Sample records for determining detection limits

  1. 40 CFR Appendix B to Part 136 - Definition and Procedure for the Determination of the Method Detection Limit-Revision 1.11

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... calculated method detection limit. To insure that the estimate of the method detection limit is a good...) where: MDL = the method detection limit t(n-1,1- α=.99) = the students' t value appropriate for a 99... Determination of the Method Detection Limit-Revision 1.11 B Appendix B to Part 136 Protection of Environment...

  2. Procedures for determination of detection limits: application to high-performance liquid chromatography analysis of fat-soluble vitamins in human serum.

    PubMed

    Browne, Richard W; Whitcomb, Brian W

    2010-07-01

    Problems in the analysis of laboratory data commonly arise in epidemiologic studies in which biomarkers subject to lower detection thresholds are used. Various thresholds exist including limit of detection (LOD), limit of quantification (LOQ), and limit of blank (LOB). Choosing appropriate strategies for dealing with data affected by such limits relies on proper understanding of the nature of the detection limit and its determination. In this paper, we demonstrate experimental and statistical procedures generally used for estimating different detection limits according to standard procedures in the context of analysis of fat-soluble vitamins and micronutrients in human serum. Fat-soluble vitamins and micronutrients were analyzed by high-performance liquid chromatography with diode array detection. A simulated serum matrix blank was repeatedly analyzed for determination of LOB parametrically by using the observed blank distribution as well as nonparametrically by using ranks. The LOD was determined by combining information regarding the LOB with data from repeated analysis of standard reference materials (SRMs), diluted to low levels; from LOB to 2-3 times LOB. The LOQ was determined experimentally by plotting the observed relative standard deviation (RSD) of SRM replicates compared with the concentration, where the LOQ is the concentration at an RSD of 20%. Experimental approaches and example statistical procedures are given for determination of LOB, LOD, and LOQ. These quantities are reported for each measured analyte. For many analyses, there is considerable information available below the LOQ. Epidemiologic studies must understand the nature of these detection limits and how they have been estimated for appropriate treatment of affected data.

  3. USE OF METHOD DETECTION LIMITS IN ENVIRONMENTAL MEASUREMENTS

    EPA Science Inventory

    Environmental measurements often produce values below the method detection limit (MDL). Because low or zero values may be used in determining compliance with regulatory limits, in determining emission factors (typical concentrations emitted by a given type of source), or in model...

  4. Determining the 95% limit of detection for waterborne pathogen analyses from primary concentration to qPCR

    USDA-ARS?s Scientific Manuscript database

    The limit of detection (LOD) for qPCR-based analyses is not consistently defined or determined in studies on waterborne pathogens. Moreover, the LODs reported often reflect the qPCR assay rather than the entire sample process. Our objective was to develop a method to determine the 95% LOD (lowest co...

  5. 40 CFR Appendix C to Part 425 - Definition and Procedure for the Determination of the Method Detection Limit 1

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Determination of the Method Detection Limit 1 C Appendix C to Part 425 Protection of Environment ENVIRONMENTAL... CATEGORY Pt. 425, App. C Appendix C to Part 425—Definition and Procedure for the Determination of the... reagent water. (c) The concentration value that corresponds to the region of the standard curve where...

  6. On the Determination of Uncertainty and Limit of Detection in Label-Free Biosensors.

    PubMed

    Lavín, Álvaro; Vicente, Jesús de; Holgado, Miguel; Laguna, María F; Casquel, Rafael; Santamaría, Beatriz; Maigler, María Victoria; Hernández, Ana L; Ramírez, Yolanda

    2018-06-26

    A significant amount of noteworthy articles reviewing different label-free biosensors are being published in the last years. Most of the times, the comparison among the different biosensors is limited by the procedure used of calculating the limit of detection and the measurement uncertainty. This article clarifies and establishes a simple procedure to determine the calibration function and the uncertainty of the concentration measured at any point of the measuring interval of a generic label-free biosensor. The value of the limit of detection arises naturally from this model as the limit at which uncertainty tends when the concentration tends to zero. The need to provide additional information, such as the measurement interval and its linearity, among others, on the analytical systems and biosensor in addition to the detection limit is pointed out. Finally, the model is applied to curves that are typically obtained in immunoassays and a discussion is made on the application validity of the model and its limitations.

  7. Detection limits of antimicrobials in ewe milk by delvotest photometric measurements.

    PubMed

    Althaus, R L; Torres, A; Montero, A; Balasch, S; Molina, M P

    2003-02-01

    The Delvotest method detection limits per manufacturer's instructions at a fixed reading time of 3 h for 24 antimicrobial agents were determined in ewe milk by photometric measurement. For each drug, eight concentrations were tested on 20 ewe milk samples from individual ewes. Detection limits, determined by means of logistic regression models, were (microg/kg): 3, amoxycillin; 2, ampicillin; 18, cloxacillin; 1, penicillin "G"; 34, cefadroxil; 430, cephalosporin "C"; 40, cephalexin; 20, cefoperazone; 33, Ceftiofur; 18, cefuroxime; 6100, streptomycin; 1200, gentamycin; 2600, neomycin; 830, erythromycin; 100, tylosin; 180, doxycycline; 320, oxytetracycline; 590, tetracycline; 88, sulfadiazine; 44, sulfamethoxazole; 140, sulfametoxypyridazine; 48, sulfaquinoxaline; 12,000, chloramphenicol; and 290, trimethoprim. Whereas the beta-lactam antibiotics, sulphonamides, and tylosin were detected by Delvotest method at levels equal to those of maximum residue limits, its sensitivity needs to be enhanced to detect aminoglycosides, tetracyclines, streptomycin, chloramphenicol, and trimethoprim residues in ewe milk or to develop an integrated residue detection system for ewe milk with different sensitive microorganisms for each group of antiinfectious agents.

  8. CAPILLARY ELECTROPHORESIS/LASER-INDUCED FLUORESCENCE DETECTION OF FLUORESCEIN AS A GROUNDWATER MIGRATION TRACER

    EPA Science Inventory

    Capillary electrophoresis (CE) has been applied to the determination of the groundwater migration tracer dye fluorescein based on laser-induced fluorescence (LIF) detection and compared to determinations obtained with traditional spectrofluorimetry. Detection limits of injected d...

  9. Shot noise limited detection of OH using the technique of laser induced fluorescence

    NASA Technical Reports Server (NTRS)

    Bakalyar, D. M.; Davis, L. I., Jr.; Guo, C.; James, J. V.; Kakos, S.; Morris, P. T.; Wang, C. C.

    1984-01-01

    Nearly shot-noise limited detection of OH using the technique of laser-induced fluorescence is reported. A LIDAR configuration is used to excite fluorescence in a large volume and a narrow-bandwidth interference filter provides spectral discrimination. This arrangement alleviates the effect of ozone interference and facilitates image processing at relatively close distances. The detection limit is determined mainly by the shot-noise of the solar background. Ground-based measurements in Dearborn indicate a detection limit of better than 1 x 10 to the 6th power OH/cubic cm over a forty-minute acquisition period. Under favorable conditions, a comparable detection limit was also observed for airborne measurements.

  10. Shot noise limited detection of OH using the technique of laser-induced fluorescence

    NASA Technical Reports Server (NTRS)

    Bakalyar, D. M.; Davis, L. I., Jr.; Guo, C.; James, J. V.; Wang, C. C.; Kakos, S.; Morris, P. T.

    1984-01-01

    Nearly shot-noise limited detection of OH using the technique of laser-induced fluorescence is reported. A LIDAR configuration is used to excite fluoresence in a large volume and a narrow-bandwidth interference filter provides spectral discrimination. This arrangement alleviates the effect of ozone interference and facilitates image processing at relatively close distances. The detection limit is determined mainly by the short-noise of the solar background. Ground-based measurements in Dearborn indicate a detection limit of better than 1 x 10 to the 6th power OH/cubic cm over a forty-minute acquisition period. Under favorable conditions, a comparable detection limit was also observed for airborne measurements.

  11. The detection limits of antimicrobial agents in cow's milk by a simple Yoghurt Culture Test.

    PubMed

    Mohsenzadeh, M; Bahrainipour, A

    2008-09-15

    The aim of this study was to study performance of Yoghurt Culture Test (YCT) in the detection of antimicrobial residues in milk. For this purpose, the sensitivity of YCT for 15 antibiotics were determined. For each drug, 8 concentrations were tested. The detection limits of YCT at 2.5 h and 4 h incubation were determined (microg kg(-1)): 15 and 37.5, penicillin G; 4 and 5, ampicillin; 5 and 7.5, amoxycillin; 100 and 200, cephalexin; 80 and 100, cefazoline; 100 and 200, oxytetracycline; 500 and 100, chlortetracycline; 100 and 200, tetracycline; 150 and 200, doxycycline; 200 and 400, sulphadimidine; 500 and 1000, gentamycin; 1000 and 1500, spectinomycin; 400 and 500, erythromycin; 50 and 100, tylosin; 5000 and 10000, chloramphenicol. The YCT detection limits at 2.5 h incubation for ampicillin, cephalexin, tetracycline, oxytetracycline and tylosin are similar to those obtained as Maximum Residue Limit (MRL) according to Regulation 2377/90 EEC as set out by the European Union. In addition the detection limits of YCT for some antibiotics were lower than some of microbial inhibitor test.

  12. Determination of diphacinone in sea water, vertebrates, invertebrates, and bait pellet formulations following aerial broadcast on Mokapu Island, Molokai, Hawai'i

    USGS Publications Warehouse

    Gale, Robert W.; Tanner, Michael; Orazio, Carl E.

    2008-01-01

    This report presents the results of a study to determine diphacinone concentrations in samples of sea water and in fillet samples of fish and in limpets from the ocean adjacent to Mokapu Island and from reference samples from Molokai, Hawai'i; concentrations of the active ingredient (diphacinone) were also determined in samples of the Ramik Green bait pellets used for the broadcast study. After preparation, diphacinone concentrations were determined with high-performance liquid chromatography with photodiode array detection. No detectable concentrations of diphacinone were found in the fish, limpets, or sea-water samples from Mokapu Island or from the reference sites. The limit of detection for diphacinone in sea water was 18 nanograms per milliliter (parts per billion); the limit of detection in fish fillets was 10 nanograms per gram (parts per billion); and the limit of detection in limpets was 17 nanograms per gram. The average concentration of diphacinone in the Ramik Green bait pellets was 45 micrograms per gram (parts per million), which represents 90 percent of the nominal concentration stated for the product by the manufacturer.

  13. Determination of patulin in apple juice by high-performance liquid chromatography with diode-array detection.

    PubMed

    Bartolomé, B; Bengoechea, M L; Pérez-Ilzarbe, F J; Hernández, T; Estrella, I; Gómez-Cordovés, C

    1994-03-25

    A method is described for the detection of patulin in apple juice and the simultaneous determination of the phenolic composition. Spectral data obtained with diode-array detection showed that patulin can be easily distinguished from compounds eluting under the same conditions. The detection limit for patulin was 8.96 micrograms/l.

  14. Probabilistic pipe fracture evaluations for leak-rate-detection applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rahman, S.; Ghadiali, N.; Paul, D.

    1995-04-01

    Regulatory Guide 1.45, {open_quotes}Reactor Coolant Pressure Boundary Leakage Detection Systems,{close_quotes} was published by the U.S. Nuclear Regulatory Commission (NRC) in May 1973, and provides guidance on leak detection methods and system requirements for Light Water Reactors. Additionally, leak detection limits are specified in plant Technical Specifications and are different for Boiling Water Reactors (BWRs) and Pressurized Water Reactors (PWRs). These leak detection limits are also used in leak-before-break evaluations performed in accordance with Draft Standard Review Plan, Section 3.6.3, {open_quotes}Leak Before Break Evaluation Procedures{close_quotes} where a margin of 10 on the leak detection limit is used in determining the crackmore » size considered in subsequent fracture analyses. This study was requested by the NRC to: (1) evaluate the conditional failure probability for BWR and PWR piping for pipes that were leaking at the allowable leak detection limit, and (2) evaluate the margin of 10 to determine if it was unnecessarily large. A probabilistic approach was undertaken to conduct fracture evaluations of circumferentially cracked pipes for leak-rate-detection applications. Sixteen nuclear piping systems in BWR and PWR plants were analyzed to evaluate conditional failure probability and effects of crack-morphology variability on the current margins used in leak rate detection for leak-before-break.« less

  15. Determination of some aldehydes by using solid-phase microextraction and high-performance liquid chromatography with UV detection.

    PubMed

    Kumar, Ashwini; Singh, Baldev; Malik, Ashok Kumar; Tiwary, Dhananjay K

    2007-01-01

    A new approach has been developed for the extraction and determination of aldehydes such as veratraldehyde, m-nitrobenzaldehyde, cinnamaldehyde, benzaldehyde, and p-chlorobenzaldehyde by using solid-phase microextraction (SPME) and high-performance liquid chromatography with UV detection (HPLC/UV). The method involves adsorption of the aldehydes on polydimethylsiloxane/divinylbenzene-coated fiber, followed by desorption in the desorption chamber of the SPME-HPLC interface, using acetonitrile-water (70 + 30) as the mobile phase; UV detection was at 254 nm. A good separation of 5 aldehydes was obtained on a C18 column. The detection limits of veratraldehyde, m-nitrobenzaldehyde, cinnamaldehyde, benzaldehyde, and p-chlorobenzaldehyde are 25, 41, 13, 12, and 11 pg/mL, respectively, which are about 100 times better than the detection limits for other SPME methods using gas chromatography. The proposed method was validated by determining benzaldehyde in bitter almonds and cinnamaldehyde in cinnamon bark. The recoveries of the 5 analytes were determined by analysis of spiked drinking water.

  16. Determination of BPA, BPB, BPF, BADGE and BFDGE in canned energy drinks by molecularly imprinted polymer cleaning up and UPLC with fluorescence detection.

    PubMed

    Gallo, Pasquale; Di Marco Pisciottano, Ilaria; Esposito, Francesco; Fasano, Evelina; Scognamiglio, Gelsomina; Mita, Gustavo Damiano; Cirillo, Teresa

    2017-04-01

    A new method for simultaneous determination of five bisphenols in canned energy drinks by UPLC with fluorescence detection, after clean up on molecularly imprinted polymers, is herein described. The method was validated at two concentration levels, calculating trueness, repeatability and within-laboratory reproducibility, specificity, linearity of detector response, the limits of quantifications and the limits of detection for each bisphenol. The method is specific, reliable and very sensitive, allowing for determination of bisphenol F diglycidyl ether (BFDGE), bisphenol A (BPA), bisphenol B (BPB), bisphenol F (BPF) and bisphenol A diglycidyl ether (BADGE) down to 0.50ng/mL; it was employed to determine contamination levels from these bisphenols in forty energy drinks of different brands, collected from the market in Naples. BPA was detected in 17 out of 40 samples (42.5%); in some energy drinks also BPF, BADGE and BFDGE were determined. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. Determination of target detection limits in hyperspectral data using band selection and dimensionality reduction

    NASA Astrophysics Data System (ADS)

    Gross, W.; Boehler, J.; Twizer, K.; Kedem, B.; Lenz, A.; Kneubuehler, M.; Wellig, P.; Oechslin, R.; Schilling, H.; Rotman, S.; Middelmann, W.

    2016-10-01

    Hyperspectral remote sensing data can be used for civil and military applications to robustly detect and classify target objects. High spectral resolution of hyperspectral data can compensate for the comparatively low spatial resolution, which allows for detection and classification of small targets, even below image resolution. Hyperspectral data sets are prone to considerable spectral redundancy, affecting and limiting data processing and algorithm performance. As a consequence, data reduction strategies become increasingly important, especially in view of near-real-time data analysis. The goal of this paper is to analyze different strategies for hyperspectral band selection algorithms and their effect on subpixel classification for different target and background materials. Airborne hyperspectral data is used in combination with linear target simulation procedures to create a representative amount of target-to-background ratios for evaluation of detection limits. Data from two different airborne hyperspectral sensors, AISA Eagle and Hawk, are used to evaluate transferability of band selection when using different sensors. The same target objects were recorded to compare the calculated detection limits. To determine subpixel classification results, pure pixels from the target materials are extracted and used to simulate mixed pixels with selected background materials. Target signatures are linearly combined with different background materials in varying ratios. The commonly used classification algorithms Adaptive Coherence Estimator (ACE) is used to compare the detection limit for the original data with several band selection and data reduction strategies. The evaluation of the classification results is done by assuming a fixed false alarm ratio and calculating the mean target-to-background ratio of correctly detected pixels. The results allow drawing conclusions about specific band combinations for certain target and background combinations. Additionally, generally useful wavelength ranges are determined and the optimal amount of principal components is analyzed.

  18. THE USE AND LIMITATIONS OF DETECTION AND QUANTITATION LIMITS IN ENVIRONMENTAL ANALYSIS

    EPA Science Inventory

    Site assessment, remediation and compliance monitoring require the routine determination of the concentration of regulated substances in environmental samples. Each measurement methodology providing the concentration determinations, is required to specify key data quality elemen...

  19. Limit of detection of 15{sub N} by gas-chromatography atomic emission detection: Optimization using an experimental design

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Deruaz, D.; Bannier, A.; Pionchon, C.

    1995-08-01

    This paper deals with the optimal conditions for the detection of {sup 15}N determined using a four-factor experimental design from [2{sup 13}C,-1,3 {sup 15}N] caffeine measured with an atomic emission detector (AED) coupled to gas chromatography (GC). Owing to the capability of a photodiodes array, AED can simultaneously detect several elements using their specific emission lines within a wavelength range of 50 nm. So, the emissions of {sup 15}N and {sup 14}N are simultaneously detected at 420.17 nm and 421.46 nm respectively. Four independent experimental factors were tested (1) helium flow rate (plasma gas); (2) methane pressure (reactant gas); (3)more » oxygen pressure; (4) hydrogen pressure. It has been shown that these four gases had a significant influence on the analytical response of {sup 15}N. The linearity of the detection was determined using {sup 15}N amounts ranging from 1.52 pg to 19 ng under the optimal conditions obtained from the experimental design. The limit of detection was studied using different methods. The limits of detection of {sup 15}N was 1.9 pg/s according to the IUPAC method (International-Union of Pure and Applied Chemistry). The method proposed by Quimby and Sullivan gave a value of 2.3 pg/s and that of Oppenheimer gave a limit of 29 pg/s. For each determination, and internal standard: 1-isobutyl-3.7 dimethylxanthine was used. The results clearly demonstrate that GC AED is sensitive and selective enough to detect and measure {sup 15}N-labelled molecules after gas chromatographic separation.« less

  20. Method for early detection of cooling-loss events

    DOEpatents

    Bermudez, Sergio A.; Hamann, Hendrik; Marianno, Fernando J.

    2015-06-30

    A method of detecting cooling-loss event early is provided. The method includes defining a relative humidity limit and change threshold for a given space, measuring relative humidity in the given space, determining, with a processing unit, whether the measured relative humidity is within the defined relative humidity limit, generating a warning in an event the measured relative humidity is outside the defined relative humidity limit and determining whether a change in the measured relative humidity is less than the defined change threshold for the given space and generating an alarm in an event the change is greater than the defined change threshold.

  1. Method for early detection of cooling-loss events

    DOEpatents

    Bermudez, Sergio A.; Hamann, Hendrik F.; Marianno, Fernando J.

    2015-12-22

    A method of detecting cooling-loss event early is provided. The method includes defining a relative humidity limit and change threshold for a given space, measuring relative humidity in the given space, determining, with a processing unit, whether the measured relative humidity is within the defined relative humidity limit, generating a warning in an event the measured relative humidity is outside the defined relative humidity limit and determining whether a change in the measured relative humidity is less than the defined change threshold for the given space and generating an alarm in an event the change is greater than the defined change threshold.

  2. Determination of sulphite in wines using suppressed ion chromatography.

    PubMed

    Yoshikawa, Kenji; Uekusa, Yuki; Sakuragawa, Akio

    2015-05-01

    Suppressed ion chromatography with the use of a conductivity detector was developed for the determination of sulphite ions in wine samples. When a mixed solution of sodium carbonate, sodium bicarbonate, and acetone was used as the mobile phase, simultaneous determination of eight inorganic anions (i.e., fluoride, chloride, nitrite, nitrate, sulphite, phosphate, sulphate, and thiosulphate) was completed in approximately 25 min. Linearity, reproducibility, and detection limits were determined for the proposed method. In the case of sulphite detection, a linear calibration curve with a good correlation coefficient of 0.9992 was obtained from the peak height of sulphite with a relative standard deviation (n = 6) 1.48%. In addition, the detection limit of sulphite was 0.27 mg/L at a signal-to-noise ratio of 3. Further, the developed method was applied for the determination of sulphite contained in several wine samples. Copyright © 2014 Elsevier Ltd. All rights reserved.

  3. ON COMPUTING UPPER LIMITS TO SOURCE INTENSITIES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kashyap, Vinay L.; Siemiginowska, Aneta; Van Dyk, David A.

    2010-08-10

    A common problem in astrophysics is determining how bright a source could be and still not be detected in an observation. Despite the simplicity with which the problem can be stated, the solution involves complicated statistical issues that require careful analysis. In contrast to the more familiar confidence bound, this concept has never been formally analyzed, leading to a great variety of often ad hoc solutions. Here we formulate and describe the problem in a self-consistent manner. Detection significance is usually defined by the acceptable proportion of false positives (background fluctuations that are claimed as detections, or Type I error),more » and we invoke the complementary concept of false negatives (real sources that go undetected, or Type II error), based on the statistical power of a test, to compute an upper limit to the detectable source intensity. To determine the minimum intensity that a source must have for it to be detected, we first define a detection threshold and then compute the probabilities of detecting sources of various intensities at the given threshold. The intensity that corresponds to the specified Type II error probability defines that minimum intensity and is identified as the upper limit. Thus, an upper limit is a characteristic of the detection procedure rather than the strength of any particular source. It should not be confused with confidence intervals or other estimates of source intensity. This is particularly important given the large number of catalogs that are being generated from increasingly sensitive surveys. We discuss, with examples, the differences between these upper limits and confidence bounds. Both measures are useful quantities that should be reported in order to extract the most science from catalogs, though they answer different statistical questions: an upper bound describes an inference range on the source intensity, while an upper limit calibrates the detection process. We provide a recipe for computing upper limits that applies to all detection algorithms.« less

  4. HPLC separation post-column reaction, UV-visible and fluorescence detection of trace UO/sub 2//sup 2 +//U/sup 4 +/ species in aqueous solutions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Karimi, A.R.

    In this study a method for the measurement of uranium in natural waters at sub-ppB concentration levels by the separation and determination of U/sup 4 +/ and UO/sub 2//sup 2 +/ species is proposed. Reversed phase high performance liquid chromatography, followed by a post-column reaction and a sensitive UV-visible detection system was the method of choice to determine qualitatively and quantitatively the two uranium species. Also a cation-exchange and fluorescence detection system was studied for separation and determination of UO/sub 2//sup 2 +/ ions. Uranyl ion was selectively complexed with L-phenylalanine moetie in the sample solution containing U/sup 4 +/more » ions. Uranium (IV)/U(VI)-ligand was separated on a C/sub 18/ column with acetate buffer. Hexanesulfonate was found to be the choice for ion-pair reagent. The separation was best done with the acetate buffer at .01 M concentration and pH of 3.5. Absorption of the two species were measured after a post-column reaction with Arsenazo-III. Chromatographic parameters were calculated and a calibration curves were constructed. The detection limit for the procedure was 0.7 ..mu..g/mo and 1.2..mu..g/ml for U(IV) and U(VI) respectively. When U(VI) was separated on the cation-exchange column the limit of detection was calculated to be 1 ..mu..g/ml. The direct fluorometric method for U(VI) measurement results in a detection limit of 2 ppB and upper concentration limit of 2 ppM. The effect of interfering ions in the direct method of determination could be eliminated by dilution of sample solution.« less

  5. Failure detection system risk reduction assessment

    NASA Technical Reports Server (NTRS)

    Aguilar, Robert B. (Inventor); Huang, Zhaofeng (Inventor)

    2012-01-01

    A process includes determining a probability of a failure mode of a system being analyzed reaching a failure limit as a function of time to failure limit, determining a probability of a mitigation of the failure mode as a function of a time to failure limit, and quantifying a risk reduction based on the probability of the failure mode reaching the failure limit and the probability of the mitigation.

  6. Enantioselective determination of the organochlorine pesticide bromocyclen in spiked fish tissue using solid-phase microextraction coupled to gas chromatography with ECD and ICP-MS detection.

    PubMed

    Fidalgo-Used, Natalia; Montes-Bayón, Maria; Blanco-González, Elisa; Sanz-Medel, Alfredo

    2008-05-15

    A method for enantioselective determination of bromocyclen enantiomers in fish tissue has been developed. The enantiomers were resolved by capillary gas chromatography (GC) using a commercial chiral column (CP-Chirasil-Dex CB) and a temperature program from 50 degrees C (held for 1 min), raised to 140 degrees C at 40 degrees C min(-1) and then raised at 0.2 degrees C min(-1) to 155 degrees C. This enantioselective gas chromatographic separation was combined with a clean-up/enrichment procedure based on solid-phase microextraction (SPME). Under SPME optimized conditions, precision, linearity range and detection limits of the developed SPME-enantioselective GC procedure were evaluated and compared using two different detection systems: a classical electron-capture detection (ECD) and an element specific detection using inductively coupled plasma mass spectrometry (ICP-MS). The SPME-GC-ECD method exhibited an excellent sensitivity, with detection limits of 0.2 ng L(-1) for each enantiomer of bromocyclen. Although ICP-MS offered poorer detection limits (7 ng L(-1) as Br, equivalent to 36 ng L(-1) of each enantiomer) than conventional ECD detector, it proved to be clearly superior in terms of selectivity. The relative potential and performance of the two compared methods for real-life analysis has been illustrated by the determination of enantiomers of bromocyclen in spiked tissue extracts of trout.

  7. SYSTEM OPTIMIZATION FOR THE AUTOMATIC SIMULTANEOUS DETERMINATION OF ARSENIC, SELENIUM, AND ANTIMONY, USING HYDRIDE GENERATION INTRODUCTION TO AN INDUCTIVELY COUPLED PLASMA.

    USGS Publications Warehouse

    Pyen, Grace S.; Browner, Richard F.; Long, Stephen

    1986-01-01

    A fixed-size simplex has been used to determine the optimum conditions for the simultaneous determination of arsenic, selenium, and antimony by hydride generation and inductively coupled plasma emission spectrometry. The variables selected for the simplex were carrier gas flow rate, rf power, viewing height, and reagent conditions. The detection limit for selenium was comparable to the preoptimized case, but there were twofold and fourfold improvements in the detection limits for arsenic and antimony, respectively. Precision of the technique was assessed with the use of artificially prepared water samples.

  8. Evaluation of statistical treatments of left-censored environmental data using coincident uncensored data sets: I. Summary statistics

    USGS Publications Warehouse

    Antweiler, Ronald C.; Taylor, Howard E.

    2008-01-01

    The main classes of statistical treatment of below-detection limit (left-censored) environmental data for the determination of basic statistics that have been used in the literature are substitution methods, maximum likelihood, regression on order statistics (ROS), and nonparametric techniques. These treatments, along with using all instrument-generated data (even those below detection), were evaluated by examining data sets in which the true values of the censored data were known. It was found that for data sets with less than 70% censored data, the best technique overall for determination of summary statistics was the nonparametric Kaplan-Meier technique. ROS and the two substitution methods of assigning one-half the detection limit value to censored data or assigning a random number between zero and the detection limit to censored data were adequate alternatives. The use of these two substitution methods, however, requires a thorough understanding of how the laboratory censored the data. The technique of employing all instrument-generated data - including numbers below the detection limit - was found to be less adequate than the above techniques. At high degrees of censoring (greater than 70% censored data), no technique provided good estimates of summary statistics. Maximum likelihood techniques were found to be far inferior to all other treatments except substituting zero or the detection limit value to censored data.

  9. Simultaneous determination of residues of emamectin and its metabolites, and milbemectin, ivermectin, and abamectin in crops by liquid chromatography with fluorescence detection.

    PubMed

    Yoshii, K; Kaihara, A; Tsumura, Y; Ishimitsu, S; Tonogai, Y

    2001-01-01

    A liquid chromatographic (LC) method was developed for the determination of emamectin and its metabolites (8,9-Z-isomer, N-demethylated, N-formylated, and N-methylformylated emamectin) in various crops. The analytes were extracted with acetone, cleaned up on cartridge columns (C18 and NH2), derivatized with trifluoroacetic anhydride and 1-methylimidazole, and determined by LC with fluorescence detection. Because radish inhibited the formation of the fluorescent derivatives, an additional Bond Elut PRS cartridge was used in the cleanup of Japanese radish samples. During sample preparation, N-formylated emamectin partially degraded to emamectin B1b and emamectin B1a, and the 8,9-Z-isomer partially degraded to N-demethylated emamectin. Therefore, emamectin and its metabolites were determined as total emamectin, i.e., their sum was estimated as emamectin benzoate. Their recoveries from most crops were approximately 80-110% with the developed method. The detection limits for the analytes in vegetables were 0.1-0.3 parts per trillion (ppt). The results for these compounds were confirmed by LC/mass spectrometry (LC/MS; electrospray ionization mode). Because the fluorescent derivative of emamectin was undetectable by LC/MS, the results for the analyte were confirmed by using a sample solution without derivatization. Limits of detection by LC/MS were similar to the fluorescence detection limits, 0.1-0.3 ppt in vegetables. In addition to the emamectins, milbemectin, ivermectin, and abamectin were also determined by the developed method.

  10. The limit of detection in scintigraphic imaging with I-131 in patients with differentiated thyroid carcinoma

    NASA Astrophysics Data System (ADS)

    Hänscheid, H.; Lassmann, M.; Buck, A. K.; Reiners, C.; Verburg, F. A.

    2014-05-01

    Radioiodine scintigraphy influences staging and treatment in patients with differentiated thyroid carcinoma. The limit of detection for fractional uptake in an iodine avid focus in a scintigraphic image was determined from the number of lesion net counts and the count density of the tissue background. The count statistics were used to calculate the diagnostic activity required to elevate the signal from a lesion with a given uptake significantly above a homogeneous background with randomly distributed counts per area. The dependences of the minimal uptake and the minimal size of lesions visible in a scan on several parameters of influence were determined by linking the typical biokinetics observed in iodine avid tissue to the lesion mass and to the absorbed dose received in a radioiodine therapy. The detection limits for fractional uptake in a neck lesion of a typical patient are about 0.001% after therapy with 7000 MBq, 0.01% for activities typically administered in diagnostic assessments (74-185 MBq), and 0.1% after the administration of 10 MBq I-131. Lesions at the limit of detection in a diagnostic scan with biokinetics eligible for radioiodine therapy are small with diameters of a few millimeters. Increasing the diagnostic activity by a factor of 4 reduces the diameter of visible lesions by 25% or about 1 mm. Several other determinants have a comparable or higher influence on the limit of detection than the administered activity; most important are the biokinetics in both blood pool and target tissue and the time of measurement. A generally valid recommendation for the timing of the scan is impossible as the time of the highest probability to detect iodine avid tissue depends on the administered activity as well as on the biokinetics in the lesion and background in the individual patient.

  11. Quantitative analysis of trace levels of surface contamination by X-ray photoelectron spectroscopy Part I: statistical uncertainty near the detection limit.

    PubMed

    Hill, Shannon B; Faradzhev, Nadir S; Powell, Cedric J

    2017-12-01

    We discuss the problem of quantifying common sources of statistical uncertainties for analyses of trace levels of surface contamination using X-ray photoelectron spectroscopy. We examine the propagation of error for peak-area measurements using common forms of linear and polynomial background subtraction including the correlation of points used to determine both background and peak areas. This correlation has been neglected in previous analyses, but we show that it contributes significantly to the peak-area uncertainty near the detection limit. We introduce the concept of relative background subtraction variance (RBSV) which quantifies the uncertainty introduced by the method of background determination relative to the uncertainty of the background area itself. The uncertainties of the peak area and atomic concentration and of the detection limit are expressed using the RBSV, which separates the contributions from the acquisition parameters, the background-determination method, and the properties of the measured spectrum. These results are then combined to find acquisition strategies that minimize the total measurement time needed to achieve a desired detection limit or atomic-percentage uncertainty for a particular trace element. Minimization of data-acquisition time is important for samples that are sensitive to x-ray dose and also for laboratories that need to optimize throughput.

  12. ENVIRONMENTAL APPLICATION OF GAS CHROMATOGRAPHY/ATOMIC EMISSION DETECTION

    EPA Science Inventory

    A gas chromatography/atomic emission detector (GC/AED) system has been evaluated for its applicability to environmental analysis. Detection limits, elemental response factors, and regression analysis data were determined for 58 semivolatile environmental contaminants. Detection l...

  13. 78 FR 33110 - Certain Electronic Digital Media Devices and Components Thereof; Determination To Review a Remand...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-03

    ... construction of the claims added during reissue? In particular, please comment on the applicability of the... proffered claim construction argument that construes the claim limitation ``to detect that the signal path... proposed construction of the claimed detection circuitry limitation is adopted (see Apple Pet. at 69-76...

  14. Determination of bisphenol A in food-simulating liquids using LCED with a chemically modified electrode.

    PubMed

    D'Antuono, A; Dall'Orto, V C; Lo Balbo, A; Sobral, S; Rezzano, I

    2001-03-01

    Liquid chromatography with electrochemical detector (LC-ED), using a chemically modified electrode coated with a metalloporphyrin film, is reported for determination of bisphenol A (BPA) migration from polycarbonate baby bottles. The extraction process of the samples was performed according to regulations of the Southern Common Market (MERCOSUR), where certain food-simulating liquids [(A) distilled water, (B) acetic acid 3% V/V in distilled water, and (C) ethanol 15% V/V in distilled water] are defined along with controlled time and temperature conditions. The baseline obtained using the naked electrode showed a considerable drift which increased the detection limit. This effect was suppressed with the chemically modified electrode. A linear range up to 450 ppb along with a detection limit of 20 ppb for the amperometric detection technique was observed. The procedure described herein allowed lowering the detection limit of the method to 0.2 ppb. The value found for BPA in the food-simulating liquid is 1.2 ppb, which is below the tolerance limit for specific migration (4.8 ppm).

  15. Determination of glucosinolates in rapeseed and Thlaspi caerulescens plants by liquid chromatography-atmospheric pressure chemical ionization mass spectrometry.

    PubMed

    Tolrà, R P; Alonso, R; Poschenrieder, C; Barceló, D; Barceló, J

    2000-08-11

    Liquid chromatography-atmospheric pressure chemical ionization mass spectrometry was used to identify glucosinolates in plant extracts. Optimization of the analytical conditions and the determination of the method detection limit was performed using commercial 2-propenylglucosinolate (sinigrin). Optimal values for the following parameters were determined: nebulization pressure, gas temperature, flux of drying gas, capillar voltage, corona current and fragmentor conditions. The method detection limit for sinigrin was 2.85 ng. For validation of the method the glucosinolates in reference material (rapeseed) from the Community Bureau of Reference Materials (BCR) were analyzed. The method was applied for the determination of glucosinolates in Thlaspi caerulescens plants.

  16. Amperometric determination of nitrite using natural fibers as template for titanium dioxide nanotubes with immobilized hemin as electron transfer mediator.

    PubMed

    Ranjani, Balasubramanian; Kalaiyarasi, Jayaprakasham; Pavithra, Loganathan; Devasena, Thiyagarajan; Pandian, Kannaiyan; Gopinath, Subash C B

    2018-02-23

    A sensing device was constructed for the amperometric determination of nitrite. It is based on the use of titanium dioxide (TiO 2 ) nanotubes template with natural fibers and carrying hemin acting as the electron mediator. A glassy carbon electrode (GCE) was modified with the hemin/TNT nanocomposite. The electrochemical response to nitrite was characterized by impedance spectroscopy and cyclic voltammetry. An amperometric study, performed at a working potential of + 0.75 V (vs. Ag/AgCl), showed the sensor to enable determination of nitrite with a linear response in the 0.6 to 130 μM concentration range and with a 59 nM limit of detection. Corresponding studies by differential study voltammetry (E p  = 0.75 V) exhibited a linear range from 0.6 × 10 -6 to 7.3 × 10 -5  M with a limit of detection of 84 nM. The sensing device was applied to the determination of nitrite in spiked tap and lake water samples. Graphical abstract Natural fibers templated synthesis of TNT immobilized hemin as electron transfer mediator for quantitative detection of nitrite with detection limit of 59 nM and good electrochemical sensitivity and the method can be used for quantitative determination of nitrite in water samples.

  17. Ultrasensitive Detection of Shigella Species in Blood and Stool.

    PubMed

    Luo, Jieling; Wang, Jiapeng; Mathew, Anup S; Yau, Siu-Tung

    2016-02-16

    A modified immunosensing system with voltage-controlled signal amplification was used to detect Shigella in stool and blood matrixes at the single-digit CFU level. Inactivated Shigella was spiked in these matrixes and detected directly. The detection was completed in 78 min. Detection limits of 21 CFU/mL and 18 CFU/mL were achieved in stool and blood, respectively, corresponding to 2-7 CFUs immobilized on the detecting electrode. The outcome of the detection of extremely low bacterium concentration, i.e., below 100 CFU/mL, blood samples show a random nature. An analysis of the detection probabilities indicates the correlation between the sample volume and the success of detection and suggests that sample volume is critical for ultrasensitive detection of bacteria. The calculated detection limit is qualitatively in agreement with the empirically determined detection limit. The demonstrated ultrasensitive detection of Shigella on the single-digit CFU level suggests the feasibility of the direct detection of the bacterium in the samples without performing a culture.

  18. Real-Time Detection of Telomerase in a Microelectromechanical Systems Platform

    DTIC Science & Technology

    2005-05-01

    contains color images. 14. ABSTRACT 15. SUBJECT TERMS 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT UU 18. NUMBER OF PAGES 147 19a...Telomerase accomplishes this by alleviating the “end-replication problem” (6,10,14,23,33,43). First described by Hayflick in 1965, the end-replication...were produced to determine the minimum detection limit of the ABI Prism 7000 as an optical fluorescent detection device. In addition, I wanted to

  19. An improved method for undertaking limiting dilution assays for in vitro cloning of Plasmodium falciparum parasites.

    PubMed

    Butterworth, Alice S; Robertson, Alan J; Ho, Mei-Fong; Gatton, Michelle L; McCarthy, James S; Trenholme, Katharine R

    2011-04-18

    Obtaining single parasite clones is required for many techniques in malaria research. Cloning by limiting dilution using microscopy-based assessment for parasite growth is an arduous and labor-intensive process. An alternative method for the detection of parasite growth in limiting dilution assays is using a commercial ELISA histidine-rich protein II (HRP2) detection kit. Detection of parasite growth was undertaken using HRP2 ELISA and compared to thick film microscopy. An HRP2 protein standard was used to determine the detection threshold of the HRP2 ELISA assay, and a HRP2 release model was used to extrapolate the amount of parasite growth required for a positive result. The HRP2 ELISA was more sensitive than microscopy for detecting parasite growth. The minimum level of HRP2 protein detection of the ELISA was 0.11 ng/ml. Modeling of HRP2 release determined that 2,116 parasites are required to complete a full erythrocytic cycle to produce sufficient HRP2 to be detected by the ELISA. Under standard culture conditions this number of parasites is likely to be reached between 8 to 14 days of culture. This method provides an accurate and simple way for the detection of parasite growth in limiting dilution assays, reducing time and resources required in traditional methods. Furthermore the method uses spent culture media instead of the parasite-infected red blood cells, enabling culture to continue. © 2011 Butterworth et al; licensee BioMed Central Ltd.

  20. Simultaneous determination of seven multiclass veterinary antibiotics in surface water samples in the Republic of Korea using liquid chromatography with tandem mass spectrometry.

    PubMed

    Chung, Hyung Suk; Choi, Jeong-Heui; Abd El-Aty, A M; Lee, Young-Jun; Lee, Han Sol; Kim, Sangdon; Jung, Hee-Jung; Kang, Tae-Woo; Shin, Ho-Chul; Shim, Jae-Han

    2016-12-01

    A simultaneous determination method using solid-phase extraction and liquid chromatography with tandem mass spectrometry was developed to detect and quantify the presence of seven multiclass veterinary antibiotics (13 compounds in total) in surface water samples, which included the effluents of livestock wastewater and sewage treatment plants, as well as the reservoir drainage areas from dense animal farms. The pH of all water samples was adjusted to 2 or 6 before solid-phase extraction using Oasis HLB cartridges. The developed method was fully validated in terms of linearity, method detection limit, method quantitation limit, accuracy, and precision. The linearity of all tested drugs was good, with R 2 determination coefficients ≥ 0.9931. The method detection limits and method quantitation limits were 0.1-74.3 and 0.5-236.6 ng/L, respectively. Accuracy and precision values were 71-120 and 1-17%, respectively. The determination method was successfully applied for monitoring water samples obtained from the Yeongsan River in 2015. The most frequently detected antibiotics were lincomycin (96%), sulfamethazine (90%), sulfamethoxazole (88%), and sulfathiazole (50%); the maximum concentrations of which were 398.9, 1151.3, 533.1, and 307.4 ng/L, respectively. Overall, the greatest numbers and concentrations of detected antibiotics were found in samples from the effluents of livestock wastewater, sewage treatment plants, and reservoir drainage areas. Diverse veterinary antibiotics were present, and their presence was dependent upon the commercial sales and environmental properties of the analytes, the geographical positions of the sampling points, and the origin of the water. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Iron pentacarbonyl detection limits in the cigarette smoke matrix using FT-IR spectroscopy

    NASA Astrophysics Data System (ADS)

    Parrish, Milton E.; Plunkett, Susan E.; Harward, Charles N.

    2005-11-01

    Endogenous metals present in tobacco from agricultural practices have been purported to generate metal carbonyls in cigarette smoke. Transition metal catalysts, such as iron oxide, have been investigated for the reduction of carbon monoxide (CO) in cigarette smoke. These studies motivated the development of an analytical method to determine if iron pentacarbonyl [Fe(CO) 5] is present in mainstream smoke from cigarette models having cigarette paper made with iron oxide. An FT-IR puff-by-puff method was developed and the detection limit was determined using two primary reference spectra from different sources to estimate the amount of Fe(CO) 5 present in a high-pressure steel cylinder of CO. We do not detect Fe(CO) 5 in a single 35 mL puff from reference cigarettes or from those cigarette models having cigarette paper made with iron oxide, with a 30-ppbV limit of detection (LOD). Also, it was shown that a filter containing activated carbon would remove Fe(CO) 5.

  2. Determination of pentachlorophenol in water and aquifer sediments by high-performance liquid chromatography

    USGS Publications Warehouse

    Goerlitz, D.F.

    1981-01-01

    Methods for the determination of pentachlorophenol (PCP) in water and aquifer sediments are presented. Reverse-phase high-performance liquid chromotography employing ion suppression and gradient elution is used. PCP can be determined directly in water at a lower limit of detection Of 0.2 micrograms per liter. For extracts of sediment, PCP can be determined to a lower limit of 1.0 micrograms per kilogram.

  3. Determination of the cyanobacterial toxin cylindrospermopsin in algal food supplements.

    PubMed

    Liu, H; Scott, P M

    2011-06-01

    For the analysis of blue-green algal food supplements for cylindrospermopsin (CYN), a C18 solid-phase extraction column and a polygraphitized carbon solid-phase extraction column in series was an effective procedure for the clean-up of extracts. Determination of CYN was by liquid chromatography with ultraviolet light detection. At extract spiking levels of CYN equivalent to 25-500 µg g(-1), blue-green algal supplement recoveries were in the range 70-90%. CYN was not detected in ten samples of food supplements and one chocolate product, all containing blue-green algae. The limit of detection for the method was 16 µg g(-1), and the limit of quantification was 52 µg g(-1).

  4. Detection limit for rate fluctuations in inhomogeneous Poisson processes

    NASA Astrophysics Data System (ADS)

    Shintani, Toshiaki; Shinomoto, Shigeru

    2012-04-01

    Estimations of an underlying rate from data points are inevitably disturbed by the irregular occurrence of events. Proper estimation methods are designed to avoid overfitting by discounting the irregular occurrence of data, and to determine a constant rate from irregular data derived from a constant probability distribution. However, it can occur that rapid or small fluctuations in the underlying density are undetectable when the data are sparse. For an estimation method, the maximum degree of undetectable rate fluctuations is uniquely determined as a phase transition, when considering an infinitely long series of events drawn from a fluctuating density. In this study, we analytically examine an optimized histogram and a Bayesian rate estimator with respect to their detectability of rate fluctuation, and determine whether their detectable-undetectable phase transition points are given by an identical formula defining a degree of fluctuation in an underlying rate. In addition, we numerically examine the variational Bayes hidden Markov model in its detectability of rate fluctuation, and determine whether the numerically obtained transition point is comparable to those of the other two methods. Such consistency among these three principled methods suggests the presence of a theoretical limit for detecting rate fluctuations.

  5. Detection limit for rate fluctuations in inhomogeneous Poisson processes.

    PubMed

    Shintani, Toshiaki; Shinomoto, Shigeru

    2012-04-01

    Estimations of an underlying rate from data points are inevitably disturbed by the irregular occurrence of events. Proper estimation methods are designed to avoid overfitting by discounting the irregular occurrence of data, and to determine a constant rate from irregular data derived from a constant probability distribution. However, it can occur that rapid or small fluctuations in the underlying density are undetectable when the data are sparse. For an estimation method, the maximum degree of undetectable rate fluctuations is uniquely determined as a phase transition, when considering an infinitely long series of events drawn from a fluctuating density. In this study, we analytically examine an optimized histogram and a Bayesian rate estimator with respect to their detectability of rate fluctuation, and determine whether their detectable-undetectable phase transition points are given by an identical formula defining a degree of fluctuation in an underlying rate. In addition, we numerically examine the variational Bayes hidden Markov model in its detectability of rate fluctuation, and determine whether the numerically obtained transition point is comparable to those of the other two methods. Such consistency among these three principled methods suggests the presence of a theoretical limit for detecting rate fluctuations.

  6. The sequential injection system with adsorptive stripping voltammetric detection.

    PubMed

    Kubiak, W W; Latonen, R M; Ivaska, A

    2001-03-16

    Two sequential injection systems have been developed for adsorptive stripping voltammetric measurement. One is for substances adsorbing at mercury, e.g. riboflavin. In this case, a simple arrangement with only sample aspiration is needed. Reproducibility was 3% and detection limit 0.07 muM. The measuring system was applied to determination of riboflavin in vitamin pills and to study the photodegradation process of riboflavin in aqueous solutions. In the second case, metal ions were determined. They have to be complexed before deposition on the mercury surface. Thus, both the sample and the ligand have to be aspirated in the system. In this case, the reproducibility was approximately 6% and the detection limit <0.1 ppm for cadmium, lead and copper when complexation with oxine was used. Dimethylglyoxime was used in determination of nickel and cobalt and nioxime complexes were used in determination of nickel and copper. With these complexing agents, the reproducibility was the same as with oxine, but the metals could be determined at concentrations lower than 0.01 ppm. Application of two ligands in a SIA system with AdSV detection was also studied. Simultaneous determination of copper, lead, cadmium and cobalt was possible by using oxine and dimethylglyoxime. Copper and nickel were simultaneously determined by using dimethylglyoxime and nioxime.

  7. Fundamentals of Counting Statistics in Digital PCR: I Just Measured Two Target Copies-What Does It Mean?

    PubMed

    Tzonev, Svilen

    2018-01-01

    Current commercially available digital PCR (dPCR) systems and assays are capable of detecting individual target molecules with considerable reliability. As tests are developed and validated for use on clinical samples, the need to understand and develop robust statistical analysis routines increases. This chapter covers the fundamental processes and limitations of detecting and reporting on single molecule detection. We cover the basics of quantification of targets and sources of imprecision. We describe the basic test concepts: sensitivity, specificity, limit of blank, limit of detection, and limit of quantification in the context of dPCR. We provide basic guidelines how to determine those, how to choose and interpret the operating point, and what factors may influence overall test performance in practice.

  8. Development of capillary electrophoresis methods for quantitative determination of taurine in vehicle system and biological media.

    PubMed

    da Silva, Dayse L P; Rüttinger, Hans H; Mrestani, Yahia; Baum, Walter F; Neubert, Reinhard H H

    2006-06-01

    CE methods have been developed for the determination of taurine in pharmaceutical formulation (microemulsion) and in biological media such as sweat. The CE system with end-column pulsed amperometric detection has been found to be an interesting method in comparison with UV and fluorescence detection for its simplicity and rapidity. A gold-disk electrode of 100 mm diameter was used as the working electrode. The effects of a field decoupler at the end of the capillary, separation voltage, injection and pressure times were investigated. A detection limit of 4 x 10(-5) mol/L was reached using integrated pulsed amperometric detection, a method successfully applied to taurine analysis of the biological samples such as sweat. For taurine analysis of oil-in-water microemulsion, fluorescence detector was the favored method, the detection limit of which was 4 x 10(-11) mol/L.

  9. Effects of capacity limits, memory loss, and sound type in change deafness.

    PubMed

    Gregg, Melissa K; Irsik, Vanessa C; Snyder, Joel S

    2017-11-01

    Change deafness, the inability to notice changes to auditory scenes, has the potential to provide insights about sound perception in busy situations typical of everyday life. We determined the extent to which change deafness to sounds is due to the capacity of processing multiple sounds and the loss of memory for sounds over time. We also determined whether these processing limitations work differently for varying types of sounds within a scene. Auditory scenes composed of naturalistic sounds, spectrally dynamic unrecognizable sounds, tones, and noise rhythms were presented in a change-detection task. On each trial, two scenes were presented that were same or different. We manipulated the number of sounds within each scene to measure memory capacity and the silent interval between scenes to measure memory loss. For all sounds, change detection was worse as scene size increased, demonstrating the importance of capacity limits. Change detection to the natural sounds did not deteriorate much as the interval between scenes increased up to 2,000 ms, but it did deteriorate substantially with longer intervals. For artificial sounds, in contrast, change-detection performance suffered even for very short intervals. The results suggest that change detection is generally limited by capacity, regardless of sound type, but that auditory memory is more enduring for sounds with naturalistic acoustic structures.

  10. Chloride interference in the determination of bromate in drinking water by reagent free ion chromatography with mass spectrometry detection.

    PubMed

    Cavalli, Silvano; Polesello, Stefano; Valsecchi, Sara

    2005-08-26

    Bromate, a well known by-product of the ozonation of drinking water, has been included among the substances which have to be monitored in the drinking water according to the last EC Directive 251/98 on potable water with a regulated limit of 10 microg l(-1). The need of performing routine analysis at this limit is a driving force for the developing of new simple and sensitive methods of detection, which should be also able to overcome the effect of matrix composition. This work explored the use of mass spectrometry detection with electrospray ionisation hyphenated to a reagent free ion chromatograph with hydroxide gradient elution for the determination of bromate in drinking water. The use of a high capacity hydroxide selective column operated in gradient mode allowed to avoid the interference by carbonate peak, which moved to longer retention times. The effect of increasing chloride concentrations from 0 to 250 mg l(-1), which is the guideline limit for drinking water in Directive 251/98/EC, was to decrease absolute mass spectrometric response and chromatographic efficiency and, on the consequence, to increase the effective detection limits. The effect of the chloride concentration on the detection of bromate is discussed.

  11. Strategies and limitations for fluorescence detection of XAFS at high flux beamlines

    DOE PAGES

    Heald, Steve M.

    2015-02-17

    The issue of detecting the XAFS signal from dilute samples is discussed in detail with the aim of making best use of high flux beamlines that provide up to 10 13 photons -1. Various detection methods are compared, including filters with slits, solid state detectors, crystal analyzers and combinations of these. These comparisons rely on simulations that use experimentally determined parameters. It is found that inelastic scattering places a fundamental limit on detection, and that it is important to take proper account of the polarization dependence of the signals. The combination of a filter–slit system with a solid state detectormore » is a promising approach. With an optimized system good performance can be obtained even if the total count rate is limited to 10 7 Hz. Detection schemes with better energy resolution can help at the largest dilutions if their collection efficiency and count rate limits can be improved.« less

  12. Strategies and limitations for fluorescence detection of XAFS at high flux beamlines

    PubMed Central

    Heald, Steve M.

    2015-01-01

    The issue of detecting the XAFS signal from dilute samples is discussed in detail with the aim of making best use of high flux beamlines that provide up to 1013 photons s−1. Various detection methods are compared, including filters with slits, solid state detectors, crystal analyzers and combinations of these. These comparisons rely on simulations that use experimentally determined parameters. It is found that inelastic scattering places a fundamental limit on detection, and that it is important to take proper account of the polarization dependence of the signals. The combination of a filter–slit system with a solid state detector is a promising approach. With an optimized system good performance can be obtained even if the total count rate is limited to 107 Hz. Detection schemes with better energy resolution can help at the largest dilutions if their collection efficiency and count rate limits can be improved. PMID:25723945

  13. Photometric Determination of Ammonium and Phosphate in Seawater Medium Using a Microplate Reader.

    PubMed

    Ruppersberg, Hanna S; Goebel, Maren R; Kleinert, Svea I; Wünsch, Daniel; Trautwein, Kathleen; Rabus, Ralf

    2017-01-01

    To more efficiently process the large sample numbers for quantitative determination of ammonium (NH4+) and phosphate (orthophosphate, PO43-) generated during comprehensive growth experiments with the marine Roseobacter group member Phaeobacter inhibens DSM 17395, specific colorimetric assays employing a microplate reader (MPR) were established. The NH4+ assay is based on the reaction of NH4+ with hypochlorite and salicylate, yielding a limit of detection of 14 µM, a limit of quantitation of 36 µM, and a linear range for quantitative determination up to 200 µM. The PO43-assay is based on the complex formation of PO43- with ammonium molybdate in the presence of ascorbate and zinc acetate, yielding a limit of detection of 13 µM, a limit of quantitation of 50 µM, and a linear range for quantitative determination up to 1 mM. Both MPR-based assays allowed for fast (significantly lower than 1 h) analysis of 21 samples plus standards for calibration (all measured in triplicates) and showed only low variation across a large collection of biological samples. © 2017 S. Karger AG, Basel.

  14. Determination of benzothiazole and benzotriazole derivates in tire and clothing textile samples by high performance liquid chromatography-electrospray ionization tandem mass spectrometry.

    PubMed

    Avagyan, Rozanna; Sadiktsis, Ioannis; Thorsén, Gunnar; Östman, Conny; Westerholm, Roger

    2013-09-13

    A high performance liquid chromatography-tandem mass spectrometry method utilizing electrospray ionization in positive and negative mode has been developed for the separation and detection of benzothiazole and benzotriazole derivates. Ultra-sonication assisted solvent extraction of these compounds has also been developed and the overall method demonstrated on a selected clothing textile and an automobile tire sample. Matrix effects and extraction recoveries, as well as linearity and limits of detection have been evaluated. The calibration curves spanned over more than two orders of magnitude with coefficients of correlation R(2)>0.99 and the limits of detection and the limits of quantification were in the range 1.7-58pg injected and 18-140pg/g, respectively. The extraction recoveries ranged between 69% and 102% and the matrix effects between 75% and 101%. Benzothiazole and benzotriazole derivates were determined in the textile sample and benzothiazole derivatives determined in the tire sample with good analytical performance. Copyright © 2013 Elsevier B.V. All rights reserved.

  15. Sensitive electrochemical sensors for simultaneous determination of ascorbic acid, dopamine, and uric acid based on Au@Pd-reduced graphene oxide nanocomposites

    NASA Astrophysics Data System (ADS)

    Jiang, Jingjing; Du, Xuezhong

    2014-09-01

    Sensitive electrochemical sensors were fabricated with reduced graphene oxide-supported Au@Pd (Au@Pd-RGO) nanocomposites by one-step synthesis for individual and simultaneous determination of ascorbic acid (AA), dopamine (DA), and uric acid (UA) with low detection limits and wide concentration ranges. From the Au@Pd-RGO-modified electrodes, well-separated oxidation peaks and enhanced peak currents of AA, DA, and UA were observed owing to the superior conductivity of RGO and the excellent catalytic activity of Au@Pd nanoparticles. For individual detection, the linear responses of AA, DA, and UA were in the concentration ranges of 0.1-1000, 0.01-100, and 0.02-500 μM with detection limits of 0.02, 0.002, and 0.005 μM (S/N = 3), respectively. For simultaneous detection by synchronous change of the concentrations of AA, DA, and UA, the linear response ranges were 1-800, 0.1-100, and 0.1-350 μM with detection limits of 0.28, 0.024, and 0.02 μM (S/N = 3), respectively. The fabricated sensors were further applied to the detection of AA, DA, and UA in urine samples. The Au@Pd-RGO nanocomposites have promising applications in highly sensitive and selective electrochemical sensing.Sensitive electrochemical sensors were fabricated with reduced graphene oxide-supported Au@Pd (Au@Pd-RGO) nanocomposites by one-step synthesis for individual and simultaneous determination of ascorbic acid (AA), dopamine (DA), and uric acid (UA) with low detection limits and wide concentration ranges. From the Au@Pd-RGO-modified electrodes, well-separated oxidation peaks and enhanced peak currents of AA, DA, and UA were observed owing to the superior conductivity of RGO and the excellent catalytic activity of Au@Pd nanoparticles. For individual detection, the linear responses of AA, DA, and UA were in the concentration ranges of 0.1-1000, 0.01-100, and 0.02-500 μM with detection limits of 0.02, 0.002, and 0.005 μM (S/N = 3), respectively. For simultaneous detection by synchronous change of the concentrations of AA, DA, and UA, the linear response ranges were 1-800, 0.1-100, and 0.1-350 μM with detection limits of 0.28, 0.024, and 0.02 μM (S/N = 3), respectively. The fabricated sensors were further applied to the detection of AA, DA, and UA in urine samples. The Au@Pd-RGO nanocomposites have promising applications in highly sensitive and selective electrochemical sensing. Electronic supplementary information (ESI) available: pH optimization, comparison of sensor performances, interference experiments, and detection in urine samples. See DOI: 10.1039/c4nr01774a

  16. Quantum Limits of Space-to-Ground Optical Communications

    NASA Technical Reports Server (NTRS)

    Hemmati, H.; Dolinar, S.

    2012-01-01

    For a pure loss channel, the ultimate capacity can be achieved with classical coherent states (i.e., ideal laser light): (1) Capacity-achieving receiver (measurement) is yet to be determined. (2) Heterodyne detection approaches the ultimate capacity at high mean photon numbers. (3) Photon-counting approaches the ultimate capacity at low mean photon numbers. A number of current technology limits drive the achievable performance of free-space communication links. Approaching fundamental limits in the bandwidth-limited regime: (1) Heterodyne detection with high-order coherent-state modulation approaches ultimate limits. SOA improvements to laser phase noise, adaptive optics systems for atmospheric transmission would help. (2) High-order intensity modulation and photon-counting can approach heterodyne detection within approximately a factor of 2. This may have advantages over coherent detection in the presence of turbulence. Approaching fundamental limits in the photon-limited regime (1) Low-duty cycle binary coherent-state modulation (OOK, PPM) approaches ultimate limits. SOA improvements to laser extinction ratio, receiver dark noise, jitter, and blocking would help. (2) In some link geometries (near field links) number-state transmission could improve over coherent-state transmission

  17. Determining the 95% limit of detection for waterborne pathogen analyses from primary concentration to qPCR.

    PubMed

    Stokdyk, Joel P; Firnstahl, Aaron D; Spencer, Susan K; Burch, Tucker R; Borchardt, Mark A

    2016-06-01

    The limit of detection (LOD) for qPCR-based analyses is not consistently defined or determined in studies on waterborne pathogens. Moreover, the LODs reported often reflect the qPCR assay alone rather than the entire sample process. Our objective was to develop an approach to determine the 95% LOD (lowest concentration at which 95% of positive samples are detected) for the entire process of waterborne pathogen detection. We began by spiking the lowest concentration that was consistently positive at the qPCR step (based on its standard curve) into each procedural step working backwards (i.e., extraction, secondary concentration, primary concentration), which established a concentration that was detectable following losses of the pathogen from processing. Using the fraction of positive replicates (n = 10) at this concentration, we selected and analyzed a second, and then third, concentration. If the fraction of positive replicates equaled 1 or 0 for two concentrations, we selected another. We calculated the LOD using probit analysis. To demonstrate our approach we determined the 95% LOD for Salmonella enterica serovar Typhimurium, adenovirus 41, and vaccine-derived poliovirus Sabin 3, which were 11, 12, and 6 genomic copies (gc) per reaction (rxn), respectively (equivalent to 1.3, 1.5, and 4.0 gc L(-1) assuming the 1500 L tap-water sample volume prescribed in EPA Method 1615). This approach limited the number of analyses required and was amenable to testing multiple genetic targets simultaneously (i.e., spiking a single sample with multiple microorganisms). An LOD determined this way can facilitate study design, guide the number of required technical replicates, aid method evaluation, and inform data interpretation. Published by Elsevier Ltd.

  18. Determining the 95% limit of detection for waterborne pathogen analyses from primary concentration to qPCR

    USGS Publications Warehouse

    Stokdyk, Joel P.; Firnstahl, Aaron; Spencer, Susan K.; Burch, Tucker R; Borchardt, Mark A.

    2016-01-01

    The limit of detection (LOD) for qPCR-based analyses is not consistently defined or determined in studies on waterborne pathogens. Moreover, the LODs reported often reflect the qPCR assay alone rather than the entire sample process. Our objective was to develop an approach to determine the 95% LOD (lowest concentration at which 95% of positive samples are detected) for the entire process of waterborne pathogen detection. We began by spiking the lowest concentration that was consistently positive at the qPCR step (based on its standard curve) into each procedural step working backwards (i.e., extraction, secondary concentration, primary concentration), which established a concentration that was detectable following losses of the pathogen from processing. Using the fraction of positive replicates (n = 10) at this concentration, we selected and analyzed a second, and then third, concentration. If the fraction of positive replicates equaled 1 or 0 for two concentrations, we selected another. We calculated the LOD using probit analysis. To demonstrate our approach we determined the 95% LOD for Salmonella enterica serovar Typhimurium, adenovirus 41, and vaccine-derived poliovirus Sabin 3, which were 11, 12, and 6 genomic copies (gc) per reaction (rxn), respectively (equivalent to 1.3, 1.5, and 4.0 gc L−1 assuming the 1500 L tap-water sample volume prescribed in EPA Method 1615). This approach limited the number of analyses required and was amenable to testing multiple genetic targets simultaneously (i.e., spiking a single sample with multiple microorganisms). An LOD determined this way can facilitate study design, guide the number of required technical replicates, aid method evaluation, and inform data interpretation.

  19. Applicability of solid-phase microextraction combined with gas chromatography atomic emission detection (GC-MIP AED) for the determination of butyltin compounds in sediment samples.

    PubMed

    Carpinteiro, J; Rodríguez, I; Cela, R

    2004-11-01

    The performance of solid-phase microextraction (SPME) applied to the determination of butyltin compounds in sediment samples is systematically evaluated. Matrix effects and influence of blank signals on the detection limits of the method are studied in detail. The interval of linear response is also evaluated in order to assess the applicability of the method to sediments polluted with butyltin compounds over a large range of concentrations. Advantages and drawbacks of including an SPME step, instead of the classic liquid-liquid extraction of the derivatized analytes, in the determination of butyltin compounds in sediment samples are considered in terms of achieved detection limits and experimental effort. Analytes were extracted from the samples by sonication using glacial acetic acid. An aliquot of the centrifuged extract was placed on a vial where compounds were ethylated and concentrated on a PDMS fiber using the headspace mode. Determinations were carried out using GC-MIP AED.

  20. Fully automated analytical procedure for propofol determination by sequential injection technique with spectrophotometric and fluorimetric detections.

    PubMed

    Šrámková, Ivana; Amorim, Célia G; Sklenářová, Hana; Montenegro, Maria C B M; Horstkotte, Burkhard; Araújo, Alberto N; Solich, Petr

    2014-01-01

    In this work, an application of an enzymatic reaction for the determination of the highly hydrophobic drug propofol in emulsion dosage form is presented. Emulsions represent a complex and therefore challenging matrix for analysis. Ethanol was used for breakage of a lipid emulsion, which enabled optical detection. A fully automated method based on Sequential Injection Analysis was developed, allowing propofol determination without the requirement of tedious sample pre-treatment. The method was based on spectrophotometric detection after the enzymatic oxidation catalysed by horseradish peroxidase and subsequent coupling with 4-aminoantipyrine leading to a coloured product with an absorbance maximum at 485 nm. This procedure was compared with a simple fluorimetric method, which was based on the direct selective fluorescence emission of propofol in ethanol at 347 nm. Both methods provide comparable validation parameters with linear working ranges of 0.005-0.100 mg mL(-1) and 0.004-0.243 mg mL(-1) for the spectrophotometric and fluorimetric methods, respectively. The detection and quantitation limits achieved with the spectrophotometric method were 0.0016 and 0.0053 mg mL(-1), respectively. The fluorimetric method provided the detection limit of 0.0013 mg mL(-1) and limit of quantitation of 0.0043 mg mL(-1). The RSD did not exceed 5% and 2% (n=10), correspondingly. A sample throughput of approx. 14 h(-1) for the spectrophotometric and 68 h(-1) for the fluorimetric detection was achieved. Both methods proved to be suitable for the determination of propofol in pharmaceutical formulation with average recovery values of 98.1 and 98.5%. © 2013 Elsevier B.V. All rights reserved.

  1. Lowering detection limits for 1,2,3-trichloropropane in water using solid phase extraction coupled to purge and trap sample introduction in an isotope dilution GC-MS method.

    PubMed

    Liao, Wenta; Ghabour, Miriam; Draper, William M; Chandrasena, Esala

    2016-09-01

    Purge and trap sample introduction (PTI) has been the premier sampling and preconcentration technique for gas chromatographic determination of volatile organic compounds (VOCs) in drinking water for almost 50 years. PTI affords sub parts-per-billion (ppb) detection limits for purgeable VOCs including fixed gases and higher boiling hydrocarbons and halocarbons. In this study the coupling of solid phase extraction (SPE) to PTI was investigated as a means to substantially increase enrichment and lower detection limits for the emerging contaminant, 1,2,3-trichloropropane (TCP). Water samples (500 mL) were dechlorinated, preserved with a biocide, and spiked with the isotope labeled internal standard, d5-TCP. The entire 500 mL sample was extracted with activated carbon or carbon molecular sieve SPE cartridges, and then eluted with dichloromethane -- excess solvent was removed in a nitrogen evaporator and diethylene glycol "keeper" remaining was dispersed in 5 mL of water for PTI GC-MS analysis. The experimental Method Detection Limit (MDL) for TCP was 0.11 ng/L (ppt) and accuracy was 95-103% in sub-ppt determinations. Groundwater samples including impaired California sources and treated water (n = 21) were analyzed with results ranging from below the method reporting limit (0.30 ng/L) to > 250 ng/L. Coupling of SPE with PTI may provide similar reductions in detection limits for other VOCs with appropriate physical-chemical properties. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. Determination of flunixin residues in bovine muscle tissue by liquid chromatography with UV detection.

    PubMed

    Asea, P A; Patterson, J R; Korsrud, G O; Dowling, P M; Boison, J O

    2001-01-01

    A new and sensitive liquid chromatography-ultra violet method with a detection limit of 6 ng/g (ppb) and a limit of quantification of 15 ng/g was developed for the determination of flunixin residues in bovine muscle tissue. Flunixin in homogenized animal tissue was extracted with acetonitrile after enzyme digestion. The tissue digest (extract) was then cleaned up on a solid-phase extraction cartridge and eluted with acidified hexane. After the eluate was evaporated to dryness under nitrogen at 55 degrees C, the residue was reconstituted in 1 mL mobile phase solution and analyzed by reversed-phase gradient chromatography with UV detection at 285 nm. The method was then applied in a survey study of slaughter animals to determine whether flunixin is being used in an off-label manner for veal and beef production in Canada.

  3. Detection limit of a VCO based detection chain dedicated to particles recognition and tracking

    NASA Astrophysics Data System (ADS)

    Coulié, K.; Rahajandraibe, W.; Aziza, H.; Micolau, G.; Vauché, R.

    2018-01-01

    A particle detection chain based on CMOS-SOI VCO circuit is presented. The solution is used for the recognition and the tracking of a given particle at circuit level. TCAD simulation of the detector has been performed on a 3×3 matrix of diodes based detector for particles recognition and tracking. The current response of the detector has been used for a case study in order to determine the ability of the chain to recognize an alpha particle crossing a 3×3 detection cell. The detection limit of the proposed solution is investigated and discussed in this paper.

  4. Exposure to 4,4'-methylenediphenyl diisocyanate (MDI) during moulding of rigid polyurethane foam: determination of airborne MDI and urinary 4,4'-methylenedianiline (MDA).

    PubMed

    Kääriä, K; Hirvonen, A; Norppa, H; Piirilä, P; Vainio, H; Rosenberg, C

    2001-04-01

    Occupational exposure to 4,4'-methylenediphenyl diisocyanate (MDI) was measured during moulding of rigid polyurethane foam. The aim of the study was to find out whether an MDI-derived urinary amine metabolite could be detected in the urine of workers exposed to apparently low levels of MDI. Airborne MDI was sampled on 1-(2-methoxyphenyl)-piperazine (2MP)-impregnated glass fibre filters and determined by high-performance liquid chromatography (HPLC) using ultraviolet (UV) and electrochemical (EC) detection. The limit of detection of MDI was 3 ng ml-1 for a 20 microliters injection. The precision of sample preparation, expressed as relative standard deviation (RSD), was 1.3% with UV detection and 2.1% with EC detection at a concentration of 70 ng MDI ml-1 (n = 6). The 2MP-MDI derivative was stable at +4 degrees C up to eight weeks. The accuracy of the method was validated in an international quality control programme. Workers (n = 57) from three different factories participated in the study. Urinary 4,4'-methylenedianiline (MDA) metabolite was determined after acid hydrolysis as heptafluorobutyric anhydride derivatives by gas chromatography-mass spectrometry using chemical ionisation and monitoring negative ions. The limit of detection in urine was 0.2 nmol l-1. The precision of six analyses for a urine sample spiked to a concentration of 1 nmol l-1 was 29% (RSD). The MDI concentrations were below the limit of detection in most (64%) of the air samples collected in the worker's breathing zone. Still, detectable amounts of MDA were found in 97% of the urine samples. Monitoring of urinary MDA appears to be an appropriate method of assessing MDI exposure in work environments with low or undetectable MDI concentrations in the workplace air.

  5. A multi-residue method for the analysis of pesticides and pesticide degradates in water using HLB solid-phase extraction and gas chromatography-ion trap mass spectrometry

    USGS Publications Warehouse

    Hladik, M.L.; Smalling, K.L.; Kuivila, K.M.

    2008-01-01

    A method was developed for the analysis of over 60 pesticides and degradates in water by HLB solid-phase extraction and gas-chromatography/mass spectrometry. Method recoveries and detection limits were determined using two surface waters with different dissolved organic carbon (DOC) concentrations. In the lower DOC water, recoveries and detection limits were 80%-108% and 1-12 ng/L, respectively. In the higher DOC water, the detection limits were slightly higher (1-15 ng/L). Additionally, surface water samples from four sites were analyzed and 14 pesticides were detected with concentrations ranging from 4 to 1,200 ng/L. ?? 2008 Springer Science+Business Media, LLC.

  6. Using harmonic oscillators to determine the spot size of Hermite-Gaussian laser beams

    NASA Technical Reports Server (NTRS)

    Steely, Sidney L.

    1993-01-01

    The similarity of the functional forms of quantum mechanical harmonic oscillators and the modes of Hermite-Gaussian laser beams is illustrated. This functional similarity provides a direct correlation to investigate the spot size of large-order mode Hermite-Gaussian laser beams. The classical limits of a corresponding two-dimensional harmonic oscillator provide a definition of the spot size of Hermite-Gaussian laser beams. The classical limits of the harmonic oscillator provide integration limits for the photon probability densities of the laser beam modes to determine the fraction of photons detected therein. Mathematica is used to integrate the probability densities for large-order beam modes and to illustrate the functional similarities. The probabilities of detecting photons within the classical limits of Hermite-Gaussian laser beams asymptotically approach unity in the limit of large-order modes, in agreement with the Correspondence Principle. The classical limits for large-order modes include all of the nodes for Hermite Gaussian laser beams; Sturm's theorem provides a direct proof.

  7. The solar-flare infrared continuum - Observational techniques and upper limits

    NASA Technical Reports Server (NTRS)

    Hudson, H. S.

    1975-01-01

    Exploratory observations at 20 microns and 350 microns have determined detection thresholds for solar flares in these wavelengths. In the 20-micron range, solar atmospheric fluctuations (the 'temperature field') set the basic limits on flare detectability at about 5 K; at 350 microns, extinction in the earth's atmosphere provides the basic limitation of about 30 K. These thresholds are low enough for the successful detection of several infrared-emitting components of large flares. The upper limits obtained for subflares indicate that the thickness of the H-alpha flare region does not exceed approximately 10 km. This result confirms the conclusion of Suemoto and Hiei (1959) regarding the small effective thickness of the H-alpha-emitting regions in solar flares.

  8. A Review of Flow Analysis Methods for Determination of Radionuclides in Nuclear Wastes and Nuclear Reactor Coolants

    DOE PAGES

    Trojanowicz, Marek; Kolacinska, Kamila; Grate, Jay W.

    2018-02-13

    Here, the safety and security of nuclear power plant operations depend on the application of the most appropriate techniques and methods of chemical analysis, where modern flow analysis methods prevail. Nevertheless, the current status of the development of these methods is more limited than it might be expected based on their genuine advantages. The main aim of this paper is to review the automated flow analysis procedures developed with various detection methods for the nuclear energy industry. The flow analysis methods for the determination of radionuclides, that have been reported to date, are primarily focused on their environmental applications. Themore » benefits of the application of flow methods in both monitoring of the nuclear wastes and process analysis of the primary circuit coolants of light water nuclear reactors will also be discussed. The application of either continuous flow methods (CFA) or injection methods (FIA, SIA) of the flow analysis with the β–radiometric detection shortens the analysis time and improves the precision of determination due to mechanization of certain time-consuming operations of the sample processing. Compared to the radiometric detection, the mass spectrometry (MS) detection enables one to perform multicomponent analyses as well as the determination of transuranic isotopes with much better limits of detection.« less

  9. A Review of Flow Analysis Methods for Determination of Radionuclides in Nuclear Wastes and Nuclear Reactor Coolants

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Trojanowicz, Marek; Kolacinska, Kamila; Grate, Jay W.

