Summary of studies on the blue-green autofluorescence and light transmission of the ocular lens
NASA Astrophysics Data System (ADS)
Van Best, Jaap A.; Kuppens, Esmeralda V.
1996-07-01
This paper reviews previous work done to demonstrate the clinical relevance of the measurement of blue-green autofluorescence and light transmission of the ocular lens. These can be determined quantitatively with fluorophotometry in a few seconds. Autofluorescence and transmission values are determined in healthy volunteers, in patients with insulin-dependent diabetes mellitus, and in patients with untreated glaucoma or untreated ocular hypertension. The lens autofluorescence of healthy volunteers increased linearly and transmission decreased exponentially with age. Each year of diabetes induced an increase of autofluorescence equal to one extra year of age. Untreated glaucoma or ocular hypertension had no significant effect on lens autofluorescence and transmission. Increased autofluorescence and decreased transmission values in comparison with values of a healthy population are proved to be indicative for an increased risk of developing cataract and the clinical usefulness of these measures is demonstrated. Diabetes is a risk factor for developing cataracts while untreated glaucoma or ocular hypertension is not.
Influence of refractive correction on ocular dominance
NASA Astrophysics Data System (ADS)
Nakayama, Nanami; Kawamorita, Takushi; Uozato, Hiroshi
2010-07-01
We investigated the effects of refractive correction and refractive defocus on the assessment of sensory ocular dominance. In 25 healthy subjects (4 males and 21 females) aged between 20 and 31 years, a quantitative measurement of sensory ocular dominance was performed with refractive correction and the addition of a positive lens on the dominant eye. Sensory ocular dominance was measured with a chart using binocular rivalry targets. The reversal point changed after the addition of a +1.00 D lens on the dominant eye in all subjects. However, sighting ocular dominance and stereopsis did not change after the addition of a positive lens on the dominant eye ( P > 0:05, Wilcoxon test). These results suggest that refractive correction affects sensory ocular dominance, indicating the possible development of a new type of occlusion for amblyopia in the future.
Wearable smart sensor systems integrated on soft contact lenses for wireless ocular diagnostics
Kim, Joohee; Kim, Minji; Lee, Mi-Sun; Kim, Kukjoo; Ji, Sangyoon; Kim, Yun-Tae; Park, Jihun; Na, Kyungmin; Bae, Kwi-Hyun; Kyun Kim, Hong; Bien, Franklin; Young Lee, Chang; Park, Jang-Ung
2017-01-01
Wearable contact lenses which can monitor physiological parameters have attracted substantial interests due to the capability of direct detection of biomarkers contained in body fluids. However, previously reported contact lens sensors can only monitor a single analyte at a time. Furthermore, such ocular contact lenses generally obstruct the field of vision of the subject. Here, we developed a multifunctional contact lens sensor that alleviates some of these limitations since it was developed on an actual ocular contact lens. It was also designed to monitor glucose within tears, as well as intraocular pressure using the resistance and capacitance of the electronic device. Furthermore, in-vivo and in-vitro tests using a live rabbit and bovine eyeball demonstrated its reliable operation. Our developed contact lens sensor can measure the glucose level in tear fluid and intraocular pressure simultaneously but yet independently based on different electrical responses. PMID:28447604
Wearable smart sensor systems integrated on soft contact lenses for wireless ocular diagnostics.
Kim, Joohee; Kim, Minji; Lee, Mi-Sun; Kim, Kukjoo; Ji, Sangyoon; Kim, Yun-Tae; Park, Jihun; Na, Kyungmin; Bae, Kwi-Hyun; Kyun Kim, Hong; Bien, Franklin; Young Lee, Chang; Park, Jang-Ung
2017-04-27
Wearable contact lenses which can monitor physiological parameters have attracted substantial interests due to the capability of direct detection of biomarkers contained in body fluids. However, previously reported contact lens sensors can only monitor a single analyte at a time. Furthermore, such ocular contact lenses generally obstruct the field of vision of the subject. Here, we developed a multifunctional contact lens sensor that alleviates some of these limitations since it was developed on an actual ocular contact lens. It was also designed to monitor glucose within tears, as well as intraocular pressure using the resistance and capacitance of the electronic device. Furthermore, in-vivo and in-vitro tests using a live rabbit and bovine eyeball demonstrated its reliable operation. Our developed contact lens sensor can measure the glucose level in tear fluid and intraocular pressure simultaneously but yet independently based on different electrical responses.
Wearable smart sensor systems integrated on soft contact lenses for wireless ocular diagnostics
NASA Astrophysics Data System (ADS)
Kim, Joohee; Kim, Minji; Lee, Mi-Sun; Kim, Kukjoo; Ji, Sangyoon; Kim, Yun-Tae; Park, Jihun; Na, Kyungmin; Bae, Kwi-Hyun; Kyun Kim, Hong; Bien, Franklin; Young Lee, Chang; Park, Jang-Ung
2017-04-01
Wearable contact lenses which can monitor physiological parameters have attracted substantial interests due to the capability of direct detection of biomarkers contained in body fluids. However, previously reported contact lens sensors can only monitor a single analyte at a time. Furthermore, such ocular contact lenses generally obstruct the field of vision of the subject. Here, we developed a multifunctional contact lens sensor that alleviates some of these limitations since it was developed on an actual ocular contact lens. It was also designed to monitor glucose within tears, as well as intraocular pressure using the resistance and capacitance of the electronic device. Furthermore, in-vivo and in-vitro tests using a live rabbit and bovine eyeball demonstrated its reliable operation. Our developed contact lens sensor can measure the glucose level in tear fluid and intraocular pressure simultaneously but yet independently based on different electrical responses.
The Endocytic Recycling Regulatory Protein EHD1 Is Required for Ocular Lens Development
Arya, Priyanka; Rainey, Mark A.; Bhattacharyya, Sohinee; Mohapatra, Bhopal; George, Manju; Kuracha, Murali R; Storck, Matthew D.; Band, Vimla; Govindarajan, Venkatesh; Band, Hamid
2015-01-01
The C-terminal Eps15 homology domain-containing (EHD) proteins play a key role in endocytic recycling, a fundamental cellular process that ensures the return of endocytosed membrane components and receptors back to the cell surface. To define the in vivo biological functions of EHD1, we have generated Ehd1 knockout mice and previously reported a requirement of EHD1 for spermatogenesis. Here, we show that approximately 56% of the Ehd1-null mice displayed gross ocular abnormalities, including anophthalmia, aphakia, microphthalmia and congenital cataracts. Histological characterization of ocular abnormalities showed pleiotropic defects that include a smaller or absent lens, persistence of lens stalk and hyaloid vasculature, and deformed optic cups. To test whether these profound ocular defects resulted from the loss of EHD1 in the lens or in non-lenticular tissues, we deleted the Ehd1 gene selectively in the presumptive lens ectoderm using Le-Cre. Conditional Ehd1 deletion in the lens resulted in developmental defects that included thin epithelial layers, small lenses and absence of corneal endothelium. Ehd1 deletion in the lens also resulted in reduced lens epithelial proliferation, survival and expression of junctional proteins E-cadherin and ZO-1. Finally, Le-Cre-mediated deletion of Ehd1 in the lens led to defects in corneal endothelial differentiation. Taken together, these data reveal a unique role for EHD1 in early lens development and suggest a previously unknown link between the endocytic recycling pathway and regulation of key developmental processes including proliferation, differentiation and morphogenesis. PMID:26455409
Cornea and ocular lens visualized with three-dimensional confocal microscopy
NASA Astrophysics Data System (ADS)
Masters, Barry R.
1992-08-01
This paper demonstrates the advantages of three-dimensional reconstruction of the cornea and the ocular crystalline lens by confocal microscopy and volume rendering computer techniques. The advantages of noninvasive observation of ocular structures in living, unstained, unfixed tissue include the following: the tissue is in a natural living state without the artifacts of fixation, mechanical sectioning, and staining; the three-dimensional structure can be observed from any view point and quantitatively analyzed; the dynamics of morphological changes can be studied; and the use of confocal microscopic observation results in a reduction of the number of animals required for ocular morphometric studies. The main advantage is that the dynamic morphology of ocular structures can be investigated in living ocular tissue. A laser scanning confocal microscope was used in the reflected light mode to obtain the two- dimensional images from the cornea and the ocular lens of a freshly enucleated rabbit eye. The light source was an argon ion laser with 488 nm wavelength. The microscope objective was a Leitz 25X, NA 0.6 water immersion lens. The 400 micron thick cornea was optically sectioned into 133, three micron sections. The semi-transparent cornea and the in-situ ocular lens was visualized as high resolution, high contrast two-dimensional images. The under sampling resulted in a three-dimensional visualization rendering in which the corneal thickness (z-axis) is compressed. The structures observed in the cornea include: superficial epithelial cells and their nuclei, basal epithelial cells and their `beaded' cell borders, basal lamina, nerve plexus, nerve fibers, free nerve endings in the basal epithelial cells, nuclei of stromal keratocytes, and endothelial cells. The structures observed in the in-situ ocular lens include: lens capsule, lens epithelial cells, and individual lens fibers.
Design considerations of a real-time clinical confocal microscope
NASA Astrophysics Data System (ADS)
Masters, Barry R.
1991-06-01
A real-time clinical confocal light microscope provides the ophthalmologist with a new tool for the observation of the cornea and the ocular lens. In addition, the ciliary body, the iris, and the sclera can be observed. The real-time light microscopic images have high contrast and resolution. The transverse resolution is about one half micron and the range resolution is one micron. The following observations were made with visible light: corneal epithelial cells, wing cells, basal cells, Bowman's membrane, nerve fibers, basal lamina, fibroblast nuclei, Descemet's membrane, endothelial cells. Observation of the in situ ocular lens showed lens capsule, lens epithelium, lens fibrils, the interior of lens fibrils. The applications of the confocal microscope include: eye banking, laser refractive surgery, observation of wound healing, observation of the iris, the sciera, the ciliary body, the ocular lens, and the intraocular lens. Digital image processing can produce three-dimensional reconstructions of the cornea and the ocular lens.
Three-dimensional confocal microscopy of the living cornea and ocular lens
NASA Astrophysics Data System (ADS)
Masters, Barry R.
1991-07-01
The three-dimensional reconstruction of the optic zone of the cornea and the ocular crystalline lens has been accomplished using confocal microscopy and volume rendering computer techniques. A laser scanning confocal microscope was used in the reflected light mode to obtain the two-dimensional images from the cornea and the ocular lens of a freshly enucleated rabbit eye. The light source was an argon ion laser with a 488 nm wavelength. The microscope objective was a Leitz X25, NA 0.6 water immersion lens. The 400 micron thick cornea was optically sectioned into 133 three micron sections. The semi-transparent cornea and the in-situ ocular lens was visualized as high resolution, high contrast two-dimensional images. The structures observed in the cornea include: superficial epithelial cells and their nuclei, basal epithelial cells and their 'beaded' cell borders, basal lamina, nerve plexus, nerve fibers, nuclei of stromal keratocytes, and endothelial cells. The structures observed in the in- situ ocular lens include: lens capsule, lens epithelial cells, and individual lens fibers. The three-dimensional data sets of the cornea and the ocular lens were reconstructed in the computer using volume rendering techniques. Stereo pairs were also created of the two- dimensional ocular images for visualization. The stack of two-dimensional images was reconstructed into a three-dimensional object using volume rendering techniques. This demonstration of the three-dimensional visualization of the intact, enucleated eye provides an important step toward quantitative three-dimensional morphometry of the eye. The important aspects of three-dimensional reconstruction are discussed.
Changes in the Eye Microbiota Associated with Contact Lens Wearing
Price, Kenneth; Albert, Luong; Dodick, Jack; Park, Lisa
2016-01-01
ABSTRACT Wearing contact lenses has been identified as a risk factor for the development of eye conditions such as giant papillary conjunctivitis and keratitis. We hypothesized that wearing contact lenses is associated with changes in the ocular microbiota. We compared the bacterial communities of the conjunctiva and skin under the eye from 58 subjects and analyzed samples from 20 subjects (9 lens wearers and 11 non-lens wearers) taken at 3 time points using a 16S rRNA gene-based sequencing technique (V4 region; Illumina MiSeq). We found that using anesthetic eye drops before sampling decreases the detected ocular microbiota diversity. Compared to those from non-lens wearers, dry conjunctival swabs from lens wearers had more variable and skin-like bacterial community structures (UniFrac; P value = <0.001), with higher abundances of Methylobacterium, Lactobacillus, Acinetobacter, and Pseudomonas and lower abundances of Haemophilus, Streptococcus, Staphylococcus, and Corynebacterium (linear discriminant analysis [LDA] score = >3.0). The results indicate that wearing contact lenses alters the microbial structure of the ocular conjunctiva, making it more similar to that of the skin microbiota. Further research is needed to determine whether the microbiome structure provides less protection from ocular infections. PMID:27006462
Adams, Mark; Wang, Eric; Zhuang, Xiaohong; Klauda, Jeffery B
2017-11-21
The lipid composition of bovine and human ocular lens membranes has been probed, and a variety of lipids have been found including phosphatidylcholine (PC), phosphatidylethanolamine (PE), sphingomyelin (SM), and cholesterol (CHOL) with cholesterol being present in particularly high concentrations. In this study, we use the all-atom CHARMM36 force field to simulate binary, ternary, and quaternary mixtures as models of the ocular lens. High concentration of cholesterol, in combination with different and varying diversity of phospholipids (PL) and sphingolipids (SL), affect the structure of the ocular lens lipid bilayer. The following analyses were done for each simulation: surface area per lipid, component surface area per lipid, deuterium order parameters (S CD ), electron density profiles (EDP), membrane thickness, hydrogen bonding, radial distribution functions, clustering, and sterol tilt angle distribution. The S CD show significant bilayer alignment and packing in cholesterol-rich bilayers. The EDP show the transition from liquid crystalline to liquid ordered with the addition of cholesterol. Hydrogen bonds in our systems show the tendency for intramolecular interactions between cholesterol and fully saturated lipid tails for less complex bilayers. But with an increased number of components in the bilayer, the acyl chain of the lipids becomes a less important characteristic, and the headgroup of the lipid becomes more significant. Overall, cholesterol is the driving force of membrane structure of the ocular lens membrane where interactions between cholesterol, PL, and SL determine structure and function of the biomembrane. The goal of this work is to develop a baseline for further study of more physiologically realistic ocular lens lipid membranes. This article is part of a Special Issue entitled: Emergence of Complex Behavior in Biomembranes edited by Marjorie Longo. Copyright © 2017 Elsevier B.V. All rights reserved.
Lenticular neovascularization subsequent to traumatic cataract formation.
Kabat, Alan G
2011-09-01
To report a series of cases involving neovascularization within the human crystalline lens-a normally avascular structure-after ocular trauma. This is a retrospective, consecutive observational case series with review of the prevailing literature. Four individuals with a history of ocular trauma and subsequent cataract development were examined between May 2004 and April 2007. All had hypermature cataracts and intraocular inflammation, presumably secondary to phacolysis; two of the four had concurrent hyphema and ocular hypertension in the involved eye. All subjects in this series were found to display a discrete network of blood vessels within the structure of the crystalline lens, just beneath the anterior lens capsule. Neovascularization of the crystalline lens has received little attention in the ophthalmic literature, having been described only rarely in individual case reports. This manuscript details the first known case series involving lenticular neovascularization, and offers insight into its possible developmental mechanism.
Chan, Stefanie M; Svitova, Tatyana F; Lin, Meng C
2017-01-01
Contact lens discomfort is a common problem that can lead to unsuccessful or limited contact lens wear. Although many factors may contribute to contact lens discomfort, limited research has explored the influence of ethnicity-related differences in the anatomy and physiology of the ocular surface. Therefore, we performed a search of the literature in PubMed using key words related to "ocular surface" paired with the terms "race" and "ethnicity." The goal of this review was to determine potential areas of research regarding ethnicity differences, particularly between Asian and non-Asian eyes, in ocular surface integrity to advance our understanding of contact lens discomfort.
A Role for Smoothened during Murine Lens and Cornea Development
Trogrlic, Lidia; Milevski, Stefan V.; Familari, Mary; Martinez, Gemma; de Iongh, Robb U
2014-01-01
Various studies suggest that Hedgehog (Hh) signalling plays roles in human and zebrafish ocular development. Recent studies (Kerr et al., Invest Ophthalmol Vis Sci. 2012; 53, 3316–30) showed that conditionally activating Hh signals promotes murine lens epithelial cell proliferation and disrupts fibre differentiation. In this study we examined the expression of the Hh pathway and the requirement for the Smoothened gene in murine lens development. Expression of Hh pathway components in developing lens was examined by RT-PCR, immunofluorescence and in situ hybridisation. The requirement of Smo in lens development was determined by conditional loss-of-function mutations, using LeCre and MLR10 Cre transgenic mice. The phenotype of mutant mice was examined by immunofluorescence for various markers of cell cycle, lens and cornea differentiation. Hh pathway components (Ptch1, Smo, Gli2, Gli3) were detected in lens epithelium from E12.5. Gli2 was particularly localised to mitotic nuclei and, at E13.5, Gli3 exhibited a shift from cytosol to nucleus, suggesting distinct roles for these transcription factors. Conditional deletion of Smo, from ∼E12.5 (MLR10 Cre) did not affect ocular development, whereas deletion from ∼E9.5 (LeCre) resulted in lens and corneal defects from E14.5. Mutant lenses were smaller and showed normal expression of p57Kip2, c-Maf, E-cadherin and Pax6, reduced expression of FoxE3 and Ptch1 and decreased nuclear Hes1. There was normal G1-S phase but decreased G2-M phase transition at E16.5 and epithelial cell death from E14.5-E16.5. Mutant corneas were thicker due to aberrant migration of Nrp2+ cells from the extraocular mesenchyme, resulting in delayed corneal endothelial but normal epithelial differentiation. These results indicate the Hh pathway is required during a discrete period (E9.5–E12.5) in lens development to regulate lens epithelial cell proliferation, survival and FoxE3 expression. Defective corneal development occurs secondary to defects in lens and appears to be due to defective migration of peri-ocular Nrp2+ neural crest/mesenchymal cells. PMID:25268479
Thermal Interaction of Contact Lens Eyewear and 94 GHz Ocular Exposures
2008-09-01
AFRL-RH-BR-TR-2008-0071 ` Thermal Interaction of Contact Lens Eyewear and 94 GHz Ocular Exposures John D’Andrea Carrie C. Crane...THERMAL INTERACTION OF CONTACT LENS EYEWEAR AND 94 GHz OCULAR EXPOSURES D’Andrea JA 1, Crane CC1, Hatcher DJ1, Marchello DR1, Ziriax JM1...MM-YYYY) 12-20-2005 2. REPORT TYPE Technical Report 3. DATES COVERED (From - To) 2004-2005 THERMAL INTERACTION OF CONTACT LENS EYEWEAR AND 94
Modeling of mouse eye and errors in ocular parameters affecting refractive state
NASA Astrophysics Data System (ADS)
Bawa, Gurinder
Rodents eye are particularly used to study refractive error state of an eye and development of refractive eye. Genetic organization of rodents is similar to that of humans, which makes them interesting candidates to be researched upon. From rodents family mice models are encouraged over rats because of availability of genetically engineered models. Despite of extensive work that has been performed on mice and rat models, still no one is able to quantify an optical model, due to variability in the reported ocular parameters. In this Dissertation, we have extracted ocular parameters and generated schematics of eye from the raw data from School of Medicine, Detroit. In order to see how the rays would travel through an eye and the defects associated with an eye; ray tracing has been performed using ocular parameters. Finally we have systematically evaluated the contribution of various ocular parameters, such as radii of curvature of ocular surfaces, thicknesses of ocular components, and refractive indices of ocular refractive media, using variational analysis and a computational model of the rodent eye. Variational analysis revealed that variation in all the ocular parameters does affect the refractive status of the eye, but depending upon the magnitude of the impact those parameters are listed as critical or non critical. Variation in the depth of the vitreous chamber, thickness of the lens, radius of the anterior surface of the cornea, radius of the anterior surface of the lens, as well as refractive indices for the lens and vitreous, appears to have the largest impact on the refractive error and thus are categorized as critical ocular parameters. The radii of the posterior surfaces of the cornea and lens have much smaller contributions to the refractive state, while the radii of the anterior and posterior surfaces of the retina have no effect on the refractive error. These data provide the framework for further refinement of the optical models of the rat and mouse eye and suggest that extra efforts should be directed towards increasing the linear resolution of the rodent eye biometry and obtaining more accurate data for the refractive indices of the lens and vitreous.
[Ocular and visual alterations in computer workers contact lens wearers: scoping review].
Tauste Francés, Ana; Ronda-Pérez, Elena; Seguí Crespo, María del Mar
2014-01-01
The high number of computer workers wearing contact lenses raises the question whether the sum of these two risk factors for eye health may cause a worsening of Computer Vision Syndrome. The aim of this review is to synthesize the knowledge about ocular and visual alterations related with computer use in contact lens wearers. International review of scientific papers (2003-2013) in Spanish and English, using Scoping Review method, in Medline through PubMed and in Scopus. The initial search provided 114 references, after applying inclusion/exclusion criteria six of them were included. All of them reveal that symptoms when using computer are more prevalent in contact lens wearers, with values of symptoms presentation prevalence ranging from 95.0% to 16.9% in wearers and from 57.5% to 9.9% in non-wearers, and four times more likely to develop dry eye [OR: 4.07 (95% CI: 3.52 to 4.71)]. Computer workers suffer more ocular and visual disturbances if they also are contact lens users, but studies are few and non conclusive. Likewise, further research regarding contact lens type and their conditions of use, both in symptoms and tear quality and ocular surface are needed. Silicone hydrogel lenses are associated with more comfort.
Cytokine changes in tears and relationship to contact lens discomfort.
Willcox, Mark D P; Zhao, Zhenjun; Naduvilath, Thomas; Lazon de la Jara, Percy
2015-01-01
To determine the reproducibility of a multiplex bead assay for measuring cytokines in tears and correlations between ocular discomfort with or without contact lens wear and the concentration of cytokines in tears. Ninety participants (divided into two groups) were enrolled in this prospective study. They were asked to rate their ocular comfort and collect their tears in the morning and just before sleep for 10 days with or without contact lenses. The participants collected their tears using a glass microcapillary tube for both stages. Galyfilcon A lenses were worn on a daily disposable basis during the contact lens stage, and comfort scores and tears were collected before lens insertion and prior to lens removal at the end of the day. Tears were analyzed for cytokine concentrations using a 27-plex multibead assay. Correlations were sought between cytokine concentrations and comfort. There was a significant (p<0.022) decrease in ocular comfort over the day with or without lens wear. The magnitude of ocular discomfort was significantly greater (p<0.009) with lens wear. The concentrations of 12 cytokines differed significantly between the groups; thus, these cytokines were not analyzed further. For the remaining 15 cytokines, interleukin-8 (IL-8) was the only cytokine that changed in both groups during the day without (reduced by >-0.5 Log pg/ml, p<0.001) or with lens wear (reduced by >-0.2 Log pg/ml, p<0.001). The change in the vascular endothelial growth factor (VEGF) concentration only in tears was correlated to ocular comfort, but this was not changed by contact lens wear. Ocular comfort during the day is magnified by contact lens wear. However, the increase in the change in comfort during lens wear was not associated with changes in 15 cytokines in the tear film.
Melimine-Coated Antimicrobial Contact Lenses Reduce Microbial Keratitis in an Animal Model.
Dutta, Debarun; Vijay, Ajay K; Kumar, Naresh; Willcox, Mark D P
2016-10-01
To determine the ability of antimicrobial peptide melimine-coated contact lenses to reduce the incidence of microbial keratitis (MK) in a rabbit model of contact lens wear. In vitro antimicrobial activity of melimine-coated contact lenses was determined against Pseudomonas aeruginosa by viable count and a radiolabeled assay. The amount of lipopolysaccharide (LPS) associated with bacteria bound to melimine-coated and control lenses was determined. Ocular swabs from rabbit eyes were collected for assessment of ocular microflora. A rabbit model for MK was developed that used overnight wear of contact lenses colonized by P. aeruginosa in the absence of a corneal scratch. During lens wear, detailed ocular examinations were performed, and the incidence of MK was investigated. Bacteria associated with worn lenses and infected corneas were determined by viable plate count. Inhibition in viable and total P. aeruginosa adhesion by melimine-coated contact lenses was 3.1 log10 and 0.4 log10, respectively. After colonization, the amount of LPS on lenses was approximately the same with or without melimine. Gram-positive bacteria were found in all the ocular swabs followed by fungus (42%). Melimine-coated lens wear was protective and significantly (odds ratio 10.12; P = 0.012) reduced the incidence of P. aeruginosa-driven MK in the rabbit model. The antimicrobial lenses were associated with significantly (P < 0.001) lower ocular scores, indicating improved ocular signs compared with controls. This study showed that contaminated contact lenses can produce MK without corneal epithelial defect in an animal model. Melimine-coated contact lenses reduced the incidence of MK associated with P. aeruginosa in vivo. Development of MK requires viable bacteria adherent to contact lenses, and bacterial debris adherent at the lens surface did not cause keratitis.
Crystalline lens paradoxes revisited: significance of age-related restructuring of the GRIN.
Sheil, Conor J; Goncharov, Alexander V
2017-09-01
The accommodating volume-constant age-dependent optical (AVOCADO) model of the crystalline lens is used to explore the age-related changes in ocular power and spherical aberration. The additional parameter m in the GRIN lens model allows decoupling of the axial and radial GRIN profiles, and is used to stabilise the age-related change in ocular power. Data for age-related changes in ocular geometry and lens parameter P in the axial GRIN profile were taken from published experimental data. In our age-dependent eye model, the ocular refractive power shows behaviour similar to the previously unexplained "lens paradox". Furthermore, ocular spherical aberration agrees with the data average, in contrast to the proposed "spherical aberration paradox". The additional flexibility afforded by parameter m , which controls the ratio of the axial and radial GRIN profile exponents, has allowed us to study the restructuring of the lens GRIN medium with age, resulting in a new interpretation of the origin of the power and spherical aberration paradoxes. Our findings also contradict the conceptual idea that the ageing eye is similar to the accommodating eye.
Danysh, Brian P.; Duncan, Melinda K.
2009-01-01
The lens capsule is a modified basement membrane that completely surrounds the ocular lens. It is known that this extracellular matrix is important for both the structure and biomechanics of the lens in addition to providing informational cues to maintain lens cell phenotype. This review covers the development and structure of the lens capsule, lens diseases associated with mutations in extracellular matrix genes and the role of the capsule in lens function including those proposed for visual accommodation, selective permeability to infectious agents, and cell signaling. PMID:18773892
Cytokine changes in tears and relationship to contact lens discomfort
Zhao, Zhenjun; Naduvilath, Thomas; Lazon de la Jara, Percy
2015-01-01
Purpose To determine the reproducibility of a multiplex bead assay for measuring cytokines in tears and correlations between ocular discomfort with or without contact lens wear and the concentration of cytokines in tears. Methods Ninety participants (divided into two groups) were enrolled in this prospective study. They were asked to rate their ocular comfort and collect their tears in the morning and just before sleep for 10 days with or without contact lenses. The participants collected their tears using a glass microcapillary tube for both stages. Galyfilcon A lenses were worn on a daily disposable basis during the contact lens stage, and comfort scores and tears were collected before lens insertion and prior to lens removal at the end of the day. Tears were analyzed for cytokine concentrations using a 27-plex multibead assay. Correlations were sought between cytokine concentrations and comfort. Results There was a significant (p<0.022) decrease in ocular comfort over the day with or without lens wear. The magnitude of ocular discomfort was significantly greater (p<0.009) with lens wear. The concentrations of 12 cytokines differed significantly between the groups; thus, these cytokines were not analyzed further. For the remaining 15 cytokines, interleukin-8 (IL-8) was the only cytokine that changed in both groups during the day without (reduced by >-0.5 Log pg/ml, p<0.001) or with lens wear (reduced by >-0.2 Log pg/ml, p<0.001). The change in the vascular endothelial growth factor (VEGF) concentration only in tears was correlated to ocular comfort, but this was not changed by contact lens wear. Conclusions Ocular comfort during the day is magnified by contact lens wear. However, the increase in the change in comfort during lens wear was not associated with changes in 15 cytokines in the tear film. PMID:25814827
Ophthalmic applications of confocal microscopy: diagnostics, refractive surgery, and eye banking
NASA Astrophysics Data System (ADS)
Masters, Barry R.
1990-11-01
Confocal microscopy of ocular tissue provides two advantages over traditional imaging techniques: increased range and transverse resolution and increased contrast. The semitransparent cornea and ocular lens in the living eye can be optically sectioned and observed by reflected light confocal microscopy. Within the cornea we observed various cell components nerve fibers nerve cell bodies and fibrous networks. The confocal microscopic images from the in-situ ocular lens show the lens capsule the lens epithelium and the individual lens fibrils. All of the reflected light confocal microscopic images have high contrast and high resolution. Some of the applications of confocal imaging in ophthalmology include: diagnostics of the cornea and the ocular lens examination prior to and after refractive surgery examination of intraocular lenses (IOL) and examination of eye bank material. Other ophthalmic uses of confocal imaging include: studies of wound healing therapeutics and the effects of contact lenses on the cornea. The proposed features of a clinical confocal microscope are reviewed. 2.
Ocular screening tests of elementary school children
NASA Technical Reports Server (NTRS)
Richardson, J.
1983-01-01
This report presents an analysis of 507 abnormal retinal reflex images taken of Huntsville kindergarten and first grade students. The retinal reflex images were obtained by using an MSFC-developed Generated Retinal Reflex Image System (GRRIS) photorefractor. The system uses a 35 mm camera with a telephoto lens with an electronic flash attachment. Slide images of the eyes were examined for abnormalities. Of a total of 1835 students screened for ocular abnormalities, 507 were found to have abnormal retinal reflexes. The types of ocular abnormalities detected were hyperopia, myopia, astigmatism, esotropia, exotropia, strabismus, and lens obstuctions. The report shows that the use of the photorefractor screening system is an effective low-cost means of screening school children for abnormalities.
Tauste, Ana; Ronda, Elena; Baste, Valborg; Bråtveit, Magne; Moen, Bente E; Seguí Crespo, María-Del-Mar
2018-04-01
To analyze differences in the ocular surface appearance and tear film status of contact lens wearers and non-wearers in a group of visual display terminals (VDT) workers and additionally to assess differences between lens materials. Cross-sectional study of 236 office workers, of whom 92 were contact lens wearers. Workers provided information on their contact lenses (conventional hydrogel, silicone hydrogel or rigid gas permeable lenses) and exposure to VDT at work. Ocular surface and tear film status were determined by the presence of bulbar, limbal and lid redness, lid roughness and corneal staining type, and by Schirmer's and tear break-up time tests (TBUT). A generalized linear model was used to calculate the crude (cRR) and age- and sex-adjusted (aRR) relative risk to measure the association between ocular surface and tear film abnormalities and contact lens use and type. The aRR of ocular surface abnormalities was higher in contact lens wearers compared to non-wearers: bulbar redness (aRR 1.69; 95% CI 1.25-2.30), limbal redness (aRR 2.87; 1.88-4.37), lid redness (aRR 2.53; 1.35-4.73) and lid roughness (aRR 7.03; 1.31-37.82). VDT exposure > 4 h/day increased wearers' risk of limbal and lid redness. Conventional hydrogel wearers had the highest risk of ocular surface abnormalities, followed by silicone hydrogel wearers. Both contact and non-contact lens wearers had a high prevalence of altered TBUT (77.3 and 75.7% respectively) and Schirmer (51.8 and 41.3%). Regular contact lens use during VDT exposure at work increases risk of bulbar, limbal and lid redness, and lid roughness, especially in soft contact lens wearers. The high prevalence of altered TBUT and Schirmer's results in all participants suggests that VDT use greatly affects tear film characteristics.
An Exploration into Diffusion Tensor Imaging in the Bovine Ocular Lens
Vaghefi, Ehsan; Donaldson, Paul J.
2013-01-01
We describe our development of the diffusion tensor imaging modality for the bovine ocular lens. Diffusion gradients were added to a spin-echo pulse sequence and the relevant parameters of the sequence were refined to achieve good diffusion weighting in the lens tissue, which demonstrated heterogeneous regions of diffusive signal attenuation. Decay curves for b-value (loosely summarizes the strength of diffusion weighting) and TE (determines the amount of magnetic resonance imaging-obtained signal) were used to estimate apparent diffusion coefficients (ADC) and T2 in different lens regions. The ADCs varied by over an order of magnitude and revealed diffusive anisotropy in the lens. Up to 30 diffusion gradient directions, and 8 signal acquisition averages, were applied to lenses in culture in order to improve maps of diffusion tensor eigenvalues, equivalent to ADC, across the lens. From these maps, fractional anisotropy maps were calculated and compared to known spatial distributions of anisotropic molecular fluxes in the lens. This comparison suggested new hypotheses and experiments to quantitatively assess models of circulation in the avascular lens. PMID:23459990
Requirement of Smad4 from Ocular Surface Ectoderm for Retinal Development.
Li, Jing; Wang, Shusheng; Anderson, Chastain; Zhao, Fangkun; Qin, Yu; Wu, Di; Wu, Xinwei; Liu, Jia; He, Xuefei; Zhao, Jiangyue; Zhang, Jinsong
2016-01-01
Microphthalmia is characterized by abnormally small eyes and usually retinal dysplasia, accounting for up to 11% of the blindness in children. Right now there is no effective treatment for the disease, and the underlying mechanisms, especially how retinal dysplasia develops from microphthalmia and whether it depends on the signals from lens ectoderm are still unclear. Mutations in genes of the TGF-β superfamily have been noted in patients with microphthalmia. Using conditional knockout mice, here we address the question that whether ocular surface ectoderm-derived Smad4 modulates retinal development. We found that loss of Smad4 specifically on surface lens ectoderm leads to microphthalmia and dysplasia of retina. Retinal dysplasia in the knockout mice is caused by the delayed or failed differentiation and apoptosis of retinal cells. Microarray analyses revealed that members of Hedgehog and Wnt signaling pathways are affected in the knockout retinas, suggesting that ocular surface ectoderm-derived Smad4 can regulate Hedgehog and Wnt signaling in the retina. Our studies suggest that defective of ocular surface ectoderm may affect retinal development.
Requirement of Smad4 from Ocular Surface Ectoderm for Retinal Development
Li, Jing; Wang, Shusheng; Anderson, Chastain; Zhao, Fangkun; Qin, Yu; Wu, Di; Wu, Xinwei; Liu, Jia; He, Xuefei; Zhao, Jiangyue; Zhang, Jinsong
2016-01-01
Microphthalmia is characterized by abnormally small eyes and usually retinal dysplasia, accounting for up to 11% of the blindness in children. Right now there is no effective treatment for the disease, and the underlying mechanisms, especially how retinal dysplasia develops from microphthalmia and whether it depends on the signals from lens ectoderm are still unclear. Mutations in genes of the TGF-β superfamily have been noted in patients with microphthalmia. Using conditional knockout mice, here we address the question that whether ocular surface ectoderm-derived Smad4 modulates retinal development. We found that loss of Smad4 specifically on surface lens ectoderm leads to microphthalmia and dysplasia of retina. Retinal dysplasia in the knockout mice is caused by the delayed or failed differentiation and apoptosis of retinal cells. Microarray analyses revealed that members of Hedgehog and Wnt signaling pathways are affected in the knockout retinas, suggesting that ocular surface ectoderm-derived Smad4 can regulate Hedgehog and Wnt signaling in the retina. Our studies suggest that defective of ocular surface ectoderm may affect retinal development. PMID:27494603
Wolffsohn, James; Hall, Lee; Mroczkowska, Stephanie; Hunt, Olivia A; Bilkhu, Paramdeep; Drew, Tom; Sheppard, Amy
2015-10-01
To quantify the end-of-day silicone-hydrogel daily disposable contact lens fit and its influence of on ocular comfort, physiology and lens wettability. Thirty-nine subjects (22.1±3.5 years) were randomised to wear each of 3 silicone-hydrogel daily-disposable contact lenses (narafilcon A, delefilcon A and filcon II 3), bilaterally, for one week. Lens fit was assessed objectively using a digital video slit-lamp at 8, 12 and 16h after lens insertion. Hyperaemia, non-invasive tear break-up time, tear meniscus height and comfort were also evaluated at these timepoints, while corneal and conjunctival staining were assessed on lens removal. Lens fit assessments were not different between brands (P>0.05), with the exception of the movement at blink where narafilcon A was more mobile. Overall, lag reduced but push-up speed increased from 8 to 12h (P<0.05), but remained stable from 12 to 16h (P>0.05). Movement-on-blink was unaffected by wear-time (F=0.403, P=0.670). A more mobile lens fit with one brand did not indicate that person would have a more mobile fit with another brand (r=-0.06 to 0.63). Lens fit was not correlated with comfort, ocular physiology or lens wettability (P>0.01). Among the lenses tested, objective lens fit changed between 8h and 12h of lens wear. The weak correlation in individual lens fit between brands indicates that fit is dependent on more than ocular shape. Consequently, substitution of a different lens brand with similar parameters will not necessarily provide comparable lens fit. Copyright © 2015 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
Golebiowski, Blanka; Papas, Eric B; Stapleton, Fiona
2012-03-09
Deprivation of oxygen to the ocular surface during contact lens wear has been implicated in the alteration of sensory function. This study investigates whether increasing oxygen availability through discontinuation of contact lens wear or transfer into highly oxygen transmissible (high Dk/t) lenses leads to a change in corneal or conjunctival sensitivity. Twenty-seven long-term extended wearers of low Dk/t soft contact lenses ceased lens wear for 1 week and were refitted with high Dk/t silicone hydrogel lenses. A control group of 25 nonwearers matched for age and sex was also recruited. Central corneal and inferior conjunctival sensitivity were measured using an air-jet aesthesiometer. Threshold was determined using a staircase technique. Measurements were taken during low Dk/t lens wear; after 1 week of no wear; and after 1, 3, 6, and 12 months of high Dk/t lens wear. Measurements were carried out on one occasion on the nonwearers. Corneal sensitivity decreased 1 week after discontinuation of low Dk/t lenses and no further change in sensitivity occurred with high Dk/t lens wear. Conjunctival sensitivity did not change over the same time frame. Ocular surface sensitivity in long-term low Dk/t soft lens wearers was similar to that of nonwearers. Sensitivity was higher in females than males in the nonwearers, but not in the lens-wearing group. An interaction of sex on change in conjunctival threshold was found in the lens wearers. These findings indicate that factors other than oxygen availability alone determine sensitivity of the ocular surface. Silicone hydrogel contact lenses appear to have only a minor impact on ocular surface sensitivity in previous lens wearers.
Loss of Sip1 leads to migration defects and retention of ectodermal markers during lens development.
Manthey, Abby L; Lachke, Salil A; FitzGerald, Paul G; Mason, Robert W; Scheiblin, David A; McDonald, John H; Duncan, Melinda K
2014-02-01
SIP1 encodes a DNA-binding transcription factor that regulates multiple developmental processes, as highlighted by the pleiotropic defects observed in Mowat-Wilson syndrome, which results from mutations in this gene. Further, in adults, dysregulated SIP1 expression has been implicated in both cancer and fibrotic diseases, where it functionally links TGFβ signaling to the loss of epithelial cell characteristics and gene expression. In the ocular lens, an epithelial tissue important for vision, Sip1 is co-expressed with epithelial markers, such as E-cadherin, and is required for the complete separation of the lens vesicle from the head ectoderm during early ocular morphogenesis. However, the function of Sip1 after early lens morphogenesis is still unknown. Here, we conditionally deleted Sip1 from the developing mouse lens shortly after lens vesicle closure, leading to defects in coordinated fiber cell tip migration, defective suture formation, and cataract. Interestingly, RNA-Sequencing analysis on Sip1 knockout lenses identified 190 differentially expressed genes, all of which are distinct from previously described Sip1 target genes. Furthermore, 34% of the genes with increased expression in the Sip1 knockout lenses are normally downregulated as the lens transitions from the lens vesicle to early lens, while 49% of the genes with decreased expression in the Sip1 knockout lenses are normally upregulated during early lens development. Overall, these data imply that Sip1 plays a major role in reprogramming the lens vesicle away from a surface ectoderm cell fate towards that necessary for the development of a transparent lens and demonstrate that Sip1 regulates distinctly different sets of genes in different cellular contexts. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Loss of Sip1 leads to migration defects and retention of ectodermal markers during lens development
Manthey, Abby L.; Lachke, Salil A.; FitzGerald, Paul G.; Mason, Robert W.; Scheiblin, David A.; McDonald, John H.; Duncan, Melinda K.
2014-01-01
SIP1 encodes a DNA-binding transcription factor that regulates multiple developmental processes, as highlighted by the pleiotropic defects observed in Mowat-Wilson Syndrome, which results from mutations in this gene. Further, in adults, dysregulated SIP1 expression has been implicated in both cancer and fibrotic diseases, where it functionally links TGFβ signaling to the loss of epithelial cell characteristics and gene expression. In the ocular lens, an epithelial tissue important for vision, Sip1 is co-expressed with epithelial markers, such as E-cadherin, and is required for the complete separation of the lens vesicle from the head ectoderm during early ocular morphogenesis. However, the function of Sip1 after early lens morphogenesis is still unknown. Here, we conditionally deleted Sip1 from the developing mouse lens shortly after lens vesicle closure, leading to defects in coordinated fiber cell tip migration, defective suture formation, and cataract. Interestingly, RNA-Sequencing analysis on Sip1 knockout lenses identified 190 differentially expressed genes, all of which are distinct from previously described Sip1 target genes. Furthermore, 34% of the genes with increased expression in the Sip1 knockout lenses are normally downregulated as the lens transitions from the lens vesicle to early lens, while 49% of the genes with decreased expression in the Sip1 knockout lenses are normally upregulated during early lens development. Overall, these data imply that Sip1 plays a major role in reprogramming the lens vesicle away from a surface ectoderm cell fate towards that necessary for the development of a transparent lens and demonstrate that Sip1 regulates distinctly different sets of genes in different cellular contexts. PMID:24161570
Sengor, Tomris; Aydin Kurna, Sevda; Ozbay, Nurver; Ertek, Semahat; Aki, Suat; Altun, Ahmet
2012-01-01
To evaluate ocular surface changes in long-term silicone hydrogel contact lens wearers. Thirty patients were included in this study. Twenty patients (40 eyes) using contact lenses constituted group 1 and 10 (20 eyes) volunteers constituted group 2. The duration of average contact lens usage was 7.74 ± 3.3 years. Ocular surface was evaluated by surface staining, tear film break-up time (TBUT), Schirmer I test, and conjunctival impression cytology with color-coded mapping technique and by the Ocular Surface Disease Index (OSDI). The mean break-up time was lower and staining scores were higher in group 1 (p<0.001) but Schirmer values were not significantly different from group 2 (p>0.05). The mean OSDI score was 34.59 ± 11.93 to 19.28 ± 6.7 in group 1 and 2. Increased metaplastic predominant changes of grade II and III were observed in the interpalpebral and perilimbal areas in group 1. Significant correlations were observed in TBUT, cornea staining, and grade II to grade III metaplasia ratios between duration of the lens usage and contact lens wear time in a day. Silicone hydrogel lenses produce significant changes on tear film and impression cytology of the ocular surface in long-term use.
Application of erbium: YAG laser in ocular ablation.
Tsubota, K
1990-01-01
Recent developments in lasers have provided us the possibility of laser ocular surgery. The xenon, argon, neodymium:YAG and dye lasers have been successfully used in out-patient clinics. The excimer laser has been attracting researchers' interest in the new application of laser to cornea and lens. The erbium:YAG laser emits a 2.94-microns beam that can ablate the transparent ocular tissues such as lenses and corneas. The author has applied this laser to the cornea, lens, vitreous and other ocular tissues. The erbium:YAG laser beam was directed through a 1.5-meter-long, 200-microns-diameter fiberoptic guide. The radiant energy measured about 50 mJ at the end of the probe. The laser was emitted as a 400-microsecond pulse. Freshly enucleated rabbit eyes were used in this study. Laser burns were applied to the tissue surface at various energy settings. At minimal power, the tissues were coagulated by the erbium:YAG laser application. At a power of more than 636-954 mJ/mm2, tissue began to evaporate; the tissue loss was observed under a surgical light microscope. Corneal photoablation, lens ablation, iridotomy, trabeculotomy, cutting of the vitreous and retinal ablation were easily performed. Like the excimer laser, the erbium:YAG laser is a potential tool for ocular surgery.
Crystalline lens and refractive development.
Iribarren, Rafael
2015-07-01
Individual refractive errors usually change along lifespan. Most children are hyperopic in early life. This hyperopia is usually lost during growth years, leading to emmetropia in adults, but myopia also develops in children during school years or during early adult life. Those subjects who remain emmetropic are prone to have hyperopic shifts in middle life. And even later, at older ages, myopic shifts are developed with nuclear cataract. The eye grows from 15 mm in premature newborns to approximately 24 mm in early adult years, but, in most cases, refractions are maintained stable in a clustered distribution. This growth in axial length would represent a refractive change of more than 40 diopters, which is compensated by changes in corneal and lens powers. The process which maintains the balance between the ocular components of refraction during growth is still under study. As the lens power cannot be measured in vivo, but can only be calculated based on the other ocular components, there have not been many studies of lens power in humans. Yet, recent studies have confirmed that the lens loses power during growth in children, and that hyperopic and myopic shifts in adulthood may be also produced by changes in the lens. These studies in children and adults give a picture of the changing power of the lens along lifespan. Other recent studies about the growth of the lens and the complexity of its internal structure give clues about how these changes in lens power are produced along life. Copyright © 2015 Elsevier Ltd. All rights reserved.
The Significance of the Discordant Occurrence of Lens Tumors in Humans versus Other Species
Albert, Daniel M.; Phelps, Paul O.; Surapaneni, Krishna R.; Thuro, Bradley A.; Potter, Heather D.; Ikeda, Akihiro; Teixeira, Leandro B. C.; Dubielzig, Richard R.
2015-01-01
Purpose The purpose of this study was to determine in which species and under what conditions lens tumors occur. Design A review of data bases of available human and veterinary ocular pathological material and the previously reported literature. Participants Approximately 18,000 patients who had ocular surgical specimens submitted and studied at the University of Wisconsin School of Medicine and Public Health (UWSMPH) between 1920 and 2014 and 45,000 ocular veterinary cases from the Comparative Ocular Pathology Laboratory of Wisconsin (COPLOW) between 1983 and 2014. Methods Material in two major archived collections at the University of Wisconsin medical and veterinary schools were studied for occurrence of lens tumors. Tumor was defined as “a new growth of tissue characterized by progressive, uncontrolled proliferation of cells.” In addition, cases presented at 3 major eye pathology societies (Verhoeff-Zimmerman Ophthalmic Pathology Society, Eastern Ophthalmic Pathology Society, and The Armed Forces Institute of Pathology Ophthalmic Alumni Society) from 1975 through 2014 were reviewed. Finally, a careful search of the literature was carried out. Approval from the IRB to carry out this study was obtained. Main Outcome Measures The presence of tumors of the lens. Results The database search and literature review failed to find an example of a lens tumor in humans. In contrast, examples of naturally occurring lens tumors were found in cats, dogs, rabbits, and birds. 4.5% of feline intraocular and adnexal neoplasms (234/5153) in the veterinary school database were designated as feline ocular post-traumatic sarcoma (FOPTS), a tumor previously demonstrated to be of lens epithelial origin. Similar tumors were seen in rabbit eyes, a bird, and in a dog. All four species with lens tumors had a history of either ocular trauma or protracted uveitis. The literature search also revealed cases where lens tumors were induced in zebrafish, rainbow trout, hamsters, and mice, by carcinogenic agents (methylcholanthrene, thioacetamide), oncogenic viruses (SV40, HPV-16), and genetic manipulation. Conclusions Our results suggest that lens tumors do not occur in humans. In contrast, following lens capsule rupture, a lens tumor can occur in other species. We hypothesize that a genetic mechanism exists which prevents lens tumors in humans. PMID:26130328
The Role of Aquaporins in Ocular Lens Homeostasis
Schey, Kevin L.; Petrova, Rosica S.; Gletten, Romell B.; Donaldson, Paul J.
2017-01-01
Aquaporins (AQPs), by playing essential roles in the maintenance of ocular lens homeostasis, contribute to the establishment and maintenance of the overall optical properties of the lens over many decades of life. Three aquaporins, AQP0, AQP1 and AQP5, each with distinctly different functional properties, are abundantly and differentially expressed in the different regions of the ocular lens. Furthermore, the diversity of AQP functionality is increased in the absence of protein turnover by age-related modifications to lens AQPs that are proposed to alter AQP function in the different regions of the lens. These regional differences in AQP functionality are proposed to contribute to the generation and directionality of the lens internal microcirculation; a system of circulating ionic and fluid fluxes that delivers nutrients to and removes wastes from the lens faster than could be achieved by passive diffusion alone. In this review, we present how regional differences in lens AQP isoforms potentially contribute to this microcirculation system by highlighting current areas of investigation and emphasizing areas where future work is required. PMID:29231874
A rare case of traumatic subretinal migration of crystalline lens, corroborated histologically.
Bawankar, Pritam; Das, Dipankar; Agarwal, Balmukund; Bhattacharjee, Kasturi; Tayab, Shahinur; Deka, Panna; Singh, Anshul; Borah, Erani; Dhar, Shriya
2017-12-01
Blunt trauma is the most common cause of posterior dislocation of the crystalline lens. We describe a rare case of subretinal migration of crystalline lens through the giant retinal tear following blunt ocular trauma. This incidental finding of subretinal dislocation of lens following blunt ocular trauma was confirmed on histopathological examination of the enucleated eye. This complication has not been described by histopathological examination in literature so far.
A rare case of traumatic subretinal migration of crystalline lens, corroborated histologically
Bawankar, Pritam; Das, Dipankar; Agarwal, Balmukund; Bhattacharjee, Kasturi; Tayab, Shahinur; Deka, Panna; Singh, Anshul; Borah, Erani; Dhar, Shriya
2017-01-01
Blunt trauma is the most common cause of posterior dislocation of the crystalline lens. We describe a rare case of subretinal migration of crystalline lens through the giant retinal tear following blunt ocular trauma. This incidental finding of subretinal dislocation of lens following blunt ocular trauma was confirmed on histopathological examination of the enucleated eye. This complication has not been described by histopathological examination in literature so far. PMID:29208844
NASA Astrophysics Data System (ADS)
Petta, V.; Pharmakakis, N.; Papatheodorou, G. N.; Yannopoulos, S. N.
2008-06-01
We present a detailed dynamic light scattering study of the phase separation in the ocular lens emerging during cold cataract development. Cold cataract is a phase separation effect that proceeds via spinodal decomposition of the lens cytoplasm with cooling. The intensity autocorrelation functions of the lens protein content are analyzed with the aid of two methods, providing information on the populations and dynamics of the scattering elements associated with cold cataract. It is found that the temperature dependence of many measurable parameters changes appreciably at the characteristic temperature ˜16±1°C which is associated with the onset of cold cataract. By extending the temperature range of this work to previously inaccessible regimes, i.e., well below the phase separation or coexistence curve at Tcc , we have been able to accurately determine the temperature dependence of the collective and self-diffusion coefficients of proteins near the spinodal. The analysis showed that the dynamics of proteins bears some resemblance to the dynamics of structural glasses, where the apparent activation energy for particle diffusion increases below Tcc , indicating a highly cooperative motion. Application of ideas developed for studying the critical dynamics of binary protein-solvent mixtures, as well as the use of a modified Arrhenius equation, enabled us to estimate the spinodal temperature Tsp of the lens nucleus. The applicability of dynamic light scattering as a noninvasive, early-diagnostic tool for ocular diseases is also demonstrated in light of the findings of the present paper.
Space radiation dose analysis for solar flare of August 1989
NASA Technical Reports Server (NTRS)
Nealy, John E.; Simonsen, Lisa C.; Sauer, Herbert H.; Wilson, John W.; Townsend, Lawrence W.
1990-01-01
Potential dose and dose rate levels to astronauts in deep space are predicted for the solar flare event which occurred during the week of August 13, 1989. The Geostationary Operational Environmental Satellite (GOES-7) monitored the temporal development and energy characteristics of the protons emitted during this event. From these data, differential fluence as a function of energy was obtained in order to analyze the flare using the Langley baryon transport code, BRYNTRN, which describes the interactions of incident protons in matter. Dose equivalent estimates for the skin, ocular lens, and vital organs for 0.5 to 20 g/sq cm of aluminum shielding were predicted. For relatively light shielding (less than 2 g/sq cm), the skin and ocular lens 30-day exposure limits are exceeded within several hours of flare onset. The vital organ (5 cm depth) dose equivalent is exceeded only for the thinnest shield (0.5 g/sq cm). Dose rates (rem/hr) for the skin, ocular lens, and vital organs are also computed.
Space radiation dose analysis for solar flare of August 1989
NASA Astrophysics Data System (ADS)
Nealy, John E.; Simonsen, Lisa C.; Sauer, Herbert H.; Wilson, John W.; Townsend, Lawrence W.
1990-12-01
Potential dose and dose rate levels to astronauts in deep space are predicted for the solar flare event which occurred during the week of August 13, 1989. The Geostationary Operational Environmental Satellite (GOES-7) monitored the temporal development and energy characteristics of the protons emitted during this event. From these data, differential fluence as a function of energy was obtained in order to analyze the flare using the Langley baryon transport code, BRYNTRN, which describes the interactions of incident protons in matter. Dose equivalent estimates for the skin, ocular lens, and vital organs for 0.5 to 20 g/sq cm of aluminum shielding were predicted. For relatively light shielding (less than 2 g/sq cm), the skin and ocular lens 30-day exposure limits are exceeded within several hours of flare onset. The vital organ (5 cm depth) dose equivalent is exceeded only for the thinnest shield (0.5 g/sq cm). Dose rates (rem/hr) for the skin, ocular lens, and vital organs are also computed.
Ocular Phenotype of Fbn2-Null Mice
Shi, Yanrong; Tu, Yidong; Mecham, Robert P.; Bassnett, Steven
2013-01-01
Purpose. Fibrillin-2 (Fbn2) is the dominant fibrillin isoform expressed during development of the mouse eye. To test its role in morphogenesis, we examined the ocular phenotype of Fbn2−/− mice. Methods. Ocular morphology was assessed by confocal microscopy using antibodies against microfibril components. Results. Fbn2−/− mice had a high incidence of anterior segment dysgenesis. The iris was the most commonly affected tissue. Complete iridal coloboma was present in 37% of eyes. Dyscoria, corectopia and pseudopolycoria were also common (43% combined incidence). In wild-type (WT) mice, fibrillin-2-rich microfibrils are prominent in the pupillary membrane (PM) during development. In Fbn2-null mice, the absence of Fbn2 was partially compensated for by increased expression of fibrillin-1, although the resulting PM microfibrils were disorganized, compared with WTs. In colobomatous adult Fbn2−/− eyes, the PM failed to regress normally, especially beneath the notched region of the iris. Segments of the ciliary body were hypoplastic, and zonular fibers, although relatively plentiful, were unevenly distributed around the lens equator. In regions where the zonular fibers were particularly disturbed, the synchronous differentiation of the underlying lens fiber cells was affected. Conclusions. Fbn2 has an indispensable role in ocular morphogenesis in mice. The high incidence of iris coloboma in Fbn2-null animals implies a previously unsuspected role in optic fissure closure. The observation that fiber cell differentiation was disturbed in Fbn2−/− mice raises the possibility that the attachment of zonular fibers to the lens surface may help specify the equatorial margin of the lens epithelium. PMID:24130178
Zöller, G; Figel, M; Denk, J; Schulz, K; Sabo, A
2016-03-01
Eye lens radiation exposure during radiologically-guided endoscopic procedures may result in radiation-induced cataracts; therefore, we investigated the ocular radiation exposure during ureteroscopy on a phantom model. Using an Alderson phantom model and eye lens dosimeters, we measured the ocular radiation exposure depending on the number of X-ray images and on the duration of fluoroscopic imaging. The measurements were done with and without using a face protection shield. We could demonstrate that a significant ocular radiation exposure can occur, depending on the number of X-ray images and on the duration time of fluoroscopy. Eye lens doses up to 0.025 mSv were recorded even using modern digital X-ray systems. Using face protection shields this ocular radiation exposure can be reduced to a minimum. The International Commission on Radiological Protection (ICRP) recommendations of a mean eye lens dosage of 20 mSv/year may be exceeded during repeated ureteroscopy by a high volume surgeon. Using a face protection shield, the eye lens dose during ureteroscopy could be reduced to a minimum in a phantom model. Further investigations will show whether these results can be transferred to real life ureteroscopic procedures.
Lin, Li-Ren; Leverenz, Victor R.; Dang, Loan
2011-01-01
Purpose. UVB radiation from sunlight is known to be a risk factor for human cataract. The purpose in this study was to investigate the ability of a class I UV-blocking soft contact lens to protect against UVB-induced effects on the ocular tissues of the rabbit in vivo. Methods. Eyes of rabbits were exposed to UVB light for 30 minutes (270–360 nm, peak at 310 nm, 1.7 mW/cm2 on the cornea). Eyes were irradiated in the presence of either a UV-blocking senofilcon A contact lens, a minimally UV-blocking lotrafilcon A contact lens, or no contact lens at all. Effects on the cornea and lens were evaluated at various times after exposure. Results. Eyes irradiated with no contact lens protection showed corneal epithelial cell loss plus lens epithelial cell swelling, vacuole formation, and DNA single-strand breaks, as well as lens anterior subcapsular opacification. The senofilcon A lens protected nearly completely against the UVB-induced effects, whereas the lotrafilcon A lens showed no protection. Conclusions. The results indicate that use of a senofilcon A contact lens is beneficial in protecting ocular tissues of the rabbit against the harmful effects of UVB light, including photokeratitis and cataract. PMID:21421866
Giblin, Frank J; Lin, Li-Ren; Leverenz, Victor R; Dang, Loan
2011-06-01
UVB radiation from sunlight is known to be a risk factor for human cataract. The purpose in this study was to investigate the ability of a class I UV-blocking soft contact lens to protect against UVB-induced effects on the ocular tissues of the rabbit in vivo. Eyes of rabbits were exposed to UVB light for 30 minutes (270-360 nm, peak at 310 nm, 1.7 mW/cm(2) on the cornea). Eyes were irradiated in the presence of either a UV-blocking senofilcon A contact lens, a minimally UV-blocking lotrafilcon A contact lens, or no contact lens at all. Effects on the cornea and lens were evaluated at various times after exposure. Eyes irradiated with no contact lens protection showed corneal epithelial cell loss plus lens epithelial cell swelling, vacuole formation, and DNA single-strand breaks, as well as lens anterior subcapsular opacification. The senofilcon A lens protected nearly completely against the UVB-induced effects, whereas the lotrafilcon A lens showed no protection. The results indicate that use of a senofilcon A contact lens is beneficial in protecting ocular tissues of the rabbit against the harmful effects of UVB light, including photokeratitis and cataract.
Ke, Bilian; Mao, Xinjie; Jiang, Hong; He, Jichang; Liu, Che; Li, Min; Yuan, Ying
2017-01-01
Purpose This study investigated the anterior ocular anatomic origin of high-order aberration (HOA) components using optical coherence tomography and a Shack-Hartmann wavefront sensor. Methods A customized system was built to simultaneously capture images of ocular wavefront aberrations and anterior ocular biometry. Relaxed, 2-diopter (D) and 4-D accommodative states were repeatedly measured in 30 young subjects. Custom software was used to correct optical distortions and measure biometric parameters from the images. Results The anterior ocular biometry changed during 2-D accommodation, in which central lens thickness, ciliary muscle thicknesses at 1 mm posterior to the scleral spur (CMT1), and the maximum value of ciliary muscle thickness increased significantly, whereas anterior chamber depth, CMT3, radius of anterior lens surface curvature (RAL), and radius of posterior lens surface curvature (RPL) decreased significantly. The changes in the anterior ocular parameters during 4-D accommodation were similar to those for the 2-D accommodation. \\begin{document}\
ELECTRICAL SIGNALING IN CONTROL OF OCULAR CELL BEHAVIORS
Zhao, Min; Chalmers, Laura; Cao, Lin; Viera, Ana C.; Mannis, Mark; Reid, Brian
2011-01-01
Epithelia of the cornea, lens and retina contain a vast array of ion channels and pumps. Together they produce a polarized flow of ions in and out of cells, as well as across the epithelia. These naturally occurring ion fluxes are essential to the hydration and metabolism of the ocular tissues, especially for the avascular cornea and lens. The directional transport of ions generates electric fields and currents in those tissues. Applied electric fields affect migration, division and proliferation of ocular cells which are important in homeostasis and healing of the ocular tissues. Abnormalities in any of those aspects may underlie many ocular diseases, for example chronic corneal ulcers, posterior capsule opacity after cataract surgery, and retinopathies. Electric field-inducing cellular responses, termed electrical signaling here, therefore may be an unexpected yet powerful mechanism in regulating ocular cell behavior. Both endogenous electric fields and applied electric fields could be exploited to regulate ocular cells. We aim to briefly describe the physiology of the naturally occurring electrical activities in the corneal, lens, and retinal epithelia, to provide experimental evidence of the effects of electric fields on ocular cell behaviors, and to suggest possible clinical implications. PMID:22020127
Microbial Keratitis: Could Contact Lens Material Affect Disease Pathogenesis?
Evans, David J.; Fleiszig, Suzanne M. J.
2012-01-01
Microbial keratitis is a sight-threatening complication associated with contact lenses. The introduction of silicone hydrogel lens materials with increased oxygen transmission to the ocular surface has not significantly altered the incidence of microbial keratitis. These data suggest that alternate, or additional, predisposing factors involving lens wear must be addressed to reduce or eliminate these infections. The contact lens can provide a surface for microbial growth in situ, and can also influence ocular surface homeostasis through effects on the tear fluid and corneal epithelium. Thus, it is intuitive that future contact lens materials could make a significant contribution to preventing microbial keratitis. Design of the “right” material to prevent microbial keratitis requires understanding the effects of current materials on bacterial virulence in the cornea, and on ocular surface innate defenses. Current knowledge in each of these areas will be presented, with a discussion of future directions needed to understand the influence of lens material on the pathogenesis of microbial keratitis. PMID:23266587
Eye model for the ground squirrel
NASA Astrophysics Data System (ADS)
Sussman, Dafna; Chou, B. Ralph; Lakshminarayanan, Vasudevan
2011-11-01
This paper presents an anatomically-correct eye model for the ground squirrel, a diurnal, highly-developed mammal with high visual acuity. This model can assist in understanding the relationship between ocular structural development and its corresponding function. The eye model is constructed based on anatomical measurements of thicknesses and indices of refraction of the various ocular media. The model then derives the gradient index distribution of the crystalline lens using a ray tracing method with a Monte Carlo optimization. Results indicate a diffraction-limited ocular behaviour, implying the visual acuity of the ground squirrel is more likely to be limited by photoreceptor density and diffraction effects, than by ocular geometry.
Aging and Age-Related Diseases of the Ocular Lens and Vitreous Body
Petrash, J. Mark
2013-01-01
Reduced quality of life and financial burden due to visual impairment and blindness begin to increase dramatically when individuals reach the age of 40. The major causes of age-related vision loss can be traced to changes to the structure and function of the lens, one of the tissues responsible for focusing light on the retina. Age-related nuclear cataracts, which are caused by aggregation and condensation of proteins, diminish vision because they impede the transmission and focusing of light on the retina. In addition to the slow-developing age-related form, cataracts often develop rapidly as a complication of ocular surgery, such as following vitrectomy or as a consequence of vitreous gel degeneration. Posterior capsular opacification, which can develop following cataract removal, is caused by proliferation and inappropriate accumulation of lens epithelial cells on the surfaces of intraocular lenses and the posterior lens capsule. Presbyopia is a loss of accommodative amplitude and reduced ability to shift focus from far to near objects. Onset of presbyopia is associated with an increase in lens hardness and reduced ability of the lens to change shape in response to ciliary muscle contraction. Avenues of promising research that seek to delay or prevent these causes of low vision are discussed in light of our current understanding of disease pathogenesis and some challenges that must be met to achieve success. PMID:24335070
Biocompatibility in the development of silicone-hydrogel lenses.
Jacob, Jean T
2013-01-01
In response to patient demands for extended contact lens wearing times, the contact lens industry has developed novel silicone-hydrogel (SiHy) lens materials that combine the enhanced oxygen permeability of silicone polymers with the water-based comfort of conventional hydrogels. In the past 12 years since the successful launch of these SiHy lenses, much has been learned about their ability to provide the biocompatibility necessary to sustain ocular health and comfort. A review of the unique physiologic requirements for a successful extended wear lens and how the first and current SiHy lenses address them is provided.
Association of Body Length with Ocular Parameters in Mice
Chakraborty, Ranjay; Park, Han na; Tan, Christopher C.; Weiss, Paul; Prunt, Megan C.; Pardue, Machelle T.
2017-01-01
Purpose To determine the association between changes in body length with ocular refraction, corneal radii, axial length, and lens thickness in two different mouse strains. Methods Body length, ocular refraction, corneal radii, axial length, and lens thickness were measured for two inbred mouse strains: 129S1/SvJ (n=7) and C57BL/6J (n=10) from 4 to 12 weeks of age. Body length, from tip of nose to base of tail was obtained using a digital camera. Biometric parameters, corneal radii and refractions were measured using spectral-domain optical coherence tomography, automated keratometry and infrared photorefraction, respectively. A mixed model ANOVA was performed to examine the changes in ocular parameters as a function of body length and strain in mice controlling for age, gender and weight over time. Results C57BL/6J mice had significantly longer body length (average body length at 10 weeks, 8.60 ± 0.06 cm) compared 129S1/SvJ mice (8.31 ± 0.05 cm) during development (p<0.001). C57BL/6J mice had significantly hyperopic refractions compared to 129S1/SvJ mice across age (mean refraction at 10 weeks, 129S1/SvJ: +0.99 ± 0.44 D versus C57BL/6J: +6.24 ± 0.38 D, p<0.001). Corneal radius of curvature, axial length and lens thickness (except 10 weeks lens thickness) were similar between the two strains throughout the measurement. In the mixed model ANOVA, changes in body length showed an independent and significant association with the changes in refraction (p=0.002) and corneal radii (p=0.016) for each mouse strain. No significant association was found between the changes in axial length (p=0.925) or lens thickness (p=0.973) as a function of body length and strain. Conclusions Changes in body length are significantly associated with the changes in ocular refraction and corneal radii in different mouse strains. Future studies are needed to determine if the association between body length and ocular refraction are related to changes in corneal curvature in mice. PMID:28005683
Will X-ray Safety Glasses Become Mandatory for Radiological Vascular Interventions?
Thomas, Rohit Philip; Grau, Mathias; Eldergash, Osama; Kowald, Tobias; Schnabel, Johannes; Szczechowicz, Marcin; Chavan, Ajay
2018-07-01
The annual permissible radiation ocular lens dose has been reduced to 20 millisieverts (mSv) in the current European directive 2013/59/Euratom. The aim of this study was to evaluate the personal radiation dose for vascular interventions with special focus on ocular lens dose. From May 2016 to October 2016, the personal radiation doses of two interventionists and four technicians were prospectively recorded during 206 vascular interventions. The position of personnel, intervention type and fluoroscopy time were recorded. Parameters evaluated were total body dose measured by film dosimeter, hand dose measured by ring thermoluminescent dosimeter (TLD) and ocular lens dose measured by TLD placed in front of the safety glasses. Linear regression analysis was used to estimate the dose at 2 and 5 years. The ocular lens dose, hand and total body dose of the two interventionists were 11/5, 56/47 and 0.6 mSv each, respectively. The estimated 5-year ocular dose was 113.08 mSv (95% CI 38.2-187.97)/40.95 (95% CI 16.9-64.7). Similarly, hand dose was 608.4 mSv (95% CI 442.78-774.38)/514.47 (95% CI 329.83-699.10) and body dose 6.07 mSv (95% CI 4.70-8.22)/5.12 (95% CI 3.65-6.59), respectively. Amongst four technicians, only the first assistant showed recordings of 0.3 mSv body dose, 2 mSv ocular lens dose and 5 mSv hand dose. The yearly ocular lens dose, particularly for interventionists dealing with complex interventions, could cross the permitted yearly limit set by the new Euratom directive. Therefore, X-ray safety glasses would become mandatory for complex radiological vascular interventions. Level III, non-randomized controlled cohort/follow-up study.
