operating characteristics of the Svanovir assay indicated that the sensitivity of that assay would be considerably lower than that for the Lactelisa, and the specificity was estimated to be higher. Evaluation of the assays using 660 bulk-milk samples showed that the Lactelisa assay detected four infected herds that were not detected by the Svanovir test. No false positive results were recorded for either assay. Use of the Lactelisa assay in the Victorian EBL eradication program will enhance disease detection and eradication, but may also result in an increased frequency of false positive bulk-milk test results.
The Impact of Conditional Scores on the Performance of DETECT.
ERIC Educational Resources Information Center
Zhang, Yanwei Oliver; Yu, Feng; Nandakumar, Ratna
DETECT is a nonparametric, conditional covariance-based procedure to identify dimensional structure and the degree of multidimensionality of test data. The ability composite or conditional score used to estimate conditional covariance plays a significant role in the performance of DETECT. The number correct score of all items in the test (T) and…
Pollet-Villard, Marie; Cartier, Régine; Gaucherand, Pascal; Doret, Muriel
2011-06-01
We compared two biochemical tests of premature rupture of membranes (PROM) in vitro: Actim PROM (Medix Biochemica, Kauniainen, Finland), which detects insulin-like growth factor binding protein-1, and AmniSure (AmniSure International LLC, Cambridge, MA), which detects placental alpha microglobulin-1. Samples of amniotic fluid were collected during caesarean section in 41 patients. A dilution series was prepared and both tests were performed twice at each dilution. Sensitivity, detection limit, response time, and reproducibility of both tests were compared. Both tests' sensitivity was 100% at dilution 1:10 and 1:20. AmniSure sensitivity was higher at dilution 1:40 and 1:80 ( P < 0.05). In 29 of 40 cases, AmniSure had a lower detection limit than Actim PROM. AmniSure response times were shorter and reproducibility was higher than Actim PROM ( P < 0.05). AmniSure had a lower detection limit of amniotic fluid than Actim PROM, with a shorter response time, a higher sensitivity, and a better reproducibility. © Thieme Medical Publishers.
Research on Abnormal Detection Based on Improved Combination of K - means and SVDD
NASA Astrophysics Data System (ADS)
Hao, Xiaohong; Zhang, Xiaofeng
2018-01-01
In order to improve the efficiency of network intrusion detection and reduce the false alarm rate, this paper proposes an anomaly detection algorithm based on improved K-means and SVDD. The algorithm first uses the improved K-means algorithm to cluster the training samples of each class, so that each class is independent and compact in class; Then, according to the training samples, the SVDD algorithm is used to construct the minimum superspheres. The subordinate relationship of the samples is determined by calculating the distance of the minimum superspheres constructed by SVDD. If the test sample is less than the center of the hypersphere, the test sample belongs to this class, otherwise it does not belong to this class, after several comparisons, the final test of the effective detection of the test sample.In this paper, we use KDD CUP99 data set to simulate the proposed anomaly detection algorithm. The results show that the algorithm has high detection rate and low false alarm rate, which is an effective network security protection method.
Enhanced urinalysis in the detection of asymptomatic bacteriuria in pregnancy.
Aigere, E O S; Okusanya, B O; Eigbefoh, J O; Okome, G B O
2013-01-01
Detection and treatment of asymptomatic bacteriuria (ASB) in pregnancy is important to avert the attendant maternal and fetal morbidity. Other than urine culture, no other screening test is unequivocal. The use of enhanced urinalysis test to detect ASB in pregnancy was investigated. This was a prospective observational study which compared enhanced urinalysis with dipstick tests and urine culture. Clean catch midstream urine specimen was collected from 150 consecutive asymptomatic pregnant women. Tests of validity were used for comparison. Enhanced urinalysis detected bacteriuria as much as urine culture (4% vs. 4.7%). Itwas 57.1% sensitive and 98.6% specific. It had a false negative rate of 42.9% and was 96.7% accurate when compared to urine culture. Enhanced urinalysis took 1-2 hours to be done and required skills to use the microscope and was more expensive than dipstick urinalysis. The accuracy of enhanced urinalysis and its ability to detect ASB as much as urine culture connotes that it can be used to detect asymptomatic bacteriuria in pregnancy albeit only in secondary and tertiary health centres because of the cost and technicality involved.
Evaluation of Polymerase Chain Reaction for Detecting Coliform Bacteria in Drinking Water Sources
Isfahani, Bahram Nasr; Fazeli, Hossein; Babaie, Zeinab; Poursina, Farkhondeh; Moghim, Sharareh; Rouzbahani, Meisam
2017-01-01
Background: Coliform bacteria are used as indicator organisms for detecting fecal pollution in water. Traditional methods including microbial culture tests in lactose-containing media and enzyme-based tests for the detection of β-galactosidase; however, these methods are time-consuming and less specific. The aim of this study was to evaluate polymerase chain reaction (PCR) for detecting coliform. Materials and Methods: Totally, 100 of water samples from Isfahan drinking water source were collected. Coliform bacteria and Escherichia coli were detected in drinking water using LacZ and LamB genes in PCR method performed in comparison with biochemical tests for all samples. Results: Using phenotyping, 80 coliform isolates were found. The results of the biochemical tests illustrated 78.7% coliform bacteria and 21.2% E. coli. PCR results for LacZ and LamB genes were 67.5% and 17.5%, respectively. Conclusion: The PCR method was shown to be an effective, sensitive, and rapid method for detecting coliform and E. coli in drinking water from the Isfahan drinking water sources. PMID:29142893
Rapid detection of EBOLA VP40 in microchip immunofiltration assay
NASA Astrophysics Data System (ADS)
Miethe, Peter; Gary, Dominik; Hlawatsch, Nadine; Gad, Anne-Marie
2015-05-01
In the spring of 2014, the Ebola virus (EBOV) strain Zaire caused a dramatic outbreak in several regions of West Africa. The RT-PCR and antigen capture diagnostic proved to be effective for detecting EBOV in blood and serum. In this paper, we present data of a rapid antigen capture test for the detection of VP40. The test was performed in a microfluidic chip for immunofiltration analysis. The chip integrates all necessary assay components. The analytical sensitivity of the rapid test was 8 ng/ml for recombinant VP40. In serum and whole blood samples spiked with virus culture material, the detection limit was 2.2 x 102 PFU/ml. The performance data of the rapid test (15 min) are comparable to that of the VP40 laboratory ELISA.
Method and apparatus for automatically detecting patterns in digital point-ordered signals
Brudnoy, David M.
1998-01-01
The present invention is a method and system for detecting a physical feature of a test piece by detecting a pattern in a signal representing data from inspection of the test piece. The pattern is detected by automated additive decomposition of a digital point-ordered signal which represents the data. The present invention can properly handle a non-periodic signal. A physical parameter of the test piece is measured. A digital point-ordered signal representative of the measured physical parameter is generated. The digital point-ordered signal is decomposed into a baseline signal, a background noise signal, and a peaks/troughs signal. The peaks/troughs from the peaks/troughs signal are located and peaks/troughs information indicating the physical feature of the test piece is output.
Method and apparatus for automatically detecting patterns in digital point-ordered signals
Brudnoy, D.M.
1998-10-20
The present invention is a method and system for detecting a physical feature of a test piece by detecting a pattern in a signal representing data from inspection of the test piece. The pattern is detected by automated additive decomposition of a digital point-ordered signal which represents the data. The present invention can properly handle a non-periodic signal. A physical parameter of the test piece is measured. A digital point-ordered signal representative of the measured physical parameter is generated. The digital point-ordered signal is decomposed into a baseline signal, a background noise signal, and a peaks/troughs signal. The peaks/troughs from the peaks/troughs signal are located and peaks/troughs information indicating the physical feature of the test piece is output. 14 figs.
Anti-E Detected in a 7-Month-Old Infant with Acute Lymphoblastic Leukemia after Transfusion.
Kumeta, Mai; Tanaka, Kazuto; Kaneko, Natsuki; Osanai, Takayuki; Ajima, Hikaru; Tamai, Yoshiko; Kayaba, Hiroyuki; Ito, Etsuro; Saito, Norihiro
2018-06-01
Only a few cases of infantile anti-red blood cell alloantibody production have been reported. A 7-month-old girl with acute lymphoid leukemia developed anti-E alloantibody 13 days after transfusion of E-positive red blood cells. Antibody screening was performed before and at 2, 6, 13, 18, 27, 34, and 49 days after red blood cell transfusion. Identification test, direct immunoglobulin test, acid elution, and dithiothreitol test were also performed. Anti-E alloantibody was detected in the blood 13 days after the first transfusion. The detected antibody was IgM and it decreased below detectable levels within 49 days after the first transfusion. Follow-up testing for the presence of post-transfusion alloantibody at appropriate times is important, even in infants.
The Gap Detection Test: Can It Be Used to Diagnose Tinnitus?
Boyen, Kris; Başkent, Deniz
2015-01-01
Objectives: Animals with induced tinnitus showed difficulties in detecting silent gaps in sounds, suggesting that the tinnitus percept may be filling the gap. The main purpose of this study was to evaluate the applicability of this approach to detect tinnitus in human patients. The authors first hypothesized that gap detection would be impaired in patients with tinnitus, and second, that gap detection would be more impaired at frequencies close to the tinnitus frequency of the patient. Design: Twenty-two adults with bilateral tinnitus, 20 age-matched and hearing loss–matched subjects without tinnitus, and 10 young normal-hearing subjects participated in the study. To determine the characteristics of the tinnitus, subjects matched an external sound to their perceived tinnitus in pitch and loudness. To determine the minimum detectable gap, the gap threshold, an adaptive psychoacoustic test was performed three times by each subject. In this gap detection test, four different stimuli, with various frequencies and bandwidths, were presented at three intensity levels each. Results: Similar to previous reports of gap detection, increasing sensation level yielded shorter gap thresholds for all stimuli in all groups. Interestingly, the tinnitus group did not display elevated gap thresholds in any of the four stimuli. Moreover, visual inspection of the data revealed no relation between gap detection performance and perceived tinnitus pitch. Conclusions: These findings show that tinnitus in humans has no effect on the ability to detect gaps in auditory stimuli. Thus, the testing procedure in its present form is not suitable for clinical detection of tinnitus in humans. PMID:25822647
ERIC Educational Resources Information Center
McLeod, Lori D.; Lewis, Charles; Thissen, David.
With the increased use of computerized adaptive testing, which allows for continuous testing, new concerns about test security have evolved, one being the assurance that items in an item pool are safeguarded from theft. In this paper, the risk of score inflation and procedures to detect test takers using item preknowledge are explored. When test…
Rapid Diagnostic Tests for Identifying Avian Influenza A(H7N9) Virus in Clinical Samples
Chen, Yu; Wang, Dayan; Zheng, Shufa; Shu, Yuelong; Chen, Wenxiang; Cui, Dawei; Li, Jinming; Yu, Hongjie; Wang, Yu; Li, Lanjuan
2015-01-01
To determine sensitivity of rapid diagnostic tests for detecting influenza A(H7N9) virus, we compared rapid tests with PCR results and tested different types of clinical samples. Usefulness of seasonal influenza rapid tests for A(H7N9) virus infections is limited because of their low sensitivity for detecting virus in upper respiratory tract specimens. PMID:25529064
Mitchell, J M; Yee, A J; McNab, W B; Griffiths, M W; McEwen, S A
1999-01-01
LacTek tests are competitive enzyme-linked immunosorbent assays intended for rapid detection of antimicrobial residues in bovine milk. In this study, the LacTek test protocol was modified for use with extracts of bovine tissue to detect beta-lactam, tetracycline, and sulfamethazine residues. Test performance characteristics--precision, accuracy, ruggedness, practicability, and analytical specificity and sensitivity--were investigated. Results suggest that LacTek tests can be easily adapted to detect antimicrobial residues in extracts of lean ground beef. However, positive samples may not contain residues at violative concentrations (i.e., Canadian maximum residue limits), and therefore, additional analysis would be required for final confirmation and quantitation (e.g., chromatography).
Theory of chromatic noise masking applied to testing linearity of S-cone detection mechanisms.
Giulianini, Franco; Eskew, Rhea T
2007-09-01
A method for testing the linearity of cone combination of chromatic detection mechanisms is applied to S-cone detection. This approach uses the concept of mechanism noise, the noise as seen by a postreceptoral neural mechanism, to represent the effects of superposing chromatic noise components in elevating thresholds and leads to a parameter-free prediction for a linear mechanism. The method also provides a test for the presence of multiple linear detectors and off-axis looking. No evidence for multiple linear mechanisms was found when using either S-cone increment or decrement tests. The results for both S-cone test polarities demonstrate that these mechanisms combine their cone inputs nonlinearly.
Comparison of molecular tests for the diagnosis of malaria in Honduras
2012-01-01
Background Honduras is a tropical country with more than 70% of its population living at risk of being infected with either Plasmodium vivax or Plasmodium falciparum. Laboratory diagnosis is a very important factor for adequate treatment and management of malaria. In Honduras, malaria is diagnosed by both, microscopy and rapid diagnostic tests and to date, no molecular methods have been implemented for routine diagnosis. However, since mixed infections, and asymptomatic and low-parasitaemic cases are difficult to detect by light microscopy alone, identifying appropriate molecular tools for diagnostic applications in Honduras deserves further study. The present study investigated the utility of different molecular tests for the diagnosis of malaria in Honduras. Methods A total of 138 blood samples collected as part of a clinical trial to assess the efficacy of chloroquine were used: 69 microscopically confirmed P. falciparum positive samples obtained on the day of enrolment and 69 follow-up samples obtained 28 days after chloroquine treatment and shown to be malaria negative by microscopy. Sensitivity and specificity of microscopy was compared to an 18 s ribosomal RNA gene-based nested PCR, two single-PCR reactions designed to detect Plasmodium falciparum infections, one single-PCR to detect Plasmodium vivax infections, and one multiplex one-step PCR reaction to detect both parasite species. Results Of the 69 microscopically positive P. falciparum samples, 68 were confirmed to be P. falciparum-positive by two of the molecular tests used. The one sample not detected as P. falciparum by any of the molecular tests was shown to be P. vivax-positive by a reference molecular test indicating a misdiagnosis by microscopy. The reference molecular test detected five cases of P. vivax/P. falciparum mixed infections, which were not recognized by microscopy as mixed infections. Only two of these mixed infections were recognized by a multiplex test while a P. vivax-specific polymerase chain reaction (PCR) detected three of them. In addition, one of the day 28 samples, previously determined to be malaria negative by microscopy, was shown to be P. vivax-positive by three of the molecular tests specific for this parasite. Conclusions Molecular tests are valuable tools for the confirmation of Plasmodium species and in detecting mixed infections in malaria endemic regions. PMID:22513192
Comparison of molecular tests for the diagnosis of malaria in Honduras.
Fontecha, Gustavo A; Mendoza, Meisy; Banegas, Engels; Poorak, Mitra; De Oliveira, Alexandre M; Mancero, Tamara; Udhayakumar, Venkatachalam; Lucchi, Naomi W; Mejia, Rosa E
2012-04-18
Honduras is a tropical country with more than 70% of its population living at risk of being infected with either Plasmodium vivax or Plasmodium falciparum. Laboratory diagnosis is a very important factor for adequate treatment and management of malaria. In Honduras, malaria is diagnosed by both, microscopy and rapid diagnostic tests and to date, no molecular methods have been implemented for routine diagnosis. However, since mixed infections, and asymptomatic and low-parasitaemic cases are difficult to detect by light microscopy alone, identifying appropriate molecular tools for diagnostic applications in Honduras deserves further study. The present study investigated the utility of different molecular tests for the diagnosis of malaria in Honduras. A total of 138 blood samples collected as part of a clinical trial to assess the efficacy of chloroquine were used: 69 microscopically confirmed P. falciparum positive samples obtained on the day of enrollment and 69 follow-up samples obtained 28 days after chloroquine treatment and shown to be malaria negative by microscopy. Sensitivity and specificity of microscopy was compared to an 18 s ribosomal RNA gene-based nested PCR, two single-PCR reactions designed to detect Plasmodium falciparum infections, one single-PCR to detect Plasmodium vivax infections, and one multiplex one-step PCR reaction to detect both parasite species. Of the 69 microscopically positive P. falciparum samples, 68 were confirmed to be P. falciparum-positive by two of the molecular tests used. The one sample not detected as P. falciparum by any of the molecular tests was shown to be P. vivax-positive by a reference molecular test indicating a misdiagnosis by microscopy. The reference molecular test detected five cases of P. vivax/P. falciparum mixed infections, which were not recognized by microscopy as mixed infections. Only two of these mixed infections were recognized by a multiplex test while a P. vivax-specific polymerase chain reaction (PCR) detected three of them. In addition, one of the day 28 samples, previously determined to be malaria negative by microscopy, was shown to be P. vivax-positive by three of the molecular tests specific for this parasite. Molecular tests are valuable tools for the confirmation of Plasmodium species and in detecting mixed infections in malaria endemic regions.
NASA Astrophysics Data System (ADS)
Tejedor, J.; Macias-Guarasa, J.; Martins, H. F.; Piote, D.; Pastor-Graells, J.; Martin-Lopez, S.; Corredera, P.; De Pauw, G.; De Smet, F.; Postvoll, W.; Ahlen, C. H.; Gonzalez-Herraez, M.
2017-04-01
This paper presents the first report on on-line and final blind field test results of a pipeline integrity threat surveillance system. The system integrates a machine+activity identification mode, and a threat detection mode. Two different pipeline sections were selected for the blind tests: One close to the sensor position, and the other 35 km away from it. Results of the machine+activity identification mode showed that about 46% of the times the machine, the activity or both were correctly identified. For the threat detection mode, 8 out of 10 threats were correctly detected, with 1 false alarm.
Design of on line detection system for static evaporation rate of LNG vehicle cylinders
NASA Astrophysics Data System (ADS)
Tang, P.; Wang, M.; Tan, W. H.; Ling, Z. W.; Li, F.
2017-06-01
In order to solve the problems existing in the regular inspection of LNG vehicle cylinders, the static evaporation rate on line detection system of LNG cylinders is discussed in this paper. A non-disassembling, short-term and high-efficiency on line detection system for LNG vehicle cylinders is proposed, which can meet the requirement of evaporation rate test under different media and different test pressures. And then test methods under the experimental conditions, atmospheric pressure and pressure are given respectively. This online detection system designed in this paper can effectively solve the technical problems during the inspection of the cylinder.
High sensitivity pyrogen testing in water and dialysis solutions.
Daneshian, Mardas; Wendel, Albrecht; Hartung, Thomas; von Aulock, Sonja
2008-07-20
The dialysis patient is confronted with hundreds of litres of dialysis solution per week, which pass the natural protective barriers of the body and are brought into contact with the tissue directly in the case of peritoneal dialysis or indirectly in the case of renal dialysis (hemodialysis). The components can be tested for living specimens or dead pyrogenic (fever-inducing) contaminations. The former is usually detected by cultivation and the latter by the endotoxin-specific Limulus Amoebocyte Lysate Assay (LAL). However, the LAL assay does not reflect the response of the human immune system to the wide variety of possible pyrogenic contaminations in dialysis fluids. Furthermore, the test is limited in its sensitivity to detect extremely low concentrations of pyrogens, which in their sum result in chronic pathologies in dialysis patients. The In vitro Pyrogen Test (IPT) employs human whole blood to detect the spectrum of pyrogens to which humans respond by measuring the release of the endogenous fever mediator interleukin-1beta. Spike recovery checks exclude interference. The test has been validated in an international study for pyrogen detection in injectable solutions. In this study we adapted the IPT to the testing of dialysis solutions. Preincubation of 50 ml spiked samples with albumin-coated microspheres enhanced the sensitivity of the assay to detect contaminations down to 0.1 pg/ml LPS or 0.001 EU/ml in water or saline and allowed pyrogen detection in dialysis concentrates or final working solutions. This method offers high sensitivity detection of human-relevant pyrogens in dialysis solutions and components.
Doret, Muriel; Cartier, Régine; Miribel, Juliette; Massardier, Jérome; Massoud, Mona; Bordes, Agnès; Moret, Stéphanie; Gaucherand, Pascal
2013-12-01
Previable premature rupture of the membranes (pPROM), occurring before 24WG, is associated with a 25% neonatal survival rate. This terrible prognosis may lead to elective pregnancy termination on parents' request. Therefore, certain diagnosis is essential but remains difficult in about 10% of patients. Bed-side biochemical tests developed to help in diagnosis had never been evaluated in early pregnancies. This study aimed to evaluate and compare the in vitro sensitivity, detection limit, reaction time and consistency of AmniSure detecting placental alpha microglobulin-1 (PAMG-1) and actim PROM detecting Insulin Growth Factor Binding Protein-1 (IGFBP-1) in amniotic fluid between 15 and 20weeks of gestation (WG). Samples of amniotic fluid were collected by amniocentesis performed between 15 and 20 completed WG in 55 patients. Dilution series were prepared and both tests were performed twice at each dilution. In vitro sensitivity, detection limit, and reaction time were evaluated and compared in serial dilution. A total of 460 AmniSure and 476 actim PROM tests were performed. Both tests' in vitro sensitivity was 100% at dilution 1:20 and remained up to 90% until dilution 1:80. In vitro sensitivities were not different at any dilution. Detection limit and consistency were similar for both tests at all dilution. Actim PROM reaction time was shorter than AmniSure at all dilutions, except 1:320 (p<0.05). PAMG-1 and IGFBP-1 can be detected in amniotic fluid between 15 and 20 completed WG, using respectively AmniSure and actim PROM. © 2013.
A Smartphone App to Screen for HIV-Related Neurocognitive Impairment.
Robbins, Reuben N; Brown, Henry; Ehlers, Andries; Joska, John A; Thomas, Kevin G F; Burgess, Rhonda; Byrd, Desiree; Morgello, Susan
2014-02-01
Neurocognitive Impairment (NCI) is one of the most common complications of HIV-infection, and has serious medical and functional consequences. However, screening for it is not routine and NCI often goes undiagnosed. Screening for NCI in HIV disease faces numerous challenges, such as limited screening tests, the need for specialized equipment and apparatuses, and highly trained personnel to administer, score and interpret screening tests. To address these challenges, we developed a novel smartphone-based screening tool, NeuroScreen , to detect HIV-related NCI that includes an easy-to-use graphical user interface with ten highly automated neuropsychological tests. To examine NeuroScreen's : 1) acceptability among patients and different potential users; 2) test construct and criterion validity; and 3) sensitivity and specificity to detect NCI. Fifty HIV+ individuals were administered a gold-standard neuropsychological test battery, designed to detect HIV-related NCI, and NeuroScreen . HIV+ test participants and eight potential provider-users of NeuroScreen were asked about its acceptability. There was a high level of acceptability of NeuroScreen by patients and potential provider-users. Moderate to high correlations between individual NeuroScreen tests and paper-and-pencil tests assessing the same cognitive domains were observed. NeuroScreen also demonstrated high sensitivity to detect NCI. NeuroScreen, a highly automated, easy-to-use smartphone-based screening test to detect NCI among HIV patients and usable by a range of healthcare personnel could help make routine screening for HIV-related NCI feasible. While NeuroScreen demonstrated robust psychometric properties and acceptability, further testing with larger and less neurocognitively impaired samples is warranted.
NDT of railway components using induction thermography
NASA Astrophysics Data System (ADS)
Netzelmann, U.; Walle, G.; Ehlen, A.; Lugin, S.; Finckbohner, M.; Bessert, S.
2016-02-01
Induction or eddy current thermography is used to detect surface cracks in ferritic steel. The technique is applied to detect surface cracks in rails from a moving test car. Cracks were detected at a train speed between 2 and 15 km/h. An automated demonstrator system for testing railway wheels after production is described. While the wheel is rotated, a robot guides the detection unit consisting of inductor and infrared camera over the surface.
Social Eavesdropping: Can You Hear the Emotionality in a "Hello" That Is Not Meant for You?
Karthikeyan, Sethu; Ramachandra, Vijayachandra
2017-01-01
The study examined third-party listeners' ability to detect the Hellos spoken to prevalidated happy, neutral, and sad facial expressions. The average detection accuracies from the happy and sad (HS), happy and neutral (HN), and sad and neutral (SN) listening tests followed the average vocal pitch differences between the two sets of Hellos in each of the tests; HS and HN detection accuracies were above chance reflecting the significant pitch differences between the respective Hellos. The SN detection accuracy was at chance reflecting the lack of pitch difference between sad and neutral Hellos. As expected, the SN detection accuracy positively correlated with theory of mind; participating in these tests has been likened to the act of eavesdropping, which has been discussed from an evolutionary perspective. An unexpected negative correlation between the HS detection accuracy and the empathy quotient has been discussed with respect to autism research on empathy and pitch discrimination.
Evaluating 6 ricin field detection assays.
Slotved, Hans-Christian; Sparding, Nadja; Tanassi, Julia Tanas; Steenhard, Nina R; Heegaard, Niels H H
2014-01-01
This study presents data showing the performance of 6 commercial detection assays against ricin around concentrations specified as detection limits by the producers. A 2-fold dilution series of 20 ng/ml ricin was prepared and used for testing the lateral-flow kits: BADD, Pro Strips™, ENVI, RAID DX, Ricin BioThreat Alert, and IMASS™ device. Three of the 6 tested field assays (IMASS™ device, ENVI assay, and the BioThreat Alert assay) were able to detect ricin, although differences in the measured detection limits compared to the official detection limits and false-negative results were observed. We were not able to get the BADD, Pro Strips™, and RAID assays to function in our laboratory. We conclude that when purchasing a field responder assay, there is large variation in the specificity of the assays, and a number of in-house tests must be performed to ensure functionality.
Fast uncooled module 32×32 array of polycrystalline PbSe used for muzzle flash detection
NASA Astrophysics Data System (ADS)
Kastek, Mariusz; Dulski, Rafał; Trzaskawka, Piotr; Bieszczad, Grzegorz
2011-06-01
The paper presents some aspects of muzzle flash detection using low resolution polycrystalline PbSe uncooled 32×32 detectors array. This system for muzzle flash detection works in MWIR (3 - 5 microns) region and it is based on VPD (Vapor Phase Deposition) technology. The low density uncooled 32×32 array is suitable for being used in low cost IR imagers sensitive in the MWIR band with frame rates exceeding 1.000 Hz. The FPA detector, read-out electronics and processing electronics (allowing the implementation of some algorithms for muzzle flash detection) has been presented. The system has been tested at field test ground. Results of detection range measurement with two types of optical systems (wide and narrow field of view) have been shown. The initial results of testing of some algorithms for muzzle flash detection have been also presented.
Prevalence of antibodies to type A influenza virus in wild avian species using two serologic assays
Brown, Justin D.; Luttrell, M. Page; Berghaus, Roy D.; Kistler, Whitney; Keeler, Shamus P.; Howey, Andrea; Wilcox, Benjamin; Hall, Jeffrey S.; Niles, Larry; Dey, Amanda; Knutsen, Gregory; Fritz, Kristen; Stallknecht, David E.
2010-01-01
Serologic testing to detect antibodies to avian influenza (AI) virus has been an underused tool for the study of these viruses in wild bird populations, which traditionally has relied on virus isolation and reverse transcriptase-polymerase chain reaction (RT-PCR). In a preliminary study, a recently developed commercial blocking enzyme-linked immunosorbent assay (bELISA) had sensitivity and specificity estimates of 82% and 100%, respectively, for detection of antibodies to AI virus in multiple wild bird species after experimental infection. To further evaluate the efficacy of this commercial bELISA and the agar gel immunodiffusion (AGID) test for AI virus antibody detection in wild birds, we tested 2,249 serum samples collected from 62 wild bird species, representing 10 taxonomic orders. Overall, the bELISA detected 25.4% positive samples, whereas the AGID test detected 14.8%. At the species level, the bELISA detected as many or more positive serum samples than the AGID in all 62 avian species. The majority of positive samples, detected by both assays, were from species that use aquatic habitats, with the highest prevalence from species in the orders Anseriformes and Charadriiformes. Conversely, antibodies to AI virus were rarely detected in the terrestrial species. The serologic data yielded by both assays are consistent with the known epidemiology of AI virus in wild birds and published reports of host range based on virus isolation and RT-PCR. The results of this research are also consistent with the aforementioned study, which evaluated the performance of the bELISA and AGID test on experimental samples. Collectively, the data from these two studies indicate that the bELISA is a more sensitive serologic assay than the AGID test for detecting prior exposure to AI virus in wild birds. Based on these results, the bELISA is a reliable species-independent assay with potentially valuable applications for wild bird AI surveillance.
(Quickly) Testing the Tester via Path Coverage
NASA Technical Reports Server (NTRS)
Groce, Alex
2009-01-01
The configuration complexity and code size of an automated testing framework may grow to a point that the tester itself becomes a significant software artifact, prone to poor configuration and implementation errors. Unfortunately, testing the tester by using old versions of the software under test (SUT) may be impractical or impossible: test framework changes may have been motivated by interface changes in the tested system, or fault detection may become too expensive in terms of computing time to justify running until errors are detected on older versions of the software. We propose the use of path coverage measures as a "quick and dirty" method for detecting many faults in complex test frameworks. We also note the possibility of using techniques developed to diversify state-space searches in model checking to diversify test focus, and an associated classification of tester changes into focus-changing and non-focus-changing modifications.
Gombold, James; Karakasidis, Stephen; Niksa, Paula; Podczasy, John; Neumann, Kitti; Richardson, James; Sane, Nandini; Johnson-Leva, Renita; Randolph, Valerie; Sadoff, Jerald; Minor, Phillip; Schmidt, Alexander; Duncan, Paul; Sheets, Rebecca L.
2015-01-01
Viral vaccines and the cell substrates used to manufacture them are subjected to tests for adventitious agents, including viruses, which might contaminant them. Some of the compendial methods (in vivo and in vitro in cell culture) were established in the mid-20th century. These methods have not been subjected to current assay validation, as new methods would need to be. This study was undertaken to provide insight into the breadth (selectivity) and sensitivity (limit of detection) of the routine methods, two such validation parameters. Sixteen viral stocks were prepared and characterized. These stocks were tested in serial dilutions by the routine methods to establish which viruses were detected by which methods and above what limit of detection. Sixteen out of sixteen viruses were detected in vitro, though one (bovine viral diarrhea virus) required special conditions to detect and another (rubella virus) was detected with low sensitivity. Many were detected at levels below 1 TCID50 or PFU (titers were established on the production cell line in most cases). In contrast, in vivo, only 6/11 viruses were detected, and 4 of these were detected only at amounts one or more logs above 1 TCID50 or PFU. Only influenza virus and vesicular stomatitis virus were detected at lower amounts in vivo than in vitro. Given the call to reduce, refine, or replace (3 R's) the use of animals in product safety testing and the emergence of new technologies for the detection of viruses, a re-examination of the current adventitious virus testing strategies seems warranted. Suggested pathways forward are offered. PMID:24681273
Security From Detection (Vehicles)
2011-02-24
Tester ( TVT ) or other TOP 02-2-615A 24 February 2011 5 similar device. Color vision can be assessed using the seven Ishihara Pseudo...Isochromatic plates usually contained in the TVT . b. Personnel chosen as observers for aural detectability tests must also have hearing ability...Test Test Measurement Diagnostic Equipment TOP Test Operations Procedure TVT Titmus® Vision Tester USMC United States Marine Corps
Security from Detection (Vehicles)
2011-02-24
Tester ( TVT ) or other TOP 02-2-615A 24 February 2011 5 similar device. Color vision can be assessed using the seven Ishihara Pseudo...Isochromatic plates usually contained in the TVT . b. Personnel chosen as observers for aural detectability tests must also have hearing ability...Test Test Measurement Diagnostic Equipment TOP Test Operations Procedure TVT Titmus® Vision Tester USMC United States Marine Corps
ERIC Educational Resources Information Center
Grand, James A.; Golubovich, Juliya; Ryan, Ann Marie; Schmitt, Neal
2013-01-01
In organizational and educational practices, sensitivity reviews are commonly advocated techniques for reducing test bias and enhancing fairness. In the present paper, results from two studies are reported which investigate how effective individuals are at detecting problematic test content and the influence such content has on important testing…
USDA-ARS?s Scientific Manuscript database
Several serologic tests designed to detect antibodies to immunodominant Mycobacterium bovis antigens have recently emerged as ancillary tests for the detection of bovine tuberculosis in cattle, particularly when applied after injection of purified protein derivative (PPD) for skin test that signific...
Cho, Sun-Joo; Preacher, Kristopher J.; Bottge, Brian A.
2015-01-01
Multilevel modeling (MLM) is frequently used to detect group differences, such as an intervention effect in a pre-test–post-test cluster-randomized design. Group differences on the post-test scores are detected by controlling for pre-test scores as a proxy variable for unobserved factors that predict future attributes. The pre-test and post-test scores that are most often used in MLM are summed item responses (or total scores). In prior research, there have been concerns regarding measurement error in the use of total scores in using MLM. To correct for measurement error in the covariate and outcome, a theoretical justification for the use of multilevel structural equation modeling (MSEM) has been established. However, MSEM for binary responses has not been widely applied to detect intervention effects (group differences) in intervention studies. In this article, the use of MSEM for intervention studies is demonstrated and the performance of MSEM is evaluated via a simulation study. Furthermore, the consequences of using MLM instead of MSEM are shown in detecting group differences. Results of the simulation study showed that MSEM performed adequately as the number of clusters, cluster size, and intraclass correlation increased and outperformed MLM for the detection of group differences. PMID:29881032
Vasconcelos, Karla Anacleto de; Frota, Silvana Maria Monte Coelho; Ruffino-Netto, Antonio; Kritski, Afrânio Lineu
2018-04-01
To investigate early detection of amikacin-induced ototoxicity in a population treated for multidrug-resistant tuberculosis (MDR-TB), by means of three different tests: pure-tone audiometry (PTA); high-frequency audiometry (HFA); and distortion-product otoacoustic emission (DPOAE) testing. This was a longitudinal prospective cohort study involving patients aged 18-69 years with a diagnosis of MDR-TB who had to receive amikacin for six months as part of their antituberculosis drug regimen for the first time. Hearing was assessed before treatment initiation and at two and six months after treatment initiation. Sequential statistics were used to analyze the results. We included 61 patients, but the final population consisted of 10 patients (7 men and 3 women) because of sequential analysis. Comparison of the test results obtained at two and six months after treatment initiation with those obtained at baseline revealed that HFA at two months and PTA at six months detected hearing threshold shifts consistent with ototoxicity. However, DPOAE testing did not detect such shifts. The statistical method used in this study makes it possible to conclude that, over the six-month period, amikacin-associated hearing threshold shifts were detected by HFA and PTA, and that DPOAE testing was not efficient in detecting such shifts.
Flight test results of the strapdown ring laser gyro tetrad inertial navigation system
NASA Technical Reports Server (NTRS)
Carestia, R. A.; Hruby, R. J.; Bjorkman, W. S.
1983-01-01
A helicopter flight test program undertaken to evaluate the performance of Tetrad (a strap down, laser gyro, inertial navigation system) is described. The results of 34 flights show a mean final navigational velocity error of 5.06 knots, with a standard deviation of 3.84 knots; a corresponding mean final position error of 2.66 n. mi., with a standard deviation of 1.48 n. mi.; and a modeled mean position error growth rate for the 34 tests of 1.96 knots, with a standard deviation of 1.09 knots. No laser gyro or accelerometer failures were detected during the flight tests. Off line parity residual studies used simulated failures with the prerecorded flight test and laboratory test data. The airborne Tetrad system's failure--detection logic, exercised during the tests, successfully demonstrated the detection of simulated ""hard'' failures and the system's ability to continue successfully to navigate by removing the simulated faulted sensor from the computations. Tetrad's four ring laser gyros provided reliable and accurate angular rate sensing during the 4 yr of the test program, and no sensor failures were detected during the evaluation of free inertial navigation performance.