    Here, the safety and security of nuclear power plant operations depend on the application of the most appropriate techniques and methods of chemical analysis, where modern flow analysis methods prevail. Nevertheless, the current status of the development of these methods is more limited than it might be expected based on their genuine advantages. The main aim of this paper is to review the automated flow analysis procedures developed with various detection methods for the nuclear energy industry. The flow analysis methods for the determination of radionuclides, that have been reported to date, are primarily focused on their environmental applications. Themore » benefits of the application of flow methods in both monitoring of the nuclear wastes and process analysis of the primary circuit coolants of light water nuclear reactors will also be discussed. The application of either continuous flow methods (CFA) or injection methods (FIA, SIA) of the flow analysis with the β–radiometric detection shortens the analysis time and improves the precision of determination due to mechanization of certain time-consuming operations of the sample processing. Compared to the radiometric detection, the mass spectrometry (MS) detection enables one to perform multicomponent analyses as well as the determination of transuranic isotopes with much better limits of detection.« less

  10. A review of flow analysis methods for determination of radionuclides in nuclear wastes and nuclear reactor coolants.

    PubMed

    Trojanowicz, Marek; Kołacińska, Kamila; Grate, Jay W

    2018-06-01

    The safety and security of nuclear power plant operations depend on the application of the most appropriate techniques and methods of chemical analysis, where modern flow analysis methods prevail. Nevertheless, the current status of the development of these methods is more limited than it might be expected based on their genuine advantages. The main aim of this paper is to review the automated flow analysis procedures developed with various detection methods for the nuclear energy industry. The flow analysis methods for the determination of radionuclides, that have been reported to date, are primarily focused on their environmental applications. The benefits of the application of flow methods in both monitoring of the nuclear wastes and process analysis of the primary circuit coolants of light water nuclear reactors will also be discussed. The application of either continuous flow methods (CFA) or injection methods (FIA, SIA) of the flow analysis with the β-radiometric detection shortens the analysis time and improves the precision of determination due to mechanization of certain time-consuming operations of the sample processing. Compared to the radiometric detection, the mass spectrometry (MS) detection enables one to perform multicomponent analyses as well as the determination of transuranic isotopes with much better limits of detection. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. Determination of benazolin-ethyl residues in soil and rape seed by SPE clean-up and GC with electron capture detection.

    PubMed

    Liu, Xiaolu; Yang, Tao; Hu, Jiye

    2013-01-01

    A method has been developed and established for residue determination of benazolin-ethyl in soil and rape seed samples by gas chromatography with electron capture detection (GC-ECD). Limits of quantification of the method are 0.005 mg/kg for both soil and rape seed, which are sufficiently below the maximum residue limit, and the limit of detection is 0.0023 ng. The average recoveries of the analyte range from 85.89 to 105.84% with relative standard deviations (coefficient of variation) less than 5.53% at the three spike levels (0.005, 0.1 and 0.5 mg/kg). The half-life of benazolin-ethyl in soil from the experimental field is 4.62 days. The final residues of benazolin-ethyl in soil and rape seed samples are lower than 0.005 mg/kg at harvest time. Direct confirmation of the analyte in real samples is achieved by GC-mass spectrometry. It is demonstrated that the proposed method is simple, rapid and efficient, and reliable to detect benazolin-ethyl residues in soil and rape seed samples.

  12. Sensitive electrochemical sensors for simultaneous determination of ascorbic acid, dopamine, and uric acid based on Au@Pd-reduced graphene oxide nanocomposites.

    PubMed

    Jiang, Jingjing; Du, Xuezhong

    2014-10-07

    Sensitive electrochemical sensors were fabricated with reduced graphene oxide-supported Au@Pd (Au@Pd-RGO) nanocomposites by one-step synthesis for individual and simultaneous determination of ascorbic acid (AA), dopamine (DA), and uric acid (UA) with low detection limits and wide concentration ranges. From the Au@Pd-RGO-modified electrodes, well-separated oxidation peaks and enhanced peak currents of AA, DA, and UA were observed owing to the superior conductivity of RGO and the excellent catalytic activity of Au@Pd nanoparticles. For individual detection, the linear responses of AA, DA, and UA were in the concentration ranges of 0.1-1000, 0.01-100, and 0.02-500 μM with detection limits of 0.02, 0.002, and 0.005 μM (S/N = 3), respectively. For simultaneous detection by synchronous change of the concentrations of AA, DA, and UA, the linear response ranges were 1-800, 0.1-100, and 0.1-350 μM with detection limits of 0.28, 0.024, and 0.02 μM (S/N = 3), respectively. The fabricated sensors were further applied to the detection of AA, DA, and UA in urine samples. The Au@Pd-RGO nanocomposites have promising applications in highly sensitive and selective electrochemical sensing.

  13. Spectrophotometric and fluorimetric determination of diazepam, bromazepam and clonazepam in pharmaceutical and urine samples

    NASA Astrophysics Data System (ADS)

    Salem, A. A.; Barsoum, B. N.; Izake, E. L.

    2004-03-01

    New spectrophotometric and fluorimetric methods have been developed to determine diazepam, bromazepam and clonazepam (1,4-benzodiazepines) in pure forms, pharmaceutical preparations and biological fluid. The new methods are based on measuring absorption or emission spectra in methanolic potassium hydroxide solution. Fluorimetric methods have proved selective with low detection limits, whereas photometric methods showed relatively high detection limits. Successive applications of developed methods for drugs determination in pharmaceutical preparations and urine samples were performed. Photometric methods gave linear calibration graphs in the ranges of 2.85-28.5, 0.316-3.16, and 0.316-3.16 μg ml -1 with detection limits of 1.27, 0.08 and 0.13 μg ml -1 for diazepam, bromazepam and clonazepam, respectively. Corresponding average errors of 2.60, 5.26 and 3.93 and relative standard deviations (R.S.D.s) of 2.79, 2.12 and 2.83, respectively, were obtained. Fluorimetric methods gave linear calibration graphs in the ranges of 0.03-0.34, 0.03-0.32 and 0.03-0.38 μg ml -1 with detection limits of 7.13, 5.67 and 16.47 ng ml -1 for diazepam, bromazepam and clonazepam, respectively. Corresponding average errors of 0.29, 4.33 and 5.42 and R.S.D.s of 1.27, 1.96 and 1.14 were obtained, respectively. Statistical Students t-test and F-test have been used and satisfactory results were obtained.

  14. Pesticides in near-surface aquifers: An assessment using highly sensitive analytical methods and tritium

    USGS Publications Warehouse

    Kolpin, D.W.; Goolsby, D.A.; Thurman, E.M.

    1995-01-01

    In 1992, the U.S. Geological Survey (USGS) determined the distribution of pesticides in near-surface aquifers of the midwestern USA to be much more widespread than originally determined during a 1991 USGS study. The frequency of pesticide detection increased from 28.4% during the 1991 study to 59.0% during the 1992 study. This increase in pesticide detection was primarily the result of a more sensitive analytical method that used reporting limits as much as 20 times lower than previously available and a threefold increase in the number of pesticide metabolites analyzed. No pesticide concentrations exceeded the U.S. Environmental Protection Agency's (USEPAs) maximum contaminant levels or health advisory levels for drinking water. However, five of the six most frequently detected compounds during 1992 were pesticide metabolites that currently do not have drinking water standards determined. The frequent presence of pesticide metabolites for this study documents the importance of obtaining information on these compounds to understand the fate and transport of pesticides in the hydrologic system. It appears that the 56 parent compounds analyzed follow similar pathways through the hydrologic system as atrazine. When atrazine was detected by routine or sensitive analytical methods, there was an increased likelihood of detecting additional parent compounds. As expected, the frequency of pesticide detection was highly dependent on the analytical reporting limit. The number of atrazine detections more than doubled as the reporting limit decreased from 0.10 to 0.01 µg/L. The 1992 data provided no indication that the frequency of pesticide detection would level off as improved analytical methods provide concentrations below 0.003 µg/L. A relation was determined between groundwater age and the frequency of pesticide detection, with 15.8% of the samples composed of pre-1953 water and 70.3% of the samples of post-1953 water having a detection of at least one pesticide or metabolite. Pre-1953 water is less likely to contain pesticides because it tends to predate the use of pesticides to increase crop production in the Midwest. Pre-1953 water was more likely to occur in the near-surface bedrock aquifers (50.0%) than in the near-surface unconsolidated aquifers (9.1%) sampled.

  15. [Determination of aluminium in flour foods with photometric method].

    PubMed

    Ma, Lan; Zhao, Xin; Zhou, Shuang; Yang, Dajin

    2012-05-01

    To establish a determination method for aluminium in flour foods with photometric method. After samples being treated with microwave digestion and wet digestion, aluminium in staple flour foods was determined by photometric method. There was a good linearity of the result in the range of 0.25 - 5.0 microg/ml aluminium, r = 0.9998; limit of detection (LOD) : 2.3 ng/ml; limit of quantitation (LOQ) : 7 ng/ml. This method of determining aluminium in flour foods is simple, rapid and reliable.

  16. A Liquid Chromatography – Tandem Mass Spectrometry Approach for the Identification of Mebendazole Residue in Pork, Chicken, and Horse

    PubMed Central

    Lee, Ji Sun; Cho, Soo Hee; Lim, Chae Mi; Chang, Moon Ik; Joo, Hyun Jin; Park, Hyun Jin

    2017-01-01

    A confirmatory and quantitative method of liquid chromatography-tandem mass spectrometry (LC-MS/MS) for the determination of mebendazole and its hydrolyzed and reduced metabolites in pork, chicken, and horse muscles was developed and validated in this study. Anthelmintic compounds were extracted with ethyl acetate after sample mixture was made alkaline followed by liquid chromatographic separation using a reversed phase C18 column. Gradient elution was performed with a mobile phase consisting of water containing 10 mM ammonium formate and methanol. This confirmatory method was validated according to EU requirements. Evaluated validation parameters included specificity, accuracy, precision (repeatability and within-laboratory reproducibility), analytical limits (decision limit and detection limit), and applicability. Most parameters were proved to be conforming to the EU requirements. The decision limit (CCα) and detection capability (CCβ) for all analytes ranged from 15.84 to 17.96 μgkg-1. The limit of detection (LOD) and the limit of quantification (LOQ) for all analytes were 0.07 μgkg-1 and 0.2 μgkg-1, respectively. The developed method was successfully applied to monitoring samples collected from the markets in major cities and proven great potential to be used as a regulatory tool to determine mebendazole residues in animal based foods. PMID:28085912

  17. [Investigation of concentration levels of chromium(VI) in bottled mineral and spring waters by high performance ion chromatography technique with application of postcolumn reaction with 1,5-diphenylcarbazide and VIS detection].

    PubMed

    Swiecicka, Dorota; Garboś, Sławomir

    2008-01-01

    The aim of this work was optimization and validation of the method of determination of Cr(VI) existing in the form of chromate(VI) in mineral and spring waters by High Performance Ion Chromatography (HPIC) technique with application of postcolumn reaction with 1,5-diphenylcarbazide and VIS detection. Optimization of the method performed with the use of initial apparatus parameters and chromatographic conditions from the Method 218.6 allowed to lowering detection limit for Cr(VI) from 400 ng/l to 2 ng/l. Thanks to very low detection limit achieved it was possible to determine of Cr(VI) concentrations in 25 mineral and spring waters presented at Polish market. In the cases of four mineral and spring waters analyzed, determined Cr(VI) concentrations were below of quantification limit (< 4 ng/l) but simultaneously in another mineral and spring waters the concentrations of chromium(VI) were determined in the range of 5.6 - 1281 ng/l. The fact of existence of different Cr(VI) concentrations in investigated waters could be connected with secondary contamination of mineral and spring waters by chromium coming from metal installations and fittings. One should be underlined that even the highest determined concentration level of chromium(VI) was below of the maximum admissible concentration of total chromium presented in Polish Decree of Minister of Health from April 29th 2004. Therefore after taking into account determined in this work concentration of Cr(VI), the consumption of all waters analyzed in this study does not lead to essential human health risk.

  18. [Standard addition determination of impurities in Na2CrO4 by ICP-AES].

    PubMed

    Wang, Li-ping; Feng, Hai-tao; Dong, Ya-ping; Peng, Jiao-yu; Li, Wu; Shi, Hai-qin; Wang, Yong

    2015-02-01

    Coupled plasma atomic emission spectrometry (ICP-AES) was used to determine the trace impurities of Ca, Mg, Al, Fe and Si in industrial sodium chromate. Wavelengths of 167.079, 393.366, 259.940, 279.533 and 251.611 nm were selected as analytical lines for the determination of Al, Ca, Fe, Mg and Si, respectively. The analytical errors can be eliminated by adjusting the determined solution with high pure hydrochloric acid. Standard addition method was used to eliminate matrix effects. The linear correlation, detection limit, precision and recovery for the concerned trace impurities have been examined. The effect of standard addition method on the accuracy for the determination under the selected analytical lines has been studied in detail. The results show that the linear correlations of standard curves were very good (R2 = 0.9988 to 0.9996) under the determined conditions. Detection limits of these trace impurities were in the range of 0.0134 to 0.0280 mg x L(-1). Sample recoveries were within 97.30% to 107.50%, and relative standard deviations were lower than 5.86% for eleven repeated determinations. The detection limits and accuracies established by the experiment can meet the analytical requirements and the analytic procedure was used to determine trace impurities in sodium chromate by ion membrane electrolysis technique successfully. Due to sodium chromate can be changed into sodium dichromate and chromic acid by adding acids, the established method can be further used to monitor trace impurities in these compounds or other hexavalent chromium compounds.

  19. Determination of nitrobenzene in wastewater using a hanging mercury drop electrode.

    PubMed

    Liang, Shu-Xuan; Zhang, Huan-Kun; Lu, Da

    2007-06-01

    The determination of trace amount nitrobenzene in wastewater on a hanging mercury drop electrode was studied. The determination conditions of pH, supporting electrolyte, accumulation potential, accumulation time, and voltammetric response were optimized. The sharp peak of the nitrobenzene was appeared at 0.05 V. The peak electric current was proportional to the concentration of nitrobenzene in the range of 1.47 x 10(-5) approximately 1.0 x 10(-3) mol/l with relative standard deviations of 3.99 approximately 8.94%. The detection limit of the nitrobenzene in water was 5 x 10(-6) mol/l. The proposed method offered low limit of determination, easy operation, the use of simple instrumentation, high sensitivity and good reproducibility. It was applied to the determination of nitrobenzene in wastewater with an average recovery of 94.0% approximately 105%. The proposed method provided fast, sensitive and sometimes real time detection of nitrobenzene.

  20. Detection of alprazolam with a lab on paper economical device integrated with urchin like Ag@ Pd shell nano-hybrids.

    PubMed

    Narang, Jagriti; Malhotra, Nitesh; Singhal, Chaitali; Mathur, Ashish; Pn, Anoop Krishna; Pundir, C S

    2017-11-01

    We present results of the studies relating to fabrication of a microfluidic biosensor chip based on urchin like Ag@ Pd shell nano-hybrids that is capable of sensing alprazolam through electrochemical detection. Using this chip we demonstrate, with high reliability and in a time efficient manner, the detection of alprazolam present in buffer solutions at clinically relevant concentrations. Methylene blue (MB) was also doped as redox transition substance for sensing alprazolam. Nano-hybrids modified EμPAD showed wide linear range 1-300ng/ml and low detection limit of 0.025ng/l. Low detection limit can further enhance its suitability for forensic application. Nano-hybrids modified EμPAD was also employed for determination of drug in real samples such as human urine. Reported facile lab paper approach integrated with urchin like Ag@ Pd shell nano-hybrids could be well applied for the determination of serum metabolites. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Quantitative determination of trigonelline in mouse serum by means of hydrophilic interaction liquid chromatography-MS/MS analysis: Application to a pharmacokinetic study.

    PubMed

    Szczesny, Damian; Bartosińska, Ewa; Jacyna, Julia; Patejko, Małgorzata; Siluk, Danuta; Kaliszan, Roman

    2018-02-01

    Trigonelline is a pyridine alkaloid found in fenugreek seeds and coffee beans. Most of the previous studies are concerned with the quantification of trigonelline along with other constituents in coffee herbs or beverages. Only a few have focused on its determination in animal or human tissues by applying different modes of HPLC with UV or MS detection. The aim of the study was to develop and validate a fast and simple method for trigonelline determination in serum by the use of hydrophilic interaction liquid chromatography (HILIC) with ESI-MS/MS detection. Separation of trigonelline was achieved on a Kinetex HILIC column operated at 35°C with acetonitrile-ammonium formate (10 mm, pH = 3) buffer mixture (55:45, v/v) as the mobile phase. The developed method was successfully applied to determine trigonelline concentration in mouse serum after intravenous administration of 10 mg/kg. The developed assay is sensitive (limit of detection = 1.5 ng/mL, limit of quantification = 5.0 ng/mL) and linear in a concentration range from 5.0 to 250.0 ng/mL. Sample preparation is limited to deproteinization, centrifugation and filtration. The application of the HILIC mode of chromatography with MS detection and selection of deuterated trigonelline as internal standard allowed a rapid and precise method of trigonelline quantification to be to developed. Copyright © 2017 John Wiley & Sons, Ltd.

  2. Electrochemical Study of Carbon Nanotubes/Nanohybrids for Determination of Metal Species Cu2+ and Pb2+ in Water Samples

    PubMed Central

    Oliveira Silva, Andréa Claudia; de Oliveira, Luis Carlos Ferreira; Vieira Delfino, Angladis; Meneghetti, Mario Roberto

    2016-01-01

    The use of nanomaterials, such as nanoparticles and nanotubes, for electrochemical detection of metal species has been investigated as a way of modifying electrodes by electrochemical stripping analysis. The present study develops a new methodology based on a comparative study of nanoparticles and nanotubes with differential pulse anodic stripping voltammetry (DPASV) and examines the simultaneous determination of copper and lead. The glassy carbon electrode modified by gold nanoparticles demonstrated increased sensitivity and decreased detection limits, among other improvements in analytical performance data. Under optimized conditions (deposition potential −0.8 V versus Ag/AgCl; deposition time, 300 s; resting time, 10 s; pulse amplitude, 50 mV; and voltage step height, 4 mV), the detection limits were 0.2279 and 0.3321 ppb, respectively, for determination of Pb2+ and Cu2+. The effects of cations and anions on the simultaneous determination of metal ions do not exhibit significant interference, thereby demonstrating the selectivity of the electrode for simultaneous determination of Pb2+ and Cu2+. The same method was also used to determine Cu2+ in water samples. PMID:27882263

  3. PdNi- and Pd-coated electrodes prepared by electrodeposition from ionic liquid for nonenzymatic electrochemical determination of ethanol and glucose in alkaline media.

    PubMed

    Huang, Hsin-Yi; Chen, Po-Yu

    2010-12-15

    Nonenzymatic electrochemical determination of ethanol and glucose was respectively achieved using PdNi- and Pd-coated electrodes prepared by electrodeposition from the novel metal-free ionic liquid (IL); N-butyl-N-methylpyrrolidinium dicyanamide (BMP-DCA). BMP-DCA provided an excellent environment and wide cathodic limit for electrodeposition of metals and alloys because many metal chlorides could dissolve in this IL where the reduction potentials of Pd(II) and Ni(II) indeed overlapped, leading to the convenience of potentiostatic codeposition. In aqueous solutions, the reduction potentials of Pd(II) and Ni(II) are considerably separated. The bimetallic PdNi coatings with atomic ratios of ∼ 80/20 showed the highest current for ethanol oxidation reaction (EOR). Ethanol was detected by either cyclic voltammetry (CV) or hydrodynamic amperometry (HA). Using CV, the dependence of EOR peak current on concentration was linear from 4.92 to 962 μM with a detection limit of 2.26 μM (σ=3), and a linearity was observed from 4.92 to 988 μM using HA (detection limit 0.83 μM (σ=3)). The Pd-coated electrodes prepared by electrodeposition from BMP-DCA showed electrocatalytic activity to glucose oxidation and CV, HA, and square-wave voltammetry (SWV) were employed to determine glucose. SWV showed the best sensitivity and linearity was observed from 2.86 μM to 107 μM, and from 2.99 mM to 10.88 mM with detection limits of 0.78 μM and 25.9 μM (σ=3), respectively. For glucose detection, the interference produced from ascorbic acid, uric acid, and acetaminophen was significantly suppressed, compared with a regular Pt disk electrode. Copyright © 2010 Elsevier B.V. All rights reserved.

  4. Preliminary evaluation of monolithic column high-performance liquid chromatography with tris(2,2'-bipyridyl)ruthenium(II) chemiluminescence detection for the determination of quetiapine in human body fluids.

    PubMed

    Bellomarino, Sara A; Brown, Allyson J; Conlan, Xavier A; Barnett, Neil W

    2009-03-15

    High-performance liquid chromatography (HPLC) with tris(2,2'-bipyridyl)ruthenium(II) chemiluminescence detection methodology is reported for the determination of the atypical antipsychotic drug quetiapine and the observation of its major active and inactive metabolites in human urine and serum. The method uses a monolithic chromatographic column allowing high flow rates of 3 mLmin(-1) enabling rapid quantification. Flow injection analysis (FIA) with tris(2,2'-bipyridyl)ruthenium(II) chemiluminescence detection and HPLC time of flight mass spectrometry (TOF-MS) were used for the determination of quetiapine in a pharmaceutical preparation to establish its suitability as a calibration standard. The limit of detection achieved with FIA was 2 x 10(-11) molL(-1) in simple aqueous solution. The limits of detection achieved with HPLC were 7 x 10(-8) and 2 x 10(-10) molL(-1) in urine and serum, respectively. The calibration range for FIA was between 5 x 10(-9) and 1 x 10(-6) molL(-1). The calibration ranges for HPLC were between 1 x 10(-7)-1 x 10(-4) and 1 x 10(-8)-1 x 10(-4) molL(-1) in urine and serum, respectively. The quetiapine concentrations in patient samples were found to be 3 x 10(-6) molL(-1) in urine and 7 x 10(-7) molL(-1) in serum. Without the need for preconcentration, the HPLC detection limits compared favourably with those in previously published methodologies. The metabolites were identified using HPLC-TOF-MS.

  5. Determination of trace metals in spirits by total reflection X-ray fluorescence spectrometry

    NASA Astrophysics Data System (ADS)

    Siviero, G.; Cinosi, A.; Monticelli, D.; Seralessandri, L.

    2018-06-01

    Eight spirituous samples were analyzed for trace metal content with Horizon Total Reflection X-Ray Fluorescence (TXRF) Spectrometer. The expected single metal amount is at the ng/g level in a mixed aqueous/organic matrix, thus requiring a sample preparation method capable of achieving suitable limits of detection. On-site enrichment and Atmospheric Pressure-Vapor Phase Decomposition allowed to detect Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Sr and Pb with detection limits ranging from 0.1 ng/g to 4.6 ng/g. These results highlight how the synergy between instrument and sample preparation strategy may foster the use of TXRF as a fast and reliable technique for the determination of trace elements in spirituous samples, either for quality control or risk assessment purposes.

  6. Carbohydrate and alditol analysis by high-performance anion-exchange chromatography coupled with electrochemical detection at a cobalt-modified electrode.

    PubMed

    Casella, Innocenzo G; Contursi, Michela

    2003-07-01

    A cobalt oxyhydroxide film dispersed on a carbon electrode surface was characterized and proposed as an amperometric sensor for determination of alditols and carbohydrates in flowing streams. Complex mixtures of carbohydrates were separated by anion-exchange chromatography using a moderately alkaline solution as mobile phase. The cobalt modified electrode (GC-Co) was employed under a constant applied potential of 0.5 V (vs Ag/AgCl). Under these experimental conditions the detection limits (S/N=3) for all analyzed electroactive molecules ranged between 0.3 micromol L(-1) and 1.5 micromol L(-1) and the dynamic linear ranges spanned generally three orders of magnitude above the relevant detection limits. Analytical determinations of carbohydrates and alditols in red and white wines, are reported.

  7. Determination of MDMA, MDEA and MDA in urine by high performance liquid chromatography with fluorescence detection.

    PubMed

    da Costa, José Luiz; da Matta Chasin, Alice Aparecida

    2004-11-05

    This paper describes the development and validation of analytical methodology for the determination of the use of MDMA, MDEA and MDA in urine. After a simple liquid extraction, the analyses were carried out on a high performance liquid chromatography (HPLC) in an octadecyl column, with fluorescence detection. The mobile phase using a sodium dodecyl sulfate ion-pairing reagent allows good separation and efficiency. The method showed good linearity and precision. Recovery was between 85 and 102% and detection limits were 10, 15 and 20 ng/ml for MDA, MDMA and MDEA, respectively. No interfering substances were detected with fluorescence detection.

  8. Censoring approach to the detection limits in X-ray fluorescence analysis

    NASA Astrophysics Data System (ADS)

    Pajek, M.; Kubala-Kukuś, A.

    2004-10-01

    We demonstrate that the effect of detection limits in the X-ray fluorescence analysis (XRF), which limits the determination of very low concentrations of trace elements and results in appearance of the so-called "nondetects", can be accounted for using the statistical concept of censoring. More precisely, the results of such measurements can be viewed as the left random censored data, which can further be analyzed using the Kaplan-Meier method correcting the data for the presence of nondetects. Using this approach, the results of measured, detection limit censored concentrations can be interpreted in a nonparametric manner including the correction for the nondetects, i.e. the measurements in which the concentrations were found to be below the actual detection limits. Moreover, using the Monte Carlo simulation technique we show that by using the Kaplan-Meier approach the corrected mean concentrations for a population of the samples can be estimated within a few percent uncertainties with respect of the simulated, uncensored data. This practically means that the final uncertainties of estimated mean values are limited in fact by the number of studied samples and not by the correction procedure itself. The discussed random-left censoring approach was applied to analyze the XRF detection-limit-censored concentration measurements of trace elements in biomedical samples.

  9. Simultaneous determination of flavonoids, isochlorogenic acids and triterpenoids in Ilex hainanensis Using high performance liquid chromatography coupled with diode array and evaporative light scattering detection.

    PubMed

    Peng, Bo; Qiao, Chun-Feng; Zhao, Jing; Huang, Wei-Hua; Hu, De-Jun; Liu, Hua-Gang; Li, Shao-Ping

    2013-03-04

    A high performance liquid chromatography coupled with diode array and evaporative light scattering detection (HPLC-DAD-ELSD) method for simultaneous determination of eight major bioactive compounds including two flavonoids (rutin and eriodictyol-7-O-β-D-glucopyranoside), two isochlorogenic acids (isochlorogenic acid A and isochlorogenic acid C) and four triterpenoids (ilexhainanoside D, ilexsaponin A1, ilexgenin A and ursolic acid) in Ilex hainanensis has been developed for the first time. The 283 nm wavelength was chosen for determination of two flavonoids and two isochlorogenic acids. ELSD was applied to determine four triterpenoids. The analysis was performed on an Agilent Zorbax SB-C18 column (250 × 4.6 mm i.d., 5 µm) with gradient elution of 0.2% formic acid in water and acetonitrile. The method was validated for linearity, limit of detection, limit of quantification, precision, repeatability and accuracy. The proposed method has been successfully applied for simultaneous quantification of the analytes in four samples of Ilex hainanensis, which is helpful for quality control of this plant.

  10. Diode laser detection of greenhouse gases in the near-infrared region by wavelength modulation spectroscopy: pressure dependence of the detection sensitivity.

    PubMed

    Asakawa, Takashi; Kanno, Nozomu; Tonokura, Kenichi

    2010-01-01

    We have investigated the pressure dependence of the detection sensitivity of CO(2), N(2)O and CH(4) using wavelength modulation spectroscopy (WMS) with distributed feed-back diode lasers in the near infrared region. The spectral line shapes and the background noise of the second harmonics (2f) detection of the WMS were analyzed theoretically. We determined the optimum pressure conditions in the detection of CO(2), N(2)O and CH(4), by taking into consideration the background noise in the WMS. At the optimum total pressure for the detection of CO(2), N(2)O and CH(4), the limits of detection in the present system were determined.

  11. Trace Level Determination of Polyether Ionophores in Feed

    PubMed Central

    Rokka, Mervi; Jestoi, Marika; Peltonen, Kimmo

    2013-01-01

    A liquid chromatography-mass spectrometric method was developed and validated to determine six polyether ionophores (lasalocid sodium, monensin sodium, salinomycin sodium, narasin, maduramicin ammonium alpha, and semduramicin sodium) in feed samples. The method developed was very straightforward, involving extraction with 84% acetonitrile of the coccidiostats from the feed samples and filtration of the raw extract prior to chromatographic analysis. Method validation included the determination of selectivity, linearity, specificity, repeatability, the limit of detection, limit of quantification, decision limit (CCα), detection capability (CCβ), and recovery. Feed samples from the Finnish national feed control programme and suspected carry-over samples from a feed manufacturer were analysed in parallel with an existing liquid chromatography method coupled with ultraviolet detection. All feed control samples were negative in LC-UV, but with the developed MS method, monensin, salinomycin, and narasin were detected at concentrations of <0.025–0.73 mg/kg, <0.025–0.027 mg/kg, and <0.025–1.6 mg/kg, respectively. In suspected carry-over samples after an output of 2.0 tonnes of unmedicated feed in the pelletizer line, the concentrations of monensin, salinomycin, and narasin varied from undetected to 16 mg/kg. In the mixer line, after 3.2 tonnes of unmedicated feed output, the concentrations of monensin, salinomycin, and narasin varied from undetected to 2.4 mg/kg. PMID:23484082

  12. Flower-like ZnO decorated polyaniline/reduced graphene oxide nanocomposites for simultaneous determination of dopamine and uric acid.

    PubMed

    Ghanbari, Kh; Moloudi, M

    2016-11-01

    A novel sensor was fabricated by electrochemical deposition of ZnO flower-like/polyaniline nanofiber/reduced graphene oxide nanocomposite (ZnO/PANI/RGO) on glassy carbon electrode (GCE) for direct detection of dopamine (DA) and uric acid (UA) in the presence of fixed concentration of ascorbic acid (AA). Surface morphology and characterization of the modified electrodes were confirmed by field emission scanning microscopy (FE-SEM), X-ray diffraction (XRD), Raman and FT-IR spectroscopies. For individual detection, the linear responses were in the two concentration ranges of 0.001-1 μM and 1-1000 μM with detection limit 0.8 nM (S/N = 3) for DA, and also 0.1-100 μM and 100-1000 μM with detection limit 0.042 μM (S/N = 3) for UA. Simultaneous determination of these species in their mixture solution showed the linear responses in the two concentration ranges of 0.1-90 μM and 90-1000 μM with detection limit 0.017 μM (S/N = 3) for DA and also showed two linear range of 0.5-90 μM and 100-1000 μM with detection limit 0.12 μM (S/N = 3) for UA, with coexistence of 1000 μM AA. The applicability of sensor for the analysis of DA, and UA in dopamine injection solution, human serum and human urine samples was successfully demonstrated. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Methods for threshold determination in multiplexed assays

    DOEpatents

    Tammero, Lance F. Bentley; Dzenitis, John M; Hindson, Benjamin J

    2014-06-24

    Methods for determination of threshold values of signatures comprised in an assay are described. Each signature enables detection of a target. The methods determine a probability density function of negative samples and a corresponding false positive rate curve. A false positive criterion is established and a threshold for that signature is determined as a point at which the false positive rate curve intersects the false positive criterion. A method for quantitative analysis and interpretation of assay results together with a method for determination of a desired limit of detection of a signature in an assay are also described.

  14. Determination of tylosin and tilmicosin residues in animal tissues by reversed-phase liquid chromatography.

    PubMed

    Chan, W; Gerhardt, G C; Salisbury, C D

    1994-01-01

    A method for the simultaneous determination of tylosin and tilmicosin residues in animal tissues is reported. Solid-phase extraction columns are used to isolate the drugs from tissue extracts. Determination is accomplished by reversed-phase liquid chromatography with UV detection at 287 nm. Mean recoveries from spiked tissues were 79.9% (coefficient of variation [CV], 8.1%) for tylosin and 92.6% (CV, 8.7%) for tilmicosin. Detection limits for tylosin and tilmicosin were 0.020 and 0.010 ppm, respectively.

  15. Fast methods for analysis of neurotransmitters from single cell and monitoring their releases in central nervous system by capillary electrophoresis, fluorescence microscopy and luminescence imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Ziqiang

    1999-12-10

    Fast methods for separation and detection of important neurotransmitters and the releases in central nervous system (CNS) were developed. Enzyme based immunoassay combined with capillary electrophoresis was used to analyze the contents of amino acid neurotransmitters from single neuron cells. The release of amino acid neurotransmitters from neuron cultures was monitored by laser induced fluorescence imaging method. The release and signal transduction of adenosine triphosphate (ATP) in CNS was studied with sensitive luminescence imaging method. A new dual-enzyme on-column reaction method combined with capillary electrophoresis has been developed for determining the glutamate content in single cells. Detection was based onmore » monitoring the laser-induced fluorescence of the reaction product NADH, and the measured fluorescence intensity was related to the concentration of glutamate in each cell. The detection limit of glutamate is down to 10 -8 M level, which is 1 order of magnitude lower than the previously reported detection limit based on similar detection methods. The mass detection limit of a few attomoles is far superior to that of any other reports. Selectivity for glutamate is excellent over most of amino acids. The glutamate content in single human erythrocyte and baby rat brain neurons were determined with this method and results agreed well with literature values.« less

  16. Determination of seven flavonoids in Ixeridium gracile (DC.) Shih by high-performance liquid chromatography.

    PubMed

    Chen, Juan; Ma, Xue-Mei; Shi, Yan-Ping

    2009-01-01

    A high-performance liquid chromatographic technique coupled with photodiode array detection was proposed for the simultaneous determination of 7 flavonoids, i.e., quercetin, kaempferol, 7-hydroxyflavanone, 7-methoxyflavanone, 2',4'-dihydroxychalcone, 2',4'-dihydroxydihydrochalcone, and 7,2'-dihydroxy-3', 4'-dimethoxyisoflavane, in extracts of the plant Ixeridium gracile. Optimum separation was obtained by using a reversed-phase C18 method. Because of the different UV characteristics of these components, 5 detection wavelengths were used for the quantitative analysis. All of the flavonoids showed good linearity (r > 0.9999). The limit of detection and limit of quantitation values for the analytes ranged from 0.06 to 0.46 microg/mL and from 0.18 to 1.48 microg/mL, respectively. The method was validated by evaluating repeatability, precision, stability, and accuracy. Five different extraction and purification procedures were investigated for preparation of the sample solution. The optimized method was applied to the determination of flavonoids in I. gracile and was found to be efficient.

  17. Detection limits for nanoparticles in solution with classical turbidity spectra

    NASA Astrophysics Data System (ADS)

    Le Blevennec, G.

    2013-09-01

    Detection of nanoparticles in solution is required to manage safety and environmental problems. Spectral transmission turbidity method has now been known for a long time. It is derived from the Mie Theory and can be applied to any number of spheres, randomly distributed and separated by large distance compared to wavelength. Here, we describe a method for determination of size, distribution and concentration of nanoparticles in solution using UV-Vis transmission measurements. The method combines Mie and Beer Lambert computation integrated in a best fit approximation. In a first step, a validation of the approach is completed on silver nanoparticles solution. Verification of results is realized with Transmission Electronic Microscopy measurements for size distribution and an Inductively Coupled Plasma Mass Spectrometry for concentration. In view of the good agreement obtained, a second step of work focuses on how to manage the concentration to be the most accurate on the size distribution. Those efficient conditions are determined by simple computation. As we are dealing with nanoparticles, one of the key points is to know what the size limits reachable are with that kind of approach based on classical electromagnetism. In taking into account the transmission spectrometer accuracy limit we determine for several types of materials, metals, dielectrics, semiconductors the particle size limit detectable by such a turbidity method. These surprising results are situated at the quantum physics frontier.

  18. [Determination of lead in edible salt with solid-phase extraction and GFAAS].

    PubMed

    Zhao, Xin; Zhou, Shuang; Ma, Lan; Yang, Dajin

    2013-01-01

    Establishing a method for determination of lead in salt with solid-phase extraction and GFAAS. Salt sample was diluted to a certain volume directly with ammonium acetate, then the sample solution was filtered through the solid phase extraction column which has been pre-activated. Lead ions were retained, and the sodium chloride matrix was removed. After elution, the collected lead ions was determined by graphite furnace atomic absorption spectrometry in 257.4 nm. This method can be used effectively to wipe off the sodium chloride in matrix. The limit of detection was 0.7 microg/kg and the limit of quantification was 2 microg/kg. Solid phase extraction technique can be used effectively to reduce the interference in matrix and improves the accuracy and reproducibility of detection.

  19. Photoelectrochemical detection of benzaldehyde in foodstuffs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    LaCourse, W.R.; Krull, I.S.

    Photoelectrochemical detection (PED) coupled with high performance liquid chromatography was used to quantitatively determine benzaldehyde in extracts, beverages, and foodstuffs. Photoelectrochemical detection is responsive to alkyl and aryl ketones and aldehydes and offers the advantages of 2-3 orders of magnitude linearity, 5-1-ng limits of detection, and a high degree of selectivity without chemical derivatization. This is the first application of the PED to sample analysis.

  20. Sensitive high-performance liquid chromatographic method with fluorometric detection for the simultaneous determination of gabapentin and vigabatrin in serum and urine.

    PubMed

    Wad, N; Krämer, G

    1998-01-23

    Serum concentrations of the antiepileptic drug gabapentin (GBP) are usually determined by high-performance liquid chromatography (HPLC) using UV photometric detection after pre-column derivatization with 2,4,6-trinitrobenzenesulphonic acid. Vigabatrin levels in serum are determined by HPLC using fluorescence detection. Like vigabatrin (VGB), gabapentin has also a primary amine group that easily reacts with o-phthaldialdehyde reagent and produces a fluorescing substance. By the use of fluorometric detection, GBP can be determined more simply, sensitively and simultaneously with VGB. The day-to-day coefficient of variation for the determination of GBP in a pooled serum was 4.0% (n=17; serum concentration, 13.8 micromol/l) and forVGB was 3.1% (n=21; serum concentration, 26.4 micromol/l). The lower limit of detection is 0.5 micromol/l for both drugs and the method is linear up to 500 micromol/l for GBP and 1300 micromol/l for VGB.

  1. High-sensitivity detection of cardiac troponin I with UV LED excitation for use in point-of-care immunoassay.

    PubMed

    Rodenko, Olga; Eriksson, Susann; Tidemand-Lichtenberg, Peter; Troldborg, Carl Peder; Fodgaard, Henrik; van Os, Sylvana; Pedersen, Christian

    2017-08-01

    High-sensitivity cardiac troponin assay development enables determination of biological variation in healthy populations, more accurate interpretation of clinical results and points towards earlier diagnosis and rule-out of acute myocardial infarction. In this paper, we report on preliminary tests of an immunoassay analyzer employing an optimized LED excitation to measure on a standard troponin I and a novel research high-sensitivity troponin I assay. The limit of detection is improved by factor of 5 for standard troponin I and by factor of 3 for a research high-sensitivity troponin I assay, compared to the flash lamp excitation. The obtained limit of detection was 0.22 ng/L measured on plasma with the research high-sensitivity troponin I assay and 1.9 ng/L measured on tris-saline-azide buffer containing bovine serum albumin with the standard troponin I assay. We discuss the optimization of time-resolved detection of lanthanide fluorescence based on the time constants of the system and analyze the background and noise sources in a heterogeneous fluoroimmunoassay. We determine the limiting factors and their impact on the measurement performance. The suggested model can be generally applied to fluoroimmunoassays employing the dry-cup concept.

  2. Trueness, Precision, and Detectability for Sampling and Analysis of Organic Species in Airborne Particulate Matter

    EPA Science Inventory

    Recovery. precision, limits of detection and quantitation, blank levels, calibration linearity, and agreement with certified reference materials were determined for two classes of organic components of airborne particulate matter, polycyclic aromatic hydrocarbons and hopanes usin...

  3. Methods of analysis by the U.S. Geological Survey National Water Quality Laboratory; determination of chromium in water by graphite furnace atomic absorption spectrophotometry

    USGS Publications Warehouse

    McLain, B.J.

    1993-01-01

    Graphite furnace atomic absorption spectrophotometry is a sensitive, precise, and accurate method for the determination of chromium in natural water samples. The detection limit for this analytical method is 0.4 microg/L with a working linear limit of 25.0 microg/L. The precision at the detection limit ranges from 20 to 57 percent relative standard deviation (RSD) with an improvement to 4.6 percent RSD for concentrations more than 3 microg/L. Accuracy of this method was determined for a variety of reference standards that was representative of the analytical range. The results were within the established standard deviations. Samples were spiked with known concentrations of chromium with recoveries ranging from 84 to 122 percent. In addition, a comparison of data between graphite furnace atomic absorption spectrophotometry and direct-current plasma atomic emission spectrometry resulted in suitable agreement between the two methods, with an average deviation of +/- 2.0 microg/L throughout the analytical range.

  4. Enantiomeric determination of amino compounds with high sensitivity using the chiral reagents (+)- and (-)-1-(9-anthryl)-2-propyl chloroformate.

    PubMed

    Thorsén, G; Engström, A; Josefsson, B

    1997-10-31

    New chiral precolumn reagents, (+)- and (-)-1-(9-anthryl)-2-propyl chloroformate (APOC), are introduced for the chiral separation of amino acids and small peptides in capillary electrophoresis. Chiral separation of 17 amino acids and four small peptides as their diastereomeric 1-(9-anthryl)-2-propyl carbamate derivatives have been achieved by micellar electrokinetic chromatography. The detection limit for the derivatives is in the femtomole range with UV detection and in the attomole range with laser-induced fluorescence (LIF) detection. LIF detection was used to determine the enantiomeric excess of four APOC-derivatised peptides. The use of the new, anthracene-based reagents in conjunction with argon ion LIF makes enantiomeric determinations at ppm levels feasible. In this paper determinations below promille levels are performed without overloading the separation system.

  5. Bacterial degradation of acetone in an outdoor model stream

    USGS Publications Warehouse

    Rathbun, R.E.; Stephens, D.W.; Tai, D.Y.

    1993-01-01

    Diurnal variations of the acetone concentration in an outdoor model stream were measured with and without a nitrate supplement to determine if the nitrate supplement would stimulate bacterial degradation of the acetone. Acetone loss coefficients were computed from the diurnal data using a fitting procedure based on a Lagrangian particle model. The coefficients indicated that bacterial degradation of the acetone was occurring in the downstream part of the stream during the nitrate addition. However, the acetone concentrations stabilized at values considerably above the limit of detection for acetone determination, in contrast to laboratory respirometer studies where the acetone concentration decreased rapidly to less than the detection limit, once bacterial acclimation to the acetone had occurred. One possible explanation for the difference in behavior was the limited 6-hour residence time of the acetone in the model stream.

  6. Determination of quality parameters from statistical analysis of routine TLD dosimetry data.

    PubMed

    German, U; Weinstein, M; Pelled, O

    2006-01-01

    Following the as low as reasonably achievable (ALARA) practice, there is a need to measure very low doses, of the same order of magnitude as the natural background, and the limits of detection of the dosimetry systems. The different contributions of the background signals to the total zero dose reading of thermoluminescence dosemeter (TLD) cards were analysed by using the common basic definitions of statistical indicators: the critical level (L(C)), the detection limit (L(D)) and the determination limit (L(Q)). These key statistical parameters for the system operated at NRC-Negev were quantified, based on the history of readings of the calibration cards in use. The electronic noise seems to play a minor role, but the reading of the Teflon coating (without the presence of a TLD crystal) gave a significant contribution.

  7. Sniper detection using infrared camera: technical possibilities and limitations

    NASA Astrophysics Data System (ADS)

    Kastek, M.; Dulski, R.; Trzaskawka, P.; Bieszczad, G.

    2010-04-01

    The paper discusses technical possibilities to build an effective system for sniper detection using infrared cameras. Descriptions of phenomena which make it possible to detect sniper activities in infrared spectra as well as analysis of physical limitations were performed. Cooled and uncooled detectors were considered. Three phases of sniper activities were taken into consideration: before, during and after the shot. On the basis of experimental data the parameters defining the target were determined which are essential in assessing the capability of infrared camera to detect sniper activity. A sniper body and muzzle flash were analyzed as targets. The simulation of detection ranges was done for the assumed scenario of sniper detection task. The infrared sniper detection system was discussed, capable of fulfilling the requirements. The discussion of the results of analysis and simulations was finally presented.

  8. A comparison of simultaneous plasma, atomic absorption, and iron colorimetric determinations of major and trace constituents in acid mine waters

    USGS Publications Warehouse

    Ball, J.W.; Nordstrom, D. Kirk

    1994-01-01

    Sixty-three water samples collected during June to October 1982 from the Leviathan/Bryant Creek drainage basin were originally analyzed by simultaneous multielement direct-current plasma (DCP) atomic-emission spectrometry, flame atomic-absorption spectrometry, graphite-furnace atomic-absorption spectrometry (GFAAS) (thallium only), ultraviolet-visible spectrometry, and hydride-generation atomic-absorption spectrometry.Determinations were made for the following metallic and semi-metallic constituents: AI, As, B, Ba, Be, Bi, Cd, Ca, Cr, Co, Cu, Fe(11), Fe(total), Li, Pb, Mg, Mn, Mo, Ni, K, Sb, Se, Si, Na, Sr, TI, V, and Zn. These samples were re-analyzed later by simultaneous multielement inductively coupled plasma (ICP) atomic-emission spectrometry and Zeeman-corrected GFAAS to determine the concentrations of many of the same constituents with improved accuracy, precision, and sensitivity. The result of this analysis has been the generation of comparative concentration values for a significant subset of the solute constituents. Many of the more recently determined values replace less-than-detection values for the trace metals; others constitute duplicate analyses for the major constituents. The multiple determinations have yielded a more complete, accurate, and precise set of analytical data. They also have resulted in an opportunity to compare the performance of the plasma-emission instruments operated in their respective simultaneous multielement modes. Flame atomic-absorption spectrometry was judged best for Na and K and hydride-generation atomic-absorption spectrometry was judged best for As because of their lower detection limit and relative freedom from interelement spectral effects. Colorimetric determination using ferrozine as the color agent was judged most accurate, precise, and sensitive for Fe. Cadmium, lead, and vanadium concentrations were too low in this set of samples to enable a determination of whether ICP or DCP is a more suitable technique. Of the remaining elements, Ba, Be, Ca, Cr, Mg, Mn, Sr, and Zn have roughly equivalent accuracy, precision, and detection limit by ICP and DCP. Cobalt and Ni were determined to be better analyzed by ICP, because of lower detection limits; B, Cu, Mo, and Si were determined to be better analyzed by DCP, because of relative freedom from interferences. The determination oral by DCP was far more sensitive, owing to the use of a more sensitive wavelength, compared with the ICP. However, there is a very serious potential interference from a strong Ca emission line near the 396.15 nanometer DCP wavelength. Thus, there is no clear choice between the plasma techniques tested, for the determination oral. The ICP and DCP detection limits are typically between 0.001 and 0.5 milligrams per liter in acid mine waters. For those metals best analyzed by ICP and/or DCP, but below these limits, GFAAS is the method of choice because of its relatively greater sensitivity and specificity. Six of the elements were not determined by DCP, ICP or Zeeman-corrected GFAAS, and are not discussed in this report. These elements are: Bi, Fe(11), Li, Sb, Se, and TI.

  9. Ultrasound extracted flavonoids from four varieties of Portuguese red grape skins determined by reverse-phase high-performance liquid chromatography with electrochemical detection.

    PubMed

    Novak, Ivana; Janeiro, Patricia; Seruga, Marijan; Oliveira-Brett, Ana Maria

    2008-12-23

    Several flavonoids present in red grape skins from four varieties of Portuguese grapes were determined by reverse-phase high-performance liquid chromatography (RP-HPLC) with electrochemical detection (ECD). Extraction of flavonoids from red grape skins was performed by ultrasonication, and hydrochloric acid in methanol was used as extraction solvent. The developed RP-HPLC method used combined isocratic and gradient elution with amperometric detection with a glassy carbon-working electrode. Good peak resolution was obtained following direct injection of a sample of red grape extract in a pH 2.20 mobile phase. Eleven different flavonoids: cyanidin-3-O-glucoside (kuromanin), delphinidin-3-O-glucoside (myrtillin), petunidin-3-O-glucoside, peonidin-3-O-glucoside, malvidin-3-O-glucoside (oenin), (+)-catechin, rutin, fisetin, myricetin, morin and quercetin, can be separated in a single run by direct injection of sample solution. The limit of detection obtained for these compounds by ECD was 20-90 pg/L, 1000 times lower when compared with photodiode array (PDA) limit of detection of 12-55 ng/L. RP-HPLC-ECD was characterized by an excellent sensitivity and selectivity, and appropriate for the simultaneous determination of these electroactive phenolic compounds present in red grape skins.

  10. Validation of a high-performance liquid chromatographic method with UV detection for the determination of ethopabate residues in poultry liver.

    PubMed

    Granja, Rodrigo H M M; Niño, Alfredo M Montes; Zucchetti, Roberto A M; Niño, Rosario E Montes; Salerno, Alessandro G

    2008-01-01

    Ethopabate is frequently used in the prophylaxis and treatment of coccidiosis in poultry. Residues of this drug in food present a potential risk to consumers. A simple, rapid, and sensitive column high-performance liquid chromatographic (HPLC) method with UV detection for determination of ethopabate in poultry liver is presented. The drug is extracted with acetonitrile. After evaporation, the residue is dissolved with an acetone-hexane mixture and cleaned up by solid-phase extraction using Florisil columns. The analyte is then eluted with methanol. LC analysis is carried out on a C18 5 microm Gemini column, 15 cm x 4.6 mm. Ethopabate is quantified by means of UV detection at 270 nm. Parameters such as decision limit, detection capability, precision, recovery, ruggedness, and measurement uncertainty were calculated according to method validation guidelines provided in 2002/657/EC and ISO/IEC 17025:2005. Decision limit and detection capability were determined to be 2 and 3 microg/kg, respectively. Average recoveries from poultry samples fortified with 10, 15, and 20 microg/kg levels of ethopabate were 100-105%. A complete statistical analysis was performed on the results obtained, including an estimation of the method uncertainty. The method is to be implemented into Brazil's residue monitoring and control program for ethopabate.

  11. Two-sample discrimination of Poisson means

    NASA Technical Reports Server (NTRS)

    Lampton, M.

    1994-01-01

    This paper presents a statistical test for detecting significant differences between two random count accumulations. The null hypothesis is that the two samples share a common random arrival process with a mean count proportional to each sample's exposure. The model represents the partition of N total events into two counts, A and B, as a sequence of N independent Bernoulli trials whose partition fraction, f, is determined by the ratio of the exposures of A and B. The detection of a significant difference is claimed when the background (null) hypothesis is rejected, which occurs when the observed sample falls in a critical region of (A, B) space. The critical region depends on f and the desired significance level, alpha. The model correctly takes into account the fluctuations in both the signals and the background data, including the important case of small numbers of counts in the signal, the background, or both. The significance can be exactly determined from the cumulative binomial distribution, which in turn can be inverted to determine the critical A(B) or B(A) contour. This paper gives efficient implementations of these tests, based on lookup tables. Applications include the detection of clustering of astronomical objects, the detection of faint emission or absorption lines in photon-limited spectroscopy, the detection of faint emitters or absorbers in photon-limited imaging, and dosimetry.

  12. Determination of aflatoxin B1 levels in organic spices and herbs.

    PubMed

    Tosun, Halil; Arslan, Recep

    2013-01-01

    Organically produced spices and herbs were analyzed for determination of aflatoxin B1 (AFB1) by ELISA using immunoaffinity column. For this purpose 93 organic spices and 37 organic herbs were randomly selected from organic markets and organic shops in Turkey. AFB1 was detected in 58 organic spice and 32 organic herb samples. Among organic spice samples, the maximum value was detected in cinnamon sample (53 μg/kg). AFB1 was not detected in thyme samples. AFB1 levels of 41 organic spice samples were above the EU regulatory limit (5 μg/kg). Among organic herb samples the highest concentration of AFB1 (52.5 μg/kg) was detected in a rosehip sample. AFB1 levels of 21 organic herb samples were above the regulatory limits of the European Union. These results showed that more stringent measures must be taken for the prevention of mold contamination in the production of organic spices and herbs.

  13. Determination of Aflatoxin B1 Levels in Organic Spices and Herbs

    PubMed Central

    Tosun, Halil; Arslan, Recep

    2013-01-01

    Organically produced spices and herbs were analyzed for determination of aflatoxin B1 (AFB1) by ELISA using immunoaffinity column. For this purpose 93 organic spices and 37 organic herbs were randomly selected from organic markets and organic shops in Turkey. AFB1 was detected in 58 organic spice and 32 organic herb samples. Among organic spice samples, the maximum value was detected in cinnamon sample (53 μg/kg). AFB1 was not detected in thyme samples. AFB1 levels of 41 organic spice samples were above the EU regulatory limit (5 μg/kg). Among organic herb samples the highest concentration of AFB1 (52.5 μg/kg) was detected in a rosehip sample. AFB1 levels of 21 organic herb samples were above the regulatory limits of the European Union. These results showed that more stringent measures must be taken for the prevention of mold contamination in the production of organic spices and herbs. PMID:23766719

  14. A liquid-phase microextraction method, combining a dual gauge microsyringe with a hollow fiber membrane, for the determination of organochlorine pesticides in aqueous solution by gas chromatography/ion trap mass spectrometry.

    PubMed

    Yan, Chih-Hao; Wu, Hui-Fen

    2004-01-01

    A liquid-phase microextraction (LPME) method has been demonstrated for the extraction and determination of organochlorine pesticides (OCPs) in aqueous solution. The method combines a dual gauge microsyringe with a hollow fiber membrane (LPME/DGM-HF) followed by detection by gas chromatography/ion trap mass spectrometry (GC/ITMS). The advantages include speed, low solvent and sample consumption, simplicity and ease of use. The extraction time, solvent selection, salt concentration and sample stirring rate have been investigated in order to optimize extraction efficiency. The viability is evaluated by measuring the linearity and detection limit of the five OCPs in aqueous solution. Detection linearity for the OCPs has been achieved over a range of concentrations between 1 and 500 microg/L (r2 > 0.930), with a detection limit of 0.1 microg/L for each OCP. Copyright 2004 John Wiley & Sons, Ltd.

  15. Specific determination of bromate in bread by ion chromatography with ICP-MS.

    PubMed

    Akiyama, Takumi; Yamanaka, Michiko; Date, Yukiko; Kubota, Hiroki; Nagaoka, Megumi Hamano; Kawasaki, Yoko; Yamazaki, Takeshi; Yomota, Chikako; Maitani, Tamio

    2002-12-01

    A sensitive method for detecting bromate in bread by ion chromatography with inductively-coupled plasma mass spectrometry (IC/ICP-MS) was developed. Bromate was extracted from bread with water. The clean-up procedure included a 0.2 micron filter, a C18 cartridge for defatting, a silver cartridge to remove halogen anions, a centrifugal ultrafiltration unit to remove proteins, and a cation-exchange cartridge to remove silver ions. A 500 microL sample solution was applied to IC/ICP-MS. The detection limit and the quantitation limit of bromate in the solution were 0.3 ng/mL and 1.0 ng/mL, expressed as HBrO3, respectively, which corresponded to 2 ng/g and 5 ng/g, respectively, in bread. Recovery of bromate was about 90%, and the CV was about 2%. Based on the detection limit in solution and recovery from bread, the detection limit of bromate in bread was estimated to be 2 ng/g.

  16. Eye movements during change detection: implications for search constraints, memory limitations, and scanning strategies.

    PubMed

    Zelinsky, G J

    2001-02-01

    Search, memory, and strategy constraints on change detection were analyzed in terms of oculomotor variables. Observers viewed a repeating sequence of three displays (Scene 1-->Mask-->Scene 2-->Mask...) and indicated the presence-absence of a changing object between Scenes 1 and 2. Scenes depicted real-world objects arranged on a surface. Manipulations included set size (one, three, or nine items) and the orientation of the changing objects (similar or different). Eye movements increased with the number of potentially changing objects in the scene, with this set size effect suggesting a relationship between change detection and search. A preferential fixation analysis determined that memory constraints are better described by the operation comparing the pre- and postchange objects than as a capacity limitation, and a scanpath analysis revealed a change detection strategy relying on the peripheral encoding and comparison of display items. These findings support a signal-in-noise interpretation of change detection in which the signal varies with the similarity of the changing objects and the noise is determined by the distractor objects and scene background.

  17. Detection of Salmonella enterica Serovar Typhimurium by Using a Rapid, Array-Based Immunosensor

    PubMed Central

    Taitt, Chris Rowe; Shubin, Yura S.; Angel, Roselina; Ligler, Frances S.

    2004-01-01

    The multianalyte array biosensor (MAAB) is a rapid analysis instrument capable of detecting multiple analytes simultaneously. Rapid (15-min), single-analyte sandwich immunoassays were developed for the detection of Salmonella enterica serovar Typhimurium, with a detection limit of 8 × 104 CFU/ml; the limit of detection was improved 10-fold by lengthening the assay protocol to 1 h. S. enterica serovar Typhimurium was also detected in the following spiked foodstuffs, with minimal sample preparation: sausage, cantaloupe, whole liquid egg, alfalfa sprouts, and chicken carcass rinse. Cross-reactivity tests were performed with Escherichia coli and Campylobacter jejuni. To determine whether the MAAB has potential as a screening tool for the diagnosis of asymptomatic Salmonella infection of poultry, chicken excretal samples from a private, noncommercial farm and from university poultry facilities were tested. While the private farm excreta gave rise to signals significantly above the buffer blanks, none of the university samples tested positive for S. enterica serovar Typhimurium without spiking; dose-response curves of spiked excretal samples from university-raised poultry gave limits of detection of 8 × 103 CFU/g. PMID:14711637

  18. Utility of gold nanoparticles in luminescence determination of trovafloxacin: comparison of chemiluminescence and fluorescence detection.

    PubMed

    Alarfaj, Nawal A; El-Tohamy, Maha F

    2015-12-01

    Two novel sensitive sequential injection chemiluminescence analysis and fluorescence methods for trovafloxacin mesylate detection have been developed. The methods were based on the enhancement effect of gold nanoparticles on luminol-ferricyanide-trovafloxacin and europium(III)-trovafloxacin complex systems. The optimum conditions for both detection methods were investigated. The chemiluminescence signal was emitted due to the enhanced effect of gold nanoparticles on the reaction of luminol-ferricyanide-trovafloxacin in an alkaline medium. The response was linear over a concentration range of 1.0 × 10(-9) to 1.0 × 10(-2) mol/L (%RSD = 1.3), (n = 9, r = 0.9991) with a detection limit of 1.7 × 10(-10) mol/L (S/N = 3). The weak fluorescence intensity signal of the oxidation complex of europium(III)-trovafloxacin was strongly enhanced by gold nanoparticles and detected at λex = 330 and λem = 540 nm. Fluorescence detection enabled the determination of trovafloxacin mesylate over a linear range of 1.0 × 10(-8) to 1.0 × 10(-3) mol/L (%RSD = 1.2), (n = 6, r = 0.9993) with a detection limit of 3.3 × 10(-9) mol/L. The proposed methods were successfully applied to the determination of the studied drug in its bulk form and in pharmaceutical preparations. The results were treated statistically and compared with those obtained from other reported methods. Copyright © 2015 John Wiley & Sons, Ltd.

  19. Activities of JAXA's Innovative Technology Center on Space Debris Observation

    NASA Astrophysics Data System (ADS)

    Yanagisawa, T.; Kurosaki, H.; Nakajima, A.

    The innovative technology research center of JAXA is developing observational technologies for GEO objects in order to cope with the space debris problem. The center had constructed the optical observational facility for space debris at Mt. Nyukasa, Nagano in 2006. As observational equipments such as CCD cameras and telescopes were set up, the normal observation started. In this paper, the detail of the facilities and its activities are introduced. The observational facility contains two telescopes and two CCD cameras. The apertures of the telescopes are 35cm and 25 cm, respectively. One CCD camera in which 2K2K chip is installed can observe a sky region of 1.3 times 1.3-degree using the 35cm telescope. The other CCD camera that contains two 4K2K chips has an ability to observe 2.6 times 2.6-degree's region with the 25cm telescope. One of our main objectives is to detect faint GEO objects that are not catalogued. Generally, the detection limit of GEO object is determined by the aperture of the telescope. However, by improving image processing techniques, the limit may become low. We are developing some image processing methods that use many CCD frames to detect faint objects. We are trying to use FPGA (Field Programmable Gate Array) system to reduce analyzing time. By applying these methods to the data taken by a large telescope, the detection limit will be significantly lowered. The orbital determination of detected GEO debris is one of the important things to do. Especially, the narrow field view of an optical telescope hinders us from re-detection of the GEO debris for the orbital determination. Long observation time is required for one GEO object for the orbital determination that is inefficient. An effective observation strategy should be considered. We are testing one observation method invented by Umehara that observes one inertia position in the space. By observing one inertia position for two nights, a GEO object that passed through the position in the first night must pass through the position in the second night. The rough orbit is determined from two nights' data. The test observation showed that this method was able to detect many GEO objects and determined their orbits by three nights' observations. We also joined the campaign observations of IADC(Inter-Agency Space Debris Coordination Committee). By analyzing the observed data with the method that we developed, 88 catalogued and 38 un-catalogued objects were detected. The magnitude of the faintest object detected in this campaign observation was 18.5. The object is un-detectable by human inspection.

  20. A novel assay method for the trace determination of Th and U in copper and lead using inductively coupled plasma mass spectrometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    LaFerriere, Brian D.; Maiti, Tapas C.; Arnquist, Isaac J.

    2015-03-01

    This study describes a novel sample preparation and assay method developed in support of the MAJORANA DEMONSTRATOR experiment for the determination of thorium and uranium levels in copper and lead shielding components. Meticulously clean sample preparation methods combined with novel anion exchange separations for analyte pre-concentration and matrix removal were developed. Quantification was performed by inductively coupled plasma mass spectrometry. Detection limits of 0.0084 pg 232Th/g and 0.0106 pg 238U/g were determined for copper, while detection limits of 0.23 pg 232Th/g and 0.46 pg 238U/g were achieved for lead. These methods allow the Majorana Collaboration to accurately assay detector componentsmore » and ensure that the experiment’s stringent radiopurity requirements are met.« less

  1. Lysergic acid amide as chemical marker for the total ergot alkaloids in rye flour - Determination by high-performance thin-layer chromatography-fluorescence detection.

    PubMed

    Oellig, Claudia

    2017-07-21

    Ergot alkaloids are generally determined by high-performance liquid chromatography (HPLC) coupled to fluorescence detection (FLD) or mass selective detection, analyzing the individual compounds. However, fast and easy screening methods for the determination of the total ergot alkaloid content are more suitable, since for monitoring only the sum of the alkaloids is relevant. The herein presented screening uses lysergic acid amide (LSA) as chemical marker, formed from ergopeptine alkaloids, and ergometrine for the determination of the total ergot alkaloids in rye with high-performance thin-layer chromatography-fluorescence detection (HPTLC-FLD). An ammonium acetate buffered extraction step was followed by liquid-liquid partition for clean-up before the ergopeptine alkaloids were selectively transformed to LSA and analyzed by HPTLC-FLD on silica gel with isopropyl acetate/methanol/water/25% ammonium hydroxide solution (80:10:3.8:1.1, v/v/v/v) as the mobile phase. The enhanced native fluorescence of LSA and unaffected ergometrine was used for quantitation without any interfering matrix. Limits of detection and quantitation were 8 and 26μg LSA/kg rye, which enables the determination of the total ergot alkaloids far below the applied quality criterion limit for rye. Close to 100% recoveries for different rye flours at relevant spiking levels were obtained. Thus, reliable results were guaranteed, and the fast and efficient screening for the total ergot alkaloids in rye offers a rapid alternative to the HPLC analysis of the individual compounds. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Development of duplex SYBR Green I-based real-time quantitative reverse-transcription PCR for detection and discrimination of grapevine viruses

    USDA-ARS?s Scientific Manuscript database

    A SYBR® Green-based real-time quantitative reverse transcription PCR (qRT-PCR) assay in combination with melt curve analysis (MCA) was developed for the detection of nine grapevine viruses. The detection limits for singleplex qRT-PCR for all nine grapevine viruses were determined to be in the range ...

  3. Methods of analysis by the U.S. Geological Survey National Water Quality Laboratory; determination of 86 volatile organic compounds in water by gas chromatography/mass spectrometry, including detections less than reporting limits

    USGS Publications Warehouse

    Connor, Brooke F.; Rose, Donna L.; Noriega, Mary C.; Murtaugh, Lucinda K.; Abney, Sonja R.

    1998-01-01

    This report presents precision and accuracy data for volatile organic compounds (VOCs) in the nanogram-per-liter range, including aromatic hydrocarbons, reformulated fuel components, and halogenated hydrocarbons using purge and trap capillary-column gas chromatography/mass spectrometry. One-hundred-four VOCs were initially tested. Of these, 86 are suitable for determination by this method. Selected data are provided for the 18 VOCs that were not included. This method also allows for the reporting of semiquantitative results for tentatively identified VOCs not included in the list of method compounds. Method detection limits, method performance data, preservation study results, and blank results are presented. The authors describe a procedure for reporting low-concentration detections at less than the reporting limit. The nondetection value (NDV) is introduced as a statistically defined reporting limit designed to limit false positives and false negatives to less than 1 percent. Nondetections of method compounds are reported as ?less than NDV.? Positive detections measured at less than NDV are reported as estimated concentrations to alert the data user to decreased confidence in accurate quantitation. Instructions are provided for analysts to report data at less than the reporting limits. This method can support the use of either method reporting limits that censor detections at lower concentrations or the use of NDVs as reporting limits. The data-reporting strategy for providing analytical results at less than the reporting limit is a result of the increased need to identify the presence or absence of environmental contaminants in water samples at increasingly lower concentrations. Long-term method detection limits (LTMDLs) for 86 selected compounds range from 0.013 to 2.452 micrograms per liter (?g/L) and differ from standard method detection limits (MDLs) in that the LTMDLs include the long-term variance of multiple instruments, multiple operators, and multiple calibrations over a longer time. For these reasons, LTMDLs are expected to be slightly higher than standard MDLs. Recoveries for all of the VOCs tested ranged from 36 (tert-butyl formate) to 155 percent (pentachlorobenzene). The majority of the compounds ranged from 85 to 115 percent recovery and had less than 5 percent relative standard deviation for concentrations spiked between 1 to 500 ?g/L in volatile blank-, surface-, and ground-water samples. Recoveries of 60 set spikes at low concentrations ranged from 70 to 114 percent (1,2,3- trimethylbenzene and acetone). Recovery data were collected over 6 months with multiple instruments, operators, and calibrations. In this method, volatile organic compounds are extracted from a water sample by actively purging with helium. The VOCs are collected onto a sorbent trap, thermally desorbed, separated by a Megabore gas chromatographic capillary column, and finally determined by a full-scan quadrupole mass spectrometer. Compound identification is confirmed by the gas chromatographic retention time and by the resultant mass spectrum, typically identified by three unique ions. An unknown compound detected in a sample can be tentatively identified by comparing the unknown mass spectrum to reference spectra in the mass-spectra computer-data system library compiled by the National Institute of Standards and Technology.

  4. Approaching the Limit in Atomic Spectrochemical Analysis.

    ERIC Educational Resources Information Center

    Hieftje, Gary M.

    1982-01-01

    To assess the ability of current analytical methods to approach the single-atom detection level, theoretical and experimentally determined detection levels are presented for several chemical elements. A comparison of these methods shows that the most sensitive atomic spectrochemical technique currently available is based on emission from…

  5. Determination of bisphenol A in human serum by high-performance liquid chromatography with multi-electrode electrochemical detection.

    PubMed

    Inoue, K; Kato, K; Yoshimura, Y; Makino, T; Nakazawa, H

    2000-11-10

    A simple and sensitive method using high-performance liquid chromatography with multi-electrode electrochemical detection (HPLC-ED) including a coulometric array of four electrochemical sensors has been developed for the determination of bisphenol A in water and human serum. For good separation and detection of bisphenol A, a CAPCELL PAK UG 120 C18 reversed-phase column and a mobile phase consisting of 0.3% phosphoric acid-acetonitrile (60:40) were used. The detection limit obtained by the HPLC-ED method was 0.01 ng/ml (0.5 pg), which was more than 3000-times higher than the detection limit obtained by the ultraviolet (UV) method, and more than 200-times higher than the detection limit obtained by the fluorescence (FL) method. Bisphenol A in water and serum samples was pretreated by solid-phase extraction (SPE) after removing possible contamination derived from a plastic SPE cartridges and water used for the pretreatment. A trace amount (ND approximately 0.013 ng/ml) of bisphenol A was detected from the parts of cartridges (filtration column, sorbent bed and frits) by extraction with methanol, and it was completely removed by washing with at least 15 ml of methanol in the operation process. The concentrations of bisphenol A in tap water and Milli-Q-purified water were found to be 0.01 and 0.02 ng/ml, respectively. For that reason, bisphenol A-free water was made to trap bisphenol A in water using an Empore disk. In every pretreatment, SPE methods using bisphenol A-free water and washing with 15 ml of methanol were done in water and serum samples. The yields obtained from the recovery tests using water to which 0.5 or 0.05 ng/ml of bisphenol A was added were 83.8 to 98.2%, and the RSDs were 3.4 to 6.1%, respectively. The yields obtained from the recovery tests by OASIS HLB using serum to which 1.0 ng/ml or 0.1 ng/ml of bisphenol A was added were 79.0% and 87.3%, and the RSDs were 5.1% and 13.5%, respectively. The limits of quantification in water and serum sample were 0.01 ng/ml and 0.05 ng/ml, respectively. The method was applied to the determination of bisphenol A in healthy human serum sample, and the obtained detection was 0.32 ng/ml. From these results, the HPLC-ED method should be the most useful in the determination of bisphenol A at low concentration levels in water and biological samples.

  6. Sensitive indoor air monitoring of formaldehyde and other carbonyl compounds using the 2,4-dinitrophenylhydrazine method.

    PubMed

    Sandner, F; Dott, W; Hollender, J

    2001-03-01

    The toxic potential of formaldehyde and other aliphatic/aromatic carbonyl compounds requires the determination of even low amounts of these compounds in indoor air. The existing DFG-method for workplace monitoring using adsorption at 2,4-dinitrophenylhydrazine (DNPH)-coated sorbents followed by HPLC-UV/DAD analysis of the extract was modified in order to decrease detection limits. The improvement included an increase in volume and rate of the air sampling, testing applicability of different adsorption materials and a decrease of the extraction volume of the hydrazones. 13 DNPH-derivatives could be separated well on a RP18-column followed by UV/DAD-detection at 365 nm. Recovery rates of 70-100% were determined (apart from acetone with 19%) using dynamically produced artifical carbonyl atmospheres. Detection limits of 0.05-0.4 microgram/m3 were reached by this method which are sufficient for indoor air monitoring.

  7. A new dual-channel optical signal probe for Cu2+ detection based on morin and boric acid.

    PubMed

    Wang, Peng; Yuan, Bin Fang; Li, Nian Bing; Luo, Hong Qun

    2014-01-01

    In this work we utilized the common analytical reagent morin to develop a new a dual-channel, cost-effective, and sensitive method for determination of Cu(2+). It is found that morin is only weakly fluorescent by itself, but forms highly fluorescent complexes with boric acid. Moreover, the fluorescence of complexes of morin with boric acid is quenched linearly by Cu(2+) in a certain concentration range. Under optimum conditions, the fluorescence quenching efficiency was linearly proportional to the concentration of cupric ions in the range of 0.5-25 μM with high sensitivity, and the detection limit for Cu(2+) was 0.38 μM. The linear range was 1-25 μM determined by spectrophotometry, and the detection limit for cupric ions was 0.8 μM. Furthermore, the mechanism of sensitive fluorescence quenching response of morin to Cu(2+) is discussed.

  8. Evaluation of a new ultrasensitive assay for cardiac troponin I.

    PubMed

    Casals, Gregori; Filella, Xavier; Bedini, Josep Lluis

    2007-12-01

    We evaluated the analytical and clinical performance of a new ultrasensitive cardiac troponin I assay (cTnI) on the ADVIA Centaur system (TnI-Ultra). The evaluation included the determination of detection limit, within-assay and between-assay variation and comparison with two other non-ultrasensitive methods. Moreover, cTnI was determined in 120 patients with acute chest pain with three methods. To evaluate the ability of the new method to detect MI earlier, it was assayed in 8 MI patients who first tested negative then positive by the other methods. The detection limit was 0.009 microg/L and imprecision was <10% at all concentrations evaluated. In comparison with two other methods, 10% of the anginas diagnosed were recategorized to MI. The ADVIA Centaur TnI-Ultra assay presented high reproducibility and high sensitivity. The use of the recommended lower cutpoint (0.044 microg/L) implied an increased and earlier identification of MI.

  9. Qualitative analysis of seized cocaine samples using desorption electrospray ionization- mass spectrometry (DESI-MS).

    PubMed

    Stojanovska, Natasha; Tahtouh, Mark; Kelly, Tamsin; Beavis, Alison; Fu, Shanlin

    2015-05-01

    Desorption electrospray ionization - mass spectrometry (DESI-MS) is a useful technique for the qualitative analysis of compounds found in seized drug material. In this study, DESI-MS was utilized in the screening analysis of illicit cocaine samples. The technique was also applied to the geographical origin determination of these samples. The limit of detection was determined to be 24.3 µg (or 3.47 µg/mm(2) ) and the analysis time was less than 1 minute per sample. The intra-day and inter-day precision for the detection of cocaine was 11 % and 42 %, respectively; therefore the quantitative data provided by DESI-MS was limited in its use for accurate determination of cocaine concentration in a sample. Using the quadrupole time-of-flight (QTOF) mass spectrometer, the presence of cocaine and impurities detected were confirmed by accurate tandem MS data. The qualitative chemical profiles obtained using DESI-MS were compared to two popular analysis techniques, GC-MS and LC-MS. The effects of a range of adulterants including caffeine, procaine, levamisole, lignocaine, paracetamol, and atropine on the detectability of cocaine were also investigated. It was found that the addition of these adulterants in a cocaine sample did not prevent the detection of the analyte itself (there was slight enhancement in some samples), which was useful in drug detection. The detection of truxillines in the seized samples by DESI-MS aided in the preliminary determination of geographical origin, i.e., Bolivian, Peruvian or Colombian leaf origin. The application of DESI-MS to the qualitative analysis and screening of seized cocaine samples demonstrates the potential and applicability of the technique to the fast chemical profiling of illicit samples. Copyright © 2014 John Wiley & Sons, Ltd.

