Multicompartment Liquid-Cooling/Warming Protective Garments
NASA Technical Reports Server (NTRS)
Koscheyev, Victor S.; Leon, Gloria R.; Dancisak, Michael J.
2005-01-01
Shortened, multicompartment liquid-cooling / warming garments (LCWGs) for protecting astronauts, firefighters, and others at risk of exposure to extremes of temperature are undergoing development. Unlike prior liquid-circulation thermal-protection suits that provide either cooling or warming but not both, an LCWG as envisioned would provide cooling at some body locations and/or heating at other locations, as needed: For example, sometimes there is a need to cool the body core and to heat the extremities simultaneously. An LCWG garment of the type to be developed is said to be shortened because the liquid-cooling and - heating zones would not cover the whole body and, instead, would cover reduced areas selected for maximum heating and cooling effectiveness. Physiological research is under way to provide a rational basis for selection of the liquid-cooling and -heating areas. In addition to enabling better (relative to prior liquid-circulation garments) balancing of heat among different body regions, the use of selective heating and cooling in zones would contribute to a reduction in the amount of energy needed to operate a thermal-protection suit.
Laboratory evaluation of thermal protective clothing performance upon hot liquid splash.
Gholamreza, Farzan; Song, Guowen
2013-07-01
This study provides an understanding of heat and mass transfer through materials exposed to hot liquid splash, a relatively unexplored hazard in the safety clothing industry. Selected fabrics and layered systems were exposed to three hot liquids to study the effects of hot liquids and configuration. To explore the energy transfer mechanisms, a modified apparatus (based on ASTM F 2701-08) was developed to assess the protection performance provided by a fabric when exposed to a hot liquid. The modified test method allows measurement of the energy absorbed by the sensor, and with the use of a skin model, the time required to produce a second-degree burn injury was predicted. The preliminary testing demonstrated that mass transfer of the hot liquid through the fabric is the main factor contributing to burn injury. Key factors that determine the level of protection that a fabric system provides are summarized.
PREDICTING THE EFFECTIVENESS OF CHEMICAL-PROTECTIVE CLOTHING MODEL AND TEST METHOD DEVELOPMENT
A predictive model and test method were developed for determining the chemical resistance of protective polymeric gloves exposed to liquid organic chemicals. The prediction of permeation through protective gloves by solvents was based on theories of the solution thermodynamics of...
Development of a test method against hot alkaline chemical splashes.
Mäkinen, Helena; Nieminen, Kalevi; Mäki, Susanna; Siiskonen, Sirkku
2008-01-01
High temperature alkaline chemical liquids have caused injuries and hazardous situations in Finnish pulp manufacturing mills. There are no requirements and/or test method standards concerning protection against high temperature alkaline chemical splashes. This paper describes the test method development process to test and identify materials appropriate for hot liquid chemical hazard protection. In the first phase, the liquid was spilled through a stainless steel funnel and the protection performance was evaluated using a polyvinyl chloride (PVC) film under the test material. After several tentative improvements, a graphite crucible was used for heating and spilling the chemical, and a copper-coated K-type thermometer with 4 independent measuring areas was designed to measure the temperature under the material samples. The thermometer was designed to respond quickly so that peak temperatures could be measured. The main problem was to keep the spilled amount of chemical constant, which unfortunately resulted in significant variability in data.
Galvanic Liquid Applied Coating Development for Protection of Steel in Concrete
NASA Technical Reports Server (NTRS)
Curran, Joseph John; Curran, Jerry; MacDowell, Louis
2004-01-01
Corrosion of reinforcing steel in concrete is a major problem affecting NASA facilities at Kennedy Space Center (KSC), other government agencies, and the general public. Problems include damage to KSC launch support structures, transportation and marine infrastructures, as well as building structures. A galvanic liquid applied coating was developed at KSC in order to address this problem. The coating is a non-epoxy metal rich ethyl silicate liquid coating. The coating is applied as a liquid from initial stage to final stage. Preliminary data shows that this coating system exceeds the NACE 100 millivolt shift criterion. The remainder of the paper details the development of the coating system through the following phases: Phase I: Development of multiple formulations of the coating to achieve easy application characteristics, predictable galvanic activity, long-term protection, and minimum environmental impact. Phase II: Improvement of the formulations tested in Phase I including optimization of metallic loading as well as incorporation of humectants for continuous activation. Phase III: Application and testing of improved formulations on the test blocks. Phase IV: Incorporation of the final formulation upgrades onto large instrumented structures (slabs).
NASA Technical Reports Server (NTRS)
Cocchiaro, James E. (Editor); Mulder, Edwin J. (Editor); Gomez-Knight, Sylvia J. (Editor)
1999-01-01
This volume contains 37 unclassified/unlimited-distribution technical papers that were presented at the JANNAF 28th Propellant Development & Characterization Subcommittee (PDCS) and 17th Safety & Environmental Protection Subcommittee (S&EPS) Joint Meeting, held 26-30 April 1999 at the Town & Country Hotel and the Naval Submarine Base, San Diego, California. Volume II contains 29 unclassified/limited-distribution papers that were presented at the 28th PDCS and 17th S&EPS Joint Meeting. Volume III contains a classified paper that was presented at the 28th PDCS Meeting on 27 April 1999. Topics covered in PDCS sessions include: solid propellant rheology; solid propellant surveillance and aging; propellant process engineering; new solid propellant ingredients and formulation development; reduced toxicity liquid propellants; characterization of hypergolic propellants; and solid propellant chemical analysis methods. Topics covered in S&EPS sessions include: space launch range safety; liquid propellant hazards; vapor detection methods for toxic propellant vapors and other hazardous gases; toxicity of propellants, ingredients, and propellant combustion products; personal protective equipment for toxic liquid propellants; and demilitarization/treatment of energetic material wastes.
Diuzheva, Alina; Balogh, József; Jekő, József; Cziáky, Zoltán
2018-05-17
A dispersive liquid-liquid microextraction method for the simultaneous determination of 11 pharmaceuticals has been developed. The method is based on a microextraction procedure applied to wastewater samples from different regions of Hungary followed by high performance liquid chromatography with mass spectrometry. The effect of the nature of the extractant, dispersive solvent, different additives and extraction time were examined on the extraction efficiently of the dispersive liquid-liquid microextraction method. Under optimal conditions, the linearity for determining the pharmaceuticals was in the range of 1-500 ng mL -1 , with the correlation coefficients ranging from 0.9922 to 0.9995. The limits of detection and limits of quantification were in the range 0.31-6.65 and 0.93-22.18 ng mL -1 , respectively. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Amarouche, Nassima; Giraud, Matthieu; Forni, Luciano; Butte, Alessandro; Edwards, F; Borie, Nicolas; Renault, Jean-Hugues
2014-04-11
Protected synthetic peptide intermediates are often hydrophobic and not soluble in most common solvents. They are thus difficult to purify by preparative reversed-phase high-performance liquid chromatography (RP-HPLC), usually used for industrial production. It is then challenging to develop alternative chromatographic purification processes. Support-free liquid-liquid chromatographic techniques, including both hydrostatic (centrifugal partition chromatography or CPC) and hydrodynamic (counter-current chromatography or CCC) devices, are mainly involved in phytochemical studies but have also been applied to synthetic peptide purification. In this framework, two new biphasic solvent system compositions covering a wide range of polarity were developed to overcome solubility problems mentioned above. The new systems composed of heptane/tetrahydrofuran/acetonitrile/dimethylsulfoxide/water and heptane/methyl-tetrahydrofuran/N-methylpyrrolidone/water were efficiently used for the CPC purification of a 39-mer protected exenatide (Byetta®) and a 8-mer protected peptide intermediate of bivalirudin (Angiox®) synthesis. Phase compositions of the different biphasic solvent systems were determined by (1)H nuclear magnetic resonance. Physico-chemical properties including viscosity, density and interfacial tension of these biphasic systems are also described. Copyright © 2014 Elsevier B.V. All rights reserved.
Design and research of thermal protective material from short basalt fibres
NASA Astrophysics Data System (ADS)
Komkov, MA; Tarasov, VA; Boyarskaya, RA; Filimonov, AS
2016-10-01
Design and manufacture issues regarding highly porous thermal protection coatings of products by means of liquid filtration of short basalt fibres and mineral binder are considered. The technological process of manufacture of thermally loaded products from the short basalt fibres of thermal protective material (TPM) in the form of tiles and rings, was developed based on a liquid filtration method. The structural and mechanical properties of the highly porous TPM technological modes were determined. The thermal testing of the pipe model samples was carried out on a thermal bench, which showed the temperature on the coating reaching less than 60°C during a hot air run through the pipe at 400°C.
NASA Technical Reports Server (NTRS)
1980-01-01
Environmental Health Systems puts forth an increasing effort in the U.S. to develop ways of controlling noise, particularly in industrial environments due to Federal and State laws, labor union insistence and new findings relative to noise pollution impact on human health. NASA's Apollo guidance control system aided in the development of a noise protection product, SMART. The basis of all SMART products is SMART compound a liquid plastic mixture with exceptional energy/sound absorbing qualities. The basic compound was later refined for noise protection use.
NASA Astrophysics Data System (ADS)
Zhang, Wanshu; Zhang, Lanying; Liang, Xiao; Le Zhou; Xiao, Jiumei; Yu, Li; Li, Fasheng; Cao, Hui; Li, Kexuan; Yang, Zhou; Yang, Huai
2017-02-01
High-performance and cost-effective laser protection system is of crucial importance for the rapid advance of lasers in military and civilian fields leading to severe damages of human eyes and sensitive optical devices. However, it is crucially hindered by the angle-dependent protective effect and the complex preparation process. Here we demonstrate that angle-independence, good processibility, wavelength tunability, high optical density and good visibility can be effectuated simultaneously, by embedding dichroic anthraquinone dyes in a cholesteric liquid crystal matrix. More significantly, unconventional two-dimensional parabolic protection behavior is reported for the first time that in stark contrast to the existing protection systems, the overall parabolic protection behavior enables protective effect to increase with incident angles, hence providing omnibearing high-performance protection. The protective effect is controllable by dye concentration, LC cell thickness and CLC reflection efficiency, and the system can be made flexible enabling applications in flexible and even wearable protection devices. This research creates a promising avenue for the high-performance and cost-effective laser protection, and may foster the development of optical applications such as solar concentrators, car explosion-proof membrane, smart windows and polarizers.
Cryogenic Caging for Science Instrumentation
NASA Technical Reports Server (NTRS)
Penanen, Konstantin; Chui, Talso C.
2011-01-01
A method has been developed for caging science instrumentation to protect from pyro-shock and EDL (entry, descent, and landing) acceleration damage. Caging can be achieved by immersing the instrument (or its critical parts) in a liquid and solidifying the liquid by cooling. After the launch shock and/or after the payload has landed, the solid is heated up and evaporated.
46 CFR 153.932 - Goggles and protective clothing.
Code of Federal Regulations, 2011 CFR
2011-10-01
... CARRYING BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS Operations General Vessel Safety... or tight-fitting goggles for eye protection against splashing or spraying liquids if that person is...-fitting goggles for eye protection against splashing or spraying liquids if the person is: (1) In the area...
46 CFR 153.932 - Goggles and protective clothing.
Code of Federal Regulations, 2013 CFR
2013-10-01
... CARRYING BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS Operations General Vessel Safety... or tight-fitting goggles for eye protection against splashing or spraying liquids if that person is...-fitting goggles for eye protection against splashing or spraying liquids if the person is: (1) In the area...
46 CFR 153.932 - Goggles and protective clothing.
Code of Federal Regulations, 2010 CFR
2010-10-01
... CARRYING BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS Operations General Vessel Safety... or tight-fitting goggles for eye protection against splashing or spraying liquids if that person is...-fitting goggles for eye protection against splashing or spraying liquids if the person is: (1) In the area...
46 CFR 153.932 - Goggles and protective clothing.
Code of Federal Regulations, 2012 CFR
2012-10-01
... CARRYING BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS Operations General Vessel Safety... or tight-fitting goggles for eye protection against splashing or spraying liquids if that person is...-fitting goggles for eye protection against splashing or spraying liquids if the person is: (1) In the area...
46 CFR 153.932 - Goggles and protective clothing.
Code of Federal Regulations, 2014 CFR
2014-10-01
... CARRYING BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS Operations General Vessel Safety... or tight-fitting goggles for eye protection against splashing or spraying liquids if that person is...-fitting goggles for eye protection against splashing or spraying liquids if the person is: (1) In the area...
Protective Skins for Aerogel Monoliths
NASA Technical Reports Server (NTRS)
Leventis, Nicholas; Johnston, James C.; Kuczmarski, Maria A.; Meador, Ann B.
2007-01-01
A method of imparting relatively hard protective outer skins to aerogel monoliths has been developed. Even more than aerogel beads, aerogel monoliths are attractive as thermal-insulation materials, but the commercial utilization of aerogel monoliths in thermal-insulation panels has been inhibited by their fragility and the consequent difficulty of handling them. Therefore, there is a need to afford sufficient protection to aerogel monoliths to facilitate handling, without compromising the attractive bulk properties (low density, high porosity, low thermal conductivity, high surface area, and low permittivity) of aerogel materials. The present method was devised to satisfy this need. The essence of the present method is to coat an aerogel monolith with an outer polymeric skin, by painting or spraying. Apparently, the reason spraying and painting were not attempted until now is that it is well known in the aerogel industry that aerogels collapse in contact with liquids. In the present method, one prevents such collapse through the proper choice of coating liquid and process conditions: In particular, one uses a viscous polymer precursor liquid and (a) carefully controls the amount of liquid applied and/or (b) causes the liquid to become cured to the desired hard polymeric layer rapidly enough that there is not sufficient time for the liquid to percolate into the aerogel bulk. The method has been demonstrated by use of isocyanates, which, upon exposure to atmospheric moisture, become cured to polyurethane/polyurea-type coats. The method has also been demonstrated by use of commercial epoxy resins. The method could also be implemented by use of a variety of other resins, including polyimide precursors (for forming high-temperature-resistant protective skins) or perfluorinated monomers (for forming coats that impart hydrophobicity and some increase in strength).
Anti-Corrosive Powder Particles
NASA Technical Reports Server (NTRS)
Parker, Donald; MacDowell, Louis, III
2005-01-01
The National Aeronautics and Space Administration (NASA) seeks partners for a new approach in protecting embedded steel surfaces from corrosion. Corrosion of reinforced steel in concrete structures is a significant problem for NASA structures at Kennedy Space Center (KSC) because of the close proximity of the structures to salt spray from the nearby Atlantic Ocean. In an effort to minimize the damage to such structures, coatings were developed that could be applied as liquids to the external surfaces of a substrate in which the metal structures were embedded. The Metallic Pigment Powder Particle technology was developed by NASA at KSC. This technology combines the metallic materials into a uniform particle. The resultant powder can be sprayed simultaneously with a liquid binder onto the surface of concrete structures with a uniform distribution of the metallic pigment for optimum cathodic protection of the underlying steel in the concrete. Metallic Pigment Powder Particle technology improves upon the performance of an earlier NASA technology Liquid Galvanic Coating (U.S. Patent No. 6,627,065).
40 CFR 417.80 - Applicability; description of the manufacture of liquid soaps subcategory.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 29 2011-07-01 2009-07-01 true Applicability; description of the manufacture of liquid soaps subcategory. 417.80 Section 417.80 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS SOAP AND DETERGENT MANUFACTURING POINT SOURCE CATEGORY Manufacture of Liquid Soaps...
40 CFR 417.80 - Applicability; description of the manufacture of liquid soaps subcategory.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 28 2010-07-01 2010-07-01 true Applicability; description of the manufacture of liquid soaps subcategory. 417.80 Section 417.80 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS SOAP AND DETERGENT MANUFACTURING POINT SOURCE CATEGORY Manufacture of Liquid Soaps...
PROTECTIVE CLOTHING BASED ON PERMSELECTIVE MEMBRANE AND CARBON ADSORPTION
DOE Office of Scientific and Technical Information (OSTI.GOV)
J.G. Wijmans; J.O. Stull
2001-11-07
The goal of this project was to develop chemical protective clothing for use by DOE decontamination and decommissioning workers that is sufficiently water vapor permeable to keep the workers cool, thereby enhancing their productivity. This report describes the results of Phase II of a two-phase project to complete development of the novel permselective material and to test protective clothing made from the fabric. In Phase I a novel material incorporating a nonporous hydrophilic polyvinylacohol (PVA) layer, which is water vapor permeable but relatively impermeable to organic vapors, was developed. The results of the Phase I tests showed that the chemicalmore » resistance of the MTR material is comparable to that of Saranex/Tyvek materials, and that the comfort properties are closer to those of Tyvek (as measured in terms of CLO and permeability). Chemical resistance was measured using permeation tests against liquid dichloromethane. Comfort properties were ascertained by measuring the water vapor transmission of the material and by sweating manikin tests on whole protective suits. In addition, a cost/benefit analysis demonstrated that use of MTR's material technology could result in significant improvements in work productivity and cost savings if protective clothing items made from the new material were used more than once. In Phase II, MTR undertook a program to optimize the performance and production engineering for the new material technology. A partnership was formed with Kimberly-Clark Corporation to assist with a detailed evaluation of the MTR technology, and MTR used the services of Mr. Jeff Stull, President of the consulting firm International Personnel Protection, Inc., who conducted a detailed economic and application analysis for the developed fabric. The protective fabric manufacturing steps were simplified significantly, resulting in a 30% reduction in manufacturing costs and eliminating the necessity for capital investment in production equipment. Protective suits were prepared in collaboration with Kimberly-Clark Corporation and heat stress testing with human test subjects was carried out by the International Union of Operating Engineers (IUOE). The tests confirmed that the MTR protective fabric is significantly more comfortable than non-breathable materials. A cost analysis was developed from the properties of the optimized protective fabric and the results of the of the IUOE field study to determine the potential for the MTR material technology within the chemical protective clothing market. A detailed assessment of the specific chemical protective clothing applications for which the material can be used and its competitiveness with existing material technology, based both on expected performance and material/end item costs, was prepared. Three specific market opportunities identified for the novel protective fabric are: (1) liquid splash protective clothing for hazardous waste site operations, (2) liquid splash protective clothing for emergency response, and (3) Class 3 NFPA 1994-compliant protective clothing for civilian use during chemical terrorism incidents.« less
40 CFR 409.30 - Applicability; description of the liquid cane sugar refining subcategory.
Code of Federal Regulations, 2011 CFR
2011-07-01
... liquid cane sugar refining subcategory. 409.30 Section 409.30 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS SUGAR PROCESSING POINT SOURCE CATEGORY Liquid Cane Sugar Refining Subcategory § 409.30 Applicability; description of the liquid cane sugar refining...
40 CFR 409.30 - Applicability; description of the liquid cane sugar refining subcategory.
Code of Federal Regulations, 2010 CFR
2010-07-01
... liquid cane sugar refining subcategory. 409.30 Section 409.30 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS SUGAR PROCESSING POINT SOURCE CATEGORY Liquid Cane Sugar Refining Subcategory § 409.30 Applicability; description of the liquid cane sugar refining...
46 CFR 153.365 - Liquid overpressurization protection.
Code of Federal Regulations, 2010 CFR
2010-10-01
... pressure during liquid overfill at a specified cargo loading rate to that which the containment system is... 46 Shipping 5 2010-10-01 2010-10-01 false Liquid overpressurization protection. 153.365 Section... CARGOES SHIPS CARRYING BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS Design and...
46 CFR 153.365 - Liquid overpressurization protection.
Code of Federal Regulations, 2012 CFR
2012-10-01
... pressure during liquid overfill at a specified cargo loading rate to that which the containment system is... 46 Shipping 5 2012-10-01 2012-10-01 false Liquid overpressurization protection. 153.365 Section... CARGOES SHIPS CARRYING BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS Design and...
40 CFR 409.30 - Applicability; description of the liquid cane sugar refining subcategory.
Code of Federal Regulations, 2014 CFR
2014-07-01
... liquid cane sugar refining subcategory. 409.30 Section 409.30 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS SUGAR PROCESSING POINT SOURCE CATEGORY Liquid Cane Sugar Refining Subcategory § 409.30 Applicability; description of the liquid cane sugar refining...
40 CFR 409.30 - Applicability; description of the liquid cane sugar refining subcategory.
Code of Federal Regulations, 2013 CFR
2013-07-01
... liquid cane sugar refining subcategory. 409.30 Section 409.30 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS SUGAR PROCESSING POINT SOURCE CATEGORY Liquid Cane Sugar Refining Subcategory § 409.30 Applicability; description of the liquid cane sugar refining...
40 CFR 409.30 - Applicability; description of the liquid cane sugar refining subcategory.
Code of Federal Regulations, 2012 CFR
2012-07-01
... liquid cane sugar refining subcategory. 409.30 Section 409.30 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS SUGAR PROCESSING POINT SOURCE CATEGORY Liquid Cane Sugar Refining Subcategory § 409.30 Applicability; description of the liquid cane sugar refining...
40 CFR 65.106 - Standards: Valves in gas/vapor service and in light liquid service.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Standards: Valves in gas/vapor service and in light liquid service. (a) Compliance schedule. (1) The owner... 40 Protection of Environment 15 2010-07-01 2010-07-01 false Standards: Valves in gas/vapor service and in light liquid service. 65.106 Section 65.106 Protection of Environment ENVIRONMENTAL PROTECTION...
40 CFR 65.106 - Standards: Valves in gas/vapor service and in light liquid service.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Standards: Valves in gas/vapor service and in light liquid service. (a) Compliance schedule. (1) The owner... 40 Protection of Environment 16 2014-07-01 2014-07-01 false Standards: Valves in gas/vapor service and in light liquid service. 65.106 Section 65.106 Protection of Environment ENVIRONMENTAL PROTECTION...
40 CFR 65.106 - Standards: Valves in gas/vapor service and in light liquid service.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Standards: Valves in gas/vapor service and in light liquid service. (a) Compliance schedule. (1) The owner... 40 Protection of Environment 15 2011-07-01 2011-07-01 false Standards: Valves in gas/vapor service and in light liquid service. 65.106 Section 65.106 Protection of Environment ENVIRONMENTAL PROTECTION...
40 CFR 65.106 - Standards: Valves in gas/vapor service and in light liquid service.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Standards: Valves in gas/vapor service and in light liquid service. (a) Compliance schedule. (1) The owner... 40 Protection of Environment 16 2013-07-01 2013-07-01 false Standards: Valves in gas/vapor service and in light liquid service. 65.106 Section 65.106 Protection of Environment ENVIRONMENTAL PROTECTION...
40 CFR 65.106 - Standards: Valves in gas/vapor service and in light liquid service.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Standards: Valves in gas/vapor service and in light liquid service. (a) Compliance schedule. (1) The owner... 40 Protection of Environment 16 2012-07-01 2012-07-01 false Standards: Valves in gas/vapor service and in light liquid service. 65.106 Section 65.106 Protection of Environment ENVIRONMENTAL PROTECTION...
Development of an advanced rocket propellant handler's suit.
Doerr, D F
2001-01-01
Most launch vehicles and satellites in the US inventory rely upon the use of hypergolic rocket propellants, many of which are toxic to humans. These fuels and oxidizers, such as hydrazine and nitrogen tetroxide have threshold limit values as low as 0.01 PPM. It is essential to provide space workers handling these agents whole body protection as they are universally hazardous not only to the respiratory system, but the skin as well. This paper describes a new method for powering a whole body protective garment to assure the safety of ground servicing crews. A new technology has been developed through the small business innovative research program at the Kennedy Space Center. Currently, liquid air is used in the environmental control unit (ECU) that powers the propellant handlers suit (PHE). However, liquid air exhibits problems with attitude dependence, oxygen enrichment, and difficulty with reliable quantity measurement. The new technology employs the storage of the supply air as a supercritical gas. This method of air storage overcomes all of three problems above while maintaining high density storage at relatively low vessel pressures (<7000 kPa or approximately 1000 psi). A one hour prototype ECU was developed and tested to prove the feasibility of this concept. This was upgraded by the design of a larger supercritical dewar capable of holding 7 Kg of air, a supply which provides a 2 hour duration to the PHE. A third version is being developed to test the feasibility of replacing existing air cooling methodology with a liquid cooled garment for relief of heat stress in this warm Florida environment. Testing of the first one hour prototype yielded data comparable to the liquid air powered predecessor, but enjoyed advantages of attitude independence and oxygen level stability. Thermal data revealed heat stress relief at least as good as liquid air supplied units. The application of supercritical air technology to this whole body protective ensemble marked an advancement in the state-of-the-art in personal protective equipment. Not only was long duration environmental control provided, but it was done without a high pressure vessel. The unit met human performance needs for attitude independence, oxygen stability and relief of heat stress. This supercritical air (and oxygen) technology is suggested for microgravity applications in life support such as the Extravehicular Mobility Unit. c 2001. Elsevier Science Ltd. All rights reserved.
Development of an advanced rocket propellant handler's suit
NASA Technical Reports Server (NTRS)
Doerr, D. F.
2001-01-01
Most launch vehicles and satellites in the US inventory rely upon the use of hypergolic rocket propellants, many of which are toxic to humans. These fuels and oxidizers, such as hydrazine and nitrogen tetroxide have threshold limit values as low as 0.01 PPM. It is essential to provide space workers handling these agents whole body protection as they are universally hazardous not only to the respiratory system, but the skin as well. This paper describes a new method for powering a whole body protective garment to assure the safety of ground servicing crews. A new technology has been developed through the small business innovative research program at the Kennedy Space Center. Currently, liquid air is used in the environmental control unit (ECU) that powers the propellant handlers suit (PHE). However, liquid air exhibits problems with attitude dependence, oxygen enrichment, and difficulty with reliable quantity measurement. The new technology employs the storage of the supply air as a supercritical gas. This method of air storage overcomes all of three problems above while maintaining high density storage at relatively low vessel pressures (<7000 kPa or approximately 1000 psi). A one hour prototype ECU was developed and tested to prove the feasibility of this concept. This was upgraded by the design of a larger supercritical dewar capable of holding 7 Kg of air, a supply which provides a 2 hour duration to the PHE. A third version is being developed to test the feasibility of replacing existing air cooling methodology with a liquid cooled garment for relief of heat stress in this warm Florida environment. Testing of the first one hour prototype yielded data comparable to the liquid air powered predecessor, but enjoyed advantages of attitude independence and oxygen level stability. Thermal data revealed heat stress relief at least as good as liquid air supplied units. The application of supercritical air technology to this whole body protective ensemble marked an advancement in the state-of-the-art in personal protective equipment. Not only was long duration environmental control provided, but it was done without a high pressure vessel. The unit met human performance needs for attitude independence, oxygen stability and relief of heat stress. This supercritical air (and oxygen) technology is suggested for microgravity applications in life support such as the Extravehicular Mobility Unit. c 2001. Elsevier Science Ltd. All rights reserved.
Development of an advanced rocket propellant handler's suit
NASA Astrophysics Data System (ADS)
Doerr, DonaldF.
2001-08-01
Most launch vehicles and satellites in the US inventory rely upon the use of hypergolic rocket propellants, many of which are toxic to humans. These fuels and oxidizers, such as hydrazine and nitrogen tetroxide have threshold limit values as low as 0.01 PPM. It is essential to provide space workers handling these agents whole body protection as they are universally hazardous not only to the respiratory system, but the skin as well. This paper describes a new method for powering a whole body protective garment to assure the safety of ground servicing crews. A new technology has been developed through the small business innovative research program at the Kennedy Space Center. Currently, liquid air is used in the environmental control unit (ECU) that powers the propellant handlers suit (PHE). However, liquid air exhibits problems with attitude dependence, oxygen enrichment, and difficulty with reliable quantity measurement. The new technology employs the storage of the supply air as a supercritical gas. This method of air storage overcomes all of three problems above while maintaining high density storage at relatively low vessel pressures (<7000 kPa or ˜1000 psi). A one hour prototype ECU was developed and tested to prove the feasibility of this concept. This was upgraded by the design of a larger supercritical dewar capable of holding 7 Kg of air, a supply which provides a 2 hour duration to the PHE. A third version is being developed to test the feasibility of replacing existing air cooling methodology with a liquid cooled garment for relief of heat stress in this warm Florida environment. Testing of the first one hour prototype yielded data comprobable to the liquid air powered predecessor, but enjoyed advantages of attitude independence and oxygen level stability. Thermal data revealed heat stress relief at least as good as liquid air supplied units. The application of supercritical air technology to this whole body protective ensemble marked an advancement in the state-of-the-art in personal protective equipment. Not only was long duration environmental control provided, but it was done without a high pressure vessel. The unit met human performance needs for attitude independence, oxygen stability, and relief of heat stress. This supercritical air (and oxygen) technology is suggested for microgravity applications in life support such as the Extravehicular Mobility Unit.
NASA Technical Reports Server (NTRS)
Daniel, R. L.; Sanders, H. L.; Zimmerman, F. R.
1995-01-01
With the advent of new environmental laws restricting volatile organic compounds and hexavalent chrome emissions, 'environmentally safe' thermal spray coatings are being developed to replace the traditional corrosion protection chromate primers. A wire arc sprayed aluminum coating is being developed for corrosion protection of low pressure liquid hydrogen carrying ducts on the Space Shuttle Main Engine. Currently, this hardware utilizes a chromate primer to provide protection against corrosion pitting and stress corrosion cracking induced by the cryogenic operating environment. The wire are sprayed aluminum coating has been found to have good potential to provide corrosion protection for flight hardware in cryogenic applications. The coating development, adhesion test, corrosion test and cryogenic flexibility test results will be presented.
Liquid Coatings for Reducing Corrosion of Steel in Concrete
NASA Technical Reports Server (NTRS)
MacDowell, Louis G.; Curran, Joseph
2003-01-01
Inorganic coating materials are being developed to slow or stop corrosion of reinforcing steel members inside concrete structures. It is much simpler and easier to use these coating materials than it is to use conventional corrosion-inhibiting systems based on impressed electric currents. Unlike impressed electrical corrosion-inhibiting systems, these coatings do not require continuous consumption of electrical power and maintenance of power-supply equipment. Whereas some conventional systems involve the use of expensive arc-spray equipment to apply the metallic zinc used as the sacrificial anode material, the developmental coatings can be applied by use of ordinary paint sprayers. A coating material of the type under development is formulated as a liquid containing blended metallic particles and/or moisture-attracting compounds. The liquid mixture is sprayed onto a concrete structure. Experiments have shown that even though such a coat resides on the exterior surface, it generates a protective galvanic current that flows to the interior reinforcing steel members. By effectively transferring the corrosion process from the steel reinforcement to the exterior coating, the protective current slows or stops corrosion of the embedded steel. Specific formulations have been found to meet depolarization criteria of the National Association of Corrosion Engineers (NACE) for complete protection of steel reinforcing bars ("rebar") embedded in concrete.
Micropellets coated with Kollicoat® Smartseal 30D for taste masking in liquid oral dosage forms.
Dashevskiy, Andriy; Mohylyuk, Valentyn; Ahmed, Abid Riaz; Kolter, Karl; Guth, Felicitas; Bodmeier, Roland
2017-09-01
The objective of this study was to develop delivery systems for taste masking based on multiparticulates coated with Kollicoat ® Smartseal 30D formulated as liquid oral suspensions. Coating of particles containing bitter drugs with Kollicoat ® Smartseal reduced drug leaching into aqueous medium, especially when increasing pH, therefore can be used for the formulation of liquid dosage forms. Application of an intermediate layer of ion exchange resins between drug layer and coating can further decrease drug leaching into aqueous vehicle that is beneficial in terms of taste masking. Using optimized compositions of liquid vehicles such as addition of sugar alcohols and ion exchange resin, reconstitutable or ready-to-use liquid dosage forms with micropellets can be developed with bitter taste protection after redispersion lasting longer than 3 weeks, which exceeds the usual period of application.
Förster, Hans; Günther, Werner
2009-05-30
In Europe, the transport of flammable gases and liquids in tanks has been impacted by new developments: for example, the introduction of the vapour-balancing technique on a broad scale and the steady increase in the application of electronic components with their own power sources; furthermore, new regulatory policies like the ATEX Directives are being enforced in the European Union. With this background in mind, the present investigation aims to provide a basis for future developments of the relevant explosion protection regulations in the safety codes for the transport of dangerous goods (RID/ADR). Specifically, the concentration of gas in the air was measured under various practical conditions while tank vehicles were being loaded with flammable gases or liquids. These spot-test data were supplemented by systematic investigations at a road tanker placed in our test field. With respect to non-electrical ignition sources, a closer investigation of the effect of hot surfaces was carried out. With regard to improving the current regulations, the results of our investigation show that it would be reasonable to implement a stronger differentiation of the characteristics of the dangerous goods (gaseous/liquid, flashpoint) on the one hand and of the techniques applied (loading with and without vapour-balancing system) on the other hand. Conclusions for the further development of the current international regulations are proposed.
40 CFR 258.28 - Liquids restrictions.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 258.28 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES CRITERIA FOR MUNICIPAL SOLID WASTE LANDFILLS Operating Criteria § 258.28 Liquids restrictions. (a) Bulk or... (Paint Filter Liquids Test), included in “Test Methods for Evaluating Solid Waste, Physical/Chemical...
40 CFR 258.28 - Liquids restrictions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 258.28 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES CRITERIA FOR MUNICIPAL SOLID WASTE LANDFILLS Operating Criteria § 258.28 Liquids restrictions. (a) Bulk or... (Paint Filter Liquids Test), included in “Test Methods for Evaluating Solid Waste, Physical/Chemical...
40 CFR 264.1057 - Standards: Valves in gas/vapor service or in light liquid -service.
Code of Federal Regulations, 2014 CFR
2014-07-01
...: Valves in gas/vapor service or in light liquid -service. (a) Each valve in gas/vapor or light liquid... 40 Protection of Environment 26 2014-07-01 2014-07-01 false Standards: Valves in gas/vapor service or in light liquid -service. 264.1057 Section 264.1057 Protection of Environment ENVIRONMENTAL...
40 CFR 264.1057 - Standards: Valves in gas/vapor service or in light liquid -service.
Code of Federal Regulations, 2011 CFR
2011-07-01
...: Valves in gas/vapor service or in light liquid -service. (a) Each valve in gas/vapor or light liquid... 40 Protection of Environment 26 2011-07-01 2011-07-01 false Standards: Valves in gas/vapor service or in light liquid -service. 264.1057 Section 264.1057 Protection of Environment ENVIRONMENTAL...
40 CFR 264.1057 - Standards: Valves in gas/vapor service or in light liquid -service.
Code of Federal Regulations, 2010 CFR
2010-07-01
...: Valves in gas/vapor service or in light liquid -service. (a) Each valve in gas/vapor or light liquid... 40 Protection of Environment 25 2010-07-01 2010-07-01 false Standards: Valves in gas/vapor service or in light liquid -service. 264.1057 Section 264.1057 Protection of Environment ENVIRONMENTAL...
40 CFR 264.1057 - Standards: Valves in gas/vapor service or in light liquid -service.
Code of Federal Regulations, 2012 CFR
2012-07-01
...: Valves in gas/vapor service or in light liquid -service. (a) Each valve in gas/vapor or light liquid... 40 Protection of Environment 27 2012-07-01 2012-07-01 false Standards: Valves in gas/vapor service or in light liquid -service. 264.1057 Section 264.1057 Protection of Environment ENVIRONMENTAL...
40 CFR 264.1057 - Standards: Valves in gas/vapor service or in light liquid -service.
Code of Federal Regulations, 2013 CFR
2013-07-01
...: Valves in gas/vapor service or in light liquid -service. (a) Each valve in gas/vapor or light liquid... 40 Protection of Environment 27 2013-07-01 2013-07-01 false Standards: Valves in gas/vapor service or in light liquid -service. 264.1057 Section 264.1057 Protection of Environment ENVIRONMENTAL...
NASA Astrophysics Data System (ADS)
Barta, Daniel J.; Lange, Kevin; Anderson, Molly; Vonau, Walter
2016-07-01
Planetary protection represents an additional set of requirements that generally have not been considered by developers of technologies for Environmental Control and Life Support Systems (ECLSS). Forward contamination concerns will affect release of gases and discharge of liquids and solids, including what may be left behind after planetary vehicles are abandoned upon return to Earth. A crew of four using a state of the art ECLSS could generate as much as 4.3 metric tons of gaseous, liquid and solid wastes and trash during a 500-day surface stay. These may present issues and concerns for both planetary protection and planetary science. Certainly, further closure of ECLSS systems will be of benefit by greater reuse of consumable products and reduced generation of waste products. It can be presumed that planetary protection will affect technology development by constraining how technologies can operate: limiting or prohibiting certain kinds of operations or processes (e.g. venting); necessitating that other kinds of operations be performed (e.g. sterilization; filtration of vent lines); prohibiting what can be brought on a mission (e.g. extremophiles); creating needs for new capabilities/ technologies (e.g. containment). Although any planned venting could include filtration to eliminate micro-organisms from inadvertently exiting the spacecraft, it may be impossible to eliminate or filter habitat structural leakage. Filtration will add pressure drops impacting size of lines and ducts, affect fan size and energy requirements, and add consumable mass. Technologies that may be employed to remove biomarkers and microbial contamination from liquid and solid wastes prior to storage or release may include mineralization technologies such as incineration, super critical wet oxidation and pyrolysis. These technologies, however, come with significant penalties for mass, power and consumables. This paper will estimate the nature and amounts of materials generated during Mars transit and surface stays that may be impacted by planetary protection requirements or be controlled for the protection of planetary science.
Elastomeric Cellular Structure Enhanced by Compressible Liquid Filler
NASA Astrophysics Data System (ADS)
Sun, Yueting; Xu, Xiaoqing; Xu, Chengliang; Qiao, Yu; Li, Yibing
2016-05-01
Elastomeric cellular structures provide a promising solution for energy absorption. Their flexible and resilient nature is particularly relevant to protection of human bodies. Herein we develop an elastomeric cellular structure filled with nanoporous material functionalized (NMF) liquid. Due to the nanoscale infiltration in NMF liquid and its interaction with cell walls, the cellular structure has a much enhanced mechanical performance, in terms of loading capacity and energy absorption density. Moreover, it is validated that the structure is highly compressible and self-restoring. Its hyper-viscoelastic characteristics are elucidated.
Zhang, Min; Li, Songjing
2016-01-01
In this work, liquid colour-changing lenses for vision protection, camouflage and optical filtering are developed by circulating colour liquids through microfluidic channels on the lenses manually. Soft lithography technology is applied to fabricate the silicone liquid colour-changing layers with microfluidic channels on the lenses instead of mechanical machining. To increase the hardness and abrasion resistance of the silicone colour-changing layers on the lenses, proper fabrication parameters such as 6:1 (mass ration) mixing proportion and 100 °C curing temperature for 2 h are approved for better soft lithography process of the lenses. Meanwhile, a new surface treatment for the irreversible bonding of silicone colour-changing layer with optical resin (CR39) substrate lens by using 5 % (volume ratio) 3-Aminopropyltriethoxysilane solution is proposed. Vision protection, camouflage and optical filtering functions of the lenses are investigated with different designs of the channels and multi-layer structures. Each application can not only well achieve their functional demands, but also shows the advantages of functional flexibility, rapid prototyping and good controllability compared with traditional ways. Besides optometry, some other designs and applications of the lenses are proposed for potential utility in the future.
CENDRILLON CONTAINERS FOR THE TRANSPORT AND DISPENSING OF RADIOACTIVE LIQUIDS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vertut, J.
