Sample records for determined results compared

  1. Deciphering the link between doubly uniparental inheritance of mtDNA and sex determination in bivalves: Clues from comparative transcriptomics

    USGS Publications Warehouse

    Capt, Charlotte; Renaut, Sébastien; Ghiselli, Fabrizio; Milani, Liliana; Johnson, Nathan A.; Sietman, Bernard E.; Stewart, Donald; Breton, Sophie

    2018-01-01

    Bivalves exhibit an astonishing diversity of sexual systems and sex-determining mechanisms. They can be gonochoric, hermaphroditic or androgenetic, with both genetic and environmental factors known to determine or influence sex. One unique sex-determining system involving the mitochondrial genome has also been hypothesized to exist in bivalves with doubly uniparental inheritance (DUI) of mtDNA. However, the link between DUI and sex determination remains obscure. In this study, we performed a comparative gonad transcriptomics analysis for two DUI-possessing freshwater mussel species to better understand the mechanisms underlying sex determination and DUI in these bivalves. We used a BLAST reciprocal analysis to identify orthologs between Venustaconcha ellipsiformis and Utterbackia peninsularis and compared our results with previously published sex-specific bivalve transcriptomes to identify conserved sex-determining genes. We also compared our data with other DUI species to identify candidate genes possibly involved in the regulation of DUI. A total of ∼12,000 orthologous relationships were found, with 2,583 genes differentially expressed in both species. Among these genes, key sex-determining factors previously reported in vertebrates and in bivalves (e.g., Sry, Dmrt1, Foxl2) were identified, suggesting that some steps of the sex-determination pathway may be deeply conserved in metazoans. Our results also support the hypothesis that a modified ubiquitination mechanism could be responsible for the retention of the paternal mtDNA in male bivalves, and revealed that DNA methylation could also be involved in the regulation of DUI. Globally, our results suggest that sets of genes associated with sex determination and DUI are similar in distantly-related DUI species.

  2. Deciphering the Link between Doubly Uniparental Inheritance of mtDNA and Sex Determination in Bivalves: Clues from Comparative Transcriptomics.

    PubMed

    Capt, Charlotte; Renaut, Sébastien; Ghiselli, Fabrizio; Milani, Liliana; Johnson, Nathan A; Sietman, Bernard E; Stewart, Donald T; Breton, Sophie

    2018-02-01

    Bivalves exhibit an astonishing diversity of sexual systems and sex-determining mechanisms. They can be gonochoric, hermaphroditic or androgenetic, with both genetic and environmental factors known to determine or influence sex. One unique sex-determining system involving the mitochondrial genome has also been hypothesized to exist in bivalves with doubly uniparental inheritance (DUI) of mtDNA. However, the link between DUI and sex determination remains obscure. In this study, we performed a comparative gonad transcriptomics analysis for two DUI-possessing freshwater mussel species to better understand the mechanisms underlying sex determination and DUI in these bivalves. We used a BLAST reciprocal analysis to identify orthologs between Venustaconcha ellipsiformis and Utterbackia peninsularis and compared our results with previously published sex-specific bivalve transcriptomes to identify conserved sex-determining genes. We also compared our data with other DUI species to identify candidate genes possibly involved in the regulation of DUI. A total of ∼12,000 orthologous relationships were found, with 2,583 genes differentially expressed in both species. Among these genes, key sex-determining factors previously reported in vertebrates and in bivalves (e.g., Sry, Dmrt1, Foxl2) were identified, suggesting that some steps of the sex-determination pathway may be deeply conserved in metazoans. Our results also support the hypothesis that a modified ubiquitination mechanism could be responsible for the retention of the paternal mtDNA in male bivalves, and revealed that DNA methylation could also be involved in the regulation of DUI. Globally, our results suggest that sets of genes associated with sex determination and DUI are similar in distantly-related DUI species. © The Author(s) 2018. Published by Oxford University Press on behalf of the Society for Molecular Biology and Evolution.

  3. Deciphering the Link between Doubly Uniparental Inheritance of mtDNA and Sex Determination in Bivalves: Clues from Comparative Transcriptomics

    PubMed Central

    Renaut, Sébastien; Milani, Liliana; Johnson, Nathan A; Sietman, Bernard E; Stewart, Donald T

    2018-01-01

    Abstract Bivalves exhibit an astonishing diversity of sexual systems and sex-determining mechanisms. They can be gonochoric, hermaphroditic or androgenetic, with both genetic and environmental factors known to determine or influence sex. One unique sex-determining system involving the mitochondrial genome has also been hypothesized to exist in bivalves with doubly uniparental inheritance (DUI) of mtDNA. However, the link between DUI and sex determination remains obscure. In this study, we performed a comparative gonad transcriptomics analysis for two DUI-possessing freshwater mussel species to better understand the mechanisms underlying sex determination and DUI in these bivalves. We used a BLAST reciprocal analysis to identify orthologs between Venustaconcha ellipsiformis and Utterbackia peninsularis and compared our results with previously published sex-specific bivalve transcriptomes to identify conserved sex-determining genes. We also compared our data with other DUI species to identify candidate genes possibly involved in the regulation of DUI. A total of ∼12,000 orthologous relationships were found, with 2,583 genes differentially expressed in both species. Among these genes, key sex-determining factors previously reported in vertebrates and in bivalves (e.g., Sry, Dmrt1, Foxl2) were identified, suggesting that some steps of the sex-determination pathway may be deeply conserved in metazoans. Our results also support the hypothesis that a modified ubiquitination mechanism could be responsible for the retention of the paternal mtDNA in male bivalves, and revealed that DNA methylation could also be involved in the regulation of DUI. Globally, our results suggest that sets of genes associated with sex determination and DUI are similar in distantly-related DUI species. PMID:29360964

  4. Comparative carcinogenic potencies of particulates from diesel engine exhausts, coke oven emissions, roofing tar aerosols and cigarette smoke.

    PubMed Central

    Albert, R E

    1983-01-01

    Mammalian cell mutagenesis, transformation and skin tumorigenesis assays show similar results in comparing the potencies of diesel, coke oven, roofing tar and cigarette smoke particulates. These assay results are reasonably consistent with the comparative carcinogenic potencies of coke oven and roofing tar emissions as determined by epidemiological studies. The bacterial mutagenesis assay tends to show disproportionately high potencies, particularly with diesel particulates. Results to date encourage the approach to the assessment for carcinogenic risks from diesel emissions based on the use of epidemiological data on cancer induced by coke oven emissions, roofing tar particulates and cigarette smoke with the comparative potencies of these materials determined by in vivo and in vitro bioassays. PMID:6186481

  5. Comparative study of landslides susceptibility mapping methods: Multi-Criteria Decision Making (MCDM) and Artificial Neural Network (ANN)

    NASA Astrophysics Data System (ADS)

    Salleh, S. A.; Rahman, A. S. A. Abd; Othman, A. N.; Mohd, W. M. N. Wan

    2018-02-01

    As different approach produces different results, it is crucial to determine the methods that are accurate in order to perform analysis towards the event. This research aim is to compare the Rank Reciprocal (MCDM) and Artificial Neural Network (ANN) analysis techniques in determining susceptible zones of landslide hazard. The study is based on data obtained from various sources such as local authority; Dewan Bandaraya Kuala Lumpur (DBKL), Jabatan Kerja Raya (JKR) and other agencies. The data were analysed and processed using Arc GIS. The results were compared by quantifying the risk ranking and area differential. It was also compared with the zonation map classified by DBKL. The results suggested that ANN method gives better accuracy compared to MCDM with 18.18% higher accuracy assessment of the MCDM approach. This indicated that ANN provides more reliable results and it is probably due to its ability to learn from the environment thus portraying realistic and accurate result.

  6. [A comparative evaluation of the methods for determining nitrogen dioxide in an industrial environment].

    PubMed

    Panev, T

    1991-01-01

    The present work has the purpose to make a comparative evaluation of the different types detector tubes--for analysis, long-term and passive for determination of NO2 and the results to be compared, with those received by the spectrophotometric method and the reagent of Zaltsman. Studies were performed in the hall of the garage for repair of diesel buses during one working shift. The results point out that the analysing tubes for NO2 give good results with the spectrophotometric method. The measured average-shift concentrations of NO2 by long-term and passive tubes are juxtaposed with the average-received values with the analytical tubes and with the analytical method.

  7. Determination of Elastic Moduli of Fiber-Resin Composites Using an Impulse Excitation Technique

    NASA Technical Reports Server (NTRS)

    Viens, Michael J.; Johnson, Jeffrey J.

    1996-01-01

    The elastic moduli of graphite/epoxy and graphite/cyanate ester composite specimens with various laminate lay-ups was determined using an impulse excitation/acoustic resonance technique and compared to those determined using traditional strain gauge and extensometer techniques. The stiffness results were also compared to those predicted from laminate theory using uniaxial properties. The specimen stiffnesses interrogated ranged from 12 to 30 Msi. The impulse excitation technique was found to be a relatively quick and accurate method for determining elastic moduli with minimal specimen preparation and no requirement for mechanical loading frames. The results of this investigation showed good correlation between the elastic modulus determined using the impulse excitation technique, strain gauge and extensometer techniques, and modulus predicted from laminate theory. The flexural stiffness determined using the impulse excitation was in good agreement with that predicted from laminate theory. The impulse excitation/acoustic resonance interrogation technique has potential as a quality control test.

  8. Evaluation of mesoporous silicon thermal conductivity by electrothermal finite element simulation

    PubMed Central

    2012-01-01

    The aim of this work is to determine the thermal conductivity of mesoporous silicon (PoSi) by fitting the experimental results with simulated ones. The electrothermal response (resistance versus applied current) of differently designed test lines integrated onto PoSi/silicon substrates and the bulk were compared to the simulations. The PoSi thermal conductivity was the single parameter used to fit the experimental results. The obtained thermal conductivity values were compared with those determined from Raman scattering measurements, and a good agreement between both methods was found. This methodology can be used to easily determine the thermal conductivity value for various porous silicon morphologies. PMID:22849851

  9. Hydrocarbon group type determination in jet fuels by high performance liquid chromatography

    NASA Technical Reports Server (NTRS)

    Antoine, A. C.

    1977-01-01

    Thirty-two jet and diesel fuel samples of varying chemical composition and physical properties were prepared from oil shale and coal syncrudes. Hydrocarbon types in these samples were determined by a fluorescent indicator adsorption analysis, and the results from three laboratories are presented and compared. Two methods of rapid high performance liquid chromatography were used to analyze some of the samples, and these results are also presented and compared. Two samples of petroleum-based Jet A fuel are similarly analyzed.

  10. Determination of JWL Parameters for Non-Ideal Explosive

    NASA Astrophysics Data System (ADS)

    Hamashima, H.; Kato, Y.; Itoh, S.

    2004-07-01

    JWL equation of state is widely used in numerical simulation of detonation phenomena. JWL parameters are determined by cylinder test. Detonation characteristics of non-ideal explosive depend strongly on confinement, and JWL parameters determined by cylinder test do not represent the state of detonation products in many applications. We developed a method to determine JWL parameters from the underwater explosion test. JWL parameters were determined through a method of characteristics applied to the configuration of the underwater shock waves of cylindrical explosives. The numerical results obtained using JWL parameters determined by the underwater explosion test and those obtained using JWL parameters determined by cylinder test were compared with experimental results for typical non-ideal explosive; emulsion explosive. Good agreement was confirmed between the results obtained using JWL parameters determined by the underwater explosion test and experimental results.

  11. Determination of low methylmercury concentrations in peat soil samples by isotope dilution GC-ICP-MS using distillation and solvent extraction methods.

    PubMed

    Pietilä, Heidi; Perämäki, Paavo; Piispanen, Juha; Starr, Mike; Nieminen, Tiina; Kantola, Marjatta; Ukonmaanaho, Liisa

    2015-04-01

    Most often, only total mercury concentrations in soil samples are determined in environmental studies. However, the determination of extremely toxic methylmercury (MeHg) in addition to the total mercury is critical to understand the biogeochemistry of mercury in the environment. In this study, N2-assisted distillation and acidic KBr/CuSO4 solvent extraction methods were applied to isolate MeHg from wet peat soil samples collected from boreal forest catchments. Determination of MeHg was performed using a purge and trap GC-ICP-MS technique with a species-specific isotope dilution quantification. Distillation is known to be more prone to artificial MeHg formation compared to solvent extraction which may result in the erroneous MeHg results, especially with samples containing high amounts of inorganic mercury. However, methylation of inorganic mercury during the distillation step had no effect on the reliability of the final MeHg results when natural peat soil samples were distilled. MeHg concentrations determined in peat soil samples after distillation were compared to those determined after the solvent extraction method. MeHg concentrations in peat soil samples varied from 0.8 to 18 μg kg(-1) (dry weight) and the results obtained with the two different methods did not differ significantly (p=0.05). The distillation method with an isotope dilution GC-ICP-MS was shown to be a reliable method for the determination of low MeHg concentrations in unpolluted soil samples. Furthermore, the distillation method is solvent-free and less time-consuming and labor-intensive when compared to the solvent extraction method. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. 76 FR 43287 - Building Energy Standards Program: Determination Regarding Energy Efficiency Improvements in the...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-20

    ... determined that the quantitative analysis of the energy consumption of buildings built to Standard 90.1-2007... Determination 3. Public Comments Regarding the Preliminary Determination II. Summary of the Comparative Analysis... Analysis B. Quantitative Analysis 1. Discussion of Whole Building Energy Analysis 2. Results of Whole...

  13. A Comparable Worth Cyclone Is Swirling toward Your Schools.

    ERIC Educational Resources Information Center

    Zakariya, Sally Banks

    1985-01-01

    Describes the concept of comparable worth, discusses opposing views concerning whether inequities in pay are results of discrimination, considers efforts to determine the comparability of jobs, including teaching, notes the possible impact of implementing comparable worth legislation, and cites developments in state legislation and local school…

  14. Storage Capacity and Sedimentation of Loch Lomond Reservoir, Santa Cruz, California, 1998

    USGS Publications Warehouse

    McPherson, Kelly R.; Harmon, Jerry G.

    2000-01-01

    In 1998, a bathymetric survey was done to determine the storage capacity and the loss of capacity owing to sedimentation of Loch Lomond Reservoir in Santa Cruz County, California. Results of the survey indicate that the maximum capacity of the reservoir is 8,991 acre-feet in November 1998. The results of previous investigations indicate that storage capacity of the reservoir is less than 8,991 acre-feet. The storage capacity determined from those investigations probably were underestimated because of limitations of the methods and the equipment used. The volume of sedimentation in a reservoir is considered equal to the decrease in storage capacity. To determine sedimentation in Loch Lomond Reservoir, change in storage capacity was estimated for an upstream reach of the reservoir. The change in storage capacity was determined by comparing a 1998 thalweg profile (valley floor) of the reservoir with thalweg profiles from previous investigations; results of the comparison indicate that sedimentation is occurring in the upstream reach. Cross sections for 1998 and 1982 were compared to determine the magnitude of sedimentation in the upstream reach of the reservoir. Results of the comparison, which were determined from changes in the cross-sectional areas, indicate that the capacity of the reservoir decreased by 55 acre-feet.

  15. Retinal injury resulting from simultaneous exposure to radiation from two lasers with different wavelengths

    NASA Astrophysics Data System (ADS)

    Stolarski, David J.; Cain, Clarence P.; Schuster, Kurt J.; Imholte, Michelle; Carothers, Val C.; Buffington, Gavin D.; Edwards, Michael; Thomas, Robert J.; Rockwell, Benjamin A.

    2005-04-01

    To assess the retinal hazards related to simultaneous exposure from two lasers of separate wavelengths, the retinal effects of 5-second laser irradiation from 532 nm and 647 nm were determined in non-human primates. A total of six eyes were exposed using equal amounts of power to determine the damage levels. The results were combined with those of previous, two-wavelength studies done by our group and compared to damage models developed in our lab. The data were also compared to the calculations resulting from use of the currently accepted method of predicting hazards from simultaneous lasing.

  16. Finding a Comparison Group: Is Online Crowdsourcing a Viable Option?

    ERIC Educational Resources Information Center

    Azzam, Tarek; Jacobson, Miriam R.

    2013-01-01

    This article explores the viability of online crowdsourcing for creating matched-comparison groups. This exploratory study compares survey results from a randomized control group to survey results from a matched-comparison group created from Amazon.com's MTurk crowdsourcing service to determine their comparability. Study findings indicate…

  17. Characterization of fatigue properties of binders and mastics at intermediate temperatures using dynamic shear rheometer.

    DOT National Transportation Integrated Search

    2013-10-01

    The paper compares the fatigue life of neat and modified PAV-aged binders and mastics and : determines the influence of dust on fatigue life using the Linear Amplitude Sweep (LAS) method. It : will also compare these results with results from the DER...

  18. Comparative study between ultrasonography and optical coherence tomography in interventional cardiology

    NASA Astrophysics Data System (ADS)

    Fanjul-Vélez, Félix; de la Torre-Hernández, José María; Ortega-Quijano, Noé; Zueco-Gil, José Javier; Arce-Diego, José Luis

    2009-07-01

    In this work, we present clinical images of IVUS and OCT in the evaluation of pharmacological stent endothelization. These preliminary imaging results are analyzed and compared in order to determine the ability of these technologies to visualize relevant intravascular features of interest in interventional cardiology. The results enable to compare the performance of both techniques and to evaluate their potential for clinical purposes.

  19. Three dimensional (3D) microstructure-based finite element modeling of Al-SiC nanolaminates using focused ion beam (FIB) tomography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mayer, Carl R.

    Al-SiC nanolaminate composites show promise as high performance coating materials due to their combination of strength and toughness. Although a significant amount of modeling effort has been focused on materials with an idealized flat nanostructure, experimentally these materials exhibit complex undulating layer geometries. This work utilizes FIB tomography to characterize this nanostructure in 3D and finite element modeling to determine the effect that this complex structure has on the mechanical behavior of these materials. A sufficiently large volume was characterized such that a 1 × 2 μm micropillar could be generated from the dataset and compared directly to experimental results.more » The mechanical response from this nanostructure was then compared to pillar models using simplified structures with perfectly flat layers, layers with sinusoidal waviness, and layers with arc segment waviness. The arc segment based layer geometry showed the best agreement with the experimentally determined structure, indicating it would be the most appropriate geometry for future modeling efforts. - Highlights: •FIB tomography was used to determine the structure of an Al-SiC nanolaminate in 3D. •FEM was used to compare the deformation of the nanostructure to experimental results. •Idealized structures from literature were compared to the FIB determined structure. •Arc segment based structures approximated the FIB determined structure most closely.« less

  20. Verifying speculative multithreading in an application

    DOEpatents

    Felton, Mitchell D

    2014-12-09

    Verifying speculative multithreading in an application executing in a computing system, including: executing one or more test instructions serially thereby producing a serial result, including insuring that all data dependencies among the test instructions are satisfied; executing the test instructions speculatively in a plurality of threads thereby producing a speculative result; and determining whether a speculative multithreading error exists including: comparing the serial result to the speculative result and, if the serial result does not match the speculative result, determining that a speculative multithreading error exists.

  1. Verifying speculative multithreading in an application

    DOEpatents

    Felton, Mitchell D

    2014-11-18

    Verifying speculative multithreading in an application executing in a computing system, including: executing one or more test instructions serially thereby producing a serial result, including insuring that all data dependencies among the test instructions are satisfied; executing the test instructions speculatively in a plurality of threads thereby producing a speculative result; and determining whether a speculative multithreading error exists including: comparing the serial result to the speculative result and, if the serial result does not match the speculative result, determining that a speculative multithreading error exists.

  2. The impact of chimerism in DNA-based forensic sex determination analysis.

    PubMed

    George, Renjith; Donald, Preethy Mary; Nagraj, Sumanth Kumbargere; Idiculla, Jose Joy; Hj Ismail, Rashid

    2013-01-01

    Sex determination is the most important step in personal identification in forensic investigations. DNA-based sex determination analysis is comparatively more reliable than the other conventional methods of sex determination analysis. Advanced technology like real-time polymerase chain reaction (PCR) offers accurate and reproducible results and is at the level of legal acceptance. But still there are situations like chimerism where an individual possess both male and female specific factors together in their body. Sex determination analysis in such cases can give erroneous results. This paper discusses the phenomenon of chimerism and its impact on sex determination analysis in forensic investigations.

  3. Improved solution accuracy for Landsat-4 (TDRSS-user) orbit determination

    NASA Technical Reports Server (NTRS)

    Oza, D. H.; Niklewski, D. J.; Doll, C. E.; Mistretta, G. D.; Hart, R. C.

    1994-01-01

    This paper presents the results of a study to compare the orbit determination accuracy for a Tracking and Data Relay Satellite System (TDRSS) user spacecraft, Landsat-4, obtained using a Prototype Filter Smoother (PFS), with the accuracy of an established batch-least-squares system, the Goddard Trajectory Determination System (GTDS). The results of Landsat-4 orbit determination will provide useful experience for the Earth Observing System (EOS) series of satellites. The Landsat-4 ephemerides were estimated for the January 17-23, 1991, timeframe, during which intensive TDRSS tracking data for Landsat-4 were available. Independent assessments were made of the consistencies (overlap comparisons for the batch case and convariances for the sequential case) of solutions produced by the batch and sequential methods. The filtered and smoothed PFS orbit solutions were compared with the definitive GTDS orbit solutions for Landsat-4; the solution differences were generally less than 15 meters.

  4. Extractive-spectrophotometric determination of disopyramide and irbesartan in their pharmaceutical formulation

    NASA Astrophysics Data System (ADS)

    Abdellatef, Hisham E.

    2007-04-01

    Picric acid, bromocresol green, bromothymol blue, cobalt thiocyanate and molybdenum(V) thiocyanate have been tested as spectrophotometric reagents for the determination of disopyramide and irbesartan. Reaction conditions have been optimized to obtain coloured comoplexes of higher sensitivity and longer stability. The absorbance of ion-pair complexes formed were found to increases linearity with increases in concentrations of disopyramide and irbesartan which were corroborated by correction coefficient values. The developed methods have been successfully applied for the determination of disopyramide and irbesartan in bulk drugs and pharmaceutical formulations. The common excipients and additives did not interfere in their determination. The results obtained by the proposed methods have been statistically compared by means of student t-test and by the variance ratio F-test. The validity was assessed by applying the standard addition technique. The results were compared statistically with the official or reference methods showing a good agreement with high precision and accuracy.

  5. Piezoceramic Actuator Placement for Acoustic Control of Panels

    NASA Technical Reports Server (NTRS)

    Bevan, Jeffrey S.; Turner, Travis L. (Technical Monitor)

    2001-01-01

    Optimum placement of multiple traditional piezoceramic actuators is determined for active structural acoustic control of flat panels. The structural acoustic response is determined using acoustic radiation filters and structural surface vibration characteristics. Linear Quadratic Regulator (LQR) control is utilized to determine the optimum state feedback gain for active structural acoustic control. The optimum actuator location is determined by minimizing the structural acoustic radiated noise using a modified genetic algorithm. Experimental tests are conducted and compared to analytical results. Anisotropic piezoceramic actuators exhibits enhanced performance when compared to traditional isotropic piezoceramic actuators. As a result of the inherent isotropy, these advanced actuators develop strain along the principal material axis. The orientation of anisotropic actuators is investigated on the effect of structural vibration and acoustic control of curved and flat panels. A fully coupled shallow shell finite element formulation is developed to include anisotropic piezoceramic actuators for shell structures.

  6. Piezoceramic Actuator Placement for Acoustic Control of Panels

    NASA Technical Reports Server (NTRS)

    Bevan, Jeffrey S.

    2000-01-01

    Optimum placement of multiple traditional piezoceramic actuators is determined for active structural acoustic control of flat panels. The structural acoustic response is determined using acoustic radiation filters and structural surface vibration characteristics. Linear Quadratic Regulator (LQR) control is utilized to determine the optimum state feedback gain for active structural acoustic control. The optimum actuator location is determined by minimizing the structural acoustic radiated noise using a modified genetic algorithm. Experimental tests are conducted and compared to analytical results. Anisotropic piezoceramic actuators exhibit enhanced performance when compared to traditional isotropic piezoceramic actuators. As a result of the inherent isotropy, these advanced actuators develop strain along the principal material axis. The orientation of anisotropic actuators is investigated on the effect of structural vibration and acoustic control of curved and flat panels. A fully coupled shallow shell finite element formulation is developed to include anisotropic piezoceramic actuators for shell structures.

  7. Computerized tomographic determination of spinal bone mineral content

    NASA Technical Reports Server (NTRS)

    Cann, C. E.; Genant, H. K.

    1980-01-01

    The aims of the study were three-fold: to determine the magnitude of vertebral cancellous mineral loss in normal subjects during bedrest, to compare this loss with calcium balance and mineral loss in peripheral bones, and to use the vertebral measurements as an evaluative criterion for the C12MDP treatment and compare it with other methods. The methods used are described and the results from 14 subjects are presented.

  8. Comparing composts formed by different technological processing

    NASA Astrophysics Data System (ADS)

    Lyckova, B.; Mudrunka, J.; Kucerova, R.; Glogarova, V.

    2017-10-01

    The presented article compares quality of composts which were formed by different technological processes. The subject to comparison was a compost which was created in a closed fermenter where ideal conditions for decomposition and organic substances conversion were ensured, with compost which was produced in an open box of community composting. The created composts were analysed to determine whether it is more important for the final compost to comply with the composting conditions or better sorting of raw materials needed for compost production. The results of the carried out experiments showed that quality of the resulting compost cannot be determined unequivocally.

  9. Nomarski differential interference contrast microscopy for surface slope measurements: an examination of techniques

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hartman, J.S.; Gordon, R.L.; Lessor, D.L.

    1981-08-01

    Alternate measurement and data analysis procedures are discussed and compared for the application of reflective Nomarski differential interference contrast microscopy for the determination of surface slopes. The discussion includes the interpretation of a previously reported iterative procedure using the results of a detailed optical model and the presentation of a new procedure based on measured image intensity extrema. Surface slope determinations from these procedures are presented and compared with results from a previously reported curve fit analysis of image intensity data. The accuracy and advantages of the different procedures are discussed.

  10. Cold-air annular-cascade investigation of aerodynamic performance of cooled turbine vanes. 2: Trailing-edge ejection, film cooling, and transpiration cooling

    NASA Technical Reports Server (NTRS)

    Goldman, L. J.; Mclallin, K. L.

    1975-01-01

    The aerodynamic performance of four different cooled vane configurations was experimentally determined in a full-annular cascade at a primary- to coolant-total-temperature ratio of 1.0. The vanes were tested over a range of coolant flow rates and pressure ratios. Overall vane efficiencies were obtained and compared, where possible, with the results obtained in a four-vane, annular-sector cascade. The vane efficiency and exit flow conditions as functions of radial position were also determined and compared with solid (uncooled) vane results.

  11. Flight determined lift and drag characteristics of an F-8 airplane modified with a supercritical wing with comparison to wind-tunnel results

    NASA Technical Reports Server (NTRS)

    Pyle, J. S.; Steers, L. L.

    1975-01-01

    Flight measurements obtained with a TF-8A airplane modified with a supercritical wing are presented for altitudes from 7.6 kilometers (25,000 feet) to 13.7 kilometers (45,000 feet), Mach numbers from 0.6 to 1.2, and Reynolds numbers from 0.8 x 10 to the 7th power to 2.3 x 10 to the 7th power. Flight results for the airplane with and without area-rule fuselage fairings are compared. The techniques used to determine the lift and drag characteristics of the airplane are discussed. Flight data are compared with wind-tunnel model results, where applicable.

  12. Extinction-to-Backscatter Ratios of Lofted Aerosol Layers Observed During the First Three Months of CALIPSO Measurements

    NASA Technical Reports Server (NTRS)

    Omar, Ali H.; Vaughan, Mark A.; Liu, Zhaoyan; Hu, Yongxiang; Reagan, John A.; Winker, David M.

    2007-01-01

    Case studies from the first three months of the Cloud and Aerosol Lidar and Infrared Pathfinder Spaceborne Observations (CALIPSO) measurements of lofted aerosol layers are analyzed using transmittance [Young, 1995] and two-wavelength algorithms [Vaughan et al., 2004] to determine the aerosol extinction-to-backscatter ratios at 532 and 1064 nm. The transmittance method requires clear air below the layer so that the transmittance through the layer can be determined. Suitable scenes are selected from the browse images and clear air below features is identified by low 532 nm backscatter signal and confirmed by low depolarization and color ratios. The transmittance and two-wavelength techniques are applied to a number of lofted layers and the extinction-to-backscatter ratios are compared with values obtained from the CALIPSO aerosol models [Omar et al., 2004]. The results obtained from these studies are used to adjust the aerosol models and develop observations based extinction-to-backscatter ratio look-up tables and phase functions. Values obtained by these techniques are compared to Sa determinations using other independent methods with a goal of developing probability distribution functions of aerosol type-specific extinction to backscatter ratios. In particular, the results are compared to values determined directly by the High Spectral Resolution Lidar (HSRL) during the CALIPSO CloudSat Validation Experiments (CCVEX) and Sa determined by the application of the two-wavelength lidar Constrained Ratio Aerosol Model-fit (CRAM) retrieval approach [Cattrall et al., 2005; Reagan et al., 2004] to the HSRL data. The results are also compared to values derived using the empirical relationship between the multiple-scattering fraction and the linear depolarization ratio by using Monte Carlo simulations of water clouds [Hu et al., 2006].

  13. COMPARING STABLE CARBON ISOTOPE AND RESPIROMETRIC TECHNIQUES FOR EVALUATING BIODEGRADATION

    EPA Science Inventory

    Biodegradation of petrochemical contaminants such as crude oil and polychlorinated biphenyls has been determined to remove these contaminants from the environment. The biological processes that result in the contaminant degradation have been determined primarily through bench-sc...

  14. L-Phenylalanine concentration in blood of phenylketonuria patients: a modified enzyme colorimetric assay compared with amino acid analysis, tandem mass spectrometry, and HPLC methods.

    PubMed

    De Silva, Veronica; Oldham, Charlie D; May, Sheldon W

    2010-09-01

    Phenylketonuria (PKU) is an autosomal recessive disorder caused by an impaired conversion of L-phenylalanine (Phe) to L-tyrosine, typically resulting from a deficiency in activity of a hepatic and renal enzyme L-phenylalanine hydroxylase. The disease is characterized by an increased concentration of Phe and its metabolites in body fluids. A modified assay based on an enzymatic-colorimetric methodology was developed for measuring blood Phe levels in PKU patients; this method is designed for use with undeproteinized samples and avoids the use of solvents or amphiphilic agents. Thus, the method could be suitable for incorporation into a simple home-monitoring device. We report here on a comparison of blood Phe concentrations in PKU patients measured in undeproteinized plasma using this enzyme colorimetric assay (ECA), with values determined by amino acid analysis (AAA) of deproteinized samples, and HPLC and tandem mass spectrometry (MS/MS) analyses of dried blood spot (DBS) eluates. Pearson correlation coefficients of 0.951, 0.976 and 0.988 were obtained when AAA-measured Phe concentrations were compared with the ECA-, HPLC- or MS/MS-measured values, respectively. A Bland-Altman analysis revealed that mean Phe concentrations determined using AAA were on average 65 μmol/L lower than values measured by our ECA. These results may be the result of minimizing the manipulations performed on the patient sample compared with AAA, HPLC, and MS/MS methods, which involve plasma deproteinization or DBS elution and derivatization. The results reported here confirm that Phe concentrations determined by our ECA method are comparable to those determined by other widely used methods for a broad range of plasma Phe concentrations.

  15. Use of intradermal dilutional testing and skin prick testing: clinical relevance and cost efficiency.

    PubMed

    Seshul, Merritt; Pillsbury, Harold; Eby, Thomas

    2006-09-01

    The objective was to determine the agreement of the positive results from a multiple skin prick test (SPT) device with the ability to determine a definable endpoint through intradermal dilutional testing (IDT) to compare semiquantitatively the degree of positivity of SPT results with quantitative results from IDT and to analyze the cost of immunotherapy based on SPT compared with IDT guided by SPT. Retrospective review of clinical data (random accrual). One hundred thirty-four patients underwent allergy screening using a multiple SPT device. Antigens testing positive by skin prick device were tested using IDT on a separate day. Antigens testing negative by SPT were not evaluated by IDT. Regional allergy testing practice patterns were determined, and a cost analysis using Medicare rates was performed There was good agreement between an antigen testing positive by SPT and the determination of a definable endpoint (93.33%, n = 1,334 antigens). The degree of positivity from the SPT correlated poorly with the final endpoint concentration (r = 0.40, P < .0001). Blended testing techniques were similar in cost when compared with several commonly used allergy testing protocols. Antigens which show reactivity to a multiple SPT device usually have a treatable endpoint that is independent of the degree of positivity of the SPT result. IDT is an important step in the determination of the strongest starting dose of immunotherapy that may be safely administered. Initiating immunotherapy in this manner may potentially create significant health care savings by shortening the time required for a patient to reach their individual maximally tolerated dose. The use of a relatively large screening panel is cost effective and does not increase the average number of antigens treated by immunotherapy. Blended allergy testing techniques that include IDT in their protocol are comparable in cost with commonly used allergy testing protocols.

  16. An optimized computational method for determining the beta dose distribution using a multiple-element thermoluminescent dosimeter system.

    PubMed

    Shen, L; Levine, S H; Catchen, G L

    1987-07-01

    This paper describes an optimization method for determining the beta dose distribution in tissue, and it describes the associated testing and verification. The method uses electron transport theory and optimization techniques to analyze the responses of a three-element thermoluminescent dosimeter (TLD) system. Specifically, the method determines the effective beta energy distribution incident on the dosimeter system, and thus the system performs as a beta spectrometer. Electron transport theory provides the mathematical model for performing the optimization calculation. In this calculation, parameters are determined that produce calculated doses for each of the chip/absorber components in the three-element TLD system. The resulting optimized parameters describe an effective incident beta distribution. This method can be used to determine the beta dose specifically at 7 mg X cm-2 or at any depth of interest. The doses at 7 mg X cm-2 in tissue determined by this method are compared to those experimentally determined using an extrapolation chamber. For a great variety of pure beta sources having different incident beta energy distributions, good agreement is found. The results are also compared to those produced by a commonly used empirical algorithm. Although the optimization method produces somewhat better results, the advantage of the optimization method is that its performance is not sensitive to the specific method of calibration.

  17. Comparing Facial 3D Analysis With DNA Testing to Determine Zygosities of Twins.

    PubMed

    Vuollo, Ville; Sidlauskas, Mantas; Sidlauskas, Antanas; Harila, Virpi; Salomskiene, Loreta; Zhurov, Alexei; Holmström, Lasse; Pirttiniemi, Pertti; Heikkinen, Tuomo

    2015-06-01

    The aim of this study was to compare facial 3D analysis to DNA testing in twin zygosity determinations. Facial 3D images of 106 pairs of young adult Lithuanian twins were taken with a stereophotogrammetric device (3dMD, Atlanta, Georgia) and zygosity was determined according to similarity of facial form. Statistical pattern recognition methodology was used for classification. The results showed that in 75% to 90% of the cases, zygosity determinations were similar to DNA-based results. There were 81 different classification scenarios, including 3 groups, 3 features, 3 different scaling methods, and 3 threshold levels. It appeared that coincidence with 0.5 mm tolerance is the most suitable feature for classification. Also, leaving out scaling improves results in most cases. Scaling was expected to equalize the magnitude of differences and therefore lead to better recognition performance. Still, better classification features and a more effective scaling method or classification in different facial areas could further improve the results. In most of the cases, male pair zygosity recognition was at a higher level compared with females. Erroneously classified twin pairs appear to be obvious outliers in the sample. In particular, faces of young dizygotic (DZ) twins may be so similar that it is very hard to define a feature that would help classify the pair as DZ. Correspondingly, monozygotic (MZ) twins may have faces with quite different shapes. Such anomalous twin pairs are interesting exceptions, but they form a considerable portion in both zygosity groups.

  18. A Comparative Study of Measuring Devices Used During Space Shuttle Processing for Inside Diameters

    NASA Technical Reports Server (NTRS)

    Rodriguez, Antonio

    2006-01-01

    During Space Shuttle processing, discrepancies between vehicle dimensions and per print dimensions determine if a part should be refurbished, replaced or accepted "as-is." The engineer's job is to address each discrepancy by choosing the most accurate procedure and tool available, sometimes with up to ten thousands of an inch tolerance. Four methods of measurement are commonly used at the Kennedy Space Center: 1) caliper, 2) mold impressions, 3) optical comparator, 4) dial bore gage. During a problem report evaluation, uncertainty arose between methods after measuring diameters with variations of up to 0.0004" inches. The results showed that computer based measuring devices are extremely accurate, but when human factor is involved in determining points of reference, the results may vary widely compared to more traditional methods. iv

  19. Statistical evaluation of the metallurgical test data in the ORR-PSF-PVS irradiation experiment. [PWR; BWR

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stallmann, F.W.

    1984-08-01

    A statistical analysis of Charpy test results of the two-year Pressure Vessel Simulation metallurgical irradiation experiment was performed. Determination of transition temperature and upper shelf energy derived from computer fits compare well with eyeball fits. Uncertainties for all results can be obtained with computer fits. The results were compared with predictions in Regulatory Guide 1.99 and other irradiation damage models.

  20. Experimental consideration of the Hansen solubility parameters of as-produced multi-walled carbon nanotubes by inverse gas chromatography.

    PubMed

    Lim, Hyeong Jun; Lee, Kunsil; Cho, Young Shik; Kim, Yern Seung; Kim, Taehoon; Park, Chong Rae

    2014-09-07

    The Hansen solubility parameters (HSPs) of as-produced multi-walled carbon nanotubes (APMWCNTs) were determined by means of the inverse gas chromatography (IGC) technique. Due to non-homogeneous surfaces of the APMWCNTs arising from defects and impurities, it was necessary to establish adequate working conditions for determining the HSPs of the CNTs. We then obtained the HSPs of the APMWCNTs and compared these results with earlier reports as determined by using sedimentation and molecular dynamics simulation methods. It was found that the determination of the HSPs of the CNTs by IGC can give an enhanced determination range based on the adsorption thermodynamic parameters, compared to the HSPs determined using sedimentation methods. And the HSPs of the APMWCNTs, determined here, provided good guidelines for the selection of feasible solvents that can improve the dispersion of the APMWCNTs.

  1. Hydrocarbon group type determination in jet fuels by high performance liquid chromatography

    NASA Technical Reports Server (NTRS)

    Antoine, A. C.

    1977-01-01

    Results are given for the analysis of some jet and diesel fuel samples which were prepared from oil shale and coal syncrudes. Thirty-two samples of varying chemical composition and physical properties were obtained. Hydrocarbon types in these samples were determined by fluorescent indicator adsorption (FIA) analysis, and the results from three laboratories are presented and compared. Recently, rapid high performance liquid chromatography (HPLC) methods have been proposed for hydrocarbon group type analysis, with some suggestion for their use as a replacement of the FIA technique. Two of these methods were used to analyze some of the samples, and these results are also presented and compared. Two samples of petroleum-based Jet A fuel are similarly analyzed.

  2. Field test of available methods to measure remotely SO2 and NOx emissions from ships

    NASA Astrophysics Data System (ADS)

    Balzani Lööv, J. M.; Alfoldy, B.; Beecken, J.; Berg, N.; Berkhout, A. J. C.; Duyzer, J.; Gast, L. F. L.; Hjorth, J.; Jalkanen, J.-P.; Lagler, F.; Mellqvist, J.; Prata, F.; van der Hoff, G. R.; Westrate, H.; Swart, D. P. J.; Borowiak, A.

    2013-11-01

    Methods for the determination of ship fuel sulphur content and NOx emission factors from remote measurements have been compared in the harbour of Rotterdam and compared to direct stack emission measurements on the ferry Stena Hollandica. The methods were selected based on a review of the available literature on ship emission measurements. They were either optical (LIDAR, DOAS, UV camera), combined with model based estimates of fuel consumption, or based on the so called "sniffer" principle, where SO2 or NOx emission factors are determined from simultaneous measurement of the increase of CO2 and SO2 or NOx concentrations in the plume of the ship compared to the background. The measurements were performed from stations at land, from a boat, and from a helicopter. Mobile measurement platforms were found to have important advantages compared to the landbased ones because they allow to optimize the sampling conditions and to sample from ships on the open sea. Although optical methods can provide reliable results, it was found that at the state of the art, the "sniffer" approach is the most convenient technique for determining both SO2 and NOx emission factors remotely. The average random error on the determination of SO2 emission factors comparing two identical instrumental set-ups was 6%. However, it was found that apparently minor differences in the instrumental characteristics, such as response time, could cause significant differences between the emission factors determined. Direct stack measurements showed that about 14% of the fuel sulphur content was not emitted as SO2. This was supported by the remote measurements and is in agreement with the results of other field studies.

  3. Field test of available methods to measure remotely SOx and NOx emissions from ships

    NASA Astrophysics Data System (ADS)

    Balzani Lööv, J. M.; Alfoldy, B.; Gast, L. F. L.; Hjorth, J.; Lagler, F.; Mellqvist, J.; Beecken, J.; Berg, N.; Duyzer, J.; Westrate, H.; Swart, D. P. J.; Berkhout, A. J. C.; Jalkanen, J.-P.; Prata, A. J.; van der Hoff, G. R.; Borowiak, A.

    2014-08-01

    Methods for the determination of ship fuel sulphur content and NOx emission factors based on remote measurements have been compared in the harbour of Rotterdam and compared to direct stack emission measurements on the ferry Stena Hollandica. The methods were selected based on a review of the available literature on ship emission measurements. They were either optical (LIDAR, Differential Optical Absorption Spectroscopy (DOAS), UV camera), combined with model-based estimates of fuel consumption, or based on the so called "sniffer" principle, where SO2 or NOx emission factors are determined from simultaneous measurement of the increase of CO2 and SO2 or NOx concentrations in the plume of the ship compared to the background. The measurements were performed from stations at land, from a boat and from a helicopter. Mobile measurement platforms were found to have important advantages compared to the land-based ones because they allow optimizing the sampling conditions and sampling from ships on the open sea. Although optical methods can provide reliable results it was found that at the state of the art level, the "sniffer" approach is the most convenient technique for determining both SO2 and NOx emission factors remotely. The average random error on the determination of SO2 emission factors comparing two identical instrumental set-ups was 6%. However, it was found that apparently minor differences in the instrumental characteristics, such as response time, could cause significant differences between the emission factors determined. Direct stack measurements showed that about 14% of the fuel sulphur content was not emitted as SO2. This was supported by the remote measurements and is in agreement with the results of other field studies.

  4. Effect of stern hull shape on turning circle of ships

    NASA Astrophysics Data System (ADS)

    Jaswar, Maimun, A.; Wahid, M. A.; Priyanto, A.; Zamani, Pauzi, Saman

    2012-06-01

    Many factors such as: stern hull shape, length, draught, trim, propulsion system and external forces affecting the drift angle influence rate of turn and size of turning circle of ships. This paper discusses turning circle characteristics of U and V stern hull shape of Very Large Crude Oil Carrier (VLCC) ships. The ships have same principal dimension such as length, beam, and draught. The turning circle characteristics of the VLCC ships are simulated at 35 degree of rudder angle. In the analysis, firstly, turning circle performance of U-type VLCC ship is simulated. In the simulation, initial ship speed is determined using given power and rpm. Hydrodynamic derivatives coefficients are determined by including effect of fullness of aft run. Using the obtained, speed and hydrodynamic coefficients, force and moment acting on hull, force and moment induced by propeller, force and moment induced by rudder are determined. Finally, ship trajectory, ratio of speed, yaw angle and drift angle are determined. Results of simulation results of the VLCC ship are compared with the experimental one as validation. Using the same method, V-type VLCC is simulated and the simulation results are compared with U-type VLCC ship. Results shows the turning circle of U-type is larger than V-type due to effect stern hul results of simulation are.

  5. Effectiveness of Quantitative Real Time PCR in Long-Term Follow-up of Chronic Myeloid Leukemia Patients.

    PubMed

    Savasoglu, Kaan; Payzin, Kadriye Bahriye; Ozdemirkiran, Fusun; Berber, Belgin

    2015-08-01

    To determine the use of the Quantitative Real Time PCR (RQ-PCR) assay follow-up with Chronic Myeloid Leukemia (CML) patients. Cross-sectional observational. Izmir Ataturk Education and Research Hospital, Izmir, Turkey, from 2009 to 2013. Cytogenetic, FISH, RQ-PCR test results from 177 CMLpatients' materials selected between 2009 - 2013 years was set up for comparison analysis. Statistical analysis was performed to compare between FISH, karyotype and RQ-PCR results of the patients. Karyotyping and FISH specificity and sensitivity rates determined by ROC analysis compared with RQ-PCR results. Chi-square test was used to compare test failure rates. Sensitivity and specificity values were determined for karyotyping 17.6 - 98% (p=0.118, p > 0.05) and for FISH 22.5 - 96% (p=0.064, p > 0.05) respectively. FISH sensitivity was slightly higher than karyotyping but there was calculated a strong correlation between them (p < 0.001). RQ-PCR test failure rate did not correlate with other two tests (p > 0.05); however, karyotyping and FISH test failure rate was statistically significant (p < 0.001). Besides, the situation needed for karyotype analysis, RQ-PCR assay can be used alone in the follow-up of CMLdisease.

  6. Calculation and benchmarking of an azimuthal pressure vessel neutron fluence distribution using the BOXER code and scraping experiments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Holzgrewe, F.; Hegedues, F.; Paratte, J.M.

    1995-03-01

    The light water reactor BOXER code was used to determine the fast azimuthal neutron fluence distribution at the inner surface of the reactor pressure vessel after the tenth cycle of a pressurized water reactor (PWR). Using a cross-section library in 45 groups, fixed-source calculations in transport theory and x-y geometry were carried out to determine the fast azimuthal neutron flux distribution at the inner surface of the pressure vessel for four different cycles. From these results, the fast azimuthal neutron fluence after the tenth cycle was estimated and compared with the results obtained from scraping test experiments. In these experiments,more » small samples of material were taken from the inner surface of the pressure vessel. The fast neutron fluence was then determined form the measured activity of the samples. Comparing the BOXER and scraping test results have maximal differences of 15%, which is very good, considering the factor of 10{sup 3} neutron attenuation between the reactor core and the pressure vessel. To compare the BOXER results with an independent code, the 21st cycle of the PWR was also calculated with the TWODANT two-dimensional transport code, using the same group structure and cross-section library. Deviations in the fast azimuthal flux distribution were found to be <3%, which verifies the accuracy of the BOXER results.« less

  7. CHAPTER 10: CURRENT TECHNICAL PROBLEMS IN EMERGY ANALYSIS

    EPA Science Inventory

    Technical problems related to the determination of the emergy base for self-organization in environmental systems are considered in this paper. The comparability of emergy analysis results depends on emergy analysts making similar choices in determining the emergy base for a part...

  8. COMPARATIVE STUDY OF SPRAY BOOTH FILTER SYSTEM EFFICIENCY

    EPA Science Inventory

    The paper summarizes results of research conducted to determine the capability of various dry paint overspray arrestor systems to capture particles as small as about 1 micrometer in surface diameter. The testing used on optical particle counter to determine the concentration of p...

  9. Comparison of segmentation algorithms for fluorescence microscopy images of cells.

    PubMed

    Dima, Alden A; Elliott, John T; Filliben, James J; Halter, Michael; Peskin, Adele; Bernal, Javier; Kociolek, Marcin; Brady, Mary C; Tang, Hai C; Plant, Anne L

    2011-07-01

    The analysis of fluorescence microscopy of cells often requires the determination of cell edges. This is typically done using segmentation techniques that separate the cell objects in an image from the surrounding background. This study compares segmentation results from nine different segmentation techniques applied to two different cell lines and five different sets of imaging conditions. Significant variability in the results of segmentation was observed that was due solely to differences in imaging conditions or applications of different algorithms. We quantified and compared the results with a novel bivariate similarity index metric that evaluates the degree of underestimating or overestimating a cell object. The results show that commonly used threshold-based segmentation techniques are less accurate than k-means clustering with multiple clusters. Segmentation accuracy varies with imaging conditions that determine the sharpness of cell edges and with geometric features of a cell. Based on this observation, we propose a method that quantifies cell edge character to provide an estimate of how accurately an algorithm will perform. The results of this study will assist the development of criteria for evaluating interlaboratory comparability. Published 2011 Wiley-Liss, Inc.

  10. Smartphone Assessment of Knee Flexion Compared to Radiographic Standards

    PubMed Central

    Dietz, Matthew J.; Sprando, Daniel; Hanselman, Andrew E.; Regier, Michael D.; Frye, Benjamin M.

    2017-01-01

    Purpose Measuring knee range of motion (ROM) is an important assessment for the outcomes of total knee arthroplasty. Recent technological advances have led to the development and use of accelerometer-based smartphone applications to measure knee ROM. The purpose of this study was to develop, standardize, and validate methods of utilizing smartphone accelerometer technology compared to radiographic standards, visual estimation, and goniometric evaluation. Methods Participants used visual estimation, a long-arm goniometer, and a smartphone accelerometer to determine range of motion of a cadaveric lower extremity; these results were compared to radiographs taken at the same angles. Results The optimal smartphone position was determined to be on top of the leg at the distal femur and proximal tibia location. Between methods, it was found that the smartphone and goniometer were comparably reliable in measuring knee flexion (ICC = 0.94; 95% CI: 0.91–0.96). Visual estimation was found to be the least reliable method of measurement. Conclusions The results suggested that the smartphone accelerometer was non-inferior when compared to the other measurement techniques, demonstrated similar deviations from radiographic standards, and did not appear to be influenced by the person performing the measurements or the girth of the extremity. PMID:28179062

  11. Efficient flow injection and sequential injection methods for spectrophotometric determination of oxybenzone in sunscreens based on reaction with Ni(II).

    PubMed

    Chisvert, A; Salvador, A; Pascual-Martí, M C; March, J G

    2001-04-01

    Spectrophotometric determination of a widely used UV-filter, such as oxybenzone, is proposed. The method is based on the complexation reaction between oxybenzone and Ni(II) in ammoniacal medium. The stoichiometry of the reaction, established by the Job method, was 1:1. Reaction conditions were studied and the experimental parameters were optimized, for both flow injection (FI) and sequential injection (SI) determinations, with comparative purposes. Sunscreen formulations containing oxybenzone were analyzed by the proposed methods and results compared with those obtained by HPLC. Data show that both FI and SI procedures provide accurate and precise results. The ruggedness, sensitivity and LOD are adequate to the analysis requirements. The sample frequency obtained by FI is three-fold higher than that of SI analysis. SI is less reagent-consuming than FI.

  12. Comparison of intradermal dilutional testing, skin prick testing, and modified quantitative testing for common allergens.

    PubMed

    Peltier, Jacques; Ryan, Matthew W

    2007-08-01

    To compare and correlate wheal size using the Multi-Test II applicator with the endpoint obtained by intradermal dilutional testing (IDT) for 5 common allergens. To examine the safety of modified quantitative testing (MQT) for determining immunotherapy starting doses. Prospective comparative clinical study. A total of 134 subjects were simultaneously skin tested for immediate hypersensitivity using the Multi-Test II device and IDT. There was a 77% concordance between results from IDT and results from MQT. When there was a difference, MQT predicted a safer endpoint for starting immunotherapy in all but 2 cases. Wheal size by SPT is predictive of endpoint by IDT. MQT is nearly as effective as formal IDT in determining endpoint. Modified quantitative testing appears to be a safe alternative to IDT for determining starting doses for immunotherapy.

  13. Learning French as a Second Official Language in Canada: Comparing Monolingual and Bilingual Students at Grade 6

    ERIC Educational Resources Information Center

    Mady, Callie

    2014-01-01

    This paper presents the results of a study that compared the French as a second official achievement of three groups of students: (1) Canadian-born English speaking (CBE), (2) Canadian-born multilingual (CBM), and (3) immigrant multilinguals (IMM) as determined by multiskills test results. ANOVAs and subsequent post hoc tests revealed that the…

  14. Lateral and longitudinal aerodynamic stability and control parameters of the basic vortex flap research aircraft as determined from flight test data

    NASA Technical Reports Server (NTRS)

    Suit, W. T.; Batterson, J. G.

    1986-01-01

    The aerodynamics of the basic F-106B were determined at selected points in the flight envelope. The test aircraft and flight procedures were presented. Aircraft instrumentation and the data system were discussed. The parameter extraction procedure was presented along with a discussion of the test flight results. The results were used to predict the aircraft motions for maneuvers that were not used to determine the vehicle aerodynamics. The control inputs used to maneuver the aircraft to get data for the determination of the aerodynamic parameters were discussed in the flight test procedures. The results from the current flight tests were compared with the results from wind tunnel test of the basic F-106B.

  15. Gaps in affiliation indexing in Scopus and PubMed

    PubMed Central

    Schmidt, Cynthia M.; Cox, Roxanne; Fial, Alissa V.; Hartman, Teresa L.; Magee, Martha L.

    2016-01-01

    Objective The authors sought to determine whether unexpected gaps existed in Scopus's author affiliation indexing of publications written by the University of Nebraska Medical Center or Nebraska Medicine (UNMC/NM) authors during 2014. Methods First, we compared Scopus affiliation identifier search results to PubMed affiliation keyword search results. Then, we searched Scopus using affiliation keywords (UNMC, etc.) and compared the results to PubMed affiliation keyword and Scopus affiliation identifier searches. Results We found that Scopus's records for approximately 7% of UNMC/NM authors' publications lacked appropriate UNMC/NM author affiliation identifiers, and many journals' publishers were supplying incomplete author affiliation information to PubMed. Conclusions Institutions relying on Scopus to track their impact should determine whether Scopus's affiliation identifiers will, in fact, identify all articles published by their authors and investigators. PMID:27076801

  16. Determining the solar-flare photospheric scale height from SMM gamma-ray measurements

    NASA Technical Reports Server (NTRS)

    Lingenfelter, Richard E.

    1991-01-01

    A connected series of Monte Carlo programs was developed to make systematic calculations of the energy, temporal and angular dependences of the gamma-ray line and neutron emission resulting from such accelerated ion interactions. Comparing the results of these calculations with the Solar Maximum Mission/Gamma Ray Spectrometer (SMM/GRS) measurements of gamma-ray line and neutron fluxes, the total number and energy spectrum of the flare-accelerated ions trapped on magnetic loops at the Sun were determined and the angular distribution, pitch angle scattering, and mirroring of the ions on loop fields were constrained. Comparing the calculations with measurements of the time dependence of the neutron capture line emission, a determination of the He-3/H ratio in the photosphere was also made. The diagnostic capabilities of the SMM/GRS measurements were extended by developing a new technique to directly determine the effective photospheric scale height in solar flares from the neutron capture gamma-ray line measurements, and critically test current atmospheric models in the flare region.

  17. Quantitative CT based radiomics as predictor of resectability of pancreatic adenocarcinoma

    NASA Astrophysics Data System (ADS)

    van der Putten, Joost; Zinger, Svitlana; van der Sommen, Fons; de With, Peter H. N.; Prokop, Mathias; Hermans, John

    2018-02-01

    In current clinical practice, the resectability of pancreatic ductal adenocarcinoma (PDA) is determined subjec- tively by a physician, which is an error-prone procedure. In this paper, we present a method for automated determination of resectability of PDA from a routine abdominal CT, to reduce such decision errors. The tumor features are extracted from a group of patients with both hypo- and iso-attenuating tumors, of which 29 were resectable and 21 were not. The tumor contours are supplied by a medical expert. We present an approach that uses intensity, shape, and texture features to determine tumor resectability. The best classification results are obtained with fine Gaussian SVM and the L0 Feature Selection algorithms. Compared to expert predictions made on the same dataset, our method achieves better classification results. We obtain significantly better results on correctly predicting non-resectability (+17%) compared to a expert, which is essential for patient treatment (negative prediction value). Moreover, our predictions of resectability exceed expert predictions by approximately 3% (positive prediction value).

  18. Electrochemical corrosion studies

    NASA Technical Reports Server (NTRS)

    Knockemus, W. W.

    1986-01-01

    The objective was to gain familiarity with the Model 350 Corrosion Measurement Console, to determine if metal protection by grease coatings can be measured by the polarization-resistance method, and to compare corrosion rates of 4130 steel coated with various greases. Results show that grease protection of steel may be determined electrochemically. Studies were also conducted to determine the effectiveness of certain corrosion inhibitors on aluminum and steel.

  19. Raman spectroscopy in transition metals and alloys at ultrahigh pressures.

    NASA Astrophysics Data System (ADS)

    Goncharov, Alexander; Gregoryanz, Eugene; Struzhkin, Viktor; Hemley, Russell; Mao, Ho-Kwang; Merkel, Sebastien; Huang, Eugene

    2001-03-01

    We present the results of Raman measurements of hexagonal close-packed phases of Fe, Fe_(1-x)Nix (x=0.01-0.2), Re up to megabar pressures (>100 GPa). We compare frequencies and their pressure dependences of the Raman-active E_2g mode for different compositions. We find a substantial decrease in the phonon frequency for Fe:Ne alloy compared to pure Fe, which is tentatively attributed to magneto-elastic coupling. We also determine the mode Grüneisen parameters and compare them to other experimental results and theoretical calculations. The data for pure Fe and Re are used to determine the pressure dependence of the C_44 shear elastic modulus [1,2]. [1] A. P. Jephcoat, H. Olijnyk, K. Refson, Eos 80, F929 (1999). [2] S. Merkel et al., Science 288, 1626 (2000).

  20. Comparison between Two Linear Supervised Learning Machines' Methods with Principle Component Based Methods for the Spectrofluorimetric Determination of Agomelatine and Its Degradants.

    PubMed

    Elkhoudary, Mahmoud M; Naguib, Ibrahim A; Abdel Salam, Randa A; Hadad, Ghada M

    2017-05-01

    Four accurate, sensitive and reliable stability indicating chemometric methods were developed for the quantitative determination of Agomelatine (AGM) whether in pure form or in pharmaceutical formulations. Two supervised learning machines' methods; linear artificial neural networks (PC-linANN) preceded by principle component analysis and linear support vector regression (linSVR), were compared with two principle component based methods; principle component regression (PCR) as well as partial least squares (PLS) for the spectrofluorimetric determination of AGM and its degradants. The results showed the benefits behind using linear learning machines' methods and the inherent merits of their algorithms in handling overlapped noisy spectral data especially during the challenging determination of AGM alkaline and acidic degradants (DG1 and DG2). Relative mean squared error of prediction (RMSEP) for the proposed models in the determination of AGM were 1.68, 1.72, 0.68 and 0.22 for PCR, PLS, SVR and PC-linANN; respectively. The results showed the superiority of supervised learning machines' methods over principle component based methods. Besides, the results suggested that linANN is the method of choice for determination of components in low amounts with similar overlapped spectra and narrow linearity range. Comparison between the proposed chemometric models and a reported HPLC method revealed the comparable performance and quantification power of the proposed models.

  1. The usefulness of biotyping in the determination of selected pathogenicity determinants in Streptococcus mutans

    PubMed Central

    2014-01-01

    Background Streptococcus mutans is known to be a primary etiological factor of dental caries, a widespread and growing disease in Polish children. Recognition of novel features determining the pathogenicity of this pathogen may contribute to understanding the mechanisms of bacterial infections. The goal of the study was to determine the activity of prephenate dehydrogenase (PHD) and to illuminate the role of the enzyme in S. mutans pathogenicity. The strains were biotyped based on STREPTOtest 24 biochemical identification tests and the usefulness of biotyping in the determination of S. mutans pathogenicity determinants was examined. Results Out of ninety strains isolated from children with deciduous teeth fifty three were classified as S. mutans species. PDH activity was higher (21.69 U/mg on average) in the experimental group compared to the control group (5.74 U/mg on average) (P <0.001). Moreover, it was demonstrated that biotype I, established basing on the biochemical characterization of the strain, was predominant (58.5%) in oral cavity streptococcosis. Its dominance was determined by higher PDH activity compared to biotypes II and III (P = 0.0019). Conclusions The usefulness of biotyping in the determination of Streptococcus mutans pathogenicity determinants was demonstrated. The obtained results allow for better differentiation of S. mutans species and thus may contribute to recognition of pathogenic bacteria transmission mechanisms and facilitate treatment. PMID:25096795

  2. Tissue type determination by impedance measurement: A bipolar and monopolar comparison

    PubMed Central

    Sharp, Jack; Bouazza-Marouf, Kaddour; Noronha, Dorita; Gaur, Atul

    2017-01-01

    Background: In certain medical applications, it is necessary to be able to determine the position of a needle inside the body, specifically with regards to identifying certain tissue types. By measuring the electrical impedance of specific tissue types, it is possible to determine the type of tissue the tip of the needle (or probe) is at. Materials and Methods: Two methods have been investigated for electric impedance detection; bipolar and monopolar. Commercially available needle electrodes are of a monopolar type. Although many patents exist on the bipolar setups, these have not as yet been commercialized. This paper reports a comparison of monopolar and bipolar setups for tissue type determination. In vitro experiments were carried out on pork to compare this investigation with other investigations in this field. Results: The results show that both monopolar and bipolar setups are capable of determining tissue type. However, the bipolar setup showed slightly better results; the difference between the different soft tissue type impedances was greater compared to the monopolar method. Conclusion: Both monopolar and bipolar electrical impedance setups work very similarly in inhomogeneous volumes such as biological tissue. There is a clear potential for clinical applications with impedance-based needle guidance, with both the monopolar and bipolar setups. It is, however, worth noting that the bipolar setup is more versatile. PMID:28217047

  3. Summary of longitudinal stability and control parameters as determined from space shuttle Columbia flight test data

    NASA Technical Reports Server (NTRS)

    Suit, W. T.

    1986-01-01

    Extensive wind tunnel tests were conducted to establish the preflight aerodynamics of the Shuttle vehicle. This paper presents the longitudinal, short-period aerodynamics of the space shuttle Columbia as determined from flight test data. These flight-determined results are compared with the preflight predictions, and areas of agreement or disagreement are noted. In addition to the short-period aerodynamics, the pitch RCS effectiveness was determined.

  4. Comparing measurement response and inverted results of electrical resistivity tomography instruments

    USGS Publications Warehouse

    Parsekian, Andrew D.; Claes, Niels; Singha, Kamini; Minsley, Burke J.; Carr, Bradley; Voytek, Emily; Harmon, Ryan; Kass, Andy; Carey, Austin; Thayer, Drew; Flinchum, Brady

    2017-01-01

    In this investigation, we compare the results of electrical resistivity measurements made by six commercially available instruments on the same line of electrodes to determine if there are differences in the measured data or inverted results. These comparisons are important to determine whether measurements made between different instruments are consistent. We also degraded contact resistance on one quarter of the electrodes to study how each instrument responds to different electrical connection with the ground. We find that each instrument produced statistically similar apparent resistivity results, and that any conservative assessment of the final inverted resistivity models would result in a similar interpretation for each. We also note that inversions, as expected, are affected by measurement error weights. Increased measurement errors were most closely associated with degraded contact resistance in this set of experiments. In a separate test we recorded the full measured waveform for a single four-electrode array to show how poor electrode contact and instrument-specific recording settings can lead to systematic measurement errors. We find that it would be acceptable to use more than one instrument during an investigation with the expectation that the results would be comparable assuming contact resistance remained consistent.

  5. Total atmospheric ozone determined from spectral measurements of direct solar UV irradiance

    NASA Astrophysics Data System (ADS)

    Huber, Martin; Blumthaler, Mario; Ambach, Walter; Staehelin, Johannes

    1995-01-01

    With a double monochromator, high resolution spectral measurements of direct solar UV-irradiance were performed in Arosa during February and March, 1993. Total atmospheric ozone amount is determined by fitting model calculations to the measured spectra. The results are compared with the operationally performed measurements of a Dobson and a Brewer spectrometer. The total ozone amount determined from spectral measurements differs from the results of the Dobson instrument by -1.1±0.9% and from those of the Brewer instrument by -0.4±0.7%.

  6. Gaps in affiliation indexing in Scopus and PubMed.

    PubMed

    Schmidt, Cynthia M; Cox, Roxanne; Fial, Alissa V; Hartman, Teresa L; Magee, Martha L

    2016-04-01

    The authors sought to determine whether unexpected gaps existed in Scopus's author affiliation indexing of publications written by the University of Nebraska Medical Center or Nebraska Medicine (UNMC/NM) authors during 2014. First, we compared Scopus affiliation identifier search results to PubMed affiliation keyword search results. Then, we searched Scopus using affiliation keywords (UNMC, etc.) and compared the results to PubMed affiliation keyword and Scopus affiliation identifier searches. We found that Scopus's records for approximately 7% of UNMC/NM authors' publications lacked appropriate UNMC/NM author affiliation identifiers, and many journals' publishers were supplying incomplete author affiliation information to PubMed. Institutions relying on Scopus to track their impact should determine whether Scopus's affiliation identifiers will, in fact, identify all articles published by their authors and investigators.

  7. Gain determination of optical active doped planar waveguides

    NASA Astrophysics Data System (ADS)

    Šmejcký, J.; Jeřábek, V.; Nekvindová, P.