  10. Determination of ammonium in river water and sewage samples by capillary zone electrophoresis with direct UV detection.

    PubMed

    Fukushi, Keiichi; Ito, Hideyuki; Kimura, Kenichi; Yokota, Kuriko; Saito, Keiitsu; Chayama, Kenji; Takeda, Sahori; Wakida, Shin-ichi

    2006-02-17

    We developed capillary zone electrophoresis (CZE) with direct UV detection for determination of ammonium in environmental water samples. Ammonium in the samples was partly converted into ammonia in the alkaline background electrolyte (BGE) during migration and was detected by molecular absorption of ammonia at 190 nm in approximately 7 min. The limit of detection (LOD) for ammonium was 0.24 mg/l (as nitrogen) at a signal-to-noise ratio of three. The respective values of the relative standard deviation (RSD) of peak area, peak height, and migration time for ammonium were 2.1, 1.8, and 0.46%. Major alkali and alkaline earth metal ions coexisting in the samples did not interfere with ammonium determination by the proposed method. The proposed method determined ammonium in surface water and sewage samples. The results were compared to those obtained using ion chromatography (IC).

  11. Investigation of detection limits for solutes in water measured by laser raman spectrometry

    USGS Publications Warehouse

    Goldberg, M.C.

    1977-01-01

    The influence of experimental parameters on detection sensitivity was determined for laser Raman analysis of dissolved solutes in water. Individual solutions of nitrate, sulfate, carbonate, bicarbonate, monohydrogen phosphate, dihydrogen phosphate, acetate ion, and acetic acid were measured. An equation is derived which expresses the signal-to-noise ratio in terms of solute concentration, measurement time, spectral slit width, laser power fluctuations, and solvent background intensity. Laser beam intensity fluctuations at the sample and solvent background intensity are the most important limiting factors.

  12. An overview of LIGO and Virgo -- status and plans

    NASA Astrophysics Data System (ADS)

    Miller, John

    2014-06-01

    Interferometric gravitational-wave detectors, the most sensitive position meters ever operated, aim to detect the motion of massive bodies throughout the universe by pushing precision measurement to the standard quantum limit and beyond. A global network of these detectors is currently under construction, promising unprecedented sensitivity and the ability to determine the sky position of any detected signals. I will describe the current status and expected performance of this network with a focus on limiting noise sources and the techniques currently being developed to combat them.

  13. Methods for the preparation and analysis of solids and suspended solids for methylmercury

    USGS Publications Warehouse

    DeWild, John F.; Olund, Shane D.; Olson, Mark L.; Tate, Michael T.

    2004-01-01

    This report presents the methods and method performance data for the determination of methylmercury concentrations in solids and suspended solids. Using the methods outlined here, the U.S. Geological Survey's Wisconsin District Mercury Laboratory can consistently detect methylmercury in solids and suspended solids at environmentally relevant concentrations. Solids can be analyzed wet or freeze dried with a minimum detection limit of 0.08 ng/g (as-processed). Suspended solids must first be isolated from aqueous matrices by filtration. The minimum detection limit for suspended solids is 0.01 ng per filter resulting in a minimum reporting limit ranging from 0.2 ng/L for a 0.05 L filtered volume to 0.01 ng/L for a 1.0 L filtered volume. Maximum concentrations for both matrices can be extended to cover nearly any amount of methylmercury by limiting sample size.

  14. Solid phase microextraction applied to the analysis of organophosphorus insecticides in fruits.

    PubMed

    Fytianos, K; Raikos, N; Theodoridis, G; Velinova, Z; Tsoukali, H

    2006-12-01

    Trace amounts of organophosphorus pesticides (OPs) were determined in various fruits by headspace solid phase microextraction (HS-SPME) and gas chromatography-nitrogen phosphorous detection (GC-NPD). Sampling from the headspace enhanced method selectivity, whereas at the same time improved fiber life time and method sensitivity. Diazinon, parathion, methyl parathion, malathion and fenithrothion were determined in various fruits: more than 150 samples of 21 types of fruits were studied. SPME-GC-NPD provided a useful and very efficient analytical tool: method linearity ranged from 1.2 to 700 ng/ml. Limits of detection (LODs) and quantitation (LOQs) ranged from 0.03 to 3 ng/ml and 0.12 to 10 ng/ml respectively, values well below the residue limits set by the EU. Less than 2% of the samples were found positive containing amounts higher than the EU limits. The effect of fruit peeling and washing was also investigated.

  15. Ground-water levels and water-quality data for wells in the Spring Creek area near Arnold Air Force Base, Tennessee, April and May 2000

    USGS Publications Warehouse

    Williams, Shannon D.; Aycock, Robert A.

    2001-01-01

    Arnold Air Force Base (AAFB) occupies about 40,000 acres in Coffee and Franklin Counties, Tennessee. Numerous site-specific ground-water contamination investigations have been conducted at designated solid waste management units (SWMU?s) at AAFB. Several synthetic volatile organic compounds (VOC?s), primarily chlorinated solvents, have been identified in groundwater samples collected from monitoring wells near SWMU 8 in the Spring Creek area. During April and May 2000, a study of the groundwater resources in the Spring Creek area was conducted to determine if VOC?s from AAFB have affected local private water supplies and to advance understanding of the ground-water-flow system in this area. The study focused on sampling private wells located within the Spring Creek area that are used as a source of drinking water. Ground-water-flow directions were determined by measuring water levels in wells and constructing a potentiometric-surface map of the Manchester aquifer in the study area. Data were collected from a total of 35 private wells and 22 monitoring wells during the period of study. Depths to ground water were determined for 22 of the private wells and all 22 of the monitoring wells. The wells ranged in depth from 21 to 105 feet. Water-level altitudes ranged from 930 to 1,062 feet above sea level. Depths to water ranged from 8 to 83 feet below land surface. Water-quality samples were collected from 29 private wells which draw water from either gravel zones in the upper part of the Manchester aquifer, fractured bedrock in the lower part of the Manchester aquifer, or a combination of these two zones. Concentrations of 50 of the 55 VOC?s analyzed for were less than method detection limits. Chloroform, acetone, chloromethane, 2-butanone, and tetrachloroethylene were detected in concentrations exceeding the method detection limits. Only chloroform and acetone were detected in concentrations equal to or exceeding reporting limits. Chloroform was detected in a sample from one well at a concentration of 1.2 micrograms per liter (?g/L). Acetone was detected in a sample from another well at a concentration of 10 ?g/L. Acetone also was detected in a duplicate sample from the same well at an estimated concentration of 7.2 ?g/L, which is less than the reporting limit for acetone. The only contaminant of concern detected was tetrachloroethylene. Tetrachloroethylene was detected in only one sample, and this detection was at an estimated concentration below the reporting limit. None of the VOC concentrations exceeded drinking water maximum contaminant levels for public water systems.

  16. Determination of thiopental in urine sample with high-performance liquid chromatography using iodine-azide reaction as a postcolumn detection system.

    PubMed

    Zakrzewski, Robert; Ciesielski, Witold

    2005-09-25

    The reaction between iodine and azide ions induced by thiopental was utilized as a postcolumn reaction for chromatographic determination of thiopental. The method is based on the separation of thiopental on an Nova-Pak CN HP column with an acetonitrile-aqueous solution of sodium azide as a mobile phase, followed by spectrophotometric measurement of the residual iodine (lambda=350 nm) from the postcolumn iodine-azide reaction induced by thiopental after mixing an iodine solution containing iodide ions with the column effluent containing azide ions and thiopental. Chromatograms obtained for thiopental showed negative peaks as a result of the decrease in background absorbance. The detection limit (defined as S/N=3) was 20 nM (0.4 pmol injected amount) for thiopental. Calibration graphs, plotted as peak area versus concentrations, were linear from 40 nM. The elaborated method was applied to determine thiopental in urine samples. The detection limit (defined as S/N=3) was 0.025 nmol/ml urine. Calibration graphs, plotted as peak area versus concentrations, were linear from 0.05 nmol/ml urine. Authentic urine samples were analyzed, thiopental was determined at nmol/ml urine level.

  17. Determination of mutagenic amines in water and food samples by high pressure liquid chromatography with amperometric detection using a multiwall carbon nanotubes-glassy carbon electrode.

    PubMed

    Bueno, Ana María; Marín, Miguel Ángel; Contento, Ana María; Ríos, Ángel

    2016-02-01

    A chromatographic method, using amperometric detection, for the sensitive determination of six representative mutagenic amines was developed. A glassy carbon electrode (GCE), modified with multiwall carbon nanotubes (GCE-CNTs), was prepared and its response compared to a conventional glassy carbon electrode. The chromatographic method (HPLC-GCE-CNTs) allowed the separation and the determination of heterocyclic aromatic amines (HAAs) classified as mutagenic amines by the International Agency for Research of Cancer. The new electrode was systematically studied in terms of stability, sensitivity, and reproducibility. Statistical analysis of the obtained data demonstrated that the modified electrode provided better sensitivity than the conventional unmodified ones. Detection limits were in the 3.0 and 7.5 ng/mL range, whereas quantification limits ranged between 9.5 and 25.0 ng/mL were obtained. The applicability of the method was demonstrated by the determination of the amines in several types of samples (water and food samples). Recoveries indicate very good agreement between amounts added and those found for all HAAs (recoveries in the 92% and 105% range). Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. Identifying Roads and Trains Under Canopy Using Lidar

    DTIC Science & Technology

    2007-09-01

    OVERVIEW...................................................................................................17 B. DATA SET LOCATIONS ...imaging systems to detect, track and locate operations in these dense canopy environments is severely limited. One possibility for “seeing through...in detecting, tracking and locating illicit operations previously undetectable. The purpose of this thesis is to determine if roads and trails2 are

  19. Detection of β-Lactams and Chloramphenicol Residues in Raw Milk-Development and Application of an HPLC-DAD Method in Comparison with Microbial Inhibition Assays.

    PubMed

    Karageorgou, Eftychia; Christoforidou, Sofia; Ioannidou, Maria; Psomas, Evdoxios; Samouris, Georgios

    2018-06-01

    The present study was carried out to assess the detection sensitivity of four microbial inhibition assays (MIAs) in comparison with the results obtained by the High Performance Liquid Chromatography with Diode-Array Detection (HPLC-DAD) method for antibiotics of the β-lactam group and chloramphenicol in fortified raw milk samples. MIAs presented fairly good results when detecting β-lactams, whereas none were able to detect chloramphenicol at or above the permissible limits. HPLC analysis revealed high recoveries of examined compounds, whereas all detection limits observed were lower than their respective maximum residue limits (MRL) values. The extraction and clean-up procedure of antibiotics was performed by a modified matrix solid phase dispersion procedure using a mixture of Plexa by Agilent and QuEChERS as a sorbent. The HPLC method developed was validated, determining the accuracy, precision, linearity, decision limit, and detection capability. Both methods were used to monitor raw milk samples of several cows and sheep, obtained from producers in different regions of Greece, for the presence of examined antibiotic residues. Results obtained showed that MIAs could be used effectively and routinely to detect antibiotic residues in several milk types. However, in some cases, spoilage of milk samples revealed that the kits' sensitivity could be strongly affected, whereas this fact does not affect the effectiveness of HPLC-DAD analysis.

  20. High-sensitivity detection of cardiac troponin I with UV LED excitation for use in point-of-care immunoassay

    PubMed Central

    Rodenko, Olga; Eriksson, Susann; Tidemand-Lichtenberg, Peter; Troldborg, Carl Peder; Fodgaard, Henrik; van Os, Sylvana; Pedersen, Christian

    2017-01-01

    High-sensitivity cardiac troponin assay development enables determination of biological variation in healthy populations, more accurate interpretation of clinical results and points towards earlier diagnosis and rule-out of acute myocardial infarction. In this paper, we report on preliminary tests of an immunoassay analyzer employing an optimized LED excitation to measure on a standard troponin I and a novel research high-sensitivity troponin I assay. The limit of detection is improved by factor of 5 for standard troponin I and by factor of 3 for a research high-sensitivity troponin I assay, compared to the flash lamp excitation. The obtained limit of detection was 0.22 ng/L measured on plasma with the research high-sensitivity troponin I assay and 1.9 ng/L measured on tris-saline-azide buffer containing bovine serum albumin with the standard troponin I assay. We discuss the optimization of time-resolved detection of lanthanide fluorescence based on the time constants of the system and analyze the background and noise sources in a heterogeneous fluoroimmunoassay. We determine the limiting factors and their impact on the measurement performance. The suggested model can be generally applied to fluoroimmunoassays employing the dry-cup concept. PMID:28856047

  1. Development of ochratoxin a in cereal by chemiluminescence enzyme immunoassay

    NASA Astrophysics Data System (ADS)

    Li, Min; Liu, Renrong; Zhu, Lixin; Chen, Zhenzhen

    2017-11-01

    A rapid, simple and sensitive chemiluminescence enzyme immunoassay method (CLEIA) was established to detect ochratoxin A (OTA) in cereal. Optimal conditions including antibody dilution ratio and enzyme conjugate, ionic strength, pH value and organic solvent. Established indirect competition inhibition curve to determine the linear working range, detection limit and recovery rate. Results: The 50% inhibitory concentration and the detection limit of the CLEIA were78.8pg/mL and 14.86 pg/mL, respectively, with a linear range of 0.015-0.4ng/mL. At 1∼4μpg/kg fortified levels in wheat, mean recoveries ranged from 67.47% to100.35%.

  2. Laser-induced fluorescence microscopic system using an optical parametric oscillator for tunable detection in microchip analysis.

    PubMed

    Kumemura, Momoko; Odake, Tamao; Korenaga, Takashi

    2005-06-01

    A laser-induced fluorescence microscopic system based on optical parametric oscillation has been constructed as a tunable detector for microchip analysis. The detection limit of sulforhodamine B (Ex. 520 nm, Em. 570 nm) was 0.2 mumol, which was approximately eight orders of magnitude better than with a conventional fluorophotometer. The system was applied to the determination of fluorescence-labeled DNA (Ex. 494 nm, Em. 519 nm) in a microchannel and the detection limit reached a single molecule. These results showed the feasibility of this system as a highly sensitive and tunable fluorescence detector for microchip analysis.

  3. Fluorine-Induced Chemiluminescence Detection of Biologically Methylated Tellurium, Selenium, and Sulfur Compounds and Methyldithiocarbhydrazide as a Formaldehyde Derivatization Reagent

    NASA Astrophysics Data System (ADS)

    Chasteen, Thomas Girard

    1990-01-01

    The first part of this dissertation describes capillary chromatography coupled to a fluorine-induced chemiluminescence detector as a sensitive method by which biologically methylated metalloids can be determined in the presence of high concentrations of potentially interfering molecules. With a wide linear range and excellent sensitivity, this method was applied to the detection of dimethyl selenide (DMSe), dimethyl diselenide (DMDSe), and dimethyl telluride (DMTe), often found in biological environments in the presence of interfering methylated sulfur gases, such as methanethiol, dimethyl sulfide, dimethyl disulfide, and dimethyl trisulfide. Detection limits for DMSe, DMDSe, and DMTe were 30, 9, and 7 picograms, respectively. This DMTe detection limit is the lowest reported to date for a volatile tellurium gas. A variety of selenium-resistant bacteria emitted mixtures of methylated sulfur/selenium gases when dosed with inorganic selenium salts in the presence of sulfur containing growth media. One of the gases detected was dimethyl selenenyl sulfide, CH_3SeSCH _3, reported here for the first time in headspace above microorganisms. In addition, this detector responded to reduced phosphorus compounds such as phosphine. The detection limit for this compound was 2.8 picograms. Detection limits for alkylated phosphines trimethyl and triethyl phosphine were 0.5 and 17 picograms respectively, based on the relative response of these compounds compared to dimethyl sulfide. This method can be used for the simultaneous determination of methylated sulfur, selenium, tellurium compounds found in biological systems. Part II of this dissertation describes work with methyldithiocarbhydrazide, a compound that has been synthesized for use as a derivatization reagent to capture formaldehyde in the gas phase. Chosen for its ability to react in a manner similar to 2,4-dinitrophenylhydrazine, this molecule was selected based on two structural characteristics: a hydrazine tag to react with and thereby capture carbonyls and a methyl sulfide group to allow for sensitive detection by fluorine-induced chemiluminescence. Although in the final analysis methyldithiocarbohydrazide failed as a successful means by which formaldehyde can be determined using gas chromatography in conjunction with fluorine-induced chemiluminescence, it did successfully derivatize formaldehyde in both solution and the gas phase without the need for low pH conditions.

  4. Extraction and determination of biogenic amines in fermented sausages and other meat products using reversed-phase-HPLC.

    PubMed

    Straub, B; Schollenberger, M; Kicherer, M; Luckas, B; Hammes, W P

    1993-09-01

    A convenient method is described for the analysis of biogenic amines (BA) by means of reversed-phase-HPLC. The method is characterized by multi-channel UV detection (diodearray), subsequent post-column derivatization with o-phthaldialdehyde and 3-mercaptopropionic acid, and fluorescence detection. For the analysis of meat products and especially fermented sausages an optimized perchloric acid extraction process was introduced to determine putrescine, cadaverine, histamine, tyramine and 2-phenylethylamine. BA recoveries from meat ranged between 96 and 113% with a detection limit for amines of 0.5 mg/kg.

  5. Anodic Stripping Voltammetry with Pencil Graphite Electrode for Determination of Chromium (III)

    NASA Astrophysics Data System (ADS)

    Wyantuti, S.; Hafidza, R. A.; Ishmayana, S.; Hartati, Y. W.

    2017-02-01

    Chromium is required as micronutrient that has roles in insulin metabolism and blood glucose level regulation. Chromium (III) deficiency can cause hyperglycemia and glycosuria. However, a high amount of chromium in body can cause allergic reaction, organ damage, and even death because of its toxicity. Chromium is commonly used in steel industries. Simultaneously with the development of industry, the waste disposal that can endanger environment also increased. Therefore, a sensitive and specific analysis method for chromium detection is required. Stripping voltammetry is one of the voltammetric methods that is commonly used for heavy metal analysis due to the very low limit of detection (sub ppb). The present study was conducted to develop an analysis method for chromium (III) determination using pencil graphite electrode. Quantitative determination was performed for chromium (III) which measured at -0.8 to +1.0 V with deposition time for 60 s and 50 mV/s scan rate. Stripping voltammetric analysis of chromium (III) using pencil graphite electrode gave linear range at 12.5 to 75 ppm with limit of detection of 0.31 ppm.

  6. Refined methodology for the determination of neonicotinoid pesticides and their metabolites in honey bees and bee products by liquid chromatography-tandem mass spectrometry (LC-MS/MS).

    PubMed

    Kamel, Alaa

    2010-05-26

    An analytical method was refined for the extraction and determination of neonicotinoid pesticide residues and their metabolites in honey bees and bee products. Samples were extracted with 2% triethylamine (TEA) in acetonitrile (ACN) followed by salting out, solid phase extraction (SPE) cleanup, and detection using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The method was validated in triplicate at three fortification concentrations in each matrix. Good recoveries were observed for most analytes and ranged between 70 and 120% with relative standard deviations between replicates of <20% in most cases. The method limits of detection were 0.2 ng/g for the parent neonicotinoid pesticides and ranged between 0.2 and 15 ng/g for the neonicotinoid metabolites. This refined method provides lower detection limits and improved recovery of neonicotinoids and their metabolites, which will help researchers evaluate subchronic effects of these pesticides, address data gaps related to colony collapse disorder (CCD), and determine the role of pesticides in pollinator decline.

  7. Automation of sample processing for ICP-MS determination of 90Sr radionuclide at ppq level for nuclear technology and environmental purposes.

    PubMed

    Kołacińska, Kamila; Chajduk, Ewelina; Dudek, Jakub; Samczyński, Zbigniew; Łokas, Edyta; Bojanowska-Czajka, Anna; Trojanowicz, Marek

    2017-07-01

    90 Sr is a widely determined radionuclide for environmental purposes, nuclear waste control, and can be also monitored in coolants in nuclear reactor plants. In the developed method, the ICP-MS detection was employed together with sample processing in sequential injection analysis (SIA) setup, equipped with a lab-on-valve with mechanized renewal of sorbent bed for solid-phase extraction. The optimized conditions of determination included preconcentration of 90 Sr on cation-exchange column and removal of different type of interferences using extraction Sr-resin. The limit of detection of the developed procedure depends essentially on the configuration of the employed ICP-MS spectrometer and on the available volume of the sample to be analyzed. For 1L initial sample volume, the method detection limit (MDL) value was evaluated as 2.9ppq (14.5BqL -1 ). The developed method was applied to analyze spiked river water samples, water reference materials, and also simulated and real samples of the nuclear reactor coolant. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Rapid Microcystin Determination Using a Paper Spray Ionization Method with a Time-of-Flight Mass Spectrometry System.

    PubMed

    Zhu, Xiaoqiang; Huang, Zhengxu; Gao, Wei; Li, Xue; Li, Lei; Zhu, Hui; Mo, Ting; Huang, Bao; Zhou, Zhen

    2016-07-13

    The eutrophication of surface water sources and climate changes have resulted in an annual explosion of cyanobacterial blooms in many irrigating and drinking water resources. To decrease health risks to the public, a rapid real time method for the synchronous determination of two usually harmful microcystins (MC-RR and MC-LR) in environmental water samples was built by employing a paper spray ionization method coupled with a time-of-flight mass spectrometer system. With this approach, direct analysis of microcystin mixtures without sample preparation has been achieved. Rapid detection was performed, simulating the release process of microcystins in reservoir water samples, and the routine detection frequency was every three minutes. The identification time of microcystins was reduced from several hours to a few minutes. The limit of detection is 1 μg/L, and the limit of quantitation is 3 μg/L. This method displays the ability for carrying out rapid, direct, and high-throughput experiments for determination of microcystins, and it would be of significant interest for environmental and food safety applications.

  9. [Determination of 3-monochloropropane-1,2-diol in grease food by solid phase extraction-derivatization-gas chromatography-mass spectrometry].

    PubMed

    Xiang, Xiaoling; Wang, Liyuan; Shen, Xianghong; Li, Chunsong; Shen, Jianfu; Wu, Pinggu

    2017-09-01

    To establish the method of determination of 3-monochloropropane-1,2-diol( 3-MCPD) in grease food by gas chromatography-mass spectrometry( GC-MS). 3-MCPD in grease food represented by bean paste was extracted by ultrasound,purified by alkaline earth solid phase extraction column,derivatived using phenylboronic acid( PBA) and detected by GC-MS. The linearity of 3-MCPD ranged from 1-100 ng/mL,with correlation coefficient at 0. 9993.The limits of quantitation( LOQ) in soy sauce,bean paste,pepper oil were 0. 6,0. 5 and7. 0 μg/kg and limits of detection( LOD) were 1. 9,1. 6 and 18. 8 μg/kg,respectively.Average recovery rate and relative standard deviation was 78. 3%-106. 7% and 1. 9%-11. 6%( n = 6), when 3-MCPD was added in grease food at 2. 5-1000 μg/kg. The method has good purification effect and the detection sensitivity and accuracy,and can be used for the determination of 3-MCPD in grease food.

  10. Analytical methods for multiresidue determination of sulfonamides and trimethoprim in meat and ground water samples by CE-MS and CE-MS/MS.

    PubMed

    Soto-Chinchilla, Jorge J; García-Campaña, Ana M; Gámiz-Gracia, Laura

    2007-11-01

    This paper presents two methods based on CZE-MS detection and CZE-MS/MS detection developed for the multiresidue determination of ten sulfonamides (sulfapyridine, sulfadoxin, sulfamethazine, sulfadimethoxine, sulfameter, sulfamerazine, sulfachlorpyridazine, sulfadiazine, sulfamethoxazole, and sulfamethizole) and a potentiator, trimethoprim (TMP), whose contents are regulated by the EU Council Regulation no. 2377/90 in animal edible tissues. Experimental designs were employed to optimize the electrospray conditions. MS/MS experiments using an IT as analyzer operating in multiple reaction monitoring (MRM) mode were carried out to achieve the minimum number of points according to the 2002/657/EC European Decision for unambiguous identification. The proposed procedures have been compared in terms of the performance characteristics and trueness. The limits of detection and quantification were in all cases lower than the maximum residue limits legislated for these compounds and the recoveries were satisfactory, being possible the application for their monitoring in foodstuff of animal origin and in environmental samples, allowing the determination of sulfonamides and TMP residues in meat and in superficial water in the low microg/L range.

  11. Repeatability Assessment by ISO 11843-7 in Quantitative HPLC for Herbal Medicines.

    PubMed

    Chen, Liangmian; Kotani, Akira; Hakamata, Hideki; Tsutsumi, Risa; Hayashi, Yuzuru; Wang, Zhimin; Kusu, Fumiyo

    2015-01-01

    We have proposed an assessment methods to estimate the measurement relative standard deviation (RSD) of chromatographic peaks in quantitative HPLC for herbal medicines by the methodology of ISO 11843 Part 7 (ISO 11843-7:2012), which provides detection limits stochastically. In quantitative HPLC with UV detection (HPLC-UV) of Scutellaria Radix for the determination of baicalin, the measurement RSD of baicalin by ISO 11843-7:2012 stochastically was within a 95% confidence interval of the statistically obtained RSD by repetitive measurements (n = 6). Thus, our findings show that it is applicable for estimating of the repeatability of HPLC-UV for determining baicalin without repeated measurements. In addition, the allowable limit of the "System repeatability" in "Liquid Chromatography" regulated in a pharmacopoeia can be obtained by the present assessment method. Moreover, the present assessment method was also successfully applied to estimate the measurement RSDs of quantitative three-channel liquid chromatography with electrochemical detection (LC-3ECD) of Chrysanthemi Flos for determining caffeoylquinic acids and flavonoids. By the present repeatability assessment method, reliable measurement RSD was obtained stochastically, and the experimental time was remarkably reduced.

  12. Optimized laser-induced breakdown spectroscopy for determination of xenobiotic silver in monosodium glutamate and its verification using ICP-AES.

    PubMed

    Rehan, I; Gondal, M A; Rehan, K

    2018-04-20

    Laser-induced breakdown spectroscopy (LIBS) was applied as a potential tool for the determination of xenobiotic metal in monosodium glutamate (MSG). In order to achieve a high-sensitivity LIBS system required to determine trace amounts of metallic silver in MSG and to attain the best detection limit, the parameters used in our experiment (impact of focusing laser energy on the intensity of LIBS emission signals, the influence of focusing lens distance on the intensity of LIBS signals, and time responses of the plasma emissions) were optimized. The spectra of MSG were obtained in air using a suitable detector with an optical resolution of 0.06 nm, covering a spectral region from 220 to 720 nm. Along with the detection of xenobiotic silver, other elements such as Ca, Mg, S, and Na were also detected in MSG. To determine the concentration of xenobiotic silver in MSG, the calibration curve was plotted by preparing standard samples having different silver abundances in an MSG matrix. The LIBS results of each sample were cross-verified by analyzing with a standard analytical technique such as inductively coupled plasma-atomic emission spectroscopy (ICP-AES). Both (LIBS and ICP-AES) results were in mutual agreement. The limit of detection of the LIBS setup was found to be 0.57 ppm for silver present in MSG samples.

  13. Self-calibrating multiplexer circuit

    DOEpatents

    Wahl, Chris P.

    1997-01-01

    A time domain multiplexer system with automatic determination of acceptable multiplexer output limits, error determination, or correction is comprised of a time domain multiplexer, a computer, a constant current source capable of at least three distinct current levels, and two series resistances employed for calibration and testing. A two point linear calibration curve defining acceptable multiplexer voltage limits may be defined by the computer by determining the voltage output of the multiplexer to very accurately known input signals developed from predetermined current levels across the series resistances. Drift in the multiplexer may be detected by the computer when the output voltage limits, expected during normal operation, are exceeded, or the relationship defined by the calibration curve is invalidated.

  14. High-throughput method for the determination of residues of β-lactam antibiotics in bovine milk by LC-MS/MS.

    PubMed

    Jank, Louise; Martins, Magda Targa; Arsand, Juliana Bazzan; Hoff, Rodrigo Barcellos; Barreto, Fabiano; Pizzolato, Tânia Mara

    2015-01-01

    This study describes the development and validation procedures for scope extension of a method for the determination of β-lactam antibiotic residues (ampicillin, amoxicillin, penicillin G, penicillin V, oxacillin, cloxacillin, dicloxacillin, nafcillin, ceftiofur, cefquinome, cefoperazone, cephapirine, cefalexin and cephalonium) in bovine milk. Sample preparation was performed by liquid-liquid extraction (LLE) followed by two clean-up steps, including low temperature purification (LTP) and a solid phase dispersion clean-up. Extracts were analysed using a liquid chromatography-electrospray-tandem mass spectrometry system (LC-ESI-MS/MS). Chromatographic separation was performed in a C18 column, using methanol and water (both with 0.1% of formic acid) as mobile phase. Method validation was performed according to the criteria of Commission Decision 2002/657/EC. Main validation parameters such as linearity, limit of detection, decision limit (CCα), detection capability (CCβ), accuracy, and repeatability were determined and were shown to be adequate. The method was applied to real samples (more than 250) and two milk samples had levels above maximum residues limits (MRLs) for cloxacillin - CLX and cefapirin - CFAP.

  15. Sensitive spectrofluorimetric determination of tizanidine in pharmaceutical preparations, human plasma and urine through derivatization with dansyl chloride.

    PubMed

    Ulu, Sevgi Tatar

    2012-01-01

    A sensitive spectrofluorimetric method was developed for the determination of tizanidine in human plasma, urine and pharmaceutical preparations. The method is based on reaction of tizanidine with 1-dimethylaminonaphthalene-5-sulphonyl chloride (dansyl chloride) in an alkaline medium to form a highly fluorescent derivative that was measured at 511 nm after excitation at 383 nm. The different experimental parameters affecting the fluorescence intensity of tizanidine was carefully studied and optimized. The fluorescence-concentration plots were rectilinear over the ranges 50-500 and 20-300 ng/mL for plasma and urine, respectively, detection limits of 1.81 and 0.54 ng/mL and quantification limits of 5.43 and 1.62 ng/mL for plasma and urine, respectively. The method presents good performance in terms of linearity, detection and quantification limits, precision, accuracy and specificity. The proposed method was successfully applied for the determination of tizanidine in pharmaceutical preparations. The results obtained were compared with a reference method, using t- and F-tests. Copyright © 2011 John Wiley & Sons, Ltd.

  16. Determination of β-blockers in pharmaceutical and human urine by capillary electrophoresis with electrochemiluminescence detection and studies on the pharmacokinetics.

    PubMed

    Wang, Yuanchao; Wu, Qiong; Cheng, Meirong; Cai, Cheng

    2011-04-15

    A novel method for simultaneous determination of atenolol, metoprolol and esmolol was proposed by capillary electrophoresis (CE) separation and electrochemiluminescence (ECL) detection. Poly-β-cyclodextrin (Poly-β-CD) was used as an additive in the running buffer to improve the separation of three analytes. The conditions for CE separation, ECL detection and effect of Poly-β-CD were investigated in detail. The three β-blockers with very similar structures were well separated and detected under the optimum conditions. The linear ranges of the standard solution for atenolol and esmolol were 2.5-125 μmol/L with a detection limit (S/N=3) of 0.5 μmol/L, and for metoprolol was 0.5-25 μmol/L with a detection limit of 0.1 μmol/L. For three β-blockers from spiked aqueous and urine samples, the accuracy and precision including intraday and interday experiments were performed by calculating the recovery, the relative standard deviations of the ECL intensity and the migration time, respectively. The developed method was applied to the determination of metoprolol content in commercial pharmaceutical, and the analytical results are in good agreement with the nominal value with recoveries in the range of 98.7-105%. The proposed method was also applied to the monitoring of pharmacokinetics for metoprolol in human body. Crown Copyright © 2011. Published by Elsevier B.V. All rights reserved.

  17. Sensitive determination of tilmicosin, erythromycin ethylsuccinate and clindamycin by CE with electrochemiluminescence detection using azithromycin as internal standard and its applications.

    PubMed

    Liu, Yan-Ming; Shi, Yan-Mei; Liu, Zhuan-Li; Peng, Long-Fei

    2010-05-01

    A sensitive approach for the simultaneous determination of tilmicosin, erythromycin ethylsuccinate and clindamycin was developed by CE coupled with electrochemiluminescence detection with ionic liquid. The parameters for CE, electrochemiluminescence detection and the effect of ionic liquid were investigated systematically. The three analytes were well separated and detected within 8 min. The limits of detection (S/N=3) of tilmicosin, erythromycin ethylsuccinate and clindamycin are 3.4x10(-9), 2.3x10(-8) and 1.3x10(-8) mol/L, respectively. The precisions (RSD%) of the peak area and the migration time are from 0.8 to 1.5% and from 0.2 to 0.5% within a day and from 1.8 to 2.7% and from 0.6 to 0.8% in 3 days, respectively. The limits of quantitation (S/N=10) of tilmicosin, erythromycin ethylsuccinate and clindamycin are 3.2x10(-8), 2.9x10(-7) and 9.1x10(-8) mol/L in human urines and 5.5x10(-8), 3.2x10(-7) and 2.1x10(-7) mol/L in milk samples, respectively. The recoveries of three analytes at different concentration levels in urine, milk and drugs are between 90.0 and 104.7%. The proposed method was successfully applied to the determination of three analytes in human urine, milk and drugs.

  18. Improved method for the on-line metal chelate affinity chromatography-high-performance liquid chromatographic determination of tetracycline antibiotics in animal products.

    PubMed

    Cooper, A D; Stubbings, G W; Kelly, M; Tarbin, J A; Farrington, W H; Shearer, G

    1998-07-03

    An improved on-line metal chelate affinity chromatography-high-performance liquid chromatography (MCAC-HPLC) method for the determination of tetracycline antibiotics in animal tissues and egg has been developed. Extraction was carried out with ethyl acetate. The extract was then evaporated to dryness and reconstituted in methanol prior to on-line MCAC clean-up and HPLC-UV determination. Recoveries of tetracycline, oxytetracycline, demeclocycline and chlortetracycline in the range 42% to 101% were obtained from egg, poultry, fish and venison tissues spiked at 25 micrograms kg-1. Limits of detection less than 10 microgram kg-1 were estimated for all four analytes. This method has higher throughput, higher recovery and lower limits of detection than a previously reported on-line MCAC-HPLC method which involved aqueous extraction and solid-phase extraction clean-up.

  19. High-performance liquid chromatographic assay for the determination of Aloe Emodin in mouse plasma.

    PubMed

    Zaffaroni, M; Mucignat, C; Pecere, T; Zagotto, G; Frapolli, R; D'Incalci, M; Zucchetti, M

    2003-10-25

    An isocratic high-performance liquid chromatography (HPLC) method was developed and validated to determine Aloe Emodin (AE) in mouse plasma. The analysis required 0.3 ml of plasma and involves extraction with dichloromethane. The HPLC separation was carried out on Symmetry Shield RP18, a mobile phase of methanol-water-acetic acid (65:35:0.2) and fluorescence detection at lambda(ex)=410 nm and lambda(em)=510 nm. The retention time of AE was 11.7 min. The assay was linear from 10 to 1,000 ng/ml (r2 > or = 0.999), showed intra- and inter-day precision within 7.8 and 4.7%, and accuracy of 87.3-105.7%. Detection limit (LOD) and quantification limit (LOQ) were 4.5 and 5 ng/ml, respectively. The method was applied to determine for the first time the pharmacokinetic of AE in mice.

  20. [Determination of trace gallium by graphite furnace atomic absorption spectrometry in urine].

    PubMed

    Zhou, L Z; Fu, S; Gao, S Q; He, G W

    2016-06-20

    To establish a method for determination trace gallium in urine by graphite furnace atomic absorption spectrometry (GFAAS). The ammonium dihydrogen phosphate was matrix modifier. The temperature effect about pyrolysis (Tpyr) and atomization temperature were optimized for determination of trace gallium. The method of technical standard about within-run, between-run and recoveries of standard were optimized. The method showed a linear relationship within the range of 0.20~80.00 μg/L (r=0.998). The within-run and between-run relative standard deviations (RSD) of repetitive measurement at 5.0, 10.0, 20.0 μg/L concentration levels were 2.1%~5.5% and 2.3%~3.0%. The detection limit was 0.06 μg/L. The recoveries of gallium were 98.2%~101.1%. This method is simple, low detection limit, accurate, reliable and reproducible. It has been applied for determination of trace gallium in urine samples those who need occupation health examination or poisoning diagnosis.

  1. Highly sensitive determination of iron (III) ion based on phenanthroline probe: Surface-enhanced Raman spectroscopy methods

    NASA Astrophysics Data System (ADS)

    Chen, Lei; Ma, Ning; Park, Yeonju; Jin, Sila; Hwang, Hoon; Jiang, Dayu; Jung, Young Mee

    2018-05-01

    In this paper, we introduced Raman spectroscopy techniques that were based on the traditional Fe3 + determination method with phenanthroline as a probe. Interestingly, surface-enhanced Raman spectroscopy (SERS)-based approach exhibited excellent sensitivities to phenanthroline. Different detection mechanisms were observed for the RR and SERS techniques, in which the RR intensity increased with increasing Fe3 + concentration due to the observation of the RR effect of the phenanthroline-Fe2 + complex, whereas the SERS intensity increased with decreasing Fe3 + concentration due to the observation of the SERS effect of the uncomplexed phenanthroline. More importantly, the determination sensitivity was substantially improved in the presence of a SERS-active substrate, giving a detection limit as low as 0.001 μg/mL, which is 20 times lower than the limit of the UV-vis and RR methods. Furthermore, the proposed SERS method was free from other ions interference and can be used quality and sensitivity for the determination of the city tap water.

  2. Highly selective and sensitive determination of Cu2+ in drink and water samples based on a 1,8-diaminonaphthalene derived fluorescent sensor

    NASA Astrophysics Data System (ADS)

    Sun, Tao; Li, Yang; Niu, Qingfen; Li, Tianduo; Liu, Yan

    2018-04-01

    A new simple and efficient fluorescent sensor L based on 1,8-diaminonaphthalene Schiff-base for highly sensitive and selective determination of Cu2+ in drink and water has been developed. This Cu2+-selective detection over other tested metal ions displayed an obvious color change from blue to colorless easily detected by naked eye. The detection limit is determined to be as low as 13.2 nM and the response time is very fast within 30 s. The 1:1 binding mechanism was well confirmed by fluorescence measurements, IR analysis and DFT calculations. Importantly, this sensor L was employed for quick detection of Cu2+ in drink and environmental water samples with satisfactory results, providing a simple, rapid, reliable and feasible Cu2+-sensing method.

  3. Evaluation of a single-item screening question to detect limited health literacy in peritoneal dialysis patients.

    PubMed

    Jain, Deepika; Sheth, Heena; Bender, Filitsa H; Weisbord, Steven D; Green, Jamie A

    2014-01-01

    Studies have shown that a single-item question might be useful in identifying patients with limited health literacy. However, the utility of the approach has not been studied in patients receiving maintenance peritoneal dialysis (PD). We assessed health literacy in a cohort of 31 PD patients by administering the Rapid Estimate of Adult Literacy in Medicine (REALM) and a single-item health literacy (SHL) screening question "How confident are you filling out medical forms by yourself?" (Extremely, Quite a bit, Somewhat, A little bit, or Not at all). To determine the accuracy of the single-item question for detecting limited health literacy, we performed sensitivity and specificity analyses of the SHL and plotted the area under the receiver operating characteristic (AUROC) curve using the REALM as a reference standard. Using a cut-off of "Somewhat" or less confident, the sensitivity of the SHL for detecting limited health literacy was 80%, and the specificity was 88%. The positive likelihood ratio was 6.9. The SHL had an AUROC of 0.79 (95% confidence interval: 0.52 to 1.00). Our results show that the SHL could be effective in detecting limited health literacy in PD patients.

  4. Determination of phenolic compounds and hydroxymethylfurfural in meads using high performance liquid chromatography with coulometric-array and UV detection.

    PubMed

    Kahoun, David; Rezková, Sona; Veskrnová, Katerina; Královský, Josef; Holcapek, Michal

    2008-08-15

    The objective of this study was the determination of 25 phenolic compounds in different mead samples (honeywines) using high performance liquid chromatography (HPLC) with coulometric-array detection and in case of hydroxymethylfurfural with UV detection. Our method was optimized in respect to both the separation selectivity of individual phenolic compounds and the maximum sensitivity with the electrochemical detection. The method development included the optimization of mobile phase composition, the pH value, conditions of the gradient elution and the flow rate using a window-diagram approach. The developed method was used for the determination of limits of detection and limits of quantitation for individual compounds. The linearity of calibration curves, accuracy and precision (intra- and inter-day) at three concentration levels (low, middle and high concentration range) were verified. Mead samples were diluted with the mobile phase at 1:1 to 1:50 ratio depending on the concentration and filtered through a PTFE filter without any other sample pre-treatment. Phenolic compounds concentration was determined in 50 real samples of meads and correlated with meads composition and hydroxymethylfurfural concentration. The most frequently occurred compounds were protocatechuic acid and vanillic acid (both of them were present in 98% samples), the least occurred compounds were (+)-catechin (10% samples) and sinapic acid (12% samples). Vanillin and ethylvanillin, which are used as artificial additives for the taste improvement, were found in 60% and 42% samples, respectively. Hydroxymethylfurfural concentration, as an indicator of honey quality, was in the range from 2.47 to 158 mg/L. Our method is applicable for the determination of 25 phenolic compounds in mead, honey and related natural samples.

  5. An adaptive confidence limit for periodic non-steady conditions fault detection

    NASA Astrophysics Data System (ADS)

    Wang, Tianzhen; Wu, Hao; Ni, Mengqi; Zhang, Milu; Dong, Jingjing; Benbouzid, Mohamed El Hachemi; Hu, Xiong

    2016-05-01

    System monitoring has become a major concern in batch process due to the fact that failure rate in non-steady conditions is much higher than in steady ones. A series of approaches based on PCA have already solved problems such as data dimensionality reduction, multivariable decorrelation, and processing non-changing signal. However, if the data follows non-Gaussian distribution or the variables contain some signal changes, the above approaches are not applicable. To deal with these concerns and to enhance performance in multiperiod data processing, this paper proposes a fault detection method using adaptive confidence limit (ACL) in periodic non-steady conditions. The proposed ACL method achieves four main enhancements: Longitudinal-Standardization could convert non-Gaussian sampling data to Gaussian ones; the multiperiod PCA algorithm could reduce dimensionality, remove correlation, and improve the monitoring accuracy; the adaptive confidence limit could detect faults under non-steady conditions; the fault sections determination procedure could select the appropriate parameter of the adaptive confidence limit. The achieved result analysis clearly shows that the proposed ACL method is superior to other fault detection approaches under periodic non-steady conditions.

  6. Comparison of two fabricated aptasensors based on modified carbon paste/oleic acid and magnetic bar carbon paste/Fe3O4@oleic acid nanoparticle electrodes for tetracycline detection.

    PubMed

    Jahanbani, Shahriar; Benvidi, Ali

    2016-11-15

    In this research, we have improved two aptasensors based on a modified carbon paste electrode (CPE) with oleic acid (OA), and a magnetic bar carbon paste electrode (MBCPE) with Fe3O4 magnetic nanoparticles and oleic acid (OA). After the immobilization process of anti-TET at the electrode surfaces, the aptasensors were named CPE/OA/anti-TET and MBCPE/Fe3O4NPs/OA/anti-TET respectively. In this paper, the detection of tetracycline is compared using CPE/OA/anti-TET and MBCPE/Fe3O4NPs/OA/anti-TET aptasensors. These modified electrodes were characterized by infrared spectroscopy (IR), scanning electron microscopy (SEM), electrochemical impedance spectroscopy (EIS), UV-vis spectroscopy, and voltammetric methods. The linear range and the detection limit for TET with the CPE/OA/anti-TET aptasensor were found to be 1.0×10(-12)-1.0×10(-7)M and 3.0×10(-13)M respectively by EIS method. The linear range and the detection limit for TET with the CPE/OA/anti-TET aptasensor were found to be 1.0×10(-10)-1.0×10(-7)M with a limit of detection of 2.9×10(-11)M using differential pulse voltammetry (DPV) technique. The MBCPE/Fe3O4NPs/OA/anti-TET aptasensor was used for determination of TET, and a liner range of 1.0×10(-14)-1.0×10(-6)M with a detection limit of 3.8×10(-15)M was obtained by EIS method. Also, the linear range and detection limit of 1.0×10(-12)-1.0×10(-6)M and 3.1×10(-13)M respectively, were obtained for MBCPE/Fe3O4NPs/OA/anti-TET aptasensor using DPV. The proposed aptasensors were applied for determination of tetracycline in some real samples such as drug, milk, honey and blood serum samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Determination of acrylamide and methacrylamide by normal phase high performance liquid chromatography and UV detection.

    PubMed

    Paleologos, E K; Kontominas, M G

    2005-06-10

    A method using normal phase high performance liquid chromatography (NP-HPLC) with UV detection was developed for the analysis of acrylamide and methacrylamide. The method relies on the chromatographic separation of these analytes on a polar HPLC column designed for the separation of organic acids. Identification of acrylamide and methacrylamide is approached dually, that is directly in their protonated forms and as their hydrolysis products acrylic and methacrylic acid respectively, for confirmation. Detection and quantification is performed at 200 nm. The method is simple allowing for clear resolution of the target peaks from any interfering substances. Detection limits of 10 microg L(-1) were obtained for both analytes with the inter- and intra-day RSD for standard analysis lying below 1.0%. Use of acetonitrile in the elution solvent lowers detection limits and retention times, without impairing resolution of peaks. The method was applied for the determination of acrylamide and methacrylamide in spiked food samples without native acrylamide yielding recoveries between 95 and 103%. Finally, commercial samples of french and roasted fries, cookies, cocoa and coffee were analyzed to assess applicability of the method towards acrylamide, giving results similar with those reported in the literature.

  8. Evaluation of spectrophotometric and HPLC methods for shikimic acid determination in plants: models in glyphosate-resistant and -susceptible crops.

    PubMed

    Zelaya, Ian A; Anderson, Jennifer A H; Owen, Micheal D K; Landes, Reid D

    2011-03-23

    Endogenous shikimic acid determinations are routinely used to assess the efficacy of glyphosate in plants. Numerous analytical methods exist in the public domain for the detection of shikimic acid, yet the most commonly cited comprise spectrophotometric and high-pressure liquid chromatography (HPLC) methods. This paper compares an HPLC and two spectrophotometric methods (Spec 1 and Spec 2) and assesses the effectiveness in the detection of shikimic acid in the tissues of glyphosate-treated plants. Furthermore, the study evaluates the versatility of two acid-based shikimic acid extraction methods and assesses the longevity of plant extract samples under different storage conditions. Finally, Spec 1 and Spec 2 are further characterized with respect to (1) the capacity to discern between shikimic acid and chemically related alicyclic hydroxy acids, (2) the stability of the chromophore (t1/2), (3) the detection limits, and (4) the cost and simplicity of undertaking the analytical procedure. Overall, spectrophotometric methods were more cost-effective and simpler to execute yet provided a narrower detection limit compared to HPLC. All three methods were specific to shikimic acid and detected the compound in the tissues of glyphosate-susceptible crops, increasing exponentially in concentration within 24 h of glyphosate application and plateauing at approximately 72 h. Spec 1 estimated more shikimic acid in identical plant extract samples compared to Spec 2 and, likewise, HPLC detection was more effective than spectrophotometric determinations. Given the unprecedented global adoption of glyphosate-resistant crops and concomitant use of glyphosate, an effective and accurate assessment of glyphosate efficacy is important. Endogenous shikimic acid determinations are instrumental in corroborating the efficacy of glyphosate and therefore have numerous applications in herbicide research and related areas of science as well as resolving many commercial issues as a consequence of glyphosate utilization.

  9. Detection of Microbial Water Quality Indicators and Fecal Waterborne Pathogens in Environmental Waters: A Review of Methods, Applications, and Limitations

    EPA Science Inventory

    Environmental waters are important reservoirs of pathogenic microorganisms, many of which are of fecal origin. In most cases, the presence of pathogens is determined using surrogate bacterial indicators. In other cases, direct detection of the pathogen in question is required. M...

  10. Potentiometric detection in UPLC as an easy alternative to determine cocaine in biological samples.

    PubMed

    Daems, Devin; van Nuijs, Alexander L N; Covaci, Adrian; Hamidi-Asl, Ezat; Van Camp, Guy; Nagels, Luc J

    2015-07-01

    The analytical methods which are often used for the determination of cocaine in complex biological matrices are a prescreening immunoassay and confirmation by chromatography combined with mass spectrometry. We suggest an ultra-high-pressure liquid chromatography combined with a potentiometric detector, as a fast and practical method to detect and quantify cocaine in biological samples. An adsorption/desorption model was used to investigate the usefulness of the potentiometric detector to determine cocaine in complex matrices. Detection limits of 6.3 ng mL(-1) were obtained in plasma and urine, which is below the maximum residue limit (MRL) of 25 ng mL(-1). A set of seven plasma samples and 10 urine samples were classified identically by both methods as exceeding the MRL or being inferior to it. The results obtained with the UPLC/potentiometric detection method were compared with the results obtained with the UPLC/MS method for samples spiked with varying cocaine concentrations. The intraclass correlation coefficient was 0.997 for serum (n =7) and 0.977 for urine (n =8). As liquid chromatography is an established technique, and as potentiometry is very simple and cost-effective in terms of equipment, we believe that this method is potentially easy, inexpensive, fast and reliable. Copyright © 2014 John Wiley & Sons, Ltd.

  11. Determination of Zinc, Cadmium, Lead, Copper and Silver Using a Carbon Paste Electrode and a Screen Printed Electrode Modified with Chromium(III) Oxide

    PubMed Central

    Koudelkova, Zuzana; Syrovy, Tomas; Ambrozova, Pavlina; Moravec, Zdenek; Kubac, Lubomir; Hynek, David; Adam, Vojtech

    2017-01-01

    In this study, the preparation and electrochemical application of a chromium(III) oxide modified carbon paste electrode (Cr-CPE) and a screen printed electrode (SPE), made from the same material and optimized for the simple, cheap and sensitive simultaneous determination of zinc, cadmium, lead, copper and the detection of silver ions, is described. The limits of detection and quantification were 25 and 80 µg·L−1 for Zn(II), 3 and 10 µg·L−1 for Cd(II), 3 and 10 µg·L−1 for Pb(II), 3 and 10 µg·L−1 for Cu(II), and 3 and 10 µg·L−1 for Ag(I), respectively. Furthermore, this promising modification was transferred to the screen-printed electrode. The limits of detection for the simultaneous determination of zinc, cadmium, copper and lead on the screen printed electrodes were found to be 350 µg·L−1 for Zn(II), 25 µg·L−1 for Cd(II), 3 µg·L−1 for Pb(II) and 3 µg·L−1 for Cu(II). Practical usability for the simultaneous detection of these heavy metal ions by the Cr-CPE was also demonstrated in the analyses of wastewaters. PMID:28792450

  12. Determination of Zinc, Cadmium, Lead, Copper and Silver Using a Carbon Paste Electrode and a Screen Printed Electrode Modified with Chromium(III) Oxide.

    PubMed

    Koudelkova, Zuzana; Syrovy, Tomas; Ambrozova, Pavlina; Moravec, Zdenek; Kubac, Lubomir; Hynek, David; Richtera, Lukas; Adam, Vojtech

    2017-08-09

    In this study, the preparation and electrochemical application of a chromium(III) oxide modified carbon paste electrode (Cr-CPE) and a screen printed electrode (SPE), made from the same material and optimized for the simple, cheap and sensitive simultaneous determination of zinc, cadmium, lead, copper and the detection of silver ions, is described. The limits of detection and quantification were 25 and 80 µg·L -1 for Zn(II), 3 and 10 µg·L -1 for Cd(II), 3 and 10 µg·L -1 for Pb(II), 3 and 10 µg·L -1 for Cu(II), and 3 and 10 µg·L -1 for Ag(I), respectively. Furthermore, this promising modification was transferred to the screen-printed electrode. The limits of detection for the simultaneous determination of zinc, cadmium, copper and lead on the screen printed electrodes were found to be 350 µg·L -1 for Zn(II), 25 µg·L -1 for Cd(II), 3 µg·L -1 for Pb(II) and 3 µg·L -1 for Cu(II). Practical usability for the simultaneous detection of these heavy metal ions by the Cr-CPE was also demonstrated in the analyses of wastewaters.

  13. A sensitive and rapid determination of ranitidine in human plasma by HPLC with fluorescence detection and its application for a pharmacokinetic study.

    PubMed

    Ulu, Sevgi Tatar; Tuncel, Muzaffer

    2012-04-01

    A novel precolumn derivatization reversed-phase high-performance liquid chromatography method with fluorescence detection is described for the determination of ranitidine in human plasma. The method was based on the reaction of ranitidine with 4-fluoro-7-nitrobenzo-2-oxa-1,3-diazole forming yellow colored fluorescent product. The separation was achieved on a C(18) column using methanol-water (60:40, v/v) mobile phase. Fluorescence detection was used at the excitation and emission of 458 and 521 nm, respectively. Lisinopril was utilized as an internal standard. The flow rate was 1.2 mL/min. Ranitidine and lisinopril appeared at 3.24 and 2.25 min, respectively. The method was validated for system suitability, precision, accuracy, linearity, limit of detection, limit of quantification, recovery and robustness. Intra- and inter-day precisions of the assays were in the range of 0.01-0.44%. The assay was linear over the concentration range of 50-2000 ng/mL. The mean recovery was determined to be 96.40 ± 0.02%. This method was successfully applied to a pharmacokinetic study after oral administration of a dose (150 mg) of ranitidine. © The Author [2012]. Published by Oxford University Press. All rights reserved.

  14. Electrochemical characterization of repaglinide and its determination in human plasma using liquid chromatography with dual-channel coulometric detection.

    PubMed

    Jirovský, David; Bartošová, Zdenka; Skopalová, Jana; Maier, Vítezslav

    2010-12-01

    A simple, fast and sensitive HPLC method employing dual-channel coulometric detection for the determination of repaglinide in human plasma is presented. The assay involved extraction of repaglinide by ethyl acetate and isocratic reversed-phase liquid chromatography with dual-channel coulometric detection. The mobile phase composition was 50mM disodium hydrogen phosphate/acetonitrile (60:40, v/v), pH of the mobile phase 7.5 set up with phosphoric acid. For all analyses, the first cell working potential was +380mV, the second was +750mV (vs. Pd/H(2)). Calibration curve was linear over the concentration range of 5-500nmolL(-1). Rosiglitazone was used as an internal standard. The limit of detection (LOD) was established at 2.8nmolL(-1), and the lower limit of quantification (LLOQ) at 8.5nmolL(-1). The developed method was applied to human plasma samples spiked with repaglinide at therapeutical concentrations. It was confirmed that the method is suitable for pharmacokinetic studies or therapeutic monitoring. Copyright © 2010 Elsevier B.V. All rights reserved.

  15. Signal-to-noise ratios in coherent soft limiters

    NASA Technical Reports Server (NTRS)

    Lesh, J. R.

    1973-01-01

    Expressions for the output signal-to-noise power ratio of a bandpass soft limiter followed by a coherent detection device are presented and discussed. It is found that a significant improvement in the output signal-to-noise ratio at low input SNRs can be achieved by such soft limiters as compared to hard limiters. This indicates that the soft limiter may be of some use in the area of threshold extension. Approximation methods for determining output signal-to-noise spectral densities are also presented.

  16. Reflotron cholesterol measurement in general practice: accuracy and detection of errors.

    PubMed

    Ball, M J; Robertson, I K; Woods, M

    1994-11-01

    Comparison of cholesterol determinations by nurses using a Reflotron analyser in a general practice setting showed a good correlation with plasma cholesterol determinations by wet chemistry in a clinical biochemistry laboratory. A limited number of comparisons did, however, give a much lower result on the Reflotron. In an experimental situation, small sample volumes (which could result from poor technique) were shown to produce falsely low readings. A simple method which may immediately detect falsely low Reflotron readings is discussed.

  17. Photothermal trace detection in capillary electrophoresis for biomedical diagnostics and toxic materials (invited)

    NASA Astrophysics Data System (ADS)

    Faubel, Werner; Heissler, Stefan; Pyell, Ute; Ragozina, Natalia

    2003-01-01

    Two applications of a near-field thermal lens capillary electrophoresis detector in the deep ultraviolet region (pump beam 257 nm wavelength) will be presented: (1) Capillary electrophoretic determination of the pharmaceuticals Tramadol, Verapamil, and Papaverin. Direct separation techniques were used for the different classes of substances with characteristic absorbance spectra. The combination of capillary electrophoresis and the highly sensitive detection with thermal lens spectroscopy permits the analysis of nanoliter volume samples common in biomedical diagnostics without any preconcentration step. (2) The determination of (nonfluorescent) nitro aromatic explosives in contaminated soil. These compounds are detected with the laboratory built thermal lens detector after their separation by micellar electrokinetic chromatography. Its shown that this type of detection makes it possible to obtain limits of detection 1-2 orders of magnitude lower than those obtained with classical absorption spectrometric detection.

  18. [Immunoaffinity columns and determination of ochratoxin A in cereals by HPLC. Part I.: Evaluation of extraction using methanol/water].

    PubMed

    Czerwiecki, Ludwik; Czyzyk, Kamila; Kwiecień, Agnieszka; Wilczyńska, Grazyna

    2004-01-01

    The method for ochratoxin A determination in cereals (wheat, rye) was described. Application of immunoaffinity columns (IAC) for clean-up of extracts was investigated. The ochratoxin A content was determined by high-performance liquid chromatography using C18 column and fluorimetric detection at 330 nm (excitation) and 460 nm (emission). The mean recovery of ochratoxin A was 65-78%. The limits of detection (LOD) and quantification (LOQ) were 0.015 and 0.025 microg/kg, respectively. The positive results were confirmed by reaction with BF3 complex in methanol.

  19. Evaluation of PCR Approaches for Detection of Bartonella bacilliformis in Blood Samples.

    PubMed

    Gomes, Cláudia; Martinez-Puchol, Sandra; Pons, Maria J; Bazán, Jorge; Tinco, Carmen; del Valle, Juana; Ruiz, Joaquim

    2016-03-01

    The lack of an effective diagnostic tool for Carrion's disease leads to misdiagnosis, wrong treatments and perpetuation of asymptomatic carriers living in endemic areas. Conventional PCR approaches have been reported as a diagnostic technique. However, the detection limit of these techniques is not clear as well as if its usefulness in low bacteriemia cases. The aim of this study was to evaluate the detection limit of 3 PCR approaches. We determined the detection limit of 3 different PCR approaches: Bartonella-specific 16S rRNA, fla and its genes. We also evaluated the viability of dry blood spots to be used as a sample transport system. Our results show that 16S rRNA PCR is the approach with a lowest detection limit, 5 CFU/μL, and thus, the best diagnostic PCR tool studied. Dry blood spots diminish the sensitivity of the assay. From the tested PCRs, the 16S rRNA PCR-approach is the best to be used in the direct blood detection of acute cases of Carrion's disease. However its use in samples from dry blood spots results in easier management of transport samples in rural areas, a slight decrease in the sensitivity was observed. The usefulness to detect by PCR the presence of low-bacteriemic or asymptomatic carriers is doubtful, showing the need to search for new more sensible techniques.

  20. Presence and distribution of nitrate and selected pesticides in surficial-sand aquifers and selected lakes, 1983-94, East Otter Tail County, Minnesota

    USGS Publications Warehouse

    Smith, Shannon E.; Ruhl, James E.

    1995-01-01

    Lake water was sampled from 11 sites on Little Pine, Big Pine, Rush, and Otter Tail Lakes. Nitrate-nitrogen concentrations were all below the detection limit (0.05 mg/L). The concentration of triazine herbicide compounds, as determined by immunoassay, was at or below the detection limit (0.10 ug/L) at all 11 sites. Dissolved oxygen concentrations at the sites ranged from 7.3 to 10.1 mg/L at the water surface, and from 5.3 to 9.7 mg/L at depth. Secchi disk transparency readings ranged from 4.0 to 7.4 feet. Total phosphorus concentrations were generally near or below the detection limit (0.01 mg/L) except at one site where the water had a total phosphorus concentration of 0.06 mg/L.

  1. Analysis of nuclear resonance fluorescence excitation measured with LaBr3(Ce) detectors near 2 MeV

    NASA Astrophysics Data System (ADS)

    Omer, Mohamed; Negm, Hani; Ohgaki, Hideaki; Daito, Izuru; Hayakawa, Takehito; Bakr, Mahmoud; Zen, Heishun; Hori, Toshitada; Kii, Toshiteru; Masuda, Kai; Hajima, Ryoichi; Shizuma, Toshiyuki; Toyokawa, Hiroyuki; Kikuzawa, Nobuhiro

    2013-11-01

    The performance of LaBr3(Ce) to measure nuclear resonance fluorescence (NRF) excitations is discussed in terms of limits of detection and in comparison with high-purity germanium (HPGe) detectors near the 2 MeV region where many NRF excitation levels from special nuclear materials are located. The NRF experiment was performed at the High Intensity γ-ray Source (HIγS) facility. The incident γ-rays, of 2.12 MeV energy, hit a B4C target to excite the 11B nuclei to the first excitation level. The statistical-sensitive non-linear peak clipping (SNIP) algorithm was implemented to eliminate the background and enhance the limits of detection for the spectra measured with LaBr3(Ce). Both detection and determination limits were deduced from the experimental data.

  2. Determining TOC in Waters

    ERIC Educational Resources Information Center

    Kehoe, Thomas J.

    1977-01-01

    The instrumental method for detecting total organic carbon (TOC) in water samples is detailed. The method's limitations are discussed and certain precautions that must be taken are emphasized. The subject of TOC versus COD and BOD is investigated and TOC is determined to be a valid indication of biological demand. (BT)

  3. Simultaneous square-wave voltammetric determination of aspartame and cyclamate using a boron-doped diamond electrode.

    PubMed

    Medeiros, Roberta Antigo; de Carvalho, Adriana Evaristo; Rocha-Filho, Romeu C; Fatibello-Filho, Orlando

    2008-07-30

    A simple and highly selective electrochemical method was developed for the simultaneous determination of aspartame and cyclamate in dietary products at a boron-doped diamond (BDD) electrode. In square-wave voltammetric (SWV) measurements, the BDD electrode was able to separate the oxidation peak potentials of aspartame and cyclamate present in binary mixtures by about 400 mV. The detection limit for aspartame in the presence of 3.0x10(-4) mol L(-1) cyclamate was 4.7x10(-7) mol L(-1), and the detection limit for cyclamate in the presence of 1.0x10(-4) mol L(-1) aspartame was 4.2x10(-6) mol L(-1). When simultaneously changing the concentration of both aspartame and cyclamate in a 0.5 mol L(-1) sulfuric acid solution, the corresponding detection limits were 3.5x10(-7) and 4.5x10(-6) mol L(-1), respectively. The relative standard deviation (R.S.D.) obtained was 1.3% for the 1.0x10(-4) mol L(-1) aspartame solution (n=5) and 1.1% for the 3.0x10(-3) mol L(-1) cyclamate solution. The proposed method was successfully applied in the determination of aspartame in several dietary products with results similar to those obtained using an HPLC method at 95% confidence level.

  4. Determination of cocaine, benzoylecgonine, cocaethylene and norcocaine in human hair using solid-phase extraction and liquid chromatography with tandem mass spectrometric detection.

    PubMed

    Moore, Christine; Coulter, Cynthia; Crompton, Katherine

    2007-11-15

    A quantitative analytical procedure for the determination of cocaine, benzoylecgonine and cocaethylene and norcocaine in hair has been developed and validated. The hair samples were washed, incubated, and any drugs present were quantified using mixed mode solid-phase extraction and liquid chromatography with tandem mass spectrometric detection in positive atmospheric pressure chemical ionization mode. For confirmation, two transitions were monitored and one ion ratio was determined, which was within 20% of that of the known calibration standards. The monitoring of the qualifying transition and requirement for its presence within a specific ratio to the primary ion limited the sensitivity of the assay, particularly for benzoylecgonine, however, the additional confidence in the final result as well as forensic defensibility were considered to be of greater importance. Even with simultaneous monitoring, the concentrations proposed by the United States Federal guidelines for hair analysis were achieved. The limits of quantitation were 50 pg/mg; the limit of detection was 25 pg/mg. The intra-day precision of the assays at 100 pg/mg (n=5) was 1.3%, 8.1%, 0.8% and 0.4%; inter-day precision 4.8%, 9.2%, 15.7% and 12.6% (n=10) for cocaine, benzoylecgonine, cocaethylene and norcocaine, respectively. The methods were applied to both proficiency specimens and to samples obtained during research studies in the USA.

  5. Utilization of Photochemically Induced Fluorescence Detection for HPLC Determination of Genotoxic Impurities in the Vortioxetine Manufacturing Process.

    PubMed

    Douša, Michal; Doubský, Jan; Srbek, Jan

    2016-07-01

    An analytical reversed-phase high-performance liquid chromatography (HPLC) method for the detection and quantitative determination of two genotoxic impurities at ppm level present in the vortioxetine manufacturing process is described. Applying the concept of threshold of toxicological concern, a limit of 75 ppm each for both genotoxic impurities was calculated based on the maximum daily dose of active pharmaceutical ingredients. The novel reversed-phase HPLC method with photochemically induced fluorescence detection was developed on XSELECT Charged Surface Hybrid Phenyl-Hexyl column using the mobile phase consisted a mixture of 10 mM ammonium formate pH 3.0 and acetonitrile. The elution was performed using an isocratic composition of 48:52 (v/v) at a flow rate of 1.0 mL/min. The photochemically induced fluorescence detection is based on the use of UV irradiation at 254 nm through measuring the fluorescence intensity at 300 nm and an excitation wavelength of 272 nm to produce fluorescent derivatives of both genotoxic impurities. The online photochemical conversion and detection is easily accomplished for two expected genotoxic impurities and provides a sufficiently low limit detection and quantification for the target analysis. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  6. Rapid Detection of Melamine in Tap Water and Milk Using Conjugated "One-Step" Molecularly Imprinted Polymers-Surface Enhanced Raman Spectroscopic Sensor.

    PubMed

    Hu, Yaxi; Lu, Xiaonan

    2016-05-01

    An innovative "one-step" sensor conjugating molecularly imprinted polymers and surface enhanced Raman spectroscopic-active substrate (MIPs-SERS) was investigated for simultaneous extraction and determination of melamine in tap water and milk. This sensor was fabricated by integrating silver nanoparticles (AgNPs) with MIPs synthesized by bulk polymerization of melamine (template), methacrylic acid (functional monomer), ethylene glycol dimethacrylate (cross-linking agent), and 2,2'-azobisisobutyronitrile (initiator). Static and kinetic adsorption tests validated the specific affinity of MIPs-AgNPs to melamine and the rapid adsorption equilibration rate. Principal component analysis segregated SERS spectral features of tap water and milk samples with different melamine concentrations. Partial least squares regression models correlated melamine concentrations in tap water and skim milk with SERS spectral features. The limit of detection (LOD) and limit of quantification (LOQ) of melamine in tap water were determined as 0.0019 and 0.0064 mmol/L, while the LOD and LOQ were 0.0165 and 0.055 mmol/L for the determination of melamine in skim milk. However, this sensor is not ideal to quantify melamine in tap water and skim milk. By conjugating MIPs with SERS-active substrate (that is, AgNPs), reproducibility of SERS spectral features was increased, resulting in more accurate detection. The time required to determine melamine in tap water and milk were 6 and 25 min, respectively. The low LOD, LOQ, and rapid detection confirm the potential of applying this sensor for accurate and high-throughput detection of melamine in tap water and milk. © 2016 Institute of Food Technologists®

  7. Performance of blue-yellow screening test for antimicrobial detection in ovine milk.

    PubMed

    Linage, B; Gonzalo, C; Carriedo, J A; Asensio, J A; Blanco, M A; De La Fuente, L F; San Primitivo, F

    2007-12-01

    Drug residues in milk are important because of public health and industrial implications. The detection limits of 25 antimicrobial agents were determined by the blue-yellow screening method in ovine milk. For each drug, 8 concentrations were tested on 20 ovine milk samples from individual ewes in midlactation. Detection limits determined by means of logistic regression were below European Union maximum residue limits (EU-MRL) for penicillin G (3 to 4 microg/kg), ceftiofur (96 to 107 microg/kg), framycetin (720 to 781 microg/kg), neomycin (915 to 1,084 microg/kg), and tylosin (44 to 51 microg/kg). Detection limits for ampicillin (5 to 6 microg/kg), cloxacillin (33 to 42 microg/kg), cefoperazone (73 to 82 microg/kg), cefalexin (160 to 202 microg/kg), gentamycin (355 to 382 microg/kg), streptomycin (3,063 to 3,593 microg/kg), tilmicosin (109 to 131 microg/kg), erythromycin (444 to 522 microg/kg), spyramicin (1,106 to 1,346 microg/kg), sulfadimethoxine (101 to 119 microg/kg), sulfathiazole (122 to 151 microg/kg), sulfamethazine (309 to 328 microg/kg), sulfanilamide (1,750 to 2,674 microg/kg), tetracycline (233 to 257 microg/kg), oxytetracycline (398 to 501 microg/kg), doxycycline (323 to 419 microg/kg), chlortetracycline (3,331 to 3,989 microg/kg), danofloxacin (4.7 to 5.5 mg/kg), enrofloxacin (41 to 46 mg/kg), and flumequin (63 to 71 mg/kg) were higher than the EU-MRL. Although the blue-yellow method showed improved sensitivity compared with other tests studied in ovine milk, the performance of screening methods for detecting antimicrobial agents in milk of this species should be improved.

  8. Validation of a LC-fluorescence method for determination of free captopril in human plasma, using a pre-column derivatization reaction with monobromobimane.

    PubMed

    Tache, Florentin; Farca, Alexandru; Medvedovici, Andrei; David, Victor

    2002-05-15

    Both derivatization of free captopril in human plasma samples using monobromobimane as fluorescent label and the corresponding HPLC-fluorescence detection (FLD) method were validated. Calibration curve for the fluorescent captopril derivative in plasma samples is linear in the ppb-ppm range with a detection limit of 4 ppb and an identification limit of 10 ppb (P%: 90; nu > or = 5). These methods were successfully applied on bioequivalence studies carried out on some marketed pharmaceutical formulations.

  9. Electrical leakage detection circuit

    DOEpatents

    Wild, Arthur

    2006-09-05

    A method is provided for detecting electrical leakage between a power supply and a frame of a vehicle or machine. The disclosed method includes coupling a first capacitor between a frame and a first terminal of a power supply for a predetermined period of time. The current flowing between the frame and the first capacitor is limited to a predetermined current limit. It is determined whether the voltage across the first capacitor exceeds a threshold voltage. A first output signal is provided when the voltage across the capacitor exceeds the threshold voltage.

  10. Determination of methyl mercury by aqueous phase Eehylation, followed by gas chromatographic separation with cold vapor atomic fluorescence detection

    USGS Publications Warehouse

    De Wild, John F.; Olsen, Mark L.; Olund, Shane D.

    2002-01-01

    A recent national sampling of streams in the United States revealed low methyl mercury concentrations in surface waters. The resulting median and mean concentrations, calculated from 104 samples, were 0.06 nanograms per liter (ng/L) and 0.15 ng/L, respectively. This level of methyl mercury in surface water in the United States has created a need for analytical techniques capable of detecting sub-nanogram per liter concentrations. In an attempt to create a U.S. Geological Survey approved method, the Wisconsin District Mercury Laboratory has adapted a distillation/ethylation/ gas-phase separation method with cold vapor atomic fluorescence spectroscopy detection for the determination of methyl mercury in filtered and unfiltered waters. This method is described in this report. Based on multiple analyses of surface water and ground-water samples, a method detection limit of 0.04 ng/L was established. Precision and accuracy were evaluated for the method using both spiked and unspiked ground-water and surface-water samples. The percent relative standard deviations ranged from 10.2 to 15.6 for all analyses at all concentrations. Average recoveries obtained for the spiked matrices ranged from 88.8 to 117 percent. The precision and accuracy ranges are within the acceptable method-performance limits. Considering the demonstrated detection limit, precision, and accuracy, the method is an effective means to quantify methyl mercury in waters at or below environmentally relevant concentrations

  11. Electrochemical Microsensors for the Detection of Cadmium(II) and Lead(II) Ions in Plants

    PubMed Central

    Krystofova, Olga; Trnkova, Libuse; Adam, Vojtech; Zehnalek, Josef; Hubalek, Jaromir; Babula, Petr; Kizek, Rene

    2010-01-01

    Routine determination of trace metals in complex media is still a difficult task for many analytical instruments. The aim of this work was to compare three electro-chemical instruments [a standard potentiostat (Autolab), a commercially available miniaturized potentiostat (PalmSens) and a homemade micropotentiostat] for easy-to-use and sensitive determination of cadmium(II) and lead(II) ions. The lowest detection limits (hundreds of pM) for both metals was achieved by using of the standard potentiostat, followed by the miniaturized potentiostat (tens of nM) and the homemade instrument (hundreds of nM). Nevertheless, all potentiostats were sensitive enough to evaluate contamination of the environment, because the environmental limits for both metals are higher than detection limits of the instruments. Further, we tested all used potentiostats and working electrodes on analysis of environmental samples (rainwater, flour and plant extract) with artificially added cadmium(II) and lead(II). Based on the similar results obtained for all potentiostats we choose a homemade instrument with a carbon tip working electrode for our subsequent environmental experiments, in which we analyzed maize and sunflower seedlings and rainwater obtained from various sites in the Czech Republic. PMID:22219663

  12. Size-exclusion chromatography for the determination of the boiling point distribution of high-boiling petroleum fractions.