1963-01-01
Pumpkin-shaped containers were developed for safe transport and dispensing of radioactive liquids. Four different sizes varying in capacity from 3.5 to 50 liters are available, However, liquids with criticality hazards cannot be handled in these containers. The shape was chosen to make the container rest firmly on a flat surface and to prevent it from being turned over and remaining upset. The liquid is held in an inner container of stainless steel. It is surrounded by a protective lead shell made in two halves, so that the upper half can be taken off. The lead itself is cast into steelmore » shells to provide additional strength. Both halves are rendered liquid tight by asbestos packing. (M.C.G.)« less
49 CFR 176.315 - Fire protection requirements.
Code of Federal Regulations, 2014 CFR
2014-10-01
... Detailed Requirements for Class 3 (Flammable) and Combustible Liquid Materials § 176.315 Fire protection... (flammable) or combustible liquid for which it is required. Each fire extinguisher must be accessible to the... (flammable) and combustible liquids stowage areas must be fitted with an approved combination solid stream...
40 CFR 417.80 - Applicability; description of the manufacture of liquid soaps subcategory.
Code of Federal Regulations, 2014 CFR
2014-07-01
... manufacture of liquid soaps subcategory. 417.80 Section 417.80 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS SOAP AND DETERGENT MANUFACTURING POINT SOURCE CATEGORY Manufacture of Liquid Soaps Subcategory § 417.80 Applicability; description of the manufacture of...
40 CFR 417.80 - Applicability; description of the manufacture of liquid soaps subcategory.
Code of Federal Regulations, 2013 CFR
2013-07-01
... manufacture of liquid soaps subcategory. 417.80 Section 417.80 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS SOAP AND DETERGENT MANUFACTURING POINT SOURCE CATEGORY Manufacture of Liquid Soaps Subcategory § 417.80 Applicability; description of the manufacture of...
40 CFR 417.80 - Applicability; description of the manufacture of liquid soaps subcategory.
Code of Federal Regulations, 2012 CFR
2012-07-01
... manufacture of liquid soaps subcategory. 417.80 Section 417.80 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS SOAP AND DETERGENT MANUFACTURING POINT SOURCE CATEGORY Manufacture of Liquid Soaps Subcategory § 417.80 Applicability; description of the manufacture of...
40 CFR 264.314 - Special requirements for bulk and containerized liquids.
Code of Federal Regulations, 2010 CFR
2010-07-01
... containerized liquids. 264.314 Section 264.314 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... test must be used: Method 9095B (Paint Filter Liquids Test) as described in “Test Methods for Evaluating Solid Waste, Physical/Chemical Methods,” EPA Publication SW-846, as incorporated by reference in...
40 CFR 761.269 - Sampling liquid PCB remediation waste.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 31 2011-07-01 2011-07-01 false Sampling liquid PCB remediation waste. 761.269 Section 761.269 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC..., AND USE PROHIBITIONS Cleanup Site Characterization Sampling for PCB Remediation Waste in Accordance...
40 CFR 761.269 - Sampling liquid PCB remediation waste.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 32 2013-07-01 2013-07-01 false Sampling liquid PCB remediation waste. 761.269 Section 761.269 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC..., AND USE PROHIBITIONS Cleanup Site Characterization Sampling for PCB Remediation Waste in Accordance...
40 CFR 761.269 - Sampling liquid PCB remediation waste.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 31 2014-07-01 2014-07-01 false Sampling liquid PCB remediation waste. 761.269 Section 761.269 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC..., AND USE PROHIBITIONS Cleanup Site Characterization Sampling for PCB Remediation Waste in Accordance...
40 CFR 761.269 - Sampling liquid PCB remediation waste.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 32 2012-07-01 2012-07-01 false Sampling liquid PCB remediation waste. 761.269 Section 761.269 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC..., AND USE PROHIBITIONS Cleanup Site Characterization Sampling for PCB Remediation Waste in Accordance...
Wire-Arc-Sprayed Aluminum Protects Steel Against Corrosion
NASA Technical Reports Server (NTRS)
Zimmerman, Frank R.; Poorman, Richard; Sanders, Heather L.; Mckechnie, Timothy N.; Bonds, James W., Jr.; Daniel, Ronald L., Jr.
1995-01-01
Aluminum coatings wire-arc sprayed onto steel substrates found effective in protecting substrates against corrosion. Coatings also satisfy stringent requirements for adhesion and flexibility, both at room temperature and at temperatures as low as liquid hydrogen. Developed as alternatives to corrosion-inhibiting primers and paints required by law to be phased out because they contain and emit such toxic substances as chromium and volatile organic compounds.
NASA Astrophysics Data System (ADS)
Gharib, A.; Hagedorn, D.; Della Corte, A.; Fiamozzi Zignani, C.; Turtu, S.; Brown, D.; Rout, C.
2004-06-01
For the protection of the LHC superconducting magnets, about 2100 specially developed by-pass diodes were manufactured by DYNEX SEMICONDUCTOR LTD (Lincoln, GB) and about 1300 of these diodes were mounted into diode stacks and submitted to tests at cryogenic temperatures. To date about 800 dipole diode stacks and about 250 quadrupole diode stacks for the protection of the superconducting lattice dipole and lattice quadrupole magnets have been assembled at OCEM (Bologna,Italy) and successfully tested in liquid helium at ENEA (Frascati, Italy). This report gives an overview of the test results obtained so far. After a short description of the test installations and test procedures, a statistical analysis is presented for test data during diode production as well as for the performance of the diode stacks during testing in liquid helium, including failure rates and degradation of the diodes.
NASA Technical Reports Server (NTRS)
Paul, Heather; Trevino, Luis; Bue,Grant; Rugh, John
2006-01-01
An Advanced Automotive Manikin (ADAM) developed at the National Renewable Energy Laboratory (NREL) is used to evaluate NASA's liquid cooling garments (LCGs) used in advanced space suits for extravehicular applications. The manikin has 120 separate heated/sweating zones and is controlled by a finite element physiological model of the human thermoregulatory system. Previous testing showed the thermal sensation and comfort followed the expected trends as the LCG inlet fluid temperature was changed. The Phase II test data demonstrates the repeatability of ADAM by retesting the baseline LCG. Skin and core temperature predictions using ADAM in an LCG/Arctic suit combination are compared to NASA physiological data to validate the manikin/model. Additional LCG configurations are assessed using the manikin and compared to the baseline LCG. Results can extend to other personal protective clothing, including HAZMAT suits, nuclear/biological/chemical protective suits, and fire protection suits.
NASA Astrophysics Data System (ADS)
Narula, Manmeet Singh
Innovative concepts using fast flowing thin films of liquid metals (like lithium) have been proposed for the protection of the divertor surface in magnetic fusion devices. However, concerns exist about the possibility of establishing the required flow of liquid metal thin films because of the presence of strong magnetic fields which can cause flow disrupting MHD effects. A plan is underway to design liquid lithium based divertor protection concepts for NSTX, a small spherical torus experiment at Princeton. Of these, a promising concept is the use of modularized fast flowing liquid lithium film zones, as the divertor (called the NSTX liquid surface module concept or NSTX LSM). The dynamic response of the liquid metal film flow in a spatially varying magnetic field configuration is still unknown and it is suspected that some unpredicted effects might be lurking. The primary goal of the research work being reported in this dissertation is to provide qualitative and quantitative information on the liquid metal film flow dynamics under spatially varying magnetic field conditions, typical of the divertor region of a magnetic fusion device. The liquid metal film flow dynamics have been studied through a synergic experimental and numerical modeling effort. The Magneto Thermofluid Omnibus Research (MTOR) facility at UCLA has been used to design several experiments to study the MHD interaction of liquid gallium films under a scaled NSTX outboard divertor magnetic field environment. A 3D multi-material, free surface MHD modeling capability is under development in collaboration with HyPerComp Inc., an SBIR vendor. This numerical code called HIMAG provides a unique capability to model the equations of incompressible MHD with a free surface. Some parts of this modeling capability have been developed in this research work, in the form of subroutines for HIMAG. Extensive code debugging and benchmarking exercise has also been carried out. Finally, HIMAG has been used to study the MHD interaction of fast flowing liquid metal films under various divertor relevant magnetic field configurations through numerical modeling exercises.
40 CFR 65.108 - Standards: Connectors in gas/vapor service and in light liquid service.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Standards: Connectors in gas/vapor service and in light liquid service. (a) Compliance schedule. Except as... 40 Protection of Environment 16 2014-07-01 2014-07-01 false Standards: Connectors in gas/vapor service and in light liquid service. 65.108 Section 65.108 Protection of Environment ENVIRONMENTAL...
40 CFR 65.108 - Standards: Connectors in gas/vapor service and in light liquid service.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Standards: Connectors in gas/vapor service and in light liquid service. (a) Compliance schedule. Except as... 40 Protection of Environment 16 2012-07-01 2012-07-01 false Standards: Connectors in gas/vapor service and in light liquid service. 65.108 Section 65.108 Protection of Environment ENVIRONMENTAL...
40 CFR 65.108 - Standards: Connectors in gas/vapor service and in light liquid service.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Standards: Connectors in gas/vapor service and in light liquid service. (a) Compliance schedule. Except as... 40 Protection of Environment 15 2010-07-01 2010-07-01 false Standards: Connectors in gas/vapor service and in light liquid service. 65.108 Section 65.108 Protection of Environment ENVIRONMENTAL...
40 CFR 65.108 - Standards: Connectors in gas/vapor service and in light liquid service.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Standards: Connectors in gas/vapor service and in light liquid service. (a) Compliance schedule. Except as... 40 Protection of Environment 15 2011-07-01 2011-07-01 false Standards: Connectors in gas/vapor service and in light liquid service. 65.108 Section 65.108 Protection of Environment ENVIRONMENTAL...
40 CFR 65.108 - Standards: Connectors in gas/vapor service and in light liquid service.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Standards: Connectors in gas/vapor service and in light liquid service. (a) Compliance schedule. Except as... 40 Protection of Environment 16 2013-07-01 2013-07-01 false Standards: Connectors in gas/vapor service and in light liquid service. 65.108 Section 65.108 Protection of Environment ENVIRONMENTAL...
40 CFR 98.381 - Reporting threshold.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 21 2011-07-01 2011-07-01 false Reporting threshold. 98.381 Section 98.381 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) MANDATORY GREENHOUSE GAS REPORTING Suppliers of Coal-based Liquid Fuels § 98.381 Reporting threshold. Any supplier of coal-to-liquid products who...
40 CFR 98.381 - Reporting threshold.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 21 2014-07-01 2014-07-01 false Reporting threshold. 98.381 Section 98.381 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) MANDATORY GREENHOUSE GAS REPORTING Suppliers of Coal-based Liquid Fuels § 98.381 Reporting threshold. Any supplier of coal-to-liquid products who...
40 CFR 98.381 - Reporting threshold.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 22 2013-07-01 2013-07-01 false Reporting threshold. 98.381 Section 98.381 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) MANDATORY GREENHOUSE GAS REPORTING Suppliers of Coal-based Liquid Fuels § 98.381 Reporting threshold. Any supplier of coal-to-liquid products who...
Protected Lithium-Metal Anodes in Batteries: From Liquid to Solid.
Yang, Chunpeng; Fu, Kun; Zhang, Ying; Hitz, Emily; Hu, Liangbing
2017-09-01
High-energy lithium-metal batteries are among the most promising candidates for next-generation energy storage systems. With a high specific capacity and a low reduction potential, the Li-metal anode has attracted extensive interest for decades. Dendritic Li formation, uncontrolled interfacial reactions, and huge volume effect are major hurdles to the commercial application of Li-metal anodes. Recent studies have shown that the performance and safety of Li-metal anodes can be significantly improved via organic electrolyte modification, Li-metal interface protection, Li-electrode framework design, separator coating, and so on. Superior to the liquid electrolytes, solid-state electrolytes are considered able to inhibit problematic Li dendrites and build safe solid Li-metal batteries. Inspired by the bright prospects of solid Li-metal batteries, increasing efforts have been devoted to overcoming the obstacles of solid Li-metal batteries, such as low ionic conductivity of the electrolyte and Li-electrolyte interfacial problems. Here, the approaches to protect Li-metal anodes from liquid batteries to solid-state batteries are outlined and analyzed in detail. Perspectives regarding the strategies for developing Li-metal anodes are discussed to facilitate the practical application of Li-metal batteries. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Lu, Yehu; Song, Guowen; Wang, Faming
2015-03-01
Hot liquid hazards existing in work environments are shown to be a considerable risk for industrial workers. In this study, the predicted protection from fabric was assessed by a modified hot liquid splash tester. In these tests, conditions with and without an air spacer were applied. The protective performance of a garment exposed to hot water spray was investigated by a spray manikin evaluation system. Three-dimensional body scanning technique was used to characterize the air gap size between the protective clothing and the manikin skin. The relationship between bench scale test and manikin test was discussed and the regression model was established to predict the overall percentage of skin burn while wearing protective clothing. The results demonstrated strong correlations between bench scale test and manikin test. Based on these studies, the overall performance of protective clothing against hot water spray can be estimated on the basis of the results of the bench scale hot water splashes test and the information of air gap size entrapped in clothing. The findings provide effective guides for the design and material selection while developing high performance protective clothing. Published by Oxford University Press on behalf of the British Occupational Hygiene Society 2014.
Control Algorithms For Liquid-Cooled Garments
NASA Technical Reports Server (NTRS)
Drew, B.; Harner, K.; Hodgson, E.; Homa, J.; Jennings, D.; Yanosy, J.
1988-01-01
Three algorithms developed for control of cooling in protective garments. Metabolic rate inferred from temperatures of cooling liquid outlet and inlet, suitably filtered to account for thermal lag of human body. Temperature at inlet adjusted to value giving maximum comfort at inferred metabolic rate. Applicable to space suits, used for automatic control of cooling in suits worn by workers in radioactive, polluted, or otherwise hazardous environments. More effective than manual control, subject to frequent, overcompensated adjustments as level of activity varies.
Code of Federal Regulations, 2010 CFR
2010-07-01
.... Within 4 hours from the time you collect the liquid mercury, you must transfer it from each temporary... 40 Protection of Environment 13 2010-07-01 2010-07-01 false Work Practice Standards-Requirements for Mercury Liquid Collection 4 Table 4 to Subpart IIIII of Part 63 Protection of Environment...
46 CFR 39.20-7 - Tankship liquid overfill protection-T/ALL.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 1 2012-10-01 2012-10-01 false Tankship liquid overfill protection-T/ALL. 39.20-7 Section 39.20-7 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY TANK VESSELS VAPOR CONTROL SYSTEMS Design and Equipment § 39.20-7 Tankship liquid overfill protection—T/ALL. (a) Each cargo tank of a...
46 CFR 39.20-7 - Tankship liquid overfill protection-T/ALL.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 1 2011-10-01 2011-10-01 false Tankship liquid overfill protection-T/ALL. 39.20-7 Section 39.20-7 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY TANK VESSELS VAPOR CONTROL SYSTEMS Design and Equipment § 39.20-7 Tankship liquid overfill protection—T/ALL. (a) Each cargo tank of a...
46 CFR 39.20-7 - Tankship liquid overfill protection-T/ALL.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 1 2010-10-01 2010-10-01 false Tankship liquid overfill protection-T/ALL. 39.20-7 Section 39.20-7 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY TANK VESSELS VAPOR CONTROL SYSTEMS Design and Equipment § 39.20-7 Tankship liquid overfill protection—T/ALL. (a) Each cargo tank of a...
40 CFR 63.173 - Standards: Agitators in gas/vapor service and in light liquid service.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Equipment Leaks § 63.173 Standards: Agitators in gas/vapor service and in light liquid service. (a)(1) Each... 40 Protection of Environment 9 2011-07-01 2011-07-01 false Standards: Agitators in gas/vapor service and in light liquid service. 63.173 Section 63.173 Protection of Environment ENVIRONMENTAL...
40 CFR 63.1028 - Agitators in gas and vapor service and in light liquid service standards.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Standards § 63.1028 Agitators in gas and vapor service and in light liquid service standards. (a) Compliance... 40 Protection of Environment 11 2013-07-01 2013-07-01 false Agitators in gas and vapor service and in light liquid service standards. 63.1028 Section 63.1028 Protection of Environment ENVIRONMENTAL...
40 CFR 63.1028 - Agitators in gas and vapor service and in light liquid service standards.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Standards § 63.1028 Agitators in gas and vapor service and in light liquid service standards. (a) Compliance... 40 Protection of Environment 11 2014-07-01 2014-07-01 false Agitators in gas and vapor service and in light liquid service standards. 63.1028 Section 63.1028 Protection of Environment ENVIRONMENTAL...
40 CFR 63.1008 - Connectors in gas and vapor service and in light liquid service standards.
Code of Federal Regulations, 2013 CFR
2013-07-01
... § 63.1008 Connectors in gas and vapor service and in light liquid service standards. (a) Compliance... 40 Protection of Environment 11 2013-07-01 2013-07-01 false Connectors in gas and vapor service and in light liquid service standards. 63.1008 Section 63.1008 Protection of Environment ENVIRONMENTAL...
40 CFR 63.173 - Standards: Agitators in gas/vapor service and in light liquid service.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Equipment Leaks § 63.173 Standards: Agitators in gas/vapor service and in light liquid service. (a)(1) Each... 40 Protection of Environment 10 2012-07-01 2012-07-01 false Standards: Agitators in gas/vapor service and in light liquid service. 63.173 Section 63.173 Protection of Environment ENVIRONMENTAL...
40 CFR 63.1025 - Valves in gas and vapor service and in light liquid service standards.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Standards § 63.1025 Valves in gas and vapor service and in light liquid service standards. (a) Compliance... 40 Protection of Environment 11 2014-07-01 2014-07-01 false Valves in gas and vapor service and in light liquid service standards. 63.1025 Section 63.1025 Protection of Environment ENVIRONMENTAL...
40 CFR 63.1028 - Agitators in gas and vapor service and in light liquid service standards.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Standards § 63.1028 Agitators in gas and vapor service and in light liquid service standards. (a) Compliance... 40 Protection of Environment 10 2011-07-01 2011-07-01 false Agitators in gas and vapor service and in light liquid service standards. 63.1028 Section 63.1028 Protection of Environment ENVIRONMENTAL...
40 CFR 63.1008 - Connectors in gas and vapor service and in light liquid service standards.
Code of Federal Regulations, 2014 CFR
2014-07-01
... § 63.1008 Connectors in gas and vapor service and in light liquid service standards. (a) Compliance... 40 Protection of Environment 11 2014-07-01 2014-07-01 false Connectors in gas and vapor service and in light liquid service standards. 63.1008 Section 63.1008 Protection of Environment ENVIRONMENTAL...
40 CFR 63.1025 - Valves in gas and vapor service and in light liquid service standards.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Standards § 63.1025 Valves in gas and vapor service and in light liquid service standards. (a) Compliance... 40 Protection of Environment 10 2010-07-01 2010-07-01 false Valves in gas and vapor service and in light liquid service standards. 63.1025 Section 63.1025 Protection of Environment ENVIRONMENTAL...
40 CFR 65.109 - Standards: Agitators in gas/vapor service and in light liquid service.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Standards: Agitators in gas/vapor service and in light liquid service. (a) Compliance schedule. The owner or... 40 Protection of Environment 16 2012-07-01 2012-07-01 false Standards: Agitators in gas/vapor service and in light liquid service. 65.109 Section 65.109 Protection of Environment ENVIRONMENTAL...
40 CFR 63.173 - Standards: Agitators in gas/vapor service and in light liquid service.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Equipment Leaks § 63.173 Standards: Agitators in gas/vapor service and in light liquid service. (a)(1) Each... 40 Protection of Environment 10 2014-07-01 2014-07-01 false Standards: Agitators in gas/vapor service and in light liquid service. 63.173 Section 63.173 Protection of Environment ENVIRONMENTAL...
40 CFR 63.1009 - Agitators in gas and vapor service and in light liquid service standards.
Code of Federal Regulations, 2014 CFR
2014-07-01
... § 63.1009 Agitators in gas and vapor service and in light liquid service standards. (a) Compliance... 40 Protection of Environment 11 2014-07-01 2014-07-01 false Agitators in gas and vapor service and in light liquid service standards. 63.1009 Section 63.1009 Protection of Environment ENVIRONMENTAL...
40 CFR 265.1057 - Standards: Valves in gas/vapor service or in light liquid service.
Code of Federal Regulations, 2011 CFR
2011-07-01
....1057 Standards: Valves in gas/vapor service or in light liquid service. (a) Each valve in gas/vapor or... 40 Protection of Environment 26 2011-07-01 2011-07-01 false Standards: Valves in gas/vapor service or in light liquid service. 265.1057 Section 265.1057 Protection of Environment ENVIRONMENTAL...
40 CFR 63.1009 - Agitators in gas and vapor service and in light liquid service standards.
Code of Federal Regulations, 2011 CFR
2011-07-01
... § 63.1009 Agitators in gas and vapor service and in light liquid service standards. (a) Compliance... 40 Protection of Environment 10 2011-07-01 2011-07-01 false Agitators in gas and vapor service and in light liquid service standards. 63.1009 Section 63.1009 Protection of Environment ENVIRONMENTAL...
40 CFR 265.1057 - Standards: Valves in gas/vapor service or in light liquid service.
Code of Federal Regulations, 2010 CFR
2010-07-01
....1057 Standards: Valves in gas/vapor service or in light liquid service. (a) Each valve in gas/vapor or... 40 Protection of Environment 25 2010-07-01 2010-07-01 false Standards: Valves in gas/vapor service or in light liquid service. 265.1057 Section 265.1057 Protection of Environment ENVIRONMENTAL...
40 CFR 63.1025 - Valves in gas and vapor service and in light liquid service standards.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Standards § 63.1025 Valves in gas and vapor service and in light liquid service standards. (a) Compliance... 40 Protection of Environment 10 2011-07-01 2011-07-01 false Valves in gas and vapor service and in light liquid service standards. 63.1025 Section 63.1025 Protection of Environment ENVIRONMENTAL...
40 CFR 63.1008 - Connectors in gas and vapor service and in light liquid service standards.
Code of Federal Regulations, 2010 CFR
2010-07-01
... § 63.1008 Connectors in gas and vapor service and in light liquid service standards. (a) Compliance... 40 Protection of Environment 10 2010-07-01 2010-07-01 false Connectors in gas and vapor service and in light liquid service standards. 63.1008 Section 63.1008 Protection of Environment ENVIRONMENTAL...
40 CFR 65.109 - Standards: Agitators in gas/vapor service and in light liquid service.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Standards: Agitators in gas/vapor service and in light liquid service. (a) Compliance schedule. The owner or... 40 Protection of Environment 15 2011-07-01 2011-07-01 false Standards: Agitators in gas/vapor service and in light liquid service. 65.109 Section 65.109 Protection of Environment ENVIRONMENTAL...
40 CFR 63.1028 - Agitators in gas and vapor service and in light liquid service standards.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Standards § 63.1028 Agitators in gas and vapor service and in light liquid service standards. (a) Compliance... 40 Protection of Environment 11 2012-07-01 2012-07-01 false Agitators in gas and vapor service and in light liquid service standards. 63.1028 Section 63.1028 Protection of Environment ENVIRONMENTAL...
40 CFR 65.109 - Standards: Agitators in gas/vapor service and in light liquid service.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Standards: Agitators in gas/vapor service and in light liquid service. (a) Compliance schedule. The owner or... 40 Protection of Environment 15 2010-07-01 2010-07-01 false Standards: Agitators in gas/vapor service and in light liquid service. 65.109 Section 65.109 Protection of Environment ENVIRONMENTAL...
40 CFR 265.1057 - Standards: Valves in gas/vapor service or in light liquid service.
Code of Federal Regulations, 2012 CFR
2012-07-01
....1057 Standards: Valves in gas/vapor service or in light liquid service. (a) Each valve in gas/vapor or... 40 Protection of Environment 27 2012-07-01 2012-07-01 false Standards: Valves in gas/vapor service or in light liquid service. 265.1057 Section 265.1057 Protection of Environment ENVIRONMENTAL...
40 CFR 63.173 - Standards: Agitators in gas/vapor service and in light liquid service.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Equipment Leaks § 63.173 Standards: Agitators in gas/vapor service and in light liquid service. (a)(1) Each... 40 Protection of Environment 9 2010-07-01 2010-07-01 false Standards: Agitators in gas/vapor service and in light liquid service. 63.173 Section 63.173 Protection of Environment ENVIRONMENTAL...
40 CFR 265.1057 - Standards: Valves in gas/vapor service or in light liquid service.
Code of Federal Regulations, 2013 CFR
2013-07-01
....1057 Standards: Valves in gas/vapor service or in light liquid service. (a) Each valve in gas/vapor or... 40 Protection of Environment 27 2013-07-01 2013-07-01 false Standards: Valves in gas/vapor service or in light liquid service. 265.1057 Section 265.1057 Protection of Environment ENVIRONMENTAL...
40 CFR 63.174 - Standards: Connectors in gas/vapor service and in light liquid service.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Equipment Leaks § 63.174 Standards: Connectors in gas/vapor service and in light liquid service. (a) The... 40 Protection of Environment 10 2013-07-01 2013-07-01 false Standards: Connectors in gas/vapor service and in light liquid service. 63.174 Section 63.174 Protection of Environment ENVIRONMENTAL...
40 CFR 63.174 - Standards: Connectors in gas/vapor service and in light liquid service.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Equipment Leaks § 63.174 Standards: Connectors in gas/vapor service and in light liquid service. (a) The... 40 Protection of Environment 10 2012-07-01 2012-07-01 false Standards: Connectors in gas/vapor service and in light liquid service. 63.174 Section 63.174 Protection of Environment ENVIRONMENTAL...
40 CFR 63.1008 - Connectors in gas and vapor service and in light liquid service standards.
Code of Federal Regulations, 2012 CFR
2012-07-01
... § 63.1008 Connectors in gas and vapor service and in light liquid service standards. (a) Compliance... 40 Protection of Environment 11 2012-07-01 2012-07-01 false Connectors in gas and vapor service and in light liquid service standards. 63.1008 Section 63.1008 Protection of Environment ENVIRONMENTAL...
40 CFR 63.1009 - Agitators in gas and vapor service and in light liquid service standards.
Code of Federal Regulations, 2010 CFR
2010-07-01
... § 63.1009 Agitators in gas and vapor service and in light liquid service standards. (a) Compliance... 40 Protection of Environment 10 2010-07-01 2010-07-01 false Agitators in gas and vapor service and in light liquid service standards. 63.1009 Section 63.1009 Protection of Environment ENVIRONMENTAL...
40 CFR 63.1009 - Agitators in gas and vapor service and in light liquid service standards.
Code of Federal Regulations, 2012 CFR
2012-07-01
... § 63.1009 Agitators in gas and vapor service and in light liquid service standards. (a) Compliance... 40 Protection of Environment 11 2012-07-01 2012-07-01 false Agitators in gas and vapor service and in light liquid service standards. 63.1009 Section 63.1009 Protection of Environment ENVIRONMENTAL...
40 CFR 63.1028 - Agitators in gas and vapor service and in light liquid service standards.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Standards § 63.1028 Agitators in gas and vapor service and in light liquid service standards. (a) Compliance... 40 Protection of Environment 10 2010-07-01 2010-07-01 false Agitators in gas and vapor service and in light liquid service standards. 63.1028 Section 63.1028 Protection of Environment ENVIRONMENTAL...
40 CFR 63.1025 - Valves in gas and vapor service and in light liquid service standards.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Standards § 63.1025 Valves in gas and vapor service and in light liquid service standards. (a) Compliance... 40 Protection of Environment 11 2013-07-01 2013-07-01 false Valves in gas and vapor service and in light liquid service standards. 63.1025 Section 63.1025 Protection of Environment ENVIRONMENTAL...
40 CFR 63.174 - Standards: Connectors in gas/vapor service and in light liquid service.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Equipment Leaks § 63.174 Standards: Connectors in gas/vapor service and in light liquid service. (a) The... 40 Protection of Environment 10 2014-07-01 2014-07-01 false Standards: Connectors in gas/vapor service and in light liquid service. 63.174 Section 63.174 Protection of Environment ENVIRONMENTAL...
40 CFR 65.109 - Standards: Agitators in gas/vapor service and in light liquid service.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Standards: Agitators in gas/vapor service and in light liquid service. (a) Compliance schedule. The owner or... 40 Protection of Environment 16 2013-07-01 2013-07-01 false Standards: Agitators in gas/vapor service and in light liquid service. 65.109 Section 65.109 Protection of Environment ENVIRONMENTAL...
40 CFR 63.174 - Standards: Connectors in gas/vapor service and in light liquid service.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Equipment Leaks § 63.174 Standards: Connectors in gas/vapor service and in light liquid service. (a) The... 40 Protection of Environment 9 2011-07-01 2011-07-01 false Standards: Connectors in gas/vapor service and in light liquid service. 63.174 Section 63.174 Protection of Environment ENVIRONMENTAL...
40 CFR 63.174 - Standards: Connectors in gas/vapor service and in light liquid service.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Equipment Leaks § 63.174 Standards: Connectors in gas/vapor service and in light liquid service. (a) The... 40 Protection of Environment 9 2010-07-01 2010-07-01 false Standards: Connectors in gas/vapor service and in light liquid service. 63.174 Section 63.174 Protection of Environment ENVIRONMENTAL...
40 CFR 63.1009 - Agitators in gas and vapor service and in light liquid service standards.
Code of Federal Regulations, 2013 CFR
2013-07-01
... § 63.1009 Agitators in gas and vapor service and in light liquid service standards. (a) Compliance... 40 Protection of Environment 11 2013-07-01 2013-07-01 false Agitators in gas and vapor service and in light liquid service standards. 63.1009 Section 63.1009 Protection of Environment ENVIRONMENTAL...
40 CFR 265.1057 - Standards: Valves in gas/vapor service or in light liquid service.
Code of Federal Regulations, 2014 CFR
2014-07-01
....1057 Standards: Valves in gas/vapor service or in light liquid service. (a) Each valve in gas/vapor or... 40 Protection of Environment 26 2014-07-01 2014-07-01 false Standards: Valves in gas/vapor service or in light liquid service. 265.1057 Section 265.1057 Protection of Environment ENVIRONMENTAL...
40 CFR 63.173 - Standards: Agitators in gas/vapor service and in light liquid service.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Equipment Leaks § 63.173 Standards: Agitators in gas/vapor service and in light liquid service. (a)(1) Each... 40 Protection of Environment 10 2013-07-01 2013-07-01 false Standards: Agitators in gas/vapor service and in light liquid service. 63.173 Section 63.173 Protection of Environment ENVIRONMENTAL...
40 CFR 63.1008 - Connectors in gas and vapor service and in light liquid service standards.
Code of Federal Regulations, 2011 CFR
2011-07-01
... § 63.1008 Connectors in gas and vapor service and in light liquid service standards. (a) Compliance... 40 Protection of Environment 10 2011-07-01 2011-07-01 false Connectors in gas and vapor service and in light liquid service standards. 63.1008 Section 63.1008 Protection of Environment ENVIRONMENTAL...
40 CFR 63.1025 - Valves in gas and vapor service and in light liquid service standards.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Standards § 63.1025 Valves in gas and vapor service and in light liquid service standards. (a) Compliance... 40 Protection of Environment 11 2012-07-01 2012-07-01 false Valves in gas and vapor service and in light liquid service standards. 63.1025 Section 63.1025 Protection of Environment ENVIRONMENTAL...
40 CFR 65.109 - Standards: Agitators in gas/vapor service and in light liquid service.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Standards: Agitators in gas/vapor service and in light liquid service. (a) Compliance schedule. The owner or... 40 Protection of Environment 16 2014-07-01 2014-07-01 false Standards: Agitators in gas/vapor service and in light liquid service. 65.109 Section 65.109 Protection of Environment ENVIRONMENTAL...
NASA Technical Reports Server (NTRS)
Cocchiaro, James E. (Editor); Filliben, Jeff D. (Editor); Watson, Anne H. (Editor)
1997-01-01
In the Propellant Development and Characterization Subcommittee (PDCS) meeting, topics included: the analysis, characterization, and processing of propellants and propellant ingredients; chemical reactivity; liquid propellants; test methods; rheology; surveillance and aging; and process engineering. In the Safety and Environmental Protection Subcommittee (S&EPS) meeting, topics covered included: hydrazine propellant vapor detection methods; toxicity of propellants and propellants; explosives safety; atmospheric modeling and risk assessment of toxic releases; reclamation, disposal, and demilitarization methods; and remediation of explosives or propellant contaminated sites.
Topological Luttinger liquids from decorated domain walls
NASA Astrophysics Data System (ADS)
Parker, Daniel E.; Scaffidi, Thomas; Vasseur, Romain
2018-04-01
We introduce a systematic construction of a gapless symmetry-protected topological phase in one dimension by "decorating" the domain walls of Luttinger liquids. The resulting strongly interacting phases provide a concrete example of a gapless symmetry-protected topological (gSPT) phase with robust symmetry-protected edge modes. Using boundary conformal field theory arguments, we show that while the bulks of such gSPT phases are identical to conventional Luttinger liquids, their boundary critical behavior is controlled by a different, strongly coupled renormalization group fixed point. Our results are checked against extensive density matrix renormalization group calculations.
Liquid Galvanic Coatings for Protection of Imbedded Metals
NASA Technical Reports Server (NTRS)
MacDowell, Louis G. (Inventor); Curran, Joseph J. (Inventor)
2003-01-01
Coating compositions and methods of their use are described herein for the reduction of corrosion in imbedded metal structures. The coatings are applied as liquids to an external surface of a substrate in which the metal structures are imbedded. The coatings are subsequently allowed to dry. The liquid applied coatings provide galvanic protection to the imbedded metal structures. Continued protection can be maintained with periodic reapplication of the coating compositions, as necessary, to maintain electrical continuity. Because the coatings may be applied using methods similar to standard paints, and because the coatings are applied to external surfaces of the substrates in which the metal structures are imbedded, the corresponding corrosion protection may be easily maintained. The coating compositions are particularly useful in the protection of metal-reinforced concrete.
Personal Protective Equipment In Animal Research - Back To The Basics (A review paper)
2016-12-02
injury or impairment from physical contact .8 OSHA requires that many categories of PPE meet or be equivalent to standards developed by the American...for the design and construction of protective apparel are based on the anticipated location and degree of liquid contact during expected use. In...particular, critical zones of surgical and isolation gowns are identified as those where direct contact with blood, body fluids, and/or other potentially
Optimisation of nasal swab analysis by liquid scintillation counting.
Dai, Xiongxin; Liblong, Aaron; Kramer-Tremblay, Sheila; Priest, Nicholas; Li, Chunsheng
2012-06-01
When responding to an emergency radiological incident, rapid methods are needed to provide the physicians and radiation protection personnel with an early estimation of possible internal dose resulting from the inhalation of radionuclides. This information is needed so that appropriate medical treatment and radiological protection control procedures can be implemented. Nasal swab analysis, which employs swabs swiped inside a nostril followed by liquid scintillation counting of alpha and beta activity on the swab, could provide valuable information to quickly identify contamination of the affected population. In this study, various parameters (such as alpha/beta discrimination, swab materials, counting time and volume of scintillation cocktail etc) were evaluated in order to optimise the effectiveness of the nasal swab analysis method. An improved nasal swab procedure was developed by replacing cotton swabs with polyurethane-tipped swabs. Liquid scintillation counting was performed using a Hidex 300SL counter with alpha/beta pulse shape discrimination capability. Results show that the new method is more reliable than existing methods using cotton swabs and effectively meets the analysis requirements for screening personnel in an emergency situation. This swab analysis procedure is also applicable to wipe tests of surface contamination to minimise the source self-absorption effect on liquid scintillation counting.
40 CFR 60.482-7a - Standards: Valves in gas/vapor service and in light liquid service.
Code of Federal Regulations, 2010 CFR
2010-07-01
...-7a Standards: Valves in gas/vapor service and in light liquid service. (a)(1) Each valve shall be... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Standards: Valves in gas/vapor service and in light liquid service. 60.482-7a Section 60.482-7a Protection of Environment ENVIRONMENTAL...
40 CFR 60.482-7a - Standards: Valves in gas/vapor service and in light liquid service.
Code of Federal Regulations, 2014 CFR
2014-07-01
...-7a Standards: Valves in gas/vapor service and in light liquid service. (a)(1) Each valve shall be... 40 Protection of Environment 7 2014-07-01 2014-07-01 false Standards: Valves in gas/vapor service and in light liquid service. 60.482-7a Section 60.482-7a Protection of Environment ENVIRONMENTAL...
40 CFR 60.482-7a - Standards: Valves in gas/vapor service and in light liquid service.
Code of Federal Regulations, 2013 CFR
2013-07-01
...-7a Standards: Valves in gas/vapor service and in light liquid service. (a)(1) Each valve shall be... 40 Protection of Environment 7 2013-07-01 2013-07-01 false Standards: Valves in gas/vapor service and in light liquid service. 60.482-7a Section 60.482-7a Protection of Environment ENVIRONMENTAL...
40 CFR 60.482-7a - Standards: Valves in gas/vapor service and in light liquid service.
Code of Federal Regulations, 2011 CFR
2011-07-01
...-7a Standards: Valves in gas/vapor service and in light liquid service. (a)(1) Each valve shall be... 40 Protection of Environment 6 2011-07-01 2011-07-01 false Standards: Valves in gas/vapor service and in light liquid service. 60.482-7a Section 60.482-7a Protection of Environment ENVIRONMENTAL...
40 CFR 60.482-7a - Standards: Valves in gas/vapor service and in light liquid service.
Code of Federal Regulations, 2012 CFR
2012-07-01
...-7a Standards: Valves in gas/vapor service and in light liquid service. (a)(1) Each valve shall be... 40 Protection of Environment 7 2012-07-01 2012-07-01 false Standards: Valves in gas/vapor service and in light liquid service. 60.482-7a Section 60.482-7a Protection of Environment ENVIRONMENTAL...
Tarozzi, Alessandro; Mahajan, Aprajit; Blackburn, Brian; Kopf, Dan; Krishnan, Lakshmi; Yoong, Joanne
2014-07-01
We describe findings from the first large-scale cluster randomized controlled trial in a developing country that evaluates the uptake of a health-protecting technology, insecticide-treated bednets (ITNs), through micro-consumer loans, as compared to free distribution and control conditions. Despite a relatively high price, 52 percent of sample households purchased ITNs, highlighting the role of liquidity constraints in explaining earlier low adoption rates. We find mixed evidence of improvements in malaria indices. We interpret the results and their implications within the debate about cost sharing, sustainability and liquidity constraints in public health initiatives in developing countries.
Blast shock wave mitigation using the hydraulic energy redirection and release technology.
Chen, Yun; Huang, Wei; Constantini, Shlomi
2012-01-01
A hydraulic energy redirection and release technology has been developed for mitigating the effects of blast shock waves on protected objects. The technology employs a liquid-filled plastic tubing as a blast overpressure transformer to transfer kinetic energy of blast shock waves into hydraulic energy in the plastic tubings. The hydraulic energy is redirected through the plastic tubings to the openings at the lower ends, and then is quickly released with the liquid flowing out through the openings. The samples of the specifically designed body armor in which the liquid-filled plastic tubings were installed vertically as the outer layer of the body armor were tested. The blast test results demonstrated that blast overpressure behind the body armor samples was remarkably reduced by 97% in 0.2 msec after the liquid flowed out of its appropriate volume through the openings. The results also suggested that a volumetric liquid surge might be created when kinetic energy of blast shock wave was transferred into hydraulic energy to cause a rapid physical movement or displacement of the liquid. The volumetric liquid surge has a strong destructive power, and can cause a noncontact, remote injury in humans (such as blast-induced traumatic brain injury and post-traumatic stress disorder) if it is created in cardiovascular system. The hydraulic energy redirection and release technology can successfully mitigate blast shock waves from the outer surface of the body armor. It should be further explored as an innovative approach to effectively protect against blast threats to civilian and military personnel.
