Tatebe, Chiye; Ohtsuki, Takashi; Fujita, Tsuyoshi; Nishiyama, Koji; Itoh, Sumio; Sugimoto, Naoki; Kubota, Hiroki; Tada, Atsuko; Sato, Kyoko; Akiyama, Hiroshi
2017-12-15
The main subsidiary color of structure in Food Red No. 106 (R106) was identified to be a desethyl derivative (R106-SubA). High-performance liquid chromatography (HPLC) was performed for the quantitative determination of benzaldehyde-2,4-disulfonic acid, N,N-diethyl-m-aminophenol, leuco acid, pyrone acid, R106-SubA, etc. in R106. An ammonium acetate solution (20mM) and acetonitrile:water (7:3) were used to stabilize the retention time of the HPLC analytes. The linearity of the calibration curves was in the range of 0.05-10μg/mL, with good correlation coefficients (R 2 >0.9983). The recoveries of impurities at levels 0.1%, 0.5% and 1% ranged from 94.2% to 106.6% with relative standard deviations of 0.1%-1.0%. While surveying commercial R106, the amounts obtained by area% determination were similar to those obtained by the calibration-curve determination. The area% determination by HPLC for the determinations of impurities in R106 is a simple and reliable method and can be applied in routine analysis. Copyright © 2017 Elsevier Ltd. All rights reserved.
Vapor pressures of new fluorocarbons
NASA Astrophysics Data System (ADS)
Kubota, H.; Yamashita, T.; Tanaka, Y.; Makita, T.
1989-05-01
The vapor pressures of four fluorocarbons have been measured at the following temperature ranges: R123 (2,2-dichloro-l,l,l-trifluoroethane), 273 457 K; R123a (1,2-dichloro-1,1,2-trifluoroethane), 303 458 K; R134a (1,1,1,2-tetrafluoroethane), 253 373 K; and R132b (l,2-dichloro-l,l-difluoroethane), 273 398 K. Determinations of the vapor pressure were carried out by a constant-volume apparatus with an uncertainty of less than 1.0%. The vapor pressures of R123 and R123a are very similar to those of R11 over the whole experimental temperature range, but the vapor pressures of R134a and R132b differ somewhat from those of R12 and R113, respectively, as the temperature increases. The numerical vapor pressure data can be fitted by an empirical equation using the Chebyshev polynomial with a mean deviation of less than 0.3 %.
Rapid RHD Zygosity Determination Using Digital PCR.
Sillence, Kelly A; Halawani, Amr J; Tounsi, Wajnat A; Clarke, Kirsty A; Kiernan, Michele; Madgett, Tracey E; Avent, Neil D
2017-08-01
Paternal zygosity testing is used for determining homo- or hemizygosity of RHD in pregnancies that are at a risk of hemolytic disease of the fetus and newborn. At present, this is achieved by using real-time PCR or the Rhesus box PCR, which can be difficult to interpret and unreliable, particularly for black African populations. DNA samples extracted from 53 blood donors were analyzed using 2 multiplex reactions for RHD -specific targets against a reference ( AGO1 ) 2 to determine gene dosage by digital PCR. Results were compared with serological data, and the correct genotype for 2 discordant results was determined by long-range PCR (LR-PCR), next-generation sequencing, and conventional Sanger sequencing. The results showed clear and reliable determination of RHD zygosity using digital PCR and revealed that 4 samples did not match the serologically predicted genotype. Sanger sequencing and long-range PCR followed by next-generation sequencing revealed that the correct genotypes for samples 729M and 351D, which were serologically typed as R 1 R 2 (DCe/DcE), were R 2 r' (DcE/dCe) for 729M and R 1 r″ (DCe/dcE), R 0 r y (Dce/dCE), or R Z r (DCE/dce) for 351D, in concordance with the digital PCR data. Digital PCR provides a highly accurate method to rapidly define blood group zygosity and has clinical application in the analysis of Rh phenotyped or genotyped samples. The vast majority of current blood group genotyping platforms are not designed to define zygosity, and thus, this technique may be used to define paternal RH zygosity in pregnancies that are at a risk of hemolytic disease of the fetus and newborn and can distinguish between homo- and hemizygous RHD -positive individuals. © 2017 American Association for Clinical Chemistry.
Vapor pressures of new fluorocarbons
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kubota, H.; Yamashita, T.; Tanaka, Y.
1989-05-01
The vapor pressures of four fluorocarbons have been measured at the following temperature ranges: R123 (2,2-dichloro-1,1,1-trifluoroethane), 273-457 K; R123a (1,2-dichloro-1,1,2-trifluoroethane), 303-458 K; R134a (1,1,1,2-tetrafluoroethane), 253-373 K; and R132b (1,2-dichloro-1,1-difluoroethane), 273-398 K. Determinations of the vapor pressure were carried out by a constant-volume apparatus with an uncertainty of less than 1.0%. The vapor pressures of R123 and R123a are very similar to those of R11 over the whole experimental temperature range, but the vapor pressures of R134a and R132b differ somewhat from those of R12 and R113, respectively, as the temperature increases. The numerical vapor pressure data can be fitted bymore » an empirical equation using the Chebyshev polynomial with a mean deviation of less than 0.3%.« less
Comparison of radiographic and anatomic femoral varus angle measurements in normal dogs.
Swiderski, Jennifer K; Radecki, Steven V; Park, Richard D; Palmer, Ross H
2008-01-01
To determine if the clinically practiced method of radiographic femoral varus angle (R-FVA) measurement is repeatable, reproducible, and accurate. Radiographic and anatomic study. ANIMALS/SAMPLE POPULATION: Normal Walker hound cadavers (n=5) and femora (n=10). Cadavers were held in dorsally-recumbent and torso-elevated positions as 3 craniocaudal radiographs were made of each femur, by each of 2 different technicians. Femora were then harvested for direct measurement of anatomic femoral varus angle (A-FVA). R-FVA was measured on each radiograph by each of 3 examiners on 3 separate occasions. Intra-observer (repeatability) and inter-observer (reproducibility) variance in R-FVA measurement and the strength of relationship between R-FVA and A-FVA (accuracy) were determined. Mean (+/-SD) A-FVA was 5.2+/-2.1 degrees (range, 2.4-8.2 degrees). Mean (+/-SD) R-FVA was 5.8+/-1.0 degrees (range, 2.7-9.6 degrees). Intra-observer variance (range: 11-16%) and inter-observer variance (16%) were acceptable. The strength of relationship between measured R-FVA and A-FVA (maximum adjusted R(2)<0) was unacceptably low regardless of observer, patient position, or radiographic technician. R-FVA measurement was repeatable and reproducible, but not statistically accurate in predicting A-FVA in these 5 normal Walker hounds. The detected inaccuracy may be real or the result of a selection bias for normal dogs obscuring the true relationship. R-FVA may not be an accurate method of femoral varus measurement in dogs with A-FVA<10 degrees. Using Slocum's criteria for distal femoral osteotomy (R-FVA>10 degrees), the procedure would not have been erroneously performed in any of the normal dogs of this study.
Parlesak, A; Bode, J C; Bode, C
1994-11-01
Polyethylene glycol has been in use for a number of years for the assessment of gut permeability. The methods so far employed are usually limited to polyethylene glycols in the low relative molecular mass range (up to M(r) 1300). We developed a method for the simultaneous determination of gut permeability to M(r) 400, M(r) 1500, M(r) 4000 and M(r) 10,000 polyethylene glycol, by applying a single oral dose of an appropriate mixture of these polyethylene glycols. After extraction from 24 h-urine, M(r) 1500, M(r) 4000 and M(r) 10,000 polyethylene glycol were quantified by size exclusion chromatography, while M(r) 400 polyethylene glycol was determined by reversed phase chromatography. The detection limit of polyethylene glycol in the relative molecular mass range between M(r) 1500 and M(r) 10,000 was found to be 0.2 mg/l urine, and the detection limit of M(r) 400 polyethylene glycol 5 mg/l urine. Recovery of the polyethylene glycols (N = 6) were 86.6% (CV: 4.8%) for M(r) 400, 94.1% (CV: 7.2%) for M(r) 1500, 97.1% (CV: 5.5%) for M(r) 4000 and 97.4% (CV: 5.6%) for M(r) 10,000. No significant difference was found between the excretion rates in 24 h-urine of M(r) 400 and M(r) 1500 polyethylene glycols in patients with Crohn's disease (M(r) 400: 34.4 +/- 5.5%; M(r) 1500: 5.22 +/- 2.27%; mean +/- SEM, N = 10) and healthy controls (M(r) 400: 33.6 +/- 3.2%, M(r) 1500: 1.09 +/- 0.26%; N = 21). The excretion rate of M(r) 4000 polyethylene glycol was markedly higher in patients with Crohn's disease (0.462 +/- 0.177%) than in healthy controls (0.049 +/- 0.012%, p < 0.05).(ABSTRACT TRUNCATED AT 250 WORDS)
Sławik, Tomasz; Kowalski, Cezary
2002-04-05
The lipophilicity (R(Mo)) and specific hydrophobic surface area of seven 1,2-benzisothiazol-3(2H)-ones have been determined by reversed-phase TLC and the effect of different mobile-phase modifiers (acetone, acetonitrile, methanol) on the retention has been studied. The linear correlations between the volume fraction of the organic solvent and the R(M) values over a limited range were established for each solute with high values of correlation coefficients (>0.99). The influence of solvent pH on R(M) values was investigated.
Anderson, Stephan W; Soto, Jorge A; Milch, Holly N; Ozonoff, Al; O'Brien, Michael; Hamilton, James A; Jara, Hernan J
2011-04-01
To evaluate the apparent diffusion coefficient (ADC) values of liver in a murine model of non-alcoholic steatohepatitis using 11.7 Tesla (T) MRI. This animal study was IACUC approved. Seventeen male C57BL/6 mice were divided into control (n = 3) and experimental groups (n = 14) fed a methionine-deficient choline-deficient (MCD) diet to induce steatohepatitis. Livers underwent ex vivo diffusion-weighted MR imaging and ADC maps were calculated. A pathologist determined subjective scores of steatosis, classified from 0 to 3. Digital image analysis was used to determine percentage areas of steatosis. Graphs comparing ADC to subjective and digital image analysis (DIA) determinations of steatosis were plotted. Subjective assessments of steatosis ranged up to values of 3 and DIA determined areas of steatosis to range up to approximately 16%. ADC values approximated 800 × 10(-6) mm(2) /s (range, 749-811 × 10(-6) mm(2) /s, mean 786 × 10(-6) mm(2) /s) in controls and 500 × 10(-6) mm(2) /s (range, 478-733 × 10(-6) mm(2) /s, mean 625 × 10(-6) mm(2) /s) in experimental mice. Moderate correlation between ADC and subjective scores of steatosis (R = -0.56) was observed. Strong correlation between ADC values and percentage areas of steatosis was between ADC values and percentage areas of steatosis was observed greater (R = -0.81) and very strong correlation was observed with the exclusion of a single outlying data point (R = -0.91). Based on the comparison of ADC values and steatosis determinations by DIA, increasing degrees of steatosis are seen to result in decreased hepatic ADC values. Copyright © 2011 Wiley-Liss, Inc.
Effect of short-range correlations on the single proton 3s1/2 wave function in 206Pb
NASA Astrophysics Data System (ADS)
Shlomo, S.; Talmi, I.; Anders, M. R.; Bonasera, G.
2018-02-01
We consider the experimental data for difference, Δρc (r), between the charge density distributions of the isotones 206Pb - 205Tl, deduced by analysis of elastic electron scattering measurements and corresponds to the shell model 3s1/2 proton orbit. We investigate the effects of two-body short-range correlations. This is done by: (a) Determining the corresponding single particle potential (mean-field), employing a novel method, directly from the single particle proton density and its first and second derivatives. We also carried out least-square fits to parametrized single particle potentials; (b) Determining the short-range correlations effect by employing the Jastrow correlated many-body wave function to derive a correlation factor for the single particle density distribution. The 3s 1/2 wave functions of the determined potentials reproduce fairly well the experimental data within the quoted errors. The calculated charge density difference, Δρc (r), obtained with the inclusion of the short-range correlation effect does not reproduce the experimental data.
NASA Astrophysics Data System (ADS)
Al-Hawat, Sharif
2013-02-01
Infrared (IR) absorption in the spectral range of (1071.88-1084.62 cm-1) vs. pressure in chlorodifluoromethane (CFC-22, F-22, and CHClF2) was studied using a tunable continuous wave (CW) CO2 laser radiation on 9R branch lines with a maximum output power of about 2.12 W, provided with an absorber cell located outside the laser cavity. The absorption coefficients were determined vs. the gas pressure between 0.2 mbar and 170 mbar at lines from 9R branch for CFC-22. The frequency shifts of the absorption lines of CFC-22 in relative to the central frequencies of laser lines were calculated vs. the pressure on the basis of these absorption coefficients. The chosen lines were selected according to IR spectrum of the studied gas given by HITRAN cross section database. So the absorption was achieved for CFC-22 at the spectral lines of 9R branch situated from 9R (10) to 9R (30) emitted by a tunable CW CO2 laser. The absorption cross sections of CFC-22 determined in this work were compared with the relevant data given by HITRAN cross section database and a reasonable agreement was observed.
Investigation of vacuum pumping on the dose response of the MAGAS normoxic polymer gel dosimeter.
Venning, A J; Mather, M L; Baldock, C
2005-06-01
The effect of vacuum pumping on the dose response of the MAGAS polymer gel dosimeter has been investigated. A delay of several days post-manufacture before irradiation was previously necessary due to the slow oxygen scavenging of ascorbic acid. The MAGAS polymer gel dosimeter was vacuum pumped before gelation to remove dissolved oxygen. The MAGAS polymer gel dosimeter was poured into glass screw-top vials, which were irradiated at various times, post-manufacture to a range of doses. Magnetic resonance imaging techniques were used to determine the R2-dose response and R2-dose sensitivity of the MAGAS polymer gel. The results were compared with a control batch of MAGAS polymer gel that was not vacuum pumped. It was shown that vacuum pumping on the MAGAS polymer gel solution immediately prior to sealing in glass screw-top vials initially increases the R2-dose response and R2-dose sensitivity of the dosimeter. An increase in the R2-dose response and R2-dose sensitivity was observed with increasing time between manufacture and irradiation. Over the range of post-manufacture irradiation times investigated, the greatest R2-dose response and R2-dose sensitivity occurred at 96 hours.
NASA Astrophysics Data System (ADS)
Cartier, Camille; Hammouda, Tahar; Doucelance, Régis; Boyet, Maud; Devidal, Jean-Luc; Moine, Bertrand
2014-04-01
In order to investigate the influence of very reducing conditions, we report enstatite-melt trace element partition coefficients (D) obtained on enstatite chondrite material at 5 GPa and under oxygen fugacities (fO2) ranging between 0.8 and 8.2 log units below the iron-wustite (IW) buffer. Experiments were conducted in a multianvil apparatus between 1580 and 1850 °C, using doped (Sc, V, REE, HFSE, U, Th) starting materials. We used a two-site lattice strain model and a Monte-Carlo-type approach to model experimentally determined partition coefficient data. The model can fit our partitioning data, i.e. trace elements repartition in enstatite, which provides evidence for the attainment of equilibrium in our experiments. The precision on the lattice strain model parameters obtained from modelling does not enable determination of the influence of intensive parameters on crystal chemical partitioning, within our range of conditions (fO2, P, T, composition). We document the effect of variable oxygen fugacity on the partitioning of multivalent elements. Cr and V, which are trivalent in the pyroxene at around IW - 1 are reduced to 2+ state with increasingly reducing conditions, thus affecting their partition coefficients. In our range of redox conditions Ti is always present as a mixture between 4+ and 3+ states. However the Ti3+-Ti4+ ratio increases strongly with increasingly reducing conditions. Moreover in highly reducing conditions, Nb and Ta, that usually are pentavalent in magmatic systems, appear to be reduced to lower valence species, which may be Nb2+ and Ta3+. We propose a new proxy for fO2 based on D(Cr)/D(V). Our new data extend the redox range covered by previous studies and allows this proxy to be used in the whole range of redox conditions of the solar system objects. We selected trace-element literature data of six chondrules on the criterion of their equilibrium. Applying the proxy to opx-matrix systems, we estimated that three type I chondrules have equilibrated at IW - 7 ± 1, one type I chondrule at IW - 4 ± 1, and two type II chondrules at IW + 3 ± 1. This first accurate estimation of enstatite-melt fO2 for type I chondrules is very close to CAI values. Find the best-fit for trivalent elements. We set the r0M1 (3+) range to 0.55-0.75 Å, based on visual observations of the datapoints. For the other variables we have set boundary values beyond which the solutions would be unacceptable. For example, r0M2 (3+) has to be larger than r0M1 (3+). Finally we restricted the D0 range as follow: 0.2
Houser, J.N.; Mulholland, P.J.; Maloney, K.O.
2006-01-01
Because catchment characteristics determine sediment and nutrient inputs to streams, upland disturbance can affect stream chemistry. Catchments at the Fort Benning Military Installation (near Columbus, Georgia) experience a range of upland disturbance intensities due to spatial variability in the intensity of military training. We used this disturbance gradient to investigate the effects of upland soil and vegetation disturbance on stream chemistry. During baseflow, mean total suspended sediment (TSS) concentration and mean inorganic suspended sediment (ISS) concentration increased with catchment disturbance intensity (TSS: R2 = 0.7, p = 0.005, range = 4.0-10.1 mg L-1; ISS: R2 = 0.71, p = 0.004, range = 2.04-7.3 mg L-1); dissolved organic carbon (DOC) concentration (R2 = 0.79, p = 0.001, range = 1.5-4.1 mg L-1) and soluble reactive phosphorus (SRP) concentration (R2 = 0.75, p = 0.008, range = 1.9-6.2 ??g L-1) decreased with increasing disturbance intensity; and ammonia (NH 4+), nitrate (NO3-), and dissolved inorganic nitrogen (DIN) concentrations were unrelated to disturbance intensity. The increase in TSS and ISS during storms was positively correlated with disturbance (R2 = 0.78 and 0.78, p = 0.01 and 0.01, respectively); mean maximum change in SRP during storms increased with disturbance (r = 0.7, p = 0.04); and mean maximum change in NO3- during storms was marginally correlated with disturbance (r = 0.58, p = 0.06). Soil characteristics were significant predictors of baseflow DOC, SRP, and Ca 2+, but were not correlated with suspended sediment fractions, any nitrogen species, or pH. Despite the largely intact riparian zones of these headwater streams, upland soil and vegetation disturbances had clear effects on stream chemistry during baseflow and stormflow conditions. ?? ASA, CSSA, SSSA.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Houser, Jeffrey N
2006-01-01
Because catchment characteristics determine sediment and nutrient inputs to streams, upland disturbance can affect stream chemistry. Catchments at the Fort Benning Military Installation (near Columbus, Georgia) experience a range of upland disturbance intensities due to spatial variability in the intensity of military training. We used this disturbance gradient to investigate the effects of upland soil and vegetation disturbance on stream chemistry. During baseflow, mean total suspended sediment (TSS) concentration and mean inorganic suspended sediment (ISS) concentration increased with catchment disturbance intensity (TSS: R 2 = 0.7, p = 0.005, range = 4.0-10.1 mg L-1; ISS: R 2 = 0.71, pmore » = 0.004, range = 2.04-7.3 mg L-1); dissolved organic carbon (DOC) concentration (R 2 = 0.79, p = 0.001, range = 1.5-4.1 mg L-1) and soluble reactive phosphorus (SRP) concentration (R 2 = 0.75, p = 0.008, range = 1.9-6.2 {micro}g L-1) decreased with increasing disturbance intensity; and ammonia (NH4 +), nitrate (NO3 -), and dissolved inorganic nitrogen (DIN) concentrations were unrelated to disturbance intensity. The increase in TSS and ISS during storms was positively correlated with disturbance (R 2 = 0.78 and 0.78, p = 0.01 and 0.01, respectively); mean maximum change in SRP during storms increased with disturbance (r = 0.7, p = 0.04); and mean maximum change in NO3 - during storms was marginally correlated with disturbance (r = 0.58, p = 0.06). Soil characteristics were significant predictors of baseflow DOC, SRP, and Ca2+, but were not correlated with suspended sediment fractions, any nitrogen species, or pH. Despite the largely intact riparian zones of these headwater streams, upland soil and vegetation disturbances had clear effects on stream chemistry during baseflow and stormflow conditions.« less
Magnetic properties and magnetocaloric effect of HoCo3B2 compound
NASA Astrophysics Data System (ADS)
Zheng, X. Q.; Xu, J. W.; Zhang, H.; Zhang, J. Y.; Wang, S. G.; Zhang, Y.; Xu, Z. Y.; Wang, L. C.; Shen, B. G.
2018-05-01
A sample of HoCo3B2 compound was synthesized, and the magnetic and MCE properties were investigated. Compound shows a change corresponding to R-R (R = rare earth) sublattice magnetic order transition and the transition temperature is determined to be 11.8 K (TC). The characteristic of Arrott plots with positive slope around TC was observed, indicating a second-order phase transition. Based on isothermal magnetization data, together with Maxwell's relationship, the magnetic entropy change (-ΔSM) was calculated. The maximum -ΔSM reaches 7.8, 12.7 and 14.4 J/kg K for field range of 0-2 T, 0-5 T and 0-7 T, respectively. Accordingly, the value of RC (refrigerant capacity) is 99, 289 and 432 J/kg for above field ranges. The large MCE of HoCo3B2 compound indicates its potential application for magnetic refrigeration in low temperature range.
Saavedra-Hernández, Manuel; Castro-Sánchez, Adelaida M; Cuesta-Vargas, Antonio I; Cleland, Joshua A; Fernández-de-las-Peñas, César; Arroyo-Morales, Manuel
2012-12-01
The influence of physical and psychosocial variables on self-rated disability in patients with chronic mechanical neck pain has not been fully determined. This study examined the relationship of pain, physical impairment, and pain-related fear to disability in individuals with chronic mechanical neck pain. A cross-sectional study was conducted. Ninety-seven (n = 97) subjects (28 men, 69 women; mean age, 39.3 yrs) with chronic mechanical neck pain were prospectively recruited. Demographic information, duration of pain symptoms, pain intensity, pain-related fear, and cervical range of motion were collected on all subjects. Self-reported disability was measured with the Neck Disability Index. Correlation and regression analyses were performed to determine the association among the variables and to determine the proportions of explained variance in disability. Significant positive correlations existed between disability and previous history of neck pain (r = 0.45; P < 0.001), disability and pain intensity (r = 0.32, P = 0.01), and disability and kinesiophobia (r = 0.23, P = 0.02). In addition, a significant negative correlation existed between disability and cervical extension range of motion (r = -0.18, P = 0.04). Stepwise regression analyses revealed that previous neck pain episodes, intensity of neck pain, kinesiophobia, and cervical extension range of motion were significant predictors of disability (r = 0.400; r adjusted = 0.372; F = 14.64; P < 0.001). This study found that previous episodes of neck pain, pain intensity, pain-related fear, and cervical extension range of motion explained 37.2% of the variability of self-report disability. Future longitudinal studies will help to determine the clinical implications of these findings.
Araujo Júnior, Edward; Martins, Wellington P; Nardozza, Luciano Marcondes Machado; Pires, Claudio Rodrigues; Filho, Sebastião Marques Zanforlin
2015-02-01
To determine a reference range of fetal transverse cerebellar diameter in Brazilian population. This was a retrospective cross-sectional study with 3772 normal singleton pregnancies between 18 and 24 weeks of pregnancy. The transverse cerebellar diameter was measured on the axial plane of the fetal head at the level of the lateral ventricles, including the thalamus, cavum septum pellucidum, and third ventricle. To assess the correlation between transverse cerebellar diameter and gestational age, polynomial equations were calculated, with adjustments by the determination coefficient (R2). The mean of fetal transverse cerebellar diameter ranged from 18.49 ± 1.24 mm at 18 weeks to 25.86 ± 1.66 mm at 24 weeks of pregnancy. We observed a good correlation between transverse cerebellar diameter and gestational age, which was best represented by a linear equation: transverse cerebellar diameter: -6.21 + 1.307*gestational age (R2 = 0.707). We determined a reference range of fetal transverse cerebellar diameter for the second trimester of pregnancy in Brazilian population. © The Author(s) 2014.
NASA Technical Reports Server (NTRS)
Feibelman, Walter A.; Aller, Lawrence H.
1987-01-01
Suitable IUE archival material on planetary nebulae has been examined to determine the log R /F(lambda 1909 C III)/F(lambda 1892 Si III)/ as a discriminant for distinguishing planetary nebulae from symbiotic stars and related objects. The mean value of log R for 73 galactic planetaries is 1.4, while that of extragalactic planetaries appears to be slightly lower, and that for symbiotics is 0.3. The lower value of log R for symbiotics is easily understood as a consequence of their higher densities. A plot of log R versus N-epsilon indicates that 80 percent of the planetaries fall into the range of log R between 1.2 and 1.8, but some of the 'peculiar' and bipolar nebulae fall below log R = 1.2. The corresponding N(C++)/N(Si++) ionic ratio varies over a large range.
Lee, Kyung Ran; Nguyen, NgocVan Thi; Lee, Yong Jae; Choi, Seungho; Kang, Jong Seong; Mar, Woongchon; Kim, Kyeong Ho
2015-01-01
Capillary zone electrophoresis was successfully applied to the enantiomeric purity determination of valsartan using acetyl-β-cyclodextrin (A-β-CD) as a chiral selector. Separations were carried out in a 50 µm, 64/56 cm fused-silica capillary. The optimized conditions included 25 mM phosphate buffer, pH 8.0, containing 10 mM A-β-CD as background electrolyte, an applied voltage of +30 kV and a temperature of 30 °C. Ibuprofen was used as an internal standard. The assay was validated for the R-enantiomer of valsartan in the range of 0.05-3.0%. The limit of detection was 0.01%, the limit of quantitation was 0.05%, relative to a concentration of valsartan of 1 mg/ml. Intra-day precision varied between 2.57 and 5.60%. Relative standard deviations of inter-day precision ranged between 4.46 and 6.76% for peak area ratio. The percentage recovery of the R-enantiomer of valsartan ranged between 97.0 and 99.6% in valsartan product. The assay was applied to the determination of the chiral purity of valsartan tablets and R-enantiomer of valsartan was found as an impurity.
Dynamics of Debris Motion and the Collision Hazard to Spacecraft Resulting from an Orbital Breakup
1988-01-01
Time, Clohessy - Wiltshire and Torus Approximation ....................................... 44 21. J2 Parameters, C1 , C2 , C3, versus Av; 200-nmi...revolving about the same gravitational attracting mass is the Clohessy - Wiltshire equations. In matrix form, the analytical solution is 38 r 42 x I 6(wt...can determine the range of validity of the Clohessy - Wiltshire equations. 3.3 RESULTS The range of validity can be determined by comparing the effects
Taylor, Michael J; Keenan, George A; Reid, Kirsty B; Fernández, Diana Uría
2008-09-01
The utility of ultra-performance liquid chromatography/orthogonal-acceleration time-of flight mass spectrometry (UPLC/TOFMS) for the rapid qualitative and quantitative analysis of 100 pesticides targeted in strawberry was assessed by comparing results with those obtained using a validated in-house UPLC tandem mass spectrometry (MS/MS) multi-residue method. Crude extracts from retail strawberry samples received as part of the 2007 annual UK pesticide residues in food surveillance programme were screened for the presence of pesticide residues using UPLC/TOFMS. Accurate mass measurement of positive and negative ions allowed their extraction following 'full mass range data acquisition' with negligible interference from background or co-eluting species observed during UPLC gradient separation (in a cycle time of just 6.5 min per run). Extracted ion data was used to construct calibration curves and to detect and identify any incurred residues (i.e. pesticides incorporated in or on the test material following application during cultivation, harvest and storage). Calibration using matrix-matched standards was performed over a narrow concentration range of 0.005-0.04 mg kg(-1) with determination coefficients (r2) > or =0.99 for all analytes with the exception of malathion/fenarimol/fludioxanil (r2 = 0.98), quassia/pymetrazine (r2 = 0.97) and fenthion sulfone (r2 = 0.95). Residues found in selected samples ranged from 0.025-0.28 mg kg(-1) and were in excellent agreement with results obtained using UPLC/MS/MS. Mass measurement accuracies of < or =5 ppm were achieved consistently throughout the separation, mass range and concentration range of interest thus providing the opportunity to obtain discrete elemental compositions of target ions.
Chen, Lin; Xiao, Qingqing; Zhang, Xian; Yang, Jin
2016-03-20
2-[1-Hexyloxyethyl]-2-devinyl pyropheophorbide-a (HPPH) is a second-generation photosensitizer that has been applied in clinical studies of photodynamic therapy for a variety of malignant lesions. Based on the differences in selectivity and labour intensity, three novel methods - fluorescence detection coupled with high performance liquid chromatography (LC-FLD), LC-tandem mass spectrometry (LC-MS/MS) and fluorescence-based microplate reader methods - were developed for the determination of HPPH in human serum, which allowed comparison of fluorescence and MS platform for HPPH quantification. All three methods have been validated and successfully applied to support the clinical pharmacokinetic study of HPPH. The concentrations measured by LC-FLD matched those by LC-MS/MS with a correlation coefficient (r=0.994) and coefficient of determination (r(2)=0.989). Data consistency was also found between the measurements of microplate reader and LC-MS/MS with a correlation coefficient (r=0.999) and coefficient of determination (r(2)=0.998), indicating that fluorescence assay, the low cost alternative with a relatively poorer selectivity, is clearly suitable for the quantification of HPPH. Calibration curves in the methods of LC-FLD and microplate reader were linear (r˃0.998) over the concentration range from 50 to 5000 ng/mL, and linearity was obtained over the concentration range from 5 to 1000 ng/mL in the LC-MS/MS method. Compared with the other two methods, the fluorescence-based microplate reader method with proven high selectivity should be strongly recommended because of obvious advantages such as the lowest labour intensity, the lowest instrument cost, a better sensitivity than LC-FLD and the very rapid determination of large number of samples (24 samples/40 s). Copyright © 2015 Elsevier B.V. All rights reserved.
Horn, Julia; Kleber, Martina; Hieke, Stefanie; Schmitt-Gräff, Annette; Wäsch, Ralph; Engelhardt, Monika
2012-10-01
We analyzed the safety and efficacy of rituximab plus bendamustine (R-B) in elderly and frail patients with aggressive B-non-Hodgkin lymphoma (a-B-NHL). Few reports have as yet reported on R-B in a-B-NHL, albeit its value for indolent lymphoma vs. R-CHOP has impressively been shown. We assessed 20 consecutive patients with a-B-NHL receiving R-B as first-line or relapse treatment after (R)-CHOP in our department. Besides patient- and lymphoma-specific characteristics, comorbidity indices were determined. The median patient age was 72 years (51-86), the median Karnofsky performance status was 55 % (40-90 %), and according to the international prognostic index, 15 had high-intermediate or high-risk disease. The comorbidity indices revealed a median Kaplan-Feinstein index of 3 (range 1-3), Charlson comorbidity index of 4 (range 0-9), hematopoietic cell transplantation-specific comorbidity index of 3 (range 0-11), and Freiburg comorbidity index of 2 (range 0-2). Moreover, eight patients had echocardiographic and laboratory signs of cardiac insufficiency, all leading to R-B rather than R-CHOP treatment. The overall response rate was 55 %, with complete response and partial response rates of 20 and 35 %, respectively. In our frail and elderly patient cohort, R-B therapy was well-tolerated. Median progression free survival and overall survival were 8.3 months (95 % confidence interval [CI], 2.8--not reached [n.r.]) and 19.4 months (95 % CI, 4.6--n.r.), respectively. We conclude that R-B is a feasible and safe therapy option in a-B-NHL patients not qualifying for R-CHOP but needs to be further assessed in larger subsequent trials, these currently being under way.
Parker, Gene W.; Armstrong, David S.; Richards, Todd A.
2004-01-01
Four methods used to determine streamflow requirements for habitat protection at nine critical riffle reaches in the Assabet River and Charles River Basins were compared. The methods include three standard setting techniques?R2Cross, Wetted Perimeter, and Tennant?and a diagnostic method, the Range of Variability Approach. One study reach is on the main stem of the Assabet River, four reaches are on tributaries to the Assabet River (Cold Harbor Brook, Danforth Brook, Fort Meadow Brook, and Elizabeth Brook), three are on the main stem of the Charles River, and one is on a tributary to the Charles River (Mine Brook). The strength of the R2Cross and Wetted-Perimeter methods is that they may be applied at ungaged locations whereas the Tennant method and the Range of Variability Approach require a period of streamflow record for analysis. Fish community assessments conducted at or near riffle sites in flowing reaches of the Assabet River and Charles River Basins were used to indicate ecological conditions. The fish communities in the main stem and tributary reaches of both the Assabet and Charles River Basins indicated degraded aquatic ecosystems. However, the degree of degradation differs between the two basins. The extreme predominance of tolerant, generalist species in the Charles River fish community demon-strates the cumulative impacts of flow, habitat, and water-chemistry degradation, combined with the effects of nearby impoundments and changing land use. The range of discharges for nine ungaged riffle reaches defined by the median R2Cross 3-of-3 criteria, R2Cross 2-of-3 criteria, and Wetted-Perimeter streamflow requirements, was 0.86 cubic foot per second per square mile, 0.18 cubic foot per second per square mile, and 0.23 cubic foot per second per square mile, respectively. Application of R2Cross and Wetted-Perimeter methods to sites with altered streamflows or at sites that are riffles only at low to moderate flows can result in a greater variability of streamflow requirements than would result if the methods were applied to riffles on natural channels with unaltered streamflows. The R2Cross 2-of-3 criteria and the Wetted-Perimeter streamflow requirements for the Assabet and Charles River sites show narrower interquartile ranges and lower median streamflow requirements than for 10 index streamflow-gaging stations in southern New England. This is especially evident for the R2Cross 2-of-3 criteria and Wetted-Perimeter results that were close to half of the flow requirements determined at the 10 southern New England stations. The R2Cross and Wetted-Perimeter methods were also compared to the Range of Variability Approach analysis and the Tennant Method. The median R2Cross 3-of-3 criteria streamflow requirement for the nine riffles is close to the 75th percentile of the monthly mean flows during the summer low-flow period from six streamflow-gaging stations near the Assabet and Charles River Basins having mostly unaltered flow. This streamflow requirement is close to the median Tennant 40-percent-flow requirement for good habitat condi-tion for the same six nearby stations. The R2Cross 2-of-3 criteria and Wetted-Perimeter results were less than the 25th-percentile of monthly mean flows during the summer months for the six stations. These streamflow requirements are in the poor habitat range as indicated by a Tennant analysis of the same six stations. These comparisons indicate that the R2Cross and Wetted-Perimeter methods underestimate streamflow requirements when applied to sites in smaller drainage areas and channels that are runs at higher flows.
Properties of Fr-like Th^3+ from microwave spectroscopy of high-L Rydberg states of Th^2+
NASA Astrophysics Data System (ADS)
Keele, Julie; Smith, Chris; Woods, Shannon; Lundeen, Stephen; Fehrenbach, Charles
2012-06-01
Spectroscopy of high-L n= 28 Rydberg levels of Th^2+ was recently reported using the optical RESIS method [1]. Because the ground state of Fr-like Th^3+ is a ^2F5/2 level, each (n,L) Rydberg level of Th^2+ is split into six eigenstates whose relative positions are determined by long-range e-Th^3+ interactions. Measurements of those positions can be used to determine the Th^3+ properties that control those interactions, such as polarizabilities and permanent moments. We report a much improved study of n=28 levels with 9 <= L <= 12, obtained with the microwave/RESIS method. The higher precision measurements allow improved determinations of a wider range of Th^3+ properties and a better test of theoretical calculations [2].[4pt] [1] Julie A. Keele, M.E. Hanni, Shannon L. Woods, S.R. Lundeen, and C.W. Fehrenbach, Phys. Rev. A 83, 062501 (2011)[0pt] [2] U.I. Safronova, W.R. Johnson, and M.S. Safronova, Phys. Rev. A 74, 042511 (2006)
Vindhyal, Mohinder; Vindhyal, Shravani R; Haneke, Travis; Ndunda, Paul M; Eid, Freidy; Kallail, K James
2017-12-11
Introduction Atrial fibrillation (AF), the most common cardiac arrhythmia, affects approximately 2.3 million patients in the United States, costing around $26 billion. Atrial fibrillation is associated with a two- to seven-fold increased risk of stroke, one of the most serious complications. Chronic kidney disease affects approximately 13% of the US population and has been associated with higher rates of AF than the general population. In patients with chronic kidney disease (CKD), the risk of stroke increases as the glomerular filtration rate (GFR) decreases, especially in CKD stages three and four. Several risks stratification scores such as CHADS2 (congestive heart failure, hypertension, age, diabetes mellitus, stroke), CHA2DS2VASc (congestive heart failure, hypertension, age, diabetes mellitus, stroke, vascular disease, age, sex), and R2CHADS2 (renal failure, congestive heart failure, age, diabetes, stroke) scores are used for stroke risk assessment in patients with non-valvular atrial fibrillation (NVAF). This study investigates the association between renal functions and risk stratification scoring systems in patients with non-valvular AF presenting with stroke. Methods Using the convenience sampling method, 171 subjects were selected from the eligible population (n = 386). A Pearson product-moment correlation coefficient was calculated to determine the association between the GFR and each of the CHA2DS2VASc and R2CHADS2 scores. In addition, a Pearson product-moment correlation coefficient was calculated to determine the association between the CHA2DS2VASc and R2CHADS2 scores. Results The selected population represented 44.3% of the eligible subjects. Of these, 88% were Caucasian, 60% were female, and the mean age was 78 years. The mean CHA2DS2VASc score was six (range 2-9). The mean eGFR was 69.77 (range 6-108). Both the mode and the median CHA2DS2VASc score was four (range 2-8). A weak, but significant, negative correlation was found between renal function (eGFR) and the CHA2DS2VASc score (r = -0.263; p = 0.0005). There was a stronger negative correlation between the eGFR and R2CHADS2score (r = -0.70; p < 0.00001). The CHA2DS2VASc and R2CHADS2scoring schemes were significantly and positively correlated (r = 0.627; p < 0.00001). Discussion In NVAF patients presenting with stroke, renal failure is associated with higher CHA2DS2VASc and R2CHADS2 scores. One must consider renal failure (end-stage or non-end stage renal failure) as an additional potential risk factor for stroke when recommending anticoagulation in non-valvular atrial fibrillation.
Composing chaotic music from the letter m
NASA Astrophysics Data System (ADS)
Sotiropoulos, Anastasios D.
Chaotic music is composed from a proposed iterative map depicting the letter m, relating the pitch, duration and loudness of successive steps. Each of the two curves of the letter m is based on the classical logistic map. Thus, the generating map is xn+1 = r xn(1/2 - xn) for xn between 0 and 1/2 defining the first curve, and xn+1 = r (xn - 1/2)(1 - xn) for xn between 1/2 and 1 representing the second curve. The parameter r which determines the height(s) of the letter m varies from 2 to 16, the latter value ensuring fully developed chaotic solutions for the whole letter m; r = 8 yielding full chaotic solutions only for its first curve. The m-model yields fixed points, bifurcation points and chaotic regions for each separate curve, as well as values of the parameter r greater than 8 which produce inter-fixed points, inter-bifurcation points and inter-chaotic regions from the interplay of the two curves. Based on this, music is composed from mapping the m- recurrence model solutions onto actual notes. The resulting musical score strongly depends on the sequence of notes chosen by the composer to define the musical range corresponding to the range of the chaotic mathematical solutions x from 0 to 1. Here, two musical ranges are used; one is the middle chromatic scale and the other is the seven- octaves range. At the composer's will and, for aesthetics, within the same composition, notes can be the outcome of different values of r and/or shifted in any octave. Compositions with endings of non-repeating note patterns result from values of r in the m-model that do not produce bifurcations. Scores of chaotic music composed from the m-model and the classical logistic model are presented.
Tachykinins Stimulate a Subset of Mouse Taste Cells
Grant, Jeff
2012-01-01
The tachykinins substance P (SP) and neurokinin A (NKA) are present in nociceptive sensory fibers expressing transient receptor potential cation channel, subfamily V, member 1 (TRPV1). These fibers are found extensively in and around the taste buds of several species. Tachykinins are released from nociceptive fibers by irritants such as capsaicin, the active compound found in chili peppers commonly associated with the sensation of spiciness. Using real-time Ca2+-imaging on isolated taste cells, it was observed that SP induces Ca2+ -responses in a subset of taste cells at concentrations in the low nanomolar range. These responses were reversibly inhibited by blocking the SP receptor NK-1R. NKA also induced Ca2+-responses in a subset of taste cells, but only at concentrations in the high nanomolar range. These responses were only partially inhibited by blocking the NKA receptor NK-2R, and were also inhibited by blocking NK-1R indicating that NKA is only active in taste cells at concentrations that activate both receptors. In addition, it was determined that tachykinin signaling in taste cells requires Ca2+-release from endoplasmic reticulum stores. RT-PCR analysis further confirmed that mouse taste buds express NK-1R and NK-2R. Using Ca2+-imaging and single cell RT-PCR, it was determined that the majority of tachykinin-responsive taste cells were Type I (Glial-like) and umami-responsive Type II (Receptor) cells. Importantly, stimulating NK-1R had an additive effect on Ca2+ responses evoked by umami stimuli in Type II (Receptor) cells. This data indicates that tachykinin release from nociceptive sensory fibers in and around taste buds may enhance umami and other taste modalities, providing a possible mechanism for the increased palatability of spicy foods. PMID:22363709
Relating the ac complex resistivity of the pinned vortex lattice to its shear modulus
NASA Astrophysics Data System (ADS)
Ong, N. P.; Wu, Hui
1997-07-01
We propose a way to determine the shear rigidity of the pinned vortex lattice in high-purity crystals from the dependence of its complex resistivity ρ⁁ on frequency (ω). The lattice is modeled as an elastic medium pinned by a sparse, random distribution of defects. We relate ρ⁁ to the velocity of the small subset of pinned vortices via the lattice propagator G(R,ω). Measuring ρ⁁ versus ω is equivalent to determining G(R,ω) versus R. The range of G(R,ω) depends sensitively on the shear and tilt moduli. We describe the evaluation of G(R,ω) in two-dimensional (2D) and 3D lattices. The 2D analysis provides a close fit to the frequency dependence of Reρ⁁ measured in an untwinned crystal of YBa2Cu3O7 at 89 K in a field of 0.5 and 1.0 T. We compare our results with earlier models.
Malakova, Jana; Pavek, Petr; Svecova, Lucie; Jokesova, Iveta; Zivny, Pavel; Palicka, Vladimir
2009-10-01
Warfarin is a well-known anticoagulant agent that occurs in two enantiomers, (R)-(+)-warfarin and (S)-(-)-warfarin. A new liquid chromatography method for the determination of both enantiomers was developed, validated and applied in in vitro studies with the aim of evaluating the accumulation of (R)-warfarin and (S)-warfarin in the hepatoma HepG2 cell line. OptiMEM cell cultivation medium samples and cellular lysates were purified using Waters Oasis MAX extraction cartridges. The chiral separation of warfarin and the internal standard p-chlorowarfarin enantiomers was performed on an Astec Chirobiotic V2 column at a flow rate of 1.2mL/min. The mobile phase was composed of 31% acetonitrile, 5% of methanol and 64% of ammonium acetate buffer (10mmol/L, pH 4.1). The enantiomers were quantified using a fluorescence detector (lambda(excit)=320nm, lambda(emiss)=415nm). The limit of detection was found to be 0.121micromol/L of (S)-warfarin and 0.109micromol/L of (R)-warfarin. The range of applicability and linearity was estimated from 0.25 to 100micromol/L. The precision ranged from 1.3% to 12.2% of the relative standard deviation, and the accuracy reached acceptable values from 95.5% to 108.4%. The new bioanalytical method confirmed the same accumulation of (R)-warfarin and (S)-warfarin in the hepatoma HepG2 cell line.
Younes, Magdy; Hanly, Patrick J
2016-04-01
Arousability from sleep is increasingly recognized as an important determinant of the clinical spectrum of sleep disordered breathing (SDB). Patients with SDB display a wide range of arousability. The reason for these differences is not known. We hypothesized that differences in the speed with which sleep deepens following arousals/awakenings (postarousal sleep dynamics) is a major determinant of these differences in arousability in patients with SDB. We analyzed 40 preexisting clinical polysomnography records from patients with a range of SDB severity (apnea-hypopnea index 5-135/h). Sleep depth was determined every 3 s using the odds ratio product (ORP) method, a continuous index of sleep depth (0 = deep sleep, 2.5 = full wakefulness) that correlates strongly (r = 0.98) with arousability (Younes M, Ostrowski M, Soiferman M, Younes H, Younes M, Raneri J, and Hanly P. Sleep 38: 641-654, 2015). Time course of ORP was determined from end of arousal until the next arousal. All arousals were analyzed (142 ± 65/polysomnogram). ORP increased from 0.58 ± 0.32 during sleep to 1.67 ± 0.35 during arousals. ORP immediately (first 9 s) following arousals/awakenings (ORP-9) ranged from 0.21(very deep sleep) to 1.71 (highly arousable state) in different patients. In patients with high ORP-9, sleep deepened slowly (over minutes) beyond 9 s but only if no arousals/awakenings recurred. ORP-9 correlated strongly with average non-rapid eye movement sleep depth (r = 0.87, P < 2E-13), the arousal/awakening index (r = 0.68, P < 5E-6), and with the apnea-hypopnea index (r = 0.60, P < 0.001). ORP-9 was consistent within each patient and did not change on continuous positive airway pressure despite marked improvement in sleep architecture. We conclude that postarousal sleep dynamics are highly variable among patients with sleep-disordered breathing and largely determine average sleep depth and continuity. Copyright © 2016 the American Physiological Society.
Nikolaou, Panagiota D; Papoutsis, Ioannis I; Maravelias, Constantinos P; Spiliopoulou, Chara A; Pistos, Constantinos M; Calokerinos, Antony C; Atta-Politou, Julia
2008-09-01
Methadone is used extensively for the maintenance of opioid-addicted pregnant women. Because methadone and the two major metabolites, 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine (EDDP) and 2-ethyl-5-methyl-3,3-diphenylpyrroline (EMDP), are excreted into breast milk, a sensitive and specific gas chromatographic-mass spectrometric method has been developed, optimized, and validated for their quantitative determination in human breast milk. The procedure combined protein precipitation with acetonitrile and solid-phase extraction, using Isolute Confirm HCX mixed-mode SPE columns, with minimal matrix effect. The optimum extraction conditions for all three analytes were evaluated using spiked human breast milk, and the recovery exceeded 93.0%. This assay uses methadone-d(9) as internal standard for the determination of methadone and EMDP, and EDDP-d(3) for the determination of EDDP. Calibration curves were linear within the range of 2.00-1000 microg/L for methadone (R(2) > 0.995) and 1.00-500 microg/L for EDDP (R(2) >0.997) and EMDP (R(2) > 0.991). Intra- and interday accuracy and precision were within the range of 0.8-5.7% and 1.3-5.2%, respectively, for all analytes. The stability study was assessed by fortifying human breast milk with methadone and its metabolites at two different concentrations and keeping the samples at different temperature conditions. The analytes were found to be stable in breast milk at room temperature for at least 4 h and at -20 degrees C for at least one month. The method was used for the determination of methadone and its major metabolites in human breast milk samples obtained from women in the postpartum period participating in a methadone maintenance program.
Measurement of the EMC effect in the deuteron
DOE Office of Scientific and Technical Information (OSTI.GOV)
Griffioen, Keith A.; Arrington, John R.; Christy, M. Eric
2015-07-21
We have determined the structure function ratiomore » $$R^d_{\\rm EMC}=F_2^d/(F_2^n+F_2^p)$$ from recently published $$F_2^n/F_2^d$$ data taken by the BONuS experiment using CLAS at Jefferson Lab. This ratio deviates from unity, with a slope $$dR_{\\rm EMC}^{d}/dx= -0.10\\pm 0.05$$ in the range of Bjorken $x$ from 0.35 to 0.7, for invariant mass $W>1.4$ GeV and $Q^2>1$ GeV$^2$. The observed EMC effect for these kinematics is consistent with conventional nuclear physics models that include off-shell corrections, as well as with empirical analyses that find the EMC effect proportional to the probability of short-range nucleon-nucleon correlations.« less
[Derivative synchronous fluorimetry for determination of synthetic food dyes in food].
Xie, Zhi-Hai; Wang, Ling-Yan; Liu, Yu; Cai, Qing; Wang, Hai-Li; Yan, Hong-Tao
2014-05-01
The first order derivative synchronous fluoremetry was proposed for simultaneous determination of sunset yellow and ponceau 4R The effect of different experimental conditions, such as different pH for character of fluorescence spectra and the choosing of the optimal wavelength difference were studied. It was showed that the zero-crossing points were at 313. 6 nm for ponceau 4R and at 302. 8 nm for sunset yellow in first order derivative synchronous fluorescence spectra. Therefore, 313. 6 and 302. 8 nm were selected for the determination of sunset yellow and ponceau 4R when delta lambda= 130 nm. This method could minimize interference without preseparation. The linear ranges of sunset yellow and ponceau 4R were from 0. 1 to 2. 0 mg L-1 and from 0. 1 to 4. 0 mg L-1 with correlation coefficient 0. 996 6 and 0. 999 2, the detection limits were 0. 041 and 0. 019 mg L-1 , RS-Ds were 4. 6% and 4. 8% (n=6), respectively. The recoveries varied from 91. 0% to 110%. The proposed method was successfully applied in simultaneous determination of sunset yellow and Ponceau 4R in food.
Lexchin, Joel
2018-01-01
Competing claims are made about the amount of money that pharmaceutical companies spend on research and development (R&D) versus promotion. This study investigates this question in the Canadian context. Two methods for determining industry-wide figures for spending on promotion were employed. First, total industry spending on detailing and journal advertising for 2013-2016 was abstracted from reports from QuintilesIMS. Second, the mean total promotion spending for the years 2002-2005 was used to estimate total spending for 2013-2016. Total industry spending on R&D came from the Patented Medicine Prices Review Board (PMPRB). R&D to promotion spending using each method of determining the amount spent on promotion was compared for 2013-2016 inclusive. Data on the 50 top promoted drugs, the amounts spent, the companies marketing these products and their overall sales were abstracted from the QuintilesIMS reports. Spending on R&D and promotion as a percent of sales was compared for these companies. Industry wide, the ratio of R&D to promotion spending went from 1.43 to 2.18 when promotion was defined as the amount spent on detailing and journal advertising for the 50 most promoted drugs. Calculating total promotion spending from the mean of the 2002-2005 figures the ratio was 0.88 to 1.32 for the 50 most promoted drugs. For individual companies marketing one or more of the 50 most promoted drugs, mean R&D spending ranged from 3.7% of sales to 4.1% compared to mean promotion spending that went from 1.7 to 1.9%. The ratio of spending on R&D to promotion varied from 2.11 to 2.32. Eight to 10 companies per year spent more on promotion than on R&D. Depending on the method used to determine promotion spending, industry-wide the ratio of R&D spending to promotion ranges from 1.45 to 2.18 (sales representatives and journal advertising only) or from 0.88 to 1.32 (total promotion spending estimated based 2003-2005 data.) For the individual companies promoting one or more of the 50 most promoted drugs, 2.11 to 2.32 times more is spent on R&D compared to promotion. However these results should be interpreted cautiously because of data limitations.
Mansilla, Alberto V; Bivins, Eugene E; Contreras, Francisco; Hernandez, Manuel A; Kohler, Nathan; Pepe, Julie W
2017-02-01
To develop a scoring system that stratifies complexity of percutaneous ablation of renal tumors. Analysis was performed of 36 consecutive patients (mean age, 64 y; range, 30-89 y) who underwent CT-guided microwave (MW) ablation of 45 renal tumors (mean tumor diameter, 2.4 cm; range, 1.2-4.0 cm). Technical success and effectiveness were determined based on intraprocedural and follow-up imaging studies. The RENAL score and the proposed percutaneous renal ablation complexity (P-RAC) score were calculated for each tumor. Technical success was 93.3% (n = 42). Biopsy of 38 of 45 renal tumors revealed 23 renal cell carcinomas. Median follow-up period was 9.7 months (range, 2.9-46.8 months). There were no tumor recurrences. One major complication, ureteropelvic junction stricture, occurred (2.6%). The P-RAC score was found to differ statistically from the RENAL score (t = 3.754, df = 44, P = .001). A positive correlation was found between the P-RAC score and number of antenna insertions (r = .378, n = 45, P = .011) and procedure duration (r = .328, n = 45, P = .028). No correlation was found between the RENAL score and number of MW antenna insertions (r = .110, n = 45, P = .472) or procedure duration (r = .263, n = 45, P = .081). Hydrodissection was significantly more common in the P-RAC high-complexity category than in low-complexity category (χ 2 = 12.073, df = 2, P = .002). The P-RAC score may be useful in stratifying percutaneous renal ablation complexity. Further studies with larger sample sizes are necessary to validate the P-RAC score and to determine if it can predict risk of complications. Copyright © 2016 SIR. Published by Elsevier Inc. All rights reserved.
2013-01-01
Background. Lower ambulatory performance with aging may be related to a reduced oxidative capacity within skeletal muscle. This study examined the associations between skeletal muscle mitochondrial capacity and efficiency with walking performance in a group of older adults. Methods. Thirty-seven older adults (mean age 78 years; 21 men and 16 women) completed an aerobic capacity (VO2 peak) test and measurement of preferred walking speed over 400 m. Maximal coupled (State 3; St3) mitochondrial respiration was determined by high-resolution respirometry in saponin-permeabilized myofibers obtained from percutanous biopsies of vastus lateralis (n = 22). Maximal phosphorylation capacity (ATPmax) of vastus lateralis was determined in vivo by 31P magnetic resonance spectroscopy (n = 30). Quadriceps contractile volume was determined by magnetic resonance imaging. Mitochondrial efficiency (max ATP production/max O2 consumption) was characterized using ATPmax per St3 respiration (ATPmax/St3). Results. In vitro St3 respiration was significantly correlated with in vivo ATPmax (r 2 = .47, p = .004). Total oxidative capacity of the quadriceps (St3*quadriceps contractile volume) was a determinant of VO2 peak (r 2 = .33, p = .006). ATPmax (r 2 = .158, p = .03) and VO2 peak (r 2 = .475, p < .0001) were correlated with preferred walking speed. Inclusion of both ATPmax/St3 and VO2 peak in a multiple linear regression model improved the prediction of preferred walking speed (r 2 = .647, p < .0001), suggesting that mitochondrial efficiency is an important determinant for preferred walking speed. Conclusions. Lower mitochondrial capacity and efficiency were both associated with slower walking speed within a group of older participants with a wide range of function. In addition to aerobic capacity, lower mitochondrial capacity and efficiency likely play roles in slowing gait speed with age. PMID:23051977
Coen, Paul M; Jubrias, Sharon A; Distefano, Giovanna; Amati, Francesca; Mackey, Dawn C; Glynn, Nancy W; Manini, Todd M; Wohlgemuth, Stephanie E; Leeuwenburgh, Christiaan; Cummings, Steven R; Newman, Anne B; Ferrucci, Luigi; Toledo, Frederico G S; Shankland, Eric; Conley, Kevin E; Goodpaster, Bret H
2013-04-01
Lower ambulatory performance with aging may be related to a reduced oxidative capacity within skeletal muscle. This study examined the associations between skeletal muscle mitochondrial capacity and efficiency with walking performance in a group of older adults. Thirty-seven older adults (mean age 78 years; 21 men and 16 women) completed an aerobic capacity (VO2 peak) test and measurement of preferred walking speed over 400 m. Maximal coupled (State 3; St3) mitochondrial respiration was determined by high-resolution respirometry in saponin-permeabilized myofibers obtained from percutanous biopsies of vastus lateralis (n = 22). Maximal phosphorylation capacity (ATPmax) of vastus lateralis was determined in vivo by (31)P magnetic resonance spectroscopy (n = 30). Quadriceps contractile volume was determined by magnetic resonance imaging. Mitochondrial efficiency (max ATP production/max O2 consumption) was characterized using ATPmax per St3 respiration (ATPmax/St3). In vitro St3 respiration was significantly correlated with in vivo ATPmax (r (2) = .47, p = .004). Total oxidative capacity of the quadriceps (St3*quadriceps contractile volume) was a determinant of VO2 peak (r (2) = .33, p = .006). ATPmax (r (2) = .158, p = .03) and VO2 peak (r (2) = .475, p < .0001) were correlated with preferred walking speed. Inclusion of both ATPmax/St3 and VO2 peak in a multiple linear regression model improved the prediction of preferred walking speed (r (2) = .647, p < .0001), suggesting that mitochondrial efficiency is an important determinant for preferred walking speed. Lower mitochondrial capacity and efficiency were both associated with slower walking speed within a group of older participants with a wide range of function. In addition to aerobic capacity, lower mitochondrial capacity and efficiency likely play roles in slowing gait speed with age.
Lahvis, G P; Wells, R S; Kuehl, D W; Stewart, J L; Rhinehart, H L; Via, C S
1995-01-01
Since 1987, large-scale mortalities of dolphins have been reported along the Atlantic coast of North America, in the Gulf of Mexico, and in the Mediterranean Sea. Autopsied bottlenose dolphins, Tursiops truncatus, which were collected from the large-scale mortality along the Atlantic coast in 1987 to 1988, exhibited opportunistic infections indicative of immune dysfunction. Further, these animals had high levels of chlorinated hydrocarbons, such as PCBs and DDT, that can suppress immune functions. The purpose of this study was to determine whether there is a relationship between chemical contaminant exposure and immune response in free-ranging dolphins. In June of 1991, peripheral blood was obtained from members of a bottlenose dolphin population that resides along the west coast of Florida. Peripheral blood lymphocyte responses to Concanavalin A (Con A) and phytohemagglutinin (PHA) were determined in vitro and compared by regression analysis with contaminant concentrations in whole blood from a small subset of these animals (n = 5). These data indicate that a reduced immune response in these bottlenose dolphins was correlated with increasing whole blood concentrations of several contaminants. Specifically, inverse correlations were found between Con A-induced lymphocyte proliferation and tetrachlorinated to octachlorinated biphenyls (r2 values ranged from 0.70 to 0.87). Con A-induced lymphocyte responses also correlated inversely with p,p'DDT (r2 values of 0.73 and 0.79); o.p'-DDE (r2 values of 0.93 and 0.96); and p,p'-DDE (r2 values of 0.73 and 0.81). PMID:7556026
Skipworth, R J E; Deans, D A C; Tan, B H L; Sangster, K; Paterson-Brown, S; Brown, D A; Hunter, M; Breit, S N; Ross, J A; Fearon, K C H
2010-02-16
Macrophage inhibitory cytokine-1(MIC-1) is a potential modulator of systemic inflammation and nutritional depletion, both of which are adverse prognostic factors in oesophago-gastric cancer (OGC). Plasma MIC-1, systemic inflammation (defined as plasma C-reactive protein (CRP) of > or =10 mg l(-1) or modified Glasgow prognostic score (mGPS) of > or =1), and nutritional status were assessed in newly diagnosed OGC patients (n=293). Healthy volunteers (n=35) served as controls. MIC-1 was elevated in patients (median=1371 pg ml(-1); range 141-39 053) when compared with controls (median=377 pg ml(-1); range 141-3786; P<0.001). Patients with gastric tumours (median=1592 pg ml(-1); range 141-12 643) showed higher MIC-1 concentrations than patients with junctional (median=1337 pg ml(-1); range 383-39 053) and oesophageal tumours (median=1180 pg ml(-1); range 258-31 184; P=0.015). Patients showed a median weight loss of 6.4% (range 0.0-33.4%), and 42% of patients had an mGPS of > or =1 or plasma CRP of > or =10 mg l(-1) (median=9 mg l(-1); range 1-200). MIC-1 correlated positively with disease stage (r(2)=0.217; P<0.001), age (r(2)=0.332; P<0.001), CRP (r(2)=0.314; P<0.001), and mGPS (r(2)=0.336; P<0.001), and negatively with Karnofsky Performance Score (r(2)=-0.269; P<0.001). However, although MIC-1 correlated weakly with dietary intake (r(2)=0.157; P=0.031), it did not correlate with weight loss, BMI, or anthropometry. Patients with MIC-1 levels in the upper quartile showed reduced survival (median=204 days; 95% CI 157-251) when compared with patients with MIC-1 levels in the lower three quartiles (median=316 days; 95% CI 259-373; P=0.036), but MIC-1 was not an independent prognostic indicator. There is no independent link between plasma MIC-1 levels and depleted nutritional status or survival in OGC.
Cheng, Ta-Chun; Tung, Yi-Ching; Chu, Pei-Yu; Chuang, Chih-Hung; Hsieh, Yuan-Chin; Huang, Chien-Chiao; Wang, Yeng-Tseng; Kao, Chien-Han; Roffler, Steve R.; Cheng, Tian-Lu
2016-01-01
Molecular weight markers that can tolerate denaturing conditions and be auto-detected by secondary antibodies offer great efficacy and convenience for Western Blotting. Here, we describe M&R LE protein markers which contain linear epitopes derived from the heavy chain constant regions of mouse and rabbit immunoglobulin G (IgG Fc LE). These markers can be directly recognized and stained by a wide range of anti-mouse and anti-rabbit secondary antibodies. We selected three mouse (M1, M2 and M3) linear IgG1 and three rabbit (R1, R2 and R3) linear IgG heavy chain epitope candidates based on their respective crystal structures. Western blot analysis indicated that M2 and R2 linear epitopes are effectively recognized by anti-mouse and anti-rabbit secondary antibodies, respectively. We fused the M2 and R2 epitopes (M&R LE) and incorporated the polypeptide in a range of 15–120 kDa auto-detecting markers (M&R LE protein marker). The M&R LE protein marker can be auto-detected by anti-mouse and anti-rabbit IgG secondary antibodies in standard immunoblots. Linear regression analysis of the M&R LE protein marker plotted as gel mobility versus the log of the marker molecular weights revealed good linearity with a correlation coefficient R2 value of 0.9965, indicating that the M&R LE protein marker displays high accuracy for determining protein molecular weights. This accurate, regular and auto-detected M&R LE protein marker may provide a simple, efficient and economical tool for protein analysis. PMID:27494183
Lin, Wen-Wei; Chen, I-Ju; Cheng, Ta-Chun; Tung, Yi-Ching; Chu, Pei-Yu; Chuang, Chih-Hung; Hsieh, Yuan-Chin; Huang, Chien-Chiao; Wang, Yeng-Tseng; Kao, Chien-Han; Roffler, Steve R; Cheng, Tian-Lu
2016-01-01
Molecular weight markers that can tolerate denaturing conditions and be auto-detected by secondary antibodies offer great efficacy and convenience for Western Blotting. Here, we describe M&R LE protein markers which contain linear epitopes derived from the heavy chain constant regions of mouse and rabbit immunoglobulin G (IgG Fc LE). These markers can be directly recognized and stained by a wide range of anti-mouse and anti-rabbit secondary antibodies. We selected three mouse (M1, M2 and M3) linear IgG1 and three rabbit (R1, R2 and R3) linear IgG heavy chain epitope candidates based on their respective crystal structures. Western blot analysis indicated that M2 and R2 linear epitopes are effectively recognized by anti-mouse and anti-rabbit secondary antibodies, respectively. We fused the M2 and R2 epitopes (M&R LE) and incorporated the polypeptide in a range of 15-120 kDa auto-detecting markers (M&R LE protein marker). The M&R LE protein marker can be auto-detected by anti-mouse and anti-rabbit IgG secondary antibodies in standard immunoblots. Linear regression analysis of the M&R LE protein marker plotted as gel mobility versus the log of the marker molecular weights revealed good linearity with a correlation coefficient R2 value of 0.9965, indicating that the M&R LE protein marker displays high accuracy for determining protein molecular weights. This accurate, regular and auto-detected M&R LE protein marker may provide a simple, efficient and economical tool for protein analysis.
NASA Astrophysics Data System (ADS)
Ha, Sang Bu; Cho, Pyeong-Seok; Cho, Yoon Ho; Lee, Dokyol; Lee, Jong-Heun
A range of La 0.75Sr 0.25Cr 0.5Mn 0.5O 3- δ (LSCM) powders is prepared by the carbonate coprecipitation method for use as anodes in solid oxide fuel cells. The supersaturation ratio (R = [(NH 4) 2CO 3]/([La 3+] + [Sr 2+] + [Cr 3+] + [Mn 2+])) during the coprecipitation determines the relative compositions of La, Sr, Cr, and Mn. The composition of the precursor approaches the stoichiometric one at the supersaturation range of 4 ≤ R ≤ 12.5, whereas Sr and Mn components are deficient at R < 4 and excessive at R = 25. The fine and phase-pure LSCM powders are prepared by heat treatment at very low temperature (1000 °C) at R = 7.5 and 12.5. By contrast, the solid-state reaction requires a higher heat-treatment temperature (1400 °C). The catalytic activity of the LSCM electrodes is enhanced by using carbonate-derived powders to manipulate the electrode microstructures.
Kamalzadeh, Zahra; Babanezhad, Esmaeil; Ghaffari, Solmaz; Mohseni Ezhiyeh, Alireza; Mohammadnejad, Mahdieh; Naghibfar, Mehdi; Bararjanian, Morteza; Attar, Hossein
2017-08-01
A new, normal phase high performance liquid chromatography (NP-HPLC) method was developed for separation of Bortezomib (BZB) enantiomers and quantitative determination of (1S,2R)-enantiomer of BZB in active pharmaceutical ingredient (API) samples. The developed method was validated based on International Conference on Harmonisation (ICH) guidelines and it was proved to be accurate, precise and robust. The obtained resolution (RS) between the enantiomers was more than 2. The calibration curve for (1S,2R)-enantiomer was found to be linear in the concentration range of 0.24-5.36 mg/L with regression coefficient (R2) of 0.9998. Additionally, the limit of detection (LOD) and limit of quantification (LOQ) were 0.052 and 0.16 mg/L, respectively. Also, in this study, a precise, sensitive and robust gradient reversed-phase HPLC (RP-HPLC) method was developed and validated for determination of BZB in API samples. The detector response was linear over the concentration range of 0.26-1110.5 mg/L. The values of R2, LOD and LOQ were 0.9999, 0.084 and 0.25 mg/L, respectively. For both NP-HPLC and RP-HPLC methods, all of the RSD (%) values obtained in the precision study were <1.0%. System suitability parameters in terms of tailing factor (TF), number of theoretical plates (N) and RS were TF < 2.0, N > 2,000 and RS > 2.0. The performance of two common integration methods of valley to valley and drop perpendicular for drawing the baseline between two adjacent peaks were investigated for the determination of diastereomeric impurity (Imp-D) in the BZB-API samples. The results showed that the valley to valley method outperform the drop perpendicular method for calculation of Imp-D peak areas. Therefore, valley to valley method was chosen for peak integration. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
NASA Technical Reports Server (NTRS)
Alexander, W. M.; Goad, S.; Mcdonald, R. A.; Tanner, W. G., Jr.; Pollock, J. J.
1989-01-01
The Dust Impact Detection System (DIDSY) aboard the Giotto spacecraft provided the information on the dust flux, mass spectrum, and cumulative mass distribution flux in the coma of Comet Halley. Analysis of discrete pulse height data of cometary particles for the mass range of particles between 4.0 x 10 to the -10th g and 6.0 x 10 to the -6th g registered by the Giotto DIDSY detectors 2, 3, and 4 has been completed, and a cumulative flux has been determined for this size range of particles. Inside the cometopause, anomalous peaks have been identified as deviation from a 1/R-squared curve in both pre- and postencounter measurements.
Nieto, Sonia; Arnau, Palmira; Serrano, Elena; Navarro, Rafael; Soler, Tatiana; Cativiela, Carlos; Urriolabeitia, Esteban P
2009-12-21
The ortho functionalization of methyl R-phenylglycinate has been easily achieved using the known orthopalladated complex [Pd(mu-Cl){R-C(6)H(4)(CH(CO(2)Me)NH(2))-2}](2) (1) as synthetic tool. Different functional groups have been introduced at the ortho position of the aryl ring. The reaction of (R)-1 with X(2) or PhI(OAc)(2) gives XC(6)H(4)(CH(CO(2)Me)NH(2))-2 (X = I, Br, OMe, OEt) through oxidative coupling, while the reaction with CO gives an isoindolone. (R)-1 also reacts with one, two, or three alkyne molecules to give different metal-containing or metal-free heterocycles. The resulting functionalized amino esters or heterocycles retain the chirality of (R)-1, according with the values of the optical rotation and the obtained ee values ranging from 22%-87%. The X-ray structures of six representative compounds have also been determined.
The First Empirical Determination of the Fe10+ and Fe13+ Freeze-in Distances in the Solar Corona
NASA Astrophysics Data System (ADS)
Boe, Benjamin; Habbal, Shadia; Druckmüller, Miloslav; Landi, Enrico; Kourkchi, Ehsan; Ding, Adalbert; Starha, Pavel; Hutton, Joseph
2018-06-01
Heavy ions are markers of the physical processes responsible for the density and temperature distribution throughout the fine-scale magnetic structures that define the shape of the solar corona. One of their properties, whose empirical determination has remained elusive, is the “freeze-in” distance (R f ) where they reach fixed ionization states that are adhered to during their expansion with the solar wind. We present the first empirical inference of R f for {Fe}}{10+} and {Fe}}{13+} derived from multi-wavelength imaging observations of the corresponding Fe XI ({Fe}}{10+}) 789.2 nm and Fe XIV ({Fe}}{13+}) 530.3 nm emission acquired during the 2015 March 20 total solar eclipse. We find that the two ions freeze-in at different heliocentric distances. In polar coronal holes (CHs) R f is around 1.45 R ⊙ for {Fe}}{10+} and below 1.25 R ⊙ for {Fe}}{13+}. Along open field lines in streamer regions, R f ranges from 1.4 to 2 R ⊙ for {Fe}}{10+} and from 1.5 to 2.2 R ⊙ for {Fe}}{13+}. These first empirical R f values: (1) reflect the differing plasma parameters between CHs and streamers and structures within them, including prominences and coronal mass ejections; (2) are well below the currently quoted values derived from empirical model studies; and (3) place doubt on the reliability of plasma diagnostics based on the assumption of ionization equilibrium beyond 1.2 R ⊙.
Nettles, Charles B; Zhou, Yadong; Zou, Shengli; Zhang, Dongmao
2016-03-01
Demonstrated herein is a UV-vis Ratiometric Resonance Synchronous Spectroscopic (R2S2, pronounced as "R-two-S-two" for simplicity) technique where the R2S2 spectrum is obtained by dividing the resonance synchronous spectrum of a NP-containing solution by the solvent resonance synchronous spectrum. Combined with conventional UV-vis measurements, this R2S2 method enables experimental quantification of the absolute optical cross sections for a wide range of molecular and nanoparticle (NP) materials that range optically from pure photon absorbers or scatterers to simultaneous photon absorbers and scatterers, simultaneous photon absorbers and emitters, and all the way to simultaneous photon absorbers, scatterers, and emitters in the UV-vis wavelength region. Example applications of this R2S2 method were demonstrated for quantifying the Rayleigh scattering cross sections of solvents including water and toluene, absorption and resonance light scattering cross sections for plasmonic gold nanoparticles, and absorption, scattering, and on-resonance fluorescence cross sections for semiconductor quantum dots (Qdots). On-resonance fluorescence quantum yields were quantified for the model molecular fluorophore Eosin Y and fluorescent Qdots CdSe and CdSe/ZnS. The insights and methodology presented in this work should be of broad significance in physical and biological science research that involves photon/matter interactions.
[Determination of carvacrol and thymol in Mosla chinensis by HPLC].
Ji, Li; Wang, Fang; Liu, Yuan-yan; Tong, Yan; Li, Xian-duan; Feng, Xue-feng; Huang, Lu-qi; Zhou, Guo-ping
2004-11-01
To establish a quantitative method of determination of carvacrol and thymol in Mosla chinensis. The sample was extracted with 95% ethanol, ODS column was used with methanol-water-acetic acid (60:40:2) as mobile phase. The detection wavelength was set at 274 nm. The linearities of carvacrol and thymol were respectively in the range of 0.23-2.15 microg (r = 0.9999) and 0.39-2.36 microg (r = 0.9999); the average recoveries were 99.9% (RSD 1.4%) and 98.6% (RSD 1.3%); the RSD of repeatability were 1.1% and 1.6%. The method is reliable, and can be used for quality control of M. chinensis.
Evaluation of quick tests for phosphorus determination in dairy manures.
Lugo-Ospina, A; Dao, Thanh H; Van Kessel, J A; Reeves, J B
2005-05-01
Nutrients in animal manure are valuable inputs in agronomic crop production. Rapid and timely information about manure nutrient content are needed to minimize the risks of phosphorus (P) over-application and losses of dissolved P (DP) in runoff from fields treated with manure. We evaluated the suitability of a commercial hand-held reflectometer, a hydrometer, and an electrical conductivity (EC) meter for determining DP and total P (TP) in dairy manures. Bulk samples (n = 107) collected from farms across CT, MD, NY, PA, and VA were highly variable in total solids (TS) concentration, ranging from 11 to 213gL(-1), in suspensions' pH (6.3-9.2), and EC (6.2-53.3 dS m(-1)). Manure DP concentrations measured using the RQFlex reflectometer (RQFlex-DP(s)) were related to molybdate-reactive P (MRP(s)) concentrations as follows: RQFlex-DP(s) = 0.471 x MRP(s) + 1102 (r2 = 0.29). Inclusion of pH and squared-pH terms improved the prediction of manure DP from RQFlex results (r2 = 0.66). Excluding five outlier samples that had pH < or = 6.9 the coefficient of determination (r2) for the MRP(s) and RQFlex-DP(s) relationship was 0.83 for 95% of the samples. Manure TS were related to hydrometer specific gravity readings (r2 = 0.53) that were in turn related to TP (r2 = 0.34), but not to either RQFlex-DP or MRP. Relationships between suspensions' EC and DP or TP were non-significant. Therefore, the RQFlex method is the only viable option for on-site quick estimates of DP that can be made more robust when complemented with TS and pH measurements. The DP quick test can provide near real-time information on soluble manure nutrient content across a wide range of handling and storage conditions on dairy farms and quick estimates of potential soluble P losses in runoff following land applications of manure.
NASA Astrophysics Data System (ADS)
Jones, R. T.; McGlynn, B. L.; McDermott, T.; Dore, J. E.
2015-12-01
Gas concentrations (CH4, CO2, N2O, and O2), soil properties (soil water content and pH), and microbial community composition were measured from soils at 32 sites across the Stringer Creek Watershed in the Tenderfoot Creek Experimental Forest 7 times between June 3, 2013 and September 20, 2013. Soils were fully saturated during the initial sampling period and dried down over the course of the summer. Soils and gas were sampled from 5cm and 20cm at each site and also at 50cm at eight riparian sites. In total, 496 individual soil samples were collected. Soil moisture ranged from 3.7% to fully saturated; soil pH ranged from 3.60 to 6.68. Methane concentrations in soils ranged from 0.426 ppm to 218 ppm; Carbon dioxide concentrations ranged from 550 ppm to 42,990 ppm; Nitrous oxide concentrations ranged from 0.220 ppm to 2.111 ppm; Oxygen concentrations ranged from 10.2% to 21.5%. Soil microbial communities were characterized by DNA sequences covering the V4 region of the 16S rRNA gene. DNA sequences were generated (~30,000,000 sequences) from the 496 soil samples using the Illumina MiSeq platform. Operational Taxonomic Units were generated using USEARCH, and representative sequences were taxonomically classified according the Ribosomal Database Project's taxonomy scheme. Analysis of similarity revealed that microbial communities found within a landscape type (high upland forest, low upland forest, riparian) were more similar than among landscape types (R = 0.600; p<0.001). Similarly, communities from unique site x depths were similar across the 7 collection periods (R = 0.646; p<0.001) despite changes in soil moisture. Euclidean distances of soil properties and gas concentrations were compared to Bray-Curtis community dissimilarity matrices using Mantel tests to determine how community structure co-varies with the soil environment and gas concentrations. All variables measured significantly co-varied with microbial community membership (pH: R = 0.712, p < 0.001; CO2: R = 0.578, p < 0.001; O2: R = 0.517, p < 0.001; Soil moisture: R = 0.408, p < 0.001; N2O: R = 0.218, p = 0.003; CH4: R = 0.195, p = 0.008). Despite the rather low co-variation between methane concentrations and microbial community composition, relative abundances of methanotrophic and methanogenic lineages did co-vary strongly with methane concentrations.
Method to determine the true modulation ratio for comprehensive two-dimensional gas chromatography.
Pinkerton, David K; Parsons, Brendon A; Synovec, Robert E
2016-12-09
A new method is presented to determine the true modulation ratio, M R , from the measurable effective modulation ratio, M R *, in comprehensive two-dimensional gas chromatography, GC×GC, without the requirement for a detector at the end of the primary column. The method was developed through the investigation of modulator induced band broadening, as a function of 1 W b and the selected modulation period, P M , for simulated GC×GC data, by first defining primary column 1 D peak(s) and simulating the modulation process. Gaussian curve fitting is used to model each modulated secondary column separation peaklet, 2 D, in the unfolded GC×GC data to accurately determine the maxima of the peaklet distribution, followed by Gaussian curve fitting to the maxima to determine the effective 1 D peak profile and width, 1 W b *. The relationship between 1 W b and 1 W b * is studied as a function of the effective modulation ratio, M R *, which is 1 W b * divided by P M , in order to determine the true modulation ratio, M R , which is 1 W b divided by P M . We explore how peak sampling phase (in-phase and out-of-phase) plays a role in the relationship between M R and M R *. Experimental validation of the simulated results is also provided, to span a range of commonly implemented conditions with typical 1 W b (2-4.5s) and P M (0.25-8s). Use of M R <2 significantly broadens the 1 D peak (M R *≥1.2M R ) corresponding to a loss in 1 D peak capacity, 1 n c ≥20%. The new method relies upon mapping from M R * to M R , which is discussed in relation to peak capacity theories for GC×GC. It is found that optimizing 1 n c in GC×GC requires that 1 W b is minimized and must be sampled with a sufficiently short P M (1-2s) to minimize modulator induced band broadening and a subsequent reduction in the effective 1 D peak capacity. Copyright © 2016 Elsevier B.V. All rights reserved.
Robbins, Rebecca J; Leonczak, Jadwiga; Li, Julia; Johnson, J Christopher; Collins, Tom; Kwik-Uribe, Catherine; Schmitz, Harold H
2012-01-01
An international collaborative study was conducted on an HPLC method with fluorescent detection (FLD) for the determination of flavanols and procyanidins in materials containing chocolate and cocoa. The sum of the oligomeric fractions with degree of polymerization 1-10 was the determined content value. Sample materials included dark and milk chocolates, cocoa powder, cocoa liquors, and cocoa extracts. The content ranged from approximately 2 to 500 mg/g (defatted basis). Thirteen laboratories representing commercial, industrial, and academic institutions in six countries participated in the study. Fourteen samples were sent as blind duplicates to the collaborators. Results from 12 laboratories yielded repeatability relative standard deviation (RSDr) values that were below 10% for all materials analyzed, ranging from 4.17 to 9.61%. The reproducibility relative standard deviation (RSD(R)) values ranged from 5.03 to 12.9% for samples containing 8.07 to 484.7 mg/g. In one sample containing a low content of flavanols and procyanidins (approximately 2 mg/g), the RSD(R) was 17.68%. Based on these results, the method is recommended for Official First Action for the determination of flavanols and procyanidins in chocolate, cocoa liquors, powder(s), and cocoa extracts.
Long-Range Planning Can Improve the Efficiency of Agricultural Research and Development.
1981-07-24
planning is not done » Conclusions Recommendat ion Agency comments ADVISORY BODIES HAVE HAD MIXED SUCCESS IN AFFECTING LONG-RANGE PLANNING... kfc r Their efforts have more impact on determining priorities for the short-range budgeting cycle rather than influencing development of long...cultural products, (2) developing an efficient marketing and processing system, (3) conserving natural resources, and (4) im- proving the well-being of
Houwink, Annemieke; Geerdink, Yvonne A; Steenbergen, Bert; Geurts, Alexander C H; Aarts, Pauline B M
2013-01-01
To investigate the validity and reliability of the revised Video-Observation Aarts and Aarts module: Determine Developmental Disregard (VOAA-DDD-R). Upper-limb capacity and performance were assessed in children with unilateral spastic cerebral palsy (CP) by measuring overall duration of affected upper-limb use and the frequency of specific behaviours during a task in which bimanual activity was demanded ('stringing beads') and stimulated ('decorating a muffin'). Developmental disregard was defined as the difference in duration of affected upper-limb use between both tasks. Raters were two occupational and one physical therapist who received 3 hours of training. Construct validity was determined by comparing children with CP with typically developing children. Intrarater, interrater, and test-retest reliability were determined using the intraclass correlation coefficient. Standard errors of measurement and smallest detectable differences were also calculated. Twenty-five children with CP (15 females, 10 males; mean age 4 y 9 mo [SD 1 y 7 mo], range 2 y 9 mo-8 y; Manual Ability Classification System levels I-III) scored lower on capacity (p=0.052) and performance (p<0.001), and higher on developmental disregard (p<0.001) than 46 age- and sex-matched typically developing children (23 males; mean age 5 y 3 mo [SD 1 y 5 mo], range 2 y 6 mo-8 y). The intraclass correlation coefficients (0.79-1.00) indicated good reliability. Absolute agreement was high, standard errors of measurement ranged from 4.5 to 6.8%, and smallest detectable differences ranged from 12.5 to 19.0%. The VOAA-DDD-R can be reliably and validly used by occupational and physical therapists to assess upper-limb capacity, performance, and developmental disregard in children (2 y 6 mo-8 y) with CP. © The Authors. Developmental Medicine & Child Neurology © 2012 Mac Keith Press.
Gitelson, Anatoly A; Gritz, Yuri; Merzlyak, Mark N
2003-03-01
Leaf chlorophyll content provides valuable information about physiological status of plants. Reflectance measurement makes it possible to quickly and non-destructively assess, in situ, the chlorophyll content in leaves. Our objective was to investigate the spectral behavior of the relationship between reflectance and chlorophyll content and to develop a technique for non-destructive chlorophyll estimation in leaves with a wide range of pigment content and composition using reflectance in a few broad spectral bands. Spectral reflectance of maple, chestnut, wild vine and beech leaves in a wide range of pigment content and composition was investigated. It was shown that reciprocal reflectance (R lambda)-1 in the spectral range lambda from 520 to 550 nm and 695 to 705 nm related closely to the total chlorophyll content in leaves of all species. Subtraction of near infra-red reciprocal reflectance, (RNIR)-1, from (R lambda)-1 made index [(R lambda)(-1)-(RNIR)-1] linearly proportional to the total chlorophyll content in spectral ranges lambda from 525 to 555 nm and from 695 to 725 nm with coefficient of determination r2 > 0.94. To adjust for differences in leaf structure, the product of the latter index and NIR reflectance [(R lambda)(-1)-(RNIR)-1]*(RNIR) was used; this further increased the accuracy of the chlorophyll estimation in the range lambda from 520 to 585 nm and from 695 to 740 nm. Two independent data sets were used to validate the developed algorithms. The root mean square error of the chlorophyll prediction did not exceed 50 mumol/m2 in leaves with total chlorophyll ranged from 1 to 830 mumol/m2.
Enrichment of Thorium (Th) and Lead (Pb) in the early Galaxy
NASA Astrophysics Data System (ADS)
Aoki, Wako; Honda, Satoshi
2010-03-01
We have been determining abundances of Th, Pb and other neutron-capture elements in metal-deficient cool giant stars to constrain the enrichment of heavy elements by the r- and s-processes. Our current sample covers the metallicity range between [Fe/H] = -2.5 and -1.0. (1) The abundance ratios of Pb/Fe and Pb/Eu of most of our stars are approximately constant, and no increase of these ratios with increasing metallicity is found. This result suggests that the Pb abundances of our sample are determined by the r-process with no or little contribution of the s-process. (2) The Th/Eu abundance ratios of our sample show no significant scatter, and the average is lower by 0.2 dex in the logarithmic scale than the solar-system value. This result indicates that the actinides production by the r-process does not show large dispersion, even though r-process models suggest high sensitivity of the actinides production to the nucleosynthesis environment.
2003-11-01
klick on File TL-03- uGC -Model.xls Model 2. Determination of Peak Capacity for 0.1 < k’ < 5. This tool was intended to help with the determination of peak...dependent on the agreed k’ range, i.e. the associated boiling point range. Double-klick on File TL-03- uGC -Model.xls Model 3. Estimation of the Fraction...available today on the market .6 Figure 6 is a 2 second GC chromatogram of 7 test compounds using the 100 micron square capillary column (see Figure 4
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hranisavljevic, J.; Michael, J.V.
1998-09-24
The shock tube technique coupled with H-atom atomic resonance absorption spectrometry has been used to study the reactions (1) CF{sub 3} + H{sub 2} {r_arrow} CF{sub 3}H + H and (2) CF{sub 3}H + H {r_arrow} CF{sub 3} + H{sub 2} over the temperature ranges 1168--1673 K and 1111--1550 K, respectively. The results can be represented by the Arrhenius expressions k{sub 1} = 2.56 {times} 10{sup {minus}11} exp({minus}8549K/T) and k{sub 2} = 6.13 {times} 10{sup {minus}11} exp({minus}7364K/T), both in cm{sup 3} molecule{sup {minus}1} s{sup {minus}1}. Equilibrium constants were calculated from the two Arrhenius expressions in the overlapping temperature range, andmore » good agreement was obtained with the literature values. The rate constants for reaction 2 were converted into rate constants for reaction 1 using literature equilibrium constants. These data are indistinguishable from direct k{sub 1} measurements, and an Arrhenius fit for the joint set is k{sub 1} = 1.88 {times} 10{sup {minus}11} exp({minus}8185K/T) cm{sup 3} molecule{sup {minus}1} s{sup {minus}1}. The CF{sub 3} + H{sub 2} {r_arrow} CF{sub 3}H + H reaction was further modeled using conventional transition-state theory, which included ab initio electronic structure determinations of reactants, transition state, and products.« less
Potts, Jennifer C; Burton, Michael L; Myers, Amanda R
2016-01-01
Ages of schoolmaster ( n = 136) from the southeastern Florida coast from 1981-2015 were determined using sectioned sagittal otoliths. Opaque zones were annular, forming March-July (peaking in May-June). Schoolmaster ranged in age from 1-42 years; the largest fish measured 505 mm total length (TL) and was 19 years old. The oldest fish measured 440 mm TL. Estimated body size relationships for schoolmaster were: W = 9.26 × 10 -6 TL 3.11 ( n = 256, r 2 = 0.95); W = 2.13 × 10 -5 FL 2.99 ( n = 161, r 2 = 0.95); TL = 1.03 FL + 10.36 ( n = 143, r 2 = 0.99); and FL = 0.96 TL - 8.41 ( n = 143, r 2 = 0.99), where W = whole weight in g, FL = fork length in mm, and TL in mm. The fitted von Bertalanffy growth equation was: L t = 482 (1 - e -0.12( t +2.79) ) ( n = 136). Based on published life history relationships, a point estimate of natural mortality for schoolmaster was M = 0.10, while age-specific estimates of M ranged from 1.57-0.18 for ages 1-42.
Structural and magnetic properties of RTiNO{sub 2} (R=Ce, Pr, Nd) perovskite nitride oxides
DOE Office of Scientific and Technical Information (OSTI.GOV)
Porter, Spencer H.; Huang, Zhenguo, E-mail: zhenguo@uow.edu.au; Cheng, Zhenxiang
2015-03-15
Neutron powder diffraction indicates that CeTiNO{sub 2} and PrTiNO{sub 2} crystallize with orthorhombic Pnma symmetry (Ce: a=5.5580(5), b=7.8369(7), and c=5.5830(4) Å; Pr: a=5.5468(5), b=7.8142(5), and c=5.5514(5) Å) as a result of a{sup –}b{sup +}a{sup –} tilting of the titanium-centered octahedra. Careful examination of the NPD data, confirms the absence of long range anion order in both compounds, while apparent superstructure reflections seen in electron diffraction patterns provide evidence for short range anion order. Inverse magnetic susceptibility plots reveal that the RTiNO{sub 2} (R=Ce, Pr, Nd) compounds are paramagnetic with Weiss constants that vary from −28 to −42 K. Effective magneticmore » moments for RTiNO{sub 2} (R=Ce, Pr, Nd) are 2.43 μ{sub B}, 3.63 μ{sub B}, and 3.47 μ{sub B}, respectively, in line with values expected for free rare-earth ions. Deviations from Curie–Weiss behavior that occur below 150 K for CeTiNO{sub 2} and below 30 K for NdTiNO{sub 2} are driven by magnetic anisotropy, spin–orbit coupling, and crystal field effects. - Graphical abstract: The structure and magnetism of the oxide nitride perovskites RTiNO{sub 2} (R=Ce, Pr, Nd) have been explored. The average symmetry is shown to be Pnma with a random distribution of oxide and nitride ions and a{sup −}b{sup +}a{sup −} tilting of the titanium-centered octahedra, but electron diffraction shows evidence for short range anion order. All three compounds are paramagnetic but deviations from the Curie Weiss law are seen below 150 K for R=Ce and below 30 K for R=Nd. - Highlights: • The oxide nitride perovskites RTiNO{sub 2} (R=Ce, Pr) have been prepared and their structures determined. • Diffraction measurements indicate short range cis-order of O and N, but no long range order. • Compounds are paramagnetic with Weiss constants that vary from −28 to −42 K. • CeTiO{sub 2}N and NdTiO{sub 2}N deviate from Curie–Weiss behavior below 150 and 30 K, respectively.« less
Direct Determination of Range from Current Nuclear Overpressure Equations
1988-03-01
residual), a term that takes into account the fact that the model does not exactly describe the behavior of the data. A quadratic (second degree) two...HZ1,HZ2,HZ3,HRY,HZRY,MY1,MY2,MY REAL NY,PS1,PS2,PS3, PS4 ,PS,GR,H,M,DEN C C CREATE A NEW FILE, TRIAL1.DAT, TO STORE THE DATA. C OPEN(32,FILE=’TRIALI.DAT...47/(R**AZ) PS3-(DZ*EZ)/(l+FZ*R**GZ) PS4 =MY/ (R**NY) .5, PS=PS1+PS2+PS3+HZRYIPS4 a, C a’C WRITE THE DATA TO FILE 32 USING FORMAT 100 STATEMENT. * C
Sweat, J M; Johnson, C M; Marikar, Y; Gibbs, E P
2005-12-15
An in vitro system to determine surface interleukin-2 receptor (IL-2R) expression on mitogen-stimulated peripheral blood mononuclear cells (PBMC) from free-ranging manatees, Trichechus manatus latirostris was developed. Human recombinant IL-2, conjugated with a fluorescein dye was used in conjunction with flow cytometric analysis to determine changes in surface expression of IL-2R at sequential times over a 48-h period of in vitro stimulation. Surface expression of IL-2R was detected on manatee PBMC, which also cross-reacted with an anti-feline pan T-cell marker. An expression index (EI) was calculated by comparing mitogen-activated and non-activated PBMC. Based on side- and forward-scatter properties, flow cytometric analysis showed an increase in the number of larger, more granular "lymphoblasts" following concanavalin A (Con A) stimulation. The appearance of lymphoblasts was correlated with an increase in their surface expression of IL-2 receptors. Surface IL-2R expression, in Con A-stimulated PBMC, was detected at 16 h, peaked at 24-36 h, and began to decrease by 48 h. Characterization of the IL-2R expression should provide additional information on the health status of manatees, and the effect of their sub lethal exposure to brevetoxin.
Echocardiographic Evaluation of the Right Atrial Area Index in Dogs with Pulmonary Hypertension.
Vezzosi, T; Domenech, O; Iacona, M; Marchesotti, F; Zini, E; Venco, L; Tognetti, R
2018-01-01
Right atrial area (RAA) is a prognostic factor in human patients with pulmonary arterial hypertension (PAH). Reference intervals for RAA have been described in healthy dogs. To evaluate RAA indexed to the body surface area in dogs with PAH as an indicator of right atrial size, PAH severity and right-sided congestive heart failure (R-CHF). A total of 119 client-owned dogs, 48 dogs with PAH and 71 control dogs. Prospective observational study. Pulmonary arterial hypertension was classified according to the tricuspid regurgitation pressure gradient (TRPG) as mild (36-50 mmHg), moderate (51-75 mmHg), or severe (>75 mmHg). The RAA index was calculated as the RAA divided by body surface area. The RAA index was higher in dogs with moderate PAH (13.3 cm 2 /m 2 ; range, 3.4-24.7 cm 2 /m 2 ) and severe PAH (12.1 cm 2 /m 2 ; range, 5.4-21.8 cm 2 /m 2 ) than in those with mild PAH (6.7 cm 2 /m 2 ; range, 4.8-10.7 cm 2 /m 2 ) or in controls (7.3 cm 2 /m 2 ; range, 4.2-10.2 cm 2 /m 2 ; P < 0.001). The RAA index was higher (P < 0.0001) in dogs with R-CHF (17.5 cm 2 /m 2 ; range, 12.7-24.7 cm 2 /m 2 ) compared to those without R-CHF (7.6 cm 2 /m 2 ; range, 4.4-19.4 cm 2 /m 2 ). The most accurate cutoff value of the RAA index to identify R-CHF was >12.3 cm 2 /m 2 (sensitivity, 100%; specificity, 89.5%). In dogs with PAH, severity of tricuspid regurgitation (TR) was the only independent predictor of RAA index based on multivariate analysis (P < 0.02). The RAA index can be used to evaluate right atrial size in dogs and may be more effective than TRPG in predicting R-CHF in dogs with PAH. The severity of TR is the main determinant of the RAA index in dogs with PAH. Copyright © 2018 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.
Peters, Johanna; Taute, Wolfgang; Bartscher, Kathrin; Döscher, Claas; Höft, Michael; Knöchel, Reinhard; Breitkreutz, Jörg
2017-04-08
Microwave sensor systems using resonance technology at a single resonance in the range of 2-3 GHz have been shown to be a rapid and reliable tool for moisture determination in solid materials including pharmaceutical granules. So far, their application is limited to lower moisture ranges or limitations above certain moisture contents had to be accepted. Aim of the present study was to develop a novel multi-resonance sensor system in order to expand the measurement range. Therefore, a novel sensor using additional resonances over a wide frequency band was designed and used to investigate inherent limitations of first generation sensor systems and material-related limits. Using granule samples with different moisture contents, an experimental protocol for calibration and validation of the method was established. Pursuant to this protocol, a multiple linear regression (MLR) prediction model built by correlating microwave moisture values to the moisture determined by Karl Fischer titration was chosen and rated using conventional criteria such as coefficient of determination (R 2 ) and root mean square error of calibration (RMSEC). Using different operators, different analysis dates and different ambient conditions the method was fully validated following the guidance of ICH Q2(R1). The study clearly showed explanations for measurement uncertainties of first generation sensor systems which confirmed the approach to overcome these by using additional resonances. The established prediction model could be validated in the range of 7.6-19.6%, demonstrating its fit for its future purpose, the moisture content determination during wet granulations. Copyright © 2017 Elsevier B.V. All rights reserved.
Weiss, Tobias; Pesch, Beate; Lotz, Anne; Gutwinski, Eleonore; Van Gelder, Rainer; Punkenburg, Ewald; Kendzia, Benjamin; Gawrych, Katarzyna; Lehnert, Martin; Heinze, Evelyn; Hartwig, Andrea; Käfferlein, Heiko U; Hahn, Jens-Uwe; Brüning, Thomas
2013-03-01
The objective of this analysis was to investigate levels and determinants of exposure to airborne and urinary chromium (Cr, CrU) and nickel (Ni, NiU) among 241 welders. Respirable and inhalable welding fume was collected during a shift, and the metal content was determined using inductively coupled plasma mass spectrometry. In post-shift urine, CrU and NiU were measured by means of graphite furnace atom absorption spectrometry, with resulting concentrations varying across a wide range. Due to a large fraction below the limits of quantitation we applied multiple imputations to the log-transformed exposure variables for the analysis of the data. Respirable Cr and Ni were about half of the concentrations of inhalable Cr and Ni, respectively. CrU and NiU were determined with medians of 1.2 μg/L (interquartile range <1.00; 3.61) and 2.9 μg/L (interquartile range <1.50; 5.97). Furthermore, Cr and Ni correlated in respirable welding fume (r=0.79, 95% CI 0.74-0.85) and urine (r=0.55, 95% CI 0.44-0.65). Regression models identified exposure-modulating variables in form of multiplicative factors and revealed slightly better model fits for Cr (R(2) respirable Cr 48%, CrU 55%) than for Ni (R(2) respirable Ni 42%, NiU 38%). The air concentrations were mainly predicted by the metal content in electrodes or base material in addition to the welding technique. Respirable Cr and Ni were good predictors for CrU and NiU, respectively. Exposure was higher when welding was performed in confined spaces or with inefficient ventilation, and lower in urine when respirators were used. In conclusion, statistical modelling allowed the evaluation of determinants of internal and external exposure to Cr and Ni in welders. Welding parameters were stronger predictors than workplace conditions. Airborne exposure was lowest inside respirators with supply of purified air. Copyright © 2012 Elsevier GmbH. All rights reserved.
Accumulation and hazard assessment of mercury to waterbirds at Lake Chapala, Mexico.
Torres, Zaria; Mora, Miguel A; Taylor, Robert J; Alvarez-Bernal, Dioselina; Buelna, Hector R; Hyodo, Ayumi
2014-06-03
Lake Chapala is the largest tropical lake in Mexico. The objectives of this study were to determine bioaccumulation of Hg in fish and to evaluate the potential impacts of Hg in the diet of aquatic birds, particularly the American white pelican (AWPE), in Lake Chapala. Hg concentrations in three fish species ranged from 0.021 to 0.568 μg/g wet weight. Mercury in fish was positively and significantly correlated with total fish length (R2=0.44, P<0.05). The δ15N values in fish were significantly correlated with Hg concentrations in Chapala and the San Antonio Reservoir (R2=0.69, P<0.001 and R2=0.40, P<0.001, respectively). However, Hg concentrations in bird feathers were not significantly different between years, among locations, or among species. Hg concentrations in fish from Lake Chapala were within values reported in many parts of the world. The Hg (mean range of 2.75 to 4.54 μg/g dw) and δD (mean range of -62‰ to -11‰) values in bird feathers suggested a wide pattern of exposure for highly migratory AWPE and egrets, although birds with lower δD values in feathers appeared to have greater concentrations of Hg than those with higher δD values. Contaminant exposure in aquatic birds in Chapala during the breeding season should be monitored next to better determine the potential effects of Hg on resident aquatic birds.
Araujo Júnior, Edward; Martins, Wellington P; Pires, Claudio Rodrigues; Moron, Antonio Fernandes; Zanforlin Filho, Sebastião Marques
2014-08-01
To determine reference range of fetal nasal bone length (NBL) during the second trimester of pregnancy in a Brazilian population. This was a retrospective cross-sectional study with 2681 normal singleton pregnancies between 18 and 24 weeks of gestation. The NBL was obtained in the mid-sagittal plane of the fetal face profile using the following landmarks: nasal bone, overlying skin and the tip of the nose. The NBL was measured by placing the calipers in the out-to-out position. To assess the correlation between NBL and gestational age (GA), polynomial equations were calculated, with adjustments by coefficient of determination (R(2)). The mean of NBL ranged from 5.72 ± 0.87 mm at 18-18 + 6 weeks to 7.45 ± 1.23 mm at 24-24+6 weeks of pregnancy. We observed a good correlation between NBL and GA, best represented by a linear equation: NBL = 0.080+0.276*GA (R(2 )= 0.16). We established a reference range of fetal NBL in the second trimester of pregnancy in a Brazilian population.