2014-01-01
Background Cases of Mycobacterium bovis infection South American camelids have been increasing in Great Britain. Current antemortem immunological tests have some limitations. Cases at post mortem examination frequently show extensive pathology. The feasibility of detecting Mycobacterium bovis DNA in clinical samples was investigated. Findings A sensitive extraction methodology was developed and used on nasal swabs and faeces taken post-mortem to assess the potential for a PCR test to detect Mycobacterium bovis in clinical samples. The gross pathology of the studied South American camelids was scored and a significantly greater proportion of South American camelids with more severe pathology were positive in both the nasal swab and faecal PCR tests. A combination of the nasal swab and faecal PCR tests detected 63.9% of all the South American camelids with pathology that were tested. Conclusions The results suggest that antemortem diagnosis of Mycobacterium bovis in South American camelids may be possible using a PCR test on clinical samples, however more work is required to determine sensitivity and specificity, and the practicalities of applying the test in the field. PMID:24507471
Castle, Philip E.; Eaton, Barbara; Reid, Jennifer; Dockter, Janel
2015-01-01
Few studies have compared the cobas HPV test to the Aptima HPV assay (AHPV) and the Aptima HPV 16 18/45 genotype assay (AHPV GT) for high-risk human papillomavirus (hrHPV) detection, clinical performance in detecting cervical intraepithelial neoplasia grade 2 (CIN2) or more severe (CIN2+) diagnoses, and risk stratification by partial HPV genotyping. The cobas HPV test is a DNA test that separately and concurrently detects HPV16, HPV18, and a pool of 12 other hrHPV types. AHPV is an RNA test for a pool of 14 hrHPV genotypes, and AHPV GT is an RNA test run on AHPV-positive results to detect HPV16 separately from HPV18 and HPV45, which are detected together. In a population of patients (n = 988) referred for colposcopy because of a cervical Pap cytology result of atypical squamous cells of undetermined significance (ASC-US), a cervical scrape specimen was taken, placed into a ThinPrep Pap test vial containing PreservCyt liquid cytology medium, and tested in a blinded fashion with cobas and AHPV and with AHPV GT for AHPV-positive results. The final diagnoses were based on a consensus panel review of the biopsy specimen histology. AHPV and cobas were equally sensitive for CIN2+ diagnoses (89.4% each; P = 1.000), and AHPV was more specific than cobas (63.1% versus 59.3%; P ≤ 0.001). The percent total agreement, percent positive agreement, and kappa value were 90.9%, 81.1%, and 0.815, respectively. Risk stratification using partial HPV genotyping was similar for the two assays. AHPV and AHPV GT had similar sensitivity and risk stratification to cobas HPV, but they were more specific than cobas HPV. PMID:25653409
Detection of Methicillin-Resistant Coagulase-Negative Staphylococci by the Vitek 2 System
Johnson, Kristen N.; Andreacchio, Kathleen
2014-01-01
The accurate performance of the Vitek 2 GP67 card for detecting methicillin-resistant coagulase-negative staphylococci (CoNS) is not known. We prospectively determined the ability of the Vitek 2 GP67 card to accurately detect methicillin-resistant CoNS, with mecA PCR results used as the gold standard for a 4-month period in 2012. Included in the study were 240 consecutively collected nonduplicate CoNS isolates. Cefoxitin susceptibility by disk diffusion testing was determined for all isolates. We found that the three tested systems, Vitek 2 oxacillin and cefoxitin testing and cefoxitin disk susceptibility testing, lacked specificity and, in some cases, sensitivity for detecting methicillin resistance. The Vitek 2 oxacillin and cefoxitin tests had very major error rates of 4% and 8%, respectively, and major error rates of 38% and 26%, respectively. Disk cefoxitin testing gave the best performance, with very major and major error rates of 2% and 24%, respectively. The test performances were species dependent, with the greatest errors found for Staphylococcus saprophyticus. While the 2014 CLSI guidelines recommend reporting isolates that test resistant by the oxacillin MIC or cefoxitin disk test as oxacillin resistant, following such guidelines produces erroneous results, depending on the test method and bacterial species tested. Vitek 2 cefoxitin testing is not an adequate substitute for cefoxitin disk testing. For critical-source isolates, mecA PCR, rather than Vitek 2 or cefoxitin disk testing, is required for optimal antimicrobial therapy. PMID:24951799
Detection of CMOS bridging faults using minimal stuck-at fault test sets
NASA Technical Reports Server (NTRS)
Ijaz, Nabeel; Frenzel, James F.
1993-01-01
The performance of minimal stuck-at fault test sets at detecting bridging faults are evaluated. New functional models of circuit primitives are presented which allow accurate representation of bridging faults under switch-level simulation. The effectiveness of the patterns is evaluated using both voltage and current testing.
Detecting Item Drift in Large-Scale Testing
ERIC Educational Resources Information Center
Guo, Hongwen; Robin, Frederic; Dorans, Neil
2017-01-01
The early detection of item drift is an important issue for frequently administered testing programs because items are reused over time. Unfortunately, operational data tend to be very sparse and do not lend themselves to frequent monitoring analyses, particularly for on-demand testing. Building on existing residual analyses, the authors propose…
Bird, Patrick; Fisher, Kiel; Boyle, Megan; Huffman, Travis; Benzinger, M Joseph; Bedinghaus, Paige; Flannery, Jonathan; Crowley, Erin; Agin, James; Goins, David; Benesh, DeAnn; David, John
2013-01-01
The 3M Molecular Detection Assay (MDA) Salmonella is used with the 3M Molecular Detection System for the detection of Salmonella spp. in food, food-related, and environmental samples after enrichment. The assay utilizes loop-mediated isothermal amplification to rapidly amplify Salmonella target DNA with high specificity and sensitivity, combined with bioluminescence to detect the amplification. The 3M MDA Salmonella method was compared using an unpaired study design in a multilaboratory collaborative study to the U.S. Department of Agriculture/Food Safety and Inspection Service-Microbiology Laboratory Guidebook (USDA/FSIS-MLG 4.05), Isolation and Identification of Salmonella from Meat, Poultry, Pasteurized Egg and Catfish Products for raw ground beef and the U.S. Food and Drug Administration/Bacteriological Analytical Manual (FDA/BAM) Chapter 5 Salmonella reference method for wet dog food following the current AOAC guidelines. A total of 20 laboratories participated. For the 3M MDA Salmonella method, raw ground beef was analyzed using 25 g test portions, and wet dog food was analyzed using 375 g test portions. For the reference methods, 25 g test portions of each matrix were analyzed. Each matrix was artificially contaminated with Salmonella at three inoculation levels: an uninoculated control level (0 CFU/test portion), a low inoculum level (0.2-2 CFU/test portion), and a high inoculum level (2-5 CFU/test portion). In this study, 1512 unpaired replicate samples were analyzed. Statistical analysis was conducted according to the probability of detection (POD). For the low-level raw ground beef test portions, the following dLPOD (difference between the POD of the reference and candidate method) values with 95% confidence intervals were obtained: -0.01 (-0.14, +0.12). For the low-level wet dog food test portions, the following dLPOD with 95% confidence intervals were obtained: -0.04 (-0.16, +0.09). No significant differences were observed in the number of positive samples detected by the 3M MDA Salmonella method versus either the USDA/FSIS-MLG or FDA/BAM methods.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bartholomew, Rachel A.; Ozanich, Richard M.; Arce, Jennifer S.
2017-02-01
The goal of this testing was to evaluate the ability of currently available commercial off-the-shelf (COTS) biological indicator tests and immunoassays to detect Bacillus anthracis (Ba) spores and ricin. In general, immunoassays provide more specific identification of biological threats as compared to indicator tests [3]. Many of these detection products are widely used by first responders and other end users. In most cases, performance data for these instruments are supplied directly from the manufacturer, but have not been verified by an external, independent assessment [1]. Our test plan modules included assessments of inclusivity (ability to generate true positive results), commonlymore » encountered hoax powders (which can cause potential interferences or false positives), and estimation of limit of detection (LOD) (sensitivity) testing.« less
How good are indirect tests at detecting recombination in human mtDNA?
White, Daniel James; Bryant, David; Gemmell, Neil John
2013-07-08
Empirical proof of human mitochondrial DNA (mtDNA) recombination in somatic tissues was obtained in 2004; however, a lack of irrefutable evidence exists for recombination in human mtDNA at the population level. Our inability to demonstrate convincingly a signal of recombination in population data sets of human mtDNA sequence may be due, in part, to the ineffectiveness of current indirect tests. Previously, we tested some well-established indirect tests of recombination (linkage disequilibrium vs. distance using D' and r(2), Homoplasy Test, Pairwise Homoplasy Index, Neighborhood Similarity Score, and Max χ(2)) on sequence data derived from the only empirically confirmed case of human mtDNA recombination thus far and demonstrated that some methods were unable to detect recombination. Here, we assess the performance of these six well-established tests and explore what characteristics specific to human mtDNA sequence may affect their efficacy by simulating sequence under various parameters with levels of recombination (ρ) that vary around an empirically derived estimate for human mtDNA (population parameter ρ = 5.492). No test performed infallibly under any of our scenarios, and error rates varied across tests, whereas detection rates increased substantially with ρ values > 5.492. Under a model of evolution that incorporates parameters specific to human mtDNA, including rate heterogeneity, population expansion, and ρ = 5.492, successful detection rates are limited to a range of 7-70% across tests with an acceptable level of false-positive results: the neighborhood similarity score incompatibility test performed best overall under these parameters. Population growth seems to have the greatest impact on recombination detection probabilities across all models tested, likely due to its impact on sequence diversity. The implications of our findings on our current understanding of mtDNA recombination in humans are discussed.
How Good Are Indirect Tests at Detecting Recombination in Human mtDNA?
White, Daniel James; Bryant, David; Gemmell, Neil John
2013-01-01
Empirical proof of human mitochondrial DNA (mtDNA) recombination in somatic tissues was obtained in 2004; however, a lack of irrefutable evidence exists for recombination in human mtDNA at the population level. Our inability to demonstrate convincingly a signal of recombination in population data sets of human mtDNA sequence may be due, in part, to the ineffectiveness of current indirect tests. Previously, we tested some well-established indirect tests of recombination (linkage disequilibrium vs. distance using D′ and r2, Homoplasy Test, Pairwise Homoplasy Index, Neighborhood Similarity Score, and Max χ2) on sequence data derived from the only empirically confirmed case of human mtDNA recombination thus far and demonstrated that some methods were unable to detect recombination. Here, we assess the performance of these six well-established tests and explore what characteristics specific to human mtDNA sequence may affect their efficacy by simulating sequence under various parameters with levels of recombination (ρ) that vary around an empirically derived estimate for human mtDNA (population parameter ρ = 5.492). No test performed infallibly under any of our scenarios, and error rates varied across tests, whereas detection rates increased substantially with ρ values > 5.492. Under a model of evolution that incorporates parameters specific to human mtDNA, including rate heterogeneity, population expansion, and ρ = 5.492, successful detection rates are limited to a range of 7−70% across tests with an acceptable level of false-positive results: the neighborhood similarity score incompatibility test performed best overall under these parameters. Population growth seems to have the greatest impact on recombination detection probabilities across all models tested, likely due to its impact on sequence diversity. The implications of our findings on our current understanding of mtDNA recombination in humans are discussed. PMID:23665874
Rapid antigen detection test for respiratory syncytial virus diagnosis as a diagnostic tool.
Mesquita, Flávio da Silva; Oliveira, Danielle Bruna Leal de; Crema, Daniela; Pinez, Célia Miranda Nunes; Colmanetti, Thaís Cristina; Thomazelli, Luciano Matsumia; Gilio, Alfredo Elias; Vieira, Sandra Elisabeth; Martinez, Marina Baquerizo; Botosso, Viviane Fongaro; Durigon, Edison Luiz
The aim of this study was to evaluate the QuickVue ® RSV Test Kit (QUIDEL Corp, CA, USA) as a screening tool for respiratory syncytial virus in children with acute respiratory disease in comparison with the indirect immunofluorescence assay as gold standard. In Brazil, rapid antigen detection tests for respiratory syncytial virus are not routinely utilized as a diagnostic tool, except for the diagnosis of dengue and influenza. The authors retrospectively analyzed 486 nasopharyngeal aspirate samples from children under age 5 with acute respiratory infection, between December 2013 and August 2014, the samples were analyzed by indirect immunofluorescence assay and QuickVue ® RSV Test kit. Samples with discordant results were analyzed by real time PCR and nucleotide sequencing. From 313 positive samples by immunofluorescence assays, 282 (90%) were also positive by the rapid antigen detection test, two were positive only by rapid antigen detection test, 33 were positive only by immunofluorescence assays, and 171 were positive by both methods. The 35 samples with discordant results were analyzed by real time PCR; the two samples positive only by rapid antigen detection test and the five positive only by immunofluorescence assays were also positive by real time PCR. There was no relation between the negativity by QuickVue ® RSV Test and viral load or specific strain. The QuickVue ® RSV Test showed sensitivity of 90%, specificity of 98.8%, predictive positive value of 99.3%, and negative predictive value of 94.6%, with accuracy of 93.2% and agreement κ index of 0.85 in comparison to immunofluorescence assay. This study demonstrated that the QuickVue ® RSV Test Kit can be effective in early detection of Respiratory syncytial virus in nasopharyngeal aspirate and is reliable for use as a diagnostic tool in pediatrics. Copyright © 2016 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.
van Rijn, Piet A; Heutink, René G; Boonstra, Jan; Kramps, Hans A; van Gennip, René G P
2012-05-01
A real-time reverse transcription polymerase chain reaction assay (PCR test) based on genome segment 10 of Bluetongue virus (BTV) was developed. The PCR test consists of robotized viral RNA isolation from blood samples and an all-in-one method including initial denaturation of genomic double-stranded RNA, reverse transcription polymerase chain reaction (RT-PCR), and real-time detection and analysis. Reference strains of the 24 recognized BTV serotypes, isolates from different years, and geographic origins were detected. Other orbiviruses such as African horse sickness virus, Epizootic hemorrhagic disease virus, and Equine encephalosis virus were not detected. Experimentally infected animals were PCR positive from 2 days postinoculation, which was earlier than fever, other clinical signs, or seroconversion. The diagnostic sensitivity and specificity were very close to or even 100%. The PCR test played a key role in the detection of BTV serotype 8 in August 2006 in The Netherlands. The outbreak in a completely naive ruminant population allowed for further evaluation of the PCR test with field samples. In 2006, the correlation between enzyme-linked immunosorbent assay and PCR results was estimated to be 95%. In the following years, the PCR test was used for diagnosis of diseased animals, for testing of healthy animals for trade purposes, and for detection of BTV RNA in different species of the insect vector, Culicoides. In the autumn of 2008, BTV serotype 6 unexpectedly emerged in northwest Europe and was also detected with the PCR test developed in the current study. The performance in routine use over 5 years has been recorded and evaluated.
Cantwell, H; O'Keeffe, M
2006-02-01
The Premi Test, a test kit designed for the rapid screening of antimicrobial residues in meat, fish and eggs, was evaluated and compared with the (modified) One-Plate Test, an agar diffusion assay. The performance characteristics described for qualitative, screening methods in Commission Decision 2002/657/EC were used for the evaluation. The Premi Test was found to detect a range of antimicrobials to MRL levels in kidney fluid but to have poorer sensitivity for some antimicrobials such as tetracyclines, sulphonamides, flumequine and streptomycin. The test was found not to be sensitive for the banned antimicrobial chloramphenicol. The One-Plate Test was found to detect most tetracyclines and flumequine to MRL levels but to be less sensitive than the Premi Test for most of the other classes of antimicrobials. Neither test alone provides a comprehensive screening test for antimicrobial residues in kidney at MRL levels. However, the Premi Test is fast, easy to use and rugged and, in combination with other antimicrobial tests, may be used to provide a comprehensive screening system for antimicrobials in tissues.
Handheld hyperspectral imager for standoff detection of chemical and biological aerosols
NASA Astrophysics Data System (ADS)
Hinnrichs, Michele; Jensen, James O.; McAnally, Gerard
2004-08-01
Pacific Advanced Technology has developed a small hand held imaging spectrometer, Sherlock, for gas leak and aerosol detection and imaging. The system is based on a patented technique, (IMSS Image Multi-spectral Sensing), that uses diffractive optics and image processing algorithms to detect spectral information about objects in the scene of the camera. This cameras technology has been tested at Dugway Proving Ground and Dstl Porton Down facilities looking at Chemical and Biological agent simulants. In addition to Chemical and Biological detection, the camera has been used for environmental monitoring of green house gases and is currently undergoing extensive laboratory and field testing by the Gas Technology Institute, British Petroleum and Shell Oil for applications for gas leak detection and repair. In this paper we will present some of the results from the data collection at the TRE test at Dugway Proving Ground during the summer of 2002 and laboratory testing at the Dstl facility at Porton Down in the UK in the fall of 2002.
Detection of fatigue cracks by nondestructive testing methods
NASA Technical Reports Server (NTRS)
Anderson, R. T.; Delacy, T. J.; Stewart, R. C.
1973-01-01
The effectiveness was assessed of various NDT methods to detect small tight cracks by randomly introducing fatigue cracks into aluminum sheets. The study included optimizing NDT methods calibrating NDT equipment with fatigue cracked standards, and evaluating a number of cracked specimens by the optimized NDT methods. The evaluations were conducted by highly trained personnel, provided with detailed procedures, in order to minimize the effects of human variability. These personnel performed the NDT on the test specimens without knowledge of the flaw locations and reported on the flaws detected. The performance of these tests was measured by comparing the flaws detected against the flaws present. The principal NDT methods utilized were radiographic, ultrasonic, penetrant, and eddy current. Holographic interferometry, acoustic emission monitoring, and replication methods were also applied on a reduced number of specimens. Generally, the best performance was shown by eddy current, ultrasonic, penetrant and holographic tests. Etching provided no measurable improvement, while proof loading improved flaw detectability. Data are shown that quantify the performances of the NDT methods applied.
Intelligent transient transitions detection of LRE test bed
NASA Astrophysics Data System (ADS)
Zhu, Fengyu; Shen, Zhengguang; Wang, Qi
2013-01-01
Health Monitoring Systems is an implementation of monitoring strategies for complex systems whereby avoiding catastrophic failure, extending life and leading to improved asset management. A Health Monitoring Systems generally encompasses intelligence at many levels and sub-systems including sensors, actuators, devices, etc. In this paper, a smart sensor is studied, which is use to detect transient transitions of liquid-propellant rocket engines test bed. In consideration of dramatic changes of variable condition, wavelet decomposition is used to work real time in areas. Contrast to traditional Fourier transform method, the major advantage of adding wavelet analysis is the ability to detect transient transitions as well as obtaining the frequency content using a much smaller data set. Historically, transient transitions were only detected by offline analysis of the data. The methods proposed in this paper provide an opportunity to detect transient transitions automatically as well as many additional data anomalies, and provide improved data-correction and sensor health diagnostic abilities. The developed algorithms have been tested on actual rocket test data.
Measurement of fault latency in a digital avionic miniprocessor
NASA Technical Reports Server (NTRS)
Mcgough, J. G.; Swern, F. L.
1981-01-01
The results of fault injection experiments utilizing a gate-level emulation of the central processor unit of the Bendix BDX-930 digital computer are presented. The failure detection coverage of comparison-monitoring and a typical avionics CPU self-test program was determined. The specific tasks and experiments included: (1) inject randomly selected gate-level and pin-level faults and emulate six software programs using comparison-monitoring to detect the faults; (2) based upon the derived empirical data develop and validate a model of fault latency that will forecast a software program's detecting ability; (3) given a typical avionics self-test program, inject randomly selected faults at both the gate-level and pin-level and determine the proportion of faults detected; (4) determine why faults were undetected; (5) recommend how the emulation can be extended to multiprocessor systems such as SIFT; and (6) determine the proportion of faults detected by a uniprocessor BIT (built-in-test) irrespective of self-test.
Scintillating anticoincidence detection elements design and tests with muons and protons
NASA Astrophysics Data System (ADS)
Gilliot, M.; Chabaud, J.; Baronick, J. P.; Colonges, S.; Laurent, P.
2010-09-01
Design, construction and tests of anticoincidence detection elements are presented. Initially planned to be used as active shielding parts of the anticoincidence detector of the Simbol-X mission, they are aimed to detect cosmic protons and provide veto signal against charged-particle background induced on imaging detectors. The sample is made of a scintillator plate into which grooves are machined and waveshifting fibers glued. The fibers are connected to multianode photomultiplier (PM) tubes. The tubes characteristics have been evaluated for this application. The device has been tested with atmospheric muons that deposit similar energy to that of cosmic protons thanks to a specially designed muon telescope also described in this paper. Tests have also been performed with protons of a tandem accelerator beam line. The response is on average above 10 photoelectrons, which is not complicated to detect, which allows very good detection efficiency as well as very good ability to reject noise. In addition many evolution and performance improvements appear possible.
EU-approved rapid tests might underestimate bovine spongiform encephalopathy infection in goats.
Meloni, Daniela; Bozzetta, Elena; Langeveld, Jan P M; Groschup, Martin H; Goldmann, Wilfred; Andrèoletti, Olivier; Lantier, Isabelle; Van Keulen, Lucien; Bossers, Alex; Pitardi, Danilo; Nonno, Romolo; Sklaviadis, Theodoros; Ingravalle, Francesco; Peletto, Simone; Colussi, Silvia; Acutis, Pier Luigi
2017-03-01
We report the diagnostic sensitivity of 3 EU-approved rapid tests (ELISAs; 1 from IDEXX and 2 from Bio-Rad) for the detection of transmissible spongiform encephalopathy diseases in goats. Ninety-eight goat brainstem samples were tested. All the rapid tests had 100% specificity and ≥80% sensitivity, with the IDEXX test significantly more sensitive than the 2 Bio-Rad tests. All tests detected 100% of samples from goats with clinical scrapie, but missed 8% (IDEXX) to 33% (Bio-Rad SG) of samples from preclinical goats. Importantly, only IDEXX picked up all samples from clinical bovine spongiform encephalopathy (BSE)-infected goats, whereas the other 2 rapid tests missed 15% (Bio-Rad SG) to 25% (Bio-Rad SAP). These results show that a fraction of preclinical scrapie infections are likely missed by EU surveillance, with sensitivity of detection strongly dependent on the choice of the rapid test. Moreover, a significant proportion of clinical BSE infections are underestimated by using either Bio-Rad test. Assuming that the same sensitivity on preclinical goats would also occur in BSE-infected goats, our data suggest that IDEXX is likely the most sensitive test for detecting preclinical field cases of BSE infection in goats, although with an 8% failure rate. These results raise some concerns about the reliability of current EU surveillance figures on BSE infection in goats.
Dynamic assertion testing of flight control software
NASA Technical Reports Server (NTRS)
Andrews, D. M.; Mahmood, A.; Mccluskey, E. J.
1985-01-01
An experiment in using assertions to dynamically test fault tolerant flight software is described. The experiment showed that 87% of typical errors introduced into the program would be detected by assertions. Detailed analysis of the test data showed that the number of assertions needed to detect those errors could be reduced to a minimal set. The analysis also revealed that the most effective assertions tested program parameters that provided greater indirect (collateral) testing of other parameters.
Detecting Growth Shape Misspecifications in Latent Growth Models: An Evaluation of Fit Indexes
ERIC Educational Resources Information Center
Leite, Walter L.; Stapleton, Laura M.
2011-01-01
In this study, the authors compared the likelihood ratio test and fit indexes for detection of misspecifications of growth shape in latent growth models through a simulation study and a graphical analysis. They found that the likelihood ratio test, MFI, and root mean square error of approximation performed best for detecting model misspecification…
10 CFR 36.59 - Detection of leaking sources.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 1 2010-01-01 2010-01-01 false Detection of leaking sources. 36.59 Section 36.59 Energy... Irradiators § 36.59 Detection of leaking sources. (a) Each dry-source-storage sealed source must be tested for leakage at intervals not to exceed 6 months using a leak test kit or method approved by the Commission or...
Weld leaks rapidly and safely detected
NASA Technical Reports Server (NTRS)
1965-01-01
Test method detects leaks that occur during hydrostatic pressure testing of welded joints in metal tanks. A strip of aluminum foil and a strip of water-soluble paper are placed over the weld. A voltage applied between the tank wall and the foil strip is monitored to detect a decrease in ohmic resistance caused by water leakage into the paper layer.
Testing Signal-Detection Models of Yes/No and Two-Alternative Forced-Choice Recognition Memory
ERIC Educational Resources Information Center
Jang, Yoonhee; Wixted, John T.; Huber, David E.
2009-01-01
The current study compared 3 models of recognition memory in their ability to generalize across yes/no and 2-alternative forced-choice (2AFC) testing. The unequal-variance signal-detection model assumes a continuous memory strength process. The dual-process signal-detection model adds a thresholdlike recollection process to a continuous…
The Application of Surface Potential Test on Hand-making Insulation for Generator Stator End-winding
NASA Astrophysics Data System (ADS)
Lu, Zhu-mao; Liu, Qing; Wang, Tian-zheng; Bai, Lu; Li, Yan-peng
2017-05-01
This paper presents the advantage of surface potential test on hand-making insulation for generator stator end-winding insulation detection, compared with DC or AC withstand voltage test, also details the test principle, connection method and test notes. And through the case, surface potential test on hand-making insulation proved effective for insulation quality detection after generator stator end-winding maintenance, and the experimental data is useful and reliable for the electrical equipment operation and maintenance in the power plant.
Detection and avoidance of errors in computer software
NASA Technical Reports Server (NTRS)
Kinsler, Les
1989-01-01
The acceptance test errors of a computer software project to determine if the errors could be detected or avoided in earlier phases of development. GROAGSS (Gamma Ray Observatory Attitude Ground Support System) was selected as the software project to be examined. The development of the software followed the standard Flight Dynamics Software Development methods. GROAGSS was developed between August 1985 and April 1989. The project is approximately 250,000 lines of code of which approximately 43,000 lines are reused from previous projects. GROAGSS had a total of 1715 Change Report Forms (CRFs) submitted during the entire development and testing. These changes contained 936 errors. Of these 936 errors, 374 were found during the acceptance testing. These acceptance test errors were first categorized into methods of avoidance including: more clearly written requirements; detail review; code reading; structural unit testing; and functional system integration testing. The errors were later broken down in terms of effort to detect and correct, class of error, and probability that the prescribed detection method would be successful. These determinations were based on Software Engineering Laboratory (SEL) documents and interviews with the project programmers. A summary of the results of the categorizations is presented. The number of programming errors at the beginning of acceptance testing can be significantly reduced. The results of the existing development methodology are examined for ways of improvements. A basis is provided for the definition is a new development/testing paradigm. Monitoring of the new scheme will objectively determine its effectiveness on avoiding and detecting errors.
Syngelaki, Argyro; Pergament, Eugene; Homfray, Tessa; Akolekar, Ranjit; Nicolaides, Kypros H
2014-01-01
To estimate the proportion of other chromosomal abnormalities that could be missed if combined testing was replaced by cell-free (cf) DNA testing as the method of screening for trisomies 21, 18 and 13. The prevalence of trisomies 21, 18 or 13, sex chromosome aneuploidies, triploidy and other chromosomal abnormalities was examined in pregnancies undergoing first-trimester combined screening and chorionic villus sampling (CVS). In 1,831 clinically significant chromosomal abnormalities in pregnancies with combined risk for trisomies 21, 18 and 13≥1:100, the contribution of trisomies 21, 18 or 13, sex chromosome aneuploidies, triploidy and other chromosomal abnormalities at high risk of adverse outcome was 82.9, 8.2, 3.9 and 5.0%, respectively. Combined screening followed by CVS for risk≥1:10 and cfDNA testing for risk 1:11-1:2,500 could detect 97% of trisomy 21 and 98% of trisomies 18 and 13. Additionally, 86% of monosomy X, half of 47,XXY, 47,XYY or 47,XXX, half of other chromosomal abnormalities and one third of triploidies, which are currently detected by combined screening and CVS for risk≥1:100, could be detected. Screening by cfDNA testing, contingent on results of combined testing, improves detection of trisomies, but misses a few of the other chromosomal abnormalities detected by screening with the combined test. © 2014 S. Karger AG, Basel.
Multiratio fusion change detection with adaptive thresholding
NASA Astrophysics Data System (ADS)
Hytla, Patrick C.; Balster, Eric J.; Vasquez, Juan R.; Neuroth, Robert M.
2017-04-01
A ratio-based change detection method known as multiratio fusion (MRF) is proposed and tested. The MRF framework builds on other change detection components proposed in this work: dual ratio (DR) and multiratio (MR). The DR method involves two ratios coupled with adaptive thresholds to maximize detected changes and minimize false alarms. The use of two ratios is shown to outperform the single ratio case when the means of the image pairs are not equal. MR change detection builds on the DR method by including negative imagery to produce four total ratios with adaptive thresholds. Inclusion of negative imagery is shown to improve detection sensitivity and to boost detection performance in certain target and background cases. MRF further expands this concept by fusing together the ratio outputs using a routine in which detections must be verified by two or more ratios to be classified as a true changed pixel. The proposed method is tested with synthetically generated test imagery and real datasets with results compared to other methods found in the literature. DR is shown to significantly outperform the standard single ratio method. MRF produces excellent change detection results that exhibit up to a 22% performance improvement over other methods from the literature at low false-alarm rates.
Ochodo, Eleanor A; Gopalakrishna, Gowri; Spek, Bea; Reitsma, Johannes B; van Lieshout, Lisette; Polman, Katja; Lamberton, Poppy; Bossuyt, Patrick Mm; Leeflang, Mariska Mg
2015-01-01
Background Point-of-care (POC) tests for diagnosing schistosomiasis include tests based on circulating antigen detection and urine reagent strip tests. If they had sufficient diagnostic accuracy they could replace conventional microscopy as they provide a quicker answer and are easier to use. Objectives To summarise the diagnostic accuracy of: a) urine reagent strip tests in detecting active Schistosoma haematobium infection, with microscopy as the reference standard; and b) circulating antigen tests for detecting active Schistosoma infection in geographical regions endemic for Schistosoma mansoni or S. haematobium or both, with microscopy as the reference standard. Search methods We searched the electronic databases MEDLINE, EMBASE, BIOSIS, MEDION, and Health Technology Assessment (HTA) without language restriction up to 30 June 2014. Selection criteria We included studies that used microscopy as the reference standard: for S. haematobium, microscopy of urine prepared by filtration, centrifugation, or sedimentation methods; and for S. mansoni, microscopy of stool by Kato-Katz thick smear. We included studies on participants residing in endemic areas only. Data collection and analysis Two review authors independently extracted data, assessed quality of the data using QUADAS-2, and performed meta-analysis where appropriate. Using the variability of test thresholds, we used the hierarchical summary receiver operating characteristic (HSROC) model for all eligible tests (except the circulating cathodic antigen (CCA) POC for S. mansoni, where the bivariate random-effects model was more appropriate). We investigated heterogeneity, and carried out indirect comparisons where data were sufficient. Results for sensitivity and specificity are presented as percentages with 95% confidence intervals (CI). Main results We included 90 studies; 88 from field settings in Africa. The median S. haematobium infection prevalence was 41% (range 1% to 89%) and 36% for S. mansoni (range 8% to 95%). Study design and conduct were poorly reported against current standards. Tests for S. haematobium Urine reagent test strips versus microscopy Compared to microscopy, the detection of microhaematuria on test strips had the highest sensitivity and specificity (sensitivity 75%, 95% CI 71% to 79%; specificity 87%, 95% CI 84% to 90%; 74 studies, 102,447 participants). For proteinuria, sensitivity was 61% and specificity was 82% (82,113 participants); and for leukocyturia, sensitivity was 58% and specificity 61% (1532 participants). However, the difference in overall test accuracy between the urine reagent strips for microhaematuria and proteinuria was not found to be different when we compared separate populations (P = 0.25), or when direct comparisons within the same individuals were performed (paired studies; P = 0.21). When tests were evaluated against the higher quality reference standard (when multiple samples were analysed), sensitivity was marginally lower for microhaematuria (71% vs 75%) and for proteinuria (49% vs 61%). The specificity of these tests was comparable. Antigen assay Compared to microscopy, the CCA test showed considerable heterogeneity; meta-analytic sensitivity estimate was 39%, 95% CI 6% to 73%; specificity 78%, 95% CI 55% to 100% (four studies, 901 participants). Tests for S. mansoni Compared to microscopy, the CCA test meta-analytic estimates for detecting S. mansoni at a single threshold of trace positive were: sensitivity 89% (95% CI 86% to 92%); and specificity 55% (95% CI 46% to 65%; 15 studies, 6091 participants) Against a higher quality reference standard, the sensitivity results were comparable (89% vs 88%) but specificity was higher (66% vs 55%). For the CAA test, sensitivity ranged from 47% to 94%, and specificity from 8% to 100% (4 studies, 1583 participants). Authors' conclusions Among the evaluated tests for S. haematobium infection, microhaematuria correctly detected the largest proportions of infections and non-infections identified by microscopy. The CCA POC test for S. mansoni detects a very large proportion of infections identified by microscopy, but it misclassifies a large proportion of microscopy negatives as positives in endemic areas with a moderate to high prevalence of infection, possibly because the test is potentially more sensitive than microscopy. Plain Language Summary How well do point-of-care tests detect Schistosoma infections in people living inendemic areas? Schistosomiasis, also known as bilharzia, is a parasitic disease common in the tropical and subtropics. Point-of-care tests and urine reagent strip tests are quicker and easier to use than microscopy. We estimate how well these point-of-care tests are able to detect schistosomiasis infections compared with microscopy. We searched for studies published in any language up to 30 June 2014, and we considered the study’s risk of providing biased results. What do the results say? We included 90 studies involving almost 200,000 people, with 88 of these studies carried out in Africa in field settings. Study design and conduct were poorly reported against current expectations. Based on our statistical model, we found: • Among the urine strips for detecting urinary schistosomiasis, the strips for detecting blood were better than those detecting protein or white cells (sensitivity and specificity for blood 75% and 87%; for protein 61% and 82%; and for white cells 58% and 61%, respectively). • For urinary schistosomiasis, the parasite antigen test performance was worse (sensitivity, 39% and specificity, 78%) than urine strips for detecting blood. • For intestinal schistosomiasis, the parasite antigen urine test, detected many infections identified by microscopy but wrongly labelled many uninfected people as sick (sensitivity, 89% and specificity, 55%). What are the consequences of using these tests? If we take 1000 people, of which 410 have urinary schistosomiasis on microscopy testing, then using the strip detecting blood in the urine would misclassify 77 uninfected people as infected, and thus may receive unnecessary treatment; and it would wrongly classify 102 infected people as uninfected, who thus may not receive treatment. If we take 1000 people, of which 360 have intestinal schistosomiasis on microscopy testing, then the antigen test would misclassify 288 uninfected people as infected. These people may be given unnecessary treatment. This test also would wrongly classify 40 infected people as uninfected who thus may not receive treatment. Conclusion of review For urinary schistosomiasis, the urine strip for detecting blood leads to some infected people being missed and some non-infected people being diagnosed with the condition, but is better than the protein or white cell tests. The parasite antigen test is not accurate. For intestinal schistosomiasis, the parasite antigen urine test can wrongly classify many uninfected people as infected. PMID:25758180
Detection of Bacteria Using Inkjet-Printed Enzymatic Test Strips
2015-01-01
Low-cost diagnostics for drinking water contamination have the potential to save millions of lives. We report a method that uses inkjet printing to copattern an enzyme–nanoparticle sensor and substrate on a paper-based test strip for rapid detection of bacteria. A colorimetric response is generated on the paper substrate that allows visual detection of contamination without the need for expensive instrumentation. These strips demonstrate a viable nanomanufacturing strategy for low-cost bacterial detection. PMID:25318086
Almeida, Jamie L.; Wang, Lili; Morrow, Jayne B.; Cole, Kenneth D.
2006-01-01
Bacillus anthracis spores have been used as biological weapons and the possibility of their further use requires surveillance systems that can accurately and reliably detect their presence in the environment. These systems must collect samples from a variety of matrices, process the samples, and detect the spores. The processing of the sample may include removal of inhibitors, concentration of the target, and extraction of the target in a form suitable for detection. Suitable reference materials will allow the testing of each of these steps to determine the sensitivity and specificity of the detection systems. The development of uniform and well-characterized reference materials will allow the comparison of different devices and technologies as well as assure the continued performance of detection systems. This paper discusses the special requirements of reference materials for Bacillus anthracis spores that could be used for testing detection systems. The detection of Bacillus anthracis spores is based on recognition of specific characteristics (markers) on either the spore surface or in the nucleic acids (DNA). We have reviewed the specific markers and their relevance to characterization of reference materials. We have also included the approach for the characterization of candidate reference materials that we are developing at the NIST laboratories. Additional applications of spore reference materials would include testing sporicidal treatments, techniques for sampling the environment, and remediation of spore-contaminated environments. PMID:27274929
A robust hypothesis test for the sensitive detection of constant speed radiation moving sources
NASA Astrophysics Data System (ADS)
Dumazert, Jonathan; Coulon, Romain; Kondrasovs, Vladimir; Boudergui, Karim; Moline, Yoann; Sannié, Guillaume; Gameiro, Jordan; Normand, Stéphane; Méchin, Laurence
2015-09-01
Radiation Portal Monitors are deployed in linear networks to detect radiological material in motion. As a complement to single and multichannel detection algorithms, inefficient under too low signal-to-noise ratios, temporal correlation algorithms have been introduced. Test hypothesis methods based on empirically estimated mean and variance of the signals delivered by the different channels have shown significant gain in terms of a tradeoff between detection sensitivity and false alarm probability. This paper discloses the concept of a new hypothesis test for temporal correlation detection methods, taking advantage of the Poisson nature of the registered counting signals, and establishes a benchmark between this test and its empirical counterpart. The simulation study validates that in the four relevant configurations of a pedestrian source carrier under respectively high and low count rate radioactive backgrounds, and a vehicle source carrier under the same respectively high and low count rate radioactive backgrounds, the newly introduced hypothesis test ensures a significantly improved compromise between sensitivity and false alarm. It also guarantees that the optimal coverage factor for this compromise remains stable regardless of signal-to-noise ratio variations between 2 and 0.8, therefore allowing the final user to parametrize the test with the sole prior knowledge of background amplitude.