    2017-12-01

    This paper summarizes the results of the gain transmission characteristics measurement carried out on the new ion exchange Ag+ - Na+ optical Er3+ and Yb3+ doped active planar waveguides realized on a silica based glass substrates. The results were used for optimization of the precursor concentration in the glass substrates. The gain measurements were performed by the time domain method using a pulse generator, as well as broadband measurement method using supercontinuum optical source in the wavelength domain. Both methods were compared and the results were graphically processed. It has been confirmed that pulse method is useful as it provides a very accurate measurement of the gain - pumping power characteristics for one wavelength. In the case of radiation spectral characteristics, our measurement exactly determined the maximum gain wavelength bandwidth of the active waveguide. The spectral characteristics of the pumped and unpumped waveguides were compared. The gain parameters of the reported silica-based glasses can be compared with the phosphate-based parameters, typically used for optical active devices application.

  8. Comparison of simulated and actual wind shear radar data products

    NASA Technical Reports Server (NTRS)

    Britt, Charles L.; Crittenden, Lucille H.

    1992-01-01

    Prior to the development of the NASA experimental wind shear radar system, extensive computer simulations were conducted to determine the performance of the radar in combined weather and ground clutter environments. The simulation of the radar used analytical microburst models to determine weather returns and synthetic aperture radar (SAR) maps to determine ground clutter returns. These simulations were used to guide the development of hazard detection algorithms and to predict their performance. The structure of the radar simulation is reviewed. Actual flight data results from the Orlando and Denver tests are compared with simulated results. Areas of agreement and disagreement of actual and simulated results are shown.

  9. Evaluation of Aution Max AX-4030 and 9UB Uriflet, 10PA Aution Sticks urine dipsticks in the automated urine test strip analysis.

    PubMed

    Rota, Cristina; Biondi, Marco; Trenti, Tommaso

    2011-09-26

    Aution Max AX-4030, a test strip analyzer recently introduced to the market, represents an upgrade of the Aution Max AX-4280 widely employed for urinalysis. This new instrument model can allocate two different test strips at the same time. In the present study the two instruments have been compared together with the usage of Uriflet 9UB and the recently produced Aution Sticks 10PA urine strips, the latter presenting an additional test area for the measurement of urinary creatinine. Imprecision and correlation between instruments and strips have been evaluated for chemical-physical parameters. Accuracy was evaluated for protein, glucose and creatinine by comparing the semi-quantitative results to those obtained by quantitative methods. The well-known interference effect of high ascorbic acid levels on urine glucose test strip determination was evaluated, ascorbic acid influence was also evaluated on protein and creatinine determination. The two instruments have demonstrated comparable performances: precision and correlation between instruments and strips, evaluated for chemical-physical parameters, were always good. Furthermore, accuracy was always very good: results of protein and glucose semi-quantitative measurements resulted to be highly correlated with those obtained by quantitative methods. Moreover, the semi-quantitative measurements of creatinine, employing Aution Sticks 10PA urine strips, were highly comparable with quantitative results. 10PA urine strips are eligible for urine creatinine determination with the possibility of correcting urinalysis results for urinary creatinine concentration, whenever necessary and calculating the protein creatinine ratio. Further studies should be carried out to evaluate effectiveness and appropriateness of the usage of creatinine semi-quantitative analysis.

  10. Fatigue crack growth with single overload - Measurement and modeling

    NASA Technical Reports Server (NTRS)

    Davidson, D. L.; Hudak, S. J., Jr.; Dexter, R. J.

    1987-01-01

    This paper compares experiments with an analytical model of fatigue crack growth under variable amplitude. The stereoimaging technique was used to measure displacements near the tips of fatigue cracks undergoing simple variations in load amplitude-single overloads and overload/underload combinations. Measured displacements were used to compute strains, and stresses were determined from the strains. Local values of crack driving force (Delta-K effective) were determined using both locally measured opening loads and crack tip opening displacements. Experimental results were compared with simulations made for the same load variation conditions using Newman's FAST-2 model. Residual stresses caused by overloads, crack opening loads, and growth retardation periods were compared.

  11. Hemispheric Preference and Cyclic Variation of Solar Filament Chirality

    NASA Astrophysics Data System (ADS)

    Hazra, Soumitra; Mahajan, Sushant S.; Douglas, William; Martens, Petrus C.

    2017-08-01

    Although the hemispheric preference of magnetic topological features in the solar atmosphere is a well-established fact, strength and cyclic variation of the hemispheric rule is a debatable issue. In this work, we study the chirality of 3480 solar filaments from 2000 to 2016. We determine the chirality of filaments manually and compare with the results obtained from the Advanced Automated Filament Detection and Characterization Code (AAFDCC). We find that 83% of our manually determined filaments follow the hemispheric chirality rule, while 58% of automatically determined filamentsfollow the same. We also compare our result with an other manually compiled list by Pevtsov et al. (2003). We find that our list matches Pevtsovs manually compiled list with 90% accuracy. We also find that the hemispheric chirality rule does not vary from cycle to cycle. However, the strength of the hemispheric preference decreases at the end and beginning phase of the solar cycle.

  12. Experimental investigation on consistency limits of cement and lime-stabilized marine sediments.

    PubMed

    Wang, DongXing; Zentar, Rachid; Abriak, Nor Edine; Xu, WeiYa

    2012-06-01

    This paper presents the effects of treatments with cement and lime on the consistency limits of marine sediments dredged from Dunkirk port. The Casagrande percussion test and the fall cone test were used to determine the liquid limits of raw sediments and treated marine sediments. For the evaluation of the plastic limits, the results of the fall cone test were compared with those obtained by the rolling test method. The relationship between the water contents and the penetration depths for the determination of the liquid limit and the plastic limit was explored. Liquid limits at 15.5 mm and plastic limits at 1.55 mm seem to be a more appropriate choice for the studied marine sediments compared with the limits determined by other used prediction methods. Finally, the effect of cement treatment and lime treatment on the Casagrande classification of the studied sediments was investigated according to the different prediction results.

  13. Comparison study of two procedures for the determination of emamectin benzoate in medicated fish feed.

    PubMed

    Farer, Leslie J; Hayes, John M

    2005-01-01

    A new method has been developed for the determination of emamectin benzoate in fish feed. The method uses a wet extraction, cleanup by solid-phase extraction, and quantitation and separation by liquid chromatography (LC). In this paper, we compare the performance of this method with that of a previously reported LC assay for the determination of emamectin benzoate in fish feed. Although similar to the previous method, the new procedure uses a different sample pretreatment, wet extraction, and quantitation method. The performance of the new method was compared with that of the previously reported method by analyses of 22 medicated feed samples from various commercial sources. A comparison of the results presented here reveals slightly lower assay values obtained with the new method. Although a paired sample t-test indicates the difference in results is significant, this difference is within the method precision of either procedure.

  14. Characterization of primary standards for use in the HPLC analysis of the procyanidin content of cocoa and chocolate containing products.

    PubMed

    Hurst, William J; Stanley, Bruce; Glinski, Jan A; Davey, Matthew; Payne, Mark J; Stuart, David A

    2009-10-15

    This report describes the characterization of a series of commercially available procyanidin standards ranging from dimers DP = 2 to decamers DP = 10 for the determination of procyanidins from cocoa and chocolate. Using a combination of HPLC with fluorescence detection and MALDI-TOF mass spectrometry, the purity of each standard was determined and these data were used to determine relative response factors. These response factors were compared with other response factors obtained from published methods. Data comparing the procyanidin analysis of a commercially available US dark chocolate calculated using each of the calibration methods indicates divergent results and demonstrate that previous methods may significantly underreport the procyanidins in cocoa-containing products. These results have far reaching implications because the previous calibration methods have been used to develop data for a variety of scientific reports, including food databases and clinical studies.

  15. Determination of germanium by AAS in chloride-containing matrices.

    PubMed

    Anwari, M A; Abbasi, H U; Volkan, M; Ataman, O Y

    1996-06-01

    Interference effects of NaCl on the ET-AAS determination of Ge have been studied. The use of several matrix modifiers to alleviate this problem such as Ni and Zn perchlorates and nitrates, nitric acid, ammonium nitrate are reported. The stabilizing effect of Zn and Ni perchlorates allows the use of high pretreatment temperatures. NaCl is thus thermally volatilized from the atomizer by employing pretreatment temperatures higher than 1500 degrees C resulting in an improved sensitivity. Germanium levels in zinc plant slag samples, have been determined and compared to those obtained for the same samples spiked with NaCl with platform and wall atomization using nickel perchlorate as a matrix modifier. The results were compared with those from a hydride generation system equipped with a liquid nitrogen trap. The recoveries for germanium have been almost complete and amount to 99% for the original slag samples and 80% for 15% (w/w) NaCl containing spiked samples.

  16. The predictive value of the sacral base pressure test in detecting specific types of sacroiliac dysfunction

    PubMed Central

    Mitchell, Travis D.; Urli, Kristina E.; Breitenbach, Jacques; Yelverton, Chris

    2007-01-01

    Abstract Objective This study aimed to evaluate the validity of the sacral base pressure test in diagnosing sacroiliac joint dysfunction. It also determined the predictive powers of the test in determining which type of sacroiliac joint dysfunction was present. Methods This was a double-blind experimental study with 62 participants. The results from the sacral base pressure test were compared against a cluster of previously validated tests of sacroiliac joint dysfunction to determine its validity and predictive powers. The external rotation of the feet, occurring during the sacral base pressure test, was measured using a digital inclinometer. Results There was no statistically significant difference in the results of the sacral base pressure test between the types of sacroiliac joint dysfunction. In terms of the results of validity, the sacral base pressure test was useful in identifying positive values of sacroiliac joint dysfunction. It was fairly helpful in correctly diagnosing patients with negative test results; however, it had only a “slight” agreement with the diagnosis for κ interpretation. Conclusions In this study, the sacral base pressure test was not a valid test for determining the presence of sacroiliac joint dysfunction or the type of dysfunction present. Further research comparing the agreement of the sacral base pressure test or other sacroiliac joint dysfunction tests with a criterion standard of diagnosis is necessary. PMID:19674694

  17. Flame thermometry

    NASA Astrophysics Data System (ADS)

    Strojnik, Marija; Páez, Gonzalo; Granados, Juan C.

    2006-08-01

    We determine the temperature distribution within the flame as a function of position. We determined temperature distribution and the length of a flame by dual-wavelength thermometry, at 470 nm and 515 nm. The error percentages on the temperature and the flame length measurements are 1.9% as compared with the predicted thermodynamic results.

  18. 42 CFR 493.573 - Continuing Federal oversight of private nonprofit accreditation organizations and approved State...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... sooner if CMS determines an earlier review is required. (b) Validation review. Following the end of a validation review period, CMS evaluates the validation inspection results for each approved accreditation... determined through a comparability or validation review, must furnish CMS, upon request, with the...

  19. 42 CFR 493.573 - Continuing Federal oversight of private nonprofit accreditation organizations and approved State...

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... sooner if CMS determines an earlier review is required. (b) Validation review. Following the end of a validation review period, CMS evaluates the validation inspection results for each approved accreditation... determined through a comparability or validation review, must furnish CMS, upon request, with the...

  20. 42 CFR 493.573 - Continuing Federal oversight of private nonprofit accreditation organizations and approved State...

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... sooner if CMS determines an earlier review is required. (b) Validation review. Following the end of a validation review period, CMS evaluates the validation inspection results for each approved accreditation... determined through a comparability or validation review, must furnish CMS, upon request, with the...

  1. 42 CFR 493.573 - Continuing Federal oversight of private nonprofit accreditation organizations and approved State...

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... sooner if CMS determines an earlier review is required. (b) Validation review. Following the end of a validation review period, CMS evaluates the validation inspection results for each approved accreditation... determined through a comparability or validation review, must furnish CMS, upon request, with the...

  2. 42 CFR 493.573 - Continuing Federal oversight of private nonprofit accreditation organizations and approved State...

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... sooner if CMS determines an earlier review is required. (b) Validation review. Following the end of a validation review period, CMS evaluates the validation inspection results for each approved accreditation... determined through a comparability or validation review, must furnish CMS, upon request, with the...

  3. Whole exome sequencing for determination of tumor mutation load in liquid biopsy from advanced cancer patients.

    PubMed

    Koeppel, Florence; Blanchard, Steven; Jovelet, Cécile; Genin, Bérengère; Marcaillou, Charles; Martin, Emmanuel; Rouleau, Etienne; Solary, Eric; Soria, Jean-Charles; André, Fabrice; Lacroix, Ludovic

    2017-01-01

    Tumor mutation load (TML) has been proposed as a biomarker of patient response to immunotherapy in several studies. TML is usually determined by tumor biopsy DNA (tDNA) whole exome sequencing (WES), therefore TML evaluation is limited by informative biopsy availability. Circulating cell free DNA (cfDNA) provided by liquid biopsy is a surrogate specimen to biopsy for molecular profiling. Nevertheless performing WES on DNA from plasma is technically challenging and the ability to determine tumor mutation load from liquid biopsies remains to be demonstrated. In the current study, WES was performed on cfDNA from 32 metastatic patients of various cancer types included into MOSCATO 01 (NCT01566019) and/or MATCHR (NCT02517892) molecular triage trials. Results from targeted gene sequencing (TGS) and WES performed on cfDNA were compared to results from tumor tissue biopsy. In cfDNA samples, WES mutation detection sensitivity was 92% compared to targeted sequencing (TGS). When comparing cfDNA-WES to tDNA-WES, mutation detection sensitivity was 53%, consistent with previously published prospective study comparing cfDNA-TGS to tDNA-TGS. For samples in which presence of tumor DNA was confirmed in cfDNA, tumor mutation load from liquid biopsy was correlated with tumor biopsy. Taken together, this study demonstrated that liquid biopsy may be applied to determine tumor mutation load. Qualification of liquid biopsy for interpretation is a crucial point to use cfDNA for mutational load estimation.

  4. Whole exome sequencing for determination of tumor mutation load in liquid biopsy from advanced cancer patients

    PubMed Central

    Blanchard, Steven; Jovelet, Cécile; Genin, Bérengère; Marcaillou, Charles; Martin, Emmanuel; Rouleau, Etienne; Solary, Eric; Soria, Jean-Charles; André, Fabrice; Lacroix, Ludovic

    2017-01-01

    Tumor mutation load (TML) has been proposed as a biomarker of patient response to immunotherapy in several studies. TML is usually determined by tumor biopsy DNA (tDNA) whole exome sequencing (WES), therefore TML evaluation is limited by informative biopsy availability. Circulating cell free DNA (cfDNA) provided by liquid biopsy is a surrogate specimen to biopsy for molecular profiling. Nevertheless performing WES on DNA from plasma is technically challenging and the ability to determine tumor mutation load from liquid biopsies remains to be demonstrated. In the current study, WES was performed on cfDNA from 32 metastatic patients of various cancer types included into MOSCATO 01 (NCT01566019) and/or MATCHR (NCT02517892) molecular triage trials. Results from targeted gene sequencing (TGS) and WES performed on cfDNA were compared to results from tumor tissue biopsy. In cfDNA samples, WES mutation detection sensitivity was 92% compared to targeted sequencing (TGS). When comparing cfDNA-WES to tDNA-WES, mutation detection sensitivity was 53%, consistent with previously published prospective study comparing cfDNA-TGS to tDNA-TGS. For samples in which presence of tumor DNA was confirmed in cfDNA, tumor mutation load from liquid biopsy was correlated with tumor biopsy. Taken together, this study demonstrated that liquid biopsy may be applied to determine tumor mutation load. Qualification of liquid biopsy for interpretation is a crucial point to use cfDNA for mutational load estimation. PMID:29161279

  5. Novel two wavelength spectrophotometric methods for simultaneous determination of binary mixtures with severely overlapping spectra

    NASA Astrophysics Data System (ADS)

    Lotfy, Hayam M.; Saleh, Sarah S.; Hassan, Nagiba Y.; Salem, Hesham

    2015-02-01

    This work presents the application of different spectrophotometric techniques based on two wavelengths for the determination of severely overlapped spectral components in a binary mixture without prior separation. Four novel spectrophotometric methods were developed namely: induced dual wavelength method (IDW), dual wavelength resolution technique (DWRT), advanced amplitude modulation method (AAM) and induced amplitude modulation method (IAM). The results of the novel methods were compared to that of three well-established methods which were: dual wavelength method (DW), Vierordt's method (VD) and bivariate method (BV). The developed methods were applied for the analysis of the binary mixture of hydrocortisone acetate (HCA) and fusidic acid (FSA) formulated as topical cream accompanied by the determination of methyl paraben and propyl paraben present as preservatives. The specificity of the novel methods was investigated by analyzing laboratory prepared mixtures and the combined dosage form. The methods were validated as per ICH guidelines where accuracy, repeatability, inter-day precision and robustness were found to be within the acceptable limits. The results obtained from the proposed methods were statistically compared with official ones where no significant difference was observed. No difference was observed between the obtained results when compared to the reported HPLC method, which proved that the developed methods could be alternative to HPLC techniques in quality control laboratories.

  6. Measurement of rivaroxaban and apixaban in serum samples of patients

    PubMed Central

    Harenberg, Job; Krämer, Sandra; Du, Shanshan; Zolfaghari, Shabnam; Schulze, Astrid; Krämer, Roland; Weiss, Christel; Wehling, Martin; Lip, Gregory Y H

    2014-01-01

    Background The determination of rivaroxaban and apixaban from serum samples of patients may be beneficial in specific clinical situations when additional blood sampling for plasma and thus the determination of factor Xa activity is not feasible or results are not plausible. Materials and methods The primary aim of this study was to compare the concentrations of rivaroxaban and apixaban in serum with those measured in plasma. Secondary aims were the performance of three different chromogenic methods and concentrations in patients on treatment with rivaroxaban 10 mg od (n = 124) or 20 mg od (n = 94) or apixaban 5 mg bid (n = 52) measured at different time. Results Concentrations of rivaroxaban and apixaban in serum were about 20–25% higher compared with plasma samples with a high correlation (r = 0·79775–0·94662) using all assays (all P < 0·0001). The intraclass correlation coefficients were about 0·90 for rivaroxaban and 0·55 for apixaban. Mean rivaroxaban concentrations were higher at 2 and 3 h compared with 1 and 12 h after administration measured from plasma and serum samples (all P-values < 0·05) and were not different between 1 vs. 12 h (plasma and serum). Conclusions The results indicate that rivaroxaban and apixaban concentrations can be determined specifically from serum samples. PMID:24931429

  7. How is the weather? Forecasting inpatient glycemic control

    PubMed Central

    Saulnier, George E; Castro, Janna C; Cook, Curtiss B; Thompson, Bithika M

    2017-01-01

    Aim: Apply methods of damped trend analysis to forecast inpatient glycemic control. Method: Observed and calculated point-of-care blood glucose data trends were determined over 62 weeks. Mean absolute percent error was used to calculate differences between observed and forecasted values. Comparisons were drawn between model results and linear regression forecasting. Results: The forecasted mean glucose trends observed during the first 24 and 48 weeks of projections compared favorably to the results provided by linear regression forecasting. However, in some scenarios, the damped trend method changed inferences compared with linear regression. In all scenarios, mean absolute percent error values remained below the 10% accepted by demand industries. Conclusion: Results indicate that forecasting methods historically applied within demand industries can project future inpatient glycemic control. Additional study is needed to determine if forecasting is useful in the analyses of other glucometric parameters and, if so, how to apply the techniques to quality improvement. PMID:29134125

  8. Substitution of Fingertip Blood for Venous Blood in the Measurement of Hematocrit and Hemoglobin Following Exercise

    ERIC Educational Resources Information Center

    Fahey, Thomas D.; And Others

    1977-01-01

    Results from comparative testing indicate that fingertip blood is a valid indicator of antecubital venous hematocrit (hct) and hemoglobin (hgb), and that hct ratios determined on the Coulter counter are comparable to those found by the microhematocrit method. (MB)

  9. Comparison of the Experimental Performance of Ferroelectric CPW Circuits with Method of Moment Simulations and Conformal Mapping

    NASA Technical Reports Server (NTRS)

    VanKeuls, Fred W.; Chevalier, Chris T.; Miranda, Felix A.; Carlson, C. M.; Rivkin, T. V.; Parilla, P. A.; Perkins, J. D.; Ginley, D. S.

    2001-01-01

    Experimental measurements of coplanar waveguide (CPW) circuits atop thin films of ferroelectric Ba(x)Sr(1-x)TiO3 (BST) were made as a function bias from 0 to 200 V and frequency from 0.045 to 20 GHz. The resulting phase shifts are compared with method of moments electromagnetic simulations and a conformal mapping analysis to determine the dielectric constant of the BST films. Based on the correlation between the experimental and the modeled data, an analysis of the extent to which the electromagnetic simulators provide reliable values for the dielectric constant of the ferroelectric in these structures has been performed. In addition, to determine how well the modeled data compare with experimental data, the dielectric constant values were also compared to low frequency measurements of interdigitated capacitor circuits on the same films. Results of these comparisons will be presented.

  10. An assessment of some theoretical models used for the calculation of the refractive index of InXGa1-xAs

    NASA Astrophysics Data System (ADS)

    Engelbrecht, J. A. A.

    2018-04-01

    Theoretical models used for the determination of the refractive index of InXGa1-XAs are reviewed and compared. Attention is drawn to some problems experienced with some of the models. Models also extended to the mid-infrared region of the electromagnetic spectrum. Theoretical results in the mid-infrared region are then compared to previously published experimental results.

  11. Patient-specific dose calculations for pediatric CT of the chest, abdomen and pelvis

    PubMed Central

    Fraser, Nicholas D.; Carver, Diana E.; Pickens, David R.; Price, Ronald R.; Hernanz-Schulman, Marta; Stabin, Michael G.

    2015-01-01

    Background Organ dose is essential for accurate estimates of patient dose from CT. Objective To determine organ doses from a broad range of pediatric patients undergoing diagnostic chest–abdomen–pelvis CT and investigate how these relate to patient size. Materials and methods We used a previously validated Monte Carlo simulation model of a Philips Brilliance 64 multi-detector CT scanner (Philips Healthcare, Best, The Netherlands) to calculate organ doses for 40 pediatric patients (M:F=21:19; range 0.6–17 years). Organ volumes and positions were determined from the images using standard segmentation techniques. Non-linear regression was performed to determine the relationship between volume CT dose index (CTDIvol)-normalized organ doses and abdominopelvic diameter. We then compared results with values obtained from independent studies. Results We found that CTDIvol-normalized organ dose correlated strongly with exponentially decreasing abdominopelvic diameter (R2>0.8 for most organs). A similar relationship was determined for effective dose when normalized by dose-length product (R2=0.95). Our results agreed with previous studies within 12% using similar scan parameters (i.e. bowtie filter size, beam collimation); however results varied up to 25% when compared to studies using different bowtie filters. Conclusion Our study determined that organ doses can be estimated from measurements of patient size, namely body diameter, and CTDIvol prior to CT examination. This information provides an improved method for patient dose estimation. PMID:26142256

  12. Effect of paratuberculosis on culling, milk production, and milk quality in dairy herds.

    PubMed

    Hendrick, Steven H; Kelton, David F; Leslie, Ken E; Lissemore, Kerry D; Archambault, Marie; Duffield, Todd F

    2005-10-15

    To determine the effect of paratuberculosis on culling, milk production, and milk quality in infected dairy herds. Cross-sectional study. 689 lactating dairy cows in 9 herds. Milk, blood, and fecal samples were obtained from all cows. Fecal samples were evaluated via mycobacterial culture. Serum samples were tested with a commercially available ELISA for antibodies against Mycobacterium avium subsp paratuberculosis, and preserved milk samples were tested with an ELISA for antibodies against M paratuberculosis. Mixed effect and proportional hazards models were used to determine the effect of paratuberculosis on 305-day milk, fat, and protein production; somatic cell count linear score; and the risk of culling. Cows with positive results of bacteriologic culture of feces and milk ELISA produced less milk, fat, and protein, compared with herdmates with negative results. No difference in 305-day milk or fat production was detected in cows with positive results of serum ELISA, compared with seronegative cows. The 3 survival analyses revealed that cows with positive results of each test were at higher risk of being culled than cows with negative results. Paratuberculosis status, as determined by use of all 3 diagnostic tests, was not associated with milk somatic cell count linear score. Results suggest that for the 9 herds in this study, paratuberculosis significantly decreased milk production and cow longevity.

  13. Validation of numerical models for flow simulation in labyrinth seals

    NASA Astrophysics Data System (ADS)

    Frączek, D.; Wróblewski, W.

    2016-10-01

    CFD results were compared with the results of experiments for the flow through the labyrinth seal. RANS turbulence models (k-epsilon, k-omega, SST and SST-SAS) were selected for the study. Steady and transient results were analyzed. ANSYS CFX was used for numerical computation. The analysis included flow through sealing section with the honeycomb land. Leakage flows and velocity profiles in the seal were compared. In addition to the comparison of computational models, the divergence of modeling and experimental results has been determined. Tips for modeling these problems were formulated.

  14. Satellite orbit determination using quantum correlation technology

    NASA Astrophysics Data System (ADS)

    Zhang, Bo; Sun, Fuping; Zhu, Xinhui; Jia, Xiaolin

    2018-03-01

    After the presentation of second-order correlation ranging principles with quantum entanglement, the concept of quantum measurement is introduced to dynamic satellite precise orbit determination. Based on the application of traditional orbit determination models for correcting the systematic errors within the satellite, corresponding models for quantum orbit determination (QOD) are established. This paper experiments on QOD with the BeiDou Navigation Satellite System (BDS) by first simulating quantum observations of 1 day arc-length. Then the satellite orbits are resolved and compared with the reference precise ephemerides. Subsequently, some related factors influencing the accuracy of QOD are discussed. Furthermore, the accuracy for GEO, IGSO and MEO satellites increase about 20, 30 and 10 times, respectively, compared with the results from the resolution by measured data. Therefore, it can be expected that quantum technology may also bring delightful surprises to satellite orbit determination as have already emerged in other fields.

  15. Semiquantitative determination of mesophilic, aerobic microorganisms in cocoa products using the Soleris NF-TVC method.

    PubMed

    Montei, Carolyn; McDougal, Susan; Mozola, Mark; Rice, Jennifer

    2014-01-01

    The Soleris Non-fermenting Total Viable Count method was previously validated for a wide variety of food products, including cocoa powder. A matrix extension study was conducted to validate the method for use with cocoa butter and cocoa liquor. Test samples included naturally contaminated cocoa liquor and cocoa butter inoculated with natural microbial flora derived from cocoa liquor. A probability of detection statistical model was used to compare Soleris results at multiple test thresholds (dilutions) with aerobic plate counts determined using the AOAC Official Method 966.23 dilution plating method. Results of the two methods were not statistically different at any dilution level in any of the three trials conducted. The Soleris method offers the advantage of results within 24 h, compared to the 48 h required by standard dilution plating methods.

  16. Estimating terrestrial snow depth with the Topex-Poseidon altimeter and radiometer

    USGS Publications Warehouse

    Papa, F.; Legresy, B.; Mognard, N.M.; Josberger, E.G.; Remy, F.

    2002-01-01

    Active and passive microwave measurements obtained by the dual-frequency Topex-Poseidon radar altimeter from the Northern Great Plains of the United States are used to develop a snow pack radar backscatter model. The model results are compared with daily time series of surface snow observations made by the U.S. National Weather Service. The model results show that Ku-band provides more accurate snow depth determinations than does C-band. Comparing the snow depth determinations derived from the Topex-Poseidon nadir-looking passive microwave radiometers with the oblique-looking Satellite Sensor Microwave Imager (SSM/I) passive microwave observations and surface observations shows that both instruments accurately portray the temporal characteristics of the snow depth time series. While both retrievals consistently underestimate the actual snow depths, the Topex-Poseidon results are more accurate.

  17. Determinants of alveolar ridge preservation differ by anatomic location

    PubMed Central

    Leblebicioglu, Binnaz; Salas, Mabel; Ort, Yirae; Johnson, Ashley; Yildiz, Vedat O.; Kim, Do-Gyoon; Agarwal, Sudha; Tatakis, Dimitris N.

    2016-01-01

    Aim To investigate and compare outcomes following alveolar ridge preservation (ARP) in posterior maxilla and mandible. Methods Twenty-four patients (54 ± 3 years) with single posterior tooth extraction were included. ARP was performed with freeze-dried bone allograft and collagen membrane. Clinical parameters were recorded at extraction and re-entry. Harvested bone cores were analysed by microcomputed tomography (micro-CT), histomorphometry and immunohistochemistry. Results In both jaws, ARP prevented ridge height loss, but ridge width was significantly reduced by approximately 2.5 mm. Healing time, initial clinical attachment loss and amount of keratinized tissue at extraction site were identified as determinants of ridge height outcome. Buccal plate thickness and tooth root length were identified as determinants of ridge width outcome. In addition, initial ridge width was positively correlated with ridge width loss. Micro-CT revealed greater mineralization per unit volume in new bone compared with existing bone in mandible (p < 0.001). Distributions of residual graft, new cellular bone and immature tissue were similar in both jaws. Conclusion Within the limitations of this study, the results indicate that in different anatomic locations different factors may determine ARP outcomes. Further studies are needed to better understand determinants of ARP outcomes. PMID:23432761

  18. Models of determining deformations

    NASA Astrophysics Data System (ADS)

    Gladilin, V. N.

    2016-12-01

    In recent years, a lot of functions designed to determine deformation values that occur mostly as a result of settlement of structures and industrial equipment. Some authors suggest such advanced mathematical functions approximating deformations as general methods for the determination of deformations. The article describes models of deformations as physical processes. When comparing static, cinematic and dynamic models, it was found that the dynamic model reflects the deformation of structures and industrial equipment most reliably.

  19. TDRSS-user orbit determination using batch least-squares and sequential methods

    NASA Astrophysics Data System (ADS)

    Oza, D. H.; Jones, T. L.; Hakimi, M.; Samii, Mina V.; Doll, C. E.; Mistretta, G. D.; Hart, R. C.

    1993-02-01

    The Goddard Space Flight Center (GSFC) Flight Dynamics Division (FDD) commissioned Applied Technology Associates, Incorporated, to develop the Real-Time Orbit Determination/Enhanced (RTOD/E) system on a Disk Operating System (DOS)-based personal computer (PC) as a prototype system for sequential orbit determination of spacecraft. This paper presents the results of a study to compare the orbit determination accuracy for a Tracking and Data Relay Satellite System (TDRSS) user spacecraft, Landsat-4, obtained using RTOD/E, operating on a PC, with the accuracy of an established batch least-squares system, the Goddard Trajectory Determination System (GTDS), and operating on a mainframe computer. The results of Landsat-4 orbit determination will provide useful experience for the Earth Observing System (EOS) series of satellites. The Landsat-4 ephemerides were estimated for the January 17-23, 1991, timeframe, during which intensive TDRSS tracking data for Landsat-4 were available. Independent assessments were made of the consistencies (overlap comparisons for the batch case and covariances and the first measurement residuals for the sequential case) of solutions produced by the batch and sequential methods. The forward-filtered RTOD/E orbit solutions were compared with the definitive GTDS orbit solutions for Landsat-4; the solution differences were less than 40 meters after the filter had reached steady state.

  20. TDRSS-user orbit determination using batch least-squares and sequential methods

    NASA Technical Reports Server (NTRS)

    Oza, D. H.; Jones, T. L.; Hakimi, M.; Samii, Mina V.; Doll, C. E.; Mistretta, G. D.; Hart, R. C.

    1993-01-01

    The Goddard Space Flight Center (GSFC) Flight Dynamics Division (FDD) commissioned Applied Technology Associates, Incorporated, to develop the Real-Time Orbit Determination/Enhanced (RTOD/E) system on a Disk Operating System (DOS)-based personal computer (PC) as a prototype system for sequential orbit determination of spacecraft. This paper presents the results of a study to compare the orbit determination accuracy for a Tracking and Data Relay Satellite System (TDRSS) user spacecraft, Landsat-4, obtained using RTOD/E, operating on a PC, with the accuracy of an established batch least-squares system, the Goddard Trajectory Determination System (GTDS), and operating on a mainframe computer. The results of Landsat-4 orbit determination will provide useful experience for the Earth Observing System (EOS) series of satellites. The Landsat-4 ephemerides were estimated for the January 17-23, 1991, timeframe, during which intensive TDRSS tracking data for Landsat-4 were available. Independent assessments were made of the consistencies (overlap comparisons for the batch case and covariances and the first measurement residuals for the sequential case) of solutions produced by the batch and sequential methods. The forward-filtered RTOD/E orbit solutions were compared with the definitive GTDS orbit solutions for Landsat-4; the solution differences were less than 40 meters after the filter had reached steady state.

  1. The determination of viscosity at liquid mixtures - Comparison of approaches

    NASA Astrophysics Data System (ADS)

    Michal, Schmirler; Hana, Netřebská; Jan, Kolínský

    2017-09-01

    The research of flow field parameters for non-stationary flow of non-Newtonian fluids carried out at the Institute of Fluid Mechanics and Thermodynamics of CTU showed the need for knowledge of determination of the resulting viscosity of a mixture of several liquids. There are several sources for determining viscosity of mixtures. It is possible either to find theoretical relations in the literature or use technical tables based on experimentally measured data. This article focuses on comparing these approaches with an experiment. The experiment was performed by a Rheotest RN 4.1 rotating viscometer produced by the company RHEOTEST Medingen. The research was carried out using a solution of glycerol and water. The research has shown great differences in results in different approaches for determining the viscosity of the liquid mixtures. The result of this paper is to determine the method of viscosity calculation that is closest to the experimental data.

  2. Performance of a Modern Glucose Meter in ICU and General Hospital Inpatients: 3 Years of Real-World Paired Meter and Central Laboratory Results.

    PubMed

    Zhang, Ray; Isakow, Warren; Kollef, Marin H; Scott, Mitchell G

    2017-09-01

    Due to accuracy concerns, the Food and Drug Administration issued guidances to manufacturers that resulted in Center for Medicare and Medicaid Services stating that the use of meters in critically ill patients is "off-label" and constitutes "high complexity" testing. This is causing significant workflow problems in ICUs nationally. We wished to determine whether real-world accuracy of modern glucose meters is worse in ICU patients compared with non-ICU inpatients. We reviewed glucose results over the preceding 3 years, comparing results from paired glucose meter and central laboratory tests performed within 60 minutes of each other in ICU versus non-ICU settings. Seven ICU and 30 non-ICU wards at a 1,300-bed academic hospital in the United States. A total of 14,763 general medicine/surgery inpatients and 20,970 ICU inpatients. None. Compared meter results with near simultaneously performed laboratory results from the same patient by applying the 2016 U.S. Food and Drug Administration accuracy criteria, determining mean absolute relative difference and examining where paired results fell within the Parkes consensus error grid zones. A higher percentage of glucose meter results from ICUs than from non-ICUs passed 2016 Food and Drug Administration accuracy criteria (p < 10) when comparing meter results with laboratory results. At 1 minute, no meter result from ICUs posed dangerous or significant risk by error grid analysis, whereas at 10 minutes, less than 0.1% of ICU meter results did, which was not statistically different from non-ICU results. Real-world accuracy of modern glucose meters is at least as accurate in the ICU setting as in the non-ICU setting at our institution.

  3. Induction of osteoporosis with its influence on osteoporotic determinants and their interrelationships in rats by DEXA

    PubMed Central

    Heiss, Christian; Govindarajan, Parameswari; Schlewitz, Gudrun; Hemdan, Nasr Y.A.; Schliefke, Nathalie; Alt, Volker; Thormann, Ulrich; Lips, Katrin Susanne; Wenisch, Sabine; Langheinrich, Alexander C.; Zahner, Daniel; Schnettler, Reinhard

    2012-01-01

    Summary Background As women are the population most affected by multifactorial osteoporosis, research is focused on unraveling the underlying mechanism of osteoporosis induction in rats by combining ovariectomy (OVX) either with calcium, phosphorus, vitamin C and vitamin D2/D3 deficiency, or by administration of glucocorticoid (dexamethasone). Material/Methods Different skeletal sites of sham, OVX-Diet and OVX-Steroid rats were analyzed by Dual Energy X-ray Absorptiometry (DEXA) at varied time points of 0, 4 and 12 weeks to determine and compare the osteoporotic factors such as bone mineral density (BMD), bone mineral content (BMC), area, body weight and percent fat among different groups and time points. Comparative analysis and interrelationships among osteoporotic determinants by regression analysis were also determined. Results T scores were below-2.5 in OVX-Diet rats at 4 and 12 weeks post-OVX. OVX-diet rats revealed pronounced osteoporotic status with reduced BMD and BMC than the steroid counterparts, with the spine and pelvis as the most affected skeletal sites. Increase in percent fat was observed irrespective of the osteoporosis inducers applied. Comparative analysis and interrelationships between osteoporotic determinants that are rarely studied in animals indicate the necessity to analyze BMC and area along with BMD in obtaining meaningful information leading to proper prediction of probability of osteoporotic fractures. Conclusions Enhanced osteoporotic effect observed in OVX-Diet rats indicates that estrogen dysregulation combined with diet treatment induces and enhances osteoporosis with time when compared to the steroid group. Comparative and regression analysis indicates the need to determine BMC along with BMD and area in osteoporotic determination. PMID:22648240

  4. Experimental and analytical determination of stability parameters for a balloon tethered in a wind

    NASA Technical Reports Server (NTRS)

    Redd, L. T.; Bennett, R. M.; Bland, S. R.

    1973-01-01

    Experimental and analytical techniques for determining stability parameters for a balloon tethered in a steady wind are described. These techniques are applied to a particular 7.64-meter-long balloon, and the results are presented. The stability parameters of interest appear as coefficients in linearized stability equations and are derived from the various forces and moments acting on the balloon. In several cases the results from the experimental and analytical techniques are compared and suggestions are given as to which techniques are the most practical means of determining values for the stability parameters.

  5. Evaluation of nutrient quality-assurance data for Alexanders and Mount Rock Spring basins, Cumberland County, Pennsylvania

    USGS Publications Warehouse

    Witt, E. C.; Hippe, D.J.; Giovannitti, R.M.

    1992-01-01

    A total of 304 nutrient samples were collected from May 1990 through September 1991 to determine concentrations and loads of nutrients in water discharged from two spring basins in Cumberland County, Pa. Fifty-four percent of these nutrient samples were for the evaluation of (1) laboratory consistency, (2) container and preservative cleanliness, (3) maintenance of analyte representativeness as affected by three different preservation methods, and (4) comparison of analyte results with the "Most Probable Value" for Standard Reference Water Samples. Results of 37 duplicate analyses indicate that the Pennsylvania Department of Environmental Resources, Bureau of Laboratories (principal laboratory) remained within its ±10 percent goal for all but one analyte. Results of the blank analysis show that the sampling containers did not compromise the water quality. However, mercuric-chloride-preservation blanks apparently contained measurable ammonium in four of five samples and ammonium plus organic nitrogen in two of five samples. Interlaboratory results indicate substantial differences in the determination of nitrate and ammonium plus organic nitrogen between the principal laboratory and the U.S. Geological Survey National Water-Quality Laboratory. In comparison with the U.S. Environmental Protection Agency Quality-Control Samples, the principal laboratory was sufficiently accurate in its determination of nutrient anafytes. Analysis of replicate samples indicated that sulfuric-acid preservative best maintained the representativeness of the anafytes nitrate and ammonium plus organic nitrogen, whereas, mercuric chloride best maintained the representativeness of orthophosphate. Comparison of nutrient analyte determinations with the Most Probable Value for each preservation method shows that two of five analytes with no chemical preservative compare well, three of five with mercuric-chloride preservative compare well, and three of five with sulfuricacid preservative compare well.

  6. Clinical assessment of blood glucose homeostasis in horses: comparison of a continuous glucose monitoring system with a combined intravenous glucose and insulin test protocol.

    PubMed

    Johnson, P J; Wiedmeyer, C E; LaCarrubba, A; Messer, N T; Dingfelder, H A; Cogswell, A M; Amorim, J R R; Ganjam, V K

    2011-01-01

    The combined glucose-insulin test (CGIT) is helpful for evaluating insulin sensitivity. A continuous glucose monitoring system (CGMS) reports changes in interstitial glucose concentrations as they occur in the blood. Use of the CGMS minimizes animal contact and may be useful when performing a CGIT. Results obtained using a CGMS are useful for the evaluation of glucose responses during the evaluation of insulin sensitivity in equids. Seven mature, obese ponies. Ponies were equipped with CGMS for determination of interstitial glucose concentrations. Glucose (150 mg/kg, i.v.) and insulin (0.1 U/kg, i.v.) were administered and blood glucose concentrations determined at (minutes after time zero) 1, 5, 15, 25, 35, 45, 60, 75, 90, 105, and 120 with a hand-held glucometer. Blood chemistry results were compared with simultaneously obtained results using CGMS. Concordance coefficients determined for comparison of blood glucose concentrations determined by a hand-held glucometer and those determined by CGMS after the zero time point were 0.623, 0.764, 0.834, 0.854, and 0.818 (for delays of 0, 5, 10, 15, and 20 minutes, respectively). Interstitial glucose concentrations obtained by the CGMS compared favorably to blood glucose concentrations. CGMS may be useful for assessment of glucose dynamics in the CGIT. Copyright © 2010 by the American College of Veterinary Internal Medicine.

  7. Problems of comparing blood glucose molality and molarity determined with an Omni, an EML 105 and an Ebio analyser.

    PubMed

    Haeckel, Rainer; Hänecke, Petra

    2003-07-01

    The comparability between glucose concentrations measured in various sample systems is still a matter of debate. Decision limits are usually determined in venous plasma and then converted to either blood or to the aqueous compartment (activity). The conversion factors recommended have not yet been generally accepted. In the present study, glucose concentrations were determined in blood and plasma with an Ebio analyser (molarity) and in the aqueous compartment with both an EML 105 and an Omni (molality). All analytical results were referred to the same aqueous standard solution. The Ebio results agreed with reference method values in control materials. Concentrations determined in the various sample systems from patients (molarity) correlated well with the molality values measured either with the EML or the Omni. However, the mean values of the EML were not consistent with those derived theoretically by considering the different water content. With the Omni, only molality values in whole blood appeared plausible, but not in plasma, although the two sample systems should provide identical molality values. The EML results were almost identical in whole blood and plasma. Theoretically, glucose molality would be the ideal diagnostic quantity. However, no diagnostic advantage of molality determined in whole blood with the Omni vs. molarity values could be detected in a group of 40 non-diabetic and 27 diabetic subjects.

  8. Crack closure, a literature study

    NASA Astrophysics Data System (ADS)

    Holmgren, M.

    1993-08-01

    In this report crack closure is treated. The state of the art is reviewed. Different empirical formulas for determining the crack closure are compared with each other, and their benefits are discussed. Experimental techniques for determining the crack closure stress are discussed, and some results from fatigue tests are also reported. Experimental data from the literature are reported.

  9. The Determination of Heat Capacity Ratios in a Simple Open System

    ERIC Educational Resources Information Center

    Holden, Glen L.

    2007-01-01

    A virtually closed system is treated as open and compared to known results. The classic experiment of Clement and Desormes provides the conceptual framework for this open system approach in determining the molar heat capacity ratios, lambda. This alternate view, extends the theoretical treatment beyond the first law of thermodynamics for closed…

  10. Galvanic Cells and the Determination of Equilibrium Constants

    ERIC Educational Resources Information Center

    Brosmer, Jonathan L.; Peters, Dennis G.

    2012-01-01

    Readily assembled mini-galvanic cells can be employed to compare their observed voltages with those predicted from the Nernst equation and to determine solubility products for silver halides and overall formation constants for metal-ammonia complexes. Results obtained by students in both an honors-level first-year course in general chemistry and…

  11. Buckling of beams supported by Pasternak foundation.

    NASA Technical Reports Server (NTRS)

    Murthy, G. K. N.

    1973-01-01

    The determination of buckling loads for infinitely long beams resting on a Pasternak (1954) foundation is considered. It is assumed that the onset of buckling takes place at neutral equilibrium. The effect of extending the foundation beyond the width of the beam is determined by comparing the results obtained for two- and three-dimensional foundations.

  12. Indicators of College Readiness: A Comparison of High School and College Measures

    ERIC Educational Resources Information Center

    Connolly, Faith; Olson, Linda S.; Durham, Rachel E.; Plank, Stephen B.

    2014-01-01

    This report compares high school indicators of college readiness for the Baltimore City Schools Class of 2011 with actual readiness as determined by Maryland colleges. Each Maryland college determines its own criteria for entering credit bearing courses or taking developmental courses. As a result, findings are reported separately by college…

  13. Evaluating Serious Games through User Experience and Performance Assessment

    ERIC Educational Resources Information Center

    Barton, Irving Gary, Jr.

    2017-01-01

    Military education is held to high standards for our servicemen and women. The purpose of this quantitative, comparative study was to determine if significant differences existed in learning styles relative to military experience as determined by learning in a serious game environment. Study results are expected to advance the state of research in…

  14. Evaluation of the pulse-contour method of determining stroke volume in man.

    NASA Technical Reports Server (NTRS)

    Alderman, E. L.; Branzi, A.; Sanders, W.; Brown, B. W.; Harrison, D. C.

    1972-01-01

    The pulse-contour method for determining stroke volume has been employed as a continuous rapid method of monitoring the cardiovascular status of patients. Twenty-one patients with ischemic heart disease and 21 patients with mitral valve disease were subjected to a variety of hemodynamic interventions. The pulse-contour estimations, using three different formulas derived by Warner, Kouchoukos, and Herd, were compared with indicator-dilution outputs. A comparison of the results of the two methods for determining stroke volume yielded correlation coefficients ranging from 0.59 to 0.84. The better performing Warner formula yielded a coefficient of variation of about 20%. The type of hemodynamic interventions employed did not significantly affect the results using the pulse-contour method. Although the correlation of the pulse-contour and indicator-dilution stroke volumes is high, the coefficient of variation is such that small changes in stroke volume cannot be accurately assessed by the pulse-contour method. However, the simplicity and rapidity of this method compared to determination of cardiac output by Fick or indicator-dilution methods makes it a potentially useful adjunct for monitoring critically ill patients.

  15. Evaluation of well-purging effects on water-quality results for samples collected from the eastern Snake River Plain aquifer underlying the Idaho National Laboratory, Idaho

    USGS Publications Warehouse

    Knobel, LeRoy L.

    2006-01-01

    This report presents qualitative and quantitative comparisons of water-quality data from the Idaho National Laboratory, Idaho, to determine if the change from purging three wellbore volumes to one wellbore volume has a discernible effect on the comparability of the data. Historical water-quality data for 30 wells were visually compared to water-quality data collected after purging only 1 wellbore volume from the same wells. Of the 322 qualitatively examined constituent plots, 97.5 percent met 1 or more of the criteria established for determining data comparability. A simple statistical equation to determine if water-quality data collected from 28 wells at the INL with long purge times (after pumping 1 and 3 wellbore volumes of water) were statistically the same at the 95-percent confidence level indicated that 97.9 percent of 379 constituent pairs were equivalent. Comparability of water-quality data determined from both the qualitative (97.5 percent comparable) and quantitative (97.9 percent comparable) evaluations after purging 1 and 3 wellbore volumes of water indicates that the change from purging 3 to 1 wellbore volumes had no discernible effect on comparability of water-quality data at the INL. However, the qualitative evaluation was limited because only October-November 2003 data were available for comparison to historical data. This report was prepared by the U.S. Geological Survey in cooperation with the U.S. Department of Energy.

  16. Methods for comparative evaluation of propulsion system designs for supersonic aircraft

    NASA Technical Reports Server (NTRS)

    Tyson, R. M.; Mairs, R. Y.; Halferty, F. D., Jr.; Moore, B. E.; Chaloff, D.; Knudsen, A. W.

    1976-01-01

    The propulsion system comparative evaluation study was conducted to define a rapid, approximate method for evaluating the effects of propulsion system changes for an advanced supersonic cruise airplane, and to verify the approximate method by comparing its mission performance results with those from a more detailed analysis. A table look up computer program was developed to determine nacelle drag increments for a range of parametric nacelle shapes and sizes. Aircraft sensitivities to propulsion parameters were defined. Nacelle shapes, installed weights, and installed performance was determined for four study engines selected from the NASA supersonic cruise aircraft research (SCAR) engine studies program. Both rapid evaluation method (using sensitivities) and traditional preliminary design methods were then used to assess the four engines. The method was found to compare well with the more detailed analyses.

  17. N-Terminal Amino Acid Sequence Determination of Proteins by N-Terminal Dimethyl Labeling: Pitfalls and Advantages When Compared with Edman Degradation Sequence Analysis.

    PubMed

    Chang, Elizabeth; Pourmal, Sergei; Zhou, Chun; Kumar, Rupesh; Teplova, Marianna; Pavletich, Nikola P; Marians, Kenneth J; Erdjument-Bromage, Hediye

    2016-07-01

    In recent history, alternative approaches to Edman sequencing have been investigated, and to this end, the Association of Biomolecular Resource Facilities (ABRF) Protein Sequencing Research Group (PSRG) initiated studies in 2014 and 2015, looking into bottom-up and top-down N-terminal (Nt) dimethyl derivatization of standard quantities of intact proteins with the aim to determine Nt sequence information. We have expanded this initiative and used low picomole amounts of myoglobin to determine the efficiency of Nt-dimethylation. Application of this approach on protein domains, generated by limited proteolysis of overexpressed proteins, confirms that it is a universal labeling technique and is very sensitive when compared with Edman sequencing. Finally, we compared Edman sequencing and Nt-dimethylation of the same polypeptide fragments; results confirm that there is agreement in the identity of the Nt amino acid sequence between these 2 methods.

  18. Material Models for the Human Torso Finite Element Model

    DTIC Science & Technology

    2018-04-04

    material characterizations drawn from current literature. Biofidelity of the ARL torso was determined by comparing peak force, force-displacement, peak...Flesh simulation. The soft tissue mesh in the upper neck was highly distorted at 21.2 ms (right) compared to the original mesh (left...a realistic response with results comparable to physical experiments to support future efforts to evaluate BABT. 2. Methods 2.1 Review of

  19. Numerical modeling of the strain of elastic rubber elements

    NASA Astrophysics Data System (ADS)

    Moskvichev, E. N.; Porokhin, A. V.; Shcherbakov, I. V.

    2017-11-01

    A comparative analysis of the results of experimental investigation of mechanical behavior of the rubber sample during biaxial compression testing and numerical simulation results obtained by the finite element method was carried out to determine the correctness of the model applied in the engineering calculations of elastic structural elements made of the rubber. The governing equation represents the five-parameter Mooney-Rivlin model with the constants determined from experimental data. The investigation results showed that these constants reliably describe the mechanical behavior of the material under consideration. The divergence of experimental and numerical results does not exceed 15%.

  20. Validation and upgrading of physically based mathematical models

    NASA Technical Reports Server (NTRS)

    Duval, Ronald

    1992-01-01

    The validation of the results of physically-based mathematical models against experimental results was discussed. Systematic techniques are used for: (1) isolating subsets of the simulator mathematical model and comparing the response of each subset to its experimental response for the same input conditions; (2) evaluating the response error to determine whether it is the result of incorrect parameter values, incorrect structure of the model subset, or unmodeled external effects of cross coupling; and (3) modifying and upgrading the model and its parameter values to determine the most physically appropriate combination of changes.

  1. Dynamics of Debris Motion and the Collision Hazard to Spacecraft Resulting from an Orbital Breakup

    DTIC Science & Technology

    1988-01-01

    Time, Clohessy - Wiltshire and Torus Approximation ....................................... 44 21. J2 Parameters, C1 , C2 , C3, versus Av; 200-nmi...revolving about the same gravitational attracting mass is the Clohessy - Wiltshire equations. In matrix form, the analytical solution is 38 r 42 x I 6(wt...can determine the range of validity of the Clohessy - Wiltshire equations. 3.3 RESULTS The range of validity can be determined by comparing the effects

  2. Review of lattice results concerning low-energy particle physics: Flavour Lattice Averaging Group (FLAG).

    PubMed

    Aoki, S; Aoki, Y; Bečirević, D; Bernard, C; Blum, T; Colangelo, G; Della Morte, M; Dimopoulos, P; Dürr, S; Fukaya, H; Golterman, M; Gottlieb, Steven; Hashimoto, S; Heller, U M; Horsley, R; Jüttner, A; Kaneko, T; Lellouch, L; Leutwyler, H; Lin, C-J D; Lubicz, V; Lunghi, E; Mawhinney, R; Onogi, T; Pena, C; Sachrajda, C T; Sharpe, S R; Simula, S; Sommer, R; Vladikas, A; Wenger, U; Wittig, H

    2017-01-01

    We review lattice results related to pion, kaon, D - and B -meson physics with the aim of making them easily accessible to the particle-physics community. More specifically, we report on the determination of the light-quark masses, the form factor [Formula: see text], arising in the semileptonic [Formula: see text] transition at zero momentum transfer, as well as the decay constant ratio [Formula: see text] and its consequences for the CKM matrix elements [Formula: see text] and [Formula: see text]. Furthermore, we describe the results obtained on the lattice for some of the low-energy constants of [Formula: see text] and [Formula: see text] Chiral Perturbation Theory. We review the determination of the [Formula: see text] parameter of neutral kaon mixing as well as the additional four B parameters that arise in theories of physics beyond the Standard Model. The latter quantities are an addition compared to the previous review. For the heavy-quark sector, we provide results for [Formula: see text] and [Formula: see text] (also new compared to the previous review), as well as those for D - and B -meson-decay constants, form factors, and mixing parameters. These are the heavy-quark quantities most relevant for the determination of CKM matrix elements and the global CKM unitarity-triangle fit. Finally, we review the status of lattice determinations of the strong coupling constant [Formula: see text].

  3. An Admittance Survey of Large Volcanoes on Venus: Implications for Volcano Growth

    NASA Technical Reports Server (NTRS)

    Brian, A. W.; Smrekar, S. E.; Stofan, E. R.

    2004-01-01

    Estimates of the thickness of the venusian crust and elastic lithosphere are important in determining the rheological and thermal properties of Venus. These estimates offer insights into what conditions are needed for certain features, such as large volcanoes and coronae, to form. Lithospheric properties for much of the large volcano population on Venus are not well known. Previous studies of elastic thickness (Te) have concentrated on individual or small groups of edifices, or have used volcano models and fixed values of Te to match with observations of volcano morphologies. In addition, previous studies use different methods to estimate lithospheric parameters meaning it is difficult to compare their results. Following recent global studies of the admittance signatures exhibited by the venusian corona population, we performed a similar survey into large volcanoes in an effort to determine the range of lithospheric parameters shown by these features. This survey of the entire large volcano population used the same method throughout so that all estimates could be directly compared. By analysing a large number of edifices and comparing our results to observations of their morphology and models of volcano formation, we can help determine the controlling parameters that govern volcano growth on Venus.

  4. Antacid effects of Chinese herbal prescriptions assessed by a modified artificial stomach model

    PubMed Central

    Wu, Tsung-Hsiu; Chen, I-Chin; Chen, Lih-Chi

    2010-01-01

    AIM: To assess the antacid effects of the tonic Chinese herbal prescriptions, Si-Jun-Zi-Tang (SJZT) and Shen-Ling-Bai-Zhu-San (SLBZS). METHODS: Decoctions of the tonic Chinese herbal prescriptions, SJZT and SLBZS, were prepared according to Chinese original documents. The pH of the prescription decoctions and their neutralizing effects on artificial gastric acids were determined and compared with water and the active controls, sodium bicarbonate and colloidal aluminum phosphate. A modified model of Vatier’s artificial stomach was used to determine the duration of consistent neutralization effect on artificial gastric acids. The neutralization capacity in vitro was determined with the titration method of Fordtran’s model. RESULTS: The results showed that both SJZT and SLBZS have antacid effects in vitro. Compared with the water group, SJZT and SLBZS were found to possess significant gastric acid neutralizing effects. The duration for consistent neutralization of SLBZS was significantly longer than that of water. Also, SLBZS and SJZT exhibited significant antacid capacities compared to water. CONCLUSION: SJZT and SLBZS were consistently active in the artificial stomach model and are suggested to have antacid effects similar to the active control drugs. PMID:20845514

  5. Efficiently estimating salmon escapement uncertainty using systematically sampled data

    USGS Publications Warehouse

    Reynolds, Joel H.; Woody, Carol Ann; Gove, Nancy E.; Fair, Lowell F.

    2007-01-01

    Fish escapement is generally monitored using nonreplicated systematic sampling designs (e.g., via visual counts from towers or hydroacoustic counts). These sampling designs support a variety of methods for estimating the variance of the total escapement. Unfortunately, all the methods give biased results, with the magnitude of the bias being determined by the underlying process patterns. Fish escapement commonly exhibits positive autocorrelation and nonlinear patterns, such as diurnal and seasonal patterns. For these patterns, poor choice of variance estimator can needlessly increase the uncertainty managers have to deal with in sustaining fish populations. We illustrate the effect of sampling design and variance estimator choice on variance estimates of total escapement for anadromous salmonids from systematic samples of fish passage. Using simulated tower counts of sockeye salmon Oncorhynchus nerka escapement on the Kvichak River, Alaska, five variance estimators for nonreplicated systematic samples were compared to determine the least biased. Using the least biased variance estimator, four confidence interval estimators were compared for expected coverage and mean interval width. Finally, five systematic sampling designs were compared to determine the design giving the smallest average variance estimate for total annual escapement. For nonreplicated systematic samples of fish escapement, all variance estimators were positively biased. Compared to the other estimators, the least biased estimator reduced bias by, on average, from 12% to 98%. All confidence intervals gave effectively identical results. Replicated systematic sampling designs consistently provided the smallest average estimated variance among those compared.

  6. Accurate determination of the diffusion coefficient of proteins by Fourier analysis with whole column imaging detection.

    PubMed

    Zarabadi, Atefeh S; Pawliszyn, Janusz

    2015-02-17

    Analysis in the frequency domain is considered a powerful tool to elicit precise information from spectroscopic signals. In this study, the Fourier transformation technique is employed to determine the diffusion coefficient (D) of a number of proteins in the frequency domain. Analytical approaches are investigated for determination of D from both experimental and data treatment viewpoints. The diffusion process is modeled to calculate diffusion coefficients based on the Fourier transformation solution to Fick's law equation, and its results are compared to time domain results. The simulations characterize optimum spatial and temporal conditions and demonstrate the noise tolerance of the method. The proposed model is validated by its application for the electropherograms from the diffusion path of a set of proteins. Real-time dynamic scanning is conducted to monitor dispersion by employing whole column imaging detection technology in combination with capillary isoelectric focusing (CIEF) and the imaging plug flow (iPF) experiment. These experimental techniques provide different peak shapes, which are utilized to demonstrate the Fourier transformation ability in extracting diffusion coefficients out of irregular shape signals. Experimental results confirmed that the Fourier transformation procedure substantially enhanced the accuracy of the determined values compared to those obtained in the time domain.

  7. Comparison of Saliva Collection Methods for the Determination of Salivary Cortisol Levels in Rhesus Macaques (Macaca mulatta), Cynomolgus Macaques (Macaca fascicularis), and African Green Monkeys (Chlorocebus aethiops)

    PubMed Central

    Rapp-Santos, Kamala J; Altamura, Louis A; Norris, Sarah L; Lugo-Roman, Luis A; Rico, Pedro J; Hofer, Christian C

    2017-01-01

    The ability to quickly and accurately determine cortisol as a biomarker for stress is a valuable tool in assessing the wellbeing of NHP. In this study, 2 methods of collecting saliva (a commercial collection device and passive drool) and the resulting free salivary cortisol levels were compared with total serum cortisol concentration in rhesus macaques (Macaca mulatta), cynomolgus macaques (Macaca fascicularis) and African green monkeys (Chlorocebus aethiops) at 2 collection time points. Serum and salivary cortisol levels were determined using a competitive quantitative ELISA. In addition, both saliva collection methods were evaluated for volume collected and ease of use. Compared with passive drool, the experimental collection device was more reliable in collecting sufficient volumes of saliva, and the resulting salivary cortisol values demonstrated stronger correlation with serum cortisol concentration in all species and collection days except cynomolgus macaques on day 1. This saliva collection device allows quick and reliable sample collection for the determination of salivary cortisol levels. In addition, the results might provide a useful tool for evaluating hypothalamic-pituitary-adrenal axis activity or the physiologic stress reaction in NHP as well as a biomarker of psychologic stress states in a variety of situations. PMID:28315649

  8. Total reflection X-ray Fluorescence determination of interfering elements rubidium and uranium by profile fitting

    NASA Astrophysics Data System (ADS)

    Dhara, Sangita; Khooha, Ajay; Singh, Ajit Kumar; Tiwari, M. K.; Misra, N. L.

    2018-06-01

    Systematic studies to assess the analytical parameters obtained in the total reflection X-ray fluorescence (TXRF) determinations of interfering elements Rb and U using profile fitting are reported in the present manuscript. The X-ray lines Rb Kα and U Lα having serious spectral interference (ΔE = 218 eV), have been used as analytical lines. The intensities of these X-ray lines have been assessed using profile fitting. In order to compare the analytical results of Rb determinations in presence of U, with and without U excitation, synchrotron radiation was tuned to energy just above and below the U Labs edge. This approach shall excite both Rb Kα and U Lα simultaneously and Rb Kα selectively. Finally, the samples were also analyzed with a laboratory based TXRF spectrometer. The analytical results obtained in all these conditions were comparable. The authenticity of the results was assessed by analyzing U with respect to Rb in Rb2U(SO4)3, a standard reference material for U. The average precision obtained for TXRF determinations was below 3% (RSD, n = 3, 1σ) and the percent deviation of TXRF values from the expected values calculated on the basis of sample preparation was within 3%.

  9. Subtotal resection of vestibular schwannoma: Evaluation with Ki-67 measurement, magnetic resonance imaging, and long-term observation

    PubMed Central

    Iannella, Giannicola; de Vincentiis, Marco; Di Gioia, Cira; Carletti, Raffaella; Pasquariello, Benedetta; Manno, Alessandra; Angeletti, Diletta; Savastano, Ersilia; Magliulo, Giuseppe

    2017-01-01

    Purpose The aim of this study was to compare the postoperative clinical and radiological data of patients with vestibular schwannomas who were initially managed by near total resection (NTR) or subtotal resection (STR). The Ki-67 analysis results were compared with tumor regrowth to determine the presence of a correlation between this proliferative index and postoperative tumor regrowth. Study Design Seventeen adult patients (7 male, 10 female) were retrospectively reviewed. Nine (52.9%) and eight (47.1%) patients underwent NTR and STR, respectively. Postoperative clinical and radiological data associated with vestibular schwannoma growth were compared with the Ki-67 immunohistochemical analysis results. Results Evidence of clinically significant regrowth was observed in four (23.5%) patients. Patients who underwent NTR had a lower rate/incidence of tumor regrowth than did patients who underwent STR. Patients with a higher Ki-67 index had the highest tumor regrowth rates. Conclusions Our study indicates that assessment of the Ki-67 index may be useful for determining the probability of regrowth of vestibular schwannomas when only partial removal is accomplished. PMID:28447494

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kurnik, Charles W.; Stoughton, Kate M; Figueroa, Jorge

    This measurement and verification (M&V) protocol provides procedures for energy service companies (ESCOs) and water efficiency service companies (WESCOs) to determine water savings resulting from water conservation measures (WCMs) in energy performance contracts associated with outdoor irrigation efficiency projects. The water savings are determined by comparing the baseline water use to the water use after the WCM has been implemented. This protocol outlines the basic structure of the M&V plan, and details the procedures to use to determine water savings.

  11. Application of Reverse Transcriptase -PCR (RT-PCR) for rapid detection of viable Escherichia coli in drinking water samples.

    PubMed

    Molaee, Neda; Abtahi, Hamid; Ghannadzadeh, Mohammad Javad; Karimi, Masoude; Ghaznavi-Rad, Ehsanollah

    2015-01-01

    Polymerase chain reaction (PCR) is preferred to other methods for detecting Escherichia coli (E. coli) in water in terms of speed, accuracy and efficiency. False positive result is considered as the major disadvantages of PCR. For this reason, reverse transcriptase-polymerase chain reaction (RT-PCR) can be used to solve this problem. The aim of present study was to determine the efficiency of RT-PCR for rapid detection of viable Escherichia coli in drinking water samples and enhance its sensitivity through application of different filter membranes. Specific primers were designed for 16S rRNA and elongation Factor II genes. Different concentrations of bacteria were passed through FHLP and HAWP filters. Then, RT-PCR was performed using 16srRNA and EF -Tu primers. Contamination of 10 wells was determined by RT-PCR in Arak city. To evaluate RT-PCR efficiency, the results were compared with most probable number (MPN) method. RT-PCR is able to detect bacteria in different concentrations. Application of EF II primers reduced false positive results compared to 16S rRNA primers. The FHLP hydrophobic filters have higher ability to absorb bacteria compared with HAWB hydrophilic filters. So the use of hydrophobic filters will increase the sensitivity of RT-PCR. RT-PCR shows a higher sensitivity compared to conventional water contamination detection method. Unlike PCR, RT-PCR does not lead to false positive results. The use of EF-Tu primers can reduce the incidence of false positive results. Furthermore, hydrophobic filters have a higher ability to absorb bacteria compared to hydrophilic filters.