Yu, Li-ping; Wang, Xiao-ke; Luo, Jia-bo
2011-04-01
To establish the method for determination of ephedrine hydrochloride, pseudoephedrine hydrochloride and methylephedrine hydrochloride in maxingshigan decoction by capillary electrophoresis. The separation was performed on a fused silica capillary of 60 cm x 55 microcrpm ID (52 cm of effective length). 60 mmol/L NaB4O7 + 10% (V/V) CH3OH (pH 9.0) was selected as the running buffer. The separation voltage was 12 kV. The samples was injected by gravity (10 s, 15 cm). The detection wavelength was 210 nm and berberine hydrochloride was the internal standard. The linear range of determination for ephedrine hydrochloride, pseudoephedrine hydrochloride and methylephedrine hydrochloride were 20.0-160.0 microg/mL (r = 0.9999), 7.5-60.0 microg/mL (r = 0.9991) and 2.0-10.0 microg/mL (r = 0.9993). The average recoveries were 98.0%, 97.0% and 97.8%, the precisions of the method were 2.31%, 2.21% and 2.00% (n=6), respectively. The method is convenient, rapid and accurate for the quality control of maxingshigan decoction.
Chen, Defu; Ren, Jie; Wang, Ying; Zhao, Hongyou; Li, Buhong; Gu, Ying
2016-03-01
Laser Doppler imaging (LDI) and laser speckle imaging (LSI) are two major optical techniques aiming at non-invasively imaging the skin blood perfusion. However, the relationship between perfusion values determined by LDI and LSI has not been fully explored. 8 healthy volunteers and 13 PWS patients were recruited. The perfusions in normal skin on the forearm of 8 healthy volunteers were simultaneously measured by both LDI and LSI during post-occlusive reactive hyperemia (PORH). Furthermore, the perfusions of port wine stains (PWS) lesions and contralateral normal skin of 10 PWS patients were also determined. In addition, the perfusions for PWS lesions from 3 PWS patients were successively monitored at 0, 10 and 20min during vascular-targeted photodynamic therapy (V-PDT). The average perfusion values determined by LSI were compared with those of LDI for each subject. In the normal skin during PORH, power function provided better fits of perfusion values than linear function: powers for individual subjects go from 1.312 to 1.942 (R(2)=0.8967-0.9951). There was a linear relationship between perfusion values determined by LDI and LSI in PWS and contralateral normal skin (R(2)=0.7308-0.9623), and in PWS during V-PDT (R(2)=0.8037-0.9968). The perfusion values determined by LDI and LSI correlate closely in normal skin and PWS over a broad range of skin perfusion. However, it still suggests that perfusion range and characteristics of the measured skin should be carefully considered if LDI and LSI measures are compared. Copyright © 2015 Elsevier B.V. All rights reserved.
Microwave measurement and modeling of the dielectric properties of vegetation
NASA Astrophysics Data System (ADS)
Shrestha, Bijay Lal
Some of the important applications of microwaves in the industrial, scientific and medical sectors include processing and treatment of various materials, and determining their physical properties. The dielectric properties of the materials of interest are paramount irrespective of the applications, hence, a wide range of materials covering food products, building materials, ores and fuels, and biological materials have been investigated for their dielectric properties. However, very few studies have been conducted towards the measurement of dielectric properties of green vegetations, including commercially important plant crops such as alfalfa. Because of its high nutritional value, there is a huge demand for this plant and its processed products in national and international markets, and an investigation into the possibility of applying microwaves to improve both the net yield and quality of the crop can be beneficial. Therefore, a dielectric measurement system based upon the probe reflection technique has been set up to measure dielectric properties of green plants over a frequency range from 300 MHz to 18 GHz, moisture contents from 12%, wet basis to 79%, wet basis, and temperatures from -15°C to 30°C. Dielectric properties of chopped alfalfa were measured with this system over frequency range of 300 MHz to 18 GHz, moisture content from 11.5%, wet basis, to 73%, wet basis, and density over the range from 139 kg m-3 to 716 kg m-3 at 23°C. The system accuracy was found to be +/-6% and +/-10% in measuring the dielectric constant and loss factor respectively. Empirical, semi empirical and theoretical models that require only moisture content and operating frequency were determined to represent the dielectric properties of both leaves and stems of alfalfa at 22°C. The empirical models fitted the measured dielectric data extremely well. The root mean square error (RMSE) and the coefficient of determination (r2) for dielectric constant and loss factor of leaves were 0.89 and 0.99, and 0.52 and 0.99 respectively. The RMSE and r2 values for dielectric constant and loss factor of stems were 0.89 and 0.99, and 0.77 and 0.99 respectively. Among semi empirical or theoretical models, Power law model showed better performance (RMSE = 1.78, r2 = 0.96) in modeling dielectric constant of leaves, and Debye-ColeCole model was more appropriate (RMSE = 1.23, r2 = 0.95) for the loss factor. For stems, the Debye-ColeCole models (developed on an assumption that they do not shrink as they dry) were found to be the best models to calculate the dielectric constant with RMSE 0.53 and r2 = 0.99, and dielectric loss factor with RMSE = 065 and r2 = 0.95. (Abstract shortened by UMI.)
Synthesis, crystal structure and optical properties of BiMgVO 5
NASA Astrophysics Data System (ADS)
Benmokhtar, S.; El Jazouli, A.; Chaminade, J. P.; Gravereau, P.; Guillen, F.; de Waal, D.
2004-11-01
The new vanadate BiMgVO 5 has been prepared and its structure has been determined by single crystal X-ray diffraction: space group P21/n, a=7.542(6) Å, b=11.615(5) Å, c=5.305(3) Å, β=107.38(5)°, wR2=0.0447, R=0.0255. The structure consists of [Mg 2O 10] and [Bi 2O 10] dimers sharing their corners with [VO 4] tetrahedra. The ranges of bond lengths are 2.129-2.814 Å for Bi-O; 2.035-2.167 Å for Mg-O and 1.684-1.745 Å for V-O. V-O bond lengths determined from Raman band wavenumbers are between 1.679 and 1.747 Å. An emission band overlapping the entire visible region with a maximum around 650 nm is observed.
NASA Astrophysics Data System (ADS)
Firth, A. E.; Somerville, R. S.; McMahon, R. G.; Lahav, O.; Ellis, R. S.; Sabbey, C. N.; McCarthy, P. J.; Chen, H.-W.; Marzke, R. O.; Wilson, J.; Abraham, R. G.; Beckett, M. G.; Carlberg, R. G.; Lewis, J. R.; Mackay, C. D.; Murphy, D. C.; Oemler, A. E.; Persson, S. E.
2002-05-01
The Las Campanas Infrared (LCIR) Survey, using the Cambridge Infra-Red Survey Instrument (CIRSI), reaches H ~21 over nearly 1deg2 . In this paper we present results from 744arcmin2 centred on the Hubble Deep Field South for which UBVRI optical data are publicly available. Making conservative magnitude cuts to ensure spatial uniformity, we detect 3177 galaxies to H =20.0 in 744arcmin2 and a further 842 to H =20.5 in a deeper subregion of 407arcmin2 . We compare the observed optical-infrared (IR) colour distributions with the predictions of semi-analytic hierarchical models and find reasonable agreement. We also determine photometric redshifts, finding a median redshift of ~0.55. We compare the redshift distributions N (z ) of E, Sbc, Scd and Im spectral types with models, showing that the observations are inconsistent with simple passive-evolution models while semi-analytic models provide a reasonable fit to the total N (z ) but underestimate the number of z ~1 red spectral types relative to bluer spectral types. We also present N (z ) for samples of extremely red objects (EROs) defined by optical-IR colours. We find that EROs with R -H >4 and H <20.5 have a median redshift z m ~1 while redder colour cuts have slightly higher z m . In the magnitude range 19
Hoch, Matthew C.; Farwell, Kelley E.; Gaven, Stacey L.; Weinhandl, Joshua T.
2015-01-01
Context People with chronic ankle instability (CAI) exhibit less weight-bearing dorsiflexion range of motion (ROM) and less knee flexion during landing than people with stable ankles. Examining the relationship between dorsiflexion ROM and landing biomechanics may identify a modifiable factor associated with altered kinematics and kinetics during landing tasks. Objective To examine the relationship between weight-bearing dorsiflexion ROM and single-legged landing biomechanics in persons with CAI. Design Cross-sectional study. Setting Laboratory. Patients or Other Participants Fifteen physically active persons with CAI (5 men, 10 women; age = 21.9 ± 2.1 years, height = 168.7 ± 9.0 cm, mass = 69.4 ± 13.3 kg) participated. Intervention(s) Participants performed dorsiflexion ROM and single-legged landings from a 40-cm height. Sagittal-plane kinematics of the lower extremity and ground reaction forces (GRFs) were captured during landing. Main Outcome Measure(s) Static dorsiflexion was measured using the weight-bearing–lunge test. Kinematics of the ankle, knee, and hip were observed at initial contact, maximum angle, and sagittal displacement. Sagittal displacements of the ankle, knee, and hip were summed to examine overall sagittal displacement. Kinetic variables were maximum posterior and vertical GRFs normalized to body weight. We used Pearson product moment correlations to evaluate the relationships between dorsiflexion ROM and landing biomechanics. Correlations (r) were interpreted as weak (0.00–0.40), moderate (0.41–0.69), or strong (0.70–1.00). The coefficient of determination (r2) was used to determine the amount of explained variance among variables. Results Static dorsiflexion ROM was moderately correlated with maximum dorsiflexion (r = 0.49, r2 = 0.24), ankle displacement (r = 0.47, r2 = 0.22), and total displacement (r = 0.67, r2 = 0.45) during landing. Dorsiflexion ROM measured statically and during landing demonstrated moderate to strong correlations with maximum knee (r = 0.69–0.74, r2 = 0.47–0.55) and hip (r = 0.50–0.64, r2 = 0.25–0.40) flexion, hip (r = 0.53–0.55, r2 = 0.28–0.30) and knee (r = 0.53–0.70, r2 = 0.28–0.49) displacement, and vertical GRF (−0.47– −0.50, r2 = 0.22–0.25). Conclusions Dorsiflexion ROM was moderately to strongly related to sagittal-plane kinematics and maximum vertical GRF during single-legged landing in persons with CAI. Persons with less dorsiflexion ROM demonstrated a more erect landing posture and greater GRF. PMID:26067428
Hitchcock, Gary L.; Kirkpatrick, Gary; Minnett, Peter; Palubok, Valeriy
2013-01-01
Oxygen-based productivity and respiration rates were determined in West Florida coastal waters to evaluate the proportion of community respiration demands met by autotrophic production within a harmful algal bloom dominated by Karenia brevis. The field program was adaptive in that sampling during the 2006 bloom occurred where surveys by the Florida Wildlife Research Institute indicated locations with high cell abundances. Net community production (NCP) rates from light-dark bottle incubations during the bloom ranged from 10 to 42 µmole O2 L−1 day−1 with highest rates in bloom waters where abundances exceeded 105 cells L−1. Community dark respiration (R) rates in dark bottles ranged from <10 to 70 µmole O2 L−1 day−1 over 24 h. Gross primary production derived from the sum of NCP and R varied from ca. 20 to 120 µmole O2 L−1 day−1. The proportion of GPP attributed to NCP varied with the magnitude of R during day and night periods. Most surface communities exhibited net autotrophic production (NCP > R) over 24 h, although heterotrophy (NCP < R) characterized the densest sample where K. brevis cell densities exceed 106 cells L−1. PMID:24179460
Hitchcock, Gary L; Kirkpatrick, Gary; Minnett, Peter; Palubok, Valeriy
2010-05-01
Oxygen-based productivity and respiration rates were determined in West Florida coastal waters to evaluate the proportion of community respiration demands met by autotrophic production within a harmful algal bloom dominated by Karenia brevis . The field program was adaptive in that sampling during the 2006 bloom occurred where surveys by the Florida Wildlife Research Institute indicated locations with high cell abundances. Net community production (NCP) rates from light-dark bottle incubations during the bloom ranged from 10 to 42 µmole O 2 L -1 day -1 with highest rates in bloom waters where abundances exceeded 10 5 cells L -1 . Community dark respiration ( R ) rates in dark bottles ranged from <10 to 70 µmole O 2 L -1 day -1 over 24 h. Gross primary production derived from the sum of NCP and R varied from ca. 20 to 120 µmole O 2 L -1 day -1 . The proportion of GPP attributed to NCP varied with the magnitude of R during day and night periods. Most surface communities exhibited net autotrophic production (NCP > R ) over 24 h, although heterotrophy (NCP < R ) characterized the densest sample where K. brevis cell densities exceed 10 6 cells L -1 .
Wankhede, Dnyaneshwar Shamrao
2012-06-01
Refractive indices (n) have been experimentally determined for the binary liquid-liquid mixtures of Propylene carbonate (PC) (1) with benzene, ethylbenzene, o-xylene and p-xylene (2) at 298.15, 303.15 and 308.15 K over the entire mole fraction range. The experimental values of n are utilised to calculate deviation in refractive index (Δn), molar refraction (R) and deviation in molar refraction (ΔR). A comparative study of Arago-Biot (A-B), Newton (NW), Eyring and John (E-J) equations for determining refractive index of a liquid has been carried out to test their validity for all the binary mixtures over the entire composition range at 298.15 K. Comparison of various mixing relations is represented in terms of average deviation (AVD). The Δn and ΔR values have been fitted to Redlich-Kister equation at 298.15 K and standard deviations have been calculated. The results are discussed in terms of intermolecular interactions present amongst the components.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bayrak, Yusuf, E-mail: ybayrak@agri.edu.tr; Türker, Tuğba, E-mail: tturker@ktu.edu.tr
The aim of this study; were determined of the earthquake hazard using the exponential distribution method for different seismic sources of the Ağrı and vicinity. A homogeneous earthquake catalog has been examined for 1900-2015 (the instrumental period) with 456 earthquake data for Ağrı and vicinity. Catalog; Bogazici University Kandilli Observatory and Earthquake Research Institute (Burke), National Earthquake Monitoring Center (NEMC), TUBITAK, TURKNET the International Seismological Center (ISC), Seismological Research Institute (IRIS) has been created using different catalogs like. Ağrı and vicinity are divided into 7 different seismic source regions with epicenter distribution of formed earthquakes in the instrumental period, focalmore » mechanism solutions, and existing tectonic structures. In the study, the average magnitude value are calculated according to the specified magnitude ranges for 7 different seismic source region. According to the estimated calculations for 7 different seismic source regions, the biggest difference corresponding with the classes of determined magnitudes between observed and expected cumulative probabilities are determined. The recurrence period and earthquake occurrence number per year are estimated of occurring earthquakes in the Ağrı and vicinity. As a result, 7 different seismic source regions are determined occurrence probabilities of an earthquake 3.2 magnitude, Region 1 was greater than 6.7 magnitude, Region 2 was greater than than 4.7 magnitude, Region 3 was greater than 5.2 magnitude, Region 4 was greater than 6.2 magnitude, Region 5 was greater than 5.7 magnitude, Region 6 was greater than 7.2 magnitude, Region 7 was greater than 6.2 magnitude. The highest observed magnitude 7 different seismic source regions of Ağrı and vicinity are estimated 7 magnitude in Region 6. Region 6 are determined according to determining magnitudes, occurrence years of earthquakes in the future years, respectively, 7.2 magnitude was in 158 years, 6.7 magnitude was in 70 years, 6.2 magnitude was in 31 years, 5.7 magnitude was in 13 years, 5.2 magnitude was in 6 years.« less
NASA Astrophysics Data System (ADS)
Bayrak, Yusuf; Türker, Tuǧba
2016-04-01
The aim of this study; were determined of the earthquake hazard using the exponential distribution method for different seismic sources of the Aǧrı and vicinity. A homogeneous earthquake catalog has been examined for 1900-2015 (the instrumental period) with 456 earthquake data for Aǧrı and vicinity. Catalog; Bogazici University Kandilli Observatory and Earthquake Research Institute (Burke), National Earthquake Monitoring Center (NEMC), TUBITAK, TURKNET the International Seismological Center (ISC), Seismological Research Institute (IRIS) has been created using different catalogs like. Aǧrı and vicinity are divided into 7 different seismic source regions with epicenter distribution of formed earthquakes in the instrumental period, focal mechanism solutions, and existing tectonic structures. In the study, the average magnitude value are calculated according to the specified magnitude ranges for 7 different seismic source region. According to the estimated calculations for 7 different seismic source regions, the biggest difference corresponding with the classes of determined magnitudes between observed and expected cumulative probabilities are determined. The recurrence period and earthquake occurrence number per year are estimated of occurring earthquakes in the Aǧrı and vicinity. As a result, 7 different seismic source regions are determined occurrence probabilities of an earthquake 3.2 magnitude, Region 1 was greater than 6.7 magnitude, Region 2 was greater than than 4.7 magnitude, Region 3 was greater than 5.2 magnitude, Region 4 was greater than 6.2 magnitude, Region 5 was greater than 5.7 magnitude, Region 6 was greater than 7.2 magnitude, Region 7 was greater than 6.2 magnitude. The highest observed magnitude 7 different seismic source regions of Aǧrı and vicinity are estimated 7 magnitude in Region 6. Region 6 are determined according to determining magnitudes, occurrence years of earthquakes in the future years, respectively, 7.2 magnitude was in 158 years, 6.7 magnitude was in 70 years, 6.2 magnitude was in 31 years, 5.7 magnitude was in 13 years, 5.2 magnitude was in 6 years.
Skipworth, R J E; Deans, D A C; Tan, B H L; Sangster, K; Paterson-Brown, S; Brown, D A; Hunter, M; Breit, S N; Ross, J A; Fearon, K C H
2010-01-01
Background: Macrophage inhibitory cytokine-1(MIC-1) is a potential modulator of systemic inflammation and nutritional depletion, both of which are adverse prognostic factors in oesophago-gastric cancer (OGC). Methods: Plasma MIC-1, systemic inflammation (defined as plasma C-reactive protein (CRP) of ⩾10 mg l–1 or modified Glasgow prognostic score (mGPS) of ⩾1), and nutritional status were assessed in newly diagnosed OGC patients (n=293). Healthy volunteers (n=35) served as controls. Results: MIC-1 was elevated in patients (median=1371 pg ml–1; range 141–39 053) when compared with controls (median=377 pg ml–1; range 141–3786; P<0.001). Patients with gastric tumours (median=1592 pg ml–1; range 141–12 643) showed higher MIC-1 concentrations than patients with junctional (median=1337 pg ml–1; range 383–39 053) and oesophageal tumours (median=1180 pg ml–1; range 258–31 184; P=0.015). Patients showed a median weight loss of 6.4% (range 0.0–33.4%), and 42% of patients had an mGPS of ⩾1 or plasma CRP of ⩾10 mg l–1 (median=9 mg l–1; range 1–200). MIC-1 correlated positively with disease stage (r2=0.217; P<0.001), age (r2=0.332; P<0.001), CRP (r2=0.314; P<0.001), and mGPS (r2=0.336; P<0.001), and negatively with Karnofsky Performance Score (r2=−0.269; P<0.001). However, although MIC-1 correlated weakly with dietary intake (r2=0.157; P=0.031), it did not correlate with weight loss, BMI, or anthropometry. Patients with MIC-1 levels in the upper quartile showed reduced survival (median=204 days; 95% CI 157–251) when compared with patients with MIC-1 levels in the lower three quartiles (median=316 days; 95% CI 259–373; P=0.036), but MIC-1 was not an independent prognostic indicator. Conclusions: There is no independent link between plasma MIC-1 levels and depleted nutritional status or survival in OGC. PMID:20104227
Martínez, J; Martínez de Sarasa Buchaca, M; de la Cruz-Martínez, F; Alonso-Moreno, C; Sánchez-Barba, L F; Fernandez-Baeza, J; Rodríguez, A M; Rodríguez-Diéguez, A; Castro-Osma, J A; Otero, A; Lara-Sánchez, A
2018-05-22
A series of alkyl aluminium complexes based on heteroscorpionate ligands were designed as catalysts for the ring-opening polymerisation of cyclic esters and ring-opening copolymerisation of epoxides and anhydrides. Treatment of AlX3 (X = Me, Et) with ligands bpzbeH [bpzbe = 1,1-bis(3,5-dimethylpyrazol-1-yl)-3,3-dimethyl-2-butoxide], bpzteH [bpzte = 2,2-bis(3,5-dimethylpyrazol-1-yl)-1-para-tolylethoxide], and (R,R)-bpzmmH [(R,R)-bpzmm = (1R)-1-{(1R)-6,6-dimethyl-bicyclo[3.1.1]-2-hepten-2-yl}-2,2-bis(3,5-dimethylpyrazol-1-yl)ethoxide] for 2 hours at 0 °C afforded the mononuclear dialkyl aluminium complexes [AlMe2{κ2-bpzbe}] (1), [AlEt2{κ2-bpzbe}] (2), [AlMe2{κ2-(R,R)-bpzmm}] (3) and [AlEt2{κ2-(R,R)-bpzmm}] (4), and the dinuclear dialkyl complexes [AlMe2{κ2-bpzte}]2 (5) and [AlEt2{κ2-bpzte}]2 (6). The molecular structures of the new complexes were determined by spectroscopic methods and confirmed by X-ray crystallography. The alkyl-containing aluminium complexes can act as highly efficient single-component initiators for the ring-opening polymerisation of ε-caprolactone and l-lactide and for the ring-opening copolymerisation of cyclohexene oxide and phthalic anhydride to give a range of biodegradable polyesters.
NASA Astrophysics Data System (ADS)
Jones, G. T.; Jones, R. W. L.; Kennedy, B. W.; Klein, H.; Morrison, D. R. O.; Wachsmuth, H.; Miller, D. B.; Mobayyen, M. M.; Wainstein, S.; Aderholz, M.; Hantke, D.; Katz, U. F.; Kern, J.; Schmitz, N.; Wittek, W.; Borner, H. P.; Myatt, G.; Cooper-Sarkar, A. M.; Guy, J.; Venus, W.; Bullock, F. W.; Burke, S.
1994-12-01
Based on a QCD analysis of the parton momentum distributions in the proton, the ratio r v = d v / u v of the d and u valence quark distributions is determined as function of x in the range 0.01< x<0.7. The analysis uses data from neutrino and antineutrino charged current interactions on hydrogen and deuterium, obtained with BEBC in the (anti)neutrino wideband beam of the CERN SPS. Since v mainly depends on the deuterium/hydrogen ratios of the normalised x-y-Q 2-distributions many systematic effects cancel. It is found that r v decreases with increasing x, and drops below the naive SU(6) expectation of 0.5 for x≳0.3. An extrapolation of r v to x=1 is consistent with the hypothesis r v (1)=0.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Uresk, D.W.; Gilbert, R.O.; Rickard, W.H.
Big sagebrush (Artemisia tridentata) was subjected to a double sampling procedure to obtain reliable phytomass estimates for leaves, flowering stalks, live wood, dead wood, various combinations of the preceeding, and total phytomass. Coefficients of determination (R/sup 2/) between the independent variable and various phytomass categories ranged from 0.45 to 0.93. Total phytomass was approximately 69 +- 16 (+- S.E.) g/m/sup 2/. Reductions in the variance of the phytomass estimates ranged from 33 percent to 80 percent using double sampling assuming optimum allocation. (auth)
Lower-body determinants of running economy in male and female distance runners.
Barnes, Kyle R; Mcguigan, Michael R; Kilding, Andrew E
2014-05-01
A variety of training approaches have been shown to improve running economy in well-trained athletes. However, there is a paucity of data exploring lower-body determinants that may affect running economy and account for differences that may exist between genders. Sixty-three male and female distance runners were assessed in the laboratory for a range of metabolic, biomechanical, and neuromuscular measures potentially related to running economy (ml·kg(-1)·min(-1)) at a range of running speeds. At all common test velocities, women were more economical than men (effect size [ES] = 0.40); however, when compared in terms of relative intensity, men had better running economy (ES = 2.41). Leg stiffness (r = -0.80) and moment arm length (r = 0.90) were large-extremely largely correlated with running economy and each other (r = -0.82). Correlations between running economy and kinetic measures (peak force, peak power, and time to peak force) for both genders were unclear. The relationship in stride rate (r = -0.27 to -0.31) was in the opposite direction to that of stride length (r = 0.32-0.49), and the relationship in contact time (r = -0.21 to -0.54) was opposite of that of flight time (r = 0.06-0.74). Although both leg stiffness and moment arm length are highly related to running economy, it seems that no single lower-body measure can completely explain differences in running economy between individuals or genders. Running economy is therefore likely determined from the sum of influences from multiple lower-body attributes.
1955-05-01
6.2.1 Seismic Height of Burst Determination 6l 6.2.2 Long Range Yield Determination 6l 6.2.3 Lead Sulphide Cells 6l | • APPENDIX A SURVEY...located at M 96 in the vicinity of Array 3* The original metro station was moved to vicinity Camp Mercury Sewage Disposal Plant for Shots 9 and 10. The...JWiRE COMMUNICATION =r=^^l .QBAWIELS ., I foi* 50—ftfejP - -70 CAMP DESERT MICROPHONE 40- 15" (CAMP --’ MERCURY -60 MICROPHONE ARRAY NO I
Tees, D F; Waugh, R E; Hammer, D A
2001-01-01
A microcantilever technique was used to apply force to receptor-ligand molecules involved in leukocyte rolling on blood vessel walls. E-selectin was adsorbed onto 3-microm-diameter, 4-mm-long glass fibers, and the selectin ligand, sialyl Lewis(x), was coupled to latex microspheres. After binding, the microsphere and bound fiber were retracted using a computerized loading protocol that combines hydrodynamic and Hookean forces on the fiber to produce a range of force loading rates (force/time), r(f). From the distribution of forces at failure, the average force was determined and plotted as a function of ln r(f). The slope and intercept of the plot yield the unstressed reverse reaction rate, k(r)(o), and a parameter that describes the force dependence of reverse reaction rates, r(o). The ligand was titrated so adhesion occurred in approximately 30% of tests, implying that >80% of adhesive events involve single bonds. Monte Carlo simulations show that this level of multiple bonding has little effect on parameter estimation. The estimates are r(o) = 0.048 and 0.016 nm and k(r)(o) = 0.72 and 2.2 s(-1) for loading rates in the ranges 200-1000 and 1000-5000 pN s(-1), respectively. Levenberg-Marquardt fitting across all values of r(f) gives r(o) = 0.034 nm and k(r)(o) = 0.82 s(-1). The values of these parameters are in the range required for rolling, as suggested by adhesive dynamics simulations. PMID:11159435
Xia, Ben-Li; Cong, Ji-Xin; Li, Xia; Wang, Xuan-Jun
2011-06-01
The rocket kerosene quality properties such as density, distillation range, viscosity and iodine value were successfully measured based on their near-infrared spectrum (NIRS) and chemometrics. In the present paper, more than 70 rocket kerosene samples were determined by near infrared spectrum, the models were built using the partial least squares method within the appropriate wavelength range. The correlation coefficients (R2) of every rocket kerosene's quality properties ranged from 0.862 to 0.999. Ten unknown samples were determined with the model, and the result showed that the prediction accuracy of near infrared spectrum method accords with standard analysis requirements. The new method is well suitable for replacing the traditional standard method to rapidly determine the properties of the rocket kerosene.
Digitised evaluation of speech intelligibility using vowels in maxillectomy patients.
Sumita, Y I; Hattori, M; Murase, M; Elbashti, M E; Taniguchi, H
2018-03-01
Among the functional disabilities that patients face following maxillectomy, speech impairment is a major factor influencing quality of life. Proper rehabilitation of speech, which may include prosthodontic and surgical treatments and speech therapy, requires accurate evaluation of speech intelligibility (SI). A simple, less time-consuming yet accurate evaluation is desirable both for maxillectomy patients and the various clinicians providing maxillofacial treatment. This study sought to determine the utility of digital acoustic analysis of vowels for the prediction of SI in maxillectomy patients, based on a comprehensive understanding of speech production in the vocal tract of maxillectomy patients and its perception. Speech samples were collected from 33 male maxillectomy patients (mean age 57.4 years) in two conditions, without and with a maxillofacial prosthesis, and formant data for the vowels /a/,/e/,/i/,/o/, and /u/ were calculated based on linear predictive coding. The frequency range of formant 2 (F2) was determined by differences between the minimum and maximum frequency. An SI test was also conducted to reveal the relationship between SI score and F2 range. Statistical analyses were applied. F2 range and SI score were significantly different between the two conditions without and with a prosthesis (both P < .0001). F2 range was significantly correlated with SI score in both the conditions (Spearman's r = .843, P < .0001; r = .832, P < .0001, respectively). These findings indicate that calculating the F2 range from 5 vowels has clinical utility for the prediction of SI after maxillectomy. © 2017 John Wiley & Sons Ltd.
Ahmadkhaniha, Reza; Samadi, Nasrin; Salimi, Mona; Sarkhail, Parisa; Rastkari, Noushin
2012-01-01
A reliable and sensitive headspace solid-phase microextraction gas chromatography-mass spectrometry method for simultaneous determination of different organophosphorus pesticides in dried medicinal plant samples is described. The analytes were extracted by single-walled carbon nanotubes as a new solid-phase microextraction adsorbent. The developed method showed good performance. For diazinon and pirimiphos methyl calibration, curves were linear (r 2 ≥ 0.993) over the concentration ranges from 1.5 to 300 ng g−1, and the limit of detection at signal-to-noise ratio of 3 was 0.3 ng g−1. For parathion and malathion, the linear range and limit of detection were 2.5–300 (r 2 ≥ 0.991) and 0.5 ng g−1, respectively. In addition, a comparative study between the single-walled carbon nanotubes and a commercial polydimethylsiloxane fibre for the determination of target analytes was carried out. Single-walled carbon nanotubes fibre showed higher extraction capacity, better thermal stability (over 350°C), and longer lifespan (over 250 times) than the commercial polydimethylsiloxane fibre. The developed method was successfully applied to determine target organophosphorus pesticides in real samples. PMID:22645439
Kotnik, Petra; Krajnc, Metka Koren; Pahor, Artur; Finšgar, Matjaž; Knez, Željko
2018-02-20
A quantitative analysis of zinc endopeptidases matrix metalloproteinase 9 (MMP9) and matrix metalloproteinase 3 (MMP3) from human blood serum are presented. Both matrix metalloproteinases (MMP) are present in human blood serum and can be used as biomarkers for different diseases. The analysis was performed using LC-MS/MS with a triple quadrupole mass spectrometer, based on two specific peptides of each MMP in comparison with an enzyme-linked immunosorbent assay (ELISA). While the conditions for the LC-MS/MS analysis of MMP9 peptides were previously reported for bronchoalveolar lavage fluid, the analysis of MMP3 peptides was newly quantified for human blood serum herein for the first time. For MMP3, the linear behaviour was determined in the concentration range from 1.0-200.0ng/mL (R 2 =0.997) with an LLOD of 0.5ng/mL. For MMP9, linearity was determined in the concentration range from 6.5-65.0ng/mL (R 2 =0.995) with an LLOD of 2.0ng/mL. Copyright © 2017 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schlickeiser, R.; Lazar, M.; Vukcevic, M., E-mail: rsch@tp4.rub.d, E-mail: mlazar@tp4.ruhr-uni-bochum.d, E-mail: vuk.mira@gmail.co
2010-08-20
The influence of the polarization state and the dissipation range spectral steepening of slab plasma waves on the scattering mean free path of single-charged cosmic-ray particles is investigated in a turbulence model, where the crucial scattering of cosmic-ray particles with small pitch-angle cosines is caused by resonant cyclotron interactions with slab plasma waves. Analytical expressions for the mean free path of protons, antiprotons, negatrons, and positrons are derived for the case of constant frequency-independent magnetic helicity values {sigma} and different values of the dissipation range spectral index k for characteristic interplanetary and interstellar plasma conditions. The positron mean free pathmore » is not affected by the dissipation range spectral index k as these particles can only cyclotron-resonate for rigidity values larger than R {sub 0} = m{sub p}c = 938 MV. Proton and antiproton mean free paths are only slightly affected by the dissipation range spectral index k at small rigidities R < R {sub 0}. The negatron mean free path is severely affected by the dissipation range spectral index k at rigidities smaller than R {sub 0}. At high rigidities R >> R {sub 0}, all particle species approach the same power-law dependence {proportional_to}R {sup 2-s} determined by the inertial range spectral index s = 5/3. The magnetic helicity value {sigma} affects the value of the mean free path. At all rigidities, the ratio of the antiproton to proton mean free paths equals the constant (1 + {sigma})/(1 - {sigma}), which also agrees with the ratio of the negatron to the proton and positron mean free paths at relativistic rigidities. At relativistic rigidities the positron and proton mean free paths agree, as do the negatron and antiproton mean free paths.« less
O'Leary, D D; Lin, D C; Hughson, R L
1999-09-01
The heart rate component of the arterial baroreflex gain (BRG) was determined with auto-regressive moving-average (ARMA) analysis during each of spontaneous (SB) and random breathing (RB) protocols. Ten healthy subjects completed each breathing pattern on two different days in each of two different body positions, supine (SUP) and head-up tilt (HUT). The R-R interval, systolic arterial pressure (SAP) and instantaneous lung volume were recorded continuously. BRG was estimated from the ARMA impulse response relationship of R-R interval to SAP and from the spontaneous sequence method. The results indicated that both the ARMA and spontaneous sequence methods were reproducible (r = 0.76 and r = 0.85, respectively). As expected, BRG was significantly less in the HUT compared to SUP position for both ARMA (mean +/- SEM; 3.5 +/- 0.3 versus 11.2 +/- 1.4 ms mmHg-1; P < 0.01) and spontaneous sequence analysis (10.3 +/- 0.8 versus 31.5 +/- 2.3 ms mmHg-1; P < 0.001). However, no significant difference was found between BRG during RB and SB protocols for either ARMA (7.9 +/- 1.4 versus 6.7 +/- 0.8 ms mmHg-1; P = 0.27) or spontaneous sequence methods (21.8 +/- 2.7 versus 20.0 +/- 2.1 ms mmHg-1; P = 0.24). BRG was correlated during RB and SB protocols (r = 0.80; P < 0.0001). ARMA and spontaneous BRG estimates were correlated (r = 0.79; P < 0.0001), with spontaneous sequence values being consistently larger (P < 0.0001). In conclusion, we have shown that ARMA-derived BRG values are reproducible and that they can be determined during SB conditions, making the ARMA method appropriate for use in a wider range of patients.
Udompaisarn, Somsiri; Arthan, Dumrongkiet; Somana, Jamorn
2017-04-19
An enzymatic method for specific determination of stevioside content was established. Recombinant β-glucosidase BT_3567 (rBT_3567) from Bacteroides thetaiotaomicron HB-13 exhibited selective hydrolysis of stevioside at β-1,2-glycosidic bond to yield rubusoside and glucose. Coupling of this enzyme with glucose oxidase and peroxidase allowed for quantitation of stevioside content in Stevia samples by using a colorimetric-based approach. The series of reactions for stevioside determination can be completed within 1 h at 37 °C. Stevioside determination using the enzymatic assay strongly correlated with results obtained from HPLC quantitation (r 2 = 0.9629, n = 16). The percentages of coefficient variation (CV) of within day (n = 12) and between days (n = 12) assays were lower than 5%, and accuracy ranges were 95-105%. This analysis demonstrates that the enzymatic method developed in this study is specific, easy to perform, accurate, and yields reproducible results.
Pratt, Russell C.; Lyons, Christopher T.; Wasinger, Erik C.; Stack, T. Daniel. P.
2012-01-01
Non-symmetric substitution of salen (1R1,R2) and reduced salen (2R1,R2) CuII-phenoxyl complexes with a combination of -tBu, -SiPr, and -OMe substituents leads to dramatic differences in their redox and spectroscopic properties, providing insight into the influence of the cysteine-modified tyrosine cofactor in the enzyme galactose oxidase (GO). Using a modified Marcus-Hush analysis, the oxidized copper complexes are characterized as Class II mixed-valent due to the electronic differentiation between the two substituted phenolates. Sulfur K-edge X-ray absorption spectroscopy (XAS) assesses the degree of radical delocalization onto the single sulfur atom of non-symmetric [1tBu,SMe]+ at 7%, consistent with other spectroscopic and electrochemical results that suggest preferential oxidation of the -SMe bearing phenolate. Estimates of the thermodynamic free-energy difference between the two localized states (ΔG∘) and reorganizational energies (λR1R2) of [1R1,R2]+ and [2R1,R2]+ leads to accurate predictions of the spectroscopically observed IVCT transition energies. Application of the modified Marcus-Hush analysis to GO using parameters determined for [2R1,R2]+ predicts a νmax of ~ 13600 cm−1, well within the energy range of the broad Vis-NIR band displayed by the enzyme. PMID:22471355
Li, Cunhong; Chen, Anjia; Chen, Xiaofeng; Chen, Xingguo; Hu, Zhide
2005-09-01
A simple method for the simultaneous determination of five bioactive components (rutin, puerarin, daidzein esculin and esculetin) in traditional medicinal preparations by non-aqueous capillary electrophoresis with UV detection has been developed for the first time. A running buffer composed of 15% acetonitrile, 2.5% acetic acid and 90 mM sodium cholate in methanol was found to be the most suitable for this separation. The limits of detection for five analytes were over the range of 0.050-1.216 microg ml(-1). The relative standard deviations (R.S.Ds.) of the migration times and the peak areas of the analytes were in the range of 1.3-2.9% and 2.2-2.7% (intraday), 1.7-1.9% and 2.8-3.6% (interday), respectively. In the tested concentration range, linear relationships (correlation coefficients: 0.9974 for rutin, 0.9976 for puerarin, 0.9981 for daidzein, 0.9972 for esculin and 0.9929 for esculetin) between peak areas and concentrations of the analytes were obtained. This method has been successfully applied to simultaneous determination of the five bioactive components with recoveries over the range of 89.4-107.4%.
Predictive value of clinical scoring and simplified gait analysis for acetabulum fractures.
Braun, Benedikt J; Wrona, Julian; Veith, Nils T; Rollman, Mika; Orth, Marcel; Herath, Steven C; Holstein, Jörg H; Pohlemann, Tim
2016-12-01
Fractures of the acetabulum show a high, long-term complication rate. The aim of the present study was to determine the predictive value of clinical scoring and standardized, simplified gait analysis on the outcome after these fractures. Forty-one patients with acetabular fractures treated between 2008 and 2013 and available, standardized video recorded aftercare were identified from a prospective database. A visual gait score was used to determine the patients walking abilities 6-m postoperatively. Clinical (Merle d'Aubigne and Postel score, visual analogue scale pain, EQ5d) and radiological scoring (Kellgren-Lawrence score, postoperative computed tomography, and Matta classification) were used to perform correlation and multivariate regression analysis. The average patient age was 48 y (range, 15-82 y), six female patients were included in the study. Mean follow-up was 1.6 y (range, 1-2 y). Moderate correlation between the gait score and outcome (versus EQ5d: r s = 0.477; versus Merle d'Aubigne: r s = 0.444; versus Kellgren-Lawrence: r s = -0.533), as well as high correlation between the Merle d'Aubigne score and outcome were seen (versus EQ5d: r s = 0.575; versus Merle d'Aubigne: r s = 0.776; versus Kellgren-Lawrence: r s = -0.419). Using a multivariate regression model, the 6 m gait score (B = -0.299; P < 0.05) and early osteoarthritis development (B = 1.026; P < 0.05) were determined as predictors of final osteoarthritis. A good fit of the regression model was seen (R 2 = 904). Easy and available clinical scoring (gait score/Merle d'Aubigne) can predict short-term radiological and functional outcome after acetabular fractures with sufficient accuracy. Decisions on further treatment and interventions could be based on simplified gait analysis. Copyright © 2016 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Benedito, J.; Cambero, M. I.; Ortuño, C.; Cabeza, M. C.; Ordoñez, J. A.; de la Hoz, L.
2011-03-01
The E-beam irradiation of vacuum-packaged RTE cooked ham was carried out to establish the dose required to achieve the food safety objective (FSO) and to minimize changes in selected sensory attributes. Cooked ham was irradiated with doses ranging 1-4 kGy. After the treatment, the microbial inactivation of Listeria monocytogenes, the shelf-life of the product and some sensory attributes (appearance, odor, and flavor) were determined. The inactivation of L. monocytogenes was satisfactorily described by a first-order kinetics equation ( R2=0.99). The influence of the irradiation dose on appearance, odor, and flavor was modeled through Gompertz ( R2=0.99, for appearance) and Activation/Inactivation ( R2=0.99, for odor and flavor) equations. A model was also developed to determine the shelf-life of irradiated cooked ham depending on the irradiation dose ( R2>0.91). The dose that maximized the scores of the sensory attributes was 0.96 kGy resulting in an acceptable sensory quality for 80 days. It is possible to apply up to 2 kGy to ensure microbial safety, while provoking no significant changes in the above mentioned sensory attributes.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mardirossian, Narbe; Ruiz Pestana, Luis; Womack, James C.
The VV10 and rVV10 nonlocal correlation functionals are consistently implemented and assessed, with the goal of determining if the rVV10 nonlocal correlation functional can replace the VV10 nonlocal correlation functional in the recently developed B97M-V density functional, to give the B97M-rV density functional. Along the way, four density functionals are simultaneously tested: VV10, rVV10, B97M-V, and B97M-rV. An initial assessment is carried out across the S22 data set, and the short-range damping variable, b, is varied for all four density functionals in order to determine the sensitivity of the functionals to the empirical parameter. The results of this test indicatemore » that a value of b = 6 (fortuitously the same as that in B97M-V) is suitable for B97M-rV. The functionals are then compared across an extensive database of interaction energies, and it is demonstrated that B97M-rV either matches or outperforms B97M-V for all of the tests considered. Finally, the optimization of b across the S22 data set is extended to two range-separated hybrid density functionals, ωB97X-V and ωB97M-V, and a value of b = 6.2 is recommended for both ωB97X-rV and ωB97M-rV.« less
Mardirossian, Narbe; Ruiz Pestana, Luis; Womack, James C.; ...
2016-12-06
The VV10 and rVV10 nonlocal correlation functionals are consistently implemented and assessed, with the goal of determining if the rVV10 nonlocal correlation functional can replace the VV10 nonlocal correlation functional in the recently developed B97M-V density functional, to give the B97M-rV density functional. Along the way, four density functionals are simultaneously tested: VV10, rVV10, B97M-V, and B97M-rV. An initial assessment is carried out across the S22 data set, and the short-range damping variable, b, is varied for all four density functionals in order to determine the sensitivity of the functionals to the empirical parameter. The results of this test indicatemore » that a value of b = 6 (fortuitously the same as that in B97M-V) is suitable for B97M-rV. The functionals are then compared across an extensive database of interaction energies, and it is demonstrated that B97M-rV either matches or outperforms B97M-V for all of the tests considered. Finally, the optimization of b across the S22 data set is extended to two range-separated hybrid density functionals, ωB97X-V and ωB97M-V, and a value of b = 6.2 is recommended for both ωB97X-rV and ωB97M-rV.« less
Ångerman, S; Länkimäki, S; Neuvonen, N; Kirves, H; Nurmi, J
2018-05-22
Near-infrared spectroscopy (NIRS) provides a non-invasive measure of cerebral tissue oxygenation. The literature on application of this method in pre-hospital setting is limited. The aims of this study were to determine the feasibility of cerebral NIRS during pre-hospital anaesthesia and to quantify the changes in front lobe regional oxygen saturation (rSO 2 ) during the pre-hospital phase. NIRS monitoring (Nonin SenSmart X-100) of front lobe regional oxygen saturation (rSO2) was initiated before induction of anaesthesia in 31 adult patients and continued until hospital arrival. The median age of the patients was 55 years (IQR [range] 43-63 [20-84]), and 20 (65%) of the patients were male. The indications for pre-hospital anaesthesia were neurological reasons (29%), intoxication (23%), traumatic brain injury (23%) and successful resuscitation from cardiac arrest (16%). The NIRS monitoring was successful in 29 of 31 cases (94%; 95% CI: 78-99). One patient could not be monitored due to poor probe-skin contact, and 1 patient had poor contact with 1 hemisphere. Monitoring was performed for a total of 1335 minutes and was successful in both hemispheres 95% (95% CI: 94-96) of the time. The median lowest rSO 2 was 8% (IQR [range] 2-13 [0-30]) below baseline, and median peak rSO 2 was 7% (IQR [range] 2-11 [0-34]) above the baseline. Changes in rSO 2 without accompanying changes in vital signs were observed. NIRS is feasible during pre-hospital anaesthesia and substantial changes were observed in some patients. It provides data beyond the standard monitoring used in the pre-hospital setting. © 2018 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
NOTE: The effects of paramagnetic contrast agents on metabolite protons in aqueous solution
NASA Astrophysics Data System (ADS)
Murphy, Philip S.; Leach, Martin O.; Rowland, Ian J.
2002-03-01
The longitudinal (R1) and transverse (R2) relaxivities of the clinically used contrast agents Gd(DTPA)2-, Gd(DOTA)- and Gd(DTPA-BMA) have been determined in mixed aqueous metabolite solutions for choline, creatine and N-acetylaspartate. Measurements were performed at 1.5 T using a STEAM sequence on 25 mM metabolite solutions at pH = 7.4 and 22 °C. The data showed that for all the contrast agents and metabolites, R1 ~ R2. The largest range of relaxivity values was found for Gd(DTPA)2-, where R2 = 6.8 +/- 0.3 mM-1 s-1 for choline and 1.5 +/- 0.4 mM-1 s-1 for N-acetylaspartate. Variation in relaxivity values was attributed primarily to differences between the charges of the paramagnetic agent and metabolite. The maximum potential influence of the contrast agents on in vivo metabolite signals was calculated using the measured relaxivities.
Heavy metal tolerance and removal potential in mixed-species biofilm.
Grujić, Sandra; Vasić, Sava; Čomić, Ljiljana; Ostojić, Aleksandar; Radojević, Ivana
2017-08-01
The aim of the study was to examine heavy metal tolerance (Cd 2+ , Zn 2+ , Ni 2+ and Cu 2+ ) of single- and mixed-species biofilms (Rhodotorula mucilaginosa and Escherichia coli) and to determine metal removal efficiency (Cd 2+ , Zn 2+ , Ni 2+ , Cu 2+ , Pb 2+ and Hg 2+ ). Metal tolerance was quantified by crystal violet assay and results were confirmed by fluorescence microscopy. Metal removal efficiency was determined by batch biosorption assay. The tolerance of the mixed-species biofilm was higher than the single-species biofilms. Single- and mixed-species biofilms showed the highest sensitivity in the presence of Cu 2+ (E. coli-MIC 4 mg/ml, R. mucilaginosa-MIC 8 mg/ml, R. mucilaginosa/E. coli-MIC 64 mg/ml), while the highest tolerance was observed in the presence of Zn 2+ (E. coli-MIC 80 mg/ml, R. mucilaginosa-MIC 161 mg/ml, R. mucilaginosa-E. coli-MIC 322 mg/ml). The mixed-species biofilm exhibited better efficiency in removal of all tested metals than single-species biofilms. The highest efficiency in Cd 2+ removal was shown by the E. coli biofilm (94.85%) and R. mucilaginosa biofilm (97.85%), individually. The highest efficiency in Cu 2+ (99.88%), Zn 2+ (99.26%) and Pb 2+ (99.52%) removal was shown by the mixed-species biofilm. Metal removal efficiency was in the range of 81.56%-97.85% for the single- and 94.99%-99.88% for the mixed-species biofilm.
Shinde, P B; Katekhaye, S D; Mulik, M B; Laddha, K S
2014-09-01
The surge of interest in naturally occurring phytochemicals with high therapeutic potential has led to the discovery of many molecules, out of which naturally occuring coumarins such as marmelosin, umbelliferone and scopoletin present in Aegle marmelos (Bael) fruit shows good therapeutic potential. The aim of the present work is to develop and validate Reverse Phase-High Performance Liquid Chromatography (RP-HPLC) method for simultaneous determination of marmelosin, umbelliferone and scopoletin in A. marmelos fruit extracts. The chromatographic separation was performed with isocratic elution of 55:45 (%, v/v) methanol-water containing 0.1 % acetic acid as mobile phase. The method used to analyse the extract of A. marmelos showed good resolution with retention time within 12 min. The relative concentrations of above phytoconstituent were determined in A. marmelos fruits. The method was found to give compact peaks for scopoletin, umbelliferone and marmelosin (Rt of 4.6, 6.5 and 11.3 min respectively) and were linear over the range 5-30 μg ml(-1) (R(2) = 0.9655), 2-10 μg ml(-1) (R(2) = 0.9964) and 2-10 μg ml(-1) (R(2) = 0.9862) respectively. The mean recoveries for marmelosin, umbelliferone and scopoletin at three concentrations were in the range of 98.8-102.9, 98.8-101.1 and 94.2-98.3 % respectively. The relative standard deviation of accuracy, precision and repeatability were within 2 %, indicating the method produced highly reproducible results. Therefore this simple, precise and accurate method enables simultaneous separation of this phytoconstituent and hence can be successfully applied in analysis and routine quality control of herbal material and formulation containing A. marmelos.
Raines, C R; Dikeman, M E; Unruh, J A; Hunt, M C; Knock, R C
2008-12-01
This research explores the relationship between generally accepted and alternative cattle age-prediction methods and chronological age. Cattle (n = 386) of documented ages ranging from 370 to 1,115 d of age were used. Dentition (DEN), USDA maturity score (MS), lens weight (LW), and lens total N (LN) content were used as possible predictors of age. Correlations with age were determined: LW (r = 0.77); DEN (r = 0.74); LN (r = 0.71); and MS (r = 0.64). Stepwise backward regression was used to generate an age prediction equation: Age (mo) = -21.79 + 17.23(LW, g) + 0.038(DEN). By this equation, 38% of cattle = 20 mo of age were verified as = 20 mo of age. Independent measures verified the following percentages of cattle as = 20 mo of age: LW (20.2%), MS (11.0%), DEN (9.6%), and LN (8.7%). The DEN verified that 87.6% were verified as <30 mo old, and LW verified 81.6% of cattle as <30 mo old. A separate group of cattle (n = 18) ranging in age from 1 to 12 yr were evaluated for lens properties, for which LW (R(2) = 0.91) and LN (R(2) = 0.92) were highly correlated with age. The LW and DEN were the best predictors of age for cattle 13- to 37-mo-old and yielded the most accurate age prediction when used in combination (R(2) = 0.67).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aad, G.; Abbott, B.; Abdallah, J.
2015-09-01
Charged-particle spectra obtained in Pb+Pb interactions at √s NN=2.76 and pp interactions at √s NN=2.76 TeV with the ATLAS detector at the LHC are presented, using data with integrated luminosities of 0.15 nb -1 and 4.2 pb -1, respectively, in a wide transverse momentum (0.5 < p T < 150 GeV) and pseudorapidity (|η| < 2) range. For Pb+Pb collisions, the spectra are presented as a function of collision centrality, which is determined by the response of the forward calorimeters located on both sides of the interaction point. The nuclear modification factors R AA and R CP are presented inmore » detail as a function of centrality, p T and η. They show a distinct p T-dependence with a pronounced minimum at about 7 GeV. Above 60 GeV, R AA is consistent with a plateau at a centrality-dependent value, within the uncertainties. The value is 0.55 ± 0.01(stat.) ± 0.04(syst.) in the most central collisions. The R AA distribution is consistent with flat |η| dependence over the whole transverse momentum range in all centrality classes.« less
[Determination of aluminium in flour foods with photometric method].
Ma, Lan; Zhao, Xin; Zhou, Shuang; Yang, Dajin
2012-05-01
To establish a determination method for aluminium in flour foods with photometric method. After samples being treated with microwave digestion and wet digestion, aluminium in staple flour foods was determined by photometric method. There was a good linearity of the result in the range of 0.25 - 5.0 microg/ml aluminium, r = 0.9998; limit of detection (LOD) : 2.3 ng/ml; limit of quantitation (LOQ) : 7 ng/ml. This method of determining aluminium in flour foods is simple, rapid and reliable.
NASA Astrophysics Data System (ADS)
Aouidate, Adnane; Ghaleb, Adib; Ghamali, Mounir; Chtita, Samir; Choukrad, M'barek; Sbai, Abdelouahid; Bouachrine, Mohammed; Lakhlifi, Tahar
2017-07-01
A series of nineteen DHFR inhibitors was studied based on the combination of two computational techniques namely, three-dimensional quantitative structure activity relationship (3D-QSAR) and molecular docking. The comparative molecular field analysis (CoMFA) and comparative molecular similarity index analysis (CoMSIA) were developed using 19 molecules having pIC50 ranging from 9.244 to 5.839. The best CoMFA and CoMSIA models show conventional determination coefficients R2 of 0.96 and 0.93 as well as the Leave One Out cross-validation determination coefficients Q2 of 0.64 and 0.72, respectively. The predictive ability of those models was evaluated by the external validation using a test set of five compounds with predicted determination coefficients R2test of 0.92 and 0.94, respectively. The binding mode between this kind of compounds and the DHFR enzyme in addition to the key amino acid residues were explored by molecular docking simulation. Contour maps and molecular docking identified that the R1 and R2 natures at the pyrazole moiety are the important features for the optimization of the binding affinity to the DHFR receptor. According to the good concordance between the CoMFA/CoMSIA contour maps and docking results, the obtained information was explored to design novel molecules.
Patel, Archita; Macwana, Chhaya; Parmar, Vishal; Patel, Samir
2012-01-01
An accurate, simple, reproducible, and sensitive HPLC method was developed and validated for the simultaneous determination of atorvastatin calcium, ezetimibe, and fenofibrate in a tablet formulation. The analyses were performed on an RP C18 column, 150 x 4.60 mm id, 5 pm particle size. The mobile phase methanol-acetonitrile-water (76 + 13 + 11, v/v/v), was pumped at a constant flow rate of 1 mL/min. UV detection was performed at 253 nm. Retention times of atorvastatin calcium, ezetimibe, and fenofibrate were found to be 2.25, 3.68, and 6.41 min, respectively. The method was validated in terms of linearity, precision, accuracy, LOD, LOQ, and robustness. The response was linear in the range 2-10 microg/mL (r2 = 0.998) for atorvastatin calcium, 2-10 microg/mL (r2 = 0.998) for ezetimibe, and 40-120 microg/mL (r2 = 0.998) for fenofibrate. The developed method can be used for routine quality analysis of the drugs in the tablet formulation.
Bischoff, Karyn; Gaskill, Cynthia; Erb, Hollis N; Ebel, Joseph G; Hillebrandt, Joseph
2010-09-01
The current study compared the LeadCare(R) II test kit system with graphite-furnace atomic absorption spectrometry for blood lead (Pb) analysis in 56 cattle accidentally exposed to Pb in the field. Blood Pb concentrations were determined by LeadCare II within 4 hr of collection and after 72 hr of refrigeration. Blood Pb concentrations were determined by atomic absorption spectrometry, and samples that were coagulated (n = 12) were homogenized before analysis. There was strong rank correlation (R(2) = 0.96) between atomic absorption and LeadCare II (within 4 hr of collection), and a conversion formula was determined for values within the observed range (3-91 mcg/dl, although few had values >40 mcg/dl). Median and mean blood pb concentrations for atomic absorption were 7.7 and 15.9 mcg/dl, respectively; for LeadCare II, medians were 5.2 mcg/dl at 4 hr and 4.9 mcg/dl at 72 hr, and means were 12.4 and 11.7, respectively. LeadCare II results at 4 hr strongly correlated with 72 hr results (R(2) = 0.96), but results at 72 hr were lower (P < 0.01). There was no significant difference between coagulated and uncoagulated samples run by atomic absorption. Although there have been several articles that compared LeadCare with other analytical techniques, all were for the original system, not LeadCare II. The present study indicated that LeadCare II results correlated well with atomic absorption over a wide range of blood Pb concentrations and that refrigerating samples for up to 72 hr before LeadCare II analysis was acceptable for clinical purposes.
Obersky, Lizanne; Rafiee, Reza; Cabral, Alexandre R; Golding, Suzanne D; Clarke, William P
2018-06-01
An examination of the processes contributing to the production of landfill greenhouse gas (GHG) emissions is required, as the actual level to which waste degrades anaerobically and aerobically beneath covers has not been differentiated. This paper presents a methodology to distinguish between the rate of anaerobic digestion (r AD ), composting (r COM ) and CH 4 oxidation (r OX ) in a landfill environment, by means of a system of mass balances developed for molecular species (CH 4 , CO 2 ) and stable carbon isotopes (δ 13 C-CO 2 and δ 13 C-CH 4 ). The technique was applied at two sampling locations on a sloped area of landfill. Four sampling rounds were performed over an 18 month period after a 1.0 m layer of fresh waste and 30-50 cm of silty clay loam had been placed over the area. Static chambers were used to measure the flux of the molecular and isotope species at the surface and soil gas probes were used to collect gas samples at depths of approximately 0.5, 1.0 and 1.5 m. Mass balances were based on the surface flux and the concentration of the molecular and isotopic species at the deepest sampling depth. The sensitivity of calculated rates was considered by randomly varying stoichiometric and isotopic parameters by ±5% to generate at least 500 calculations of r OX , r AD and r COM for each location in each sampling round. The resulting average value of r AD and r COM indicated anaerobic digestion and composting were equally dominant at both locations. Average values of r COM : ranged from 9.8 to 44.5 g CO 2 m -2 d -1 over the four sampling rounds, declining monotonically at one site and rising then falling at the other. Average values of r AD: ranged from 10.6 to 45.3 g CO 2 m -2 d -1 . Although the highest average r AD value occurred in the initial sampling round, all subsequent r AD values fell between 10 and 20 g CO 2 m -2 d -1 . r OX had the smallest activity contribution at both sites, with averages ranging from 1.6 to 8.6 g CO 2 m -2 d -1 . This study has demonstrated that for an interim cover, composting and anaerobic digestion of shallow landfill waste can occur simultaneously. Copyright © 2018 Elsevier Ltd. All rights reserved.
[Determination of biphenyl ether herbicides in water using HPLC with cloud-point extraction].
He, Cheng-Yan; Li, Yuan-Qian; Wang, Shen-Jiao; Ouyang, Hua-Xue; Zheng, Bo
2010-01-01
To determine residues of multiple biphenyl ether herbicides simultaneously in water using high performance liquid chromatography (HPLC) with cloud-point extraction. The residues of eight biphenyl ether herbicides (including bentazone, fomesafen, acifluorfen, aclonifen, bifenox, fluoroglycofenethy, nitrofen, oxyfluorfen) in water samples were extracted with cloud-point extraction of Triton X-114. The analytes were separated and determined using reverse phase HPLC with ultraviolet detector at 300 nm. Optimized conditions for the pretreatment of water samples and the parameters of chromatographic separation applied. There was a good linear correlation between the concentration and the peak area of the analytes in the range of 0.05-2.00 mg/L (r = 0.9991-0.9998). Except bentazone, the spiked recoveries of the biphenyl ether herbicides in the water samples ranged from 80.1% to 100.9%, with relative standard deviations ranging from 2.70% to 6.40%. The detection limit of the method ranged from 0.10 microg/L to 0.50 microg/L. The proposed method is simple, rapid and sensitive, and can meet the requirements of determination of multiple biphenyl ether herbicides simultaneously in natural waters.
Chernyshov, Victor P; Vodyanik, Maxim A; Pisareva, Svetlana P
2005-11-01
Tumor necrosis factor (TNF) and soluble TNF receptors (sTNF-Rs) system related with Th1 and Th2 and activity of NF-kappaB/IkappaB regulatory system. This study was designed to compare sTNF-R1 and sTNF-R2 production (shedding) and levels of late activated CD8+ T-lymphocytes in non-pregnant (n = 30) and pregnant (n = 20) normal women and non-pregnant (n = 20) and pregnant (n = 30) RSA women. Effects of progesterone (natural structure) injections in RSA women were studied. Levels of sTNF-R1, sTNF-R2, TNF in peripheral blood serum were detected by enzyme-linked immunosorbent assay. Lymphocyte subsets were estimated by multicolor flow cytometry. NK cell cytotoxic activity of peripheral blood lymphocytes (PBL) in whole blood against K562 targets was determined using Europium-release cytotoxicity assay. Mitogen-induced proliferative response of PBL to PHA-P, Con A and PWM were determined by standard 3H-thymidine incorporation assay. Levels of soluble TNF-R1 and TNF-R2 in normal pregnancy were elevated when compared with non-pregnant normal women and pregnant RSA women. Levels of late activated CD8+ T-lymphocytes in normal pregnancy were decreased but no changes were detected in RSA women. After progesterone therapy (i.m. injections of 2.5% oil solution) in RSA women elevation of sTNF-R1 and sTNF-R2 to normal pregnancy ranges was observed. No changes in levels of late activated CD8+ T-lymphocytes after progesterone treatment were detected. Elevation of levels of sTNF-R1, sTNF-R2 and decrease of late activated cytotoxic T-lymphocytes are pronounce markers of normal human pregnancy. In RSA women there are no elevation of sTNF-R1 and sTNF-R2 levels during pregnancy. This deficiency may be restored by progesterone treatment.
Properties of Ni^+ from microwave spectroscopy of n=9 Rydberg levels of Nickel
NASA Astrophysics Data System (ADS)
Woods, Shannon; Keele, Julie; Smith, Chris; Lundeen, Stephen
2012-06-01
The microwave/RESIS method was used to determine the relative positions of 15 of the n=9 Rydberg levels of Nickel with L >= 6. Because the ground state of the Ni^+ ion is a ^2D5/2 level, each Rydberg level (n,L) splits into six eigenstates whose relative positions are determined by long-range e-Ni^+ interactions present in addition to the dominant Coulomb interaction. A previous study with the optical RESIS method determined these positions with precision of +/- 30 MHz [1]. Using the microwave/RESIS method improves that precision by a factor of 300, and leads to much improved determinations of the Ni+ properties that control the long-range interactions. [4pt] [1] Julie A. Keele, Shannon L. Woods, M.E. Hanni, and S.R. Lundeen Phys. Rev. 81, 022506 (2010)
Spectrophotometric and theoretical studies of the protonation of Allura Red AC and Ponceau 4R
NASA Astrophysics Data System (ADS)
Bevziuk, Kateryna; Chebotarev, Alexander; Snigur, Denys; Bazel, Yaroslav; Fizer, Maksym; Sidey, Vasyl
2017-09-01
The acid-base properties of Allura Red AC and Ponceau 4R azo dyes were investigated by spectrophotometric, potentiometric and tristimulus colourimetry methods. Ionization constants of the functional groups were also found in aqueous solutions of the dyes. It was discovered that the wavelength of the maximum light absorption of Allura Red AC and Ponceau 4R solutions does not change significantly over a wide pH range. As a result, spectrophotometric methods yield little information for assessing the acid-base properties of the dyes. It was shown with a help of the tristimulus colourimetry method that it is possible to determine the ionization constants of the functional groups of the dyes even when there is significant overlap of the absorption bands of the acid-base forms. The basic spectrophotometric characteristics of the main forms of Allura Red AC and Ponceau 4R in water and organic solvents were calculated. The molar absorbance coefficients of azo forms were shown to increase as the dielectric permittivity of the solvent increases. It was determined that in aqueous solution the dyes exist in the azo form over a wide range of acidity - pH 2-12 for Allura Red AC (λmax = 505 nm; ελ = 3.1·104 dm3 mol-1 cm-1) and 1-13 for Ponceau 4R (λmax = 510 nm; ελ = 1.7·10-4 dm3 mol-1 cm-1). The most probable protonation/deprotonation schemes were theoretically determined for Allura Red AC and Ponceau 4R using DFT calculations.
Thijs, Lutgarde; Staessen, Jan; Amery, Antoon; Bruaux, Pierre; Buchet, Jean-Pierre; Claeys, FranÇoise; De Plaen, Pierre; Ducoffre, Geneviève; Lauwerys, Robert; Lijnen, Paul; Nick, Laurence; Remy, Annie Saint; Roels, Harry; Rondia, Désiré; Sartor, Francis
1992-01-01
This report investigated the distribution of serum zinc and the factors determining serum zinc concentration in a large random population sample. The 1977 participants (959 men and 1018 women), 20–80 years old, constituted a stratified random sample of the population of four Belgian districts, representing two areas with low and two with high environmental exposure to cadmium. For each exposure level, a rural and an urban area were selected. The serum concentration of zinc, frequently used as an index for zinc status in human subjects, was higher in men (13.1 μmole/L, range 6.5–23.0 μmole/L) than in women (12.6 μmole/L, range 6.3–23.2 μmole/L). In men, 20% of the variance of serum zinc was explained by age (linear and squared term, R = 0.29), diurnal variation (r = 0.29), and total cholesterol (r = 0.16). After adjustment for these covariates, a negative relationship was observed between serum zinc and both blood (r = −0.10) and urinary cadmium (r = −0.14). In women, 11% of the variance could be explained by age (linear and squared term, R = 0.15), diurnal variation in serum zinc (r = 0.27), creatinine clearance (r = −0.11), log γ-glutamyltranspeptidase (r = 0.08), cholesterol (r = 0.07), contraceptive pill intake (r = −0.07), and log serum ferritin (r = 0.06). Before and after adjustment for significant covariates, serum zinc was, on average, lowest in the two districts where the body burden of cadmium, as assessed by urinary cadmium excretion, was highest. These results were not altered when subjects exposed to heavy metals at work were excluded from analysis. PMID:1486857
Andersen, Michael P; Nielsen, Karin K
2003-05-05
A sensitive and specific LC/MS/MS method has been developed and validated for determination of ragaglitazar (NNC 61-0029 or DRF 2725) in human plasma. After solid-phase extraction (SPEC((R)) PLUS C(8)) of plasma, separation was performed on a Symmetry Shield RP8 column (mobile phase: acetonitrile: 10 mM ammonium acetate, pH 5.6 (40:60 v/v)). Two ranges were validated having LLOQs of either 0.500 or 100 ng/ml and linearity up to either 500 or 50000 ng/ml. The intra-assay precision and accuracy were 1.1% to 15.7% and 85.8% to 118.2% (range 0.500-500 ng/ml) and 2.0% to 8.8% and 92.9% to 104.8% (range 100-50000 ng/ml). The method was applied for determination of ragaglitazar in plasma from phase 1 and 2 clinical studies.
NASA Astrophysics Data System (ADS)
Kabata, Yasuo; Higashi, Yukihiro; Uematsu, Masahiko; Watanabe, Koichi
Measurements of the vapor-liquid coexistence curve in the critical region for the refrigerant mixture of R152a (CH3CHF2: 1, l-difluoroethane) +R 114 (CCIF2CCIF2 :1, 2-dichloro-1, 1, 2, 2-tetrafluoroethane) system were made by visual observation of the disappearance of the meniscus at the vapor-liquid interface within an optical cell. Forty-eight saturated densities along the vapor-liquid coexistence curve between 204 and 861 kg·m-3 for five different compositions of 10, 20, 50, 80 and 90 wt% R 152a were obtained in the temperature range 370 to 409 K. The experimental errors of temperature, density, and mass fraction were estimated within ±10mK, ±0.5% and +0.05 %, respectively. On the basis of these measurements, the critical parameters of five different compositions for the R 152a +R 114 system were determined in consideration of the meniscus disappearance level as well as intensity of the critical opalescence. In accordance with the previous results of three other refrigerant mixtures, i.e., R 12 +R 22 system, R 22 +R 114 system and R 13B1 + R 114 system, the coexistence curve and critical curve on the temperature-density diagram for binary refrigerant mixtures were discussed. In addition, correlations of its composition dependence for this system were proposed.
Metabolic rates in an anadromous clupeid, the American shad (Alosa sapidissima)
Leonard, J.B.K.; Norieka, J.F.; Kynard, B.; McCormick, S.D.
1999-01-01
To assess the energetics of migration in an anadromous fish, adult American shad (Alosa sapidissima) were swum in a large respirometer at a range of speeds (1.0–2.3 body lengths (BL) s−1, 13–24 °C). Metabolic rate (MO2) was logarithmically related to swimming speed (Bl s−1; r2 = 0.41, slope = 0.23 ± 0.037) and tailbeat frequency (beats × min−1; r2 = 0.52, slope = 0.003 ± 0.0003). Temperature had a significant effect on metabolic rate (r2 = 0.41) with a Q10of 2.2. Standard metabolic rate (SMR), determined directly after immobilization with the neuroblocker gallamine triethiodide, ranged from 2.2–6.2 mmolO2 kg−1 h−1 and scaled with mass (W) such that SMR = 4.0 (±0.03)W0.695(±0.15). Comparison of directly determined and extrapolated SMR suggests that swimming respirometry provides a good estimate of SMR in this species, given the differences in basal activity monitored by the two methods. Overall, American shad metabolic rates (MO2 and SMR) were intermediate between salmonids and fast-swimming perciforms, including tunas, and may be a result of evolutionary adaptation to their active pelagic, schooling life history. This study demonstrates variability in metabolic strategy among anadromous fishes that may be important to understanding the relative success of different migratory species under varying environmental conditions.
NASA Astrophysics Data System (ADS)
Babić-Stojić, Branka; Jokanović, Vukoman; Milivojević, Dušan; Požek, Miroslav; Jagličić, Zvonko; Makovec, Darko; Arsikin, Katarina; Paunović, Verica
2016-04-01
Gd2O3 nanoparticles of a few nm in size and their agglomerates dispersed in dextrose derived polymer template were synthesized by hydrothermal treatment. The produced nanosized material was investigated by TEM, FTIR spectroscopy, SQUID measurements and NMR relaxometry. Biological evaluation of this material was done by crystal violet and MTT assays to determine the cell viability. Longitudinal and transverse NMR relaxivities of water diluted Gd2O3 nanoparticle dispersions measured at the magnetic field of 1.5 T, estimated to be r1(Gd2O3)=9.6 s-1 mM-1 in the Gd concentration range 0.1-30 mM and r2(Gd2O3)=17.7 s-1 mM-1 in the lower concentration range 0.1-0.8 mM, are significantly higher than the corresponding relaxivities measured for the standard contrast agent r1(Gd-DTPA)=4.1 s-1 mM-1 and r2(Gd-DTPA)=5.1 s-1 mM-1. The ratio of the two relaxivities for Gd2O3 nanoparticles r2/r1=1.8 is suitable for T1-weighted imaging. Good MRI signal intensities of the water diluted Gd2O3 nanoparticle dispersions were recorded at lower Gd concentrations 0.2-0.8 mM. The Gd2O3 samples did not exert any significant cytotoxic effects at Gd concentrations of 0.2 mM and below. These properties of the produced Gd2O3 nanoparticles in hydrothermally modified dextrose make them promising for potential application in MRI for the design of a positive MRI contrast agent.
Kinetic and thermochemical studies of the ClO + ClO + M ↔ Cl2O2 + M reaction
NASA Astrophysics Data System (ADS)
Ferracci, V.; Rowley, D. M.
2009-12-01
Chlorine monoxide (ClO) radicals play a crucial role in polar ozone destruction events and the ClO dimer cycle has been identified as one of the most effective ozone-depleting catalytic cycles operating in the polar winter. A recent paper by von Hobe et al.1 highlighted significant inconsistencies between laboratory results, theoretical calculations and field observations concerning the ClO dimer ozone destruction cycle. This work has investigated the temperature dependence of the equilibrium constant of one of the key reactions in this cycle, ClO + ClO + M ↔ Cl2O2 + M (1, -1), by means of laser flash photolysis coupled with time-resolved UV absorption spectroscopy. ClO radicals were generated via laser flash photolysis of Cl2/Cl2O mixtures in synthetic air. The concentration of radicals was monitored via UV absorption spectroscopy: the use of a Charge Coupled Device (CCD) detector allowed time resolution over a broad range of wavelengths. The equilibrium constant Keq was determined as the ratio of the rate constants of the forward and reverse reaction (1, -1) over the T range 256 - 312 K. Second Law and Third Law analytical methods were employed to determine the standard enthalpy and entropy changes of reaction 1, ΔrH° and ΔrS°, from the measured equilibrium constants. The values obtained from the Second Law analysis (ΔrH° = - 80.8 ± 2.2 kJ mol-1; ΔrS° = - 168.4 ± 7.9 J K-1 mol-1) are in good agreement with previous work 2 but greater in magnitude than current NASA recommendations 3. It was also found that, under typical laboratory conditions employed in this work, [ClO] decay exhibits pure second order kinetics at T ≤ 250 K. A higher rate constant for the ClO recombination reaction (1) was also observed in this work (compared to the NASA evaluation 3), implying a higher Keq and a different partitioning between ClO and Cl2O2, shifting towards the dimer. 1. M. Von Hobe, R. J. Salawitch, T. Canty, H. Keller-Rudek, G. K. Moortgat, J.-U. Grooss, R. Müller, F. Stroh, Atmospheric Chemistry and Physics, 2007, 7, 3055 2. S. L. Nickolaisen, R. R. Friedl, S. P. Sander, Journal of Physical Chemistry, 1994, 98, 155 3. S. P. Sander, R. R. Friedl, D. M. Golden, M. J. Kurylo, R. E. Huie, V. L. Orkin, G. K. Moortgat, A. R. Ravishankara, C. E. Kolb, M. J. Molina, B. J. Finlayson-Pitts, Chemical Kinetics and Photochemical Data for use in Atmospheric Studies, Evaluation No. 14, JPL Publication 02-25, NASA Jet Propulsion Laboratory, Pasadena CA, 2003
Determinants of iron accumulation in the normal aging brain.
Pirpamer, Lukas; Hofer, Edith; Gesierich, Benno; De Guio, François; Freudenberger, Paul; Seiler, Stephan; Duering, Marco; Jouvent, Eric; Duchesnay, Edouard; Dichgans, Martin; Ropele, Stefan; Schmidt, Reinhold
2016-07-01
In a recent postmortem study, R2* relaxometry in gray matter (GM) of the brain has been validated as a noninvasive measure for iron content in brain tissue. Iron accumulation in the normal aging brain is a common finding and relates to brain maturation and degeneration. The goal of this study was to assess the determinants of iron accumulation during brain aging. The study cohort consisted of 314 healthy community-dwelling participants of the Austrian Stroke Prevention Study. Their age ranged from 38-82 years. Quantitative magnetic resonance imaging was performed on 3T and included R2* mapping, based on a 3D multi-echo gradient echo sequence. The median of R2* values was measured in all GM regions, which were segmented automatically using FreeSurfer. We investigated 25 possible determinants for cerebral iron deposition. These included demographics, brain volume, lifestyle factors, cerebrovascular risk factors, serum levels of iron, and single nucleotide polymorphisms related to iron regulating genes (rs1800562, rs3811647, rs1799945, and rs1049296). The body mass index (BMI) was significantly related to R2* in 15/32 analyzed brain regions with the strongest correlations found in the amygdala (p = 0.0091), medial temporal lobe (p = 0.0002), and hippocampus (p ≤ 0.0001). Further associations to R2* values were found in deep GM for age and smoking. No significant associations were found for gender, GM volume, serum levels of iron, or iron-associated genetic polymorphisms. In conclusion, besides age, the BMI and smoking are the only significant determinants of brain iron accumulation in normally aging subjects. Smoking relates to iron deposition in the basal ganglia, whereas higher BMI is associated with iron content in the neocortex following an Alzheimer-like distribution. Copyright © 2016 Elsevier Inc. All rights reserved.
Temperature dependence of vibrational relaxation in the HF, DF, HF-CO2, and DF-CO2 systems
NASA Technical Reports Server (NTRS)
Lucht, R. A.; Cool, T. A.
1974-01-01
The laser excited fluorescence method has been employed to determine rate constants for V to V, R and V to R, T relaxation HF (nu = 1) and DF(nu = 1) by CO2 over the temperature range from 295 to 670 K. The self-deactivation rates for HF(nu = 1) and DF(nu = 1) by ground state molecules and the rate of V to V, R transfer from HF(nu = 1) and DF(nu = 1) to the CO2 (00/0/1) state exhibit a marked decrease with increasing temperature. The results provide additional evidence for the conversion of the large vibrational energy defects of the present systems into rotational motion of the hydrogen halide under the influence of a sizable attractive intermolecular potential well.
Using squat testing to predict training loads for lower-body exercises in elite karate athletes.
Wong, Del P; Tan, Erik C H; Chaouachi, Anis; Carling, Christopher; Castagna, Carlo; Bloomfield, Jonathan; Behm, David G
2010-11-01
The purpose of this study was to determine the relationship between squat loads and 2 bilateral and 2 unilateral stepping lower-body exercises in predominantly unilateral movement elite athletes (Karate). Equations to predict loads for lower-body exercises based on the squat load were also determined. Fourteen male elite Karate athletes (age = 22.6 ± 1.2 years) performed 6 repetition maximum (RM) of the following free-weight bilateral exercises: back half squat, deadlift, leg press and unilateral stepping exercises, lunge; and step-up. Results showed that 6RM squat load was significantly (p < 0.001) correlated with deadlift (r = 0.86), leg press (r = 0.76), lunge (r = 0.86), and step-up (r = 0.92). Linear regression showed that the 6RM squat load was a significant predictor for deadlift, leg press, lunge, and step-up (R2 range from 0.57 to 0.85, p < 0.001). The following 6RM prediction equations were determined: (a) Deadlift = squat load (1.12)-16.60 kg, (b) Leg press = squat load (1.66) + 16.10 kg, (c) Lunge = squat load (0.61) + 9.39 kg, and (d) step-up = squat load (0.85)-10.36 kg. Coaches and fitness professionals can use the 6RM squat load as a time effective and accurate method to predict training loads for both bilateral and unilateral lower-body exercises with quadriceps as the prime mover. Load prescriptions for unilateral exercises should take into account the type of athletic population.
Manjunatha, Revanasiddappa; Shivappa Suresh, Gurukar; Melo, Jose Savio; D'Souza, Stanislaus F; Venkatesha, Thimmappa Venkatarangaiah
2012-09-15
Cholesterol oxidase (ChOx) and cholesterol esterase (ChEt) have been covalently immobilized onto functionalized graphene (FG) modified graphite electrode. Enzymes modified electrodes were characterized using cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). FG accelerates the electron transfer from electrode surface to the immobilized ChOx, achieving the direct electrochemistry of ChOx. A well defined redox peak was observed, corresponding to the direct electron transfer of the FAD/FADH(2) of ChOx. The electron transfer coefficient (α) and electron transfer rate constant (K(s)) were calculated and their values are found to be 0.31 and 0.78 s(-1), respectively. For the free cholesterol determination, ChOx-FG/Gr electrode exhibits a sensitive response from 50 to 350 μM (R=-0.9972) with a detection limit of 5 μM. For total cholesterol determination, co-immobilization of ChEt and ChOx on modified electrode, i.e. (ChEt/ChOx)-FG/Gr electrode showed linear range from 50 to 300 μM (R=-0.9982) with a detection limit of 15 μM. Some common interferents like glucose, ascorbic acid and uric acid did not cause any interference, due to the use of a low operating potential. The FG/Gr electrode exhibits good electrocatalytic activity towards hydrogen peroxide (H(2)O(2)). A wide linear response to H(2)O(2) ranging from 0.5 to 7 mM (R=-0.9967) with a sensitivity of 443.25 μA mM(-1) cm(-2) has been obtained. Copyright © 2012 Elsevier B.V. All rights reserved.
Signals of a 2 TeV $W'$ boson and a heavier $Z'$ boson
Dobrescu, Bogdan A.; Fox, Patrick J.
2016-05-09
We construct an SU(2) L x SU(2) R x U(1) B-L model with a Higgs sector that consists of a bidoublet and a doublet, and with a right-handed neutrino sector that includes one Dirac fermion and one Majorana fermion. This model explains the CMS and ATLAS excess events in the e +e -jj, jj, Wh 0 and WZ channels in terms of a W' boson of mass near 1.9 TeV and of coupling g R in the 0.4-0.5 range (with the lower half preferred by the limits on tb-bar resonances). We found that the production cross section of this W'more » boson at the 13 TeV LHC is in the 720-1100 fb range, allowing sensitivity in more than 17 final states. Furthermore, we determine that the Z' boson has a mass in the 2.9-4.5 TeV range and several decay channels that can be probed in Run 2 of the LHC, including cascade decays via heavy Higgs bosons. Interpreting the CMS e +e -event at 2.9 TeV as coming from the Z', the mass ratio of the Z' and W' bosons requires g R ≈0.48, which implies a pp →Z' → ℓ +ℓ -cross section of 2 fb at √s = 13 TeV.« less
[Determination of four alkaloids in Corydalis decumbens by HPLC].
Shen, Yan; Han, Chao; Xia, Biqi; Zhou, Yongfang; Liu, Cuiping; Liu, Aili
2011-08-01
To establish a quantitative HPLC method for determination of protopine, palmatine hydrochloride, bicuculline and tetrahydropalmatine, in Corydalis decumbens. The separation was performed on a ZORBAX Eclipse XDB-C18 column (4.6 mm x 150 mm, 5 microm) at a flow rate of 1.0 mL x min(-1) using mixtures of two solvents [A(20 mmol x L(-1) ammonium acetate)-B(acetonitrile)]: with a gradient elution. The column oven temperature was 30 degrees C and the detection wavelength was set at 280 nm. The 4 alkaloids were well separated by this HPLC method. Linearifies of protopine, palmatine hydrochloride, bicuculline and tetrahydropalmatine were good in the ranges of 1.44-46.0 (r = 0.999 4), 1.2640.2 (r = 0.999 8), 1.37-44.0 (r = 0.999 9), and 1.3643.6 mg x L(-1) (r = 0.999 9), respectively. The average recoveries were 98.2% with RSD 2.7% for protopine, 101.9% with RSD 2.5% for palmatine hydrochloride, 102.8% with RSD 3.5% for tetrahydropalmatine, and 98.8% with RSD 3.1% for tetrahydropalmatine. This method is proved to be convenient, reliable and accurate., and it can be used for quality control of C. decumbens.
Size and shape of soil humic acids estimated by viscosity and molecular weight.
Kawahigashi, Masayuki; Sumida, Hiroaki; Yamamoto, Kazuhiko
2005-04-15
Ultrafiltration fractions of three soil humic acids were characterized by viscometry and high performance size-exclusion chromatography (HPSEC) in order to estimate shapes and hydrodynamic sizes. Intrinsic viscosities under given solute/solvent/temperature conditions were obtained by extrapolating the concentration dependence of reduced viscosities to zero concentration. Molecular mass (weight average molecular weight (M (w)) and number average molecular weight (M (n))) and hydrodynamic radius (R(H)) were determined by HPSEC using pullulan as calibrant. Values of M (w) and M (n) ranged from 15 to 118 x 10(3) and from 9 to 50 x 10(3) (g mol(-1)), respectively. Polydispersity, as indicated by M (w)/M (n), increased with increasing filter size from 1.5 to 2.4. The hydrodynamic radii (R(H)) ranged between 2.2 and 6.4 nm. For each humic acid, M (w) and [eta] were related. Mark-Houwink coefficients calculated on the basis of the M (w)-[eta] relationships suggested restricted flexible chains for two of the humic acids and a branched structure for the third humic acid. Those structures probably behave as hydrated sphere colloids in a good solvent. Hydrodynamic radii of fractions calculated from [eta] using Einstein's equation, which is applicable to hydrated sphere colloids, ranged from 2.2 to 7.1 nm. These dimensions are fit to the size of nanospaces on and between clay minerals and micropores in soil particle aggregates. On the other hand, the good agreement of R(H) values obtained by applying Einstein's equation with those directly determined by HPSEC suggests that pullulan is a suitable calibrant for estimation of molecular mass and size of humic acids by HPSEC.
Shu, Xiaoyun; Tang, Yuping; Jiang, Chenxue; Shang, Erxing; Fan, Xinshen; Ding, Anwei
2012-11-01
A high performance liquid chromatographic (HPLC) method with diode array detection (DAD) was established for simultaneous determination of seven main bioactive components in San-ao decoction and its series of formulae (San-ao decoction, Wu-ao decoction, Qi-ao decoction and Jia-wei San-ao decoction). Seven compounds were analyzed simultaneously with a XTerra C(18) column (4.6 mm × 250 mm, 5 µm) using a linear gradient elution of a mobile phase containing acetonitrile (A) and a buffer solution (0.02 mol/L potassium dihydrogen phosphate and adjusted to pH 3 using phosphoric acid) (B); the flow rate was 1.0 mL/min. The sample was detected with DAD at 210, 254 and 360 nm and the column was maintained at 30 °C. All the compounds showed good linearity (r2 > 0.9984) in the tested concentration range. The precisions were evaluated by intra-day and inter-day tests, and relative standard deviation (R.S.D.) values within the range of 0.83%–2.53% and 0.64%–2.77% were reported, respectively. The recoveries of the quantified compounds were observed to cover a range from 95.34% and 104.82% with R.S.D. values less than 2.72%. The validated method was successfully applied for the simultaneous determination of seven main bioactive components including ephedrine (1), amygdalin (2), liquiritin (3), benzoic acid (4), isoliquiritin (5), formononetin (6) and glycyrrhizic acid (7) in San-ao decoction and its series of formulae. The results also showed a wide variation in the content of the identified active compounds in these samples, which could also be helpful to illustrate the drug interactions after some herbs combined in different formulations.
Li, Zhong-Min; Giesert, Florian; Vogt-Weisenhorn, Daniela; Main, Katharina Maria; Skakkebæk, Niels Erik; Kiviranta, Hannu; Toppari, Jorma; Feldt-Rasmussen, Ulla; Shen, Heqing; Schramm, Karl-Werner; De Angelis, Meri
2018-01-26
The transplacental passage of thyroid hormones (THs) is of great significance since the maternal THs are vitally important in ensuring the normal fetal development. In this paper, we determined the concentrations of seven THs, viz. L-thyroxine (T 4 ), 3,3',5-triiodo-l-thyronine (T 3 ), 3,3',5'-triiodo-l-thyronine (rT 3 ), 3,3'-diiodo-l-thyronine (T 2 ), 3,5-diiodo-l-thyronine (rT 2 ), 3-iodo-l-thyronine (T 1 ) and 3-iodothyronamine (T 1 AM), in placenta using isotope dilution liquid chromatography quadrupole time-of-flight mass spectrometry. We optimized the method using isotopically labeled quantification standards ( 13 C 6 -T 4 , 13 C 6 -T 3 , 13 C 6 -rT 3 and 13 C 6 -T 2 ) and recovery standard ( 13 C 12 -T 4 ) in combination with solid-liquid extraction, liquid-liquid extraction and solid phase extraction. The linearity was obtained in the range of 0.5-150 pg uL -1 with R 2 values >0.99. The method detection limits (MDLs) ranged from 0.01 ng g -1 to 0.2 ng g -1 , while the method quantification limits (MQLs) were between 0.04 ng g -1 and 0.7 ng g -1 . The spike-recoveries for THs (except for T 1 and T 1 AM) were in the range of 81.0%-112%, with a coefficient of variation (CV) of 0.5-6.2%. The intra-day CVs and inter-day CVs were 0.5%-10.3% and 1.19%-8.88%, respectively. Concentrations of the THs were 22.9-35.0 ng g -1 T 4 , 0.32-0.46 ng g -1 T 3 , 2.86-3.69 ng g -1 rT 3 , 0.16-0.26 ng g -1 T 2 , and < MDL for other THs in five human placentas, and 2.05-3.51 ng g -1 T 4 , 0.37-0.62 ng g -1 T 3 , 0.96-1.3 ng g -1 rT 3 , 0.07-0.13 ng g -1 T 2 and < MDL for other THs in five mouse placentas. The presence of T 2 was tracked in placenta for the first time. This method with improved selectivity and sensitivity allows comprehensive evaluation of TH homeostasis in research of metabolism and effects of environmental contaminant exposures. Copyright © 2017 Elsevier B.V. All rights reserved.
Aad, G.