Sugita, Tadasu; Tsunekawa, Taichi; Matsuura, Toshiyuki; Takayama, Kei; Yamamoto, Kentaro; Kachi, Shu; Ito, Yasuki; Ueno, Shinji; Nonobe, Norie; Kataoka, Keiko; Suzumura, Ayana; Iwase, Takeshi; Terasaki, Hiroko
2017-01-01
Ocular trauma is one of the leading causes of visual impairment worldwide. Because of the popularity of cataract surgeries, aged individuals with ocular trauma commonly have a surgical wound in their eyes. The purpose of this study was to evaluate the visual outcome of cases that were coincident with intraocular lens (IOL) ejection in the eyes with ruptured open-globe ocular injuries. Consecutive patients with open-globe ocular injuries were first reviewed. Patients’ characteristics, corrected distance visual acuities (CDVAs) over 3 years after the trauma, causes of injuries, traumatic wound patterns, and coexistence of retinal detachment were examined. The relationships between poor CDVA and the other factors, including the complications of crystalline lens and IOL ejection, were examined. A total of 105 eyes/patients [43 eyes with rupture, 33 with penetrating, 28 with intraocular foreign body (IOFB), and 1 with perforating injuries] were included. Rupture injuries were common in aged patients and were mostly caused by falls, whereas penetrating and IOFB injuries were common in young male patients. CDVAs of the eyes with rupture injuries were significantly worse than those of the eyes with penetrating or IOFB injuries. CDVA from more than 50% of the ruptured eyes resulted in no light perception or light perception to 20/500. CDVA of the ruptured eyes complicated by crystalline lens ejection was significantly worse than that of those complicated by IOL ejection. The wounds of the ruptured eyes complicated by IOL ejection were mainly located at the superior corneoscleral limbus, whereas those of the eyes complicated by crystalline lens ejection were located at the posterior sclera. There were significant correlations between poor CDVA and retinal detachment and crystalline lens ejection. These results proposed a new trend in the ocular injuries that commonly occur in aged patients; history of cataract surgery might affect the final visual outcome after open-globe ocular injuries. PMID:28107485
Human Eye Development Is Characterized by Coordinated Expression of Fibrillin Isoforms
Hubmacher, Dirk; Reinhardt, Dieter P.; Plesec, Thomas; Schenke-Layland, Katja; Apte, Suneel S.
2014-01-01
Purpose. Mutations in human fibrillin-1 and -2, which are major constituents of tissue microfibrils, can affect multiple ocular components, including the ciliary zonule, lens, drainage apparatus, cornea, and retina. However, the expression pattern of the three human fibrillins and an integral microfibrillar component, MAGP1, during human eye development is not known. Methods. We analyzed sections from human eyes at gestational weeks (GWs) 6, 8, and 11 and at 1 and 3 years of age with antibodies specific for each human fibrillin isoform or MAGP1, using immunofluorescence microscopy. Results. During embryonic development, each fibrillin isoform was detected in vascular structures bridging the ciliary body and the developing lens, hyaloid vasculature, and retina. In addition, they were present in the developing corneal basement membranes and lens capsule. MAGP1 codistributed with the fibrillin isoforms. In contrast, the juvenile zonule was composed of fibrillin-1 microfibrils containing MAGP1, but fibrillin-2 was absent and fibrillin-3 was only sparsely detected. Conclusions. Fibrillin-1, -2, and, unique to humans, fibrillin-3 are found in various ocular structures during human embryonic eye development, whereas fibrillin-1 dominates the postnatal zonule. We speculate that vasculature spanning the ciliary body and lens, which elaborates fibrillin-2 and -3, may provide an initial scaffold for fibrillin assembly and zonule formation. PMID:25406291
Increased numbers of Demodex in contact lens wearers.
Jalbert, Isabelle; Rejab, Shazana
2015-06-01
The aim of this study was to determine if Demodex infestation is more frequent in contact lens wearers than in nonwearers. Secondary aims were to evaluate the effects of Demodex on the ocular surface (symptoms and signs) and to evaluate the ability of confocal laser scanning microscopy to detect and quantify the Demodex infestation compared with the conventional light microscopic technique. Forty Asian female participants (20 nonwearers, 20 lens wearers) with a mean (± SD) age of 27 (± 9) years were recruited. Ocular comfort scores (Ocular Surface Disease Index, Ocular Comfort Index, and Dry Eye Questionnaire), vital staining (corneal, conjunctival, and lid wiper), tear osmolarity, tear breakup time, and meibomian gland evaluation were evaluated. Demodex was detected using in vivo confocal microscopy and conventional light microscopy. The number of Demodex was higher in lens wearers than in nonwearers (7.6 [± 5.8] vs. 5.0 [± 3.1]; p = 0.02). Demodex was observed in a large majority (90%) of lens wearers and in 65% of nonwearers using confocal microscopy (p = 0.06). The detection rate was lower in both groups using conventional light microscopy (p = 0.003) where Demodex could only be confirmed in 70% and 60% of lens wearers and nonwearers, respectively. The number of Demodex tended to increase with age (ρ = 0.28, p = 0.08), but Demodex did not appear to affect ocular comfort or any clinical signs (p > 0.05). Contact lens wearers harbor Demodex as frequently as nonwearers and in higher numbers, which is best detected using in vivo confocal microscopy. The significance of these findings is uncertain because no associations were found with any symptoms and signs of dry eye disease.
Boost, Maureen V; Cho, Pauline
2005-06-01
The purpose of this study is to determine if there are changes in the ocular flora of overnight orthokeratology (ortho-k) patients, and the levels of contamination of their lenses and lens accessories, and to correlate compliance with levels of contamination. Normal ocular flora of 41 subjects was determined twice before commencing ortho-k lens wear by culture of the lower conjunctiva. Further specimens were collected on six follow-up visits after beginning lens wear, as were samples from their lenses, cases, and suction holders. A questionnaire on lens care was administered after the fifth visit. Three subjects provided conjunctival samples yielding Staphylococcus aureus on one occasion before lens wear, one being positive for this organism after beginning lens wear. Of 38 subjects yielding no growth or only normal eye flora before use, 28 remained free of ocular pathogens after beginning lens wear. Only four subjects had positive cultures on more than one occasion after lens wear. There was no significant difference in isolation levels of pathogens with lens wear (p = 0.423). Lens culture of 54% of subjects yielded no growth or normal flora only; lenses of 16 subjects yielded potential pathogens, including three subjects contaminated on more than one occasion. Lens isolates did not match the organisms transiently colonizing the eye. Lens case, the most frequently contaminated item, was associated with lens contamination (p < 0.001), the same organism being isolated from both items in 11 subjects. Lens suction holder was less frequently contaminated. Neither lens case nor suction holder contamination was associated with isolates from the eye. Reported good compliance correlated with lack of contamination in all but one subject. The most frequent breaches in the lens care protocol were failure to clean, disinfect, and replace the lens case. Ocular flora was not altered by ortho-k lens wear over an extended period, and patients remained free of infection. Contaminants identified were generally of a transient nature. Most patients had significant contamination of at least one item, most frequently the lens case. Lens case isolates were significantly associated with those from the lens. The majority of patients reporting good compliance had low or no contamination of their lenses and accessories.
The cellular and molecular mechanisms of vertebrate lens development
Cvekl, Aleš; Ashery-Padan, Ruth
2014-01-01
The ocular lens is a model system for understanding important aspects of embryonic development, such as cell specification and the spatiotemporally controlled formation of a three-dimensional structure. The lens, which is characterized by transparency, refraction and elasticity, is composed of a bulk mass of fiber cells attached to a sheet of lens epithelium. Although lens induction has been studied for over 100 years, recent findings have revealed a myriad of extracellular signaling pathways and gene regulatory networks, integrated and executed by the transcription factor Pax6, that are required for lens formation in vertebrates. This Review summarizes recent progress in the field, emphasizing the interplay between the diverse regulatory mechanisms employed to form lens progenitor and precursor cells and highlighting novel opportunities to fill gaps in our understanding of lens tissue morphogenesis. PMID:25406393
Situ, Ping; Simpson, Trefford L; Jones, Lyndon W; Fonn, Desmond
2010-12-01
To determine the effects of silicone hydrogel lens wear and lens-solution interactions on ocular surface sensitivity. Forty-eight adapted lens wearers completed the study, which comprised two phases. Phase 1 included habitual lens wear, no lens wear (7 ± 3 days), and balafilcon A lenses (PV; PureVision; Bausch & Lomb, Rochester, NY) with a hydrogen peroxide-based regimen for 2 weeks; phase 2 included wear of PV with the use of a multipurpose solution containing either polyhexamethylene-biguanide (PHMB) or Polyquad/Aldox (Alcon Laboratories, Fort Worth, TX) preservative, each for 1 week, with a 2-week washout period between solutions. Tactile and pneumatic (mechanical and chemical) stimuli were delivered, and thresholds were determined by Cochet-Bonnet (Luneau Ophthalmologie, Chartres, France) and Belmonte (Cooperative Research Centre for Eye Research and Technology, Sydney, NSW, Australia) pneumatic esthesiometers, respectively. Corneal and conjunctival thresholds and staining scores were assessed at baseline, after 2 and 8 hours of lens wear on day 1 and at the end of each wearing cycle (2 hours). In phase 1, compared to the no-lens baseline, corneal tactile thresholds increased at the 1-day, 8-hour and the 2-week visits (P < 0.05), whereas conjunctival mechanical thresholds decreased at the 1-day, 2-hour and the 2-week visits (P < 0.05). In phase 2, the chemical thresholds were lower with PHMB-preserved solution compared with the Polyquad/Aldox system at the 1-day, 2-hour and the 1-week visits (P < 0.05). Staining scores correlated inversely with conjunctival chemical thresholds (all P < 0.05). Ocular surface sensitivity changed in adapted lens wearers, when lenses were refit after a no-lens interval and during lens wear with different care regimens. The corneal staining that was observed with certain lens-solution combinations was accompanied by sensory alteration of the ocular surface-that is, higher levels of staining correlated with increased conjunctival chemical sensitivity. (ClinicalTrials.gov number, NCT00455455.).
Lievens, Christopher W; Connor, Charles G; Murphy, Heather
2003-10-01
The current study evaluates the response of the ocular surface to extended contact lens wear by comparing a new silicone hydrogel lens to an ACUVUE 2 lens. Twenty subjects with an average age of 28 years were randomly assigned to a fitting with ACUVUE 2 or PureVision lenses. Ocular surface assessment by impression cytology was performed at baseline and for the 6 months after initiation of lens wear. Although goblet cell density significantly increased with wear time, no statistically significant difference was observed between the contact lens groups. The average baseline goblet cell percentages were as follows: ACUVUE 2 group, 1.44; PureVision group, 1.11. The 6-month averages were as follows: ACUVUE 2 group, 3.16; PureVision group, 2.22. It appears that silicone hydrogel lenses may be slightly less irritating to the ocular surface than lenses not containing silicone. This could be a promising indicator for successful 30-day continuous wear.
Willcox, Mark; Sharma, Savitri; Naduvilath, Thomas J; Sankaridurg, Padmaja R; Gopinathan, Usha; Holden, Brien A
2011-03-01
To determine whether carriage of microbes on the contact lens or ocular surfaces during extended wear (EW) with soft hydroxyethyl methacrylate (HEMA)-based contact lenses predisposes the wearer to adverse events. Participants (non-contact lens wearers) were enrolled in a clinical study involving wear of HEMA-based hydrogel lenses on a six night EW basis with weekly replacement. Type and number of bacteria colonizing the lower lid margins, upper bulbar conjunctiva, and contact lenses during EW after one night, 1 week, 1 month, and thereafter every 3 months for 3.5 years were determined. The association of bacteria with adverse responses was compared between carriers (defined as having significant microbes cultured from two or more samples with 1 year) and noncarriers, and the strength of the association was estimated using multivariate logistic regression. Carriers of gram-positive bacteria on lenses (particularly coagulase negative staphylococci or Corynebacterium spp.) were approximately three and eight times more likely to develop contact lens-induced peripheral ulcers (CLPUs) and asymptomatic infiltrates (AIs), respectively. Staphylococcus aureus was most frequently isolated from lenses during CLPU. Carriers of gram-negative bacteria on lenses were five times more likely to develop contact lens-induced acute red eye (CLARE). Haemophilus influenzae was isolated most frequently from lenses during CLARE and AI events. Bacterial carriage on contact lenses during EW predisposes the wearer to the development of corneal inflammatory events including CLARE, CLPU, and AI.
Cole, Nerida; Hume, Emma B H; Vijay, Ajay K; Sankaridurg, Padmaja; Kumar, Naresh; Willcox, Mark D P
2010-01-01
One strategy to minimize bacteria-associated adverse responses such as microbial keratitis, contact lens-induced acute red eye (CLARE), and contact lens induced peripheral ulcers (CLPUs) that occur with contact lens wear is the development of an antimicrobial or antiadhesive contact lens. Cationic peptides represent a novel approach for the development of antimicrobial lenses. A novel cationic peptide, melimine, was covalently incorporated into silicone hydrogel lenses. Confirmation tests to determine the presence of peptide and anti-microbial activity were performed. Cationic lenses were then tested for their ability to prevent CLPU in the Staphylococcus aureus rabbit model and CLARE in the Pseudomonas aeruginosa guinea pig model. In the rabbit model of CLPU, melimine-coated lenses resulted in significant reductions in ocular symptom scores and in the extent of corneal infiltration (P < 0.05). Evaluation of the performance of melimine lenses in the CLARE model showed significant improvement in all ocular response parameters measured, including the percentage of eyes with corneal infiltrates, compared with those observed in the eyes fitted with the control lens (P < or = 0.05). Cationic coating of contact lenses with the peptide melimine may represent a novel method of prevention of bacterial growth on contact lenses and consequently result in reduction of the incidence and severity of adverse responses due to Gram-positive and -negative bacteria during lens wear.
Fernandes, Merle; Sharma, Savitri
2013-04-01
To report a rare case of microsporidial and polymicrobial keratitis in a patient with Sjogren's syndrome and ocular cicatricial pemphigoid. This is a descriptive case report. A 66-year-old lady diagnosed with Sjogren's syndrome (SS) and ocular cicatricial pemphigoid (OCP) presented to us with microbial keratitis after using a Boston sclera contact lens for a painful epithelial defect. After 9 days of medical treatment, she underwent therapeutic penetrating keratoplasty. 10% potassium hydroxide and calcofluor white wet mount revealed microsporidial spores. Gram positive cocci and Gram variable bacilli on Gram stain were identified as Staphylococcus epidermidis and Corynebacterium accolens in culture. Histopathological examination of the corneal tissue confirmed the presence of microsporidial spores. Microsporidal keratitis can occur in patients with severe ocular surface disease due to SS and OCP. Predisposing factors include dry eye, local and systemic immunosuppression and Boston scleral contact lens. Early surgical intervention may be needed to eradicate the infection. Copyright © 2012 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
Simulation of Blast Loading on an Ultrastructurally-based Computational Model of the Ocular Lens
2015-10-01
cells) is stressed by the passing shock wave. Traumatic cataract can result in a partially or fully clouded lens, complete dislo- cation of the lens...penetration by Intra-Ocular Foreign Bodies (IOFBs), but also shock propagation and solid-fluid interaction be- tween the lens and vitreous and aqueous...1040-8738. doi: 10.1097/ICU.0b013e3283140e98. T.Y. Wong, M.B. Seet, and C.L. Ang. Eye injuries in twentieth century warfare: A historical perspective. Survey of Ophthalmology, 41(6):433–459, MAY-JUN 1997. ISSN 0039-6257. i
Koh, Shizuka; Maeda, Naoyuki; Hamano, Takashi; Hirohara, Yoko; Mihashi, Toshifumi; Hori, Yuichi; Hosohata, Jun; Fujikado, Takashi; Tano, Yasuo
2008-03-01
To investigate whether the polymer composition of disposable soft contact lenses affects sequential changes in higher-order aberrations (HOAs). Fifteen subjects who wore disposable soft contact lenses with dryness-related symptoms and 15 non-contact lens wearers were enrolled in this study. Ocular HOAs were measured for 60 seconds in each subject wearing a disposable etafilcon A lens (conventional lens) or a disposable etafilcon A lens with polyvinyl pyrrolidone (PVP) (lens with PVP) after 1 hour of contact lens wear. During the measurement, subjects were forced to blink every 10 seconds. The aberration data were analyzed in the central 4-mm diameter up to the sixth-order Zernike polynomials. Total HOAs, the fluctuation index (FI), and the stability index (SI) of the total HOAs over time were compared between the two groups. The subjective ocular dryness also was scored. In symptomatic wearers of disposable soft contact lenses, the total HOAs, the FI, and the SI with the lens with PVP were significantly (P=0.013, P=0.014, P=0.019, respectively) lower than with the conventional lens, whereas a significant (P=0.018) difference between the two lenses was observed only in the FI in non-contact lens wearers. Subjective ocular dryness with the lens with PVP significantly decreased compared with the conventional lens in both groups. Sequential measurement of HOAs may be a useful objective method to evaluate the effect of internal lubricating agents of disposable soft contact lenses on optical quality.
Effect of Age-Related Human Lens Sutures Growth on Its Fluid Dynamics.
Wu, Ho-Ting D; Howse, Louisa A; Vaghefi, Ehsan
2017-12-01
Age-related nuclear cataract is the opacification of the clear ocular lens due to oxidative damage as we age, and is the leading cause of blindness in the world. A lack of antioxidant supply to the core of ever-growing ocular lens could contribute to the cause of this condition. In this project, a computational model was developed to study the sutural fluid inflow of the aging human lens. Three different SOLIDWORKS computational fluid dynamics models of the human lens (7 years old; 28 years old; 46 years old) were created, based on available literature data. The fluid dynamics of the lens sutures were modelled using the Stokes flow equations, combined with realistic physiological boundary conditions and embedded in COMSOL Multiphysics. The flow rate, volume, and flow rate per volume of fluid entering the aging lens were examined, and all increased over the 40 years modelled. However, while the volume of the lens grew by ∼300% and the flow rate increased by ∼400%, the flow rate per volume increased only by very moderate ∼38%. Here, sutural information from humans of 7 to 46 years of age was obtained. In this modelled age range, an increase of flow rate per volume was observed, albeit at very slow rate. We hypothesize that with even further increasing age (60+ years old), the lens volume growth would outpace its flow rate increases, which would eventually lead to malnutrition of the lens nucleus and onset of cataracts.
Mucins in contact lens wear and dry eye conditions.
Ramamoorthy, Padmapriya; Nichols, Jason J
2008-08-01
Ocular mucins are thought to play integral roles in ocular surface lubrication, anchoring of the aqueous, stabilizing the lipid components of the tear film, eliminating foreign bodies and pathogens, and with potential involvement in cell cycle mediation and apoptotic activity of ocular surface epithelia. Ocular mucins are of secreted and membrane-associated types. Secreted mucins may be of large gel-forming type or small soluble mucins (e.g., MUC5AC and MUC7). Membrane-associated mucins such as MUCs 1 and 4 are a major component of the glycocalyx. They are thought to render structural support to the microplicae and mediate epithelial cell cycle and apoptotic activity. The alterations in ocular mucins with contact lens wear are unclear. Recent work shows mucin expression may be up-regulated during the early years of contact lens wear, and with long-term lens wear, mucin expression may return to normal levels or sub-normal levels, although this is not well understood. Further, the polar nature of mucins may be associated with their affinity for contact lens surfaces making them a component of contact lens deposition. This has potential implications in the wettability and tolerability of contact lenses, and may be impacted by surface coatings, polymer characteristics, or care solutions. Conjunctival mucin gene expression and secretion may be deficient in several ocular surface disorders associated with dry eye. Deficiency and alterations in glycosylation characteristics of MUC5AC and MUC2 have been reported in both Sjögren and non-Sjögren dry eye types. Decreased binding of the membrane-associated mucin MUC16 to the conjunctival epithelium has been reported in Sjögren dry eye while MUC1 alterations have been reported in Sjögren and non-Sjögren dry eye states. In view of the mucin involvement in dry eye conditions, stimulation of mucus secretion pathways may hold promise in the pharmaceutical treatment of dry eye.
Tear exchange and contact lenses: A review
Muntz, Alex; Subbaraman, Lakshman N.; Sorbara, Luigina; Jones, Lyndon
2015-01-01
Tear exchange beneath a contact lens facilitates ongoing fluid replenishment between the ocular surface and the lens. This exchange is considerably lower during the wear of soft lenses compared with rigid lenses. As a result, the accumulation of tear film debris and metabolic by-products between the cornea and a soft contact lens increases, potentially leading to complications. Lens design innovations have been proposed, but no substantial improvement in soft lens tear exchange has been reported. Researchers have determined post-lens tear exchange using several methods, notably fluorophotometry. However, due to technological limitations, little remains known about tear hydrodynamics around the lens and, to-date, true tear exchange with contact lenses has not been shown. Further knowledge regarding tear exchange could be vital in aiding better contact lens design, with the prospect of alleviating certain adverse ocular responses. This article reviews the literature to-date on the significance, implications and measurement of tear exchange with contact lenses. PMID:25575892
Cataract formation associated with ocular toxocariasis.
Ahn, Seong Joon; Woo, Se Joon; Hyon, Joon Young; Park, Kyu Hyung
2013-06-01
To report the clinical features of cataracts in eyes with ocular toxocariasis. Department of Ophthalmology, Seoul National University Bundang Hosptal, Seongnam, South Korea. Retrospective observational case series. The clinical diagnosis of ocular toxocariasis was based on the following characteristic features: retinal granuloma with or without ocular inflammation and positive results in serum antibody enzyme-linked immunosorbent assay. Patients younger than 60 years who presented with a unilateral cataract and were diagnosed with ocular toxocariasis between January 2009 and January 2012 were included. Demographic and ocular examination data for all patients showing atypical cataract features were collected. All cataracts were documented with anterior segment photography. Seven of 83 patients (8.4%) presented with an atypical cataract in the eye with ocular toxocariasis only. The mean patient age was 49.7 years ± 8.3 (SD) (range 38 to 59 years). All patients had small, round, white lens opacities resembling retinal granulomas. The granuloma-like opacities were located primarily in the lens midperiphery and in the subcapsular level. The lens opacity migrated in 1 patient. Ocular toxocariasis can cause a cataract with distinctive clinical features. These cataracts show a granuloma-like opacity primarily in the posterior subcapsular level; the opacity can migrate. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
A comprehensive review on contact lens for ophthalmic drug delivery.
Xu, Jiawen; Xue, Yingyan; Hu, Gaoyong; Lin, Tianyu; Gou, Jingxin; Yin, Tian; He, Haibing; Zhang, Yu; Tang, Xing
2018-07-10
With the prevalence of electronic devices and an aging population, the number of people affected with eye disease is increasing year by year. In spite of a large number of eye drops on the market, most of them do not perform sufficiently, due to rapid clearance mechanisms and ocular barriers. To enhance drug delivery to the eye, a number of novel formulations for ocular diseases have been investigated over recent decades, aiming to increase drug retention and permeation while also allowing for sustained drug release over prolonged periods. The contact lens, initially used to correct visual acuity and beautify female eyes, is one such novel formulation with outstanding potential. Recently, contact lenses have been extensively used for ocular drug delivery to enhance ocular bioavailability and reduce side effects, and are particularly suitable for the treatment of chronic diseases, and thus are of interest to ophthalmic scientists. This review summarizes contact lens classification, methods of preparation, strategies for integrating drugs into lenses, in vitro and in vivo studies, and clinical applications. This review also discusses the current state of ocular drug therapy and provides an outlook for future therapeutic opportunities in the field of ocular drug delivery. Copyright © 2018 Elsevier B.V. All rights reserved.
LeBlanc, Shannon K; Taranath, Deepa; Morris, Scott; Barnett, Christopher P
2014-02-01
Colobomata are etiologically heterogeneous and may occur as an isolated defect or as a feature of a variety of single-gene disorders, chromosomal syndromes, or malformation syndromes. Although not classically associated with Marfan syndrome, colobomata have been described in several reports of Marfan syndrome, typically involving the lens and rarely involving other ocular structures. While colobomata of the lens have been described in Marfan syndrome, there are very few reports of coloboma involving other ocular structures. We report a newborn boy presenting with coloboma of the iris, lens, retina, and optic disk who was subsequently diagnosed with Marfan syndrome. Marfan syndrome is a disorder of increased TGFβ signaling, and recent work in the mouse model suggests a role for TGFβ signaling in eye development and coloboma formation, suggesting a causal association between Marfan syndrome and coloboma. Crown Copyright © 2014. Published by Mosby, Inc. All rights reserved.
Molecular Genetics of Cataract
Shiels, Alan; Hejtmancik, J. Fielding
2017-01-01
Lens opacities or cataract(s) represent a universally important cause of visual impairment and blindness. Typically, cataract is acquired with aging as a complex disorder involving environmental and genetic risk factors. Cataract may also be inherited with an early onset either in association with other ocular and/or systemic abnormalities or as an isolated lens phenotype. Here we briefly review recent advances in gene discovery for inherited and age-related forms of cataract that are providing new insights into lens development and aging. PMID:26310156
Comparative effect of lens care solutions on blink rate, ocular discomfort and visual performance.
Yang, Shun-nan; Tai, Yu-chi; Sheedy, James E; Kinoshita, Beth; Lampa, Matthew; Kern, Jami R
2012-09-01
To help maintain clear vision and ocular surface health, eye blinks occur to distribute natural tears over the ocular surface, especially the corneal surface. Contact lens wearers may suffer from poor vision and dry eye symptoms due to difficulty in lens surface wetting and reduced tear production. Sustained viewing of a computer screen reduces eye blinks and exacerbates such difficulties. The present study evaluated the wetting effect of lens care solutions (LCSs) on blink rate, dry eye symptoms, and vision performance. Sixty-five adult habitual soft contact lens wearers were recruited to adapt to different LCSs (Opti-free, ReNu, and ClearCare) in a cross-over design. Blink rate in pictorial viewing and reading (measured with an eyetracker), dry eye symptoms (measured with the Ocular Surface Disease Index questionnaire), and visual discrimination (identifying tumbling E) immediately before and after eye blinks were measured after 2 weeks of adaption to LCS. Repeated measures anova and mixed model ancova were conducted to evaluate effects of LCS on blink rate, symptom score, and discrimination accuracy. Opti-Free resulted in lower dry eye symptoms (p = 0.018) than ClearCare, and lower spontaneous blink rate (measured in picture viewing) than ClearCare (p = 0.014) and ReNu (p = 0.041). In reading, blink rate was higher for ClearCare compared to ReNu (p = 0.026) and control (p = 0.024). Visual discrimination time was longer for the control (daily disposable lens) than for Opti-Free (p = 0.007), ReNu (p = 0.009), and ClearCare (0.013) immediately before the blink. LCSs differently affected blink rate, subjective dry eye symptoms, and visual discrimination speed. Those with wetting agents led to significantly fewer eye blinks while affording better ocular comfort for contact lens wearers, compared to that without. LCSs with wetting agents also resulted in better visual performance compared to wearing daily disposable contact lenses. These presumably are because of improved tear film quality. © 2012 The College of Optometrists.
Technology needs for the development of the accommodative intraocular lens
NASA Astrophysics Data System (ADS)
Nishi, Okihiro
2010-02-01
Refilling the lens capsule while preserving capsular integrity offers the potential to restore ocular accommodation. There are two persisting problems in capsular bag refilling for possible clinical application: Leakage of the injectable material through the capsular opening and capsular opacification. Numerous attempts for solving these cardinal problems have not been proven to be clinically applicable. Recently, we developed a novel capsular bag refilling procedure using a novel accommodative intraocular lens that serves as an optic as well as a plug for sealing the capsular opening. The procedure and the results of monkey experiments will be presented.
Turhan, Semra Akkaya; Toker, Ebru
2015-01-01
To evaluate the lens edge interaction with the ocular surface with different edge designs using optical coherence tomography and to examine the effect of lens power on the lens edge interactions. Four types of silicone hydrogel lenses with different edge designs (round-, semi-round-, chisel-, and knife-edged) at six different powers (+5.0, +3.0, +1.0, -1.0, -3.0, and -5.0 diopters) were fitted to both eyes of 20 healthy volunteers. Optical coherence tomography images were taken at the corneal center and at the limbus within 15-30 minutes after insertion. The images were evaluated with respect to two parameters: conjunctival indentation exerted by the lens edge; and the tear film gaps between the posterior surface of the lens and the ocular surface. The amount of conjunctival indentation was measured with the distortion angle of the conjunctiva at the lens edge. The degree of conjunctival indentation was highest with the chisel-edged design followed by the semi-round design (P<0.0001). Knife- and round-edged lenses exerted similar levels of conjunctival indentation that was significantly lower compared to chisel-edged lens (P<0.001). For each one of the tested lens edge designs, no significant difference was observed in the conjunctival indentation with respect to lens power. The chisel-edged lens produced the highest amount of conjunctival indentation for each one of the six lens powers (P<0.0001). Post-lens tear film gaps at the limbus were observed at most in the round-edge design (P=0.001). The fitting properties of contact lenses may be influenced by their edge design but not by their lens power.
Turhan, Semra Akkaya; Toker, Ebru
2015-01-01
Purpose To evaluate the lens edge interaction with the ocular surface with different edge designs using optical coherence tomography and to examine the effect of lens power on the lens edge interactions. Methods Four types of silicone hydrogel lenses with different edge designs (round-, semi-round-, chisel-, and knife-edged) at six different powers (+5.0, +3.0, +1.0, −1.0, −3.0, and −5.0 diopters) were fitted to both eyes of 20 healthy volunteers. Optical coherence tomography images were taken at the corneal center and at the limbus within 15–30 minutes after insertion. The images were evaluated with respect to two parameters: conjunctival indentation exerted by the lens edge; and the tear film gaps between the posterior surface of the lens and the ocular surface. The amount of conjunctival indentation was measured with the distortion angle of the conjunctiva at the lens edge. Results The degree of conjunctival indentation was highest with the chisel-edged design followed by the semi-round design (P<0.0001). Knife- and round-edged lenses exerted similar levels of conjunctival indentation that was significantly lower compared to chisel-edged lens (P<0.001). For each one of the tested lens edge designs, no significant difference was observed in the conjunctival indentation with respect to lens power. The chisel-edged lens produced the highest amount of conjunctival indentation for each one of the six lens powers (P<0.0001). Post-lens tear film gaps at the limbus were observed at most in the round-edge design (P=0.001). Conclusion The fitting properties of contact lenses may be influenced by their edge design but not by their lens power. PMID:26045658
The safety and efficacy of contact lens wear in the industrial and chemical workplace.
Tyhurst, Keith; McNett, Ryan; Bennett, Edward
2007-11-01
The use and safety of contact lenses in the industrial and chemical workplace has often been questioned since the 1960s because of many unconfirmed reports of ocular injury resulting from contact lens wear. Because of these urban legends, contact lens wear has been banned or wearers have been required to wear additional personal protective equipment (PPE) not required of non-contact lens wearers. Literature review via Medline and Google search. Research has shown that contact lenses typically provide protective benefits that decrease the severity of ocular injury and improve worker performance. While contact lens wear contraindications do exist, in most cases, and with proper precautions, contact lens wear is still possible. Industrial and chemical companies need to establish written contact lens use policies based on current studies that have shown the safety of workplace contact lens wear when combined with the same PPE required of non-contact lens wearers. Practitioners need to discuss, with their contact lens patients, the additional responsibilities required to maintain proper lens hygiene and proper PPE in the workplace.
Dutta, Debarun; Zhao, Timothy; Cheah, Kai Bing; Holmlund, Larke; Willcox, Mark D P
2017-06-01
To determine the antimicrobial activity of the melimine derived peptide Mel4 against Delftia, Stenotrophomonas, Elizabethkingia, Burkholderia and to investigate biocompatibility of Mel4 as an antimicrobial coating on contact lenses in animals and humans. In vitro antimicrobial activity of Mel4 was determined against the four Gram negative bacteria by investigating growth curves for 24h followed by viable counts to determine the minimum inhibitory concentration (MIC). Contact lenses were coated by covalently binding Mel4, characterized by amino acid analysis, and were investigated for changes in lens parameters. Safety of Mel-4 coated lenses were determined in a rabbit model of daily contralateral wear. A prospective, randomised, double-masked, contralateral, 1week daily wear human clinical trial was used to evaluate subjective responses and ocular physiology. Mel4 was active against all the bacteria tested (MIC 50 ranged from 31-1000μgml -1 ) and produced an antimicrobial surface on contact lenses. Mel4-coating resulted hydrophilic surface without any significant change in contact lens parameters, and showed no signs of cytotoxicity or ocular irritation during rabbit wear. During human clinical trial, there were no differences between Mel4 coated and uncoated contact lenses in lens performance indicators and ocular signs such as corneal fluorescein staining. Mel4 and control uncoated lenses had no differences in ocular symptoms during lens wear. Mel4 has achieved antimicrobial activity against variety of Gram negative bacteria that are often resistant to the action of cationic peptides and have been implicated in contact lens related adverse events. Mel4-coated contact lenses were safe to wear. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
Szczotka-Flynn, Loretta B; Pearlman, Eric; Ghannoum, Mahmoud
2010-03-01
A contact lens (CL) can act as a vector for microorganisms to adhere to and transfer to the ocular surface. Commensal microorganisms that uneventfully cohabitate on lid margins and conjunctivae and potential pathogens that are found transiently on the ocular surface can inoculate CLs in vivo. In the presence of reduced tissue resistance, these resident microorganisms or transient pathogens can invade and colonize the cornea or conjunctiva to produce inflammation or infection. The literature was reviewed and used to summarize the findings over the last 30 years on the identification, enumeration, and classification of microorganisms adherent to CLs and their accessories during the course of normal wear and to hypothesize the role that these microorganisms play in CL infection and inflammation. Lens handling greatly increases the incidence of lens contamination, and the ocular surface has a tremendous ability to destroy organisms. However, even when removed aseptically from the eye, more than half of lenses are found to harbor microorganisms, almost exclusively bacteria. Coagulase-negative Staphylococci are most commonly cultured from worn lenses; however, approximately 10% of lenses harbor Gram-negative and highly pathogenic species, even in asymptomatic subjects. In storage cases, the incidence of positive microbial bioburden is also typically greater than 50%. All types of care solutions can become contaminated, including up to 30% of preserved products. The process of CL-related microbial keratitis and inflammation is thought to be preceded by the presence or transfer or both of microorganisms from the lens to the ocular surface. Thus, this detailed understanding of lens-related bioburden is important in the understanding of factors associated with infectious and inflammatory complications. Promising mechanisms to prevent bacterial colonization on lenses and lens cases are forthcoming, which may decrease the incidence of microbially driven CL complications.
Tear exchange and contact lenses: a review.
Muntz, Alex; Subbaraman, Lakshman N; Sorbara, Luigina; Jones, Lyndon
2015-01-01
Tear exchange beneath a contact lens facilitates ongoing fluid replenishment between the ocular surface and the lens. This exchange is considerably lower during the wear of soft lenses compared with rigid lenses. As a result, the accumulation of tear film debris and metabolic by-products between the cornea and a soft contact lens increases, potentially leading to complications. Lens design innovations have been proposed, but no substantial improvement in soft lens tear exchange has been reported. Researchers have determined post-lens tear exchange using several methods, notably fluorophotometry. However, due to technological limitations, little remains known about tear hydrodynamics around the lens and, to-date, true tear exchange with contact lenses has not been shown. Further knowledge regarding tear exchange could be vital in aiding better contact lens design, with the prospect of alleviating certain adverse ocular responses. This article reviews the literature to-date on the significance, implications and measurement of tear exchange with contact lenses. Copyright © 2014 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.
The biometric study in different stages of primary angle-closure glaucoma
Chen, Y-Y; Chen, Y-Y; Sheu, S-J; Chou, P
2013-01-01
Purpose This study compared the general and ocular biometric characteristics of normal, primary angle closure (PAC), and primary angle-closure glaucoma (PACG) patients to better understand the possible relationship between differences in ocular parameters that might predict risk for PACG in PAC patients. Methods One hundred normal, 90 PAC, and 90 PACG eyes were retrospectively reviewed. General characteristics such as age, gender, body height, body weight, blood pressure, pulse, systemic diseases, and education level were recorded. Ocular findings included visual acuity, intraocular pressure, refraction, cup to disc ratio, and ocular biometry. Ocular biometry was obtained by A-scan ultrasonography (Digital A/B scan 5500; Sonomed Inc., Lake Success, NY, USA). The parameters recorded were anterior chamber depth (ACD), lens thickness (LT), axial length (AXL), lens/axial length factor (LAF), and relative lens position (RLP). Results Although the controls, PAC group, and PACG group were found to be significantly different in age (62.7±9.8; 65.3±7.5; and 66.0±7.4, respectively), there were no gender differences. With regard to ocular parameters, the ACD tended to decrease and the LT and LAF tended to increase from normal to PAC to PACG. The eyes of the PACG group had significantly shallower ACD (P<0.001) and thicker lens (P<0.001) than those of the PAC group. While PAC had similar lens position to the control group, PACG had more anteriorly positioned lens than the PAC group (P<0.001). Logistic regression analysis found a significant association between a decrease in ACD and increased risk of PACG (odds ratio (OR)=3.59 for 0.2 mm decrease in ACD) as well as a significant association between an increase in LT and increased risk of PACG (OR=1.30). Conclusions In addition to LT, a shallower ACD owing to a change in RLP may have a role in the progression from PAC to PACG. Owing to the differences of certain biometric characteristics between PAC and PACG, A-scan ultrasonography might potentially be used for the early detection of PACG in PAC eyes. PMID:23788204
Novel Approaches in Formulation and Drug Delivery using Contact Lenses
Singh, Kishan; Nair, Anroop B; Kumar, Ashok; Kumria, Rachna
2011-01-01
The success of ocular delivery relies on the potential to enhance the drug bioavailability by controlled and extended release of drug on the eye surface. Several new approaches have been attempted to augment the competence and diminish the intrinsic side effects of existing ocular drug delivery systems. In this contest, progress has been made to develop drug-eluting contact lens using different techniques, which have the potential to control and sustain the delivery of drug. Further, the availability of novel polymers have facilitated and promoted the utility of contact lenses in ocular drug delivery. Several research groups have already explored the feasibility and potential of contact lens using conventional drugs for the treatment of periocular and intraocular diseases. Contact lenses formulated using modern technology exhibits high loading, controlled drug release, apposite thickness, water content, superior mechanical and optical properties as compared to commercial lenses. In general, this review discus various factors and approaches designed and explored for the successful delivery of ophthalmic drugs using contact lenses as drug delivery device PMID:24826007
NASA Astrophysics Data System (ADS)
Chen, Yi-Chun; Jiang, Chong-Jhih; Yang, Tsung-Hsun; Sun, Ching-Cherng
2012-07-01
A biometry-based human eye model was developed by using the empirical anatomic and optical data of ocular parameters. The gradient refractive index of the crystalline lens was modeled by concentric conicoid isoindical surfaces and was adaptive to accommodation and age. The chromatic dispersion of ocular media was described by Cauchy equations. The intraocular scattering model was composed of volumetric Mie scattering in the cornea and the crystalline lens, and a diffusive-surface model at the retina fundus. The retina was regarded as a Lambertian surface and was assigned its corresponding reflectance at each wavelength. The optical performance of the eye model was evaluated in CodeV and ASAP and presented by the modulation transfer functions at single and multiple wavelengths. The chromatic optical powers obtained from this model resembled that of the average physiological eyes. The scattering property was assessed by means of glare veiling luminance and compared with the CIE general disability glare equation. By replacing the transparent lens with a cataractous lens, the disability glare curve of cataracts was generated to compare with the normal disability glare curve. This model has high potential for investigating visual performance in ordinary lighting and display conditions and under the influence of glare sources.
Nonhuman Primate Ocular Biometry
Augusteyn, Robert C.; Maceo Heilman, Bianca; Ho, Arthur; Parel, Jean-Marie
2016-01-01
Purpose To examine ocular growth in nonhuman primates (NHPs) from measurements on ex vivo eyes. Methods We obtained NHP eyes from animals that had been killed as part of other studies or because of health-related issues. Digital calipers were used to measure the horizontal, vertical, and anteroposterior globe diameters as well as corneal horizontal and vertical diameters of excised globes from 98 hamadryas baboons, 551 cynomolgus monkeys, and 112 rhesus monkeys, at ages ranging from 23 to 360 months. Isolated lens sagittal thickness and equatorial diameter were measured by shadowphotogrammetry. Wet and fixed dry weights were obtained for lenses. Results Nonhuman primate globe growth continues throughout life, slowing toward an asymptotic maximum. The final globe size scales with negative allometry to adult body size. Corneal growth ceases at around 20 months. Lens diameter increases but thickness decreases with increasing age. Nonhuman primate lens wet and dry weight accumulation is monophasic, continuing throughout life toward asymptotic maxima. The dry/wet weight ratio reaches a maximum of 0.33. Conclusions Nonhuman primate ocular globe and lens growth differ in several respects from those in humans. Although age-related losses of lens power and accommodative amplitude are similar, lens growth and properties are different indicating care should be taken in extrapolating NHP observations to the study of human accommodation. PMID:26780314
Ocular discomfort responses after short periods of contact lens wear.
Papas, Eric; Tilia, Daniel; McNally, John; de la Jara, Percy Lazon
2015-06-01
To investigate if contact lens-related discomfort is a function of the time of day at which lenses are worn. This was a randomized, crossover, open-label clinical trial where subjective responses, with and without contact lenses, were assessed every 2 hours during five stages (A to E). Each stage began at the time when subjects would normally have inserted their contact lenses (T0). During stage A, no lenses were worn, whereas in stage B, lenses were worn continuously for 12 hours. In stages C to E, lenses were worn for only 4 hours. Contact lenses were inserted at T0 for stage C, but for stages D and E, lenses were not inserted until T0 + 4 and T0 + 8 hours, respectively. Mixed linear models were used for statistical analysis. In the absence of contact lenses, ocular comfort and dryness remained reasonably constant throughout the observation period. Ocular comfort and dryness decreased during 12 hours of continuous lens wear and became significantly worse from the 8-hour time onward compared with insertion (p < 0.023). There were no significant differences in terms of ocular comfort and dryness between any of the 4-hour lens wear stages (p < 0.82). During each 4-hour stage, both comfort and dryness behaved in a similar fashion (p > 0.05) to the first 4 hours of continuous contact lens wear. Comparing the scores of each of these stages with the no-lens response at the corresponding time showed no significant differences for comfort (p > 0.23) or dryness (p > 0.37). Short periods of wear can be experienced at any time of day without significant change in ocular discomfort and dryness. This suggests that subjective responses at the end of the day are determined by the length of time lenses are in contact with the eye, rather than the time of day at which lenses are worn.
Predicting success with silicone-hydrogel contact lenses in new wearers.
Best, Nigel; Drury, Laura; Wolffsohn, James S
2013-10-01
to evaluate changes in tear metrics and ocular signs induced by six months of silicone-hydrogel contact lens wear and the difference in baseline characteristics between those who successfully continued in contact lens wear compared to those that did not. Non-invasive Keratograph, Tearscope and fluorescein tear break-up times (TBUTs), tear meniscus height, bulbar and limbal hyperaemia, lid-parallel conjunctival folds (LIPCOF), phenol red thread, fluorescein and lissamine-green staining, and lid wiper epitheliopathy were measured on 60 new contact lens wearers fitted with monthly silicone-hydrogels (average age 36±14 years, 40 females). Symptoms were evaluated by the Ocular Surface Disease Index (OSDI). After six months full time contact lens wear the above metrics were re-measured on those patients still in contact lens wear (n=33). The initial measurements were also compared between the group still wearing lenses after six months and those who had ceased lens wear (n=27). There were significant changes in tear meniscus height (p=0.031), bulbar hyperaemia (p=0.011), fluorescein TBUT (p=0.027), corneal (p=0.007) and conjunctival (p=0.009) staining, LIPCOF (p=0.011) and lid wiper epitheliopathy (p=0.002) after six months of silicone-hydrogel wear. Successful wearers had a higher non-invasive (17.0±8.2s vs 12.0±5.6s; p=0.001) and fluorescein (10.7±6.4s vs 7.5±4.7s; p=0.001) TBUT than drop-outs, although OSDI (cut-off 4.2) was also a strong predictor of success. Silicone-hydrogel lenses induced significant changes in the tear film and ocular surface as well as lid margin staining. Wettability of the ocular surface is the main factor affecting contact lens drop-out. Copyright © 2013 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
Inner layer-embedded contact lenses for pH-triggered controlled ocular drug delivery.
Zhu, Qiang; Liu, Chang; Sun, Zheng; Zhang, Xiaofei; Liang, Ning; Mao, Shirui
2018-07-01
Contact lenses (CLs) are ideally suited for controlled ocular drug delivery, but are limited by short release duration, poor storage stability and low drug loading. In this study, we present a novel inner layer-embedded contact lens capable of pH-triggered extended ocular drug delivery with good storage stability. Blend film of ethyl cellulose and Eudragit S100 was used as the inner layer, while pHEMA hydrogel was used as outer layer to fabricate inner layer-embedded contact lens. Using diclofenac sodium(DS) as a drug model, influence of polymer ratio in the blend film, EC viscosity, drug/polymer ratio, inner layer thickness and outlayer thickness of pHEMA hydrogel on drug release behavior was studied and optimized for daily use. The pH-triggered drug eluting pattern enables the inner layer-embedded contact lens being stored in phosphate buffer solution pH 6.8 with ignorable drug loss and negligible changes in drug release pattern. In vivo pharmacokinetic study in rabbits showed sustained drug release for over 24 h in tear fluid, indicating significant improvement in drug corneal residence time. A level A IVIVC was established between in vitro drug release and in vivo drug concentration in tear fluid. In conclusion, this inner layer embedded contact lens design could be used as a platform for extended ocular drug delivery with translational potential for both anterior and posterior ocular diseases therapy. Copyright © 2018 Elsevier B.V. All rights reserved.
Riddell, Nina; Faou, Pierre; Murphy, Melanie; Giummarra, Loretta; Downs, Rachael A.; Rajapaksha, Harinda
2017-01-01
Purpose Microarray and RNA sequencing studies in the chick model of early optically induced refractive error have implicated thousands of genes, many of which have also been linked to ocular pathologies in humans, including age-related macular degeneration (AMD), choroidal neovascularization, glaucoma, and cataract. These findings highlight the potential relevance of the chick model to understanding both refractive error development and the progression to secondary pathological complications. The present study aimed to determine whether proteomic responses to early optical defocus in the chick share similarities with these transcriptome-level changes, particularly in terms of dysregulation of pathology-related molecular processes. Methods Chicks were assigned to a lens condition (monocular +10 D [diopters] to induce hyperopia, −10 D to induce myopia, or no lens) on post-hatch day 5. Biometric measures were collected following a further 6 h and 48 h of rearing. The retina/RPE was then removed and prepared for liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) on an LTQ-Orbitrap Elite. Raw data were processed using MaxQuant, and differentially abundant proteins were identified using moderated t tests (fold change ≥1.5, Benjamini-Hochberg adjusted p<0.05). These differentially abundant proteins were compared with the genes and proteins implicated in previous exploratory transcriptome and proteomic studies of refractive error, as well as the genes and proteins linked to the ocular pathologies listed above for which myopia or hyperopia are risk factors. Finally, gene set enrichment analysis (GSEA) was used to assess whether gene sets from the Human Phenotype Ontology database were enriched in the lens groups relative to the no lens groups, and at the top or bottom of the protein data ranked by Spearman’s correlation with refraction at 6 and 48 h. Results Refractive errors of −2.63 D ± 0.31 D (mean ± standard error, SE) and 3.90 D ± 0.37 D were evident in the negative and positive lens groups, respectively, at 6 h. By 48 h, refractive compensation to both lens types was almost complete (negative lens −9.70 D ± 0.41 D, positive lens 7.70 D ± 0.44 D). More than 140 differentially abundant proteins were identified in each lens group relative to the no lens controls at both time points. No proteins were differentially abundant between the negative and positive lens groups at 6 h, and 13 were differentially abundant at 48 h. As there was substantial overlap in the proteins implicated across the six comparisons, a total of 390 differentially abundant proteins were identified. Sixty-five of these 390 proteins had previously been implicated in transcriptome studies of refractive error animal models, and 42 had previously been associated with AMD, choroidal neovascularization, glaucoma, and/or cataract in humans. The overlap of differentially abundant proteins with AMD-associated genes and proteins was statistically significant for all conditions (Benjamini-Hochberg adjusted p<0.05), with over-representation analysis implicating ontologies related to oxidative stress, cholesterol homeostasis, and melanin biosynthesis. GSEA identified significant enrichment of genes associated with abnormal electroretinogram, photophobia, and nyctalopia phenotypes in the proteins negatively correlated with ocular refraction across the lens groups at 6 h. The implicated proteins were primarily linked to photoreceptor dystrophies and mitochondrial disorders in humans. Conclusions Optical defocus in the chicks induces rapid changes in the abundance of many proteins in the retina/RPE that have previously been linked to inherited and age-related ocular pathologies in humans. Similar changes have been identified in a meta-analysis of chick refractive error transcriptome studies, highlighting the chick as a model for the study of optically induced stress with possible relevance to understanding the development of a range of pathological states in humans. PMID:29259393
Papas, Eric B; Sweeney, Deborah F
2016-10-01
When anoxia (0% oxygen) is created within a gas-tight goggle, ocular physiological responses, including corneal swelling, limbal hyperaemia and pH change, are known to vary, depending on the presence or absence of a low, oxygen transmissibility contact lens. A new theory is proposed to account for this discrepancy based on the concept of lid derived oxygen, whereby oxygen originating from the vascular plexus of the palpebral conjunctiva supplements that available to the ocular surface in an open, normally blinking eye, even when the surrounding gaseous atmosphere is anoxic. The effect of a lid derived contribution to corneal oxygenation was assessed by using existing experimental data to model open-eye, corneal swelling behavior as a function of atmospheric oxygen content, both with and without the presence of a contact lens. These models predict that under atmospheric anoxia, contact lens wear results in 13.2% corneal swelling compared with only 5.4% when the lens was absent. Lid derived oxygen acts to provide the ocular surface in the non-contact lens wearing, normally blinking, open-eye with up to 4.7% equivalent oxygen concentration, even within the anoxic environment of a nitrogen filled goggle. Correcting for lid derived oxygen eliminates previously observed discrepancies in corneal swelling behavior and harmonizes the models for the contact lens wearing and gas-goggle cases. On this basis it is proposed that true anoxia at the ocular surface cannot be achieved by atmospheric manipulation (i.e. a gas-goggle) alone but requires an additional presence, e.g. a low, oxygen transmissibility contact lens, to prevent access to oxygen from the eyelids. Data from previously conducted experiments in which the gas-goggle paradigm was used, may have been founded on underestimates of the real oxygen concentration acting on the ocular surface at the time and if so, will require re-interpretation. Future work in this area should consider if a correction for lid derived oxygen is necessary. Copyright © 2016 Elsevier Ltd. All rights reserved.
Sankaridurg, P R; Willcox, M D; Sharma, S; Gopinathan, U; Janakiraman, D; Hickson, S; Vuppala, N; Sweeney, D F; Rao, G N; Holden, B A
1996-01-01
Ten episodes of adverse responses to contact lens wear, including contact lens-induced acute red eye (CLARE), in which Haemophilus influenzae was isolated from contact lenses and/or from one of the external ocular sites at the time of the event, are described. All episodes occurred in patients wearing disposable hydrogel lenses on a 6-night extended-wear schedule. Two of the patients had recurrent episodes. H. influenzae was usually isolated in large numbers, and other bacteria or fungi colonizing the contact lens or the external ocular surface were usually present in low numbers. Those patients who were colonized with H. influenzae were more than 100 times as likely to have had a CLARE or infiltrative response than those subjects who were not colonized with this bacterium. H. influenzae colonization of the contact lens and eye may be subsequent to colonization of the nasopharynx because four of the seven patients presented with fever at the time of the event, with concurrent upper respiratory tract infection. Contact lens wearers should be made aware of the potential risk of CLARE associated with the wearing of contact lenses for extended periods during and subsequent to upper respiratory tract infection. PMID:8880493
Korogiannaki, Myrto; Zhang, Jianfeng; Sheardown, Heather
2017-10-01
Discontinuation of contact lens wear as a result of ocular dryness and discomfort is extremely common; as many as 26% of contact lens wearers discontinue use within the first year. While patients are generally satisfied with conventional hydrogel lenses, improving on-eye comfort continues to remain a goal. Surface modification with a biomimetic, ocular friendly hydrophilic layer of a wetting agent is hypothesized to improve the interfacial interactions of the contact lens with the ocular surface. In this work, the synthesis and characterization of poly(2-hydroxyethyl methacrylate) surfaces grafted with a hydrophilic layer of hyaluronic acid are described. The immobilization reaction involved the covalent attachment of thiolated hyaluronic acid (20 kDa) on acrylated poly(2-hydroxyethyl methacrylate) via nucleophile-initiated Michael addition thiol-ene "click" chemistry. The surface chemistry of the modified surfaces was analyzed by Fourier transform infrared spectroscopy-attenuated total reflectance and X-ray photoelectron spectroscopy. The appearance of N (1s) and S (2p) peaks on the low resolution X-ray photoelectron spectroscopy spectra confirmed successful immobilization of hyaluronic acid. Grafting hyaluronic acid to the poly(2-hydroxyethyl methacrylate) surfaces decreased the contact angle, the dehydration rate, and the amount of nonspecific sorption of lysozyme and albumin in comparison to pristine hydrogel materials, suggesting the development of more wettable surfaces with improved water-retentive and antifouling properties, while maintaining optical transparency (>92%). In vitro testing also showed excellent viability of human corneal epithelial cells with the hyaluronic acid-grafted poly(2-hydroxyethyl methacrylate) surfaces. Hence, surface modification with hyaluronic acid via thiol-ene "click" chemistry could be useful in improving contact lens surface properties, potentially alleviating symptoms of contact lens related dryness and discomfort during wear.
Contact lens management of irregular corneas after traumatic aphakia: A pediatric case series.
Aung, Yin-Yin; McLeod, Andrew
2015-10-01
Pediatric patients account for 35% of all cases that present after ocular trauma and 20.9% of those result in a ruptured globe. When repairing the globe, the removal of the natural lens results in a significant change in refractive error and loss of accommodation. In addition, the eye can have scarring, irregular astigmatism, and changes to the ocular surface. Treatment and vision rehabilitation should be aggressive and done quickly to prevent amblyopia. Advanced lens designs are often needed to treat both the irregular ocular surface and the aphakia. Treatment options are often confounded with the usual issues of contact lens compliance, intolerance, and complications. This case series follows three aphakic pediatric patients through the contact lens fitting process after sustaining a ruptured globe that left them aphakic with residual irregular astigmatism and corneal scarring. Patient 1 is a 3-year-old Hispanic male fit with a bitoric gas permeable contact lens with irregular astigmatism and an elevated central corneal scarring. Patient 2 is a 12-year-old Caucasian male with minimal residual astigmatism fit in a multifocal soft contact lens. Patient 3 is an 8-year-old African American male fit with a hybrid contact lens that was needed to vault the irregular astigmatism and central corneal scarring. Treating patients with irregular corneas or aphakia can be challenging in their own right, but in combination are some of the most advanced specialty contact lens fittings. This case series followed three pediatric patients through the fitting process and demonstrated the options and challenges when fitting this unique patient population. Copyright © 2015 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
A Stochastic Model of Eye Lens Growth
Šikić, Hrvoje; Shi, Yanrong; Lubura, Snježana; Bassnett, Steven
2015-01-01
The size and shape of the ocular lens must be controlled with precision if light is to be focused sharply on the retina. The lifelong growth of the lens depends on the production of cells in the anterior epithelium. At the lens equator, epithelial cells differentiate into fiber cells, which are added to the surface of the existing fiber cell mass, increasing its volume and area. We developed a stochastic model relating the rates of cell proliferation and death in various regions of the lens epithelium to deposition of fiber cells and lens growth. Epithelial population dynamics were modeled as a branching process with emigration and immigration between various proliferative zones. Numerical simulations were in agreement with empirical measurements and demonstrated that, operating within the strict confines of lens geometry, a stochastic growth engine can produce the smooth and precise growth necessary for lens function. PMID:25816743
Kenney, Kristin S; Fanciullo, Lisa M
2005-07-01
Although air bags are placed in automobiles to act as safety devices, they have been shown to carry a risk of injury themselves. Ocular injury, in particular, can often be a direct consequence of air bag deployment. A case of ocular air bag injury is presented. A discussion and review of the current literature on this issue follows. A 63-year-old man was transferred to our clinic after sustaining injuries related to a motor vehicle accident, during which the automobile's air bag was deployed. Initial examination revealed many signs of blunt ocular trauma of the O.D., including iridodialysis, dislocated lens with traumatic cataract, and traumatic/inflammatory glaucoma. Initial B-scan showed an attached retina O.D. One month later, the patient underwent an attempted pars plana vitrectomy with lensectomy, iris repair, and insertion of an anterior chamber intraocular lens. Complications arose during the procedure, and a total retinal detachment developed. Resultant acuity is no light perception O.D. Although ocular morbidity can be a direct consequence of air bag deployment, most eye injuries are minimal, and seem to be outweighed by the benefits of air bags. Drivers, as well as passengers, can minimize associated injuries by adhering to specific safety guidelines. This, as well as continual modification and improvement in air bag design, will maximize the safety of air bags and decrease the incidence of vision-threatening ocular injury caused by air bag deployment.
Aquaporins in the eye: Expression, function, and roles in ocular disease☆
Schey, Kevin L.; Wang, Zhen; Wenke, Jamie L.; Qi, Ying
2015-01-01
Background All thirteen known mammalian aquaporins have been detected in the eye. Moreover, aquaporins have been identified as playing essential roles in ocular functions ranging from maintenance of lens and corneal transparency to production of aqueous humor to maintenance of cellular homeostasis and regulation of signal transduction in the retina. Scope of review This review summarizes the expression and known functions of ocular aquaporins and discusses their known and potential roles in ocular diseases. Major conclusions Aquaporins play essential roles in all ocular tissues. Remarkably, not all aquaporin function as a water permeable channel and the functions of many aquaporins in ocular tissues remain unknown. Given their vital roles in maintaining ocular function and their roles in disease, aquaporins represent potential targets for future therapeutic development. General significance Since aquaporins play key roles in ocular physiology, an understanding of these functions is important to improving ocular health and treating diseases of the eye. It is likely that future therapies for ocular diseases will rely on modulation of aquaporin expression and/or function. This article is part of a Special Issue entitled Aquaporins. PMID:24184915
Stapleton, Fiona; Marfurt, Carl; Golebiowski, Blanka; Rosenblatt, Mark; Bereiter, David; Begley, Carolyn; Dartt, Darlene; Gallar, Juana; Belmonte, Carlos; Hamrah, Pedram; Willcox, Mark
2013-01-01
This report characterizes the neurobiology of the ocular surface and highlights relevant mechanisms that may underpin contact lens–related discomfort. While there is limited evidence for the mechanisms involved in contact lens–related discomfort, neurobiological mechanisms in dry eye disease, the inflammatory pathway, the effect of hyperosmolarity on ocular surface nociceptors, and subsequent sensory processing of ocular pain and discomfort have been at least partly elucidated and are presented herein to provide insight in this new arena. The stimulus to the ocular surface from a contact lens is likely to be complex and multifactorial, including components of osmolarity, solution effects, desiccation, thermal effects, inflammation, friction, and mechanical stimulation. Sensory input will arise from stimulation of the lid margin, palpebral and bulbar conjunctiva, and the cornea. PMID:24058137
Ocular drug delivery systems: An overview
Patel, Ashaben; Cholkar, Kishore; Agrahari, Vibhuti; Mitra, Ashim K
2014-01-01
The major challenge faced by today’s pharmacologist and formulation scientist is ocular drug delivery. Topical eye drop is the most convenient and patient compliant route of drug administration, especially for the treatment of anterior segment diseases. Delivery of drugs to the targeted ocular tissues is restricted by various precorneal, dynamic and static ocular barriers. Also, therapeutic drug levels are not maintained for longer duration in target tissues. In the past two decades, ocular drug delivery research acceleratedly advanced towards developing a novel, safe and patient compliant formulation and drug delivery devices/techniques, which may surpass these barriers and maintain drug levels in tissues. Anterior segment drug delivery advances are witnessed by modulation of conventional topical solutions with permeation and viscosity enhancers. Also, it includes development of conventional topical formulations such as suspensions, emulsions and ointments. Various nanoformulations have also been introduced for anterior segment ocular drug delivery. On the other hand, for posterior ocular delivery, research has been immensely focused towards development of drug releasing devices and nanoformulations for treating chronic vitreoretinal diseases. These novel devices and/or formulations may help to surpass ocular barriers and associated side effects with conventional topical drops. Also, these novel devices and/or formulations are easy to formulate, no/negligibly irritating, possess high precorneal residence time, sustain the drug release, and enhance ocular bioavailability of therapeutics. An update of current research advancement in ocular drug delivery necessitates and helps drug delivery scientists to modulate their think process and develop novel and safe drug delivery strategies. Current review intends to summarize the existing conventional formulations for ocular delivery and their advancements followed by current nanotechnology based formulation developments. Also, recent developments with other ocular drug delivery strategies employing in situ gels, implants, contact lens and microneedles have been discussed. PMID:25590022
Ocular drug delivery systems: An overview.
Patel, Ashaben; Cholkar, Kishore; Agrahari, Vibhuti; Mitra, Ashim K
The major challenge faced by today's pharmacologist and formulation scientist is ocular drug delivery. Topical eye drop is the most convenient and patient compliant route of drug administration, especially for the treatment of anterior segment diseases. Delivery of drugs to the targeted ocular tissues is restricted by various precorneal, dynamic and static ocular barriers. Also, therapeutic drug levels are not maintained for longer duration in target tissues. In the past two decades, ocular drug delivery research acceleratedly advanced towards developing a novel, safe and patient compliant formulation and drug delivery devices/techniques, which may surpass these barriers and maintain drug levels in tissues. Anterior segment drug delivery advances are witnessed by modulation of conventional topical solutions with permeation and viscosity enhancers. Also, it includes development of conventional topical formulations such as suspensions, emulsions and ointments. Various nanoformulations have also been introduced for anterior segment ocular drug delivery. On the other hand, for posterior ocular delivery, research has been immensely focused towards development of drug releasing devices and nanoformulations for treating chronic vitreoretinal diseases. These novel devices and/or formulations may help to surpass ocular barriers and associated side effects with conventional topical drops. Also, these novel devices and/or formulations are easy to formulate, no/negligibly irritating, possess high precorneal residence time, sustain the drug release, and enhance ocular bioavailability of therapeutics. An update of current research advancement in ocular drug delivery necessitates and helps drug delivery scientists to modulate their think process and develop novel and safe drug delivery strategies. Current review intends to summarize the existing conventional formulations for ocular delivery and their advancements followed by current nanotechnology based formulation developments. Also, recent developments with other ocular drug delivery strategies employing in situ gels, implants, contact lens and microneedles have been discussed.
Changes to the ocular biota with time in extended- and daily-wear disposable contact lens use.
Stapleton, F; Willcox, M D; Fleming, C M; Hickson, S; Sweeney, D F; Holden, B A
1995-11-01
Gram-negative bacteria may play a role in the etiology of certain soft contact lens (SCL)-related diseases. Contact lens (CL) wear may modify the normal ocular biota, providing a more favorable environment for potential pathogens. This study reports temporal changes in ocular biota in daily-wear (DW) and extended-wear (EW) disposable SCL use in experienced and neophyte wearers. Lid margin and bulbar conjunctival biota were sampled prior to CL fitting in 26 previous DW SCL users, 18 previous EW SCL users, and 26 neophytes. Wearers were fitted with an etafilcon A CL in one eye and a polymacon CL in the fellow eye. Lenses were worn on a daily basis by the 26 previous DW SCL wearers and on an EW basis by the remaining 44 subjects. The ocular biota was further sampled after 1, 3, 6, 9, and 12 months of wear. The ocular biota consisted of coagulase-negative staphylococci, Corynebacterium spp., Micrococcus spp., and Propionibacterium spp. Potential pathogens were rarely isolated at baseline. No significant trend of increasing ocular colonization was shown for extended CL wear. Lid and conjunctival colonization increased with DW SCL use (P < 0.001), although this increase occurred for nonpathogenic species only. Fewer potential pathogens were isolated from DW SCL than from EW SCL users (P < 0.05). The lid margin consistently showed greater colonization than the conjunctiva and may be a source of potential pathogens during CL wear. Hydrogel CL wear appears to modify the ocular biota. An increased number of commensal organisms were present in DW SCL use. EW SCL use altered the spectrum of organisms isolated. These alterations may suppress the normal ocular defense mechanisms and may be relevant in the pathogenesis of CL-related disease.
Changes to the ocular biota with time in extended- and daily-wear disposable contact lens use.
Stapleton, F; Willcox, M D; Fleming, C M; Hickson, S; Sweeney, D F; Holden, B A
1995-01-01
Gram-negative bacteria may play a role in the etiology of certain soft contact lens (SCL)-related diseases. Contact lens (CL) wear may modify the normal ocular biota, providing a more favorable environment for potential pathogens. This study reports temporal changes in ocular biota in daily-wear (DW) and extended-wear (EW) disposable SCL use in experienced and neophyte wearers. Lid margin and bulbar conjunctival biota were sampled prior to CL fitting in 26 previous DW SCL users, 18 previous EW SCL users, and 26 neophytes. Wearers were fitted with an etafilcon A CL in one eye and a polymacon CL in the fellow eye. Lenses were worn on a daily basis by the 26 previous DW SCL wearers and on an EW basis by the remaining 44 subjects. The ocular biota was further sampled after 1, 3, 6, 9, and 12 months of wear. The ocular biota consisted of coagulase-negative staphylococci, Corynebacterium spp., Micrococcus spp., and Propionibacterium spp. Potential pathogens were rarely isolated at baseline. No significant trend of increasing ocular colonization was shown for extended CL wear. Lid and conjunctival colonization increased with DW SCL use (P < 0.001), although this increase occurred for nonpathogenic species only. Fewer potential pathogens were isolated from DW SCL than from EW SCL users (P < 0.05). The lid margin consistently showed greater colonization than the conjunctiva and may be a source of potential pathogens during CL wear. Hydrogel CL wear appears to modify the ocular biota. An increased number of commensal organisms were present in DW SCL use. EW SCL use altered the spectrum of organisms isolated. These alterations may suppress the normal ocular defense mechanisms and may be relevant in the pathogenesis of CL-related disease. PMID:7591092
Efficiency of ocular UV protection by clear lenses
Rifai, Katharina; Hornauer, Matthias; Buechinger, Ramona; Schoen, Roland; Barraza-Bernal, Maria; Habtegiorgis, Selam; Glasenapp, Carsten; Wahl, Siegfried; Mappes, Timo
2018-01-01
Ocular UV doses accumulate all-day, not only during periods of direct sun exposure. The UV protection efficiency of three clear lenses was evaluated experimentally, validated by simulation, and compared to non-UV protection: a first spectacle lens with a tailored UV absorber, a second spectacle lens, minimizing UV back reflections, as well as a third spectacle lens, combining both. A tailored UV-absorber efficiently reduced overall UV irradiance to 7 %, whereas reduction of back-reflections still left UV irradiance at 42 %. Thus, clear lenses with a tailored UV absorber efficiently protect the eye from UV, supplementing sun glasses wear to an all-day protection scenario. PMID:29675331
Efficiency of ocular UV protection by clear lenses.
Rifai, Katharina; Hornauer, Matthias; Buechinger, Ramona; Schoen, Roland; Barraza-Bernal, Maria; Habtegiorgis, Selam; Glasenapp, Carsten; Wahl, Siegfried; Mappes, Timo
2018-04-01
Ocular UV doses accumulate all-day, not only during periods of direct sun exposure. The UV protection efficiency of three clear lenses was evaluated experimentally, validated by simulation, and compared to non-UV protection: a first spectacle lens with a tailored UV absorber, a second spectacle lens, minimizing UV back reflections, as well as a third spectacle lens, combining both. A tailored UV-absorber efficiently reduced overall UV irradiance to 7 %, whereas reduction of back-reflections still left UV irradiance at 42 %. Thus, clear lenses with a tailored UV absorber efficiently protect the eye from UV, supplementing sun glasses wear to an all-day protection scenario.
Szczotka-Flynn, Loretta B.; Pearlman, Eric; Ghannoum, Mahmoud
2012-01-01
Purpose A contact lens (CL) can act as a vector for microorganisms to adhere to and transfer to the ocular surface. Commensal microorganisms that uneventfully cohabitate on lid margins and conjunctivae and potential pathogens that are found transiently on the ocular surface can inoculate CLs in vivo. In the presence of reduced tissue resistance, these resident microorganisms or transient pathogens can invade and colonize the cornea or conjunctiva to produce inflammation or infection. Methods The literature was reviewed and used to summarize the findings over the last 30 years on the identification, enumeration, and classification of microorganisms adherent to CLs and their accessories during the course of normal wear and to hypothesize the role that these microorganisms play in CL infection and inflammation. Results Lens handling greatly increases the incidence of lens contamination, and the ocular surface has a tremendous ability to destroy organisms. However, even when removed aseptically from the eye, more than half of lenses are found to harbor microorganisms, almost exclusively bacteria. Coagulase-negative Staphylococci are most commonly cultured from worn lenses; however, approximately 10% of lenses harbor Gram-negative and highly pathogenic species, even in asymptomatic subjects. In storage cases, the incidence of positive microbial bioburden is also typically greater than 50%. All types of care solutions can become contaminated, including up to 30% of preserved products. Conclusions The process of CL-related microbial keratitis and inflammation is thought to be preceded by the presence or transfer or both of microorganisms from the lens to the ocular surface. Thus, this detailed understanding of lens-related bioburden is important in the understanding of factors associated with infectious and inflammatory complications. Promising mechanisms to prevent bacterial colonization on lenses and lens cases are forthcoming, which may decrease the incidence of microbially driven CL complications. PMID:20168237
Temporal properties of compensation for positive and negative spectacle lenses in chicks.