  12. Smartphone assessment of knee flexion compared to radiographic standards.

    PubMed

    Dietz, Matthew J; Sprando, Daniel; Hanselman, Andrew E; Regier, Michael D; Frye, Benjamin M

    2017-03-01

    Measuring knee range of motion (ROM) is an important assessment for the outcomes of total knee arthroplasty. Recent technological advances have led to the development and use of accelerometer-based smartphone applications to measure knee ROM. The purpose of this study was to develop, standardize, and validate methods of utilizing smartphone accelerometer technology compared to radiographic standards, visual estimation, and goniometric evaluation. Participants used visual estimation, a long-arm goniometer, and a smartphone accelerometer to determine range of motion of a cadaveric lower extremity; these results were compared to radiographs taken at the same angles. The optimal smartphone position was determined to be on top of the leg at the distal femur and proximal tibia location. Between methods, it was found that the smartphone and goniometer were comparably reliable in measuring knee flexion (ICC=0.94; 95% CI: 0.91-0.96). Visual estimation was found to be the least reliable method of measurement. The results suggested that the smartphone accelerometer was non-inferior when compared to the other measurement techniques, demonstrated similar deviations from radiographic standards, and did not appear to be influenced by the person performing the measurements or the girth of the extremity. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Does Authoritarian "Big Stick" Counseling Get Results With Unemployed Youth?

    ERIC Educational Resources Information Center

    Jarvis, Donald L.

    This study compared both the degree of authoritarianism exhibited by school counselors as compared to other helping gorups, and the extent to which authoritarian counselors were successful. The latter was determined by the number of youths who did find employment. The study found that school counselors were significantly more authoritarian than…

  14. A Study of Assessments Designed for Student Success

    ERIC Educational Resources Information Center

    Delepine, Sidney G., III

    2012-01-01

    The purpose of this quantitative study is to compare a new assessment tool, the SkillsUSA Connect Assessment with the NOCTI assessment to determine which test results in more students achieving success. A quantitative study, designed to compare test scores of students taking the NOCTI assessment and new assessments from SkillsUSA, called the…

  15. Student Achievement and Attitude in a Satellite-Delivered High School Science Course.

    ERIC Educational Resources Information Center

    Martin, Elaine D.; Rainey, Larry

    1993-01-01

    Discusses results of a study of high school students that was conducted to determine, through measures of student achievement, the educational effectiveness of interactive satellite delivery compared with traditional classroom instruction in anatomy and physiology and to compare the attitudes toward anatomy and physiology of distance students and…

  16. Development of a percutaneous penetration predictive model by SR-FTIR.

    PubMed

    Jungman, E; Laugel, C; Rutledge, D N; Dumas, P; Baillet-Guffroy, A

    2013-01-30

    This work focused on developing a new evaluation criterion of percutaneous penetration, in complement to Log Pow and MW and based on high spatial resolution Fourier transformed infrared (FTIR) microspectroscopy with a synchrotron source (SR-FTIR). Classic Franz cell experiments were run and after 22 h molecule distribution in skin was determined either by HPLC or by SR-FTIR. HPLC data served as reference. HPLC and SR-FTIR results were compared and a new predictive criterion based from SR-FTIR results, named S(index), was determined using a multi-block data analysis technique (ComDim). A predictive cartography of the distribution of molecules in the skin was built and compared to OECD predictive cartography. This new criterion S(index) and the cartography using SR-FTIR/HPLC results provides relevant information for risk analysis regarding prediction of percutaneous penetration and could be used to build a new mathematical model. Copyright © 2012 Elsevier B.V. All rights reserved.

  17. Flow interference in a variable porosity trisonic wind tunnel.

    NASA Technical Reports Server (NTRS)

    Davis, J. W.; Graham, R. F.

    1972-01-01

    Pressure data from a 20-degree cone-cylinder in a variable porosity wind tunnel for the Mach range 0.2 to 5.0 are compared to an interference free standard in order to determine wall interference effects. Four 20-degree cone-cylinder models representing an approximate range of percent blockage from one to six were compared to curve-fits of the interference free standard at each Mach number and errors determined at each pressure tap location. The average of the absolute values of the percent error over the length of the model was determined and used as the criterion for evaluating model blockage interference effects. The results are presented in the form of the percent error as a function of model blockage and Mach number.

  18. The Determination of the Percent of Oxygen in Air Using a Gas Pressure Sensor

    ERIC Educational Resources Information Center

    Gordon, James; Chancey, Katherine

    2005-01-01

    The experiment of determination of the percent of oxygen in air is performed in a general chemistry laboratory in which students compare the results calculated from the pressure measurements obtained with the calculator-based systems to those obtained in a water-measurement method. This experiment allows students to explore a fundamental reaction…

  19. The Supply and Demand of Technology and Engineering Teachers in the United States: Who Knows?

    ERIC Educational Resources Information Center

    Moye, Johnny J.

    2017-01-01

    The purpose of this study was to determine the supply and demand of technology and engineering teachers in the United States. Once gathered, the resulting data (that was available) was compared to previous studies to determine trends. The researcher reviewed the 2010-11 through 2015-16 Technology & Engineering Teacher Education Directories. To…

  20. Flight-determined aerodynamic derivatives of the AD-1 oblique-wing research airplane

    NASA Technical Reports Server (NTRS)

    Sim, A. G.; Curry, R. E.

    1984-01-01

    The AD-1 is a variable-sweep oblique-wing research airplane that exhibits unconventional stability and control characteristics. In this report, flight-determined and predicted stability and control derivatives for the AD-1 airplane are compared. The predictions are based on both wind tunnel and computational results. A final best estimate of derivatives is presented.

  1. Leadership Characteristics for Health Care Managers: Perspectives of Chief Executive Officers in US Hospitals.

    PubMed

    Collins, Sandra K; McKinnies, Richard; Collins, Kevin S

    2015-01-01

    A study was conducted to determine the perceptions of chief executive officers in US hospitals regarding the most important characteristics aspiring health care executives should possess. The results of this 2012 study were compared with a previous study conducted in 2007 to determine if the perceptions had changed over time.

  2. A comparative study of two methods for the orientation of the occlusal plane and the determination of the vertical dimension of occlusion in edentulous patients.

    PubMed

    Koller, M M; Merlini, L; Spandre, G; Palla, S

    1992-07-01

    The aim of this study was to compare two methods used to orientate the occlusal plane (OP) and to determine the vertical dimension of occlusion (VDO). In method A the VDO was established by means of the rest position, the minimal speaking distance, and the patient's profile. Method B used a newly developed registration pin assembly. The VDO was registered using a silicone occlusion rim and the swallowing technique. The results were compared to the values of the new dentures. Three standardized lateral radiographs were taken at the VDO obtained with methods A, B, and at that of the final dentures. On each radiograph the orientation of the OP to the Camper plane and the VDO were measured by two investigators independently. The results indicated no statistically significant differences between the mean VDO with method A and B compared with the new dentures (P greater than 0.05). With both methods it was not possible to orientate the OP parallel to the Camper plane. None of the occlusal planes of the new dentures were parallel either. Their OP diverged on average by 7 degrees dorso-caudally. The time spent with method B to orient the OP and to determine the VDO was significantly lower than with method A (17-50 min).

  3. The role of sample preparation in interpretation of trace element concentration variability in moss bioindication studies

    USGS Publications Warehouse

    Migaszewski, Z.M.; Lamothe, P.J.; Crock, J.G.; Galuszka, A.; Dolegowska, S.

    2011-01-01

    Trace element concentrations in plant bioindicators are often determined to assess the quality of the environment. Instrumental methods used for trace element determination require digestion of samples. There are different methods of sample preparation for trace element analysis, and the selection of the best method should be fitted for the purpose of a study. Our hypothesis is that the method of sample preparation is important for interpretation of the results. Here we compare the results of 36 element determinations performed by ICP-MS on ashed and on acid-digested (HNO3, H2O2) samples of two moss species (Hylocomium splendens and Pleurozium schreberi) collected in Alaska and in south-central Poland. We found that dry ashing of the moss samples prior to analysis resulted in considerably lower detection limits of all the elements examined. We also show that this sample preparation technique facilitated the determination of interregional and interspecies differences in the chemistry of trace elements. Compared to the Polish mosses, the Alaskan mosses displayed more positive correlations of the major rock-forming elements with ash content, reflecting those elements' geogenic origin. Of the two moss species, P. schreberi from both Alaska and Poland was also highlighted by a larger number of positive element pair correlations. The cluster analysis suggests that the more uniform element distribution pattern of the Polish mosses primarily reflects regional air pollution sources. Our study has shown that the method of sample preparation is an important factor in statistical interpretation of the results of trace element determinations. ?? 2010 Springer-Verlag.

  4. Effects of biodiesel on emissions of a bus diesel engine.

    PubMed

    Kegl, Breda

    2008-03-01

    This paper discusses the influence of biodiesel on the injection, spray, and engine characteristics with the aim to reduce harmful emissions. The considered engine is a bus diesel engine with injection M system. The injection, fuel spray, and engine characteristics, obtained with biodiesel, are compared to those obtained with mineral diesel (D2) under various operating regimes. The considered fuel is neat biodiesel from rapeseed oil. Its density, viscosity, surface tension, and sound velocity are determined experimentally and compared to those of D2. The obtained results are used to analyze the most important injection, fuel spray, and engine characteristics. The injection characteristics are determined numerically under the operating regimes, corresponding to the 13 mode ESC test. The fuel spray is obtained experimentally under peak torque condition. Engine characteristics are determined experimentally under 13 mode ESC test conditions. The results indicate that, by using biodiesel, harmful emissions (NO(x), CO, smoke and HC) can be reduced to some extent by adjusting the injection pump timing properly.

  5. In vitro activity of doripenem and other carbapenems against contemporary Gram-negative pathogens isolated from hospitalised patients in the Asia-Pacific region: results of the COMPACT Asia-Pacific Study.

    PubMed

    Christiansen, K J; Ip, M; Ker, H B; Mendoza, M; Hsu, L; Kiratisin, P; Chongthaleong, A; Redjeki, I S; Quintana, A; Flamm, R; Garcia, J; Cassettari, M; Cooper, D; Okolo, P; Morrissey, I

    2010-12-01

    The Comparative Activity of Carbapenems Testing (COMPACT) Study was designed to determine the in vitro potency of doripenem compared with imipenem and meropenem against a large number of contemporary Gram-negative pathogens from more than 100 centres across Europe and the Asia-Pacific region and to assess the reliability of Etest methodology for doripenem minimum inhibitory concentration (MIC) determination against these pathogens. Data from eight countries within the Asia-Pacific region, which collected 1612 bacterial isolates, are presented here. Etest methodology was found to be a reliable method for MIC determination. Doripenem showed in vitro activity similar to or better than meropenem and at least four-fold better than imipenem against Enterobacteriaceae. Against Pseudomonas aeruginosa, doripenem was also the most active of the three carbapenems in vitro. However, in vitro results do not necessarily correlate with clinical outcome. Copyright © 2010 Elsevier B.V. and the International Society of Chemotherapy. All rights reserved.

  6. Observations of Omicron 1 Cygni (STFA 50AD)

    NASA Astrophysics Data System (ADS)

    Bidler, Jeff; Hagee, Joshua; McGuire, Paul; McGuire, Rosa; Montes, Leslie; Richardson, Nicole; Rodriguez, Arturo; Brewer, Mark

    2016-10-01

    In over 215 years, the star STFA 50AD located in the Cygnus constellation has only been analyzed about 35 times. A group of eight individuals from five affiliations participated in the third annual Apple Valley Double Star Workshop to measure the separations and position angles of a double star. During this workshop, data from several astronomical identifiers was used to compare the data collected. The main apparatus used was an 8-inch telescope. An astrometric eyepiece and a stopwatch were used. The scale constant 9.9 arc seconds per division mark, separations 340.9 arc seconds, and position angles 324.1 degrees were determined by the telescope-eyepiece combination. The plate scale 1.01 arc seconds per pixel, separation 337.1 arc seconds, and position angle 321.3 degrees were determined by using the Digitized Sky Survey and Astrometrica. The results obtained were compared to previous observations listed in the Washington Double Star Catalog. After rigorous calculations and teamwork, it was concluded that the 2008 results were determined to be an outlier.

  7. Random vibration (stress screening) of printed wiring assemblies

    NASA Technical Reports Server (NTRS)

    Bastien, Gilbert J.

    1988-01-01

    The results of a random vibration test screening (RVSS) study of the determination of the upper and lower vibration limits on printed wiring assemblies (PWA) are summarized. The study results are intended to serve as a guide for engineers and designers who make decisions on PWA features that need to withstand the stresses of dynamic testing and screening. The maximum allowable PWA deflection, G levels, and PSD levels are compared to the expected or actual levels to determine if deleterious effects will occur.

  8. Exit Presentation: Infrared Thermography on Graphite/Epoxy

    NASA Technical Reports Server (NTRS)

    Comeaux, Kayla

    2010-01-01

    This slide presentation reports on the internship project that was accomplished during the summer of 2010. The objectives of the project were to: (1) Simulate Flash Thermography on Graphite/Epoxy Flat Bottom hole Specimen and thin void specimens, (2) Obtain Flash Thermography data on Graphite/Epoxy flat bottom hole specimens, (3) Compare experimental results with simulation results, Compare Flat Bottom Hole Simulation with Thin Void Simulation to create a graph to determine size of IR Thermography detected defects

  9. NASTRAN Analysis Comparison to Shock Tube Tests Used to Simulate Nuclear Overpressures

    NASA Technical Reports Server (NTRS)

    Wheless, T. K.

    1985-01-01

    This report presents a study of the effectiveness of the NASTRAN computer code for predicting structural response to nuclear blast overpressures. NASTRAN's effectiveness is determined by comparing results against shock tube tests used to simulate nuclear overpressures. Seven panels of various configurations are compared in this study. Panel deflections are the criteria used to measure NASTRAN's effectiveness. This study is a result of needed improvements in the survivability/vulnerability analyses subjected to nuclear blast.

  10. Research to improve the accuracy of determining the stroke volume of an artificial ventricle using the wavelet transform

    NASA Astrophysics Data System (ADS)

    Grad, Leszek; Murawski, Krzysztof; Sulej, Wojciech

    2017-08-01

    In the article we presented results obtained during research, which are the continuation of work on the use of artificial neural networks to determine the relationship between the view of the membrane and the stroke volume of the blood chamber of the mechanical prosthetic heart. The purpose of the research was to increase the accuracy of determining the blood chamber volume. Therefore, the study was focused on the technique of the features that the image extraction gives. During research we used the wavelet transform. The achieved results were compared to the results obtained by other previous methods. Tests were conducted on the same mechanical prosthetic heart model used in previous experiments.

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Asadi, Somayeh; Masoudi, Seyed Farhad, E-mail: masoudi@kntu.ac.ir; Shahriari, Majid

    In ophthalmic brachytherapy dosimetry, it is common to consider the water phantom as human eye anatomy. However, for better clinical analysis, there is a need for the dose determination in different parts of the eye. In this work, a full human eye is simulated with MCNP-4C code by considering all parts of the eye, i.e., the lens, cornea, retina, choroid, sclera, anterior chamber, optic nerve, and bulk of the eye comprising vitreous body and tumor. The average dose in different parts of this full model of the human eye is determined and the results are compared with the dose calculatedmore » in water phantom. The central axes depth dose and the dose in whole of the tumor for these 2 simulated eye models are calculated as well, and the results are compared.« less

  12. Finite Element Analysis of Simple Rectangular Microstrip Sensor for Determination Moisture Content of Hevea Rubber Latex

    NASA Astrophysics Data System (ADS)

    Yahaya, NZ; Ramli, MR; Razak, NNANA; Abbas, Z.

    2018-04-01

    The Finite Element Method, FEM has been successfully used to model a simple rectangular microstrip sensor to determine the moisture content of Hevea rubber latex. The FEM simulation of sensor and samples was implemented by using COMSOL Multiphysics software. The simulation includes the calculation of magnitude and phase of reflection coefficient and was compared to analytical method. The results show a good agreement in finding the magnitude and phase of reflection coefficient when compared with analytical results. Field distributions of both the unloaded sensor as well as the sensor loaded with different percentages of moisture content were visualized using FEM in conjunction with COMSOL software. The higher the amount of moisture content in the sample the more the electric loops were observed.

  13. Broadening of the infrared absorption lines at reduced temperatures. II - Carbon monoxide in an atmosphere of carbon dioxide.

    NASA Technical Reports Server (NTRS)

    Tubbs, L. D.; Williams, D.

    1972-01-01

    The strengths of the rotational lines in the R branch of the CO fundamental have been determined at temperatures of 298, 202, and 132 K by means of a high-resolution spectrograph. The results can be used to determine line strengths at other temperatures by means of the Herman-Wallis relation or by considerations of the populations of the rotational levels in the ground vibrational state. Parameters describing the self-broadening and carbon dioxide broadening of CO lines have been determined at 298 and 202 K. The results are compared with other recent experimental and theoretical studies.

  14. [Determination of eight trace elements in the Swertia davidii Franch by flame atomic absorption spectrometry].

    PubMed

    Li, Tao; Wang, Yuan-zhong; Yu, Hon; Cao, Yu-juan; Zhang, Jing-jing; Liu, Qin

    2007-12-01

    The effects of different sample digestives on the determination of Swertia davidii Franch are compared. Eight trace elements in the Swertia davidii Franch were determined by flame atomic absorption spectrometry. The result shows that the RSD and recovery are better if the Swertia davidii Franch was digested with HNO3-HClO4 (5 : 1) mixed acid. The experimental results show that the detection limits were all smaller than 0.097 microg x mL(-1), the RSDs (n=8) all smaller than 2.34%, and the addition standard recovery (ASR) (n=8) was 89.32%-106.65% for all the elements.

  15. Improved Correction of Misclassification Bias With Bootstrap Imputation.

    PubMed

    van Walraven, Carl

    2018-07-01

    Diagnostic codes used in administrative database research can create bias due to misclassification. Quantitative bias analysis (QBA) can correct for this bias, requires only code sensitivity and specificity, but may return invalid results. Bootstrap imputation (BI) can also address misclassification bias but traditionally requires multivariate models to accurately estimate disease probability. This study compared misclassification bias correction using QBA and BI. Serum creatinine measures were used to determine severe renal failure status in 100,000 hospitalized patients. Prevalence of severe renal failure in 86 patient strata and its association with 43 covariates was determined and compared with results in which renal failure status was determined using diagnostic codes (sensitivity 71.3%, specificity 96.2%). Differences in results (misclassification bias) were then corrected with QBA or BI (using progressively more complex methods to estimate disease probability). In total, 7.4% of patients had severe renal failure. Imputing disease status with diagnostic codes exaggerated prevalence estimates [median relative change (range), 16.6% (0.8%-74.5%)] and its association with covariates [median (range) exponentiated absolute parameter estimate difference, 1.16 (1.01-2.04)]. QBA produced invalid results 9.3% of the time and increased bias in estimates of both disease prevalence and covariate associations. BI decreased misclassification bias with increasingly accurate disease probability estimates. QBA can produce invalid results and increase misclassification bias. BI avoids invalid results and can importantly decrease misclassification bias when accurate disease probability estimates are used.

  16. Determination of post-shakedown quantities of a pipe bend via the simplified theory of plastic zones compared with load history dependent incremental analysis

    NASA Astrophysics Data System (ADS)

    Vollrath, Bastian; Hübel, Hartwig

    2018-01-01

    The Simplified Theory of Plastic Zones (STPZ) may be used to determine post-shakedown quantities such as strain ranges and accumulated strains at plastic or elastic shakedown. The principles of the method are summarized. Its practical applicability is shown by the example of a pipe bend subjected to constant internal pressure along with cyclic in-plane bending or/and cyclic radial temperature gradient. The results are compared with incremental analyses performed step-by-step throughout the entire load history until the state of plastic shakedown is achieved.

  17. Residual stress in glass: indentation crack and fractography approaches

    PubMed Central

    Anunmana, Chuchai; Anusavice, Kenneth J.; Mecholsky, John J.

    2009-01-01

    Objective To test the hypothesis that the indentation crack technique can determine surface residual stresses that are not statistically significantly different from those determined from the analytical procedure using surface cracks, the four-point flexure test, and fracture surface analysis. Methods Soda-lime-silica glass bar specimens (4 mm × 2.3 mm × 28 mm) were prepared and annealed at 650 °C for 30 min before testing. The fracture toughness values of the glass bars were determined from 12 specimens based on induced surface cracks, four-point flexure, and fractographic analysis. To determine the residual stress from the indentation technique, 18 specimens were indented under 19.6 N load using a Vickers microhardness indenter. Crack lengths were measured within 1 min and 24 h after indentation, and the measured crack lengths were compared with the mean crack lengths of annealed specimens. Residual stress was calculated from an equation developed for the indentation technique. All specimens were fractured in a four-point flexure fixture and the residual stress was calculated from the strength and measured crack sizes on the fracture surfaces. Results The results show that there was no significant difference between the residual stresses calculated from the two techniques. However, the differences in mean residual stresses calculated within 1 min compared with those calculated after 24 h were statistically significant (p=0.003). Significance This study compared the indentation technique with the fractographic analysis method for determining the residual stress in the surface of soda-lime silica glass. The indentation method may be useful for estimating residual stress in glass. PMID:19671475

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kurnik, Charles W.; Boyd, Brian; Stoughton, Kate M.

    This measurement and verification (M and V) protocol provides procedures for energy service companies (ESCOs) and water efficiency service companies (WESCOs) to determine water savings resulting from water conservation measures (WCMs) in energy performance contracts associated with cooling tower efficiency projects. The water savings are determined by comparing the baseline water use to the water use after the WCM has been implemented. This protocol outlines the basic structure of the M and V plan, and details the procedures to use to determine water savings.

  19. Antioxidant and Antiplasmodial Activities of Bergenin and 11-O-Galloylbergenin Isolated from Mallotus philippensis

    PubMed Central

    Khan, Hamayun; Amin, Hazrat; Ullah, Asad; Saba, Sumbal; Rafique, Jamal; Khan, Khalid; Ahmad, Nasir; Badshah, Syed Lal

    2016-01-01

    Two important biologically active compounds were isolated from Mallotus philippensis. The isolated compounds were characterized using spectroanalytical techniques and found to be bergenin (1) and 11-O-galloylbergenin (2). The in vitro antioxidant and antiplasmodial activities of the isolated compounds were determined. For the antioxidant potential, three standard analytical protocols, namely, DPPH radical scavenging activity (RSA), reducing power assay (RPA), and total antioxidant capacity (TAC) assay, were adopted. The results showed that compound 2 was found to be more potent antioxidant as compared to 1. Fascinatingly, compound 2 displayed better EC50 results as compared to α-tocopherol while being comparable with ascorbic acid. The antiplasmodial assay data showed that both the compound exhibited good activity against chloroquine sensitive strain of Plasmodium falciparum (D10) and IC50 values were found to be less than 8 μM. The in silico molecular docking analyses were also performed for the determination of binding affinity of the isolated compounds using P. falciparum proteins PfLDH and Pfg27. The results showed that compound 2 has high docking score and binding affinity to both protein receptors as compared to compound 1. The demonstrated biological potentials declared that compound 2 could be the better natural antioxidant and antiplasmodial candidate. PMID:26998192

  20. Determining the biomass fraction of mixed waste fuels: A comparison of existing industry and {sup 14}C-based methodologies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Muir, G.K.P., E-mail: Graham.Muir@glasgow.ac.uk; Hayward, S.; Tripney, B.G.

    2015-01-15

    Highlights: • Compares industry standard and {sup 14}C methods for determining bioenergy content of MSW. • Differences quantified through study at an operational energy from waste plant. • Manual sort and selective dissolution are unreliable measures of feedstock bioenergy. • {sup 14}C methods (esp. AMS) improve precision and reliability of bioenergy determination. • Implications for electricity generators and regulators for award of bio-incentives. - Abstract: {sup 14}C analysis of flue gas by accelerator mass spectrometry (AMS) and liquid scintillation counting (LSC) were used to determine the biomass fraction of mixed waste at an operational energy-from-waste (EfW) plant. Results were convertedmore » to bioenergy (% total) using mathematical algorithms and assessed against existing industry methodologies which involve manual sorting and selective dissolution (SD) of feedstock. Simultaneous determinations using flue gas showed excellent agreement: 44.8 ± 2.7% for AMS and 44.6 ± 12.3% for LSC. Comparable bioenergy results were obtained using a feedstock manual sort procedure (41.4%), whilst a procedure based on selective dissolution of representative waste material is reported as 75.5% (no errors quoted). {sup 14}C techniques present significant advantages in data acquisition, precision and reliability for both electricity generator and industry regulator.« less

  1. Optical waveguide lightmode spectroscopy technique-based immunosensor development for aflatoxin B1 determination in spice paprika samples.

    PubMed

    Majer-Baranyi, Krisztina; Zalán, Zsolt; Mörtl, Mária; Juracsek, Judit; Szendrő, István; Székács, András; Adányi, Nóra

    2016-11-15

    Optical waveguide lightmode spectroscopy (OWLS) technique has been applied to label-free detection of aflatoxin B1 in a competitive immunoassay format, with the aim to compare the analytical goodness of the developed OWLS immunosenor with HPLC and enzyme-linked immunosorbent assay (ELISA) methods for the detection of aflatoxin in spice paprika matrix. We have also assessed applicability of the QuEChERS method prior to ELISA measurements, and the results were compared to those obtained by traditional solvent extraction followed by immunoaffinity clean-up. The AFB1 content of sixty commercial spice paprika samples from different countries were measured with the developed and optimized OWLS immunosensor. Comparing the results from the indirect immunosensor to that obtained by HPLC or ELISA provided excellent correlation (with regression coefficients above 0.94) indicating that the competitive OWLS immunosensor has a potential for quick determination of aflatoxin B1 in paprika samples. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. A comparative study of neutron activation analysis and proton-induced X-ray emission analysis for the determination of heavy metals in estuarine sediments

    NASA Astrophysics Data System (ADS)

    Randle, K.; Al-Jundi, J.; Mamas, C. J. V.; Sokhi, R. S.; Earwaker, L. G.

    1993-06-01

    Our work on heavy metals in the estuarine environment has involved the use of two multielement techniques: neutron activation analysis (NAA) and proton-induced X-ray emission (PIXE) analysis. As PIXE is essentially a surface analytical technique problems may arise due to sample inhomogeneity and surface roughness. In order to assess the contribution of these effects we have compared the results from PIXE analysis with those from a technique which analyzes a larger bulk sample rather than just the surface. An obvious method was NAA. A series of sediment samples containing particles of variable diameter were compared. Pellets containing a few mg of sediment were prepared from each sample and analyzed by the PIXE technique using both an absolute and a comparitive method. For INAA the rest of the sample was then irradiated with thermal neutrons and element concentrations determined from analyses of the subsequent gamma-ray spectrum. Results from the two methods are discussed.

  3. Set Shifting Among Adolescents with Anorexia Nervosa

    PubMed Central

    Fitzpatrick, Kathleen Kara; Darcy, Alison; Colborn, Danielle; Gudorf, Caroline; Lock, James

    2012-01-01

    Objective Set shifting difficulties are documented for adults with anorexia nervosa (AN). However, AN typically onsets in adolescents and it is unclear if set-shifting difficulties are a result of chronic AN or present earlier in its course. This study examined whether adolescents with short duration AN demonstrated set shifting difficulties compared to healthy controls (HC). Method Data on set shifting collected from the Delis-Kaplan Executive Functioning System (DKEFS) and Wisconsin Card Sort Task (WCST) as well as eating psychopathology were collected from 32 adolescent inpatients with AN and compared to those from 22 HCs. Results There were no differences in set-shifting in adolescents with AN compared to HCs on most measures. Conclusion The findings suggest that set-shifting difficulties in AN may be a consequence of AN. Future studies should explore set-shifting difficulties in a larger sample of adolescents with the AN to determine if there is sub-set of adolescents with these difficulties and determine any relationship of set-shifting to the development of a chronic from of AN. PMID:22692985

  4. Abort Region Determinator (ARD) module feasibility report. Mission planning, mission analysis and software formulation

    NASA Technical Reports Server (NTRS)

    Draeger, B. G.; Joyner, J. A.

    1976-01-01

    A detailed performance evaluation of the Abort Region Determinator (ARD) module design was provided in support of OFT-1 ascent and OFT-1 intact launch aborts. The evaluation method used compared ARD results against results obtained using the full-up Space Vehicle Dynamic Simulations program under the same conditions. Results were presented for each of the three major ARD math models: (1) the ascent numerical integrator; (2) the mass model, and (3) the second stage predictor as well as the total ARD module. These results demonstrate that the baselined ARD module meets all design objectives for mission control center orbital flight test launch/abort support.

  5. Evaluation of TDRSS-user orbit determination accuracy using batch least-squares and sequential methods

    NASA Technical Reports Server (NTRS)

    Oza, D. H.; Jones, T. L.; Hodjatzadeh, M.; Samii, M. V.; Doll, C. E.; Hart, R. C.; Mistretta, G. D.

    1991-01-01

    The development of the Real-Time Orbit Determination/Enhanced (RTOD/E) system as a prototype system for sequential orbit determination on a Disk Operating System (DOS) based Personal Computer (PC) is addressed. The results of a study to compare the orbit determination accuracy of a Tracking and Data Relay Satellite System (TDRSS) user spacecraft obtained using RTOD/E with the accuracy of an established batch least squares system, the Goddard Trajectory Determination System (GTDS), is addressed. Independent assessments were made to examine the consistencies of results obtained by the batch and sequential methods. Comparisons were made between the forward filtered RTOD/E orbit solutions and definitive GTDS orbit solutions for the Earth Radiation Budget Satellite (ERBS); the maximum solution differences were less than 25 m after the filter had reached steady state.

  6. Evaluation of direct saponification method for determination of cholesterol in meats.

    PubMed

    Adams, M L; Sullivan, D M; Smith, R L; Richter, E F

    1986-01-01

    A gas chromatographic (GC) method has been developed for determination of cholesterol in meats. The method involves ethanolic KOH saponification of the sample material, homogeneous-phase toluene extraction of the unsaponifiables, derivatization of cholesterol to its trimethylsilylether, and quantitation by GC-flame ionization detection using 5-alpha-cholestane as internal standard. This direct saponification method is compared with the current AOAC official method for determination of cholesterol in 20 different meat products. The direct saponification method eliminates the need for initial lipid extraction, thus offering a 30% savings in labor, and requires fewer solvents than the AOAC method. It produced comparable or slightly higher cholesterol results than the AOAC method in all meat samples examined. Precision, determined by assaying a turkey meat sample 16 times over 4 days, was excellent (CV = 1.74%). Average recovery of cholesterol added to meat samples was 99.8%.

  7. Direct determination of total sulfur in wine using a continuum-source atomic-absorption spectrometer and an air-acetylene flame.

    PubMed

    Huang, Mao Dong; Becker-Ross, Helmut; Florek, Stefan; Heitmann, Uwe; Okruss, Michael

    2005-08-01

    Determination of sulfur in wine is an important analytical task, particularly with regard to food safety legislation, wine trade, and oenology. Hitherto existing methods for sulfur determination all have specific drawbacks, for example high cost and time consumption, poor precision or selectivity, or matrix effects. In this paper a new method, with low running costs, is introduced for direct, reliable, rapid, and accurate determination of the total sulfur content of wine samples. The method is based on measurement of the molecular absorption of carbon monosulfide (CS) in an ordinary air-acetylene flame by using a high-resolution continuum-source atomic-absorption spectrometer including a novel high-intensity short-arc xenon lamp. First results for total sulfur concentrations in different wine samples were compared with data from comparative ICP-MS measurements. Very good agreement within a few percent was obtained.

  8. Similarity estimation for reference image retrieval in mammograms using convolutional neural network

    NASA Astrophysics Data System (ADS)

    Muramatsu, Chisako; Higuchi, Shunichi; Morita, Takako; Oiwa, Mikinao; Fujita, Hiroshi

    2018-02-01

    Periodic breast cancer screening with mammography is considered effective in decreasing breast cancer mortality. For screening programs to be successful, an intelligent image analytic system may support radiologists' efficient image interpretation. In our previous studies, we have investigated image retrieval schemes for diagnostic references of breast lesions on mammograms and ultrasound images. Using a machine learning method, reliable similarity measures that agree with radiologists' similarity were determined and relevant images could be retrieved. However, our previous method includes a feature extraction step, in which hand crafted features were determined based on manual outlines of the masses. Obtaining the manual outlines of masses is not practical in clinical practice and such data would be operator-dependent. In this study, we investigated a similarity estimation scheme using a convolutional neural network (CNN) to skip such procedure and to determine data-driven similarity scores. By using CNN as feature extractor, in which extracted features were employed in determination of similarity measures with a conventional 3-layered neural network, the determined similarity measures were correlated well with the subjective ratings and the precision of retrieving diagnostically relevant images was comparable with that of the conventional method using handcrafted features. By using CNN for determination of similarity measure directly, the result was also comparable. By optimizing the network parameters, results may be further improved. The proposed method has a potential usefulness in determination of similarity measure without precise lesion outlines for retrieval of similar mass images on mammograms.

  9. Title I Comparability: A Preliminary Evaluation.

    ERIC Educational Resources Information Center

    Lawyers' Committee for Civil Rights Under Law, Washington, DC.

    This publication reports the results of a study of comparability data submitted by 80 of the nation's largest school districts. The study sought to determine the degree of school district compliance with USOE regulations implementing Title I of the Elementary and Secondary Education Act of 1965. Of the 80 schools, the study found that (1) 29.38…

  10. A Study Comparing Fifth Grade Student Achievement in Mathematics in Departmentalized and Non-Departmentalized Settings

    ERIC Educational Resources Information Center

    Nelson, Karen Ann

    2014-01-01

    The purpose of this quantitative, causal-comparative study was to examine the application of the teaching and learning theory of social constructivism in order to determine if mathematics instruction provided in a departmentalized classroom setting at the fifth grade level resulted in a statistically significant difference in student achievement…

  11. Occurrence of Conotruncal Heart Birth Defects in Texas: A Comparison of Urban/Rural Classifications

    ERIC Educational Resources Information Center

    Langlois, Peter H.; Jandle, Leigh; Scheuerle, Angela; Horel, Scott A.; Carozza, Susan E.

    2010-01-01

    Purpose: (1) Determine if there is an association between 3 conotruncal heart birth defects and urban/rural residence of mother. (2) Compare results using different methods of measuring urban/rural status. Methods: Data were taken from the Texas Birth Defects Registry, 1999-2003. Poisson regression was used to compare crude and adjusted birth…

  12. Brief Strategic Family Therapy versus Treatment as Usual: Results of a Multisite Randomized Trial for Substance Using Adolescents

    ERIC Educational Resources Information Center

    Robbins, Michael S.; Feaster, Daniel J.; Horigian, Viviana E.; Rohrbaugh, Michael; Shoham, Varda; Bachrach, Ken; Miller, Michael; Burlew, Kathleen A.; Hodgkins, Candy; Carrion, Ibis; Vandermark, Nancy; Schindler, Eric; Werstlein, Robert; Szapocznik, Jose

    2011-01-01

    Objective: To determine the effectiveness of brief strategic family therapy (BSFT; an evidence-based family therapy) compared to treatment as usual (TAU) as provided in community-based adolescent outpatient drug abuse programs. Method: A randomized effectiveness trial in the National Drug Abuse Treatment Clinical Trials Network compared BSFT to…

  13. A simplex method for the orbit determination of maneuvering satellites

    NASA Astrophysics Data System (ADS)

    Chen, JianRong; Li, JunFeng; Wang, XiJing; Zhu, Jun; Wang, DanNa

    2018-02-01

    A simplex method of orbit determination (SMOD) is presented to solve the problem of orbit determination for maneuvering satellites subject to small and continuous thrust. The objective function is established as the sum of the nth powers of the observation errors based on global positioning satellite (GPS) data. The convergence behavior of the proposed method is analyzed using a range of initial orbital parameter errors and n values to ensure the rapid and accurate convergence of the SMOD. For an uncontrolled satellite, the orbit obtained by the SMOD provides a position error compared with GPS data that is commensurate with that obtained by the least squares technique. For low Earth orbit satellite control, the precision of the acceleration produced by a small pulse thrust is less than 0.1% compared with the calibrated value. The orbit obtained by the SMOD is also compared with weak GPS data for a geostationary Earth orbit satellite over several days. The results show that the position accuracy is within 12.0 m. The working efficiency of the electric propulsion is about 67% compared with the designed value. The analyses provide the guidance for subsequent satellite control. The method is suitable for orbit determination of maneuvering satellites subject to small and continuous thrust.

  14. Two Methods of Determining Total Phenolic Content of Foods and Juices in a General, Organic, and Biological (GOB) Chemistry Lab

    ERIC Educational Resources Information Center

    Shaver, Lee Alan; Leung, Sam H.; Puderbaugh, Amy; Angel, Stephen A.

    2011-01-01

    The determination of total phenolics in foods and fruit juices was used successfully as a laboratory experiment in our undergraduate general, organic, and biological (GOB) chemistry course. Two different colorimetric methods were used over three years and comparative student results indicate that a ferrous ammonium sulfate (FAS) indicator…

  15. Simultaneous spectrophotometric determination of salbutamol and bromhexine in tablets.

    PubMed

    Habib, I H I; Hassouna, M E M; Zaki, G A

    2005-03-01

    Typical anti-mucolytic drugs called salbutamol hydrochloride and bromhexine sulfate encountered in tablets were determined simultaneously either by using linear regression at zero-crossing wavelengths of the first derivation of UV-spectra or by application of multiple linear partial least squares regression method. The results obtained by the two proposed mathematical methods were compared with those obtained by the HPLC technique.

  16. Determining Science Teacher Candidates' Academic Knowledge and Misconceptions about Electric Current

    ERIC Educational Resources Information Center

    Sert Çibik, Ayse

    2017-01-01

    The aim of this study is two-fold. Its first aim is to determine science teacher candidates' knowledge (academic success) and misconceptions about electric current and its second aim is to compare these results across participants' year of study and gender. A total of 132 teacher candidates studying in their 2nd, 3rd, and 4th years in Gazi…

  17. New rapid method for determining edgewise compressive strength of corrugated fiberboard

    Treesearch

    John W. Koning

    1986-01-01

    The objective of this study was to determine if corrugated fiberboard specimens that had been necked down with a common router would yield acceptable edgewise compressive strength values. Tests were conducted on specimens prepared using a circular saw and router, and the results were compared with those obtained on specimens prepared according to TAPPI Test Method T...

  18. Determination of quaternary ammonium compounds by potentiometric titration with an ionic surfactant electrode: single-laboratory validation.

    PubMed

    Price, Randi; Wan, Ping

    2010-01-01

    A potentiometric titration for determining the quaternary ammonium compounds (QAC) commonly found in antimicrobial products was validated by a single laboratory. Traditionally, QACs were determined by using a biphasic (chloroform and water) manual titration procedure. Because of safety considerations regarding chloroform, as well as the subjectivity of color indicator-based manual titration determinations, an automatic potentiometric titration procedure was tested with quaternary nitrogen product formulations. By using the Metrohm Titrando system coupled with an ionic surfactant electrode and an Ag/AgCl reference electrode, titrations were performed with various QAC-containing formulation products/matrixes; a standard sodium lauryl sulfate solution was used as the titrant. Results for the products tested are sufficiently reproducible and accurate for the purpose of regulatory product enforcement. The robustness of the method was measured by varying pH levels, as well as by comparing buffered versus unbuffered titration systems. A quantitation range of 1-1000 ppm quaternary nitrogen was established. Eight commercially available antimicrobial products covering a variety of matrixes were assayed; the results obtained were comparable to those obtained by the manual titration method. Recoveries of 94 to 104% were obtained for spiked samples.

  19. Determination of the fundamental properties of an M31 globular cluster from main-sequence photometry

    NASA Astrophysics Data System (ADS)

    Ma, Jun

    2013-02-01

    We determined the age of the M31 globular cluster B379 using isochrones of the Padova stellar evolutionary models. At the same time, the cluster's metal abundance, its distance modulus, and reddening value were also obtained. The results obtained in this paper are consistent with previous determinations, including the age. Brown et al. constrained the age of B379 by comparing its color-magnitude diagram with isochrones of the 2006 VandenBerg models. Therefore, this paper confirms the consistency of the age scale of B379 between the Padova isochrones and the 2006 VandenBerg isochrones. The results of B379 obtained in this paper are: metallicity [M/H] = log(Z/Z⊙) = -0.325 dex, age τ = 11.0 +/- 1.5 Gyr, reddening E(B - V) = 0.08 mag, and distance modulus (m - M)0 = 24.44 +/- 0.10 mag. Using the metallicity, the reddening value and the distance modulus obtained in this paper, we constrained the age of B379 by comparing its multicolor photometry with theoretical stellar population synthesis models. The age of B379 obtained is 10.6-0.76 +0.92 Gyr, which is in very good agreement with the determination from main-sequence photometry.

  20. Limb locomotion--speed distribution analysis as a new method for stance phase detection.

    PubMed

    Peham, C; Scheidl, M; Licka, T

    1999-10-01

    The stance phase is used for the determination of many parameters in motion analysis. In this technical note the authors present a new kinematical method for determination of stance phase. From the high-speed video data, the speed distribution of the horizontal motion of the distal limb is calculated. The speed with the maximum occurrence within the motion cycle defines the stance phase, and this speed is used as threshold for beginning and end of the stance phase. In seven horses the results obtained with the presented method were compared to synchronous stance phase determination using a force plate integrated in a hard track. The mean difference between the results was 10.8 ms, equalling 1.44% of mean stance phase duration. As a test, the presented method was applied to a horse trotting on the treadmill, and to a human walking on concrete. This article describes an easy and safe method for stance phase determination in continuous kinematic data and proves the reliability of the method by comparing it to kinetic stance phase detection. This method may be applied in several species and all gaits, on the treadmill and on firm ground.

  1. Simultaneous quantitative determination of paracetamol and tramadol in tablet formulation using UV spectrophotometry and chemometric methods

    NASA Astrophysics Data System (ADS)

    Glavanović, Siniša; Glavanović, Marija; Tomišić, Vladislav

    2016-03-01

    The UV spectrophotometric methods for simultaneous quantitative determination of paracetamol and tramadol in paracetamol-tramadol tablets were developed. The spectrophotometric data obtained were processed by means of partial least squares (PLS) and genetic algorithm coupled with PLS (GA-PLS) methods in order to determine the content of active substances in the tablets. The results gained by chemometric processing of the spectroscopic data were statistically compared with those obtained by means of validated ultra-high performance liquid chromatographic (UHPLC) method. The accuracy and precision of data obtained by the developed chemometric models were verified by analysing the synthetic mixture of drugs, and by calculating recovery as well as relative standard error (RSE). A statistically good agreement was found between the amounts of paracetamol determined using PLS and GA-PLS algorithms, and that obtained by UHPLC analysis, whereas for tramadol GA-PLS results were proven to be more reliable compared to those of PLS. The simplest and the most accurate and precise models were constructed by using the PLS method for paracetamol (mean recovery 99.5%, RSE 0.89%) and the GA-PLS method for tramadol (mean recovery 99.4%, RSE 1.69%).

  2. Excavatability and the effect of weathering degree on the excavatability of rock masses: An example from Eastern Turkey

    NASA Astrophysics Data System (ADS)

    Gurocak, Zulfu; Yalcin, Erkut

    2016-06-01

    In this study, the effect of the weathering degree on the excavatability of rock masses was investigated. The ophiolitic rock mass along the route of Komurhan Tunnel was chosen as the case study. Both laboratory and field studies were carried out for this purpose. In the first stage, the ophiolitic rock mass along the tunnel route was classified into three subzones according to the weathering degree and the ophiolitic rock masses of the each subzones were classified using the empirical excavatability classifications proposed by the different researchers. Furthermore, in-situ excavatability classes of rock masses in each zone were determined and the results were compared. The in-situ excavatability class of fresh (Zone-I) and slightly weathered (Zone-II) rock masses was determined as Blasting and that of moderately weathered (Zone-III) rock mass was determined as Very Hard/Very Difficult. As the obtained results were compared, it was found that the weathering degree has a significant effect on the excavatability and that it is more appropriate to prefer empirical classifications in the empirical determination of excavatability classes of rock masses having the same lithology by taking the weathering degree into account.

  3. Design of optimised backstepping controller for the synchronisation of chaotic Colpitts oscillator using shark smell algorithm

    NASA Astrophysics Data System (ADS)

    Fouladi, Ehsan; Mojallali, Hamed

    2018-01-01

    In this paper, an adaptive backstepping controller has been tuned to synchronise two chaotic Colpitts oscillators in a master-slave configuration. The parameters of the controller are determined using shark smell optimisation (SSO) algorithm. Numerical results are presented and compared with those of particle swarm optimisation (PSO) algorithm. Simulation results show better performance in terms of accuracy and convergence for the proposed optimised method compared to PSO optimised controller or any non-optimised backstepping controller.

  4. A Reliable, Feasible Method to Observe Neighborhoods at High Spatial Resolution

    PubMed Central

    Kepper, Maura M.; Sothern, Melinda S.; Theall, Katherine P.; Griffiths, Lauren A.; Scribner, Richard; Tseng, Tung-Sung; Schaettle, Paul; Cwik, Jessica M.; Felker-Kantor, Erica; Broyles, Stephanie T.

    2016-01-01

    Introduction Systematic social observation (SSO) methods traditionally measure neighborhoods at street level and have been performed reliably using virtual applications to increase feasibility. Research indicates that collection at even higher spatial resolution may better elucidate the health impact of neighborhood factors, but whether virtual applications can reliably capture social determinants of health at the smallest geographic resolution (parcel level) remains uncertain. This paper presents a novel, parcel-level SSO methodology and assesses whether this new method can be collected reliably using Google Street View and is feasible. Methods Multiple raters (N=5) observed 42 neighborhoods. In 2016, inter-rater reliability (observed agreement and kappa coefficient) was compared for four SSO methods: (1) street-level in person; (2) street-level virtual; (3) parcel-level in person; and (4) parcel-level virtual. Intra-rater reliability (observed agreement and kappa coefficient) was calculated to determine whether parcel-level methods produce results comparable to traditional street-level observation. Results Substantial levels of inter-rater agreement were documented across all four methods; all methods had >70% of items with at least substantial agreement. Only physical decay showed higher levels of agreement (83% of items with >75% agreement) for direct versus virtual rating source. Intra-rater agreement comparing street- versus parcel-level methods resulted in observed agreement >75% for all but one item (90%). Conclusions Results support the use of Google Street View as a reliable, feasible tool for performing SSO at the smallest geographic resolution. Validation of a new parcel-level method collected virtually may improve the assessment of social determinants contributing to disparities in health behaviors and outcomes. PMID:27989289

  5. Determining Reduced Order Models for Optimal Stochastic Reduced Order Models

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bonney, Matthew S.; Brake, Matthew R.W.

    2015-08-01

    The use of parameterized reduced order models(PROMs) within the stochastic reduced order model (SROM) framework is a logical progression for both methods. In this report, five different parameterized reduced order models are selected and critiqued against the other models along with truth model for the example of the Brake-Reuss beam. The models are: a Taylor series using finite difference, a proper orthogonal decomposition of the the output, a Craig-Bampton representation of the model, a method that uses Hyper-Dual numbers to determine the sensitivities, and a Meta-Model method that uses the Hyper-Dual results and constructs a polynomial curve to better representmore » the output data. The methods are compared against a parameter sweep and a distribution propagation where the first four statistical moments are used as a comparison. Each method produces very accurate results with the Craig-Bampton reduction having the least accurate results. The models are also compared based on time requirements for the evaluation of each model where the Meta- Model requires the least amount of time for computation by a significant amount. Each of the five models provided accurate results in a reasonable time frame. The determination of which model to use is dependent on the availability of the high-fidelity model and how many evaluations can be performed. Analysis of the output distribution is examined by using a large Monte-Carlo simulation along with a reduced simulation using Latin Hypercube and the stochastic reduced order model sampling technique. Both techniques produced accurate results. The stochastic reduced order modeling technique produced less error when compared to an exhaustive sampling for the majority of methods.« less

  6. Optimization of digital image processing to determine quantum dots' height and density from atomic force microscopy.

    PubMed

    Ruiz, J E; Paciornik, S; Pinto, L D; Ptak, F; Pires, M P; Souza, P L

    2018-01-01

    An optimized method of digital image processing to interpret quantum dots' height measurements obtained by atomic force microscopy is presented. The method was developed by combining well-known digital image processing techniques and particle recognition algorithms. The properties of quantum dot structures strongly depend on dots' height, among other features. Determination of their height is sensitive to small variations in their digital image processing parameters, which can generate misleading results. Comparing the results obtained with two image processing techniques - a conventional method and the new method proposed herein - with the data obtained by determining the height of quantum dots one by one within a fixed area, showed that the optimized method leads to more accurate results. Moreover, the log-normal distribution, which is often used to represent natural processes, shows a better fit to the quantum dots' height histogram obtained with the proposed method. Finally, the quantum dots' height obtained were used to calculate the predicted photoluminescence peak energies which were compared with the experimental data. Again, a better match was observed when using the proposed method to evaluate the quantum dots' height. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. [Comparative evaluation of the sensitivity of Acinetobacter to colistin, using the prediffusion and minimum inhibitory concentration methods: detection of heteroresistant isolates].

    PubMed

    Herrera, Melina E; Mobilia, Liliana N; Posse, Graciela R

    2011-01-01

    The objective of this study is to perform a comparative evaluation of the prediffusion and minimum inhibitory concentration (MIC) methods for the detection of sensitivity to colistin, and to detect Acinetobacter baumanii-calcoaceticus complex (ABC) heteroresistant isolates to colistin. We studied 75 isolates of ABC recovered from clinically significant samples obtained from various centers. Sensitivity to colistin was determined by prediffusion as well as by MIC. All the isolates were sensitive to colistin, with MIC = 2µg/ml. The results were analyzed by dispersion graph and linear regression analysis, revealing that the prediffusion method did not correlate with the MIC values for isolates sensitive to colistin (r² = 0.2017). Detection of heteroresistance to colistin was determined by plaque efficiency of all the isolates with the same initial MICs of 2, 1, and 0.5 µg/ml, which resulted in 14 of them with a greater than 8-fold increase in the MIC in some cases. When the sensitivity of these resistant colonies was determined by prediffusion, the resulting dispersion graph and linear regression analysis yielded an r² = 0.604, which revealed a correlation between the methodologies used.

  8. Determination of Urine Albumin by New Simple High-Performance Liquid Chromatography Method.

    PubMed

    Klapkova, Eva; Fortova, Magdalena; Prusa, Richard; Moravcova, Libuse; Kotaska, Karel

    2016-11-01

    A simple high-performance liquid chromatography (HPLC) method was developed for the determination of albumin in patients' urine samples without coeluting proteins and was compared with the immunoturbidimetric determination of albumin. Urine albumin is important biomarker in diabetic patients, but part of it is immuno-nonreactive. Albumin was determined by high-performance liquid chromatography (HPLC), UV detection at 280 nm, Zorbax 300SB-C3 column. Immunoturbidimetric analysis was performed using commercial kit on automatic biochemistry analyzer COBAS INTEGRA ® 400, Roche Diagnostics GmbH, Manheim, Germany. The HLPC method was fully validated. No significant interference with other proteins (transferrin, α-1-acid glycoprotein, α-1-antichymotrypsin, antitrypsin, hemopexin) was found. The results from 301 urine samples were compared with immunochemical determination. We found a statistically significant difference between these methods (P = 0.0001, Mann-Whitney test). New simple HPLC method was developed for the determination of urine albumin without coeluting proteins. Our data indicate that the HPLC method is highly specific and more sensitive than immunoturbidimetry. © 2016 Wiley Periodicals, Inc.

  9. Four methods of attitude determination for spin-stabilized spacecraft with applications and comparative results

    NASA Technical Reports Server (NTRS)

    Smith, G. A.

    1975-01-01

    The attitude of a spacecraft is determined by specifying independent parameters which relate the spacecraft axes to an inertial coordinate system. Sensors which measure angles between spin axis and other vectors directed to objects or fields external to the spacecraft are discussed. For the spin-stabilized spacecraft considered, the spin axis is constant over at least an orbit, but separate solutions based on sensor angle measurements are different due to propagation of errors. Sensor-angle solution methods are described which minimize the propagated errors by making use of least squares techniques over many sensor angle measurements and by solving explicitly (in closed form) for the spin axis coordinates. These methods are compared with star observation solutions to determine if satisfactory accuracy is obtained by each method.

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kurnik, Charles W.; Stoughton, Kate M.; Figueroa, Jorge

    This measurement and verification (M and V) protocol provides procedures for energy service companies (ESCOs) and water efficiency service companies (WESCOs) to determine water savings as a result of water conservation measures (WCMs) in energy performance contracts associated with converting turfgrass or other water-intensive plantings to water-wise and sustainable landscapes. The water savings are determined by comparing the baseline water use to the water use after the WCM has been implemented. This protocol outlines the basic structure of the M and V plan, and details the procedures to use to determine water savings.

  11. Cooling Tower (Evaporative Cooling System) Measurement and Verification Protocol

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kurnik, Charles W.; Boyd, Brian; Stoughton, Kate M.

    This measurement and verification (M and V) protocol provides procedures for energy service companies (ESCOs) and water efficiency service companies (WESCOs) to determine water savings resulting from water conservation measures (WCMs) in energy performance contracts associated with cooling tower efficiency projects. The water savings are determined by comparing the baseline water use to the water use after the WCM has been implemented. This protocol outlines the basic structure of the M and V plan, and details the procedures to use to determine water savings.

  12. Outdoor Irrigation Measurement and Verification Protocol

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kurnik, Charles W.; Stoughton, Kate M.; Figueroa, Jorge

    This measurement and verification (M&V) protocol provides procedures for energy service companies (ESCOs) and water efficiency service companies (WESCOs) to determine water savings resulting from water conservation measures (WCMs) in energy performance contracts associated with outdoor irrigation efficiency projects. The water savings are determined by comparing the baseline water use to the water use after the WCM has been implemented. This protocol outlines the basic structure of the M&V plan, and details the procedures to use to determine water savings.

  13. Probability distribution functions for unit hydrographs with optimization using genetic algorithm

    NASA Astrophysics Data System (ADS)

    Ghorbani, Mohammad Ali; Singh, Vijay P.; Sivakumar, Bellie; H. Kashani, Mahsa; Atre, Atul Arvind; Asadi, Hakimeh

    2017-05-01

    A unit hydrograph (UH) of a watershed may be viewed as the unit pulse response function of a linear system. In recent years, the use of probability distribution functions (pdfs) for determining a UH has received much attention. In this study, a nonlinear optimization model is developed to transmute a UH into a pdf. The potential of six popular pdfs, namely two-parameter gamma, two-parameter Gumbel, two-parameter log-normal, two-parameter normal, three-parameter Pearson distribution, and two-parameter Weibull is tested on data from the Lighvan catchment in Iran. The probability distribution parameters are determined using the nonlinear least squares optimization method in two ways: (1) optimization by programming in Mathematica; and (2) optimization by applying genetic algorithm. The results are compared with those obtained by the traditional linear least squares method. The results show comparable capability and performance of two nonlinear methods. The gamma and Pearson distributions are the most successful models in preserving the rising and recession limbs of the unit hydographs. The log-normal distribution has a high ability in predicting both the peak flow and time to peak of the unit hydrograph. The nonlinear optimization method does not outperform the linear least squares method in determining the UH (especially for excess rainfall of one pulse), but is comparable.

  14. Influence of assessment site in measuring transcutaneous bilirubin

    PubMed Central

    da Conceição, Cristiane Maria; Dornaus, Maria Fernanda Pellegrino da Silva; Portella, Maria Aparecida; Deutsch, Alice D'Agostini; Rebello, Celso Moura

    2014-01-01

    ABSTRACT Objective: To investigate the influence of the site of measurement of transcutaneous bilirubin (forehead or sternum) in reproducibility of results as compared to plasma bilirubin. Methods: A cohort study including 58 term newborns with no hemolytic disease. Transcutaneous measurements were performed on the forehead (halfway between the headline and the glabella, from the left toward the right side, making consecutive determinations, one-centimeter apart) and the sternum (five measurements, from the suprasternal notch to the xiphoid process with consecutive determinations, one-centimeter apart) using Bilicheck® (SpectRx Inc, Norcross, Georgia, USA). The correlation and agreement between both methods and plasma bilirubin were calculated. Results: There was a strong linear correlation between both determinations of serum bilirubin at the forehead and sternum (r=0.704; p<0.01 and r=0.653; p<0.01, respectively). There was correspondence of the mean values of transcutaneous bilirubin measured on the sternum (9.9±2.2mg/dL) compared to plasma levels (10.2±1.7mg/dL), but both differ from the values measured on the forehead (8.6±2.0mg/dL), p<0.05. Conclusion: In newborn term infants with no hemolytic disease, measuring of transcutaneous bilirubin on the sternum had higher accuracy as compared to serum bilirubin measurement on the forehead. PMID:24728239

  15. Probing neutrino mass hierarchy by comparing the charged-current and neutral-current interaction rates of supernova neutrinos

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lai, Kwang-Chang; Leung Center for Cosmology and Particle Astrophysics; Lee, Fei-Fan

    2016-07-22

    The neutrino mass hierarchy is one of the neutrino fundamental properties yet to be determined. We introduce a method to determine neutrino mass hierarchy by comparing the interaction rate of neutral current (NC) interactions, ν(ν-bar)+p→ν(ν-bar)+p, and inverse beta decays (IBD), ν-bar{sub e}+p→n+e{sup +}, of supernova neutrinos in scintillation detectors. Neutrino flavor conversions inside the supernova are sensitive to neutrino mass hierarchy. Due to Mikheyev-Smirnov-Wolfenstein effects, the full swapping of ν-bar{sub e} flux with the ν-bar{sub x} (x=μ, τ) one occurs in the inverted hierarchy, while such a swapping does not occur in the normal hierarchy. As a result, more highmore » energy IBD events occur in the detector for the inverted hierarchy than the high energy IBD events in the normal hierarchy. By comparing IBD interaction rate with the mass hierarchy independent NC interaction rate, one can determine the neutrino mass hierarchy.« less

  16. Probing neutrino mass hierarchy by comparing the charged-current and neutral-current interaction rates of supernova neutrinos

    NASA Astrophysics Data System (ADS)

    Lai, Kwang-Chang; Lee, Fei-Fan; Lee, Feng-Shiuh; Lin, Guey-Lin; Liu, Tsung-Che; Yang, Yi

    2016-07-01

    The neutrino mass hierarchy is one of the neutrino fundamental properties yet to be determined. We introduce a method to determine neutrino mass hierarchy by comparing the interaction rate of neutral current (NC) interactions, ν(bar nu) + p → ν(bar nu) + p, and inverse beta decays (IBD), bar nue + p → n + e+, of supernova neutrinos in scintillation detectors. Neutrino flavor conversions inside the supernova are sensitive to neutrino mass hierarchy. Due to Mikheyev-Smirnov-Wolfenstein effects, the full swapping of bar nue flux with the bar nux (x = μ, τ) one occurs in the inverted hierarchy, while such a swapping does not occur in the normal hierarchy. As a result, more high energy IBD events occur in the detector for the inverted hierarchy than the high energy IBD events in the normal hierarchy. By comparing IBD interaction rate with the mass hierarchy independent NC interaction rate, one can determine the neutrino mass hierarchy.

  17. Reference Determinant Dependence of the Random Phase Approximation in 3d Transition Metal Chemistry.

    PubMed

    Bates, J E; Mezei, P D; Csonka, G I; Sun, J; Ruzsinszky, A

    2017-01-10

    Without extensive fitting, accurate prediction of transition metal chemistry is a challenge for semilocal and hybrid density funcitonals. The Random Phase Approximation (RPA) has been shown to yield superior results to semilocal functionals for main group thermochemistry, but much less is known about its performance for transition metals. We have therefore analyzed the behavior of reaction energies, barrier heights, and ligand dissociation energies obtained with RPA and compare our results to several semilocal and hybrid functionals. Particular attention is paid to the reference determinant dependence of RPA. We find that typically the results do not vary much between semilocal or hybrid functionals as a reference, as long as the fraction of exact exchange (EXX) mixing in the hybrid functional is small. For large fractions of EXX mixing, however, the Hartree-Fock-like nature of the determinant can severely degrade the performance. Overall, RPA systematically reduces the errors of semilocal functionals and delivers excellent performance from a single reference determinant for inherently multireference reactions. The behavior of dual hybrids that combine RPA correlation with a hybrid exchange energy was also explored, but ultimately did not lead to a systematic improvement compared to traditional RPA for these systems. We rationalize this conclusion by decomposing the contributions to the reaction energies, and briefly discuss the possible implications for double-hybrid functionals based on RPA. The correlation between EXX mixing and spin-symmetry breaking is also discussed.

  18. Determination of oestrous cycle of the rats by direct examination: how reliable?

    PubMed

    Yener, T; Turkkani Tunc, A; Aslan, H; Aytan, H; Cantug Caliskan, A

    2007-02-01

    For determination of the oestrous cycle in rats classical Papanicolaou technique has long been used successfully. Instead of using many stains in Papanicolaou, staining the vaginal secretions with only methylene blue has also been defined. Recently a new technique in which vaginal samples are directly examined under light microscope has been introduced. The aim of this study was to assess the reliability of this new technique by comparing it with the classical staining techniques. From 20 Wistar rats 60 vaginal samples were collected with a micropipette, three from each. Briefly, the vagina was flushed two to three times then the fluid was placed onto a glass slide. The fluid was equally distributed onto three glass slides. The glass slides were coded. Two samples were stained with Papanicolaou and methylene blue while the other one was examined directly. Determination of the phases of the oestrous cycle was made by the same histologist who was blinded to the groups and coding system. After determination of the oestrous phase in all samples, the results were compared and it was found that the results were matching. In conclusion, the same results can be obtained with the direct examination technique and this technique is reliable, so there is no need to use relatively time-consuming, less practical and more expensive techniques such as Papanicolaou or methylene blue.

  19. Progress in Noise Thermometry at 505 K and 693 K Using Quantized Voltage Noise Ratio Spectra

    NASA Astrophysics Data System (ADS)

    Tew, W. L.; Benz, S. P.; Dresselhaus, P. D.; Coakley, K. J.; Rogalla, H.; White, D. R.; Labenski, J. R.

    2010-09-01

    Technical advances and new results in noise thermometry at temperatures near the tin freezing point and the zinc freezing point using a quantized voltage noise source (QVNS) are reported. The temperatures are derived by comparing the power spectral density of QVNS synthesized noise with that of Johnson noise from a known resistance at both 505 K and 693 K. Reference noise is digitally synthesized so that the average power spectra of the QVNS match those of the thermal noise, resulting in ratios of power spectra close to unity in the low-frequency limit. Three-parameter models are used to account for differences in impedance-related time constants in the spectra. Direct comparison of noise temperatures to the International Temperature Scale of 1990 (ITS-90) is achieved in a comparison furnace with standard platinum resistance thermometers. The observed noise temperatures determined by operating the noise thermometer in both absolute and relative modes, and related statistics together with estimated uncertainties are reported. The relative noise thermometry results are combined with results from other thermodynamic determinations at temperatures near the tin freezing point to calculate a value of T - T 90 = +4(18) mK for temperatures near the zinc freezing point. These latest results achieve a lower uncertainty than that of our earlier efforts. The present value of T - T 90 is compared to other published determinations from noise thermometry and other methods.

  20. Longevity and Depreciation of Audiovisual Equipment.

    ERIC Educational Resources Information Center

    Post, Richard

    1987-01-01

    Describes results of survey of media service directors at public universities in Ohio to determine the expected longevity of audiovisual equipment. Use of the Delphi technique for estimates is explained, results are compared with an earlier survey done in 1977, and use of spreadsheet software to calculate depreciation is discussed. (LRW)

  1. School Effects on Performance of Minority Pupils.

    ERIC Educational Resources Information Center

    Hofman, W. H. Adriaan

    1994-01-01

    Presents results of a study examining the comparative effects of school (system) determinants on the educational careers of minority students in the Netherlands, drawing on rational choice and empowerment theories. Results indicate the importance of a school policy aimed at improving minority student achievement. Pull-out programs are detrimental,…

  2. A Comparative Analysis of Results Using Three Leadership Style Measurement Instruments.

    DTIC Science & Technology

    The objective of this research was to determine if there was conceptual similarity among leadership styles as measured by the results of the Ohio...hybrid statistic was developed here to measure the degree of association among the leadership styles recorded by each individual respondent. The

  3. The Response of Higher Education to Women's Inequality.

    ERIC Educational Resources Information Center

    Rae, Judith

    The status of academic women is compared with that of men to determine whether disciminating practices and resulting inequality for women continue to exist. Current scientific periodicals, monographs, and books were searched, and the most recent statistics are presented. Results are discussed in terms of admissions, enrollment and degrees earned,…

  4. Instantaneous, phase-averaged, and time-averaged pressure from particle image velocimetry

    NASA Astrophysics Data System (ADS)

    de Kat, Roeland

    2015-11-01

    Recent work on pressure determination using velocity data from particle image velocimetry (PIV) resulted in approaches that allow for instantaneous and volumetric pressure determination. However, applying these approaches is not always feasible (e.g. due to resolution, access, or other constraints) or desired. In those cases pressure determination approaches using phase-averaged or time-averaged velocity provide an alternative. To assess the performance of these different pressure determination approaches against one another, they are applied to a single data set and their results are compared with each other and with surface pressure measurements. For this assessment, the data set of a flow around a square cylinder (de Kat & van Oudheusden, 2012, Exp. Fluids 52:1089-1106) is used. RdK is supported by a Leverhulme Trust Early Career Fellowship.