2015-09-09
Charged-particle spectra obtained in Pb+Pb interactions at \\( \\sqrt{s_{\\mathrm{NN}}}=2.76 \\) TeV and pp interactions at \\( \\sqrt{s_{\\mathrm{NN}}}=2.76 \\) TeV with the ATLAS detector at the LHC are presented, using data with integrated luminosities of 0.15 nb⁻¹ and 4.2 pb⁻¹, respectively, in a wide transverse momentum (0.5 < p T < 150 GeV) and pseudorapidity (|η| < 2) range. For Pb+Pb collisions, the spectra are presented as a function of collision centrality, which is determined by the response of the forward calorimeters located on both sides of the interaction point. The nuclear modification factors R AA and R CP are presentedmore » in detail as a function of centrality, p T and η. They show a distinct p T-dependence with a pronounced minimum at about 7 GeV. Above 60 GeV, R AA is consistent with a plateau at a centrality-dependent value, within the uncertainties. The value is 0.55 ± 0.01(stat.) ± 0.04(syst.) in the most central collisions. The R AA distribution is consistent with flat |η| dependence over the whole transverse momentum range in all centrality classes.« less
NASA Astrophysics Data System (ADS)
Aad, G.; Abbott, B.; Abdallah, J.; Abdel Khalek, S.; Abdinov, O.; Aben, R.; Abi, B.; Abolins, M.; AbouZeid, O. S.; Abramowicz, H.; Abreu, H.; Abreu, R.; Abulaiti, Y.; Acharya, B. S.; Adamczyk, L.; Adams, D. L.; Adelman, J.; Adomeit, S.; Adye, T.; Agatonovic-Jovin, T.; Aguilar-Saavedra, J. A.; Agustoni, M.; Ahlen, S. P.; Ahmadov, F.; Aielli, G.; Akerstedt, H.; Åkesson, T. P. A.; Akimoto, G.; Akimov, A. V.; Alberghi, G. L.; Albert, J.; Albrand, S.; Alconada Verzini, M. J.; Aleksa, M.; Aleksandrov, I. N.; Alexa, C.; Alexander, G.; Alexandre, G.; Alexopoulos, T.; Alhroob, M.; Alimonti, G.; Alio, L.; Alison, J.; Allbrooke, B. M. M.; Allison, L. J.; Allport, P. P.; Aloisio, A.; Alonso, A.; Alonso, F.; Alpigiani, C.; Altheimer, A.; Alvarez Gonzalez, B.; Alviggi, M. G.; Amako, K.; Amaral Coutinho, Y.; Amelung, C.; Amidei, D.; Amor Dos Santos, S. P.; Amorim, A.; Amoroso, S.; Amram, N.; Amundsen, G.; Anastopoulos, C.; Ancu, L. S.; Andari, N.; Andeen, T.; Anders, C. F.; Anders, G.; Anderson, K. J.; Andreazza, A.; Andrei, V.; Anduaga, X. S.; Angelidakis, S.; Angelozzi, I.; Anger, P.; Angerami, A.; Anghinolfi, F.; Anisenkov, A. V.; Anjos, N.; Annovi, A.; Antonelli, M.; Antonov, A.; Antos, J.; Anulli, F.; Aoki, M.; Aperio Bella, L.; Arabidze, G.; Arai, Y.; Araque, J. P.; Arce, A. T. H.; Arduh, F. A.; Arguin, J.-F.; Argyropoulos, S.; Arik, M.; Armbruster, A. J.; Arnaez, O.; Arnal, V.; Arnold, H.; Arratia, M.; Arslan, O.; Artamonov, A.; Artoni, G.; Asai, S.; Asbah, N.; Ashkenazi, A.; Åsman, B.; Asquith, L.; Assamagan, K.; Astalos, R.; Atkinson, M.; Atlay, N. B.; Auerbach, B.; Augsten, K.; Aurousseau, M.; Avolio, G.; Axen, B.; Ayoub, M. K.; Azuelos, G.; Baak, M. A.; Baas, A. E.; Bacci, C.; Bachacou, H.; Bachas, K.; Backes, M.; Backhaus, M.; Bagiacchi, P.; Bagnaia, P.; Bai, Y.; Bain, T.; Baines, J. T.; Baker, O. K.; Balek, P.; Balestri, T.; Balli, F.; Banas, E.; Banerjee, Sw.; Bannoura, A. A. E.; Bansil, H. S.; Barak, L.; Barberio, E. L.; Barberis, D.; Barbero, M.; Barillari, T.; Barisonzi, M.; Barklow, T.; Barlow, N.; Barnes, S. L.; Barnett, B. M.; Barnett, R. M.; Barnovska, Z.; Baroncelli, A.; Barone, G.; Barr, A. J.; Barreiro, F.; Barreiro Guimarães da Costa, J.; Bartoldus, R.; Barton, A. E.; Bartos, P.; Bassalat, A.; Basye, A.; Bates, R. L.; Batista, S. J.; Batley, J. R.; Battaglia, M.; Bauce, M.; Bauer, F.; Bawa, H. S.; Beacham, J. B.; Beattie, M. D.; Beau, T.; Beauchemin, P. H.; Beccherle, R.; Bechtle, P.; Beck, H. P.; Becker, K.; Becker, S.; Beckingham, M.; Becot, C.; Beddall, A. J.; Beddall, A.; Bednyakov, V. A.; Bee, C. P.; Beemster, L. J.; Beermann, T. A.; Begel, M.; Behr, J. K.; Belanger-Champagne, C.; Bell, P. J.; Bell, W. H.; Bella, G.; Bellagamba, L.; Bellerive, A.; Bellomo, M.; Belotskiy, K.; Beltramello, O.; Benary, O.; Benchekroun, D.; Bender, M.; Bendtz, K.; Benekos, N.; Benhammou, Y.; Benhar Noccioli, E.; Benitez Garcia, J. A.; Benjamin, D. P.; Bensinger, J. R.; Bentvelsen, S.; Beresford, L.; Beretta, M.; Berge, D.; Bergeaas Kuutmann, E.; Berger, N.; Berghaus, F.; Beringer, J.; Bernard, C.; Bernard, N. R.; Bernius, C.; Bernlochner, F. U.; Berry, T.; Berta, P.; Bertella, C.; Bertoli, G.; Bertolucci, F.; Bertsche, C.; Bertsche, D.; Besana, M. I.; Besjes, G. J.; Bessidskaia Bylund, O.; Bessner, M.; Besson, N.; Betancourt, C.; Bethke, S.; Bevan, A. J.; Bhimji, W.; Bianchi, R. M.; Bianchini, L.; Bianco, M.; Biebel, O.; Bieniek, S. P.; Biglietti, M.; Bilbao De Mendizabal, J.; Bilokon, H.; Bindi, M.; Binet, S.; Bingul, A.; Bini, C.; Black, C. W.; Black, J. E.; Black, K. M.; Blackburn, D.; Blair, R. E.; Blanchard, J.-B.; Blanco, J. E.; Blazek, T.; Bloch, I.; Blocker, C.; Blum, W.; Blumenschein, U.; Bobbink, G. J.; Bobrovnikov, V. S.; Bocchetta, S. S.; Bocci, A.; Bock, C.; Boddy, C. R.; Boehler, M.; Bogaerts, J. A.; Bogdanchikov, A. G.; Bohm, C.; Boisvert, V.; Bold, T.; Boldea, V.; Boldyrev, A. S.; Bomben, M.; Bona, M.; Boonekamp, M.; Borisov, A.; Borissov, G.; Borroni, S.; Bortfeldt, J.; Bortolotto, V.; Bos, K.; Boscherini, D.; Bosman, M.; Boudreau, J.; Bouffard, J.; Bouhova-Thacker, E. V.; Boumediene, D.; Bourdarios, C.; Bousson, N.; Boutouil, S.; Boveia, A.; Boyd, J.; Boyko, I. R.; Bozic, I.; Bracinik, J.; Brandt, A.; Brandt, G.; Brandt, O.; Bratzler, U.; Brau, B.; Brau, J. E.; Braun, H. M.; Brazzale, S. F.; Brendlinger, K.; Brennan, A. J.; Brenner, L.; Brenner, R.; Bressler, S.; Bristow, K.; Bristow, T. M.; Britton, D.; Britzger, D.; Brochu, F. M.; Brock, I.; Brock, R.; Bronner, J.; Brooijmans, G.; Brooks, T.; Brooks, W. K.; Brosamer, J.; Brost, E.; Brown, J.; Bruckman de Renstrom, P. A.; Bruncko, D.; Bruneliere, R.; Bruni, A.; Bruni, G.; Bruschi, M.; Bryngemark, L.; Buanes, T.; Buat, Q.; Bucci, F.; Buchholz, P.; Buckley, A. G.; Buda, S. I.; Budagov, I. A.; Buehrer, F.; Bugge, L.; Bugge, M. K.; Bulekov, O.; Burckhart, H.; Burdin, S.; Burghgrave, B.; Burke, S.; Burmeister, I.; Busato, E.; Büscher, D.; Büscher, V.; Bussey, P.; Buszello, C. P.; Butler, J. M.; Butt, A. I.; Buttar, C. M.; Butterworth, J. M.; Butti, P.; Buttinger, W.; Buzatu, A.; Cabrera Urbán, S.; Caforio, D.; Cakir, O.; Calafiura, P.; Calandri, A.; Calderini, G.; Calfayan, P.; Caloba, L. P.; Calvet, D.; Calvet, S.; Camacho Toro, R.; Camarda, S.; Cameron, D.; Caminada, L. M.; Caminal Armadans, R.; Campana, S.; Campanelli, M.; Campoverde, A.; Canale, V.; Canepa, A.; Cano Bret, M.; Cantero, J.; Cantrill, R.; Cao, T.; Capeans Garrido, M. D. M.; Caprini, I.; Caprini, M.; Capua, M.; Caputo, R.; Cardarelli, R.; Carli, T.; Carlino, G.; Carminati, L.; Caron, S.; Carquin, E.; Carrillo-Montoya, G. D.; Carter, J. R.; Carvalho, J.; Casadei, D.; Casado, M. P.; Casolino, M.; Castaneda-Miranda, E.; Castelli, A.; Castillo Gimenez, V.; Castro, N. F.; Catastini, P.; Catinaccio, A.; Catmore, J. R.; Cattai, A.; Cattani, G.; Caudron, J.; Cavaliere, V.; Cavalli, D.; Cavalli-Sforza, M.; Cavasinni, V.; Ceradini, F.; Cerio, B. C.; Cerny, K.; Cerqueira, A. S.; Cerri, A.; Cerrito, L.; Cerutti, F.; Cerv, M.; Cervelli, A.; Cetin, S. A.; Chafaq, A.; Chakraborty, D.; Chalupkova, I.; Chang, P.; Chapleau, B.; Chapman, J. D.; Charfeddine, D.; Charlton, D. G.; Chau, C. C.; Chavez Barajas, C. A.; Cheatham, S.; Chegwidden, A.; Chekanov, S.; Chekulaev, S. V.; Chelkov, G. A.; Chelstowska, M. A.; Chen, C.; Chen, H.; Chen, K.; Chen, L.; Chen, S.; Chen, X.; Chen, Y.; Cheng, H. C.; Cheng, Y.; Cheplakov, A.; Cheremushkina, E.; Cherkaoui El Moursli, R.; Chernyatin, V.; Cheu, E.; Chevalier, L.; Chiarella, V.; Childers, J. T.; Chilingarov, A.; Chiodini, G.; Chisholm, A. S.; Chislett, R. T.; Chitan, A.; Chizhov, M. V.; Choi, K.; Chouridou, S.; Chow, B. K. B.; Chromek-Burckhart, D.; Chu, M. L.; Chudoba, J.; Chwastowski, J. J.; Chytka, L.; Ciapetti, G.; Ciftci, A. K.; Cinca, D.; Cindro, V.; Ciocio, A.; Citron, Z. H.; Ciubancan, M.; Clark, A.; Clark, P. J.; Clarke, R. N.; Cleland, W.; Clement, C.; Coadou, Y.; Cobal, M.; Coccaro, A.; Cochran, J.; Coffey, L.; Cogan, J. G.; Cole, B.; Cole, S.; Colijn, A. P.; Collot, J.; Colombo, T.; Compostella, G.; Conde Muiño, P.; Coniavitis, E.; Connell, S. H.; Connelly, I. A.; Consonni, S. M.; Consorti, V.; Constantinescu, S.; Conta, C.; Conti, G.; Conventi, F.; Cooke, M.; Cooper, B. D.; Cooper-Sarkar, A. M.; Copic, K.; Cornelissen, T.; Corradi, M.; Corriveau, F.; Corso-Radu, A.; Cortes-Gonzalez, A.; Cortiana, G.; Costa, G.; Costa, M. J.; Costanzo, D.; Côté, D.; Cottin, G.; Cowan, G.; Cox, B. E.; Cranmer, K.; Cree, G.; Crépé-Renaudin, S.; Crescioli, F.; Cribbs, W. A.; Crispin Ortuzar, M.; Cristinziani, M.; Croft, V.; Crosetti, G.; Cuhadar Donszelmann, T.; Cummings, J.; Curatolo, M.; Cuthbert, C.; Czirr, H.; Czodrowski, P.; D'Auria, S.; D'Onofrio, M.; Da Cunha Sargedas De Sousa, M. J.; Da Via, C.; Dabrowski, W.; Dafinca, A.; Dai, T.; Dale, O.; Dallaire, F.; Dallapiccola, C.; Dam, M.; Dandoy, J. R.; Daniells, A. C.; Danninger, M.; Dano Hoffmann, M.; Dao, V.; Darbo, G.; Darmora, S.; Dassoulas, J.; Dattagupta, A.; Davey, W.; David, C.; Davidek, T.; Davies, E.; Davies, M.; Davignon, O.; Davison, P.; Davygora, Y.; Dawe, E.; Dawson, I.; Daya-Ishmukhametova, R. K.; De, K.; de Asmundis, R.; De Castro, S.; De Cecco, S.; De Groot, N.; de Jong, P.; De la Torre, H.; De Lorenzi, F.; De Nooij, L.; De Pedis, D.; De Salvo, A.; De Sanctis, U.; De Santo, A.; De Vivie De Regie, J. B.; Dearnaley, W. J.; Debbe, R.; Debenedetti, C.; Dedovich, D. V.; Deigaard, I.; Del Peso, J.; Del Prete, T.; Delgove, D.; Deliot, F.; Delitzsch, C. M.; Deliyergiyev, M.; Dell'Acqua, A.; Dell'Asta, L.; Dell'Orso, M.; Della Pietra, M.; della Volpe, D.; Delmastro, M.; Delsart, P. A.; Deluca, C.; DeMarco, D. A.; Demers, S.; Demichev, M.; Demilly, A.; Denisov, S. P.; Derendarz, D.; Derkaoui, J. E.; Derue, F.; Dervan, P.; Desch, K.; Deterre, C.; Deviveiros, P. O.; Dewhurst, A.; Dhaliwal, S.; Di Ciaccio, A.; Di Ciaccio, L.; Di Domenico, A.; Di Donato, C.; Di Girolamo, A.; Di Girolamo, B.; Di Mattia, A.; Di Micco, B.; Di Nardo, R.; Di Simone, A.; Di Sipio, R.; Di Valentino, D.; Diaconu, C.; Diamond, M.; Dias, F. A.; Diaz, M. A.; Diehl, E. B.; Dietrich, J.; Dietzsch, T. A.; Diglio, S.; Dimitrievska, A.; Dingfelder, J.; Dita, P.; Dita, S.; Dittus, F.; Djama, F.; Djobava, T.; Djuvsland, J. I.; do Vale, M. A. B.; Dobos, D.; Dobre, M.; Doglioni, C.; Doherty, T.; Dohmae, T.; Dolejsi, J.; Dolezal, Z.; Dolgoshein, B. A.; Donadelli, M.; Donati, S.; Dondero, P.; Donini, J.; Dopke, J.; Doria, A.; Dova, M. T.; Doyle, A. T.; Dris, M.; Dubreuil, E.; Duchovni, E.; Duckeck, G.; Ducu, O. A.; Duda, D.; Dudarev, A.; Duflot, L.; Duguid, L.; Dührssen, M.; Dunford, M.; Duran Yildiz, H.; Düren, M.; Durglishvili, A.; Duschinger, D.; Dwuznik, M.; Dyndal, M.; Ecker, K. M.; Edson, W.; Edwards, N. C.; Ehrenfeld, W.; Eifert, T.; Eigen, G.; Einsweiler, K.; Ekelof, T.; El Kacimi, M.; Ellert, M.; Elles, S.; Ellinghaus, F.; Elliot, A. A.; Ellis, N.; Elmsheuser, J.; Elsing, M.; Emeliyanov, D.; Enari, Y.; Endner, O. C.; Endo, M.; Erdmann, J.; Ereditato, A.; Eriksson, D.; Ernis, G.; Ernst, J.; Ernst, M.; Errede, S.; Ertel, E.; Escalier, M.; Esch, H.; Escobar, C.; Esposito, B.; Etienvre, A. I.; Etzion, E.; Evans, H.; Ezhilov, A.; Fabbri, L.; Facini, G.; Fakhrutdinov, R. M.; Falciano, S.; Falla, R. J.; Faltova, J.; Fang, Y.; Fanti, M.; Farbin, A.; Farilla, A.; Farooque, T.; Farrell, S.; Farrington, S. M.; Farthouat, P.; Fassi, F.; Fassnacht, P.; Fassouliotis, D.; Favareto, A.; Fayard, L.; Federic, P.; Fedin, O. L.; Fedorko, W.; Feigl, S.; Feligioni, L.; Feng, C.; Feng, E. J.; Feng, H.; Fenyuk, A. B.; Fernandez Martinez, P.; Fernandez Perez, S.; Ferrag, S.; Ferrando, J.; Ferrari, A.; Ferrari, P.; Ferrari, R.; Ferreira de Lima, D. E.; Ferrer, A.; Ferrere, D.; Ferretti, C.; Ferretto Parodi, A.; Fiascaris, M.; Fiedler, F.; Filipčič, A.; Filipuzzi, M.; Filthaut, F.; Fincke-Keeler, M.; Finelli, K. D.; Fiolhais, M. C. N.; Fiorini, L.; Firan, A.; Fischer, A.; Fischer, C.; Fischer, J.; Fisher, W. C.; Fitzgerald, E. A.; Flechl, M.; Fleck, I.; Fleischmann, P.; Fleischmann, S.; Fletcher, G. T.; Fletcher, G.; Flick, T.; Floderus, A.; Flores Castillo, L. R.; Flowerdew, M. J.; Formica, A.; Forti, A.; Fournier, D.; Fox, H.; Fracchia, S.; Francavilla, P.; Franchini, M.; Francis, D.; Franconi, L.; Franklin, M.; Fraternali, M.; Freeborn, D.; French, S. T.; Friedrich, F.; Froidevaux, D.; Frost, J. A.; Fukunaga, C.; Fullana Torregrosa, E.; Fulsom, B. G.; Fuster, J.; Gabaldon, C.; Gabizon, O.; Gabrielli, A.; Gabrielli, A.; Gadatsch, S.; Gadomski, S.; Gagliardi, G.; Gagnon, P.; Galea, C.; Galhardo, B.; Gallas, E. J.; Gallop, B. J.; Gallus, P.; Galster, G.; Gan, K. K.; Gao, J.; Gao, Y. S.; Garay Walls, F. M.; Garberson, F.; García, C.; García Navarro, J. E.; Garcia-Sciveres, M.; Gardner, R. W.; Garelli, N.; Garonne, V.; Gatti, C.; Gaudio, G.; Gaur, B.; Gauthier, L.; Gauzzi, P.; Gavrilenko, I. L.; Gay, C.; Gaycken, G.; Gazis, E. N.; Ge, P.; Gecse, Z.; Gee, C. N. P.; Geerts, D. A. A.; Geich-Gimbel, Ch.; Gemme, C.; Genest, M. H.; Gentile, S.; George, M.; George, S.; Gerbaudo, D.; Gershon, A.; Ghazlane, H.; Ghodbane, N.; Giacobbe, B.; Giagu, S.; Giangiobbe, V.; Giannetti, P.; Gianotti, F.; Gibbard, B.; Gibson, S. M.; Gilchriese, M.; Gillam, T. P. S.; Gillberg, D.; Gilles, G.; Gingrich, D. M.; Giokaris, N.; Giordani, M. P.; Giorgi, F. M.; Giorgi, F. M.; Giraud, P. F.; Giugni, D.; Giuliani, C.; Giulini, M.; Gjelsten, B. K.; Gkaitatzis, S.; Gkialas, I.; Gkougkousis, E. L.; Gladilin, L. K.; Glasman, C.; Glatzer, J.; Glaysher, P. C. F.; Glazov, A.; Goblirsch-Kolb, M.; Goddard, J. R.; Godlewski, J.; Goldfarb, S.; Golling, T.; Golubkov, D.; Gomes, A.; Gonçalo, R.; Goncalves Pinto Firmino Da Costa, J.; Gonella, L.; González de la Hoz, S.; Gonzalez Parra, G.; Gonzalez-Sevilla, S.; Goossens, L.; Gorbounov, P. A.; Gordon, H. A.; Gorelov, I.; Gorini, B.; Gorini, E.; Gorišek, A.; Gornicki, E.; Goshaw, A. T.; Gössling, C.; Gostkin, M. I.; Gouighri, M.; Goujdami, D.; Goussiou, A. G.; Grabas, H. M. X.; Graber, L.; Grabowska-Bold, I.; Grafström, P.; Grahn, K.-J.; Gramling, J.; Gramstad, E.; Grancagnolo, S.; Grassi, V.; Gratchev, V.; Gray, H. M.; Graziani, E.; Greenwood, Z. D.; Gregersen, K.; Gregor, I. M.; Grenier, P.; Griffiths, J.; Grillo, A. A.; Grimm, K.; Grinstein, S.; Gris, Ph.; Grivaz, J.-F.; Grohs, J. P.; Grohsjean, A.; Gross, E.; Grosse-Knetter, J.; Grossi, G. C.; Grout, Z. J.; Guan, L.; Guenther, J.; Guescini, F.; Guest, D.; Gueta, O.; Guido, E.; Guillemin, T.; Guindon, S.; Gul, U.; Gumpert, C.; Guo, J.; Gupta, S.; Gutierrez, P.; Gutierrez Ortiz, N. G.; Gutschow, C.; Guttman, N.; Guyot, C.; Gwenlan, C.; Gwilliam, C. B.; Haas, A.; Haber, C.; Hadavand, H. K.; Haddad, N.; Haefner, P.; Hageböck, S.; Hajduk, Z.; Hakobyan, H.; Haleem, M.; Haley, J.; Hall, D.; Halladjian, G.; Hallewell, G. D.; Hamacher, K.; Hamal, P.; Hamano, K.; Hamer, M.; Hamilton, A.; Hamilton, S.; Hamity, G. N.; Hamnett, P. G.; Han, L.; Hanagaki, K.; Hanawa, K.; Hance, M.; Hanke, P.; Hanna, R.; Hansen, J. B.; Hansen, J. D.; Hansen, P. H.; Hara, K.; Hard, A. S.; Harenberg, T.; Hariri, F.; Harkusha, S.; Harrington, R. D.; Harrison, P. F.; Hartjes, F.; Hasegawa, M.; Hasegawa, S.; Hasegawa, Y.; Hasib, A.; Hassani, S.; Haug, S.; Hauser, R.; Hauswald, L.; Havranek, M.; Hawkes, C. M.; Hawkings, R. J.; Hawkins, A. D.; Hayashi, T.; Hayden, D.; Hays, C. P.; Hays, J. M.; Hayward, H. S.; Haywood, S. J.; Head, S. J.; Heck, T.; Hedberg, V.; Heelan, L.; Heim, S.; Heim, T.; Heinemann, B.; Heinrich, L.; Hejbal, J.; Helary, L.; Heller, M.; Hellman, S.; Hellmich, D.; Helsens, C.; Henderson, J.; Henderson, R. C. W.; Heng, Y.; Hengler, C.; Henrichs, A.; Henriques Correia, A. M.; Henrot-Versille, S.; Herbert, G. H.; Hernández Jiménez, Y.; Herrberg-Schubert, R.; Herten, G.; Hertenberger, R.; Hervas, L.; Hesketh, G. G.; Hessey, N. P.; Hickling, R.; Higón-Rodriguez, E.; Hill, E.; Hill, J. C.; Hiller, K. H.; Hillier, S. J.; Hinchliffe, I.; Hines, E.; Hinman, R. R.; Hirose, M.; Hirschbuehl, D.; Hobbs, J.; Hod, N.; Hodgkinson, M. C.; Hodgson, P.; Hoecker, A.; Hoeferkamp, M. R.; Hoenig, F.; Hohlfeld, M.; Holmes, T. R.; Hong, T. M.; Hooft van Huysduynen, L.; Hopkins, W. H.; Horii, Y.; Horton, A. J.; Hostachy, J.-Y.; Hou, S.; Hoummada, A.; Howard, J.; Howarth, J.; Hrabovsky, M.; Hristova, I.; Hrivnac, J.; Hryn'ova, T.; Hrynevich, A.; Hsu, C.; Hsu, P. J.; Hsu, S.-C.; Hu, D.; Hu, Q.; Hu, X.; Huang, Y.; Hubacek, Z.; Hubaut, F.; Huegging, F.; Huffman, T. B.; Hughes, E. W.; Hughes, G.; Huhtinen, M.; Hülsing, T. A.; Huseynov, N.; Huston, J.; Huth, J.; Iacobucci, G.; Iakovidis, G.; Ibragimov, I.; Iconomidou-Fayard, L.; Ideal, E.; Idrissi, Z.; Iengo, P.; Igonkina, O.; Iizawa, T.; Ikegami, Y.; Ikematsu, K.; Ikeno, M.; Ilchenko, Y.; Iliadis, D.; Ilic, N.; Inamaru, Y.; Ince, T.; Ioannou, P.; Iodice, M.; Iordanidou, K.; Ippolito, V.; Irles Quiles, A.; Isaksson, C.; Ishino, M.; Ishitsuka, M.; Ishmukhametov, R.; Issever, C.; Istin, S.; Iturbe Ponce, J. M.; Iuppa, R.; Ivarsson, J.; Iwanski, W.; Iwasaki, H.; Izen, J. M.; Izzo, V.; Jabbar, S.; Jackson, B.; Jackson, M.; Jackson, P.; Jaekel, M. R.; Jain, V.; Jakobs, K.; Jakobsen, S.; Jakoubek, T.; Jakubek, J.; Jamin, D. O.; Jana, D. K.; Jansen, E.; Jansky, R. W.; Janssen, J.; Janus, M.; Jarlskog, G.; Javadov, N.; Javůrek, T.; Jeanty, L.; Jejelava, J.; Jeng, G.-Y.; Jennens, D.; Jenni, P.; Jentzsch, J.; Jeske, C.; Jézéquel, S.; Ji, H.; Jia, J.; Jiang, Y.; Jimenez Pena, J.; Jin, S.; Jinaru, A.; Jinnouchi, O.; Joergensen, M. D.; Johansson, P.; Johns, K. A.; Jon-And, K.; Jones, G.; Jones, R. W. L.; Jones, T. J.; Jongmanns, J.; Jorge, P. M.; Joshi, K. D.; Jovicevic, J.; Ju, X.; Jung, C. A.; Jussel, P.; Juste Rozas, A.; Kaci, M.; Kaczmarska, A.; Kado, M.; Kagan, H.; Kagan, M.; Kahn, S. J.; Kajomovitz, E.; Kalderon, C. W.; Kama, S.; Kamenshchikov, A.; Kanaya, N.; Kaneda, M.; Kaneti, S.; Kantserov, V. A.; Kanzaki, J.; Kaplan, B.; Kapliy, A.; Kar, D.; Karakostas, K.; Karamaoun, A.; Karastathis, N.; Kareem, M. J.; Karnevskiy, M.; Karpov, S. N.; Karpova, Z. M.; Karthik, K.; Kartvelishvili, V.; Karyukhin, A. N.; Kashif, L.; Kass, R. D.; Kastanas, A.; Kataoka, Y.; Katre, A.; Katzy, J.; Kawagoe, K.; Kawamoto, T.; Kawamura, G.; Kazama, S.; Kazanin, V. F.; Kazarinov, M. Y.; Keeler, R.; Kehoe, R.; Keller, J. S.; Kempster, J. J.; Keoshkerian, H.; Kepka, O.; Kerševan, B. P.; Kersten, S.; Keyes, R. A.; Khalil-zada, F.; Khandanyan, H.; Khanov, A.; Kharlamov, A. G.; Khodinov, A.; Khomich, A.; Khoo, T. J.; Khovanskiy, V.; Khramov, E.; Khubua, J.; Kim, H. Y.; Kim, H.; Kim, S. H.; Kim, Y.; Kimura, N.; Kind, O. M.; King, B. T.; King, M.; King, R. S. B.; King, S. B.; Kirk, J.; Kiryunin, A. E.; Kishimoto, T.; Kisielewska, D.; Kiss, F.; Kiuchi, K.; Kladiva, E.; Klein, M. H.; Klein, M.; Klein, U.; Kleinknecht, K.; Klimek, P.; Klimentov, A.; Klingenberg, R.; Klinger, J. A.; Klioutchnikova, T.; Klok, P. F.; Kluge, E.-E.; Kluit, P.; Kluth, S.; Kneringer, E.; Knoops, E. B. F. G.; Knue, A.; Kobayashi, D.; Kobayashi, T.; Kobel, M.; Kocian, M.; Kodys, P.; Koffas, T.; Koffeman, E.; Kogan, L. A.; Kohlmann, S.; Kohout, Z.; Kohriki, T.; Koi, T.; Kolanoski, H.; Koletsou, I.; Komar, A. A.; Komori, Y.; Kondo, T.; Kondrashova, N.; Köneke, K.; König, A. C.; König, S.; Kono, T.; Konoplich, R.; Konstantinidis, N.; Kopeliansky, R.; Koperny, S.; Köpke, L.; Kopp, A. K.; Korcyl, K.; Kordas, K.; Korn, A.; Korol, A. A.; Korolkov, I.; Korolkova, E. V.; Kortner, O.; Kortner, S.; Kosek, T.; Kostyukhin, V. V.; Kotov, V. M.; Kotwal, A.; Kourkoumeli-Charalampidi, A.; Kourkoumelis, C.; Kouskoura, V.; Koutsman, A.; Kowalewski, R.; Kowalski, T. Z.; Kozanecki, W.; Kozhin, A. S.; Kramarenko, V. A.; Kramberger, G.; Krasnopevtsev, D.; Krasny, M. W.; Krasznahorkay, A.; Kraus, J. K.; Kravchenko, A.; Kreiss, S.; Kretz, M.; Kretzschmar, J.; Kreutzfeldt, K.; Krieger, P.; Krizka, K.; Kroeninger, K.; Kroha, H.; Kroll, J.; Kroseberg, J.; Krstic, J.; Kruchonak, U.; Krüger, H.; Krumnack, N.; Krumshteyn, Z. V.; Kruse, A.; Kruse, M. C.; Kruskal, M.; Kubota, T.; Kucuk, H.; Kuday, S.; Kuehn, S.; Kugel, A.; Kuger, F.; Kuhl, A.; Kuhl, T.; Kukhtin, V.; Kulchitsky, Y.; Kuleshov, S.; Kuna, M.; Kunigo, T.; Kupco, A.; Kurashige, H.; Kurochkin, Y. A.; Kurumida, R.; Kus, V.; Kuwertz, E. S.; Kuze, M.; Kvita, J.; Kwan, T.; Kyriazopoulos, D.; La Rosa, A.; La Rosa Navarro, J. L.; La Rotonda, L.; Lacasta, C.; Lacava, F.; Lacey, J.; Lacker, H.; Lacour, D.; Lacuesta, V. R.; Ladygin, E.; Lafaye, R.; Laforge, B.; Lagouri, T.; Lai, S.; Lambourne, L.; Lammers, S.; Lampen, C. L.; Lampl, W.; Lançon, E.; Landgraf, U.; Landon, M. P. J.; Lang, V. S.; Lankford, A. J.; Lanni, F.; Lantzsch, K.; Laplace, S.; Lapoire, C.; Laporte, J. F.; Lari, T.; Lasagni Manghi, F.; Lassnig, M.; Laurelli, P.; Lavrijsen, W.; Law, A. T.; Laycock, P.; Le Dortz, O.; Le Guirriec, E.; Le Menedeu, E.; LeCompte, T.; Ledroit-Guillon, F.; Lee, C. A.; Lee, S. C.; Lee, L.; Lefebvre, G.; Lefebvre, M.; Legger, F.; Leggett, C.; Lehan, A.; Lehmann Miotto, G.; Lei, X.; Leight, W. A.; Leisos, A.; Leister, A. G.; Leite, M. A. L.; Leitner, R.; Lellouch, D.; Lemmer, B.; Leney, K. J. C.; Lenz, T.; Lenzi, B.; Leone, R.; Leone, S.; Leonidopoulos, C.; Leontsinis, S.; Leroy, C.; Lester, C. G.; Levchenko, M.; Levêque, J.; Levin, D.; Levinson, L. J.; Levy, M.; Lewis, A.; Leyko, A. M.; Leyton, M.; Li, B.; Li, B.; Li, H.; Li, H. L.; Li, L.; Li, L.; Li, S.; Li, Y.; Liang, Z.; Liao, H.; Liberti, B.; Lichard, P.; Lie, K.; Liebal, J.; Liebig, W.; Limbach, C.; Limosani, A.; Lin, S. C.; Lin, T. H.; Linde, F.; Lindquist, B. E.; Linnemann, J. T.; Lipeles, E.; Lipniacka, A.; Lisovyi, M.; Liss, T. M.; Lissauer, D.; Lister, A.; Litke, A. M.; Liu, B.; Liu, D.; Liu, J.; Liu, J. B.; Liu, K.; Liu, L.; Liu, M.; Liu, M.; Liu, Y.; Livan, M.; Lleres, A.; Llorente Merino, J.; Lloyd, S. L.; Lo Sterzo, F.; Lobodzinska, E.; Loch, P.; Lockman, W. S.; Loebinger, F. K.; Loevschall-Jensen, A. E.; Loginov, A.; Lohse, T.; Lohwasser, K.; Lokajicek, M.; Long, B. A.; Long, J. D.; Long, R. E.; Looper, K. A.; Lopes, L.; Lopez Mateos, D.; Lopez Paredes, B.; Lopez Paz, I.; Lorenz, J.; Lorenzo Martinez, N.; Losada, M.; Loscutoff, P.; Lösel, P. J.; Lou, X.; Lounis, A.; Love, J.; Love, P. A.; Lu, N.; Lubatti, H. J.; Luci, C.; Lucotte, A.; Luehring, F.; Lukas, W.; Luminari, L.; Lundberg, O.; Lund-Jensen, B.; Lungwitz, M.; Lynn, D.; Lysak, R.; Lytken, E.; Ma, H.; Ma, L. L.; Maccarrone, G.; Macchiolo, A.; Macdonald, C. M.; Machado Miguens, J.; Macina, D.; Madaffari, D.; Madar, R.; Maddocks, H. J.; Mader, W. F.; Madsen, A.; Maeno, T.; Maevskiy, A.; Magradze, E.; Mahboubi, K.; Mahlstedt, J.; Mahmoud, S.; Maiani, C.; Maidantchik, C.; Maier, A. A.; Maier, T.; Maio, A.; Majewski, S.; Makida, Y.; Makovec, N.; Malaescu, B.; Malecki, Pa.; Maleev, V. P.; Malek, F.; Mallik, U.; Malon, D.; Malone, C.; Maltezos, S.; Malyshev, V. M.; Malyukov, S.; Mamuzic, J.; Mancini, G.; Mandelli, B.; Mandelli, L.; Mandić, I.; Mandrysch, R.; Maneira, J.; Manfredini, A.; Manhaes de Andrade Filho, L.; Manjarres Ramos, J.; Mann, A.; Manning, P. M.; Manousakis-Katsikakis, A.; Mansoulie, B.; Mantifel, R.; Mantoani, M.; Mapelli, L.; March, L.; Marchiori, G.; Marcisovsky, M.; Marino, C. P.; Marjanovic, M.; Marroquim, F.; Marsden, S. P.; Marshall, Z.; Marti, L. F.; Marti-Garcia, S.; Martin, B.; Martin, T. A.; Martin, V. J.; Martin dit Latour, B.; Martinez, H.; Martinez, M.; Martin-Haugh, S.; Martoiu, V. S.; Martyniuk, A. C.; Marx, M.; Marzano, F.; Marzin, A.; Masetti, L.; Mashimo, T.; Mashinistov, R.; Masik, J.; Maslennikov, A. L.; Massa, I.; Massa, L.; Massol, N.; Mastrandrea, P.; Mastroberardino, A.; Masubuchi, T.; Mättig, P.; Mattmann, J.; Maurer, J.; Maxfield, S. J.; Maximov, D. A.; Mazini, R.; Mazza, S. M.; Mazzaferro, L.; Mc Goldrick, G.; Mc Kee, S. P.; McCarn, A.; McCarthy, R. L.; McCarthy, T. G.; McCubbin, N. A.; McFarlane, K. W.; Mcfayden, J. A.; Mchedlidze, G.; McMahon, S. J.; McPherson, R. A.; Mechnich, J.; Medinnis, M.; Meehan, S.; Mehlhase, S.; Mehta, A.; Meier, K.; Meineck, C.; Meirose, B.; Melachrinos, C.; Mellado Garcia, B. R.; Meloni, F.; Mengarelli, A.; Menke, S.; Meoni, E.; Mercurio, K. M.; Mergelmeyer, S.; Meric, N.; Mermod, P.; Merola, L.; Meroni, C.; Merritt, F. S.; Merritt, H.; Messina, A.; Metcalfe, J.; Mete, A. S.; Meyer, C.; Meyer, C.; Meyer, J.-P.; Meyer, J.; Middleton, R. P.; Migas, S.; Miglioranzi, S.; Mijović, L.; Mikenberg, G.; Mikestikova, M.; Mikuž, M.; Milic, A.; Miller, D. W.; Mills, C.; Milov, A.; Milstead, D. A.; Minaenko, A. A.; Minami, Y.; Minashvili, I. A.; Mincer, A. I.; Mindur, B.; Mineev, M.; Ming, Y.; Mir, L. M.; Mirabelli, G.; Mitani, T.; Mitrevski, J.; Mitsou, V. A.; Miucci, A.; Miyagawa, P. S.; Mjörnmark, J. U.; Moa, T.; Mochizuki, K.; Mohapatra, S.; Mohr, W.; Molander, S.; Moles-Valls, R.; Mönig, K.; Monini, C.; Monk, J.; Monnier, E.; Montejo Berlingen, J.; Monticelli, F.; Monzani, S.; Moore, R. W.; Morange, N.; Moreno, D.; Moreno Llácer, M.; Morettini, P.; Morgenstern, M.; Morii, M.; Morisbak, V.; Moritz, S.; Morley, A. K.; Mornacchi, G.; Morris, J. D.; Morton, A.; Morvaj, L.; Mosidze, M.; Moss, J.; Motohashi, K.; Mount, R.; Mountricha, E.; Mouraviev, S. V.; Moyse, E. J. W.; Muanza, S.; Mudd, R. D.; Mueller, F.; Mueller, J.; Mueller, K.; Mueller, R. S. P.; Mueller, T.; Muenstermann, D.; Mullen, P.; Munwes, Y.; Murillo Quijada, J. A.; Murray, W. J.; Musheghyan, H.; Musto, E.; Myagkov, A. G.; Myska, M.; Nackenhorst, O.; Nadal, J.; Nagai, K.; Nagai, R.; Nagai, Y.; Nagano, K.; Nagarkar, A.; Nagasaka, Y.; Nagata, K.; Nagel, M.; Nagy, E.; Nairz, A. M.; Nakahama, Y.; Nakamura, K.; Nakamura, T.; Nakano, I.; Namasivayam, H.; Nanava, G.; Naranjo Garcia, R. F.; Narayan, R.; Nattermann, T.; Naumann, T.; Navarro, G.; Nayyar, R.; Neal, H. A.; Nechaeva, P. Yu.; Neep, T. J.; Nef, P. D.; Negri, A.; Negrini, M.; Nektarijevic, S.; Nellist, C.; Nelson, A.; Nemecek, S.; Nemethy, P.; Nepomuceno, A. A.; Nessi, M.; Neubauer, M. S.; Neumann, M.; Neves, R. M.; Nevski, P.; Newman, P. R.; Nguyen, D. H.; Nickerson, R. B.; Nicolaidou, R.; Nicquevert, B.; Nielsen, J.; Nikiforou, N.; Nikiforov, A.; Nikolaenko, V.; Nikolic-Audit, I.; Nikolopoulos, K.; Nilsson, P.; Ninomiya, Y.; Nisati, A.; Nisius, R.; Nobe, T.; Nomachi, M.; Nomidis, I.; Nooney, T.; Norberg, S.; Nordberg, M.; Novgorodova, O.; Nowak, S.; Nozaki, M.; Nozka, L.; Ntekas, K.; Nunes Hanninger, G.; Nunnemann, T.; Nurse, E.; Nuti, F.; O'Brien, B. J.; O'grady, F.; O'Neil, D. C.; O'Shea, V.; Oakham, F. G.; Oberlack, H.; Obermann, T.; Ocariz, J.; Ochi, A.; Ochoa, I.; Oda, S.; Odaka, S.; Ogren, H.; Oh, A.; Oh, S. H.; Ohm, C. C.; Ohman, H.; Oide, H.; Okamura, W.; Okawa, H.; Okumura, Y.; Okuyama, T.; Olariu, A.; Olivares Pino, S. A.; Oliveira Damazio, D.; Oliver Garcia, E.; Olszewski, A.; Olszowska, J.; Onofre, A.; Onyisi, P. U. E.; Oram, C. J.; Oreglia, M. J.; Oren, Y.; Orestano, D.; Orlando, N.; Oropeza Barrera, C.; Orr, R. S.; Osculati, B.; Ospanov, R.; Otero y Garzon, G.; Otono, H.; Ouchrif, M.; Ouellette, E. A.; Ould-Saada, F.; Ouraou, A.; Oussoren, K. P.; Ouyang, Q.; Ovcharova, A.; Owen, M.; Owen, R. E.; Ozcan, V. E.; Ozturk, N.; Pachal, K.; Pacheco Pages, A.; Padilla Aranda, C.; Pagáčová, M.; Pagan Griso, S.; Paganis, E.; Pahl, C.; Paige, F.; Pais, P.; Pajchel, K.; Palacino, G.; Palestini, S.; Palka, M.; Pallin, D.; Palma, A.; Pan, Y. B.; Panagiotopoulou, E.; Pandini, C. E.; Panduro Vazquez, J. G.; Pani, P.; Panikashvili, N.; Panitkin, S.; Pantea, D.; Paolozzi, L.; Papadopoulou, Th. D.; Papageorgiou, K.; Paramonov, A.; Paredes Hernandez, D.; Parker, M. A.; Parker, K. A.; Parodi, F.; Parsons, J. A.; Parzefall, U.; Pasqualucci, E.; Passaggio, S.; Pastore, F.; Pastore, Fr.; Pásztor, G.; Pataraia, S.; Patel, N. D.; Pater, J. R.; Pauly, T.; Pearce, J.; Pearson, B.; Pedersen, L. E.; Pedersen, M.; Pedraza Lopez, S.; Pedro, R.; Peleganchuk, S. V.; Pelikan, D.; Peng, H.; Penning, B.; Penwell, J.; Perepelitsa, D. V.; Perez Codina, E.; Pérez García-Estañ, M. T.; Perini, L.; Pernegger, H.; Perrella, S.; Peschke, R.; Peshekhonov, V. D.; Peters, K.; Peters, R. F. Y.; Petersen, B. A.; Petersen, T. C.; Petit, E.; Petridis, A.; Petridou, C.; Petrolo, E.; Petrucci, F.; Pettersson, N. E.; Pezoa, R.; Phillips, P. W.; Piacquadio, G.; Pianori, E.; Picazio, A.; Piccaro, E.; Piccinini, M.; Pickering, M. A.; Piegaia, R.; Pignotti, D. T.; Pilcher, J. E.; Pilkington, A. D.; Pina, J.; Pinamonti, M.; Pinfold, J. L.; Pingel, A.; Pinto, B.; Pires, S.; Pitt, M.; Pizio, C.; Plazak, L.; Pleier, M.-A.; Pleskot, V.; Plotnikova, E.; Plucinski, P.; Pluth, D.; Poettgen, R.; Poggioli, L.; Pohl, D.; Polesello, G.; Policicchio, A.; Polifka, R.; Polini, A.; Pollard, C. S.; Polychronakos, V.; Pommès, K.; Pontecorvo, L.; Pope, B. G.; Popeneciu, G. A.; Popovic, D. S.; Poppleton, A.; Pospisil, S.; Potamianos, K.; Potrap, I. N.; Potter, C. J.; Potter, C. T.; Poulard, G.; Poveda, J.; Pozdnyakov, V.; Pralavorio, P.; Pranko, A.; Prasad, S.; Prell, S.; Price, D.; Price, J.; Price, L. E.; Primavera, M.; Prince, S.; Proissl, M.; Prokofiev, K.; Prokoshin, F.; Protopapadaki, E.; Protopopescu, S.; Proudfoot, J.; Przybycien, M.; Ptacek, E.; Puddu, D.; Pueschel, E.; Puldon, D.; Purohit, M.; Puzo, P.; Qian, J.; Qin, G.; Qin, Y.; Quadt, A.; Quarrie, D. R.; Quayle, W. B.; Queitsch-Maitland, M.; Quilty, D.; Qureshi, A.; Radeka, V.; Radescu, V.; Radhakrishnan, S. K.; Radloff, P.; Rados, P.; Ragusa, F.; Rahal, G.; Rajagopalan, S.; Rammensee, M.; Rangel-Smith, C.; Rauscher, F.; Rave, S.; Rave, T. C.; Ravenscroft, T.; Raymond, M.; Read, A. L.; Readioff, N. P.; Rebuzzi, D. M.; Redelbach, A.; Redlinger, G.; Reece, R.; Reeves, K.; Rehnisch, L.; Reisin, H.; Relich, M.; Rembser, C.; Ren, H.; Renaud, A.; Rescigno, M.; Resconi, S.; Rezanova, O. L.; Reznicek, P.; Rezvani, R.; Richter, R.; Richter-Was, E.; Ridel, M.; Rieck, P.; Riegel, C. J.; Rieger, J.; Rijssenbeek, M.; Rimoldi, A.; Rinaldi, L.; Ritsch, E.; Riu, I.; Rizatdinova, F.; Rizvi, E.; Robertson, S. H.; Robichaud-Veronneau, A.; Robinson, D.; Robinson, J. E. M.; Robson, A.; Roda, C.; Rodrigues, L.; Roe, S.; Røhne, O.; Rolli, S.; Romaniouk, A.; Romano, M.; Romano Saez, S. M.; Romero Adam, E.; Rompotis, N.; Ronzani, M.; Roos, L.; Ros, E.; Rosati, S.; Rosbach, K.; Rose, P.; Rosendahl, P. L.; Rosenthal, O.; Rossetti, V.; Rossi, E.; Rossi, L. P.; Rosten, R.; Rotaru, M.; Roth, I.; Rothberg, J.; Rousseau, D.; Royon, C. R.; Rozanov, A.; Rozen, Y.; Ruan, X.; Rubbo, F.; Rubinskiy, I.; Rud, V. I.; Rudolph, C.; Rudolph, M. S.; Rühr, F.; Ruiz-Martinez, A.; Rurikova, Z.; Rusakovich, N. A.; Ruschke, A.; Russell, H. L.; Rutherfoord, J. P.; Ruthmann, N.; Ryabov, Y. F.; Rybar, M.; Rybkin, G.; Ryder, N. C.; Saavedra, A. F.; Sabato, G.; Sacerdoti, S.; Saddique, A.; Sadrozinski, H. F.-W.; Sadykov, R.; Safai Tehrani, F.; Saimpert, M.; Sakamoto, H.; Sakurai, Y.; Salamanna, G.; Salamon, A.; Saleem, M.; Salek, D.; Sales De Bruin, P. H.; Salihagic, D.; Salnikov, A.; Salt, J.; Salvatore, D.; Salvatore, F.; Salvucci, A.; Salzburger, A.; Sampsonidis, D.; Sanchez, A.; Sánchez, J.; Sanchez Martinez, V.; Sandaker, H.; Sandbach, R. L.; Sander, H. G.; Sanders, M. P.; Sandhoff, M.; Sandoval, C.; Sandstroem, R.; Sankey, D. P. C.; Sansoni, A.; Santoni, C.; Santonico, R.; Santos, H.; Santoyo Castillo, I.; Sapp, K.; Sapronov, A.; Saraiva, J. G.; Sarrazin, B.; Sasaki, O.; Sasaki, Y.; Sato, K.; Sauvage, G.; Sauvan, E.; Savage, G.; Savard, P.; Sawyer, C.; Sawyer, L.; Saxon, D. H.; Saxon, J.; Sbarra, C.; Sbrizzi, A.; Scanlon, T.; Scannicchio, D. A.; Scarcella, M.; Scarfone, V.; Schaarschmidt, J.; Schacht, P.; Schaefer, D.; Schaefer, R.; Schaeffer, J.; Schaepe, S.; Schaetzel, S.; Schäfer, U.; Schaffer, A. C.; Schaile, D.; Schamberger, R. D.; Scharf, V.; Schegelsky, V. A.; Scheirich, D.; Schernau, M.; Schiavi, C.; Schillo, C.; Schioppa, M.; Schlenker, S.; Schmidt, E.; Schmieden, K.; Schmitt, C.; Schmitt, S.; Schmitt, S.; Schneider, B.; Schnellbach, Y. J.; Schnoor, U.; Schoeffel, L.; Schoening, A.; Schoenrock, B. D.; Schorlemmer, A. L. S.; Schott, M.; Schouten, D.; Schovancova, J.; Schramm, S.; Schreyer, M.; Schroeder, C.; Schuh, N.; Schultens, M. J.; Schultz-Coulon, H.-C.; Schulz, H.; Schumacher, M.; Schumm, B. A.; Schune, Ph.; Schwanenberger, C.; Schwartzman, A.; Schwarz, T. A.; Schwegler, Ph.; Schwemling, Ph.; Schwienhorst, R.; Schwindling, J.; Schwindt, T.; Schwoerer, M.; Sciacca, F. G.; Scifo, E.; Sciolla, G.; Scuri, F.; Scutti, F.; Searcy, J.; Sedov, G.; Sedykh, E.; Seema, P.; Seidel, S. C.; Seiden, A.; Seifert, F.; Seixas, J. M.; Sekhniaidze, G.; Sekula, S. J.; Selbach, K. E.; Seliverstov, D. M.; Semprini-Cesari, N.; Serfon, C.; Serin, L.; Serkin, L.; Serre, T.; Seuster, R.; Severini, H.; Sfiligoj, T.; Sforza, F.; Sfyrla, A.; Shabalina, E.; Shamim, M.; Shan, L. Y.; Shang, R.; Shank, J. T.; Shapiro, M.; Shatalov, P. B.; Shaw, K.; Shcherbakova, A.; Shehu, C. Y.; Sherwood, P.; Shi, L.; Shimizu, S.; Shimmin, C. O.; Shimojima, M.; Shiyakova, M.; Shmeleva, A.; Shoaleh Saadi, D.; Shochet, M. J.; Shojaii, S.; Shrestha, S.; Shulga, E.; Shupe, M. A.; Shushkevich, S.; Sicho, P.; Sidiropoulou, O.; Sidorov, D.; Sidoti, A.; Siegert, F.; Sijacki, Dj.; Silva, J.; Silver, Y.; Silverstein, D.; Silverstein, S. B.; Simak, V.; Simard, O.; Simic, Lj.; Simion, S.; Simioni, E.; Simmons, B.; Simon, D.; Simoniello, R.; Sinervo, P.; Sinev, N. B.; Siragusa, G.; Sircar, A.; Sisakyan, A. N.; Sivoklokov, S. Yu.; Sjölin, J.; Sjursen, T. B.; Skinner, M. B.; Skottowe, H. P.; Skubic, P.; Slater, M.; Slavicek, T.; Slawinska, M.; Sliwa, K.; Smakhtin, V.; Smart, B. H.; Smestad, L.; Smirnov, S. Yu.; Smirnov, Y.; Smirnova, L. N.; Smirnova, O.; Smith, K. M.; Smith, M. N. K.; Smizanska, M.; Smolek, K.; Snesarev, A. A.; Snidero, G.; Snyder, S.; Sobie, R.; Socher, F.; Soffer, A.; Soh, D. A.; Solans, C. A.; Solar, M.; Solc, J.; Soldatov, E. Yu.; Soldevila, U.; Solodkov, A. A.; Soloshenko, A.; Solovyanov, O. V.; Solovyev, V.; Sommer, P.; Song, H. Y.; Soni, N.; Sood, A.; Sopczak, A.; Sopko, B.; Sopko, V.; Sorin, V.; Sosa, D.; Sosebee, M.; Sotiropoulou, C. L.; Soualah, R.; Soueid, P.; Soukharev, A. M.; South, D.; Spagnolo, S.; Spanò, F.; Spearman, W. R.; Spettel, F.; Spighi, R.; Spigo, G.; Spiller, L. A.; Spousta, M.; Spreitzer, T.; St. Denis, R. D.; Staerz, S.; Stahlman, J.; Stamen, R.; Stamm, S.; Stanecka, E.; Stanescu, C.; Stanescu-Bellu, M.; Stanitzki, M. M.; Stapnes, S.; Starchenko, E. A.; Stark, J.; Staroba, P.; Starovoitov, P.; Staszewski, R.; Stavina, P.; Steinberg, P.; Stelzer, B.; Stelzer, H. J.; Stelzer-Chilton, O.; Stenzel, H.; Stern, S.; Stewart, G. A.; Stillings, J. A.; Stockton, M. C.; Stoebe, M.; Stoicea, G.; Stolte, P.; Stonjek, S.; Stradling, A. R.; Straessner, A.; Stramaglia, M. E.; Strandberg, J.; Strandberg, S.; Strandlie, A.; Strauss, E.; Strauss, M.; Strizenec, P.; Ströhmer, R.; Strom, D. M.; Stroynowski, R.; Strubig, A.; Stucci, S. A.; Stugu, B.; Styles, N. A.; Su, D.; Su, J.; Subramaniam, R.; Succurro, A.; Sugaya, Y.; Suhr, C.; Suk, M.; Sulin, V. V.; Sultansoy, S.; Sumida, T.; Sun, S.; Sun, X.; Sundermann, J. E.; Suruliz, K.; Susinno, G.; Sutton, M. R.; Suzuki, Y.; Svatos, M.; Swedish, S.; Swiatlowski, M.; Sykora, I.; Sykora, T.; Ta, D.; Taccini, C.; Tackmann, K.; Taenzer, J.; Taffard, A.; Tafirout, R.; Taiblum, N.; Takai, H.; Takashima, R.; Takeda, H.; Takeshita, T.; Takubo, Y.; Talby, M.; Talyshev, A. A.; Tam, J. Y. C.; Tan, K. G.; Tanaka, J.; Tanaka, R.; Tanaka, S.; Tanaka, S.; Tanasijczuk, A. J.; Tannenwald, B. B.; Tannoury, N.; Tapprogge, S.; Tarem, S.; Tarrade, F.; Tartarelli, G. F.; Tas, P.; Tasevsky, M.; Tashiro, T.; Tassi, E.; Tavares Delgado, A.; Tayalati, Y.; Taylor, F. E.; Taylor, G. N.; Taylor, W.; Teischinger, F. A.; Teixeira Dias Castanheira, M.; Teixeira-Dias, P.; Temming, K. K.; Ten Kate, H.; Teng, P. K.; Teoh, J. J.; Tepel, F.; Terada, S.; Terashi, K.; Terron, J.; Terzo, S.; Testa, M.; Teuscher, R. J.; Therhaag, J.; Theveneaux-Pelzer, T.; Thomas, J. P.; Thomas-Wilsker, J.; Thompson, E. N.; Thompson, P. D.; Thompson, R. J.; Thompson, A. S.; Thomsen, L. A.; Thomson, E.; Thomson, M.; Thong, W. M.; Thun, R. P.; Tian, F.; Tibbetts, M. J.; Ticse Torres, R. E.; Tikhomirov, V. O.; Tikhonov, Yu. A.; Timoshenko, S.; Tiouchichine, E.; Tipton, P.; Tisserant, S.; Todorov, T.; Todorova-Nova, S.; Tojo, J.; Tokár, S.; Tokushuku, K.; Tollefson, K.; Tolley, E.; Tomlinson, L.; Tomoto, M.; Tompkins, L.; Toms, K.; Torrence, E.; Torres, H.; Torró Pastor, E.; Toth, J.; Touchard, F.; Tovey, D. R.; Tran, H. L.; Trefzger, T.; Tremblet, L.; Tricoli, A.; Trigger, I. M.; Trincaz-Duvoid, S.; Tripiana, M. F.; Trischuk, W.; Trocmé, B.; Troncon, C.; Trottier-McDonald, M.; Trovatelli, M.; True, P.; Trzebinski, M.; Trzupek, A.; Tsarouchas, C.; Tseng, J. C.-L.; Tsiareshka, P. V.; Tsionou, D.; Tsipolitis, G.; Tsirintanis, N.; Tsiskaridze, S.; Tsiskaridze, V.; Tskhadadze, E. G.; Tsukerman, I. I.; Tsulaia, V.; Tsuno, S.; Tsybychev, D.; Tudorache, A.; Tudorache, V.; Tuna, A. N.; Tupputi, S. A.; Turchikhin, S.; Turecek, D.; Turra, R.; Turvey, A. J.; Tuts, P. M.; Tykhonov, A.; Tylmad, M.; Tyndel, M.; Ueda, I.; Ueno, R.; Ughetto, M.; Ugland, M.; Uhlenbrock, M.; Ukegawa, F.; Unal, G.; Undrus, A.; Unel, G.; Ungaro, F. C.; Unno, Y.; Unverdorben, C.; Urban, J.; Urquijo, P.; Urrejola, P.; Usai, G.; Usanova, A.; Vacavant, L.; Vacek, V.; Vachon, B.; Valencic, N.; Valentinetti, S.; Valero, A.; Valery, L.; Valkar, S.; Valladolid Gallego, E.; Vallecorsa, S.; Valls Ferrer, J. A.; Van Den Wollenberg, W.; Van Der Deijl, P. C.; van der Geer, R.; van der Graaf, H.; Van Der Leeuw, R.; van Eldik, N.; van Gemmeren, P.; Van Nieuwkoop, J.; van Vulpen, I.; van Woerden, M. C.; Vanadia, M.; Vandelli, W.; Vanguri, R.; Vaniachine, A.; Vannucci, F.; Vardanyan, G.; Vari, R.; Varnes, E. W.; Varol, T.; Varouchas, D.; Vartapetian, A.; Varvell, K. E.; Vazeille, F.; Vazquez Schroeder, T.; Veatch, J.; Veloso, F.; Velz, T.; Veneziano, S.; Ventura, A.; Ventura, D.; Venturi, M.; Venturi, N.; Venturini, A.; Vercesi, V.; Verducci, M.; Verkerke, W.; Vermeulen, J. C.; Vest, A.; Vetterli, M. C.; Viazlo, O.; Vichou, I.; Vickey, T.; Vickey Boeriu, O. E.; Viehhauser, G. H. A.; Viel, S.; Vigne, R.; Villa, M.; Villaplana Perez, M.; Vilucchi, E.; Vincter, M. G.; Vinogradov, V. B.; Virzi, J.; Vivarelli, I.; Vives Vaque, F.; Vlachos, S.; Vladoiu, D.; Vlasak, M.; Vogel, M.; Vokac, P.; Volpi, G.; Volpi, M.; von der Schmitt, H.; von Radziewski, H.; von Toerne, E.; Vorobel, V.; Vorobev, K.; Vos, M.; Voss, R.; Vossebeld, J. H.; Vranjes, N.; Vranjes Milosavljevic, M.; Vrba, V.; Vreeswijk, M.; Vuillermet, R.; Vukotic, I.; Vykydal, Z.; Wagner, P.; Wagner, W.; Wahlberg, H.; Wahrmund, S.; Wakabayashi, J.; Walder, J.; Walker, R.; Walkowiak, W.; Wang, C.; Wang, F.; Wang, H.; Wang, H.; Wang, J.; Wang, J.; Wang, K.; Wang, R.; Wang, S. M.; Wang, T.; Wang, X.; Wanotayaroj, C.; Warburton, A.; Ward, C. P.; Wardrope, D. R.; Warsinsky, M.; Washbrook, A.; Wasicki, C.; Watkins, P. M.; Watson, A. T.; Watson, I. J.; Watson, M. F.; Watts, G.; Watts, S.; Waugh, B. M.; Webb, S.; Weber, M. S.; Weber, S. W.; Webster, J. S.; Weidberg, A. R.; Weinert, B.; Weingarten, J.; Weiser, C.; Weits, H.; Wells, P. S.; Wenaus, T.; Wendland, D.; Wengler, T.; Wenig, S.; Wermes, N.; Werner, M.; Werner, P.; Wessels, M.; Wetter, J.; Whalen, K.; Wharton, A. M.; White, A.; White, M. J.; White, R.; White, S.; Whiteson, D.; Wicke, D.; Wickens, F. J.; Wiedenmann, W.; Wielers, M.; Wienemann, P.; Wiglesworth, C.; Wiik-Fuchs, L. A. M.; Wildauer, A.; Wilkens, H. G.; Williams, H. H.; Williams, S.; Willis, C.; Willocq, S.; Wilson, A.; Wilson, J. A.; Wingerter-Seez, I.; Winklmeier, F.; Winter, B. T.; Wittgen, M.; Wittkowski, J.; Wollstadt, S. J.; Wolter, M. W.; Wolters, H.; Wosiek, B. K.; Wotschack, J.; Woudstra, M. J.; Wozniak, K. W.; Wu, M.; Wu, M.; Wu, S. L.; Wu, X.; Wu, Y.; Wyatt, T. R.; Wynne, B. M.; Xella, S.; Xu, D.; Xu, L.; Yabsley, B.; Yacoob, S.; Yakabe, R.; Yamada, M.; Yamaguchi, Y.; Yamamoto, A.; Yamamoto, S.; Yamanaka, T.; Yamauchi, K.; Yamazaki, Y.; Yan, Z.; Yang, H.; Yang, H.; Yang, Y.; Yanush, S.; Yao, L.; Yao, W.-M.; Yasu, Y.; Yatsenko, E.; Yau Wong, K. H.; Ye, J.; Ye, S.; Yeletskikh, I.; Yen, A. L.; Yildirim, E.; Yorita, K.; Yoshida, R.; Yoshihara, K.; Young, C.; Young, C. J. S.; Youssef, S.; Yu, D. R.; Yu, J.; Yu, J. M.; Yu, J.; Yuan, L.; Yurkewicz, A.; Yusuff, I.; Zabinski, B.; Zaidan, R.; Zaitsev, A. M.; Zaman, A.; Zambito, S.; Zanello, L.; Zanzi, D.; Zeitnitz, C.; Zeman, M.; Zemla, A.; Zengel, K.; Zenin, O.; Ženiš, T.; Zerwas, D.; Zhang, D.; Zhang, F.; Zhang, J.; Zhang, L.; Zhang, R.; Zhang, X.; Zhang, Z.; Zhao, X.; Zhao, Y.; Zhao, Z.; Zhemchugov, A.; Zhong, J.; Zhou, B.; Zhou, C.; Zhou, L.; Zhou, L.; Zhou, N.; Zhu, C. G.; Zhu, H.; Zhu, J.; Zhu, Y.; Zhuang, X.; Zhukov, K.; Zibell, A.; Zieminska, D.; Zimine, N. I.; Zimmermann, C.; Zimmermann, R.; Zimmermann, S.; Zinonos, Z.; Zinser, M.; Ziolkowski, M.; Živković, L.; Zobernig, G.; Zoccoli, A.; zur Nedden, M.; Zurzolo, G.; Zwalinski, L.
2015-09-01
Charged-particle spectra obtained in Pb+Pb interactions at √{s_{NN}}=2.76 TeV and pp interactions at √{s_{NN}}=2.76 TeV with the ATLAS detector at the LHC are presented, using data with integrated luminosities of 0.15 nb-1 and 4.2 pb-1, respectively, in a wide transverse momentum (0 .5 < p T < 150 GeV) and pseudorapidity (| η| < 2) range. For Pb+Pb collisions, the spectra are presented as a function of collision centrality, which is determined by the response of the forward calorimeters located on both sides of the interaction point. The nuclear modification factors R AA and R CP are presented in detail as a function of centrality, p T and η. They show a distinct p T-dependence with a pronounced minimum at about 7 GeV. Above 60 GeV, R AA is consistent with a plateau at a centrality-dependent value, within the uncertainties. The value is 0 .55 ± 0 .01(stat .) ± 0 .04(syst .) in the most central collisions. The R AA distribution is consistent with flat | η| dependence over the whole transverse momentum range in all centrality classes. [Figure not available: see fulltext.
Wilson, Walter B.; Sander, Lane C.; Oña-Ruales, Jorge O.; Mössner, Stephanie G.; Sidisky, Leonard M.; Lee, Milton L.; Wise, Stephen A.
2017-01-01
Retention indices for 48 polycyclic aromatic sulfur heterocycles (PASHs) were determined using gas chromatography with three different stationary phases: a 50% phenyl phase, a 50% liquid crystalline dimethylpolysiloxane (LC-DMPS) phase, and an ionic liquid (IL) phase. Correlations between the retention behavior on the three stationary phases and PASH geometry (L/B and T, i.e., length-to-breadth ratio and thickness, respectively) were investigated for the following four isomer sets: (1) 4 three-ring molecular mass (MM) 184 Da PASHs, (2) 13 four-ring MM 234 Da PASHs, (3) 10 five-ring MM 258 Da PASHs, and (4) 20 five-ring MM 284 Da PASHs. Correlation coefficients for retention on the 50% LC-DMPS vs L/B ranged from r = 0.50 (MM 284 Da) to r = 0.77 (MM 234 Da). Correlation coefficients for retention on the IL phase vs L/B ranged from r = 0.31 (MM 234 Da) to r = 0.54 (MM 284 Da). Correlation coefficients for retention on the 50% phenyl vs L/B ranged from r = 0.14 (MM 258 Da) to r = 0.59 (MM 284 Da). Several correlation trends are discussed in detail for the retention behavior of PASH on the three stationary phases. PMID:28089272
Wilson, Walter B; Sander, Lane C; Oña-Ruales, Jorge O; Mössner, Stephanie G; Sidisky, Leonard M; Lee, Milton L; Wise, Stephen A
2017-02-17
Retention indices for 48 polycyclic aromatic sulfur heterocycles (PASHs) were determined using gas chromatography with three different stationary phases: a 50% phenyl phase, a 50% liquid crystalline dimethylpolysiloxane (LC-DMPS) phase, and an ionic liquid (IL) phase. Correlations between the retention behavior on the three stationary phases and PASH geometry (L/B and T, i.e., length-to-breadth ratio and thickness, respectively) were investigated for the following four isomer sets: (1) 4 three-ring molecular mass (MM) 184Da PASHs, (2) 13 four-ring MM 234Da PASHs, (3) 10 five-ring MM 258Da PASHs, and (4) 20 five-ring MM 284Da PASHs. Correlation coefficients for retention on the 50% LC-DMPS vs L/B ranged from r=0.50 (MM 284Da) to r=0.77 (MM 234Da). Correlation coefficients for retention on the IL phase vs L/B ranged from r=0.31 (MM 234Da) to r=0.54 (MM 284Da). Correlation coefficients for retention on the 50% phenyl vs L/B ranged from r=0.14 (MM 258Da) to r=0.59 (MM 284Da). Several correlation trends are discussed in detail for the retention behavior of PASH on the three stationary phases. Published by Elsevier B.V.
NASA Astrophysics Data System (ADS)
Greenwood, W. G.; Tang, K. T.
1987-03-01
The R-6, R-8, and R-10 terms in the long-range expansion for the hyperfine frequency shift are calculated for hydrogen in the presence of He, Ne, Ar, Kr, and Xe. The R-6 terms are based on the dipole oscillator strength sums. For helium, the R-8 and R-10 terms are based on quadrupole and octupole oscillator strength sums. For the heavier inert gases, the results for the R-8 and R-10 terms are obtained from the sum rules and the static polarizabilities. Upper bounds are also determined for the R-8 and R-10 terms.
Spatial and temporal interactions of sympatric mountain lions in Arizona
Nicholson, Kerry L.; Krausman, Paul R.; Munguia-Vega, Adrian; Culver, Melanie
2011-01-01
Spatial and temporal interactions among individual members of populations can have direct applications to habitat management of mountain lions (Puma concolor). Our objectives were to evaluate home range overlap and spatial/temporal use of overlap zones (OZ) of mountain lions in Arizona. We incorporated spatial data with genetic analyses to assess relatedness between mountain lions with overlapping home ranges. We recorded the space use patterns of 29 radio-collared mountain lions in Arizona from August 2005 to August 2008. We genotyped 28 mountain lions and estimated the degree of relatedness among individuals. For 26 pairs of temporally overlapping mountain lions, 18 overlapped spatially and temporally and eight had corresponding genetic information. Home range overlap ranged from 1.18% to 46.38% (x̄=2443, SE = 2.96). Male–male pairs were located within 1 km of each other on average, 0.04% of the time, whereas male–female pairs on average were 3.0%. Two male–male pairs exhibited symmetrical spatial avoidance and two symmetrical spatial attractions to the OZ. We observed simultaneous temporal attraction in three male–male pairs and four male–female pairs. Individuals from Tucson were slightly related to one another within the population (n = 13, mean R = 0.0373 ± 0.0151) whereas lions from Payson (n = 6, mean R = -0.0079 ± 0.0356) and Prescott (n = 9, mean R = -0.0242 ± 0.0452) were not as related. Overall, males were less related to other males (n = 20, mean R = -0.0495 ± 0.0161) than females were related to other females (n = 8, mean R = 0.0015 ± 0.0839). Genetic distance was positively correlated with geographic distance (r2 = 0.22, P = 0.001). Spatial requirements and interactions influence social behavior and can play a role in determining population density.
Climate patterns as predictors of amphibians species richness and indicators of potential stress
Battaglin, W.; Hay, L.; McCabe, G.; Nanjappa, P.; Gallant, Alisa L.
2005-01-01
Amphibians occupy a range of habitats throughout the world, but species richness is greatest in regions with moist, warm climates. We modeled the statistical relations of anuran and urodele species richness with mean annual climate for the conterminous United States, and compared the strength of these relations at national and regional levels. Model variables were calculated for county and subcounty mapping units, and included 40-year (1960-1999) annual mean and mean annual climate statistics, mapping unit average elevation, mapping unit land area, and estimates of anuran and urodele species richness. Climate data were derived from more than 7,500 first-order and cooperative meteorological stations and were interpolated to the mapping units using multiple linear regression models. Anuran and urodele species richness were calculated from the United States Geological Survey's Amphibian Research and Monitoring Initiative (ARMI) National Atlas for Amphibian Distributions. The national multivariate linear regression (MLR) model of anuran species richness had an adjusted coefficient of determination (R2) value of 0.64 and the national MLR model for urodele species richness had an R2 value of 0.45. Stratifying the United States by coarse-resolution ecological regions provided models for anUrans that ranged in R2 values from 0.15 to 0.78. Regional models for urodeles had R2 values. ranging from 0.27 to 0.74. In general, regional models for anurans were more strongly influenced by temperature variables, whereas precipitation variables had a larger influence on urodele models.
Martella, Andrea; Sijben, Huub; Rufer, Arne C; Grether, Uwe; Fingerle, Juergen; Ullmer, Christoph; Hartung, Thomas; IJzerman, Adriaan P; van der Stelt, Mario; Heitman, Laura H
2017-10-01
The endocannabinoid system, and in particular the cannabinoid type 2 receptor (CB2R), raised the interest of many medicinal chemistry programs for its therapeutic relevance in several (patho)physiologic processes. However, the physico-chemical properties of tool compounds for CB2R (e.g., the radioligand [ 3 H]CP55,940) are not optimal, despite the research efforts in developing effective drugs to target this system. At the same time, the importance of drug-target binding kinetics is growing since the kinetic binding profile of a ligand may provide important insights for the resulting in vivo efficacy. In this context we synthesized and characterized [ 3 H]RO6957022, a highly selective CB2R inverse agonist, as a radiolabeled tool compound. In equilibrium and kinetic binding experiments [ 3 H]RO6957022 showed high affinity for human CB2R with fast association ( k on ) and moderate dissociation ( k off ) kinetics. To demonstrate the robustness of [ 3 H]RO6957022 binding, affinity studies were carried out for a wide range of CB2R reference ligands, spanning the range of full, partial, and inverse agonists. Finally, we used [ 3 H]RO6957022 to study the kinetic binding profiles (i.e., k on and k off values) of selected synthetic and endogenous (i.e., 2-arachidonoylglycerol, anandamide, and noladin ether) CB2R ligands by competition association experiments. All tested ligands, and in particular the endocannabinoids, displayed distinct kinetic profiles, shedding more light on their mechanism of action and the importance of association rates in the determination of CB2R affinity. Altogether, this study shows that the use of a novel tool compound, i.e., [ 3 H]RO6957022, can support the development of novel ligands with a repertoire of kinetic binding profiles for CB2R. Copyright © 2017 by The American Society for Pharmacology and Experimental Therapeutics.
Zhang, Fan; Hu, Jing; Kelsey, Chris R; Yoo, David; Yin, Fang-Fang; Cai, Jing
2012-11-01
To evaluate the reproducibility of tumor motion probability distribution function (PDF) in stereotactic body radiation therapy (SBRT) of lung cancer using cine megavoltage (MV) images. Cine MV images of 20 patients acquired during three-dimensional conformal (6-11 beams) SBRT treatments were retrospectively analyzed to extract tumor motion trajectories. For each patient, tumor motion PDFs were generated per fraction (PDF(n)) using three selected "usable" beams. Patients without at least three usable beams were excluded from the study. Fractional PDF reproducibility (R(n)) was calculated as the Dice similarity coefficient between PDF(n) to a "ground-truth" PDF (PDF(g)), which was generated using the selected beams of all fractions. The mean of R(n), labeled as R(m), was calculated for each patient and correlated to the patient's mean tumor motion rang (A(m)). Change of R(m) during the course of SBRT treatments was also evaluated. Intra- and intersubject coefficient of variation (CV) of R(m) and A(m) were determined. Thirteen patients had at least three usable beams and were analyzed. The mean of R(m) was 0.87 (range, 0.84-0.95). The mean of A(m) was 3.18 mm (range, 0.46-7.80 mm). R(m) was found to decrease as A(m) increases following an equation of R(m) = 0.17e(-0.9Am) + 0.84. R(m) also decreased slightly throughout the course of treatments. Intersubject CV of R(m) (0.05) was comparable to intrasubject CV of R(m) (range, 0.02-0.09); intersubject CV of A(m) (0.73) was significantly greater than intrasubject CV of A(m) (range, 0.09-0.24). Tumor motion PDF can be determined using cine MV images acquired during the treatments. The reproducibility of lung tumor motion PDF decreased exponentially as the tumor motion range increased and decreased slightly throughout the course of the treatments. Copyright © 2012 Elsevier Inc. All rights reserved.
Zhang, Kai; Schaab, Matthew R; Southwood, Gavin; Tor, Elizabeth R; Aston, Linda S; Song, Wenlu; Eitzer, Brian; Majumdar, Sanghamitra; Lapainis, Theodore; Mai, Huy; Tran, Kevin; El-Demerdash, Aref; Vega, Victor; Cai, Yanxuan; Wong, Jon W; Krynitsky, Alexandra J; Begley, Timothy H
2017-08-23
A collaborative study was conducted to evaluate stable isotope dilution assay (SIDA) and LC-MS/MS for the simultaneous determination of aflatoxins B 1 , B 2 , G 1 , and G 2 ; deoxynivalenol; fumonisins B 1 , B 2 , and B 3 ; ochratoxin A; HT-2 toxin; T-2 toxin; and zearalenone in foods. Samples were fortified with 12 13 C uniformly labeled mycotoxins ( 13 C-IS) corresponding to the native mycotoxins and extracted with acetonitrile/water (50:50 v/v), followed by centrifugation, filtration, and LC-MS/MS analysis. In addition to certified reference materials, the six participating laboratories analyzed corn, peanut butter, and wheat flour fortified with the 12 mycotoxins at concentrations ranging from 1.0 to 1000 ng/g. Using their available LC-MS/MS platform, each laboratory developed in-house instrumental conditions for analysis. The majority of recoveries ranged from 80 to 120% with relative standard derivations (RSDs) <20%. Greater than 90% of the average recoveries of the participating laboratories were in the range of 90-110%, with repeatability RSD r (within laboratory) < 10% and reproducibility RSD R (among laboratory) < 15%. All Z scores of the results of certified reference materials were between -2 and 2. Using 13 C-IS eliminated the need for matrix-matched calibration standards for quantitation, simplified sample preparation, and achieved simultaneous identification and quantitation of multiple mycotoxins in a simple LC-MS/MS procedure.
Coronal Magnetic Field Measurement from EUV Images Made by the Solar Dynamics Observatory
NASA Technical Reports Server (NTRS)
Gopalswamy, Natchimuthuk; Nitta, Nariaki; Akiyama, Sachiko; Makela, Pertti; Yashiro, Seiji
2012-01-01
By measuring the geometrical properties of the coronal mass ejection (CME) flux rope and the leading shock observed on 2010 June 13 by the Solar Dynamics Observatory (SDO) mission's Atmospheric Imaging Assembly we determine the Alfven speed and the magnetic field strength in the inner corona at a heliocentric distance of approx. 1.4 Rs The basic measurements are the shock standoff distance (Delta R) ahead of the CME flux rope, the radius of curvature of the flux rope (R(sub c)), and the shock speed. We first derive the Alfvenic Mach number (M) using the relationship, Delta R/R(sub c) = 0.81[(gamma-1) M(exp 2) + 2] / [(gamma +1)(M2 - 1)], where gamma is the only parameter that needed to be assumed. For gamma = 4/3, the Mach number declined from 3.7 to 1.5 indicating shock weakening within the field of view of the imager. The shock formation coincided with the appearance of a type II radio burst at a frequency of approx. 300 MHz (harmonic component), providing an independent confirmation of the shock. The shock compression ratio derived from the radio dynamic spectrum was found to be consistent with that derived from the theory of fast-mode MHD shocks. From the measured shock speed and the derived Mach number, we found the Alfven speed to increase from approx 140 km/s to 460 km/s over the distance range 1.2-1.5 Rs. By deriving the upstream plasma density from the emission frequency of the associated type II radio burst, we determined the coronal magnetic field to be in the range 1.3-1.5 G. The derived magnetic field values are consistent with other estimates in a similar distance range. This work demonstrates that the EUV imagers, in the presence of radio dynamic spectra, can be used as coronal magnetometers
Promyelocytic Leukemia Protein Is a Cell-Intrinsic Factor Inhibiting Parvovirus DNA Replication
Mitchell, Angela M.; Hirsch, Matthew L.; Li, Chengwen
2014-01-01
Tripartite motif proteins are important viral restriction factors and affect processes ranging from uncoating to transcription to immune signaling. Specifically, the promyelocytic leukemia protein (TRIM19; also called PML) is a viral restriction factor inhibiting processes from uncoating to transcription to cell survival. Here we investigated PML's effect on adeno-associated virus (AAV), a parvovirus used for gene delivery. Although dependovirus (AAV) and autonomous parvovirus (minute virus of mice) replication centers can colocalize with PML, PML's functional effect on parvoviruses is unknown. Using PML knockout mice, we determined that PML knockout enhances recombinant AAV2 (rAAV2) transduction at a range of vector doses in both male and female mice. In fact, male and female PML knockout mice exhibited up to 56-fold and 28-fold increases in transduction, respectively. PML inhibited several rAAV serotypes, suggesting a conserved mechanism, and organ specificity correlated with PML expression. Mechanistically, PML inhibited rAAV second-strand DNA synthesis, precluding inhibition of self-complementary rAAV, and did not affect the prior steps in transduction. Furthermore, we confirmed the effect of human PML on rAAV transduction through small interfering RNA (siRNA)-mediated knockdown in HuH7 cells and determined that the highest level of inhibition was due to effects of PML isoform II (PMLII). Overexpression of PMLII resulted in inhibition of second-strand synthesis, vector production, and genome replication. Moreover, wild-type AAV2 production and infectivity were also inhibited by PMLII, demonstrating a PML interaction with wild-type AAV. These data have important implications for AAV-mediated gene therapy. Additionally, PMLII inhibition of AAV second-strand synthesis and replication, which are processes necessary for all parvoviruses, suggests implications for replication of other parvoviruses. PMID:24198403
Promyelocytic leukemia protein is a cell-intrinsic factor inhibiting parvovirus DNA replication.
Mitchell, Angela M; Hirsch, Matthew L; Li, Chengwen; Samulski, R Jude
2014-01-01
Tripartite motif proteins are important viral restriction factors and affect processes ranging from uncoating to transcription to immune signaling. Specifically, the promyelocytic leukemia protein (TRIM19; also called PML) is a viral restriction factor inhibiting processes from uncoating to transcription to cell survival. Here we investigated PML's effect on adeno-associated virus (AAV), a parvovirus used for gene delivery. Although dependovirus (AAV) and autonomous parvovirus (minute virus of mice) replication centers can colocalize with PML, PML's functional effect on parvoviruses is unknown. Using PML knockout mice, we determined that PML knockout enhances recombinant AAV2 (rAAV2) transduction at a range of vector doses in both male and female mice. In fact, male and female PML knockout mice exhibited up to 56-fold and 28-fold increases in transduction, respectively. PML inhibited several rAAV serotypes, suggesting a conserved mechanism, and organ specificity correlated with PML expression. Mechanistically, PML inhibited rAAV second-strand DNA synthesis, precluding inhibition of self-complementary rAAV, and did not affect the prior steps in transduction. Furthermore, we confirmed the effect of human PML on rAAV transduction through small interfering RNA (siRNA)-mediated knockdown in HuH7 cells and determined that the highest level of inhibition was due to effects of PML isoform II (PMLII). Overexpression of PMLII resulted in inhibition of second-strand synthesis, vector production, and genome replication. Moreover, wild-type AAV2 production and infectivity were also inhibited by PMLII, demonstrating a PML interaction with wild-type AAV. These data have important implications for AAV-mediated gene therapy. Additionally, PMLII inhibition of AAV second-strand synthesis and replication, which are processes necessary for all parvoviruses, suggests implications for replication of other parvoviruses.
What is measured by hyper-Rayleigh scattering from a liquid?
NASA Astrophysics Data System (ADS)
Rodriquez, Micheal B.; Shelton, David P.
2018-04-01
Polarization and angle dependence of hyper-Rayleigh scattering (HRS) measured for liquid acetonitrile and dimethyl sulfoxide (DMSO) is analyzed in terms of contributions from randomly oriented molecules and additional contributions produced during intermolecular collisions and induced by the electric field of dissolved ions. All three contributions show the effect of long-range correlation, and the correlation functions are determined using the HRS observations combined with the results of molecular dynamics simulations. HRS from acetonitrile is polarized transverse to the scattering vector. This is due to long-range molecular orientation correlation produced by the dipole-dipole interaction, and correlation at distances r > 100 nm must be included to account for the HRS observations. Analysis of the HRS measurements for acetonitrile determines the length scale a = 0.185 nm for the long-range longitudinal and transverse orientation correlation functions BL=-2 BT=a3/r3. Transverse polarized collision-induced HRS is also observed for acetonitrile, indicating long-range correlation of intermolecular modes. Strong longitudinal HRS is induced by the radial electric field of dissolved ions in acetonitrile. For DMSO, the angle between the molecular dipole and the vector part of the first hyperpolarizability tensor is about 100°. As a result, HRS from the randomly oriented molecules in DMSO is nearly unaffected by dipole correlation, and ion-induced HRS is weak. The strong longitudinal polarized HRS observed for DMSO is due to the collision-induced contribution, indicating long-range correlation of intermolecular modes. The HRS observations require correlation that has r-3 long-range asymptotic form, for molecular orientation and for intermolecular vibration and libration, for both acetonitrile and DMSO.
Yang, De-Bin; Tong, Yan; Ma, Zhen-Shan; Wang, Lin; Dong, Mei-Hong; Li, Yan-Ling; Wang, Jin-Yu
2013-03-01
To establish an HPLC method for the determination of ephedrine hydrochloride, D-pseudo-ephedrine and amygdalin in Xiao'er Pingchuan Qutan granule. Pheny ether chromatographic column (4.6 mm x 250 mm, 5 microm) was adopted, with acetonitrile-0.1% phosphoric acid (containing 0.1% three ethylamine) (3:97) as the mobile phase. The UV detection wavelength was at 210 nm, with the flow rate of 1 mL x min(-1), and column temperature was at 35 degrees C. The linearity of ephedrine hydrochloride, D-pseudo-ephedrine and amygdalin ranged between 0.078 60-3.144 microg (r = 1.000 0), 0.103 4-2.068 microg (r = 0.999 7) and 0.430 5-3.157 microg (r = 0.999 8), respectively. Their average recoveries were 98.46% (RSD 1.1%), 103.0% (RSD 1.5%) and 97.15% (RSD 2.1%), respectively. The method is simple, stable and reliable that it can be used to determine the content of ephedrine hydrochloride, D-pseudo-ephedrine and amygdalin in Xiao'er Pingchuan Qutan granule.
LeBouf, Ryan F; Miller, Arthur L; Stipe, Christopher; Brown, Jonathan; Murphy, Nate; Stefaniak, Aleksandr B
2013-06-01
Laboratory measurements of ultrafine titanium dioxide (TiO2) particulate matter loaded on filters were made using three field portable methods (X-ray fluorescence (XRF), laser-induced breakdown spectroscopy (LIBS), and Fourier-transform infrared (FTIR) spectroscopy) to assess their potential for determining end-of-shift exposure. Ultrafine TiO2 particles were aerosolized and collected onto 37 mm polycarbonate track-etched (PCTE) filters in the range of 3 to 578 μg titanium (Ti). Limit of detection (LOD), limit of quantification (LOQ), and calibration fit were determined for each measurement method. The LOD's were 11.8, 0.032, and 108 μg Ti per filter, for XRF, LIBS, and FTIR, respectively and the LOQ's were 39.2, 0.11, and 361 μg Ti per filter, respectively. The XRF calibration curve was linear over the widest dynamic range, up to the maximum loading tested (578 μg Ti per filter). LIBS was more sensitive but, due to the sample preparation method, the highest loaded filter measurable was 252 μg Ti per filter. XRF and LIBS had good predictability measured by regressing the predicted mass to the gravimetric mass on the filter. XRF and LIBS produced overestimations of 4% and 2%, respectively, with coefficients of determination (R(2)) of 0.995 and 0.998. FTIR measurements were less dependable due to interference from the PCTE filter media and overestimated mass by 2% with an R(2) of 0.831.
Malkin, B Z; Lummen, T T A; van Loosdrecht, P H M; Dhalenne, G; Zakirov, A R
2010-07-14
The experimental temperature dependence (T = 2-300 K) of single crystal bulk and site susceptibilities of rare earth titanate pyrochlores R(2)Ti(2)O(7) (R = Sm, Eu, Gd, Tb, Dy, Ho, Er, Yb) is analyzed in the framework of crystal field theory and a mean field approximation. Analytical expressions for the site and bulk susceptibilities of the pyrochlore lattice are derived taking into account long range dipole-dipole interactions and anisotropic exchange interactions between the nearest neighbor rare earth ions. The sets of crystal field parameters and anisotropic exchange coupling constants have been determined and their variations along the lanthanide series are discussed.
Lipid-Lowering Pharmaceutical Clofibrate Inhibits Human Sweet Taste
Kochem, Matthew
2017-01-01
T1R2-T1R3 is a heteromeric receptor that binds sugars, high potency sweeteners, and sweet taste blockers. In rodents, T1R2-T1R3 is largely responsible for transducing sweet taste perception. T1R2-T1R3 is also expressed in non-taste tissues, and a growing body of evidence suggests that it helps regulate glucose and lipid metabolism. It was previously shown that clofibric acid, a blood lipid-lowering drug, binds T1R2-T1R3 and inhibits its activity in vitro. The purpose of this study was to determine whether clofibric acid inhibits sweetness perception in humans and is, therefore, a T1R2-T1R3 antagonist in vivo. Fourteen participants rated the sweetness intensity of 4 sweeteners (sucrose, sucralose, Na cyclamate, acesulfame K) across a broad range of concentrations. Each sweetener was prepared in solution neat and in mixture with either clofibric acid or lactisole. Clofibric acid inhibited sweetness of every sweetener. Consistent with competitive binding, inhibition by clofibric acid was diminished with increasing sweetener concentration. This study provides in vivo evidence that the lipid-lowering drug clofibric acid inhibits sweetness perception and is, therefore, a T1R carbohydrate receptor inhibitor. Our results are consistent with previous in vitro findings. Given that T1R2-T1R3 may in part regulate glucose and lipid metabolism, future studies should investigate the metabolic effects of T1R inhibition. PMID:27742692
DOE Office of Scientific and Technical Information (OSTI.GOV)
Varank, Gamze, E-mail: gvarank@yildiz.edu.tr; Demir, Ahmet, E-mail: ahmetd@yildiz.edu.tr; Yetilmezsoy, Kaan, E-mail: yetilmez@yildiz.edu.tr
2011-11-15
Highlights: > We conduct 1D advection-dispersion modeling to estimate transport parameters. > We examine fourteen phenolic compounds and three inorganic contaminants. > 2-MP, 2,4-DCP, 2,6-DCP, 2,4,5-TCP, 2,3,4,6-TeCP have the highest coefficients. > Dispersion coefficients of Cu are determined to be higher than Zn and Fe. > Transport of phenolics can be prevented by zeolite and bentonite in landfill liners. - Abstract: One-dimensional (1D) advection-dispersion transport modeling was conducted as a conceptual approach for the estimation of the transport parameters of fourteen different phenolic compounds (phenol, 2-CP, 2-MP, 3-MP, 4-MP, 2-NP, 4-NP, 2,4-DNP, 2,4-DCP, 2,6-DCP, 2,4,5-TCP, 2,4,6-TCP, 2,3,4,6-TeCP, PCP) and threemore » different inorganic contaminants (Cu, Zn, Fe) migrating downward through the several liner systems. Four identical pilot-scale landfill reactors (0.25 m{sup 3}) with different composite liners (R1: 0.10 + 0.10 m of compacted clay liner (CCL), L{sub e} = 0.20 m, k{sub e} = 1 x 10{sup -8} m/s, R2: 0.002-m-thick damaged high-density polyethylene (HDPE) geomembrane overlying 0.10 + 0.10 m of CCL, L{sub e} = 0.20 m, k{sub e} = 1 x 10{sup -8} m/s, R3: 0.002-m-thick damaged HDPE geomembrane overlying a 0.02-m-thick bentonite layer encapsulated between 0.10 + 0.10 m CCL, L{sub e} = 0.22 m, k{sub e} = 1 x 10{sup -8} m/s, R4: 0.002-m-thick damaged HDPE geomembrane overlying a 0.02-m-thick zeolite layer encapsulated between 0.10 + 0.10 m CCL, L{sub e} = 0.22 m, k{sub e} = 4.24 x 10{sup -7} m/s) were simultaneously run for a period of about 540 days to investigate the nature of diffusive and advective transport of the selected organic and inorganic contaminants. The results of 1D transport model showed that the highest molecular diffusion coefficients, ranging from 4.77 x 10{sup -10} to 10.67 x 10{sup -10} m{sup 2}/s, were estimated for phenol (R4), 2-MP (R1), 2,4-DNP (R2), 2,4-DCP (R1), 2,6-DCP (R2), 2,4,5-TCP (R2) and 2,3,4,6-TeCP (R1). For all reactors, dispersion coefficients of Cu, ranging from 3.47 x 10{sup -6} m{sup 2}/s to 5.37 x 10{sup -2} m{sup 2}/s, was determined to be higher than others obtained for Zn and Fe. Average molecular diffusion coefficients of phenolic compounds were estimated to be about 5.64 x 10{sup -10} m{sup 2}/s, 5.37 x 10{sup -10} m{sup 2}/s, 2.69 x 10{sup -10} m{sup 2}/s and 3.29 x 10{sup -10} m{sup 2}/s for R1, R2, R3 and R4 systems, respectively. The findings of this study clearly indicated that about 35-50% of transport of phenolic compounds to the groundwater is believed to be prevented with the use of zeolite and bentonite materials in landfill liner systems.« less
Screnci, D; McKeage, M J; Galettis, P; Hambley, T W; Palmer, B D; Baguley, B C
2000-01-01
Previous work has shown platinum drugs to differ in their effects on the peripheral nervous system. To test whether their differential toxicity was due to differences in their partitioning into the peripheral nervous system, we correlated the hydrophobicity, reactivity, tissue accumulation and neurotoxicity of a series of eight platinum analogues. Neurotoxicity was detected by measuring sensory nerve conduction velocity (SNCV) in Wistar rats treated twice per week at the maximum tolerated dose. Tissue platinum concentrations were measured by inductively coupled plasma mass spectrometry. Hydrophobicity (log P) was measured using an octanol-aqueous shake-flask method. The half-life of platinum drug binding to plasma proteins in vitro was determined. The cumulative dose causing altered SNCV ranged from 15 to > 2050 μmol kg−1. Ranking of the compounds by their neurotoxic potency in rats (oxaliplatin >R,R -(DACH)PtC4> ormaplatin >S,S -(DACH)PtCl4>S,S -(DACH)Pt oxalato > cisplatin > carboplatin > JM216) correlated with the frequency of neurotoxicity in patients (r> 0.99;P< 0.05). Ranking the compounds by their peripheral nerve accumulation was cisplatin > carboplatin > oxaliplatin >R,R -(DACH)PtCl4≈S,S -(DACH)PtCl4and did not correlate with neurotoxicity. Log P ranged from – 2.53 to –0.16 but did not correlate with neurotoxicity. Log P correlated inversely with platinum accumulation in dorsal root ganglia (r2= 0.99;P = 0.04), sural nerve (r2= 0.85;P = 0.025), sciatic nerve (r2= 0.98;P = 0.0012), spinal cord (r2= 0.97, P = 0.018) and brain (r2= 0.98, P = 0.001). Reactivity correlated with neurotoxicity potency in rats (r2= 0.89, P = 0.0005) and with the frequency of neurotoxicity in patients (r2= 0.99, P = 0.0002). The hydrophilicity of platinum drugs correlates with platinum sequestration in the peripheral nervous system but not with neurotoxicity. Differences in the reactivity of platinum complexes accounts for some of the variation in their neurotoxicity. © 2000 Cancer Research Campaign PMID:10732773
Sollmann, Nico; Hauck, Theresa; Tussis, Lorena; Ille, Sebastian; Maurer, Stefanie; Boeckh-Behrens, Tobias; Ringel, Florian; Meyer, Bernhard; Krieg, Sandro M
2016-10-24
The spatial resolution of repetitive navigated transcranial magnetic stimulation (rTMS) for language mapping is largely unknown. Thus, to determine a minimum spatial resolution of rTMS for language mapping, we evaluated the mapping sessions derived from 19 healthy volunteers for cortical hotspots of no-response errors. Then, the distances between hotspots (stimulation points with a high error rate) and adjacent mapping points (stimulation points with low error rates) were evaluated. Mean distance values of 13.8 ± 6.4 mm (from hotspots to ventral points, range 0.7-30.7 mm), 10.8 ± 4.8 mm (from hotspots to dorsal points, range 2.0-26.5 mm), 16.6 ± 4.8 mm (from hotspots to apical points, range 0.9-27.5 mm), and 13.8 ± 4.3 mm (from hotspots to caudal points, range 2.0-24.2 mm) were measured. According to the results, the minimum spatial resolution of rTMS should principally allow for the identification of a particular gyrus, and according to the literature, it is in good accordance with the spatial resolution of direct cortical stimulation (DCS). Since measurement was performed between hotspots and adjacent mapping points and not on a finer-grained basis, we only refer to a minimum spatial resolution. Furthermore, refinement of our results within the scope of a prospective study combining rTMS and DCS for resolution measurement during language mapping should be the next step.
Burki, Umar; Straub, Volker
2017-01-01
Determining the concentration of oligonucleotide in biological samples such as tissue lysate and serum is essential for determining the biodistribution and pharmacokinetic profile, respectively. ELISA-based assays have shown far greater sensitivities compared to other methods such as HPLC and LC/MS. Here, we describe a novel ultrasensitive hybridization-based ELISA method for quantitating morpholino oligonucleotides in mouse tissue lysate and serum samples. The assay has a linear detection range of 5-250 pM (R2 > 0.99).
Simonsick, Eleanor M; Fan, Ellen; Fleg, Jerome L
2006-01-01
To determine criterion validity of the 400-m walk component of the Long Distance Corridor Walk (LDCW) and develop equations for estimating peak oxygen consumption (VO2) from 400-m time and factors intrinsic to test performance (e.g., heart rate (HR) and systolic blood pressure (SBP) response) in older adults. Cross-sectional validation study. Gerontology Research Center, National Institute on Aging, Baltimore, Maryland. Healthy volunteers (56 men and 46 women) aged 60 to 91 participating in the Baltimore Longitudinal Study of Aging between August 1999 and July 2000. The LDCW, consisting of a 2-minute walk followed immediately by a 400-m walk "done as quickly as possible" over a 20-m course was administered the day after maximal treadmill testing. HR and SBP were measured before testing and at the end of the 400-m walk. Weight, height, activity level, perceived effort, and stride length were also acquired. Peak VO2 ranged from 12.2 to 31.1 mL oxygen/kg per minute, and 400-m time ranged from 2 minutes 52 seconds to 6 minutes 18 seconds. Correlation between 400-m time and peak VO2 was -0.79. The estimating equation from linear regression included 400-m time (partial coefficient of determination (R2)=0.625), long versus short stride (partial R2=0.090), ending SBP (partial R2=0.019), and a correction factor for fast 400-m time (<240 seconds; partial R2=0.020) and explained 75.5% of the variance in peak VO2 (correlation coefficient=0.87). A 400-m walk performed as part of the LDCW provides a valid estimate of peak VO2 in older adults. Incorporating low-cost, safe assessments of fitness in clinical and research settings can identify early evidence of physical decline and individuals who may benefit from therapeutic interventions.
Yaqoob, Mohammad; Asghar, Mohammad; Nabi, Abdul
2015-11-01
A flow-injection (FI) method is reported for the determination of Mn(II), maneb and mancozeb fungicides based on the catalytic effect of Mn(II) on the oxidation of lucigenin and dissolved oxygen in a basic solution. The Tween-20 surfactant has been reported for first time to enhance lucigenin chemiluminescence (CL) intensity in the presence of Mn(II) (53%) and maneb and mancozeb (89%). The calibration graphs were linear in the concentration range of 0.001-1.5 mg L(-1) (R(2) = 0.9982 (n = 11) with a limit of detection (S/N = 3) of 0.1 µg L(-1) for Mn(II) and 0.01-3.0 mg L(-1) [R(2) = 0.9989 and R(2) = 0.9992 (n = 6)] with a limit of detection (S/N =3) of 1.0 µg L(-1) for maneb and mancozeb respectively. Injection throughputs of 90 and 120 h(-1) for Mn(II) and maneb and mancozeb respectively, and relative standard deviations of 1.0-3.4% were obtained in the concentration range studied. The experimental variables, e.g., reagents concentrations, flow rates, sample volume, and photomultiplier tube voltage, were optimized and potential interferences were investigated. The analysis of Mn(II) in river water reference materials (SLRS-4 and SLRS-5) showed good agreement with the certified values incorporating an on-line 8-hydroxyquinoline chelating column in the manifold for removing interfering metal ions. Recoveries for maneb and mancozeb were in the range of 92 ± 5 to 104 ± 3% and 91 ± 2 to 100 ± 4% (n = 3) respectively. The effect of 30 other pesticides (fungicides, herbicides and insecticides) was also examined in the lucigenin-Tween-20 CL system. Copyright © 2015 John Wiley & Sons, Ltd.
NASA Astrophysics Data System (ADS)
Fedorov, V. A.; Karimov, D. N.; Komar'kova, O. N.; Krivandina, E. A.; Zhmurova, Z. I.; Sobolev, B. P.
2010-01-01
Transmission spectra of two-component crystals of Sr1- x R x F2+ x ( R = Y, La-Lu; 0 ≤ x ≤ 0.5) in the 1-17-μm wavelength range were studied. The spectral characteristics of these crystals and of single-component crystals of MF2 ( M = Ca, Sr, or Ba) and RF3 ( R = La-Nd) were compared. The transmission cutoff of Sr1- x R x F2+ x crystals is shifted to shorter wavelengths with increasing x. The same tendency is observed with the increasing atomic number R of rare-earth elements for two isoconcentration series of Sr1- x R x F2+ x ( x ˜ 0.10 and 0.28). This tendency is pronounced at large x. The transmission cutoff of Sr1- x R x F2+ x crystals can be varied in the range of from 10.7 to 12.2 μm by changing their qualitative ( R) and quantitative ( x) composition. Hence, these crystals can be assigned to multicomponent fluoride optical materials with controlled optical characteristics. The Sr1- x R x F2+ x crystals, where R = Ce-Sm, were shown to be promising materials for the design of selective optical filters in the 2-10-μm spectral range.
Motaharian, Ali; Motaharian, Fatemeh; Abnous, Khalil; Hosseini, Mohammad Reza Milani; Hassanzadeh-Khayyat, Mohammad
2016-09-01
In this research, an electrochemical sensor based on molecularly imprinted polymer (MIP) nanoparticles for selective and sensitive determination of diazinon (DZN) pesticides was developed. The nanoparticles of diazinon imprinted polymer were synthesized by suspension polymerization and then used for modification of carbon paste electrode (CPE) composition in order to prepare the sensor. Cyclic voltammetry (CV) and square wave voltammetry (SWV) methods were applied for electrochemical measurements. The obtained results showed that the carbon paste electrode modified by MIP nanoparticles (nano-MIP-CP) has much higher adsorption ability for diazinon than the CPE based non-imprinted polymer nanoparticles (nano-NIP-CP). Under optimized extraction and analysis conditions, the proposed sensor exhibited excellent sensitivity (95.08 μA L μmol(-1)) for diazinon with two linear ranges of 2.5 × 10(-9) to 1.0 × 10(-7) mol L(-1) (R (2) = 0.9971) and 1.0 × 10(-7) to 2.0 × 10(-6) mol L(-1) (R (2) = 0.9832) and also a detection limit of 7.9 × 10(-10) mol.L(-1). The sensor was successfully applied for determination of diaznon in well water and apple fruit samples with recovery values in the range of 92.53-100.86 %. Graphical abstract Procedure for preparation of electrochemical sensor based on MIP nanoparticles for determination of diazinon.
Lee, Zhongping; Shang, Shaoling; Du, Keping; Liu, Bingyi; Lin, Gong; Wei, Jianwei; Li, Xiaolong
2018-05-01
Inversion of the total absorption (a) and backscattering coefficients of bulk water through a fusion of remote sensing reflectance (R rs ) and Secchi disk depth (Z SD ) is developed. An application of such a system to a synthesized wide-range dataset shows a reduction of ∼3 folds in the uncertainties of inverted a(λ) (in a range of ∼0.01-6.8 m -1 ) from R rs (λ) for the 350-560 nm range. Such a fusion is further proposed to process concurrent active (ocean LiDAR) and passive (ocean-color) measurements, which can lead to nearly "exact" analytical inversion of an R rs spectrum. With such a fusion, it is found that the uncertainty in the inverted total a in the 350-560 nm range could be reduced to ∼2% for the synthesized data, which can thus significantly improve the derivation of a coefficients of other varying components. Although the inclusion of Z SD places an extra constraint in the inversion of R rs , no apparent improvement over the quasi-analytical algorithm (QAA) was found when the fusion of Z SD and R rs was applied to a field dataset, which calls for more accurate determination of the absorption coefficients from water samples.
Ma, Yuhan; Berman, Avery J L; Pike, G Bruce
2016-12-01
To determine the contribution of paramagnetic dissolved oxygen in blood plasma to blood-oxygenation-level-dependent (BOLD) signal changes in hyperoxic calibrated BOLD studies. Bovine blood plasma samples were prepared with partial pressures of oxygen (pO 2 ) ranging from 110 to 600 mmHg. R 1 , R 2 , and R 2 * of the plasma with dissolved oxygen were measured using quantitative MRI sequences at 3 Tesla. Simulations were performed to predict the relative effects of dissolved oxygen and deoxyhemoglobin changes in hyperoxia calibrated BOLD. The relaxivities of dissolved oxygen in plasma were found to be r 1, O2 =1.97 ± 0.09 ×10 -4 s -1 mmHg -1 , r 2, O2 =2.3 ± 0.7 ×10 -4 s -1 mmHg -1 , and r 2, O2 * = 2.3 ± 0.7 ×10 -4 s -1 mmHg -1 . Simulations predict that neither the transverse nor longitudinal relaxation rates of dissolved oxygen contribute significantly to the BOLD signal during hyperoxia. During hyperoxia, the increases in R 2 and R 2 * of blood from dissolved oxygen in plasma are considerably less than the decreases in R 2 and R 2 * from venous deoxyhemoglobin. R 1 effects due to dissolved oxygen are also predicted to be negligible. As a result, dissolved oxygen in arteries should not contribute significantly to the hyperoxic calibrated BOLD signal. Magn Reson Med 76:1905-1911, 2016. © 2015 International Society for Magnetic Resonance in Medicine. © 2015 International Society for Magnetic Resonance in Medicine.
Glasser, T; Landau, S; Ungar, E D; Perevolotsky, A; Dvash, L; Muklada, H; Kababya, D; Walker, J W
2008-06-01
An ecologically sound approach to the problem of brush encroachment onto Israeli rangeland might be their utilization by goats, but better knowledge of the feeding selectivity and ability of goats to thrive in encroached areas is required to devise viable production systems. Direct observation of bites could provide precise and accurate estimates of diet selection, but construction of a sufficiently large database would require too much time. The present study describes the first attempt to construct fecal near-infrared reflectance spectroscopy (NIRS) calibrations of the botanical and nutritional composition of the diet, and of the total intake of free-ranging goats, based on reference values determined with bite-count procedures. Calibration of fecal NIRS was based on 43 observations encompassing 3 goat breeds and 4 periods (spring, summer, and fall of 2004, and spring of 2005). Each observation comprised 242 min of continuous recording of the species and bite-type category selected by a single animal, on each of 2 consecutive days. The mass and chemical quality of each species and bite-type category-a total of more than 200,000 bites-were determined by using the simulated bite technique. Associated feces were scanned in the 1,100- to 2,500-nm range with a reflectance monochromator. Fecal NIRS calibrations had reasonable precision for dietary percentages of the 3 main botanical components: herbaceous vegetation (as one category; R(2) = 0.85), Phillyrea latifolia (R(2) = 0.89), and tannin-rich Pistacia lentiscus (R(2) = 0.77), with SE of cross-validation (SECV) of 7.8, 6.3, and 5.6% of DM, respectively. The R(2) values for dietary percentages of CP, NDF, IVDMD, and polyethylene glycol-binding tannins were 0.93, 0.88, 0.91, and 0.74, respectively, with SECV values of 0.9, 2.1, 4.3, and 0.9% of DM, respectively. The R(2) values for intakes of herbaceous vegetation, P. latifolia, and P. lentiscus were 0.80, 0.75, and 0.65, with SECV values of 71, 64, and 46 g of DM/d, respectively. The R(2) values for the daily nutrient intakes were below 0.60. Fecal NIRS data can be used to expand the databases of botanical and nutritional dietary composition when observed and resident animals graze simultaneously, but intakes should be calculated from fecal NIRS-predicted dietary DM composition and an independent evaluation of DMI.
Biomechanical factors associated with time to complete a change of direction cutting maneuver.
Marshall, Brendan M; Franklyn-Miller, Andrew D; King, Enda A; Moran, Kieran A; Strike, Siobhán C; Falvey, Éanna C
2014-10-01
Cutting ability is an important aspect of many team sports, however, the biomechanical determinants of cutting performance are not well understood. This study aimed to address this issue by identifying the kinetic and kinematic factors correlated with the time to complete a cutting maneuver. In addition, an analysis of the test-retest reliability of all biomechanical measures was performed. Fifteen (n = 15) elite multidirectional sports players (Gaelic hurling) were recruited, and a 3-dimensional motion capture analysis of a 75° cut was undertaken. The factors associated with cutting time were determined using bivariate Pearson's correlations. Intraclass correlation coefficients (ICCs) were used to examine the test-retest reliability of biomechanical measures. Five biomechanical factors were associated with cutting time (2.28 ± 0.11 seconds): peak ankle power (r = 0.77), peak ankle plantar flexor moment (r = 0.65), range of pelvis lateral tilt (r = -0.54), maximum thorax lateral rotation angle (r = 0.51), and total ground contact time (r = -0.48). Intraclass correlation coefficient scores for these 5 factors, and indeed for the majority of the other biomechanical measures, ranged from good to excellent (ICC >0.60). Explosive force production about the ankle, pelvic control during single-limb support, and torso rotation toward the desired direction of travel were all key factors associated with cutting time. These findings should assist in the development of more effective training programs aimed at improving similar cutting performances. In addition, test-retest reliability scores were generally strong, therefore, motion capture techniques seem well placed to further investigate the determinants of cutting ability.
Kik, Eugenia; Noczyńska, Anna
2010-01-01
Thyroid hormones are crucial for a proper development of the central nervous system (CNS), skeleton and tooth buds. They are important from the early stages of fetal development. The aim of the study was to evaluate the mental development of children with congenital hypothyroidism detected in screening and to determine the effect of TSH, level of thyroid hormones during observation, perinatal factors as well as parental and environmental factors on the children's IQ. 44 children (28 girls and 16 boys) aged 3.5-18 years (mean age 7.3+/- 3.5) were enrolled in the study. The subjects' mental development was analyzed. General intelligence quotient was measured on verbal and non-verbal scale and chosen parameters of mental development were measured. The evaluation of mental development was performed in two age groups: group A - 20 patients in the age range 3.5-5.9 years (mean age 5.3+/-0.8) tested using the Columbus method, and group B - 24 patients in the age range 6-18 years (mean age 10.3+/-2.2) tested on the Wechsler Scale. The intelligence quotient (IQ) in both groups was within the average IQ range on Wechsler scale. Mean IQ values on verbal and non-verbal scale were comparable and within the average IQ range on Wechsler scale. The level of intelligence in group A correlated, on the brink of statistical significance (IS), with the education level of the parents (r=0.32; p=0.0934), while in the group B - IS correlated with birth weight (r=0.62; p=0.00247), it correlated on the brink of statistical significance with the education level of parents (r=0.4; p=0.0532) and mother's age (r=0.41; p=0.0514). The level of intelligence on verbal scale in group B, statistically significant, positively correlated with the body mass at birth (r=0.62; p=0.00147) and negatively with the mean value of TSH in 2-year follow-up period (r=-0.47; p=0.0381). The level of general intelligence and on verbal and non-verbal scale did not correlate with the time of commencement of therapy with LT4, place of residence or TSH value in the screening test. 1. Mental development of the studied children with CH was within normal range. 2. Out of all measured parameters determining mental development, tasks in mathematics, analysis and synthesis, visual concentration and concentration on the hearing level had worst results. 3. The level of TSH in the screening test had no effect on the mental development of children with CH. 4. Out of all environmental factors, parental education influenced the mental development of the studied children.