Blast Shock Wave Mitigation Using the Hydraulic Energy Redirection and Release Technology
Chen, Yun; Huang, Wei; Constantini, Shlomi
2012-01-01
A hydraulic energy redirection and release technology has been developed for mitigating the effects of blast shock waves on protected objects. The technology employs a liquid-filled plastic tubing as a blast overpressure transformer to transfer kinetic energy of blast shock waves into hydraulic energy in the plastic tubings. The hydraulic energy is redirected through the plastic tubings to the openings at the lower ends, and then is quickly released with the liquid flowing out through the openings. The samples of the specifically designed body armor in which the liquid-filled plastic tubings were installed vertically as the outer layer of the body armor were tested. The blast test results demonstrated that blast overpressure behind the body armor samples was remarkably reduced by 97% in 0.2 msec after the liquid flowed out of its appropriate volume through the openings. The results also suggested that a volumetric liquid surge might be created when kinetic energy of blast shock wave was transferred into hydraulic energy to cause a rapid physical movement or displacement of the liquid. The volumetric liquid surge has a strong destructive power, and can cause a noncontact, remote injury in humans (such as blast-induced traumatic brain injury and post-traumatic stress disorder) if it is created in cardiovascular system. The hydraulic energy redirection and release technology can successfully mitigate blast shock waves from the outer surface of the body armor. It should be further explored as an innovative approach to effectively protect against blast threats to civilian and military personnel. PMID:22745740
Galvanic Liquid Applied Coating System for Protection of Embedded Steel Surfaces from Corrosion
NASA Technical Reports Server (NTRS)
Curran, Joseph; MacDowell, Louis; Voska, N. (Technical Monitor)
2002-01-01
The corrosion of reinforcing steel in concrete is an insidious problem for the Kennedy Space Center, government agencies, and the general public. Existing corrosion protection systems on the market are costly, complex, and time-consuming to install, require continuous maintenance and monitoring, and require specialized skills for installation. NASA's galvanic liquid-applied coating offers companies the ability to conveniently protect embedded steel rebar surfaces from corrosion. Liquid-applied inorganic galvanic coating contains one ore more of the following metallic particles: magnesium, zinc, or indium and may contain moisture attracting compounds that facilitate the protection process. The coating is applied to the outer surface of reinforced concrete so that electrical current is established between metallic particles and surfaces of embedded steel rebar; and electric (ionic) current is responsible for providing the necessary cathodic protection for embedded rebar surfaces.
Planetary Protection Considerations for Life Support and Habitation Systems
NASA Technical Reports Server (NTRS)
Barta, Daniel J.; Hogan, John A.
2010-01-01
Life support systems for future human missions beyond low Earth orbit may include a combination of existing hardware components and advanced technologies. Discipline areas for technology development include atmosphere revitalization, water recovery, solid waste management, crew accommodations, food production, thermal systems, environmental monitoring, fire protection and radiation protection. Life support systems will be influenced by in situ resource utilization (ISRU), crew mobility and the degree of extravehicular activity. Planetary protection represents an additional set of requirements that technology developers have generally not considered. Planetary protection guidelines will affect the kind of operations, processes, and functions that can take place during future exploration missions, including venting and discharge of liquids and solids, ejection of wastes, use of ISRU, requirements for cabin atmospheric trace contaminant concentrations, cabin leakage and restrictions on what materials, organisms, and technologies that may be brought on missions. Compliance with planetary protection requirements may drive development of new capabilities or processes (e.g. in situ sterilization, waste containment, contaminant measurement) and limit or prohibit certain kinds of operations or processes (e.g. unfiltered venting). Ultimately, there will be an effect on mission costs, including the mission trade space. Planetary protection requirements need to be considered early in technology development programs. It is expected that planetary protection will have a major impact on technology selection for future missions.
Moreira, Fernando X; Silva, Renata; André, Maria B; de Pinho, Paula G; Bastos, Maria L; Ruivo, João; Ruivo, Patrícia; Carmo, Helena
2018-07-01
The use of performance enhancing drugs is not only common in humans, but also in animal sports, including racing of horses, greyhounds and pigeons. The development of accurate analytical procedures to detect doping agents in sports is crucial in order to protect the fair-play of the game, avoid financial fraud in the attribution of eventual awards and, even more important, to protect the animals from harmful drugs and/or dangerous dosage regimens. The present study aimed to develop and validate, a method that enabled the screening and confirmation of the presence of a beta-agonist (clenbuterol) and three corticosteroids (betamethasone, prednisolone and budesonide) in faeces from pigeons. The extraction procedure entailed the combination of liquid-liquid extraction with solid-phase extraction and the analysis was performed by liquid- chromatography coupled to tandem mass spectrometry, with a single 15 minute chromatographic run-time. The method was validated concerning selectivity, linearity (with coefficients of determination always >0.99), accuracy (87.5-114.9%), inter-day and intra-day precisions, limits of detection (0.14-1.81 ng/g) and limits of quantification (0.49-6.08 ng/g), stability and extraction recovery (71.0%-99.3%). The method was successfully applied for the analysis of samples from two pigeons that had been orally administered betamethasone, demonstrating its suitability for doping control purposes. Copyright © 2018. Published by Elsevier B.V.
2016-06-01
for several cyanobacteria (Hu et al. 2003) as well as for EPS in clay soil (Nugent et al. 2009). The adhesion, water retention, and protective...exopolymers on the liquid limit of clays and its engineering applications. Transportation Research Record: Journal of the Transportation Research...Development of progressive failure in sensitive clay slopes. Canadian Geotechnical Journal 49: 782-795. Rushing, J. F., and J. K. Newman., 2010
Entanglement in 3D Kitaev spin liquids
NASA Astrophysics Data System (ADS)
Matern, S.; Hermanns, M.
2018-06-01
Quantum spin liquids are highly fascinating quantum liquids in which the spin degrees of freedom fractionalize. An interesting class of spin liquids are the exactly solvable, three-dimensional Kitaev spin liquids. Their fractionalized excitations are Majonara fermions, which may exhibit a variety of topological band structures—ranging from topologically protected Weyl semi-metals over nodal semi-metals to systems with Majorana Fermi surfaces. We study the entanglement spectrum of such Kitaev spin liquids and verify that it is closely related to the topologically protected edge spectrum. Moreover, we find that in some cases the entanglement spectrum contains even more information about the topological features than the surface spectrum, and thus provides a simple and reliable tool to probe the topology of a system.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 25 2010-07-01 2010-07-01 false Standards: Pumps and valves in heavy liquid service, pressure relief devices in light liquid or heavy liquid service, and flanges and other... and valves in heavy liquid service, pressure relief devices in light liquid or heavy liquid service...
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 25 2010-07-01 2010-07-01 false Standards: Pumps and valves in heavy liquid service, pressure relief devices in light liquid or heavy liquid service, and flanges and other... heavy liquid service, pressure relief devices in light liquid or heavy liquid service, and flanges and...
Advanced worker protection system. Topical report, Phase I
DOE Office of Scientific and Technical Information (OSTI.GOV)
Myers, J.
1995-07-01
The Department of Energy (DOE) is in the process of defining the magnitude and diversity of Decontamination and Decommissioning (D&D) obligations at its numerous sites. The DOE believes that existing technologies are inadequate to solve many challenging problems such as how to decontaminate structures and equipment cost effectively, what to do with materials and wastes generated, and how to adequately protect workers and the environment. Preliminary estimates show a tremendous need for effective use of resources over a relatively long period (over 30 years). Several technologies are being investigated which can potentially reduce D&D costs while providing appropriate protection tomore » DOE workers. The DOE recognizes that traditional methods used by the EPA in hazardous waste site clean up activities are insufficient to provide the needed protection and worker productivity demanded by DOE D&D programs. As a consequence, new clothing and equipment which can adequately protect workers while providing increases in worker productivity are being sought for implementation at DOE sites. This project will result in the development of an Advanced Worker Protection System (AWPS). The AWPS will be built around a life support backpack that uses liquid air to provide cooling as well as breathing gas to the worker. The backpack will be combined with advanced protective garments, advanced liquid cooling garment, respirator, communications, and support equipment to provide improved worker protection, simplified system, maintenance, and dramatically improve worker productivity through longer duration work cycles.« less
Poliakova, V A; Suchko, V A; Tereshchenko, V P; Bazyka, D A; Golovnia, O M; Rudavskaia, G A
2001-01-01
Bronchial bioptates of 97 liquidators of the Chernobyl accident consequences with chronic bronchitis and 23 patients of control nosological group as well as sputum (174 persons) and BAL (22 persons) of liquidators with chronic obstructive lung disease (COLD) were studied to define pathogenic role of automicroflora in the development of lung diseases. Such methods as electron microscopy, immunohistochemistry and microbiology were used. The revealed invasion of microorganisms occurred against the background of pathology of superficial bronchial epithelium with a decrease of HLA-DR and CD23 lymphocytes and increase of CD1c lymphocytes in lamina propria of bronchial mucosa of the liquidators. Verification of microorganisms characteristic of the upper respiratory tracts and atypical presence of Escherichia coli were found in the contents of the lower parts of broncho-pulmonary system of the liquidators. The obtained results testify to the activation of automicroflora and appearance of pathogenic microorganisms were caused by deterioration of specific and non-specific immune protection in liquidators with COLD.
NOVEL STRATEGIES FOR THE SYNTHESIS OF IONIC LIQUIDS IN AN ENVIRONMENTALLY FRIENDLY MANNER
The collaborative research effort established between the U. S. Environmental Protection Agency (USEPA) and Kreido Laboratories has focused on the development of reaction strategies for the synthesis of chemicals and materials in a green and sustainable manner. One such area of ...
30 CFR 77.1103 - Flammable liquids; storage.
Code of Federal Regulations, 2013 CFR
2013-07-01
... drawn from storage shall be kept in properly identified safety cans. (b) Unburied flammable-liquid... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Flammable liquids; storage. 77.1103 Section 77... Fire Protection § 77.1103 Flammable liquids; storage. (a) Flammable liquids shall be stored in...
30 CFR 77.1103 - Flammable liquids; storage.
Code of Federal Regulations, 2011 CFR
2011-07-01
... drawn from storage shall be kept in properly identified safety cans. (b) Unburied flammable-liquid... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Flammable liquids; storage. 77.1103 Section 77... Fire Protection § 77.1103 Flammable liquids; storage. (a) Flammable liquids shall be stored in...
30 CFR 77.1103 - Flammable liquids; storage.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Flammable liquids; storage. 77.1103 Section 77... Fire Protection § 77.1103 Flammable liquids; storage. (a) Flammable liquids shall be stored in... drawn from storage shall be kept in properly identified safety cans. (b) Unburied flammable-liquid...
30 CFR 77.1103 - Flammable liquids; storage.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Flammable liquids; storage. 77.1103 Section 77... Fire Protection § 77.1103 Flammable liquids; storage. (a) Flammable liquids shall be stored in... drawn from storage shall be kept in properly identified safety cans. (b) Unburied flammable-liquid...
Engineering Field-Responsive Soft Materials for Protecting First Responders, Athletes and Astronauts
NASA Astrophysics Data System (ADS)
Wagner, Norman
I will show how we are using novel field-responsive polymeric materials as nanocomposites for enhanced ballistic and impact protection, puncture resistant medical gloves, energy absorbing materials for mitigating impacts and concussions, as well as in systems for mitigating micrometeoroid and orbital debris threats in space applications. New mechano-chemical force-responsive polymers will find use as self-healing protective materials. Hierarchically self-assembled block copolymers in ionic liquids form ions-elastomers with unique mechano-electrical response for use in flexible electronics and sensors. Illustrations of technological applications under commercial development will be discussed, including use in astronaut protection and possible application in the manned mission to Mars.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Standards: Pumps and valves in heavy liquid service, pressure relief devices in light liquid or heavy liquid service, and connectors. 60.482-8... Standards: Pumps and valves in heavy liquid service, pressure relief devices in light liquid or heavy liquid...
NASA Technical Reports Server (NTRS)
Leiser, Daniel B. (Inventor); Hsu, Ming-Ta S. (Inventor); Chen, Timothy S. (Inventor)
1999-01-01
Ceramics are protected from high temperature degradation, including high temperature, oxidative, aeroconvective degradation by a high temperature and oxidation resistant coating of a room temperature curing, hydrolyzed and partially condensed liquid polyorganosiloxane to the surface of the ceramic. The liquid polyorganosiloxane is formed by the hydrolysis and partial condensation of an alkyltrialkoxysilane with water or a mixture of an alkyltrialkoxysilane and a dialkyldialkoxysilane with water. The liquid polyorganosiloxane cures at room temperature on the surface of the ceramic to form a hard, protective, solid coating which forms a high temperature environment, and is also used as an adhesive for adhering a repair plug in major damage to the ceramic. This has been found useful for protecting and repairing porous, rigid ceramics of a type used on reentry space vehicles.
NASA Technical Reports Server (NTRS)
Mikes, F.
1984-01-01
Silane primers for use as thermal protection on external tanks were subjected to various analytic techniques to determine the most effective testing method for silane lot evaluation. The analytic methods included high performance liquid chromatography, gas chromatography, thermogravimetry (TGA), and fourier transform infrared spectroscopy (FTIR). It is suggested that FTIR be used as the method for silane lot evaluation. Chromatograms, TGA profiles, bar graphs showing IR absorbances, and FTIR spectra are presented.
Fire extinguishment and inhibition in spacecraft environments
NASA Technical Reports Server (NTRS)
Deris, John
1987-01-01
It was concluded that it is essential that NASA develop a comprehensive approach to fire extinguishment and inerting in spacecraft environments. Electronic equipment might be easily protected through use of an onboard inert gas generating system. The use of Halon 1301 presents serious technological challenges for agent cleanup and removal of the toxic and corrosive products of combustion. Nitrogen pressurization, while effective, probably presents a serious weight penality. The use of liquid water sprays appears to be the most effective approach to general purpose spacecraft fire protection.
Al-based anti-corrosion and T-permeation barrier development for future DEMO blankets
NASA Astrophysics Data System (ADS)
Krauss, W.; Konys, J.; Holstein, N.; Zimmermann, H.
2011-10-01
In the Helium-Cooled-Liquid-Lead (HCLL) design of Test-Blanket-Modules (TBM's) for a future fusion power plant Pb-15.7Li is used as liquid breeder which is in direct contact with the structure material, e.g. EUROFER steel. Compatibility testing showed that high corrosion attack appears and that the dissolved steel components form precipitates with a high risk of system blockages. A reliable operation needs coatings as corrosion barriers. The earlier developed Hot-Dip Aluminisation (HDA) process has shown that Al-based scales can act as anti-corrosion as well as T-permeation barriers. Meanwhile two advanced electro-chemically based processes for deposition of Al-scales were successfully developed. The first (ECA = Electro-Chemical Al-deposition) is working with an organic electrolyte and the second one (ECX = Electro-Chemical-X-metal-deposition) is based on ionic liquids. Coatings in the μm-range were deposited homogeneously with exact controllable thicknesses. Metallurgical investigations showed the successful generation of protective scales and compatibility testing demonstrated the barrier function.
21 CFR 880.5090 - Liquid bandage.
Code of Federal Regulations, 2013 CFR
2013-04-01
... powder and liquid combination used to cover an opening in the skin or as a dressing for burns. The device is also used as a topical skin protectant. (b) Classification. Class I (general controls). When used only as a skin protectant, the device is exempt from the premarket notification procedures in subpart E...
21 CFR 880.5090 - Liquid bandage.
Code of Federal Regulations, 2011 CFR
2011-04-01
... powder and liquid combination used to cover an opening in the skin or as a dressing for burns. The device is also used as a topical skin protectant. (b) Classification. Class I (general controls). When used only as a skin protectant, the device is exempt from the premarket notification procedures in subpart E...
21 CFR 880.5090 - Liquid bandage.
Code of Federal Regulations, 2014 CFR
2014-04-01
... powder and liquid combination used to cover an opening in the skin or as a dressing for burns. The device is also used as a topical skin protectant. (b) Classification. Class I (general controls). When used only as a skin protectant, the device is exempt from the premarket notification procedures in subpart E...
21 CFR 880.5090 - Liquid bandage.
Code of Federal Regulations, 2012 CFR
2012-04-01
... powder and liquid combination used to cover an opening in the skin or as a dressing for burns. The device is also used as a topical skin protectant. (b) Classification. Class I (general controls). When used only as a skin protectant, the device is exempt from the premarket notification procedures in subpart E...
21 CFR 880.5090 - Liquid bandage.
Code of Federal Regulations, 2010 CFR
2010-04-01
... powder and liquid combination used to cover an opening in the skin or as a dressing for burns. The device is also used as a topical skin protectant. (b) Classification. Class I (general controls). When used only as a skin protectant, the device is exempt from the premarket notification procedures in subpart E...
Zhuo, Limeng; Peng, Jingjing; Zhao, Yunli; Li, Dongxiang; Xie, Xiuman; Tong, Ling; Yu, Zhiguo
2017-10-01
Traditional Chinese medicine consists of complex phytochemical constituents. Selecting appropriate analytical markers of traditional Chinese medicine is a critical step in quality control. Currently, the combination of fingerprinting and efficacy evaluation is considered as a useful method for screening active ingredients in complex mixtures. This study was designed to develop an orthogonal partial least squares model for screening bioactive quality control markers of QishenYiqi dripping pills based on the fingerprint-efficacy relationship. First, the chemical fingerprints of 49 batches of QishenYiqi dripping pill samples were established by ultra-high performance liquid chromatography coupled with a photodiode array detector. Second, ultra-high performance liquid chromatography coupled with quadrupole-time-of-flight mass spectrometry was exploited to systematically investigate the 36 copossessing fingerprint components in QishenYiqi dripping pills. The vascular protective activity of QishenYiqi dripping pills was determined by using a cell counting kit-8 assay. Finally, fingerprint-efficacy relationship was established by orthogonal partial least squares model. The results indicated that ten components exhibited strong correlation with vascular protective activity, and these were preliminarily screened as quality control markers. The present study provided a novel idea for the study of the pharmacodynamic material basis and quality evaluation of QishenYiqi dripping pills. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
METHOD OF FORMING A PROTECTIVE COATING ON FERROUS METAL SURFACES
Schweitzer, D.G.; Weeks, J.R.; Kammerer, O.F.; Gurinsky, D.H.
1960-02-23
A method is described of protecting ferrous metal surfaces from corrosive attack by liquid metals, such as liquid bismuth or lead-bismuth alloys. The nitrogen content of the ferrous metal surface is first reduced by reacting the metal surface with a metal which forms a stable nitride. Thereafter, the surface is contacted with liquid metal containing at least 2 ppm zirconium at a temperature in the range of 550 to 1100 deg C to form an adherent zirconium carbide layer on the ferrous surface.
Johnson, Alexander; Brace, Christopher
2015-01-01
Interventional oncology procedures such as thermal ablation are becoming widely used for many tumours in the liver, kidney and lung. Thermal ablation refers to the focal destruction of tissue by generating cytotoxic temperatures in the treatment zone. Hydrodissection - separating tissues with fluids - protects healthy tissues adjacent to the ablation treatment zone to improve procedural safety, and facilitate more aggressive power application or applicator placement. However, fluids such as normal saline and 5% dextrose in water (D5W) can migrate into the peritoneum, reducing their protective efficacy. As an alternative, a thermo-gelable poloxamer 407 (P407) solution has been recently developed to facilitate hydrodissection procedures. We hypothesise that the P407 gel material does not provide convective heat dissipation from the ablation site, and therefore may alter the heat transfer dynamics compared to liquid materials during hydrodissection-assisted thermal ablation. The purpose of this study was to investigate the heat dissipation mechanics within D5W, liquid P407 and gel P407 hydrodissection barriers. Overall it was shown that the gel P407 dissipated heat primarily through conduction, whereas the liquid P407 and D5W dissipated heat through convection. Furthermore, the rate of temperature change within the gel P407 was greater than liquid P407 and D5W. Testing to evaluate the in vivo efficacy of the fluids with different modes of heat dissipation seems warranted for further study.
Cable Feedthrough Between Liquid Oxygen And Ambient
NASA Technical Reports Server (NTRS)
Myers, Don A.
1992-01-01
Encapsulant and back pressure provide double protection. Cable-feedthrough tube between ambient air and interior of vessel containing liquid oxygen protects external instrumentation and cable from oxygen. Cable in tube surrounded by potting compound. Provides flow of gaseous nitrogen to dilute oxidant and makes it harmless in case of leakage through crack in potting compound.
40 CFR 227.32 - Liquid, suspended particulate, and solid phases of a material.
Code of Federal Regulations, 2010 CFR
2010-07-01
... solid phases of a material. 227.32 Section 227.32 Protection of Environment ENVIRONMENTAL PROTECTION... MATERIALS Definitions § 227.32 Liquid, suspended particulate, and solid phases of a material. (a) For the... obtained above prior to centrifugation and filtration. The solid phase includes all material settling to...
40 CFR 227.32 - Liquid, suspended particulate, and solid phases of a material.
Code of Federal Regulations, 2011 CFR
2011-07-01
... solid phases of a material. 227.32 Section 227.32 Protection of Environment ENVIRONMENTAL PROTECTION... MATERIALS Definitions § 227.32 Liquid, suspended particulate, and solid phases of a material. (a) For the... obtained above prior to centrifugation and filtration. The solid phase includes all material settling to...
Fire and Ice - Safety, Comfort, and Getting the Firefighters' Job Done
NASA Technical Reports Server (NTRS)
Foley, Tico; Butzer, Melissa
1999-01-01
Daily life for firefighters consists of working with life-threatening hazards in hostile environments. A major hazard is excessive ambient heat. New hazards have arisen from protective gear that was intended to increase survival time of firefighters while finding and rescuing victims. The insulation is so good now that a firefighter's metabolic heat buildup cannot escape. This forces body core temperatures to life threatening levels in about 20 minutes of moderate activity. Using NASA space suit technology, Oceaneering Space Systems developed a liquid cooling garment prototype that will remove up to 250 watts of metabolic heat. After testing and certification as an approved accessory for firefighter use, this garment will be available for use by any individual encapsulated in protective clothing. This demonstration will present a high surface area circulated liquid cooling garment displayed on a mannequin and available for attendees to try on to experience the effects of active cooling.
Bhide, Yoshita; Tomar, Jasmine; Dong, Wei; de Vries-Idema, Jacqueline; Frijlink, Henderik W; Huckriede, Anke; Hinrichs, Wouter L J
2018-11-01
Administration of influenza vaccines to the lungs could be an attractive alternative to conventional parenteral administration. In this study, we investigated the deposition site of pulmonary delivered liquid and powder influenza vaccine formulations and its relation to their immunogenicity and protective efficacy. In vivo deposition studies in cotton rats revealed that, the powder formulation was mainly deposited in the trachea ( ∼ 65%) whereas the liquid was homogenously distributed throughout the lungs ( ∼ 96%). In addition, only 60% of the antigen in the powder formulation was deposited in the respiratory tract with respect to the liquid formulation. Immunogenicity studies showed that pulmonary delivered liquid and powder influenza formulations induced robust systemic and mucosal immune responses (significantly higher by liquids than by powders). When challenged with a clinical isolate of homologous H1N1pdm virus, all animals pulmonary administered with placebo had detectable virus in their lungs one day post challenge. In contrast, none of the vaccinated animals had detectable lung virus titers, except for two out of eight animals from the powder immunized group. Also, pulmonary vaccinated animals showed no or little signs of infection like increase in breathing frequency or weight loss upon challenge as compared to animals from the negative control group. In conclusion, immune responses induced by liquid formulation were significantly higher than responses induced by powder formulation, but the overall protective efficacy of both formulations was comparable. Thus, pulmonary immunization is capable of inducing protective immunity and the site of antigen deposition seems to be of minor relevance in inducing protection.
Damle, Viraj G; Tummala, Abhishiktha; Chandrashekar, Sriram; Kido, Cassidee; Roopesh, Ajay; Sun, Xiaoda; Doudrick, Kyle; Chinn, Jeff; Lee, James R; Burgin, Timothy P; Rykaczewski, Konrad
2015-02-25
The use of personal protective gear made from omniphobic materials that easily shed drops of all sizes could provide enhanced protection from direct exposure to most liquid-phase biological and chemical hazards and facilitate the postexposure decontamination of the gear. In recent literature, lubricated nanostructured fabrics are seen as attractive candidates for personal protective gear due to their omniphobic and self-healing characteristics. However, the ability of these lubricated fabrics to shed low surface tension liquids after physical contact with other objects in the surrounding, which is critical in demanding healthcare and military field operations, has not been investigated. In this work, we investigate the depletion of oil from lubricated fabrics in contact with highly absorbing porous media and the resulting changes in the wetting characteristics of the fabrics by representative low and high surface tension liquids. In particular, we quantify the loss of the lubricant and the dynamic contact angles of water and ethanol on lubricated fabrics upon repeated pressurized contact with highly absorbent cellulose-fiber wipes at different time intervals. We demonstrate that, in contrast to hydrophobic nanoparticle coated microfibers, fabrics encapsulated within a polymer that swells with the lubricant retain the majority of the oil and are capable of repelling high as well as low surface tension liquids even upon multiple contacts with the highly absorbing wipes. The fabric supported lubricant-swollen polymeric films introduced here, therefore, could provide durable and easy to decontaminate protection against hazardous biological and chemical liquids.
40 CFR 417.160 - Applicability; description of the manufacture of liquid detergents subcategory.
Code of Federal Regulations, 2010 CFR
2010-07-01
... manufacture of liquid detergents subcategory. 417.160 Section 417.160 Protection of Environment ENVIRONMENTAL... CATEGORY Manufacture of Liquid Detergents Subcategory § 417.160 Applicability; description of the manufacture of liquid detergents subcategory. The provisions of this subpart are applicable to discharges...
DOE Office of Scientific and Technical Information (OSTI.GOV)
CORBETT JE; TEDESCH AR; WILSON RA
2011-02-14
A modular, transportable evaporator system, using thin film evaporative technology, is planned for deployment at the Hanford radioactive waste storage tank complex. This technology, herein referred to as a wiped film evaporator (WFE), will be located at grade level above an underground storage tank to receive pumped liquids, concentrate the liquid stream from 1.1 specific gravity to approximately 1.4 and then return the concentrated solution back into the tank. Water is removed by evaporation at an internal heated drum surface exposed to high vacuum. The condensed water stream will be shipped to the site effluent treatment facility for final disposal.more » This operation provides significant risk mitigation to failure of the aging 242-A Evaporator facility; the only operating evaporative system at Hanford maximizing waste storage. This technology is being implemented through a development and deployment project by the tank farm operating contractor, Washington River Protection Solutions (WRPS), for the Office of River Protection/Department of Energy (ORPIDOE), through Columbia Energy and Environmental Services, Inc. (Columbia Energy). The project will finalize technology maturity and install a system at one of the double-shell tank farms. This paper summarizes results of a pilot-scale test program conducted during calendar year 2010 as part of the ongoing technology maturation development scope for the WFE.« less
Compressed Natural Gas Vehicle Maintenance Facility Modification Handbook
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kelly, Kay L.; Ramsden, Margo M.; Gonzales, John E.
To ensure the safety of personnel and facilities, vehicle maintenance facilities are required by law and by guidelines of the National Fire Protection Association (NFPA) and the International Fire Code (IFC) to exhibit certain design features. They are also required to be fitted with certain fire protection equipment and devices because of the potential for fire or explosion in the event of fuel leakage or spills. All fuels have an explosion or fire potential if specific conditions are present. The hazard presented by liquid fuels, such as gasoline and diesel, results from the spillage of these liquids and subsequent ignitionmore » of vapors, causing a fire or explosion. Facilities that maintain liquid-fueled vehicles and implement appropriate safety measures are protected with ventilation systems designed to capture liquid fuel vapors at or near floor level. To minimize the potential for ignition in the event of a spill, receptacles, electrical fixtures, and hot-work operations, such as welding, are located outside of these areas. Compressed natural gas (CNG) is composed of methane with slight amounts of heavier simple hydrocarbons. Maintenance facilities that maintain CNG vehicles indoors must be protected against fire and explosion. However, the means of ensuring safety are different from those employed for liquid fuels because of the gaseous nature of methane and the fact that it is lighter than air. Because CNG is lighter than air, a release will rise to the ceiling of the maintenance facility and quickly dissipate rather than remaining at or near floor level like liquid fuel vapors. Although some of the means of protection for CNG vehicle maintenance facilities are similar to those used for liquid-fueled vehicles (ventilation and elimination of ignition sources), the types and placement of the protection equipment are different because of the behavior of the different fuels. The nature of gaseous methane may also require additional safeguards, such as combustible gas detectors and control systems, or specialized space heating, which are not needed in facilities servicing liquid-fuel vehicles. This handbook covers maintenance facilities that service CNG-fueled vehicles. Although similar requirements are mandated for liquefied natural gas (LNG) or liquefied petroleum gas (LPG) fueled vehicles, LNG and LPG are not covered in this handbook.« less
Study of thermal insulation for airborne liquid hydrogen fuel tanks
NASA Technical Reports Server (NTRS)
Ruccia, F. E.; Lindstrom, R. S.; Lucas, R. M.
1978-01-01
A concept for a fail-safe thermal protection system was developed. From screening tests, approximately 30 foams, adhesives, and reinforcing fibers using 0.3-meter square liquid nitrogen cold plate, CPR 452 and Stafoam AA1602, both reinforced with 10 percent by weight of 1/16 inch milled OCF Style 701 Fiberglas, were selected for further tests. Cyclic tests with these materials in 2-inch thicknesses bonded on a 0.6-meter square cold plate with Crest 7410 adhesive systems, were successful. Zero permeability gas barriers were identified and found to be compatible with the insulating concept.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Geothermal Development Associates; Don Michels Associates
1999-07-01
This program was instituted to quantify certain aspects of silica scaling deposition processes at the Miravalles Geothermal Field, Costa Rica. The program objective was to identify the highest temperature at which silica scale will develop from partially evaporated and significantly cooled geothermal liquid under operating conditions. Integral to the study objective was the quantification of certain aspects of silica deposition processes at the Miravalles Geothermal Field, Costa Rica. There, the objective was to reduce the scaling risk associated with adding a bottoming-cycle to generate more electricity from the liquids already being produced.
Mechanism of wear and tribofilm formation with ionic liquids and ashless antiwear additives
NASA Astrophysics Data System (ADS)
Sharma, Vibhu
Increasingly stringent government regulation on emissions (EPA Emissions Standard Reference Guide and latest CAFE standards requiring an average fuel economy of 54.5 mpg (combined cars and trucks) by 2025) impose significant challenges to the automotive and lubricant industries calling for the development and implementation of lower viscosity ILSAC GF-5&6 and API-CJ4&5 oils which further limit the amount of SAPS and deposits in engines. Development of additives that result in lower ash content, volatility and anti-wear property plays a crucial role in being able to reach these standards. The current industrial additive technology i.e. zinc dialkyldithiophosphate (ZDDP) forms harmful deposits on catalytic convertor due to the volatility of Zn, S and P which, impairs its functionality and consequently results in higher emission from vehicles. In this research work, ionic liquids (IL's) that are non-volatile have been studied as new generation environment friendly antiwear additives along with other ashless anti-wear additives including boron based additives to overcome the current challenges of improving the fuel efficiency and reducing the amount of hazardous emissions. The goal of this thesis work is to study the tribological performance of selected IL's and develop a comprehensive understating of IL's chemistry and its consequences to their friction and wear outcomes. As first approach, various P, S and F based ionic liquids are studied for their tribological properties by analyzing the friction and wear results generated using standard tribological experiments. Following this, advanced surface characterization techniques such as X-ray absorption near edge structure (XANES) spectroscopy, SEM, Nano-indentation, SPM techniques are used to investigate the chemical-mechanical properties of the antiwear films. Results indicate that the tribological properties of ionic liquids depend on their solubility in base oil (BO) as well as their chemical interaction with the rubbing surfaces. To address the solubility issue of IL's in BO, ILs with longer alkyl chain structure were carefully selected which helped enhance the van der waals interaction between strongly polar ILs and non-polar base oil. The interaction of IL's with the metal surfaces was examined by analyzing the chemical-mechanical properties of the antiwear films formed. Results indicate that ionic liquids do react with the steel surfaces and form a protective antiwear film composed of iron polyphosphates i.e. short to medium chain length which results in improved wear protection. In addition, soluble boron additive (SB) chemistries were blended with ionic liquids to study the synergism between these two ashless antiwear chemistries. Addition of soluble boron additive (SB) to phosphorous based IL (P_DEHP) reduces the incubation time for antiwear film formation by forming boron oxide/boron phosphate film as early as the rubbing starts and subsequently a more durable iron phosphate film is formed providing long lasting wear protection. The synergistic interaction of boron chemistry with phosphorous based ionic liquids provides superior antiwear properties while eliminating volatile elements such as Zn and S from the additive technology.
Carol-Visser, Jeroen; van der Schans, Marcel; Fidder, Alex; Hulst, Albert G; van Baar, Ben L M; Irth, Hubertus; Noort, Daan
2008-07-01
Rapid monitoring and retrospective verification are key issues in protection against and non-proliferation of chemical warfare agents (CWA). Such monitoring and verification are adequately accomplished by the analysis of persistent protein adducts of these agents. Liquid chromatography-mass spectrometry (LC-MS) is the tool of choice in the analysis of such protein adducts, but the overall experimental procedure is quite elaborate. Therefore, an automated on-line pepsin digestion-LC-MS configuration has been developed for the rapid determination of CWA protein adducts. The utility of this configuration is demonstrated by the analysis of specific adducts of sarin and sulfur mustard to human butyryl cholinesterase and human serum albumin, respectively.
Saraji, Mohammad; Ghambari, Hoda
2018-06-21
In this work we seek clues to select the appropriate dispersive liquid-liquid microextraction mode for extracting three categories of compounds. For this purpose, three common dispersive liquid-liquid microextraction modes were compared under optimized conditions. Traditional dispersive liquid-liquid microextraction, in situ ionic liquid dispersive liquid-liquid microextraction and conventional ionic liquid dispersive liquid-liquid microextraction using chloroform, 1-butyl-3-methylimidazolium tetrafluoroborate, and 1-hexyl-3-methylimidazolium hexafluorophosphate as the extraction solvent, respectively, were considered in this work. Phenolic, neutral aromatic and amino compounds (each category included six members) were studied as analytes. The analytes in the extracts were determined by high-performance liquid chromatography with UV detection. For the analytes with polar functionalities, the in situ ionic liquid dispersive liquid-liquid microextraction mode mostly led to better results. In contrast, for neutral hydrocarbons without polar functionalities, traditional dispersive liquid-liquid microextraction using chloroform produced better results. In this case, where dispersion forces were the dominant interactions in the extraction, the refractive index of solvent and analyte predicted the extraction performance better than the octanol-water partition coefficient. It was also revealed that none of the methods were successful in extracting very hydrophilic analytes (compounds with the log octanol-water partition coefficient < 2). The results of this study could be helpful in selecting a dispersive liquid-liquid microextraction mode for the extraction of various groups of compounds. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Thermodynamic processes associated with frostbite in the handling of liquid nitrogen
NASA Astrophysics Data System (ADS)
Johnson, W. L.; Cook, C. R.
2014-01-01
It is often taught that exposure to liquid nitrogen will cause frostbite or more severe damage to exposed skin tissue. However, it is also demonstrated that a full hand can be briefly immersed in liquid nitrogen without damage. To better understand and possibly visualize the effects of human tissue exposure to liquid nitrogen, a series of tests were conducted using simulated hands and arms composed of molded gelatin forms. The simulated hands and arms were immersed, sprayed, or splashed with liquid nitrogen both with and without state of the art personal protective equipment. Thermocouples were located within the test articles to allow for thermal mapping during the freezing process. The study is aimed to help understand frostbite hazards and the time constants involved with the handling of liquid nitrogen to improve future safety protocols for the safe handling of cryogenic fluids. Results of the testing also show the limits to handling liquid nitrogen while using various means of protection.
Fast Conversion of Ionic Liquids and Poly(Ionic Liquid)s into Porous Nitrogen-Doped Carbons in Air
Men, Yongjun; Ambrogi, Martina; Han, Baohang; Yuan, Jiayin
2016-01-01
Ionic liquids and poly(ionic liquid)s have been successfully converted into nitrogen-doped porous carbons with tunable surface area up to 1200 m2/g at high temperatures in air. Compared to conventional carbonization process conducted under inert gas to produce nitrogen-doped carbons, the new production method was completed in a rather shorter time without noble gas protection. PMID:27070588
Fast Conversion of Ionic Liquids and Poly(Ionic Liquid)s into Porous Nitrogen-Doped Carbons in Air.
Men, Yongjun; Ambrogi, Martina; Han, Baohang; Yuan, Jiayin
2016-04-08
Ionic liquids and poly(ionic liquid)s have been successfully converted into nitrogen-doped porous carbons with tunable surface area up to 1200 m²/g at high temperatures in air. Compared to conventional carbonization process conducted under inert gas to produce nitrogen-doped carbons, the new production method was completed in a rather shorter time without noble gas protection.
Upgrade plans for the ATLAS Forward Calorimeter at the HL-LHC
NASA Astrophysics Data System (ADS)
Rutherfoord, John; ATLAS Liquid Argon Calorimeter Group
2012-12-01
Although data-taking at CERN's Large Hadron Collider (LHC) is expected to continue for a number of years, plans are already being developed for operation of the LHC and associated detectors at an increased instantaneous luminosity about 5 times the original design value of 1034 cm-2 s-1. The increased particle flux at this high luminosity (HL) will have an impact on many sub-systems of the ATLAS detector. In particular, in the liquid argon forward calorimeter (FCal), which was designed for operation at LHC luminosities, the associated increase in the ionization load at HL-LHC luminosities creates a number of problems which can degrade its performance. These include space-charge effects in the liquid argon gaps, excessive drop in potential across the gaps due to large HV supply currents through the protection resistors, and an increase in temperature which may cause the liquid argon to boil. One solution, which would require opening both End-Cap cryostats, is the construction and installation of new FCals with narrower liquid argon gaps, lowering the values of the protection resistors, and the addition of cooling loops. A second proposed solution, which does not require opening the cryostat cold volume, is the addition of a small, warm calorimeter in front of each existing FCal, resulting in a reduction of the particle flux to levels at which the existing FCal can operate normally.
40 CFR 264.1052 - Standards: Pumps in light liquid service.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 26 2014-07-01 2014-07-01 false Standards: Pumps in light liquid... DISPOSAL FACILITIES Air Emission Standards for Equipment Leaks § 264.1052 Standards: Pumps in light liquid service. (a)(1) Each pump in light liquid service shall be monitored monthly to detect leaks by the...
40 CFR 60.482-2a - Standards: Pumps in light liquid service.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 7 2013-07-01 2013-07-01 false Standards: Pumps in light liquid... Construction, Reconstruction, or Modification Commenced After November 7, 2006 § 60.482-2a Standards: Pumps in light liquid service. (a)(1) Each pump in light liquid service shall be monitored monthly to detect...
40 CFR 60.482-2a - Standards: Pumps in light liquid service.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 7 2014-07-01 2014-07-01 false Standards: Pumps in light liquid... Construction, Reconstruction, or Modification Commenced After November 7, 2006 § 60.482-2a Standards: Pumps in light liquid service. (a)(1) Each pump in light liquid service shall be monitored monthly to detect...
40 CFR 60.482-2a - Standards: Pumps in light liquid service.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 7 2012-07-01 2012-07-01 false Standards: Pumps in light liquid... Construction, Reconstruction, or Modification Commenced After November 7, 2006 § 60.482-2a Standards: Pumps in light liquid service. (a)(1) Each pump in light liquid service shall be monitored monthly to detect...
40 CFR 264.1052 - Standards: Pumps in light liquid service.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 26 2011-07-01 2011-07-01 false Standards: Pumps in light liquid... DISPOSAL FACILITIES Air Emission Standards for Equipment Leaks § 264.1052 Standards: Pumps in light liquid service. (a)(1) Each pump in light liquid service shall be monitored monthly to detect leaks by the...