  5. No Impact of the Analytical Method Used for Determining Cystatin C on Estimating Glomerular Filtration Rate in Children.

    PubMed

    Alberer, Martin; Hoefele, Julia; Benz, Marcus R; Bökenkamp, Arend; Weber, Lutz T

    2017-01-01

    Measurement of inulin clearance is considered to be the gold standard for determining kidney function in children, but this method is time consuming and expensive. The glomerular filtration rate (GFR) is on the other hand easier to calculate by using various creatinine- and/or cystatin C (Cys C)-based formulas. However, for the determination of serum creatinine (Scr) and Cys C, different and non-interchangeable analytical methods exist. Given the fact that different analytical methods for the determination of creatinine and Cys C were used in order to validate existing GFR formulas, clinicians should be aware of the type used in their local laboratory. In this study, we compared GFR results calculated on the basis of different GFR formulas and either used Scr and Cys C values as determined by the analytical method originally employed for validation or values obtained by an alternative analytical method to evaluate any possible effects on the performance. Cys C values determined by means of an immunoturbidimetric assay were used for calculating the GFR using equations in which this analytical method had originally been used for validation. Additionally, these same values were then used in other GFR formulas that had originally been validated using a nephelometric immunoassay for determining Cys C. The effect of using either the compatible or the possibly incompatible analytical method for determining Cys C in the calculation of GFR was assessed in comparison with the GFR measured by creatinine clearance (CrCl). Unexpectedly, using GFR equations that employed Cys C values derived from a possibly incompatible analytical method did not result in a significant difference concerning the classification of patients as having normal or reduced GFR compared to the classification obtained on the basis of CrCl. Sensitivity and specificity were adequate. On the other hand, formulas using Cys C values derived from a compatible analytical method partly showed insufficient performance when compared to CrCl. Although clinicians should be aware of applying a GFR formula that is compatible with the locally used analytical method for determining Cys C and creatinine, other factors might be more crucial for the calculation of correct GFR values.

  6. Comparative Evaluation of Rice Bran Wax as an Ointment Base with Standard Base

    PubMed Central

    Sabale, Vidya; Sabale, P. M.; Lakhotiya, C. L.

    2009-01-01

    Waxes have been used in many cosmetic preparations and pharmaceuticals as formulation aids. Rice bran wax is a byproduct of rice bran oil industry. Present investigation has been aimed to explore the possible utility of rice bran wax as ointment base compared to standard base. The rice bran wax obtained, purified and its physicochemical characteristics were determined. Ointment base acts as a carrier for medicaments. The ointment base composition determines not only the extent of penetration but also controls the transfer of medicaments from the base to the body tissues. Rice bran wax base was compared with standard base for appearance, spreadability, water number, wash ability and diffusibility. The results show that rice bran wax acts as an ointment base as far as its pharmaceutical properties are concerned and it could effectively replace comparatively costlier available ointment bases. PMID:20177466

  7. Finite Element Study of a Lumbar Intervertebral Disc Nucleus Replacement Device.

    PubMed

    Coogan, Jessica S; Francis, W Loren; Eliason, Travis D; Bredbenner, Todd L; Stemper, Brian D; Yoganandan, Narayan; Pintar, Frank A; Nicolella, Daniel P

    2016-01-01

    Nucleus replacement technologies are a minimally invasive alternative to spinal fusion and total disc replacement that have the potential to reduce pain and restore motion for patients with degenerative disc disease. Finite element modeling can be used to determine the biomechanics associated with nucleus replacement technologies. The current study focuses on a new nucleus replacement device designed as a conforming silicone implant with an internal void. A validated finite element model of the human lumbar L3-L4 motion segment was developed and used to investigate the influence of the nucleus replacement device on spine biomechanics. In addition, the effect of device design changes on biomechanics was determined. A 3D, L3-L4 finite element model was constructed from medical imaging data. Models were created with the normal intact nucleus, the nucleus replacement device, and a solid silicone implant. Probabilistic analysis was performed on the normal model to provide quantitative validation metrics. Sensitivity analysis was performed on the silicone Shore A durometer of the device. Models were loaded under axial compression followed by flexion/extension, lateral bending, or axial rotation. Compressive displacement, endplate stresses, reaction moment, and annulus stresses were determined and compared between the different models. The novel nucleus replacement device resulted in similar compressive displacement, endplate stress, and annulus stress and slightly higher reaction moment compared with the normal nucleus. The solid implant resulted in decreased displacement, increased endplate stress, decreased annulus stress, and decreased reaction moment compared with the novel device. With increasing silicone durometer, compressive displacement decreased, endplate stress increased, reaction moment increased, and annulus stress decreased. Finite element analysis was used to show that the novel nucleus replacement device results in similar biomechanics compared with the normal intact nucleus.

  8. Finite Element Study of a Lumbar Intervertebral Disc Nucleus Replacement Device

    PubMed Central

    Coogan, Jessica S.; Francis, W. Loren; Eliason, Travis D.; Bredbenner, Todd L.; Stemper, Brian D.; Yoganandan, Narayan; Pintar, Frank A.; Nicolella, Daniel P.

    2016-01-01

    Nucleus replacement technologies are a minimally invasive alternative to spinal fusion and total disc replacement that have the potential to reduce pain and restore motion for patients with degenerative disc disease. Finite element modeling can be used to determine the biomechanics associated with nucleus replacement technologies. The current study focuses on a new nucleus replacement device designed as a conforming silicone implant with an internal void. A validated finite element model of the human lumbar L3–L4 motion segment was developed and used to investigate the influence of the nucleus replacement device on spine biomechanics. In addition, the effect of device design changes on biomechanics was determined. A 3D, L3–L4 finite element model was constructed from medical imaging data. Models were created with the normal intact nucleus, the nucleus replacement device, and a solid silicone implant. Probabilistic analysis was performed on the normal model to provide quantitative validation metrics. Sensitivity analysis was performed on the silicone Shore A durometer of the device. Models were loaded under axial compression followed by flexion/extension, lateral bending, or axial rotation. Compressive displacement, endplate stresses, reaction moment, and annulus stresses were determined and compared between the different models. The novel nucleus replacement device resulted in similar compressive displacement, endplate stress, and annulus stress and slightly higher reaction moment compared with the normal nucleus. The solid implant resulted in decreased displacement, increased endplate stress, decreased annulus stress, and decreased reaction moment compared with the novel device. With increasing silicone durometer, compressive displacement decreased, endplate stress increased, reaction moment increased, and annulus stress decreased. Finite element analysis was used to show that the novel nucleus replacement device results in similar biomechanics compared with the normal intact nucleus. PMID:27990418

  9. Discrete sensors distribution for accurate plantar pressure analyses.

    PubMed

    Claverie, Laetitia; Ille, Anne; Moretto, Pierre

    2016-12-01

    The aim of this study was to determine the distribution of discrete sensors under the footprint for accurate plantar pressure analyses. For this purpose, two different sensor layouts have been tested and compared, to determine which was the most accurate to monitor plantar pressure with wireless devices in research and/or clinical practice. Ten healthy volunteers participated in the study (age range: 23-58 years). The barycenter of pressures (BoP) determined from the plantar pressure system (W-inshoe®) was compared to the center of pressures (CoP) determined from a force platform (AMTI) in the medial-lateral (ML) and anterior-posterior (AP) directions. Then, the vertical ground reaction force (vGRF) obtained from both W-inshoe® and force platform was compared for both layouts for each subject. The BoP and vGRF determined from the plantar pressure system data showed good correlation (SCC) with those determined from the force platform data, notably for the second sensor organization (ML SCC= 0.95; AP SCC=0.99; vGRF SCC=0.91). The study demonstrates that an adjusted placement of removable sensors is key to accurate plantar pressure analyses. These results are promising for a plantar pressure recording outside clinical or laboratory settings, for long time monitoring, real time feedback or for whatever activity requiring a low-cost system. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.

  10. Direct determination of the number-weighted mean radius and polydispersity from dynamic light-scattering data.

    PubMed

    Patty, Philipus J; Frisken, Barbara J

    2006-04-01

    We compare results for the number-weighted mean radius and polydispersity obtained either by directly fitting number distributions to dynamic light-scattering data or by converting results obtained by fitting intensity-weighted distributions. We find that results from fits using number distributions are angle independent and that converting intensity-weighted distributions is not always reliable, especially when the polydispersity of the sample is large. We compare the results of fitting symmetric and asymmetric distributions, as represented by Gaussian and Schulz distributions, respectively, to data for extruded vesicles and find that the Schulz distribution provides a better estimate of the size distribution for these samples.

  11. Data from fitting Gaussian process models to various data sets using eight Gaussian process software packages.

    PubMed

    Erickson, Collin B; Ankenman, Bruce E; Sanchez, Susan M

    2018-06-01

    This data article provides the summary data from tests comparing various Gaussian process software packages. Each spreadsheet represents a single function or type of function using a particular input sample size. In each spreadsheet, a row gives the results for a particular replication using a single package. Within each spreadsheet there are the results from eight Gaussian process model-fitting packages on five replicates of the surface. There is also one spreadsheet comparing the results from two packages performing stochastic kriging. These data enable comparisons between the packages to determine which package will give users the best results.

  12. Determination of zircon/melt trace element partition coefficients from SIMS analysis of melt inclusions in zircon

    NASA Astrophysics Data System (ADS)

    Thomas, J. B.; Bodnar, R. J.; Shimizu, N.; Sinha, A. K.

    2002-09-01

    Partition coefficients ( zircon/meltD M) for rare earth elements (REE) (La, Ce, Nd, Sm, Dy, Er and Yb) and other trace elements (Ba, Rb, B, Sr, Ti, Y and Nb) between zircon and melt have been calculated from secondary ion mass spectrometric (SIMS) analyses of zircon/melt inclusion pairs. The melt inclusion-mineral (MIM) technique shows that D REE increase in compatibility with increasing atomic number, similar to results of previous studies. However, D REE determined using the MIM technique are, in general, lower than previously reported values. Calculated D REE indicate that light REE with atomic numbers less than Sm are incompatible in zircon and become more incompatible with decreasing atomic number. This behavior is in contrast to most previously published results which indicate D > 1 and define a flat partitioning pattern for elements from La through Sm. The partition coefficients for the heavy REE determined using the MIM technique are lower than previously published results by factors of ≈15 to 20 but follow a similar trend. These differences are thought to reflect the effects of mineral and/or glass contaminants in samples from earlier studies which employed bulk analysis techniques. D REE determined using the MIM technique agree well with values predicted using the equations of Brice (1975), which are based on the size and elasticity of crystallographic sites. The presence of Ce 4+ in the melt results in elevated D Ce compared to neighboring REE due to the similar valence and size of Ce 4+ and Zr 4+. Predicted zircon/meltD values for Ce 4+ and Ce 3+ indicate that the Ce 4+/Ce 3+ ratios of the melt ranged from about 10 -3 to 10 -2. Partition coefficients for other trace elements determined in this study increase in compatibility in the order Ba < Rb < B < Sr < Ti < Y < Nb, with Ba, Rb, B and Sr showing incompatible behavior (D M < 1.0), and Ti, Y and Nb showing compatible behavior (D M > 1.0). The effect of partition coefficients on melt evolution during petrogenetic modeling was examined using partition coefficients determined in this study and compared to trends obtained using published partition coefficients. The lower D REE determined in this study result in smaller REE bulk distribution coefficients, for a given mineral assemblage, compared to those calculated using previously reported values. As an example, fractional crystallization of an assemblage composed of 35% hornblende, 64.5% plagioclase and 0.5% zircon produces a melt that becomes increasingly more enriched in Yb using the D Yb from this study. Using D Yb from Fujimaki (1986) results in a melt that becomes progressively depleted in Yb during crystallization.

  13. [The growth behavior of mouse fibroblasts on intraocular lens surface of various silicone and PMMA materials].

    PubMed

    Kammann, J; Kreiner, C F; Kaden, P

    1994-08-01

    Experience with intraocular lenses (IOL) made of PMMA dates back ca. 40 years, while silicone IOLs have been in use for only about 10 years. The biocompatibility of PMMA and silicone caoutchouc was tested in a comparative study investigating the growth of mouse fibroblasts on different IOL materials. Spectrophotometric determination of protein synthesis and liquid scintillation counting of DNA synthesis were carried out. The spreading of cells was planimetrically determined, and the DNA synthesis of individual cells in direct contact with the test sample was tested. The results showed that the biocompatibility of silicone lenses made of purified caoutchouc is comparable with that of PMMA lenses; there is no statistically significant difference. However, impurities arising during material synthesis result in a statistically significant inhibition of cell growth on the IOL surfaces.

  14. Integrated pest management of "Golden Delicious" apples.

    PubMed

    Simončič, A; Stopar, M; Velikonja Bolta, Š; Bavčar, D; Leskovšek, R; Baša Česnik, H

    2015-01-01

    Monitoring of plant protection product (PPP) residues in "Golden Delicious" apples was performed in 2011-2013, where 216 active substances were analysed with three analytical methods. Integrated pest management (IPM) production and improved IPM production were compared. Results were in favour of improved IPM production. Some active compounds determined in IPM production (boscalid, pyraclostrobin, thiacloprid and thiametoxam) were not found in improved IPM production. Besides that, in 2011 and 2012, captan residues were lower in improved IPM production. Risk assessment was also performed. Chronic exposure of consumers was low in general, but showed no major differences for IPM and improved IPM production for active substances determined in both types of production. Analytical results were compared with the European Union report of 2010 where 1.3% of apple samples exceeded maximum residue levels (MRLs), while MRL exceedances were not observed in this survey.

  15. A systematic review of postoperative hand therapy management of basal joint arthritis.

    PubMed

    Wolfe, Terri; Chu, Jennifer Y; Woods, Tammy; Lubahn, John D

    2014-04-01

    There are a variety of postoperative immobilization and therapy options for patients with basal joint arthritis. Although prior systematic reviews have compared surgical procedures used to treat basal joint arthritis, none to our knowledge compares therapy protocols for this condition, which are considered an important part of the treatment. (1) We sought to determine whether differences in the length and type of postoperative immobilization affect clinical results after basal joint arthritis surgery. (2) We also compared specific therapy protocols that were prescribed. (3) Finally, we evaluated published protocols to determine when patients were released to full activity to see whether these appeared to affect clinical results. A systematic review of English-language studies in the PubMed and Cochrane databases was performed. Studies were then reviewed to determine what postoperative immobilization and therapy protocols the authors used and when patients were released to full activities. A total of 19 studies were identified using the search criteria. All but one of the studies included a postoperative period of immobilization in either a cast or splint. Immobilization time varied depending on whether Kirschner wires were used for the surgery and whether an implant was placed. Postoperative therapy protocols also varied but followed three general patterns. Some therapy protocols involved teaching patients a home exercise program only, whereas some authors described routine referral to a therapist. The third group consisted of studies in which patients were only referred for therapy if the physicians determined it was necessary during followup. Many studies did not give a specific time for full return to activity and instead described a gradual transition to full activity after immobilization was discontinued. Because of the variability and small numbers, no conclusive recommendations could be made on any of the three study questions. Comparative, multicenter studies comparing different immobilization and therapy protocols after the surgical treatment of basal joint arthritis would be helpful for both surgeons and therapists looking to refine their treatment protocols.

  16. Hereditary antigen characteristics of blood in ischemic cerebrovascular accident.

    PubMed

    Sostarić, V; Bozicević, D; Brinar, V; Grbavac, Z

    1991-01-01

    In order to determine genetic differences between 50 examinees with ischemic cerebrovascular accident (iCVA) and those of comparative group, we have chosen 1883 persons from phenotypic healthy population divided into 5 different subgroups. The purpose of our investigation was exploring hereditary characteristics of antigenes linked to erythrocyte membrane. The highest discriminating value in genetic distance had MN and ABO genetic loci. The frequency of M antigen in stroke patients was 70% (in the comparative group 55%), N antigen had frequency 30% in patients with iCVA and 45% in the comparative group. The frequency of the blood group A in the patients with iCV was 32.68% and 27.16% in the comparative group. Blood group B had frequency in the patients 10.69% and in the comparative group 6.72%. O blood group had frequency in the patients 56.73% and in the comparative group 66.12%. Genetic distance between patients with iCVA and the comparative group were determined with gene frequencies, that was shown on the dendrogram. The dendrogram clearly shows that patients with iCVA are separated from all other comparative subgroups. The results of our investigation presented the highest discriminating value of MN and ABO genetic loci. The possibility of linkage between genetic loci for these erithrocyte antigenes (on the 4th and 9th chromosome) and genetic loci which determine iCVA cannot be excluded. Finally we consider that this method can support earlier identification of persons who belong to "high risk group for cerebrovascular disease".

  17. Comparison of hand and semiautomatic tracing methods for creating maxillofacial artificial organs using sequences of computed tomography (CT) and cone beam computed tomography (CBCT) images.

    PubMed

    Szabo, Bence T; Aksoy, Seçil; Repassy, Gabor; Csomo, Krisztian; Dobo-Nagy, Csaba; Orhan, Kaan

    2017-06-09

    The aim of this study was to compare the paranasal sinus volumes obtained by manual and semiautomatic imaging software programs using both CT and CBCT imaging. 121 computed tomography (CT) and 119 cone beam computed tomography (CBCT) examinations were selected from the databases of the authors' institutes. The Digital Imaging and Communications in Medicine (DICOM) images were imported into 3-dimensonal imaging software, in which hand mode and semiautomatic tracing methods were used to measure the volumes of both maxillary sinuses and the sphenoid sinus. The determined volumetric means were compared to previously published averages. Isometric CBCT-based volume determination results were closer to the real volume conditions, whereas the non-isometric CT-based volume measurements defined coherently lower volumes. By comparing the 2 volume measurement modes, the values gained from hand mode were closer to the literature data. Furthermore, CBCT-based image measurement results corresponded to the known averages. Our results suggest that CBCT images provide reliable volumetric information that can be depended on for artificial organ construction, and which may aid the guidance of the operator prior to or during the intervention.

  18. Cocaine abuse determination by ion mobility spectrometry using molecular imprinting.

    PubMed

    Sorribes-Soriano, A; Esteve-Turrillas, F A; Armenta, S; de la Guardia, M; Herrero-Martínez, J M

    2017-01-20

    A cocaine-based molecular imprinted polymer (MIP) has been produced by bulk polymerization and employed as selective solid-phase extraction support for the determination of cocaine in saliva samples by ion mobility spectrometry (IMS). The most appropriate conditions for washing and elution of cocaine from MIPs were studied and MIPs were characterized in terms of analyte binding capacity, reusability in water and saliva analysis, imprinting factor and selectivity were established and compared with non-imprinted polymers. The proposed MIP-IMS method provided a LOD of 18μgL -1 and quantitative recoveries for blank saliva samples spiked from 75 to 500μgL -1 cocaine. Oral fluid samples were collected from cocaine consumers and analysed by the proposed MIP-IMS methodology. Results, ranging from below the LOD to 51±2mgL -1 , were statistically comparable to those obtained by a confirmatory gas chromatography-mass spectrometry method. Moreover, results were compared to a qualitative lateral flow immunoassay procedure providing similar classification of the samples. Thus, MIP-IMS can be considered an useful alternative that provided fast, selective and sensitive results with a cost affordable instrumentation that does not require skilled operators. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Experimental clean combustor program, phase 3: Noise measurement addendum. [CF6-50 high bypass turbofan engine noise

    NASA Technical Reports Server (NTRS)

    Doyle, V. L.

    1978-01-01

    The acoustic characteristics of the double annular combustor in a CF6-50 high bypass turbofan engine were investigated. Internal fluctuating pressure measurements were made in the combustor region and in the core exhaust. The transmission loss across the turbine and nozzle was determined from the measurements and compared to previous component results and present theory. The primary noise source location in the combustor was investigated. Spectral comparisons of test rig results were made with the engine results. The measured overall power level was compared with component and engine correlating parameters.

  20. Energy consumption in terms of shear stress for two types of membrane bioreactors used for municipal wastewater treatment processes

    NASA Astrophysics Data System (ADS)

    Ratkovich, Nicolas; Bentzen, Thomas R.; Rasmussen, Michael R.

    2012-10-01

    Two types of submerged membrane bioreactors (MBR): hollow fiber (HF) and hollow sheet (HS), have been studied and compared in terms of energy consumption and average shear stress over the membrane wall. The analysis of energy consumption was made using the correlation to determine the blower power and the blower power demand per unit of permeate volume. Results showed that for the system geometries considered, in terms the of the blower power, the HF MBR requires less power compared to HS MBR. However, in terms of blower power per unit of permeate volume, the HS MBR requires less energy. The analysis of shear stress over the membrane surface was made using computational fluid dynamics (CFD) modelling. Experimental measurements for the HF MBR were compared with the CFD model and an error less that 8% was obtained. For the HS MBR, experimental measurements of velocity profiles were made and an error of 11% was found. This work uses an empirical relationship to determine the shear stress based on the ratio of aeration blower power to tank volume. This relationship is used in bubble column reactors and it is extrapolate to determine shear stress on MBR systems. This relationship proved to be overestimated by 28% compared to experimental measurements and CFD results. Therefore, a corrective factor is included in the relationship in order to account for the membrane placed inside the bioreactor.

  1. Low sensitivity of implant sonication when screening for infection in revision surgery

    PubMed Central

    Van Diek, Floor M; Albers, Christiaan G M; Van Hooff, Miranda L; Meis, Jacques F; Goosen, Jon H M

    2017-01-01

    Background and purpose Prosthetic-joint infection (PJI) is the most serious complication of arthroplasty, and accurate identification of a potentially responsible microorganism is essential for successful antibiotic treatment. We therefore determined the diagnostic accuracy of sonication and compared it with tissue culture as a screening tool in detecting prosthetic joint infection in revision arthroplasty. Patients and methods 252 consecutive revision arthroplasty cases were enrolled. These cases were determined as being suspected or unsuspected of having infection according to standard criteria. Perioperatively, 6 periprosthetic interface tissue biopsies were obtained from each patient and the implants removed were sonicated. The sensitivity and specificity of periprosthetic tissue culture and sonication fluid cultures were determined. Results Preoperatively, 75 revision cases were classified as having PJI (33 early and 42 late) and 177 were unsuspected of having infection. Compared with tissue culture, the sensitivity of the sonication fluid analysis was low: 0.47 (95% CI: 0.35–0.59) for sonication as compared to 0.68 (95% CI: 0.56–0.78) for tissue culture. The specificity of the sonication fluid analysis was higher than that for tissue culture: 0.99 (95% CI: 0.96–1.0) as compared to 0.80 (95% CI: 0.74–0.86). Interpretation Sonication is a highly specific test for diagnosis of PJI. However, due to the low sensitivity, a negative sonication result does not rule out the presence of PJI. Thus, sonication is not of value for screening of microorganisms during revision surgery. PMID:28287012

  2. Ion time-of-flight determinations of doubly to singly ionized mercury ion ratios from a mercury electron bombardment discharge

    NASA Technical Reports Server (NTRS)

    Sellen, J. M., Jr.; Kemp, R. F.; Hall, D. F.

    1973-01-01

    Doubly to singly charged mercury ion ratios in electron bombardment ion thruster exhaust beams have been determined as functions of bombardment discharge potential, thrust beam current, thrust beam radial position, acceleration-deceleration voltage ratio, and propellant utilization fraction. A mathematical model for two-step ionization processes has been derived, and calculated ion ratios are compared to observed ratios. Production of Hg(++) appears to result primarily from sequential ionization of Hg(+) in the discharge. Experimental and analytical results are presented, and design, construction, and operation features of an electrostatic deflection ion time-of-flight analyzer for the determination of the above-mentioned ratios are reviewed.

  3. GEOS observation systems intercomparison investigation results

    NASA Technical Reports Server (NTRS)

    Berbert, J. H.

    1974-01-01

    The results of an investigation designed to determine the relative accuracy and precision of the different types of geodetic observation systems used by NASA is presented. A collocation technique was used to minimize the effects of uncertainties in the relative station locations and in the earth's gravity field model by installing accurate reference tracking systems close to the systems to be compared, and by precisely determining their relative survey. The Goddard laser and camera systems were shipped to selected sites, where they tracked the GEOS satellite simultaneously with other systems for an intercomparison observation.

  4. Analytical application of solid contact ion-selective electrodes for determination of copper and nitrate in various food products and drinking water.

    PubMed

    Wardak, Cecylia; Grabarczyk, Malgorzata

    2016-08-02

    A simple, fast and cheap method for monitoring copper and nitrate in drinking water and food products using newly developed solid contact ion-selective electrodes is proposed. Determination of copper and nitrate was performed by application of multiple standard additions technique. The reliability of the obtained results was assessed by comparing them using the anodic stripping voltammetry or spectrophotometry for the same samples. In each case, satisfactory agreement of the results was obtained, which confirms the analytical usefulness of the constructed electrodes.

  5. Natural frequencies of thin rectangular plates clamped on contour using the Finite Element Method

    NASA Astrophysics Data System (ADS)

    (Barboni Haţiegan, L.; Haţiegan, C.; Gillich, G. R.; Hamat, C. O.; Vasile, O.; Stroia, M. D.

    2018-01-01

    This paper presents the determining of natural frequencies of plates without and with damages using the finite element method of SolidWorks program. The first thirty natural frequencies obtained for thin rectangular rectangular plates clamped on contour without and with central damages a for different dimensions. The relative variation of natural frequency was determined and the obtained results by the finite element method (FEM) respectively relative variation of natural frequency, were graphically represented according to their vibration natural modes. Finally, the obtained results were compared.

  6. Time-resolved photon emission from layered turbid media

    NASA Astrophysics Data System (ADS)

    Hielscher, Andreas H.; Liu, Hanli; Chance, Britton; Tittel, Frank K.; Jacques, Steven L.

    1996-02-01

    We present numerical and experimental results of time-resolved emission profiles from various layered turbid media. Numerical solutions determined by time-resolved Monte Carlo simulations are compared with measurements on layered-tissue phantoms made from gelatin. In particular, we show that in certain cases the effects of the upper layers can be eliminated. As a practical example, these results are used to analyze in vivo measurements on the human head. This demonstrates the influence of skin, skull, and meninges on the determination of the blood oxygenation in the brain.

  7. Experimental determination of ablation vapor species from carbon phenolic heat-shield materials

    NASA Technical Reports Server (NTRS)

    Lincoln, K. A.

    1981-01-01

    The relative concentrations of vapors produced from carbon phenolic composites under thermal loadings approximating those expected at peak heating during vehicle entry into the atmospheres of the outer planets have been determined. The technique of vaporizing the surface of bulk samples by laser irradiation while measuring in situ the vapor species by mass spectrometry is described. Results show that vapor composition varies with irradiance level and with depth of heating (or extent of pyrolysis). Attempts are made to compare these experimental results with the theoretical predictions from computer codes.

  8. Rapid determination of 237Np in soil samples by multi-collector inductively-coupled plasma mass spectrometry and gamma spectrometry.

    PubMed

    Yi, Xiaowei; Shi, Yanmei; Xu, Jiang; He, Xiaobing; Zhang, Haitao; Lin, Jianfeng

    A radiochemical procedure is developed for the determination of 237 Np in soil with multi-collector inductively-coupled plasma mass spectrometry (MC-ICP-MS) and gamma-spectrometry. 239 Np (milked from 243 Am) was used as an isotopic tracer for chemical yield determination. The neptunium in the soil is separated by thenoyl-trifluoracetone extraction from 1 M HNO 3 solution after reducing Np to Np(IV) with ferrous sulfamate, and then purified with Dowex 1 × 2 anion exchange resin. 239 Np in the resulting solution is measured with gamma-spectrometry for chemical yield determination while the 237 Np is measured with MC-ICP-MS. Measurement results for soil samples are presented together with those for two reference samples. By comparing the determined value with the reference value of the 237 Np activity concentration, the feasibility of the procedure was validated.

  9. A fast determination method for transverse relaxation of spin-exchange-relaxation-free magnetometer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lu, Jixi, E-mail: lujixi@buaa.edu.cn; Qian, Zheng; Fang, Jiancheng

    2015-04-15

    We propose a fast and accurate determination method for transverse relaxation of the spin-exchange-relaxation-free (SERF) magnetometer. This method is based on the measurement of magnetic resonance linewidth via a chirped magnetic field excitation and the amplitude spectrum analysis. Compared with the frequency sweeping via separate sinusoidal excitation, our method can realize linewidth determination within only few seconds and meanwhile obtain good frequency resolution. Therefore, it can avoid the drift error in long term measurement and improve the accuracy of the determination. As the magnetic resonance frequency of the SERF magnetometer is very low, we include the effect of the negativemore » resonance frequency caused by the chirp and achieve the coefficient of determination of the fitting results better than 0.998 with 95% confidence bounds to the theoretical equation. The experimental results are in good agreement with our theoretical analysis.« less

  10. A Comparative Analysis of Meeting the Whole Child Initiatives through Standardized and Competency-Based Education Systems in Terms of Achievement and Meeting the Whole Child Initiatives: Comparing Professional Perceptions and Identified Measurable Results

    ERIC Educational Resources Information Center

    Ward, Jacqueline M.

    2011-01-01

    Traditional education (TE) largely uses a standardized (SbE) approach while alternatives (nTE) tend to more of a competency (CbE), or student-centered approach. This comparative analysis examines essential aspects of such pedagogies in determining the effectiveness of schooling systems in meeting the Whole Child Initiative (Souza, 1999; Carter et…

  11. Comparative Tests of Pitot-static Tubes

    NASA Technical Reports Server (NTRS)

    Merriam, Kenneth G; Spaulding, Ellis R

    1935-01-01

    Comparative tests were made on seven conventional Pitot-static tubes to determine their static, dynamic, and resultant errors. The effect of varying the dynamic opening, static opening, wall thickness, and inner-tube diameter was investigated. Pressure-distribution measurements showing stem and tip effects were also made. A tentative design for a standard Pitot-static tube for use in measuring air velocity is submitted.

  12. Choice of Target Population Weights in Rater Comparability Scoring and Equating. Research Report. ETS RR-13-03

    ERIC Educational Resources Information Center

    Puhan, Gautam

    2013-01-01

    The purpose of this study was to demonstrate that the choice of sample weights when defining the target population under poststratification equating can be a critical factor in determining the accuracy of the equating results under a unique equating scenario, known as "rater comparability scoring and equating." The nature of data…

  13. Study of Planck's Law with a Small USB Grating Spectrometer

    ERIC Educational Resources Information Center

    Navratil, Zdenek; Dosoudilova, Lenka; Jurmanova, Jana

    2013-01-01

    In this paper an experiment to study Planck's radiation law is presented. The spectra of a heated furnace and of a halogen lamp under various conditions were measured with a small USB grating spectrometer and fitted using Planck's law. The temperature determined from the fit was then compared with the results of comparative temperature…

  14. The Comparison of Turkish Students' PISA Achievement Levels by Year via Data Envelopment Analysis

    ERIC Educational Resources Information Center

    Yalçin, Seher; Tavsancil, Ezel

    2014-01-01

    This research aimed to determine the relative efficiency of the types of school common to three administrations of the PISA (2003-2006-2009) by comparing their results, along with the activities that are to be performed for inefficient school types and changes in the efficiency value of the school types by year. The comparative analysis was based…

  15. Performance of the Alere Determine™ HIV-1/2 Ag/Ab Combo Rapid Test with algorithm-defined acute HIV-1 infection specimens.

    PubMed

    Parker, Monica M; Bennett, S Berry; Sullivan, Timothy J; Fordan, Sally; Wesolowski, Laura G; Wroblewski, Kelly; Gaynor, Anne M

    2018-05-14

    The capacity of HIV Antigen/Antibody (Ag/Ab) immunoassays (IA) to detect HIV-1 p24 antigen has resulted in improved detection of HIV-1 infections in comparison to Ab-only screening assays. Since its introduction in the US, studies have shown that the Determine HIV-1/2 Ag/Ab Combo assay (Determine Ag/Ab) detects HIV infection earlier than laboratory-based IgM/IgG-sensitive IAs, but its sensitivity for HIV-1 p24 Ag detection is reduced compared to laboratory-based Ag/Ab assays. However, further evaluation is needed to assess its capacity to detect acute HIV-1 infection. To assess the performance of Determine Ag/Ab in serum from acute HIV-1 infections. Select serum specimens that screened reactive on a laboratory-based Ag/Ab IA or IgM/IgG Ab-only IA, with a negative or indeterminate supplemental antibody test and detectable HIV-1 RNA were retrospectively tested with Determine Ag/Ab. Results were compared with those of the primary screening immunoassay to evaluate concordance within this set of algorithm-defined acute infections. Of 159 algorithm-defined acute HIV-1 specimens, Determine Ag/Ab was reactive for 105 resulting in 66.0% concordance. Of 125 that were initially detected by a laboratory-based Ag/Ab IA, 81 (64.8%) were reactive by Determine Ag/Ab. A total of 34 acute specimens were initially detected by a laboratory-based IgM/IgG Ab-only IA and 24 (70.6%) of those were reactive by Determine Ag/Ab. Due to their enhanced sensitivity, laboratory-based Ag/Ab IAs continue to be preferred over the Determine Ag/Ab as the screening method used by laboratories conducting HIV diagnostic testing on serum and plasma specimens. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  16. Automation of the Image Analysis for Thermographic Inspection

    NASA Technical Reports Server (NTRS)

    Plotnikov, Yuri A.; Winfree, William P.

    1998-01-01

    Several data processing procedures for the pulse thermal inspection require preliminary determination of an unflawed region. Typically, an initial analysis of the thermal images is performed by an operator to determine the locations of unflawed and the defective areas. In the present work an algorithm is developed for automatically determining a reference point corresponding to an unflawed region. Results are obtained for defects which are arbitrarily located in the inspection region. A comparison is presented of the distributions of derived values with right and wrong localization of the reference point. Different algorithms of automatic determination of the reference point are compared.

  17. Comparative study of inorganic elements determined in whole blood from Dmd(mdx)/J mice strain by EDXRF and NAA analytical techniques.

    PubMed

    Redígolo, M M; Sato, I M; Metairon, S; Zamboni, C B

    2016-04-01

    Several diseases can be diagnosed observing the variation of specific elements concentration in body fluids. In this study the concentration of inorganic elements in blood samples of dystrophic (Dmd(mdx)/J) and C57BL/6J (control group) mice strain were determined. The results obtained from Energy Dispersive X-ray Fluorescence (EDXRF) were compared with Neutron Activation Analysis (NAA) technique. Both analytical techniques showed to be appropriate and complementary offering a new contribution for veterinary medicine as well as detailed knowledge of this pathology. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Thermal models applicable for visual and infrared studies of orbital debris

    NASA Technical Reports Server (NTRS)

    Lebofsky, Larry A.; Vilas, Faith

    1990-01-01

    Over the past decade, thermal models have been developed for the determination of asteroid diameters and albedos. As a first step to understanding the size/frequency distribution of the debris population in earth orbit, these thermal models have been modified to determine the sizes of orbiting debris. When possible, the model results have been compared to spherical satellites of known diameter.

  19. Concurrent determination of total serum calcium and magnesium by thermometric titration with ethylenediaminetetraacetate.

    PubMed

    Callicott, R H; Carr, P W

    1976-07-01

    Total serum calcium and magnesium may be determined in one thermometric titration, with disodium ethylenediaminetetraacetate as the titrant. A 1-ml serum sample is diluted with 1 ml of tris(hydroxymethyl)aminomethane buffer (pH 8) and titrated at a constant rate with a motorized syringe buret. Results by the thermometric method compared well with those by atomic absorption spectroscopy.

  20. Markets, Government Policy, and China’s Timber Supply

    Treesearch

    Han Zhang; Joseph Buongiorno

    2012-01-01

    China’s domestic demand and exports of wood products are rising rapidly compared to domestic supply. The determinants of timber supply in China were investigated with panel data from 25 provinces from 1999 to 2009. The results indicated that China’s timber supply had responded to both market forces, reflected by timber prices largely determined by world demand and...

  1. Using a Regression Discontinuity Design to Determine the Effectiveness of a Vocabulary Intervention for At-Risk First-Grade Readers

    ERIC Educational Resources Information Center

    Ashworth, Kristen E.

    2012-01-01

    The purposes of this study were to determine the effectiveness of a vocabulary intervention for first-grade students at risk for reading and language difficulties and to compare the results of a regression discontinuity design to those of an experimental design. The specific research questions were: (1) Do first-graders who are at risk of reading…

  2. Comparison of VFA titration procedures used for monitoring the biogas process.

    PubMed

    Lützhøft, Hans-Christian Holten; Boe, Kanokwan; Fang, Cheng; Angelidaki, Irini

    2014-05-01

    Titrimetric determination of volatile fatty acids (VFAs) contents is a common way to monitor a biogas process. However, digested manure from co-digestion biogas plants has a complex matrix with high concentrations of interfering components, resulting in varying results when using different titration procedures. Currently, no standardized procedure is used and it is therefore difficult to compare the performance among plants. The aim of this study was to evaluate four titration procedures (for determination of VFA-levels of digested manure samples) and compare results with gas chromatographic (GC) analysis. Two of the procedures are commonly used in biogas plants and two are discussed in literature. The results showed that the optimal titration results were obtained when 40 mL of four times diluted digested manure was gently stirred (200 rpm). Results from samples with different VFA concentrations (1-11 g/L) showed linear correlation between titration results and GC measurements. However, determination of VFA by titration generally overestimated the VFA contents compared with GC measurements when samples had low VFA concentrations, i.e. around 1 g/L. The accuracy of titration increased when samples had high VFA concentrations, i.e. around 5 g/L. It was further found that the studied ionisable interfering components had lowest effect on titration when the sample had high VFA concentration. In contrast, bicarbonate, phosphate and lactate had significant effect on titration accuracy at low VFA concentration. An extended 5-point titration procedure with pH correction was best to handle interferences from bicarbonate, phosphate and lactate at low VFA concentrations. Contrary, the simplest titration procedure with only two pH end-points showed the highest accuracy among all titration procedures at high VFA concentrations. All in all, if the composition of the digested manure sample is not known, the procedure with only two pH end-points should be the procedure of choice, due to its simplicity and accuracy. Copyright © 2014 Elsevier Ltd. All rights reserved.

  3. Metrological characterization of X-ray diffraction methods at different acquisition geometries for determination of crystallite size in nano-scale materials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Uvarov, Vladimir, E-mail: vladimiru@savion.huji.ac.il; Popov, Inna

    2013-11-15

    Crystallite size values were determined by X-ray diffraction methods for 183 powder samples. The tested size range was from a few to about several hundred nanometers. Crystallite size was calculated with direct use of the Scherrer equation, the Williamson–Hall method and the Rietveld procedure via the application of a series of commercial and free software. The results were statistically treated to estimate the significance of the difference in size resulting from these methods. We also estimated effect of acquisition conditions (Bragg–Brentano, parallel-beam geometry, step size, counting time) and data processing on the calculated crystallite size values. On the basis ofmore » the obtained results it is possible to conclude that direct use of the Scherrer equation, Williamson–Hall method and the Rietveld refinement employed by a series of software (EVA, PCW and TOPAS respectively) yield very close results for crystallite sizes less than 60 nm for parallel beam geometry and less than 100 nm for Bragg–Brentano geometry. However, we found that despite the fact that the differences between the crystallite sizes, which were calculated by various methods, are small by absolute values, they are statistically significant in some cases. The values of crystallite size determined from XRD were compared with those obtained by imaging in a transmission (TEM) and scanning electron microscopes (SEM). It was found that there was a good correlation in size only for crystallites smaller than 50 – 60 nm. Highlights: • The crystallite sizes for 183 nanopowders were calculated using different XRD methods • Obtained results were subject to statistical treatment • Results obtained with Bragg-Brentano and parallel beam geometries were compared • Influence of conditions of XRD pattern acquisition on results was estimated • Calculated by XRD crystallite sizes were compared with same obtained by TEM and SEM.« less

  4. Use of error grid analysis to evaluate acceptability of a point of care prothrombin time meter.

    PubMed

    Petersen, John R; Vonmarensdorf, Hans M; Weiss, Heidi L; Elghetany, M Tarek

    2010-02-01

    Statistical methods (linear regression, correlation analysis, etc.) are frequently employed in comparing methods in the central laboratory (CL). Assessing acceptability of point of care testing (POCT) equipment, however, is more difficult because statistically significant biases may not have an impact on clinical care. We showed how error grid (EG) analysis can be used to evaluate POCT PT INR with the CL. We compared results from 103 patients seen in an anti-coagulation clinic that were on Coumadin maintenance therapy using fingerstick samples for POCT (Roche CoaguChek XS and S) and citrated venous blood samples for CL (Stago STAR). To compare clinical acceptability of results we developed an EG with zones A, B, C and D. Using 2nd order polynomial equation analysis, POCT results highly correlate with the CL for CoaguChek XS (R(2)=0. 955) and CoaguChek S (R(2)=0. 93), respectively but does not indicate if POCT results are clinically interchangeable with the CL. Using EG it is readily apparent which levels can be considered clinically identical to the CL despite analytical bias. We have demonstrated the usefulness of EG in determining acceptability of POCT PT INR testing and how it can be used to determine cut-offs where differences in POCT results may impact clinical care. Copyright 2009 Elsevier B.V. All rights reserved.

  5. Impact of Excessive Weight Gain on Cardiovascular Outcomes in Type 1 Diabetes: Results From the Diabetes Control and Complications Trial/Epidemiology of Diabetes Interventions and Complications (DCCT/EDIC) Study.

    PubMed

    Purnell, Jonathan Q; Braffett, Barbara H; Zinman, Bernard; Gubitosi-Klug, Rose A; Sivitz, William; Bantle, John P; Ziegler, Georgia; Cleary, Patricia A; Brunzell, John D

    2017-12-01

    Intensive treatment (INT) of type 1 diabetes reduces the incidence of cardiovascular disease (CVD) events compared with conventional treatment (CONV), but it also results in more weight gain. Our objective was to examine whether excessive weight gain from INT of type 1 diabetes is independently associated with subsequent CVD events. Quartiles (Q) of weight gain in 1,213 participants aged 18 years and older at enrollment in the Diabetes Control and Complications Trial (DCCT) were determined within randomized treatment groups (INT vs. CONV) using change in BMI from baseline to the closeout DCCT visits. Effects of this weight gain on CVD risk factors and outcomes during an additional 20 years of observational follow-up were then determined. The Q4 INT group experienced greater proportional weight gain (median change in BMI, 6.08 kg/m 2 ), increases in CVD risk factors, and need for medications for hypertension and lipids compared with the Q1-3 INT and comparable CONV groups. Over a mean of 26 years of follow-up, the numbers of major and total CVD events were not statistically different in Q4 compared with Q1-3 of either the INT or CONV group. By year 14, however, the incident CVD event curve became significantly higher in the Q4 INT group than in the Q1-3 INT groups ( P = 0.024) and was similar to that for the CONV group. For the first 13 years after DCCT, INT for type 1 diabetes reduced macrovascular events compared with CONV, even when excessive weight gain occurred. After this, total CVD events significantly increased in the Q4 INT group, becoming equivalent to those in the CONV group. Longer follow-up is needed to determine whether this trend continues and results in more major CVD events. © 2017 by the American Diabetes Association.

  6. Phosphorus Concentrations in Stream-Water and Reference Samples - An Assessment of Laboratory Comparability

    USGS Publications Warehouse

    McHale, Michael R.; McChesney, Dennis

    2007-01-01

    In 2003, a study was conducted to evaluate the accuracy and precision of 10 laboratories that analyze water-quality samples for phosphorus concentrations in the Catskill Mountain region of New York State. Many environmental studies in this region rely on data from these different laboratories for water-quality analyses, and the data may be used in watershed modeling and management decisions. Therefore, it is important to determine whether the data reported by these laboratories are of comparable accuracy and precision. Each laboratory was sent 12 samples for triplicate analysis for total phosphorus, total dissolved phosphorus, and soluble reactive phosphorus. Eight of these laboratories reported results that met comparability criteria for all samples; the remaining two laboratories met comparability criteria for only about half of the analyses. Neither the analytical method used nor the sample concentration ranges appeared to affect the comparability of results. The laboratories whose results were comparable gave consistently comparable results throughout the concentration range analyzed, and the differences among methods did not diminish comparability. All laboratories had high data precision as indicated by sample triplicate results. In addition, the laboratories consistently reported total phosphorus values greater than total dissolved phosphorus values, and total dissolved phosphorus values greater than soluble reactive phosphorus values, as would be expected. The results of this study emphasize the importance of regular laboratory participation in sample-exchange programs.

  7. Evaluation of Landsat-4 orbit determination accuracy using batch least-squares and sequential methods

    NASA Astrophysics Data System (ADS)

    Oza, D. H.; Jones, T. L.; Feiertag, R.; Samii, M. V.; Doll, C. E.; Mistretta, G. D.; Hart, R. C.

    The Goddard Space Flight Center (GSFC) Flight Dynamics Division (FDD) commissioned Applied Technology Associates, Incorporated, to develop the Real-Time Orbit Determination/Enhanced (RTOD/E) system on a Disk Operating System (DOS)-based personal computer (PC) as a prototype system for sequential orbit determination of spacecraft. This paper presents the results of a study to compare the orbit determination accuracy for a Tracking and Data Relay Satellite (TDRS) System (TDRSS) user spacecraft, Landsat-4, obtained using RTOD/E, operating on a PC, with the accuracy of an established batch least-squares system, the Goddard Trajectory Determination System (GTDS), operating on a mainframe computer. The results of Landsat-4 orbit determination will provide useful experience for the Earth Observing System (EOS) series of satellites. The Landsat-4 ephemerides were estimated for the May 18-24, 1992, timeframe, during which intensive TDRSS tracking data for Landsat-4 were available. During this period, there were two separate orbit-adjust maneuvers on one of the TDRSS spacecraft (TDRS-East) and one small orbit-adjust maneuver for Landsat-4. Independent assessments were made of the consistencies (overlap comparisons for the batch case and covariances and the first measurement residuals for the sequential case) of solutions produced by the batch and sequential methods. The forward-filtered RTOD/E orbit solutions were compared with the definitive GTDS orbit solutions for Landsat-4; the solution differences were generally less than 30 meters after the filter had reached steady state.

  8. Getting it right by getting it wrong: When learners change languages

    PubMed Central

    Hudson Kam, Carla L.; Newport, Elissa L.

    2009-01-01

    When natural language input contains grammatical forms that are used probabilistically and inconsistently, learners will sometimes reproduce the inconsistencies; but sometimes they will instead regularize the use of these forms, introducing consistency in the language that was not present in the input. In this paper we ask what produces such regularization. We conducted three artificial language experiments, varying the use of determiners in the types of inconsistency with which they are used, and also comparing adult and child learners. In Experiment 1 we presented adult learners with scattered inconsistency – the use of multiple determiners varying in frequency in the same context – and found that adults will reproduce these inconsistencies at low levels of scatter, but at very high levels of scatter will regularize the determiner system, producing the most frequent determiner form almost all the time. In Experiment 2 we showed that this is not merely the result of frequency: when determiners are used with low frequencies but in consistent contexts, adults will learn all of the determiners veridically. In Experiment 3 we compared adult and child learners, finding that children will almost always regularize inconsistent forms, whereas adult learners will only regularize the most complex inconsistencies. Taken together, these results suggest that regularization processes in natural language learning, such as those seen in the acquisition of language from non-native speakers or in the formation of young languages, may depend crucially on the nature of language learning by young children. PMID:19324332

  9. Evaluation of Landsat-4 orbit determination accuracy using batch least-squares and sequential methods

    NASA Technical Reports Server (NTRS)

    Oza, D. H.; Jones, T. L.; Feiertag, R.; Samii, M. V.; Doll, C. E.; Mistretta, G. D.; Hart, R. C.

    1993-01-01

    The Goddard Space Flight Center (GSFC) Flight Dynamics Division (FDD) commissioned Applied Technology Associates, Incorporated, to develop the Real-Time Orbit Determination/Enhanced (RTOD/E) system on a Disk Operating System (DOS)-based personal computer (PC) as a prototype system for sequential orbit determination of spacecraft. This paper presents the results of a study to compare the orbit determination accuracy for a Tracking and Data Relay Satellite (TDRS) System (TDRSS) user spacecraft, Landsat-4, obtained using RTOD/E, operating on a PC, with the accuracy of an established batch least-squares system, the Goddard Trajectory Determination System (GTDS), operating on a mainframe computer. The results of Landsat-4 orbit determination will provide useful experience for the Earth Observing System (EOS) series of satellites. The Landsat-4 ephemerides were estimated for the May 18-24, 1992, timeframe, during which intensive TDRSS tracking data for Landsat-4 were available. During this period, there were two separate orbit-adjust maneuvers on one of the TDRSS spacecraft (TDRS-East) and one small orbit-adjust maneuver for Landsat-4. Independent assessments were made of the consistencies (overlap comparisons for the batch case and covariances and the first measurement residuals for the sequential case) of solutions produced by the batch and sequential methods. The forward-filtered RTOD/E orbit solutions were compared with the definitive GTDS orbit solutions for Landsat-4; the solution differences were generally less than 30 meters after the filter had reached steady state.

  10. Meta-analysis of Laparoscopic Versus Open Repair of Perforated Peptic Ulcer

    PubMed Central

    Antoniou, George A.; Koch, Oliver O.; Pointner, Rudolph; Granderath, Frank A.

    2013-01-01

    Background and Objectives: Laparoscopic treatment of perforated peptic ulcer (PPU) has been introduced as an alternative procedure to open surgery. It has been postulated that the minimally invasive approach involves less operative stress and results in decreased morbidity and mortality. Methods: We conducted a meta-analysis of randomized trials to test this hypothesis. Medline, EMBASE, and the Cochrane Central Register of Randomized Trials databases were searched, with no date or language restrictions. Results: Our literature search identified 4 randomized trials, with a cumulative number of 289 patients, that compared the laparoscopic approach with open sutured repair of perforated ulcer. Analysis of outcomes did not favor either approach in terms of morbidity, mortality, and reoperation rate, although odds ratios seemed to consistently support the laparoscopic approach. Results did not determine the comparative efficiency and safety of laparoscopic or open approach for PPU. Conclusion: In view of an increased interest in the laparoscopic approach, further randomized trials are considered essential to determine the relative effectiveness of laparoscopic and open repair of PPU. PMID:23743368

  11. Comparison of a specific HPLC determination of toxic aconite alkaloids in processed Radix aconiti with a titration method of total alkaloids.

    PubMed

    Csupor, Dezso; Borcsa, Botond; Heydel, Barbara; Hohmann, Judit; Zupkó, István; Ma, Yan; Widowitz, Ute; Bauer, Rudolf

    2011-10-01

    In traditional Chinese medicine, Aconitum (Ranunculaceae) roots are only applied after processing. Nevertheless, several cases of poisoning by improperly processed aconite roots have been reported. The aim of this study was to develop a reliable analytical method to assess the amount of toxic aconite alkaloids in commercial aconite roots, and to compare this method with the commonly used total alkaloid content determination by titration. The content of mesaconitine, aconitine, and hypaconitine in 16 commercial samples of processed aconite roots was determined by an HPLC method and the total alkaloid content by indirect titration. Five samples were selected for in vivo toxicological investigation. In most of the commercial samples, toxic alkaloids were not detectable, or only traces were found. In four samples, we could detect >0.04% toxic aconite alkaloids, the highest with a content of 0.16%. The results of HPLC analysis were compared with the results obtained by titration, and no correlation was found between the two methods. The in vivo results reassured the validity of the HPLC determination. Samples with mesaconitine, aconitine, and hypaconitine content below the HPLC detection limit still contained up to 0.2% alkaloids determined by titration. Since titration of alkaloids gives no information selectively on the aconitine-type alkaloid content and toxicity of aconite roots this method is not appropriate for safety assessment. The HPLC method developed by us provides a quick and reliable assessment of toxicity and should be considered as a purity test in pharmacopoeia monographs.

  12. Dynamic calibration of a wheelchair dynamometer.

    PubMed

    DiGiovine, C P; Cooper, R A; Boninger, M L

    2001-01-01

    The inertia and resistance of a wheelchair dynamometer must be determined in order to compare the results of one study to another, independent of the type of device used. The purpose of this study was to describe and implement a dynamic calibration test for characterizing the electro-mechanical properties of a dynamometer. The inertia, the viscous friction, the kinetic friction, the motor back-electromotive force constant, and the motor constant were calculated using three different methods. The methodology based on a dynamic calibration test along with a nonlinear regression analysis produced the best results. The coefficient of determination comparing the dynamometer model output to the measured angular velocity and torque was 0.999 for a ramp input and 0.989 for a sinusoidal input. The inertia and resistance were determined for the rollers and the wheelchair wheels. The calculation of the electro-mechanical parameters allows for the complete description of the propulsive torque produced by an individual, given only the angular velocity and acceleration. The measurement of the electro-mechanical properties of the dynamometer as well as the wheelchair/human system provides the information necessary to simulate real-world conditions.

  13. Comparison of a Novel Multiple Marker Assay Versus the Risk of Malignancy Index for the Prediction of Epithelial Ovarian Cancer in Patients with a Pelvic Mass

    PubMed Central

    MOORE, Richard G.; JABRE-RAUGHLEY, Moune; BROWN, Amy K.; ROBISON, Katina M.; MILLER, M. Craig; ALLARD, W. Jeffery; KURMAN, Robert J.; BAST, Robert C.; SKATES, Steven J.

    2012-01-01

    Objectives To compare the Risk of Malignancy Index (RMI) to the Risk of Ovarian Malignancy Algorithm (ROMA) to predict EOC in women with a pelvic mass. Study Design 457 women with imaging results from ultrasound, CT and MRI, and serum HE4 and CA 125 determined prior to surgery for pelvic mass were evaluable. RMI values were determined using CA 125, imaging score and menopausal status. ROMA values were determined using HE4, CA 125, and menopausal status. Results At a set specificity of 75%, ROMA had a sensitivity of 94.3% and RMI had a sensitivity of 84.6% for distinguishing benign from EOC (p=0.0029). In patients with stage I and II disease, ROMA achieved a sensitivity of 85.3% compared with 64.7% for RMI (p<0.0001). Conclusions The dual marker algorithm utilizing HE4 and CA125 to calculate a ROMA value achieves a significantly higher sensitivity for identifying women with EOC than does RMI. PMID:20471625

  14. Comparing State and District Test Results to National Norms: Interpretations of Scoring "Above the National Average."

    ERIC Educational Resources Information Center

    Linn, Robert L.; And Others

    Norm-referenced test results reported by states and school districts and factors related to those scores were studied through mail and telephone surveys of 35 states and a nationally representative sample of 153 school districts to determine the degree to which "above average" results were being reported. Part of the stimulus for this…

  15. Analysis of methods to determine storage capacity of, and sedimentation in, Loch Lomond Reservoir, Santa Cruz County, California, 2009

    USGS Publications Warehouse

    McPherson, Kelly R.; Freeman, Lawrence A.; Flint, Lorraine E.

    2011-01-01

    In 2009, the U.S. Geological Survey, in cooperation with the City of Santa Cruz, conducted bathymetric and topographic surveys to determine the water storage capacity of, and the loss of capacity owing to sedimentation in, Loch Lomond Reservoir in Santa Cruz County, California. The topographic survey was done as a supplement to the bathymetric survey to obtain information about temporal changes in the upper reach of the reservoir where the water is shallow or the reservoir may be dry, as well as to obtain information about shoreline changes throughout the reservoir. Results of a combined bathymetric and topographic survey using a new, state-of-the-art method with advanced instrument technology indicate that the maximum storage capacity of the reservoir at the spillway altitude of 577.5 feet (National Geodetic Vertical Datum of 1929) was 8,646 ±85 acre-feet in March 2009, with a confidence level of 99 percent. This new method is a combination of bathymetric scanning using multibeam-sidescan sonar, and topographic surveying using laser scanning (LiDAR), which produced a 1.64-foot-resolution grid with altitudes to 0.3-foot resolution and an estimate of total water storage capacity at a 99-percent confidence level. Because the volume of sedimentation in a reservoir is considered equal to the decrease in water-storage capacity, sedimentation in Loch Lomond Reservoir was determined by estimating the change in storage capacity by comparing the reservoir bed surface defined in the March 2009 survey with a revision of the reservoir bed surface determined in a previous investigation in November 1998. This revised reservoir-bed surface was defined by combining altitude data from the 1998 survey with new data collected during the current (2009) investigation to fill gaps in the 1998 data. Limitations that determine the accuracy of estimates of changes in the volume of sedimentation from that estimated in each of the four previous investigations (1960, 1971, 1982, and 1998) are a result of the limitations of the survey equipment and data-processing methods used. Previously used and new methods were compared to determine the recent (1998-2009) change in storage capacity and the most accurate and cost-effective means to define the reservoir bed surface so that results can be easily replicated in future surveys. Results of this investigation indicate that the advanced method used in the 2009 survey accurately captures the features of the wetted reservoir surface as well as features along the shoreline that affect the storage capacity calculations. Because the bathymetric and topographic data are referenced to a datum, the results can be easily replicated or compared with future results. Comparison of the 2009 reservoir-bed surface with the surface defined in 1998 indicates that sedimentation is occurring throughout the reservoir. About 320 acre-feet of sedimentation has occurred since 1998, as determined by comparing the revised 1998 reservoir-bed surface, with an associated maximum reservoir storage capacity of 8,965 acre-feet, to the 2009 reservoir bed surface, with an associated maximum capacity of 8,646 acre-feet. This sedimentation is more than 3 percent of the total storage capacity that was calculated on the basis of the results of the 1998 bathymetric investigation.

  16. Direct quantification of molar masses of copolymers by online liquid chromatography under critical conditions-nuclear magnetic resonance and size exclusion chromatography-nuclear magnetic resonance.

    PubMed

    Hehn, Mathias; Wagner, Thomas; Hiller, Wolf

    2014-01-07

    Online LCCC-NMR and SEC-NMR are compared regarding the determination of molar masses of block copolymers. Two different direct referencing methods are particularly demonstrated in LCCC-NMR for a detailed characterization of diblock copolymers and their co-monomers. First, an intramolecular reference group was used for the direct determination of block lengths and molar masses. For the first time, it was shown that LCCC-NMR can be used for an accurate determination of Mw and Mn of copolymers. These data were in perfect agreement with SEC-NMR measurements using the same intramolecular referencing method. In contrast, the determination of molar masses with common relative methods based on calibrations with homopolymers delivered inaccurate results for all investigated diblock copolymers due to different hydrodynamic volumes of the diblock copolymer compared to their homopolymers. The intramolecular referencing method provided detailed insights in the co-monomer behavior during the chromatographic separation of LCCC. Especially, accurate chain lengths and chemical compositions of the "invisible" and "visible" blocks were quantified during the elution under critical conditions and provided new aspects to the concept of critical conditions. Second, an external reference NMR signal was used to directly determine concentrations and molar masses of the block copolymers from the chromatographic elution profile. Consequently, the intensity axes of the resulting chromatograms were converted to molar amounts and masses, allowing for determination of the amount of polymer chains with respect to elution volume, the evaluation of the limiting magnitude of concentration for LCCC-NMR, and determination of the molar masses of copolymers.

  17. 13C tracer experiments and metabolite balancing for metabolic flux analysis: comparing two approaches

    PubMed

    Schmidt; Marx; de Graaf AA; Wiechert; Sahm; Nielsen; Villadsen

    1998-04-05

    Conventional metabolic flux analysis uses the information gained from determination of measurable fluxes and a steady-state assumption for intracellular metabolites to calculate the metabolic fluxes in a given metabolic network. The determination of intracellular fluxes depends heavily on the correctness of the assumed stoichiometry including the presence of all reactions with a noticeable impact on the model metabolite balances. Determination of fluxes in complex metabolic networks often requires the inclusion of NADH and NADPH balances, which are subject to controversial debate. Transhydrogenation reactions that transfer reduction equivalents from NADH to NADPH or vice versa can usually not be included in the stoichiometric model, because they result in singularities in the stoichiometric matrix. However, it is the NADPH balance that, to a large extent, determines the calculated flux through the pentose phosphate pathway. Hence, wrong assumptions on the presence or activity of transhydrogenation reactions will result in wrong estimations of the intracellular flux distribution. Using 13C tracer experiments and NMR analysis, flux analysis can be performed on the basis of only well established stoichiometric equations and measurements of the labeling state of intracellular metabolites. Neither NADH/NADPH balancing nor assumptions on energy yields need to be included to determine the intracellular fluxes. Because metabolite balancing methods and the use of 13C labeling measurements are two different approaches to the determination of intracellular fluxes, both methods can be used to verify each other or to discuss the origin and significance of deviations in the results. Flux analysis based entirely on metabolite balancing and flux analysis, including labeling information, have been performed independently for a wild-type strain of Aspergillus oryzae producing alpha-amylase. Two different nitrogen sources, NH4+ and NO3-, have been used to investigate the influence of the NADPH requirements on the intracellular flux distribution. The two different approaches to the calculation of fluxes are compared and deviations in the results are discussed. Copyright 1998 John Wiley & Sons, Inc.

  18. A FEM-based method to determine the complex material properties of piezoelectric disks.

    PubMed

    Pérez, N; Carbonari, R C; Andrade, M A B; Buiochi, F; Adamowski, J C

    2014-08-01

    Numerical simulations allow modeling piezoelectric devices and ultrasonic transducers. However, the accuracy in the results is limited by the precise knowledge of the elastic, dielectric and piezoelectric properties of the piezoelectric material. To introduce the energy losses, these properties can be represented by complex numbers, where the real part of the model essentially determines the resonance frequencies and the imaginary part determines the amplitude of each resonant mode. In this work, a method based on the Finite Element Method (FEM) is modified to obtain the imaginary material properties of piezoelectric disks. The material properties are determined from the electrical impedance curve of the disk, which is measured by an impedance analyzer. The method consists in obtaining the material properties that minimize the error between experimental and numerical impedance curves over a wide range of frequencies. The proposed methodology starts with a sensitivity analysis of each parameter, determining the influence of each parameter over a set of resonant modes. Sensitivity results are used to implement a preliminary algorithm approaching the solution in order to avoid the search to be trapped into a local minimum. The method is applied to determine the material properties of a Pz27 disk sample from Ferroperm. The obtained properties are used to calculate the electrical impedance curve of the disk with a Finite Element algorithm, which is compared with the experimental electrical impedance curve. Additionally, the results were validated by comparing the numerical displacement profile with the displacements measured by a laser Doppler vibrometer. The comparison between the numerical and experimental results shows excellent agreement for both electrical impedance curve and for the displacement profile over the disk surface. The agreement between numerical and experimental displacement profiles shows that, although only the electrical impedance curve is considered in the adjustment procedure, the obtained material properties allow simulating the displacement amplitude accurately. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Mean centering of ratio spectra and concentration augmented classical least squares in a comparative approach for quantitation of spectrally overlapped bands of antihypertensives in formulations

    NASA Astrophysics Data System (ADS)

    Hegazy, Maha Abdel Monem; Fayez, Yasmin Mohammed

    2015-04-01

    Two different methods manipulating spectrophotometric data have been developed, validated and compared. One is capable of removing the signal of any interfering components at the selected wavelength of the component of interest (univariate). The other includes more variables and extracts maximum information to determine the component of interest in the presence of other components (multivariate). The applied methods are smart, simple, accurate, sensitive, precise and capable of determination of spectrally overlapped antihypertensives; hydrochlorothiazide (HCT), irbesartan (IRB) and candesartan (CAN). Mean centering of ratio spectra (MCR) and concentration residual augmented classical least-squares method (CRACLS) were developed and their efficiency was compared. CRACLS is a simple method that is capable of extracting the pure spectral profiles of each component in a mixture. Correlation was calculated between the estimated and pure spectra and was found to be 0.9998, 0.9987 and 0.9992 for HCT, IRB and CAN, respectively. The methods were successfully determined the three components in bulk powder, laboratory-prepared mixtures, and combined dosage forms. The results obtained were compared statistically with each other and to those of the official methods.

  20. Selecting Value-Added Models for Postsecondary Institutional Assessment

    ERIC Educational Resources Information Center

    Steedle, Jeffrey T.