Erhabor, O; Ejele, O A; Nwauche, C A; Buseri, F I
2005-01-01
Haematologic abnormalities are among the most common manifestations of advanced human immunodeficiency virus (HIV) infection and acquired immunodeficiency syndrome (AIDS). A specific diagnosis of cause, severity and mechanism of cytopenia should be sought because of specific treatments or intervention may be indicated for its correction. This study was to determine some haematological parameters in HIV/AIDS infected Nigerians. One hundred HIV/AIDS infected previously antiretroviral naïve adult Nigerians, aged 18-58 year (males 47 and females 53) consisting of 88 symptomatic and 12 asymptomatic patients recruited into the antiretroviral pilot project in the Haematology department of the University of Port Harcourt Teaching Hospital between June 2002 to July 2003 were studied. Haematological parameters of hemoglobin, white cell count, platelet count, erythrocyte sedimentation rate and differential leucocyte count were determined. Data was analyzed using a multipurpose statistical package version 9 SPSS. The mean haemoglobin was 10.25 +/- 1.97 g/dl (range 6.31-14.2 g/dl), severe anaemia occurred in 80% of subjects while 20% were non-anaemic. Haemoglobin values was found positively correlated to lymphocyte count (r = .319, P = 0.01) and inversely correlated to ESR (r = -.343, P = 0.01) and neutrophil count (r = -.343, P = 0.01). Red cell morphology was variable with majority normochromic and normocytic (64%) and 36% showing hypochromia and anisopoikilocytosis. The mean total WBC count was 4.51 +/- 1.82 x 10(9)/l (range 0.9-8.2 x 10(9)/l). Leucopaenia occurred in 10/100 (10%) of study population. Total white cell count showed a significant inverse correlation to lymphocyte count (r = -.326, P = 0.01). The mean neutrophil count was 2.32 +/- 1.58 x 10(9)/l (range 0.00-5.48). Neutropaenia occurred in 24% of subjects. Neutrophil count showed a significant positive correlation with total white cell count (r = .314, P = 0.01) and a negative correlation with lymphocyte count (r = -.982, P = 0.01). Striking eosinophilia occurred in 3% of subjects. The mean platelet count was 170.07 +/- 49.03 x 10(9)/l (range 72-158 x 268 x 10(9)/l). Thrombocytopaenia occurred in 10/100 (10%) of subjects. The mean erythrocyte sedimentation rate was higher than that in healthy Africans (mean 78.87 +/- 39.33mm fall/hour (range 0.2-158mm fall/hour). Observation from this study will serve as a guide to clinicians caring for HIV patients in taking rational decision on haematological complications of HIV infection. This constitutes further evidence of the need for routine monitoring of some haematological parameters of HIV/AIDS infected Africans and before commencement of highly active antiretroviral therapy to ensure that mortality and morbidity are minimized and quality of life optimized.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nagai, Tsukasa; Japan Society for the Promotion of Science, 1-8 Chiyoda-ku, Tokyo 102-8472; Tamura, Shinji
2010-07-15
Rare-earth ammonium sulfate octahydrates of R{sub 2}(SO{sub 4}){sub 3}.(NH{sub 4}){sub 2}SO{sub 4}.8H{sub 2}O (R=Pr, Nd, Sm, and Eu) were synthesized by a wet process, and the stable temperature region for the anhydrous R{sub 2}(SO{sub 4}){sub 3}.(NH{sub 4}){sub 2}SO{sub 4} form was clarified by thermogravimetry/differential thermal analysis, infrared, Raman, and electrical conductivity measurements. Detailed characterization of these double salts demonstrated that the thermal stability of anhydrous R{sub 2}(SO{sub 4}){sub 3}.(NH{sub 4}){sub 2}SO{sub 4} is different between the Pr, Nd salts and the Sm, Eu salts, and the thermal decomposition behavior of these salts was quite different from the previous reports. -more » Graphical abstract: Stable temperature range of anhydrous rare-earth ammonium sulfate R{sub 2}(SO{sub 4}){sub 3}.(NH{sub 4}){sub 2}SO{sub 4} was clarified by thermogravimetry/differential thermal analysis, infrared, Raman, and electrical conductivity measurements. Since the previous reports were based only on thermal analysis, the present work has more accurately determined the exact thermal stability of rare-earth ammonium sulfate solids.« less
Chen, Zhihong; Luo, Qingqing; Wang, Mingzi; Chen, Bilian
2017-03-01
A rapid, sensitive and validated method for the determination of fusaric acid (FA) in several Fusarium strains and different commercial food and feed products is reported based on ultra-performance liquid chromatography. This method requires only crude sample by a simple extraction with methanol, and requires a very short time of 8 min for completion. Separation of FA was performed at injection volume of 1 μl with a 20:80 (v/v) water/acetonitrile mobile phase containing 0.1 % formic acid at a flow rate of 0.05 ml/min and detected with UV at 220 nm. Nice linearity and good correlation coefficient (R 2 > 0.99) were obtained in the concentration range of 1-200 μg/ml. Validation was demonstrated using blank samples spiked at three different concentrations with standard solution, and the method yielded more than 98.2 % recovery efficiencies and below 2.56 % R.S.D. when applied in the analysis of FA produced by Fusarium verticillioides and a set of transgenic strains of this fungus. Satisfactory recoveries in the range of 79.1-105.8 % and R.S.D lower than 10 % were also obtained for the tested commercial food and feed products. The concentration FA detection in the transgenic strains ranged from 9.65 to 135 μg/kg (0.29-4.05 μg per gram of biomass). However, FA was not detected in most of the commercial products with the exception of niblet, oatmeal, red kidney bean and soybean, for which the concentrations of FA ranged from 2.5 to 18 μg/kg (below the permitted maximum). These results show that the proposed method has a great potential application to analyze FA from different sources rapidly.
SU-E-T-402: Y-90 Microspheres (SIR Spheres) for Treatment of Liver Metastasis : Technique
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nair, M
2014-06-01
Purpose: The purpose of this presentation is to discuss the radiation safety and dosimetric technique used for the therapeutic procedure using Y-90 microspheres through intra -arterial administration on patients with liver metastasis Methods: The radiation dosimetry, technique and safety aspects of 14 patients with primary and metastatic liver cancer, treated with Y-90 microsphere (SIR spheres) are discussed. The liver and tumor volumes were determined using the CT and MR scans . The images were imported into the treatment planning system and the liver and tumor volumes and the volume of the liver affected were outlined and the volume calculation wasmore » performed using the software. The lung shunt fraction (LSF) and tumor to liver uptake ratio (TLR) were determined using the nuclear medicine SPECT imaging with Tc-99m MAA. The absorbed dose to the target volume in liver was calculated using the following equation:Dose ? (Gy) = C x E? x 5.92 x 10-6 (Gy/s) x T(1/2)(days) x 1.44 x 8.64 x 104 (s) The distribution of activity in the tumor bed was confirmed by post Y-90 administration imaging using the Bremsstrahlung peak at 30% window. The patient and the procedure room were surveyed and radiation safety instructions were given to the patient Results: The tumor volume ranged from 77 cc to 700 cc, tumor to liver uptake ranged from 3 to 12. The lung shunt fraction varied from 1.08% to 9.0%. The activity administered ranged from 1.0GBq to 2.5 GBq, . The radiation survey in contact with the patient ranged from 1.8 mR/hr to 2.5 mR/hr and reading at 1 meter was less than 0.2 mR/hr Conclusion: The technique for radiation dosimetry and radiation safety for Y-90 microsphere therapy is established. The post treatment imaging helped to confirm the distribution of Y-90 microspheres inside the tumor bed.« less
Last, Isidore; Jortner, Joshua
2004-08-15
In this paper we present a theoretical and computational study of the energetics and temporal dynamics of Coulomb explosion of molecular clusters of deuterium (D2)n/2 (n = 480 - 7.6 x 10(4), cluster radius R0 = 13.1 - 70 A) in ultraintense laser fields (laser peak intensity I = 10(15) - 10(20)W cm(-2)). The energetics of Coulomb explosion was inferred from the dependence of the maximal energy EM and the average energy Eav of the product D+ ions on the laser intensity, the laser pulse shape, the cluster radius, and the laser frequency. Electron dynamics of outer cluster ionization and nuclear dynamics of Coulomb explosion were investigated by molecular dynamics simulations. Several distinct laser pulse shape envelopes, involving a rectangular field, a Gaussian field, and a truncated Gaussian field, were employed to determine the validity range of the cluster vertical ionization (CVI) approximation. The CVI predicts that Eav, EM proportional to R0(2) and that the energy distribution is P(E) proportional to E1/2. For a rectangular laser pulse the CVI conditions are satisfied when complete outer ionization is obtained, with the outer ionization time toi being shorter than both the pulse width and the cluster radius doubling time tau2. By increasing toi, due to the increase of R0 or the decrease of I, we have shown that the deviation of Eav from the corresponding CVI value (Eav(CVI)) is (Eav(CVI) - Eav)/Eav(CVI) approximately (toi/2.91tau2)2. The Gaussian pulses trigger outer ionization induced by adiabatic following of the laser field and of the cluster size, providing a pseudo-CVI behavior at sufficiently large laser fields. The energetics manifest the existence of a finite range of CVI size dependence, with the validity range for the applicability of the CVI being R0 < or = (R0)I, with (R0)I representing an intensity dependent boundary radius. Relating electron dynamics of outer ionization to nuclear dynamics for Coulomb explosion induced by a Gaussian pulse, the boundary radius (R0)I and the corresponding ion average energy (Eav)I were inferred from simulations and described in terms of an electrostatic model. Two independent estimates of (R0)I, which involve the cluster size where the CVI relation breaks down and the cluster size for the attainment of complete outer ionization, are in good agreement with each other, as well as with the electrostatic model for cluster barrier suppression. The relation (Eav)I proportional to (R0)I(2) provides the validity range of the pseudo-CVI domain for the cluster sizes and laser intensities, where the energetics of D+ ions produced by Coulomb explosion of (D)n clusters is optimized. The currently available experimental data [Madison et al., Phys. Plasmas 11, 1 (2004)] for the energetics of Coulomb explosion of (D)n clusters (Eav = 5 - 7 keV at I = 2 x 10(18) W cm(-2)), together with our simulation data, lead to the estimates of R0 = 51 - 60 A, which exceed the experimental estimate of R0 = 45 A. The predicted anisotropy of the D+ ion energies in the Coulomb explosion at I = 10(18) W cm(-2) is in accord with experiment. We also explored the laser frequency dependence of the energetics of Coulomb explosion in the range nu = 0.1 - 2.1 fs(-1) (lambda = 3000 - 140 nm), which can be rationalized in terms of the electrostatic model. (c) 2004 American Institute of Physics.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dacres, Helen, E-mail: helen.dacres@csiro.au; Michie, Michelle; Wang, Jian
2012-08-31
Highlights: Black-Right-Pointing-Pointer First experimental determination of Foerster distance (R{sub 0}) for enhanced BRET systems. Black-Right-Pointing-Pointer Effect of brighter BRET components RLuc2, RLuc8 and Venus was assessed. Black-Right-Pointing-Pointer Using brighter BRET components substantially increased (25%) R{sub 0} of the BRET{sup 1} system. Black-Right-Pointing-Pointer Using brighter BRET components marginally increased (2-9%) R{sub 0} of the BRET{sup 2} system. Black-Right-Pointing-Pointer Brighter BRET components improve the different weaknesses of BRET{sup 1} and BRET{sup 2} systems. -- Abstract: Bioluminescence resonance energy transfer (BRET) is an important tool for monitoring macromolecular interactions and is useful as a transduction technique for biosensor development. Foerster distance (R{sub 0}),more » the intermolecular separation characterized by 50% of the maximum possible energy transfer, is a critical BRET parameter. R{sub 0} provides a means of linking measured changes in BRET ratio to a physical dimension scale and allows estimation of the range of distances that can be measured by any donor-acceptor pair. The sensitivity of BRET assays has recently been improved by introduction of new BRET components, RLuc2, RLuc8 and Venus with improved quantum yields, stability and brightness. We determined R{sub 0} for BRET{sup 1} systems incorporating novel RLuc variants RLuc2 or RLuc8, in combination with Venus, as 5.68 or 5.55 nm respectively. These values were approximately 25% higher than the R{sub 0} of the original BRET{sup 1} system. R{sub 0} for BRET{sup 2} systems combining green fluorescent proteins (GFP{sup 2}) with RLuc2 or RLuc8 variants was 7.67 or 8.15 nm, i.e. only 2-9% greater than the original BRET{sup 2} system despite being {approx}30-fold brighter.« less
Are EMS call volume predictions based on demand pattern analysis accurate?
Brown, Lawrence H; Lerner, E Brooke; Larmon, Baxter; LeGassick, Todd; Taigman, Michael
2007-01-01
Most EMS systems determine the number of crews they will deploy in their communities and when those crews will be scheduled based on anticipated call volumes. Many systems use historical data to calculate their anticipated call volumes, a method of prediction known as demand pattern analysis. To evaluate the accuracy of call volume predictions calculated using demand pattern analysis. Seven EMS systems provided 73 consecutive weeks of hourly call volume data. The first 20 weeks of data were used to calculate three common demand pattern analysis constructs for call volume prediction: average peak demand (AP), smoothed average peak demand (SAP), and 90th percentile rank (90%R). The 21st week served as a buffer. Actual call volumes in the last 52 weeks were then compared to the predicted call volumes by using descriptive statistics. There were 61,152 hourly observations in the test period. All three constructs accurately predicted peaks and troughs in call volume but not exact call volume. Predictions were accurate (+/-1 call) 13% of the time using AP, 10% using SAP, and 19% using 90%R. Call volumes were overestimated 83% of the time using AP, 86% using SAP, and 74% using 90%R. When call volumes were overestimated, predictions exceeded actual call volume by a median (Interquartile range) of 4 (2-6) calls for AP, 4 (2-6) for SAP, and 3 (2-5) for 90%R. Call volumes were underestimated 4% of time using AP, 4% using SAP, and 7% using 90%R predictions. When call volumes were underestimated, call volumes exceeded predictions by a median (Interquartile range; maximum under estimation) of 1 (1-2; 18) call for AP, 1 (1-2; 18) for SAP, and 2 (1-3; 20) for 90%R. Results did not vary between systems. Generally, demand pattern analysis estimated or overestimated call volume, making it a reasonable predictor for ambulance staffing patterns. However, it did underestimate call volume between 4% and 7% of the time. Communities need to determine if these rates of over-and underestimation are acceptable given their resources and local priorities.
Reduction of aflatoxins by Rhizopus oryzae and Trichoderma reesei.
Hackbart, H C S; Machado, A R; Christ-Ribeiro, A; Prietto, L; Badiale-Furlong, E
2014-08-01
This study evaluated the ability of the microorganisms Rhizopus oryzae (CCT7560) and Trichoderma reesei (QM9414), producers of generally recognized as safe (GRAS) enzymes, to reduce the level of aflatoxins B1, B2, G1, G2, and M1. The variables considered to the screening were the initial number of spores in the inoculum and the culture time. The culture was conducted in contaminated 4 % potato dextrose agar (PDA) medium, and the residual mycotoxins were determined every 24 h by HPLC-FL. The fungus R. oryzae has reduced aflatoxins B1, B2, and G1 in the 96 h and aflatoxins M1 and G2 in the range of 120 h of culture by approximately 100 %. The fungus T. reesei has reduced aflatoxins B1, B2, and M1 in the 96 h and aflatoxin G1 in the range of 120 h of culture by approximately 100 %. The highest reduction occurred in the middle of R. oryzae culture.
Klos, Kajetan; Windolf, Markus; Schwieger, Karsten; Kuhn, Philipp; Hänni, Markus; Gueorguiev, Boyko; Hofmann, Gunther O; Mückley, Thomas
2009-12-01
Bone strength is currently measured with indirect techniques. We investigated the use of an intraoperative mechanical measurement for local bone strength determination and prediction of intramedullary-nail fusion failure. We investigated whether intraoperative local bone strength determination may be useful to the surgeon in predicting intramedullary nail hindfoot fusion performance. In seven human specimens, bone mineral density (BMD) was determined with qCT. A device (DensiProbe) specially devised for nailed tibiotalocalcaneal arthrodesis (TTCA) was inserted at the intended calcaneal screw sites of an intramedullary nail, and the cancellous break-away torque was measured. The constructs were then cyclically loaded to failure in dorsiflexion-plantarfexion. The BMD range was wide (42.8 to 185.9 mg HA/cm(3)). The proximal-screw site peak torque was 0.47 to 1.61 Nm; distal-screw site peak torque was 0.24 to 1.06 Nm. The number of cycles to failure correlated with peak torque both proximally (p = 0.021; r(2) = 0.69) and distally (p = 0.001; r(2) = 0.92). Proximally, peak torque did not correlate with BMD (p = 0.060; r(2) = 0.54); distally, it correlated significantly (p = 0.003; r(2) = 0.86). DensiProbe measurements can be used in the hindfoot to assess bone strength. In this study, specimens that failed early could be identified. However, in clinical practice fusion failure is multifactorial in origin, and failure prediction cannot be based upon peak torque measurements alone. The technique described here may be of use to give an intraoperative decision aid to predict intramedullary nail hindfoot fusion performance.
Hall, Emily A; Docherty, Carrie L
2017-07-01
To determine the concurrent validity of standard clinical outcome measures compared to laboratory outcome measure while performing the weight-bearing lunge test (WBLT). Cross-sectional study. Fifty participants performed the WBLT to determine dorsiflexion ROM using four different measurement techniques: dorsiflexion angle with digital inclinometer at 15cm distal to the tibial tuberosity (°), dorsiflexion angle with inclinometer at tibial tuberosity (°), maximum lunge distance (cm), and dorsiflexion angle using a 2D motion capture system (°). Outcome measures were recorded concurrently during each trial. To establish concurrent validity, Pearson product-moment correlation coefficients (r) were conducted, comparing each dependent variable to the 2D motion capture analysis (identified as the reference standard). A higher correlation indicates strong concurrent validity. There was a high correlation between each measurement technique and the reference standard. Specifically the correlation between the inclinometer placement at 15cm below the tibial tuberosity (44.9°±5.5°) and the motion capture angle (27.0°±6.0°) was r=0.76 (p=0.001), between the inclinometer placement at the tibial tuberosity angle (39.0°±4.6°) and the motion capture angle was r=0.71 (p=0.001), and between the distance from the wall clinical measure (10.3±3.0cm) to the motion capture angle was r=0.74 (p=0.001). This study determined that the clinical measures used during the WBLT have a high correlation with the reference standard for assessing dorsiflexion range of motion. Therefore, obtaining maximum lunge distance and inclinometer angles are both valid assessments during the weight-bearing lunge test. Copyright © 2016 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.
Exposure to trinitrotoluene and health effects among workers in an artillery and ammunition plant.
Kongtip, Pornpimol; Preklang, Smart; Yoosook, Witaya; Chantanakul, Suttinun
2012-06-01
To determine urinary trinitrotoluene (TNT), 2-amino-4, 6-dinitrotoluene (2ADNT) and 4-amino-2, 6-dinitrotoluene (4ADNT) and health effects upon workers in an ammunition plant. The urine samples from forty munition workers and forty office workers were monitored for TNT and its metabolites by gas chromatography-mass spectrometry. The workers were interviewed with a questionnaire. The median levels of TNT and its metabolites were 112.84 and ranged from non-detectable (ND) to 1,833.81 mg/L. Median levels for 2ADNT were 11.66, ranging from ND to 360.89 mg/L. Median levels for 4ADNT were 19.95 and ranged from ND to 314.28 mg/L. There were significant correlations between TNT and 2ADNT in urine (r = 0. 700, p-value < 0.001), as well as for TNT and 4ADNT (r = 0.783, p-value < 0.001). Exposed workers reported eye, nose and throat irritations, weakness and headaches with considerably higher frequency than non-exposed workers. TNT levels in urine were strongly associated with 4ADNT and 2ADNT levels. Workers exposed to TNT complained of nose, throat and eye irritation, along with overall weakness and headaches.
Apostolidou, Ioanna; Morrissette, Greg; Sarwar, Muhammad F; Konia, Mojca R; Kshettry, Vibhu R; Wahr, Joyce A; Lobbestael, Aaron A; Nussmeier, Nancy A
2012-12-01
This "real-world" study was designed to assess the patterns of regional cerebral oxygen saturation (rSO(2)) change during adult cardiac surgery. A secondary objective was to determine any relation between perioperative rSO(2) (baseline and during surgery) and patient characteristics or intraoperative variables. Prospective, observational, multicenter, nonrandomized clinical study. Cardiac operating rooms at 3 academic medical centers. Ninety consecutive adult patients presenting for cardiac surgery with or without cardiopulmonary bypass. Patients received standard care at each institution plus bilateral forehead recordings of cerebral oxygen saturation with the 7600 Regional Oximeter System (Nonin Medical, Plymouth, MN). The average baseline (before induction) rSO(2) was 63.9 ± 8.8% (range 41%-95%); preoperative hematocrit correlated with baseline rSO(2) (0.48% increase for each 1% increase in hematocrit, p = 0.008). The average nadir (lowest recorded rSO(2) for any given patient) was 54.9 ± 6.6% and was correlated with on-pump surgery, baseline rSO(2), and height. Baseline rSO(2) was found to be an independent predictor of length of stay (hazard ratio 1.044, confidence interval 1.02-1.07, for each percentage of baseline rSO(2)). In cardiac surgical patients, lower baseline rSO(2) value, on-pump surgery, and height were significant predictors of nadir rSO(2), whereas only baseline rSO(2) was a predictor of postoperative length of stay. These findings support previous research on the predictive value of baseline rSO(2) on length of stay and emphasize the need for further research regarding the clinical relevance of baseline rSO(2) and intraoperative changes. Copyright © 2012 Elsevier Inc. All rights reserved.
A new method to estimate average hourly global solar radiation on the horizontal surface
NASA Astrophysics Data System (ADS)
Pandey, Pramod K.; Soupir, Michelle L.
2012-10-01
A new model, Global Solar Radiation on Horizontal Surface (GSRHS), was developed to estimate the average hourly global solar radiation on the horizontal surfaces (Gh). The GSRHS model uses the transmission function (Tf,ij), which was developed to control hourly global solar radiation, for predicting solar radiation. The inputs of the model were: hour of day, day (Julian) of year, optimized parameter values, solar constant (H0), latitude, and longitude of the location of interest. The parameter values used in the model were optimized at a location (Albuquerque, NM), and these values were applied into the model for predicting average hourly global solar radiations at four different locations (Austin, TX; El Paso, TX; Desert Rock, NV; Seattle, WA) of the United States. The model performance was assessed using correlation coefficient (r), Mean Absolute Bias Error (MABE), Root Mean Square Error (RMSE), and coefficient of determinations (R2). The sensitivities of parameter to prediction were estimated. Results show that the model performed very well. The correlation coefficients (r) range from 0.96 to 0.99, while coefficients of determination (R2) range from 0.92 to 0.98. For daily and monthly prediction, error percentages (i.e. MABE and RMSE) were less than 20%. The approach we proposed here can be potentially useful for predicting average hourly global solar radiation on the horizontal surface for different locations, with the use of readily available data (i.e. latitude and longitude of the location) as inputs.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Orsitto, F.; Belforte, M.R.; Borra, M.
1997-01-01
Measurement of plasma radiation (i.e., breusstrahlung) in the infrared (IR) range ({lambda}=933, 978 nm), at six lines of sight from z={minus}20 cm to z=8 cm above the equatorial plane, using the detection system of the Frascati Tokamak Upgrade (FTU) Thomson scattering system (TSS) are reported. The agreement of IR with visible ({lambda}=540 nm) bremsstrahlung intensity {ital S}, [S=photons/(m{sup 2}srnms)] measurements is within 20{percent}{endash}30{percent} and depends upon the absolute calibration of both systems. The intensity is equal S(z)={l_angle}Z{sub eff}Gn{sup 2}/T{sub e}{sup 1/2}{r_angle}, where {l_angle}{center_dot}{r_angle} means average on a line of sight. For determining the Z{sub eff} the Gaunt factor(G) is needed,more » and analysis the Born{endash}Elwert formula is used. The Z{sub eff} spatial profiles (i.e., Z{sub eff}(r)), are determined using the plasma temperature (T{sub e}) and density (n{sub e}) measured by the TSS and the Abel inverted intensity profiles, determined using the plasma radiation S(z) measured from six horizontal chords. Z{sub eff}(r) behavior in a variety of FTU discharges is presented. {copyright} {ital 1997 American Institute of Physics.}« less
Zhang, Susu; He, Ping; Zhang, Guangli; Lei, Wen; He, Huichao
2015-01-01
Graphite nanosheets prepared by thermal expansion and successive sonication were utilized for the construction of a multi-walled carbon nanotubes/graphite nanosheets based amperometric sensing platform to simultaneously determine acetaminophen and dopamine in the presence of ascorbic acid in physiological conditions. The synergistic effect of multi-walled carbon nanotubes and graphite nanosheets catalyzed the electrooxidation of acetaminophen and dopamine, leading to a remarkable potential difference up to 200 mV. The as-prepared modified electrode exhibited linear responses to acetaminophen and dopamine in the concentration ranges of 2.0 × 10(-6) - 2.4 × 10(-4) M (R = 0.999) and 2.0 × 10(-6) - 2.0 × 10(-4) M (R = 0.998), respectively. The detection limits were down to 2.3 × 10(-7) M for acetaminophen and 3.5 × 10(-7) M for dopamine (S/N = 3). Based on the simple preparation and prominent electrochemical properties, the obtained multi-walled carbon nanotubes/graphite nanosheets modified electrode would be a good candidate for the determination of acetaminophen and dopamine without the interference of ascorbic acid.
Dickmann, Robin S.; Strasburg, Gale M.; Romsos, Dale R.; Wilson, Lori A.; Lai, Grace H.; Huang, Hsimin
2016-01-01
Ferric orthophosphate (FePO4) has had limited use as an iron fortificant in ready-to-eat (RTE) cereal because of its variable bioavailability, the mechanism of which is poorly understood. Even though FePO4 has desirable sensory properties as compared to other affordable iron fortificants, few published studies have well-characterized its physicochemical properties. Semi-crystalline materials such as FePO4 have varying degrees of molecular disorder, referred to as amorphous content, which is hypothesized to be an important factor in bioavailability. The objective of this study was to systematically measure the physicochemical factors of particle size, surface area, amorphous content, and solubility underlying the variation in FePO4 bioavailability. Five commercial FePO4 sources and ferrous sulfate were added to individual batches of RTE cereal. The relative bioavailability value (RBV) of each iron source, determined using the AOAC Rat Hemoglobin Repletion Bioassay, ranged from 51% to 99% (p < 0.05), which is higher than typically reported. Solubility in dilute HCl accurately predicted RBV (R2 = 0.93, p = 0.008). Amorphous content measured by Dynamic Vapor Sorption ranged from 1.7% to 23.8% and was a better determinant of solubility (R2 = 0.91; p = 0.0002) than surface area (R2 = 0.83; p = 0.002) and median particle size (R2 = 0.59; p = 0.12). The results indicate that while solubility of FePO4 is highly predictive of RBV, solubility, in turn, is strongly linked to amorphous content and surface area. This information may prove useful for the production of FePO4 with the desired RBV. PMID:26938556
Normal ranges of fetal nasal bone length during the second trimester in an Iranian population.
Rahimi-Sharbaf, Fatemeh; Tahmasebpour, Ahmad-Reza; Pirjani, Reihaneh; Ghaffari, Saeed Reza; Rahimi-Foroushani, Abbas
2011-04-01
To provide a normal reference range for nasal bone length (NBL) during the second trimester of pregnancy in an Iranian population. This cross-sectional study was performed on 3201 fetuses at 15 to 28 weeks of gestational age (GA). Both singleton and twin fetuses were evaluated. The relationship between NBL and GA was determined and percentile values for each gestational week were provided. NBL measurement was obtained in 98% of singleton and 96% of twin fetuses. There was a linear relationship between GA and NBL both in singleton (R(2) = 0.62) and in twin (R(2) = 0.74) fetuses. There was no significant difference between twins regarding NBL (p = 0.18). We have provided the normal reference range for NBL during the second trimester in an Iranian population. NBL in singleton and twin fetuses is similar and there is no significant difference between twins regarding NBL. Copyright © 2011 John Wiley & Sons, Ltd.
Robustness of Tomato Quality Evaluation Using a Portable Vis-SWNIRS for Dry Matter and Colour
Subedi, P. P.; Walsh, K. B.
2017-01-01
The utility of a handheld visible-short wave near infrared spectrophotometer utilising an interactance optical geometry was assessed in context of the noninvasive determination of intact tomato dry matter content, as an index of final ripe soluble solids content, and colouration, as an index of maturation to guide a decision to harvest. Partial least squares regression model robustness was demonstrated through the use of populations of different harvest dates or growing conditions for calibration and prediction. Dry matter predictions of independent populations of fruit achieved R2 ranging from 0.86 to 0.92 and bias from −0.14 to 0.03%. For a CIE a⁎ colour model, prediction R2 ranged from 0.85 to 0.96 and bias from −1.18 to −0.08. Updating the calibration model with new samples to extend range in the attribute of interest and in sample matrix is key to better prediction performance. The handheld spectrometry system is recommended for practical implementation in tomato cultivation. PMID:29333161
Temporal changes of soil respiration under different tree species.
Akburak, Serdar; Makineci, Ender
2013-04-01
Soil respiration rates were measured monthly (from April 2007 to March 2008) under four adjacent coniferous plantation sites [Oriental spruce (Picea orientalis L.), Austrian pine (Pinus nigra Arnold), Turkish fir (Abies bornmulleriana L.), and Scots pine (Pinus sylvestris L.)] and adjacent natural Sessile oak forest (Quercus petraea L.) in Belgrad Forest-Istanbul/Turkey. Also, soil moisture, soil temperature, and fine root biomass were determined to identify the underlying environmental variables among sites which are most likely causing differences in soil respiration. Mean annual soil moisture was determined to be between 6.3 % and 8.1 %, and mean annual temperature ranged from 13.0°C to 14.2°C under all species. Mean annual fine root biomass changed between 368.09 g/m(2) and 883.71 g/m(2) indicating significant differences among species. Except May 2007, monthly soil respiration rates show significantly difference among species. However, focusing on tree species, differences of mean annual respiration rates did not differ significantly. Mean annual soil respiration ranged from 0.56 to 1.09 g C/m(2)/day. The highest rates of soil respiration reached on autumn months and the lowest rates were determined on summer season. Soil temperature, soil moisture, and fine root biomass explain mean annual soil respiration rates at the highest under Austrian pine (R (2) = 0.562) and the lowest (R (2) = 0.223) under Turkish fir.
Chen, Xinhui; Bushman, Lane R; McAllister, Kevin J; Anderson, Peter L; Kiser, Jennifer J
2014-12-01
The purpose of this study was to validate a reversed-phase high-performance liquid chromatographic (HPLC), tandem mass spectrometry (MS/MS) assay for the determination of telaprevir and its R-diastereomer (VRT-127394) in acidified and nonacidified human plasma. The chromatographic baseline separation of telaprevir and telaprevir-R was performed on a Waters XBridge(TM) BEH Shield C18 , 2.1 × 75 mm column with a 2.5 µm particle size, under isocratic conditions consisting of a mobile phase of 50:45:5 water-acetonitrile-isopropanol with 1% ammonia at 0.2 mL/min. This method utilized a stable isotope internal standard with 11 deuterium atoms on the structure of the telaprevir molecule (telaprevir-d11). An internal standard for the telaprevir-R (telaprevir-R-d11) was also prepared by incubating telaprevir-d11 in basic solution, which facilitated isomer inter-conversion. The detection and quantitation of telaprevir, telaprevir-R, telaprevir-IS and telaprevir-R-IS was achieved by positive ion electrospray (ESI+) MS/MS detection. The assay quantifiable limit was 5.0 ng/mL when 0.100 mL of acidified human plasma was extracted. Accuracy and precision were validated over the calibration range of 5.0-5000 ng/mL. It was demonstrated using patient samples that, contrary to previous recommendations, quantitation of telaprevir does not require acidified plasma. Copyright © 2014 John Wiley & Sons, Ltd.
An, Jiwoo; Anderson, Jared L
2018-05-15
A double-confined polymeric ionic liquid (PIL) sorbent coating was fabricated for the determination of nine ultraviolet (UV) filters in sample solutions containing high salt content by direct immersion solid-phase microextraction (DI-SPME) coupled to high-performance liquid chromatography (HPLC). The IL monomer and crosslinker cations and anions, namely, 1-vinyl-3-decylimidazolium styrenesulfonate ([VImC 10 ][SS]) and 1,12-di(3-vinylbenzylimidazolium) dodecane distyrenesulfonate ([(VBIm) 2 C 12 ] 2[SS]), were co-polymerized to create a highly stable sorbent coating which allowed for up to 120 direct-immersion extractions in 25% NaCl (w/v) solution without a decrease in its extraction capability. Extraction and desorption parameters such as desorption solvent, agitation rate, extraction time, desorption solvent volume, and desorption time were evaluated and optimized. The analytical performance of the styrenesulfonate anion-based PIL fiber, PIL fiber containing chloride anions, and a commercially available polydimethylsiloxane/divinylbenzene (PDMS/DVB) fiber were compared. Coefficients of determination (R 2 ) for the styrenesulfonate anion-based PIL fiber ranged from 0.995 to 0.999 and the limits of detection (LODs) varied from 0.1 to 5 µg L -1 . The developed method was successfully applied in real water samples including tap, pool, and lake water, and acceptable relative recovery values were obtained. The lifetime of the PIL fiber containing chloride anions as well as the PDMS/DVB fiber were considerably shorter than the PIL fiber containing the styrenesulfonate anion, with both fibers showing a notable decrease in reproducibility and significant damage to the sorbent coating surface after 40 and 70 extractions, respectively. The R 2 values for the chloride anion containing PIL fiber were at or higher than 0.991 with LODs ranging from 0.5 to 5 µg L -1 . For the PDMS/DVB fiber, R 2 values ranged from 0.992 to 0.999 and LODs were found to be as low as 0.2 µg L -1 and as high as 5 µg L -1 . Copyright © 2018 Elsevier B.V. All rights reserved.
Wang, Guangji; Wang, Qian; Rao, Tai; Shen, Boyu; Kang, Dian; Shao, Yuhao; Xiao, Jingcheng; Chen, Huimin; Liang, Yan
2016-06-15
Pidotimod, (R)-3-[(S)-(5-oxo-2-pyrrolidinyl) carbonyl]-thiazolidine-4-carboxylic acid, was frequently used to treat children with recurrent respiratory infections. Preclinical pharmacokinetics of pidotimod was still rarely reported to date. Herein, a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated to determine pidotimod in rat plasma, tissue homogenate and Caco-2 cells. In this process, phenacetin was chosen as the internal standard due to its similarity in chromatographic and mass spectrographic characteristics with pidotimod. The plasma calibration curves were established within the concentration range of 0.01-10.00μg/mL, and similar linear curves were built using tissue homogenate and Caco-2 cells. The calibration curves for all biological samples showed good linearity (r>0.99) over the concentration ranges tested. The intra- and inter-day precision (RSD, %) values were below 15% and accuracy (RE, %) was ranged from -15% to 15% at all quality control levels. For plasma, tissue homogenate and Caco-2 cells, no obvious matrix effect was found, and the average recoveries were all above 75%. Thus, the method demonstrated excellent accuracy, precision and robustness for high throughput applications, and was then successfully applied to the studies of absorption in rat plasma, distribution in rat tissues and intracellular uptake characteristics in Caco-2 cells for pidotimod. Copyright © 2016 Elsevier B.V. All rights reserved.
Estimation of the center of rotation using wearable magneto-inertial sensors.
Crabolu, M; Pani, D; Raffo, L; Cereatti, A
2016-12-08
Determining the center of rotation (CoR) of joints is fundamental to the field of human movement analysis. CoR can be determined using a magneto-inertial measurement unit (MIMU) using a functional approach requiring a calibration exercise. We systematically investigated the influence of different experimental conditions that can affect precision and accuracy while estimating the CoR, such as (a) angular joint velocity, (b) distance between the MIMU and the CoR, (c) type of the joint motion implemented, (d) amplitude of the angular range of motion, (e) model of the MIMU used for data recording, (f) amplitude of additive noise on inertial signals, and (g) amplitude of the errors in the MIMU orientation. The evaluation process was articulated at three levels: assessment through experiments using a mechanical device, mathematical simulation, and an analytical propagation model of the noise. The results reveal that joint angular velocity significantly impacted CoR identification, and hence, slow joint movement should be avoided. An accurate estimation of the MIMU orientation is also fundamental for accurately subtracting the contribution owing to gravity to obtain the coordinate acceleration. The unit should be preferably attached close to the CoR, but both type and range of motion do not appear to be critical. When the proposed methodology is correctly implemented, error in the CoR estimates is expected to be <3mm (best estimates=2±0.5mm). The findings of the present study foster the need to further investigate this methodology for application in human subjects. Copyright © 2016 Elsevier Ltd. All rights reserved.
Logan, Samuel W; Barnett, Lisa M; Goodway, Jacqueline D; Stodden, David F
2017-04-01
Process-oriented motor competence (MC) assessments evaluate how a movement is performed. Product-oriented assessments evaluate the outcome of a movement. Determining the concurrent validity of process and product assessments is important to address the predictive utility of motor competence for health. The current study aimed to: (1) compare process and product assessments of the standing long jump, hop and throw across age groups and (2) determine the capacity of process assessments to classify levels of MC. Participants included 170 children classified into three age groups: 4-5, 7-8 and 10-11 years old. Participants' skills were examined concurrently using three process assessments ((Test of Gross Motor Development-2nd edition [TGMD-2]), Get Skilled; Get Active, and developmental sequences) and one product measure (throw speed, jump and hop distance). Results indicate moderate to strong correlations between (1) process assessments across skills and age groups (r range = .37-70) and (2) process and product assessments across skills and age groups (r range = .26-.88). In general, sensitivity to detect advanced skill level is lowest for TGMD-2 and highest for developmental sequences for all three skills. The use of process and product assessments is suggested to comprehensively capture levels of MC in human movement.
Wu, Zhanpin; Zhang, Xiao-Jun; Cody, Robert B; Wolfe, Robert R
2004-01-01
The application of time-of-flight mass spectrometry to isotope ratio measurements has been limited by the relatively low dynamic range of the time-to-digital converter detectors available on commercial LC/ToF-MS systems. Here we report the measurement of phenylalanine isotope ratio enrichment by using a new LC/ToF-MS system with wide dynamic range. Underivatized phenylalanine was injected onto a C18 column directly with 0.1% formic acid/acetonitrile as the mobile phase. The optimal instrument parameters for the time-of-flight mass spectrometer were determined by tuning the instrument with a phenylalanine standard. The accuracy of the isotope enrichment measurement was determined by the injection of standard solutions with known isotope ratios ranging from 0.02% to 9.2%. A plot of the results against the theoretical values gave a linear curve with R2 of 0.9999. The coefficient of variation for the isotope ratio measurement was below 2%. The method is simple, rapid, and accurate and presents an attractive alternative to traditional GC/MS applications.
A 14 h-3 Gpc3 study of cosmic homogeneity using BOSS DR12 quasar sample
NASA Astrophysics Data System (ADS)
Laurent, Pierre; Le Goff, Jean-Marc; Burtin, Etienne; Hamilton, Jean-Christophe; Hogg, David W.; Myers, Adam; Ntelis, Pierros; Pâris, Isabelle; Rich, James; Aubourg, Eric; Bautista, Julian; Delubac, Timothée; du Mas des Bourboux, Hélion; Eftekharzadeh, Sarah; Palanque Delabrouille, Nathalie; Petitjean, Patrick; Rossi, Graziano; Schneider, Donald P.; Yeche, Christophe
2016-11-01
The BOSS quasar sample is used to study cosmic homogeneity with a 3D survey in the redshift range 2.2 < z < 2.8. We measure the count-in-sphere, N(< r), i.e. the average number of objects around a given object, and its logarithmic derivative, the fractal correlation dimension, D2(r). For a homogeneous distribution N(< r) propto r3 and D2(r) = 3. Due to the uncertainty on tracer density evolution, 3D surveys can only probe homogeneity up to a redshift dependence, i.e. they probe so-called ``spatial isotropy". Our data demonstrate spatial isotropy of the quasar distribution in the redshift range 2.2 < z < 2.8 in a model-independent way, independent of any FLRW fiducial cosmology, resulting in 3 - langleD2rangle < 1.7 × 10-3 (2 σ) over the range 250 < r < 1200 h-1 Mpc for the quasar distribution. If we assume that quasars do not have a bias much less than unity, this implies spatial isotropy of the matter distribution on large scales. Then, combining with the Copernican principle, we finally get homogeneity of the matter distribution on large scales. Alternatively, using a flat ΛCDM fiducial cosmology with CMB-derived parameters, and measuring the quasar bias relative to this ΛCDM model, our data provide a consistency check of the model, in terms of how homogeneous the Universe is on different scales. D2(r) is found to be compatible with our ΛCDM model on the whole 10 < r < 1200 h-1 Mpc range. For the matter distribution we obtain 3 - langleD2rangle < 5 × 10-5 (2 σ) over the range 250 < r < 1200 h-1 Mpc, consistent with homogeneity on large scales.
Chen, Xiaohong; Li, Xiaoping; Zhao, Yonggang; Pan, Shengdong; Jin, Micong
2015-07-01
A method based on ultrafast liquid chromatography-tandem mass spectrometry (UFLC-MS/MS) has been developed for the simultaneous determination of seven synthetic pigments in cooked meat product. After the cooked meat products were extracted by mixed extraction agent, purified by WAX column, the UFLC separation was performed on a Shim-pack XR-ODS II column (75 mm x 2.0 mm, 2.2 µm) with a linear gradient elution program of acetonitrile and ammonium acetate (AmAc, 5 mmol/L) as the mobile phase. Electrospray ionization was applied and operated in the negative ion mode. The limits of quantitation (LOQs) for the seven synthetic pigments were in the range of 0.7-5.0 µg/kg. The calibration curves showed good linearities for the seven analytes in their detection ranges, and the correlative coefficients (r) were more than 0.999. The recoveries were between 88.2%-106.5% with the RSDs in the range of 1.2%-5.0%. The method is sensitive, reproducible, quick and adapts to the simultaneous determination of the seven synthetic pigments in cooked meat product.
NASA Astrophysics Data System (ADS)
Chandran, B. D. G.; Backer, D. C.
2002-09-01
We study the propagation of radio waves through a medium possessing density fluctuations that are elongated along the ambient magnetic field and described by an anisotropic Goldreich-Sridhar power spectrum. We derive general formulae for the wave phase structure function Dφ, visibility, angular broadening, diffraction pattern length scales, and scintillation timescale for arbitrary distributions of turbulence along the line of sight and specialize these formulae to idealized cases. In general, Dφ~(δr)5/3 when the baseline δr is in the inertial range of the turbulent density spectrum, and Dφ~(δr)2 when δr is in the dissipation range, just as for an isotropic Kolmogorov spectrum of fluctuations. When the density structures that dominate the scattering have an axial ratio R>>1 (typically R~103), the axial ratio of the broadened image of a point source in the standard Markov approximation is at most ~R1/2, and this maximum value is obtained in the unrealistic case that the scattering medium is confined to a thin screen in which the magnetic field has a single direction. If the projection of the magnetic field within the screen onto the plane of the sky rotates through an angle Δψ along the line of sight from one side of the screen to the other, and if R-1/2<<Δψ<<1, then the axial ratio of the resulting broadened image of a point source is 2(8/3)3/5/Δψ~=3.6/Δψ. The error in this formula increases with Δψ but reaches only ~15% when Δψ=π. This indicates that a moderate amount of variation in the direction of the magnetic field along the line of sight dramatically decreases the anisotropy of a broadened image. When R>>1, the observed anisotropy will in general be determined by the degree of variation of the field direction along the sight line and not by the degree of density anisotropy. Although this makes it difficult to determine observationally the degree of anisotropy in interstellar density fluctuations, observed anisotropies in broadened images provide general support for anisotropic models of interstellar turbulence. Regions in which the angle γ between the magnetic field and line of sight is small cause enhanced scattering due to the increased coherence of density structures along the line of sight. In the exceedingly rare and probably unrealized case that scattering is dominated by regions in which γ<~(δr/l)1/3, where l is the outer scale (stirring scale) of the turbulence, Dφ~(δr)4/3 for δr in the inertial range. In a companion paper (Backer & Chandran) we discuss the semiannual modulation in the scintillation time of a nearby pulsar for which the field direction variation along the line of sight is expected to be moderately small.
Frank, Oliver; Kreissl, Johanna Karoline; Daschner, Andreas; Hofmann, Thomas
2014-03-26
A fast and precise proton nuclear magnetic resonance (qHNMR) method for the quantitative determination of low molecular weight target molecules in reference materials and natural isolates has been validated using ERETIC 2 (Electronic REference To access In vivo Concentrations) based on the PULCON (PULse length based CONcentration determination) methodology and compared to the gravimetric results. Using an Avance III NMR spectrometer (400 MHz) equipped with a broad band observe (BBO) probe, the qHNMR method was validated by determining its linearity, range, precision, and accuracy as well as robustness and limit of quantitation. The linearity of the method was assessed by measuring samples of l-tyrosine, caffeine, or benzoic acid in a concentration range between 0.3 and 16.5 mmol/L (r(2) ≥ 0.99), whereas the interday and intraday precisions were found to be ≤2%. The recovery of a range of reference compounds was ≥98.5%, thus demonstrating the qHNMR method as a precise tool for the rapid quantitation (~15 min) of food-related target compounds in reference materials and natural isolates such as nucleotides, polyphenols, or cyclic peptides.
The influence of speaking rate on nasality in the speech of hearing-impaired individuals.
Dwyer, Claire H; Robb, Michael P; O'Beirne, Greg A; Gilbert, Harvey R
2009-10-01
The purpose of this study was to determine whether deliberate increases in speaking rate would serve to decrease the amount of nasality in the speech of severely hearing-impaired individuals. The participants were 11 severely to profoundly hearing-impaired students, ranging in age from 12 to 19 years (M = 16 years). Each participant provided a baseline speech sample (R1) followed by 3 training sessions during which participants were trained to increase their speaking rate. Following the training sessions, a second speech sample was obtained (R2). Acoustic and perceptual analyses of the speech samples obtained at R1 and R2 were undertaken. The acoustic analysis focused on changes in first (F(1)) and second (F(2)) formant frequency and formant bandwidths. The perceptual analysis involved listener ratings of the speech samples (at R1 and R2) for perceived nasality. Findings indicated a significant increase in speaking rate at R2. In addition, significantly narrower F(2) bandwidth and lower perceptual rating scores of nasality were obtained at R2 across all participants, suggesting a decrease in nasality as speaking rate increases. The nasality demonstrated by hearing-impaired individuals is amenable to change when speaking rate is increased. The influences of speaking rate changes on the perception and production of nasality in hearing-impaired individuals are discussed.
Casa, G; Castrillo, A; Galzerano, G; Wehr, R; Merlone, A; Di Serafino, D; Laporta, P; Gianfrani, L
2008-05-23
We report on a new optical implementation of primary gas thermometry based on laser-absorption spectrometry in the near infrared. The method consists in retrieving the Doppler broadening from highly accurate observations of the line shape of the R(12) nu1+2nu2(0)+nu3 transition in CO2 gas at thermodynamic equilibrium. Doppler width measurements as a function of gas temperature, ranging between the triple point of water and the gallium melting point, allowed for a spectroscopic determination of the Boltzmann constant with a relative accuracy of approximately 1.6 x 10(-4).
NASA Astrophysics Data System (ADS)
Amin, Alaa S.; El-Sheikh, Ragaa; Zahran, Faten; Gouda, Ayman Abou El-fetouh
2007-07-01
A simple, accurate and highly sensitive spectrophotometric method is proposed for the rapid determination of pipazethate hydrochloride, dextromethorphan hydrobromide and drotaverine hydrochloride using chromotrope 2B (C2B) and chromotrope 2R (C2R). The method consists of extracting the formed ion-associates into chloroform in the case of pipazethate HCl and dextromethorphan HBr or into methylene chloride in the case of drotaverine HCl. The ion-associates exhibit absorption maxima at 528, 540 and 532 nm with C2B and at 526, 517 and 522 nm with C2R for pipazethate HCl, dextromethorphan HBr and drotaverine HCl, respectively. The calibration curves resulting from the measurements of absorbance-concentration relations (at the optimum reaction conditions) of the extracted ion-pairs are linear over the concentration range 4.36-52.32 μg mL -1 for pipazethate, 3.7-48.15 μg mL -1 for dextromethorphan and 4.34-60.76 μg mL -1 for drotaverine, respectively. The effect of acidity, reagent concentration, time, solvent and stoichiometric ratio of the ion-associates were estimated. The molar absorptivity and Sandell sensitivity of the reaction products were calculated. Statistical treatment of the results reflects that the procedure is precise, accurate and easily applied for the determination of the drugs under investigation in pure form and in their pharmaceutical preparations.
Pistón, Mariela; Dol, Isabel
2006-01-01
A multiparametric flow system based on multicommutation and binary sampling has been designed for the automated determination of sodium, potassium, calcium, and magnesium in large-volume parenteral solutions and hemodialysis concentrated solutions. The goal was to obtain a computer-controlled system capable of determining the four metals without extensive modifications. The system involved the use of five solenoid valves under software control, allowing the establishment of the appropriate flow conditions for each analyte, that is, sample size, dilution, reagent addition, and so forth. Detection was carried out by either flame atomic emission spectrometry (sodium, potassium) or flame atomic absorption spectrometry (calcium, magnesium). The influence of several operating parameters was studied. Validation was carried out by analyzing artificial samples. Figures of merit obtained include linearity, accuracy, precision, and sampling frequency. Linearity was satisfactory: sodium, r 2 >0.999 ( 0.5 – 3.5 g/L), potassium, r 2 >0.996 (50–150 mg/L), calcium, r 2 >0.999 (30–120 mg/L), and magnesium, r 2 >0.999 (20–40 mg/L). Precision ( s r , %, n=5 ) was better than 2.1 %, and accuracy (evaluated through recovery assays) was in the range of 99.8 %– 101.0 % (sodium), 100.8 – 102.5 % (potassium), 97.3 %– 101.3 % (calcium), and 97.1 %– 99.8 % (magnesium). Sampling frequencies ( h −1 ) were 70 (sodium), 75 (potassium), 70 (calcium), and 58 (magnesium). According to the results obtained, the use of an automated multiparametric system based on multicommutation offers several advantages for the quality control of large-volume parenteral solutions and hemodialysis concentrated solutions. PMID:17671619
Huan, Juan; Liu, Qian; Fei, Airong; Qian, Jing; Dong, Xiaoya; Qiu, Baijing; Mao, Hanping; Wang, Kun
2015-11-15
An amplified solid-state electrochemiluminescence (ECL) biosensor for detection of cholesterol in near-infrared (NIR) range was constructed based on CdTe quantum dots (QDs) decorated multiwalled carbon nanotubes@reduced graphene nanoribbons (CdTe-MWCNTs@rGONRs), which were prepared by electrostatic interactions. The CdTe QDs decorated on the MWCNTs@rGONRs resulted in the amplified ECL intensity by ~4.5 fold and decreased onset potential by ~100 mV. By immobilization of the cholesterol oxidase (ChOx) and NIR CdTe-MWCNTs@rGONRs on the electrode surface, a solid-state ECL biosensor for cholesterol detection was constructed. When cholesterol was added to the detection solution, the immobilized ChOx catalyzed the oxidation of cholesterol to generate H2O2, which could be used as the co-reactant in the ECL system of CdTe-MWCNTs@rGONRs. The as-prepared biosensor exhibited good performance for cholesterol detection including good reproducibility, selectivity, and acceptable linear range from 1 μM to 1mM with a relative low detection limit of 0.33 μM (S/N=3). The biosensor was successfully applied to the determination of cholesterol in biological fluid and food sample, which would open a new possibility for development of solid-state ECL biosensors with NIR emitters. Copyright © 2015 Elsevier B.V. All rights reserved.
Physical Quality Indicators and Mechanical Behavior of Agricultural Soils of Argentina.
Imhoff, Silvia; da Silva, Alvaro Pires; Ghiberto, Pablo J; Tormena, Cássio A; Pilatti, Miguel A; Libardi, Paulo L
2016-01-01
Mollisols of Santa Fe have different tilth and load support capacity. Despite the importance of these attributes to achieve a sustainable crop production, few information is available. The objectives of this study are i) to assess soil physical indicators related to plant growth and to soil mechanical behavior; and ii) to establish relationships to estimate the impact of soil loading on the soil quality to plant growth. The study was carried out on Argiudolls and Hapludolls of Santa Fe. Soil samples were collected to determine texture, organic matter content, bulk density, water retention curve, soil resistance to penetration, least limiting water range, critical bulk density for plant growth, compression index, pre-consolidation pressure and soil compressibility. Water retention curve and soil resistance to penetration were linearly and significantly related to clay and organic matter (R2 = 0.91 and R2 = 0.84). The pedotransfer functions of water retention curve and soil resistance to penetration allowed the estimation of the least limiting water range and critical bulk density for plant growth. A significant nonlinear relationship was found between critical bulk density for plant growth and clay content (R2 = 0.98). Compression index was significantly related to bulk density, water content, organic matter and clay plus silt content (R2 = 0.77). Pre-consolidation pressure was significantly related to organic matter, clay and water content (R2 = 0.77). Soil compressibility was significantly related to initial soil bulk density, clay and water content. A nonlinear and significantly pedotransfer function (R2 = 0.88) was developed to predict the maximum acceptable pressure to be applied during tillage operations by introducing critical bulk density for plant growth in the compression model. The developed pedotransfer function provides a useful tool to link the mechanical behavior and tilth of the soils studied.
Physical Quality Indicators and Mechanical Behavior of Agricultural Soils of Argentina
Pires da Silva, Alvaro; Ghiberto, Pablo J.; Tormena, Cássio A.; Pilatti, Miguel A.; Libardi, Paulo L.
2016-01-01
Mollisols of Santa Fe have different tilth and load support capacity. Despite the importance of these attributes to achieve a sustainable crop production, few information is available. The objectives of this study are i) to assess soil physical indicators related to plant growth and to soil mechanical behavior; and ii) to establish relationships to estimate the impact of soil loading on the soil quality to plant growth. The study was carried out on Argiudolls and Hapludolls of Santa Fe. Soil samples were collected to determine texture, organic matter content, bulk density, water retention curve, soil resistance to penetration, least limiting water range, critical bulk density for plant growth, compression index, pre-consolidation pressure and soil compressibility. Water retention curve and soil resistance to penetration were linearly and significantly related to clay and organic matter (R2 = 0.91 and R2 = 0.84). The pedotransfer functions of water retention curve and soil resistance to penetration allowed the estimation of the least limiting water range and critical bulk density for plant growth. A significant nonlinear relationship was found between critical bulk density for plant growth and clay content (R2 = 0.98). Compression index was significantly related to bulk density, water content, organic matter and clay plus silt content (R2 = 0.77). Pre-consolidation pressure was significantly related to organic matter, clay and water content (R2 = 0.77). Soil compressibility was significantly related to initial soil bulk density, clay and water content. A nonlinear and significantly pedotransfer function (R2 = 0.88) was developed to predict the maximum acceptable pressure to be applied during tillage operations by introducing critical bulk density for plant growth in the compression model. The developed pedotransfer function provides a useful tool to link the mechanical behavior and tilth of the soils studied. PMID:27099925
Short, Stephen; Peterkin, Tessa; Guille, Matthew; Patient, Roger; Sharpe, Colin
2015-01-01
Vertebrate NCoR-family co-repressors play central roles in the timing of embryo and stem cell differentiation by repressing the activity of a range of transcription factors. They interact with nuclear receptors using short linear motifs (SLiMs) termed co-repressor for nuclear receptor (CoRNR) boxes. Here, we identify the pathway leading to increasing co-repressor diversity across the deuterostomes. The final complement of CoRNR boxes arose in an ancestral cephalochordate, and was encoded in one large exon; the urochordates and vertebrates then split this region between 10 and 12 exons. In Xenopus, alternative splicing is prevalent in NCoR2, but absent in NCoR1. We show for one NCoR1 exon that alternative splicing can be recovered by a single point mutation, suggesting NCoR1 lost the capacity for alternative splicing. Analyses in Xenopus and zebrafish identify that cellular context, rather than gene sequence, predominantly determines species differences in alternative splicing. We identify a pathway to diversity for the NCoR family beginning with the addition of a SLiM, followed by gene duplication, the generation of alternatively spliced isoforms and their differential deployment. PMID:26289800
Zheng, Karen S; Small, William C; Mittal, Pardeep K; Cai, Qingpo; Kang, Jian; Moreno, Courtney C
2016-01-01
The purpose was to determine the normal distribution of distended colon volumes as a guide for rectal contrast material administration protocols. All computed tomography colonography studies performed at Emory University Hospital, Atlanta, Georgia, between January 2009 and January 2015, were reviewed retrospectively. In total, 85 subjects were included in the analysis (64% [54 of 85] female and 36% [31 of 85] male). Mean patient age was 65 years (range: 42-86y). Distended colon volumes were determined from colon length and transaxial diameter measurements made using a 3-dimensional workstation. Age, sex, race, height, weight, and body mass index were recorded. The normal distributions of distended colon volumes and lengths were determined. Correlations between colonic volume and colonic length, and demographic variables were assessed. Mean colon volume was 2.1L (range: 0.7-4.4L). Nearly, 17% of patients had a distended colonic volume of >3L. Mean colon length was 197cm (range: 118-285cm). A weak negative correlation was found between age and colonic volume (r = -0.221; P = 0.04). A weak positive correlation was found between body mass index and colonic length (r = 0.368; P = 0.007). Otherwise, no significant correlations were found for distended colonic volume or length and demographic variables. In conclusion, an average of approximately 2L of contrast material may be necessary to achieve full colonic opacification. This volume is larger than previously reported volumes (0.8-1.5L) for rectal contrast material administration protocols. Copyright © 2015 Mosby, Inc. All rights reserved.
Weisz, Adrian; Krantz, Zoe B
2014-01-01
Specifications in the US Code of Federal Regulations (CFR) for the colour additives D&C Red No. 27 (R27) and D&C Red No. 28 (R28) limit the levels of the synthetic by-products 2,3,4,5-tetrachloro-6-(3´,5´-dibromo-2´,4´-dihydroxybenzoyl)benzoic acid (SBBA) and "brominated resorcinol" and of the intermediate 3,4,5,6-tetrachlorophthalic acid (TCPA). The present study reports the development and application of a conventional HPLC method for the quantitative determination of these impurities in R27, R28 and their lakes. Because the CFR-listed "brominated resorcinol" refers to a group of synthetic by-products, six variously brominated resorcinols were examined as possible impurities. Due to their rapid decomposition in the presence of the dye, the existence of any brominated resorcinols in R27 and R28 is highly unlikely, and this supposition is supported by the results obtained in this study. SBBA, 2,4,6-tribromoresorcinol (Br3R, the brominated resorcinol most likely to be found as an impurity) and TCPA were quantified by using five-point calibration curves with data points (w/w) that ranged from 0.066% to 0.820% for SBBA, from 0.050% to 0.499% for Br3R, and from 0.061% to 1.410% for TCPA. The HPLC method was applied to the analysis of test portions from batches of R27, R28 and their lakes submitted to the USFDA for certification by domestic and foreign manufacturers.
Liu, Shanshan; Bian, Zhaoyang; Yang, Fei; Li, Zhonghao; Fan, Ziyan; Zhang, Hongfei; Wang, Ying; Zhang, Yange; Tang, Gangling
2015-01-01
A method to determine residues of the three acid herbicides, 2,4,5-trichlorophenoxyacetic acid, 2,4-dichlorophenoxyacetic acid, and 3,6-dichloro-2-methoxybenzoic acid (dicamba), in tobacco using LC/MS/MS is presented. Because these herbicide residues in tobacco might exist in different forms (free acid, salt, and ester), tobacco samples were first pretreated by alkaline hydrolysis and then the pH was adjusted in order to convert the residues completely to their free acid forms. Dichloromethane extraction and dispersive SPE using C18 sorbent were carried out before LC/MS/MS analysis, and quantification was performed using the internal standard method. Linearity was good for all analytes (R(2) ≥ 0.999) in the concentration range of 0.02 to 0.5 mg/kg. LODs were below 0.05 mg/kg. Recoveries ranged from 80.4 to 93.5%, and RSD was below 10%. This simple, efficient, and sensitive method can be applied to the determination of residues of the three acid herbicides in tobacco.
Cremolini, Chiara; Antoniotti, Carlotta; Pietrantonio, Filippo; Berenato, Rosa; Tampellini, Marco; Baratelli, Chiara; Salvatore, Lisa; Marmorino, Federica; Borelli, Beatrice; Nichetti, Federico; Bironzo, Paolo; Sonetto, Cristina; Bartolomeo, Maria Di; Braud, Filippo de; Loupakis, Fotios; Falcone, Alfredo; Di Maio, M
2017-07-01
The purpose of this study was to evaluate progression-free survival (PFS) and objective response rate (ORR) as surrogate endpoints of overall survival (OS) in modern clinical trials investigating the efficacy of targeted agents in the second-line treatment of metastatic colorectal cancer (mCRC). A systematic search of literature pertaining to randomized phase II and III trials evaluating targeted agents as second-line treatments for mCRC was performed. The strength of the correlation between both PFS and ORR and OS was assessed based on the Pearson's correlation coefficient (R) and the coefficient of determination (R 2 ). Twenty trials, including a total of 7,571 patients, met the search criteria. The median duration of post-progression survival (PPS) was 7.6 months. The median differences between experimental and control arms were 0.65 months (range, -2.4 to 3.4) for the median PFS and 0.7 months (range, -5.8 to 3.9) for the median OS. PFS and ORR showed moderate (R=0.734, R 2 =0.539, p < 0.001) and poor correlation (R=0.169, R 2 =0.029, p=0.476) with OS, respectively. No differences between anti-angiogenic agents and other drugs were evident. Targeted agents investigated in the second-line treatment of mCRC provided minimal PFS gains translating into modest OS improvements. Considering both the moderate correlation between PFS and OS and the short duration of PPS, the OS should remain the preferred primary endpoint for randomized clinical trials in the second-line treatment of mCRC.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ye, Fuzhou; Wang, Chao; National Cancer Centre Singapore, 11 Hospital Drive, Singapore 169610
The crystallization of the novel virulence factors SghA and SghR is reported. Two proteins, SghA and SghR, which were recently identified and characterized as novel bacterial virulence factors regulating the infection of plant hosts by Agrobacterium, were cloned, overexpressed and purified with high yield. Both SghA and SghR form dimers in solution. The purified SghA and SghR were crystallized and the crystals diffracted to 1.9 and 2.1 Å resolution, respectively. Data were collected and processed, and the crystallographic parameters were within acceptable ranges. These results will help in the determination of their structures in order to uncover the molecular mechanismmore » of how these two proteins together control the release of plant defence signals against agrobacteria during pathogen–host interaction.« less
Ghugre, Nilesh R.; Wood, John C.
2010-01-01
Iron overload is a serious condition for patients with β-thalassemia, transfusion-dependent sickle cell anemia and inherited disorders of iron metabolism. MRI is becoming increasingly important in non-invasive quantification of tissue iron, overcoming the drawbacks of traditional techniques (liver biopsy). R2*(1/T2*) rises linearly with iron while R2(1/T2) has a curvilinear relationship in human liver. Although recent work has demonstrated clinically-valid estimates of human liver iron, the calibration varies with MRI sequence, field strength, iron chelation therapy and organ imaged, forcing recalibration in patients. To understand and correct these limitations, a thorough understanding of the underlying biophysics is of critical importance. Toward this end, a Monte Carlo based approach, using human liver as a ‘model’ tissue system, was employed to determine the contribution of particle size and distribution on MRI signal relaxation. Relaxivities were determined for hepatic iron concentrations (HIC) ranging from 0.5–40 mg iron/ g dry tissue weight. Model predictions captured the linear and curvilinear relationship of R2* and R2 with HIC respectively and were within in vivo confidence bounds; contact or chemical exchange mechanisms were not necessary. A validated and optimized model will aid understanding and quantification of iron-mediated relaxivity in tissues where biopsy is not feasible (heart, spleen). PMID:21337413
Billard, Hélène; Simon, Laure; Desnots, Emmanuelle; Sochard, Agnès; Boscher, Cécile; Riaublanc, Alain; Alexandre-Gouabau, Marie-Cécile; Boquien, Clair-Yves
2016-08-01
Human milk composition analysis seems essential to adapt human milk fortification for preterm neonates. The Miris human milk analyzer (HMA), based on mid-infrared methodology, is convenient for a unique determination of macronutrients. However, HMA measurements are not totally comparable with reference methods (RMs). The primary aim of this study was to compare HMA results with results from biochemical RMs for a large range of protein, fat, and carbohydrate contents and to establish a calibration adjustment. Human milk was fractionated in protein, fat, and skim milk by covering large ranges of protein (0-3 g/100 mL), fat (0-8 g/100 mL), and carbohydrate (5-8 g/100 mL). For each macronutrient, a calibration curve was plotted by linear regression using measurements obtained using HMA and RMs. For fat, 53 measurements were performed, and the linear regression equation was HMA = 0.79RM + 0.28 (R(2) = 0.92). For true protein (29 measurements), the linear regression equation was HMA = 0.9RM + 0.23 (R(2) = 0.98). For carbohydrate (15 measurements), the linear regression equation was HMA = 0.59RM + 1.86 (R(2) = 0.95). A homogenization step with a disruptor coupled to a sonication step was necessary to obtain better accuracy of the measurements. Good repeatability (coefficient of variation < 7%) and reproducibility (coefficient of variation < 17%) were obtained after calibration adjustment. New calibration curves were developed for the Miris HMA, allowing accurate measurements in large ranges of macronutrient content. This is necessary for reliable use of this device in individualizing nutrition for preterm newborns. © The Author(s) 2015.
Asati, Ankita; Satyanarayana, G N V; Patel, Devendra K
2017-09-01
Two low density organic solvents based liquid-liquid microextraction methods, namely Vortex assisted liquid-liquid microextraction based on solidification of floating organic droplet (VALLME-SFO) and Dispersive liquid-liquid microextraction based on solidification of floating organic droplet(DLLME-SFO) have been compared for the determination of multiclass analytes (pesticides, plasticizers, pharmaceuticals and personal care products) in river water samples by using liquid chromatography tandem mass spectrometry (LC-MS/MS). The effect of various experimental parameters on the efficiency of the two methods and their optimum values were studied with the aid of Central Composite Design (CCD) and Response Surface Methodology(RSM). Under optimal conditions, VALLME-SFO was validated in terms of limit of detection, limit of quantification, dynamic linearity range, determination of coefficient, enrichment factor and extraction recovery for which the respective values were (0.011-0.219ngmL -1 ), (0.035-0.723ngmL -1 ), (0.050-0.500ngmL -1 ), (R 2 =0.992-0.999), (40-56), (80-106%). However, when the DLLME-SFO method was validated under optimal conditions, the range of values of limit of detection, limit of quantification, dynamic linearity range, determination of coefficient, enrichment factor and extraction recovery were (0.025-0.377ngmL -1 ), (0.083-1.256ngmL -1 ), (0.100-1.000ngmL -1 ), (R 2 =0.990-0.999), (35-49), (69-98%) respectively. Interday and intraday precisions were calculated as percent relative standard deviation (%RSD) and the values were ≤15% for VALLME-SFO and DLLME-SFO methods. Both methods were successfully applied for determining multiclass analytes in river water samples. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Salem, A. A.; Barsoum, B. N.; Izake, E. L.
2004-03-01
New spectrophotometric and fluorimetric methods have been developed to determine diazepam, bromazepam and clonazepam (1,4-benzodiazepines) in pure forms, pharmaceutical preparations and biological fluid. The new methods are based on measuring absorption or emission spectra in methanolic potassium hydroxide solution. Fluorimetric methods have proved selective with low detection limits, whereas photometric methods showed relatively high detection limits. Successive applications of developed methods for drugs determination in pharmaceutical preparations and urine samples were performed. Photometric methods gave linear calibration graphs in the ranges of 2.85-28.5, 0.316-3.16, and 0.316-3.16 μg ml -1 with detection limits of 1.27, 0.08 and 0.13 μg ml -1 for diazepam, bromazepam and clonazepam, respectively. Corresponding average errors of 2.60, 5.26 and 3.93 and relative standard deviations (R.S.D.s) of 2.79, 2.12 and 2.83, respectively, were obtained. Fluorimetric methods gave linear calibration graphs in the ranges of 0.03-0.34, 0.03-0.32 and 0.03-0.38 μg ml -1 with detection limits of 7.13, 5.67 and 16.47 ng ml -1 for diazepam, bromazepam and clonazepam, respectively. Corresponding average errors of 0.29, 4.33 and 5.42 and R.S.D.s of 1.27, 1.96 and 1.14 were obtained, respectively. Statistical Students t-test and F-test have been used and satisfactory results were obtained.
NASA Astrophysics Data System (ADS)
Arayne, M. Saeed; Sultana, Najma; Siddiqui, Farhan Ahmed; Mirza, Agha Zeeshan; Zuberi, M. Hashim
2008-11-01
Two simple and sensitive spectrophotometric methods in ultraviolet and visible region are described for the determination of tranexamic acid in pure form and pharmaceutical preparations. The first method is based on the reaction of the drug with ninhydrin at boiling temperature and by measuring the increase in absorbance at 575 nm as a function of time. The initial rate, rate constant and fixed time (120 min) procedures were used for constructing the calibration graphs to determine the concentration of the drug, which showed a linear response over the concentration range 16-37 μg mL -1 with correlation coefficient " r" 0.9997, 0.996, 0.9999, LOQ 6.968, 7.138, 2.462 μgmL -1 and LOD 2.090, 2.141 and 0.739 μgmL -1, respectively. In second method tranexamic acid was reacted with ferric chloride solution, yellowish orange colored chromogen showed λ max at 375 nm showing linearity in the concentration range of 50-800 μg mL -1 with correlation coefficient " r" 0.9997, LOQ 6.227 μgmL -1 and LOD 1.868 μgmL -1. The variables affecting the development of the color were optimized and the developed methods were validated statistically and through recovery studies. These results were also verified by IR and NMR spectroscopy. The proposed methods have been successfully applied to the determination of tranexamic acid in commercial pharmaceutical formulation.
Shellan, Jeffrey B
2004-08-01
The propagation of an optical beam through atmospheric turbulence produces wave-front aberrations that can reduce the power incident on an illuminated target or degrade the image of a distant target. The purpose of the work described here was to determine by computer simulation the statistical properties of the normalized on-axis intensity--defined as (D/r0)2 SR--as a function of D/r0 and the level of adaptive optics (AO) correction, where D is the telescope diameter, r0 is the Fried coherence diameter, and SR is the Strehl ratio. Plots were generated of (D/r0)2 (SR) and sigmaSR/(SR), where (SR) and sigma(SR) are the mean and standard deviation, respectively, of the SR versus D/r0 for a wide range of both modal and zonal AO correction. The level of modal correction was characterized by the number of Zernike radial modes that were corrected. The amount of zonal AO correction was quantified by the number of actuators on the deformable mirror and the resolution of the Hartmann wave-front sensor. These results can be used to determine the optimum telescope diameter, in units of r0, as a function of the AO design. For the zonal AO model, we found that maximum on-axis intensity was achieved when the telescope diameter was sized so that the actuator spacing was equal to approximately 2r0. For modal correction, we found that the optimum value of D/r0 (maximum mean on-axis intensity) was equal to 1.79Nr + 2.86, where Nr is the highest Zernike radial mode corrected.
Song, Yan; Jiang, Kui; Su, Shuai; Wang, Bangmao; Chen, Guangxia
2018-01-01
The current study aimed to summarize the clinical manifestations and identify the epigenetic mechanisms of gastric mucosa associated lymphoid tissue (MALT) lymphoma, as well as evaluate the long-term effects of Helicobacter pylori (H. pylori) eradication. A total of 122 patients with marginal zone B-cell lymphoma of primary gastric MALT lymphoma were enrolled in the present study. The clinical manifestations of gastric MALT lymphoma, including symptoms, H. pylori state and endoscopic type, were summarized. The response to therapy was evaluated in patients that underwent H. pylori eradication. Survival analysis was estimated using the Kaplan-Meier method. The expression of microRNA-383 (miR-383) in tumor tissues and cell lines was determined using reverse transcription quantitative polymerase chain reaction. Furthermore, bioinformatic analyses, luciferase reporter assays. and western blot analysis identified zinc finger E-box binding homeobox 2 (ZEB2) as a direct target gene of miR-383. An MTT assay was used to examine the function of miR-383 and ZEB2 in MALT lymphoma. The clinical symptoms of patients with gastric MALT lymphoma were non-specific and included epigastric pain, abdominal discomfort and bleeding. The majority of endoscopic types were classified as ulcer, erosion and mucosa edema. The H. pylori infection rate was 79.5% (97/122) and a total of 47 patients underwent eradication therapy. Lymphoma remission was achieved in 93.6% (44/47) of patients and complete remission (CR) was achieved in 74.4% (35/47). The median follow-up time was 38 months (range, 10–132 months) and the median time taken to achieve CR was 4 months (range, 3–7 months). The estimated 3-year survival rate was 90.3% and the 5-year survival rate was 76.2%. Therefore, it was determined that patients with stage I or II gastric MALT lymphoma are able to undergo H. pylori eradication as a first-line treatment and that the survival rate of patients undergoing this treatment is high. Furthermore, it was determined that the mechanism by which miR-383 and ZEB2 contribute to MALT lymphoma progression is by the targeting of ZEB2 by miR-383, which inhibits the proliferation of cancer cells. PMID:29387204
NASA Astrophysics Data System (ADS)
Wang, Shu; Jiang, B. W.; Zhao, He; Chen, Xiaodian; de Grijs, Richard
2017-10-01
Understanding the effects of dust extinction is important to properly interpret observations. The optical total-to-selective extinction ratio, {R}V={A}V/E(B-V), is widely used to describe extinction variations in ultraviolet and optical bands. Since the {R}V=3.1 extinction curve adequately represents the average extinction law of diffuse regions in the Milky Way, it is commonly used to correct observational measurements along sightlines toward diffuse regions in the interstellar medium. However, the {R}V value may vary even along different diffuse interstellar medium sightlines. In this paper, we investigate the optical-mid-infrared (mid-IR) extinction law toward a very diffuse region at l=165^\\circ in the Galactic plane, which was selected based on a CO emission map. Adopting red clump stars as extinction tracers, we determine the optical-mid-IR extinction law for our diffuse region in two APASS bands (B,V), three XSTPS-GAC bands (g,r,I), three 2MASS bands (J,H,{K}s), and two WISE bands (W1,W2). Specifically, 18 red clump stars were selected from the APOGEE-RC catalog based on spectroscopic data in order to explore the diversity of the extinction law. We find that the optical extinction curves exhibit appreciable diversity. The corresponding {R}V ranges from 1.7 to 3.8, while the mean {R}V value of 2.8 is consistent with the widely adopted average value of 3.1 for Galactic diffuse clouds. There is no apparent correlation between {R}V value and color excess E(B-V) in the range of interest, from 0.2 to 0.6 mag, or with specific visual extinction per kiloparsec, {A}V/d.
Mixson, T.R.; Campbell, S.R.; Gill, J.S.; Ginsberg, H.S.; Reichard, M.V.; Schultz, T.L.; Dasch, G.A.
2006-01-01
Ambyomma antericanum (L.) (Acari: Ixodidae) is an aggressive tick that feeds on humans during all postembryonic life stages. In many regions of the United States, it is the tick most commonly found attached to humans. Public health interest has grown recently, due to the recognition of new human pathogens transmitted by A. antericanum and the expanding distribution of the tick. A. americanum is a vector of several bacteria pathogenic to humans. Ehrlichia chaffeensis and Ehrlichia ewingii cause moderate-to-severe febrile illness. 'Rickettsia amblyommii,' a member of the spotted fever group Rickettsia, also has recently been implicated as a possible human pathogen based on serologic evidence from persons recovering from illness after a tick bite. We have determined the prevalence of infection of Ehrlichia chaffeensis, E. ewingii, 'Borrelia lonestari,' and R. amblyommii within A. americanum ticks from 29 sites in nine states. Overall infection prevalences were 4.7% for E. chaffeensis (range, 0-27%), 3.5% for E. ewingii (range, 0-18.6%), 2.5% for B. lonestari (range, 0-12.2%), and 41.2% for R. amblyommii (range, 0-84.0%). In addition, 87 ticks (4.3%) were infected with two or more bacteria. This report documents new distribution records for E. ewingii, B. lonestari, and R. amblyommii and underscores the nonhomogeneous distribution of pathogen foci of infection. Additional surveillance throughout the range of A. antericanum is warranted to increase physician and public awareness of the risk of disease to humans from exposure to the agents transmitted by this tick.
A creatinine biosensor based on admittance measurement
NASA Astrophysics Data System (ADS)
Ching, Congo Tak-Shing; Sun, Tai-Ping; Jheng, Deng-Yun; Tsai, Hou-Wei; Shieh, Hsiu-Li
2015-08-01
Regular check of blood creatinine level is very important as it is a measurement of renal function. Therefore, the objective of this study is to develop a simple and reliable creatinine biosensor based on admittance measurement for precise determination of creatinine. The creatinine biosensor was fabricated with creatinine deiminase immobilized on screen-printed carbon electrodes. Admittance measurement at a specific frequency ranges (22.80 - 84.71 Hz) showed that the biosensor has an excellent linear (r2 > 0.95) response range (50 - 250 uM), which covers the normal physiological and pathological ranges of blood creatinine levels. Intraclass correlation coefficient (ICC) showed that the biosensor has excellent reliability and validity (ICC = 0.98). In conclusion, a simple and reliable creatinine biosensor was developed and it is capable of precisely determining blood creatinine levels in both the normal physiological and pathological ranges.
Fracture resistance of a TiB2 particle/SiC matrix composite at elevated temperature
NASA Technical Reports Server (NTRS)
Jenkins, Michael G.; Salem, Jonathan A.; Seshadri, Srinivasa G.
1988-01-01
The fracture resistance of a comercial TiB2 particle/SiC matrix composite was evaluated at temperatures ranging from 20 to 1400 C. A laser interferometric strain gauge (LISG) was used to continuously monitor the crack mouth opening displacement (CMOD) of the chevron-notched and straight-notched, three-point bend specimens used. Crack growth resistance curves (R-curves) were determined from the load versus displacement curves and displacement calibrations. Fracture toughness, work-of-fracture, and R-curve levels were found to decrease with increasing temperature. Microstructure, fracture surface, and oxidation coat were examined to explain the fracture behavior.
Fracture resistance of a TiB2 particle/SiC matrix composite at elevated temperature
NASA Technical Reports Server (NTRS)
Jenkins, Michael G.; Salem, Jonathan A.; Seshadri, Srinivasa G.
1989-01-01
The fracture resistance of a commercial TiB2 particle/SiC matrix composite was evaluated at temperatures ranging from 20 to 1400 C. A laser interferometric strain gauge (LiSG) was used to continuously monitor the crack mouth opening displacement (CMOD) of the chevron-notched and straight-notched, three-point bend specimens used. Crack growth resistance curves (R-curves) were determined from the load versus displacement curves and displacement calibrations. Fracture toughness, work-of-fracture, and R-curve levels were found to decrease with increasing temperature. Microstructure, fracture surface, and oxidation coat were examined to explain the fracture behavior.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang Fan; Medical Physics Graduate Program, Duke University, Durham, North Carolina; Hu Jing
2012-11-01
Purpose: To evaluate the reproducibility of tumor motion probability distribution function (PDF) in stereotactic body radiation therapy (SBRT) of lung cancer using cine megavoltage (MV) images. Methods and Materials: Cine MV images of 20 patients acquired during three-dimensional conformal (6-11 beams) SBRT treatments were retrospectively analyzed to extract tumor motion trajectories. For each patient, tumor motion PDFs were generated per fraction (PDF{sub n}) using three selected 'usable' beams. Patients without at least three usable beams were excluded from the study. Fractional PDF reproducibility (R{sub n}) was calculated as the Dice similarity coefficient between PDF{sub n} to a 'ground-truth' PDF (PDF{submore » g}), which was generated using the selected beams of all fractions. The mean of R{sub n}, labeled as R{sub m}, was calculated for each patient and correlated to the patient's mean tumor motion rang (A{sub m}). Change of R{sub m} during the course of SBRT treatments was also evaluated. Intra- and intersubject coefficient of variation (CV) of R{sub m} and A{sub m} were determined. Results: Thirteen patients had at least three usable beams and were analyzed. The mean of R{sub m} was 0.87 (range, 0.84-0.95). The mean of A{sub m} was 3.18 mm (range, 0.46-7.80 mm). R{sub m} was found to decrease as A{sub m} increases following an equation of R{sub m} = 0.17e{sup -0.9Am} + 0.84. R{sub m} also decreased slightly throughout the course of treatments. Intersubject CV of R{sub m} (0.05) was comparable to intrasubject CV of R{sub m} (range, 0.02-0.09); intersubject CV of A{sub m} (0.73) was significantly greater than intrasubject CV of A{sub m} (range, 0.09-0.24). Conclusions: Tumor motion PDF can be determined using cine MV images acquired during the treatments. The reproducibility of lung tumor motion PDF decreased exponentially as the tumor motion range increased and decreased slightly throughout the course of the treatments.« less
Skerencak-Frech, Andrej; Fröhlich, Daniel R; Rothe, Jörg; Dardenne, Kathy; Panak, Petra J
2014-01-21
The complexation of trivalent actinides (An(III)) with chloride is studied in the temperature range from 25 to 200 °C by spectroscopic methods. Time-resolved laser fluorescence spectroscopy (TRLFS) is applied to determine the thermodynamic data of Cm(III)-Cl(-) complexes, while extended X-ray absorption fine structure spectroscopy (EXAFS) is used to determine the structural data of the respective Am(III) complexes. The experiments are performed in a custom-built high-temperature cell which is modified for the respective spectroscopic technique. The TRLFS results show that at 25 °C the speciation is dominated mainly by the Cm(3+) aquo ion. Only a minor fraction of the CmCl(2+) complex is present in solution. As the temperature increases, the fraction of this species decreases further. Simultaneously, the fraction of the CmCl2(+) complex increases strongly with the temperature. Also, the CmCl3 complex is formed to a minor extent at T > 160 °C. The conditional stability constant log β'2 is determined as a function of the temperature and extrapolated to zero ionic strength with the specific ion interaction theory approach. The log β°2(T) values increase by more than 3 orders of magnitude in the studied temperature range. The temperature dependency of log β°2 is fitted by the extended van't Hoff equation to determine ΔrH°m, ΔrS°m, and ΔrC°p,m. The EXAFS results support these findings. The results confirm the absence of americium(III) chloride complexes at T = 25 and 90 °C ([Am(III)] = 10(-3) m, [Cl(-)] = 3.0 m), and the spectra are described by 9-10 oxygen atoms at a distance of 2.44-2.48 Å. At T = 200 °C two chloride ligands are present in the inner coordination sphere of Am(III) at a distance of 2.78 Å.
Sun, Xiao-gang; Tang, Hong; Dai, Jing-min
2008-12-01
The problem of determining the particle size range in the visible-infrared region was studied using the independent model algorithm in the total scattering technique. By the analysis and comparison of the accuracy of the inversion results for different R-R distributions, the measurement range of particle size was determined. Meanwhile, the corrected extinction coefficient was used instead of the original extinction coefficient, which could determine the measurement range of particle size with higher accuracy. Simulation experiments illustrate that the particle size distribution can be retrieved very well in the range from 0. 05 to 18 microm at relative refractive index m=1.235 in the visible-infrared spectral region, and the measurement range of particle size will vary with the varied wavelength range and relative refractive index. It is feasible to use the constrained least squares inversion method in the independent model to overcome the influence of the measurement error, and the inverse results are all still satisfactory when 1% stochastic noise is added to the value of the light extinction.
Jian, Jin-Ming; Liu, Yan-Yan; Zhang, Ye-Lei; Guo, Xi-Shan; Cai, Qiang
2013-01-01
In this study, reduced graphene oxide (rGO) was electrochemically deposited on the surface of screen-printed carbon electrodes (SPCE) to prepare a disposable sensor for fast detection of Pb2+ in foods. The SEM images showed that the rGO was homogeneously deposited onto the electrode surface with a wrinkled nanostructure, which provided 2D bridges for electron transport and a larger active area for Pb2+ adsorption. Results showed that rGO modification enhanced the activity of the electrode surface, and significantly improved the electrochemical properties of SPCE. The rGO modified SPCE (rGO-SPCE) was applied to detect Pb2+ in standard aqueous solution, showing a sharp stripping peak and a relatively constant peak potential in square wave anodic stripping voltammetry (SWASV). The linear range for Pb2+ detection was 5∼200 ppb (R2 = 0.9923) with a low detection limit of 1 ppb (S/N = 3). The interference of Cd2+ and Cu2+ at low concentrations was effectively avoided. Finally, the rGO-SPCE was used for determination of lead in real tap water, juice, preserved eggs and tea samples. Compared with results from graphite furnace atomic absorption spectroscopy (GFAAS), the results based on rGO-SPCE were both accurate and reliable, suggesting that the disposable sensor has great potential in application for fast, sensitive and low-cost detection of Pb2+ in foods. PMID:24077322
Determination of some phenolic compounds in red wine by RP-HPLC: method development and validation.
Burin, Vívian Maria; Arcari, Stefany Grützmann; Costa, Léa Luzia Freitas; Bordignon-Luiz, Marilde T
2011-09-01
A methodology employing reversed-phase high-performance liquid chromatography (RP-HPLC) was developed and validated for simultaneous determination of five phenolic compounds in red wine. The chromatographic separation was carried out in a C(18) column with water acidify with acetic acid (pH 2.6) (solvent A) and 20% solvent A and 80% acetonitrile (solvent B) as the mobile phase. The validation parameters included: selectivity, linearity, range, limits of detection and quantitation, precision and accuracy, using an internal standard. All calibration curves were linear (R(2) > 0.999) within the range, and good precision (RSD < 2.6%) and recovery (80-120%) was obtained for all compounds. This method was applied to quantify phenolics in red wine samples from Santa Catarina State, Brazil, and good separation peaks for phenolic compounds in these wines were observed.
Bedekar, Nilima; Suryawanshi, Mayuri; Rairikar, Savita; Sancheti, Parag; Shyam, Ashok
2014-01-01
Evaluation of range of motion (ROM) is integral part of assessment of musculoskeletal system. This is required in health fitness and pathological conditions; also it is used as an objective outcome measure. Several methods are described to check spinal flexion range of motion. Different methods for measuring spine ranges have their advantages and disadvantages. Hence, a new device was introduced in this study using the method of dual inclinometer to measure lumbar spine flexion range of motion (ROM). To determine Intra and Inter-rater reliability of mobile device goniometer in measuring lumbar flexion range of motion. iPod mobile device with goniometer software was used. The part being measure i.e the back of the subject was suitably exposed. Subject was standing with feet shoulder width apart. Spinous process of second sacral vertebra S2 and T12 were located, these were used as the reference points and readings were taken. Three readings were taken for each: inter-rater reliability as well as the intra-rater reliability. Sufficient rest was given between each flexion movement. Intra-rater reliability using ICC was r=0.920 and inter-rater r=0.812 at CI 95%. Validity r=0.95. Mobile device goniometer has high intra-rater reliability. The inter-rater reliability was moderate. This device can be used to assess range of motion of spine flexion, representing uni-planar movement.
[Function in patients with chronic fibrocavernous tuberculosis].
Nefedov, V B; Popova, L A; Shergina, E A
2008-01-01
Vital capacity (VC), forced vital capacity (FVC), forced expiratory volume in 1 second (FEV1), FEV1/VC%, PEF, MEF25, MEF50, MEF75, TLC, TGV, residual volume (RV), R(aw), R(in), R(ex), DLCO-SB, DLCO-SS, PaO2, and PaCO2 were determined in 62 patients with chronic fibrocavernous tuberculosis. Lung dysfunctions were detected in 96.8% of the patients. Changes in lung volumes and capacities were found in 90.3%, impaired bronchial patency was in 90.3%, and pulmonary gas exchange dysfunction was in 79.0%. The lung volume and capacity changes appeared as decreased VC and FVC, decreased and increased TLC, TGV, RV; impaired bronchial patency presented as decreased PEF, MEF25, MEF50, MEF75, and FEV1/VC%; and increased R(aw), R(in), R(ex); pulmonary gas exchange dysfunction manifested itself as reduced DLCO-SB, DLCO-SS, PaO2, and decreased and increased PaCO2. The magnitude of the observed functional changes ranges from slight to significant and drastic with a predominance of considerable and drastic changes in lung volumes and capacities and mild impairments of bronchial patency and pulmonary gas exchange function.
Compact stars in the non-minimally coupled electromagnetic fields to gravity
NASA Astrophysics Data System (ADS)
Sert, Özcan
2018-03-01
We investigate the gravitational models with the non-minimal Y(R)F^2 coupled electromagnetic fields to gravity, in order to describe charged compact stars, where Y( R) denotes a function of the Ricci curvature scalar R and F^2 denotes the Maxwell invariant term. We determine two parameter family of exact spherically symmetric static solutions and the corresponding non-minimal model without assuming any relation between energy density of matter and pressure. We give the mass-radius, electric charge-radius ratios and surface gravitational redshift which are obtained by the boundary conditions. We reach a wide range of possibilities for the parameters k and α in these solutions. Lastly we show that the models can describe the compact stars even in the more simple case α =3.
Renormalization group procedure for potential -g/r2
NASA Astrophysics Data System (ADS)
Dawid, S. M.; Gonsior, R.; Kwapisz, J.; Serafin, K.; Tobolski, M.; Głazek, S. D.
2018-02-01
Schrödinger equation with potential - g /r2 exhibits a limit cycle, described in the literature in a broad range of contexts using various regularizations of the singularity at r = 0. Instead, we use the renormalization group transformation based on Gaussian elimination, from the Hamiltonian eigenvalue problem, of high momentum modes above a finite, floating cutoff scale. The procedure identifies a richer structure than the one we found in the literature. Namely, it directly yields an equation that determines the renormalized Hamiltonians as functions of the floating cutoff: solutions to this equation exhibit, in addition to the limit-cycle, also the asymptotic-freedom, triviality, and fixed-point behaviors, the latter in vicinity of infinitely many separate pairs of fixed points in different partial waves for different values of g.
Detection and quantification of reactive oxygen species (ROS) in indoor air.
Montesinos, V Nahuel; Sleiman, Mohamad; Cohn, Sebastian; Litter, Marta I; Destaillats, Hugo
2015-06-01
Reactive oxygen species (ROS), such as free radicals and peroxides, are environmental trace pollutants potentially associated with asthma and airways inflammation. These compounds are often not detected in indoor air due to sampling and analytical limitations. This study developed and validated an experimental method to sample, identify and quantify ROS in indoor air using fluorescent probes. Tests were carried out simultaneously using three different probes: 2',7'-dichlorofluorescin (DCFH) to detect a broad range of ROS, Amplex ultra Red® (AuR) to detect peroxides, and terephthalic acid (TPA) to detect hydroxyl radicals (HO(•)). For each test, air samples were collected using two impingers in series kept in an ice bath, containing each 10 mL of 50 mM phosphate buffer at pH 7.2. In tests with TPA, that probe was also added to the buffer prior to sampling; in the other two tests, probes and additional reactants were added immediately after sampling. The concentration of fluorescent byproducts was determined fluorometrically. Calibration curves were developed by reacting DCFH and AuR with known amounts of H2O2, and using known amounts of 2-hydroxyterephthalic acid (HTPA) for TPA. Low detection limits (9-13 nM) and quantification limits (18-22 nM) were determined for all three probes, which presented a linear response in the range 10-500 nM for AuR and TPA, and 100-2000 nM for DCFH. High collection efficiency (CE) and recovery efficiency (RE) were observed for DCFH (CE=RE=100%) and AuR (CE=100%; RE=73%) by sampling from a laboratory-developed gas phase H2O2 generator. Interference of co-occurring ozone was evaluated and quantified for the three probes by sampling from the outlet of an ozone generator. The method was demonstrated by sampling air emitted by two portable air cleaners: a strong ozone generator (AC1) and a plasma generator (AC2). High ozone levels emitted by AC1 did not allow for simultaneous determination of ROS levels due to high background levels associated with ozone decomposition in the buffer. However, emitted ROS were quantified at the outlet of AC2 using two of the three probes. With AuR, the concentration of peroxides in air emitted by the air cleaner was 300 ppt of H2O2 equivalents. With TPA, the HO(•) concentration was 47 ppt. This method is best suited to quantify ROS in the presence of low ozone levels. Published by Elsevier B.V.
Validity of the Jump-and-Reach Test in Subelite Adolescent Handball Players.
Muehlbauer, Thomas; Pabst, Jan; Granacher, Urs; Büsch, Dirk
2017-05-01
Muehlbauer, T, Pabst, J, Granacher, U, and Büsch, D. Validity of the jump-and-reach test in subelite adolescent handball players. J Strength Cond Res 31(5): 1282-1289, 2017-The primary purpose of this study was to examine concurrent validity of the jump-and-reach (JaR) test using the Vertec system and a criterion device (i.e., Optojump system). In separate subanalyses, we investigated the influence of gym floor condition and athletes' sex on the validity of vertical jump height. Four hundred forty subelite adolescent female (n = 222, mean age: 14 ± 1 year, age range: 13-15 years) and male (n = 218, mean age: 15 ± 1 year, age range: 14-16 years) handball players performed the JaR test in gyms with region or point elastic floors. Maximal vertical jump height was simultaneously assessed using the Vertec and the Optojump systems. In general, significantly higher jump heights were obtained for the Vertec compared with the Optojump system (11.2 cm, Δ31%, Cohen's d = 2.58). The subanalyses revealed significantly larger jump heights for the Vertec compared with the Optojump system irrespective of gym floor condition and players' sex. The association between Optojump- and Vertec-derived vertical jump heights amounted to rP = 0.84, with a coefficient of determination (R) of 0.71. The subanalyses indicated significantly larger correlations in males (rP = 0.75, R = 0.56) than in females (rP = 0.63, R = 0.40). Yet, correlations were not significantly different between region (rP = 0.83, R = 0.69) as opposed to point elastic floor (rP = 0.87, R = 0.76). Our findings indicate that the 2 apparatuses cannot be used interchangeably. Consequently, gym floor and sex-specific regression equations were provided to estimate true (Optojump system) vertical jump height from Vertec-derived data.
Krukowski, Sylwester; Karasiewicz, Mateusz; Kolodziejski, Waclaw
2017-07-01
Herein, we present a convenient method for quantitative spectrophotometric determination of citrate ions in aqueous solutions in the middle-UV range. It involves measuring the absorbance of citric acid at 209 nm under suppressed dissociation at pH < 1.0 in the presence of hydrochloric acid. Validation of the method was performed according to the guidelines of the International Conference on Harmonization. A very good linear dependence of the absorbance on concentration (r 2 = 0.9999) was obtained in a citrate concentration range of 0.5-5.0 mmol/L. This method is characterized by excellent precision and accuracy; the coefficient of variation in each case is below the maximal permissible value (%RSD < 2). The proposed analytical procedure has been successfully applied to the determination of citrates in oral electrolyte formulations. Copyright © 2017. Published by Elsevier B.V.
Trzcinski, M Kurtis; Walde, Sandra J; Taylor, Philip D
2008-11-01
1. Theory predicting that populations with high maximum rates of increase (r(max)) will be less stable, and that metapopulations with high average r(max) will be less synchronous, was tested using a small protist, Bodo, that inhabits pitcher plant leaves (Sarracenia purpurea L.). The effects of predators and resources on these relationships were also determined. 2. Abundance data collected for a total of 60 populations of Bodo, over a period of 3 months, at six sites in three bogs in eastern Canada, were used to test these predictions. Mosquitoes were manipulated in half the leaves partway through the season to increase the range of predation rates. 3. Dynamics differed greatly among leaves and sites, but most populations exhibited one or more episodes of rapid increase followed by a population crash. Estimates of r(max) obtained using a linear mixed-effects model, ranged from 1 x 5 to 2 x 7 per day. Resource levels (captured insect) and midge abundances affected r(max). 4. Higher r(max) was associated with greater temporal variability and lower synchrony as predicted. However, in contrast to expectations, populations with higher r(max) also had lower mean abundance and were more suppressed by predators. 5. This study demonstrates that the link between r(max) and temporal variability is key to understanding the dynamics of populations that spend little time near equilibrium, and to predicting and interpreting the effects of community structure on the dynamics of such populations.
Quantification of left ventricular myocardial mass in humans by nuclear magnetic resonance imaging.
Ostrzega, E; Maddahi, J; Honma, H; Crues, J V; Resser, K J; Charuzi, Y; Berman, D S
1989-02-01
The ability of NMRI to assess LV mass was studied in 20 normal males. By means of a 1.5 Tesla GE superconducting magnet and a standard spin-echo pulse sequence, multiple gated short-axis and axial slices of the entire left ventricle were obtained. LV mass was determined by Simpson's rule with the use of a previous experimentally validated method. The weight of the LV apex (subject to partial volume effect in the short-axis images) was derived from axial slices and that of the remaining left ventricle from short-axis slices. The weight of each slice was calculated by multiplying the planimetered surface area of the LV myocardium by slice thickness and by myocardial specific gravity (1.05). Mean +/- standard deviation of LV mass and LV mass index were 146 +/- 23.1 gm (range 92.3 to 190.4 gm) and 78.4 +/- 7.8 gm/m2 (range 57.7 to 89.4 gm/m2), respectively. Interobserver agreement as assessed by ICC was high for determining 161 individual slice masses (ICC = 0.99) and for total LV mass (ICC = 0.97). Intraobserver agreement for total LV mass was also high (ICC = 0.96). NMRI-determined LV mass correlated with body surface area: LV mass = 55 + 108 body surface area, r = 0.83; with body weight: LV mass = 26 + 0.77 body weight, r = 0.82; and with body height: LV mass = 262 +/- 5.9 body height, r = 0.75. Normal limits were developed for these relationships. NMRI-determined LV mass as related to body weight was in agreement with normal limits derived from autopsy literature data.(ABSTRACT TRUNCATED AT 250 WORDS)
Tulley, Richard T; Appel, Marko J; Enos, Tanya G; Hegsted, Maren; McCutcheon, Kathleen L; Zhou, Jun; Raggio, Anne M; Jeffcoat, Roger; Birkett, Anne; Martin, Roy J; Keenan, Michael J
2009-09-23
Energy values of high amylose corn starches high in resistant starch (RS) were determined in vivo by two different methodologies. In one study, energy values were determined according to growth relative to glucose-based diets in rats fed diets containing RS(2), heat-treated RS(2) (RS(2)-HT), RS(3), and amylase predigested versions to isolate the RS component. Net metabolizable energy values ranged from 2.68 to 3.06 kcal/g for the RS starches, and 1.91-2.53 kcal/g for the amylase predigested versions. In a second study, rats were fed a diet containing RS(2)-HT and the metabolizable energy value was determined by bomb calorimetry. The metabolizable energy value was 2.80 kcal/g, consistent with Study 1. Thus, high amylose corn based RS ingredients and their amylase predigested equivalents have energy values approximately 65-78% and 47-62% of available starch (Atwater factor), respectively, according to the RS type (Garcia, T. A.; McCutcheon, K. L.; Francis, A. R.; Keenan, M. J.; O'Neil, C. E.; Martin, R. J.; Hegsted, M. The effects of resistant starch on gastrointestinal organs and fecal output in rats. FASEB J. 2003, 17, A335).
van Zelm, Rosalie; Stam, Gea; Huijbregts, Mark A J; van de Meent, Dik
2013-01-01
Freshwater fate and exposure factors were determined for organic acids and bases, making use of the knowledge on electrical interaction of ionizing chemicals and their sorption to particles. The fate factor represents the residence time in the environment whereas exposure factors equal the dissolved fraction of a chemical. Multimedia fate, exposure, and effect model USES-LCA was updated to take into account the influence of ionization, based upon the acid dissociation constant (pK(a)) of a chemical, and the environmental pH. Freshwater fate (FF) and exposure (XF) factors were determined for 415 acids and 496 bases emitted to freshwater, air, and soil. The relevance of taking account of the degree of ionization of chemicals was tested by determining the ratio (R) of the new vs. fate and exposure factors determined with USES-LCA suitable for neutral chemicals only. Our results show that the majority of freshwater fate and exposure factors of chemicals that are largely ionized in the environment are larger with the ionics model compared to the factors determined with the neutrals model version. R(FF) ranged from 2.4×10(-1) to 1.6×10(1) for freshwater emissions, from 1.2×10(-2) to 2.0×10(4) for soil emissions and from 5.8×10(-2) to 6.0×10(3) for air emissions, and R(XF) from 5.3×10(-1) to 2.2×10(1). Prediction of changed solid-water partitioning, implying a change in runoff and in removal via sedimentation, and prediction of negligible air-water partition coefficient, leading to negligible volatilization were the main contributors to the changes in freshwater fate factors. Copyright © 2012 Elsevier Ltd. All rights reserved.