40 CFR 264.1052 - Standards: Pumps in light liquid service.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 27 2013-07-01 2013-07-01 false Standards: Pumps in light liquid... DISPOSAL FACILITIES Air Emission Standards for Equipment Leaks § 264.1052 Standards: Pumps in light liquid service. (a)(1) Each pump in light liquid service shall be monitored monthly to detect leaks by the...
40 CFR 265.1052 - Standards: Pumps in light liquid service.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 26 2011-07-01 2011-07-01 false Standards: Pumps in light liquid..., STORAGE, AND DISPOSAL FACILITIES Air Emission Standards for Equipment Leaks § 265.1052 Standards: Pumps in light liquid service. (a)(1) Each pump in light liquid service shall be monitored monthly to detect...
40 CFR 265.1052 - Standards: Pumps in light liquid service.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 27 2013-07-01 2013-07-01 false Standards: Pumps in light liquid..., STORAGE, AND DISPOSAL FACILITIES Air Emission Standards for Equipment Leaks § 265.1052 Standards: Pumps in light liquid service. (a)(1) Each pump in light liquid service shall be monitored monthly to detect...
40 CFR 265.1052 - Standards: Pumps in light liquid service.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 27 2012-07-01 2012-07-01 false Standards: Pumps in light liquid..., STORAGE, AND DISPOSAL FACILITIES Air Emission Standards for Equipment Leaks § 265.1052 Standards: Pumps in light liquid service. (a)(1) Each pump in light liquid service shall be monitored monthly to detect...
40 CFR 264.1052 - Standards: Pumps in light liquid service.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 27 2012-07-01 2012-07-01 false Standards: Pumps in light liquid... DISPOSAL FACILITIES Air Emission Standards for Equipment Leaks § 264.1052 Standards: Pumps in light liquid service. (a)(1) Each pump in light liquid service shall be monitored monthly to detect leaks by the...
40 CFR 265.1052 - Standards: Pumps in light liquid service.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 26 2014-07-01 2014-07-01 false Standards: Pumps in light liquid..., STORAGE, AND DISPOSAL FACILITIES Air Emission Standards for Equipment Leaks § 265.1052 Standards: Pumps in light liquid service. (a)(1) Each pump in light liquid service shall be monitored monthly to detect...
49 CFR 179.400-19 - Valves and gages.
Code of Federal Regulations, 2014 CFR
2014-10-01
... control of vapor phase pressure, vapor phase venting, liquid transfer and liquid flow rates. All valves... within suitable protective housings. A liquid level gage and a vapor phase pressure gage must be provided... Liquid Tank Car Tanks and Seamless Steel Tanks (Classes DOT-113 and 107A) § 179.400-19 Valves and gages...
49 CFR 179.400-19 - Valves and gages.
Code of Federal Regulations, 2012 CFR
2012-10-01
... control of vapor phase pressure, vapor phase venting, liquid transfer and liquid flow rates. All valves... within suitable protective housings. A liquid level gage and a vapor phase pressure gage must be provided... Liquid Tank Car Tanks and Seamless Steel Tanks (Classes DOT-113 and 107A) § 179.400-19 Valves and gages...
49 CFR 179.400-19 - Valves and gages.
Code of Federal Regulations, 2013 CFR
2013-10-01
... control of vapor phase pressure, vapor phase venting, liquid transfer and liquid flow rates. All valves... within suitable protective housings. A liquid level gage and a vapor phase pressure gage must be provided... Liquid Tank Car Tanks and Seamless Steel Tanks (Classes DOT-113 and 107A) § 179.400-19 Valves and gages...
40 CFR 799.2155 - Commercial hexane.
Code of Federal Regulations, 2013 CFR
2013-07-01
... least 40 liquid volume percent n-hexane (CAS No. 110-54-3) and at least 5 liquid volume percent... contains at least 40 liquid volume percent but no more than 55 liquid volume percent n-hexane and no less... 40 Protection of Environment 33 2013-07-01 2013-07-01 false Commercial hexane. 799.2155 Section...
40 CFR 799.2155 - Commercial hexane.
Code of Federal Regulations, 2014 CFR
2014-07-01
... least 40 liquid volume percent n-hexane (CAS No. 110-54-3) and at least 5 liquid volume percent... contains at least 40 liquid volume percent but no more than 55 liquid volume percent n-hexane and no less... 40 Protection of Environment 32 2014-07-01 2014-07-01 false Commercial hexane. 799.2155 Section...
40 CFR 761.269 - Sampling liquid PCB remediation waste.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Sampling liquid PCB remediation waste..., AND USE PROHIBITIONS Cleanup Site Characterization Sampling for PCB Remediation Waste in Accordance with § 761.61(a)(2) § 761.269 Sampling liquid PCB remediation waste. (a) If the liquid is single phase...
Fast breeder reactor protection system
van Erp, J.B.
1973-10-01
Reactor protection is provided for a liquid-metal-fast breeder reactor core by measuring the coolant outflow temperature from each of the subassemblies of the core. The outputs of the temperature sensors from a subassembly region of the core containing a plurality of subassemblies are combined in a logic circuit which develops a scram alarm if a predetermined number of the sensors indicate an over temperature condition. The coolant outflow from a single subassembly can be mixed with the coolant outflow from adjacent subassemblies prior to the temperature sensing to increase the sensitivity of the protection system to a single subassembly failure. Coherence between the sensors can be required to discriminate against noise signals. (Official Gazette)
[Medical protection during radiation accidents: some results and lessons of the Chernobyl accident].
Legeza, V I; Grebeniuk, A N; Zatsepin, V V
2011-01-01
Actions of medical radiation protection of liquidators of consequences of on Chernobyl atomic power station accident are analysed. It is shown, that during the early period of the accident medical protection of liquidators was provided by administration of radioprotectors, means of prophylaxis: of radioactive iodine incorporation and agent for preventing psychological and emotional stress. When carrying out decontamination and regenerative works, preparations which action is caused by increase of nonspecific resistance of an organism were applied. The lessons taken from the results of the Chernobyl accident, have allowed one to improve the system of medical protection and to introduce in practice new highly effective radioprotective agents.
Biocide squirting from an elastomeric tri-layer film.
Sonntag, Philippe; Hoerner, Pierre; Cheymol, André; Argy, Gilles; Riess, Gérard; Reiter, Günter
2004-05-01
Protective layers typically act in a passive way by simply separating two sides. Protection is only efficient as long as the layers are intact. If a high level of protection has to be achieved by thin layers, complementary measures need to be in place to ensure safety, even after breakage of the layer-an important issue in medical applications. Here, we present a novel approach for integrating a biocide liquid into a protective film (about 300-500 microm thick), which guarantees that a sufficient amount of biocide is rapidly released when the film is punctured. The film is composed of a middle layer, containing the liquid in droplet-like compartments, sandwiched between two elastomeric boundary layers. When the film is punctured, the liquid squirts out of the middle layer. A theoretical model was used to determine the size and density of droplets that are necessary to ensure a sufficient quantity of biocide is expelled from an adequately elastic matrix to provide protection at the site of damage. We demonstrate the utility of this approach for the fabrication of surgical gloves.
Lunar Transportation Facilities and Operations Study, option 1
NASA Astrophysics Data System (ADS)
1991-05-01
Throughout the Option I period of the Lunar Transportation Facilities and Operations Study (LTFOS), McDonnell Douglas Space Systems Company - Kennedy Space Center (MDSSC-KSC) provided support to both the Planetary Surface Systems (PSS) Office at the National Aeronautics and Space Administration (NASA) at the Johnson Space Center and to the Flight and Ground Systems Projects Office (Payload Projects Management) at the Kennedy Space Center. The primary objective of the Option I phase of the study was to assist the above NASA centers in developing Space Exploration Initiative (SEI) concepts. MDSSC-KSC conducted three analyses which provided launch and landing detail to the proposed exploration concepts. One analysis, the Lunar Ejecta Assessment, was conducted to determine the effects of launch and landing a vehicle in a dusty environment. A second analysis, the Thermal/Micrometeoroid Protection Trade Study, was refined to determine the impacts that Reference Architecture Option 5A would have on thermal/micrometeoroid protection approaches. The third analysis, the Centaur Prelaunch Procedure Analysis, used a Centaur prelaunch test and checkout flow to identify key considerations that would be important if a Lunar Excursion Vehicle (LEV) was to use an expander cycle liquid oxygen-liquid hydrogen engine. Several 'quick look' assessments were also conducted. One quick look assessment, the Storable Propellant Quick Look Assessment, was conducted to identify design considerations that should be made if storable propellants were to be used instead of liquid oxygen and liquid hydrogen. The LEV Servicer Maintenance Analysis provided an early look at the effort required to maintain an LEV Servicer on the lunar surface. Also, support was provided to the PSS Logistics Manager to develop initial LEV Servicer cost inputs. Consideration was given to the advanced development that must be provided to accomplish a lunar and/or Mars mission. MDSS-KSC also provided support to both MASE and PSS by reviewing and commenting on architecture documents and concept definitions to ensure adequate considerations were given to the launch and landing function of an exploration initiative.
Lunar Transportation Facilities and Operations Study, option 1
NASA Technical Reports Server (NTRS)
1991-01-01
Throughout the Option I period of the Lunar Transportation Facilities and Operations Study (LTFOS), McDonnell Douglas Space Systems Company - Kennedy Space Center (MDSSC-KSC) provided support to both the Planetary Surface Systems (PSS) Office at the National Aeronautics and Space Administration (NASA) at the Johnson Space Center and to the Flight and Ground Systems Projects Office (Payload Projects Management) at the Kennedy Space Center. The primary objective of the Option I phase of the study was to assist the above NASA centers in developing Space Exploration Initiative (SEI) concepts. MDSSC-KSC conducted three analyses which provided launch and landing detail to the proposed exploration concepts. One analysis, the Lunar Ejecta Assessment, was conducted to determine the effects of launch and landing a vehicle in a dusty environment. A second analysis, the Thermal/Micrometeoroid Protection Trade Study, was refined to determine the impacts that Reference Architecture Option 5A would have on thermal/micrometeoroid protection approaches. The third analysis, the Centaur Prelaunch Procedure Analysis, used a Centaur prelaunch test and checkout flow to identify key considerations that would be important if a Lunar Excursion Vehicle (LEV) was to use an expander cycle liquid oxygen-liquid hydrogen engine. Several 'quick look' assessments were also conducted. One quick look assessment, the Storable Propellant Quick Look Assessment, was conducted to identify design considerations that should be made if storable propellants were to be used instead of liquid oxygen and liquid hydrogen. The LEV Servicer Maintenance Analysis provided an early look at the effort required to maintain an LEV Servicer on the lunar surface. Also, support was provided to the PSS Logistics Manager to develop initial LEV Servicer cost inputs. Consideration was given to the advanced development that must be provided to accomplish a lunar and/or Mars mission. MDSS-KSC also provided support to both MASE and PSS by reviewing and commenting on architecture documents and concept definitions to ensure adequate considerations were given to the launch and landing function of an exploration initiative.
12 CFR 370.11 - Enforcement mechanisms.
Code of Federal Regulations, 2010 CFR
2010-01-01
... TEMPORARY LIQUIDITY GUARANTEE PROGRAM § 370.11 Enforcement mechanisms. (a) Termination of Participation. If... participate in the temporary liquidity guarantee program, the FDIC will inform the entity that it will no longer be provided the protections of the temporary liquidity guarantee program. (1) Termination of...
Solar converter system with thermal overload protection
DOE Office of Scientific and Technical Information (OSTI.GOV)
Popovich, J.M.; Thornbury, T.R.
1979-10-02
A solar energy conversion system comprises: (a) a solar converter in which liquid absorbs solar radiation, the liquid being solar energy absorptive; (b) first means to circulate said liquid for flow through the converter; and (c) means to effect removal of liquid from the converter in response to an undesirable operation condition in said system. 12 claims.
Code of Federal Regulations, 2012 CFR
2012-07-01
... standards apply if liquids will be in my containment building? 267.1103 Section 267.1103 Protection of....1103 What additional design and operating standards apply if liquids will be in my containment building? If your containment building will be used to manage hazardous wastes containing free liquids or...
Regulatory Disruption and Arbitrage in Health-Care Data Protection.
Terry, Nicolas P
This article explains how the structure of U.S. health-care data protection (specifically its sectoral and downstream properties) has led to a chronically uneven policy environment for different types of health-care data. It examines claims for health-care data protection exceptionalism and competing demands such as data liquidity. In conclusion, the article takes the position that healthcare- data exceptionalism remains a valid imperative and that even current concerns about data liquidity can be accommodated in an exceptional protective model. However, re-calibrating our protection of health-care data residing outside of the traditional health-care domain is challenging, currently even politically impossible. Notwithstanding, a hybrid model is envisioned with downstream HIPAA model remaining the dominant force within the health-care domain, but being supplemented by targeted upstream and point-of-use protections applying to health-care data in disrupted spaces.
Method for improving the durability of ion insertion materials
Lee, Se-Hee; Tracy, C. Edwin; Cheong, Hyeonsik M.
2002-01-01
The invention provides a method of protecting an ion insertion material from the degradative effects of a liquid or gel-type electrolyte material by disposing a protective, solid ion conducting, electrically insulating, layer between the ion insertion layer and the liquid or gel-type electrolyte material. The invention further provides liquid or gel-type electrochemical cells having improved durability having a pair of electrodes, a pair of ion insertion layers sandwiched between the pair of electrodes, a pair of solid ion conducting layers sandwiched between the ion insertion layers, and a liquid or gel-type electrolyte material disposed between the solid ion conducting layers, where the solid ion conducting layer minimizes or prevents degradation of the faces of the ion insertion materials facing the liquid or gel-type electrolyte material. Electrochemical cells of this invention having increased durability include secondary lithium batteries and electrochromic devices.
NASA Technical Reports Server (NTRS)
Sauer, Richard; Rutz, Jeffrey; Schultz, John
2005-01-01
A solid-phase extraction (SPE) process has been developed for removing alcohols, carboxylic acids, aldehydes, ketones, amines, and other polar organic compounds from water. This process can be either a subprocess of a water-reclamation process or a means of extracting organic compounds from water samples for gas-chromatographic analysis. This SPE process is an attractive alternative to an Environmental Protection Administration liquid-liquid extraction process that generates some pollution and does not work in a microgravitational environment. In this SPE process, one forces a water sample through a resin bed by use of positive pressure on the upstream side and/or suction on the downstream side, thereby causing organic compounds from the water to be adsorbed onto the resin. If gas-chromatographic analysis is to be done, the resin is dried by use of a suitable gas, then the adsorbed compounds are extracted from the resin by use of a solvent. Unlike the liquid-liquid process, the SPE process works in both microgravity and Earth gravity. In comparison with the liquid-liquid process, the SPE process is more efficient, extracts a wider range of organic compounds, generates less pollution, and costs less.
Liquid secondary waste. Waste form formulation and qualification
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cozzi, A. D.; Dixon, K. L.; Hill, K. A.
The Hanford Site Effluent Treatment Facility (ETF) currently treats aqueous waste streams generated during Site cleanup activities. When the Hanford Tank Waste Treatment and Immobilization Plant (WTP) begins operations, a liquid secondary waste (LSW) stream from the WTP will need to be treated. The volume of effluent for treatment at the ETF will increase significantly. Washington River Protection Solutions is implementing a Secondary Liquid Waste Immobilization Technology Development Plan to address the technology needs for a waste form and solidification process to treat the increased volume of waste planned for disposal at the Integrated Disposal Facility IDF). Waste form testingmore » to support this plan is composed of work in the near term to demonstrate the waste form will provide data as input to a performance assessment (PA) for Hanford’s IDF.« less
The U.S. Environmental Protection Agency established the Environmental Technology Verification Program to accelerate the development and commercialization of improved environmental technology through third party verification and reporting of product performance. Research Triangl...
40 CFR 60.482-2 - Standards: Pumps in light liquid service.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 7 2014-07-01 2014-07-01 false Standards: Pumps in light liquid..., 2006 § 60.482-2 Standards: Pumps in light liquid service. (a)(1) Each pump in light liquid service... in § 60.482-1(c) and (f) and paragraphs (d), (e), and (f) of this section. A pump that begins...
40 CFR 60.482-2 - Standards: Pumps in light liquid service.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 7 2012-07-01 2012-07-01 false Standards: Pumps in light liquid..., 2006 § 60.482-2 Standards: Pumps in light liquid service. (a)(1) Each pump in light liquid service... in § 60.482-1(c) and (f) and paragraphs (d), (e), and (f) of this section. A pump that begins...
40 CFR 60.482-2 - Standards: Pumps in light liquid service.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 7 2013-07-01 2013-07-01 false Standards: Pumps in light liquid..., 2006 § 60.482-2 Standards: Pumps in light liquid service. (a)(1) Each pump in light liquid service... in § 60.482-1(c) and (f) and paragraphs (d), (e), and (f) of this section. A pump that begins...
Code of Federal Regulations, 2014 CFR
2014-07-01
... limitation: Connectors in gas/vapor service and light liquid service. 63.649 Section 63.649 Protection of...: Connectors in gas/vapor service and light liquid service. (a) If an owner or operator elects to monitor... gas/vapor service and for connectors in light liquid service. The data for the two groups of...
Code of Federal Regulations, 2013 CFR
2013-07-01
... limitation: Connectors in gas/vapor service and light liquid service. 63.649 Section 63.649 Protection of...: Connectors in gas/vapor service and light liquid service. (a) If an owner or operator elects to monitor... gas/vapor service and for connectors in light liquid service. The data for the two groups of...
Code of Federal Regulations, 2012 CFR
2012-07-01
... limitation: Connectors in gas/vapor service and light liquid service. 63.649 Section 63.649 Protection of...: Connectors in gas/vapor service and light liquid service. (a) If an owner or operator elects to monitor... gas/vapor service and for connectors in light liquid service. The data for the two groups of...
Code of Federal Regulations, 2010 CFR
2010-07-01
... limitation: Connectors in gas/vapor service and light liquid service. 63.649 Section 63.649 Protection of...: Connectors in gas/vapor service and light liquid service. (a) If an owner or operator elects to monitor... gas/vapor service and for connectors in light liquid service. The data for the two groups of...
Code of Federal Regulations, 2011 CFR
2011-07-01
... limitation: Connectors in gas/vapor service and light liquid service. 63.649 Section 63.649 Protection of...: Connectors in gas/vapor service and light liquid service. (a) If an owner or operator elects to monitor... gas/vapor service and for connectors in light liquid service. The data for the two groups of...
Construction and Performance of a Superconducting Multipole Wiggler
NASA Astrophysics Data System (ADS)
Hwang, C. S.; Wang, B.; Chen, J. Y.; Chang, C. H.; Chen, H. H.; Fan, T. C.; Lin, F. Y.; Huang, M. H.; Chang, C. C.; Hsu, S. N.; Hsiung, G. Y.; Hsu, K. T.; Chen, J.; Chien, Y. C.; Chen, J. R.; Chen, C. T.
2004-05-01
A 3.2 Tesla superconducting multipole wiggler was designed and fabricated as an X-ray source. The magnet assembly, which consists of 32 pairs of racetrack NbTi superconducting coils with a periodic length of 60 mm, provides 28 effective poles. A 1.4056 m long elliptical cold-bore stainless steel beam duct with taper flanges and a wall thickness of 1 mm, was developed and constructed to fit the ultra-high vacuum condition for electron beam. The magnetic field strength was measured in liquid helium using a cryogenic Hall probe, revealing a field behavior very close to behavior consistent with the designed values. A Hall generator and the stretch wire methods are used to determine the transfer function of the peak field, the first and second integrated field distributions, and the good field region of the magnet. The quench protection of the magnet, the control algorithm for automatic filling of liquid helium, and the boil off rate of liquid helium and liquid nitrogen will also be discussed.
Fabrications of insulator-protected nanometer-sized electrode gaps
NASA Astrophysics Data System (ADS)
Arima, Akihide; Tsutsui, Makusu; Morikawa, Takanori; Yokota, Kazumichi; Taniguchi, Masateru
2014-03-01
We developed SiO2-coated mechanically controllable break junctions for accurate tunneling current measurements in an ionic solution. By breaking the junction, we created dielectric-protected Au nanoprobes with nanometer separation. We demonstrated that the insulator protection was capable to suppress the ionic contribution to the charge transport through the electrode gap, thereby enabled reliable characterizations of liquid-mediated exponential decay of the tunneling conductance in an electrolyte solution. From this, we found distinct roles of charge points such as molecular dipoles and ion species on the tunneling decay constant, which was attributed to local structures of molecules and ions in the confined space between the sensing electrodes. The device described here would provide improved biomolecular sensing capability of tunneling current sensors.
50 CFR 253.23 - Default and liquidation.
Code of Federal Regulations, 2013 CFR
2013-10-01
... limited to, where appropriate, retaking or arrest of collateral, foreclosure, restructuring, debarment, referral for debt collection, or liquidation as it deems best able to protect the U.S. Government's...
50 CFR 253.23 - Default and liquidation.
Code of Federal Regulations, 2014 CFR
2014-10-01
... limited to, where appropriate, retaking or arrest of collateral, foreclosure, restructuring, debarment, referral for debt collection, or liquidation as it deems best able to protect the U.S. Government's...
50 CFR 253.23 - Default and liquidation.
Code of Federal Regulations, 2012 CFR
2012-10-01
... limited to, where appropriate, retaking or arrest of collateral, foreclosure, restructuring, debarment, referral for debt collection, or liquidation as it deems best able to protect the U.S. Government's...
50 CFR 253.23 - Default and liquidation.
Code of Federal Regulations, 2011 CFR
2011-10-01
... limited to, where appropriate, retaking or arrest of collateral, foreclosure, restructuring, debarment, referral for debt collection, or liquidation as it deems best able to protect the U.S. Government's...
Dorandeu, F; Taysse, L; Boudry, I; Foquin, A; Hérodin, F; Mathieu, J; Daulon, S; Cruz, C; Lallement, G
2011-06-01
Exposure to lethal chemical warfare agents (CWAs) is no longer only a military issue due to the terrorist threat. Among the CWAs of concern are the organophosphorus nerve agent O-ethyl-S-(2[di-isopropylamino]ethyl)methyl-phosphonothioate (VX) and the vesicant sulfur mustard (SM). Although efficient means of decontamination are available, most of them lose their efficacy when decontamination is delayed after exposure of the bare skin. Alternatively, CWA skin penetration can be prevented by topical skin protectants. Active research in skin protection and decontamination is thus paramount. In vivo screening of decontaminants or skin protectants is usually time consuming and may be expensive depending on the animal species used. We were thus looking for a suitable, scientifically sound and cost-effective model, which is easy to handle. The euthymic hairless mouse Crl: SKH-1 (hr/hr) BR is widely used in some skin studies and has previously been described to be suitable for some experiments involving SM or SM analogs. To evaluate the response of this species, we studied the consequences of exposing male anaesthetized SKH-1 mice to either liquid VX or to SM, the latter being used in liquid form or as saturated vapours. Long-term effects of SM burn were also evaluated. The model was then used in the companion paper (Taysse et al.(1)).
40 CFR 1066.970 - Refueling test for liquid fuels.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 33 2014-07-01 2014-07-01 false Refueling test for liquid fuels. 1066... POLLUTION CONTROLS VEHICLE-TESTING PROCEDURES Evaporative Emission Test Procedures Evaporative and Refueling Emission Test Procedures for Motor Vehicles § 1066.970 Refueling test for liquid fuels. Except as described...
Zhang, Tao; Ding, Yuanyuan; An, Hongli; Feng, Liuxin; Wang, Sicen
2015-07-14
Tyrosine 367 Cysteine-fibroblast growth factor receptor 4 cell membrane chromatography combined with high-performance liquid chromatography and mass spectrometry was developed. Tyrosine 367 Cysteine-HEK293 cells were used as cell membrane stationary phase. Specificity and reproducibility of the cell membrane chromatography was evaluated using 1-tert-butyl-3-{2-[4-(diethylamino)butylamino]-6-(3,5-dimethoxyphenyl)pyrido[2,3-d]pyrimidin-7-yl}urea, Nimodipine and dexamethasone acetate. Then, anti-tumor components acting on Tyrosine 367 Cysteine-fibroblast growth factor receptor 4 were screened and identified from extracts of Ligusticum wallichii. Components from the extract were retained on the cell membrane chromatographic column. The retained fraction was directly eluted into high-performance liquid chromatography with mass spectrometry system for separation and identification. Finally, Levistolide A was identified as an active component from Ligusticum wallichii extracts. The 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl-tetrazolium bromide-formazan colorimetric assay revealed that Levistolide A inhibits proliferation of overexpressing the mutated receptor cells with dose-dependent manner. Phosphorylation of fibroblast growth factor receptor 4 was also decrease under Levistolide A treatment. Flex dock simulation verified that Levistolide A could bind with the tyrosine kinase domain of fibroblast growth factor receptor 4. Therefore, Levistolide A screened by the cell membrane chromatography combined with high-performance liquid chromatography and mass spectrometry can arrest cell growth. In conclusion, the two-dimensional high-performance liquid chromatography method can screen and identify potential anti-tumor ingredients which specifically act on the tyrosine kinase domain of the mutated fibroblast growth factor receptor 4. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Surface Tension Confines Cryogenic Liquid
NASA Technical Reports Server (NTRS)
Castles, Stephen H.; Schein, Michael E.
1989-01-01
New type of Dewar provides passive, constant-temperature cryogenic cooling for scientific instruments under normal-to low-gravity conditions. Known as Surface-Tension-Contained Liquid Cryogen Cooler (STCLCC), keeps liquid cryogen in known location inside the Dewar by trapping liquid inside spongelike material. Unique sponge material fills most of volume of inner tank. Sponge is all-silica, open-cell material similar to that used for Space Shuttle thermal-protection tiles.
Code of Federal Regulations, 2011 CFR
2011-07-01
... wastewater streams and liquid streams in open systems within an MCPU? 63.2485 Section 63.2485 Protection of... Compliance Requirements § 63.2485 What requirements must I meet for wastewater streams and liquid streams in... to your wastewater streams and liquid streams in open systems within an MCPU, except as specified in...
40 CFR 761.320 - Applicability.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 32 2012-07-01 2012-07-01 false Applicability. 761.320 Section 761.320 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES CONTROL ACT...-Implementing Alternative Extraction and Chemical Analysis Procedures for Non-liquid PCB Remediation Waste...
40 CFR 761.320 - Applicability.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 31 2014-07-01 2014-07-01 false Applicability. 761.320 Section 761.320 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES CONTROL ACT...-Implementing Alternative Extraction and Chemical Analysis Procedures for Non-liquid PCB Remediation Waste...
40 CFR 761.320 - Applicability.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 32 2013-07-01 2013-07-01 false Applicability. 761.320 Section 761.320 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES CONTROL ACT...-Implementing Alternative Extraction and Chemical Analysis Procedures for Non-liquid PCB Remediation Waste...
40 CFR 761.320 - Applicability.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 31 2011-07-01 2011-07-01 false Applicability. 761.320 Section 761.320 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES CONTROL ACT...-Implementing Alternative Extraction and Chemical Analysis Procedures for Non-liquid PCB Remediation Waste...
40 CFR 417.81 - Specialized definitions.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 30 2012-07-01 2012-07-01 false Specialized definitions. 417.81 Section 417.81 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS SOAP AND DETERGENT MANUFACTURING POINT SOURCE CATEGORY Manufacture of Liquid Soaps...
Electrocurtain coating process for coating solar mirrors
Kabagambe, Benjamin; Boyd, Donald W.; Buchanan, Michael J.; Kelly, Patrick; Kutilek, Luke A.; McCamy, James W.; McPheron, Douglas A.; Orosz, Gary R.; Limbacher, Raymond D.
2013-10-15
An electrically conductive protective coating or film is provided over the surface of a reflective coating of a solar mirror by flowing or directing a cation containing liquid and an anion containing liquid onto the conductive surface. The cation and the anion containing liquids are spaced from, and preferably out of contact with one another on the surface of the reflective coating as an electric current is moved through the anion containing liquid, the conductive surface between the liquids and the cation containing liquid to coat the conductive surface with the electrically conductive coating.
46 CFR 154.519 - Piping relief valves.
Code of Federal Regulations, 2014 CFR
2014-10-01
... Process Piping Systems § 154.519 Piping relief valves. (a) The liquid relief valve that protects the cargo piping system from liquid pressure exceeding the design pressure must discharge into: (1) A cargo tank; or (2) A cargo vent mast if that vent mast has a means for the detection and removal of the liquid...
46 CFR 154.519 - Piping relief valves.
Code of Federal Regulations, 2012 CFR
2012-10-01
... Process Piping Systems § 154.519 Piping relief valves. (a) The liquid relief valve that protects the cargo piping system from liquid pressure exceeding the design pressure must discharge into: (1) A cargo tank; or (2) A cargo vent mast if that vent mast has a means for the detection and removal of the liquid...
46 CFR 154.519 - Piping relief valves.
Code of Federal Regulations, 2013 CFR
2013-10-01
... Process Piping Systems § 154.519 Piping relief valves. (a) The liquid relief valve that protects the cargo piping system from liquid pressure exceeding the design pressure must discharge into: (1) A cargo tank; or (2) A cargo vent mast if that vent mast has a means for the detection and removal of the liquid...
46 CFR 154.519 - Piping relief valves.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Process Piping Systems § 154.519 Piping relief valves. (a) The liquid relief valve that protects the cargo piping system from liquid pressure exceeding the design pressure must discharge into: (1) A cargo tank; or (2) A cargo vent mast if that vent mast has a means for the detection and removal of the liquid...
49 CFR 176.315 - Fire protection requirements.
Code of Federal Regulations, 2011 CFR
2011-10-01
... combustible liquid being transported on board a vessel in a portable tank, rail tank car, or a motor vehicle... (flammable) and combustible liquids stowage areas must be fitted with an approved combination solid stream...
49 CFR 176.315 - Fire protection requirements.
Code of Federal Regulations, 2012 CFR
2012-10-01
... combustible liquid being transported on board a vessel in a portable tank, rail tank car, or a motor vehicle... (flammable) and combustible liquids stowage areas must be fitted with an approved combination solid stream...
49 CFR 176.315 - Fire protection requirements.
Code of Federal Regulations, 2013 CFR
2013-10-01
... combustible liquid being transported on board a vessel in a portable tank, rail tank car, or a motor vehicle... (flammable) and combustible liquids stowage areas must be fitted with an approved combination solid stream...
49 CFR 176.315 - Fire protection requirements.
Code of Federal Regulations, 2010 CFR
2010-10-01
... combustible liquid being transported on board a vessel in a portable tank, rail tank car, or a motor vehicle... (flammable) and combustible liquids stowage areas must be fitted with an approved combination solid stream...
Energy-loss return gate via liquid dielectric polarization.
Kim, Taehun; Yong, Hyungseok; Kim, Banseok; Kim, Dongseob; Choi, Dukhyun; Park, Yong Tae; Lee, Sangmin
2018-04-12
There has been much research on renewable energy-harvesting techniques. However, owing to increasing energy demands, significant energy-related issues remain to be solved. Efforts aimed at reducing the amount of energy loss in electric/electronic systems are essential for reducing energy consumption and protecting the environment. Here, we design an energy-loss return gate system that reduces energy loss from electric/electronic systems by utilizing the polarization of liquid dielectrics. The use of a liquid dielectric material in the energy-loss return gate generates electrostatic potential energy while reducing the dielectric loss of the electric/electronic system. Hence, an energy-loss return gate can make breakthrough impacts possible by amplifying energy-harvesting efficiency, lowering the power consumption of electronics, and storing the returned energy. Our study indicates the potential for enhancing energy-harvesting technologies for electric/electronics systems, while increasing the widespread development of these systems.
Shaw, Anugrah; Abbi, Ruchika
2004-01-01
Penetration of liquid pesticides through textile materials is a criterion for determining the performance of protective clothing used by pesticide handlers. The pipette method is frequently used to apply liquid pesticides onto textile materials to measure penetration. Typically, analytical techniques such as Gas Chromatography (GC) are used to measure percentage penetration. These techniques are labor intensive and costly. A simpler gravimetric method was developed, and tests were conducted to compare the gravimetric and GC methods of analysis. Three types of pesticide formulations and 4 fabrics were used for the study. Diluted pesticide formulations were pipetted onto the test specimens and percentage penetration was measured using the 2 methods. For homogeneous formulation, the results of the two methods were fairly comparable. However, due to the filtering action of the textile materials, there were differences in the percentage penetration between the 2 methods for formulations that were not homogeneous.
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1996-12-31
The project involves the construction of an 80,000 gallon per day (260 tons per day (TPD)) methanol unit utilizing coal-derived synthesis gas from Eastman`s integrated coal gasification facility. The new equipment consists of synthesis gas feed preparation and compression facilities, the liquid phase reactor and auxiliaries, product distillation facilities, and utilities. The technology to be demonstrated is the product of a cooperative development effort by Air Products and DOE in a program that started in 1981. Developed to enhance electric power generation using integrated gasification combined cycle (IGCC) technology, the LPMEOH{trademark} process is ideally suited for directly processing gases producedmore » by modern-day coal gasifiers. Originally tested at a small (10 TPD), DOE-owned experimental unit in LaPorte, Texas, the technology provides several improvements essential for the economic coproduction of methanol and electricity directly from gasified coal. This liquid phase process suspends fine catalyst particles in an inert liquid, forming a slurry. The slurry dissipates the heat of the chemical reaction away from the catalyst surface, protecting the catalyst and allowing the methanol synthesis reaction to proceed at higher rates. At the Eastman complex, the technology is being integrated with existing coal-gasifiers. A carefully developed test plan will allow operations at Eastman to simulate electricity demand load-following in coal-based IGCC facilities. The operations will also demonstrate the enhanced stability and heat dissipation of the conversion process, its reliable on/off operation, and its ability to produce methanol as a clean liquid fuel without additional upgrading.« less
Code of Federal Regulations, 2013 CFR
2013-07-01
... and Natural Gas Liquids 1 2 MM Table MM-1 to Subpart MM of Part 98 Protection of Environment... Factors for Petroleum Products and Natural Gas Liquids 1 2 Products Column A: density(metric tons/bbl... Natural Gas Liquids Aviation Gasoline 0.1120 85.00 0.3490 Special Naphthas 0.1222 84.76 0.3798 Lubricants...
Code of Federal Regulations, 2014 CFR
2014-07-01
... and Natural Gas Liquids 1 2 MM Table MM-1 to Subpart MM of Part 98 Protection of Environment... Factors for Petroleum Products and Natural Gas Liquids 1 2 Products Column A: density(metric tons/bbl... Natural Gas Liquids Aviation Gasoline 0.1120 85.00 0.3490 Special Naphthas 0.1222 84.76 0.3798 Lubricants...
Code of Federal Regulations, 2012 CFR
2012-07-01
... and Natural Gas Liquids 1 2 MM Table MM-1 to Subpart MM of Part 98 Protection of Environment... Factors for Petroleum Products and Natural Gas Liquids 1 2 Products Column A: density(metric tons/bbl... Natural Gas Liquids Aviation Gasoline 0.1120 85.00 0.3490 Special Naphthas 0.1222 84.76 0.3798 Lubricants...
Code of Federal Regulations, 2011 CFR
2011-07-01
... and Natural Gas Liquids 1 2 MM Table MM-1 to Subpart MM of Part 98 Protection of Environment... Factors for Petroleum Products and Natural Gas Liquids 1 2 Products Column A: density(metric tons/bbl... Natural Gas Liquids Aviation Gasoline 0.1120 85.00 0.3490 Special Naphthas 0.1222 84.76 0.3798 Lubricants...
Huang, Joanne; D'Souza, Ajit J.; Alarcon, Jason B.; Mikszta, John A.; Ford, Brandi M.; Ferriter, Matthew S.; Evans, Michelle; Stewart, Todd; Amemiya, Kei; Ulrich, Robert G.; Sullivan, Vincent J.
2009-01-01
The potential use of Yersinia pestis as a bioterror agent is a great concern. Development of a stable powder vaccine against Y. pestis and administration of the vaccine by minimally invasive methods could provide an alternative to the traditional liquid formulation and intramuscular injection. We evaluated a spray-freeze-dried powder vaccine containing a recombinant F1-V fusion protein of Y. pestis for vaccination against plaque in a mouse model. Mice were immunized with reconstituted spray-freeze-dried F1-V powder via intramuscular injection, microneedle-based intradermal delivery, or noninvasive intranasal administration. By intramuscular injection, the reconstituted powder induced serum antibody responses and provided protection against lethal subcutaneous challenge with 1,000 50% lethal doses of Y. pestis at levels equivalent to those elicited by unprocessed liquid formulations (70 to 90% protection). The feasibility of intradermal and intranasal delivery of reconstituted powder F1-V vaccine was also demonstrated. Overall, microneedle-based intradermal delivery was shown to be similar in efficacy to intramuscular injection, while intranasal administration required an extra dose of vaccine to achieve similar protection. In addition, the results suggest that seroconversion against F1 may be a better predictor of protection against Y. pestis challenge than seroconversion against either F1-V or V. In summary, we demonstrate the preclinical feasibility of using a reconstituted powder F1-V formulation and microneedle-based intradermal delivery to provide protective immunity against plague in a mouse model. Intranasal delivery, while feasible, was less effective than injection in this study. The potential use of these alternative delivery methods and a powder vaccine formulation may result in substantial health and economic benefits. PMID:19261773
Huang, Joanne; D'Souza, Ajit J; Alarcon, Jason B; Mikszta, John A; Ford, Brandi M; Ferriter, Matthew S; Evans, Michelle; Stewart, Todd; Amemiya, Kei; Ulrich, Robert G; Sullivan, Vincent J
2009-05-01
The potential use of Yersinia pestis as a bioterror agent is a great concern. Development of a stable powder vaccine against Y. pestis and administration of the vaccine by minimally invasive methods could provide an alternative to the traditional liquid formulation and intramuscular injection. We evaluated a spray-freeze-dried powder vaccine containing a recombinant F1-V fusion protein of Y. pestis for vaccination against plaque in a mouse model. Mice were immunized with reconstituted spray-freeze-dried F1-V powder via intramuscular injection, microneedle-based intradermal delivery, or noninvasive intranasal administration. By intramuscular injection, the reconstituted powder induced serum antibody responses and provided protection against lethal subcutaneous challenge with 1,000 50% lethal doses of Y. pestis at levels equivalent to those elicited by unprocessed liquid formulations (70 to 90% protection). The feasibility of intradermal and intranasal delivery of reconstituted powder F1-V vaccine was also demonstrated. Overall, microneedle-based intradermal delivery was shown to be similar in efficacy to intramuscular injection, while intranasal administration required an extra dose of vaccine to achieve similar protection. In addition, the results suggest that seroconversion against F1 may be a better predictor of protection against Y. pestis challenge than seroconversion against either F1-V or V. In summary, we demonstrate the preclinical feasibility of using a reconstituted powder F1-V formulation and microneedle-based intradermal delivery to provide protective immunity against plague in a mouse model. Intranasal delivery, while feasible, was less effective than injection in this study. The potential use of these alternative delivery methods and a powder vaccine formulation may result in substantial health and economic benefits.
Synthesis and in vitro characterization of entirely S-protected thiolated pectin for drug delivery.