    2012-01-01

    Value-added scores from tests of college learning indicate how score gains compare to those expected from students of similar entering academic ability. Unfortunately, the choice of value-added model can impact results, and this makes it difficult to determine which results to trust. The research presented here demonstrates how value-added models…

  1. Conceptual design study of a 1985 commercial STOL tilt rotor transport

    NASA Technical Reports Server (NTRS)

    Widdison, C. A.; Magee, J. P.; Alexander, H. R.

    1974-01-01

    Results of conceptual engineering design studies of a STOL tilt rotor commercial aircraft for the 1985 time frame are presented. The details of aircraft size, performance, flying qualities, noise, and cost are included. The savings in terms of fuel economy resulting from STOL operations compared with VTOL vehicles are determined.

  2. Evaluating ADS, ISI Web of Knowledge and Scopus in the Context of Two Astronomy Libraries in Spain

    NASA Astrophysics Data System (ADS)

    Gomez, M.; Merida Martín, F.

    2007-10-01

    We present the results of a comparative analysis of ADS, ISI Web of Knowledge and Scopus in the context of two astronomical libraries as well as the results of a patron survey conducted to determine how patrons use these services to get the information they need.

  3. Your Chi-Square Test Is Statistically Significant: Now What?

    ERIC Educational Resources Information Center

    Sharpe, Donald

    2015-01-01

    Applied researchers have employed chi-square tests for more than one hundred years. This paper addresses the question of how one should follow a statistically significant chi-square test result in order to determine the source of that result. Four approaches were evaluated: calculating residuals, comparing cells, ransacking, and partitioning. Data…

  4. Comparison of methods applied in photoinduced transient spectroscopy to determining the defect center parameters: The correlation procedure and the signal analysis based on inverse Laplace transformation

    NASA Astrophysics Data System (ADS)

    Suproniuk, M.; Pawłowski, M.; Wierzbowski, M.; Majda-Zdancewicz, E.; Pawłowski, Ma.

    2018-04-01

    The procedure for determination of trap parameters by photo-induced transient spectroscopy is based on the Arrhenius plot that illustrates a thermal dependence of the emission rate. In this paper, we show that the Arrhenius plot obtained by the correlation method is shifted toward lower temperatures as compared to the one obtained with the inverse Laplace transformation. This shift is caused by the model adequacy error of the correlation method and introduces errors to a calculation procedure of defect center parameters. The effect is exemplified by comparing the results of the determination of trap parameters with both methods based on photocurrent transients for defect centers observed in tin-doped neutron-irradiated silicon crystals and in gallium arsenide grown with the Vertical Gradient Freeze method.

  5. Experimental Study of Thermophysical Properties of Peat Fuel

    NASA Astrophysics Data System (ADS)

    Mikhailov, A. S.; Piralishvili, Sh. A.; Stepanov, E. G.; Spesivtseva, N. S.

    2017-03-01

    A study has been made of thermophysical properties of peat pellets of higher-than-average reactivity due to the pretreatment of the raw material. A synchronous differential analysis of the produced pellets was performed to determine the gaseous products of their decomposition by the mass-spectroscopy method. The parameters of the mass loss rate, the heat-release function, the activation energy, the rate constant of the combustion reaction, and the volatile yield were compared to the properties of pellets compressed by the traditional method on a matrix pelletizer. It has been determined that as a result of the peat pretreatment, the yield of volatile components increases and the activation energy of the combustion reaction decreases by 17 and 30% respectively compared with the raw fuel. This determines its prospects for burning in an atomized state at coal-fired thermal electric power plants.

  6. Prediction of dynamic and aerodynamic characteristics of the centrifugal fan with forward curved blades

    NASA Astrophysics Data System (ADS)

    Polanský, Jiří; Kalmár, László; Gášpár, Roman

    2013-12-01

    The main aim of this paper is determine the centrifugal fan with forward curved blades aerodynamic characteristics based on numerical modeling. Three variants of geometry were investigated. The first, basic "A" variant contains 12 blades. The geometry of second "B" variant contains 12 blades and 12 semi-blades with optimal length [1]. The third, control variant "C" contains 24 blades without semi-blades. Numerical calculations were performed by CFD Ansys. Another aim of this paper is to compare results of the numerical simulation with results of approximate numerical procedure. Applied approximate numerical procedure [2] is designated to determine characteristics of the turbulent flow in the bladed space of a centrifugal-flow fan impeller. This numerical method is an extension of the hydro-dynamical cascade theory for incompressible and inviscid fluid flow. Paper also partially compares results from the numerical simulation and results from the experimental investigation. Acoustic phenomena observed during experiment, during numerical simulation manifested as deterioration of the calculation stability, residuals oscillation and thus also as a flow field oscillation. Pressure pulsations are evaluated by using frequency analysis for each variant and working condition.

  7. Performance and Self-Consistency of the Generalized Dielectric Dependent Hybrid Functional

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brawand, Nicholas P.; Govoni, Marco; Vörös, Márton

    Here, we analyze the performance of the recently proposed screened exchange constant functional (SX) on the GW100 test set, and we discuss results obtained at different levels of self-consistency. The SX functional is a generalization of dielectric dependent hybrid functionals to finite systems; it is nonempirical and depends on the average screening of the exchange interaction. We compare results for ionization potentials obtained with SX to those of CCSD(T) calculations and experiments, and we find excellent agreement, on par with recent state of the art methods based on many body perturbation theory. Applying SX perturbatively to correct PBE eigenvalues yieldsmore » improved results in most cases, except for ionic molecules, for which wave function self-consistency is instead crucial. Calculations where wave functions and the screened exchange constant (α SX) are determined self-consistently, and those where α SX is fixed to the value determined within PBE, yield results of comparable accuracy. Perturbative G 0W 0 corrections of eigenvalues obtained with self-consistent αSX are small on average, for all molecules in the GW100 test set.« less

  8. Performance and Self-Consistency of the Generalized Dielectric Dependent Hybrid Functional

    DOE PAGES

    Brawand, Nicholas P.; Govoni, Marco; Vörös, Márton; ...

    2017-05-24

    Here, we analyze the performance of the recently proposed screened exchange constant functional (SX) on the GW100 test set, and we discuss results obtained at different levels of self-consistency. The SX functional is a generalization of dielectric dependent hybrid functionals to finite systems; it is nonempirical and depends on the average screening of the exchange interaction. We compare results for ionization potentials obtained with SX to those of CCSD(T) calculations and experiments, and we find excellent agreement, on par with recent state of the art methods based on many body perturbation theory. Applying SX perturbatively to correct PBE eigenvalues yieldsmore » improved results in most cases, except for ionic molecules, for which wave function self-consistency is instead crucial. Calculations where wave functions and the screened exchange constant (α SX) are determined self-consistently, and those where α SX is fixed to the value determined within PBE, yield results of comparable accuracy. Perturbative G 0W 0 corrections of eigenvalues obtained with self-consistent αSX are small on average, for all molecules in the GW100 test set.« less

  9. Comparative study on the nutritional and antioxidant properties of two Mexican corn (Zea mays) based meals versus processed cereals.

    PubMed

    Sánchez-Herrera, Marissa; Martínez-Cano, Evelia; Maldonado-Santoyo, María; Aparicio-Fernández, Xochitl

    2014-06-01

    The present study was conducted to analyze the chemical composition, total phenolics content and antioxidant capacity of two whole corn (Zea mays) based meals traditional from Mexico: "traditional pinole" and "seven grain pinole"; and compare it with information available from ready to eat cereal products based on refined corn and whole grain cereals. Proximate analyses (moisture, ash, fat, protein and fiber) were carried out according to the procedures of AOAC, sugars content was determined by HPLC method; calcium and iron were quantified using atomic absorption spectroscopy. Total phenolic compounds were determined by Folin-Ciocalteu spectrophotometric method; the antiradical capacity was determined by DPPH colorimetric method and total antioxidant capacity was determined by FRAP method. Traditional and seven grain pinole presented higher energy content and nutrient density (protein and fat) than processed cereals. Calcium content was higher in processed cereals than pinole; seven grain pinole presented the highest conentration of iron. Polyphenolic concentration was higher in both kinds of pinole compared to processed cereals; traditional pinole presented the highest antioxidant activity measured by DPPH and FRAP methods. The results provide evidence about the important nutrient and antioxidant content of traditional and seven grain pinole compared to processed cereals based on corn and other grains. It is recommended their incorporation in to regular diet as a healthy food, with a good protein level, low sugar content and good antioxidant capacity.

  10. Evaluation of two portable meters for determination of blood triglyceride concentration in dogs.

    PubMed

    Kluger, Elissa K; Dhand, Navneet K; Malik, Richard; Ilkin, William J; Snow, David H; Govendir, Merran

    2010-02-01

    To evaluate agreement between 2 portable triglyceride meters and a veterinary laboratory for measurement of blood triglyceride concentrations in dogs and evaluate effects of Hct and blood volume analyzed. 97 blood samples collected from 60 dogs. Triglyceride concentrations were measured in blood by use of 2 meters and compared with serum triglyceride concentrations determined by a veterinary laboratory. Within- and between-day precision, accuracy, and effects of blood volume and Hct were analyzed. Accuracy of both meters varied with triglyceride concentration, although both accurately delineated dogs with triglyceride concentrations < 180 mg/dL versus > or = 180 mg/dL. One meter had results with excellent overall correlation with results of the standard laboratory method, with a concordance correlation coefficient of 0.94 and mean difference of 20.3 mg/dL. The other meter had a good overall concordance correlation coefficient of 0.86 with a higher absolute mean difference of -27.7 mg/dL. Results were only affected by blood volume; triglyceride concentrations determined via both meters were significantly lower when 7 microL of EDTA-anticoagulated blood was used, compared with larger volumes. 1 meter had greater accuracy in the range of 140 to 400 mg/dL and was therefore well suited to detect hypertriglyceridemia. The other meter was accurate with triglyceride values < 140 mg/dL and yielded results similar to those of the veterinary laboratory in the range of 140 to 400 mg/dL, therefore being suitable for determination of triglyceride concentrations in nonfed dogs and dogs with mildly high concentrations.

  11. Independent Orbiter Assessment (IOA): Assessment of the backup flight system FMEA/CIL

    NASA Technical Reports Server (NTRS)

    Prust, E. E.; Ewell, J. J., Jr.; Hinsdale, L. W.

    1988-01-01

    The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA effort first completed an analysis of the Backup Flight System (BFS) hardware, generating draft failure modes and Potential Critical Items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. The IOA results were then compared to the proposed NASA Post 51-L FMEA/CIL baseline. A resolution of each discrepancy from the comparison is provided through additional analysis as required. This report documents the results of that comparison for the Orbiter BFS hardware. The IOA product for the BFS analysis consisted of 29 failure mode worksheets that resulted in 21 Potential Critical Items (PCI) being identified. This product was originally compared with the proposed NASA BFS baseline and subsequently compared with the applicable Data Processing System (DPS), Electrical Power Distribution and Control (EPD and C), and Displays and Controls NASA CIL items. The comparisons determined if there were any results which had been found by the IOA but were not in the NASA baseline. The original assessment determined there were numerous failure modes and potential critical items in the IOA analysis that were not contained in the NASA BFS baseline. Conversely, the NASA baseline contained three FMEAs (IMU, ADTA, and Air Data Probe) for CIL items that were not identified in the IOA product.

  12. Choosing HIV Counseling and Testing Strategies for Outreach Settings: A Randomized Trial.

    PubMed

    Spielberg, Freya; Branson, Bernard M; Goldbaum, Gary M; Lockhart, David; Kurth, Ann; Rossini, Anthony; Wood, Robert W

    2005-03-01

    In surveys, clients have expressed preferences for alternatives to traditional HIV counseling and testing. Few data exist to document how offering such alternatives affects acceptance of HIV testing and receipt of test results. This randomized controlled trial compared types of HIV tests and counseling at a needle exchange and 2 bathhouses to determine which types most effectively ensured that clients received test results. Four alternatives were offered on randomly determined days: (1) traditional test with standard counseling, (2) rapid test with standard counseling, (3) oral fluid test with standard counseling, and (4) traditional test with choice of written pretest materials or standard counseling. Of 17,010 clients offered testing, 7014 (41%) were eligible; of those eligible, 761 (11%) were tested: 324 at the needle exchange and 437 at the bathhouses. At the needle exchange, more clients accepted testing (odds ratio [OR] = 2.3; P < 0.001) and received results (OR = 2.6; P < 0.001) on days when the oral fluid test was offered compared with the traditional test. At the bathhouses, more clients accepted oral fluid testing (OR = 1.6; P < 0.001), but more clients overall received results on days when the rapid test was offered (OR = 1.9; P = 0.01). Oral fluid testing and rapid blood testing at both outreach venues resulted in significantly more people receiving test results compared with traditional HIV testing. Making counseling optional increased testing at the needle exchange but not at the bathhouses.

  13. Stability of outer planetary orbits around binary stars - A comparison of Hill's and Laplace's stability criteria

    NASA Technical Reports Server (NTRS)

    Kubala, A.; Black, D.; Szebehely, V.

    1993-01-01

    A comparison is made between the stability criteria of Hill and that of Laplace to determine the stability of outer planetary orbits encircling binary stars. The restricted, analytically determined results of Hill's method by Szebehely and coworkers and the general, numerically integrated results of Laplace's method by Graziani and Black (1981) are compared for varying values of the mass parameter mu. For mu = 0 to 0.15, the closest orbit (lower limit of radius) an outer planet in a binary system can have and still remain stable is determined by Hill's stability criterion. For mu greater than 0.15, the critical radius is determined by Laplace's stability criterion. It appears that the Graziani-Black stability criterion describes the critical orbit within a few percent for all values of mu.

  14. Comparison of platelet function and viscoelastic test results between healthy dogs and dogs with naturally occurring chronic kidney disease.

    PubMed

    Dudley, Alicia; Byron, Julie K; Burkhard, Mary Jo; Warry, Emma; Guillaumin, Julien

    2017-05-01

    OBJECTIVE To compare platelet function and viscoelastic test results between healthy dogs and dogs with chronic kidney disease (CKD) to assess whether dogs with CKD have platelet dysfunction and altered blood coagulation. ANIMALS 10 healthy control dogs and 11 dogs with naturally occurring CKD. PROCEDURES Blood and urine were collected once from each dog for a CBC, serum biochemical analysis, urinalysis, and determination of the urine protein-to-creatinine ratio, prothrombin time, activated partial thromboplastin time, plasma fibrinogen concentration, and antithrombin activity. Closure time was determined by use of a platelet function analyzer and a collagen-ADP platelet agonist. Thromboelastography (TEG) variables (reaction time, clotting time, α angle, maximum amplitude, and global clot strength [G value]) were determined by use of recalcified nonactivated TEG. Platelet expression of glycoprotein Ib (GPIb; receptor for von Willebrand factor), integrin αIIbβ3 (αIIbβ3; receptor for fibrinogen), and P-selectin (marker for platelet activation) was assessed by flow cytometry. RESULTS Compared with healthy control dogs, the median closure time was prolonged, the median maximum amplitude and G value were increased, and the median clotting time was decreased for dogs with CKD. Platelet expression of both αIIbβ3 and P-selectin was also significantly increased for dogs with CKD, compared with that for control dogs. Platelet expression of GPIb, αIIbβ3, and P-selectin was not correlated with closure time or any TEG variable. CONCLUSIONS AND CLINICAL RELEVANCE Results indicated that dogs with CKD frequently had evidence of platelet dysfunction and hypercoagulability that were not totally attributable to alterations in platelet surface expression of GPIb, αIIbβ3, and P-selectin.

  15. Consumer vinegar test for determining calcium disintegration.

    PubMed

    Mason, N A; Patel, J D; Dressman, J B; Shimp, L A

    1992-09-01

    A consumer test and standardized methods were compared for measuring the disintegration of calcium tablets, and the disintegration results were compared with results of dissolution testing to determine the ability of the consumer test of disintegration to predict bioavailability of calcium. Disintegration of 17 calcium supplement products, in tablet form, was studied in Simulated Gastric Fluid Test Solution, USP, without pepsin (GF), in distilled water, and in white distilled vinegar. For disintegration testing with GF and with distilled water, six tablets of each product were placed in an apparatus and immersed in the solution at 37 degrees C for 60 minutes. Six tablets of each product were tested in 200 mL of vinegar at room temperature for 30 minutes. Disintegration was determined by visual observation. Seven products were tested for dissolution in GF or water. Three samples of each product were tested at intervals over 120 minutes for calcium content. Results of testing with an ion-selective electrode were converted to milligrams and compared with the calcium content of the tablets (as claimed on the package label). The mean disintegration times of various calcium products in vinegar ranged from 1.8 to greater than 30 minutes. The mean time in distilled water and GF ranged from 1.6 to greater than 60 minutes and from 1.0 to greater than 60 minutes, respectively. Results were in agreement in 87% to 93% of cases between the consumer vinegar test and the standardized disintegration test methods, a significant correlation. No correlation was found between disintegration time and the extent of dissolution. The disintegration and dissolution of commercially available calcium tablets was highly variable.(ABSTRACT TRUNCATED AT 250 WORDS)

  16. Hemostatic findings of pleural fluid in dogs and the association between pleural effusions and primary hyperfibrino(geno)lysis: A cohort study of 99 dogs

    PubMed Central

    Drigo, Michele; Piek, Christine J.; Simioni, Paolo; Caldin, Marco

    2018-01-01

    The primary objective of this study was to determine if activation of coagulation and fibrinolysis occurs in canine pleural effusions. Thirty-three dogs with pleural effusions of different origin were studied. Pleural effusion fibrinogen concentrations were significantly lower, while pleural fibrin-fibrinogen degradation products (FDPs) and D-dimer concentrations were significantly higher than those in plasma (P < 0.001 for all comparisons). These results show that, in canine pleural fluids, there is evidence of coagulation activation and fibrinolysis. The secondary aims of the current study were to determine if primary hyperfibrinolysis ([PHF] i.e., elevated plasma FDPs with a normal D-dimer concentrations), occurs in dogs with pleural effusion, and whether the presence of a concurrent inflammatory process may have activated the hemostatic cascade, with its intrinsically linked secondary hyperfibrinolysis, masking the concurrent PHF. The previously 33 selected dogs with pleural effusion (group 1) were compared to two control groups of 33 healthy (group 2) and 33 sick dogs without pleural effusion (group 3). Serum fibrinogen, FDPs, D-dimer, C-reactive protein (CRP), fibrinogen/CRP ratio, and frequency of PHF were determined. Fibrinogen, FDPs, D-dimer and CRP concentrations in group 1 were significantly increased compared to group 2 (P < 0.001 for all comparisons). FDPs and CRP concentrations in group 1 were also significantly increased compared to group 3 (P = 0.001 and P < 0.001, respectively). The fibrinogen/CRP ratio was significantly decreased in group 1 compared to groups 2 and 3 (P < 0.001 for both comparison). The frequency of PHF was significantly higher in group 1 compared to groups 2 (P = 0.004), but not compared to group 3. These results support the hypothesis that PHF occurs significantly more often in dogs with pleural effusion compared to healthy dogs. Nevertheless, the decrease in the fibrinogen/CRP ratio in group 1 compared to group 3, considering the higher FDPs and similar D-dimer concentrations, would suggest that PHF is also more frequent in dogs with pleural effusion compared to sick control dogs, and that this phenomenon is hidden due to concurrent secondary hyperfibrinolysis. PMID:29462172

  17. Hemostatic findings of pleural fluid in dogs and the association between pleural effusions and primary hyperfibrino(geno)lysis: A cohort study of 99 dogs.

    PubMed

    Zoia, Andrea; Drigo, Michele; Piek, Christine J; Simioni, Paolo; Caldin, Marco

    2018-01-01

    The primary objective of this study was to determine if activation of coagulation and fibrinolysis occurs in canine pleural effusions. Thirty-three dogs with pleural effusions of different origin were studied. Pleural effusion fibrinogen concentrations were significantly lower, while pleural fibrin-fibrinogen degradation products (FDPs) and D-dimer concentrations were significantly higher than those in plasma (P < 0.001 for all comparisons). These results show that, in canine pleural fluids, there is evidence of coagulation activation and fibrinolysis. The secondary aims of the current study were to determine if primary hyperfibrinolysis ([PHF] i.e., elevated plasma FDPs with a normal D-dimer concentrations), occurs in dogs with pleural effusion, and whether the presence of a concurrent inflammatory process may have activated the hemostatic cascade, with its intrinsically linked secondary hyperfibrinolysis, masking the concurrent PHF. The previously 33 selected dogs with pleural effusion (group 1) were compared to two control groups of 33 healthy (group 2) and 33 sick dogs without pleural effusion (group 3). Serum fibrinogen, FDPs, D-dimer, C-reactive protein (CRP), fibrinogen/CRP ratio, and frequency of PHF were determined. Fibrinogen, FDPs, D-dimer and CRP concentrations in group 1 were significantly increased compared to group 2 (P < 0.001 for all comparisons). FDPs and CRP concentrations in group 1 were also significantly increased compared to group 3 (P = 0.001 and P < 0.001, respectively). The fibrinogen/CRP ratio was significantly decreased in group 1 compared to groups 2 and 3 (P < 0.001 for both comparison). The frequency of PHF was significantly higher in group 1 compared to groups 2 (P = 0.004), but not compared to group 3. These results support the hypothesis that PHF occurs significantly more often in dogs with pleural effusion compared to healthy dogs. Nevertheless, the decrease in the fibrinogen/CRP ratio in group 1 compared to group 3, considering the higher FDPs and similar D-dimer concentrations, would suggest that PHF is also more frequent in dogs with pleural effusion compared to sick control dogs, and that this phenomenon is hidden due to concurrent secondary hyperfibrinolysis.

  18. Comparison of modal analysis results of laser vibrometry and nearfield acoustical holography measurements of an aluminum plate

    NASA Astrophysics Data System (ADS)

    Potter, Jennifer L.

    2011-12-01

    Noise and vibration has long been sought to be reduced in major industries: automotive, aerospace and marine to name a few. Products must be tested and pass certain levels of federally regulated standards before entering the market. Vibration measurements are commonly acquired using accelerometers; however limitations of this method create a need for alternative solutions. Two methods for non-contact vibration measurements are compared: Laser Vibrometry, which directly measures the surface velocity of the aluminum plate, and Nearfield Acoustic Holography (NAH), which measures sound pressure in the nearfield, and using Green's Functions, reconstructs the surface velocity at the plate. The surface velocity from each method is then used in modal analysis to determine the comparability of frequency, damping and mode shapes. Frequency and mode shapes are also compared to an FEA model. Laser Vibrometry is a proven, direct method for determining surface velocity and subsequently calculating modal analysis results. NAH is an effective method in locating noise sources, especially those that are not well separated spatially. Little work has been done in incorporating NAH into modal analysis.

  19. A physical model study of scattering of waves by aligned cracks: Comparison between experiment and theory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ass'ad, J.M.; McDonald, J.A.; Kusky, T.M.

    1993-04-01

    An approximation to plane-wave propagation through a composite material is examined using a physical model with oriented but randomly distributed penny-shaped rubber inclusions within an isotropic epoxy resin matrix. A pulse transmission method is used to determine velocities of shear and compressional waves as a function of angle of incidence and crack density. The experimental and theoretical results of Hudson were compared and limitations within the crack parameters used in this study have been determined. Results from both polarized shear waves (S1, S2) compare favorably with the theory for a composite with up to 7% crack density, but theory andmore » experiment diverge at higher crack densities. On the other hand, compressional-wave velocities at low crack densities (1% and 3%) compare favorably with the theory. It is also shown that the velocity ratio V[sub p]/V[sub s] for two extreme cases, i.e. propagation normal and parallel to the cracks, as a function of crack density and porosity, has a strong directional dependence.« less

  20. Stress concentration investigations using NASTRAN

    NASA Technical Reports Server (NTRS)

    Gillcrist, M. C.; Parnell, L. A.

    1986-01-01

    Parametic investigations are performed using several two dimensional finite element formulations to determine their suitability for use in predicting extremum stresses in marine propellers. Comparisons are made of two NASTRAN elements (CTRIM6 and CTRAIA2) wherein elasticity properties have been modified to yield plane strain results. The accuracy of the elements is investigated by comparing finite element stress predictions with experimentally determined stresses in two classical cases: (1) tension in a flat plate with a circular hole; and (2) a filleted flat bar subjected to in-plane bending. The CTRIA2 element is found to provide good results. The displacement field from a three dimensional finite element model of a representative marine propeller is used as the boundary condition for the two dimensional plane strain investigations of stresses in the propeller blade and fillet. Stress predictions from the three dimensional analysis are compared with those from the two dimensional models. The validity of the plane strain modifications to the NASTRAN element is checked by comparing the modified CTRIA2 element stress predictions with those of the ABAQUS plane strain element, CPE4.

  1. Experience Gained From Launch and Early Orbit Support of the Rossi X-Ray Timing Explorer (RXTE)

    NASA Technical Reports Server (NTRS)

    Fink, D. R.; Chapman, K. B.; Davis, W. S.; Hashmall, J. A.; Shulman, S. E.; Underwood, S. C.; Zsoldos, J. M.; Harman, R. R.

    1996-01-01

    this paper reports the results to date of early mission support provided by the personnel of the Goddard Space Flight Center Flight Dynamics Division (FDD) for the Rossi X-Ray Timing Explorer (RXTE) spacecraft. For this mission, the FDD supports onboard attitude determination and ephemeris propagation by supplying ground-based orbit and attitude solutions and calibration results. The first phase of that support was to provide launch window analyses. As the launch window was determined, acquisition attitudes were calculated and calibration slews were planned. postlaunch, these slews provided the basis for ground determined calibration. Ground determined calibration results are used to improve the accuracy of onboard solutions. The FDD is applying new calibration tools designed to facilitate use of the simultaneous, high-accuracy star observations from the two RXTE star trackers for ground attitude determination and calibration. An evaluation of the performance of these tools is presented. The FDD provides updates to the onboard star catalog based on preflight analysis and analysis of flight data. The in-flight results of the mission support in each area are summarized and compared with pre-mission expectations.

  2. Crustal dynamics project session 4 validation and intercomparison experiments 1979-1980 report

    NASA Technical Reports Server (NTRS)

    Liebrecht, P.; Kolenkiewicz, R.; Ryan, J.; Hothem, L.

    1983-01-01

    As part of the Crustal Dynamics Project, an experiment was performed to verify the ability of Satellite Laser Ranging (SLR), Very Long Baseline interferometry (VLBI) and Doppler Satellite Positioning System (Doppler) techniques to estimate the baseline distances between several locations. The Goddard Space Flight Center (GSFC) lasers were in operation at all five sites available to them. The ten baselines involved were analyzed using monthly orbits and various methods of selecting data. The standard deviation of the monthly SLR baseline lengths was at the 7 cm level. The GSFC VLBI (Mark III) data was obtained during three separate experiments. November 1979 at Haystack and Owens Valley, and April and July 1980 at Haystack, Owens Valley, and Fort Davis. Repeatability of the VLBI in determining baseline lengths was calculated to be at the 2 cm level. Jet Propulsion Laboratory (JPL) VLBI (Mark II) data was acquired on the Owens Valley to Goldstone baseline on ten occasions between August 1979 and November 1980. The repeatability of these baseline length determinations was calculated to be at the 5 cm level. National Geodetic Survey (NGS) Doppler data was acquired at all five sites in January 1980. Repeatability of the Doppler determined baseline lengths results were calculated at approximately 30 cm. An intercomparison between baseline distances and associated parameters was made utilizing SLR, VLBI, and Doppler results on all available baselines. The VLBI and SLR length determinations were compared on four baselines with a resultant mean difference of -1 cm and a maximum difference of 12 cm. The SLR and Doppler length determinations were compared on ten baselines with a resultant mean difference of about 30 cm and a maximum difference of about 60 cm. The VLBI and Doppler lengths from seven baselines showed a resultant mean difference of about 30 cm and maximum difference of about 1 meter. The intercomparison of baseline orientation parameters were consistent with past analysis.

  3. 1024-channel portable gamma-ray spectrometer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McGibbon, A.L.

    An instrument is described which is designed to determine radioactive isotope spectra in the field under adverse environmental conditions. The instrument is battery-powered, stores and compares multiple spectra, and performs computations upon the resulting displayed graph. (auth)

  4. 25 CFR 63.17 - How does an employer determine suitability for employment and efficiency of service?

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... INTERIOR TRIBAL GOVERNMENT INDIAN CHILD PROTECTION AND FAMILY VIOLENCE PREVENTION Minimum Standards of... application and compare the information provided; (2) Review the results of written record searches requested...

  5. 25 CFR 63.17 - How does an employer determine suitability for employment and efficiency of service?

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... INTERIOR TRIBAL GOVERNMENT INDIAN CHILD PROTECTION AND FAMILY VIOLENCE PREVENTION Minimum Standards of... application and compare the information provided; (2) Review the results of written record searches requested...

  6. A Model Comparison for Characterizing Protein Motions from Structure

    NASA Astrophysics Data System (ADS)

    David, Charles; Jacobs, Donald

    2011-10-01

    A comparative study is made using three computational models that characterize native state dynamics starting from known protein structures taken from four distinct SCOP classifications. A geometrical simulation is performed, and the results are compared to the elastic network model and molecular dynamics. The essential dynamics is quantified by a direct analysis of a mode subspace constructed from ANM and a principal component analysis on both the FRODA and MD trajectories using root mean square inner product and principal angles. Relative subspace sizes and overlaps are visualized using the projection of displacement vectors on the model modes. Additionally, a mode subspace is constructed from PCA on an exemplar set of X-ray crystal structures in order to determine similarly with respect to the generated ensembles. Quantitative analysis reveals there is significant overlap across the three model subspaces and the model independent subspace. These results indicate that structure is the key determinant for native state dynamics.

  7. A novel neutron energy spectrum unfolding code using particle swarm optimization

    NASA Astrophysics Data System (ADS)

    Shahabinejad, H.; Sohrabpour, M.

    2017-07-01

    A novel neutron Spectrum Deconvolution using Particle Swarm Optimization (SDPSO) code has been developed to unfold the neutron spectrum from a pulse height distribution and a response matrix. The Particle Swarm Optimization (PSO) imitates the bird flocks social behavior to solve complex optimization problems. The results of the SDPSO code have been compared with those of the standard spectra and recently published Two-steps Genetic Algorithm Spectrum Unfolding (TGASU) code. The TGASU code have been previously compared with the other codes such as MAXED, GRAVEL, FERDOR and GAMCD and shown to be more accurate than the previous codes. The results of the SDPSO code have been demonstrated to match well with those of the TGASU code for both under determined and over-determined problems. In addition the SDPSO has been shown to be nearly two times faster than the TGASU code.

  8. Determination of indoor radon concentrations at the elementary schools of Fatih district in Istanbul

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kurt, A., E-mail: aziz.kurt@istanbul.edu.tr; Yalcin, L. Sahin, E-mail: latife.sahin@gmail.com; Oktem, Y., E-mail: sgyks@istanbul.edu.tr

    Radon is an odorless, tasteless, colorless noble radioactive gas which is produced within the radioactive decay chain of Uranium. The Radon forms in rocks, diffuses into soil and then escapes into atmosphere. When human exposure to high concentration of radon gas from inside, risk of developing lung cancer is increased. There are many methods to determine {sup 222}Rn concentration in the air. In this study, radon concentration of confined air spaces were measured by using LR-115 solid state nuclear track detectors. 509 LR-115 nuclear trace detectors were placed to 25 schools in Fatih District and they effective dose values weremore » calculated. The results of measurements showed that the radon concentration varies between 40-395 Bq/m{sup 3}. This results compared with Turkey’s limits (400 Bq/m{sup 3}) are low, conversely higher compared with WHO’s limits (100 Bq/m{sup 3}).« less

  9. Determinants of bone density among athletes engaged in weight-bearing and non-weight-bearing activity

    NASA Technical Reports Server (NTRS)

    Block, Jon E.; Friedlander, Anne L.; Brooks, George A.; Steiger, Peter; Stubbs, Harrison A.

    1989-01-01

    The effect of weight bearing activity on the bone density was investigated in athletes by comparing the measures of bone density of athletes engaged in weight-training programs with those of polo players and nonexercising subjects. All subjects had measurements of spinal trabecular and integral bone density by quantitative tomography, as well as determinations of hip bone density by dual photon absorptiometry. Results confirmed previous findings by Block et al. (1987) of significantly greater bone density among highly trained athletes compared with nonexercising subjects of similar age. Results also indicated that athletes engaged in non-weight-bearing forms of rigorous exercise had greater levels of bone density. However, as the participants in this study were exceptional athletes, engaged in a strenuous sport with both aerobic and heavy resistance components, a confirmation of these data is needed, using larger samples of individuals.

  10. Electromagnetic corrections to the hadronic vacuum polarization of the photon within QEDL and QEDM

    NASA Astrophysics Data System (ADS)

    Bussone, Andrea; Della Morte, Michele; Janowski, Tadeusz

    2018-03-01

    We compute the leading QED corrections to the hadronic vacuum polarization (HVP) of the photon, relevant for the determination of leptonic anomalous magnetic moments, al. We work in the electroquenched approximation and use dynamical QCD configurations generated by the CLS initiative with two degenerate flavors of nonperturbatively O(a)-improved Wilson fermions. We consider QEDL and QEDM to deal with the finite-volume zero modes. We compare results for the Wilson loops with exact analytical determinations. In addition we make sure that the volumes and photon masses used in QEDM are such that the correct dispersion relation is reproduced by the energy levels extracted from the charged pions two-point functions. Finally we compare results for pion masses and the HVP between QEDL and QEDM. For the vacuum polarization, corrections with respect to the pure QCD case, at fixed pion masses, turn out to be at the percent level.

  11. Determining XV-15 aeroelastic modes from flight data with frequency-domain methods

    NASA Technical Reports Server (NTRS)

    Acree, C. W., Jr.; Tischler, Mark B.

    1993-01-01

    The XV-15 tilt-rotor wing has six major aeroelastic modes that are close in frequency. To precisely excite individual modes during flight test, dual flaperon exciters with automatic frequency-sweep controls were installed. The resulting structural data were analyzed in the frequency domain (Fourier transformed). All spectral data were computed using chirp z-transforms. Modal frequencies and damping were determined by fitting curves to frequency-response magnitude and phase data. The results given in this report are for the XV-15 with its original metal rotor blades. Also, frequency and damping values are compared with theoretical predictions made using two different programs, CAMRAD and ASAP. The frequency-domain data-analysis method proved to be very reliable and adequate for tracking aeroelastic modes during flight-envelope expansion. This approach required less flight-test time and yielded mode estimations that were more repeatable, compared with the exponential-decay method previously used.

  12. A method to determine fault vectors in 4H-SiC from stacking sequences observed on high resolution transmission electron microscopy images

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wu, Fangzhen; Wang, Huanhuan; Raghothamachar, Balaji

    A new method has been developed to determine the fault vectors associated with stacking faults in 4H-SiC from their stacking sequences observed on high resolution TEM images. This method, analogous to the Burgers circuit technique for determination of dislocation Burgers vector, involves determination of the vectors required in the projection of the perfect lattice to correct the deviated path constructed in the faulted material. Results for several different stacking faults were compared with fault vectors determined from X-ray topographic contrast analysis and were found to be consistent. This technique is expected to applicable to all structures comprising corner shared tetrahedra.

  13. A software tool for determination of breast cancer treatment methods using data mining approach.

    PubMed

    Cakır, Abdülkadir; Demirel, Burçin

    2011-12-01

    In this work, breast cancer treatment methods are determined using data mining. For this purpose, software is developed to help to oncology doctor for the suggestion of application of the treatment methods about breast cancer patients. 462 breast cancer patient data, obtained from Ankara Oncology Hospital, are used to determine treatment methods for new patients. This dataset is processed with Weka data mining tool. Classification algorithms are applied one by one for this dataset and results are compared to find proper treatment method. Developed software program called as "Treatment Assistant" uses different algorithms (IB1, Multilayer Perception and Decision Table) to find out which one is giving better result for each attribute to predict and by using Java Net beans interface. Treatment methods are determined for the post surgical operation of breast cancer patients using this developed software tool. At modeling step of data mining process, different Weka algorithms are used for output attributes. For hormonotherapy output IB1, for tamoxifen and radiotherapy outputs Multilayer Perceptron and for the chemotherapy output decision table algorithm shows best accuracy performance compare to each other. In conclusion, this work shows that data mining approach can be a useful tool for medical applications particularly at the treatment decision step. Data mining helps to the doctor to decide in a short time.

  14. Turf Conversion Measurement and Verification Protocol

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kurnik, Charles W.; Stoughton, Kate M.; Figueroa, Jorge

    This measurement and verification (M and V) protocol provides procedures for energy service companies (ESCOs) and water efficiency service companies (WESCOs) to determine water savings as a result of water conservation measures (WCMs) in energy performance contracts associated with converting turfgrass or other water-intensive plantings to water-wise and sustainable landscapes. The water savings are determined by comparing the baseline water use to the water use after the WCM has been implemented. This protocol outlines the basic structure of the M and V plan, and details the procedures to use to determine water savings.

  15. Determination of Diffusion Parameters of Mean Moderation by Means of a Pulsed Neutron Source. I. Dowtherm A at 20 C; DETERMINAZIONE DEI PARAMETRI DI DIFFUSIONE DEI MEZZI MODERANTI CONIL METODO DELLA SORGENTE DI NEUTRONI PULSATA. I.DOWTHERM A (TEMPERATURE 20 C)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Demanins, F.; Rado, V.; Vinci, F.

    1963-04-01

    The macroscopic absorption cross section, diffusion constant, diffusion cooling constant, transport mean free patu, extrapolated distance, diffusion length, and mean life for thermal neutrons were determined for Dowtherm A at 20 deg C, using a pulsed neutron source. The experimental assembly and data analysis method are described, and the results are compared with other determinations. (auth)

  16. Comparison of Several Methods for Determining the Internal Resistance of Lithium Ion Cells

    PubMed Central

    Schweiger, Hans-Georg; Obeidi, Ossama; Komesker, Oliver; Raschke, André; Schiemann, Michael; Zehner, Christian; Gehnen, Markus; Keller, Michael; Birke, Peter

    2010-01-01

    The internal resistance is the key parameter for determining power, energy efficiency and lost heat of a lithium ion cell. Precise knowledge of this value is vital for designing battery systems for automotive applications. Internal resistance of a cell was determined by current step methods, AC (alternating current) methods, electrochemical impedance spectroscopy and thermal loss methods. The outcomes of these measurements have been compared with each other. If charge or discharge of the cell is limited, current step methods provide the same results as energy loss methods. PMID:22219678

  17. A Winner Determination Algorithm for Combinatorial Auctions Based on Hybrid Artificial Fish Swarm Algorithm

    NASA Astrophysics Data System (ADS)

    Zheng, Genrang; Lin, ZhengChun

    The problem of winner determination in combinatorial auctions is a hotspot electronic business, and a NP hard problem. A Hybrid Artificial Fish Swarm Algorithm(HAFSA), which is combined with First Suite Heuristic Algorithm (FSHA) and Artificial Fish Swarm Algorithm (AFSA), is proposed to solve the problem after probing it base on the theories of AFSA. Experiment results show that the HAFSA is a rapidly and efficient algorithm for The problem of winner determining. Compared with Ant colony Optimization Algorithm, it has a good performance with broad and prosperous application.

  18. The determination of antipyrine elimination in saliva by liquid chromatography.

    PubMed

    Gartzke, J; Jäger, H

    1991-01-01

    A simple, fast and reliable liquid chromatographic method for the determination of antipyrine in saliva is described. The elimination of antipyrine is a good indicator for general evaluation of the liver function for dispositional purposes for example in occupational and environmental medicine. The described LC method was compared with a more extensive photometric procedure. The results obtained from both methods show very good correlation. Only one measurement is necessary to determine the antipyrine clearance. Furthermore the antipyrine dosage can be minimized, because of the sensitivity of the HPLC-method.

  19. Virtual screening of cocrystal formers for CL-20

    NASA Astrophysics Data System (ADS)

    Zhou, Jun-Hong; Chen, Min-Bo; Chen, Wei-Ming; Shi, Liang-Wei; Zhang, Chao-Yang; Li, Hong-Zhen

    2014-08-01

    According to the structure characteristics of 2,4,6,8,10,12-hexanitrohexaazaisowurtzitane (CL-20) and the kinetic mechanism of the cocrystal formation, the method of virtual screening CL-20 cocrystal formers by the criterion of the strongest intermolecular site pairing energy (ISPE) was proposed. In this method the strongest ISPE was thought to determine the first step of the cocrystal formation. The prediction results for four sets of common drug molecule cocrystals by this method were compared with those by the total ISPE method from the reference (Musumeci et al., 2011), and the experimental results. This method was then applied to virtually screen the CL-20 cocrystal formers, and the prediction results were compared with the experimental results.

  20. Determination of intra-axial brain tumors cellularity through the analysis of T2 Relaxation time of brain tumors before surgery using MATLAB software.

    PubMed

    Abdolmohammadi, Jamil; Shafiee, Mohsen; Faeghi, Fariborz; Arefan, Douman; Zali, Alireza; Motiei-Langroudi, Rouzbeh; Farshidfar, Zahra; Nazarlou, Ali Kiani; Tavakkoli, Ali; Yarham, Mohammad

    2016-08-01

    Timely diagnosis of brain tumors could considerably affect the process of patient treatment. To do so, para-clinical methods, particularly MRI, cannot be ignored. MRI has so far answered significant questions regarding tumor characteristics, as well as helping neurosurgeons. In order to detect the tumor cellularity, neuro-surgeons currently have to sample specimens by biopsy and then send them to the pathology unit. The aim of this study is to determine the tumor cellularity in the brain. In this cross-sectional study, 32 patients (18 males and 14 females from 18-77 y/o) were admitted to the neurosurgery department of Shohada-E Tajrish Hospital in Tehran, Iran from April 2012 to February 2014. In addition to routine pulse sequences, T2W Multi echo pulse sequences were taken and the images were analyzed using the MATLAB software to determine the brain tumor cellularity, compared with the biopsy. These findings illustrate the need for more T2 relaxation time decreases, the higher classes of tumors will stand out in the designed table. In this study, the results show T2 relaxation time with a 85% diagnostic weight, compared with the biopsy, to determine the brain tumor cellularity (p<0.05). Our results indicate that the T2 relaxation time feature is the best method to distinguish and present the degree of intra-axial brain tumors cellularity (85% accuracy compared to biopsy). The use of more data is recommended in order to increase the percent accuracy of this techniques.

  1. Comparison of Body Composition Measurements Using a New Caliper, Two Established Calipers, Hydrostatic Weighing, and BodPod

    PubMed Central

    TALBERT, ERIN E.; FLYNN, MICHAEL G.; BELL, JEFFREY W.; CARRILLO, ANDRES E.; DILL, MARQUITA D.; CHRISTENSEN, CHRISTIANIA N.; THOMPSON, COLLEEN M.

    2009-01-01

    Purposes (1) To compare the Lafayette Instruments (LI) skinfold caliper to the Lange (L) and Harpenden (H) calipers using a diverse subject population. (2) To determine the validity of the LI caliper in a subset of subjects by comparing body compositions from skinfold thicknesses to those measured by hydrostatic weighing (HW) and air displacement plethysmography (ADP). (3) To compare measurements obtained by experienced (EX) and inexperienced (IX) technicians using all three calipers. Methods Skinfold measurements were performed by both EX and IX technicians using three different calipers on 21 younger (21.2 ± 1.5 yrs) and 20 older (59.2 ± 4 yrs) subjects. Body compositions were calculated using the Jackson-Pollock seven-site and three-site formulas. HW and ADP tests were performed on a subset of subjects (10 younger, 10 older). Results No significant differences existed between LI and L or H when measurements were made by EX. Further, the LI-EX measurements were highly correlated to both H-EX and L-EX. No significant differences existed in the subgroup between LI-EX and HW or ADP. Skinfold determinations made by EX and IX were similar. Conclusions Similar body compositions determined using LI, H, and L suggest that LI determines body composition as effectively as H and L. High correlations between the three calipers support this notion. Similar results between LI and HW/ADP subgroup suggest that the LI caliper may be a valid method of measuring body composition. Overall, performance by IX was similar to EX and suggests similar ease of use for all three calipers. PMID:28572871

  2. Optimizing Tsunami Forecast Model Accuracy

    NASA Astrophysics Data System (ADS)

    Whitmore, P.; Nyland, D. L.; Huang, P. Y.

    2015-12-01

    Recent tsunamis provide a means to determine the accuracy that can be expected of real-time tsunami forecast models. Forecast accuracy using two different tsunami forecast models are compared for seven events since 2006 based on both real-time application and optimized, after-the-fact "forecasts". Lessons learned by comparing the forecast accuracy determined during an event to modified applications of the models after-the-fact provide improved methods for real-time forecasting for future events. Variables such as source definition, data assimilation, and model scaling factors are examined to optimize forecast accuracy. Forecast accuracy is also compared for direct forward modeling based on earthquake source parameters versus accuracy obtained by assimilating sea level data into the forecast model. Results show that including assimilated sea level data into the models increases accuracy by approximately 15% for the events examined.

  3. Comparison of analytical methods for the determination of histamine in reference canned fish samples

    NASA Astrophysics Data System (ADS)

    Jakšić, S.; Baloš, M. Ž.; Mihaljev, Ž.; Prodanov Radulović, J.; Nešić, K.

    2017-09-01

    Two screening methods for histamine in canned fish, an enzymatic test and a competitive direct enzyme-linked immunosorbent assay (CD-ELISA), were compared with the reversed-phase liquid chromatography (RP-HPLC) standard method. For enzymatic and CD-ELISA methods, determination was conducted according to producers’ manuals. For RP-HPLC, histamine was derivatized with dansyl-chloride, followed by RP-HPLC and diode array detection. Results of analysis of canned fish, supplied as reference samples for proficiency testing, showed good agreement when histamine was present at higher concentrations (above 100 mg kg-1). At a lower level (16.95 mg kg-1), the enzymatic test produced some higher results. Generally, analysis of four reference samples according to CD-ELISA and RP-HPLC showed good agreement for histamine determination (r=0.977 in concentration range 16.95-216 mg kg-1) The results show that the applied enzymatic test and CD-ELISA appeared to be suitable screening methods for the determination of histamine in canned fish.

  4. Synchrotron radiation determination of elemental concentrations in coal

    USGS Publications Warehouse

    Chen, J.R.; Martys, N.; Chao, E.C.T.; Minkin, J.A.; Thompson, C.L.; Hanson, A.L.; Kraner, H.W.; Jones, K.W.; Gordon, B.M.; Mills, R.E.

    1984-01-01

    The variations with depth of the elemental concentrations in vitrinites in a series of vitrites have been determined using radiation from the Cornell high energy synchrotron source. All of the vitrites were selected from a single drill core sample of coal from the Emery coalfield, Utah. The results are compared with similar determinations using the Heidelberg proton microprobe. The advantages and disadvantages of the two techniques are discussed. Results are reported for S, Ca, Ti, Fe, Zn, Br, and Sr. For example, it is found that Fe increases from top to bottom of the coal bed in contrast to S, which decreases from top to bottom of the bed. Other features of the two data sets are also described. ?? 1984.

  5. Optimal projection method determination by Logdet Divergence and perturbed von-Neumann Divergence.

    PubMed

    Jiang, Hao; Ching, Wai-Ki; Qiu, Yushan; Cheng, Xiao-Qing

    2017-12-14

    Positive semi-definiteness is a critical property in kernel methods for Support Vector Machine (SVM) by which efficient solutions can be guaranteed through convex quadratic programming. However, a lot of similarity functions in applications do not produce positive semi-definite kernels. We propose projection method by constructing projection matrix on indefinite kernels. As a generalization of the spectrum method (denoising method and flipping method), the projection method shows better or comparable performance comparing to the corresponding indefinite kernel methods on a number of real world data sets. Under the Bregman matrix divergence theory, we can find suggested optimal λ in projection method using unconstrained optimization in kernel learning. In this paper we focus on optimal λ determination, in the pursuit of precise optimal λ determination method in unconstrained optimization framework. We developed a perturbed von-Neumann divergence to measure kernel relationships. We compared optimal λ determination with Logdet Divergence and perturbed von-Neumann Divergence, aiming at finding better λ in projection method. Results on a number of real world data sets show that projection method with optimal λ by Logdet divergence demonstrate near optimal performance. And the perturbed von-Neumann Divergence can help determine a relatively better optimal projection method. Projection method ia easy to use for dealing with indefinite kernels. And the parameter embedded in the method can be determined through unconstrained optimization under Bregman matrix divergence theory. This may provide a new way in kernel SVMs for varied objectives.

  6. Determining Chronic Disease Prevalence in Local Populations Using Emergency Department Surveillance

    PubMed Central

    Long, Judith A.; Wall, Stephen P.; Carr, Brendan G.; Satchell, Samantha N.; Braithwaite, R. Scott; Elbel, Brian

    2015-01-01

    Objectives. We sought to improve public health surveillance by using a geographic analysis of emergency department (ED) visits to determine local chronic disease prevalence. Methods. Using an all-payer administrative database, we determined the proportion of unique ED patients with diabetes, hypertension, or asthma. We compared these rates to those determined by the New York City Community Health Survey. For diabetes prevalence, we also analyzed the fidelity of longitudinal estimates using logistic regression and determined disease burden within census tracts using geocoded addresses. Results. We identified 4.4 million unique New York City adults visiting an ED between 2009 and 2012. When we compared our emergency sample to survey data, rates of neighborhood diabetes, hypertension, and asthma prevalence were similar (correlation coefficient = 0.86, 0.88, and 0.77, respectively). In addition, our method demonstrated less year-to-year scatter and identified significant variation of disease burden within neighborhoods among census tracts. Conclusions. Our method for determining chronic disease prevalence correlates with a validated health survey and may have higher reliability over time and greater granularity at a local level. Our findings can improve public health surveillance by identifying local variation of disease prevalence. PMID:26180983

  7. Determination of the actual evapotranspiration by using remote sensing methods

    NASA Astrophysics Data System (ADS)

    Bora, Eser

    2017-10-01

    Evapotranspiration is so crucial for determining amount of the irrigation and the effective water management planning. Moreover, it is vital for determining agricultural drought management and determination the actual evapotranspiration ın a region is critical for early drought warning systems. The main object of this study was to assess accuracy of the remote sensing method (METRIC) by calibrating with the bowen ratio observations at the same time. The research was carried out in the west of Marmara Region, Turkey. Landsat 5 images was used to determine the metric algorithm. By using this algorithms are found. Landsat 5 images file were used to determine actual evapotranspiration and the image's date was June 11 in 2010. This date was used for calibration with available terrestrial observation by using bowen ratio in that time. Landsat images obtained from the web site, earthexplorer.usgs.gov, and results of bowen ratio taken from micrometeorology station. As a result, energy balance parameters that are net radiation, soil heat flux and latent heat flux were compared both metric algorithm and the bowen ration in the images time. The results are found so close to each other.

  8. Spectra resolution for simultaneous spectrophotometric determination of lamivudine and zidovudine components in pharmaceutical formulation of human immunodeficiency virus drug based on using continuous wavelet transform and derivative transform techniques.

    PubMed

    Sohrabi, Mahmoud Reza; Tayefeh Zarkesh, Mahshid

    2014-05-01

    In the present paper, two spectrophotometric methods based on signal processing are proposed for the simultaneous determination of two components of an anti-HIV drug called lamivudine (LMV) and zidovudine (ZDV). The proposed methods are applied to synthetic binary mixtures and commercial pharmaceutical tablets without the need for any chemical separation procedures. The developed methods are based on the application of Continuous Wavelet Transform (CWT) and Derivative Spectrophotometry (DS) combined with the zero cross point technique. The Daubechies (db5) wavelet family (242 nm) and Dmey wavelet family (236 nm) were found to give the best results under optimum conditions for simultaneous analysis of lamivudine and zidovudine, respectively. In addition, the first derivative absorption spectra were selected for the determination of lamivudine and zidovudine at 266 nm and 248 nm, respectively. Assaying various synthetic mixtures of the components validated the presented methods. Mean recovery values were found to be between 100.31% and 100.2% for CWT and 99.42% and 97.37% for DS, respectively for determination of LMV and ZDV. The results obtained from analyzing the real samples by the proposed methods were compared to the HPLC reference method. One-way ANOVA test at 95% confidence level was applied to the results. The statistical data from comparing the proposed methods with the reference method showed no significant differences. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. User-customized brain computer interfaces using Bayesian optimization

    NASA Astrophysics Data System (ADS)

    Bashashati, Hossein; Ward, Rabab K.; Bashashati, Ali

    2016-04-01

    Objective. The brain characteristics of different people are not the same. Brain computer interfaces (BCIs) should thus be customized for each individual person. In motor-imagery based synchronous BCIs, a number of parameters (referred to as hyper-parameters) including the EEG frequency bands, the channels and the time intervals from which the features are extracted should be pre-determined based on each subject’s brain characteristics. Approach. To determine the hyper-parameter values, previous work has relied on manual or semi-automatic methods that are not applicable to high-dimensional search spaces. In this paper, we propose a fully automatic, scalable and computationally inexpensive algorithm that uses Bayesian optimization to tune these hyper-parameters. We then build different classifiers trained on the sets of hyper-parameter values proposed by the Bayesian optimization. A final classifier aggregates the results of the different classifiers. Main Results. We have applied our method to 21 subjects from three BCI competition datasets. We have conducted rigorous statistical tests, and have shown the positive impact of hyper-parameter optimization in improving the accuracy of BCIs. Furthermore, We have compared our results to those reported in the literature. Significance. Unlike the best reported results in the literature, which are based on more sophisticated feature extraction and classification methods, and rely on prestudies to determine the hyper-parameter values, our method has the advantage of being fully automated, uses less sophisticated feature extraction and classification methods, and yields similar or superior results compared to the best performing designs in the literature.

  10. Proteomic Analyses of Corneal Tissue Subjected to Alkali Exposure

    PubMed Central

    Parikh, Toral; Eisner, Natalie; Venugopalan, Praseeda; Yang, Qin; Lam, Byron L.

    2011-01-01

    Purpose. To determine whether exposure to alkaline chemicals results in predictable changes in corneal protein profile. To determine whether protein profile changes are indicative of severity and duration of alkali exposure. Methods. Enucleated bovine and porcine (n = 59 each) eyes were used for exposure to sodium, ammonium, and calcium hydroxide, respectively. Eyes were subjected to fluorescein staining, 5-bromo-2′-deoxy-uridine (BrdU) labeling. Excised cornea was subjected to protein extraction, spectrophotometric determination of protein amount, dynamic light scattering and SDS-PAGE profiling, mass spectrometric protein identification, and iTRAQ-labeled quantification. Select identified proteins were subjected to Western blot and immunohistochemical analyses. Results. Alkali exposure resulted in lower protein extractability from corneal tissue. Elevated aggregate formation was found with strong alkali exposure (sodium hydroxide>ammonium, calcium hydroxide), even with a short duration of exposure compared with controls. The protein yield after exposure varied as a function of postexposure time. Protein profiles changed because of alkali exposure. Concentration and strength of the alkali affected the profile change significantly. Mass spectrometry identified 15 proteins from different bands with relative quantification. Plexin D1 was identified for the first time in the cornea at a protein level that was further confirmed by Western blot and immunohistochemical analyses. Conclusions. Exposure to alkaline chemicals results in predictable and reproducible changes in corneal protein profile. Stronger alkali, longer durations, or both, of exposure resulted in lower yields and significant protein profile changes compared with controls. PMID:20861482

  11. Measurement and interpretation of skin prick test results.

    PubMed

    van der Valk, J P M; Gerth van Wijk, R; Hoorn, E; Groenendijk, L; Groenendijk, I M; de Jong, N W

    2015-01-01

    There are several methods to read skin prick test results in type-I allergy testing. A commonly used method is to characterize the wheal size by its 'average diameter'. A more accurate method is to scan the area of the wheal to calculate the actual size. In both methods, skin prick test (SPT) results can be corrected for histamine-sensitivity of the skin by dividing the results of the allergic reaction by the histamine control. The objectives of this study are to compare different techniques of quantifying SPT results, to determine a cut-off value for a positive SPT for histamine equivalent prick -index (HEP) area, and to study the accuracy of predicting cashew nut reactions in double-blind placebo-controlled food challenge (DBPCFC) tests with the different SPT methods. Data of 172 children with cashew nut sensitisation were used for the analysis. All patients underwent a DBPCFC with cashew nut. Per patient, the average diameter and scanned area of the wheal size were recorded. In addition, the same data for the histamine-induced wheal were collected for each patient. The accuracy in predicting the outcome of the DBPCFC using four different SPT readings (i.e. average diameter, area, HEP-index diameter, HEP-index area) were compared in a Receiver-Operating Characteristic (ROC) plot. Characterizing the wheal size by the average diameter method is inaccurate compared to scanning method. A wheal average diameter of 3 mm is generally considered as a positive SPT cut-off value and an equivalent HEP-index area cut-off value of 0.4 was calculated. The four SPT methods yielded a comparable area under the curve (AUC) of 0.84, 0.85, 0.83 and 0.83, respectively. The four methods showed comparable accuracy in predicting cashew nut reactions in a DBPCFC. The 'scanned area method' is theoretically more accurate in determining the wheal area than the 'average diameter method' and is recommended in academic research. A HEP-index area of 0.4 is determined as cut-off value for a positive SPT. However, in clinical practice, the 'average diameter method' is also useful, because this method provides similar accuracy in predicting cashew nut allergic reactions in the DBPCFC. Trial number NTR3572.

  12. Transmission electron diffraction determination of the Ge(001)-(2 × 1) surface structure

    NASA Astrophysics Data System (ADS)

    Collazo-Davila, C.; Grozea, D.; Landree, E.; Marks, L. D.

    1997-04-01

    The lateral displacements in the Ge(001)-(2 × 1) surface reconstruction have been determined using transmission electron diffraction (TED). The best-fit model includes displacements extending six layers into the bulk. The atomic positions found agree with X-ray studies to within a few hundredths of an ångström. With the positions determined so precisely, it is suggested that the Ge(001)-(2 × 1) surface can now serve as a standard for comparison with theoretical surface structure calculations. The results from the currently available theoretical studies on the surface are compared with the experimentally determined structure.

  13. Effect of Fuel-Air Ratio, Inlet Temperature, and Exhaust Pressure on Detonation

    NASA Technical Reports Server (NTRS)

    Taylor, E S; Leary, W A; Diver, J R

    1940-01-01

    An accurate determination of the end-gas condition was attempted by applying a refined method of analysis to experimental results. The results are compared with those obtained in Technical Report no. 655. The experimental technique employed afforded excellent control over the engine variables and unusual cyclic reproducibility. This, in conjunction with the new analysis, made possible the determination of the state of the end-gas at any instant to a fair degree of precision. Results showed that for any given maximum pressure the maximum permissible end-gas temperature increased as the fuel-air ratio was increased. The tendency to detonate was slightly reduced by an increase in residual gas content resulting from an increase in exhaust backpressure with inlet pressure constant.

  14. An iterative method for near-field Fresnel region polychromatic phase contrast imaging

    NASA Astrophysics Data System (ADS)

    Carroll, Aidan J.; van Riessen, Grant A.; Balaur, Eugeniu; Dolbnya, Igor P.; Tran, Giang N.; Peele, Andrew G.

    2017-07-01

    We present an iterative method for polychromatic phase contrast imaging that is suitable for broadband illumination and which allows for the quantitative determination of the thickness of an object given the refractive index of the sample material. Experimental and simulation results suggest the iterative method provides comparable image quality and quantitative object thickness determination when compared to the analytical polychromatic transport of intensity and contrast transfer function methods. The ability of the iterative method to work over a wider range of experimental conditions means the iterative method is a suitable candidate for use with polychromatic illumination and may deliver more utility for laboratory-based x-ray sources, which typically have a broad spectrum.

  15. DEVELOPMENT AND VALIDATION OF BROMATOMETRIC, DIAZOTIZATION AND VIS-SPECTROPHOTOMETRIC METHODS FOR THE DETERMINATION OF MESALAZINE IN PHARMACEUTICAL FORMULATION.

    PubMed

    Zawada, Elzabieta; Pirianowicz-Chaber, Elzabieta; Somogi, Aleksander; Pawinski, Tomasz

    2017-03-01

    Three new methods were developed for the quantitative determination of mesalazine in the form of the pure substance or in the form of suppositories and tablets - accordingly: bromatometric, diazotization and visible light spectrophotometry method. Optimizing the time and the temperature of the bromination reaction (50⁰C, 50 min) 4-amino-2,3,5,6-tetrabromophenol was obtained. The results obtained were reproducible, accurate and precise. Developed methods were compared to the pharmacopoeial approach - alkalimetry in an aqueous medium. The validation parameters of all methods were comparable. Developed methods for quantification of mesalazine are a viable alternative to other more expensive approaches.

  16. Determination of the mechanical properties of SnSe, a novel layered semiconductor

    NASA Astrophysics Data System (ADS)

    Lamuta, Caterina; Campi, Davide; Pagnotta, Leonardo; Dasadia, Abhay; Cupolillo, Anna; Politano, Antonio

    2018-05-01

    Tin selenide (SnSe) is one the most promising materials for flexible electronics. However, experiments on the direct determination of its mechanical properties are still missing. By means of depth-sensing nanoindentation experiments, we directly evaluate the Young's modulus of bulk single crystals of tin selenide (25.3 GPa), as well as their hardness (0.82 GPa). Experimental results are compared with predictions by density functional theory, performed using eleven different functionals. The discrepancies between the experimental results and the thoretical predictions can be ascribed to the oxidation of the SnSe surface, detected by X-ray photoelectron spectroscopy.

  17. Monosodium glutamate for simple photometric iron analysis

    NASA Astrophysics Data System (ADS)

    Prasetyo, E.

    2018-01-01

    Simple photometric method for iron analysis using monosodium glutamate (MSG) was proposed. The method could be used as an alternative method, which was technically simple, economic, quantitative, readily available, scientifically sound and environmental friendly. Rapid reaction of iron (III) with glutamate in sodium chloride-hydrochloric acid buffer (pH 2) to form red-brown complex was served as a basis in the photometric determination, which obeyed the range of iron (III) concentration 1.6 - 80 µg/ml. This method could be applied to determine iron concentration in soil with satisfactory results (accuracy and precision) compared to other photometric and atomic absorption spectrometry results.

  18. The pharmacokinetics of a single oral or rectal dose of concurrently administered isoniazid, rifampin, pyrazinamide, and ethambutol in Asian elephants (Elephas maximus).

    PubMed

    P Brock, A; Isaza, R; Egelund, E F; Hunter, R P; Peloquin, C A

    2014-10-01

    Tuberculosis, caused by Mycobacterium tuberculosis, is a disease of concern in captive Asian elephants (Elephas maximus). Treatment for tuberculosis in elephants utilizes multidrug protocols combining isoniazid, rifampin, pyrazinamide, and/or ethambutol. In this study, a single, coformulated dose of isoniazid 5 mg/kg, rifampin 10 mg/kg, pyrazinamide 30 mg/kg, and ethambutol 30 mg/kg was administered orally to six Asian elephants, and rectally to five elephants using a cross-over design. Blood samples were collected serially over 24 h. Pyrazinamide and ethambutol concentrations were determined using validated gas chromatography assays. Isoniazid and rifampin concentrations were determined using validated high-performance liquid chromatography assays. Rectal isoniazid produced an earlier Tmax compared with oral administration. Oral isoniazid resulted in a comparatively lower Cmax , but higher AUC values compared with rectal isoniazid. Oral rifampin and oral ethambutol were well absorbed while rectal rifampin was not. Oral pyrazinamide produced comparatively higher Cmax and AUC values compared with rectal pyrazinamide. Results of this study indicate that currently recommended therapeutic monitoring sample collection times for rectal isoniazid and oral rifampin do not provide an accurate assessment of exposure for these drugs. This study demonstrates notable individual variability, indicating that dosing of these medications requires individual monitoring and provides additional information to guide the clinician when treating elephants. © 2014 John Wiley & Sons Ltd.

  19. Thermo-economic comparative analysis of gas turbine GT10 integrated with air and steam bottoming cycle

    NASA Astrophysics Data System (ADS)

    Czaja, Daniel; Chmielnak, Tadeusz; Lepszy, Sebastian

    2014-12-01

    A thermodynamic and economic analysis of a GT10 gas turbine integrated with the air bottoming cycle is presented. The results are compared to commercially available combined cycle power plants based on the same gas turbine. The systems under analysis have a better chance of competing with steam bottoming cycle configurations in a small range of the power output capacity. The aim of the calculations is to determine the final cost of electricity generated by the gas turbine air bottoming cycle based on a 25 MW GT10 gas turbine with the exhaust gas mass flow rate of about 80 kg/s. The article shows the results of thermodynamic optimization of the selection of the technological structure of gas turbine air bottoming cycle and of a comparative economic analysis. Quantities are determined that have a decisive impact on the considered units profitability and competitiveness compared to the popular technology based on the steam bottoming cycle. The ultimate quantity that can be compared in the calculations is the cost of 1 MWh of electricity. It should be noted that the systems analyzed herein are power plants where electricity is the only generated product. The performed calculations do not take account of any other (potential) revenues from the sale of energy origin certificates. Keywords: Gas turbine air bottoming cycle, Air bottoming cycle, Gas turbine, GT10

  20. Electronic structure of shandite Co3Sn2S2

    NASA Astrophysics Data System (ADS)

    Dedkov, Y. S.; Holder, M.; Molodtsov, S. L.; Rosner, H.