Nardo, Luciano G; Christodoulou, Dimitra; Gould, Della; Roberts, Steve A; Fitzgerald, Cheryl T; Laing, Ian
2007-01-01
The aims of this prospective study were to investigate the relationship between anti-Müllerian hormone (AMH) and antral follicle count (AFC), and to determine whether these markers of ovarian reserve correlate with lifestyle factors, ethnicity, chronological age and reproductive history. Participants were 136 normo-ovulatory women undergoing infertility work-up within 3 months of their first ovarian stimulation cycle for in vitro fertilization. On day 3 of a spontaneous menstrual cycle, a blood sample for measurement of plasma AMH levels was taken and a transvaginal ultrasound scan to determine the AFC (follicles measuring 2-5 mm in diameter) was performed. Information about smoking, body mass index, alcohol consumption, ethnic origin, chronological age, age at menarche, years since menarche and gravidity were recorded using a case report form. The main outcome measures were plasma AMH concentrations and total number of small antral follicles (AFC). Median plasma levels of AMH were 2.0 ng/ml (interquartile range 1.1-3.6) and AFC was 10 (interquartile range 7-15). A positive correlation between AMH and AFC (r = 0.54, p < 0.0001) was found. AMH and AFC correlated negatively with age (r = -0.30, p < 0.001 and r = -0.27, p = 0.001 respectively) and number of years since menarche (r = -0.23, p = 0.007 and r = -0.21, p = 0.015 respectively), but not with any of the other measures. Circulating AMH levels and AFC correlated with each other and declined significantly with age. There were only weak, non-significant, correlations with lifestyle factors and reproductive history. These putative markers could be used individually or together to assess the age-related decline of ovarian function in normo-ovulatory candidates for IVF.
Tejero, Sergio; Cejudo, Pilar; Quintana-Gallego, E; Sañudo, Borja; Oliva-Pascual-Vaca, A
2016-03-18
Nutritional status and daily physical activity (PA) may be an excellent tool for the maintenance of bone health in patients with cystic fibrosis (CF). To evaluate the relationship between nutritional status, daily physical activity and bone turnover in cystic fibrosis patients. A cross-sectional study of adolescent and adult patients diagnosed with clinically stable cystic fibrosis was conducted. Total body, femoral neck, and lumbar spine bone mineral density (BMD) were determined by dual energy X-ray absorptiometry and bone metabolism markers ALP, P1NP, PICP, and ß-CrossLaps. PA monitoring was assessed for 5 consecutive days using a portable device. Exercise capacity was also determined. Serum 25-hydroxyvitamin D and vitamin K were also determined in all participants. Fifty patients (median age: 24.4 years; range: 16-46) were included. BMI had positive correlation with all BMD parameters, with Spearman's coefficients ranging from 0.31 to 0.47. Total hip bone mineral density and femoral neck BMD had positive correlation with the daily time spent on moderate PA (>4.8 metabolic equivalent-minutes/day; r=0.74, p<0.001 and r=0.72 p<0.001 respectively), daily time spent on vigorous PA (>7.2 metabolic equivalent-minutes/day; r=0.45 p<0.001), body mass index (r=0.44, p=0.001), and muscle mass in limbs (r=0.41, p=0.004). Levels of carboxy-terminal propeptide of type 1 collagen were positively associated with the daily time spent on moderate (r=0.33 p=0.023) and vigorous PA (r=0.53, p<0.001). BMI and the daily time spent on moderate PA were found to be correlated with femoral neck BMD in CF patients. The association between daily PA and biochemical markers of bone formation suggests that the level of daily PA may be linked to bone health in this patient group. Further research is needed to confirm these findings.
Tsai, Chia-Ju; Li, Jih-Heng; Feng, Chia-Hsien
2015-09-04
A novel, simple and quick sample preparation method was developed and used for pre-concentration and extraction of six phenylpropenes, including anethole, estragole, eugenol, methyl eugenol, safrole and myristicin, from oil samples by dual dispersive liquid-liquid microextraction. Gas chromatography-mass spectrometry was used for determination and separation of compounds. Several experimental parameters affecting extraction efficiency were evaluated and optimized, including forward-extractant type and volume, surfactant type and concentration, water volume, and back-extractant type and volume. For all analytes (10-1000ng/mL), the limits of detection (S/N≧3) ranged from 1.0 to 3.0ng/mL; the limits of quantification (S/N≧10) ranged from 2.5 to 10.0ng/mL; and enrichment factors ranged from 3.2 to 37.1 times. Within-run and between-run relative standard deviations (n=6) were less than 2.61% and less than 4.33%, respectively. Linearity was excellent with determination coefficients (r(2)) above 0.9977. The experiments showed that the proposed method is a simple, effective, and environmentally friendly method of analyzing phenylpropenes in oil samples. Copyright © 2015 Elsevier B.V. All rights reserved.
Wu, Ching-Chou; Lin, Chia-Hung; Wang, Way-Shyan
2009-06-30
Enrofloxacin is the most widespread antibiotic in the fluoroquinolone family. As such, the development of a rapid and sensitive method for the determination of trace amounts of enrofloxacin is an important issue in the health field. The interaction of the enrofloxacin antigen to a specific antibody (Ab) immobilized on an 11-mercapto-undecanoic acid-coated gold electrode was quantified by electrochemical impedance spectroscopy. Two equivalent circuits were separately used to interpret the obtained impedance spectra. These circuits included one resistor in series with one parallel circuit comprised of a resistor and a capacitor (1R//C), and one resistor in series with two parallel RC circuits (2R//C). The results indicate that the antigen-antibody reaction analyzed using the 1R//C circuit provided a more sensitive resistance increment against the enrofloxacin concentration than that of the 2R//C circuit. However, the 2R//C circuit provided a better fitting for impedance spectra, and therefore supplies more detailed results of the enrofloxacin-antibody interaction, causing the increase of electron transfer resistance selectively to the modified layer, and not the electrical double layer. The antibody-modified electrode allowed for analysis of the dynamic linear range of 1-1000 ng/ml enrofloxacin with a detection limit of 1 ng/ml. The reagentless and label-free impedimetric immunosensors provide a simple and sensitive detection method for the specific determination of enrofloxacin.
NASA Astrophysics Data System (ADS)
Saunders, Ian; Ottemöller, Lars; Brandt, Martin B. C.; Fourie, Christoffel J. S.
2013-04-01
A relation to determine local magnitude ( M L) based on the original Richter definition is empirically derived from synthetic Wood-Anderson seismograms recorded by the South African National Seismograph Network. In total, 263 earthquakes in the distance range 10 to 1,000 km, representing 1,681 trace amplitudes measured in nanometers from synthesized Wood-Anderson records on the vertical channel were considered to derive an attenuation relation appropriate for South Africa through multiple regression analysis. Additionally, station corrections were determined for 26 stations during the regression analysis resulting in values ranging between -0.31 and 0.50. The most appropriate M L scale for South Africa from this study satisfies the equation: {M_{{{L}}}} = {{lo}}{{{g}}_{{10}}}(A) + 1.149{{lo}}{{{g}}_{{10}}}(R) + 0.00063R + 2.04 - S The anelastic attenuation term derived from this study indicates that ground motion attenuation is significantly different from Southern California but comparable with stable continental regions.
Patient-specific dose calculations for pediatric CT of the chest, abdomen and pelvis
Fraser, Nicholas D.; Carver, Diana E.; Pickens, David R.; Price, Ronald R.; Hernanz-Schulman, Marta; Stabin, Michael G.
2015-01-01
Background Organ dose is essential for accurate estimates of patient dose from CT. Objective To determine organ doses from a broad range of pediatric patients undergoing diagnostic chest–abdomen–pelvis CT and investigate how these relate to patient size. Materials and methods We used a previously validated Monte Carlo simulation model of a Philips Brilliance 64 multi-detector CT scanner (Philips Healthcare, Best, The Netherlands) to calculate organ doses for 40 pediatric patients (M:F=21:19; range 0.6–17 years). Organ volumes and positions were determined from the images using standard segmentation techniques. Non-linear regression was performed to determine the relationship between volume CT dose index (CTDIvol)-normalized organ doses and abdominopelvic diameter. We then compared results with values obtained from independent studies. Results We found that CTDIvol-normalized organ dose correlated strongly with exponentially decreasing abdominopelvic diameter (R2>0.8 for most organs). A similar relationship was determined for effective dose when normalized by dose-length product (R2=0.95). Our results agreed with previous studies within 12% using similar scan parameters (i.e. bowtie filter size, beam collimation); however results varied up to 25% when compared to studies using different bowtie filters. Conclusion Our study determined that organ doses can be estimated from measurements of patient size, namely body diameter, and CTDIvol prior to CT examination. This information provides an improved method for patient dose estimation. PMID:26142256
Bonfilio, Rudy; Tarley, César Ricardo Teixeira; Pereira, Gislaine Ribeiro; Salgado, Hérida Regina Nunes; de Araújo, Magali Benjamim
2009-11-15
This paper describes the optimization and validation of an analytical methodology for the determination of losartan potassium in capsules by HPLC using 2(5-1) fractional factorial and Doehlert designs. This multivariate approach allows a considerable improvement in chromatographic performance using fewer experiments, without additional cost for columns or other equipment. The HPLC method utilized potassium phosphate buffer (pH 6.2; 58 mmol L(-1))-acetonitrile (65:35, v/v) as the mobile phase, pumped at a flow rate of 1.0 mL min(-1). An octylsilane column (100 mm x 4.6mm i.d., 5 microm) maintained at 35 degrees C was used as the stationary phase. UV detection was performed at 254 nm. The method was validated according to the ICH guidelines, showing accuracy, precision (intra-day relative standard deviation (R.S.D.) and inter-day R.S.D values <2.0%), selectivity, robustness and linearity (r=0.9998) over a concentration range from 30 to 70 mg L(-1) of losartan potassium. The limits of detection and quantification were 0.114 and 0.420 mg L(-1), respectively. The validated method may be used to quantify losartan potassium in capsules and to determine the stability of this drug.
Yu, Xue-Chun; He, Ke-Bin; Ma, Yong-Liang; Yang, Fu-Mo; Duan, Feng-Kui; Zheng, Ai-Hua; Zhao, Cheng-Yi
2004-01-01
A simple, sensitive and convenient ion chromatography(IC) method was established for the simultaneous determination of twelve water-soluble inorganic anions(F- , Cl- , NO2(-), NO3(-), SO3(2-), SO4(2-) , PO4(3-)), and fifteen water-soluble organic ions(formate, acetate, MSA, oxalate, malonate, succinate, phthalates, etc.) in atmospheric aerosols. The linear concentrations ranged from 0.005 microg/m3 to 500 microg/m3 ( r = 0.999-0.9999). The relative standard deviation (RSD) were 0.43%-2.00% and the detection limits were from 2.7 ng/m3 to 88 ng/m3. The proposed method was successfully applied to the simultaneous determination of those inorganic ions and organic ions in PM2.5 of Beijing.
NASA Astrophysics Data System (ADS)
Balidoy Baloloy, Alvin; Conferido Blanco, Ariel; Gumbao Candido, Christian; Labadisos Argamosa, Reginal Jay; Lovern Caboboy Dumalag, John Bart; Carandang Dimapilis, Lee, , Lady; Camero Paringit, Enrico
2018-04-01
Aboveground biomass estimation (AGB) is essential in determining the environmental and economic values of mangrove forests. Biomass prediction models can be developed through integration of remote sensing, field data and statistical models. This study aims to assess and compare the biomass predictor potential of multispectral bands, vegetation indices and biophysical variables that can be derived from three optical satellite systems: the Sentinel-2 with 10 m, 20 m and 60 m resolution; RapidEye with 5m resolution and PlanetScope with 3m ground resolution. Field data for biomass were collected from a Rhizophoraceae-dominated mangrove forest in Masinloc, Zambales, Philippines where 30 test plots (1.2 ha) and 5 validation plots (0.2 ha) were established. Prior to the generation of indices, images from the three satellite systems were pre-processed using atmospheric correction tools in SNAP (Sentinel-2), ENVI (RapidEye) and python (PlanetScope). The major predictor bands tested are Blue, Green and Red, which are present in the three systems; and Red-edge band from Sentinel-2 and Rapideye. The tested vegetation index predictors are Normalized Differenced Vegetation Index (NDVI), Soil-adjusted Vegetation Index (SAVI), Green-NDVI (GNDVI), Simple Ratio (SR), and Red-edge Simple Ratio (SRre). The study generated prediction models through conventional linear regression and multivariate regression. Higher coefficient of determination (r2) values were obtained using multispectral band predictors for Sentinel-2 (r2 = 0.89) and Planetscope (r2 = 0.80); and vegetation indices for RapidEye (r2 = 0.92). Multivariate Adaptive Regression Spline (MARS) models performed better than the linear regression models with r2 ranging from 0.62 to 0.92. Based on the r2 and root-mean-square errors (RMSE's), the best biomass prediction model per satellite were chosen and maps were generated. The accuracy of predicted biomass maps were high for both Sentinel-2 (r2 = 0.92) and RapidEye data (r2 = 0.91).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Teja, A.S.; King, R.K.; Sun, T.F.
1999-01-01
Two methods are presented for the correlation and prediction of the viscosities and thermal conductivities of refrigerants R11, R12, R22, R32, R124, R125, R134a, R141b, and R152 and their mixtures. The first (termed RHS1) is a modified rough-hard-sphere method based on the smooth hard-sphere correlations of Assael et al. The method requires two or three parameters for characterizing each refrigerant but is able to correlate transport properties over wide ranges of pressure and temperature. The second method (RHS2) is also a modified rough-hard-sphere method, but based on an effective hard-sphere diameter for Lennard-Jones (LJ) fluids. The LJ parameters and themore » effective hard-sphere diameter required in this method are determined from a knowledge of the density-temperature behavior of the fluid at saturation. Comparisons with the rough-hard-sphere method of Assael and co-workers (RHS3) are shown. They also show that the RHS2 method can be used to correlate as well as predict the transport properties of refrigerants.« less
Sichilongo, Kwenga; Chinyama, Mompati; Massele, Amos; Vento, Sandro
2014-01-15
A contrast between the analytical performance characteristics using gas chromatography-mass spectrometry (GC-MS) liquid chromatography-mass spectrometry (LC-MS) and liquid chromatography-ultraviolet (LC-UV) detection for the determination of the antiretroviral drug (ARV) nevirapine (NVP) in fortified human plasma after QuEChERS extraction has been made. Analytical performance characteristics, i.e. linearities, instrument detection limits (IDLs), limits of quantitation (LOQs), method detection limits (MDLs), % mean recoveries and the corresponding relative standard deviations (%RSDs) were estimated using techniques above. Using GC-MS, the correlation coefficients (r(2)) were ≥0.990, which were deemed acceptable linearities. The MDLs ranged between 11.1-29.8μg/L and 13.7-36.0μg/L using helium and hydrogen carrier gases respectively. The LOQs ranged between 16.5-66.7μg/L and 28.4-98.7μg/L using helium and hydrogen carrier gases respectively with a % mean recovery of 83% and %RSD of 4.6%. Using LC-MS and LC-UV, the correlation coefficients (r(2)) were ≥0.990. The MDLs were ranged between 3.14 and 47.1μg/L. The LOQs ranged between 2.85 and 90.0μg/L respectively. The MDLs using GC-MS, LC-MS and LC-UV were below the therapeutic range for NVP in human plasma is considered to be between 2300μg/L (Cmin) and 8000μg/L (Cmax). This study also demonstrated that helium can be substituted with hydrogen which is relatively cheaper and easily obtainable even by use of a generator. Copyright © 2013 Elsevier B.V. All rights reserved.
Thiex, Nancy J
2016-07-01
A previously validated method for the determination of both citrate-EDTA-soluble P and K and acid-soluble P and K in commercial inorganic fertilizers by inductively coupled plasma-optical emission spectrometry was submitted to the expert review panel (ERP) for fertilizers for consideration of First Action Official Method(SM) status. The ERP evaluated the single-laboratory validation results and recommended the method for First Action Official Method status and provided recommendations for achieving Final Action. Validation materials ranging from 4.4 to 52.4% P2O5 (1.7-22.7% P) and 3-62% K2O (2.5-51.1% K) were used for the validation. Recoveries from validation materials for citrate-soluble P and K ranged from 99.3 to 124.9% P and from 98.4 to 100.7% K. Recoveries from validation materials for acid-soluble "total" P and K ranged from 95.53 to 99.40% P and from 98.36 to 107.28% K. Values of r for citrate-soluble P and K, expressed as RSD, ranged from 0.28 to 1.30% for P and from 0.41 to 1.52% for K. Values of r for total P and K, expressed as RSD, ranged from 0.71 to 1.13% for P and from 0.39 to 1.18% for K. Based on the validation data, the ERP recommended the method (with alternatives for the citrate-soluble and the acid-soluble extractions) for First Action Official Method status and provided recommendations for achieving Final Action status.
Fernández-Novales, Juan; López, María-Isabel; González-Caballero, Virginia; Ramírez, Pilar; Sánchez, María-Teresa
2011-06-01
Volumic mass-a key component of must quality control tests during alcoholic fermentation-is of great interest to the winemaking industry. Transmitance near-infrared (NIR) spectra of 124 must samples over the range of 200-1,100-nm were obtained using a miniature spectrometer. The performance of this instrument to predict volumic mass was evaluated using partial least squares (PLS) regression and multiple linear regression (MLR). The validation statistics coefficient of determination (r(2)) and the standard error of prediction (SEP) were r(2) = 0.98, n = 31 and r(2) = 0.96, n = 31, and SEP = 5.85 and 7.49 g/dm(3) for PLS and MLR equations developed to fit reference data for volumic mass and spectral data. Comparison of results from MLR and PLS demonstrates that a MLR model with six significant wavelengths (P < 0.05) fit volumic mass data to transmittance (1/T) data slightly worse than a more sophisticated PLS model using the full scanning range. The results suggest that NIR spectroscopy is a suitable technique for predicting volumic mass during alcoholic fermentation, and that a low-cost NIR instrument can be used for this purpose.
Silva, Claudineia R; Vieira, Heberth J; Canaes, Larissa S; Nóbrega, Joaquim A; Fatibello-Filho, Orlando
2005-02-28
A flow injection (FI) spectrophotometric method was proposed for the determination of chloride ion in natural waters. The determination of chloride was carried out by reaction with Hg(SCN)(2) immobilized in an epoxy resin bead in a solid-phase reactor (SPR) and the thiocyanate ions released were determined spectrophotometrically at 480nm after complexing reaction with Fe(III). The analytical curve for chloride was linear in the concentration range from 5.6 x 10(-5) to 2.2 x 10(-4)moll(-1) with a detection limit of 1.4 x 10(-5)moll(-1). The relative standard deviation (R.S.D.) was 2.2% for a solution containing 2.2 x 10(-4)moll(-1) (n = 10). The simple manifold allows a routine analytical frequency of 100 determinations per hour. The main advantage of the developed method is the 400% reduction of the Hg waste solution generated when compared to conventional methods for chloride determination based on the same spectrophotometric reaction.
Experimental validation of a T2 ρ transverse relaxation model using LASER and CPMG acquisitions
NASA Astrophysics Data System (ADS)
Nikolova, Simona; Bowen, Chris V.; Bartha, Robert
2006-07-01
The transverse relaxation rate (R2 = 1/T2) of many biological tissues are altered by endogenous magnetized particles (i.e., ferritin, deoxyhemoglobin), and may be sensitive to the pathological progression of neurodegenerative disorders associated with altered brain-iron stores. R2 measurements using Carr-Purcell-Meiboom-Gill (CPMG) acquisitions are sensitive to the refocusing pulse interval (2τcp), and have been modeled as a chemical exchange (CE) process, while R2 measurements using a localization by adiabatic selective refocusing (LASER) sequence have an additional relaxation rate contribution that has been modeled as a R2ρ process. However, no direct comparison of the R2 measured using these two sequences has been described for a controlled phantom model of magnetized particles. The three main objectives of this study were: (1) to compare the accuracy of R2 relaxation rate predictions from the CE model with experimental data acquired using a conventional CPMG sequence, (2) to compare R2 estimates obtained using LASER and CPMG acquisitions, and (3) to determine whether the CE model, modified to account for R2ρ relaxation, adequately describes the R2 measured by LASER for a full range of τcp values. In all cases, our analysis was confined to spherical magnetic particles that satisfied the weak field regime. Three phantoms were produced that contained spherical magnetic particles (10 μm diameter polyamide powders) suspended in Gd-DTPA (1.0, 1.5, and 2.0 mmol/L) doped gel. Mono-exponential R2 measurements were made at 4 T as a function of refocusing pulse interval. CPMG measurements of R2 agreed with CE model predictions while significant differences in R2 estimates were observed between LASER and CPMG measurements for short τcp acquisitions. The discrepancy between R2 estimates is shown to be attributable to contrast enhancement in LASER due to T2ρ relaxation.
Ateş, Filiz; Hug, François; Bouillard, Killian; Jubeau, Marc; Frappart, Thomas; Couade, Mathieu; Bercoff, Jeremy; Nordez, Antoine
2015-08-01
Muscle shear elastic modulus is linearly related to muscle torque during low-level contractions (<60% of Maximal Voluntary Contraction, MVC). This measurement can therefore be used to estimate changes in individual muscle force. However, it is not known if this relationship remains valid for higher intensities. The aim of this study was to determine: (i) the relationship between muscle shear elastic modulus and muscle torque over the entire range of isometric contraction and (ii) the influence of the size of the region of interest (ROI) used to average the shear modulus value. Ten healthy males performed two incremental isometric little finger abductions. The joint torque produced by Abductor Digiti Minimi was considered as an index of muscle torque and elastic modulus. A high coefficient of determination (R(2)) (range: 0.86-0.98) indicated that the relationship between elastic modulus and torque can be accurately modeled by a linear regression over the entire range (0% to 100% of MVC). The changes in shear elastic modulus as a function of torque were highly repeatable. Lower R(2) values (0.89±0.13 for 1/16 of ROI) and significantly increased absolute errors were observed when the shear elastic modulus was averaged over smaller ROI, half, 1/4 and 1/16 of the full ROI) than the full ROI (mean size: 1.18±0.24cm(2)). It suggests that the ROI should be as large as possible for accurate measurement of muscle shear modulus. Copyright © 2015 Elsevier Ltd. All rights reserved.
High temperature pyrolysis of vinylacetylene
NASA Astrophysics Data System (ADS)
Braun-Unkhoff, M.; Kurz, A.; Frank, P.
1990-07-01
The thermal decomposition of vinylacetylene has been studied behind reflected shock waves in the temperature range 1350-1870 K at total pressures between 1.7 and 7.4 bar. Initial concentrations of the hydrogen in argon ranged between 1 to 300 ppm. The following species were measured: H-atoms by ARAS, C2H2, C4H2 and C4H4 by molecular vuv-absorption. The combination of very low initial concentrations with a sensitive detection technique allowed to perform the experiments under conditions where only very few elementary reaction steps determine the progress of reaction. It was found that C4H4 decomposes simultaneously into different product channels: C4H4→C2H2+C2H2 k1a=3.4ṡ1013 exp(-38820/T) s-1 C4H4+Ar→C4H3+H+Ar k1b=1.1ṡ1020exp(-49990/T) cm3 mol-1 s-1 C4H4→C4H2+H2 k1c=1.3ṡ1015exp(-47670/T) s-1. From variation of the total pressure it has been deduced that reaction pathways R1a and R1c proceed with rates not far from the high-pressure limiting values and that reaction R1b proceeds close to the low-pressure limiting rate constant values.
Kasawar, G B; Farooqui, M N
2009-09-01
A chiral reverse phase liquid chromatographic method was developed for the enantiomeric resolution of racemic mixture of (-)-5-[2-aminopropyl]-2-methoxybenzene sulfonamide in bulk drug. The enantiomeric separation of sulfonamide was resolved on a Crownpak CR (+) column using perchloric acid buffer of pH 1.0 as mobile phase and with UV detection at 226 nm. The method is validated and proved to be robust. The limit of detection and quantification of S (-)-(5)-[2-aminopropyl]-2-methoxybenzene sulfonamide] was found to be 0.084 and 0.159 mug/ml, respectively for 20 mul injection volume. The percentage recovery of S (-)-(5)-[2-aminopropyl]-2-methoxybenzene sulfonamide] ranged from 99.57 to 101.88 in bulk drug samples of R (-)-(5)-[2- aminopropyl]-2-methoxybenzene sulfonamide].
Kasawar, G. B.; Farooqui, M. N.
2009-01-01
A chiral reverse phase liquid chromatographic method was developed for the enantiomeric resolution of racemic mixture of (-)-5-[2-aminopropyl]-2-methoxybenzene sulfonamide in bulk drug. The enantiomeric separation of sulfonamide was resolved on a Crownpak CR (+) column using perchloric acid buffer of pH 1.0 as mobile phase and with UV detection at 226 nm. The method is validated and proved to be robust. The limit of detection and quantification of S (-)-(5)-[2-aminopropyl]-2-methoxybenzene sulfonamide] was found to be 0.084 and 0.159 μg/ml, respectively for 20 μl injection volume. The percentage recovery of S (-)-(5)-[2-aminopropyl]-2-methoxybenzene sulfonamide] ranged from 99.57 to 101.88 in bulk drug samples of R (-)-(5)-[2- aminopropyl]-2-methoxybenzene sulfonamide]. PMID:20502572
Schabel, M C; Roberts, V H J; Lo, J O; Platt, S; Grant, K A; Frias, A E; Kroenke, C D
2016-11-01
To characterize spatial patterns of T2* in the placenta of the rhesus macaque (Macaca mulatta), to correlate these patterns with placental perfusion determined using dynamic contrast-enhanced MRI (DCE-MRI), and to evaluate the potential for using the blood oxygen level-dependent effect to quantify placental perfusion without the use of exogenous contrast reagent. MRI was performed on three pregnant rhesus macaques at gestational day 110. Multiecho spoiled gradient echo measurements were used to compute maps of T2*. Spatial maxima in these maps were compared with foci of early enhancement determined by DCE-MRI. Local maxima in T2* maps were strongly correlated with spiral arteries identified by DCE-MRI, with mean spatial separations ranging from 2.34 to 6.11 mm in the three animals studied. Spatial patterns of R2* ( = 1/ T2*) within individual placental lobules can be quantitatively analyzed using a simple model to estimate fetal arterial oxyhemoglobin concentration [Hbo,f] and a parameter viPS/Φ, reflecting oxygen transport to the fetus. Estimated mean values of [Hbo,f] ranged from 4.25 mM to 4.46 mM, whereas viPS/Φ ranged from 2.80 × 10 5 cm -3 to 1.61 × 10 6 cm -3 . Maternal spiral arteries show strong spatial correlation with foci of extended T2* observed in the primate placenta. A simple model of oxygen transport accurately describes the spatial dependence of R2* within placental lobules and enables assessment of placental function and oxygenation without requiring administration of an exogenous contrast reagent. Magn Reson Med 76:1551-1562, 2016. © 2015 International Society for Magnetic Resonance in Medicine. © 2015 International Society for Magnetic Resonance in Medicine.
A Summary of the Results of a Study of Acoustic Bottom Interaction in a Range Dependent Environment.
1980-11-14
8217 X4v~;i~Q2 \\ ’.X-C 0 fn 0K I ’ ........ .Y A J..~ a~ ~~A’, ~ l ~If U.- A4 UNCLASSIFIED SECURITY CLASSIFICATION OF THIS PAGE (When Date Entered) REPORT...Propagation Loss versus Range for Bottom Slopes of 1 and 30 50 111.15 Downslope Propagation Loss versus Range for Bottom Slopes of l and 30 52 111.16...given by l (z,r;zo,r) = 10 logIip (z,r) 12 (2.11) i1 In Eq. (2.11) I is the propagation loss between the field point (z,r) and a point source at (zo,r
Methane production in ruminants: Its effect on the doubly labeled water method
DOE Office of Scientific and Technical Information (OSTI.GOV)
Midwood, A.J.; Haggarty, P.; McGaw, B.A.
1989-12-01
The doubly labeled water (DLW) technique for measuring CO2 production (rCO2) in free-living animals requires an assessment of the elimination of both 2H and 18O from the body over a long period of time. To calculate rCO2, it is necessary to calculate water turnover (rH2O) from the 2H flux rate. In ruminant animals, the accuracy of this calculation is affected by the loss of 2H in methane. We have quantified the effect of methane production (rCH4) on the 2H flux rate, determined in four sheep given 2H2O. The methane produced was depleted in 2H relative to the urine. A relationshipmore » between the enrichment of the methane and urine was established. The ratio of urine to methane enrichment was found on average to be 0.6536, and this value was unaffected by the level of rCH4 but showed some dependence on the absolute concentration of 2H in urine. For this reason, the ratio value obtained from four sheep not given 2H2O was different, a mean of 0.6886 was measured, this ratio was unaffected by changes in the diet supplied to the animals. Computer modeling was used to illustrate the dependence of the isotopically derived value for rCO2 on not only rCH4 but also the magnitude of rCO2 itself. The effect of rCH4 on the DLW method can be predicted from the observed ratio of rCO2 to rCH4 and the value of 0.6536 obtained for the ratio of methane to urine enrichment. With the use of data from several studies at this Institute, a limited range of 10 to 20 was found for rCO2/rCH4 in animals fed at or above maintenance.« less
Shim, You-Shin; Yoon, Won-Jin; Hwang, Jin-Bong; Park, Hyun-Jin; Seo, Dongwon; Ha, Jaeho
2015-11-15
A rapid method for the determination of 14 types of isoflavones in food using ultra-high performance liquid chromatography (UHPLC) was validated in terms of precision, accuracy, sensitivity and linearity. The UHPLC separation was performed on a reverse-phase C18 column (particle size 2 μm, i.d. 2 mm, length 100 mm) using a photo diode array detector that was fixed to 260 nm. The limits of detection and quantification of the UHPLC analyses ranged from 0.03 to 0.33 mg kg(-1). The intra-day and inter-day precision of the individual isoflavones were less than 11.77% and calibration curves exhibited good linearity (r(2) = 0.99) within the tested ranges. These results suggest that the rapid method used in this study could be available to determine of 14 types of isoflavones in a variety of food such as soy bean, black bean, red bean and soybean paste. Copyright © 2015 Elsevier Ltd. All rights reserved.
Investigation of the PAGAT polymer gel dosimeter using magnetic resonance imaging
NASA Astrophysics Data System (ADS)
Venning, A. J.; Hill, B.; Brindha, S.; Healy, B. J.; Baldock, C.
2005-08-01
Investigation of the normoxic PAGAT polymer gel dosimeter has been undertaken. The concentrations of the chemical components of the gel were varied and its response to ionizing radiation evaluated. Using MRI, the formulation to give the maximum change in the transverse relaxation rate R2 was determined to be 4.5% N, N'-methylene-bis-acrylamide (bis), 4.5% acrylamide (AA), 5% gelatine, 5 mM tetrakis (hydroxymethyl) phosphonium chloride (THPC), 0.01 mM hydroquinone (HQ) and 86% H2O. The optimal post-manufacture irradiation and post-irradiation imaging times were both determined to be 12 h. The R2-dose response was linear up to 7 Gy with R2-dose sensitivities of (0.183 ± 0.005) s-1 Gy-1, (0.182 ± 0.005) s-1 Gy-1 and (0.192 ± 0.005) s-1 Gy-1 when imaged at 12 h, 7 days and 24 days post-irradiation, respectively. The R2-dose sensitivities were within the range of previously published values for the hypoxic PAG formulations. For the imaging parameters used in this study the optimum dose resolution was achieved for low doses. The normalized R2 edge response showed a high degree of spatial stability over a 24 day period. This study has shown that the normoxic PAGAT polymer gel has the properties of a dosimetric tool, which can be used in clinical radiotherapy. The PAGAT polymer gel has been shown to have similar qualities to the PAG polymer gel, while offering the significant advantage of simplification of the manufacturing procedure.
Eryılmaz, Gul; Sayar, Gökben Hızlı; Özten, Eylem; Gül, Işıl Göğcegöz; Yorbik, Özgür; Işiten, Nuket; Bağcı, Eda
2015-06-01
The purpose of this study is to determine the impact of repetitive transcranial stimulation (rTMS) treatment during pregnancy on neurodevelopment of children. Women who were treated with rTMS during pregnancy and delivered liveborn children between 2008 and 2013 were selected. A control group consisted of children whose mothers had a history of untreated depression during their pregnancy (N = 26). Early developmental characteristics of all the children in the study were evaluated, and their developmental levels were determined using the Ankara Developmental Screening Inventory. The mean age of the children in the rTMS treatment group was 32.4 months (range 16-64 months), and that of the untreated group was 29.04 (range 14-63 months). Jaundice (N = 2) and febrile convulsion (N = 1) were the reported medical conditions in the children of the rTMS-treated group; jaundice (N = 3) and low birth weight (N = 1) were reported in the untreated group. In the rTMS group, mothers' perception of delay in language development was observed, but there were not any statistically significant differences in the prevalence rate compared with the untreated group (OR = 0.38; 95% CI 0.0860-1.6580). Our results suggest that rTMS exposure during pregnancy is not associated with poorer cognitive or motor development outcomes in children aged 18-62 months. Although language development as reported by the mothers was found to be poorer than expected in the rTMS-treated group, the delay was found to be similar to the language delay observed in offspring of untreated mothers, as reported in previous studies of prenatal depression treated with selective serotonin reuptake inhibitors. © 2014 International Neuromodulation Society.
Kuriki, Ayako; Kumazawa, Takeshi; Lee, Xiao-Pen; Hasegawa, Chika; Kawamura, Mitsuru; Suzuki, Osamu; Sato, Keizo
2006-12-05
A method for the simultaneous determination of selegiline and its metabolite, desmethylselegiline, in human whole blood and urine is presented. The method, which combines a fiber-based headspace solid-phase microextraction (SPME) technique with gas chromatography-mass spectrometry (GC-MS), required optimization of various parameters (e.g., salt additives, extraction temperatures, extraction times and the extraction properties of the SPME fiber coatings). Pargyline was used as the internal standard. Extraction efficiencies for both selegiline and desmethylselegiline were 2.0-3.4% for whole blood, and 8.0-13.2% for urine. The regression equations for selegiline and desmethylselegiline extracted from whole blood were linear (r(2)=0.996 and 0.995) within the concentration ranges 0.1-10 and 0.2-20 ng/ml, respectively. For urine, the regression equations for selegiline and desmethylselegiline were linear (r(2)=0.999 and 0.998) within the concentration ranges 0.05-5.0 and 0.1-10 ng/ml, respectively. The limit of detection for selegiline and desmethylselegiline was 0.01-0.05 ng/ml for both samples. The lower and upper limits of quantification for each compound were 0.05-0.2 and 5-20 ng/ml, respectively. Intra- and inter-day coefficients of variation for selegiline and desmethylselegiline in both samples were not greater than 8.7 and 11.7%, respectively. The determination of selegiline and desmethylselegiline concentrations in Parkinson's disease patients undergoing continuous selegiline treatment is presented and is shown to validate the present methodology.
Mines, Richard O; Callier, Matthew C; Drabek, Benjamin J; Butler, André J
2017-03-21
The proper design of aeration systems for bioreactors is critical since it can represent up to 50% of the operational and capital cost at water reclamation facilities. Transferring the actual amount of oxygen needed to meet the oxygen demand of the wastewater requires α- and β-factors, which are used for calculating the actual oxygen transfer rate (AOTR) under process conditions based on the standard oxygen transfer rate (SOTR). The SOTR is measured in tap water at 20°C, 1 atmospheric pressure, and 0 mg L -1 of dissolved oxygen (DO). In this investigation, two 11.4-L bench-scale completely mixed activated process (CMAS) reactors were operated at various solid retention times (SRTs) to ascertain the relationship between the α-factor and SRT, and between the β-factor and SRT. The second goal was to determine if actual oxygen uptake rates (AOURs) are equal to calculated oxygen uptake rates (COURs) based on mass balances. Each reactor was supplied with 0.84 L m -1 of air resulting in SOTRs of 14.3 and 11.5 g O 2 d -1 for Reactor 1 (R-1) and Reactor 2 (R-2), respectively. The estimated theoretical oxygen demands of the synthetic feed to R-1 and R-2 were 6.3 and 21.9 g O 2 d -1 , respectively. R-2 was primarily operated under a dissolved oxygen (DO) limitation and high nitrogen loading to determine if nitrification would be inhibited from a nitrite buildup and if this would impact the α-factor. Nitrite accumulated in R-2 at DO concentrations ranging from 0.50 to 7.35 mg L -1 and at free ammonia (FA) concentrations ranging from 1.34 to 7.19 mg L -1 . Nonsteady-state reaeration tests performed on the effluent from each reactor and on tap water indicated that the α-factor increased as SRT increased. A simple statistical analysis (paired t-test) between AOURs and COURs indicated that there was a statistically significant difference at 0.05 level of significance for both reactors. The ex situ BOD bottle method for estimating AOUR appears to be invalid in bioreactors operated at low DO concentrations (<1.0 mg L -1 ).
Park, Hee-Won; In, Gyo; Han, Sung-Tai; Lee, Myoung-Woo; Kim, So-Young; Kim, Kyung-Tack; Cho, Byung-Goo; Han, Gyeong-Ho; Chang, Il-Moo
2013-01-01
A quick and simple method for simultaneous determination of the 30 ginsenosides (ginsenoside Ro, Rb1, Rb2, Rc, Rd, Re, Rf, Rg1, 20(S)-Rg2, 20(R)-Rg2, 20(S)-Rg3, 20(R)-Rg3, 20(S)-Rh1, 20(S)-Rh2, 20(R)-Rh2, F1, F2, F4, Ra1, Rg6, Rh4, Rk3, Rg5, Rk1, Rb3, Rk2, Rh3, compound Y, compound K, and notoginsenoside R1) in Panax ginseng preparations was developed and validated by an ultra performance liquid chromatography photo diode array detector. The separation of the 30 ginsenosides was efficiently undertaken on the Acquity BEH C-18 column with gradient elution with phosphoric acids. Especially the chromatogram of the ginsenoside Ro was dramatically enhanced by adding phosphoric acid. Under optimized conditions, the detection limits were 0.4 to 1.7 mg/L and the calibration curves of the peak areas for the 30 ginsenosides were linear over three orders of magnitude with a correlation coefficients greater than 0.999. The accuracy of the method was tested by a recovery measurement of the spiked samples which yielded good results of 89% to 118%. From these overall results, the proposed method may be helpful in the development and quality of P. ginseng preparations because of its wide range of applications due to the simultaneous analysis of many kinds of ginsenosides. PMID:24235860
Li, Xin; Gao, Deli; Chen, Xuyue
2017-06-08
Hydraulic extended-reach limit (HERL) model of horizontal extended-reach well (ERW) can predict the maximum measured depth (MMD) of the horizontal ERW. The HERL refers to the well's MMD when drilling fluid cannot be normally circulated by drilling pump. Previous model analyzed the following two constraint conditions, drilling pump rated pressure and rated power. However, effects of the allowable range of drilling fluid flow rate (Q min ≤ Q ≤ Q max ) were not considered. In this study, three cases of HERL model are proposed according to the relationship between allowable range of drilling fluid flow rate and rated flow rate of drilling pump (Q r ). A horizontal ERW is analyzed to predict its HERL, especially its horizontal-section limit (L h ). Results show that when Q min ≤ Q r ≤ Q max (Case I), L h depends both on horizontal-section limit based on rated pump pressure (L h1 ) and horizontal-section limit based on rated pump power (L h2 ); when Q min < Q max < Q r (Case II), L h is exclusively controlled by L h1 ; while L h is only determined by L h2 when Q r < Q min < Q max (Case III). Furthermore, L h1 first increases and then decreases with the increase in drilling fluid flow rate, while L h2 keeps decreasing as the drilling fluid flow rate increases. The comprehensive model provides a more accurate prediction on HERL.
Asbestos-related diffuse pleural thickening.
Fujimoto, Nobukazu; Kato, Katsuya; Usami, Ikuji; Sakai, Fumikazu; Tokuyama, Takeshi; Hayashi, Seiji; Miyamoto, Kenji; Kishimoto, Takumi
2014-01-01
The clinical features of asbestos-related diffuse pleural thickening (DPT) remain unclear. To clarify the association between radiological findings of DPT and respiratory function. Medical data from patients with asbestos-related DPT were collected, including their history of occupational or neighborhood asbestos exposure, initial symptoms, modified Medical Research Council dyspnea grade, smoking history, radiological findings, and respiratory function test results. There were 106 DPT patients between 2005 and 2010 [i.e. 103 men (97.2%) and 3 women (2.8%)]. The median age at diagnosis was 69 years (range 46-88). Patient occupations related to asbestos exposure included: asbestos product manufacturing (n = 17); the shipbuilding industry (n = 14); the construction industry (n = 13); heat insulation work (n = 12); plumbing, asbestos spraying, and electrical work (n = 7 each), and transportation and demolition work (n = 4 each). The median duration of asbestos exposure was 25 years (range 2-54), and the median latency period before the onset of DPT was 46 years (range 25-66). Involvement of the costophrenic angle (CPA) was also negatively correlated with the percent vital capacity (%VC; r = -0.448, p < 0.01). Pleural thickness and the craniocaudal and horizontal extension of pleural thickening, as determined by chest computed tomography (CT), were also negatively correlated with %VC (r = -0.226, p < 0.05; r = -0.409, p < 0.01, and r = -0.408, p < 0.01, respectively). DPT develops after a long latency period following occupational asbestos exposure and causes marked respiratory dysfunction. The extension of DPT should be evaluated by chest CT, and chest X-ray would be important for the evaluation of the involvement of the CPA.
A 14 h {sup −3} Gpc{sup 3} study of cosmic homogeneity using BOSS DR12 quasar sample
DOE Office of Scientific and Technical Information (OSTI.GOV)
Laurent, Pierre; Goff, Jean-Marc Le; Burtin, Etienne
2016-11-01
The BOSS quasar sample is used to study cosmic homogeneity with a 3D survey in the redshift range 2.2 < z < 2.8. We measure the count-in-sphere, N (< r ), i.e. the average number of objects around a given object, and its logarithmic derivative, the fractal correlation dimension, D {sub 2}( r ). For a homogeneous distribution N (< r ) ∝ r {sup 3} and D {sub 2}( r ) = 3. Due to the uncertainty on tracer density evolution, 3D surveys can only probe homogeneity up to a redshift dependence, i.e. they probe so-called ''spatial isotropy'. Ourmore » data demonstrate spatial isotropy of the quasar distribution in the redshift range 2.2 < z < 2.8 in a model-independent way, independent of any FLRW fiducial cosmology, resulting in 3 − ( D {sub 2}) < 1.7 × 10{sup −3} (2 σ) over the range 250 < r < 1200 h {sup −1} Mpc for the quasar distribution. If we assume that quasars do not have a bias much less than unity, this implies spatial isotropy of the matter distribution on large scales. Then, combining with the Copernican principle, we finally get homogeneity of the matter distribution on large scales. Alternatively, using a flat ΛCDM fiducial cosmology with CMB-derived parameters, and measuring the quasar bias relative to this ΛCDM model, our data provide a consistency check of the model, in terms of how homogeneous the Universe is on different scales. D {sub 2}( r ) is found to be compatible with our ΛCDM model on the whole 10 < r < 1200 h {sup −1} Mpc range. For the matter distribution we obtain 3 − ( D {sub 2}) < 5 × 10{sup −5} (2 σ) over the range 250 < r < 1200 h {sup −1} Mpc, consistent with homogeneity on large scales.« less
Geochemical Interactions and Viral-Prokaryote Relationships in Freshwater Environments
NASA Astrophysics Data System (ADS)
Kyle, J. E.; Ferris, G.
2009-05-01
Viral and prokaryotic abundances were surveyed throughout southern Ontario aquatic habitats to determine relationships with geochemical parameters in the natural environment. Surface water samples were collected from acid mine drainage in summer of 2007 and 2008 and from circum-neutral pH environments in October to November 2008. Site determination was based on collecting samples from various aquatic habitats (acid mine drainage, lakes, rivers, tributaries, wetlands) with differing bedrock geology (limestone and shale dominated vs granitic Canadian Shield) to obtain a range of geochemical conditions. At each site, measurements of temperature, pH, and Eh were conducted. Samples collected for microbial counts and electron imaging were preserved to a final concentration of 2.5 % (v/v) glutaraldehyde. Additional sample were filtered into 60 mL nalgene bottles and amber EPA certified 40 mL glass vials to determine chemical constituents and dissolved organic carbon (DOC), respectively. Water was also collected to determine additional physiochemical parameters (dissolved total iron, ferric iron, nitrate, sulfate, phosphate, alkalinity, and turbidity). All samples were stored at 4 °C until analysis. Viral and prokaryotic abundance was determined by staining samples with SYBR Green I and examining with a epifluorescence microscope under blue excitation. Multiple regression analysis using stepwise backwards regression and general linear models revealed that viral abundance was the most influential predictor of prokaryotic abundance. Additional predictors include pH, sulfate, phosphate, and magnesium. The strength of the model was very strong with 90 % of the variability explained (R2 = 0.90, p < 0.007). This is the first report, to our knowledge, of viruses exhibiting such strong controls over prokaryotic abundance in the natural environment. All relationships are positively correlated with the exception of Mg, which is negatively correlated. Iron was also noted as a contributor to prokaryotic abundance but given the elements strong multicollinearity with sulfate, iron was removed from the model (as sulfate acts more conservatively across the range of pH sampled, 2.5-9.0). Geochemical variables that have been reported to influence viral abundances under laboratory and field experiments (i.e. Ca2+, DOC, temperature) had minimal effect in the natural environment despite 2 to 3 orders of magnitude range in the data. However, log transformed viral abundance did revealed a significant relationship with pH (Pearson correlation coefficient of r = 0.70) when using principle component analysis. Prokaryotic abundance did not reveal significant correlations with geochemical parameters (all r < 0.38).
The relationship between study strategies and academic performance.
Zhou, Yuanyuan; Graham, Lori; West, Courtney
2016-10-07
To investigate if and to what extent the Learning and Study Strategy Inventory (LASSI) and the Self-Directed Learning Readiness Scale (SDLRS) yield academic performance predictors; To examine if LASSI findings are consistent with previous research. Medical school students completed the LASSI and SDLRS before their first and second years (n = 168). Correlational and regression analyses were used to determine the predictive value of the LASSI and the SDLRS. Paired t-tests were used to test if the two measurement points differed. Bivariate correlations and R 2 s were compared with five other relevant studies. The SDLRS was moderately correlated with all LASSI subscales in both measures (r (152) =.255, p=.001) to (r (152) =.592, p =.000). The first SDLRS, nor the first LASSI, were predictive of academic performance. The second LASSI measure was a significant predictor of academic performance (R 2 (138) = 0.188, p = .003). Six prior LASSI studies yielded a range of R 2 s from 10-49%. The SDLRS is moderately correlated with all LASSI subscales. However, the predictive value of the SDLRS and LASSI differ. The SDLRS does not appear to be directly related to academic performance, but LASSI subscales: Concentration, Motivation, Time Management, and Test Strategies tend to be correlated. The explained LASSI variance ranges from 10% to 49%, indicating a small to substantial effect. Utilizing the LASSI to provide medical school students with information about their strengths and weaknesses and implementing targeted support in specific study strategies may yield positive academic performance outcomes.
Aksnes, D W; Kimtys, L
2004-01-01
The pore size distributions of four controlled pore glasses and three silica gels with nominal diameters in the range 4-24 nm were determined by measuring the 1H and 2H NMR signals from the non-frozen fraction of confined benzene and perdeuterated benzene as a function of temperature, in steps of ca. 0.1-1 K. The liquid and solid components of the adsorbate were distinguished, on the basis of the spin-spin relaxation time T2, by employing a spin-echo sequence. The experimental intensity curves of the liquid component are well represented by a sum of two error functions. The mean melting point depression of benzene and perdeuterated benzene confined in the four controlled pore glasses, with pore radius R, follows the simplified Gibbs-Thompson equation DeltaT=kp/R with a kp value of 44 K nm. As expected, the kp value mainly determines the position of the pore size distribution curve, i.e., the mean pore radius, while the transition width determines the shape of the pore size distribution curve. The excellent agreement between the results from the 1H and 2H measurements shows that the effect of the background absorption from protons in physisorbed water and silanol groups is negligible under the experimental conditions used. The overall pore size distributions determined by NMR are in reasonable agreement with the results specified by the manufacturer, or measured by us using the N2 sorption technique. The NMR method, which is complementary to the conventional gas sorption method, is particularly appropriate for studying pore sizes in the mesoporous range.
Extraction and LC determination of lysine clonixinate salt in water/oil microemulsions.
Pineros, I; Ballesteros, P; Lastres, J L
2002-02-01
A new reversed-phase high performance liquid chromatography method has been developed and validated for the quantitative determination of lysine clonixinate salt in water/oil microemulsions. The mobile phase was acetonitrile-buffer phosphate pH 3.3. Detection was UV absorbance at 252 nm. The precision and accurately of the method were excellent. The established linearity range was 5-60 microg ml(-1) (r(2)=0.999). Microemulsions samples were dispersed with chloroform and extracted lysine clonixinate salt with water. This easy method employing chloroformic extraction has been done three times. The recovery of lysine clonixinate salt from spiked placebo and microemulsion were >90% over the linear range.
Ma, Teng; Li, Zheng; Jia, Qiong; Zhou, Weihong
2016-07-01
We developed a CE and ultrasound-assisted temperature-controlled ionic liquid emulsification microextraction method for the determination of four parabens (methyl paraben, ethyl paraben, propyl paraben, and butyl paraben) in personal care products including mouthwash and toning lotion. In the proposed extraction procedure, ionic liquid (IL, 1-octyl-3-methylimidazolium hexafluorophosphate) was used as extraction solvent, moreover, no disperser solvent was needed. Parameters affecting the extraction efficiency including volume of IL, heating temperature, ultrasonic time, extraction time, sample pH, ionic strength, and centrifugation time were optimized. Under the optimized conditions, the method was found to be linear over the range of 3-500 ng/mL with coefficient of determination (R(2) ) in the range of 0.9990-0.9998. The LODs and LOQs for the four parabens were 0.45-0.72 ng/mL and 1.50-2.40 ng/mL, respectively. Intraday and interday precisions (RSDs, n = 5) were in the range of 5.4-6.8% and 7.0-8.7%, respectively. The recoveries of parabens at different spiked levels ranged from 71.9 to 119.2% with RSDs less than 9.5%. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Ming, Liang; Xi, Xia; Chen, Tingting; Liu, Jie
2008-01-01
We have developed a simple, convenient and inexpensive voltammetric method for determining trace Sudan I contamination in chili powder, based on the catalyzed electrochemical reduction of Sudan I at the carbon nanotube modified electrode. Under optimized conditions, the method exhibited acceptable analytical performance in terms of linearity (over the concentration range 6.0×10−7 to 7.5×10−5 M, r = 0.9967), detection limit (2.0×10−7 M) and reproducibility (RSD = 4.6%, n=10, for 2.0×10−5 M Sudan I). PMID:27879800
NASA Astrophysics Data System (ADS)
Casa, G.; Castrillo, A.; Galzerano, G.; Wehr, R.; Merlone, A.; di Serafino, D.; Laporta, P.; Gianfrani, L.
2008-05-01
We report on a new optical implementation of primary gas thermometry based on laser-absorption spectrometry in the near infrared. The method consists in retrieving the Doppler broadening from highly accurate observations of the line shape of the R(12) ν1+2ν20+ν3 transition in CO2 gas at thermodynamic equilibrium. Doppler width measurements as a function of gas temperature, ranging between the triple point of water and the gallium melting point, allowed for a spectroscopic determination of the Boltzmann constant with a relative accuracy of ˜1.6×10-4.
Six-minute walk test in children and adolescents with cystic fibrosis.
Cunha, Maristela Trevisan; Rozov, Tatiana; de Oliveira, Rosangela Caitano; Jardim, José R
2006-07-01
The 6-min walk test is a simple, rapid, and low-cost method that determines tolerance to exercise. We examined the reproducibility of the 6-min walk test in 16 children with cystic fibrosis (11 female, 5 male; age range, 11.0 +/- 1.9 years). We related the distance walked and the work performed (distance walked x body weight) with nutritional (body mass index and respiratory muscle strength) and clinical (degree of bronchial obstruction and Shwachman score) status. Patients were asked to walk as far as possible upon verbal command on two occasions. There was no statistical difference between distances walked (582.3 +/- 60 and 598.2 +/- 56.8 m, P = 0.31), heart rate, respiratory rate, pulse oxygen saturation, arterial blood pressure, dyspnea, and percentage of maximal heart rate for age in the two tests. Distance walked correlated (Pearson) with maximal expiratory pressure (98.6 +/- 28.1 cmH2O, r = 0.60, P < 0.01), maximal heart rate (157.9 +/- 10.1 bpm, r = 0.59, P < 0.02), Borg dyspnea scale (1.7 +/- 2.4, r = 0.55, P < 0.03), and double product (blood pressure x heart rate; r = 0.59, P < 0.02). The product of distance walked and body weight (work) correlated (Pearson) with height (r = 0.83, P = 0.000), maximal expiratory pressure (r = 0.64, P < 0.01), systolic blood pressure (r = 0.56, P < 0.02), and diastolic blood pressure (r = 0.55, P < 0.03). We conclude that the 6-min walk test is reproducible and easy to perform in children and adolescents with cystic fibrosis. The distance walked was related to the clinical variables studied. Work in the 6-min walk test may be an additional parameter in the determination of physical capacity.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Alfonso, M. C.; Bennett, M. E.; Folden, C. M.
2015-06-20
The extraction behavior of the Rf homologs, Zr and Hf, has been studied in HCl, HNO3, and H2SO4 media using TEVA (R) (a trioctyl and tridecyl methyl ammonium-based resin) and UTEVA (R) (a diamyl amylphosphonate-based resin). All six systems were considered for the future chemical characterization of Rf. Batch uptake studies were first performed to determine which systems could separate Zr and Hf and these results were used to determine what acid concentration range to focus on for the column studies. The batch uptake studies showed that UTEVA separates Zr and Hf in all media, while the intergroup separation wasmore » only observed in HCl media with TEVA. Both HCl systems showed viability for potential extraction chromatographic studies of Rf.« less
Torabi, Behzad; Shemirani, Farzaneh
2014-03-01
Unusual amounts of retinoic acid (RA) isomers play an important role in abnormal morphological development of mammals; such as rat embryos. Each isomer of RA has a unique function in first steps of embryonic life. In the current study, a new method for preconcentration and simultaneous determination of all-trans retinoic acid, 13-cis retinoic acid, 9-cis retinoic acid and 9,13-di-cis retinoic acid in rat whole rudimentary embryo culture (RWEC) has been developed. RA isomers were extracted from samples by conjugation to appropriate amount of surface modified CdSe quantum dots (QDs) prior to HPLC/UV determination. In order to quickly release of the analytes with unchanged form, separated RA-QD conjugation were irradiated by intensive near infrared wavelength (NIR). Low energy NIR irradiation results in maintaining the primary forms of RA isomers during the release. The conjugation and release mechanisms were described and experimental parameters were investigated in detail. Under optimized conditions, the method was linear in the range of 0.040-34.600 pmol g(-1) for all-trans RA (R(2)=0.9996), 0.070-34.200 pmol g(-1) for 13-cis RA (R(2)=0.9992), 0.050-35.300 pmol g(-1) for 9,13-di-cis RA (R(2)=0.9998) and 0.050-32.900 pmol g(-1) for 9-cis RA (R(2)=0.9990). The present method can be useful for retinoic acid monitoring in clinical studies. © 2013 Published by Elsevier B.V.
Study of GRBs Hosts Galaxies Vicinity Properties
NASA Astrophysics Data System (ADS)
Bernal, S.; Vasquez, N.; Hoyle, F.
2017-07-01
The study of GRBs host galaxies and its vicinity could provide constrains on the progenitor and an opportunity to use these violent explosions to characterize the nature of the highredshift universe. Studies of GRB host galaxies reveal a population of starforming galaxies with great diversity, spanning a wide range of masses, star formation rate, and redshifts. In order to study the galactic ambient of GRBs we used the S. Savaglio catalog from 2015 where 245 GRBs are listed with RA-Dec position and z. We choose 22 GRBs Hosts galaxies from Savaglio catalog and SDSS DR12, with z range 0
Armstrong, David S.; Parker, Gene W.; Richards, Todd A.
2003-01-01
Streamflow characteristics and methods for determining streamflow requirements for habitat protection were investigated at 23 active index streamflow-gaging stations in southern New England. Fish communities sampled near index streamflow-gaging stations in Massachusetts have a high percentage of fish that require flowing-water habitats for some or all of their life cycle. The relatively unaltered flow condition at these sites was assumed to be one factor that has contributed to this condition. Monthly flow durations and low flow statistics were determined for the index streamflow-gaging stations for a 25- year period from 1976 to 2000. Annual hydrographs were prepared for each index station from median streamflows at the 50-percent monthly flow duration, normalized by drainage area. A median monthly flow of 1 ft3/s/mi2 was used to split hydrographs into a high-flow period (November–May), and a low-flow period (June–October). The hydrographs were used to classify index stations into groups with similar median monthly flow durations. Index stations were divided into four regional groups, roughly paralleling the coast, to characterize streamflows for November to May; and into two groups, on the basis of base-flow index and percentage of sand and gravel in the contributing area, for June to October. For the June to October period, for index stations with a high base-flow index and contributing areas greater than 20 percent sand and gravel, median streamflows at the 50-percent monthly flow duration, normalized by drainage area, were 0.57, 0.49, and 0.46 ft3/s/mi2 for July, August, and September, respectively. For index stations with a low base-flow index and contributing areas less than 20 percent sand and gravel, median streamflows at the 50-percent monthly flow duration, normalized by drainage area, were 0.34, 0.28, and 0.27 ft3/s/mi2 for July, August, and September, respectively. Streamflow variability between wet and dry years can be characterized by use of the interquartile range of median streamflows at selected monthly flow durations. For example, the median Q50 discharge for August had an interquartile range of 0.30 to 0.87 ft3/s/mi2 for the high-flow group and 0.16 to 0.47 ft3/s/mi2 for the low-flow group. Streamflow requirements for habitat protection were determined for 23 index stations by use of three methods based on hydrologic records, the Range of Variability Approach, the Tennant method, and the New England Aquatic-Base-Flow method. Normalized flow management targets determined by the Range of Variability Approach for July, August, and September ranged between 0.21 and 0.84 ft3/s/mi2 for the low monthly flow duration group, and 0.37 and 1.27 ft3/s/mi2 for the high monthly flow duration group. Median streamflow requirements for habitat protection during summer for the 23 index streamflow-gaging stations determined by the Tennant method, normalized by drainage area, were 0.81, 0.61, and 0.21 ft3/s/mi2 for the Tennant 40-, 30-, and 10-percent of the mean annual flow methods, representing good, fair, and poor stream habitat conditions in summer, according to Tennant. New England Aquatic-Base-Flow streamflow requirements for habitat protection during summer were determined from median of monthly mean flows for August for index streamflow-gaging stations having drainage areas greater than 50 mi2 . For five index streamflow-gaging stations in the low median monthly flow group, the average median monthly mean streamflow for August, normalized by drainage area, was 0.48 ft3/s/mi2. Streamflow requirements for habitat protection were determined for riffle habitats near 10 index stations by use of two methods based on hydraulic ratings, the Wetted-Perimeter and R2Cross methods. Hydraulic parameters required by these methods were simulated by calibrated HEC-RAS models. Wetted-Perimeter streamflow requirements for habitat protection, normalized by drainage area, ranged between 0.13 and 0.58 ft3/s/mi2, and had a median value of 0.37 ft3/s/mi2. Streamflow requirements determined by the R2Cross 3-of-3 criteria method ranged between 0.39 and 2.1 ft3/s/mi2 , and had a median of 0.84 ft3/s/mi2. Streamflow requirements determined by the R2Cross 2-of-3 criteria method, normalized by drainage area, ranged between 0.16 and 0.85 ft3/s/mi2 and had a median of 0.36 ft3/s/mi2 , respectively. Streamflow requirements determined by the different methods were evaluated by comparison to streamflow statistics from the index streamflow-gaging stations.
Li, Jianbo; Sun, Weiyan; Wang, Xiaojiao; Duan, Huimin; Wang, Yanhui; Sun, Yuanling; Ding, Chaofan; Luo, Chuannan
2016-08-01
An electrochemical sensor of acetaminophen based on poly(diallyldimethylammonium chloride) (PDDA)-functionalized reduced graphene-loaded Al2O3-Au nanoparticles coated onto glassy carbon electrode (Al2O3-Au/PDDA/reduced graphene oxide (rGO)/glass carbon electrode (GCE)) were prepared by layer self-assembly technique. The as-prepared electrode-modified materials were characterized by scanning electron microscopy, X-ray powder diffraction, and Fourier transform infrared spectroscopy. The electrocatalytic performances of Al2O3-Au/PDDA/rGO-modified glassy carbon electrode toward the acetaminophen were investigated by cyclic voltammetry and differential pulse voltammetry. The modified electrodes of graphene oxide (GO)/GCE, PDDA/rGO/GCE, and Al2O3-Au/PDDA/rGO/GCE were constructed for comparison and learning the catalytic mechanism. The research showed Al2O3-Au/PDDA/rGO/GCE having good electrochemical performance, attributing to the synergetic effect that comes from the special nanocomposite structure and physicochemical properties of Al2O3-Au nanoparticles and graphene. A low detection limit of 6 nM (S/N = 3) and a wide linear detection range from 0.02 to 200 μM (R (2) = 0.9970) was obtained. The preparation of sensor was successfully applied for the detection of acetaminophen in commercial pharmaceutical pills. Graphical abstract Schematic diagram of synthesis of Al2O3-Au/PDDA/rGO/GCE.
A facile low-cost enzymatic paper-based assay for the determination of urine creatinine.
Talalak, Kwanrutai; Noiphung, Julaluk; Songjaroen, Temsiri; Chailapakul, Orawon; Laiwattanapaisal, Wanida
2015-11-01
Creatinine is one of many markers used to investigate kidney function. This paper describes a low-cost enzymatic paper-based analytical device (enz-PAD) for determining urine creatinine. The disposable dead volumes of creatinine enzyme reagents from an automatic analyser cassette were utilised. Whatman No. 3 paper was cut into long rectangular shapes (4×40 mm(2)) on which the enzyme reagents, R1 and R2, were adsorbed in two consecutive regions. The assay was performed by immersing test strips into urine samples contained in microwells to allow creatinine in the sample to react with immobilised active ingredients and, then, traverse via capillary action to the detection area where chromogen products accumulated. The method is based on hydrogen peroxide (H2O2) formation via creatinine conversion using creatininase, creatinase, and sarcosine oxidase. The liberated H2O2 reacts with 4-aminophenazone and 2,4,6-triiodo-3-hydroxybenzoic acid to form quinoneimine with a pink-red colour at the detection zone. The linear range of the creatinine assay was 2.5-25 mg dL(-1) (r(2)=0.983), and the detection limit was 2.0 mg dL(-1). The colorimetric enz-PAD for the creatinine assay was highly correlated with a conventional alkaline picrate method when real urine samples were evaluated (r(2)=0.977; n=40). This simple and nearly zero-cost paper-based device provides a novel alternative method for screening urinary creatinine and will be highly beneficial for developing countries. Copyright © 2015 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Iorio, L.
2012-07-01
We put independent model dynamical constraints on the net electric charge Q of some astronomical and astrophysical objects by assuming that their exterior spacetimes are described by the Reissner-Nordström, metric, which induces an additional potential {U_RN ∝ Q^2 r^{-2}}. From the current bounds {Δ dot \\varpi} on any anomalies in the secular perihelion rate {dot \\varpi} of Mercury and the Earth-mercury ranging Δ ρ, we have {|Q_{⊙}| ≲ 1-0.4 × 10^{18} C}. Such constraints are 60-200 times tighter than those recently inferred in literature. For the Earth, the perigee precession of the Moon, determined with the Lunar Laser Ranging technique, and the intersatellite ranging Δ ρ for the GRACE mission yield {|Q_{⊕} | ≲ 5-0.4 × 10^{14} C}. The periastron rate of the double pulsar PSR J0737-3039A/B system allows to infer {|Q_NS | ≲ 5× 10^{19} C}. According to the perinigricon precession of the main sequence S2 star in Sgr A*, the electric charge carried by the compact object hosted in the Galactic Center may be as large as {|Q_{bullet} | ≲ 4× 10^{27} C}. Our results extend to other hypothetical power-law interactions inducing extra-potentials {U_pert = Ψ r^{-2}} as well. It turns out that the terrestrial GRACE mission yields the tightest constraint on the parameter {Ψ}, assumed as a universal constant, amounting to {|Ψ| ≲ 5× 109 {m^4 s^{-2}}}.
Vocal tract resonances in singing: The soprano voice
NASA Astrophysics Data System (ADS)
Joliveau, Elodie; Smith, John; Wolfe, Joe
2004-10-01
The vocal tract resonances of trained soprano singers were measured while they sang a range of vowels softly at different pitches. The measurements were made by broad band acoustic excitation at the mouth, which allowed the resonances of the tract to be measured simultaneously with and independently from the harmonics of the voice. At low pitch, when the lowest resonance frequency R1 exceeded f0, the values of the first two resonances R1 and R2 varied little with frequency and had values consistent with normal speech. At higher pitches, however, when f0 exceeded the value of R1 observed at low pitch, R1 increased with f0 so that R1 was approximately equal to f0. R2 also increased over this high pitch range, probably as an incidental consequence of the tuning of R1. R3 increased slightly but systematically, across the whole pitch range measured. There was no evidence that any resonances are tuned close to harmonics of the pitch frequency except for R1 at high pitch. The variations in R1 and R2 at high pitch mean that vowels move, converge, and overlap their positions on the vocal plane (R2,R1) to an extent that implies loss of intelligibility. .
SU-E-T-98: An Analysis of TG-51 Electron Beam Calibration Correction Factor Uncertainty
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, P; Alvarez, P; Taylor, P
Purpose: To analyze the uncertainty of the TG-51 electron beam calibration correction factors for farmer type ion chambers currently used by institutions visited by IROC Houston. Methods: TG-51 calibration data were collected from 181 institutions visited by IROC Houston physicists for 1174 and 197 distinct electron beams from modern Varian and Elekta accelerators, respectively. Data collected and analyzed included ion chamber make and model, nominal energy, N{sub D,w}, I{sub 50}, R{sub 50}, k’R{sub 50}, d{sub ref}, P{sub gr} and pdd(d{sub ref}). k’R{sub 50} data for parallel plate chambers were excluded from the analysis. Results: Unlike photon beams, electron nominal energymore » is a poor indicator of the actual energy as evidenced by the range of R{sub 50} values for each electron beam energy (6–22MeV). The large range in R{sub 50} values resulted k’R{sub 50} values with a small standard deviation but large range between maximum value used and minimum value (0.001–0.029) used for a specific Varian nominal energy. Varian data showed more variability in k’R{sub 50} values than the Elekta data (0.001–0.014). Using the observed range of R{sub 50} values, the maximum spread in k’R{sub 50} values was determined by IROC Houston and compared to the spread of k’R{sub 50} values used in the community. For Elekta linacs the spreads were equivalent, but for Varian energies of 6 to 16MeV, the community spread was 2 to 6 times larger. Community P{sub gr} values had a much larger range of values for 6 and 9 MeV values than predicted. The range in Varian pdd(d{sub ref} ) used by the community for low energies was large, (1.4–4.9 percent), when it should have been very close to unity. Exradin, PTW Roos and PTW farmer chambers N{sub D,w} values showed the largest spread, ≥11 percent. Conclusion: While the vast majority of electron beam calibration correction factors used are accurate, there is a surprising spread in some of the values used.« less
Galaxy Number Counts from the Sloan Digital Sky Survey Commissioning Data
NASA Astrophysics Data System (ADS)
Yasuda, Naoki; Fukugita, Masataka; Narayanan, Vijay K.; Lupton, Robert H.; Strateva, Iskra; Strauss, Michael A.; Ivezić, Željko; Kim, Rita S. J.; Hogg, David W.; Weinberg, David H.; Shimasaku, Kazuhiro; Loveday, Jon; Annis, James; Bahcall, Neta A.; Blanton, Michael; Brinkmann, Jon; Brunner, Robert J.; Connolly, Andrew J.; Csabai, István; Doi, Mamoru; Hamabe, Masaru; Ichikawa, Shin-Ichi; Ichikawa, Takashi; Johnston, David E.; Knapp, G. R.; Kunszt, Peter Z.; Lamb, D. Q.; McKay, Timothy A.; Munn, Jeffrey A.; Nichol, Robert C.; Okamura, Sadanori; Schneider, Donald P.; Szokoly, Gyula P.; Vogeley, Michael S.; Watanabe, Masaru; York, Donald G.
2001-09-01
We present bright galaxy number counts in five broad bands (u', g', r', i', z') from imaging data taken during the commissioning phase of the Sloan Digital Sky Survey (SDSS). The counts are derived from two independent stripes of imaging scans along the celestial equator, one each toward the northern and the southern Galactic cap, covering about 230 and 210 deg2, respectively. A careful study is made to verify the reliability of the photometric catalog. For galaxies brighter than r*=16, the catalog produced by automated software is examined against eye inspection of all objects. Statistically meaningful results on the galaxy counts are obtained in the magnitude range 12<=r*<=21, using a sample of 900,000 galaxies. The counts from the two stripes differ by about 30% at magnitudes brighter than r*=15.5, consistent with a local 2 σ fluctuation due to large-scale structure in the galaxy distribution. The shape of the number counts-magnitude relation brighter than r*=16 is well characterized by N~100.6m, the relation expected for a homogeneous galaxy distribution in a ``Euclidean'' universe. In the magnitude range 16
Determination of tiropramide in human plasma by liquid chromatography-tandem mass spectrometry.
Lee, Hye Won; Ji, Hye Young; Kim, Hee Hyun; Cho, Hea-Young; Lee, Yong-Bok; Lee, Hye Suk
2003-11-05
A rapid, sensitive and selective liquid chromatography-tandem mass spectrometric (LC/MS/MS) method for the determination of tiropramide in human plasma was developed. Tiropramide and internal standard, cisapride were extracted from human plasma by liquid-liquid extraction and analyzed on a Luna C8 column with the mobile phase of acetonitrile-ammonium formate (10mM, pH 4.5) (50:50, v/v). The analytes was detected using an electrospray ionization tandem mass spectrometry in the multiple-reaction-monitoring mode. The standard curve was linear (r=0.998) over the concentration range of 2.0-200 ng/ml. The intra- and inter-assay coefficients of variation ranged from 2.8 to 7.8 and 6.7 to 8.9%, respectively. The recoveries of tiropramide ranged from 50.2 to 53.1%, with that of cisapride (internal standard) being 60.9+/-5.3%. The lower limit of quantification for tiropramide was 2.0 ng/ml using 100 microl plasma sample. This method was applied to the pharmacokinetic study of tiropramide in human.
Kandpal, Lalit Mohan; Lee, Hoonsoo; Kim, Moon S.; Mo, Changyeun; Cho, Byoung-Kwan
2013-01-01
Spectroscopy has proven to be an efficient tool for measuring the properties of meat. In this article, hyperspectral imaging (HSI) techniques are used to determine the moisture content in cooked chicken breast over the VIS/NIR (400–1,000 nm) spectral range. Moisture measurements were performed using an oven drying method. A partial least squares regression (PLSR) model was developed to extract a relationship between the HSI spectra and the moisture content. In the full wavelength range, the PLSR model possessed a maximum R2p of 0.90 and an SEP of 0.74%. For the NIR range, the PLSR model yielded an R2p of 0.94 and an SEP of 0.71%. The majority of the absorption peaks occurred around 760 and 970 nm, representing the water content in the samples. Finally, PLSR images were constructed to visualize the dehydration and water distribution within different sample regions. The high correlation coefficient and low prediction error from the PLSR analysis validates that HSI is an effective tool for visualizing the chemical properties of meat. PMID:24084119
NASA Astrophysics Data System (ADS)
Liu, Wei; Ma, Jinju; Yao, Xinding; Fang, Ruina; Cheng, Liang
2018-05-01
The solubilities of R-(+)-2-(4-hydroxyphenoxy)propanoic acid (D-HPPA) in methanol, ethanol and various methanol-ethanol mixtures are determined in the temperature range from 273.15 to 323.15 K at atmospheric pressure using a laser detecting system. The solubilities of D-HPPA increase with increasing mole fraction of ethanol in the methanol-ethanol mixtures. Experimental data were correlated with Buchowski-Ksiazczak λ h equation and modified Apelblat equation; the first one gives better approximation for the experimental results. The enthalpy, entropy and Gibbs free energy of D-HPPA dissolution in methanol, ethanol and methanol-ethanol mixtures were also calculated from the solubility data.
Dacres, Helen; Michie, Michelle; Wang, Jian; Pfleger, Kevin D G; Trowell, Stephen C
2012-08-31
Bioluminescence resonance energy transfer (BRET) is an important tool for monitoring macromolecular interactions and is useful as a transduction technique for biosensor development. Förster distance (R(0)), the intermolecular separation characterized by 50% of the maximum possible energy transfer, is a critical BRET parameter. R(0) provides a means of linking measured changes in BRET ratio to a physical dimension scale and allows estimation of the range of distances that can be measured by any donor-acceptor pair. The sensitivity of BRET assays has recently been improved by introduction of new BRET components, RLuc2, RLuc8 and Venus with improved quantum yields, stability and brightness. We determined R(0) for BRET(1) systems incorporating novel RLuc variants RLuc2 or RLuc8, in combination with Venus, as 5.68 or 5.55 nm respectively. These values were approximately 25% higher than the R(0) of the original BRET(1) system. R(0) for BRET(2) systems combining green fluorescent proteins (GFP(2)) with RLuc2 or RLuc8 variants was 7.67 or 8.15 nm, i.e. only 2-9% greater than the original BRET(2) system despite being ~30-fold brighter. Crown Copyright © 2012. Published by Elsevier Inc. All rights reserved.
Different phenolic compounds activate distinct human bitter taste receptors.
Soares, Susana; Kohl, Susann; Thalmann, Sophie; Mateus, Nuno; Meyerhof, Wolfgang; De Freitas, Victor
2013-02-20
Bitterness is a major sensory attribute of several common foods and beverages rich in polyphenol compounds. These compounds are reported as very important for health as chemopreventive compounds, but they are also known to taste bitter. In this work, the activation of the human bitter taste receptors, TAS2Rs, by six polyphenol compounds was analyzed. The compounds chosen are present in a wide range of plant-derived foods and beverages, namely, red wine, beer, tea, and chocolate. Pentagalloylglucose (PGG) is a hydrolyzable tannin, (-)-epicatechin is a precursor of condensed tannins, procyanidin dimer B3 and trimer C2 belong to the condensed tannins, and malvidin-3-glucoside and cyanidin-3-glucoside are anthocyanins. The results show that the different compounds activate different combinations of the ~25 TAS2Rs. (-)-Epicatechin activated three receptors, TAS2R4, TAS2R5, and TAS2R39, whereas only two receptors, TAS2R5 and TAS2R39, responded to PGG. In contrast, malvidin-3-glucoside and procyanidin trimer stimulated only one receptor, TAS2R7 and TAS2R5, respectively. Notably, tannins are the first natural agonists found for TAS2R5 that display high potency only toward this receptor. The catechol and/or galloyl groups appear to be important structural determinants that mediate the interaction of these polyphenolic compounds with TAS2R5. Overall, the EC(50) values obtained for the different compounds vary 100-fold, with the lowest values for PGG and malvidin-3-glucoside compounds, suggesting that they could be significant polyphenols responsible for the bitterness of fruits, vegetables, and derived products even if they are present in very low concentrations.
Color of meconium and interleukin-6.
Silva-Bravo, Raquel; Mayoral-Andrade, Gabriel; Zenteno, Edgar; Hernandez, Pedro; Martínez-Cruz, Ruth; Mayoral, Laura Perez-Campos; Aguilar-Ruiz, Sergio; Paz-Pacheco, Alberto; Zarate-Aspiros, Romeo; López-Bravo, Magdalena; Roldan-Aragon, Yuri; Pérez-Campos, Eduardo
2012-01-01
To test the hypothesis that the color of meconial fluid is associated with inflammatory biomarkers, by determining C-reactive protein (CRP) and Interleukin-6 (IL-6) in serum from the umbilical cord. In this prospective study, the authors selected 30 newborns with meconium-stained amniotic fluid (MSAF): 14 with green/brown 656 R color and 16 with brown/cinnamon 654 R color, and 20 newborns which showed clear amniotic fluid without MSAF (non-MSAF); all newborns were from mothers without risk factors for neonatal sepsis. IL-6 concentration from umbilical cord blood, [median of 12.9 pg/mL (interquartile range {IQR} 8.7-31.0)] of MSAF-green/brown 656 R increased significantly (p < 0.05) when compared with IL-6 concentration, [median of 9.2 pg/mL (IQR 7.2-12.2)] of newborns with clear amniotic fluid and without meconium. CRP from MSAF-green/brown 656 R was median of 0.5 mg/mL (IQR 0.0-2.7), and median of 1.0 mg/mL (IQR 0.0-5.5) from clear amniotic fluid, without meconium. Significant association was found between MSAF-green/brown 656 R and increase in IL-6, with normal CRP values.
Dhole, Seema M; Khedekar, Pramod B; Amnerkar, Nikhil D
2012-07-01
Repaglinide is a miglitinide class of antidiabetic drug used for the treatment of type 2 diabetes mellitus. A fast and reliable method for the determination of repaglinide was highly desirable to support formulation screening and quality control. UV spectrophotometric and reversed-phase high performance liquid chromatography (RP-HPLC) methods were developed for determination of repaglinide in the tablet dosage form. The UV spectrum recorded between 200 400 nm using methanol as solvent and the wavelength 241 nm was selected for the determination of repaglinide. RP-HPLC analysis was carried out using Agilent TC-C18 (2) column and mobile phase composed of methanol and water (80:20 v/v, pH adjusted to 3.5 with orthophosphoric acid) at a flow rate of 1.0 ml/min. Parameters such as linearity, precision, accuracy, recovery, specificity and ruggedness are studied as reported in the International Conference on Harmonization (ICH) guidelines. The developed methods illustrated excellent linearity (r(2) > 0.999) in the concentration range of 5-30 μg/ml and 5-50 μg/ml for UV spectrophotometric and HPLC methods, respectively. Precision (%R.S.D < 1.50) and mean recoveries were found in the range of 99.63-100.45% for UV spectrophotometric method and 99.71-100.25% for HPLC method which shows accuracy of the methods. The developed methods were found to be reliable, simple, fast, accurate and successfully used for the quality control of repaglinide as a bulk drug and in pharmaceutical formulations.
Dhole, Seema M.; Khedekar, Pramod B.; Amnerkar, Nikhil D.
2012-01-01
Background: Repaglinide is a miglitinide class of antidiabetic drug used for the treatment of type 2 diabetes mellitus. A fast and reliable method for the determination of repaglinide was highly desirable to support formulation screening and quality control. Objective: UV spectrophotometric and reversed-phase high performance liquid chromatography (RP-HPLC) methods were developed for determination of repaglinide in the tablet dosage form. Materials and Methods: The UV spectrum recorded between 200 400 nm using methanol as solvent and the wavelength 241 nm was selected for the determination of repaglinide. RP-HPLC analysis was carried out using Agilent TC-C18 (2) column and mobile phase composed of methanol and water (80:20 v/v, pH adjusted to 3.5 with orthophosphoric acid) at a flow rate of 1.0 ml/min. Parameters such as linearity, precision, accuracy, recovery, specificity and ruggedness are studied as reported in the International Conference on Harmonization (ICH) guidelines. Results: The developed methods illustrated excellent linearity (r2 > 0.999) in the concentration range of 5-30 μg/ml and 5-50 μg/ml for UV spectrophotometric and HPLC methods, respectively. Precision (%R.S.D < 1.50) and mean recoveries were found in the range of 99.63-100.45% for UV spectrophotometric method and 99.71-100.25% for HPLC method which shows accuracy of the methods. Conclusion: The developed methods were found to be reliable, simple, fast, accurate and successfully used for the quality control of repaglinide as a bulk drug and in pharmaceutical formulations. PMID:23781481
Hao, Chen; Erzheng, Chen; Anwei, Mao; Zhicheng, Yu; Baiyong, Shen; Xiaxing, Deng; Weixia, Zhang; Chenghong, Peng; Hongwei, Li
2007-12-01
Mycophenolate mofetil (MMF) is indicated as immunosuppressive therapy in liver transplantation. The abbreviated models for the estimation of mycophenolic acid (MPA) area under the concentration-time curve (AUC) have been established by limited sampling strategies (LSSs) in adult liver transplant recipients. In the current study, the performance of the abbreviated models to predict MPA exposure was validated in an independent group of patients. A total of 30 MPA pharmacokinetic profiles from 30 liver transplant recipients receiving MMF in combination with tacrolimus were used to compare 8 models' performance with a full 10 time-point MPA-AUC. Linear regression analysis and Bland-Altman analysis were used to compare the estimated MPA-AUC0-12h from each model against the measured MPA-AUC0-12h. A wide range of agreement was shown when estimated MPA-AUC0-12h was compared with measured MPA-AUC0-12h, and the range of coefficient of determination (r2) was from 0.479 to 0.936. The model based on MPA pharmacokinetic parameters C1h, C2h, C6h, and C8h had the best ability to predict measured MPA-AUC0-12h, with the best coefficient of determination (r2=0.936), the excellent prediction bias (2.18%), the best prediction precision (5.11%), and the best prediction variation (2SD=+/-7.88 mg.h/L). However, the model based on MPA pharmacokinetic sampling time points C1h, C2h, and C4h was more suitable when concerned with clinical convenience, which had shorter sampling interval, an excellent coefficient of determination (r2=0.795), an excellent prediction bias (3.48%), an acceptable prediction precision (14.37%), and a good prediction variation (2SD=+/-13.23 mg.h/L). Measured MPA-AUC0-12h could be best predicted by using MPA pharmacokinetic parameters C1h, C2h, C6h, and C8h. The model based on MPA pharmacokinetic parameters C1h, C2h, and C4h was more feasible in clinical application. Copyright (c) 2007 AASLD.
Visual Range: Concepts, Instrumental Determination, and Aviation Applications
1977-03-01
OF CONTENTS 0NAiRO5NCm Page.. . . .. .... . ... ... .. CHAPTER 1 INTRODUCTION -ls-IB- TI- R/- va-u’ g C-DES- CHAPTER 2 DEFINITION OF TERMS 2-1 2.1...Landing Aids Experiment Station. 3-11 3.8 Locations of transmissometers and ceilometer proposed by Mr. G . H. Stocker of the Landing Aids Experiment Station...his associates, espeofally J. F. Davis and J. C. Wilkerson; to D. H1. Hutchison and G . H. Stocker, Meteorologists at the Landing Aids Experiment Station
NASA Astrophysics Data System (ADS)
Rustamov, Ia.; Tavshunskii, G. A.; Khabibullaev, P. K.; Bessonova, T. S.; Sobolev, B. P.
1985-06-01
Experimental results are reported concerning the radiation coloring of nonstoichiometric crystals of the M(1-x)R(x)F(2+x) type in the presence of fluorite defects. Samples of the crystals are cut using the Stockbarger technique in a chemically active fluoridating atmosphere generated by pyrolysis of tetrafluoroethylene. The samples were irradiated at 77 and 300 K using a Co-60 gamma-ray source and the total doses were in the range 10 to the 6th to 10 to the 7th roentgen. Absorption spectra of the crystals were analogous spectra for MF2-RF3 single crystals with RF 3 contents of less than 1 mole percent. It is shown that the properties of radiation coloring of the two types of crystal are very different: F-centers formed at 300 K in Ca(1-x)R(x) F(2+x), but not at 77 K. Complex color centers were observed at 77 K in Ca(1-x)R(x)F(2+x) single crystals and the intensity of the centers was determined by the competition among the electron trapping processes involving the r3(+) ions. It is concluded that the coloring characteristics of the M(1-x)R(x)F(2+x) crystals are related to their structural characteristics as compared with the MF2-RF3 crystals.
Experimental Study of Heat Transfer to Small Cylinders in a Subsonic, High-temperature Gas Stream
NASA Technical Reports Server (NTRS)
Glawe, George E; Johnson, Robert C
1957-01-01
A Nusselt-Reynolds number relation for cylindrical thermocouple wires in crossflow was obtained from the experimental determination of time constants. Tests were conducted in exhaust gas over a temperature range of 2000 to 3400 R, a Mach number range of 0.3 to 0.8, and a static-pressure range from 2/3 to 1-1/3 atmospheres, yielding a Reynolds number range of 450 to 3000. The correlation obtained is Nu=(0.428 plus or minus 0.003) times the square root of Re* with average deviations of a single observation of 8.5 percent. This relation is the same as one previously reported for room-temperature conditions.
Cao, Tinghui; He, Min; Bai, Tianyu
2016-01-01
Objectives. To establish a new method for determination of antioxidant capacity of human urine based on the redox couple I2/KI and to evaluate the redox status of healthy and diseased individuals. Methods. The method was based on the linear relationship between oxidation reduction potential (ORP) and logarithm of concentration ratio of I2/KI. ORP of a solution with a known concentration ratio of I2/KI will change when reacted with urine. To determine the accuracy of the method, both vitamin C and urine were reacted separately with I2/KI solution. The new method was compared with the traditional method of iodine titration and then used to measure the antioxidant capacity of urine samples from 30 diabetic patients and 30 healthy subjects. Results. A linear relationship was found between logarithm of concentration ratio of I2/KI and ORP (R 2 = 0.998). Both vitamin C and urine concentration showed a linear relationship with ORP (R 2 = 0.994 and 0.986, resp.). The precision of the method was in the acceptable range and results of two methods had a linear correlation (R 2 = 0.987). Differences in ORP values between diabetic group and control group were statistically significant (P < 0.05). Conclusions. A new method for measuring the antioxidant capacity of clinical urine has been established. PMID:28115919
Experimentally Determined Relationship between Extinction and Liquid Water Content.
1981-04-01
throuoh 3c. Each type Yze - ly show, ,i linar ’ela . measure! ant’it Thi ’i -wpe t , s , ss om v , function cf toe ’,c ir ., ’ genera m h 3 mechanically ge...APR 01 0 BRUCE, C W BRUCE, Y P YEE UCLASSIIED ERADCO WASI-TfR-06 5 El EEE~hhETE-E ThE-- ADm2 / ASL-TR-0083 Reports Control Symbol OSD-1366...ATMOSPHERIC SCIENCES LABORATORY ~White Sands Misile Range, NM 88002 NOTICES isclaimers The findings in this r7_port ire not to be construed as an
Doğan, Serkan; Doğan, Gŭlşen; Ašić, Adna; Besić, Larisa; Klimenta, Biljana; Hukić, Mirsada; Turan, Yusuf; Primorac, Dragan; Marjanović, Damir
2016-04-01
Analysis of Y-chromosome haplogroup distribution is widely used when investigating geographical clustering of different populations, which is why it plays an important role in population genetics, human migration patterns and even in forensic investigations. Individual determination of these haplogroups is mostly based on the analysis of single nucleotide polymorphism (SNP) markers located in the non-recombining part of Y-chromosome (NRY). On the other hand, the number of forensic and anthropology studies investigating short tandem repeats on the Y-chromosome (Y-STRs) increases rapidly every year. During the last few years, these markers have been successfully used as haplogroup prediction methods, which is why they have been used in this study. Previously obtained Y-STR haplotypes (23 loci) from 100 unrelated Turkish males recently settled in Sarajevo were used for the determination of haplogroups via 'Whit Athey's Haplogroup Predictor' software. The Bayesian probability of 90 of the studied haplotypes is greater than 92.2% and ranges from 51.4% to 84.3% for the remaining 10 haplotypes. A distribution of 17 different haplogroups was found, with the Y- haplogroup J2a being most prevalent, having been found in 26% of all the samples, whereas R1b, G2a and R1a were less prevalent, covering a range of 10% to 15% of all the samples. Together, these four haplogroups account for 63% of all Y-chromosomes. Eleven haplogroups (E1b1b, G1, I1, I2a, I2b, J1, J2b, L, Q, R2, and T) range from 2% to 5%, while E1b1a and N are found in 1% of all samples. Obtained results indicate that a large majority of the Turkish paternal line belongs to West Asia, Europe Caucasus, Western Europe, Northeast Europe, Middle East, Russia, Anatolia, and Black Sea Y-chromosome lineages. As the distribution of Y-chromosome haplogroups is consistent with the previously published data for the Turkish population residing in Turkey, it was concluded that the analyzed population could also be recognized as a representative sample of the Turkish population residing in Turkey.
Koyama, Tetsuo; Marumoto, Kohei; Uchiyama, Yuki; Miyake, Hiroji; Domen, Kazuhisa
2015-04-01
This study aimed to evaluate the prognostic efficacy of magnetic resonance diffusion tensor fractional anisotropy (FA) for patients with hemiparesis due to intracerebral hemorrhage. Diffusion tensor FA brain images were acquired 14-21 days after putaminal and/or thalamic hemorrhage. The ratio of FA values within the cerebral peduncles of the affected and unaffected hemispheres (rFA) was calculated for each patient (n = 40) and assessed for correlation with Brunnstrom stage (BRS, 1-6), motor component of the functional independence measure (FIM-motor, 13-91), and the total length of stay (LOS) until discharge from rehabilitation (P < .05). Ordinal logistic regression analyses were conducted to determine the relationships between rFA and specific outcomes as measured by BRS range (poor, BRS 1 or 2; moderate, BRS 3 or 4; and good, BRS 5 or 6; P < .05). The rFA values were .571-1.043 (median, .856) and BRS scores were 1-6 (median, 4) for shoulder/elbow/forearm, 1-6 (median, 4) for hand, and 2-6 (median, 4) for lower extremities. FIM-motor scores were 58-86 (median, 78) and LOS ranged from 42 to 225 days (median, 175.5 days). Correlation coefficients were statistically significant between rFA and shoulder/elbow/forearm BRS (.696), hand BRS (.779), lower extremity BRS (.631), FIM-motor (.442), and LOS (-.598). Logistic model fit was moderate for shoulder/elbow/forearm BRS (R(2) = .221) and lower extremity BRS (R(2) = .277), but was much higher for hand BRS (R(2) = .441). Diffusion tensor FA values are predictive of clinical outcome from hemiparesis due to putaminal and/or thalamic hemorrhage, particularly hand function recovery. Copyright © 2015 National Stroke Association. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Wabaidur, Saikh Mohammad; Lee, Sang Hak; Alothman, Zeid Abdullah; Siddiqui, Masoom Raza; Alam, Seikh Mafiz
2013-06-01
The simultaneous determination of harman and norharman using second derivative synchronous fluorescence method has been developed based on their natural fluorescence. Due to their similar molecular structures, it is difficult to determine them simultaneously in the mixture using conventional fluorimetry. Overlapping of fluorescence spectra was resolved by using a constant second derivative synchronous fluorimetry. The derivative synchronous spectrum, maintaining a constant difference of Δλ = 150 nm between emission and excitation for both the compounds, has been selected for the analysis. The range of application is between 0.182 and 18.2 μg/mL (correlation coefficient, R = 0.9982) for harman and between 0.504 and 16.8 μg/mL (correlation coefficient, R = 0.9962) for norharman. The recovery ranges of 98.5-101.1% for harman and 97.5-99.1% for norharman from their synthetic mixture was reported. The detection limits are 0.016 μg/mL and 0.038 μg/mL for harman and norharman, respectively. Similarly, the quantitation limit of the two compounds was found to be 0.049 and 0.109 μg/mL, respectively. The method was applied to the simultaneous determination of both compounds in coffee samples with satisfactory results.
Wabaidur, Saikh Mohammad; Lee, Sang Hak; Alothman, Zeid Abdullah; Siddiqui, Masoom Raza; Alam, Seikh Mafiz
2013-06-01
The simultaneous determination of harman and norharman using second derivative synchronous fluorescence method has been developed based on their natural fluorescence. Due to their similar molecular structures, it is difficult to determine them simultaneously in the mixture using conventional fluorimetry. Overlapping of fluorescence spectra was resolved by using a constant second derivative synchronous fluorimetry. The derivative synchronous spectrum, maintaining a constant difference of Δλ=150 nm between emission and excitation for both the compounds, has been selected for the analysis. The range of application is between 0.182 and 18.2 μg/mL (correlation coefficient, R=0.9982) for harman and between 0.504 and 16.8 μg/mL (correlation coefficient, R=0.9962) for norharman. The recovery ranges of 98.5-101.1% for harman and 97.5-99.1% for norharman from their synthetic mixture was reported. The detection limits are 0.016 μg/mL and 0.038 μg/mL for harman and norharman, respectively. Similarly, the quantitation limit of the two compounds was found to be 0.049 and 0.109 μg/mL, respectively. The method was applied to the simultaneous determination of both compounds in coffee samples with satisfactory results. Copyright © 2013 Elsevier B.V. All rights reserved.
Use of a single ventilator to support 4 patients: laboratory evaluation of a limited concept.
Branson, Richard D; Blakeman, Thomas C; Robinson, Bryce Rh; Johannigman, Jay A
2012-03-01
A mass-casualty respiratory failure event where patients exceed available ventilators has spurred several proposed solutions. One proposal is use of a single ventilator to support 4 patients. A ventilator was modified to allow attachment of 4 circuits. Each circuit was connected to one chamber of 2 dual-chambered, test lungs. The ventilator was set at a tidal volume (V(T)) of 2.0 L, respiratory frequency of 10 breaths/min, and PEEP of 5 cm H(2)O. Tests were repeated with pressure targeted breaths at 15 cm H(2)O. Airway pressure, volume, and flow were measured at each chamber. The test lungs were set to simulate 4 patients using combinations of resistance (R) and compliance (C). These included equivalent C and R, constant R and variable C, constant C and variable R, and variable C and variable R. When R and C were equivalent the V(T) distributed to each chamber of the test lung was similar during both volume (range 428-442 mL) and pressure (range 528-544 mL) breaths. Changing C while R was constant resulted in large variations in delivered V(T) (volume range 257-621 mL, pressure range 320-762 mL). Changing R while C was constant resulted in a smaller variation in V(T) (volume range 418-460 mL, pressure range 502-554 mL) compared to only C changes. When R and C were both varied, the range of delivered V(T) in both volume (336-517 mL) and pressure (417-676 mL) breaths was greater, compared to only R changes. Using a single ventilator to support 4 patients is an attractive concept; however, the V(T) cannot be controlled for each subject and V(T) disparity is proportional to the variability in compliance. Along with other practical limitations, these findings cannot support the use of this concept for mass-casualty respiratory failure.
Rumex L. species induce apoptosis in 1301, EOL-1 and H-9 cell lines.
Wegiera, Magdalena; Smolarz, Helena D; Bogucka-Kocka, Anna
2012-01-01
The Rumex L. (dock) species for many centuries have been used in medical treatment, through their adstringent, spasmolitic or cholagogic action. In the present study, the in vitro screening of cytotoxic activities of ethanol extract from roots, leaves and fruits of six Rumex species: R. acetosa L., R. acetosella L., R. confertus Willd., R. crispus L., R. hydrolapathum Huds. and R. obtusifolius L. were performed. We found remarkable cytotoxic activities on leukemic 1301 and EOL-1 cell lines and T cell line at concentration dependent manners. Cytotoxic activity was determined in two ways: trypan blue test and annexin-V FITC and propidium iodide assay. Received IC50 values of investigated extracts on 1301, EOL-1 and H-9 cell lines ranged from 0.22, 0.17 and 0.04 to 2.56, 1.91 and 1.83 mg/mL, respectively. Analysis of morphological changes demonstrated that the extract exerted cell-death via apoptosis. The overall activities of Rumex species support the traditional use of the extract from the fruits of R. confertus, R. crispus, R. hydrolapathum and R. obtusifolius in the treatment of cancer.
Winter range arrival and departure of white-tailed deer in northeastern Minnesota
Nelson, M.E.
1995-01-01
I analyzed 364 spring and 239 fall migrations by 194 white-tailed deer (Odocoileus virginianus) from 1975 to 1993 in northeastern Minnesota to determine the proximate cause of arrivals on and departures from winter ranges. The first autumn temperatures below -7?C initiated fall migrations for 14% (95% confidence interval (CI) = 0-30) of female deer prior to snowfall in three autumns, but only 2% remained on winter ranges. During 14 autumns, the first temperatures below -7?C coincidental with snowfalls elicited migration in 45% (95% CI = 34-57) of females, and 91 % remained on winter ranges. Arrival dates failed to correlate with independent variables of temperature and snow depth, precluding predictive modeling of arrival on winter ranges. During 13 years, a mean of 80% of females permanently arrived on winter ranges by 31 December. Mean departure dates from winter ranges varied annually (19 March - 4 May) and between winter ranges (14 days) and according to snow depth (15-cm differences). Only 15 - 41 % of deer departed when snow depths were> 30 cm but 80% had done so by the time of lO-cm depths. Mean weekly snow depths in March (18-85 cm) and mean temperature in April (0.3 -8.1 ?c) explained most of the variation in mean departure dates from two winter ranges (Ely, R2 = 0.87, P < 0.0005, n = 19 springs; Isabella, R2 = 0.85, P = 0.0001, n = 12 springs). Mean differences between observed mean departure dates and mean departure dates predicted from equations ranged from 3 days (predictions within the study area) to 8 days (predictions for winter ranges 100-440 km distant).
Qian, Jing; Hua, Mengjuan; Wang, Chengquan; Wang, Kan; Liu, Qian; Hao, Nan; Wang, Kun
2016-11-23
New strategies for onsite determination of trace 2,4,6-trinitrotoluene (TNT) explosives have become a research hotspot for homeland security needs against terrorism and environmental concerns. Herein, we designed a ratiometric fluorescence nanohybrid comprising 3-mercaptopropionic acid-capped green-emitting CdTe quantum dots (gQDs) encapsulated into SiO 2 sphere and l-cysteine (Lcys)-capped red-emitting CdTe QDs (rQDs) conjugated onto SiO 2 surface. The surface Lcys can be used as not only the stabilizer of the rQDs but also the primary amine provider which can react with TNT to form Meisenheimer complexes. Without any additional surface modification procedure, the fluorescence of rQDs equipped with Lcys was selectively quenched by TNT because electrons of the rQDs transferred to TNT molecules due to the formation of Meisenheimer complexes. Meanwhile, the embedded gQDs always remained constant. Upon exposure to increasing amounts of TNT, the fluorescence of rQDs could be gradually quenched and consequently the logarithm of the dual emission intensity ratios exhibited a good linear negative correlation with TNT concentration over a range of 10 nM-8 μM with a low detection limit of 3.3 nM. One can perform onsite visual determination of TNT with high resolution because the ratiometric fluorescence nanosensing system exhibited obvious fluorescence color changes. This sensing strategy has been successfully applied in real samples and already integrated in a filter paper-based assay, which enables potential fields use application featuring easy handling and cost-effectiveness. Copyright © 2016 Elsevier B.V. All rights reserved.