Zhu, Xiaoying; Wallman, Josh
2009-01-01
Chicks' eyes rapidly compensate for defocus imposed by spectacle lenses by changing their rate of elongation and their choroidal thickness. Compensation may involve internal emmetropization signals that rise and become saturated during episodes of lens wear and decline between episodes. The time constants of these signals were measured indirectly by measuring the magnitude of lens compensation in refractive error and ocular dimensions as a function of the duration of episodes and the intervals between the episodes. First, in a study of how quickly the signals rose, chicks were subjected to episodes of lens-wear of various durations (darkness otherwise), and the duration required to cause a half-maximum effect (rise-time) was estimated. Second, in a study of how quickly the signals declined, various dark intervals were imposed between episodes of lens-wear, and the interval required to reduce the maximum effect by half (fall-time) was estimated. The rise-times for the rate of ocular elongation and choroidal thickness were approximately 3 minutes for positive and negative lenses. The fall-times had a broad range of time courses: Positive lenses caused an enduring inhibition of ocular elongation with a fall-time of 24 hours. In contrast, negative lenses caused a transient stimulation of ocular elongation with a fall-time of 0.4 hour. The effects of episodes of defocus rise rapidly with episode duration to an asymptote and decline between episodes, with the time course depending strongly on the sign of defocus and the ocular component. The complex etiology of human myopia may reflect these temporal properties.
Severe pediatric ocular injury due to explosion of a firecracker inside a soda bottle
Shazly, Tarek A
2010-01-01
This case report describes a penetrating ocular injury, followed by endophthalmitis, in a four-year-old girl, resulting from explosion of a small K0201 match-cracker inside a soda bottle. The patient presented with two corneal lacerations, ruptured crystalline lens, multiple intraocular foreign bodies, and hyphema of the right eye, for which immediate surgical exploration and repair was performed. The patient developed aggressive endophthalmitis that led to atrophy of the eye within a few weeks. Severe ocular injuries can result from small, relatively “safe” firecrackers. Therefore, this type of firework should not be used, especially by minors. PMID:27147842
Nickla, Debora L.; Totonelly, Kristen; Dhillon, Balprit
2010-01-01
The dopaminergic system has been implicated in ocular growth regulation in chicks and monkeys. In both, dopamine D2 agonists inhibit the development of myopia in response to form deprivation, and in chicks, to negative lenses as well. Because there is mounting evidence that the choroidal response to defocus plays a role in ocular growth regulation, we asked whether the effective agonists also elicit transient thickening of the choroid concomitant with the growth inhibition. Negative lenses mounted on velcro rings were worn on one eye starting at age 8-12 days. Intravitreal injections (20 μl; dose=10 nmole) of the agonist (dissolved in saline) or saline, were given through the superior temporal sclera using a 30G needle. Eyes were injected daily at noon, for 4 days, and the lenses immediately replaced. Agonists used were apomorphine (non-specific; n=17), quinpirole (D2; n=10), SKF-38393 (D1; n=9), and saline controls (n=22). For the antagonists, the same protocol was used, but on each day, the lenses were removed for 2 hours. Immediately prior to lens-removal, the antagonist was injected (20 μl; dose=5 nmole). Antagonists used were methylergonovine (non-specific; n=12), spiperone (D2; n=20), SCH-23390 (D1 n=6) and saline controls (n=27). Comparisons to saline (continuous lens wear) controls were from the agonist experiment. Axial dimensions were measured using high frequency A-scan ultrasonography at the start of lens wear, and on day 4 prior to the injections, and then again 3 hours later. Refractive errors were measured using a Hartinger's refractometer at the end of the experiment. Apomorphine and quinpirole inhibited the refractive response to the hyperopic defocus induced by the negative lenses (drug vs saline controls: -1.3 and 1.2 D vs -5.6 D; p<0.005 for both). This effect was axial: both drugs prevented the excessive ocular elongation (change in axial length: 233 and 205 μm vs 417 um; p<0.01 for both). Both drugs were also associated with a transient thickening of the choroid over 3 hours (41 and 32 um vs –1 um; p<0.01; p=0.059 respectively) that did not summate: choroids thinned significantly over the 4 day period in all lens-wearing eyes. Two daily hours of unrestricted vision during negative lens wear normally prevents the development of myopia. Spiperone and SCH-23390 inhibited the ameliorating effects of periods of vision on lens-induced refractive error (-2.9 and –2.8 D vs 0.6 D; p<0.0001), however, the effects on neither axial length nor choroidal thickness were significant. These data support a role for both D1 and D2 receptors in the ocular growth responses. PMID:20801115
Versatile optical coherence tomography for imaging the human eye
Tao, Aizhu; Shao, Yilei; Zhong, Jianguang; Jiang, Hong; Shen, Meixiao; Wang, Jianhua
2013-01-01
We demonstrated the feasibility of a CMOS-based spectral domain OCT (SD-OCT) for versatile ophthalmic applications of imaging the corneal epithelium, limbus, ocular surface, contact lens, crystalline lens, retina, and full eye in vivo. The system was based on a single spectrometer and an alternating reference arm with four mirrors. A galvanometer scanner was used to switch the reference beam among the four mirrors, depending on the imaging application. An axial resolution of 7.7 μm in air, a scan depth of up to 37.7 mm in air, and a scan speed of up to 70,000 A-lines per second were achieved. The approach has the capability to provide high-resolution imaging of the corneal epithelium, contact lens, ocular surface, and tear meniscus. Using two reference mirrors, the zero delay lines were alternatively placed on the front cornea or on the back lens. The entire ocular anterior segment was imaged by registering and overlapping the two images. The full eye through the pupil was measured when the reference arm was switched among the four reference mirrors. After mounting a 60 D lens in the sample arm, this SD-OCT was used to image the retina, including the macula and optical nerve head. This system demonstrates versatility and simplicity for multi-purpose ophthalmic applications. PMID:23847729
Guillon, Michel; Dumbleton, Kathy; Theodoratos, Panagiotis; Patel, Trisha; Karkkainen, Tom; Moody, Kurt
2018-05-01
Contact lens wearers of Asian descent may be predisposed to experience microtrauma of the ocular surface as a result a thinner post-lens tear film and higher eyelid tension, and these effects would be anticipated to be most marked in an older population. The objective of this study was to quantify the mechanical effects of the study contact lenses on the ocular surface in a population of presbyopic contact lens wearers of Asian descent. Twenty established presbyopic contact lens wearers (hydrogel n=5, none habitual wearers of etafilcon A lenses; silicone hydrogel n=15) of Asian descent were refitted with etafilcon A multifocal daily disposable contact lenses (1-DAY ACUVUE MOIST MULTIFOCAL) for a period of 1 month of daily lens wear. The habitual modalities of wear were 45% daily disposable and 55% planned replacement. Digital photographs of the upper lid margins, nasal and temporal conjunctiva, and superior cornea were taken after 6 hr of wear of the participants' habitual contact lenses, after 1 day without contact lens wear, and after 6 hr of wear of the study contact lenses at the end of the 1-month period. The photographs were masked according to study visit and the staining extent measured using proprietary software. Lid margin staining was significantly lower with the study contact lenses (2.0±1.0 mm) than with the participants' own contact lenses (3.2±3.0 mm) after 6 hr of wear, representing a mean staining decrease of 38% (P=0.010). Lid margin staining after 6 hr of wear of the study contact lenses was not different from that measured after 1 day without contact lenses (P=0.507). Limbal staining was also significantly less with the study contact lenses than with the participants' own contact lenses after 6 hr of wear (P=0.009). There was minimal upper corneal staining, and the degree was similar with the study and habitual lenses. Etafilcon A material, worn under a daily disposable modality, was shown to reduce upper lid margin and limbal staining in presbyopic contact lens wearers of Asian descent compared with the wearers' own contact lenses. Because of the high preponderance of dry eye amongst presbyopes, material selection is of importance and consideration should be given to the lens-ocular surface interaction.
Choroidal and scleral mechanisms of compensation for spectacle lenses in chicks.
Wildsoet, C; Wallman, J
1995-05-01
It is known that when hyperopic or myopic defocus is imposed on chick eyes by spectacle lenses, they rapidly compensate, becoming myopic or hyperopic respectively, by altering the depth of their vitreous chamber. Changes in two components--ocular length and choroidal thickness--underlie this rapid compensation. With monocular lens treatment, hyperopic defocus imposed by negative lenses resulted in substantially increased ocular elongation and a slight thinning of the choroid, both changes resulting in myopia; myopic defocus imposed by positive lenses resulted a dramatic increase in choroidal thickness, which pushed the retina forward toward the image plane, and a slight decrease in ocular elongation, both changes resulting in hyperopia. The refractive error after 5 days of lens wear correlated well with vitreous chamber depth, which reflected the changes in both choroidal thickness and ocular length. The degree of compensation for lenses was not affected by whether the fellow eye was covered or open. Both form-deprivation myopia and lens-induced myopia declined with age in parallel, but wearing a -15 D lens produced more myopia than did form deprivation. The spectacle lenses affected the refractive error not only of the lens-wearing eye, but also, to a much lesser degree, of the untreated fellow eye. At lens removal refractive errors were opposite in sign to the lense worn, and the subsequent changes in choroidal thickness and ocular length were also opposite to those that occurred when the lenses were in place. In this situation as well, effects of the spectacle lenses on the fellow eyes were observed. Eyes with no functional afferent connection to the brain because of either prior optic nerve section or intraocular tetrodotoxin injections showed compensatory changes to imposed defocus, but these were limited to compensation for imposed myopic defocus, at least for the eyes with optic nerve section. In addition, optic nerve section, but not tetrodotoxin treatment, moved the set-point of the visual compensatory mechanism toward hyperopia. Optic nerve section prevents myopia in response to negative lenses but not to diffusers, suggesting that compensation for hyperopia requires the central nervous system.
In vivo performance of a drug-eluting contact lens to treat glaucoma for a month
Ciolino, Joseph B.; Stefanescu, Cristina F.; Ross, Amy E.; Salvador-Culla, Borja; Cortez, Priscila; Ford, Eden M.; Wymbs, Kate A.; Sprague, Sarah L.; Mascoop, Daniel R.; Rudina, Shireen S.; Trauger, Sunia A.; Cade, Fabiano; Kohane, Daniel S.
2013-01-01
For nearly half a century, contact lenses have been proposed as a means of ocular drug delivery, but achieving controlled drug release has been a significant challenge. We have developed a drug-eluting contact lens designed for prolonged delivery of latanoprost for the treatment of glaucoma, the leading cause of irreversible blindness worldwide. Latanoprost-eluting contact lenses were created by encapsulating latanoprost–poly(lactic-co-glycolic acid) films in methafilcon by ultraviolet light polymerization. In vitro and in vivo studies showed an early burst of drug release followed by sustained release for one month. Contact lenses containing thicker drug–polymer films demonstrated released a greater amount of drug after the initial burst. In vivo, single contact lenses were able to achieve, for at least one month, latanoprost concentrations in the aqueous humor that were comparable to those achieved with topical latanoprost solution, the current first-line treatment for glaucoma. The lenses appeared safe in cell culture and animal studies. This contact lens design can potentially be used as a treatment for glaucoma and as a platform for other ocular drug delivery applications. PMID:24094935
A Prototype Antifungal Contact Lens
Ciolino, Joseph B.; Hudson, Sarah P.; Mobbs, Ashley N.; Hoare, Todd R.; Iwata, Naomi G.; Fink, Gerald R.
2011-01-01
Purpose. To design a contact lens to treat and prevent fungal ocular infections. Methods. Curved contact lenses were created by encapsulating econazole-impregnated poly(lactic-co-glycolic) acid (PLGA) films in poly(hydroxyethyl methacrylate) (pHEMA) by ultraviolet photopolymerization. Release studies were conducted in phosphate-buffered saline at 37°C with continuous shaking. The contact lenses and their release media were tested in an antifungal assay against Candida albicans. Cross sections of the pre- and postrelease contact lenses were characterized by scanning electron microscopy and by Raman spectroscopy. Results. Econazole-eluting contact lenses provided extended antifungal activity against Candida albicans fungi. Fungicidal activity varied in duration and effectiveness depending on the mass of the econazole-PLGA film encapsulated in the contact lens. Conclusions. An econazole-eluting contact lens could be used as a treatment for fungal ocular infections. PMID:21527380
Cell Fate and Differentiation of the Developing Ocular Lens
Greiling, Teri M. S.; Aose, Masamoto
2010-01-01
Purpose. Even though zebrafish development does not include the formation of a lens vesicle, the authors' hypothesis is that the processes of cell differentiation are similar in zebrafish and mammals and determine cell fates in the lens. Methods. Two-photon live embryo imaging was used to follow individual fluorescently labeled cells in real-time from the placode stage at 16 hours postfertilization (hpf) until obvious morphologic differentiation into epithelium or fiber cells had occurred at approximately 28 hpf. Immunohistochemistry was used to label proliferating, differentiating, and apoptotic cells. Results. Similar to the mammal, cells in the teleost peripheral lens placode migrated to the anterior lens mass and differentiated into an anterior epithelium. Cells in the central lens placode migrated to the posterior lens mass and differentiated into primary fiber cells. Anterior and posterior polarization in the zebrafish lens mass was similar to mammalian lens vesicle polarization. Primary fiber cell differentiation was apparent at approximately 21 hpf, before separation of the lens from the surface ectoderm, as evidenced by cell elongation, exit from the cell cycle, and expression of Zl-1, a marker for fiber differentiation. TUNEL labeling demonstrated that apoptosis was not a primary mechanism for lens separation from the surface ectoderm. Conclusions. Despite the absence of a lens vesicle in the zebrafish embryo, lens organogenesis appears to be well conserved among vertebrates. Results using three-dimensional live embryo imaging of zebrafish development showed minimal differences and strong similarities in the fate of cells in the zebrafish and mammalian lens placode. PMID:19834024
2006-07-01
retina . Our experiments have so far been limited to sheep. Our experiments have been designed to address the following questions: 1. Can ocular...We dissected sheep and cow eyes and performed fluorescence spectroscopy on all the major eye components and reports that the cornea, lens, retina ...excitation wavelengths λex = 410, 470, and 520 nm: retina ; optic nerve; outer tissue (sclera); and lens. • Contrary to the conclusions we
Temporal properties of the myopic response to defocus in the guinea pig.
Leotta, Amelia J; Bowrey, Hannah E; Zeng, Guang; McFadden, Sally A
2013-05-01
Hyperopic defocus induces myopia in all species tested and is believed to underlie the progression of human myopia. We determined the temporal properties of the effects of hyperopic defocus in a mammalian eye. In Experiment 1, the rise and decay time of the responses elicited by hyperopic defocus were calculated in 111 guinea pigs by giving repeated episodes of monocular -4 D lens wear (from 5 to 6 days of age for 12 days) interspersed with various dark intervals. In Experiment 2, the decay time constant was calculated in 152 guinea pigs when repeated periods of monocular -5 D lens-wear (from 4 days of age for 7 days) were interrupted with free viewing periods of different lengths. At the end of the lens-wear period, ocular parameters were measured and time constants were calculated relative to the maximum response induced by continuous lens wear. When hyperopic defocus was experienced with dark intervals between episodes, the time required to induce 50% of the maximum achievable myopia and ocular elongation was at most 30 min. Saturated 1 h episodes took at least 22 h for refractive error and 31 h for ocular length, to decay to 50% of the maximum response. However, the decay was an order of magnitude faster when hyperopic defocus episodes were interrupted with a daily free viewing period, with only 36 min required to reduce relative myopia and ocular elongation by 50%. Hyperopic defocus causes myopia with brief exposures and is very long lasting in the absence of competing signals. However, this myopic response rapidly decays if interrupted by periods of 'normal viewing' at least 30 min in length, wherein ocular growth appears to be guided preferentially by the least amount of hyperopic defocus experienced. Ophthalmic & Physiological Optics © 2013 The College of Optometrists.
NASA Astrophysics Data System (ADS)
Kojima, Masami; Suzuki, Yukihisa; Tsai, Cheng-Yu; Sasaki, Kensuke; Wake, Kanako; Watanabe, Soichi; Taki, Masao; Kamimura, Yoshitsugu; Hirata, Akimasa; Sasaki, Kazuyuki; Sasaki, Hiroshi
2015-04-01
In order to investigate changes in ocular temperature in rabbit eyes exposed to different frequencies (18 to 40 GHz) of quasi-millimeter waves, and millimeter waves (MMW). Pigmented rabbits were anesthetized with both general and topical anesthesia, and thermometer probes (0.5 mm in diameter) were inserted into their cornea (stroma), lens (nucleus) and vitreous (center of vitreous). The eyes were exposed unilaterally to 200 mW/cm2 by horn antenna for 3 min at 18, 22 and 26.5 GHz using a K band exposure system or 26.5, 35 and 40 GHz using a Ka band exposure system. Changes in temperature of the cornea, lens and vitreous were measured with a fluoroptic thermometer. Since the ocular temperatures after exposure to 26.5 GHz generated by the K band and Ka band systems were similar, we assumed that experimental data from these 2 exposure systems were comparable. The highest ocular temperature was induced by 40 GHz MMW, followed by 35 GHz. The 26.5 and 22 GHz corneal temperatures were almost the same. The lowest temperature was recorded at 18 GHz. The elevation in ocular temperature in response to exposure to 200 mW/cm2 MMW is dependent on MMW frequency. MMW exposure induced heat is conveyed not only to the cornea but also the crystalline lens.
Low vision rehabilitation and ocular problems among industrial workers in a developing country.
Omar, R; Knight, V F; Aziz Mohammed, M A
2014-01-01
Work-related ocular injuries and illnesses were among the major causes of job absenteeism. This study was conducted to determine if low vision rehabilitation was provided following work-related ocular problems among industrial workers in a developing country. This was a retrospective analysis of case records. Randomly selected records of all employees from the Social Security Organization (SOCSO) Medical Board for 2004 who suffered from ocular injuries and illnesses were selected. Rates of ocular injuries and illnesses according to age, gender, races, types of injuries, types of industries, visual rehabilitation and types of medical interventions were tabulated and analysed. A total of 26 cases of ocular injuries and illnesses were identified where 46.2% suffered from ocular injuries. The remaining 53.8% had ocular and/or systemic diseases. The 40-49-yearold age group suffered the greatest number of injuries (26.92%). Ocular perforating injuries (66.67%) and ocular contusions (33.33%) were the most common types of ocular injury among industrial workers in Kuala Lumpur. Most injuries occurred among workers in the service industry (50%). Almost 60% of these injured workers did not receive any low vision rehabilitation after medical intervention while 25% were given contact lenses or spectacles as rehabilitation and remaining had surgery. The low vision rehabilitation is still unexplored in the management of ocular injuries and illnesses among industrial workers. Introducing low vision rehabilitation can benefit both workers and employers as it provides care beyond spectacles or contact lens prescriptions.
Ozkan, Jerome; Zhu, Hua; Gabriel, Manal; Holden, Brien A; Willcox, Mark D P
2012-03-01
Bacterial contamination of the contact lens surface has been demonstrated to cause corneal infiltrative events. A reduction in the rate of bacterially driven corneal infiltrative events associated with lens wear is one of the major goals of the contact lens industry. There is a concern over the potential of any antimicrobial strategy that there will be unwanted changes to the ocular microbiota or the development of resistance to the antimicrobial. The aim of this study was to investigate the effect of prophylactic topical antibiotic instillation during continuous wear of silicone hydrogel lenses on the normal ocular microbiota, the throat microbiota, and the ocular physiology. Forty-two male subjects were dispensed with lotrafilcon A silicone hydrogel contact lenses for a 3-month, 30 night continuous wear, monthly replacement trial. Subjects were randomized into either tobramycin 0.3% (test) or saline (control) drop group. Two drops were instilled into each eye on waking and before sleep. At monthly visits, lenses were collected aseptically, and ocular and throat swabs were performed, followed by standard microbial recovery and identifications. Any corneal infiltrative event at scheduled or unscheduled visits was recorded. Numbers of microbes recovered from eye swabs from the tobramycin (test) group were significantly lower than the control (p = 0.01). Gram-positive cocci were recovered less frequently from the test group (p = 0.001). There were no significant differences in the numbers and types of microbes recovered from lens samples, or the contamination rate of the lenses between the two groups. There were no changes in the numbers of fungi or bacteria from throat swabs. There was no evidence of changes to resistance profile of microbes in the throat. More eye swabs from the test group (68.5%) were culture-negative than swabs from control (46.5%; p = 0.002). The test group had less corneal staining superiorly (0.0 ± 0.0 vs. 0.3 ± 0.4; p = 0.025) but increased bulbar redness (2.2 ± 0.5 vs. 1.5 ± 0.4; p < 0.001) at the 3-month visit only, compared with control group. Overall, there appeared to be a minimal safety risk with 3-month's prophylactic antibiotic drop use during continuous wear of silicone hydrogel lenses. Clinically, antibiotic drop use induced a mild to moderate increase in bulbar redness by the 3-month time-point. Antibiotic use reduced microbiota on lids but did not affect the microbiota of the throat or change resistance to tobramycin.
Dumbleton, Kathy; Theodoratos, Panagiotis; Patel, Trisha; Karkkainen, Tom; Moody, Kurt
2018-01-01
Introduction: Contact lens wearers of Asian descent may be predisposed to experience microtrauma of the ocular surface as a result a thinner post-lens tear film and higher eyelid tension, and these effects would be anticipated to be most marked in an older population. The objective of this study was to quantify the mechanical effects of the study contact lenses on the ocular surface in a population of presbyopic contact lens wearers of Asian descent. Methods: Twenty established presbyopic contact lens wearers (hydrogel n=5, none habitual wearers of etafilcon A lenses; silicone hydrogel n=15) of Asian descent were refitted with etafilcon A multifocal daily disposable contact lenses (1-DAY ACUVUE MOIST MULTIFOCAL) for a period of 1 month of daily lens wear. The habitual modalities of wear were 45% daily disposable and 55% planned replacement. Digital photographs of the upper lid margins, nasal and temporal conjunctiva, and superior cornea were taken after 6 hr of wear of the participants' habitual contact lenses, after 1 day without contact lens wear, and after 6 hr of wear of the study contact lenses at the end of the 1-month period. The photographs were masked according to study visit and the staining extent measured using proprietary software. Results: Lid margin staining was significantly lower with the study contact lenses (2.0±1.0 mm2) than with the participants' own contact lenses (3.2±3.0 mm2) after 6 hr of wear, representing a mean staining decrease of 38% (P=0.010). Lid margin staining after 6 hr of wear of the study contact lenses was not different from that measured after 1 day without contact lenses (P=0.507). Limbal staining was also significantly less with the study contact lenses than with the participants' own contact lenses after 6 hr of wear (P=0.009). There was minimal upper corneal staining, and the degree was similar with the study and habitual lenses. Conclusions: Etafilcon A material, worn under a daily disposable modality, was shown to reduce upper lid margin and limbal staining in presbyopic contact lens wearers of Asian descent compared with the wearers' own contact lenses. Because of the high preponderance of dry eye amongst presbyopes, material selection is of importance and consideration should be given to the lens–ocular surface interaction. PMID:27755285
Ocular complications of oral contraceptives.
Wood, J R
1977-01-01
The systemic side effects of oral contraceptives are mentioned, and the incidence and variety of ocular complications are discussed. Experimental studies on the ocular effects of oral contraceptives in laboratory animals have shown only increased permeability of the lens and possibly vascular dilatation. Numerous case reports, however, have been published which describe neuroophthalamic, vascular, retinal and macular, aqueous humor dynamic, cornea and contact lense, lens, color vision, and other miscellaneous effects. These reports are reviewed as are the 6 reported prospective studies. These prospective studies reveal only changes in kerotometry readings. Thus the large number of case reports may represent a low overall incidence or may be normal findings in the population as a whole or may be caused by other systemic factors. Until multicenter prospective studies provide definitive guidelines, the risk associated with oral contraceptive use must be kept in its proper perpsective and ocular histories should contain information on oral contraceptive use.
Evaluation of iridociliary and lenticular elasticity using shear-wave elastography in rabbit eyes.
Detorakis, Efstathios T; Drakonaki, Eleni E; Ginis, Harilaos; Karyotakis, Nikolaos; Pallikaris, Ioannis G
2014-01-01
A previous study has employed shear-wave ultrasound elastographic imaging to assess corneal rigidity in an ex-vivo porcine eye model. This study employs the same modality in vivo in a rabbit eye model in order to assess lens, ciliary body and total ocular rigidity changes following the instillation of atropine and pilocarpine. Ten non-pigmented female rabbits were examined. Measurements of the lens, ciliary body and total ocular rigidity as well as lens thickness and anterior chamber depth were taken with the Aixplorer system (SuperSonic Imagine, Aix-en-Provence, France) with the SuperLinear™ SL 15-4 transducer in both eyes at baseline as well as after pilocarpine and atropine instillation. The IOP was also measured with the TonoPen tonometer. Changes in rigidity in the examined areas following atropine instillation were statistically not significant. Ciliary body rigidity was significantly increased whereas lens and total ocular rigidity were significantly reduced following pilocarpine instillation. The decrease in lens rigidity following pilocarpine was significantly associated with the respective increase in ciliary body rigidity. Shear-wave ultrasound elastography can detect in vivo rigidity changes in the anterior segment of the rabbit eye model and may potentially be applied in human eyes, providing useful clinical information on conditions in which rigidity changes play an important role, such as glaucoma, pseudoexfoliation syndrome or presbyopia.
Allergic manifestations of contact lens wearing.
Solomon, Abraham
2016-10-01
Contact lens-induced papillary conjunctivitis (CLPC) is a common ocular allergic disease in contact lens wearers. In its more severe form, it can cause giant papillary conjunctivitis, resulting in contact lens intolerance and the need to discontinue the use of contact lenses. This review presents the pathogenesis, clinical manifestations and management guidelines of this common disorder. Different types of contact lenses are associated with differences in the severity of CLPC. Refitting patients with silicone hydrogel contact lenses or with daily disposable contact lenses may improve the signs and symptoms of CLPC. The recent introduction of the topical immunomodulatory agent tacrolimus in other severe allergic eye diseases may apply in suppressing the allergic inflammation in CLPC as well. CLPC is a common ocular disorder in contact lens wearers, with a significant impact on the quality of vision. It should be promptly recognized by healthcare practitioners and managed by modifications of the types and wearing schedules of contact lenses, as well as novel treatment options with topical immunomodulators.
Mutations in MAB21L2 result in ocular Coloboma, microcornea and cataracts.
Deml, Brett; Kariminejad, Ariana; Borujerdi, Razieh H R; Muheisen, Sanaa; Reis, Linda M; Semina, Elena V
2015-01-01
Ocular coloboma results from abnormal embryonic development and is often associated with additional ocular and systemic features. Coloboma is a highly heterogeneous disorder with many cases remaining unexplained. Whole exome sequencing from two cousins affected with dominant coloboma with microcornea, cataracts, and skeletal dysplasia identified a novel heterozygous allele in MAB21L2, c.151 C>G, p.(Arg51Gly); the mutation was present in all five family members with the disease and appeared de novo in the first affected generation of the three-generational pedigree. MAB21L2 encodes a protein similar to C. elegans mab-21 cell fate-determining factor; the molecular function of MAB21L2 is largely unknown. To further evaluate the role of MAB21L2, zebrafish mutants carrying a p.(Gln48Serfs*5) frameshift truncation (mab21l2Q48Sfs*5) and a p.(Arg51_Phe52del) in-frame deletion (mab21l2R51_F52del) were developed with TALEN technology. Homozygous zebrafish embryos from both lines developed variable lens and coloboma phenotypes: mab21l2Q48Sfs*5 embryos demonstrated severe lens and retinal defects with complete lethality while mab21l2R51_F52del mutants displayed a milder lens phenotype and severe coloboma with a small number of fish surviving to adulthood. Protein studies showed decreased stability for the human p.(Arg51Gly) and zebrafish p.(Arg51_Phe52del) mutant proteins and predicted a complete loss-of-function for the zebrafish p.(Gln48Serfs*5) frameshift truncation. Additionally, in contrast to wild-type human MAB21L2 transcript, mutant p.(Arg51Gly) mRNA failed to efficiently rescue the ocular phenotype when injected into mab21l2Q48Sfs*5 embryos, suggesting this allele is functionally deficient. Histology, immunohistochemistry, and in situ hybridization experiments identified retinal invagination defects, an increase in cell death, abnormal proliferation patterns, and altered expression of several ocular markers in the mab21l2 mutants. These findings support the identification of MAB21L2 as a novel factor involved in human coloboma and highlight the power of genome editing manipulation in model organisms for analysis of the effects of whole exome variation in humans.
Wong, W; Sivak, J G; Moran, K L
2003-01-01
This study determines the relative ocular lens irritancy of 16 common partially transparent or non-transparent consumer hygiene products. The irritancy was found by measuring the changes in the sharpness of focus [referred to as the back vertex distance (BVD) variability] of the cultured bovine lens using a scanning laser In Vitro Assay System. This method consists of a laser beam that scans across the lens, and a computer, which then analyses the average focal length (mm), the BVD variability (mm), and the intensity of the beam transmitted. Lenses were exposed to the 16 hygiene products and the lens' focusing ability was monitored over 192 h. The products are semi-solids or solids (e.g. gels, lotions, shampoos). They are categorized into six groups: shampoos, body washes, lotions, toothpastes, deodorant, and anti-perspirant. Damage (measured by > 1 mm BVD variability) occurred slower for the shampoos, especially in the case of baby shampoo. The results indicate that shampoos exhibit the lowest level of ocular lens toxicity (irritability) while the deodorant is the most damaging.
Slit Lamp-Based Ocular Scoring Systems in Toxicology and Drug Development: A Literature Survey.
Eaton, Joshua Seth; Miller, Paul E; Bentley, Ellison; Thomasy, Sara M; Murphy, Christopher J
2017-12-01
To present a survey of the features of published slit lamp-based scoring systems and their applicability in the context of modern ocular toxicology and drug development. References describing original or modified slit lamp-based scoring systems for human or veterinary clinical patients or in investigative or toxicologic research were collected following a comprehensive literature review using textbooks and online publication searches. Each system's indications and features were compiled to facilitate comparison. Literature review identified 138 original or modified scoring systems. Most (48%) were published for evaluation of the ocular surface, 34% for the general anterior segment, and 18% for the lens. Most systems were described for assessment of human patients (50%) and small albino laboratory species such as rabbits (19%), rats (12%), and mice (8%). Systems described for pigmented laboratory species and for larger species such as dogs, cats, pigs, and nonhuman primates (NHPs) were comparatively underrepresented. No systems described a lens scoring scheme specific to the dog, cat, pig, or NHP. Scoring schemes for aqueous and vitreous cells were infrequently described for laboratory species. Many slit lamp-based scoring systems have been published, but the features of each differ and complicate translation of findings between different species. Use and interpretation of any scoring system in toxicology and drug development must be done with awareness of the limitations of the system being used.
Bayar, Sezin Akca; Pinarci, Eylem Yaman; Karabay, Gulten; Akman, Ahmet; Oto, Sibel; Yilmaz, Gursel
2014-01-01
To report the ocular findings of patients with Alport syndrome and the results of clear lens extraction in this patient group. Twenty-three eyes of 15 patients with a diagnosis of Alport syndrome were included in this study. Clear corneal phacoemulsification and intraocular foldable lens implantation was performed in eyes with indeterminate refractive errors and/or poor visual acuity and anterior capsule samples were analyzed with electron microscopy. All patients had a history of hereditary nephritis and/or deafness as systemic involvement. Ophthalmologic examination revealed anterior lenticonus with high myopia and/or irregular astigmatism in all patients. The mean best-corrected visual acuity (BCVA) was 0.67 ± 0.17 logMAR (range 1.0-0.4) preoperatively and 0.17 ± 0.08 logMAR (range 0.3-0.0) postoperatively. Postoperative refractive lenticular astigmatism dramatically decreased and no ocular complications arose during the follow-up period. Transmission electron microscopic analysis of the lens capsules supported the diagnosis of Alport syndrome. Clear lens phacoemulsification and foldable intraocular lens implantation is a safe and effective therapeutic choice for the management of uncorrectable refractive errors and low visual acuity due to anterior lenticonus in patients with Alport syndrome.
Ocular Effects of Exposure to 40, 75, and 95 GHz Millimeter Waves
NASA Astrophysics Data System (ADS)
Kojima, Masami; Suzuki, Yukihisa; Sasaki, Kensuke; Taki, Masao; Wake, Kanako; Watanabe, Soichi; Mizuno, Maya; Tasaki, Takafumi; Sasaki, Hiroshi
2018-05-01
The objective of this study was to develop a model of ocular damage induced by 40, 75, and 95 GHz continuous millimeter waves (MMW), thereby allowing assessment of the clinical course of ocular damage resulting from exposure to thermal damage-inducing MMW. This study also examined the dependence of ocular damage on incident power density. Pigmented rabbit eyes were exposed to 40, 75, and 95 GHz MMW from a spot-focus-type lens antenna. Slight ocular damage was observed 10 min after MMW exposure, including reduced cornea thickness and reduced transparency. Diffuse fluorescein staining around the pupillary area indicated corneal epithelial injury. Slit-lamp examination 1 day after MMW exposure revealed a round area of opacity, accompanied by fluorescence staining, in the central pupillary zone. Corneal edema, indicative of corneal stromal damage, peaked 1 day after MMW exposure, with thickness gradually subsiding to normal. Three days after exposure, ocular conditions had almost normalized, though corneal thickness was slightly greater than that before exposure. The 50% probability of ocular damage (DD50) was in the order 40 > 95 ≈ 75 GHz at the same incident power densities.
Anterior ocular abnormalities of captive Asian elephants (Elephas maximus indicus) in Thailand.
Kraiwong, Natapong; Sanyathitiseree, Pornchai; Boonprasert, Khajohnpat; Diskul, Phiphatanachatr; Charoenphan, Patara; Pintawong, Weerasak; Thayananuphat, Aree
2016-07-01
To survey and classify anterior ocular abnormalities in 1478 captive Asian elephants (Elephas maximus indicus) in six regions of Thailand. Anterior ocular examination was performed in both eyes (n = 2956) of 1478 elephants selected from the annual health check program involving 2958 animals within six regions of Thailand from January to November 2013. Lesions were described and compared between age and gender. A total of 17.83% (527/2956) of examined eyes from 24.97% (369/1478) of examined elephants had anterior ocular abnormalities. The most common lesions in these examined eyes were frothy ocular discharge (5.85%), corneal edema (5.31%), and conjunctivitis (5.18%). In addition, epiphora, phthisis bulbi, other corneal abnormalities, anterior uveitis, and lens abnormalities were noted. Almost all lesions increased in frequency with age (P < 0.01). Regular ophthalmic examination in elephants should be included in their annual health check program. Early detection and treatment of any ocular abnormality may avoid the development of subsequent irreversible ocular pathology. © 2015 American College of Veterinary Ophthalmologists.
Nickla, Debora L; Totonelly, Kristen; Dhillon, Balprit
2010-11-01
The dopaminergic system has been implicated in ocular growth regulation in chicks and monkeys. In both, dopamine D2 agonists inhibit the development of myopia in response to form deprivation, and in chicks, to negative lenses as well. Because there is mounting evidence that the choroidal response to defocus plays a role in ocular growth regulation, we asked whether the effective agonists also elicit transient thickening of the choroid concomitant with the growth inhibition. Negative lenses mounted on velcro rings were worn on one eye starting at age 8-12 days. Intravitreal injections (20 μl; dose = 10 nmole) of the agonist (dissolved in saline) or saline, were given through the superior temporal sclera using a 30G needle. Eyes were injected daily at noon, for 4 days, and the lenses immediately replaced. Agonists used were apomorphine (non-specific; n = 17), quinpirole (D2; n = 10), SKF-38393 (D1; n = 9), and saline controls (n = 22). For the antagonists, the same protocol was used, but on each day, the lenses were removed for 2 h. Immediately prior to lens-removal, the antagonist was injected (20 μl; dose = 5 nmole). Antagonists used were methylergonovine (non-specific; n = 12), spiperone (D2; n = 20), SCH-23390 (D1; n = 6) and saline controls (n = 27). Comparisons to saline (continuous lens wear) controls were from the agonist experiment. Axial dimensions were measured using high frequency A-scan ultrasonography at the start of lens wear, and on day 4 prior to the injections, and then again 3 h later. Refractive errors were measured using a Hartinger's refractometer at the end of the experiment. Apomorphine and quinpirole inhibited the refractive response to the hyperopic defocus induced by the negative lenses (drug vs saline controls: -1.3 and 1.2 D vs -5.6 D; p < 0.005 for both). This effect was axial: both drugs prevented the excessive ocular elongation (change in axial length: 233 and 205 μm vs 417 μm; p < 0.01 for both). Both drugs were also associated with a transient thickening of the choroid over 3 h (41 and 32 μm vs -1 μm; p < 0.01; p = 0.059 respectively) that did not summate: choroids thinned significantly over the 4 day period in all lens-wearing eyes. Two daily hours of unrestricted vision during negative lens wear normally prevents the development of myopia. Spiperone and SCH-23390 inhibited the ameliorating effects of periods of vision on lens-induced refractive error (-2.9 and -2.8 D vs 0.6 D; p < 0.0001), however, the effects on neither axial length nor choroidal thickness were significant. These data support a role for both D1 and D2 receptors in the ocular growth responses. Copyright © 2010 Elsevier Ltd. All rights reserved.
UV-blocking spectacle lens protects against UV-induced decline of visual performance.
Liou, Jyh-Cheng; Teng, Mei-Ching; Tsai, Yun-Shan; Lin, En-Chieh; Chen, Bo-Yie
2015-01-01
Excessive exposure to sunlight may be a risk factor for ocular diseases and reduced visual performance. This study was designed to examine the ability of an ultraviolet (UV)-blocking spectacle lens to prevent visual acuity decline and ocular surface disorders in a mouse model of UVB-induced photokeratitis. Mice were divided into 4 groups (10 mice per group): (1) a blank control group (no exposure to UV radiation), (2) a UVB/no lens group (mice exposed to UVB rays, but without lens protection), (3) a UVB/UV400 group (mice exposed to UVB rays and protected using the CR-39™ spectacle lens [UV400 coating]), and (4) a UVB/photochromic group (mice exposed to UVB rays and protected using the CR-39™ spectacle lens [photochromic coating]). We investigated UVB-induced changes in visual acuity and in corneal smoothness, opacity, and lissamine green staining. We also evaluated the correlation between visual acuity decline and changes to the corneal surface parameters. Tissue sections were prepared and stained immunohistochemically to evaluate the structural integrity of the cornea and conjunctiva. In blank controls, the cornea remained undamaged, whereas in UVB-exposed mice, the corneal surface was disrupted; this disruption significantly correlated with a concomitant decline in visual acuity. Both the UVB/UV400 and UVB/photochromic groups had sharper visual acuity and a healthier corneal surface than the UVB/no lens group. Eyes in both protected groups also showed better corneal and conjunctival structural integrity than unprotected eyes. Furthermore, there were fewer apoptotic cells and less polymorphonuclear leukocyte infiltration in corneas protected by the spectacle lenses. The model established herein reliably determines the protective effect of UV-blocking ophthalmic biomaterials, because the in vivo protection against UV-induced ocular damage and visual acuity decline was easily defined.
NASA Technical Reports Server (NTRS)
1987-01-01
Used to detect eye problems in children through analysis of retinal reflexes, the system incorporates image processing techniques. VISISCREEN's photorefractor is basically a 35 millimeter camera with a telephoto lens and an electronic flash. By making a color photograph, the system can test the human eye for refractive error and obstruction in the cornea or lens. Ocular alignment problems are detected by imaging both eyes simultaneously. Electronic flash sends light into the eyes and the light is reflected from the retina back to the camera lens. Photorefractor analyzes the retinal reflexes generated by the subject's response to the flash and produces an image of the subject's eyes in which the pupils are variously colored. The nature of a defect, where such exists, is identifiable by atrained observer's visual examination.
Marfan Syndrome in an Iranian Family: A Case Series
Davari, Mohammad Hossein; Kazemi, Toba
2014-01-01
Marfan syndrome (MFS) is a genetic disorder which is inherited by autosomal dominant traits. In MFS, lens displacement and cardiovascular involvement are important causes of morbidity and mortality in the clinical course of the disease. In this case study, the ocular involvement in a family with severe penetration of MFS is reported. Twelve members of a family (father, two daughters, three sons, and six grandchildren) had MFS. Lens ectopia was the most common ophthalmic involvement among the family (100%). Other ocular involvements were as follows; Hypoplastic iris or ciliary’s muscle hypoplasia (50%), on gated eyeball (42%), flat cornea (30%), glaucoma and cataract (25%), retinal detachment (16%). Three members of the family underwent eye surgery including lens extraction, glaucoma surgery and retinal surgery. PMID:25031493
Ultrasonographic biometry of the normal eye of the Persian cat.
Mirshahi, A; Shafigh, S H; Azizzadeh, M
2014-07-01
To describe the normal ultrasonographic biometry of the Persian cat's eyes using B-mode ultrasonography. In a cross-sectional study, 20 healthy Persian cats with no history of previous ophthalmic disease were examined. Ocular biometry of the left and right eyes was measured using B-mode ultrasonography. Comparison of the average measurements between left and right eyes and between vertical and horizontal planes was performed using paired-sample t test. Correlation of ocular parameters with sex, age, head circumference and eye colour was evaluated. Mean ± standard deviation (SD) measurements of the ocular structures of anterior chamber, lens thickness, vitreous chamber and anterior to posterior dimension of the globe in 40 eyes were 4.1 ± 0.7, 7.7 ± 0.5, 8.2 ± 0.4 and 20.7 ± 1.0 mm, respectively. No significant difference was found between the ocular biometry of the left and right eyes or the horizontal and vertical planes. Of the ocular parameters, the following had a significant positive correlation with head circumference: axial globe length, anterior chamber and lens thickness. The vitreous body had a positive correlation with age. Regarding the breed predisposition of Persian cats to ocular problems, the present study provides baseline information for further clinical investigations of ocular abnormalities using B-mode ultrasonography. © 2014 Australian Veterinary Association.
Bell, Cynthia M; Pot, Simon A; Dubielzig, Richard R
2013-05-01
To summarize the clinical and pathologic findings in a group of dogs and cats with progressive clinical ocular disease, which were diagnosed with suppurative endophthalmitis and lens capsule rupture. Twenty cats and forty-six dogs that underwent unilateral enucleation or evisceration for intractable uveitis and/or glaucoma. Biopsy submission requests and microscopic case material were evaluated for clinical and histological features, including history of ocular trauma, duration of ocular disease, pattern of inflammation, and the presence of intralenticular microorganisms. The median duration for cats and dogs was 6 and 5 weeks, respectively. A history of trauma was reported for four (20%) cats and 18 (39%) dogs. All confirmed cases of trauma-three in cats and 14 in dogs-were caused by a cat scratch. Microscopically, all cases had suppurative endophthalmitis centered on the lens, lens capsule rupture, cataract, and lenticular abscess. Infectious organisms were identified by Gram stain within the lens of 14 (70%) cats and 30 (65%) dogs. Gram-positive cocci were seen most commonly. Male cats were overrepresented as compared to females. There were no apparent gender, age or breed predilections in dogs. A unique pattern of slowly progressive or delayed-onset endophthalmitis with lens capsule rupture, lenticular abscess, and frequently intralenticular microorganisms is associated with traumatic penetration of the globe and lens capsule. The term Septic Implantation Syndrome (SIS) is favored in lieu of 'phacoclastic uveitis' to avoid confusion with phacolytic uveitis and to clearly implicate the role of intralenticular microorganisms in the pathogenesis. © 2012 American College of Veterinary Ophthalmologists.
An Epha4/Sipa1l3/Wnt pathway regulates eye development and lens maturation.
Rothe, Melanie; Kanwal, Noreen; Dietmann, Petra; Seigfried, Franziska A; Hempel, Annemarie; Schütz, Desiree; Reim, Dominik; Engels, Rebecca; Linnemann, Alexander; Schmeisser, Michael J; Bockmann, Juergen; Kühl, Michael; Boeckers, Tobias M; Kühl, Susanne J
2017-01-15
The signal-induced proliferation-associated family of proteins comprises four members, SIPA1 and SIPA1L1-3. Mutations of the human SIPA1L3 gene result in congenital cataracts. In Xenopus, loss of Sipa1l3 function led to a severe eye phenotype that was distinguished by smaller eyes and lenses including lens fiber cell maturation defects. We found a direct interaction between Sipa1l3 and Epha4, building a functional platform for proper ocular development. Epha4 deficiency phenocopied loss of Sipa1l3 and rescue experiments demonstrated that Epha4 acts upstream of Sipa1l3 during eye development, with both Sipa1l3 and Epha4 required for early eye specification. The ocular phenotype, upon loss of either Epha4 or Sipa1l3, was partially mediated by rax We demonstrate that canonical Wnt signaling is inhibited downstream of Epha4 and Sipa1l3 during normal eye development. Depletion of either Sipa1l3 or Epha4 resulted in an upregulation of axin2 expression, a direct Wnt/β-catenin target gene. In line with this, Sipa1l3 or Epha4 depletion could be rescued by blocking Wnt/β-catenin or activating non-canonical Wnt signaling. We therefore conclude that this pathomechanism prevents proper eye development and maturation of lens fiber cells, resulting in congenital cataracts. © 2017. Published by The Company of Biologists Ltd.
Morphologic analysis of artifacts in human fetal eyes confounding histopathologic investigations.
Herwig, Martina C; Müller, Annette M; Holz, Frank G; Loeffler, Karin U
2011-04-25
Human fetal eyes are an excellent source for studies of the normal ocular development and for examining early ocular changes associated with various syndromes in the context of a pediatric pathologic or prenatal sonographic diagnosis. However, artifacts caused by different factors often render an exact interpretation difficult. In this study, the frequency and extent of artifacts in human fetal eyes were investigated with the aim of distinguishing more precisely these artifacts from real findings, allowing also for a more diligent forensic interpretation. The cohort included 341 fetal eyes, ranging in age from 8 to 38 weeks of gestation, that were investigated macroscopically and by light microscopy. In most specimens, artifacts such as pigment spillage and autolytic changes of the retina were noted. Nearly all specimens showed changes of the lens with remarkable similarities to cataractous lenses in adult eyes. Structural ocular changes associated with systemic syndromes were also observed and in most instances could be distinguished from artifacts. Morphologic changes in fetal eyes should be classified in artifacts caused by way of abortion, mechanical effects from the removal of the eyes, delayed fixation with autolysis, and the fixative itself and should be distinguished from genuine structural abnormalities associated with ocular or systemic disease. This classification can be fairly difficult and requires experience. In addition, lens artifacts are often misleading, and the diagnosis of a fetal cataract should not be made based on histopathologic examination alone.
Kassab, A
2012-02-01
The ultrasonographic appearance and measurements of the normal buffalo and camel eye globes were described in 60 buffaloes (Bos bubalis) aged 1 year (28 eyes) and 10 years (32 eyes), and in 51 humped camels (Camelus dromedarius) aged 1 year (26 eyes) and 10 years (24 eyes). Ocular measurements were recorded by A- and B-scan ultrasonographic examination of 40 buffalo eyes (18 young and 22 adult eyes) and 34 camel eyes (14 young and 20 adult eyes) using a KANGH ultrasound scanner equipped with 10 MHz probe. For gross measurements, 20 buffalo and 16 camel eye globes were frozen and dissected and the same measurements were made using fine callipers macroscopically. The aqueous and vitreous humour of the buffalo and camel eyes appeared anechoic. The cornea, anterior and posterior lens capsule and iris appeared hyperechoic. The ocular measurements for the axial length, vitreous chamber depth (VCD), corneal thickness, lens thickness and scleroretinal rim thickness increase with the advance of age in both buffaloes and camels. Except for the anterior chamber depth, VCD and lens thickness, which were larger in adult camels than in adult buffaloes, no other differences between ocular dimensions were observed in both species. The results of this study are valuable for comparative ocular anatomy and will be useful for ultrasonographic evaluation of ocular diseases in buffaloes and camels. © 2011 Blackwell Verlag GmbH.
Protein Disulfide Levels and Lens Elasticity Modulation: Applications for Presbyopia
Garner, William H.; Garner, Margaret H.
2016-01-01
Purpose The purpose of the experiments described here was to determine the effects of lipoic acid (LA)-dependent disulfide reduction on mouse lens elasticity, to synthesize the choline ester of LA (LACE), and to characterize the effects of topical ocular doses of LACE on mouse lens elasticity. Methods Eight-month-old mouse lenses (C57BL/6J) were incubated for 12 hours in medium supplemented with selected levels (0–500 μM) of LA. Lens elasticity was measured using the coverslip method. After the elasticity measurements, P-SH and PSSP levels were determined in homogenates by differential alkylation before and after alkylation. Choline ester of LA was synthesized and characterized by mass spectrometry and HPLC. Eight-month-old C57BL/6J mice were treated with 2.5 μL of a formulation of 5% LACE three times per day at 8-hour intervals in the right eye (OD) for 5 weeks. After the final treatment, lenses were removed and placed in a cuvette containing buffer. Elasticity was determined with a computer-controlled instrument that provided Z-stage upward movements in 1-μm increments with concomitant force measurements with a Harvard Apparatus F10 isometric force transducer. The elasticity of lenses from 8-week-old C57BL/6J mice was determined for comparison. Results Lipoic acid treatment led to a concentration-dependent decrease in lens protein disulfides concurrent with an increase in lens elasticity. The structure and purity of newly synthesized LACE was confirmed. Aqueous humor concentrations of LA were higher in eyes of mice following topical ocular treatment with LACE than in mice following topical ocular treatment with LA. The lenses of the treated eyes of the old mice were more elastic than the lenses of untreated eyes (i.e., the relative force required for similar Z displacements was higher in the lenses of untreated eyes). In most instances, the lenses of the treated eyes were even more elastic than the lenses of the 8-week-old mice. Conclusions As the elasticity of the human lens decreases with age, humans lose the ability to accommodate. The results, briefly described in this abstract, suggest a topical ocular treatment to increase lens elasticity through reduction of disulfides to restore accommodative amplitude. PMID:27233034
NASA Technical Reports Server (NTRS)
Ansari, Rafat R.; King, James F.; Giblin, Frank J.
2000-01-01
Human exploration of Mars is a key goal in NASA's exploration planning in the next 20 years. Maintaining crew health and good vision is certainly an important aspect of achieving a successful mission. Continuous radiation exposure is a risk factor for radiation-induced cataracts in astronauts because radiation exposure in space travel has the potential of accelerating the aging process (ref. 1). A patented compact device (ref. 2) based on the technique of dynamic light scattering (DLS) was designed for monitoring an astronaut's ocular health during long-duration space travel. This capability of early diagnosis, unmatched by any other clinical technique in use today, may enable prompt initiation of preventive/curative therapy. An Internet web-based system integrating photon correlation data and controlling the hardware to monitor cataract development in vivo at a remote site in real time (teleophthalmology) is currently being developed. The new technology detects cataracts very early (at the molecular level). Cataract studies onboard the International Space Station will be helpful in quantifying any adverse effect of radiation to ocular health. The normal lens in a human eye, situated behind the cornea, is a transparent tissue. It contains 35 wt % protein and 65 wt % water. Aging, disease (e.g., diabetes), smoking, dehydration, malnutrition, and exposure to ultraviolet light and ionizing radiation can cause agglomeration of the lens proteins. Protein aggregation can take place anywhere in the lens, causing lens opacity. The aggregation and opacification could produce nuclear (central portion of the lens) or cortical (peripheral) cataracts. Nuclear and posterior subcapsular (the membrane's capsule surrounds the whole lens) cataracts, being on the visual optical axis of the eye, cause visual impairment that can finally lead to blindness. The lens proteins, in their native state, are small in size. As a cataract develops, this size grows from a few nanometers (transparent) to several micrometers (cloudy). Ansari and Datiles have shown that DLS can detect cataracts at least two to three orders of magnitude earlier noninvasively and quantitatively than the best imaging (Scheimpflug) techniques in clinical use today (ref. 3).
Kampik, A; Rapp, J
1979-02-01
A method of Cinematography of the ocular fundus is introduced which--by connecting a camera with an indirect ophthalmoscop--allows to record the monocular picture of the fundus as produced by the ophthalmic lens.
Huang, Juan; Hung, Li-Fang; Smith, Earl L.
2012-01-01
This study aimed to investigate the changes in ocular shape and relative peripheral refraction during the recovery from myopia produced by form deprivation (FD) and hyperopic defocus. FD was imposed in 6 monkeys by securing a diffuser lens over one eye; hyperopic defocus was produced in another 6 monkeys by fitting one eye with -3D spectacle. When unrestricted vision was re-established, the treated eyes recovered from the vision-induced central and peripheral refractive errors. The recovery of peripheral refractive errors was associated with corresponding changes in the shape of the posterior globe. The results suggest that vision can actively regulate ocular shape and the development of central and peripheral refractions in infant primates. PMID:23026012
Bacterial Coaggregation Among the Most Commonly Isolated Bacteria From Contact Lens Cases.
Datta, Ananya; Stapleton, Fiona; Willcox, Mark D P
2017-01-01
To examine the coaggregation and cohesion between the commonly isolated bacteria from contact lens cases. Four or five strains each of commonly isolated bacteria from contact lens cases, Staphylococcus aureus, Staphylococcus epidermidis, Pseudomonas aeruginosa, and Serratia marcescens, were grown, washed, mixed in equal proportions, and allowed to coaggregate for 24 hours. Lactose (0.06 M), sucrose (0.06 M), and pronase (2 mg/mL; 2 hours, 37°C) were used to inhibit coaggregation. Oral bacterial isolates of Actinomyces naeslundii and Streptococcus sanguinis were used as a positive control for coaggregation. Cohesion was performed with the ocular bacteria that demonstrated the highest level of coaggregation. Production of growth-inhibitory substances was measured by growing strains together on agar plates. The oral bacterial pair showed >80% coaggregation. Coaggregation occurred between ocular strains of S. aureus (2/5) or S. epidermidis (2/5) with P. aeruginosa strains (3/5); 42% to 62%. There was only slight coaggregation between staphylococci and S. marcescens. Staphylococcus aureus coaggregated with S. epidermidis. Lactose or sucrose treatment of S. aureus but pronase treatment of P. aeruginosa reversed the coaggregation. There was no cohesion between the ocular isolates. P. aeruginosa was able to stop growth of S. aureus but not vice versa. This study demonstrated for the first time that ocular isolates of P. aeruginosa and S. aureus could coaggregate, probably through lectin-carbohydrate interactions. However, this may not be related to biofilm formation in contact lens cases, as there was no evidence that the coaggregation was associated with cohesion between the strains.
Presence of Acanthamoeba in the ocular surface in a Spanish population of contact lens wearers.
Rodríguez-Martín, Javier; Rocha-Cabrera, Pedro; Reyes-Batlle, María; López-Arencibia, Atteneri; Sifaoui, Ines; Rizo-Liendo, Aitor; Bethencourt-Estrella, Carlos J; Piñero, José E; Lorenzo-Morales, Jacob
2018-06-26
Pathogenic strains of Acanthamoeba are causative agents of a sight-threatening infection of the cornea known as Acanthamoeba keratitis (AK) which mainly affects contact lens wearers and it is commonly related to poor hygiene of contact lenses and their cases. Moreover, treatment of AK is complex due to the existence of a highly resistant cyst stage and if not diagnosed early has poor prognosis, leading to blindness and/or keratoplasty. Even though AK is increasing worldwide as well as awareness among patients and clinicians, it is still a poorly studied pathogen. Additionally, a remaining question to be answered is whether these opportunistic pathogens are present in the ocular surface of healthy contact lens wearers since they are the main group at risk.In order to carry out this study, sterile Schirmer strip tests were collected from a group of individuals all of them contact lens wearers who were attending a local ophthalmology clinic in Tenerife, Canary Islands, Spain. The collected samples (100 eyes of 50 patients) were cultured in 2% Non-Nutrient Agar (NNA) plates and positive plates (16) were then cultured in axenic conditions for further analyses. Molecular analysis classified all isolated strains belonged to Acanthamoeba genotype T4 and osmotolerance and thermotolerance assays revealed that all strains were potentially pathogenic. In conclusion, the ocular surface of contact lens wearers included in this study was colonized by potentially pathogenic strains of Acanthamoeba and should be considered as a risk for AK infection in this region and worldwide.
Lid wiper microvascular responses as an indicator of contact lens discomfort
Deng, Zhihong; Wang, Jianhua; Jiang, Hong; Fadli, Zohra; Liu, Che; Tan, Jia; Zhou, Jin
2016-01-01
Purpose To analyze quantitatively the alterations in the microvascular network of the upper tarsal conjunctiva, lid wiper, and bulbar conjunctiva relative to ocular discomfort after contact lens wear. Design A prospective, cross-over clinical study. Methods Functional slit-lamp biomicroscopy (FSLB) was used to image the microvascular network of the upper tarsal conjunctiva, lid wiper, and bulbar conjunctiva. The microvascular network was automatically segmented, and fractal analyses were performed to yield the fractal dimension (Dbox) that represented vessel density. Sixteen healthy subjects (nine female and seven male) with an average age of 35.5 ± 6.7 years old (mean ± standard deviation) were recruited. The right eye was imaged at 9 AM and 3 PM at the first visit (Day 1) when the subject was not wearing contact lenses. During the second visit (Day 2), the right eye was fit with a contact lens for 6 h. Microvascular imaging was performed before (at 9 AM) and after lens wear (at 3 PM). Ocular comfort was rated using a 50-point visual analogue scale before and after 6 h of lens wear, and its relationships with microvascular parameters were analyzed. Results There were no significant differences in Dbox among the upper tarsal conjunctiva, lid wiper, and bulbar conjunctiva among the measurements at 9 AM (Day 1 and Day 2) and 3 PM (Day 1) when the subjects were not wearing the lenses (P > 0.05), whereas after 6 h of lens wear, the microvascular network densities were increased in all three of these locations. Dbox of the lid wiper increased from 1.411 ± 0.116 to 1.548 ± 0.079 after 6 h of contact lens wear (P < 0.01). Dbox of the tarsal conjunctiva was 1.731 ± 0.026 at baseline and increased to 1.740 ± 0.030 (P < 0.05). Dbox of the bulbar conjunctiva increased from 1.587 ± 0.059 to 1.632 ± 0.060 (P < 0.001). The decrease in ocular discomfort was strongly related to the Dbox change in the lid wiper (r = 0.61, P < 0.05). There were no correlations between the changes of ocular comfort and the microvascular network densities of either the tarsal or bulbar conjunctivas (P > 0.05). Conclusion This study is the first to show that the microvascular network of the lid wiper can be quantitatively analyzed in contact lens wearers. The microvascular responses of the lid wiper were significantly correlated with contact lens discomfort. PMID:27542928
Spectacle-related eye injuries, spectacle-impact performance and eye protection.
Hoskin, Annette K; Philip, Swetha; Dain, Stephen J; Mackey, David A
2015-05-01
The aim was to review the prevalence of spectacle-related ocular trauma and the performance of currently available spectacle materials and to identify the risk factors associated with spectacle-related ocular trauma. A literature review was conducted using Medline, Embase and Google with the keywords 'eyeglasses' OR 'spectacles' AND 'ocular injury' / 'eye injury'/ 'eye trauma' / 'ocular trauma'. Articles published prior to 1975 were excluded from this review because of advances in spectacle lens technology and Food and Drug Administration legislative changes requiring impact resistance of all prescription spectacle lenses in the United States. Six hundred and ninety-five individual ocular traumas, for which spectacles contributed to or were the main cause of injury, were identified in the literature. Eye injuries occurred when spectacles were worn in sports, in which medium- to high-impact energies were exerted from balls, racquets or bats and/or as a result of a collision with another player. Frame, lens design and product material choice were found to be associated with ocular injury, with polycarbonate lenses cited as the material of choice in the literature. International, regional and national standards for spectacle lenses had a wide range of impact requirements for prescription spectacle lenses, sports eye protection and occupational eye protection. Spectacle-related injury represents a small but preventable cause of ocular injury. With the increasing numbers of spectacle wearers and calls to spend more time outdoors to reduce myopia, spectacle wearers need to be made aware of the potential risks associated with wearing spectacles during medium- to high-risk activities. At particular risk are those prone to falls, the functionally one-eyed, those who have corneal thinning or have had previous eye surgery or injury. With increased understanding of specific risk factors, performance guidelines can be developed for prescription spectacle eye-protection requirements. © 2015 The Authors. Clinical and Experimental Optometry © 2015 Optometry Australia.
Yildiz Tasci, Yelda; Gürdal, Canan; Sarac, Ozge; Onusever, Aykut
2017-07-01
To evaluate the effects of three different silicone hydrogel contact lenses (SHCL), (balafilcon A, senofilcon A, and comfilcon A) on tear function tests, corneal thickness, and ocular surface cytology in first time contact lens users. In this prospective study, 120 eyes of 60 subjects were evaluated. Balafilcon A users were designated as group 1, senofilcon A users as group 2, and comfilcon A users as group 3. In all cases, before and after 6 months of contact lens wear, ocular surface disease index score (OSDI), tear breakup time (TBUT), Schirmer 1 test, central corneal thickness (CCT), central corneal epithelium thickness (CCET), and conjunctival impression cytology samples were evaluated. In group 1, 40 eyes of the 20 patients, in group 2, 40 eyes of the 20 patients, and in group 3, 40 eyes of the 20 patients were evaluated. The mean OSDI scores did not differ between the three groups after contact lens wear (p > 0.05). In group 1 and group 2, significant decrease was found in the mean TBUT 6 months after contact lens wear (p = 0.04, p < 0.001, respectively). In group 3, after 6 months of contact lens wear, the mean Schirmer 1 tear test was decreased significantly (p = 0.021). In all 3 groups, no significant change was observed in the mean CCT and CCET after contact lens wear (p > 0.05). After 6 months, the morphological changes in temporal and superior conjunctival epithelial cells were found to be significant in all groups (p < 0.001). Six months after SHCL wear, marked morphological changes occurred in the conjunctival epithelium. Tear function tests were also affected, while corneal thickness did not show any significant difference.
Noninvasive Diagnostic Devices for Diabetes through Measuring Tear Glucose
Zhang, Jin; Hodge, William; Hutnick, Cindy; Wang, Xianbin
2011-01-01
This article reviews the development of a noninvasive diagnostic for diabetes by detecting ocular glucose. Early diagnosis and daily management are very important to diabetes patients to ensure a healthy life. Commercial blood glucose sensors have been used since the 1970s. Millions of diabetes patients have to prick their finger for a drop of blood 4–5 times a day to check blood glucose levels—almost 1800 times annually. There is a strong need to have a noninvasive device to help patients to manage the disease easily and painlessly. Instead of detecting the glucose in blood, monitoring the glucose level in other body fluids may provide a feasible approach for noninvasive diagnosis and diabetes control. Tear glucose has been studied for several decades. This article reviews studies on ocular glucose and its monitoring methods. Attempts to continuously monitor the concentration of tear glucose by using contact lens-based sensors are discussed as well as our current development of a nanostructured lens-based sensor for diabetes. This disposable biosensor for the detection of tear glucose may provide an alternative method to help patients manage the disease conveniently. PMID:21303640
NASA Astrophysics Data System (ADS)
Wu, Chen; Aglyamov, Salavat R.; Liu, Chih-Hao; Han, Zhaolong; Singh, Manmohan; Larin, Kirill V.
2017-02-01
Many ocular diseases such as glaucoma and uveitis can lead to the elevation of intraocular pressure (IOP). Previous research implies a link between elevated IOP and lens disease. However, the relationship between IOP elevation and biomechanical properties of the crystalline lens has not been directly studied yet. In this work, we investigated the biomechanical properties of porcine lens as a function of IOP by acoustic radiation force optical coherence elastography.
Ultraviolet vision in birds: the importance of transparent eye media
Lind, Olle; Mitkus, Mindaugas; Olsson, Peter; Kelber, Almut
2014-01-01
Ultraviolet (UV)-sensitive visual pigments are widespread in the animal kingdom but many animals, for example primates, block UV light from reaching their retina by pigmented lenses. Birds have UV-sensitive (UVS) visual pigments with sensitivity maxima around 360–373 nm (UVS) or 402–426 nm (violet-sensitive, VS). We describe how these pigments are matched by the ocular media transmittance in 38 bird species. Birds with UVS pigments have ocular media that transmit more UV light (wavelength of 50% transmittance, λT0.5, 323 nm) than birds with VS pigments (λT0.5, 358 nm). Yet, visual models predict that colour discrimination in bright light is mostly dependent on the visual pigment (UVS or VS) and little on the ocular media. We hypothesize that the precise spectral tuning of the ocular media is mostly relevant for detecting weak UV signals, e.g. in dim hollow-nests of passerines and parrots. The correlation between eye size and UV transparency of the ocular media suggests little or no lens pigmentation. Therefore, only small birds gain the full advantage from shifting pigment sensitivity from VS to UVS. On the other hand, some birds with VS pigments have unexpectedly low UV transmission of the ocular media, probably because of UV blocking lens pigmentation. PMID:24258716
Ultraviolet vision in birds: the importance of transparent eye media.
Lind, Olle; Mitkus, Mindaugas; Olsson, Peter; Kelber, Almut
2014-01-07
Ultraviolet (UV)-sensitive visual pigments are widespread in the animal kingdom but many animals, for example primates, block UV light from reaching their retina by pigmented lenses. Birds have UV-sensitive (UVS) visual pigments with sensitivity maxima around 360-373 nm (UVS) or 402-426 nm (violet-sensitive, VS). We describe how these pigments are matched by the ocular media transmittance in 38 bird species. Birds with UVS pigments have ocular media that transmit more UV light (wavelength of 50% transmittance, λ(T0.5), 323 nm) than birds with VS pigments (λ(T0.5), 358 nm). Yet, visual models predict that colour discrimination in bright light is mostly dependent on the visual pigment (UVS or VS) and little on the ocular media. We hypothesize that the precise spectral tuning of the ocular media is mostly relevant for detecting weak UV signals, e.g. in dim hollow-nests of passerines and parrots. The correlation between eye size and UV transparency of the ocular media suggests little or no lens pigmentation. Therefore, only small birds gain the full advantage from shifting pigment sensitivity from VS to UVS. On the other hand, some birds with VS pigments have unexpectedly low UV transmission of the ocular media, probably because of UV blocking lens pigmentation.
Shama, Gilbert; Andrew, Peter W.
2016-01-01
Currently there are estimated to be approximately 3.7 million contact lens wearers in the United Kingdom and 39.2 million in North America. Contact lens wear is a major risk factor for developing an infection of the cornea known as keratitis due to poor lens hygiene practices. While there is an international standard for testing disinfection methods against bacteria and fungi (ISO 14729), no such guidelines exist for the protozoan Acanthamoeba, which causes a potentially blinding keratitis most commonly seen in contact lens wearers, and as a result, many commercially available disinfecting solutions show incomplete disinfection after 6 and 24 h of exposure. Challenge test assays based on international standard ISO 14729 were used to determine the antimicrobial activity of cold atmospheric gas plasma (CAP) against Pseudomonas aeruginosa, Candida albicans, and trophozoites and cysts of Acanthamoeba polyphaga and Acanthamoeba castellanii. P. aeruginosa and C. albicans were completely inactivated in 0.5 min and 2 min, respectively, and trophozoites of A. polyphaga and A. castellanii were completely inactivated in 1 min and 2 min, respectively. Furthermore, for the highly resistant cyst stage of both species, complete inactivation was achieved after 4 min of exposure to CAP. This study demonstrates that the CAP technology is highly effective against bacterial, fungal, and protozoan pathogens. The further development of this technology has enormous potential, as this approach is able to deliver the complete inactivation of ocular pathogens in minutes, in contrast to commercial multipurpose disinfecting solutions that require a minimum of 6 h. PMID:26994079
Heterochromatic Flicker Photometry for Objective Lens Density Quantification.
Najjar, Raymond P; Teikari, Petteri; Cornut, Pierre-Loïc; Knoblauch, Kenneth; Cooper, Howard M; Gronfier, Claude
2016-03-01
Although several methods have been proposed to evaluate lens transmittance, to date there is no consensual in vivo approach in clinical practice. The aim of this study was to compare ocular lens density and transmittance measurements obtained by an improved psychophysical scotopic heterochromatic flicker photometry (sHFP) technique to the results obtained by three other measures: a psychophysical threshold technique, a Scheimpflug imaging technique, and a clinical assessment using a validated subjective scale. Forty-three subjects (18 young, 9 middle aged, and 16 older) were included in the study. Individual lens densities were measured and transmittance curves were derived from sHFP indexes. Ocular lens densities were compared across methods by using linear regression analysis. The four approaches showed a quadratic increase in lens opacification with age. The sHFP technique revealed that transmittance decreased with age over the entire visual spectrum. This decrease was particularly pronounced between young and older participants in the short (53.03% decrease in the 400-500 nm range) wavelength regions of the light spectrum. Lens density derived from sHFP highly correlated with the values obtained with the other approaches. Compared to other objective measures, sHFP also showed the lowest variability and the best fit with a quadratic trend (r2 = 0.71) of lens density increase as a function of age. The sHFP technique offers a practical, reliable, and accurate method to measure lens density in vivo and predict lens transmittance over the visible spectrum. An accurate quantification of lens transmittance should be obtained in clinical practice, but also in research in visual and nonvisual photoreception.