NASA Astrophysics Data System (ADS)
Wang, Wenbo; Feng, Shangyuan; Tai, Isabella T.; Chen, Guannan; Chen, Rong; Zeng, Haishan
2016-03-01
Colorectal cancer (CRC) is the third most common type of cancer and forth leading cause of cancer-related death. Early diagnosis is the key to long-term patient survival. Programmatic screening for the general population has shown to be cost-effective in reducing the incidence and mortality from CRC. Current CRC screening strategy relies on a broad range of test techniques such as fecal based tests and endoscopic exams. Occult blood tests like fecal immunochemical test is a cost effective way to detect CRC but have limited diagnostic values in detecting adenomatous polyp, the most treatable precursor to CRC. In the present work, we proposed the use of surface enhanced Raman spectroscopy (SERS) with silver nanoparticles as substrate to analyze blood plasma for detecting both CRC and adenomatous polyps. Blood plasma samples collected from healthy subjects and patients diagnosed with adenomas and CRC were prepared with nanoparticles and measured using a real-time fiber optic probe based Raman system. The collected SERS spectra are analyzed with partial least squares-discriminant analysis. Classification of normal versus CRC plus adenomatous polyps achieved diagnostic sensitivity of 86.4% and specificity of 80%. This exploratory study suggests that blood plasma SERS analysis has potential to become a screening test for detecting both CRC and adenomas.
Laser diode arrays for naval reconnaissance
NASA Astrophysics Data System (ADS)
Holloway, John H., Jr.; Crosby, Frank J.; Petee, Danny A.; Suiter, Harold R.; Witherspoon, Ned H.
2003-09-01
The Airborne Littoral Reconnaissance Technologies (ALRT) Project has demonstrated a nighttime operational minefield detection capability using commercial off-the-shelf high-power Laser Diode Arrays (LDAs). Historically, optical aerial detection of minefields has primarily been limited to daytime operations but LDAs promise compact and efficient lighting to allow for enhanced reconnaissance operations for future mine detection systems. When combined with high-resolution intensified imaging systems, LDAs can illuminate otherwise unseen areas. Future wavelength options will open the way for active multispectral imaging with LDAs. The Coastal Systems Station working for the Office of Naval Research on the ALRT project has designed, developed, integrated, and tested both prototype and commercial arrays from a Cessna airborne platform. Detailed test results show the ability to detect several targets of interest in a variety of background conditions. Initial testing of the prototype arrays, reported on last year, was completed and further investigations of the commercial versions were performed. Polarization-state detection studies were performed, and advantageous properties of the source-target-sensor geometry noted. Current project plans are to expand the field-of-view coverage for Naval exercises in the summer of 2003. This paper describes the test collection, data library products, array information, on-going test analysis results, and future planned testing of the LDAs.
Rasmussen, Mats; Damgaard, Rasmus; Buus, Peter; Mulhall, Brian; Guazzo, Dana Morton
2013-01-01
Part 1 of this three-part research series detailed the development and validation of a high-voltage leak detection test (HVLD, also known as an electrical conductivity and capacitance test) for verifying the container-closure integrity of a small-volume laminate plastic bag containing an aqueous solution formulation of the rapid-acting insulin analogue, insulin aspart (NovoRapid®/NovoLog®) by Novo Nordisk A/S, Bagsværd, Denmark. Leak detection capability was verified using positive controls each with a single laser-drilled hole in the bag film face. In this Part 2, HVLD leak detection capability was further explored in four separate studies. Study 1 investigated the ability of HVLD to detect weaknesses and/or gaps in the bag heat seal. Study 2 checked the HVLD detection of bag holes in packages stored 4 days at ambient conditions followed by 17 days at refrigeration. Study 3 examined HVLD test results for packages tested when cold. Study 4 compared HVLD test results as a function of bag plastic film lots. The final Part 3 of this series will report the impact of HVLD exposure on product visual appearance and chemical stability. In Part 1 of this three-part series, a leak test method based on electrical conductivity and capacitance, also called high-voltage leak detection (HVLD), was used to find leaks in small plastic bags filled with a solution for injection of the rapid-acting insulin analogue, insulin aspart (NovoRapid®/NovoLog®) by Novo Nordisk A/S, Bagsværd, Denmark. In this Part 2, HVLD leak detection capability was further explored in four separate studies. Study 1 investigated the ability of HVLD to detect bag heat seal leaks. Study 2 checked HVLD's ability to detect bag holes after a total of 21 days at ambient plus refrigerated temperatures. Study 3 looked to see if HVLD results changed for packages tested when still cold. Study 4 compared HVLD results for multiple bag plastic film lots. The final Part 3 of this series will report any evidence of drug component degradation caused by HVLD exposure.
Zupańska, B; Maślanka, K; van Loghem, E
1982-11-01
13 anti-Rh sera were compared for their usefulness in the detection of Fc-receptor-bearing lymphocytes (EAhum test). IgG subclasses of anti-Rh antibodies were determined by the antiglobulin test with monospecific sera and by the detection of Gm allotypic markers in the haemagglutination inhibition test. Six sera with IgG1 + IgG3 or IgG1 + IgG2 + IgG3 antibodies and one with pure IgG3 antibodies were found to be useful, whereas six other sera with only IgG1 were unsuitable for the EAhum test. G3m markers were detected only on the anti-Rh antibodies which were capable of forming rosettes with lymphocytes. The data show that human peripheral lymphocytes possess Fc receptors for IgG3 immunoglobulins.
Becságh, Péter; Szakács, Orsolya
2014-10-01
During diagnostic workflow when detecting sequence alterations, sometimes it is important to design an algorithm that includes screening and direct tests in combination. Normally the use of direct test, which is mainly sequencing, is limited. There is an increased need for effective screening tests, with "closed tube" during the whole process and therefore decreasing the risk of PCR product contamination. The aim of this study was to design such a closed tube, detection probe based screening assay to detect different kind of sequence alterations in the exon 11 of the human c-kit gene region. Inside this region there are variable possible deletions and single nucleotide changes. During assay setup, more probe chemistry formats were screened and tested. After some optimization steps the taqman probe format was selected.
Sia, I G; Wilson, J A; Espy, M J; Paya, C V; Smith, T F
2000-02-01
Detection of cytomegalovirus (CMV) DNA in blood by PCR is a sensitive method for the detection of infection in patients posttransplantation. The test, however, has low specificity for the identification of overt CMV disease. Quantitative CMV PCR has been shown to overcome this shortcoming. The COBAS AMPLICOR CMV MONITOR test was evaluated by using consecutive serum and peripheral blood mononuclear cell (PBMN) samples from liver transplant patients. Twenty-five patients had CMV viremia (by shell vial cell culture assay) and/or tissue-invasive disease (by biopsy); 20 had no active infection. A total of 262 serum and 62 PBMN specimens were tested. Of 159 serum specimens from patients with overt CMV infection, the COBAS assay detected CMV DNA in 21 patients (sensitivity, 84%). Only 1 of 103 samples from patients with no evidence of active infection had detectable CMV DNA (341 copies/ml). By comparison of 62 matching serum and PBMN samples by the same assay, 12 PBMN samples were exclusively positive, whereas only 2 serum samples were exclusively positive (P < 0.05). At the time of clinical CMV infection, viral copy numbers were higher in PBMNs than serum from four of five patients. The COBAS AMPLICOR CMV MONITOR test is a sensitive and specific test for the quantitative detection of CMV DNA in blood. Clinical applications of the assay will require further validation with samples from a larger population of transplant patients.
Sia, Irene G.; Wilson, Jennie A.; Espy, Mark J.; Paya, Carlos V.; Smith, Thomas F.
2000-01-01
Detection of cytomegalovirus (CMV) DNA in blood by PCR is a sensitive method for the detection of infection in patients posttransplantation. The test, however, has low specificity for the identification of overt CMV disease. Quantitative CMV PCR has been shown to overcome this shortcoming. The COBAS AMPLICOR CMV MONITOR test was evaluated by using consecutive serum and peripheral blood mononuclear cell (PBMN) samples from liver transplant patients. Twenty-five patients had CMV viremia (by shell vial cell culture assay) and/or tissue-invasive disease (by biopsy); 20 had no active infection. A total of 262 serum and 62 PBMN specimens were tested. Of 159 serum specimens from patients with overt CMV infection, the COBAS assay detected CMV DNA in 21 patients (sensitivity, 84%). Only 1 of 103 samples from patients with no evidence of active infection had detectable CMV DNA (341 copies/ml). By comparison of 62 matching serum and PBMN samples by the same assay, 12 PBMN samples were exclusively positive, whereas only 2 serum samples were exclusively positive (P < 0.05). At the time of clinical CMV infection, viral copy numbers were higher in PBMNs than serum from four of five patients. The COBAS AMPLICOR CMV MONITOR test is a sensitive and specific test for the quantitative detection of CMV DNA in blood. Clinical applications of the assay will require further validation with samples from a larger population of transplant patients. PMID:10655353
Holtkötter, Hannah; Dias Filho, Claudemir Rodrigues; Schwender, Kristina; Stadler, Christian; Vennemann, Marielle; Pacheco, Ana Claudia; Roca, Gabriela
2018-05-01
Sexual assault is a serious offense and identification of body fluids originating from sexual activity has been a crucial aspect of forensic investigations for a long time. While reliable tests for the detection of semen and saliva have been successfully implemented into forensic laboratories, the detection of other body fluids, such as vaginal or menstrual fluid, is more challenging. Especially, the discrimination between peripheral and menstrual blood can be highly relevant for police investigations because it provides potential evidence regarding the issue of consent. We report the forensic validation of an immunochromatographic test that allows for such discrimination in forensic stains, the SERATEC PMB test, and its performance on real casework samples. The PMB test is a duplex test combining human hemoglobin and D-dimer detection and was developed for the identification of blood and menstrual fluid, both at the crime scene and in the laboratory. The results of this study showed that the duplex D-dimer/hemoglobin assay reliably detects the presence of human hemoglobin and identifies samples containing menstrual fluid by detecting the presence of D-dimers. The method distinguished between menstrual and peripheral blood in a swab from a historical artifact and in real casework samples of alleged sexual assaults. Results show that the development of the new duplex test is a substantial progress towards analyzing and interpreting evidence from sexual assault cases.
Bezos, Javier; Roy, Álvaro; Infantes-Lorenzo, José Antonio; González, Isabel; Venteo, Ángel; Romero, Beatriz; Grau, Anna; Mínguez, Olga; Domínguez, Lucas; de Juan, Lucía
2018-05-01
The diagnosis of tuberculosis (TB) in goats is based mainly on the single and comparative intradermal tuberculin (SIT and CIT) tests and, exceptionally, on the interferon-gamma (IFN-γ) assay, however they are not perfect in terms of sensitivity and specificity. Nevertheless, various serological assays that provide a potential cost-effective approach for the control of TB are also available or under development, and a variety of results have been reported regarding the ability of these tests to detect infected animals, particularly in the early stages of infection. In the present study, SIT/CIT and IFN-γ tests and three different serological assays were evaluated during two consecutive herd testing events in a recently infected caprine herd (n = 447) with a high prevalence of infection in order to evaluate their performance and provide field data with which to improve the TB control programs in this species. The proportion of infected animals that tested positive among all the infected goats (T+/I+ value) in the last herd testing event ranged from 26.2% (IC95%; 19.3-34.5) to 85.7% (IC95%; 78.5-90.7) using cell-based diagnostic tests. The SIT/SCIT tests detected more infected goats than the IFN-γ test, regardless of the interpretation criteria. The T+/I+ value of serology was 83.2 (IC95%; 75.2-89), although it increased significantly (P < 0.05) when using samples collected 15 days after the intradermal test (100%, IC95%; 97-100). In general, a parallel interpretation of intradermal tests with serology maximized the detection of infected goats. These results demonstrate that serological tests are valuable diagnostic tools to maximize the detection of TB infected goats, even in recent outbreaks, accelerating the eradication process. Copyright © 2018 Elsevier B.V. All rights reserved.
Lau, Lily; Basso, Michael R; Estevis, Eduardo; Miller, Ashley; Whiteside, Douglas M; Combs, Dennis; Arentsen, Timothy J
2017-11-01
Performance validity tests (PVTs) and symptom validity tests (SVTs) are often administered during neuropsychological evaluations. Examinees may be coached to avoid detection by measures of response validity. Relatively little research has evaluated whether graduated levels of coaching has differential effects upon PVT and SVT performance. Accordingly, the present experiment evaluated the effect of graduated levels of coaching upon the classification accuracy of commonly used PVTs and SVTs and the currently accepted criterion of failing two or more PVTs or SVTs. Participants simulated symptoms associated with mild traumatic brain injury (TBI). One group was provided superficial information concerning cognitive, emotional, and physical symptoms. Another group was provided detailed information about such symptoms. A third group was provided detailed information about symptoms and guidance how to evade detection by PVTs. These groups were compared to an honest-responding group. Extending prior experiments, stand-alone and embedded PVT measures were administered in addition to SVTs. The three simulator groups were readily identified by PVTs and SVTs, but a meaningful minority of those provided test-taking strategies eluded detection. The Word Memory Test emerged as the most sensitive indicator of simulated mild TBI symptoms. PVTs achieved more sensitive detection of simulated head injury status than SVTs. Individuals coached to modify test-taking performance were marginally more successful in eluding detection by PVTs and SVTs than those coached with respect to TBI symptoms only. When the criterion of failing two or more PVTs or SVTs was applied, only 5% eluded detection.
Evaluation of different methods to detect methicillin resistance in Staphylococcus aureus (MRSA).
Alipour, Farzad; Ahmadi, Malahat; Javadi, Shahram
2014-01-01
The studies suggest that dogs living with human are potential risk of becoming MRSA carrier and increased risk of infections caused by MRSA. Phenotypic methods to detect methicillin resistance in Staphylococcus aureus (MRSA) are inadequate. The objective of the present study was to determine methicillin resistance in S. aureus by phenotypic susceptibility test (oxacillin disk diffusion, cefoxitin disk diffusion, oxacillin screen agar) and molecular methods (PCR as a gold standard) and the latex agglutination test for the detection of PBP2a and to evaluate the results of these tests for its sensitivity and specificity. A total of 100 swab samples were taken from muzzle site, in more contact with human, of dogs and MRSA were isolated. Oxacillin (1 μg), cefoxitin (30 μg) disk diffusion and oxacillin screen agar method were used. The isolates were also subjected to latex agglutination test for detection of PBP2a and PCR to detect mecA gene. By PCR 37% of isolates show the presence of mecA. Latex agglutination was found to be the most sensitive (97.29%) and cefoxitin disk diffusion to be the most specific (96.82%) tests for detection of MRSA. Our finding showed that combining oxacillin screen agar or cefoxitin disk diffusion with latex agglutination improves sensitivity and specificity to detect methicillin resistance S. aureus (MRSA) isolates. Copyright © 2014 King Saud Bin Abdulaziz University for Health Sciences. Published by Elsevier Ltd. All rights reserved.
Detection limits of the strip test and PCR for genetically modified corn in Brazil.
Nascimento, V E; Von Pinho, É V R; Von Pinho, R G; do Nascimento, A D
2012-08-16
Brazilian legislation establishes a labeling limit for products that contain more than 1% material from genetically modified organisms (GMOs). We assessed the sensitivity of the lateral flow strip test in detection of the GMO corn varieties Bt11 and MON810 and the specificity and sensitivity of PCR techniques for their detection. For the strip test, the GMO seeds were mixed with conventional seeds at levels of 0.2, 0.4 and 0.8% for Bt11, and 0.4, 0.8 and 1.6% for MON810. Three different methodologies were assessed and whole seeds, their endosperm and embryonic axis were used. For the PCR technique, the GMO seeds of each of the two varieties were mixed with conventional seeds at levels of 20, 10, 5, 2, 1, and 0.5%. The seeds were ground and the DNA extracted. For detection of the GMO material, specific primers were used for MON810 and Bt11 and maize zein as an endogenous control. The sensitivity of the strip test varied for both maize varieties and methodologies. The test was positive for Bt11 only at 0.8%, in contrast with the detection limit of 0.4% indicated by the manufacturer. In the multiplex PCR, the primers proved to be specific for the different varieties. These varieties were detected in samples with one GMO seed in 100. Thus, this technique proved to be efficient in detecting contaminations equal to or greater than 1%.
Integrated Remote Sensing Modalities for Classification at a Legacy Test Site
NASA Astrophysics Data System (ADS)
Lee, D. J.; Anderson, D.; Craven, J.
2016-12-01
Detecting, locating, and characterizing suspected underground nuclear test sites is of interest to the worldwide nonproliferation monitoring community. Remote sensing provides both cultural and surface geological information over a large search area in a non-intrusive manner. We have characterized a legacy nuclear test site at the Nevada National Security Site (NNSS) using an aerial system based on RGB imagery, light detection and ranging, and hyperspectral imaging. We integrate these different remote sensing modalities to perform pattern recognition and classification tasks on the test site. These tasks include detecting cultural artifacts and exotic materials. We evaluate if the integration of different remote sensing modalities improves classification performance.
[Automated analyzer of enzyme immunoassay].
Osawa, S
1995-09-01
Automated analyzers for enzyme immunoassay can be classified by several points of view: the kind of labeled antibodies or enzymes, detection methods, the number of tests per unit time, analytical time and speed per run. In practice, it is important for us consider the several points such as detection limits, the number of tests per unit time, analytical range, and precision. Most of the automated analyzers on the market can randomly access and measure samples. I will describe the recent advance of automated analyzers reviewing their labeling antibodies and enzymes, the detection methods, the number of test per unit time and analytical time and speed per test.
NASA Technical Reports Server (NTRS)
Leibecki, H. F.
1980-01-01
One hundred and forty-six 20 ampere-hour sealed nickel cadmium cells from five manufacturers were detected using preliminary tests which do not require life testing and do not reduce the expected life of the cells. Differences between individual cells were also detected, using these tests, allowing a comparison of variability of cell construction by and between manufacturers.
A Novel Technique for Detecting Antibiotic-Resistant Typhoid from Rapid Diagnostic Tests
Nic Fhogartaigh, Caoimhe; Dance, David A. B.; Davong, Viengmon; Tann, Pisey; Phetsouvanh, Rattanaphone; Turner, Paul; Newton, Paul N.
2015-01-01
Fluoroquinolone-resistant typhoid is increasing. An antigen-detecting rapid diagnotic test (RDT) can rapidly diagnose typhoid from blood cultures. A simple, inexpensive molecular technique performed with DNA from positive RDTs accurately identified gyrA mutations consistent with phenotypic susceptibility testing results. Field diagnosis combined with centralized molecular resistance testing could improve typhoid management and surveillance in low-resource settings. PMID:25762768
The early identification of psychosis: Can lessons be learnt from Cardiac Stress Testing?
Gupta, Swapnil; Ranganathan, Mohini; D’Souza, Deepak Cyril
2015-01-01
Psychotic disorders including schizophrenia are amongst the most debilitating psychiatric disorders. There is an urgent need to develop methods to identify individuals at risk with greater precision and as early as possible. At present, a prerequisite for a diagnosis of schizophrenia is the occurrence of a psychotic episode. Therefore, attempting to detect schizophrenia on the basis of psychosis is analogous to diagnosing coronary artery disease (CAD) after the occurrence of a myocardial infarction (MI). The introduction of cardiac stress testing (CST) has revolutionized the detection of CAD and the prevention and management of angina and MI. In this paper we attempt to apply lessons learnt from cardiac stress testing to the early detection of psychosis by proposing the development of an analogous psychosis stress test. We discuss in detail the various parameters of a proposed psychosis stress test including the choice of a suitable psychological or psychopharmacological “stressor”, target population, outcome measures, safety of the approach and the necessary evolution of test to become clinically informative. The history of evolution of CST may guide the development of a similar approach for the detection and management of psychotic disorders. The initial development of a test to unmask latent risk for schizophrenia will require the selection of a suitable and safe stimulus and the development of outcome measures as a prelude to testing in populations with a range of risk to determine predictive value. The use of cardiac stress testing in coronary artery disease offers the intriguing possibility that a similar approach may be applied to the detection and management of schizophrenia. PMID:26566609
Dussart, Philippe; Petit, Laure; Labeau, Bhety; Bremand, Laetitia; Leduc, Alexandre; Moua, David; Matheus, Séverine; Baril, Laurence
2008-08-20
We compared the performance of two new commercial tests for the detection of dengue NS1 protein during the clinical phase of dengue virus (DENV) infection-an immunochromatographic test allowing rapid detection of the NS1 antigen, Dengue NS1 Ag STRIP (Bio-Rad Laboratories - Marnes La Coquette, France), and a two-step sandwich-format microplate enzyme-linked immunosorbent assay (ELISA), pan-E Dengue Early ELISA (Panbio - Brisbane, Australia)-with a one-step sandwich-format microplate ELISA, the Platelia Dengue NS1 Ag test (Bio-Rad). We tested 272 serum samples from patients with dengue disease. Of these, 222 were from patients with acute infection of one of the four dengue serotypes, detected by RT-PCR and/or virus isolation. Forty-eight acute-phase serum samples from patients not infected with dengue virus were also included. The sensitivity of the Platelia Dengue NS1 Ag test on acute serum samples (n = 222) was 87.4% (95% confidence interval: 82.3% to 91.5%); that of Dengue NS1 Ag STRIP was 81.5% (95% CI: 75.8% to 86.4%) after 15 minutes and 82.4% (95% CI: 76.8% to 87.2%) after 30 minutes. Both tests had a specificity of 100% (97.5% CI, one-sided test: 92.6% to 100.0%). The pan-E Dengue Early ELISA had a sensitivity of 60.4% (95% CI: 53.4% to 66.8%) and a specificity of 97.9% (95% CI: 88.9% to 99.9%). Our findings support the use of diagnostic tools based on the NS1 antigen detection for the diagnosis of acute DENV infection. The immunochromatographic test, Dengue NS1 Ag STRIP-the first rapid diagnostic test for DENV infection-was highly sensitive and specific, and would therefore be a suitable first-line test in the field. The pan-E Dengue Early ELISA was less sensitive than the Platelia test; this two-step ELISA should be combined with DENV IgM antibody detection for the diagnosis of DENV infection.
[Validation of three screening tests used for early detection of cervical cancer].
Rodriguez-Reyes, Esperanza Rosalba; Cerda-Flores, Ricardo M; Quiñones-Pérez, Juan M; Cortés-Gutiérrez, Elva I
2008-01-01
to evaluate the validity (sensitivity, specificity, and accuracy) of three screening methods used in the early detection of the cervical carcinoma versus the histopathology diagnosis. a selected sample of 107 women attended in the Opportune Detection of Cervicouterine Cancer Program in the Hospital de Zona 46, Instituto Mexicano del Seguro Social in Durango, during the 2003 was included. The application of Papa-nicolaou, acetic acid test, and molecular detection of human papillomavirus, and histopatholgy diagnosis were performed in all the patients at the time of the gynecological exam. The detection and tipification of the human papillomavirus was performed by polymerase chain reaction (PCR) and analysis of polymorphisms of length of restriction fragments (RFLP). Histopathology diagnosis was considered the gold standard. The evaluation of the validity was carried out by the Bayesian method for diagnosis test. the positive cases for acetic acid test, Papanicolaou, and PCR were 47, 22, and 19. The accuracy values were 0.70, 0.80 and 0.99, respectively. since the molecular method showed a greater validity in the early detection of the cervical carcinoma we considered of vital importance its implementation in suitable programs of Opportune Detection of Cervicouterino Cancer Program in Mexico. However, in order to validate this conclusion, cross-sectional studies in different region of country must be carried out.
Vitkova, O N; Kapustina, T P; Mikhailova, V V; Safonov, G A; Vlasova, N N; Belousova, R V
2015-01-01
The goal of this work was to demonstrate the results of the development of the enzyme-linked immunosorbent tests with chemiluminescence detection and colorimetric detection of specific viral antigens and antibodies for identifying the avian influenza and the Newcastle disease viruses: high sensitivity and specificity of the immuno- chemiluminescence assay, which are 10-50 times higher than those of the ELISA colorimetric method. The high effectiveness of the results and the automation of the process of laboratory testing (using a luminometer) allow these methods to be recommended for including in primary screening tests for these infectious diseases.
Hearing aid malfunction detection system
NASA Technical Reports Server (NTRS)
Kessinger, R. L. (Inventor)
1977-01-01
A malfunction detection system for detecting malfunctions in electrical signal processing circuits is disclosed. Malfunctions of a hearing aid in the form of frequency distortion and/or inadequate amplification by the hearing aid amplifier, as well as weakening of the hearing aid power supply are detectable. A test signal is generated and a timed switching circuit periodically applies the test signal to the input of the hearing aid amplifier in place of the input signal from the microphone. The resulting amplifier output is compared with the input test signal used as a reference signal. The hearing aid battery voltage is also periodically compared to a reference voltage. Deviations from the references beyond preset limits cause a warning system to operate.
Monte Carlo criticality source convergence in a loosely coupled fuel storage system.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Blomquist, R. N.; Gelbard, E. M.
2003-06-10
The fission source convergence of a very loosely coupled array of 36 fuel subassemblies with slightly non-symmetric reflection is studied. The fission source converges very slowly from a uniform guess to the fundamental mode in which about 40% of the fissions occur in one corner subassembly. Eigenvalue and fission source estimates are analyzed using a set of statistical tests similar to those used in MCNP, including the ''drift-in-mean'' test and a new drift-in-mean test using a linear fit to the cumulative estimate drift, the Shapiro-Wilk test for normality, the relative error test, and the ''1/N'' test. The normality test doesmore » not detect a drifting eigenvalue or fission source. Applied to eigenvalue estimates, the other tests generally fail to detect an unconverged solution, but they are sometimes effective when evaluating fission source distributions. None of the test provides completely reliable indication of convergence, although they can detect nonconvergence.« less
NASA Astrophysics Data System (ADS)
Stetson, Suzanne; Weber, Hadley; Crosby, Frank J.; Tinsley, Kenneth; Kloess, Edmund; Nevis, Andrew J.; Holloway, John H., Jr.; Witherspoon, Ned H.
2004-09-01
The Airborne Littoral Reconnaissance Technologies (ALRT) project has developed and tested a nighttime operational minefield detection capability using commercial off-the-shelf high-power Laser Diode Arrays (LDAs). The Coastal System Station"s ALRT project, under funding from the Office of Naval Research (ONR), has been designing, developing, integrating, and testing commercial arrays using a Cessna airborne platform over the last several years. This has led to the development of the Airborne Laser Diode Array Illuminator wide field-of-view (ALDAI-W) imaging test bed system. The ALRT project tested ALDAI-W at the Army"s Night Vision Lab"s Airborne Mine Detection Arid Test. By participating in Night Vision"s test, ALRT was able to collect initial prototype nighttime operational data using ALDAI-W, showing impressive results and pioneering the way for final test bed demonstration conducted in September 2003. This paper describes the ALDAI-W Arid Test and results, along with processing steps used to generate imagery.
Tang, Zhiteng; Xu, Ye; Song, Najie; Zou, Dongqing; Liao, Yiqun; Li, Qingge; Pan, Chao
2018-03-01
The clinical performance of the newly developed MeltPro ® HPV Test, based on multicolor melting curve analysis, was evaluated and compared with the commercially available Cobas ® HPV Test for detection of HPV and genotyping of HPV-16 and HPV-18. A total of 1647 cervical samples were analyzed with both tests. The agreement values were 96.2% for HPV detection, 99.6% for HPV-16 identification, and 99.7% for HPV-18 identification. All genotyping results from MeltPro ® HPV Test showed that HPV-52, HPV-58, and HPV-16 were the most common types in this study. Intra-laboratory reproducibility studies showed 97.8% agreement while inter-laboratory reproducibility studies showed 96.9% agreement for the MeltPro ® HPV Test. The MeltPro ® HPV Test and Cobas ® HPV Test are highly correlative and are useful for monitoring HPV infection.
Laser-based standoff detection of explosives: a critical review.
Wallin, Sara; Pettersson, Anna; Ostmark, Henric; Hobro, Alison
2009-09-01
A review of standoff detection technologies for explosives has been made. The review is focused on trace detection methods (methods aiming to detect traces from handling explosives or the vapours surrounding an explosive charge due to the vapour pressure of the explosive) rather than bulk detection methods (methods aiming to detect the bulk explosive charge). The requirements for standoff detection technologies are discussed. The technologies discussed are mostly laser-based trace detection technologies, such as laser-induced-breakdown spectroscopy, Raman spectroscopy, laser-induced-fluorescence spectroscopy and IR spectroscopy but the bulk detection technologies millimetre wave imaging and terahertz spectroscopy are also discussed as a complement to the laser-based methods. The review includes novel techniques, not yet tested in realistic environments, more mature technologies which have been tested outdoors in realistic environments as well as the most mature millimetre wave imaging technique.
High risk HPV testing following treatment for cervical intraepithelial neoplasia.
Molloy, M; Comer, R; Rogers, P; Dowling, M; Meskell, P; Asbury, K; O'Leary, M
2016-11-01
To determine the results of combined cytology and high-risk human papilloma virus (HR HPV) tests at 6 and 18 months postcolposcopy treatment at one Irish colposcopy centre. All women who attended the centre's colposcopy smear clinic for a co-test 6 months (initial test) posttreatment were included in the audit (n = 251). The results revealed negative HR HPV for 79 % (n = 198) of women tested 6 months after treatment and positive results for 21 % (n = 53). HR HPV testing was more sensitive than cytology and led to early detection of residual disease. No women with negative HR HPV had high-grade cytology. HR HPV is more sensitive than cytology for detection of persistent CIN. However, 19 women with positive HR HPV had normal colposcopy with no persistent CIN detected. A national cost-benefit analysis is recommended to determine the value of the second co-test.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-23
... DEPARTMENT OF HEALTH AND HUMAN SERVICES Nomination of In Vitro Test Methods for Detection and... Evaluated by These Test Methods AGENCY: Division of National Toxicology Program (NTP), National Institute of... Methods (ICCVAM), the NTP Interagency Center for the Evaluation of Alternative Toxicological Methods...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-14
... development of BG1Luc ER TA test method performance standards. ICCVAM assigned the activities a high priority... Vitro Test Methods for Detecting Potential Endocrine Disruptors. Research Triangle Park, NC: National...Final.pdf . ICCVAM. 2003a. ICCVAM Evaluation of In Vitro Test Methods For Detecting Potential Endocrine...
USDA-ARS?s Scientific Manuscript database
Facing the increasing food safety issues, Chinese government has been carrying out compulsory tests on food to meet the requirements of domestic and foreign markets. Colloidal-gold test strips using the colorimetric principle are widely used for rapid qualitative detection of harmful residues in fo...
From the lab - CancerSEEK: Blood Test Could Detect Cancer Earlier | NIH MedlinePlus the Magazine
... is supported by NIH, in a recent blog post. “CancerSEEK was able to detect most cases of eight different kinds of cancer, including some highly lethal forms that currently lack screening tests,” Dr. Collins said. The CancerSEEK trial tested breast, ...
Detection of Item Preknowledge Using Likelihood Ratio Test and Score Test
ERIC Educational Resources Information Center
Sinharay, Sandip
2017-01-01
An increasing concern of producers of educational assessments is fraudulent behavior during the assessment (van der Linden, 2009). Benefiting from item preknowledge (e.g., Eckerly, 2017; McLeod, Lewis, & Thissen, 2003) is one type of fraudulent behavior. This article suggests two new test statistics for detecting individuals who may have…
Cabrieto, Jedelyn; Tuerlinckx, Francis; Kuppens, Peter; Hunyadi, Borbála; Ceulemans, Eva
2018-01-15
Detecting abrupt correlation changes in multivariate time series is crucial in many application fields such as signal processing, functional neuroimaging, climate studies, and financial analysis. To detect such changes, several promising correlation change tests exist, but they may suffer from severe loss of power when there is actually more than one change point underlying the data. To deal with this drawback, we propose a permutation based significance test for Kernel Change Point (KCP) detection on the running correlations. Given a requested number of change points K, KCP divides the time series into K + 1 phases by minimizing the within-phase variance. The new permutation test looks at how the average within-phase variance decreases when K increases and compares this to the results for permuted data. The results of an extensive simulation study and applications to several real data sets show that, depending on the setting, the new test performs either at par or better than the state-of-the art significance tests for detecting the presence of correlation changes, implying that its use can be generally recommended.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Geng, Rongli; Daly, Edward; Drury, Michael
2015-09-01
We report on the first result of at-cavity X-ray detection in a CEBAF cryomodule for field emission monitoring. In the 8-cavity cryomodule F100, two silicon diodes were installed near the end flange of each cavity. Each cavity was individually tested during the cryomodule test in JLab’s cryomodule test facility. The behaviors of these at-cavity cryogenic X-ray detectors were compared with those of the standard ‘in air’ Geiger-Muller (G-M) tubes. Our initial experiments establish correlation between X-ray response of near diodes and the field emission source cavity in the 8-cavity string. For two out of these eight cavities, we also carriedmore » out at-cavity X-ray detection experiment during their vertical testing. The aim is to track field emission behavior uniquely from vertical cavity testing to horizontal cavity testing in the cryomodule. These preliminary results confirmed our expectation and warrant further effort toward the establishment of permanent at-cavity cryogenic X-ray detection for SRF development and operation.« less
NASA Astrophysics Data System (ADS)
Ni, Zhengyuan; Yan, Huimin; Ni, Xuxiang; Zhang, Xiuda
2017-10-01
The research of the multifunctional analyzer which integrates absorbance detection, fluorescence detection, time-resolved fluorescence detection, biochemical luminescence detection methods, can make efficient detection and analysis for a variety of human body nutrients. This article focuses on the absorbance detection and fluorescence detection system. The two systems are modular in design and controlled by embedded system, to achieve automatic measurement according to user settings. In the optical path design, the application of confocal design can improve the optical signal acquisition capability, and reduce the interference. A photon counter is used for detection, and a high performance counter module is designed to measure the output of photon counter. In the experiment, we use neutral density filters and potassium dichromate solution to test the absorbance detection system, and use fluorescein isothiocyanate FITC for fluorescence detection system performance test. The experimental results show that the absorbance detection system has a detection range of 0 4OD, and has good linearity in the detection range, while the fluorescence detection system has a high sensitivity of 1pmol/L concentration.
Arthur, Terrance M; Bosilevac, Joseph M; Nou, Xiangwu; Koohmaraie, Mohammad
2005-08-01
Currently, several beef processors employ test-and-hold systems for increased quality control of ground beef. In such programs, each lot of product must be tested and found negative for Escherichia coli O157:H7 prior to release of the product into commerce. Optimization of three testing attributes (detection time, specificity, and sensitivity) is critical to the success of such strategies. Because ground beef is a highly perishable product, the testing methodology used must be as rapid as possible. The test also must have a low false-positive result rate so product is not needlessly discarded. False-negative results cannot be tolerated because they would allow contaminated product to be released and potentially cause disease. In this study, two culture-based and three PCR-based methods for detecting E. coli O157:H7 in ground beef were compared for their abilities to meet the above criteria. Ground beef samples were individually spiked with five genetically distinct strains of E. coli O157: H7 at concentrations of 17 and 1.7 CFU/65 g and then subjected to the various testing methodologies. There was no difference (P > 0.05) in the abilities of the PCR-based methods to detect E. coli O157:H7 inoculated in ground beef at 1.7 CFU/65 g. The culture-based systems detected more positive samples than did the PCR-based systems, but the detection times (21 to 48 h) were at least 9 h longer than those for the PCR-based methods (7.5 to 12 h). Ground beef samples were also spiked with potentially cross-reactive strains. The PCR-based systems that employed an immunomagnetic separation step prior to detection produced fewer false-positive results.