Hintzen, Fabian; Hauptstein, Sabine; Perera, Glen; Bernkop-Schnürch, Andreas
2013-11-01
The study was aimed to synthesize a thiolated polymer (thiomer) that is resistant to oxidation in solutions above pH 5. In order to protect a pectin-cysteine conjugate against premature oxidation, the thiomer was S-protected by a disulfide connected leaving group. Therefore, 2-mercaptonicotinic acid was first coupled to L-cysteine by a disulfide exchange reaction and the purified product was subsequently attached to pectin by a carbodiimide mediated amid bond formation. The obtained fully S-protected thiolated pectin was in vitro characterized with respect to co- and mucoadhesive properties and stability toward oxidation. The results indicated a 1.8-fold and 2.3-fold enhanced disintegration time at pH 6.8 of the S-protected thiolated pectin (Pec-Cys-MNA) compared to thiolated pectin (Pec-Cys) and unmodified pectin (Pec). Moreover, rheological measurements of polymer/mucus mixtures showed a 1.6-fold (compared to Pec-Cys) and 6.7-fold (compared to Pec) increased dynamic viscosity of Pec-Cys-MNA. On the other hand, in the presence of a strong oxidizing agent such as H2O2 (0.3% v/v), no increase in viscosity of Pec-Cys-MNA could be observed. A 6-month experiment also demonstrated the long-term stability of a liquid formulation based on Pec-Cys-MNA. Further investigations proved that the first time all thiol groups on a thiolated polymer could be protected owing to the novel synthesis. Accordingly, these features may help to develop thiomer based liquid or gel formulations targeting mucosal surfaces such as nasal, ocular or vaginal drug delivery systems. Copyright © 2013 Elsevier B.V. All rights reserved.
Updated Liquid Secondary Waste Grout Formulation and Preliminary Waste Form Qualification
DOE Office of Scientific and Technical Information (OSTI.GOV)
Saslow, Sarah A.; Um, Wooyong; Russell, Renee L.
This report describes the results from liquid secondary waste grout (LSWG) formulation and cementitious waste form qualification tests performed by Pacific Northwest National Laboratory (PNNL) for Washington River Protection Solutions, LLC (WRPS). New formulations for preparing a cementitious waste form from a high-sulfate liquid secondary waste stream simulant, developed for Effluent Management Facility (EMF) process condensates merged with low activity waste (LAW) caustic scrubber, and the release of key constituents (e.g. 99Tc and 129I) from these monoliths were evaluated. This work supports a technology development program to address the technology needs for Hanford Site Effluent Treatment Facility (ETF) liquid secondarymore » waste (LSW) solidification and supports future Direct Feed Low-Activity Waste (DFLAW) operations. High-priority activities included simulant development, LSWG formulation, and waste form qualification. The work contained within this report relates to waste form development and testing and does not directly support the 2017 integrated disposal facility (IDF) performance assessment (PA). However, this work contains valuable information for use in PA maintenance past FY17, and for future waste form development efforts. The provided data should be used by (i) cementitious waste form scientists to further understanding of cementitious dissolution behavior, (ii) IDF PA modelers who use quantified constituent leachability, effective diffusivity, and partitioning coefficients to advance PA modeling efforts, and (iii) the U.S. Department of Energy (DOE) contractors and decision makers as they assess the IDF PA program. The results obtained help fill existing data gaps, support final selection of a LSWG waste form, and improve the technical defensibility of long-term waste form performance estimates.« less
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 29 2011-07-01 2009-07-01 true [Reserved] 409.33 Section 409.33 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS SUGAR PROCESSING POINT SOURCE CATEGORY Liquid Cane Sugar Refining Subcategory § 409.33 [Reserved] ...
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 28 2010-07-01 2010-07-01 true [Reserved] 409.33 Section 409.33 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS SUGAR PROCESSING POINT SOURCE CATEGORY Liquid Cane Sugar Refining Subcategory § 409.33 [Reserved] ...
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 28 2010-07-01 2010-07-01 true [Reserved] 417.164 Section 417.164 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS SOAP AND DETERGENT MANUFACTURING POINT SOURCE CATEGORY Manufacture of Liquid Detergents Subcategory § 417...
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 30 2012-07-01 2012-07-01 false [Reserved] 409.33 Section 409.33 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS SUGAR PROCESSING POINT SOURCE CATEGORY Liquid Cane Sugar Refining Subcategory § 409.33 [Reserved] ...
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 30 2013-07-01 2012-07-01 true [Reserved] 409.33 Section 409.33 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS SUGAR PROCESSING POINT SOURCE CATEGORY Liquid Cane Sugar Refining Subcategory § 409.33 [Reserved] ...
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 29 2014-07-01 2012-07-01 true [Reserved] 409.33 Section 409.33 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS SUGAR PROCESSING POINT SOURCE CATEGORY Liquid Cane Sugar Refining Subcategory § 409.33 [Reserved] ...
40 CFR 417.81 - Specialized definitions.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 29 2014-07-01 2012-07-01 true Specialized definitions. 417.81 Section 417.81 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS SOAP AND DETERGENT MANUFACTURING POINT SOURCE CATEGORY Manufacture of Liquid Soaps Subcategory...
40 CFR 417.81 - Specialized definitions.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 29 2011-07-01 2009-07-01 true Specialized definitions. 417.81 Section 417.81 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS SOAP AND DETERGENT MANUFACTURING POINT SOURCE CATEGORY Manufacture of Liquid Soaps Subcategory...
40 CFR 417.81 - Specialized definitions.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 30 2013-07-01 2012-07-01 true Specialized definitions. 417.81 Section 417.81 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS SOAP AND DETERGENT MANUFACTURING POINT SOURCE CATEGORY Manufacture of Liquid Soaps Subcategory...
40 CFR 417.81 - Specialized definitions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 28 2010-07-01 2010-07-01 true Specialized definitions. 417.81 Section 417.81 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS SOAP AND DETERGENT MANUFACTURING POINT SOURCE CATEGORY Manufacture of Liquid Soaps Subcategory...
Symmetry protected topological Luttinger liquids and the phase transition between them
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
2018-01-01
We show that a doped spin-1/2 ladder with antiferromagnetic intra-chain and ferromagnetic inter-chain coupling is a symmetry protected topologically non-trivial Luttinger liquid. Turning on a large easy-plane spin anisotropy drives the system to a topologically-trivial Luttinger liquid. Both phases have full spin gaps and exhibit power-law superconducting pair correlation. The Cooper pair symmetry is singletmore » $$d_{xy}$$ in the non-trivial phase and triplet $$S_z=0$$ in the trivial phase. The topologically non-trivial Luttinger liquid exhibits gapless spin excitations in the presence of a boundary, and it has no non-interacting or mean-field theory analog even when the fluctuating phase in the charge sector is pinned. As a function of the strength of spin anisotropy there is a topological phase transition upon which the spin gap closes. We speculate these Luttinger liquids are relevant to the superconductivity in metalized integer spin ladders or chains.« less
[Progress in the protective medicine against [correction of aganist] rocket propellents].
Hu, W X; Tan, C Y; Tan, S J; Jiang, J
1999-12-01
To review the progress in the major assignment, the organization and implementation of protection against liquid rocket propellent. The safety detection methods of the rocket [correction of rocked] propellent in the launching field were also discussed. Three steps of the sanitation and protection of the liquid propellent, the toxicity and the toxicology of hydrazine on central nervous system, blood circulatory system, assimilation system, respiratory system, immune system, liver, kidney, eye, skin and its hereditary toxicology were described. In addition, the clinical types of poisoning, the current principle and the common ways of the prevention and treatment of hydrazine and nitrogen oxides poisoning were summarized.
NiAl Coatings Investigated for Use in Reusable Launch Vehicles
NASA Technical Reports Server (NTRS)
Raj, Sai V.; Ghosn, Louis J.; Barrett, Charles A.
2003-01-01
As part of its major investment in the area of advanced space transportation, NASA is developing new technologies for use in the second- and third-generation designs of reusable launch vehicles. Among the prototype rocket engines being considered for these launch vehicles are those designed to use liquid hydrogen as the fuel and liquid oxygen as the oxidizer. Advanced copper alloys, such as copper-chromium-niobium (Cu-8(at.%)Cr- 4(at.%)Nb, also referred to as GRCop-84), which was invented at the NASA Glenn Research Center, are being considered for use as liner materials in the combustion chambers and nozzle ramps of these engines. However, previous experience has shown that, in rocket engines using liquid hydrogen and liquid oxygen, copper alloys are subject to a process called blanching, where the material undergoes environmental attack under the action of the combustion gases. In addition, the copper alloy liners undergo thermomechanical fatigue, which often results in an initially square cooling channel deforming into a dog-house shape. Clearly, there is an urgent need to develop new coatings to protect copper liners from environmental attack inside rocket chambers and to lower the temperature of the liners to reduce the probability of deformation and failure by thermomechanical fatigue.
Kamilari, Eleni; Farsalinos, Konstantinos; Poulas, Konstantinos; Kontoyannis, Christos G; Orkoula, Malvina G
2018-06-01
Electronic cigarettes are considered healthier alternatives to conventional cigarettes containing tobacco. They produce vapor through heating of the refill liquids (e-liquids) which consist of propylene glycol, vegetable glycerin, nicotine (in various concentrations), water and flavoring agents. Heavy metals may enter the refill liquid during the production, posing a risk for consumer's health due to their toxicity. The objective of the present study was the development of a methodology for the detection and quantitative analysis of cadmium (Cd), lead (Pb), nickel (Ni), copper (Cu), arsenic (As) and chromium (Cr), employing Total Reflection X-Ray Fluorescence Spectroscopy (TXRF) as an alternative technique to ICP-MS or ICP-OES commonly used for this type of analysis. TXRF was chosen due to its advantages, which include short analysis time, promptness, simultaneous multi-element analysis capability and minimum sample preparation, low purchase and operational cost. The proposed methodology was applied to a large number of electronic cigarette liquids commercially available, as well as their constituents, in order to evaluate their safety. TXRF may be a valuable tool for probing heavy metals in electronic cigarette refill liquids to serve for the protection of human health. Copyright © 2018 Elsevier Ltd. All rights reserved.
Vinci, Giuliana; Antonelli, Marta L; Preti, Raffaella
2013-02-01
Liquid-liquid microextraction coupled to LC with fluorescence detection for the determination of Environmental Protection Agency's 16 priority pollutant polycyclic aromatic hydrocarbons in rainwater has been developed. The optimization of the extraction method has involved several parameters, including the comparison between an ultrasonic bath and a magnetic stirrer as extractant apparatus, the choice of the extractant solvent, and the optimization of the extraction time. Liquid-liquid microextraction gave good results in terms of recoveries (from 73.6 to 102.8% in rainwater) and repeatability, with a very simple procedure and low solvent consumption. The reported chromatographic method uses a Core-Shell technology column, with particle size <3 μm instead of classical 5-μm particles column. The resulting backpressure was below 300 bar, allowing the use of a conventional HPLC system rather than the more expensive ultrahigh performance LC (UHPLC). An average decrease of 59% in run time and 75% in eluent consumption has been obtained, compared to classical HPLC methods, keeping good separation, sensitivity, and repeatability. The proposed conditions were successfully applied to the determinations of polycyclic aromatic hydrocarbons in genuine rainwater samples. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
49 CFR 195.571 - What criteria must I use to determine the adequacy of cathodic protection?
Code of Federal Regulations, 2011 CFR
2011-10-01
... of cathodic protection? 195.571 Section 195.571 Transportation Other Regulations Relating to... (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF HAZARDOUS LIQUIDS BY PIPELINE Corrosion Control § 195.571 What criteria must I use to determine the adequacy of cathodic protection? Cathodic protection required by this...
49 CFR 195.571 - What criteria must I use to determine the adequacy of cathodic protection?
Code of Federal Regulations, 2010 CFR
2010-10-01
... of cathodic protection? 195.571 Section 195.571 Transportation Other Regulations Relating to... (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF HAZARDOUS LIQUIDS BY PIPELINE Corrosion Control § 195.571 What criteria must I use to determine the adequacy of cathodic protection? Cathodic protection required by this...
Shimasaki, Noriko; Shinohara, Katsuaki; Morikawa, Hideki
2017-12-07
For occupational safety, healthcare workers must select and wear appropriate personal protective equipment (PPE), protective clothing, and masks as countermeasures against exposure to infectious body fluids and blood splash. It is important for healthcare workers to ensure the protective performance of each PPE against penetration of pathogens. The International Standards Organization (ISO) 22609 test evaluates the effectiveness of medical facemasks to protect against penetration of splashed synthetic blood. However, in this method, the protective performance is determined only visually, without quantification of leaked liquid volume. Therefore, in this study, we modified the ISO 22609 test method to quantify the volume of leaked liquid and obtain a more accurate assessment of the protection performance. We tested non-woven and woven materials used for masks or protective clothing, and the performance of each material was classified using this new method. We found that the quantity of leaked synthetic blood was dependent on the structural characteristics of each material. These findings will allow healthcare workers to select the most appropriate PPE for a given situation or task.
SHIMASAKI, Noriko; SHINOHARA, Katsuaki; MORIKAWA, Hideki
2017-01-01
For occupational safety, healthcare workers must select and wear appropriate personal protective equipment (PPE), protective clothing, and masks as countermeasures against exposure to infectious body fluids and blood splash. It is important for healthcare workers to ensure the protective performance of each PPE against penetration of pathogens. The International Standards Organization (ISO) 22609 test evaluates the effectiveness of medical facemasks to protect against penetration of splashed synthetic blood. However, in this method, the protective performance is determined only visually, without quantification of leaked liquid volume. Therefore, in this study, we modified the ISO 22609 test method to quantify the volume of leaked liquid and obtain a more accurate assessment of the protection performance. We tested non-woven and woven materials used for masks or protective clothing, and the performance of each material was classified using this new method. We found that the quantity of leaked synthetic blood was dependent on the structural characteristics of each material. These findings will allow healthcare workers to select the most appropriate PPE for a given situation or task. PMID:28978815
Treatment of Bottled Liquid Waste During Remediation of the Hanford 618-10 Burial Ground - 13001
DOE Office of Scientific and Technical Information (OSTI.GOV)
Faulk, Darrin E.; Pearson, Chris M.; Vedder, Barry L.
2013-07-01
A problematic waste form encountered during remediation of the Hanford Site 618-10 burial ground consists of bottled aqueous waste potentially contaminated with regulated metals. The liquid waste requires stabilization prior to landfill disposal. Prior remediation activities at other Hanford burial grounds resulted in a standard process for sampling and analyzing liquid waste using manual methods. Due to the highly dispersible characteristics of alpha contamination, and the potential for shock sensitive chemicals, a different method for bottle processing was needed for the 618-10 burial ground. Discussions with the United States Department of Energy (DOE) and United States Environmental Protection Agency (EPA)more » led to development of a modified approach. The modified approach involves treatment of liquid waste in bottles, up to one gallon per bottle, in a tray or box within the excavation of the remediation site. Bottles are placed in the box, covered with soil and fixative, crushed, and mixed with a Portland cement grout. The potential hazards of the liquid waste preclude sampling prior to treatment. Post treatment verification sampling is performed to demonstrate compliance with land disposal restrictions and disposal facility acceptance criteria. (authors)« less
40 CFR 409.34 - Pretreatment standards for existing sources.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 29 2011-07-01 2009-07-01 true Pretreatment standards for existing sources. 409.34 Section 409.34 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS SUGAR PROCESSING POINT SOURCE CATEGORY Liquid Cane Sugar Refining...
40 CFR 409.34 - Pretreatment standards for existing sources.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 28 2010-07-01 2010-07-01 true Pretreatment standards for existing sources. 409.34 Section 409.34 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS SUGAR PROCESSING POINT SOURCE CATEGORY Liquid Cane Sugar Refining...
40 CFR 409.34 - Pretreatment standards for existing sources.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 29 2014-07-01 2012-07-01 true Pretreatment standards for existing sources. 409.34 Section 409.34 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS SUGAR PROCESSING POINT SOURCE CATEGORY Liquid Cane Sugar Refining...
40 CFR 409.34 - Pretreatment standards for existing sources.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 30 2013-07-01 2012-07-01 true Pretreatment standards for existing sources. 409.34 Section 409.34 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS SUGAR PROCESSING POINT SOURCE CATEGORY Liquid Cane Sugar Refining...
40 CFR 409.34 - Pretreatment standards for existing sources.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 30 2012-07-01 2012-07-01 false Pretreatment standards for existing sources. 409.34 Section 409.34 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS SUGAR PROCESSING POINT SOURCE CATEGORY Liquid Cane Sugar Refining...
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 22 2012-07-01 2012-07-01 false Definitions. 98.408 Section 98.408 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) MANDATORY GREENHOUSE GAS REPORTING Suppliers of Natural Gas and Natural Gas Liquids § 98.408 Definitions. All terms...
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 22 2013-07-01 2013-07-01 false Definitions. 98.408 Section 98.408 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) MANDATORY GREENHOUSE GAS REPORTING Suppliers of Natural Gas and Natural Gas Liquids § 98.408 Definitions. All terms...
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 21 2014-07-01 2014-07-01 false Definitions. 98.408 Section 98.408 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) MANDATORY GREENHOUSE GAS REPORTING Suppliers of Natural Gas and Natural Gas Liquids § 98.408 Definitions. All terms...
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 21 2011-07-01 2011-07-01 false Definitions. 98.408 Section 98.408 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) MANDATORY GREENHOUSE GAS REPORTING Suppliers of Natural Gas and Natural Gas Liquids § 98.408 Definitions. All terms...
40 CFR 98.381 - Reporting threshold.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 22 2012-07-01 2012-07-01 false Reporting threshold. 98.381 Section 98.381 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) MANDATORY GREENHOUSE GAS REPORTING Suppliers of Coal-based Liquid Fuels § 98.381 Reporting threshold. Any...
40 CFR 98.381 - Reporting threshold.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Reporting threshold. 98.381 Section 98.381 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) MANDATORY GREENHOUSE GAS REPORTING Suppliers of Coal-based Liquid Fuels § 98.381 Reporting threshold. Any...
Prado, A H; Borges, M C; Eloy, J O; Peccinini, R G; Chorilli, M
2017-10-01
Cutaneous penetration is a critical factor in the use of sunscreen, as the compounds should not reach systemic circulation in order to avoid the induction of toxicity. The evaluation of the skin penetration and permeation of the UVB filter octyl methoxycinnamate (OMC) is essential for the development of a successful sunscreen formulation. Liquid-crystalline systems are innovative and potential carriers of OMC, which possess several advantages, including controlled release and protection of the filter from degradation. In this study, a new and effective method was developed using ultra-high performance liquid chromatography (UPLC) with ultraviolet detection (UV) for the quantitative analysis of penetration of OMC-loaded liquid crystalline systems into the skin. The following parameters were assessed in the method: selectivity, linearity, precision, accuracy, robustness, limit of detection (LOD), and limit of quantification (LOQ). The analytical curve was linear in the range from 0.25 to 250 μg.m-1, precise, with a standard deviation of 0.05-1.24%, with an accuracy in the range from 96.72 to 105.52%, and robust, with adequate values for the LOD and LOQ of 0.1 and 0.25 μg.mL -1, respectively. The method was successfully used to determine the in vitro skin permeation of OMC-loaded liquid crystalline systems. The results of the in vitro tests on Franz cells showed low cutaneous permeation and high retention of the OMC, particularly in the stratum corneum, owing to its high lipophilicity, which is desirable for a sunscreen formulation.
Code of Federal Regulations, 2014 CFR
2014-07-01
... for Mercury Liquid Collection 4 Table 4 to Subpart IIIII of Part 63 Protection of Environment... Pollutants: Mercury Emissions From Mercury Cell Chlor-Alkali Plants Pt. 63, Subpt. IIIII, Table 4 Table 4 to Subpart IIIII of Part 63—Work Practice Standards—Requirements for Mercury Liquid Collection As stated in...
Code of Federal Regulations, 2013 CFR
2013-07-01
... for Mercury Liquid Collection 4 Table 4 to Subpart IIIII of Part 63 Protection of Environment... Pollutants: Mercury Emissions From Mercury Cell Chlor-Alkali Plants Pt. 63, Subpt. IIIII, Table 4 Table 4 to Subpart IIIII of Part 63—Work Practice Standards—Requirements for Mercury Liquid Collection As stated in...
Code of Federal Regulations, 2012 CFR
2012-07-01
... for Mercury Liquid Collection 4 Table 4 to Subpart IIIII of Part 63 Protection of Environment... Pollutants: Mercury Emissions From Mercury Cell Chlor-Alkali Plants Pt. 63, Subpt. IIIII, Table 4 Table 4 to Subpart IIIII of Part 63—Work Practice Standards—Requirements for Mercury Liquid Collection As stated in...
Dissolution of NTO, DNAN, and Insensitive Munitions Formulations and Their Fates in Soils
2014-09-01
3 2 Mass loss measured by high precision liquid chromatography (HPLC) versus measured mass loss by... Liquid Chromatography IM Insensitive Munitions IMX Insensitive Munitions eXplosive k First-Order Transformation Rate Constant kphoto First...Performance Liquid Chromatography U.S. EPA United States Environmental Protection Agency WMRD Weapons and Materials Research Directorate ERDC/CRREL
40 CFR 61.242-8 - Standards: Pressure relief services in liquid service and connectors.
Code of Federal Regulations, 2012 CFR
2012-07-01
...: Pressure relief services in liquid service and connectors. (a) If evidence of a potential leak is found by visual, audible, olfactory, or any other detection method at pressure relief devices in liquid service... 40 Protection of Environment 9 2012-07-01 2012-07-01 false Standards: Pressure relief services in...
40 CFR 61.242-8 - Standards: Pressure relief services in liquid service and connectors.
Code of Federal Regulations, 2014 CFR
2014-07-01
...: Pressure relief services in liquid service and connectors. (a) If evidence of a potential leak is found by visual, audible, olfactory, or any other detection method at pressure relief devices in liquid service... 40 Protection of Environment 9 2014-07-01 2014-07-01 false Standards: Pressure relief services in...
40 CFR 61.242-8 - Standards: Pressure relief services in liquid service and connectors.
Code of Federal Regulations, 2010 CFR
2010-07-01
...: Pressure relief services in liquid service and connectors. (a) If evidence of a potential leak is found by visual, audible, olfactory, or any other detection method at pressure relief devices in liquid service... 40 Protection of Environment 8 2010-07-01 2010-07-01 false Standards: Pressure relief services in...
40 CFR 61.242-8 - Standards: Pressure relief services in liquid service and connectors.
Code of Federal Regulations, 2011 CFR
2011-07-01
...: Pressure relief services in liquid service and connectors. (a) If evidence of a potential leak is found by visual, audible, olfactory, or any other detection method at pressure relief devices in liquid service... 40 Protection of Environment 8 2011-07-01 2011-07-01 false Standards: Pressure relief services in...
40 CFR 61.242-8 - Standards: Pressure relief services in liquid service and connectors.
Code of Federal Regulations, 2013 CFR
2013-07-01
...: Pressure relief services in liquid service and connectors. (a) If evidence of a potential leak is found by visual, audible, olfactory, or any other detection method at pressure relief devices in liquid service... 40 Protection of Environment 9 2013-07-01 2013-07-01 false Standards: Pressure relief services in...
Litvinov, Julia; Wang, Yi-Ju; George, Jinnie; Chinwangso, Pawilai; Brankovic, Stanko; Willson, Richard C.; Litvinov, Dmitri
2013-01-01
This paper describes synthesis of ultrathin pinhole-free insulating aluminum oxide layers for electronic device protection in corrosive liquid environments, such as phosphate buffered saline (PBS) or clinical fluids, to enable emerging biomedical applications such as biomolecular sensors. A pinhole-free 25-nm thick amorphous aluminum oxide layer has been achieved using ultra-high vacuum DC magnetron reactive sputtering of aluminum in oxygen/argon plasma followed by oxygen plasma post-processing. Deposition parameters were optimized to achieve the best corrosion protection of lithographically defined device structures. Electrochemical deposition of copper through the aluminum oxide layers was used to detect the presence (or absence) of pinholes. FTIR, XPS, and spectroscopic ellipsometry were used to characterize the material properties of the protective layers. Electrical resistance of the copper device structures protected by the aluminum oxide layers and exposed to a PBS solution was used as a metric to evaluate the long-term stability of these device structures. PMID:23682201
Farajzadeh, Mir Ali; Aghdam, Mehri Bakhshizadeh; Mogaddam, Mohammad Reza Afshar; Nabil, Ali Akbar Alizadeh
2018-06-06
Simultaneous derivatization and air-assisted liquid-liquid microextraction using an organic solvent lighter than water has been developed for the extraction of some parabens in different samples with the aid of a newly designed device for collecting the extractant. For this purpose, the sample solution is transferred into a glass test tube and a few microliters of acetic anhydride (as a derivatization agent) and p-xylene (as an extraction solvent) are added to the solution. After performing the procedure, the homemade device consists of an inverse funnel with a capillary tube placed into the tube. In this step, the collected extraction solvent and a part of the aqueous solution are transferred into the device and the organic phase indwells in the capillary tube of the device. Under the optimal conditions, limits of detection and quantification for the analytes were obtained in the ranges of 0.90-2.7 and 3.0-6.1 ng mL -1 , respectively. The enrichment and enhancement factors were in the ranges of 370-430 and 489-660, respectively. The method precision, expressed as the relative standard deviation, was within the ranges of 4-6% (n = 6) and 4-9% (n = 4) for intra- and inter-day precisions, respectively. The proposed method was successfully used for the determination of methyl-, ethyl-, and propyl parabens in cosmetic, hygiene, and food samples, and personal care products. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Creation of Woven Structures Impacting Self-cleaning Superoleophobicity
NASA Astrophysics Data System (ADS)
Lim, Jihye
For protection of human life from harmful or toxic liquids in working areas, solid surface resistance to liquid with low surface tension (e.g. oil) should be achieved in the outermost layer of protective clothing. Based on the literature review, multiscale structures were emphasized because they can increase roughness on a solid surface and create more void spaces of different sizes. The roughness and void spaces contribute to creating a liquid-vapor interface and reducing the liquid contact area to the solid surface. Woven fabric inherently consists of multiscale structures by its construction: microscale in a yarn structure and macroscale in a fabric structure. When the solid surface tension is low relative to oil, creating an appropriate structural geometry will become a critical way to obtain a superoleophobic surface for oil-resistance. Theoretical modeling and experiments with actual fabric samples were utilized to predict and prove the highest performing structural geometry in woven fabric, respectively. The theoretical geometric modeling accounted for the different weave structures, the yarn compression by the yarn flattening factor, e, and the void space by the void space ratio to the fiber or yarn diameter, T, impacting the liquid apparent contact angle on a fabric surface. The Cassie-Baxter equations were developed using Young's contact angle, thetae, thetae and e, or thetae, e, and T, to predict the liquid apparent contact angle for different geometries. In addition, to prevent a liquid's penetration into a solid structure, the ranges of the protuberance height (>> h2) and distance (< 4ℓ 2 cap) were predicted by the definition of the Laplace pressure, the capillary pressure, and the sagging phenomenon. Those predictions were in strong agreement with the results from the empirical experiment using the actual woven fabric samples. This study identified the impact of the geometries in yarn and woven fabric structures on the fabric resistance against oil through theoretical modeling and experiments. The results suggest particular weave structures, the range of the void space (or the protuberance distance) and the protuberance height in the yarn and fabric structures for the highest performing self-cleaning superoleophobic woven fabric surface.
Defence Reporter. Summer/Autumn 2011
2011-01-01
of protection afforded by this material was determined against a liquid challenge. R000259AA Cermet Materials for Armour Applications Dstl Porton...initial research, however areas of focus have been identified and a comprehensive plan of study has been developed. R000261FE Force Multipliers in... study was not intended to be a rigorous quantitative analysis of COIN. It has identified six factors that have had an overall positive effect upon the
40 CFR 409.35 - Standards of performance for new sources.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 29 2011-07-01 2009-07-01 true Standards of performance for new sources. 409.35 Section 409.35 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS SUGAR PROCESSING POINT SOURCE CATEGORY Liquid Cane Sugar Refining...
40 CFR 409.35 - Standards of performance for new sources.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 28 2010-07-01 2010-07-01 true Standards of performance for new sources. 409.35 Section 409.35 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS SUGAR PROCESSING POINT SOURCE CATEGORY Liquid Cane Sugar Refining...
40 CFR 761.326 - Conducting the comparison study.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 32 2013-07-01 2013-07-01 false Conducting the comparison study. 761.326 Section 761.326 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC...-liquid PCB Remediation Waste Samples § 761.326 Conducting the comparison study. Extract or analyze the...
40 CFR 761.326 - Conducting the comparison study.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 32 2012-07-01 2012-07-01 false Conducting the comparison study. 761.326 Section 761.326 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC...-liquid PCB Remediation Waste Samples § 761.326 Conducting the comparison study. Extract or analyze the...
40 CFR 761.326 - Conducting the comparison study.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 31 2014-07-01 2014-07-01 false Conducting the comparison study. 761.326 Section 761.326 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC...-liquid PCB Remediation Waste Samples § 761.326 Conducting the comparison study. Extract or analyze the...
40 CFR 409.35 - Standards of performance for new sources.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 30 2013-07-01 2012-07-01 true Standards of performance for new sources. 409.35 Section 409.35 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS SUGAR PROCESSING POINT SOURCE CATEGORY Liquid Cane Sugar Refining...
40 CFR 409.35 - Standards of performance for new sources.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 30 2012-07-01 2012-07-01 false Standards of performance for new sources. 409.35 Section 409.35 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS SUGAR PROCESSING POINT SOURCE CATEGORY Liquid Cane Sugar Refining...
40 CFR 409.35 - Standards of performance for new sources.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 29 2014-07-01 2012-07-01 true Standards of performance for new sources. 409.35 Section 409.35 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS SUGAR PROCESSING POINT SOURCE CATEGORY Liquid Cane Sugar Refining...
40 CFR 417.86 - Pretreatment standards for new sources.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 29 2014-07-01 2012-07-01 true Pretreatment standards for new sources. 417.86 Section 417.86 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS SOAP AND DETERGENT MANUFACTURING POINT SOURCE CATEGORY Manufacture of Liquid Soaps...
40 CFR 417.86 - Pretreatment standards for new sources.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 29 2011-07-01 2009-07-01 true Pretreatment standards for new sources. 417.86 Section 417.86 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS SOAP AND DETERGENT MANUFACTURING POINT SOURCE CATEGORY Manufacture of Liquid Soaps...
40 CFR 417.86 - Pretreatment standards for new sources.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 30 2012-07-01 2012-07-01 false Pretreatment standards for new sources. 417.86 Section 417.86 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS SOAP AND DETERGENT MANUFACTURING POINT SOURCE CATEGORY Manufacture of Liquid Soaps...
40 CFR 417.86 - Pretreatment standards for new sources.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 28 2010-07-01 2010-07-01 true Pretreatment standards for new sources. 417.86 Section 417.86 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS SOAP AND DETERGENT MANUFACTURING POINT SOURCE CATEGORY Manufacture of Liquid Soaps...
40 CFR 417.86 - Pretreatment standards for new sources.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 30 2013-07-01 2012-07-01 true Pretreatment standards for new sources. 417.86 Section 417.86 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS SOAP AND DETERGENT MANUFACTURING POINT SOURCE CATEGORY Manufacture of Liquid Soaps...
Study on micro-bend light transmission performance of novel liquid-core optical fiber
NASA Astrophysics Data System (ADS)
Ma, Junyan; Zhao, Zhimin; Wang, Kaisheng; Guo, Linfeng
2007-01-01
With the increasing development of material technology and electronic integration technology, optical fiber and its using in smart structure have become hot in the field of material research. And liquid-core optical fiber is a special kind of optical fiber, which is made using liquid material as core and polymer material as optical layer and protective covering, and it has the characteristics of large core diameter, high numerical aperture, large-scope and efficient spectrum transmission and long life for using. So the liquid-core optical fiber is very suitable for spectrum cure, ultraviolet solidification, fluorescence detection, criminal investigation and evidence obtainment, etc, and especially as light transfer element in some new structures for the measurement of some signals, such as concentration, voltage, temperature, light intensity and so on. In this paper, the novel liquid-core optical fiber is self-made, and then through the test of its light transmission performance in free state, the relation between axial micro-bend and light-intensity loss are presented. When the liquid-core optical fiber is micro-bent axially, along with the axial displacement's increase, output power of light is reducing increasingly, and approximately has linear relation to micro-displacement in a range. According to the results liquid-core fiber-optic micro-bend sensor can be designed to measure micro-displacement of the tested objects. Experimental data and analysis provide experimental basis for further application of liquid-core optical fiber.
Symmetry enriched U(1) quantum spin liquids
NASA Astrophysics Data System (ADS)
Zou, Liujun; Wang, Chong; Senthil, T.
2018-05-01
We classify and characterize three-dimensional U (1 ) quantum spin liquids [deconfined U (1 ) gauge theories] with global symmetries. These spin liquids have an emergent gapless photon and emergent electric/magnetic excitations (which we assume are gapped). We first discuss in great detail the case with time-reversal and SO(3 ) spin rotational symmetries. We find there are 15 distinct such quantum spin liquids based on the properties of bulk excitations. We show how to interpret them as gauged symmetry-protected topological states (SPTs). Some of these states possess fractional response to an external SO (3 ) gauge field, due to which we dub them "fractional topological paramagnets." We identify 11 other anomalous states that can be grouped into three anomaly classes. The classification is further refined by weakly coupling these quantum spin liquids to bosonic symmetry protected topological (SPT) phases with the same symmetry. This refinement does not modify the bulk excitation structure but modifies universal surface properties. Taking this refinement into account, we find there are 168 distinct such U (1 ) quantum spin liquids. After this warm-up, we provide a general framework to classify symmetry enriched U (1 ) quantum spin liquids for a large class of symmetries. As a more complex example, we discuss U (1 ) quantum spin liquids with time-reversal and Z2 symmetries in detail. Based on the properties of the bulk excitations, we find there are 38 distinct such spin liquids that are anomaly-free. There are also 37 anomalous U (1 ) quantum spin liquids with this symmetry. Finally, we briefly discuss the classification of U (1 ) quantum spin liquids enriched by some other symmetries.
System for removing liquid waste from a tank
Meneely, Timothy K.; Sherbine, Catherine A.
1994-01-01
A tank especially suited for nuclear applications is disclosed. The tank comprises a tank shell for protectively surrounding the liquid contained therein; an inlet positioned on the tank for passing a liquid into the tank; a sump positioned in an interior portion of the tank for forming a reservoir of the liquid; a sloped incline for resting the tank thereon and for creating a natural flow of the liquid toward the sump; a pump disposed adjacent the tank for pumping the liquid; and a pipe attached to the pump and extending into the sump for passing the liquid therethrough. The pump pumps the liquid in the sump through the pipe and into the pump for discharging the liquid out of the tank.
System for removing liquid waste from a tank
Meneely, T.K.; Sherbine, C.A.
1994-04-26
A tank especially suited for nuclear applications is disclosed. The tank comprises a tank shell for protectively surrounding the liquid contained therein; an inlet positioned on the tank for passing a liquid into the tank; a sump positioned in an interior portion of the tank for forming a reservoir of the liquid; a sloped incline for resting the tank thereon and for creating a natural flow of the liquid toward the sump; a pump disposed adjacent the tank for pumping the liquid; and a pipe attached to the pump and extending into the sump for passing the liquid there through. The pump pumps the liquid in the sump through the pipe and into the pump for discharging the liquid out of the tank. 2 figures.
Ultrasonic technique for monitoring of liquid density variations
NASA Astrophysics Data System (ADS)
Kazys, R.; Rekuviene, R.; Sliteris, R.; Mazeika, L.; Zukauskas, E.
2015-01-01
A novel ultrasonic measurement technique for density measurements of different liquids in extreme conditions has been developed. The proposed density measurement method is based on transformation of the acoustic impedance of the measured liquid. The higher accuracy of measurements is achieved by means of the λ/4 acoustic matching layer between the load and the ultrasonic waveguide transducer. Introduction of the matching layer enhances sensitivity of the measurement system. Sometimes, the density measurements must be performed in very complex conditions: high temperature (up to 200 °C), pressure (up to 10 MPa), and high chemical activity of the medium under measurement. In this case, the special geometry metal waveguides are proposed to use in order to protect the piezoelectric transducer surface from influence of a high temperature. The experimental set-up of technique was calibrated using the reference liquids with different densities: ethyl ether, ethyl alcohol, distilled water, and different concentration (20%, 40%, and 60%) sugar-water solutions. The uncertainty of measurements is less than 1%. The proposed measurement method was verified in real conditions by monitoring the density of a melted polypropylene during manufacturing process.
NASA Technical Reports Server (NTRS)
Waller, Jess M.; Williams, James H.; Fries, Joseph (Technical Monitor)
1999-01-01
The permeation resistance of chlorinated polyethylene (CPE) used in totally encapsulating chemical protective suits against the aerospace fuels hydrazine, monomethylhydrazine, and uns-dimethylhydrazine was determined by measuring the breakthrough time (BT) and time-averaged vapor transmission rate (VTR) using procedures consistent with ASTM F 739 and ASTM F 1383. Two exposure scenarios were simulated: a 2 hour (h) fuel vapor exposure, and a liquid fuel "splash" followed by a 2 h vapor exposure. To simulate internal suit pressure during operation, a positive differential pressure of 0.3 in. water (75 Pa) on the collection side of the permeation apparatus was used. Using the available data, a model was developed to estimate propellant concentrations inside an air-line fed, totally encapsulating chemical protective suit. Concentrations were calculated under simulated conditions of fixed vapor transmission rate, variable breathing air flow rate, and variable splash exposure area. Calculations showed that the maximum allowable permeation rates of hydrazine fuels through CPE were of the order of 0.05 to 0.08 ng/sq cm min for encapsulating suits with low breathing air flow rates (of the order of 5 scfm or 140 L min-1). Above these permeation rates, the 10 parts-per-billion (ppb) threshold limit value time-weighted average could be exceeded. To evaluate suit performance at 10 ppb threshold-limiting value/time-weighted average level concentrations, use of a sensitive analytical method such as cation exchange high performance liquid chromatography with amperometric detection was found to be essential. The analytical detection limit determines the lowest measurable VTR, which in turn governed the lowest per meant concentration that could be calculated inside the totally encapsulating chemical protective suit.
2000-04-14
Center Director Roy Bridges (left) dons protective apron, gloves and face shield before the "ribbon-breaking" to open the new Cryogenic Testbed Facility. Part of the normal ceremonial ribbon was replaced with plastic tubing and frozen in liquid nitrogen for the event. Bridges hit the tubing with a small hammer to break it. The Cryogenics Testbed was built to provide cryogenics engineering development and testing services to meet the needs of industry. It will also support commercial, government and academic customers for technology development initiatives on the field of cryogenics. The facility is jointly managed by NASA and Dynacs Engineering Co. , NASA/SC's Engineering Development contractor
2000-04-14
Center Director Roy Bridges (left), wearing protective apron, gloves and face shield, watches as liquid nitrogen is poured into a container to freeze the plastic tubing for a special "ribbon-breaking" to open the new Cryogenic Testbed Facility. Bridges hit the section of tubing with a small hammer to break it. The Cryogenics Testbed was built to provide cryogenics engineering development and testing services to meet the needs of industry. It will also support commercial, government and academic customers for technology development initiatives on the field of cryogenics. The facility is jointly managed by NASA and Dynacs Engineering Co. , NASA/SC's Engineering Development contractor
46 CFR 151.50-73 - Chemical protective clothing.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 5 2010-10-01 2010-10-01 false Chemical protective clothing. 151.50-73 Section 151.50... BARGES CARRYING BULK LIQUID HAZARDOUS MATERIAL CARGOES Special Requirements § 151.50-73 Chemical... of cargo handling operations shall ensure that the following chemical protective clothing constructed...
46 CFR 151.50-73 - Chemical protective clothing.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 5 2011-10-01 2011-10-01 false Chemical protective clothing. 151.50-73 Section 151.50... BARGES CARRYING BULK LIQUID HAZARDOUS MATERIAL CARGOES Special Requirements § 151.50-73 Chemical... of cargo handling operations shall ensure that the following chemical protective clothing constructed...
40 CFR 409.36 - Pretreatment standards for new sources.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 29 2011-07-01 2009-07-01 true Pretreatment standards for new sources. 409.36 Section 409.36 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS SUGAR PROCESSING POINT SOURCE CATEGORY Liquid Cane Sugar Refining Subcategory § 409...