The molecular mechanisms underlying lens fiber elongation
Audette, Dylan S.; Scheiblin, David A.; Duncan, Melinda K.
2016-01-01
Lens fiber cells are highly elongated cells with complex membrane morphologies that are critical for the transparency of the ocular lens. Investigations into the molecular mechanisms underlying lens fiber cell elongation were first reported in the 1960s, however, our understanding of the process is still poor nearly 50 years later. This review summarizes what is currently hypothesized about the regulation of lens fiber cell elongation along with the available experimental evidence, and how this information relates to what is known about the regulation of cell shape/elongation in other cell types, particularly neurons. PMID:27015931
Contact lens strategies for the patient with dry eye.
Sindt, Christine W; Longmuir, Reid A
2007-10-01
Dry eye is the most common reason for contact lens (CL) discontinuation, and the patient with pre-existing dry eye presents particular challenges to the CL fitter. Poor tear film quality/stability, oxygen deprivation, lens deposits, and adverse reactions to CL solutions all contribute to dry eye, and lid disease, allergies, environmental factors, and medications can further hamper successful CL wear by the patient with dry eye. Health and comfort of the ocular surface is affected by the water content, ionicity, oxygen permeability, and modulus of elasticity of the lens, as well as by surface characteristics, such as protein, lipid, and mucin deposition; protein adsorption; and wettability. The choice of CL cleaning solutions with regard to action, cytotoxicity, and biocompatibility are as important as the choice of the CL itself. With appropriate management of the lid, meibomian gland, and ocular surface conditions that produce dry eye, careful selection of lenses and solutions, and vigilant follow-up, successful CL wear should be achievable for the dry eye patient.
Spectral and time-resolved studies on ocular structures
NASA Astrophysics Data System (ADS)
Schweitzer, D.; Jentsch, S.; Schenke, S.; Hammer, M.; Biskup, C.; Gaillard, E.
2007-07-01
Measurements of endogeous fluorophores open the possibility for evaluation of metabolic state at the eye. For interpretation of 2-dimensional measurements of time-resolved auto fluorescence in 2 separate spectral ranges at the human eye, comparing measurements were performed on porcine eyes. Determining excitation and emission spectra, attention was drawn of proof of coenzymes NADH and FAD in isolated anatomical structures cornea, aqueous humor, lens, vitreous, neuronal retina, retinal pigment epithelium (RPE), choroid, and sclera. All these structures exhibit auto fluorescence, highest in lens. Excitation at 350 nm results in local fluorescence maxima at 460 nm, corresponding to NADH, in all structures. This short-wave excitation allows metabolic studies only at the anterior eye, because of the limited transmission of the ocular media. During excitation at 446 nm the existence of FAD is expressed by local fluorescence maxima at 530 nm. The composition fluorescence spectra allow no discrimination between single ocular structures. Approximating the dynamic fluorescence by a double exponential function, the shortest lifetimes were detected in RPE and neuronal retina. The histograms of mean lifetime t M cover each other on lens with cornea and also on sclera with choroid. Despite the lifetimes are close between RPE and neuronal retina, the relative contributions Q I are wide different. The gradient of trend lines in cluster diagrams of amplitudes α II vs. α I allows a discrimination of ocular structures.
Bolch, W E; Dietze, G; Petoussi-Henss, N; Zankl, M
2015-06-01
Based upon recent epidemiological studies of ocular exposure, the Main Commission of the International Commission on Radiological Protection (ICRP) in ICRP Publication 118 states that the threshold dose for radiation-induced cataracts is now considered to be approximately 0.5 Gy for both acute and fractionated exposures. Consequently, a reduction was also recommended for the occupational annual equivalent dose to the lens of the eye from 150 mSv to 20 mSv, averaged over defined periods of 5 years. To support ocular dose assessment and optimisation, Committee 2 included Annex F within ICRP Publication 116 . Annex F provides dose coefficients - absorbed dose per particle fluence - for photon, electron, and neutron irradiation of the eye and lens of the eye using two dosimetric models. The first approach uses the reference adult male and female voxel phantoms of ICRP Publication 110. The second approach uses the stylised eye model of Behrens et al., which itself is based on ocular dimensional data given in Charles and Brown. This article will review the data and models of Annex F with particular emphasis on how these models treat tissue regions thought to be associated with stem cells at risk. © The International Society for Prosthetics and Orthotics Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
He, Jiangnan; Lu, Lina; He, Xiangui; Xu, Xian; Du, Xuan; Zhang, Bo; Zhao, Huijuan; Sha, Jida; Zhu, Jianfeng; Zou, Haidong; Xu, Xun
2017-01-01
To report calculated crystalline lens power and describe the distribution of ocular biometry and its association with refractive error in older Chinese adults. Random clustering sampling was used to identify adults aged 50 years and above in Xuhui and Baoshan districts of Shanghai. Refraction was determined by subjective refraction that achieved the best corrected vision based on monocular measurement. Ocular biometry was measured by IOL Master. The crystalline lens power of right eyes was calculated using modified Bennett-Rabbetts formula. We analyzed 6099 normal phakic right eyes. The mean crystalline lens power was 20.34 ± 2.24D (range: 13.40-36.08). Lens power, spherical equivalent, and anterior chamber depth changed linearly with age; however, axial length, corneal power and AL/CR ratio did not vary with age. The overall prevalence of hyperopia, myopia, and high myopia was 48.48% (95% CI: 47.23%-49.74%), 22.82% (95% CI: 21.77%-23.88%), and 4.57% (95% CI: 4.05-5.10), respectively. The prevalence of hyperopia increased linearly with age while lens power decreased with age. In multivariate models, refractive error was strongly correlated with axial length, lens power, corneal power, and anterior chamber depth; refractive error was slightly correlated with best corrected visual acuity, age and sex. Lens power, hyperopia, and spherical equivalent changed linearly with age; Moreover, the continuous loss of lens power produced hyperopic shifts in refraction in subjects aged more than 50 years.
Gross, Janine; Wegener, Alfred R; Kronschlaeger, Martin; Holz, Frank G; Schönfeld, Carl-Ludwig; Meyer, Linda M
2018-04-26
The purpose of this study was to investigate the neurokinin receptor-1 (NKR-1) protein expression in ocular tissues before and after supra-cataract threshold ultraviolet radiation (UVR-B peak at 312 nm) exposure in vivo in a mouse model. Six-week-old C57Bl/6 mice were unilaterally exposed to a single (2.9 kJ/m 2 ) and an above 3-fold UVR-B cataract threshold dose (9.4 kJ/m 2 ) of UVR. UVR-exposure (λpeak = 312 nm) was performed in mydriasis using a Bio-Spectra exposure system. After latency periods of 3 and 7 days, eyes were fixed in 4% paraformaldehyde, embedded in paraffin, sectioned and stained with fluorescence coupled antibody for NKR-1 and DAPI for cell nuclei staining. Control animals received only anesthesia but no UVR-exposure. Cataract development was documented with a Leica dark-field microscope and quantified as integrated optical density (IOD). NKR-1 is ubiquitously present in ocular tissues. An above 3-fold cataract threshold dose of UV-radiation induced NKR-1 upregulation after days 3 and 7 in the epithelium and endothelium of the cornea, the endothelial cells of the iris vessels, the pigmented epithelium/stroma of the ciliary body, the lens epithelium, pronounced in the nuclear bow region and the inner plexiform layer of the retina. A significant upregulation of NKR-1 could not be provoked with a single cataract threshold dose (2.9 kJ/m 2 UVR-B) ultraviolet irradiation. All exposed eyes developed anterior subcapsular cataracts. Neurokinin-1 receptor is present ubiquitously in ocular tissues including the lens epithelium and the nuclear bow region of the lens. UV-radiation exposure to an above 3-fold UVR-B cataract threshold dose triggers NKR-1 upregulation in the eye in vivo. The involvement of inflammation in ultraviolet radiation induced cataract and the role of neuroinflammatory peptides such as substance P and its receptor, NKR-1, might have been underestimated to date. Copyright © 2018. Published by Elsevier Ltd.
Dogru, Murat; Ward, Samantha K; Wakamatsu, Tais; Ibrahim, Osama; Schnider, Cristina; Kojima, Takashi; Matsumoto, Yukihiro; Ogawa, Junko; Shimazaki, Jun; Tsubota, Kazuo
2011-04-01
To prospectively investigate the effects of 2 week senofilcon A contact lens (CL) daily wear on the functional visual acuity (VA), ocular surface and tear film. Seventeen right eyes of 17 senofilcon A CL wearers without any ocular or systemic diseases were examined before and 2 weeks after lens wear. Visual acuity measurements, tear evaporation rate, ELISA for tear cytokines, strip meniscometry, tear lipid layer interferometry, tear film break-up time (BUT), in vivo confocal microscopy, corneal sensitivity, ocular surface vital staining, Schirmer I test and brush cytology for MUC5AC mRNA expression were performed before and after CL wear. The best corrected Landolt VA, functional VA parameters, the mean lipid layer interferometry grades, tear evaporation rates, Schirmer test values, vital staining scores and in vivo confocal microscopy parameters did not show any significant differences after 2 weeks of CL wear. The tear film BUT showed a significant decrease together with a significant down regulation of MUC5 AC mRNA expression after CL wear. A statistically significant elevation in the mean tear interleukin (IL)-6 concentration was also observed after 2 weeks of CL wear. Two week senofilcon A daily CL wear seems to be associated with tear instability, a decrease in MUC5AC expression, and elevation of IL-6 in tears without significant alterations in epithelial damage scores or in the morphology or density of in vivo keratoconjunctival cells and nerves. Alterations associated with long term wear and patients with dry eye disease need to be studied in future trials. Copyright © 2010 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
Sarac, Ozge; Gurdal, Canan; Bostancı-Ceran, Basak; Can, Izzet
2012-06-01
The aim of this study was to evaluate tear osmolarity and ocular comfort with two different types of hydrogel daily disposable lenses. The right eyes of 15 first-time contact lens users were included in this prospective study. All eyes wore hilafilcon B silicone hydrogel contact lenses for 8 h (group 1). After 1 week without contact lenses, all eyes wore narafilcon A silicone hydrogel contact lenses for 8 h (group 2). Tear osmolarity measurement was performed before and after 4 and 8 h of each contact lens wear. Ocular comfort was assessed after 4 and 8 h of each contact lens wear. In group 1, the mean baseline, 4- and 8-h tear osmolarity values were 293 ± 10.57, 303.00 ± 10.5 mOsm/L (p = 0.023), and 295.0 ± 1.4 mOsm/L (p > 0.05), respectively. In group 2, the mean baseline, 4- and 8-h tear osmolarity values were 294 ± 13.65, 300.9 ± 11.3 mOsm/L (p = 0.007), and 298.80 ± 7.2 mOsm/L (p > 0.05), respectively. In group 1, the mean comfort score was 7.20 ± 0.45 and 8.60 ± 0.45 at 4 and 8 h, respectively (p = 0.038). In group 2, the mean comfort score significantly decreased from 9.80 ± 0.45 to 7.80 ± 0.84 at 4 h (p = 0.039). Both hydrogel and silicone hydrogel daily disposable contact lenses elevated tear osmolarity during 8 h of contact lens wear. The increase in tear osmolarity with both contact lenses was below the cut-off value for dry eye and was not associated with ocular comfort.
E. Bowrey, Hannah; Zeng, Guang; Y. Tse, Dennis; J. Leotta, Amelia; Wu, Yi; To, Chi-Ho; F. Wildsoet, Christine; McFadden, Sally A.
2017-01-01
Purpose It has been proposed that the peripheral retina, responding to local optical defocus, contributes to myopia and associated altered eye growth in humans. To test this hypothesis, we measured the changes in central (on-axis) and peripheral ocular dimensions in guinea pigs wearing a concentric bifocal spectacle lens design with power restricted to the periphery. Methods Five groups of guinea pigs (n = 83) wore either a unifocal (UF) spectacle lens (−4, 0, or +4 Diopters [D]), or a peripheral defocus (PF) spectacle lens that had a plano center (diameter of 5 mm) with either −4 or +4 D in the surround (−4/0 or +4/0 D). The overall optical diameter of all lenses was 12 mm. Lenses were worn over one eye from 8 to 18 days of age for negative and plano lenses, or from 8 to 22 days of age for positive lenses. Refractive error was measured centrally and 30° off-axis in the temporal and nasal retina. The shape of the eye was analyzed from images of sectioned eyes. Results Lenses of −4 D UF induced myopia, reflecting enhanced ocular elongation, which was centered on the optic nerve head and included the surrounding peripapillary zone (PPZ, 18° in diameter). Some ocular expansion, including within the PPZ, also was recorded with −4/0 and +4/0 D PF lenses while the +4 D UF lens inhibited rather than enhanced elongation, centrally and peripherally. Conclusions Peripheral defocus-induced ocular expansion encompasses the PPZ, irrespective of the sign of the inducing defocus. Understanding the underlying mechanism potentially has important implications for designing multifocal lenses for controlling myopia in humans and also potentially for understanding the link between myopia and glaucoma. PMID:28549092
A Protective Eye Shield for Prevention of Media Opacities during Small Animal Ocular Imaging
Bell, Brent A.; Kaul, Charles; Hollyfield, Joe G.
2014-01-01
Optical coherence tomography (OCT), scanning laser ophthalmoscopy (SLO) and other non-invasive imaging techniques are increasingly used in eye research to document disease-related changes in rodent eyes. Corneal dehydration is a major contributor to the formation of ocular opacities that can limit the repeated application of these techniques to individual animals. General anesthesia is usually required for imaging, which is accompanied by the loss of the blink reflex. As a consequence, the tear film cannot be maintained, drying occurs and the cornea becomes dehydrated. Without supplemental hydration, structural damage to the cornea quickly follows. Soon thereafter, anterior lens opacities can also develop. Collectively these changes ultimately compromise image quality, especially for studies involving repeated use of the same animal over several weeks or months. To minimize these changes, a protective shield was designed for mice and rats that prevent ocular dehydration during anesthesia. The eye shield, along with a semi-viscous ophthalmic solution, is placed over the corneas as soon as the anesthesia immobilizes the animal. Eye shields are removed for only the brief periods required for imaging and then reapplied before the fellow eye is examined. As a result, the corneal surface of each eye is exposed only for the time required for imaging. The device and detailed methods described here minimize the corneal and lens changes associated with ocular surface desiccation. When these methods are used consistently, high quality images can be obtained repeatedly from individual animals. PMID:25245081
Hybrid-modality ocular imaging using a clinical ultrasound system and nanosecond pulsed laser.
Lim, Hoong-Ta; Matham, Murukeshan Vadakke
2015-07-01
Hybrid optical modality imaging is a special type of multimodality imaging significantly used in the recent past in order to harness the strengths of different imaging methods as well as to furnish complementary information beyond that provided by any individual method. We present a hybrid-modality imaging system based on a commercial clinical ultrasound imaging (USI) system using a linear array ultrasound transducer (UST) and a tunable nanosecond pulsed laser as the source. The integrated system uses photoacoustic imaging (PAI) and USI for ocular imaging to provide the complementary absorption and structural information of the eye. In this system, B-mode images from PAI and USI are acquired at 10 Hz and about 40 Hz, respectively. A linear array UST makes the system much faster compared to other ocular imaging systems using a single-element UST to form B-mode images. The results show that the proposed instrumentation is able to incorporate PAI and USI in a single setup. The feasibility and efficiency of this developed probe system was illustrated by using enucleated pig eyes as test samples. It was demonstrated that PAI could successfully capture photoacoustic signals from the iris, anterior lens surface, and posterior pole, while USI could accomplish the mapping of the eye to reveal the structures like the cornea, anterior chamber, lens, iris, and posterior pole. This system and the proposed methodology are expected to enable ocular disease diagnostic applications and can be used as a preclinical imaging system.
Sliney, David H
2002-01-01
The geographical variations in the incidence of age-related ocular changes such as presbyopia and cataracts and diseases such as pterygium and droplet keratopathies have led to theories pointing to sunlight, ultraviolet radiation (UVR) exposure and ambient temperature as potential etiological factors. Some epidemiological evidence also points to an association of age-related macular degeneration to sunlight exposure. The actual distribution of sunlight exposure and the determination of temperature variations of different tissues within the anterior segment of the eye are difficult to assess. Of greatest importance are the geometrical factors that influence selective UVR exposures to different segments of the lens, cornea and retina. Studies show that the temperature of the lens and cornea varies by several degrees depending upon climate, and that the incidence of nuclear cataract incidence is greater in areas of higher ambient temperature (i.e., in the tropics). Likewise, sunlight exposure to local areas of the cornea, lens and retina varies greatly in different environments. However, epidemiological studies of the influence of environmental UVR in the development of cataract, pterygium, droplet keratopathies and age-related macular degeneration have produced surprisingly inconsistent findings. The lack of consistent results is seen to be due largely to either incomplete or erroneous estimates of outdoor UV exposure dose. Geometrical factors dominate the determination of UVR exposure of the eye. The degree of lid opening limits ocular exposure to rays entering at angles near the horizon. Clouds redistribute overhead UVR to the horizon sky. Mountains, trees and building shield the eye from direct sky exposure. Most ground surfaces reflect little UVR. The result is that highest UVR exposure occurs during light overcast where the horizon is visible and ground surface reflection is high. By contrast, exposure in a high mountain valley (lower ambient temperature) with green foliage results in a much lower ocular dose. Other findings of these studies show that retinal exposure to light and UVR in daylight occurs largely in the superior retina.
Babizhayev, Mark A; Yegorov, Yegor E
2016-01-01
The aging eye appears to be at considerable risk from oxidative stress. A great deal of research indicates that dysfunctional mitochondria are the primary site of reactive oxygen species (ROS). More than 95% of O2 produced during normal metabolism is generated by the electron transport chain in the inner mitochondrial membrane. Mitochondria are also the major target of ROS. Cataract formation, the opacification of the eye lens, is one of the leading causes of human blindness worldwide, accounting for 47.8% of all causes of blindness. Cataracts result from the deposition of aggregated proteins in the eye lens and lens fiber cell plasma membrane damage, which causes clouding of the lens, light scattering, and obstruction of vision. ROS-induced damage in the lens cell may consist of oxidation of proteins, DNA damage, and/or lipid peroxidation, all of which have been implicated in cataractogenesis. This article is an attempt to integrate how mitochondrial ROS are altered in the aging eye along with those protective and repair therapeutic systems believed to regulate ROS levels in ocular tissues and how damage to these systems contributes to age-onset eye disease and cataract formation. Mitochondria-targeted antioxidants might be used to effectively prevent ROS-induced oxidation of lipids and proteins in the inner mitochondrial membrane in vivo. As a result of the combination of weak metal chelating, OH and lipid peroxyl radicals scavenging, reducing activities to liberated fatty acid, and phospholipid hydroperoxides, carnosine and carcinine appear to be physiological antioxidants able to efficiently protect the lipid phase of biologic membranes and aqueous environments and act as the antiapoptotic natural drug compounds The authors developed and patented the new ophthalmic compositions, including N-acetylcarnosine, acting as a prodrug of naturally targeted to mitochondria L-carnosine endowed with pluripotent antioxidant activities combined with mitochondria-targeted rechargeable antioxidant (either MitoVit E, Mito Q, or SkQs) as a potent medicine to treat ocular diseases. Such specificity is explained by the fact that developed compositions might be used to effectively prevent ROS-induced oxidation of lipids and proteins in the inner mitochondrial membrane in vivo and outside mitochondria in the cellular and tissue structures of the lens and eye compartments. Mitochondrial targeting of compounds with universal types of antioxidant activity represents a promising approach for treating a number of ROS-related ocular diseases of the aging eye and can be implicated in the management of cataracts.
Cone signals for spectacle-lens compensation: differential responses to short and long wavelengths.
Rucker, Frances J; Wallman, Josh
2008-09-01
Chick eyes compensate for defocus imposed by spectacle lenses by making compensatory changes in eye length and choroidal thickness, a laboratory model of emmetropization. To investigate the roles of longitudinal chromatic aberration and of chromatic mechanisms in emmetropization, we examined the participation of different cone classes, and we compared the efficacy of lens compensation under monochromatic illumination with that under white light of the same illuminance to the chick eye. Chicks wore positive or negative 6D or 8D lenses on one eye for 3 days, under either blue (460 nm) or red (620 nm) light at 0.67 lux or under white light at 0.67 or 0.2 lux (all measures are corrected for chick photopic sensitivity). The illumination conditions were chosen to differentially stimulate either the short-wavelength and ultraviolet cones or the long-wavelength and double cones. Measurements are expressed as the relative change: the inter-ocular difference in the amount of change over the 3 days of lens wear. We find that under this low illumination the two components of lens compensation were differentially affected by the monochromatic illumination: in blue light lens compensation was mainly due to changes in eye length, whereas in red light lens compensation was mainly due to changes in choroidal thickness. In general, white light produced better lens compensation than monochromatic illumination. NEGATIVE LENSES: Under white light negative lenses caused an increase in eye length (60 microm) together with a decrease in choroidal thickness (-51 microm) relative to the fellow eye. Under blue light, although there was an increase in eye length (32 microm), there was no change in choroidal thickness (5 microm). In contrast, under red light there was a decrease in choroidal thickness (-62 microm) but no increase in eye length (8 microm). Relative ocular elongation was the same in white and monochromatic light. POSITIVE LENSES: Under white light positive lenses caused a decrease in eye length (-142 microm) together with an increase in choroidal thickness (68 microm) relative to the fellow eye. Under blue light, there was a decrease in eye length (-64 microm), but no change in choroidal thickness (2 microm). In contrast, under red light there was an increase (90 microm) in choroidal thickness but less of a decrease (-36 microm) in eye length. Lens compensation by inhibition of ocular elongation was less effective under monochromatic illumination than under white light (white v red: p=0.003; white v blue p=.014). The differential effects of red and blue light on the choroidal and ocular length compensatory responses suggest that they are driven by different proportions of the cone-types, implying that, although chromatic contrast is not essential for lens compensation and presumably for emmetropization as well, the retinal substrates exist for utilizing chromatic contrast in these compensatory responses. The generally better lens compensation in white than monochromatic illumination suggests that longitudinal chromatic aberration may be used in lens compensation.
Curvularia lunata endophthalmitis.
Berbel, Rodrigo Fabri; Casella, Antonio Marcelo Barbante; de Freitas, Denise; Höfling-Lima, Ana Luisa
2011-10-01
The aim of this study was to report a case of a 52-year-old man with a rare fungal endophthalmitis after penetrating ocular trauma with a fish hook. The patient was submitted to wound repair and hook extraction. Three weeks after the trauma, a cataract extraction with phacoemulsification and in-the-bag intraocular lens implantation was performed. After the development of endophthalmitis, vitrectomy and lens explantation with positive culture for Curvularia lunata were carried out. The infection was controlled with the administration of systemic itraconazole and intraocular voriconazole. The use of intravitreal voriconazole injection is a viable option in cases of Curvularia fungal endophthalmitis.
Complete 360° circumferential SSOCT gonioscopy of the iridocorneal angle
NASA Astrophysics Data System (ADS)
McNabb, Ryan P.; Kuo, Anthony N.; Izatt, Joseph A.
2014-02-01
The ocular iridocorneal angle is generally an optically inaccessible area when viewed directly through the cornea due to the high angle of incidence required and the large index of refraction difference between air and cornea (nair = 1.000 and ncornea = 1.376) resulting in total internal reflection. Gonioscopy allows for viewing of the angle by removing the aircornea interface through the use of a special contact lens on the eye. Gonioscopy is used clinically to visualize the angle directly but only en face. Optical coherence tomography (OCT) has been used to image the angle and deeper structures via an external approach. Typically, this imaging technique is performed by utilizing a conventional anterior segment OCT scanning system. However, instead of imaging the apex of the cornea, either the scanner or the subject is tilted such that the corneoscleral limbus is orthogonal to the optical axis of the scanner requiring multiple volumes to obtain complete circumferential coverage of the ocular angle. We developed a novel gonioscopic OCT (GOCT) system that images the entire ocular angle within a single volume via an "internal" approach through the use of a custom radially symmetric gonioscopic contact lens. We present, to our knowledge, the first complete 360° circumferential volumes of the iridocorneal angle from a direct, internal approach.
Temporal integration of visual signals in lens compensation (a review)
Zhu, Xiaoying
2013-01-01
Postnatal eye growth is controlled by visual signals. When wearing a positive lens that causes images to be focused in front of the retina (myopic defocus), the eye reduces its rate of ocular elongation and increases choroidal thickness to move the retina forward to meet the focal plane of the eye. When wearing a negative lens that causes images to be focused behind the retina (hyperopic defocus), the opposite happens. This review summarizes how the retina integrates the constantly changing visual signals in a non-linear fashion to guide eye growth in chicks: (1a) When myopic or hyperopic defocus is interrupted by a daily episode of normal vision, normal vision is more effective in reducing myopia caused by hyperopic defocus than in reducing hyperopia caused by myopic defocus; (1b) when the eye experiences alternating myopic and hyperopic defocus, the eye is more sensitive to myopic defocus than to hyperopic defocus and tends to develop hyperopia, even if the duration of hyperopic defocus is much longer than the duration of myopic defocus; (2) when the eye experiences brief, repeated episodes of defocus by wearing either positive or negative lenses, lens compensation depends on the frequency and duration of individual episodes of lens wear, not just the total daily duration of lens wear; and (3) further analysis of the time constants for the hypothesized internal emmetropization signals show that, while it takes approximately the same amount of time for the signals to rise and saturate during lens-wearing episodes, the decline of the signals between episodes depends strongly on the sign of defocus and the ocular component. Although most extensively studied in chicks, the nonlinear temporal integration of visual signals has been found in other animal models. These findings may help explain the complex etiology of myopia in school-aged children and suggest ways to slow down myopia progression. PMID:23470505
Temporal integration of visual signals in lens compensation (a review).
Zhu, Xiaoying
2013-09-01
Postnatal eye growth is controlled by visual signals. When wearing a positive lens that causes images to be focused in front of the retina (myopic defocus), the eye reduces its rate of ocular elongation and increases choroidal thickness to move the retina forward to meet the focal plane of the eye. When wearing a negative lens that causes images to be focused behind the retina (hyperopic defocus), the opposite happens. This review summarizes how the retina integrates the constantly changing visual signals in a non-linear fashion to guide eye growth in chicks: (1a) When myopic or hyperopic defocus is interrupted by a daily episode of normal vision, normal vision is more effective in reducing myopia caused by hyperopic defocus than in reducing hyperopia caused by myopic defocus; (1b) when the eye experiences alternating myopic and hyperopic defocus, the eye is more sensitive to myopic defocus than to hyperopic defocus and tends to develop hyperopia, even if the duration of hyperopic defocus is much longer than the duration of myopic defocus; (2) when the eye experiences brief, repeated episodes of defocus by wearing either positive or negative lenses, lens compensation depends on the frequency and duration of individual episodes of lens wear, not just the total daily duration of lens wear; and (3) further analysis of the time constants for the hypothesized internal emmetropization signals show that, while it takes approximately the same amount of time for the signals to rise and saturate during lens-wearing episodes, the decline of the signals between episodes depends strongly on the sign of defocus and the ocular component. Although most extensively studied in chicks, the nonlinear temporal integration of visual signals has been found in other animal models. These findings may help explain the complex etiology of myopia in school-aged children and suggest ways to slow down myopia progression. Copyright © 2013 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lesperance, Marielle; Inglis-Whalen, M.; Thomson, R. M., E-mail: rthomson@physics.carleton.ca
Purpose : To investigate the effects of the composition and geometry of ocular media and tissues surrounding the eye on dose distributions for COMS eye plaque brachytherapy with{sup 125}I, {sup 103}Pd, or {sup 131}Cs seeds, and to investigate doses to ocular structures. Methods : An anatomically and compositionally realistic voxelized eye model with a medial tumor is developed based on a literature review. Mass energy absorption and attenuation coefficients for ocular media are calculated. Radiation transport and dose deposition are simulated using the EGSnrc Monte Carlo user-code BrachyDose for a fully loaded COMS eye plaque within a water phantom andmore » our full eye model for the three radionuclides. A TG-43 simulation with the same seed configuration in a water phantom neglecting the plaque and interseed effects is also performed. The impact on dose distributions of varying tumor position, as well as tumor and surrounding tissue media is investigated. Each simulation and radionuclide is compared using isodose contours, dose volume histograms for the lens and tumor, maximum, minimum, and average doses to structures of interest, and doses to voxels of interest within the eye. Results : Mass energy absorption and attenuation coefficients of the ocular media differ from those of water by as much as 12% within the 20–30 keV photon energy range. For all radionuclides studied, average doses to the tumor and lens regions in the full eye model differ from those for the plaque in water by 8%–10% and 13%–14%, respectively; the average doses to the tumor and lens regions differ between the full eye model and the TG-43 simulation by 2%–17% and 29%–34%, respectively. Replacing the surrounding tissues in the eye model with water increases the maximum and average doses to the lens by 2% and 3%, respectively. Substituting the tumor medium in the eye model for water, soft tissue, or an alternate melanoma composition affects tumor dose compared to the default eye model simulation by up to 16%. In the full eye model simulations, the average dose to the lens is larger by 7%–9% than the dose to the center of the lens, and the maximum dose to the optic nerve is 17%–22% higher than the dose to the optic disk for all radionuclides. In general, when normalized to the same prescription dose at the tumor apex, doses delivered to all structures of interest in the full eye model are lowest for{sup 103}Pd and highest for {sup 131}Cs, except for the tumor where the average dose is highest for {sup 103}Pd and lowest for {sup 131}Cs. Conclusions : The eye is not radiologically water-equivalent, as doses from simulations of the plaque in the full eye model differ considerably from doses for the plaque in a water phantom and from simulated TG-43 calculated doses. This demonstrates the importance of model-based dose calculations for eye plaque brachytherapy, for which accurate elemental compositions of ocular media are necessary.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lesperance, Marielle; Inglis-Whalen, M.; Thomson, R. M., E-mail: rthomson@physics.carleton.ca
Purpose : To investigate the effects of the composition and geometry of ocular media and tissues surrounding the eye on dose distributions for COMS eye plaque brachytherapy with{sup 125}I, {sup 103}Pd, or {sup 131}Cs seeds, and to investigate doses to ocular structures. Methods : An anatomically and compositionally realistic voxelized eye model with a medial tumor is developed based on a literature review. Mass energy absorption and attenuation coefficients for ocular media are calculated. Radiation transport and dose deposition are simulated using the EGSnrc Monte Carlo user-code BrachyDose for a fully loaded COMS eye plaque within a water phantom andmore » our full eye model for the three radionuclides. A TG-43 simulation with the same seed configuration in a water phantom neglecting the plaque and interseed effects is also performed. The impact on dose distributions of varying tumor position, as well as tumor and surrounding tissue media is investigated. Each simulation and radionuclide is compared using isodose contours, dose volume histograms for the lens and tumor, maximum, minimum, and average doses to structures of interest, and doses to voxels of interest within the eye. Results : Mass energy absorption and attenuation coefficients of the ocular media differ from those of water by as much as 12% within the 20–30 keV photon energy range. For all radionuclides studied, average doses to the tumor and lens regions in the full eye model differ from those for the plaque in water by 8%–10% and 13%–14%, respectively; the average doses to the tumor and lens regions differ between the full eye model and the TG-43 simulation by 2%–17% and 29%–34%, respectively. Replacing the surrounding tissues in the eye model with water increases the maximum and average doses to the lens by 2% and 3%, respectively. Substituting the tumor medium in the eye model for water, soft tissue, or an alternate melanoma composition affects tumor dose compared to the default eye model simulation by up to 16%. In the full eye model simulations, the average dose to the lens is larger by 7%–9% than the dose to the center of the lens, and the maximum dose to the optic nerve is 17%–22% higher than the dose to the optic disk for all radionuclides. In general, when normalized to the same prescription dose at the tumor apex, doses delivered to all structures of interest in the full eye model are lowest for{sup 103}Pd and highest for {sup 131}Cs, except for the tumor where the average dose is highest for {sup 103}Pd and lowest for {sup 131}Cs. Conclusions : The eye is not radiologically water-equivalent, as doses from simulations of the plaque in the full eye model differ considerably from doses for the plaque in a water phantom and from simulated TG-43 calculated doses. This demonstrates the importance of model-based dose calculations for eye plaque brachytherapy, for which accurate elemental compositions of ocular media are necessary.« less
Density of the crystalline lens in obese and nonobese children.
Acer, Semra; Ağladıoğlu, Sebahat Yılmaz; Pekel, Gökhan; Özhan, Bayram; Çetin, Ebru Nevin; Yağcı, Ramazan; Yıldırım, Cem
2016-02-01
To compare crystalline lens density in obese and nonobese children. A total of 40 obese (25 females) and 46 age-sex matched controls (26 females) were included in this prospective study. Children with ocular diseases (except for mild refractive errors), ocular trauma, or surgery and any systemic disorders, including diabetes, were excluded. Lens densitometry (LD), central corneal thickness (CCT), anterior chamber depth (ACD) and corneal volume (CV) were measured by Pentacam HR. Mean participant age was 12.0 ± 1.9 (range, 7.2-18 years) in the obese group and 11.7 ± 2.0 (range, 7.5-16.1 years) in the control group. The BMI was 29.9 ± 4.5 in the obese group and 18.7 ± 2.5 in the control group (P ≤ 0.05). The vertical, horizontal, and areal lens density measurements were higher in obese group than in controls (P ≤ 0.05). There was a positive correlation between BMI and vertical, horizontal, and areal lens density measurements. The difference in CCT, ACD, and CV was not statistically significant between groups (P ≥ 0.05). There is increased lens density in the obese children compared with controls. Pentacam HR may provide objective data about lens density in children. Copyright © 2016 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.
Identification and enumeration of staphylococci from the eye during soft contact lens wear.
Leitch, E C; Harmis, N Y; Corrigan, K M; Willcox, M D
1998-04-01
An extensive study was conducted to identify and enumerate staphylococcal microbiota found on ocular sites during asymptomatic soft contact lens (SCL) wear. A biochemical identification system separately grouped the eight clinically relevant staphylococci. Total counts and isolation frequencies from SCLs and ocular sites were evaluated. The epidermidis group was the most numerous isolate from extended wear (EW) lenses; the capitis/warneri group was the most numerous (p < 0.05) from daily wear (DW) lenses. In both DW and EW, the greatest isolation frequency (p < 0.05) was recorded for the capitis/warneri group. The remaining six groups were isolated infrequently and in low numbers. These results show that, in addition to Staphylococcus epidermidis, other staphylococcal species may be important members of the normal microbiota of the ocular surface during SCL wear. Furthermore, an increase and a shift in staphylococcal microbiota between DW and EW regimes was highlighted.
Topical nutraceutical Optixcare EH ameliorates experimental ocular oxidative stress in rats.
Kador, Peter F; Guo, Changmei; Kawada, Hiroyoshi; Randazzo, James; Blessing, Karen
2014-09-01
Based on the hypothesis that oral nutraceuticals do not adequately reach all ocular tissues in the anterior segment, we evaluated the ability of a 3% concentration of the ingredients in a topical nutraceutical antioxidant formulation called Optixcare Eye Health (Optixcare EH) to ameliorate oxidative stress in rat models of age-related ocular diseases. Diabetes was induced by tail-vein injection of streptozotocin, and the development of cataracts was monitored by slit lamp. Young rats were exposed to ultraviolet (UV) light, and the reduction in lens glutathione (GSH) levels and increase in 4-hydroxynonenol (4-HNE) were measured. Oxidative stress in the neural retina was generated by exposure of dark-adapted rats to 1,000 lx of light, and oxidative stress markers were measured. Dry eye was induced in rats by twice daily (b.i.d.) subcutaneous scopolamine injections. Topical Optixcare EH was administered b.i.d. and compared in select experiments to the multifunctional antioxidant JHX-4, the topical aldose reductase inhibitor (ARI) Kinostat™, oral Ocu-GLO™, and the topical ocular comfort agents Optixcare Eye Lube, Optixcare Eye Lube + Hyaluron, and Idrop Vet Plus hyaluronic acid. In diabetic rats, topical ARI treatment prevented cataract formation while the nutraceuticals delayed their development with Optixcare EH>Ocu-GLO. In UV-exposed rats, the reduction of GSH and increase in 4-HNE in the lens were normalized in order JHX-4>Optixcare EH>Ocu-GLO. In the retina, oxidative stress markers were reduced better by oral JHX-4 compared with topical Optixcare EH. In the scopolamine-induced dry-eye rats, tear flow was maintained by Optixcare EH treatment, while none of the comfort agents examined altered tear flow. Topical administration of a 3% concentration of the ingredients in Optixcare EH reduces experimentally induced reactive oxygen species in rats exposed to several sources of ocular oxidative stress. In addition, Optixcare EH maintains tear volume in scopolamine-induced dry eye. This suggests that in the anterior segment, the ingredients in Optixcare EH may have clinical potential against ocular oxidative stress.
Oral omega-6 essential fatty acid treatment in contact lens associated dry eye.
Kokke, Karolien H; Morris, Judith A; Lawrenson, John G
2008-06-01
Symptoms of dry eye are commonly reported in contact lens wearers and are a frequent cause of non-tolerance. The purpose of the present study is to evaluate the effects of oral treatment with particular omega-6 fatty acids in the form of evening primrose oil (EPO) on subjective symptoms, ocular surface signs and tear film characteristic in patients with contact lens associated dry eye. The study design was randomised, double-masked and placebo controlled. 76 female soft contact lens wearers were treated for 6 months with either EPO or placebo (olive oil). Subjects underwent three examinations (baseline, 3 and 6 months). At each examination subjects were given a questionnaire relating to lens comfort and dry eye symptoms and underwent a series of tests of tear film characteristics (tear meniscus height, break-up time), meibomian gland function (lipid layer thickness and quality) and ocular surface parameters (hyperaemia and staining). The EPO group showed a significant improvement in the specific symptom of 'dryness' at 3 and 6 months (p<0.01) and also a significant improvement in overall lens comfort at 6 months (p<0.01). Tear meniscus height was increased in the EPO group at 6 months relative to baseline (p<0.01), although all other objective signs were unchanged. This study provides evidence for a beneficial effect of particular orally administered omega-6 fatty acids in alleviating dry eye symptoms and improving overall lens comfort in patients suffering from contact lens associated dry eye.
On-eye breakage and recovery of mini-scleral contact lens without compromise for the ocular surface.
Macedo-de-Araújo, Rute J; van der Worp, Eef; González-Méijome, José M
2018-06-01
To report the on-eye breakage of a mini-scleral contact lens in a healthy cornea after being hit by a speeding object, without causing any severe corneal damage. A 24-year-old Caucasian male involved in a clinical study reported the in situ breakage of a mini-scleral contact lens during motorbike maintenance. The patient reported eye redness and irritation that significantly decreased after all the pieces of the lens were recovered from the eye. Ocular examinations within 48 h showed absence of corneal damage other than superficial punctate keratitis inferiorly and no fragments of the lens were found in the conjunctival sac. The patient was wearing a 15.2 mm mini-scleral lens in a high Dk material. The evolution of rigid materials towards higher Dk values has resulted in a decreased hardness and modulus values, so these materials are more elastic when subjected to mechanical stress, which could be a beneficial aspect in absorbing the energy of an impact before breaking in pieces. This case report shows that ScCL could have a protective effect to the corneal surface from the direct impact of a high-speed object. Mechanical material properties, wide supporting area and post-lens tear volume acted as protective factors helping to absorb and distribute the kinetic energy of the impacting object. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
Methyl trypsin loaded poly(D,L-lactide-coglycolide) nanoparticles for contact lens care.
Jimenez, N; Galan, J; Vallet, A; Egea, M A; Garcia, M L
2010-03-01
The need of an enzymatic cleaner for soft contact lens care with an improved ocular safety and stability profile led us to evaluate the use of nanoparticles (NPs) of poly(D,L-lactide-coglycolide) (PLGA) and methyl trypsin (MT). NPs were prepared by double emulsion-solvent evaporation technique. A factorial design was performed to select the lactic acid proportion in the copolymer and conditions of the second sonication. The increment in proportion of lactic acid provided higher particle size results. When the time of second sonication was decreased, the entrapment efficiency (EE) increased. PLGA 50:50 NPs were chosen for further development since PLGA 50:50H NPs settled fast with different particle size in the sediment and PLGA 75:25 NPs led to form aggregates. The addition of glycerol to the NPs provided the highest EE of MT (>90%) while the addition of Tetronic 1304 promoted the fast release of enzyme initially and decreased the zeta potential (zeta) up to neutral values after gamma irradiation. NPs are expected to be effective as a lens care cleaner after 3 days or even longer with a very low quantity of enzyme released. Formulations showed an acceptable irritation ocular tolerance after in vitro HET-CAM test and in vivo Draize test. 2009 Wiley-Liss, Inc. and the American Pharmacists Association
Contact Lens-Induced Discomfort and Protein Changes in Tears.
Masoudi, Simin; Stapleton, Fiona Jane; Willcox, Mark Duncan Perry
2016-08-01
Ocular discomfort is among the main causes of contact lens wear discontinuation. This study investigated the association between subjective ocular comfort ratings and diurnal changes in tear protein concentrations with and without contact lens wear. The study was a prospective, open-label, single-group two-staged investigation. Basal tears were collected from 30 experienced contact lens wearers twice a day (morning and evening) using a noninvasive method without lens wear (stage 1) and during wear of Etafilcon A contact lenses (stage 2) for 7 to 10 days. Subjects rated their ocular comfort on a scale of 1 to 100 (with 100 as extremely comfortable) at each time of tear collection. Tears were analyzed using liquid quadrupole mass spectrometry in conjunction with selected reaction monitoring (SRM) method. End-of-day comfort was reduced when wearing lenses (87.8 ± 14.3 AM vs. 79.2 ± 16.6 PM) compared to no lens wear (88.3 ± 12.6 AM vs. 84.7 ± 13.3 PM) (AM vs. PM, p < 0.05). A greater reduction in comfort over the day was seen during lens wear (p < 0.01). The concentration of prolactin-induced protein increased from morning to evening in both stages (mean ± SD; 0.08 ± 0.04 mg/ml, AM vs. 0.09 ± 0.05 mg/ml, PM, p < 0.05). There was no change in the concentration of lactoferrin (1.20 ± 0.77 mg/ml), lysozyme (2.11 ± 1.50 mg/ml), lipocalin 1 (1.75 ± 0.99 mg/ml), or proline-rich protein 4 (0.80 ± 0.49 mg/ml). The prolactin-induced protein concentration was negatively associated with discomfort levels in tears (p < 0.05, r = -0.29). Only the absolute concentration of prolactin-induced protein correlated with subjective comfort ratings. Taking into consideration that prolactin-induced protein can be associated with disruption in water transport in lacrimal glands, our findings may indicate that changes to aqueous secretion are associated with contact lens discomfort.
Murphy, Patricia; Kabir, Md Humayun; Srivastava, Tarini; Mason, Michele E.; Dewi, Chitra U.; Lim, Seakcheng; Yang, Andrian; Djordjevic, Djordje; Killingsworth, Murray C.; Ho, Joshua W. K.; Harman, David G.
2018-01-01
ABSTRACT Cataracts cause vision loss and blindness by impairing the ability of the ocular lens to focus light onto the retina. Various cataract risk factors have been identified, including drug treatments, age, smoking and diabetes. However, the molecular events responsible for these different forms of cataract are ill-defined, and the advent of modern cataract surgery in the 1960s virtually eliminated access to human lenses for research. Here, we demonstrate large-scale production of light-focusing human micro-lenses from spheroidal masses of human lens epithelial cells purified from differentiating pluripotent stem cells. The purified lens cells and micro-lenses display similar morphology, cellular arrangement, mRNA expression and protein expression to human lens cells and lenses. Exposing the micro-lenses to the emergent cystic fibrosis drug Vx-770 reduces micro-lens transparency and focusing ability. These human micro-lenses provide a powerful and large-scale platform for defining molecular disease mechanisms caused by cataract risk factors, for anti-cataract drug screening and for clinically relevant toxicity assays. PMID:29217756
Murphy, Patricia; Kabir, Md Humayun; Srivastava, Tarini; Mason, Michele E; Dewi, Chitra U; Lim, Seakcheng; Yang, Andrian; Djordjevic, Djordje; Killingsworth, Murray C; Ho, Joshua W K; Harman, David G; O'Connor, Michael D
2018-01-09
Cataracts cause vision loss and blindness by impairing the ability of the ocular lens to focus light onto the retina. Various cataract risk factors have been identified, including drug treatments, age, smoking and diabetes. However, the molecular events responsible for these different forms of cataract are ill-defined, and the advent of modern cataract surgery in the 1960s virtually eliminated access to human lenses for research. Here, we demonstrate large-scale production of light-focusing human micro-lenses from spheroidal masses of human lens epithelial cells purified from differentiating pluripotent stem cells. The purified lens cells and micro-lenses display similar morphology, cellular arrangement, mRNA expression and protein expression to human lens cells and lenses. Exposing the micro-lenses to the emergent cystic fibrosis drug Vx-770 reduces micro-lens transparency and focusing ability. These human micro-lenses provide a powerful and large-scale platform for defining molecular disease mechanisms caused by cataract risk factors, for anti-cataract drug screening and for clinically relevant toxicity assays. © 2018. Published by The Company of Biologists Ltd.
Emmetropization and Eye Growth in Young Aphakic Chickens
Ai, Likun; Li, Jing; Guan, Huan; Wildsoet, Christine F.
2009-01-01
Purpose To establish a chick model to investigate the trends of eye growth and emmetropization after early lensectomy for congenital cataract. Methods Four monocular treatments were applied: lens extraction (LX); sham surgery/-30 D lens; LX/+20 D lens; and LX/+30-D lens (nine per group). Lens powers were selected to slightly undercorrect or overcorrect the induced hyperopia in LX eyes and to induce comparable hyperopia in sham-surgery eyes. Refractive errors and axial ocular dimensions were measured over a 28-day period. External ocular dimensions were obtained when the eyes were enucleated on the last day. Results The growth patterns of experimental (Exp) eyes varied with the type of manipulation. All eyes experiencing hyperopia initially grew more than their fellow eyes and exhibited myopic shifts in refraction. The sham/-30 D lens group showed the greatest increase in optical axial length, followed by the LX group, and then the LX/+20 D lens group. The Exp eyes of the LX/+30 D lens group, which were initially slightly myopic, grew least, and showed a small hyperopic shift. Lensectomized eyes enlarged more equatorially than axially (i.e., oblate), irrespective of the optical treatment applied. Conclusions The refractive changes observed in young, aphakic eyes are consistent with compensation for the defocus experienced, and thus emmetropization. However, differences in the effects of lensectomy compared to those of sham surgery raise the possibility that the lens is a source of essential growth factors. Alterative optical and mechanical explanations are offered for the oblate shapes of aphakic eyes. PMID:18719085
He, Jiangnan; Lu, Lina; He, Xiangui; Xu, Xian; Du, Xuan; Zhang, Bo; Zhao, Huijuan; Sha, Jida; Zhu, Jianfeng; Zou, Haidong; Xu, Xun
2017-01-01
Purpose To report calculated crystalline lens power and describe the distribution of ocular biometry and its association with refractive error in older Chinese adults. Methods Random clustering sampling was used to identify adults aged 50 years and above in Xuhui and Baoshan districts of Shanghai. Refraction was determined by subjective refraction that achieved the best corrected vision based on monocular measurement. Ocular biometry was measured by IOL Master. The crystalline lens power of right eyes was calculated using modified Bennett-Rabbetts formula. Results We analyzed 6099 normal phakic right eyes. The mean crystalline lens power was 20.34 ± 2.24D (range: 13.40–36.08). Lens power, spherical equivalent, and anterior chamber depth changed linearly with age; however, axial length, corneal power and AL/CR ratio did not vary with age. The overall prevalence of hyperopia, myopia, and high myopia was 48.48% (95% CI: 47.23%–49.74%), 22.82% (95% CI: 21.77%–23.88%), and 4.57% (95% CI: 4.05–5.10), respectively. The prevalence of hyperopia increased linearly with age while lens power decreased with age. In multivariate models, refractive error was strongly correlated with axial length, lens power, corneal power, and anterior chamber depth; refractive error was slightly correlated with best corrected visual acuity, age and sex. Conclusion Lens power, hyperopia, and spherical equivalent changed linearly with age; Moreover, the continuous loss of lens power produced hyperopic shifts in refraction in subjects aged more than 50 years. PMID:28114313
Maïssa, Cécile; Guillon, Michel; Garofalo, Renee J
2012-01-01
The principal objective of the study was to measure the conjunctival staining produced in the circumlimbal region by silicone hydrogel contact lenses with different edge designs. The secondary objective was to investigate the association between circumlimbal staining and comfort. Four silicone hydrogel contact lenses: ACUVUE OASYS (knife edge design), AIR OPTIX, Biofinity (chisel edge rounded edge combination), and PureVision (rounded edge design), and 1 hydrogel contact lens, ACUVUE 2 (knife edge design), were tested. The study was conducted on a cohort population of 27 established soft contact lens wearers, who wore each contact lens type, in a random order, for a period of 10 (±2) days. Circumlimbal staining was measured in a double-masked fashion through image analysis of digital photographs of lissamine green taken under controlled experimental conditions. The results obtained showed that contact lens edge design was the primary factor controlling circumlimbal staining for silicone hydrogel lenses: a rounded edge away from the ocular surface produced the lowest staining (average, 0.19%) and a knife edge in close apposition to the ocular surface produced the highest staining (average, 1.34%). Contact lens material rigidity was also identified to affect circumlimbal staining and an inverse association between circumlimbal staining and contact lens comfort was demonstrated: the rounded edge design produced the lowest comfort (72 of 100) and the knife edge design produced the highest (87 out of 100). Soft contact lens wear induces circumlimbal staining, the level of staining being influenced by the contact lens edge design. However, high level of circumlimbal staining is not associated with decreased comfort.
McNabb, Ryan P.; Challa, Pratap; Kuo, Anthony N.; Izatt, Joseph A.
2015-01-01
Clinically, gonioscopy is used to provide en face views of the ocular angle. The angle has been imaged with optical coherence tomography (OCT) through the corneoscleral limbus but is currently unable to image the angle from within the ocular anterior chamber. We developed a novel gonioscopic OCT system that images the angle circumferentially from inside the eye through a custom, radially symmetric, gonioscopic contact lens. We present, to our knowledge, the first 360° circumferential volumes (two normal subjects, two subjects with pathology) of peripheral iris and iridocorneal angle structures obtained via an internal approach not typically available in the clinic. PMID:25909021
Edlich, Richard F; Greene, Jill A; Long, William B
2006-01-01
Dr. Robert C. Allen was a gifted educator, as well as experienced ophthalmologist, who was a close personal friend of Dr. Edlich at the University of Virginia Health System. While serving on the faculty at the University of Virginia Health System, Dr. Allen proved to be a compassionate physician, who developed close personal relationships with the residents, faculty, and his patients. Dr. Allen was invited by Dr Edlich to be a member of the Editorial Board of the Journal of Long-Term Effects of Medical Implants. When Dr. Allen told Dr. Edlich that he had ocular melanoma in 2000, this news was a wake-up call to Dr. Edlich on the need to prevent skin cancer, as well as ocular melanoma. Empowered by this news, Dr. Edlich was honored to co-author four articles on skin cancer prevention, as well as the latest article focusing on prevention of ocular melanoma. The Ocular Melanoma Foundation (Richmond, VA (USA)) was founded in 2003 by Dr. Robert C. Allen to increase awareness, enhance education, and provide advocacy among both patients and health care professionals regarding this rare, but potentially lethal cancer. It has a website that provides patient information, up-to-date information and enables communication/ discourse between and among patients and practitioners (admin@ocularmelanoma.org). Dr. Allen died on March 24, 2005, at his home surrounded by family and loved ones. When surgeons are faced with challenging healthcare diseases, Dr. Edlich's mentor, Dr. Owen Wangensteen, advised Dr. Edlich that he should seek the advice and guidance of skilled basic scientists, who are familiar with the problem. Dr. Wangensteen is recognized as the greatest surgical teacher during the 20th century. Consequently, Dr. Edlich enlisted the advice and guidance from the two co-authors of the next article regarding the scientific basis for the selection of sunglasses to prevent the development of cataracts, pterygia, skin cancer, as well as ocular melanoma. Dr. Reichow is a Professor of Optometry at Pacific University College of Optometry (Forest Grove, OR (USA)). Dr. Citek is Associate Professor of Optometry at Pacific University College of Optometry (Forest Grove (USA)). In their comprehensive evaluation of sunglasses, they found some disturbing results. Despite being endorsed by The Skin Cancer Foundation, the Walgreens eyewear samples offer only partial protection to the potential hazards of sunlight exposure. Those individuals who spend considerable time outdoors should seek sun filter eyewear with impact resistant polycarbonate lenses that provide 100% ultraviolet filtration, high levels of blue light filtration, and full visual field lens/frame coverage as provided by high wrap eyewear. There are several brands that offer products with such protective characteristics. Performance sun eyewear by Nike Vision (Nike Inc., Portland OR [USA]), available in both corrective and plano (nonprescription) forms, is one such brand incorporating these protective features, as well as patented optical and tint designs. Numerous Nike styles offer interchangeable lens options to meet the changing environmental conditions encountered outdoors. These technologies are incorporated into performance-driven frame designs inspired by feedback from some of the world's best athletes. Nonprescription Nike eyewear are available on-line at http://www.nike.com/nikevision, as well as at various well-known retail outlets. Nonprescription and prescription Nike eyewear are also available at the offices of many eye care professionals. Even though our latest report did not include soft contact lens, it is important to emphasize that Dr. Reichow and Dr. Citek have played a leadership role in coordinating the development of the Nike MAXSIGHT, an innovative fully tinted soft contact lens. This contact lens provides distortion-free optics, whether or not you wear prescription contacts. They filter out more than 90% of harmful blue light and 95% of UVA and UVB. For the contact lens, you should go to the website for more information http://www.nike.com/nikevision/content.html. The website has a list of practitioners who can service the patients with the respective sunglasses. With their exciting technologic advances in sunglass products, as well as tinted soft contact lens, the authors would encourage Nike Vision to develop an expanded international marketing program that allows all individuals in the world to easily purchase its products.
Ocular injuries due to projectile impacts.
Scott, W R; Lloyd, W C; Benedict, J V; Meredith, R
2000-01-01
An animal model has been developed using enucleated porcine eyes to evaluate ocular trauma. The eyes were pressurized to approximately 18 mmHg and mounted in a container with a 10% gelatin mixture. The corneas of sixteen pressurized eyes were impacted by a blunt metal projectile (mass of 2.6 gm, 3.5 gm or 45.5 gm) at velocities of 4.0 to 38.1 m/s. The impacted eyes were evaluated by an ophthalmologist. A numerical classification scheme was used to categorize the severity of the ocular injury. A chi-squared test indicates that the injury level is associated with the kinetic energy (KE) and not the momentum of the projectile. The enucleated eyes began to experience lens dislocations when the KE of the projectile was approximately 0.75 Nm, and retinal injuries when the KE was approximately 1.20 Nm.
Ocular Injuries Due to Projectile Impacts
(Michael) Scott, William R.; Lloyd, William C.; Benedict, James V.; Meredith, Roy
2000-01-01
An animal model has been developed using enucleated porcine eyes to evaluate ocular trauma. The eyes were pressurized to approximately 18mmHg and mounted in a container with a 10% gelatin mixture. The corneas of sixteen pressurized eyes were impacted by a blunt metal projectile (mass of 2.6gm, 3.5gm or 45.5gm) at velocities of 4.0 to 38.1 m/s. The impacted eyes were evaluated by an ophthalmologist. A numerical classification scheme was used to categorize the severity of the ocular injury. A chi-squared test indicates that the injury level is associated with the kinetic energy (KE) and not the momentum of the projectile. The enucleated eyes began to experience lens dislocations when the KE of the projectile was approximately 0.75Nm, and retinal injuries when the KE was approximately 1.20Nm. PMID:11558084
The mechanism of transient myopia induced by sulfonamide therapy.
Bovino, J A; Marcus, D F
1982-07-01
We performed acute and convalescent A-scan echographic ocular measurements documenting the anterior chamber depth, lens thickness, and axial length of a patient with acute transient sulfamethoxazole-induced myopia. Shallowing of the anterior chamber, independent of changes in the thickness of the lens, was the only anatomic variation found that could explain the myopia. Swelling of the ciliary body, with forward movement of the lens-iris diaphragm, could produce this transient anatomic change.
The Effect of Age, Accommodation and Refractive Error on the Adult Human Eye
Richdale, Kathryn; Bullimore, Mark A.; Sinnott, Loraine T.; Zadnik, Karla
2015-01-01
Purpose To quantify changes in ocular dimensions associated with age, refractive error, and accommodative response, in vivo, in 30- to 50-year-old human subjects. Methods The right eyes of 91 adults were examined using ultrasonography, phakometry, keratometry, pachymetry, interferometry, anterior segment optical coherence tomography, and high resolution magnetic resonance imaging. Accommodation was measured subjectively with a push-up test and objectively using open-field autorefraction. Regression analyses were used to assess differences in ocular parameters with age, refractive error and accommodation. Results With age, crystalline lens thickness increased (0.03 mm/yr), anterior lens curvature steepened (0.11 mm/yr), anterior chamber depth decreased (0.02 mm/y) and lens equivalent refractive index decreased (0.001 /y) (all p < 0.01). With increasing myopia, there were significant increases in axial length (0.37 mm/D), vitreous chamber depth (0.34 mm/D), vitreous chamber height (0.09 mm/D) and ciliary muscle ring diameter (0.10 mm/D) (all p < 0.05). Increasing myopia was also associated with steepening of both the cornea (0.16 mm/D) and anterior lens surface (0.011 mm/D) (both p < 0.04). With accommodation, the ciliary muscle ring diameter decreased (0.08 mm/D), and the muscle thinned posteriorly (0.008 mm/D), allowing the lens to shorten equatorially (0.07 mm/D) and thicken axially (0.06 mm/D) (all p < 0.03). Conclusions Refractive error is significantly correlated with not only the axial dimensions, but the anterior equatorial dimension of the adult eye. Further testing and development of accommodating intraocular lenses should account for differences in patients’ preoperative refractive error. PMID:26703933
Ocular refractive and biometric characteristics in patients with tilted disc syndrome.
Dehghani, Cirous; Nowroozzadeh, Mohammad Hosein; Shankar, Sunita; Razeghinejad, Mohammad Reza
2010-12-01
Tilted disc syndrome (TDS) is associated with characteristic ocular findings. The purpose of this study was to evaluate the ocular, refractive, and biometric characteristics in patients with TDS. This case-control study included 41 eyes of 25 patients who had established TDS and 40 eyes of 20 healthy control subjects. All participants underwent a complete ocular examination, including refraction and analysis using Fourier transformation, slit lamp biomicroscopy, pachymetry, keratometry, and ocular biometry. Corneal topography examinations were performed in the syndrome group only. There were no significant differences in spherical equivalent (P = 0.13) and total astigmatism (P = 0.37) between groups. However, mean best spectacle-corrected visual acuity (Log Mar) was significantly worse in TDS patients (P = 0.003). The lenticular astigmatism was greater in the syndrome group, whereas the corneal component was greater in controls (P = 0.059 and P = 0.028, respectively). The measured biometric features were the same in both groups, except for the lens thickness and lens-axial length factor, which were greater in the TDS group (P = 0.007 and P = 0.055, respectively). Clinically significant lenticular astigmatism, more oblique corneal astigmatism, and thicker lenses were characteristic findings in patients with TDS. Copyright © 2010 American Optometric Association. Published by Elsevier Inc. All rights reserved.
Myopic refractive shift represents dense nuclear sclerosis and thin lens in lenticular myopia.
Cho, Yang Kyung; Huang, Wei; Nishimura, Eiichi
2013-09-01
It is not rare to meet unilateral nuclear sclerotic cataracts with myopic refractive changes (lenticular myopia) compared with the fellow eye in the ophthalmic examination of patients with decreased visual acuity. To determine the relationship between the myopic refractive changes and interocular differences of parameters, we investigated the interocular differences of ocular parameters between a lenticular myopic eye and the fellow eye. This retrospective study included 68 eyes of 34 patients, who showed unilateral lenticular myopia. We compared the dimensions of ocular component, such as anterior chamber depth, anterior chamber volume, lens thickness, vitreous chamber depth, lens position, lens density of nuclear sclerosis, anterior lens curvature and myopic refractive changes (spherical equivalent refraction) between the lenticular myopic eye and the myopic refractive change were examined. Statistically significant differences were found between the lenticular myopic eye and the fellow eye for anterior chamber depth (p = 0.015) anterior chamber volume (p = 0.031), lens thickness (p < 0.001), lens density of the nuclear sclerosis (p < 0.001) and the spherical equivalent myopic refractive changes (p < 0.001). Based on univariate analysis, the interocular difference in spherical equivalent refraction was significantly correlated with interocular differences of the density of the nuclear sclerosis (r = 0.79, p < 0.001), lens thickness (r = -0.70, p < 0.001) and vitreous chamber depth (r = 0.43, p = 0.012). Based on multiple regression analysis, the interocular difference in spherical equivalent refraction was significantly correlated with interocular differences of density of nuclear sclerosis (p < 0.001) and lens thickness (p = 0.007). The difference in myopic spherical change reflects the differences in the severity of nuclear sclerosis and lens thickness between the lenticular myopic eye and the fellow eye. © 2013 The Authors. Clinical and Experimental Optometry © 2013 Optometrists Association Australia.
Contact lens wear is intrinsically inflammatory.
Efron, Nathan
2017-01-01
Eye-care practitioners typically associate ocular inflammation during contact lens wear with serious complications such as microbial keratitis; however, more subtle mechanisms may be at play. This paper tests the notion that contact lens wear is intrinsically inflammatory by exploring whether uncomplicated contact lens wear meets the classical, clinical definition of inflammation - rubor (redness), calor (heat), tumor (swelling), dolor (pain) and functio laesa (loss of function) - as well as the contemporary, sub-clinical definition of inflammation (cellular and biochemical reactions). It is demonstrated that all of these clinical and sub-clinical criteria are met with hydrogel lens wear and most are met with silicone hydrogel lens wear, indicating that uncomplicated contact lens wear is intrinsically inflammatory. Consideration of both traditional and contemporary thinking about the role of inflammation in the human body leads to the perhaps surprising conclusion that the chronic, low grade, sub-clinical inflammatory status of the anterior eye during contact lens wear, which may be termed 'para-inflammation', is a positive, protective phenomenon, whereby up-regulation of the immune system, in a non-damaging way, maintains the eye in a state of 'heightened alert', ready to ward off any extrinsic noxious challenge. Characterisation of this inflammatory status may lead to the development of lens engineering or pharmacological strategies to modulate contact lens-induced inflammation, so as to render lens wear more safe and comfortable. © 2016 Optometry Australia.
Koyama, Shinzo; Onozawa, Kazutoshi; Tanaka, Keisuke; Saito, Shigeru; Kourkouss, Sahim Mohamed; Kato, Yoshihisa
2016-08-08
We developed multiocular 1/3-inch 2.75-μm-pixel-size 2.1M- pixel image sensors by co-design of both on-chip beam-splitter and 100-nm-width 800-nm-depth patterned inner meta-micro-lens for single-main-lens stereo camera systems. A camera with the multiocular image sensor can capture horizontally one-dimensional light filed by both the on-chip beam-splitter horizontally dividing ray according to incident angle, and the inner meta-micro-lens collecting the divided ray into pixel with small optical loss. Cross-talks between adjacent light field images of a fabricated binocular image sensor and of a quad-ocular image sensor are as low as 6% and 7% respectively. With the selection of two images from one-dimensional light filed images, a selective baseline for stereo vision is realized to view close objects with single-main-lens. In addition, by adding multiple light field images with different ratios, baseline distance can be tuned within an aperture of a main lens. We suggest the electrically selective or tunable baseline stereo vision to reduce 3D fatigue of viewers.
Noninvasive diagnostic devices for diabetes through measuring tear glucose.
Zhang, Jin; Hodge, William; Hutnick, Cindy; Wang, Xianbin
2011-01-01
This article reviews the development of a noninvasive diagnostic for diabetes by detecting ocular glucose. Early diagnosis and daily management are very important to diabetes patients to ensure a healthy life. Commercial blood glucose sensors have been used since the 1970s. Millions of diabetes patients have to prick their finger for a drop of blood 4-5 times a day to check blood glucose levels--almost 1800 times annually. There is a strong need to have a noninvasive device to help patients to manage the disease easily and painlessly. Instead of detecting the glucose in blood, monitoring the glucose level in other body fluids may provide a feasible approach for noninvasive diagnosis and diabetes control. Tear glucose has been studied for several decades. This article reviews studies on ocular glucose and its monitoring methods. Attempts to continuously monitor the concentration of tear glucose by using contact lens-based sensors are discussed as well as our current development of a nanostructured lens-based sensor for diabetes. This disposable biosensor for the detection of tear glucose may provide an alternative method to help patients manage the disease conveniently. © 2010 Diabetes Technology Society.
Sychev, Yevgeniy V; Zepeda, Emily M; Lam, Deborah L
2017-09-01
Acute development of cataracts that may be transient is known to occur during correction of diabetic ketoacidosis and hyperglycemic hyperosmolar syndrome. Nettleship in 1885 was the first to describe the presence of a transient cataract in three diabetic patients that grew worse and eventually cleared with treatment. 1 We present a case of irreversible cataracts formed by nuclear fracture of the crystalline lens after hyperglycemia correction, an entity that has not yet been described. A 67 year-old Caucasian man presented with sudden bilateral vision loss one week after a week-long hospitalization in the intensive care unit for correction of hyperglycemia in the setting of hyperglycemic hyperosmolar syndrome requiring an insulin drip. This was caused by spontaneous fractures of the lens nuclei causing bilateral irreversible cataracts. The patient underwent uncomplicated bilateral cataract extraction resulting in restoration of normal vision. Acute transient cataracts that develop during correction of hyperglycemic hyperosmolar syndrome are thought to result from osmotic lens swelling. In this case report, internal fracture of the lens was produced by mechanical forces generated in the process of lens swelling occurring as a consequence of initial hyperglycemia and its subsequent correction. This case represents a rare ocular complication of hyperglycemia correction, and provides new evidence that mechanical forces can be part of diabetic cataractogenesis.
[Preservatives in ophthalmology].
Messmer, E M
2012-11-01
Preservatives are a legal requirement for eye drops in multidose containers. Moreover, they are necessary for stabilization and intraocular penetration for a number of ophthalmic preparations. Most preservatives act in a relatively unspecific manner as detergents or by oxidative mechanisms and thereby cause side effects at the ocular surface. They may also affect the lens, trabecular meshwork and the retina. Benzalkonium chloride is the most commonly used preservative in ophthalmology and is more toxic than other or newer preservatives, such as polyquaternium-1 (Polyquad), sodium perborate, oxychloro-complex (Purite®) and SofZia. Preservative-free topical medication is highly recommended for patients with ocular surface disease, frequent eye drop administration, proven allergy to preservatives and contact lens wear.
Rosa, Juliana Maria da Silva; Andrade Sobrinho, Marcelo Vicente de; Lipener, César
2016-02-01
Alport Syndrome is a hereditary disease that is caused by a gene mutation and affects the production of collagen in basement membranes; this condition causes hemorrhagic nephritis associated with deafness and ocular changes. The X-linked form of this disease is the most common and mainly affects males. Typical ocular findings are dot-and-fleck retinopathy, anterior lenticonus, and posterior polymorphous corneal dystrophy. Some cases involving polymorphous corneal dystrophy and corneal ectasia have been previously described. Here we present a case report of a 33-year-old female with Alport syndrome, posterior polymorphous corneal dystrophy, and irregular astigmatism, whose visual acuity improved with a rigid gas permeable contact lens.