Can Handheld Thermal Imaging Technology Improve Detection of Poachers in African Bushveldt?
Dandy, Shantelle; Stubbs, Hannah; MacTavish, Dougal; MacTavish, Lynne
2015-01-01
Illegal hunting (poaching) is a global threat to wildlife. Anti-poaching initiatives are making increasing use of technology, such as infrared thermography (IRT), to support traditional foot and vehicle patrols. To date, the effectiveness of IRT for poacher location has not been tested under field conditions, where thermal signatures are often complex. Here, we test the hypothesis that IRT will increase the distance over which a poacher hiding in African scrub bushveldt can be detected relative to a conventional flashlight. We also test whether any increase in effectiveness is related to the cost and complexity of the equipment by comparing comparatively expensive (22000 USD) and relatively inexpensive (2000 USD) IRT devices. To test these hypotheses we employ a controlled, fully randomised, double-blind procedure to find a poacher in nocturnal field conditions in African bushveldt. Each of our 27 volunteer observers walked three times along a pathway using one detection technology on each pass in randomised order. They searched a prescribed search area of bushveldt within which the target was hiding. Hiding locations were pre-determined, randomised, and changed with each pass. Distances of first detection and positive detection were noted. All technologies could be used to detect the target. Average first detection distance for flashlight was 37.3m, improving by 19.8m to 57.1m using LIRT and by a further 11.2m to 68.3m using HIRT. Although detection distances were significantly greater for both IRTs compared to flashlight, there was no significant difference between LIRT and HIRT. False detection rates were low and there was no significant association between technology and accuracy of detection. Although IRT technology should ideally be tested in the specific environment intended before significant investment is made, we conclude that IRT technology is promising for anti-poaching patrols and that for this purpose low cost IRT units are as effective as units ten times more expensive. PMID:26110865
Chapinal, Núria; Schumaker, Brant A; Joly, Damien O; Elkin, Brett T; Stephen, Craig
2015-07-01
We estimated the sensitivity and specificity of the caudal-fold skin test (CFT), the fluorescent polarization assay (FPA), and the rapid lateral-flow test (RT) for the detection of Mycobacterium bovis in free-ranging wild wood bison (Bison bison athabascae), in the absence of a gold standard, by using Bayesian analysis, and then used those estimates to forecast the performance of a pairwise combination of tests in parallel. In 1998-99, 212 wood bison from Wood Buffalo National Park (Canada) were tested for M. bovis infection using CFT and two serologic tests (FPA and RT). The sensitivity and specificity of each test were estimated using a three-test, one-population, Bayesian model allowing for conditional dependence between FPA and RT. The sensitivity and specificity of the combination of CFT and each serologic test in parallel were calculated assuming conditional independence. The test performance estimates were influenced by the prior values chosen. However, the rank of tests and combinations of tests based on those estimates remained constant. The CFT was the most sensitive test and the FPA was the least sensitive, whereas RT was the most specific test and CFT was the least specific. In conclusion, given the fact that gold standards for the detection of M. bovis are imperfect and difficult to obtain in the field, Bayesian analysis holds promise as a tool to rank tests and combinations of tests based on their performance. Combining a skin test with an animal-side serologic test, such as RT, increases sensitivity in the detection of M. bovis and is a good approach to enhance disease eradication or control in wild bison.
Kania, Dramane; Truong, Tam Nguyen; Montoya, Ana; Nagot, Nicolas; Van de Perre, Philippe; Tuaillon, Edouard
2015-01-01
Point-of-care testing and diagnosis of HIV acute infections play important roles in preventing transmission, but HIV rapid diagnosis tests have poor capacity to detect early infections. Filter paper can be used for capillary blood collection and HIV testing using 4th generation immunoassays. Antigen/antibody combined immunoassays were evaluated for their capacity to identify early HIV infections using filter paper in comparison with rapid test. Thirty nine serum samples collected from HIV seroconverters were spotted onto filter paper and tested by the Roche Elecsys(®) HIV Combi PT test and the DiaSorin Liaison XL Murex HIV Ab/Ag assay. Fourth generation immunoassays identified 34 out of 39 HIV early infections using dried serum spot, whereas the Determine™ HIV-1/2 rapid test detected 24 out of 39 HIV positive serum (87.2% vs 61.5% respectively, p = 0.009). p24 antigen was detected by the Liaison XL in 19 dried serum samples (48.7%). In the group characterized by a negative western blot, 7 out of 8 (87.5%) and 6 out of 8 (75.0%) samples were found positive for HIV using the Elecsys and the Liaison XL, respectively. None of these eight samples classified in this group of early acute infections were found positive by the rapid test. Fourth generation Ag/Ab immunoassays performed on dried serum spot had good performance for HIV testing during the early phases of HIV infection. This method may be useful to detect HIV early infections in hard-to-reach populations and individuals living in remote areas before rapid tests become positive. Copyright © 2014 Elsevier B.V. All rights reserved.
A Smartphone App to Screen for HIV-Related Neurocognitive Impairment
Robbins, Reuben N.; Brown, Henry; Ehlers, Andries; Joska, John A.; Thomas, Kevin G.F.; Burgess, Rhonda; Byrd, Desiree; Morgello, Susan
2014-01-01
Background Neurocognitive Impairment (NCI) is one of the most common complications of HIV-infection, and has serious medical and functional consequences. However, screening for it is not routine and NCI often goes undiagnosed. Screening for NCI in HIV disease faces numerous challenges, such as limited screening tests, the need for specialized equipment and apparatuses, and highly trained personnel to administer, score and interpret screening tests. To address these challenges, we developed a novel smartphone-based screening tool, NeuroScreen, to detect HIV-related NCI that includes an easy-to-use graphical user interface with ten highly automated neuropsychological tests. Aims To examine NeuroScreen’s: 1) acceptability among patients and different potential users; 2) test construct and criterion validity; and 3) sensitivity and specificity to detect NCI. Methods Fifty HIV+ individuals were administered a gold-standard neuropsychological test battery, designed to detect HIV-related NCI, and NeuroScreen. HIV+ test participants and eight potential provider-users of NeuroScreen were asked about its acceptability. Results There was a high level of acceptability of NeuroScreen by patients and potential provider-users. Moderate to high correlations between individual NeuroScreen tests and paper-and-pencil tests assessing the same cognitive domains were observed. NeuroScreen also demonstrated high sensitivity to detect NCI. Conclusion NeuroScreen, a highly automated, easy-to-use smartphone-based screening test to detect NCI among HIV patients and usable by a range of healthcare personnel could help make routine screening for HIV-related NCI feasible. While NeuroScreen demonstrated robust psychometric properties and acceptability, further testing with larger and less neurocognitively impaired samples is warranted. PMID:24860624
Hypothesis tests for the detection of constant speed radiation moving sources
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dumazert, Jonathan; Coulon, Romain; Kondrasovs, Vladimir
2015-07-01
Radiation Portal Monitors are deployed in linear network to detect radiological material in motion. As a complement to single and multichannel detection algorithms, inefficient under too low signal to noise ratios, temporal correlation algorithms have been introduced. Test hypothesis methods based on empirically estimated mean and variance of the signals delivered by the different channels have shown significant gain in terms of a tradeoff between detection sensitivity and false alarm probability. This paper discloses the concept of a new hypothesis test for temporal correlation detection methods, taking advantage of the Poisson nature of the registered counting signals, and establishes amore » benchmark between this test and its empirical counterpart. The simulation study validates that in the four relevant configurations of a pedestrian source carrier under respectively high and low count rate radioactive background, and a vehicle source carrier under the same respectively high and low count rate radioactive background, the newly introduced hypothesis test ensures a significantly improved compromise between sensitivity and false alarm, while guaranteeing the stability of its optimization parameter regardless of signal to noise ratio variations between 2 to 0.8. (authors)« less
NASA Astrophysics Data System (ADS)
Sulistyowati, Riny; Sujono, Hari Agus; Musthofa, Ahmad Khamdi
2017-06-01
Due to the high rainfall, flood often occurs in some regions, especially in the area adjacent to the river banks that led to the idea to make the river water level detection system as a flood early warning. Several researches have produced flood detection equipment based on ultrasonic sensors and android as flood early warning system. This paper reported the results of a field test detection equipment to measure the river water level of the Bengawansolo River that was conducted in three villages in the district of Bungah, Dukun, and Manyar in Gresik regency. Tests were conducted simultaneously for 21 hours during heavy rainfall. The test results demonstrated the accuracy of the equipment of 97.28% for all categories of observation. The application of AFD (Android Flood Detection) via android smartphone demonstrated its precision in conveying the information of water level as represented by the status of SAFE, STAND, WARNING, and DANGER. Some charts presented from the analysis of data was derived from the data acquisition time of testing that can be used as an evaluation of flooding at some points prone to flood.
Reaction times to weak test lights. [psychophysics biological model
NASA Technical Reports Server (NTRS)
Wandell, B. A.; Ahumada, P.; Welsh, D.
1984-01-01
Maloney and Wandell (1984) describe a model of the response of a single visual channel to weak test lights. The initial channel response is a linearly filtered version of the stimulus. The filter output is randomly sampled over time. Each time a sample occurs there is some probability increasing with the magnitude of the sampled response - that a discrete detection event is generated. Maloney and Wandell derive the statistics of the detection events. In this paper a test is conducted of the hypothesis that the reaction time responses to the presence of a weak test light are initiated at the first detection event. This makes it possible to extend the application of the model to lights that are slightly above threshold, but still within the linear operating range of the visual system. A parameter-free prediction of the model proposed by Maloney and Wandell for lights detected by this statistic is tested. The data are in agreement with the prediction.
An evaluation of the Monosticon rapid slide test diagnosis of infectious mononucleosis
Scott, G. L.; Priest, C. J.
1972-01-01
A new rapid slide test for the detection of infectious mononucleosis heterophile antibody has been compared with the Paul-Bunnell absorption test. Out of 200 sera, 46 were seropositive for infectious mononucleosis by the Paul-Bunnell test and 43 of these were detected by the Monosticon test; the three Monosticon-negative sera were of low titre. There was no problem with false positive reactions due to heterophile antibody not specific for infectious mononucleosis. PMID:4678188
Testing for nonlinear dependence in financial markets.
Dore, Mohammed; Matilla-Garcia, Mariano; Marin, Manuel Ruiz
2011-07-01
This article addresses the question of improving the detection of nonlinear dependence by means of recently developed nonparametric tests. To this end a generalized version of BDS test and a new test based on symbolic dynamics are used on realizations from a well-known artificial market for which the dynamic equation governing the market is known. Comparisons with other tests for detecting nonlinearity are also provided. We show that the test based on symbolic dynamics outperforms other tests with the advantage that it depends only on one free parameter, namely the embedding dimension. This does not hold for other tests for nonlinearity.
Transmission Bearing Damage Detection Using Decision Fusion Analysis
NASA Technical Reports Server (NTRS)
Dempsey, Paula J.; Lewicki, David G.; Decker, Harry J.
2004-01-01
A diagnostic tool was developed for detecting fatigue damage to rolling element bearings in an OH-58 main rotor transmission. Two different monitoring technologies, oil debris analysis and vibration, were integrated using data fusion into a health monitoring system for detecting bearing surface fatigue pitting damage. This integrated system showed improved detection and decision-making capabilities as compared to using individual monitoring technologies. This diagnostic tool was evaluated by collecting vibration and oil debris data from tests performed in the NASA Glenn 500 hp Helicopter Transmission Test Stand. Data was collected during experiments performed in this test rig when two unanticipated bearing failures occurred. Results show that combining the vibration and oil debris measurement technologies improves the detection of pitting damage on spiral bevel gears duplex ball bearings and spiral bevel pinion triplex ball bearings in a main rotor transmission.
DOT National Transportation Integrated Search
2016-08-01
The Federal Railroad Administration (FRA), Transportation Technology Center, Inc. (TTCI), and rail industry participants have : performed probability of detection (POD) assessments to evaluate nondestructive testing (NDT) technologies, which are : pr...
Ultrasonic detection of plate cracks in railway wheels
DOT National Transportation Integrated Search
1976-07-31
The results of experimental efforts established the feasibility of the detection of railway wheel plate cracks by an ultrasonic pulse echo testing technique from the tread surface. Feasibility and test sensitivities were established using artificial ...
Dasgupta, Amitava; Wahed, Amer; Wells, Alice
2002-02-01
Several adulterants are used to mask tests for abused drugs in urine. Adulterants such as "Klear" and "Whizzies" contain potassium nitrite, and "Urine Luck" contains pyridinium chlorochromate (PCC). The presence of these adulterants cannot be detected by routine specimen integrity checks (pH, specific gravity, and temperature). We developed rapid spot tests for detecting these adulterants in urine. Addition of 3% hydrogen peroxide in urine adulterated with PCC caused rapid formation of a dark brown color. In contrast, unadulterated urine turned colorless when hydrogen peroxide was added. When urine contaminated with nitrite and 2 to 3 drops of 2N hydrochloric acid were added to 2% aqueous potassium permanganate solution, the dark pink permanganate solution turned colorless immediately with effervescence. Urine contaminated with nitrite liberated iodine from potassium iodide solution in the presence of 2N hydrochloric acid. Urine adulterated with PCC also liberated iodine from potassium iodide in acid medium but did not turn potassium permanganate solution colorless. Urine specimens from volunteers and random urine samples that tested negative for drugs did not cause false-positive results. These rapid spot tests are useful for detecting adulterated urine to avoid false-negative drug tests.
Mohd Nasir, Mohd Desa; Parasakthi, Navaratnam
2004-06-01
The increasing prevalence of penicillin-resistant Streptococuus pneumoniae urges for fast and accurate susceptibility testing methods. This study evaluated the comparability of three commonly used techniques; disk diffusion, E-test and agar dilution, to detect penicillin susceptibility in clinical isolates of S. pneumoniae. Fifty pneumococcal isolates, obtained from patients at the University of Malaya Medical Centre, were selected to include both penicillin-susceptible strains and those that had decreased susceptibility (resistant and intermediate) to penicillin. The minimum inhibitory concentration (MIC) values of penicillin to serve as the reference was determined by the agar dilution method in which, based on the MIC breakpoints recommended by the National Committee for Clinical Laboratory Standards (NCCLS), 27 strains had decreased susceptibility to penicillin with 17 strains resistant and 10 intermediate. Comparing to the agar dilution method, oxacillin disk diffusion test detected all strains with decreased penicillin susceptibility as such while E-test showed a close agreement of susceptibility (92%) of the isolates to penicillin. This confirmed that oxacillin is a good screening test for S. pneumoniae isolates with decreased susceptibility to penicillin while E-test is very reliable for rapid and accurate detection of penicillin susceptibility.
Aida, Kazuo; Sugie, Toshihiko
2011-12-12
We propose a method of testing transmission fiber lines and distributed amplifiers. Multipath interference (MPI) is detected as a beat spectrum between a multipath signal and a direct signal using a synthesized chirped test signal with lightwave frequencies of f(1) and f(2) periodically emitted from a distributed feedback laser diode (DFB-LD). This chirped test pulse is generated using a directly modulated DFB-LD with a drive signal calculated using a digital signal processing technique (DSP). A receiver consisting of a photodiode and an electrical spectrum analyzer (ESA) detects a baseband power spectrum peak appearing at the frequency of the test signal frequency deviation (f(1)-f(2)) as a beat spectrum of self-heterodyne detection. Multipath interference is converted from the spectrum peak power. This method improved the minimum detectable MPI to as low as -78 dB. We discuss the detailed design and performance of the proposed test method, including a DFB-LD drive signal calculation algorithm with DSP for synthesis of the chirped test signal and experiments on single-mode fibers with discrete reflections. © 2011 Optical Society of America
Efficacy of lures and hair snares to detect lynx
Gregory W. McDaniel; Kevin S. McKelvey; John R. Squires; Leonard F. Ruggiero
2000-01-01
Resource managers lack an inexpensive and quantifiable method to detect lynx presence across large landscapes. We tested efficacy of a protocol based on hair snagging to detect presence of lynx (Lynx canadensis). We tested 2 key elements of the protocol: 1) a hair-snaring device and 2) commercial lures used to attract and elicit rubbing behavior in lynx. The...
F.N. Martin; M.D. Coffey; K. Zeller; R.C. Hamelin; P. Tooley; M. Garbelotto; K.J.D. Hughes; T. Kubisiak; G.J. Bilodeau; L. Levy; C. Blomquist; P.H. Berger
2009-01-01
Given the importance of Phytophthora ramorum from a regulatory standpoint, it is imperative that molecular markers for pathogen detection are fully tested to evaluate their specificity in detection of the pathogen. In an effort to evaluate 11 reported diagnostic techniques, we assembled a standardized DNA library using accessions from the World...
Molecular diagnostics for human leptospirosis.
Waggoner, Jesse J; Pinsky, Benjamin A
2016-10-01
The definitive diagnosis of leptospirosis, which results from infection with spirochetes of the genus Leptospira, currently relies on the use of culture, serological testing (microscopic agglutination testing), and molecular detection. The purpose of this review is to describe new molecular diagnostics for Leptospira and discuss advancements in the use of available methods. Efforts have been focused on improving the clinical sensitivity of Leptospira detection using molecular methods. In this review, we describe a reoptimized pathogenic species-specific real-time PCR (targeting lipL32) that has demonstrated improved sensitivity, findings by two groups that real-time reverse-transcription PCR assays targeting the 16S rrs gene can improve detection, and two new loop-mediated amplification techniques. Quantitation of leptospiremia, detection in different specimen types, and the complementary roles played by molecular detection and microscopic agglutination testing will be discussed. Finally, a protocol for Leptospira strain subtyping using variable number tandem repeat targets and high-resolution melting will be described. Molecular diagnostics have an established role for the diagnosis of leptospirosis and provide an actionable diagnosis in the acute setting. The use of real-time reverse-transcription PCR for testing serum/plasma and cerebrospinal fluid, when available, may improve the detection of Leptospira without decreasing clinical specificity.
[Comparison of several methods for detecting anti-erythrocyte alloantibodies].
Bencomo, A A
1990-08-01
The efficacy of different methods for anti-red cell antibodies detection was assessed, variations being found in accordance with the specificity of the alloantibodies. The usefulness of enzyme tests in anti-Rh antibody detection was demonstrated, as well as that of low ionic strength saline solutions in detecting anti-Kell, anti-Duffy and anti-Kidd antibodies. Serum precipitation with 15% polyethyleneglycol 8000 previously to indirect antiglobulin test was found the most sensitive method, providing the best results in all the antibodies studied.
Satouchi, Miyako; Tanaka, Hiroshi; Yoshioka, Hiroshige; Shimokawaji, Tadasuke; Mizuno, Keiko; Takeda, Koji; Yoshino, Ichiro; Seto, Takashi; Kurata, Takayasu; Tashiro, Naoki; Hagiwara, Koichi
2017-09-01
Detection of epidermal growth factor receptor (EGFR) gene mutations is essential in deciding therapeutic strategy in non-small cell lung cancer (NSCLC) patients at initial diagnosis. Moreover, in EGFR mutation-positive (EGFRm) NSCLC patients, re-biopsy at disease progression to clarify resistance mechanisms is also important. However, collecting histology samples is often difficult because of inaccessibility and invasiveness. In some cases, only cytology samples can be collected, and studies have reported that cytology samples are appropriate for EGFR gene mutation testing. The cobas ® EGFR Mutation Test (Roche Molecular Systems Inc., Branchburg, New Jersey, USA) is approved as a companion diagnostic for osimertinib, a third-generation EGFR-tyrosine kinase inhibitor approved in Japan. However, it is not clear whether the EGFR T790M mutation can be detected in cytology samples using this test. The primary objective of this study was to assess concordance of EGFR T790M gene mutation detection between histology and matched cytology samples using the cobas ® EGFR Mutation Test. We conducted a multicenter, observational study in Japan. Overall, 41 EGFRm NSCLC patients who had both histology and cytology samples collected at the same time at re-biopsy and with the results of EGFR mutation test using histology samples were enrolled. The EGFR mutation status of both sample types was tested using the cobas ® EGFR Mutation Test and the concordance rates were calculated. The EGFR T790M mutation detection rate in histology and cytology samples was 42.5% and 37.5%, respectively. The overall percent agreement between the histology and cytology samples was 91.7%. These data demonstrate that the cobas ® EGFR Mutation Test can detect the EGFR T790M mutation in both cytology and histology samples. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.
Ultraviolet resonance Raman spectroscopy for the detection of cocaine in oral fluid
NASA Astrophysics Data System (ADS)
D'Elia, Valentina; Montalvo, Gemma; Ruiz, Carmen García; Ermolenkov, Vladimir V.; Ahmed, Yasmine; Lednev, Igor K.
2018-01-01
Detecting and quantifying cocaine in oral fluid is of significant importance for practical forensics. Up to date, mainly destructive methods or biochemical tests have been used, while spectroscopic methods were only applied to pretreated samples. In this work, the possibility of using resonance Raman spectroscopy to detect cocaine in oral fluid without pretreating samples was tested. It was found that ultraviolet resonance Raman spectroscopy with 239-nm excitation allows for the detection of cocaine in oral fluid at 10 μg/mL level. Further method development will be needed for reaching the practically useful levels of cocaine detection.
Sawamura, Kensuke; Hashimoto, Masahiko
2017-01-01
A fluorescence quenching assay based on a ligase detection reaction was developed for facile and rapid detection of point mutations present in a mixed population of non-variant DNA. If the test DNA carried a targeted mutation, then the two allele-specific primers were ligated to form a molecular beacon resulting in the expected fluorescence quenching signatures. Using this method, we successfully detected as low as 5% mutant DNA in a mixture of wild-type DNA (t test at 99% confidence level).
Cho, Jae Hoon; Suh, Jeffrey D; Kim, Jin Kook; Hong, Seok-Chan; Park, Il-Ho; Lee, Heung-Man
2014-01-01
Allergy test results can differ based on the method used. The most common tests include skin-prick testing (SPT) and in vitro tests to detect allergen-specific IgE. This study was designed to assess allergy test results using SPT, individual specific IgE tests, and a multiallergen IgE assay (multiple allergen simultaneous test) in patients with chronic rhinitis and controls. One hundred forty total patients were prospectively enrolled in the study, including 100 patients with chronic rhinitis and 40 control patients without atopy. All eligible patients underwent SPT, serum analysis using individual specific IgE test, and multiple allergen simultaneous test against 10 common allergens. Allergy test results were then compared to identify correlation and interest agreement. There was an 81-97% agreement between SPT and individual specific IgE test in allergen detection and an 80-98% agreement between SPT and multiple allergen simultaneous test. Individual specific IgE test and multiple allergen simultaneous test allergy detection prevalence was generally similar to SPT in patients with chronic rhinitis. All control patients had negative SPT (0/40), but low positive results were found with both individual specific IgE test (5-12.5%) and multiple allergen simultaneous test (2.5-7.5%) to some allergens, especially cockroach, Dermatophagoides farina, and ragweed. Agreement and correlation between individual specific IgE test and multiple allergen simultaneous test were good to excellent for a majority of tested allergens. This study shows good agreement and correlation between SPT with individual specific IgE test and multiple allergen simultaneous test on a majority of the tested allergens for patients with chronic rhinitis. Comparing the two in vitro tests, individual specific IgE test agrees with SPT better than multiple allergen simultaneous test.
Polyvalent heat-killed antigen for the diagnosis of infection with Legionella pneumophila.
Fallon, R J; Abraham, W H
1982-01-01
A polyvalent antigen composed of heat-killed agar-grown Legionella pneumophila serogroups 1-4 suspended in a suspension of yolk-sac from embryonated hens' eggs has been examined for use in the indirect fluorescent antibody test for Legionella infection. The serological response detected by monovalent antigen correlated well with that detected by polyvalent antigen. The use of polyvalent antigen forms a useful screening test for the detection of antibody to L pneumophila, but positive results must be confirmed by test using monovalent antigen. PMID:7042762
Eremkin, A V; Elagin, G D; Petchenkin, D V; Fomenkov, O O; Bogatcheva, N V; Kitmanov, A A; Kuklina, G V; Tikhvinskaya, O V
2016-03-01
The immune enzyme and immunochromatographic test-systems for detecting tularemia agent were developed on the basis of selected set of monoclonal antibodies having immunochemical activity to antigens Francisella tularensis. The evaluation of sensitivity and specificity of developed test-systems demonstrated that samples provided detection of strains of F. tularensis in concentration from 5.0 x 105 mkxcm-3 to 1.0 x 106 mkxcm-3 and gave no false positive results in analysis of heterologous microorganisms in concentration of 1.0 x 108 mkxcm-3.
Development of molecular tests for the detection of ILAR and latent viruses in fruit trees.
Roussel, S; Kummert, J; Dutrecq, O; Lepoivre, P; Jijakli, M H
2004-01-01
The detection throughout the year of latent and ILAR viruses in fruit tress by classical serological tests appear to be unreliable. We have developed RT-PCR tests for a reliable detection of latent and ILAR viruses in fruit trees. These assays were then simplified to allow the direct use of crude plant extracts instead of total RNA preparations, and the analyses of pooled samples. In this way, such RT-PCR protocols are suitable for a routine diagnosis of latent and ILAR viruses in fruit tree certification.
Colon cancer screening: which non-invasive filter tests?
Pox, Christian
2011-01-01
The following non-invasive stool tests for colorectal cancer (CRC) screening exist: guaiac or immunochemical fecal occult blood testing (FOBT), genetic stool tests and the M2-PK. Currently the most widely used tests are guaiac-based (gFOBT). Several randomized controlled trials have shown that gFOBT are able to achieve a reduction in CRC-related mortality. This reduction is achieved by detecting asymptomatic cancers at an early stage with a better prognosis. However, gFOBT have a low sensitivity for colorectal adenomas and are thus unlikely to be able to reduce the incidence of CRC. Furthermore, gFOBT are not specific for human blood and can be influenced by external factors. Immunochemical tests (iFOBT) only detect human blood in the stool. In two recent randomized studies from the Netherlands comparing guaiac and immunochemical tests in the asymptomatic population, iFOBT were found to detect more cancers than gFOBT. Furthermore, iFOBT were able to detect more advanced adenomas thus having the potential to be able to reduce the incidence of CRC as well as CRC-related mortality. In the recently released European CRC screening guidelines, iFOBT are considered the screening test of choice. Several questions remain however. It is currently unknown what the optimal cut-off value for an iFOBT to be considered positive should be and what the number of stool samples is that are required. Genetic stool tests detect mutations in stool that can be found in CRC. The original test testing for 21 genetic changes was found to be superior to gFOBT for the detection of cancers. However, the sensitivity was moderate (51.6%) and the sensitivity for advanced adenomas was low. In the meantime the test has been modified improving DNA extraction and reducing the number of mutations tested for as well as including a methylation marker. The efficacy of the modified test in the screening population is unknown. M2-PK is an isomer of the enzyme pyruvate kinase that is involved in glycolysis. Studies have found a good sensitivity for cancers, a low sensitivity for advanced adenomas with a specificity of around 80%. Further studies in the screening population are required. Copyright © 2011 S. Karger AG, Basel.
Visual performance on detection tasks with double-targets of the same and different difficulty.
Chan, Alan H S; Courtney, Alan J; Ma, C W
2002-10-20
This paper reports a study of measurement of horizontal visual sensitivity limits for 16 subjects in single-target and double-targets detection tasks. Two phases of tests were conducted in the double-targets task; targets of the same difficulty were tested in phase one while targets of different difficulty were tested in phase two. The range of sensitivity for the double-targets test was found to be smaller than that for single-target in both the same and different target difficulty cases. The presence of another target was found to affect performance to a marked degree. Interference effect of the difficult target on detection of the easy one was greater than that of the easy one on the detection of the difficult one. Performance decrement was noted when correct percentage detection was plotted against eccentricity of target in both the single-target and double-targets tests. Nevertheless, the non-significant correlation found between the performance for the two tasks demonstrated that it was impossible to predict quantitatively ability for detection of double targets from the data for single targets. This indicated probable problems in generalizing data for single target visual lobes to those for multiple targets. Also lobe area values obtained from measurements using a single-target task cannot be applied in a mathematical model for situations with multiple occurrences of targets.
Ahn, M. H.; Han, D.; Won, H. Y.; ...
2015-02-03
For better utilization of the ground-based microwave radiometer, it is important to detect the cloud presence in the measured data. Here, we introduce a simple and fast cloud detection algorithm by using the optical characteristics of the clouds in the infrared atmospheric window region. The new algorithm utilizes the brightness temperature (Tb) measured by an infrared radiometer installed on top of a microwave radiometer. The two-step algorithm consists of a spectral test followed by a temporal test. The measured Tb is first compared with a predicted clear-sky Tb obtained by an empirical formula as a function of surface air temperaturemore » and water vapor pressure. For the temporal test, the temporal variability of the measured Tb during one minute compares with a dynamic threshold value, representing the variability of clear-sky conditions. It is designated as cloud-free data only when both the spectral and temporal tests confirm cloud-free data. Overall, most of the thick and uniform clouds are successfully detected by the spectral test, while the broken and fast-varying clouds are detected by the temporal test. The algorithm is validated by comparison with the collocated ceilometer data for six months, from January to June 2013. The overall proportion of correctness is about 88.3% and the probability of detection is 90.8%, which are comparable with or better than those of previous similar approaches. Two thirds of discrepancies occur when the new algorithm detects clouds while the ceilometer does not, resulting in different values of the probability of detection with different cloud-base altitude, 93.8, 90.3, and 82.8% for low, mid, and high clouds, respectively. Finally, due to the characteristics of the spectral range, the new algorithm is found to be insensitive to the presence of inversion layers.« less
Improving the Space Surveillance Telescope's Performance Using Multi-Hypothesis Testing
NASA Astrophysics Data System (ADS)
Zingarelli, J. Chris; Pearce, Eric; Lambour, Richard; Blake, Travis; Peterson, Curtis J. R.; Cain, Stephen
2014-05-01
The Space Surveillance Telescope (SST) is a Defense Advanced Research Projects Agency program designed to detect objects in space like near Earth asteroids and space debris in the geosynchronous Earth orbit (GEO) belt. Binary hypothesis test (BHT) methods have historically been used to facilitate the detection of new objects in space. In this paper a multi-hypothesis detection strategy is introduced to improve the detection performance of SST. In this context, the multi-hypothesis testing (MHT) determines if an unresolvable point source is in either the center, a corner, or a side of a pixel in contrast to BHT, which only tests whether an object is in the pixel or not. The images recorded by SST are undersampled such as to cause aliasing, which degrades the performance of traditional detection schemes. The equations for the MHT are derived in terms of signal-to-noise ratio (S/N), which is computed by subtracting the background light level around the pixel being tested and dividing by the standard deviation of the noise. A new method for determining the local noise statistics that rejects outliers is introduced in combination with the MHT. An experiment using observations of a known GEO satellite are used to demonstrate the improved detection performance of the new algorithm over algorithms previously reported in the literature. The results show a significant improvement in the probability of detection by as much as 50% over existing algorithms. In addition to detection, the S/N results prove to be linearly related to the least-squares estimates of point source irradiance, thus improving photometric accuracy. The views expressed are those of the author and do not reflect the official policy or position of the Department of Defense or the U.S. Government.
Herman, Yael; Feine, Ilan; Gafny, Ron
2018-04-30
The precise and efficient detection of semen and saliva in sexual assault case-work items is a critical step in the forensic pipeline. The outcome of this stage may have a profound impact on identifying perpetrators as well as on the investigation process and the final outcome in court. Semen detection is usually based on the activity of acid phosphatase (AP), an enzyme found in high concentration in the seminal plasma. Amylase, an enzyme catalyzing starch hydrolysis is found in high concentrations in saliva and therefore is a useful target for its detection. To screen case-work items, both presumptive tests require transfer of biological material from the item to paper in a moisturized environment. Since semen and saliva may appear in the same item, it is required in some cases to perform the tests one after the other. This may reduce the chances of identifying all stains on the item and obtaining a DNA profile. In the present study, we applied the AP biochemical test on a Phadebas ® sheet, a commercial starch containing paper used to detect saliva. This approach was found to be sensitive enough to detect diluted semen (1:50) after performing the Phadebas ® press test. In addition, it enabled detection of adjacent saliva and semen stains and stains containing a semen-saliva mixture. Finally, a DNA profile was successfully obtained from the Phadebas ® sheets after semen detection, a useful feature if the original item is lost or damaged. Taken together, this method provides a practical, reliable and convenient tool for screening sexual assault items of evidence. Copyright © 2018 Elsevier B.V. All rights reserved.
Shariati, Laleh; Validi, Majid; Tabatabaiefar, Mohammad Amin; Karimi, Ali; Nafisi, Mohammad Reza
2010-12-01
Methicillin-resistant Staphylococcus aureus (MRSA) is a nosocomial pathogen. Our main objective was to compare oxacillin disk test, oxacillin E-test, and oxacillin agar screen for detection of methicillin resistance in S. aureus, using real-time PCR for mecA as the "gold standard" comparison assay. 196 S. aureus isolates were identified out of 284 Staphylococcus isolates. These isolates were screened for MRSA with several methods: disk diffusion, agar screen (6.0 μg/ml), oxacillin E-test, and real-time PCR for detection of mecA gene. Of the 196 S. aureus isolates tested, 96 isolates (49%) were mecA-positive and 100 isolates (51%) mecA-negative. All methods tested had a statistically significant agreement with real-time PCR. E-test was 100% sensitive and specific for mecA presence. The sensitivity and specificity of oxacillin agar screen method were 98 and 99%, respectively and sensitivity and specificity of oxacillin disk diffusion method were 95 and 93%, respectively. In the present study, oxacillin E-test is proposed as the best phenotypic method. For economic reasons, the oxacillin agar screen method (6.0 μg/ml), which is suitable for the detection of MRSA, is recommended due to its accuracy and low cost.
Streamlined, PCR-based testing for pfhrp2- and pfhrp3-negative Plasmodium falciparum.
Parr, Jonathan B; Anderson, Olivia; Juliano, Jonathan J; Meshnick, Steven R
2018-04-02
Rapid diagnostic tests (RDTs) that detect histidine-rich protein 2 (PfHRP2) are used throughout Africa for the diagnosis of Plasmodium falciparum malaria. However, recent reports indicate that parasites lacking the pfhrp2 and/or histidine-rich protein 3 (pfhrp3) genes, which produce antigens detected by these RDTs, are common in select regions of South America, Asia, and Africa. Proving the absence of a gene is challenging, and multiple PCR assays targeting these genes have been described. A detailed characterization and comparison of published assays is needed to facilitate robust and streamlined testing approaches. Among six pfhrp2 and pfhrp3 PCR assays tested, the lower limit of detection ranged from 0.01 pg/µL to 0.1 ng/µL of P. falciparum 3D7 strain DNA, or approximately 0.4-4000 parasite genomes/µL. By lowering the elongation temperature to 60 °C, a tenfold improvement in the limit of detection and/or darker bands for all exon 1 targets and for the first-round reaction of a single exon 2 target was achieved. Additionally, assays targeting exon 1 of either gene yielded spurious amplification of the paralogous gene. Using these data, an optimized testing algorithm for the detection of pfhrp2- and pfhrp3-negative P. falciparum is proposed. Surveillance of pfhrp2- and pfhrp3-negative P. falciparum requires careful laboratory workflows. PCR-based testing methods coupled with microscopy and/or antigen testing serve as useful tools to support policy development. Standardized approaches to the detection of pfhrp2- and pfhrp3-negative P. falciparum should inform efforts to define the impact of these parasites.
A new measure for the assessment of visual awareness in individuals with tunnel vision.