Evaluation of Endotracheal Tube Scraping on Airway Resistance.
Scott, J Brady; Dubosky, Meagan N; Vines, David L; Sulaiman, Adewunmi S; Jendral, Kyle R; Singh, Gagan; Patel, Ankeet; Kaplan, Carl A; Gurka, David P; Balk, Robert A
2017-11-01
Spontaneous breathing trials (SBTs) are used to assess the readiness for discontinuation of mechanical ventilation. When airway resistance (R aw ) is elevated, the imposed work of breathing can lead to prolongation of mechanical ventilation. Biofilm and mucus build-up within the endotracheal tube (ETT) can increase R aw . Scraping the ETT can remove the biofilm build-up and decrease mechanical R aw . The primary aim of this study was to evaluate the impact of ETT scraping on R aw . The secondary aim was to determine whether decreasing R aw would impact subsequent SBT success. Intubated, mechanically ventilated subjects were enrolled if they failed an SBT and had an R aw of > 10 cm H 2 O/L/s. SBT failure was based on institutional guidelines, and R aw was calculated by subtracting the difference between the measured peak and plateau pressures using a square flow waveform with an inspiratory flow set at 60 L/min. The endOclear device was inserted into the ETT and withdrawn per manufacturer's guidelines. Scraping was repeated until the ETT was cleared. Change in R aw was compared pre- and post-ETT scraping using a paired t test. A Mann-Whitney U test evaluated the difference in percentage change in R aw between SBT groups. Twenty-nine subjects completed the study. The mean pre- and post-ETT scraping R aw values were 15.17 ± 3.83 and 12.05 ± 3.19 cm H 2 O/L/s, respectively ( P < .001). Subsequent SBT success was 48%; however, there was no difference in percentage change in R aw between subsequent passed SBT (18.61% [interquartile range 8.90-33.93%]) and failed SBT (23.88% [interquartile range 0.00-34.80%]), U = 78.5, z = -0.284, P = .78. No adverse events were noted with ETT scraping. This study demonstrated that ETT scraping can reduce R aw . The decrease in R aw post-ETT scraping did not affect subsequent SBT success. Copyright © 2017 by Daedalus Enterprises.
NASA Astrophysics Data System (ADS)
Browne, E. J.; Herrero-Bervera, E.; Singer, B.
2005-12-01
New paleomagnetic measurements (directions and paleointensity determinations), coupled with precise 40Ar/39Ar radioisotopic dating, are revolutionizing our understanding of the geodynamo by providing detailed terrestrial lava records of the short-term behavior of the paleomagnetic field. As part of an investigation of the evolution of Koolau Volcano (one of the volcanoes comprising Oahu Island) and the short-term behavior of the geomagnetic field, we have sampled a long volcanic section located on the buttressed flank of the volcano within Halawa Valley. Prior paleomagnetic and K-Ar investigations of the Koolau (Volcano) Series revealed excursional directions (Site F of Doell and Dalrymple, 1973). The alkaline composition of lava flows, easy access, and close geographical proximity to K-Ar dated lava flows made this newly studied 120 m thick sequence of flows in Halawa valley an excellent candidate for detailed paleomagnetic analysis. At least eight samples collected from each of 28 successive flow-sites were stepwise demagnetized by both alternating field (5mT to 100mT) and thermal (from 28o C to 575-650oC) methods, and the mean directions obtained by principal component analysis. All samples yielded a strong and stable ChRM trending towards the origin based on no less than seven to nine steps, with thermal and AF results agreeing to a very high degree. Low field susceptibility versus temperature (k-T) analyses were conducted for individual lava flows, and the majority of them show reversible curves. Curie point determinations revealed a temperature close to or equal to 580oC, indicative of almost pure magnetite for most of the flows. Magnetic grain sizes analysis indicated SD-PSD sizes. The mean directions of magnetization of the entire section sampled indicate that about 10 m of the section are characterized by excursional directions (5 lava flows). In addition to the directional analyses we performed absolute paleointensity determinations on the 28 lavas sampled. We used the modified Thellier-Coe double heating method to determine paleointensities. pTRM checks were performed systematically one temperature step down the last pTRM acquisition in order to document magnetomineralogical changes during heating. The temperature was incremented by steps of 50o C between room temperature and 500oC and every 25-30o C. The paleointensity determinations were obtained from the slope of the Arai diagrams. Special care was taken to interpret the Arai diagrams within the same range of temperatures lower than 300oC unless a clear and unique slope would be present. Our paleointensity results indicate a near-zero reduced strength of the field during the excursional period ranging from 5 to 9 micro-Tesla. The corresponding VGPs are located off the southeast part of Africa, close to Madagascar. Initial 40Ar/39Ar incremental heating experiments on groundmass from nine flow-sites located at different stratigraphic levels yielded isochron ages ranging from 2.64+/-0.25 to 2.40+/-0.46 Ma indicating that the excursion may correlate with the C2r.2r-l Cryptochron of Cande and Kent [1995]. this is potentially the first terrestrial record of the ca. 2.4 Ma Cryptochron, a finding that will place important constraints on evolution of the entire Koolau shield edifice also.
Deelen, S M; Ollivett, T L; Haines, D M; Leslie, K E
2014-01-01
The objective of this study was to evaluate the utility of a digital Brix refractometer for the assessment of success of passive transfer of maternal immunoglobulin compared with the measurement of serum total protein (STP) by refractometry. Blood samples (n = 400) were collected from calves at 3 to 6d of age. Serum IgG concentration was determined by radial immunodiffusion (RID), and STP and percentage Brix (%Brix) were determined using a digital refractometer. The mean IgG concentration was 24.1g/L [standard deviation (SD) ± 10.0] with a range from 2.1 to 59.1g/L. The mean STP concentration was 6.0 g/dL (SD ± 0.8) with a range from 4.4 to 8.8 g/dL. The mean %Brix concentration was 9.2% (SD ± 0.9) with a range of 7.3 to 12.4%. Brix percentage was highly correlated with IgG (r = 0.93). Test characteristics were calculated to assess failure of passive transfer (FPT; serum IgG <10 g/L). The sensitivity and specificity of STP at 5.5 g/dL were 76.3 and 94.4%, respectively. A receiver operating characteristic curve was created to plot the true positive rate against the false positive rate for consecutive %Brix values. The optimal combination of sensitivity (88.9%) and specificity (88.9%) was at 8.4% Brix. Serum total protein was also positively correlated with %Brix (r = 1.00) and IgG (r = 0.93). Dairy producers can successfully monitor their colostrum management and the overall success of passive transfer using a digital Brix refractometer to estimate IgG concentration of colostrum and calf serum. Copyright © 2014 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
What does the shape of our back tell us? Correlation between sacrum orientation and lumbar lordosis.
Schmidt, Hendrik; Bashkuev, Maxim; Weerts, Jeronimo; Altenscheidt, Joern; Maier, Christoph; Reitmaier, Sandra
2018-04-01
Sacral slope and lumbar lordosis (LL) have been studied extensively in recent years via X-ray examinations and strongly correlate with each other. This raises, first, the question of the reproducibility of this correlation in multiple standing phases and, second, if this correlation can be achieved using non-radiological measurement tools. This study aimed (1) to determine the extent to which the back-shape measurements correspond to the correlations between the sacral slope and LL found in previous radiological investigations, (2) to identify a possible effect of age and gender on this correlation, and (3) to evaluate the extent to which this correlation is affected by repeated standing phases. This is an observational cohort study. A total of 410 asymptomatic subjects (non-athletes), 21 asymptomatic soccer players (athletes), and 176 patients with low back pain (LBP) were included. The correlation between sacrum orientation (SO) and LL was determined in six repetitive upright standing postures. A non-invasive strain-gauge based measuring system was used. Back-shape measurements yielded a similar correlation to that measured in previous X-ray examinations. The coefficient of determination (R 2 ) between SO and LL ranged between 0.76 and 0.79 for the asymptomatic cohort. Athletes showed the strongest correlation (0.76≤R 2 ≤0.84). For patients with LBP, the correlation substantially decreased (0.18≤R 2 ≤0.39). R 2 was not strongly affected by repeated standing phases. The correlation between SO and LL can be assessed by surface measurements of the back shape and is not influenced by natural variations in the standing posture. Copyright © 2017 Elsevier Inc. All rights reserved.
Chen, Antonia F; Bi, Wenzhu; Singhabahu, Dilrukshika; Londino, Joanne; Hohl, Justin; Ward, Maeve; Ward, W Timothy
2013-03-01
Prospective questionnaire administration study. To assess the ability to translate total and domain scores from Scoliosis Research Society (SRS)-24 to SRS-22r in a surgical-range, medical/interventional adolescent idiopathic scoliosis (AIS) patient population. Conversion of SRS-24 to SRS-22r is demonstrated in an operative cohort of patients with AIS, but not in a medical/interventional patient population. We simultaneously administered SRS-24 and SRS-22r questionnaires to 75 surgical-range, medical/interventional AIS patients and compared them. We performed analysis by regression modeling to produce conversion equations from SRS-24 to SRS-22r. The total SRS-24 score for these medical/interventional AIS patients was 92.5 ± 9.45 (mean, 3.9 ± 0.39), and the total SRS-22r score was 93.5 ± 9.63 (mean, 4.3 ± 0.44). The correlation between these 2 groups was fair (R 2 = 0.77) and improved to good when mental health or recall questions were removed. The correlation was also fair for total pain domains (R 2 = 0.73). However, there was poor correlation for general self-image (R 2 = 0.6) and unacceptable for post-treatment self-image (R 2 = 0.01), general function (R 2 = 0.52), activity function (R 2 = 0.56), and satisfaction (R 2 = 0.53). Compared with a published population of operative AIS patients, R 2 values for total SRS-24 scores, pain, general self-image, activity function, and satisfaction were similar (p > .05). The R 2 values for general function and combined general and activity function were significantly different between the operative and medical/interventional cohorts. Scoliosis Research Society-24 can be converted to SRS-22r scores with fair accuracy in the surgical-range, medical/interventional AIS patient population for total score, and total pain domains. The SRS-24 translates unacceptably to the SRS-22r in self-image, function, and satisfaction domains. The SRS-24 to SRS-22r conversion equations are similar to operative AIS patients, except for the function domain. Caution should be used when interpreting results based on translation of SRS-24 to SRS-22r values. Copyright © 2013 Scoliosis Research Society. Published by Elsevier Inc. All rights reserved.
Pierpoint, A C; Hapeman, C J; Torrents, A
2001-08-01
The relative rate constants for the reaction of ozone were determined for several substituted anilines in aqueous solutions at pH 6.5 and 1.5. At pH 6.5, with the exception of m- and p-nitroaniline, the rate constants obey Hammett's equation: log(k(X)/k(H)) = rho sigma. The departure of m- and p-nitroaniline may be explained by direct conjugation of the reaction center. The commonly used sigma(p)(-) value of 1.27, which extends the range of applicability of the Hammett equation, was insufficient to account for the conjugation effects on ozonation of p-nitroaniline; rho = -1.48 (R = 0.973). Use of amine group atomic charge determinations significantly improved correlations: (k(X)/k(H)) = 48.7 delta - 18.2 (R = 0.996). A linear plot of Hammett constants versus relative rate data at pH 1.5 showed poor correlation: rho = 0.72 (R = 0.572). Poor correlation was similarly observed for amine group atomic charge determinations, suggesting varied reaction mechanisms.
de Paula, Nattany T G; Barbosa, Elaine M O; da Silva, Paulo A B; de Souza, Gustavo C S; Nascimento, Valberes B; Lavorante, André F
2016-07-15
This work reports an in-line electrochemical reagent generation coupled to a flow injection biamperometric procedure for the determination of SO3(2-). The method was based on a redox reaction between the I3(-) and SO3(2-) ions, after the diffusion of SO2 through a gas diffusion chamber. Under optimum experimental conditions, a linear response ranging from 1.0 to 12.0 mg L(-1) (R=0.9999 and n=7), a detection and quantification limit estimated at 0.26 and 0.86 mg L(-1), respectively, a standard deviation relative of 0.4% (n=10) for a reference solution of 4.0 mg L(-1) SO3(2-) and sampling throughput for 40 determinations per hour were achieved. Addition and recovery tests with juice and wine samples were performed resulting in a range between 92% and 110%. There were no significant differences at a 95% confidence level in the analysis of eight samples when comparing the new method with a reference procedure. Copyright © 2016 Elsevier Ltd. All rights reserved.
Jeong, Birang; Roh, Jong Seong; Yoon, Michung; Yoon, Yoosik; Shin, Soon Shik; Cho, Hyun Joo; Kwon, Yong Soo; Yang, Heejung
2018-01-01
DF formula is a herbal preparation comprised three medicinal herbs, namely, Ephedra intermedia , Rheum palmatum , and Lithospermum erythrorhizon , which is being used for the treatment of obesity and liver fibrosis in Korean local clinics. Since the abovementioned three herbs exist with different proportions in DF formula and their chemical markers have different physiochemical properties; it is quite challenging to develop an analytical methodology for the determination of these chemical markers. For the analysis of the three herbs, five chemicals, (+)-pseudoephedrine (1) and (-)-ephedrine (2) for E. intermedia , aloe-emodin (3), and chrysophanol (4) for R. palmatum , and shikonin (5) for L. erythrorhizon , were selected for method validation of DF formula, and the analytical conditions were optimized and validated using high-performance liquid chromatography coupled with an ultraviolet detector (HPLC-UV). The specificities for the five compounds 1-5 were determined by their UV absorption spectra (1-4: 215 nm and 5: 520 nm). Their calibration curves showed good linear regressions with high correlation coefficient values ( R 2 > 0.9997). The limits of detection of these five markers were in the range 0.4-2.1 ng/mL, with the exception of 5 (12.7 ng/mL). The intraday variability for all the chemical markers was less than a Relative standard deviation (RSD) of 3%, except for 5 (RSD = 12.6%). In the case of interday analysis, 1 (1.0%), 2 (3.1%), and 4 (3.7%) showed much lower variabilities (RSD < 5%) than 3 (7.6%) and 5 (8.2%). Moreover, the five chemical markers showed good recoveries with good accuracies in the range of 90%-110%. The developed HPLC-UV method for the determination of the five chemical markers of the components of DF formula was validated. DF formula, the herbal composition of Ephedra intermedia , Rheum palmatum and Lithospermum erythrorhizon Five chemical markers in DF formula were (+)-pseudoephedrine (1) and (-)-ephedrine (2) for E. intermedia , aloe-emodin (3) and chrysopanol (4) for R. palmatum , and shikonin (5) for L. erythrorhizon , with quite different physico-chemical propertiesFive chemical markers in DF formula were determined by HPLC-UV Abbreviations used: EP: (-)-ephedrine; PSEP: (+)-pseudoephedrine; HPLC: High-performance liquid chromatography; UV: Ultraviolet; LOD: Limit of detection; LOQ: Limit of quantification; RSD: Relative standard deviation.
The I=2 ππ S-wave Scattering Phase Shift from Lattice QCD
Beane, S. R.; Chang, E.; Detmold, W.; ...
2012-02-16
The π +π + s-wave scattering phase-shift is determined below the inelastic threshold using Lattice QCD. Calculations were performed at a pion mass of m π ≈ 390 MeV with an anisotropic n f = 2+1 clover fermion discretization in four lattice volumes, with spatial extent L ≈ 2.0, 2.5, 3.0 and 3.9 fm, and with a lattice spacing of b s ≈ 0.123 fm in the spatial direction and b t b s/3.5 in the time direction. The phase-shift is determined from the energy-eigenvalues of π +π + systems with both zero and non-zero total momentum in the latticemore » volume using Luscher's method. Our calculations are precise enough to allow for a determination of the threshold scattering parameters, the scattering length a, the effective range r, and the shape-parameter P, in this channel and to examine the prediction of two-flavor chiral perturbation theory: m π 2 a r = 3+O(m π 2/Λ χ 2). Chiral perturbation theory is used, with the Lattice QCD results as input, to predict the scattering phase-shift (and threshold parameters) at the physical pion mass. Our results are consistent with determinations from the Roy equations and with the existing experimental phase shift data.« less
NASA Astrophysics Data System (ADS)
Pandey, Manoj Kumar; Ramachandran, Ramesh
2010-03-01
The application of solid-state NMR methodology for bio-molecular structure determination requires the measurement of constraints in the form of 13C-13C and 13C-15N distances, torsion angles and, in some cases, correlation of the anisotropic interactions. Since the availability of structurally important constraints in the solid state is limited due to lack of sufficient spectral resolution, the accuracy of the measured constraints become vital in studies relating the three-dimensional structure of proteins to its biological functions. Consequently, the theoretical methods employed to quantify the experimental data become important. To accentuate this aspect, we re-examine analytical two-spin models currently employed in the estimation of 13C-13C distances based on the rotational resonance (R 2) phenomenon. Although the error bars for the estimated distances tend to be in the range 0.5-1.0 Å, R 2 experiments are routinely employed in a variety of systems ranging from simple peptides to more complex amyloidogenic proteins. In this article we address this aspect by highlighting the systematic errors introduced by analytical models employing phenomenological damping terms to describe multi-spin effects. Specifically, the spin dynamics in R 2 experiments is described using Floquet theory employing two different operator formalisms. The systematic errors introduced by the phenomenological damping terms and their limitations are elucidated in two analytical models and analysed by comparing the results with rigorous numerical simulations.
[Accessibility of health services for users].
Sousa-Fragoso, M A; Villarreal-Ríos, E
2000-01-01
To measure the accessibility to health services and determine a model to explain this accessibility. All states of the Mexican Republic were included. The measurement of accessibility considers the availability of resources and the perception of barriers. Place of residence, education, participation in the work forces and household conditions were included in the model. The average of availability resources was 64.59% sd 15.68 (range 42 to 100) and the average corresponding to perception of barriers, 87.61% SD 4.04 (range 79.23 to 95.65). Accessibility was 71.50% SD 10.74 (range 56 to 96). The states with highest accessibility were the Federal District and Baja California Sur and the lowest, Chiapas and Oaxaca. The model included education and labor participation (R2 = 0.67, p < 0.05). Accessibility was determined by socioeconomic factors.
Amino acid sensing in hypothalamic tanycytes via umami taste receptors.
Lazutkaite, Greta; Soldà, Alice; Lossow, Kristina; Meyerhof, Wolfgang; Dale, Nicholas
2017-11-01
Hypothalamic tanycytes are glial cells that line the wall of the third ventricle and contact the cerebrospinal fluid (CSF). While they are known to detect glucose in the CSF we now show that tanycytes also detect amino acids, important nutrients that signal satiety. Ca 2+ imaging and ATP biosensing were used to detect tanycyte responses to l-amino acids. The downstream pathway of the responses was determined using ATP receptor antagonists and channel blockers. The receptors were characterized using mice lacking the Tas1r1 gene, as well as an mGluR4 receptor antagonist. Amino acids such as Arg, Lys, and Ala evoke Ca 2+ signals in tanycytes and evoke the release of ATP via pannexin 1 and CalHM1, which amplifies the signal via a P2 receptor dependent mechanism. Tanycytes from mice lacking the Tas1r1 gene had diminished responses to lysine and arginine but not alanine. Antagonists of mGluR4 greatly reduced the responses to alanine and lysine. Two receptors previously implicated in taste cells, the Tas1r1/Tas1r3 heterodimer and mGluR4, contribute to the detection of a range of amino acids by tanycytes in CSF. Copyright © 2017 The Authors. Published by Elsevier GmbH.. All rights reserved.
NASA Astrophysics Data System (ADS)
Theresia Djue Tea, Marselina; Sabarudin, Akhmad; Sulistyarti, Hermin
2018-01-01
A method for the determination of diazinon and chlorantraniliprole in soil samples has been developed. The analyte was extracted with acetonitrile from farmland soil sample. Determination and quantification of diazinon and chlorantraniliprole were perfomed by high perfomance liquid chromatography (HPLC) with an UV detector. Several parameters of HPLC method were optimized with respect to sensitivity, high resolution of separation, and accurate determination of diazinon and chlorantraniliprole. Optimum conditions for the separation of two pesticides were eluent composition of acetonitrile:water ratio of 60:40, 0.4 mL/min of flow rate, and 220 nm of wavelength. Under the optimum conditions, diazinon linearity was in the range from 1-25 ppm with R2 of 0.9976, 1.19 mgL-1 LOD, and 3.98 mgL-1 LOQ; while the linearity of chlorantraniliprole was in the range from 0.2-5 mgL-1 with R2 of 0.9972, 0.39 mgL-1 LOD, and 1.29 mgL-1 LOQ. When the method was applied to the soil sample, both pesticides showed acceptable recoveries for real sample of more than 85%: thus, the developed method meets the validation requirement. Under this developed method, the concentrations of both pesticides in the soil samples were below the LOD and LOQ (0.577 mgL-1 for diazinon and 0.007 mgL-1 for chlorantraniliprole). Therefore, it can be concluded that the soil samples used in this study have neither diazinon nor chlorantraniliprole.
NASA Astrophysics Data System (ADS)
Liu, Jia-Ming; Lin, Li-Ping; Wang, Hong-Xin; Lin, Shao-Qin; Zhang, Li-Hong; Cai, Wen-Lian; Lin, Xuan; Pan, You-Zhu; Wang, Xin-Xing; Li, Zhi-Ming; Jiao, Li; Cui, Ma-Lin
2011-12-01
Calcein (R) could not only emit strong and stable room temperature phosphorescence (RTP) on filter paper using I - as perturber, but also could be oxidized by H 2O 2 to form a non-phosphorescence compound (R'), resulting in the quenching of RTP signal of R. Moreover, the ortho-hydrogen of phenolic hydroxyl in R took condensation reaction with rhamnose (Rha) to produce non-phosphorescence compound (R-Rha) causing the RTP signal of R to further quench, and R-Rha was oxidized by H 2O 2 to form R' and Rha, bringing about the sharp RTP signal quenching of R. Thus, a new solid substrate room temperature phosphorimetry (SSRTP) for the determination of trace Rha based on its strong catalytic effect on H 2O 2 oxidizing R has been established, with the detection limit (LD) of 7.8 zg spot -1 (corresponding concentration: 2.0 × 10 -17 g ml -1, sample volume: 0.40 μl spot -1). This method has been applied to determine trace Rha in cigarettes and jujubes, with the results coinciding well with those determined by a high performance liquid chromatography (HPLC). The component of R-Rha also was analyzed by means of HPLC, mass spectrometer and nuclear magnetic resonance (NMR) measurements. The mechanism of catalytic SSRTP for the determination of trace Rha was discussed.
Su, Chong; Yang, Hong; Meng, Xiangjun; Fawcett, J Paul; Cao, Jianming; Yang, Yan; Gu, Jingkai
2017-02-01
Rabeprazole is a novel benzimidazole proton pump inhibitor used for the treatment of gastrointestinal disorders. It is a chiral molecule that gives rise to the possibility of stereoselective pharmacokinetics. To investigate this phenomenon, a rapid and sensitive chiral assay based on supercritical fluid chromatography tandem mass spectrometry was developed and applied to the determination of (R)-rabeprazole and (S)-rabeprazole in dog plasma. Sample preparation involved protein precipitation with acetonitrile after the addition of (R)-lansoprazole as internal standard. Baseline separation of enantiomers in 4.5 min was achieved on an Acquity UPC 2 system using an ACQUITY UPC 2 Trefoil CEL2 column maintained at 60°C and a mobile phase consisting of methanol/CO 2 (30:70, v/v) delivered at 2.5 mL/min. Detection was achieved by multiple reaction monitoring of the transitions at m/z 360.0→242.2 (rabeprazole) and 370.3→252.0 (internal standard) in the positive ion mode. The assay was linear in the range of 1-1000 ng/mL and free of matrix effects. Intra- and interday precisions were less than 10.0% with accuracy in the range of -2.6 to 3.1%. The method was successfully applied to a pharmacokinetic study of rabeprazole enantiomers after administration of a single oral dose of 10 mg racemate to beagle dogs. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
EMPIRICALLY ESTIMATED FAR-UV EXTINCTION CURVES FOR CLASSICAL T TAURI STARS
DOE Office of Scientific and Technical Information (OSTI.GOV)
McJunkin, Matthew; France, Kevin; Schindhelm, Eric
Measurements of extinction curves toward young stars are essential for calculating the intrinsic stellar spectrophotometric radiation. This flux determines the chemical properties and evolution of the circumstellar region, including the environment in which planets form. We develop a new technique using H{sub 2} emission lines pumped by stellar Ly α photons to characterize the extinction curve by comparing the measured far-ultraviolet H{sub 2} line fluxes with model H{sub 2} line fluxes. The difference between model and observed fluxes can be attributed to the dust attenuation along the line of sight through both the interstellar and circumstellar material. The extinction curvesmore » are fit by a Cardelli et al. (1989) model and the A {sub V} (H{sub 2}) for the 10 targets studied with good extinction fits range from 0.5 to 1.5 mag, with R {sub V} values ranging from 2.0 to 4.7. A {sub V} and R {sub V} are found to be highly degenerate, suggesting that one or the other needs to be calculated independently. Column densities and temperatures for the fluorescent H{sub 2} populations are also determined, with averages of log{sub 10}( N (H{sub 2})) = 19.0 and T = 1500 K. This paper explores the strengths and limitations of the newly developed extinction curve technique in order to assess the reliability of the results and improve the method in the future.« less
Single- and Double-Strand Breaks of Dry DNA Exposed to Protons at Bragg-Peak Energies.
Souici, Mounir; Khalil, Talat T; Muller, Dominique; Raffy, Quentin; Barillon, Rémi; Belafrites, Abdelfettah; Champion, Christophe; Fromm, Michel
2017-01-26
Ultrathin layers (<20 nm) of pBR322 plasmid DNA were deposited onto 2.5 μm thick polyester films and exposed to proton Bragg-peak energies (90-3000 keV) at various fluences. A quantitative analysis of radio-induced DNA damage is reported here in terms of single- and double-strand breaks (SSB and DSB, respectively). The corresponding yields as well as G-values and the cross sections exhibit fairly good agreement with the rare available data, stemming from close experimental conditions, namely, based on α particle irradiation. SSB/DSB rates appear to be linear when plotted against linear energy transfer (LET) in the whole energy range studied. All the data present a maximum in the 150-200 keV energy range; as for LET, it peaks at 90 keV. We also show that fragmentation starts to be significant for proton fluences greater than 1 × 10 11 cm -2 at the Bragg-peak energies. Finally, we determine the average proton track radial extension, r max , corresponding to an occupation probability of 100% DSB in the Bragg-peak region. The r max values determined are in excellent agreement with the radial extensions of proton tracks determined by simulation approaches in water. When plotted as a function of LET, both SSB and DSB cross sections bend back at high LETs.
Wu, Chia-Chang
2017-08-15
We propose a simple, rapid analytical method for determination of 89 pesticides in Oolong tea by GC/MS/MS. Samples were extracted via QuEChERS. The limits of detection and quantification range of the 89 pesticides were 1-25μgL -1 and 10-50μgL -1 , respectively. Good separation was attained in less than 36min. A wide linear range of 1-250μgL -1 was observed with r 2 values from 0.9955 to 0.9998. Pesticide-free tea powder spiked at 50 and 100μgL -1 . Recovery ranges of the 86 (50μgL -1 ) and 83 (100μgL -1 ) pesticides were from 60% to 120%. Relative standard deviations were less than 20%. The laboratory proficiency test (FAPAS, 2014) shows satisfactory (|z|<2) z-score values. The proposed monitoring technique rapidly and efficiently screens, multiple pesticides in Oolong tea. Copyright © 2017 Elsevier Ltd. All rights reserved.
Validity of the Myotest® in measuring force and power production in the squat and bench press.
Comstock, Brett A; Solomon-Hill, Glenn; Flanagan, Shawn D; Earp, Jacob E; Luk, Hui-Ying; Dobbins, Kathryn A; Dunn-Lewis, Courtenay; Fragala, Maren S; Ho, Jen-Yu; Hatfield, Disa L; Vingren, Jakob L; Denegar, Craig R; Volek, Jeff S; Kupchak, Brian R; Maresh, Carl M; Kraemer, William J
2011-08-01
The purpose of this study was to verify the concurrent validity of a bar-mounted Myotest® instrument in measuring the force and power production in the squat and bench press exercises when compared to the gold standard of a computerized linear transducer and force platform system. Fifty-four men (bench press: 39-171 kg; squat: 75-221 kg) and 43 women (bench press: 18-80 kg; squat: 30-115 kg) (age range 18-30 years) performed a 1 repetition maximum (1RM) strength test in bench press and squat exercises. Power testing consisted of the jump squat and the bench throw at 30% of each subject's 1RM. During each measurement, both the Myotest® instrument and the Celesco linear transducer of the directly interfaced BMS system (Ballistic Measurement System [BMS] Innervations Inc, Fitness Technology force plate, Skye, South Australia, Australia) were mounted to the weight bar. A strong, positive correlation (r) between the Myotest and BMS systems and a high correlation of determination (R2) was demonstrated for bench throw force (r = 0.95, p < 0.05) (R2 = 0.92); bench throw power (r = 0.96, p < 0.05) (R2 = 0.93); squat jump force (r = 0.98, p < 0.05) (R2 = 0.97); and squat jump power (r = 0.91, p < 0.05) (R2 = 0.82). In conclusion, when fixed on the bar in the vertical axis, the Myotest is a valid field instrument for measuring force and power in commonly used exercise movements.
Variation in heart rate and blood lactate concentration in freestyle kytesurfing.
Camps, A; Vercruyssen, F; Brisswalter, J
2011-06-01
The aim of this paper was to evaluate the physiological demands of freestyle kitesurfing. Ten elite subjects performed an incremental running test on a treadmill and a three 7 min simulated freestyle heats of kitesurfing in MW (Midwind) condition ranging from 15 to 22 knots. Oxygen uptake (VO(2)) was estimated from the heart rate (HR) recorded during the freestyle trial using the individual HR-VO(2) relationship determined during the incremental test. Blood lactate concentration [Lab] was measured at rest and 3 min after the exercise completion. 3 experienced kitesurfers acted as judges to better simulate competition conditions. Linear relationship was demonstrated between scores and % HR(max) on water (r=-0.764, P<0.05), HR(max) on water (r=-0.684, P<0.05) estimated VO(2) on water (r=-0.724, P<0.05), HR on water (r=0.709, P<0.05), % VO(2) on water (r=0.740, P<0.05), final [Lab] (r=-0.884, P<0.05), anaerobic threshold (AT) (r=0.836, P<0.05), HR in AT (r=0.748, P<0.05) and ranking (r=-0,924, P<0.05), mean HR and estimated VO(2) values represented, respectively 85.4±3.0% of maximal heart rate and 80.0±4.5% of maximal oxygen uptake. Mid values for [Lab] were observed at the end of crossing trial (5.2±0.8 mmol L(-1)). This first analysis of freestyle kitesurfing suggests that the energy demand is sustained by both aerobic and anaerobic metabolism during a MW condition and freestyle event of kitesurfing.
Energy expenditure and influence of physiologic factors during marathon running.
Loftin, Mark; Sothern, Melinda; Koss, Cathie; Tuuri, Georgianna; Vanvrancken, Connie; Kontos, Anthony; Bonis, Marc
2007-11-01
This study examined energy expenditure and physiologic determinants for marathon performance in recreational runners. Twenty recreational marathon runners participated (10 males aged 41 +/- 11.3 years, 10 females aged 42.7 +/- 11.7 years). Each subject completed a V(.-)O2max and a 1-hour treadmill run at recent marathon pace, and body composition was indirectly determined via dual energy X-ray absorptiometry. The male runners exhibited higher V(.-)O2max (ml x kg(-1) x min(-1)) values (52.6 +/- 5.5) than their female counterparts (41.9 +/- 6.6), although ventilatory threshold (T-vent) values were similar between groups (males: 76.2 +/- 6.1 % of V(.-)O2max, females: 75.1 +/- 5.1%). The male runners expended more energy (2,792 +/- 235 kcal) for their most recent marathon as calculated from the 1-hour treadmill run at marathon pace than the female runners (2,436 +/- 297 kcal). Body composition parameters correlated moderately to highly (r ranging from 0.50 to 0.87) with marathon run time. Also, V(.-)O2max (r = -0.73) and ventilatory threshold (r = -0.73) moderately correlated with marathon run time. As a group, the participants ran near their ventilatory threshold for their most recent marathon (r = 0.74). These results indicate the influence of body size on marathon run performance. In general, the larger male and female runners ran slower and expended more kilocalories than smaller runners. Regardless of marathon finishing time, the runners maintained a pace near their T-vent, and as T-vent or V(.-)O2max increased, marathon performance time decreased.
Mg2+ activates the ryanodine receptor type 2 (RyR2) at intermediate Ca2+ concentrations.
Chugun, Akihito; Sato, Osamu; Takeshima, Hiroshi; Ogawa, Yasuo
2007-01-01
To clarify whether activity of the ryanodine receptor type 2 (RyR2) is reduced in the sarcoplasmic reticulum (SR) of cardiac muscle, as is the case with the ryanodine receptor type 1 (RyR1), Ca(2+)-dependent [(3)H]ryanodine binding, a biochemical measure of Ca(2+)-induced Ca(2+) release (CICR), was determined using SR vesicle fractions isolated from rabbit and rat cardiac muscles. In the absence of an adenine nucleotide or caffeine, the rat SR showed a complicated Ca(2+) dependence, instead of the well-documented biphasic dependence of the rabbit SR. In the rat SR, [(3)H]ryanodine binding initially increased as [Ca(2+)] increased, with a plateau in the range of 10-100 microM Ca(2+), and thereafter further increased to an apparent peak around 1 mM Ca(2+), followed by a decrease. In the presence of these modulators, this complicated dependence prevailed, irrespective of the source. Addition of 0.3-1 mM Mg(2+) unexpectedly increased the binding two- to threefold and enhanced the affinity for [(3)H]ryanodine at 10-100 microM Ca(2+), resulting in the well-known biphasic dependence. In other words, the partial suppression of RyR2 is relieved by Mg(2+). Ca(2+) could be a substitute for Mg(2+). Mg(2+) also amplifies the responses of RyR2 to inhibitory and stimulatory modulators. This stimulating effect of Mg(2+) on RyR2 is entirely new, and is referred to as the third effect, in addition to the well-known dual inhibitory effects. This effect is critical to describe the role of RyR2 in excitation-contraction coupling of cardiac muscle, in view of the intracellular Mg(2+) concentration.
Black carbon cookstove emissions: A field assessment of 19 stove/fuel combinations
NASA Astrophysics Data System (ADS)
Garland, Charity; Delapena, Samantha; Prasad, Rajendra; L'Orange, Christian; Alexander, Donee; Johnson, Michael
2017-11-01
Black carbon (BC) emissions from household cookstoves consuming solid fuel produce approximately 25 percent of total anthropogenic BC emissions. The short atmospheric lifetime of BC means that reducing BC emissions would result in a faster climate response than mitigating CO2 and other long-lived greenhouse gases. This study presents the results of optical BC measurements of two new cookstove emissions field assessments and 17 archived cookstove datasets. BC was determined from attenuation of 880 nm light, which is strongly absorbed by BC, and linearly related between 1 and 125 attenuation units. A relationship was experimentally determined correlating BC mass deposition on quartz filters determined via thermal optical analysis (TOA) and on PTFE and quartz filters using transmissometry, yielding an attenuation cross-section (σATN) for both filter media types. σATN relates TOA measurements to optical measurements on PTFE and quartz (σATN(PTFE) = 13.7 cm-2 μg, R2 = 0.87, σATN(Quartz) = 15.6 cm-2 μg, R2 = 0.87). These filter-specific σATN, optical measurements of archived filters were used to determine BC emission factors and the fraction of particulate matter (PM) in the form of black carbon (BC/PM). The 19 stoves measured fell into five stove classes; simple wood, rocket, advanced biomass, simple charcoal, and advanced charcoal. Advanced biomass stoves include forced- and natural-draft gasifiers which use wood or biomass pellets as fuel. Of these classes, the simple wood and rocket stoves demonstrated the highest median BC emission factors, ranging from 0.051 to 0.14 g MJ-1. The lowest BC emission factors were seen in charcoal stoves, which corresponds to the generally low PM emission factors observed during charcoal combustion, ranging from 0.0084 to 0.014 g MJ-1. The advanced biomass stoves generally showed an improvement in BC emissions factors compared to simple wood and rocket stoves, ranging from 0.0031 to 0.071 g MJ-1. BC/PM ratios were highest for the advanced and rocket stoves. Potential relative climate impacts were estimated by converting aerosol emissions to CO2-equivalent, and suggest that some advanced stove/fuel combinations could provide substantial climate benefits.
Photometry of Polar-Ring Galaxies
NASA Astrophysics Data System (ADS)
Godínez-Martínez, A.; Watson, A. M.; Matthews, L. D.; Sparke, L. S.
2007-10-01
We have obtained photometry in B and R for seven confirmed or probable polar-ring galaxies from the Polar-Ring Catalog of Whitmore et al. (1990). The rings show a range of colors from B - R ≈ 0.6 to B - R ≈ 1.7. The bluest rings have bright H II regions, which are direct evidence for recent star formation. The minimum age of the reddest ring, that in PRC B-20, is somewhat uncertain because of a lack of knowledge of the internal reddening and metallicity, but appears to be at least 1.2 Gyr. As such, this ring is likely to be stable for at least several rotation periods. This ring is an excellent candidate for future studies that might better determine if it is truly old.
Thakur, Ashish; Kadam, Rajendra S.
2011-01-01
The influence of drug properties including solubility, lipophilicity, tissue partition coefficients, and in vitro transscleral permeability on ex vivo and in vivo transscleral delivery from corticosteroid suspensions was determined. Solubility, tissue/buffer partition coefficients for bovine sclera and choroid-retinal pigment epithelium (CRPE), and in vitro bovine sclera and sclera-choroid-retinal pigment epithelium (SCRPE) transscleral transport were determined at pH 7.4 for triamcinolone, prednisolone, dexamethasone, fluocinolone acetonide, triamcinolone acetonide, and budesonide in solution. Ex vivo and in vivo transscleral delivery was assessed in Brown Norway rats after posterior subconjunctival injection of a 1 mg/ml suspension of each corticosteroid. Corticosteroid solubility and partition coefficients ranged from ∼17 to 300 μg/ml and 3.0 to 11.4 for sclera and from 7.1 to 35.8 for CRPE, respectively, with the more lipophilic molecules partitioning more into both tissues. Transport across sclera and SCRPE was in the range of 3.9 to 10.7% and 0.3 to 1.8%, respectively, with the transport declining with an increase in lipophilicity. Ex vivo and in vivo transscleral delivery indicated tissue distribution in the order CRPE ≥ sclera > retina > vitreous. Tissue partitioning showed a positive correlation with drug lipophilicity (R2 = 0.66–0.96). Ex vivo and in vivo sclera, CRPE, retina, and vitreous tissue levels of all corticosteroids showed strong positive correlation with drug solubility (R2 = 0.91–1.0) but not lipophilicity (R2 = 0.24–0.41) or tissue partitioning (R2 = 0.24–0.46) when delivered as suspensions. In vivo delivery was lower in all eye tissues assessed than ex vivo delivery, with the in vivo/ex vivo ratios being the lowest in the vitreous (0.085–0.212). Upon exposure to corticosteroid suspensions ex vivo or in vivo, transscleral intraocular tissue distribution was primarily driven by the drug solubility. PMID:21346004
The Sleep EEG as a Marker of Intellectual Ability in School Age Children
Geiger, Anja; Huber, Reto; Kurth, Salomé; Ringli, Maya; Jenni, Oskar G.; Achermann, Peter
2011-01-01
Study Objectives: To investigate the within-subject stability in the sleep EEG and the association between the sleep EEG and intellectual abilities in 9- to 12-year-old children. Design: Intellectual ability (WISC-IV, full scale, fluid, and verbal IQ, working memory, speed of processing) were examined and all-night polysomnography was performed (2 nights per subject). Setting: Sleep laboratory. Participants: Fourteen healthy children (mean age 10.5 ± 1.0 years; 6 girls). Measurements and Results: Spectral analysis was performed on artifact-free NREM sleep epochs (C3/A2). To determine intra-individual stability and inter-individual variability of the sleep EEG, power spectra were used as feature vectors for the estimation of Euclidean distances, and intraclass correlation coefficients (ICC) were calculated for the 2 nights. Sleep spindle peaks were identified for each individual and individual sigma band power was determined. Trait-like aspects of the sleep EEG were observed for sleep stage variables and spectral power. Within-subject distances were smaller than between-subject distances and ICC values ranged from 0.72 to 0.96. Correlations between spectral power in individual frequency bins and intelligence scores revealed clusters of positive associations in the alpha, sigma, and beta range for full scale IQ, fluid IQ, and working memory. Similar to adults, sigma power correlated with full scale (r = 0.67) and fluid IQ (r = 0.65), but not with verbal IQ. Spindle peak frequency was negatively related to full scale IQ (r = −0.56). Conclusions: The sleep EEG during childhood shows high within-subject stability and may be a marker for intellectual ability. Citation: Geiger A; Huber R; Kurth S; Ringli M; Jenni OG; Achermann P. The sleep EEG as a marker of intellectual ability in school age children. SLEEP 2011;34(2):181-189. PMID:21286251
NASA Astrophysics Data System (ADS)
El-Shabaan, M. M.
2018-05-01
Thermal, structural, alternating-current (AC) conductivity (σ AC), and dielectric properties of ethyl-2-amino-6-ethyl-5-oxo-4-(3-phenoxyphenyl)-5,6-dihydro-4H-pyrano[3,2-c]quinoline-3-carboxylate (HPQC) thin films have been studied. Thermogravimetry analysis and differential scanning calorimetry confirmed the thermal stability of HPQC over a wide temperature range. Fourier-transform infrared spectroscopy and x-ray diffraction analysis were carried out on HPQC in powder form and as-deposited thin film. The crystal system and space group type were determined for HPQC in powder form. The AC conductivity and dielectric properties were determined in the frequency range from 0.5 kHz to 5 MHz and temperature range from 296 K to 443 K. The AC electrical conduction of HPQC thin film was found to be governed by the small-polaron tunneling mechanism. The polaron hopping energy (W H), tunneling distance (R), and density of states (N) near the Fermi level were determined as functions of temperature and frequency. The dielectric properties of HPQC thin film were studied by analysis of Nyquist diagrams, the dissipation factor (tan δ), and real (ɛ') and imaginary (ɛ″) parts of the dielectric constant.
A cost/benefit analysis of commercial fusion-fission hybrid reactor development
NASA Astrophysics Data System (ADS)
Kostoff, Ronald N.
1983-04-01
A simple algorithm was developed that allows rapid computation of the ratio, R, of present worth of benefits to present worth of hybrid R&D program costs as a function of potential hybrid unit electricity cost savings, discount rate, electricity demand growth rate, total hybrid R&D program cost, and time to complete a demonstration reactor. In the sensitivity study, these variables were assigned nominal values (unit electricity cost savings of 4 mills/kW-hr, discount rate of 4%/year, growth rate of 2.25%/year, total R&D program cost of 20 billion, and time to complete a demonstration reactor of 30 years), and the variable of interest was varied about its nominal value. Results show that R increases with decreasing discount rate and increasing unit electricity savings and ranges from 4 to 94 as discount rate ranges from 5 to 3%/year and unit electricity savings range from 2 to 6 mills/kW-hr. R increases with increasing growth rate and ranges from 3 to 187 as growth rate ranges from 1 to 3.5%/year and unit electricity cost savings range from 2 to 6 mills/kW-hr. R attains a maximum value when plotted against time to complete a demonstration reactor. The location of this maximum value occurs at shorter completion times as discount rate increases, and this optimal completion time ranges from 20 years for a discount rate of 4%/year to 45 years for a discount rate of 3%/year.
Guyon, François; Gaillard, Laetitia; Salagoïty, Marie-Hélène; Médina, Bernard
2011-09-01
High-performance liquid chromatography linked to isotope ratio mass spectrometry (HPLC-co-IRMS) via a Liquiface© interface has been used to simultaneously determine (13)C isotope ratios of glucose (G), fructose (F), glycerol (Gly) and ethanol (Eth) in sweet and semi-sweet wines. The data has been used the study of wine authenticity. For this purpose, 20 authentic wines from various French production areas and various vintages have been analyzed after dilution in pure water from 20 to 200 times according to sugar content. If the (13)C isotope ratios vary according to the production area and the vintage, it appears that internal ratios of (13)C isotope ratios (R((13)C)) of the four compounds studied can be considered as a constant. Thus, ratios of isotope ratios are found to be 1.00 ± 0.04 and 1.02 ± 0.08 for R((13)C(G/F)) and R((13)C(Gly/Eth)), respectively. Moreover, R((13)C(Eth/Sugar)) is found to be 1.15 ± 0.10 and 1.16 ± 0.08 for R((13)C(Gly/Sugar)). Additions of glucose, fructose and glycerol to a reference wine show a variation of the R((13)C) value for a single product addition as low as 2.5 g/L(-1). Eighteen commercial wines and 17 concentrated musts have been analyzed. Three wine samples are suspicious as the R((13)C) values are out of range indicating a sweetening treatment. Moreover, concentrated must analysis shows that (13)C isotope ratio can be also used directly to determine the authenticity of the matrix.
[Determination of 5 nucleosides components in culture of Paecilomyces hepialid by HPLC].
Yang, Dan; Ma, Yun-shu; Huang, Ting-ting; Chen, Cheng
2015-08-01
The concentration of 5 nucleosides, uracil, uridine, guanidine, adenine and adenosine in culture of Paecilomyces hepialid was determined by the developed method of HPLC. The HPLC method was performed on a Waters SunFire C18 (4.6 mm x 250 mm, 5 μm) column with methanol-water gradient elution as the mobile phase. The detection wavelength was 260 nm and the colunmn temperature was controlled at 30 °C. The linear range was 10.00-200.00 mg · L(-1) (r = 0.9994) for uracil, 10.10-202.00 mg · L(-1) (r = 0.9992) for uridine, 10.00-200.00 mg · L(-1) (r = 0.9991) for guanidine, 10.30-206.00 mg · L(-1) (r = 0.9992) for adenine and 10.45-209.00 mg · L(-1) (r = 0.9991) for adenosine, respectively. The RSD of precision was 0.032%, 0.035%, 0.039%, 0.049%, 0.00080%, respectively. The average recoveries of uracil, guanidine, adenine, and adenosine were 97.34%, 99.10%, 101.6%, 98.61% and 100.2% with RSD of 1.3%, 2.1%, 0.96%, 0.95%, and 1.3% respectively. The method showed high sensitivity, good selectivity, linearity and repeatability, which was suitable for the content analysis of 5 nucleosides components in P. hepialid and its extracts.
Evaluating diagnosis-based risk-adjustment methods in a population with spinal cord dysfunction.
Warner, Grace; Hoenig, Helen; Montez, Maria; Wang, Fei; Rosen, Amy
2004-02-01
To examine performance of models in predicting health care utilization for individuals with spinal cord dysfunction. Regression models compared 2 diagnosis-based risk-adjustment methods, the adjusted clinical groups (ACGs) and diagnostic cost groups (DCGs). To improve prediction, we added to our model: (1) spinal cord dysfunction-specific diagnostic information, (2) limitations in self-care function, and (3) both 1 and 2. Models were replicated in 3 populations. Samples from 3 populations: (1) 40% of veterans using Veterans Health Administration services in fiscal year 1997 (FY97) (N=1,046,803), (2) veteran sample with spinal cord dysfunction identified by codes from the International Statistical Classification of Diseases, 9th Revision, Clinical Modifications (N=7666), and (3) veteran sample identified in Veterans Affairs Spinal Cord Dysfunction Registry (N=5888). Not applicable. Inpatient, outpatient, and total days of care in FY97. The DCG models (R(2) range,.22-.38) performed better than ACG models (R(2) range,.04-.34) for all outcomes. Spinal cord dysfunction-specific diagnostic information improved prediction more in the ACG model than in the DCG model (R(2) range for ACG,.14-.34; R(2) range for DCG,.24-.38). Information on self-care function slightly improved performance (R(2) range increased from 0 to.04). The DCG risk-adjustment models predicted health care utilization better than ACG models. ACG model prediction was improved by adding information.
VizieR Online Data Catalog: Abundance analysis of 9 very metal-poor stars (O'Malley+, 2017)
NASA Astrophysics Data System (ADS)
O'Malley, E. M.; McWilliam, A.; Chaboyer, B.; Thompson, I.
2017-10-01
We were awarded time on HST to obtain fine guidance sensor (FGS) parallaxes of nine very metal-poor stars with the goal of extending the range of metallicities below at least [Fe/H]=-2.3dex for stars with well-determined parallaxes. High-resolution spectroscopy of the nine target stars were obtained between 2008 and 2012 using the Magellan Inamori Kyocera Echelle (MIKE) double spectrograph on the 6.5m Magellan II Clay Telescope at Las Campanas Observatory, Chile (R=48000 for the red side and R=55000 for the blue side), and the High-Resolution Echelle Spectrometer (HiRES) on the twin telescopes at the W. M. Keck Observatory (R~70500). A log of the spectroscopic observations along with the HST F606W magnitudes and parallaxes appears in Table 1. (5 data files).
Strambini, Giovanni B.; Gonnelli, Margherita
2010-01-01
Quenching of Trp phosphorescence in proteins by diffusion of solutes of various molecular sizes unveils the frequency-amplitude of structural fluctuations. To cover the sizes gap between O2 and acrylamide, we examined the potential of acrylonitrile to probe conformational flexibility of proteins. The distance dependence of the through-space acrylonitrile quenching rate was determined in a glass at 77 K, with the indole analog 2-(3-indoyl) ethyl phenyl ketone. Intensity and decay kinetics data were fitted to a rate, k(r) = k0 exp[−(r − r0)/re], with an attenuation length re = 0.03 nm and a contact rate k0 = 3.6 × 1010 s−1. At ambient temperature, the bimolecular quenching rate constant (kq) was determined for a series of proteins, appositely selected to test the importance of factors such as the degree of Trp burial and structural rigidity. Relative to kq = 1.9 × 109 M−1s−1 for free Trp in water, in proteins kq ranged from 6.5 × 106 M−1s−1 for superficial sites to 1.3 × 102 M−1s−1 for deep cores. The short-range nature of the interaction and the direct correlation between kq and structural flexibility attest that in the microsecond-second timescale of phosphorescence acrylonitrile readily penetrates even compact protein cores and exhibits significant sensitivity to variations in dynamical structure of the globular fold. PMID:20682273
Bamdad, Farzad; Khorram, Fateme; Samet, Maryam; Bamdad, Kourosh; Sangi, Mohammad Reza; Allahbakhshi, Fateme
2016-05-15
In this article a simple and selective colorimetric probe for cysteine determination using silver nano particles (AgNPS) is described. The determination process was based upon the surface plasmon resonance properties of polyvinylpyrrolidone-stabilized AgNPS. Interaction of AgNPS with cysteine molecules in the presence of barium ions induced a red shift in the surface plasmon resonance (SPR) maximum of AgNPs, as a result of nanoparticle aggregation. Consequently, yellow color of AgNP solution was changed to pink. The linear range for the determination of cysteine was 3.2-8.2 μM (R=0.9965) with a limit of detection equal to 2.8 μM (3σ). The proposed method was successfully applied to the determination of cysteine in human plasma samples. Acceptable recovery results of the spiked samples confirmed the validity of the proposed method. Copyright © 2016 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Bamdad, Farzad; Khorram, Fateme; Samet, Maryam; Bamdad, Kourosh; Sangi, Mohammad Reza; Allahbakhshi, Fateme
2016-05-01
In this article a simple and selective colorimetric probe for cysteine determination using silver nano particles (AgNPS) is described. The determination process was based upon the surface plasmon resonance properties of polyvinylpyrrolidone-stabilized AgNPS. Interaction of AgNPS with cysteine molecules in the presence of barium ions induced a red shift in the surface plasmon resonance (SPR) maximum of AgNPs, as a result of nanoparticle aggregation. Consequently, yellow color of AgNP solution was changed to pink. The linear range for the determination of cysteine was 3.2-8.2 μM (R = 0.9965) with a limit of detection equal to 2.8 μM (3σ). The proposed method was successfully applied to the determination of cysteine in human plasma samples. Acceptable recovery results of the spiked samples confirmed the validity of the proposed method.
1984-02-01
of Cost Analysis Worksheets * POD Program-Economic Analysis & Methodology - Economic Evaluation Procedures for POD Investment Program - System...Approval Considerations - POD Investment Program - Potential Improvement Areas for POD - Example Cost Categories and Determinants Appendix E Long Range R&D...Funding Profiles * Investment Strategy for Integrated Circuits Diminishing Sources of Supply - Problem Scope - Approach - Alternatives - Proposed
Disparity between Physical Capacity and Participation in Seniors with Chronic Disease
Ashe, Maureen C.; Eng, Janice J.; Miller, William C.; Soon, Judith A.
2011-01-01
Consistently low rates of physical activity are reported for older adults and there is even lower participation if a chronic disease is present. Purpose To explore the predictors of physical capacity and participation in older community-dwelling individuals living with multiple chronic diseases. Methods This was a descriptive cross-sectional investigation of physical capacity (physiological potential) and physical activity participation (recorded engagement in physical activity). Multiple regression and odds ratios were used to investigate determinants of physical capacity (6 Minute Walk Test) and physical activity participation (Physical Activity Scale for Individuals with Physical Disabilities Questionnaire; pedometer steps/day). Results 200 community dwelling ambulatory participants living with 2 or more chronic disease were assessed. Sixty-five percent (65%) were women and the mean age was 74 ± 6 years (range 65–90 years). Mobility (Timed Up and Go) was a consistent determinant across all 3 primary outcomes. For the Six Minute Walk Test, determinants included mobility, BMI, grip strength, number of medications, leg strength, balance and Chronic Disease Management Self Efficacy Scale (r2=0.58; P=.000). The determinants for the self-reported participation measure (Physical Activity Scale for Individuals with Physical Disabilities Questionnaire) was mobility (r2=0.04; P=.007). For the mean daily pedometer steps, the determinants included mobility, body mass index (BMI), age and Chronic Disease Management Self-Efficacy Scale (r2=0.27; P=.000). There were higher risks for inactivity associated with impairments compared with the presence of a chronic disease. In addition, over 1/3 of participants had sufficient physical capacity, but did not meet minimal recommendations of physical activity. Conclusion This study suggests that it is easier to predict an individual’s physical capacity than their actual physical participation. PMID:17596782
Wu, Che-Wei; Hao, Min; Tian, Mengzi; Dionigi, Gianlorenzo; Tufano, Ralph P; Kim, Hoon Yub; Jung, Kwang Yoon; Liu, Xiaoli; Sun, Hui; Lu, I-Cheng; Chang, Pi-Ying; Chiang, Feng-Yu
2017-06-01
During monitored thyroidectomy, a partially or completely disrupted point of nerve conduction on the exposed recurrent laryngeal nerve (RLN) indicates true electrophysiologic nerve injury. Complete loss of signal (LOS; absolute threshold value <100 μV) at the end of operation often indicates a postoperative vocal cord (VC) palsy. However, the evaluation for the injured RLN with incomplete LOS and its functional outcome has not been well described. Three hundred twenty-three patients with 522 RLNs at risk who underwent standardized monitored thyroidectomy were enrolled. The RLN was routinely stimulated at the most proximal (R 2p signal) and distal (R 2d signal) ends of exposure after thyroid resection to determine if there was an injured point on the RLN. Pre- and postoperative VC function was routinely examined. Twenty-nine RLNs (5.6 %) were detected with an injury point. Five nerves had complete LOS and other 24 nerves had incomplete LOS where the R 2p /R 2d reduction (% of amplitude reduction compared with proximal to distal RLN stimulation) ranged from 22 to 79 %. Postoperative temporary VC palsy was noted in those five RLNs with complete LOS (final vagal signal, V 2 < 100 μV) and four RLNs with incomplete LOS (R 2p /R 2d reduction 62-79 %; V 2 181-490 μV). In the remaining 20 nerves with R 2p /R 2d reduction ≤53 % (V 2 373-1623 μV), all showed normal VC mobility. Overall, false negative results were found in two RLNs (0.4 %) featuring unchanged V 2 and R 2p /R 2d but developed VC palsy. Testing and comparing the R 2p /R 2d signal is a simple and useful procedure to evaluate RLN injury after its dissection and predict functional outcome. When the relative threshold value R 2p /R 2d reduction reaches over 60 %, surgeon should consider the possibility of postoperative VC palsy.
Computational design of nanoparticle drug delivery systems for selective targeting
NASA Astrophysics Data System (ADS)
Duncan, Gregg A.; Bevan, Michael A.
2015-09-01
Ligand-functionalized nanoparticles capable of selectively binding to diseased versus healthy cell populations are attractive for improved efficacy of nanoparticle-based drug and gene therapies. However, nanoparticles functionalized with high affinity targeting ligands may lead to undesired off-target binding to healthy cells. In this work, Monte Carlo simulations were used to quantitatively determine net surface interactions, binding valency, and selectivity between targeted nanoparticles and cell surfaces. Dissociation constant, KD, and target membrane protein density, ρR, are explored over a range representative of healthy and cancerous cell surfaces. Our findings show highly selective binding to diseased cell surfaces can be achieved with multiple, weaker affinity targeting ligands that can be further optimized by varying the targeting ligand density, ρL. Using the approach developed in this work, nanomedicines can be optimally designed for exclusively targeting diseased cells and tissues.Ligand-functionalized nanoparticles capable of selectively binding to diseased versus healthy cell populations are attractive for improved efficacy of nanoparticle-based drug and gene therapies. However, nanoparticles functionalized with high affinity targeting ligands may lead to undesired off-target binding to healthy cells. In this work, Monte Carlo simulations were used to quantitatively determine net surface interactions, binding valency, and selectivity between targeted nanoparticles and cell surfaces. Dissociation constant, KD, and target membrane protein density, ρR, are explored over a range representative of healthy and cancerous cell surfaces. Our findings show highly selective binding to diseased cell surfaces can be achieved with multiple, weaker affinity targeting ligands that can be further optimized by varying the targeting ligand density, ρL. Using the approach developed in this work, nanomedicines can be optimally designed for exclusively targeting diseased cells and tissues. Electronic supplementary information (ESI) available: Movie showing simulation renderings of targeted (ρL = 1820/μm2, KD = 120 μM) nanoparticle selective binding to cancer (ρR = 256/μm2) vs. healthy (ρR = 64/μm2) cell surfaces. Target membrane proteins have linear color scale depending on binding energy ranging from white when unbound (URL = 0) to red when tightly bound (URL = UM). See DOI: 10.1039/c5nr03691g
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ben-David, Merav A.; Griffith, Kent A.; Abu-Isa, Eyad
Purpose: The role of radiation therapy (RT) in extrahepatic cholangiocarcinoma (EHCC) is not clear and only limited reports exist on the use of this modality. We have reviewed our institutional experience to determine the pattern of failure in patients after potentially curative resection and the expected outcomes after adjuvant RT and in unresectable patients. Methods and Materials: After institutional review board approval, 81 patients diagnosed with EHCC (gallbladder 28, distal bile duct 24, hilar 29) between June 1986 and December 2004 were identified and their records reviewed. Twenty-eight patients (35%) underwent potentially curative resection with R0/R1 margins. Fifty-two patients (64%)more » were unresectable or underwent resection with macroscopic residual disease (R2). All patients received three-dimensional planned megavoltage RT. The dose for each patient was converted to the equivalent total dose in a 2 Gy/fraction, using the linear-quadratic formalism and {alpha}/{beta} ratio of 10. The median dose delivered was 58.4 Gy (range, 23-88.2 Gy). 54% received concomitant chemotherapy. Results: With a median follow-up time of 1.2 years (range, 0.1-9.8 years) 75 patients (93%) have died. Median overall survival (OS) and progression-free survival (PFS) were 14.7 (95% CI, 13.1-16.3) and 11 (95% CI, 7.6-13.2) months, respectively. There was no difference among the three disease sites in OS (p = 0.70) or PFS (p = 0.80). Complete resection (R0) was the only predictive factor significantly associated with increase in both OS and PFS (p = 0.002), and there was no difference in outcomes between R1 and R2 resections. The first site of failure was predominantly locoregional (68.8% of all failures). Conclusion: Local failure is a major problem in EHCC, suggesting the need for more intense radiation schedules and better radiosensitizing strategies. Because R1 resection appears to convey no benefit, it appears that surgery should be contemplated only when an R0 resection is likely. Borderline-resectable patients might be better served by neoadjuvant therapy.« less
Evaluation of adrenocortical function in Florida manatees (Trichechus manatus latirostris)
Tripp, K.M.; Verstegen, J.P.; Deutsch, C.; Bonde, Robert K.; de Wit, M.; Manire, Charles A.; Gaspard, J.; Harr, K.E.
2011-01-01
The study objectives were to determine the predominant manatee glucocorticoid; validate assays to measure this glucocorticoid and adrenocorticotropic hormone (ACTH); determine diagnostic thresholds to distinguish physiological vs. pathological concentrations; identify differences associated with sex, age class, female reproductive status, capture time, and lactate; and determine the best methods for manatee biologists and clinicians to diagnose stress. Cortisol is the predominant manatee glucocorticoid. IMMULITE 1000 assays for cortisol and ACTH were validated. Precision yielded intra- and inter-assay coefficients of variation for serum cortisol: ≤23.5 and ≤16.7%; and ACTH: ≤6.9 and ≤8.5%. Accuracy resulted in a mean adjusted R(2)≥0.87 for serum cortisol and ≥0.96 for ACTH. Assay analytical sensitivities for cortisol (0.1 µg/dl) and ACTH (10.0 pg/ml) were verified. Methods were highly correlated with another IMMULITE 1000 for serum cortisol (r=0.97) and ACTH (r=0.98). There was no significant variation in cortisol or ACTH with sex or age class and no correlation with female progesterone concentrations. Cortisol concentrations were highest in unhealthy manatees, chronically stressed by disease or injury. ACTH was greatest in healthy free-ranging or short-term rehabilitating individuals, peracutely stressed by capture and handling. Cortisol concentrations ≥1.0 µg/dl were diagnostic of chronic stress; ACTH concentrations ≥87.5 pg/ml were diagnostic of peracute stress. In healthy long-term captive manatees, cortisol (0.4±0.2 µg/dl) and ACTH (47.7±15.9 pg/ml) concentrations were lower than healthy free-ranging, short-term rehabilitated or unhealthy manatees. Capture time was not significantly correlated with cortisol; ACTH correlation was borderline significant. Cortisol and ACTH were positively correlated with lactate.
Evaluation of adrenocortical function in Florida manatees (Trichechus manatus latirostris).
Tripp, Kathleen M; Verstegen, John P; Deutsch, Charles J; Bonde, Robert K; de Wit, Martine; Manire, Charles A; Gaspard, Joseph; Harr, Kendal E
2011-01-01
The study objectives were to determine the predominant manatee glucocorticoid; validate assays to measure this glucocorticoid and adrenocorticotropic hormone (ACTH); determine diagnostic thresholds to distinguish physiological vs. pathological concentrations; identify differences associated with sex, age class, female reproductive status, capture time, and lactate; and determine the best methods for manatee biologists and clinicians to diagnose stress. Cortisol is the predominant manatee glucocorticoid. IMMULITE 1000 assays for cortisol and ACTH were validated. Precision yielded intra- and inter-assay coefficients of variation for serum cortisol: ≤23.5 and ≤16.7%; and ACTH: ≤6.9 and ≤8.5%. Accuracy resulted in a mean adjusted R(2)≥0.87 for serum cortisol and ≥0.96 for ACTH. Assay analytical sensitivities for cortisol (0.1 µg/dl) and ACTH (10.0 pg/ml) were verified. Methods were highly correlated with another IMMULITE 1000 for serum cortisol (r=0.97) and ACTH (r=0.98). There was no significant variation in cortisol or ACTH with sex or age class and no correlation with female progesterone concentrations. Cortisol concentrations were highest in unhealthy manatees, chronically stressed by disease or injury. ACTH was greatest in healthy free-ranging or short-term rehabilitating individuals, peracutely stressed by capture and handling. Cortisol concentrations ≥1.0 µg/dl were diagnostic of chronic stress; ACTH concentrations ≥87.5 pg/ml were diagnostic of peracute stress. In healthy long-term captive manatees, cortisol (0.4±0.2 µg/dl) and ACTH (47.7±15.9 pg/ml) concentrations were lower than healthy free-ranging, short-term rehabilitated or unhealthy manatees. Capture time was not significantly correlated with cortisol; ACTH correlation was borderline significant. Cortisol and ACTH were positively correlated with lactate. © 2010 Wiley-Liss, Inc.
Hiranita, Takato; Soto, Paul L; Kohut, Stephen J; Kopajtic, Theresa; Cao, Jianjing; Newman, Amy H; Tanda, Gianluigi; Katz, Jonathan L
2011-11-01
Sigma receptor (σR) antagonists attenuate many behavioral effects of cocaine but typically not its reinforcing effects in self-administration procedures. However, the σR antagonist rimcazole and its N-propylphenyl analogs, [3-(cis-3,5-dimethyl-4-[3-phenylpropyl]-1-piperazinyl)-propyl]diphenylamine hydrochloride (SH 3-24) and 9-[3-(cis-3,5-dimethyl-4-[3-phenylpropyl]-1-piperazinyl)-propyl]carbazole hydrobromide (SH 3-28), dose-dependently decreased the maximal rates of cocaine self-administration without affecting comparable responding maintained by food reinforcement. In contrast, a variety of σR antagonists [N-phenethylpiperidine oxalate (AC927), N-[2-(3,4-dichlorophenyl)ethyl]-N-methyl-2-(1-pyrrolidinyl)ethylamine dihydrobromide (BD 1008), N-[2-(3,4-dichlorophenyl)ethyl]-N-methyl-2-(dimethylamino) ethylamine dihydrobromide (BD 1047), N-[2-(3,4-dichlorophenyl) ethyl]-4-methylpiperazine dihydrochloride (BD 1063), and N,N-dipropyl-2-[4-methoxy-3-(2-phenylethoxy)phenyl]-ethylamine monohydrochloride (NE-100)] had no effect on cocaine self-administration across the range of doses that decreased rates of food-maintained responding. Rimcazole analogs differed from selective σR antagonists in their dual affinities for σRs and the dopamine transporter (DAT) assessed with radioligand binding. Selective DAT inhibitors and σR antagonists were studied alone and in combination on cocaine self-administration to determine whether actions at both σRs and the DAT were sufficient to reproduce the effects of rimcazole analogs. Typical DAT inhibitors [2β-carbomethoxy-3β-(4-fluorophenyl)tropane (WIN 35,428), methylphenidate, and nomifensine] dose-dependently shifted the cocaine dose-effect curve leftward. Combinations of DAT inhibitor and σR antagonist doses that were behaviorally inactive alone decreased cocaine self-administration without effects on food-maintained responding. In addition, whereas the DAT inhibitors were self-administered at rates similar to those of cocaine, neither rimcazole analogs nor typical σR antagonists (NE-100 and AC927) maintained responding above control levels across a wide range of doses. These findings suggest that the unique effects of rimcazole analogs are due to dual actions at the DAT and σRs and that a combined target approach may have utility in development of medical treatments for cocaine abuse.
Aszyk, Justyna; Kot, Jacek; Tkachenko, Yurii; Woźniak, Michał; Bogucka-Kocka, Anna; Kot-Wasik, Agata
2017-04-15
A simple, fast, sensitive and accurate methodology based on a LLE followed by liquid chromatography-tandem mass spectrometry for simultaneous determination of four regioisomers (8-iso prostaglandin F 2α , 8-iso-15(R)-prostaglandin F 2α , 11β-prostaglandin F 2α , 15(R)-prostaglandin F 2α ) in routine analysis of human plasma samples was developed. Isoprostanes are stable products of arachidonic acid peroxidation and are regarded as the most reliable markers of oxidative stress in vivo. Validation of method was performed by evaluation of the key analytical parameters such as: matrix effect, analytical curve, trueness, precision, limits of detection and limits of quantification. As a homoscedasticity was not met for analytical data, weighted linear regression was applied in order to improve the accuracy at the lower end points of calibration curve. The detection limits (LODs) ranged from 1.0 to 2.1pg/mL. For plasma samples spiked with the isoprostanes at the level of 50pg/mL, intra-and interday repeatability ranged from 2.1 to 3.5% and 0.1 to 5.1%, respectively. The applicability of the proposed approach has been verified by monitoring of isoprostane isomers level in plasma samples collected from young patients (n=8) subjected to hyperbaric hyperoxia (100% oxygen at 280kPa(a) for 30min) in a multiplace hyperbaric chamber. Copyright © 2017 Elsevier B.V. All rights reserved.
Baryon acoustic oscillations in the Ly α forest of BOSS DR11 quasars
Delubac, Timothée; Bautista, Julian E.; Busca, Nicolás G.; ...
2015-01-26
We report a detection of the baryon acousticoscillation (BAO) feature in the flux-correlation function of the Lyα forest of high-redshift quasars with a statistical significance of five standard deviations. The study uses 137,562 quasars in the redshift range 2.1 ≤ z ≤ 3.5 from the data release 11 (DR11) of the Baryon Oscillation Spectroscopic Survey (BOSS) of SDSS-III. This sample contains three times the number of quasars used in previous studies. The measured position of the BAO peak determines the angular distance, D A(z = 2.34) and expansion rate, H(z = 2.34), both on a scale set by the sound horizon at the drag epoch, r d. We find D A/r d = 11.28 ± 0.65(1σ)more » $$+2.8\\atop{-1.2}$$(2σ) and D H/r d = 9.18 ± 0.28(1σ) ± 0.6(2σ) where D H = c/H. The optimal combination, ~D$$0.7\\atop{H}$$ D$0.3\\atop{A}/r d is determined with a precision of ~2%. For the value r d = 147.4 Mpc, consistent with the cosmic microwave background power spectrum measured by Planck, we find D A(z = 2.34) = 1662 ± 96(1σ) Mpc and H(z = 2.34) = 222 ± 7(1σ) km s -1 Mpc -1. Tests with mock catalogs and variations of our analysis procedure have revealed no systematic uncertainties comparable to our statistical errors. Our results agree with the previously reported BAO measurement at the same redshift using the quasar-Lyα forest cross-correlation. The autocorrelation and cross-correlation approaches are complementary because of the quite different impact of redshift-space distortion on the two measurements. The combined constraints from the two correlation functions imply values of D A/r d that are 7% lower and 7% higher for D H/r d than the predictions of a flat ΛCDM cosmological model with the best-fit Planck parameters. With our estimated statistical errors, the significance of this discrepancy is ≈2.5σ.« less
Eydoux, Cécilia; De Caro, Josiane; Ferrato, Francine; Boullanger, Paul; Lafont, Dominique; Laugier, René; Carrière, Frédéric; De Caro, Alain
2007-07-01
Recombinant human pancreatic lipase-related protein 2 (rHPLRP2) was produced in the protease A-deficient yeast Pichia pastoris. A major protein with a molecular mass of 50 kDa was purified from the culture medium using SP-Sepharose and Mono Q chromatography. The protein was found to be highly sensitive to the proteolytic cleavage of a peptide bond in the lid domain. The proteolytic cleavage process occurring in the lid affected both the lipase and phospholipase activities of rHPLRP2. The substrate specificity of the nonproteolyzed rHPLRP2 was investigated using pH-stat and monomolecular film techniques and various substrates (glycerides, phospholipids, and galactolipids). All of the enzyme activities were maximum at alkaline pH values and decreased in the pH 5-7 range corresponding to the physiological conditions occurring in the duodenum. rHPLRP2 was found to act preferentially on substrates forming small aggregates in solution (monoglycerides, egg phosphatidylcholine, and galactolipids) rather than on emulsified substrates such as triolein and diolein. The activity of rHPLRP2 on monogalactosyldiglyceride and digalactosyldiglyceride monomolecular films was determined and compared with that of guinea pig pancreatic lipase-related protein 2, which shows a large deletion in the lid domain. The presence of a full-length lid domain in rHPLRP2 makes it possible for enzyme activity to occur at higher surface pressures. The finding that the inhibition of nonproteolyzed rHPLRP2 by tetrahydrolipstatin and diethyl-p-nitrophenyl phosphate does not involve any bile salt requirements suggests that the rHPLRP2 lid adopts an open conformation in aqueous media.
Serum transferrin receptor status of healthy adult Arabs.
Knox-Macaulay, Huxley; Gravell, David; Elender, Frances
2007-01-01
Several studies have provided reference ranges for the concentration of serum transferrin receptor (sTfR) in various white populations, but there is a dearth of relevant reference sTfR data in non-whites. The aim of this investigation was to establish sTfR reference ranges and mean values for a healthy non-white Arab population that could be used also for Arabs worldwide. sTfR and serum ferritin concentrations were estimated by immunoassays and blood counts were determined by conventional methods. Analysis of the data of 114 volunteer Arab blood donors (91 male, 23 female) revealed a higher mean sTfR concentration in males of 22.6+/-8.1 nmol/L (range 10.9-38.7 nmol/L) compared to that in females of 18.7+/-4.4 nmol/L (range 10.7-25.8 nmol/L, p=0.001). There was no significant correlation of sTfR concentration with age, serum ferritin level, or blood haemoglobin level, but a strong inverse correlation was demonstrated with mean cell volume and mean cell haemoglobin of red cells. Iron-replete volunteer subjects with alpha-thalassaemia trait appear to have relatively high mean sTfR concentration. We recommend the use of gender-dependent sTfR reference values for Arabs.
Suspected hypoglycaemia in out patient practice: accuracy of dried blood spot analysis.
Parker, D R; Bargiota, A; Cowan, F J; Corrall, R J
1997-12-01
The assay of dried blood spots on filter paper to determine blood glucose concentration has been used to detect hypoglycaemia in out patients. We assessed the accuracy of this approach in assaying blood glucose concentrations in the hypoglycaemic range. Volunteers were rendered hypoglycaemic by intravenous infusion of insulin. The glucose concentration in simultaneously taken blood samples was measured either fresh or after drying on filter paper. Twenty-four healthy young volunteers and 9 patients with insulin-dependent diabetes were studied. Plasma glucose concentrations were measured using a standard auto analyser glucose oxidase method. Whole blood taken simultaneously was placed on prepared filter paper and allowed to dry; glucose concentration was then measured using a well-established technique. A correction factor was applied to convert the glucose concentration of plasma to that of whole blood. The relationship between glucose concentrations measured by the two methods was determined by regression coefficient. In the unequivocally hypoglycaemic range (plasma < or = 2.5 mmol/l), corrected dried blood spot glucose concentrations significantly correlated with standard plasma glucose concentrations (r = 0.81; P < 0.001). The dried blood spot method had a sensitivity of 91%. In the range designated probable hypoglycaemia (plasma < or = 3.3 mmol/l), there was also significant correlation (r = 0.90; P < 0.001) and the sensitivity was 96%. The specificity of the dried blood spot method was 100% in both ranges. Measurement of glucose concentrations in dried blood spots is specific and sensitive in the hypoglycaemic range. The present study indicates that hypoglycaemia may be excluded or confirmed respectively when levels in excess of 3.7 or below 2.8 mmol/l are found in uncorrected dried blood spot analysis.
Extraction of the proton radius from electron-proton scattering data
Lee, Gabriel; Arrington, John R.; Hill, Richard J.
2015-07-27
We perform a new analysis of electron-proton scattering data to determine the proton electric and magnetic radii, enforcing model-independent constraints from form factor analyticity. A wide-ranging study of possible systematic effects is performed. An improved analysis is developed that rebins data taken at identical kinematic settings and avoids a scaling assumption of systematic errors with statistical errors. Employing standard models for radiative corrections, our improved analysis of the 2010 Mainz A1 Collaboration data yields a proton electric radius r E = 0.895(20) fm and magnetic radius r M = 0.776(38) fm. A similar analysis applied to world data (excluding Mainzmore » data) implies r E = 0.916(24) fm and r M = 0.914(35) fm. The Mainz and world values of the charge radius are consistent, and a simple combination yields a value r E = 0.904(15) fm that is 4σ larger than the CREMA Collaboration muonic hydrogen determination. The Mainz and world values of the magnetic radius differ by 2.7σ, and a simple average yields r M = 0.851(26) fm. As a result, the circumstances under which published muonic hydrogen and electron scattering data could be reconciled are discussed, including a possible deficiency in the standard radiative correction model which requires further analysis.« less
Van Os, E C; McKinney, J A; Zins, B J; Mays, D C; Schriver, Z H; Sandborn, W J; Lipsky, J J
1996-04-26
A specific, sensitive, single-step solid-phase extraction and reversed-phase high-performance liquid chromatographic method for the simultaneous determination of plasma 6-mercaptopurine and azathioprine concentrations is reported. Following solid-phase extraction, analytes are separated on a C18 column with mobile phase consisting of 0.8% acetonitrile in 1 mM triethylamine, pH 3.2, run on a gradient system. Quantitation limits were 5 ng/ml and 2 ng/ml for azathioprine and 6-mercaptopurine, respectively. Peak heights correlated linearly to known extracted standards for 6-mercaptopurine and azathioprine (r = 0.999) over a range of 2-200 ng/ml. No chromatographic interferences were detected.
Soliman, Saied M; Barakat, Assem
2016-12-06
Intermolecular interactions play a vital role in crystal structures. Therefore, we conducted a topological study, using Hirshfeld surfaces and atom in molecules (AIM) analysis, to decompose and analyze, respectively, the different intermolecular interactions in six hydrazone-diacetyl platinum(II) complexes. Using AIM and natural bond orbital (NBO) analyses, we determined the type, nature, and strength of the interactions. All the studied complexes contain C-H⋯O interactions, and the presence of bond critical points along the intermolecular paths underlines their significance. The electron densities (ρ(r)) at the bond critical points (0.0031-0.0156 e/a₀³) fall within the typical range for H-bonding interactions. Also, the positive values of the Laplacian of the electron density (∇²ρ(r)) revealed the depletion of electronic charge on the interatomic path, another characteristic feature of closed-shell interactions. The ratios of the absolute potential energy density to the kinetic energy density (| V (r)|/ G (r)) and ρ(r) are highest for the O2⋯H15-N3 interaction in [Pt(COMe)₂(2-pyCMe=NNH₂)] (1); hence, this interaction has the highest covalent character of all the O⋯H intermolecular interactions. Interestingly, in [Pt(COMe)₂(H₂NN=CMe-CMe=NNH₂)] (3), there are significant N-H⋯Pt interactions. Using the NBO method, the second-order interaction energies, E (2) , of these interactions range from 3.894 to 4.061 kJ/mol. Furthermore, the hybrid Pt orbitals involved in these interactions are comprised of d xy , d xz , and s atomic orbitals.
Han, Yongtao; Song, Le; Zou, Nan; Chen, Ronghua; Qin, Yuhong; Pan, Canping
2016-09-15
A rapid and sensitive method for the determination of 171 pesticides in cowpea was developed using multi-walled carbon nanotubes (MWCNTs) as reversed-dispersive solid-phase (r-DSPE) extraction materials. The clean-up performance of MWCNTs was proved to be obviously superior to PSA and GCB. This method was validated on cowpea spiked at 0.01 and 0.1mgkg(-1) with five replicates. The mean recoveries for 169 pesticides ranged from 74% to 129% with relative standard deviations (RSDs) (n=5) lower than 16.4%, except diflufenican and quizalofop-ethyl. Good linearity for all pesticides was obtained with the calibration curve coefficients (R(2)) larger than 0.9970. The limit of detection (LODs) and limit of quantification (LOQs) for the 171 pesticides ranged from 0.001 to 0.003mgkg(-1) and from 0.002 to 0.009mgkg(-1), respectively. The method was demonstrated to be reliable and sensitive for the routine monitoring of the 171 pesticides in cowpea samples. Copyright © 2016 Elsevier B.V. All rights reserved.
Simultaneous Spectrophotometric Estimation of Nitazoxanide and Ofloxacin in Tablets
Game, Madhuri D.; Sakarkar, D. M.
2011-01-01
Two simple, accurate and precise spectrophotometric methods have been developed for simultaneous determination of nitazoxanide and ofloxacin in tablets. Method I is Q-absorbance ratio method which involves Q-absorbance at isobestic point (306.25 nm) and max (347.5 nm) of nitazoxanide, while method II is two wavelength method, where 244.6 nm and 273.0 nm were selected as 1 and 2 for determination of nitazoxanide and 294.3 nm and 388.1 nm were selected as 3 and 4 for determination of ofloxacin. Both drugs obeyed the Beer's law in the concentration range 2-30 μg/ml,correlation coefficient (r2<1). Both methods were validated statistically and recovery studies were carried out to confirm the accuracy. Commercial tablet formulation was successfully analyzed using the developed methods. PMID:22131624
NASA Astrophysics Data System (ADS)
Hellmann, Roland; Tisserand, Delphine
2006-01-01
Here we report on an experimental investigation of the relation between the dissolution rate of albite feldspar and the Gibbs free energy of reaction, Δ Gr. The experiments were carried out in a continuously stirred flow-through reactor at 150 °C and pH (150 °C) 9.2. The dissolution rates R are based on steady-state Si and Al concentrations and sample mass loss. The overall relation between Δ Gr and R was determined over a free energy range of -150 < Δ Gr < -15.6 kJ mol -1. The data define a continuous and highly non-linear, sigmoidal relation between R and Δ Gr that is characterized by three distinct free energy regions. The region furthest from equilibrium, delimited by -150 < Δ Gr < -70 kJ mol -1, represents an extensive dissolution rate plateau with an average rate R¯=1.0×10-8molm-2s-1. In this free energy range the rates of dissolution are constant and independent of Δ Gr, as well as [Si] and [Al]. The free energy range delimited by -70 ⩽ Δ Gr ⩽ -25 kJ mol -1, referred to as the 'transition equilibrium' region, is characterized by a sharp decrease in dissolution rates with increasing Δ Gr, indicating a very strong inverse dependence of the rates on free energy. Dissolution nearest equilibrium, defined by Δ Gr > -25 kJ mol -1, represents the 'near equilibrium' region where the rates decrease as chemical equilibrium is approached, but with a much weaker dependence on Δ Gr. The lowest rate measured in this study, R = 6.2 × 10 -11 mol m -2 s -1 at Δ Gr = -16.3 kJ mol -1, is more than two orders of magnitude slower than the plateau rate. The data have been fitted to a rate equation (adapted from Burch et al. [Burch, T. E., Nagy, K. L., Lasaga, A. C., 1993. Free energy dependence of albite dissolution kinetics at 80 °C and pH 8.8. Chem. Geol.105, 137-162]) that represents the sum of two parallel reactions R=k1[1-exp(-ng)]+k2[1-exp(-g)], where k1 and k2 are rate constants that have been determined by regression, with values 1.02 × 10 -8 and 1.80 × 10 -10 mol m -2 s -1, g ≡ |Δ Gr|/R T is a dimensionless number, and n, m1, and m2 are adjustable fitted parameters ( n = 7.98 × 10 -5, m1 = 3.81 and m2 = 1.17). Based on measurements of the temporal evolution of RSi and RAl for each experiment, steady-state dissolution rates appear to be congruent at all Δ Gr. In contrast, non-steady-state dissolution is incongruent, and is related to Δ Gr. Scanning electron microscopy (SEM) images of post-reaction grain surfaces indicate that dissolution close to equilibrium (Δ Gr > -25 kJ mol -1) resulted in the precipitation of a secondary crystalline phase, but there are no indications that this altered the measured R-Δ Gr relation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kropp, J.; Reske, S.N.; Biersack, H.J.
Stimulated Renin-Angiotensin System (RAS) in aortic insufficiency (AI) leads to increased afterload and consequently to augmented aortic regurgitation (R). Therefore Captopril (C) mediated RAS-inhibition should diminish systemic vascular resistance and thus reduce R. In 9 patients (pts) with pure severe AI regurgitation fraction (RF) and left ventricular ejection fraction (LVEF) were determined before and 1 hr after i.v. injection of 25 mg C by gated radionuclide ventriculographie (RNV), using red blood cells labeled in vivo with 15 mCi Tc-99m. Enddiastolic and endsystolid frames were derived from the left ventricular volume curve. ROI's were selected over both ventricles. Ventricular boundaries weremore » defined by a fourier phase image overlay. RF was calculated by the background corrected count rate ratio of left and right ventricular ROI. Arterial blood pressure (BP), heart rate (HR), plasma levels of angiotensin I, II (A1,A2), and the activity of angiotensin converting enzyme (ACE) were determined before and 1 hr after C-injection. Before C-medication mean RF was 54% (range 34% - 67%), after C mean RF decreased to 37% (17% - 59% range, rho<.05). Mean LVEF increased not significantly from 60% (range 51%-70%) to 66% (range 56% - 77%, rho>0.55). C did not significantly change HR or BP (HR: rho>0.9, BP: rho>0.6). A2 and ACE activity decreased to 40% and 50% of control values (rho<.01), respectively. A1 increased excessively. The authors conclude that the inhibition of ACE reduces significantly aortic regurgitation in patients with A1 and has thus a beneficial effect on left ventricular performance.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Magee, J.W.
1998-09-01
The p-{rho}-T relationships have been measured for 1,1-difluoroethane (R152a) and 1,1,1-trifluoroethane (R143a) by an isochoric method with gravimetric determinations of the amount of substance. Temperatures ranged from 158 to 400K for R152a and from 166 to 400 K for R143a, while pressures were up to 35 MPa. Measurements were conducted on compressed liquid samples. Determinations of saturated liquid densities were made by extrapolating each isochore to the vapor pressure, and determining the temperature and density at the intersection. Published p-{rho}-T data are in good agreement with this study. For the p-{rho}-T apparatus, the uncertainty of the temperature is {+-}0.03 K,more » and for pressure it is {+-}0.01% at p > 3 MPa and {+-}0.05% at p > 3 MPa and {+-}0.05% at p < 3MPa. The principal source of uncertainty is the cell volume ({approximately}28.5 cm{sup 3}), which has a standard uncertainty of {+-}0.003 cm{sup 3}. When all components of experimental uncertainty are considered, the expanded relative uncertainty (with a coverage factor k = 2 and thus a two-standard deviation estimate) of the density measurement is estimated to be {+-}0.05%.« less
Lampen, P; Neumeyer, J L; Baldessarini, R J
1988-04-29
The dopamine receptor agonist R(-)N-n-propylnorapomorphine (NPA) and its proposed pro-drug R(-)10,11-methylenedioxy-N-n-propylnoraporphine (MDO-NPA) were isolated simultaneously from monkey plasma using a solid-phase extraction procedure. R(-)Apomorphine (APO) and R(-)10,11-methylenedioxyaporphine (MDO-APO) were added as internal standards, and separation and quantification were by high-performance liquid chromatography with electrochemical or ultraviolet detection of the free catechol and MDO compounds, respectively. The detection limits for NPA and MDO-NPA in plasma were 0.5 and 10 ng/ml and the coefficient of variation (S.D./mean) within assays and between days of assays for both drugs was 5.6% or less. Quantification of plasma levels of NPA and MDO-NPA was possible at ranges of 2-1000 and 40-5000 ng/ml, respectively, including concentrations found after intravenous administration of these agents.
Predictors of activity limitation in people with gout: a prospective study.
Stewart, Sarah; Rome, Keith; Eason, Alastair; House, Meaghan E; Horne, Anne; Doyle, Anthony J; Knight, Julie; Taylor, William J; Dalbeth, Nicola
2018-04-21
The objective of the study was to determine clinical factors associated with activity limitation and predictors of a change in activity limitation after 1 year in people with gout. Two hundred ninety-five participants with gout (disease duration < 10 years) attended a baseline assessment which included medical and disease-specific history, pain visual analog score and plain radiographs scored for erosion and narrowing. Activity limitation was assessed using the Health Assessment Questionnaire-II (HAQ-II). After 1 year, participants were invited to complete a further HAQ-II; follow-up questionnaires were available for 182 participants. Fully saturated and stepwise regression analyses were used to determine associations between baseline characteristics and HAQ-II at baseline and 1 year, and to determine predictors of worsening HAQ-II in those with normal baseline scores. Median (range) baseline HAQ-II was 0.20 (0-2.50) and 0.20 (0-2.80) after 1 year of follow-up. Pain score was the strongest independent predictor of baseline HAQ-II, followed by radiographic narrowing score, type 2 diabetes, swollen joint count, BMI, age and urate (model R 2 = 0.51, P < 0.001). Baseline HAQ-II was the strongest predictor of change in HAQ-II at 1 year, followed by tender joint count (model R 2 = 0.19, P < 0.001). Of those with HAQ-II scores of 0 at baseline (n = 59, 32% of those with follow-up data), most did not progress (n = 52, 88%); however, baseline pain score, type 2 diabetes and flare frequency were significant predictors of worsening HAQ-II in this group (R 2 = 0.34, P < 0.001). People with gout experience a wide range of activity limitation, and levels of activity limitation are, on average, stable over a 1-year period. Baseline pain scores are strongly associated with activity limitation and predict development of activity limitation in those with normal HAQ-II scores at baseline.
Pisegna, Jessica M; Kaneoka, Asako; Leonard, Rebecca; Langmore, Susan E
2018-02-01
The goal of this work was to better understand perceptual judgments of pharyngeal residue on flexible endoscopic evaluation of swallowing (FEES) and the influence of a visual analog scale (VAS) versus an ordinal scale on clinician ratings. The intent was to determine if perceptual judgments of residue were more accurately described by equal or unequal intervals. Thirty-three speech language pathologists rated pharyngeal residue from 75 FEES videos representing a wide range of residue severities for thin liquid, applesauce, and cracker boluses. Clinicians rated their impression of the overall residue amount in each video on a VAS and, in a different session, on a five-point ordinal scale. Residue ratings were made in two separate sessions separated by several weeks. Statistical correlations of the two rating methods were carried out and best-fit models were determined for each bolus type. A total of 2475 VAS ratings and 2473 ordinal ratings were collected. Residue ratings from both methods (VAS and ordinal) were strongly correlated for all bolus types. The best fit for the data was a quadratic model representing unequal intervals, which significantly improved the r 2 values for each bolus type (cracker r 2 = 0.98, applesauce r 2 = 0.99, thin liquid r 2 = 0.98, all p < 0.0001). Perceptual ratings of pharyngeal residue demonstrated a statistical relationship consistent with unequal intervals. The present findings support the use of a VAS to rate residue on FEES, allowing for greater precision as compared to traditional ordinal rating scales. Perceptual judgments of pharyngeal residue reflected unequal intervals, an important concept that should be considered in future rating scales.
Solbeck, Sacha; Jensen, Annette Schophuus; Maschmann, Christian; Stensballe, Jakob; Ostrowski, Sisse Rye; Johansson, Pär I
Monitoring the effect of dabigatran (Pradaxa ® ) is challenging. The aim of this study was to evaluate if thrombelastography reaction time (TEG ® R) could detect the anticoagulant effect of dabigatran showing a correlation between TEG ® R, Hemoclot Thrombin Inhibitor (HTI) assay and Ecarin Clotting Time (ECT) in patients with non-valvular atrial fibrillation (NVAF). Blood samples from 35 AF patients receiving either 110 mg (n 19) or 150 mg (n 16) dabigatran twice daily were analyzed with TEG ® , HTI and ECT 2-3 h after dabigatran intake. All patients had prolonged TEG ® R. The patients receiving dabigatran 110 mg ×2 had a TEG ® R mean 14.2 min (range 9.1-25), a mean dabigatran concentration measured by HTI of 268.5 ng/mL (range 54-837 ng/mL) and by ECT of 355.7 ng/mL (range 40-1020 ng/mL). The corresponding numbers for patients receiving dabigatran 150 mg ×2 were TEG ® R mean of 12.5 min (range 9.2-23.2 min), mean dabigatran concentration of 179.2 ng/mL by HTI (range 26-687 ng/mL) and by ECT 225.1 ng/mL (range 42-1020 ng/mL). The two dosage groups had comparable anticoagulation demonstrated by equally prolonged TEG ® R (p = .909), HTI (p = .707) and ECT (p = .567). No difference in creatinine levels in the two dosage groups was observed (p = .204) though patients with dabigatran concentration >400 ng/mL had significantly higher creatinine levels (p = .001). Large individual variation of the anticoagulant response was observed. Some patients had TEG ® R values up to three times upper normal limit with immediate risk of bleeding. Our data indicate that TEG ® R reflected dabigatran levels in NVAF patients and that TEG ® R correlated to HTI and ECT.
NASA Astrophysics Data System (ADS)
Karimi-Maleh, Hassan; Bananezhad, Asma; Ganjali, Mohammad R.; Norouzi, Parviz; Sadrnia, Abdolhossein
2018-05-01
Didanosine is nucleoside analog reverse transcriptase inhibitors with many side effects such as nausea and vomiting, stomach pain, tingling, burning and numbness and determination of this drug is very important in biological samples. This paper presents a DNA biosensor for determination of didanosine (DDI) in pharmaceutical samples. A pencil graphite electrode modified with conductive materials such as polypyrrole (PPy) and reduced graphene oxide (rGO) (PGE/PPy/rGO) was used for this goal. The double-stranded DNA was successfully immobilized on PGE/PPy/rGO. The PGE/PPy/rGO was characterized by microscopic and electrochemical methods. Then, the interaction of DDI with DNA was identified by decreases in the oxidation currents of guanine and adenine by differential pulse voltammetric (DPV) method. The dynamic range of DDI identified in the range of 0.02-50.0 μM and this electrode provided a low limit of detection (LOD = 8.0 nM) for DDI. The PGE/PPy/rGO loaded with ds-DNA was utilized for the measurement of DDI in real samples and obtained data were compared with HPLC method. The statistical tests such as F-test and t-test were used for confirming ability of PGE/PPy/rGO loaded with ds-DNA for analysis of DDI in real samples.
3D-HST+CANDELS: The Evolution of the Galaxy Size-Mass Distribution since z = 3
NASA Astrophysics Data System (ADS)
van der Wel, A.; Franx, M.; van Dokkum, P. G.; Skelton, R. E.; Momcheva, I. G.; Whitaker, K. E.; Brammer, G. B.; Bell, E. F.; Rix, H.-W.; Wuyts, S.; Ferguson, H. C.; Holden, B. P.; Barro, G.; Koekemoer, A. M.; Chang, Yu-Yen; McGrath, E. J.; Häussler, B.; Dekel, A.; Behroozi, P.; Fumagalli, M.; Leja, J.; Lundgren, B. F.; Maseda, M. V.; Nelson, E. J.; Wake, D. A.; Patel, S. G.; Labbé, I.; Faber, S. M.; Grogin, N. A.; Kocevski, D. D.
2014-06-01
Spectroscopic+photometric redshifts, stellar mass estimates, and rest-frame colors from the 3D-HST survey are combined with structural parameter measurements from CANDELS imaging to determine the galaxy size-mass distribution over the redshift range 0 < z < 3. Separating early- and late-type galaxies on the basis of star-formation activity, we confirm that early-type galaxies are on average smaller than late-type galaxies at all redshifts, and we find a significantly different rate of average size evolution at fixed galaxy mass, with fast evolution for the early-type population, R effvprop(1 + z)-1.48, and moderate evolution for the late-type population, R effvprop(1 + z)-0.75. The large sample size and dynamic range in both galaxy mass and redshift, in combination with the high fidelity of our measurements due to the extensive use of spectroscopic data, not only fortify previous results but also enable us to probe beyond simple average galaxy size measurements. At all redshifts the slope of the size-mass relation is shallow, R_{eff}\\propto M_*^{0.22}, for late-type galaxies with stellar mass >3 × 109 M ⊙, and steep, R_{eff}\\propto M_*^{0.75}, for early-type galaxies with stellar mass >2 × 1010 M ⊙. The intrinsic scatter is lsim0.2 dex for all galaxy types and redshifts. For late-type galaxies, the logarithmic size distribution is not symmetric but is skewed toward small sizes: at all redshifts and masses, a tail of small late-type galaxies exists that overlaps in size with the early-type galaxy population. The number density of massive (~1011 M ⊙), compact (R eff < 2 kpc) early-type galaxies increases from z = 3 to z = 1.5-2 and then strongly decreases at later cosmic times.
A reduced graphene oxide based electrochemical biosensor for tyrosine detection
NASA Astrophysics Data System (ADS)
Wei, Junhua; Qiu, Jingjing; Li, Li; Ren, Liqiang; Zhang, Xianwen; Chaudhuri, Jharna; Wang, Shiren
2012-08-01
In this paper, a ‘green’ and safe hydrothermal method has been used to reduce graphene oxide and produce hemin modified graphene nanosheet (HGN) based electrochemical biosensors for the determination of l-tyrosine levels. The as-fabricated HGN biosensors were characterized by UV-visible absorption spectra, fluorescence spectra, Fourier transform infrared spectroscopy (FTIR) spectra and thermogravimetric analysis (TGA). The experimental results indicated that hemin was successfully immobilized on the reduced graphene oxide nanosheet (rGO) through π-π interaction. TEM images and EDX results further confirmed the attachment of hemin on the rGO nanosheet. Cyclic voltammetry tests were carried out for the bare glass carbon electrode (GCE), the rGO electrode (rGO/GCE), and the hemin-rGO electrode (HGN/GCE). The HGN/GCE based biosensor exhibits a tyrosine detection linear range from 5 × 10-7 M to 2 × 10-5 M with a detection limitation of 7.5 × 10-8 M at a signal-to-noise ratio of 3. The sensitivity of this biosensor is 133 times higher than that of the bare GCE. In comparison with other works, electroactive biosensors are easily fabricated, easily controlled and cost-effective. Moreover, the hemin-rGO based biosensors demonstrate higher stability, a broader detection linear range and better detection sensitivity. Study of the oxidation scheme reveals that the rGO enhances the electron transfer between the electrode and the hemin, and the existence of hemin groups effectively electrocatalyzes the oxidation of tyrosine. This study contributes to a widespread clinical application of nanomaterial based biosensor devices with a broader detection linear range, improved stability, enhanced sensitivity and reduced costs.
A reduced graphene oxide based electrochemical biosensor for tyrosine detection.
Wei, Junhua; Qiu, Jingjing; Li, Li; Ren, Liqiang; Zhang, Xianwen; Chaudhuri, Jharna; Wang, Shiren
2012-08-24
In this paper, a 'green' and safe hydrothermal method has been used to reduce graphene oxide and produce hemin modified graphene nanosheet (HGN) based electrochemical biosensors for the determination of l-tyrosine levels. The as-fabricated HGN biosensors were characterized by UV-visible absorption spectra, fluorescence spectra, Fourier transform infrared spectroscopy (FTIR) spectra and thermogravimetric analysis (TGA). The experimental results indicated that hemin was successfully immobilized on the reduced graphene oxide nanosheet (rGO) through π-π interaction. TEM images and EDX results further confirmed the attachment of hemin on the rGO nanosheet. Cyclic voltammetry tests were carried out for the bare glass carbon electrode (GCE), the rGO electrode (rGO/GCE), and the hemin-rGO electrode (HGN/GCE). The HGN/GCE based biosensor exhibits a tyrosine detection linear range from 5 × 10(-7) M to 2 × 10(-5) M with a detection limitation of 7.5 × 10(-8) M at a signal-to-noise ratio of 3. The sensitivity of this biosensor is 133 times higher than that of the bare GCE. In comparison with other works, electroactive biosensors are easily fabricated, easily controlled and cost-effective. Moreover, the hemin-rGO based biosensors demonstrate higher stability, a broader detection linear range and better detection sensitivity. Study of the oxidation scheme reveals that the rGO enhances the electron transfer between the electrode and the hemin, and the existence of hemin groups effectively electrocatalyzes the oxidation of tyrosine. This study contributes to a widespread clinical application of nanomaterial based biosensor devices with a broader detection linear range, improved stability, enhanced sensitivity and reduced costs.