Cited2 is required for the proper formation of the hyaloid vasculature and for lens morphogenesis
Chen, Yu; Doughman, Yong-qiu; Gu, Shi; Jarrell, Andrew; Aota, Shin-ichi; Cvekl, Ales; Watanabe, Michiko; Dunwoodie, Sally L.; Johnson, Randall S.; van Heyningen, Veronica; Kleinjan, Dirk A.; Beebe, David C.; Yang, Yu-Chung
2009-01-01
Cited2 is a transcriptional modulator with pivotal roles in different biological processes. Cited2-deficient mouse embryos manifested two major defects in the developing eye. An abnormal corneal-lenticular stalk was characteristic of Cited2−/− developing eyes, a feature reminiscent of Peters’ anomaly, which can be rescued by increased Pax6 gene dosage in Cited2−/− embryonic eyes. In addition, the hyaloid vascular system showed hyaloid hypercellularity consisting of aberrant vasculature, which might be correlated with increased VEGF expression in the lens. Deletion of Hif1a (which encodes HIF-1α) in Cited2−/− lens specifically eliminated the excessive accumulation of cellular mass and aberrant vasculature in the developing vitreous without affecting the corneal-lenticular stalk phenotype. These in vivo data demonstrate for the first time dual functions for Cited2: one upstream of, or together with, Pax6 in lens morphogenesis; and another in the normal formation of the hyaloid vasculature through its negative modulation of HIF-1 signaling. Taken together, our study provides novel mechanistic revelation for lens morphogenesis and hyaloid vasculature formation and hence might offer new insights into the etiology of Peters’ anomaly and ocular hypervascularity. PMID:18653562
Form deprivation and lens-induced myopia: are they different?
Morgan, Ian G.; Ashby, Regan S.; Nickla, Debora L.; Guggenheim, Jeremy A.
2013-01-01
Animal models have been crucial in shaping our understanding of emmetropisation as an active, visually-guided mechanism for overcoming innate refractive errors. For instance, when a ‘minus’ power spectacle lens is mounted in front of the eye of a juvenile animal, the eye is cued to thin its choroid and accelerate its rate of axial elongation. Such altered ocular growth responses serve to attenuate the imposed defocus and so continue over a period of days, weeks or months (depending on the rate of emmetropisation of the species concerned) until the eye attains its optimal refraction. Notably, refracted without the minus lens in place, the eye of an animal emmetropising to a minus lens is myopic (its axial length now being excessive for its anterior segment optics). Similar ocular growth changes are seen with form deprivation, typically achieved by covering the eye with a frosted diffuser, and preventing the eye from receiving clear vision. However while both minus lens wear and form deprivation induce axial myopia, the absence of meaningful visual feedback allows growth to continue in an ‘open-loop’ manner in the latter case, limited mostly by the duration of treatment. Here, Ian Morgan and Regan Ashby present the evidence that form deprivation and lens-induced myopia share the same physiological mechanisms, while Debora Nickla presents the opposing evidence that the underlying mechanisms are different. PMID:23662966
Randomized Crossover Trial of Silicone Hydrogel Presbyopic Contact Lenses.
Sivardeen, Ahmed; Laughton, Deborah; Wolffsohn, James S
2016-02-01
To assess the performance of four commercially available silicone hydrogel multifocal monthly contact lens designs against monovision. A double-masked randomized crossover trial of Air Optix Aqua multifocal, PureVision 2 for Presbyopia, Acuvue OASYS for Presbyopia, Biofinity multifocal, and monovision with Biofinity contact lenses was conducted on 35 presbyopes (54.3 ± 6.2 years). After 4 weeks of wear, visual performance was quantified by high- and low-contrast visual acuity under photopic and mesopic conditions, reading speed, defocus curves, stereopsis, halometry, aberrometry, Near Activity Visual Questionnaire rating, and subjective quality of vision scoring. Bulbar, limbal, and palpebral hyperemia and corneal staining were graded to monitor the impact of each contact lens on ocular physiology. High-contrast photopic visual acuity (p = 0.102), reading speed (F = 1.082, p = 0.368), and aberrometry (F = 0.855, p = 0.493) were not significantly different between presbyopic lens options. Defocus curve profiles (p < 0.001), stereopsis (p < 0.001), halometry (F = 4.101, p = 0.004), Near Activity Visual Questionnaire (F = 3.730, p = 0.007), quality of vision (p = 0.002), bulbar hyperemia (p = 0.020), and palpebral hyperemia (p = 0.012) differed significantly between lens types, with the Biofinity multifocal lens design principal (center-distance lens was fitted to the dominant eye and a center-near lens to the nondominant eye) typically outperforming the other lenses. Although ocular aberration variation between individuals largely masks the differences in optics between current multifocal contact lens designs, certain design strategies can outperform monovision, even in early presbyopes.
Predicting crystalline lens fall caused by accommodation from changes in wavefront error
He, Lin; Applegate, Raymond A.
2011-01-01
PURPOSE To illustrate and develop a method for estimating crystalline lens decentration as a function of accommodative response using changes in wavefront error and show the method and limitations using previously published data (2004) from 2 iridectomized monkey eyes so that clinicians understand how spherical aberration can induce coma, in particular in intraocular lens surgery. SETTINGS College of Optometry, University of Houston, Houston, USA. DESIGN Evaluation of diagnostic test or technology. METHODS Lens decentration was estimated by displacing downward the wavefront error of the lens with respect to the limiting aperture (7.0 mm) and ocular first surface wavefront error for each accommodative response (0.00 to 11.00 diopters) until measured values of vertical coma matched previously published experimental data (2007). Lens decentration was also calculated using an approximation formula that only included spherical aberration and vertical coma. RESULTS The change in calculated vertical coma was consistent with downward lens decentration. Calculated downward lens decentration peaked at approximately 0.48 mm of vertical decentration in the right eye and approximately 0.31 mm of decentration in the left eye using all Zernike modes through the 7th radial order. Calculated lens decentration using only coma and spherical aberration formulas was peaked at approximately 0.45 mm in the right eye and approximately 0.23 mm in the left eye. CONCLUSIONS Lens fall as a function of accommodation was quantified noninvasively using changes in vertical coma driven principally by the accommodation-induced changes in spherical aberration. The newly developed method was valid for a large pupil only. PMID:21700108
Raman Spectroscopy of Ocular Tissue
NASA Astrophysics Data System (ADS)
Ermakov, Igor V.; Sharifzadeh, Mohsen; Gellermann, Warner
The optically transparent nature of the human eye has motivated numerous Raman studies aimed at the non-invasive optical probing of ocular tissue components critical to healthy vision. Investigations include the qualitative and quantitative detection of tissue-specific molecular constituents, compositional changes occurring with development of ocular pathology, and the detection and tracking of ocular drugs and nutritional supplements. Motivated by a better understanding of the molecular mechanisms leading to cataract formation in the aging human lens, a great deal of work has centered on the Raman detection of proteins and water content in the lens. Several protein groups and the hydroxyl response are readily detectable. Changes of protein compositions can be studied in excised noncataractous tissue versus aged tissue preparations as well as in tissue samples with artificially induced cataracts. Most of these studies are carried out in vitro using suitable animal models and conventional Raman techniques. Tissue water content plays an important role in optimum light transmission of the outermost transparent ocular structure, the cornea. Using confocal Raman spectroscopy techniques, it has been possible to non-invasively measure the water to protein ratio as a measure of hydration status and to track drug-induced changes of the hydration levels in the rabbit cornea at various depths. The aqueous humor, normally supplying nutrients to cornea and lens, has an advantageous anterior location for Raman studies. Increasing efforts are pursued to non-invasively detect the presence of glucose and therapeutic concentrations of antibiotic drugs in this medium. In retinal tissue, Raman spectroscopy proves to be an important tool for research into the causes of macular degeneration, the leading cause of irreversible vision disorders and blindness in the elderly. It has been possible to detect the spectral features of advanced glycation and advanced lipooxydation end products in excised tissue samples and synthetic preparations and thus to identify potential biomarkers for the onset of this disease. Using resonance Raman detection techniques, the concentration and spatial distribution of macular pigment, a protective compound, can be detected in the living human retina Useable in clinical settings for patient screening, the technology is suitable to investigate correlations between pigment concentration levels and risk for macular degeneration and to monitor increases in pigment levels occurring as a result of dietary intervention strategies.
Spontaneous Blinking from a Tribological Viewpoint.
Pult, Heiko; Tosatti, Samuele G P; Spencer, Nicholas D; Asfour, Jean-Michel; Ebenhoch, Michael; Murphy, Paul J
2015-07-01
The mechanical forces between the lid wiper and the ocular surface, and between a contact lens and the lid wiper, are reported to be related to dry eye symptoms. Furthermore, the mechanical forces between these sliding partners are assumed to be related to the ocular signs of lid-wiper epitheliopathy (LWE) and lid-parallel conjunctival folds (LIPCOF). Recent literature provides some evidence that a contact lens with a low coefficient of friction (CoF) improves wearing comfort by reducing the mechanical forces between the contact lens surface and the lid wiper. This review discusses the mechanical forces during spontaneous blinks from a tribological perspective, at both low and high sliding velocities, in a healthy subject. It concludes that the coefficient of friction of the ocular surfaces appears to be strongly comparable to that of hydrophilic polymer brushes at low sliding velocity, and that, with increased sliding velocity, there is no wear at the sliding partners' surfaces thanks to the presence of a fluid film between the two sliding partners. In contrast, in the case of dry eye, the failure to maintain a full fluid film lubrication regime at high blinking speeds may lead to increased shear rates, resulting in deformation and wear of the sliding pairs. These shear rates are most likely related to tear film viscosity. Copyright © 2015 Elsevier Inc. All rights reserved.
Simulation of Blast Loading on an Ultrastructurally-based Computational Model of the Ocular Lens
2012-10-01
mechanisms of traumatic cataract forma - tion that may require cataract surgery (implantation of an intraocular lens (IOL)) are not well understood in...cornea and cutting through the iris and zonules. This was done by making a small incision with a diamond-head blade at the edge of the cornea and using
Anterior capsular rupture following blunt ocular injury
Gremida, Anas; Kassem, Iris; Traish, Aisha
2011-01-01
Summary A 10-year-old boy suffered a large, oblique anterior capsular tear following blunt injury to his right eye. The boy was followed daily for hyphema resolution and progressive traumatic cataract formation. After the hyphema had resolved, the lens was removed using an anterior approach and an intraocular lens was placed with excellent visual outcome. PMID:23362402
Co-ordinated ocular development from human iPS cells and recovery of corneal function.
Hayashi, Ryuhei; Ishikawa, Yuki; Sasamoto, Yuzuru; Katori, Ryosuke; Nomura, Naoki; Ichikawa, Tatsuya; Araki, Saori; Soma, Takeshi; Kawasaki, Satoshi; Sekiguchi, Kiyotoshi; Quantock, Andrew J; Tsujikawa, Motokazu; Nishida, Kohji
2016-03-17
The eye is a complex organ with highly specialized constituent tissues derived from different primordial cell lineages. The retina, for example, develops from neuroectoderm via the optic vesicle, the corneal epithelium is descended from surface ectoderm, while the iris and collagen-rich stroma of the cornea have a neural crest origin. Recent work with pluripotent stem cells in culture has revealed a previously under-appreciated level of intrinsic cellular self-organization, with a focus on the retina and retinal cells. Moreover, we and others have demonstrated the in vitro induction of a corneal epithelial cell phenotype from pluripotent stem cells. These studies, however, have a single, tissue-specific focus and fail to reflect the complexity of whole eye development. Here we demonstrate the generation from human induced pluripotent stem cells of a self-formed ectodermal autonomous multi-zone (SEAM) of ocular cells. In some respects the concentric SEAM mimics whole-eye development because cell location within different zones is indicative of lineage, spanning the ocular surface ectoderm, lens, neuro-retina, and retinal pigment epithelium. It thus represents a promising resource for new and ongoing studies of ocular morphogenesis. The approach also has translational potential and to illustrate this we show that cells isolated from the ocular surface ectodermal zone of the SEAM can be sorted and expanded ex vivo to form a corneal epithelium that recovers function in an experimentally induced animal model of corneal blindness.
[Internal astigmatism with other ocular lesions].
Limaiem, R; Baba, A; Bouraoui, R; Mghaieth, F; El Matri, L
2012-04-01
Astigmatism is a refractive defect whose origin is not always purely corneal, and is sometimes the result of corneal, crystalline lens or mixte contributions. The aim of our study is to report, through two cases, ocular lesions associated with a lenticular astigmatism and their evolution after treatment. In the first observation, it is a 25-year-old patient with a unilateral extra corneal astigmatism within the framework of the "tilted disc syndrome" associated with bilateral myopia. This patient has received treatment by Lasik. The postoperative course was good with a decline of 5 ans. The second observation is that of a patient aged 35 years without having a general history with a posterior lenticonus associated with keratoconus responsible for a major mixed astigmatism. She received combined surgery: penetrating keratoplasty with lens extraction and implantation of an artificial lens. The evolution was good with good visual recovery. The balance of internal astigmatism must include the systematic achievement of a subjective and objective refraction under cycloplegia and corneal topography. The search for etiology is critical to screen for eye or general disease and guide the therapeutic strategy. Knowledge of the refractive power of the cornea and crystalline lens of astigmatism separately would be important for surgery refractive and crystalline lens surgery. Copyright © 2011 Elsevier Masson SAS. All rights reserved.
Chromium-picolinate induced ocular changes: Protective role of ascorbic acid.
Mahmoud, Amany A; Karam, Sawsan H; Abdel-Wahhab, Mosaad A
2006-09-21
Chromium-picolinate (Cr-picolinate) is a popular nutritional supplement; however its safety has been questioned with regard to its ability to act as a clastogen. The aim of the present work was to evaluate the biochemical, histological and morphological changes in the cornea and lens following oral administration of Cr-picolinate and the possible protective effect of Vitamin C. Ninety male Sprague-Dawley rats were divided into five groups included the control group, the groups treated with Cr-picolinate (0.8 and 1.5 mg/100 g b.w.) alone or in combination with Vitamin C (0.5 mg/100 g b.w.) for 8 weeks. The results indicated that the high dose of Cr-picolinate induced a significant decrease in SOD, GSH, Na(+)-, K(+)-ATPase levels, and a significant increase in MDA level. Severe morphological and histological changes in the cornea and lens accompanied with a decrease in the total soluble protein of the lens homogenate and changes in the crystalline fractions in lens. Vitamin C supplementation succeeded to restore these changes to great extent. It could be concluded that consumption of Cr-picolinate for a long time induced several hazards to cornea and lens. Supplementation with extra amounts of Vitamin C may be useful to restrain the Cr-picolinate induced ocular changes.
Mester, Ulrich; Lohmann, Chris; Pleyer, U; Steinkamp, G; Völcker, E; Kruger, H; Raj, Palaniswamy Sunder
2002-01-01
To compare the efficacy, tolerability and local tolerance of diclofenac sodium 0.1% containing hydroxypropylgamma cyclodextrin preserved with benzalkonium chloride 0.005% (Voltaren Ophtha CD), with that of diclofenac sodium 0.1% preserved with thiomersal 0.004% (Voltaren Ophtha) in the treatment of inflammation after cataract-intraocular lens surgery. Randomised 2:1, double-masked, parallel-group study in six centres in Germany. 299 patients scheduled to undergo phacoemulsification with posterior chamber intraocular lens implantation. Study medications were instilled four times in the 30 minutes before surgery and four times daily from the first postoperative day. The key efficacy variable was the reduction in anterior chamber flare (photons/millisecond) from day 1 to day 6 to 8. Patients underwent comprehensive ocular examinations, including laser flaremetry (KOWA), preoperatively and postoperatively at days 1, 6 to 8 and 24 to 32. 268 patients (Voltaren Ophtha CD 177, Voltaren Ophtha 91) completed the day 6 to 8 visit without any protocol violations. Reduction in the degree of intraocular inflammation with Voltaren Ophtha CD was equivalent to that achieved with Voltaren Ophtha at the day 6 to 8 [95% confidence interval (CI) -3.07 to +0.54] and day 24 to 32 (95% CI -1.44 to +1.40) visits. Although there was no significant (p = 0.464) difference between the two study groups in patients' global assessment of local tolerance at day 24 to 32, ocular discomfort was significantly (p = 0.023) less with Voltaren Ophtha CD compared with Voltaren Ophtha. Voltaren Ophtha CD was as effective and well tolerated but had less ocular discomfort compared with Voltaren Ophtha in the treatment of ocular inflammation after phacoemulsification with intraocular lens implantation. This new formulation of diclofenac sodium 0.1% may be used as an alternative to the existing formulations of ophthalmic diclofenac sodium 0.1%.
Conjunctival epithelial flap in continuous contact lens wear.
Graham, Andrew D; Truong, Tan N; Lin, Meng C
2009-04-01
Composed of sheets of cells detached from the underlying conjunctiva, conjunctival epithelial flap (CEF) is a recently reported phenomenon associated with contact lens wear with potential consequences for ocular health. Although CEF is generally asymptomatic, it is not known to what extent it might increase the longer-term risk of discomfort, inflammatory response, or infection. In this study, we use survival analysis methods to obtain unbiased estimates of the probability of developing CEF, the mean survival time free of CEF, and the effects of age, gender, ethnicity, and contact lens type. Two hundred four subjects were recruited for a continuous wear (CW) study of silicone hydrogel (SiH) and gas permeable (GP) contact lenses. Subjects were examined by optometrists throughout contact lens adaptation and CW periods. Statistical methods included the Kaplan-Meier nonparametric estimator of the survival function and the Cox proportional hazards model for estimating the relative effects of covariates. Of the 204 subjects, 72 (35%) developed CEF. In 64% of cases, CEFs were observed bilaterally. The majority of cases (90.3%) presented with CEF in the superior conjunctiva. Mean survival time free of CEF was longer for GP lenses (94.3 days) than for SiH lenses (76.5 days), and the probability of developing CEF was significantly greater for SiH lenses (p = 0.002). Although there was some evidence that women and non-Asians remain free of CEF longer, the effects of age, gender, and ethnicity were not statistically significant. There was a significantly increased risk of CEF in subjects wearing SiH lenses, compared with GP lenses. Subjects wearing SiH lenses remained free of CEF for a shorter time on average. Further study is needed to determine whether the increased incidence of CEF in CW with SiH lenses poses an increased risk of adverse ocular response or infection.
Measurement of ocular aberrations in downward gaze using a modified clinical aberrometer
Ghosh, Atanu; Collins, Michael J; Read, Scott A; Davis, Brett A; Iskander, D. Robert
2011-01-01
Changes in corneal optics have been measured after downward gaze. However, ocular aberrations during downward gaze have not been previously measured. A commercial Shack-Hartmann aberrometer (COAS-HD) was modified by adding a relay lens system and a rotatable beam splitter to allow on-axis aberration measurements in primary gaze and downward gaze with binocular fixation. Measurements with the modified aberrometer (COAS-HD relay system) in primary and downward gaze were validated against a conventional aberrometer. In human eyes, there were significant changes (p<0.05) in defocus C(2,0), primary astigmatism C(2,2) and vertical coma C(3,−1) in downward gaze (25 degrees) compared to primary gaze, indicating the potential influence of biomechanical forces on the optics of the eye in downward gaze. To demonstrate a further clinical application of this modified aberrometer, we measured ocular aberrations when wearing a progressive addition lens (PAL) in primary gaze (0 degree), 15 degrees downward gaze and 25 degrees downward gaze. PMID:21412451
Gooi, Patrick; Ahmed, Yusuf; Ahmed, Iqbal Ike K
2014-07-01
We describe the use of a microscope-mounted wide-angle point-of-view camera to record optimal hand positions in ocular surgery. The camera is mounted close to the objective lens beneath the surgeon's oculars and faces the same direction as the surgeon, providing a surgeon's view. A wide-angle lens enables viewing of both hands simultaneously and does not require repositioning the camera during the case. Proper hand positioning and instrument placement through microincisions are critical for effective and atraumatic handling of tissue within the eye. Our technique has potential in the assessment and training of optimal hand position for surgeons performing intraocular surgery. It is an innovative way to routinely record instrument and operating hand positions in ophthalmic surgery and has minimal requirements in terms of cost, personnel, and operating-room space. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2014 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Impact of Eye Cosmetics on the Eye, Adnexa, and Ocular Surface.
Ng, Alison; Evans, Katharine; North, Rachel V; Jones, Lyndon; Purslow, Christine
2016-07-01
Despite the fact that cosmetic products undergo rigorous testing to ensure they are safe for human use, some users report mild discomfort following their application. The cutaneous changes, such as allergic dermatitis, are well reported, but the ocular changes associated with eye cosmetic use are less so. Some pigmented cosmetic products may accumulate within the lacrimal system and conjunctivae over many years of use, but immediate reports of eye discomfort after application are most common. Changes to the tear film and its stability may occur shortly after application, and contact lens wearers can also be affected by lens spoliation from cosmetic products. Additionally, creams used in the prevention of skin aging are often applied around the eyes, and retinoids present in these formulations can have negative effects on meibomian gland function and may be a contributing factor to dry eye disease. The aim of this review is to summarize current knowledge regarding the impact of cosmetic products on the eye, ocular surface, and tear film.
Relative axial myopia in Egr-1 (ZENK) knockout mice.
Schippert, Ruth; Burkhardt, Eva; Feldkaemper, Marita; Schaeffel, Frank
2007-01-01
Experiments in chickens have implicated the transcription factor ZENK (also known as Egr-1, NGFI-A, zif268, tis8, cef5, and Krox24) in the feedback mechanisms for visual control of axial eye growth and myopia development. ZENK is upregulated in retinal glucagon amacrine cells when axial eye growth is inhibited by positive spectacle lens wear and is downregulated when it is enhanced by negative spectacle lens wear, suggesting that ZENK may be linked to an inhibitory signal for axial eye growth. This study was undertaken to determine whether a Egr-1(-/-) knockout mouse mutant, lacking ZENK completely, has longer eyes and more myopic refraction, than do Egr-1(+/)(-) heterozygous and Egr-1(+/+) wild-type mice with near-identical genetic backgrounds. Eye growth and refractive development were tracked from day P28 to P98. Corneal radius of curvature was measured with infrared photokeratometry, refractive state with infrared photoretinoscopy, and ocular dimensions with low-coherence interferometry. As a functional vision test, grating acuity was determined in an automated optomotor task. The abundance of ZENK protein in the retina was quantified by immunohistochemistry. Egr-1 knockout mice had longer eyes and a relative myopic shift in refraction, with additional minor effects on anterior chamber depth and corneal radius of curvature. Paraxial schematic eye modeling suggested changes in the optics of the crystalline lens as well. With increasing age, the differences between mutant and wild-type mice declined, although the differences in refraction persisted over the observation period. Grating acuity was not affected by the lack of the Egr-1 protein during development. Although it has been shown that different mouse strains may have differently large eyes, the present study shows that a specific gene knockout can produce relative myopia, compared with the wild-type with near-identical genetic background. Further experiments are needed to determine whether the observed effects of Egr-1 deletion are due to changes in function within the retina or other ocular tissues or to changes of function in other systems that may affect ocular growth from outside the eye.
Potential sources of bacteria that are isolated from contact lenses during wear.
Willcox, M D; Power, K N; Stapleton, F; Leitch, C; Harmis, N; Sweeney, D F
1997-12-01
The aim of this paper was to determine the possible contamination sources of contact lenses during wear. Potential sources of the microbiota that colonized hydrogel contact lenses during wear were examined. The microorganisms that colonize contact lenses were grown, identified, and compared to those microorganisms that colonized the lower lid margins, upper bulbar conjunctiva, hands, and contact lens cases of contact lens wearers. In addition, the incidence of contamination of the domestic water supply in the Sydney area was obtained, and this was compared to the incidence of colonization of contact lenses by microorganisms in general and gram-negative bacteria in particular. There was a wide diversity of bacteria that were isolated from each site sampled. Coagulase-negative staphylococci and Propionibacterium spp. were the most common isolates from all ocular sites examined, and constituted the normal ocular microbiota. Other bacteria, including members of the families Enterobacteriaceae and Pseudomonadaceae, were isolated infrequently from all sites, but most frequently from contact lens cases. Statistical analysis revealed that there was a correlation between the isolation of bacteria from the contact lens and the lower lid margin (p < 0.001). Analysis of this correlation revealed that this was true for the normal microbiota. A correlation was also noted between the colonization of contact lenses by gram-negative bacteria and contamination of the domestic water supply. This study has demonstrated that the likely route for the normal ocular microbiota colonizing contact lenses is via the lid margins, whereas colonization by gram-negative bacteria, including potential agents of microbial keratitis, is likely to be from the domestic water supply.
NASA Astrophysics Data System (ADS)
Dubin, Stephen; Ansari, Rafat R.; Tulp, Orien; Steinberg, Sheldon; Koch, Seth; DellaVecchia, Michael A.; Cozmi, Mihaela; Victor, Mary
1999-06-01
The absence of verbal feedback, available from most human patients, is a major limitation in veterinary diagnosis in general and in the evaluation of ophthalmic lens opacity in particular. A novel compact dynamic light scattering (DLS) instrument, developed at NASA, offers significant mitigation to this limitation. It not only yields objective repeatable non-invasive estimation of lens opacity but also provides insight into the nature of chemical and physical alternations in the lens and other eye structures. For example, DLS measurements of the cataractous lens may be interpreted in terms of alpha crystalline protein size. In contrast to most conventional methods, the examination results are numerical and readily accommodate statistical analysis. We present results of DLS measurements in laboratory rabbits with naphthalene induced cataracts, rodents with genetically conditioned hypertension and/or diabetes mellitus; as well as applications of the DLS method in clinical veterinary patients. Use of DLS in examination of phacoemulsification fluid, urine and other biological materials, and potential applications in ocular toxically will also be discussed.
Emerging ocular biomarkers of Alzheimer disease.
van Wijngaarden, Peter; Hadoux, Xavier; Alwan, Mostafa; Keel, Stuart; Dirani, Mohamed
2017-01-01
Interest in reliable biomarkers of Alzheimer disease, the leading cause of dementia, has been fuelled by challenges in diagnosing the disease and monitoring disease progression as well as the response to therapy. A range of ocular manifestations of Alzheimer disease, including retinal and lens amyloid-beta accumulation, retinal nerve fiber layer loss, and retinal vascular changes, have been proposed as potential biomarkers of the disease. Herein, we examine the evidence regarding the potential value of these ocular biomarkers of Alzheimer disease. © 2016 Royal Australian and New Zealand College of Ophthalmologists.
Traumatic anterior dislocation of the crystalline lens and its surgical management.
Srećković, Sunčica; Janićijević Petrović, Mirjana; Jovanović, Svetlana; Paunović, Svetlana; Sarenac, Tatjana
2012-02-01
This paper reports a case of a 57-year old female who had sustained a blunt ocular trauma resulting in anterior dislocation of the crystalline lens and acute painful visual loss in the left eye. The patient was managed with anterior chamber intracapsular phacoemulsification through a small anterior capsulotomy, pars plana vitrectomy, and surgical iridotomy. Aphakia was corrected by a contact lens. Two months after the surgery, the best corrected visual acuity was 0.9 in the left eye. The vision and retina remained stable in her follow-up examination 1 year later. Anterior dislocation of the crystalline lens can cause severe complications so that dislocated lens should be removed immediately.
Integration of Defocus by Dual Power Fresnel Lenses Inhibits Myopia in the Mammalian Eye
McFadden, Sally A.; Tse, Dennis Y.; Bowrey, Hannah E.; Leotta, Amelia J.; Lam, Carly S.; Wildsoet, Christine F.; To, Chi-Ho
2014-01-01
Purpose. Eye growth compensates in opposite directions to single vision (SV) negative and positive lenses. We evaluated the response of the guinea pig eye to Fresnel-type lenses incorporating two different powers. Methods. A total of 114 guinea pigs (10 groups with 9–14 in each) wore a lens over one eye and interocular differences in refractive error and ocular dimensions were measured in each of three experiments. First, the effects of three Fresnel designs with various diopter (D) combinations (−5D/0D; +5D/0D or −5D/+5D dual power) were compared to three SV lenses (−5D, +5D, or 0D). Second, the ratio of −5D and +5D power in a Fresnel lens was varied (50:50 compared with 60:40). Third, myopia was induced by 4 days of exposure to a SV −5D lens, which was then exchanged for a Fresnel lens (−5D/+5D) or one of two SV lenses (+5D or −5D) and ocular parameters tracked for a further 3 weeks. Results. Dual power lenses induced an intermediate response between that to the two constituent powers (lenses +5D, +5D/0D, 0D, −5D/+5D, −5D/0D and −5D induced +2.1 D, +0.7 D, +0.1 D, −0.3 D, −1.6 D and −5.1 D in mean intraocular differences in refractive error, respectively), and changing the ratio of powers induced responses equal to their weighted average. In already myopic animals, continued treatment with SV negative lenses increased their myopia (from −3.3 D to −4.2 D), while switching to SV positive lenses or −5D/+5D Fresnel lenses reduced their myopia (by 2.9 D and 2.3 D, respectively). Conclusions. The mammalian eye integrates competing defocus to guide its refractive development and eye growth. Fresnel lenses, incorporating positive or plano power with negative power, can slow ocular growth, suggesting that such designs may control myopia progression in humans. PMID:24398103
Integration of defocus by dual power Fresnel lenses inhibits myopia in the mammalian eye.
McFadden, Sally A; Tse, Dennis Y; Bowrey, Hannah E; Leotta, Amelia J; Lam, Carly S; Wildsoet, Christine F; To, Chi-Ho
2014-02-14
Eye growth compensates in opposite directions to single vision (SV) negative and positive lenses. We evaluated the response of the guinea pig eye to Fresnel-type lenses incorporating two different powers. A total of 114 guinea pigs (10 groups with 9-14 in each) wore a lens over one eye and interocular differences in refractive error and ocular dimensions were measured in each of three experiments. First, the effects of three Fresnel designs with various diopter (D) combinations (-5D/0D; +5D/0D or -5D/+5D dual power) were compared to three SV lenses (-5D, +5D, or 0D). Second, the ratio of -5D and +5D power in a Fresnel lens was varied (50:50 compared with 60:40). Third, myopia was induced by 4 days of exposure to a SV -5D lens, which was then exchanged for a Fresnel lens (-5D/+5D) or one of two SV lenses (+5D or -5D) and ocular parameters tracked for a further 3 weeks. Dual power lenses induced an intermediate response between that to the two constituent powers (lenses +5D, +5D/0D, 0D, -5D/+5D, -5D/0D and -5D induced +2.1 D, +0.7 D, +0.1 D, -0.3 D, -1.6 D and -5.1 D in mean intraocular differences in refractive error, respectively), and changing the ratio of powers induced responses equal to their weighted average. In already myopic animals, continued treatment with SV negative lenses increased their myopia (from -3.3 D to -4.2 D), while switching to SV positive lenses or -5D/+5D Fresnel lenses reduced their myopia (by 2.9 D and 2.3 D, respectively). The mammalian eye integrates competing defocus to guide its refractive development and eye growth. Fresnel lenses, incorporating positive or plano power with negative power, can slow ocular growth, suggesting that such designs may control myopia progression in humans.
Zhang, Pengfei; Mocci, Jacopo; Wahl, Daniel J; Meleppat, Ratheesh Kumar; Manna, Suman K; Quintavalla, Martino; Muradore, Riccardo; Sarunic, Marinko V; Bonora, Stefano; Pugh, Edward N; Zawadzki, Robert J
2018-03-28
For in vivo mouse retinal imaging, especially with Adaptive Optics instruments, application of a contact lens is desirable, as it allows maintenance of cornea hydration and helps to prevent cataract formation during lengthy imaging sessions. However, since the refractive elements of the eye (cornea and lens) serve as the objective for most in vivo retinal imaging systems, the use of a contact lens, even with 0 Dpt. refractive power, can alter the system's optical properties. In this investigation we examined the effective focal length change and the aberrations that arise from use of a contact lens. First, focal length changes were simulated with a Zemax mouse eye model. Then ocular aberrations with and without a 0 Dpt. contact lens were measured with a Shack-Hartmann wavefront sensor (SHWS) in a customized AO-SLO system. Total RMS wavefront errors were measured for two groups of mice (14-month, and 2.5-month-old), decomposed into 66 Zernike aberration terms, and compared. These data revealed that vertical coma and spherical aberrations were increased with use of a contact lens in our system. Based on the ocular wavefront data we evaluated the effect of the contact lens on the imaging system performance as a function of the pupil size. Both RMS error and Strehl ratios were quantified for the two groups of mice, with and without contact lenses, and for different input beam sizes. These results provide information for determining optimum pupil size for retinal imaging without adaptive optics, and raise critical issues for design of mouse optical imaging systems that incorporate contact lenses. Copyright © 2018. Published by Elsevier Ltd.
Yeung, Ling; Wang, Nan-Kai; Wu, Wei-Chi; Chen, Kuan-Jen
2018-04-23
To evaluate the safety and efficacy of combined 23-gauge transconjunctival pars plana vitrectomy and scleral fixation of intraocular lens (IOL) without conjunctival dissection. A retrospective study in Chang Gung Memorial Hospital, Keelung and Taoyuan, Taiwan. Patients receiving combined 23-gauge transconjunctival pars plana vitrectomy and scleral fixation of IOL without conjunctival dissection were enrolled. The ocular findings, causes of lens complication, surgical procedures, type of IOL used, and complications were documented. We included 40 eyes from 39 patients (27 male, 12 female) with a mean age of 59.5 [standard deviation (±) 14.8] years old. The mean follow-up duration was 6.8 ± 5.4 months. The cause of lens complications was ocular trauma in 24 (60%) eyes, cataract surgery complications in 11 (28%) eyes, and spontaneous subluxation of crystalline lens in 5 (13%) eyes. The overall best corrected visual acuity (BCVA) (logMAR) improved from 1.359 ± 0.735 to 0.514 ± 0.582 (p < 0.001). The BCVA also improved significantly in each group with different causes of lens complications. Preoperative BCVA was the only factor associated with the postoperative visual outcome (p = 0.008). Most surgery-related complications were self-limited, including mild vitreous hemorrhage (5%), microhyphema (5%), transient elevated intraocular pressure (3%), and transient hypotony (3%). Cystoid macular edema and IOL decentration was found in 3 (8%) eyes and 1 (3%) eye respectively. Combined 23-gauge transconjunctival vitrectomy and scleral fixation of IOL without conjunctival dissection is effective and safe in managing a wide variety of lens complications, with good postoperative comfort and visual recovery. Retrospective study, not applicable.
Walsh, James E; Bergmanson, Jan P G; Saldana, Gerardo; Gaume, Amber
2003-01-01
Peak solar UV radiation (UVR) intensities are typically experienced in summer months. People living in the southern states of the United States, where the UVR frequently exceeds the recommended minimum erythema dose (MED), are at particular risk, especially outdoor workers. The present study analyzed summertime MED readings in Houston, TX, to assess the frequency of intensities regarded as unhealthy. The study also sought to assess whether UV-blocking hydrogel contact lenses provide ocular protection from these high doses. Readings, taken at midday using a UVR biometer, were analyzed to assess the potential UVR risk. The spectral response of the meter, modified by the spectral transmission curves of the contact lenses, allowed us to mathematically assess the ocular protection provided. In addition, ambient UVR measurements were taken at midday, using a portable UVR radiometer. The detector was adapted so that a standard diameter hydrogel contact lens could be placed over it to quantify the UV-blocking capabilities of the lens. The MED readings showed that the recommended safety standards were exceeded approximately at local midday 90% of the time. Model calculations and empirical data demonstrated that contact lenses attenuated the MED readings by up to 90%, bringing them well within the recommended Environmental Protection Agency safety standards. The efficacy of the model used in this study was verified through direct comparison of the modeled and measured data. UV-blocking hydrogel soft contact lenses reduce the MED to the human eye and therefore limit the lifetime ocular dose. These lenses are highly recommended to prevent the development of UVR-related ocular pathologic conditions.
Zimmerman, Aaron B; Marks, Amanda
2014-01-01
To report a case of neurotrophic keratitis in which scleral contact lenses improved vision from 20/100 to 20/20, however, due to poor lens care, an incident of microbial keratitis developed. A 64-year-old man with an ocular history of neurotrophic keratitis secondary to herpes simplex in each eye was successfully fit with scleral lenses. He subsequently developed microbial keratitis due to a number of risk factors. The lesion was culture negative, yet was very responsive to treatment with moxifloxacin. The lesion fully healed, and the patient did not suffer additional vision loss. This case demonstrates the ability of scleral lenses to correct visual impairments secondary to poor epithelial integrity and illustrates the importance of the practitioner providing detailed lens care instruction.
Acanthamoeba keratitis: an emerging disease gathering importance worldwide?
Lorenzo-Morales, Jacob; Martín-Navarro, Carmen María; López-Arencibia, Atteneri; Arnalich-Montiel, Francisco; Piñero, José E; Valladares, Basilio
2013-04-01
Acanthamoeba keratitis (AK) is increasingly being recognized as a severe sight-threatening ocular infection worldwide. Although contact lens wear is the leading risk factor for AK, Acanthamoeba parasites are also an important cause of keratitis in non-contact lens wearers. Diagnosis of AK is challenging, and the available treatments are lengthy and not fully effective against all strains. The pathogenesis of Acanthamoeba is still under study, and the identification of the key factors involved in this process should be useful for the development of fully effective therapies. This review focuses on recent developments on AK pathogenesis and diagnosis as well as novel strategies for the evaluation of anti-amoebic agents that could be applied in the near future against these pathogens. Copyright © 2013 Elsevier Ltd. All rights reserved.
Hypercholesterolemia-induced ocular disorder: Ameliorating role of phytotherapy.
El-Sayyad, Hassan I H; Elmansi, Ahmed A; Bakr, Eman H M
2015-01-01
The ocular region is a complex structure that allows conscious light perception and vision. It is of ecto-mesodermal origin. Cholesterol and polyunsaturated fatty acids are involved in retinal cell function; however, hypercholesterolemia and diabetes impair its function. Retinal damage, neovascularization, and cataracts are the main complications of cholesterol overload. Dietary supplementation of selected plant products can lead to the scavenging of free reactive oxygen species, thereby protecting the ocular regions from the damage of hypercholesterolemia. This review illustrates the dramatic effects of increased cholesterol levels on the ocular regions. The effect of phytotherapy is discussed in relation to the different regions of the eye, including the retina, cornea, and lens. Copyright © 2015 Elsevier Inc. All rights reserved.
Elkitkat, Rania S; El-Shazly, Amany A; Ebeid, Weam M; Deghedy, Marwa R
2018-03-01
To evaluate and correlate anthropometric, biometric, and refractive error changes in thalassemia major (TM). One hundred children with TM and another hundred healthy controls were recruited. Height, weight, body mass index (BMI), and occipitofrontal circumference (OFC) were the anthropometric parameters recorded. Full ophthalmologic examination was performed, including best-corrected visual acuity, cycloplegic refraction, slit-lamp examination, Goldmann applanation tonometry, indirect ophthalmoscopy, keratometry (K readings), and ocular biometry. Compared to controls, children with TM were shorter and lighter, with a smaller BMI (p<0.001); however, no significant difference existed in OFC. Regarding ocular biometric data, patients with thalassemia had steeper mean K readings (p = 0.03), shorter axial length (AXL) (p = 0.005), shorter vitreous chamber depth (p<0.001), and thicker crystalline lens (p<0.001) than controls. Patients with thalassemia had a significant myopic shift (p = 0.003). Multiple regression analyses only showed a significant correlation between corneal astigmatism and both weight and height (β = -0.05 and p = 0.03 and β = 0.06 and p = 0.04, respectively). Spherical equivalent was significantly correlated to K readings, lens thickness, and anterior chamber depth (p<0.0001 for all parameters). Compared to controls, children with TM have significant retardation in general and ocular growth (smaller BMI and shorter AXL). Ocular growth changes probably resulted in compensatory biometric changes (steeper corneas and thicker lenses) to reach emmetropization, with an exaggerated response and subsequent myopic shift. However, growth retardation is not directly related to ocular growth changes, myopic shift, or variations in biometric parameters.
Ocular abnormalities in mice lacking the immunoglobulin superfamily member Cdo.
Zhang, Wei; Mulieri, Philip J; Gaio, Ursula; Bae, Gyu-Un; Krauss, Robert S; Kang, Jong-Sun
2009-10-01
Vertebrate eye development requires a series of complex morphogenetic and inductive events to produce a lens vesicle centered within the bilayered optic cup and a posteriorly positioned optic stalk. Multiple congenital eye defects, including microphthalmia and coloboma, result from defects in early eye morphogenesis. Cdo is a multifunctional cell surface immunoglobulin superfamily member that interacts with and mediates signaling by cadherins and netrins to regulate myogenesis. In addition, Cdo plays an essential role in early forebrain development by functioning as coreceptor for sonic hedgehog. It is reported here that Cdo is expressed in a dynamic, but dorsally restricted, fashion during early eye development, and that mice lacking Cdo display multiple eye defects. Anomalies seen in Cdo(-/-) mice include coloboma (failure to close the optic fissure); failure to form a proper boundary between the retinal pigmented epithelium and optic stalk; defective lens formation, including failure to separate from the surface ectoderm; and microphthalmia. Consistent with this wide array of defects, developing eyes of Cdo(-/-) mice show altered expression of several regulators of dorsoventral eye patterning, including Pax6, Pax2, and Tbx5. Taken together, these findings show that Cdo is required for normal eye development and is required for normal expression of patterning genes in both the ventral and dorsal domains. The multiple eye development defects seen in Cdo(-/-) mice suggest that mutations in human Cdo could contribute to congenital eye anomalies, such as Jacobsen syndrome, which is frequently associated with ocular defects, including coloboma and Peters' anomaly.
Avetisov, S E; Polunin, G S; Sheremet, N L; Makarov, I A; Fedorov, A A; Karpova, O E; Muranov, K O; Dizhevskaia, A K; Soustov, L V; Chelnokov, E V; Bitiurin, N M; Sapogova, N V; Nemov, V V; Bodyrev, A A; Ostrovskiĭ, M A
2008-01-01
There is a potential of therapeutic action on certain stages of caractogenesis, in particular on the aggregation of water-soluble proteins of cytoplasmic lens fiber cells, giving rise to insoluble protein complexes. The effect of a combined preparation (N-acetyl carnosine and D-patethine), acting by the chaperon-like mechanism, was studied in vivo on a prolonged rat model of UV-induced cataract. The use of the combined preparation consisting of a mixture of peptides of N-acetyl carnosine and D-patethine in a ratio of 1:1 as ocular instillations and intraperitoneal injections could slow down the development of UV-induced cataract in vivo. Pathomorphological studies suggest that the combined preparation has a protective effect on lens tissue when the rat model of UV-induced cataract is employed.
Rap1 GTPase is required for mouse lens epithelial maintenance and morphogenesis
Maddala, Rupalatha; Nagendran, Tharkika; Lang, Richard A.; Morozov, Alexei; Rao, Ponugoti V.
2015-01-01
Rap1, a Ras-like small GTPase, plays a crucial role in cell-matrix adhesive interactions, cell-cell junction formation, cell polarity and migration. The role of Rap1 in vertebrate organ development and tissue architecture, however, remains elusive. We addressed this question in a mouse lens model system using a conditional gene targeting approach. While individual germline deficiency of either Rap1a or Rap1b did not cause overt defects in mouse lens, conditional double deficiency (Rap1 cKO) prior to lens placode formation led to an ocular phenotype including microphthalmia and lens opacification in embryonic mice. The embryonic Rap1 cKO mouse lens exhibited striking defects including loss of E-cadherin- and ZO-1-based cell-cell junctions, disruption of paxillin and β1-integrin-based cell adhesive interactions along with abnormalities in cell shape and apical-basal polarity of epithelium. These epithelial changes were accompanied by increased levels of α-smooth muscle actin, vimentin and N-cadherin, and expression of transcriptional suppressors of E-cadherin (Snai1, Slug and Zeb2), and a mesenchymal metabolic protein (Dihydropyrimidine dehydrogenase). Additionally, while lens differentiation was not overtly affected, increased apoptosis and dysregulated cell cycle progression were noted in epithelium and fibers in Rap1 cKO mice. Collectively these observations uncover a requirement for Rap1 in maintenance of lens epithelial phenotype and morphogenesis. PMID:26212757
Relhan, N; Jalali, S; Pehre, N; Rao, H L; Manusani, U; Bodduluri, L
2016-01-01
Purpose To characterise and differentiate posterior microphthalmos (PM) and nanophthalmos (NO) using morphometric parameters. Patients and methods Consecutive case database of patients with hyperopia >+7.00 D sphere was analysed retrospectively for clinical and biometric characterisation. Thirty-eight consecutive high-hyperopic subjects (75 eyes) with axial lengths <20.5 mm underwent uniform comprehensive ocular evaluation. Twenty-five subjects were diagnosed as PM and 13 as NO based on the horizontal corneal diameter. Parameters analysed included visual acuity, refraction, horizontal corneal diameter, anterior chamber depth, lens thickness, axial length, fundus changes, and associated ocular pathology. Primary outcome measures: ocular biometry difference between PM and NO. Secondary outcome measures: differences in associated ocular pathologies between PM and NO. Results Hyperopia ranged from +7 to +17 D and was similar in the two groups. Lens thickness was statistically more in NO than in PM group (4.53±0.75 mm vs 3.82±0.48 mm, P <0.001), whereas anterior chamber depth was more in the PM than in NO group (3.26±0.36 mm, vs 2.59±0.37 mm, P<0.001). NO had higher association with angle-closure glaucoma (66.7% vs 0%) and pigmentary retinopathy (38.5 vs 8.0%) but lesser association with macular folds (0% vs 24%) as compared with PM. NO was associated with poorer visual acuity. Conclusion PM and NO have significant differences in lens thickness, anterior chamber depth, prevalence of glaucoma, pigmentary retinopathy, macular pathology, and visual acuity while being similar in hyperopic refraction. PMID:26493039
Fugo blade-assisted lens aspiration in a case of intra- and retro-lenticular hemorrhage.
Khokhar, Sudarshan; Ganguly, Anasua; Gupta, Shikha; Sen, Seema
2013-02-01
Hemorrhage into the crystalline lens is exceedingly rare but has been described following ocular trauma [1, 2], glaucoma surgery [3-5], laser iridotomy [6], pediatric cataract surgery [7], and also in the absence of an obvious pathology [8]. We describe a case of intra- and retro-lenticular organised bleed which presented 9 years following repair of open globe injury and which was treated using fugo blade-assisted lens aspiration. The fugo blade provided adequate endocoagulation of retrolenticular blood during posterior capsulotomy and prevented undue anterior segment hemorrhage.
Ouchi, M; Kinoshita, S
2015-01-01
Purpose To evaluate the postoperative outcomes of cataract eyes complicated with coexisting ocular pathologies that underwent implantation of a refractive multifocal intraocular lens (MIOL) with a surface-embedded near section. Methods LENTIS MPlus (Oculentis GmbH) refractive MIOLs were implanted in 15 eyes with ocular pathologies other than cataract (ie, six high-myopia eyes with an axial length longer than 28 mm, two fundus albipunctatus eyes, two branch retinal-vein occlusion eyes, four glaucoma eyes (one with high myopia), and two keratoconus eyes). Uncorrected or corrected distance and near visual acuity (VA) (UDVA, UNVA, CDVA, and CNVA), contrast sensitivity, and defocus curve were measured at 1 day and 6 months postoperatively, and each patient completed a 6-month postoperative questionnaire regarding vision quality and eyeglass use. Results Thirteen eyes (87%) registered 0 or better in CDVA and 12 eyes (73%) registered better than 0 in CNVA. Contrast sensitivity in the eyes of all patients was comparable to that of normal healthy subjects. No patient required eyeglasses for distance vision, but three patients (20%) required them for near vision. No patient reported poor or very poor vision quality. Conclusion With careful case selection, sectorial refractive MIOL implantation is effective for treating cataract eyes complicated with ocular pathologies. PMID:25744442
Ouchi, M; Kinoshita, S
2015-05-01
To evaluate the postoperative outcomes of cataract eyes complicated with coexisting ocular pathologies that underwent implantation of a refractive multifocal intraocular lens (MIOL) with a surface-embedded near section. LENTIS MPlus (Oculentis GmbH) refractive MIOLs were implanted in 15 eyes with ocular pathologies other than cataract (ie, six high-myopia eyes with an axial length longer than 28 mm, two fundus albipunctatus eyes, two branch retinal-vein occlusion eyes, four glaucoma eyes (one with high myopia), and two keratoconus eyes). Uncorrected or corrected distance and near visual acuity (VA) (UDVA, UNVA, CDVA, and CNVA), contrast sensitivity, and defocus curve were measured at 1 day and 6 months postoperatively, and each patient completed a 6-month postoperative questionnaire regarding vision quality and eyeglass use. Thirteen eyes (87%) registered 0 or better in CDVA and 12 eyes (73%) registered better than 0 in CNVA. Contrast sensitivity in the eyes of all patients was comparable to that of normal healthy subjects. No patient required eyeglasses for distance vision, but three patients (20%) required them for near vision. No patient reported poor or very poor vision quality. With careful case selection, sectorial refractive MIOL implantation is effective for treating cataract eyes complicated with ocular pathologies.
Ocular disease in the guinea pig (Cavia porcellus): a survey of 1000 animals.
Williams, David; Sullivan, Ann
2010-09-01
Anecdotal evidence has suggested that guinea pigs have a high prevalence of ocular lesions. Here we undertook a survey of 1000 guinea pigs from populations of animals kept as laboratory animals, breeding show cavies, animals kept as pets and those from rescue and rehoming centers. Each animal was examined to assess for ocular abnormalities. A full ophthalmic examination was performed on each animal with direct and indirect ophthalmoscopy and with slit lamp biomicroscopy. Measurement of tear production using the Schirmer tear test 1 and intraocular pressure using the Tonopen applanation tonometer after topical anesthesia was undertaken in selected animals. Forty-five percent of animals examined had some ocular abnormality. The majority were lens lesions including 17% with cataract and 21% with subclinical lens abnormalities such as nuclear sclerosis. Other abnormalities included conjunctivitis in 4.7% and keratitis in 3.6%. Lipid deposition in conjunctiva was observed in 2.3% of guinea pigs and ciliary body heterotopic bone formation in 0.8% of animals. This study shows a high proportion of eyes with some degree of abnormality in animals otherwise considered healthy. Information on diseases of the guinea pig eye is important given the use of the species as a laboratory rodent and also the number kept as pets and show animals.
Vision Aspects of Space Flight
NASA Technical Reports Server (NTRS)
Manuel, Keith; Billica, Roger (Technical Monitor)
2000-01-01
Vision, being one of our most important senses, is critically important in the unique working environment of space flight. Critical evaluation of the astronauts visual system begins with pre-selection examinations resulting in an average of 65% of all medical disqualification's caused by ocular findings. With an average age of 42, approximately 60% of the astronaut corps requires vision correction. Further demands of the unique training and working environment of microgravity, variable lighting from very poor to extreme brightness of sunlight and exposure to extremes of electromagnetic energy results in unique eyewear and contact lens applications. This presentation will describe some of those unique eyewear and contact lens applications used in space flight and training environments. Additionally, ocular findings from 26 shuttle and 5 MIR mission post-flight examinations will be presented.
Iris reconstruction using artificial iris prosthesis for management of aniridia.
Mostafa, Yehia S; Osman, Amr A; Hassanein, Dina H; Zeid, Ashraf M; Sherif, Ahmed M
2018-01-01
To discuss the limitations and benefits of the BrightOcular prosthetic artificial iris device in management of aniridia associated with aphakia or cataract. This is a retrospective study including 5 eyes of 4 patients who underwent implantation of the BrightOcular iris prosthesis (Stellar Devices) for total or partial aniridia. The cases included 2 eyes of 1 patient with congenital aniridia associated with congenital cataract and 3 eyes with traumatic aniridia: 1 with subluxated cataractous lens and 2 with aphakia. In all cases, the iris prosthesis was implanted after a 3-piece acrylic intraocular lens was implanted. We evaluated the clinical course with a minimum follow-up period of 6 months, the intraoperative and postoperative complications, and the cosmetic satisfaction of patients. All patients had improved uncorrected distance visual acuity and best-corrected distance visual acuity. All patients had a transient corneal edema that resolved within the first postoperative week. Only the patient with congenital aniridia had a permanent increase in intraocular pressure and developed a band keratopathy throughout a 2-year follow-up period. The prosthesis was well-centered in all eyes except for one case that required scleral suture fixation after 3 months. All patients had a satisfactory cosmetic appearance. BrightOcular iris prosthesis is a safe and useful tool to correct aniridia associated with pseudophakia or aphakia. Being foldable, it is easy to be implanted through a small incision and placed in the ciliary sulcus without sutures when properly sized. Cosmetic results are satisfactory. Sizing methods should be improved.
Autofluorescence imaging of macular pigment: influence and correction of ocular media opacities
NASA Astrophysics Data System (ADS)
Sharifzadeh, Mohsen; Obana, Akira; Gohto, Yuko; Seto, Takahiko; Gellermann, Werner
2014-09-01
The healthy adult human retina contains in its macular region a high concentration of blue-light absorbing carotenoid compounds, known as macular pigment (MP). Consisting of the carotenoids lutein, zeaxanthin, and meso-zeaxanthin, the MP is thought to shield the vulnerable tissue layers in the retina from light-induced damage through its function as an optical attenuator and to protect the tissue cells within its immediate vicinity through its function as a potent antioxidant. Autofluorescence imaging (AFI) is emerging as a viable optical method for MP screening of large subject populations, for tracking of MP changes over time, and for monitoring MP uptake in response to dietary supplementation. To investigate the influence of ocular media opacities on AFI-based MP measurements, in particular, the influence of lens cataracts, we conducted a clinical trial with a large subject population (93 subjects) measured before and after cataract surgery. General AFI image contrast, retinal blood vessel contrast, and presurgery lens opacity scores [Lens Opacities Classification System III (LOCS III)] were investigated as potential predictors for image degradation. These clinical results show that lens cataracts can severely degrade the achievable pixel contrasts in the AFI images, which results in nominal MP optical density levels that are artifactually reduced. While LOCS III scores and blood vessel contrast are found to be only a weak predictor for this effect, a strong correlation exists between the reduction factor and the image contrast, which can be quantified via pixel intensity histogram parameters. Choosing the base width of the histogram, the presence or absence of ocular media opacities can be determined and, if needed, the nominal MP levels can be corrected with factors depending on the strength of the opacity.
Putting vital stains in context.
Efron, Nathan
2013-07-01
While vital staining remains a cornerstone in the diagnosis of ocular disease and contact lens complications, there are many misconceptions regarding the properties of commonly used dyes by eye-care practitioners and what is and what is not corneal staining after instillation of sodium fluorescein. Similarly, the proper use and diagnostic utility of rose Bengal and lissamine green B, the other two ophthalmic dyes commonly used for assessing ocular complications, have similarly remained unclear. Due to the limitations of vital stains for definitive diagnosis, concomitant signs and symptoms in addition to a complete patient history are required. Over the past decade, there have been many reports of a type of corneal staining--often referred to as solution-induced corneal staining (SICS)--that is observed with the use of multipurpose solutions in combination with soft lenses, more specifically silicone hydrogel lenses. Some authors believe that SICS is a sign of lens/solution incompatibility; however, new research shows that SICS may be neither a measure of lens/solution biocompatibility nor 'true' corneal staining, as that observed in pathological situations. A large component of SICS may be a benign phenomenon, known as preservative-associated transient hyperfluorescence (PATH). There is a lack of correlated signs and/or symptoms with SICS/PATH. Several properties of SICS/PATH, such as appearance and duration, differentiate it from pathological corneal staining. This paper reviews the properties of vital stains, their use and limitations in assessment of the ocular surface, the aetiology of corneal staining, characteristics of SICS/PATH that differentiate it from pathological corneal staining and what the SICS/PATH phenomenon means for contact lens-wearing patients. © 2012 The Author. Clinical and Experimental Optometry © 2012 Optometrists Association Australia.
Consequences of wear interruption for discomfort with contact lenses.
Papas, Eric B; Tilia, Daniel; Tomlinson, Daniel; Williams, Josh; Chan, Eddy; Chan, Jason; Golebiowski, Blanka
2014-01-01
To establish whether increased end-of-day discomfort during soft contact lens wear is associated with short-term changes occurring to the lens itself. Twenty-seven subjects wore hydrogel lenses (Focus Dailies; Alcon) bilaterally for 10 hours on two separate days. Comfort was reported using 1-100 numerical rating scales (1 = intolerable discomfort, 100 = lens cannot be felt). Day 1 ratings were taken before lens insertion and at 0.05, 5, and 10 hours post-insertion. Day 2 ratings occurred at similar times, but lenses were removed after the 5-hour assessment and either reinserted (n = 14) or newly replaced (n = 12). An additional rating was taken 5 minutes after re-insertion. Wear then continued to the 10-hour point. In a separate study, 24 different subjects repeated these procedures using a silicone hydrogel lens (AirOptix Aqua; Alcon) with wear taking place on 3 days to permit lens replacement to be with existing as well as new lenses in all subjects. For hydrogel lenses, comfort scores (mean ± 95% CI) reported after 10 hours were 79.4 ± 8.3 when lenses were worn un-replaced, compared with 73.2 ± 9.2 for replacement with the existing lens. When replacement was with a brand new lens, the corresponding values were 72.9 ± 10.9 (un-replaced) versus 69.2 ± 12.8 (new lens replacement). For silicone hydrogel lenses, 10-hour comfort was 90.3 ± 3.2 (un-replaced) versus 92.2 ± 2.9 (replacement with existing lens) versus 90.0 ± 3.3 (replacement with new lens). Differences between replacement conditions were not significant in any case (analysis of variance, p > 0.05). Final comfort was not influenced by replacing lenses midway through the wearing period. Comfort decrements experienced by users of these daily contact lenses towards the later part of the wearing period are not caused by changes occurring to the lenses on this time scale. Possible alternative etiological factors include a fatigue-like response in one or more ocular tissues or stimulation of ocular surface nociceptors induced by the presence of the contact lens.
Cytomegalovirus retinitis in HIV/AIDS patients.
Chiotan, C; Radu, L; Serban, R; Cornăcel, C; Cioboata, M; Anghel, A
2014-06-15
Human immunodeficiency virus (HIV) has the ability to affect any organ in the body. In 70% of HIV-infected patients ocular manifestations were observed, which in the vast majority reflect the systemic disease and may be the first sign of a disseminated infection. The purpose of this paper is to determine the prevalence and the clinical aspects of cytomegalovirus retinitis in HIV/AIDS (Acquired Immunodeficiency Syndrome) patients. The study is retrospective, conducted in the Ophthalmology Office of "Matei Bals" Infectious Diseases Hospital in Bucharest during the period August 1, 2007 - August 1, 2013. Each patient was examined thoroughly at the slit lamp biomicroscope by using a lens of 90D and a 20D lens using the indirect microscope after administration of topical mydriatics. 131 patients were followed for HIV / AIDS with posterior segment ocular involvement. 36.64% of the 131 patients having affected the posterior segment have been diagnosed with CMV retinitis. Doctors should be aware of the existence of ocular damage in HIV/AIDS and to emphasize the importance of regular ophthalmologic examination of patients with HIV/AIDS.
Five-Year PROSE Treatment for Aniridic Keratopathy.
Kojima, Takashi; Hasegawa, Asato; Nakamura, Tomoaki; Isogai, Naoki; Kataoka, Takahiro; Ichikawa, Kazuo
2016-10-01
Aniridic keratopathy is vision-threatening condition in patients with aniridia. The keratopathy occurs due to limbal stem cell deficiency. When conventional treatments fail, surgical treatments such as corneal limbal transplantation or cultivated oral mucosal epithelium transplantation are the alternatives. Here, we report our experience with the management and monitoring of the progress of a case with aniridic keratopathy treated with a scleral lens. We describe the case of a 30-year-old woman with aniridic keratopathy in both eyes. She visited our outpatient clinic for treatment of visual disturbances in her left eye, which showed a 360° invasion of the conjunctiva. Despite conventional treatment with artificial tears and autologous serum eye drops, the left eye started to suffer from recurrent corneal erosions at 19 months after the initial visit. At 50 months after the initial visit, it presented with persistent epithelial defects and decrease in vision because of the invasion of the vascularized conjunctiva with subepithelial fibrosis. Upon concluding that conventional treatment was ineffective, we tried using a scleral lens (Prosthetic Replacement of the Ocular Surface Ecosystem; PROSE). After the scleral lens treatment, the epithelial defect quickly healed, and visual acuity improved. Six years after the initial visit, the patient's right eye also started to show epithelial irregularities, which were also treated with a scleral lens. The visual acuity in the right eye too recovered, and corneal transparency was maintained until 3 years after the scleral lens treatment. The current case showed that long-term scleral lens treatment is a promising option to maintain a healthy ocular surface and visual function in eyes with aniridia caused by limbal stem cell deficiency. Early treatment with a scleral lens may be beneficial in preventing stromal scar formation in the cornea affected by aniridic keratopathy.
Single-shot dimension measurements of the mouse eye using SD-OCT.
Jiang, Minshan; Wu, Pei-Chang; Fini, M Elizabeth; Tsai, Chia-Ling; Itakura, Tatsuo; Zhang, Xiangyang; Jiao, Shuliang
2012-01-01
The authors demonstrate the feasibility and advantage of spectral-domain optical coherence tomography (SD-OCT) for single-shot ocular biometric measurement during the development of the mouse eye. A high-resolution SD-OCT system was built for single-shot imaging of the whole mouse eye in vivo. The axial resolution and imaging depth of the system are 4.5 μm (in tissue) and 5.2 mm, respectively. The system is capable of acquiring a cross-sectional OCT image consisting of 2,048 depth scans in 85 ms. The imaging capability of the SD-OCT system was validated by imaging the normal ocular growth and experimental myopia model using C57BL/6J mice. The biometric dimensions of the mouse eye can be calculated directly from one snapshot of the SD-OCT image. The biometric parameters of the mouse eye including axial length, corneal thickness, anterior chamber depth, lens thickness, vitreous chamber depth, and retinal thickness were successfully measured by the SD-OCT. In the normal ocular growth group, the axial length increased significantly from 28 to 82 days of age (P < .001). The lens thickness increased and the vitreous chamber depth decreased significantly during this period (P < .001 and P = .001, respectively). In the experimental myopia group, there were significant increases in vitreous chamber depth and axial length in comparison to the control eyes (P = .040 and P < .001, respectively). SD-OCT is capable of providing single-shot direct, fast, and high-resolution measurements of the dimensions of young and adult mouse eyes. As a result, SD-OCT is a potentially powerful tool that can be easily applied to research in eye development and myopia using small animal models. Copyright 2012, SLACK Incorporated.
Burd, H J; Wilde, G S
2016-04-01
The use of a femtosecond laser to form planes of cavitation bubbles within the ocular lens has been proposed as a potential treatment for presbyopia. The intended purpose of these planes of cavitation bubbles (referred to in this paper as 'cutting planes') is to increase the compliance of the lens, with a consequential increase in the amplitude of accommodation. The current paper describes a computational modelling study, based on three-dimensional finite element analysis, to investigate the relationship between the geometric arrangement of the cutting planes and the resulting improvement in lens accommodation performance. The study is limited to radial cutting planes. The effectiveness of a variety of cutting plane geometries was investigated by means of modelling studies conducted on a 45-year human lens. The results obtained from the analyses depend on the particular modelling procedures that are employed. When the lens substance is modelled as an incompressible material, radial cutting planes are found to be ineffective. However, when a poroelastic model is employed for the lens substance, radial cuts are shown to cause an increase in the computed accommodation performance of the lens. In this case, radial cuts made in the peripheral regions of the lens have a relatively small influence on the accommodation performance of the lens; the lentotomy process is seen to be more effective when cuts are made near to the polar axis. When the lens substance is modelled as a poroelastic material, the computational results suggest that useful improvements in lens accommodation performance can be achieved, provided that the radial cuts are extended to the polar axis. Radial cuts are ineffective when the lens substance is modelled as an incompressible material. Significant challenges remain in developing a safe and effective surgical procedure based on this lentotomy technique.
Espandar, Ladan; Caldwell, Delmar; Watson, Richard; Blanco-Mezquita, Tomas; Zhang, Shijia; Bunnell, Bruce
2014-07-01
To evaluate the therapeutic effect of human adipose-derived stem cells (hASCs) overlaid on a scleral contact lens (SCL) carrier in a rabbit model of ocular alkaline burn. After inducing alkaline burn in 11 New Zealand white rabbits, hASCs cultured on SCLs were placed on the right eye of 5 rabbits, SCLs without cells were used in 5, and no treatment was applied in 1 eye. Each eye was examined and photographed for corneal vascularization, opacities, and epithelial defect in week 1, 2, and 4 after surgery. After 1 month, rabbits were killed and the corneas were removed and cut in half for electron and light microscopy examination. Human adipose-derived stem cells were attached to SCL surface and confluent easily. Human adipose-derived stem cells on SCL eyes showed smaller epithelial defect, less corneal opacity, corneal neovascularization relative to SCL eyes. Both groups showed no symblepharon. However, the cornea in the untreated eye was melted in 2 weeks and developed severe symblepharon. Human adipose-derived stem cells on SCL can reduce inflammation and corneal haziness in severe ocular alkaline burn injury in rabbits.
Espandar, Ladan; Caldwell, Delmar; Watson, Richard; Blanco-Mezquita, Tomas; Zhang, Shijia; Bunnell, Bruce
2015-01-01
Purpose To evaluate the therapeutic effect of human adipose-derived stem cells (hASCs) overlaid on a scleral contact lens (SCL) carrier in a rabbit model of ocular alkaline burn. Materials and Methods After inducing alkaline burn in 11 New Zealand white rabbits, hASCs cultured on SCLs were placed on the right eye of 5 rabbits, SCLs without cells were used in 5, and no treatment was applied in 1 eye. Each eye was examined and photographed for corneal vascularization, opacities, and epithelial defect in week 1, 2, and 4 after surgery. After 1 month, rabbits were killed and the corneas were removed and cut in half for electron and light microscopy examination. Results Human adipose-derived stem cells were attached to SCL surface and confluent easily. Human adipose-derived stem cells on SCL eyes showed smaller epithelial defect, less corneal opacity, corneal neovascularization relative to SCL eyes. Both groups showed no symblepharon. However, the cornea in the untreated eye was melted in 2 weeks and developed severe symblepharon. Conclusion Human adipose-derived stem cells on SCL can reduce inflammation and corneal haziness in severe ocular alkaline burn injury in rabbits. PMID:24901976
Marchitti, Satori A.; Chen, Ying; Thompson, David C.; Vasiliou, Vasilis
2011-01-01
Solar ultraviolet radiation (UVR) exposes the human eye to near constant oxidative stress. Evidence suggests that UVR is the most important environmental insult leading to the development of a variety of ophthalmoheliosis disorders. UVR-induced reactive oxygen species are highly reactive with DNA, proteins and cellular membranes, resulting in cellular and tissue damage. Antioxidant defense systems present in ocular tissues function to combat reactive oxygen species and protect the eye from oxidative damage. Important enzymatic antioxidants are the superoxide dismutases, catalase, glutathione peroxidases, glutathione reductase and members of the aldehyde dehydrogenase (ALDH) superfamily. Glutathione, ascorbic and uric acids, α-tocopherol, NADPH and ferritin serve as small molecule, nonenzymatic antioxidants. Ocular tissues have high levels of these antioxidants which are essential for the maintenance of redox homeostasis in the eye and protection against oxidative damage. ALDH1A1 and ALDH3A1, present abundantly in the cornea and lens, have been shown to have unique roles in the defense against UVR and the downstream effects of oxidative stress. This review presents the properties and functions of ocular antioxidants that play critical roles in the cellular response to UVR exposure, including a focused discussion of the unique roles that the ALDH1A1 and ALDH3A1 enzymes have as multi-functional ocular antioxidants. PMID:21670692
Yokoyama, Sumi; Hamada, Nobuyuki; Hayashida, Toshiyuki; Tsujimura, Norio; Tatsuzaki, Hideo; Kurosawa, Tadahiro; Nabatame, Kuniaki; Ohguchi, Hiroyuki; Ohno, Kazuko; Yamauchi-Kawaura, Chiyo; Iimoto, Takeshi; Ichiji, Takeshi; Hotta, Yutaka; Iwai, Satoshi; Akahane, Keiichi
2017-09-25
Since the International Commission on Radiological Protection recommended reducing the occupational equivalent dose limit for the lens of the eye in 2011, there have been extensive discussions in various countries. This paper reviews the current situation in radiation protection of the ocular lens and the discussions on the potential impact of the new lens dose limit in Japan. Topics include historical changes to the lens dose limit, the current situation with occupational lens exposures (e.g., in medical workers, nuclear workers, and Fukushima nuclear power plant workers) and measurements, and the current status of biological studies and epidemiological studies on radiation cataracts. Our focus is on the situation in Japan, but we believe such information sharing will be useful in many other countries.
A scalable and deformable stylized model of the adult human eye for radiation dose assessment
NASA Astrophysics Data System (ADS)
El Basha, Daniel; Furuta, Takuya; Iyer, Siva S. R.; Bolch, Wesley E.