AlSaqr, Ali M; Dickinson, Chris M
2017-01-01
Individuals with a restricted peripheral visual field or tunnel vision (TV) have problems moving about and avoiding obstacles. Some individuals adapt better than others and some use assistive optical aids, so measurement of the visual field is not sufficient to describe their performance. In the present study, we developed a new clinical test called the 'Assessment of Visual Awareness (AVA)', which can be used to measure detection of peripheral targets. The participants were 20 patients with TV due to retinitis pigmentosa (PTV) and 50 normally sighted participants with simulated tunnel vision (STV) using goggles. In the AVA test, detection times were measured, when subjects searched for 24 individually presented, one degree targets, randomly positioned in a 60 degrees noise background. Head and eye movements were allowed and the presentation time was unlimited. The test validity was investigated by correlating the detection times with the 'percentage of preferred walking speed' (PPWS) and the 'number of collisions' on an indoor mobility course. In PTV and STV, the detection times had significant negative correlation with the field of view. The detection times had significant positive relations with target location. In the STV, the detection time was significantly negatively correlated with the PPWS and significantly positively correlated with the collisions score on the indoor mobility course. In the PTV, the relationship was not statistically significant. No significant difference in performance of STV was found when repeating the test one to two weeks later. The proposed AVA test was sensitive to the field of view and target location. The test is unique in design, quick, simple to deliver and both repeatable and valid. It could be a valuable tool to test different rehabilitation strategies in patients with TV. © 2016 Optometry Australia.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Braatz, Brett G.; Cumblidge, Stephen E.; Doctor, Steven R.
2012-12-31
The U.S. Nuclear Regulatory Commission has established the Program to Assess the Reliability of Emerging Nondestructive Techniques (PARENT) as a follow-on to the international cooperative Program for the Inspection of Nickel Alloy Components (PINC). The goal of PINC was to evaluate the capabilities of various nondestructive evaluation (NDE) techniques to detect and characterize surface-breaking primary water stress corrosion cracks in dissimilar-metal welds (DMW) in bottom-mounted instrumentation (BMI) penetrations and small-bore (≈400-mm diameter) piping components. A series of international blind round-robin tests were conducted by commercial and university inspection teams. Results from these tests showed that a combination of conventional andmore » phased-array ultrasound techniques provided the highest performance for flaw detection and depth sizing in dissimilar metal piping welds. The effective detection of flaws in BMIs by eddy current and ultrasound shows that it may be possible to reliably inspect these components in the field. The goal of PARENT is to continue the work begun in PINC and apply the lessons learned to a series of open and blind international round-robin tests that will be conducted on a new set of piping components including large-bore (≈900-mm diameter) DMWs, small-bore DMWs, and BMIs. Open round-robin testing will engage universities and industry worldwide to investigate the reliability of emerging NDE techniques to detect and accurately size flaws having a wide range of lengths, depths, orientations, and locations. Blind round-robin testing will invite testing organizations worldwide, whose inspectors and procedures are certified by the standards for the nuclear industry in their respective countries, to investigate the ability of established NDE techniques to detect and size flaws whose characteristics range from easy to very difficult to detect and size. This paper presents highlights of PINC and reports on the plans and progress for PARENT round-robin tests.« less
NASA Astrophysics Data System (ADS)
Wallace, T. C.
2013-12-01
In the summer of 1958 scientists from the Soviet block and the US allies met in Geneva to discuss what it would take to monitor a forerunner to a Comprehensive Test Ban Treaty at the 'Conference of Experts to Study the Possibility of Detecting Violations of a Possible Agreement on Suspension of Nuclear Tests'. Although armed with a limited resume of observations, the conference recommended a multi-phenomenology approach (air sampling, acoustics, seismic and electromagnetic) deployed it a network of 170 sites scattered across the Northern Hemisphere, and hypothesized a detection threshold of 1kt for atmospheric tests and 5kt for underground explosions. The conference recommendations spurred vigorous debate, with strong disagreement with the stated detection hypothesis. Nevertheless, the technical challenges posed lead to a very focused effort to improve facilities, methodologies and, most importantly, research and development on event detection, location and identification. In the ensuing 50 years the various challenges arose and were eventually 'solved'; these included quantifying yield determination to enter a Limited Threshold Test Ban, monitoring broad areas of emerging nuclear nations, and after the mid-1990s lowering the global detection threshold to sub-kiloton levels for underground tests. Today there is both an international monitoring regime (ie, the International Monitoring System, or IMS) and a group of countries that have their own national technical means (NTM). The challenges for the international regime are evolving; the IMS has established itself as a very credible monitoring system, but the demand of a CTBT to detect and identify a 'nuclear test' of diminished size (zero yield) poses new technical hurdles. These include signal processing and understanding limits of resolution, location accuracy, integration of heterogeneous data, and accurately characterizing anomalous events. It is possible to extrapolate past technical advances to predict what should be available by 2020; detection of coupled explosions to 100s of tons for all continental areas, as well as a probabilistic assessment of event identification.
Senkomago, V; Des Marais, A C; Rahangdale, L; Vibat, C R T; Erlander, M G; Smith, J S
2016-01-01
Urine testing for high-risk human papillomavirus (HR-HPV) detection could provide a non-invasive, simple method for cervical cancer screening. We examined whether HR-HPV detection is affected by urine collection time, portion of urine stream, or urine fraction tested, and assessed the performance of HR-HPV testing in urine for detection of cervical intraepithelial neoplasia grade II or worse (CIN2+). A total of 37 female colposcopy clinic attendees, ≥ 30 years, provided three urine samples: "first void" urine collected at home, and "initial stream" and "mid-stream" urine samples collected at the clinic later in the day. Self- and physician-collected brush specimens were obtained at the same clinic visit. Colposcopy was performed and directed biopsies obtained if clinically indicated. For each urine sample, HR-HPV DNA testing was conducted for unfractionated, pellet, and supernatant fractions using the Trovagene test. HR-HPV mRNA testing was performed on brush specimens using the Aptima HPV assay. HR-HPV prevalence was similar in unfractionated and pellet fractions of all urine samples. For supernatant urine fractions, HR-HPV prevalence appeared lower in mid-stream urine (56.8%[40.8-72.7%]) than in initial stream urine (75.7%[61.9-89.5%]). Sensitivity of CIN2+ detection was identical for initial stream urine and physician-collected cervical specimen (89.9%[95%CI=62.7-99.6%]), and similar to self-collected vaginal specimen (79.1%[48.1-96.6%]). This is among the first studies to compare methodologies for collection and processing of urine for HR-HPV detection. HR-HPV prevalence was similar in first void and initial stream urine, and was highly sensitive for CIN2+ detection. Additional research in a larger and general screening population is needed. Copyright © 2015 Elsevier B.V. All rights reserved.
Gas Transport and Detection Following Underground Nuclear Explosions
NASA Astrophysics Data System (ADS)
Carrigan, C. R.; Sun, Y.; Wagoner, J. L.; Zucca, J. J.
2011-12-01
Some extremely rare radioactive noble gases are by-products of underground nuclear explosions, and the detection of significant levels of these gases (e.g., Xe-133 and Ar-37) at the surface is a very strong indicator of the occurrence of an underground nuclear event. Because of their uniqueness, such noble gas signatures can be confirmatory of the nuclear nature of an event while signatures from other important detection methods, such as anomalous seismicity, are generally not. As a result, noble gas detection at a suspected underground nuclear test site is considered to be the most important technique available to inspectors operating under the On-Site-Inspection protocol of the Comprehensive Nuclear Test Ban Treaty. A one-kiloton chemical underground explosion, the Non-Proliferation Experiment (NPE), was carried out at the Nevada Test Site in 1993 and represented the first On-Site-Inspection oriented test of subsurface gas transport with subsequent detection at the surface using soil gas sampling methods. A major conclusion of the experiment was that noble gases from underground nuclear tests have a good possibility of being detected even if the test is well contained. From this experiment and from computer simulations, we have also learned significant lessons about the modes of gas transport to the surface and the importance of careful subsurface sampling to optimize the detected noble gas signature. Understanding transport and sampling processes for a very wide range of geologic and testing scenarios presents significant challenges that we are currently addressing using sensitivity studies, which we attempt to verify using experiments such as the NPE and a new subsurface gas migration experiment that is now being undertaken at the National Center for Nuclear Security. This work performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344.
Detection of Salmonella enterica Serovar Typhimurium by Using a Rapid, Array-Based Immunosensor
Taitt, Chris Rowe; Shubin, Yura S.; Angel, Roselina; Ligler, Frances S.
2004-01-01
The multianalyte array biosensor (MAAB) is a rapid analysis instrument capable of detecting multiple analytes simultaneously. Rapid (15-min), single-analyte sandwich immunoassays were developed for the detection of Salmonella enterica serovar Typhimurium, with a detection limit of 8 × 104 CFU/ml; the limit of detection was improved 10-fold by lengthening the assay protocol to 1 h. S. enterica serovar Typhimurium was also detected in the following spiked foodstuffs, with minimal sample preparation: sausage, cantaloupe, whole liquid egg, alfalfa sprouts, and chicken carcass rinse. Cross-reactivity tests were performed with Escherichia coli and Campylobacter jejuni. To determine whether the MAAB has potential as a screening tool for the diagnosis of asymptomatic Salmonella infection of poultry, chicken excretal samples from a private, noncommercial farm and from university poultry facilities were tested. While the private farm excreta gave rise to signals significantly above the buffer blanks, none of the university samples tested positive for S. enterica serovar Typhimurium without spiking; dose-response curves of spiked excretal samples from university-raised poultry gave limits of detection of 8 × 103 CFU/g. PMID:14711637
Research on Vehicle-Based Driver Status/Performance Monitoring, Part III
DOT National Transportation Integrated Search
1996-09-01
A driver drowsiness detection/alarm/countermeasures system was specified, tested and evaluated, resulting in the development of revised algorithms for the detection of driver drowsiness. Previous algorithms were examined in a test and evaluation stud...
ETV Tech Brief: Rapid Fungi and Bacteria Detection Technologies
Technical brief that summarizes the results for Mycometer, Inc. Mycometer®-test and Bactiquant®-test, which are rapid detection technologies for fungi and bacteria. The brief summarizes the results of the verification report and statement.
Research On Vehicle-Based Driver Status/Performance Monitoring, Part I
DOT National Transportation Integrated Search
1996-09-01
A driver drowsiness detection/alarm/countermeasures system was specified, tested and evaluated, resulting in the development of revised algorithms for the detection of driver drowsiness. Previous algorithms were examined in a test and evaluation stud...
PCR-Based Method for Detecting Viral Penetration of Medical Exam Gloves
Broyles, John M.; O'Connell, Kevin P.; Korniewicz, Denise M.
2002-01-01
The test approved by the U.S. Food and Drug Administration for assessment of the barrier quality of medical exam gloves includes visual inspection and a water leak test. Neither method tests directly the ability of gloves to prevent penetration by microorganisms. Methods that use microorganisms (viruses and bacteria) to test gloves have been developed but require classical culturing of the organism to detect it. We have developed a PCR assay for bacteriophage φX174 that allows the rapid detection of penetration of gloves by this virus. The method is suitable for use with both latex and synthetic gloves. The presence of glove powder on either latex or synthetic gloves had no effect on the ability of the PCR assay to detect bacteriophage DNA. The assay is rapid, sensitive, and inexpensive; requires only small sample volumes; and can be automated. PMID:12149320
LIBS and LIFS for rapid detection of Rb traces in blood
NASA Astrophysics Data System (ADS)
Al-Jeffery, Mohammad O.; Telle, Helmut H.
2002-05-01
Tests that can quickly and efficiently detect traces of illegal performance enhancing drugs are becoming essential. Certain performance enhancing drugs lead to an increase in the count of red blood cells. The proportion of blood made up of red cells is normally around 42 percent. At least 90 percent of Rubidium measured in whole blood is located in the red blood cells. If Rubidium Chloride (RbCl) is given to an athlete around 30 minutes before competing and a sample of their blood (a drop on a filter) was subsequently tested for Rubidium content, the test will give a direct indication of the red blood cell count. In this contribution, we describe an efficient and fast test based on spectroscopic techniques that can be used to detect trace levels of Rubidium. Our experiments employed Rubidium nitride (RbNO3) and trace levels down to 0.3 percent were successfully detected.
Mauk, Michael G.; Song, Jinzhao; Liu, Changchun; Bau, Haim H.
2018-01-01
Designs and applications of microfluidics-based devices for molecular diagnostics (Nucleic Acid Amplification Tests, NAATs) in infectious disease testing are reviewed, with emphasis on minimally instrumented, point-of-care (POC) tests for resource-limited settings. Microfluidic cartridges (‘chips’) that combine solid-phase nucleic acid extraction; isothermal enzymatic nucleic acid amplification; pre-stored, paraffin-encapsulated lyophilized reagents; and real-time or endpoint optical detection are described. These chips can be used with a companion module for separating plasma from blood through a combined sedimentation-filtration effect. Three reporter types: Fluorescence, colorimetric dyes, and bioluminescence; and a new paradigm for end-point detection based on a diffusion-reaction column are compared. Multiplexing (parallel amplification and detection of multiple targets) is demonstrated. Low-cost detection and added functionality (data analysis, control, communication) can be realized using a cellphone platform with the chip. Some related and similar-purposed approaches by others are surveyed. PMID:29495424
Testing pigeon memory in a change detection task.
Wright, Anthony A; Katz, Jeffrey S; Magnotti, John; Elmore, L Caitlin; Babb, Stephanie; Alwin, Sarah
2010-04-01
Six pigeons were trained in a change detection task with four colors. They were shown two colored circles on a sample array, followed by a test array with the color of one circle changed. The pigeons learned to choose the changed color and transferred their performance to four unfamiliar colors, suggesting that they had learned a generalized concept of color change. They also transferred performance to test delays several times their 50-msec training delay without prior delay training. The accurate delay performance of several seconds suggests that their change detection was memory based, as opposed to a perceptual attentional capture process. These experiments are the first to show that an animal species (pigeons, in this case) can learn a change detection task identical to ones used to test human memory, thereby providing the possibility of directly comparing short-term memory processing across species.
Huo, Ya-Yun; Li, Gui-Fen; Qiu, Yan-Hong; Li, Wei-Min; Zhang, Yong-Jiang
2017-11-23
Prunus necrotic ringspot virus (PNRSV) is one of the most devastating viruses to Prunus spp. In this study, we developed a diagnostic system RT-CPA-NATSC, wherein reverse transcription-cross-priming amplification (RT-CPA) is coupled with nucleic acid test strip cassette (NATSC), a vertical flow (VF) visualization, for PNRSV detection. The RT-CPA-NATSC assay targets the encoding gene of the PNRSV coat protein with a limit of detection of 72 copies per reaction and no cross-reaction with the known Prunus pathogenic viruses and viroids, demonstrating high sensitivity and specificity. The reaction is performed on 60 °C and can be completed less than 90 min with the prepared template RNA. Field sample test confirmed the reliability of RT-CPA-NATSC, indicating the potential application of this simple and rapid detection method in routine test of PNRSV.
Testing Eurasian wild boar piglets for serum antibodies against Mycobacterium bovis.
Che' Amat, A; González-Barrio, D; Ortiz, J A; Díez-Delgado, I; Boadella, M; Barasona, J A; Bezos, J; Romero, B; Armenteros, J A; Lyashchenko, K P; Venteo, A; Rueda, P; Gortázar, C
2015-09-01
Animal tuberculosis (TB) caused by infection with Mycobacterium bovis and closely related members of the M. tuberculosis complex (MTC), is often reported in the Eurasian wild boar (Sus scrofa). Tests detecting antibodies against MTC antigens are valuable tools for TB monitoring and control in suids. However, only limited knowledge exists on serology test performance in 2-6 month-old piglets. In this age-class, recent infections might cause lower antibody levels and lower test sensitivity. We examined 126 wild boar piglets from a TB-endemic site using 6 antibody detection tests in order to assess test performance. Bacterial culture (n=53) yielded a M. bovis infection prevalence of 33.9%, while serum antibody prevalence estimated by different tests ranged from 19% to 38%, reaching sensitivities between 15.4% and 46.2% for plate ELISAs and between 61.5% and 69.2% for rapid immunochromatographic tests based on dual path platform (DPP) technology. The Cohen kappa coefficient of agreement between DPP WTB (Wildlife TB) assay and culture results was moderate (0.45) and all other serological tests used had poor to fair agreements. This survey revealed the ability of several tests for detecting serum antibodies against the MTC antigens in 2-6 month-old naturally infected wild boar piglets. The best performance was demonstrated for DPP tests. The results confirmed our initial hypothesis of a lower sensitivity of serology for detecting M. bovis-infected piglets, as compared to older wild boar. Certain tests, notably the rapid animal-side tests, can contribute to TB control strategies by enabling the setup of test and cull schemes or improving pre-movement testing. However, sub-optimal test performance in piglets as compared to that in older wild boar should be taken into account. Copyright © 2015 Elsevier B.V. All rights reserved.
Ng, Yit Han; Subramaniam, Vellayan; Lau, Yee Ling
2015-11-30
Sarcocystosis in meat-producing animals is a major cause of reduced productivity in many countries, especially those that rely on agriculture. Although several diagnostic methods are available to detect sarcocystosis, many are too time-consuming for routine use in abattoirs and meat inspection centers, where large numbers of samples need to be tested. This study aimed to compare the sensitivity of the methylene blue tissue preparation, unstained tissue preparation and nested PCR in the detection of sarcocysts in tissue samples. Approximately three-fold more sarcocysts were detected in methylene blue-stained tissue compared to unstained controls (McNemar's test: P<0.01). Test sensitivity was comparable to that of the gold standard for sarcocyst detection, nested polymerase chain reaction. These results suggest that methylene blue can be used in tissue compression as a rapid, safe, and inexpensive technique for the detection of ruminant sarcocystosis in abattoirs. Copyright © 2015 Elsevier B.V. All rights reserved.
Zhou, Jie; Liao, Yu-xue; Chen, Zhong; Li, Yu-chun; Gao, Lu-Lu; Chen, Yi-xiong; Cai, Lian-gong; Chen, Qing; Yu, Shou-yi
2008-05-01
To develop an simple and sensitive method for detecting anti-coronavirus IgG antibodies in bat sera based on enzyme-linked immunosorbent assay (ELISA). A commercial ELISA kit for detecting SARS-CoV antibody was modified for detecting coronavirus antibodies in bat serum samples. The second antibody in the kit was replaced with horseradish peroxidase-conjugated protein-A (HRP-SPA) based on the characteristics of binding between Staphylococcus aureus protein A (SPA) and mammal IgG Fc fragment. The sera of 55 fulvous fruit bats (Rousettus dasymallus) were tested using the SPA-ELISA. The test results of the positive and negative controls in the kit and the serum samples from convalescent ;patient were consistent with expectation. Coronavirus antibody was detected in 2 out of the 55 bat serum samples. Serum neutralization test confirmed the validity of the SPA-ELISA method. This SPA-ELISA method is applicable for detecting coronavirus antibody in bat sera.
Woo, Patrick C Y; Lau, Susanna K P; Chen, Yixin; Wong, Emily Y M; Chan, Kwok-Hung; Chen, Honglin; Zhang, Libiao; Xia, Ningshao; Yuen, Kwok-Yung
2018-03-07
Recently, we developed a monoclonal antibody-based rapid nucleocapsid protein detection assay for diagnosis of MERS coronavirus (MERS-CoV) in humans and dromedary camels. In this study, we examined the usefulness of this assay to detect other lineage C betacoronaviruses closely related to MERS-CoV in bats. The rapid MERS-CoV nucleocapsid protein detection assay was tested positive in 24 (88.9%) of 27 Tylonycteris bat CoV HKU4 (Ty-BatCoV-HKU4) RNA-positive alimentary samples of Tylonycteris pachypus and 4 (19.0%) of 21 Pipistrellus bat CoV HKU5 (Pi-BatCoV-HKU5) RNA-positive alimentary samples of Pipistrellus abramus. There was significantly more Ty-BatCoV-HKU4 RNA-positive alimentary samples than Pi-BatCoV-HKU5 RNA-positive alimentary samples that were tested positive by the rapid MERS-CoV nucleocapsid protein detection assay (P < 0.001 by Chi-square test). The rapid assay was tested negative in all 51 alimentary samples RNA-positive for alphacoronaviruses (Rhinolophus bat CoV HKU2, Myotis bat CoV HKU6, Miniopterus bat CoV HKU8 and Hipposideros batCoV HKU10) and 32 alimentary samples positive for lineage B (SARS-related Rhinolophus bat CoV HKU3) and lineage D (Rousettus bat CoV HKU9) betacoronaviruses. No significant difference was observed between the viral loads of Ty-BatCoV-HKU4/Pi-BatCoV-HKU5 RNA-positive alimentary samples that were tested positive and negative by the rapid test (Mann-Witney U test). The rapid MERS-CoV nucleocapsid protein detection assay is able to rapidly detect lineage C betacoronaviruses in bats. It detected significantly more Ty-BatCoV-HKU4 than Pi-BatCoV-HKU5 because MERS-CoV is more closely related to Ty-BatCoV-HKU4 than Pi-BatCoV-HKU5. This assay will facilitate rapid on-site mass screening of animal samples for ancestors of MERS-CoV and tracking transmission in the related bat species.
Portable Microleak-Detection System
NASA Technical Reports Server (NTRS)
Rivers, H. Kevin; Sikora, Joseph G.; Sankaran, Sankara N.
2007-01-01
The figure schematically depicts a portable microleak-detection system that has been built especially for use in testing hydrogen tanks made of polymer-matrix composite materials. (As used here, microleak signifies a leak that is too small to be detectable by the simple soap-bubble technique.) The system can also be used to test for microleaks in tanks that are made of other materials and that contain gases other than hydrogen. Results of calibration tests have shown that measurement errors are less than 10 percent for leak rates ranging from 0.3 to 200 cm3/min. Like some other microleak-detection systems, this system includes a vacuum pump and associated plumbing for sampling the leaking gas, and a mass spectrometer for analyzing the molecular constituents of the gas. The system includes a flexible vacuum chamber that can be attached to the outer surface of a tank or other object of interest that is to be tested for leakage (hereafter denoted, simply, the test object). The gas used in a test can be the gas or vapor (e.g., hydrogen in the original application) to be contained by the test object. Alternatively, following common practice in leak testing, helium can be used as a test gas. In either case, the mass spectrometer can be used to verify that the gas measured by the system is the test gas rather than a different gas and, hence, that the leak is indeed from the test object.
Built-in-test by signature inspection (bitsi)
Bergeson, Gary C.; Morneau, Richard A.
1991-01-01
A system and method for fault detection for electronic circuits. A stimulus generator sends a signal to the input of the circuit under test. Signature inspection logic compares the resultant signal from test nodes on the circuit to an expected signal. If the signals do not match, the signature inspection logic sends a signal to the control logic for indication of fault detection in the circuit. A data input multiplexer between the test nodes of the circuit under test and the signature inspection logic can provide for identification of the specific node at fault by the signature inspection logic. Control logic responsive to the signature inspection logic conveys information about fault detection for use in determining the condition of the circuit. When used in conjunction with a system test controller, the built-in test by signature inspection system and method can be used to poll a plurality of circuits automatically and continuous for faults and record the results of such polling in the system test controller.
ERIC Educational Resources Information Center
Veeser, Peggy Ingram; Smith, Phillip Karl; Handy, Barry; Martin, Sharon R.
2007-01-01
Detecting and managing "Mycobacterium tuberculosis" (TB) infection in a health-science center population is a clinical dilemma. Tuberculin skin tests are still the preferred method for detecting present or past infection of TB. The authors discuss the performance of whole blood interferon gamma release assay test commercially known as…
Applications of Logic Coverage Criteria and Logic Mutation to Software Testing
ERIC Educational Resources Information Center
Kaminski, Garrett K.
2011-01-01
Logic is an important component of software. Thus, software logic testing has enjoyed significant research over a period of decades, with renewed interest in the last several years. One approach to detecting logic faults is to create and execute tests that satisfy logic coverage criteria. Another approach to detecting faults is to perform mutation…
Lin, Li-Rong; Fu, Zuo-Gen; Dan, Bing; Jing, Guang-Jun; Tong, Man-li; Chen, De-Teng; Yu, Yang; Zhang, Chang-Gong; Yang, Tian-Ci; Zhang, Zhong-Ying
2010-11-01
Syphilis remains a worldwide public health problem; it is necessary to develop a new diagnostic approach that is easier and faster than conventional tests. Here, we report a new testing method named colloidal gold-immunochromatography assay (GICA) to detect syphilis instead of fluorescent treponemal antibody-absorption (FTA-Abs). Syphilis-specific immunoglobulin G (IgG) antibody was detected with GICA established on syphilis-specific recombinant proteins, TPN17 and TPN47. FTA-Abs Treponema pallidum (TP)-IgG was set as the gold standard. A GICA test was performed to detect the serum of 14 967 subjects who took a serologic test for syphilis at the Xiamen Center of Clinical Laboratory, Fujian, China, from March 2009 to February 2010, among which 1326 cases were diagnosed as syphilitic. The results showed that the sensitivity, specificity, and positive predictive value were 99.38% (1279/1287), 99.96% (12,975/12,980), and 99.61% (1279/1284), respectively. The positive rate between the 2 test methods had no significant difference (χ(2) = 0.003, P > 0.05). Detection on 500 interference specimens indicated that the biologic false-positive rate of the GICA test was extremely low and free from other biologic and chemical factors. The characteristics of GICA TP-IgG correspond to that of FTA-Abs TP-IgG (EUROIMMUN Medizinische Labordiagnostika, Germany). The GICA test is convenient, fast, and inexpensive, and it can be used both as a confirmatory test and a screening indicator, instead of FTA-Abs TP-IgG. Copyright © 2010 Elsevier Inc. All rights reserved.
Szabó, I; Scherer, K; Roesler, U; Appel, B; Nöckler, K; Hensel, A
2008-05-10
The most frequently isolated Salmonella serotype from pork in Germany is S. typhimurium, especially phagetype DT 104. The monitoring programs on Salmonella in swine are based on enzyme-linked immunoadsorbent assay (ELISA) detecting antibodies in serum or meat juice. These serological results are used to classify swine herds in three categories to assess the hygienic status of farm regarding Salmonella infection in pigs. The object of this study was the comparative evaluation of four indirect Salmonella ELISA tests approved in Germany to detect Salmonella typhimurium infection of swine. Three tests (A-C) are based on LPS-antigen and directed against specific IgG-antibodies. The fourth test (D) bases on a whole-cell-lysate antigen and discriminates between Salmonella specific IgA-, IgM- and IgG-antibodies. In a longitudinal study sixteen 6 weeks old weaning pigs were orally infected with S. typhimurium DT 104. During an observation period of 138d clinical and bacteriological parameters were monitored and serum samples obtained at regular intervals as well as meat juice samples taken at slaughter were examined by the respective ELISA systems. Study results reveal that all tested ELISA systems are able to detect S. typhimurium infection in pigs in both sample matrices, blood serum and meat juice whereas test D showed the highest sensitivity to detect Salmonella antibodies in pigs. The sensitivity to detect Salmonella antibodies varied between tests A and C according to the used cut-off (test specific cut-off vs. recommended surveillance cut-off) resulting in a change of seroprevalence and hence may influence the Salmonella status of the farm.
Webb, Joanne L; Creamer, Jonathan I; Quickenden, Terence I
2006-01-01
Presumptive blood detection tests are used by forensic investigators to detect trace amounts of blood or to investigate suspicious stains. Through the years, a number of articles have been published on the popular techniques of the day. However, there is no single paper that critiques and compares the five most common presumptive blood detection tests currently in use: luminol, phenolphthalein (Kastle-Meyer), leucomalachite green, Hemastix and the forensic light source. The present authors aimed to compare the above techniques with regard to their sensitivity, ease of use and safety. The luminol test was determined to be the most sensitive of the techniques, while Hemastix is a suitable alternative when the luminol test is not appropriate. Copyright 2006 John Wiley & Sons, Ltd.
Banada, Padmapriya P; Deshpande, Srinidhi; Chakravorty, Soumitesh; Russo, Riccardo; Occi, James; Meister, Gabriel; Jones, Kelly J; Gelhaus, Carl H; Valderas, Michelle W; Jones, Martin; Connell, Nancy; Alland, David
2017-01-01
Francisella tularensis is a potential bioterrorism agent that is highly infectious at very low doses. Diagnosis of tularemia by blood culture and nucleic acid-based diagnostic tests is insufficiently sensitive. Here, we demonstrate a highly sensitive F. tularensis assay that incorporates sample processing and detection into a single cartridge suitable for point-of-care detection. The assay limit of detection (LOD) and dynamic range were determined in a filter-based cartridge run on the GeneXpert system. F. tularensis DNA in buffer or CFU of F. tularensis was spiked into human or macaque blood. To simulate detection in human disease, the assay was tested on blood drawn from macaques infected with F. tularensis Schu S4 at daily intervals. Assay detection was compared to that with a conventional quantitative PCR (qPCR) assay and blood culture. The assay LOD was 0.1 genome equivalents (GE) per reaction and 10 CFU/ml F. tularensis in both human and macaque blood. In infected macaques, the assay detected F. tularensis on days 1 to 4 postinfection in 21%, 17%, 60%, and 83% of macaques, respectively, compared to conventional qPCR positivity rates of 0%, 0%, 30%, and 100% and CFU detection of blood culture at 0%, 0%, 0%, and 10% positive, respectively. Assay specificity was 100%. The new cartridge-based assay can rapidly detect F. tularensis in bloodstream infections directly in whole blood at the early stages of infection with a sensitivity that is superior to that of other methods. The simplicity of the automated testing procedures may make this test suitable for rapid point-of-care detection. Copyright © 2016 American Society for Microbiology.
Metamorphic Testing for Cybersecurity.
Chen, Tsong Yueh; Kuo, Fei-Ching; Ma, Wenjuan; Susilo, Willy; Towey, Dave; Voas, Jeffrey; Zhou, Zhi Quan
2016-06-01
Testing is a major approach for the detection of software defects, including vulnerabilities in security features. This article introduces metamorphic testing (MT), a relatively new testing method, and discusses how the new perspective of MT can help to conduct negative testing as well as to alleviate the oracle problem in the testing of security-related functionality and behavior. As demonstrated by the effectiveness of MT in detecting previously unknown bugs in real-world critical applications such as compilers and code obfuscators, we conclude that software testing of security-related features should be conducted from diverse perspectives in order to achieve greater cybersecurity.
Metamorphic Testing for Cybersecurity
Chen, Tsong Yueh; Kuo, Fei-Ching; Ma, Wenjuan; Susilo, Willy; Towey, Dave; Voas, Jeffrey
2016-01-01
Testing is a major approach for the detection of software defects, including vulnerabilities in security features. This article introduces metamorphic testing (MT), a relatively new testing method, and discusses how the new perspective of MT can help to conduct negative testing as well as to alleviate the oracle problem in the testing of security-related functionality and behavior. As demonstrated by the effectiveness of MT in detecting previously unknown bugs in real-world critical applications such as compilers and code obfuscators, we conclude that software testing of security-related features should be conducted from diverse perspectives in order to achieve greater cybersecurity. PMID:27559196
Search by photo methodology for signature properties assessment by human observers
NASA Astrophysics Data System (ADS)
Selj, Gorm K.; Heinrich, Daniela H.
2015-05-01
Reliable, low-cost and simple methods for assessment of signature properties for military purposes are very important. In this paper we present such an approach that uses human observers in a search by photo assessment of signature properties of generic test targets. The method was carried out by logging a large number of detection times of targets recorded in relevant terrain backgrounds. The detection times were harvested by using human observers searching for targets in scene images shown by a high definition pc screen. All targets were identically located in each "search image", allowing relative comparisons (and not just rank by order) of targets. To avoid biased detections, each observer only searched for one target per scene. Statistical analyses were carried out for the detection times data. Analysis of variance was chosen if detection times distribution associated with all targets satisfied normality, and non-parametric tests, such as Wilcoxon's rank test, if otherwise. The new methodology allows assessment of signature properties in a reproducible, rapid and reliable setting. Such assessments are very complex as they must sort out what is of relevance in a signature test, but not loose information of value. We believe that choosing detection times as the primary variable for a comparison of signature properties, allows a careful and necessary inspection of observer data as the variable is continuous rather than discrete. Our method thus stands in opposition to approaches based on detections by subsequent, stepwise reductions in distance to target, or based on probability of detection.
Rapid detection of multidrug resistant Gram-negative bacilli by Cica-Beta-Test strips.
Lavigne, J-P; Pfeiffer, C; Vidal, L; Sotto, A
2011-02-01
This study aimed to evaluate the sensitivity and specificity of a new system (Cica-Beta-Test, Kanto Chemical, Japan) for rapid detection of AmpC-derepressed, extended-spectrum β-lactamases (ESβL) and metallo-β-lactamases (MβL). Two hundred Multi-Drug Resistant (MDR)-Gram-negative bacilli were studied: 170 Enterobacteriaceae and 30 Gram-negative non-fermentative bacteria. One hundred and eighteen strains produced an ESβL, seven MβL and 75 derepressed cephalosporinases. One drop of substrate was dispensed onto the filter pad of the Cica-Beta-Test strip. The bacterial colonies were spread on the filter pad of strip. The reading was performed after 2 to 15 min: turning chromogenic indicated the positive test. Three tests were used: Cica-Beta I for detection of MDR bacteria; Cica-Beta MβL for detection of MβL-producing bacteria and Cica-Beta CVA, which distinguish ESβL and AmpC-derepressed producers. Results were compared with molecular assays. Cica-Beta-Test I has detected 194 MDR (sensitivity 97%), Cica-Beta-Test MβL has shown the presence of six MβL tested (sensitivity 85.7%). Five strains were non-MβL false positive (specificity 97.3%). Cica-Beta-Test CVA allowed the differentiation of ESβL-producing strains (109/115) and AmpC-derepressed strains (56/67) (sensitivity 94.8%, specificity 83.8%). Because of their epidemic nature, the MDR strains are screened and require strict hygienic measures patients. The simultaneous use of three strips can quickly determine the presence of MDR including ESβL and MβL. Rapid screening of MDR avoids transmission and limits the use of broad-spectrum antibiotics. Copyright © 2010 Elsevier Masson SAS. All rights reserved.
Detecting Behavioral Deficits in Rats After Traumatic Brain Injury
Parsley, Margaret A.; Guptarak, Jutatip; Spratt, Heidi; Sell, Stacy L.
2018-01-01
With the increasing incidence of traumatic brain injury (TBI) in both civilian and military populations, TBI is now considered a chronic disease; however, few studies have investigated the long-term effects of injury in rodent models of TBI. Shown here are behavioral measures that are well-established in TBI research for times early after injury, such as two weeks, until two months. Some of these methods have previously been used at later times after injury, up to one year, but by very few laboratories. The methods demonstrated here are a short neurological assessment to test reflexes, a Beam-Balance to test balance, a Beam-Walk to test balance and motor coordination, and a working memory version of the Morris water maze that can be sensitive to deficits in reference memory. Male rats were handled and pre-trained to neurological, balance, and motor coordination tests prior to receiving parasagittal fluid percussion injury (FPI) or sham injury. Rats can be tested on the short neurological assessment (neuroscore), the beam-balance, and the Beam-Walk multiple times, while testing on the water maze can only be done once. This difference is because rats can remember the task, thus confounding the results if repeated testing is attempted in the same animal. When testing from one to three days after injury, significant differences are detected in all three non-cognitive tasks. However, differences in the Beam-Walk task were not detectable at later time points (after 3 months). Deficits were detected at 3 months in the Beam-Balance and at 6 months in the neuroscore. Deficits in working memory were detected out to 12 months after injury, and a deficit in a reference memory first appeared at 12 months. Thus, standard behavioral tests can be useful measures of persistent behavioral deficits after FPI. PMID:29443022
Burgos, Joaquin; Hernández-Losa, Javier; Landolfi, Stefania; Guelar, Ana; Dinares, MªCarmen; Villar, Judith; Navarro, Jordi; Ribera, Esteve; Falcó, Vicenç; Curran, Adria
2017-10-23
To assess the oncogenic human papillomavirus (HPV) determination and the cotesting HPV and anal cytology value to detect high-grade anal intraepithelial neoplasia (HGAIN) in a cohort of HIV-MSM. Prospective study of HIV-infected MSM who underwent screening for anal dysplasia. Screening program includes anal cytology, HPV testing, and high-resolution anoscopy (HRA) at each visit. Histological samples were obtained if suspicious lesions were revealed by HRA. Sensitivity and specificity of the different tests were calculated by using histological results of HRA-guided biopsy as the reference test for HGAIN diagnosis. From May 2009 to August 2016, 692 HIV-infected MSM underwent 1827 anal cytologies, 1841 HRA examinations, and 1607 HPV testing. At first screening visit, anal cytology results were abnormal in 418 (60.4%) of 692 patients, and oncogenic HPV genotypes were found in 482 (79.5%) of 606 patients. Anal cytology showed a sensitivity of 89.2% [95% confidence interval (CI); 80.7-94.2] and a specificity of 44.2% (95% CI; 40.2-48.2) to detect HGAIN. Oncogenic HPV testing had 90.4% sensitivity (95% CI; 82-86.8) and 24.4% specificity (95% CI; 20.8-28.3). Cotesting showed a 97.4% sensitivity (95% CI; 91-99.3) and 14% specificity (95% CI; 11.2-17.3). In patients with atypical squamous cells of uncertain significance on cytology, oncogenic HPV testing had 91.3% sensitivity and 28.3% specificity to detect HGAIN. Abnormal cytology and oncogenic HPV determination showed similar sensitivity for detecting HGAIN. The two tests used together improved the sensitivity but with lowered specificity. In our opinion, HPV testing does not improve HGAIN detection and should not replace anal cytology as a standard screening test for HIV-infected MSM.