    2008-03-01

    The electronic structure of shandite Co3Sn2S2 was determined by photoelectron spectroscopy and compared with ab initio band structure calculations. Presented results give evidence that this compound has half-metallic ferromagnetic properties.

  1. The evaporation of a drop of mercury

    NASA Astrophysics Data System (ADS)

    Winter, Thomas G.

    2003-08-01

    The evaporative rates of two drops of mercury at room temperature are determined experimentally and theoretically. The resulting mercury vapor levels are estimated and measured, compared with the OSHA permissible exposure limit, and found to be small by comparison.

  2. Circumferential finger measurements utilizing a torque meter to increase reliability.

    PubMed

    King, T I

    1993-01-01

    The purpose of this study was to compare the reliabilities of two methods of measuring finger circumference. Traditionally, finger circumference is determined clinically by the use of a tape measure. In this study, a tape-measure device for recording finger circumference utilizing a torque meter was compared with the traditional method to determine reliability differences. Ninety-two occupational therapists and occupational therapy students obtained circumferential measurements of the author's left index finger at the middle of the proximal phalanx utilizing the two methods. The readings obtained for each method were analyzed to determine the coefficient of variation and to compare their variances. The coefficient of variation for the traditional method was 2.92 and for the device utilizing the torque meter was 0.75. The F ratio was 15.63, which is significant at the 0.01 level. The results of this study indicate greater interrater reliability using a device that can accurately measure torque and allow the therapist to control the amount of tension applied when obtaining circumferential measurements using a tape measure.

  3. A heterodyne refractometer for air index of refraction and air density measurements

    NASA Astrophysics Data System (ADS)

    Fang, H.; Picard, A.; Juncar, P.

    2002-04-01

    We briefly describe a heterodyne refractometer developed at the BIPM in collaboration with the BNM/INM conservatory. The heart of the refractometer, a double Fabry-Perot interferometer, is placed inside the balance case of a very sensitive 1 kg mass comparator, the FB2 balance. Comparisons between methods using refractometry and the NPL revised Edlén formulas, carried out for a period of nine months, yielded a difference in air index of refraction of 4×10-8 with a standard deviation of 1×10-8. The variation of air index of refraction was about 1.5×10-5 during the study. Precise determinations of the short-term and long-term stability of the Fabry-Perot cavity, made of Zerodur, were also achieved. For monitoring air density, results obtained with the refractometry method were compared with those deduced from two other methods: the CIPM formula for the density of moist air and the use of buoyancy artifacts. The response characteristics for the three determinations were comparable and the agreement among the air density determinations was within 1×10-5 kg m-3.

  4. Resistance of three implant-abutment interfaces to fatigue testing

    PubMed Central

    RIBEIRO, Cleide Gisele; MAIA, Maria Luiza Cabral; SCHERRER, Susanne S.; CARDOSO, Antonio Carlos; WISKOTT, H. W. Anselm

    2011-01-01

    The design and retentive properties of implant-abutment connectors affect the mechanical resistance of implants. A number of studies have been carried out to compare the efficacy of connecting mechanisms between abutment and fixture. Objectives The aims of this study were: 1) to compare 3 implant-abutment interfaces (external hexagon, internal hexagon and cone-in-cone) regarding the fatigue resistance of the prosthetic screw, 2) to evaluate the corresponding mode of failure, and 3) to compare the results of this study with data obtained in previous studies on Nobel Biocare and Straumann connectors. Materials and Methods In order to duplicate the alternating and multivectorial intraoral loading pattern, the specimens were submitted to the rotating cantilever beam test. The implants, abutments and restoration analogs were spun around their longitudinal axes while a perpendicular force was applied to the external end. The objective was to determine the force level at which 50% of the specimens survived 106 load cycles. The mean force levels at which 50% failed and the corresponding 95% confidence intervals were determined using the staircase procedure. Results The external hexagon interface presented better than the cone-in-cone and internal hexagon interfaces. There was no significant difference between the cone-in-cone and internal hex interfaces. Conclusion Although internal connections present a more favorable design, this study did not show any advantage in terms of strength. The external hexagon connector used in this study yielded similar results to those obtained in a previous study with Nobel Biocare and Straumann systems. However, the internal connections (cone-in-cone and internal hexagon) were mechanically inferior compared to previous results. PMID:21710094

  5. Evaluation of Factors Determining the Results of Vocational Rehabilitation. Norwegian Monographs on Medical Science.

    ERIC Educational Resources Information Center

    Gogstad, Anders C.

    Physical disability from disease or injury often results in a permanent state of social insufficiency, especially when the disability is reinforced by individual or environmental factors. In a study of almost 700 persons treated at a Norwegian rehabilitation center, regression analysis was used to compare those who benefited from the program with…

  6. The Masters of Economics: Where Are We Now?

    ERIC Educational Resources Information Center

    McCoy, James P.; Milkman, Martin I.; Marjadi, Riza

    2014-01-01

    In this article, the authors present results from a survey of Masters of Economics program directors to determine the missions, inputs, and outcomes of these degree programs throughout the United States and Canada. They compare results of this survey to those of two previous studies that they conducted 20 and 10 years ago. Respondents were asked…

  7. Comparative Evaluation of Sealing Ability of Three Newer Root Canal Obturating Materials Guttaflow, Resilon and Thermafil: An In Vitro Study

    PubMed Central

    H Bhandi, Shilpa; T S, Subhash

    2013-01-01

    Introduction: Microleakage continues to be a main reason for failure of root canal treatment where the challenge has been to achieve an adequate seal between the internal structure and the main obturating material. The objective of this study is to compare the sealing ability of 3 newer obturating materials GuttaFlow, Resilon/Epiphany system (RES) and Thermafil, using silver nitrate dye and observing under stereomicroscope. Methodology: Thirty single rooted teeth were divided into following groups. Group I : GuttaFlow ;Group II : Resilon /Epiphany sealer Group III : Thermafil with AH-Plus sealer. Teeth were decoronated and instrumented with profile rotary system and obturated with specified materials. Apical seal was determined by dye penetration method using silver nitrate. Then the specimens were transversely sectioned at each mm till 3 mm from the apex. Dye leakage was determined using stereomicroscope. Statistical analysis of the results was performed using Kruskall-Wallis test. Results: The results showed that Group II i.e., Resilon with Epiphany sealer showed the least amount of microleakage when compared to Group I i.e., GuttaFlow and Group III i.e., Thermafil with AH-plus sealer. Conclusion: Based on the results of this study it can be concluded that RES had higher sealing ability followed by Thermafil and GuttaFlow in vitro but further studies have to be carried out to make a direct correlation between these results and invivo situation. How to cite this article: Bhandi S H, Subhash T S. Comparative Evaluation of Sealing Ability of Three Newer Root Canal Obturating Materials Guttaflow, Resilon and Thermafil: An In Vitro Study. J Int Oral Health 2013; 5(1):54-65. PMID:24155579

  8. Heating of solid targets with laser pulses

    NASA Technical Reports Server (NTRS)

    Bechtel, J. H.

    1975-01-01

    Analytical and numerical solutions to the heat-conduction equation are obtained for the heating of absorbing media with pulsed lasers. The spatial and temporal form of the temperature is determined using several different models of the laser irradiance. Both surface and volume generation of heat are discussed. It is found that if the depth of thermal diffusion for the laser-pulse duration is large compared to the optical-attenuation depth, the surface- and volume-generation models give nearly identical results. However, if the thermal-diffusion depth for the laser-pulse duration is comparable to or less than the optical-attenuation depth, the surface-generation model can give significantly different results compared to the volume-generation model. Specific numerical results are given for a tungsten target irradiated by pulses of different temporal durations and the implications of the results are discussed with respect to the heating of metals by picosecond laser pulses.

  9. Comparison of Nested PCR and RFLP for Identification and Classification of Malassezia Yeasts from Healthy Human Skin

    PubMed Central

    Oh, Byung Ho; Song, Young Chan; Choe, Yong Beom; Ahn, Kyu Joong

    2009-01-01

    Background Malassezia yeasts are normal flora of the skin found in 75~98% of healthy subjects. The accurate identification of the Malassezia species is important for determining the pathogenesis of the Malassezia yeasts with regard to various skin diseases such as Malassezia folliculitis, seborrheic dermatitis, and atopic dermatitis. Objective This research was conducted to determine a more accurate and rapid molecular test for the identification and classification of Malassezia yeasts. Methods We compared the accuracy and efficacy of restriction fragment length polymorphism (RFLP) and the nested polymerase chain reaction (PCR) for the identification of Malassezia yeasts. Results Although both methods demonstrated rapid and reliable results with regard to identification, the nested PCR method was faster. However, 7 different Malassezia species (1.2%) were identified by the nested PCR compared to the RFLP method. Conclusion Our results show that RFLP method was relatively more accurate and reliable for the detection of various Malassezia species compared to the nested PCR. But, in the aspect of simplicity and time saving, the latter method has its own advantages. In addition, the 26S rDNA, which was targeted in this study, contains highly conserved base sequences and enough sequence variation for inter-species identification of Malassezia yeasts. PMID:20523823

  10. Cytotoxicity of seven bisphenol analogues compared to bisphenol A and relationships with membrane affinity data.

    PubMed

    Russo, Giacomo; Capuozzo, Antonella; Barbato, Francesco; Irace, Carlo; Santamaria, Rita; Grumetto, Lucia

    2018-06-01

    Bisphenol A (BPA) is a chemical used in numerous industrial applications. Due to its well ascertained toxicity as endocrine disruptor, industries have started to replace it with other bisphenols whose alleged greater safety is scarcely supported by literature studies. In this study, the toxicity of seven BPA analogues was evaluated using both in silico and in vitro techniques, as compared to BPA toxicity. Furthermore, their affinity indexes for phospholipids (i.e. phospholipophilicity) were determined by immobilized artificial membrane liquid chromatography (IAM-LC) and possible relationships with in vitro toxic activity were also investigated. The results on four different cell cultures yielded similar ranking of toxicity for the bisphenols considered, with IC 50 values confirming their poor acute toxicity. As compared to BPA, bisphenol AF, bisphenol B, bisphenol M, and bisphenol A diglycidyl ether resulted more toxic, while bisphenol S, bisphenol F and bisphenol E were found as the less toxic congeners. These results are partly consistent with the scale of phospholipid affinity showing that toxicity increases at increasing membrane affinity. Therefore, phospholipophilicity determination can be assumed as a useful preliminary tool to select less toxic congeners to surrogate BPA in industrial applications. Copyright © 2018 Elsevier Ltd. All rights reserved.

  11. Immune and hormonal activity in adults suffering from depression.

    PubMed

    Nunes, S O V; Reiche, E M V; Morimoto, H K; Matsuo, T; Itano, E N; Xavier, E C D; Yamashita, C M; Vieira, V R; Menoli, A V; Silva, S S; Costa, F B; Reiche, F V; Silva, F L V; Kaminami, M S

    2002-05-01

    An association between depression and altered immune and hormonal systems has been suggested by the results of many studies. In the present study we carried out immune and hormonal measurements in 40 non-medicated, ambulatory adult patients with depression determined by CID-10 criteria and compared with 34 healthy nondepressed subjects. The severity of the condition was determined with the Hamilton Depression Rating Scale. Of 40 depressed patients, 31 had very severe and 9 severe or moderate depression, 29 (72.5%) were females and 11 (27.5%) were males (2.6:1 ratio). The results revealed a significant reduction of albumin and elevation of alpha-1, alpha-2 and beta-globulins, and soluble IL-2 receptor in patients with depression compared to the values obtained for nondepressed subjects (P<0.05). The decrease lymphocyte proliferation in response to a mitogen was significantly lower in severely or moderately depressed patients when compared to control (P<0.05). These data confirm the immunological disturbance of acute phase proteins and cellular immune response in patients with depression. Other results may be explained by a variety of interacting factors such as number of patients, age, sex, and the nature, severity and/or duration of depression. Thus, the data obtained should be interpreted with caution and the precise clinical relevance of these findings requires further investigation.

  12. First European interlaboratory comparison of tetracycline and age determination with red fox teeth following oral rabies vaccination programs.

    PubMed

    Robardet, Emmanuelle; Demerson, Jean-Michel; Andrieu, Sabrina; Cliquet, Florence

    2012-10-01

    The first European interlaboratory comparison of tetracycline and age determination with red fox (Vulpes vulpes) tooth samples was organized by the European Union Reference Laboratory for rabies. Performance and procedures implemented by member states were compared. These techniques are widely used to monitor bait uptake in European oral rabies vaccination campaigns. A panel of five red fox half-mandibles comprising one weak positive juvenile sample, two positive adult samples, one negative juvenile sample, and one negative adult sample were sent, along with a technical questionnaire, to 12 laboratories participating on a voluntary basis. The results of only three laboratories (25%) were 100% correct. False-negative results were more frequently seen in weak positive juvenile samples (58%) but were infrequent in positive adult samples (4%), probably due to differences in the ease of reading the two groups of teeth. Four laboratories (44%) had correct results for age determination on all samples. Ages were incorrectly identified in both adult and juvenile samples, with 11 and 17% of discordant results, respectively. Analysis of the technical questionnaires in parallel with test results suggested that all laboratories cutting mandible sections between the canine and first premolar obtained false results. All the laboratories using longitudinal rather than transverse sections and those not using a mounting medium also produced false results. Section thickness appeared to affect the results; no mistakes were found in laboratories using sections <150 μm thick. Factors having a potential impact on the success of laboratories were discussed, and recommendations proposed. Such interlaboratory trials underline the importance of using standardized procedures for biomarker detection in oral rabies vaccination campaigns. Several changes can be made to improve analysis quality and increase the comparability of bait uptake frequencies among member states.

  13. Simultaneous determination of nine saponins from Panax notoginseng using HPLC and pressurized liquid extraction.

    PubMed

    Wan, J B; Lai, C M; Li, S P; Lee, M Y; Kong, L Y; Wang, Y T

    2006-04-11

    A HPLC and pressurized liquid extraction (PLE) method was developed for simultaneous determination of nine saponins, including notoginsenoside R1, ginsenoside Rg1, Re, Rf, Rb1, Rc, Rb2, Rb3 and Rd in Panax notoginseng. The analysis was performed on C18 column with water-acetonitrile gradient elution and the investigated saponins were authenticated by comparing retention time and mass spectra with their reference compounds. Several methods including PLE, ultrasonication, soxhlet extraction and immersion were used for sample preparation and their extraction efficiency was compared. The results showed that PLE has the highest extraction efficiency and repeatability, which would be valuable on standardization of sample preparation for quality control of Chinese medicines. The developed HPLC and PLE is an effective approach for simultaneously quantitative determination of sapoinins in P. notoginseng, which could be used for quality control of P. notoginseng and its preparations.

  14. Economic evaluations in pain management: principles and methods.

    PubMed

    Asche, Carl V; Seal, Brian; Jackson, Kenneth C; Oderda, Gary M

    2006-01-01

    This paper describes how investigators may design, conduct, and report economic evaluations of pharmacotherapy for pain and symptom management. Because economic evaluation of therapeutic interventions is becoming increasingly important, there is a need for guidance on how economic evaluations can be optimally conducted. The steps required to conduct an economic evaluation are described to provide this guidance. Economic evaluations require two or more therapeutic interventions to be compared in relation to costs and effects. There are five types of economic evaluations, based on analysis of: (1) cost-effectiveness, (2) cost-utility, (3) cost-minimization, (4) cost-consequence, and (5) cost-benefit analyses. The six required steps are: identify the perspective of the study; identify the alternatives that will be compared; identify the relevant costs and effects; determine how to collect the cost and effect data; determine how to perform calculation for cost and effects data; and determine the manner in which to depict the results and draw comparisons.

  15. Retrieving cloudy atmosphere parameters from RPG-HATPRO radiometer data

    NASA Astrophysics Data System (ADS)

    Kostsov, V. S.

    2015-03-01

    An algorithm for simultaneously determining both tropospheric temperature and humidity profiles and cloud liquid water content from ground-based measurements of microwave radiation is presented. A special feature of this algorithm is that it combines different types of measurements and different a priori information on the sought parameters. The features of its use in processing RPG-HATPRO radiometer data obtained in the course of atmospheric remote sensing experiments carried out by specialists from the Faculty of Physics of St. Petersburg State University are discussed. The results of a comparison of both temperature and humidity profiles obtained using a ground-based microwave remote sensing method with those obtained from radiosonde data are analyzed. It is shown that this combined algorithm is comparable (in accuracy) to the classical method of statistical regularization in determining temperature profiles; however, this algorithm demonstrates better accuracy (when compared to the method of statistical regularization) in determining humidity profiles.

  16. A comparative study of the novel spectrophotometric methods versus conventional ones for the simultaneous determination of Esomeprazole magnesium trihydrate and Naproxen in their binary mixture.

    PubMed

    Lotfy, Hayam M; Amer, Sawsan M; Zaazaa, Hala E; Mostafa, Noha S

    2015-01-01

    Two novel simple, specific, accurate and precise spectrophotometric methods manipulating ratio spectra are developed and validated for simultaneous determination of Esomeprazole magnesium trihydrate (ESO) and Naproxen (NAP) namely; absorbance subtraction and ratio difference. The results were compared to that of the conventional spectrophotometric methods namely; dual wavelength and isoabsorptive point coupled with first derivative of ratio spectra and derivative ratio. The suggested methods were validated in compliance with the ICH guidelines and were successfully applied for determination of ESO and NAP in their laboratory prepared mixtures and pharmaceutical preparation. No preliminary separation steps are required for the proposed spectrophotometeric procedures. The statistical comparison showed that there is no significant difference between the proposed methods and the reported method with respect to both accuracy and precision. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Determination of elastic modulus of ceramics using ultrasonic testing

    NASA Astrophysics Data System (ADS)

    Sasmita, Firmansyah; Wibisono, Gatot; Judawisastra, Hermawan; Priambodo, Toni Agung

    2018-04-01

    Elastic modulus is important material property on structural ceramics application. However, bending test as a common method for determining this property require particular specimen preparation. Furthermore, elastic modulus of ceramics could vary because it depends on porosity content. For structural ceramics industry, such as ceramic tiles, this property is very important. This drives the development of new method to improve effectivity or verification method as well. In this research, ultrasonic testing was conducted to determine elastic modulus of soda lime glass and ceramic tiles. The experiment parameter was frequency of probe (1, 2, 4 MHz). Characterization of density and porosity were also done for analysis. Results from ultrasonic testing were compared with elastic modulus resulted from bending test. Elastic modulus of soda-lime glass based on ultrasonic testing showed excellent result with error 2.69% for 2 MHz probe relative to bending test result. Testing on red and white ceramic tiles were still contained error up to 41% and 158%, respectively. The results for red ceramic tile showed trend that 1 MHz probe gave better accuracy in determining elastic modulus. However, testing on white ceramic tile showed different trend. It was due to the presence of porosity and near field effect.

  18. Landscape approaches for determining the ensemble of folding transition states: Success and failure hinge on the degree of frustration

    NASA Astrophysics Data System (ADS)

    Nymeyer, Hugh; Socci, Nicholas D.; Onuchic, José Nelson

    2000-01-01

    * Department of Physics, University of California at San Diego, La Jolla, CA 92093-0319; and § Center for Studies in Physics and Biology, The Rockefeller University, New York, NY 10021 Edited by R. Stephen Berry, University of Chicago, Chicago, IL, and approved November 5, 1999 (received for review July 2, 1999) We present a method for determining structural properties of the ensemble of folding transition states from protein simulations. This method relies on thermodynamic quantities (free energies as a function of global reaction coordinates, such as the percentage of native contacts) and not on "kinetic" measurements (rates, transmission coefficients, complete trajectories); consequently, it requires fewer computational resources compared with otherapproaches, making it more suited to large and complex models. We explain the theoretical framework that underlies this method and use it to clarify the connection between the experimentally determined Phi value, a quantity determined by the ratio of rate and stability changes due to point mutations, and the average structure of the transition state ensemble. To determine the accuracy of this thermodynamic approach, we apply it to minimalist protein models and compare these results with the ones obtained by using the standard experimental procedure for determining Phi values. We show that the accuracy of both methods depends sensitively on the amount of frustration. In particular, the results are similar when applied to models with minimal amounts of frustration, characteristic of rapid-folding, single-domain globular proteins.

  19. Comparative antianaerobic activities of doripenem determined by MIC and time-kill analysis.

    PubMed

    Credito, Kim L; Ednie, Lois M; Appelbaum, Peter C

    2008-01-01

    Against 447 anaerobe strains, the investigational carbapenem doripenem had an MIC 50 of 0.125 microg/ml and an MIC 90 of 1 microg/ml. Results were similar to those for imipenem, meropenem, and ertapenem. Time-kill studies showed that doripenem had very good bactericidal activity compared to other carbapenems, with 99.9% killing of 11 strains at 2x MIC after 48 h.

  20. Results of the measurement of atmospheric ozone and hydrocarbons in Baden-Wurttemburg

    NASA Technical Reports Server (NTRS)

    Blander, W.; Siegel, D.

    1978-01-01

    Data are presented on the diurnal variations of the levels of ozone, ethylene, ethane, and acetylene. The measurement procedures used are described. Variations in monthly ozone levels are given, and measurements from different stations are compared. Data on the total monthly concentrations of NO and NO2 are compared with similar data for ozone. Problems in determining interrelationships among the concentrations of the various substances are discussed.

  1. Comparative Characteristics Of Coherent And Incoherent Radiation In The Photography Of Ulcer

    NASA Astrophysics Data System (ADS)

    Novikov, V. F.; Paramonov, L. V.

    1985-01-01

    The efficiency of He-Ne laser radiation and incoherent radiation by red light sources with different spectral bandwidths is compared for the endoscopic phototherapy of gastric and duodenal ulcers. Coherent and incoherent radiation is determined to result in the same theraputic effect when doing the treatment of ulcer deseases. The methods of ulcer treatment is suggested with a conventional fibrogastroscope fitted with red glass filter.

  2. [Free crystalline silica: a comparison of methods for its determination in total dust].

    PubMed

    Maciejewska, Aleksandra; Szadkowska-Stańczyk, Irena; Kondratowicz, Grzegorz

    2005-01-01

    The major objective of the study was to compare and investigate the usefulness of quantitative analyses of free crystalline silica (FCS) in the assessment of dust exposure in samples of total dust of varied composition, using three methods: chemical method in common use in Poland; infrared spectrometry; and x-ray powder diffraction. Mineral composition and FCS contents were investigated in 9 laboratory samples of raw materials, materials, and industrial wastes, containing from about 2 to over 80% of crystalline silica and reduced to particles of size corresponding with that of total dust. Sample components were identified using XRD and FT-IR methods. Ten independent determinations of FCS with each of the three study methods were performed in dust samples. An analysis of linear correlation was applied to investigate interrelationship between mean FCS determinations. In analyzed dust samples, along with silica dust there were numerous minerals interfering with silica during the quantitative analysis. Comparison of mean results of FCS determinations showed that the results obtained using the FT-IR method were by 12-13% lower than those obtained with two other methods. However, the differences observed were within the limits of changeability of results associated with their precision and dependence on reference materials used. Assessment of occupational exposure to dusts containing crystalline silica can be performed on the basis of quantitative analysis of FCS in total dusts using each of the compared methods. The FT-IR method is most appropriate for the FCS determination in samples of small amount of silica or collected at low dust concentrations; the XRD method for the analysis of multicomponent samples; and the chemical method in the case of medium and high FCS contents in samples or high concentrations of dusts in the work environment.

  3. Selected problems with boron determination in water treatment processes. Part I: comparison of the reference methods for ICP-MS and ICP-OES determinations.

    PubMed

    Kmiecik, Ewa; Tomaszewska, Barbara; Wątor, Katarzyna; Bodzek, Michał

    2016-06-01

    The aim of the study was to compare the two reference methods for the determination of boron in water samples and further assess the impact of the method of preparation of samples for analysis on the results obtained. Samples were collected during different desalination processes, ultrafiltration and the double reverse osmosis system, connected in series. From each point, samples were prepared in four different ways: the first was filtered (through a membrane filter of 0.45 μm) and acidified (using 1 mL ultrapure nitric acid for each 100 mL of samples) (FA), the second was unfiltered and not acidified (UFNA), the third was filtered but not acidified (FNA), and finally, the fourth was unfiltered but acidified (UFA). All samples were analysed using two analytical methods: inductively coupled plasma mass spectrometry (ICP-MS) and inductively coupled plasma optical emission spectrometry (ICP-OES). The results obtained were compared and correlated, and the differences between them were studied. The results show that there are statistically significant differences between the concentrations obtained using the ICP-MS and ICP-OES techniques regardless of the methods of sampling preparation (sample filtration and preservation). Finally, both the ICP-MS and ICP-OES methods can be used for determination of the boron concentration in water. The differences in the boron concentrations obtained using these two methods can be caused by several high-level concentrations in selected whole-water digestates and some matrix effects. Higher concentrations of iron (from 1 to 20 mg/L) than chromium (0.02-1 mg/L) in the samples analysed can influence boron determination. When iron concentrations are high, we can observe the emission spectrum as a double joined and overlapping peak.

  4. The effect of changing gravity and weightlessness of vasopressin control systems

    NASA Technical Reports Server (NTRS)

    Moran, W. H.

    1972-01-01

    An immunoassay to determine the effects of changing gravity and weightlessness on vasopressin control system is discussed. Seven extracts from persons known to have inappropriate ADH syndrome secondary to pulmonary oat cell cancer were examined. The extracts had previously been subject to bioassay in rats. The intent of the examination was to determine if the vasopressin content could be confirmed immunologically. The results compared favorably with the values obtained by biological assay.

  5. Response of composite plates subjected to acoustic loading

    NASA Technical Reports Server (NTRS)

    Moyer, E. Thomas, Jr.

    1989-01-01

    The objectives of the project were to investigate numerical methodology for the determination of narrowband response in the geometrically nonlinear regime, to determine response characteristics for geometrically nonlinear plates subjected to random loading and to compare the predictions with experiments to be performed at NASA-Langley. The first two objectives were met. The response of composite plates subjected to both narrowband and broadband excitation were studied and the results are presented and discussed.

  6. [Determination of protein by CdS quantum dot fluorometry].

    PubMed

    Hu, Wei-Ping; Jiao, Man; Dong, Xue-Zhi; Wang, Xin

    2011-02-01

    Determination of protein content by fluorometry was carried out. In this experiment, CdS quantum dots (QDs) that have special spectral properties were prepared with sodium hexametaphosphate as stabilizer and mercapto acetic acid as modifier by hydrothermal synthesis method. Based on the increase in fluorescence intensity after CdS reacted with bovine serum albumin (BSA), a new method for the determination of protein was established. Results show that the fluorescence intensity of system has a good linear relationship with the concentration of BSA in the range of 0.001 43-0.250 mg x mL(-1), and the linear equation was F = 5 444.301 03 + 43.327 39c, relation coefficient (r) was 0.996 6, the limit of detection was 0.001 4 mg x mL(-1). The method has been used for the determination of protein in milk and egg, and compared with the standard method (biuret method), and the results were satisfactory.

  7. A comparison of two computer-automated semen analysis instruments for the evaluation of sperm motion characteristics in the stallion.

    PubMed

    Jasko, D J; Lein, D H; Foote, R H

    1990-01-01

    Two commercially available computer-automate semen analysis instruments (CellSoft Automated Semen Analyzer and HTM-2000 Motion Analyzer) were compared for their ability to report similar results based on the analysis of pre-recorded video tapes of extended, motile stallion semen. The determinations of the percentage of motile cells by these instruments were more similar than the comparisons between subjective estimates and either instrument. However, mean values obtained from the same sample may still differ by as much as 30 percentage units between instruments. Instruments varied with regard to the determinations of mean sperm curvilinear velocity and sperm concentration, but mean sperm linearity determinations were similar between the instruments. We concluded that the determinations of sperm motion characteristics by subjective estimation, CellSoft Automated Semen Analyzer, and HTM-2000 Motility Analyzer are often dissimilar, making direct comparisons of results difficult.

  8. Optical and Thermo-optical Properties of Polyimide-Single-Walled Carbon Nanotube Films: Experimental Results and Empirical Equations

    NASA Technical Reports Server (NTRS)

    Smith, Joseph G., Jr.; Connell, John W.; Watson, Kent A.; Danehy, Paul M.

    2005-01-01

    The incorporation of single-walled carbon nanotubes (SWNTs) into the bulk of space environmentally durable polymers at loading levels greater than or equal to 0.05 wt % has afforded thin films with surface and volume resistivities sufficient for electrostatic charge mitigation. However, the optical transparency at 500 nm decreased and the thermo-optical properties (solar absorptivity and thermal emissivity) increased with increaed SWNT loading. These properties were also dependent on film thickness. The absorbance characteristics of the films as a function of SWNT loading and film thickness were measured and determined to follow the classical Beer-Lambert law. Based on these results, an empirical relationship was derived and molar absorptivities determined for both the SWNTs and polymer matrix to provide a predictive approximation of these properties. The molar absorptivity determined for SWNTs dispersed in the polymer was comparable to reported solution determined values for HiPco SWNTs.

  9. Evaluation of trace elements in lung samples from coal miners using neutron activation analysis.

    PubMed

    Saiki, M; Saldiva, P H; Alice, S H

    1999-01-01

    In this study, instrumental neutron activation analysis was applied to the determination of Sc, La, Ce, Nd, Sm, Eu, Tb, Yb, Lu, Hf, Th, and U in lung samples from miners working in coal mines located in the state of Santa Catarina, Brazil. These results were compared to those from a control group constituted of healthy individuals. The results showed that the elements determined exhibit considerable intersubject variability within a single group of individuals and the mean values of concentrations in miners' lungs were higher than those of normal individuals. Lung samples presented U concentrations varying from 11 to 890 micrograms/kg. Therefore, for some samples, the contribution of the uranium fission products in the analysis of La, Ce, Nd, and Sm was considered by determining the interference correction factors. The accuracy of the results was evaluated by analyzing certified reference materials.

  10. Determination of the Parameter Sets for the Best Performance of IPS-driven ENLIL Model

    NASA Astrophysics Data System (ADS)

    Yun, Jongyeon; Choi, Kyu-Cheol; Yi, Jonghyuk; Kim, Jaehun; Odstrcil, Dusan

    2016-12-01

    Interplanetary scintillation-driven (IPS-driven) ENLIL model was jointly developed by University of California, San Diego (UCSD) and National Aeronaucics and Space Administration/Goddard Space Flight Center (NASA/GSFC). The model has been in operation by Korean Space Weather Cetner (KSWC) since 2014. IPS-driven ENLIL model has a variety of ambient solar wind parameters and the results of the model depend on the combination of these parameters. We have conducted researches to determine the best combination of parameters to improve the performance of the IPS-driven ENLIL model. The model results with input of 1,440 combinations of parameters are compared with the Advanced Composition Explorer (ACE) observation data. In this way, the top 10 parameter sets showing best performance were determined. Finally, the characteristics of the parameter sets were analyzed and application of the results to IPS-driven ENLIL model was discussed.

  11. Orbit Determination Accuracy for Comets on Earth-Impacting Trajectories

    NASA Technical Reports Server (NTRS)

    Kay-Bunnell, Linda

    2004-01-01

    The results presented show the level of orbit determination accuracy obtainable for long-period comets discovered approximately one year before collision with Earth. Preliminary orbits are determined from simulated observations using Gauss' method. Additional measurements are incorporated to improve the solution through the use of a Kalman filter, and include non-gravitational perturbations due to outgassing. Comparisons between observatories in several different circular heliocentric orbits show that observatories in orbits with radii less than 1 AU result in increased orbit determination accuracy for short tracking durations due to increased parallax per unit time. However, an observatory at 1 AU will perform similarly if the tracking duration is increased, and accuracy is significantly improved if additional observatories are positioned at the Sun-Earth Lagrange points L3, L4, or L5. A single observatory at 1 AU capable of both optical and range measurements yields the highest orbit determination accuracy in the shortest amount of time when compared to other systems of observatories.

  12. Increased determinism in brain electrical activity occurs in association with multiple sclerosis.

    PubMed

    Carrubba, Simona; Minagar, Alireza; Chesson, Andrew L; Frilot, Clifton; Marino, Andrew A

    2012-04-01

    Increased determinism (decreased complexity) of brain electrical activity has been associated with some brain diseases. Our objective was to determine whether a similar association occurred for multiple sclerosis (MS). Ten subjects with a relapsing-remitting course of MS who were in remission were studied; the controls were age- and gender-matched clinically normal subjects. Recurrence plots were calculated using representative electroencephalogram (EEG) epochs (1-7 seconds) from six derivations; the plots were quantified using the nonlinear variables percent recurrence (%R) and percent determinism (%D). The results were averaged over all derivations for each participant, and the means were compared between the groups. As a linear control procedure the groups were also compared using spectral analysis. The mean±SD of %R for the MS subjects was 6·6±1·3%, compared with 5·1±1·3% in the normal group (P = 0·017), indicating that brain activity in the subjects with MS was less complex, as hypothesized. The groups were not distinguishable using %D or spectral analysis. Taken together with our earlier report that %R could be used to discriminate between MS and normal subjects based on the ability to exhibit evoked potentials, the evidence suggests that complexity analysis of the EEG has potential for development as a diagnostic test for MS.

  13. Determination of electronic stopping powers of 0.05-1 MeV/u 131Xe ions in C-, Ni- and Au-absorbers with calorimetric low temperature detectors

    NASA Astrophysics Data System (ADS)

    Echler, A.; Egelhof, P.; Grabitz, P.; Kettunen, H.; Kraft-Bermuth, S.; Laitinen, M.; Müller, K.; Rossi, M.; Trzaska, W. H.; Virtanen, A.

    2017-01-01

    A new experimental system for precise determination of electronic stopping powers of heavy ions has been set up at the accelerator laboratory of the University of Jyväskylä. The new setup, combining an established B-ToF system and an array of calorimetric low temperature detectors (CLTDs), has been used for the determination of electronic stopping powers of 0.05-1 MeV/u 131Xe ions in carbon, nickel and gold. Thereby advantage of the improved linearity and energy resolution of CLTDs as compared to the previously used ionization detector was taken to reduce energy calibration errors and to increase sensitivity for the energy loss determination, in particular at very low energies. The total uncertainties of 3-4% for C- and Ni-targets, and 5-7% for Au-targets, respectively, are dominated by the target properties, i.e. thickness determination and inhomogeneities. The results are compared to data from literature and to predictions of different theoretical computer codes. In the high energy part of the examined energy range the results are in good agreement with previously published data, while new stopping power data for very heavy ions in different Z2-materials have been obtained at lower energies. Moreover, unexpectedly strong channeling effects for the transmission of the 131Xe ions in thin, partly polycrystalline nickel and gold target foils have been observed and investigated.

  14. Comparison of Thellier-type and multispecimen absolute paleointensities obtained on Miocene to historical lava flows from Lanzarote (Canary Islands, Spain)

    NASA Astrophysics Data System (ADS)

    Calvo-Rathert, M.; Morales, J.; Carrancho, Á.; Gogichaishvili, A.

    2015-12-01

    A paleomagnetic, rock-magnetic and paleointensity study has been carried out on 16 Miocene, Pleistocene, Quaternary and historical lava flows from Lanzarote (Canary Islands, Spain) with two main goals: (i) Compare paleointensity results obtained with two different techniques (Thellier-type and multispecimen) and (ii) obtain new paleointensity data. Initial rock-magnetic experiments on selected samples from each site were carried out to find out the carriers of remanence and to determine their thermal stability and grain size. They included the measurement of thermomagnetic curves, hysteresis parameters and IRM acquisition curves. Mostly reversible but also non-reversible curves were recorded in thermomagnetic experiments, with low-Ti titanomagnetite being the main carrier of remanence in most studied flows. Paleomagnetic analysis showed in most cases a single component and a characteristic component could be determined in 15 flows, all displaying normal-polarity. 83 samples from 13 flows were chosen for paleointensity experiments. In order to compare paleointensity results from exactly the same samples, they were cut into smaller specimens so that in each case a specimen was available to be used for a Thellier-type paleointensity determination, another one for a multispecimen paleointensity experiment and another one for rock-magnetic experiments. Thermomagnetic curves could be therefore measured on all samples subjected to paleointensity experiments. Thellier-type paleointensity determinations were performed with the Coe method between room temperature and 581°C on small (0.9 cm diameter and 1 to 2.5 cm length) specimens. After heating, samples were left cooling down naturally during several hours. Multispecimen paleointensity determinations were carried out using the method of Dekkers and Böhnel. The aforementioned sub-samples were cut into 8 specimens and pressed into salt pellets in order to obtain standard cylindrical specimens. A set of eight experiments was performed using laboratory fields from 10 to 80 μT, with increments of 10 μT. Samples were oriented in such a way that the NRM directions of each sub specimen lay parallel to the axis of the heating chamber and were heated at a temperature of 450°C. Results obtained with both methods are compared and discussed.

  15. Evaluation of seismic testing for quality assurance of lime-stabilized soil.

    DOT National Transportation Integrated Search

    2013-08-01

    This study sought to determine the technical feasibility of using seismic techniques to measure the : laboratory and field seismic modulus of lime-stabilized soils (LSS), and to compare/correlate test results : from bench-top (free-free resonance) se...

  16. Response analysis of an automobile shipping container

    NASA Technical Reports Server (NTRS)

    Hua, L.; Lee, S. H.; Johnstone, B.

    1973-01-01

    The design and development of automobile shipping containers to reduce enroute damage are discussed. Vibration tests were conducted to determine the system structural integrity. A dynamic analysis was made using NASTRAN and the results of the test and the analysis are compared.

  17. 78 FR 78864 - Comparability Determination for Australia: Certain Entity-Level Requirements

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-27

    ... authority to support and enforce its oversight of the registrant. In this context, comparable does not... enforce its oversight of the registrant.\\18\\ \\18\\ 78 FR 45343. In making a comparability determination... effective systemic risk management for the overall swaps market. In making its comparability determination...

  18. Effect of Data Reduction and Fiber-Bridging on Mode I Delamination Characterization of Unidirectional Composites

    NASA Technical Reports Server (NTRS)

    Murri, Gretchen B.

    2011-01-01

    Reliable delamination characterization data for laminated composites are needed for input in analytical models of structures to predict delamination onset and growth. The double-cantilevered beam (DCB) specimen is used to measure fracture toughness, GIc, and strain energy release rate, GImax, for delamination onset and growth in laminated composites under mode I loading. The current study was conducted as part of an ASTM Round Robin activity to evaluate a proposed testing standard for Mode I fatigue delamination propagation. Static and fatigue tests were conducted on specimens of IM7/977-3 and G40-800/5276-1 graphite/epoxies, and S2/5216 glass/epoxy DCB specimens to evaluate the draft standard "Standard Test Method for Mode I Fatigue Delamination Propagation of Unidirectional Fiber-Reinforced Polymer Matrix Composites." Static results were used to generate a delamination resistance curve, GIR, for each material, which was used to determine the effects of fiber-bridging on the delamination growth data. All three materials were tested in fatigue at a cyclic GImax level equal to 90% of the fracture toughness, GIc, to determine the delamination growth rate. Two different data reduction methods, a 2-point and a 7-point fit, were used and the resulting Paris Law equations were compared. Growth rate results were normalized by the delamination resistance curve for each material and compared to the nonnormalized results. Paris Law exponents were found to decrease by 5.4% to 46.2% due to normalizing the growth data. Additional specimens of the IM7/977-3 material were tested at 3 lower cyclic GImax levels to compare the effect of loading level on delamination growth rates. The IM7/977-3 tests were also used to determine the delamination threshold curve for that material. The results show that tests at a range of loading levels are necessary to describe the complete delamination behavior of this material.

  19. Colorectal cancer risk information presented by a nonphysician assistant does not increase screening rates

    PubMed Central

    Wilkins, Thad; Gillies, Ralph A.; Panchal, Pina; Patel, Mittal; Warren, Peter; Schade, Robert R.

    2014-01-01

    Abstract Objective To determine the effectiveness of presenting individualized colorectal cancer (CRC) risk information for increasing CRC screening rates in primary care patients at above-average risk of CRC. Design Randomized controlled trial. Setting Georgia Regents University in Augusta—an academic family medicine clinic in the southeastern United States. Participants Outpatients (50 to 70 years of age) scheduled for routine visits in the family medicine clinic who were determined to be at above-average risk of CRC. Interventions Individualized CRC risk information calculated from the Your Disease Risk tool compared with a standard CRC screening handout. Main outcome measures Intention to complete CRC screening. Secondary measures included the proportions of subjects completing fecal occult blood tests, flexible sigmoidoscopy, and colonoscopy. Results A total of 1147 consecutive records were reviewed to determine eligibility. Overall, 210 (37.7%) of 557 eligible participants were randomized to receive either individualized CRC risk information (prepared by a research assistant) or a standard CRC screening handout. The intervention group had a mean (SD) age of 55.7 (4.8) years and the control group had a mean (SD) age of 55.6 (4.6) years. Two-thirds of the participants in each group were female. The intervention group and the control group were matched by race (P = .40). There was no significant difference between groups for intention to complete CRC screening (P = .58). Overall, 26.7% of the intervention participants and 27.7% of the control participants completed 1 or more CRC screening tests (P = .66). Conclusion Presentation of individualized CRC risk information by a nonphysician assistant as a decision aid did not result in higher CRC screening rates in primary care patients compared with presentation of general CRC screening information. Future research is needed to determine if physician presentation of CRC risk information would result in increased screening rates compared with research assistant presentation. PMID:25122819

  20. Monitoring of microbial communities in anaerobic digestion sludge for biogas optimisation.

    PubMed

    Lim, Jun Wei; Ge, Tianshu; Tong, Yen Wah

    2018-01-01

    This study characterised and compared the microbial communities of anaerobic digestion (AD) sludge using three different methods - (1) Clone library; (2) Pyrosequencing; and (3) Terminal restriction fragment length polymorphism (T-RFLP). Although high-throughput sequencing techniques are becoming increasingly popular and affordable, the reliance of such techniques for frequent monitoring of microbial communities may be a financial burden for some. Furthermore, the depth of microbial analysis revealed by high-throughput sequencing may not be required for monitoring purposes. This study aims to develop a rapid, reliable and economical approach for the monitoring of microbial communities in AD sludge. A combined approach where genetic information of sequences from clone library was used to assign phylogeny to T-RFs determined experimentally was developed in this study. In order to assess the effectiveness of the combined approach, microbial communities determined by the combined approach was compared to that characterised by pyrosequencing. Results showed that both pyrosequencing and clone library methods determined the dominant bacteria phyla to be Proteobacteria, Firmicutes, Bacteroidetes, and Thermotogae. Both methods also found that sludge A and B were predominantly dominated by acetogenic methanogens followed by hydrogenotrophic methanogens. The number of OTUs detected by T-RFLP was significantly lesser than that detected by the clone library. In this study, T-RFLP analysis identified majority of the dominant species of the archaeal consortia. However, many of the more highly diverse bacteria consortia were missed. Nevertheless, the combined approach developed in this study where clone sequences from the clone library were used to assign phylogeny to T-RFs determined experimentally managed to accurately predict the same dominant microbial groups for both sludge A and sludge B, as compared to the pyrosequencing results. Results showed that the combined approach of clone library and T-RFLP accurately predicted the dominant microbial groups and thus is a reliable and more economical way to monitor the evolution of microbial systems in AD sludge. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Real-Time GNSS-Based Attitude Determination in the Measurement Domain.

    PubMed

    Zhao, Lin; Li, Na; Li, Liang; Zhang, Yi; Cheng, Chun

    2017-02-05

    A multi-antenna-based GNSS receiver is capable of providing high-precision and drift-free attitude solution. Carrier phase measurements need be utilized to achieve high-precision attitude. The traditional attitude determination methods in the measurement domain and the position domain resolve the attitude and the ambiguity sequentially. The redundant measurements from multiple baselines have not been fully utilized to enhance the reliability of attitude determination. A multi-baseline-based attitude determination method in the measurement domain is proposed to estimate the attitude parameters and the ambiguity simultaneously. Meanwhile, the redundancy of attitude resolution has also been increased so that the reliability of ambiguity resolution and attitude determination can be enhanced. Moreover, in order to further improve the reliability of attitude determination, we propose a partial ambiguity resolution method based on the proposed attitude determination model. The static and kinematic experiments were conducted to verify the performance of the proposed method. When compared with the traditional attitude determination methods, the static experimental results show that the proposed method can improve the accuracy by at least 0.03° and enhance the continuity by 18%, at most. The kinematic result has shown that the proposed method can obtain an optimal balance between accuracy and reliability performance.

  2. Comparing the ISO-recommended and the cumulative data-reduction algorithms in S-on-1 laser damage test by a reverse approach method

    NASA Astrophysics Data System (ADS)

    Zorila, Alexandru; Stratan, Aurel; Nemes, George

    2018-01-01

    We compare the ISO-recommended (the standard) data-reduction algorithm used to determine the surface laser-induced damage threshold of optical materials by the S-on-1 test with two newly suggested algorithms, both named "cumulative" algorithms/methods, a regular one and a limit-case one, intended to perform in some respects better than the standard one. To avoid additional errors due to real experiments, a simulated test is performed, named the reverse approach. This approach simulates the real damage experiments, by generating artificial test-data of damaged and non-damaged sites, based on an assumed, known damage threshold fluence of the target and on a given probability distribution function to induce the damage. In this work, a database of 12 sets of test-data containing both damaged and non-damaged sites was generated by using four different reverse techniques and by assuming three specific damage probability distribution functions. The same value for the threshold fluence was assumed, and a Gaussian fluence distribution on each irradiated site was considered, as usual for the S-on-1 test. Each of the test-data was independently processed by the standard and by the two cumulative data-reduction algorithms, the resulting fitted probability distributions were compared with the initially assumed probability distribution functions, and the quantities used to compare these algorithms were determined. These quantities characterize the accuracy and the precision in determining the damage threshold and the goodness of fit of the damage probability curves. The results indicate that the accuracy in determining the absolute damage threshold is best for the ISO-recommended method, the precision is best for the limit-case of the cumulative method, and the goodness of fit estimator (adjusted R-squared) is almost the same for all three algorithms.

  3. Comparative atmosphere structure experiment

    NASA Technical Reports Server (NTRS)

    Sommer, S.

    1974-01-01

    Atmospheric structure of outer planets as determined by pressure, temperature, and accelerometers is reviewed and results obtained from the PAET earth entry are given. In order to describe atmospheric structure, entry is divided into two regimes, high and low speed. Acceleration is then measured: from these measurements density is determined as a function of time. The equations of motion are integrated to determine velocity, flight path angle, and altitude as a function of time. Density is then determined as a function of altitude from the previous determinations of density and altitude as a function of time. Hydrostatic equilibrium was assumed to determine pressure as a function of altitude. Finally the equation of space applied to determine temperature as a function of altitude, if the mean molecular weight is known. The mean molecular weight is obtained independently from either the low speed experiment or from the composition experiments.

  4. Re-Evaluation of Development of the TMDL Using Long-Term Monitoring Data and Modeling

    NASA Astrophysics Data System (ADS)

    Squires, A.; Rittenburg, R.; Boll, J.; Brooks, E. S.

    2012-12-01

    Since 1996, 47,979 Total Maximum Daily Loads (TMDLs) have been approved throughout the United States for impaired water bodies. TMDLs are set through the determination of natural background loads for a given water body which then estimate contributions from point and nonpoint sources to create load allocations and determine acceptable pollutant levels to meet water quality standards. Monitoring data and hydrologic models may be used in this process. However, data sets used are often limited in duration and frequency, and model simulations are not always accurate. The objective of this study is to retrospectively look at the development and accuracy of the TMDL for a stream in an agricultural area using long-term monitoring data and a robust modeling process. The study area is the Paradise Creek Watershed in northern Idaho. A sediment TMDL was determined for the Idaho section of Paradise Creek in 1997. Sediment TMDL levels were determined using a short-term data set and the Water Erosion Prediction Project (WEPP) model. Background loads used for the TMDL in 1997 were from pre-agricultural levels, based on WEPP model results. We modified the WEPP model for simulation of saturation excess overland flow, the dominant runoff generation mechanism, and analyzed more than 10 years of high resolution monitoring data from 2001 - 2012, including discharge and total suspended solids. Results will compare background loading and current loading based on present-day land use documented during the monitoring period and compare previous WEPP model results with the modified WEPP model results. This research presents a reevaluation of the TMDL process with recommendations for a more scientifically sound methodology to attain realistic water quality goals.

  5. A rapid spin through oil results in higher cell-associated concentrations of antiretrovirals compared with conventional cell washing

    PubMed Central

    Cory, Theodore J; Winchester, Lee C; Robbins, Brian L; Fletcher, Courtney V

    2015-01-01

    Background: Determination of cell-associated antiretroviral drug concentrations is necessary for research into reservoirs of HIV. Variation exists in cell-associated drug concentrations among research groups. One cause for this may be washing cells during processing. We explored spinning cells through oil to minimize this variability. Methods & results: Raltegravir, atazanavir, darunavir, efavirenz, lopinavir and ritonavir concentrations were assessed in CEM.ss T cells washed with HBSS and oil-spun cells. Oil-spun cells had significantly higher concentrations for all drugs compared with samples washed with HBSS. Conclusion: The decline in cell-associated drug concentrations with saline washes compared with a single spin through oil shows the utility of a spin through oil. Oil centrifugation results in high cell-associated drug concentrations, and can be done in a fast, efficient manner. PMID:26168252

  6. Applying Bayesian Neural Network to determine neutrino incoming direction in reactor neutrino experiments and supernova explosion location by scintillator detectors

    NASA Astrophysics Data System (ADS)

    Xu, W. W.; Xu, Y.; Meng, Y. X.; Wu, B.

    2009-01-01

    In the paper, it is discussed by using Monte-Carlo simulation that the Bayesian Neural Network (BNN) is applied to determine neutrino incoming direction in reactor neutrino experiments and supernova explosion location by scintillator detectors. As a result, compared to the method in ref. [1], the uncertainty on the measurement of the neutrino direction using BNN is significantly improved. The uncertainty on the measurement of the reactor neutrino direction is about 1.0° at the 68.3% C.L., and the one in the case of supernova neutrino is about 0.6° at the 68.3% C.L. . Compared to the method in ref. [1], the uncertainty attainable by using BNN reduces by a factor of about 20. And compared to the Super-Kamiokande experiment (SK), it reduces by a factor of about 8.

  7. Effects of aflatoxin on some haematological parameters and protective effectiveness of esterified glucomannan in Merino rams.

    PubMed

    Dönmez, Nurcan; Dönmez, H H; Keskin, E; Kısadere, İ

    2012-01-01

    The objective of the present study was to evaluate the toxic effects of aflatoxin on some hematological parameters and to determine the preventive effectiveness of added glucomannan. In the study, 32 Merino rams were used, and the rams were separated equally to four groups as control (C), glucomannan (G), glucomannan + aflatoxin (AG), and aflatoxin (A). Erythrocyte, leukocyte count, hemoglobin, and hematocrit levels were decreased in A group compared with the other groups, and there was a reduction in similar parameters in AG group compared to control values. On the other hand, these parameters were tended to increase in AG group compared to A group values. Aflatoxicosis caused the lymphocytopenia and monocytopenia but increased percentage of neutrophil counts. In conclusion, the results determined in the study might be important to demonstrate the effects of aflatoxicosis and glucomannan on some haematological parameters before the clinical symptoms appear.

  8. Understanding the relationship between audiomagnetotelluric data and models, and borehole data in a hydrological environment

    USGS Publications Warehouse

    McPhee, D.K.; Pellerin, L.

    2008-01-01

    Audiomagnetotelluric (AMT) data and resulting models are analyzed with respect to geophysical and geological borehole logs in order to clarify the relationship between the two methodologies of investigation of a hydrological environment. Several profiles of AMT data collected in basins in southwestern United States are being used for groundwater exploration and hydrogeological framework studies. In a systematic manner, the AMT data and models are compared to borehole data by computing the equivalent one-dimensional AMT model and comparing with the two-dimensional (2-D) inverse AMT model. The spatial length is used to determine if the well is near enough to the AMT profile to quantify the relationship between the two datasets, and determine the required resolution of the AMT data and models. The significance of the quality of the borehole data when compared to the AMT data is also examined.

  9. Investigation of Weibull statistics in fracture analysis of cast aluminum

    NASA Technical Reports Server (NTRS)

    Holland, Frederic A., Jr.; Zaretsky, Erwin V.

    1989-01-01

    The fracture strengths of two large batches of A357-T6 cast aluminum coupon specimens were compared by using two-parameter Weibull analysis. The minimum number of these specimens necessary to find the fracture strength of the material was determined. The applicability of three-parameter Weibull analysis was also investigated. A design methodology based on the combination of elementary stress analysis and Weibull statistical analysis is advanced and applied to the design of a spherical pressure vessel shell. The results from this design methodology are compared with results from the applicable ASME pressure vessel code.

  10. Impact of Multi-GNSS Observations on Precise Orbit Determination and Precise Point Positioning Solutions

    NASA Astrophysics Data System (ADS)

    Amiri, N.; Bertiger, W. I.; Lu, W.; Miller, M. A.; David, M. W.; Ries, P.; Romans, L.; Sibois, A. E.; Sibthorpe, A.; Sakumura, C.

    2017-12-01

    Impact of Multi-GNSS Observations on Precise Orbit Determination and Precise Point Positioning Solutions Authors: Nikta Amiri, Willy Bertiger, Wenwen Lu, Mark Miller, David Murphy, Paul Ries, Larry Romans, Carly Sakumura, Aurore Sibois, Anthony Sibthorpe All at the Jet Propulsion Laboratory, California Institute of Technology Multiple Global Navigation Satellite Systems (GNSS) are now in various stages of completion. The four current constellations (GPS, GLONASS, BeiDou, Galileo) comprise more than 80 satellites as of July 2017, with 120 satellites expected to be available when all four constellations become fully operational. We investigate the impact of simultaneous observations to these four constellations on global network precise orbit determination (POD) solutions, and compare them to available sets of orbit and clock products submitted to the Multi-GNSS Experiment (MGEX). Using JPL's GipsyX software, we generate orbit and clock products for the four constellations. The resulting solutions are evaluated based on a number of metrics including day-to-day internal and external orbit and/or clock overlaps and estimated constellation biases. Additionally, we examine estimated station positions obtained from precise point positioning (PPP) solutions by comparing results generated from multi-GNSS and GPS-only orbit and clock products.

  11. Gauging the Impact of Gender Grammaticization in Different Languages: Application of a Linguistic-Visual Paradigm

    PubMed Central

    Sato, Sayaka; Gygax, Pascal M.; Gabriel, Ute

    2016-01-01

    Employing a linguistic-visual paradigm, we investigated whether the grammaticization of gender information impacts readers’ gender representations. French and German were taken as comparative languages, taking into account the male gender bias associated to both languages, as well as the comparative gender biases associated to their plural determiners (French: les [generic] vs. German: die [morphologically feminine]). Bilingual speakers of French and German had to judge whether a pair of facial images representing two men or a man and a woman could represent a gender stereotypical role noun prime (e.g., nurses). The prime was presented in the masculine plural form with or without a plural determiner. Results indicated that the overt grammaticization of the male gender in the masculine form dominated the representation of the role nouns (though interpretable as generic). However, the effect of the determiner was not found, indicating that only gender information associated to a human reference role noun had impacted readers’ representations. The results, discussed in the framework of the thinking-for-speaking hypothesis, demonstrated that linguistic-visual paradigms are well-suited to gauge the impact of both stereotype information and grammaticization when processing role nouns. PMID:26941663

  12. Quantitative determination of ambroxol in tablets by derivative UV spectrophotometric method and HPLC.

    PubMed

    Dinçer, Zafer; Basan, Hasan; Göger, Nilgün Günden

    2003-04-01

    A derivative UV spectrophotometric method for the determination of ambroxol in tablets was developed. Determination of ambroxol in tablets was conducted by using first-order derivative UV spectrophotometric method at 255 nm (n = 5). Standards for the calibration graph ranging from 5.0 to 35.0 microg/ml were prepared from stock solution. The proposed method was accurate with 98.6+/-0.4% recovery value and precise with coefficient of variation (CV) of 1.22. These results were compared with those obtained by reference methods, zero-order UV spectrophotometric method and reversed-phase high-performance liquid chromatography (HPLC) method. A reversed-phase C(18) column with aqueous phosphate (0.01 M)-acetonitrile-glacial acetic acid (59:40:1, v/v/v) (pH 3.12) mobile phase was used and UV detector was set to 252 nm. Calibration solutions used in HPLC were ranging from 5.0 to 20.0 microg/ml. Results obtained by derivative UV spectrophotometric method was comparable to those obtained by reference methods, zero-order UV spectrophotometric method and HPLC, as far as ANOVA test, F(calculated) = 0.762 and F(theoretical) = 3.89, was concerned. Copyright 2003 Elsevier Science B.V.

  13. Microfluidic Flow Injection Analysis with Thermal Lens Microscopic Detection for Determination of NGAL

    NASA Astrophysics Data System (ADS)

    Radovanović, Tatjana; Liu, Mingqiang; Likar, Polona; Klemenc, Matjaž; Franko, Mladen

    2015-06-01

    A combined microfluidic flow injection analysis-thermal lens microscopy (FIA-TLM) system was applied for determination of neutrophil gelatinase-associated lipocalin (NGAL)—a biomarker of acute kidney injury. NGAL was determined following a commercial ELISA assay and transfer of the resulting solution into the FIA-TLM system with a 100 m deep microchannel. At an excitation power of 100 mW, the FIA-TLM provided about seven times lower limits of detection (1.5 pg as compared to a conventional ELISA test, and a sample throughput of six samples per minute, which compares favorably with sample throughput of the microtiter plate reader, which reads 96 wells in about 30 min. Comparison of results for NGAL in plasma samples from healthy individuals and for NGAL dynamics in patients undergoing coronary angiography measured with transmission mode spectrometry on a microtiter plate reader and with FIA-TLM showed good agreement. In addition to improved LOD, the high sensitivity of FIA-TLM offers possibilities of a further reduction of the total reaction time of the NGAL ELISA test by sacrificing some of the sensitivity while reducing the duration of individual incubation steps.

  14. A novel method for sex determination by detecting the number of X chromosomes.

    PubMed

    Nakanishi, Hiroaki; Shojo, Hideki; Ohmori, Takeshi; Hara, Masaaki; Takada, Aya; Adachi, Noboru; Saito, Kazuyuki

    2015-01-01

    A novel method for sex determination, based on the detection of the number of X chromosomes, was established. Current methods, based on the detection of the Y chromosome, can directly identify an unknown sample as male, but female gender is determined indirectly, by not detecting the Y chromosome. Thus, a direct determination of female gender is important because the quality (e.g., fragmentation and amelogenin-Y null allele) of the Y chromosome DNA may lead to a false result. Thus, we developed a novel sex determination method by analyzing the number of X chromosomes using a copy number variation (CNV) detection technique (the comparative Ct method). In this study, we designed a primer set using the amelogenin-X gene without the CNV region as the target to determine the X chromosome copy number, to exclude the influence of the CNV region from the comparative Ct value. The number of X chromosomes was determined statistically using the CopyCaller software with real-time PCR. All DNA samples from participants (20 males, 20 females) were evaluated correctly using this method with 1-ng template DNA. A minimum of 0.2-ng template DNA was found to be necessary for accurate sex determination with this method. When using ultraviolet-irradiated template DNA, as mock forensic samples, the sex of the samples could not be determined by short tandem repeat (STR) analysis but was correctly determined using our method. Thus, we successfully developed a method of sex determination based on the number of X chromosomes. Our novel method will be useful in forensic practice for sex determination.

  15. First Assessment of the Sex Ratio for an East Pacific Green Sea Turtle Foraging Aggregation: Validation and Application of a Testosterone ELISA.

    PubMed

    Allen, Camryn D; Robbins, Michelle N; Eguchi, Tomoharu; Owens, David W; Meylan, Anne B; Meylan, Peter A; Kellar, Nicholas M; Schwenter, Jeffrey A; Nollens, Hendrik H; LeRoux, Robin A; Dutton, Peter H; Seminoff, Jeffrey A

    2015-01-01

    Determining sex ratios of endangered populations is important for wildlife management, particularly species subject to sex-specific threats or that exhibit temperature-dependent sex determination. Sea turtle sex is determined by incubation temperature and individuals lack external sex-based traits until sexual maturity. Previous research utilized serum/plasma testosterone radioimmunoassays (RIA) to determine sex in immature/juvenile sea turtles. However, there has been a growing application of enzyme-linked immunosorbent assay (ELISA) for wildlife endocrinology studies, but no study on sea turtles has compared the results of ELISA and RIA. This study provides the first sex ratio for a threatened East Pacific green sea turtle (Chelonia mydas) foraging aggregation, a critical step for future management of this species. Here, we validate a testosterone ELISA and compare results between RIA and ELISA of duplicate samples. The ELISA demonstrated excellent correspondence with the RIA for providing testosterone concentrations for sex determination. Neither assay proved reliable for predicting the sex of reproductively active females with increased testosterone production. We then applied ELISA to examine the sex ratio of 69 green turtles foraging in San Diego Bay, California. Of 45 immature turtles sampled, sex could not be determined for three turtles because testosterone concentrations fell between the ranges for either sex (females: 4.1-113.1 pg/mL, males: 198.4-2,613.0 pg/mL) and these turtles were not subsequently recaptured to enable sex determination; using a Bayesian model to predict probabilities of turtle sex we predicted all three 'unknowns' were female (> 0.86). Additionally, the model assigned all turtles with their correct sex (if determined at recapture) with 100% accuracy. Results indicated a female bias (2.83F:1M) among all turtles in the aggregation; when focusing only on putative immature turtles the sex ratio was 3.5F:1M. With appropriate validation, ELISA sexing could be applied to other sea turtle species, and serve as a crucial conservation tool.

  16. First Assessment of the Sex Ratio for an East Pacific Green Sea Turtle Foraging Aggregation: Validation and Application of a Testosterone ELISA

    PubMed Central

    Allen, Camryn D.; Robbins, Michelle N.; Eguchi, Tomoharu; Owens, David W.; Meylan, Anne B.; Meylan, Peter A.; Kellar, Nicholas M.; Schwenter, Jeffrey A.; Nollens, Hendrik H.; LeRoux, Robin A.; Dutton, Peter H.; Seminoff, Jeffrey A.

    2015-01-01

    Determining sex ratios of endangered populations is important for wildlife management, particularly species subject to sex-specific threats or that exhibit temperature-dependent sex determination. Sea turtle sex is determined by incubation temperature and individuals lack external sex-based traits until sexual maturity. Previous research utilized serum/plasma testosterone radioimmunoassays (RIA) to determine sex in immature/juvenile sea turtles. However, there has been a growing application of enzyme-linked immunosorbent assay (ELISA) for wildlife endocrinology studies, but no study on sea turtles has compared the results of ELISA and RIA. This study provides the first sex ratio for a threatened East Pacific green sea turtle (Chelonia mydas) foraging aggregation, a critical step for future management of this species. Here, we validate a testosterone ELISA and compare results between RIA and ELISA of duplicate samples. The ELISA demonstrated excellent correspondence with the RIA for providing testosterone concentrations for sex determination. Neither assay proved reliable for predicting the sex of reproductively active females with increased testosterone production. We then applied ELISA to examine the sex ratio of 69 green turtles foraging in San Diego Bay, California. Of 45 immature turtles sampled, sex could not be determined for three turtles because testosterone concentrations fell between the ranges for either sex (females: 4.1–113.1 pg/mL, males: 198.4–2,613.0 pg/mL) and these turtles were not subsequently recaptured to enable sex determination; using a Bayesian model to predict probabilities of turtle sex we predicted all three ‘unknowns’ were female (> 0.86). Additionally, the model assigned all turtles with their correct sex (if determined at recapture) with 100% accuracy. Results indicated a female bias (2.83F:1M) among all turtles in the aggregation; when focusing only on putative immature turtles the sex ratio was 3.5F:1M. With appropriate validation, ELISA sexing could be applied to other sea turtle species, and serve as a crucial conservation tool. PMID:26465620

  17. Determination of the Kwall correction factor for a cylindrical ionization chamber to measure air-kerma in 60Co gamma beams.