    PubMed

    Boczkaj, Grzegorz; Przyjazny, Andrzej; Kamiński, Marian

    2015-03-01

    The paper describes a new procedure for the determination of boiling point distribution of high-boiling petroleum fractions using size-exclusion chromatography with refractive index detection. Thus far, the determination of boiling range distribution by chromatography has been accomplished using simulated distillation with gas chromatography with flame ionization detection. This study revealed that in spite of substantial differences in the separation mechanism and the detection mode, the size-exclusion chromatography technique yields similar results for the determination of boiling point distribution compared with simulated distillation and novel empty column gas chromatography. The developed procedure using size-exclusion chromatography has a substantial applicability, especially for the determination of exact final boiling point values for high-boiling mixtures, for which a standard high-temperature simulated distillation would have to be used. In this case, the precision of final boiling point determination is low due to the high final temperatures of the gas chromatograph oven and an insufficient thermal stability of both the gas chromatography stationary phase and the sample. Additionally, the use of high-performance liquid chromatography detectors more sensitive than refractive index detection allows a lower detection limit for high-molar-mass aromatic compounds, and thus increases the sensitivity of final boiling point determination. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Spectrofluorimetric determination of tobramycin in human serum and pharmaceutical preparations by derivatization with fluorescamine.

    PubMed

    Tekkeli, Serife Evrim Kepekci; Önal, Armağan; Sağırlı, A Olcay

    2014-02-01

    A simple, sensitive and selective spectrofluorimetric method has been developed for the determination of tobramycin (TOB) in human serum and pharmaceutical preparations. The method is based on the reaction between the primary amino group of TOB and fluorescamine in borate buffer, pH 8.5, to give a highly fluorescent derivative which is measured at 469 nm after excitation at 388 nm. The fluorescence intensity was directly proportional to the concentration over the range 300-1500 ng/mL, with a limit of detection of 65 ng/mL and limit of quantitation of 215 ng/mL. All variables were investigated to optimize the reaction conditions. The method was validated according to International Conference on Harmonization guidelines in terms of specificity, linearity, limit of detection, limit of quantification, accuracy, precision and robustness. Good recoveries were obtained ranging from 97.4 to 100.64%, indicating that no interference was observed from concomitants usually present in pharmaceutical dosage forms. The method was successfully, applied for the analysis of the drug substance in its pharmaceutical preparations and spiked serum samples. Copyright © 2013 John Wiley & Sons, Ltd.

  14. Automated exploitation of sky polarization imagery.

    PubMed

    Sadjadi, Firooz A; Chun, Cornell S L

    2018-03-10

    We propose an automated method for detecting neutral points in the sunlit sky. Until now, detecting these singularities has been done manually. Results are presented that document the application of this method on a limited number of polarimetric images of the sky captured with a camera and rotating polarizer. The results are significant because a method for automatically detecting the neutral points may aid in the determination of the solar position when the sun is obscured and may have applications in meteorology and pollution detection and characterization.

  15. Detection limit of Mycobacterium chimaera in water samples for monitoring medical device safety: insights from a pilot experimental series.

    PubMed

    Schreiber, P W; Köhler, N; Cervera, R; Hasse, B; Sax, H; Keller, P M

    2018-07-01

    A growing number of Mycobacterium chimaera infections after cardiosurgery have been reported by several countries. These potentially fatal infections were traced back to contaminated heater-cooler devices (HCDs), which use water as a heat transfer medium. Aerosolization of water contaminated with M. chimaera from HCDs enables airborne transmission to patients undergoing open chest surgery. Infection control teams test HCD water samples for mycobacterial growth to guide preventive measures. The detection limit of M. chimaera in water samples, however, has not previously been investigated. To determine the detection limit of M. chimaera in water samples using laboratory-based serial dilution tests. An M. chimaera strain representative of the international cardiosurgery-associated M. chimaera outbreak was used to generate a logarithmic dilution series. Two different water volumes, 50 and 1000mL, were inoculated, and, after identical processing (centrifugation, decantation, and decontamination), seeded on mycobacteria growth indicator tube (MGIT) and Middlebrook 7H11 solid media. MGIT consistently showed a lower detection limit than 7H11 solid media, corresponding to a detection limit of ≥1.44 × 10 4 cfu/mL for 50mL and ≥2.4cfu/mL for 1000mL water samples. Solid media failed to detect M. chimaera in 50mL water samples. Depending on water volume and culture method, major differences exist in the detection limit of M. chimaera. In terms of sensitivity, 1000mL water samples in MGIT media performed best. Our results have important implications for infection prevention and control strategies in mitigation of the M. chimaera outbreak and healthcare water safety in general. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  16. Quantitative surface-enhanced resonance Raman scattering of phthalocyanine-labelled oligonucleotides

    PubMed Central

    Macaskill, A.; Chernonosov, A. A.; Koval, V. V.; Lukyanets, E. A.; Fedorova, O. S.; Smith, W. E.; Faulds, K.; Graham, D.

    2007-01-01

    The evaluation of phthalocyanine labels for the surface-enhanced resonance Raman scattering (SERRS) detection of oligonucleotides is reported. Three phthalocyanine-labelled oligonucleotides were assessed, each containing a different metal centre. Detection limits for each labelled oligonucleotide were determined using two excitation frequencies where possible. Limits of detection as low as 2.8 × 10−11 mol. dm−3 were obtained which are comparable to standard fluorescently labelled probes used in previous SERRS studies. The identification of two phthalocyanine-labelled oligonucleotides without separation was also demonstrated indicating their suitability for multiplexing. This study extends the range of labels suitable for quantitative surface-enhanced resonance Raman scattering with silver nanoparticles and offers more flexibility and choice when considering SERRS for quantitative DNA detection. PMID:17289751

  17. The determination of levofloxacin by flow injection analysis using UV detection, potentiometry, and conductometry in pharmaceutical preparations.

    PubMed

    Altiokka, G; Atkosar, Z; Can, N O

    2002-10-15

    A flow injection analysis (FIA) using UV detection, potentiometry and conductometry for levofloxacin (LVF) are described in this study. The best solvent system was found to consist of 0.2 M acetate buffer at pH 3 having 10% MeOH. A flow rate of 1 ml min(-1) was pumped and active material was detected at 288 nm. The detection limit (LOD) and limit of quantification (LOQ) for FIA were calculated to be 3 x 10(-7) M (S/N = 3) and 1 x 10(-7) M (S/N = 10), respectively. In the analysis of tablets, the RSD values were found to be 0.83, 0.98 and 0.99 for FIA, potentiometric and conductometric methods, respectively. Copyright 2002 Elsevier Science B.V.

  18. Aptamer-based potentiometric measurements of proteins using ion-selective microelectrodes.

    PubMed

    Numnuam, Apon; Chumbimuni-Torres, Karin Y; Xiang, Yun; Bash, Ralph; Thavarungkul, Panote; Kanatharana, Proespichaya; Pretsch, Ernö; Wang, Joseph; Bakker, Eric

    2008-02-01

    We here report on the first example of an aptamer-based potentiometric sandwich assay of proteins. The measurements are based on CdS quantum dot labels of the secondary aptamer, which were determined with a novel solid-contact Cd2+-selective polymer membrane electrode after dissolution with hydrogen peroxide. The electrode exhibited cadmium ion detection limits of 100 pM in 100 mL samples and of 1 nM in 200 microL microwells, using a calcium-selective electrode as a pseudoreference electrode. As a prototype example, thrombin was measured in 200 microL samples with a lower detection limit of 0.14 nM corresponding to 28 fmol of analyte. The results show great promise for the potentiometric determination of proteins at very low concentrations in microliter samples.

  19. Bioelectrocatalytic application of titania nanotube array for molecule detection.

    PubMed

    Xie, Yibing; Zhou, Limin; Huang, Haitao

    2007-06-15

    A bioelectrocatalysis system based on titania nanotube electrode has been developed for the quantitative detection application. Highly ordered titania nanotube array with inner diameter of 60 nm and total length of 540 nm was formed by anodizing titanium foils. The functionalization modification was achieved by embedding glucose oxidases inside tubule channels and electropolymerizing pyrrole for interfacial immobilization. Morphology and microstructure characterization, electrochemical properties and bioelectrocatalytic reactivities of this composite were fully investigated. The direct detection of hydrogen peroxide by electrocatalytic reduction reaction was fulfilled on pure titania nanotube array with a detection limit up to 2.0 x 10(-4)mM. A biosensor based on the glucose oxidase-titania/titanium electrode was constructed for amperometric detection and quantitative determination of glucose in a phosphate buffer solution (pH 6.8) under a potentiostatic condition (-0.4V versus SCE). The resulting glucose biosensor showed an excellent performance with a response time below 5.6s and a detection limit of 2.0 x 10(-3)mM. The corresponding detection sensitivity was 45.5 microA mM(-1)cm(-2). A good operational reliability was also achieved with relative standard deviations below 3.0%. This novel biosensor exhibited quite high response sensitivity and low detection limit for potential applications.

  20. Methods of analysis by the U.S. Geological Survey National Water Quality Laboratory; determination of chlorinated pesticides in aquatic tissue by capillary-column gas chromatography with electron-capture detection

    USGS Publications Warehouse

    Leiker, Thomas J.; Madsen, J.E.; Deacon, J.R.; Foreman, W.T.

    1995-01-01

    A method for the determination of chlorinated organic compounds in aquatic tissue by dual capillary-column gas chromatography with electron-capture detection is described. Whole-body-fish or corbicula tissue is homogenized, Soxhlet extracted, lipid removed by gel permeation chromatography, and fractionated using alumina/silica adsorption chromatography. The extracts are analyzed by dissimilar capillary-column gas chromatography with electron-capture detection. The method reporting limits are 5 micrograms per kilogram (μg/kg) for chlorinated compounds, 50 μg/kg for polychlorinated biphenyls, and 200 μg/kg for toxaphene.

  1. Validity and Reliability of a Virtual Reality Game in Evaluating the Projected Frontal Plane Knee Angle When Landing From a Drop Vertical Jump.

    PubMed

    Mills, Kathryn; Idris, Aula; Pham, Thu-An; Porte, John; Wiggins, Mark; Kavakli, Manolya

    2017-12-18

    To determine the validity and reliability of the peak frontal plane knee angle evaluated by a virtual reality (VR) netball game when landing from a drop vertical jump (DVJ). Laboratory Methods: Forty participants performed 3 DVJs evaluated by 3-dimensional (3D) motion analysis and 3 DVJs evaluated by the VR game. Limits of agreement for the peak projected frontal plane knee angle and peak knee abduction were determined. Participants were given a consensus category of "Above threshold" or "Below threshold" based on a pre-specified threshold angle of 9˚ during landing. Classification agreement was determined using kappa coefficient and accuracy was determined using specificity and sensitivity. Ten participants returned 1-week later to determine intra-rater reliability, standard error of the measure and typical error. The mean difference in detected frontal plane knee angle was 3.39˚ (1.03˚, 5.74˚). Limits of agreement were -10.27˚ (-14.36˚, -6.19˚) to 17.05˚ (12.97˚, 21.14˚). Substantial agreement, specificity and sensitivity were observed for the threshold classification (ĸ = 0.66, [0.42, 0.88] specificity= 0.96 [0.78, 1.0], sensitivity= 0.75 [0.43, 0.95]). The game exhibited acceptable reliability over time (ICC (3,1) = 0.844) and error was approximately 2˚. The VR game reliably evaluated a projected frontal plane knee angle. While the knee angle detected by the VR game is strongly related peak knee abduction, the accuracy of detecting the exact angle was limited. A threshold approach may be a more accurate approach for gaming technology to evaluate frontal plane knee angles when landing from a jump.

  2. Purgeable organic compounds at or near the Idaho Nuclear Technology and Engineering Center, Idaho National Laboratory, Idaho, 2015

    USGS Publications Warehouse

    Maimer, Neil V.; Bartholomay, Roy C.

    2016-05-25

    During 2015, the U.S. Geological Survey, in cooperation with the U.S. Department of Energy, collected groundwater samples from 31 wells at or near the Idaho Nuclear Technology and Engineering Center (INTEC) at the Idaho National Laboratory for purgeable organic compounds (POCs). The samples were collected and analyzed for the purpose of evaluating whether purge water from wells located inside an areal polygon established downgradient of the INTEC must be treated as a Resource Conservation and Recovery Act listed waste.POC concentrations in water samples from 29 of 31 wells completed in the eastern Snake River Plain aquifer were greater than their detection limit, determined from detection and quantitation calculation software, for at least one to four POCs. Of the 29 wells with concentrations greater than their detection limits, only 20 had concentrations greater than the laboratory reporting limit as calculated with detection and quantitation calculation software. None of the concentrations exceeded any maximum contaminant levels established for public drinking water supplies. Most commonly detected compounds were 1,1,1-trichoroethane, 1,1-dichloroethene, and trichloroethene.

  3. Simultaneous determination of ethyl carbamate and urea in Korean rice wine by ultra-performance liquid chromatography coupled with mass spectrometric detection.

    PubMed

    Lee, Gyeong-Hweon; Bang, Dae-Young; Lim, Jung-Hoon; Yoon, Seok-Min; Yea, Myeong-Jai; Chi, Young-Min

    2017-10-15

    In this study, a rapid method for simultaneous detection of ethyl carbamate (EC) and urea in Korean rice wine was developed. To achieve quantitative analysis of EC and urea, the conditions for Ultra-performance liquid chromatography (UPLC) separation and atmospheric-pressure chemical ionization tandem mass spectrometry (APCI-MS/MS) detection were first optimized. Under the established conditions, the detection limit, relative standard deviation and linear range were 2.83μg/L, 3.75-5.96%, and 0.01-10.0mg/L, respectively, for urea; the corresponding values were 0.17μg/L, 1.06-4.01%, and 1.0-50.0μg/L, respectively, for EC. The correlation between the contents of EC and its precursor urea was determined under specific pH (3.5 and 4.5) and temperature (4, 25, and 50°C) conditions using the developed method. As a result, EC content was increased with greater temperature and lower pH. In Korean rice wine, urea was detected 0.19-1.37mg/L and EC was detected 2.0-7.7μg/L. The method developed in this study, which has the advantages of simplified sample preparation, low detection limits, and good selectivity, was successfully applied for the rapid analysis of EC and urea. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Automated system for on-line determination of dimethylarsinic and inorganic arsenic by hydride generation-atomic fluorescence spectrometry.

    PubMed

    Chaparro, L L; Ferrer, L; Cerdà, V; Leal, L O

    2012-09-01

    A multisyringe flow-injection approach has been coupled to hydride generation-atomic fluorescence spectrometry (HG-AFS) with UV photo-oxidation for dimethylarsinic (DMA), inorganic As and total As determination, depending on the pre-treatment given to the sample (extraction or digestion). The implementation of a UV lamp allows on-line photo-oxidation of DMA and the following arsenic detection, whereas a bypass leads the flow directly to the HG-AFS system, performing inorganic arsenic determination. DMA concentration is calculated by the difference of total inorganic arsenic and measurement of the photo-oxidation step. The detection limits for DMA and inorganic arsenic were 0.09 and 0.47 μg L(-1), respectively. The repeatability values accomplished were of 2.4 and 1.8%, whereas the injection frequencies were 24 and 28 injections per hour for DMA and inorganic arsenic, respectively. This method was validated by means of a solid reference material BCR-627 (muscle of tuna) with good agreement with the certified values. Satisfactory results for DMA and inorganic arsenic determination were obtained in several water matrices. The proposed method offers several advantages, such as increasing the sampling frequency, low detection limits and decreasing reagents and sample consumption, which leads to lower waste generation.

  5. [The occurrence of Fusarium varieties and their mycotoxins on silo corn. 1. A method for the determination of zearalenone in corn and corn silage by high performance liquid chromatography (HPLC) with fluorescence detection].

    PubMed

    Lepom, P

    1988-09-01

    A method for the determination of zearalenone in maize and maize silage was developed which distinguishes itself by the effective and fast cleaning of the extracts with the help of a silica gel minicolumn. The samples were extracted with chloroform/methanol (9 + 1) and cleaned on a silica gel minicolumn after acid-base partition. The zearalenone was quantitatively determined optionally by means of high-performance liquid chromatography (HPLC) with fluorescence detection (excitation wavelength 236 nm, emission filter 418 nm) or thin-layer chromatography (TLC), p-methoxybenzene diazonium fluoroborate and aluminium chloride were used as detection chemicals. The limits of detection are 0.01 mg/kg (HPLC) and 0.1 mg/kg resp. (TLC), the average recovery is 81%. The method was used for the determination of zearalenone in grain maize, CCM silage and silage from whole maize plants.

  6. Photoacoustic Effect of Ethene: Sound Generation due to Plant Hormone Gases.

    NASA Astrophysics Data System (ADS)

    Park, Han Jung; Ide, David; University of Tennessee at Chattanooga Team

    2017-01-01

    Ethene, which is produced in plants as they mature, was used to study its photoacoustic properties using photoacoustic spectroscopy. Detection of trace amounts, with N2 gas, of the ethylene gas were also applied. The gas was tested in various conditions: temperature, concentration of the gas, gas cell length, and power of the laser, were varied to determine their effect on the photoacoustic signal, the ideal conditions to detect trace gas amounts, and concentration of ethylene produced by an avocado and banana. A detection limit of 10 ppm was determined for pure C2H4. A detection of 5% and 13% (by volume) concentration of ethylene were produced for a ripening avocado and banana, respectively, in closed space.

  7. Apricot DNA as an indicator for persipan: detection and quantitation in marzipan using ligation-dependent probe amplification.

    PubMed

    Luber, Florian; Demmel, Anja; Hosken, Anne; Busch, Ulrich; Engel, Karl-Heinz

    2012-06-13

    The confectionery ingredient marzipan is exclusively prepared from almond kernels and sugar. The potential use of apricot kernels, so-called persipan, is an important issue for the quality assessment of marzipan. Therefore, a ligation-dependent probe amplification (LPA) assay was developed that enables a specific and sensitive detection of apricot DNA, as an indicator for the presence of persipan. The limit of detection was determined to be 0.1% persipan in marzipan. The suitability of the method was confirmed by the analysis of 20 commercially available food samples. The integration of a Prunus -specific probe in the LPA assay as a reference allowed for the relative quantitation of persipan in marzipan. The limit of quantitation was determined to be 0.5% persipan in marzipan. The analysis of two self-prepared mixtures of marzipan and persipan demonstrated the applicability of the quantitation method at concentration levels of practical relevance for quality control.

  8. [Determination of inorganic ions in explosive residues by capillary zone electrophoresis].

    PubMed

    Feng, Junhe; Guo, Baoyuan; Lin, Jin-Ming; Xu, Jianzhong; Zhou, Hong; Sun, Yuyou; Liu, Yao; Quan, Yangke; Lu, Xiaoming

    2008-11-01

    Five anions (chlorate, perchlorate, nitrate, nitrite, and sulfate) and two cations (ammonium and potassium) in explosive residues have been separated and determined by capillary zone electrophoresis (CZE) with indirect ultraviolet detection. The electrolyte buffer for the cation separation was 10 mmol/L pyridine (pH 4.5) -3 mmol/L 18-crown-6-ether. Ammonium and potassium ions were baseline separated in less than 2.6 min with the detection limits of 0.10 mg/L and 0.25 mg/L (S/N = 3), respectively. The electrolyte buffer for the anion separation consisted of 40 mmol/L boric acid-1.8 mmol/L potassium dichromate-2 mmol/L sodium tetraborate (pH 8.6), and tetramethyl ammonium hydroxide (TMAOH) was used as electroosmotic flow modifier. All five anions were well separated in less than 4.6 min with the detection limit range of 0.10 - 1.85 mg/L (S/N = 3). The method was successfully used in real sample investigations to confirm the type of explosives.

  9. Evaluation of Total Nitrite Pattern Visualization as an Improved Method for Gunshot Residue Detection and its Application to Casework Samples.

    PubMed

    Berger, Jason; Upton, Colin; Springer, Elyah

    2018-04-23

    Visualization of nitrite residues is essential in gunshot distance determination. Current protocols for the detection of nitrites include, among other tests, the Modified Griess Test (MGT). This method is limited as nitrite residues are unstable in the environment and limited to partially burned gunpowder. Previous research demonstrated the ability of alkaline hydrolysis to convert nitrates to nitrites, allowing visualization of unburned gunpowder particles using the MGT. This is referred to as Total Nitrite Pattern Visualization (TNV). TNV techniques were modified and a study conducted to streamline the procedure outlined in the literature to maximize the efficacy of the TNV in casework, while reducing the required time from 1 h to 5 min, and enhancing effectiveness on blood-soiled samples. The TNV method was found to provide significant improvement in the ability to detect significant nitrite residues, without sacrificing efficiency, that would allow for the determination of the muzzle-to-target distance. © 2018 American Academy of Forensic Sciences.

  10. Detection of adulterated commercial Spanish beeswax.

    PubMed

    Serra Bonvehi, J; Orantes Bermejo, F J

    2012-05-01

    The physical and chemical parameters (melting point and saponification number), and the fraction of hydrocarbons, monoesters, acids and alcohols have been determined in 90 samples of Spanish commercial beeswax from Apis mellifera L. The adulteration with paraffins of different melting point, cow tallow, stearic acid, and carnauba wax were determined by HTGC-FID/MS detection, and the research was focussed mainly on paraffins and microcrystallines waxes. In general, the added adulterant can be identified by the presence of non-naturally beeswax components, and by the differences of values of selected components between pure and adulterated beeswax. The detection limits were determined using pure and adulterated beeswax with different amounts of added waxes (5%, 10%, 20% and 30%). Percentages higher than 1-5% of each adulterant can be detected in the mixtures. Paraffin waxes were confirmed in 33 of the 90 samples analysed at concentrations between 5% and 30%. Copyright © 2011 Elsevier Ltd. All rights reserved.

  11. An enzymatic method for determination of azide and cyanide in aqueous phase.

    PubMed

    Wan, Nan-Wei; Liu, Zhi-Qiang; Xue, Feng; Zheng, Yu-Guo

    2015-11-20

    A halohydrin dehalogenase (HHDH-PL) from Parvibaculum lavamentivorans DS-1 was characterized and applied to determine azide and cyanide in the water. In this methodology, HHDH-PL catalysed azide and cyanide to react with butylene oxide and form corresponding β-substituted alcohols 1-azidobutan-2-ol (ABO) and 3-hydroxypentanenitrile (HPN) that could be quantitatively detected by gas chromatograph. The detection calibration curves for azide (R(2)=0.997) and cyanide (R(2)=0.995) were linear and the lower limits of detection for azide and cyanide were 0.1 and 0.3mM, respectively. Several other nucleophiles were identified having no effect on the analysis of azide and cyanide, excepting nitrite which influenced the detection of cyanide. This was the first report of a biological method to determine the inorganic azide and cyanide by converting them to the measurable organics. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Piezoelectric detection of ion pairs between sulphonate and catecholamines for flow injection analysis of pharmaceutical preparations.

    PubMed

    Mo, Z; Long, X; Zhang, M

    1999-03-01

    Fundamentals of ion-pair flow injection with piezoelectric detection were investigated experimentally and theoretically for the adsorption of dodecyl phenylsulfonate and interfacial ion-pair formation with epinephrine and l-dopa on silver electrode of quartz crystal microbalance. The influences of sulfonate concentration and operating parameters on the frequency response were demonstrated and provided the possibility for the discriminating determination of mixtures. The selected system of ion-pair flow injection with piezoelectric detection was applied to the determination of epinephrine and l-dopa. Calibration curves were linear in ranges 4.00-850 and 3.50-730 mug ml(-1), with detection limits of 1.22 and 1.05 mug ml(-1) and sampling frequencies of 120 samples h(-1), for epinephrine and l-dopa, respectively. The method has been satisfactorily applied to the determination of catecholamines in pharmaceutical preparations.

  13. Antidepressants detection and quantification in whole blood samples by GC-MS/MS, for forensic purposes.

    PubMed

    Truta, Liliana; Castro, André L; Tarelho, Sónia; Costa, Pedro; Sales, M Goreti F; Teixeira, Helena M

    2016-09-05

    Depression is among the most prevalent psychiatric disorders of our society, leading to an increase in antidepressant drug consumption that needs to be accurately determined in whole blood samples in Forensic Toxicology Laboratories. For this purpose, this work presents a new gas chromatography tandem mass spectrometry (GC-MS/MS) method targeting the simultaneous and rapid determination of 14 common Antidepressants in whole blood: 13 Antidepressants (amitriptyline, citalopram, clomipramine, dothiepin, fluoxetine, imipramine, mianserin, mirtazapine, nortryptiline, paroxetine, sertraline, trimipramine and venlafaxine) and 1 Metabolite (N-desmethylclomipramine). Solid-phase extraction was used prior to chromatographic separation. Chromatographic and MS/MS parameters were selected to improve sensitivity, peak resolution and unequivocal identification of the eluted analyte. The detection was performed on a triple quadrupole tandem MS in selected ion monitoring (SIM) mode in tandem, using electronic impact ionization. Clomipramine-D3 and trimipramine-D3 were used as deutered internal standards. The validation parameters included linearity, limits of detection, lower limit of quantification, selectivity/specificity, extraction efficiency, carry-over, precision and robustness, and followed internationally accepted guidelines. Limits of quantification and detection were lower than therapeutic and sub-therapeutic concentration ranges. Overall, the method offered good selectivity, robustness and quick response (<16min) for typical concentration ranges, both for therapeutic and lethal levels. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Applicability of direct total reflection X-ray fluorescence analysis for selenium determination in solutions related to environmental and geochemical studies

    NASA Astrophysics Data System (ADS)

    Marguí, E.; Floor, G. H.; Hidalgo, M.; Kregsamer, P.; Roman-Ross, G.; Streli, C.; Queralt, I.

    2010-12-01

    A significant amount of environmental studies related to selenium determination in different environmental compartments have been published in the last years due to the narrow range between the Se nutritious requirement as essential element and toxic effects upon exposure. However, the direct analysis of complex liquid samples like natural waters and extraction solutions presents significant problems related to the low Se concentrations and the complicated matrix of this type of samples. The goal of the present research was to study the applicability of direct TXRF analysis of different type of solutions commonly used in environmental and geochemical studies, confirm the absence or presence of matrix effects and evaluate the limits of detection and accuracy for Se determination in the different matrices. Good analytical results were obtained for the direct analysis of ground and rain water samples with limits of detection for Se two orders of magnitude lower than the permissible Se concentration in drinking waters ([Se] = 10 μg/L) according to the WHO. However, the Se detection limits for more complex liquid samples such as thermal waters and extraction solutions were in the μg/L range due to the presence of high contents of other elements present in the matrix (i.e., Br, Fe, Zn) or the high background of the TXRF spectrum that hamper the Se determination at trace levels. Our results give insight into the possibilities and drawbacks of direct TXRF analysis and to a certain extent the potential applications in the environmental and geochemical field.

  15. Detection of shigella in lettuce by the use of a rapid molecular assay with increased sensitivity

    PubMed Central

    Jiménez, Kenia Barrantes; McCoy², Clyde B.; Achí, Rosario

    2010-01-01

    A Multiplex Polymerase Chain Reaction (PCR) assay to be used as an alternative to the conventional culture method in detecting Shigella and enteroinvasive Escherichia coli (EIEC) virulence genes ipaH and ial in lettuce was developed. Efficacy and rapidity of the molecular method were determined as compared to the conventional culture. Lettuce samples were inoculated with different Shigella flexneri concentrations (from 10 CFU/ml to 107 CFU/ml). DNA was extracted directly from lettuce after inoculation (direct-PCR) and after an enrichment step (enrichment PCR). Multiplex PCR detection limit was 104CFU/ml, diagnostic sensitivity and specificity were 100% accurate. An internal amplification control (IAC) of 100 bp was used in order to avoid false negative results. This method produced results in 1 to 2 days while the conventional culture method required 5 to 6 days. Also, the culture method detection limit was 106 CFU/ml, diagnostic sensitivity was 53% and diagnostic specificity was 100%. In this study a Multiplex PCR method for detection of virulence genes in Shigella and EIEC was shown to be effective in terms of diagnostic sensitivity, detection limit and amount of time as compared to Shigella conventional culture. PMID:24031579

  16. Screening method for the determination of tetracyclines and fluoroquinolones in animal drinking water by liquid chromatography with diode array detector.

    PubMed

    Patyra, E; Kowalczyk, E; Grelik, A; Przeniosło-Siwczyńska, M; Kwiatek, K

    2015-01-01

    A liquid chromatography - diode array detector (HPLC-DAD) procedure has been developed for the determination of oxytetracycline (OTC), tetracycline (TC), chlorotetracycline (CTC), doxycycline (DC), enrofloxacin (ENR), ciprofloxacin (CIP), sarafloxacin (SAR) and flumequine (FLU) residues in animal drinking water. This method was applied to animal drinking water. Solid-phase extraction (SPE) clean-up on an Oasis HLB cartridge allowed an extract suitable for liquid chromatographic analysis to be obtained. Chromatographic separation was carried out on a C18 analytical column, using gradient elution with 0.1% trifluoroacetic acid - acetonitrile - methanol at 30°C. The flow-rate was 0.7 mL/min and the eluate was analysed at 330 nm. The whole procedure was evaluated according to the requirements of the Commission Decision 2002/657/EC, determining specificity, decision limit (CCα), detection capacity (CCβ), limit of detection (LOD), limit of quantification (LOQ), precision and accuracy during validation of the method. The recoveries of TCs and FQs from spiked samples at the levels of 10, 100 and 1000 μg/L were higher than 82%. The developed method based on HPLC-DAD has been applied for the determination of four tetracyclines and four fluoroquinolones in animal drinking water samples.

  17. Evaluation of a gas chromatography method for azelaic acid determination in selected biological samples

    PubMed Central

    Garelnabi, Mahdi; Litvinov, Dmitry; Parthasarathy, Sampath

    2010-01-01

    Background: Azelaic acid (AzA) is the best known dicarboxilic acid to have pharmaceutical benefits and clinical applications and also to be associated with some diseases pathophysiology. Materials and Methods: We extracted and methylesterified AzA and determined its concentration in human plasma obtained from healthy individuals and also in mice fed AzA containing diet for three months. Results: AzA was detected in Gas Chromatography (GC) and confirmed by Liquid chromatography mass spectrometry (LCMS), and gas chromatography mass spectrometry (GCMC). Our results have shown that AzA can be determined efficiently in selected biological samples by GC method with 1nM limit of detection (LoD) and the limit of quantification (LoQ); was established at 50nM. Analytical Sensitivity as assayed by hexane demonstrated an analytical sensitivity at 0.050nM. The method has demonstrated 8-10% CV batch repeatability across the sample types and 13-18.9% CV for the Within-Lab Precision analysis. The method has shown that AzA can efficiently be recovered from various sample preparation including liver tissue homogenate (95%) and human plasma (97%). Conclusions: Because of its simplicity and lower limit of quantification, the present method provides a useful tool for determining AzA in various biological sample preparations. PMID:22558586

  18. Evaluation of a gas chromatography method for azelaic acid determination in selected biological samples.

    PubMed

    Garelnabi, Mahdi; Litvinov, Dmitry; Parthasarathy, Sampath

    2010-09-01

    Azelaic acid (AzA) is the best known dicarboxilic acid to have pharmaceutical benefits and clinical applications and also to be associated with some diseases pathophysiology. We extracted and methylesterified AzA and determined its concentration in human plasma obtained from healthy individuals and also in mice fed AzA containing diet for three months. AzA was detected in Gas Chromatography (GC) and confirmed by Liquid chromatography mass spectrometry (LCMS), and gas chromatography mass spectrometry (GCMC). Our results have shown that AzA can be determined efficiently in selected biological samples by GC method with 1nM limit of detection (LoD) and the limit of quantification (LoQ); was established at 50nM. Analytical Sensitivity as assayed by hexane demonstrated an analytical sensitivity at 0.050nM. The method has demonstrated 8-10% CV batch repeatability across the sample types and 13-18.9% CV for the Within-Lab Precision analysis. The method has shown that AzA can efficiently be recovered from various sample preparation including liver tissue homogenate (95%) and human plasma (97%). Because of its simplicity and lower limit of quantification, the present method provides a useful tool for determining AzA in various biological sample preparations.

  19. Ultimate detectability of volatile organic compounds: how much further can we reduce their ambient air sample volumes for analysis?

    PubMed

    Kim, Yong-Hyun; Kim, Ki-Hyun

    2012-10-02

    To understand the ultimately lowest detection range of volatile organic compounds (VOCs) in air, application of a high sensitivity analytical system was investigated by coupling thermal desorption (TD) technique with gas chromatography (GC) and time-of-flight (TOF) mass spectrometry (MS). The performance of the TD-GC/TOF MS system was evaluated using liquid standards of 19 target VOCs prepared in the range of 35 pg to 2.79 ng per μL. Studies were carried out using both total ion chromatogram (TIC) and extracted ion chromatogram (EIC) mode. EIC mode was used for calibration to reduce background and to improve signal-to-noise. The detectability of 19 target VOCs, if assessed in terms of method detection limit (MDL, per US EPA definition) and limit of detection (LOD), averaged 5.90 pg and 0.122 pg, respectively, with the mean coefficient of correlation (R(2)) of 0.9975. The minimum quantifiable mass of target analytes, when determined using real air samples by the TD-GC/TOF MS, is highly comparable to the detection limits determined experimentally by standard. In fact, volumes for the actual detection of the major aromatic VOCs like benzene, toluene, and xylene (BTX) in ambient air samples were as low as 1.0 mL in the 0.11-2.25 ppb range. It was thus possible to demonstrate that most target compounds including those in low abundance could be reliably quantified at concentrations down to 0.1 ppb at sample volumes of less than 10 mL. The unique sensitivity of this advanced analytical system can ultimately lead to a shift in field sampling strategy with smaller air sample volumes facilitating faster, simpler air sampling (e.g., use of gas syringes rather than the relative complexity of pumps or bags/canisters), with greatly reduced risk of analyte breakthrough and minimal interference, e.g., from atmospheric humidity. The improved detection limits offered by this system can also enhance accuracy and measurement precision.

  20. Total Acid Value Titration of Hydrotreated Biomass Fast Pyrolysis Oil: Determination of Carboxylic Acids and Phenolics with Multiple End-Point Detection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Christensen, E.; Alleman, T. L.; McCormick, R. L.

    Total acid value titration has long been used to estimate corrosive potential of petroleum crude oil and fuel oil products. The method commonly used for this measurement, ASTM D664, utilizes KOH in isopropanol as the titrant with potentiometric end point determination by pH sensing electrode and Ag/AgCl reference electrode with LiCl electrolyte. A natural application of the D664 method is titration of pyrolysis-derived bio-oil, which is a candidate for refinery upgrading to produce drop in fuels. Determining the total acid value of pyrolysis derived bio-oil has proven challenging and not necessarily amenable to the methodology employed for petroleum products duemore » to the different nature of acids present. We presented an acid value titration for bio-oil products in our previous publication which also utilizes potentiometry using tetrabutylammonium hydroxide in place of KOH as the titrant and tetraethylammonium bromide in place of LiCl as the reference electrolyte to improve the detection of these types of acids. This method was shown to detect numerous end points in samples of bio-oil that were not detected by D664. These end points were attributed to carboxylic acids and phenolics based on the results of HPLC and GC-MS studies. Additional work has led to refinement of the method and it has been established that both carboxylic acids and phenolics can be determined accurately. Use of pH buffer calibration to determine half-neutralization potentials of acids in conjunction with the analysis of model compounds has allowed us to conclude that this titration method is suitable for the determination of total acid value of pyrolysis oil and can be used to differentiate and quantify weak acid species. The measurement of phenolics in bio-oil is subject to a relatively high limit of detection, which may limit the utility of titrimetric methodology for characterizing the acidic potential of pyrolysis oil and products.« less

  1. Determination of bupropion using liquid chromatography with fluorescence detection in pharmaceutical preparations, human plasma and human urine.

    PubMed

    Ulu, Sevgi Tatar; Tuncel, Muzaffer

    2012-05-01

    A novel pre-column derivatization reversed-phase high-performance liquid chromatography with fluorescence detection is described for the determination of bupropion in pharmaceutical preparation, human plasma and human urine using mexiletine as internal standard. The proposed method is based on the reaction of 4-chloro-7-nitrobenzofurazan (NBD-Cl) with bupropion to produce a fluorescent derivative. The derivative formed is monitored on a C18 (150 mm × 4.6 mm i.d., 5 µm) column using a mobile phase consisting of methanol-water 75:25 (v/v), at a flow-rate of 1.2 mL/min and detected fluorimetrically at λ(ex) = 458 and λ(em) = 533 nm. The assay was linear over the concentration ranges of 5-500 and 10-500 ng/mL for plasma and urine, respectively. The limits of detection and quantification were calculated to be 0.24 and 0.72 ng/mL for plasma and urine, respectively (inter-day results). The recoveries obtained for plasma and urine were 97.12% ± 0.45 and 96.00% ± 0.45, respectively. The method presents good performance in terms of precision, accuracy, specificity, linearity, detection and quantification limits and robustness. The proposed method is applied to determine bupropion in commercially available tablets. The results were compared with an ultraviolet spectrophotometry method using t- and F-tests. © The Author [2012]. Published by Oxford University Press. All rights reserved.

  2. Study of gamma detection capabilities of the REWARD mobile spectroscopic system

    NASA Astrophysics Data System (ADS)

    Balbuena, J. P.; Baptista, M.; Barros, S.; Dambacher, M.; Disch, C.; Fiederle, M.; Kuehn, S.; Parzefall, U.

    2017-07-01

    REWARD is a novel mobile spectroscopic radiation detector system for Homeland Security applications. The system integrates gamma and neutron detection equipped with wireless communication. A comprehensive simulation study on its gamma detection capabilities in different radioactive scenarios is presented in this work. The gamma detection unit consists of a precise energy resolution system based on two stacked (Cd,Zn)Te sensors working in coincidence sum mode. The volume of each of these CZT sensors is 1 cm3. The investigated energy windows used to determine the detection capabilities of the detector correspond to the gamma emissions from 137Cs and 60Co radioactive sources (662 keV and 1173/1333 keV respectively). Monte Carlo and Technology Computer-Aided Design (TCAD) simulations are combined to determine its sensing capabilities for different radiation sources and estimate the limits of detection of the sensing unit as a function of source activity for several shielding materials.

  3. Highly sensitive detection of nanoparticles with a self-referenced and self-heterodyned whispering-gallery Raman microlaser.

    PubMed

    Özdemir, Şahin Kaya; Zhu, Jiangang; Yang, Xu; Peng, Bo; Yilmaz, Huzeyfe; He, Lina; Monifi, Faraz; Huang, Steven He; Long, Gui Lu; Yang, Lan

    2014-09-16

    Optical whispering-gallery-mode resonators (WGMRs) have emerged as promising platforms for label-free detection of nano-objects. The ultimate sensitivity of WGMRs is determined by the strength of the light-matter interaction quantified by quality factor/mode volume, Q/V, and the resolution is determined by Q. To date, to improve sensitivity and precision of detection either WGMRs have been doped with rare-earth ions to compensate losses and increase Q or plasmonic resonances have been exploited for their superior field confinement and lower V. Here, we demonstrate, for the first time to our knowledge, enhanced detection of single-nanoparticle-induced mode splitting in a silica WGMR via Raman gain-assisted loss compensation and WGM Raman microlaser. In particular, the use of the Raman microlaser provides a dopant-free, self-referenced, and self-heterodyned scheme with a detection limit ultimately determined by the thermorefractive noise. Notably, we detected and counted individual nanoparticles with polarizabilities down to 3.82 × 10(-6) μm(3) by monitoring a heterodyne beatnote signal. This level of sensitivity is achieved without exploiting plasmonic effects, external references, or active stabilization and frequency locking. Single nanoparticles are detected one at a time; however, their characterization by size or polarizability requires ensemble measurements and statistical averaging. This dopant-free scheme retains the inherited biocompatibility of silica and could find widespread use for sensing in biological media. The Raman laser and operation band of the sensor can be tailored for the specific sensing environment and the properties of the targeted materials by changing the pump laser wavelength. This scheme also opens the possibility of using intrinsic Raman or parametric gain for loss compensation in other systems where dissipation hinders progress and limits applications.

  4. Simultaneous determination of ezetimibe and simvastatin in pharmaceutical preparations by MEKC.

    PubMed

    Yardimci, Ceren; Ozaltin, Nuran

    2010-02-01

    A micellar electrokinetic capillary chromatography method was developed and validated for the simultaneous determination of ezetimibe and simvastatin in pharmaceutical preparations. The influence of buffer concentration, buffer pH, sodium dodecyl sulphate (SDS) concentration, organic modifier, capillary temperature, applied voltage, and injection time was investigated, and the method validation studies were performed. The optimum separation for these analytes was achieved in less than 10 min at 30 degrees C with a fused-silica capillary column (56 cm x 50 microm i.d.) and a 25mM borate buffer at pH 9.0 containing 25mM SDS and 10% (v/v) acetonitrile. The samples were injected hydrodynamically for 3 s at 50 mbar, and the applied voltage was +30.0 kV. Detection wavelength was set at 238 nm. Diflunisal was used as internal standard. The method was suitably validated with respect to stability, specificity, linearity, limits of detection and quantification, accuracy, precision, and robustness. The limits of detection and quantification were 1.0 and 2.0 microg/mL for both ezetimibe and simvastatin, respectively. The method developed was successfully applied to the simultaneous determination of ezetimibe and simvastatin in pharmaceutical preparations.

  5. Simultaneous determination of 11 bioactive compounds in Jaeumganghwa-tang by high performance liquid chromatography-diode array detection

    PubMed Central

    Yun, Bo-Ra; Weon, Jin Bae; Lee, Jiwoo; Eom, Min Rye; Ma, Choong Je

    2014-01-01

    Background: Jaeumganghwa-tang (JEGH) is a traditional Korean herbal medicine for the treatment of chronic bronchitis, nephritis and diabetes mellitus. Objective: A high performance liquid chromatography-diode array detector (HPLC-DAD) method was developed for simultaneous determination of 11 major compounds such as 5- hydroxymethylfurfural, mangiferin, paeoniflorin, nodakenin, naringin, hesperidin, decursinol, berberine, glycyrrhizin, atractylenolide III and decursin, in JEGH. Materials and Methods: The separation was conducted on Shishedo C18 column with gradient elution of 0.1% trifluoroacetic acid–acetonitrile. Detection of wavelength was set at 205, 250, 280 and 330 nm. Results: The developed analysis showed a good linearity (R2 >0.9997). The range of limit of detection and limit of quantification were observed from 0.04 to 0.43 and from 0.11 to 1.30, respectively. The intra- and inter-day test relative standard deviations (RSD) were less than 3% and the accuracy was 95.98-108.44%. The recoveries were between 92.75% and 109.19% and RSD range of recoveries was measured from 0.52% to 2.78%. Conclusion: This HPLC-DAD method can be successfully applied for simultaneous determination of 11 major compounds in JEGH samples. PMID:24991100

  6. A new cloud point extraction procedure for determination of inorganic antimony species in beverages and biological samples by flame atomic absorption spectrometry.

    PubMed

    Altunay, Nail; Gürkan, Ramazan

    2015-05-15

    A new cloud-point extraction (CPE) for the determination of antimony species in biological and beverages samples has been established with flame atomic absorption spectrometry (FAAS). The method is based on the fact that formation of the competitive ion-pairing complex of Sb(III) and Sb(V) with Victoria Pure Blue BO (VPB(+)) at pH 10. The antimony species were individually detected by FAAS. Under the optimized conditions, the calibration range for Sb(V) is 1-250 μg L(-1) with a detection limit of 0.25 μg L(-1) and sensitive enhancement factor of 76.3 while the calibration range for Sb(III) is 10-400 μg L(-1) with a detection limit of 5.15 μg L(-1) and sensitive enhancement factor of 48.3. The precision as a relative standard deviation is in range of 0.24-2.35%. The method was successfully applied to the speciative determination of antimony species in the samples. The validation was verified by analysis of certified reference materials (CRMs). Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. Simultaneous determination of emamectin and ivermectin residues in Atlantic salmon muscle by liquid chromatography with fluorescence detection.

    PubMed

    van de Riet, J M; Brothers, N N; Pearce, J N; Burns, B G

    2001-01-01

    A liquid chromatographic (LC) method for determining residues of the antiparasitic drugs emamectin (EMA) and ivermectin (IVR) in fish tissues has been developed. EMA and IVR residues are extracted with acetonitrile and cleaned up on a C18 solid-phase extraction column. Extracts are derivatized with 1-methylimidazole and trifluoroacetic anhydride and the components are determined by LC on a C18 reversed-phase column with fluorescence detection (excitation: 365 nm, emission: 470 nm). The mobile phase is 94% acetonitrile-water run isocratically. Calibration curves were linear between 1 and 32 ng injected for both EMA and IVR. The limit of detection for both analytes was 0.5 ng/g, with a limit of quantitation of 1.5 ng/g. Recoveries of EMA and IVR added to salmon muscle averaged 96 +/- 9% and 86 +/- 6%, respectively, at levels between 5 and 80 ng/g. The percent relative standard deviation for the described method was less than 7% over the range of concentrations studied. The operational errors, interferences, and recoveries for fortified samples compare favorably with an established IVR method. The recommended method is simple, rapid, and specific for monitoring residues of EMA and IVR in Atlantic salmon muscle.

  8. Determination of trace-level haloacetic acids in drinking water by ion chromatography-inductively coupled plasma mass spectrometry.

    PubMed

    Liu, Yongjian; Mou, Shifen; Chen, Dengyun

    2004-06-11

    A new method for the determination of nine haloacetic acids (HAAs) with ion chromatography (IC) coupled to inductively coupled plasma mass spectrometry (ICP-MS) was developed. With the very hydrophilic anion-exchange column and steep gradient of sodium hydroxide, the nine HAAs could be well separated in 15 min. After suppression with an ASRS suppressor that was introduced in between IC and ICP-MS, the background was much decreased, the interference caused by sodium ion present in eluent was removed, and the sensitivities of HAAs were greatly improved. The chlorinated and brominated HAAs could be detected as 35ClO and 79Br without interference of the matrix due to the elemental selective ICP-MS. The detection limits for mono-, di-, trichloroacetic acids were between 15.6 and 23.6 microg/l. For the other six bromine-containing HAAs, the detection limits were between 0.34 and 0.99 microg/l. With the pretreatment of OnGuard Ag cartridge to remove high concentration of chloride in sample, the developed method could be applied to the determination of HAAs in many drinking water matrices.

  9. Determination of 2-alkylcyclobutanones by combining precolumn derivatization with 1-naphthalenyl hydrazine and ultra-performance liquid chromatography with fluorescence detection.

    PubMed

    Meng, Xiangpeng; Tong, Tong; Wang, Lianrong; Liu, Hanxia; Chan, Wan

    2016-05-01

    2-Alkylcyclobutanones (2-ACBs) are uniquely formed when triglycerides-containing food products are exposed to ionizing radiation. Thus, 2-ACBs have been used as marker molecules to identify irradiated food. Most methods to determine 2-ACBs involve mass spectrometric detection after chromatographic separation. The spectrofluorometer is rarely used to determine 2-ACBs because these molecules do not fluoresce. In this study, we developed an ultra-performance liquid chromatography (UPLC) method to determine 2-ACBs. 2-ACBs were converted into fluorophores after reacting with 1-naphthalenyl hydrazine to facilitate their sensitive and selective detection using a fluorescence detector (FLD). Analysis of 2-ACBs using our developed UPLC-FLD method allows sensitive determination of 2-ACBs at a detection limit of 2 ng 2-ACBs per g of fat (30 pg/injection), which is significantly lower than that of existing analytical methods. After validation for trueness and precision, the method was applied to γ-irradiated chicken samples to determine their 2-ACB content. Comparative studies employing liquid chromatography-tandem mass spectrometric method revealed no systematic difference between the two methods, thereby demonstrating that the proposed UPLC-FLD method can be suitably used to determine 2-ACBs in irradiated foodstuffs. Graphical Abstract Determination of radiation-induced food-borne 2-dodecylcyclobutanone and 2-tetradecylcyclobutanone by combining 1-naphthalenyl hydrazine derivatization and ultra-performance liquid chromatography with fluorescence detection.

  10. Evaluation of sensitivity of TaqMan RT-PCR for rubella virus detection in clinical specimens.

    PubMed

    Okamoto, Kiyoko; Mori, Yoshio; Komagome, Rika; Nagano, Hideki; Miyoshi, Masahiro; Okano, Motohiko; Aoki, Yoko; Ogura, Atsushi; Hotta, Chiemi; Ogawa, Tomoko; Saikusa, Miwako; Kodama, Hiroe; Yasui, Yoshihiro; Minagawa, Hiroko; Kurata, Takako; Kanbayashi, Daiki; Kase, Tetsuo; Murata, Sachiko; Shirabe, Komei; Hamasaki, Mitsuhiro; Kato, Takashi; Otsuki, Noriyuki; Sakata, Masafumi; Komase, Katsuhiro; Takeda, Makoto

    2016-07-01

    An easy and reliable assay for detection of the rubella virus is required to strengthen rubella surveillance. Although a TaqMan RT-PCR assay for detection of the rubella virus has been established in Japan, its utility for diagnostic purposes has not been tested. To allow introduction of the TaqMan RT-PCR into the rubella surveillance system in Japan, the sensitivity of the assay was determined using representative strains for all genotypes and clinical specimens. The detection limits of the method for individual genotypes were examined using viral RNA extracted from 13 representative strains. The assay was also tested at 10 prefectural laboratories in Japan, designated as local reference laboratories for measles and rubella, to allow nationwide application of the assay. The detection limits and amplification efficiencies of the assay were similar among all the representative strains of the 13 genotypes. The TaqMan RT-PCR could detect approximately 90% of throat swab and urine samples taken up to 5days of illness. These samples were determined positive by a highly sensitive nested RT-PCR. The TaqMan RT-PCR could detect at least 10 pfu of rubella virus. Although the sensitivity was somewhat lower than that of the conventional nested RT-PCR, the TaqMan RT-PCR could be more practical to routine tests for rubella laboratory diagnosis and detection in view of the rapid response and reducing risks of contamination. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Comparison of liquid chromatographic and bioassay procedures for determining depletion of intramuscularly injected tylosin.

    PubMed

    Moats, W A; Harris, E W; Steele, N C

    1985-01-01

    Crossbred pigs weighing 80-110 kg were injected intramuscularly in the ham with 8.8 mg/kg tylosin. Animals were slaughtered in groups of 3 at intervals of 4 h, and 1, 2, 4, and 8 days after injection, and samples of blood, injected muscle, uninjected muscle, liver, and kidney were analyzed by liquid chromatography (LC) and by bioassay using Sarcina lutea as the test organism. The LC method was far more sensitive with a detection limit of less than 0.1 ppm, while the detection limit by bioassay was about 0.5 ppm in tissue. Results by bioassay and LC sometimes differed considerably for tissue samples. Residues in all tissues were below the tolerance limit of 0.2 ppm at 24 h, except in the injected muscle in one animal. Residues were not detected in any tissue of any animal at 48 h after treatment.

  12. SU-E-T-144: Effective Analysis of VMAT QA Generated Trajectory Log Files for Medical Accelerator Predictive Maintenance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Able, CM; Baydush, AH; Nguyen, C

    Purpose: To determine the effectiveness of SPC analysis for a model predictive maintenance process that uses accelerator generated parameter and performance data contained in trajectory log files. Methods: Each trajectory file is decoded and a total of 131 axes positions are recorded (collimator jaw position, gantry angle, each MLC, etc.). This raw data is processed and either axis positions are extracted at critical points during the delivery or positional change over time is used to determine axis velocity. The focus of our analysis is the accuracy, reproducibility and fidelity of each axis. A reference positional trace of the gantry andmore » each MLC is used as a motion baseline for cross correlation (CC) analysis. A total of 494 parameters (482 MLC related) were analyzed using Individual and Moving Range (I/MR) charts. The chart limits were calculated using a hybrid technique that included the use of the standard 3σ limits and parameter/system specifications. Synthetic errors/changes were introduced to determine the initial effectiveness of I/MR charts in detecting relevant changes in operating parameters. The magnitude of the synthetic errors/changes was based on: TG-142 and published analysis of VMAT delivery accuracy. Results: All errors introduced were detected. Synthetic positional errors of 2mm for collimator jaw and MLC carriage exceeded the chart limits. Gantry speed and each MLC speed are analyzed at two different points in the delivery. Simulated Gantry speed error (0.2 deg/sec) and MLC speed error (0.1 cm/sec) exceeded the speed chart limits. Gantry position error of 0.2 deg was detected by the CC maximum value charts. The MLC position error of 0.1 cm was detected by the CC maximum value location charts for every MLC. Conclusion: SPC I/MR evaluation of trajectory log file parameters may be effective in providing an early warning of performance degradation or component failure for medical accelerator systems.« less

  13. Rapid determination of isoamyl nitrite in pharmaceutical preparations by flow injection analysis with on-line UV irradiation and luminol chemiluminescence detection.

    PubMed

    Kishikawa, Naoya; Kondo, Naoko; Amponsaa-Karikari, Abena; Kodamatani, Hitoshi; Ohyama, Kaname; Nakashima, Kenichiro; Yamazaki, Shigeo; Kuroda, Naotaka

    2014-02-01

    Isoamyl nitrite is used as a therapeutic reagent for cardiac angina and as an antidote for cyanide poisoning, but it is abused because of its euphoric properties. Therefore, a method to determine isoamyl nitrite is required in many fields, including pharmaceutical and forensic studies. In this study, a simple, rapid and sensitive method for the determination of isoamyl nitrite was developed using a flow injection analysis system equipped with a chemiluminescence detector and on-line photoreactor. This method is based on on-line ultraviolet irradiation of isoamyl nitrite and subsequent luminol chemiluminescence detection without the addition of an oxidant. A linear standard curve was obtained up to 1.0 μM of isoamyl nitrite with a detection limit (blank + 3SD) of 0.03 μM. The method was successfully applied to determine isoamyl nitrite content in pharmaceutical preparations. Copyright © 2013 John Wiley & Sons, Ltd.

  14. Simultaneous determination of niacin and pyridoxine at trace levels by using diode array high-performance liquid chromatography and liquid chromatography with quadrupole time-of-flight tandem mass spectrometry.

    PubMed

    Sel, Sabriye; Öztürk Er, Elif; Bakırdere, Sezgin

    2017-12-01

    A highly sensitive and simple diode-array high-performance liquid chromatography and liquid chromatography with quadrupole time-of-flight tandem mass spectrometry method was developed for the simultaneous determination of niacin and pyridoxine in pharmaceutical drugs, tap water, and wastewater samples. To determine the in vivo behavior of niacin and pyridoxine, analytes were subjected to simulated gastric conditions. The calibration plots of the diode-array high-performance liquid chromatography and liquid chromatography with quadrupole time-of-flight tandem mass spectrometry method showed good linearity over a wide concentration range with close to 1.0 correlation coefficients for both analytes. The limit of detection/limit of quantitation values for liquid chromatography quadrupole time-of-flight tandem mass spectrometry analysis were 1.98/6.59 and 1.3/4.4 μg/L for niacin and pyridoxine, respectively, while limit of detection/limit of quantitation values for niacin and pyridoxine in high-performance liquid chromatography analysis were 3.7/12.3 and 5.7/18.9 μg/L, respectively. Recovery studies were also performed to show the applicability of the developed methods, and percentage recovery values were found to be 90-105% in tap water and 94-97% in wastewater for both analytes. The method was also successfully applied for the qualitative and quantitative determination of niacin and pyridoxine in drug samples. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Sensitivity and accuracy of high-throughput metabarcoding methods for early detection of invasive fish species

    NASA Astrophysics Data System (ADS)

    Hatzenbuhler, Chelsea; Kelly, John R.; Martinson, John; Okum, Sara; Pilgrim, Erik

    2017-04-01

    High-throughput DNA metabarcoding has gained recognition as a potentially powerful tool for biomonitoring, including early detection of aquatic invasive species (AIS). DNA based techniques are advancing, but our understanding of the limits to detection for metabarcoding complex samples is inadequate. For detecting AIS at an early stage of invasion when the species is rare, accuracy at low detection limits is key. To evaluate the utility of metabarcoding in future fish community monitoring programs, we conducted several experiments to determine the sensitivity and accuracy of routine metabarcoding methods. Experimental mixes used larval fish tissue from multiple “common” species spiked with varying proportions of tissue from an additional “rare” species. Pyrosequencing of genetic marker, COI (cytochrome c oxidase subunit I) and subsequent sequence data analysis provided experimental evidence of low-level detection of the target “rare” species at biomass percentages as low as 0.02% of total sample biomass. Limits to detection varied interspecifically and were susceptible to amplification bias. Moreover, results showed some data processing methods can skew sequence-based biodiversity measurements from corresponding relative biomass abundances and increase false absences. We suggest caution in interpreting presence/absence and relative abundance in larval fish assemblages until metabarcoding methods are optimized for accuracy and precision.

  16. [The determination of the herbicide glyphosate and its chief metabolite aminomethylphosphonic acid (AMPA) in drinking water with the aid of HPLC].

    PubMed

    Gauch, R; Leuenberger, U; Müller, U

    1989-01-01

    A method for the determination of glyphosate and its major metabolite aminomethylphosphonic acid (AMPA) is described. With a detection limit of 0.02 microgram/l, the method suitably fulfills the requirements of the Swiss legislation (tolerance value of 0.1 micrograms/l water). The compounds are derivatized directly in the original water sample with 9-fluorenylmethyl chloroformate (FMOCC1) in order to obtain extractable and fluorescent derivatives. These are extracted with organic solvents and determined by HPLC using a fluorescence detector. Neither of the compounds could be detected in 151 tap water samples from the Canton of Berne.

  17. Simultaneous determination of seven phthalic acid esters in beverages using ultrasound and vortex-assisted dispersive liquid-liquid microextraction followed by high-performance liquid chromatography.

    PubMed

    Yılmaz, Pelin Köseoğlu; Ertaş, Abdulselam; Kolak, Ufuk

    2014-08-01

    A sensitive, rapid, and simple high-performance liquid chromatography with UV detection method was developed for the simultaneous determination of seven phthalic acid esters (dimethyl phthalate, dipropyl phthalate, di-n-butyl phthalate, benzyl butyl phthalate, dicyclohexyl phthalate, di-(2-ethylhexyl) phthalate, and di-n-octyl phthalate) in several kinds of beverage samples. Ultrasound and vortex-assisted dispersive liquid-liquid microextraction method was used. The separation was performed using an Intersil ODS-3 column (C18 , 250 × 4.6 mm, 5.0 μm) and a gradient elution with a mobile phase consisting of MeOH/ACN (50:50) and 0.2 M KH2 PO4 buffer. Analytes were detected by a UV detector at 230 nm. The developed method was validated in terms of linearity, limit of detection, limit of quantification, repeatability, accuracy, and recovery. Calibration equations and correlation coefficients (> 0.99) were calculated by least squares method with weighting factor. The limit of detection and quantification were in the range of 0.019-0.208 and 0.072-0.483 μg/L. The repeatability and intermediate precision were determined in terms of relative standard deviation to be within 0.03-3.93 and 0.02-4.74%, respectively. The accuracy was found to be in the range of -14.55 to 15.57% in terms of relative error. Seventeen different beverage samples in plastic bottles were successfully analyzed, and ten of them were found to be contaminated by different phthalic acid esters. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Detection of diethylene glycol adulteration in propylene glycol--method validation through a multi-instrument collaborative study.

    PubMed

    Li, Xiang; Arzhantsev, Sergey; Kauffman, John F; Spencer, John A

    2011-04-05

    Four portable NIR instruments from the same manufacturer that were nominally identical were programmed with a PLS model for the detection of diethylene glycol (DEG) contamination in propylene glycol (PG)-water mixtures. The model was developed on one spectrometer and used on other units after a calibration transfer procedure that used piecewise direct standardization. Although quantitative results were produced, in practice the instrument interface was programmed to report in Pass/Fail mode. The Pass/Fail determinations were made within 10s and were based on a threshold that passed a blank sample with 95% confidence. The detection limit was then established as the concentration at which a sample would fail with 95% confidence. For a 1% DEG threshold one false negative (Type II) and eight false positive (Type I) errors were found in over 500 samples measured. A representative test set produced standard errors of less than 2%. Since the range of diethylene glycol for economically motivated adulteration (EMA) is expected to be above 1%, the sensitivity of field calibrated portable NIR instruments is sufficient to rapidly screen out potentially problematic materials. Following method development, the instruments were shipped to different sites around the country for a collaborative study with a fixed protocol to be carried out by different analysts. NIR spectra of replicate sets of calibration transfer, system suitability and test samples were all processed with the same chemometric model on multiple instruments to determine the overall analytical precision of the method. The combined results collected for all participants were statistically analyzed to determine a limit of detection (2.0% DEG) and limit of quantitation (6.5%) that can be expected for a method distributed to multiple field laboratories. Published by Elsevier B.V.

  19. Determination of phenylurea herbicides in water samples using online sorptive preconcentration and high-performance liquid chromatography with UV or electrospray mass spectrometric detection.

    PubMed

    Baltussen, E; Snijders, H; Janssen, H G; Sandra, P; Cramers, C A

    1998-04-10

    A recently developed method for the extraction of organic micropollutants from aqueous samples based on sorptive enrichment in columns packed with 100% polydimethylsiloxane (PDMS) particles was coupled on-line with HPLC analysis. The sorptive enrichment procedure originally developed for relatively nonpolar analytes was used to preconcentrate polar phenylurea herbicides from aqueous samples. PDMS extraction columns of 5, 10 and 25 cm were used to extract the herbicides from distilled, tap and river water samples. A model that allows prediction of retention and breakthrough volumes is presented. Despite the essentially apolar nature of the PDMS material, it is possible to concentrate sample volumes up to 10 ml on PDMS cartridges without losses of the most polar analyte under investigation, fenuron. For less polar analytes significantly larger sample volumes can be applied. Since standard UV detection does not provide adequate selectivity for river water samples, an electrospray (ES)-MS instrument was used to determine phenylurea herbicides in a water sample from the river Dommel. Methoxuron was present at a level of 80 ng/l. The detection limit of the current set-up, using 10 ml water samples and ES-MS detection is 10 ng/l in river water samples. Strategies for further improvement of the detection limits are identified.

  20. Establishment and application of a novel isothermal amplification assay for rapid detection of chloroquine resistance (K76T) in Plasmodium falciparum

    PubMed Central

    Chahar, Madhvi; Mishra, Neelima; Anvikar, Anup; Dixit, Rajnikant; Valecha, Neena

    2017-01-01

    Chloroquine (CQ) resistance in Plasmodium falciparum is determined by the mutations in the chloroquine resistance transporter (Pfcrt) gene. The point mutation at codon 76 (K76T), which has been observed in more than 91% of P. falciparum isolates in India, is the major determinant of CQ resistance. To overcome the limitations and challenges of traditional methods, in this investigation we developed an easy to use loop mediated isothermal amplification (LAMP) protocol for rapid detection of the K76T mutation associated with CQ resistance in P. falciparum with naked eye visualization. In- house designed primers were synthesized and optimized to specifically distinguish the CQ resistant mutants of P. falciparum. The LAMP reaction was optimal at 61 °C for 60 min and calcein dye was added prior to amplification to enable visual detection. We demonstrate the detection limit of <2 ng/μl respectively, supporting the high sensitivity of this calcein based LAMP method. To the best of our knowledge this is the first report on the establishment of an easy, reliable and cost effective LAMP assay for rapid and specific detection of highly CQ resistance in P. falciparum malaria. PMID:28134241

  1. QUANTITATIVE ENZYME-LINKED IMMUNOSORBENT ASSAY FOR DETERMINATION OF POLYCHLORINATED BIPHENYLS IN ENVIRONMENTAL SOIL AND SEDIMENT SAMPLES

    EPA Science Inventory

    An enzyme-linked immunosorbent assay (ELISA) for the quantitative determination of Aroclors 1242, 1248, 1254, and 1260 in soil and sediments was developed and its performance compared with that of gas chromatography (GC). The detection limits for Aroclors 1242 and 1248 in soil ar...

  2. Laser-Induced Breakdown Spectroscopy of Trace Metals

    NASA Technical Reports Server (NTRS)

    Simons, Stephen (Technical Monitor); VanderWal, Randall L.; Ticich, Thomas M.; West, Joseph R., Jr.

    2004-01-01

    An alternative approach for laser-induced breakdown spectroscopy (LIBS) determination of trace metal determination in liquids is demonstrated. The limits of detection (LOD) for the technique ranged from 10 ppb to 10 ppm for 15 metals metals (Mg, Al, Si, Ca, Ti, Cr, Fe, Co, Ni, Cu, Zn, As, Cd, Hg, Pb) tested.

  3. 40 CFR 63.2262 - How do I conduct performance tests and establish operating requirements?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... method detection limit is less than or equal to 1 parts per million by volume, dry basis (ppmvd..., percent (determined for reconstituted wood product presses and board coolers as required in Table 4 to... = capture efficiency, percent (determined for reconstituted wood product presses and board coolers as...

  4. 40 CFR 63.2262 - How do I conduct performance tests and establish operating requirements?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... method detection limit is less than or equal to 1 parts per million by volume, dry basis (ppmvd..., percent (determined for reconstituted wood product presses and board coolers as required in Table 4 to... = capture efficiency, percent (determined for reconstituted wood product presses and board coolers as...

  5. 40 CFR 63.2262 - How do I conduct performance tests and establish operating requirements?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... method detection limit is less than or equal to 1 parts per million by volume, dry basis (ppmvd..., percent (determined for reconstituted wood product presses and board coolers as required in Table 4 to... = capture efficiency, percent (determined for reconstituted wood product presses and board coolers as...

  6. Determination of Lead in Urine by Atomic Absorption Spectrophotometry1

    PubMed Central

    Selander, Stig; Cramé, Kim

    1968-01-01

    A method for the determination of lead in urine by means of atomic absorption spectrophotometry (AAS) is described. A combination of wet ashing and extraction with ammonium pyrrolidine dithiocarbamate into isobutylmethylketone was used. The sensitivity was about 0·02 μg./ml. for 1% absorption, and the detection limit was about 0·02 μg./ml. with an instrumental setting convenient for routine analyses of urines. Using the scale expansion technique, the detection limit was below 0·01 μg./ml., but it was found easier to determine urinary lead concentrations below 0·05 μg./ml. by concentrating the lead in the organic solvent by increasing the volume of urine or decreasing that of the solvent. The method was applied to fresh urines, stored urines, and to urines, obtained during treatment with chelating agents, of patients with lead poisoning. Urines with added inorganic lead were not used. The results agreed well with those obtained with a colorimetric dithizone extraction method (r = 0·989). The AAS method is somewhat more simple and allows the determination of smaller lead concentrations. PMID:5647975

  7. Selective determination of arginine-containing and tyrosine-containing peptides using capillary electrophoresis and laser-induced fluorescence detection.

    PubMed

    Cobb, K A; Novotny, M V

    1992-01-01

    The use of two different amino acid-selective fluorogenic reagents for the derivatization of peptides is investigated. One such scheme utilizes a selective reaction of benzoin with the guanidine moiety to derivatize arginine residues occurring in a peptide. The second scheme involves the formylation of tyrosine, followed by reaction with 4-methoxy-1,2-phenylenediamine. The use of capillary electrophoresis and laser-induced fluorescence detection allows enhanced efficiencies and sensitivities to be obtained for the separations of either arginine- or tyrosine-containing peptides. A helium-cadmium laser (325 nm) is ideally suited for the laser-based detection system due to a close match of the excitation maxima of derivatized peptides from both reactions. A detection limit of 270 amol is achieved for model arginine-containing peptides, while the detection limit for model tyrosine-containing peptides is measured at 390 amol. Both derivatization reactions are found to be useful for high-sensitivity peptide mapping applications in which only the peptides containing the derivatized amino acids are detected.

  8. Sample-morphology effects on x-ray photoelectron peak intensities. II. Estimation of detection limits for thin-film materials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Powell, Cedric J., E-mail: cedric.powell@nist.gov; Werner, Wolfgang S. M.; Smekal, Werner

    2014-09-01

    The authors show that the National Institute of Standards and Technology database for the simulation of electron spectra for surface analysis (SESSA) can be used to determine detection limits for thin-film materials such as a thin film on a substrate or buried at varying depths in another material for common x-ray photoelectron spectroscopy (XPS) measurement conditions. Illustrative simulations were made for a W film on or in a Ru matrix and for a Ru film on or in a W matrix. In the former case, the thickness of a W film at a given depth in the Ru matrix wasmore » varied so that the intensity of the W 4d{sub 5/2} peak was essentially the same as that for a homogeneous RuW{sub 0.001} alloy. Similarly, the thickness of a Ru film at a selected depth in the W matrix was varied so that the intensity of the Ru 3p{sub 3/2} peak matched that from a homogeneous WRu{sub 0.01} alloy. These film thicknesses correspond to the detection limits of each minor component for measurement conditions where the detection limits for a homogeneous sample varied between 0.1 at. % (for the RuW{sub 0.001} alloy) and 1 at. % (for the WRu{sub 0.01} alloy). SESSA can be similarly used to convert estimates of XPS detection limits for a minor species in a homogeneous solid to the corresponding XPS detection limits for that species as a thin film on or buried in the chosen solid.« less

  9. [Simultaneous determination of delta-9-tetrahydrocannabinol cannabidiol and cannabinol in edible oil using ultra performance liquid chromatography-tandem mass spectrometry].

    PubMed

    Zhang, Aizhi; Wang, Quanlin; Mo, Shijie

    2010-11-01

    A method for the simultaneous determination of delta-9-tetrahydrocannabinol (THC), cannabidiol (CBD) and cannabinol (CBN) in edible oil was developed using ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). The target compounds were extracted with methanol, purified by an LC-Alumina-N solid phase extraction cartridge, separated and detected by the UPLC-MS/MS. Quantitative analysis was corrected by an isotope internal standard method using delta-9-THC-D3 as internal standard. Average recoveries for the target compounds varied from 68.0% to 101.6% with the relative standard deviations ranging from 7.0% to 20.1% at three spiked levels. The limits of detection (LOD) of the method were from 0.06-0.17 microg/kg and the limits of quantification (LOQ) were in the range of 0.20-0.52 microg/kg. The results showed that the method is able to meet the requirements for the simultaneous determination of THC, CBD and CBN in edible oil.

  10. Determination of formetanate hydrochloride in fruit samples using liquid chromatography-mass selective detection or -tandem mass spectrometry.

    PubMed

    Podhorniak, Lynda V; Kamel, Alaa; Rains, Diane M

    2010-05-26

    A rapid multiresidue method that captures residues of the insecticide formetanate hydrochloride (FHCl) in selected fruits is described. The method was used to provide residue data for dietary exposure determinations of FHCl. Using an acetonitrile extraction with a dispersive cleanup based on AOAC International method 2007.01, also known as QuEChERS, which was further modified and streamlined, thousands of samples were successfully analyzed for FHCl residues. FHCl levels were determined both by liquid chromatography-single-stage mass spectrometry (LC-MS) and ultraperformance liquid chromatography (UPLC)-tandem mass spectrometry (LC-MS/MS). The target limit of detection (LOD) and the limit of quantitation (LOQ) achieved for FHCl were 3.33 and 10 ng/g, respectively, with LC-MS and 0.1 and 0.3 ng/g, respectively, with LC-MS/MS. Recoveries at these previously unpublished levels ranged from 95 to 109%. A set of 20-40 samples can be prepared in one working day by two chemists.

  11. Synchronous fluorescence based biosensor for albumin determination by cooperative binding of fluorescence probe in a supra-biomolecular host-protein assembly.

    PubMed

    Patra, Digambara

    2010-01-15

    A synchronous fluorescence probe based biosensor for estimation of albumin with high sensitivity and selectivity was developed. Unlike conventional fluorescence emission or excitation spectral measurements, synchronous fluorescence measurement offered exclusively a new synchronous fluorescence peak in the shorter wavelength range upon binding of chrysene with protein making it an easy identification tool for albumin determination. The cooperative binding of a fluorescence probe, chrysene, in a supramolecular host-protein assembly during various albumin assessments was investigated. The presence of supramolecular host molecules such as beta-cyclodextrin, curucurbit[6]uril or curucurbit[7]uril have little influence on sensitivity or limit of detection during albumin determination but reduced dramatically interference from various coexisting metal ion quenchers/enhancers. Using the present method the limit of detection for BSA and gamma-Globulin was found to be 0.005 microM which is more sensitive than reported values. Copyright 2009 Elsevier B.V. All rights reserved.

  12. Determination of 17alpha-ethynylestradiol, carbamazepine, diazepam, simvastatin, and oxybenzone in fish livers.

    PubMed

    Kwon, Jeong-Wook; Armbrust, Kevin L; Vidal-Dorsch, Doris; Bay, Steven M

    2009-01-01

    A method using liquid chromatography/tandem mass spectrometry (LC/MS/MS) was developed for the determination of 17alpha-ethynylestradiol in fish liver; a second method using LC/MS was developed for the determination of carbamazepine, diazepam, simvastatin, and oxybenzone in fish liver. The fish liver samples were extracted and cleaned up by using liquid-liquid extraction and solid-phase extraction before the extracts were analyzed by LC/MS or LC/MS/MS with electrospray negative and positive ionization. Recoveries of the 5 target compounds from spiked catfish liver ranged from 72 +/- 2 to 100 +/- 3%. Limits of quantification for the 5 compounds were between 4.2 and 12.3 ng/g (wet weight). Ten turbot (Pleuronichthys verticalis) liver samples were analyzed; levels of 17alpha-ethynylestradiol, carbamazepine, simvastatin, and oxybenzone were below the detection limits. Diazepam was detected in all 10 fish liver samples at concentrations ranging from 23 to 110 ng/g (wet weight).

  13. Hydrothermal synthesis and processing of hydrogen titanate nanotubes for nicotine electrochemical sensing

    NASA Astrophysics Data System (ADS)

    Mersal, Gaber A. M.; Mostafa, Nasser Y.; Omar, Abd-Elkader H.

    2017-08-01

    Hydrogen titanate nanotubes (HTNT) were prepared via acid washing of hydrothermally synthesized sodium titantate nanotube. HTNTs with diameters in the range 7-9 nm and length of several hundred nanometers were annealed at different temperatures and used to modify carbon paste electrode (CPE). Cyclic and square wave voltammetric techniques were used to investigate the behavior of nicotine at HTNT modified carbon paste electrode (HTNTCPE). The nicotine-oxidation reaction over HTNTCPE was irreversible and adsorption process is the rate determining step. HTNTs annealed at 500 °C showed the best response to nicotine. The nicotine concentration was determined at the ideal conditions by square wave voltammetry (SWV). The calibration was linear from 0.1 to 500.0 µmol l-1 with a correlation coefficient of 0.995. The detection limits were found to be 0.005 µmol l-1. The present HTNTCPE was used to the determination of nicotine in two cigarette brands and it showed outstanding performance with respect to detection limit and sensitivity.