Taylor, Sylvia; Wang, Chunhui; Wright, Thomas C; Denny, Lynette; Kuhn, Louise
2011-08-15
Screen-and-treat cervical cancer prevention programs based on high-risk human papillomavirus (HPV) testing and cryotherapy have been shown to be effective in resource-limited settings. However, because cryotherapy is not 100% effective, follow-up is needed after treatment to detect post-treatment failures. We compared the test performances of high-risk HPV testing (Hybrid Capture 2) using self-collected and clinician-collected samples as well as cervical cytology for identifying cervical intraepithelial neoplasia grades 2 or 3 or invasive cervical cancer (CIN2+) among women who did (n=812) and did not (n=1858) undergo cryotherapy in a South African screen-and-treat trial. At 6 months after enrolment (and after cryotherapy, if performed), women were tested using all three screening methods and then underwent colposcopy/biopsy. A predefined subset of women (n=1,455) had extended follow-up with colposcopy/biopsy at 12 months. A total of 33 and 91 cases of CIN2+ were detected among treated and untreated women, respectively. The sensitivity of HPV testing using clinician-collected samples and cervical cytology did not differ by treatment status. HPV testing of clinician-collected samples detected the most cases of CIN2+ among both treated (85%) and untreated (91%) women (p=0.31). Cytology (at a cutoff of atypical squamous cells of undetermined significance or greater) detected 76% of cases among both treated and untreated women. However, the sensitivity of HPV testing using self-collected samples was significantly lower among treated versus untreated women (55% vs. 78%, p=0.01). HPV testing using self-collected vaginal specimens may be useful in primary screening but performs poorly for detecting post-treatment failures. Copyright © 2010 UICC.
Labani, Satyanarayana; Asthana, Smita
2016-01-01
Human papillomavirus (HPV) is recommended as a primary screening tool for cervical screening. Assessment of age-specific performance of newer HPV careHPV DNA testing is important as risk of cervical intraepithelial neoplasia (CIN) varies at different ages. We aim to evaluate careHPV in comparison to Papanicolaou (Pap) test and visual inspection of the cervix with acetic acid (VIA) cervical screening tests for the detection of high-grade CIN. The cross sectional study was conducted in a rural population of North India. Ever-married women 30-59 years of age were invited for screening by careHPV (self-collected vaginal and physician-collected cervical samples), Pap test and VIA. Associations for trend in age for detecting histological-confirmed CINII+ and CINIII+ for each screening test were evaluated. Age-specific association with each screening test was evaluated. Of a total of 7761 women invited, 5032 were screened and analysis was performed on 4658 with all screen test results. No significant (p>0.05) association of age for any screening test in the detection of CINII+ or CINIII+ was observed. For the older age group, cervical HPV (CHPV) showed high sensitivity and specificity for CINII+ detection. Specificity of CHPV or vaginal HPV (VHPV) was equal or higher than Pap in all age groups. Cervical screening options of CHPV or VHPV, or Pap, performed equally in the younger age group while CHPV might be an option for all ages in the detection of high-grade CIN. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
A harmonic pulse testing method for leakage detection in deep subsurface storage formations
NASA Astrophysics Data System (ADS)
Sun, Alexander Y.; Lu, Jiemin; Hovorka, Susan
2015-06-01
Detection of leakage in deep geologic storage formations (e.g., carbon sequestration sites) is a challenging problem. This study investigates an easy-to-implement frequency domain leakage detection technology based on harmonic pulse testing (HPT). Unlike conventional constant-rate pressure interference tests, HPT stimulates a reservoir using periodic injection rates. The fundamental principle underlying HPT-based leakage detection is that leakage modifies a storage system's frequency response function, thus providing clues of system malfunction. During operations, routine HPTs can be conducted at multiple pulsing frequencies to obtain experimental frequency response functions, using which the possible time-lapse changes are examined. In this work, a set of analytical frequency response solutions is derived for predicting system responses with and without leaks for single-phase flow systems. Sensitivity studies show that HPT can effectively reveal the presence of leaks. A search procedure is then prescribed for locating the actual leaks using amplitude and phase information obtained from HPT, and the resulting optimization problem is solved using the genetic algorithm. For multiphase flows, the applicability of HPT-based leakage detection procedure is exemplified numerically using a carbon sequestration problem. Results show that the detection procedure is applicable if the average reservoir conditions in the testing zone stay relatively constant during the tests, which is a working assumption under many other interpretation methods for pressure interference tests. HPT is a cost-effective tool that only requires periodic modification of the nominal injection rate. Thus it can be incorporated into existing monitoring plans with little additional investment.
Féraudet-Tarisse, Cécile; Mazuet, Christelle; Pauillac, Serge; Krüger, Maren; Lacroux, Caroline; Popoff, Michel R; Dorner, Brigitte G; Andréoletti, Olivier; Plaisance, Marc; Volland, Hervé; Simon, Stéphanie
2017-01-01
Epsilon toxin is one of the four major toxins of Clostridium perfringens. It is the third most potent clostridial toxin after botulinum and tetanus toxins and is thus considered as a potential biological weapon classified as category B by the Centers for Disease Control and Prevention (CDC). In the case of a bioterrorist attack, there will be a need for a rapid, sensitive and specific detection method to monitor food and water contamination by this toxin, and for a simple human diagnostic test. We have produced and characterized five monoclonal antibodies against common epitopes of epsilon toxin and prototoxin. Three of them neutralize the cytotoxic effects of epsilon toxin in vitro. With these antibodies, we have developed highly sensitive tests, overnight and 4-h sandwich enzyme immunoassays and an immunochromatographic test performed in 20 min, reaching detection limits of at least 5 pg/mL (0.15 pM), 30 pg/mL (0.9 pM) and 100 pg/mL (3.5 pM) in buffer, respectively. These tests were also evaluated for detection of epsilon toxin in different matrices: milk and tap water for biological threat detection, serum, stool and intestinal content for human or veterinary diagnostic purposes. Detection limits in these complex matrices were at least 5-fold better than those described in the literature (around 1 to 5 ng/mL), reaching 10 to 300 pg/mL using the enzyme immunoassay and 100 to 2000 pg/mL using the immunochromatographic test.
Mazuet, Christelle; Pauillac, Serge; Krüger, Maren; Lacroux, Caroline; Popoff, Michel R.; Dorner, Brigitte G.; Andréoletti, Olivier; Plaisance, Marc; Volland, Hervé; Simon, Stéphanie
2017-01-01
Epsilon toxin is one of the four major toxins of Clostridium perfringens. It is the third most potent clostridial toxin after botulinum and tetanus toxins and is thus considered as a potential biological weapon classified as category B by the Centers for Disease Control and Prevention (CDC). In the case of a bioterrorist attack, there will be a need for a rapid, sensitive and specific detection method to monitor food and water contamination by this toxin, and for a simple human diagnostic test. We have produced and characterized five monoclonal antibodies against common epitopes of epsilon toxin and prototoxin. Three of them neutralize the cytotoxic effects of epsilon toxin in vitro. With these antibodies, we have developed highly sensitive tests, overnight and 4-h sandwich enzyme immunoassays and an immunochromatographic test performed in 20 min, reaching detection limits of at least 5 pg/mL (0.15 pM), 30 pg/mL (0.9 pM) and 100 pg/mL (3.5 pM) in buffer, respectively. These tests were also evaluated for detection of epsilon toxin in different matrices: milk and tap water for biological threat detection, serum, stool and intestinal content for human or veterinary diagnostic purposes. Detection limits in these complex matrices were at least 5-fold better than those described in the literature (around 1 to 5 ng/mL), reaching 10 to 300 pg/mL using the enzyme immunoassay and 100 to 2000 pg/mL using the immunochromatographic test. PMID:28700661
Kubo, Shoji; Takemura, Shigekazu; Sakata, Chikaharu; Urata, Yorihisa; Nishioka, Takayoshi; Nozawa, Akinori; Kinoshita, Masahiko; Hamano, Genya; Nakanuma, Yasuni; Endo, Ginji
2014-01-01
A cholangiocarcinoma outbreak among workers of an offset color proof-printing department in a printing company was recently reported. It is important to understand the clinical course leading to occupational cholangiocarcinoma development for investigation of the carcinogenesis process and for surveillance and early detection. We evaluated the changes in laboratory test results and diagnostic imaging presentation before the detection of cholangiocarcinoma. We investigated the changes in laboratory test results and diagnostic imaging presentation before the detection of cholangiocarcinoma in 2 patients because the data were available. Results The clinical courses observed in the 2 participating patients showed persistent elevation of serum γ-glutamyl transpeptidase levels with or without elevated serum levels of alanine aminotransferase and/or aspartate aminotransferase before cholangiocarcinoma detection. Dilatation of the bile ducts without tumor-induced stenosis was observed several years before cholangiocarcinoma detection and progressed gradually in both patients. The serum concentration of carbohydrate 19-9 also increased prior to cholangiocarcinoma detection in both patients. Eventually, observation of stenosis of the bile duct and a space-occupying lesion strongly suggested cholangiocarcinoma. Pathological examination of the resected specimens showed chronic bile duct injury and neoplastic lesions, such as "biliary intraepithelial neoplasia" and "intraductal papillary neoplasm of the bile duct" in various sites of the bile ducts, particularly in the dilated bile ducts. The changes in laboratory test results and diagnostic imaging might be related to the development of cholangiocarcinoma. It is important to monitor diagnostic imaging presentation and laboratory test results in workers with extended exposure to organic solvents.
Enriquez, G.F.; Cardinal, M.V.; Orozco, M.M.; Schijman, A.G.; Gürtler, R.E.
2013-01-01
Domestic dogs and cats are major domestic reservoir hosts of Trypanosoma cruzi and a risk factor for parasite transmission. In this study we assessed the relative performance of a polymerase chain reaction assay targeted to minicircle DNA (kDNA-PCR) in reference to conventional serological tests, a rapid dipstick test and xenodiagnosis to detect T. cruzi infection in dogs and cats from an endemic rural area in northeastern Argentina. A total of 43 dogs and 13 cats seropositive for T. cruzi by an immunosorbent assay (ELISA) and an indirect hemagglutination assay (IHA), which had been examined by xenodiagnosis, were also tested by kDNA-PCR. kDNA-PCR was nearly as sensitive as xenodiagnosis for detecting T. cruzi- infectious dogs and cats. kDNA-PCR was slightly more sensitive than xenodiagnosis in seropositive dogs (91% versus 86%, respectively) and cats (77% against 54%, respectively), but failed to detect all of the seropositive individuals. ELISA and IHA detected all xenodiagnosis-positive dogs and both outcomes largely agreed (kappa coefficient, κ = 0.92), whereas both assays failed to detect all of the xenodiagnosis-positive cats and their agreement was moderate (κ = 0.68). In dogs, the sensitivity of the dipstick test was 95% and agreed closely with the outcome of conventional serological tests (κ = 0.82). The high sensitivity of kDNA-PCR to detect T. cruzi infections in naturally-infected dogs and cats supports its application as a diagnostic tool complementary to serology and may replace the use of xenodiagnosis or hemoculture. PMID:23499860
Villar-Hernández, Raquel; Latorre, Irene; Mínguez, Sonia; Díaz, Jéssica; García-García, Esther; Muriel-Moreno, Beatriz; Lacoma, Alicia; Prat, Cristina; Olivé, Alex; Ruhwald, Morten; Mateo, Lourdes; Domínguez, José
2017-10-01
Biologic agents are used against rheumatic diseases, however, they increase the risk of developing severe infections and diseases such as tuberculosis. We aimed to determine the benefits of IP-10 detection to diagnose latent tuberculosis infection (LTBI) in patients with inflammatory rheumatic diseases on different immunosuppressive drug regimens, and compare these results with IFN-γ detection. We included 64 patients with inflammatory rheumatic diseases. We used QuantiFERON Gold In-Tube (QFN-G-IT) and T-SPOT.TB to detect IFN-γ production, and an in-house ELISA for IP-10 detection from the previous QFN-G-IT stimulated samples. We assessed the combined use of IFN-γ release assays (IGRAs) and IP-10 test, and analyzed the influence of immunotherapy on the tests performance. We obtained 34.9% positive results by T-SPOT.TB, 25.0% by QFN-G-IT and 31.3% by IP-10 test. The combined use of IGRAs and IP-10 detection increased significantly the amount of positive results (p < 0.0001). Treatment intake had no significant effect on in vitro tests (p > 0.05). IP-10 and IFN-γ detection is comparable and their combined use could increase the number of positive results in the diagnosis of LTBI in rheumatic patients. The tested assays were not influenced by rheumatoid immunosuppressive therapy. Thus, IP-10 could be of use in the development of new and improved LTBI diagnostic tools. Copyright © 2017 The British Infection Association. Published by Elsevier Ltd. All rights reserved.
Investigating the detection of multi-homed devices independent of operating systems
2017-09-01
timestamp data was used to estimate clock skews using linear regression and linear optimization methods. Analysis revealed that detection depends on...the consistency of the estimated clock skew. Through vertical testing, it was also shown that clock skew consistency depends on the installed...optimization methods. Analysis revealed that detection depends on the consistency of the estimated clock skew. Through vertical testing, it was also
USDA-ARS?s Scientific Manuscript database
Multiplex real-time PCR detection of Escherichia coli O157:H7 is an efficient molecular tool with high sensitivity and specificity for meat safety and quality assurance in the beef industry. The Biocontrol GDS and the DuPont Qualicon BAX®-RT rapid detection systems are two commercial tests based on...
Using intraindividual variability to detect malingering in cognitive performance.
Strauss, E; Hultsch, D F; Hunter, M; Slick, D J; Patry, B; Levy-Bencheton, J
1999-11-01
The utility of measures for detecting malingering was evaluated using a simulation design in which half the participants were encouraged to do their best and half were asked to feign head injury. Particular attention was focused on the utility of repeated assessment (intraindividual variability) in discriminating the groups. Participants were tested on three occasions on measures commonly used to detect malingering including a specific symptom validity test (SVT). The results indicated that multiple measures of malingering obtained in single assessment (occasion one) discriminated the groups effectively. In addition, however, intraindividual variability in performance, particularly of indicators from the SVT, provided unique information beyond level of performance. The results suggest that response inconsistency across testing sessions may be a clinically useful measure for the detection of malingering.
The Influence of Assay Design, Blinding, and Gymnema sylvestre on Sucrose Detection by Humans.
Aleman, Max G; Marconi, Lauren J; Nguyen, Nam H; Park, Jae M; Patino, Maria M; Wang, Yuchi; Watkins, Celeste S; Shelley, Chris
2016-01-01
The detection and grading of tastes corresponding to different taste modalities can be tested in engaging laboratory sessions using students themselves as test subjects. This article describes a series of experiments in which data pertaining to the detection of salty and sweet tastes are obtained, and the ability of the herb Gymnema sylvestre to disrupt the detection of sucrose is quantified. The effects of blinding and different assay designs on EC50 estimation are also investigated. The data obtained allow for substantial data analysis, including non-linear regression using fixed and free parameters to quantify dose-response relationships, and the use of often under-utilized permutation tests to determine significant differences when the underlying data display heteroscedasticity.
The Influence of Assay Design, Blinding, and Gymnema sylvestre on Sucrose Detection by Humans
Aleman, Max G.; Marconi, Lauren J.; Nguyen, Nam H.; Park, Jae M.; Patino, Maria M.; Wang, Yuchi; Watkins, Celeste S.; Shelley, Chris
2016-01-01
The detection and grading of tastes corresponding to different taste modalities can be tested in engaging laboratory sessions using students themselves as test subjects. This article describes a series of experiments in which data pertaining to the detection of salty and sweet tastes are obtained, and the ability of the herb Gymnema sylvestre to disrupt the detection of sucrose is quantified. The effects of blinding and different assay designs on EC50 estimation are also investigated. The data obtained allow for substantial data analysis, including non-linear regression using fixed and free parameters to quantify dose-response relationships, and the use of often under-utilized permutation tests to determine significant differences when the underlying data display heteroscedasticity. PMID:27980466
Sotnikov, Dmitriy V; Byzova, Nadezhda A; Zherdev, Anatoly V; Eskendirova, Saule Z; Baltin, Kairat K; Mukanov, Kasim K; Ramankulov, Erlan M; Sadykhov, Elchin G; Dzantiev, Boris B
2015-01-01
An immunochromatographic test system was developed for rapid detection of the levels of specific IgG antibodies to Brucella abortus lipopolysaccharide, as a tool for diagnosis of brucellosis in cattle. The pilot test strips were examined using blood sera from sick (78 samples) and healthy (35 samples) cows. The results obtained by immunochromatographic assay, using a portable optical densitometer for digital video detection, correlate well with the results obtained by immunoenzyme assay and are in agreement with the results of the disease diagnosis. The new test system allows detection of antibodies within 10 min and can be proposed as an alternative to the methods available for serodiagnosis of brucellosis.
Microencapsulation of Corrosion Indicators for Smart Coatings
NASA Technical Reports Server (NTRS)
Li, Wenyan; Buhrow, Jerry W.; Jolley, Scott T.; Calle, Luz M.; Hanna,Joshua S.; Rawlins, James W.
2011-01-01
A multifunctional smart coating for the autonomous detection, indication, and control of corrosion is been developed based on microencapsulation technology. This paper summarizes the development, optimization, and testing of microcapsules specifically designed for early detection and indication of corrosion when incorporated into a smart coating. Results from experiments designed to test the ability of the microcapsules to detect and indicate corrosion, when blended into several paint systems, show that these experimental coatings generate a color change, indicative of spot specific corrosion events, that can be observed with the naked eye within hours rather than the hundreds of hours or months typical of the standard accelerated corrosion test protocols.. Key words: smart coating, corrosion detection, microencapsulation, microcapsule, pH-sensitive microcapsule, corrosion indicator, corrosion sensing paint
NASA Astrophysics Data System (ADS)
Fisher, Mark; Sikes, John; Prather, Mark
2004-09-01
The dog's nose is an effective, highly-mobile sampling system, while the canine olfactory organs are an extremely sensitive detector. Having been trained to detect a wide variety of substances with exceptional results, canines are widely regarded as the 'gold standard' in chemical vapor detection. Historically, attempts to mimic the ability of dogs to detect vapors of explosives using electronic 'dogs noses' has proven difficult. However, recent advances in technology have resulted in development of detection (i.e., sampling and sensor) systems with performance that is rapidly approaching that of trained canines. The Nomadics Fido was the first sensor to demonstrate under field conditions the detection of landmines with performance approaching that of canines. More recently, comparative testing of Fido against canines has revealed that electronic vapor detection, when coupled with effective sampling methods, can produce results comparable to that of highly-trained canines. The results of these comparative tests will be presented, as will recent test results in which explosives hidden in cargo were detected using Fido with a high-volume sampling technique. Finally, the use of canines along with electronic sensors will be discussed as a means of improving the performance and expanding the capabilities of both methods.
Vollenhofer-Schrumpf, Sabine; Buresch, Ronald; Schinkinger, Manfred
2007-03-01
We have developed a new method for the detection of nucleic acid hybridization, based on a simple latex agglutination test that can be evaluated by the unaided eye. Nucleic acid, e.g., a polymerase chain reaction (PCR) product, is denatured and incubated with polystyrene beads carrying covalently bound complementary oligonucleotide sequences. Hybridization of the nucleic acids leads to aggregation of the latex particles, thereby verifying the presence of target sequence. The test is performed at room temperature, and results are available within 10 min. As a proof of principle, the hybridization/latex agglutination assay was applied to the detection of purified PCR fragments either specific for Salmonella spp. or a synthetic sequence, and to the detection of Salmonella enterica in artificially contaminated chicken samples. A few nanograms of purified PCR fragments were detectable. In artificially contaminated chicken samples, 3 colony-forming units (cfu)/25 g were detected in one of three replicates, and 30 cfu/25 g were detected in both of two replicates when samples for PCR were taken directly from primary enrichment, demonstrating the practical applicability of this test system. Even multiplex detection might be achievable. This novel kind of assay could be useful for a range of applications where hybridization of nucleic acids, e.g., PCR fragments, is to be detected.
Detecting gear tooth fracture in a high contact ratio face gear mesh
NASA Technical Reports Server (NTRS)
Zakrajsek, James J.; Handschuh, Robert F.; Lewicki, David G.; Decker, Harry J.
1995-01-01
This paper summarized the results of a study in which three different vibration diagnostic methods were used to detect gear tooth fracture in a high contact ratio face gear mesh. The NASA spiral bevel gear fatigue test rig was used to produce unseeded fault, natural failures of four face gear specimens. During the fatigue tests, which were run to determine load capacity and primary failure mechanisms for face gears, vibration signals were monitored and recorded for gear diagnostic purposes. Gear tooth bending fatigue and surface pitting were the primary failure modes found in the tests. The damage ranged from partial tooth fracture on a single tooth in one test to heavy wear, severe pitting, and complete tooth fracture of several teeth on another test. Three gear fault detection techniques, FM4, NA4*, and NB4, were applied to the experimental data. These methods use the signal average in both the time and frequency domain. Method NA4* was able to conclusively detect the gear tooth fractures in three out of the four fatigue tests, along with gear tooth surface pitting and heavy wear. For multiple tooth fractures, all of the methods gave a clear indication of the damage. It was also found that due to the high contact ratio of the face gear mesh, single tooth fractures did not significantly affect the vibration signal, making this type of failure difficult to detect.
A Novel Molecular Test to Diagnose Canine Visceral Leishmaniasis at the Point of Care
Castellanos-Gonzalez, Alejandro; Saldarriaga, Omar A.; Tartaglino, Lilian; Gacek, Rosana; Temple, Elissa; Sparks, Hayley; Melby, Peter C.; Travi, Bruno L.
2015-01-01
Dogs are the principal reservoir hosts of zoonotic visceral leishmaniasis (VL) but current serological methods are not sensitive enough to detect all subclinically infected animals, which is crucial to VL control programs. Polymerase chain reaction (PCR) methods have greater sensitivity but require expensive equipment and trained personnel, impairing its implementation in endemic areas. We developed a diagnostic test that uses isothermal recombinase polymerase amplification (RPA) to detect Leishmania infantum. This method was coupled with lateral flow (LF) reading with the naked eye to be adapted as a point-of-care test. The L. infantum RPA-LF had an analytical sensitivity similar to real time-PCR, detecting DNA of 0.1 parasites spiked in dog blood, which was equivalent to 40 parasites/mL. There was no cross amplification with dog or human DNA or with Leishmania braziliensis, Leishmania amazonensis, or Trypanosoma cruzi. The test also amplified Leishmania donovani strains (N = 7). In a group of clinically normal dogs (N = 30), RPA-LF detected more subclinical infections than rK39 strip test, a standard serological method (50% versus 13.3% positivity, respectively; P = 0.005). Also, RPA-LF detected L. infantum in noninvasive mucosal samples of dogs with a sensitivity comparable to blood samples. This novel molecular test may have a positive impact in leishmaniasis control programs. PMID:26240156
The presence-absence coliform test for monitoring drinking water quality.
Rice, E W; Geldreich, E E; Read, E J
1989-01-01
The concern for improved monitoring of the sanitary quality of drinking water has prompted interest in alternative methods for the detection of total coliform bacteria. A simplified qualitative presence-absence test has been proposed as an alternate procedure for detecting coliform bacteria in potable water. In this paper data from four comparative studies were analyzed to compare the recovery of total coliform bacteria from drinking water using the presence-absence test, the multiple fermentation tube procedure, and the membrane filter technique. The four studies were of water samples taken from four different geographic areas of the United States: Hawaii, New England (Vermont and New Hampshire), Oregon, and Pennsylvania. Analysis of the results of these studies were compared, based upon the number of positive samples detected by each method. Combined recoveries showed the presence-absence test detected significantly higher numbers of samples with coliforms than either the fermentation tube or membrane filter methods, P less than 0.01. The fermentation tube procedure detected significantly more positive samples than the membrane filter technique, P less than 0.01. Based upon the analysis of the combined data base, it is clear that the presence-absence test is as sensitive as the current coliform methods for the examination of potable water. The presence-absence test offers a viable alternative to water utility companies that elect to use the frequency-of-occurrence approach for compliance monitoring. PMID:2493663
Investigating prior probabilities in a multiple hypothesis test for use in space domain awareness
NASA Astrophysics Data System (ADS)
Hardy, Tyler J.; Cain, Stephen C.
2016-05-01
The goal of this research effort is to improve Space Domain Awareness (SDA) capabilities of current telescope systems through improved detection algorithms. Ground-based optical SDA telescopes are often spatially under-sampled, or aliased. This fact negatively impacts the detection performance of traditionally proposed binary and correlation-based detection algorithms. A Multiple Hypothesis Test (MHT) algorithm has been previously developed to mitigate the effects of spatial aliasing. This is done by testing potential Resident Space Objects (RSOs) against several sub-pixel shifted Point Spread Functions (PSFs). A MHT has been shown to increase detection performance for the same false alarm rate. In this paper, the assumption of a priori probability used in a MHT algorithm is investigated. First, an analysis of the pixel decision space is completed to determine alternate hypothesis prior probabilities. These probabilities are then implemented into a MHT algorithm, and the algorithm is then tested against previous MHT algorithms using simulated RSO data. Results are reported with Receiver Operating Characteristic (ROC) curves and probability of detection, Pd, analysis.
Health responsibility and workplace health promotion among women: early detection of cancer.
Kushnir, T; Rabinowitz, S; Melamed, S; Weisberg, E; Ribak, J
1995-01-01
The importance of health responsibility as one aspect of a health-promoting lifestyle has been emphasized repeatedly. Yet there are only a few empirical studies of its role in preventive behavior. We examined the relationship between health responsibility and early-detection practices for breast and cervical cancer. A group of 253 women employees of a large industrial company participated in a cancer screening program subsidized by the employer. They completed questionnaires assessing health responsibility and reported early-detection practices: frequency of breast self-examination and physician breast examinations, frequency of Pap tests, and time lapsed since last Pap test and breast examinations. Health responsibility was a significant independent predictor of breast examination indicators but not of Pap tests. Education level was an important predictor for Pap tests, and age predicted most early-detection practices. The findings lend some support to the role of health responsibility in initiating breast examinations. Better prediction of early-detection practices could be achieved by adding cognitive and emotional components to the existing responsibility scale and by distinguishing between retrospective and prospective responsibility.
The detection limits of antimicrobial agents in cow's milk by a simple Yoghurt Culture Test.
Mohsenzadeh, M; Bahrainipour, A
2008-09-15
The aim of this study was to study performance of Yoghurt Culture Test (YCT) in the detection of antimicrobial residues in milk. For this purpose, the sensitivity of YCT for 15 antibiotics were determined. For each drug, 8 concentrations were tested. The detection limits of YCT at 2.5 h and 4 h incubation were determined (microg kg(-1)): 15 and 37.5, penicillin G; 4 and 5, ampicillin; 5 and 7.5, amoxycillin; 100 and 200, cephalexin; 80 and 100, cefazoline; 100 and 200, oxytetracycline; 500 and 100, chlortetracycline; 100 and 200, tetracycline; 150 and 200, doxycycline; 200 and 400, sulphadimidine; 500 and 1000, gentamycin; 1000 and 1500, spectinomycin; 400 and 500, erythromycin; 50 and 100, tylosin; 5000 and 10000, chloramphenicol. The YCT detection limits at 2.5 h incubation for ampicillin, cephalexin, tetracycline, oxytetracycline and tylosin are similar to those obtained as Maximum Residue Limit (MRL) according to Regulation 2377/90 EEC as set out by the European Union. In addition the detection limits of YCT for some antibiotics were lower than some of microbial inhibitor test.
49 CFR 234.227 - Train detection apparatus.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 4 2010-10-01 2010-10-01 false Train detection apparatus. 234.227 Section 234.227..., Inspection, and Testing Maintenance Standards § 234.227 Train detection apparatus. (a) Train detection apparatus shall be maintained to detect a train or railcar in any part of a train detection circuit, in...
49 CFR 234.227 - Train detection apparatus.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 4 2011-10-01 2011-10-01 false Train detection apparatus. 234.227 Section 234.227..., Inspection, and Testing Maintenance Standards § 234.227 Train detection apparatus. (a) Train detection apparatus shall be maintained to detect a train or railcar in any part of a train detection circuit, in...
Papeš, Dino; Pasini, Miram; Jerončić, Ana; Vargović, Martina; Kotarski, Viktor; Markotić, Alemka; Škerk, Višnja
2017-05-01
In <10% of patients with prostatitis syndrome, a causative uropathogenic organism can be detected. It has been shown that certain organisms that cause sexually transmitted infections can also cause chronic bacterial prostatitis, which can be hard to diagnose and treat appropriately because prostatic samples obtained by prostatic massage are not routinely tested to detect them. We conducted a clinical study to determine the prevalence of Chlamydia, mycoplasma, and trichomonas infection in 254 patients that were previously diagnosed and treated for chronic prostatitis/chronic pelvic pain syndrome due to negative urethral swab, urine, and prostate samples. Urethral swabs and standard Meares-Stamey four-glass tests were done. Detailed microbiological analysis was conducted to detect the above organisms. Thirty-five (13.8%) patients had positive expressed prostatic secretions/VB3 samples, of which 22 (10.1%) were sexually transmitted organisms that were not detected on previous tests.
Performance of RASS vortex detection/measurement system
DOT National Transportation Integrated Search
1999-06-01
Preliminary tests conducted by WLR Research in the Fall of 1993 showed considerable promise that a Radio Acoustic Sounding System (RASS) was capable of detecting and tracking wake vortices located in the approach glide slope. Initial testing of the R...
Testing & Evaluation of Close-Range SAR for Monitoring & Automatically Detecting Pavement Conditions
DOT National Transportation Integrated Search
2012-01-01
This report summarizes activities in support of the DOT contract on Testing & Evaluating Close-Range SAR for Monitoring & Automatically Detecting Pavement Conditions & Improve Visual Inspection Procedures. The work of this project was performed by Dr...
Singh, Manju; Singh, Shoor Vir; Gupta, Saurabh; Chaubey, Kundan Kumar; Stephan, Bjorn John; Sohal, Jagdip Singh; Dutta, Manali
2018-04-26
Early rapid detection of Mycobacterium avium subspecies paratuberculosis (MAP) bacilli in milk samples is the major challenge since traditional culture method is time consuming and laboratory dependent. We report a simple, sensitive and specific nano-technology based 'Nano-immuno test' capable of detecting viable MAP bacilli in the milk samples within 10 h. Viable MAP bacilli were captured by MAP specific antibody-conjugated magnetic nano-particles using resazurin dye as chromogen. Test was optimized using true culture positive (10-bovine and 12-goats) and true culture negative (16-bovine and 25-goats) raw milk samples. Domestic livestock species in India are endemically infected with MAP. After successful optimization, sensitivity and specificity of the 'nano-immuno test' in goats with respect to milk culture was 91.7% and 96.0%, respectively. Whereas, it was 90.0% (sensitivity) and 92.6% (specificity) with respect to IS900 PCR. In bovine milk samples, sensitivity and specificity of 'nano-immuno test' with respect to milk culture was 90.0% and 93.7%, respectively. However, with respect to IS900 PCR, the sensitivity and specificity was 88.9% and 94.1%, respectively. Test was validated with field raw milk samples (goats-258 and bovine-138) collected from domestic livestock species to detect live/viable MAP bacilli. Of 138 bovine raw milk samples screened by six diagnostic tests, 81 (58.7%) milk samples were positive for MAP infection in one or more than one diagnostic tests. Of 81 (58.7%) positive bovine raw milk samples, only 24 (17.4%) samples were detected positive for the presence of viable MAP bacilli. Of 258 goats raw milk samples screened by six diagnostic tests, 141 (54.6%) were positive for MAP infection in one or more than one test. Of 141 (54.6%) positive raw milk samples from goats, only 48 (34.0%) were detected positive for live MAP bacilli. Simplicity and efficiency of this novel 'nano-immuno test' makes it suitable for wide-scale screening of milk samples in the field. Standardization, validation and re-usability of functionalized nano-particles and the test was successfully achieved in field samples. Test was highly specific, simple to perform and easy to read by naked eyes and does not require laboratory support in the performance of test. Test has potential to be used as screening test to estimate bio-load of MAP in milk samples at National level.
Using permutations to detect dependence between time series
NASA Astrophysics Data System (ADS)
Cánovas, Jose S.; Guillamón, Antonio; Ruíz, María del Carmen
2011-07-01
In this paper, we propose an independence test between two time series which is based on permutations. The proposed test can be carried out by means of different common statistics such as Pearson’s chi-square or the likelihood ratio. We also point out why an exact test is necessary. Simulated and real data (return exchange rates between several currencies) reveal the capacity of this test to detect linear and nonlinear dependences.
PSK Shift Timing Information Detection Using Image Processing and a Matched Filter
2009-09-01
phase shifts are enhanced. Develop, design, and test the resulting phase shift identification scheme. xx Develop, design, and test an optional...and the resulting phase shift identification algorithm is investigated for SNR levels in the range -2dB to 12 dB. Detection performances are derived...test the resulting phase shift identification scheme. Develop, design, and test an optional analysis window overlapping technique to improve phase
Nano-LISA for in vitro diagnostic applications
NASA Astrophysics Data System (ADS)
Maswadi, Saher; Glickman, Randolph D.; Elliott, Rowe; Barsalou, Norman
2011-03-01
We previously reported the detection of bacterial antigen with immunoaffinity reactions using laser optoacoustic spectroscopy and antibody-coupled gold nanorods (Ab-NR) as a contrast agent specifically targeted to the antigen of interest. The Nano-LISA (Nanoparticle Linked Immunosorbent Assay) method has been adapted to detect three very common blood-borne viral infectious agents, i.e. human T-lymphotropic virus (HTLV), human immunodeficiency virus (HIV) and hepatitis-B (Hep-B). These agents were used in a model test panel to illustrate the performance of the Nano-LISA technique. A working laboratory prototype of a Nano-LISA microplate reader-sensor was assembled and tested against the panel containing specific antigens of each of the infectious viral agents. Optoacoustic (OA) responses generated by the samples were detected using the probe beam deflection technique, an all-optical, non-contact technique. A LabView graphical user interface was developed for control of the instrument and real-time display of the test results. The detection limit of Nano-LISA is at least 1 ng/ml of viral antigen, and can reach 10 pg/ml, depending on the binding affinity of the specific detection antibody used to synthesize the Ab-NR. The method has sufficient specificity, i.e. the detection reagents do not cross-react with noncomplementary antigens. Thus, the OA microplate reader, incorporating NanoLISA, has adequate detection sensitivity and specificity for use in clinical in vitro diagnostic testing.
Niedermaier, Tobias; Weigl, Korbinian; Hoffmeister, Michael; Brenner, Hermann
2017-01-01
Background Colorectal cancer (CRC) is a common but largely preventable cancer. Although fecal immunochemical tests (FITs) detect the majority of CRCs, they miss some of the cancers and most advanced adenomas (AAs). The potential of blood tests in complementing FITs for the detection of CRC or AA has not yet been systematically investigated. Methods We conducted a systematic review of performance of FIT combined with an additional blood test for CRC and AA detection versus FIT alone. PubMed and Web of Science were searched until June 9, 2017. Results Some markers substantially increased sensitivity for CRC when combined with FIT, albeit typically at a major loss of specificity. For AA, no relevant increase in sensitivity could be achieved. Conclusion Combining FIT and blood tests might be a promising approach to enhance sensitivity of CRC screening, but comprehensive evaluation of promising marker combinations in screening populations is needed. PMID:29435309
Sweat testing to evaluate autonomic function
Illigens, Ben M.W.; Gibbons, Christopher H.