2018-05-01
With recent changes in the recommended annual limit on eye lens exposures to ionizing radiation, there is considerable interest in predictive computational dosimetry models of the human eye and its various ocular structures including the crystalline lens, ciliary body, cornea, retina, optic nerve, and central retinal artery. Computational eye models to date have been constructed as stylized models, high-resolution voxel models, and polygon mesh models. Their common feature, however, is that they are typically constructed of nominal size and of a roughly spherical shape associated with the emmetropic eye. In this study, we present a geometric eye model that is both scalable (allowing for changes in eye size) and deformable (allowing for changes in eye shape), and that is suitable for use in radiation transport studies of ocular exposures and radiation treatments of eye disease. The model allows continuous and variable changes in eye size (axial lengths from 20 to 26 mm) and eye shape (diopters from ‑12 to +6). As an explanatory example of its use, five models (emmetropic eyes of small, average, and large size, as well as average size eyes of ‑12D and +6D) were constructed and subjected to normally incident beams of monoenergetic electrons and photons, with resultant energy-dependent dose coefficients presented for both anterior and posterior eye structures. Electron dose coefficients were found to vary with changes to both eye size and shape for the posterior eye structures, while their values for the crystalline lens were found to be sensitive to changes in only eye size. No dependence upon eye size or eye shape was found for photon dose coefficients at energies below 2 MeV. Future applications of the model can include more extensive tabulations of dose coefficients to all ocular structures (not only the lens) as a function of eye size and shape, as well as the assessment of x-ray therapies for ocular disease for patients with non-emmetropic eyes.
Conditional ablation of the Notch2 receptor in the ocular lens
Saravanamuthu, Senthil S.; Le, Tien T.; Gao, Chun Y.; Cojocaru, Radu I.; Pandiyan, Pushpa; Liu, Chunqiao; Zhang, Jun; Zelenka, Peggy S.; Brown, Nadean L.
2011-01-01
Notch signaling is essential for proper lens development, however the specific requirements of individual Notch receptors have not been investigated. Here we report the lens phenotypes of Notch2 conditionally mutant mice, which exhibited severe microphthalmia, reduced pupillary openings, disrupted fiber cell morphology, eventual loss of the anterior epithelium, fiber cell dysgenesis, denucleation defects, and cataracts. Notch2 mutants also had persistent lens stalks as early as E11.5, and aberrant DNA synthesis in the fiber cell compartment by E14.5. Gene expression analyses showed that upon loss of Notch2, there were elevated levels of the cell cycle regulators Cdkn1a (p21Cip1), Ccnd2 (CyclinD2), and Trp63 (p63) that negatively regulates Wnt signaling, plus down-regulation of Cdh1 (E-Cadherin). Removal of Notch2 also resulted in an increased proportion of fiber cells, as was found in Rbpj and Jag1 conditional mutant lenses. However, Notch2 is not required for AEL proliferation, suggesting that a different receptor regulates this process. We found that Notch2 normally blocks lens progenitor cell death. Overall, we conclude that Notch2-mediated signaling regulates lens morphogenesis, apoptosis, cell cycle withdrawal, and secondary fiber cell differentiation. PMID:22173065
Intraocular and crystalline lens protection from ultraviolet damage.
Sliney, David H
2011-07-01
Although the risks of excess solar ultraviolet (UV) exposure of the skin are well recognized, the need for eye protection is frequently overlooked, or when sunglasses are also recommended, specific guidance is wrong or is not explained. Guidance from the World Health Organization at its InterSun webpage advises people to wear "wrap-around" sunglasses under many conditions. The objective of this study was to examine the need for UV filtration in prescription lenses, contact lenses, and sunglasses. The geometry of UV exposure of both eyes, solar position, ground reflection, pupil size, and lid opening were studied. Because an accurate determination of cumulative ocular exposure is difficult, the cornea itself can serve as a biologic dosimeter, because photokeratitis is not experienced on a daily basis but does under certain ground-surface and sunlight conditions. From a knowledge of the UV-threshold dose required to produce photokeratitis, we have an upper level of routine ocular exposure to ambient UV. From ambient UV measurements and observed photokeratitis, the upper limits of UV exposure of the crystalline lens or an intraocular lens implant are estimated. The risk of excess UV exposure of the germinative cells of the lens is greatest from the side. Sunglasses can actually increase UV exposure of the germinative region of the crystalline lens and the corneal limbus by disabling the eyes' natural protective mechanisms of lid closure and pupil constriction! The level of UV-A risk is difficult to define. Proper UV-absorbing contact lenses offer the best mode for filtering needless exposure of UV radiation of the lens and limbus.
Yang, Mei; Yang, Yangfan; Lei, Ming; Ye, Chengtian; Zhao, Chunshun; Xu, Jiangang; Wu, Kaili; Yu, Minbin
2016-11-01
Pirfinedone (PFD) is a novel agent which has the potential to prevent scarring in the eyes. The 0.5% PFD eye drops exhibits poor bioavailability. Whereas, the feasibility of using contact lens as ocular drug delivery device initiated novel possibilities. To evaluate the delivery of PFD by soft contact lens (SCL) in vivo, we screened the most suitable lens material for PFD among various commercially available SCL materials in vitro. Firstly, 11 different SCLs (-1.00 diopter) were respectively soaked in 2 ml of 0.05% PFD-loading solution for 24 h to fully absorb drug, and then placed in fresh phosphate buffered saline (PBS) to release the drug. PFD concentration in PBS was determined by ultraviolet absorbance at 310 nm. Secondly, by immersing in 2 ml of 0.5% PFD eye drops for 24 h, the polymacon lens (0.00 diopter) was then placed on the cornea of New Zealand rabbits. PFD concentrations were detected by high performance liquid chromatography (HPLC) in tears, aqueous humor, conjunctiva, cornea, and sclera at different time points. PFD showed some affinity for pHEMA-based lenses and the polymacon lens more slowly released more amount of PFD than any other lens in vitro (p < 0.001). Compared with eye drops, drug-loaded SCLs greatly enhanced the retention time and concentrations of PFD in cornea and aqueous humor and consequently improved the bioavailability of PFD. Polymacon-based SCL is probably a promising vehicle to be an effective ophthalmic delivery system for PFD.
Meteyer, C.U.; Dubielzig, R.D.; Dein, F.J.; Baeten, L.A.; Moore, M.K.; Jehl, J.R.; Wesenberg, K.E.
1997-01-01
Cause of mortality was studied in waterfowl in hypersaline playa lakes of southeast New Mexico during spring and fall migration. Mortality was not common in wild ducks resting on the playas during good weather. However, when birds remained on the lakes for prolonged periods of time, such as during experimental trials and stormy weather, a heavy layer of salt precipitated on their feathers. Sodium toxicity was the cause of death for all experimental mallards housed on playa water and for 50% of the wild waterfowl found moribund or dead during the spring of 1995. Gross lesions included heavy salt precipitation on the feathers, ocular lens opacities, deeply congested brains, and dilated, thin-walled, fluid-filled cloacae. Microscopic lesions in the more severely affected birds included liquefaction of ocular lens cortex with lens fiber swelling and multifocal to diffuse ulcerative conjunctivitis with severe granulocytic inflammation, edema, and granulocytic vasculitis resulting in thrombosis. Inflammation similar to that seen in the conjunctiva occasionally involved the mucosa of the mouth, pharynx, nasal turbinates, cloaca, and bursa. Transcorneal movement of water in response to the hypersaline conditions on the playa lakes or direct contact with salt crystals could induce anterior segment dehydration of the aqueous humor and increased osmotic pressure on the lens, leading to cataract formation.
Pediatric ocular injury secondary to a Burmese python bite.
Behrens, Alice W; Jones, Maria H; Lowery, R Scott
2018-03-22
We report the case of a 6-year-old girl with a penetrating ocular injury caused by a Burmese python. She received intravenous cefazolin before presenting and was treated thereafter with daily topical antibiotics and atropine. Six weeks after injury, she underwent cataract extraction and sulcus implantation of an intraocular lens and iris synechiolysis, with postoperative patching. Final visual outcome was excellent despite no globe repair was performed. Published by Elsevier Inc.
Müller stem cell dependent retinal regeneration.
Chohan, Annu; Singh, Usha; Kumar, Atul; Kaur, Jasbir
2017-01-01
Müller Stem cells to treat ocular diseases has triggered enthusiasm across all medical and scientific communities. Recent development in the field of stem cells has widened the prospects of applying cell based therapies to regenerate ocular tissues that have been irreversibly damaged by disease or injury. Ocular tissues such as the lens and the retina are now known to possess cell having remarkable regenerative abilities. Recent studies have shown that the Müller glia, a cell found in all vertebrate retinas, is the primary source of new neurons, and therefore are considered as the cellular basis for retinal regeneration in mammalian retinas. Here, we review the current status of retinal regeneration of the human eye by Müller stem cells. This review elucidates the current status of retinal regeneration by Müller stem cells, along with major retinal degenerative diseases where these stem cells play regenerative role in retinal repair and replacement. Copyright © 2016. Published by Elsevier B.V.
Suchecki, Jeanine K; Donshik, Peter; Ehlers, William H
2003-09-01
Complications associated with contact lenses range from mild to severe and occur with all lens modalities. Contact lens wear can cause a change in corneal physiology, which can lead to epithelial, stromal, and endothelial compromise. Other complications include lens deposition, allergic conjunctivitis, giant papillary conjunctivitis, peripheral infiltrates, microbial keratitis, and neovascularization. Pre-existing conditions can contribute to these complications, or they can occur in association with contact lens wear and care regimens. Patient-related factors, such as alteration of the recommended wearing or replacement schedules and noncompliance with recommended contact lens care regimens for economic reasons, convenience, or in error, contribute to contact lens-related complications and have led to difficulty in accurate determination of complication rates among the various lens wear modalities. Complications may require discontinuation of contact lenses, topical therapy, and changes in contact lens wearing schedules, materials, and care solutions. On initial lens fitting and follow-up evaluations, practitioners should review contact lens replacement and cleaning regimens with patients and discuss complications. To avoid serious complications, patients should be reminded to remove their contact lenses as soon as ocular irritation occurs, and to call their eye care practitioner immediately if symptoms persist.
Conjunctival Goblet Cell Function: Effect of Contact Lens Wear and Cytokines
García-Posadas, Laura; Contreras-Ruiz, Laura; Soriano-Romaní, Laura; Dartt, Darlene A.; Diebold, Yolanda
2015-01-01
This review focuses on conjunctival goblet cells and their essential function in the maintenance of eye health. The main function of goblet cells is to produce and secrete mucins that lubricate the ocular surface. An excess or a defect in those mucins leads to several alterations that makes goblet cells central players in maintaining the proper mucin balance and ensuring the correct function of ocular surface tissues. A typical pathology that occurs with mucous deficiency is dry eye disease, whereas the classical example of mucous hyperproduction is allergic conjunctivitis. In this review we analyze how goblet cell number and function can be altered in these diseases and in contact lens wearers. We found that most published studies focused exclusively on goblet cell number. However, recent advances have demonstrated that, along with mucin secretion, goblet cells are also able to secrete cytokines and respond to them. We describe the effect of different cytokines on goblet cell proliferation and secretion. We conclude that it is important to further explore the effect of contact lens wear and cytokines on conjunctival goblet cell function. PMID:26067396
Application of the polychromatic defocus transfer function to multifocal lenses.
Schwiegerling, Jim; Choi, Junoh
2008-11-01
To model the performance of multifocal lenses in polychromatic lighting. The defocus transfer function (DTF) is a mathematical technique for illustrating the optical transfer function for all levels of defocus at a given wavelength. A polychromatic version of the DTF is developed that accounts for changes in cutoff frequency, reduction in diffraction efficiency, ocular chromatic aberration, and photoreceptor spectral sensitivity. The differences between the monochromatic and polychromatic DTF are illustrated with a diffractive multifocal intraocular lens. Polychromatic analysis shows an increase in depth of field of diffractive lenses relative to assessment at a single wavelength. The polychromatic DTF is a useful tool for analyzing presbyopia treatments under "white-light" viewing conditions and provides feedback to lens designers on anticipated performance.
UV-B-induced DNA damage and repair in the mouse lens.
Mesa, Rosana; Bassnett, Steven
2013-10-17
Epidemiologic studies have linked UV-B exposure to development of cortical cataracts, but the underlying molecular mechanism(s) is unresolved. Here, we used a mouse model to examine the nature and distribution of DNA photolesions produced by ocular UV-B irradiation. Anesthetized mice, eye globes, or isolated lenses were exposed to UV-B. Antibodies specific for 6-4 photoproducts (6-4 PPs) or cyclobutane pyrimidine dimers (CPDs) were used to visualize DNA adducts. Illumination of intact globes with UV-B-induced 6-4 PP and CPD formation in cells of the cornea, anterior iris, and central lens epithelium. Photolesions were not detected in retina or lens cells situated in the shadow of the iris. Photolesions in lens epithelial cells were produced with radiant exposures significantly below the minimal erythemal dose. Lens epithelial cells rapidly repaired 6-4 PPs, but CPD levels did not markedly diminish, even over extended postirradiation recovery periods in vitro or in vivo. The repair of 6-4 PPs did not depend on the proliferative activity of the epithelial cells, since the repair rate in the mitotically-active germinative zone (GZ) was indistinguishable from that of quiescent cells in the central epithelium. Even relatively modest exposures to UV-B produced 6-4 PP and CPD photolesions in lens epithelial cells. Cyclobutane pyrimidine dimer lesions were particularly prevalent and were repaired slowly if at all. Studies on sun-exposed skin have established a causal connection between photolesions and so-called UV-signature mutations. If similar mechanisms apply in the lens, it suggests that somatic mutations in lens epithelial cells may contribute to the development of cortical cataracts.
Association between Refractive Errors and Ocular Biometry in Iranian Adults
Hashemi, Hassan; Khabazkhoob, Mehdi; Emamian, Mohammad Hassan; Shariati, Mohammad; Miraftab, Mohammad; Yekta, Abbasali; Ostadimoghaddam, Hadi; Fotouhi, Akbar
2015-01-01
Purpose: To investigate the association between ocular biometrics such as axial length (AL), anterior chamber depth (ACD), lens thickness (LT), vitreous chamber depth (VCD) and corneal power (CP) with different refractive errors. Methods: In a cross-sectional study on the 40 to 64-year-old population of Shahroud, random cluster sampling was performed. Ocular biometrics were measured using the Allegro Biograph (WaveLight AG, Erlangen, Germany) for all participants. Refractive errors were determined using cycloplegic refraction. Results: In the first model, the strongest correlations were found between spherical equivalent with axial length and corneal power. Spherical equivalent was strongly correlated with axial length in high myopic and high hyperopic cases, and with corneal power in high hyperopic cases; 69.5% of variability in spherical equivalent was attributed to changes in these variables. In the second model, the correlations between vitreous chamber depth and corneal power with spherical equivalent were stronger in myopes than hyperopes, while the correlations between lens thickness and anterior chamber depth with spherical equivalent were stronger in hyperopic cases than myopic ones. In the third model, anterior chamber depth + lens thickness correlated with spherical equivalent only in moderate and severe cases of hyperopia, and this index was not correlated with spherical equivalent in moderate to severe myopia. Conclusion: In individuals aged 40-64 years, corneal power and axial length make the greatest contribution to spherical equivalent in high hyperopia and high myopia. Anterior segment biometric components have a more important role in hyperopia than myopia. PMID:26730304
Ocular hazards of light sources: review of current knowledge.
Ham, W T
1983-02-01
Retinal damage is the most important hazard from light. There are three types of retinal damage classified as structural, thermal and photochemical; damage type depends on wavelength, power level and exposure time. Photochemical damage from blue light produces solar retinitis and is postulated to accelerate aging which leads to senile macular degeneration. The lens protects the retina from blue light and near ultraviolet (UV) but at the expense of cataractogenesis. Lens removal exposes retina to near UV that is six times more dangerous than blue light. Filters are recommended to protect lens and retina from blue light and near UV.
Guillon, Michel; Maïssa, Cécile
2010-12-01
The objective of the investigation was to show that, because of their overall properties, Acuvue® Oasys™ with Hydraclear™ Plus brand (senofilcon A) silicone hydrogel contact lenses achieve excellent ocular tissue tolerance during long-term extended wear. The investigation was a 2-year, prospective, extended wear investigation of senofilcon A silicone hydrogel contact lenses worn for up to 6 nights without removal. The 2-year results compared with the subjects' baseline ocular statuses on entering the study revealed: The quantification of the effects on the ocular tissues of 2 years of extended wear of senofilcon A, by mainly previously successful daily soft contact lens wearers, found an excellent biocompatibility. The results support the hypothesis that senofilcon A contact lenses, when worn on a 6-night/7-day extended wear regimen, maintain excellent long-term ocular tissue tolerance. Copyright © 2010 American Optometric Association. Published by Elsevier Inc. All rights reserved.
Ocular autofluorescence in diabetes mellitus. A review.
Calvo-Maroto, Ana M; Perez-Cambrodi, Rafael J; Garcia-Lazaro, Santiago; Ferrer-Blasco, Teresa; Cerviño, Alejandro
2016-09-01
Diabetes mellitus is a metabolic disease with a considerable impact on healthcare owing to its increased prevalence and high mortality rate. Structural, morphological, and physiological changes in each of the ocular components have been described in detail. Autofluorescence has been described as a good indicator of metabolic activity. The aim of the present review is to provide an overview of ocular endogenous fluorophores in the cornea, the crystalline lens, and the retinal pigment epithelium, the effects of diabetes mellitus and therefore the potential of autofluorescence assessment for screening and monitoring changes in diabetic patients. © 2016 Ruijin Hospital, Shanghai Jiaotong University School of Medicine and John Wiley & Sons Australia, Ltd.
Pekel, Gökhan; Cetin, Ebru Nevin; Acer, Semra; Yagci, Ramazan; Altintas, Seher; Ongun, Gülin Tugba
2014-06-01
To evaluate the effects of chronic tobacco smoking on lens nucleus by Pentacam HR lens densitometry (LD) in young adults. Prospective cross-sectional case series. Thirty subjects (23 M, 7 F) who were chronic cigarette smokers (≥10 cigarettes/day for at least 2 years) (group 1) and another 30 subjects (23 M, 7 F) who did not smoke (group 2), were included in this study. The patients were matched for age and sex between the groups. The exclusion criteria were any history of ocular surgery, any systemic disorders and any ocular diseases except for mild refractive disorders. Lens densitometry measurements were done with the Pentacam HR (Oculus, Wetzlar, Germany). The Schirmer test and pachymetry measurements were also performed. Mean age of the patients for both groups was 28.90 ± 8.20 years (range: 18-40 years). Mean lens densitometry (LD) measurements of Group 1 (chronic cigarette smoking group) were higher than those of Group 2 (control group) in all LD techniques; however only mean "peak" LD measurements showed a statistically significant difference between these two groups (Group 1: 8.67 ± 0.61, Group 2: 8.44 ± 0.70, p = 0.04). The mean Schirmer test value was 12.43 ± 5.60 mm in Group 1 and 13.00 ± 4.26 mm in Group 2 (p = 0.55). The mean central corneal thickness (CCT) value was 564.23 ± 34.61 µm in Group 1 and 550.47 ± 32.94 µm in Group 2 (p = 0.03). The Pentacam HR LD seems to be an important option for the evaluation of lens nucleus in young adults, because it gives objective and quantitative data. Although chronic smoking increases lens nucleus density in young adults, the effect is not statistically significant when compared with the control group.
Banerjee, A; Emanuel, K; Parafina, J; Bagchi, M
1992-10-01
A water soluble growth inhibitor was isolated from the mammalian ocular iris-ciliary complex. The molecular weight of this protein is 10 kD or lower as determined by ultrafiltration fractionation. The iris-ciliary (IC) complex water soluble protein(s) significantly inhibits synthesis of lower molecular weight proteins of the epithelial cells of the organ cultured mammalian ocular lens. It was also found that this inhibitory effect of IC is mediated via the structural organization of the lens. Monolayer cultures of the lens epithelial cells exposed to IC did not manifest any inhibition of their protein synthesis. Moreover, these tissue cultured lens epithelial (TCLE) cells showed a significant increase in their protein synthetic activities in response to the presence of IC factors in the culture medium. It is postulated that the IC activity is modulated via either the lens capsule, an extracellular matrix, or due to the specific organization of the intact lens. The specific effects of IC on the cytoskeletal organization and synthesis in the organ cultured lens epithelial (OCLE) and TCLE cells were also examined. Both groups, treated with IC factors, manifested significant alterations in their protein synthetic activities and cytoskeletal architecture. The 3H-leucine incorporation experiments showed that alpha-actin and alpha-tubulin synthesis is partially inhibited by IC factors in OCLE cells but vimentin synthesis is not, whereas in TCLE cells all of them showed increased synthesis in response to IC factors. Turnover rates of these proteins in both OCLE and TCLE cells were also computed. The immunofluorescence and microscopic evaluation of OCLE and TCLE cells exposed to IC factors illustrated significant alteration in the cytoarchitecture of the filaments. We demonstrate that an inhibitor(s) molecule of 10 kD or lower size isolated from IC inhibited protein synthesis of OCLE cells and stimulated protein synthesis in TCLE cells. The IC factor also affects the synthesis and organization of cytoskeletal filaments of both the OCLE and TCLE cells.
Takahide, Kikuchi; Parker, Pablo M.; Wu, Michael; Hwang, William Y.K.; Carpenter, Paul A.; Moravec, Carina; Stehr, Barbara; Martin, Paul J.; Rosenthal, Perry; Forman, Stephen J.; Flowers, Mary E.D.
2007-01-01
Keratoconjunctivitis sicca (KCS) occurs in 40-60 % of patients with chronic graft-versus-host-disease (GVHD) after allogeneic hematopoietic cell transplantation. While immunosuppressive therapy is the primary treatment of chronic GVHD, ocular symptoms require measures to improve ocular lubrication, decrease inflammation and maintain mucosal integrity. The liquid corneal bandage provided by a fluid-ventilated, gas-permeable scleral lens (SL) has been effective in mitigating symptoms and resurfacing corneal erosions in patients with KCS related to causes other than chronic GVHD. We report outcomes in 9 consecutive patients referred for SL fitting for chronic GVHD-related severe KCS that was refractory to standard treatments. All patients reported improvement of ocular symptoms and reduced the use of topical lubricants after SL fitting resulting from decrease evaporation. No serious adverse events or infections attributable to the SL occurred. The median Ocular Surface Disease Index improved from 81 (75-100) to 21 (6-52) within 2 weeks after SL fitting and was 12 (2-53) at the time of last contact, 1-23 months (median, 8.0) after SL fitting. Disability related to KCS resolved in 7 patients after SL fitting. The use of SL appears to be safe and effective in patients with severe chronic GVHD-related KCS refractory to conventional therapies. PMID:17697963
The effect of successful contact lens wear on mucosal immunity of the eye.
McClellan, K A; Cripps, A W; Clancy, R L; Billson, F A
1998-08-01
This study aimed to assess the effect of contact lens wear on the mucosal defenses of the outer eye against infection. A case-controlled study of daily contact lens wearers in their initial 6 months of contact lens wear. Contact lens wearers (mean age, 23.1 years; 47 subjects) were compared with age-matched control subjects (mean age, 24.7 years; 44 subjects). Outer eye defenses were studied by assay of tear constituents and quantitative conjunctival microbiology. Antimicrobial activity of tears was studied by assay of total immunoglobulin A (IgA), IgA isotype-specific antibodies reactive with Escherichia coli, Haemophilus influenzae, Staphylococcus epidermidis, albumin and lysozyme, and the ocular surface microbial load determined using quantitative microbiology of the conjunctival sac. The IgA isotype-specific antibodies reactive with E. coli (P = 0.03) and S. epidermidis (P = 0.068) were lower in contact lens wearers, but antibody:albumin ratios were not significantly different in the two groups. Contact lens wear also had no significant effect on tear IgA, albumin, or lysozyme or its ratios with albumin. Bacterial numbers and colonization rates for coagulase-negative staphylococci were greater in contact lens wearers than in age-matched control subjects. Corynebacterium sp. and non-Enterobacteriaceae (P = 0.007) were isolated more frequently and in greater numbers from contact lens wearers. Colonization rates were increased for Corynebacterium sp., but non-Enterobacteriaceae were transient. In both daily contact lens wearers and age-matched control subjects, most conjunctival flora were transient rather than colonizing, and no subject developed an outer eye infection during the study. These results suggest that daily contact lens wear does not significantly alter the mucosal defenses of the outer eye that function to eliminate organisms from the conjunctival sac and prevent outer eye infection.
Ohlmann, Andreas; Scholz, Michael; Goldwich, Andreas; Chauhan, Bharesh K; Hudl, Kristiane; Ohlmann, Anne V; Zrenner, Eberhart; Berger, Wolfgang; Cvekl, Ales; Seeliger, Mathias W; Tamm, Ernst R
2005-02-16
Norrie disease is an X-linked retinal dysplasia that presents with congenital blindness, sensorineural deafness, and mental retardation. Norrin, the protein product of the Norrie disease gene (NDP), is a secreted protein of unknown biochemical function. Norrie disease (Ndp(y/-)) mutant mice that are deficient in norrin develop blindness, show a distinct failure in retinal angiogenesis, and completely lack the deep capillary layers of the retina. We show here that the transgenic expression of ectopic norrin under control of a lens-specific promoter restores the formation of a normal retinal vascular network in Ndp(y/-) mutant mice. The improvement in structure correlates with restoration of neuronal function in the retina. In addition, lenses of transgenic mice with ectopic expression of norrin show significantly more capillaries in the hyaloid vasculature that surrounds the lens during development. In vitro, lenses of transgenic mice in coculture with microvascular endothelial cells induce proliferation of the cells. Transgenic mice with ectopic expression of norrin show more bromodeoxyuridine-labeled retinal progenitor cells at embryonic day 14.5 and thicker retinas at postnatal life than wild-type littermates, indicating a putative direct neurotrophic effect of norrin. These data provide direct evidence that norrin induces growth of ocular capillaries and that pharmacologic modulation of norrin might be used for treatment of the vascular abnormalities associated with Norrie disease or other vascular disorders of the retina.
The use of contact lenses in low vision rehabilitation: optical and therapeutic applications.
Vincent, Stephen J
2017-09-01
Ocular pathology that manifests at an early age has the potential to alter the vision-dependent emmetropisation mechanism, which co-ordinates ocular growth throughout childhood. The disruption of this feedback mechanism in children with congenital or early-onset visual impairment often results in the development of significant ametropia, including high levels of spherical refractive error, astigmatism and anisometropia. This review examines the use of contact lenses as a refractive correction, low vision aid and therapeutic intervention in the rehabilitation of patients with bilateral, irreversible visual loss due to congenital ocular disease. The advantages and disadvantages of the use of contact lenses for increased magnification (telescopes and microscopes) or field expansion (reverse telescopes) are discussed, along with the benefits and practical considerations for the correction of pathological high myopia. The historical and present use of therapeutic tinted contact lenses to reduce photosensitivity and nystagmus in achromatopsia, albinism and aniridia are also presented, including clinical considerations for the contact lens practitioner. In addition to the known optical benefits in comparison to spectacles for high levels of ametropia (an improved field of view for myopes and fewer inherent oblique aberrations), contact lenses may be of significant psycho-social benefit for patients with low vision, due to enhanced cosmesis and reduced conspicuity and potential related effects of improved self-esteem and peer acceptance. The contact lens correction of patients with congenital vision impairment can be challenging for both practitioner and patient but should be considered as a potential optical or therapeutic solution in modern low vision rehabilitation. © 2017 Optometry Australia.
Rymer, Jodi; Choh, Vivian; Bharadwaj, Shrikant; Padmanabhan, Varuna; Modilevsky, Laura; Jovanovich, Elizabeth; Yeh, Brenda; Zhang, Zhan; Guan, Huanxian; Payne, W; Wildsoet, Christine F
2007-10-01
Albinism is associated with a variety of ocular anomalies including refractive errors. The purpose of this study was to investigate the ocular development of an albino chick line. The ocular development of both albino and normally pigmented chicks was monitored using retinoscopy to measure refractive errors and high frequency A-scan ultrasonography to measure axial ocular dimensions. Functional tests included an optokinetic nystagmus paradigm to assess visual acuity, and flash ERGs to assess retinal function. The underlying genetic abnormality was characterized using a gene microarray, PCR and a tyrosinase assay. The ultrastructure of the retinal pigment epithelium (RPE) was examined using transmission electron microscopy. PCR confirmed that the genetic abnormality in this line is a deletion in exon 1 of the tyrosinase gene. Tyrosinase gene expression in isolated RPE cells was minimally detectable, and there was minimal enzyme activity in albino feather bulbs. The albino chicks had pink eyes and their eyes transilluminated, reflecting the lack of melanin in all ocular tissues. All three main components, anterior chamber, crystalline lens and vitreous chamber, showed axial expansion over time in both normal and albino animals, but the anterior chambers of albino chicks were consistently shallower than those of normal chicks, while in contrast, their vitreous chambers were longer. Albino chicks remained relatively myopic, with higher astigmatism than the normally pigmented chicks, even though both groups underwent developmental emmetropization. Albino chicks had reduced visual acuity yet the ERG a- and b-wave components had larger amplitudes and shorter than normal implicit times. Developmental emmetropization occurs in the albino chick but is impaired, likely because of functional abnormalities in the RPE and/or retina as well as optical factors. In very young chicks the underlying genetic mutation may also contribute to refractive error and eye shape abnormalities.
Noninvasive Continuous Monitoring of Tear Glucose Using Glucose-Sensing Contact Lenses.
Ascaso, Francisco J; Huerva, Valentín
2016-04-01
: The incidence of diabetes mellitus is dramatically increasing in the developed countries. Tight control of blood glucose concentration is crucial to diabetic patients to prevent microvascular complications. Self-monitoring of blood glucose is widely used for controlling blood glucose levels and usually performed by an invasive test using a portable glucometer. Many technologies have been developed over the past decades with the purpose of obtaining a continuous physiological glycemic monitoring. A contact lens is the ideal vehicle for continuous tear glucose monitoring of glucose concentration in tear film. There are several research groups that are working in the development of contact lenses with embedded biosensors for continuously and noninvasively monitoring tear glucose levels. Although numerous aspects must be improved, contact lens technology is one step closer to helping diabetic subjects better manage their condition, and these contact lenses will be able to measure the level of glucose in the wearer's tears and communicate the information to a mobile phone or computer. This article reviews studies on ocular glucose and its monitoring methods as well as the attempts to continuously monitor the concentration of tear glucose by using contact lens-based sensors.
Tomás-Juan, Javier; Murueta-Goyena Larrañaga, Ane
2015-01-01
Presbyopia occurs in the aging eye due to changes in the ciliary muscle, zonular fibers, crystalline lens, and an increased lens sclerosis. As a consequence, the capacity of accommodation decreases, which hampers to focus near objects. With the aim of restoring near vision, different devices that produce multiple focuses have been developed and introduced. However, these devices are still unable to restore accommodation. In order to achieve that goal, dual-optic accommodating Intraocular Lenses have been designed, whose anterior optic displaces axially to increase ocular power, and focus near objects. Although dual-optic accommodating IOLs are relatively new, their outcomes are promising, as they provide large amplitudes of accommodation and a greater IOL displacement than single-optic accommodating IOLs. The outcomes show comfortable near vision, higher patients' satisfaction rates, and minimal postoperative complications like Posterior Capsular Opacification and Anterior Capsular Opacification, due to their design and material. Copyright © 2014. Published by Elsevier Espana.
Intraocular Lens Use in an Astronaut During Long Duration Spaceflight.
Mader, Thomas H; Gibson, C Robert; Schmid, Josef F; Lipsky, William; Sargsyan, Ashot E; Garcia, Kathleen; Williams, Jeffrey N
2018-01-01
The purpose of this paper is to report the first use of an intraocular lens (IOL) in an astronaut during long duration spaceflight (LDSF). An astronaut developed a unilateral cataract and underwent phacoemulsification with insertion of an acrylic IOL. Approximately 15 mo later he flew on a Soyuz spacecraft to the International Space Station (ISS), where he successfully completed a 6-mo mission. Ocular examination, including ultrasound (US), was performed before, during, and after his mission and he was questioned regarding visual changes during each portion of his flight. We documented no change in IOL position during his space mission. This astronaut reported excellent and stable vision during liftoff, entry into microgravity (MG), 6 mo on the ISS, descent, and landing. Our results suggest that modern IOLs are stable, effective, and well tolerated during LDSF.Mader TH, Gibson CR, Schmid JF, Lipsky W, Sargsyan AE, Garcia K, Williams JN. Intraocular lens use in an astronaut during long duration spaceflight. Aerosp Med Hum Perform. 2018; 89(1):63-65.
Dry Eye Treatment Based on Contact Lens Drug Delivery: A Review.
Guzman-Aranguez, Ana; Fonseca, Begoña; Carracedo, Gonzalo; Martin-Gil, Alba; Martinez-Aguila, Alejandro; Pintor, Jesús
2016-09-01
Dry eye disease affects a substantial segment of the word population with increasing frequency. It is a multifactorial disease of the ocular surface and tear film, which causes ocular discomfort, visual disturbances, and tear instability with potential damage to the cornea and conjunctiva. Because of its multifactorial etiology, the use of different pharmacological treatment for dry eye treatment has been proposed, which include anti-inflammatory molecules, lubricants or comfort agents, and secretagogues. However, in some cases these pharmacological approaches only relieve symptoms temporarily, and consequently, eye care professionals continue to have difficulties managing dry eye. To improve pharmacological therapy that allows a more efficient and long-term action, effective ocular drug delivery of the currently available drugs for dry eye treatment is required. Contact lenses are emerging as alternative ophthalmic drugs delivery systems that provide an increased residence time of the drug at the eye, thus leading to enhanced bioavailability and more convenient and efficacious therapy. In this article, we reviewed the different techniques used to prepare contact lens-based drug delivery systems and focused on articles that describe the delivery of compounds for dry eye treatment through contact lenses.
Does blunt ocular trauma induce corneal astigmatism?
Akinci, Arsen; Ileri, Dilek; Polat, Sibel; Can, Cigdem; Zilelioglu, Orhan
2007-06-01
To determine the effect of blunt ocular trauma on refractive astigmatism. Eighty-six eyes of 86 patients with known previous refractive status exposed to blunt ocular trauma were included in the study. Trauma-induced astigmatism (TIA) was calculated using vector analysis. In eyes with TIA, central corneal thickness was assessed by ultrasound pachymetry, and corneal topographies were obtained. Anterior-chamber angles were examined by Goldmann 3-mirror lens to find microhemorrhages, scarring, or recession. Patients were followed up between 8 and 12 months (average, 9.2 months). In 18 eyes (21%), TIA was detected. Six (7%) of these eyes had lenticular astigmatism caused by traumatic lens subluxation. In the remaining 12 eyes (14%), corneal topography showed regular astigmatic patterns, which were symmetrical in 3 eyes and asymmetric in the remaining 9. The etiologic factor was a game marble in 6 eyes and a stone in the remaining 6. The mean central corneal thickness was 535.75 microm (range, 498-570 microm) in these 12 eyes. In 9 of these 12 eyes, recession or scarring in the anterior-chamber angle was detected at 1 edge of the steepest axis. Blunt trauma can induce astigmatism. Hard and small objects are more likely to induce astigmatism.
NASA Astrophysics Data System (ADS)
Hammer, Daniel X.; Noojin, Gary D.; Thomas, Robert J.; Stolarski, David J.; Rockwell, Benjamin A.; Welch, Ashley J.
1999-06-01
Spectrally resolved white-light interferometry (SRWLI) was used to measure the wavelength dependence of refractive index (i.e., dispersion) for various ocular components. The accuracy of the technique was assessed by measurement of fused silica and water, the refractive indices of which have been measured at several different wavelengths. The dispersion of bovine and rabbit aqueous and vitreous humor was measured from 400 to 1100 nm. Also, the dispersion was measured from 400 to 700 nm for aqueous and vitreous humor extracted from goat and rhesus monkey eyes. For the humors, the dispersion did not deviate significantly from water. In an additional experiment, the dispersion of aqueous and vitreous humor that had aged up to a month was compared to freshly harvested material. No difference was found between the fresh and aged media. An unsuccessful attempt was also made to use the technique for dispersion measurement of bovine cornea and lens. Future refinement may allow measurement of the dispersion of cornea and lens across the entire visible and near-infrared wavelength band. The principles of white- light interferometry including image analysis, measurement accuracy, and limitations of the technique, are discussed. In addition, alternate techniques and previous measurements of ocular dispersion are reviewed.
Current Perspectives of Prophylaxis and Management of Acute Infective Endophthalmitis.
Tranos, Paris; Dervenis, Nikolaos; Vakalis, Athanasios N; Asteriadis, Solon; Stavrakas, Panagiotis; Konstas, Anastasios G P
2016-05-01
Endophthalmitis is an intraocular inflammatory condition which may or may not be caused by infective agents. Noninfectious (sterile) endophthalmitis may be attributable to various causes including postoperative retained soft lens matter or toxicity following introduction of other agents into the eye. Infectious endophthalmitis is further subdivided into endogenous and exogenous. In endogenous endophthalmitis there is hematogenous spread of organisms from a distant source of infection whereas in exogenous endophthalmitis direct microbial inoculation may occur usually following ocular surgery or penetrating eye injury with or without intraocular foreign bodies. Acute infective endophthalmitis is usually exogenous induced by inoculation of pathogens following ocular surgery, open-globe injury and intravitreal injections. More infrequently the infective source is internal and septicemia spreads to the eye resulting in endogenous endophthalmitis. Several risk factors have been implicated including immunosuppression, ocular surface abnormalities, poor surgical wound construction, complicated cataract surgery with vitreous loss and certain types of intraocular lens. Comprehensive guidelines and recommendations on prophylaxis and monitoring of surgical cases have been proposed to minimize the risk of acute endophthalmitis. Early diagnosis and prompt management of infective endophthalmitis employing appropriately selected intravitreal antibiotics are essential to optimize visual outcome.
Al-Mezaine, Hani S
2010-01-01
We report a 55-year-old man with unusually dense, unilateral central posterior capsule pigmentation associated with the characteristic clinical features of pigment dispersion syndrome, including a Krukenberg's spindle and dense trabecular pigmentation in both eyes. A history of an old blunt ocular trauma probably caused separation of the anterior hyaloid from the back of the lens, thereby creating an avenue by which pigment could reach the potential space of Berger's from the posterior chamber.
NASA Astrophysics Data System (ADS)
Zuclich, Joseph A.
1980-10-01
Ocular effects of ultraviolet radiation, 200-400 nm, are reviewed. Depending upon the exposure parameter involved, UV radiation may be harmful to the cornea, lens and/or retina. Ranges of exposure parameters (wavelength, exposure duration, etc.) for which each of the tissues is susceptible are specified and the nature of the tissue is described. Present understanding of the thermal and photochemical damage mechanism operative for various conditions of exposure are discussed Ocular damage thresholds for wide ranges of exposure parameters are summarized and compared to existing safety standards.
Al-Mezaine, Hani S
2010-01-01
We report a 55-year-old man with unusually dense, unilateral central posterior capsule pigmentation associated with the characteristic clinical features of pigment dispersion syndrome, including a Krukenberg's spindle and dense trabecular pigmentation in both eyes. A history of an old blunt ocular trauma probably caused separation of the anterior hyaloid from the back of the lens, thereby creating an avenue by which pigment could reach the potential space of Berger's from the posterior chamber. PMID:20534930
Guillon, Michel; Maissa, Cecile; Pouliquen, Pascale; Delval, Laurent
2004-01-01
To show that the use of povidone 2% preservative-free lubricating eyedrops reduces computer visual syndrome in contact lens wearers and to identify the best eyedrop instillation protocols. The test product was FILMABAK a CE-marked nonpreserved lubricant, povidone 2% delivered by the ABAK system. Three dispensing modalities were evaluated during contact lens wear and computer use: hourly instillation, symptom-related instillation, and patient's own instillation. During sustained computer use, a decrease in symptoms associated with the use of povidone 2% was statistically and clinically significant. However, the symptoms were not fully eliminated by the use of the test eyedrop. The three instillation routines achieved similar beneficial effects. No significant changes in ocular tissue response were observed, and the staining recorded after sustained computer use remained low. The use of povidone 2% preservative-free lubricating eyedrops under any of the three instillation modalities tested was also associated with a slight improvement in dynamic visual acuity. The use of povidone 2% preservative-free eyedrops was associated with an improvement in symptoms during sustained computer use. Any of the three instillation modalities decreased symptoms of ocular tiredness, dryness, and difficulty of focus; maintained an unchanged corneal surface; and improved dynamic visual acuity. Therefore, the most patient-friendly modality (patient's own instillation modality from symptom onset) could be recommended to contact lens wearers with computer visual syndrome.
Reddy, Paduru Yadagiri; Giridharan, Nappan Veettil; Balakrishna, Nagalla; Validandi, Vakdevi; Pullakhandam, Raghu; Reddy, Geereddy Bhanuprakash
2013-05-01
Epidemiological studies have reported an association between obesity and increased incidence of ocular complications including cataract, yet the underlying biochemical and molecular mechanisms remained unclear. Previously we had demonstrated accumulation of sorbitol in the lens of obese rats (WNIN/Ob) and more so in a related strain with impaired glucose tolerance (WNIN/GR-Ob). However, only a few (15-20%) WNIN/Ob and WNIN/GR-Ob rats develop cataracts spontaneously with age. To gain further insights, we investigated the susceptibility of eye lens proteins of these obese rat strains to heat- and UV-induced aggregation in vitro, lens opacification upon glucose-mediated sorbitol accumulation ex vivo, and onset and progression of cataract was followed by galactose feeding and streptozotocin (STZ) injection. The results indicated increased susceptibility toward heat- or UV-induced aggregation of lens proteins in obese animals compared to their littermate lean controls. Further, in organ culture studies glucose-induced sorbitol accumulation was found to be higher and thus the lens opacification was faster in obese animals compared to their lean littermates. Also, the onset and progression of galactose- or STZ-induced cataractogenesis was faster in obese animals compared to lean control. These results together with our previous observations suggest that obesity status could lead to hyperaccumulation of sorbitol in eye lens, predisposing them to cataract, primarily by increasing their susceptibility to environmental and/or physiological factors. Further, intralenticular sorbitol accumulation beyond a threshold level could lead to cataract in WNIN/Ob and WNIN/GR-Ob rats. Copyright © 2013 International Union of Biochemistry and Molecular Biology, Inc.
2007-07-01
retina . Our experiments have so far been limited to sheep. Our experiments have been designed to address the following questions: 1. Can ocular spectra...components and reports that the cornea, lens, retina , and optic nerve show promise. Of these, the optic nerve showed the most potential for changes in...investigations so far suggest that the most promising part of the eye for revealing spectroscopic signatures of neurological disease is the retina . Our
Characteristics of Anterior Lens Opacities in Children
Dixit, Lena; Puente, Michael; Yen, Kimberly G.
2017-01-01
Background: Anterior lens opacities (ALO) are found in 3-14% of pediatric patients with cataracts. No clear guidelines exist in the management and treatment of these cataracts. Objective: To evaluate pediatric patients with anterior lens opacities and assess rate of amblyopia and need for surgery over time. Methods: A retrospective chart review was performed on patients with unilateral and bilateral anterior lens opacities (ALOs) seen between January 2008 and December 2014. Size, location, and type of ALO were noted. Refractive error, necessity for treatment of amblyopia, and interventions were recorded. Results: A total of 31 patients were included in the study. 17 patients had unilateral ALOs and 14 had bilateral ALOs. The majority of the cataracts (90.3%) were centrally located. The most common type of cataract was the polar type of cataract and the vast majority (48.4%) was < 1mm in size. 38.7% of patients had concurrent ocular conditions and 9.7% had systemic associations. 28.6% of patients with bilateral cataracts and 35.3% of the patients with unilateral cataracts were treated for amblyopia. Three patients required cataract surgery. Conclusion: About half of anterior lens opacities are less than 1mm in size and the majority are of the polar type. Risk of amblyopia in these patients is higher than in the general population. Anisometropia is the most common cause of amblyopia. Ocular associations are seen at a relatively high frequency and systemic associations can occur but are uncommon. The need for surgical intervention is infrequent; however, growth of ALOs and associated cortical changes may be risk factors for surgery. PMID:28553426
Ocular biometric measurements in cataract surgery candidates in Portugal.
Ferreira, Tiago B; Hoffer, Kenneth J; Ribeiro, Filomena; Ribeiro, Paulo; O'Neill, João G
2017-01-01
Describe the ocular biometric parameters and their associations in a population of cataract surgery candidates. A cross-sectional study of 13,012 eyes of 6,506 patients was performed. Biometric parameters of the eyes were measured by optical low-coherence reflectometry. The axial length (AL), mean keratometry (K) and astigmatism, anterior chamber depth (ACD) (epithelium to lens), lens thickness (LT), and Corneal Diameter (CD) were evaluated. The mean age was 69 ± 10 years (44-99 years). Mean AL, Km, and ACD were 23.87 ± 1.55 mm (19.8-31.92 mm), 43.91 ± 1.71 D (40.61-51.14 D), and 3.25 ± 0.44 mm (2.04-5.28 mm), respectively. The mean LT was 4.32 ± 0.49 mm (2.73-5.77 mm) and the mean CD was 12.02 ± 0.46 mm (10.50-14.15 mm). The mean corneal astigmatism was 1.08 ± 0.84 D (0.00-7.58 D) and 43.5% of eyes had astigmatism ≥ 1.00 D. Male patients had longer AL and ACDs (p < .001) and flatter corneas (p < .001). In regression models considering age, gender, Km, ACD, LT, and CD, a longer AL was associated with being male and having higher ACD, LT and CD. These data represent normative biometric values for the Portuguese population. The greatest predictor of ocular biometrics was gender. There was no significant correlation between age and AL, ACD, or Km. These results may be relevant in the evaluation of refractive error and in the calculation of intraocular lens power.
Electrically atomised formulations of timolol maleate for direct and on-demand ocular lens coatings.
Mehta, Prina; Al-Kinani, Ali A; Haj-Ahmad, Rita; Arshad, Muhammad Sohail; Chang, Ming-Wei; Alany, Raid G; Ahmad, Zeeshan
2017-10-01
Advances in nanotechnology have enabled solutions for challenging drug delivery targets. While the eye presents numerous emerging opportunities for delivery, analysis and sensing; issues persist for conventional applications. This includes liquid phase formulation localisation on the ocular surface once administered as formulated eye-drops; with the vast majority of dosage (>90%) escaping from the administered site due to tear production and various drainage mechanisms. The work presented here demonstrates a single needle electrohydrodynamic (EHD) engineering process to nano-coat (as an on demand and controllable fiber depositing method) the surface of multiple contact lenses rendering formulations to be stationary on the lens and at the bio-interface. The coating process was operational based on ejected droplet charge and glaucoma drug timolol maleate (TM) was used to demonstrate surface coating optimisation, bio-surface permeation properties (flux, using a bovine model) and various kinetic models thereafter. Polymers PVP, PNIPAM and PVP:PNIPAM (50:50%w/w) were used to encapsulate the active. Nano-fibrous and particulate samples were characterised using SEM, FTIR, DSC and TGA to confirm structural and thermal stability of surface coated formulations. More than 52% of nano-structured coatings (for all formulations) were <200nm in diameter. In vitro studies show coatings to exhibit biphasic release profiles; an initial burst release followed by sustained release; with TM-loaded PNIPAM coating releasing most drug after 24h (89.8%). Kinetic modelling (Higuchi, Korsmeyer-Peppas) was indicative of quasi-Fickian diffusion whilst biological evaluation demonstrates adequate ocular tolerability. Results from permeation studies indicate coated lenses are ideal to reduce dosing regimen, which in turn will reduce systemic drug absorption. Florescent microscopy demonstrated probe and probe embedded coating behaviour from lens surface in vitro. The multiple lens surface coating method demonstrates sustained drug release yielding promising results; suggesting both novel device and method to enhance drug activity at the eyes surface which will reduce formulation drainage. Crown Copyright © 2017. Published by Elsevier B.V. All rights reserved.
Brooks, Brian P; Thompson, Amy H; Bishop, Rachel J; Clayton, Janine A; Chan, Chi-Chao; Tsilou, Ekaterini T; Zein, Wadih M; Tamura, Deborah; Khan, Sikandar G.; Ueda, Takahiro; Boyle, Jennifer; Oh, Kyu-Seon; Imoto, Kyoko; Inui, Hiroki; Moriwaki, Shin-Ichi; Emmert, Steffen; Iliff, Nicholas T.; Bradford, Porcia; DiGiovanna, John J.; Kraemer, Kenneth H
2013-01-01
Objective Xeroderma pigmentosum (XP) is a rare autosomal recessive disease caused by mutations in DNA repair genes. Clinical manifestations of XP include mild to extreme sensitivity to ultraviolet radiation resulting in inflammation and neoplasia in sun-exposed areas of the skin, mucous membranes, and ocular surfaces. This report describes the ocular manifestations of XP in patients systematically evaluated in the Clinical Center at the National Institutes of Health. Design Retrospective Observational Case Series Participants Eighty-seven participants, aged 1.3 to 63.4 years, referred to the National Eye Institute for examination from 1964 to 2011. Eighty-three had XP, 3 had XP/Cockayne Syndrome complex, and 1 had XP/trichothiodystrophy complex. Methods Complete, age- and developmental stage-appropriate ophthalmic examination. Main Outcome Measures Visual acuity; eyelid, ocular surface and lens pathology; tear film and tear production measures; and cytological analysis of conjunctival surface swabs. Results Of the 87 patients, 91% had at least one ocular abnormality. The most common abnormalities were conjunctivitis (51%), corneal neovascularization (44%), dry eye (38%), corneal scarring (26%), ectropion (25%), blepharitis (23%), conjunctival melanosis (20%), and cataracts (14%). Thirteen percent of patients had some degree of visual axis impingement and 5% had no light perception in one or both eyes. Ocular surface cancer or a history of ocular surface cancer was present in 10% of patients. Patients with an acute sunburning skin phenotype were less likely to develop conjunctival melanosis and ectropion but more likely to develop neoplastic ocular surface lesions than non-burning patients. Some patients also showed signs of limbal stem cell deficiency. Conclusions Our longitudinal study reports the ocular status of the largest group of XP patients systematically examined at one facility over an extended period of time. Structural eyelid abnormalities, neoplasms of the ocular surface and eyelids, tear film and tear production abnormalities, ocular surface disease and inflammation, as well as corneal abnormalities were present in this population. Burning and non-burning XP patients exhibit different rates of important ophthalmologic findings, including neoplasia. Additionally, ophthalmic characteristics can help refine diagnoses in the case of XP complex phenotypes. DNA repair plays major role in protection of the eye from sunlight induced damage. PMID:23601806
Lehmann, David M; Cavet, Megan E; Richardson, Mary E
2010-12-01
Multipurpose solutions (MPS) often contain low concentrations of boric acid as a buffering agent. Limited published literature has suggested that boric acid and borate-buffered MPS may alter the corneal epithelium; an effect attributed to cytotoxicity induced by boric acid. However, this claim has not been substantiated. We investigated the effect of treating cells with relevant concentrations of boric acid using two cytotoxicity assays, and also assessed the impact of boric acid on corneal epithelial barrier function by measuring TEER and immunostaining for tight junction protein ZO-1 in human corneal epithelial cells. Boric acid was also assessed in an in vivo ocular model when administered for 28 days. Additionally, we evaluated Biotrue multi-purpose solution, a novel borate-buffered MPS, alone and with contact lenses for ocular compatibility in vitro and in vivo. Boric acid passed both cytotoxicity assays and did not alter ZO-1 distribution or corneal TEER. Furthermore, boric acid was well-tolerated on-eye following repeated administration in a rabbit model. Finally, Biotrue multi-purpose solution demonstrated good ocular biocompatibility both in vitro and in vivo. This MPS was not cytotoxic and was compatible with the eye when administered alone and when evaluated with contact lenses. We demonstrate that boric acid and a borate-buffered MPS is compatible with the ocular environment. Our findings provide evidence that ocular effects reported for some borate-buffered MPS may be incorrectly attributed to boric acid and are more likely a function of the unique combination of ingredients in the MPS formulation tested. Copyright © 2010 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
In Vivo Confocal Microscopy of the Ocular Surface: From Bench to Bedside
Villani, Edoardo; Baudouin, Christophe; Efron, Nathan; Hamrah, Pedram; Kojima, Takashi; Patel, Sanjay V.; Pflugfelder, Stephen C.; Zhivov, Andrey; Dogru, Murat
2014-01-01
In vivo confocal microscopy (IVCM) is an emerging technology that provides minimally invasive, high resolution, steady-state assessment of the ocular surface at the cellular level. Several challenges still remain but, at present, IVCM may be considered a promising technique for clinical diagnosis and management. This mini-review summarizes some key findings in IVCM of the ocular surface, focusing on recent and promising attempts to move “from bench to bedside”. IVCM allows prompt diagnosis, disease course follow-up, and management of potentially blinding atypical forms of infectious processes, such as acanthamoeba and fungal keratitis. This technology has improved our knowledge of corneal alterations and some of the processes that affect the visual outcome after lamellar keratoplasty and excimer keratorefractive surgery. In dry eye disease, IVCM has provided new information on the whole-ocular surface morphofunctional unit. It has also improved understanding of pathophysiologic mechanisms and helped in the assessment of prognosis and treatment. IVCM is particularly useful in the study of corneal nerves, enabling description of the morphology, density, and disease- or surgically induced alterations of nerves, particularly the subbasal nerve plexus. In glaucoma, IVCM constitutes an important aid to evaluate filtering blebs, to better understand the conjunctival wound healing process, and to assess corneal changes induced by topical antiglaucoma medications and their preservatives. IVCM has significantly enhanced our understanding of the ocular response to contact lens wear. It has provided new perspectives at a cellular level on a wide range of contact lens complications, revealing findings that were not previously possible to image in the living human eye. The final section of this mini-review provides a focus on advances in confocal microscopy imaging. These include 2D wide-field mapping, 3D reconstruction of the cornea and automated image analysis. PMID:24215436
Kane, Frances E.
2015-01-01
Abstract Purpose: The purpose of this study was to evaluate the systemic and ocular pharmacokinetics (PK) of fluocinolone acetonide (FAc) following administration of Iluvien® intravitreal implants. Methods: The FAc intravitreal implant was administered to rabbits in 3 doses (0.2, 0.5, and 1.0 μg/day). The concentration of FAc was measured by a validated liquid chromatography-mass spectrometry/mass spectrometry (LC-MS/MS) method in plasma and ocular tissues at various time points through month 24. Results: Following administration of the 0.2 μg/day implant, FAc levels peaked in most tissues at day 2 or 8, reached approximate steady state levels by month 3 and very gradually decreased over the duration of the study. The FAc level in the aqueous humor was not measurable at most time points in the rabbit. FAc was still present in most ocular tissues at 2 years. The 0.5 and 1.0 μg/day dose groups followed the same pattern through month 9. The elimination half lives in the tissues for which it was measurable were greater than 83 days. Exposure to FAc was highest in the choroid/retinal pigment epithelium for all doses, followed by lens and retina. Conclusions: The results of this study demonstrate sustained delivery of FAc from the Iluvien intravitreal implant in the ocular tissue of rabbits. Retina and lens FAc levels with the Iluvien implant were approximately 1/10 those reported with the Retisert® implant. FAc levels in the aqueous were not measureable with Iluvien where they were measured for 12 months with Retisert. PMID:25562126
The RNA-binding protein Musashi-1 is produced in the developing and adult mouse eye.
Raji, B; Dansault, A; Leemput, J; de la Houssaye, G; Vieira, V; Kobetz, A; Arbogast, L; Masson, C; Menasche, M; Abitbol, M
2007-08-10
Musashi-1 (Msi1) is an RNA-binding protein produced in various types of stem cells including neural stem/progenitor cells and astroglial progenitor cells in the vertebrate central nervous system. Other RNA-binding proteins such as Pumilio-1, Pumilio-2, Staufen-1, and Staufen-2 have been characterized as potential markers of several types of stem or progenitor cells. We investigated the involvement of Msi1 in mouse eye development and adult mouse eye functions by analyzing the profile of Msi1 production in all ocular structures during development and adulthood. We studied Msi1 production by in situ hybridization and immunohistochemistry of ocular tissue sections and by semi-quantitative RT-PCR and western blot analysis from the embryonic stage of 12.5 days post coitum (E12.5 dpc) when the first retinal ganglion cells (RGCs) begin to appear to the adult stage when all retinal cell types are present. Msi1 mRNA was present at all studied stages of eye development. Msi1 protein was detected in the primitive neuroblastic layer (NbL), the ganglion cell layer (GCL), and in all major differentiated neurons of postnatal developing and adult retinae. During postnatal developing stages, faint diffuse Msi1 protein staining is converted to a more specific distribution once mouse retina is fully differentiated. The most striking result of our study concerns the large amounts of Msi1 protein and mRNA in several unexpected sites of adult mouse eyes including the corneal epithelium and endothelium, stromal keratocytes, progenitor cells of the limbus, equatorial lens stem cells, differentiated lens epithelial cells, and differentiating lens fibers. Msi1 was also found in the pigmented and nonpigmented cells of the ciliary processes, the melanocytes of the ciliary body, the retinal pigment epithelium, differentiated retinal neurons, and most probably in the retinal glial cells such as Müller glial cells, astrocytes, and the oligodendocytes surrounding the axons of the optic nerve. Msi1 expression was detected in the outer plexiform layer, the inner plexiform layer, and the nerve fiber layer of fully differentiated adult retina. We provide here the first demonstration that the RNA-binding protein, Msi1, is produced in mouse eyes from embryonic stages until adulthood. The relationship between the presence of Msi1 in developing ocular compartments and the possible stem/progenitor cell characteristics of these compartments remains unclear. Finally, the expression of Msi1 in several different cell types in the adult eye is extremely intriguing and should lead to further attempts to unravel the role of Msi1 in cellular and subcellular RNA metabolism and in the control of translational processes in adult eye cells particularly in adult neuronal dendrites, axons, and synapses.
Babizhayev, Mark A
2012-08-01
Cataract is a leading cause of blindness worldwide and is responsible for ∼40-80% of the estimated 45 million cases of blindness that occur across the globe. In addition to providing refractive properties to the lens for focusing the image, it is believed that the molecular chaperone function of α-crystallin is essential in preventing the light scattering due to aggregation of other proteins and thus in the maintenance of lens transparency and thereby prevention of cataract. By now, it is fairly acknowledged that chaperoning ability of α-crystallin is instrumental in the maintenance of crystalline lens transparency, and decreased chaperone-like activity of α-crystallin is associated with various types and stages of cataract. A better pharmacological targeting of safeguarding the α-crystallin chaperone activity may aid the development of therapeutic strategies that could evade the need for cataract surgery and revive lens transparency of the cataractous lenses. This article originally summarizes the significance of modulation and enhancing of α-crystallin chaperone activity with imidazole-containing dipeptides N-acetylcarnosine, carnosine and carcinine in consequence to prevent, delay or dissolve the human cataract. A growing evidence and discussion of recent patents are presented in this study that demonstrate the ability of N-acetylcarnosine (lubricant eye drops) or carcinine (lubricant eye drops) (universal antioxidant and deglycation agent) resistant to enzymatic hydrolysis with carnosinase to act as pharmacological chaperones, to decrease oxidative stress and ameliorate oxidative and excessive glycation stress-related eye disease phenotypes, suggesting that the field of chaperone therapy might hold novel treatments for age-related cataracts, age-related macular degeneration (AMD) and ocular complications of diabetes (OCD). The therapeutic strategies are highlighted in the study for identifying potential chaperone compounds and for experimentally demonstrating chaperone activity in in vitro and in vivo models of human age-related eye disease, such as cataracts and advanced glycation tissue proteins - engineered systems.
François Pourfour du Petit (1664-1741): pioneer in ocular biometry.
Charman, W Neil
2016-07-01
To outline the important contributions of the French physician Petit to the development of ocular biometry. After a brief review of Petit's life and his studies in neurology, anatomy, and cataract surgery, the methodology and results of his work in measuring many of the biometric parameters of the human eye are discussed. Among other techniques, he made use of frozen sections of eyes to explore their dimensions and employed an immersion technique to avoid the effect of corneal refraction on the appearance of the iris. His pioneering biometric results have been largely confirmed by modern studies. Those on the changes in the crystalline lens with age are particularly striking and suggest that these ocular aging effects have changed little over the last 300 years. Although largely forgotten today, his biometric work exercised a considerable influence on his more immediate successors, including Porterfield and Thomas Young. François Pourfour du Petit deserves to be remembered as an important contributor to our understanding of the structure and dimensions of the human eye. © 2016 The Authors Ophthalmic & Physiological Optics © 2016 The College of Optometrists.
Egr1 gene knockdown affects embryonic ocular development in zebrafish.
Hu, Chao-Yu; Yang, Chang-Hao; Chen, Wei-Yu; Huang, Chiu-Ju; Huang, Hsing-Yen; Chen, Muh-Shy; Tsai, Huai-Jen
2006-10-26
To identify the changes in zebrafish embryonic ocular development after early growth response factor 1 (Egr1) gene knockdown by Egr1-specific translation inhibitor, morpholino oligonucleotides (MO). Two kinds of Egr1-MO were microinjected separately with various dosages into one to four celled zebrafish embryos to find an optimal dose generating an acceptable mortality rate and high frequency of specific phenotype. Chordin-MO served as the positive control; a 5 mismatch MO of Egr1-MO1 and a nonspecific MO served as negative controls. We graded the Egr1 morphants according to their gross abnormalities, and measured their ocular dimensions accordingly. Western blot analysis and synthetic Egr1 mRNA rescue experiments confirmed whether the deformities were caused by Egr1 gene knockdown. Histological examination and three kinds of immunohistochemical staining were applied to identify glutamate receptor one expression in retinal ganglion cells and amacrine cells, to recognize acetylated alpha-tubulin expression which indicated axonogenesis, and to label photoreceptor cells with zpr-1 antibody. After microinjection of 8 ng Egr1-MO1 or 2 ng Egr1-MO2, 81.8% and 97.3% of larvae at 72 h postfertilization had specific defects, respectively. The gross phenotype included string-like heart, flat head, and deformed tail. The more severely deformed larvae had smaller eyes and pupils. Co-injection of 8 ng Egr1-MO1 and supplementary 12 pg synthetic Egr1 mRNA reduced the gross abnormality rate from 84.4% to 29.7%, and decreased the severity of deformities. Egr1 protein appeared in the wildtype and rescued morphants, but was lacking in the Egr1 morphants with specific deformities. Lenses of Egr1 morphants were smaller and had some residual nucleated lens fiber cells. Morphants' retinal cells arranged disorderly and compactly with thin plexiform layers. Immunohistochemical studies showed that morphants had a markedly decreased number of mature retinal ganglion cells, amacrine cells, and photoreceptor cells. Retinal axonogenesis was prominently reduced in morphants. The Egr1 gene plays an important role in zebrafish embryonic oculogenesis. Ocular structures including lens and retina were primitive and lacked appropriate differentiation. Such arrested retinal and lenticular development in Egr1 morphants resulted in microphthalmos.
Comfort, Ocular Dryness, and Equilibrium Water Content Changes of Daily Disposable Contact Lenses.
Insua Pereira, Eduardo; Lira, Madalena
2017-10-26
The objective of this investigation was to evaluate the level of comfort and ocular dryness during wear with six daily disposable contact lenses (DDCL) and also determine the changes in contact lens equilibrium water content (EWC) resulting from their wear. In this contralateral open trial, 27 subjects were randomly fitted with six DDCL (stenfilcon A, delefilcon A, nelfilcon A, narafilcon A, nesofilcon A, and omafilcon A). The evaluation of comfort and ocular dryness sensation was recorded by the participants at two moments of the day (11 AM and 5 PM) over a period of 10 days of contact lens wear. The assessment was made with the aid of visual analogue scales (0-10). The refractive index of 54 contact lenses was accessed by a single operator using a digital automated refractometer (CLR 12-70; Index Instruments). The EWC of the lenses was estimated based on its refractive index values. Comfort ratings were slightly higher for delefilcon A (9.56±0.67, P=0.01) and narafilcon A (9.40±0.93, P=0.01) and these lenses wearers also reported less ocular dryness. The results revealed a pronounced water content reduction for omafilcon A (P=0.002), narafilcon A (P=0.008), and nesofilcon A (P=0.003). Although changes in subjective responses and EWC were distinct among the materials analyzed, all the contact lenses performed well during the 10 days of wear.
Ho, Kam Chun; Jalbert, Isabelle; Watt, Kathleen; Golebiowski, Blanka
2017-07-01
To examine the relationship between dry eye symptoms and adiposity in a population study. A prospective cross-sectional single-visit preliminary study was designed to sample ocular symptoms and indices of adiposity in the general adult population. Patients recruited from the UNSW optometry clinic, the university campus and surrounding community, and overseas were invited to complete a survey composed of the short form Dry Eye Questionnaire (SFDEQ) (Dry Eye Questionnaire-5 or Contact Lens Dry Eye Questionnaire-8) and the Ocular Comfort Index (OCI) via hardcopy or online. Participants self-measured their weight, height, waist circumference (WC), and body fat % (optional). Associations between measures of adiposity (Body mass index [BMI], WC, and body fat %) and ocular symptoms scores (SFDEQ and OCI) were determined using Spearman correlation coefficients. Group differences were compared using independent t test. Three hundred and five participants including 52 contact lens wearers completed the study and 78 of them measured body fat %. There was a moderate correlation between body fat % and dry eye symptoms (SFDEQ r=0.34, P=0.003; OCI r=0.32, P=0.004). The interaction between body fat % and gender, wear of contact lenses, and older age were shown to be significant predictors of less ocular comfort in multivariate analysis (F(3,74)=12.13, P<0.001). An association between adiposity measured by body fat % and symptoms of dry eye was demonstrated in the general adult population. Confirmation of these findings in a large study is required.
Mechanical properties of intra-ocular lenses
NASA Astrophysics Data System (ADS)
Ehrmann, Klaus; Kim, Eon; Parel, Jean-Marie
2008-02-01
Cataract surgery usually involves the replacement of the natural crystalline lens with a rigid or foldable intraocular lens to restore clear vision for the patient. While great efforts have been placed on optimising the shape and optical characteristics of IOLs, little is know about the mechanical properties of these devices and how they interact with the capsular bag once implanted. Mechanical properties measurements were performed on 8 of the most commonly implanted IOLs using a custom build micro tensometer. Measurement data will be presented for the stiffness of the haptic elements, the buckling resistance of foldable IOLs, the dynamic behaviour of the different lens materials and the axial compressibility. The biggest difference between the lens types was found between one-piece and 3-piece lenses with respect to the flexibility of the haptic elements
Sun, Ning; Shibata, Brad; Hess, John F.
2015-01-01
Purpose Several properties of ocular tissue make fixation for light microscopy problematic. Because the eye is spherical, immersion fixation necessarily results in a temporal gradient of fixation, with surfaces fixing more rapidly and thoroughly than interior structures. The problem is compounded by the fact that the layers of the eye wall are compositionally quite different, resulting in different degrees of fixation-induced shrinkage and distortion. Collectively, these result in non-uniform preservation, as well as buckling and/or retinal detachment. This gradient problem is most acute for the lens, where the density of proteins can delay fixation of the central lens for days, and where the fixation gradient parallels the age gradient of lens cells, which complicates data interpretation. Our goal was to identify a simple method for minimizing some of the problems arising from immersion fixation, which avoided covalent modification of antigens, retained high quality structure, and maintained tissue in a state that is amenable to common cytochemical techniques. Methods A simple and inexpensive derivative of the freeze-substitution approach was developed and compared to fixation by immersion in formalin. Preservation of structure, immunoreactivity, GFP and tdTomato fluorescence, lectin reactivity, outer segment auto fluorescence, Click-iT chemistry, compatibility with in situ hybdrdization, and the ability to rehydrate eyes after fixation by freeze substitution for subsequent cryo sectioning were assessed. Results An inexpensive and simple variant of the freeze substitution approach provides excellent structural preservation for light microscopy, and essentially eliminates ocular buckling, retinal detachment, and outer segment auto-fluorescence, without covalent modification of tissue antigens. The approach shows a notable improvement in preservation of immunoreactivity. TdTomato intrinsic fluorescence is also preserved, as is compatibility with in situ hybridization, lectin labeling, and the Click-iT chemistry approach to labeling the thymidine analog EdU. On the negative side, this approach dramatically reduced intrinsic GFP fluorescence. Conclusions A simple, cost-effective derivative of the freeze substitution process is described that is of particular value in the study of rodent or other small eyes, where fixation gradients, globe buckling, retinal detachment, differential shrinkage, autofluorescence, and tissue immunoreactivity have been problematic. PMID:25991907
DOT National Transportation Integrated Search
1977-03-01
Visual acuity was determined at the intermediate range for older individuals with various combinations of ocular refractive error (nine subcategories) and accommodative power (three subcategories). Subjects (N=249) read numerals ranging in size to me...
Method for quantifying optical properties of the human lens
Loree, deceased, Thomas R.; Bigio, Irving J.; Zuclich, Joseph A.; Shimada, Tsutomu; Strobl, Karlheinz
1999-01-01
Method for quantifying optical properties of the human lens. The present invention includes the application of fiberoptic, OMA-based instrumentation as an in vivo diagnostic tool for the human ocular lens. Rapid, noninvasive and comprehensive assessment of the optical characteristics of a lens using very modest levels of exciting light are described. Typically, the backscatter and fluorescence spectra (from about 300- to 900-nm) elicited by each of several exciting wavelengths (from about 300- to 600-nm) are collected within a few seconds. The resulting optical signature of individual lenses is then used to assess the overall optical quality of the lens by comparing the results with a database of similar measurements obtained from a reference set of normal human lenses having various ages. Several metrics have been identified which gauge the optical quality of a given lens relative to the norm for the subject's chronological age. These metrics may also serve to document accelerated optical aging and/or as early indicators of cataract or other disease processes.