  14. Determination of Residual Solvents in Linezolid by Static Headspace GC

    PubMed Central

    Feng, Xiao-Zhen; Han, Guo-Cheng; Qin, Jianhe; Yin, Shi-min; Chen, Zhencheng

    2016-01-01

    A headspace gas chromatographic method was developed for the determination of residual solvents in linezolid active substances. The solvents include petroleum ether (60–90°C), acetone, tetrahydrofuran, ethyl acetate, methanol, dichloromethane (DCM) and pyridine. The method showed the possibility to detect the tested solvents with a linear determination correlation coefficient (r) greater than 0.9995 except for petroleum ether (0.9980). The limits of detection ranged between 0.12 μg/mL (petroleum ether) and 3.56 μg/mL (DCM), and the limits of quantity ranged between 0.41 μg/mL (petroleum ether) and 11.86 μg/mL (DCM). The method achieved good accuracy (recoveries ranging from 92.8 to 102.5%) and precision for both run-to-run and day-to-day assay (relative standard deviation ranging from 0.4 to 1.3%) for all seven solvents concerned, which were applied in the quality control of three batches of linezolid successfully. PMID:26657409

  15. Precursor ion scan driven fast untargeted screening and semi-determination of caffeoylquinic acid derivatives in Cynara scolymus L.

    PubMed

    Shen, Qing; Lu, Yanbin; Dai, Zhiyuan; Cheung, Hon-Yeung

    2015-01-01

    A precursor ion scan (PIS) technique based strategy was developed for rapid screening and semi-determination of caffeoylquinic acid derivatives (CADs) in artichoke (Cynara scolymus L.) using ultra-performance liquid chromatography (UPLC) coupled with tandem mass spectrometry. 1,5-Dicaffeoylquinic acid and 5-caffeoylquinic acid were used for studying the fragmentation behaviour of two classes of CADs, setting m/z 191 as a diagnostic moiety. When it was applied to artichoke sample, ten CADs were detected and elucidated in a single PIS run. Furthermore, method validation was implemented including: specificity (no interference), linearity (≥0.9993), limit of detection (LOD<0.12 ng mL(-1)) and limit of quantification (LOQ<0.25 ng mL(-1)), precision (RSD≤3.6), recovery (91.4-95.9%) and stability (at least 12 h). This approach was proven to be a powerful, selective and sensitive tool for rapid screening and semi-determination of untargeted components in natural products. Copyright © 2014 Elsevier Ltd. All rights reserved.

  16. Method of analysis at the U.S. Geological Survey California Water Science Center, Sacramento Laboratory - determination of haloacetic acid formation potential, method validation, and quality-control practices

    USGS Publications Warehouse

    Zazzi, Barbara C.; Crepeau, Kathryn L.; Fram, Miranda S.; Bergamaschi, Brian A.

    2005-01-01

    An analytical method for the determination of haloacetic acid formation potential of water samples has been developed by the U.S. Geological Survey California Water Science Center Sacramento Laboratory. The haloacetic acid formation potential is measured by dosing water samples with chlorine under specified conditions of pH, temperature, incubation time, darkness, and residual-free chlorine. The haloacetic acids formed are bromochloroacetic acid, bromodichloroacetic acid, dibromochloroacetic acid, dibromoacetic acid, dichloroacetic acid, monobromoacetic acid, monochloroacetic acid, tribromoacetic acid, and trichloroacetic acid. They are extracted, methylated, and then analyzed using a gas chromatograph equipped with an electron capture detector. Method validation experiments were performed to determine the method accuracy, precision, and detection limit for each of the compounds. Method detection limits for these nine haloacetic acids ranged from 0.11 to 0.45 microgram per liter. Quality-control practices include the use of blanks, quality-control samples, calibration verification standards, surrogate recovery, internal standard, matrix spikes, and duplicates.

  17. A rapid and simple determination of caffeine in teas, coffees and eight beverages.

    PubMed

    Sereshti, Hassan; Samadi, Soheila

    2014-09-01

    Caffeine was extracted and preconcentrated by the simple, fast and green method of dispersive liquid-liquid microextraction (DLLME) and analysed by gas chromatography-nitrogen phosphorus detection (GC-NPD). The influence of main parameters affecting the extraction efficiency investigated and optimised. Under the optimal conditions, the method was successfully applied to determination of caffeine in different real samples including five types of tea (green, black, white, oolong teas and tea bag), two kinds of coffee (Nescafe coffee and coffee), and eight beverages (regular Coca Cola, Coca Cola zero, regular Pepsi, Pepsi max, Sprite, 7up, Red Bull and Hype).The limit of detection (LOD) and limit of quantification (LOQ) were 0.02 and 0.05 μg mL(-1), respectively. Linear dynamic range (LDR) was 0.05-500 μg mL(-1) and determination coefficient (R(2)) was 0.9990. The relative standard deviation (RSD) was 3.2% (n=5, C=1 μg mL(-1)). Copyright © 2014 Elsevier Ltd. All rights reserved.

  18. Determination of vigabatrin in plasma by reversed-phase high-performance liquid chromatography.

    PubMed

    Tsanaclis, L M; Wicks, J; Williams, J; Richens, A

    1991-05-01

    A method is described for the determination of vigabatrin in 50 microliters of plasma by isocratic high-performance liquid chromatography using fluorescence detection. The procedure involves protein precipitation with methanol followed by precolumn derivatisation with o-phthaldialdehyde reagent. Separation of the derivatised vigabatrin was achieved on a Microsorb C18 column using a mobile phase of 10 mM orthophosphoric acid:acetonitrile:methanol (6:3:1) at a flow rate of 2.0 ml/min. Assay time is 15 min and chromatograms show no interference from commonly coadministered anticonvulsant drugs. The total analytical error within the range of 0.85-85 micrograms/ml was found to be 7.6% with the within-replicates error of 2.76%. The minimum detection limit was 0.08 micrograms/ml and the minimum quantitation limit was 0.54 micrograms/ml.

  19. Far-infrared photometry of compact extragalactic objects - Detection of 3C 345

    NASA Technical Reports Server (NTRS)

    Harvey, P. M.; Wilking, B. A.; Joy, M.

    1982-01-01

    The first detection of a quasar between 10 and 1000 microns is reported. The observation permits (1) the determination of the intersection of the optical/infrared and millimeter continua; (2) more precise determination of the total luminosity; (3) the placing of limits on the contribution of any thermal dust emission to the total luminosity. The quasar is the first object ever to have been observed whose energy distribution peaks at wavelength of about 100 microns without a large contribution to the total luminosity from thermal dust emission. The observed flux density of 2.2 + or - 0.5 Jy at 100 microns and an upper limit of 0.5 + or - 0.6 Jy at 50 microns clearly define the overall energy distribution and show the quasar to be a powerful far-infrared source.

  20. Highly sensitive lidar with a thumb-sized sensor-head built using an optical fiber preamplifier

    NASA Astrophysics Data System (ADS)

    Inoue, Daisuke; Ichikawa, Tadashi; Matsubara, Hiroyuki; Mao, Xueon; Maeda, Mitsutoshi; Nagashima, Chie; Kagami, Manabu

    2011-06-01

    We developed a LIDAR system with a sensor head as small as 22 cc, in spite of the inclusion of a scanning mechanism. This LIDAR system not only has a small body, but is also highly sensitive. Our LIDAR system is based on time-of-flight measurements, and it incorporates an optical fiber. The main feature of our system is the utilization of optical amplifiers for both the transmitter and the receiver, and the optical amplifiers enabled us to exceed the detection limit of thermal noise. In conventional LIDAR systems the detection limit is determined by thermal noise, because the avalanche photo-diodes (APD) and trans-impedance amplifiers (TIA) that they use detect the received signals directly. In the case of our LIDAR system, received signal is amplified by an optical fiber amplifier in front of the photo diode and the TIA. Therefore, our LIDAR system can boost the signal level before the weak incoming signal is depleted by thermal noise. There are conditions under which the noise figure for the combination of an optical fiber amplifier and a photo diode is superior to the noise figure for an avalanche photo diode. We optimized the gain of the optical fiber amplifier and TIA in our LIDAR system such that it is capable of detecting a single photon. As a result, the detection limit of our LIDAR system is determined by shot noise. This small and highly sensitive measurement technology shows great potential for use in LIDAR with an optical preamplifier.

  1. Quantitative subpixel spectral detection of targets in multispectral images. [terrestrial and planetary surfaces

    NASA Technical Reports Server (NTRS)

    Sabol, Donald E., Jr.; Adams, John B.; Smith, Milton O.

    1992-01-01

    The conditions that affect the spectral detection of target materials at the subpixel scale are examined. Two levels of spectral mixture analysis for determining threshold detection limits of target materials in a spectral mixture are presented, the cases where the target is detected as: (1) a component of a spectral mixture (continuum threshold analysis) and (2) residuals (residual threshold analysis). The results of these two analyses are compared under various measurement conditions. The examples illustrate the general approach that can be used for evaluating the spectral detectability of terrestrial and planetary targets at the subpixel scale.

  2. Laser-Excited Atomic Fluorescence and Ionization in a Graphite Furnace for the Determination of Metals and Nonmetals

    NASA Astrophysics Data System (ADS)

    Butcher, David James

    1990-01-01

    Here is reported novel instrumentation for atomic spectrometry that combined the use of a pulsed laser system as the light source and an electrothermal atomizer as the atom cell. The main goal of the research was to develop instrumentation that was more sensitive for elemental analysis than commercially available instruments and could be used to determine elements in real sample matrices. Laser excited atomic fluorescence spectrometry (LEAFS) in an electrothermal atomizer (ETA) was compared to ETA atomic absorption spectrometry (AAS) for the determination of thallium, manganese, and lead in food and agricultural standard reference materials (SRMs). Compared to ETA AAS, ETA LEAFS has a longer linear dynamic range (LDR) (5-7 orders of magnitude compared to 2-3 orders of magnitude) and higher sensitivity (10 ^{-16} to 10^{ -14} g as compared to 10^{ -13} to 10^{-11} g). Consequently, ETA LEAFS allows elemental analysis to be done over a wider range of concentrations with less dilution steps. Thallium was accurately determined in biological samples by ETA LEAFS at amounts five to one hundred times below the ETA AAS detection limit. ETA AAS and ETA LEAFS were compared for the determination of lead and manganese, and in general, the accuracies and precisions of ETA AAS were the same, with typical precisions between 3% and 6%. Fluorine was determined using laser excited molecular fluorescence spectrometry (LEMOFS) in an ETA. Molecular fluorescence from magnesium fluoride was collected, and the detection limit of 0.3 pg fluorine was two to six orders of magnitude more sensitive than other methods commonly used for the determination of fluorine. Significant interferences from ions were observed, but the sensitivity was high enough that fluorine could be determined in freeze dried urine SRMs by diluting the samples by a factor of one hundred to remove the interferences. Laser enhanced ionization (LEI) in an ETA was used for the determination of metals. For thallium, indium, and lithium, detection limits between 0.7 and 2 pg were obtained, with an LDR of 3.5 orders of magnitude. Sodium was shown to severely depress the indium LEI signal in an ETA.

  3. A Portable, Low-Cost, LED Fluorimeter for Middle School, High School, and Undergraduate Chemistry Labs

    ERIC Educational Resources Information Center

    Wigton, Benjamin T.; Chohan, Balwant S.; McDonald, Cole; Johnson, Matt; Schunk, Doug; Kreuter, Rod; Sykes, Dan

    2011-01-01

    A low-cost portable fluorimeter was constructed using a 360 nm LED for excitation and a silicon photodiode for detection. The instrument is simple to operate and has been used to investigate fluorescent whitening agents extracted from various brands of paper, to determine the linear range and limit of detection of quinine in various commercial…

  4. Multi-residue method for the analysis of 85 current-use and legacy pesticides in bed and suspended sediments

    USGS Publications Warehouse

    Smalling, K.L.; Kuivila, K.M.

    2008-01-01

    A multi-residue method was developed for the simultaneous determination of 85 current-use and legacy organochlorine pesticides in a single sediment sample. After microwave-assisted extraction, clean-up of samples was optimized using gel permeation chromatography and either stacked carbon and alumina solid-phase extraction cartridges or a deactivated Florisil column. Analytes were determined by gas chromatography with ion-trap mass spectrometry and electron capture detection. Method detection limits ranged from 0.6 to 8.9 ??g/kg dry weight. Bed and suspended sediments from a variety of locations were analyzed to validate the method and 29 pesticides, including at least 1 from every class, were detected.

  5. Validation of APF as a Urinary Biomarker for Interstitial Cystitis

    DTIC Science & Technology

    2016-12-01

    using a CKAP4127-360 biosensor with sufficient binding efficiency to detect as-APF in urine with detection limits in the high nM to uM range. Urine...specimens from 14 (47%) of 30 women diagnosed with IC/PBS demonstrated as-APF binding activity to the CKAP4127-360 biosensor compared with 22 (73%) of 30...CKAP4 immobilized biosensor to detect APF (1-24 months) 2) Determine the ability of the SPR-based assay to detect APF in urine from patients with IC (1

  6. BRIEF REPORT: Screening Items to Identify Patients with Limited Health Literacy Skills

    PubMed Central

    Wallace, Lorraine S; Rogers, Edwin S; Roskos, Steven E; Holiday, David B; Weiss, Barry D

    2006-01-01

    BACKGROUND Patients with limited literacy skills are routinely encountered in clinical practice, but they are not always identified by clinicians. OBJECTIVE To evaluate 3 candidate questions to determine their accuracy in identifying patients with limited or marginal health literacy skills. METHODS We studied 305 English-speaking adults attending a university-based primary care clinic. Demographic items, health literacy screening questions, and the Rapid Estimate of Adult Literacy in Medicine (REALM) were administered to patients. To determine the accuracy of the candidate questions for identifying limited or marginal health literacy skills, we plotted area under the receiver operating characteristic (AUROC) curves for each item, using REALM scores as a reference standard. RESULTS The mean age of subjects was 49.5; 67.5% were female, 85.2% Caucasian, and 81.3% insured by TennCare and/or Medicare. Fifty-four (17.7%) had limited and 52 (17.0%) had marginal health literacy skills. One screening question, “How confident are you filling out medical forms by yourself?” was accurate in detecting limited (AUROC of 0.82; 95% confidence interval [CI]=0.77 to 0.86) and limited/marginal (AUROC of 0.79; 95% CI=0.74 to 0.83) health literacy skills. This question had significantly greater AUROC than either of the other questions (P<.01) and also a greater AUROC than questions based on demographic characteristics. CONCLUSIONS One screening question may be sufficient for detecting limited and marginal health literacy skills in clinic populations. PMID:16881950

  7. Construction of novel sensitive electrochemical sensor for electro-oxidation and determination of citalopram based on zinc oxide nanoparticles and multi-walled carbon nanotubes.

    PubMed

    Ghaedi, Hamed; Afkhami, Abbas; Madrakian, Tayyebeh; Soltani-Felehgari, Farzaneh

    2016-02-01

    A new chemically modified carbon paste electrode (CMCPE) was applied to the simple, rapid, highly selective and sensitive determination of citalopram in human serum and pharmaceutical preparations using adsorptive square wave voltammetry (ASWV). The ZnO nanoparticles and multi-walled carbon nanotubes modified CPE (ZnO-MWCNT/CPE) electrode was prepared by incorporation of the ZnO nanoparticles and multi-walled carbon nanotubes (MWCNT) in carbon paste electrode. The limit of detection and the linear range were found to be 0.005 and 0.012 to 1.54μmolL(-1) of citalopram, respectively. The effects of potentially interfering substances on the determination of this compound were investigated and found that the electrode is highly selective. The proposed CMCPE was used to the determination of citalopram in human serum, urine and pharmaceutical samples. This reveals that ZnO-MWCNT/CPE shows excellent analytical performance for the determination of citalopram in terms of very low detection limit, high sensitivity, very good repeatability and reproducibility over other methods reported in the literature. Copyright © 2015. Published by Elsevier B.V.

  8. Development and evaluation of a gas chromatographic method for the determination of triazine herbicides in natural water samples

    USGS Publications Warehouse

    Steinheimer, T.R.; Brooks, M.G.

    1984-01-01

    A multi-residue method is described for the determination of triazine herbicides in natural water samples. The technique uses solvent extraction followed by gas chromatographic separation and detection employing nitrogen-selective devices. Seven compounds can be determined simultaneously at a nominal detection limit of 0.1 ??g/L in a 1-litre sample. Three different natural water samples were used for error analysis via evaluation of recovery efficiencies and estimation of overall method precision. As an alternative to liquid-liquid partition (solvent extraction) for removal of compounds of interest from water, solid-phase extraction (SPE) techniques employing chromatographic grade silicas with chemically modified surfaces have been examined. SPE is found to provide rapid and efficient concentration with quantitative recovery of some triazine herbicides from natural water samples. Concentration factors of 500 to 1000 times are obtained readily by the SPE technique.A multi-residue method is described for the determination of triazine herbicides in natural water samples. The technique uses solvent extraction followed by gas chromatographic separation and detection employing nitrogen-selective devices. Seven compounds can be determined simultaneously at a nominal detection limit of 0. 1 mu g/L in a 1-litre sample. As an alternative to liquid-liquid partition (solvent extraction) for removal of compounds of interest from water, solid-phase extraction (SPE) techniques employing chromatographic grade silicas with chemically modified surfaces have been examined. SPE is found to provide rapid and efficient concentration with quantitative recovery of some triazine herbicides from natural water samples. Concentration factors of 500 to 1000 times are obtained readily by the SPE technique.

  9. The determination of psilocin and psilocybin in hallucinogenic mushrooms by HPLC utilizing a dual reagent acidic potassium permanganate and tris(2,2'-bipyridyl)ruthenium(II) chemiluminescence detection system.

    PubMed

    Anastos, Nicole; Lewis, Simon W; Barnett, Neil W; Sims, D Noel

    2006-01-01

    This paper describes a procedure for the determination of psilocin and psilocybin in mushroom extracts using high-performance liquid chromatography with postcolumn chemiluminescence detection. A number of extraction methods for psilocin and psilocybin in hallucinogenic mushrooms were investigated, with a simple methanolic extraction being found to be most effective. Psilocin and psilocybin were extracted from a variety of hallucinogenic mushrooms using methanol. The analytes were separated on a C12 column using a (95:5% v/v) methanol:10 mM ammonium formate, pH 3.5 mobile phase with a run time of 5 min. Detection was realized through a dual reagent chemiluminescence detection system of acidic potassium permanganate and tris(2,2'-bipyridyl)ruthenium(II). The chemiluminescence detection system gave improved detectability when compared with UV absorption at 269 nm, with detection limits of 1.2 x 10(-8) and 3.5 x 10(-9) mol/L being obtained for psilocin and psilocybin, respectively. The procedure was applied to the determination of psilocin and psilocybin in three Australian species of hallucinogenic mushroom.

  10. Azadinium Species Detection in Puget Sound, Washington State

    NASA Astrophysics Data System (ADS)

    Kelly, K. J.; Trainer, V. L.; Adams, N. G.

    2017-12-01

    Species of the genus Azadinium, including A. spinosum, A. obesum, and A. poporum, were first detected in Puget Sound, Washington State, in 2014. Azadinium spinosum and A. poporum are known to produce azaspiracids (AZAs), toxins that can cause a syndrome in humans known as azaspiracid shellfish poisoning. Symptoms following the ingestion of shellfish contaminated with AZAs include chills, headaches, diarrhea, nausea, vomiting, and stomach cramps. In our study conducted in summer 2017, seawater samples collected weekly at <8 sites and monthly at <31 sites in Puget Sound, were used to determine the presence, abundance, and distribution of Azadinium. Deoxyribose nucleic acid was extracted from filtered seawater samples, quantified, analyzed using quantitative polymerase chain reaction (qPCR) assays. Species-specific probes were used for the detection of A. poporum, A. obesum, and A. spinosum. If none of the three species were detected, the Amphidomataceae assay was used to determine whether other Azadinium species belonging to this family were present. Most samples were below the limit of detection for all three Azadinium species, however several samples had concentrations of cells that were detectable but below the limit of quantification. Concentrations of Azadinium poporum ranging from 5-76 cells/L were consistently detected at Quartermaster Harbor, Quilcene, and Sequim Bay, WA. Although Azadinium spp. were present only in low quantities during the period of our study, we demonstrated the effectiveness of routine analysis of seawater samples using specific qPCR assays to provide an early warning for potentially toxic Azadinium in Puget Sound.

  11. Metabolite profiling with HPLC-ICP-MS as a tool for in vivo characterization of imaging probes.

    PubMed

    Boros, Eszter; Pinkhasov, Omar R; Caravan, Peter

    2018-01-01

    Current analytical methods for characterizing pharmacokinetic and metabolic properties of positron emission tomography (PET) and single photon emission computed tomography (SPECT) probes are limited. Alternative methods to study tracer metabolism are needed. The study objective was to assess the potential of high performance liquid chromatography - inductively coupled plasma - mass spectrometry (HPLC-ICP-MS) for quantification of molecular probe metabolism and pharmacokinetics using stable isotopes. Two known peptide-DOTA conjugates were chelated with nat Ga and nat In. Limit of detection of HPLC-ICP-MS for 69 Ga and 115 In was determined. Rats were administered 50-150 nmol of Ga- and/or In-labeled probes, blood was serially sampled, and plasma analyzed by HPLC-ICP-MS using both reverse phase and size exclusion chromatography. The limits of detection were 0.16 pmol for 115 In and 0.53 pmol for 69 Ga. Metabolites as low as 0.001 %ID/g could be detected and transchelation products identified. Simultaneous administration of Ga- and In-labeled probes allowed the determination of pharmacokinetics and metabolism of both probes in a single animal. HPLC-ICP-MS is a robust, sensitive and radiation-free technique to characterize the pharmacokinetics and metabolism of imaging probes.

  12. Determination of Fe, Hg, Mn, and Pb in three-rings of poplar (Populus alba L.) by U-shaped DC arc

    NASA Astrophysics Data System (ADS)

    Marković, D. M.; Novović, I.; Vilotić, D.; Ignjatović, Lj.

    2007-09-01

    The U-shaped DC arc with aerosol supply was applied for the determination of Fe, Hg, Mn, and Pb in poplar (Populus alba L.) tree-rings. By optimization of the operating parameters and by selection of the most appropriate signal integration time (20 s for Fe, Mn, and Pb and 30 s for Hg), the obtained limits of detection for Fe, Hg, Mn, and Pb are 5.8, 2.6, 1.6, and 2.0 ng/ml, respectively. The detection limits achieved by this method for Fe, Hg, Mn, and Pb are comparable with the detection limits obtained for these elements by such methods as inductively coupled plasma-atomic emission spectrometry (ICP-AES), direct coupled plasmatomic emission spectrometry (DCP-AES), and microwave-induced plasma-atomic emission spectrometry (MIP-AES). We used the tree-rings of poplar from two different locations. The first one is in the area close to the power plant “Nikola Tesla” TENT A, Obrenovac, while the other one is in the urban area of Novi Sad. In almost all cases, samples from the location at Obrenovac registered elevated average concentrations of Fe, Hg, Mn, and Pb in the tree-rings of poplar.

  13. Determination of quinolones and fluoroquinolones, tetracyclines and sulfonamides in bovine, swine and poultry liver using LC-MS/MS.

    PubMed

    Martins, Magda Targa; Barreto, Fabiano; Hoff, Rodrigo Barcelos; Jank, Louise; Arsand, Juliana Bazzan; Feijó, Tiago Correa; Schapoval, Elfrides Eva Scherman

    2015-01-01

    Antibacterials are widely used in veterinary medicine. Residues of these drugs can remain in food of animal origin, including bovine liver. This paper describes a fast and simple analytical method for the determination of quinolones and fluoroquinolones, tetracyclines and sulfonamides in bovine liver samples. Deuterated enrofloxacin, sulfapyridine and demeclocycline were used as internal standards. The homogenised liver samples were extracted with acidified acetonitrile. Steps of non-solid-phase extraction (SPE) clean-up and concentration were used in the presented method. The final extracts were analysed by sensitive and selective detection of all components in a single run using LC-MS/MS. Acceptable recoveries between 66% and 110% were obtained. Good linearity (r(2)) above 0.96, considering three different days, for all drugs was achieved in concentrations ranging from 0.0 to 2.0 × the maximum residue limit (MRL). Intraday precision with coefficient of variation (CV%) (n = 6) lower than 14.7% and inter-day precision lower than 18.8% in agreement with European Commission Decision 2002/657/EC were obtained in concentrations ranging from 0.5 to 1.5 MRL. Accuracy was between 86% and 110%. Limits of detection and quantitation, as well as decision limit (CCα) and detection capability (CCβ), were also evaluated.

  14. Exploring laser-induced breakdown spectroscopy for nuclear materials analysis and in-situ applications

    NASA Astrophysics Data System (ADS)

    Martin, Madhavi Z.; Allman, Steve; Brice, Deanne J.; Martin, Rodger C.; Andre, Nicolas O.

    2012-08-01

    Laser-induced breakdown spectroscopy (LIBS) has been used to determine the limits of detection of strontium (Sr) and cesium (Cs), common nuclear fission products. Additionally, detection limits were determined for cerium (Ce), often used as a surrogate for radioactive plutonium in laboratory studies. Results were obtained using a laboratory instrument with a Nd:YAG laser at fundamental wavelength of 1064 nm, frequency doubled to 532 nm with energy of 50 mJ/pulse. The data was compared for different concentrations of Sr and Ce dispersed in a CaCO3 (white) and carbon (black) matrix. We have addressed the sampling errors, limits of detection, reproducibility, and accuracy of measurements as they relate to multivariate analysis in pellets that were doped with the different elements at various concentrations. These results demonstrate that LIBS technique is inherently well suited for in situ analysis of nuclear materials in hot cells. Three key advantages are evident: (1) small samples (mg) can be evaluated; (2) nuclear materials can be analyzed with minimal sample preparation; and (3) samples can be remotely analyzed very rapidly (ms-seconds). Our studies also show that the methods can be made quantitative. Very robust multivariate models have been used to provide quantitative measurement and statistical evaluation of complex materials derived from our previous research on wood and soil samples.

  15. Validation of a screening method for the simultaneous identification of fat-soluble and water-soluble vitamins (A, E, B1, B2 and B6) in an aqueous micellar medium of hexadecyltrimethylammonium chloride.

    PubMed

    León-Ruiz, V; Vera, S; San Andrés, M P

    2005-04-01

    Simultaneous determination of the fat-soluble vitamins A and E and the water-soluble vitamins B1, B2 and B6 has been carried using a screening method from fluorescence contour graphs. These graphs show different colour zones in relation to the fluorescence intensity measured for the pair of excitation/emission wavelengths. The identification of the corresponding excitation/emission wavelength zones allows the detection of different vitamins in an aqueous medium regardless of the fat or water solubility of each vitamin, owing to the presence of a surfactant which forms micelles in water at the used concentration (over the critical micelle concentration). The micelles dissolve very water insoluble compounds, such as fat-soluble vitamins, inside the aggregates. This approach avoids the use of organic solvents in determining these vitamins and offers the possibility of analysing fat- and water-soluble vitamins simultaneously. The method has been validated in terms of detection limit, cut-off limit, sensitivity, number of false positives, number of false negatives and uncertainty range. The detection limit is about microg L(-1). The screening method was applied to different samples such as pharmaceuticals, juices and isotonic drinks.

  16. Detection of adenoviruses in shellfish by means of conventional-PCR, nested-PCR, and integrated cell culture PCR (ICC/PCR).

    PubMed

    Rigotto, C; Sincero, T C M; Simões, C M O; Barardi, C R M

    2005-01-01

    We tested three PCR based methodologies to detect adenoviruses associated with cultivated oysters. Conventional-PCR, nested-PCR, and integrated cell culture-PCR (ICC/PCR) were first optimized using oysters seeded with know amounts of Adenovirus serotype 5 (Ad5). The maximum sensitivity for Ad5 detection was determined for each method, and then used to detect natural adenovirus contamination in oysters from three aquiculture farms in Florianopolis, Santa Catarina State, Brazil, over a period of 6 months. The results showed that the nested-PCR was more sensitive (limit of detection: 1.2 PFU/g of tissue) than conventional-PCR and ICC-PCR (limit of detection for both: 1.2 x 10(2)PFU/g of tissue) for detection of Ad5 in oyster extracts. Nested-PCR was able to detect 90% of Ad5 contamination in harvested oyster samples, while conventional-PCR was unable to detect Ad5 in any of the samples. The present work suggests that detection of human adenoviruses can be used as a tool to monitor the presence of human viruses in marine environments where shellfish grow, and that nested-PCR is the method of choice.

  17. Flow injection determination of aluminium by spectrofluorimetric detection after complexation with N-o-vanillidine-2-amino-p-cresol: the application to natural waters.

    PubMed

    Kara, Derya; Fisher, Andrew; Hill, Steve J

    2008-03-17

    An on-line flow injection spectrofluorimetric method for the direct determination of aluminium in water samples is described. The method is based on the reaction of aluminium with N-o-vanillidine-2-amino-p-cresol (OVAC) in acidic medium at pH 4.0 to form a water-soluble complex. The excitation and emission wavelengths were 423.0 and 553.0nm, respectively, at which the OVAC-Al complex gave the maximum fluorescence intensity at pH 4.0 in a 50% methanol-50% water medium at 50 degrees C. An interference from fluoride ions was minimised by the addition of Be(2+). Other ions were found not to interfere at the concentrations likely to be found in natural waters. The proposed methods were validated in terms of linearity, repeatability, detection limit, accuracy and selectivity. Under these conditions, the calibration was linear up to 1000microgL(-1) (r=0.999). The limit of detection (3sigma) for the determination of Al(III) was 0.057microgL(-1) and the precision for multiple determinations of 3ngmL(-1) Al(III) prepared in ultra-pure water was found to be 0.62% (n=10). The Schiff base ligand could be used to determine ultra-trace aluminium from natural waters. Analysis of environmental certified reference materials showed good agreement with the certified values. The procedure was found to be equally applicable to both freshwater and saline solutions, including seawater.

  18. Rapid Determination of Lymphogranuloma Venereum Serovars of Chlamydia trachomatis by Quantitative High-Resolution Melt Analysis (HRMA)

    PubMed Central

    Stevens, Matthew P.; Garland, Suzanne M.; Zaia, Angelo M.; Tabrizi, Sepehr N.

    2012-01-01

    A quantitative high-resolution melt analysis assay was developed to differentiate lymphogranuloma venereum-causing serovars of Chlamydia trachomatis (L1 to L3) from other C. trachomatis serovars (D to K). The detection limit of this assay is approximately 10 copies per reaction, comparable to the limits of other quantitative-PCR-based methods. PMID:22933594

  19. Polyamide as an efficient sorbent for simultaneous interface-free determination of three Sudan dyes in saffron and urine using high-performance liquid chromatography-ultra violet detection.

    PubMed

    Saeidi, Iman; Barfi, Behruz; Payrovi, Moazameh; Feizy, Javid; Sheibani, Hojat A; Miri, Mina; Ghollasi Moud, Farahnaz

    2015-01-01

    With polyamide (PA) as an efficient sorbent for solid phase extraction (SPE) of Sudan dyes II, III and Red 7B from saffron and urine, their determination by HPLC was performed. The optimum conditions for SPE were achieved using 7 mL methanol/water (1:9, v/v, pH 7) as the washing solvent and 3 mL tetrahydrofuran for elution. Good clean-up and high (above 90%) recoveries were observed for all the analytes. The optimized mobile phase composition for HPLC analysis of these compounds was methanol-water (70:30, v/v). The SPE parameters, such as the maximum loading capacity and breakthrough volume, were also determined for each analyte. The limits of detection (LODs), limits of quantification (LOQs), linear ranges and recoveries for the analytes were 4.6-6.6 microg/L, 13.0-19.8 microg/L, 13.0-5000 microg/L (r2>0.99) and 92.5%-113.4%, respectively. The precisions (RSDs) of the overall analytical procedure, estimated by five replicate measurements for Sudan II, III and Red 7B in saffron and urine samples were 2.3%, 1.8% and 3.6%, respectively. The developed method is simple and successful in the application to the determination of Sudan dyes in saffron and urine samples with HPLC coupled with UV detection.

  20. Analysis of Ag(I) Biocide in Water Samples Using Anodic Stripping Voltammetry with a Boron-Doped Diamond Disk Electrode.

    PubMed

    Maldonado, Vanessa Y; Espinoza-Montero, Patricio J; Rusinek, Cory A; Swain, Greg M

    2018-06-05

    The electroanalytical performance of a new commercial boron-doped diamond disk and a traditional nanocrystalline thin-film electrode were compared for the anodic stripping voltammetric determination of Ag(I). The diamond disk electrode is more flexible than the planar film as the former is compatible with most electrochemical cell designs including those incorporating magnetic stirring. Additionally, mechanical polishing and surface cleaning are simpler to execute. Differential pulse anodic stripping voltammetry (DPASV) was used to detect Ag(I) in standard solutions after optimization of the deposition potential, deposition time and scan rate. The optimized conditions were used to determine the concentration of Ag(I) in a NASA simulated potable water sample and a NIST standard reference solution. The electrochemical results were validated by ICP-OES measurements of the same solutions. The detection figures of merit for the disk electrode were as good or superior to those for the thin-film electrode. Detection limits were ≤5 μg L -1 (S/N = 3) for a 120 s deposition period, and response variabilities were <5% RSD. The polished disk electrode presented a more limited linear dynamic range presumably because of the reduced surface area available for metal phase formation. The concentrations of Ag(I) in the two water samples, as determined by DPASV, were in good agreement with the concentrations determined by ICP-OES.

  1. Simultaneous determination of nickel and copper by H-point standard addition method-first-order derivative spectrophotometry in plant samples after separation and preconcentration on modified natural clinoptilolite as a new sorbent.

    PubMed

    Roohparvar, Rasool; Taher, Mohammad Ali; Mohadesi, Alireza

    2008-01-01

    For the simultaneous determination of nickel(ll) and copper(ll) in plant samples, a rapid and accurate method was developed. In this method, solid-phase extraction (SPE) and first-order derivative spectrophotometry (FDS) are combined, and the result is coupled with the H-point standard addition method (HPSAM). Compared with normal spectrophotometry, derivative spectrophotometry offers the advantages of increased selectivity and sensitivity. As there is no need for carrying out any pretreatment of the sample, the spectrophotometry method is easy, but because of a high detection limit, it is not so practical. In order to decrease the detection limit, it is suggested to combine spectrophotometry with a preconcentration method such as SPE. In the present work, after separation and preconcentration of Ni(ll) and Cu(ll) on modified clinoptilolite zeolite that is loaded with 2-[1-(2-hydroxy-5-sulforphenyl)-3-phenyl-5-formaza-no]-benzoic acid monosodium salt (zincon) as a selective chromogenic reagent, FDS-HPSAM, which is a simple and selective spectrophotometric method, has been applied for simultaneous determination of these ions. With optimum conditions, the detection limit in original solutions is 0.7 and 0.5 ng/mL, respectively, for nickel and copper. The linear concentration ranges in the proposed method for nickel and copper ions in original solutions are 1.1 to 3.0 x 10(3) and 0.9 to 2.0 x 10(3) ng/mL, respectively. The recommended procedure is applied to successful determination of Cu(ll) and Ni(ll) in standard and real samples.

  2. Multiresidue analysis of sulfonamides in meat by supramolecular solvent microextraction, liquid chromatography and fluorescence detection and method validation according to the 2002/657/EC decision.

    PubMed

    Costi, Esther María; Sicilia, María Dolores; Rubio, Soledad

    2010-10-01

    A multiresidue method was described for determining eight sulfonamides, SAs (sulfadiazine, sulfamerazine, sulfamethoxypyridazine, sulfachloropyridazine, sulfadoxine, sulfamethoxazole, sulfadimethoxine and sulfaquinoxaline) in animal muscle tissues (pork, chicken, turkey, lamb and beef) at concentrations below the maximum residue limit (100 μg kg(-1)) set by the European Commission. The method was based on the microextraction of SAs in 300-mg muscle samples with 1 mL of a supramolecular solvent made up of reverse micelles of decanoic acid (DeA) and posterior determination of SAs in the extract by LC/fluorescence detection, after in situ derivatization with fluorescamine. Recoveries were quantitative (98-109%) and matrix-independent, no concentration of the extracts was required, the microextraction took about 30 min and several samples could be simultaneously treated. Formation of multiple hydrogen bonds between the carboxylic groups of the solvent and the target SAs (hydrogen donor and acceptor sum between 9 and 11) were considered as the major forces driving microextraction. The method was validated according to the European Union regulation 2002/657/EC. Analytical performance in terms of linearity, selectivity, trueness, precision, stability of SAs, decision limit and detection capability were determined. Quantitation limits for the different SAs ranged between 12 μg kg(-1) and 44 μg kg(-1), they being nearly independent of matrix composition. Repeatability and reproducibility, expressed as relative standard deviation, were in the ranges 1.8-3.6% and 3.3-6.1%. The results of the validation process proved that the method is suitable for determining sulfonamide residues in surveillance programs. Copyright © 2010 Elsevier B.V. All rights reserved.

  3. Optical biosensing of nitrite ions using cytochrome cd1 nitrite reductase encapsulated in a sol-gel matrix.

    PubMed

    Ferretti, S; Lee, S K; MacCraith, B D; Oliva, A G; Richardson, D J; Russell, D A; Sapsford, K E; Vidal, M

    2000-11-01

    Nitrite is an important human health and environmental analyte. As such, the European Union (EU) has imposed a limit for nitrite in potable water of 0.1 mg l-1 (2.18 microM). In order to develop an optical biosensing system for the determination of nitrite ions in environmental waters, cytochrome cd1 nitrite reductase has been extracted and purified from the bacterium Paracoccus pantotrophus. The protein has been spectroscopically characterised in solution and important kinetic parameters of nitrite reduction of the cytochrome cd1 enzyme, i.e., Km, Vmax and kcat have been determined. The influence of pH on the activity of the cytochrome cd1 has been investigated and the results suggest that this enzyme can be used for the determination of nitrite in the pH range 6-9. Biosensing experiments with the cytochrome cd1 in solution suggested that the decrease in intensity of the absorption band associated with the d1 haem (which is the nitrite binding site), at 460 nm, with increasing nitrite concentrations would enable the measurement of this analyte with the optimum limit of detection. The cytochrome cd1 has been encapsulated in a bulk sol-gel monolith with no structural changes observed and retention of enzymatic activity. The detection of nitrite ions in the range 0.075-1.250 microM was achieved, with a limit of detection of 0.075 microM. In order to increase the speed of response, a sol-gel sandwich thin film structure was formulated with the cytochrome cd1. This structure enabled the determination of nitrite concentrations within ca. 5 min. The sol-gel sandwich entrapped cytochrome cd1 enzyme was found to be stable for several months when the films were stored at 4 degrees C.

  4. Determination of organic peroxides by liquid chromatography with on-line post-column ultraviolet irradiation and peroxyoxalate chemiluminescence detection.

    PubMed

    Wada, Mitsuhiro; Inoue, Keiyu; Thara, Ayuko; Kishikawa, Naoya; Nakashima, Kenichiro; Kuroda, Naotaka

    2003-02-14

    A HPLC method was developed for the simultaneous determination of organic peroxides and hydrogen peroxide with peroxyoxalate chemiluminescence (PO-CL) detection following on-line UV irradiation. Organic peroxides [i.e., benzoyl peroxide (BP), tert.-butyl hydroperoxide (BHP), tert.-butyl perbenzoate (BPB), cumene hydroperoxide (CHP)] were UV irradiated (254 nm, 15 W) to generate hydrogen peroxide, which was determined by PO-CL detection. The conditions for UV irradiation and PO-CL detection were optimized by a flow injection analysis (FIA) system. Generation of hydrogen peroxide from peroxides with on-line UV irradiation also was confirmed by the FIA system by incorporating an enzyme column reactor immobilized with catalase. The separation of four organic peroxides and hydrogen peroxide by HPLC was accomplished isocratically on an ODS column within 30 min. The detection limits (signal-to-noise ratio=3) were 1.1 microM for hydrogen peroxide, 6.8 microM for BP, 31.3 microM for BHP, 7.5 microM for BPB and 1.3 microM for CHP. The proposed method was applied to the determination of BP in wheat flour.

  5. A STATISTICAL SURVEY OF DIOXIN-LIKE COMPOUNDS IN ...

    EPA Pesticide Factsheets

    The USEPA and the USDA completed the first statistically designed survey of the occurrence and concentration of dibenzo-p-dioxins (CDDs), dibenzofurans (CDFs), and coplanar polychlorinated biphenyls (PCBs) in the fat of beef animals raised for human consumption in the United States. Back fat was sampled from 63 carcasses at federally inspected slaughter establishments nationwide. The sample design called for sampling beef animal classes in proportion to national annual slaughter statistics. All samples were analyzed using a modification of EPA method 1613, using isotope dilution, High Resolution GC/MS to determine the rate of occurrence of 2,3,7,8-substituted CDDs/CDFs/PCBs. The method detection limits ranged from 0.05 ng/kg for TCDD to 3 ng/kg for OCDD. The results of this survey showed a mean concentration (reported as I-TEQ, lipid adjusted) in U.S. beef animals of 0.35 ng/kg and 0.89 ng/kg for CDD/CDF TEQs when either non-detects are treated as 0 value or assigned a value of 1/2 the detection limit, respectively, and 0.51 ng/kg for coplanar PCB TEQs at both non-detect equal 0 and 1/2 detection limit. journal article

  6. A practical approach to tramway track condition monitoring: vertical track defects detection and identification using time-frequency processing technique

    NASA Astrophysics Data System (ADS)

    Bocz, Péter; Vinkó, Ákos; Posgay, Zoltán

    2018-03-01

    This paper presents an automatic method for detecting vertical track irregularities on tramway operation using acceleration measurements on trams. For monitoring of tramway tracks, an unconventional measurement setup is developed, which records the data of 3-axes wireless accelerometers mounted on wheel discs. Accelerations are processed to obtain the vertical track irregularities to determine whether the track needs to be repaired. The automatic detection algorithm is based on time-frequency distribution analysis and determines the defect locations. Admissible limits (thresholds) are given for detecting moderate and severe defects using statistical analysis. The method was validated on frequented tram lines in Budapest and accurately detected severe defects with a hit rate of 100%, with no false alarms. The methodology is also sensitive to moderate and small rail surface defects at the low operational speed.

  7. Method validation for the determination of ochratoxin A in green and soluble coffee by immunoaffinity column cleanup and liquid chromatography.

    PubMed

    Diaz, G J; Ariza, D; Perilla, N S

    2004-06-01

    A method was validated for the determination of ochratoxin A (OTA) in soluble and green coffee. Performance parameters evaluated included selectivity, accuracy, intermediate precision, linearity, limit of detection, limit of quantitation, and ruggedness. The method was found to be selective for OTA in both matrices tested. Recovery rates from soluble coffee samples ranged from 73.5 to 91.2%, and from green coffee samples from 68.7 to 84.5%. The intermediate precision (RSDr) was between 9.1 and 9.4% for soluble coffee and between 14.3 and 15.5% for green coffee analysis. The linearity of the standard calibration curve (r(2)) was <0.999 for OTA levels of 1.0-20.0 μg/kg in coffee samples. The limit of detection was determined to be 0.01 ng of OTA on column, while the limit of quantitation was found to be 0.03 ng on column. The limit of quantitation is equivalent to 0.6 μg/kg in soluble coffee samples and 0.3 μg/kg in green coffee samples. The results of the ruggedness trial showed two factors are critical for soluble coffee analysis: the extraction method, and the flow rate of the mobile phase. For green coffee analysis two critical factors detected were the extraction method and the storage temperature of the immunoaffinity column.Five samples of soluble coffee and 42 of green coffee were analysed using the validated method. All soluble coffee samples contained OTA at levels that ranged from 8.4 to 13.9 μg/kg. Six of the 42 green coffee samples analysed (14.3%) contained OTA at levels ranging from 0.9 to 19.4 μg/kg. The validated method can be used to monitor OTA levels in Colombian coffee for export or for local consumption.

  8. Detection of MPLW515L/K Mutations and Determination of Allele Frequencies with a Single-Tube PCR Assay

    PubMed Central

    Takei, Hiraku; Morishita, Soji; Araki, Marito; Edahiro, Yoko; Sunami, Yoshitaka; Hironaka, Yumi; Noda, Naohiro; Sekiguchi, Yuji; Tsuneda, Satoshi; Ohsaka, Akimichi; Komatsu, Norio

    2014-01-01

    A gain-of-function mutation in the myeloproliferative leukemia virus (MPL) gene, which encodes the thrombopoietin receptor, has been identified in patients with essential thrombocythemia and primary myelofibrosis, subgroups of classic myeloproliferative neoplasms (MPNs). The presence of MPL gene mutations is a critical diagnostic criterion for these diseases. Here, we developed a rapid, simple, and cost-effective method of detecting two major MPL mutations, MPLW515L/K, in a single PCR assay; we termed this method DARMS (dual amplification refractory mutation system)-PCR. DARMS-PCR is designed to produce three different PCR products corresponding to MPLW515L, MPLW515K, and all MPL alleles. The amplicons are later detected and quantified using a capillary sequencer to determine the relative frequencies of the mutant and wild-type alleles. Applying DARMS-PCR to human specimens, we successfully identified MPL mutations in MPN patients, with the exception of patients bearing mutant allele frequencies below the detection limit (5%) of this method. The MPL mutant allele frequencies determined using DARMS-PCR correlated strongly with the values determined using deep sequencing. Thus, we demonstrated the potential of DARMS-PCR to detect MPL mutations and determine the allele frequencies in a timely and cost-effective manner. PMID:25144224

  9. Detection of MPLW515L/K mutations and determination of allele frequencies with a single-tube PCR assay.

    PubMed

    Takei, Hiraku; Morishita, Soji; Araki, Marito; Edahiro, Yoko; Sunami, Yoshitaka; Hironaka, Yumi; Noda, Naohiro; Sekiguchi, Yuji; Tsuneda, Satoshi; Ohsaka, Akimichi; Komatsu, Norio

    2014-01-01

    A gain-of-function mutation in the myeloproliferative leukemia virus (MPL) gene, which encodes the thrombopoietin receptor, has been identified in patients with essential thrombocythemia and primary myelofibrosis, subgroups of classic myeloproliferative neoplasms (MPNs). The presence of MPL gene mutations is a critical diagnostic criterion for these diseases. Here, we developed a rapid, simple, and cost-effective method of detecting two major MPL mutations, MPLW515L/K, in a single PCR assay; we termed this method DARMS (dual amplification refractory mutation system)-PCR. DARMS-PCR is designed to produce three different PCR products corresponding to MPLW515L, MPLW515K, and all MPL alleles. The amplicons are later detected and quantified using a capillary sequencer to determine the relative frequencies of the mutant and wild-type alleles. Applying DARMS-PCR to human specimens, we successfully identified MPL mutations in MPN patients, with the exception of patients bearing mutant allele frequencies below the detection limit (5%) of this method. The MPL mutant allele frequencies determined using DARMS-PCR correlated strongly with the values determined using deep sequencing. Thus, we demonstrated the potential of DARMS-PCR to detect MPL mutations and determine the allele frequencies in a timely and cost-effective manner.

  10. Calculating the ankylosing spondylitis disease activity score if the conventional c-reactive protein level is below the limit of detection or if high-sensitivity c-reactive protein is used: an analysis in the DESIR cohort.

    PubMed

    Machado, Pedro; Navarro-Compán, Victoria; Landewé, Robert; van Gaalen, Floris A; Roux, Christian; van der Heijde, Désirée

    2015-02-01

    The Ankylosing Spondylitis Disease Activity Score (ASDAS) is a composite measure of disease activity in axial spondyloarthritis. The aims of this study were to determine the most appropriate method for calculating the ASDAS using the C-reactive protein (CRP) level when the conventional CRP level was below the limit of detection, to determine how low CRP values obtained by high-sensitivity CRP (hsCRP) measurement influence ASDAS-CRP results, and to test agreement between different ASDAS formulae. Patients with axial spondyloarthritis who had a conventional CRP level below the limit of detection (5 mg/liter) were selected (n = 257). The ASDAS–conventional CRP with 11 different imputations for the conventional CRP value (range 0–5 mg/liter, at 0.5-mg/liter intervals) was calculated. The ASDAS-hsCRP and ASDAS using the erythrocyte sedimentation rate (ESR) were also calculated. Agreement between the ASDAS formulae was tested. The ASDAS-hsCRP showed better agreement with the ASDAS-CRP calculated using the conventional CRP imputation values of 1.5 and 2.0 mg/liter and with the ASDAS-ESR than with other imputed formulae. Disagreement occurred mainly in lower disease activity states (inactive/moderate disease activity). When the CRP value was <2 mg/liter, the resulting ASDAS-CRP scores may have been inappropriately low. When the conventional CRP level is below the limit of detection or when the hsCRP level is <2 mg/liter, the constant value of 2 mg/liter should be used to calculate the ASDAS-CRP score. There is good agreement between the ASDAS-hsCRP and ASDAS-ESR; however, formulae are not interchangeable.

  11. Lactoferrin Isolation Using Monolithic Column Coupled with Spectrometric or Micro-Amperometric Detector

    PubMed Central

    Adam, Vojtech; Zitka, Ondrej; Dolezal, Petr; Zeman, Ladislav; Horna, Ales; Hubalek, Jaromir; Sileny, Jan; Krizkova, Sona; Trnkova, Libuse; Kizek, Rene

    2008-01-01

    Lactoferrin is a multifunctional protein with antimicrobial activity and others to health beneficial properties. The main aim of this work was to propose easy to use technique for lactoferrin isolation from cow colostrum samples. Primarily we utilized sodium dodecyl sulphate – polyacrylamide gel electrophoresis for isolation of lactoferrin from the real samples. Moreover we tested automated microfluidic Experion electrophoresis system to isolate lactoferrin from the collostrum sample. The well developed signal of lactoferrin was determined with detection limit (3 S/N) of 20 ng/ml. In spite of the fact that Experion is faster than SDS-PAGE both separation techniques cannot be used in routine analysis. Therefore we have tested third separation technique, ion exchange chromatography, using monolithic column coupled with UV-VIS detector (LC-UV-VIS). We optimized wave length (280 nm), ionic strength of the elution solution (1.5 M NaCl) and flow rate of the retention and elution solutions (0.25 ml/min and 0.75 ml/min. respectively). Under the optimal conditions the detection limit was estimated as 0.1 μg/ml of lactoferrin measured. Using LC-UV-VIS we determined that lactoferrin concentration varied from 0.5 g/l to 1.1 g/l in cow colostrums collected in the certain time interval up to 72 hours after birth. Further we focused on miniaturization of detection device. We tested amperometric detection at carbon electrode. The results encouraged us to attempt to miniaturise whole detection system and to test it on analysis of real samples of human faeces, because lactoferrin level in faeces is closely associated with the inflammations of intestine mucous membrane. For the purpose of miniaturization we employed the technology of printed electrodes. The detection limit of lactoferrin was estimated as 10 μg/ml measured by the screen-printed electrodes fabricated by us. The fabricated electrodes were compared with commercially available ones. It follows from the obtained results that the responses measured by commercial electrodes are app. ten times higher compared with those measured by the electrodes fabricated by us. This phenomenon relates with smaller working electrode surface area of the electrodes fabricated by us (about 50 %) compared to the commercial ones. The screen-printed electrodes fabricated by us were utilized for determination of lactoferrin faeces. Regarding to fact that sample of faeces was obtained from young and healthy man the amount of lactoferrin in sample was under the limit of detection of this method. PMID:27879717

  12. Colorimetric detection of cholesterol based on enzyme modified gold nanoparticles

    NASA Astrophysics Data System (ADS)

    Nirala, Narsingh R.; Saxena, Preeti S.; Srivastava, Anchal

    2018-02-01

    We develop a simple colorimetric method for determination of free cholesterol in aqueous solution based on functionalized gold nanoparticles with cholesterol oxidase. Functionalized gold nanoparticles interact with free cholesterol to produce H2O2 in proportion to the level of cholesterol visually is being detected. The quenching in optical properties and agglomeration of functionalized gold nanoparticles play a key role in cholesterol sensing due to the electron accepting property of H2O2. While the lower ranges of cholesterol (lower detection limit i.e. 0.2 mg/dL) can be effectively detected using fluorescence study, the absorption study attests evident visual color change which becomes effective for detection of higher ranges of cholesterol (lower detection limit i.e. 19 mg/dL). The shades of red gradually change to blue/purple as the level of cholesterol detected (as evident at 100 mg/dL) using unaided eye without the use of expensive instruments. The potential of the proposed method to be applied in the field is shown by the proposed cholesterol measuring color wheel.

  13. New diagnostics for melanoma detection: from artificial intelligence to RNA microarrays.

    PubMed

    Ahlgrimm-Siess, Verena; Laimer, Martin; Arzberger, Edith; Hofmann-Wellenhof, Rainer

    2012-07-01

    Early detection of melanoma remains crucial to ensuring a favorable prognosis. Dermoscopy and total body photography are well-established noninvasive aids that increase the diagnostic accuracy of dermatologists in their daily routine, beyond that of a naked-eye examination. New noninvasive diagnostic techniques, such as reflectance confocal microscopy, multispectral digital imaging and RNA microarrays, are currently being investigated to determine their utility for melanoma detection. This review presents emerging technologies for noninvasive melanoma diagnosis, and discusses their advantages and limitations.

  14. Targeted Analyte Detection by Standard Addition Improves Detection Limits in MALDI Mass Spectrometry

    PubMed Central

    Eshghi, Shadi Toghi; Li, Xingde; Zhang, Hui

    2014-01-01

    Matrix-assisted laser desorption/ionization has proven an effective tool for fast and accurate determination of many molecules. However, the detector sensitivity and chemical noise compromise the detection of many invaluable low-abundance molecules from biological and clinical samples. To challenge this limitation, we developed a targeted analyte detection (TAD) technique. In TAD, the target analyte is selectively elevated by spiking a known amount of that analyte into the sample, thereby raising its concentration above the noise level, where we take advantage of the improved sensitivity to detect the presence of the endogenous analyte in the sample. We assessed TAD on three peptides in simple and complex background solutions with various exogenous analyte concentrations in two MALDI matrices. TAD successfully improved the limit of detection (LOD) of target analytes when the target peptides were added to the sample in a concentration close to optimum concentration. The optimum exogenous concentration was estimated through a quantitative method to be approximately equal to the original LOD for each target. Also, we showed that TAD could achieve LOD improvements on an average of 3-fold in a simple and 2-fold in a complex sample. TAD provides a straightforward assay to improve the LOD of generic target analytes without the need for costly hardware modifications. PMID:22877355

  15. Targeted analyte detection by standard addition improves detection limits in matrix-assisted laser desorption/ionization mass spectrometry.

    PubMed

    Toghi Eshghi, Shadi; Li, Xingde; Zhang, Hui

    2012-09-18

    Matrix-assisted laser desorption/ionization (MALDI) has proven an effective tool for fast and accurate determination of many molecules. However, the detector sensitivity and chemical noise compromise the detection of many invaluable low-abundance molecules from biological and clinical samples. To challenge this limitation, we developed a targeted analyte detection (TAD) technique. In TAD, the target analyte is selectively elevated by spiking a known amount of that analyte into the sample, thereby raising its concentration above the noise level, where we take advantage of the improved sensitivity to detect the presence of the endogenous analyte in the sample. We assessed TAD on three peptides in simple and complex background solutions with various exogenous analyte concentrations in two MALDI matrices. TAD successfully improved the limit of detection (LOD) of target analytes when the target peptides were added to the sample in a concentration close to optimum concentration. The optimum exogenous concentration was estimated through a quantitative method to be approximately equal to the original LOD for each target. Also, we showed that TAD could achieve LOD improvements on an average of 3-fold in a simple and 2-fold in a complex sample. TAD provides a straightforward assay to improve the LOD of generic target analytes without the need for costly hardware modifications.

  16. Comparison of two microextraction methods based on solidification of floating organic droplet for the determination of multiclass analytes in river water samples by liquid chromatography tandem mass spectrometry using Central Composite Design.

    PubMed

    Asati, Ankita; Satyanarayana, G N V; Patel, Devendra K

    2017-09-01

    Two low density organic solvents based liquid-liquid microextraction methods, namely Vortex assisted liquid-liquid microextraction based on solidification of floating organic droplet (VALLME-SFO) and Dispersive liquid-liquid microextraction based on solidification of floating organic droplet(DLLME-SFO) have been compared for the determination of multiclass analytes (pesticides, plasticizers, pharmaceuticals and personal care products) in river water samples by using liquid chromatography tandem mass spectrometry (LC-MS/MS). The effect of various experimental parameters on the efficiency of the two methods and their optimum values were studied with the aid of Central Composite Design (CCD) and Response Surface Methodology(RSM). Under optimal conditions, VALLME-SFO was validated in terms of limit of detection, limit of quantification, dynamic linearity range, determination of coefficient, enrichment factor and extraction recovery for which the respective values were (0.011-0.219ngmL -1 ), (0.035-0.723ngmL -1 ), (0.050-0.500ngmL -1 ), (R 2 =0.992-0.999), (40-56), (80-106%). However, when the DLLME-SFO method was validated under optimal conditions, the range of values of limit of detection, limit of quantification, dynamic linearity range, determination of coefficient, enrichment factor and extraction recovery were (0.025-0.377ngmL -1 ), (0.083-1.256ngmL -1 ), (0.100-1.000ngmL -1 ), (R 2 =0.990-0.999), (35-49), (69-98%) respectively. Interday and intraday precisions were calculated as percent relative standard deviation (%RSD) and the values were ≤15% for VALLME-SFO and DLLME-SFO methods. Both methods were successfully applied for determining multiclass analytes in river water samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Plutonium and uranium determination in environmental samples: combined solvent extraction-liquid scintillation method.

    PubMed

    McDowell, W J; Farrar, D T; Billings, M R

    1974-12-01

    A method for the determination of uranium and plutonium by a combined high-resolution liquid scintillation-solvent extraction method is presented. Assuming a sample count equal to background count to be the detection limit, the lower detection limit for these and other alpha-emitting nuclides is 1.0 dpm with a Pyrex sample tube, 0.3 dpm with a quartz sample tube using present detector shielding or 0.02 d.p.m. with pulse-shape discrimination. Alpha-counting efficiency is 100%. With the counting data presented as an alpha-energy spectrum, an energy resolution of 0.2-0.3 MeV peak half-width and an energy identification to +/-0.1 MeV are possible. Thus, within these limits, identification and quantitative determination of a specific alpha-emitter, independent of chemical separation, are possible. The separation procedure allows greater than 98% recovery of uranium and plutonium from solution containing large amounts of iron and other interfering substances. In most cases uranium, even when present in 10(8)-fold molar ratio, may be quantitatively separated from plutonium without loss of the plutonium. Potential applications of this general analytical concept to other alpha-counting problems are noted. Special problems associated with the determination of plutonium in soil and water samples are discussed. Results of tests to determine the pulse-height and energy-resolution characteristics of several scintillators are presented. Construction of the high-resolution liquid scintillation detector is described.

  18. Spiroguanidine rhodamines as fluorogenic probes for lysophosphatidic acid

    PubMed Central

    Wang, Lei; Sibrian-Vazquez, Martha; Escobedo, Jorge O.; Wang, Jialu; Moore, Richard G.

    2015-01-01

    Direct determination of total lysophosphatidic acid (LPA) was accomplished using newly developed spiroguanidines derived from rhodamine B as universal fluorogenic probes. Optimum conditions for the quantitative analysis of total LPA were investigated. The linear range for the determination of total LPA is up to 5 μM with a limit of detection of 0.512 μM. PMID:25516957

  19. Determination of Mercury in Milk by Cold Vapor Atomic Fluorescence: A Green Analytical Chemistry Laboratory Experiment

    ERIC Educational Resources Information Center

    Armenta, Sergio; de la Guardia, Miguel

    2011-01-01

    Green analytical chemistry principles were introduced to undergraduate students in a laboratory experiment focused on determining the mercury concentration in cow and goat milk. In addition to traditional goals, such as accuracy, precision, sensitivity, and limits of detection in method selection and development, attention was paid to the…

  20. Comparative Evaluation of Four Real-Time PCR Methods for the Quantitative Detection of Epstein-Barr Virus from Whole Blood Specimens.

    PubMed

    Buelow, Daelynn; Sun, Yilun; Tang, Li; Gu, Zhengming; Pounds, Stanley; Hayden, Randall

    2016-07-01

    Monitoring of Epstein-Barr virus (EBV) load in immunocompromised patients has become integral to their care. An increasing number of reagents are available for quantitative detection of EBV; however, there are little published comparative data. Four real-time PCR systems (one using laboratory-developed reagents and three using analyte-specific reagents) were compared with one another for detection of EBV from whole blood. Whole blood specimens seeded with EBV were used to determine quantitative linearity, analytical measurement range, lower limit of detection, and CV for each assay. Retrospective testing of 198 clinical samples was performed in parallel with all methods; results were compared to determine relative quantitative and qualitative performance. All assays showed similar performance. No significant difference was found in limit of detection (3.12-3.49 log10 copies/mL; P = 0.37). A strong qualitative correlation was seen with all assays that used clinical samples (positive detection rates of 89.5%-95.8%). Quantitative correlation of clinical samples across assays was also seen in pairwise regression analysis, with R(2) ranging from 0.83 to 0.95. Normalizing clinical sample results to IU/mL did not alter the quantitative correlation between assays. Quantitative EBV detection by real-time PCR can be performed over a wide linear dynamic range, using three different commercially available reagents and laboratory-developed methods. EBV was detected with comparable sensitivity and quantitative correlation for all assays. Copyright © 2016 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.

  1. Rare Earth Optical Temperature Sensor

    NASA Technical Reports Server (NTRS)

    Chubb, Donald L.; Wolford, David S.

    2000-01-01

    A new optical temperature sensor suitable for high temperatures (greater than 1700 K) and harsh environments is introduced. The key component of the sensor is the rare earth material contained at the end of a sensor that is in contact with the sample being measured. The measured narrow wavelength band emission from the rare earth is used to deduce the sample temperature. A simplified relation between the temperature and measured radiation was verified experimentally. The upper temperature limit of the sensor is determined by material limits to be approximately 2000 C. The lower limit, determined by the minimum detectable radiation, is found to be approximately 700 K. At high temperatures 1 K resolution is predicted. Also, millisecond response times are calculated.

  2. Determination of aldehydes and ketones using derivatization with 2,4-dinitrophenylhydrazine and liquid chromatography-atmospheric pressure photoionization-mass spectrometry.

    PubMed

    van Leeuwen, Suze M; Hendriksen, Laurens; Karst, Uwe

    2004-11-26

    Atmospheric pressure photoionization-mass spectrometry (APPI-MS) is used for the analysis of aldehydes and ketones after derivatization with 2,4-dinitrophenylhydrazine (DNPH) and liquid chromatographic separation. In the negative ion mode, the [M - H]- pseudomolecular ions are most abundant for the carbonyls. Compared with the established atmospheric pressure chemical ionization (APCI)-MS, limits of detection are typically lower using similar conditions. Automobile exhaust and cigarette exhaust samples were analyzed with APPI-MS and APCI-MS in combination with an ion trap mass analyzer. Due to improved limits of detection, more of the less abundant long-chain carbonyls are detected with APPI-MS in real samples. While 2,4-dinitrophenylazide, a known reaction product of DNPH with nitrogen dioxide, is detected in APCI-MS due to dissociative electron capture, it is not observed at all in APPI-MS.

  3. Levels of organophosphorus pesticides in medicinal plants commonly consumed in Iran

    PubMed Central

    2012-01-01

    The frequent occurrence of pesticide residues in herbal materials was indicated by previous studies. In this study, the concentration of some of the organophosphorus pesticides including parathion, malathion, diazinon and pirimiphos methyl in different kinds of medicinal plants were determined. The samples were collected randomly from ten local markets of different areas of Iran. At the detection limit of 0.5 ng g-1, parathion and pirimiphos methyl were not detected in any of the samples. Some amounts of malathion and diazinon were found in Zataria, Matricaria chamomile, Spearmint and Cumin Seed samples while, the concentrations of target organophosphorus pesticides in Borage samples were below the detection limits of the methods which could be a result of intensive transformation of organophosphorus pesticides by Borage. In addition the organophosphorus pesticides were detected in all of the samples below the maximum residue levels (MRLs) proposed by the international organizations. PMID:23351610

  4. Development of an Electrochemical Immunosensor for Fumonisins Detection in Foods

    PubMed Central

    Kadir, Mohamad Kamal Abdul; Tothill, Ibtisam E.

    2010-01-01

    An electrochemical affinity sensor for the determination of fumonisins mycotoxins (Fms) using monoclonal antibody modified screen-printed gold electrode with carbon counter and silver-silver chloride pseudo-reference electrode is reported in this work. A direct competitive enzyme-linked immunosorbent assay (ELISA) was initially developed, exhibiting a detection limit of 100 µg·L-1 for fumonisins. This was then transferred to the surface of a bare gold screen-printed electrode (SPGE) and detection was performed by chronoamperometry, monitoring the reaction of 3,3’,5,5’-Tetramethylbenzidine dihydrochloride (TMB) and hydrogen peroxide (H2O2) catalysed by HRP at −100 mV potential vs. onboard Ag-AgCl pseudo-reference electrode. The immunosensor exhibited detection limit of 5 µg·L−1 fumonisins with a dynamic range from 1 µg·L−1–1000 µg·L−1. The sensor also performed well in extracted corn samples. PMID:22069591

  5. Competitive immunoassay of phenobarbital by microchip electrophoresis with laser induced fluorescence detection.

    PubMed

    Huang, Yong; Zhao, Shulin; Shi, Ming; Liu, Jinwen; Liang, Hong

    2011-05-23

    A microchip electrophoresis method with laser induced fluorescence detection was developed for the immunoassay of phenobarbital. The detection was based on the competitive immunoreaction between analyte phenobarbital and fluorescein isothiocyanate (FITC) labeled phenobarbital with a limited amount of antibody. The assay was developed by varying the borate concentration, buffer pH, separation voltage, and incubation time. A running buffer system containing 35 mM borate and 15 mM sodium dodecyl sulfate (pH 9.5), and 2800 V separation voltage provided analysis conditions for a high-resolution, sensitive, and repeatable assay of phenobarbital. Free FITC-labeled phenobarbital and immunocomplex were separated within 30s. The calibration curve for phenobarbital had a detection limit of 3.4 nM and a range of 8.6-860.0 nM. The assay could be used to determine the phenobarbital plasma concentration in clinical plasma sample. Copyright © 2011 Elsevier B.V. All rights reserved.

  6. SERS-based pesticide detection by using nanofinger sensors

    NASA Astrophysics Data System (ADS)

    Kim, Ansoon; Barcelo, Steven J.; Li, Zhiyong

    2015-01-01

    Simple, sensitive, and rapid detection of trace levels of extensively used and highly toxic pesticides are in urgent demand for public health. Surface-enhanced Raman scattering (SERS)-based sensor was designed to achieve ultrasensitive and simple pesticide sensing. We developed a portable sensor system composed of high performance and reliable gold nanofinger sensor strips and a custom-built portable Raman spectrometer. Compared to the general procedure and previously reported studies that are limited to laboratory settings, our analytical method is simple, sensitive, rapid, and cost-effective. Based on the SERS results, the chemical interaction of two pesticides, chlorpyrifos (CPF) and thiabendazole (TBZ), with gold nanofingers was studied to determine a fingerprint for each pesticide. The portable SERS-sensor system was successfully demonstrated to detect CPF and TBZ pesticides within 15 min with a detection limit of 35 ppt in drinking water and 7 ppb on apple skin, respectively.

  7. Noninvasive Imaging of the Biliary System Relevant to Percutaneous Interventions

    PubMed Central

    Thomas, Stephen; Jahangir, Kayleen

    2016-01-01

    Clinical data such as history, physical examination, and laboratory tests are useful in identifying patients with biliary obstruction and biliary sources of infection. However, if intervention is planned, noninvasive imaging is needed to confirm the presence, location, and extent of the disease process. Currently, the most commonly available and used noninvasive modalities are ultrasound (US), computed tomography (CT), magnetic resonance (MR), and nuclear medicine hepatobiliary scintigraphy (HIDA). US is quick, portable, readily available, and is commonly the first imaging modality used when biliary pathology is suspected. It is excellent in the detection of cholelithiasis and acute cholecystitis but is limited in detecting choledocholithiasis. CT is excellent at detecting infected postoperative fluid collections, bilomas, biliary obstruction, and biliary infection but is limited in the detection of cholelithiasis. Therefore, US may be more useful than CT for the initial screening of acute biliary disease. MR has inherent advantages over CT, as it does not use ionizing radiation, can be done without intravenous contrast, and its detection of cholelithiasis is not affected by the internal composition of the stone. Magnetic resonance cholangiopancreatography can be used to determine the cause and location of biliary obstruction but is limited in the detection of small stones and the evaluation of the biliary tract near the ampulla. HIDA is used to evaluate for cholecystitis, biliary obstruction, and bile leaks. The main limitation is its lack of anatomical detail, and it is therefore frequently performed in conjunction with other described modalities. PMID:27904246

  8. Analysis of LANDSAT-4 TM Data for Lithologic and Image Mapping Purpose

    NASA Technical Reports Server (NTRS)

    Podwysocki, M. H.; Salisbury, J. W.; Bender, L. V.; Jones, O. D.; Mimms, D. L.

    1984-01-01

    Lithologic mapping techniques using the near infrared bands of the Thematic Mapper onboard the LANDSAT 4 satellite are investigated. These methods are coupled with digital masking to test the capability of mapping geologic materials. Data are examined under medium to low Sun angle illumination conditions to determine the detection limits of materials with absorption features. Several detection anomalies are observed and explained.

  9. Comparison of Two Assays for Molecular Determination of Rifampin Resistance in Clinical Samples from Patients with Buruli Ulcer Disease

    PubMed Central

    Phillips, Richard Odame; Badziklou, Kossi; Piten, Ebekalisai; Maman, Issaka; Sarfo, Fred Stephen; Huber, Kristina Lydia; Rhomberg, Agata; Symank, Dominik; Wagner, Magdalena; Wiedemann, Franz; Nitschke, Jörg; Banla Kere, Abiba; Herbinger, Karl-Heinz; Adjei, Ohene; Löscher, Thomas; Bretzel, Gisela

    2014-01-01

    This study evaluates a novel assay for detecting rifampin resistance in clinical Mycobacterium ulcerans isolates. Although highly susceptible for PCR inhibitors in 50% of the samples tested, the assay was 100% M. ulcerans specific and yielded >98% analyzable sequences with a lower limit of detection of 100 to 200 copies of the target sequence. PMID:24478404

  10. OZONATION BY-PRODUCTS 2. IMPROVEMENT OF AN AQUEOUS- PHASE DERIVITIZATION METHOD FOR THE DETECTION OF FORMALDEHYDE AND OTHER CARBONYL COMPOUNDS FORMED BY THE OZONATION OF DRINKING WATER

    EPA Science Inventory

    A method for the determination of low molecular weight aldehydes in water using aqueous-phase derivatization with O-(2,3,4,5,6-pentafluorobenzyl)hydroxylamine hydrochloride has been improved by the use of high-resolution capillary GC. Detection limits with GC/ECD and GC/MS with ...

  11. Multisensor fusion for the detection of mines and minelike targets

    NASA Astrophysics Data System (ADS)

    Hanshaw, Terilee

    1995-06-01

    The US Army's Communications and Electronics Command through the auspices of its Night Vision and Electronics Sensors Directorate (CECOM-NVESD) is actively applying multisensor techniques to the detection of mine targets. This multisensor research results from the 'detection activity' with its broad range of operational conditions and targets. Multisensor operation justifies significant attention by yielding high target detection and low false alarm statistics. Furthermore, recent advances in sensor and computing technologies make its practical application realistic and affordable. The mine detection field-of-endeavor has since its WWI baptismal investigated the known spectra for applicable mine observation phenomena. Countless sensors, algorithms, processors, networks, and other techniques have been investigated to determine candidacy for mine detection. CECOM-NVESD efforts have addressed a wide range of sensors spanning the spectrum from gravity field perturbations, magentic field disturbances, seismic sounding, electromagnetic fields, earth penetrating radar imagery, and infrared/visible/ultraviolet surface imaging technologies. Supplementary analysis has considered sensor candidate applicability by testing under field conditions (versus laboratory), in determination of fieldability. As these field conditions directly effect the probability of detection and false alarms, sensor employment and design must be considered. Consequently, as a given sensor's performance is influenced directly by the operational conditions, tradeoffs are necessary. At present, mass produced and fielded mine detection techniques are limited to those incorporating a single sensor/processor methodology such as, pulse induction and megnetometry, as found in hand held detectors. The most sensitive fielded systems can detect minute metal components in small mine targets but result in very high false alarm rates reducing velocity in operation environments. Furthermore, the actual speed of advance for the entire mission (convoy, movement to engagement, etc.) is determined by the level of difficulty presented in clearance or avoidance activities required in response to the potential 'targets' marked throughout a detection activity. Therefore the application of fielded hand held systems to convoy operations in clearly impractical. CECOM-NVESD efforts are presently seeking to overcome these operational limitations by substantially increasing speed of detection while reducing the false alarm rate through the application of multisensor techniques. The CECOM-NVESD application of multisensor techniques through integration/fusion methods will be defined in this paper.

  12. Comparison of ion chromatographic methods based on conductivity detection, post-column-reaction and on-line-coupling IC-ICP-MS for the determination of bromate.

    PubMed

    Schminke, G; Seubert, A

    2000-02-01

    An established method for the determination of the disinfection by-product bromate is ion chromatography (IC). This paper presents a comparison of three IC methods based on either conductivity detection (IC-CD), a post-column-reaction (IC-PCR-VIS) or the on-line-coupling with inductively coupled plasma mass spectrometry (IC-ICP-MS). Main characteristics of the methods such as method detection limits (MDL), time of analysis and sample pretreatment are compared and applicability for routine analysis is critically discussed. The most sensitive and rugged method is IC-ICP-MS, followed by IC-PCR-VIS. The photometric detection is subject to a minor interference in real world samples, presumably caused by carbonate. The lowest sensitivity is shown by the IC-CD method as slowest method compared, which, in addition, requires a sample pretreatment. The highest amount of information is delivered by IC-PCR-VIS, which allows the simultaneous determination of the seven standard anions and bromate.