Xu, Xiaomin; He, Huali; Ruan, Yudi; Huang, Baifen; Zhang, Jingshun; Cai, Zengxuan; Ren, Yiping
2013-11-01
A simultaneous determination method for ethyl carbamate (EC) and chloropropanols (3-monochloropropane-1, 2-diol (3-MCPD) and 2-monochloropropane-1, 3-diol (2-MCPD)) in flavorings was developed by gas chromatography-triple quadrupole tandem mass spectrometry (GC-MS/MS). After spiked with internal standard, the sample was extracted by matrix solid-phase dispersion extraction technique with an Extrelut NT column. Hexane was used to wash the fat soluble matrix interferences and then an ethyl acetate-ethyl ether (20: 80, v/v) mixture was added to elute the analytes. The concentrated extract was detected by GC-MS/MS in multiple reaction monitoring (MRM) mode. The limits of detection (LODs) were 2, 5 and 5 microg/kg for EC, 3-MCPD and 2-MCPD, respectively. The linear ranges were 5 - 1 000 microg/kg (r = 0.9997), 10-1000 microg/kg (r = 0.999 1) and 10-1000 microg/kg (r = 0.999 5) for EC, 3-MCPD and 2-MCPD, respectively. In soy sauce, yellow rice wine, salami sauce and flavoring of instant noodle matrices, the recoveries (RSDs, n = 7) in MRM mode at the levels of 20, 100 and 400 microg/kg were 87.7%-104% (4.3%-10.7%), 90.1%-109% (2.6%-10.2%), and 90.9%-103% (3.0%-9.5%), respectively. EC, 3-MCPD and 2-MCPD were found in some real samples of the soy sauce, wine and flavoring of instant noodle. EC or 3-MCPD was found in some of the salami samples. The method is accurate, fast and suitable for the simultaneous determination of EC, 3-MCPD and 2-MCPD in flavorings.
Tamburini, Elena; Tagliati, Chiara; Bonato, Tiziano; Costa, Stefania; Scapoli, Chiara; Pedrini, Paola
2016-01-01
Near-infrared spectroscopy (NIRS) has been widely used for quantitative and/or qualitative determination of a wide range of matrices. The objective of this study was to develop a NIRS method for the quantitative determination of fluorine content in polylactide (PLA)-talc blends. A blending profile was obtained by mixing different amounts of PLA granules and talc powder. The calibration model was built correlating wet chemical data (alkali digestion method) and NIR spectra. Using FT (Fourier Transform)-NIR technique, a Partial Least Squares (PLS) regression model was set-up, in a concentration interval of 0 ppm of pure PLA to 800 ppm of pure talc. Fluorine content prediction (R2cal = 0.9498; standard error of calibration, SEC = 34.77; standard error of cross-validation, SECV = 46.94) was then externally validated by means of a further 15 independent samples (R2EX.V = 0.8955; root mean standard error of prediction, RMSEP = 61.08). A positive relationship between an inorganic component as fluorine and NIR signal has been evidenced, and used to obtain quantitative analytical information from the spectra. PMID:27490548
Persistence length changes dramatically as RNA folds.
Caliskan, G; Hyeon, C; Perez-Salas, U; Briber, R M; Woodson, S A; Thirumalai, D
2005-12-31
We determine the persistence length l(p) for a bacterial group I ribozyme as a function of concentration of monovalent and divalent cations by fitting the distance distribution functions P(r) obtained from small angle x-ray scattering intensity data to the asymptotic form of the calculated P(WLC)(r) for a wormlike chain. The l(p) values change dramatically over a narrow range of Mg(2+) concentration from approximately 21 Angstroms in the unfolded state (U) to approximately 10 Angstroms in the compact (I(C)) and native states. Variations in l(p) with increasing Na(+) concentration are more gradual. In accord with the predictions of polyelectrolyte theory we find l(p) alpha 1/kappa(2) where kappa is the inverse Debye-screening length.
Horrevorts, Esther M B; van Grieken, Amy; Mieloo, Cathelijne L; Hafkamp-de Groen, Esther; Bannink, Rienke; Bouwmeester-Landweer, Merian B R; Broeren, Suzanne; Raat, Hein
2017-01-01
Objectives To determine the feasibility, concurrent validity and discriminatory power of the instrument for Identification of Parents At Risk for child Abuse and Neglect (IPARAN) among Dutch parents with a newborn child. Setting Community paediatrics. Participants Data from a controlled trial were used. In total, 2659 Dutch parents with a newborn child were invited to participate. Of the 2659 parents, 759 parents filled in the consent form and participated in the study. Primary and secondary outcome measures Concurrent validity was determined by calculating correlations—using the Pearson’s correlation (r)—between the IPARAN score and related constructs from the following instruments: the Empowerment Questionnaire 2.0, the Family Functioning Questionnaire and the Parenting Stress Questionnaire. Discriminatory power was determined by calculating receiver operating characteristic (ROC) curves between high-risk mothers and low-risk mothers according to their scores on the related constructs. Feasibility was determined by examining the percentage of missing answers. Results In terms of concurrent validity, we found that 3 out of 12 correlations between the IPARAN score and related constructs were strong (ie, r>0.50) and 4 out of 12 were medium (ie, r=0.30–0.49). In terms of discriminatory power, mothers with a score in the borderline/clinical range or lowest 10 percent (P10) range of the related constructs (high-risk mothers) had a higher IPARAN score than mothers with a score in the normal range or highest 90 percent (P90) range of the related constructs (low-risk mothers). Effect sizes varied from d=0.37 to d=1.93, and the area under the ROC curve varied from 0.62 to 0.93. Regarding feasibility, the part of the IPARAN filled in by the mother had on average 0.7% missing answers, whereas the part of the IPARAN filled in by the father had on average 1.7% missing answers. Conclusion The results of this study support the concurrent validity, discriminatory power and feasibility of the IPARAN among a population of Dutch parents with a newborn child. PMID:28838892
Thomas, Lothar; Franck, Susanne; Messinger, Maren; Linssen, Jo; Thomé, Marcus; Thomas, Christian
2005-01-01
The aims of this study were to diagnose iron-restricted erythropoiesis (functional iron deficiency) in patients with classic iron deficiency (ID), anemia of chronic disease (ACD) and the combined state of ID/ACD with the use of two hematological methods for the measurement of reticulocyte hemoglobinization. In comparison, the biochemical markers of iron status were determined. We studied 474 anemic patients admitted to hospital with a broad spectrum of diseases. We measured indicators of reticulocyte hemoglobinization. CHr was determined on an Advia 120 hematology analyzer. A Sysmex XE-2100 hematology analyzer was used to determine RET-Y, the forward scatter of fluorescence-labeled reticulocytes, which can also be expressed as the reticulocyte hemoglobin equivalent (RET-H(e)), as well as RBC-Y, the forward scatter of fluorescence-labeled erythrocytes, which can be expressed as the erythrocyte hemoglobin equivalent. Ferritin, soluble transferrin receptor (sTfR) and the sTfR/log ferritin ratio (sTfR-F index) were used as biochemical markers. The comparison of RET-Y with CHr demonstrated an excellent curvilinear relationship between the two parameters. The normal reference range for Ret-Y was 1630-1860 arbitrary units (AU); mathematical transformation to RET-H(e) gave a range of 28.2-35.7 pg. Correlations of biochemical iron markers with RET-H(e) were as weak as with CHr in patients with ACD and acute phase response. In a diagnostic plot to identify iron status, RET-H(e) could replace CHr without any loss of sensitivity or specificity. Patient mismatch analysis between RET-H(e) and CHr in the diagnostic plot demonstrated agreement for 449 of 474 patients (94.4%). Patient specific anemia mismatches were 2.9-6.2%. According to our results, the indicators of reticulocyte hemoglobinization, RET-H(e) and CHr, measure the same phenomenon. RET-H(e) is as valuable as CHr for the diagnosis of iron-restricted erythropoiesis. The combination of RET-H(e) and the sTfR-F index in a diagnostic plot offers an attractive tool for the evaluation of iron status and identification of the progression of ID.
NASA Astrophysics Data System (ADS)
Pragourpun, Kraivinee; Sakee, Uthai; Fernandez, Carlos; Kruanetr, Senee
2015-05-01
We present for the first time the use of deferiprone as a non-toxic complexing agent for the determination of iron by sequential injection analysis in pharmaceuticals and food samples. The method was based on the reaction of Fe(III) and deferiprone in phosphate buffer at pH 7.5 to give a Fe(III)-deferiprone complex, which showed a maximum absorption at 460 nm. Under the optimum conditions, the linearity range for iron determination was found over the range of 0.05-3.0 μg mL-1 with a correlation coefficient (r2) of 0.9993. The limit of detection and limit of quantitation were 0.032 μg mL-1 and 0.055 μg mL-1, respectively. The relative standard deviation (%RSD) of the method was less than 5.0% (n = 11), and the percentage recovery was found in the range of 96.0-104.0%. The proposed method was satisfactorily applied for the determination of Fe(III) in pharmaceuticals, water and food samples with a sampling rate of 60 h-1.
Regression Analysis of Stage Variability for West-Central Florida Lakes
Sacks, Laura A.; Ellison, Donald L.; Swancar, Amy
2008-01-01
The variability in a lake's stage depends upon many factors, including surface-water flows, meteorological conditions, and hydrogeologic characteristics near the lake. An understanding of the factors controlling lake-stage variability for a population of lakes may be helpful to water managers who set regulatory levels for lakes. The goal of this study is to determine whether lake-stage variability can be predicted using multiple linear regression and readily available lake and basin characteristics defined for each lake. Regressions were evaluated for a recent 10-year period (1996-2005) and for a historical 10-year period (1954-63). Ground-water pumping is considered to have affected stage at many of the 98 lakes included in the recent period analysis, and not to have affected stage at the 20 lakes included in the historical period analysis. For the recent period, regression models had coefficients of determination (R2) values ranging from 0.60 to 0.74, and up to five explanatory variables. Standard errors ranged from 21 to 37 percent of the average stage variability. Net leakage was the most important explanatory variable in regressions describing the full range and low range in stage variability for the recent period. The most important explanatory variable in the model predicting the high range in stage variability was the height over median lake stage at which surface-water outflow would occur. Other explanatory variables in final regression models for the recent period included the range in annual rainfall for the period and several variables related to local and regional hydrogeology: (1) ground-water pumping within 1 mile of each lake, (2) the amount of ground-water inflow (by category), (3) the head gradient between the lake and the Upper Floridan aquifer, and (4) the thickness of the intermediate confining unit. Many of the variables in final regression models are related to hydrogeologic characteristics, underscoring the importance of ground-water exchange in controlling the stage of karst lakes in Florida. Regression equations were used to predict lake-stage variability for the recent period for 12 additional lakes, and the median difference between predicted and observed values ranged from 11 to 23 percent. Coefficients of determination for the historical period were considerably lower (maximum R2 of 0.28) than for the recent period. Reasons for these low R2 values are probably related to the small number of lakes (20) with stage data for an equivalent time period that were unaffected by ground-water pumping, the similarity of many of the lake types (large surface-water drainage lakes), and the greater uncertainty in defining historical basin characteristics. The lack of lake-stage data unaffected by ground-water pumping and the poor regression results obtained for that group of lakes limit the ability to predict natural lake-stage variability using this method in west-central Florida.
Lippincott, Margaret F; Carlow, Andrea; Desai, Aditi; Blum, Arnon; Rodrigo, Maria; Patibandla, Sushmitha; Zalos, Gloria; Smith, Kevin; Schenke, William H; Csako, Gyorgy; Waclawiw, Myron A; Cannon, Richard O
2008-08-01
Our purpose was to determine predictors of endothelial function and potential association with cardiovascular risk in women with sedentary occupations, in whom obesity-associated risk factors may contribute to excess morbidity and mortality. Ninety consecutive women (age range 22 to 63 years, 22 overweight (body mass index [BMI] > or =25 to 29.9 kg/m(2)) and 42 obese (BMI > or = 30 kg/m(2)), had vital signs, lipids, insulin, glucose, high-sensitivity C-reactive protein, and sex hormones measured. Endothelial function was determined using brachial artery flow-mediated dilation after 5 minutes of forearm ischemia. Treadmill stress testing was performed with gas exchange analysis at peak exercise (peak oxygen consumption [Vo(2)]) to assess cardiorespiratory fitness. Brachial artery reactivity was negatively associated with Framingham risk score (r = -0.3542, p = 0.0007). Univariate predictors of endothelial function included peak Vo(2) (r = 0.4483, p <0.0001), age (r = -0.3420, p = 0.0010), BMI (r = -0.3065, p = 0.0035), and high-sensitivity C-reactive protein (r = -0.2220, p = 0.0400). Using multiple linear regression analysis with stepwise modeling, peak Vo(2) (p = 0.0003) was the best independent predictor of brachial artery reactivity, with age as the only other variable reaching statistical significance (p = 0.0436) in this model. In conclusion, endothelial function was significantly associated with cardiovascular risk in women with sedentary occupations, who were commonly overweight or obese. Even in the absence of routine exercise, cardiorespiratory fitness, rather than conventional risk factors or body mass, is the dominant predictor of endothelial function and suggests a modifiable approach to risk.
Multi-Stage Maximum Likelihood Target Estimator
2006-03-31
Compute the range at ti with respect to 19 the sensor associated with the ith 20 measurement (Ri): 23 1 R, = VRx ’+ Ryl’ (3 2 2.) Compute the range...the ith measurement 12 ii. Compute the range at tj with respect tothe 13 sensor associated with the ith measurement (R4) 14 = VRx + Ry (323) 15 iii
Comparative Analysis of Red-Edge Hyperspectral Indices
NASA Astrophysics Data System (ADS)
Gupta, R.; Vijayan, D.; Prasad, T.
The spectrally continuous observations of 3 nm bandwidth in 680 to 800 nm range over the growth cycle of wheat were subjected to first order differentiation to identify the point of inflection in red to near-IR transition zone. During 40 to 84 days after sowing (DAS), the point of inflection was observed in 723 to 735 nm region with peak response at 729 nm for 64 DAS . For differentiated curve pertaining to 25 DAS (initial vegetative) and 90 DAS (initial senescence) phenological stages, the point of inflection was in 690-693 and 744-747 nm spectral region, respectively. The ratios corresponding to 1dB (RI1dB = R 735 /R720), 2dB (RI 2dB = R738/R 720), 3dB (RI3dB = R741 /R 717) down signal levels and half signal level (RIhalf = R747/R 708 ) were computed. For nomenclature point of view, R41 refers to reflectance for 3 nm7 bandwidth centered at 741 nm. Correlations for these developed RIs were studied with reference to indices given by Vogelmann i.e., VOG a = R 740 /R720 , VOG b = [(R 734-R747)/(R715+R720)] and red edge spectral parameter (RESP) = R750 /R 710. VOG a and RESP conceptually resemble with developed RI 2dB and RIhalf , respectively. All RIs were found correlated with VOGa , VOG b and RESP with r2 in the range of 0.96 to 0.99; r2 was 0.998 for RI2dB and VOG a pair and 0.996 for RI half and RESP pair; the slope factor of regression relationship improved by about 50% from RI dB to2 RI3dB and by about 125% from RI3dB to RIhalf with r2 in 0.97-0.99 range. Thus, theoretical basis for VOG a and RESP in terms of dB based indices has been provided. The wavelengths used in VOGb are noticed in dB based indices ; to provide stability to small magnitude R720, the sum of R720 and R715 has been used in VOGb. Based on regression analysis of these indices with LAI in its growth and decline phases separately, the slope value for VOG b, RI 2dB, VOG a, RIhalf, RESP and area under 680 to 760 nm for first order derivative curve (area) were in 0.08-0.11, 0.24 - 0.34, 0.27-0.38, 0.86-1.18, 0.89-1.27 and 7.6-13.87 range, respectively. Here, the first value in the range refers to slope value for the growth phase of LAI while the second value in the range refers to that for the decline phase of LAI. To judge the sensitivity for the rate of change in red - edge, the change in area for ratio indices and normalized indices in 680 to 760 nm (red-near IR transition region) with 673 nm were analysed. The rate of change for area under the red edge as a function of DAS was more for ratio indices as compared to that for normalized indices.
[Mutual Effect on Determination of Gibberellins and Glyphosate in Groundwater by Spectrophotometry].
Zhang, Li; Chen, Liang; Liu, Fei
2015-04-01
In the present study, a spectrophotometry method for the simultaneous determination of gibberellins (GA3) and glyphosate in groundwater was established and optimized. In addition, the mutual effect on simultaneous determination of GA3 and glyphosate was studied. Based on the experiment, good linearity (R2 > 0.99) was obtained for GA3 in the range of 0-20 and 0-100 µg and for glyphosate in the range of 0-8 and 5-15 µg. The method's detection limit (MDL) of GA3 and glyphosate was 0.48 and 0.82 µg, respectively; and the recovery rates of 15 to 150 µg GA3 and 3 to 10 µg glyphosate in all samples at a spiked level were 71.3% ± 1.9% and 98.4% ± 8.1%, respectively. No obvious influence of glyphosate (0-100 mg · L(-1)) on the recovery rates of GA3 was observed, but the presence of glyphosate could cause slight determination precision decrease of GA3. Meanwhile, adding 2 mg · L(-1) GA3 can increase the recovery rate of glyphosate.
The human foramen magnum--normal anatomy of the cisterna magna in adults.
Whitney, Nathaniel; Sun, Hai; Pollock, Jeffrey M; Ross, Donald A
2013-11-01
The goal of this study was to radiologically describe the anatomical characteristics of the cisterna magna (CM) with regard to presence, dimension, and configuration. In this retrospective study, 523 records were reviewed. We defined five CM types, the range of which covered all normal variants found in the study population. Characteristics of the CM were recorded and correlations between various posterior fossa dimensions and CM volume determined. There were 268 female (mean age 50.9 ± 16.9 years) and 255 male (mean age 54.1 ± 15.8 years) patients. CM volume was smaller in females than in males and correlated with age (Pearson correlation, r = 0.1494, p = 0.0006) and gender (unpaired t test, r (2) = 0.0608, p < 0.0001). Clivus length correlated with CM volume (Pearson correlation, r = 0.211, p < 0.0001) and gender (unpaired t test, r (2) = 0.2428, p < 0.0001). Tentorial angle did not correlate with CM volume (Pearson correlation, r = -0.0609, p < 0.1642) but did correlate with gender (unpaired t test, r (2) = 0.0163, p < 0.0035). The anterior-posterior dimension of cerebrospinal fluid anterior to the brainstem correlated with CM volume (Pearson correlation, r = 0.181, p < 0.0001) and gender (unpaired t test, r (2) = 0.0205, p = 0.001). The anatomical description and simple classification system we define allows for a more precise description of posterior fossa anatomy and could potentially contribute to the understanding of Chiari malformation anatomy and management.
Characterization of nitrogen and water status in oat leaves using optical sensing approach.
Zhao, Baoping; Ma, Bao-Luo; Hu, Yuegao; Liu, Jinghui
2015-01-01
Optical sensing is a potential tool to estimate plant N status, but soil water deficits may interefere with forming a clear relationship. A greenhouse study was conducted with oat plants treated with three water regimes and four N levels to determine whether optical sensing could be used to estimate leaf N and relative water content (RWC). Leaf N was strongly correlated with reflectance at 550 nm and at around 705 nm, and N treatments caused a red-edge peak shift to lower wavelength. The ratio of the first derivative reflectance at 741-696 nm (FDRE) was identified to be a good estimator of leaf N at jointing (R(2) = 0.90) and heading (R(2) = 0.86) stages across water treatments. Leaf N also had a stronger association with the red-edge position (REP) at both stages (R(2) = 0.83 and 0.78), or with the ratio R4 (R760/R550) at jointing (R(2) = 0.88), than with chlorophyll meter (SPAD) readings. Under water stress, the predictive accuracy of leaf N increased with these reflectance indices, but decreased using SPAD readings. The results indicate that specific reflectance indices of FDRE, REP and R4 may be used for a rapid and non-destructive estimation of oat plant N status over a range of water regimes. © 2014 Her Majesty the Queen in Right of Canada Journal of the Science of Food and Agriculture © 2014 Society of Chemical Industry.
Orbital effects of spatial variations of fundamental coupling constants
NASA Astrophysics Data System (ADS)
Iorio, Lorenzo
2011-11-01
We deal with the effects induced on the orbit of a test particle revolving around a central body by putative spatial variations of dimensionless fundamental coupling constants ζ. In particular, we assume a dipole gradient for ? along a generic direction ? in space. We analytically work out the long-term variations of all the six standard osculating Keplerian orbital elements parameterizing the orbit of a test particle in a gravitationally bound two-body system. Apart from the semimajor axis a, the eccentricity e, the inclination I, the longitude of the ascending node Ω, the longitude of pericentre ϖ and the mean anomaly ? undergo non-zero long-term changes. By using the usual decomposition along the radial (R), transverse (T) and normal (N) directions, we also analytically work out the long-term changes ΔR, ΔT, ΔN and ΔvR, ΔvT, ΔvN experienced by the position and the velocity vectors r and v of the test particle. Apart from ΔN, all the other five shifts do not vanish over one full orbital revolution. In the calculation we do not use a priori simplifying assumptions concerning e and I. Thus, our results are valid for a generic orbital geometry; moreover, they hold for any gradient direction ?. We compare our predictions to the latest observational results for some of the major bodies of the solar system. The largest predicted planetary perihelion precessions occur for the rocky planets, amounting to some 10-2-10-3 mas per century. Apart from the Earth, they are 2 - 3 orders of magnitude smaller than the present-day accuracy in empirically determining the corrections ? to the standard Newtonian-Einsteinian planetary perihelion rates. Numerically integrated time-series of the interplanetary range for some Earth-planet pairs yield Stark-like signatures as large as 0.1-10 mm; future planned planetary laser ranging facilities should be accurate at a cm level. The long-term variations of the lunar eccentricity and perigee are of the order of 10-14 yr-1 and 10-4 mas yr-1, respectively, while the change ΔR in the radial component of the Moon's geocentric orbit is as large as 0.8 μm per orbit. A numerically calculated geocentric lunar range time-series has a maximum nominal peak-to-peak amplitude of just a few mm, with an average of 0.3 μm over 30 yr. The present-day accuracies in determining ? and ? for the Moon are 10-12 yr-1 and 10-1 mas yr-1, respectively. The Apollo facility should be able to determine on a continuous basis of the Earth-Moon range with a mm accuracy.
Groundwater quality characterization around Jawaharnagar open dumpsite, Telangana State
NASA Astrophysics Data System (ADS)
Unnisa, Syeda Azeem; Zainab Bi, Shaik
2017-11-01
In the present work groundwater samples were collected from ten different data points in and around Jawaharnagar municipal dumpsite, Telangana State Hyderabad city from May 2015 to May 2016 on monthly basis for groundwater quality characterization. Pearson's correlation coefficient ( r) value was determined using correlation matrix to identify the highly correlated and interrelated water quality standards issued by Bureau of Indian Standard (IS-10500:2012). It is found that most of the groundwater samples are above acceptable limits and are not potable. The chemical analysis results revealed that pH range from 7.2 to 7.8, TA 222 to 427 mg/l, TDS 512 to 854 mg/l, TH 420 to 584 mg/l, Calcium 115 to 140 mg/l, Magnesium 55 to 115 mg/l, Chlorides 202 to 290 mg/l, Sulphates 170 to 250 mg/l, Nitrates 6.5 to 11.3 mg/l, and Fluoride 0.9 to 1.7 mg/l. All samples showed higher range of physicochemical parameters except nitrate content which was lower than permissible limit. Highly positive correlation was observed between pH-TH ( r = 0.5063), TA-Cl- ( r = 0.5896), TDS-SO4 - ( r = 0.5125), Mg2+-NO3 - ( r = 0.5543) and Cl--F- ( r = 0.7786). The groundwater samples in and around Jawaharnagar municipal dumpsite implies that groundwater samples were contaminated by municipal leachate migration from open dumpsite. The results revealed that the systematic calculations of correlation coefficient between water parameters and regression analysis provide qualitative and rapid monitoring of groundwater quality.
Effective collision strengths for the electron impact excitation of Mg
NASA Astrophysics Data System (ADS)
Hudson, C. E.; Ramsbottom, C. A.; Norrington, P. H.; Scott, M. P.
2008-05-01
Electron impact excitation collision strengths for fine structure transitions of Mg,have been determined by a Breit-Pauli R-matrix calculation. The target states are represented by configuration interaction wavefunctions and consist of the 19 lowest LS states, having configurations 2s^22p^4, 2s2p^5, 2p^6, 2s^22p^33s and 2s^22p^33p. These target states give rise to 37 fine structure levels and 666 possible transitions. The effective collision strengths are calculated by averaging the electron collision strengths over a Maxwellian distribution of electron velocities. Effective collision strengths for transitions between the fine structure levels are given for electron temperatures in the range 10Te(K) = 3.0 - 7.0. Results are compared with the previous R-matrix calculation of Butler & Zeippen (AASS, 1994) and the recent Distorted Wave evaluations of Bhatia, Landi & Eissner (ADNDT, 2006).
Wu, Chunying; Gu, Feng; Bai, Lu; Lu, Wenlong
2015-08-01
An analytical method for simultaneous determination of 22 typical pharmaceuticals and personal care products (PPCPs) in environmental water samples was developed by ultra performance liquid chromatography-triple quadrupole mass spectrometry (UPLC-MS/MS). An Oasis HLB solid phase extraction cartridge, methanol as washing solution, water containing 0. 1% formic acid-methanol (7:3, v/v) as the mobile phases were selected for sample pretreatment and chromatographic separation. Based on the optimized sample pretreatment procedures and separation condition, the target recoveries ranged from 73% to 125% in water with the relative standard deviations ( RSDs) from 8.8% to 17.5%, and the linear ranges were from 2 to 2 000 µg/L with correlation coefficients (R2) not less than 0.997. The method can be applied to simultaneous determination of the 22 typical PPCPs in environmental water samples because of its low detection limits and high recoveries. It can provide support and help for the related research on water environmental risk assessment and control of the micro-organic pollutants.
NASA Technical Reports Server (NTRS)
Jameson, A. R.
1990-01-01
The relationship between the rainfall rate (R) obtained from radiometric brightness temperatures and the extinction coefficient (k sub e) is investigated by computing the values of k sub e over a wide range of rainfall rates, for frequencies from 3 to 25 GHz. The results show that the strength of the relation between the R and the k sub e values exhibits considerable variation for frequencies at this range. Practical suggestions are made concerning the selection of particular frequencies for rain measurements to minimize the error in R determinations.
NASA Astrophysics Data System (ADS)
Lamy, P. L.; Toth, I.; Weaver, H. A.; A'Hearn, M. F.; Jorda, L.
2011-04-01
We report on our on-going effort to detect and characterize cometary nuclei with the Hubble Space Telescope (HST). During cycle 9 (2000 July to 2001 June), we performed multi-orbit observations of 10 ecliptic comets with the Wide Field Planetary Camera 2. Nominally, eight contiguous orbits covering a time interval of ˜11 h were devoted to each comet but a few orbits were occasionally lost. In addition to the standard R band, we could additionally observe four of them in the V band and the two brightest ones in the B band. Time series photometry was used to constrain the size, shape and rotational period of the 10 nuclei. Assuming a geometric albedo of 0.04 for the R band, a linear phase law with a coefficient of 0.04 mag deg-1 and an opposition effect similar to that of comet 19P/Borrelly, we determined the following mean values of the effective radii 47P/Ashbrook-Jackson: 2.86±0.08 km, 61P/Shajn-Schaldach: 0.62±0.02 km, 70P/Kojima: 1.83±0.05 km, 74P/Smirnova-Chernykh: 2.23±0.04 km, 76P/West-Kohoutek-Ikemura: 0.30±0.02 km, 82P/Gehrels 3: 0.69±0.02 km, 86P/Wild 3: 0.41±0.03 km, 87P/Bus: 0.270.01 km, 110P/Hartley 3: 2.15±0.04 km and 147P/Kushida-Muramatsu: 0.21±0.01 km. Because of the limited time coverage (˜11 h), the rotational periods could not be accurately determined, multiple solutions were sometime found and three periods were not constrained at all. Our estimates range from ˜5 to ˜32 h. The lower limits for the ratio a/b of the semi-axis of the equivalent spheroids range from 1.10 (70P) to 2.20 (87P). The four nuclei for which we could measure (V-R) are all significantly redder than the Sun, with 86P/Wild 3 (V-R) = 0.86 ± 0.10 appearing as an ultrared object. We finally determined the dust activity parameter Afρ of their coma in the R band, the colour indices and the reflectivity spectra of four of them. Based on observations made with the NASA/ESA Hubble Space Telescope, obtained at Space Telescope Science Institute, which is operated by the Association of Universities for Research in Astronomy under NASA contract NAS 5-26555.
Short fatigue crack behavior in notched 2024-T3 aluminum specimens
NASA Technical Reports Server (NTRS)
Lee, J. J.; Sharpe, W. N., Jr.
1986-01-01
Single-edge, semi-circular notched specimens of Al 2024-T3, 2.3 mm thick, were cyclicly loaded at R-ratios of 0.5, 0.0, -1.0, and -2.0. The notch roots were periodically inspected using a replica technique which duplicates the bore surface. The replicas were examined under an optical microscope to determine the initiation of very short cracks and to monitor the growth of short cracks ranging in length from a few tens of microns to the specimen thickness. In addition to short crack growth measurements, the crack opening displacement (COD) was measured for surface cracks as short as 0.035 mm and for through-thickness cracks using the Interferometric Strain/Displacement Gage (ISDG), a laser-based optical technique. The growth rates of short cracks were faster than the long crack growth rates for R-ratios of -1.0 and -2.0. No significant difference between short and long crack growth rates was observed for R = 0.0. Short cracks had slower growth rates than long cracks for R = 0.5. The crack opening stresses measured for short cracks were smaller than those predicted for large cracks, with little difference appearing for positive R-ratios and large differences noted for negative R-ratios.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gadzhaliev, M. M.; Daunov, M. I.; Musaev, A. M., E-mail: akhmed-musaev@yandex.ru
The pressure dependence of permittivity χ of direct gap ZnO, CdTe, InSb, InAs, CdSnAs{sub 2}, and CdGeAs{sub 2} semiconductors in the hydrostatic pressure range from zero to 1 GPa is determined from the results of quantitative analysis of the pressure dependences of resistivity ρ(P) and Hall constant R{sub H}(P). It is found that the dielectric constant decreases upon an increase in pressure so that coefficient (dχ/d{sub P})/χ increases with (dE{sub g}/dP)/E{sub g}.
Model Filled Polymers. 6. Determination of the Crosslink Density of Polymeric Beads by Swelling
1990-08-22
7 References [1] M. Mooney , J. AppI. Phys., 11, 582 (1940). [2] R. S. Rivlin , and D. W. Sanders, Trans. Faraday Soc., 48, 200 (1952). [31 P. J. Flory...microbeads ranging in diameter from 0.2 to 1 p were prepared by emulsion polymerization in the absence of emulsifier [23]. Polytetrafluorethylene ( PTFE ...density of polymethyl methacrylate is 1.17 g/cm3 [201. Swelling A PTFE ultrafiltration membrane is weighed and inserted in a concave configuration
Code of Federal Regulations, 2012 CFR
2012-04-01
... approximately .33 miles, rejoining the 1,000-foot contour line; thence in a northerly and eventually a southerly.../R7W; thence south along the R6W/R7W range line approximately .5 miles back to the 1,000-foot contour... north along range line R3W/R4W approximately 2.25 miles, back to the 1,000-foot contour line; (9) Thence...
Code of Federal Regulations, 2014 CFR
2014-04-01
... approximately .33 miles, rejoining the 1,000-foot contour line; thence in a northerly and eventually a southerly.../R7W; thence south along the R6W/R7W range line approximately .5 miles back to the 1,000-foot contour... north along range line R3W/R4W approximately 2.25 miles, back to the 1,000-foot contour line; (9) Thence...
Code of Federal Regulations, 2013 CFR
2013-04-01
... approximately .33 miles, rejoining the 1,000-foot contour line; thence in a northerly and eventually a southerly.../R7W; thence south along the R6W/R7W range line approximately .5 miles back to the 1,000-foot contour... north along range line R3W/R4W approximately 2.25 miles, back to the 1,000-foot contour line; (9) Thence...
Nojavan, Yones; Kamankesh, Marzieh; Shahraz, Farzaneh; Hashemi, Maryam; Mohammadi, Abdorreza
2015-05-01
A novel technique for simultaneous determination of five folate derivatives in various food matrices was developed by ion pair-based dispersive liquid-liquid microextraction (IP-DLLME) combined with high-performance liquid chromatography (HPLC). In the proposed method, N-methyl-N,N-dioctyloctan-1-ammonium chloride (aliquat-336) was used as an ion-pair reagent. Effective variables of microextraction process were optimized. Under optimum conditions, the method yielded a linear calibration curve ranging from 1-200 ng g(-1) with correlation coefficients (r(2)) higher than 0.98. The relative standard deviation for the seven analyses was 5.2-7.4%. Enrichment factors for the five folates ranged between 108-135. Limits of detection were 2-4.1 ng g(-1). A comparison of this method with other methods described that the new proposed method is rapid and accurate, and gives very good enrichment factors and detection limits for determining five folate derivatives. The newly developed method was successfully applied for the determination of five folate derivatives in wheat flour, egg yolk and orange juice samples. Copyright © 2015 Elsevier B.V. All rights reserved.
-Sb Glasses at Low Temperatures
NASA Astrophysics Data System (ADS)
Souri, Dariush; Azizpour, Parvin; Zaliani, Hamideh
2014-09-01
Semiconducting glasses of the type 40TeO2-(60 - x) V2O5- xSb were prepared by rapid melt quenching and their dc electrical conductivity was measured in the temperature range 180-296 K. For these glassy samples, the dc electrical conductivity ranged from 2.26 × 10-7 S cm-1 to 1.11 × 10-5 S cm-1 at 296 K, indicating the conductivity is enhanced by increasing the V2O5 content. These experimental results could be explained on the basis of different mechanisms (based on polaron-hopping theory) in the different temperature regions. At temperatures above Θ D/2 (where Θ D is the Debye temperature), the non-adiabatic small polaron hopping (NASPH) model is consistent with the data, whereas at temperatures below Θ D/2, a T -1/4 dependence of the conductivity indicative of the variable range hopping (VRH) mechanism is dominant. For all these glasses crossover from SPH to VRH conduction was observed at a characteristic temperature T R ≤ Θ D/2. In this study, the hopping carrier density and carrier mobility were determined at different temperatures. N ( E F), the density of states at (or near) the Fermi level, was also determined from the Mott variables; the results were dependent on V2O5 content.
Reference values for CSF outflow resistance and intracranial pressure in healthy elderly.
Malm, Jan; Jacobsson, Johan; Birgander, Richard; Eklund, Anders
2011-03-08
The intracranial pressure (ICP) and CSF outflow resistance (R(out)) are essential to describe the dynamics of the CSF system. R(out) affects ICP, pulse amplitudes, CSF absorption, and the compliance of the system. The objective of this study was to determine the reference values in healthy elderly subjects. Elderly people (60-82 years), who considered themselves healthy, were recruited through an advertisement in the local newspaper. All were evaluated with a 3-T MRI. Subjects were eligible if they did not have any psychiatric or neurologic disorder or signs of advanced atherosclerotic disease. CSF resting pressure (ICP) and R(out) were determined by a constant pressure infusion method with the patient in the supine position. The study population consisted of 40 subjects (mean age 70 years; 23 women). The median ICP was 11.6 mm Hg (15.8 cmH(2)O) and the reference interval was ICP 7.8-14.3 mm Hg (10.6-19.4 cmH(2)O) (defined as 5th to 95th percentiles). The median R(out) was 8.6 mm Hg/mL/min. The variation in R(out) was large and not normally distributed. The 90th percentile of R(out) was 17.4 mm Hg/mL/min. This study reports reference values for ICP and R(out) and should be used for comparison when investigating disorders with suspected CSF dynamic disturbances in the elderly. ICP was in the same range as that reported in the young and middle-aged. The upper limit of R(out) was higher than previously believed to be the upper limit of normal for this age group.
Bates, Nathaniel A.; Myer, Gregory D.; Hewett, Timothy E.
2014-01-01
Anterior cruciate ligament injuries are common, expensive to repair, and often debilitate athletic careers. Robotic manipulators have evaluated knee ligament biomechanics in cadaveric specimens, but face limitations such as accounting for variation in bony geometry between specimens that may influence dynamic motion pathways. This study examined individual anthropometric measures for significant linear relationships with in vivo kinematic and kinetic performance and determined their implications for robotic studies. Anthropometrics and 3D motion during a 31 cm drop vertical jump task were collected in high school female basketball players. Anthropometric measures demonstrated differential statistical significance in linear regression models relative to kinematic variables (P-range < 0.01-0.95). However, none of the anthropometric relationships accounted for clinical variance or provided substantive univariate accuracy needed for clinical prediction algorithms (r2 < 0.20). Mass and BMI demonstrated models that were significant (P < 0.05) and predictive (r2 > 0.20) relative to peak flexion moment, peak adduction moment, flexion moment range, abduction moment range, and internal rotation moment range. The current findings indicate that anthropometric measures are less associated with kinematics than with kinetics. Relative to the robotic manipulation of cadaveric limbs, the results do not support the need to normalize kinematic rotations relative to specimen dimensions. PMID:25266933
Wu, Yuanyuan; Boonloed, Anukul; Sleszynski, Neal; Koesdjojo, Myra; Armstrong, Chadd; Bracha, Shay; Remcho, Vincent T
2015-08-25
Rapidly increasing healthcare costs in economically advantaged countries are currently unsustainable, while in many developing nations, even 50-year-old technologies are too expensive to implement. New and unconventional technologies are being explored as solutions to this problem. In this study, we examined the use of a smartphone as the detection platform for 2 well-developed, relatively inexpensive, commercially available clinical chemistry assays as a model for rapid and inexpensive clinical diagnostic testing. An Apple iPhone 4 camera phone equipped with a color analysis application (ColorAssist) was combined with Vitros® glucose and urea colorimetric assays. Color images of assay slides at various concentrations of glucose or urea were collected with the iPhone 4 and quantitated in three different spectral ranges (red/green/blue or RGB) using the ColorAssist app. When the diffuse reflectance data was converted into absorbance, it was possible to quantitate glucose or blood urea nitrogen (BUN) over their clinically important concentration ranges (30-515mg/dl for glucose or 2-190mg/dl for BUN), with good linearity (R(2)=0.9994 or 0.9996, respectively [n=5]). Data collected using the iPhone 4 and canine serum samples were in agreement with results from the instrumental "gold standard" (Beckman Coulter AU480 Chemistry System) (R(2)=0.9966 and slope=1.0001 for glucose; R(2)=0.9958 and slope=0.9454 for BUN). Glucose determinations of serum samples made using this smartphone method were as accurate as or more accurate than a commercial colorimetric dry slide analyzer (Heska® Element DC Chemistry Analyzer, Loveland, CO) and 2 glucometers: ReliOn® Ultima (Abbott Diabetes Care Inc) and Presto® (AgaMatrix Inc.H). BUN determinations made using the smartphone approach were comparable in accuracy to the Heska instrument. This demonstration shows that smartphones have the potential to be used as simple, effective colorimetric detectors for quantitative diagnostic tests, and may be applicable for both point-of-care applications in the developed world and field deployment in developing nations. Copyright © 2015 Elsevier B.V. All rights reserved.
Human autonomic rhythms: vagal cardiac mechanisms in tetraplegic subjects
NASA Technical Reports Server (NTRS)
Koh, J.; Brown, T. E.; Beightol, L. A.; Ha, C. Y.; Eckberg, D. L.
1994-01-01
1. We studied eight young men (age range: 20-37 years) with chronic, clinically complete high cervical spinal cord injuries and ten age-matched healthy men to determine how interruption of connections between the central nervous system and spinal sympathetic motoneurones affects autonomic cardiovascular control. 2. Baseline diastolic pressures and R-R intervals (heart periods) were similar in the two groups. Slopes of R-R interval responses to brief neck pressure changes were significantly lower in tetraplegic than in healthy subjects, but slopes of R-R interval responses to steady-state arterial pressure reductions and increases were comparable. Plasma noradrenaline levels did not change significantly during steady-state arterial pressure reductions in tetraplegic patients, but rose sharply in healthy subjects. The range of arterial pressure and R-R interval responses to vasoactive drugs (nitroprusside and phenylephrine) was significantly greater in tetraplegic than healthy subjects. 3. Resting R-R interval spectral power at respiratory and low frequencies was similar in the two groups. During infusions of vasoactive drugs, low-frequency R-R interval spectral power was directly proportional to arterial pressure in tetraplegic patients, but was unrelated to arterial pressure in healthy subjects. Vagolytic doses of atropine nearly abolished both low- and respiratory-frequency R-R interval spectral power in both groups. 4. Our conclusions are as follows. First, since tetraplegic patients have significant levels of low-frequency arterial pressure and R-R interval spectral power, human Mayer arterial pressure waves may result from mechanisms that do not involve stimulation of spinal sympathetic motoneurones by brainstem neurones. Second, since in tetraplegic patients, low-frequency R-R interval spectral power is proportional to arterial pressure, it is likely to be mediated by a baroreflex mechanism. Third, since low-frequency R-R interval rhythms were nearly abolished by atropine in both tetraplegic and healthy subjects, these rhythms reflect in an important way rhythmic firing of vagal cardiac motoneurones.
Leytem, A B; Kwanyuen, P; Plumstead, P W; Maguire, R O; Brake, J
2008-01-01
Using 31-phosphorus nuclear magnetic resonance spectroscopy ((31)P-NMR) to characterize phosphorus (P) in animal manures and litter has become a popular technique in the area of nutrient management. To date, there has been no published work evaluating P quantification in manure/litter samples with (31)P-NMR compared to other accepted methods such as high performance liquid chromatography (HPLC). To evaluate the use of (31)P-NMR to quantify myo-inositol hexakisphosphate (phytate) in ileal digesta, manure, and litter from broilers, we compared results obtained from both (31)P-NMR and a more traditional HPLC method. The quantification of phytate in all samples was very consistent between the two methods, with linear regressions having slopes ranging from 0.94 to 1.07 and r(2) values of 0.84 to 0.98. We compared the concentration of total monoester P determined with (31)P-NMR with the total inositol P content determined with HPLC and found a strong linear relationship between the two measurements having slopes ranging from 0.91 to 1.08 and r(2) values of 0.73 to 0.95. This suggests that (31)P-NMR is a very reliable method for quantifying P compounds in manure/litter samples.
Stanković, Dalibor M
2015-10-01
Essential oil of Carum copticum seeds, obtained from a local shop, was extracted and content of thymol was analyzed using square-wave voltammetry at boron-doped diamond electrode. The effect of various parameters, such as pH of supporting electrolyte and square-wave voltammetric parameters (modulation amplitude and frequency), was examined. In Britton-Robinson buffer solution (pH 4), thymol provided a single and oval-shaped irreversible oxidation peak at +1.13 V versus silver/silver chloride potassium electrode (3M). Under optimal experimental conditions, a plot of peak height against concentration of thymol was found to be linear over the range of 4 to 100μM consisting of two linear ranges: from 4 to 20μM (R(2)=0.9964) and from 20 to 100μM (R(2)=0.9993). The effect of potential interferences such as p-cymene and γ-terpinene (major components in essential oil of C. copticum seeds) was evaluated. Thus, the proposed method displays a sufficient selectivity toward thymol with a detection limit of 3.9μM, and it was successfully applied for the determination of thymol in essential oil of C. copticum seeds. The Prussian blue method was used for validation of the proposed electroanalytical method. Copyright © 2015 Elsevier Inc. All rights reserved.
Alshana, Usama; Ertaş, Nusret; Göğer, Nilgün G
2015-08-15
Dispersive liquid-liquid microextraction (DLLME) with back-extraction was used prior to capillary electrophoresis (CE) for the extraction of four parabens. Optimum extraction conditions were: 200 μL chloroform (extraction solvent), 1.0 mL acetonitrile (disperser solvent) and 1 min extraction time. Back-extraction of parabens from chloroform into a 50mM sodium hydroxide solution within 10s facilitated their direct injection into CE. The analytes were separated at 12°C and 25 kV with a background electrolyte of 25 mM borate buffer containing 5.0% (v/v) acetonitrile. Enrichment factors were in the range of 4.3-10.7 and limits of detection ranged from 0.1 to 0.2 μg mL(-1). Calibration graphs showed good linearity with coefficients of determination (R(2)) higher than 0.9957 and relative standard deviations (%RSDs) lower than 3.5%. DLLME-CE was demonstrated to be a simple and rapid method for the determination of parabens in human milk and food with relative recoveries in the range of 86.7-103.3%. Copyright © 2015 Elsevier Ltd. All rights reserved.
Zong, Shi-Yu; Han, Han; Wang, Bing; Li, Ning; Dong, Tina Ting-Xia; Zhang, Tong; Tsim, Karl W K
2015-12-04
A reliable ultra-high-performance liquid chromatography-electrospray ionization-tandem mass spectrometry (UHPLC-ESI-MS/MS) method for the fast simultaneous determination of 13 nucleosides and nucleobases in Cordyceps sinensis (C. sinensis) with 2-chloroadenosine as internal standard was developed and validated. Samples were ultrasonically extracted in an ice bath thrice, and the optimum analyte separation was performed on an ACQUITY UPLC(TM) HSS C18 column (100 mm × 2.1 mm, 1.8 μm) with gradient elution. All targeted analytes were separated in 5.5 min. Furthermore, all calibration curves showed good linear regression (r > 0.9970) within the test ranges, and the limits of quantitation and detection of the 13 analytes were less than 150 and 75 ng/mL, respectively. The relative standard deviations (RSDs) of intra- and inter-day precisions were <6.23%. Recoveries of the quantified analytes ranged within 85.3%-117.3%, with RSD < 6.18%. The developed UHPLC-ESI-MS/MS method was successfully applied to determine nucleosides and nucleobases in 11 batches of C. sinensis samples from different regions in China. The range for the total content in the analyzed samples was 1329-2057 µg/g.
Tojo, H; Ejiri, A; Hiratsuka, J; Yamaguchi, T; Takase, Y; Itami, K; Hatae, T
2012-02-01
This paper presents an experimental demonstration to determine electron temperature (T(e)) with unknown spectral sensitivity (transmissivity) in a Thomson scattering system. In this method, a double-pass scattering configuration is used and the scattered lights from each pass (with different scattering angles) are measured separately. T(e) can be determined from the ratio of the signal intensities without knowing a real chromatic dependence in the sensitivity. Note that the wavelength range for each spectral channel must be known. This method was applied to the TST-2 Thomson scattering system. As a result, T(e) measured from the ratio (T(e,r)) and T(e) measured from a standard method (T(e,s)) showed a good agreement with <∣T(e,r) - T(e,s)∣∕T(e,s)> = 7.3%.
Novel Heteroaryl Selenocyanates and Diselenides as Potent Antileishmanial Agents
Baquedano, Ylenia; Alcolea, Verónica; Toro, Miguel Ángel; Gutiérrez, Killian Jesús; Nguewa, Paul; Font, María; Moreno, Esther; Espuelas, Socorro; Jiménez-Ruiz, Antonio; Palop, Juan Antonio; Plano, Daniel
2016-01-01
A series of new selenocyanates and diselenides bearing interesting bioactive scaffolds (quinoline, quinoxaline, acridine, chromene, furane, isosazole, etc.) was synthesized, and their in vitro leishmanicidal activities against Leishmania infantum amastigotes along with their cytotoxicities in human THP-1 cells were determined. Interestingly, most tested compounds were active in the low micromolar range and led us to identify four lead compounds (1h, 2d, 2e, and 2f) with 50% effective dose (ED50) values ranging from 0.45 to 1.27 μM and selectivity indexes of >25 for all of them, much higher than those observed for the reference drugs. These active derivatives were evaluated against infected macrophages, and in order to gain preliminary knowledge about their possible mechanism of action, the inhibition of trypanothione reductase (TryR) was measured. Among these novel structures, compounds 1h (3,5-dimethyl-4-isoxazolyl selenocyanate) and 2d [3,3′-(diselenodiyldimethanediyl)bis(2-bromothiophene)] exhibited good association between TryR inhibitory activity and antileishmanial potency, pointing to 1h, for its excellent theoretical ADME (absorption, distribution, metabolism, and excretion) properties, as the most promising lead molecule for leishmancidal drug design. PMID:27067328
Novel Heteroaryl Selenocyanates and Diselenides as Potent Antileishmanial Agents.
Baquedano, Ylenia; Alcolea, Verónica; Toro, Miguel Ángel; Gutiérrez, Killian Jesús; Nguewa, Paul; Font, María; Moreno, Esther; Espuelas, Socorro; Jiménez-Ruiz, Antonio; Palop, Juan Antonio; Plano, Daniel; Sanmartín, Carmen
2016-06-01
A series of new selenocyanates and diselenides bearing interesting bioactive scaffolds (quinoline, quinoxaline, acridine, chromene, furane, isosazole, etc.) was synthesized, and their in vitro leishmanicidal activities against Leishmania infantum amastigotes along with their cytotoxicities in human THP-1 cells were determined. Interestingly, most tested compounds were active in the low micromolar range and led us to identify four lead compounds (1h, 2d, 2e, and 2f) with 50% effective dose (ED50) values ranging from 0.45 to 1.27 μM and selectivity indexes of >25 for all of them, much higher than those observed for the reference drugs. These active derivatives were evaluated against infected macrophages, and in order to gain preliminary knowledge about their possible mechanism of action, the inhibition of trypanothione reductase (TryR) was measured. Among these novel structures, compounds 1h (3,5-dimethyl-4-isoxazolyl selenocyanate) and 2d [3,3'-(diselenodiyldimethanediyl)bis(2-bromothiophene)] exhibited good association between TryR inhibitory activity and antileishmanial potency, pointing to 1h, for its excellent theoretical ADME (absorption, distribution, metabolism, and excretion) properties, as the most promising lead molecule for leishmancidal drug design. Copyright © 2016, American Society for Microbiology. All Rights Reserved.
Cape Photographic Durchmusterung, volume 2
NASA Technical Reports Server (NTRS)
1993-01-01
The Cape Photographic Durchmusterung (CPD, Gill and Kapteyn 1895-1900) is a Photographic survey of southern stars in the declination range -18 to -90 degrees. This volume covers the declination range -53 through -89 degrees. Positions are given for 1875 equinox. The summary of the positional uncertainties quoted in the third volume of the published catalog gives +/- 0.28 sec (R.A.), +/- 0.044 arcmin (Dec.) for zones - 18 to -57 degrees, + 0.157 sec + 0.0764/cos(delta) sec (R.A.), +/- 0.056 arcmin (Dec.) for zones -58 to -85 degrees, +0.157 sec + 0.0353/cos (delta) sec (R.A.), + 0.0127 arcmin (Dec.) for the polar plate where, as explained in the introduction to the third volume, many positions were derived from rectangular coordinates (these are positions reported to 0.1 SCC (R.A.) and 0.001 arcmin (Dec.) in the -86 to -89 degree zones in the catalog). The probable error of a photographic magnitude, as determined by combining results for different magnitudes and weighting proportionately according to the numbers of stars in each class of magnitude, is given as +0.055 mag. From an analysis of the faint magnitude limits on the plates discussed in the third volume introduction, the catalog as a whole can be considered complete to photographic magnitude 9.2, but it is stated that it will be found practically complete, in or near the Milky Way, to magnitude 9.5.
NASA Astrophysics Data System (ADS)
Wood, John; Smyth, Tim J.; Estellés, Victor
2017-05-01
We have developed two hyperspectral radiometer systems which require no moving parts, shade rings or motorised tracking, making them ideally suited for autonomous use in the inhospitable remote marine environment. Both systems are able to measure direct and diffuse hyperspectral irradiance in the wavelength range 350-1050 nm at 6 nm (Spectrometer 1) or 3.5 nm (Spectrometer 2) resolution. Marine field trials along a 100° transect (between 50° N and 50° S) of the Atlantic Ocean resulted in close agreement with existing commercially available instruments in measuring (1) photosynthetically available radiation (PAR), with both spectrometers giving regression slopes close to unity (Spectrometer 1: 0.960; Spectrometer 2: 1.006) and R2 ˜ 0.96; (2) irradiant energy, with R2 ˜ 0.98 and a regression slope of 0.75 which can be accounted for by the difference in wavelength integration range; and (3) hyperspectral irradiance where the agreement on average was between 2 and 5 %. Two long duration land-based field campaigns of up to 18 months allowed both spectrometers to be well calibrated. This was also invaluable for empirically correcting for the wider field of view (FOV) of the spectrometers in comparison with the current generation of sun photometers ( ˜ 7.5° compared with ˜ 1°). The need for this correction was also confirmed and independently quantified by atmospheric radiative transfer modelling and found to be a function of aerosol optical depth (AOD) and solar zenith angle. Once Spectrometer 2 was well calibrated and the FOV effect corrected for, the RMSE in retrievals of AOD when compared with a CIMEL sun photometer were reduced to ˜ 0.02-0.03 with R2 > 0.95 at wavelengths 440, 500, 670 and 870 nm. Corrections for the FOV as well as ship motion were applied to the data from the marine field trials. This resulted in AOD500 nm ranging between 0.05 in the clear background marine aerosol regions and ˜ 0.5 within the Saharan dust plume. The RMSE between the handheld Microtops sun photometer and Spectrometer 2 was between 0.047 and 0.057 with R2 > 0.94.
Development and Validation of GC-ECD Method for the Determination of Metamitron in Soil
Tandon, Shishir; Kumar, Satyendra; Sand, N. K.
2015-01-01
This paper aims at developing and validating a convenient, rapid, and sensitive method for estimation of metamitron from soil samples.Determination andquantification was carried out by Gas Chromatography on microcapillary column with an Electron Capture Detector source. The compound was extracted from soil using methanol and cleanup by C-18 SPE. After optimization, the method was validated by evaluating the analytical curves, linearity, limits of detection, and quantification, precision (repeatability and intermediate precision), and accuracy (recovery). Recovery values ranged from 89 to 93.5% within 0.05- 2.0 µg L−1 with average RSD 1.80%. The precision (repeatability) ranged from 1.7034 to 1.9144% and intermediate precision from 1.5685 to 2.1323%. Retention time was 6.3 minutes, and minimum detectable and quantifiable limits were 0.02 ng mL−1 and 0.05 ng g−1, respectively. Good linearity (R 2 = 0.998) of the calibration curves was obtained over the range from 0.05 to 2.0 µg L−1. Results indicated that the developed method is rapid and easy to perform, making it applicable for analysis in large pesticide monitoring programmes. PMID:25733978
Determination of Time since Death using Vitreous Humor Tryptophan.
Ansari, Niha; Menon, Shobhana K
2017-09-01
Determination of time since death (TSD) plays very important role in forensic examination as it narrows down field of suspects and aids in deceased identification. This study utilizes the fluorescence property of vitreous humor (VH) tryptophan to determine TSD using o-phthalaldehyde (OPA). The detection limit of these fluorometric studies was found to be 8 ppb indicating sensitivity and high accuracy in TSD determination. The study was performed on selected 76 cadaver with known TSD ranging from 3 to 90 h. Excellent correlation between VH tryptophan and TSD was obtained with a coefficient of correlation R 2 = 0.9590. Results showed statistically significant increase in vitreous tryptophan with TSD up to 90 h, and the proposed method was efficaciously applied for prediction of TSD as no systematic error exist. The regression equation obtained from the study is [Trp] = 2.21 + 2.98 * TSD. © 2017 American Academy of Forensic Sciences.
Bavan, Selvan; Farmer, Louise; Singh, Shire K.; Straub, Volko A.; Guerrero, Felix D.
2011-01-01
P2X ion channels have been functionally characterized from a range of eukaryotes. Although these receptors can be broadly classified into fast and slow desensitizing, the molecular mechanisms underlying current desensitization are not fully understood. Here, we describe the characterization of a P2X receptor from the cattle tick Boophilus microplus (BmP2X) displaying extremely slow current kinetics, little desensitization during ATP application, and marked rundown in current amplitude between sequential responses. ATP (EC50, 67.1 μM) evoked concentration-dependent currents at BmP2X that were antagonized by suramin (IC50, 4.8 μM) and potentiated by the antiparasitic drug amitraz. Ivermectin did not potentiate BmP2X currents, but the mutation M362L conferred ivermectin sensitivity. To investigate the mechanisms underlying slow desensitization we generated intracellular domain chimeras between BmP2X and the rapidly desensitizing P2X receptor from Hypsibius dujardini. Exchange of N or C termini between these fast- and slow-desensitizing receptors altered the rate of current desensitization toward that of the donor channel. Truncation of the BmP2X C terminus identified the penultimate residue (Arg413) as important for slow desensitization. Removal of positive charge at this position in the mutant R413A resulted in significantly faster desensitization, which was further accentuated by the negatively charged substitution R413D. R413A and R413D, however, still displayed current rundown to sequential ATP application. Mutation to a positive charge (R413K) reconstituted the wild-type phenotype. This study identifies a new determinant of P2X desensitization where positive charge at the end of the C terminal regulates current flow and further demonstrates that rundown and desensitization are governed by distinct mechanisms. PMID:21212138
Suzuki, Kunio; Sakai, D K
2007-03-13
Quantification of msa gene mRNA of Renibacterium salmoninarum, the causative agent of bacterial kidney disease (BKD), was investigated using reverse transcription followed by real-time PCR assay on R. salmoninarum in culture, and in experimentally challenged chum salmon Oncorhynchus keta fry kidney tissues (total of 70 samples) after intraperitoneal (i.p.) injection and bath infection. Correlations of msa gene mRNA concentrations with culturable cell concentrations (as colony forming units [CFU]), determined by drop-plate culture method on selective kidney disease medium (SKDM) agar through a 12 wk incubation time, and msa gene DNA concentrations by real-time PCR assay were examined. Furthermore, ovarian fluid samples from wild chum salmon adults with no clinical signs of disease were collected from 8 rivers and from clinically infected kokanee 0. nerka and masu salmon O. masou that were reared in 1 and 2 hatcheries, respectively (total of 414 samples). All samples were examined by nested PCR assay. Then, positive samples were examined by real-time PCR assays for mRNA and DNA; mRNA was detectable at 8 log units (5.0 x 101 to 5.0 x 10(9) copies p11(-1)) with high correlation (R2 = 0.999). The mRNA concentration correlated with CFU in kidney tissue from fish infected by i.p. injection (R2 = 0.924), by bath infection (R2 = 0.502) and in culture (R2 = 0.888). R. salmoninarum was detected and quantified by real-time PCR assay for mRNA in ovarian fluid samples in both subclinically infected chum salmon adults and clinically infected kokanee and masu salmon adults; detection rates ranged from 0 to 44.4% and concentrations ranged from 9.7 x 10(2) to 5.6 x 10(5) copies pl(-1). These results indicate that real-time PCR assay for the mRNA is a rapid, sensitive and reliable method to detect and quantify the viability of R. salmoninarum in kidney and ovarian fluid samples of salmonid fishes with both clinical and subclinical infection of the pathogen.
Wolfe, C J; Haygood, M G
1993-08-01
Ribosomal RNA (rRNA) operon copy number and gene order were determined for the luminous bacterial symbiont of Kryptophanaron alfredi, an anomalopid (flashlight) fish, and estimated for the luminous symbionts of 3 other fish families and of 3 luminous seawater isolates. Compared with the seawater isolates and other fish symbionts, the copy number of rRNA genes in the K. alfredi symbiont was radically reduced, although gene order appeared conserved among all the strains. The K. alfredi symbiont possesses only a single rRNA operon, whereas the other strains examined have minimum copy numbers ranging from 8 to 11. No difference in copy number was observed between light organ and seawater isolates of the same species, or between isolates of the same species from the light organs of 2 different host families. Thus, the anomalopid symbiosis appears unique among characterized light organ symbioses.
Dong, Changsheng; Wang, Haidong; Xue, Linli; Dong, Yanjun; Yang, Lei; Fan, Ruiwen; Yu, Xiuju; Tian, Xue; Ma, Shuhui; Smith, George W.
2012-01-01
Coat color is a key economic trait in wool-producing species. Color development and pigmentation are controlled by complex mechanisms in animals. Here, we report the first production of an altered coat color by overexpression of miR-137 in transgenic mice. Transgenic mice overexpressing miR-137 developed a range of coat color changes from dark black to light color. Molecular analyses of the transgenic mice showed decreased expression of the major target gene termed MITF and its downstream genes, including TYR, TYRP1, and TYRP2. We also showed that melanogenesis altered by miR-137 is distinct from that affected by UV radiation in transgenic mice. Our study provides the first mouse model for the study of coat color controlled by miRNAs in animals and may have important applications in wool production. PMID:22847819
Thin Layer Drying Model of Bacterial Cellulose Film
NASA Astrophysics Data System (ADS)
Hadi Jatmiko, Tri; Taufika Rosyida, Vita; Wheni Indrianingsih, Anastasia; Apriyana, Wuri
2017-12-01
The bacterial cellulose film produced by Acetobacter xylinum using coconut water as a carbon source was dried at a temperature of 60 to 100 C. The drying process of bacterial cellulose film occur at falling rate drying period. Increasing drying temperature will shorten the drying time. The drying data fitted with thin layer drying models that widely used, Newton, Page and Henderson and Pabis models. All thin layer drying models describe the experimental data well, but Page model is better than the other models on all various temperature with coefficients of determination (R2) range from 0.9908 to 0.9979, chi square range from 0.000212 to 0.000851 and RMSE range from 0.014307 to 0.0289458.
Li, Weiguo; Zhang, Zhuoli; Gordon, Andrew C.; Chen, Jeane; Nicolai, Jodi; Lewandowski, Robert J.; Omary, Reed A.
2016-01-01
Purpose To investigate the qualitative and quantitative impacts of labeling yttrium microspheres with increasing amounts of superparamagnetic iron oxide (SPIO) material for magnetic resonance (MR) imaging in phantom and rodent models. Materials and Methods Animal model studies were approved by the institutional Animal Care and Use Committee. The r2* relaxivity for each of four microsphere SPIO compositions was determined from 32 phantoms constructed with agarose gel and in eight concentrations from each of the four compositions. Intrahepatic transcatheter infusion procedures were performed in rats by using each of the four compositions before MR imaging to visualize distributions within the liver. For quantitative studies, doses of 5, 10, 15, or 20 mg 2% SPIO-labeled yttrium microspheres were infused into 24 rats (six rats per group). MR imaging R2* measurements were used to quantify the dose delivered to each liver. Pearson correlation, analysis of variance, and intraclass correlation analyses were performed to compare MR imaging measurements in phantoms and animal models. Results Increased r2* relaxivity was observed with incremental increases of SPIO microsphere content. R2* measurements of the 2% SPIO–labeled yttrium microsphere concentration were well correlated with known phantom concentrations (R2 = 1.00, P < .001) over a broader linear range than observed for the other three compositions. Microspheres were heterogeneously distributed within each liver; increasing microsphere SPIO content produced marked signal voids. R2*-based measurements of 2% SPIO–labeled yttrium microsphere delivery were well correlated with infused dose (intraclass correlation coefficient, 0.98; P < .001). Conclusion MR imaging R2* measurements of yttrium microspheres labeled with 2% SPIO can quantitatively depict in vivo intrahepatic biodistribution in a rat model. © RSNA, 2015 Online supplemental material is available for this article. PMID:26313619
PLS-NIR determination of five parameters in different types of Chinese rice wine
NASA Astrophysics Data System (ADS)
Yu, Haiyan; Ying, Yibin; Fu, Xiaping; Lu, Huishan
2005-11-01
To evaluate the applicability of near infrared spectroscopy for determination of the five enological parameters (alcoholic degree, pH value, total acid and amino acid nitrogen, °Brix) of Chinese rice wine, transmission spectra were collected in the spectral range from 12500 to 3800 cm-1 in a 1 mm path length rectangular quartz cuvette with air as reference at room temperature. Five calibration equations for the five parameters were established between the reference data and spectra by partial least squares (PLS) regression, separately. The best calibration results were achieved for the determination of alcoholic degree and °Brix. The RPD (ration of the standard deviation of the samples to the SECV) values of the calibration for both alcoholic degree and °Brix were higher than 3 (4.30 and 7.94, respectively), which demonstrated the robustness and power of the calibration models. The determination coefficients (R2) for alcoholic degree and °Brix were 0.987 and 0.991, respectively. The performance of pH, total acid and amino acid nitrogen was not as good as that of alcoholic degree and °Brix. The RPD values for the three parameters were 1.48, 1.85 and 1.82, respectively, and R2 values were 0.964, 0.970 and 0.971, respectively. In validation step, R2 value of the five parameters are all higher than 0.7, especially for alcoholic degree and °Brix (0.968 and 0.956, respectively). The results demonstrated that NIR spectroscopy could be used to predict the concentration of the five enological parameters in Chinese rice wine.
Zacs, Dzintars; Rjabova, Jekaterina; Bartkevics, Vadims
2013-08-20
The contamination profiles of polybrominated dibenzo-p-dioxins (PBDDs), dibenzofurans (PBDFs), diphenyl ethers (PBDEs), and mixed monobromo/chloro dibenzo-p-dioxins (PXDDs) and dibenzofurans (PXDFs) were determined in the tissue of Baltic wild salmon and compared with those of polychlorinated dibenzo-p-dioxins (PCDDs), dibenzofurans (PCDFs), and biphenyls (PCBs). Out of the analyzed PXDD/DFs, only the 3-B-2,7,8-triCDF was detected (in the concentration range of 0.039-0.075 pg g(-1) fresh weight (f.w.)). The toxic equivalents (TEQs) for analyzed PBDD/DFs (0.074-0.142 pg TEQ g(-1) f.w.) were found to contribute on average 2.1% to the total PCDD/DF-PBDD/DF-TEQ. The total concentrations of 27 PBDE congeners were in the range of 1.3-5.6 ng g(-1) f.w., with an average of 3.3 ng g(-1) f.w. The levels of PCDD/DFs and PCBs were found to be in the range of 4.53-14.6 pg WHO(2005)-PCDD/DF-PCB-TEQ g(-1) f.w., and concentrations of these compounds in most of the analyzed samples were above the maximum levels specified in Commission Regulation (EU) No. 1259/2011. Good correlation was observed between WHO(2005)-PCDD/DF-TEQ and WHO(2005)-PCB-TEQ (r(2) = 0.98), and these parameters were well correlated with the total sum of PBDE concentrations (r(2) = 0.91 and r(2) = 0.94, respectively). The results suggest that the consumption of Baltic wild salmon has no crucial impact on the average POP intake for typical Latvians.
Promising Sparingly Alloyed Boron-Bearing Steels for the Production of High-Strength Fasteners
NASA Astrophysics Data System (ADS)
Bobylev, M. V.; Koroleva, E. G.; Shtannikov, P. A.
2005-05-01
The main advantages of boron-bearing steels used for production of rolled sections at cold upset shops of Russian automotive plants are considered. A thermodynamic model for the majority of boron-bearing steels for high-strength fasteners is used to plot nomograms characterizing the effect of titanium, aluminum, nitrogen, and boron on the amount of nitrides and oxides segregated in crystallization and on the content of effective boron. The effect of effective boron on the characteristics of hardenability is estimated. The studies conducted are used for determining the range of permissible contents of titanium and aluminum ensuring through hardenability of rolled bars from steels 12G1R, 20G2R, and 30G1R up to 25 mm in diameter.
Feng, Fei; Yao, Yunjun; Liu, Meng
2017-01-01
Estimating cropland latent heat flux (LE) from continental to global scales is vital to modeling crop production and managing water resources. Over the past several decades, numerous LE models were developed, such as the moderate resolution imaging spectroradiometer LE (MOD16) algorithm, revised remote sensing-based Penman–Monteith LE algorithm (RRS), the Priestley–Taylor LE algorithm of the Jet Propulsion Laboratory (PT-JPL) and the modified satellite-based Priestley-Taylor LE algorithm (MS-PT). However, these LE models have not been directly compared over the global cropland ecosystem using various algorithms. In this study, we evaluated the performances of these four LE models using 34 eddy covariance (EC) sites. The results showed that mean annual LE for cropland varied from 33.49 to 58.97 W/m2 among the four models. The interannual LE slightly increased during 1982–2009 across the global cropland ecosystem. All models had acceptable performances with the coefficient of determination (R2) ranging from 0.4 to 0.7 and a root mean squared error (RMSE) of approximately 35 W/m2. MS-PT had good overall performance across the cropland ecosystem with the highest R2, lowest RMSE and a relatively low bias. The reduced performances of MOD16 and RRS, with R2 ranging from 0.4 to 0.6 and RMSEs from 30 to 39 W/m2, might be attributed to empirical parameters in the structure algorithms and calibrated coefficients. PMID:28837704
Fan, Wenying; Mao, Xiangju; He, Man; Chen, Beibei; Hu, Bin
2013-11-29
tIn this work, polyethyleneglycol (PEG)/hydroxyl polydimethylsiloxane (OH-PDMS)/γ -mercaptopropyltrimethoxysilane (γ -MPTS) coated stir bar was prepared by sol–gel process and its extraction performance for the extraction of amphoteric thyroxines (3,3',5,5'-tetraiodothyronin, T(4); 3,3',5-triiodothyronine, T(3); reversed-3,3',5-triiodothyronine, rT(3)) and their metabolite (3,5-diiodothyronine,T2) was studied. The preparation reproducibility of PEG/OH-PDMS/γ -MPTS coated stir bar was investigated, and the relative standard deviations (RSDs) in the same batch and among different batches were 3.3–14.3% (n = 5) and 7.7–16.6% (n = 3), respectively. The prepared PEG/OH-PDMS/γ -MPTS coated stir bar could be reused for more than 20 times. Based on this fact, a novel method of stir bar sorptive extraction (SBSE) combined with high performance liquid chromatography (HPLC)-ultraviolet (UV)and HPLC-inductively coupled plasma mass spectrometry (ICP-MS) for the analysis of target thyroxinesin human urine samples was developed. The influencing factors of SBSE, such as sample pH, extraction time, stirring rate, salt effect, desorption solution and desorption time, were studied in detail, and the analytical performance of the proposed method was evaluated under the optimized conditions. The enrichment factors (EFs) of the developed method for four target thyroxines were in the range of 14.9–70.4(theoretical enrichment factor was 100). The RSDs were ranging from 4.0% to 13.8% for SBSE-HPLC-UV (c = 25 μg/L, n = 6) and from 3.7% to 6.1% for SBSE-HPLC-ICP-MS (c = 0.5 μg/L, n = 5). The linear range obtained by SBSE-HPLC-UV was 2–500 μg/L for T(2)and 5–500 μg/L for rT3, T(3)and T(4), with correlation coefficients (r) ranging from 0.9957 to 0.9998, respectively, while the linear range obtained by SBSE-HPLC-ICP-MS was 0.05–500 μg/L for T(2) and rT(3), 0.10–200 μg/L for T(3) and 0.05–200 μg/L for T(4)with r ranging from 0.9979 to 0.9998, respectively. The limits of detection (LODs) for the target thyroxines were 0.60–2.20 μg/L for SBSE-HPLC-UV and 0.0071–0.0355 μg/L SBSE-HPLC-ICP-MS, respectively. The developed method was applied for the determination of target thyroxines in urine samples, and the recovery for the spiking samples obtained by SBSE-HPLC-UV was in the range of 81.6–137.6% for human urine,while the recovery for the spiking urine samples obtained by SBSE-HPLC-ICP-MS were in the range of 72.0–121.5%.
R-134a emissions from vehicles.
Siegl, W O; Wallington, T J; Guenther, M T; Henney, T; Pawlak, D; Duffy, M
2002-02-15
We report the first study of R-134a (also known as HFC-134a and CF3CFH2) refrigerant leakage from air conditioning (AC) systems of modern vehicles. Twenty-eight light duty vehicles from five manufacturers (Ford, Toyota, Daimler Chrysler, General Motors, and Honda) were tested according to the USEPA (Federal) extended diurnal test procedure using the Sealed Housing for Evaporative Determination (SHED) apparatus. All tests were conducted using stationary vehicles with the motor and air conditioning system turned off. R-134a was measured using gas chromatography (GC) with a flame ionization detector (FID). All vehicles exhibited measurable R-134a leakage over the 2-day diurnal test. Leak rates of R-134a ranged from 0.01 to 0.36 g/day with an average of 0.07+/-0.07 g/day. When combined with leakage associated with vehicle operation, servicing, and disposal we estimate that the lifetime average R-134a emission rate from an AC equipped vehicle is 0.41+/-0.27 g/day (the majority of emissions are associated with vehicle servicing and disposal). Assuming that the average vehicle travels 10 000 miles per year we estimate that the global warming impact of R-134a leakage from an AC equipped vehicle is approximately 4-5% of that of the CO2 emitted by the vehicle. The results are discussed with respect to the contribution of vehicle emissions to global climate change.
Kim, Hee Seung; Siluk, Danuta; Wainer, Irving W
2009-04-17
An on-line immunoextraction and liquid chromatography/mass spectrometry (LC/MS) method was developed and validated for the determination of R,R'-fenoterol, R,R'-methoxyfenoterol and R,S'-naphthylfenoterol in rat plasma. Sample preparation involved immunoextraction of analytes using an antibody raised against R,R'- and R,S'-aminofenoterol that was immobilized onto chromatographic support. LC was performed on a Waters hydrophilic interaction chromatography (HILIC) column (150 mm x 2.1mm), using an isocratic mobile phase of methanol:ammonium acetate (10mM, pH 6.8) (90:10, v/v) at a flow rate of 0.2 ml/min. The MS was operated in the single ion monitoring mode (m/z 304.2 for R,R'-fenoterol, m/z 318.1 for R,R'-methoxyfenoterol, and m/z 339.2 for R,S'-naphthylfenoterol). Optimization of analytes desorption process from the immunoextraction column was performed by factorial analysis and the sample calibration curves were made with spiked rat plasma samples containing 0.5-100 ng/ml of drugs. The cross-selectivity studies of the antibody were determined and the results suggested high selectivities toward R,R'-fenoterol, R,R'-methoxyfenoterol and R,S'-naphthylfenoterol. The accuracy of assay was more than 96% while intra- and inter-day precision of assay were less than 12.4%. Stability studies (2h benchtop, freeze/thaw, and autosampler stability) were conducted and the analytes were stable through out studies. The validated method was used to determine the plasma concentration-time profiles of drugs after oral administration to rats of R,R'-fenoterol, R,R'-methoxyfenoterol and R,S'-naphthylfenoterol.
The Effectiveness of Lamotrigine and Its Blood Levels for Pediatric Epilepsy.
Iwasaki, Toshiyuki; Toki, Taira; Nonoda, Yutaka; Ishii, Masahiro
This study was conducted to evaluate the effectiveness of lamotrigine (LTG) over 2 years and the usefulness of measuring its blood levels during the follow-up of patients with epilepsy. We measured peak blood LTG levels of 32 patients with epilepsy (9.16 ± 3.34 years old; mean ± SD). The blood levels were measured at 6 months, 1 year, and 2 years after reaching the LTG maintenance dosage. The effectiveness of LTG was evaluated to determine the seizure reduction rate. The patients were classified as effective cases (mean of own seizure reduction rates >50%) and ineffective cases (≤50%). The results were that the dosage and blood level showed positive correlations in the case of combination use with sodium valproate (VPA) (r = 0.690), carbamazepine and/or phenobarbital (r = 0.940), and others (r = 0.548). In several groups, the blood levels and efficacies did not show any positive correlations. In the cases of combination use with VPA, the blood levels of effective cases and ineffective cases were significantly different (P = 0.001). The optimal range was 8-11.5 μg/mL based on the average and SD values in the effective cases. No patients had any side effects. In conclusion, no precise definition of the therapeutic range was possible because of the incomplete correlation between the blood level and seizure frequency. We recommend the optimal range of LTG as a therapeutic target without any side effects, and it was established that the range in the combination with VPA was 8-11.5 μg/mL.
Youth, new media, and HIV/AIDS: determinants of participation in an online health social movement.
Vijaykumar, Santosh; Wray, Ricardo J; Buskirk, Trent; Piplani, Himakshi; Banerjee, Joya; Furdyk, Michael; Pattni, Reshma
2014-07-01
Abstract This paper focuses on the Global Youth Coalition for HIV/AIDS (GYCA), a collaboration of young people who utilize the Internet to organize and inform the global youth HIV/AIDS social movement. We used a trans-disciplinary conceptual framework guided by the diffusion of innovations approach to explore factors that influence online participation among the coalition's members and to explain perceived effects of participation. We used a randomized stratified sampling strategy to conduct an online 7 week survey of GYCA's members (n=275). Descriptive statistics revealed that the majority of participants were from Africa (∼54%) and Asia (∼24%), with an average age of 27 years. Multiple linear regression analyses showed that participation in the e-consultations (R(2)=0.39, p<0.001) was influenced by a greater number of factors compared to the listserv (R(2)=0.20, p<0.001). Online participation significantly influenced perceptions about the coalition's social networking utility (R(2)=0.21, p<0.001). Perceived social networking utility significantly explained perceived effects on program areas such as knowledge sharing (R(2)=0.49, p<0.001), capacity building (R(2)=0.48, p<0.001), and political advocacy (R(2)=0.44, p<0.001). We concluded that a range of factors shapes participation in online health social movements. Initiatives such as GYCA need regular, intensive assessments to understand these factors for better tailoring their online activities to members' needs and for greater impact.
Tamburini, Elena; Ferrari, Giuseppe; Marchetti, Maria Gabriella; Pedrini, Paola; Ferro, Sergio
2015-01-01
Agricultural practices determine the level of food production and, to great extent, the state of the global environment. During the last decades, the indiscriminate recourse to fertilizers as well as the nitrogen losses from land application have been recognized as serious issues of modern agriculture, globally contributing to nitrate pollution. The development of a reliable Near-Infra-Red Spectroscopy (NIRS)-based method, for the simultaneous monitoring of nitrogen and chlorophyll in fresh apple (Malus domestica) leaves, was investigated on a set of 133 samples, with the aim of estimating the nutritional and physiological status of trees, in real time, cheaply and non-destructively. By means of a FT (Fourier Transform)-NIR instrument, Partial Least Squares (PLS) regression models were developed, spanning a concentration range of 0.577%–0.817% for the total Kjeldahl nitrogen (TKN) content (R2 = 0.983; SEC = 0.012; SEP = 0.028), and of 1.534–2.372 mg/g for the total chlorophyll content (R2 = 0.941; SEC = 0.132; SEP = 0.162). Chlorophyll-a and chlorophyll-b contents were also evaluated (R2 = 0.913; SEC = 0.076; SEP = 0.101 and R2 = 0.899; SEC = 0.059; SEP = 0.101, respectively). All calibration models were validated by means of 47 independent samples. The NIR approach allows a rapid evaluation of the nitrogen and chlorophyll contents, and may represent a useful tool for determining nutritional and physiological status of plants, in order to allow a correction of nutrition programs during the season. PMID:25629703
Wulf, J S; Rühmann, S; Rego, I; Puhl, I; Treutter, D; Zude, M
2008-05-14
Laser-induced fluorescence spectroscopy (LIFS) was nondestructively applied on strawberries (EX = 337 nm, EM = 400-820 nm) to test the feasibility of quantitatively determining native phenolic compounds in strawberries. Eighteen phenolic compounds were identified in fruit skin by UV and MS spectroscopy and quantitatively determined by use of rp-HPLC for separation and diode-array or chemical reaction detection. Partial least-squares calibration models were built for single phenolic compounds by means of nondestructively recorded fluorescence spectra in the blue-green wavelength range using different data preprocessing methods. The direct orthogonal signal correction resulted in r (2) = 0.99 and rmsep < 8% for p-coumaroyl-glucose, and r (2) = 0.99 and rmsep < 24% for cinnamoyl-glucose. In comparison, the correction of the fluorescence spectral data with simultaneously recorded reflectance spectra did not further improve the calibration models. Results show the potential of LIFS for a rapid and nondestructive assessment of contents of p-coumaroyl-glucose and cinnamoyl-glucose in strawberry fruits.
Michelitsch, Astrid; Rittmannsberger, Anna
2003-01-01
A reliable and simple differential pulse polarographic method is described for the determination of thymoquinone in black seed oil. The polarographic behaviour of thymoquinone was examined in various buffer systems over the pH range 5.0-10.0. Thymoquinone is reduced in a single, reversible peak at the dropping mercury electrode. The differential pulse polarogram showed a distinct peak in Sörensen buffer:methanol (3:7, v/v; pH 8.5) at a peak potential of -0.095 V (vs. silver/silver chloride electrode), and a plot of peak height against concentration was found to be linear over the range 0.2-15.0 microg/mL (R = 0.9998). The limit of detection was calculated to be 0.054 microg/mL. The polarographic method has been applied to determine thymoquinone in two black seed oil preparations available on the Austrian pharmaceutical market.
Kandhro, Aftab A; Laghari, Abdul Hafeez; Mahesar, Sarfaraz A; Saleem, Rubina; Nelofar, Aisha; Khan, Salman Tariq; Sherazi, S T H
2013-11-01
A quick and reliable analytical method for the quantitative assessment of cefixime in orally administered pharmaceutical formulations is developed by using diamond cell attenuated total reflectance (ATR) Fourier transform infrared (FT-IR) spectroscopy as an easy procedure for quality control laboratories. The standards for calibration were prepared in aqueous medium ranging from 350 to 6000mg/kg. The calibration model was developed based on partial least square (PLS) using finger print region of FT-IR spectrum in the range from 1485 to 887cm(-1). Excellent coefficient of determination (R(2)) was achieved as high as 0.99976 with root mean square error of 44.8 for calibration. The application of diamond cell (smart accessory) ATR FT-IR proves a reliable determination of cefixime in pharmaceutical formulations to assess the quality of the final product. Copyright © 2013 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Keenan, F. P.; Conlon, E. S.; Rubin, R. H.
1994-10-01
Theoretical O I density-sensitive emission-line ratios R = I(2s2)(2p4)(3P0)-((2s2)(2p4)(3P1))/I((2s2)(2p4)(3P1)-(2s2)(2p4)(3P2)) = I(146 micrometers)/I(63 micrometers) are presented for a range of temperatures (T = 100-10,000 K), neutral hydrogen densities (NH = 10-2 to 107/cu cm) and radiation fields (G0 = 1-106) applicable to both photodissociation regions (PDRs) and H II regions and the diffuse ionized medium (DIM). The observed values of R for several PDRs, measured from far-infrared spectra obtained with the Kuiper Airborne Observatory (KAO), imply hydrogen densities which are in good agreement with those determined using other methods. This provides observational support for the validity of the theoretical O I line ratios, and hence the atomic data used in their derivation.
Bernaitis, Nijole; Ching, Chi Keong; Chen, Liping; Hon, Jin Shing; Teo, Siew Chong; Davey, Andrew K; Anoopkumar-Dukie, Shailendra
2017-01-01
Warfarin reduces stroke risk in atrial fibrillation (AF) patients but requires ongoing monitoring. Time in therapeutic range (TTR) is used as a measure of warfarin control, with a TTR less than 60% associated with adverse patient outcomes. The Sex, Age, Medical history, Treatment, Tobacco use, Race (SAMe-TT 2 R 2 ) score has been identified as a model able to predict warfarin control, but this has been tested in mainly Caucasian populations. Therefore, the aim of this study was to determine the ability of the SAMe-TT 2 R 2 score to predict warfarin control in a Singaporean population consisting of Chinese, Malay, and Indian race. Retrospective data were collected from the National Heart Centre Singapore for AF patients receiving warfarin between January and June 2014. The TTR and the SAMe-TT 2 R 2 score were calculated for each patient. The 1137 non-valvular AF patients had a mean TTR of 58.0 ± 34.3% and a median SAMe-TT 2 R 2 score of 3. The categorized SAMe-TT 2 R 2 scores (2 versus >2) showed a significant reduction in mean TTR for the entire population (63.2% versus 55.8%, P = .0004) and also when categorized according to race for Chinese (62.7% versus 56.9%, P = .0075) and Malay (68.4% versus 50.6%, P = .0131) populations. The SAMe-TT 2 R 2 tool is effective in predicting warfarin control in a Singaporean population as patients with a score greater than 2 had poor control. The minimum score for non-Caucasian patients is 2; thus, in these patients, the presence of any additional risk factors identified in the SAMe-TT 2 R 2 tool categorizes them as unlikely to achieve adequate warfarin control and possible candidates for alternative anticoagulants. Copyright © 2017 National Stroke Association. Published by Elsevier Inc. All rights reserved.
Relationships of physical performance tests to military-relevant tasks in women.
Szivak, Tunde K; Kraemer, William J; Nindl, Bradley C; Gotshalk, Lincoln A; Volek, Jeff S; Gomez, Ana L; Dunn-Lewis, Courtenay; Looney, David P; Comstock, Brett A; Hooper, David R; Flanagan, Shawn D; Maresh, Carl M
2014-01-01
This investigation sought to determine the most predictive measures of performance on a repetitive box lifting task (RBLT) and load bearing task (LBT) among 123 women (aged ±4 years, height 165±7 cm, body mass 64±10 kg). To determine the relationship of various predictors to performance on the RBLT and LBT, multiple regression analysis was conducted on body mass, height, leg cross-sectional area, upper and lower body muscular strength, lower body explosive power, upper and lower body local muscular endurance, and aerobic capacity. The mean±SD (range) number of repetitions for the RBLT was 86±23 (20-159). The mean±SD (range) time to complete the LBT was 2,054±340 seconds (1,307-3,447). The following equations were generated: RBLT (number of repetitions)=57.4+0.2(peak jump power)+0.4(number of pushups in 2 minutes)+0.15(number of repetitions during the squat endurance test)+1.39(one repetition maximal strength boxlift (kg))-0.04(2-mile run time (2MR) in seconds), R=0.81; standard error of the estimate (SEE)=14; LBT (in seconds)=1,831-4.28(number of repetitions during the squat endurance test)+0.95(2MR in seconds)-13.4(body mass), R=0.73; SEE=232. We found that the 2MR and squat endurance test were significant predictive factors for performance on both load carriage tasks. These data also imply that women's performance in combat-related tasks can be improved with training that targets muscular strength, power, and local muscular endurance in addition to aerobic capacity.
The relationship between balance confidence and control in individuals with Parkinson's disease
Lee, Hyo Keun; Altman, Lori J.P.; McFarland, Nikolaus; Hass, Chris J.
2016-01-01
Introduction A broad range of subjective and objective assessments have been used to assess balance confidence and balance control in persons with Parkinson's disease (PD). However, little is known about the relationship between self-perceived balance confidence and actual balance control in PD. The purpose of this investigation was to determine the relationship between self-perceived balance confidence and objectively measured static/dynamic balance control abilities. Methods Forty-four individuals with PD participated in the study. Patients were stratified into 2 groups based on the modified Hoehn and Yahr (H&Y) disability score: early stage, H&Y≤2.0 and moderate stage, H&Y ≥2.5. All participants completed the activities-specific balance confidence (ABC) scale and performed standing balance and gait initiation tasks to assess static and dynamic balance control. The center of pressure (COP) sway (CE95%Sway) during static balance and the peak distance between the projections of the COP and the center of mass (COM) in the transverse plane (COPCOM) during gait initiation were calculated. Pearson correlation analyses were conducted relating the ABC score and CE95%Sway and COPCOM. Results For early stage PD, there was a moderate correlation between ABC score and CE95 %Sway (r=-0.56, R2=0.32, p=0.002), while no significant correlation was found between ABC score and COPCOM (r=-0.24, R2=0.06, p=0.227). For moderate stage PD, there was a moderate correlation between ABC score and COPCOM (r=0.49, R2=0.24, p=0.044), while no correlation was found between ABC score and CE95%Sway (r=-0.19, R2=0.04, p=0.478). Conclusion Individuals with different disease severities showed different relationships between balance confidence and actual static/dynamic balance control. PMID:26949065
Changes of Linearity in MF2 Index with R12 and Solar Activity Maximum
NASA Astrophysics Data System (ADS)
Villanueva, L.
2013-05-01
Critical frequency of F2 layer is related to the solar activity, and the sunspot number has been the standard index for ionospheric prediction programs. This layer, being considered the most important in HF radio communications due to its highest electron density, determines the maximum frequency coming back from ground base transmitter signals, and shows irregular variation in time and space. Nowadays the spatial variation, better understood due to the availability of TEC measurements, let Space Weather Centers have observations almost in real time. However, it is still the most difficult layer to predict in time. Short time variations are improved in IRI model, but long term predictions are only related to the well-known CCIR and URSI coefficients and Solar activity R12 predictions, (or ionospheric indexes in regional models). The concept of the "saturation" of the ionosphere is based on data observations around 3 solar cycles before 1970, (NBS, 1968). There is a linear relationship among MUF (0Km) and R12, for smooth Sunspot numbers R12 less than 100, but constant for higher R12, so, no rise of MUF is expected for R12 higher than 100. This recommendation has been used in most of the known Ionospheric prediction programs for HF Radio communication. In this work, observations of smoothed ionospheric index MF2 related to R12 are presented to find common features of the linear relationship, which is found to persist in different ranges of R12 depending on the specific maximum level of each solar cycle. In the analysis of individual solar cycles, the lapse of linearity is less than 100 for a low solar cycle and higher than 100 for a high solar cycle. To improve ionospheric predictions we can establish levels for solar cycle maximum sunspot numbers R12 around low 100, medium 150 and high 200 and specify the ranges of linearity of MUF(0Km) related to R12 which is not only 100 as assumed for all the solar cycles. For lower levels of solar cycle, discussions of present observations are presented.
Zornoza, R; Guerrero, C; Mataix-Solera, J; Scow, K M; Arcenegui, V; Mataix-Beneyto, J
2008-07-01
The potential of near infrared (NIR) reflectance spectroscopy to predict various physical, chemical and biochemical properties in Mediterranean soils from SE Spain was evaluated. Soil samples (n=393) were obtained by sampling thirteen locations during three years (2003-2005 period). These samples had a wide range of soil characteristics due to variations in land use, vegetation cover and specific climatic conditions. Biochemical properties also included microbial biomarkers based on phospholipid fatty acids (PLFA). Partial least squares (PLS) regression with cross validation was used to establish relationships between the NIR spectra and the reference data from physical, chemical and biochemical analyses. Based on the values of coefficient of determination (r(2)) and the ratio of standard deviation of validation set to root mean square error of cross validation (RPD), predicted results were evaluated as excellent (r(2)>0.90 and RPD>3) for soil organic carbon, Kjeldahl nitrogen, soil moisture, cation exchange capacity, microbial biomass carbon, basal soil respiration, acid phosphatase activity, β-glucosidase activity and PLFA biomarkers for total bacteria, Gram positive bacteria, actinomycetes, vesicular-arbuscular mycorrhizal fungi and total PLFA biomass. Good predictions (0.81
Norman, Jane E; Lee, Kurtis R; Walker, Mary E; Murden, Sherina L; Harris, Jessica; Mundell, Stuart; J Murphy, Gavin; Mumford, Andrew D
2015-10-01
Multiple electrode aggregometry (MEA) improves prediction of thrombosis and bleeding in cardiac patients. However, the causes of inter-individual variation in MEA results are incompletely understood. We explore whether low MEA results are associated with platelet G-protein coupled receptor (GPCR) gene variants. The effects of P2Y12 receptor (P2Y12), thromboxane A2 receptor (TPα) and protease-activated receptor 1 (PAR1) dysfunction on the MEA ADP-test, ASPI-test and TRAP-test were determined using receptor antagonists. Cardiac surgery patients with pre-operative MEA results suggesting GPCR dysfunction were selected for P2Y12 (P2RY12), TPα (TBXA2R) and PAR1 (F2R) sequencing. In control blood samples, P2Y12, TPα or PAR1 antagonists markedly reduced ADP-test, ASPI-test and TRAP-test results respectively. In the 636 patients from a cohort of 2388 cardiac surgery patients who were not receiving aspirin or a P2Y12 blocker, the median ADP-test result was 75.1 U (range 4.8-153.2), ASPI-test 83.7 U (1.4-157.3) and TRAP-test 117.7 U (2.4-194.1), indicating a broad range of results unexplained by anti-platelet drugs. In 238 consenting patients with unexplained low MEA results, three P2RY12 variants occurred in 70/107 (65%) with suspected P2Y12 dysfunction and four TBXA2R variants occurred in 19/22 (86%) with suspected TPα dysfunction although the later group was too small to draw meaningful conclusions about variant frequency. All the variants were synonymous and unlikely to cause GPCR dysfunction. There were no F2R variants in the 109 cases with suspected PAR1 dysfunction. MEA results suggesting isolated platelet GPCR dysfunction were common in cardiac surgery patients, but were not associated with non-synonymous variants in P2RY12 or F2R. Copyright © 2015 Elsevier Ltd. All rights reserved.
Pinkas, Jiří; Gyepes, Róbert; Císařová, Ivana; Kubišta, Jiří; Horáček, Michal; Mach, Karel
2015-04-28
The titanocene-ethene complex [Ti(II)(η(2)-C2H4)(η(5)-C5Me5)2] (1) with simple internal alkynes R(1)C≡CR(2) gives complexes [Ti(II)(η(2)-R(1)C≡CR(2))(η(5)-C5Me5)2] {R(1), R(2): Ph, Ph (3), Ph, Me (4), Me, SiMe3 (5), Ph, SiMe3 (6), t-Bu, SiMe3 (7), and SiMe3, SiMe3 (8). In contrast, alkynes with R(1) = Me and R(2) = t-Bu or i-Pr afford allene complexes [Ti(II)(η(2)-CH2=C=CHR(2))(η(5)-C5Me5)2] (11) and (12), whereas for R(2) = Et a mixture of alkyne complex (13A) and minor allene (13) is obtained. Crystal structures of 4, 6, 7 and 11 have been determined; the latter structure proved the back-bonding interaction of the allene terminal double bond. Only the synthesis of 8 from 1 was inefficient because the equilibrium constant for the reaction [1] + [Me3SiC≡CSiMe3] ⇌ [8] + [C2H4] approached 1. Compound 9 (R(1), R(2): Me), not obtainable from 1, together with compounds 3–6 and 10 (R(1), R(2): Et) were also prepared by alkyne exchange with 8, however this reaction did not take place in attempts to obtain 7. Compounds 1 and 3–9 display the longest-wavelength electronic absorption band in the range 670-940 nm due to the HOMO → LUMO transition. The assignment of the first excitation to be of predominantly a b2 → a1 transition was confirmed by DFT calculations. The calculated first excitation energies for 3–9 followed the order of hypsochromic shifts of the absorption band relative to 8 that were induced by acetylene substituents: Me > Ph ≫ SiMe3. Computational results have also affirmed the back-bonding nature in the alkyne-to-metal coordination.
Spink, Barbara C.; Bennett, James A.; Pentecost, Brian T.; Lostritto, Nicole; Englert, Neal A.; Benn, Geoffrey K.; Goodenough, Angela K.; Turesky, Robert J.; Spink, David C.
2009-01-01
The cumulative exposure to estrogens is an important determinant in the risk of breast cancer, yet the full range of mechanisms involving estrogens in the genesis and progression of breast cancer remains a subject of debate. Interactions of estrogens and environmental toxicants have received attention as putative factors contributing to carcinogenesis. Mechanistic studies have demonstrated interactions between estrogen receptor α (ERα) and the aryl hydrocarbon receptor (AhR), with consequences on the genes that they regulate. Many studies of ERα and AhR-mediated effects and crosstalk between them have focused on the initial molecular events. In this study, we investigated ERα- and AhR-mediated effects in long-term estrogen exposed (LTEE) MCF-7 human breast cancer cells, which were obtained by continuous culturing for at least 12 weeks in medium supplemented with 1 nM of 17β-estradiol (E2). With these LTEE cells and with parallel control cells cultured without E2 supplementation, we performed an extensive study of cytochrome P450 (CYP) induction, carcinogen bioactivation, global gene expression, and tumorigenicity in immunocompromised mice. We found that LTEE cells, in comparison with control cells, had higher levels of AhR mRNA and protein, greater responsiveness for AhR-regulated CYP1A1 and CYP1B1 induction, a 6-fold higher initial level of benzo(a)pyrene-DNA adducts as determined by liquid chromatography tandem mass spectrometry, marked differences in the expression of numerous genes, and a higher rate of E2-dependent tumor growth as xenografts. These studies indicate that LTEE causes adaptive responses in MCF-7 cells, which may reflect processes that contribute to the overall carcinogenic effect of E2. PMID:19619570
Fatigue loading and R-curve behavior of a dental glass-ceramic with multiple flaw distributions.
Joshi, Gaurav V; Duan, Yuanyuan; Della Bona, Alvaro; Hill, Thomas J; St John, Kenneth; Griggs, Jason A
2013-11-01
To determine the effects of surface finish and mechanical loading on the rising toughness curve (R-curve) behavior of a fluorapatite glass-ceramic (IPS e.max ZirPress) and to determine a statistical model for fitting fatigue lifetime data with multiple flaw distributions. Rectangular beam specimens were fabricated by pressing. Two groups of specimens (n=30) with polished (15 μm) or air abraded surface were tested under rapid monotonic loading in oil. Additional polished specimens were subjected to cyclic loading at 2 Hz (n=44) and 10 Hz (n=36). All fatigue tests were performed using a fully articulated four-point flexure fixture in 37°C water. Fractography was used to determine the critical flaw size and estimate fracture toughness. To prove the presence of R-curve behavior, non-linear regression was used. Forward stepwise regression was performed to determine the effects on fracture toughness of different variables, such as initial flaw type, critical flaw size, critical flaw eccentricity, cycling frequency, peak load, and number of cycles. Fatigue lifetime data were fit to an exclusive flaw model. There was an increase in fracture toughness values with increasing critical flaw size for both loading methods (rapid monotonic loading and fatigue). The values for the fracture toughness ranged from 0.75 to 1.1 MPam(1/2) reaching a plateau at different critical flaw sizes based on loading method. Cyclic loading had a significant effect on the R-curve behavior. The fatigue lifetime distribution was dependent on the flaw distribution, and it fit well to an exclusive flaw model. Copyright © 2013 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Fatigue loading and R-curve behavior of a dental glass-ceramic with multiple flaw distributions
Joshi, Gaurav V.; Duan, Yuanyuan; Bona, Alvaro Della; Hill, Thomas J.; John, Kenneth St.; Griggs, Jason A.