Method for quantifying optical properties of the human lens
Loree, T.R.; Bigio, I.J.; Zuclich, J.A.; Shimada, Tsutomu; Strobl, K.
1999-04-13
A method is disclosed for quantifying optical properties of the human lens. The present invention includes the application of fiberoptic, OMA-based instrumentation as an in vivo diagnostic tool for the human ocular lens. Rapid, noninvasive and comprehensive assessment of the optical characteristics of a lens using very modest levels of exciting light are described. Typically, the backscatter and fluorescence spectra (from about 300- to 900-nm) elicited by each of several exciting wavelengths (from about 300- to 600-nm) are collected within a few seconds. The resulting optical signature of individual lenses is then used to assess the overall optical quality of the lens by comparing the results with a database of similar measurements obtained from a reference set of normal human lenses having various ages. Several metrics have been identified which gauge the optical quality of a given lens relative to the norm for the subject`s chronological age. These metrics may also serve to document accelerated optical aging and/or as early indicators of cataract or other disease processes. 8 figs.
Age-dependence of the average and equivalent refractive indices of the crystalline lens
Charman, W. Neil; Atchison, David A.
2013-01-01
Lens average and equivalent refractive indices are required for purposes such as lens thickness estimation and optical modeling. We modeled the refractive index gradient as a power function of the normalized distance from lens center. Average index along the lens axis was estimated by integration. Equivalent index was estimated by raytracing through a model eye to establish ocular refraction, and then backward raytracing to determine the constant refractive index yielding the same refraction. Assuming center and edge indices remained constant with age, at 1.415 and 1.37 respectively, average axial refractive index increased (1.408 to 1.411) and equivalent index decreased (1.425 to 1.420) with age increase from 20 to 70 years. These values agree well with experimental estimates based on different techniques, although the latter show considerable scatter. The simple model of index gradient gives reasonable estimates of average and equivalent lens indices, although refinements in modeling and measurements are required. PMID:24466474
Disinfection capacity of PuriLens contact lens cleaning unit against Acanthamoeba.
Hwang, Thomas S; Hyon, Joon Young; Song, Jae Kyung; Reviglio, Victor E; Spahr, Harry T; O'Brien, Terrence P
2004-01-01
The PuriLens contact lens system is indicated for cleaning and disinfection of soft (hydrophilic) contact lenses by means of subsonic agitation to remove lens deposits and microorganisms, and ultraviolet irradiation of the storage solution for disinfection. The capacity of the PuriLens system to disinfect storage solutions contaminated with known concentrations of Staphylococcus aureus, Pseudomonas aeruginosa, and Acanthamoeba species was evaluated. An in vitro assessment of the antibacterial and antiparasitic efficacy of the PuriLens system was performed. Separated batches of the storage solution for the cleansing system were contaminated with stock strains of S. aureus and P. aeruginosa. A comparison of the microbiologic content was made between the solution before and after the cycle. The PuriLens system effectively eradicated S. aureus and P. aeruginosa organisms after a 15-minute cycle. However, viable cysts of acanthamoeba were recovered in the solution after the 15-minute cycle. The PuriLens system is highly efficient in protecting against contamination with common bacterial ocular pathogens. Acanthamoeba cysts, however, can survive in the solution or contact lens bath undergoing integrated subsonic debridement and indirect ultraviolet light disinfection. Use of chemical disinfecting solutions that contain agents such as chlorhexidine or other cationic antiseptics may be advisable in conjunction with use of the PuriLens device, especially in high-risk settings.
Negrone, Mario; Di Lascio, Doriana
2016-01-01
The new recommended equivalent (publication n. 118 of International Commission on Radiological Protection) dose limit for occupational exposure of the lens of the eye is based on prevention of radiogenic cataracts, with the underlying assumption of a nominal threshold which has been adjusted from 2,5 Gy to 0.5 Gy for acute or protracted exposure. The study aim was to determine the prevalence of ocular lens opacity among healthcare workers (radiologic technologists, physicians, physician assistants) with respect to occupational exposures to ionizing radiations. Therefore, we conducted another retrospective study to explore the relationship between occupational exposure to radiation and opacity lens increase. Healthcare data (current occupational dosimetry, occupational history) are used to investigate risk of increase of opacity lens of eye. The sample of this study consisted of 148 health-workers (64 M and 84 W) aged from 28 to 66 years coming from different hospitals of the ASL of Potenza (clinic, hospital and institute with scientific feature). On the basis of the evaluation of the dosimetric history of the workers (global and effective dose) we agreed to ascribe the group of exposed subjects in cat A (equivalent dose > 2 mSV) and the group of non exposed subjects in cat B (workers with annual absorbed level of dose near 0 mSv). The analisys was conducted using SPSS 15.0 (Statistical Package for Social Science). A trend of increased ocular lens opacity was found with increasing number for workers in highest category of exposure (cat. A, Yates' chi-squared test = 13,7 p = 0,0002); variable significantly related to opacity lens results job: nurse (Χ(2)Y = 14,3 p = 0,0002) physician (Χ(2)Y = 2.2 p = 0,1360) and radiologic technologists (Χ(2)Y = 0,1 p = 0,6691). In conclusion our provides evidence that exposure to relatively low doses of ionizing radiation may be harmful to the lens of the eye and may increase a long-term risk of cataract formation; similary necessary to monitor the "equivalent dose" for the lens for the workers in highest category of exposure.
Gaiser, Hilary; Ho, Connie; Janier, Nicole; Wee, Amy; Johnson, Catherine; Watanabe, Ronald
2017-03-01
To describe practitioner experiences regarding ocular complications in patients wearing decorative contact lenses, and to investigate the compliance of unauthorized distributors of decorative contact lenses to current Food and Drug Administration (FDA) and Federal Trade Commission (FTC) regulations. Also, to provide data to support a more targeted public health approach to reducing the incidence of illegal contact lens sales and associated ocular complications. An institutional review board-approved online survey was distributed through mass email to a list of 98 optometrists in the Boston, MA area. Concurrently, an empirical evaluation of independent, online decorative contact lens sellers who were not associated with FDA-approved contact lens manufacturers was performed to determine their adherence to FDA and FTC guidelines. The first 18 noncoincidental websites that resulted from a Google search for "costume contact lens sellers" and "cosmetic contact lens sellers" were examined as to the brands and parameters of lenses being sold, whether or not a valid prescription was required or verified, and if consumer education was provided. Twenty-two optometrists completed the online survey. Seventy-seven percent of respondents reported having patients with complications from decorative contact lenses that were purchased both legally and illegally. The most common age group for complications was 18 to 25 years (61%). One third of complications were seen in first-time lens wearers, half of whom never received proper care instructions or were unaware that care instructions existed. One quarter of the lenses were purchased illegally with unlicensed stores being the most common place of purchase. Of the 18 online sites examined, 72% of sellers failed to adhere to FTC and FDA regulations. A significant number of individuals who obtain contact lenses illegally from unauthorized sources are young adults. Most unauthorized sellers reviewed did not adhere to the proper protocol for selling contact lenses or instruct their customers on proper lens wear and care. A significant percentage of optometrists responding to the survey reported complications associated with contact lenses purchased through unauthorized sources, suggesting that the risk of contact lens-related complications increases when the lenses are purchased from one of these sources.
Lin, Siying; Gupta, Bhaskar; Rossiter, Jonathan
2016-02-01
Minimally invasive glaucoma surgery is a developing area that has the potential to replace traditional glaucoma surgery, with its known risk profile, but at present there are no randomised controlled data to validate its use. We report on a case where sequential bilateral combined ab interno trabeculotomy and lens extraction surgery was performed on a 45-year-old woman with combined uveitic and chronic narrow angle raised intraocular pressure. Maximal medical management alone could not control the intraocular pressure. At 12-month follow-up, the patient had achieved stable intraocular pressure in both eyes on a combination of topical ocular antiglaucomatous and steroid therapies. This case demonstrates the effectiveness of trabecular meshwork ablation via ab interno trabeculotomy in a case of complex mixed mechanism glaucoma. 2016 BMJ Publishing Group Ltd.
Lin, Siying; Gupta, Bhaskar; Rossiter, Jonathan
2016-01-01
Minimally invasive glaucoma surgery is a developing area that has the potential to replace traditional glaucoma surgery, with its known risk profile, but at present there are no randomised controlled data to validate its use. We report on a case where sequential bilateral combined ab interno trabeculotomy and lens extraction surgery was performed on a 45-year-old woman with combined uveitic and chronic narrow angle raised intraocular pressure. Maximal medical management alone could not control the intraocular pressure. At 12-month follow-up, the patient had achieved stable intraocular pressure in both eyes on a combination of topical ocular antiglaucomatous and steroid therapies. This case demonstrates the effectiveness of trabecular meshwork ablation via ab interno trabeculotomy in a case of complex mixed mechanism glaucoma. PMID:26833953
Tognetto, Daniele; Pastore, Marco R; Cirigliano, Gabriella; DʼAloisio, Rossella; Borelli, Massimo; De Giacinto, Chiara
2017-11-16
To investigate long-term intraocular pressure trends after uncomplicated pars plana vitrectomy for idiopathic epiretinal membrane. Three hundred and sixty-eight eyes of 368 consecutive patients were enrolled. Changes in intraocular pressure 1, 3, 6, and 12 months after surgery and during the final follow-up visit were evaluated in vitrectomized eyes and nonvitrectomized fellow eyes. The median follow-up period was 36 months (range 12-92 months). Longitudinal data analysis evidenced a 2.5-mmHg (2.2 mmHg; 2.7 mmHg, 95% confidence interval) statistically significant difference in intraocular pressure 30 days after surgery between treated and fellow untreated eyes, gradually recovering to a not significant 0.2-mmHg (-0.1 mmHg; 0.4 mmHg, 95% confidence interval) difference within 26 months. The incidence of late-onset ocular hypertension was 5.7% (21 over 347, 2%; 12%, 95% confidence interval) without difference between the treated eyes and the group control. No significant difference in the incidence of late-onset ocular hypertension and sex, lens status, or gauge of vitrectomy instruments was detected. Only patient's age was significantly higher (mean difference 4.2 years; 0.1-8.0 years, Monte Carlo, 95% confidence interval) in those who developed late-onset ocular hypertension in the vitrectomized eye. Uncomplicated pars plana vitrectomy for idiopathic epiretinal membrane seems not to increase the risk of late-onset ocular hypertension or open-angle glaucoma development.
Ozdemir, Ozdemir; Tunay, Zuhal Ozen; Acar, Damla Erginturk; Erol, Muhammet Kazım; Sener, Ender; Acar, Ugur
2015-01-01
To analyze ocular biometry parameters and evaluate their relationship with gestational age, birth weight, and postmenstrual age in prematurely born infants. The right eyes of 361 premature infants born before the 36th gestational week were evaluated. Birth weight, gestational week, and gender were recorded. An A-scan Biometer was used for obtaining axial measurements, including anterior chamber depth, lens thickness, vitreous length, and total axial length. Gestational age and birth weight values ranged from 23 to 36 weeks and from 560 to 2,670 g, respectively. The mean gestational age and birth weight were 30.8 ± 2.8 weeks and 1,497.9 ± 483.6 g, respectively. During the first examination (4-5 weeks of postnatal age), birth weight and gestational age of the infants correlated significantly and positively with lens thickness, vitreous length, and axial length (r>0.5, p<0.001), but not with anterior chamber depth (r<0.5). Increased vitreous and axial lengths correlated significantly with increasing postmenstrual age of the infants (r=0.669, p<0.001; r=0.845, p<0.001, respectively). Lens thickness, vitreous length, and axial length, but not anterior chamber depth, were significantly correlated with birth weight and gestational age. All four parameters increased with increasing postmenstrual age, with higher correlations for vitreous and axial lengths than for anterior chamber depth and lens thickness. It was concluded that axial elongation resulted primarily from increasing posterior chamber length.
Sustained Ocular Delivery of Ciprofloxacin Using Nanospheres and Conventional Contact Lens Materials
Garhwal, Rahul; Shady, Sally F.; Ellis, Edward J.; Ellis, Jeanne Y.; Leahy, Charles D.; McCarthy, Stephen P.; Crawford, Kathryn S.
2012-01-01
Purpose. To formulate conventional contact lenses that incorporate nanosphere-encapsulated antibiotic and demonstrate that the lenses provide for sustained antibacterial activity. Methods. A copolymer composed of pullulan and polycaprolactone (PCL) was used to synthesize core-shell nanospheres that encapsulated ciprofloxacin. Bactericidal activity of the nanosphere-encapsulated ciprofloxacin (nanosphere/cipro) was tested by using liquid cultures of either Staphylococcus aureus or Pseudomonas aeruginosa. Nanosphere/cipro was then incorporated into HEMA-based contact lenses that were tested for growth inhibition of S. aureus or P. aeruginosa in liquid cultures inoculated daily with fresh bacteria. Lens designs included thin or thick lenses incorporating nanosphere/cipro and ciprofloxacin-HCl-soaked Acuvue lenses (Acuvue; Johnson & Johnson Vision Care, Inc., Jacksonville, FL). Results. Less than 2 μg/mL of nanosphere/cipro effectively inhibited the proliferation of cultures inoculated with 107 or 108 bacteria/mL of S. aureus and P. aeruginosa, respectively. HEMA-based contact lenses polymerized with nanosphere/cipro were transparent, effectively inhibited the proliferation of greater than 107/mL of bacteria added daily over 3 days of culture, and killed up to 5 × 109 total microbes in a single inoculation. A thicker lens design provided additional inhibition of bacterial growth for up to 96 hours. Conclusions. Core-shell nanospheres loaded with an antibiotic can be incorporated into a conventional, transparent contact lens and provide for sustained and effective bactericidal activity and thereby provide a new drug delivery platform for widespread use in treating ocular disorders. PMID:22266514
Ocular surface involvements in ectrodactyly-ectodermal dysplasia-cleft syndrome.
Kennedy, David P; Chandler, John W; McCulley, James P
2015-06-01
To present the ocular manifestation of 2 cases of ectrodactyly-ectodermal dysplasia-cleft syndrome, a multiple congenital anomaly syndrome caused by a single point mutation of the p63 gene that controls epidermal development and homeostasis and to present treatment options. Patient 1 presented with mild signs and symptoms of dry eye and limbal stem cell deficiency with retention of 20/30 vision. Patient 2 presented with severe signs and symptoms of limbal stem cell deficiency with diffuse corneal scarring and counting fingers vision. This second patient's course was complicated by allergic conjunctivitis and advanced steroid-induced glaucoma. The cause of visual loss in ectrodactyly-ectodermal dysplasia-cleft syndrome appears to be multifactorial and likely includes inflammation of the ocular surface, tear film abnormalities, eyelid abnormalities, and limbal stem cell deficiency. Treatment modalities including lubrication, contact lenses, and limbal stem cell transplantation are reviewed. The ophthalmic conditions seen in ectrodactyly-ectodermal dysplasia-cleft syndrome frequently lead to vision loss. Early correct diagnosis and appropriate therapy are paramount because p63 gene mutations have a critical role in maintaining the integrity of the ocular surface in the setting of limbal stem cell deficiency, especially if there are other ocular surface insults such as lid disease, meibomian gland dysfunction and toxicity from topical medications. Patients should be monitored at regular, frequent intervals; and particular attention should be taken to avoid adverse secondary effects of these conditions and medications. Copyright © 2015 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
Fukuda, Shinichi; Okuda, Kensuke; Kishino, Genichiro; Hoshi, Sujin; Kawano, Itsuki; Fukuda, Masahiro; Yamashita, Toshiharu; Beheregaray, Simone; Nagano, Masumi; Ohneda, Osamu; Nagasawa, Hideko; Oshika, Tetsuro
2016-12-01
Retinal hypoxia plays a crucial role in ocular neovascular diseases, such as diabetic retinopathy, retinopathy of prematurity, and retinal vascular occlusion. Fluorescein angiography is useful for identifying the hypoxia extent by detecting non-perfusion areas or neovascularization, but its ability to detect early stages of hypoxia is limited. Recently, in vivo fluorescent probes for detecting hypoxia have been developed; however, these have not been extensively applied in ophthalmology. We evaluated whether a novel donor-excited photo-induced electron transfer (d-PeT) system based on an activatable hypoxia-selective near-infrared fluorescent (NIRF) probe (GPU-327) responds to both mild and severe hypoxia in various ocular ischemic diseases animal models. The ocular fundus examination offers unique opportunities for direct observation of the retina through the transparent cornea and lens. After injection of GPU-327 in various ocular hypoxic diseases of mouse and rabbit models, NIRF imaging in the ocular fundus can be performed noninvasively and easily by using commercially available fundus cameras. To investigate the safety of GPU-327, electroretinograms were also recorded after GPU-327 and PBS injection. Fluorescence of GPU-327 increased under mild hypoxic conditions in vitro. GPU-327 also yielded excellent signal-to-noise ratio without washing out in vivo experiments. By using near-infrared region, GPU-327 enables imaging of deeper ischemia, such as choroidal circulation. Additionally, from an electroretinogram, GPU-327 did not cause neurotoxicity. GPU-327 identified hypoxic area both in vivo and in vitro.
Mertz, J R; Wallman, J
2000-04-01
Research over the past two decades has shown that the growth of young eyes is guided by vision. If near- or far-sightedness is artificially imposed by spectacle lenses, eyes of primates and chicks compensate by changing their rate of elongation, thereby growing back to the pre-lens optical condition. Little is known about what chemical signals might mediate between visual effects on the retina and alterations of eye growth. We present five findings that point to choroidal retinoic acid possibly being such a mediator. First, the chick choroid can convert retinol into all-trans-retinoic acid at the rate of 11 +/- 3 pmoles mg protein(-1) hr(-1), compared to 1.3 +/- 0.3 for retina/RPE and no conversion for sclera. Second, those visual conditions that cause increased rates of ocular elongation (diffusers or negative lens wear) produce a sharp decrease in all-trans-retinoic acid synthesis to levels barely detectable with our assay. In contrast, visual conditions which result in decreased rates of ocular elongation (recovery from diffusers or positive lens wear) produce a four- to five-fold increase in the formation of all-trans-retinoic acid. Third, the choroidal retinoic acid is found bound to a 28-32 kD protein. Fourth, a large fraction of the choroidal retinoic acid synthesized in culture is found in a nucleus-enriched fraction of sclera. Finally, application of retinoic acid to cultured sclera at physiological concentrations produced an inhibition of proteoglycan production (as assessed by measuring sulfate incorporation) with a EC50 of 8 x 10(-7) M. These results show that the synthesis of choroidal retinoic acid is modulated by those visual manipulations that influence ocular elongation and that this retinoic acid may reach the sclera in concentrations adequate to modulate scleral proteoglycan formation.
Ocular biometric measurements in cataract surgery candidates in Portugal
Hoffer, Kenneth J.; Ribeiro, Filomena; Ribeiro, Paulo; O’Neill, João G.
2017-01-01
Objective Describe the ocular biometric parameters and their associations in a population of cataract surgery candidates. Methods A cross-sectional study of 13,012 eyes of 6,506 patients was performed. Biometric parameters of the eyes were measured by optical low-coherence reflectometry. The axial length (AL), mean keratometry (K) and astigmatism, anterior chamber depth (ACD) (epithelium to lens), lens thickness (LT), and Corneal Diameter (CD) were evaluated. Results The mean age was 69 ± 10 years (44–99 years). Mean AL, Km, and ACD were 23.87 ± 1.55 mm (19.8–31.92 mm), 43.91 ± 1.71 D (40.61–51.14 D), and 3.25 ± 0.44 mm (2.04–5.28 mm), respectively. The mean LT was 4.32 ± 0.49 mm (2.73–5.77 mm) and the mean CD was 12.02 ± 0.46 mm (10.50–14.15 mm). The mean corneal astigmatism was 1.08 ± 0.84 D (0.00–7.58 D) and 43.5% of eyes had astigmatism ≥ 1.00 D. Male patients had longer AL and ACDs (p < .001) and flatter corneas (p < .001). In regression models considering age, gender, Km, ACD, LT, and CD, a longer AL was associated with being male and having higher ACD, LT and CD. Conclusions These data represent normative biometric values for the Portuguese population. The greatest predictor of ocular biometrics was gender. There was no significant correlation between age and AL, ACD, or Km. These results may be relevant in the evaluation of refractive error and in the calculation of intraocular lens power. PMID:28982150
Pentacam Scheimpflug quantitative imaging of the crystalline lens and intraocular lens.
Rosales, Patricia; Marcos, Susana
2009-05-01
To implement geometrical and optical distortion correction methods for anterior segment Scheimpflug images obtained with a commercially available system (Pentacam, Oculus Optikgeräte GmbH). Ray tracing algorithms were implemented to obtain corrected ocular surface geometry from the original images captured by the Pentacam's CCD camera. As details of the optical layout were not fully provided by the manufacturer, an iterative procedure (based on imaging of calibrated spheres) was developed to estimate the camera lens specifications. The correction procedure was tested on Scheimpflug images of a physical water cell model eye (with polymethylmethacrylate cornea and a commercial IOL of known dimensions) and of a normal human eye previously measured with a corrected optical and geometrical distortion Scheimpflug camera (Topcon SL-45 [Topcon Medical Systems Inc] from the Vrije University, Amsterdam, Holland). Uncorrected Scheimpflug images show flatter surfaces and thinner lenses than in reality. The application of geometrical and optical distortion correction algorithms improves the accuracy of the estimated anterior lens radii of curvature by 30% to 40% and of the estimated posterior lens by 50% to 100%. The average error in the retrieved radii was 0.37 and 0.46 mm for the anterior and posterior lens radii of curvature, respectively, and 0.048 mm for lens thickness. The Pentacam Scheimpflug system can be used to obtain quantitative information on the geometry of the crystalline lens, provided that geometrical and optical distortion correction algorithms are applied, within the accuracy of state-of-the art phakometry and biometry. The techniques could improve with exact knowledge of the technical specifications of the instrument, improved edge detection algorithms, consideration of aspheric and non-rotationally symmetrical surfaces, and introduction of a crystalline gradient index.
NASA Astrophysics Data System (ADS)
Wang, Kehao; Venetsanos, Demetrios; Wang, Jian; Pierscionek, Barbara K.
2016-08-01
The human lens provides one-third of the ocular focussing power and is responsible for altering focus over a range of distances. This ability, termed accommodation, defines the process by which the lens alters shape to increase or decrease ocular refractive power; this is mediated by the ciliary muscle through the zonule. This ability decreases with age such that around the sixth decade of life it is lost rendering the eye unable to focus on near objects. There are two opponent theories that provide an explanation for the mechanism of accommodation; definitive support for either of these requires investigation. This work aims to elucidate how material properties can affect accommodation using Finite Element models based on interferometric measurements of refractive index. Gradients of moduli are created in three models from representative lenses, aged 16, 35 and 48 years. Different forms of zonular attachments are studied to determine which may most closely mimic the physiological form by comparing stress and displacement fields with simulated shape changes to accommodation in living lenses. The results indicate that for models to mimic accommodation in living eyes, the anterior and posterior parts of the zonule need independent force directions. Choice of material properties affects which theory of accommodation is supported.
A noncontact pneumatic esthesiometer for measurement of ocular sensitivity: a preliminary report.
Vega, J A; Simpson, T L; Fonn, D
1999-11-01
The aim of this investigation was to evaluate a prototype noncontact pneumatic esthesiometer for measuring sensitivity of the eye. To evaluate the instrument's repeatability, central corneal sensitivity was recorded on two separate occasions with a 24-h interval between the two measures. In a separate experiment, corneal edema was induced with a thick hydrogel lens, and the eye was closed and patched. Corneal sensitivity was measured before wearing the lenses for 3 h, immediately after lens removal, and 15 min later. Corneal sensitivity also was measured before the instillation of a single drop of proparacaine (Alcaine, 0.5%) and at 2 and 18 min later. Sensitivity was measured at the corneal apex and at a temporal conjunctival location 3 mm from the limbus. A high correlation was found between days 1 and 2 (r = 0.90; p = 0.0001). The coefficient of repeatability (COR = 0.87 mm Hg) showed that 95% of the difference between test and retest measures were between +/-0.87 mm Hg. Corneal sensitivity decreased by 55% after lens-induced corneal swelling and by 159% after instillation of the topical anesthetic. Central corneal sensitivity was found to be significantly higher than that of the temporal conjunctiva (p = 0.0001). We conclude that this pneumatic esthesiometer provides repeatable and reliable measures of ocular-surface sensitivity.
Wang, Kehao; Venetsanos, Demetrios; Wang, Jian; Pierscionek, Barbara K.
2016-01-01
The human lens provides one-third of the ocular focussing power and is responsible for altering focus over a range of distances. This ability, termed accommodation, defines the process by which the lens alters shape to increase or decrease ocular refractive power; this is mediated by the ciliary muscle through the zonule. This ability decreases with age such that around the sixth decade of life it is lost rendering the eye unable to focus on near objects. There are two opponent theories that provide an explanation for the mechanism of accommodation; definitive support for either of these requires investigation. This work aims to elucidate how material properties can affect accommodation using Finite Element models based on interferometric measurements of refractive index. Gradients of moduli are created in three models from representative lenses, aged 16, 35 and 48 years. Different forms of zonular attachments are studied to determine which may most closely mimic the physiological form by comparing stress and displacement fields with simulated shape changes to accommodation in living lenses. The results indicate that for models to mimic accommodation in living eyes, the anterior and posterior parts of the zonule need independent force directions. Choice of material properties affects which theory of accommodation is supported. PMID:27507665
Angular and linear fields of view of Galilean telescopes and telemicroscopes.
Katz, Milton
2007-06-01
The calculation of the angular fields of view (FOVs) of Galilean telescopes generally necessitates the calculation of the pupils and ports. This, in turn, requires knowledge of the optical design of the telescope, in particular, the focal lengths or powers of the objective and ocular lenses. Equations for finding the FOV that obviate the need to calculate pupils and ports, or even to know the lens powers of the telescope, are presented in this article. The equations can be used to find the FOVs in image space of real Galilean telescopes of known magnification, merely by measuring the distance between the objective and ocular lenses and the diameter of the objective lens. The equations include the effects of eye pupil diameter and eye relief. Linear FOVs (LFOVs) of Galilean telemicroscopes are similarly determined. Two image space angular FOV equations were derived: (1) an equation to determine the angular FOVs of a telescope with various amounts of vignetting and eye relief; and (2) an equivalent equation for the LFOVs of telescopes fitted with lens caps for near vision. The FOV increases linearly with increasing vignetting. Increasing the eye relief results in a nonlinear decrease in the FOV, shown as a fraction of the normalized value for zero eye relief. Decrements in the FOVs with increasing eye relief as a fraction of the normalized field angle when the eye relief = 0 are shown to be constant regardless of the vignetting level. A transition of the objective lens from field stop to aperture stop occurs when the eye pupil diameter exceeds the diameter of the objective lens divided by the magnification. Equations have been derived for Galilean telescopes and telemicroscopes that make it unnecessary to find pupils and ports, or to know the powers of the lenses. They provide a direct and simple evaluation of angular and LFOVs as functions of magnification, objective lens diameter, eye pupil diameter, eye relief, and vignetting, and enable comparisons of actual telescopes.
Errors Associated with IOLMaster Biometry as a Function of Internal Ocular Dimensions
Faria-Ribeiro, Miguel; Lopes-Ferreira, Daniela; López-Gil, Norberto; Jorge, Jorge; González-Méijome, José Manuel
2014-01-01
Purpose To evaluate the error in the estimation of axial length (AL) with the IOLMaster partial coherence interferometry (PCI) biometer and obtain a correction factor that varies as a function of AL and crystalline lens thickness (LT). Methods Optical simulations were produced for theoretical eyes using Zemax-EE software. Thirty-three combinations including eleven different AL (from 20 mm to 30 mm in 1 mm steps) and three different LT (3.6 mm, 4.2 mm and 4.8 mm) were used. Errors were obtained comparing the AL measured for a constant equivalent refractive index of 1.3549 and for the actual combinations of indices and intra-ocular dimensions of LT and AL in each model eye. Results In the range from 20 mm to 30 mm AL and 3.6–4.8 mm LT, the instrument measurements yielded an error between −0.043 mm and +0.089 mm. Regression analyses for the three LT condition were combined in order to derive a correction factor as a function of the instrument measured AL for each combination of AL and LT in the theoretical eye. Conclusions The assumption of a single “average” refractive index in the estimation of AL by the IOLMaster PCI biometer only induces very small errors in a wide range of combinations of ocular dimensions. Even so, the accurate estimation of those errors may help to improve accuracy of intra-ocular lens calculations through exact ray tracing, particularly in longer eyes and eyes with thicker or thinner crystalline lenses. PMID:24766863
Ayaki, Masahiko; Negishi, Kazuno; Suzukamo, Yoshimi; Tsubota, Kazuo
2015-04-01
This study compared post-operative quality of life and sleep according to the type of cataract opacity and color of the implanted intra-ocular lens (IOL). This is a cohort study and participants were 206 patients (average age 74.1 years) undergoing cataract surgery with the implantation of a clear ultra-violet (UV)-blocking IOL (C) or a yellow blue-light-blocking IOL (Y). Participants were evaluated using the National Eye Institute Visual Function Questionnaire (VFQ-25) and Pittsburgh Sleep Quality Index (PSQI) before surgery and 2 and 7 months after surgery. Changes in sub-scale scores of VFQ-25 and PSQI were compared. Sub-scale analyses for improvement after surgery revealed significant differences in ocular pain scores on the VFQ-25 (Y>C; the higher the score, the better the outcome). Furthermore, there were significant differences between the two IOLs in terms of the sleep latency score (C>Y) and sleep disturbances score (C>Y). A posterior sub-capsular cataract was significantly correlated with improvements in ocular pain and sleep latency scores. These effects were successfully represented by the change in scores rather than absolute post-operative scores because individual standard of response may often change after intervention, recognized as a response shift phenomenon in patient-reported outcome study. Regarding seasonal differences, patients who had surgery in summer exhibited relatively better sleep quality than those who had surgery in winter. Analysis of sub-scales of health indices demonstrated characteristic prognoses for each IOL and cataract type. Cataract surgery may potentially contribute to systemic health in older adults.
Errors associated with IOLMaster biometry as a function of internal ocular dimensions.
Faria-Ribeiro, Miguel; Lopes-Ferreira, Daniela; López-Gil, Norberto; Jorge, Jorge; González-Méijome, José Manuel
2014-01-01
To evaluate the error in the estimation of axial length (AL) with the IOLMaster partial coherence interferometry (PCI) biometer and obtain a correction factor that varies as a function of AL and crystalline lens thickness (LT). Optical simulations were produced for theoretical eyes using Zemax-EE software. Thirty-three combinations including eleven different AL (from 20mm to 30mm in 1mm steps) and three different LT (3.6mm, 4.2mm and 4.8mm) were used. Errors were obtained comparing the AL measured for a constant equivalent refractive index of 1.3549 and for the actual combinations of indices and intra-ocular dimensions of LT and AL in each model eye. In the range from 20mm to 30mm AL and 3.6-4.8mm LT, the instrument measurements yielded an error between -0.043mm and +0.089mm. Regression analyses for the three LT condition were combined in order to derive a correction factor as a function of the instrument measured AL for each combination of AL and LT in the theoretical eye. The assumption of a single "average" refractive index in the estimation of AL by the IOLMaster PCI biometer only induces very small errors in a wide range of combinations of ocular dimensions. Even so, the accurate estimation of those errors may help to improve accuracy of intra-ocular lens calculations through exact ray tracing, particularly in longer eyes and eyes with thicker or thinner crystalline lenses. Copyright © 2013 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.
Kuc, Christopher J; Lebow, Kenneth A
2018-06-13
This article will examine the current literature, as it relates to contact lens discomfort (CLD) secondary to contact lens solutions. The reader will better understand the characteristics of contact lenses, as they uniquely interact with each type of contact lens solution and also gain a better comprehension of the components of contact lens solution such as preservatives, surfactants, and chelating agents, which may contribute to discomfort. By investigating corneal staining theory and the mechanisms that contribute to its presence, the reader will gain insight into this clinical finding, which relates to selection of contact lens solutions. The FDA standards for testing solutions and how this relates to contact lens keratitis will also be appraised in regards to current ISO recommendations. Finally, better selection of multipurpose contact lens solution (MPS) and hydrogen peroxide-based solutions for patients should be accessible to the clinician based on this review and preexisting clinical findings or diagnoses. A review of current published literature from peer reviewed journals and online journals was conducted to gain an understanding of contact lens solution's impact on contact lens discomfort. Many studies have been conducted comparing comfort between various types of contact lens solutions. It is challenging to decipher this information and apply it clinically when selecting solutions for patients. By comparing solution components, how contact lens solutions interact with different types of lenses, keratitis related to contact lenses, and preexisting ocular conditions, this review will improve a clinician's ability to eliminate CLD.
Racial differences in ocular oxidative metabolism: implications for ocular disease.
Siegfried, Carla J; Shui, Ying-Bo; Holekamp, Nancy M; Bai, Fang; Beebe, David C
2011-07-01
To compare the Po(2) distribution in different regions in the eyes of patients undergoing intraocular surgery. Before initiation of intraocular cataract and/or glaucoma surgery, an optical oxygen sensor was introduced into the anterior chamber via a peripheral corneal paracentesis. The tip of the flexible fiberoptic probe was positioned by the surgeon for 3 measurements in all patients: (1) near the central corneal endothelium, (2) in the mid-anterior chamber, and (3) in the anterior chamber angle. In patients scheduled to undergo cataract extraction, Po(2) was also measured (4) at the anterior lens surface and (5) in the posterior chamber just behind the iris. Oxygen measurements at the 5 locations were compared using a 2-tailed unpaired t test and multivariate regression. The Po(2) value was significantly higher in African American patients at all 5 locations compared with Caucasian patients. Adjusting for age increased the significance of this association. Adjusting for race revealed that age was associated with increased Po(2) beneath the central cornea. Racial differences in oxygen levels in the human eye reflect an important difference in oxidative metabolism in the cornea and lens and may reflect differences in systemic physiologic function. Increased oxygen or oxygen metabolites may increase oxidative stress, cell damage, intraocular pressure, and the risk of developing glaucoma. Oxygen use by the cornea decreases with age.
Parekh, Mohit; Ferrari, Stefano; Di Iorio, Enzo; Barbaro, Vanessa; Camposampiero, Davide; Karali, Marianthi; Ponzin, Diego; Salvalaio, Gianni
2012-06-12
Enucleation is the process of retrieving the ocular globe from a cadaveric donor leaving the rest of the globe undisturbed. Excision refers to the retrieval of ocular tissues, especially cornea, by cutting it separate from the ocular globe. Evisceration is the process of removing the internal organs referred here as retina. The ocular globe consists of the cornea, the sclera, the vitreous body, the lens, the iris, the retina, the choroid, muscles etc (Suppl. Figure 1). When a patient is suffering from corneal damage, the cornea needs to be removed and a healthy one must be transplanted by keratoplastic surgeries. Genetic disorders or defects in retinal function can compromise vision. Human ocular globes can be used for various surgical procedures such as eye banking, transplantation of human cornea or sclera and research on ocular tissues. However, there is little information available on human corneal and retinal excision, probably due to the limited accessibility to human tissues. Most of the studies describing similar procedures are performed on animal models. Research scientists rely on the availability of properly dissected and well-conserved ocular tissues in order to extend the knowledge on human eye development, homeostasis and function. As we receive high amount of ocular globes out of which approximately 40% (Table 1) of them are used for research purposes, we are able to perform huge amount of experiments on these tissues, defining techniques to excise and preserve them regularly. The cornea is an avascular tissue which enables the transmission of light onto the retina and for this purpose should always maintain a good degree of transparency. Within the cornea, the limbus region, which is a reservoir of the stem cells, helps the reconstruction of epithelial cells and restricts the overgrowth of the conjunctiva maintaining corneal transparency and clarity. The size and thickness of the cornea are critical for clear vision, as changes in either of them could lead to distracted, unclear vision. The cornea comprises of 5 layers; a) epithelium, b) Bowman's layer, c) stroma, d) Descemet's membrane and e) endothelium. All layers should function properly to ensure clear vision(4,5,6). The choroid is the intermediate tunic between the sclera and retina, bounded on the interior by the Bruch's membrane and is responsible for blood flow in the eye. The choroid also helps to regulate the temperature and supplies nourishment to the outer layers of the retina(5,6). The retina is a layer of nervous tissue that covers the back of the ocular globe (Suppl. Figure 1) and consists of two parts: a photoreceptive part and a non-receptive part. The retina helps to receive the light from the cornea and lens and converts it into the chemical energy eventually transmitted to the brain with help of the optic nerve(5,6). The aim of this paper is to provide a protocol for the dissection of corneal and retinal tissues from human ocular globes. Avoiding cross-contamination with adjacent tissues and preserving RNA integrity is of fundamental importance as such tissues are indispensable for research purposes aimed at (i) characterizing the transcriptome of the ocular tissues, (ii) isolating stem cells for regenerative medicine projects, and (iii) evaluating histological differences between tissues from normal/affected subjects. In this paper we describe the technique we currently use to remove the cornea, the choroid and retinal tissues from an ocular globe. Here we provide a detailed protocol for the dissection of the human ocular globe and the excision of corneal and retinal tissues. The accompanying video will help researchers to learn an appropriate technique for the retrieval of precious human tissues which are difficult to find regularly.
Visual outcomes and prognostic factors in open-globe injuries.
Fujikawa, Azusa; Mohamed, Yasser Helmy; Kinoshita, Hirofumi; Matsumoto, Makiko; Uematsu, Masafumi; Tsuiki, Eiko; Suzuma, Kiyoshi; Kitaoka, Takashi
2018-06-08
Ocular trauma is an important cause of visual loss worldwide. Improvements in our knowledge of the pathophysiology and management of ocular trauma during the past 30 years, in conjunction with advances in the instrumentation and techniques of ocular surgery, have improved the efficacy of vitreoretinal surgery in injured eyes. The aim of the current study was to determine the visual outcomes and prognostic factors of open-globe injuries in the Japanese population. Retrospective study of 59 eyes of 59 patients presented with open globe injuries between September 2008 and March 2014 at Nagasaki University Hospital was conducted. Demographic factors including age, gender, and clinical data such as cause of injury, presenting visual acuity (VA), location of injury, type of injury, lens status, presence of intraocular foreign body, types of required surgeries, and final VA were recorded. According to the classification of Ocular Trauma Classification Group, wound location was classified into three zones. Chi-square test was used to compare presented data. Out of the 59 patients, 46 were placed in the Light Perception (LP) group, and 13 were placed in the No Light Perception (NLP) group. Work-related trauma was the most common cause (27 eyes) followed by falls (19eyes). Work-related trauma was common in males (P = 0.004), while falls was significantly common in females (P = 0.00001). Zone III injuries had statistically significantly poor prognostic factor compared to other zones (P = 0.04). All cases of NLP group (100%) presented with rupture globe. Poor VA at first visit (P = 0.00001), rupture globe (P = 0.026), history of penetrating keratoplasty (PK) (P = 0.017), retinal detachment (RD) (P = 0.0001), vitreous hemorrhage (VH) (P = 0.044), and dislocation of crystalline lens (P = 0.0003) were considered as poor prognostic factors. Poor VA at first visit, rupture globe, zone III injuries, history of penetrating keratoplasty, RD, VH, and dislocation of crystalline lens were found to be poor prognostic factors. PPV had a good prognostic value in open globe injuries associated with posterior segment involvement.
Bourla, Dan Haim; Laron, Zvi; Snir, Moshe; Lilos, Pearl; Weinberger, Dov; Axer-Siegel, Ruth
2006-07-01
To evaluate the ocular dimensions in patients with primary growth hormone receptor insensitivity (Laron syndrome [LS]) and to study the effect of supplemental insulinlike growth factor I (IGF-I) on ocular growth. Retrospective case series. Twelve patients with LS, 8 untreated (LS group) and 4 treated (LS-T group) with supplemental IGF-I, and 30 healthy controls. Ocular dimensions and refraction were measured, and a full ophthalmologic examination was performed. Differences in the average ocular dimension data among IGF-I-treated patients, untreated ones, and controls. The average axial length of eyes in the LS group was 21.94 mm (standard deviation [SD], 0.81). Corresponding values for the LS-T and control group eyes were 22.53 mm (SD, 1.74) and 23.20 mm (SD, 1.35) respectively. The average anterior chamber depth of eyes in the LS group was 2.55 mm (SD, 0.26). Corresponding values for eyes in the LS-T and control groups were 3.48 mm (SD, 0.09) and 3.84 mm (SD, 0.16) respectively. The average lens thickness of eyes in the LS group was 4.56 mm (SD, 0.36). Corresponding values for the LS-T and control groups were 3.77 mm (SD, 0.23) and 3.51 mm (SD, 0.25), respectively. The average corneal curvature of eyes in the LS group was 46.9 diopters (D) (SD, 2.32). Corresponding values for the LS-T and control groups were 47.6 D (SD, 2.83) and 44.4 D (SD, 1.5), respectively. Insulinlike growth factor I seems to be an important regulator of ocular growth as documented in patients with primary growth hormone insensitivity. The mechanism of this observation should be investigated further.
Nanoporous Membrane Immunosensor
2000-01-01
but not intended to be limited to blood, saliva, ocular lens fluid, cerebral spinal fluid, sweat, urine, milk, ascites fluid, mucous, synovial fluid...such as rubella-IgG and rubella-IgM; antibodies to toxoplasmosis , such as toxoplasmosis IgG(Toxo-IgG) and toxoplasmosis IgM (Toxo-IgM); testosterone
Photochemical mechanisms of ocular photic injury (Abstract Only)
NASA Astrophysics Data System (ADS)
Stuck, Bruce E.; Lund, David J.; Zuclich, Joseph A.
2000-03-01
Mechanisms of photic injury to the eye can be categorized as photochemical, photothermal or photodistruptive. Exposure wavelength, exposure duration, ocular tissue characteristics and response criteria are key factors in the delineation of the ocular injury mechanisms. Depending on the exposure condition, one or all of the laser-tissue interaction mechanisms can be involved. Although photic injury to the eye was initially assumed to involve thermal mechanisms, more recent research has demonstrated that ocular effects can be produced by light exposure without a significant retinal temperature rise. Photochemical mechanisms are also implicated in UV photic injury to the cornea and lens. Exposure of the retina to short visible wavelengths for prolonged durations results in photochemical retinal damage with negligible localized retinal temperature elevation. For exposure conditions where photochemical mechanisms are dominate, the reciprocity of irradiance and exposure duration is apparent. The latency until observation of a photochemical lesion is often 24-48 hours whereas a thermal lesion is observed immediately or within a few hours after the exposure. Action spectra for photochemical injury to the eye are discussed in the context of ocular injury thresholds and current permissible exposure limits.
Owens, S L; Lam, S; Tessler, H H; Deutsch, T A
1993-04-01
Late endophthalmitis, due to Propionibacterium acnes, developed in three patients following uncomplicated extracapsular cataract extraction and posterior chamber intraocular lens (PC-IOL) insertion. Cultures from the capsular bag yielded P. acnes in all three. With topical anesthesia and through an anterior chamber paracentesis, culture specimens were taken from and clindamycin irrigated into the capsular bag. Filtered 100% oxygen was introduced into the anterior chamber in two; the third also received an injection of gentamicin and dexamethasone into the capsular bag. After treatment, two patients received oral antibiotics; one received hyperbaric oxygen therapy. Visual acuity was improved and inflammation reduced in all three. However, after treatment, ocular toxic effects due to clindamycin were suspected in one. This approach offers several clear advantages, including topical anesthesia, outpatient management, elimination of the need for vitrectomy, and retention of the intraocular lens (IOL).
Single-lens stereovision system using a prism: position estimation of a multi-ocular prism.
Cui, Xiaoyu; Lim, Kah Bin; Zhao, Yue; Kee, Wei Loon
2014-05-01
In this paper, a position estimation method using a prism-based single-lens stereovision system is proposed. A multifaced prism was considered as a single optical system composed of few refractive planes. A transformation matrix which relates the coordinates of an object point to its coordinates on the image plane through the refraction of the prism was derived based on geometrical optics. A mathematical model which is able to denote the position of an arbitrary faces prism with only seven parameters is introduced. This model further extends the application of the single-lens stereovision system using a prism to other areas. Experimentation results are presented to prove the effectiveness and robustness of our proposed model.
Nagaraj, R H; Sell, D R; Prabhakaram, M; Ortwerth, B J; Monnier, V M
1991-11-15
Pentosidine is a recently discovered protein crosslink, involving lysine and arginine residues linked together in an imidazo [4,5,6] pyridinium ring formed by a 5-carbon sugar during nonenzymatic browning (Maillard reaction). The presence of high ascorbate levels in the human lens and its ability to undergo nonenzymatic browning led us to investigate pentosidine formation in the aging human lens. Incubation of lens crystallins with ascorbate and its oxidation products dehydroascorbate and 2,3-diketogulonate leads progressively to the formation of pentosidine crosslinks in the presence of oxygen. Under nitrogen, however, pentosidine forms only from 2,3-diketogulonate or xylosone, a degradation product of 2,3-diketogulonate. A high correlation between pentosidine crosslinks and the degree of lens pigmentation is noted in cataractous lenses. Pentosidine is found to be primarily associated with alpha-crystallin fractions of 300-5000 kDa. These results suggest that redox imbalance in cellular senescent systems such as the ocular lens may lead to irreversible ascorbate oxidation and protein crosslinking by xylosone. This mechanism may play an important role in the pathogenesis of "brunescent" cataracts.
The enhancement of biological ocular UV radiation on beaches compared to the radiation on grass.
Liu, Guang-Cong; Wang, Fang; Gao, Yan-Yan; Yang, Zheng; Hu, Li-Wen; Gao, Qian; Ri, Jun-Chol; Liu, Yang
2014-12-01
The influence of albedo on ocular UV exposure has seldom been reported. This paper aimed to explore the enhancement effect on measured ocular UV radiation due to a sand surface compared to measured ocular UV radiation due to a grass surface. We measured ambient and ocular UV radiation over the beach and grass surface in Sanya City of China (18.4°N, 109.7°E). The experimental apparatus was composed of a manikin and a dual-detector spectrometer. Integration of both UVA and UVB radiation was used to denote UV radiation. Then biologically effective ocular UVB radiation (UVBE) and the ratios of UVBE of two surfaces were calculated. Maximum of ocular UV radiation versus time over the two surfaces is bimodal. UVBE on the beach is significantly larger than UVBE on the sand, and UVBE peaked at different solar elevation angle (SEA) over the two surfaces (about 53° and 40° on the beach and grass, respectively, according to Bayesian regression). The maximum of ocular UVBE ratios is greater than two, which peaked SEA was about 50°. One hour's cumulative radiation under sunny weather exceeds thresholds for photokeratitis, conjunctivitis and lens damage. Higher albedo significantly increased biological ocular UV radiation. Tourists on tropical beaches should take protective measures and avoid facing the sun directly, especially when SEA is around 50°. Copyright © 2014 Elsevier B.V. All rights reserved.
Editorial: ERCP-Related Radiation Cataractogenesis: Is It Time to Be Concerned?
Mekaroonkamol, Parit; Keilin, Steven
2017-05-01
With the growing number of fluoroscopic guided endoscopic procedures, radiation-related risk needs to be further assessed. Recent evidence indicates that radiation cataractogenesis occurs at a lower dose threshold than previously believed. While body aprons and thyroid shields are well-established standard protection during fluoroscopy, ocular safety and the use of protective eyewear are not as well defined. This prospective study answered two important questions: Does the standard body dosimeter provide an accurate ocular dosimetry? And what is the time of fluoroscopy needed to warrant using lens protection? It also raises the question whether current guidelines need to be updated.
Morgan, Philip B; Chamberlain, Paul; Moody, Kurt; Maldonado-Codina, Carole
2013-06-01
To evaluate the performance of a silicone hydrogel daily disposable lens in neophyte subjects over 12 months. Seventy four subjects with no previous contact lens experience were randomised to wear narafilcon A (1 DAY ACUVUE(®) TruEye™) lenses (LW group) or to wear no contact lenses (NLW group) for 12 months. Biomicroscopy (performed by a masked investigator), visual acuity and subjective response scores were recorded at an initial visit and six follow-up visits, in addition to lens fit and surface evaluation for the LW group. Comfort was recorded with SMS messaging. Fifteen of the LW group discontinued before the end of the study, compared with six of the NLW group. Measured visual acuity was about half a line better for the NLW group as these subjects were provided with their full sphero-cylindrical over-refraction, compared to the LW group in their best spherical corrected contact lenses; subjective scores for vision were similar for the two groups. Bulbar conjunctival hyperaemia, limbal hyperaemia, corneal staining, conjunctival staining and papillary conjunctivitis were clinically equivalent for the two groups whereas conjunctival staining was higher in the LW group. Comfort scores assessed by SMS were equivalent for the LW and NLW groups; there was a measurable improvement in comfort during the first month of wear for the LW group. This work has demonstrated that modern soft lenses (narafilcon A daily disposable silicone hydrogel lenses) offer an excellent, comfortable form of vision correction, and are able to exhibit minimal alterations to ocular physiology. Copyright © 2012 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
Influence of Gravity on Ocular Lens Position.
Lister, Lucas J; Suheimat, Marwan; Verkicharla, Pavan K; Mallen, Edward A H; Atchison, David A
2016-04-01
We determined whether human ocular lens position is influenced by gravity. Anterior chamber depth (ACD) and lens thickness (LT) were determined with a Haag-Streit Lenstar LS900 for right eyes of participants in two age groups, with a young group of 13 participants aged 18 to 21 years (mean, 21 years; SD, 1 year) and an older group of 10 participants aged 50 to 63 years (mean, 58 years; SD, 4 years). There were two sessions for each participant separated by at least 48 hours, with one session for the usual upright head position and one session for a downwards head position. In a session, testing was done for minimum accommodation followed by testing at maximum accommodation. A drop of 2% pilocarpine nitrate was instilled, and testing was repeated after 30 minutes under minimum and maximum accommodation conditions. Gravity, manipulated through head posture, affected ACD for young adult and older adult groups but mean effects were only small, ranging from 0.04 to 0.12 mm, and for the older group required the instillation of an accommodation-stimulating drug. Gravity had a weakly significant effect on LT for the young group without accommodation or a drug, but the effect was small at 0.04 ± 0.06 mm (mean ± SD, P = 0.04). There is a small but real effect of gravity on crystalline lens position, manifested as reduction in ACD at high levels of accommodative effort with the head in a downwards position. This provides evidence of the ability of zonules to slacken during strong accommodation.
Skorobohach, Brian J; Hendrix, Diane V H
2003-06-01
A unilateral scleral staphyloma in an 18-month-old, female spayed Domestic Short-haired cat was treated with excision, primary closure and fascial graft. Other ocular abnormalities noted on examination included iris coloboma, anterior cortical cataract, focal lens equator flattening and retinal dysplasia. The staphyloma was presumed to be congenital in origin.
Thermal safety of ultrasound-enhanced ocular drug delivery: A modeling study
Nabili, Marjan; Geist, Craig; Zderic, Vesna
2015-01-01
Purpose: Delivery of sufficient amounts of therapeutic drugs into the eye for treatment of various ocular diseases is often a challenging task. Ultrasound was shown to be effective in enhancing ocular drug delivery in the authors’ previous in vitro and in vivo studies. Methods: The study reported here was designed to investigate the safety of ultrasound application and its potential thermal effects in the eye using PZFlex modeling software. The safety limit in this study was set as a temperature increase of no more than 1.5 °C based on regulatory recommendations and previous experimental safety studies. Acoustic and thermal specifications of different human eye tissues were obtained from the published literature. The tissues of particular interest in this modeling safety study were cornea, lens, and the location of optic nerve in the posterior eye. Ultrasound application was modeled at frequencies of 400 kHz–1 MHz, intensities of 0.3–1 W/cm2, and exposure duration of 5 min, which were the parameters used in the authors’ previous drug delivery experiments. The baseline eye temperature was 37 °C. Results: The authors’ results showed that the maximal tissue temperatures after 5 min of ultrasound application were 38, 39, 39.5, and 40 °C in the cornea, 39.5, 40, 42, and 43 °C in the center of the lens, and 37.5, 38.5, and 39 °C in the back of the eye (at the optic nerve location) at frequencies of 400, 600, 800 kHz, and 1 MHz, respectively. Conclusions: The ocular temperatures reached at higher frequencies were considered unsafe based on current recommendations. At a frequency of 400 kHz and intensity of 0.8 W/cm2 (parameters shown in the authors’ previous in vivo studies to be optimal for ocular drug delivery), the temperature increase was small enough to be considered safe inside different ocular tissues. However, the impact of orbital bone and tissue perfusion should be included in future modeling efforts to determine the safety of this method in the whole orbit especially regarding potential adverse optic nerve heating at the location of the bone. PMID:26429235
Ocular trauma resulting from paintball injury.
Pahk, Patricia J; Adelman, Ron A
2009-04-01
Paintball-related ocular injuries result in severe damage and loss of vision. Despite efforts to increase public awareness and improve safety features, the incidence of eye injuries has increased over time. We examined the characteristics and ocular effects of paintball injury at our tertiary referral center. Retrospective review of charts of patients with paintball injury between 1998-2005. Fourteen patients were evaluated for paintball injury; 13 (93%) were male and one (7%) was female. Average age was 17 years (range from 9 to 30). Thirteen patients (95%) did not wear eye protection; one is unknown. Injuries occurred while playing paintball in three patients (21%); ten (71%) were injured in either accidental (four patients) or intentional (six patients) shootings not associated with play. Minimum follow-up was 6 weeks, except for one patient who was lost to follow-up. Seven patients (50%) had final visual acuity (VA) better than 20/200, six patients (43%) were 20/200 or worse, and information on one patient was not available. VA, except in one case, improved with treatment. Decreased VA in this case was due to proliferative vitreoretinopathy (PVR). Hyphema was noted in ten patients (71%), vitreous hemorrhage in eight (57%), retinal hemorrhage in six (43%), retinal tear or detachment in six (43%), commotio retinae in six (43%), iris injury in five (36%), keratopathy in four (29%), lens injury in two (14%), subluxation of lens in two (14%), secondary glaucoma in two (14%), open globe/intraocular foreign body (IOFB) in one (7%), choroidal rupture in one (7%), and proliferative vitreoretinopathy (PVR) in one (7%). Ten patients (71%) required intervention (surgery, laser retinopexy or cryotherapy). Paintball trauma results in significant ocular injury and loss of vision. Most injuries occur in unsupervised settings without proper eye protection. Ten patients (71%) were injured in accidental or intentional shootings. Lack of supervision and use of paintball materials as assault weapons make the risk for ocular injury more significant. Improved safety features of paintball equipment, along with continued education of proper eye protection, may reduce the incidence of severe ocular injuries.
Uchio, Eiichi; Kadonosono, Kazuaki; Matsuoka, Yasuhiro; Goto, Satoru
2004-02-01
To determine the physical and mechanical conditions of an impacting air bag that would rupture an eye with a transsclerally fixated posterior chamber intraocular lens (IOL). Numerical simulation study on a computer. Simulations in a model human eye were performed with a computer using the finite element analysis program PAM-CRASH (Nihon ESI). The air bag was set to impact the surface of an eye with a transsclerally fixated posterior chamber IOL at various velocities. The tensile force limit of a 10-1 polypropylene suture was assumed to be 0.16 N, which is specified in the U.S. Pharmacopeia XXII. At the lowest velocity of 20.0 m/s, 10-0 polypropylene sutures were not likely to break. Sutures fixating the IOL might break and a corneoscleral incision was likely to open after 0.3 second at the medium impacting velocity (30 m/s). Suture rupture was very likely at the highest velocity (40 m/s) since the tensile force on the sutures continuously exceeded the breaking force after the impact. In an eye with a transsclerally fixated posterior chamber IOL, severe ocular trauma can be caused by an air bag at high velocity. Small individuals such as elderly women are at greater risk for air-bag ocular injury. Further research on modifying air-bag design and deployment is important to minimize the risk for ocular injury.
Test and evaluation of the 2.4-micron photorefractor ocular screening system
NASA Technical Reports Server (NTRS)
Richardson, J. R.
1985-01-01
An improved 2.4-m photorefractor ocular screening system was tested and evaluated. The photorefractor system works on the principal of obtaining a colored photograph of both human eyes; and, by analysis of the retinal reflex images, certain ocular defects can be detected such a refractive error, strabismus, and lens obstructions. The 2.4-m photorefractory system uses a 35-mm camera with a telephoto lens and an electronic flash attachment. Retinal reflex images obtained from the new 2.4-m system are significantly improved over earlier systems in image quality. Other features were also improved, notably portability and reduction in mass. A total of 706 school age children were photorefracted, 211 learning disabled and 495 middle school students. The total students having abnormal retinal reflexes were 156 or 22 percent, and 133 or 85 percent of the abnormal had refractive error indicated. Ophthalmological examination was performed on 60 of these students and refractive error was verified in 57 or 95 percent of those examined. The new 2.4-m system has a NASA patent pending and is authorized by the FDA. It provides a reliable means of rapidly screening the eyes of children and young adults for vision problems. It is especially useful for infants and other non-communicative children who cannot be screened by the more conventional methods such as the familiar E chart.
Estrellas, P S; Alionte, L G; Hobden, J A
2000-03-01
Pseudomonas aeruginosa proteases are thought to be important virulence factors in the pathogenesis of corneal disease. This study examined protease production from two strains of P. aeruginosa responsible for two very distinct clinical diseases: strain Paer1, isolated from a Contact Lens-induced Acute Red Eye (CLARE), and strain KEI 1025, isolated from a corneal ulcer. Strains were compared to a laboratory strain (ATCC 19660) known to produce severe keratitis in experimentally infected mice for protease production and for ocular virulence. Protease production was examined with colorimetric assays, gelatin zymography and western blots. Elastase A activity was quantitated with a staphylolytic assay. Ocular virulence was examined using a mouse scratch model of keratitis. In contrast to strains KEI 1025 or ATCC 19660, Paer1 was unable to produce enzymatically active elastase A, elastase, and protease IV. All three strains produced active alkaline protease. Strains KEI 1025 and ATCC 19660 produced a fulminant keratitis in mice whereas Paer1 produced a mild transient infection. Restoration of elastase activity in Paer1 via genetic complementation did not result in a virulent phenotype. Co-infection of mouse eyes with strains Paer1 and ATCC 19660 resulted in the eventual loss of Paer1 from corneal tissue. These studies suggest that P. aeruginosa elastase A and/or protease IV, but not alkaline protease or elastase, contribute to the ocular virulence of this organism.
Chromostereopsis in "virtual reality" adapters with electrically tuneable liquid lens oculars
NASA Astrophysics Data System (ADS)
Ozolinsh, Maris; Muizniece, Kristine; Berzinsh, Janis
2016-10-01
Chromostereopsis can be sight and feel in "Virtual Reality" adapters, that induces the appearance of color dependant depth sense and, finally, combines this sense with the source conceived depth scenario. Present studies are devoted to investigation the induced chromastereopsis when using adapted "Virtual Reality" frame together with mobile devices as smartphones. We did observation of composite visual stimuli presented on the high spatial resolution screen of the mobile phone placed inside a portable "Virtual Reality" adapter. Separated for the left and right eyes stimuli consisted of two areas: a) identical for both eyes color chromostereopsis part, and b) additional conventional color neutral random-dot stereopsis part with a stereodisparity based on the horizontal shift of a random-dot segment in images for the left and right eyes, correspondingly. The observer task was to equalize the depth sense for neutral and colored stimuli areas. Such scheme allows to determine actual observed chromostereopsis disparity value versus eye stimuli color difference. At standard observation conditions for adapter with +2D ocular lenses for mobile red-blue stimuli, the perceptual chromostereopsis depth sensitivity on color difference was linearly approximated with a slope SChS ≈ 2.1[arcmin/(Labcolor difference)] for red-blue pairs. Additional to standard application in adapter the tuneable "Varioptic" liquid lens oculars were incorporated, that allowed stimuli eye magnification, vergence and disparity values control electrically.
Antioxidant delivery pathways in the anterior eye.
Umapathy, Ankita; Donaldson, Paul; Lim, Julie
2013-01-01
Tissues in the anterior segment of the eye are particular vulnerable to oxidative stress. To minimise oxidative stress, ocular tissues utilise a range of antioxidant defence systems which include nonenzymatic and enzymatic antioxidants in combination with repair and chaperone systems. However, as we age our antioxidant defence systems are overwhelmed resulting in increased oxidative stress and damage to tissues of the eye and the onset of various ocular pathologies such as corneal opacities, lens cataracts, and glaucoma. While it is well established that nonenzymatic antioxidants such as ascorbic acid and glutathione are important in protecting ocular tissues from oxidative stress, less is known about the delivery mechanisms used to accumulate these endogenous antioxidants in the different tissues of the eye. This review aims to summarise what is currently known about the antioxidant transport pathways in the anterior eye and how a deeper understanding of these transport systems with respect to ocular physiology could be used to increase antioxidant levels and delay the onset of eye diseases.
Guillon, Michel; Maïssa, Cécile
2010-12-01
The objective of the investigation was to show that, because of their overall properties, Acuvue® Oasys™ with Hydraclear® Plus brand (senofilcon A) silicone hydrogel contact lenses achieve excellent ocular tissue tolerance during long-term daily wear. The 2-year investigation was a prospective daily wear analysis of Acuvue® Oasys™ with Hydraclear® Plus (senofilcon A) silicone hydrogel contact lenses replaced every 2 weeks and used in conjunction with a representative range of care systems. The 2-year results compared with the subjects' baseline ocular status on entering the study revealed: The quantification of the effects on the ocular tissues of 2 years of daily wear of senofilcon A, by mainly previously successful daily soft contact lens wearers, showed an excellent biocompatibility. The results support the hypothesis that senofilcon A contact lenses, when worn on a 2-week daily wear regimen, maintain excellent long-term ocular tissue tolerance. Copyright © 2010 American Optometric Association. Published by Elsevier Inc. All rights reserved.
Therapeutic use of mini-scleral lenses in a patient with Graves' ophthalmopathy.
Harthan, Jennifer S
2014-01-01
Patients with Graves' ophthalmopathy can be very challenging to manage secondary to the complex nature of their disease presentation. Patients may present with a variety of ocular findings including: lid retraction, periorbital and lid swelling, chemosis, conjunctival hyperemia, proptosis, optic neuropathy, restrictive myopathy, exposure keratopathy and/or keratoconjunctivitis sicca. Mini-scleral and scleral lens designs have been important in the management of irregular and regular corneas, and in the therapy of ocular surface diseases. We present here the case of a 48-year-old Caucasian male who had been diagnosed with Graves' ophthalmopathy 13 years earlier. With significant ocular surface staining and over ten diopters of astigmatism, the patient had never been able to wear contact lenses comfortably. After being fit with the Mini-Scleral Design™ lenses, his vision improved to 20/25 OU, his ocular surface improved, and overall quality of vision increased. Copyright © 2012 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ciller, Carlos, E-mail: carlos.cillerruiz@unil.ch; Ophthalmic Technology Group, ARTORG Center of the University of Bern, Bern; Centre d’Imagerie BioMédicale, University of Lausanne, Lausanne
Purpose: Proper delineation of ocular anatomy in 3-dimensional (3D) imaging is a big challenge, particularly when developing treatment plans for ocular diseases. Magnetic resonance imaging (MRI) is presently used in clinical practice for diagnosis confirmation and treatment planning for treatment of retinoblastoma in infants, where it serves as a source of information, complementary to the fundus or ultrasonographic imaging. Here we present a framework to fully automatically segment the eye anatomy for MRI based on 3D active shape models (ASM), and we validate the results and present a proof of concept to automatically segment pathological eyes. Methods and Materials: Manualmore » and automatic segmentation were performed in 24 images of healthy children's eyes (3.29 ± 2.15 years of age). Imaging was performed using a 3-T MRI scanner. The ASM consists of the lens, the vitreous humor, the sclera, and the cornea. The model was fitted by first automatically detecting the position of the eye center, the lens, and the optic nerve, and then aligning the model and fitting it to the patient. We validated our segmentation method by using a leave-one-out cross-validation. The segmentation results were evaluated by measuring the overlap, using the Dice similarity coefficient (DSC) and the mean distance error. Results: We obtained a DSC of 94.90 ± 2.12% for the sclera and the cornea, 94.72 ± 1.89% for the vitreous humor, and 85.16 ± 4.91% for the lens. The mean distance error was 0.26 ± 0.09 mm. The entire process took 14 seconds on average per eye. Conclusion: We provide a reliable and accurate tool that enables clinicians to automatically segment the sclera, the cornea, the vitreous humor, and the lens, using MRI. We additionally present a proof of concept for fully automatically segmenting eye pathology. This tool reduces the time needed for eye shape delineation and thus can help clinicians when planning eye treatment and confirming the extent of the tumor.« less
Ciller, Carlos; De Zanet, Sandro I; Rüegsegger, Michael B; Pica, Alessia; Sznitman, Raphael; Thiran, Jean-Philippe; Maeder, Philippe; Munier, Francis L; Kowal, Jens H; Cuadra, Meritxell Bach
2015-07-15
Proper delineation of ocular anatomy in 3-dimensional (3D) imaging is a big challenge, particularly when developing treatment plans for ocular diseases. Magnetic resonance imaging (MRI) is presently used in clinical practice for diagnosis confirmation and treatment planning for treatment of retinoblastoma in infants, where it serves as a source of information, complementary to the fundus or ultrasonographic imaging. Here we present a framework to fully automatically segment the eye anatomy for MRI based on 3D active shape models (ASM), and we validate the results and present a proof of concept to automatically segment pathological eyes. Manual and automatic segmentation were performed in 24 images of healthy children's eyes (3.29 ± 2.15 years of age). Imaging was performed using a 3-T MRI scanner. The ASM consists of the lens, the vitreous humor, the sclera, and the cornea. The model was fitted by first automatically detecting the position of the eye center, the lens, and the optic nerve, and then aligning the model and fitting it to the patient. We validated our segmentation method by using a leave-one-out cross-validation. The segmentation results were evaluated by measuring the overlap, using the Dice similarity coefficient (DSC) and the mean distance error. We obtained a DSC of 94.90 ± 2.12% for the sclera and the cornea, 94.72 ± 1.89% for the vitreous humor, and 85.16 ± 4.91% for the lens. The mean distance error was 0.26 ± 0.09 mm. The entire process took 14 seconds on average per eye. We provide a reliable and accurate tool that enables clinicians to automatically segment the sclera, the cornea, the vitreous humor, and the lens, using MRI. We additionally present a proof of concept for fully automatically segmenting eye pathology. This tool reduces the time needed for eye shape delineation and thus can help clinicians when planning eye treatment and confirming the extent of the tumor. Copyright © 2015 Elsevier Inc. All rights reserved.
Ghoreishi, Mohammad; Abdi-Shahshahani, Mehdi; Peyman, Alireza; Pourazizi, Mohsen
2018-02-21
The aim of this study was to determine the correlation between ocular biometric parameters and sulcus-to-sulcus (STS) diameter. This was a cross-sectional study of preoperative ocular biometry data of patients who were candidates for phakic intraocular lens (IOL) surgery. Subjects underwent ocular biometry analysis, including refraction error evaluation using an autorefractor and Orbscan topography for white-to-white (WTW) corneal diameter and measurement. Pentacam was used to perform WTW corneal diameter and measurements of minimum and maximum keratometry (K). Measurements of STS and angle-to-angle (ATA) were obtained using a 50-MHz B-mode ultrasound device. Anterior optical coherence tomography was performed for anterior chamber depth measurement. Pearson's correlation test and stepwise linear regression analysis were used to find a model to predict STS. Fifty-eight eyes of 58 patients were enrolled. Mean age ± standard deviation of sample was 28.95 ± 6.04 years. The Pearson's correlation coefficient between STS with WTW, ATA, mean K was 0.383, 0.492, and - 0.353, respectively, which was statistically significant (all P < 0.001). Using stepwise linear regression analysis, there is a statistically significant association between STS with WTW (P = 0.011) and mean K (P = 0.025). The standardized coefficient was 0.323 and - 0.284 for WTW and mean K, respectively. The stepwise linear regression analysis equation was: (STS = 9.549 + 0.518 WTW - 0.083 mean K). Based on our result, given the correlation of STS with WTW and mean K and potential of direct and essay measurement of WTW and mean K, it seems that current IOL sizing protocols could be estimating with WTW and mean K.
Full-field OCT: applications in ophthalmology
NASA Astrophysics Data System (ADS)
Grieve, Kate; Dubois, Arnaud; Paques, Michel; Le Gargasson, Jean-Francois; Boccara, Albert C.