40 CFR 409.36 - Pretreatment standards for new sources.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 28 2010-07-01 2010-07-01 true Pretreatment standards for new sources. 409.36 Section 409.36 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS SUGAR PROCESSING POINT SOURCE CATEGORY Liquid Cane Sugar Refining Subcategory § 409...
46 CFR 151.50-73 - Chemical protective clothing.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 5 2012-10-01 2012-10-01 false Chemical protective clothing. 151.50-73 Section 151.50... BARGES CARRYING BULK LIQUID HAZARDOUS MATERIAL CARGOES Special Requirements § 151.50-73 Chemical... of cargo handling operations shall ensure that the following chemical protective clothing constructed...
46 CFR 151.50-73 - Chemical protective clothing.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 5 2014-10-01 2014-10-01 false Chemical protective clothing. 151.50-73 Section 151.50... BARGES CARRYING BULK LIQUID HAZARDOUS MATERIAL CARGOES Special Requirements § 151.50-73 Chemical... of cargo handling operations shall ensure that the following chemical protective clothing constructed...
46 CFR 151.50-73 - Chemical protective clothing.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 5 2013-10-01 2013-10-01 false Chemical protective clothing. 151.50-73 Section 151.50... BARGES CARRYING BULK LIQUID HAZARDOUS MATERIAL CARGOES Special Requirements § 151.50-73 Chemical... of cargo handling operations shall ensure that the following chemical protective clothing constructed...
40 CFR 409.36 - Pretreatment standards for new sources.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 30 2013-07-01 2012-07-01 true Pretreatment standards for new sources. 409.36 Section 409.36 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS SUGAR PROCESSING POINT SOURCE CATEGORY Liquid Cane Sugar Refining Subcategory § 409...
40 CFR 409.36 - Pretreatment standards for new sources.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 30 2012-07-01 2012-07-01 false Pretreatment standards for new sources. 409.36 Section 409.36 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS SUGAR PROCESSING POINT SOURCE CATEGORY Liquid Cane Sugar Refining Subcategory § 409...
40 CFR 409.36 - Pretreatment standards for new sources.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 29 2014-07-01 2012-07-01 true Pretreatment standards for new sources. 409.36 Section 409.36 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS SUGAR PROCESSING POINT SOURCE CATEGORY Liquid Cane Sugar Refining Subcategory § 409...
A perfluorochemical loss/restoration (L/R) system for tidal liquid ventilation.
Libros, R; Philips, C M; Wolfson, M R; Shaffer, T H
2000-01-01
Tidal liquid ventilation is the transport of dissolved respiratory gases via volume exchange of perfluorochemical (PFC) liquid to and from the PFC-filled lung. All gas-liquid surface tension is eliminated, increasing compliance and providing lung protection due to lower inflation pressures. Tidal liquid ventilation is achieved by cycling fluid from a reservoir to and from the lung by a ventilator. Current approaches are microprocessor-based with feedback control. During inspiration, warmed oxygenated PFC liquid is pumped from a fluid reservoir/gas exchanger into the lung. PFC fluid is conserved by condensing (60-80% efficiency) vapor in the expired gas. A feedback-control system was developed to automatically replace PFC lost due to condenser inefficiency. This loss/restoration (L/R) system consists of a PFC-vapor thermal detector (+/- 2.5%), pneumatics, amplifiers, a gas flow detector (+/- 1%), a PFC pump (+/- 5%), and a controller. Gravimetric studies of perflubron loss from a flask due to evaporation were compared with experimental L/R results and found to be within +/- 1.4%. In addition, when L/R studies were conducted with a previously reported liquid ventilation system over a four-hour period, the L/R system maintained system perflubron volume to within +/- 1% of prime volume and 11.5% of replacement volume, and the difference between experimental PFC loss and that of the L/R system was 1.8 mL/hr. These studies suggest that the PFC L/R system may have significant economic (appropriate dosing for PFC loss) as well as physiologic (maintenance of PFC inventory in the lungs and liquid ventilator) impact on liquid ventilation procedures.
Carlotto, Juliane; da Silva, Luisa M; Dartora, Nessana; Maria-Ferreira, Daniele; Sabry, Diego de A; Filho, Arquimedes P S; de Paula Werner, Maria F; Sassaki, Guilherme L; Gorin, Philip A J; Iacomini, Marcello; Cipriani, Thales R; de Souza, Lauro M
2015-04-01
Leaves of Arctium lappa contain several mono- and dicaffeoylquinic acids, as evaluated by liquid chromatography-mass spectrometry. In order to investigate the protection on gastric mucosa against ulcers, rats were treated with fractions from leaf extract prior to ethanol-induced ulcers. The original fraction obtained as ethanol soluble fraction from hot aqueous extract was able to protect de gastric mucosa, and this effect was retained in the ethyl acetate fraction, obtained from liquid/liquid fractionation. The main compound in this fraction was isolated and chemically characterized by nuclear magnetic resonance and mass spectrometry, assisted by isopropylidene derivatization which gave rise a mass increment of 40 units. Therefore, the underivatized compound that had m/z 515.119 [M-H](-) was shifted to m/z 555.151, being confirmed as 1,3-O-dicaffeoylquinic acid, which presented an ED50 of 57 µg kg(-1) on gastric protection, lesser than the therapeutic concentration of omeprazole (40 mg kg(-1)). Copyright © 2014 Elsevier B.V. All rights reserved.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Liquid Streams in Open Systems Within an MCPU 7 Table 7 to Subpart FFFF of Part 63 Protection of... FOR HAZARDOUS AIR POLLUTANTS FOR SOURCE CATEGORIES National Emission Standards for Hazardous Air... of Part 63—Requirements for Wastewater Streams and Liquid Streams in Open Systems Within an MCPU As...
Code of Federal Regulations, 2012 CFR
2012-07-01
... wastewater streams and liquid streams in open systems within an MCPU? 63.2485 Section 63.2485 Protection of... Standards, and Compliance Requirements § 63.2485 What requirements must I meet for wastewater streams and... subpart that applies to your wastewater streams and liquid streams in open systems within an MCPU, except...
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 13 2012-07-01 2012-07-01 false Requirements for Wastewater Streams... to Subpart FFFF of Part 63—Requirements for Wastewater Streams and Liquid Streams in Open Systems... applies to your wastewater streams and liquid streams in open systems within an MCPU: For each . . . You...
Code of Federal Regulations, 2013 CFR
2013-07-01
... wastewater streams and liquid streams in open systems within an MCPU? 63.2485 Section 63.2485 Protection of... Standards, and Compliance Requirements § 63.2485 What requirements must I meet for wastewater streams and... subpart that applies to your wastewater streams and liquid streams in open systems within an MCPU, except...
Code of Federal Regulations, 2014 CFR
2014-07-01
... wastewater streams and liquid streams in open systems within an MCPU? 63.2485 Section 63.2485 Protection of... Standards, and Compliance Requirements § 63.2485 What requirements must I meet for wastewater streams and... subpart that applies to your wastewater streams and liquid streams in open systems within an MCPU, except...
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 13 2014-07-01 2014-07-01 false Requirements for Wastewater Streams... to Subpart FFFF of Part 63—Requirements for Wastewater Streams and Liquid Streams in Open Systems... applies to your wastewater streams and liquid streams in open systems within an MCPU: For each . . . You...
40 CFR 63.1027 - Connectors in gas and vapor service and in light liquid service standards.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Standards § 63.1027 Connectors in gas and vapor service and in light liquid service standards. (a..., the owner or operator shall monitor all connectors in gas and vapor and light liquid service as... 40 Protection of Environment 10 2011-07-01 2011-07-01 false Connectors in gas and vapor service...
40 CFR 63.1006 - Valves in gas and vapor service and in light liquid service standards.
Code of Federal Regulations, 2011 CFR
2011-07-01
... § 63.1006 Valves in gas and vapor service and in light liquid service standards. (a) Compliance... requested by the Administrator. For each such demonstration, all valves in gas and vapor and light liquid... 40 Protection of Environment 10 2011-07-01 2011-07-01 false Valves in gas and vapor service and in...
40 CFR 60.482-11a - Standards: Connectors in gas/vapor service and in light liquid service.
Code of Federal Regulations, 2010 CFR
2010-07-01
...-11a Standards: Connectors in gas/vapor service and in light liquid service. (a) The owner or operator... connectors in gas and vapor and light liquid service as specified in paragraphs (a) and (b)(3) of this... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Standards: Connectors in gas/vapor...
40 CFR 60.482-11a - Standards: Connectors in gas/vapor service and in light liquid service.
Code of Federal Regulations, 2013 CFR
2013-07-01
...-11a Standards: Connectors in gas/vapor service and in light liquid service. (a) The owner or operator... connectors in gas and vapor and light liquid service as specified in paragraphs (a) and (b)(3) of this... 40 Protection of Environment 7 2013-07-01 2013-07-01 false Standards: Connectors in gas/vapor...
40 CFR 60.482-11a - Standards: Connectors in gas/vapor service and in light liquid service.
Code of Federal Regulations, 2012 CFR
2012-07-01
...-11a Standards: Connectors in gas/vapor service and in light liquid service. (a) The owner or operator... connectors in gas and vapor and light liquid service as specified in paragraphs (a) and (b)(3) of this... 40 Protection of Environment 7 2012-07-01 2012-07-01 false Standards: Connectors in gas/vapor...
40 CFR 63.1006 - Valves in gas and vapor service and in light liquid service standards.
Code of Federal Regulations, 2014 CFR
2014-07-01
... § 63.1006 Valves in gas and vapor service and in light liquid service standards. (a) Compliance... requested by the Administrator. For each such demonstration, all valves in gas and vapor and light liquid... 40 Protection of Environment 11 2014-07-01 2014-07-01 false Valves in gas and vapor service and in...
40 CFR 63.1006 - Valves in gas and vapor service and in light liquid service standards.
Code of Federal Regulations, 2013 CFR
2013-07-01
... § 63.1006 Valves in gas and vapor service and in light liquid service standards. (a) Compliance... requested by the Administrator. For each such demonstration, all valves in gas and vapor and light liquid... 40 Protection of Environment 11 2013-07-01 2013-07-01 false Valves in gas and vapor service and in...
40 CFR 63.1027 - Connectors in gas and vapor service and in light liquid service standards.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Standards § 63.1027 Connectors in gas and vapor service and in light liquid service standards. (a..., the owner or operator shall monitor all connectors in gas and vapor and light liquid service as... 40 Protection of Environment 10 2010-07-01 2010-07-01 false Connectors in gas and vapor service...
40 CFR 63.1027 - Connectors in gas and vapor service and in light liquid service standards.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Standards § 63.1027 Connectors in gas and vapor service and in light liquid service standards. (a..., the owner or operator shall monitor all connectors in gas and vapor and light liquid service as... 40 Protection of Environment 11 2014-07-01 2014-07-01 false Connectors in gas and vapor service...
40 CFR 63.168 - Standards: Valves in gas/vapor service and in light liquid service.
Code of Federal Regulations, 2010 CFR
2010-07-01
... § 63.168 Standards: Valves in gas/vapor service and in light liquid service. (a) The provisions of this section apply to valves that are either in gas service or in light liquid service. (1) The provisions are... 40 Protection of Environment 9 2010-07-01 2010-07-01 false Standards: Valves in gas/vapor service...
40 CFR 60.482-11a - Standards: Connectors in gas/vapor service and in light liquid service.
Code of Federal Regulations, 2011 CFR
2011-07-01
...-11a Standards: Connectors in gas/vapor service and in light liquid service. (a) The owner or operator... connectors in gas and vapor and light liquid service as specified in paragraphs (a) and (b)(3) of this... 40 Protection of Environment 6 2011-07-01 2011-07-01 false Standards: Connectors in gas/vapor...
40 CFR 63.168 - Standards: Valves in gas/vapor service and in light liquid service.
Code of Federal Regulations, 2011 CFR
2011-07-01
... § 63.168 Standards: Valves in gas/vapor service and in light liquid service. (a) The provisions of this section apply to valves that are either in gas service or in light liquid service. (1) The provisions are... 40 Protection of Environment 9 2011-07-01 2011-07-01 false Standards: Valves in gas/vapor service...
40 CFR 63.1006 - Valves in gas and vapor service and in light liquid service standards.
Code of Federal Regulations, 2012 CFR
2012-07-01
... § 63.1006 Valves in gas and vapor service and in light liquid service standards. (a) Compliance... requested by the Administrator. For each such demonstration, all valves in gas and vapor and light liquid... 40 Protection of Environment 11 2012-07-01 2012-07-01 false Valves in gas and vapor service and in...
40 CFR 60.482-11a - Standards: Connectors in gas/vapor service and in light liquid service.
Code of Federal Regulations, 2014 CFR
2014-07-01
...-11a Standards: Connectors in gas/vapor service and in light liquid service. (a) The owner or operator... connectors in gas and vapor and light liquid service as specified in paragraphs (a) and (b)(3) of this... 40 Protection of Environment 7 2014-07-01 2014-07-01 false Standards: Connectors in gas/vapor...
40 CFR 63.1027 - Connectors in gas and vapor service and in light liquid service standards.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Standards § 63.1027 Connectors in gas and vapor service and in light liquid service standards. (a..., the owner or operator shall monitor all connectors in gas and vapor and light liquid service as... 40 Protection of Environment 11 2012-07-01 2012-07-01 false Connectors in gas and vapor service...
40 CFR 63.1006 - Valves in gas and vapor service and in light liquid service standards.
Code of Federal Regulations, 2010 CFR
2010-07-01
... § 63.1006 Valves in gas and vapor service and in light liquid service standards. (a) Compliance... requested by the Administrator. For each such demonstration, all valves in gas and vapor and light liquid... 40 Protection of Environment 10 2010-07-01 2010-07-01 false Valves in gas and vapor service and in...
40 CFR 63.1027 - Connectors in gas and vapor service and in light liquid service standards.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Standards § 63.1027 Connectors in gas and vapor service and in light liquid service standards. (a..., the owner or operator shall monitor all connectors in gas and vapor and light liquid service as... 40 Protection of Environment 11 2013-07-01 2013-07-01 false Connectors in gas and vapor service...
40 CFR 63.168 - Standards: Valves in gas/vapor service and in light liquid service.
Code of Federal Regulations, 2013 CFR
2013-07-01
... § 63.168 Standards: Valves in gas/vapor service and in light liquid service. (a) The provisions of this section apply to valves that are either in gas service or in light liquid service. (1) The provisions are... 40 Protection of Environment 10 2013-07-01 2013-07-01 false Standards: Valves in gas/vapor service...
40 CFR 63.168 - Standards: Valves in gas/vapor service and in light liquid service.
Code of Federal Regulations, 2014 CFR
2014-07-01
... § 63.168 Standards: Valves in gas/vapor service and in light liquid service. (a) The provisions of this section apply to valves that are either in gas service or in light liquid service. (1) The provisions are... 40 Protection of Environment 10 2014-07-01 2014-07-01 false Standards: Valves in gas/vapor service...
40 CFR 63.168 - Standards: Valves in gas/vapor service and in light liquid service.
Code of Federal Regulations, 2012 CFR
2012-07-01
... § 63.168 Standards: Valves in gas/vapor service and in light liquid service. (a) The provisions of this section apply to valves that are either in gas service or in light liquid service. (1) The provisions are... 40 Protection of Environment 10 2012-07-01 2012-07-01 false Standards: Valves in gas/vapor service...
46 CFR 197.555 - Personal protective clothing and equipment.
Code of Federal Regulations, 2013 CFR
2013-10-01
... SAFETY AND HEALTH STANDARDS GENERAL PROVISIONS Benzene § 197.555 Personal protective clothing and..., tight-fitting eye goggles to limit dermal exposure to, and prevent eye contact with, liquid benzene. ...
46 CFR 197.555 - Personal protective clothing and equipment.
Code of Federal Regulations, 2012 CFR
2012-10-01
... SAFETY AND HEALTH STANDARDS GENERAL PROVISIONS Benzene § 197.555 Personal protective clothing and..., tight-fitting eye goggles to limit dermal exposure to, and prevent eye contact with, liquid benzene. ...
46 CFR 197.555 - Personal protective clothing and equipment.
Code of Federal Regulations, 2014 CFR
2014-10-01
... SAFETY AND HEALTH STANDARDS GENERAL PROVISIONS Benzene § 197.555 Personal protective clothing and..., tight-fitting eye goggles to limit dermal exposure to, and prevent eye contact with, liquid benzene. ...
Paladin® (Dimethyl Disulfide, DMDS) Fumigant Safe Handling Guide
This liquid pre-plant soil fumigant pesticide poses potential exposure risk concerns, so the product label and Fumigant Management Plan (FMP) address personal protective equipment, air monitoring, and respiratory protection.
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1996-12-31
The project involves the construction of an 80,000 gallons per day (260 TPD) methanol unit utilizing coal-derived synthesis gas from Eastman`s integrated coal gasification facility. The new equipment consists of synthesis gas feed preparation and compression facilities, the liquid phase reactor and auxiliaries, product distillation facilities, and utilities. The technology to be demonstrated is the product of a cooperative development effort by Air Products and DOE in a program that started in 1981. Developed to enhance electric power generation using integrated gasification combined cycle (IGCC) technology, the LPMEOH{trademark} process is ideally suited for directly processing gases produced by modern-day coalmore » gasifiers. This liquid phase process suspends fine catalyst particles in an inert liquid, forming a slurry. The slurry dissipates the heat of the chemical reaction away from the catalyst surface protecting the catalyst and allowing the methanol synthesis reaction to proceed at higher rates. At the Eastman complex, the technology will be integrated with existing coal-gasifiers. A carefully developed test plan will allow operations at Eastman to simulate electricity demand load-following in coal-based IGCC facilities. The operations will also demonstrate the enhanced stability and heat dissipation of the conversion process, its reliable on/off operation, and its ability to produce methanol as a clean liquid fuel without additional upgrading. An off-site product testing program will be conducted to demonstrate the suitability of the methanol product as a transportation fuel and as a fuel for stationary applications for small modular electric power generators for distributed power.« less
40 CFR 264.280 - Closure and post-closure care.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 25 2010-07-01 2010-07-01 false Closure and post-closure care. 264.280 Section 264.280 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES... § 264.278, except that soil-pore liquid monitoring may be terminated 90 days after the last application...
2015-06-07
Field-Portable Gas Chromatograph-Mass Spectrometer.” Forensic Toxicol, 2006, 24, 17-22. Smith, P. “Person-Portable Gas Chromatography : Rapid Temperature...bench-top Gas Chromatograph-Mass Spectrometer (GC-MS) system (ISQ). Nine sites were sampled and analyzed for compounds using Environmental Protection...extraction methods for Liquid Chromatography -MS (LC- MS). Additionally, TD is approximately 1000X more sensitive, requires minimal sample preparation
Stabilized single-injection inactivated polio vaccine elicits a strong neutralizing immune response.
Tzeng, Stephany Y; McHugh, Kevin J; Behrens, Adam M; Rose, Sviatlana; Sugarman, James L; Ferber, Shiran; Langer, Robert; Jaklenec, Ana
2018-05-21
Vaccination in the developing world is hampered by limited patient access, which prevents individuals from receiving the multiple injections necessary for protective immunity. Here, we developed an injectable microparticle formulation of the inactivated polio vaccine (IPV) that releases multiple pulses of stable antigen over time. To accomplish this, we established an IPV stabilization strategy using cationic polymers for pH modulation to enhance traditional small-molecule-based stabilization methods. We investigated the mechanism of this strategy and showed that it was broadly applicable to all three antigens in IPV. Our lead formulations released two bursts of IPV 1 month apart, mimicking a typical vaccination schedule in the developing world. One injection of the controlled-release formulations elicited a similar or better neutralizing response in rats, considered the correlate of protection in humans, than multiple injections of liquid vaccine. This single-administration vaccine strategy has the potential to improve vaccine coverage in the developing world. Copyright © 2018 the Author(s). Published by PNAS.
Stabilized single-injection inactivated polio vaccine elicits a strong neutralizing immune response
Tzeng, Stephany Y.; McHugh, Kevin J.; Behrens, Adam M.; Rose, Sviatlana; Sugarman, James L.; Ferber, Shiran; Jaklenec, Ana
2018-01-01
Vaccination in the developing world is hampered by limited patient access, which prevents individuals from receiving the multiple injections necessary for protective immunity. Here, we developed an injectable microparticle formulation of the inactivated polio vaccine (IPV) that releases multiple pulses of stable antigen over time. To accomplish this, we established an IPV stabilization strategy using cationic polymers for pH modulation to enhance traditional small-molecule–based stabilization methods. We investigated the mechanism of this strategy and showed that it was broadly applicable to all three antigens in IPV. Our lead formulations released two bursts of IPV 1 month apart, mimicking a typical vaccination schedule in the developing world. One injection of the controlled-release formulations elicited a similar or better neutralizing response in rats, considered the correlate of protection in humans, than multiple injections of liquid vaccine. This single-administration vaccine strategy has the potential to improve vaccine coverage in the developing world. PMID:29784798
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 12 2011-07-01 2009-07-01 true Requirements for Wastewater Streams and... of Part 63—Requirements for Wastewater Streams and Liquid Streams in Open Systems Within an MCPU As... wastewater streams and liquid streams in open systems within an MCPU: For each . . . You must . . . 1...
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 13 2013-07-01 2012-07-01 true Requirements for Wastewater Streams and... to Subpart FFFF of Part 63—Requirements for Wastewater Streams and Liquid Streams in Open Systems... applies to your wastewater streams and liquid streams in open systems within an MCPU: For each . . . You...
40 CFR 60.482-7 - Standards: Valves in gas/vapor service and in light liquid service.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Before November 7, 2006 § 60.482-7 Standards: Valves in gas/vapor service and in light liquid service. (a... operation in gas/vapor service or light liquid service after the initial startup date for the process unit... 40 Protection of Environment 6 2011-07-01 2011-07-01 false Standards: Valves in gas/vapor service...
40 CFR 60.482-7 - Standards: Valves in gas/vapor service and in light liquid service.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Before November 7, 2006 § 60.482-7 Standards: Valves in gas/vapor service and in light liquid service. (a... operation in gas/vapor service or light liquid service after the initial startup date for the process unit... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Standards: Valves in gas/vapor service...
40 CFR 60.482-7 - Standards: Valves in gas/vapor service and in light liquid service.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Before November 7, 2006 § 60.482-7 Standards: Valves in gas/vapor service and in light liquid service. (a... operation in gas/vapor service or light liquid service after the initial startup date for the process unit... 40 Protection of Environment 7 2013-07-01 2013-07-01 false Standards: Valves in gas/vapor service...
40 CFR 60.482-7 - Standards: Valves in gas/vapor service and in light liquid service.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Before November 7, 2006 § 60.482-7 Standards: Valves in gas/vapor service and in light liquid service. (a... operation in gas/vapor service or light liquid service after the initial startup date for the process unit... 40 Protection of Environment 7 2014-07-01 2014-07-01 false Standards: Valves in gas/vapor service...
40 CFR 60.482-7 - Standards: Valves in gas/vapor service and in light liquid service.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Before November 7, 2006 § 60.482-7 Standards: Valves in gas/vapor service and in light liquid service. (a... operation in gas/vapor service or light liquid service after the initial startup date for the process unit... 40 Protection of Environment 7 2012-07-01 2012-07-01 false Standards: Valves in gas/vapor service...
30 CFR 75.1107-8 - Fire suppression devices; extinguishant supply systems.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Protection Fire Suppression Devices and Fire-Resistant Hydraulic Fluids on Underground Equipment § 75.1107-8... liquid chemical to protect attended equipment shall: (1) Be maintained at a pressure consistent with the...
30 CFR 75.1107-8 - Fire suppression devices; extinguishant supply systems.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Protection Fire Suppression Devices and Fire-Resistant Hydraulic Fluids on Underground Equipment § 75.1107-8... liquid chemical to protect attended equipment shall: (1) Be maintained at a pressure consistent with the...
Maximum Potential Hydrogen Gas Retention in the sRF Resin Ion Exchange Column for the LAWPS Process
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gauglitz, Phillip A.; Wells, Beric E.; Bottenus, Courtney LH
The Low-Activity Waste Pretreatment System (LAWPS) is being developed to provide treated supernatant liquid from the Hanford tank farms directly to the Low-Activity Waste (LAW) Vitrification Facility at the Hanford Tank Waste Treatment and Immobilization Plant. The design and development of the LAWPS is being conducted by Washington River Protection Solutions, LLC. A key process in LAWPS is the removal of radioactive Cs in ion exchange (IX) columns filled with spherical resorcinol-formaldehyde (sRF) resin. One accident scenario being evaluated is the loss of liquid flow through the sRF resin bed after it has been loaded with radioactive Cs and hydrogenmore » gas is being generated by radiolysis. In normal operations, the generated hydrogen is expected to remain dissolved in the liquid and be continuously removed by liquid flow. For an accident scenario with a loss of flow, hydrogen gas can be retained within the IX column both in the sRF resin and below the bottom screen that supports the resin within the column. The purpose of this report is to summarize calculations that estimate the upper-bound volume of hydrogen gas that can be retained in the column and potentially be released to the headspace of the IX column or to process equipment connected to the IX column and, thus, pose a flammability hazard.« less
Radioactive Liquid Waste Treatment Facility: Environmental Information Document
DOE Office of Scientific and Technical Information (OSTI.GOV)
Haagenstad, H.T.; Gonzales, G.; Suazo, I.L.
1993-11-01
At Los Alamos National Laboratory (LANL), the treatment of radioactive liquid waste is an integral function of the LANL mission: to assure U.S. military deterrence capability through nuclear weapons technology. As part of this mission, LANL conducts nuclear materials research and development (R&D) activities. These activities generate radioactive liquid waste that must be handled in a manner to ensure protection of workers, the public, and the environment. Radioactive liquid waste currently generated at LANL is treated at the Radioactive Liquid Waste Treatment Facility (RLWTF), located at Technical Area (TA)-50. The RLWTF is 30 years old and nearing the end ofmore » its useful design life. The facility was designed at a time when environmental requirements, as well as more effective treatment technologies, were not inherent in engineering design criteria. The evolution of engineering design criteria has resulted in the older technology becoming less effective in treating radioactive liquid wastestreams in accordance with current National Pollutant Discharge Elimination System (NPDES) and Department of Energy (DOE) regulatory requirements. Therefore, to support ongoing R&D programs pertinent to its mission, LANL is in need of capabilities to efficiently treat radioactive liquid waste onsite or to transport the waste off site for treatment and/or disposal. The purpose of the EID is to provide the technical baseline information for subsequent preparation of an Environmental Impact Statement (EIS) for the RLWTF. This EID addresses the proposed action and alternatives for meeting the purpose and need for agency action.« less
Code of Federal Regulations, 2010 CFR
2010-04-01
... 19 Customs Duties 2 2010-04-01 2010-04-01 false Liquidation. 191.105 Section 191.105 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF THE TREASURY (CONTINUED) DRAWBACK Internal Revenue Tax on Flavoring Extracts and Medicinal or Toilet Preparations...
NASA Astrophysics Data System (ADS)
Lazović, Saša; Puač, Nevena; Miletić, Maja; Pavlica, Dušan; Jovanović, Milena; Bugarski, Diana; Mojsilović, Slavko; Maletić, Dejan; Malović, Gordana; Milenković, Pavle; Petrović, Zoran
2010-08-01
In this paper, we study the application of a plasma needle to induce necrosis in planktonic samples containing a single breed of bacteria. Two different types of bacteria, Staphylococcus aureus (ATCC 25923) and Escherichia coli (ATCC 25922), were covered in this study. In all experiments with bacteria, the samples were liquid suspensions of several different concentrations of bacteria prepared according to the McFarland standard. The second system studied in this paper was human peripheral blood mesenchymal stem cells (hPB-MSC). In the case of hPB-MSC, two sets of experiments were performed: when cells were covered with a certain amount of liquid (indirect) and when the cell sample was in direct contact with the plasma. Most importantly, the study is made with the aim to see the effects when the living cells are in a liquid medium, which normally acts as protection against the many agents that may be released by plasmas. It was found that a good effect may be expected for a wide range of initial cell densities and operating conditions causing destruction of several orders of magnitude even under the protection of a liquid. It was established independently that a temperature increase could not affect the cells under the conditions of our experiment, so the effect could originate only from the active species produced by the plasma. In the case of those hPB-MSC that were not protected by a liquid, gas flow proved to produce a considerable effect, presumably due to poor adhesion of the cells, but in a liquid the effect was only due to the plasma. Further optimization of the operation may be attempted, opening up the possibility of localized in vivo sterilization.
Modeling for free surface flow with phase change and its application to fusion technology
NASA Astrophysics Data System (ADS)
Luo, Xiaoyong
The development of predictive capabilities for free surface flow with phase change is essential to evaluate liquid wall protection schemes for various fusion chambers. With inertial fusion energy (IFE) concepts such as HYLIFE-II, rapid condensation into cold liquid surfaces is required when using liquid curtains for protecting reactor walls from blasts and intense neutron radiation. With magnetic fusion energy (MFE) concepts, droplets are injected onto the free surface of the liquid to minimize evaporation by minimizing the surface temperature. This dissertation presents a numerical methodology for free surface flow with phase change to help resolve feasibility issues encountered in the aforementioned fusion engineering fields, especially spray droplet condensation efficiency in IFE and droplet heat transfer enhancement on free surface liquid divertors in MFE. The numerical methodology is being conducted within the framework of the incompressible flow with the phase change model. A new second-order projection method is presented in conjunction with Approximate-Factorization techniques (AF method) for incompressible Navier-Stokes equations. A sub-cell conception is introduced and the Ghost Fluid Method in extended in a modified mass transfer model to accurately calculate the mass transfer across the interface. The Crank-Nicholson method is used for the diffusion term to eliminate the numerical viscous stability restriction. The third-order ENO scheme is used for the convective term to guarantee the accuracy of the method. The level set method is used to capture accurately the free surface of the flow and the deformation of the droplets. This numerical investigation identifies the physics characterizing transient heat and mass transfer of the droplet and the free surface flow. The results show that the numerical methodology is quite successful in modeling the free surface with phase change even though some severe deformations such as breaking and merging occur. The versatility of the numerical methodology shows that the work can easily handle complex physical conditions that occur in the fusion science and engineering.
Mohamed-Ahmed, Abeer H A; Wilson, Matthew P; Albuera, Maedelyn; Chen, Ting; Mills, Philippa B; Footitt, Emma J; Clayton, Peter T; Tuleu, Catherine
2017-04-01
To assess the pyridoxal 5'-phosphate (PLP) content and stability of extemporaneous PLP liquids prepared from dietary supplements used for the treatment of vitamin B 6 -dependent epilepsy. Pyridoxal 5'-phosphate liquids were prepared in accordance with the guidelines given to patients from marketed 50 mg PLP dietary capsules and tablets. The PLP content and its stability were evaluated under conditions resembling the clinical setting using reverse phase HPLC and mass spectrometry. Pyridoxal 5'-phosphate content in most of the extemporaneously prepared liquids from dietary supplements was found to be different from the expected amount (~16-60 mg). Most of these PLP extemporaneous liquids were stable at room temperature (protected from light) after 24 h but unstable after 4 h when exposed to light. A key photodegradation product of PLP in water was confirmed as 4-pyridoxic acid 5'-phosphate (PAP). Pyridoxal 5'-phosphate tablets from Solgar ® were found to be the most reliable product for the preparation of extemporaneous PLP liquids. This work highlighted the difference between the marketed PLP dietary supplements quality and the importance of proper storage of aqueous PLP. There is a need to develop pharmaceutical forms of PLP that ensure dose accuracy and avoid potentially unsafe impurities with the aim of enhancing safety and compliance. © 2017 Royal Pharmaceutical Society.
ADVANCED WORKER PROTECTION SYSTEM
DOE Office of Scientific and Technical Information (OSTI.GOV)
Judson Hedgehock
2001-03-16
From 1993 to 2000, OSS worked under a cost share contract from the Department of Energy (DOE) to develop an Advanced Worker Protection System (AWPS). The AWPS is a protective ensemble that provides the user with both breathing air and cooling for a NIOSH-rated duration of two hours. The ensemble consists of a liquid air based backpack, a Liquid Cooling Garment (LCG), and an outer protective garment. The AWPS project was divided into two phases. During Phase 1, OSS developed and tested a full-scale prototype AWPS. The testing showed that workers using the AWPS could work twice as long asmore » workers using a standard SCBA. The testing also provided performance data on the AWPS in different environments that was used during Phase 2 to optimize the design. During Phase 1, OSS also performed a life-cycle cost analysis on a representative clean up effort. The analysis indicated that the AWPS could save the DOE millions of dollars on D and D activities and improve the health and safety of their workers. During Phase 2, OSS worked to optimize the AWPS design to increase system reliability, to improve system performance and comfort, and to reduce the backpack weight and manufacturing costs. To support this design effort, OSS developed and tested several different generations of prototype units. Two separate successful evaluations of the ensemble were performed by the International Union of Operation Engineers (IUOE). The results of these evaluations were used to drive the design. During Phase 2, OSS also pursued certifying the AWPS with the applicable government agencies. The initial intent during Phase 2 was to finalize the design and then to certify the system. OSS and Scott Health and Safety Products teamed to optimize the AWPS design and then certify the system with the National Institute of Occupational Health and Safety (NIOSH). Unfortunately, technical and programmatic difficulties prevented us from obtaining NIOSH certification. Despite the inability of NIOSH to certify the design, OSS was able to develop and successfully test, in both the lab and in the field, a prototype AWPS. They clearly demonstrated that a system which provides cooling can significantly increase worker productivity by extending the time they can function in a protective garment. They were also able to develop mature outer garment and LCG designs that provide considerable benefits over current protective equipment, such as self donning and doffing, better visibility, and machine washable. A thorough discussion of the activities performed during Phase 1 and Phase 2 is presented in the AWPS Final Report. The report also describes the current system design, outlines the steps needed to certify the AWPS, discusses the technical and programmatic issues that prevented the system from being certified, and presents conclusions and recommendations based upon the seven year effort.« less
33 CFR 151.39 - Operating requirements: Category D NLS.
Code of Federal Regulations, 2014 CFR
2014-07-01
... SECURITY (CONTINUED) POLLUTION VESSELS CARRYING OIL, NOXIOUS LIQUID SUBSTANCES, GARBAGE, MUNICIPAL OR COMMERCIAL WASTE, AND BALLAST WATER Implementation of MARPOL 73/78 and the Protocol on Environmental Protection to the Antarctic Treaty as it Pertains to Pollution from Ships Noxious Liquid Substance Pollution...
33 CFR 151.39 - Operating requirements: Category D NLS.
Code of Federal Regulations, 2013 CFR
2013-07-01
... SECURITY (CONTINUED) POLLUTION VESSELS CARRYING OIL, NOXIOUS LIQUID SUBSTANCES, GARBAGE, MUNICIPAL OR COMMERCIAL WASTE, AND BALLAST WATER Implementation of MARPOL 73/78 and the Protocol on Environmental Protection to the Antarctic Treaty as it Pertains to Pollution from Ships Noxious Liquid Substance Pollution...
33 CFR 151.43 - Control of discharge of NLS residues.
Code of Federal Regulations, 2012 CFR
2012-07-01
... SECURITY (CONTINUED) POLLUTION VESSELS CARRYING OIL, NOXIOUS LIQUID SUBSTANCES, GARBAGE, MUNICIPAL OR COMMERCIAL WASTE, AND BALLAST WATER Implementation of MARPOL 73/78 and the Protocol on Environmental Protection to the Antarctic Treaty as it Pertains to Pollution from Ships Noxious Liquid Substance Pollution...
33 CFR 151.43 - Control of discharge of NLS residues.
Code of Federal Regulations, 2014 CFR
2014-07-01
... SECURITY (CONTINUED) POLLUTION VESSELS CARRYING OIL, NOXIOUS LIQUID SUBSTANCES, GARBAGE, MUNICIPAL OR COMMERCIAL WASTE, AND BALLAST WATER Implementation of MARPOL 73/78 and the Protocol on Environmental Protection to the Antarctic Treaty as it Pertains to Pollution from Ships Noxious Liquid Substance Pollution...
33 CFR 151.43 - Control of discharge of NLS residues.
Code of Federal Regulations, 2013 CFR
2013-07-01
... SECURITY (CONTINUED) POLLUTION VESSELS CARRYING OIL, NOXIOUS LIQUID SUBSTANCES, GARBAGE, MUNICIPAL OR COMMERCIAL WASTE, AND BALLAST WATER Implementation of MARPOL 73/78 and the Protocol on Environmental Protection to the Antarctic Treaty as it Pertains to Pollution from Ships Noxious Liquid Substance Pollution...
33 CFR 151.43 - Control of discharge of NLS residues.
Code of Federal Regulations, 2011 CFR
2011-07-01
... SECURITY (CONTINUED) POLLUTION VESSELS CARRYING OIL, NOXIOUS LIQUID SUBSTANCES, GARBAGE, MUNICIPAL OR COMMERCIAL WASTE, AND BALLAST WATER Implementation of MARPOL 73/78 and the Protocol on Environmental Protection to the Antarctic Treaty as it Pertains to Pollution from Ships Noxious Liquid Substance Pollution...
33 CFR 151.39 - Operating requirements: Category D NLS.
Code of Federal Regulations, 2011 CFR
2011-07-01
... SECURITY (CONTINUED) POLLUTION VESSELS CARRYING OIL, NOXIOUS LIQUID SUBSTANCES, GARBAGE, MUNICIPAL OR COMMERCIAL WASTE, AND BALLAST WATER Implementation of MARPOL 73/78 and the Protocol on Environmental Protection to the Antarctic Treaty as it Pertains to Pollution from Ships Noxious Liquid Substance Pollution...
33 CFR 151.39 - Operating requirements: Category D NLS.
Code of Federal Regulations, 2012 CFR
2012-07-01
... SECURITY (CONTINUED) POLLUTION VESSELS CARRYING OIL, NOXIOUS LIQUID SUBSTANCES, GARBAGE, MUNICIPAL OR COMMERCIAL WASTE, AND BALLAST WATER Implementation of MARPOL 73/78 and the Protocol on Environmental Protection to the Antarctic Treaty as it Pertains to Pollution from Ships Noxious Liquid Substance Pollution...
33 CFR 151.39 - Operating requirements: Category D NLS.
Code of Federal Regulations, 2010 CFR
2010-07-01
... SECURITY (CONTINUED) POLLUTION VESSELS CARRYING OIL, NOXIOUS LIQUID SUBSTANCES, GARBAGE, MUNICIPAL OR COMMERCIAL WASTE, AND BALLAST WATER Implementation of MARPOL 73/78 and the Protocol on Environmental Protection to the Antarctic Treaty as it Pertains to Pollution from Ships Noxious Liquid Substance Pollution...
33 CFR 151.43 - Control of discharge of NLS residues.
Code of Federal Regulations, 2010 CFR
2010-07-01
... SECURITY (CONTINUED) POLLUTION VESSELS CARRYING OIL, NOXIOUS LIQUID SUBSTANCES, GARBAGE, MUNICIPAL OR COMMERCIAL WASTE, AND BALLAST WATER Implementation of MARPOL 73/78 and the Protocol on Environmental Protection to the Antarctic Treaty as it Pertains to Pollution from Ships Noxious Liquid Substance Pollution...
Photon energy upconverting nanopaper: a bioinspired oxygen protection strategy.