2013-01-01
Objectives To determine the effects of surface finish and mechanical loading on the rising toughness curve (R-curve) behavior of a fluorapatite glass-ceramic (IPS e.max ZirPress) and to determine a statistical model for fitting fatigue lifetime data with multiple flaw distributions. Materials and Methods Rectangular beam specimens were fabricated by pressing. Two groups of specimens (n=30) with polished (15 μm) or air abraded surface were tested under rapid monotonic loading in oil. Additional polished specimens were subjected to cyclic loading at 2 Hz (n=44) and 10 Hz (n=36). All fatigue tests were performed using a fully articulated four-point flexure fixture in 37°C water. Fractography was used to determine the critical flaw size and estimate fracture toughness. To prove the presence of R-curve behavior, non-linear regression was used. Forward stepwise regression was performed to determine the effects on fracture toughness of different variables, such as initial flaw type, critical flaw size, critical flaw eccentricity, cycling frequency, peak load, and number of cycles. Fatigue lifetime data were fit to an exclusive flaw model. Results There was an increase in fracture toughness values with increasing critical flaw size for both loading methods (rapid monotonic loading and fatigue). The values for the fracture toughness ranged from 0.75 to 1.1 MPa·m1/2 reaching a plateau at different critical flaw sizes based on loading method. Significance Cyclic loading had a significant effect on the R-curve behavior. The fatigue lifetime distribution was dependent on the flaw distribution, and it fit well to an exclusive flaw model. PMID:24034441
de Vreede, Paul L; Samson, Monique M; van Meeteren, Nico L; Duursma, Sijmen A; Verhaar, Harald J
2006-08-01
The Assessment of Daily Activity Performance (ADAP) test was developed, and modeled after the Continuous-scale Physical Functional Performance (CS-PFP) test, to provide a quantitative assessment of older adults' physical functional performance. The aim of this study was to determine the intra-examiner reliability and construct validity of the ADAP in a community-living older population, and to identify the importance of tester experience. Forty-three community-dwelling, older women (mean age 75 yr +/-4.3) were randomized to the test-retest reliability study (n=19) or validation study (n=24). The intra-examiner reliability of an experienced (tester 1) and an inexperienced tester (tester 2) was assessed by comparing test and retest scores of 19 participants. Construct validity was assessed by comparing the ADAP scores of 24 participants with self-perceived function by the SF-36 Health Survey, muscle function tests, and the Timed Up and Go test (TUG). Tester 1 had good consistency and reliability scores (mean difference between test and retest scores (DIF), -1.05+/-1.99; 95% confidence interval (CI), -2.58 to 0.48; Cronbach's alpha (alpha) range, 0.83 to 0.98; intraclass correlation (ICC) range, 0.75 to 0.96; Limits of Agreement (LoA), -2.58 to 4.95). Tester 2 had lower reliability scores (DIF, -2.45+/-4.36; 95% CI, -5.56 to 0.67; alpha range, 0.53 to 0.94; ICC range, 0.36 to 0.90; LoA, -6.09 to 10.99), with a systematic difference between test and retest scores for the ADAP domain lower-body strength (-3.81; 95% CI, -6.09 to -1.54), ADAP correlated with SF-36 Physical Functioning scale (r=0.67), TUG test (r=-0.91) and with isometric knee extensor strength (r=0.80). The ADAP test is a reliable and valid instrument. Our results suggest that testers should practise using the test, to improve reliability, before applying it to clinical settings.
Validation of a spectrophotometric assay method for bisoprolol using picric acid.
Panainte, Alina-Diana; Bibire, Nela; Tântaru, Gladiola; Apostu, M; Vieriu, Mădălina
2013-01-01
Bisoprolol is a drug belonging to beta blockers drugs used primarily for the treatment of cardiovascular diseases. A spectrophotometric method for quantitative determination of bisoprolol was developed based on the formation of a complex combination between bisoprolol and picric acid. The complex combination of bisoprolol and picric acid has a maximum absorbance peak at 420 nm. Optimum working conditions were established and the method was validated. The method presented a good linearity in the concentration range 5-120 microg/ml (regression coefficient r2 = 0.9992). The RSD for the precision of the method was 1.74 and for the intermediate precision 1.43, and recovery values ranged between 98.25-101.48%. The proposed and validated spectrophotometric method for the determination of bisoprolol is simple and cost effective.
Naing, Nyi Nyi; Li, Sam Fong Yau; Lee, Hian Kee
2016-01-04
A facile method of extraction using porous membrane protected micro-solid phase extraction (μ-SPE) with a graphene-based sorbent followed by high performance liquid chromatography-ultraviolet detector was developed. The reduced graphene oxide (r-GO) (1mg), synthesized from graphite oxide, was enclosed in a polypropylene bag representing the μ-SPE device, which was used for the extraction of estrogens such as estrone, 17β-estradiol, 17α-ethynylestradiol and diethylstilbestrol in water. The r-GO obtained was identified and characterized by Fourier transform infrared, transmission electron microscopy, scanning electron microscopy and thermogravimetric analysis. The sorbent was loaded with sodium dodecyl sulfate by sonication to prevent agglomeration in aqueous solution. With this method, low limits of detection of between 0.24 and 0.52 ng L(-1) were achieved. For estrogen analysis a linear calibration range of 0.01-100 μg L(-1) was obtained, with the coefficients of determination (r(2)) higher than 0.992. This proposed method was successfully applied to determine estrogens in water. Copyright © 2015 Elsevier B.V. All rights reserved.
Alarfaj, Nawal A; El-Tohamy, Maha F
2015-12-01
Two novel sensitive sequential injection chemiluminescence analysis and fluorescence methods for trovafloxacin mesylate detection have been developed. The methods were based on the enhancement effect of gold nanoparticles on luminol-ferricyanide-trovafloxacin and europium(III)-trovafloxacin complex systems. The optimum conditions for both detection methods were investigated. The chemiluminescence signal was emitted due to the enhanced effect of gold nanoparticles on the reaction of luminol-ferricyanide-trovafloxacin in an alkaline medium. The response was linear over a concentration range of 1.0 × 10(-9) to 1.0 × 10(-2) mol/L (%RSD = 1.3), (n = 9, r = 0.9991) with a detection limit of 1.7 × 10(-10) mol/L (S/N = 3). The weak fluorescence intensity signal of the oxidation complex of europium(III)-trovafloxacin was strongly enhanced by gold nanoparticles and detected at λex = 330 and λem = 540 nm. Fluorescence detection enabled the determination of trovafloxacin mesylate over a linear range of 1.0 × 10(-8) to 1.0 × 10(-3) mol/L (%RSD = 1.2), (n = 6, r = 0.9993) with a detection limit of 3.3 × 10(-9) mol/L. The proposed methods were successfully applied to the determination of the studied drug in its bulk form and in pharmaceutical preparations. The results were treated statistically and compared with those obtained from other reported methods. Copyright © 2015 John Wiley & Sons, Ltd.
Pauling bond strength, bond length and electron density distribution
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gibbs, Gerald V.; Ross, Nancy L.; Cox, David F.
2014-01-18
A power law regression equation, = 1.46(/r)-0.19, connecting the average experimental bond lengths, , with the average accumulation of the electron density at the bond critical point, , between bonded metal M and oxygen atoms, determined at ambient conditions for oxide crystals, where r is the row number of the M atom, is similar to the regression equation R(M-O) = 1.39(ρ(rc)/r)-0.21 determined for three perovskite crystals for pressures as high as 80 GPa. The two equations are also comparable with those, = 1.43( /r)-0.21, determined for a large number of oxide crystals at ambient conditions and = 1.39(/r)-0.22, determined formore » geometry optimized hydroxyacid molecules, that connect the bond lengths to the average Pauling electrostatic bond strength, , for the M-O bonded interactions. On the basis of the correspondence between the two sets of equations connecting ρ(rc) and the Pauling bond strength s with bond length, it appears that Pauling’s simple definition of bond strength closely mimics the accumulation of the electron density between bonded pairs of atoms. The similarity of the expressions for the crystals and molecules is compelling evidence that the M-O bonded interactions for the crystals and molecules 2 containing the same bonded interactions are comparable. Similar expressions, connecting bond lengths and bond strength, have also been found to hold for fluoride, nitride and sulfide molecules and crystals. The Brown-Shannon bond valence, σ, power law expression σ = [R1/(R(M-O)]N that has found wide use in crystal chemistry, is shown to be connected to a more universal expression determined for oxides and the perovskites, = r[(1.41)/]4.76, demonstrating that the bond valence for a bonded interaction is likewise closely connected to the accumulation of the electron density between the bonded atoms. Unlike the Brown-Shannon expression, it is universal in that it holds for the M-O bonded interactions for a relatively wide range of M atoms of the periodic table. The power law equation determined for the oxide crystals at ambient conditions is similar to the power law expression = r[1.46/]5.26 determined for the perovskites at pressures as high as 80 GPa, indicating that the intrinsic connection between R(M-O) and ρ(rc) that holds at ambient conditions also holds, to a first approximation, at high pressures.« less
Yan, Wenwu; Wang, Nani; Zhang, Peimin; Zhang, Jiajie; Wu, Shuchao; Zhu, Yan
2016-08-01
Sucralose is widely used in food and beverages as sweetener. Current synthesis approaches typically provide sucralose products with varying levels of related chlorinated carbohydrates which can affect the taste and flavor-modifying properties of sucralose. Quantification of related compounds in sucralose is often hampered by the lack of commercially available standards. In this work, nine related compounds were purified (purity>97%) and identified by liquid chromatography-mass spectrometry (LC-MS) and nuclear magnetic resonance (NMR), then a rapid and simple HPLC coupled with evaporative light scattering detection (ELSD) method has been developed for the simultaneous determination of sucralose and related compounds. Under optimized conditions, the method showed good linearity in the range of 2-600μgmL(-1) with determination coefficients R(2)⩾0.9990. Moreover, low limits of detection in the range of 0.5-2.0μgmL(-1) and good repeatability (RSD<3%, n=6) were obtained. Recoveries were from 96.8% to 101.2%. Finally, the method has been successfully applied to sucralose quality control and purification process monitoring. Copyright © 2016 Elsevier Ltd. All rights reserved.
Defining the determinants of endurance running performance in the heat
James, Carl A.; Hayes, Mark; Willmott, Ashley G. B.; Gibson, Oliver R.; Schlader, Zachary J.; Maxwell, Neil S.
2017-01-01
ABSTRACT In cool conditions, physiologic markers accurately predict endurance performance, but it is unclear whether thermal strain and perceived thermal strain modify the strength of these relationships. This study examined the relationships between traditional determinants of endurance performance and time to complete a 5-km time trial in the heat. Seventeen club runners completed graded exercise tests (GXT) in hot (GXTHOT; 32°C, 60% RH, 27.2°C WBGT) and cool conditions (GXTCOOL; 13°C, 50% RH, 9.3°C WBGT) to determine maximal oxygen uptake (V̇O2max), running economy (RE), velocity at V̇O2max (vV̇O2max), and running speeds corresponding to the lactate threshold (LT, 2 mmol.l−1) and lactate turnpoint (LTP, 4 mmol.l−1). Simultaneous multiple linear regression was used to predict 5 km time, using these determinants, indicating neither GXTHOT (R2 = 0.72) nor GXTCOOL (R2 = 0.86) predicted performance in the heat as strongly has previously been reported in cool conditions. vV̇O2max was the strongest individual predictor of performance, both when assessed in GXTHOT (r = −0.83) and GXTCOOL (r = −0.90). The GXTs revealed the following correlations for individual predictors in GXTHOT; V̇O2max r = −0.7, RE r = 0.36, LT r = −0.77, LTP r = −0.78 and in GXTCOOL; V̇O2max r = −0.67, RE r = 0.62, LT r = −0.79, LTP r = −0.8. These data indicate (i) GXTHOT does not predict 5 km running performance in the heat as strongly as a GXTCOOL, (ii) as in cool conditions, vV̇O2max may best predict running performance in the heat. PMID:28944273
An, Jianguo; Sun, Mingjiang; Bai, Lin; Chen, Ted; Liu, David Q; Kord, Alireza
2008-11-04
Derivatization LC/MS methodology has been developed for the determination of a group of commonly encountered alkyl esters of sulfonates or sulfates in drug substances at low ppm levels. This general method uses trimethylamine as the derivatizing reagent for ethyl/propyl/isopropyl esters and triethylamine for methyl esters. The resulting quaternary ammonium derivatization products are highly polar (ionic) and can be retained by a hydrophilic interaction liquid chromatography (HILIC) column and readily separated from the main interfering active pharmaceutical ingredient (API) peak that is usually present at very high concentration. The method gives excellent sensitivity for all the alkyl esters at typical target analyte level of 1-2 ppm when the API samples were prepared at 5mg/mL. The recoveries at 1-2 ppm were generally above 85% for all the alkyl esters in the various APIs tested. The injection precisions of the lowest concentration standards were excellent with R.S.D.=0.4-4%. A linear range for concentrations from 0.2 to 20 ppm has been established with R(2)>or=0.99. This general method has been tested in a number of API matrices and used successfully for determination of alkyl sulfonates or dialkyl sulfates in support of API batch releases at GlaxoSmithKline.
[Spectrophotometric determination of piroxicam using ferric ferricyanide as reagent].
Mândrescu, Mariana; Spac, A F; Dorneanu, V
2009-01-01
For the piroxicam determination (nonsteroidal antiinflammatory drug-NSAID) it was developed a spectrophotometric method, based on the reduction of ferric ferricyanide into ferro-ferricyanide (Prussian Blue), with maximum of absorbance at 760 nm. The practical working conditions were established. In the 0.2 divided by 2.0 microg/mL range of piroxicam concentration, were used the 2 mL of ferric ferricyanide 1 mL of 2N hydrocloric acid. To delay the flocculation of Prussian Blue it was to add a 1 mL solution of sodium lauryl sulfate 1%. After 15 minutes read the absorbance at 760 nm. The developed method was validated. The method showed a good linearity in the range of 0.2 divided by 2.0 microg/mL (the correlation coefficient r = 0.9995). The detection limit (LD) was 0.056 microg/mL and the quantification limit (LQ) was 0.18 microg/mL. There were established the system precision (RSD = 0.25%), the precison (RSD = 1.91%) and the accuracy-recovery in the range 98.21 divided by 104.92% with a mean recovery of 100.91%. The experimental results demonstrated a good sensibility. The specific absorptivity for this method is A(1 cm, 760 nm)(1%) = 4374 much higher than piroxicam in UV (A(1 cm, 330 nm)(1%) = 296)
General probability-matched relations between radar reflectivity and rain rate
NASA Technical Reports Server (NTRS)
Rosenfeld, Daniel; Wolff, David B.; Atlas, David
1993-01-01
An improved method for transforming radar-observed reflectivities Ze into rain rate R is presented. The method is based on a formulation of a Ze-R function constrained such that (1) the radar-retrieved pdf of R and all of its moments are identical to those determined from the gauges over a sufficiently large domain, and (2) the fraction of the time that it is raining above a low but still has an accurately measurable rain intensity is identical for both the radar and for simultaneous measurements of collocated gauges on average. Data measured by a 1.65-deg beamwidth C-band radar and 22 gauges located in the vicinity of Darwin, Australia, are used. The resultant Ze-R functions show a strong range dependence, especially for the rain regimes characterized by strong reflectivity gradients and substantial attenuation. The application of these novel Ze-R functions to the radar data produces excellent matches to the gauge measurements without any systematic bias.
Soliman, Suzan Mahmoud
2012-01-01
A novel economic procedure for the simultaneous stereospecific separation and analysis of (R)- and (S)-citalopram and its related substances or impurities has been developed and validated. Chromatography was performed on silica gel 60 F254 plates with acetonitrile: methanol: water (15:2.5:2.5: v/v/v) as a mobile phase containing 1.5 mM norvancomycin or 2.5 mM vancomycin as a selector at ambient temperature. (R)- and (S)-citalopram enantiomers in presence of its related substances; citalopram citadiol and citalopram N-oxide were well separated with significant Rf values of 0.33 ± 0.02, 0.85 ± 0.02, 0.45 ± 0.02 and 0.22 ± 0.02, respectively. The spots were detected with either iodine vapor, or by use of a UV lamp followed by densitometric measurement at 239 nm. All variables affecting the resolution, such as concentration of chiral selectors, mobile phase system at different temperatures and pH-values were investigated and the conditions were optimized. Calibration plots for analysis of (R)- and (S)-enantiomers were linear in the range of 0.2-16.8 μg/10 μl (R≥0.9994, n=6) with acceptable precision (%RSD<2.0) and accuracy (99.70 ± 0.85% and 99.51 ± 0.61% for (S)-citalopram and escitalopram, respectively). The limit of detection and quantification were 0.08 μg/10 μl and 0.25 μg/10 μl, respectively, for (R)- and (S)-citalopram. The proposed method is simple, selective, and robust and can be applied for quantitative determination of enantiomeric purity of (R)- and (S)-citalopram (escitalopram) as well as the related impurities in drug substances and pharmaceutical preparations. The method can be useful to investigate adulteration of pure isomer with the cheep racemic form. PMID:23675256
NASA Astrophysics Data System (ADS)
Giraud, E.
A sample of dwarf and spiral galaxies with extended rotation curves is analysed, assuming that the fraction of dark matter is small. The objective of the paper is to prepare a framework for a theory, based on fundamental principles, that would give fits of the same quality as the phenomenology of dark halos. The following results are obtained: 1) The geodesics of massive systems with low density (Class I galaxies) can be described by the metric ds^2 = b^{-1}(r)dr^2 - b(r)dt^2 + r^2 dOmega^2 where b(r) = 1 - {2 over c^2}({{GM} over r} + gamma_f M^{1/2}) In this expression Gamma_f is a new fundamental constant which has been deduced from rotation curves of galaxies with circular velocity V_c^2 >= 2 {{GM} over r} for all r 2) The above metric is deduced from the conformal invariant metric ds^2 = B^{-1}(r)dr^2 - B(r)dt^2 + r^2 dOmega^2 where B(r) = 1 - {2 over c^2}({{GM} over r} + Gamma_f M^{1/2} + {1 over 3} {Gamma_f^2 over G}r) through a linear transform, u, of the linear special group SL(2, R) 3) The term {2 over c^2}Gamma_f M^{1/2} accounts for the difference between the observed rotation velocity and the Newtonian velocity. The term {2 over {3c^2}}{Gamma_f^2 over G}r is interpreted as a scale invariance between systems of different masses and sizes. 4) The metric B is a vacuum solution around a mass M deduced from the least action principle applied to the unique action I_a = -2 a int (-g)^{1/2} [R_{mu kappa}R^{ mu kappa} - 1/3(Ralphaalpha)^2] dx^4 built with the conformal Weyl tensor 5) For galaxies such that there is a radius, r_0, at which {{GM} over r_0} = Gamma M^{1/2} (Class II), the term Gamma M^{1/2} might be confined by the Newtonian potential yielding stationary solutions. 6) The analysed rotation curves of Class II galaxies are indeed well described with metrics of the form b(r) = 1 - {2 over c^2}({{GM} over r} + (n + 1) Gamma_0 M^{1/2}) where n is an integer and Gamma_0 = {1 over the square root of 3}Gamma_f 7) The effective potential is determined and found to be E(Gamma, r) = {Gamma^2 over G}r 8) A quantized model is deduced from a Schrodinger-type equation - {{D^2} {{d^2 Psi(r)} over {dr^2}}} = {[E - {{G M} over r}] Psi(r)} where D^2 is the product of the energy Gamma M^{1/2} by the square of the radius r where {{G M} over r} = {Gamma_f M^{1/2}}. The boundary conditions are given by Psi (0) = 0 and the effective potential 9) The data are in agreement with the hypothesis of quantization, but that hypothesis is not proved because, the mass-to-light ratio being a ''free'' variable, it is always possible to shift a Gamma-curve out of its best ''energy level''. However, if one moves a Gamma-fit from an ''energy level'' to the next, the fitting of the curve becomes clearly poorer. 10) The Newtonian mass-to-light ratios of Class I galaxies range from ~7 to ~75. The mass-to-light ratios of the same objects deduced from the Gamma-dynamics are reduced to 1.1 <= Mdyn/L <= 7.4. For Class II galaxies, the range of the Newtonian mass-to-light ratios of the sample is 10 <= M_{lum+dark}^N/L <= 40. It is reduced to 1.7 <= Mdyn/L <= 4.2 when using the quantized version of the Gamma-dynamics. It is approximately 3.5 M_odot/L_odot for Sb galaxies and 2 M_odot/L_odot for Sc galaxies. 11) None of the Gamma-fits are poorer than the models with dark halos of the reference articles. The Gamma-dynamics is sensitive to the integrated mass through the term Gamma M^{1/2}, and to the mass and density through the Newtonian term {G M} over r. This kind of coupling is particularly efficient in galaxies like NGC 1560 whose rotation curve shows conspicuous structure.
Meghrous, Jamal; Khramtsov, Nikolai; Buckland, Barry C; Cox, Manon M J; Palomares, Laura A; Srivastava, Indresh K
2015-11-01
Dissolved carbon dioxide (dCO2 ) accumulation during cell culture has been recognized as an important parameter that needs to be controlled for successful scale-up of animal cell culture because above a certain concentration there are adverse effects on cell growth performance and protein production. We investigated the effect of accumulation of dCO2 in bioreactor cultures of expresSF+(®) insect cells infected with recombinant baculoviruses expressing recombinant influenza virus hemagglutinins (rHA). Different strategies for bioreactor cultures were used to obtain various ranges of concentrations of dCO2 (<50, 50-100, 100-200, and >200 mmHg) and to determine their effects on recombinant protein production and cell metabolic activity. We show that the accumulation of dCO2 at levels > 100 mmHg resulted in reduced metabolic activity, slowed cell growth, prolonged culture viability after infection, and decreased infection kinetics. The reduced rHA yields were not caused by the decrease in the extracellular pH that resulted from dCO2 accumulation, but were most likely due to the effect of dCO2 accumulation in cells. The results obtained here at the 2 L scale have been used for the design of large-scale processes to manufacture the rHA based recombinant vaccine Flublok™ at the 2500 L scale Biotechnol. Bioeng. 2015;112: 2267-2275. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.
Incomplete Ionization of a 110 meV Unintentional Donor in β-Ga2O3 and its Effect on Power Devices.
Neal, Adam T; Mou, Shin; Lopez, Roberto; Li, Jian V; Thomson, Darren B; Chabak, Kelson D; Jessen, Gregg H
2017-10-16
Understanding the origin of unintentional doping in Ga 2 O 3 is key to increasing breakdown voltages of Ga 2 O 3 based power devices. Therefore, transport and capacitance spectroscopy studies have been performed to better understand the origin of unintentional doping in Ga 2 O 3 . Previously unobserved unintentional donors in commercially available [Formula: see text] Ga 2 O 3 substrates have been electrically characterized via temperature dependent Hall effect measurements up to 1000 K and found to have a donor energy of 110 meV. The existence of the unintentional donor is confirmed by temperature dependent admittance spectroscopy, with an activation energy of 131 meV determined via that technique, in agreement with Hall effect measurements. With the concentration of this donor determined to be in the mid to high 10 16 cm -3 range, elimination of this donor from the drift layer of Ga 2 O 3 power electronics devices will be key to pushing the limits of device performance. Indeed, analytical assessment of the specific on-resistance (R onsp ) and breakdown voltage of Schottky diodes containing the 110 meV donor indicates that incomplete ionization increases R onsp and decreases breakdown voltage as compared to Ga 2 O 3 Schottky diodes containing only the shallow donor. The reduced performance due to incomplete ionization occurs in addition to the usual tradeoff between R onsp and breakdown voltage.
Compressed and saturated liquid densities for 18 halogenated organic compounds
DOE Office of Scientific and Technical Information (OSTI.GOV)
Defibaugh, D.R.; Moldover, M.R.
1997-01-01
The pressure-density-temperature P({rho},T) behavior of 18 liquids that are potential working fluids in thermal machinery has been measured using a vibrating tube densimeter. For each liquid, the data were taken on isotherms spaced at intervals of 5 K to 10 K spanning the temperature range 245 K to 370 K. The pressures ranged from just above the vapor pressure (or the critical pressure) to 6500 kPa. The results of measurements at more than 12,000 thermodynamic points are summarized by correlating functions. Comparison with data from other laboratories indicates that the relative expanded uncertainty in the measured densities is less thanmore » 0.05%, except in the critical region. The repeatability of the vapor pressure to obtain the density of the liquid at the vapor pressure. The fluids studied (and their designations by the refrigeration industry) were trichlorofluoromethane (R11), chlorodifluoromethane (R22), 1,1-dichloro-2,2,2-trifluoroethane (R123), 1,2-dichloro-1,2,2-trifluoroethane (R123a), 1-chloro-1,2,2,2-tetrafluoroethane (R124), 1,1,2,2-tetrafluoroethane (R134), 1,1,1,2-tetrafluoroethane (R134a), 1,1-dichloro-1-fluoroethane (R141b), 1,1,1-trifluoroethane (R143), 1,1,2-trifluoroethane (R143a), pentafluorodimethyl ether (E125), 1,1-difluoroethane (R152a), octafluoropropane (R218), 1,1,1,2,3,3,3-heptafluoropropane (R227ea), 2-(difluoromethoxy)-1,1,1-trifluoroethane (E245), 1,1,1,2,2-pentafluoropropane (R245cb), 1,1,1,3,3-pentafluoropropane (R245fa), and propane (R290).« less
Luedtke, Brandon E; Bosilevac, Joseph M
2015-01-01
The increased association of enterohemorrhagic Escherichia coli (EHEC) with veal calves has led the United States Department of Agriculture Food Safety and Inspection Service to report results of veal meat contaminated with the Top 7 serogroups separately from beef cattle. However, detection methods that can also provide concentration for determining the prevalence and abundance of EHEC associated with veal are lacking. Here we compared the ability of qPCR and a molecular based most probable number assay (MPN) to detect and enumerate EHEC from veal hides at the abattoir and the resulting pre-intervention carcasses. In addition, digital PCR (dPCR) was used to analyze select samples. The qPCR assay was able to enumerate total EHEC in 32% of the hide samples with a range of approximately 34 to 91,412 CFUs/100 cm(2) (95% CI 4-113,460 CFUs/100 cm(2)). Using the MPN assay, total EHEC was enumerable in 48% of the hide samples and ranged from approximately 1 to greater than 17,022 CFUs/100 cm(2) (95% CI 0.4-72,000 CFUs/100 cm(2)). The carcass samples had lower amounts of EHEC with a range of approximately 4-275 CFUs/100 cm(2) (95% CI 3-953 CFUs/100 cm(2)) from 17% of samples with an enumerable amount of EHEC by qPCR. For the MPN assay, the carcass samples ranged from 0.1 to 1 CFUs/100 cm(2) (95% CI 0.02-4 CFUs/100 cm(2)) from 29% of the samples. The correlation coefficient between the qPCR and MPN enumeration methods indicated a moderate relation (R (2) = 0.39) for the hide samples while the carcass samples had no relation (R (2) = 0.002), which was likely due to most samples having an amount of total EHEC below the reliable limit of quantification for qPCR. Interestingly, after enrichment, 81% of the hide samples and 94% of the carcass samples had a detectable amount of total EHEC by qPCR. From our analysis, the MPN assay provided a higher percentage of enumerable hide and carcass samples, however determining an appropriate dilution range and the limited throughput offer additional challenges.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Moeykens, S.A.; Pate, M.B.
1996-11-01
This study evaluates the effects of lubricant on spray evaporation heat transfer performance. Tests were conducted with refrigerant R-134a and triangular-pitch tube bundles made from enhanced-condensation, enhanced-boiling, low-finned, and plain-surface tubes. A 340-SUS polyol-ester (POE) oil was used for the R-134a testing because this lubricant is being integrated into industry for use with this refrigerant. Refrigerant was sprayed onto the tube bundles with low-pressure-drop, wide-angle nozzles located directly above the bundle. Collector testing was conducted with both R-134a and R-22 to determine the percentage of refrigerant contacting the tue bundle. It was found that small concentrations of the polyol-ester lubricantmore » yielded significant improvement in the heat transfer performance of R-134a. The shell-side heat transfer coefficient was more dependent on lubricant concentration than on film-feed supply rate within the range of the respective parameters evaluated in this study. As expected, pure R-22 results show higher heat transfer coefficients than those obtained with pure R-134a at the same saturation temperature of 2.0 C (35.6 F).« less
Giovenzana, Valentina; Beghi, Roberto; Parisi, Simone; Brancadoro, Lucio; Guidetti, Riccardo
2018-03-01
Increasing attention is being paid to non-destructive methods for water status real time monitoring as a potential solution to replace the tedious conventional techniques which are time consuming and not easy to perform directly in the field. The objective of this study was to test the potential effectiveness of two portable optical devices (visible/near infrared (vis/NIR) and near infrared (NIR) spectrophotometers) for the rapid and non-destructive evaluation of the water status of grapevine leaves. Moreover, a variable selection methodology was proposed to determine a set of candidate variables for the prediction of water potential (Ψ, MPa) related to leaf water status in view of a simplified optical device. The statistics of the partial least square (PLS) models showed in validation R 2 between 0.67 and 0.77 for models arising from vis/NIR spectra, and R 2 ranged from 0.77 to 0.85 for the NIR region. The overall performance of the multiple linear regression (MLR) models from selected wavelengths was slightly worse than that of the PLS models. Regarding the NIR range, acceptable MLR models were obtained only using 14 effective variables (R 2 range 0.63-0.69). To address the market demand for portable optical devices and heading towards the trend of miniaturization and low cost of the devices, individual wavelengths could be useful for the design of a simplified and low-cost handheld system providing useful information for better irrigation scheduling. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.
Argekar, A P; Powar, S G
2000-01-01
A new simple, precise, rapid and selective high-performance thin-layer chromatographic (HPTLC) method has been developed for the simultaneous determination of atenolol (ATL) and amlodipine (AMLO) in tablets, using methylene chloride:methanol:ammonia solution (25% NH3) (8.8:1.3:0.1; v/v) as the mobile phase and Merck HPTLC plates (0.2 mm thickness) precoated with 60F254 silica gel on aluminium sheet as the stationary phase. Detection was carried out densitometrically using a UV detector at 230 nm. The retention factors of ATL and AMLO were 0.33 and 0.75, respectively. Calibration curves were linear in the range 10-500 microg ml(-1) for both. Assays of ATL and AMLO were 49.87 mg per tablet (relative standard deviation (R.S.D.), 1.3%) and 4.90 mg per tablet (R.S.D., 1.38%) for brand I, and 49.27 mg per tablet (R.S.D., 1.12%) and 4.98 mg per tablet (R.S.D., 1.42%) for brand II, respectively. The percentage recoveries for ATL and AMLO for brands I and II were 99.06 and 99.30%, and 99.27 and 99.15%, respectively.
HS-SPME determination of volatile carbonyl and carboxylic compounds in different matrices.
Stashenko, Elena E; Mora, Amanda L; Cervantes, Martha E; Martínez, Jairo R
2006-07-01
Specific chromatographic methodologies are developed for the analysis of carboxylic acids (C(2)-C(6), benzoic) and aldehydes (C(2)-C(10)) of low molecular weight in diverse matrices, such as air, automotive exhaust gases, human breath, and aqueous matrices. For carboxylic acids, the method is based on their reaction with pentafluorobenzyl bromide in aqueous solution, followed by the separation and identification of the resultant pentafluorobenzyl esters by means of headspace (HS)-solid-phase microextraction (SPME) combined with gas chromatography (GC) and electron capture detection (ECD). Detection limits in the microg/m(3) range are reached, with relative standard deviation (RSD) less than 10% and linear response (R(2) > 0.99) over two orders of magnitude. The analytical methodology for aldehydes is based on SPME with simultaneous derivatization of the analytes on the fiber, by reaction with pentafluorophenylhydrazine. The derivatization reagent is previously deposited on the SPME fiber, which is then exposed to the gaseous matrix or the HS of the sample solution. The pentafluorophenyl hydrazones formed on the fiber are analyzed selectively by means of GC-ECD, with detection limits in the ng/m(3) range, RSD less than 10%, and linear response (R(2) > 0.99) over two orders of magnitude.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Grigorov, Grigor N.; Chow, James C.L.; Grigorov, Lenko
2006-05-15
The normal tissue complication probability (NTCP) is a predictor of radiobiological effect for organs at risk (OAR). The calculation of the NTCP is based on the dose-volume-histogram (DVH) which is generated by the treatment planning system after calculation of the 3D dose distribution. Including the NTCP in the objective function for intensity modulated radiation therapy (IMRT) plan optimization would make the planning more effective in reducing the postradiation effects. However, doing so would lengthen the total planning time. The purpose of this work is to establish a method for NTCP determination, independent of a DVH calculation, as a quality assurancemore » check and also as a mean of improving the treatment planning efficiency. In the study, the CTs of ten randomly selected prostate patients were used. IMRT optimization was performed with a PINNACLE3 V 6.2b planning system, using planning target volume (PTV) with margins in the range of 2 to 10 mm. The DVH control points of the PTV and OAR were adapted from the prescriptions of Radiation Therapy Oncology Group protocol P-0126 for an escalated prescribed dose of 82 Gy. This paper presents a new model for the determination of the rectal NTCP ({sub R}NTCP). The method uses a special function, named GVN (from Gy, Volume, NTCP), which describes the {sub R}NTCP if 1 cm{sup 3} of the volume of intersection of the PTV and rectum (R{sub int}) is irradiated uniformly by a dose of 1 Gy. The function was 'geometrically' normalized using a prostate-prostate ratio (PPR) of the patients' prostates. A correction of the {sub R}NTCP for different prescribed doses, ranging from 70 to 82 Gy, was employed in our model. The argument of the normalized function is the R{sub int}, and parameters are the prescribed dose, prostate volume, PTV margin, and PPR. The {sub R}NTCPs of another group of patients were calculated by the new method and the resulting difference was <{+-}5% in comparison to the NTCP calculated by the PINNACLE3 software where Kutcher's dose-response model for NTCP calculation is adopted.« less
Algorithms to qualify respiratory data collected during the transport of trauma patients.
Chen, Liangyou; McKenna, Thomas; Reisner, Andrew; Reifman, Jaques
2006-09-01
We developed a quality indexing system to numerically qualify respiratory data collected by vital-sign monitors in order to support reliable post-hoc mining of respiratory data. Each monitor-provided (reference) respiratory rate (RR(R)) is evaluated, second-by-second, to quantify the reliability of the rate with a quality index (QI(R)). The quality index is calculated from: (1) a breath identification algorithm that identifies breaths of 'typical' sizes and recalculates the respiratory rate (RR(C)); (2) an evaluation of the respiratory waveform quality (QI(W)) by assessing waveform ambiguities as they impact the calculation of respiratory rates and (3) decision rules that assign a QI(R) based on RR(R), RR(C) and QI(W). RR(C), QI(W) and QI(R) were compared to rates and quality indices independently determined by human experts, with the human measures used as the 'gold standard', for 163 randomly chosen 15 s respiratory waveform samples from our database. The RR(C) more closely matches the rates determined by human evaluation of the waveforms than does the RR(R) (difference of 3.2 +/- 4.6 breaths min(-1) versus 14.3 +/- 19.3 breaths min(-1), mean +/- STD, p < 0.05). Higher QI(W) is found to be associated with smaller differences between calculated and human-evaluated rates (average differences of 1.7 and 8.1 breaths min(-1) for the best and worst QI(W), respectively). Establishment of QI(W) and QI(R), which ranges from 0 for the worst-quality data to 3 for the best, provides a succinct quantitative measure that allows for automatic and systematic selection of respiratory waveforms and rates based on their data quality.
Himmelberg, Glen R.; Brew, David A.
2005-01-01
The western metamorphic belt is part of the Coast Mountains Complex of southeastern Alaska and western Canada. This complex formed as a result of mid-Cretaceous through middle Eocene crustal shortening between the previously amalgamated Wrangellia and Alexander terranes (Insular superterrane) and previously accreted terranes of the North American continental margin (Intermontane superterrane). The western metamorphic belt, which ranges from a few kilometers to several tens of kilometers in width, records a complex sequence of contact-metamorphic and regional metamorphic events, the most significant of which are designated M1R, M2C-R, and M3R. The M1R regional metamorphic event ranged in grade from subgreenschist to greenschist facies and was overprinted by the M2C-R and M3R metamorphic events. The M2C-R metamorphic event is recorded in discrete contact-metamorphic aureoles and regional metamorphic-mineral assemblages related to tonalite-granodiorite plutons of the Admiralty-Revillagigedo plutonic belt. The M3R metamorphic belt, which is adjacent to the M2C-R belt, is characterized by regional Barrovian isograds of garnet, staurolite, kyanite, and sillimanite. Using the THERMOCALC program, pressure-temperature (P-T) conditions for the M2C-R metamorphic event are estimated to be in the ranges 5.3-7.5 kbars and 525-640 deg.C and for the M3R metamorphic event in the ranges 9.4-12.6 kbars and 730-895 deg.C. The M2C-R metamorphic event occurred at approximately 90 Ma, but the timing of the M3R metamorphic event is poorly documented and uncertain. On the basis of an 40Ar/39Ar age on actinolitic amphibole and a Sm-Nd age on garnet core, the timing of metamorphism might be constrained between 90+/-1 and 80+/-9 Ma, although the Sm-Nd age of 80+/-9 m.y. possibly reflects postpeak growth. Thermobarometric data suggest that the two events occurred at different crustal levels and followed different P-T paths. No evidence exists that M2C-R metamorphic-mineral assemblages were overprinted by the M3R metamorphic event, as proposed by some workers. Juxtaposition of the two belts of rocks probably occurred along the Coast shear zone during uplift and exhumation of the Coast Mountains.
Yamazaki, Shinji
2018-05-03
A general objective of drug-drug interaction (DDI) studies is to determine whether potential interactions of new molecular entities with concomitantly administered other drugs exist and, if DDIs occur, whether dosage adjustments are required. A typical end point for DDI evaluations is the ratio of area under the plasma concentration-time curve (AUC) of substrate drugs (AUCR), whereas the ratios of maximal plasma concentration (C max ) and terminal half-life (t 1/2 ) are also important to understand DDI mechanisms (C max R and t 1/2 R, respectively). Because changes in substrate AUC by precipitant drugs ultimately result from alterations of C max and t 1/2 , AUCR can be considered a hybrid parameter of C max R and t 1/2 R, for example, AUCR ≈ C max R × t 1/2 R. The primary objective of this study was to investigate the relationships between AUCR, C max R, and t 1/2 R in physiologically based pharmacokinetic model-predicted and clinically observed DDI results. First, the model-predicted results showed the excellent proportional relationship between AUCR and (C max R × t 1/2 R) in DDI results of virtual substrates having a wide range of oral bioavailability with coadministration of ketoconazole, ritonavir, and rifampin. Second, the reasonable proportional relationships were also observed in the clinically observed DDI results of midazolam and statins (atorvastatin, cerivastatin, fluvastatin, lovastatin, pitavastatin, pravastatin, rosuvastatin, and simvastatin) with various inhibitors and inducers. Finally, these results suggest that utilization of the proportional relationship between AUCR and (C max R × t 1/2 R) can provide an additional framework to further interpret DDI results reasonably and clearly. Furthermore, the proportional relationship can be purposely used to assess study design and pharmacokinetic analyses in DDI studies. © 2018, The American College of Clinical Pharmacology.
An Empirical Isochrone of Very Massive Stars in R136a
NASA Astrophysics Data System (ADS)
de Koter, Alex; Heap, Sara R.; Hubeny, Ivan
1998-12-01
We report on a detailed spectroscopic study of 12 very massive and luminous stars (M >~ 35M⊙) in the core of the compact cluster R136a, near the center of the 30 Doradus complex. The three brightest stars of the cluster, R136a1, R136a2, and R136a3, have been investigated earlier by de Koter, Heap, & Hubeny. Low-resolution spectra (<200 km s-1) of the program stars were obtained with the GHRS and FOS spectrographs on the Hubble Space Telescope. These instruments covered the spectral range from 1200 to 1750 Å and from 3200 to 6700 Å, respectively. Fundamental stellar parameters were obtained by fitting the observations by model spectra calculated with the unified ISA-WIND code of de Koter et al. supplemented by synthetic data calculated using the program TLUSTY. We find that the stars are almost exclusively of spectral type O3. They occupy only a relatively narrow range in effective temperatures between 40 and 46 kK. The reason for these similar Teff's is that the isochrone of these very massive stars, which we determined to be at ~2 Myr, runs almost vertically in the H-R diagram. We present a quantitative method of determining the effective temperature of O3-type stars based on the strength of the O V λ1371 line. Present-day evolutionary calculations by Meynet et al. imply that the program stars have initial masses in the range of Mi ~ 37-76 M⊙. The observed mass-loss rates are up to 3 (2) times higher than is assumed in these evolution tracks when adopting a metallicity Z = 0.004 (0.008) for the LMC. The high observed mass-loss rates imply that already at an age of ~2 Myr the most luminous of our program stars will have lost a significant fraction of their respective initial masses. For the least luminous stars investigated in this paper, the observed mass loss agrees with the prediction by the theory of radiation-driven winds (Kudritzki et al.). However, for increasing luminosity the observed mass loss becomes larger, reaching up to 3-4 times what is expected from the theory. Such an increasing discrepancy fits in with the results of de Koter et al., where an observed overpredicted mass-loss ratio of up to 8 was reported for the brightest members of the R136a cluster, for which Mi ~ 100 M⊙ was found. The failure of the theory is also present when one compares observed over predicted wind momentum as a function of wind performance number. This strongly indicates that the shortcoming of the present state of the theory is connected to the neglect of effects of multiple photon momentum transfer. Based on observations with the NASA/ESA Hubble Space Telescope obtained at the Space Telescope Science Institute, which is operated by AURA, Inc., under NASA contract NAS 5-26555.
Tóth, Gergely; Bodai, Zsolt; Héberger, Károly
2013-10-01
Coefficient of determination (R (2)) and its leave-one-out cross-validated analogue (denoted by Q (2) or R cv (2) ) are the most frequantly published values to characterize the predictive performance of models. In this article we use R (2) and Q (2) in a reversed aspect to determine uncommon points, i.e. influential points in any data sets. The term (1 - Q (2))/(1 - R (2)) corresponds to the ratio of predictive residual sum of squares and the residual sum of squares. The ratio correlates to the number of influential points in experimental and random data sets. We propose an (approximate) F test on (1 - Q (2))/(1 - R (2)) term to quickly pre-estimate the presence of influential points in training sets of models. The test is founded upon the routinely calculated Q (2) and R (2) values and warns the model builders to verify the training set, to perform influence analysis or even to change to robust modeling.
Petroleum hydrocarbons in the surface water of two estuaries in the Southeastern united states
NASA Astrophysics Data System (ADS)
Bidleman, T. F.; Castleberry, A. A.; Foreman, W. T.; Zaranski, M. T.; Wall, D. W.
1990-01-01
Surface water samples from Charleston Harbor, SC and Winyah Bay, SC were analysed for total hydrocarbons by gas chromatography (GC) and for petroleum residues (expressed as crude oil equivalents) by fluorescence spectrometry. Cleanup by column chromatography and saponification was necessary to reduce the background from extraneous fluorescing materials. Oil concentrations determined by FS ranged from 0·5-25 μg l -1 in Charleston Harbor and <0·23-9·6 μg l -1 in Winyah Bay. Hydrocarbons determined by GC were significantly correlated ( P < 0·01) with crude oil equivalents determined by FS, but the data showed considerable scatter as indicated by r2 = 0·45. Polycyclic aromatic hydrocarbons were determined by gas chromatography—mass spectrometry for one set of Winyah Bay samples. The sum of nonalkylated polycyclic aromatic hydrocarbons having ≥ 3 rings ranged from 7-64 ng l -1 at different stations. Perylene, possibly originating from sediment dredging, was one of the more abundant polycyclic aromatic hydrocarbons.
Mörschbächer, Ana Paula; Dullius, Anja; Dullius, Carlos Henrique; Bandt, Cassiano Ricardo; Kuhn, Daniel; Brietzke, Débora Tairini; Malmann Kuffel, Fernando José; Etgeton, Henrique Pretto; Altmayer, Taciélen; Gonçalves, Tamara Engelmann; Oreste, Eliézer Quadro; Ribeiro, Anderson Schwingel; de Souza, Claucia Fernanda Volken; Hoehne, Lucélia
2018-07-30
The present paper describes the validation of a spectrophotometry method involving molecular absorption in the visible ultraviolet-visible (UV-Vis) region for selenium (Se) determination in the bacterial biomass produced by lactic acid bacteria (LAB). The method was found to be suitable for the target application and presented a linearity range from 0.025 to 0.250 mg/L Se. The angular and linear coefficients of the linear equation were 1.0678 and 0.0197 mg/L Se, respectively, and the linear correlation coefficient (R 2 ) was 0.9991. Analyte recovery exceeded 96% with a relative standard deviation (RSD) below 3%. The Se contents in LAB ranged from 0.01 to 20 mg/g. The Se contents in the bacterial biomass determined by UV-Vis were not significantly different (p > 0.05) those determined by graphite furnace atomic absorption spectrometry. Thus, Se can be quantified in LAB biomass using this relatively simpler technique. Copyright © 2018 Elsevier Ltd. All rights reserved.
Jeong, Birang; Roh, Jong Seong; Yoon, Michung; Yoon, Yoosik; Shin, Soon Shik; Cho, Hyun Joo; Kwon, Yong Soo; Yang, Heejung
2018-01-01
Background: DF formula is a herbal preparation comprised three medicinal herbs, namely, Ephedra intermedia, Rheum palmatum, and Lithospermum erythrorhizon, which is being used for the treatment of obesity and liver fibrosis in Korean local clinics. Objective: Since the abovementioned three herbs exist with different proportions in DF formula and their chemical markers have different physiochemical properties; it is quite challenging to develop an analytical methodology for the determination of these chemical markers. Materials and Methods: For the analysis of the three herbs, five chemicals, (+)-pseudoephedrine (1) and (−)-ephedrine (2) for E. intermedia, aloe-emodin (3), and chrysophanol (4) for R. palmatum, and shikonin (5) for L. erythrorhizon, were selected for method validation of DF formula, and the analytical conditions were optimized and validated using high-performance liquid chromatography coupled with an ultraviolet detector (HPLC-UV). Results: The specificities for the five compounds 1–5 were determined by their UV absorption spectra (1–4: 215 nm and 5: 520 nm). Their calibration curves showed good linear regressions with high correlation coefficient values (R2 > 0.9997). The limits of detection of these five markers were in the range 0.4–2.1 ng/mL, with the exception of 5 (12.7 ng/mL). The intraday variability for all the chemical markers was less than a Relative standard deviation (RSD) of 3%, except for 5 (RSD = 12.6%). In the case of interday analysis, 1 (1.0%), 2 (3.1%), and 4 (3.7%) showed much lower variabilities (RSD < 5%) than 3 (7.6%) and 5 (8.2%). Moreover, the five chemical markers showed good recoveries with good accuracies in the range of 90%–110%. Conclusions: The developed HPLC-UV method for the determination of the five chemical markers of the components of DF formula was validated. SUMMARY DF formula, the herbal composition of Ephedra intermedia, Rheum palmatum and Lithospermum erythrorhizonFive chemical markers in DF formula were (+)-pseudoephedrine (1) and (-)-ephedrine (2) for E. intermedia, aloe-emodin (3) and chrysopanol (4) for R. palmatum, and shikonin (5) for L. erythrorhizon, with quite different physico-chemical propertiesFive chemical markers in DF formula were determined by HPLC-UV Abbreviations used: EP: (−)-ephedrine; PSEP: (+)-pseudoephedrine; HPLC: High-performance liquid chromatography; UV: Ultraviolet; LOD: Limit of detection; LOQ: Limit of quantification; RSD: Relative standard deviation. PMID:29720825
Siebert, T; Sust, M; Thaller, S; Tilp, M; Wagner, H
2007-04-01
We evaluate an improved method for individually determining neuromuscular properties in vivo. The method is based on Hill's equation used as a force law combined with Newton's equation of motion. To ensure the range of validity of Hill's equation, we first perform detailed investigations on in vitro single muscles. The force-velocity relation determined with the model coincides well with results obtained by standard methods (r=.99) above 20% of the isometric force. In addition, the model-predicted force curves during work loop contractions very well agree with measurements (mean difference: 2-3%). Subsequently, we deduce theoretically under which conditions it is possible to combine several muscles of the human body to model muscles. This leads to a model equation for human leg extension movements containing parameters for the muscle properties and for the activation. To numerically determine these invariant neuromuscular properties we devise an experimental method based on concentric and isometric leg extensions. With this method we determine individual muscle parameters from experiments such that the simulated curves agree well with experiments (r=.99). A reliability test with 12 participants revealed correlations r=.72-.91 for the neuromuscular parameters (p<.01). Predictions of similar movements under different conditions show mean errors of about 5%. In addition, we present applications in sports practise and theory.
Denari, Daniela; Ceballos, Nora R
2005-09-01
In rat Leydig cells, glucocorticoids (GC) inhibit testosterone (T) synthesis via glucocorticoid receptor (GR). However, GC access to GR is regulated by the local expression of 11beta-hydroxysteroid dehydrogenase (11beta-HSD). Two isoforms were identified in mammals: type 1, a NADP+-preferring enzyme with K(m) in the muM range for GC and type 2, NAD+-dependent, with K(m) in the nM range for GC. In amphibians, a seasonal rhythm in baseline GC levels was described. However, a shift in the amount of deactivating 11beta-HSD activity could alter GC effects. The purpose of this work is to describe seasonal changes in testicular activity of 11beta-HSD in Bufo arenarum as well as the annual and seasonal patterns of plasma corticosterone (B) and T. The activity of 11beta-HSD was assayed in homogenate and subcellular fractions in pre-reproductive (Pre-R), reproductive (R) and post-reproductive (Post-R) periods, using [3H]B. Plasma B and T were determined by RIA. Testicular 11beta-HSD is a microsomal NAD+-dependent enzyme with a K(m) in the nM order, its activity being strongly reduced by glycyrrhetinic acid. These results indicate that toad testes express an 11beta-HSD similar to mammalian type 2. Although 11beta-HSD activity is higher in the Post-R than in the R and Pre-R seasons (V(max): Pre-R: 0.26+/-0.10, R: 0.14+/-0.01, Post-R: 1.37+/-0.45, pmol/minmg protein), K(m) value remains constant throughout the year. A seasonal rhythm in baseline GC concentrations inversely correlated with plasma T was also described. T concentration is lower in the R season than in the other periods (Pre-R: 90+/-6; R: 12+/-1; Post-R: 56+/-3, nM) while total B concentration is higher in the breeding than in the other seasons (Pre-R: 62+/-10; R: 145+/-18; Post-R: 96+/-10, nM). Furthermore, free B (Pre-R: 51+/-8; R: 94+/-12; Post-R: 70+/-7, nM) was always below K(m) values. In conclusion, this work shows that the activity of 11beta-HSD in toad testes could modulate GC action by transforming active hormones in the corresponding inactive steroid.
Kuiper, Gerhardus J A J M; Houben, Rik; Wetzels, Rick J H; Verhezen, Paul W M; Oerle, Rene van; Ten Cate, Hugo; Henskens, Yvonne M C; Lancé, Marcus D
2017-11-01
Low platelet counts and hematocrit levels hinder whole blood point-of-care testing of platelet function. Thus far, no reference ranges for MEA (multiple electrode aggregometry) and PFA-100 (platelet function analyzer 100) devices exist for low ranges. Through dilution methods of volunteer whole blood, platelet function at low ranges of platelet count and hematocrit levels was assessed on MEA for four agonists and for PFA-100 in two cartridges. Using (multiple) regression analysis, 95% reference intervals were computed for these low ranges. Low platelet counts affected MEA in a positive correlation (all agonists showed r 2 ≥ 0.75) and PFA-100 in an inverse correlation (closure times were prolonged with lower platelet counts). Lowered hematocrit did not affect MEA testing, except for arachidonic acid activation (ASPI), which showed a weak positive correlation (r 2 = 0.14). Closure time on PFA-100 testing was inversely correlated with hematocrit for both cartridges. Regression analysis revealed different 95% reference intervals in comparison with originally established intervals for both MEA and PFA-100 in low platelet or hematocrit conditions. Multiple regression analysis of ASPI and both tests on the PFA-100 for combined low platelet and hematocrit conditions revealed that only PFA-100 testing should be adjusted for both thrombocytopenia and anemia. 95% reference intervals were calculated using multiple regression analysis. However, coefficients of determination of PFA-100 were poor, and some variance remained unexplained. Thus, in this pilot study using (multiple) regression analysis, we could establish reference intervals of platelet function in anemia and thrombocytopenia conditions on PFA-100 and in thrombocytopenia conditions on MEA.
Use of Thematic Mapper for water quality assessment
NASA Technical Reports Server (NTRS)
Horn, E. M.; Morrissey, L. A.
1984-01-01
The evaluation of simulated TM data obtained on an ER-2 aircraft at twenty-five predesignated sample sites for mapping water quality factors such as conductivity, pH, suspended solids, turbidity, temperature, and depth, is discussed. Using a multiple regression for the seven TM bands, an equation is developed for the suspended solids. TM bands 1, 2, 3, 4, and 6 are used with logarithm conductivity in a multiple regression. The assessment of regression equations for a high coefficient of determination (R-squared) and statistical significance is considered. Confidence intervals about the mean regression point are calculated in order to assess the robustness of the regressions used for mapping conductivity, turbidity, and suspended solids, and by regressing random subsamples of sites and comparing the resultant range of R-squared, cross validation is conducted.
Solid-Phase and Oscillating Solution Crystallization Behavior of (+)- and (-)-N-Methylephedrine.
Tulashie, Samuel Kofi; Polenske, Daniel; Seidel-Morgenstern, Andreas; Lorenz, Heike
2016-11-01
This work involves the study of the solid-phase and solution crystallization behavior of the N-methylephedrine enantiomers. A systematic investigation of the melt phase diagram of the enantiomeric N-methylephedrine system was performed considering polymorphism. Two monotropically related modifications of the enantiomer were found. Solubilities and the ternary solubility phase diagrams of N-methylephedrine enantiomers in 2 solvents [isopropanol:water, 1:3 (Vol) and (2R, 3R)-diethyl tartrate] were determined in the temperature ranges between 15°C and 25°C, and 25°C and 40°C, respectively. Preferential nucleation and crystallization experiments at higher supersaturation leading to an unusual oscillatory crystallization behavior as well as a successful preferential crystallization experiment at lower supersaturation are presented and discussed. Copyright © 2016. Published by Elsevier Inc.
Simonds, Elise C; Handel, Richard W; Archer, Robert P
2008-03-01
This study evaluated the incremental validity of scores from the Minnesota Multiphasic Personality Inventory-2 (MMPI-2) and the Symptom Checklist-90-Revised (SCL-90-R) in a sample of mental health inpatients originally published by Archer, Griffin, and Aiduk (1995). The incremental validity of scores from the SCL-90-R primary symptom dimensions and MMPI-2 Clinical, Content, and Restructured Clinical scales was assessed in a sample of 544 mental health inpatients using conceptually related items from the Brief Psychiatric Rating Scale (BPRS) as criteria. A series of hierarchical multiple regressions indicated that scores from the SCL-90-R primary symptom dimensions exhibited limited incremental validity (Mdn DeltaR(2) = .01, range = 0-.01), whereas scores from MMPI-2 scales contributed additional information in the prediction of ratings on all but one BPRS item (Mdn DeltaR( 2) = .08, range = .04-.12).
[Correlation between degree of conversion, microhardness and inorganic content in composites].
Neves, Alisson Discacciati; Discacciati, José Augusto César; Orêfice, Rodrigo Lambert; Jansen, Wellington Corrêa
2002-01-01
The purpose of this study was to evaluate the correlation between degree of conversion and microhardness in dental composites, as well as the effect of the inorganic content and type of photo-curing unit on these parameters. Three indirect composites (Artglass, Solidex and Zeta LC) were polymerized by means of three different laboratorial units (UniXS, Solidilite and an experimental device). For each material, fifteen samples were prepared using a metal matrix. The degree of conversion was analyzed by means of infrared spectroscopy, and microhardness was also assessed. The inorganic content was measured by means of thermogravimetric analysis (TGA). The Pearson s test was carried out in order to determine correlations. The degree of conversion of Artglass ranged from 37.5% to 79.2%, and its microhardness, from 32.4 to 50.3 (r = 0.904). The degree of conversion of Solidex ranged from 41.2% to 60.4%, and its microhardness, from 33.3 to 44.1 (r = 0.707). The degree of conversion and the microhardness of Zeta LC ranged from 62.0% to 78.0% and from 22.6 to 33.6, respectively (r = 0.710). It was concluded that the utilization of different photo-curing units caused variations on the degree of conversion, as a result of specific characteristics of each unit. For each material, there was strong correlation between the degree of conversion and microhardness. In addition, when different materials were compared, microhardness was more affected by filler content than by the degree of conversion.
Microemulsion Formulation of Carbendazim and Its In Vitro Antifungal Activities Evaluation
Leng, Pengfei; Zhang, Zhiming; Li, Qian; Zhao, Maojun; Pan, Guangtang
2014-01-01
The fungus Rhizoctonia solani Kuhn is a widespread and destructive plant pathogen with a very broad host range. Although various pathogens, including R. solani, have been traditionally controlled using chemical pesticides, their use faces drawbacks such as environmental pollution, development of pesticide resistance, and other negative effects. Carbendazim is a well-known antifungal agent capable of controlling a broad range of plant diseases, but its use is hampered by its poor aqueous solubility. In this study, we describe an environmentally friendly pharmaceutical microemulsion system using carbendazim as the active ingredient, chloroform and acetic acid as solvents, and the surfactants HSH and 0204 as emulsifiers. This system increased the solubility of carbendazim to 30 g/L. The optimal microemulsion formulation was determined based on a pseudo-ternary phase diagram; its physicochemical characteristics were also tested. The cloud point was greater than 90°C and it was resistant to freezing down to −18°C, both of which are improvements over the temperature range in which pure carbendazim can be used. This microemulsion meets the standard for pesticide microemulsions and demonstrated better activity against R. solani AG1-IA, relative to an aqueous solution of pure carbendazim (0.2 g/L). The mechanism of activity was reflected in the inhibition of against R. solani AG1-IA including mycelium growth, and sclerotia formation and germination were significantly better than that of 0.2 g/L carbendazim water solution according to the results of t-test done by SPSS 19. PMID:25310219
Microemulsion formulation of Carbendazim and its in vitro antifungal activities evaluation.
Leng, Pengfei; Zhang, Zhiming; Li, Qian; Zhao, Maojun; Pan, Guangtang
2014-01-01
The fungus Rhizoctonia solani Kuhn is a widespread and destructive plant pathogen with a very broad host range. Although various pathogens, including R. solani, have been traditionally controlled using chemical pesticides, their use faces drawbacks such as environmental pollution, development of pesticide resistance, and other negative effects. Carbendazim is a well-known antifungal agent capable of controlling a broad range of plant diseases, but its use is hampered by its poor aqueous solubility. In this study, we describe an environmentally friendly pharmaceutical microemulsion system using carbendazim as the active ingredient, chloroform and acetic acid as solvents, and the surfactants HSH and 0204 as emulsifiers. This system increased the solubility of carbendazim to 30 g/L. The optimal microemulsion formulation was determined based on a pseudo-ternary phase diagram; its physicochemical characteristics were also tested. The cloud point was greater than 90°C and it was resistant to freezing down to -18°C, both of which are improvements over the temperature range in which pure carbendazim can be used. This microemulsion meets the standard for pesticide microemulsions and demonstrated better activity against R. solani AG1-IA, relative to an aqueous solution of pure carbendazim (0.2 g/L). The mechanism of activity was reflected in the inhibition of against R. solani AG1-IA including mycelium growth, and sclerotia formation and germination were significantly better than that of 0.2 g/L carbendazim water solution according to the results of t-test done by SPSS 19.
Ke, Changliang; Liu, Qi; Li, Liudong; Chen, Jiewen; Wang, Xunuo; Huang, Ke
2016-09-15
Gas chromatography (GC) coupled with triple quadrupole tandem mass spectrometry (MS/MS) operated in electron ionization mode (EI) has been shown to have advantages in the trace analysis of chemical compounds. Employing the instrument, a method has been built to simultaneously determine eugenol, isoeugenol' and methyleugenol, which have been widely used as fish anesthetic, in the fish fillet. Procedure for the sample preparation was achieved by using hexane extraction followed by phenyl solid phase extraction (SPE) cleanup, which was free of such steps as rotary evaporation and nitrogen blowing by taking the volatility of eugenol and its isomers into consideration. The method was validated by conducting recovery studies on fortified fish fillet samples at four concentrations. The linearity in the range of 5-500μg·L(-1) was forced through the origin giving a coefficient of determination (r(2)) greater than 0.9982. Limits of detection (LODs) for eugenol, isoeugenol' and methyleugenol were 0.4, 1.2' and 0.2μg·kg(-1), respectively. The limits of quantification (LOQs) were 1.2, 4' and 0.7μg·kg(-1) for eugenol, isoeugenol' and methyleugenol, respectively. The recoveries for eugenol and its isomers ranged from 76.4 to 99.9% with relative standard deviations (RSD) in a range from 2.18 to 15.5%. This method is quick, simple and suitable for determining the residues of eugenol, isoeugenol and methyleugenol simultaneously in batch samples of fish fillet. Copyright © 2016 Elsevier B.V. All rights reserved.
Peng, Xiaojun; Pang, Jinshan; Deng, Aihua
2011-12-01
A novel method for the simultaneous determination of seven phenoxyacid herbicides such as dicamba, fluroxypyr, 4-chlorophenoxyacetic acid (4-CPA), 2-methyl-4-chlorophenoxyacetic acid (MCPA), 2, 4-dichlorophenoxyacetic acid (2,4-D), 2,4-dichlorophenoxybutyric acid (2,4-DB) and 4-(2-methyl-4-chlorophenoxy) butyric acid (MCPB) in environmental water by three phase hollow fiber liquid phase microextraction (HF-LPME) coupled with high performance liquid chromatography (HPLC) was developed. In order to optimize the experimental conditions, the orthogonal test has been used. The effects of extraction solvent, pH of the donor phase and acceptor phase, extraction time, stirring speed and salt concentration on the detection were investigated. The optimal experimental conditions were as follows: octanol as organic solvent, pH 3 of donor phase, pH 12 of acceptor phase, extraction time of 30 min, stirring speed of 400 r/min. The results showed that the proposed method provided a wide linear range for 7 phenoxyacid herbicides with correlation coefficients of 0.995 3 - 0.998 8. The detection limits ranged from 0.2 to 1.0 microg/L. The enrichment factors were in the range of 76.7 - 121. The recoveries were in the range of 68% - 104% and the relative standard deviations (RSDs) were less than 8.1% for the environmental water samples. The method has the advantages of sensitivity, simplicity, fastness and the use of very small amounts of organic solvent. The method can meet the requirements of the determination of trace phenoxyacid herbicides in the environmental water samples, and the study provided a useful method for the analysis of trace substances in water samples.
Fernández-Elías, Valentín E; Martínez-Abellán, Alberto; López-Gullón, José María; Morán-Navarro, Ricardo; Pallarés, Jesús G; De la Cruz-Sánchez, Ernesto; Mora-Rodriguez, Ricardo
2014-01-01
In Olympic combat sports, weight cutting is a common practice aimed to take advantage of competing in weight divisions below the athlete's normal weight. Fluid and food restriction in combination with dehydration (sauna and/or exercise induced profuse sweating) are common weight cut methods. However, the resultant hypohydration could adversely affect health and performance outcomes. The aim of this study is to determine which of the routinely used non-invasive measures of dehydration best track urine osmolality, the gold standard non-invasive test. Immediately prior to the official weigh-in of three National Championships, the hydration status of 345 athletes of Olympic combat sports (i.e., taekwondo, boxing and wrestling) was determined using five separate techniques: i) urine osmolality (UOSM), ii) urine specific gravity (USG), iii) urine color (UCOL), iv) bioelectrical impedance analysis (BIA), and v) thirst perception scale (TPS). All techniques were correlated with UOSM divided into three groups: euhydrated (G1; UOSM 250-700 mOsm · kg H2O(-1)), dehydrated (G2; UOSM 701-1080 mOsm · kg H2O(-1)), and severely dehydrated (G3; UOSM 1081-1500 mOsm · kg H2O(-1)). We found a positive high correlation between the UOSM and USG (r = 0.89: p = 0.000), although this relationship lost strength as dehydration increased (G1 r = 0.92; G2 r = 0.73; and G3 r = 0.65; p = 0.000). UCOL showed a moderate although significant correlation when considering the whole sample (r = 0.743: p = 0.000) and G1 (r = 0.702: p = 0.000) but low correlation for the two dehydrated groups (r = 0.498-0.398). TPS and BIA showed very low correlation sizes for all groups assessed. In a wide range of pre-competitive hydration status (UOSM 250-1500 mOsm · kg H2O(-1)), USG is highly associated with UOSM while being a more affordable and easy to use technique. UCOL is a suitable tool when USG is not available. However, BIA or TPS are not sensitive enough to detect hypohydration at official weight-in before an Olympic combat championship.
Yadav, Narayan Prasad; Meher, Jaya Gopal; Pandey, Neelam; Luqman, Suaib; Yadav, Kuldeep Singh; Chanda, Debabrata
2013-01-01
The present work was aimed to develop an antiseptic cream formulation of Indian basil oil utilizing hydrophilic-lipophilic balance approach. In order to determine the required-hydrophilic lipophilic balance (rHLB) of basil oil, emulsions of basil oil were prepared by phase inversion temperature technique using water, Tween 80, and Span 80. Formulated emulsions were assessed for creaming (BE9; 9.8, BE10; 10.2), droplet size (BE18; 3.22 ± 0.09 μm), and turbidity (BE18; 86.12 ± 2.1%). To ensure correctness of the applied methodology, rHLB of light liquid paraffin was also determined. After rHLB determination, basil oil creams were prepared with two different combinations of surfactants, namely, GMS : Tween 80 (1 : 3.45) and SLS : GMS (1 : 3.68), and evaluated for in vitro antimicrobial activity, skin irritation test, viscosity and consistency. The rHLB of basil oil and light liquid paraffin were found to be 13.36 ± 0.36 and 11.5 ± 0.35, respectively. Viscosity, and consistency parameters of cream was found to be consistent over 90 days. Cream formulations showed net zone of growth inhibition in the range of 5.0–11.3 mm against bacteria and 4.3–7.6 mm against fungi. Primary irritation index was found to be between 0.38 and1.05. Conclusively stable, consistent, non-irritant, enriched antiseptic basil oil cream formulations were developed utilizing HLB approach. PMID:23984361
Neufeld, Stanley; Rosin, Jessica M; Ambasta, Anshula; Hui, Kristen; Shaneman, Venessa; Crowder, Ray; Vickerman, Lori; Cobb, John
2012-10-01
R-spondins are secreted ligands that bind cell surface receptors and activate Wnt/β-catenin signaling. Human mutations and gene inactivation studies in mice have revealed a role for these four proteins (RSPO1-4) in diverse developmental processes ranging from sex determination to limb development. Among the genes coding for R-spondins, only inactivation of Rspo3 shows early embryonic lethality (E10.5 in mice). Therefore, a conditional allele of this gene is necessary to understand the function of R-spondins throughout murine development. To address this need, we have produced an allele in which loxP sites flank exons 2-4 of Rspo3, allowing tissue-specific deletion of these exons in the presence of Cre recombinase. We used these mice to investigate the role of Rspo3 during limb development and found that limbs ultimately developed normally in the absence of Rspo3 function. However, severe hindlimb truncations resulted when Rspo3 and Rspo2 mutations were combined, demonstrating redundant function of these genes. Copyright © 2012 Wiley Periodicals, Inc.
Form and stability of aluminum hydroxide complexes in dilute solution
Hem, John David; Roberson, Charles Elmer
1967-01-01
Laboratory studies of solutions 4.53 x 10 -4 to 4.5 x 10 -5 molal (12.2-1.2 ppm) in aluminum, in 0.01 molal sodium perchlorate, were conducted to obtain information as to the probable behavior of aluminum in natural water. When the solutions were brought to pH 7.5-9.5 and allowed to stand for 24 hours, a precipitate was obtained which was virtually amorphous as shown by X-rays, and which had a solubility equivalent to that of boehmite. This precipitate had a hydrolysis constant (*Ks4) of 1.93 x 10 -13a. When solutions were allowed to stead at this pH range for 10 days, their precipitates gave the X-ray pattern of bayerite (*Ks4 = 1.11 > (10- 4). These hydrolysis constants were obtained at 25?C. and corrected to zero ionic strength and are in close agreement with other published values. The predominant dissolved form in this pH range is Al(OH) -4. Below neutral pH (7.0) the dissolved aluminum species consist of octahedral units in which each aluminum ion is surrounded by six water molecules or hydroxide ions. Single units such as Al(OH2)6 + 3 and AlOH(OH2)5+2 are most abundant below pH 5.0, and where the molar ratio (r) of combined hydroxide to total dissolved aluminum is low. When r is greater than 1.0, polymerization of the octahedral units occurs. When r is between 2.0 and 3.0, solutions aged for 10 days or more contained colloidal particles between 0.10 and 0.45 ? in diameter. Particles whose diameters were greater than 0.10 ? were identified by X-ray diffraction as gibbsite. Particles smaller than 0.10 ? were also present and were shown by means of the electron microscope to have a hexagonal crystal pattern. Structured material consisting of sheets of coalesced six-membered rings of aluminum ions held together by double OH bridges has a distinctive kinetic behavior. This property was used to determine amounts of polymerized material in solutions having r between 1.0 and 3.0 after aging times ranging from a few hours to more than 4 months. Aging increased the size and orderliness of the polymeric aggregates and was accompanied by a decrease in the pH of the solution. The kinetic experiments and stoichiometric data for solutions aged for long periods provided a means of determining activities of polymerized aluminum. From these values the solubility product for microcrystalline gibbsite was determined to be 2.24 x 10 -3, and its free energy of formation, -? 272.3 0.4 kcal per mole. Where polymerization was observed, the process did not stop with small polynuclear complexes containing a few aluminum ions, but proceeded with aging until macromolecules or colloidal-sized particles were formed.
NASA Astrophysics Data System (ADS)
Alonso, J. A.; Cascales, C.; García Casado, P.; Rasines, I.
1997-02-01
The crystal structure of the ordered perovskites Ba2(RSb)O6(R=Y, Ho) is refined from neutron powder diffraction data in the space groupFmoverline3m(No. 225),Z=4, with Ba at 8(c),Rat 4(b), Sb at 4(a), oxygen at 24(e), oxygen positional parameterx=0.2636(2) forR=Y and Ho, and unit cell dimensions ofa/Å=8.4240(3) and 8.4170(2) forR=Y and Ho, respectively. Bond-valence analysis explains how the highly covalent Sb-O bonds determine the overall structure of these perovskites in whichR-O and Ba-O bonds are under compressive and tensile stresses, respectively. The magnetic susceptibility of Ba2(HoSb)O6has been measured in the temperature range 2-350 K. From ana prioriestimation of the crystal-field parameters corresponding to the point site symmetry of the rare-earth,Oh, and using the wave functions associated with the energy levels obtained, the paramagnetic susceptibility and its evolution vs temperature is simulated according to the van Vleck formalism. The observed deviation from the Curie-Weiss behavior at low temperature, very well reproduced, reflects the splitting of the ground state of this cation under the influence of the crystal field.
Interaction model between a liquid film and a spherical probe
NASA Astrophysics Data System (ADS)
Ledesma Alonso, Rene; Legendre, Dominique; Tordjeman, Philippe
2012-11-01
To find a liquid surface profile, when performing AFM measurements, probe interaction effects should be identified. Herein, the behavior of a liquid film free surface (thickness E, surface tension γ and density difference Δρ), disposed over a flat surface and in the presence of a spherical probe (radius R) is forecast. A bump-like surface shape is observed, due to the probe/film interaction (characterized by the Hamaker constant Hpl). In addition, the attraction between the film and the substrate (depicted by Hsl) opposes the axial and radial deformation ranges. Several parameters portray the equilibrium shape: Bond Bo = (ΔρgR2) / γ and modified Hamaker Ha = 4Hpl / (3 πγR2) numbers, Hamaker ratio A =Hls /Hpl , separation distance D / R and film thickness E / R . We focus on the effect of geometry, nevertheless special attention is given to the role of physical parameters. Employing an augmented Young-Laplace equation, the equilibrium profile is described by a strongly non-linear ODE. A critical distance, below which the irreversible wetting process of the spherical probe occurs, is predicted. Our results provide simple relationships between parameters, which determine the optimal scanning conditions over liquid films.
Microbiological assay for the determination of meropenem in pharmaceutical dosage form.
Mendez, Andreas S L; Weisheimer, Vanessa; Oppe, Tércio P; Steppe, Martin; Schapoval, Elfrides E S
2005-04-01
Meropenem is a highly active carbapenem antibiotic used in the treatment of a wide range of serious infections. The present work reports a microbiological assay, applying the cylinder-plate method, for the determination of meropenem in powder for injection. The validation method yielded good results and included linearity, precision, accuracy and specificity. The assay is based on the inhibitory effect of meropenem upon the strain of Micrococcus luteus ATCC 9341 used as the test microorganism. The results of assay were treated statistically by analysis of variance (ANOVA) and were found to be linear (r=0.9999) in the range of 1.5-6.0 microg ml(-1), precise (intra-assay: R.S.D.=0.29; inter-assay: R.S.D.=0.94) and accurate. A preliminary stability study of meropenem was performed to show that the microbiological assay is specific for the determination of meropenem in the presence of its degradation products. The degraded samples were also analysed by the HPLC method. The proposed method allows the quantitation of meropenem in pharmaceutical dosage form and can be used for the drug analysis in routine quality control.
Yang, J; Chen, L
1998-03-01
This paper reports the quantitative determination of 10-HDA in Chinese traditional medicine preparations by HPLC. Spherisorb C18 column was used. The mobile phase consisted of methanol-distilled water and phosphoric acid(45:55:0.5, V/V). The elute was monitored at 210 nm. The good linearity was shown between the concentration of 10-HDA and peak area in the concentration range of 6.0-30.0 mg/L (r = 0.9999, n = 5). The detection limit was 0.2 mg/L (S:N = 3:1). The within-day and between-day RSD were 2.1%-2.2% and 2.9%-4.0%, respectively. Peaks of 10-HDA and impurities in these samples were separated completely. This method is simple, sensitive and accurate.
Changes in heart rate and heart rate variability during transportation of horses by road and air.
Ohmura, Hajime; Hobo, Seiji; Hiraga, Atsushi; Jones, James H
2012-04-01
To determine the influence of transportation by road and air on heart rate (HR) and HR variability (HRV) in horses. Animals-6 healthy horses. ECG recordings were obtained from horses before (quarantine with stall rest [Q]; 24 hours) and during a journey that included transportation by road (RT; 4.5 hours), waiting on the ground in an air stall (W; 5.5 hours), and transportation by air (AT; 11 hours); HR was determined, and HRV indices of autonomic nervous activity (low-frequency [LF; 0.01 to 0.07 Hz] and high-frequency [HF; 0.07 to 0.6 Hz] power) were calculated. Mean ± SD HRs during Q, RT, W, and AT were 38.9 ± 1.5 beats/min, 41.7 ± 5.6 beats/min, 41.5 ± 4.3 beats/min, and 48.8 ± 5.6 beats/min, respectively; HR during AT was significantly higher than HR during Q. The LF power was significantly higher during Q (3,454 ± 1,087 milliseconds(2)) and AT (3,101 ± 567 milliseconds(2)) than it was during RT (1,824 ± 432 milliseconds(2)) and W (2,072 ± 616 milliseconds(2)). During Q, RT, W, and AT, neither HF powers (range, 509 to 927 milliseconds(2)) nor LF:HF ratios (range, 4.1 to 6.2) differed significantly. The HR during RT was highly correlated with LF power (R(2) = 0.979), and HR during AT was moderately correlated with the LF:HF ratio (R(2) = 0.477). In horses, HR and HRV indices during RT and AT differed, suggesting that exposure to different stressors results in different autonomic nervous influences on HR.
Minimally nonlocal nucleon-nucleon potentials with chiral two-pion exchange including Δ resonances
DOE Office of Scientific and Technical Information (OSTI.GOV)
Piarulli, M.; Girlanda, L.; Schiavilla, R.
In this study, we construct a coordinate-space chiral potential, including Δ-isobar intermediate states in its two-pion-exchange component up to order Q 3 (Q denotes generically the low momentum scale). The contact interactions entering at next-to-leading and next-to-next-to-next-to-leading orders (Q 2 and Q 4, respectively) are rearranged by Fierz transformations to yield terms at most quadratic in the relative momentum operator of the two nucleons. The low-energy constant multiplying these contact interactions are fitted to the 2013 Granada database, consisting of 2309 pp and 2982 np data (including, respectively, 148 and 218 normalizations) in the laboratory-energy range 0–300 MeV. For themore » total 5291 $pp$ and $np$ data in this range, we obtain a Χ 2 /datum of roughly 1.3 for a set of three models characterized by long- and short-range cutoffs, R L and R S respectively, ranging from (R L,R S)=(1.2,0.8) fm down to (0.8,0.6) fm. The long-range (short-range) cutoff regularizes the one- and two-pion exchange (contact) part of the potential.« less
Minimally nonlocal nucleon-nucleon potentials with chiral two-pion exchange including Δ resonances
Piarulli, M.; Girlanda, L.; Schiavilla, R.; ...
2015-02-26
In this study, we construct a coordinate-space chiral potential, including Δ-isobar intermediate states in its two-pion-exchange component up to order Q 3 (Q denotes generically the low momentum scale). The contact interactions entering at next-to-leading and next-to-next-to-next-to-leading orders (Q 2 and Q 4, respectively) are rearranged by Fierz transformations to yield terms at most quadratic in the relative momentum operator of the two nucleons. The low-energy constant multiplying these contact interactions are fitted to the 2013 Granada database, consisting of 2309 pp and 2982 np data (including, respectively, 148 and 218 normalizations) in the laboratory-energy range 0–300 MeV. For themore » total 5291 $pp$ and $np$ data in this range, we obtain a Χ 2 /datum of roughly 1.3 for a set of three models characterized by long- and short-range cutoffs, R L and R S respectively, ranging from (R L,R S)=(1.2,0.8) fm down to (0.8,0.6) fm. The long-range (short-range) cutoff regularizes the one- and two-pion exchange (contact) part of the potential.« less
NASA Astrophysics Data System (ADS)
Gong, Aiqin; Zhu, Xiashi; Huang, Xiaoyan; Zhang, Yaqin
2008-01-01
In this work, a new flow injection analysis (FIA) for the determination of Pb 2+ in Chinese medicinal herbs was developed. In the buffer solution of borax-NaOH (pH 10.5), Pb 2+ reacted with 2-[(5-bromo-2-pyridyl)-azo]-5-(diethyl-amino)phenol (5-Br-PADAP) to form a complex. The experimental results showed that the sensitivity was enhanced in the presence of polyethyleneglycol-800 (PG-800). The main factors affecting the determination were investigated in detail. Under the optimum conditions, the linear range and detection limit is 0.0-0.3 μg/mL and 1.5 ng/mL (correlation coefficient r = 0.9996), respectively. The linear regression equation is A = -0.005 + 0.60 c (μg/mL). The sample throughout is 10 h -1. Foreign substrates effects were also investigated. The proposed method has been successfully applied to the determination of lead in reference material, goldthread and lepidium seed.
Hiranita, Takato; Soto, Paul L.; Kohut, Stephen J.; Kopajtic, Theresa; Cao, Jianjing; Newman, Amy H.; Tanda, Gianluigi
2011-01-01
Sigma receptor (σR) antagonists attenuate many behavioral effects of cocaine but typically not its reinforcing effects in self-administration procedures. However, the σR antagonist rimcazole and its N-propylphenyl analogs, [3-(cis-3,5-dimethyl-4-[3-phenylpropyl]-1-piperazinyl)-propyl]diphenylamine hydrochloride (SH 3-24) and 9-[3-(cis-3,5-dimethyl-4-[3-phenylpropyl]-1-piperazinyl)-propyl]carbazole hydrobromide (SH 3-28), dose-dependently decreased the maximal rates of cocaine self-administration without affecting comparable responding maintained by food reinforcement. In contrast, a variety of σR antagonists [N-phenethylpiperidine oxalate (AC927), N-[2-(3,4-dichlorophenyl)ethyl]-N-methyl-2-(1-pyrrolidinyl)ethylamine dihydrobromide (BD 1008), N-[2-(3,4-dichlorophenyl)ethyl]-N-methyl-2-(dimethylamino) ethylamine dihydrobromide (BD 1047), N-[2-(3,4-dichlorophenyl) ethyl]-4-methylpiperazine dihydrochloride (BD 1063), and N,N-dipropyl-2-[4-methoxy-3-(2-phenylethoxy)phenyl]-ethylamine monohydrochloride (NE-100)] had no effect on cocaine self-administration across the range of doses that decreased rates of food-maintained responding. Rimcazole analogs differed from selective σR antagonists in their dual affinities for σRs and the dopamine transporter (DAT) assessed with radioligand binding. Selective DAT inhibitors and σR antagonists were studied alone and in combination on cocaine self-administration to determine whether actions at both σRs and the DAT were sufficient to reproduce the effects of rimcazole analogs. Typical DAT inhibitors [2β-carbomethoxy-3β-(4-fluorophenyl)tropane (WIN 35,428), methylphenidate, and nomifensine] dose-dependently shifted the cocaine dose-effect curve leftward. Combinations of DAT inhibitor and σR antagonist doses that were behaviorally inactive alone decreased cocaine self-administration without effects on food-maintained responding. In addition, whereas the DAT inhibitors were self-administered at rates similar to those of cocaine, neither rimcazole analogs nor typical σR antagonists (NE-100 and AC927) maintained responding above control levels across a wide range of doses. These findings suggest that the unique effects of rimcazole analogs are due to dual actions at the DAT and σRs and that a combined target approach may have utility in development of medical treatments for cocaine abuse. PMID:21859929
Han, Shu-ying; Qiao, Jun-qin; Zhang, Yun-yang; Yang, Li-li; Lian, Hong-zhen; Ge, Xin; Chen, Hong-yuan
2011-03-01
n-Octanol/water partition coefficients (P) for DDTs and dicofol were determined by reversed-phase high performance liquid chromatography (RP-HPLC) on a C(18) column using methanol-water mixture as mobile phase. A dual-point retention time correction (DP-RTC) was proposed to rectify chromatographic retention time (t(R)) shift resulted from stationary phase aging. Based on this correction, the relationship between logP and logk(w), the logarithm of the retention factor extrapolated to pure water, was investigated for a set of 12 benzene homologues and DDT-related compounds with reliable experimental P as model compounds. A linear regression logP=(1.10±0.04) logk(w) - (0.60±0.17) was established with correlation coefficient R(2) of 0.988, cross-validated correlation coefficient R(cv)(2) of 0.983 and standard deviation (SD) of 0.156. This model was further validated using four verification compounds, naphthalene, biphenyl, 2,2-bis(4-chlorophenyl)-1,1-dichloroethane (p,p'-DDD) and 2,2-bis(4-chlorophenyl)-1,1-dichloroethene (p,p'-DDE) with similar structure to DDT. The RP-HPLC-determined P values showed good consistency with shake-flask (SFM) or slow-stirring (SSM) results, especially for highly hydrophobic compounds with logP in the range of 4-7. Then, the P values for five DDT-related compounds, 2-(2-chlorophenyl)-2-(4-chlorophenyl)-1,1,1-trichloroethane (o,p'-DDT), 2-(2-chlorophenyl)-2-(4-chlorophenyl)-1,1-dichloroethane (o,p'-DDD), 2-(2-chlorophenyl)-2-(4-chlorophenyl)-1,1-dichloroethene (o,p'-DDE), and 2,2,2-trichloro-1,1-bis(4-chlorophenyl)ethanol (dicofol) and its main degradation product 4,4'-dichlorobenzophenone (p,p'-DBP) were evaluated by the improved RP-HPLC method for the first time. The excellent precision with SD less than 0.03 proved that the novel DP-RTC protocol can significantly increases the determination accuracy and reliability of P by RP-HPLC. Copyright © 2011 Elsevier Ltd. All rights reserved.
Career track of Society of University Surgeons Resident Research Award recipients.
Hassan, Burhan; Bernstam, Elmer; Hines, O Joe; Simeone, Diane M; Weber, Sharon M; Geller, David A; Evers, B Mark; Meric-Bernstam, Funda
2013-11-01
The Society of University Surgeons (SUS) has an ongoing competitive funding program to support research training for residents. We sought to determine the career track of award recipients. We included in the study SUS resident awardees who completed awards from 1989-2007. Characteristics of awardees and their academic productivity were extracted from curriculum vitae provided by awardees (n = 24), or from online sources (n = 7). Awardees spent an average of 2.7 y (range, 1-4 y) of dedicated research time during residency. Awardees averaged 9.8 publications (range, 1-32), with 5.4 as first author (range, 1-17), with their mentor within 3 y of award completion, with an average maximum impact factor of 5.7. A total of 25 residents (81%) pursued fellowships. At an average follow-up of 11.4 y (range, 4-22 y) from the end of the award and 7.2 y (range, 0-18 y) from end of clinical training, awardees had a Hirsch index of 14.5 (range, 2-48). At the time of the study, 26 awardees (84%) were in academic surgery. Of the 23 awardees who had completed surgical training ≥ 3 y earlier, 11 (48%) received independent research funding, seven of whom (30%) received R01 or equivalent funding. The SUS resident research awardees had a productive research experience. Although our retrospective study cannot determine causation, the SUS award mechanism delivers on its promise of supporting junior surgeon-scientists who pursue academic careers and establish independent research programs. Further studies are needed to determine how rates of subsequent independent research funding can be improved. Copyright © 2013 Elsevier Inc. All rights reserved.
Vogel, M; Stern, H; Bauer, R; Bühlmeyer, K
1992-04-01
Although left ventricular (LV) mass may be important to judge effects of left-sided cardiac obstruction or hypertension, reproducible noninvasively determined normal data in the pediatric age group are scarce. To validate cross-sectional echocardiographic LV mass determination, our data were compared with LV mass assessed by magnetic resonance imaging (MRI). MRI was considered to be a good reference method because there is usually no problem in defining endo- and epicardial borders with MRI. LV mass was assessed in 14 children aged 5.3 years (10 days to 14.7 years) with a mean body surface area of 0.78 m2 (range 0.25 to 1.61). With cross-sectional echocardiography the epicardial and endocardial volumes were calculated using a Simpsons rule algorithm in the apical 2- and 4-chamber view. The difference between epi- and endocardial volumes was multiplied by 1.05 to yield the mass. Mass was assessed with MRI using a multislice technique; the area of each myocardial slice was calculated and multiplied with the slice thickness, and the resultant slice volumes were added to obtain the myocardial volume. On cross-sectional echocardiography, the mass was 55 g (range 12 to 126) or 64 g/m2 (range 46 to 79); on MRI it was 60 g (range 33 to 87) or 69 g/m2 (range 46 to 89). Regression analysis yielded an r value of 0.98 with a standard error of the estimate of 5.7 g or a 10% difference. In older children, LV mass determined by MRI was bigger than the one derived by echocardiography. It is concluded that cross-sectional echocardiography can reliably assess LV myocardial mass in pediatric patients.
Maximum static inspiratory and expiratory pressures with different lung volumes
Lausted, Christopher G; Johnson, Arthur T; Scott, William H; Johnson, Monique M; Coyne, Karen M; Coursey, Derya C
2006-01-01
Background Maximum pressures developed by the respiratory muscles can indicate the health of the respiratory system, help to determine maximum respiratory flow rates, and contribute to respiratory power development. Past measurements of maximum pressures have been found to be inadequate for inclusion in some exercise models involving respiration. Methods Maximum inspiratory and expiratory airway pressures were measured over a range of lung volumes in 29 female and 19 male adults. A commercial bell spirometry system was programmed to occlude airflow at nine target lung volumes ranging from 10% to 90% of vital capacity. Results In women, maximum expiratory pressure increased with volume from 39 to 61 cmH2O and maximum inspiratory pressure decreased with volume from 66 to 28 cmH2O. In men, maximum expiratory pressure increased with volume from 63 to 97 cmH2O and maximum inspiratory pressure decreased with volume from 97 to 39 cmH2O. Equations describing pressures for both sexes are: Pe/Pmax = 0.1426 Ln( %VC) + 0.3402 R2 = 0.95 Pi/Pmax = 0.234 Ln(100 - %VC) - 0.0828 R2 = 0.96 Conclusion These results were found to be consistent with values and trends obtained by other authors. Regression equations may be suitable for respiratory mechanics models. PMID:16677384
Electroproduction of ϕ(1020) mesons at 1.4⩽Q2⩽3.8 GeV2 measured with the CLAS spectrometer
NASA Astrophysics Data System (ADS)
Santoro, J. P.; Smith, E. S.; Garçon, M.; Guidal, M.; Laget, J. M.; Weiss, C.; Adams, G.; Amaryan, M. J.; Anghinolfi, M.; Asryan, G.; Audit, G.; Avakian, H.; Bagdasaryan, H.; Baillie, N.; Ball, J.; Ball, J. P.; Baltzell, N. A.; Barrow, S.; Battaglieri, M.; Bedlinskiy, I.; Bektasoglu, M.; Bellis, M.; Benmouna, N.; Berman, B. L.; Biselli, A. S.; Blaszczyk, L.; Bonner, B. E.; Bookwalter, C.; Bouchigny, S.; Boiarinov, S.; Bradford, R.; Branford, D.; Briscoe, W. J.; Brooks, W. K.; Bültmann, S.; Burkert, V. D.; Butuceanu, C.; Calarco, J. R.; Careccia, S. L.; Carman, D. S.; Casey, L.; Cazes, A.; Chen, S.; Cheng, L.; Cole, P. L.; Collins, P.; Coltharp, P.; Cords, D.; Corvisiero, P.; Crabb, D.; Crannell, H.; Crede, V.; Cummings, J. P.; Dale, D.; Dashyan, N.; de Masi, R.; de Sanctis, E.; de Vita, R.; Degtyarenko, P. V.; Denizli, H.; Dennis, L.; Deur, A.; Dhamija, S.; Dharmawardane, K. V.; Dhuga, K. S.; Dickson, R.; Djalali, C.; Dodge, G. E.; Doughty, D.; Dugger, M.; Dytman, S.; Dzyubak, O. P.; Egiyan, H.; Egiyan, K. S.; El Fassi, L.; Elouadrhiri, L.; Eugenio, P.; Fatemi, R.; Fedotov, G.; Feuerbach, R. J.; Ficenec, J.; Forest, T. A.; Fradi, A.; Funsten, H.; Gavalian, G.; Gevorgyan, N.; Gilfoyle, G. P.; Giovanetti, K. L.; Girod, F. X.; Goetz, J. T.; Gohn, W.; Gordon, C. I. O.; Gothe, R. W.; Graham, L.; Griffioen, K. A.; Guillo, M.; Guler, N.; Guo, L.; Gyurjyan, V.; Hadjidakis, C.; Hafidi, K.; Hakobyan, H.; Hanretty, C.; Hardie, J.; Hassall, N.; Heddle, D.; Hersman, F. W.; Hicks, K.; Hleiqawi, I.; Holtrop, M.; Hyde-Wright, C. E.; Ilieva, Y.; Ireland, D. G.; Ishkhanov, B. S.; Isupov, E. L.; Ito, M. M.; Jenkins, D.; Jo, H. S.; Johnstone, J. R.; Joo, K.; Juengst, H. G.; Kalantarians, N.; Keller, D.; Kellie, J. D.; Khandaker, M.; Kim, W.; Klein, A.; Klein, F. J.; Klimenko, A. V.; Kossov, M.; Krahn, Z.; Kramer, L. H.; Kubarovsky, V.; Kuhn, J.; Kuhn, S. E.; Kuleshov, S. V.; Kuznetsov, V.; Lachniet, J.; Langheinrich, J.; Lawrence, D.; Li, Ji; Livingston, K.; Lu, H. Y.; MacCormick, M.; Marchand, C.; Markov, N.; Mattione, P.; McAleer, S.; McKinnon, B.; McNabb, J. W. C.; Mecking, B. A.; Mehrabyan, S.; Melone, J. J.; Mestayer, M. D.; Meyer, C. A.; Mibe, T.; Mikhailov, K.; Minehart, R.; Mirazita, M.; Miskimen, R.; Mokeev, V.; Morand, L.; Moreno, B.; Moriya, K.; Morrow, S. A.; Moteabbed, M.; Mueller, J.; Munevar, E.; Mutchler, G. S.; Nadel-Turonski, P.; Nasseripour, R.; Niccolai, S.; Niculescu, G.; Niculescu, I.; Niczyporuk, B. B.; Niroula, M. R.; Niyazov, R. A.; Nozar, M.; O'Rielly, G. V.; Osipenko, M.; Ostrovidov, A. I.; Park, K.; Park, S.; Pasyuk, E.; Paterson, C.; Pereira, S. Anefalos; Philips, S. A.; Pierce, J.; Pivnyuk, N.; Pocanic, D.; Pogorelko, O.; Popa, I.; Pozdniakov, S.; Preedom, B. M.; Price, J. W.; Procureur, S.; Prok, Y.; Protopopescu, D.; Qin, L. M.; Raue, B. A.; Riccardi, G.; Ricco, G.; Ripani, M.; Ritchie, B. G.; Rosner, G.; Rossi, P.; Sabatié, F.; Saini, M. S.; Salamanca, J.; Salgado, C.; Sapunenko, V.; Schott, D.; Schumacher, R. A.; Serov, V. S.; Sharabian, Y. G.; Sharov, D.; Shvedunov, N. V.; Skabelin, A. V.; Smith, L. C.; Sober, D. I.; Sokhan, D.; Stavinsky, A.; Stepanyan, S. S.; Stepanyan, S.; Stokes, B. E.; Stoler, P.; Strakovsky, I. I.; Strauch, S.; Taiuti, M.; Tedeschi, D. J.; Tkabladze, A.; Tkachenko, S.; Todor, L.; Tur, C.; Ungaro, M.; Vineyard, M. F.; Vlassov, A. V.; Watts, D. P.; Weinstein, L. B.; Weygand, D. P.; Williams, M.; Wolin, E.; Wood, M. H.; Yegneswaran, A.; Yurov, M.; Zana, L.; Zhang, J.; Zhao, B.; Zhao, Z. W.
2008-08-01
Electroproduction of exclusive ϕ vector mesons has been studied with the CLAS detector in the kinematic range 1.4⩽Q2⩽3.8 GeV2,0.0⩽t'⩽3.6 GeV2, and 2.0⩽W⩽3.0 GeV. The scaling exponent for the total cross section as 1/(Q2+Mϕ2)n was determined to be n=2.49±0.33. The slope of the four-momentum transfer t' distribution is bϕ=0.98±0.17 GeV-2. Under the assumption of s-channel helicity conservation, we determine the ratio of longitudinal to transverse cross sections to be R=0.86±0.24. A two-gluon exchange model is able to reproduce the main features of the data.
2006-06-01
ψ ρ ψ = = − ∑ ∫ (32) The last integral in Equation (29), mnH has the form 20 ( ) ( )( ) ( ) 0 2 ( , ) sin 2 ( ) 2 mn mn R i l k r mn i l k R mn...should be noted that in evaluating mnH , it is assumed that R is very large and that both the initial point 0r = and the final range R are well
Peng, Guilong; He, Qiang; Lu, Ying; Mmereki, Daniel; Zhong, Zhihui
2016-10-01
A simple method based on dispersive solid-phase extraction (DSPE) and dispersive liquid-liquid microextraction method based on solidification of floating organic droplets (DLLME-SFO) was developed for the extraction of chlorpyrifos (CP), chlorpyrifos-methyl (CPM), and their main degradation product 3,5,6-trichloro-2-pyridinol (TCP) in tomato and cucumber samples. The determination was carried out by high performance liquid chromatography with ultraviolet detection (HPLC-UV). In the DSPE-DLLME-SFO, the analytes were first extracted with acetone. The clean-up of the extract by DSPE was carried out by directly adding activated carbon sorbent into the extract solution, followed by shaking and filtration. Under the optimum conditions, the proposed method was sensitive and showed a good linearity within a range of 2-500 ng/g, with the correlation coefficients (r) varying from 0.9991 to 0.9996. The enrichment factors ranged from 127 to 138. The limit of detections (LODs) were in the range of 0.12-0.68 ng/g, and the relative standard deviations (RSDs) for 50 ng/g of each analytes in tomato samples were in the range of 3.25-6.26 % (n = 5). The proposed method was successfully applied for the extraction and determination of the mentioned analytes residues in tomato and cucumber samples, and satisfactory results were obtained.
Heritability of lenticular myopia in English Springer spaniels.
Kubai, Melissa A; Labelle, Amber L; Hamor, Ralph E; Mutti, Donald O; Famula, Thomas R; Murphy, Christopher J
2013-11-08
We determined whether naturally-occurring lenticular myopia in English Springer spaniels (ESS) has a genetic component. Streak retinoscopy was performed on 226 related ESS 30 minutes after the onset of pharmacologic mydriasis and cycloplegia. A pedigree was constructed to determine relationships between affected offspring and parents. Estimation of heritability was done in a Bayesian analysis (facilitated by the MCMCglmm package of R) of refractive error in a model, including terms for sex and coat color. Myopia was defined as ≤-0.5 diopters (D) spherical equivalent. The median refractive error for ESS was 0.25 D (range, -3.5 to +4.5 D). Median age was 0.2 years (range, 0.1-15 years). The prevalence of myopia in related ESS was 19% (42/226). The ESS had a strong correlation (r = 0.95) for refractive error between the two eyes. Moderate heritability was present for refractive error with a mean value of 0.29 (95% highest probability density, 0.07-0.50). The distribution of refractive error, and subsequently lenticular myopia, has a moderate genetic component in ESS. Further investigation of genes responsible for regulation of the development of refractive ocular components in canines is warranted.
Triclosan resistant bacteria in sewage effluent and cross-resistance to antibiotics.
Coetzee, I; Bezuidenhout, C C; Bezuidenhout, J J
2017-09-01
The purpose of this study was to identify triclosan tolerant heterotrophic plate count (HPC) bacteria from sewage effluent and to determine cross-resistance to antibiotics. R2 agar supplemented with triclosan was utilised to isolate triclosan resistant bacteria and 16S rRNA gene sequencing was conducted to identify the isolates. Minimum inhibitory concentrations (MICs) of organisms were determined at selected concentrations of triclosan and cross-resistance to various antibiotics was performed. High-performance liquid chromatography was conducted to quantify levels of triclosan in sewage water. Forty-four HPC were isolated and identified as the five main genera, namely, Bacillus, Pseudomonas, Enterococcus, Brevibacillus and Paenibacillus. MIC values of these isolates ranged from 0.125 mg/L to >1 mg/L of triclosan, while combination of antimicrobials indicated synergism or antagonism. Levels of triclosan within the wastewater treatment plant (WWTP) ranged between 0.026 and 1.488 ppb. Triclosan concentrations were reduced by the WWTP, but small concentrations enter receiving freshwater bodies. Results presented indicate that these levels are sufficient to maintain triclosan resistant bacteria under controlled conditions. Further studies are thus needed into the impact of this scenario on such natural receiving water bodies.
A new method for estimating UV fluxes at ground level in cloud-free conditions
NASA Astrophysics Data System (ADS)
Wandji Nyamsi, William; Pitkänen, Mikko R. A.; Aoun, Youva; Blanc, Philippe; Heikkilä, Anu; Lakkala, Kaisa; Bernhard, Germar; Koskela, Tapani; Lindfors, Anders V.; Arola, Antti; Wald, Lucien
2017-12-01
A new method has been developed to estimate the global and direct solar irradiance in the UV-A and UV-B at ground level in cloud-free conditions. It is based on a resampling technique applied to the results of the k-distribution method and the correlated-k approximation of Kato et al. (1999) over the UV band. Its inputs are the aerosol properties and total column ozone that are produced by the Copernicus Atmosphere Monitoring Service (CAMS). The estimates from this new method have been compared to instantaneous measurements of global UV irradiances made in cloud-free conditions at five stations at high latitudes in various climates. For the UV-A irradiance, the bias ranges between -0.8 W m-2 (-3 % of the mean of all data) and -0.2 W m-2 (-1 %). The root mean square error (RMSE) ranges from 1.1 W m-2 (6 %) to 1.9 W m-2 (9 %). The coefficient of determination R2 is greater than 0.98. The bias for UV-B is between -0.04 W m-2 (-4 %) and 0.08 W m-2 (+13 %) and the RMSE is 0.1 W m-2 (between 12 and 18 %). R2 ranges between 0.97 and 0.99. This work demonstrates the quality of the proposed method combined with the CAMS products. Improvements, especially in the modeling of the reflectivity of the Earth's surface in the UV region, are necessary prior to its inclusion into an operational tool.