    PubMed

    Laitano, R F; Toni, M P; Pimpinella, M; Bovi, M

    2002-07-21

    The factor Kwall to correct for photon attenuation and scatter in the wall of ionization chambers for 60Co air-kerma measurement has been traditionally determined by a procedure based on a linear extrapolation of the chamber current to zero wall thickness. Monte Carlo calculations by Rogers and Bielajew (1990 Phys. Med. Biol. 35 1065-78) provided evidence, mostly for chambers of cylindrical and spherical geometry, of appreciable deviations between the calculated values of Kwall and those obtained by the traditional extrapolation procedure. In the present work an experimental method other than the traditional extrapolation procedure was used to determine the Kwall factor. In this method the dependence of the ionization current in a cylindrical chamber was analysed as a function of an effective wall thickness in place of the physical (radial) wall thickness traditionally considered in this type of measurement. To this end the chamber wall was ideally divided into distinct regions and for each region an effective thickness to which the chamber current correlates was determined. A Monte Carlo calculation of attenuation and scatter effects in the different regions of the chamber wall was also made to compare calculation to measurement results. The Kwall values experimentally determined in this work agree within 0.2% with the Monte Carlo calculation. The agreement between these independent methods and the appreciable deviation (up to about 1%) between the results of both these methods and those obtained by the traditional extrapolation procedure support the conclusion that the two independent methods providing comparable results are correct and the traditional extrapolation procedure is likely to be wrong. The numerical results of the present study refer to a cylindrical cavity chamber like that adopted as the Italian national air-kerma standard at INMRI-ENEA (Italy). The method used in this study applies, however, to any other chamber of the same type.

  18. Determination of aluminium in groundwater samples by GF-AAS, ICP-AES, ICP-MS and modelling of inorganic aluminium complexes.

    PubMed

    Frankowski, Marcin; Zioła-Frankowska, Anetta; Kurzyca, Iwona; Novotný, Karel; Vaculovič, Tomas; Kanický, Viktor; Siepak, Marcin; Siepak, Jerzy

    2011-11-01

    The paper presents the results of aluminium determinations in ground water samples of the Miocene aquifer from the area of the city of Poznań (Poland). The determined aluminium content amounted from <0.0001 to 752.7 μg L(-1). The aluminium determinations were performed using three analytical techniques: graphite furnace atomic absorption spectrometry (GF-AAS), inductively coupled plasma atomic emission spectrometry (ICP-AES) and inductively coupled plasma mass spectrometry (ICP-MS). The results of aluminium determinations in groundwater samples for particular analytical techniques were compared. The results were used to identify the ascent of ground water from the Mesozoic aquifer to the Miocene aquifer in the area of the fault graben. Using the Mineql+ program, the modelling of the occurrence of aluminium and the following aluminium complexes: hydroxy, with fluorides and sulphates was performed. The paper presents the results of aluminium determinations in ground water using different analytical techniques as well as the chemical modelling in the Mineql+ program, which was performed for the first time and which enabled the identification of aluminium complexes in the investigated samples. The study confirms the occurrence of aluminium hydroxy complexes and aluminium fluoride complexes in the analysed groundwater samples. Despite the dominance of sulphates and organic matter in the sample, major participation of the complexes with these ligands was not stated based on the modelling.

  19. Electromagnetic Scattering From a Polygonal Thin Metallic Plate Using Quadrilateral Meshing

    NASA Technical Reports Server (NTRS)

    Deshpande, Manohar D.

    2003-01-01

    The problem of electromagnetic (EM) scattering from irregularly shaped, thin, metallic flat plates in free space is solved using the electric field integral equation (EFIE) approach in conjunction with the method of moments (MoM) with quadrilateral meshing. An irregularly shaped thin plate is discretized into quadrilateral patches and the unknown electric surface current over the plate is expressed in terms of proper basis functions over these patches. The basis functions for the electric surface current density that satisfy the proper boundary conditions on these quadrilateral patches are derived. The unknown surface current density on these quadrilateral patches is determined by setting up and solving the electric field integral equation by the application of the MoM. From the knowledge of the surface current density, the EM scattering from various irregularly shaped plates is determined and compared with the earlier published results. The novelty in the present approach is the use of quadrilateral patches instead of well known and often used triangular patches. The numerical results obtained using the quadrilateral patches compare favorably with measured results.

  20. Secondary emission from dust grains: Comparison of experimental and model results

    NASA Astrophysics Data System (ADS)

    Richterova, I.; Pavlu, J.; Nemecek, Z.; Safrankova, J.; Zilavy, P.

    The motion, coalescence, and other processes in dust clouds are determined by the dust charge. Since dust grains in the space are bombarded by energetic electrons, the secondary emission is an important process contributing to their charge. It is generally expected that the secondary emission yield is related to surface properties of the bombarded body. However, it is well known that secondary emission from small bodies is determined not only by their composition but an effect of dimension can be very important when the penetration depth of primary electrons is comparable with the grain size. It implies that the secondary emission yield can be influenced by the substrate material if the surface layer is thin enough. We have developed a simple Monte Carlo model of secondary emission that was successfully applied on the dust simulants from glass and melanine formaldehyd (MF) resin and matched very well experimental results. In order to check the influence of surface layers, we have modified the model for spheres covered by a layer with different material properties. The results of model simulations are compared with measurements on MF spheres covered by different metals.

  1. Dynamic Structure Factor and Transport Coefficients of a Homogeneously Driven Granular Fluid in Steady State

    NASA Astrophysics Data System (ADS)

    Vollmayr-Lee, Katharina; Zippelius, Annette; Aspelmeier, Timo

    2011-03-01

    We study the dynamic structure factor of a granular fluid of hard spheres, driven into a stationary nonequilibrium state by balancing the energy loss due to inelastic collisions with the energy input due to driving. The driving is chosen to conserve momentum, so that fluctuating hydrodynamics predicts the existence of sound modes. We present results of computer simulations which are based on an event driven algorithm. The dynamic structure factor F (q , ω) is determined for volume fractions 0.05, 0.1 and 0.2 and coefficients of normal restitution 0.8 and 0.9. We observe sound waves, and compare our results for F (q , ω) with the predictions of generalized fluctuating hydrodynamics which takes into account that temperature fluctuations decay either diffusively or with a finite relaxation rate, depending on wave number and inelasticity. We determine the speed of sound and the transport coefficients and compare them to the results of kinetic theory. K.V.L. thanks the Institute of Theoretical Physics, University of Goettingen, for financial support and hospitality.

  2. Differences in CASA output according to the chamber type when analyzing frozen-thawed bull sperm.

    PubMed

    Ibănescu, Iulian; Leiding, Claus; Ciornei, Ştefan Gregore; Roșca, Petru; Sfartz, Ioana; Drugociu, Dan

    2016-03-01

    As demonstrated by some authors, the type of analyzing chamber can greatly influence the results of computer-assisted sperm analysis (CASA). This study aimed to compare three of the disposable chamber types currently available on the market and to determine whether the CASA output may be significantly different among them. The semen from five Fleckvieh bulls was analyzed by CASA using three different disposable chambers: Leja (20μm), MofA (20μm) and Minitube (20μm), at three different time points: immediately after filling the chamber, at 6min, and also at 12min after filling. Sperm concentration was also determined using the Nucleocounter® NC-100™ device and the hemocytometer as standard methods. The results showed higher values in terms of total and progressive sperm motility for MofA compared to the other two chambers immediately after filling (p<0.05), but higher values for Leja and Minitube after 6 and 12min (p<0.05). All three disposable chambers offered lower values for sperm concentration compared to standard methods (Leja: 68.4±4.9×106/mL; MofA: 80.8±9.6×106/mL; Minitube: 67.3±5.4×106/mL; Nucleocounter: 86.5×106/mL; Hemocytometer: 84.0×106/mL). We conclude that for rapid analyses the MofA chambers provide superior results when compared to the other types that we tested. However, when the analysis requires a longer duration, the Minitube type, and especially the Leja type provide a greater degree of confidence. Further, for determining sperm concentration we think that examiners would be more accurate using the Nucleocounter or the hemocytometer and should make use of CASA only when the other methods are not available. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Magnetic field gradients inferred from multi-point measurements of Cluster FGM and EDI

    NASA Astrophysics Data System (ADS)

    Teubenbacher, Robert; Nakamura, Rumi; Giner, Lukas; Plaschke, Ferdinand; Baumjohann, Wolfgang; Magnes, Werner; Eichelberger, Hans; Steller, Manfred; Torbert, Roy

    2013-04-01

    We use Cluster data from fluxgate magnetometer (FGM) and electron drift instrument (EDI) to determine the magnetic field gradients in the near-Earth magnetotail. Here we use the magnetic field data from FGM measurements as well as the gyro-time data of electrons determined from the time of flight measurements of EDI. The results are compared with the values estimated from empirical magnetic field models for different magnetospheric conditions. We also estimated the spin axis offset of FGM based on comparison between EDI and FGM data and discuss the possible effect in determining the current sheet characteristics.

  4. Research to determine the role of gravity in neurosecretory physiology

    NASA Technical Reports Server (NTRS)

    Clemens, L. E.; Life, J. S.

    1972-01-01

    In an effort to determine the effects of gravity in regulating the synthesis, transport, storage, and release of octopeptides from the hypothalamo-neurophypophyseal system, the teleost fresh water fish was studied. A labyrinthectomized fish was subjected to a gravitational orientation of -G sub z for three days. Results show the fish had reduced levels of adenyl cyclose activity in its kidneys when compared to labyrinthectomized and unoperated fish exposed to normal gravitational orientation (+G sub 2) for the same period of time. Efforts were also made to determine the presence of vasopressin in the neurophypophysis and peripheral target organs.

  5. Determination of carrier yields for neutron activation analysis using energy dispersive X-ray spectrometry

    USGS Publications Warehouse

    Johnson, R.G.; Wandless, G.A.

    1984-01-01

    A new method is described for determining carrier yield in the radiochemical neutron activation analysis of rare-earth elements in silicate rocks by group separation. The method involves the determination of the rare-earth elements present in the carrier by means of energy-dispersive X-ray fluorescence analysis, eliminating the need to re-irradiate samples in a nuclear reactor after the gamma ray analysis is complete. Results from the analysis of USGS standards AGV-1 and BCR-1 compare favorably with those obtained using the conventional method. ?? 1984 Akade??miai Kiado??.

  6. In-flight investigation of a rotating cylinder-based structural excitation system for flutter testing

    NASA Technical Reports Server (NTRS)

    Vernon, Lura

    1993-01-01

    A research excitation system was test flown at the NASA Dryden Flight Research Facility on the two-seat F-16XL aircraft. The excitation system is a wingtip-mounted vane with a rotating slotted cylinder at the trailing edge. As the cylinder rotates during flight, the flow is alternately deflected upward and downward through the slot, resulting in a periodic lift force at twice the cylinder's rotational frequency. Flight testing was conducted to determine the excitation system's effectiveness in the subsonic, transonic, and supersonic flight regimes. Primary research objectives were to determine the system's ability to develop adequate force levels to excite the aircraft's structure and to determine the frequency range over which the system could excite structural modes of the aircraft. In addition, studies were conducted to determine optimal excitation parameters, such as sweep duration, sweep type, and energy levels. The results from the exciter were compared with results from atmospheric turbulence excitation at the same flight conditions. The comparison indicated that the vane with a rotating slotted cylinder provides superior results. The results from the forced excitation were of higher quality and had less variation than the results from atmospheric turbulence. The forced excitation data also invariably yielded higher structural damping values than those from the atmospheric turbulence data.

  7. A Comparison of the Age-Spectra from Data Assimilation Models

    NASA Technical Reports Server (NTRS)

    Schoeberl, Mark R.; Douglass, Anne R.; Zhu, Zheng-Xin; Pawson, Steven; Einaudi, Franco (Technical Monitor)

    2002-01-01

    We use kinematic and diabatic back trajectory calculations, driven by winds from a general circulation model (GCM) and two different data assimilation systems (DAS), to compute the age spectrum at three latitudes in the lower stratosphere. The age-spectra are compared to chemical transport model (CTM) calculations, and the mean ages from all of these studies are compared to observations. The age spectra computed using the GCM winds show a reasonably well-isolated tropics in good agreement with observations; however, the age spectra determined from the DAS differ from the GCM spectra. For the diabatic trajectory calculations, the age spectrum is too broad as a result of too much exchange between the tropics and mid-latitudes. The age spectrum determined using the kinematic trajectory calculation is less broad and lacks an age offset; both of these features are due to excessive vertical dispersion of parcels. The tropical and mid-latitude mean age difference between the diabatically and kinematically determined age-spectra is about one year, the former being older. The CTM calculation of the age spectrum using the DAS winds shows the same dispersive characteristics of the kinematic trajectory calculation. These results suggest that the current DAS products will not give realistic trace gas distributions for long integrations; they also help explain why the mean ages determined in a number of previous DAS driven CTM's are too young compared with observations. Finally, we note trajectory-generated age spectra show significant age anomalies correlated with the seasonal cycles, and these anomalies can be linked to year-to-year variations in the tropical heating rate. These anomalies are suppressed in the CTM spectra suggesting that the CTM transport is too diffusive.

  8. Testing the effect of a science-enhanced curriculum on the science achievement and agricultural competency of secondary agricultural education students

    NASA Astrophysics Data System (ADS)

    Haynes, James Christopher

    Scope and Method of Study. The purpose of this study was to determine if a science-enhanced curriculum produced by the Center for Agricultural and Environmental Research and Training (CAERT) taught in a secondary level animal science or horticulture course would improve students' understanding of selected scientific principles significantly, when compared to students who were instructed using a traditional curriculum. A secondary purpose was to determine the effect that the science-enhanced CAERT curriculum would have on students' agricultural knowledge when compared to students who were instructed using a traditional curriculum. The design of the study was ex post facto, causal comparative because no random assignment of the treatment group occurred. Findings and Conclusions. No statistically significant difference was found between the treatment and comparison groups regarding science achievement. However, the mean score of the treatment group was slightly larger than the comparison group indicating a slightly higher achievement level; a "Small" effect size (d = .16) for this difference was calculated. It was determined that a statistically significant difference (p < .05) existed in agriculture competency scores in animal science (p = .001) and horticulture (p = .000) as a result of the treatment. Moreover, this was considered to be a "very large" effect (d = 1.18) in animal science and a "large" effect (d = .92) in horticulture. When considering student achievement in science, this study found that the use of the science-enhanced CAERT curriculum did not result in a statistically significant increase (p < .05) in student performance as determined by the TerraNova3 science proficiency examination. However, students who were instructed using the CAERT curriculum scored better overall than those who were instructed using a "traditional" curriculum.

  9. The Ultimate Pile Bearing Capacity from Conventional and Spectral Analysis of Surface Wave (SASW) Measurements

    NASA Astrophysics Data System (ADS)

    Faizah Bawadi, Nor; Anuar, Shamilah; Rahim, Mustaqqim A.; Mansor, A. Faizal

    2018-03-01

    A conventional and seismic method for determining the ultimate pile bearing capacity was proposed and compared. The Spectral Analysis of Surface Wave (SASW) method is one of the non-destructive seismic techniques that do not require drilling and sampling of soils, was used in the determination of shear wave velocity (Vs) and damping (D) profile of soil. The soil strength was found to be directly proportional to the Vs and its value has been successfully applied to obtain shallow bearing capacity empirically. A method is proposed in this study to determine the pile bearing capacity using Vs and D measurements for the design of pile and also as an alternative method to verify the bearing capacity from the other conventional methods of evaluation. The objectives of this study are to determine Vs and D profile through frequency response data from SASW measurements and to compare pile bearing capacities obtained from the method carried out and conventional methods. All SASW test arrays were conducted near the borehole and location of conventional pile load tests. In obtaining skin and end bearing pile resistance, the Hardin and Drnevich equation has been used with reference strains obtained from the method proposed by Abbiss. Back analysis results of pile bearing capacities from SASW were found to be 18981 kN and 4947 kN compared to 18014 kN and 4633 kN of IPLT with differences of 5% and 6% for Damansara and Kuala Lumpur test sites, respectively. The results of this study indicate that the seismic method proposed in this study has the potential to be used in estimating the pile bearing capacity.

  10. Mapping of compositional properties of coal using isometric log-ratio transformation and sequential Gaussian simulation - A comparative study for spatial ultimate analyses data.

    PubMed

    Karacan, C Özgen; Olea, Ricardo A

    2018-03-01

    Chemical properties of coal largely determine coal handling, processing, beneficiation methods, and design of coal-fired power plants. Furthermore, these properties impact coal strength, coal blending during mining, as well as coal's gas content, which is important for mining safety. In order for these processes and quantitative predictions to be successful, safer, and economically feasible, it is important to determine and map chemical properties of coals accurately in order to infer these properties prior to mining. Ultimate analysis quantifies principal chemical elements in coal. These elements are C, H, N, S, O, and, depending on the basis, ash, and/or moisture. The basis for the data is determined by the condition of the sample at the time of analysis, with an "as-received" basis being the closest to sampling conditions and thus to the in-situ conditions of the coal. The parts determined or calculated as the result of ultimate analyses are compositions, reported in weight percent, and pose the challenges of statistical analyses of compositional data. The treatment of parts using proper compositional methods may be even more important in mapping them, as most mapping methods carry uncertainty due to partial sampling as well. In this work, we map the ultimate analyses parts of the Springfield coal from an Indiana section of the Illinois basin, USA, using sequential Gaussian simulation of isometric log-ratio transformed compositions. We compare the results with those of direct simulations of compositional parts. We also compare the implications of these approaches in calculating other properties using correlations to identify the differences and consequences. Although the study here is for coal, the methods described in the paper are applicable to any situation involving compositional data and its mapping.

  11. A square-wave adsorptive stripping voltammetric method for the determination of Amaranth, a food additive dye.

    PubMed

    Alghamdi, Ahmad H

    2005-01-01

    Square-wave adsorptive stripping voltammetric (AdSV) determinations of trace concentrations of the azo coloring agent Amaranth are described. The analytical methodology used was based on the adsorptive preconcentration of the dye on the hanging mercury drop electrode, followed by initiation of a negative sweep. In a pH 10 carbonate supporting electrolyte, Amaranth gave a well-defined and sensitive AdSV peak at -518 mV. The electroanalytical determination of this azo dye was found to be optimal in carbonate buffer (pH 10) under the following experimental conditions: accumulation time, 120 s; accumulation potential, 0.0 V; scan rate, 600 mV/s; pulse amplitude, 90 mV; and frequency, 50 Hz. Under these optimized conditions the AdSV peak current was proportional over the concentration range 1 x 10(-8)-1.1 x 10(-7) mol/L (r = 0.999) with a detection limit of 1.7 x 10(-9) mol/L (1.03 ppb). This analytical approach possessed enhanced sensitivity, compared with conventional liquid chromatography or spectrophotometry and it was simple and fast. The precision of the method, expressed as the relative standard deviation, was 0.23%, whereas the accuracy, expressed as the mean recovery, was 104%. Possible interferences by several substances usually present as food additive azo dyes (E110, E102), gelatin, natural and artificial sweeteners, preservatives, and antioxidants were also investigated. The developed electroanalyticals method was applied to the determination of Amaranth in soft drink samples, and the results were compared with those obtained by a reference spectrophotometric method. Statistical analysis (paired t-test) of these data showed that the results of the 2 methods compared favorably.

  12. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, M; Finlay, J; Zhu, T

    Purpose: Photosensitizer concentration during photodynamic therapy (PDT) is an important parameter for accurate dosimetry. Fluorescence signal can be used as a measure of photosensitizer concentration. Two methods of data acquisition were compared to an ex vivo study both for in vivo and phantom models. Methods: Fluorescence signal of commonly used photosensitizer benzoporphyrin derivative monoacid ring A (BPD) was obtained in phantoms and mouse tumors using an excitation light of 405 nm. Interstitial fluorescence signal was obtained using a side-cut fiber inserted into the tumor tissue of interest. Using a previously developed multi-fiber probe, tumor surface fluorescence measurements were also collected.more » Signals were calibrated according to optical phantoms with known sensitizer fluorescence. Optical properties for each sample were determined and the influence of different absorption and scattering properties on the fluorescence signals was investigated. Using single value decomposition of the spectra, the sensitizer concentration was determined using the two different measurement geometries. An ex vivo analysis was also performed for tumor samples to determine the sensitizer concentration. Results: The two fluorescence signals obtained from the surface multi-fiber probe and the interstitial measurements were compared and were corresponding for both phantoms and mouse models. The values obtained were comparable to the ex vivo measurements as well. Despite the difference in geometry, the surface probe measurements can still be used as a metric for determining the presence of sensitizer in small volume tumors. Conclusion: The multi-fiber contact probe can be used as a tool to measure fluorescence at the surface of the treatment area for PDT and predict sensitizer concentration throughout the tumor. This is advantageous in that the measurement does not damage any tissue. Future work will include investigating the dependence of these results on intratumor sensitizer distribution.« less

  13. Application of computational models to estimate organ radiation dose in rainbow trout from uptake of molybdenum-99 with comparison to iodine-131.

    PubMed

    Martinez, N E; Johnson, T E; Pinder, J E

    2016-01-01

    This study compares three anatomical phantoms for rainbow trout (Oncorhynchus mykiss) for the purpose of estimating organ radiation dose and dose rates from molybdenum-99 ((99)Mo) uptake in the liver and GI tract. Model comparison and refinement is important to the process of determining accurate doses and dose rates to the whole body and the various organs. Accurate and consistent dosimetry is crucial to the determination of appropriate dose-effect relationships for use in environmental risk assessment. The computational phantoms considered are (1) a geometrically defined model employing anatomically relevant organ size and location, (2) voxel reconstruction of internal anatomy obtained from CT imaging, and (3) a new model utilizing NURBS surfaces to refine the model in (2). Dose Conversion Factors (DCFs) for whole body as well as selected organs of O. mykiss were computed using Monte Carlo modeling and combined with empirical models for predicting activity concentration to estimate dose rates and ultimately determine cumulative radiation dose (μGy) to selected organs after several half-lives of (99)Mo. The computational models provided similar results, especially for organs that were both the source and target of radiation (less than 30% difference between all models). Values in the empirical model as well as the 14 day cumulative organ doses determined from (99)Mo uptake are compared to similar models developed previously for (131)I. Finally, consideration is given to treating the GI tract as a solid organ compared to partitioning it into gut contents and GI wall, which resulted in an order of magnitude difference in estimated dose for most organs. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Absolute rate of the reaction of C l(2P) with methane from 200-500 K

    NASA Technical Reports Server (NTRS)

    Whytock, D. A.; Lee, J. H.; Michael, J. V.; Payne, W. A.; Stief, L. J.

    1976-01-01

    Rate constants for the reaction of atomic chlorine with methane have been measured from 200-500K using the flash photolysis-resonance fluorescence technique. When the results from fourteen equally spaced experimental determinations are plotted in Arrhenius form a definite curvature is noted. The results are compared to previous work and are theoretically discussed.

  15. Transmission of the agent of sheep scrapie to deer results in PrPSc with two distinct molecular profiles

    USDA-ARS?s Scientific Manuscript database

    The purpose of this work was to determine susceptibility of white-tailed deer (WTD) to the agent of sheep scrapie and to compare the resultant PrPSc to that of the original inoculum and chronic wasting disease (CWD). We inoculated WTD by a natural route of exposure (concurrent oral and intranasal (I...

  16. Land use determination by remote sensor analysis

    NASA Technical Reports Server (NTRS)

    Mallon, H. J.; Howard, J. Y.

    1971-01-01

    A land use analysis of 18 selected census tracts in the Metropolitan Washington area using aerial photography was undertaken. A comparison of the results was made with comparable land use data from the Metropolitan Washington Council of Governments' Parcel File, and the results reported. Summary conclusions and recommendations for the use of photo-derived data in land use studies by COG are made.

  17. Fraternities, Sororities and Binge Drinking: Results from a National Study of American Colleges

    ERIC Educational Resources Information Center

    Wechsler, Henry; Kuh, George; Davenport, Andrea E.

    2009-01-01

    The purpose of this study is to compare the drinking and associated behavior of fraternity and sorority members to that of nonmembers. The project is national in scope, and its results can help determine whether public perceptions of alcohol use by students affiliated with Greek social organizations are warranted. This study will also lend some…

  18. Exploring University Students' Expectations and Beliefs about Physics and Physics Learning in a Problem-Based Learning Context

    ERIC Educational Resources Information Center

    Sahin, Mehmet

    2009-01-01

    This paper reports the results of an exploratory study aimed to determine university students' expectations and beliefs in a problem-based introductory physics course, how those expectations compare to that of students in other universities, and change as a result of one semester of instruction. In total, 264 freshmen engineering students of Dokuz…

  19. The Use of Trial-Based Functional Analysis in Public School Classrooms for Two Students with Developmental Disabilities

    ERIC Educational Resources Information Center

    Rispoli, Mandy J.; Davis, Heather S.; Goodwyn, Fara D.; Camargo, Siglia

    2013-01-01

    Analogue functional analyses are a well-researched means of determining behavioral function in research and clinical contexts. However, conducting analogue functional analyses in school settings can be problematic and may lead to inconclusive results. The purpose of this study was to compare the results of a trial-based functional analysis with…

  20. Determination of very low levels of 5-(hydroxymethyl)-2-furaldehyde (HMF) in natural honey: comparison between the HPLC technique and the spectrophotometric white method.

    PubMed

    Truzzi, Cristina; Annibaldi, Anna; Illuminati, Silvia; Finale, Carolina; Rossetti, Monica; Scarponi, Giuseppe

    2012-07-01

    In this work we compared 2 official methods for the determination of HMF in honey, the spectrophotometric White method and the HPLC method (International Honey Commission) for the determination of HMF in unifloral honey and honeydew samples with a very low HMF content (<4 mg/kg), which is the most critical determination in terms of accuracy and precision of methods. In honey solutions, the limits of quantification for HPLC and White methods are 0.83 mg/L and 0.67 mg/L, respectively, and the linearity range is confirmed up to 20 mg/L for the HPLC method and up to 5 mg/L for the White method. In honeys with HMF >5 mg/kg, the molar extinction coefficient is 15369, lower than the literature value of 16830, and should be used for HMF determination. For samples with HMF content in the range 1-4 mg/kg the accuracy of the 2 methods is comparable both for unifloral and honeydew samples, whereas as regards precision, the HPLC method gives better results (3.5% compared with 6.4% for the White method). So, in general, the HPLC method seems to be more appropriate for the determination of HMF in honey in the range 1-4 mg/kg thanks to its greater precision, but for samples with a HMF content of less than 1 mg/kg the analyses are inaccurate for both methods. This work can help governmental and private laboratories that perform food analyses to choose the best method for the determination of HMF at very low levels in unifloral honey and honeydew samples. © 2012 Institute of Food Technologists®

  1. Novel spectrophotometric methods for simultaneous determination of Amlodipine, Valsartan and Hydrochlorothiazide in their ternary mixture

    NASA Astrophysics Data System (ADS)

    Lotfy, Hayam M.; Hegazy, Maha A.; Mowaka, Shereen; Mohamed, Ekram Hany

    2015-04-01

    This work represents a comparative study of two smart spectrophotometric techniques namely; successive resolution and progressive resolution for the simultaneous determination of ternary mixtures of Amlodipine (AML), Hydrochlorothiazide (HCT) and Valsartan (VAL) without prior separation steps. These techniques consist of several consecutive steps utilizing zero and/or ratio and/or derivative spectra. By applying successive spectrum subtraction coupled with constant multiplication method, the proposed drugs were obtained in their zero order absorption spectra and determined at their maxima 237.6 nm, 270.5 nm and 250 nm for AML, HCT and VAL, respectively; while by applying successive derivative subtraction they were obtained in their first derivative spectra and determined at P230.8-246, P261.4-278.2, P233.7-246.8 for AML, HCT and VAL respectively. While in the progressive resolution, the concentrations of the components were determined progressively from the same zero order absorption spectrum using absorbance subtraction coupled with absorptivity factor methods or from the same ratio spectrum using only one divisor via amplitude modulation method can be used for the determination of ternary mixtures using only one divisor where the concentrations of the components are determined progressively. The proposed methods were checked using laboratory-prepared mixtures and were successfully applied for the analysis of pharmaceutical formulation containing the cited drugs. Moreover comparative study between spectrum addition technique as a novel enrichment technique and a well established one namely spiking technique was adopted for the analysis of pharmaceutical formulations containing low concentration of AML. The methods were validated as per ICH guidelines where accuracy, precision and specificity were found to be within their acceptable limits. The results obtained from the proposed methods were statistically compared with the reported one where no significant difference was observed.

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jenkins, T.F.; Thorne, P.G.; Myers, K.F.

    Salting-out solvent extraction (SOE) was compared with cartridge and membrane solid-phase extraction (SPE) for preconcentration of nitroaromatics, nitramines, and aminonitroaromatics prior to determination by reversed-phase high-performance liquid chromatography. The solid phases used were manufacturer-cleaned materials, Porapak RDX for the cartridge method and Empore SDB-RPS for the membrane method. Thirty-three groundwater samples from the Naval Surface Warfare Center, Crane, Indiana, were analyzed using the direct analysis protocol specified in SW846 Method 8330, and the results were compared with analyses conducted after preconcentration using SOE with acetonitrile, cartridge-based SPE, and membrane-based SPE. For high-concentration samples, analytical results from the three preconcentration techniquesmore » were compared with results from the direct analysis protocol; good recovery of all target analytes was achieved by all three pre-concentration methods. For low-concentration samples, results from the two SPE methods were correlated with results from the SOE method; very similar data was obtained by the SOE and SPE methods, even at concentrations well below 1 microgram/L.« less

  3. Optimization of data analysis for the in vivo neutron activation analysis of aluminum in bone.

    PubMed

    Mohseni, H K; Matysiak, W; Chettle, D R; Byun, S H; Priest, N; Atanackovic, J; Prestwich, W V

    2016-10-01

    An existing system at McMaster University has been used for the in vivo measurement of aluminum in human bone. Precise and detailed analysis approaches are necessary to determine the aluminum concentration because of the low levels of aluminum found in the bone and the challenges associated with its detection. Phantoms resembling the composition of the human hand with varying concentrations of aluminum were made for testing the system prior to the application to human studies. A spectral decomposition model and a photopeak fitting model involving the inverse-variance weighted mean and a time-dependent analysis were explored to analyze the results and determine the model with the best performance and lowest minimum detection limit. The results showed that the spectral decomposition and the photopeak fitting model with the inverse-variance weighted mean both provided better results compared to the other methods tested. The spectral decomposition method resulted in a marginally lower detection limit (5μg Al/g Ca) compared to the inverse-variance weighted mean (5.2μg Al/g Ca), rendering both equally applicable to human measurements. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. Analytical methods to characterize heterogeneous raw material for thermal spray process: cored wire Inconel 625

    NASA Astrophysics Data System (ADS)

    Lindner, T.; Bonebeau, S.; Drehmann, R.; Grund, T.; Pawlowski, L.; Lampke, T.

    2016-03-01

    In wire arc spraying, the raw material needs to exhibit sufficient formability and ductility in order to be processed. By using an electrically conductive, metallic sheath, it is also possible to handle non-conductive and/or brittle materials such as ceramics. In comparison to massive wire, a cored wire has a heterogeneous material distribution. Due to this fact and the complex thermodynamic processes during wire arc spraying, it is very difficult to predict the resulting chemical composition in the coating with sufficient accuracy. An Inconel 625 cored wire was used to investigate this issue. In a comparative study, the analytical results of the raw material were compared to arc sprayed coatings and droplets, which were remelted in an arc furnace under argon atmosphere. Energy-dispersive X-ray spectroscopy (EDX) and X-ray fluorescence (XRF) analysis were used to determine the chemical composition. The phase determination was performed by X-ray diffraction (XRD). The results were related to the manufacturer specifications and evaluated in respect to differences in the chemical composition. The comparison between the feedstock powder, the remelted droplets and the thermally sprayed coatings allows to evaluate the influence of the processing methods on the resulting chemical and phase composition.

  5. The use of QSAR methods for determination of n-octanol/water partition coefficient using the example of hydroxyester HE-1

    NASA Astrophysics Data System (ADS)

    Guziałowska-Tic, Joanna

    2017-10-01

    According to the Directive of the European Parliament and of the Council concerning the protection of animals used for scientific purposes, the number of experiments involving the use of animals needs to be reduced. The methods which can replace animal testing include computational prediction methods, for instance, the quantitative structure-activity relationships (QSAR). These methods are designed to find a cohesive relationship between differences in the values of the properties of molecules and the biological activity of a series of test compounds. This paper compares the results of the author's own results of examination on the n-octanol/water coefficient for the hydroxyester HE-1 with those generated by means of three models: Kowwin, MlogP, AlogP. The test results indicate that, in the case of molecular similarity, the highest determination coefficient was obtained for the model MlogP and the lowest root-mean square error was obtained for the Kowwin method. When comparing the mean logP value obtained using the QSAR models with the value resulting from the author's own experiments, it was observed that the best conformity was that recorded for the model AlogP, where relative error was 15.2%.

  6. Upward Flame Propagation and Wire Insulation Flammability: 2006 Round Robin Data Analysis

    NASA Technical Reports Server (NTRS)

    Hirsch, David B.

    2007-01-01

    This viewgraph document reviews test results from tests of different material used for wire insulation for flame propagation and flammability. The presentation focused on investigating data variability both within and between laboratories; evaluated the between-laboratory consistency through consistency statistic h, which indicates how one laboratory s cell average compares with averages from other labs; evaluated the within-laboratory consistency through the consistency statistic k, which is an indicator of how one laboratory s within-laboratory variability compares with the variability of other labs combined; and extreme results were tested to determine whether they resulted by chance or from nonrandom causes (human error, instrument calibration shift, non-adherence to procedures, etc.)

  7. Determination of medical abortion eligibility by women and community health volunteers in Nepal: A toolkit evaluation

    PubMed Central

    Fjerstad, Mary; Basnett, Indira; Neupane, Shailes; Acre, Valerie; Sharma, Sharad Kumar; Jackson, Emily

    2017-01-01

    Objective To determine if pregnant, literate women and female community health volunteers (FCHVs) in Nepal can accurately determine a woman’s eligibility for medical abortion (MA) using a toolkit, compared to comprehensive abortion care (CAC) trained providers. Study design We conducted a prospective diagnostic accuracy study in which women presenting for first trimester abortion, and FCHVs, independently assessed each woman’s eligibility for MA using a modified gestational dating wheel to determine gestational age and a nine-point checklist of MA contraindications or cautions. Ability to determine MA eligibility was compared to experienced CAC-providers using Nepali standard of care. Results Both women (n = 3131) and FCHVs (n = 165) accurately interpreted the wheel 96% of the time, and the eligibility checklist 72% and 95% of the time, respectively. Of the 649 women who reported potential contraindications or cautions on the checklist, 88% misidentified as eligible. Positive predictive value (PPV) of women’s assessment of eligibility based on gestational age was 93% (95% CI 92, 94) compared to CAC-providers’ (n = 47); PPV of the medical contraindications checklist and overall (90% [95% CI 88, 91] and 93% [95% CI 92, 94] respectively) must be interpreted with caution given women’s difficulty using the checklist. PPV of FCHVs’ determinations were 93% (95% CI 92, 94), 90% (95% CI 89,91), and 93% (95% CI 91, 94) respectively. Conclusion Although a promising strategy to assist women and FCHVs to assess MA eligibility, further refinement of the eligibility tools, particularly the checklist, is needed before their widespread use. PMID:28880926

  8. Comparing four non-invasive methods to determine the ventilatory anaerobic threshold during cardiopulmonary exercise testing in children with congenital heart or lung disease.

    PubMed

    Visschers, Naomi C A; Hulzebos, Erik H; van Brussel, Marco; Takken, Tim

    2015-11-01

    The ventilatory anaerobic threshold (VAT) is an important method to assess the aerobic fitness in patients with cardiopulmonary disease. Several methods exist to determine the VAT; however, there is no consensus which of these methods is the most accurate. To compare four different non-invasive methods for the determination of the VAT via respiratory gas exchange analysis during a cardiopulmonary exercise test (CPET). A secondary objective is to determine the interobserver reliability of the VAT. CPET data of 30 children diagnosed with either cystic fibrosis (CF; N = 15) or with a surgically corrected dextro-transposition of the great arteries (asoTGA; N = 15) were included. No significant differences were found between conditions or among testers. The RER = 1 method differed the most compared to the other methods, showing significant higher results in all six variables. The PET-O2 method differed significantly on five of six and four of six exercise variables with the V-slope method and the VentEq method, respectively. The V-slope and the VentEq method differed significantly on one of six exercise variables. Ten of thirteen ICCs that were >0.80 had a 95% CI > 0.70. The RER = 1 method and the V-slope method had the highest number of significant ICCs and 95% CIs. The V-slope method, the ventilatory equivalent method and the PET-O2 method are comparable and reliable methods to determine the VAT during CPET in children with CF or asoTGA. © 2014 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  9. Inter- and Intrarater Reliability Using Different Software Versions of E4D Compare in Dental Education.

    PubMed

    Callan, Richard S; Cooper, Jeril R; Young, Nancy B; Mollica, Anthony G; Furness, Alan R; Looney, Stephen W

    2015-06-01

    The problems associated with intra- and interexaminer reliability when assessing preclinical performance continue to hinder dental educators' ability to provide accurate and meaningful feedback to students. Many studies have been conducted to evaluate the validity of utilizing various technologies to assist educators in achieving that goal. The purpose of this study was to compare two different versions of E4D Compare software to determine if either could be expected to deliver consistent and reliable comparative results, independent of the individual utilizing the technology. Five faculty members obtained E4D digital images of students' attempts (sample model) at ideal gold crown preparations for tooth #30 performed on typodont teeth. These images were compared to an ideal (master model) preparation utilizing two versions of E4D Compare software. The percent correlations between and within these faculty members were recorded and averaged. The intraclass correlation coefficient was used to measure both inter- and intrarater agreement among the examiners. The study found that using the older version of E4D Compare did not result in acceptable intra- or interrater agreement among the examiners. However, the newer version of E4D Compare, when combined with the Nevo scanner, resulted in a remarkable degree of agreement both between and within the examiners. These results suggest that consistent and reliable results can be expected when utilizing this technology under the protocol described in this study.

  10. 21 CFR 201.57 - Specific requirements on content and format of labeling for human prescription drug and...

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... comparative rates of occurrence cannot be reliably determined (e.g., adverse reactions were observed only in... in vivo study designs or results (e.g., drug interaction studies), may be included in this section if...

  11. 21 CFR 201.57 - Specific requirements on content and format of labeling for human prescription drug and...

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... comparative rates of occurrence cannot be reliably determined (e.g., adverse reactions were observed only in... in vivo study designs or results (e.g., drug interaction studies), may be included in this section if...

  12. 21 CFR 201.57 - Specific requirements on content and format of labeling for human prescription drug and...

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... comparative rates of occurrence cannot be reliably determined (e.g., adverse reactions were observed only in... in vivo study designs or results (e.g., drug interaction studies), may be included in this section if...

  13. EMISSIONS FROM BURNING CABINET MAKING SCRAPS

    EPA Science Inventory

    The report gives results of an initial determination of differences in missions when burning ordinary cordwood compared to kitchen cabinet making scraps. he tests were performed in an instrumented woodstove testing laboratory on a stove that simulated units observed in use at a k...

  14. Fatigue Life Methodology for Bonded Composite Skin/Stringer Configurations

    NASA Technical Reports Server (NTRS)

    Krueger, Ronald; Paris, Isabelle L.; OBrien, T. Kevin

    2000-01-01

    A methodology is presented for determining the fatigue life of bonded composite skin/stringer structures based on delamination fatigue characterization data and geometric nonlinear finite element analyses. Results were compared to fatigue tests on stringer flange/skin specimens to verify the approach.

  15. An iwatsubo-based solution for labyrinth seals - comparison with experimental results

    NASA Technical Reports Server (NTRS)

    Childs, D. W.; Scharrer, J. K.

    1984-01-01

    The basic equations are derived for compressible flow in a labyrinth seal. The flow is assumed to be completely turbulent in the circumferential direction where the friction factor is determined by the Blasius relation. Linearized zeroth and first-order perturbation equations are developed for small motion about a centered position by an expansion in the eccentricity ratio. The zeroth-order pressure distribution is found by satisfying the leakage equation while the circumferential velocity distribution is determined by satisfying the momentum equation. The first-order equations are solved by a separation of variables solution. Integration of the resultant pressure distribution along and around the seal defines the reaction force developed by the seal and the corresponding dynamic coefficients. The results of this analysis are compared to published test results.

  16. The role of airfoil geometry in minimizing the effect of insect contamination of laminar flow sections

    NASA Technical Reports Server (NTRS)

    Maresh, J. L.; Bragg, M. B.

    1984-01-01

    A method has been developed to predict the contamination of an airfoil by insects and the resultant performance penalty. Insect aerodynamics have been modeled and the impingement of insects on an airfoil are solved by calculating their trajectories. Upon impact, insect rupture and the resulting height of the debris is determined based on experimental data. A boundary layer analysis is performed to determine which insects cause boundary layer transition and the resultant drag penalty. A contaminated airfoil figure of merit is presented to be used to compare airfoil susceptibility. Results show that the insect contamination effects depend on accretion conditions, airfoil angle of attack and Reynolds number. The importance of the stagnation region to designing airfoils for minimum drag penalties is discussed.

  17. The light output and the detection efficiency of the liquid scintillator EJ-309.

    PubMed

    Pino, F; Stevanato, L; Cester, D; Nebbia, G; Sajo-Bohus, L; Viesti, G

    2014-07-01

    The light output response and the neutron and gamma-ray detection efficiency are determined for liquid scintillator EJ-309. The light output function is compared to those of previous studies. Experimental efficiency results are compared to predictions from GEANT4, MCNPX and PENELOPE Monte Carlo simulations. The differences associated with the use of different light output functions are discussed. Copyright © 2014 Elsevier Ltd. All rights reserved.

  18. Comparative Antianaerobic Activities of Doripenem Determined by MIC and Time-Kill Analysis▿

    PubMed Central

    Credito, Kim L.; Ednie, Lois M.; Appelbaum, Peter C.

    2008-01-01

    Against 447 anaerobe strains, the investigational carbapenem doripenem had an MIC50 of 0.125 μg/ml and an MIC90 of 1 μg/ml. Results were similar to those for imipenem, meropenem, and ertapenem. Time-kill studies showed that doripenem had very good bactericidal activity compared to other carbapenems, with 99.9% killing of 11 strains at 2× MIC after 48 h. PMID:17938185

  19. Determination of aerodynamic sensitivity coefficients in the transonic and supersonic regimes

    NASA Technical Reports Server (NTRS)

    Elbanna, Hesham M.; Carlson, Leland A.

    1989-01-01

    The quasi-analytical approach is developed to compute airfoil aerodynamic sensitivity coefficients in the transonic and supersonic flight regimes. Initial investigation verifies the feasibility of this approach as applied to the transonic small perturbation residual expression. Results are compared to those obtained by the direct (finite difference) approach and both methods are evaluated to determine their computational accuracies and efficiencies. The quasi-analytical approach is shown to be superior and worth further investigation.

  20. THE DETERMINATION OF URANIUM BURNUP IN MWD/TON

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rider, B.F.; Russell, J.L. Jr.; Harris, D.W.

    The mass-spectrometric and radiochemical methods for the determination of burn-up in nuclear fuel are compared for reliability in the range of 5000 to 15,000 Mwd/ton. Neither appears to be clearly superior to the other. Each appears to have an uncertainty of approximately 6 to 8%. It is concluded that both methods of analysis should be employed where reliability is of great concern. Agreement between both methods is the best possible indication of reliable results. (auth)

  1. Plasma Sheet Velocity Measurement Techniques for the Pulsed Plasma Thruster SIMP-LEX

    NASA Technical Reports Server (NTRS)

    Nawaz, Anuscheh; Lau, Matthew

    2011-01-01

    The velocity of the first plasma sheet was determined between the electrodes of a pulsed plasma thruster using three measurement techniques: time of flight probe, high speed camera and magnetic field probe. Further, for time of flight probe and magnetic field probe, it was possible to determine the velocity distribution along the electrodes, as the plasma sheet is accelerated. The results from all three techniques are shown, and are compared for one thruster geometry.

  2. Towards an Effective Health Interventions Design: An Extension of the Health Belief Model

    PubMed Central

    Orji, Rita; Vassileva, Julita; Mandryk, Regan

    2012-01-01

    Introduction The recent years have witnessed a continuous increase in lifestyle related health challenges around the world. As a result, researchers and health practitioners have focused on promoting healthy behavior using various behavior change interventions. The designs of most of these interventions are informed by health behavior models and theories adapted from various disciplines. Several health behavior theories have been used to inform health intervention designs, such as the Theory of Planned Behavior, the Transtheoretical Model, and the Health Belief Model (HBM). However, the Health Belief Model (HBM), developed in the 1950s to investigate why people fail to undertake preventive health measures, remains one of the most widely employed theories of health behavior. However, the effectiveness of this model is limited. The first limitation is the low predictive capacity (R2 < 0.21 on average) of existing HBM’s variables coupled with the small effect size of individual variables. The second is lack of clear rules of combination and relationship between the individual variables. In this paper, we propose a solution that aims at addressing these limitations as follows: (1) we extended the Health Belief Model by introducing four new variables: Self-identity, Perceived Importance, Consideration of Future Consequences, and Concern for Appearance as possible determinants of healthy behavior. (2) We exhaustively explored the relationships/interactions between the HBM variables and their effect size. (3) We tested the validity of both our proposed extended model and the original HBM on healthy eating behavior. Finally, we compared the predictive capacity of the original HBM model and our extended model. Methods: To achieve the objective of this paper, we conducted a quantitative study of 576 participants’ eating behavior. Data for this study were collected over a period of one year (from August 2011 to August 2012). The questionnaire consisted of validated scales assessing the HBM determinants – perceived benefit, barrier, susceptibility, severity, cue to action, and self-efficacy – using 7-point Likert scale. We also assessed other health determinants such as consideration of future consequences, self-identity, concern for appearance and perceived importance. To analyses our data, we employed factor analysis and Partial Least Square Structural Equation Model (PLS-SEM) to exhaustively explore the interaction/relationship between the determinants and healthy eating behavior. We tested for the validity of both our proposed extended model and the original HBM on healthy eating behavior. Finally, we compared the predictive capacity of the original HBM model and our extended model and investigated possible mediating effects. Results: The results show that the three newly added determinants are better predictors of healthy behavior. Our extended HBM model lead to approximately 78% increase (from 40 to 71%) in predictive capacity compared to the old model. This shows the suitability of our extended HBM for use in predicting healthy behavior and in informing health intervention design. The results from examining possible relationships between the determinants in our model lead to an interesting discovery of some mediating relationships between the HBM’s determinants, therefore, shedding light on some possible combinations of determinants that could be employed by intervention designers to increase the effectiveness of their design. Conclusion: Consideration of future consequences, self-identity, concern for appearance, perceived importance, self-efficacy, perceived susceptibility are significant determinants of healthy eating behavior that can be manipulated by healthy eating intervention design. Most importantly, the result from our model established the existence of some mediating relationships among the determinants. The knowledge of both the direct and indirect relationships sheds some light on the possible combination rules. PMID:23569653

  3. Comparison of spectrofluorometric and HPLC methods for the characterization of fecal porphyrins in river otters.

    PubMed

    Taylor, C; Duffy, L K; Plumley, F G; Bowyer, R T

    2000-09-01

    A spectrofluorometric method (B. Grandchamp et al., 1980, Biochem. Biophys. Acta 629, 577-586) developed for the determination of amounts of uroporphyrin I (Uro I), coproporphyrin III (Copro III), and protoporphyrin IX (Proto IX) in skin fibroblasts was compared with a high-performance liquid chromatography (HPLC) method for the analysis of porphyrins in fecal samples of river otters (Lutra canadensis). Heptacarboxylate porphyrin I and coproporphyrin I, two porphyrins determined to be critical in defining the porphyrin profile in fecal samples of river otters with the HPLC method, contributed substantially to the calculation of the concentrations of Uro I and Copro III, respectively, in standard solutions of porphyrins with the spectrofluorometric method. Fluorescent components of the fecal matrix complicated the determination of the concentrations of Uro I, Copro III, and Proto IX with the spectrofluorometric method and resulted in erroneous values for the concentrations of these porphyrins compared with values determined with the HPLC method. These results indicate that the complexity of the sample, particularly with regard to the potential presence of interfering fluorescent compounds, as well as porphyrins additional to Uro I, Copro III, and Proto IX, should be considered prior to the application of the spectrofluorometric method. An alternative HPLC method developed for the rapid characterization of porphyrin profiles in fecal samples of river otters is described. Copyright 2000 Academic Press.

  4. Expanding the Use of a Fluorogenic Method to Determine Activity and Mode of Action of Bacillus thuringiensis Bacteriocins Against Gram-Positive and Gram-Negative Bacteria

    PubMed Central

    de la Fuente-Salcido, Norma M.; Barboza-Corona, J. Eleazar; Espino Monzón, A. N.; Pacheco Cano, R. D.; Balagurusamy, N.; Bideshi, Dennis K.; Salcedo-Hernández, Rubén

    2012-01-01

    Previously we described a rapid fluorogenic method to measure the activity of five bacteriocins produced by Mexican strains of Bacillus thuringiensis against B. cereus 183. Here we standardize this method to efficiently determine the activity of bacteriocins against both Gram-positive and Gram-negative bacteria. It was determined that the crucial parameter required to obtain reproducible results was the number of cells used in the assay, that is, ~4 × 108 cell/mL and ~7 × 108 cell/mL, respectively, for target Gram-positive and Gram-negative bacteria. Comparative analyses of the fluorogenic and traditional well-diffusion assays showed correlation coefficients of 0.88 to 0.99 and 0.83 to 0.99, respectively, for Gram-positive and Gram-negative bacteria. The fluorogenic method demonstrated that the five bacteriocins of B. thuringiensis have bacteriolytic and bacteriostatic activities against all microorganisms tested, including clinically significant bacteria such as Listeria monocytogenes, Proteus vulgaris, and Shigella flexneri reported previously to be resistant to the antimicrobials as determined using the well-diffusion protocol. These results demonstrate that the fluorogenic assay is a more sensitive, reliable, and rapid method when compared with the well-diffusion method and can easily be adapted in screening protocols for bacteriocin production by other microorganisms. PMID:22919330

  5. Salivary analytes in patients with oral squamous cell carcinoma.

    PubMed

    Fuchs, Petra Nola; Rogić, Dunja; Vidović-Juras, Danica; Susić, Mato; Milenović, Aleksandar; Brailo, Vlaho; Boras, Vanja Vucićević

    2011-06-01

    Literature data indicates that measurement of certain salivary constituents might serve as a useful diagnostic/prognostic tool in the patients with oral squamous cell carcinoma (OSCC). In 24 patients with OSCC (60 +/- 2.5 yrs) and in 24 controls (24 +/- 3.7 yrs) we have determined levels of salivary magnesium, calcium, copper, chloride, phosphate, potassium, sodium, total proteins and amylase. Sodium, potassium and chloride were determined by indirect potentiometry whereas copper, magnesium and phosphate were determined by atomic absorption spectrophotometry. Total proteins were determined by pyrogalol colorimetric method. Amylase levels were determined by continued colorimetric method. Statistical analysis was performed by use of chi2 test and Spearman's correlation test. The results of this study indicate that the concentrations of sodium and chloride were significantly elevated in patients with OSCC when compared to the controls. However, level of total protein was significantly decreased when compared to the healthy controls. Furthermore, there was a negative correlation between alcohol consumption and total protein concentration in patients with oral carcinoma. We might conclude that in patients with OSCC increased salivary sodium and chloride might reflect their overall dehydration status due to alcohol consumption rather than consequence of OSCC itself.

  6. Full-field stress determination in photoelasticity with phase shifting technique

    NASA Astrophysics Data System (ADS)

    Guo, Enhai; Liu, Yonggang; Han, Yongsheng; Arola, Dwayne; Zhang, Dongsheng

    2018-04-01

    Photoelasticity is an effective method for evaluating the stress and its spatial variations within a stressed body. In the present study, a method to determine the stress distribution by means of phase shifting and a modified shear-difference is proposed. First, the orientation of the first principal stress and the retardation between the principal stresses are determined in the full-field through phase shifting. Then, through bicubic interpolation and derivation of a modified shear-difference method, the internal stress is calculated from the point with a free boundary along its normal direction. A method to reduce integration error in the shear difference scheme is proposed and compared to the existing methods; the integration error is reduced when using theoretical photoelastic parameters to calculate the stress component with the same points. Results show that when the value of Δx/Δy approaches one, the error is minimum, and although the interpolation error is inevitable, it has limited influence on the accuracy of the result. Finally, examples are presented for determining the stresses in a circular plate and ring subjected to diametric loading. Results show that the proposed approach provides a complete solution for determining the full-field stresses in photoelastic models.

  7. Room temperature structures beyond 1.5 Å by serial femtosecond crystallography

    PubMed Central

    Schmidt, Marius; Pande, Kanupriya; Basu, Shibom; Tenboer, Jason

    2015-01-01

    About 2.5 × 106 snapshots on microcrystals of photoactive yellow protein (PYP) from a recent serial femtosecond crystallographic (SFX) experiment were reanalyzed to maximum resolution. The resolution is pushed to 1.46 Å, and a PYP structural model is refined at that resolution. The result is compared to other PYP models determined at atomic resolution around 1 Å and better at the synchrotron. By comparing subtleties such as individual isotropic temperature factors and hydrogen bond lengths, we were able to assess the quality of the SFX data at that resolution. We also show that the determination of anisotropic temperature factor ellipsoids starts to become feasible with the SFX data at resolutions better than 1.5 Å. PMID:26798807

  8. Contingency designs for attitude determination of TRMM

    NASA Technical Reports Server (NTRS)

    Crassidis, John L.; Andrews, Stephen F.; Markley, F. Landis; Ha, Kong

    1995-01-01

    In this paper, several attitude estimation designs are developed for the Tropical Rainfall Measurement Mission (TRMM) spacecraft. A contingency attitude determination mode is required in the event of a primary sensor failure. The final design utilizes a full sixth-order Kalman filter. However, due to initial software concerns, the need to investigate simpler designs was required. The algorithms presented in this paper can be utilized in place of a full Kalman filter, and require less computational burden. These algorithms are based on filtered deterministic approaches and simplified Kalman filter approaches. Comparative performances of all designs are shown by simulating the TRMM spacecraft in mission mode. Comparisons of the simulation results indicate that comparable accuracy with respect to a full Kalman filter design is possible.

  9. Determination of phagocytosis of /sup 32/P-labeled Staphylococcus aureus by bovine polymorphonuclear leukocytes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dulin, A.M.; Paape, M.J.; Weinland, B.T.

    1984-04-01

    A procedure for the measurement of phagocytosis by bovine polymorphonuclear leukocytes (PMN) of /sup 32/P-labeled Staphylococcus aureus was modified so that a larger number of samples could be compared in a single run, and smaller volumes of sample, PMN, and /sup 32/P-labeled S aureus could be used. Results were highly reproducible, with a coefficient of variation between duplicate determinations of less than or equal to 2%. Lysostaphin was prepared from the supernatant of S staphylolyticus and was compared with a commercially available preparation. Effects of lysostaphin on PMN and influence of incubation media on release of /sup 32/P from /supmore » 32/P-labeled S aureus by lysostaphin were examined.« less

  10. Crowding-facilitated macromolecular transport in attractive micropost arrays.

    PubMed

    Chien, Fan-Tso; Lin, Po-Keng; Chien, Wei; Hung, Cheng-Hsiang; Yu, Ming-Hung; Chou, Chia-Fu; Chen, Yeng-Long

    2017-05-02

    Our study of DNA dynamics in weakly attractive nanofabricated post arrays revealed crowding enhances polymer transport, contrary to hindered transport in repulsive medium. The coupling of DNA diffusion and adsorption to the microposts results in more frequent cross-post hopping and increased long-term diffusivity with increased crowding density. We performed Langevin dynamics simulations and found maximum long-term diffusivity in post arrays with gap sizes comparable to the polymer radius of gyration. We found that macromolecular transport in weakly attractive post arrays is faster than in non-attractive dense medium. Furthermore, we employed hidden Markov analysis to determine the transition of macromolecular adsorption-desorption on posts and hopping between posts. The apparent free energy barriers are comparable to theoretical estimates determined from polymer conformational fluctuations.

  11. Genetic effects of habitat restoration in the Laurentian Great Lakes: an assessment of lake sturgeon origin and genetic diversity

    USGS Publications Warehouse

    Jamie Marie Marranca,; Amy Welsh,; Roseman, Edward F.

    2015-01-01

    Lake sturgeon (Acipenser fulvescens) have experienced significant habitat loss, resulting in reduced population sizes. Three artificial reefs were built in the Huron-Erie corridor in the Great Lakes to replace lost spawning habitat. Genetic data were collected to determine the source and numbers of adult lake sturgeon spawning on the reefs and to determine if the founder effect resulted in reduced genetic diversity. DNA was extracted from larval tail clips and 12 microsatellite loci were amplified. Larval genotypes were then compared to 22 previously studied spawning lake sturgeon populations in the Great Lakes to determine the source of the parental population. The effective number of breeders (Nb) was calculated for each reef cohort. The larval genotypes were then compared to the source population to determine if there were any losses in genetic diversity that are indicative of the founder effect. The St. Clair and Detroit River adult populations were found to be the source parental population for the larvae collected on all three artificial reefs. There were large numbers of contributing adults relative to the number of sampled larvae. There was no significant difference between levels of genetic diversity in the source population and larval samples from the artificial reefs; however, there is some evidence for a genetic bottleneck in the reef populations likely due to the founder effect. Habitat restoration in the Huron-Erie corridor is likely resulting in increased habitat for the large lake sturgeon population in the system and in maintenance of the population's genetic diversity.

  12. Improved method for fluorescence cytometric immunohematology testing.

    PubMed

    Roback, John D; Barclay, Sheilagh; Hillyer, Christopher D

    2004-02-01

    A method for accurate immunohematology testing by fluorescence cytometry (FC) was previously described. Nevertheless, the use of vacuum filtration to wash RBCs and a standard-flow cytometer for data acquisition hindered efforts to incorporate this method into an automated platform. A modified procedure was developed that used low-speed centrifugation of 96-well filter plates for RBC staining. Small-footprint benchtop capillary cytometers (PCA and PCA-96, Guava Technologies, Inc.) were used for data acquisition. Authentic clinical samples from hospitalized patients were tested for ABO group and the presence of D antigen (n = 749) as well as for the presence of RBC alloantibodies (n = 428). Challenging samples with mixed-field reactions and weak antibodies were included. Results were compared to those obtained by column agglutination technology (CAT), and discrepancies were resolved by standard tube methods. Detailed investigations of FC sensitivity and reproducibility were also performed. The modified FC method with the PCA determined the correct ABO group and D type for 98.7 percent of 520 samples, compared to 98.8 percent for CAT (p > 0.05). No-type-determined (NTD) rates were 1.2 percent for both methods. In testing for unexpected alloantibodies, FC determined the correct result for 98.6 percent of 215 samples, compared to 96.3 percent for CAT (p > 0.05). When samples were automatically acquired in the 96-well plate format with the PCA-96, 98.7 percent of 229 samples had correct ABO group and D type determined by FC, compared to 97.4 percent for CAT (p > 0.05). NTD rates were 0.9 and 2.6 percent, respectively. Antibody screens were accurate for 99.1 percent of 213 samples with the PCA-96, compared to 99.5 percent for CAT (p > 0.05). Further investigations demonstrated that FC with the PCA-96 was better than CAT at detecting weak anti-A (p < 0.0001) and alloantibodies. An improved method for FC immunohematology testing has been described. This assay was comparable in accuracy to standard CAT techniques, but had better sensitivity for detecting weak antibodies and was superior in detecting mixed-field reactions (p < 0.005). The FC method demonstrated excellent reproducibility. The compatibility of this assay with the PCA-96 capillary cytometer with plate-handling capabilities should simplify development of a completely automated platform.

  13. The contribution of general and cancer-related variables in explaining physical activity in a breast cancer population 3 weeks to 6 months post-treatment.

    PubMed

    Charlier, Caroline; Van Hoof, Elke; Pauwels, Evelyn; Lechner, Lilian; Spittaels, Heleen; De Bourdeaudhuij, Ilse

    2013-01-01

    Physical activity determinants are subject to change when confronted with the diagnosis of 'cancer' and new cancer-related determinants appear. The aim of the present study is to compare the contribution of cancer-related determinants with more general ones in explaining physical activity 3 weeks to 6 months post-treatment. A theory-based and validated questionnaire was used to identify physical activity levels (total and domain-specific) and associated determinants among 464 breast cancer survivors (aged 18 to 65 years) 3 weeks to 6 months post-treatment. Descriptive analyses showed higher scores for general determinants in comparison with cancer-related determinants. Nevertheless, regression analyses showed that both general and cancer-related determinants explained total and domain-specific physical activity. Self-efficacy, enjoyment, social support, lack of time and lack of company were important general determinants. The perception of returning to normal life, cancer-related barriers (fatigue, lack of energy and physical side effects) and self-efficacy in overcoming these barriers were important cancer-related determinants. Although results differed according to the women's working status and the physical activity domain, general self-efficacy explained most physical activity types in both groups. Comparable with the general population, enhancing breast cancer survivors' self-efficacy in being sufficiently physically active seems to be important in physical activity interventions post-treatment. However, interventions should be tailored to the experienced symptoms and working status of the women. Copyright © 2011 John Wiley & Sons, Ltd.

  14. Oral lactoferrin protects against experimental candidiasis in mice

    PubMed Central

    Velliyagounder, Kabilan; Alsaedi, Wijdan; Alabdulmohsen, Waad; Markowitz, Kenneth; Fine, Daniel H.

    2015-01-01

    Aims To determine the role of lactoferrin in protecting the oral cavities of mice against Candida albicans infection in lactoferrin knockout (LFKO−/−) mice were compared to wild-type (WT) mice. We also determine the protective role of human lactoferrin in the LFKO−/− mice. Methods and Results Antibiotic treated immunosuppressed mice were inoculated with C. albicans (or sham infection) by oral swab and evaluated for the severity of infection after 7 days of infection. To determine the protective role of hLF, we added 0.3% solution of hLF to the drinking water given to some of the mice. CFU count, scoring of lesions and microscopic observations were carried out to determine the severity of infection. LFKO−/−I mice showed a 2 log (P=0.001) higher CFUs of C. albicans in the oral cavity compared to the WTI mice. LFKO−/−I mice given hLF had a 3 log (P=0.001) reduction in CFUs in the oral cavity compared to untreated LFKO−/−I mice. The severity of infection, observed by light microscopy revealed that the tongue of the LFKO−/−I mice showed more white patches compared to WTI and LFKO−/−I+hLF mice. Scanning electron microscopic observation revealed that more filiform papillae were destroyed in LFKO−/−I mice when compared to WTI or LFKO−/−I +hLF mice. Conclusions Human lactoferrin is important in protecting mice from oral C. albicans infection. Administered hLF may be used to prevent C. albicans infection. Significance and Impact of the Study Human lactoferrin, a multifunctional iron-binding glycoprotein can be used as a therapeutic active ingredient in oral health care products against C. albicans. PMID:25319508

  15. Iron in typical and atypical parkinsonism - Mössbauer spectroscopy and MRI studies

    NASA Astrophysics Data System (ADS)

    Kuliński, R.; Bauminger, E. R.; Friedman, A.; Duda, P.; Gałązka-Friedman, J.

    2016-12-01

    Iron may play important role in neurodegeneration. The results of comparative studies of human brain areas (control and pathological) performed by Mössbauer spectroscopy (MS) and magnetic resonance imaging (MRI) techniques are presented. Mössbauer spectroscopy demonstrated a higher concentration of iron in atypical parkinsonism (progressive supranuclear palsy PSP) in the brain areas Substantia Nigra (SN) and Globus Pallidus (GP) involved in this pathological process, compared to control, while the concentration of iron in pathological tissues in typical parkinsonism (Parkinson's disease - PD) did not differ from that in control. These results were compared with the changes in 1/T1 and 1/T2 (T1 and T2 being the relaxation times determined by MRI). A good linear correlation curve was found between the concentration of iron as determined by MS in different areas of control human brains and between 1/T1 and 1/T2. Whereas the finding in PSP-GP (the brain area involved in PSP) also fitted to such a correlation, this was not so for the correlation between pathological SN - the brain area involved in both diseases - and 1/T2, indicating a dependence of T2 on other factors than just the concentration of iron.

  16. [Study on trace elements of lake sediments by ICP-AES and XRF core scanning].

    PubMed

    Cheng, Ai-Ying; Yu, Jun-Qing; Gao, Chun-Liang; Zhang, Li-Sha; He, Xian-Hu

    2013-07-01

    It is the first time to study sediment of Toson lake in Qaidam Basin. Trace elements including Cd, Cr, Cu, Zn and Pb in lake sediment were measured by ICP-AES method, studied and optimized from different resolution methods respectively, and finally determined a optimum pretreatment system for sediment of Toson lake, namely, HCl-HNO3-HF-HClO4-H2O2 system in the proportions of 5 : 5 : 5 : 1 : 1 was determined. At the same time, the data measured by XRF core scanning were compared, the use of moisture content correction method was analyzed, and the influence of the moisture content on the scanning method was discussed. The results showed that, compared to the background value, the contents of Cd and Zn were a little higher, the content of Cr, Cu and Pb was within the background value limits. XRF core scanning was controlled by sediment elements as well as water content in sediment to some extent. The results by the two methods showed a significant positive correlation, with the correlation coefficient up to 0.673-0.925, and they have a great comparability.