Svagan, Anna J; Busko, Dmitry; Avlasevich, Yuri; Glasser, Gunnar; Baluschev, Stanislav; Landfester, Katharina
2014-08-26
The development of solid materials which are able to upconvert optical radiation into photons of higher energy is attractive for many applications such as photocatalytic cells and photovoltaic devices. However, to fully exploit triplet-triplet annihilation photon energy upconversion (TTA-UC), oxygen protection is imperative because molecular oxygen is an ultimate quencher of the photon upconversion process. So far, reported solid TTA-UC materials have focused mainly on elastomeric matrices with low barrier properties because the TTA-UC efficiency generally drops significantly in glassy and semicrystalline matrices. To overcome this limit, for example, combine effective and sustainable annihilation upconversion with exhaustive oxygen protection of dyes, we prepare a sustainable solid-state-like material based on nanocellulose. Inspired by the structural buildup of leaves in Nature, we compartmentalize the dyes in the liquid core of nanocellulose-based capsules which are then further embedded in a cellulose nanofibers (NFC) matrix. Using pristine cellulose nanofibers, a sustainable and environmentally friendly functional nanomaterial with ultrahigh barrier properties is achieved. Also, an ensemble of sensitizers and emitter compounds are encapsulated, which allow harvesting of the energy of the whole deep-red sunlight region. The films demonstrate excellent lifetime in synthetic air (20.5/79.5, O2/N2)-even after 1 h operation, the intensity of the TTA-UC signal decreased only 7.8% for the film with 8.8 μm thick NFC coating. The lifetime can be further modulated by the thickness of the protective NFC coating. For comparison, the lifetime of TTA-UC in liquids exposed to air is on the level of seconds to minutes due to fast oxygen quenching.
Monitoring gross alpha and beta activity in liquids by using ZnS(Ag) scintillation detectors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stevanato, L.; Cester, D.; Filippi, D.
In this work the possibility of monitoring gross alpha and beta activity in liquids using EJ-444 was investigated. Specific tests were carried out to determine the change of the detector properties in water tests. Possible protecting coating is also proposed and tested. Alpha/beta real-time monitoring in liquids is a goal of the EU project TAWARA{sub R}TM. (authors)
Campbell, Gossett A; Vallejo, Erick
2015-01-01
The packaging presentation of oral liquid pediatric medicines is a critical step in maintaining chemical and physical stability, compliance, adherence, and proper handling by the target patient population, guardians, caregivers, and health-care professionals. The common packaging presentations for commercial oral liquid pediatric drug products are glass bottle, plastic bottle, sachet, and stick pack configurations. The type of pack presentation selected is driven by the quality target product profile (QTPP) that is designed around the physicochemical properties of the drug substance and the desired drug product suitability for the target population. The QTPP defines the intended use of the drug product, drug product quality criteria, dose strength, dosage form, container closure system, storage conditions, stability criteria, dosing device, shelf life, and attributes affecting the pharmacokinetic characteristics. Oral liquid pediatric formulations are typically prepared from a powder that is constituted at the time of use as a suspension or a solution for single or multiple use depending on the stability of the constituted formulation. Active ingredients with high aqueous solubility can be developed as a powder for oral solution and presented in a bottle for multiple use product and a stick pack, packet, or sachet for single-use product. Active ingredients with low aqueous solubility can be developed as a powder for oral suspension and presented in a bottle for multiple use product and a stick pack or sachet for single-use product. A secondary package may be used in cases where the primary pack failed to provide adequate protection against light degradation. This work will help formulation scientists select the most appropriate pack presentation in the early stages of pediatric clinical development. © 2014 Wiley Periodicals, Inc. and the American Pharmacists Association.
Advanced Coating Removal Techniques
NASA Technical Reports Server (NTRS)
Seibert, Jon
2006-01-01
An important step in the repair and protection against corrosion damage is the safe removal of the oxidation and protective coatings without further damaging the integrity of the substrate. Two such methods that are proving to be safe and effective in this task are liquid nitrogen and laser removal operations. Laser technology used for the removal of protective coatings is currently being researched and implemented in various areas of the aerospace industry. Delivering thousands of focused energy pulses, the laser ablates the coating surface by heating and dissolving the material applied to the substrate. The metal substrate will reflect the laser and redirect the energy to any remaining protective coating, thus preventing any collateral damage the substrate may suffer throughout the process. Liquid nitrogen jets are comparable to blasting with an ultra high-pressure water jet but without the residual liquid that requires collection and removal .As the liquid nitrogen reaches the surface it is transformed into gaseous nitrogen and reenters the atmosphere without any contamination to surrounding hardware. These innovative technologies simplify corrosion repair by eliminating hazardous chemicals and repetitive manual labor from the coating removal process. One very significant advantage is the reduction of particulate contamination exposure to personnel. With the removal of coatings adjacent to sensitive flight hardware, a benefit of each technique for the space program is that no contamination such as beads, water, or sanding residue is left behind when the job is finished. One primary concern is the safe removal of coatings from thin aluminum honeycomb face sheet. NASA recently conducted thermal testing on liquid nitrogen systems and found that no damage occurred on 1/6", aluminum substrates. Wright Patterson Air Force Base in conjunction with Boeing and NASA is currently testing the laser remOval technique for process qualification. Other applications of liquid nitrogen operations include cutting of both soft and hard materials. While the laser will not cut materials, it can be used to roughen surfaces and to remove other materials from the substrate including oil, grease, and mold. The space program can benefit from several of these applications with the need for precise removal of coatings and other organic compounds in areas adjacent to sensitive space flight hardware. Significant advantages are evident when comparing liquid nitrogen and laser removal operations over current techniques of media blasting and sanding.
Spraylon fluorocarbon encapsulation for silicon solar cell arrays
NASA Technical Reports Server (NTRS)
1977-01-01
A development program was performed for evaluating, modifying, and optimizing the Lockheed formulated liquid transparent filmforming Spraylon fluorocarbon protective coating for silicon solar cells and modules. The program objectives were designed to meet the requirements of the low-cost automated solar cell array fabrication process. As part of the study, a computer program was used to establish the limits of the safe working stress in the coated silicon solar cell array system under severe thermal shock.
All-optical liquid crystal spatial light modulators
NASA Astrophysics Data System (ADS)
Tabiryan, Nelson; Grozhik, Vladimir; Khoo, Iam Choon; Nersisyan, Sarik R.; Serak, Svetlana
2003-12-01
Nonlinear optical processes in liquid crystals (LC) can be used for construction of all-optical spatial light modulators (SLM) where the photosensitivity and phase modulating functions are integrated into a single layer of an LC-material. Such spatial light integrated modulators (SLIMs) cost only a fraction of the conventional LC-SLM and can be used with high power laser radiation due to high transparency of LC materials and absence of light absorbing electrodes on the substrates of the LC-cell constituting the SLIM. Recent development of LC materials the photosensitivity of which is comparable to that of semiconductors has led to using SLIM in schemes of optical anti-jamming, sensor protection, and image processing. All-optical processes add remarkable versatility to the operation of SLIM harnessing the wealth inherent to light-matter interaction phenomena.
Afkhami, Abbas; Khoshsafar, Hosein; Bagheri, Hasan; Madrakian, Tayyebeh
2014-02-01
A simple, highly sensitive and selective carbon nanocomposite electrode has been developed for the electrochemical trace determination of cadmium. This sensor was designed by incorporation of multi-walled carbon nanotubes (MWCNTs) and a new synthesized Schiff base into the carbon paste ionic liquid electrode (CPE(IL)) which provides remarkably improved sensitivity and selectivity for the electrochemical stripping assay of Cd(II). The detection limit of the method was found to be 0.08 μg L(-1) (S/N=3) that is lower than the maximum contaminant level of Cd(II) allowed by the Environmental Protection Agency (EPA) in standard drinking waters. The proposed electrode exhibits good applicability for monitoring Cd(II) in various real samples. © 2013.
History of the Development of Liquid-Applied Coatings for Protection of Reinforced Concrete
NASA Technical Reports Server (NTRS)
Curran, Joseph J.; Hansen, marlin H.
2005-01-01
Corrosion of reinforcing steel in concrete is an insidious problem for structures at Kennedy Space Center (KSC). KSC is located on the coast of Florida in a highly corrosive atmosphere. Launch pads, highway bridge infrastructure, and buildings are strongly affected. To mitigate these problems, NASA initiated a development program for a Galvanic Liquid-Applied Coating System (GLACS). A breakthrough in this area would have great commercial value in transportation, marine and construction industry infrastructures. The patented NASA GLACS system has undergone considerable testing to meet the needs of commercialization. A moisture-cure coating gives excellent adhesion with ease of application compared to existing galvanic products on the market. The latest development, GalvaCori; can be sprayed or hand applied to almost any structure shape. A self-adhesive conductive tape system has been devised to simplify current collection within the coating areas. In testing programs, millivolt potential and milliamp output per square foot of anode have been closely studied at actual test sites. These two parameters are probably the most challenging items of a resin-based, room-temperature-applied, galvanic coating. Extensive re-formulation has resulted in a system that provides the needed polarization for catholic protection of reinforcing steel in concrete in a variety of structure environments. The rate of corrosion of rebar in concrete is greatly affected by the environment of the structure. In addition to this, for any given concrete structure; moisture level, carbonization, and chloride contamination influences the rate of rebar corrosion. Similarly, the cathodic protection level of galvanic systems is also dependent on the moisture level of the concrete. GalvaCorr is formulated to maintain galvanic activity as the moisture level of the structure declines. GalvaCorr is available as a three-part kit. The mixing step requires about ten minutes. The viscosity can be easily adjusted to meet the application needs. The pot or working life is four to six hours, depending on the temperature. GalvaCorr can be thought of as a spray-on coating, battery ready to provide up to -1.4 volts (relative to CSE) of cathodic protection (CP) potential.
40 CFR 63.2390 - What records must I keep?
Code of Federal Regulations, 2011 CFR
2011-07-01
... Section 63.2390 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR SOURCE CATEGORIES National Emission Standards for Hazardous Air Pollutants: Organic Liquids Distribution (Non-Gasoline) Notifications, Reports...
Code of Federal Regulations, 2010 CFR
2010-04-01
... 19 Customs Duties 2 2010-04-01 2010-04-01 false Liquidation. 191.167 Section 191.167 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF THE TREASURY (CONTINUED) DRAWBACK Distilled Spirits, Wines, or Beer Which Are Unmerchantable or Do Not Conform to Sample...
33 CFR 151.32 - Special areas for the purpose of Annex II.
Code of Federal Regulations, 2013 CFR
2013-07-01
... SECURITY (CONTINUED) POLLUTION VESSELS CARRYING OIL, NOXIOUS LIQUID SUBSTANCES, GARBAGE, MUNICIPAL OR COMMERCIAL WASTE, AND BALLAST WATER Implementation of MARPOL 73/78 and the Protocol on Environmental Protection to the Antarctic Treaty as it Pertains to Pollution from Ships Noxious Liquid Substance Pollution...
Code of Federal Regulations, 2013 CFR
2013-04-01
... 19 Customs Duties 2 2013-04-01 2013-04-01 false Liquidation. 191.167 Section 191.167 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF THE TREASURY (CONTINUED) DRAWBACK Distilled Spirits, Wines, or Beer Which Are Unmerchantable or Do Not Conform to Sample...
Code of Federal Regulations, 2014 CFR
2014-07-01
... following definitions apply in this subpart. Blasting agent. Any substance classified as a blasting agent by... by a liquid to form a flammable vapor-air mixture near the surface of the liquid. Igniter cord. A... initiate other explosives or blasting agents. Safety switch. A switch that provides shunt protection in...
Code of Federal Regulations, 2013 CFR
2013-07-01
... following definitions apply in this subpart. Blasting agent. Any substance classified as a blasting agent by... by a liquid to form a flammable vapor-air mixture near the surface of the liquid. Igniter cord. A... initiate other explosives or blasting agents. Safety switch. A switch that provides shunt protection in...
Code of Federal Regulations, 2011 CFR
2011-07-01
... following definitions apply in this subpart. Blasting agent. Any substance classified as a blasting agent by... by a liquid to form a flammable vapor-air mixture near the surface of the liquid. Igniter cord. A... initiate other explosives or blasting agents. Safety switch. A switch that provides shunt protection in...
33 CFR 151.32 - Special areas for the purpose of Annex II.
Code of Federal Regulations, 2012 CFR
2012-07-01
... SECURITY (CONTINUED) POLLUTION VESSELS CARRYING OIL, NOXIOUS LIQUID SUBSTANCES, GARBAGE, MUNICIPAL OR COMMERCIAL WASTE, AND BALLAST WATER Implementation of MARPOL 73/78 and the Protocol on Environmental Protection to the Antarctic Treaty as it Pertains to Pollution from Ships Noxious Liquid Substance Pollution...
33 CFR 151.32 - Special areas for the purpose of Annex II.
Code of Federal Regulations, 2014 CFR
2014-07-01
... SECURITY (CONTINUED) POLLUTION VESSELS CARRYING OIL, NOXIOUS LIQUID SUBSTANCES, GARBAGE, MUNICIPAL OR COMMERCIAL WASTE, AND BALLAST WATER Implementation of MARPOL 73/78 and the Protocol on Environmental Protection to the Antarctic Treaty as it Pertains to Pollution from Ships Noxious Liquid Substance Pollution...
33 CFR 151.32 - Special areas for the purpose of Annex II.
Code of Federal Regulations, 2011 CFR
2011-07-01
... SECURITY (CONTINUED) POLLUTION VESSELS CARRYING OIL, NOXIOUS LIQUID SUBSTANCES, GARBAGE, MUNICIPAL OR COMMERCIAL WASTE, AND BALLAST WATER Implementation of MARPOL 73/78 and the Protocol on Environmental Protection to the Antarctic Treaty as it Pertains to Pollution from Ships Noxious Liquid Substance Pollution...
33 CFR 151.32 - Special areas for the purpose of Annex II.
Code of Federal Regulations, 2010 CFR
2010-07-01
... SECURITY (CONTINUED) POLLUTION VESSELS CARRYING OIL, NOXIOUS LIQUID SUBSTANCES, GARBAGE, MUNICIPAL OR COMMERCIAL WASTE, AND BALLAST WATER Implementation of MARPOL 73/78 and the Protocol on Environmental Protection to the Antarctic Treaty as it Pertains to Pollution from Ships Noxious Liquid Substance Pollution...
Liquid and Gaseous Waste Operations Department annual operating report CY 1996
DOE Office of Scientific and Technical Information (OSTI.GOV)
Maddox, J.J.; Scott, C.B.
1997-03-01
This annual report summarizes operating activities dealing with the process waste system, the liquid low-level waste system, and the gaseous waste system. It also describes upgrade activities dealing with the process and liquid low-level waste systems, the cathodic protection system, a stack ventilation system, and configuration control. Maintenance activities are described dealing with nonradiological wastewater treatment plant, process waste treatment plant and collection system, liquid low-level waste system, and gaseous waste system. Miscellaneous activities include training, audits/reviews/tours, and environmental restoration support.
Compact high-sensitivity potentiometer for detection of low ion concentrations in liquids
NASA Astrophysics Data System (ADS)
Balevicius, Z.; Lescinskas, R.; Celiesiute, R.; Stirke, A.; Balevicius, S.; Kersulis, S.; Bleizgys, V.; Maciuleviciene, R.; Ramanavicius, A.; Zurauskiene, N.
2018-04-01
The compact potentiometer, based on an electronic circuit protected from electrostatic and electromagnetic interference, was developed for the measurement of low ion concentrations in liquids. The electronic circuit of the potentiometer, consisting of analogous and digital parts, enables the measurement of fA currents. This makes it possible to perform reliable measurements of ion concentrations in liquids that are as small as 10-8-10-7M. The instrument was tested using electrodes that were selective for tetraphenylphosphonium (TPP+) ions. It was demonstrated that the characteristic response time of the potentiometer electronic circuit to changes in the concentration of these ions in a liquid was in the order of 10 s. An investigation of TPP+ absorption by baker yeast has shown that this device can be successfully used for long term (several hours) measurements with zero signal drift, which was about 1 μV/s. Finally, due to the small dimensions of the electronic circuit (7.5 × 2 × 1.5 cm), this potentiometer can be easily installed at a large apparatus in the laboratory condition (≈25 °C), such as high pulsed electrical generators of magnetic fields that are used in electroporation studies of biological cells.
González, Alba; Avivar, Jessica; Cerdà, Víctor
2015-09-25
A new procedure for the extraction, preconcentration and simultaneous determination of the estrogens most used in contraception pharmaceuticals (estrone, 17β-estradiol, estriol, and 17α-ethynylestradiol), cataloged as Contaminants of Emergent Concern by the Environmental Protection Agency of the United States (US-EPA), is proposed. The developed system performs an in-syringe magnetic stirring-assisted dispersive liquid-liquid microextraction (in-syringe-MSA-DLLME) prior derivatization and gas chromatography (GC-MS). Different extraction (carbon tetrachloride, ethyl acetate, chloroform and trichloroethylene) and disperser solvents (acetone, acetonitrile and methanol) were tested. Chloroform and acetone were chosen as extraction and disperser solvent, respectively, as they provided the best extraction efficiency. Then, a multivariate optimization of the extraction conditions was carried out. Derivatization conditions were also studied to ensure the conversion of the estrogens to their respective trimethylsilyl derivatives. Low LODs and LOQs were achieved, i.e. between 11 and 82ngL(-1), and 37 and 272ngL(-1), respectively. Good values for intra and inter-day precision were obtained (RSDs≤7.06% and RSD≤7.11%, respectively). The method was successfully applied to wastewater samples. Copyright © 2015 Elsevier B.V. All rights reserved.
Hexavalent Chromium IV-Free Primer Development
NASA Technical Reports Server (NTRS)
Alldredge, Michael J.; Buck, Amy L.
2015-01-01
Primer materials provide corrosion protection for metal parts as well as an increased adhesion between metallic substrates and thermal protection systems (TPSs). Current primers for use in cryogenic applications contain hexavalent chromium. This hexavalent chromium provides excellent corrosion protection even in a cryogenic environment, but it is a carcinogen that requires special equipment and waste control procedures to use. The hazardous nature of hexavalent chromium makes it an obsolescence risk in the future. This study included two phases of evaluation. Thirteen primers were initially identified as candidates and twelve of those primers were tested in phase 1. Four of the best performing candidates from phase 1 continued into phase 2 testing. Phase 1 testing consisted mostly of liquid constituent and physical property testing. Cryoflex and salt fog testing were included in phase 1 because of their importance to the overall success of a candidate material. Phase 2 consisted of physical, thermal, and mechanical properties for nominally processed and fabricated specimens.
Cold flame on Biofilm - Transport of Plasma Chemistry from Gas to Liquid Phase
NASA Astrophysics Data System (ADS)
Kong, Michael
2014-10-01
One of the most active and fastest growing fields in low-temperature plasma science today is biological effects of gas plasmas and their translation in many challenges of societal importance such as healthcare, environment, agriculture, and nanoscale fabrication and synthesis. Using medicine as an example, there are already three FDA-approved plasma-based surgical procedures for tissue ablation and blood coagulation and at least five phase-II clinical trials on plasma-assisted wound healing therapies. A key driver for realizing the immense application potential of near room-temperature ambient pressure gas plasmas, commonly known as cold atmospheric plasmas or CAP, is to build a sizeable interdisciplinary knowledge base with which to unravel, optimize, and indeed design how reactive plasma species interact with cells and their key components such as protein and DNA. Whilst a logical objective, it is a formidable challenge not least since existing knowledge of gas discharges is largely in the gas-phase and therefore not directly applicable to cell-containing matters that are covered by or embedded in liquid (e.g. biofluid). Here, we study plasma inactivation of biofilms, a jelly-like structure that bacteria use to protect themselves and a major source of antimicrobial resistance. As 60--90% of biofilm is made of water, we develop a holistic model incorporating physics and chemistry in the upstream CAP-generating region, a plasma-exit region as a buffer for as-phase transport, and a downstream liquid region bordering the gas buffer region. A special model is developed to account for rapid chemical reactions accompanied the transport of gas-phase plasma species through the gas-liquid interface and for liquid-phase chemical reactions. Numerical simulation is used to illustrate how key reactive oxygen species (ROS) are transported into the liquid, and this is supported with experimental data of both biofilm inactivation using plasmas and electron spin spectroscopy (ESR) measurement of liquid-phase ROS.
Controlling Surface Chemistry of Gallium Liquid Metal Alloys to Enhance their Fluidic Properties
NASA Astrophysics Data System (ADS)
Ilyas, Nahid; Cumby, Brad; Cook, Alexander; Durstock, Michael; Tabor, Christopher; Materials; Manufacturing Directorate Team
Gallium liquid metal alloys (GaLMAs) are one of the key components of emerging technologies in reconfigurable electronics, such as tunable radio frequency antennas and electronic switches. Reversible flow of GaLMA in microchannels of these types of devices is hindered by the instantaneous formation of its oxide skin in ambient environment. The oxide film sticks to most surfaces leaving unwanted metallic residues that can cause undesired electronic properties. In this report, residue-free reversible flow of a binary alloy of gallium (eutectic gallium indium) is demonstrated via two types of surface modifications where the oxide film is either protected by an organic thin film or chemically removed. An interface modification layer (alkyl phosphonic acids) was introduced into the microfluidic system to modify the liquid metal surface and protect its oxide layer. Alternatively, an ion exchange membrane was utilized as a 'sponge-like' channel material to store and slowly release small amounts of HCl to react with the surface oxide of the liquid metal. Characterization of these interfaces at molecular level by surface spectroscopy and microscopy provided with mechanistic details for the interfacial interactions between the liquid metal surface and the channel materials.
Transpiration-Cooled Spacecraft-Insulation-Repair Fasteners
NASA Technical Reports Server (NTRS)
Camarda, Charles J.; Pettit, Donald R.; Glass, David; Scotti, Stephen J.; Vaughn, Wallace Lee; Rawal, Suraj
2012-01-01
Transpiration-cooled fasteners are proposed that operate like an open-loop heat pipe (self-tapping screws, bolts, and spikes) for use in on-orbit repair of thermal- insulation of a space shuttle or other spacecraft. By limiting the temperature rise of such a fastener and of the adjacent repair material and thermal protection system, the transpiration cooling would contribute to the ability of the repair to retain its strength and integrity in the high-heat-flux, oxidizing environment of reentry into the atmosphere of the Earth. A typical fastener according to the proposal would include a hollow refractory-metal, refractory-composite, or ceramic screw or bolt, the central cavity of which would be occupied by a porous refractory- metal or ceramic plug that would act as both a reservoir and a wick for a transpirant liquid. The plug dimensions, the plug material, and the sizes of the pores would be chosen in conjunction with the transpirant liquid so that (1) capillary pumping could be relied upon to transport the liquid to the heated surface, where the liquid would be vaporized, and (2) the amount of liquid would suffice for protecting against the anticipated heat flux and integrated heat load.
Fagan, Pebbles; Pokhrel, Pallav; Herzog, Thaddeus A; Guy, Mignonne C; Sakuma, Kari-Lyn K; Trinidad, Dennis R; Cassel, Kevin; Jorgensen, Dorothy; Lynch, Tania; Felicitas-Perkins, Jamie Q; Palafox, Sherilyn; Hamamura, Faith; Maloney, Sarah; Degree, Kaylah; Sterling, Kymberle; Moolchan, Eric; Clanton, Mark S; Eissenberg, Thomas
2017-05-18
Prior to the Food and Drug Administration's (FDA) regulation of electronic cigarettes and warning statements related to nicotine addiction, there was no critical examination of manufacturer/distributor voluntary practices that could potentially inform FDA actions aimed to protect consumers. This study examined the content of warning statements and safety characteristics of electronic cigarette liquid bottles using a national sample. Research staff randomly selected four electronic cigarette liquid manufacturers/distributors from four U.S. geographic regions. Staff documented the characteristics of product packaging and content of warning statements on 147 electronic cigarette liquids (0-30 mg/ml of nicotine) purchased online from 16 manufacturers/distributors in April of 2016. Data showed that 97.9% of the electronic cigarette liquid bottles included a warning statement, most of which focused on nicotine exposure rather than health. Only 22.4% of bottles used a warning statement that indicated the product "contained nicotine". Of bottles that advertised a nicotine-based concentration of 12 mg/ml, 26% had a warning statements stated that the product "contains nicotine". None of the statements that indicated that the product "contained nicotine" stated that nicotine was "addictive". All bottles had a safety cap and 12% were in plastic shrink-wrap. Fifty-six percent of the websites had a minimum age requirement barrier that prevented under-aged persons from entering. Most manufacturers/distributors printed a warning statement on electronic cigarette liquid bottles, but avoided warning consumers about the presence and the addictiveness of nicotine. Studies are needed to examine manufacturer/distributor modifications to product packaging and how packaging affects consumer behaviors. These data can inform future FDA requirements related to the packaging and advertising of e-cigarette liquids; regulation related to the content of warning statements, including exposure warning statements, which are not currently mandated; and requirements on websites or language on packaging to help manufacturers adhere to the minimum age of purchase regulation. The data can also be used to help FDA develop additional guidance on the framing of statements on packaging that helps consumers make informed decisions about purchasing the product or protecting young people from use or unintentional exposure to the product. © The Author 2017. Published by Oxford University Press on behalf of the Society for Research on Nicotine and Tobacco. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Josephson, J.; Sowa, E.S.
1977-04-01
The design and testing of a simple and reliable Self-Actuated Shutdown System (SASS) for the protection of Liquid Metal Fast Breeder Reactors (LMFBRs) is described. A ferromagnetic Curie temperature permanent magnet holding device has been selected for the design of the Self-Actuated Shutdown System in order to enhance the safety of liquid metal cooled fast reactors (LMFBRs). The self-actuated, self-contained device operates such that accident conditions, resulting in increased coolant temperature or neutron flux reduce the magnetic holding force suspending a neutron absorber above the core by raising the temperature of the trigger mechanism above the Curie point. Neutron absorbermore » material is then inserted into the core, under gravity, terminating the accident. Two possible design variations of the selected concept are presented.« less
17 CFR 270.22e-3 - Exemption for liquidation of money market funds.
Code of Federal Regulations, 2010 CFR
2010-04-01
... for liquidation of money market funds. (a) Exemption. A registered open-end management investment... of the Division of Investment Management or the Director's designee. (b) Conduits. Any registered... Division of Investment Management or the Director's designee. (c) Commission orders. For the protection of...
46 CFR 28.380 - General structural fire protection.
Code of Federal Regulations, 2012 CFR
2012-10-01
... and a machinery or a fuel tank storage space must be sealed. (d) Paint and flammable liquid lockers... combustible liquids or vapors are present, e.g., machinery spaces and paint lockers, a vapor barrier which...-1. (c) Separation of machinery and fuel tank spaces from accommodation spaces. (1) Each...
46 CFR 28.380 - General structural fire protection.
Code of Federal Regulations, 2011 CFR
2011-10-01
... and a machinery or a fuel tank storage space must be sealed. (d) Paint and flammable liquid lockers... combustible liquids or vapors are present, e.g., machinery spaces and paint lockers, a vapor barrier which...-1. (c) Separation of machinery and fuel tank spaces from accommodation spaces. (1) Each...
46 CFR 28.380 - General structural fire protection.
Code of Federal Regulations, 2013 CFR
2013-10-01
... and a machinery or a fuel tank storage space must be sealed. (d) Paint and flammable liquid lockers... combustible liquids or vapors are present, e.g., machinery spaces and paint lockers, a vapor barrier which...-1. (c) Separation of machinery and fuel tank spaces from accommodation spaces. (1) Each...
46 CFR 28.380 - General structural fire protection.
Code of Federal Regulations, 2014 CFR
2014-10-01
... and a machinery or a fuel tank storage space must be sealed. (d) Paint and flammable liquid lockers... combustible liquids or vapors are present, e.g., machinery spaces and paint lockers, a vapor barrier which...-1. (c) Separation of machinery and fuel tank spaces from accommodation spaces. (1) Each...
33 CFR 151.49 - Category C and D Oil-like NLSs allowed for carriage.
Code of Federal Regulations, 2012 CFR
2012-07-01
... HOMELAND SECURITY (CONTINUED) POLLUTION VESSELS CARRYING OIL, NOXIOUS LIQUID SUBSTANCES, GARBAGE, MUNICIPAL OR COMMERCIAL WASTE, AND BALLAST WATER Implementation of MARPOL 73/78 and the Protocol on Environmental Protection to the Antarctic Treaty as it Pertains to Pollution from Ships Noxious Liquid Substance...
33 CFR 151.49 - Category C and D Oil-like NLSs allowed for carriage.
Code of Federal Regulations, 2011 CFR
2011-07-01
... HOMELAND SECURITY (CONTINUED) POLLUTION VESSELS CARRYING OIL, NOXIOUS LIQUID SUBSTANCES, GARBAGE, MUNICIPAL OR COMMERCIAL WASTE, AND BALLAST WATER Implementation of MARPOL 73/78 and the Protocol on Environmental Protection to the Antarctic Treaty as it Pertains to Pollution from Ships Noxious Liquid Substance...
33 CFR 151.49 - Category C and D Oil-like NLSs allowed for carriage.
Code of Federal Regulations, 2014 CFR
2014-07-01
... HOMELAND SECURITY (CONTINUED) POLLUTION VESSELS CARRYING OIL, NOXIOUS LIQUID SUBSTANCES, GARBAGE, MUNICIPAL OR COMMERCIAL WASTE, AND BALLAST WATER Implementation of MARPOL 73/78 and the Protocol on Environmental Protection to the Antarctic Treaty as it Pertains to Pollution from Ships Noxious Liquid Substance...
33 CFR 151.33 - Certificates needed to carry Category C Oil-like NLS.
Code of Federal Regulations, 2012 CFR
2012-07-01
... HOMELAND SECURITY (CONTINUED) POLLUTION VESSELS CARRYING OIL, NOXIOUS LIQUID SUBSTANCES, GARBAGE, MUNICIPAL OR COMMERCIAL WASTE, AND BALLAST WATER Implementation of MARPOL 73/78 and the Protocol on Environmental Protection to the Antarctic Treaty as it Pertains to Pollution from Ships Noxious Liquid Substance...
33 CFR 151.33 - Certificates needed to carry Category C Oil-like NLS.
Code of Federal Regulations, 2014 CFR
2014-07-01
... HOMELAND SECURITY (CONTINUED) POLLUTION VESSELS CARRYING OIL, NOXIOUS LIQUID SUBSTANCES, GARBAGE, MUNICIPAL OR COMMERCIAL WASTE, AND BALLAST WATER Implementation of MARPOL 73/78 and the Protocol on Environmental Protection to the Antarctic Treaty as it Pertains to Pollution from Ships Noxious Liquid Substance...
33 CFR 151.49 - Category C and D Oil-like NLSs allowed for carriage.
Code of Federal Regulations, 2013 CFR
2013-07-01
... HOMELAND SECURITY (CONTINUED) POLLUTION VESSELS CARRYING OIL, NOXIOUS LIQUID SUBSTANCES, GARBAGE, MUNICIPAL OR COMMERCIAL WASTE, AND BALLAST WATER Implementation of MARPOL 73/78 and the Protocol on Environmental Protection to the Antarctic Treaty as it Pertains to Pollution from Ships Noxious Liquid Substance...
33 CFR 151.33 - Certificates needed to carry Category C Oil-like NLS.
Code of Federal Regulations, 2011 CFR
2011-07-01
... HOMELAND SECURITY (CONTINUED) POLLUTION VESSELS CARRYING OIL, NOXIOUS LIQUID SUBSTANCES, GARBAGE, MUNICIPAL OR COMMERCIAL WASTE, AND BALLAST WATER Implementation of MARPOL 73/78 and the Protocol on Environmental Protection to the Antarctic Treaty as it Pertains to Pollution from Ships Noxious Liquid Substance...
19 CFR 162.80 - Liability for duties; liquidation of entries.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 19 Customs Duties 2 2010-04-01 2010-04-01 false Liability for duties; liquidation of entries. 162.80 Section 162.80 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF THE TREASURY (CONTINUED) INSPECTION, SEARCH, AND SEIZURE Special Procedures for Certain...
19 CFR 12.3 - Release under bond; liquidated damages.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 19 Customs Duties 1 2014-04-01 2014-04-01 false Release under bond; liquidated damages. 12.3 Section 12.3 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF THE TREASURY SPECIAL CLASSES OF MERCHANDISE Food, Drugs, and Cosmetics, Economic Poisons...
19 CFR 12.3 - Release under bond; liquidated damages.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 19 Customs Duties 1 2013-04-01 2013-04-01 false Release under bond; liquidated damages. 12.3 Section 12.3 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF THE TREASURY SPECIAL CLASSES OF MERCHANDISE Food, Drugs, and Cosmetics, Economic Poisons...
19 CFR 12.3 - Release under bond; liquidated damages.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 19 Customs Duties 1 2012-04-01 2012-04-01 false Release under bond; liquidated damages. 12.3 Section 12.3 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF THE TREASURY SPECIAL CLASSES OF MERCHANDISE Food, Drugs, and Cosmetics, Economic Poisons...
19 CFR 12.3 - Release under bond; liquidated damages.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 19 Customs Duties 1 2011-04-01 2011-04-01 false Release under bond; liquidated damages. 12.3 Section 12.3 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF THE TREASURY SPECIAL CLASSES OF MERCHANDISE Food, Drugs, and Cosmetics, Economic Poisons...
19 CFR 12.3 - Release under bond; liquidated damages.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 19 Customs Duties 1 2010-04-01 2010-04-01 false Release under bond; liquidated damages. 12.3 Section 12.3 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF THE TREASURY SPECIAL CLASSES OF MERCHANDISE Food, Drugs, and Cosmetics, Economic Poisons...
Perchlorate has been added to the U.S. Environmental Protection Agency,s Drinking Water Contaminant Candidate List (CCL). The present work describes the analysis of perchlorate in water by liquid-liquid extraction followed by flow injection electrospray mass spectrometry (ESI/MS...
33 CFR 151.49 - Category C and D Oil-like NLSs allowed for carriage.
Code of Federal Regulations, 2010 CFR
2010-07-01
... HOMELAND SECURITY (CONTINUED) POLLUTION VESSELS CARRYING OIL, NOXIOUS LIQUID SUBSTANCES, GARBAGE, MUNICIPAL OR COMMERCIAL WASTE, AND BALLAST WATER Implementation of MARPOL 73/78 and the Protocol on Environmental Protection to the Antarctic Treaty as it Pertains to Pollution from Ships Noxious Liquid Substance...
33 CFR 151.33 - Certificates needed to carry Category C Oil-like NLS.
Code of Federal Regulations, 2010 CFR
2010-07-01
... HOMELAND SECURITY (CONTINUED) POLLUTION VESSELS CARRYING OIL, NOXIOUS LIQUID SUBSTANCES, GARBAGE, MUNICIPAL OR COMMERCIAL WASTE, AND BALLAST WATER Implementation of MARPOL 73/78 and the Protocol on Environmental Protection to the Antarctic Treaty as it Pertains to Pollution from Ships Noxious Liquid Substance...
Code of Federal Regulations, 2012 CFR
2012-07-01
.... Electrostatic precipitator (ESP) means an air pollution control device in which solid or liquid particulates in... suface. High velocity air filter (HVAF) means an air pollution control filtration device for the removal... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF...
Code of Federal Regulations, 2013 CFR
2013-07-01
.... Electrostatic precipitator (ESP) means an air pollution control device in which solid or liquid particulates in... suface. High velocity air filter (HVAF) means an air pollution control filtration device for the removal... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF...
Code of Federal Regulations, 2014 CFR
2014-07-01
.... Electrostatic precipitator (ESP) means an air pollution control device in which solid or liquid particulates in... suface. High velocity air filter (HVAF) means an air pollution control filtration device for the removal... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF...
Code of Federal Regulations, 2011 CFR
2011-07-01
.... Electrostatic precipitator (ESP) means an air pollution control device in which solid or liquid particulates in... suface. High velocity air filter (HVAF) means an air pollution control filtration device for the removal... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF...
Code of Federal Regulations, 2010 CFR
2010-07-01
.... Electrostatic precipitator (ESP) means an air pollution control device in which solid or liquid particulates in... suface. High velocity air filter (HVAF) means an air pollution control filtration device for the removal... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF...
40 CFR 761.340 - Applicability.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES CONTROL ACT... Accordance With § 761.62, and Sampling PCB Remediation Waste Destined for Off-Site Disposal, in Accordance... generate new waste. (c) Non-liquid PCB remediation waste from processes that continuously generate new...
40 CFR 761.340 - Applicability.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES CONTROL ACT... Accordance With § 761.62, and Sampling PCB Remediation Waste Destined for Off-Site Disposal, in Accordance... generate new waste. (c) Non-liquid PCB remediation waste from processes that continuously generate new...
40 CFR 761.340 - Applicability.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES CONTROL ACT... Accordance With § 761.62, and Sampling PCB Remediation Waste Destined for Off-Site Disposal, in Accordance... generate new waste. (c) Non-liquid PCB remediation waste from processes that continuously generate new...
Kanellos, Theo; Sutton, David J; Salisbury, Claire F; Chalmers, William Stuart K
2008-08-01
Nobivac Tricat, a lyophilised trivalent modified live attenuated vaccine is routinely used to protect cats against three commonly diagnosed feline viral pathogens namely herpesvirus, calicivirus and panleukopenia virus. The recognition of feline leukaemia virus (FeLV) as an important viral pathogen has prompted the development of an efficacious liquid recombinant subunit FeLV vaccine (p45 envelope protein). Lyophilised Tricat vaccine was dissolved in the liquid FeLV vaccine and no detectable deleterious effect on the titre of any of the live virus components was observed after 2h incubation. In vivo studies where the vaccines were mixed in the same syringe prior to inoculation showed no alteration to the safety profile assessed by repeat and overdose studies. Serological comparisons of the modified live viral antibody titres showed no evidence of reduced responses following administration of the mixed products. Challenge studies using pathogenic herpesvirus and FeLV revealed no difference in the degree of clinical protection. This paper shows that neither safety nor efficacy is adversely affected as a result of mixing the two vaccines.
NASA Technical Reports Server (NTRS)
Williamson, Rebecca; Carbo, Jorge; Luna, Bernadette; Webbon, Bruce W.
1998-01-01
Wearing impermeable garments for hazardous materials clean up can often present a health and safety problem for the wearer. Even short duration clean up activities can produce heat stress injuries in hazardous materials workers. It was hypothesized that an internal cooling system might increase worker productivity and decrease likelihood of heat stress injuries in typical HazMat operations. Two HazMat protective ensembles were compared during treadmill exercise. The different ensembles were created using two different suits: a Trelleborg VPS suit representative of current HazMat suits and a prototype suit developed by NASA engineers. The two life support systems used were a current technology Interspiro Spirolite breathing apparatus and a liquid air breathing system that also provided convective cooling. Twelve local members of a HazMat team served as test subjects. They were fully instrumented to allow a complete physiological comparison of their thermal responses to the different ensembles. Results showed that cooling from the liquid air system significantly decreased thermal stress. The results of the subjective evaluations of new design features in the prototype suit were also highly favorable. Incorporation of these new design features could lead to significant operational advantages in the future.
NASA Astrophysics Data System (ADS)
Liu, Qiusheng; Yabe, Akira; Kajiyama, Shiro; Fukuda, Katsuya
The study on thermal energy transport system by synthesis and decomposition reactions of methanol was reviewed. To promote energy conservation and global environment protection, a two-step liquid-phase methanol synthesis process, which starts with carbonylation of methanol to methyl formate, then followed by the hydrogenolysis of the formate, was studied to recover wasted or unused discharged heat from industrial sources for the thermal energy demands of residential and commercial areas by chemical reactions. The research and development of the system were focused on the following three points. (1) Development of low-temperature decomposition and synthetic catalysts, (2) Development of liquid phase reactor (heat exchanger accompanying chemical reaction), (3) Simulation of the energy transport efficiency of entire system which contains heat recovery and supply sections. As the result of the development of catalyst, promising catalysts which agree with the development purposes for the methyl formate decomposition reaction and the synthetic reaction are being developed though some studies remain for the methanol decomposition and synthetic reactions. In the fundamental development of liquid phase reactor, the solubilities of CO and H2 gases in methanol and methyl formate were measured by the method of total pressure decrease due to absorption under pressures up to 1500kPa and temperatures up to 140°C. The diffusivity of CO gas in methanol was determined by measuring the diameter and solution time of single CO bubbles in methanol. The chemical reaction rate of methanol synthesis by hydrogenolysis of methyl formate was measured using a plate-type of Raney copper catalyst in a reactor with rectangular channel and in an autoclave reactor. The reaction characteristics were investigated by carrying out the experiments at various temperatures, flow rates and at various catalyst development conditions. We focused on the effect of Raney copper catalyst thickness on the liquid-phase chemical reaction by varying the development time of the catalyst. Investigation results of the catalyst such as surface area, pore radius, lattice size, and photographs of scanning electron microscope (SEM) were also given. In the simulation of energy transport efficiency of this system, by simulating the energy transfer system using two-step liquid phase methanol decomposition and synthetic reactions, and comparing with the technology so far, it can be expected that an innovative energy transfer system is possible to realize.