  13. [Determination of 44 organophosphorus pesticides in food by SPE disk extraction-capillary gas chromatography with pulsed flame photometric detection].

    PubMed

    Luo, Xiao-Fei; Yang, Yuan; Sun, Cheng-Jun

    2012-01-01

    To develop a method for the simultaneous determination of 44 organophosphorus pesticides in food by SPE disk extraction-capillary gas chromatography with pulsed flame photometric detection. Organophosphorus pesticides in food were extracted ultrasonically with water. Then the extract was cleaned-up with SPE disk and eluted with ethyl acetate. Finally the eluent was condensed to 1mL under N2 at 55 degrees C. Gas chromatography was applied for quantitative detection of the organophosphorus pesticides in the sample. The linear range of the method for all the pesticides were in the range of 0.01-0.5 mg/kg with correlation coefficients of 0.992-1.000. The detection limits of the method were in the range of 0.0005-0.01 mg/kg. The recoveries for most pesticides were 60%-120% with relative standard deviations of less than 15%. The method is simple, sensitive, environmentally friendly and suitable for the determination of organophosphorous pesticides in food.

  14. Flow-injection analysis with electrochemical detection of reduced nicotinamide adenine dinucleotide using 2,6-dichloroindophenol as a redox coupling agent.

    PubMed

    Tang, H T; Hajizadeh, K; Halsall, H B; Heineman, W R

    1991-01-01

    The determination of reduced nicotinamide adenine dinucleotide (NADH) by electrochemical oxidation requires a more positive potential than is predicted by the formal reduction potential for the NAD+/NADH couple. This problem is alleviated by use of 2,6-dichloroindophenol (DCIP) as a redox coupling agent for NADH. The electrochemical characteristics of DCIP at the glassy carbon electrode are examined by cyclic voltammetry and hydrodynamic voltammetry. NADH is determined by reaction with DCIP to form NAD+ and DCIPH2. DCIPH2 is then quantitated by flow-injection analysis with electrochemical detection by oxidation at a detector potential of +0.25 V at pH 7. NADH is determined over a linear range of 0.5 to 200 microM and with a detection limit of 0.38 microM. The lower detection potential for DCIPH2 compared to NADH helps to minimize interference from oxidizable components in serum samples.

  15. [Sensitive and selective HPLC methods with prechromatographic derivatization for the determination of cyclamate in foods].

    PubMed

    Rüter, J; Raczek, D I

    1992-06-01

    A sensitive and selective high pressure liquid chromatography (HPLC) procedure for the determination of sodium cyclamate in juices and preserves is presented. The method depends on the oxidation of cyclamate to cyclohexylamine, which then is converted prechromatographically into a fluorescent derivative. It is analyzed by HPLC on a C18:reversed-phase column and determined with fluorescence detection (excitation at 350 nm, emission at 440-650 nm). The detection limit of sodium cyclamate was 0.5-5 mg/kg, depending on the nature and dilution of the samples. The relative standard deviations thus obtained were +/- 1.0 to +/- 2.6%. The average recovery was 90%.

  16. Determination of microcystin-LR in drinking water using UPLC tandem mass spectrometry-matrix effects and measurement.

    PubMed

    Li, Wei; Duan, Jinming; Niu, Chaoying; Qiang, Naichen; Mulcahy, Dennis

    2011-10-01

    A simple detection method using ultra-performance liquid chromatography electrospray ionisation tandem mass spectrometry (UPLC-ESI-MS-MS) coupled with the sample dilution method for determining trace microcystin-LR (MC-LR) in drinking water is presented. The limit of detection (LOD) was 0.04 µg/L and the limit of quantitation (LOQ) was 0.1 µg/L. Water matrix effects of ionic strength, dissolved organic carbon (DOC) and pH were examined. The results indicate that signal detection intensity for MC-LR was significantly suppressed as the ionic strength increased from ultrapure water condition, whereas it increased slightly with solution pH and DOC at low concentrations. However, addition of methanol (MeOH) into the sample was able to counter the signal suppression effects. In this study, dilution of the tap water sample by adding 4% MeOH (v/v) was observed to be adequate to compensate for the signal suppression. The recoveries of the samples fortified with MC-LR (0.2, 1, and 10 µg/L) for three different tap water samples ranged from 84.4% to 112.9%.

  17. Stellar Companions of Exoplanet Host Stars in K2

    NASA Astrophysics Data System (ADS)

    Matson, Rachel; Howell, Steve; Horch, Elliott; Everett, Mark

    2018-01-01

    Stellar multiplicity has significant implications for the detection and characterization of exoplanets. A stellar companion can mimic the signal of a transiting planet or distort the true planetary radii, leading to improper density estimates and over-predicting the occurrence rates of Earth-sized planets. Determining the fraction of exoplanet host stars that are also binaries allows us to better determine planetary characteristics as well as establish the relationship between binarity and planet formation. Using high-resolution speckle imaging to obtain diffraction limited images of K2 planet candidate host stars we detect stellar companions within one arcsec and up to six magnitudes fainter than the host star. By comparing our observed companion fraction to TRILEGAL star count simulations, and using the known detection limits of speckle imaging, we find the binary fraction of K2 planet host stars to be similar to that of Kepler host stars and solar-type field stars. Accounting for stellar companions in exoplanet studies is therefore essential for deriving true stellar and planetary properties as well as maximizing the returns for TESS and future exoplanet missions.

  18. Explosives signatures and analysis

    NASA Astrophysics Data System (ADS)

    Fountain, Augustus Way, III; Oyler, Jonathan M.; Ostazeski, Stanley A.

    2008-04-01

    The challenge of sampling explosive materials for various high threat military and civilian operational scenarios requires the community to identify and exploit other chemical compounds within the mixtures that may be available to support stand-off detection techniques. While limited surface and vapor phase characterization of IEDs exist, they are insufficient to guide the future development and evaluation of field deployable explosives detection (proximity and standoff) capabilities. ECBC has conducted a limited investigation of three artillery ammunition types to determine what chemical vapors, if any, are available for sensing; the relative composition of the vapors which includes the more volatile compounds in munitions, i.e., plastersizers and binders; and the sensitivity needed detect these vapors at stand-off. Also in partnership with MIT-Lincoln Laboratory, we performed a background measurement campaign at the National Training Center to determine the baseline ambient amounts and variability of nitrates and nitro-ester compounds as vapors, particulates, and on surfaces; as well as other chemical compounds related to non-energetic explosive additives. Environmental persistence studies in contexts relevant to counter-IED sensing operations, such as surface residues, are still necessary.

  19. Derivative spectrum chromatographic method for the determination of trimethoprim in honey samples using an on-line solid-phase extraction technique.

    PubMed

    Uchiyama, Kazuhisa; Kondo, Mari; Yokochi, Rika; Takeuchi, Yuri; Yamamoto, Atsushi; Inoue, Yoshinori

    2011-07-01

    A simple, selective and rapid analytical method for determination of trimethoprim (TMP) in honey samples was developed and validated. This method is based on a SPE technique followed by HPLC with photodiode array detection. After dilution and filtration, aliquots of 500 μL honey samples were directly injected to an on-line SPE HPLC system. TMP was extracted on an RP SPE column, and separated on a hydrophilic interaction chromatography column during HPLC analysis. At the first detection step, the noise level of the photodiode array data was reduced with two-dimensional equalizer filtering, and then the smoothed data were subjected to derivative spectrum chromatography. On the second-derivative chromatogram at 254 nm, the limit of detection and the limit of quantification of TMP in a honey sample were 5 and 10 ng/g, respectively. The proposed method showed high accuracy (60-103%) with adequate sensitivity for TMP monitoring in honey samples. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Multiresidue chromatographic method for the determination of macrolide residues in muscle by high-performance liquid chromatography with UV detection.

    PubMed

    Juhel-Gaugain, M; Anger, B; Laurentie, M

    1999-01-01

    A high-performance liquid chromatographic (HPLC) method for the simultaneous determination of tilmicosin, tylosin, spiramycin, and its major metabolite neospiramycin was developed that is suitable for porcine, bovine, and poultry muscles. Macrolide residues were extracted from muscle with acetonitrile, fat was removed by liquid-liquid extraction with isooctane, and the extract was then cleaned on Bond Elut C18 cartridges. The HPLC separation was performed on an Inertsil ODS3 C18 column (150 x 4 mm) with 0.05% trifluoroacetic acid-acetonitrile in a gradient mode. Two different chromatographic gradients were used for tilmicosin-tylosin and spiramycin-neospiramycin, and the detection wavelengths were 287 and 232 nm, respectively. The method was validated from 1/2 the maximum residue limit (MRL) to 4 times the MRL with pork muscle samples. Mean recoveries were 60, 63.5, 51, and 42% for tilmicosin, tylosin, spiramycin, and neospiramycin, respectively. The detection limits are 15 micrograms/kg for tilmicosin and tylosin, 30 micrograms/kg for spiramycin, and 25 micrograms/kg for neospiramycin. Linearity, precision, and accuracy of the method were also tested.

  1. Examples of variable speed limit applications : speed management workshop

    DOT National Transportation Integrated Search

    2000-01-09

    VSL systems are a type of Intelligent Transportation System (ITS) that utilizes traffic : speed and volume detection, weather information, and road surface condition technology to determine appropriate speeds at which drivers should be traveling, giv...

  2. Determination of plasma azathioprine and 6-mercaptopurine in patients with rheumatoid arthritis treated with oral azathioprine.

    PubMed

    Liliemark, J; Pettersson, B; Lafolie, P; Zweig, T; Peterson, C

    1990-07-01

    Two specific high-performance liquid chromatography methods for determining plasma concentrations of azathioprine and 6-mercaptopurine after oral administration of azathioprine are presented. It was shown that azathioprine is unstable in the blood samples unless immediately cooled in ice water. The 2-amino analog, guaneran, was used as internal standard for azathioprine, which was extracted from plasma with ethylacetate. A Nucleosil C18 column was used for the separation. The detection limit was 6 nM. For quantification of 6-mercaptopurine, 6-thioguanine was used as internal standard. Plasma was deproteinized with HClO4 and the sample was purified on mercurial cellulose. A Beckman ODS column was used and the detection limit was 5 nM. Pharmacokinetic data from two patients are presented. Unchanged azathioprine was seen until 6 h after an oral dose of 32 mg/m2.

  3. Gaussian process surrogates for failure detection: A Bayesian experimental design approach

    NASA Astrophysics Data System (ADS)

    Wang, Hongqiao; Lin, Guang; Li, Jinglai

    2016-05-01

    An important task of uncertainty quantification is to identify the probability of undesired events, in particular, system failures, caused by various sources of uncertainties. In this work we consider the construction of Gaussian process surrogates for failure detection and failure probability estimation. In particular, we consider the situation that the underlying computer models are extremely expensive, and in this setting, determining the sampling points in the state space is of essential importance. We formulate the problem as an optimal experimental design for Bayesian inferences of the limit state (i.e., the failure boundary) and propose an efficient numerical scheme to solve the resulting optimization problem. In particular, the proposed limit-state inference method is capable of determining multiple sampling points at a time, and thus it is well suited for problems where multiple computer simulations can be performed in parallel. The accuracy and performance of the proposed method is demonstrated by both academic and practical examples.

  4. Determination of trace quaternary ammonium surfactants in water by combining solid-phase extraction with surface-assisted laser desorption/ionization mass spectrometry.

    PubMed

    Chen, Y C; Sun, M C

    2001-01-01

    This study demonstrates the feasibility of combining solid-phase extraction (SPE) with surface-assisted laser desorption/ionization (SALDI) mass spectrometry to determine trace quaternary ammonium surfactants in water. The trace surfactants in water were directly concentrated on the surface of activated carbon sorbent in SPE. The activated carbon sorbent was then mixed with the SALDI liquid for SALDI analysis. No SPE elution procedure was necessary. Experimental results indicate that the surfactants with longer chain alkyl groups exhibit higher sensitivities than those with shorter chain alkyl groups in SPE-SALDI analysis. The detection limit for hexadecyltrimethylammonium bromide is around 10 ppt in SPE-SALDI analysis by sampling 100 mL of aqueous solution, while that of tetradecyltrimethylammonium bromide is about 100 ppt. The detection limit for decyltrimethylammonium bromide and dodecyltrimethylammonium bromide is in the low-ppb range. Copyright 2001 John Wiley & Sons, Ltd.

  5. Determination of enrofloxacin by room-temperature phosphorimetry after solid phase extraction on an acrylic polymer sorbent

    NASA Astrophysics Data System (ADS)

    de Souza, Cabrini F.; Martins, Renata K. S.; da Silva, Andrea R.; da Cunha, Alessandra L. M. C.; Aucélio, Ricardo Q.

    A phosphorimetric method was developed to enable the determination of enrofloxacin using photochemical derivatization which was used to both improve detection limits and to minimize the uncertainty of measurements. Phosphorescence was induced on cellulose containing TlNO3. Absolute limit of detection at the ng range and linear analytical response over three orders of magnitude were achieved. A metrological study was made to obtain the combined uncertainty value and to identify that the precision was mainly affected by the changing of substrates when measuring the signal from each replicate. Pharmaceutical formulations containing enrofloxacin were successfully analyzed by the method and the results were similar to the ones achieved using a HPLC method. A solid phase extraction on an acrylic polymer was optimized to separate enrofloxacin from interferents such as diclofenac and other components from biological matrices, which allowed the successful use of the method in urine analysis.

  6. Heterogeneity, histological features and DNA ploidy in oral carcinoma by image-based analysis.

    PubMed

    Diwakar, N; Sperandio, M; Sherriff, M; Brown, A; Odell, E W

    2005-04-01

    Oral squamous carcinomas appear heterogeneous on DNA ploidy analysis. However, this may be partly a result of sample dilution or the detection limit of techniques. The aim of this study was to determine whether oral squamous carcinomas are heterogeneous for ploidy status using image-based ploidy analysis and to determine whether ploidy status correlates with histological parameters. Multiple samples from 42 oral squamous carcinomas were analysed for DNA ploidy using an image-based system and scored for histological parameters. 22 were uniformly aneuploid, 1 uniformly tetraploid and 3 uniformly diploid. 16 appeared heterogeneous but only 8 appeared to be genuinely heterogeneous when minor ploidy histogram peaks were taken into account. Ploidy was closely related to nuclear pleomorphism but not differentiation. Sample variation, detection limits and diagnostic criteria account for much of the ploidy heterogeneity observed. Confident diagnosis of diploid status in an oral squamous cell carcinoma requires a minimum of 5 samples.

  7. [Determination of formaldehyde and acetaldehyde in packaging paper by dansylhydrazine derivatization-high performance liquid chromatography-fluorescence detection].

    PubMed

    Gong, Shuguo; Liang, Yong; Tang, Liyun; Huang, Ping; Dai, Yunhui

    2017-07-08

    A high performance liquid chromatography with fluorescence detection (HPLC-FLD) method was developed for the simultaneous determination of formaldehyde and acetaldehyde in packaging paper by dansylhydrazine (DNSH) derivatization. The samples were extracted by derivatization reagent for 30 min, and derived for 24 h. After purifying treatment with a PSA/C18 cartridge, a Diamonsil ® C18 column (150 mm×4.6 mm, 5 μ m) was used as stationary phase for separation, the mixtures of acetic acid aqueous solution (pH 2.55)-acetonitrile were used as mobile phases by gradient elution, and the excitation and emission wavelengths were 330 nm and 484 nm, respectively. The results showed that the recoveries of formaldehyde and acetaldehyde spiked in the samples were 81.64%-106.78%, and the relative standard deviations (RSDs) were 2.02%-5.53% ( n =5). The limits of detection of formaldehyde and acetaldehyde were 19.2 μ g/kg and 20.7 μ g/kg, respectively. The limits of quantification of formaldehyde and acetaldehyde were 63.9 μ g/kg and 69.1 μ g/kg, respectively. The method is simple, sensitive and reproducible. It provides a basic approach for the determination of trace formaldehyde and acetaldehyde.

  8. Dark matter effective field theory scattering in direct detection experiments

    DOE PAGES

    Schneck, K.

    2015-05-01

    We examine the consequences of the effective field theory (EFT) of dark matter–nucleon scattering for current and proposed direct detection experiments. Exclusion limits on EFT coupling constants computed using the optimum interval method are presented for SuperCDMS Soudan, CDMS II, and LUX, and the necessity of combining results from multiple experiments in order to determine dark matter parameters is discussed. We demonstrate that spectral differences between the standard dark matter model and a general EFT interaction can produce a bias when calculating exclusion limits and when developing signal models for likelihood and machine learning techniques. We also discuss the implicationsmore » of the EFT for the next-generation (G2) direct detection experiments and point out regions of complementarity in the EFT parameter space.« less

  9. Dark matter effective field theory scattering in direct detection experiments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schneck, K.; Cabrera, B.; Cerdeño, D. G.

    2015-05-18

    We examine the consequences of the effective field theory (EFT) of dark matter-nucleon scattering for current and proposed direct detection experiments. Exclusion limits on EFT coupling constants computed using the optimum interval method are presented for SuperCDMS Soudan, CDMS II, and LUX, and the necessity of combining results from multiple experiments in order to determine dark matter parameters is discussed. Here. we demonstrate that spectral differences between the standard dark matter model and a general EFT interaction can produce a bias when calculating exclusion limits and when developing signal models for likelihood and machine learning techniques. In conclusion, we discussmore » the implications of the EFT for the next-generation (G2) direct detection experiments and point out regions of complementarity in the EFT parameter space.« less

  10. Dark matter effective field theory scattering in direct detection experiments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schneck, K.; Cabrera, B.; Cerdeño, D. G.

    2015-05-18

    We examine the consequences of the effective field theory (EFT) of dark matter–nucleon scattering for current and proposed direct detection experiments. Exclusion limits on EFT coupling constants computed using the optimum interval method are presented for SuperCDMS Soudan, CDMS II, and LUX, and the necessity of combining results from multiple experiments in order to determine dark matter parameters is discussed. We demonstrate that spectral differences between the standard dark matter model and a general EFT interaction can produce a bias when calculating exclusion limits and when developing signal models for likelihood and machine learning techniques. We also discuss the implicationsmore » of the EFT for the next-generation (G2) direct detection experiments and point out regions of complementarity in the EFT parameter space.« less

  11. Ultra trace determination of 31 pesticides in water samples by direct injection-rapid resolution liquid chromatography-electrospray tandem mass spectrometry.

    PubMed

    Díaz, Laura; Llorca-Pórcel, Julio; Valor, Ignacio

    2008-08-22

    A liquid chromatography-tandem mass spectrometry (LC-MS/MS)-based method for the detection of pesticides in tap and treated wastewater was developed and validated according to the ISO/IEC 17025:1999. Key features of this method include direct injection of 100 microL of sample, an 11 min separation by means of a rapid resolution liquid chromatography system with a 4.6 mm x 50 mm, 1.8 microm particle size reverse phase column and detection by electrospray ionization (ESI) MS-MS. The limits of detection were below 15 ng L(-1) and correlation coefficients for the calibration curves in the range of 30-2000 ng L(-1) were higher than 0.99. Precision was always below 20% and accuracy was confirmed by external evaluation. The main advantages of this method are direct injection of sample without preparative procedures and low limits of detection that fulfill the requirements established by the current European regulations governing pesticide detection.

  12. Apparatus and method for quantitatively evaluating total fissile and total fertile nuclide content in samples

    DOEpatents

    Caldwell, John T.; Kunz, Walter E.; Cates, Michael R.; Franks, Larry A.

    1985-01-01

    Simultaneous photon and neutron interrogation of samples for the quantitative determination of total fissile nuclide and total fertile nuclide material present is made possible by the use of an electron accelerator. Prompt and delayed neutrons produced from resulting induced fissions are counted using a single detection system and allow the resolution of the contributions from each interrogating flux leading in turn to the quantitative determination sought. Detection limits for .sup.239 Pu are estimated to be about 3 mg using prompt fission neutrons and about 6 mg using delayed neutrons.

  13. Apparatus and method for quantitatively evaluating total fissile and total fertile nuclide content in samples. [Patent application

    DOEpatents

    Caldwell, J.T.; Kunz, W.E.; Cates, M.R.; Franks, L.A.

    1982-07-07

    Simultaneous photon and neutron interrogation of samples for the quantitative determination of total fissile nuclide and total fertile nuclide material present is made possible by the use of an electron accelerator. Prompt and delayed neutrons produced from resulting induced fission are counted using a single detection system and allow the resolution of the contributions from each interrogating flux leading in turn to the quantitative determination sought. Detection limits for /sup 239/Pu are estimated to be about 3 mg using prompt fission neutrons and about 6 mg using delayed neutrons.

  14. Authenticity analysis of pear juice employing chromatographic fingerprinting.

    PubMed

    Willems, Jamie L; Low, Nicholas H

    2014-12-03

    Pear juice is predominately composed of carbohydrates/polyols (>95% of the total soluble solids), making it susceptible to adulteration by the addition of less expensive commercial sweeteners. In this research, the major carbohydrate and polyol (fructose, glucose, sucrose, and sorbitol) content of 32 pure pear juices representing five world producing regions and three years of production was determined. Additionally, methods employing oligosaccharide profiling to detect the debasing of these samples with four commercial sweeteners (HFCS 55 and 90, TIS, and HIS) were developed using capillary gas chromatography with flame ionization detection (CGC-FID) and high-performance liquid chromatography with pulsed amperometric detection (HPAE-PAD). Detection limits for the four commercial sweeteners ranged from 0.5 to 5.0% (v/v). In addition, the developed CGC-FID method could be used to (a) detect the addition of pear to apple juice via arbutin detection and (b) determine if a pear juice was produced using enzymatic liquefaction via the presence of O-β-d-glucopyranosyl-(1→4)-d-glucopyranose (cellobiose), all within a single chromatographic analysis.

  15. Fundamental limits of measurement in telecommunications: Experimental and modeling studies in a test optical network on proposal for the reform of telecommunication quantitations

    NASA Astrophysics Data System (ADS)

    Egan, James; McMillan, Normal; Denieffe, David

    2011-08-01

    Proposals for a review of the limits of measurement for telecommunications are made. The measures are based on adapting work from the area of chemical metrology for the field of telecommunications. Currie has introduced recommendations for defining the limits of measurement in chemical metrology and has identified three key fundamental limits of measurement. These are the critical level, the detection limit and the determination limit. Measurements on an optical system are used to illustrate the utility of these measures and discussion is given into the advantages of using these fundamental quantitations over existing methods.

  16. Simultaneous determination of diclofenac and oxybuprocaine in human aqueous humor with HPLC and electrochemical detection.

    PubMed

    Kuhlmann, O; Stoldt, G; Struck, H G; Krauss, G J

    1998-09-01

    A sensitive and selective bioanalytical method for simultaneous determination of diclofenac and oxybuprocaine in human aqueous humor using reversed-phase HPLC and electrochemical detection is described. Chromatographic separation was achieved by using a Regis SPS 100 RP-8 column (5 microns; 150 x 4.6 mm I.D.). This support is coated with a hydrophilic polyoxyethylenepolymer. It allows protein-containing samples to be injected directly onto the column. The electrochemical detector permit a detection limit of 500 pg diclofenac per ml (daily relative standard deviation 6.3%) and 50 ng oxybuprocaine per ml (daily R.S.D. 2.6%), respectively. Results of administered and measured drug-concentrations in time dependent decrease are presented.

  17. [Determination of cyclamate in complex matrix using HPLC after column derivatization with 4-fluoro-7-nitrobenzofurazan].

    PubMed

    Hauck, M; Köbler, H

    1990-01-01

    A method for the analysis of cyclamate in complex foodstuffs has been developed. This method is applicable in strongly coloured and protein-rich foodstuffs. The quantitative determination depends on oxidation of cyclamate to cyclohexylamine and derivatisation with 4-fluoro-7-nitrobenzofuran (NBD-F). The derivatives are analysed by HPLC on a C18: reversed-phase column, their minimal stability being 12 h. There are two possible methods of detection: (a) absorbance at 485 nm and (b) fluorescence with excitation at 485 nm and emission at 530 nm. The detection limit of cyclamate is 5 mg/kg foodstuff, with fluorescence detection 0.4 mg/kg. The recoveries are in the range of 88% to 104%.

  18. Directly detecting isospin-violating dark matter

    NASA Astrophysics Data System (ADS)

    Kelso, Chris; Kumar, Jason; Marfatia, Danny; Sandick, Pearl

    2018-03-01

    We consider the prospects for multiple dark matter direct detection experiments to determine if the interactions of a dark matter candidate are isospin-violating. We focus on theoretically well-motivated examples of isospin-violating dark matter (IVDM), including models in which dark matter interactions with nuclei are mediated by a dark photon, a Z , or a squark. We determine that the best prospects for distinguishing IVDM from the isospin-invariant scenario arise in the cases of dark photon-or Z -mediated interactions, and that the ideal experimental scenario would consist of large exposure xenon- and neon-based detectors. If such models just evade current direct detection limits, then one could distinguish such models from the standard isospin-invariant case with two detectors with of order 100 ton-year exposure.

  19. Search for geo-neutrinos and rare nuclear processes with Borexino

    NASA Astrophysics Data System (ADS)

    Caminata, Alessio; Davini, Stefano; di Noto, Lea; Pallavicini, Marco; Testera, Gemma; Zavatarelli, Sandra

    2018-03-01

    Borexino was designed to measure solar neutrinos in the MeV or sub-MeV energy range. The unprecedented radiopurity of the detector has allowed the detection of geo-neutrinos and the determination of competitive limits on the rate of rare or forbidden processes. In this paper, we review the basic principle of neutrinos and antineutrinos detection in Borexino and we describe the results of the geo-neutrinos measurements and their implications. Then we summarize the search for Borexino events correlated with gamma ray bursts and for axion induced signals, and the limits achieved on Pauli forbidden transitions and on the electron charge conservation.

  20. Concentrations of platinum group elements in 122 U.S. coal samples

    USGS Publications Warehouse

    Oman, C.L.; Finkelman, R.B.; Tewalt, S.J.

    1997-01-01

    Analysis of more than 13,000 coal samples by semi-quantitative optical emission spectroscopy (OES) indicates that concentrations of the platinum group elements (iridium, palladium, platinum, osmium, rhodium, and ruthenium) are less than 1 ppm in the ash, the limit of detection for this method of analysis. In order to accurately determine the concentration of the platinum group elements (PGE) in coal, additional data were obtained by inductively coupled plasma mass spectroscopy, an analytical method having part-per-billion (ppb) detection limits for these elements. These data indicate that the PGE in coal occur in concentrations on the order of 1 ppb or less.

  1. Molecular Detection of Antimicrobial Resistance

    PubMed Central

    Fluit, Ad C.; Visser, Maarten R.; Schmitz, Franz-Josef

    2001-01-01

    The determination of antimicrobial susceptibility of a clinical isolate, especially with increasing resistance, is often crucial for the optimal antimicrobial therapy of infected patients. Nucleic acid-based assays for the detection of resistance may offer advantages over phenotypic assays. Examples are the detection of the methicillin resistance-encoding mecA gene in staphylococci, rifampin resistance in Mycobacterium tuberculosis, and the spread of resistance determinants across the globe. However, molecular assays for the detection of resistance have a number of limitations. New resistance mechanisms may be missed, and in some cases the number of different genes makes generating an assay too costly to compete with phenotypic assays. In addition, proper quality control for molecular assays poses a problem for many laboratories, and this results in questionable results at best. The development of new molecular techniques, e.g., PCR using molecular beacons and DNA chips, expands the possibilities for monitoring resistance. Although molecular techniques for the detection of antimicrobial resistance clearly are winning a place in routine diagnostics, phenotypic assays are still the method of choice for most resistance determinations. In this review, we describe the applications of molecular techniques for the detection of antimicrobial resistance and the current state of the art. PMID:11585788

  2. A simple and inexpensive point-of-care test for hepatitis B surface antigen detection: serological and molecular evaluation.

    PubMed

    Gish, R G; Gutierrez, J A; Navarro-Cazarez, N; Giang, K; Adler, D; Tran, B; Locarnini, S; Hammond, R; Bowden, S

    2014-12-01

    Early identification of chronic hepatitis B is important for optimal disease management and prevention of transmission. Cost and lack of access to commercial hepatitis B surface antigen (HBsAg) immunoassays can compromise the effectiveness of HBV screening in resource-limited settings and among marginalized populations. High-quality point-of-care (POC) testing may improve HBV diagnosis in these situations. Currently available POC HBsAg assays are often limited in sensitivity. We evaluated the NanoSign(®) HBs POC chromatographic immunoassay for its ability to detect HBsAg of different genotypes and with substitutions in the 'a' determinant. Thirty-seven serum samples from patients with HBV infection, covering HBV genotypes A-G, were assessed for HBsAg titre with the Roche Elecsys HBsAg II quantification assay and with the POC assay. The POC assay reliably detected HBsAg at a concentration of at least 50 IU/mL for all genotypes, and at lower concentrations for some genotypes. Eight samples with substitutions in the HBV 'a' determinant were reliably detected after a 1/100 dilution. The POC strips were used to screen serum samples from 297 individuals at risk for HBV in local clinical settings (health fairs and outreach events) in parallel with commercial laboratory HBsAg testing (Quest Diagnostics EIA). POC testing was 73.7% sensitive and 97.8% specific for detection of HBsAg. Although the POC test demonstrated high sensitivity over a range of genotypes, false negatives were frequent in a clinical setting. Nevertheless, the POC assay offers advantages for testing in both developed and resource-limited countries due to its low cost (0.50$) and immediately available results. © 2014 John Wiley & Sons Ltd.

  3. Tracking Dissolved Methane Concentrations near Active Seeps and Gas Hydrates: Sea of Japan.

    NASA Astrophysics Data System (ADS)

    Snyder, G. T.; Aoki, S.; Matsumoto, R.; Tomaru, H.; Owari, S.; Nakajima, R.; Doolittle, D. F.; Brant, B.

    2015-12-01

    A number of regions in the Sea of Japan are known for active gas venting and for gas hydrate exposures on the sea floor. In this investigation we employed several gas sensors mounted on a ROV in order to determine the concentrations of dissolved methane in the water near these sites. Methane concentrations were determined during two-second intervals throughout each ROV deployment during the cruise. The methane sensor deployments were coupled with seawater sampling using Niskin bottles. Dissolved gas concentrations were later measured using gas chromatography in order to compare with the sensor results taken at the same time. The observed maximum dissolved methane concentrations were much lower than saturation values, even when the ROV manipulators were in contact with gas hydrate. Nonetheless, dissolved concentrations did reach several thousands of nmol/L near gas hydrate exposures and gas bubbles, more than two orders of magnitude over the instrumental detection limits. Most of the sensors tested were able to detect dissolved methane concentrations as low as 10 nmol/L which permitted detection when the ROV approached methane plume sites, even from several tens of meters above the sea floor. Despite the low detection limits, the methane sensors showed variable response times when returning to low-background seawater (~5nM). For some of the sensors, the response time necessary to return to background values occurred in a matter of minutes, while for others it took several hours. Response time, as well as detection limit, should be an important consideration when selecting methane sensors for ROV or AUV investigations. This research was made possible, in part, through funding provided by the Japanese Ministry of Economy, Trade and Industry (METI).

  4. Analytical methods for the determination of urinary 2,4-dichlorophenoxyacetic acid and 2-methyl-4-chlorophenoxyacetic acid in occupationally exposed subjects and in the general population.

    PubMed

    Aprea, C; Sciarra, G; Bozzi, N

    1997-01-01

    Two methods for the quantitative analysis of 2,4-dichlorophenoxyacetic acid (2,4-D) and 2-methyl-4-chlorophenoxyacetic acid (MCPA) in urine were compared. The first was an high-performance liquid chromatography method using a C8 column with ion suppression and diode array detection. The urine extracts were first purified by solid-phase extraction (SPE) on silica capillary columns. The detection limit of the method was 15 micrograms/L for both compounds. The percentage coefficient of variation of the whole analysis evaluated at a concentration of 125.0 micrograms/L was 6.2% for 2,4-D and 6.8% for MCPA. The mean recovery of analysis was 81% for 2,4-D and 85% for MCPA. The second was a gas chromatographic (GC) method in which the compounds were first derivatized with pentafluorobenzylbromide to pentafluorobenzyl esters, which were determined with a slightly polar capillary column and electron capture detection. Before GC analysis, the urine extracts were purified by SPE on silica capillary columns. This method had a detection limit of 1 microgram/L for both compounds and a percentage coefficient of variation of the whole analysis, evaluated at a concentration of 30.0 micrograms/L, of 8% for 2,4-D, and of 5.5% for MCPA. the mean recovery was 87% for 2,4-D and 94% for MCPA. The low detection limit made the second method suitable for assaying the two herbicides in the general population. Duplicate analysis of ten urine samples from occupationally exposed subjects by the two methods gave identical results for a wide range of concentrations.

  5. Determination of artificial sweeteners by capillary electrophoresis with contactless conductivity detection optimized by hydrodynamic pumping.

    PubMed

    Stojkovic, Marko; Mai, Thanh Duc; Hauser, Peter C

    2013-07-17

    The common sweeteners aspartame, cyclamate, saccharin and acesulfame K were determined by capillary electrophoresis with contactless conductivity detection. In order to obtain the best compromise between separation efficiency and analysis time hydrodynamic pumping was imposed during the electrophoresis run employing a sequential injection manifold based on a syringe pump. Band broadening was avoided by using capillaries of a narrow 10 μm internal diameter. The analyses were carried out in an aqueous running buffer consisting of 150 mM 2-(cyclohexylamino)ethanesulfonic acid and 400 mM tris(hydroxymethyl)aminomethane at pH 9.1 in order to render all analytes in the fully deprotonated anionic form. The use of surface modification to eliminate or reverse the electroosmotic flow was not necessary due to the superimposed bulk flow. The use of hydrodynamic pumping allowed easy optimization, either for fast separations (80s) or low detection limits (6.5 μmol L(-1), 5.0 μmol L(-1), 4.0 μmol L(-1) and 3.8 μmol L(-1) for aspartame, cyclamate, saccharin and acesulfame K respectively, at a separation time of 190 s). The conditions for fast separations not only led to higher limits of detection but also to a narrower dynamic range. However, the settings can be changed readily between separations if needed. The four compounds were determined successfully in food samples. Copyright © 2013 Elsevier B.V. All rights reserved.

  6. [Determination of vitamins D2, vitamin D3 in cosmetics by high performance liquid chromatography].

    PubMed

    Zhu, Ying; Yang, Yan-Wei; Wang, Xin

    2005-09-01

    A high performance liquid chromatography method was used to detect vitamins D2 and vitamin D3, which is useful to know the use of vitamins D2 and vitamin D3 in cosmetics, prohibit the influx of cosmetics containing vitamins D2 and vitamin D3 to cosmetic market, safeguard the health of consumers. A high performance liquid chromatography method was established for determination of vitamins D2 and vitamin D3 in cosmetics. The separation condition was optimized by trying different type of columns and mobile phases. The experiment goes on a Alltima C18 column (250 mm x 4.6 mm I. D., 5 microm)using methanol-acetonitrile (90: 10) as mobile phase at a flow rate of 1.0 ml/min, with the column temperature 25 degrees C and detection wave 265nm. The liner range is from 0.5 mg/L to 100 mg/L with good relationship. The detection limit of vitamin D2 is 0. 12 mg/L, the precision is less than 3.8% and recovery varies from 94.2% to 101.4%, while the detection limit of vitamin D3 is 0.06 mg/L, the precision is less than 3.5% and recovery varies from 91.6% to 97.2%. The method is simple, precise and accurate, which is suitable for the determination of vitamins D2 and vitamin D3 in cosmetics.

  7. Detection of trace fluoride in serum and urine by online membrane-based distillation coupled with ion chromatography.

    PubMed

    Lou, Chaoyan; Guo, Dandan; Wang, Nani; Wu, Shuchao; Zhang, Peimin; Zhu, Yan

    2017-06-02

    An online membrane-based distillation (MBD) coupled with ion chromatography (IC) method was proposed for automatic detection of trace fluoride (F - ) in serum and urine samples. The system consisted of a sample vessel, a lab-made membrane module and an ion chromatograph. Hydrophobic polytetrafluoroethylene (PTFE) hollow fiber membrane was used in MBD which was directly performed in serum and urine samples to eliminate the matrix interferences and enrich fluoride, while enabling automation. The determination of fluoride in biological samples was carried out by IC with suppressed conductometric detection. The proposed method feasibly determined trace fluoride in serum and urine matrices with the optimized parameters, such as acid concentration, distillation temperature, and distillation time, etc. Fluoride exhibited satisfactory linearity in the range of 0.01-5.0mg/L with a correlation coefficient of 0.9992. The limit of detection (LOD, S/N=3) and limit of quantification (LOQ, S/N=10) were 0.78μg/L and 2.61μg/L, respectively. The relative standard deviations of peak area and peak height were all less than 5.15%. The developed method was validated for the determination of fluoride in serum and urine with good spiked recoveries ranging between 97.1-101.9%. This method also can be proposed as a suitable alternative for the analysis of fluoride in other complex biological samples. Copyright © 2017. Published by Elsevier B.V.

  8. Determination of secondary and tertiary amines as N-nitrosamine precursors in drinking water system using ultra-fast liquid chromatography-tandem mass spectrometry.

    PubMed

    Wu, Qihua; Shi, Honglan; Ma, Yinfa; Adams, Craig; Eichholz, Todd; Timmons, Terry; Jiang, Hua

    2015-01-01

    N-Nitrosamines are potent mutagenic and carcinogenic emerging water disinfection by-products (DBPs). The most effective strategy to control the formation of these DBPs is minimizing their precursors from source water. Secondary and tertiary amines are dominating precursors of N-nitrosamines formation during drinking water disinfection process. Therefore, the screening and removal of these amines in source water are very essential for preventing the formation of N-nitrosamines. A rapid, simple, and sensitive ultrafast liquid chromatography-tandem mass spectrometry (UFLC-MS/MS) method has been developed in this study to determine seven amines, including dimethylamine, ethylmethylamine, diethylamine, dipropylamine, trimethylamine, 3-(dimethylaminomethyl)indole, and 4-dimethylaminoantipyrine, as major precursors of N-nitrosamines in drinking water system. No sample preparation process is needed except a simple filtration. Separation and detection can be achieved in 11 min per sample. The method detection limits of selected amines are ranging from 0.02 μg/L to 1 μg/L except EMA (5 μg/L), and good calibration linearity was achieved. The developed method was applied to determine the selected precursors in source water and drinking water samples collected from Midwest area of the United States. In most of water samples, the concentrations of selected precursors of N-nitrosamines were below their method detection limits. Dimethylamine was detected in some of water samples at the concentration up to 25.4 μg/L. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. Background correction in forensic photography. II. Photography of blood under conditions of non-uniform illumination or variable substrate color--practical aspects and limitations.

    PubMed

    Wagner, John H; Miskelly, Gordon M

    2003-05-01

    The combination of photographs taken at wavelengths at and bracketing the peak of a narrow absorbance band can lead to enhanced visualization of the substance causing the narrow absorbance band. This concept can be used to detect putative bloodstains by division of a linear photographic image taken at or near 415 nm with an image obtained by averaging linear photographs taken at or near 395 and 435 nm. Nonlinear images can also be background corrected by substituting subtraction for the division. This paper details experimental applications and limitations of this technique, including wavelength selection of the illuminant and at the camera. Characterization of a digital camera to be used in such a study is also detailed. Detection limits for blood using the three wavelength correction method under optimum conditions have been determined to be as low as 1 in 900 dilution, although on strongly patterned substrates blood diluted more than twenty-fold is difficult to detect. Use of only the 435 nm photograph to estimate the background in the 415 nm image lead to a twofold improvement in detection limit on unpatterned substrates compared with the three wavelength method with the particular camera and lighting system used, but it gave poorer background correction on patterned substrates.

  10. Use of x-ray fluorescence for in-situ detection of metals

    NASA Astrophysics Data System (ADS)

    Elam, W. T. E.; Whitlock, Robert R.; Gilfrich, John V.

    1995-01-01

    X-ray fluorescence (XRF) is a well-established, non-destructive method of determining elemental concentrations at ppm levels in complex samples. It can operate in atmosphere with no sample preparation, and provides accuracies of 1% or better under optimum conditions. This report addresses two sets of issues concerning the use of x-ray fluorescence as a sensor technology for the cone penetrometer, for shipboard waste disposal, or for other in-situ, real- time environmental applications. The first issue concerns the applicability of XRF to these applications, and includes investigation of detection limits and matrix effects. We have evaluated the detection limits and quantitative accuracy of a sensor mock-up for metals in soils under conditions expected in the field. In addition, several novel ways of improving the lower limits of detection to reach the drinking water regulatory limits have been explored. The second issue is the engineering involved with constructing a spectrometer within the 1.75 inch diameter of the penetrometer pipe, which is the most rigorous physical constraint. Only small improvements over current state-of-the-art are required. Additional advantages of XRF are that no radioactive sources or hazardous materials are used in the sensor design, and no reagents or any possible sources of ignition are involved.

  11. Effects of Kapton Sample Cell Windows on the Detection Limit of Smectite: Implications for CheMin on the Mars Science Laboratory Mission

    NASA Technical Reports Server (NTRS)

    Achilles, C. N.; Ming, Douglas W.; Morris, R. V.; Blake, D. F.

    2012-01-01

    The CheMin instrument on the Mars Science Laboratory (MSL) rover Curiosity is an X-ray diffraction (XRD) and X-ray fluorescence (XRF) instrument capable of providing the mineralogical and chemical compositions of rocks and soils on the surface of Mars. CheMin uses a microfocus X-ray tube with a Co target, transmission geometry, and an energy-discriminating X-ray sensitive CCD to produce simultaneous 2-D XRD patterns and energy-dispersive X-ray histograms from powdered samples. CheMin has two different window materials used for sample cells -- Mylar and Kapton. Instrument details are provided elsewhere. Fe/Mg-smectite (e.g., nontronite) has been identified in Gale Crater, the MSL future landing site, by CRISM spectra. While large quantities of phyllosilicate minerals will be easily detected by CheMin, it is important to establish detection limits of such phases to understand capabilities and limitations of the instrument. A previous study indicated that the (001) peak of smectite at 15 Ang was detectable in a mixture of 1 wt.% smectite with olivine when Mylar is the window material for the sample cell. Complications arise when Kapton is the window material because Kapton itself also has a diffraction peak near 15 Ang (6.8 deg 2 Theta). This study presents results of mineral mixtures of smectite and olivine to determine smectite detection limits for Kapton sample cells. Because the intensity and position of the smectite (001) peak depends on the hydration state, we also analyzed mixtures with "hydrated" and "dehydrated"h smectite to examine the effects of hydration state on detection limits.

  12. Analysis of volatile organic compounds from illicit cocaine samples

    NASA Astrophysics Data System (ADS)

    Robins, W. H.; Wright, Bob W.

    1994-10-01

    Detection of illicit cocaine hydrochloride shipments can be improved if there is a greater understanding of the identity and quantity of volatile compounds present. This study provides preliminary data concerning the volatile organic compounds detected in a limited set of cocaine hydrochloride samples. In all cases, cocaine was one of the major volatile compounds detected. Other tropeines were detected in almost all samples. Low concentrations of compounds which may be residues of processing solvents were observed in some samples. The equilibrium emissivity of cocaine from cocaine hydrochloride was investigated and a value of 83 parts-per-trillion was determined.

  13. Reliability of scanning laser acoustic microscopy for detecting internal voids in structural ceramics

    NASA Technical Reports Server (NTRS)

    Roth, D. J.; Baaklini, G. Y.

    1986-01-01

    The reliability of 100 MHz scanning laser acoustic microscopy (SLAM) for detecting internal voids in sintered specimens of silicon nitride and silicon carbide was evaluated. The specimens contained artificially implanted voids and were positioned at depths ranging up to 2 mm below the specimen surface. Detection probability of 0.90 at a 0.95 confidence level was determined as a function of material, void diameter, and void depth. The statistical results presented for void detectability indicate some of the strengths and limitations of SLAM as a nondestructive evaluation technique for structural ceramics.

  14. Development of an automated on-line electrochemical chlorite ion sensor.

    PubMed

    Myers, John N; Steinecker, William H; Sandlin, Zechariah D; Cox, James A; Gordon, Gilbert; Pacey, Gilbert E

    2012-05-30

    A sensor system for the automatic, in-line, determination of chlorite ion is reported. Electroanalytical measurements were performed in electrolyte-free liquids by using an electrochemical probe (EC), which enables in-line detection in high-resistance media such as disinfected water. Cyclic voltammetry scan rate studies suggest that the current arising from the oxidation of chlorite ion at an EC probe is mass-transfer limited. By coupling FIA with an EC probe amperometric cell, automated analysis was achieved. This sensor is intended to fulfill the daily monitoring requirements of the EPA DBP regulations for chlorite ion. Detection limits of 0.02-0.13 mg/L were attained, which is about one order of magnitude below the MRDL. The sensor showed no faradaic signal for perchlorate, chlorate, or nitrate. The lifetime and stability of the sensor were investigated by measuring calibration curves over time under constant-flow conditions. Detection limits of <0.1 mg/L were repeatedly achieved over a period of three weeks. Copyright © 2012 Elsevier B.V. All rights reserved.

  15. “Development of an Automated On-line Electrochemical Chlorite Ion Sensor”

    PubMed Central

    Myers, John N.; Steinecker, William H.; Sandlin, Zechariah D.; Cox, James A.; Gordon, Gilbert; Pacey, Gilbert E.

    2012-01-01

    A sensor system for the automatic, in-line, determination of chlorite ion is reported. Electroanalytical measurements were performed in electrolyte-free liquids by using an electrochemical probe (EC), which enables in-line detection in high-resistance media such as disinfected water. Cyclic voltammetry scan rate studies suggest that the current arising from the oxidation of chlorite ion at an EC probe is mass-transfer limited. By coupling FIA with an EC probe amperometric cell, automated analysis was achieved. This sensor is intended to fulfill the daily monitoring requirements of the EPA DBP regulations for chlorite ion. Detection limits of 0.02-0.13 mg/L were attained, which is about one order of magnitude below the MRDL. The sensor showed no faradaic signal for perchlorate, chlorate, or nitrate. The lifetime and stability of the sensor were investigated by measuring calibration curves over time under constant-flow conditions. Detection limits of <0.1 mg/L were repeatedly achieved over a period of three weeks. PMID:22608440

  16. Considerations on the determination of the limit of detection and the limit of quantification in one-dimensional and comprehensive two-dimensional gas chromatography.

    PubMed

    Krupčík, Ján; Májek, Pavel; Gorovenko, Roman; Blaško, Jaroslav; Kubinec, Robert; Sandra, Pat

    2015-05-29

    Methods based on the blank signal as proposed by IUPAC procedure and on the signal to noise ratio (S/N) as listed in the ISO-11843-1 norm for determination of the limit of detection (LOD) and quantitation (LOQ) in one-dimensional capillary gas chromatography (1D-GC) and comprehensive two-dimensional capillary gas chromatography (CG×GC) are described in detail and compared for both techniques. Flame ionization detection was applied and variables were the data acquisition frequency and, for CG×GC, also the modulation time. It has been stated that LOD and LOQ estimated according to IUPAC might be successfully used for 1D-GC-FID method. Moreover, LOD and LOQ decrease with decrease of data acquisition frequency (DAF). For GC×GC-FID, estimation of LOD by IUPAC gave poor reproducibility of results while for LOQ reproducibility was acceptable (within ±10% rel.). The LOD and LOQ determined by the S/N concept both for 1D-GC-FID and GC×GC-FID methods are ca. three times higher than those values estimated by the standard deviation of the blank. Since the distribution pattern of modulated peaks for any analyte separated by GC×GC is random and cannot be predicted, LOQ and LOD may vary within 30% for 3s modulation time. Concerning sensitivity, 1D-GC-FID at 2Hz and of GC×GC-FID at 50Hz shows a ca. 5 times enhancement of sensitivity in the modulated signal output. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Contrast limited adaptive histogram equalization image processing to improve the detection of simulated spiculations in dense mammograms.

    PubMed

    Pisano, E D; Zong, S; Hemminger, B M; DeLuca, M; Johnston, R E; Muller, K; Braeuning, M P; Pizer, S M

    1998-11-01

    The purpose of this project was to determine whether Contrast Limited Adaptive Histogram Equalization (CLAHE) improves detection of simulated spiculations in dense mammograms. Lines simulating the appearance of spiculations, a common marker of malignancy when visualized with masses, were embedded in dense mammograms digitized at 50 micron pixels, 12 bits deep. Film images with no CLAHE applied were compared to film images with nine different combinations of clip levels and region sizes applied. A simulated spiculation was embedded in a background of dense breast tissue, with the orientation of the spiculation varied. The key variables involved in each trial included the orientation of the spiculation, contrast level of the spiculation and the CLAHE settings applied to the image. Combining the 10 CLAHE conditions, 4 contrast levels and 4 orientations gave 160 combinations. The trials were constructed by pairing 160 combinations of key variables with 40 backgrounds. Twenty student observers were asked to detect the orientation of the spiculation in the image. There was a statistically significant improvement in detection performance for spiculations with CLAHE over unenhanced images when the region size was set at 32 with a clip level of 2, and when the region size was set at 32 with a clip level of 4. The selected CLAHE settings should be tested in the clinic with digital mammograms to determine whether detection of spiculations associated with masses detected at mammography can be improved.

  18. Solid-phase microextraction of benzimidazole fungicides in environmental liquid samples and HPLC-fluorescence determination.

    PubMed

    López Monzón, A; Vega Moreno, D; Torres Padrón, M E; Sosa Ferrera, Z; Santana Rodríguez, J J

    2007-03-01

    Solid-phase microextraction (SPME) coupled with high-performance liquid chromatography (HPLC) with fluorescence detection was optimized for extraction and determination of four benzimidazole fungicides (benomyl, carbendazim, thiabendazole, and fuberidazole) in water. We studied extraction and desorption conditions, for example fiber type, extraction time, ionic strength, extraction temperature, and desorption time to achieve the maximum efficiency in the extraction. Results indicate that SPME using a Carboxen-polydimethylsiloxane 75 microm (CAR-PDMS) fiber is suitable for extraction of these types of compound. Final analysis of benzimidazole fungicides was performed by HPLC with fluorescence detection. Recoveries ranged from 80.6 to 119.6 with RSDs below 9% and limits of detection between 0.03 and 1.30 ng mL-1 for the different analytes. The optimized procedure was applied successfully to the determination of benzimidazole fungicides mixtures in environmental water samples (sea, sewage, and ground water).

  19. Tremella-like graphene-Au composites used for amperometric determination of dopamine.

    PubMed

    Li, Cong; Zhao, Jingyu; Yan, Xiaoyi; Gu, Yue; Liu, Weilu; Tang, Liu; Zheng, Bo; Li, Yaru; Chen, Ruixue; Zhang, Zhiquan

    2015-03-21

    Electrochemical detection of dopamine (DA) plays an important role in medical diagnosis. In this paper, tremella-like graphene-Au (t-GN-Au) composites were synthesized by a one-step hydrothermal method for selective detection of DA. Scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS), X-ray diffraction (XRD), Raman spectroscopy, and Fourier transform infrared (FTIR) spectroscopy were used to characterize as-prepared t-GN-Au composites. The t-GN-Au composites were directly used for the determination of DA via cyclic voltammetry (CV) and the chronoamperometry (CA) technique. CA measurement gave a wide linear range from 0.8 to 2000 μM, and the detection limit of 57 nM (S/N = 3) for DA. The mechanism and the heterogeneous electron transfer kinetics of the DA oxidation were discussed in the light of rotating disk electrode (RDE) experiments. Moreover, the modified electrode was applied to the determination of DA in human urine and serum samples.

  20. Determination of myriocin in natural and cultured Cordyceps cicadae using 9-fluorenylmethyl chloroformate derivatization and high-performance liquid chromatography with UV-detection.

    PubMed

    Yu, Jiawen; Xu, Hongjuan; Mo, Zhihong; Zhu, Huali; Mao, Xianbing

    2009-07-01

    A simple and sensitive reversed-phase liquid chromatographic method, based on the precolumn derivatization with 9-fluorenylmethyl chloroformate, was developed for the determination of myriocin. The derivatization reaction was performed in organic solvents of pyridine and tetrahydrofuran at 40 degrees C. Several factors influencing the derivative yield were investigated and optimized. The formed derivative was stable for more than 24 h at room temperature. The detection wavelength was 262 nm. The system offered the following analytical parameters: the limit of detection was 0.045 microg ml(-1), the linear correlation coefficient was 0.9963 and the linear range response was from 2.0 to 500.0 microg ml(-1). The precision of the method was <2.0%. As a preliminary application, the method has been successfully applied to the determination of myriocin in natural and cultured Cordyceps cicadae.

  1. Determination of Macrolide Antibiotics Using Dispersive Liquid-Liquid Microextraction Followed by Surface-Assisted Laser Desorption/Ionization Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Chen, Kuan-Yu; Yang, Thomas C.; Chang, Sarah Y.

    2012-06-01

    A novel method for the determination of macrolide antibiotics using dispersive liquid-liquid microextraction coupled to surface-assisted laser desorption/ionization mass spectrometric detection was developed. Acetone and dichloromethane were used as the disperser solvent and extraction solvent, respectively. A mixture of extraction solvent and disperser solvent were rapidly injected into a 1.0 mL aqueous sample to form a cloudy solution. After the extraction, macrolide antibiotics were detected using surface-assisted laser desorption/ionization mass spectrometry (SALDI/MS) with colloidal silver as the matrix. Under optimum conditions, the limits of detection (LODs) at a signal-to-noise ratio of 3 were 2, 3, 3, and 2 nM for erythromycin (ERY), spiramycin (SPI), tilmicosin (TILM), and tylosin (TYL), respectively. This developed method was successfully applied to the determination of macrolide antibiotics in human urine samples.

  2. Electroanalytical method for determination of lead(II) in orange and apple using kaolin modified platinum electrode.

    PubMed

    El Mhammedi, M A; Achak, M; Bakasse, M; Chtaini, A

    2009-08-01

    This paper reports on the use of platinum electrode modified with kaolin (K/Pt) and square wave voltammetry for analytical detection of trace lead(II) in pure water, orange and apple samples. The electroanalytical procedure for determination of the Pb(II) comprises two steps: the chemical accumulation of the analyte under open-circuit conditions followed by the electrochemical detection of the preconcentrated species using square wave voltammetry. The analytical performances of the extraction method has been explored by studying the incubating time, and effect of interferences due to other ions. During the preconcentration step, Pb(II) was accumulated on the surface of the kaolin. The observed detection and quantification limits in pure water were 3.6x10(-9)molL(-1) and 1.2x10(-8)molL(-1), respectively. The precision of the method was also determined; the results was 2.35% (n=5).

  3. Simultaneous determination of 12 chemical constituents in the traditional Chinese Medicinal Prescription Xiao-Yao-San-Jia-Wei by HPLC coupled with photodiode array detection.

    PubMed

    Zhang, Hongmin; Chen, Shiwei; Qin, Feng; Huang, Xi; Ren, Ping; Gu, Xinqi

    2008-12-15

    An HPLC-photodiode array (PDA) detection method was established for the simultaneous determination of 12 components in Xiao-Yao-San-Jia-Wei (XYSJW): geniposide, puerarin, paeoniflorin, ferulic acid, liquiritin, hesperidin, naringin, paeonol, daidzein, glycyrrhizic acid, honokiol, and magnolol. These were separated in less than 70 min using a Waters Symmetry Shield RP 18 column with gradient elution using (A) acetonitrile, (B) water, and (C) acetic acid at a flow rate of 1 ml/min, and with a PDA detector. All calibration curves showed good linear regression (r(2)>0.9992) within the test ranges. The method was validated for specificity, accuracy, precision, and limits of detection. The proposed method enables in a single run the simultaneous identification and determination for quality control of 12 multi-structural components of XYSJW forming the basis of its therapeutic effect.

  4. Rapid determination of ampicillin in bovine milk by liquid chromatography with fluorescence detection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ang, C.Y.W.; Luo, Wenhong

    1997-01-01

    A rapid and sensitive liquid chromatographic (LC) method was developed for the determination of ampicillin residues in raw bovine milk, processed skim milk, and pasteurized, homogenized whole milk with vitamin D. Milk samples were deproteinized with trichloroacetic acid (TCA) and acetonictrile. After centrifugation, the clear supernatant was reacted with formaldehyde and TCA under heat. The major fluorescent derivative of ampicillin was then determined by reversed-phase LC with fluorescence detection. Average recoveries of ampicillin fortified at 5, 10, and 20 ppb (ng/mL) were all >85% with coefficients of variation <10%. Limits of detection ranged from 0.31 to 0.51 ppb and limitsmore » of quantitation, from 0.66 to 1.2 ppb. After appropriate validation, this method should be suitable for rapid analysis of milk for ampicillin residues at the tolerance level of 10 ppb. 16 refs., 4 figs., 3 tabs.« less

  5. Determination of phenolic constituents of biological interest in red wine by capillary electrophoresis with electrochemical detection.

    PubMed

    Peng, Youyuan; Chu, Qingcui; Liu, Fanghua; Ye, Jiannong

    2004-01-28

    A simultaneous determination of trans-resveratrol, (-)-epicatechin, and (+)-catechin in red wine by capillary electrophoresis with electrochemical detection (CE-ED) is reported. The effects of the potential of the working electrode, pH and concentration of running buffer, separation voltage, and injection time on CE-ED were investigated. Under the optimum conditions, the analytes could be separated in a 100 mmol/L borate buffer (pH 9.2) within 20 min. A 300 microm diameter carbon disk electrode has a good response at +0.85 V (vs SCE) for all analytes. The response was linear over 3 orders of magnitude with detection limit (S/N = 3) ranging from 2 x 10(-7) to 5 x 10(-7) g/mL for all analytes. This method has been used for the determination of these analytes in red wine without enrichment, and the assay result was satisfactory.

  6. [Detection of the preservative chlorphenesin in cosmetics by high-performance liquid chromatography].

    PubMed

    Ikarashi, Yoshiaki; Miyazawa, Norimasa; Shimamura, Kimio; Sato, Nobuo; Yoshizawa, Ken-ichi; Hayashi, Masahito; Takano, Katsuhiro; Miyamoto, Michiko; Kojima, Takashi; Sakaguchi, Hiroshi; Fujiio, Makiko

    2009-01-01

    A simple determination method for preservative chlorphenesin in cosmetics was developed. Cosmetic samples were dissolved in methanol. The sample solution was analyzed by high-performance liquid chromatography (HPLC) with ODS column, using water-methanol (55:45) or water-acetonitrile (3:1) adjusted to pH 2.5 with phosphoric acid as the mobile phase. Chlorphenesin was detected with ultraviolet light detection at 280 nm. A linear relation was obtained between the peak areas and the concentrations of chlorphenesin in the range of 1-500 microg/ml. The determination limit of chlorphenesin was 1-2 microg/ml. Recoveries of chlorphenesin spiked in lotion and milky lotion at the levels of 0.03% and 0.3% were 98.8-100.0%. This method was applied for cosmetics including 0.03% and 0.3% of chlorphenesin and their content corresponded with the determined values.

  7. Automated Meteor Fluxes with a Wide-Field Meteor Camera Network

    NASA Technical Reports Server (NTRS)

    Blaauw, R. C.; Campbell-Brown, M. D.; Cooke, W.; Weryk, R. J.; Gill, J.; Musci, R.

    2013-01-01

    Within NASA, the Meteoroid Environment Office (MEO) is charged to monitor the meteoroid environment in near ]earth space for the protection of satellites and spacecraft. The MEO has recently established a two ]station system to calculate automated meteor fluxes in the millimeter ]size ]range. The cameras each consist of a 17 mm focal length Schneider lens on a Watec 902H2 Ultimate CCD video camera, producing a 21.7 x 16.3 degree field of view. This configuration has a red ]sensitive limiting meteor magnitude of about +5. The stations are located in the South Eastern USA, 31.8 kilometers apart, and are aimed at a location 90 km above a point 50 km equidistant from each station, which optimizes the common volume. Both single station and double station fluxes are found, each having benefits; more meteors will be detected in a single camera than will be seen in both cameras, producing a better determined flux, but double station detections allow for non ]ambiguous shower associations and permit speed/orbit determinations. Video from the cameras are fed into Linux computers running the ASGARD (All Sky and Guided Automatic Real ]time Detection) software, created by Rob Weryk of the University of Western Ontario Meteor Physics Group. ASGARD performs the meteor detection/photometry, and invokes the MILIG and MORB codes to determine the trajectory, speed, and orbit of the meteor. A subroutine in ASGARD allows for the approximate shower identification in single station meteors. The ASGARD output is used in routines to calculate the flux in units of #/sq km/hour. The flux algorithm employed here differs from others currently in use in that it does not assume a single height for all meteors observed in the common camera volume. In the MEO system, the volume is broken up into a set of height intervals, with the collecting areas determined by the radiant of active shower or sporadic source. The flux per height interval is summed to obtain the total meteor flux. As ASGARD also computes the meteor mass from the photometry, a mass flux can be also calculated. Weather conditions in the southeastern United States are seldom ideal, which introduces the difficulty of a variable sky background. First a weather algorithm indicates if sky conditions are clear enough to calculate fluxes, at which point a limiting magnitude algorithm is employed. The limiting magnitude algorithm performs a fit of stellar magnitudes vs camera intensities. The stellar limiting magnitude is derived from this and easily converted to a limiting meteor magnitude for the active shower or sporadic source.

  8. The Need and Potential of Biosensors to Detect Dioxins and Dioxin-Like Polychlorinated Biphenyls along the Milk, Eggs and Meat Food Chain

    PubMed Central

    Chobtang, Jeerasak; de Boer, Imke J. M.; Hoogenboom, Ron L. A. P.; Haasnoot, Willem; Kijlstra, Aize; Meerburg, Bastiaan G.

    2011-01-01

    Dioxins and dioxin-like polychlorinated biphenyls (DL-PCBs) are hazardous toxic, ubiquitous and persistent chemical compounds, which can enter the food chain and accumulate up to higher trophic levels. Their determination requires sophisticated methods, expensive facilities and instruments, well-trained personnel and expensive chemical reagents. Ideally, real-time monitoring using rapid detection methods should be applied to detect possible contamination along the food chain in order to prevent human exposure. Sensor technology may be promising in this respect. This review gives the state of the art for detecting possible contamination with dioxins and DL-PCBs along the food chain of animal-source foods. The main detection methods applied (i.e., high resolution gas-chromatography combined with high resolution mass-spectrometry (HRGC/HRMS) and the chemical activated luciferase gene expression method (CALUX bioassay)), each have their limitations. Biosensors for detecting dioxins and related compounds, although still under development, show potential to overcome these limitations. Immunosensors and biomimetic-based biosensors potentially offer increased selectivity and sensitivity for dioxin and DL-PCB detection, while whole cell-based biosensors present interpretable biological results. The main shortcoming of current biosensors, however, is their detection level: this may be insufficient as limits for dioxins and DL-PCBs for food and feedstuffs are in pg per gram level. In addition, these contaminants are normally present in fat, a difficult matrix for biosensor detection. Therefore, simple and efficient extraction and clean-up procedures are required which may enable biosensors to detect dioxins and DL-PCBs contamination along the food chain. PMID:22247688

  9. The need and potential of biosensors to detect dioxins and dioxin-like polychlorinated biphenyls along the milk, eggs and meat food chain.

    PubMed

    Chobtang, Jeerasak; de Boer, Imke J M; Hoogenboom, Ron L A P; Haasnoot, Willem; Kijlstra, Aize; Meerburg, Bastiaan G

    2011-01-01

    Dioxins and dioxin-like polychlorinated biphenyls (DL-PCBs) are hazardous toxic, ubiquitous and persistent chemical compounds, which can enter the food chain and accumulate up to higher trophic levels. Their determination requires sophisticated methods, expensive facilities and instruments, well-trained personnel and expensive chemical reagents. Ideally, real-time monitoring using rapid detection methods should be applied to detect possible contamination along the food chain in order to prevent human exposure. Sensor technology may be promising in this respect. This review gives the state of the art for detecting possible contamination with dioxins and DL-PCBs along the food chain of animal-source foods. The main detection methods applied (i.e., high resolution gas-chromatography combined with high resolution mass-spectrometry (HRGC/HRMS) and the chemical activated luciferase gene expression method (CALUX bioassay)), each have their limitations. Biosensors for detecting dioxins and related compounds, although still under development, show potential to overcome these limitations. Immunosensors and biomimetic-based biosensors potentially offer increased selectivity and sensitivity for dioxin and DL-PCB detection, while whole cell-based biosensors present interpretable biological results. The main shortcoming of current biosensors, however, is their detection level: this may be insufficient as limits for dioxins and DL-PCBs for food and feedstuffs are in pg per gram level. In addition, these contaminants are normally present in fat, a difficult matrix for biosensor detection. Therefore, simple and efficient extraction and clean-up procedures are required which may enable biosensors to detect dioxins and DL-PCBs contamination along the food chain.

  10. Determination of 4-nonylphenol and 4-octylphenol in human blood samples by high-performance liquid chromatography with multi-electrode electrochemical coulometric-array detection.

    PubMed

    Inoue, K; Yoshimura, Y; Makino, T; Nakazawa, H

    2000-11-01

    Alkylphenols can affect human health because they disrupt the endocrine system. In this study, an analytical method for determining trace amounts of 4-nonylphenol (NP) and 4-octylphenol (OP) in human blood samples was developed. Reversed-phase HPLC with multi-electrode electrochemical coulometric-array detection was used for the determination of NP and OP in plasma and serum samples prepared with a solid-phase extraction method. The separation was achieved using an isocratic mobile phase of 0.7% phosphoric acid-acetonitrile with a C18 reversed phase column. The detection limits of NP and OP were 1.0 and 0.5 ng ml-1, respectively. The recoveries of NP and OP added to human plasma samples were above 70.0% with a relative standard deviation of less than 15.5%. The method was found to be applicable to the determination of NP and OP in various human blood samples such as serum and plasma.

  11. Visual detection and sequential injection determination of aluminium using a cinnamoyl derivative.

    PubMed

    Elečková, Lenka; Alexovič, Michal; Kuchár, Juraj; Balogh, Ioseph S; Andruch, Vasil

    2015-02-01

    A cinnamoyl derivative, 3-[4-(dimethylamino)cinnamoyl]-4-hydroxy-6-methyl-3,4-2H-pyran-2-one, was used as a ligand for the determination of aluminium. Upon the addition of an acetonitrile solution of the ligand to an aqueous solution containing Al(III) and a buffer solution at pH 8, a marked change in colour from yellow to orange is observed. The colour intensity is proportional to the concentration of Al(III); thus, the 'naked-eye' detection of aluminium is possible. The reaction is also applied for sequential injection determination of aluminium. Beer׳s law is obeyed in the range from 0.055 to 0.66 mg L(-1) of Al(III). The limit of detection, calculated as three times the standard deviation of the blank test (n=10), was found to be 4 μg L(-1) for Al(III). The method was applied for the determination of aluminium in spiked water samples and pharmaceutical preparations. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. Simultaneous determination of rare earth elements in ore and anti-corrosion coating samples using a portable capillary electrophoresis instrument with contactless conductivity detection.

    PubMed

    Nguyen, Thi Anh Huong; Nguyen, Van Ri; Le, Duc Dung; Nguyen, Thi Thanh Binh; Cao, Van Hoang; Nguyen, Thi Kim Dung; Sáiz, Jorge; Hauser, Peter C; Mai, Thanh Duc

    2016-07-29

    The employment of an in-house-made capillary electrophoresis (CE) instrument with capacitively coupled contactless conductivity detection (C(4)D) as a simple and inexpensive solution for simultaneous determination of many rare earth elements (REEs) in ore samples from Vietnam, as well as in anti-corrosion coating samples is reported. 14 REEs (La, Ce, Pr, Nd, Sm, Eu, Gd, Tb, Dy, Ho, Er, Tm, Yb and Lu) were determined using an electrolyte composed of 20mM arginine and 10mM α-hydroxyisobutyric acid adjusted to pH 4.2 with acetic acid. The best detection limit achieved was 0.24mg/L using the developed CE-C(4)D method. Good agreement between results from CE-C(4)D and the confirmation method (ICP-MS) was achieved, with a coefficient of determination (r(2)) for the two pairs of data of 0.998. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Indirect spectrophotometric determination of sodium ceftriaxone with n-propyl alcohol-ammonium sulfate-water system by extraction flotation of copper(II).

    PubMed

    Zhao, Wei; Zhang, Yan; Li, Quanmin

    2008-05-01

    Although the determination methods of sodium ceftriaxone has been increasingly reported, these methods have their inherent limits preventing them from being broadly applied in common laboratories. In order to circumvent this problem, a rapid and simple method for the indirect spectrophotometric determination of sodium ceftriaxone is reported. Sodium ceftriaxone was degraded completely in the presence of 0.20 mol/l sodium hydroxide in boiling water bath for 20 min. The thiol group (-SH) of the degradation product (I) of sodium ceftriaxone could reduce cupric to cuprous ions, and the resulting which was precipitated with the thiol group (-SH) of the degradation product (II) at pH 4.0. By determining the residual amount of copper (II), the indirect determination of sodium ceftriaxone can be achieved. Standard curve of sodium ceftriaxone versus the flotation yield of copper(II) showed that sodium ceftriaxone could be determined in low concentrations. The linear range of sodium ceftriaxone was 0.70-32 microg/ml and the detection limit evaluated by calibration curve (3sigma/k) was found to be 0.60 microg/ml. A simple and efficient method was developed and it has been successfully applied to the determination of sodium ceftriaxone in human serum and urine samples, respectively. It is expected that this method will find broad applications in the detection of cephalosporin derivatives with similar structure.

  14. Detection of Plasmodium knowlesi, Plasmodium falciparum and Plasmodium vivax using loop-mediated isothermal amplification (LAMP) in a co-endemic area in Malaysia.

    PubMed

    Piera, Kim A; Aziz, Ammar; William, Timothy; Bell, David; González, Iveth J; Barber, Bridget E; Anstey, Nicholas M; Grigg, Matthew J

    2017-01-13

    Plasmodium knowlesi is the most common cause of malaria in Malaysia. However, microscopic diagnosis is inaccurate and rapid diagnostic tests (RDTs) are insufficiently sensitive. PCR is sensitive and specific but not feasible at a district level. Loop-mediated isothermal amplification (LAMP) shows potential with only basic requirements. A commercially available LAMP assay, the Eiken Loopamp™ MALARIA Pan Detection kit, is sensitive for Plasmodium falciparum and Plasmodium vivax, but has not previously been evaluated for P. knowlesi. This study aims to determine the sensitivity of this LAMP assay for detecting P. knowlesi infection. Study participants included 73 uncomplicated malaria patients with PCR species confirmation: 50 P. knowlesi, 20 P. falciparum and 3 P. vivax. Nineteen malaria-negative, non-endemic area controls were also included. The sensitivity of the Eiken Loopamp™ MALARIA Pan Detection kit (Pan LAMP) for detecting each Plasmodium species was evaluated. Sensitivity and specificity of the Eiken Loopamp™ MALARIA Pf Detection kit (Pf LAMP) for P. falciparum were also determined. The limit of detection for each LAMP assay was evaluated, with results compared to PCR. All P. knowlesi patients were also tested by CareStart™ (Pf/VOM) and OptiMAL-IT™ (Pan/Pf) RDTs. The sensitivity of the Pan LAMP assay was 100% for P. knowlesi (95% CI 92.9-100), P. falciparum (95% CI 83.2-100), and P. vivax (95% CI 29.2-100). The Pf LAMP was 100% sensitive and specific for P. falciparum detection, with all P. knowlesi samples having a negative reaction. LAMP sensitivity was superior to both RDTs, with only 10 and 28% of P. knowlesi samples testing positive to CareStart™ and OptiMAL-IT™, respectively. Limit of detection using the Pan LAMP for both P. knowlesi and P. vivax was 2 parasites/μL, comparable to PCR. For P. falciparum both the Pan LAMP and Pf LAMP demonstrated a limit of detection of 20 parasites/μL. The Eiken Loopamp™ MALARIA Pan Detection kit is sensitive for detection of P. knowlesi in low parasitaemia clinical infections, as well as P. falciparum and P. vivax. However, a P. knowlesi-specific field assay in a simpler format would assist correct species identification and initiation of optimal treatment for all malaria patients.

  15. ANALYSIS OF SELECTED CHEMICAL GROUPS BY LIQUID CHROMATOGRAPHY/MASS SPECTROMETRY

    EPA Science Inventory

    The use of the moving-belt liquid chromatographic interface in combination with mass spectrometry was evaluated for determining detection limits of selected members of various chemical classes. mong the chemical classes examined were benzidines, nitrosoamines, anilines, nitroarom...

  16. Nano-Infrared Imaging of Amino Acids in Murchison: Sensitivity, Detection Limits, and First Results

    NASA Astrophysics Data System (ADS)

    Salem, M.; Dillon, E.; Dominguez, G.

    2017-07-01

    We apply AFM-tip assisted IR imaging of laboratory standards and Murchison meteorite to identify and map distribution of amino acids and determine sensitivity of AFM-IR to amino-acid functional groups.

  17. Gas chromatographic determination of formaldehyde in maple syrup as 2,4-dinitrophenylhydrazone derivative.

    PubMed

    Baraniak, Z; Nagpal, D S; Neidert, E

    1988-01-01

    A procedure is presented for the quantitative extraction and determination of formaldehyde in maple sap and syrup. The method is based on the reaction between formaldehyde and 2,4-dinitrophenylhydrazine and determination of the derivative by gas chromatography. The procedure was used to evaluate formaldehyde in saps and syrups of paraformaldehyde implanted trees. Average recoveries were 101.5 +/- 5.7%. The detection limit was 0.078 mg/kg.

  18. Quantitation of acrylamide in foods by high-resolution mass spectrometry.

    PubMed

    Troise, Antonio Dario; Fiore, Alberto; Fogliano, Vincenzo

    2014-01-08

    Acrylamide detection still represents one of the hottest topics in food chemistry. Solid phase cleanup coupled to liquid chromatography separation and tandem mass spectrometry detection along with GC-MS detection are nowadays the gold standard procedure for acrylamide quantitation thanks to high reproducibility, good recovery, and low relative standard deviation. High-resolution mass spectrometry (HRMS) is particularly suitable for the detection of low molecular weight amides, and it can provide some analytical advantages over other MS techniques. In this paper a liquid chromatography (LC) method for acrylamide determination using HRMS detection was developed and compared to LC coupled to tandem mass spectrometry. The procedure applied a simplified extraction, no cleanup steps, and a 4 min chromatography. It proved to be solid and robust with an acrylamide mass accuracy of 0.7 ppm, a limit of detection of 2.65 ppb, and a limit of quantitation of 5 ppb. The method was tested on four acrylamide-containing foods: cookies, French fries, ground coffee, and brewed coffee. Results were perfectly in line with those obtained by LC-MS/MS.