2011-01-01
Sudomotor dysfunction is one of the earliest detectable neurophysiologic abnormalities in distal small fiber neuropathy. Traditional neurophysiologic measurements of sudomotor function include thermoregulatory sweat testing (TST), quantitative sudomotor axon reflex testing (QSART), silicone impressions, the sympathetic skin response (SSR), and the recent addition of quantitative direct and indirect axon reflex testing (QDIRT). These testing techniques, when used in combination, can detect and localized pre- and postganglionic lesions, can provide early diagnosis of sudomotor dysfunction and can monitor disease progression or disease recovery. In this article, we review the common tests available for assessment of sudomotor function, detail the testing methodology, review the limitations and provide examples of test results. PMID:18989618
Badoux, Paul; Euser, Sjoerd M; Bruin, Jacob P; Mulder, Patrick P G; Yzerman, Ed P F
2017-06-01
In this study, we compared the bioNexia test (bioMérieux, Marcy-l'Étoile, France), a new immunochromatographic assay for the detection of Legionella pneumophila serogroup 1 in urine, with the BinaxNOW urinary antigen test (Alere, Waltham, Massachusetts, USA). After 15 min of incubation (in accordance with the manufacturers' instructions), the sensitivities and specificities were, respectively, 76.5% and 97.2% for the bioNexia test and 87.1% and 100% for the BinaxNOW test. After a prolonged incubation time of 60 min, the sensitivities and specificities increased to, respectively, 89.4% and 97.2% for the bioNexia test and 91.8% and 100% for the BinaxNOW test. When the tests were read after 15 min, the concentration of discrepant urine samples increased the sensitivities to 94.1% for both tests. In conclusion, we found that although the bioNexia test showed lower sensitivity for the detection of L. pneumophila antigen in nonconcentrated urine compared to the BinaxNOW test, a prolonged incubation time as well as the use of concentrated samples showed comparable sensitivities for both tests. Copyright © 2017 American Society for Microbiology.
Multiplex PCR Tests for Detection of Pathogens Associated with Gastroenteritis
Zhang, Hongwei; Morrison, Scott; Tang, Yi-Wei
2016-01-01
Synopsis A wide range of enteric pathogens can cause infectious gastroenteritis. Conventional diagnostic algorithms including culture, biochemical identification, immunoassay and microscopic examination are time consuming and often lack sensitivity and specificity. Advances in molecular technology have as allowed its use as clinical diagnostic tools. Multiplex PCR based testing has made its way to gastroenterology diagnostic arena in recent years. In this article we present a review of recent laboratory developed multiplex PCR tests and current commercial multiplex gastrointestinal pathogen tests. We will focus on two FDA cleared commercial syndromic multiplex tests: Luminex xTAG GPP and Biofire FimArray GI test. These multiplex tests can detect and identify multiple enteric pathogens in one test and provide results within hours. Multiplex PCR tests have shown superior sensitivity to conventional methods for detection of most pathogens. The high negative predictive value of these multiplex tests has led to the suggestion that they be used as screening tools especially in outbreaks. Although the clinical utility and benefit of multiplex PCR test are to be further investigated, implementing these multiplex PCR tests in gastroenterology diagnostic algorithm has the potential to improve diagnosis of infectious gastroenteritis. PMID:26004652
Hermetic Seal Leak Detection Apparatus with Variable Size Test Chamber
NASA Technical Reports Server (NTRS)
Kelley, Anthony R. (Inventor)
2015-01-01
The present invention is a versatile hermetic seal leak detection apparatus for testing hermetically sealed containers and devices for leaks without the need to create a custom or specially manufactured testing chamber conforming to the dimensions of the specific object under test. The size of the testing chamber may be mechanically adjusted by the novel use of bellows to reduce and optimize the amount of gas space in a test chamber which surrounds the hermetically sealed object under test. The present invention allows the size of the test chamber to be selectively adjusted during testing to provide an optimum test chamber gas space. The present invention may be further adapted to isolate and test specific portions of the hermetically sealed object under test for leaks.
Passarge, Michelle; Fix, Michael K; Manser, Peter; Stampanoni, Marco F M; Siebers, Jeffrey V
2017-04-01
To develop a robust and efficient process that detects relevant dose errors (dose errors of ≥5%) in external beam radiation therapy and directly indicates the origin of the error. The process is illustrated in the context of electronic portal imaging device (EPID)-based angle-resolved volumetric-modulated arc therapy (VMAT) quality assurance (QA), particularly as would be implemented in a real-time monitoring program. A Swiss cheese error detection (SCED) method was created as a paradigm for a cine EPID-based during-treatment QA. For VMAT, the method compares a treatment plan-based reference set of EPID images with images acquired over each 2° gantry angle interval. The process utilizes a sequence of independent consecutively executed error detection tests: an aperture check that verifies in-field radiation delivery and ensures no out-of-field radiation; output normalization checks at two different stages; global image alignment check to examine if rotation, scaling, and translation are within tolerances; pixel intensity check containing the standard gamma evaluation (3%, 3 mm) and pixel intensity deviation checks including and excluding high dose gradient regions. Tolerances for each check were determined. To test the SCED method, 12 different types of errors were selected to modify the original plan. A series of angle-resolved predicted EPID images were artificially generated for each test case, resulting in a sequence of precalculated frames for each modified treatment plan. The SCED method was applied multiple times for each test case to assess the ability to detect introduced plan variations. To compare the performance of the SCED process with that of a standard gamma analysis, both error detection methods were applied to the generated test cases with realistic noise variations. Averaged over ten test runs, 95.1% of all plan variations that resulted in relevant patient dose errors were detected within 2° and 100% within 14° (<4% of patient dose delivery). Including cases that led to slightly modified but clinically equivalent plans, 89.1% were detected by the SCED method within 2°. Based on the type of check that detected the error, determination of error sources was achieved. With noise ranging from no random noise to four times the established noise value, the averaged relevant dose error detection rate of the SCED method was between 94.0% and 95.8% and that of gamma between 82.8% and 89.8%. An EPID-frame-based error detection process for VMAT deliveries was successfully designed and tested via simulations. The SCED method was inspected for robustness with realistic noise variations, demonstrating that it has the potential to detect a large majority of relevant dose errors. Compared to a typical (3%, 3 mm) gamma analysis, the SCED method produced a higher detection rate for all introduced dose errors, identified errors in an earlier stage, displayed a higher robustness to noise variations, and indicated the error source. © 2017 American Association of Physicists in Medicine.
Development of adapted GMR-probes for automated detection of hidden defects in thin steel sheets
NASA Astrophysics Data System (ADS)
Pelkner, Matthias; Pohl, Rainer; Kreutzbruck, Marc; Commandeur, Colin
2016-02-01
Thin steel sheets with a thickness of 0.3 mm and less are the base materials of many everyday life products (cans, batteries, etc.). Potential inhomogeneities such as non-metallic inclusions inside the steel can lead to a rupture of the sheets when it is formed into a product such as a beverage can. Therefore, there is a need to develop automated NDT techniques to detect hidden defects and inclusions in thin sheets during production. For this purpose Tata Steel Europe and BAM, the Federal Institute for Materials Research and Testing (Germany), collaborate in order to develop an automated NDT-system. Defect detection systems have to be robust against external influences, especially when used in an industrial environment. In addition, such a facility has to achieve a high sensitivity and a high spatial resolution in terms of detecting small inclusions in the μm-regime. In a first step, we carried out a feasibility study to determine which testing method is promising for detecting hidden defects and inclusions inside ferrous thin steel sheets. Therefore, two methods were investigated in more detail - magnetic flux leakage testing (MFL) using giant magneto resistance sensor arrays (GMR) as receivers [1,2] and eddy current testing (ET). The capabilities of both methods were tested with 0.2 mm-thick steel samples containing small defects with depths ranging from 5 µm up to 60 µm. Only in case of GMR-MFL-testing, we were able to detect parts of the hidden defects with a depth of 10 µm trustworthily with a SNR better than 10 dB. Here, the lift off between sensor and surface was 250 µm. On this basis, we investigated different testing scenarios including velocity tests and different lift offs. In this contribution we present the results of the feasibility study leading to first prototypes of GMR-probes which are now installed as part of a demonstrator inside a production line.
Simmons, Ann Marie; Rowneki, Mazhgan; Parmar, Heta; Cao, Yuan; Ryan, Jamie; Banada, Padmapriya P.; Deshpande, Srinidhi; Shenai, Shubhada; Gall, Alexander; Glass, Jennifer; Krieswirth, Barry; Schumacher, Samuel G.; Nabeta, Pamela; Tukvadze, Nestani; Rodrigues, Camilla; Skrahina, Alena; Tagliani, Elisa; Cirillo, Daniela M.; Davidow, Amy; Denkinger, Claudia M.; Persing, David; Kwiatkowski, Robert; Jones, Martin
2017-01-01
ABSTRACT The Xpert MTB/RIF assay (Xpert) is a rapid test for tuberculosis (TB) and rifampin resistance (RIF-R) suitable for point-of-care testing. However, it has decreased sensitivity in smear-negative sputum, and false identification of RIF-R occasionally occurs. We developed the Xpert MTB/RIF Ultra assay (Ultra) to improve performance. Ultra and Xpert limits of detection (LOD), dynamic ranges, and RIF-R rpoB mutation detection were tested on Mycobacterium tuberculosis DNA or sputum samples spiked with known numbers of M. tuberculosis H37Rv or Mycobacterium bovis BCG CFU. Frozen and prospectively collected clinical samples from patients suspected of having TB, with and without culture-confirmed TB, were also tested. For M. tuberculosis H37Rv, the LOD was 15.6 CFU/ml of sputum for Ultra versus 112.6 CFU/ml of sputum for Xpert, and for M. bovis BCG, it was 143.4 CFU/ml of sputum for Ultra versus 344 CFU/ml of sputum for Xpert. Ultra resulted in no false-positive RIF-R specimens, while Xpert resulted in two false-positive RIF-R specimens. All RIF-R-associated M. tuberculosis rpoB mutations tested were identified by Ultra. Testing on clinical sputum samples, Ultra versus Xpert, resulted in an overall sensitivity of 87.5% (95% confidence interval [CI], 82.1, 91.7) versus 81.0% (95% CI, 74.9, 86.2) and a sensitivity on sputum smear-negative samples of 78.9% (95% CI, 70.0, 86.1) versus 66.1% (95% CI, 56.4, 74.9). Both tests had a specificity of 98.7% (95% CI, 93.0, 100), and both had comparable accuracies for detection of RIF-R in these samples. Ultra should significantly improve TB detection, especially in patients with paucibacillary disease, and may provide more-reliable RIF-R detection. PMID:28851844
Anderson, Steven; Bloom, Kenneth J; Vallera, Dino U; Rueschoff, Josef; Meldrum, Cliff; Schilling, Robert; Kovach, Barbara; Lee, Ju Ruey-Jiuan; Ochoa, Pam; Langland, Rachel; Halait, Harkanwal; Lawrence, H Jeffrey; Dugan, Michael C
2012-11-01
A polymerase chain reaction-based companion diagnostic (cobas 4800 BRAF V600 Mutation Test) was recently approved by the US Food and Drug Administration to select patients with BRAF-mutant metastatic melanoma for treatment with the BRAF inhibitor vemurafenib. (1) To compare the analytic performance of the cobas test to Sanger sequencing by using screening specimens from phase II and phase III trials of vemurafenib, and (2) to assess the reproducibility of the cobas test at different testing sites. Specimens from 477 patients were used to determine positive and negative percent agreements between the cobas test and Sanger sequencing for detecting V600E (1799T>A) mutations. Specimens were evaluated with a massively parallel pyrosequencing method (454) to resolve discordances between polymerase chain reaction and Sanger results. Reproducibility of the cobas test was assessed at 3 sites by using 3 reagent lots and an 8-member panel of melanoma samples. A valid cobas result was obtained for all eligible patients. Sanger sequencing had a failure rate of 9.2% (44 of 477). For the remaining 433 specimens, positive percent agreement was 96.4% (215 of 223) and negative percent agreement, 80% (168 of 210). Among 42 cobas mutation-positive/Sanger V600E-negative specimens, 17 were V600E positive and 24 were V600K positive by 454. The cobas test detected 70% of V600K mutations. In the reproducibility study, a correct interpretation was made for 100% of wild-type specimens and specimens with greater than 5% mutant alleles; V600E mutations were detected in 90% of specimens with less than 5% mutant alleles. The cobas test (1) had a lower assay failure rate than that of Sanger, (2) was more sensitive in detecting V600E mutations, (3) detected most V600K mutations, and (4) was highly reproducible.
Burgess, B A; Noyes, N R; Bolte, D S; Hyatt, D R; van Metre, D C; Morley, P S
2015-01-01
Salmonella enterica is the most commonly reported cause of outbreaks of nosocomial infections in large animal veterinary teaching hospitals and the closure of equine hospitals. Rapid detection may facilitate effective control practices in equine populations. Shipping and laboratory testing typically require ≥48 h to obtain results. Lateral flow immunoassays developed for use in food-safety microbiology provide an alternative that has not been evaluated for use with faeces or environmental samples. We aimed to identify enrichment methods that would allow commercially available rapid Salmonella detection systems (lateral flow immunoassays) to be used in clinical practice with equine faecal and environmental samples, providing test results in 18-24 h. In vitro experiment. Equine faecal and environmental samples were inoculated with known quantities of S. enterica serotype Typhimurium and cultured using 2 different enrichment techniques for faeces and 4 enrichment techniques for environmental samples. Samples were tested blindly using 2 different lateral flow immunoassays and plated on agar media for confirmatory testing. In general, commercial lateral flow immunoassays resulted in fewer false-negative test results with enrichment of 1 g faecal samples in tetrathionate for 18 h, while all environmental sample enrichment techniques resulted in similar detection rates. The limit of detection from spiked samples, ∼4 colony-forming units/g, was similar for all methods evaluated. The lateral flow immunoassays evaluated could reliably detect S. enterica within 18 h, indicating that they may be useful for rapid point-of-care testing in equine practice applications. Additional evaluation is needed using samples from naturally infected cases and the environment to gain an accurate estimate of test sensitivity and specificity and to substantiate further the true value of these tests in clinical practice. © 2014 EVJ Ltd.
Kuzmenko, E T; Labigina, A V; Leshenko, O Ya; Rusanov, D N; Kuzmenko, V V; Fedko, L P; Pak, I P
2015-05-01
The analysis of results of screening (n = 3208; sexually active citizen aged from 18 to 59 years) was carried out to detect oncogene types of human papilloma virus in using qualitative (1150 females and 720 males) and quantitative (polymerase chain reaction in real-time (843 females and 115 males) techniques. The human papilloma virus of high oncogene type was detected in 65% and 68.4% of females and in 48.6% and 53% of males correspondingly. Among 12 types of human papilloma virus the most frequently diagnosed was human papilloma virus 16 independently of gender of examined and technique of analysis. In females, under application of qualitative tests rate of human papilloma virus 16 made up to 18.3% (n = 280) and under application of quantitative tests Rte of human papilloma virus made up to 14.9% (n = 126; p ≤ 0.05). Under examination of males using qualitative tests rate of human papilloma virus 16 made up to 8.3% (n = 60) and under application of qualitative tests made up to 12.2% (n = 14; p ≥ 0.05). Under application of qualitative tests rate of detection on the rest ofoncogene types of human papilloma virus varied in females from 3.4% to 8.4% and in males from 1.8% to 5.9%. Under application of qualitative tests to females rate of human papilloma virus with high viral load made up to 68.4%, with medium viral load - 2.85% (n = 24) and with low viral load -0.24% (n = 2). Under application of quantitative tests in males rate of detection of types of human papilloma virus made up to 53% and at that in all high viral load was established. In females, the most of oncogene types of human papilloma virus (except for 31, 39, 59) are detected significantly more often than in males.
Meylan, Pascal; Paris, Luc; Liesenfeld, Oliver
2015-01-01
Detection of IgG and IgM antibodies is commonly performed for the diagnosis of infection with Toxoplasma gondii. We determined the accuracy of the Elecsys Toxo IgG and IgM test at four European laboratories compared to local reference methods. Coefficients of variation for reproducibility ranged from 1.0 to 6.5% for IgG and from 0.8 to 3.2% for IgM. Seroconversion panels revealed high overall concordance with the reference tests. The Elecsys test detected IgG antibodies earlier than the Cobas Core IgG test in 19 of 47 panels; persisting IgM antibodies were observed in the VIDAS but not the Elecsys test in five of 47 panels. In 31.4% of latent stage sera with persistent IgM antibodies (positive LIASON IgM), the Elecsys IgM test gave negative results indicating increased “clinical” specificity. Sensitivity and specificity of the Elecsys IgG assay ranged from 99.45 to 100% and 87.50–99.80%, respectively, and 91.11–95.74 and 98.45–99.79% for the Elecsys IgM assay, respectively. In conclusion, excellent reproducibility and accuracy make the Elecsys Toxo G and M tests highly suitable for the detection of anti-T. gondii IgG and IgM antibodies. The lower detection rates for persistent IgM in the Elecsys IgM test increase “clinical” specificity and decrease the need for follow-up testing. PMID:26185683
Schvartz, Gili; Epp, Tasha; Burgess, Hilary J; Chilton, Neil B; Lohmann, Katharina L
2015-07-01
To investigate the agreement between available serologic tests for the detection of antibodies against Anaplasma phagocytophilum and Borrelia burgdorferi, 50 serum samples from horses of unknown clinical status and at low risk for infection were tested. In addition to a point-of-care enzyme-linked immunosorbent assay (pocELISA), the evaluated tests included 2 indirect fluorescent antibody tests (IFATs) for antibodies against A. phagocytophilum and an IFAT, an ELISA confirmed with Western blot, and the Lyme multiplex assay for antibodies against B. burgdorferi. For each pair-wise comparison between serologic tests, the difference in the proportion of seropositive results as well as kappa and the prevalence-adjusted, bias-adjusted kappa were calculated. The proportion of seropositive results differed significantly in each pairwise comparison of tests for detection of antibodies against A. phagocytophilum, and between the pocELISA and IFAT as well as between the pocELISA and Lyme multiplex assay for detection of antibodies against B. burgdorferi. Agreement based on kappa varied from poor to fair while agreement was improved when evaluating prevalence-adjusted, bias-adjusted kappa. Lack of agreement may be explained by differences in methodology between the evaluated tests, cross-reactivity or false-positive and false-negative tests. In addition to the limitations of serologic test interpretation in the absence of clinical disease, this data suggest that screening of horses for exposure to tick-borne diseases in nonendemic areas may not be warranted. © 2015 The Author(s).
Detection of Cytomegalovirus (CMV) Infection in Wheezing Infants by Urine DNA and Serum IgG Testing.
Zeng, Zhao-Cheng; Chang, Qing; Sun, Zhi-Wei; Song, Ming-Mei; Jin, Xin-Ling; Jiang, Shu-Ya; Yang, Xia
2017-03-11
BACKGROUND The aim of this study was to investigate the involvement of CMV infection in wheezing infants and the association between CMV-DNA and immunoglobulins (Igs). MATERIAL AND METHODS A total of 243 wheezing infants and 3,000 parturients were enrolled in this study. The infants were randomly grouped to receive blood HCMV-DNA tests (n=46) or urine HCMV-DNA tests (n=197). Furthermore, all participants had serum CMV-specific IgM and IgG testing. Afterwards, 10 HCMV-IgG positive infants were randomly selected for simultaneous blood and urine HCMV-DNA tests, and 25 HCMV-IgG positive puerperants were randomly selected for urine HCMV-DNA tests. RESULTS The detection rate of urine HCMV-DNA was significantly higher than that of blood HCMV-DNA (67.5% vs. 13.0%, p<0.001). Fifteen (6.2%) and 190 (80.0%) infants showed positive CMV-specific IgM and IgG results (p<0.001), respectively. Among the 10 HCMV-IgG positive infants tested further, only two infants had positive HCMV-DNA blood tests, while all of the 10 infants had positive HCMV-DNA urine tests. However, HCMV-DNA was not detected in the urine of the 25 randomly selected parturients positive for HCMV-IgG. CONCLUSIONS CMV infection may be one of the causes of wheezing in infants; CMV infection can be detected by urine-HCMV-DNA and serum HCMV-IgG testing. Infants were more susceptible to CMV infection than parturients.
Detection of swine-origin influenza A (H1N1) viruses using a paired surface plasma waves biosensor
NASA Astrophysics Data System (ADS)
Su, Li-Chen; Chang, Ying-Feng; Li, Ying-Chang; Hsieh, Jo-Ping; Lee, Cheng-Chung; Chou, Chien
2010-08-01
In order to enhance the sensitivity of conventional rapid test technique for the detection of swine-origin influenza A (H1N1) viruses (S-OIVs), we used a paired surface plasma waves biosensor (PSPWB) based on SPR in conjunction with an optical heterodyne technique. Experimentally, PSPWB showed a 125-fold improvement at least in the S-OIV detection as compared to conventional enzyme linked immunosorbent assay. Moreover, the detection limit of the PSPWB for the S-OIV detection was enhanced 250-fold in buffer at least in comparison with that of conventional rapid influenza diagnostic test.
Li, Kemin; Yin, Rutie
2015-01-01
Abstract The aim of the present study was to determine the value of human papillomavirus (HPV) testing in screening patients with preinvasive cervical lesions. Seven hundred thirty-four women diagnosed with atypical squamous cells of undetermined significance (ASCUS+) cervical cytology during routine screening had additional cytologic testing and HPV DNA testing within 6 months of their diagnosis, after which all women who tested positive were referred for colposcopy and biopsy. The test findings were then used to determine the screening value of HPV for diagnosing preinvasive cervical lesions. Cytology and HPV testing were compared by conventional cytology. The odds ratio (OR) of sensitivity using ASCUS+ or low-grade squamous intraepithelial neoplasia (LSIL+) as a cutoff for detecting cervical intraepithelial neoplasia (CIN) II+ was, respectively, 0.78 (0.72, 0.85) and 0.82 (0.70, 0.95) (P < 0.01). The cytology for triage and conventional cytology had different sensitivities using ASCUS+ or LSIL+ as the cutoff (P < 0.01). The cytology or HPV testing and conventional cytology had a difference in sensitivity using ASCUS+, LSIL+, or high-grade squamous intraepithelial neoplasia (HSIL+) as the cutoff (P < 0.01). Cytology and HPV testing were also compared with conventional cytology. The OR of specificity using ASCUS+ or LSIL+ as the cutoff for the detection of CIN II+ was 1.97 (1.68, 2.31) and 1.10 (1.02, 1.18), respectively (P < 0.01). The cytology for triage and conventional cytology had a difference in specificity when ASCUS+ or LSIL+ was used as the cutoff (P < 0.01). Finally, the cytology or HPV testing and conventional cytology had a difference in specificity when ASCUS+, LSIL+, or HSIL+ was used as the cutoff (P < 0.01). Cytology and HPV testing and cytology for triage improved the specificity of detecting CIN II+, but this did not improve the sensitivity. Additionally, cytology or HPV testing improved the sensitivity of detecting CIN II+ but not the specificity. PMID:25654377
Zou, X H; Zhu, Y P; Ren, G Q; Li, G C; Zhang, J; Zou, L J; Feng, Z B; Li, B H
2017-02-20
Objective: To evaluate the significance of bacteria detection with filter paper method on diagnosis of diabetic foot wound infection. Methods: Eighteen patients with diabetic foot ulcer conforming to the study criteria were hospitalized in Liyuan Hospital Affiliated to Tongji Medical College of Huazhong University of Science and Technology from July 2014 to July 2015. Diabetic foot ulcer wounds were classified according to the University of Texas diabetic foot classification (hereinafter referred to as Texas grade) system, and general condition of patients with wounds in different Texas grade was compared. Exudate and tissue of wounds were obtained, and filter paper method and biopsy method were adopted to detect the bacteria of wounds of patients respectively. Filter paper method was regarded as the evaluation method, and biopsy method was regarded as the control method. The relevance, difference, and consistency of the detection results of two methods were tested. Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of filter paper method in bacteria detection were calculated. Receiver operating characteristic (ROC) curve was drawn based on the specificity and sensitivity of filter paper method in bacteria detection of 18 patients to predict the detection effect of the method. Data were processed with one-way analysis of variance and Fisher's exact test. In patients tested positive for bacteria by biopsy method, the correlation between bacteria number detected by biopsy method and that by filter paper method was analyzed with Pearson correlation analysis. Results: (1) There were no statistically significant differences among patients with wounds in Texas grade 1, 2, and 3 in age, duration of diabetes, duration of wound, wound area, ankle brachial index, glycosylated hemoglobin, fasting blood sugar, blood platelet count, erythrocyte sedimentation rate, C-reactive protein, aspartate aminotransferase, serum creatinine, and urea nitrogen (with F values from 0.029 to 2.916, P values above 0.05), while there were statistically significant differences among patients with wounds in Texas grade 1, 2, and 3 in white blood cell count and alanine aminotransferase (with F values 4.688 and 6.833 respectively, P <0.05 or P <0.01). (2) According to the results of biopsy method, 6 patients were tested negative for bacteria, and 12 patients were tested positive for bacteria, among which 10 patients were with bacterial number above 1×10(5)/g, and 2 patients with bacterial number below 1×10(5)/g. According to the results of filter paper method, 8 patients were tested negative for bacteria, and 10 patients were tested positive for bacteria, among which 7 patients were with bacterial number above 1×10(5)/g, and 3 patients with bacterial number below 1×10(5)/g. There were 7 patients tested positive for bacteria both by biopsy method and filter paper method, 8 patients tested negative for bacteria both by biopsy method and filter paper method, and 3 patients tested positive for bacteria by biopsy method but negative by filter paper method. Patients tested negative for bacteria by biopsy method did not tested positive for bacteria by filter paper method. There was directional association between the detection results of two methods ( P =0.004), i. e. if result of biopsy method was positive, result of filter paper method could also be positive. There was no obvious difference in the detection results of two methods ( P =0.250). The consistency between the detection results of two methods was ordinary (Kappa=0.68, P =0.002). (3) The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of filter paper method in bacteria detection were 70%, 100%, 1.00, 0.73, and 83.3%, respectively. Total area under ROC curve of bacteria detection by filter paper method in 18 patients was 0.919 (with 95% confidence interval 0-1.000, P =0.030). (4) There were 13 strains of bacteria detected by biopsy method, with 5 strains of Acinetobacter baumannii, 5 strains of Staphylococcus aureus, 1 strain of Pseudomonas aeruginosa, 1 strain of Streptococcus bovis, and 1 strain of bird Enterococcus . There were 11 strains of bacteria detected by filter paper method, with 5 strains of Acinetobacter baumannii, 3 strains of Staphylococcus aureus, 1 strain of Pseudomonas aeruginosa, 1 strain of Streptococcus bovis, and 1 strain of bird Enterococcus . Except for Staphylococcus aureus, the sensitivity and specificity of filter paper method in the detection of the other 4 bacteria were all 100%. The consistency between filter paper method and biopsy method in detecting Acinetobacter baumannii was good (Kappa=1.00, P <0.01), while that in detecting Staphylococcus aureus was ordinary (Kappa=0.68, P <0.05). (5) There was no obvious correlation between the bacteria number of wounds detected by filter paper method and that by biopsy method ( r =0.257, P =0.419). There was obvious correlation between the bacteria numbers detected by two methods in wounds with Texas grade 1 and 2 (with r values as 0.999, P values as 0.001). There was no obvious correlation between the bacteria numbers detected by two methods in wounds with Texas grade 3 ( r =-0.053, P =0.947). Conclusions: The detection result of filter paper method is in accordance with that of biopsy method in the determination of bacterial infection, and it is of great importance in the diagnosis of local infection of diabetic foot wound.
Computer-Detected Attention Affects Foreign Language Listening but Not Reading Performance.
Lee, Shu-Ping
2016-08-01
No quantitative study has explored the influence of attention on learning English as a foreign language (EFL). This study investigated whether computer-detected attention is associated with EFL reading and listening and reading and listening anxiety. Traditional paper-based English tests used as entrance examinations and tests of general trait anxiety, reading, listening, reading test state anxiety, and listening test state anxiety were administered in 252 Taiwan EFL college students who were divided into High Attention (Conners' Continuous Performance Test, CPT < 50) and Low Attention (CPT ≥ 50) groups. No differences were found between the two groups for traditional paper-based English tests, trait anxieties, general English reading anxiety scales, and general English listening anxiety scales. The Low Attention group had higher test state anxiety and lower listening test scores than the High Attention group, but not in reading. State anxiety during listening tests for EFL students with computer-detected low attention tendency was elevated and their EFL listening performance was affected, but those differences were not found in reading. © The Author(s) 2016.
Automatic laser beam alignment using blob detection for an environment monitoring spectroscopy
NASA Astrophysics Data System (ADS)
Khidir, Jarjees; Chen, Youhua; Anderson, Gary
2013-05-01
This paper describes a fully automated system to align an infra-red laser beam with a small retro-reflector over a wide range of distances. The component development and test were especially used for an open-path spectrometer gas detection system. Using blob detection under OpenCV library, an automatic alignment algorithm was designed to achieve fast and accurate target detection in a complex background environment. Test results are presented to show that the proposed algorithm has been successfully applied to various target distances and environment conditions.
ERIC Educational Resources Information Center
Jak, Suzanne; Oort, Frans J.; Dolan, Conor V.
2013-01-01
We present a test for cluster bias, which can be used to detect violations of measurement invariance across clusters in 2-level data. We show how measurement invariance assumptions across clusters imply measurement invariance across levels in a 2-level factor model. Cluster bias is investigated by testing whether the within-level factor loadings…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Burrows, T.A.; Thoma, P.J.
Two types of ion-mobility detectors were evaluated in both laboratory and field tests. Laboratory test results show that these detectors are highly sensitive to dynamite and pistol powder and have good false-alarm agent rejection. Field tests of these two detectors revealed that they would detect dynamite and Ball-C-Propellent in free air. However, neither of the ion-mobility detectors would detect these explosives if the explosives were concealed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cester, D.; Lunardon, M.; Stevanato, L.
2015-07-01
MODES SNM project aimed to carry out technical research in order to develop a prototype for a mobile, modular detection system for radioactive sources and Special Nuclear Materials (SNM). Its main goal was to deliver a tested prototype of a modular mobile system capable of passively detecting weak or shielded radioactive sources with accuracy higher than that of currently available systems. By the end of the project all the objectives have been successfully achieved. Results from the laboratory commissioning and the field tests will be presented. (authors)
Horng, Yu-Tze; Soo, Po-Chi; Shen, Bin-Jon; Hung, Yu-Li; Lo, Kai-Yin; Su, Hsun-Pi; Wei, Jun-Rong; Hsieh, Shang-Chen; Hsueh, Po-Ren; Lai, Hsin-Chih
2006-06-01
A novelly improved polymerase chian reaction and immunochromatography test (PCR-ICT) hybrid assay comprising traditional multiplex-nested PCR and ICT, (a lateral-flow device) was developed for direct detection of Legionella bacteria from environmental cooling tower samples. The partial 16S rDNA (specific for Legionella spp.) and dnaJ (specific for Legionella pneumophila) genes from Legionella chromosome were first specifically amplified by multiplex-nested PCR, respectively, followed by detection using ICT strip. Reading of results was based on presence or absence of the two test lines on the strips. Presence of test line 1 indicated existence of Legionella spp. specific 16S rDNA and identified Legionella spp. Presence of test line 2 further indicated existence of dnaJ and thus specifically identified L. pneumophila. In contrast, for non-Legionellae bacteria no test line formation was observed. Results of direct detection of Legionella bacteria and L. pneumophila from water tower specimens by this assay showed 100% sensitivity, and 96.6% and 100% specificity, respectively compared with traditional culture, biochemical and serological identification methods. The PCR-ICT hybrid assay does not require sophisticated equipment and was proved to be practically useful in rapid and direct Legionellae detection from environmental water samples.
Phenotypic detection of broad-spectrum beta-lactamases in microbiological practice.
Htoutou Sedlakova, Miroslava; Hanulik, Vojtech; Chroma, Magdalena; Hricova, Kristyna; Kolar, Milan; Latal, Tomas; Schaumann, Reiner; Rodloff, Arne C
2011-05-01
Enterobacteriaceae producing ESBL and AmpC enzymes can be associated with failure of antibiotic therapy and related morbidity and mortality. Their routine detection in microbiology laboratories is still a problem. The aim of this study was to compare the sensitivity of selected phenotypic methods. A total of 106 strains of the Enterobacteriaceae family were tested, in which molecular biology methods confirmed the presence of genes encoding ESBL or AmpC. In ESBL-positive strains, the sensitivity of the ESBL Etest (AB Biodisk) and a modified double-disk synergy test (DDST) were evaluated. AmpC strains were tested by a modified AmpC disk method using 3-aminophenylboronic acid. For simultaneous detection of ESBL and AmpC, the microdilution method with a modified set of antimicrobial agents was used. The sensitivity of the ESBL Etest was 95%; the modified DDST yielded 100% sensitivity for ESBL producers and the AmpC test correctly detected 95% of AmpC-positive strains. The sensitivity of the modified microdilution method was 87% and 95% for ESBL and AmpC beta lactamases, respectively. The detection of ESBL and AmpC beta lactamases should be based on specific phenotypic methods such as the modified DDST, ESBL Etest, AmpC disk test and the modified microdilution method.
Phenotypic detection of broad-spectrum beta-lactamases in microbiological practice
Sedlakova, Miroslava Htoutou; Hanulik, Vojtech; Chroma, Magdalena; Hricova, Kristyna; Kolar, Milan; Latal, Tomas; Schaumann, Reiner; Rodloff, Arne C.
2011-01-01
Summary Background Enterobacteriaceae producing ESBL and AmpC enzymes can be associated with failure of antibiotic therapy and related morbidity and mortality. Their routine detection in microbiology laboratories is still a problem. The aim of this study was to compare the sensitivity of selected phenotypic methods. Material/Methods A total of 106 strains of the Enterobacteriaceae family were tested, in which molecular biology methods confirmed the presence of genes encoding ESBL or AmpC. In ESBL-positive strains, the sensitivity of the ESBL Etest (AB Biodisk) and a modified double-disk synergy test (DDST) were evaluated. AmpC strains were tested by a modified AmpC disk method using 3-aminophenylboronic acid. For simultaneous detection of ESBL and AmpC, the microdilution method with a modified set of antimicrobial agents was used. Results The sensitivity of the ESBL Etest was 95%; the modified DDST yielded 100% sensitivity for ESBL producers and the AmpC test correctly detected 95% of AmpC-positive strains. The sensitivity of the modified microdilution method was 87% and 95% for ESBL and AmpC beta lactamases, respectively. Conclusions The detection of ESBL and AmpC beta lactamases should be based on specific phenotypic methods such as the modified DDST, ESBL Etest, AmpC disk test and the modified microdilution method. PMID:21525803
Tapered Roller Bearing Damage Detection Using Decision Fusion Analysis
NASA Technical Reports Server (NTRS)
Dempsey, Paula J.; Kreider, Gary; Fichter, Thomas
2006-01-01
A diagnostic tool was developed for detecting fatigue damage of tapered roller bearings. Tapered roller bearings are used in helicopter transmissions and have potential for use in high bypass advanced gas turbine aircraft engines. A diagnostic tool was developed and evaluated experimentally by collecting oil debris data from failure progression tests conducted using health monitoring hardware. Failure progression tests were performed with tapered roller bearings under simulated engine load conditions. Tests were performed on one healthy bearing and three pre-damaged bearings. During each test, data from an on-line, in-line, inductance type oil debris sensor and three accelerometers were monitored and recorded for the occurrence of bearing failure. The bearing was removed and inspected periodically for damage progression throughout testing. Using data fusion techniques, two different monitoring technologies, oil debris analysis and vibration, were integrated into a health monitoring system for detecting bearing surface fatigue pitting damage. The data fusion diagnostic tool was evaluated during bearing failure progression tests under simulated engine load conditions. This integrated system showed improved detection of fatigue damage and health assessment of the tapered roller bearings as compared to using individual health monitoring technologies.
[Clinical microbiology laboratory and imported parasitic diseases].