NASA Astrophysics Data System (ADS)
Scarlat, Raluca O.; Peterson, Per F.
2014-01-01
The fluoride salt cooled high temperature reactor (FHR) is a class of fission reactor designs that use liquid fluoride salt coolant, TRISO coated particle fuel, and graphite moderator. Heavy ion fusion (HIF) can likewise make use of liquid fluoride salts, to create thick or thin liquid layers to protect structures in the target chamber from ablation by target X-rays and damage from fusion neutron irradiation. This presentation summarizes ongoing work in support of design development and safety analysis of FHR systems. Development work for fluoride salt systems with application to both FHR and HIF includes thermal-hydraulic modeling and experimentation, salt chemistry control, tritium management, salt corrosion of metallic alloys, and development of major components (e.g., pumps, heat exchangers) and gas-Brayton cycle power conversion systems. In support of FHR development, a thermal-hydraulic experimental test bay for separate effects (SETs) and integral effect tests (IETs) was built at UC Berkeley, and a second IET facility is under design. The experiments investigate heat transfer and fluid dynamics and they make use of oils as simulant fluids at reduced scale, temperature, and power of the prototypical salt-cooled system. With direct application to HIF, vortex tube flow was investigated in scaled experiments with mineral oil. Liquid jets response to impulse loading was likewise studied using water as a simulant fluid. A set of four workshops engaging industry and national laboratory experts were completed in 2012, with the goal of developing a technology pathway to the design and licensing of a commercial FHR. The pathway will include experimental and modeling efforts at universities and national laboratories, requirements for a component test facility for reliability testing of fluoride salt equipment at prototypical conditions, requirements for an FHR test reactor, and development of a pre-conceptual design for a commercial reactor.
Evaluation of the surface free energy of plant surfaces: toward standardizing the procedure
Fernández, Victoria; Khayet, Mohamed
2015-01-01
Plant surfaces have been found to have a major chemical and physical heterogeneity and play a key protecting role against multiple stress factors. During the last decade, there is a raising interest in examining plant surface properties for the development of biomimetic materials. Contact angle measurement of different liquids is a common tool for characterizing synthetic materials, which is just beginning to be applied to plant surfaces. However, some studies performed with polymers and other materials showed that for the same surface, different surface free energy values may be obtained depending on the number and nature of the test liquids analyzed, materials' properties, and surface free energy calculation methods employed. For 3 rough and 3 rather smooth plant materials, we calculated their surface free energy using 2 or 3 test liquids and 3 different calculation methods. Regardless of the degree of surface roughness, the methods based on 2 test liquids often led to the under- or over-estimation of surface free energies as compared to the results derived from the 3-Liquids method. Given the major chemical and structural diversity of plant surfaces, it is concluded that 3 different liquids must be considered for characterizing materials of unknown physico-chemical properties, which may significantly differ in terms of polar and dispersive interactions. Since there are just few surface free energy data of plant surfaces with the aim of standardizing the calculation procedure and interpretation of the results among for instance, different species, organs, or phenological states, we suggest the use of 3 liquids and the mean surface tension values provided in this study. PMID:26217362
NASA Astrophysics Data System (ADS)
Tatsumoto, H.; Shirai, Y.; Shiotsu, M.; Hata, K.; Kobayashi, H.; Naruo, Y.; Inatani, Y.; Kato, T.; Futakawa, M.; Kinoshita, K.
2010-06-01
A thermal-hydraulics experimental system of liquid hydrogen was developed in order to investigate the forced flow heat transfer characteristics in the various cooling channels for wide ranges of subcoolings, flow velocities, and pressures up to supercritical. A main tank is connected to a sub tank through a hydrogen transfer line with a control valve. A channel heater is located at one end of the transfer line in the main tank. Forced flow through the channel is produced by adjusting the pressure difference between the tanks and the valve opening. The mass flow rate is measured from the weight change of the main tank. For the explosion protection, electrical equipments are covered with a nitrogen gas blanket layer and a remote control system was established. The first cryogenic performance tests confirmed that the experimental system had satisfied with the required performances. The forced convection heat transfer characteristics was successfully measured at the pressure of 0.7 MPa for various flow velocities.
Protein stability in pulmonary drug delivery via nebulization.
Hertel, Sebastian P; Winter, Gerhard; Friess, Wolfgang
2015-10-01
Protein inhalation is a delivery route which offers high potential for direct local lung application of proteins. Liquid formulations are usually available in early stages of biopharmaceutical development and nebulizers are the device of choice for atomization avoiding additional process steps like drying and enabling fast progression to clinical trials. While some proteins were proven to remain stable throughout aerosolization e.g. DNase, many biopharmaceuticals are more susceptible towards the stresses encountered during nebulization. The main reason for protein instability is unfolding and aggregation at the air-liquid interface, a problem which is of particular challenge in the case of ultrasound and jet nebulizers due to recirculation of much of the generated droplets. Surfactants are an important formulation component to protect the sensitive biomolecules. A second important challenge is warming of ultrasound and vibrating mesh devices, which can be overcome by overfilling, precooled solutions or cooling of the reservoir. Ultimately, formulation development has to go hand in hand with device evaluation. Copyright © 2014 Elsevier B.V. All rights reserved.
Simeoni, Silvia; Tursilli, Rosanna; Bianchi, Anna; Scalia, Santo
2005-06-15
A rapid high-performance liquid chromatographic method was developed for the simultaneous assay of eight of the most common sunscreen agents (octyl-methoxycinnamate, oxybenzone, butyl-methoxydibenzoylmethane, octyl-salicilate, methylbenzylidene camphor, octyl-dimethylamminobenzoate, phenylbenzimidazole sulphonic acid and octocrylene) in sun protection products. Evaluation of the influence of different stationary phases and eluents on the separation selectivity showed that optimal resolution was obtained on a cyanopropyl-silica column eluted with methanol-acetonitrile-tetrahydrofuran-aqueous acetic acid. A small adjustment of the proposed chromatographic system (reduction in the aqueous content of the mobile phase) permitted also the determination of the extremely hydrophobic UV filter, methylene bis-benzotriazolyl tetramethylbutylphenol along with three other sunscreen agents, octyl-methoxycinnamate, oxybenzone, butyl-methoxydibenzoylmethane. Recoveries of the UV filters from the spiked formulation were between 95.7 and 103.7% and the precision of the method was better than 6.1% relative standard deviation. The developed HPLC procedure is suitable for quality control and photostability analyses of commercial suncare products.
Aerogel Insulation Applications for Liquid Hydrogen Launch Vehicle Tanks
NASA Technical Reports Server (NTRS)
Fesmire, J. E.; Sass, J.
2007-01-01
Aerogel based insulation systems for ambient pressure environments were developed for liquid hydrogen (LH2) tank applications. Solutions to thermal insulation problems were demonstrated for the Space Shuttle External Tank (ET) through extensive testing at the Cryogenics Test Laboratory. Demonstration testing was performed using a 1/10th scale ET LH2 intertank unit and liquid helium as the coolant to provide the 20 K cold boundary temperature. Cryopumping tests in the range of 20K were performed using both constant mass and constant pressure methods. Long-duration tests (up to 10 hours) showed that the nitrogen mass taken up inside the intertank is reduced by a factor of nearly three for the aerogel insulated case as compared to the un-insulated (bare metal flight configuration) case. Test results including thermal stabilization, heat transfer effectiveness, and cryopumping confirm that the aerogel system eliminates free liquid nitrogen within the intertank. Physisorption (or adsorption) of liquid nitrogen within the fine pore structure of aerogel materials was also investigated. Results of a mass uptake method show that the sorption ratio (liquid nitrogen to aerogel beads) is about 62 percent by volume. A novel liquid nitrogen production method of testing the liquid nitrogen physical adsorption capacity of aerogel beads was also performed to more closely approximate the actual launch vehicle cooldown and thermal stabilization effects within the aerogel material. The extraordinary insulating effectiveness of the aerogel material shows that cryopumping is not an open-cell mass transport issue but is strictly driven by thermal communication between warm and cold surfaces. The new aerogel insulation technology is useful to solve heat transfer problem areas and to augment existing thermal protection systems on launch vehicles. Examples are given and potential benefits for producing launch systems that are more reliable, robust, reusable, and efficient are outlined.
7 CFR 1980.472 - Protective advances.
Code of Federal Regulations, 2010 CFR
2010-01-01
... Agriculture Regulations of the Department of Agriculture (Continued) RURAL HOUSING SERVICE, RURAL BUSINESS-COOPERATIVE SERVICE, RURAL UTILITIES SERVICE, AND FARM SERVICE AGENCY, DEPARTMENT OF AGRICULTURE (CONTINUED... liquidation is contemplated or in process. A precise rule of when a protective advance should be made is...
Design manual: Oxygen Thermal Test Article (OTTA)
NASA Technical Reports Server (NTRS)
Chronic, W. L.; Baese, C. L.; Conder, R. L.
1974-01-01
The characteristics of a cryogenic tank for storing liquid hydrogen, nitrogen, oxygen, methane, or helium for an extended period of time with minimum losses are discussed. A description of the tank and control module, assembly drawings and details of major subassemblies, specific requirements controlling development of the system, thermal concept considerations, thermal analysis methods, and a record of test results are provided. The oxygen thermal test article thermal protection system has proven that the insulation system for cryogenic vessels is effective.
Detector sustainability improvements at LCLS
NASA Astrophysics Data System (ADS)
Browne, Michael C.; Carini, Gabriella; DePonte, Daniel P.; Galtier, Eric C.; Hart, Philip A.; Koralek, J. D.; Mitra, Ankush; Nakahara, Kazutaka
2017-06-01
The Linac Coherent Light Source (LCLS) poses a number of daunting and often unusual challenges to maintaining X-ray detectors, such as proximity to liquid-sample injectors, complex setups with moving components, intense X-ray and optical laser light, and Electromagnetic Pulse (EMP). The Detector and Sample Environment departments at LCLS are developing an array of engineering, monitoring, and administrative controls solutions to better address these issues. These include injector improvements and monitoring methods, fast online damage recognition algorithms, EMP mapping and protection, actively cooled filters, and more.
2003-03-01
and landfills. Classified as dense non-aqueous phase liquids (DNAPLs) because of their high density and relatively low solubility in water ...Environmental Protection Agency (EPA) recommendations (U.S. EPA, 1992). Water was purged from the top of the piezometric head, to ensure full...that which is recognized by the EPA as “ low -flow purging,” fresh water within the well screen was hydraulically isolated from any stagnant water in the
Protective tubes for sodium heated water tubes
Essebaggers, Jan
1979-01-01
A heat exchanger in which water tubes are heated by liquid sodium which minimizes the results of accidental contact between the water and the sodium caused by failure of one or more of the water tubes. A cylindrical protective tube envelopes each water tube and the sodium flows axially in the annular spaces between the protective tubes and the water tubes.
Christopher J. Fettig; A. Steven Munson; Donald M. Grosman; Parshall B. Bush
2014-01-01
Protection of conifers from bark beetle colonization typically involves applications of liquid formulations of contact insecticides to the tree bole. An evaluation was made of the efficacy of bole injections of emamectin benzoate alone and combined with the fungicide propiconazole for protecting individual lodgepole pine, Pinus contorta Dougl. ex...
Occupational safety considerations with hydrazine
NASA Technical Reports Server (NTRS)
Clewell, Harvey J., III; Mcdougal, James N.; George, Marilyn E.; Andersen, Melvin E.
1992-01-01
Hydrazine is a reducing agent that is most commonly used as a propellant and as an oxygen scavenger in boilers. Hydrazine is extremely irritating and has been demonstrated to produce both acute and chronic toxicity. As a result, the established permissible inhalation exposure limits are very low, and respiration protection is required whenever vapors are present. Liquid hydrazine penetrates the skin and produces a chemical burn; therefore, some protective measures must also be taken to protect the skin from liquid contact. Often, however, a cumbersome, whole-body protective suit is worn to protect against skin contact with vapor as well. To what extent it is actually necessary to protect skin from vapor penetration had not previously been demonstrated. In an attempt to answer this question, we conducted a study with rats to compare the dermal penetration of hydrazine vapor with inhalation. Pharmacokinetic modeling was used to compare body burdens resulting from these different routes of exposure. The analysis concluded that the vapor concentration during a skin-only exposure would have to be at least 200 times higher than that during inhalation to achieve the same body burden. This type of estimation illustrates the use of predictive toxicology in occupational exposures.
Hydrophobic ionic liquids for quantitative bacterial cell lysis with subsequent DNA quantification.
Fuchs-Telka, Sabine; Fister, Susanne; Mester, Patrick-Julian; Wagner, Martin; Rossmanith, Peter
2017-02-01
DNA is one of the most frequently analyzed molecules in the life sciences. In this article we describe a simple and fast protocol for quantitative DNA isolation from bacteria based on hydrophobic ionic liquid supported cell lysis at elevated temperatures (120-150 °C) for subsequent PCR-based analysis. From a set of five hydrophobic ionic liquids, 1-butyl-1-methylpyrrolidinium bis(trifluoromethylsulfonyl)imide was identified as the most suitable for quantitative cell lysis and DNA extraction because of limited quantitative PCR inhibition by the aqueous eluate as well as no detectable DNA uptake. The newly developed method was able to efficiently lyse Gram-negative bacterial cells, whereas Gram-positive cells were protected by their thick cell wall. The performance of the final protocol resulted in quantitative DNA extraction efficiencies for Gram-negative bacteria similar to those obtained with a commercial kit, whereas the number of handling steps, and especially the time required, was dramatically reduced. Graphical Abstract After careful evaluation of five hydrophobic ionic liquids, 1-butyl-1-methylpyrrolidinium bis(trifluoromethylsulfonyl)imide ([BMPyr + ][Ntf 2 - ]) was identified as the most suitable ionic liquid for quantitative cell lysis and DNA extraction. When used for Gram-negative bacteria, the protocol presented is simple and very fast and achieves DNA extraction efficiencies similar to those obtained with a commercial kit. ddH 2 O double-distilled water, qPCR quantitative PCR.
FORMING PROTECTIVE FILMS ON METAL
Gurinsky, D.H.; Kammerer, O.F.; Sadofsky, J.; Weeks, J.R.
1958-12-16
Methods are described of inhibiting the corrosion of ferrous metal by contact with heavy liquid metals such as bismuth and gallium at temperatures above 500 icient laborato C generally by bringing nltrogen and either the metal zirconium, hafnium, or titanium into reactlve contact with the ferrous metal to form a thin adherent layer of the nitride of the metal and thereafter maintaining a fractional percentage of the metal absorbed in the heavy liquid metal in contact with the ferrous metal container. The general purpose for uslng such high boiling liquid metals in ferrous contalners would be as heat transfer agents in liquid-metal-fueled nuclear reactors.
Influence of Planetary Protection Guidelines on Waste Management Operations
NASA Technical Reports Server (NTRS)
Hogan, John A.; Fisher, John W.; Levri, Julie A.; Wignarajah, Kanapathipi; Race, Margaret S.; Stabekis, Perry D.; Rummel, John D.
2005-01-01
Newly outlined missions in the Space Exploration Initiative include extended human habitation on Mars. During these missions, large amounts of waste materials will be generated in solid, liquid and gaseous form. Returning these wastes to Earth will be extremely costly, and will therefore likely remain on Mars. Untreated, these wastes are a reservoir of live/dead organisms and molecules considered to be "biomarkers" i.e., indicators of life). If released to the planetary surface, these materials can potentially confound exobiology experiments and disrupt Martian ecology indefinitely (if existent). Waste management systems must therefore be specifically designed to control release of problematic materials both during the active phase of the mission, and for any specified post-mission duration. To effectively develop waste management requirements for Mars missions, planetary protection guidelines must first be established. While previous policies for Apollo lunar missions exist, it is anticipated that the increased probability of finding evidence of life on Mars, as well as the lengthy mission durations will initially lead to more conservative planetary protection measures. To facilitate the development of overall requirements for both waste management and planetary protection for future missions, a workshop was conducted to identify how these two areas interface, and to establish a preliminary set of planetary protection guidelines that address waste management operations. This paper provides background regarding past and current planetary protection and waste management issues, and their interactions. A summary of the recommended planetary protection guidelines, anticipated ramifications and research needs for waste management system design for both forward (Mars) and backward (Earth) contamination is also provided.
Li, Guoyun; Li, Lingyun; Xue, Changhu; Middleton, Dustin; Linhardt, Robert J.; Avci, Fikri Y.
2015-01-01
Pneumococcal type-3 polysaccharide (Pn3P) is considered a major target for the development of a human vaccine to protect against Streptococcus pneumonia infection. Thus, it is critical to develop methods for the preparation and analysis of Pn3P-derived oligosaccharides to better understand its immunological properties. In this paper, we profile oligosaccharides, generated by the free radical depolymerization of Pn3P, using liquid chromatography (LC)-tandem mass spectrometry (MS/MS). Hydrophilic liquid interaction chromatography (HILIC)-mass spectrometry (MS) revealed a series of oligosaccharides with an even- and odd-number of saccharide residues, ranging from monosaccharide, degree of polymerization (dp1) to large oligosaccharides up to dp 20, generated by free radical depolymerization. Isomers of oligosaccharides with an even number of sugar residues were easily separated on a HILIC column, and their sequences could be distinguished by comparing MS/MS of these oligosaccharides and their reduced alditols. Fluorescent labeling with 2-aminoacridone (AMAC) followed by reversed phase (RP)-LC-MS/MS was applied to analyze and sequence poorly separated product mixtures, as RP-LC affords higher resolution of AMAC-labeled oligosaccharides than does HILIC-based separation. The present methodology can be potentially applied to profiling other capsular polysaccharides. PMID:25913329
Li, Guoyun; Li, Lingyun; Xue, Changhu; Middleton, Dustin; Linhardt, Robert J; Avci, Fikri Y
2015-06-05
Pneumococcal type-3 polysaccharide (Pn3P) is considered a major target for the development of a human vaccine to protect against Streptococcus pneumoniae infection. Thus, it is critical to develop methods for the preparation and analysis of Pn3P-derived oligosaccharides to better understand its immunological properties. In this paper, we profile oligosaccharides, generated by the free radical depolymerization of Pn3P, using liquid chromatography (LC)-tandem mass spectrometry (MS/MS). Hydrophilic liquid interaction chromatography (HILIC)-mass spectrometry (MS) revealed a series of oligosaccharides with an even- and odd-number of saccharide residues, ranging from monosaccharide, degree of polymerization (dp1) to large oligosaccharides up to dp 20, generated by free radical depolymerization. Isomers of oligosaccharides with an even number of sugar residues were easily separated on a HILIC column, and their sequences could be distinguished by comparing MS/MS of these oligosaccharides and their reduced alditols. Fluorescent labeling with 2-aminoacridone (AMAC) followed by reversed phase (RP)-LC-MS/MS was applied to analyze and sequence poorly separated product mixtures, as RP-LC affords higher resolution of AMAC-labeled oligosaccharides than does HILIC-based separation. The present methodology can be potentially applied to profiling other capsular polysaccharides. Copyright © 2015 Elsevier B.V. All rights reserved.
10 CFR 851.27 - Reference sources.
Code of Federal Regulations, 2012 CFR
2012-01-01
... National Standards Institute (ANSI) Z88.2, “American National Standard for Respiratory Protection,” (1992...) B31.4—2002—Pipeline Transportation Systems for Liquid Hydrocarbons and Other Liquids; (v) B31.5—2001...—Gas Transmission and Distribution Piping Systems; (vii) B31.8S—2001—Managing System Integrity of Gas...
33 CFR 151.35 - Certificates needed to carry Category D NLS and Category D Oil-like NLS.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Protocol on Environmental Protection to the Antarctic Treaty as it Pertains to Pollution from Ships Noxious Liquid Substance Pollution § 151.35 Certificates needed to carry Category D NLS and Category D Oil-like... GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) POLLUTION VESSELS CARRYING OIL, NOXIOUS LIQUID...
33 CFR 151.33 - Certificates needed to carry Category C Oil-like NLS.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Environmental Protection to the Antarctic Treaty as it Pertains to Pollution from Ships Noxious Liquid Substance Pollution § 151.33 Certificates needed to carry Category C Oil-like NLS. (a) A U.S. oceangoing ship may not... HOMELAND SECURITY (CONTINUED) POLLUTION VESSELS CARRYING OIL, NOXIOUS LIQUID SUBSTANCES, GARBAGE, MUNICIPAL...
Ferrarini, Alberta; Ferroni, Fiammetta; Pieraccini, Silvia; Rosini, Carlo; Superchi, Stefano; Spada, Gian Piero
2011-10-01
The conversion into 6,7-dihydro-5H-dibenz[c,e]azepine (DAZ) N-protected amides is a viable route for the determination of the absolute configuration of chiral 2-substituted carboxylic acids. The biphenyl moiety of DAZ, besides being a probe of chirality for the electronic circular dichroism (ECD) spectroscopy, makes these systems suitable for configuration assignment by exploiting the chirality amplification which occurs in nematic liquid crystals. To assess the reliability of the liquid crystal method in detecting the absolute stereochemistry of chiral amides bound to a biphenyl group, we measured the helical twisting power of a series of DAZ-N-protected amides and compared these data with the results obtained from ECD measurements. We will show that the liquid crystal method, corroborated by HTP predictions, is trustworthy with our biphenyl derivatives, even when ECD spectra are ambiguous for the presence of aryl moieties displaying strong UV absorptions in the same range of the biphenyl chromophore. © 2011 Wiley-Liss, Inc.
Ionic liquids as a reaction medium for lipase-catalyzed methanolysis of sunflower oil.
Sunitha, S; Kanjilal, S; Reddy, P S; Prasad, R B N
2007-12-01
Ionic liquids, 1-butyl-3-methyl imidazolium hexafluorophosphate ([BMIm][PF(6)]) and 1-ethyl-3-methyl imidazolium hexafluorophosphate ([EMIm][PF(6)]), were used for the methanolysis of sunflower oil using Candida antarctica lipase (Novozyme 435) and gave yields of fatty acid methyl esters at 98-99% within 10 h. The optimum conditions of methanolysis in hydrophobic ionic liquids are 2% (w/w) lipase, 1:1 (w/w) oil/ionic liquid and 1:8 (mol/mol) oil/methanol at 58-60 degrees C. Methanolysis using hydrophilic ionic liquids, 3-methyl imidazolium tetrafluoroborate ([HMIm][BF(4)]) and 1-butyl-3-methyl imidazolium tetrafluoroborate ([BMIm][BF(4)]), gave very poor yields. A hydrophobic ionic liquid thus protects the lipase from methanol. Recovered ionic liquids and lipase were used for four successive reaction cycles without any significant loss of activity.
33 CFR 154.812 - Facility requirements for vessel liquid overfill protection.
Code of Federal Regulations, 2010 CFR
2010-07-01
... accordance with 46 CFR 39.20-9(a) as its only means of overfill protection must provide a 120 volt, 20 amp...) Has a female connecting plug for the tank barge level sensor system with a 5 wire, 16 amp connector...
40 CFR 152.6 - Substances excluded from regulation by FIFRA.
Code of Federal Regulations, 2012 CFR
2012-07-01
... FIFRA. 152.6 Section 152.6 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... from FIFRA regulation if they meet the specified conditions or criteria. (a) Liquid chemical sterilants... urease production through action affecting soil bacteria and is distributed and sold solely for those...
40 CFR 152.6 - Substances excluded from regulation by FIFRA.
Code of Federal Regulations, 2014 CFR
2014-07-01
... FIFRA. 152.6 Section 152.6 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... from FIFRA regulation if they meet the specified conditions or criteria. (a) Liquid chemical sterilants... urease production through action affecting soil bacteria and is distributed and sold solely for those...
40 CFR 152.6 - Substances excluded from regulation by FIFRA.
Code of Federal Regulations, 2013 CFR
2013-07-01
... FIFRA. 152.6 Section 152.6 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... from FIFRA regulation if they meet the specified conditions or criteria. (a) Liquid chemical sterilants... urease production through action affecting soil bacteria and is distributed and sold solely for those...
40 CFR 761.348 - Contemporaneous sampling.
Code of Federal Regulations, 2014 CFR
2014-07-01
... PROHIBITIONS Sampling Non-Liquid, Non-Metal PCB Bulk Product Waste for Purposes of Characterization for PCB Disposal in Accordance With § 761.62, and Sampling PCB Remediation Waste Destined for Off-Site Disposal... Section 761.348 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES...
40 CFR 761.348 - Contemporaneous sampling.
Code of Federal Regulations, 2012 CFR
2012-07-01
... PROHIBITIONS Sampling Non-Liquid, Non-Metal PCB Bulk Product Waste for Purposes of Characterization for PCB Disposal in Accordance With § 761.62, and Sampling PCB Remediation Waste Destined for Off-Site Disposal... Section 761.348 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES...
40 CFR 761.348 - Contemporaneous sampling.
Code of Federal Regulations, 2013 CFR
2013-07-01
... PROHIBITIONS Sampling Non-Liquid, Non-Metal PCB Bulk Product Waste for Purposes of Characterization for PCB Disposal in Accordance With § 761.62, and Sampling PCB Remediation Waste Destined for Off-Site Disposal... Section 761.348 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES...
Guo, Wei; Zhou, Yan; Sang, Xiahan; ...
2017-06-20
The development of advanced lubricant additives has been a critical component in paving the way for increasing energy efficiency and durability for numerous industry applications. However, the formation mechanisms of additive-induced protective tribofilms are not yet fully understood because of the complex chemomechanical interactions at the contact interface and the limited spatial resolution of many characterizing techniques currently used. In this paper, the tribofilms on a gray cast iron surface formed by three antiwear additives are systematically studied; a phosphonium-phosphate ionic liquid (IL), a zinc dialkyldithiophosphate (ZDDP), and an IL+ZDDP combination. All three additives provide excellent wear protection, with themore » IL+ZDDP combination exhibiting a synergetic effect, resulting in further reduced friction and wear. Atom probe tomography (APT) and scanning transmission electron microscopy (STEM) imaging and electron energy loss spectroscopy (EELS) were used to interrogate the subnm chemistry and bonding states for each of the tribofilms of interest. The IL tribofilm appeared amorphous and was Fe, P, and O rich. Wear debris particles having an Fe-rich core and an oxide shell were present in this tribofilm and a transitional oxide (Fe 2O 3)-containing layer was identified at the interface between the tribofilm and the cast iron substrate. The ZDDP+IL tribofilm shared some of the characteristics found in the IL and ZDDP tribofilms. Finally, tribofilm formation mechanisms are proposed on the basis of the observations made at the atomic level.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Guo, Wei; Zhou, Yan; Sang, Xiahan
The development of advanced lubricant additives has been a critical component in paving the way for increasing energy efficiency and durability for numerous industry applications. However, the formation mechanisms of additive-induced protective tribofilms are not yet fully understood because of the complex chemomechanical interactions at the contact interface and the limited spatial resolution of many characterizing techniques currently used. In this paper, the tribofilms on a gray cast iron surface formed by three antiwear additives are systematically studied; a phosphonium-phosphate ionic liquid (IL), a zinc dialkyldithiophosphate (ZDDP), and an IL+ZDDP combination. All three additives provide excellent wear protection, with themore » IL+ZDDP combination exhibiting a synergetic effect, resulting in further reduced friction and wear. Atom probe tomography (APT) and scanning transmission electron microscopy (STEM) imaging and electron energy loss spectroscopy (EELS) were used to interrogate the subnm chemistry and bonding states for each of the tribofilms of interest. The IL tribofilm appeared amorphous and was Fe, P, and O rich. Wear debris particles having an Fe-rich core and an oxide shell were present in this tribofilm and a transitional oxide (Fe 2O 3)-containing layer was identified at the interface between the tribofilm and the cast iron substrate. The ZDDP+IL tribofilm shared some of the characteristics found in the IL and ZDDP tribofilms. Finally, tribofilm formation mechanisms are proposed on the basis of the observations made at the atomic level.« less
Wu, Jingming; Lee, Hian Kee
2006-10-15
Injection port derivatization following ion-pair hollow fiber-protected liquid-phase microextraction (LPME) for the trace determination of acidic herbicides (2,4-dichlorobenzoic acid, 2,4-dichlorophenoxyacetic acid, 2-(2,4-dichlorophenoxy)propionic acid, 3,5-dichlorobenzoic acid, 2-(2,4,5-trichlorophenoxy)propionic acid) in aqueous samples by gas chromatography/mass spectrometry (GC/MS) was developed. Prior to GC injection port derivatization, acidic herbicides were converted into their ion-pair complexes with tetrabutylammonium chloride in aqueous samples and then extracted by 1-octanol impregnated in the hollow fiber. Upon injection, ion pairs of acidic herbicides were quantitatively derivatized to their butyl esters in the GC injection port. Thus, several parameters related to the derivatization process (i.e., injection temperature, purge-off time) were evaluated, and main parameters affecting the hollow fiber-protected LPME procedure such as extraction organic solvent, ion-pair reagent type, pH of aqueous medium, concentration of ion-pair reagent, sodium chloride concentration added to the aqueous medium, stirring speed, and extraction time profile, optimized. At the selected extraction and derivatization conditions, no matrix effects were observed. This method proved good repeatability (RSDs <12.3%, n = 6) and good linearity (r2 > or = 0.9939) for spiked deionized water samples for five analytes. The limits of detection were in the range of 0.51-13.7 ng x L(-1) (S/N =3) under GC/MS selected ion monitoring mode. The results demonstrated that injection port derivatization following ion-pair hollow fiber-protected LPME was a simple, rapid, and accurate method for the determination of trace acidic herbicides from aqueous samples. In addition, this method proved to be environmentally friendly since it completely avoided open derivatization with potentially hazardous reagents.
Consortium for Algal Biofuel Commercialization (CAB-COMM) Final Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mayfield, Stephen P.
The Consortium for Algal Biofuel Commercialization (CAB-Comm) was established in 2010 to conduct research to enable commercial viability of alternative liquid fuels produced from algal biomass. The main objective of CAB-Comm was to dramatically improve the viability of algae as a source of liquid fuels to meet US energy needs, by addressing several significant barriers to economic viability. To achieve this goal, CAB-Comm took a diverse set of approaches on three key aspects of the algal biofuels value chain: crop protection; nutrient utilization and recycling; and the development of genetic tools. These projects have been undertaken as collaboration between sixmore » academic institutions and two industrial partners: University of California, San Diego; Scripps Institution of Oceanography; University of Nebraska, Lincoln; Rutgers University; University of California, Davis; Johns Hopkins University; Sapphire Energy; and Life Technologies.« less
Biodecontamination of concrete
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rogers, R.D.
1995-12-31
This paper describes the development and results of a demonstration for a continuous bioprocess for mixed waste treatment. A key element of the process is a unique microbial strain, which tolerates high levels of aromatic solvents and surfactants. This microorganism is the biocatalysis of the continuous flow system designed for processing stored liquid scintillation wastes. During the past year, a process demonstration has been conducted on commercial formulation of liquid scintillation cocktails (LSQ). Based on data obtained from this demonstration, the Ohio Environmental Protection Agency granted the Mound Applied Technologies Laboratory a treatability permit allowing the limited processing of actualmore » mixed waste. Since August 1994, the system has been successfully processing stored {open_quotes}hot{close_quotes} LSC waste. This paper discusses the bioprocess, rates of processing, effluent, and implications of bioprocessing for mixed waste management.« less
Permeation Resistance of Chlorinated Polyethylene Against Hydrazine Fuels
NASA Technical Reports Server (NTRS)
Waller, J. M.; Williams, J. H.
1999-01-01
The permeation resistance of chlorinated polyethylene (CPE) used in chemical protective clothing against the aerospace fuels hydrazine, monomethylhydrazine (MMH), and uns-dimethylhydrazine (UDMH) was determined by measuring breakthrough times and time-averaged vapor transmission rates using an ASTM F 739 permeation cell. Two exposure scenarios were simulated: a 2 hour (h) fuel vapor exposure, and a liquid fuel "splash" followed by a 2 h vapor exposure. To simulate internal suit pressure during operation, a positive differential pressure of 0.3 in. water (75 Pa) on the collection side of the permeation apparatus was used. Breakthrough was observed after exposure to liquid MMH, and to vapor and liquid UDMH. No breakthrough was observed after exposure to vapor and liquid hydrazine, or vapor MMH. A model was then used to calculate propellant concentrations inside a totally encapsulating chemical protective suit based on the ASTM permeation data obtained in the present study. Concentrations were calculated under conditions of fixed vapor transmission rate, variable breathing air flow rate, and variable splash exposure area. Calculations showed that the maximum allowable permeation rates of hydrazine fuels through CPE were of the order of 0.05 to 0.08 ng sq cm/min for encapsulating suits with low breathing air flow rates (of the order of 5 scfm or 140 L/min). Above these permeation rates, the 10 parts per billion (ppb) threshold limit value time - weighted average could be exceeded for chemical protective suits having a CPE torso. To evaluate suit performance at ppb level concentrations, use of a sensitive analytical method such as cation exchange high performance liquid chromatography with amperometric detection was found to be essential.
40 CFR 761.346 - Three levels of sampling.
Code of Federal Regulations, 2012 CFR
2012-07-01
... PROHIBITIONS Sampling Non-Liquid, Non-Metal PCB Bulk Product Waste for Purposes of Characterization for PCB Disposal in Accordance With § 761.62, and Sampling PCB Remediation Waste Destined for Off-Site Disposal... Section 761.346 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES...
40 CFR 761.356 - Conducting a leach test.
Code of Federal Regulations, 2013 CFR
2013-07-01
... PROHIBITIONS Sampling Non-Liquid, Non-Metal PCB Bulk Product Waste for Purposes of Characterization for PCB Disposal in Accordance With § 761.62, and Sampling PCB Remediation Waste Destined for Off-Site Disposal... Section 761.356 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES...
40 CFR 761.346 - Three levels of sampling.
Code of Federal Regulations, 2013 CFR
2013-07-01
... PROHIBITIONS Sampling Non-Liquid, Non-Metal PCB Bulk Product Waste for Purposes of Characterization for PCB Disposal in Accordance With § 761.62, and Sampling PCB Remediation Waste Destined for Off-Site Disposal... Section 761.346 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES...
40 CFR 761.350 - Subsampling from composite samples.
Code of Federal Regulations, 2014 CFR
2014-07-01
..., AND USE PROHIBITIONS Sampling Non-Liquid, Non-Metal PCB Bulk Product Waste for Purposes of Characterization for PCB Disposal in Accordance With § 761.62, and Sampling PCB Remediation Waste Destined for Off.... 761.350 Section 761.350 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC...
40 CFR 761.350 - Subsampling from composite samples.
Code of Federal Regulations, 2012 CFR
2012-07-01
..., AND USE PROHIBITIONS Sampling Non-Liquid, Non-Metal PCB Bulk Product Waste for Purposes of Characterization for PCB Disposal in Accordance With § 761.62, and Sampling PCB Remediation Waste Destined for Off.... 761.350 Section 761.350 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC...
40 CFR 761.356 - Conducting a leach test.
Code of Federal Regulations, 2014 CFR
2014-07-01
... PROHIBITIONS Sampling Non-Liquid, Non-Metal PCB Bulk Product Waste for Purposes of Characterization for PCB Disposal in Accordance With § 761.62, and Sampling PCB Remediation Waste Destined for Off-Site Disposal... Section 761.356 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES...
40 CFR 761.346 - Three levels of sampling.
Code of Federal Regulations, 2014 CFR
2014-07-01
... PROHIBITIONS Sampling Non-Liquid, Non-Metal PCB Bulk Product Waste for Purposes of Characterization for PCB Disposal in Accordance With § 761.62, and Sampling PCB Remediation Waste Destined for Off-Site Disposal... Section 761.346 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES...
40 CFR 761.356 - Conducting a leach test.
Code of Federal Regulations, 2012 CFR
2012-07-01
... PROHIBITIONS Sampling Non-Liquid, Non-Metal PCB Bulk Product Waste for Purposes of Characterization for PCB Disposal in Accordance With § 761.62, and Sampling PCB Remediation Waste Destined for Off-Site Disposal... Section 761.356 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES...
40 CFR 761.350 - Subsampling from composite samples.
Code of Federal Regulations, 2013 CFR
2013-07-01
..., AND USE PROHIBITIONS Sampling Non-Liquid, Non-Metal PCB Bulk Product Waste for Purposes of Characterization for PCB Disposal in Accordance With § 761.62, and Sampling PCB Remediation Waste Destined for Off.... 761.350 Section 761.350 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC...
40 CFR 761.356 - Conducting a leach test.
Code of Federal Regulations, 2011 CFR
2011-07-01
... PROHIBITIONS Sampling Non-Liquid, Non-Metal PCB Bulk Product Waste for Purposes of Characterization for PCB Disposal in Accordance With § 761.62, and Sampling PCB Remediation Waste Destined for Off-Site Disposal... Section 761.356 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES...
Zhang, Xiaotao; Hou, Hongwei; Chen, Huan; Liu, Yong; Wang, An; Hu, Qingyuan
2015-09-17
A stable isotope dilution liquid chromatography with tandem mass spectrometry method for the analysis of 16 polycyclic aromatic hydrocarbons in cigarette smoke condensate was developed and validated. Compared with previously reported methods, this method has lower limits of detection (0.04-1.35 ng/cig). Additionally, the proposed method saves time, reduces the number of separation steps, and reduces the quantity of solvent needed. The new method was applied to evaluate polycyclic aromatic hydrocarbon content in 213 commercially available cigarettes in China, under the International Standardization Organization smoking regime and the Health Canadian intense smoking regime. The results showed that the total polycyclic aromatic hydrocarbon content was more than two times higher in samples from the Health Canadian intense smoking regime than in samples from the International Standardization Organization smoking regime (1189.23 vs. 2859.50 ng/cig, p<0.05). Meanwhile, the concentration of individual polycyclic aromatic hydrocarbons (and total polycyclic aromatic hydrocarbons) increased with labeled tar content in both of the tested smoking regimes. There was a positive correlation between total polycyclic aromatic hydrocarbons under the International Standardization Organization smoking regime with that under the Health Canadian intense smoking regime. The proposed liquid chromatography with tandem mass spectrometry method is satisfactory for the rapid, sensitive, and accurately quantitative evaluation of polycyclic aromatic hydrocarbon content in cigarette smoke condensate, and it can be applied to assess potential health risks from smoking. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
NASA Technical Reports Server (NTRS)
Pickett, Lorri A. (Editor)
1995-01-01
Topics covered include: Risk assessment of hazardous materials, Automated systems for pollution prevention and hazardous materials elimination, Study design for the toxicity evaluation of ammonium perchlorate, Plasma sprayed bondable stainless surface coatings, Development of CFC-free cleaning processes, New fluorinated solvent alternatives to ozone depleting solvents, Cleaning with highly fluorinated liquids, Biotreatment of propyleneglycol nitrate by anoxic denitrification, Treatment of hazardous waste with white rot fungus, Hydrothermal oxidation as an environmentally benign treatment technology, Treatment of solid propellant manufacturing wastes by base hydrolysis, Design considerations for cleaning using supercritical fluid technology, and Centrifugal shear carbon dioxide cleaning.