  17. Mechanical Properties of Lightweight Concrete Using Recycled Cement-Sand Brick as Coarse Aggregates Replacement

    NASA Astrophysics Data System (ADS)

    Joohari, Ilya; Farhani Ishak, Nor; Amin, Norliyati Mohd

    2018-03-01

    This paper presents the result of replacing natural course aggregate with recycled cement-sand brick (CSB) towards the mechanical properties of concrete. Natural aggregates were used in this study as a control sample to compare with recycled coarse aggregates. This study was also carried to determine the optimum proportion of coarse aggregates replacement to produce lightweight concrete. Besides, this study was conducted to observe the crack and its behaviour development during the mechanical testing. Through this study, four types of concrete mixed were prepared, which were the control sample, 25%, 50% and 75% replacement of CSB. The test conducted to determine the effectiveness of recycled CSB as coarse aggregates replacement in this study were slump test, density measurement, compression test, and flexural test and. The strength of concrete was tested at 7 days and 28 days of curing. From the results obtained, the optimum proportion which produced the highest strength is 25% replacement of recycled CSB. The compressive and flexural strength has decreased by 10%-12% and 4%-34% respectively compared to the control sample. The presence of recycled coarse aggregates in sample has decreased the density of concrete by 0.8%-3% compared to the control sample.

  18. Effect of vermicompost on growth, yield and nutrition status of tomato (Lycopersicum esculentum).

    PubMed

    Azarmi, Rasool; Ziveh, Parviz Sharifi; Satari, Mohammad Reza

    2008-07-15

    An experiment was conducted to determine the effects of vermicompost on growth, yield and fruit quality of tomato (Lycopersicum esculentum var. Super Beta) in a field condition. The experiment was a randomized complete block design with four replications. The different rates of vermicompost (0, 5, 10 and 15 t ha(-1)) was incorporated into the top 15 cm of soil. During experiment period, fruits were harvested twice in a week and total yield were recorded for two months. At the end of experiment, growth characteristics such as leaf number, leaf area and shoot dry weights were determined. The results revealed that addition of vermicompost at rate of 15 t ha(-1) significantly (at p < 0.05) increased growth and yield compared to control. Vermicompost with rate of 15 t ha(-1) increased EC of fruit juice and percentage of fruit dry matter up to 30 and 24%, respectively. The content of K, P, Fe and Zn in the plant tissue increased 55, 73, 32 and 36% compared to untreated plots respectively. The result of our experiment showed addition of vermicompost had significant (p < 0.05) positive effects on growth, yield and elemental content of plant as compared to control.

  19. Simulation of seismic events induced by CO2 injection at In Salah, Algeria

    NASA Astrophysics Data System (ADS)

    Verdon, James P.; Stork, Anna L.; Bissell, Rob C.; Bond, Clare E.; Werner, Maximilian J.

    2015-09-01

    Carbon capture and storage technology has the potential to reduce anthropogenic CO2 emissions. However, the geomechanical response of the reservoir and sealing caprocks must be modelled and monitored to ensure that injected CO2 is safely stored. To ensure confidence in model results, there is a clear need to develop ways of comparing model predictions with observations from the field. In this paper we develop an approach to simulate microseismic activity induced by injection, which allows us to compare geomechanical model predictions with observed microseismic activity. We apply this method to the In Salah CCS project, Algeria. A geomechanical reconstruction is used to simulate the locations, orientations and sizes of pre-existing fractures in the In Salah reservoir. The initial stress conditions, in combination with a history matched reservoir flow model, are used to determine when and where these fractures exceed Mohr-Coulomb limits, triggering failure. The sizes and orientations of fractures, and the stress conditions thereon, are used to determine the resulting micro-earthquake focal mechanisms and magnitudes. We compare our simulated event population with observations made at In Salah, finding good agreement between model and observations in terms of event locations, rates of seismicity, and event magnitudes.

  20. Effect of Melting Iron-Based Alloy Temperature on Carbon Content Observed in Laser-Induced Breakdown Spectroscopy

    NASA Astrophysics Data System (ADS)

    Lin, Xiaomei; Chang, Penghui; Chen, Gehua; Lin, Jingjun; Liu, Ruixiang; Yang, Hao

    2015-11-01

    Our recent work has determined the carbon content in a melting ferroalloy by laser-induced breakdown spectroscopy (LIBS). The emission spectrum of carbon that we obtained in the laboratory is suitable for carbon content determination in a melting ferroalloy but we cannot get the expected results when this method is applied in industrial conditions: there is always an unacceptable error of around 4% between the actual value and the measured value. By comparing the measurement condition in the industrial condition with that in the laboratory, the results show that the temperature of the molten ferroalloy samples to be measured is constant under laboratory conditions while it decreases gradually under industrial conditions. However, temperature has a considerable impact on the measurement of carbon content, and this is the reason why there is always an error between the actual value and the measured value. In this paper we compare the errors of carbon content determination at different temperatures to find the optimum reference temperature range which can fit the requirements better in industrial conditions and, hence, make the measurement more accurate. The results of the comparative analyses show that the measured value of the carbon content in molten state (1620 K) is consistent with the nominal value of the solid standard sample (error within 0.7%). In fact, it is the most accurate measurement in the solid state. Based on this, we can effectively improve the accuracy of measurements in laboratory and can provide a reference standard of temperature for the measurement in industrial conditions. supported by National Natural Science Foundation of China (No. 51374040), and supported by Laser-Induced Plasma Spectroscopy Equipment Development and Application, China (No. 2014YQ120351)

  1. Determination of target detection limits in hyperspectral data using band selection and dimensionality reduction

    NASA Astrophysics Data System (ADS)

    Gross, W.; Boehler, J.; Twizer, K.; Kedem, B.; Lenz, A.; Kneubuehler, M.; Wellig, P.; Oechslin, R.; Schilling, H.; Rotman, S.; Middelmann, W.

    2016-10-01

    Hyperspectral remote sensing data can be used for civil and military applications to robustly detect and classify target objects. High spectral resolution of hyperspectral data can compensate for the comparatively low spatial resolution, which allows for detection and classification of small targets, even below image resolution. Hyperspectral data sets are prone to considerable spectral redundancy, affecting and limiting data processing and algorithm performance. As a consequence, data reduction strategies become increasingly important, especially in view of near-real-time data analysis. The goal of this paper is to analyze different strategies for hyperspectral band selection algorithms and their effect on subpixel classification for different target and background materials. Airborne hyperspectral data is used in combination with linear target simulation procedures to create a representative amount of target-to-background ratios for evaluation of detection limits. Data from two different airborne hyperspectral sensors, AISA Eagle and Hawk, are used to evaluate transferability of band selection when using different sensors. The same target objects were recorded to compare the calculated detection limits. To determine subpixel classification results, pure pixels from the target materials are extracted and used to simulate mixed pixels with selected background materials. Target signatures are linearly combined with different background materials in varying ratios. The commonly used classification algorithms Adaptive Coherence Estimator (ACE) is used to compare the detection limit for the original data with several band selection and data reduction strategies. The evaluation of the classification results is done by assuming a fixed false alarm ratio and calculating the mean target-to-background ratio of correctly detected pixels. The results allow drawing conclusions about specific band combinations for certain target and background combinations. Additionally, generally useful wavelength ranges are determined and the optimal amount of principal components is analyzed.

  2. Blood culture accuracy: discards from central venous catheters in pediatric oncology patients in the emergency department.

    PubMed

    Winokur, Elizabeth J; Pai, Debra; Rutledge, Dana N; Vogel, Kate; Al-Majid, Sadeeka; Marshall, Christine; Sheikewitz, Paul

    2014-07-01

    Lack of specific guidelines regarding collection of blood for culture from central venous catheters (CVCs) has led to inconsistencies in policies among hospitals. Currently, no specific professional or regulatory recommendations exist in relation to using, reinfusing, or discarding blood drawn from CVCs before drawing blood for a culture. Repeated wasting of blood may harm immunocompromised pediatric oncology patients. The purpose of this comparative study was to determine whether differences exist between blood cultures obtained from the first 5 mL of blood drawn from a CVC line when compared with the second 5 mL drawn. During 2009-2011, 62 pediatric oncology patients with CVCs and orders for blood cultures to determine potential sepsis were enrolled during ED visits. Trained study nurses aseptically drew blood and injected the normally discarded first 5 mL and the second specimen (usual care) into separate culture bottles. Specimens were processed in the microbiology laboratory per hospital policy. Positive cultures were evaluated to assess agreement between specimen results and to determine that the identified pathogen was not a contaminant. Out of 186 blood culture pairs, 4.8% demonstrated positive results. In all positive-positive matches, the normal discard specimen contained the same organism as the usual care specimen. In 4 matches, the normally discarded specimen demonstrated notably earlier time to positivity (4 to 31 hours) compared with the usual care specimen, which resulted in earlier initiation of definitive antibiotics. These findings support the accuracy of the specimen that is normally discarded and suggest the need to reconsider its use for blood culture testing. Copyright © 2014 Emergency Nurses Association. Published by Mosby, Inc. All rights reserved.

  3. The Green Bay cesarean section study. III. Falling cesarean birth rates without a formal curtailment program.

    PubMed

    Sandmire, H F; DeMott, R K

    1994-06-01

    We observed decreases in cesarean birth rates at two Green Bay hospitals after the 1990 publication of our first cesarean section study. The purpose of this study was to determine the causes of those decreases and to see whether any outcome changes occurred with lower rates. An additional objective was to determine the perceptions of the 10 physicians regarding the determinants of cesarean birth rates. We compared recent cesarean birth rates (1990 to 1992) to former rates (1986 to 1988) for 10 of the 11 physicians analyzed in our previous studies. Newborn outcomes were analyzed to determine whether variations occur in comparing low to high cesarean rate physician groups. The total, primary, and repeat cesarean birth rates declined from 13.3% to 10.2%, 8.6% to 6.8%, and 4.7% to 3.4%, respectively, between 1986 to 1988 and 1990 to 1992. Variations in cesarean rates occurred among physicians and groups of physicians. Higher cesarean rates did not result in better perinatal outcome. Literature reports, residency training, continuing medical education attendance, and liability risks were the major determinants of cesarean birth as perceived by the 10 physicians in the study. The least important determinant, rated fifteenth of 15, was the national cesarean birth rate.

  4. STK/Lifetime as a Replacement for Heritage Orbital Lifetime Software

    NASA Technical Reports Server (NTRS)

    Dove, Edwin

    2004-01-01

    The Flight Dynamics Analysis Branch (FDAB) of NASNGSFC is tasked with determining the orbital lifetime of several developmental and operational satellites, which include the Hubble Space Telescope. A DOS based program developed by the FDAB many years ago, called PC Lifetime, is used to determine a satellite s lifetime and could soon be in need of a replacement. STK s Lifetime Object Tool is a possible candidate. Due to the reduced support of the PC Lifetime program, and the growing incompatibility of older programs with new operating systems, a comparative analysis was done to determine if STWLifetime could meet the stringent requirements that were laid before it. The use of highly accurate numerical propagators such as STK s High Precision Orbit Propagator ( OP) and the Goddard Trajectory Determination System (GTDS) provided a basis on which to compare STWLifetime s results. Several test cases were run, but the main four test cases would determine whether or not STWLifetime could be PC- Lifetime s replacement. These four cases include a geotransfer orbit, two circular LEOS, and a Poiar LEO. Following rigorous testmg procedures, a conclusion will be determined. STK has proved to be a versatile program on many satellite missions and the FDAB has high hopes that it can pass FDAB s requirements for orbital lifetime prediction.

  5. Assessment of a solid-phase reagent for urinary specific gravity determination.

    PubMed

    Chu, S Y; Sparks, D

    1984-02-01

    We have compared the specific gravity (S.G.) determined by the N-Multistix method with that obtained from the Total Solids (TS) meter. Overall, 88.7% of the specific gravity results obtained with the reagent strip method were within 0.005 of those obtained with the TS meter. There was a good correlation between the methods and there was no bias for the group means obtained by either method. A good correlation was also found between the S.G. on the strip and osmolality (correlation coefficient of 0.955). The results obtained with the reagent strip for urinary specific gravity therefore appear acceptable for routine laboratory purposes.

  6. A study of autonomous satellite navigation methods using the global positioning satellite system

    NASA Technical Reports Server (NTRS)

    Tapley, B. D.

    1980-01-01

    Special orbit determination algorithms were developed to accommodate the size and speed limitations of on-board computer systems of the NAVSTAR Global Positioning System. The algorithms use square root sequential filtering methods. A new method for the time update of the square root covariance matrix was also developed. In addition, the time update method was compared with another square root convariance propagation method to determine relative performance characteristics. Comparisions were based on the results of computer simulations of the LANDSAT-D satellite processing pseudo range and pseudo range-rate measurements from the phase one GPS. A summary of the comparison results is presented.

  7. Simulator for concurrent processing data flow architectures

    NASA Technical Reports Server (NTRS)

    Malekpour, Mahyar R.; Stoughton, John W.; Mielke, Roland R.

    1992-01-01

    A software simulator capability of simulating execution of an algorithm graph on a given system under the Algorithm to Architecture Mapping Model (ATAMM) rules is presented. ATAMM is capable of modeling the execution of large-grained algorithms on distributed data flow architectures. Investigating the behavior and determining the performance of an ATAMM based system requires the aid of software tools. The ATAMM Simulator presented is capable of determining the performance of a system without having to build a hardware prototype. Case studies are performed on four algorithms to demonstrate the capabilities of the ATAMM Simulator. Simulated results are shown to be comparable to the experimental results of the Advanced Development Model System.

  8. Cod Fractions In Mechanical-Biological Wastewater Treatment Plant

    NASA Astrophysics Data System (ADS)

    Płuciennik-Koropczuk, Ewelina; Jakubaszek, Anita; Myszograj, Sylwia; Uszakiewicz, Sylwia

    2017-03-01

    The paper presents results of studies concerning the designation of COD fraction in the raw, mechanically treated and biologically treated wastewater. The test object was a wastewater treatment plant with the output of over 20,000 PE. The results were compared with data received in the ASM models. During investigation following fractions of COD were determined: dissolved non-biodegradable SI, dissolved easily biodegradable SS, in organic suspension slowly degradable XS and in organic suspension non-biodegradable XI. Methodology for determining the COD fraction was based on the guidelines ATV-A 131. The real percentage of each fraction in total COD in raw wastewater are different from data received in ASM models.

  9. Colorimetric determination of cyanide liberated from apricot kernels.

    PubMed

    Egli, K L

    1977-07-01

    A simple colorimetric method is described for determining the quantity of hydrogen cyanide produced by the spontaneous decomposition of amygdalin in apricot kernels. The evolved cyanide is collected in sodium hydroxide solution and assayed colorimetrically by reaction with picric acid. Results for duplicate assays, 3.02 and 3.06 mg CN-/g, compare well with those obtained by AOAC method 26.115 which specifies steam distillation and silver nitrate titration; results for triplicate assays were 3.02, 3.03, and 3.08 mg CN-/g by the latter. Recovery of cyanide from potassium cyanide at a level equivalent to 243 microgram CN-/g was 101.0%.

  10. A general model for memory interference in a multiprocessor system with memory hierarchy

    NASA Technical Reports Server (NTRS)

    Taha, Badie A.; Standley, Hilda M.

    1989-01-01

    The problem of memory interference in a multiprocessor system with a hierarchy of shared buses and memories is addressed. The behavior of the processors is represented by a sequence of memory requests with each followed by a determined amount of processing time. A statistical queuing network model for determining the extent of memory interference in multiprocessor systems with clusters of memory hierarchies is presented. The performance of the system is measured by the expected number of busy memory clusters. The results of the analytic model are compared with simulation results, and the correlation between them is found to be very high.

  11. Viscoelastic properties of elastomeric materials for O-ring applications

    NASA Technical Reports Server (NTRS)

    Bower, Mark V.

    1989-01-01

    Redesign of the Space Shuttle Solid Rocket Booster necessitated re-evaluation of the material used in the field joint O-ring seals. This research project was established to determine the viscoelastic characteristics of five candidate materials. The five materials are: two fluorocarbon compounds, two nitrile compounds, and a silicon compound. The materials were tested in a uniaxial compression test to determine the characteristic relaxation functions. These tests were performed at five different temperatures. A master material curve was developed for each material from the experimental data. The results of this study are compared to tensile relaxation tests. Application of these results to the design analysis is discussed in detail.

  12. Simultaneous determination of iron, cadmium, zinc, copper, nickel, lead, and uranium in seawater by stable isotope dilution spark source mass spectrometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mykytiuk, A.P.; Russell, D.S.; Sturgeon, R.E.

    Trace concentrations (ng/mL) of Fe, Cd, Zn, Cu, Ni, Pb, U, and Co have been determined in seawater by stable isotope dilution spark source mass spectrometry. The seawater samples were preconcentrated on the ion exchanger Chelex-100 and the concentrate was evaporated on a graphite or silver electrode. The results are compared with those obtained by graphite furnace atomic absorption spectrometry and inductively coupled plasma emission spectrometry. The technique avoids the use of calibration standards and is capable of producing results in cases where the analyte is only partially recovered. 2 tables.

  13. Modeling aluminum-lithium alloy welding characteristics

    NASA Technical Reports Server (NTRS)

    Bernstein, Edward L.

    1996-01-01

    The purpose of this project was to develop a finite element model of the heat-affected zone in the vicinity of a weld line on a plate in order to determine an accurate plastic strain history. The resulting plastic strain increments calculated by the finite element program were then to be used to calculate the measure of damage D. It was hoped to determine the effects of varying welding parameters, such as beam power, efficiency, and weld speed, and the effect of different material properties on the occurrence of microfissuring. The results were to be compared first to the previous analysis of Inconel 718, and then extended to aluminum 2195.

  14. "Every shut eye, ain't sleep": The role of racism-related vigilance in racial/ethnic disparities in sleep difficulty.

    PubMed

    Hicken, Margaret T; Lee, Hedwig; Ailshire, Jennifer; Burgard, Sarah A; Williams, David R

    2013-06-01

    Although racial/ethnic disparities in health have been well-characterized in biomedical, public health, and social science research, the determinants of these disparities are still not well-understood. Chronic psychosocial stress related specifically to the American experience of institutional and interpersonal racial discrimination may be an important determinant of these disparities, as a growing literature in separate scientific disciplines documents the adverse health effects of stress and the greater levels of stress experienced by non-White compared to White Americans. However, the empirical literature on the importance of stress for health and health disparities specifically due to racial discrimination, using population-representative data, is still small and mixed. In this paper, we explore the association between a novel measure of racially-salient chronic stress - "racism-related vigilance" - and sleep difficulty. We found that, compared to the White adults in our sample, Black (but not Hispanic) adults reported greater levels of vigilance. This vigilance was positively associated with sleep difficulty to similar degrees for all racial/ethnic groups in our sample (White, Black, Hispanic). Black adults reported greater levels of sleep difficulty compared to White adults. This disparity was slightly attenuated after adjustment for education and income. However, this disparity was completely attenuated after adjustment for racism-related vigilance. We found similar patterns of results for Hispanic compared to White adults, however, the disparities in sleep difficulty were smaller and not statistically significant. Because of the importance of sleep quality to health, our results suggest that the anticipation of and perseveration about racial discrimination is an important determinant of racial disparities in health.

  15. Evidence HDAC9 genetic variant associated with ischaemic stroke increases risk via promoting carotid atherosclerosis

    PubMed Central

    Markus, Hugh S; Mäkelä, Kari-Matti; Bevan, Steve; Raitoharju, Emma; Oksala, Niku; Bis, Joshua C.; O’Donnell, Chris; Hainsworth, Atticus; Lehtimäki, Terho

    2014-01-01

    Background and purpose A novel association between a single nucleotide polymorphism (SNP) on chromosome 7p21.1 and large vessel ischaemic stroke, was recently identified. The most likely underlying gene is histone deacetylase 9 (HDAC9). The mechanism by which HDAC9 increases stroke risk is not clear; both vascular and neuronal mechanisms have been proposed. Methods We determined whether the lead SNPs were associated with asymptomatic carotid plaque (N=25179) and carotid intima-media thickness (N=31210) detected by carotid ultrasound in a meta-analysis of population based and community cohorts. Immunohistochemistry was used to determine whether HDAC9 was expressed in healthy human cerebral and systemic arteries. In the Tampere Vascular Study we determined whether HDAC9 mRNA expression was altered in carotid (N=29), abdominal aortic (N=15) and femoral (N=24) atherosclerotic plaques compared with control (left internal thoracic, N=28) arteries. Results Both SNPs (rs11984041 and rs2107595) were associated with common carotid IMT (rs2107595 p=0.0018) and with presence of carotid plaque (rs2107595 p=0.0022). In both cerebral and systemic arteries, HDAC9 labelling was seen in nuclei and cytoplasm of vascular smooth muscle cells, and in endothelial cells. HDAC9 expression was upregulated in carotid plaques compared to left internal thoracic controls (p=0.00000103). It was also up-regulated in aortic and femoral plaques compared to controls, with mRNA expression increased in carotid compared with femoral plaques (p=0.0038). Conclusions Our results are consistent with the 7p21.1 association acting via promoting atherosclerosis, and consistent with alterations in HDAC9 expression mediating this increased risk. Further studies in experimental models are required to confirm this link. PMID:23449258

  16. “Every shut eye, ain’t sleep”1: The role of racism-related vigilance in racial/ethnic disparities in sleep difficulty

    PubMed Central

    Lee, Hedwig; Ailshire, Jennifer; Burgard, Sarah A.; Williams, David R.

    2013-01-01

    Although racial/ethnic disparities in health have been well-characterized in biomedical, public health, and social science research, the determinants of these disparities are still not well-understood. Chronic psychosocial stress related specifically to the American experience of institutional and interpersonal racial discrimination may be an important determinant of these disparities, as a growing literature in separate scientific disciplines documents the adverse health effects of stress and the greater levels of stress experienced by non-White compared to White Americans. However, the empirical literature on the importance of stress for health and health disparities specifically due to racial discrimination, using population-representative data, is still small and mixed. In this paper, we explore the association between a novel measure of racially-salient chronic stress – “racism-related vigilance” – and sleep difficulty. We found that, compared to the White adults in our sample, Black (but not Hispanic) adults reported greater levels of vigilance. This vigilance was positively associated with sleep difficulty to similar degrees for all racial/ethnic groups in our sample (White, Black, Hispanic). Black adults reported greater levels of sleep difficulty compared to White adults. This disparity was slightly attenuated after adjustment for education and income. However, this disparity was completely attenuated after adjustment for racism-related vigilance. We found similar patterns of results for Hispanic compared to White adults, however, the disparities in sleep difficulty were smaller and not statistically significant. Because of the importance of sleep quality to health, our results suggest that the anticipation of and perseveration about racial discrimination is an important determinant of racial disparities in health. PMID:23894254

  17. Dilute Russel Viper Venom Time analysis in a Haematology Laboratory: An audit.

    PubMed

    Kruger, W; Meyer, P W A; Nel, J G

    2018-04-17

    To determine whether the current set of evaluation criteria used for dilute Russel Viper Venom Time (dRVVT) investigations in the routine laboratory meet expectation and identify possible shortcomings. All dRVVT assays requested from January 2015 to December 2015 were appraised in this cross-sectional study. The raw data panels were compared with the new reference interval, established in 2016, to determine the sequence of assays that should have been performed. The interpretive comments were audited, and false-negative reports identified. Interpretive comments according to three interpretation guidelines were compared. The reagent cost per assay was determined, and reagent cost wastage, due to redundant tests, was calculated. Only ~9% of dRVVT results authorized during 2015 had an interpretive comment included in the report. ~15% of these results were false-negative interpretations. There is a significant statistical difference in interpretive comments between the three interpretation methods. Redundant mixing tests resulted in R 7477.91 (~11%) reagent cost wastage in 2015. We managed to demonstrate very evident deficiencies in our own practice and managed to establish a standardized workflow that will potentially render our service more efficient and cost effective, aiding clinicians in making improved treatment decisions and diagnoses. Furthermore, it is essential that standard operating procedures be kept up to date and executed by all staff in the laboratory. © 2018 John Wiley & Sons Ltd.

  18. The indirect fluorescent antibody technique as a method for detecting antibodies in aborted fetuses.

    PubMed Central

    Miller, R B; Wilkie, B N

    1979-01-01

    In this investigation the indirect fluorescent antibody technique was used to titrate antibodies in bovine sera to parainfluenza 3, infectious bovine rhinotracheitis virus and bovine viral diarrhea virus. These results were compared to those determined on the same samples by hemagglutination inhibition for parainfluenza 3 virus and serum neutralization for bovine virus diarrhea and infectious bovine rhinotracheitis virus. The results of the serological methods agreed closely. The indirect fluorescent antibody technique is a rapid and sensitive method for detecting antibodies and the procedure lends itself to use in diagnostic laboratories. In addition to the above viruses the presence or absence of antibodies to bovine coronavirus and bovine adenovirus 3 were determined by the indirect fluorescent antibody technique in thoracic fluids from 100 aborted fetuses and 50 nonaborted fetuses. Results on these samples were not compared to hemagglutination inhibition or serum neutralization as the condition of fluid samples from aborted fetuses renders interpretation of such tests unreliable. Antibodies to one or more viruses were detected in 30 of the 100 aborted fetuses and in seven of the 50 nonaborted fetuses. Antibodies to more than one agent were detected in eleven of the 100 aborted and in one of the 50 nonaborted fetuses. Reasons for this occurrence and application of the test in determination of causes of abortion are discussed. PMID:226243

  19. MTBDRplus and MTBDRsl Assays: Absence of Wild-Type Probe Hybridization and Implications for Detection of Drug-Resistant Tuberculosis

    PubMed Central

    Georghiou, Sophia B.; Catanzaro, Donald; Rodrigues, Camilla; Crudu, Valeriu; Victor, Thomas C.; Garfein, Richard S.; Catanzaro, Antonino; Rodwell, Timothy C.

    2016-01-01

    Accurate identification of drug-resistant Mycobacterium tuberculosis is imperative for effective treatment and subsequent reduction in disease transmission. Line probe assays rapidly detect mutations associated with resistance and wild-type sequences associated with susceptibility. Examination of molecular-level performance is necessary for improved assay result interpretation and for continued diagnostic development. Using data collected from a large, multisite diagnostic study, probe hybridization results from line probe assays, MTBDRplus and MTBDRsl, were compared to those of sequencing, and the diagnostic performance of each individual mutation and wild-type probe was assessed. Line probe assay results classified as resistant due to the absence of wild-type probe hybridization were compared to those of sequencing to determine if novel mutations were inhibiting wild-type probe hybridization. The contribution of absent wild-type probe hybridization to the detection of drug resistance was assessed via comparison to a phenotypic reference standard. In our study, mutation probes demonstrated significantly higher specificities than wild-type probes and wild-type probes demonstrated marginally higher sensitivities than mutation probes, an ideal combination for detecting the presence of resistance conferring mutations while yielding the fewest number of false-positive results. The absence of wild-type probe hybridization without mutation probe hybridization was determined to be primarily the result of failure of mutation probe hybridization and not the result of novel or rare mutations. Compared to phenotypic culture-based drug susceptibility testing, the absence of wild-type probe hybridization without mutation probe hybridization significantly contributed to the detection of phenotypic rifampin and fluoroquinolone resistance with negligible increases in false-positive results. PMID:26763971

  20. Delay differential equations via the matrix Lambert W function and bifurcation analysis: application to machine tool chatter.

    PubMed

    Yi, Sun; Nelson, Patrick W; Ulsoy, A Galip

    2007-04-01

    In a turning process modeled using delay differential equations (DDEs), we investigate the stability of the regenerative machine tool chatter problem. An approach using the matrix Lambert W function for the analytical solution to systems of delay differential equations is applied to this problem and compared with the result obtained using a bifurcation analysis. The Lambert W function, known to be useful for solving scalar first-order DDEs, has recently been extended to a matrix Lambert W function approach to solve systems of DDEs. The essential advantages of the matrix Lambert W approach are not only the similarity to the concept of the state transition matrix in lin ear ordinary differential equations, enabling its use for general classes of linear delay differential equations, but also the observation that we need only the principal branch among an infinite number of roots to determine the stability of a system of DDEs. The bifurcation method combined with Sturm sequences provides an algorithm for determining the stability of DDEs without restrictive geometric analysis. With this approach, one can obtain the critical values of delay, which determine the stability of a system and hence the preferred operating spindle speed without chatter. We apply both the matrix Lambert W function and the bifurcation analysis approach to the problem of chatter stability in turning, and compare the results obtained to existing methods. The two new approaches show excellent accuracy and certain other advantages, when compared to traditional graphical, computational and approximate methods.

  1. Hot fire test results of subscale tubular combustion chambers

    NASA Technical Reports Server (NTRS)

    Kazaroff, John M.; Jankovsky, Robert S.; Pavli, Albert J.

    1992-01-01

    Advanced, subscale, tubular combustion chambers were built and test fired with hydrogen-oxygen propellants to assess the increase in fatigue life that can be obtained with this type of construction. Two chambers were tested: one ran for 637 cycles without failing, compared to a predicted life of 200 cycles for a comparable smooth-wall milled-channel liner configuration. The other chamber failed at 256 cycles, compared to a predicted life of 118 cycles for a comparable smooth-wall milled-channel liner configuration. Posttest metallographic analysis determined that the strain-relieving design (structural compliance) of the tubular configuration was the cause of this increase in life.

  2. Non-Contact Determination of Antisymmetric Plate Wave Velocity in Ceramic Matrix Composites

    NASA Technical Reports Server (NTRS)

    Kautz, Harold E.

    1996-01-01

    A 13 mJ NdYAG 1064 nm, 4 ns, laser pulse was employed to produce ultrasonic plate waves in 20 percent porous SiC/SiC composite tensile specimens of three different architectures. An air coupled 0.5 MHz transducer was used to detect and collect the waveforms which contained first antisymmetric plate wave pulses for determining the shear wave velocity (VS). These results were compared to VS values determined on the same specimens with 0.5 MHz ultrasonic transducers with contact coupling. Averages of four noncontact determinations on each of 18 specimens were compared to averages of four contact values. The noncontact VS's fall in the same range as the contact. The standard deviations for the noncontact VS's averaged 2.8 percent. The standard deviations for the contact measurements averaged 2.3 percent, indicating similar reproducibility. Repeated laser pulsing at the same location always lead to deterioration of the ulu-"nic signal. The signal would recover in about 24 hr in air however, indicating that no permanent damage was produced.

  3. Application of multiattribute decision-making methods for the determination of relative significance factor of impact categories.

    PubMed

    Noh, Jaesung; Lee, Kun Mo

    2003-05-01

    A relative significance factor (f(i)) of an impact category is the external weight of the impact category. The objective of this study is to propose a systematic and easy-to-use method for the determination of f(i). Multiattribute decision-making (MADM) methods including the analytical hierarchy process (AHP), the rank-order centroid method, and the fuzzy method were evaluated for this purpose. The results and practical aspects of using the three methods are compared. Each method shows the same trend, with minor differences in the value of f(i). Thus, all three methods can be applied to the determination of f(i). The rank order centroid method reduces the number of pairwise comparisons by placing the alternatives in order, although it has inherent weakness over the fuzzy method in expressing the degree of vagueness associated with assigning weights to criteria and alternatives. The rank order centroid method is considered a practical method for the determination of f(i) because it is easier and simpler to use compared to the AHP and the fuzzy method.

  4. Comparative evaluation of an ISO 3632 method and an HPLC-DAD method for safranal quantity determination in saffron.

    PubMed

    García-Rodríguez, M Valle; López-Córcoles, Horacio; Alonso, Gonzalo L; Pappas, Christos S; Polissiou, Moschos G; Tarantilis, Petros A

    2017-04-15

    The aim of this work was a comparison of the ISO 3632 (2011) method and an HPLC-DAD method for safranal quantity determination in saffron. Samples from different origins were analysed by UV-vis according to ISO 3632 (2011) and by HPLC-DAD. Both methods were compared, and there was no correlation between the safranal content obtained by UV-vis and HPLC-DAD. An over-estimation in the UV-vis experiment was observed, which was related to the cis-crocetin esters content, as well as other compounds. The results demonstrated that there was no relationship between ISO quality categories and safranal content using HPLC-DAD. Therefore, HPLC-DAD might be preferable to UV-vis for determining the safranal content and the classification of saffron for commercial purposes. In addition, HPLC-DAD was adequate for determining the three foremost parameters that define the quality of saffron (crocetin esters, picrocrocin and safranal); therefore, this approach could be included in the ISO 3632 method (2011). Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Microcomputer Assisted Interpretative Reporting of Sequential Creatine Kinase (CK) and Lactate Dehydrogenase (LDH) Isoenzyme Determination

    PubMed Central

    Talamo, Thomas S.; Losos, Frank J.; Mercer, Donald W.

    1984-01-01

    We have developed a microcomputer based system for interpretative reporting of creatine kinase (CK) and lactate dehydrogenase (LDH) isoenzyme studies. Patient demographic data and test results (total CK, CK-MB, LD-1, and LD-2) are entered manually through the keyboard. The test results are compared with normal range values and an interpretative report is generated. This report consists of all pertinent demographic information with a graphic display of up to 12 previous CK and LDH isoenzyme determinations. Diagnostic interpretative statements are printed beneath the graphic display following analysis of previously entered test results. The combination of graphic data display and interpretations based on analysis of up to 12 previous specimens provides useful and accurate information to the cardiologist.

  6. The effects of corona on current surges induced on conducting lines by EMP: A comparison of experiment data with results of analytic corona models

    NASA Astrophysics Data System (ADS)

    Blanchard, J. P.; Tesche, F. M.; McConnell, B. W.

    1987-09-01

    An experiment to determine the interaction of an intense electromagnetic pulse (EMP), such as that produced by a nuclear detonation above the Earth's atmosphere, was performed in March, 1986 at Kirtland Air Force Base near Albuquerque, New Mexico. The results of that experiment have been published without analysis. Following an introduction of the corona phenomenon, the reason for interest in it, and a review of the experiment, this paper discusses five different analytic corona models that may model corona formation on a conducting line subjected to EMP. The results predicted by these models are compared with measured data acquired during the experiment to determine the strengths and weaknesses of each model.

  7. Sediments from stormwater drainage system as sorbents of organic and inorganic pollutants

    NASA Astrophysics Data System (ADS)

    Sałata, Aleksandra; Dąbek, Lidia

    2017-11-01

    The study presents the results of tests aimed at determining variations in concentrations of polycyclic aromatic hydrocarbons (naphthalene, acenaphthylene, acenaphthene, fluorene, phenanthrene, anthracene, fluoranthene, pyrene, benzo[a]anthracene, chrysene, benzo[b]fluoranthene, benzo[k]fluoranthene, benzo[a]pyrene, dibenzo[a, h]anthracene, benzo[g, h, i]perylene and indeno[1, 2, 3-c, d]pyrene) and heavy metals (copper, cadmium, chromium, nickel, lead and zinc) in the sediments from the stormwater sewer system. Results of this study were then compared to Polish regulations and established ecological screening values to determine their potential risk to environment. The results suggest that stormwater sediments are moderately contaminated with PAHs and heavy metals according to domestic regulations and highly contaminated according to ecological benchmarks.

  8. ATS simultaneous and turnaround ranging experiments

    NASA Technical Reports Server (NTRS)

    Watson, J. S.; Putney, B. H.

    1971-01-01

    This report explains the data reduction and spacecraft position determination used in conjunction with two ATS experiments - Trilateration and Turnaround Ranging - and describes in detail a multilateration program that is used for part of the data reduction process. The process described is for the determination of the inertial position of the satellite, and for formating input for related programs. In the trilateration procedure, a geometric determination of satellite position is made from near simultaneous range measurements made by three different tracking stations. Turnaround ranging involves two stations; one, the master station, transmits the signal to the satellite and the satellite retransmits the signal to the slave station which turns the signal around to the satellite which in turn retransmits the signal to the master station. The results of the satellite position computations using the multilateration program are compared to results of other position determination programs used at Goddard. All programs give nearly the same results which indicates that because of its simplicity and computational speed the trilateration technique is useful in obtaining spacecraft positions for near synchronous satellites.

  9. A new method to determine magnetic properties of the unsaturated-magnetized rotor of a novel gyro

    NASA Astrophysics Data System (ADS)

    Li, Hai; Liu, Xiaowei; Dong, Changchun; Zhang, Haifeng

    2016-06-01

    A new method is proposed to determine magnetic properties of the unsaturated-magnetized, small and irregular shaped rotor of a novel gyro. The method is based on finite-element analysis and the measurements of the magnetic flux density distribution, determining magnetic parameters by comparing the magnetic flux intensity distribution differences between the modeling results under different parameters and the measured ones. Experiment on a N30 Grade NdFeB magnet shows that its residual magnetic flux density is 1.10±0.01 T, and coercive field strength is 801±3 kA/m, which are consistent with the given parameters of the material. The method was applied to determine the magnetic properties of the rotor of the gyro, and the magnetic properties acquired were used to predict the open-loop gyro precession frequency. The predicted precession frequency should be larger than 12.9 Hz, which is close to the experimental result 13.5 Hz. The result proves that the method is accurate in estimating the magnetic properties of the rotor of the gyro.

  10. Direct and precise determination of environmental radionuclides in solid materials using a modified Marinelli beaker and a HPGe detector.

    PubMed

    Seo, B K; Lee, K Y; Yoon, Y Y; Lee, D W

    2001-06-01

    A simple but precise detection method was studied for the determination of natural radionuclides using a conventional HPGe detector. A new aluminium beaker instead of a plastic Marinelli beaker was constructed and examined to reach radioactive equilibrium conditions between radon and its daughter elements without the escape of gaseous radon. Using this beaker fifteen natural radionuclides from three natural decay series could be determined by direct gamma-ray measurement and sixteen radionuclides could be determined indirectly after radioactive equilibrium had been reached. Analytical results from ground water were compared with those from conventional alpha spectroscopy and the results agreed well within 12% difference. Nitrogen gas purge was used to replace the surrounding air of the detector to obtain a stable background and reducing the interference of radon daughter nuclides in the atmosphere. The use of nitrogen purging and the aluminium Marinelli beaker results in an approximately tenfold increase of sensitivity and a decrease of the detection limit of 226Ra to about 0.74 Bq kg(-1) in soil samples.

  11. Placement into First College Mathematics Course: A Comparison of the Results of the Michigan State University Proctored Mathematics Placement Examination and the Unproctored Mathematics Placement Examination

    ERIC Educational Resources Information Center

    Drake, Samuel

    2010-01-01

    The primary purpose of this study was to compare the results of the Michigan State University (MSU) unproctored examination to the results of the proctored examination. Both examinations are used to determine whether first time freshmen at MSU are ready for a standard mathematics course or if a remedial course is necessary. In addition to…

  12. In-flight investigation of a rotating cylinder-based structural excitation system for flutter testing

    NASA Technical Reports Server (NTRS)

    Vernon, Lura

    1993-01-01

    A research excitation system was test flown at the NASA Dryden Flight Research Facility on the two-seat F-16XL aircraft. The excitation system is a wingtip-mounted vane with a rotating slotted cylinder at the trailing edge. As the cylinder rotates during flight, the flow is alternately deflected upward and downward through the slot, resulting in a periodic lift force at twice the cylinder's rotational frequency. Flight testing was conducted to determine the excitation system's effectiveness in the subsonic and transonic flight regimes. Primary research objectives were to determine the system's ability to develop adequate force levels to excite the aircraft's structure and to determine the frequency range over which the system could excite structural modes of the aircraft. The results from the exciter were compared with results from atmospheric turbulence excitation at the same flight conditions. The results from the forced excitation were of higher quality and had less variation than the results from atmospheric turbulence. The forced excitation data also invariably yielded higher structural damping values than those from the atmospheric turbulence data.

  13. Pediatric Emergency Care Applied Research Network head injuryprediction rules: on the basis of cost and effectiveness

    PubMed

    Gökharman, Fatma Dilek; Aydın, Sonay; Fatihoğlu, Erdem; Koşar, Pınar Nercis

    2017-12-19

    Background/aim: Head injuries are commonly seen in the pediatric population. Noncontrast enhanced cranial CT is the method of choice to detect possible traumatic brain injury (TBI). Concerns about ionizing radiation exposure make the evaluation more challenging. The aim of this study was to evaluate the effectiveness of the Pediatric Emergency Care Applied Research Network (PECARN) rules in predicting clinically important TBI and to determine the amount of medical resource waste and unnecessary radiation exposure.Materials and methods: This retrospective study included 1041 pediatric patients presented to the emergency department. The patients were divided into subgroups of "appropriate for cranial CT", "not appropriate for cranial CT" and "cranial CT/observation of patient; both are appropriate". To determine the effectiveness of the PECARN rules, data were analyzed according to the presence of pathological findings Results: "Appropriate for cranial CT" results can predict pathology presence 118,056-fold compared to the "not appropriate for cranial CT" results. With "cranial CT/observation of patient; both are appropriate" results, pathology presence was predicted 11,457-fold compared to "not appropriate for cranial CT" results.Conclusion: PECARN rules can predict pathology presence successfully in pediatric TBI. Using PECARN can decrease resource waste and exposure to ionizing radiation.

  14. Comparing methods of ploidy estimation in potato.

    USDA-ARS?s Scientific Manuscript database

    Ploidy manipulation and the resulting need for rapid ploidy screening is an important part of a potato research and breeding program. Determining ploidy by counting chromosomes or measuring DNA in individual cells is definitive, but takes time, technical skills and equipment. We tested three predi...

  15. Comparison of Pre and Post Road Test Ultrasonic Inspection Results on 134 Passenger Tires

    DOT National Transportation Integrated Search

    1979-11-01

    A study was conducted to compare ultrasonic inspection data from 134 tires prior and subsequent to road tests in order to determine whether excessive tread wear could be related to characteristics detected by the ultrasonic inspection. Analysis of da...

  16. Determining Differences in Efficacy of Two Disinfectants Using t-Tests.

    ERIC Educational Resources Information Center

    Brehm, Michael A.; And Others

    1996-01-01

    Presents an experiment to compare the effectiveness of 95% ethanol to 20% bleach as disinfectants using t-tests for the statistical analysis of the data. Reports that bleach is a better disinfectant. Discusses the statistical and practical significance of the results. (JRH)

  17. Disaggregating tropical disease prevalence by climatic and vegetative zones within tropical West Africa

    USDA-ARS?s Scientific Manuscript database

    Tropical infectious disease prevalence is dependent on many socio-cultural determinants. However, rainfall and temperature frequently underlie overall prevalence, particularly for vector-borne diseases. As a result these diseases have increased prevalence in tropical as compared to temperate regions...

  18. Two transducer formula for more precise determination of ultrasonic phase velocity from standing wave measurements

    NASA Technical Reports Server (NTRS)

    Ringermacher, H. I.; Moerner, W. E.; Miller, J. G.

    1974-01-01

    A two transducer correction formula valid for both solid and liquid specimens is presented. Using computer simulations of velocity measurements, the accuracy and range of validity of the results are discussed and are compared with previous approximations.

  19. Analysis of Trihalomethanes in Soft Drinks: An Instrumental Analysis Experiment.

    ERIC Educational Resources Information Center

    Graham, Richard C.; Robertson, John K.

    1988-01-01

    Describes an experimental procedure for determining trihalomethanes (THMs) in liquids by gas chromatography. Provides recommendations for reactants and supplies to obtain acceptable results. Discusses the analysis of water from various sources: pools, lakes, and drinking water; compares these to three cola drinks. (ML)

  20. Sex determination in skeletal remains from the medieval Eastern Adriatic coast – discriminant function analysis of humeri

    PubMed Central

    Bašić, Željana; Anterić, Ivana; Vilović, Katarina; Petaros, Anja; Bosnar, Alan; Madžar, Tomislav; Polašek, Ozren; Anđelinović, Šimun

    2013-01-01

    Aim To investigate the usefulness of humerus measurement for sex determination in a sample of medieval skeletons from the Eastern Adriatic Coast. Additional aim was to compare the results with contemporary female population. Methods Five humerus measurements (maximum length, epicondylar width, maximum vertical diameter of the head, maximum and minimum diameter of the humerus at midshaft) for 80 male and 35 female medieval and 19 female contemporary humeri were recorded. Only sufficiently preserved skeletons and those with no obvious pathological or traumatic changes that could affect the measurements were included. For ten samples, analysis of DNA was performed in order to determine sex using amelogenin. Results The initial comparison of men and women indicated significant differences in all five measures (P < 0.001). Discriminant function for sex determination indicated that as much as 85% of cases could be properly categorized, with better results in men (86%) than women (80%). Furthermore, the comparison of the medieval and contemporary women did not show significant difference in any of the measured features. Sex results obtained by anthropological and DNA analysis matched in all 10 cases. Conclusion The results indicate that humerus measurement in Croatian medieval population may be sufficient to determine the sex of the skeleton. Furthermore, it seems that secular changes have not substantially affected contemporary population, suggesting that the results of this study are transferable to contemporary population as well. PMID:23771758

  1. [A PhD completed 3. Soft tissue development around an implant in the aesthetic zone].

    PubMed

    Patil, R C

    2016-01-01

    A randomised clinical trial was carried out in order to determine whether changes in the abutment design result in improved quality of the peri-implant mucosal tissue according to the parameters attachment strength, sotft tissue stability and developmemt, and maintenance of bone levels. Twenty-nine patients were included. They received 2, non-adjacent endosseous implants replacing missing teeth in the aesthetic zone. Subsequently, conventional (control) and experimental abutments (with an additional macro groove of about 0.5 mm in depth ) were placed. After 6 weeks and 1 year the effect of the 2 different abutment designs were measured according to the specified parameters. In addition, patients' and dentists' satisfaction concerning the muco-gingival results were compared. It was concluded that the 2 abutments produced no significantly different effect on muco-gingival aesthetics. On the basis of additional comparative research between Caucasian and Indian individuals it was concluded that the gingival biotype could best be determined quantitatively.

  2. Timing of testing and treatment for asymptomatic diseases

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kırkızlar, Eser; Faissol, Daniel M.; Griffin, Paul M.

    2010-07-01

    Many papers in the medical literature analyze the cost-effectiveness of screening for diseases by comparing a limited number of a priori testing policies under estimated problem parameters. However, this may be insufficient to determine the best timing of the tests or incorporate changes over time. In this paper, we develop and solve a Markov Decision Process (MDP) model for a simple class of asymptomatic diseases in order to provide the building blocks for analysis of a more general class of diseases. We provide a computationally efficient method for determining a cost-effective dynamic intervention strategy that takes into account (i) themore » results of the previous test for each individual and (ii) the change in the individual’s behavior based on awareness of the disease. We demonstrate the usefulness of the approach by applying the results to screening decisions for Hepatitis C (HCV) using medical data, and compare our findings to current HCV screening recommendations.« less

  3. Removal Efficiency of COD, Total P and Total N Components from Municipal Wastewater using Hollow-fibre MBR.

    PubMed

    Petrinić, Irena; Curlin, Mirjana; Korenak, Jasmina; Simonič, Marjana

    2011-06-01

    The membrane bioreactor (MBR) integrates well within the conventionally activated sludge system regarding advanced membrane separation for wastewater treatment. Over the last decade, a number of MBR systems have been constructed worldwide and this system is now accepted as a technology of choice for wastewater treatment especially for municipal wastewater. The aim of this work was to investigate and compare submerged MBR with conventionally-activated sludge system for the treatment of municipal wastewater in Maribor, Slovenia. It can be concluded from the results, that the efficiencies being determined by the parameters were satisfied, such as, chemical oxygen demand, total phosphorous, and total nitrogen, which were 97%, 75%, and 90%, respectively. The efficiencies of ultrafiltration membrane for the same parameters were also determined, and compared with biological treatment. The results of this analysis show an additional effect regarding an improvement in the quality of the permeate but primary treatment is also very important. For successfully application of MBR system smaller grid for primary treatment is needed.

  4. Meta-analysis of laparoscopic versus open repair of perforated peptic ulcer.

    PubMed

    Antoniou, Stavros A; Antoniou, George A; Koch, Oliver O; Pointner, Rudolph; Granderath, Frank A

    2013-01-01

    Laparoscopic treatment of perforated peptic ulcer (PPU) has been introduced as an alternative procedure to open surgery. It has been postulated that the minimally invasive approach involves less operative stress and results in decreased morbidity and mortality. We conducted a meta-analysis of randomized trials to test this hypothesis. Medline, EMBASE, and the Cochrane Central Register of Randomized Trials databases were searched, with no date or language restrictions. Our literature search identified 4 randomized trials, with a cumulative number of 289 patients, that compared the laparoscopic approach with open sutured repair of perforated ulcer. Analysis of outcomes did not favor either approach in terms of morbidity, mortality, and reoperation rate, although odds ratios seemed to consistently support the laparoscopic approach. Results did not determine the comparative efficiency and safety of laparoscopic or open approach for PPU. In view of an increased interest in the laparoscopic approach, further randomized trials are considered essential to determine the relative effectiveness of laparoscopic and open repair of PPU.

  5. 76 FR 64904 - Building Energy Standards Program: Final Determination Regarding Energy Efficiency Improvements...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-19

    ... Determination 3. Public Comments Regarding the Preliminary Determination II. Summary of the Comparative Analysis... the Department to finalize this determination. II. Summary of the Comparative Analysis DOE carried out...

  6. Design and development aspects of flexure mechanism for high precision application

    NASA Astrophysics Data System (ADS)

    Sollapur, Shrishail B.; Patil, M. S.; Deshmukh, S. P.

    2018-04-01

    Planer XY Flexurel Mechanisms has various applications in precision motion mechanisms. A flexural mechanism generates relative motion between fixed support and motion stage using flexibility of material. This mechanism offers zero backlash, frictionless motion and high order repeatability. It is relatively compact in design as compared to rigid link mechanism. The merits of using flexure is complete mechanism can be from single monolith. Modelling of flexural mechanism to provide accurate scanning of comparatively larger range at a higher speed. Static Analysis of mechanism is carried out on FEA tool to determine static deflection of motion stage. Further Mechanism is actuated with the help of weight pan and weights. The resultant displacement is measured on Dial Gauge Indicator. Experimental set-up consists of Flexural mechanism, Dial Gauge, Weight Pan and Weights, Pulley, String, Small metal strip, Optical Bread Board etc. Further experimental Results and Analytical Results are compared and minimum deviation is found.

  7. Do clinical safety charts improve paramedic key performance indicator results? (A clinical improvement programme evaluation).

    PubMed

    Ebbs, Phillip; Middleton, Paul M; Bonner, Ann; Loudfoot, Allan; Elliott, Peter

    2012-07-01

    Is the Clinical Safety Chart clinical improvement programme (CIP) effective at improving paramedic key performance indicator (KPI) results within the Ambulance Service of New South Wales? The CIP intervention area was compared with the non-intervention area in order to determine whether there was a statistically significant improvement in KPI results. The CIP was associated with a statistically significant improvement in paramedic KPI results within the intervention area. The strategies used within this CIP are recommended for further consideration.

  8. Cost-utility analysis of a multidisciplinary strategy to manage osteoarthritis of the knee: economic evaluation of a cluster randomized controlled trial study.

    PubMed

    Marra, Carlo A; Grubisic, Maja; Cibere, Jolanda; Grindrod, Kelly A; Woolcott, John C; Gastonguay, Louise; Esdaile, John M

    2014-06-01

    To determine if a pharmacist-initiated multidisciplinary strategy provides value for money compared to usual care in participants with previously undiagnosed knee osteoarthritis. Pharmacies were randomly allocated to provide either 1) usual care and a pamphlet or 2) intervention care, which consisted of education, pain medication management by a pharmacist, physiotherapy-guided exercise, and communication with the primary care physician. Costs and quality-adjusted life-years (QALYs) were determined for patients assigned to each treatment and incremental cost-effectiveness ratios (ICERs) were determined. From the Ministry of Health perspective, the average patient in the intervention group generated slightly higher costs compared with usual care. Similar findings were obtained when using the societal perspective. The intervention resulted in ICERs of $232 (95% confidence interval [95% CI] -1,530, 2,154) per QALY gained from the Ministry of Health perspective and $14,395 (95% CI 7,826, 23,132) per QALY gained from the societal perspective, compared with usual care. A pharmacist-initiated, multidisciplinary program was good value for money from both the societal and Ministry of Health perspectives. Copyright © 2014 by the American College of Rheumatology.

  9. Improved heuristics for early melanoma detection using multimode hyperspectral dermoscopy (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Vasefi, Fartash; MacKinnon, Nicholas B.; Booth, Nicholas; Farkas, Daniel L.

    2017-02-01

    Purpose: To determine the performance of a multimode dermoscopy system (SkinSpect) designed to quantify and 3-D map in vivo melanin and hemoglobin concentrations in skin and its melanoma scoring system, and compare the results accuracy with SIAscopy, and histopathology. Methods: A multimode imaging dermoscope is presented that combines polarization, fluorescence and hyperspectral imaging to accurately map the distribution of skin melanin, collagen and hemoglobin in pigmented lesions. We combine two depth-sensitive techniques: polarization, and hyperspectral imaging, to determine the spatial distribution of melanin and hemoglobin oxygenation in a skin lesion. By quantifying melanin absorption in pigmented areas, we can also more accurately estimate fluorescence emission distribution mainly from skin collagen. Results and discussion: We compared in vivo features of melanocytic lesions (N = 10) extracted by non-invasive SkinSpect and SIMSYS-MoleMate SIAscope, and correlate them to pathology report. Melanin distribution at different depths as well as hemodynamics including abnormal vascularity we detected will be discussed. We will adapt SkinSpect scoring with ABCDE (asymmetry , border, color, diameter, evolution) and seven point dermatologic checklist including: (1) atypical pigment network, (2) blue-whitish veil, (3) atypical vascular pattern, (4) irregular streaks, (5) irregular pigmentation, (6) irregular dots and globules, (7) regression structures estimated by dermatologist. Conclusion: Distinctive, diagnostic features seen by SkinSpect in melanoma vs. normal pigmented lesions will be compared by SIAscopy and results from histopathology.

  10. Laparoscopy Improves Short-term Outcomes After Surgery for Diverticular Disease

    PubMed Central

    RUSS, ANDREW J.; OBMA, KARI L.; RAJAMANICKAM, VICTORIA; WAN, YIN; HEISE, CHARLES P.; FOLEY, EUGENE F.; HARMS, BRUCE; KENNEDY, GREGORY D.

    2012-01-01

    BACKGROUND & AIMS Observational studies and small randomized controlled trials have shown that the use of laparoscopy in colon resection for diverticular disease is feasible and results in fewer complications. We analyzed data from a large, prospectively maintained, multicenter database (National Surgical Quality Initiative Program) to determine whether the use of laparoscopy in the elective treatment of diverticular disease decreases rates of complications compared with open surgery, independent of preoperative comorbid factors. METHODS The analysis included data from 6970 patients who underwent elective surgeries for diverticular disease from 2005 to 2008. Patients with diverticular disease were identified by International Classification of Diseases, 9th revision codes and then categorized into open or laparoscopic groups based on Current Procedural Terminology codes. Preoperative, intraoperative, and postoperative data were analyzed to determine factors associated with increased risk for postoperative complications. RESULTS Data were analyzed from 3468 patients who underwent open surgery and 3502 patients who underwent laparoscopic procedures. After correcting for probability of morbidity, American Society of Anesthesiology class, and ostomy creation, overall complications (including superficial surgical site infections, deep incisional surgical site infections, sepsis, and septic shock) occurred with significantly lower incidence among patients who underwent laparoscopic procedures compared with those who received open operations. CONCLUSIONS The use of laparoscopy for treating diverticular disease, in the absence of absolute contraindications, results in fewer postoperative complications compared with open surgery. PMID:20193685

  11. A comparative study of the antacid effect of raw spinach juice and spinach extract in an artificial stomach model.

    PubMed

    Panda, Vandana Sanjeev; Shinde, Priyanka Mangesh

    2016-12-01

    BackgroundSpinacia oleracea known as spinach is a green-leafy vegetable consumed by people across the globe. It is reported to possess potent medicinal properties by virtue of its numerous antioxidant phytoconstituents, together termed as the natural antioxidant mixture (NAO). The present study compares the antacid effect of raw spinach juice with an antioxidant-rich methanolic extract of spinach (NAOE) in an artificial stomach model. MethodsThe pH of NAOE at various concentrations (50, 100 and 200 mg/mL) and its neutralizing effect on artificial gastric acid was determined and compared with that of raw spinach juice, water, the active control sodium bicarbonate (SB) and a marketed antacid preparation ENO. A modified model of Vatier's artificial stomach was used to determine the duration of consistent neutralization of artificial gastric acid for the test compounds. The neutralizing capacity of test compounds was determined in vitro using the classical titration method of Fordtran. Results NAOE (50, 100 and 200 mg/mL), spinach juice, SB and ENO showed significantly better acid-neutralizing effect, consistent duration of neutralization and higher antacid capacity when compared with water. Highest antacid activity was demonstrated by ENO and SB followed by spinach juice and NAOE200. Spinach juice exhibited an effect comparable to NAOE (200 mg/mL). ConclusionsThus, it may be concluded that spinach displays significant antacid activity be it in the raw juice form or as an extract in methanol.

  12. Human uterine cervical epithelial cells grown on permeable support--a new model for the study of differentiation.

    PubMed

    Gorodeski, G I; Romero, M F; Hopfer, U; Rorke, E; Utian, W H; Eckert, R L

    1994-04-01

    The purpose of the present study was to establish culture conditions for human uterine cervical epithelial cells on permeable support and to determine how it affects cervical cell differentiation. Human ectocervical epithelial cells (hECE), HPV-16 immortalized hECE cells (ECE16-1) and Caski cells were grown on collagen-coated filters. Culture conditions, density of cells in culture and expression of epithelial and cervical-cell phenotypic markers were determined and compared in cells grown on filter and on solid support. Compared with the latter, cultures on filter had a higher cell density, hECE cells stratified to 5-12 cell layers compared to 1-3 on solid support, and cells of all three types expressed intercellular tight junctions. The cytokeratin profiles revealed differences between the three cell types as well as differences within the same cell species when grown on filter, compared to solid support. Of particular importance was the finding of a higher expression of K-13 in hECE grown on filter compared to solid support; K-13 is a marker of ectocervical cell differentiation. The cytokeratin profiles of the cultured hECE, ECE16-1 and Caski cells resembled those of ectocervical, squamous metaplastic and endocervical epithelia, respectively. hECE and ECE16-1 expressed involucrin protein, the level of which in both was higher in cells grown on filter compared to solid support. Polarization of the cultures was determined by morphology (stratification of hECE cells, expression of pseudomicrovilli in the apical cell membrane), selective apical vs. basolateral secretion of [35S]methionine- and [35S]cysteine-, [3H]fucose- and [14C]glucosamine-labeled molecules, and positive short-circuit current (Isc) under voltage-clamp conditions. Confluency of the cultures was determined by measuring transepithelial unidirectional fluxes of inert molecules with different molecular weights (MWs) through the paracellular pathway, and by measuring transepithelial conductance. The results indicated transepithelial permeability of 7-22.10(-6) cm.sec-1, which was 5-100 fold smaller compared to blank inserts, with a cut-off MW of 40-70 kDa for hECE and Caski cells. Transepithelial conductance ranged 18.5 to 51.5 mS.cm-2, indicating a leaky but confluent epithelia. Collectively the results indicate the epithelial nature of the cells and their improved differentiation when grown on filter support; hECE is a model for ectocervical epithelium while ECE16-1 and Caski express phenotypic characteristics of squamous metaplastic cervical epithelium and endocervical epithelium respectively.

  13. Calculation of craters resulting from impact rupture of rock mass using pulse hydrodynamic problem formulation

    NASA Astrophysics Data System (ADS)

    Gorodilov, LV; Rasputina, TB

    2018-03-01

    A liquid–solid hydrodynamic model is used to determine shapes and sizes of craters generated by impact rupture of rocks. Near the impact location, rock is modeled by an ideal incompressible liquid, in the distance—by an absolute solid. The calculated data are compared with the experimental results obtained under impact treatment of marble by a wedge-shaped tool.

  14. Finnish and UK English Pre-Teen Children's Text Message Language and Its Relationship with Their Literacy Skills

    ERIC Educational Resources Information Center

    Plester, B.; Lerkkanen, M.-K.; Linjama, L. J.; Rasku-Puttonen, H.; Littleton, K.

    2011-01-01

    The aim of the study was to demonstrate the style of text language used by Finnish pre-teen texters (n = 65) and determine how their text language related to their traditional literacy skills, and compare descriptively these results with earlier results from work with young English texters. Three kinds of text messages (natural texts, elicited…

  15. Rare earths and other trace elements in Luna 16 soil.

    NASA Technical Reports Server (NTRS)

    Helmke, P. A.; Haskin, L. A.

    1972-01-01

    An analysis has been made of four small samples of material brought to earth by the Luna 16 mission, with the aim to determine rare earths and other trace elements in these samples. The analytical results are tabulated, and the rare earth abundances are compared with the average for chondrites. A comparison is also made with the results of similar analyses of Apollo samples.

  16. Violence Prevention in Georgia's Rural Public School Systems: A Comparison of Perceptions of School Superintendents 1995-2005

    ERIC Educational Resources Information Center

    Ballard, Chet; Brady, Lauren

    2007-01-01

    School superintendents in 60 public school systems in Georgia were surveyed to describe strategies being pursued to prevent school violence and promote a safe learning environment. Results from the present study were compared with results from a survey of superintendents conducted by one of the authors in 1995 to determine the extent of change in…

  17. Field test results--a new logging tool for formation density and lithology measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Borai, A.M.; Muhsin, M.A.

    1983-03-01

    The formation porosity can be determined from borehole density measurements if the density of the rock is known. Generally, this is determined from the lithology. The Litho-Density Tool, LDT, provides an improved measurement of the formation density and a new measurement of lithology. Field tests of LDT proved that the tool could be run alone in a wide range of formations to provide porosity values comparable to those obtained by running a density log combined with a neutron log.

  18. Toxicity to Daphnia pulex and QSAR predictions for polycyclic hydrocarbons representative of Great Lakes contaminants

    USGS Publications Warehouse

    Passino-Reader, D.R.; Hickey, J.P.; Ogilvie, L.M.

    1997-01-01

    The objectives of this study were (1) to determine the toxicity of several types of polycyclic hydrocarbons characteristic of Great Lakes samples to Daphnia pulex, a Great Lakes zooplankter, (2) to investigate the influence of different structural characteristics on toxicity, and (3) to determine the linear solvation energy relationship (LSER) parameters and model that describe these compounds. These results will be related to comparative toxicity of other Great Lakes environmental compounds and to their application in site specific risk assessment.

  19. Comparison of Sigma-Point and Extended Kalman Filters on a Realistic Orbit Determination Scenario

    NASA Technical Reports Server (NTRS)

    Gaebler, John; Hur-Diaz. Sun; Carpenter, Russell

    2010-01-01

    Sigma-point filters have received a lot of attention in recent years as a better alternative to extended Kalman filters for highly nonlinear problems. In this paper, we compare the performance of the additive divided difference sigma-point filter to the extended Kalman filter when applied to orbit determination of a realistic operational scenario based on the Interstellar Boundary Explorer mission. For the scenario studied, both filters provided equivalent results. The performance of each is discussed in detail.

  20. Comparison of multianalyte proficiency test results by sum of ranking differences, principal component analysis, and hierarchical cluster analysis.

    PubMed

    Škrbić, Biljana; Héberger, Károly; Durišić-Mladenović, Nataša

    2013-10-01

    Sum of ranking differences (SRD) was applied for comparing multianalyte results obtained by several analytical methods used in one or in different laboratories, i.e., for ranking the overall performances of the methods (or laboratories) in simultaneous determination of the same set of analytes. The data sets for testing of the SRD applicability contained the results reported during one of the proficiency tests (PTs) organized by EU Reference Laboratory for Polycyclic Aromatic Hydrocarbons (EU-RL-PAH). In this way, the SRD was also tested as a discriminant method alternative to existing average performance scores used to compare mutlianalyte PT results. SRD should be used along with the z scores--the most commonly used PT performance statistics. SRD was further developed to handle the same rankings (ties) among laboratories. Two benchmark concentration series were selected as reference: (a) the assigned PAH concentrations (determined precisely beforehand by the EU-RL-PAH) and (b) the averages of all individual PAH concentrations determined by each laboratory. Ranking relative to the assigned values and also to the average (or median) values pointed to the laboratories with the most extreme results, as well as revealed groups of laboratories with similar overall performances. SRD reveals differences between methods or laboratories even if classical test(s) cannot. The ranking was validated using comparison of ranks by random numbers (a randomization test) and using seven folds cross-validation, which highlighted the similarities among the (methods used in) laboratories. Principal component analysis and hierarchical cluster analysis justified the findings based on SRD ranking/grouping. If the PAH-concentrations are row-scaled, (i.e., z scores are analyzed as input for ranking) SRD can still be used for checking the normality of errors. Moreover, cross-validation of SRD on z scores groups the laboratories similarly. The SRD technique is general in nature, i.e., it can be applied to any experimental problem in which multianalyte results obtained either by several analytical procedures, analysts, instruments, or laboratories need to be compared.

Top