  19. Highly sensitive on-site detection of glucose in human urine with naked eye based on enzymatic-like reaction mediated etching of gold nanorods.

    PubMed

    Zhang, Zhiyang; Chen, Zhaopeng; Cheng, Fangbin; Zhang, Yaowen; Chen, Lingxin

    2017-03-15

    Based on enzymatic-like reaction mediated etching of gold nanorods (GNRs), an ultrasensitive visual method was developed for on-site detection of urine glucose. With the catalysis of MoO 4 2 - , GNRs were efficiently etched by H 2 O 2 which was generated by glucose-glucose oxidase enzymatic reaction. The etching of GNRs lead to a blue-shift of logitudinal localized surface plasmon resonance of GNRs, accompanied by an obvious color change from blue to red. The peak-shift and the color change can be used for detection of glucose by the spectrophotometer and the naked eyes. Under optimal condition, an excellent sensitivity toward glucose is obtained with a detection limit of 0.1μM and a visual detection limit of 3μM in buffer solution. Benefiting from the high sensitivity, the successful colorimetric detection of glucose in original urine samples was achieved, which indicates the practical applicability to the on-site determination of urine glucose. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Iodine-Mediated Etching of Gold Nanorods for Plasmonic ELISA Based on Colorimetric Detection of Alkaline Phosphatase.

    PubMed

    Zhang, Zhiyang; Chen, Zhaopeng; Wang, Shasha; Cheng, Fangbin; Chen, Lingxin

    2015-12-23

    Here, we propose a plasmonic enzyme-linked immunosorbent assay (ELISA) based on highly sensitive colorimetric detection of alkaline phosphatase (ALP), which is achieved by iodine-mediated etching of gold nanorods (AuNRs). Once the sandwich-type immunocomplex is formed, the ALP bound on the polystyrene microwells will hydrolyze ascorbic acid 2-phosphate into ascorbic acid. Subsequently, iodate is reduced to iodine, a moderate oxidant, which etches AuNRs from rod to sphere in shape. The shape change of AuNRs leads to a blue-shift of longitudinal localized surface plasmon resonance. As a result, the solution of AuNRs changes from blue to red. Benefiting from the highly sensitive detection of ALP, the proposed plasmonic ELISA has achieved an ultralow detection limit (100 pg/mL) for human immunoglobulin G (IgG). Importantly, the visual detection limit (3.0 ng/mL) allows the rapid differential diagnosis with the naked eye. The further detection of human IgG in fetal bovine serum indicates its applicability to the determination of low abundance protein in complex biological samples.

  1. 40 CFR Appendix B to Part 136 - Definition and Procedure for the Determination of the Method Detection Limit-Revision 1.11

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... that the analyte concentration is greater than zero and is determined from analysis of a sample in a given matrix containing the analyte. Scope and Application This procedure is designed for applicability to a wide variety of sample types ranging from reagent (blank) water containing analyte to wastewater...

  2. 40 CFR Appendix B to Part 136 - Definition and Procedure for the Determination of the Method Detection Limit-Revision 1.11

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... that the analyte concentration is greater than zero and is determined from analysis of a sample in a given matrix containing the analyte. Scope and Application This procedure is designed for applicability to a wide variety of sample types ranging from reagent (blank) water containing analyte to wastewater...

  3. 40 CFR Appendix B to Part 136 - Definition and Procedure for the Determination of the Method Detection Limit-Revision 1.11

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... that the analyte concentration is greater than zero and is determined from analysis of a sample in a given matrix containing the analyte. Scope and Application This procedure is designed for applicability to a wide variety of sample types ranging from reagent (blank) water containing analyte to wastewater...

  4. The Evolution of the Multiplicity of Embedded Protostars. I. Sample Properties and Binary Detections

    NASA Astrophysics Data System (ADS)

    Connelley, Michael S.; Reipurth, Bo; Tokunaga, Alan T.

    2008-06-01

    We present the observational results of a near-infrared survey of a large sample of Class I protostars designed to determine the Class I binary separation distribution from ~100 AU to ~5000 AU. We have selected targets from a new sample of 267 nearby candidate Class I objects. This sample is well understood, consists of mostly Class I young stellar objects (YSOs) within 1 kpc, has targets selected from the whole sky, and is not biased by previous studies of star formation. We have observed 189 Class I YSOs north of δ = -40° at the H, K, and L' bands, with a median angular resolution of 0farcs33 at L'. We determine our detection limit for close binary companions by observing artificial binaries. We choose a contrast limit and an outer detection limit to minimize contamination and to ensure that a candidate companion is gravitationally bound. Our survey uses observations at the L' rather than the K band for the detection of binary companions since there is less scattered light and better seeing at L'. This paper presents the positions of our targets, the near-IR photometry of sources detected in our fields at L', as well as the observed properties of the 89 detected companions (73 of which are newly discovered). Although we have chosen contrast and separation limits to minimize contamination, we expect that there are about six stars identified as binary companions that are due to contamination. Finder charts at L' for each field are shown to facilitate future studies of these objects. The Infrared Telescope Facility is operated by the University of Hawaii under Cooperative Agreement no. NCC 5-538 with the National Aeronautics and Space Administration, Science Mission Directorate, Planetary Astronomy Program. The United Kingdom Infrared Telescope is operated by the Joint Astronomy Centre on behalf of the Science and Technology Facilities Council of the U.K. Based in part on data collected at the Subaru Telescope, which is operated by the National Astronomical Observatory of Japan.

  5. Ion pair-based dispersive liquid-liquid microextraction followed by high performance liquid chromatography as a new method for determining five folate derivatives in foodstuffs.

    PubMed

    Nojavan, Yones; Kamankesh, Marzieh; Shahraz, Farzaneh; Hashemi, Maryam; Mohammadi, Abdorreza

    2015-05-01

    A novel technique for simultaneous determination of five folate derivatives in various food matrices was developed by ion pair-based dispersive liquid-liquid microextraction (IP-DLLME) combined with high-performance liquid chromatography (HPLC). In the proposed method, N-methyl-N,N-dioctyloctan-1-ammonium chloride (aliquat-336) was used as an ion-pair reagent. Effective variables of microextraction process were optimized. Under optimum conditions, the method yielded a linear calibration curve ranging from 1-200 ng g(-1) with correlation coefficients (r(2)) higher than 0.98. The relative standard deviation for the seven analyses was 5.2-7.4%. Enrichment factors for the five folates ranged between 108-135. Limits of detection were 2-4.1 ng g(-1). A comparison of this method with other methods described that the new proposed method is rapid and accurate, and gives very good enrichment factors and detection limits for determining five folate derivatives. The newly developed method was successfully applied for the determination of five folate derivatives in wheat flour, egg yolk and orange juice samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Analytical possibilities of different X-ray fluorescence systems for determination of trace elements in aqueous samples pre-concentrated with carbon nanotubes

    NASA Astrophysics Data System (ADS)

    Marguí, E.; Zawisza, B.; Skorek, R.; Theato, T.; Queralt, I.; Hidalgo, M.; Sitko, R.

    2013-10-01

    This study was aimed to achieve improved instrumental sensitivity and detection limits for multielement determination of V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Ga, Se, Pb and Cd in liquid samples by using different X-ray fluorescence (XRF) configurations (a benchtop energy-dispersive X-ray fluorescence spectrometer, a benchtop polarised energy-dispersive X-ray fluorescence spectrometer and a wavelength-dispersive X-ray fluorescence spectrometer). The preconcentration of metals from liquid solutions consisted on a solid-phase extraction using carbon nanotubes (CNTs) as solid sorbents. After the extraction step, the aqueous sample was filtered and CNTs with the absorbed elements were collected onto a filter paper which was directly analyzed by XRF. The calculated detection limits in all cases were in the low ng mL- 1 range. Nevertheless, results obtained indicate the benefits, in terms of sensitivity, of using polarized X-ray sources using different secondary targets in comparison to conventional XRF systems, above all if Cd determination is required. The developed methodologies, using the aforementioned equipments, have been applied for multielement determination in water samples from an industrial area of Poland.

  7. Evaluation and application of microwave-assisted extraction and dispersive liquid-liquid microextraction followed by high-performance liquid chromatography for the determination of polar heterocyclic aromatic amines in hamburger patties.

    PubMed

    Aeenehvand, Saeed; Toudehrousta, Zahra; Kamankesh, Marzieh; Mashayekh, Morteza; Tavakoli, Hamid Reza; Mohammadi, Abdorreza

    2016-01-01

    This study developed an analytical method based on microwave-assisted extraction and dispersive liquid-liquid microextraction followed by high-performance liquid chromatography for the determination of three polar heterocyclic aromatic amines from hamburger patties. Effective parameters controlling the performance of the microextraction process, such as the type and volume of extraction and disperser solvents, microwave time, nature of alkaline aqueous solution, pH and salt amount, were optimized. The calibration graphs were linear in the range of 1-200 ng g(-1), with a coefficient of determination (R(2)) better than 0.9993. The relative standard deviations (RSD) for seven analyses were between 3.2% and 6.5%. The recoveries of those compounds in hamburger patties were from 90% to 105%. Detection limits were between 0.06 and 0.21 ng g(-1). A comparison of the proposed method with the existing literature demonstrates that it is a simple, rapid, highly selective and sensitive, and it gives good enrichment factors and detection limits for determining HAAs in real hamburger patties samples. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Determination of linear aliphatic aldehydes in heavy metal containing waters by high-performance liquid chromatography using 2,4-dinitrophenylhydrazine derivatization.

    PubMed

    Lin, Yi-Liang; Wang, Po-Yen; Hsieh, Ling-Ling; Ku, Kuan-Hsuan; Yeh, Yun-Tai; Wu, Chien-Hou

    2009-09-04

    A simple and sensitive method is described for the determination of picomolar amounts of C(1)-C(9) linear aliphatic aldehydes in waters containing heavy metal ions. In this method, aldehydes were first derivatized with 2,4-dinitrophenylhydrazine (DNPH) at optimized pH 1.8 for 30 min and analyzed by HPLC with UV detector at 365 nm. Factors affecting the derivatization reaction of aldehydes and DNPH were investigated. Cupric ion, an example of heavy metals, is a common oxidative reagent, which may oxidize DNPH and greatly interfere with the determination of aldehydes. EDTA was used to effectively mask the interferences by heavy metal ions. The method detection limits for direct injection of derivatized most aldehydes except formaldehyde were of the order of 7-28 nM. The detection limit can be further lowered by using off-line C(18) adsorption cartridge enrichment. The recoveries of C(1)-C(9) aldehydes were 93-115% with a relative standard deviation of 3.6-8.1% at the 0.1 microM level for aldehydes. The HPLC-DNPH method has been applied for determining aldehyde photoproducts from Cu(II)-amino acid complex systems.

  9. Derivatization Ion Chromatography for the Determination of Monoethanolamine in Presence of Hydrazine in PHWR Steam-Water Circuits

    PubMed Central

    D., Ayushi; Sengupta, Arijit; Kumar, Sangita D.; Kumbhar, A. G.; Venkateswaran, G.

    2011-01-01

    A simple, rapid and accurate method for the determination of monoethanolamine (MEA) in PHWR steam-water circuits has been developed. MEA is added in the feed water to provide protection against corrosion while hydrazine is added to scavenge dissolved oxygen. The quantitative determination of MEA in presence of hydrazine was accomplished using derivatization ion chromatography with conductometric detection in nonsuppressed mode. A Metrosep cation 1-2 analytical column and a Metrosep cartridge were used for cation separation. A mixture of 4 mM tartaric acid, 20% acetone and 0.05 mM HNO3 was used as eluent. Acetone in the mobile phase leads to the formation of different derivatives with MEA and hydrazine. The interferences due Na+ and NH4  + were eliminated by adopting a simple pretreatment procedure employing OnGuard-H cartridge. The limit of detection limit of MEA was 0.1 μg mL−1 and the relative standard deviation was 2% for the overall method. The recovery of MEA added was in the range 95%–102%. The method was applied to the determination of MEA in steam generator water samples. PMID:21785596

  10. Rapid Diagnostic Tests for Identifying Avian Influenza A(H7N9) Virus in Clinical Samples

    PubMed Central

    Chen, Yu; Wang, Dayan; Zheng, Shufa; Shu, Yuelong; Chen, Wenxiang; Cui, Dawei; Li, Jinming; Yu, Hongjie; Wang, Yu; Li, Lanjuan

    2015-01-01

    To determine sensitivity of rapid diagnostic tests for detecting influenza A(H7N9) virus, we compared rapid tests with PCR results and tested different types of clinical samples. Usefulness of seasonal influenza rapid tests for A(H7N9) virus infections is limited because of their low sensitivity for detecting virus in upper respiratory tract specimens. PMID:25529064

  11. A validated high-performance liquid chromatography method with diode array detection for simultaneous determination of nine flavonoids in Senecio cannabifolius Less.

    PubMed

    Niu, Tian-Zeng; Zhang, Yu-Wei; Bao, Yong-Li; Wu, Yin; Yu, Chun-Lei; Sun, Lu-Guo; Yi, Jing-Wen; Huang, Yan-Xin; Li, Yu-Xin

    2013-03-25

    A reversed phase high performance liquid chromatography method coupled with a diode array detector (HPLC-DAD) was developed for the first time for the simultaneous determination of 9 flavonoids in Senecio cannabifolius, a traditional Chinese medicinal herb. Agilent Zorbax SB-C18 column was used at room temperature and the mobile phase was a mixture of acetonitrile and 0.5% formic acid (v/v) in water in the gradient elution mode at a flow-rate of 1.0mlmin(-1), detected at 360nm. Validation of this method was performed to verify the linearity, precision, limits of detection and quantification, intra- and inter-day variabilities, reproducibility and recovery. The calibration curves showed good linearities (R(2)>0.9995) within the test ranges. The relative standard deviation (RSD) of the method was less than 3.0% for intra- and inter-day assays. The samples were stable for at least 96h, and the average recoveries were between 90.6% and 102.5%. High sensitivity was demonstrated with detection limits of 0.028-0.085μg/ml for flavonoids. The newly established HPLC method represents a powerful technique for the quality assurance of S. cannabifolius. Copyright © 2012 Elsevier B.V. All rights reserved.

  12. The development of a MIP-optosensor for the detection of monoamine naphthalenes in drinking water.

    PubMed

    Valero-Navarro, Angel; Salinas-Castillo, Alfonso; Fernández-Sánchez, Jorge F; Segura-Carretero, Antonio; Mallavia, Ricardo; Fernández-Gutiérrez, Alberto

    2009-03-15

    To enhance the advantages of fluorescent flow-through sensing for drinking water we have designed a novel sensing matrix based on molecularly imprinted polymers (MIPs). The synergic combination of a tailor-made MIP recognition with a selective room temperature fluorescence detection is a novel concept for optosensing devices and is assessed here for the simple and selective determination of pollutants in water. We describe a simple approach to preparing synthetic receptors for monoamine naphthalene compounds (MA-NCs) using non-covalent molecular imprinting techniques and naphthalene as template. We examine in detail the binding characteristics of the imprinted polymer and describe the flow-through sensor of MA-NCs by solid-surface fluorescence. Its detection limits for recognizing 1-naphthylamine (1-NA) and 2-naphthylamine (2-NA) separately are 26 ngmL(-1) and 50 ngmL(-1), respectively, and it also determines 1-NA and 2-NA simultaneously with a detection limit of 45 ngmL(-1). All the instrumental, chemical and flow variables were carefully optimized and an interference study was carried out to demonstrate its applicability and selectivity. Finally, we applied it to the analysis of 1-NA and 2-NA in tap and mineral waters, obtaining a 98% average recovery rate.

  13. Determination of moclobemide in human plasma by high-performance liquid chromatography with spectrophotometric detection.

    PubMed

    Amini, Hossein; Shahmir, Badri; Ahmadiani, Abolhassan

    2004-08-05

    A simple and sensitive high-performance liquid chromatographic (HPLC) method with spectrophotometric detection was developed for the determination of moclobemide in human plasma. Plasma samples were extracted under basic conditions with dichloromethane followed by back-extraction into diluted phosphoric acid. Isocratic separation was employed on an ODS column (250 mm x 4.6 mm, 5 microm) at room temperature. The mobile phase consisted of 5 mM NaH2PO4-acetonitrile-triethylamine (1000:350:10 (v/v/v), pH 3.4). Analyses were run at a flow-rate of 1.0 ml/min and ultraviolet (UV) detection was carried out at 240 nm. The method was specific and sensitive with a quantification limit of 15.6 ng/ml and a detection limit of 5 ng/ml at a signal-to-noise ratio of 3:1. The mean absolute recovery was about 98.2%, while the intra- and inter-day coefficient of variation and percent error values of the assay method were all at acceptable levels. Linearity was assessed in the range of 15.6-2000 ng/ml in plasma with a correlation coefficient of greater than 0.999. This method has been used to analyze several hundred human plasma samples for bioavailibility studies.

  14. Gas chromatographic detection of some nitro explosive compounds in soil samples after solid-phase microextraction with carbon ceramic copper nanoparticle fibers.

    PubMed

    Farhadi, Khalil; Bochani, Shayesteh; Hatami, Mehdi; Molaei, Rahim; Pirkharrati, Hossein

    2014-07-01

    In this research, a new solid-phase microextraction fiber based on carbon ceramic composites with copper nanoparticles followed by gas chromatography with flame ionization detection was applied for the extraction and determination of some nitro explosive compounds in soil samples. The proposed method provides an overview of trends related to synthesis of solid-phase microextraction sorbents and their applications in preconcentration and determination of nitro explosives. The sorbents were prepared by mixing of copper nanoparticles with a ceramic composite produced by mixture of methyltrimethoxysilane, graphite, methanol, and hydrochloric acid. The prepared sorbents were coated on copper wires by dip-coating method. The prepared nanocomposites were evaluated statistically and provided better limits of detection than the pure carbon ceramic. The limit of detection of the proposed method was 0.6 μg/g with a linear response over the concentration range of 2-160 μg/g and square of correlation coefficient >0.992. The new proposed fiber has been demonstrated to be a suitable, inexpensive, and sensitive candidate for extraction of nitro explosive compounds in contaminated soil samples. The constructed fiber can be used more than 100 times without the need for surface generation. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Capillary electrophoresis method with UV-detection for analysis of free amino acids concentrations in food.

    PubMed

    Omar, Mei Musa Ali; Elbashir, Abdalla Ahmed; Schmitz, Oliver J

    2017-01-01

    Simple and inexpensive capillary electrophoresis with UV-detection method (CE-UV) was optimized and validated for determination of six amino acids namely (alanine, asparagine, glutamine, proline, serine and valine) for Sudanese food. Amino acids in the samples were derivatized with 4-chloro-7-nitro-2,1,3-benzoxadiazole (NBD-Cl) prior to CE-UV analysis. Labeling reaction conditions (100mM borate buffer at pH 8.5, labeling reaction time 60min, temperature 70°C and NBD-Cl concentration 40mM) were systematically investigated. The optimal conditions for the separation were 100mM borate buffer at pH 9.7 and detected at 475nm. The method was validated in terms of linearity, limit of detection (LOD), limit of quantification (LOQ), precision (repeatability) (RSD%) and accuracy (recovery). Good linearity was achieved for all amino acids (r(2)>0.9981) in the concentration range of 2.5-40mg/L. The LODs in the range of 0.32-0.56mg/L were obtained. Recoveries of amino acids ranging from 85% to 108%, (n=3) were obtained. The validated method was successfully applied for the determination of amino acids for Sudanese food samples. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Simultaneous determination of 30 hormones illegally added to anti-ageing functional foods using UPLC-MS/MS coupled with SPE clean-up.

    PubMed

    He, Xiaoqin; Xi, Cunxian; Tang, Bobin; Wang, Guomin; Chen, Dongdong; Peng, Tao; Mu, Zhaode

    2014-01-01

    A novel analytical method employing solid-phase extraction (SPE) coupled with ultra-high-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) was developed for the simultaneous determination of 30 hormones in anti-ageing functional foods (capsules, powders and tablets). The analytes were extracted with acetic acid-acetonitrile (1-99 v/v), methanol and acetone, respectively. The extract was purified using a combined column, followed by analyte detection with electrospray ionisation in positive- or negative-ion modes. The results indicated that the 30 compounds had good linear correlations in the range of 1-1000 μg kg⁻¹, and the correlation coefficients were above 0.99. The limits of detection (LOD) and limits of quantification (LOQ) were 0.03-2 and 0.1-5 μg kg⁻¹, respectively. The average recovery of 30 compounds at the three spiked levels varied from 74.7% to 124.1%, and the relative standard deviation (RSD) was 2.4-15.0%. This method was applied to the analysis of hormones in 14 real samples of which seven hormones (such as estrone, dienestrol) were detected in four samples, but the remainder of the hormones were not detected. The developed method is sensitive, efficient, reliable and applicable to real samples.

  17. Microfluidic biosensor for β-Hydroxybutyrate (βHBA) determination of subclinical ketosis diagnosis.

    PubMed

    Weng, Xuan; Zhao, Wenting; Neethirajan, Suresh; Duffield, Todd

    2015-02-12

    Determination of β-hydroxybutyrate (βHBA) is a gold standard for diagnosis of Subclinical Ketosis (SCK), a common disease in dairy cows that causes significant economic loss. Early detection of SCK can help reduce the risk of the disease progressing into clinical stage, thus minimizing economic losses on dairy cattle. Conventional laboratory methods are time consuming and labor-intensive, requiring expensive and bulky equipment. Development of portable and robust devices for rapid on-site SCK diagnosis is an effective way to prevent and control ketosis and can significantly aid in the management of dairy animal health. Microfluidic technology provides a rapid, cost-effective way to develop handheld devices for on-farm detection of sub-clinical ketosis. In this study, a highly sensitive microfluidics-based biosensor for on-site SCK diagnosis has been developed. A rapid, low-cost microfluidic biosensor with high sensitivity and specificity was developed for SCK diagnosis. Determination of βHBA was employed as the indicator in the diagnosis of SCK. On-chip detection using miniaturized and cost-effective optical sensor can be finished in 1 minute with a detection limit of 0.05 mM concentration. Developed microfluidic biosensor was successfully tested with the serum samples from dairy cows affected by SCK. The results of the developed biosensor agreed well with two other laboratory methods. The biosensor was characterized by high sensitivity and specificity towards βHBA with a detection limit of 0.05 mM. The developed microfluidic biosensor provides a promising prototype for a cost-effective handheld meter for on-site SCK diagnosis. By using microfluidic method, the detection time is significantly decreased compared to other laboratory methods. Here, we demonstrate a field-deployable device to precisely identify and measure subclinical ketosis by specific labeling and quantification of β-hydroxybutyate in cow blood samples. A real-time on-site detection system will maximize convenience for the farmers.

  18. Data representing two separate LC-MS methods for detection and quantification of water-soluble and fat-soluble vitamins in tears and blood serum.

    PubMed

    Khaksari, Maryam; Mazzoleni, Lynn R; Ruan, Chunhai; Kennedy, Robert T; Minerick, Adrienne R

    2017-04-01

    Two separate liquid chromatography (LC)-mass spectrometry (MS) methods were developed for determination and quantification of water-soluble and fat-soluble vitamins in human tear and blood serum samples. The water-soluble vitamin method was originally developed to detect vitamins B 1 , B 2 , B 3 (nicotinamide), B 5 , B 6 (pyridoxine), B 7 , B 9 and B 12 while the fat-soluble vitamin method detected vitamins A, D 3 , 25(OH)D 3, E and K 1 . These methods were then validated with tear and blood serum samples. In this data in brief article, we provide details on the two LC-MS methods development, methods sensitivity, as well as precision and accuracy for determination of vitamins in human tears and blood serum. These methods were then used to determine the vitamin concentrations in infant and parent samples under a clinical study which were reported in "Determination of Water-Soluble and Fat-Soluble Vitamins in Tears and Blood Serum of Infants and Parents by Liquid Chromatography/Mass Spectrometry DOI:10.1016/j.exer.2016.12.007 [1]". This article provides more details on comparison of vitamin concentrations in the samples with the ranges reported in the literature along with the medically accepted normal ranges. The details on concentrations below the limits of detection (LOD) and limits of quantification (LOQ) are also discussed. Vitamin concentrations were also compared and cross-correlated with clinical data and nutritional information. Significant differences and strongly correlated data were reported in [1]. This article provides comprehensive details on the data with slight differences or slight correlations.

  19. Electrothermal atomic absorption spectrometric determination of cobalt, copper, lead and nickel traces in aragonite following flotation and extraction separation.

    PubMed

    Zendelovska, D; Pavlovska, G; Cundeva, K; Stafilov, T

    2001-03-30

    A method of determination of Co, Cu, Pb and Ni in nanogram quantities from aragonite is presented. Flotation and extraction of Co, Cu, Pb and Ni is suggested as methods for elimination matrix interferences of calcium. The method of flotation is performed by iron(III) hexamethylenedithiocarbamate, Fe(HMDTC)(3), as a colloid precipitate collector. The liquid-liquid extraction of Co, Cu, Pb and Ni is carried out by sodium diethyldithiocarbamate, NaDDTC, as complexing reagent into methylisobutyl ketone, MIBK. The electrothermal atomic absorption spectrometry (ETAAS) is used for determination of analytes. The detection limits of ETAAS followed by flotation are: 7.8 ng.g(-1) for Co, 17.1 ng.g(-1) for Cu, 7.2 ng.g(-1) for Pb and 9.0 mug.g(-1) for Ni. The detection limits of ETAAS followed by extraction are found to be: 12.0 ng.g(-1) for Co, 51.0 ng.g(-1) for Cu, 24.0 ng.g(-1) for Pb and 21.0 ng.g(-1) for Ni.

  20. Widespread occurrence of low levels of alternariol in apple and tomato products, as determined by comparative immunochemical assessment using monoclonal and polyclonal antibodies.

    PubMed

    Ackermann, Yvonne; Curtui, Valeriu; Dietrich, Richard; Gross, Madeleine; Latif, Hadri; Märtlbauer, Erwin; Usleber, Ewald

    2011-06-22

    This study investigated the production of polyclonal (pAB) antibodies and the first time production of monoclonal (mAB) antibodies against the mycotoxin alternariol, and their implementation in enzyme immunoassay (EIA) for the rapid determination of alternariol in foods. Both EIAs were highly sensitive, with detection limits (IC₂₀) of 35 ± 6.9 pg/mL (mAb EIA) and 59 ± 16 pg/mL (pAb EIA). Food products (n = 109; apple and tomato products, white wine) from German retail shops were analyzed. At a detection limit of 1-2 μg/kg, alternariol at 1-13 μg/kg was found with high frequency in apple (67%) and tomato (93%) products. Tomatoes with visible signs of Alternaria infection, stored at room temperature for up to 4 weeks, contained alternariol at levels up to 50 mg/kg, as determined by EIA and HPLC-FLD. It is concluded that the alternariol immunoassays present a versatile screening tool which could facilitate food control for Alternaria toxins.

  1. [Determination of optical purity of alpha-phenylethylamine by high performance liquid chromatography with pre-column derivatization].

    PubMed

    Wang, Jinzhao; Zeng, Su; Wang, Danhua; Hu, Gongyun

    2009-05-01

    A simple pre-column derivatization-high performance liquid chromatographic (HPLC) method was established for the determination of optical purity of alpha-phenylethylamine. The enantiomers of alpha-phenylethylamine were derivatized with 2,3,4,6-tetra-O-acetyl-beta-D-glucopyranosyl isothiocyanate (GITC). The resulted diastereoisomers were separated on an Agilent Zorbax C18 column (250 mm x 4.6 mm, 5 microm) with a mobile phase of methanol-phosphate buffer (1.36 g/L aqueous solution of potassium dihydrogen phosphate, adjusted to pH 3.0 with concentrated phosphoric acid) (58:42, v/v). The flow rate was set at 1.0 mL/min and the detection wavelength was set at 241 nm. The method was linear from 0.15 - 15.0 mg/L for both enantiomers. The limit of detection and the limit of quantification were 0.05 mg/L and 0.15 mg/L, respectively. The relative standard deviations (RSDs) of inter- and intra-day determination were below 0.5%. The method is easy to handle, accurate, and suitable for the quality control of the optical purity of alpha-phenylethylamine.

  2. Simultaneous Determination of Withanolide A and Bacoside A in Spansules by High-Performance Thin-Layer Chromatography

    PubMed Central

    Shinde, P B; Aragade, P D; Agrawal, M R; Deokate, U A; Khadabadi, S S

    2011-01-01

    The objective of this work was to develop and validate a simple, rapid, precise, and accurate high performance thin layer chromatography method for simultaneous determination of withanolide A and bacoside A in combined dosage form. The stationary phase used was silica gel G60F254. The mobile phase used was mixture of ethyl acetate: methanol: toluene: water (4:1:1:0.5 v/v/v/v). The detection of spots was carried out at 320 nm using absorbance reflectance mode. The method was validated in terms of linearity, accuracy, precision and specificity. The calibration curve was found to be linear between 200 to 800 ng/spot for withanolide A and 50 to 350 ng/spot for bacoside A. The limit of detection and limit of quantification for the withanolide A were found to be 3.05 and 10.06 ng/spot, respectively and for bacoside A 8.3 and 27.39 ng/spot, respectively. The proposed method can be successfully used to determine the drug content of marketed formulation. PMID:22303073

  3. Simultaneous determination of withanolide a and bacoside a in spansules by high-performance thin-layer chromatography.

    PubMed

    Shinde, P B; Aragade, P D; Agrawal, M R; Deokate, U A; Khadabadi, S S

    2011-03-01

    The objective of this work was to develop and validate a simple, rapid, precise, and accurate high performance thin layer chromatography method for simultaneous determination of withanolide A and bacoside A in combined dosage form. The stationary phase used was silica gel G60F(254). The mobile phase used was mixture of ethyl acetate: methanol: toluene: water (4:1:1:0.5 v/v/v/v). The detection of spots was carried out at 320 nm using absorbance reflectance mode. The method was validated in terms of linearity, accuracy, precision and specificity. The calibration curve was found to be linear between 200 to 800 ng/spot for withanolide A and 50 to 350 ng/spot for bacoside A. The limit of detection and limit of quantification for the withanolide A were found to be 3.05 and 10.06 ng/spot, respectively and for bacoside A 8.3 and 27.39 ng/spot, respectively. The proposed method can be successfully used to determine the drug content of marketed formulation.

  4. HPLC and chemometrics-assisted UV-spectroscopy methods for the simultaneous determination of ambroxol and doxycycline in capsule

    NASA Astrophysics Data System (ADS)

    Hadad, Ghada M.; El-Gindy, Alaa; Mahmoud, Waleed M. M.

    2008-08-01

    High-performance liquid chromatography (HPLC) and multivariate spectrophotometric methods are described for the simultaneous determination of ambroxol hydrochloride (AM) and doxycycline (DX) in combined pharmaceutical capsules. The chromatographic separation was achieved on reversed-phase C 18 analytical column with a mobile phase consisting of a mixture of 20 mM potassium dihydrogen phosphate, pH 6-acetonitrile in ratio of (1:1, v/v) and UV detection at 245 nm. Also, the resolution has been accomplished by using numerical spectrophotometric methods as classical least squares (CLS), principal component regression (PCR) and partial least squares (PLS-1) applied to the UV spectra of the mixture and graphical spectrophotometric method as first derivative of the ratio spectra ( 1DD) method. Analytical figures of merit (FOM), such as sensitivity, selectivity, analytical sensitivity, limit of quantitation and limit of detection were determined for CLS, PLS-1 and PCR methods. The proposed methods were validated and successfully applied for the analysis of pharmaceutical formulation and laboratory-prepared mixtures containing the two component combination.

  5. Liquid chromatographic determination of urinary 5-methyl-2'-deoxycytidine and pseudouridine as potential biological markers for leukaemia.

    PubMed

    Zambonin, C G; Aresta, A; Palmisano, F; Specchia, G; Liso, V

    1999-12-01

    A simple reversed-phase liquid chromatographic (LC) method for the determination of urinary 5-methyl-2'-deoxycytidine (m5dCyd), recently claimed (on the basis of an imuno-technique) to be a potential marker for leukaemia, has been developed. Sample pre-treatment is based on a microcolumn clean-up step with an average recovery of 79% and a RSD of 3%. Detection limit was 0.2 microg/ml which is about tenfold lower than levels previously measured by an ELISA method in urine of healthy individuals. The creatinine (Cre) excretion, necessary for normalising the m5dCyd excretion, was evaluated by ion-pair liquid chromatography which permitted the simultaneous determination of pseudouridine (psi), a modified nucleoside also potentially useful as a marker for leukaemia. The described LC procedures were applied to the analysis of urine samples from healthy individuals and leukaemia patients. While the urinary psi/Cre ratio was found significantly increased for leukaemia patients, the urinary m5dCyd levels in healthy individuals were below the detection limits and did not increase in presence of the malignant disease.

  6. A simple method for determination of carmine in food samples based on cloud point extraction and spectrophotometric detection.

    PubMed

    Heydari, Rouhollah; Hosseini, Mohammad; Zarabi, Sanaz

    2015-01-01

    In this paper, a simple and cost effective method was developed for extraction and pre-concentration of carmine in food samples by using cloud point extraction (CPE) prior to its spectrophotometric determination. Carmine was extracted from aqueous solution using Triton X-100 as extracting solvent. The effects of main parameters such as solution pH, surfactant and salt concentrations, incubation time and temperature were investigated and optimized. Calibration graph was linear in the range of 0.04-5.0 μg mL(-1) of carmine in the initial solution with regression coefficient of 0.9995. The limit of detection (LOD) and limit of quantification were 0.012 and 0.04 μg mL(-1), respectively. Relative standard deviation (RSD) at low concentration level (0.05 μg mL(-1)) of carmine was 4.8% (n=7). Recovery values in different concentration levels were in the range of 93.7-105.8%. The obtained results demonstrate the proposed method can be applied satisfactory to determine the carmine in food samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. HPLC and chemometrics-assisted UV-spectroscopy methods for the simultaneous determination of ambroxol and doxycycline in capsule.

    PubMed

    Hadad, Ghada M; El-Gindy, Alaa; Mahmoud, Waleed M M

    2008-08-01

    High-performance liquid chromatography (HPLC) and multivariate spectrophotometric methods are described for the simultaneous determination of ambroxol hydrochloride (AM) and doxycycline (DX) in combined pharmaceutical capsules. The chromatographic separation was achieved on reversed-phase C(18) analytical column with a mobile phase consisting of a mixture of 20mM potassium dihydrogen phosphate, pH 6-acetonitrile in ratio of (1:1, v/v) and UV detection at 245 nm. Also, the resolution has been accomplished by using numerical spectrophotometric methods as classical least squares (CLS), principal component regression (PCR) and partial least squares (PLS-1) applied to the UV spectra of the mixture and graphical spectrophotometric method as first derivative of the ratio spectra ((1)DD) method. Analytical figures of merit (FOM), such as sensitivity, selectivity, analytical sensitivity, limit of quantitation and limit of detection were determined for CLS, PLS-1 and PCR methods. The proposed methods were validated and successfully applied for the analysis of pharmaceutical formulation and laboratory-prepared mixtures containing the two component combination.

  8. Simultaneous determination of hydroquinone and catechol at gold nanoparticles mesoporous silica modified carbon paste electrode.

    PubMed

    Tashkhourian, J; Daneshi, M; Nami-Ana, F; Behbahani, M; Bagheri, A

    2016-11-15

    A new electrochemical sensor based on gold nanoparticles mesoporous silica modified carbon paste electrode (AuNPs-MPS) was developed for simultaneous determination of hydroquinone and catechol. Morphology and structure of the AuNPs-MPS were characterized by transmission electron microscopy, X-ray diffraction and Fourier transform infrared spectroscopy. The electrochemical behavior of hydroquinone and catechol were investigated using square wave voltammetry and the results indicate that the electrochemical responses are improved significantly at the modified electrode. The observed oxidative peaks separation of about 120mV made possible the simultaneous determination of hydroquinone and catechol in their binary-mixture. Under the optimized condition, a linear dynamic range of 10.0μM-1.0mM range for hydroquinone with the detection limit of 1.2μM and from 30.0μM-1.0mM for catechol with the detection limit of 1.1μM were obtained. The applicability of the method was demonstrated by the recovery studies of hydroquinone and catechol in spiked tap water samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Application of an ETV-ICP system for the determination of elements in human hair*1

    NASA Astrophysics Data System (ADS)

    Plantikow-Voβgätter, F.; Denkhaus, E.

    1996-01-01

    When determining element contents in hair samples without sample digestion it is necessary to analyze large sample volumes in order to minimize problems of inhomogeneity of biological sample materials. Therefore an electrothermal vaporization system (ETV) is used for solid sample introduction into an inductively coupled plasma (ICP) for the determination of matrix and trace elements in hair. This paper concentrates on the instrumental aspects without time consuming sample preparation. The results obtained for optimization tests, ETV operating parameters and ICP operating parameters, are shown and discussed. Standard additions are used for calibration for the determination of Zn, Mg, and Mn in human hair. Studies including reproducibility and detection limits for chosen elements have been carried out on certified reference materials (CRMs). The determination of reproducibility (relative standard deviation (RSD) of n = 10) and detection limits (DLs) of Zn (RSD < 8.5%, DL < 0.8 μ g -1), Mn (RSD < 14.1%, DL < 0.3 μ g -1), and Mg (RSD < 7.4%, DL < 6.6 μ g -1) are satisfactory. The concentration values found show good agreement with the corresponding certified values. Further sample preparation steps, including hair sampling, washing procedure and homogenization for hair, relating to measurements of real hair samples are described.

  10. Trace analysis of high-purity graphite by LA-ICP-MS.

    PubMed

    Pickhardt, C; Becker, J S

    2001-07-01

    Laser-ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) has been established as a very efficient and sensitive technique for the direct analysis of solids. In this work the capability of LA-ICP-MS was investigated for determination of trace elements in high-purity graphite. Synthetic laboratory standards with a graphite matrix were prepared for the purpose of quantifying the analytical results. Doped trace elements, concentration 0.5 microg g(-1), in a laboratory standard were determined with an accuracy of 1% to +/- 7% and a relative standard deviation (RSD) of 2-13%. Solution-based calibration was also used for quantitative analysis of high-purity graphite. It was found that such calibration led to analytical results for trace-element determination in graphite with accuracy similar to that obtained by use of synthetic laboratory standards for quantification of analytical results. Results from quantitative determination of trace impurities in a real reactor-graphite sample, using both quantification approaches, were in good agreement. Detection limits for all elements of interest were determined in the low ng g(-1) concentration range. Improvement of detection limits by a factor of 10 was achieved for analyses of high-purity graphite with LA-ICP-MS under wet plasma conditions, because the lower background signal and increased element sensitivity.

  11. Determination of the volume activity concentration of alpha artificial radionuclides with alpha spectrometer.

    PubMed

    Liu, B; Zhang, Q; Li, Y

    1997-12-01

    This paper introduces a method to determine the volume activity concentration of alpha and/or beta artificial radionuclides in the environment and radon/thoron progeny background-compensation based on a Si surface-barrier detector. By measuring the alpha peak counts of 218Po and 214Po in two time intervals, the activity concentration of 218Po, 214Pb and 214Bi aerosol particles were determined; meanwhile, the total beta count of 214Pb and 214Bi aerosols was also calculated from their decay scheme. With the average equilibrium factor of thoron progeny in general environment, the alpha and beta counts of thoron progeny were approximately evaluated by 212Po alpha peak counts. The alpha count of transuranic aerosols was determined by subtracting the trail counts of radon/thoron progeny alpha peaks. The total count of beta artificial radionuclides was determined by subtracting the beta counts of radon/thoron progeny aerosol particles. In our preliminary experiments, if the radon progeny concentration is less than 15 Bq m(-3), the lower limit of detection of transuranics concentration is less than 0.1 Bq m(-3). Even if the radon progeny concentration is as high as 75 Bq m(-3), the lower limit of detection of total beta activity concentration of artificial nuclides aerosols is less than 1 Bq m(-3).

  12. Determination of plutonium and its isotopic ratio in marine sediment samples using quadrupole ICP-MS with the shield torch system under normal plasma conditions.

    PubMed

    Zheng, Jian; Yamada, Masatoshi; Wang, Zhongliang; Aono, Tatsuo; Kusakabe, Masashi

    2004-06-01

    An analytical method for determining (239)Pu and (240)Pu in marine sediment samples, which uses quadrupole ICP-MS, was developed in this work. A simple anion-exchange chromatography system was employed for the separation and purification of Pu from the sample matrix. A sufficient decontamination factor of 1.4 x 10(4) for U, which interferes with the determination of (239)Pu, was achieved. High sensitivity Pu determination was obtained, which led to an extremely low concentration detection limit of approximately 8 fg/ml (0.019 mBq/ml for (239)Pu; 0.071 mBq/ml for (240)Pu) in a sample solution, or an absolute detection limit of 42 fg in a 5 ml sample solution, by using the shield torch technique. Analytical results for the determination of the (239+240)Pu and the (240)Pu/(239)Pu ratio in IAEA 368 (ocean sediment) reference material indicated that the accuracy of the method was satisfactory. The method developed was successfully applied to a study of Pu behavior in the sediments from Sagami Bay, Japan. The observed high (240)Pu/(239)Pu ratio in the sediment core indicated that there was additional Pu input derived from close-in fallout in addition to the global fallout.

  13. Determination of phenformin hydrochloride using molecular imprinting technology coupled with flow-injection chemiluminescence.

    PubMed

    Liu, Zhenbo; Jia, Fengyan; Wang, Wenwen; Wang, Cuixia; Liu, Yongming

    2012-01-01

    A novel method was developed using molecular imprinting technology (MIT) coupled with flow-injection chemiluminescence (FI-CL) for highly sensitive detection of phenformin hydrochloride (PH). The phenformin imprinted polymer was synthesized with methacrylic acid (MAA) as a functional monomer and ethylene glycol dimethacrylate (EGDMA) as a cross-linker. Newly synthesized molecularly imprinted polymer (MIP) particles were packed into a column as a selective recognition element for determination of PH. A CL method for the determination of PH was developed based on the CL reaction of PH with N-bromosuccinimide sensitized by eosin Y in basic media. The optimization of detection conditions was investigated. The CL intensity responded linearly to the concentration of PH in the range 0.09-2.0 µg/mL, with a correlation coefficient of 0.9920. The detection limit was 0.031 µg/mL. The relative standard deviation for the determination of 1.0 µg/mL PH solution was 1.0% (n = 11). The method was applied to the determination of PH in urine samples, with satisfactory results. Copyright © 2011 John Wiley & Sons, Ltd.

  14. Approach for Pesticide Residue Analysis for Metabolite Prothioconazole-desthio in Animal Origin Food.

    PubMed

    Liu, Hui; Yao, Guojun; Liu, Xueke; Liu, Chang; Zhan, Jing; Liu, Donghui; Wang, Peng; Zhou, Zhiqiang

    2017-03-22

    Food safety problems such as damage to immune, nervous, and endocrine systems leading to cancer and malformations have received increasing attention. To achieve the maximum residue limits, the most discussed method of high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) is widely used with a advantage of high precision and resolution. Prothioconazole is a broad-spectrum thiocarbamate fungicide. It can rapidly metabolize to prothioconazole-desthio in different matrixes. Rapid and effective methods for the determination of prothioconazole-desthio in five kinds of different animal food were developed. Samples were extracted with acetonitrile or acetonitrile/water and determined by HPLC-MS/MS. The limit of detection and limit of quantification values of prothioconazole-desthio were 0.015 and 0.05 mg/kg for porcine liver and kidney, 0.0015 and 0.005 mg/kg for pork, and 0.003 and 0.01 mg/kg for eggs, together with 0.0012 and 0.004 mg/kg for milk of the detected method, respectively. A good linear regression trend can be observed in a certain concentration range for all of the animal food. At fortified levels, recoveries were between 83.6 and 105%, with relative standard deviations of 1.5-10.3%. A sample survey of 150 samples with 30 samples for each kind of animal food across the country was conducted and found that there was no prothioconazole-desthio detected in all samples.

  15. Validation and Determination of the Contents of Acetaldehyde and Formaldehyde in Foods

    PubMed Central

    Jeong, Hye-Seung; Chung, Hyun; Song, Sang-Hoon; Kim, Cho-Il; Lee, Joon-Goo

    2015-01-01

    The aim of this study was to develop an efficient quantitative method for the determination of acetaldehyde (AA) and formaldehyde (FA) contents in solid and liquid food matrices. The determination of those compounds was validated and performed using gas chromatography-mass spectrometry combined by solid phase micro-extraction after derivatization with O-(2,3,4,5,6-pentafluoro-benzyl)-hydroxylamine hydrochloride. Validation was carried out in terms of limit of detection, limit of quantitation, linearity, precision, and recovery. Then their contents were analyzed in various food samples including 15 fruits, 22 milk products, 31 alcohol-free beverages, and 13 alcoholic beverages. The highest contents of AA and FA were determined in a white wine (40,607.02 ng/g) and an instant coffee (1,522.46 ng/g), respectively. PMID:26483886

  16. Comparison of ultraviolet detection and charged aerosol detection methods for liquid-chromatographic determination of protoescigenin.

    PubMed

    Filip, Katarzyna; Grynkiewicz, Grzegorz; Gruza, Mariusz; Jatczak, Kamil; Zagrodzki, Bogdan

    2014-01-01

    Escin, a complex mixture of pentacyclic triterpene saponins obtained from horse chestnut seeds extract (HCSE; Aesculus hippocastanum L.), constitutes a traditional herbal active substance of preparations (drugs) used for a treatment of chronic venous insufficiency and capillary blood vessel leakage. A new approach to exploitation of pharmacological potential of this saponin complex has been recently proposed, in which the β-escin mixture is perceived as a source of a hitherto unavailable raw material, pentacyclic triterpene aglycone-protoescigenin. Although many liquid chromatography methods are described in the literature for saponins determination, analysis of protoescigenin is barely mentioned. In this work, a new ultra-high performance liquid chromatography (UHPLC) method developed for protoescigenin quantification has been described. CAD (charged aerosol detection), as a relatively new detection method based on aerosol charging, has been applied in this method as an alternative to ultraviolet (UV) detection. The influence of individual parameters on CAD response and sensitivity was studied. The detection was performed using CAD and UV (200 nm) simultaneously and the results were compared with reference to linearity, accuracy, precision and limit of detection.

  17. Of Detection Limits and Effective Mitigation: The Use of Infrared Cameras for Methane Leak Detection

    NASA Astrophysics Data System (ADS)

    Ravikumar, A. P.; Wang, J.; McGuire, M.; Bell, C.; Brandt, A. R.

    2017-12-01

    Mitigating methane emissions, a short-lived and potent greenhouse gas, is critical to limiting global temperature rise to two degree Celsius as outlined in the Paris Agreement. A major source of anthropogenic methane emissions in the United States is the oil and gas sector. To this effect, state and federal governments have recommended the use of optical gas imaging systems in periodic leak detection and repair (LDAR) surveys to detect for fugitive emissions or leaks. The most commonly used optical gas imaging systems (OGI) are infrared cameras. In this work, we systematically evaluate the limits of infrared (IR) camera based OGI system for use in methane leak detection programs. We analyze the effect of various parameters that influence the minimum detectable leak rates of infrared cameras. Blind leak detection tests were carried out at the Department of Energy's MONITOR natural gas test-facility in Fort Collins, CO. Leak sources included natural gas wellheads, separators, and tanks. With an EPA mandated 60 g/hr leak detection threshold for IR cameras, we test leak rates ranging from 4 g/hr to over 350 g/hr at imaging distances between 5 ft and 70 ft from the leak source. We perform these experiments over the course of a week, encompassing a wide range of wind and weather conditions. Using repeated measurements at a given leak rate and imaging distance, we generate detection probability curves as a function of leak-size for various imaging distances, and measurement conditions. In addition, we estimate the median detection threshold - leak-size at which the probability of detection is 50% - under various scenarios to reduce uncertainty in mitigation effectiveness. Preliminary analysis shows that the median detection threshold varies from 3 g/hr at an imaging distance of 5 ft to over 150 g/hr at 50 ft (ambient temperature: 80 F, winds < 4 m/s). Results from this study can be directly used to improve OGI based LDAR protocols and reduce uncertainty in estimated mitigation effectiveness. Furthermore, detection limits determined in this study can be used as standards to compare new detection technologies.

  18. Production of monoclonal antibody to acaricide dicofol and its derivatives.

    PubMed

    Hongsibsong, Surat; Prapamontol, Tippawan; Suphavilai, Chaisuree; Wipasa, Jiraprapa; Pattarawarapan, Mookda; Kasinrerk, Watchara

    2010-12-01

    In Thailand detection of acaricide dicofol residues has been sporadically performed due to the limitation of analytical techniques. Conventional analytical methods for detecting dicofol residues most often use chromatographic-based techniques. Our ultimate aim is to develop an alternative method for rapidly analyzing dicofol residues in vegetables and fruit samples. Here we report the production of monoclonal antibodies specific to dicofol and its derivatives. Hapten-protein carriers were prepared by linking succinic anhydride to dichlorobenzhydrol (DCBH), which was then conjugated to bovine serum albumin (BSA) and oval albumin (OVA). DCBH-BSA conjugate was used as immunogen while DCBH-OVA conjugate was used as capture antigen for competitive inhibition assay. Female BALB/c mice were immunized with DCBH-BSA conjugate subcutaneously, and antibody (Ab) level was determined 2 weeks after the last immunization. Spleen cells producing high titer antibody were isolated and fused with myeloma cells of P3.X6.Ag8.653. After limiting dilutions, antibody produced by one clone had high affinity, which was found to be of IgG1 with κ light chain. Specificity and inhibition concentrations of the monoclonal antibody (MAb) were determined by competitive indirect ELISA with dicofol, and its 50% (IC(50)) was 0.28 μg/mL. Working ranges of the developed immunoassay were from 0.07 to 25 μg/mL. Hence, the prepared MAb will be able to be applied for immunoassay development for detecting dicofol residue in vegetables and fruits far below the maximum residue limit such that 5 g of fruits and berries can be detected below 0.1 mg/kg.

  19. Paramagnetic particles coupled with an automated flow injection analysis as a tool for influenza viral protein detection.

    PubMed

    Krejcova, Ludmila; Dospivova, Dana; Ryvolova, Marketa; Kopel, Pavel; Hynek, David; Krizkova, Sona; Hubalek, Jaromir; Adam, Vojtech; Kizek, Rene

    2012-11-01

    Currently, the influenza virus infects millions of individuals every year. Since the influenza virus represents one of the greatest threats, it is necessary to develop a diagnostic technique that can quickly, inexpensively, and accurately detect the virus to effectively treat and control seasonal and pandemic strains. This study presents an alternative to current detection methods. The flow-injection analysis-based biosensor, which can rapidly and economically analyze a wide panel of influenza virus strains by using paramagnetic particles modified with glycan, can selectively bind to specific viral A/H5N1/Vietnam/1203/2004 protein-labeled quantum dots. Optimized detection of cadmium sulfide quantum dots (CdS QDs)-protein complexes connected to paramagnetic microbeads was performed using differential pulse voltammetry on the surface of a hanging mercury drop electrode (HMDE) and/or glassy carbon electrode (GCE). Detection limit (3 S/N) estimations based on cadmium(II) ions quantification were 0.1 μg/mL or 10 μg/mL viral protein at HMDE or GCE, respectively. Viral protein detection was directly determined using differential pulse voltammetry Brdicka reaction. The limit detection (3 S/N) of viral protein was estimated as 0.1 μg/mL. Streptavidin-modified paramagnetic particles were mixed with biotinylated selective glycan to modify their surfaces. Under optimized conditions (250 μg/mL of glycan, 30-min long interaction with viral protein, 25°C and 400 rpm), the viral protein labeled with quantum dots was selectively isolated and its cadmium(II) content was determined. Cadmium was present in detectable amounts of 10 ng per mg of protein. Using this method, submicrogram concentrations of viral proteins can be identified. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Spectrofluorimetric determination of cefixime using terbium-danofloxacin probe

    PubMed Central

    Manzoori, Jamshid L.; Amjadi, Mohammad; Soltani, Naser; Jouyban, Abolghasem

    2014-01-01

    Objective(s): Cefixime (Cfx), is a semi-synthetic third-generation oral cephalosporin antibiotic that is prescribed for the treatment of susceptible infections. There are some procedures for the determination of Cfx in pharmaceutical formulations and biological samples. Herein a spectrofluorimetric method was proposed for Cfx determination based on the fluorescence quenching of terbium-danofloxacin (Tb3+-Dano) in the presence of Cfx. Materials and Methods: Cfx was detected based on fluorescence quenching of terbium-danofloxacin (Tb3+-Dano) in the presence of Cfx with maximum excitation and emission wavelengths at 347 nm and 545 nm, respectively. The quenched fluorescence intensity of Tb3+- Dano system is proportional to the concentration of Cfx. The optimum conditions for the determination of Cfx were studied. Results: The maximum response was achieved under optimum conditions of [Tris buffer]= 0.008 mol/l (pH 6.5), [Tb3+]=1×10-4 mol/l and [Dano]=1×10-4 mol/l. The developed method was evaluated in terms of accuracy, precision and limit of detection. The linear concentration ranges for quantification of Cfx were 8.8×10-8-8.8×10-7 mol/l and 1.1×10-7-8.8×10-7 mol/l in standard and human serum samples with the detection limits (S/N=3) of 2.8×10-8 mol/l and 3.9×10-8 mol/l, respectively. The Cfx was determined in pharmaceutical tablets and spiked serum samples and the results were satisfactory. Conclusion: This method is simple, practical and relatively interference-free for determination of Cfx in pharmaceutical tablets and serum samples. PMID:24904718

  1. Empirically Optimized Flow Cytometric Immunoassay Validates Ambient Analyte Theory

    PubMed Central

    Parpia, Zaheer A.; Kelso, David M.

    2010-01-01

    Ekins’ ambient analyte theory predicts, counter intuitively, that an immunoassay’s limit of detection can be improved by reducing the amount of capture antibody. In addition, it also anticipates that results should be insensitive to the volume of sample as well as the amount of capture antibody added. The objective of this study is to empirically validate all of the performance characteristics predicted by Ekins’ theory. Flow cytometric analysis was used to detect binding between a fluorescent ligand and capture microparticles since it can directly measure fractional occupancy, the primary response variable in ambient analyte theory. After experimentally determining ambient analyte conditions, comparisons were carried out between ambient and non-ambient assays in terms of their signal strengths, limits of detection, and their sensitivity to variations in reaction volume and number of particles. The critical number of binding sites required for an assay to be in the ambient analyte region was estimated to be 0.1VKd. As predicted, such assays exhibited superior signal/noise levels and limits of detection; and were not affected by variations in sample volume and number of binding sites. When the signal detected measures fractional occupancy, ambient analyte theory is an excellent guide to developing assays with superior performance characteristics. PMID:20152793

  2. Simultaneous determination of celecoxib, hydroxycelecoxib, and carboxycelecoxib in human plasma using gradient reversed-phase liquid chromatography with ultraviolet absorbance detection.

    PubMed

    Störmer, Elke; Bauer, Steffen; Kirchheiner, Julia; Brockmöller, Jürgen; Roots, Ivar

    2003-01-05

    A new HPLC method for the simultaneous determination of celecoxib, carboxycelecoxib and hydroxycelecoxib in human plasma samples has been developed. Following a solid-phase extraction procedure, the samples were separated by gradient reversed-phase HLPC (C(18)) and quantified using UV detection at 254 nm. The method was linear over the concentration range 10-500 ng/ml. The intra-assay variability for the three analytes ranged from 4.0 to 12.6% and the inter-assay variability from 4.9 to 14.2%. The achieved limits of quantitation (LOQ) of 10 ng/ml for each analyte allowed the determination of the pharmacokinetic parameters of the analytes after administration of 100 mg celecoxib.

  3. SAMPLING AND ANALYSIS OF MERCURY IN CRUDE OIL

    EPA Science Inventory

    Sampling and analytical procedures used to determine total mercury content in crude oils were examined. Three analytical methods were compared with respect to accuracy, precision and detection limit. The combustion method and a commercial extraction method were found adequate to...

  4. Label-free detection of specific DNA sequence-telomere using unmodified gold nanoparticles as colorimetric probes

    NASA Astrophysics Data System (ADS)

    Qi, Yingying; Li, Li; Li, Baoxin

    2009-09-01

    A simple and sensitive label-free colorimetric detection of telomere DNA has been developed. It was based on the color change of gold nanoparticles (AuNPs) due to DNA hybridization. UV-vis spectra and transmission electron microscopy (TEM) were used to investigate the change of AuNPs. Under the optimized conditions, the linear range for determination of telomere DNA was 5.7 × 10 -13 to 4.5 × 10 -6 mol/L. The detection limit (3 σ) of this method has decreased to pico-molar level.

  5. Detection of Scopolamine Hydrobromide via Surface-enhanced Raman Spectroscopy.

    PubMed

    Bao, Lin; Sha, Xuan-Yu; Zhao, Hang; Han, Si-Qin-Gao-Wa; Hasi, Wu-Li-Ji

    2017-01-01

    Surface-enhanced Raman spectroscopy (SERS) was used to measure scopolamine hydrobromide. First, the Raman characteristic peaks of scopolamine hydrobromide were assigned, and the characteristic peaks were determined. The optimal aggregation agent was potassium iodide based on a comparative experimental study. Finally, the SERS spectrum of scopolamine hydrobromide was detected in aqueous solution, and the semi-quantitative analysis and the recovery rate were determined via a linear fitting. The detection limit of scopolamine hydrobromide in aqueous solution was 0.5 μg/mL. From 0 - 10 μg/mL, the curve of the intensity of the Raman characteristic peak of scopolamine hydrobromide at 1002 cm -1 is y = 4017.76 + 642.47x. The correlation coefficient was R 2 = 0.983, the recovery was 98.5 - 109.7%, and the relative standard deviation (RSD) was about 5.5%. This method is fast, accurate, non-destructive and simple for the detection of scopolamine hydrobromide.

  6. The fabrication of magnetic particle-based chemiluminescence immunoassay for human epididymis protein-4 detection in ovarian cancer.

    PubMed

    Fu, Xiaoling; Liu, Yangyang; Qiu, Ruiyun; Foda, Mohamed F; Zhang, Yong; Wang, Tao; Li, Jinshan

    2018-03-01

    The magnetic particles have a significant influence on the immunoassay detection and cancer therapy. Herein, the chemiluminescence immunoassay combined with the magnetic particles (MPCLIA) was presented for the clinical determination and analysis of human epididymis protein 4 (HE4) in the human serum. Under the optimized experiment conditions, the secure MPCLIA method can detect HE4 in the broader range of 0-1000 pmol/L, with a lower detection limit of 1.35 pmol/L. The satisfactory recovery rate of the method in the serum ranged from 83.62% to 105.10%, which was well within the requirement of clinical analysis. Moreover, the results showed the good correlation with enzyme-linked immunosorbent assay (ELISA), with the correlation coefficient of 0.9589. This proposed method has been successfully applied to the clinical determination of HE4 in the human serum.

  7. Thermal detection thresholds in 5-year-old preterm born children; IQ does matter.

    PubMed

    de Graaf, Joke; Valkenburg, Abraham J; Tibboel, Dick; van Dijk, Monique

    2012-07-01

    Experiencing pain at newborn age may have consequences on one's somatosensory perception later in life. Children's perception for cold and warm stimuli may be determined with the Thermal Sensory Analyzer (TSA) device by two different methods. This pilot study in 5-year-old children born preterm aimed at establishing whether the TSA method of limits, which is dependent of reaction time, and the method of levels, which is independent of reaction time, would yield different cold and warm detection thresholds. The second aim was to establish possible associations between intellectual ability and the detection thresholds obtained with either method. A convenience sample was drawn from the participants in an ongoing 5-year follow-up study of a randomized controlled trial on effects of morphine during mechanical ventilation. Thresholds were assessed using both methods and statistically compared. Possible associations between the child's intelligence quotient (IQ) and threshold levels were analyzed. The method of levels yielded more sensitive thresholds than did the method of limits, i.e. mean (SD) cold detection thresholds: 30.3 (1.4) versus 28.4 (1.7) (Cohen'sd=1.2, P=0.001) and warm detection thresholds; 33.9 (1.9) versus 35.6 (2.1) (Cohen's d=0.8, P=0.04). IQ was statistically significantly associated only with the detection thresholds obtained with the method of limits (cold: r=0.64, warm: r=-0.52). The TSA method of levels, is to be preferred over the method of limits in 5-year-old preterm born children, as it establishes more sensitive detection thresholds and is independent of IQ. Copyright © 2011 Elsevier Ltd. All rights reserved.

  8. [Quantitative determination of biogenic amine from Biomphalaria glabrata nervous system by UPLC MS/MS].

    PubMed

    Tao, Huang; Yun-Hai, Guo; He-Xiang, Liu; Yi, Zhang

    2018-04-19

    To establish a method for the quantitative determination of serotonin and dopamine in the nervous system of Biomphalaria glabrata by using ultra high performance liquid chromatography-tandem quadrupole mass spectrometry (UPLC MS/MS) . The B. glabrata nervous system was broken in the pure methanol solution after obtaining it by dissecting with microscope. Then, the supernatant containing the target substance after twice high speed centrifugation was got. The extraction was separated on an ACQUITY UPLC BEH Amide column with Waters TQ-XS series mass spectrometry detector, with ESI source and positive electrospray ionization mode when the machine testing. The detection limit of serotonin was 0.03 ng/ml and the limit of quantification was 0.1 ng/ml. The detection limit of dopamine was 0.05 ng/ml and the limit of quantification was 0.15 ng/ml. The recoveries of serotonin ranged from 90.68% to 94.72% over the range of 1 to 40 ng/ml. The recoveries of dopamine ranged from 91.68% to 96.12% over the range of 1.0 ng/ml to 40 ng/ml. The established UPLC MS/MS method is simple, stable and reproducible. It can be used for the quantitative analysis of serotonin and dopamine in the nervous system of B. glabrata snails.

  9. Analysis of penicillin G in milk by liquid chromatography.

    PubMed

    Boison, J O; Keng, L J; MacNeil, J D

    1994-01-01

    A liquid chromatographic (LC) method that was previously developed for penicillin G residues in animal tissues has been adapted to milk and milk products. After protein precipitation with sodium tungstate, samples are applied to a C18 solid-phase extraction cartridge, from which penicillin is eluted, derivatized with 1,2,4-triazole-mercuric chloride solution, and analyzed by isocratic liquid chromatography (LC) on a C18 column with UV detection at 325 nm. Quantitation is done with reference to penicillin V as an internal standard. Penicillin G recoveries were determined to be > 70% on standards fortified at 3-60 ppb. Accuracy approached 100% using the penicillin V internal standard. The detection limit for penicillin G residues was 3 ppb in fluid milk. Samples may be confirmed by thermospray/LC at concentrations approaching the detection limit of the UV method.

  10. Detection Limit of Smectite by Chemin IV Laboratory Instrument: Preliminary Implications for Chemin on the Mars Science Laboratory Mission

    NASA Technical Reports Server (NTRS)

    Archilles, Cherie; Ming, D. W.; Morris, R. V.; Blake, D. F.

    2011-01-01

    The CheMin instrument on the Mars Science Laboratory (MSL) is an miniature X-ray diffraction (XRD) and X-ray fluorescence (XRF) instrument capable of detecting the mineralogical and elemental compositions of rocks, outcrops and soils on the surface of Mars. CheMin uses a microfocus-source Co X-ray tube, a transmission sample cell, and an energy-discriminating X-ray sensitive CCD to produce simultaneous 2-D XRD patterns and energy-dispersive X-ray histograms from powdered samples. CRISM and OMEGA have identified the presence of phyllosilicates at several locations on Mars including the four candidate MSL landing sites. The objective of this study was to conduct preliminary studies to determine the CheMin detection limit of smectite in a smectite/olivine mixed mineral system.

  11. Proteomic Approaches in Biomarker Discovery: New Perspectives in Cancer Diagnostics

    PubMed Central

    Kocevar, Nina; Komel, Radovan

    2014-01-01

    Despite remarkable progress in proteomic methods, including improved detection limits and sensitivity, these methods have not yet been established in routine clinical practice. The main limitations, which prevent their integration into clinics, are high cost of equipment, the need for highly trained personnel, and last, but not least, the establishment of reliable and accurate protein biomarkers or panels of protein biomarkers for detection of neoplasms. Furthermore, the complexity and heterogeneity of most solid tumours present obstacles in the discovery of specific protein signatures, which could be used for early detection of cancers, for prediction of disease outcome, and for determining the response to specific therapies. However, cancer proteome, as the end-point of pathological processes that underlie cancer development and progression, could represent an important source for the discovery of new biomarkers and molecular targets for tailored therapies. PMID:24550697

  12. A simple high performance liquid chromatography method for analyzing paraquat in soil solution samples.

    PubMed

    Ouyang, Ying; Mansell, Robert S; Nkedi-Kizza, Peter

    2004-01-01

    A high performance liquid chromatography (HPLC) method with UV detection was developed to analyze paraquat (1,1'-dimethyl-4,4'-dipyridinium dichloride) herbicide content in soil solution samples. The analytical method was compared with the liquid scintillation counting (LSC) method using 14C-paraquat. Agreement obtained between the two methods was reasonable. However, the detection limit for paraquat analysis was 0.5 mg L(-1) by the HPLC method and 0.05 mg L(-1) by the LSC method. The LSC method was, therefore, 10 times more precise than the HPLC method for solution concentrations less than 1 mg L(-1). In spite of the high detection limit, the UC (nonradioactive) HPLC method provides an inexpensive and environmentally safe means for determining paraquat concentration in soil solution compared with the 14C-LSC method.

  13. A multi-commuted flow injection system with a multi-channel propulsion unit placed before detection: Spectrophotometric determination of ammonium.

    PubMed

    Oliveira, Sara M; Lopes, Teresa I M S; Tóth, Ildikó V; Rangel, António O S S

    2007-09-26

    A flow system with a multi-channel peristaltic pump placed before the solenoid valves is proposed to overcome some limitations attributed to multi-commuted flow injection systems: the negative pressure can lead to the formation of unwanted air bubbles and limits the use of devices for separation processes (gas diffusion, dialysis or ion-exchange). The proposed approach was applied to the colorimetric determination of ammonium nitrogen. In alkaline medium, ammonium is converted into ammonia, which diffuses over the membrane, causing a pH change and subsequently a colour change in the acceptor stream (bromothymol blue solution). The system allowed the re-circulation of the acceptor solution and was applied to ammonium determination in surface and tap water, providing relative standard deviations lower than 1.5%. A stopped flow approach in the acceptor stream was adopted to attain a low quantification limit (42 microgL(-1)) and a linear dynamic range of 50-1000 microgL(-1) with a determination rate of 20 h(-1).

  14. Companions in Color: High-Resolution Imaging of Kepler’s Sub-Neptune Host Stars

    NASA Astrophysics Data System (ADS)

    Ware, Austin; Wolfgang, Angie; Kannan, Deepti

    2018-01-01

    A current problem in astronomy is determining how sub-Neptune-sized exoplanets form in planetary systems. These kinds of planets, which fall between 1 and 4 times the size of Earth, were discovered in abundance by the Kepler Mission and were typically found with relatively short orbital periods. The combination of their size and orbital period make them unusual in relation to the Solar System, leading to the question of how these exoplanets form and evolve. One possibility is that they have been influenced by distant stellar companions. To help assess the influence of these objects on the present-day, observed properties of exoplanets, we conduct a NIR search for visual stellar companions to the stars around which the Kepler Mission discovered planets. We use high-resolution images obtained with the adaptive optics systems at the Lick Observatory Shane-3m telescope to find these companion stars. Importantly, we also determine the effective brightness and distance from the planet-hosting star at which it is possible to detect these companions. Out of the 200 KOIs in our sample, 42 KOIs (21%) have visual companions within 3”, and 90 (46%) have them within 6”. These findings are consistent with recent high-resolution imaging from Furlan et al. 2017 that found at least one visual companion within 4” for 31% of sampled KOIs (37% within 4" for our sample). Our results are also complementary to Furlan et al. 2017, with only 17 visual companions commonly detected in the same filter. As for detection limits, our preliminary results indicate that we can detect companion stars < 3-5 magnitudes fainter than the planet-hosting star at a separation of ~ 1”. These detection limits will enable us to determine the probability that possible companion stars could be hidden within the noise around the planet-hosting star, an important step in determining the frequency with which these short-period, sub-Neptune-sized planets occur within binary star systems.

  15. Detection limits of Legionella pneumophila in environmental samples after co-culture with Acanthamoeba polyphaga

    PubMed Central

    2013-01-01

    Background The efficiency of recovery and the detection limit of Legionella after co-culture with Acanthamoeba polyphaga are not known and so far no investigations have been carried out to determine the efficiency of the recovery of Legionella spp. by co-culture and compare it with that of conventional culturing methods. This study aimed to assess the detection limits of co-culture compared to culture for Legionella pneumophila in compost and air samples. Compost and air samples were spiked with known concentrations of L. pneumophila. Direct culturing and co-culture with amoebae were used in parallel to isolate L. pneumophila and recovery standard curves for both methods were produced for each sample. Results The co-culture proved to be more sensitive than the reference method, detecting 102-103 L. pneumophila cells in 1 g of spiked compost or 1 m3 of spiked air, as compared to 105-106 cells in 1 g of spiked compost and 1 m3 of spiked air. Conclusions Co-culture with amoebae is a useful, sensitive and reliable technique to enrich L. pneumophila in environmental samples that contain only low amounts of bacterial cells. PMID:23442526

  16. Kinetic Modeling of Accelerated Stability Testing Enabled by Second Harmonic Generation Microscopy.

    PubMed

    Song, Zhengtian; Sarkar, Sreya; Vogt, Andrew D; Danzer, Gerald D; Smith, Casey J; Gualtieri, Ellen J; Simpson, Garth J

    2018-04-03

    The low limits of detection afforded by second harmonic generation (SHG) microscopy coupled with image analysis algorithms enabled quantitative modeling of the temperature-dependent crystallization of active pharmaceutical ingredients (APIs) within amorphous solid dispersions (ASDs). ASDs, in which an API is maintained in an amorphous state within a polymer matrix, are finding increasing use to address solubility limitations of small-molecule APIs. Extensive stability testing is typically performed for ASD characterization, the time frame for which is often dictated by the earliest detectable onset of crystal formation. Here a study of accelerated stability testing on ritonavir, a human immunodeficiency virus (HIV) protease inhibitor, has been conducted. Under the condition for accelerated stability testing at 50 °C/75%RH and 40 °C/75%RH, ritonavir crystallization kinetics from amorphous solid dispersions were monitored by SHG microscopy. SHG microscopy coupled by image analysis yielded limits of detection for ritonavir crystals as low as 10 ppm, which is about 2 orders of magnitude lower than other methods currently available for crystallinity detection in ASDs. The four decade dynamic range of SHG microscopy enabled quantitative modeling with an established (JMAK) kinetic model. From the SHG images, nucleation and crystal growth rates were independently determined.

  17. GFAAS determination of selenium in infant formulas using a microwave digestion method.

    PubMed

    Alegria, A; Barbera, R; Farré, R; Moreno, A

    1994-01-01

    A method for determining the selenium content of infant formulas is proposed. It includes wet digestion with nitric acid and hydrogen peroxide in medium pressure teflon bombs in a microwave oven and determination by graphite furnace atomic absorption spectrometry (GFAAS). The absence of interferences is checked. Values obtained for the limit of detection (19.4 ng/g), precision (RSD = 2.2%) and accuracy by analysis of a reference material show that the method is reliable.

  18. Low Cost Solar Array Project: Composition Measurements by Analytical Photo Catalysis

    NASA Technical Reports Server (NTRS)

    Sutton, D. G.; Galvan, L.; Melzer, J.; Heidner, R. F., III

    1979-01-01

    The applicability of the photon catalysis technique for effecting composition analysis of silicon samples is discussed. A detector for the impurities Al, Cr, Fe, Mn, Ti, V, Mo and Zr is evaluated. During the first reporting period Al, Cr, Fe, and Mn were detected with the photon catalysis method. The best fluorescence lines to monitor and determine initial sensitivities to each of these elements by atomic absorption calibration were established. In the course of these tests vapor pressure curves for these four pure substances were also mapped. Ti and Si were detected. The best lines to monitor were catalogued and vapor pressure curves were determined. Attempts to detect vanadium were unsuccessful due to the refractory nature of this element and the limited temperature range of the evaporator.

  19. [Determination of phenazine-1-carboxylic acid in anti-fungal agent M18 by high performance liquid chromatography].

    PubMed

    Zhu, D H; Zhu, X D; Xu, Y Q

    2001-11-01

    A reversed-phase HPLC method for the determination of phenazine-1-carboxylic acid (PCA) in antifungal agent M18 is established. The mobile phase was a mixture of MeOH-5 mmol/L phosphate buffer (pH 5.0) (60:40, volume ratio). The flow rate was 1.0 mL/min, and the detection wavelength was 248 nm. The linear range and detectable limit were 50 mg/L-500 mg/L and 30 mg/L respectively. The recovery was 97.53% and RSD was 1.5%. The method of PCA extraction and detection has proven to be much faster, simpler, more sensitive, accurate and reproducible than those reported already. The assay results can be used as a very important criterion for large-scale production.

  20. Capillary electrophoresis of chitooligosaccharides in acidic solution: simple determination using a quaternary-ammonium-modified column and indirect photometric detection with crystal violet.

    PubMed

    Hattori, Toshiaki; Anraku, Nobuhiro; Kato, Ryo

    2010-02-01

    Five chitosan oligosaccharides were separated in acidic aqueous solution by capillary electrophoresis (CE) with indirect photometric detection using a positively coated capillary. Electrophoretic mobility of the chitooligosaccharides (COSs) depended on the number of monomer units in acidic aqueous solution, similar to other polyelectrolyte oligomers. The separation was developed in nitric acid aqueous solution at pH 3.0 with 1 mM Crystal Violet, using a capillary positively coated with N-trimethoxypropyl-N,N,N-trimethylammonium chloride. The limit of the detection for chitooligosaccharides with two to six saccharide chains was less than 5 microM. CE determination of an enzymatically hydrolyzed COS agreed with results from HPLC. 2009 Elsevier B.V. All rights reserved.