Martín-Rabadán, Pablo; Martínez-Ruiz, Rocío; Cuadros, Juan; Cañavate, Carmen
2010-12-01
Imported parasitosis represents an increasingly frequent diagnostic challenge for microbiology laboratories. A surge in immigration and international travel has led to a rise in the number of imported cases of parasitosis, and this trend is expected to continue in the future. The present article addresses this challenge by reviewing recommended diagnostic approaches and tests. Currently, microscopy is always recommended when analysing blood samples for parasites. If malaria is suspected, rapid antigen testing (including at least HRP2 antigen) should also be performed. The work-up for suspected leishmaniasis should include serology, culture, and in selected cases detection of antigen in urine. In suspected Chagas disease, two different serological tests should be performed. PCR for blood protozoa is highly sensitive, although it cannot be used to rule out Chagas disease, since this condition may be present without parasitemia. Accurate diagnosis of intestinal amebiasis usually requires PCR or antigen detection tests. In helminthiasis, traditional microscopy may need to be complemented with other tests, such as agar plate culture for strongyloidiasis, Og4C3 antigen detection for bancroftian filariasis, and antibody detection test for filariasis and schistosomiasis. Copyright © 2010 Elsevier España, S.L. All rights reserved.
Shivakiran, M S; Venkataramana, M; Lakshmana Rao, P V
2016-01-01
Dipicolinic acid (DPA) is an important chemical marker for the detection of bacterial spores. In this study, complexes of lanthanide series elements such as erbium, europium, neodymium, and terbium were prepared with pyrocatechol violet and effectively immobilized the pyrocatechol violet (PV)-metal complex on a filter paper using polyvinyl alcohol. These filter paper strips were employed for the onsite detection of bacterial spores. The test filter papers were evaluated quantitatively with different concentrations of DPA and spores of various bacteria. Among the four lanthanide ions, erbium displayed better sensitivity than the other ions. The limit of detection of this test for DPA was 60 μM and 5 × 10(6) spores. The effect of other non-spore-forming bacteria and interfering chemicals on the test strips was also evaluated. The non-spore-forming bacteria did not have considerable effect on the test strip whereas chemicals such as EDTA had significant effects on the test results. The present test is rapid and robust, capable of providing timely results for better judgement to save resources on unnecessary decontamination procedures during false alarms.
2014-01-01
Background Pyrogen detection is of utmost importance in pharmaceutical industry, laboratories and health care institutions. As an alternative to the animal-consuming rabbit pyrogen test or Limulus amoebocyte lysate test, the monocyte activation test was introduced as a gold standard method in the European Pharmacopoeia. However, the monocyte activation test has not gained wide acceptance in practice. Methods We stimulated bovine whole blood with different endotoxin preparations (lipopolysaccharide E.coli 0127:B8 and 0113:H10), as well as the non-endotoxin pyrogens peptidoglycan and lipoteichoic acid. Prostaglandin E2 (PGE2) served as read out. Results Employing PGE2 as read out enabled detection limits of 0.04 EU/ml for lipopolysaccharide 0127:B8, 0.25 EU/ml for lipopolysaccharide 0113:H10 and 10 μg/ml of lipoteichoic acid as well as peptidoglycan. To evaluate the bWBA test system as a possible alternative to the MAT we performed a peer-to-peer comparison of the two methods and confirmed similar sensitivities. Conclusions In conclusion, the bovine whole blood assay (bWBA) reproducibly enabled sensitive detection of endotoxin and non-endotoxin pyrogens and may thus become a viable alternative for pyrogen testing. PMID:25209100
Sample-to-answer palm-sized nucleic acid testing device towards low-cost malaria mass screening.
Choi, Gihoon; Prince, Theodore; Miao, Jun; Cui, Liwang; Guan, Weihua
2018-05-19
The effectiveness of malaria screening and treatment highly depends on the low-cost access to the highly sensitive and specific malaria test. We report a real-time fluorescence nucleic acid testing device for malaria field detection with automated and scalable sample preparation capability. The device consists a compact analyzer and a disposable microfluidic reagent compact disc. The parasite DNA sample preparation and subsequent real-time LAMP detection were seamlessly integrated on a single microfluidic compact disc, driven by energy efficient non-centrifuge based magnetic field interactions. Each disc contains four parallel testing units which could be configured either as four identical tests or as four species-specific tests. When configured as species-specific tests, it could identify two of the most life-threatening malaria species (P. falciparum and P. vivax). The NAT device is capable of processing four samples simultaneously within 50 min turnaround time. It achieves a detection limit of ~0.5 parasites/µl for whole blood, sufficient for detecting asymptomatic parasite carriers. The combination of the sensitivity, specificity, cost, and scalable sample preparation suggests the real-time fluorescence LAMP device could be particularly useful for malaria screening in the field settings. Copyright © 2018 Elsevier B.V. All rights reserved.
Advances in Candida detection platforms for clinical and point-of-care applications
Safavieh, Mohammadali; Coarsey, Chad; Esiobu, Nwadiuto; Memic, Adnan; Vyas, Jatin Mahesh; Shafiee, Hadi; Asghar, Waseem
2016-01-01
Invasive candidiasis remains one of the most serious community and healthcare-acquired infections worldwide. Conventional Candida detection methods based on blood and plate culture are time-consuming and require at least 2–4 days to identify various Candida species. Despite considerable advances for candidiasis detection, the development of simple, compact and portable point-of-care diagnostics for rapid and precise testing that automatically performs cell lysis, nucleic acid extraction, purification and detection still remains a challenge. Here, we systematically review most prominent conventional and nonconventional techniques for the detection of various Candida species, including Candida staining, blood culture, serological testing and nucleic acid-based analysis. We also discuss the most advanced lab on a chip devices for candida detection. PMID:27093473
Lu, Xujin; Lloyd, David K; Klohr, Steven E
2016-01-01
A feasibility study was conducted for a sensitive and robust dye immersion method for the measurement of container closure integrity of unopened prefilled syringes using fluorescence spectrophotometry as the detection method. A Varian Cary Eclipse spectrofluorometer was used with a custom-made sample holder to position the intact syringe in the sample compartment for fluorescence measurements. Methylene blue solution was initially evaluated as the fluorophore in a syringe with excitation at 607 nm and emission at 682 nm, which generated a limit of detection of 0.05 μg/mL. Further studies were conducted using rhodamine 123, a dye with stronger fluorescence. Using 480 nm excitation and 525 nm emission, the dye in the syringe could be easily detected at levels as low as 0.001 μg/mL. The relative standard deviation for 10 measurements of a sample of 0.005 μg/mL (with repositioning of the syringe after each measurement) was less than 1.1%. A number of operational parameters were optimized, including the photomultiplier tube voltage, excitation, and emission slit widths. The specificity of the testing was challenged by using marketed drug products and a protein sample, which showed no interference to the rhodamine detection. Results obtained from this study demonstrated that using rhodamine 123 for container closure integrity testing with in-situ (in-syringe) fluorescence measurements significantly enhanced the sensitivity and robustness of the testing and effectively overcame limitations of the traditional methylene blue method with visual or UV-visible absorption detection. Ensuring container closure integrity of injectable pharmaceutical products is necessary to maintain quality throughout the shelf life of a sterile drug product. Container closure integrity testing has routinely been used to evaluate closure integrity during product development and production line qualification of prefilled syringes, vials, and devices. However, container closure integrity testing has recently gained industry attention due to increased regulatory agency scrutiny regarding the analytical rigor of container closure integrity testing methods and expectations to use container closure integrity testing in lieu of sterility tests in stability programs. Methylene blue dye is often used for dye ingress testing of container closure integrity, but we found it unsuitable for reliable detection of small breaches in prefilled syringes of drug product. This work describes the suitability and advantages of using a fluorescent dye and spectroscopic detection for a robust, sensitive, and quality control-friendly container closure integrity testing method for prefilled syringes. © PDA, Inc. 2016.
Detection of Oil in Water Column, Final Report: Detection Prototype Tests
2014-07-01
first phase of the project involved initial development and testing of three technologies to address the detection problem . This second phase...important oceanic phenomena such as density stratification and naturally occurring particulate matter, which will affect the performance of sensors in the ...2 UNCLAS//Public | CG-926 RDC | M. Fitzpatrick, et al.| Public July 2014 spills of submerged oil is far more complex due to the problems
Method of Fault Detection and Rerouting
NASA Technical Reports Server (NTRS)
Gibson, Tracy L. (Inventor); Medelius, Pedro J. (Inventor); Lewis, Mark E. (Inventor)
2013-01-01
A system and method for detecting damage in an electrical wire, including delivering at least one test electrical signal to an outer electrically conductive material in a continuous or non-continuous layer covering an electrically insulative material layer that covers an electrically conductive wire core. Detecting the test electrical signals in the outer conductive material layer to obtain data that is processed to identify damage in the outer electrically conductive material layer.
Schramm, Elisabeth; Kürten, Andreas; Hölzer, Jasper; Mitschke, Stefan; Mühlberger, Fabian; Sklorz, Martin; Wieser, Jochen; Ulrich, Andreas; Pütz, Michael; Schulte-Ladbeck, Rasmus; Schultze, Rainer; Curtius, Joachim; Borrmann, Stephan; Zimmermann, Ralf
2009-06-01
An in-house-built ion trap mass spectrometer combined with a soft ionization source has been set up and tested. As ionization source, an electron beam pumped vacuum UV (VUV) excimer lamp (EBEL) was used for single-photon ionization. It was shown that soft ionization allows the reduction of fragmentation of the target analytes and the suppression of most matrix components. Therefore, the combination of photon ionization with the tandem mass spectrometry (MS/MS) capability of an ion trap yields a powerful tool for molecular ion peak detection and identification of organic trace compounds in complex matrixes. This setup was successfully tested for two different applications. The first one is the detection of security-relevant substances like explosives, narcotics, and chemical warfare agents. One test substance from each of these groups was chosen and detected successfully with single photon ionization ion trap mass spectrometry (SPI-ITMS) MS/MS measurements. Additionally, first tests were performed, demonstrating that this method is not influenced by matrix compounds. The second field of application is the detection of process gases. Here, exhaust gas from coffee roasting was analyzed in real time, and some of its compounds were identified using MS/MS studies.
Scharinger, Eva J.; Dietrich, Richard; Wittwer, Tobias; Märtlbauer, Erwin; Schauer, Kristina
2017-01-01
The ubiquitous and opportunistic pathogen Cronobacter sakazakii is responsible for severe meningitis, sepsis, and necrotizing enterocolitis in neonates and infants associated with ingestion of contaminated powdered infant formula (PIF). The current ISO method for isolation and detection of Cronobacter spp. is laborious, time-consuming and expensive. In this study, a multiplexed lateral flow test strip was developed to rapidly detect and simultaneously serotype O1 and O2 C. sakazakii serotypes. The assay is based on two monoclonal antibodies (MAb) that specifically bind to the lipopolysaccharides (LPS) of these pathogens. The test strip provides results very quickly; C. sakazakii could be detected in pure culture within 15 min with a sensitivity of 107 CFU/ml. After non-selective enrichment for 18 h as low as one Cronobacter cell per g PIF could be detected. Moreover, the established lateral flow assay (LFA) offers excellent specificity showing no cross-reactivity with other C. sakazakii serotypes, Cronobacter species or Enterobacteriaceae tested. These characteristics, together with several advantages such as speed, simplicity in performance, low analysis cost, and no requirement of specialized skills or sophisticated equipment make the developed multiplexed LFA suitable for reliable detection and serotyping of C. sakazakii serotypes O1 and O2. PMID:28979257
Scharinger, Eva J; Dietrich, Richard; Wittwer, Tobias; Märtlbauer, Erwin; Schauer, Kristina
2017-01-01
The ubiquitous and opportunistic pathogen Cronobacter sakazakii is responsible for severe meningitis, sepsis, and necrotizing enterocolitis in neonates and infants associated with ingestion of contaminated powdered infant formula (PIF). The current ISO method for isolation and detection of Cronobacter spp. is laborious, time-consuming and expensive. In this study, a multiplexed lateral flow test strip was developed to rapidly detect and simultaneously serotype O1 and O2 C. sakazakii serotypes. The assay is based on two monoclonal antibodies (MAb) that specifically bind to the lipopolysaccharides (LPS) of these pathogens. The test strip provides results very quickly; C. sakazakii could be detected in pure culture within 15 min with a sensitivity of 10 7 CFU/ml. After non-selective enrichment for 18 h as low as one Cronobacter cell per g PIF could be detected. Moreover, the established lateral flow assay (LFA) offers excellent specificity showing no cross-reactivity with other C. sakazakii serotypes, Cronobacter species or Enterobacteriaceae tested. These characteristics, together with several advantages such as speed, simplicity in performance, low analysis cost, and no requirement of specialized skills or sophisticated equipment make the developed multiplexed LFA suitable for reliable detection and serotyping of C. sakazakii serotypes O1 and O2.
Pritt, Bobbi S; Patel, Robin; Kirn, Thomas J; Thomson, Richard B
2016-10-01
Nucleic acid amplification tests (NAATs) have frequently been the standard diagnostic approach when specific infectious agents are sought in a clinic specimen. They can be applied for specific agents such as S. pyogenes, or commercial multiplex NAATs for detection of a variety of pathogens in gastrointestinal, bloodstream, and respiratory infections may be used. NAATs are both rapid and sensitive. For many years, S. pyogenes testing algorithms used a rapid and specific group A streptococcal antigen test to screen throat specimens, followed, in some clinical settings, by a throat culture for S. pyogenes to increase the sensitivity of its detection. Now S. pyogenes NAATs are being used with increasing frequency. Given their accuracy, rapidity, and ease of use, should they replace antigen detection and culture for the detection of bacterial pharyngitis? Bobbi Pritt and Robin Patel of the Mayo Clinic, where S. pyogenes NAATs have been used for well over a decade with great success, will explain the advantages of this approach, while Richard (Tom) Thomson and Tom Kirn of the NorthShore University HealthSystem will discuss their concerns about this approach to diagnosing bacterial pharyngitis. Copyright © 2016, American Society for Microbiology. All Rights Reserved.
Wang, Qin; Zhang, Yong; Nie, Kai; Wang, Huanyu; Du, Haijun; Song, Jingdong; Xiao, Kang; Lei, Wenwen; Guo, Jianqiang; Wei, Hejiang; Cai, Kun; Wang, Yanhai; Wu, Jiang; Gerald, Bangura; Kamara, Idrissa Laybohr; Liang, Mifang; Wu, Guizhen; Dong, Xiaoping
2016-03-01
The quality control process throughout the Ebola virus nucleic acid detection in Sierra Leone-China Friendship Biological Safety Laboratory (SLE-CHN Biosafety Lab) was described in detail, in order to comprehensively display the scientific, rigorous, accurate and efficient practice in detection of Ebola virus of first batch detection team in SLE-CHN Biosafety Lab. Firstly, the key points of laboratory quality control system was described, including the managements and organizing, quality control documents and information management, instrument, reagents and supplies, assessment, facilities design and space allocation, laboratory maintenance and biosecurity. Secondly, the application of quality control methods in the whole process of the Ebola virus detection, including before the test, during the test and after the test, was analyzed. The excellent and professional laboratory staffs, the implementation of humanized management are the cornerstone of the success; High-level biological safety protection is the premise for effective quality control and completion of Ebola virus detection tasks. And professional logistics is prerequisite for launching the laboratory diagnosis of Ebola virus. The establishment and running of SLE-CHN Biosafety Lab has landmark significance for the friendship between Sierra Leone and China, and the lab becomes the most important base for Ebola virus laboratory testing in Sierra Leone.
Paper analytical devices for detection of low-quality pharmaceuticals
NASA Astrophysics Data System (ADS)
Weaver, A.; Lieberman, M.
2014-03-01
There is currently no global screening system to detect low quality pharmaceuticals, despite widespread recognition of the public health problems caused by substandard and falsified medicines. In order to fill this void, we designed a rapid field screening test that is interfaced with the mobile phone network. The user scrapes a pill over several reaction areas on a paper test card, and then dips one edge of the card into water to activate dried reagents stored on the paper. These reagents carry out multiple color tests and result in a pattern of colored stripes that give information about the chemical content of the pill. The test cards are inexpensive and instrument-free, and we think they will be a scalable testing option in low resource settings. Studies on falsified drugs archived at the FDA show that the test cards are effective at detecting a wide variety of low-quality formulations of many classes of pharmaceuticals, and field tests are currently under way in Kenya.
Wolf, B H; Weening, R S; Schutgens, R B; van Noorden, C J; Vogels, I M; Nagelkerke, N J
1987-09-30
The results of a quantitative spectrophotometric enzyme assay, a fluorescent spot test and a cytochemical assay for glucose-6-phosphate dehydrogenase deficiency were compared systematically. The high sensitivity of the spectrophotometric assay and the fluorescent spot test in the detection of severely deficient individuals was confirmed. For the detection of heterozygote females, however both tests were unreliable; the sensitivities of the fluorescent spot test and the spectrophotometric assay being 32% and 11% respectively. Specificities for both tests were high (99%). Introduction of the ratio of glucose-6-phosphate dehydrogenase and pyruvate kinase (G-6-PD/PK ratio) activities increased the sensitivity of the spectrophotometric assay to nearly 100%. It is concluded that the fluorescent spot test should be used for the diagnosis of G-6-PD deficiency in developing countries; whereas if spectrophotometric enzyme assays are available, the G-6-PD/PK ratio should always be performed. In cases where the ratio is less than 0.70, cytochemical analysis is indicated.
Evaluation of a rapid immunodiagnostic test kit for rabies virus.
Kang, BoKyu; Oh, JinSik; Lee, ChulSeung; Park, Bong-Kyun; Park, YoungNam; Hong, KyungSoo; Lee, KyungGi; Cho, ByungKi; Song, DaeSub
2007-10-01
A rapid immunodiagnostic test kit for rabies virus detection was evaluated using 51 clinical samples and 4 isolates of rabies virus. The quick detection of rabies virus under field conditions may be helpful in determining if post-exposure prophylaxis is needed, thereby avoiding unnecessary treatments, as well as undue economic burden. There are several widely used diagnostic methods for rabies, including fluorescent antibody tests, reverse transcription polymerase chain reaction, and electron microscopy; however, these methods include time-consuming, intricate, and costly procedures. The rapid immunodiagnostic test was able to detect rabies virus in clinical samples, including brain tissue and saliva, in addition to 10(3.2) 50% lethal dose (LD(50))/mL cell-adapted rabies virus. The assay was not cross-reactive with non-rabies virus microbes. When the performance of the rapid immunodiagnostic test was compared to a fluorescent antibody test, the rapid immunodiagnostic test had a sensitivity of 91.7% and specificity of 100% (95.8% CI).
Ford, George A; Denniston, Sara; Sesser, David; Skeels, Michael R; LaFranchi, Stephen H
2016-01-01
The newborn screening (NBS) program in Oregon, USA, collects two routine specimens in all infants. The aim of our study was to determine the incidence of permanent versus transient congenital hypothyroidism (CH) in infants detected on the first versus second screening test. Thyroid function was determined in infants after the age of 3 years diagnosed with CH and born in Oregon between 2005 and 2011. Permanent hypothyroidism was defined as a TSH rise >10 mIU/ml after the first year on treatment or a TSH rise >6 mIU/ml with temporary discontinuation of l-thyroxine after the age of 3 years. Of the cases detected on the first test, 72 of 87 (83%) were permanent and 15 of 87 (17%) were transient, while of the cases detected on the second test, 5 of 22 (23%) were permanent and 17 of 22 (77%) were transient (OR 16.3, p < 0.001). There was a female preponderance detected on the first screen versus a male preponderance on the second screen. Blood spot and serum thyroid function tests at diagnosis, before treatment, were not meaningfully different between the two groups. The mean l-thyroxine dose at the age of 3 years was greater on the first screen: 61.2 versus 36.6 μg/day. Infants detected on the second NBS specimen have a higher incidence of transient CH. © 2016 S. Karger AG, Basel.
Rapid detection of fumonisin B1 using a colloidal gold immunoassay strip test in corn samples.
Ling, Sumei; Wang, Rongzhi; Gu, Xiaosong; Wen, Can; Chen, Lingling; Chen, Zhibin; Chen, Qing-Ai; Xiao, Shiwei; Yang, Yanling; Zhuang, Zhenhong; Wang, Shihua
2015-12-15
Fumonisin B1 (FB1) is the most common and highest toxic of fumonisins species, exists frequently in corn and corn-based foods, leading to several animal and human diseases. Furthermore, FB1 was reported that it was associated with the human esophageal cancer. In view of the harmful of FB1, it is urgent to develop a feasible and accuracy method for rapid detection of FB1. In this study, a competitive immunoassay for FB1 detection was developed based on colloidal gold-antibody conjugate. The FB1-keyhole limpet hemoeyanin (FB1-KLH) conjugate was embedded in the test line, and goat anti-mouse IgG antibody embedded in the control line. The color density of the test line correlated with the concentration of FB1 in the range from 2.5 to 10 ng/mL, and the visual limit detection of test for FB1 was 2.5 ng/mL. The results indicated that the test strip is specific for FB1, and no cross-reactivity to other toxins. The quantitative detection for FB1 was simple, only needing one step without complicated assay performance and expensive equipment, and the total time of visual evaluation was less than 5 min. Hence, the developed colloidal gold-antibody assay can be used as a feasible method for FB1 rapid and quantitative detection in corn samples. Copyright © 2015 Elsevier Ltd. All rights reserved.
Muñoz, Constanza; Zumarán, Cecilia; González, Tamara; Wozniak, Aniela; Castillo, Claudia; García, Patricia
2017-08-01
The detection of carbapenemase-producing gram negative bacilli is complicated, because there are available multiple options of test. The confirmation of the enzyme by molecular characterization is not available in all laboratories in our country. To propose a fast, efficient and simple strategy to detect and confirm CPB. 39 CPB isolates and 8 non-producing were used to evaluate the phenotypic test Carba NP, CarbAcineto NP and Blue-Carba, validating the test Xpert® Carba-R, to be used directly with bacterial colonies with conventional PCR. The sensitivity of Carba NP, CarbAcineto NP and Blue-Carba was 79,5; 87,2 y 84,6%, respectively; and specificity was 79.5; 87.2 and 84.6%, respectively. The limit of detection of Xpert® Carba-R was different for each carbapenemasa: 40.8 ufc/reaction to KPC and NDM and 30.6 ufc/reaction to VIM. On isolates with decreased susceptibility to carbapenems we propose to use as screening the test CarbAcineto NP, follow by Xpert®Carba-R to characterize the carbapenemase and adopt specific infection control measures.
Caviedes, Luz; Lee, Tien-Shun; Gilman, Robert H.; Sheen, Patricia; Spellman, Emily; Lee, Ellen H.; Berg, Douglas E.; Montenegro-James, Sonia
2000-01-01
Inexpensive, rapid, and reliable methods of detecting infection by and drug susceptibility of Mycobacterium tuberculosis (MTB) are crucial to the control of tuberculosis. The novel microscopic observation broth-drug susceptibility assay (MODS) detects early growth of MTB in liquid medium, allowing more timely diagnosis and drug susceptibility testing. Sputum samples from hospitalized patients in Peru were analyzed by using stains, culture, and PCR. Sensitivity of MODS (92%) compared favorably with the most sensitive of the other culture methods (93%). Sputum samples positive for tuberculosis were tested for susceptibility to isoniazid and rifampin with the microwell alamar blue assay (MABA) and MODS. In 89% of cases, there was concordance between MODS and MABA. Of the diagnostic and susceptibility testing methods used, MODS yielded results most rapidly (median, 9.0 and 9.5 days, respectively). MODS is a rapid, inexpensive, sensitive, and specific method for MTB detection and susceptibility testing; it is particularly appropriate for use in developing countries burdened by significant infection rates and increasing numbers of multiple-drug-resistant cases. PMID:10699023
Caviedes, L; Lee, T S; Gilman, R H; Sheen, P; Spellman, E; Lee, E H; Berg, D E; Montenegro-James, S
2000-03-01
Inexpensive, rapid, and reliable methods of detecting infection by and drug susceptibility of Mycobacterium tuberculosis (MTB) are crucial to the control of tuberculosis. The novel microscopic observation broth-drug susceptibility assay (MODS) detects early growth of MTB in liquid medium, allowing more timely diagnosis and drug susceptibility testing. Sputum samples from hospitalized patients in Peru were analyzed by using stains, culture, and PCR. Sensitivity of MODS (92%) compared favorably with the most sensitive of the other culture methods (93%). Sputum samples positive for tuberculosis were tested for susceptibility to isoniazid and rifampin with the microwell alamar blue assay (MABA) and MODS. In 89% of cases, there was concordance between MODS and MABA. Of the diagnostic and susceptibility testing methods used, MODS yielded results most rapidly (median, 9.0 and 9.5 days, respectively). MODS is a rapid, inexpensive, sensitive, and specific method for MTB detection and susceptibility testing; it is particularly appropriate for use in developing countries burdened by significant infection rates and increasing numbers of multiple-drug-resistant cases.
NASA Technical Reports Server (NTRS)
1985-01-01
The primary objective of the Test Active Control Technology (ACT) System laboratory tests was to verify and validate the system concept, hardware, and software. The initial lab tests were open loop hardware tests of the Test ACT System as designed and built. During the course of the testing, minor problems were uncovered and corrected. Major software tests were run. The initial software testing was also open loop. These tests examined pitch control laws, wing load alleviation, signal selection/fault detection (SSFD), and output management. The Test ACT System was modified to interface with the direct drive valve (DDV) modules. The initial testing identified problem areas with DDV nonlinearities, valve friction induced limit cycling, DDV control loop instability, and channel command mismatch. The other DDV issue investigated was the ability to detect and isolate failures. Some simple schemes for failure detection were tested but were not completely satisfactory. The Test ACT System architecture continues to appear promising for ACT/FBW applications in systems that must be immune to worst case generic digital faults, and be able to tolerate two sequential nongeneric faults with no reduction in performance. The challenge in such an implementation would be to keep the analog element sufficiently simple to achieve the necessary reliability.
Memory Detection 2.0: The First Web-Based Memory Detection Test
Kleinberg, Bennett; Verschuere, Bruno
2015-01-01
There is accumulating evidence that reaction times (RTs) can be used to detect recognition of critical (e.g., crime) information. A limitation of this research base is its reliance upon small samples (average n = 24), and indications of publication bias. To advance RT-based memory detection, we report upon the development of the first web-based memory detection test. Participants in this research (Study1: n = 255; Study2: n = 262) tried to hide 2 high salient (birthday, country of origin) and 2 low salient (favourite colour, favourite animal) autobiographical details. RTs allowed to detect concealed autobiographical information, and this, as predicted, more successfully so than error rates, and for high salient than for low salient items. While much remains to be learned, memory detection 2.0 seems to offer an interesting new platform to efficiently and validly conduct RT-based memory detection research. PMID:25874966
Laban, Natasha M; Kobayashi, Tamaki; Hamapumbu, Harry; Sullivan, David; Mharakurwa, Sungano; Thuma, Philip E; Shiff, Clive J; Moss, William J
2015-01-28
Rapid diagnostic tests (RDTs) detecting histidine-rich protein 2 (PfHRP2) antigen are used to identify individuals with Plasmodium falciparum infection even in low transmission settings seeking to achieve elimination. However, these RDTs lack sensitivity to detect low-density infections, produce false negatives for P. falciparum strains lacking pfhrp2 gene and do not detect species other than P. falciparum. Results of a PfHRP2-based RDT and Plasmodium nested PCR were compared in a region of declining malaria transmission in southern Zambia using samples from community-based, cross-sectional surveys from 2008 to 2012. Participants were tested with a PfHRP2-based RDT and a finger prick blood sample was spotted onto filter paper for PCR analysis and used to prepare blood smears for microscopy. Species-specific, real-time, quantitative PCR (q-PCR) was performed on samples that tested positive either by microscopy, RDT or nested PCR. Of 3,292 total participants enrolled, 12 (0.4%) tested positive by microscopy and 42 (1.3%) by RDT. Of 3,213 (98%) samples tested by nested PCR, 57 (1.8%) were positive, resulting in 87 participants positive by at least one of the three tests. Of these, 61 tested positive for P. falciparum by q-PCR with copy numbers ≤ 2 x 10(3) copies/μL, 5 were positive for both P. falciparum and Plasmodium malariae and 2 were positive for P. malariae alone. RDT detected 32 (53%) of P. falciparum positives, failing to detect three of the dual infections with P. malariae. Among 2,975 participants enrolled during a low transmission period between 2009 and 2012, sensitivity of the PfHRP2-based RDT compared to nested PCR was only 17%, with specificity of >99%. The pfhrp gene was detected in 80% of P. falciparum positives; however, comparison of copy number between RDT negative and RDT positive samples suggested that RDT negatives resulted from low parasitaemia and not pfhrp2 gene deletion. Low-density P. falciparum infections not identified by currently used PfHRP2-based RDTs and the inability to detect non-falciparum malaria will hinder progress to further reduce malaria in low transmission settings of Zambia. More sensitive and specific diagnostic tests will likely be necessary to identify parasite reservoirs and achieve malaria elimination.
Hervert, C J; Alles, A S; Martin, N H; Boor, K J; Wiedmann, M
2016-09-01
It is estimated that 19% of the total food loss from retail, food service, and households comes from dairy products. A portion of this loss may be attributed to premature spoilage of products due to lapses in sanitation and postpasteurization contamination at the processing level. Bacterial groups including coliforms, Enterobacteriaceae (EB), and total gram-negative organisms represent indicators of poor sanitation or postpasteurization contamination in dairy products worldwide. Although Petrifilms (3M, St. Paul, MN) and traditional selective media are commonly used for the testing of these indicator organism groups throughout the US dairy industry, new rapid methods are also being developed. This project was designed to evaluate the ability of different methods to detect coliforms, EB, and other gram-negative organisms isolated from various dairy products and dairy processing environments. Using the Food Microbe Tracker database, a collection of 211 coliform, EB, and gram-negative bacterial isolates representing 25 genera associated with dairy products was assembled for this study. We tested the selected isolates in pure culture (at levels of approximately 15 to 300 cells/test) to evaluate the ability of 3M Coliform Petrifilm to detect coliforms, 3M Enterobacteriaceae Petrifilm, violet red bile glucose agar, and an alternative flow cytometry-based method (bioMérieux D-Count, Marcy-l'Étoile, France) to detect EB, and crystal violet tetrazolium agar to detect total gram-negative organisms. Of the 211 gram-negative isolates tested, 82% (174/211) had characteristic growth on crystal violet tetrazolium agar. Within this set of 211 gram-negative organisms, 175 isolates representing 19 EB genera were screened for detection using EB selective/differential testing methods. We observed positive results for 96% (168/175), 90% (158/175), and 86% (151/175) of EB isolates when tested on EB Petrifilm, violet red bile glucose agar, and D-Count, respectively; optimization of the cut-off thresholds for the D-Count may further improve its sensitivity and specificity, but will require additional data and may vary in food matrices. Additionally, 74% (129/175) of the EB isolates tested positive as coliforms. The data obtained from this study identify differences in detection between 5 microbial hygiene indicator tests and highlight the benefits of EB and total gram-negative testing methods. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
2010-02-01
vertical component records in a six-second window starting near the Lg detection time. Because our signal measurements are taken from the broadband...from the 2009 test. That is, comparable Love waves may have been generated by the 2006 test, but not at detectable levels. Secondary tectonic...kt., respectively. Relative yield estimates based on Lg observations from the two tests are generally consistent with the yield estimates obtained
Shu, Pei-Yun; Yang, Cheng-Fen; Kao, Jeng-Fong; Su, Chien-Ling; Chang, Shu-Fen; Lin, Chien-Chou; Yang, Wen-Chih; Shih, Hsiu; Yang, Shih-Yan; Wu, Ping-Fuai; Wu, Ho-Sheng; Huang, Jyh-Hsiung
2009-04-01
We used the dengue virus NS1 antigen (Ag) rapid test for on-site detection of imported dengue cases at airports. Among 22 positive cases of dengue identified from 850 patients with a fever suspected to have dengue, 17 were NS1 Ag test positive. These findings demonstrate the usefulness of the NS1 Ag rapid test in screening imported dengue cases at airports.
Shu, Pei-Yun; Yang, Cheng-Fen; Kao, Jeng-Fong; Su, Chien-Ling; Chang, Shu-Fen; Lin, Chien-Chou; Yang, Wen-Chih; Shih, Hsiu; Yang, Shih-Yan; Wu, Ping-Fuai; Wu, Ho-Sheng; Huang, Jyh-Hsiung
2009-01-01
We used the dengue virus NS1 antigen (Ag) rapid test for on-site detection of imported dengue cases at airports. Among 22 positive cases of dengue identified from 850 patients with a fever suspected to have dengue, 17 were NS1 Ag test positive. These findings demonstrate the usefulness of the NS1 Ag rapid test in screening imported dengue cases at airports. PMID:19193828
Coban, Ahmet Yilmaz; Uzun, Meltem
2013-01-01
Early detection of drug resistance in Mycobacterium tuberculosis isolates allows for earlier and more effective treatment of patients. The aim of this study was to investigate the performance of the malachite green decolourisation assay (MGDA) in detecting isoniazid (INH) and rifampicin (RIF) resistance in M. tuberculosis clinical isolates. Fifty M. tuberculosis isolates, including 19 multidrug-resistant, eight INH-resistant and 23 INH and RIF-susceptible samples, were tested. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and agreement of the assay for INH were 92.5%, 91.3%, 92.5%, 91.3% and 92%, respectively. Similarly, the sensitivity, specificity, PPV, NPV and agreement of the assay for RIF were 94.7%, 100%, 100%, 96.8% and 98%, respectively. There was a major discrepancy in the tests of two isolates, as they were sensitive to INH by the MGDA test, but resistant by the reference method. There was a minor discrepancy in the tests of two additional isolates, as they were sensitive to INH by the reference method, but resistant by the MGDA test. The drug susceptibility test results were obtained within eight-nine days. In conclusion, the MGDA test is a reliable and accurate method for the rapid detection of INH and RIF resistance compared with the reference method and the MGDA test additionally requires less time to obtain results. PMID:24402143
Phenotypic Detection of Metallo-β-Lactamase in Imipenem-Resistant Pseudomonas aeruginosa
Khosravi, Yalda; Loke, Mun Fai; Chua, Eng Guan; Tay, Sun Tee; Vadivelu, Jamuna
2012-01-01
Carbapenems are the primary choice of treatment for severe Pseudomonas aeruginosa infection. However, the emergence of carbapenem resistance due to the production of metallo-β-lactamases (MBLs) is of global concern. In this study, 90 imipenem- (IPM- or IP-) resistant P. aeruginosa (IRPA) isolates, including 32 previously tested positive and genotyped for MBL genes by PCR, were subjected to double-disk synergy test (DDST), combined disk test (CDT), and imipenem/imipenem-inhibitor (IP/IPI) E-test to evaluate their MBLs detection capability. All three methods were shown to have a sensitivity of 100%. However, DDST was the most specific of the three (96.6%), followed by IP/IPI E-test interpreted based on the single criteria of IP/IPI ≥8 as positive (62.1%), and CDT was the least specific (43.1%). Based on the data from this evaluation, we propose that only IRPA with IP MIC >16 μg/mL and IP/IPI ≥8 by IP/IPI E-test should be taken as positive for MBL activity. With the new dual interpretation criteria, the MBL IP/IPI E-test was shown to achieve 100% sensitivity as well as specificity for the IRPA in this study. Therefore, the IP/IPI E-test is a viable alternative phenotypic assay to detect MBL production in IRPA in our population in circumstances where PCR detection is not a feasible option. PMID:22792048
Laser-Ultrasonic Testing and its Applications to Nuclear Reactor Internals
NASA Astrophysics Data System (ADS)
Ochiai, M.; Miura, T.; Yamamoto, S.
2008-02-01
A new nondestructive testing technique for surface-breaking microcracks in nuclear reactor components based on laser-ultrasonics is developed. Surface acoustic wave generated by Q-switched Nd:YAG laser and detected by frequency-stabilized long pulse laser coupled with confocal Fabry-Perot interferometer is used to detect and size the cracks. A frequency-domain signal processing is developed to realize accurate sizing capability. The laser-ultrasonic testing allows the detection of surface-breaking microcrack having a depth of less than 0.1 mm, and the measurement of their depth with an accuracy of 0.2 mm when the depth exceeds 0.5 mm including stress corrosion cracking. The laser-ultrasonic testing system combined with laser peening system, which is another laser-based maintenance technology to improve surface stress, for inner surface of small diameter tube is developed. The generation laser in the laser-ultrasonic testing system can be identical to the laser source of the laser peening. As an example operation of the system, the system firstly works as the laser-ultrasonic testing mode and tests the inner surface of the tube. If no cracks are detected, the system then changes its work mode to the laser peening and improves surface stress to prevent crack initiation. The first nuclear industrial application of the laser-ultrasonic testing system combined with the laser peening was completed in Japanese nuclear power plant in December 2004.