  1. Application of a SERS-based lateral flow immunoassay strip for the rapid and sensitive detection of staphylococcal enterotoxin B

    NASA Astrophysics Data System (ADS)

    Hwang, Joonki; Lee, Sangyeop; Choo, Jaebum

    2016-06-01

    A novel surface-enhanced Raman scattering (SERS)-based lateral flow immunoassay (LFA) biosensor was developed to resolve problems associated with conventional LFA strips (e.g., limits in quantitative analysis and low sensitivity). In our SERS-based biosensor, Raman reporter-labeled hollow gold nanospheres (HGNs) were used as SERS detection probes instead of gold nanoparticles. With the proposed SERS-based LFA strip, the presence of a target antigen can be identified through a colour change in the test zone. Furthermore, highly sensitive quantitative evaluation is possible by measuring SERS signals from the test zone. To verify the feasibility of the SERS-based LFA strip platform, an immunoassay of staphylococcal enterotoxin B (SEB) was performed as a model reaction. The limit of detection (LOD) for SEB, as determined with the SERS-based LFA strip, was estimated to be 0.001 ng mL-1. This value is approximately three orders of magnitude more sensitive than that achieved with the corresponding ELISA-based method. The proposed SERS-based LFA strip sensor shows significant potential for the rapid and sensitive detection of target markers in a simplified manner.A novel surface-enhanced Raman scattering (SERS)-based lateral flow immunoassay (LFA) biosensor was developed to resolve problems associated with conventional LFA strips (e.g., limits in quantitative analysis and low sensitivity). In our SERS-based biosensor, Raman reporter-labeled hollow gold nanospheres (HGNs) were used as SERS detection probes instead of gold nanoparticles. With the proposed SERS-based LFA strip, the presence of a target antigen can be identified through a colour change in the test zone. Furthermore, highly sensitive quantitative evaluation is possible by measuring SERS signals from the test zone. To verify the feasibility of the SERS-based LFA strip platform, an immunoassay of staphylococcal enterotoxin B (SEB) was performed as a model reaction. The limit of detection (LOD) for SEB, as determined with the SERS-based LFA strip, was estimated to be 0.001 ng mL-1. This value is approximately three orders of magnitude more sensitive than that achieved with the corresponding ELISA-based method. The proposed SERS-based LFA strip sensor shows significant potential for the rapid and sensitive detection of target markers in a simplified manner. Electronic supplementary information (ESI) available. See DOI: 10.1039/c5nr07243c

  2. Detection of trace amount of arsenic in groundwater by laser-induced breakdown spectroscopy and adsorption

    NASA Astrophysics Data System (ADS)

    Haider, A. F. M. Y.; Hedayet Ullah, M.; Khan, Z. H.; Kabir, Firoza; Abedin, K. M.

    2014-03-01

    LIBS technique coupled with adsorption has been applied for the efficient detection of arsenic in liquid. Several adsorbents like tea leaves, bamboo slice, charcoal and zinc oxide have been used to enable sensitive detection of arsenic presence in water using LIBS. Among these, zinc oxide and charcoal show the better results. The detection limits for arsenic in water were 1 ppm and 8 ppm, respectively, when ZnO and charcoal were used as adsorbents of arsenic. To date, the determination of 1 ppm of As in water is the lowest concentration of detected arsenic in water by the LIBS technique. The detection limit of As was lowered to even less than 100 ppb by a combination of LIBS technique, adsorption by ZnO and concentration enhancement technique. Using the combination of these three techniques the ultimate concentration of arsenic was found to be 0.083 ppm (83 ppb) for arsenic polluted water collected from a tube-well of Farajikandi union (longitude 90.64°, latitude 23.338° north) of Matlab Upozila of Chandpur district in Bangladesh. This result compares fairly well with the finding of arsenic concentration of 0.078 ppm in the sample by the AAS technique at the Bangladesh Council of Scientific and Industrial Research (BCSIR) lab. Such a low detection limit (1 ppm) of trace elements in liquid matrix has significantly enhanced the scope of LIBS as an analytical tool.

  3. A new rhodamine-based colorimetric chemosensor for naked-eye detection of Cu2 + in aqueous solution

    NASA Astrophysics Data System (ADS)

    Hu, Yang; Zhang, Jing; Lv, Yuan-Zheng; Huang, Xiao-Huan; Hu, Sheng-li

    2016-03-01

    A new colorimetric probe 1 based on rhodamine B lactam was developed for naked-eye detection of Cu2 +. The optical feature of 1 for Cu2 + was investigated by UV-vis absorption spectroscopy. Upon the addition of Cu2 +, the 1 displayed a distinct color change from colorless to pink, which can be directly detected by the naked eye. The stoichiometry of 1 to Cu2 + complex was found to be 1:1 and the naked-eye detection limit was determined as low as 2 μM. The results suggest that the probe 1 may provide a convenient method for visual detection of Cu2 + with high sensitivity.

  4. Improvement of direct determination of trace nickel in environmental samples by diffuse reflection spectroscopy using chromaticity characteristics.

    PubMed

    Ershova, N I; Ivanov, V M

    2000-05-01

    Cellulose and chromaton-N-super as solid supports for direct determination of the immobilized nickel complexes with dimethylglyoxime and benzyldioxime by diffuse reflection spectroscopy were compared. The advantage of chromaton-N-super with use of benzyldioxime is shown. Detection limit is 0.02 microg/mL. The proposed method was applied for the analysis of soil.

  5. Detection of Posaconazole by Surface-Assisted Laser Desorption/Ionization Mass Spectrometry with Dispersive Liquid-Liquid Microextraction

    NASA Astrophysics Data System (ADS)

    Lin, Sheng-Yu; Chen, Pin-Shiuan; Chang, Sarah Y.

    2015-03-01

    A simple, rapid, and sensitive method for the detection of posaconazole using dispersive liquid-liquid microextraction (DLLME) coupled to surface-assisted laser desorption/ionization mass spectrometric detection (SALDI/MS) was developed. After the DLLME, posaconazole was detected using SALDI/MS with colloidal gold and α-cyano-4-hydroxycinnamic acid (CHCA) as the co-matrix. Under optimal extraction and detection conditions, the calibration curve, which ranged from 1.0 to 100.0 nM for posaconazole, was observed to be linear. The limit of detection (LOD) at a signal-to-noise ratio of 3 was 0.3 nM for posaconazole. This novel method was successfully applied to the determination of posaconazole in human urine samples.

  6. Direct determination of arsenic in steel by glow discharge optical emission spectrometry with argon-helium mixed gas.

    PubMed

    Wagatsuma, Kazuaki

    2003-02-01

    In glow discharge optical emission spectrometry, an argon-helium mixed gas plasma was investigated to improve the detection sensitivity of arsenic in steel samples. The emission line of arsenic was enhanced and the background intensity was simultaneously reduced when an Ar-He plasma was employed instead of an Ar plasma, which is effective for the sensitive determination of arsenic. The detection limits were calculated to be 0.009 mass% for a 700-V Ar plasma, 0.004 mass% for a 700-V Ar-He plasma, and 0.001 mass% for a 900-V Ar-He plasma.

  7. Spectrophotometric determination of ketoprofen and its application in pharmaceutical analysis.

    PubMed

    Kormosh, Zholt; Hunka, Iryna; Basel, Yaroslav

    2009-01-01

    A new simple rapid and sensitive spectrophotometric method has been developed for the determination of ketoprofen in pharmaceutical preparations. The method is based on the reaction of ketoprofen with an analytical reagent--Astra Phloxin FF--at pH 8.0-10.8 and followed by the extraction of formed ion associate in toluene with spectrophotometric detection (it has an absorption maximum at 563 nm, epsilon = 7.6 x 10(4) L x mol(-1) x cm(-1)). The calibration plot was linear from 0.8-16.0 microg x mL(-1) of ketoprofen, and the detection limit was 0.037 microg x mL(-1).

  8. Derivatization in gas chromatographic determination of phenol and aniline traces in aqueous media

    NASA Astrophysics Data System (ADS)

    Gruzdev, I. V.; Zenkevich, I. G.; Kondratenok, B. M.

    2015-06-01

    Substituted anilines and phenols are the most common hydrophilic organic environmental toxicants. The principles of gas chromatographic determination of trace amounts of these compounds in aqueous media at concentrations <=0.1 μg litre-1 based on synthesis of their derivatives (derivatization) directly in the aqueous phase are considered. Conversion of relatively hydrophilic analytes into more hydrophobic derivatives makes it possible to achieve such low detection limits and optimize the protocols of extractive preconcentration and selective chromatographic detection. Among the known reactions, this condition is best met by electrophilic halogenation of compounds at the aromatic moiety. The bibliography includes 177 references.

  9. [Amperometric biosensor for ethanol analysis in wines and grape must during wine fermentation].

    PubMed

    Shkotova, L V; Slast'ia, E A; Zhyliakova, T A; Soldatkin, O P; Schuhmann, W; Dziadevych, S V

    2005-01-01

    The amperometric biosensor for ethanol determination based on alcohol oxidase immobilised by the method of electrochemical polymerization has been developed. The industrial screen-printed platinum electrodes were used as transducers for creation of amperometric alcohol biosensor. Optimal conditions for electrochemical deposition of an active membrane with alcohol oxidase has been determined. Biosensors are characterised by good reproducibility and operational stability with minimal detection limit of ethanol 8 x 10(-5) M. The good correlation of results for ethanol detection in wine and during wine fermentation by using the developed amperometric biosensor with the data obtained by the standard methods was shown (r = 0.995).

  10. Molecular imprinting-chemiluminescence determination of trimethoprim using trimethoprim-imprinted polymer as recognition material.

    PubMed

    He, Yunhua; Lu, Jiuru; Liu, Mei; Du, Jianxiu

    2005-07-01

    A new molecular imprinting-chemiluminescence method for the determination of trimethoprim was developed, in which trimethoprim-imprinted polymer was used as the molecular recognition material and the CL reaction of trimethoprim with potassium permanganate in acidic medium was used as the detection system. The CL intensity responds linearly to the concentration of trimethoprim within the 5.0 x 10(-8)-5.0 x 10(-6) g mL(-1) range (r= 0.9983) with a detection limit of 2 x 10(-8) g mL(-1). The relative standard deviation for the determination of 1.0 x 10(-7) g mL(-1) trimethoprim solutions is 4.8% (n= 9). The method has been applied to the determination of trimethoprim in pharmaceutical preparations and body fluids, and satisfactory results were obtained.

  11. Influence of pre-treatment process on matrix effect for the determination of musk fragrances in fish and mussel.

    PubMed

    Vallecillos, Laura; Pocurull, Eva; Borrull, Francesc

    2015-03-01

    Musk compounds are widely used as fragrances in personal care products. On account of their widespread use and their low biodegradation, they can be found in environmental samples. In our study two extraction methodologies were compared and different clean-up strategies were also studied in order to develop a reliable analytical method, with minimum matrix effect and good detection limits, to determine synthetic musk fragrances- six polycyclic musks, three nitro musks and the degradation product of one polycyclic musk- in fish and mussel samples. The first extraction technique involves a QuEChERS extraction, a consolidate extraction methodology in the field of food analysis of growing interest over recent years, followed by a dispersive solid-phase extraction (dSPE) as clean-up strategy. The second extraction technique consists of a conventional pressurised liquid extraction (PLE) with dichloromethane and an in-cell clean-up to decrease the matrix effect and remove the undesired components(⁎)present in PLE extracts. Large volume injection (LVI) followed by gas chromatography-ion trap-tandem mass spectrometry (GC-IT-MS/MS) was chosen as the separation and detection technique. Validation parameters, such as method detection limits and method quantification limits were found at ng g(-1) levels for both fish and mussel matrices. Good levels of intra-day and inter-day repeatabilities were obtained analysing fish and mussel samples spiked at 50 ng g(-1) (d.w.) (n=5, RSDs<17%). The developed PLE/GC-IT-MS/MS method was successfully applied to determine the target musk fragrances present in fish and mussel samples from the local market in Tarragona and fish samples from the Ebro River. The results showed the presence of galaxolide (2.97-18.04 ng g(-1) (d.w.)) and tonalide (1.17-8.42 ng g(-1) (d.w.)) in all the samples analysed, while the remaining polycyclic musks such as cashmeran, celestolide and phantolide, were only detected in some of the fish samples analysed. None of the samples analysed contained detectable traces of the nitro musks studied. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. Determination of ammonium on an integrated microchip with LED-induced fluorescence detection.

    PubMed

    Xue, Shuhua; Uchiyama, Katsumi; Li, Hai-Fang

    2012-01-01

    A simply fabricated microfluidic device integrated with a fluorescence detection system has been developed for on-line determination of ammonium in aqueous samples. A 365-nm light-emitting diode (LED) as an excitation source and a minor band pass filter were mounted into a polydimethylsiloxane (PDMS)-based microchip for the purpose of miniaturization of the entire analytical system. The ammonium sample reacted with o-phthaldialdehyde (OPA) on-chip with sodium sulfite as reducing reagent to produce a fluorescent isoindole derivative, which can emit fluorescence signal at about 425 nm when excited at 365 nm. Effects of pH, flow rate of solutions, concentrations of OPA-reagent, phosphate and sulfite salt were investigated. The calibration curve of ammonium in the range of 0.018-1.8 microg/mL showed a good linear relationship with R2 = 0.9985, and the detection limit was (S/N = 3) 3.6 x 10(-4) microg/mL. The relative standard deviation was 2.8% (n = 11) by calculating at 0.18 microg/mL ammonium for repeated detection. The system was applied to determine the ammonium concentration in rain and river waters, even extent to other analytes fluorescence detection by the presented device.

  13. Vapor permeation-stepwise injection simultaneous determination of methanol and ethanol in biodiesel with voltammetric detection.

    PubMed

    Shishov, Andrey; Penkova, Anastasia; Zabrodin, Andrey; Nikolaev, Konstantin; Dmitrenko, Maria; Ermakov, Sergey; Bulatov, Andrey

    2016-02-01

    A novel vapor permeation-stepwise injection (VP-SWI) method for the determination of methanol and ethanol in biodiesel samples is discussed. In the current study, stepwise injection analysis was successfully combined with voltammetric detection and vapor permeation. This method is based on the separation of methanol and ethanol from a sample using a vapor permeation module (VPM) with a selective polymer membrane based on poly(phenylene isophtalamide) (PA) containing high amounts of a residual solvent. After the evaporation into the headspace of the VPM, methanol and ethanol were transported, by gas bubbling, through a PA membrane to a mixing chamber equipped with a voltammetric detector. Ethanol was selectively detected at +0.19 V, and both compounds were detected at +1.20 V. Current subtractions (using a correction factor) were used for the selective determination of methanol. A linear range between 0.05 and 0.5% (m/m) was established for each analyte. The limits of detection were estimated at 0.02% (m/m) for ethanol and methanol. The sample throughput was 5 samples h(-1). The method was successfully applied to the analysis of biodiesel samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. PRINCIPLES OF SYNCHROTRON TECHNIQUES, POTENTIAL AND LIMITATIONS

    EPA Science Inventory

    Once environmental contaminants, such as arsenic, chromium, cadmium and lead, are detected, the problem becomes how to deal with them. For the past decade, researchers at the US EPA in Cincinnati have been employing synchrotron speciation methods to determine the exact chemical f...

  15. Simultaneous detection of creatine and creatinine using a sequential injection analysis/biosensor system.

    PubMed

    Stefan-van Staden, Raluca-Ioana; Bokretsion, Rahel Girmai; van Staden, Jacobus F; Aboul-Enein, Hassan Y

    2006-01-01

    Carbon paste based biosensors for the determination of creatine and creatinine have been integrated into a sequential injection system. Applying the multi-enzyme sequence of creatininase (CA), and/or creatinase (CI) and sarcosine oxidase (SO), hydrogen peroxide has been detected amperometrically. The linear concentration ranges are of pmol/L to nmol/L magnitude, with very low limits of detection. The proposed SIA system can be utilized reliably for the on-line simultaneous detection of creatine and creatinine in pharmaceutical products, as well as in serum samples, with a rate of 34 samples per hour and RSD values better than 0.16% (n=10).

  16. Trouble Brewing: Using Observations of Invariant Behavior to Detect Malicious Agency in Distributed Control Systems

    NASA Astrophysics Data System (ADS)

    McEvoy, Thomas Richard; Wolthusen, Stephen D.

    Recent research on intrusion detection in supervisory data acquisition and control (SCADA) and DCS systems has focused on anomaly detection at protocol level based on the well-defined nature of traffic on such networks. Here, we consider attacks which compromise sensors or actuators (including physical manipulation), where intrusion may not be readily apparent as data and computational states can be controlled to give an appearance of normality, and sensor and control systems have limited accuracy. To counter these, we propose to consider indirect relations between sensor readings to detect such attacks through concurrent observations as determined by control laws and constraints.

  17. Investigation of light scattering as a technique for detecting discrete soot particles in a luminous flame

    NASA Technical Reports Server (NTRS)

    1978-01-01

    The practicability of using a classical light-scattering technique, involving comparison of angular scattering intensity patterns with theoretically determined Mie and Rayleight patterns, to detect discrete soot particles (diameter less than 50 nm) in premixed propane/air and propane/oxygen-helium flames is considered. The experimental apparatus employed in this investigation included a laser light source, a flat-flame burner, specially coated optics, a cooled photomultiplier detector, and a lock-in voltmeter readout. Although large, agglomerated soot particles were detected and sized, it was not possible to detect small, discrete particles. The limiting factor appears to be background scattering by the system's optics.

  18. Sensitive and selective determination of methylenedioxylated amphetamines by high-performance liquid chromatography with fluorimetric detection.

    PubMed

    Sadeghipour, F; Veuthey, J L

    1997-11-07

    A rapid, sensitive and selective liquid chromatographic method with fluorimetric detection was developed for the separation and quantification of four methylenedioxylated amphetamines without interference of other drugs of abuse and common substances found in illicit tablets. The method was validated by examining linearity, precision and accuracy as well as detection and quantification limits. Methylenedioxylated amphetamines were quantified in eight tablets from illicit drug seizures and results were quantitatively compared to HPLC-UV analyses. To demonstrate the better sensitivity of the fluorimetric detection, methylenedioxylated amphetamines were analyzed in serum after a liquid-liquid extraction procedure and results were also compared to HPLC-UV analyses.

  19. Determination of homovanillic acid (HVA) in human plasma by HPLC with coulometric detection and a new SPE procedure.

    PubMed

    Saracino, M A; Mandrioli, R; Mercolini, L; Ferranti, A; Zaimovic, A; Leonardi, C; Raggi, M A

    2006-09-11

    A sensitive high-performance liquid chromatographic method has been developed for the determination of homovanillic acid (HVA), the main metabolite of dopamine, in human plasma. Analyses were carried out on a reversed-phase column (C8, 250 mm x 4.6 mm i.d., 5 microm) using a mobile phase composed of 10% methanol and 90% aqueous citrate buffer, containing octanesulfonic acid and EDTA at pH 4.8. Coulometric detection was used, setting the guard cell at +0.100 V, the first analytical cell at -0.200 V and the second analytical cell at +0.500 V. A careful solid-phase extraction procedure, based on strong anion exchange (SAX) cartridges (100 mg, 1 mL), was implemented for the pre-treatment of plasma samples. Extraction yield was satisfactory, being the mean value 98.0%. The calibration curve was linear over the concentration range of 0.2-25.0 ng mL(-1) of homovanillic acid. The limit of quantitation (LOQ) was 0.2 ng mL(-1) and the limit of detection (LOD) was 0.1 ng mL(-1). The method was successfully applied to plasma samples from former alcohol, cocaine and heroin addicts. Results were satisfactory in terms of precision and accuracy. Hence, the method is suitable for the determination of homovanillic acid in human plasma.

  20. Fast and simultaneous determination of 12 polyphenols in apple peel and pulp by using chemometrics-assisted high-performance liquid chromatography with diode array detection.

    PubMed

    Wang, Tong; Wu, Hai-Long; Xie, Li-Xia; Zhu, Li; Liu, Zhi; Sun, Xiao-Dong; Xiao, Rong; Yu, Ru-Qin

    2017-04-01

    In this work, a smart chemometrics-enhanced strategy, high-performance liquid chromatography, and diode array detection coupled with second-order calibration method based on alternating trilinear decomposition algorithm was proposed to simultaneously quantify 12 polyphenols in different kinds of apple peel and pulp samples. The proposed strategy proved to be a powerful tool to solve the problems of coelution, unknown interferences, and chromatographic shifts in the process of high-performance liquid chromatography analysis, making it possible for the determination of 12 polyphenols in complex apple matrices within 10 min under simple conditions of elution. The average recoveries with standard deviations, and figures of merit including sensitivity, selectivity, limit of detection, and limit of quantitation were calculated to validate the accuracy of the proposed method. Compared to the quantitative analysis results from the classic high-performance liquid chromatography method, the statistical and graphical analysis showed that our proposed strategy obtained more reliable results. All results indicated that our proposed method used in the quantitative analysis of apple polyphenols was an accurate, fast, universal, simple, and green one, and it was expected to be developed as an attractive alternative method for simultaneous determination of multitargeted analytes in complex matrices. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Egorov, Oleg; O'Hara, Matthew J.; Grate, Jay W.

    An automated fluidic instrument is described that rapidly determines the total 99Tc content of aged nuclear waste samples, where the matrix is chemically and radiologically complex and the existing speciation of the 99Tc is variable. The monitor links microwave-assisted sample preparation with an automated anion exchange column separation and detection using a flow-through solid scintillator detector. The sample preparation steps acidify the sample, decompose organics, and convert all Tc species to the pertechnetate anion. The column-based anion exchange procedure separates the pertechnetate from the complex sample matrix, so that radiometric detection can provide accurate measurement of 99Tc. We developed amore » preprogrammed spike addition procedure to automatically determine matrix-matched calibration. The overall measurement efficiency that is determined simultaneously provides a self-diagnostic parameter for the radiochemical separation and overall instrument function. Continuous, automated operation was demonstrated over the course of 54 h, which resulted in the analysis of 215 samples plus 54 hly spike-addition samples, with consistent overall measurement efficiency for the operation of the monitor. A sample can be processed and measured automatically in just 12.5 min with a detection limit of 23.5 Bq/mL of 99Tc in low activity waste (0.495 mL sample volume), with better than 10% RSD precision at concentrations above the quantification limit. This rapid automated analysis method was developed to support nuclear waste processing operations planned for the Hanford nuclear site.« less

  2. One-Step Immunochromatography Assay Kit for Detecting Antibodies to Canine Parvovirus

    PubMed Central

    Oh, Jin-Sik; Ha, Gun-Woo; Cho, Young-Shik; Kim, Min-Jae; An, Dong-Jun; Hwang, Kyu-Kye; Lim, Yoon-Kyu; Park, Bong-Kyun; Kang, BoKyu; Song, Dae-Sub

    2006-01-01

    This study was performed to determine the feasibility of using whole serum to detect antibodies to canine parvovirus (CPV) under nonlaboratory conditions and to evaluate the performance characteristics of an immunochromatography assay kit. Precise detection of levels of antibody against CPV in puppies can be used to determine a vaccination schedule, because maternal antibodies frequently result in the failure of protective vaccination, and can also be used to determine the antibody levels of infected puppies. Several methods for the titration of CPV antibodies have been reported, including the hemagglutination inhibition (HI) assay, which is considered the “gold standard.” These methods, however, require intricate and time-consuming procedures. In this study, a total of 386 serum specimens were tested. Compared to the HI assay, the rapid assay had a 97.1% sensitivity and a 76.6% specificity (with a cutoff HI titer of 1:80). This single-step assay could be performed rapidly and easily without special equipment. The kit provides a reliable method for detection of anti-CPV antibody where laboratory support and personnel are limited. PMID:16603622

  3. One-step immunochromatography assay kit for detecting antibodies to canine parvovirus.

    PubMed

    Oh, Jin-Sik; Ha, Gun-Woo; Cho, Young-Shik; Kim, Min-Jae; An, Dong-Jun; Hwang, Kyu-Kye; Lim, Yoon-Kyu; Park, Bong-Kyun; Kang, BoKyu; Song, Dae-Sub

    2006-04-01

    This study was performed to determine the feasibility of using whole serum to detect antibodies to canine parvovirus (CPV) under nonlaboratory conditions and to evaluate the performance characteristics of an immunochromatography assay kit. Precise detection of levels of antibody against CPV in puppies can be used to determine a vaccination schedule, because maternal antibodies frequently result in the failure of protective vaccination, and can also be used to determine the antibody levels of infected puppies. Several methods for the titration of CPV antibodies have been reported, including the hemagglutination inhibition (HI) assay, which is considered the "gold standard." These methods, however, require intricate and time-consuming procedures. In this study, a total of 386 serum specimens were tested. Compared to the HI assay, the rapid assay had a 97.1% sensitivity and a 76.6% specificity (with a cutoff HI titer of 1:80). This single-step assay could be performed rapidly and easily without special equipment. The kit provides a reliable method for detection of anti-CPV antibody where laboratory support and personnel are limited.

  4. Modified surface based on magnetic nanocomposite of dithiooxamide/Fe3O4 as a sorbent for preconcentration and determination of trace amounts of copper

    NASA Astrophysics Data System (ADS)

    Mirabi, Ali; Shokuhi Rad, Ali; Khodadad, Hadiseh

    2015-09-01

    Magnetic nanocomposites surface (MNCS) which has anionic surfactant sodium dodecyl sulfate (SDS) coating and has undergone dithiooxamide treatment as the sorbent could be an easy and useful method to extract and make a pre-concentrated in detecting the copper ions before they are determined via the flame atomic absorption spectrometry (FAAS). The influences of the experimental parameters such as the pH of the sample, the type and concentration of the eluent, dithiooxamide concentration and volume, amount of sorbent and the interactions of ions with respect to the copper ion detection have been studied. The calibration graph was linear in the range of 2-600 ng ml-1 with detection limit of 0.2 ng ml-1. Relative standard deviation (RSD) for 6 replicate measurements was 1.8%. This method of detection has been applied to the determination of Cu ions at levels in real samples such as wheat flour, tomatoes, potatoes, red beans, oat, tap water, river water and sea water with satisfactory results.

  5. Determination of catechins in human urine subsequent to tea ingestion by high-performance liquid chromatography with electrochemical detection.

    PubMed

    Yang, B; Arai, K; Kusu, F

    2000-07-15

    The title determination was conducted by HPLC with electrochemical detection using an ODS column and a mobile phase of acetonitrile: 0.1 M phosphate buffer (pH 2.5) (15:85, v/v). The eight catechins, gallocatechin (GC), epigallocatechin (EGC), catechin (C), epicatechin (EC), epigallocatechin gallate (EGCg), gallocatechin gallate (GCg), epicatechin gallate (ECg), and catechin gallate (Cg), were detected at 0.6 V vs Ag/AgCl. Good linear relationships between current and amount were noted for 0.5-250 pmol of each catechin, with a correlation coefficient of 0.999 in each case. The detection limit for any one was 0.5 pmol (signal to noise ratio, S/N = 3). After the ingestion of 340 ml canned green tea, GC, EGC, C, and EC, mostly in conjugated form, were determined in urine samples. Conjugated catechins were hydrolyzed by enzymes using sulfatase and beta-glucuronidase. The time courses of the above four catechins showed a maxima at 1-3 h after tea ingestion. (+), (-)-EC and (+), (-)-C were present in canned tea.

  6. Simultaneous determination of several antalgic drugs based on their interactions with beta-cyclodextrin by capillary zone electrophoresis.

    PubMed

    Wei, Wei; Yu, Xiaodong; Ju, Huangxin

    2004-03-01

    The binding constants of beta-cyclodextrin (beta-CD) with antalgic drugs such as naproxen, ketoprofen, ibuprofen, acemetacin, and aspirin are determined by affinity capillary electrophoresis. Based on these interactions, a reliable method for the separation and simultaneous determinations of these compounds in the presence of 5.0 mM beta-CD in phosphate buffer solution is presented by capillary zone electrophoresis with UV detection at 214 nm for naproxen and 200 nm for the others. The linear ranges for naproxen, ketoprofen, ibuprofen, acemetacin, aspirin, and caffeine detections are from 2.0 to 800, 2.5 to 1000, 2.5 to 700, 2.5 to 700, 2.0 to 800, and 1.5 to 800 microg/mL, respectively. Their detection limits are 1.0, 0.5, 0.5, 1.5, 1.5, and 1.0 microg/mL at a signal to noise ratio of 3, respectively. This method has been successfully applied to the detections of these drugs in the pharmaceutical formulations (tablets or capsules) and urine samples.

  7. Electrochemical DNA biosensor based on a glassy carbon electrode modified with gold nanoparticles and graphene for sensitive determination of Klebsiella pneumoniae carbapenemase.

    PubMed

    Pan, Hong-zhi; Yu, Hong-wei; Wang, Na; Zhang, Ze; Wan, Guang-cai; Liu, Hao; Guan, Xue; Chang, Dong

    2015-11-20

    We describe the fabrication of a sensitive electrochemical DNA biosensor for determination of Klebsiella pneumoniae carbapenemase (KPC). The highly sensitive and selective electrochemical biosensor for DNA detection was constructed based on a glassy carbon electrode (GCE) modified with gold nanoparticles (Au-NPs) and graphene (Gr). Then Au-NPs/Gr/GCE was characterized by scanning electro microscope (SEM), cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The hybridization detection was measured by diffierential pulse voltammetry (DPV) using methylene blue (MB) as the hybridization indicator. The dynamic range of detection of the sensor for the target DNA sequences was from 1 × 10(-12) to 1 × 10(-7)mol/L, with a detection limit of 2 × 10(-13)mol/L. The DNA biosensor had excellent specificity for distinguishing complementary DNA sequence in the presence of non-complementary and mismatched DNA sequence. The results demonstrated that the Au-NPs/Gr nanocomposite was a promising substrate for the development of high-performance electrocatalysts for determination of KPC. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Rapid analysis of perchlorate in drinking water at parts per billion levels using microchip electrophoresis.

    PubMed

    Gertsch, Jana C; Noblitt, Scott D; Cropek, Donald M; Henry, Charles S

    2010-05-01

    A microchip capillary electrophoresis (MCE) system has been developed for the determination of perchlorate in drinking water. The United States Environmental Protection Agency (USEPA) recently proposed a health advisory limit for perchlorate in drinking water of 15 parts per billion (ppb), a level requiring large, sophisticated instrumentation, such as ion chromatography coupled with mass spectrometry (IC-MS), for detection. An inexpensive, portable system is desired for routine online monitoring applications of perchlorate in drinking water. Here, we present an MCE method using contact conductivity detection for perchlorate determination. The method has several advantages, including reduced analysis times relative to IC, inherent portability, high selectivity, and minimal sample pretreatment. Resolution of perchlorate from more abundant ions was achieved using zwitterionic, sulfobetaine surfactants, N-hexadecyl-N,N-dimethyl-3-ammonio-1-propane sulfonate (HDAPS) and N-tetradecyl-N,N-dimethyl-3-ammonio-1-propane sulfonate (TDAPS). The system performance and the optimization of the separation chemistry, including the use of these surfactants to resolve perchlorate from other anions, are discussed in this work. The system is capable of detection limits of 3.4 +/- 1.8 ppb (n = 6) in standards and 5.6 +/- 1.7 ppb (n = 6) in drinking water.

  9. Optimization of data analysis for the in vivo neutron activation analysis of aluminum in bone.

    PubMed

    Mohseni, H K; Matysiak, W; Chettle, D R; Byun, S H; Priest, N; Atanackovic, J; Prestwich, W V

    2016-10-01

    An existing system at McMaster University has been used for the in vivo measurement of aluminum in human bone. Precise and detailed analysis approaches are necessary to determine the aluminum concentration because of the low levels of aluminum found in the bone and the challenges associated with its detection. Phantoms resembling the composition of the human hand with varying concentrations of aluminum were made for testing the system prior to the application to human studies. A spectral decomposition model and a photopeak fitting model involving the inverse-variance weighted mean and a time-dependent analysis were explored to analyze the results and determine the model with the best performance and lowest minimum detection limit. The results showed that the spectral decomposition and the photopeak fitting model with the inverse-variance weighted mean both provided better results compared to the other methods tested. The spectral decomposition method resulted in a marginally lower detection limit (5μg Al/g Ca) compared to the inverse-variance weighted mean (5.2μg Al/g Ca), rendering both equally applicable to human measurements. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. Highly sensitive determination of diclofenac based on resin beads and a novel polyclonal antibody by using flow injection chemiluminescence competitive immunoassay

    NASA Astrophysics Data System (ADS)

    Shi, Jing; Xu, Mingxia; Tang, Qinghui; Zhao, Kang; Deng, Anping; Li, Jianguo

    2018-02-01

    A novel flow injection chemiluminescence immunoassay for simple, sensitive and low-cost detection of diclofenac was established based on specific binding of antigen and antibody. Carboxylic resin beads used as solid phase carrier materials provided good biocompatibility and large surface-to-volume ratio for modifying more coating antigen. There was a competitive process between the diclofenac in solution and the immobilized coating antigen to react with the limited binding sites of the polyclonal antibody to form the immunocomplex. The second antibody labelled with horseradish peroxidase was introduced into the immunosensor and trapped by captured polyclonal antibody against diclofenac, which could effectively amplify chemiluminescence signals of luminol-PIP-H2O2. Under optimal conditions, the diclofenac could be detected quantitatively. The chemiluminescence intensity decreased linearly with the logarithm of the diclofenac concentration in the range of 0.1-100 ng mL- 1 with a detection limit of 0.05 ng mL- 1 at a signal-to-noise ratio of 3. The immunosensor exhibited high sensitivity, specificity and acceptable stability. This easy-operated and cost-effective analytical method could be valuable for the diclofenac determination in real water samples.

  11. Analytical method development for the determination of emerging contaminants in water using supercritical-fluid chromatography coupled with diode-array detection.

    PubMed

    Del Carmen Salvatierra-Stamp, Vilma; Ceballos-Magaña, Silvia G; Gonzalez, Jorge; Ibarra-Galván, Valentin; Muñiz-Valencia, Roberto

    2015-05-01

    An analytical method using supercritical-fluid chromatography coupled with diode-array detection for the determination of seven emerging contaminants-two pharmaceuticals (carbamazepine and glyburide), three endocrine disruptors (17α-ethinyl estradiol, bisphenol A, and 17β-estradiol), one bactericide (triclosan), and one pesticide (diuron)-was developed and validated. These contaminants were chosen because of their frequency of use and their toxic effects on both humans and the environment. The optimized chromatographic separation on a Viridis BEH 2-EP column achieved baseline resolution for all compounds in less than 10 min. This separation was applied to environmental water samples after sample preparation. The optimized sample treatment involved a preconcentration step by means of solid-phase extraction using C18-OH cartridges. The proposed method was validated, finding recoveries higher than 94 % and limits of detection and limits of quantification in the range of 0.10-1.59 μg L(-1) and 0.31-4.83 μg L(-1), respectively. Method validation established the proposed method to be selective, linear, accurate, and precise. Finally, the method was successfully applied to environmental water samples.

  12. In Situ Determination of Bisphenol A in Beverage Using a Molybdenum Selenide/Reduced Graphene Oxide Nanoparticle Composite Modified Glassy Carbon Electrode.

    PubMed

    Shi, Rongguang; Liang, Jing; Zhao, Zongshan; Liu, Yi; Liu, Aifeng

    2018-05-22

    Due to the endocrine disturbing effects of bisphenol A (BPA) on organisms, rapid detection has become one of the most important techniques for monitoring its levels in the aqueous solutions associated with plastics and human beings. In this paper, a glassy carbon electrode (GCE) modified with molybdenum selenide/reduced graphene oxide (MoSe₂/rGO) was fabricated for in situ determination of bisphenol A in several beverages. The surface area of the electrode dramatically increases due to the existence of ultra-thin nanosheets in a flower-like structure of MoSe₂. Adding phosphotungstic acid in the electrolyte can significantly enhance the repeatability (RSD = 0.4%) and reproducibility (RSD = 2.2%) of the electrode. Under the optimized condition (pH = 6.5), the linear range of BPA was from 0.1 μM⁻100 μM and the detection limit was 0.015 μM (S/ N = 3). When using the as-prepared electrode for analyzing BPA in beverage samples without any pretreatments, the recoveries ranged from 98⁻107%, and the concentrations were from below the detection limit to 1.7 μM, indicating its potential prospect for routine analysis of BPA.

  13. Combined use of irreversible binding and MRM technology for low- and ultralow copy-number protein detection and quantitation.

    PubMed

    Kopylov, Arthur T; Zgoda, Victor G; Lisitsa, Andrew V; Archakov, Alexander I

    2013-03-01

    In this paper, we present a method for the determination of low- and ultralow copy-number proteins in biomaterials based on a combination of concentrating the protein from the sample onto cyanogen bromide-activated Sepharose 4B (via nonspecific binding of free amino groups) and MRM. The detection limit and the dependence of the MRM peak areas on the concentration of protein in the sample were determined using the proteins CYP102 and BSA, as a model system, both in solution and after their addition to human plasma. Nonspecific protein enrichment of proteins from diluted sample volumes of 10-50 mL was found to increase the range of linear dependence of the chromatographic peak area on concentration by more than three orders of magnitude, allowing a lower LOD limit (LLOD) of as low as 10(-18) M. At this LLOD, at least two tryptic peptides of CYP102 and BSA could be detected with S/N of ≥7.0. The results were equally good for samples containing pure protein mixtures and proteins spiked into diluted depleted human blood plasma. © 2013 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Biothiols induced colour change of silver nanoparticles: A colorimetric sensing strategy

    NASA Astrophysics Data System (ADS)

    Thomas, Ambily; Sivasankaran, Unni; Kumar, Krishnapillai Girish

    2018-01-01

    A sensor for the detection and determination of bio-thiols (glutathione (GSH) and cysteamine (Cyste)) has been developed by integrating the distinguished distance related optical characteristics of silver nanoparticles with the simplicity of colorimetric technique. In presence of these analytes, shift in surface plasmon resonance (SPR) absorption of silver nanoparticles (AgNPs) with change in its colour was observed. Yellow coloured AgNPs solution becomes colourless in presence of GSH and changes to red in presence of Cyste. FTIR, TEM and DLS studies were used to confirm the mechanism. The difference in absorption of AgNPs in the absence and presence of GSH was found to vary linearly in the range 1.00 × 10- 5 M to 5.00 × 10- 7 M concentration range with limit of detection at 3.68 × 10- 7 M. The method can also be applied to quantify Cyste in the range 1.10 × 10- 6 M to 5.00 × 10- 8 M with limit of detection at 1.80 × 10- 8 M. The utility of the proposed colorimetric assay is validated by determination of GSH and Cyste in artificial blood serum.

  15. [Determination of residual solvents in 7-amino-3-chloro cephalosporanic acid by gas chromatography].

    PubMed

    Ma, Li; Yao, Tong-wei

    2011-01-01

    To develop a gas chromatography method for determination of residual solvents in 7-amino-3-chloro cephalosporanic acid (7-ACCA). The residual levels of acetone, methanol, dichloromethane, ethyl acetate, isobutanol, pyridine and toluene in 7-ACCA were measured by gas chromatography using Agilent INNOWAX capillary column (30 m × 0.32 mm,0.5 μm). The initial column temperature was 70° maintained for 6 min and then raised (10°C/min) to 160°C for 1 min. Nitrogen gas was used as carrier and FID as detector. The flow of carrier was 1.0 ml/min, the temperature of injection port and detector was 200°C and 250°C, respectively. The limits of detection for acetone, methanol, dichloromethane, ethyl acetate, isobutanol, pyridine, toluene in 7-ACCA were 2.5 μg/ml, 1.5 μg/ml, 15 μg/ml, 2.5 μg/ml, 2.5 μg/ml, 2.5 μg/ml and 11 μg/ml, respectively. Only acetone was detected in the sample, and was less than the limits of Ch.P. The method can effectively detect the residual solvents in 7-ACCA.

  16. Surface Plasmon Resonance Based Sensitive Immunosensor for Benzaldehyde Detection

    NASA Astrophysics Data System (ADS)

    Onodera, Takeshi; Shimizu, Takuzo; Miura, Norio; Matsumoto, Kiyoshi; Toko, Kiyoshi

    Fragrant compounds used to add flavor to beverages remain in the manufacturing line after the beverage manufacturing process. Line cleanliness before the next manufacturing cycle is difficult to estimate by sensory analysis, making excessive washing necessary. A new measurement system to determine line cleanliness is desired. In this study, we attempted to detect benzaldehyde (Bz) using an anti-Bz monoclonal antibody (Bz-Ab) and a surface plasmon resonance (SPR) sensor. We fabricated two types of sensor chips using self-assembled monolayers (SAMs) and investigated which sensor surface exhibited higher sensitivity. In addition, anti-Bz antibody conjugated with horseradish peroxidase (HRP-Bz-Ab) was used to enhance the SPR signal. A detection limit of ca. 9ng/mL (ppb) was achieved using an immobilized 4-carboxybenzaldehyde sensor surface using SAMs containing ethylene glycol. When the HRP-Bz-Ab concentration was reduced to 30ng/mL, a detection limit of ca. 4ng/mL (ppb) was achieved for Bz.

  17. Collection and analysis of NASA clean room air samples

    NASA Technical Reports Server (NTRS)

    Sheldon, L. S.; Keever, J.

    1985-01-01

    The environment of the HALOE assembly clean room at NASA Langley Research Center is analyzed to determine the background levels of airborne organic compounds. Sampling is accomplished by pumping the clean room air through absorbing cartridges. For volatile organics, cartridges are thermally desorbed and then analyzed by gas chromatography and mass spectrometry, compounds are identified by searching the EPA/NIH data base using an interactive operator INCOS computer search algorithm. For semivolatile organics, cartridges are solvent entracted and concentrated extracts are analyzed by gas chromatography-electron capture detection, compound identification is made by matching gas chromatogram retention times with known standards. The detection limits for the semivolatile organics are; 0.89 ng cu m for dioctylphlhalate (DOP) and 1.6 ng cu m for polychlorinated biphenyls (PCB). The detection limit for volatile organics ranges from 1 to 50 parts per trillion. Only trace quantities of organics are detected, the DOP levels do not exceed 2.5 ng cu m and the PCB levels do not exceed 454 ng cu m.

  18. Mini-column assay for rapid detection of malachite green in fish.

    PubMed

    Shalaby, Ali R; Emam, Wafaa H; Anwar, Mervat M

    2017-07-01

    A simple, rapid and economical mini-column method for detecting malachite green (MG) residue in fish was developed. The method used a column with 2mm ID that was tightly packed with silica gel followed by alumina. Detection of MG was performed by viewing the developed mini-column at visible light by naked eye; where MG was seen as compact green band at the confluence of the silica gel layer with alumina layer. The limit of detection of the assay was 2ng which conform the minimum required performance limit (MRPL). Evaluation utility of the method indicated that all blank and spiked samples at levels below MRPL were assessed as accepted. The intensity of the green band increased whenever MG level in the extract increased; indicated that suggested mini-column technique could be used for semi-quantitative determination of MG in fish samples. The method can be used to select the questionable samples. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Direct liquid chromatography method for the simultaneous quantification of hydroxytyrosol and tyrosol in red wines.

    PubMed

    Piñeiro, Zulema; Cantos-Villar, Emma; Palma, Miguel; Puertas, Belen

    2011-11-09

    A validated HPLC method with fluorescence detection for the simultaneous quantification of hydroxytyrosol and tyrosol in red wines is described. Detection conditions for both compounds were optimized (excitation at 279 and 278 and emission at 631 and 598 nm for hydroxytyrosol and tyrosol, respectively). The validation of the analytical method was based on selectivity, linearity, robustness, detection and quantification limits, repeatability, and recovery. The detection and quantification limits in red wines were set at 0.023 and 0.076 mg L(-1) for hydroxytyrosol and at 0.007 and 0.024 mg L(-1) for tyrosol determination, respectively. Precision values, both within-day and between-day (n = 5), remained below 3% for both compounds. In addition, a fractional factorial experimental design was developed to analyze the influence of six different conditions on analysis. The final optimized HPLC-fluorescence method allowed the analysis of 30 nonpretreated Spanish red wines to evaluate their hydroxytyrosol and tyrosol contents.

  20. Real-time detection of hazardous materials in air

    NASA Astrophysics Data System (ADS)

    Schechter, Israel; Schroeder, Hartmut; Kompa, Karl L.

    1994-03-01

    A new detection system has been developed for real-time analysis of organic compounds in ambient air. It is based on multiphoton ionization by an unfocused laser beam in a single parallel-plate device. Thus, the ionization volume can be relatively large. The amount of laser created ions is determined quantitatively from the induced total voltage drop between the biased plates (Q equals (Delta) V(DOT)C). Mass information is obtained from computer analysis of the time-dependent signal. When a KrF laser (5 ev) is used, most of the organic compounds can be ionized in a two-photon process, but none of the standard components of atmospheric air are ionized by this process. Therefore, this instrument may be developed as a `sniffer' for organic materials. The method has been applied for benzene analysis in air. The detection limit is about 10 ppb. With a simple preconcentration technique the detection limit can be decreased to the sub-ppb range. Simple binary mixtures are also resolved.

  1. Gas chromatography with flame photometric detection of 31 organophosphorus pesticide residues in Alpinia oxyphylla dried fruits.

    PubMed

    Zhao, Xiangsheng; Kong, Weijun; Wei, Jianhe; Yang, Meihua

    2014-11-01

    A simple, rapid and effective gas chromatography-flame photometric detection method was established for simultaneous multi-component determination of 31 organophosphorus pesticides (OPPs) residues in Alpinia oxyphylla, which is widely consumed as a traditional medicine and food in China. Sample preparation was completed in a single step without any clean-up procedure. All pesticides expressed good linear relationships between 0.004 and 1.0 μg/mL with correlation coefficients higher than 0.9973. The method gave satisfactory recoveries for most pesticides. The limits of detection varied from 1 to 10 ng/mL, and the limits of quantification (LOQs) were between 4 and 30 ng/mL. The proposed method was successfully applied to 55 commercial samples purchased from five different areas. Five pesticide residues were detected in four (7.27%) samples. The positive samples were confirmed by gas chromatography with tandem mass spectrometry (GC-MS/MS). Copyright © 2014 Elsevier Ltd. All rights reserved.

  2. Fast and sensitive trace analysis of malachite green using a surface-enhanced Raman microfluidic sensor.

    PubMed

    Lee, Sangyeop; Choi, Junghyun; Chen, Lingxin; Park, Byungchoon; Kyong, Jin Burm; Seong, Gi Hun; Choo, Jaebum; Lee, Yeonjung; Shin, Kyung-Hoon; Lee, Eun Kyu; Joo, Sang-Woo; Lee, Kyeong-Hee

    2007-05-08

    A rapid and highly sensitive trace analysis technique for determining malachite green (MG) in a polydimethylsiloxane (PDMS) microfluidic sensor was investigated using surface-enhanced Raman spectroscopy (SERS). A zigzag-shaped PDMS microfluidic channel was fabricated for efficient mixing between MG analytes and aggregated silver colloids. Under the optimal condition of flow velocity, MG molecules were effectively adsorbed onto silver nanoparticles while flowing along the upper and lower zigzag-shaped PDMS channel. A quantitative analysis of MG was performed based on the measured peak height at 1615 cm(-1) in its SERS spectrum. The limit of detection, using the SERS microfluidic sensor, was found to be below the 1-2 ppb level and this low detection limit is comparable to the result of the LC-Mass detection method. In the present study, we introduce a new conceptual detection technology, using a SERS microfluidic sensor, for the highly sensitive trace analysis of MG in water.

  3. Simple determination of L-hydroxyproline in idiopathic pulmonary fibrosis lung tissues of rats using non-extractive high-performance liquid chromatography coupled with fluorescence detection after pre-column derivatization with novel synthetic 9-acetylimidazol-carbazole.

    PubMed

    Ren, Yan; Zhao, Juanjuan; Shi, Yanan; Chen, Caiyun; Chen, Xiangming; Lv, Changjun

    2017-08-05

    L-Hydroxyproline (L-Hyp) is an important biomarker for idiopathic pulmonary fibrosis (IPF). The quantitative methods based on high-performance liquid chromatography coupled with fluorescence detection after pre-column derivatization typically requires complicated derivatization conditions and obtains unstable derivatives. Here, a novel derivatization reagent, 9-acetylimidazol-carbazole, was synthesized for the first time to efficiently and rapidly label the amino groups of L-Hyp. The high-performance liquid chromatography method with pre-column derivatization was performed on an Agilent ZORBAX SB-C 18 column (4.6×250mm, 5μm). The product was measured using fluorescence detection at excitation and emission wavelengths of 232 and 370nm, respectively. The method was validated in specificity, linearity, limit of detection (66.7 fmol), limit of quantification (333.3fmol), intra-day precision (0.75%), inter-day precision (3.82%), stability (3.15%), and recovery (90.7-109.4%). The validated method was successfully applied to the determination of L-Hyp in the lung tissues of healthy and IPF rats. The results showed that the concentration of L-Hyp (3.64mg/g) in the IPF model was significantly higher than the concentration (2.33mg/g) in the healthy control group with P<0.01. This is a new method for the determination of L-Hyp and can be used for other amino acid-related studies in the future. Copyright © 2017. Published by Elsevier B.V.

  4. Evaluation of a tunable bandpass reaction cell for an inductively coupled plasma mass spectrometer for the determination of chromium and vanadium in serum and urine

    NASA Astrophysics Data System (ADS)

    Nixon, David E.; Neubauer, Kenneth R.; Eckdahl, Steven J.; Butz, John A.; Burritt, Mary F.

    2002-05-01

    A Dynamic Reaction Cell™ inductively coupled argon plasma mass spectrometer (DRC-ICP-MS) was evaluated for the determination of chromium and vanadium in serum and urine. Reaction cell conditions were evaluated for the elimination of ArC + and ClOH + interferences on chromium at mass 52 and OCl + on vanadium at mass 51. A diluent containing only 1% nitric acid and internal standards (Y and Ga) was used to prepare serum and urine for analysis. Instrument response calibration was achieved by using aqueous acidic standards spiked into pooled sera or urine matrices. The slopes of the calibration curves prepared in urine and serum matrices were nearly identical. On average, chromium detection limits are 2.5 times lower using the DRC than Zeeman graphite furnace atomic absorption spectrometry (ZGFAAS). Vanadium detection limits are approximately 50 times lower. Average detection limits achieved with DRC-ICP-MS are 0.075 μg Cr/l and 0.028 μg V/l. Average results for the analysis of National Institute of Standards and Technology Standard Reference Material (NIST SRM) 1598 Bovine Serum (attained over 22 days) are: 0.14 μg Cr/l and 0.068 μg V/l. The reference concentrations for vanadium and chromium in NIST SRM 1598 are (0.06) μg V/l and 0.14±0.08 μg Cr/l, respectively. Results for chromium and vanadium determinations on ICP-MS survey samples from the Toxocologie du Quebec are equivalent to those reported by high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS) for the same survey samples.

  5. Development of an enzyme immunoassay for the antibiotic cefquinome and its application for residue determination in cow's milk after therapeutical mastitis treatment.

    PubMed

    Thal, Johannes; Steffen, Monika; Meier, Bianca; Schneider, Elisabeth; Adriany, Ansgar; Usleber, Ewald

    2011-01-01

    The aim of this study was to develop and evaluate an enzyme immunoassay (EIA) for the cephalosporin antibiotic in milk, in combination with a new microbiological test system (brilliant black reduction test, BRT-P). Polyclonal antibodies against cefquinome were produced in rabbits, using cefquinome-keyhole limpet hemocyanine as the immunogen. These antibodies and a cefquinome-glucose oxidase conjugate were used in a competitive indirect EIA. The detection limit for cefquinome in milk was 1.5 ng ml(-1), recoveries were 80-128% at 4-40 ng ml(-1). Cross-reactivities with other cephalosporins/penicillins were all <1%. The EIA was used to determine cefquinome in incurred raw milk, the BRT-P (detection limit ≈ 20 ng ml(-1)) and a receptor assay (ßeta-s.t.a.r., detection limit ≈ 15 ng ml(-1)) were used in parallel. Five lactating cows, suffering from clinical mastitis, were treated with cefquinome by simultaneous intramammary and intramuscular injection. Cefquinome residues (maximum 10-27 μg ml(-1)) were most exclusively found in the udder quarter which was treated intramammary, residue levels in the other three quarters were low (<20 ng ml(-1)). Even in milk from intramammary-dosed quarters, residue levels fell below European Union maximum residue level (MRL, 20 μg kg(-1)) 2 days before the end of the withdrawal period. EIA, BRT-P, and ßeta-s.t.a.r. results showed acceptable agreement for milk samples, but the newly developed EIA is superior in aspects of sensitivity. In conclusion, this is the first one description of immunoassay and microbiological tests capable to determine cefquinome in milk at the MRL in incurred sample material.

  6. Statistical transformation and the interpretation of inpatient glucose control data from the intensive care unit.

    PubMed

    Saulnier, George E; Castro, Janna C; Cook, Curtiss B

    2014-05-01

    Glucose control can be problematic in critically ill patients. We evaluated the impact of statistical transformation on interpretation of intensive care unit inpatient glucose control data. Point-of-care blood glucose (POC-BG) data derived from patients in the intensive care unit for 2011 was obtained. Box-Cox transformation of POC-BG measurements was performed, and distribution of data was determined before and after transformation. Different data subsets were used to establish statistical upper and lower control limits. Exponentially weighted moving average (EWMA) control charts constructed from April, October, and November data determined whether out-of-control events could be identified differently in transformed versus nontransformed data. A total of 8679 POC-BG values were analyzed. POC-BG distributions in nontransformed data were skewed but approached normality after transformation. EWMA control charts revealed differences in projected detection of out-of-control events. In April, an out-of-control process resulting in the lower control limit being exceeded was identified at sample 116 in nontransformed data but not in transformed data. October transformed data detected an out-of-control process exceeding the upper control limit at sample 27 that was not detected in nontransformed data. Nontransformed November results remained in control, but transformation identified an out-of-control event less than 10 samples into the observation period. Using statistical methods to assess population-based glucose control in the intensive care unit could alter conclusions about the effectiveness of care processes for managing hyperglycemia. Further study is required to determine whether transformed versus nontransformed data change clinical decisions about the interpretation of care or intervention results. © 2014 Diabetes Technology Society.

  7. Statistical Transformation and the Interpretation of Inpatient Glucose Control Data From the Intensive Care Unit

    PubMed Central

    Saulnier, George E.; Castro, Janna C.

    2014-01-01

    Glucose control can be problematic in critically ill patients. We evaluated the impact of statistical transformation on interpretation of intensive care unit inpatient glucose control data. Point-of-care blood glucose (POC-BG) data derived from patients in the intensive care unit for 2011 was obtained. Box–Cox transformation of POC-BG measurements was performed, and distribution of data was determined before and after transformation. Different data subsets were used to establish statistical upper and lower control limits. Exponentially weighted moving average (EWMA) control charts constructed from April, October, and November data determined whether out-of-control events could be identified differently in transformed versus nontransformed data. A total of 8679 POC-BG values were analyzed. POC-BG distributions in nontransformed data were skewed but approached normality after transformation. EWMA control charts revealed differences in projected detection of out-of-control events. In April, an out-of-control process resulting in the lower control limit being exceeded was identified at sample 116 in nontransformed data but not in transformed data. October transformed data detected an out-of-control process exceeding the upper control limit at sample 27 that was not detected in nontransformed data. Nontransformed November results remained in control, but transformation identified an out-of-control event less than 10 samples into the observation period. Using statistical methods to assess population-based glucose control in the intensive care unit could alter conclusions about the effectiveness of care processes for managing hyperglycemia. Further study is required to determine whether transformed versus nontransformed data change clinical decisions about the interpretation of care or intervention results. PMID:24876620

  8. Design of experiments for amino acid extraction from tobacco leaves and their subsequent determination by capillary zone electrophoresis.

    PubMed

    Hodek, Ondřej; Křížek, Tomáš; Coufal, Pavel; Ryšlavá, Helena

    2017-03-01

    In this study, we optimized a method for the determination of free amino acids in Nicotiana tabacum leaves. Capillary electrophoresis with contactless conductivity detector was used for the separation of 20 proteinogenic amino acids in acidic background electrolyte. Subsequently, the conditions of extraction with HCl were optimized for the highest extraction yield of the amino acids because sample treatment of plant materials brings some specific challenges. Central composite face-centered design with fractional factorial design was used in order to evaluate the significance of selected factors (HCl volume, HCl concentration, sonication, shaking) on the extraction process. In addition, the composite design helped us to find the optimal values for each factor using the response surface method. The limits of detection and limits of quantification for the 20 proteinogenic amino acids were found to be in the order of 10 -5 and 10 -4  mol l -1 , respectively. Addition of acetonitrile to the sample was tested as a method commonly used to decrease limits of detection. Ambiguous results of this experiment pointed out some features of plant extract samples, which often required specific approaches. Suitability of the method for metabolomic studies was tested by analysis of a real sample, in which all amino acids, except for L-methionine and L-cysteine, were successfully detected. The optimized extraction process together with the capillary electrophoresis method can be used for the determination of proteinogenic amino acids in plant materials. The resulting inexpensive, simple, and robust method is well suited for various metabolomic studies in plants. As such, the method represents a valuable tool for research and practical application in the fields of biology, biochemistry, and agriculture.

  9. Chromogenic culture media or rapid immunochromatographic test: Which is better for detecting Klebsiella pneumoniae that produce OXA-48 and can they be used in blood and urine specimens.

    PubMed

    Genc, Ozlem; Aksu, Evrim

    2018-05-01

    Our goal was to compare a rapid test (OXA-48K-SeT) and four different chromogenic media (CHROMagar KPC, CHROMagar mSuperCARBA, ChromID Carba and ChromID OXA-48) for the detection of OXA-48 producing Klebsiella pneumoniae isolates and spiked urine/blood samples with these bacteria. In total 100 K.pneumoniae isolates, including 60 OXA-48 positive, 15 other carbapenemase producing, 15 Extended spectrum betalactamases (ESBL) positive and 10 carbapenem sensitive K.pneumoniae were included in the study. After all samples were inoculated into all chromogenic media, temocillin discs were placed onto the media. OXA-48K-SeT was studied according to the manufacturer's instructions and the lower detection limit was determined. Sensitivities and specificities of all chromogenic media and rapid test were detected as 100%. All of the OXA-48 producers were found resistant to temocillin on all chromogenic media. The lower detection limit of the rapid assay was determined as 10 6 in both direct bacterial samples and in spiked urine/blood samples. As a result, four chromogenic culture media and OXA-48 K-SeT can be used safely for detection of OXA-48 positive K.pneumoniae isolates. Although direct clinical specimens were not used, our study suggests that this media and OXA-48 K-SeT may be used in patient samples like blood and urine. Further studies are needed to assess this suggestion. Copyright © 2018 Elsevier B.V. All rights reserved.

  10. Levamisole: a Common Adulterant in Cocaine Street Samples Hindering Electrochemical Detection of Cocaine.

    PubMed

    de Jong, Mats; Florea, Anca; Vries, Anne-Mare de; van Nuijs, Alexander L N; Covaci, Adrian; Van Durme, Filip; Martins, José C; Samyn, Nele; De Wael, Karolien

    2018-04-17

    The present work investigates the electrochemical determination of cocaine in the presence of levamisole, one of the most common adulterants found in cocaine street samples. Levamisole misleads cocaine color tests, giving a blue color (positive test) even in the absence of cocaine. Moreover, the electrochemical detection of cocaine is also affected by the presence of levamisole, with a suppression of the oxidation signal of cocaine. When levamisole is present in the sample in ratios higher than 1:1, the cocaine signal is no longer detected, thus leading to false negative results. Mass spectrometry and nuclear magnetic resonance were used to investigate if the signal suppression is due to the formation of a complex between cocaine and levamisole in bulk solution. Strategies to eliminate this suppressing effect are further suggested in this manuscript. In a first approach, the increase of the pH of the sample solution from pH 7 to pH 12 allowed the voltammetric determination of cocaine in the presence of levamisole in a concentration range from 10 to 5000 μM at nonmodified graphite disposable electrodes with a detection limit of 5 μM. In a second approach, the graphite electrode was cathodically pretreated, resulting in the presence of oxidation peaks of both cocaine and levamisole, with a detection limit for cocaine of 3 μM over the linear range of concentrations from 10 to 2500 μM. Both these strategies have been successfully applied for the simultaneous detection of cocaine and levamisole in three street samples on unmodified graphite disposable electrodes.

  11. Functionalized gold nanoparticles for the detection of arsenic in water.

    PubMed

    Domínguez-González, R; González Varela, L; Bermejo-Barrera, P

    2014-01-01

    Gold nanoparticles are attractive as sensing materials because of their size and shape are related with their optical properties. The color change produced by the aggregation of functionalized AuNPs allows the detection of arsenic at low levels. A simple, cheap and fast analytical procedure to perform arsenic determination using functionalized gold nanoparticles (AuNPs) and VIS spectrometry as a detection technique is studied. Three different synthesis procedures to obtain the AuNPs and two different functionalization modes were studied. AuNPs functionalized with GSH-DTT-CYs-PDCA were selected as the most adequate. The correlation between the decrease in the absorbance signal and the arsenic concentration was good in the 2-20 µg l(-1)interval. Repeatability, expressed as average of RSD (%), obtained for the different arsenic concentrations studied was 0.6%. The average value of the analytical recovery was 99.7%. The detection and quantifications limits were 2.5 and 8.4 µg l(-1) respectively. These limits are sufficient to detect World Health Organization's guideline value of 10 µg l(-1). © 2013 Published by Elsevier B.V.

  12. Programmable and highly resolved in vitro detection of 5-methylcytosine by TALEs.

    PubMed

    Kubik, Grzegorz; Schmidt, Moritz J; Penner, Johanna E; Summerer, Daniel

    2014-06-02

    Gene expression is extensively regulated by specific patterns of genomic 5-methylcytosine (mC), but the ability to directly detect this modification at user-defined genomic loci is limited. One reason is the lack of molecules that discriminate between mC and cytosine (C) and at the same time provide inherent, programmable sequence-selectivity. Programmable transcription-activator-like effectors (TALEs) have been observed to exhibit mC-sensitivity in vivo, but to only a limited extent in vitro. We report an mC-detection assay based on TALE control of DNA replication that displays unexpectedly strong mC-discrimination ability in vitro. The status and level of mC modification at single positions in oligonucleotides can be determined unambiguously by this assay, independently of the overall target sequence. Moreover, discrimination is reliably observed for positions bound by N-terminal and central regions of TALEs. This indicates the wide scope and robustness of the approach for highly resolved mC detection and enabled the detection of a single mC in a large, eukaryotic genome. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Comprehensive sample analysis using high performance liquid chromatography with multi-detection.

    PubMed

    Pravadali, Sercan; Bassanese, Danielle N; Conlan, Xavier A; Francis, Paul S; Smith, Zoe M; Terry, Jessica M; Shalliker, R Andrew

    2013-11-25

    Herein we assess the separation space offered by a liquid chromatography system with an optimised uni-dimensional separation for the determination of the key chemical entities in the highly complex matrix of a tobacco leaf extract. Multiple modes of detection, including UV-visible absorbance, chemiluminescence (acidic potassium permanganate, manganese(IV), and tris(2,2'-bipyridine)ruthenium(III)), mass spectrometry and DPPH radical scavenging were used in an attempt to systematically reduce the data complexity of the sample whilst obtaining a greater degree of molecule-specific information. A large amount of chemical data was obtained, but several limitations in the ability to assign detector responses to particular compounds, even with the aid of complementary detection systems, were observed. Thirty-three compounds were detected via MS on the tobacco extract and 12 out of 32 compounds gave a peak height ratio (PHR) greater than 0.33 on one or more detectors. This paper serves as a case study of these limitations, illustrating why multidimensional chromatography is an important consideration when developing a comprehensive chemical detection system. Copyright © 2013 Elsevier B.V. All rights reserved.

  14. Multiplexed detection of mycotoxins in foods with a regenerable array.

    PubMed

    Ngundi, Miriam M; Shriver-Lake, Lisa C; Moore, Martin H; Ligler, Frances S; Taitt, Chris R

    2006-12-01

    The occurrence of different mycotoxins in cereal products calls for the development of a rapid, sensitive, and reliable detection method that is capable of analyzing samples for multiple toxins simultaneously. In this study, we report the development and application of a multiplexed competitive assay for the simultaneous detection of ochratoxin A (OTA) and deoxynivalenol (DON) in spiked barley, cornmeal, and wheat, as well as in naturally contaminated maize samples. Fluoroimmunoassays were performed with the Naval Research Laboratory array biosensor, by both a manual and an automated version of the system. This system employs evanescent-wave fluorescence excitation to probe binding events as they occur on the surface of a waveguide. Methanolic extracts of the samples were diluted threefold with buffer containing a mixture of fluorescent antibodies and were then passed over the arrays of mycotoxins immobilized on a waveguide. Fluorescent signals of the surface-bound antibody-antigen complexes decreased with increasing concentrations of free mycotoxins in the extract. After sample analysis was completed, surfaces were regenerated with 6 M guanidine hydrochloride in 50 mM glycine, pH 2.0. The limits of detection determined by the manual biosensor system were as follows: 1, 180, and 65 ng/g for DON and 1, 60, and 85 ng/g for OTA in cornmeal, wheat, and barley, respectively. The limits of detection in cornmeal determined with the automated array biosensor were 15 and 150 ng/g for OTA and DON, respectively.

  15. Faecal pollution along the southeastern coast of Florida and insight into the use of pepper mild mottle virus as an indicator.

    PubMed

    Symonds, E M; Sinigalliano, C; Gidley, M; Ahmed, W; McQuaig-Ulrich, S M; Breitbart, M

    2016-11-01

    To identify faecal pollution along the southeastern Florida coast and determine the performance of a reverse transcription-quantitative polymerase chain reaction (RT-qPCR) method for pepper mild mottle virus (PMMoV). In 2014, bimonthly surface water samples were collected from inlets, exposed to runoff and septic seepage, and coastal sites, exposed to ocean outfalls. Analysis of culturable enterococci and a suite of microbial source tracking (MST) markers (BacHum, CowM2, DogBact, HF183, HPyV, PMMoV) revealed faecal pollution, primarily of human origin, at all sites. Since PMMoV was detected more frequently than other MST markers, the process limits of quantification (undiluted to 10 -2 dilution) and detection (10 -2 dilution) for the RT-qPCR method were determined by seeding untreated wastewater into the coastal waters. Simulated quantitative microbial risk assessment, employing human norovirus as a reference pathogen, calculated a 0·286 median risk of gastrointestinal illness associated with the PMMoV limit of detection. All sites met the U.S. EPA recreational water criteria, despite detection of domestic wastewater-associated MST markers. PMMoV correlated only with human-associated MST markers. This study demonstrated that PMMoV is an important domestic wastewater-associated marker that should be included in the MST toolbox; therefore, future studies should thoroughly investigate the health risks associated with its detection and quantification in environmental waters. © 2016 The Society for Applied Microbiology.

  16. [Interest and limits of inductively coupled plasma mass spectrometry (ICP-MS) for urinary diagnosis of radionuclide internal contamination].

    PubMed

    Lecompte, Yannick; Bohand, Sandra; Laroche, Pierre; Cazoulat, Alain

    2013-01-01

    After a review of radiometric reference methods used in radiotoxicology, analytical performance of inductively coupled plasma mass spectrometry (ICP-MS) for the workplace urinary diagnosis of internal contamination by radionuclides are evaluated. A literature review (covering the period from 2000 to 2012) is performed to identify the different applications of ICP-MS in radiotoxicology for urine analysis. The limits of detection are compared to the recommendations of the International commission on radiological protection (ICRP 78: "Individual monitoring for internal exposure of workers"). Except one publication describing the determination of strontium-90 (β emitter), all methods using ICP-MS reported in the literature concern actinides (α emitters). For radionuclides with a radioactive period higher than 10(4) years, limits of detection are most often in compliance with ICRP publication 78 and frequently lower than radiometric methods. ICP-MS allows the specific determination of plutonium-239 + 240 isotopes which cannot be discriminated by α spectrometry. High resolution ICP-MS can also measure uranium isotopic ratios in urine for total uranium concentrations lower than 20 ng/L. The interest of ICP-MS in radiotoxicology concerns essentially the urinary measurement of long radioactive period actinides, particularly for uranium isotope ratio determination and 239 and 240 plutonium isotopes discrimination. Radiometric methods remain the most efficient for the majority of other radionuclides.

  17. Visual endpoint detection of Escherichia coli O157:H7 using isothermal Genome Exponential Amplification Reaction (GEAR) assay and malachite green.

    PubMed

    Jothikumar, Prithiviraj; Narayanan, Jothikumar; Hill, Vincent R

    2014-03-01

    Rapid and specific detection methods for bacterial agents in drinking water are important for disease prevention and responding to suspected contamination events. In this study, an isothermal Genome Exponential Amplification Reaction (GEAR) assay for Escherichia coli O157:H7 was designed specifically to recognize a 199-bp fragment of the lipopolysaccharide gene (rfbE) for rapid testing of water samples. The GEAR assay was found to be specific for E. coli O157:H7 using 10 isolates of E. coli O157:H7 and a panel of 86 bacterial controls. The GEAR assay was performed at a constant temperature of 65°C using SYTO 9 intercalating dye. Detection limits were determined to be 20 CFU for the GEAR assay. When SYTO 9 fluorescence was measured using a real-time PCR instrument, the assay had the same detection limit as when malachite green was added to the reaction mix and a characteristic blue color was visually observed in positive reactions. The study also found that 50 and 20 CFU of E. coli O157:H7 seeded into 100-liter of tap water could be detected by the GEAR assays after the sample was concentrated by hollow-fiber ultrafiltration (HFUF) and approximately 10% of HFUF concentrate was cultured using trypticase soy broth-novobiocin. When applied to 19 surface water samples collected from Tennessee and Kentucky, the GEAR assay and a published real-time PCR assay both detected E. coli O157:H7 in two of the samples. The results of this study indicate that the GEAR assay can be sensitive for rapid detection of E. coli O157:H7 in water samples using fluorometric instruments and visual endpoint determination. Published by Elsevier B.V.

  18. Use of Malachite Green-Loop Mediated Isothermal Amplification for Detection of Plasmodium spp. Parasites

    PubMed Central

    Lucchi, Naomi W.; Ljolje, Dragan; Silva-Flannery, Luciana; Udhayakumar, Venkatachalam

    2016-01-01

    Malaria elimination efforts are hampered by the lack of sensitive tools to detect infections with low-level parasitemia, usually below the threshold of standard diagnostic methods, microscopy and rapid diagnostic tests. Isothermal nucleic acid amplification assays such as the loop-mediated isothermal amplification (LAMP), are well suited for field use as they do not require thermal cyclers to run the test. However, the use of specialized equipment, as described by many groups, reduces the versatility of the LAMP technique as a simple tool for use in endemic countries. In this study, the use of the malachite green (MG) dye, as a visual endpoint readout, together with a simple mini heat block was evaluated for the detection of malaria parasites. The assay was performed for 1 hour at 63°C and the results scored by 3 independent human readers. The limit of detection of the assay was determined using well-quantified Plasmodium spp. infected reference samples and its utility in testing clinical samples was determined using 190 pre-treatment specimens submitted for reference diagnosis of imported malaria in the United States. Use of a simplified boil and spin methods of DNA extraction from whole blood and filter paper was also investigated. We demonstrate the accurate and sensitive detection of malaria parasites using this assay with a detection limit ranging between 1–8 parasites/μL, supporting its applicability for the detection of infections with low parasite burden. This assay is compatible with the use of a simple boil and spin sample preparation method from both whole blood and filter papers without a loss of sensitivity. The MG-LAMP assay described here has great potential to extend the reach of molecular tools to settings where they are needed. PMID:26967908

  19. Rapid determination of phenolic compounds and alkaloids of carob flour by improved liquid chromatography tandem mass spectrometry.

    PubMed

    Ortega, Nàdia; Macià, Alba; Romero, Maria-Paz; Trullols, Esther; Morello, Jose-Ramón; Anglès, Neus; Motilva, Maria-Jose

    2009-08-26

    An improved chromatographic method was developed using ultra-performance liquid chromatography-tandem mass spectrometry to identify and quantify phenolic compounds and alkaloids, theobromine and caffeine, in carob flour samples. The developed method has been validated in terms of speed, sensitivity, selectivity, peak efficiency, linearity, reproducibility, limits of detection, and limits of quantification. The chromatographic method allows the identification and quantification of 20 phenolic compounds, that is, phenolic acids, flavonoids, and their aglycone and glucoside forms, together with the determination of the alkaloids, caffeine and theobromine, at low concentration levels all in a short analysis time of less than 20 min.

  20. Loop-mediated isothermal amplification assay for detection of Haemophilus influenzae type b in cerebrospinal fluid.

    PubMed

    Kim, Dong Wook; Kilgore, Paul Evan; Kim, Eun Jin; Kim, Soon Ae; Anh, Dang Duc; Seki, Mitsuko

    2011-10-01

    Haemophilus influenzae type b (Hib) is one of the leading causes of meningitis in developing countries. To establish and evaluate a novel loop-mediated isothermal amplification (LAMP) assay for Hib, we designed a LAMP primer set targeting the Hib-specific capsulation locus. LAMP detected 10 copies of purified DNA in a 60-min reaction. This indicated that the detection limit of LAMP was >100-fold lower than the detection limits of both a PCR for the detection of bexA and a nested PCR for Hib (Hib PCR). No H. influenzae, other than Hib or control bacteria, was detected. Linear determination ranged from 10 to 1,000,000 microorganisms per reaction mixture using real-time turbidimetry. We evaluated the Hib LAMP assay using a set of 52 randomly selected cerebrospinal fluid (CSF) specimens obtained from children with suspected meningitis. For comparison, the CSF specimens were tested using a conventional Hib PCR assay. Hib was detected in 30 samples using LAMP and in 22 samples using the Hib PCR assay. The Hib PCR showed a clinical sensitivity of 73.3% and a clinical specificity of 100% relative to the Hib LAMP assay. These results suggest that further development and evaluation of the Hib LAMP will enhance the global diagnostic capability for Hib detection.

Top