2005-04-01
We present images of ocular tissues obtained using ultrahigh resolution full-field OCT. The experimental setup is based on the Linnik interferometer, illuminated by a tungsten halogen lamp. En face tomographic images are obtained in real-time without scanning by computing the difference of two phase-opposed interferometric images recorded by a high-resolution CCD camera. A spatial resolution of 0.7 μm × 0.9 μm (axial × transverse) is achieved thanks to the short source coherence length and the use of high numerical aperture microscope objectives. A detection sensitivity of 90 dB is obtained by means of image averaging and pixel binning. Whole unfixed eyes and unstained tissue samples (cornea, lens, retina, choroid and sclera) of ex vivo rat, mouse, rabbit and porcine ocular tissues were examined. The unprecedented resolution of our instrument allows cellular-level resolution in the cornea and retina, and visualization of individual fibers in the lens. Transcorneal lens imaging was possible in all animals, and in albino animals, transscleral retinal imaging was achieved. We also introduce our rapid acquisition full-field optical coherence tomography system designed to accommodate in vivo ophthalmologic imaging. The variations on the original system technology include the introduction of a xenon arc lamp as source, and rapid image acquisition performed by a high-speed CMOS camera, reducing acquisition time to 5 ms per frame.
Palte, Howard D; Gayer, Steven; Arrieta, Esdras; Scot Shaw, Eric; Nose, Izuru; Lee, Elizabete; Arheart, Kristopher L; Dubovy, Sander; Birnbach, David J; Parel, Jean-Marie
2012-07-01
Since Atkinson's original description of retrobulbar block in 1936, needle-based anesthetic techniques have become integral to ophthalmic anesthesia. These techniques are unfortunately associated with rare, grave complications such as globe perforation. Ultrasound has gained widespread acceptance for peripheral nerve blockade, but its translation to ocular anesthesia has been hampered because sonic energy, in the guise of thermal or biomechanical insult, is potentially injurious to vulnerable eye tissue. The US Food and Drug Administration (FDA) has defined guidelines for safe use of ultrasound for ophthalmic examination, but most ultrasound devices used by anesthesiologists are not FDA-approved for ocular application because they generate excessive energy. Regulating agencies state that ultrasound examinations can be safely undertaken as long as tissue temperatures do not increase >1.5°C above physiological levels. Using a rabbit model, we investigated the thermal and mechanical ocular effects after prolonged ultrasonic exposure to single orbital- and nonorbital-rated devices. In a dual-phase study, aimed at detecting ocular injury, the eyes of 8 rabbits were exposed to continuous 10-minute ultrasound examinations from 2 devices: (1) the Sonosite Micromaxx (nonorbital rated) and (2) the Sonomed VuMax (orbital rated) machines. In phase I, temperatures were continuously monitored via thermocouples implanted within specific eye structures (n = 4). In phase II the eyes were subjected to ultrasonic exposure without surgical intervention (n = 4). All eyes underwent light microscopy examinations, followed at different intervals by histology evaluations conducted by an ophthalmic pathologist. Temperature changes were monitored in the eyes of 4 rabbits. The nonorbital-rated transducer produced increases in ocular tissue temperature that surpassed the safe limit (increases >1.5°C) in the lens of 3 rabbits (at 5.0, 5.5, and 1.5 minutes) and cornea of 2 rabbits (both at 1.5 minutes). A secondary analysis of temporal temperature differences between the orbital-rated and nonorbital transducers revealed statistically significant differences (Bonferroni-adjusted P < 0.05) in the cornea at 3.5 minutes, the lens at 2.5 minutes, and the vitreous at 4.0 minutes. Light microscopy and histology failed to elicit ocular injury in either group. The nonorbital-rated ultrasound machine (Sonosite Micromaxx) increases the ocular tissue temperature. A larger study is needed to establish safety. Until then, ophthalmic ultrasound-guided blocks should only be performed with ocular-rated devices.
Palte, Howard D.; Gayer, Steven; Arrieta, Esdras; Shaw, Eric Scot; Nose, Izuru; Lee, Elizabete; Arheart, Kristopher L.; Dubovy, Sander; Birnbach, David J.; Parel, Jean-Marie
2012-01-01
Background Since Atkinson’s original description of retrobulbar block in 1936, needle-based anesthetic techniques have become integral to ophthalmic anesthesia. These techniques are unfortunately associated with rare, grave complications such as globe perforation. Ultrasound has gained widespread acceptance for peripheral nerve blockade but its translation to ocular anesthesia has been hampered because sonic energy, in the guise of thermal or biomechanical insult, is potentially injurious to vulnerable eye tissue. The United States Food and Drug Administration have defined guidelines for safe use of ultrasound for ophthalmic examination but most ultrasound devices used by anesthesiologists are not Food and Drug Administration-approved for ocular application because they generate excessive energy. Regulating agencies state that ultrasound examination can be safely undertaken as long as tissue temperatures do not increase >1.5°C above physiological levels. Methods Using a rabbit model, we investigated the thermal and mechanical ocular effects after prolonged ultrasonic exposure to single orbital and non-orbital-rated devices. In a dual-phase study, aimed at detecting ocular injury, the eyes of 8 rabbits were exposed to continuous 10-minute ultrasound examinations from two devices: 1) the Sonosite Micromaxx (non-orbital-rated) and 2) the Sonomed VuMax (orbital-rated) machines. In Phase I temperatures were continuously monitored via thermocouples implanted within specific eye structures (n=4). In Phase II the eyes were subjected to ultrasonic exposure without surgical intervention (n=4). All eyes underwent light microscopy examinations followed, at different intervals, by histology evaluations conducted by an ophthalmic pathologist. Results Temperature changes were monitored in the eyes of four rabbits. The non-orbital-rated transducer produced increases in ocular tissue temperature that surpassed the safe limit (increases> 1.50C ) in the lens of three rabbits (at 5.0, 5.5 and 1.5 minutes) and cornea of two rabbits (both at 1.5 minutes). A secondary analysis of temporal temperature differences between the orbital-rated and non-orbital transducers revealed statistically significant differences (Bonferroni-adjusted p < 0.05) in the cornea at 3.5 minutes, the lens at 2.5 minutes and the vitreous at 4.0 minutes. Light microscopy and histology failed to elicit ocular injury in either group. Conclusions The non-orbital-rated ultrasound machine (Sonosite Micromaxx) increases the ocular tissue temperature. A larger study is needed to establish safety. Until then, ophthalmic blocks performed with ultrasound should be performed only with ocular-rated devices. PMID:22504211
Ocular ultrasonography focused on the posterior eye segment: what radiologists should know.
De La Hoz Polo, Marcela; Torramilans Lluís, Anna; Pozuelo Segura, Oscar; Anguera Bosque, Albert; Esmerado Appiani, Catalina; Caminal Mitjana, Josep Maria
2016-06-01
Ocular B-mode ultrasonography (US) is an important adjuvant for the clinical assessment of a variety of ocular diseases. When ophthalmoscopy is not possible, mainly due to opacification of the transparent media (e.g., mature cataract or vitreous haemorrhage), US can guide the ophthalmologist in diagnosing disease and choosing treatment. The superficial location and cystic structure of the eye make US ideal for imaging of the eye. Moreover, dynamic study helps distinguish between various conditions that would otherwise be difficult to differentiate in some clinical setting, such as vitreous, retinal, and choroidal detachment. US is also good technique for detecting other pathologic conditions such as lens dislocation, vitreous haemorrhage, asteroid hyalosis, optic disc drusen, and tumors (e.g., choroidal melanoma, metastases, hemangioma). An understanding of the basic anatomy of the eye, the US technique, and common entities that affect the ocular globe will allow radiologists to offer this valuable imaging modality to patients and referring clinicians. This article focuses on the US anatomy and pathologic conditions that affect the posterior ocular segment. • US is specially indicated when ocular fundus cannot be assessed on ophthalmoscopy. • Multipurpose equipment with high-frequency transducers is optimal for imaging the eye. • Ultrasound can reliably depict ocular anatomy and pathology as detachments and tumours. • Dynamic examination is vital for distinguishing certain pathologic conditions as detachments.
Brillouin microscopy: assessing ocular tissue biomechanics.
Yun, Seok Hyun; Chernyak, Dimitri
2018-07-01
Assessment of corneal biomechanics has been an unmet clinical need in ophthalmology for many years. Many researchers and clinicians have identified corneal biomechanics as source of variability in refractive procedures and one of the main factors in keratoconus. However, it has been difficult to accurately characterize corneal biomechanics in patients. The recent development of Brillouin light scattering microscopy heightens the promise of bringing biomechanics into the clinic. The aim of this review is to overview the progress and discuss prospective applications of this new technology. Brillouin microscopy uses a low-power near-infrared laser beam to determine longitudinal modulus or mechanical compressibility of tissue by analyzing the return signal spectrum. Human clinical studies have demonstrated significant difference in the elastic properties of normal corneas versus corneas diagnosed with mild and severe keratoconus. Clinical data have also shown biomechanical changes after corneal cross-linking treatment of keratoconus patients. Brillouin measurements of the crystalline lens and sclera have also been demonstrated. Brillouin microscopy is a promising technology under commercial development at present. The technique enables physicians to characterize the biomechanical properties of ocular tissues.
Cataract Avoidance With Proton Therapy in Ocular Melanomas.
Thariat, Juliette; Jacob, Sophie; Caujolle, Jean-Pierre; Maschi, Celia; Baillif, Stéphanie; Angellier, Gaelle; Mathis, Thibaud; Rosier, Laurence; Carnicer, Adela; Hérault, Joel; Salleron, Julia
2017-10-01
The lens is a radiosensitive organ. Any dose of cephalic irradiation can give rise to radiation-induced cataracts. Contrary to other forms of radiotherapy, proton therapy (PT) can spare all or part of the lens due to accurate dose deposition. We investigated whether a lens-sparing approach was relevant to avoid cataracts in uveal melanoma patients. Patients were referred for PT from onco-ophthalmologists of private and academic institutions. Patients without preexisting cataracts or implants were entered in a prospective database. Dose thresholds responsible for cataracts were investigated in volumes of lens or lens periphery. Lens opacifications and de novo vision-impairing cataracts (VICs) had biannual follow up by ophthalmologists blinded to lens dose. Correlations between dose-volume relationships and VICs were assessed using univariate/multivariate regressions. Between 1991 and 2015, 1696 uveal melanoma patients were consecutively treated with PT. After a median follow up of 48 months, 14.4% and 8.7% of patients had cataracts and VIC within median times of 19 and 28 months, respectively. Median values of mean lens and lens periphery doses were 1.1 (radiobiologically effective [RBE] dose in photon-equivalent grays [GyRBE]) and 6.5 GyRBE, respectively. The lens received no dose in 25% of the patients. At an irradiated lens volume of ≤5%, there was no significantly increased risk for VIC below a dose of 10 GyRBE. A lens-sparing approach is feasible and results not only in reduced need for cataract surgery but also in better fundus-based tumor control. Reassessment of radioprotection rules for lens dose thresholds may follow.
Non-Invasive Early Detection and Molecular Analysis of Low X-ray Dose Effects in the Lens
DOE Office of Scientific and Technical Information (OSTI.GOV)
Goldstein, Lee
This is the Final Progress Report for DOE-funded research project DE-PS02-08ER08-01 titled “Non-Invasive Early Detection and Molecular Analysis of Low X-ray Dose Effects in the Lens”. The project focuses on the effects of low-linear energy transfer (LET) radiation on the ocular lens. The lens is an exquisitely radiosensitive tissue with a highly-ordered molecular structure that is amenable to non-invasive optical study from the periphery. These merits point to the lens as an ideal target for laser-based molecular biodosimetry (MBD). Following exposure to different types of ionizing radiations, the lens demonstrates molecular changes (e.g., oxidation, racemization, crosslinkage, truncation, aggregation, etc.) thatmore » impact the structure and function of the long-lived proteins in the cytosol of lens fiber cells. The vast majority of proteins in the lens comprise the highly-ordered crystallins. These highly conserved lens proteins are amongst the most concentrated and stable in the body. Once synthesized, the crystallins are retained in the fiber cell cytoplasm for life. Taken together, these properties point to the lens as an ideal system for quantitative in vivo MBD assessment using quasi-elastic light scattering (QLS) analysis. In this project, we deploy a purpose-designed non-invasive infrared laser QLS instrument as a quantitative tool for longitudinal assessment of pre-cataractous molecular changes in the lenses of living mice exposed to low-dose low-LET radiation compared to non-irradiated sham controls. We hypothesize that radiation exposure will induce dose-dependent changes in the molecular structure of matrix proteins in the lens. Mechanistic assays to ascertain radiation-induced molecular changes in the lens focus on protein aggregation and gene/protein expression patterns. We anticipate that this study will contribute to our understanding of early molecular changes associated with radiation-induced tissue pathology. This study also affords potential for translational development of molecular biodosimetry instrumentation to assess human exposure to mixed radiation fields.« less
Simulation of Blast Loading on an Ultrastructurally-based Computational Model of the Ocular Lens
2013-10-01
gradient components in the axial ( F22 ) and radial (F11) directions. One can observe the very large deformation (approaching 800%) and 5 Figure 5...and (bottom left) show deformation gradient in axial ( F22 ) and radial (F11) directions. (bottom right) normalized force versus displacement curve for
The Effects of Blue Light on Ocular Health.
ERIC Educational Resources Information Center
Kitchel, Elaine
2000-01-01
This review of the literature examines the effects of blue light (or near UV - ultraviolet), especially that given off by black-light tubes, often used with children with visual impairments. It finds a long-term danger of retinal and lens damage and offers six practical suggestions which emphasize using proper filters and limiting exposure to…
Clinical evaluation of long-term users of two contact lens care preservative systems.
Young, Graeme; Keir, Nancy; Hunt, Chris; Woods, Craig A
2009-03-01
To clinically evaluate long-term users of two different contact lens care preservative systems and to investigate whether prolonged use is associated with an increase in the prevalence of dry eye. Eighty-nine wearers of group IV hydrogel or silicone hydrogel lenses participated in this one-visit, investigator-masked study. Subjects were required to have consistently used a polyhexamethylene biguanide (PHMB) or polyquaternium-1 (PQT) based solution for 2 years. Consistent use was defined as 80% for the past 2 years and 100% for the past year. Clinical assessments included: average and comfortable wear time; overall and end-of-day comfort; signs of dryness, discomfort, burning or stinging, grittiness or scratchiness and visual changes; non-invasive and fluorescein break-up-time; pre-ocular tear film lipids, tear meniscus height, Schirmer and fluorescein clearance tests; limbal and bulbar hyperemia; palpebral roughness; corneal and conjunctival staining; lens front surface wetting; and lens film deposits. Significantly more grittiness or scratchiness was reported by subjects using a PHMB-containing system (67% vs. 44%; P = 0.02). Palpebral roughness and hyperemia were significantly greater in the PHMB group wearing group IV lenses (P = 0.01 and P = 0.05, respectively). Corneal staining was significantly higher in the PHMB users in all four peripheral sectors (P < 0.01). Nasal and temporal conjunctival staining was also significantly higher for users of PHMB-containing systems (P < 0.05). Front surface lens wettability was significantly better for group IV PQT users compared to PHMB users (P = 0.008), with 84% vs. 72%, respectively, with lenses graded by the investigator as having "good" or "excellent" wettability. Significantly higher levels of lens front surface film deposits were noted with PHMB users (P = 0.007), with 58% of group IV lenses treated with PHMB compared with 38% of group IV lenses treated with PQT showing some lens front surface film deposition. No significant differences between the two preservative system groups were noted for the range of dry eye evaluations nor the remaining clinical assessments. Differences in both ocular and lens characteristic were observed between long-term users of two preservative systems used in many contact lens multi-purpose solutions. The findings from this study did not support the hypothesis that prolonged use of PHMB-containing solutions leads to dry eye. Additional studies including a larger sample size and perhaps longer use of the systems could help to further elucidate differences in clinical performance between systems.
Refractive index measurement of the mouse crystalline lens using optical coherence tomography
Chakraborty, Ranjay; Lacy, Kip D.; Tan, Christopher C.; Park, Han na; Pardue, Machelle T.
2014-01-01
In recent years, there has been a growing interest for using mouse models in refractive development and myopia research. The crystalline lens is a critical optical component of the mouse eye that occupies greater than 50% of the ocular space, and significant increases in thickness with age. However, changes in refractive index of the mouse crystalline lens are less known. In this study, we examined the changes in thickness and refractive index of the mouse crystalline lens for two different strains, wild-type (WT) and a nyx mutant (nob) over the course of normal visual development or after form deprivation. Refractive index and lens thickness measurements were made on ex vivo lens using spectral domain optical coherence tomography (SD-OCT). Comparison of refractive index measurements on 5 standard ball lenses using the SD-OCT and their known refractive indices (manufacturer provided) indicated good precision (intra-class correlation coefficient, 0.998 and Bland-Altman coefficient of repeatability, 0.116) of the SD-OCT to calculate mouse lens refractive index ex vivo. During normal visual development, lens thickness increased significantly with age for three different cohorts of mice, aged 4 (average thickness from both eyes; WT: 1.78 ± 0.03, nob: 1.79 ± 0.08 mm), 10 (WT: 2.02 ± 0.05, nob: 2.01 ± 0.04 mm) and 16 weeks (WT: 2.12 ± 0.06, nob: 2.09 ± 0.06 mm, p<0.001). Lens thickness was not significantly different between the two strains at any age (p=0.557). For mice with normal vision, refractive index for isolated crystalline lenses in nob mice was significantly greater than WT mice (mean for all ages; WT: 1.42 ± 0.01, nob: 1.44 ± 0.001, p<0.001). After 4 weeks of form deprivation to the right eye using a skull-mounted goggling apparatus, a thinning of the crystalline lens was observed in both right and left eyes of goggled animals compared to their naïve controls (average from both the right and the left eye) for both strains (p=0.052). In form deprived mice, lens refractive index was significantly different between the goggled animals and non-goggled naïve controls in nob mice, but not in WT mice (p=0.009). Both eyes of goggled nob mice had significantly greater lens refractive index (goggled, 1.49 ± 0.01; opposite, 1.47 ± 0.03) compared to their naïve controls (1.45 ± 0.02, p<0.05). The results presented here suggest that there are genetic differences in the crystalline lens refractive index of the mouse eye, and that the lens refractive index in mice significantly increase with form deprivation. Research applications requiring precise optical measurements of the mouse eye should take these lens refractive indices into account when interpreting SD-OCT data. PMID:24939747
A novel method to predict the dry eye symptoms in new contact lens wearers.
Pult, Heiko; Murphy, Paul J; Purslow, Christine
2009-09-01
Lid wiper epitheliopathy (LWE) and lid parallel conjunctival folds (LIPCOF) give moderate prediction levels for dryness symptoms in experienced contact lens (CL) wearers. This study investigated whether a combination of LWE and LIPCOF plus other tear film tests and subjective evaluation before contact lens fitting was better able to predict CL-induced dry eye (CLIDE) symptoms. Tear meniscus height, non-invasive break-up time (NIBUT), ocular hyperaemia, LIPCOF, phenol red thread test, corneal and conjunctival staining, and LWE of the right eye of 33 new soft CL wearers (12 males, 21 females, median age = 30.5 years; range = 19 to 44) were assessed in a prospective 2-mo longitudinal study. Symptoms were evaluated by the Ocular Surface Disease Index (OSDI) and subjects were grouped according to their response in the Contact Lens Dry Eye Questionnaire (CLDEQ) during the study (20 symptomatic and 13 asymptomatic). The subjects were fitted with vifilcon A and senofilcon A lenses for a 2-week period, consecutively. Limbal hyperaemia (repeated measures analysis of variance; p < 0.05) and LWE (Friedman; p < 0.004) increased significantly during the study but not LIPCOF (p > or = 0.318; temporal, nasal, and Sum), bulbar hyperaemia (p = 0.432), staining (p > or = 0.060), OSDI (p = 0.126), or CLDEQ (p = 0.317, kappa = 0.279). Limbal hyperaemia significantly decreased in senofilcon A lenses. Wearing comfort among symptomatics was significantly better with senofilcon A (p = 0.005). At the enrolment visit, the subjects who became symptomatic exhibited significantly decreased NIBUT and increased LIPCOF and OSDI (range, p < 0.027). The best test combination to predict CLIDE (logistic regression analyses) was LIPCOF Sum plus NIBUT and OSDI, (positive predictive value = 87% and accuracy = 91%). LIPCOF, NIBUT, and OSDI are significant discriminators for CLIDE in new CL wearers compared with hyperaemia, tear meniscus height, phenol red thread test, staining, and LWE. The best test combination is NIBUT plus LIPCOF Sum and OSDI (named the Contact-Lens-Predicting-Test).
Short-term Effect of Scleral Lens on the Dry Eye Biomarkers in Keratoconus.
Carracedo, Gonzalo; Blanco, Maria Serramito; Martin-Gil, Alba; Zicheng, Wang; Alvarez, Jesús Carballo; Pintor, Jesús
2016-02-01
To evaluate the most important signs of dry eye, such as osmolarity, inflammation, and diadenosine tetraphosphate (Ap(4)A) concentration before and after wearing scleral lenses for 8 h in keratoconus patients. A pilot, experimental, short-term study involved 26 keratoconus patients (average age, 36.95 ± 8.95 years). They voluntarily enrolled in the study at the Optometry Clinic of the Faculty of Optics and Optometry in the University Complutense of Madrid. They were divided into two groups: patients with intrastromal corneal ring, the ICRS group, and patients without ICRS, the keratoconus (KC) group. Ocular Surface Disease Index questionnaire, the Schirmer test without anesthesia, tear break-up time, matrix metalloproteinase 9 (MMP-9) concentration, osmolarity, and Ap4A concentration were evaluated before and after wearing a scleral lens for 8 h. The patients wore the scleral lenses from 6 to 9 h, with a mean of 7.59 ± 0.73 h. The mean scleral lens sag for all patients was 4310 ± 166.31 μm, ranging from 4200 μm to 4800 μm. No significant changes in the Schirmer test and tear break-up time were found for either group. Ocular Surface Disease Index scores were statistically lower after wearing scleral lenses for both groups (p < 0.05). A significantly lower osmolarity and a significant rise of MMP-9 concentration after wearing scleral lenses were found in both groups (p < 0.05). Diadenosine tetraphosphate concentration was lower after wearing the scleral lens in the KC group (p < 0.05) but no significant difference was found for the ICRS group (p > 0.05). Short-term scleral lens wearing improves the symptomatology and some signs of dry eye, such as osmolarity and Ap4A concentration. The increase of MMP-9 concentration could be caused by tear film stagnation and use of preserved saline.
Design of ocular for optical sight with long exit pupil distance
NASA Astrophysics Data System (ADS)
Zhu, Zhongyao; Li, Yuyao; Tian, Ailing
2017-02-01
In order to solve the injury of optical sight to shooters, which is produced by recoil for using artillery or firearms, and the usage problems of shooters' eye mask, headband and gas mask, the ocular with long exit pupil distance has been designed based on optical sighting system. The optical properties and aberration characteristics of ocular with long exit pupil distance has been analyzed, the structural style with positive-positive-negative three lens groups has been put forward. According to the aberration theory and the isoplanatic image formation principle, the focal power assignment expression has been deduced by adopting analytical method. By using of optical design software ZEMAX, the ocular with long exit pupil distance has been designed, the focal length of system is 20mm, the exit pupil diameter is 4mm, the field angle is 40°, the distance of exit pupil is 41mm, and the relative eye relief is greater than 2. The design results show if this method has been adopted, the transfer functions of each field are all greater than 0.15 when the ocular with long exit pupil distance locates on 45lp/mm, which can meet the use requirements of visual optical instruments.
Simultaneous Bilateral Anterior and Posterior Lenticonus in Alport Syndrome.
Bamotra, Ravi Kant; Meenakshi; Kesarwani, Prem Chandra; Qayum, Shazia
2017-08-01
Alport syndrome is an inherited disease characterized by progressive renal failure, hearing loss, and ocular abnormalities like anterior lenticonus, corneal opacities, cataract, central perimacular and peripheral coalescing fleck retinopathies, and temporal retinal thinning. Although anterior lenticonus is common in Alport syndrome, simultaneous anterior and posterior lenticonus is a rare presentation. We report a case of a 22-year-old female with simultaneous anterior and posterior lenticonus presentation in which ocular examination lead to the detection of Alport syndrome. The patient had sensorineural deafness as well as microscopic haematuria. Clear lens extraction was performed in both eyes to eliminate lenticular irregular astigmatism for visual rehabilitation.
[Pay attention to the complexity of cataract surgery of no vitreous eyes].
Bao, Y Z
2017-04-11
With wide-spread performance of pars plana vitrectomy, cataract surgeries with no vitreous are getting more and more. This kind of surgery has great difference between individuals and it lacks randomized large sample clinical trial. Surgical strategy decision was basically relied on the surgeon's personal experience. We should fully aware the individual and common characteristics of no vitreous cataract surgery. Surgical time should be carefully decided. Complete ocular examination, evaluation, design of cataract surgical procedure and appropriate intra-ocular lens selection are needed. We must pay highly attention on the cataract surgery of no vitreous eyes. (Chin J Ophthalmol, 2017, 53: 241-243) .
Nagaraj, R H; Sell, D R; Prabhakaram, M; Ortwerth, B J; Monnier, V M
1991-01-01
Pentosidine is a recently discovered protein crosslink, involving lysine and arginine residues linked together in an imidazo [4,5,6] pyridinium ring formed by a 5-carbon sugar during nonenzymatic browning (Maillard reaction). The presence of high ascorbate levels in the human lens and its ability to undergo nonenzymatic browning led us to investigate pentosidine formation in the aging human lens. Incubation of lens crystallins with ascorbate and its oxidation products dehydroascorbate and 2,3-diketogulonate leads progressively to the formation of pentosidine crosslinks in the presence of oxygen. Under nitrogen, however, pentosidine forms only from 2,3-diketogulonate or xylosone, a degradation product of 2,3-diketogulonate. A high correlation between pentosidine crosslinks and the degree of lens pigmentation is noted in cataractous lenses. Pentosidine is found to be primarily associated with alpha-crystallin fractions of 300-5000 kDa. These results suggest that redox imbalance in cellular senescent systems such as the ocular lens may lead to irreversible ascorbate oxidation and protein crosslinking by xylosone. This mechanism may play an important role in the pathogenesis of "brunescent" cataracts. Images PMID:1946446
Risk factors for microbial keratitis with contemporary contact lenses: a case-control study.
Dart, J K G; Radford, C F; Minassian, D; Verma, S; Stapleton, F
2008-10-01
To assess the relative risks (RR) of microbial keratitis (MK) for contemporary contact lens (CL) types and wearing schedules. A 2-year prospective case-control study begun in December 2003. Cases were 367 CL wearers attending Moorfields Eye Hospital with proven or presumed MK. Controls were 1069 hospital controls, who were CL wearers with a disorder unrelated to CL wear, and 639 population-based controls who were CL wearers randomly selected from the Moorfields catchment area. Hospital patients completed a self-administered questionnaire; population-based controls were interviewed by telephone. Multivariate analysis was done both for all cases of MK, and for the moderate and severe MK subgroups alone. The RR for developing MK, and vision loss, for all lens types compared with planned replacement soft lenses (the referent). Compared with planned replacement soft lenses (the referent), the RR of MK was significantly increased with daily disposable (DD) CLs (RR, 1.56x [95% confidence interval (CI), 1.1-2.1]; P = 0.009) and differed between different brands of DD lens, was reduced for rigid lenses (RR, 0.16x [95% CI, 0.06-0.4]; P<0.001), and no different for silicone hydrogel or other types of soft lens. Although the risk of MK was higher overall among DD lens users, the risk of vision loss was less than for planned replacement soft CL users (P = 0.05); no DD lens users lost vision to the level of >or=20/40. The RR for overnight wear, for any lens type, was 5.4 times higher (95% CI, 3.3-10.9; P<0.001). Comparison of the DD soft CL types with planned replacement soft lenses (the referent), showed significant differences between brands for the risk of MK. The risk of MK has not been reduced in users of DD and silicone hydrogel CLs. However, vision loss is less likely to occur in DD than in reusable soft CL users. Different brands of CL may be associated with significantly different risks of keratitis; understanding these differences should lead to the development of safer soft lenses. These findings suggest that lens/ocular surface interactions may be more important in the development of corneal infection than oxygen levels and CL case contamination.
The clinical and cellular basis of contact lens-related corneal infections
Robertson, Danielle M; Cavanagh, H Dwight
2008-01-01
Microbial keratitis (MK) is the most visually devastating complication associated with contact lens wear. Pseudomonas aeruginosa (PA) is highly invasive in the corneal epithelium and is responsible for more than half of the reported cases of contact lens-related MK. To protect against Pseudomonas-mediated MK, the corneal epithelium has evolved overlapping defense mechanisms that function to protect the ocular surface from microbial invasion. Research has shown that contact lens wear disrupts these protective mechanisms through breakdown of normal homeostatic surface renewal as well as damaging the corneal surface, exposing underlying cell membrane receptors that bind and internalize PA through the formation of lipid rafts. Human clinical trials have shown that initial adherence of PA with resulting increased risk for microbial infection is mediated in part by contact lens oxygen transmissibility. Recently, chemical preserved multipurpose solutions (MPS) have been implicated in increasing PA adherence to corneal epithelial cells, in addition to inducing significant levels of toxic staining when used in conjunction with specific silicone hydrogel lenses. This review summarizes what is currently known about the relationship between contact lenses, the corneal epithelium, MPS, and infection. PMID:19277209
NASA Astrophysics Data System (ADS)
Yang, Que; Wang, Shanshan; Wang, Kai; Zhang, Chunyu; Zhang, Lu; Meng, Qingyu; Zhu, Qiudong
2015-08-01
For normal eyes without history of any ocular surgery, traditional equations for calculating intraocular lens (IOL) power, such as SRK-T, Holladay, Higis, SRK-II, et al., all were relativley accurate. However, for eyes underwent refractive surgeries, such as LASIK, or eyes diagnosed as keratoconus, these equations may cause significant postoperative refractive error, which may cause poor satisfaction after cataract surgery. Although some methods have been carried out to solve this problem, such as Hagis-L equation[1], or using preoperative data (data before LASIK) to estimate K value[2], no precise equations were available for these eyes. Here, we introduced a novel intraocular lens power estimation method by accurate ray tracing with optical design software ZEMAX. Instead of using traditional regression formula, we adopted the exact measured corneal elevation distribution, central corneal thickness, anterior chamber depth, axial length, and estimated effective lens plane as the input parameters. The calculation of intraocular lens power for a patient with keratoconus and another LASIK postoperative patient met very well with their visual capacity after cataract surgery.
Low-Dose Radiation Cataract and Genetic Determinants of Radiosensitivity
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kleiman, Norman Jay
The lens of the eye is one of the most radiosensitive tissues in the body. Ocular ionizing radiation exposure results in characteristic, dose related, progressive lens changes leading to cataract formation. While initial, early stages of lens opacification may not cause visual disability, the severity of such changes progressively increases with dose until vision is impaired and cataract extraction surgery may be required. Because of the transparency of the eye, radiation induced lens changes can easily be followed non-invasively over time. Thus, the lens provides a unique model system in which to study the effects of low dose ionizing radiationmore » exposure in a complex, highly organized tissue. Despite this observation, considerable uncertainties remain surrounding the relationship between dose and risk of developing radiation cataract. For example, a growing number of human epidemiological findings suggest significant risk among various groups of occupationally and accidentally exposed individuals and confidence intervals that include zero dose. Nevertheless, questions remain concerning the relationship between lens opacities, visual disability, clinical cataract, threshold dose and/or the role of genetics in determining radiosensitivity. Experimentally, the response of the rodent eye to radiation is quite similar to that in humans and thus animal studies are well suited to examine the relationship between radiation exposure, genetic determinants of radiosensitivity and cataractogenesis. The current work has expanded our knowledge of the low-dose effects of X-irradiation or high-LET heavy ion exposure on timing and progression of radiation cataract and has provided new information on the genetic, molecular, biochemical and cell biological features which contribute to this pathology. Furthermore, findings have indicated that single and/or multiple haploinsufficiency for various genes involved in DNA repair and cell cycle checkpoint control, such as Atm, Brca1 or Rad9, influence cataract development and thus radiosensitivity. These observations have direct applicability to various human populations including accidentally exposed individuals, interventional medical workers, astronauts and nuclear plant workers.« less
Why Does the Healthy Cornea Resist Pseudomonas aeruginosa Infection?
Evans, David J.; Fleiszig, Suzanne M. J.
2013-01-01
Purpose To provide our perspective on why the cornea is resistant to infection based on our research results with Pseudomonas aeruginosa. Perspective We focus on our current understanding of the interplay between bacteria, tear fluid and the corneal epithelium that determine health as the usual outcome, and propose a theoretical model for how contact lens wear might change those interactions to enable susceptibility to P. aeruginosa infection. Methods Use of “null-infection” in vivo models, cultured human corneal epithelial cells, contact lens-wearing animal models, and bacterial genetics help to elucidate mechanisms by which P. aeruginosa survive at the ocular surface, adheres, and traverses multilayered corneal epithelia. These models also help elucidate the molecular mechanisms of corneal epithelial innate defense. Results and Discussion Tear fluid and the corneal epithelium combine to make a formidable defense against P. aeruginosa infection of the cornea. Part of that defense involves the expression of antimicrobials such as β-defensins, the cathelicidin LL-37, cytokeratin-derived antimicrobial peptides, and RNase7. Immunomodulators such as SP-D and ST2 also contribute. Innate defenses of the cornea depend in part on MyD88, a key adaptor protein of TLR and IL-1R signaling, but the basal lamina represents the final barrier to bacterial penetration. Overcoming these defenses involves P. aeruginosa adaptation, expression of the type three secretion system, proteases, and P. aeruginosa biofilm formation on contact lenses. Conclusion After more than two decades of research focused on understanding how contact lens wear predisposes to P. aeruginosa infection, our working hypothesis places blame for microbial keratitis on bacterial adaptation to ocular surface defenses, combined with changes to the biochemistry of the corneal surface caused by trapping bacteria and tear fluid against the cornea under the lens. PMID:23601656
Biocompatibility of antimicrobial melimine lenses: rabbit and human studies.
Dutta, Debarun; Ozkan, Jerome; Willcox, Mark D P
2014-05-01
Covalent immobilization of antimicrobial peptide melimine onto contact lenses can produce broad-spectrum antimicrobial lenses. The purpose of this study was to investigate the performance of melimine-coated contact lenses in an animal model and human clinical trial. Melimine was covalently attached onto the surface of contact lenses via EDC (1-ethyl-3-[3-dimethylaminopropyl] carbodiimide hydrochloride) coupling. A rabbit model of daily contralateral wear of lenses for 22 days was conducted to assess the lens safety. A prospective, randomized, double-masked, one-day human clinical trial was used to evaluate subjective responses and ocular physiology during contralateral wear of melimine-coated (test) and uncoated (control) lenses. Delayed reactions were monitored during follow-up visits after 1 and 4 weeks. Ex vivo retention of antimicrobial activity of worn lenses was assessed by reduction in numbers of viable Pseudomonas aeruginosa and Staphylococcus aureus. Melimine-coated lenses produced no ocular signs or symptoms that would indicate cytotoxicity during the lens wear of rabbits. No histological changes were found in rabbit corneas. During the human trial, no differences were observed in wettability, surface deposition, lens-fitting centration, movement, tightness, and corneal coverage between test and control lenses (p > 0.05). There were no significant differences in bulbar, limbal, or palpebral redness or conjunctival staining (p > 0.05). Mean corneal (extent, depth, and type) staining was higher for test lenses compared with that for control lenses (p < 0.05). There was no significant difference in subjective responses for lens comfort, dryness, and awareness (p > 0.05). No delayed reactions were associated with the test lenses. Worn test lenses retained more than 1.5 log inhibition against both bacterial types. Melimine-coated contact lenses were worn safely by humans. However, they were associated with higher corneal staining. The melimine-coated lenses retained high antibacterial activity after wear.
Optical Assessment of Soft Contact Lens Edge-Thickness.
Tankam, Patrice; Won, Jungeun; Canavesi, Cristina; Cox, Ian; Rolland, Jannick P
2016-08-01
To assess the edge shape of soft contact lenses using Gabor-Domain Optical Coherence Microscopy (GD-OCM) with a 2-μm imaging resolution in three dimensions and to generate edge-thickness profiles at different distances from the edge tip of soft contact lenses. A high-speed custom-designed GD-OCM system was used to produce 3D images of the edge of an experimental soft contact lens (Bausch + Lomb, Rochester, NY) in four different configurations: in air, submerged into water, submerged into saline with contrast agent, and placed onto the cornea of a porcine eyeball. An algorithm to compute the edge-thickness was developed and applied to cross-sectional images. The proposed algorithm includes the accurate detection of the interfaces between the lens and the environment, and the correction of the refraction error. The sharply defined edge tip of a soft contact lens was visualized in 3D. Results showed precise thickness measurement of the contact lens edge profile. Fifty cross-sectional image frames for each configuration were used to test the robustness of the algorithm in evaluating the edge-thickness at any distance from the edge tip. The precision of the measurements was less than 0.2 μm. The results confirmed the ability of GD-OCM to provide high-definition images of soft contact lens edges. As a nondestructive, precise, and fast metrology tool for soft contact lens measurement, the integration of GD-OCM in the design and manufacturing of contact lenses will be beneficial for further improvement in edge design and quality control. In the clinical perspective, the in vivo evaluation of the lens fitted onto the cornea will advance our understanding of how the edge interacts with the ocular surface. The latter will provide insights into the impact of long-term use of contact lenses on the visual performance.
Optical Assessment of Soft Contact Lens Edge-Thickness
Tankam, Patrice; Won, Jungeun; Canavesi, Cristina; Cox, Ian; Rolland, Jannick P.
2016-01-01
Purpose To assess the edge shape of soft contact lenses using Gabor-Domain Optical Coherence Microscopy (GD-OCM) with a 2 μm imaging resolution in three dimensions, and to generate edge-thickness profiles at different distances from the edge tip of soft contact lenses. Methods A high-speed custom-designed GD-OCM system was used to produce 3D images of the edge of an experimental soft contact lens (Bausch + Lomb, Rochester NY) in four different configurations: in air, submerged into water, submerged into saline with contrast agent, and placed onto the cornea of a porcine eyeball. An algorithm to compute the edge-thickness was developed and applied to cross-sectional images. The proposed algorithm includes the accurate detection of the interfaces between the lens and the environment, and the correction of the refraction error. Results The sharply defined edge tip of a soft contact lens was visualized in 3D. Results showed precise thickness measurement of the contact lens edge profile. 50 cross-sectional image frames for each configuration were used to test the robustness of the algorithm in evaluating the edge-thickness at any distance from the edge tip. The precision of the measurements was less than 0.2 μm. Conclusions The results confirmed the ability of GD-OCM to provide high definition images of soft contact lens edges. As a non-destructive, precise, and fast metrology tool for soft contact lens measurement, the integration of GD-OCM in the design and manufacturing of contact lenses will be beneficial for further improvement in edge design and quality control. In the clinical perspective, the in-vivo evaluation of the lens fitted onto the cornea will advance our understanding of how the edge interacts with the ocular surface. The latter will provide insights into the impact of long-term use of contact lenses on the visual performance. PMID:27232902
Chauss, Daniel; Brennan, Lisa A.; Bakina, Olga; Kantorow, Marc
2015-01-01
Accumulation of apoptotic material is toxic and associated with cataract and other disease states. Identification of mechanisms that prevent accumulation of apoptotic debris is important for establishing the etiology of these diseases. The ocular lens is routinely assaulted by UV light that causes lens cell apoptosis and is associated with cataract formation. To date, no molecular mechanism for removal of toxic apoptotic debris has been identified in the lens. Vesicular debris within lens cells exposed to UV light has been observed raising speculation that lens cells themselves could act as phagocytes to remove toxic apoptotic debris. However, phagocytosis has not been confirmed as a function of the intact eye lens, and no mechanism for lens phagocytosis has been established. Here, we demonstrate that the eye lens is capable of phagocytizing extracellular lens cell debris. Using high throughput RNA sequencing and bioinformatics analysis, we establish that lens epithelial cells express members of the integrin αVβ5-mediated phagocytosis pathway and that internalized cell debris co-localizes with αVβ5 and with RAB7 and Rab-interacting lysosomal protein that are required for phagosome maturation and fusion with lysosomes. We demonstrate that the αVβ5 receptor is required for lens epithelial cell phagocytosis and that UV light treatment of lens epithelial cells results in damage to the αVβ5 receptor with concomitant loss of phagocytosis. These data suggest that loss of αVβ5-mediated phagocytosis by the eye lens could result in accumulation of toxic cell debris that could contribute to UV light-induced cataract formation. PMID:26527683
Sapkota, Kishor; Franco, Sandra; Lira, Madalena
2018-06-01
To investigate the effect of soft contact lenses (SCL) wearing modality and lens materials on the changes in conjunctival bulbar and limbal redness and conjunctival and corneal staining after two months of SCL wear. Comfort level was also analyzed. In this longitudinal clinical trial, forty-seven neophyte myopic subjects were fitted with a monthly disposable lens (lotrafilcon-B or comfilcon-A or balafilcon-A) in one eye and a daily disposable lens (nelfilcon-A or stenofilcon-A or nesofilcon-A) in the other eye, randomly selected. Conjunctival bulbar and limbal redness and conjunctival and corneal staining were evaluated before and after lens wear. Effect of lens wearing modality and lens materials on these changes was also determined. Level of comfort was evaluated subjectively twice per day. Comfort level and reduction in end-of-day comfort were compared between different lens wearing modalities and materials. Bulbar and limbal redness and conjunctival and corneal staining were increased (p<0.001) after lens wear, and changes were similar with daily and monthly disposable lens wear (p>0.05). Limbal redness was associated with lens materials, and lotrafilcon-B induced the least among the studied lenses (p<0.05). There was no significant association between the wearing modality and the average comfort level and reduction of end-of-day comfort (p>0.05). Two months of SCL wear increased conjunctival redness, conjunctival and corneal staining, which were not associated with the lens wearing modality. There was a reduction in end-of-day comfort, similar to daily and monthly lenses. The change in limbal redness and reduction in end-of-day comfort were associated with the characteristics of the lens material. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
Transcription, Translation, and Function of Lubricin, a Boundary Lubricant, at the Ocular Surface
Schmidt, Tannin A.; Sullivan, David A.; Knop, Erich; Richards, Stephen M.; Knop, Nadja; Liu, Shaohui; Sahin, Afsun; Darabad, Raheleh Rahimi; Morrison, Sheila; Kam, Wendy R.; Sullivan, Benjamin D.
2013-01-01
Importance Lubricin may be an important barrier to the development of corneal and conjunctival epitheliopathies that may occur in dry eye disease and contact lens wear. Objective To test the hypotheses that lubricin (ie, proteoglycan 4 [PRG4]), a boundary lubricant, is produced by ocular surface epithelia and acts to protect the cornea and conjunctiva against significant shear forces generated during an eyelid blink and that lubricin deficiency increases shear stress on the ocular surface and promotes corneal damage. Design, Setting, and Participants Human, porcine, and mouse tissues and cells were processed for molecular biological, immunohistochemical, and tribological studies, and wild-type and PRG4 knockout mice were evaluated for corneal damage. Results Our findings demonstrate that lubricin is transcribed and translated by corneal and conjunctival epithelial cells. Lubricin messenger RNA is also present in lacrimal and meibomian glands, as well as in a number of other tissues. Absence of lubricin in PRG4 knockout mice is associated with a significant increase in corneal fluorescein staining. Our studies also show that lubricin functions as an effective friction-lowering boundary lubricant at the human cornea-eyelid interface. This effect is specific and cannot be duplicated by the use of hyaluronate or bovine serum albumin solutions. Conclusions and Relevance Our results show that lubricin is transcribed, translated, and expressed by ocular surface epithelia. Moreover, our findings demonstrate that lubricin presence significantly reduces friction between the cornea and conjunctiva and that lubricin deficiency may play a role in promoting corneal damage. PMID:23599181
Transcription, translation, and function of lubricin, a boundary lubricant, at the ocular surface.
Schmidt, Tannin A; Sullivan, David A; Knop, Erich; Richards, Stephen M; Knop, Nadja; Liu, Shaohui; Sahin, Afsun; Darabad, Raheleh Rahimi; Morrison, Sheila; Kam, Wendy R; Sullivan, Benjamin D
2013-06-01
Lubricin may be an important barrier to the development of corneal and conjunctival epitheliopathies that may occur in dry eye disease and contact lens wear. To test the hypotheses that lubricin (ie, proteoglycan 4 [PRG4 ]), a boundary lubricant, is produced by ocular surface epithelia and acts to protect the cornea and conjunctiva against significant shear forces generated during an eyelid blink and that lubricin deficiency increases shear stress on the ocular surface and promotes corneal damage. Human, porcine, and mouse tissues and cells were processed for molecular biological, immunohistochemical, and tribological studies, and wild-type and PRG4 knockout mice were evaluated for corneal damage. Our findings demonstrate that lubricin is transcribed and translated by corneal and conjunctival epithelial cells. Lubricin messenger RNA is also present in lacrimal and meibomian glands, as well as in a number of other tissues. Absence of lubricin in PRG4 knockout mice is associated with a significant increase in corneal fluorescein staining. Our studies also show that lubricin functions as an effective friction-lowering boundary lubricant at the human cornea-eyelid interface. This effect is specific and cannot be duplicated by the use of hyaluronate or bovine serum albumin solutions. Our results show that lubricin is transcribed, translated, and expressed by ocular surface epithelia. Moreover, our findings demonstrate that lubricin presence significantly reduces friction between the cornea and conjunctiva and that lubricin deficiency may play a role in promoting corneal damage.
Ocular inflammatory effects of intravitreally-injected tumor necrosis factor.
Rosenbaum, J. T.; Howes, E. L.; Rubin, R. M.; Samples, J. R.
1988-01-01
Many of the pathophysiologic effects of bacterial endotoxin have recently been attributed to a monokine, tumor necrosis factor (TNF). The rabbit eye is extremely sensitive to locally injected endotoxin. The authors have investigated the possible contribution of TNF to ocular inflammation in a rabbit model. The intravitreal injection of 10(5) to 5 X 10(5) units of recombinant human TNF produced a sustained disruption of the blood-aqueous barrier as manifested by elevated aqueous humor protein levels. In addition, 83% of rabbits receiving this dose of TNF developed hyperemia of limbal vessels and early neovascularization of the cornea. Many developed posterior synechiae (fibrous adhesions between the iris and the lens). TNF induced only a slight cellular response in the anterior chamber. Histologic studies confirmed the presence of new vessels and demonstrated a marked mononuclear infiltrate within and beneath the epithelium of the iris and ciliary body. Lower doses of TNF produced inconsistent results. Heating TNF completely destroyed its inflammatory effects. The time course of the ocular response to TNF and the quantity of recombinant protein needed to produce consistent effects were vastly different from effects observed with interleukin-1. For example, 24 hours after an intravitreal injection, 2.2 X 10(4) ng of TNF (5 X 10(5) units) produced significantly less protein extravasation and polymorphonuclear leukocyte infiltration than 4 ng of recombinant interleukin-1. Similarly, 24 hours after intravitreal injection, 1 ng of Escherichia coli endotoxin tended to be a more potent inflammatory stimulus than this quantity of TNF. These observations indicate that the ocular pathophysiologic effects of TNF can be readily distinguished from changes induced by either endotoxin or another endotoxin induced monokine, interleukin-1. Images Figure 1 Figure 2 Figure 3 Figure 4 PMID:3263050
Yavuz, Burçin; Bozdağ Pehlivan, Sibel; Kaffashi, Abbas; Çalamak, Semih; Ulubayram, Kezban; Palaska, Erhan; Çakmak, Hasan Basri; Ünlü, Nurşen
2016-11-01
Biodegradable implants are promising drug delivery systems for sustained release ocular drug delivery with the benefits such as minimum systemic side effects, constant drug concentration at the target site and getting cleared without surgical removal. Dry eye syndrome (DES) is a common disease characterized with the changes in ocular epithelia surface and results in inflammatory reaction that might lead to blindness. Cyclosporin A (CsA) is a cyclic peptide that is frequently employed for the treatment of DES and it needs to be applied several times a day in tear drops form. The aim of this study was to evaluate in vivo behavior and efficacy of the developed nano-decorated subconjunctival implant systems for sustained release CsA delivery. Biodegradable Poly-ɛ-caprolactone (PCL) implant or micro-fiber implants containing CsA loaded poly-lactide-co-glycolide (85:15) (PLGA) or PCL nanoparticles were prepared in order to achieve sustained release. Two of the formulations PCL-PLGA-NP-F and PCL-PCL-NP-I were selected for in vivo evaluation based on their in vitro characteristics determined in our previous study. In this study, formulations were implanted to Swiss Albino mice with induced dry eye syndrome to investigate the ocular distribution of CsA following subconjunctival implantation and to evaluate the efficacy. Tissue distribution study indicated that CsA was present in ocular tissues such as cornea, sclera and lens even 90 days after the application and blood CsA levels were found lower than ocular tissues. Efficacy studies also showed that application of CsA-loaded fiber implant formulation resulted in faster recovery based on their staining scores.
Crystalline lens thickness determines the perceived chromatic difference in magnification.
Chen, Yun; Schaeffel, Frank
2014-03-01
Since the origin of the high interindividual variability of the chromatic difference in retinal image magnification (CDM) in the human eye is not well understood, optical parameters that might determine its magnitude were studied in 21 healthy subjects with ages ranging from 21 to 58 years. Two psychophysical procedures were used to quantify CDM. They produced highly correlated results. First, a red and a blue square, presented on a black screen, had to be matched in size by the subjects with their right eyes. Second, a filled red and blue square, flickering on top of each other at 2 Hz, had to be adjusted in perceived brightness and then in size to minimize the impression of flicker. CDM varied widely among subjects from 0.0% to 3.6%. Biometric ocular parameters were measured with low coherence interferometry and crystalline lens tilt and decentration with a custom-built Purkinjemeter. Correlations were studied between CDM and corneal power, anterior chamber depth, lens thickness, lens tilt and lens decentration, and vitreous chamber depths. Lens thickness was found significantly correlated with CDM and accounted for 64% of its variance. Vertical lens tilt and decentration were also significantly correlated. It was also found that CDM increased by 3.5% per year, and part of this change can be attributed to the age-related increase in lens thickness.
Predicting through-focus visual acuity with the eye's natural aberrations.
Kingston, Amanda C; Cox, Ian G
2013-10-01
To develop a predictive optical modeling process that utilizes individual computer eye models along with a novel through-focus image quality metric. Individual eye models were implemented in optical design software (Zemax, Bellevue, WA) based on evaluation of ocular aberrations, pupil diameter, visual acuity, and accommodative response of 90 subjects (180 eyes; 24-63 years of age). Monocular high-contrast minimum angle of resolution (logMAR) acuity was assessed at 6 m, 2 m, 1 m, 67 cm, 50 cm, 40 cm, 33 cm, 28 cm, and 25 cm. While the subject fixated on the lowest readable line of acuity, total ocular aberrations and pupil diameter were measured three times each using the Complete Ophthalmic Analysis System (COAS HD VR) at each distance. A subset of 64 mature presbyopic eyes was used to predict the clinical logMAR acuity performance of five novel multifocal contact lens designs. To validate predictability of the design process, designs were manufactured and tested clinically on a population of 24 mature presbyopes (having at least +1.50 D spectacle add at 40 cm). Seven object distances were used in the validation study (6 m, 2 m, 1 m, 67 cm, 50 cm, 40 cm, and 25 cm) to measure monocular high-contrast logMAR acuity. Baseline clinical through-focus logMAR was shown to correlate highly (R² = 0.85) with predicted logMAR from individual eye models. At all object distances, each of the five multifocal lenses showed less than one line difference, on average, between predicted and clinical normalized logMAR acuity. Correlation showed R² between 0.90 and 0.97 for all multifocal designs. Computer-based models that account for patient's aberrations, pupil diameter changes, and accommodative amplitude can be used to predict the performance of contact lens designs. With this high correlation (R² ≥ 0.90) and high level of predictability, more design options can be explored in the computer to optimize performance before a lens is manufactured and tested clinically.
Nickla, D L; Wildsoet, C; Wallman, J
1997-04-01
It has been demonstrated that chick eye growth compensates for defocus imposed by spectacle lenses: the eye elongates in response to hyperopic defocus imposed by negative lenses and slows its elongation in response to myopic defocus imposed by positive lenses. We ask whether the synthesis of scleral extracellular matrix, specifically glycosaminoglycans, changes in parallel with the changes in ocular elongation. In addition, there is a choroidal component to compensation for spectacle lenses; the choroid thickens in response to myopic defocus and thins in response to hyperopic defocus. We ask whether choroidal glycosaminoglycan synthesis changes in parallel with changes in choroidal thickness. Chicks wore either a +15 diopter (D) or -15 D spectacle lens over one eye, or they wore one lens of each power over each eye for 5 days. At the end of this period, we measured refractive errors and ocular dimensions by refractometry and A-scan ultrasonography, respectively. Pieces of the scleras and choroids from these eyes were put into culture and the synthesis of glycosaminoglycans was assessed by measuring the incorporation of radioactive inorganic sulfur. We here report that the compensatory modulation of the length of the eye involves changes in the synthesis of glycosaminoglycans in the sclera, with synthesis increasing in eyes wearing -15 D spectacles lenses and decreasing in eyes wearing +15 D lenses. In addition, changes in the synthesis of glycosaminoglycans in the choroid are correlated with changes in choroidal thickness: eyes wearing +15 D lenses develop thicker choroids and these choroids synthesize more glycosaminoglycans than choroids from eyes wearing -15 D lenses. Changes in scleral glycosaminoglycan synthesis accompany lens-induced changes in the length of the eye. Furthermore, changes in the thickness of the choroid are also associated with changes in the synthesis of glycosaminoglycans. These results are consistent with the regulation of the growth of the eye being bidirectional, and with the retina being able to sense the sign of defocus.
The effects of iris-ciliary complex on the organ cultured rabbit ocular lens.
Niyogi, T K; Emanuel, K; Parafina, J; Bagchi, M
1991-01-01
Freshly isolated rabbit lenses were cultured with and without attached iris-ciliary (IC)-complex for 24 hours in TC-199 medium. Subsequent morphological analysis revealed that the IC-complex cannot be maintained in serum-free medium. In addition an observed effect of the IC-complex on the co-cultured lenses could not be due only because of the cellular degeneration of the IC-complex. To test this possibility lenses with attached IC-complexes were incubated in 20% serum-containing TC-199 medium. The IC-complex cultured in 20% serum containing medium retained its normal morphology. However co-cultured lens cells displayed vacuoles and other signs of degeneration. The protein synthetic and Na+/K+ pump activities of these lenses were also significantly depressed. These data indicated that the observed effects of IC-complex on the lens were not due to its cellular degradation. Preliminary experiments showed that the IC-complex contains water soluble factor(s) which could effectively inhibit lens protein synthesis and Na+/K+ pump.
Estimating a just-noticeable difference for ocular comfort in contact lens wearers.
Papas, Eric B; Keay, Lisa; Golebiowski, Blanka
2011-06-21
To estimate the just-noticeable difference (JND) in ocular comfort rating by human, contact lens-wearing subjects using 1 to 100 numerical scales. Ostensibly identical, new contact lenses were worn simultaneously in both eyes by 40 subjects who made individual comfort ratings for each eye using a 100-point numerical ratings scale (NRS). Concurrently, interocular preference was indicated on a five-point Likert scale (1 to 5: strongly prefer right, slightly prefer right, no preference, slightly prefer left, strongly prefer left, respectively). Differences in NRS comfort score (ΔC) between the right and left eyes were determined for each Likert scale preference criteria. The distribution of group ΔC scores was examined relative to alternative definitions of JND as a means of estimating its value. For Likert scores indicating the presence of a slight interocular preference, absolute ΔC ranged from 1 to 30 units with a mean of 7.4 ± 1.3 (95% confidence interval) across all lenses and trials. When there was no Likert scale preference expressed between the eyes, absolute ΔC did not exceed 5 units. For ratings of comfort using a 100-point numerical rating scale, the inter-ocular JND is unlikely to be less than 5 units. The estimate for the average value in the population was approximately 7 to 8 units. These numbers indicate the lowest level at which changes in comfort measured with such scales are likely to be clinically significant.
Olfactomedin-like 2 A and B (OLFML2A and OLFML2B) expression profile in primates (human and baboon).
Pérez-Ibave, Diana Cristina; González-Alvarez, Rafael; de La Luz Martinez-Fierro, Margarita; Ruiz-Ayma, Gabriel; Luna-Muñoz, Maricela; Martínez-De-Villarreal, Laura Elia; De Lourdes Garza-Rodríguez, María; Reséndez-Pérez, Diana; Mohamed-Noriega, Jibran; Garza-Guajardo, Raquel; Bautista-De-Lucío, Víctor Manuel; Mohamed-Noriega, Karim; Barboza-Quintana, Oralia; Arámburo-De-La-Hoz, Carlos; Barrera-Saldaña, Hugo Alberto; Rodríguez-Sánchez, Irám Pablo
2016-11-08
The olfactomedin-like domain (OLFML) is present in at least four families of proteins, including OLFML2A and OLFML2B, which are expressed in adult rat retina cells. However, no expression of their orthologous has ever been reported in human and baboon. The aim of this study was to investigate the expression of OLFML2A and OLFML2B in ocular tissues of baboons (Papio hamadryas) and humans, as a key to elucidate OLFML function in eye physiology. OLFML2A and OLFML2B cDNA detection in ocular tissues of these species was performed by RT-PCR. The amplicons were cloned and sequenced, phylogenetically analyzed and their proteins products were confirmed by immunofluorescence assays. OLFML2A and OLFML2B transcripts were found in human cornea, lens and retina and in baboon cornea, lens, iris and retina. The baboon OLFML2A and OLFML2B ORF sequences have 96% similarity with their human's orthologous. OLFML2A and OLFML2B evolution fits the hypothesis of purifying selection. Phylogenetic analysis shows clear orthology in OLFML2A genes, while OLFML2B orthology is not clear. Expression of OLFML2A and OLFML2B in human and baboon ocular tissues, including their high similarity, make the baboon a powerful model to deduce the physiological and/or metabolic function of these proteins in the eye.
Digital-holographic analysis of femtosecond laser-induced photodisruption in ocular tissue
NASA Astrophysics Data System (ADS)
Saerchen, Emanuel; Biessy, Kevin; Kemper, Björn; Lubatschowski, Holger
2014-02-01
High repetition rated femtosecond laser oscillator systems with low pulse energy are more often applied for precise and safer eye surgery. Especially, the cutting procedure in the crystalline lens is of high important for presbyopia treatment. Nevertheless, the fundamental laser tissue interaction process is not completely understood, because apparently a self-induced process takes place, were one modified region changes the focusing behavior of following laser pulses. We used a MHz repetition rate femtosecond laser system with nJ-pulse energy which were focused inside an ocular-tissue-phantom (Hydroxy-ethylmethacrylat - HEMA) to induce photodisruption. The material change, caused by the fs-pulses was measured simultaneously with a compact digital-holographic microscope. To investigate the material manipulation at different time scales, we used a continuously illuminating light source. The holographic images provide quantitative values for optical path length difference (OPL), which is equivalent to a refractive index change. This change of the optical properties may cause following pulses to obtain different focusing conditions. Time lapse measurements during the laser application were performed, which show the temporal evolution of OPL. An increase of OPL during the laser application was measured, which was followed by a decrease in OPL after laser processing. Furthermore, similar experiments were performed in distilled water and in native porcine crystalline lenses. The fs-laser cutting effects in HEMA and crystalline lens were transferable. Simultaneous measurements of the material modification during the cutting process give rise to better knowledge of treatment modalities during ocular tissue processing.
Crystalline lens power and refractive error.
Iribarren, Rafael; Morgan, Ian G; Nangia, Vinay; Jonas, Jost B
2012-02-01
To study the relationships between the refractive power of the crystalline lens, overall refractive error of the eye, and degree of nuclear cataract. All phakic participants of the population-based Central India Eye and Medical Study with an age of 50+ years were included. Calculation of the refractive lens power was based on distance noncycloplegic refractive error, corneal refractive power, anterior chamber depth, lens thickness, and axial length according to Bennett's formula. The study included 1885 subjects. Mean refractive lens power was 25.5 ± 3.0 D (range, 13.9-36.6). After adjustment for age and sex, the standardized correlation coefficients (β) of the association with the ocular refractive error were highest for crystalline lens power (β = -0.41; P < 0.001) and nuclear lens opacity grade (β = -0.42; P < 0.001), followed by axial length (β = -0.35; P < 0.001). They were lowest for corneal refractive power (β = -0.08; P = 0.001) and anterior chamber depth (β = -0.05; P = 0.04). In multivariate analysis, refractive error was significantly (P < 0.001) associated with shorter axial length (β = -1.26), lower refractive lens power (β = -0.95), lower corneal refractive power (β = -0.76), higher lens thickness (β = 0.30), deeper anterior chamber (β = 0.28), and less marked nuclear lens opacity (β = -0.05). Lens thickness was significantly lower in eyes with greater nuclear opacity. Variations in refractive error in adults aged 50+ years were mostly influenced by variations in axial length and in crystalline lens refractive power, followed by variations in corneal refractive power, and, to a minor degree, by variations in lens thickness and anterior chamber depth.
Ramasubramanian, Viswanathan; Glasser, Adrian
2015-01-01
PURPOSE To determine whether relatively low-resolution ultrasound biomicroscopy (UBM) can predict the accommodative optical response in prepresbyopic eyes as well as in a previous study of young phakic subjects, despite lower accommodative amplitudes. SETTING College of Optometry, University of Houston, Houston, USA. DESIGN Observational cross-sectional study. METHODS Static accommodative optical response was measured with infrared photorefraction and an autorefractor (WR-5100K) in subjects aged 36 to 46 years. A 35 MHz UBM device (Vumax, Sonomed Escalon) was used to image the left eye, while the right eye viewed accommodative stimuli. Custom-developed Matlab image-analysis software was used to perform automated analysis of UBM images to measure the ocular biometry parameters. The accommodative optical response was predicted from biometry parameters using linear regression, 95% confidence intervals (CIs), and 95% prediction intervals. RESULTS The study evaluated 25 subjects. Per-diopter (D) accommodative changes in anterior chamber depth (ACD), lens thickness, anterior and posterior lens radii of curvature, and anterior segment length were similar to previous values from young subjects. The standard deviations (SDs) of accommodative optical response predicted from linear regressions for UBM-measured biometry parameters were ACD, 0.15 D; lens thickness, 0.25 D; anterior lens radii of curvature, 0.09 D; posterior lens radii of curvature, 0.37 D; and anterior segment length, 0.42 D. CONCLUSIONS Ultrasound biomicroscopy parameters can, on average, predict accommodative optical response with SDs of less than 0.55 D using linear regressions and 95% CIs. Ultrasound biomicroscopy can be used to visualize and quantify accommodative biometric changes and predict accommodative optical response in prepresbyopic eyes. PMID:26049831
Vision-guided ocular growth in a mutant chicken model with diminished visual acuity
Ritchey, Eric R.; Zelinka, Christopher; Tang, Junhua; Liu, Jun; Code, Kimberly A.; Petersen-Jones, Simon; Fischer, Andy J.
2012-01-01
Visual experience is known to guide ocular growth. We tested the hypothesis that vision-guided ocular growth is disrupted in a model system with diminished visual acuity. We examine whether ocular elongation is influenced by form-deprivation (FD) and lens-imposed defocus in the Retinopathy, Globe Enlarged (RGE) chicken. Young RGE chicks have poor visual acuity, without significant retinal pathology, resulting from a mutation in guanine nucleotide-binding protein β3 (GNB3), also known as transducin β3 or Gβ3. The mutation in GNB3 destabilizes the protein and causes a loss of Gβ3 from photoreceptors and ON-bipolar cells. (Ritchey et al. 2010)FD increased ocular elongation in RGE eyes in a manner similar to that seen in wild-type (WT) eyes. By comparison, the excessive ocular elongation that results from hyperopic defocus was increased, whereas myopic defocus failed to significantly decrease ocular elongation in RGE eyes. Brief daily periods of unrestricted vision interrupting FD prevented ocular elongation in RGE chicks in a manner similar to that seen in WT chicks. Glucagonergic amacrine cells differentially expressed the immediate early gene Egr1 in response to growth-guiding stimuli in RGE retinas, but the defocus-dependent up-regulation of Egr1 was lesser in RGE retinas compared to that of WT retinas. We conclude that high visual acuity, and the retinal signaling mediated by Gβ3, is not required for emmetropization and the excessive ocular elongation caused by FD and hyperopic defocus. However, the loss of acuity and Gβ3 from RGE retinas causes enhanced responses to hyperopic defocus and diminished responses to myopic defocus. PMID:22824538
Density of ocular components of the bovine eye.
Su, Xiao; Vesco, Christina; Fleming, Jacquelyn; Choh, Vivian
2009-10-01
Density is essential for acoustic characterization of tissues and provides a basic input for ultrasound backscatter and absorption models. Despite the existence of extensive compilations of acoustic properties, neither unified data on ocular density nor comparisons of the densities between all ocular components can be found. This study was undertaken to determine the mass density of all the ocular components of the bovine eye. Liquid components were measured through mass/volume ratio, whereas solid tissues were measured with two different densitometry techniques based on Archimedes Principle. The first method determines the density by measuring dry and wet weight of the tissues. The second method consists of immersing the tissues in sucrose solutions of varying densities and observing their buoyancy. Although the mean densities for all tissues were found to be within 0.02 g/cm by both methods, only the sucrose solution method offered a consistent relative order for all measured ocular components, as well as a considerably smaller standard deviation (a maximum standard deviation of 0.004 g/cm for cornea). The lens was found to be the densest component, followed by the sclera, cornea, choroid, retina, aqueous, and vitreous humors. The consistent results of the sucrose solution tests suggest that the ocular mass density is a physical property that is more dependent on the compositional and structural characteristics of the tissue and than on population variability.
Liao, Xuan; Lin, Jia; Tian, Jing; Wen, BaiWei; Tan, QingQing; Lan, ChangJun
2018-06-01
To compare objective optical quality, ocular scattering and aberrations of eyes implanted with an aspheric monofocal intraocular lens (IOL) or an aspheric apodized diffractive multifocal IOL three months after surgery. Prospective consecutive nonrandomized comparative cohort study. A total of 80 eyes from 57 cataract patients were bilaterally or unilaterally implanted with monofocal (AcrySof IQ SN60WF) or multifocal (AcrySof IQ ReSTOR SN6AD1) IOLs. Respectively, 40 eyes of 27 patients were implanted with monofocal IOLs, and 40 eyes of 30 patients were implanted with multifocal IOLs. Ocular high-order aberration (HOA) values were obtained using Hartmann-Shack aberrometer; objective scatter index (OSI), modulation transfer function (MTF) cutoff, Strehl ratio (SR), and contrast visual acuity OV at 100%, 20%, and 9% were measured using Objective Quality Analysis System II (OQAS II). Ocular aberrations performed similar in both groups (p > 0.05). However, significantly higher values of OSI and lower values of MTF cutoff, SR and OV were found in the SN6AD1 group (p < 0.05). Both ocular scattering and wave-front aberrations play essential role in retinal image quality, which may be overestimated when only aberrations were taken into account. Combining the effect of ocular scattering with HOA will result in a more accurate assessment of the visual and optical quality.
Comparison of ocular comfort, vision, and SICS during silicone hydrogel contact lens daily wear.
Diec, Jennie; Evans, Victoria E; Tilia, Daniel; Naduvilath, Thomas; Holden, Brien A; Lazon de la Jara, Percy
2012-01-01
The aim of this study was to investigate the relationship between solution-induced corneal staining (SICS) and silicone hydrogel contact lens comfort and vision. A retrospective analysis of a series of open-label studies were conducted with 24 groups of approximately 40 participants, each wearing 1 of 6 silicone hydrogel contact lenses with 1 of 4 lens care products bilaterally for 3 months of daily wear. The presence of SICS and subjective ocular ratings were collected at 2 weeks and at 1 and 3 months. A total of 1,051 participants were enrolled. The participants with SICS rated significantly less favorably than did the participants without SICS for comfort during the day (7.9±1.7 vs. 8.5±1.4, P=0.03), comfort at the end of the day (6.6±2.1 vs. 7.4±1.9, P=0.03), overall dryness (7.4±1.9 vs. 8.0±1.7, P=0.04), dryness at the end of the day (6.7±2.2 vs. 7.5±2.1, P=0.01), feelings of burning and stinging (8.5±2.0 vs. 8.9±1.8, P=0.02), and overall vision (8.2±1.6 vs. 8.7±1.3, P<0.001). The participants with SICS had lower subjective comfort and vision compared with those who did not experience SICS.
The ocular biometric differences of diabetic patients.
Kocatürk, Tolga; Zengin, Mehmet Özgür; Cakmak, Harun; Evliçoglu, Gökhan Evren; Dündar, Sema Oruç; Omürlü, Imran Kurt; Unübol, Mustafa; Güney, Engin
2014-01-01
To investigate the differences in ocular biometric and keratometric characteristics in comparison with biometric measurements using the noncontact optical low coherence reflectometer (OLCR) (Lenstar LS 900, Haag-Streit) on diabetic patients. The eyes of 170 patients were included in this study, including 81 diabetic and 89 nondiabetic subjects. Optical biometric measurements of diabetic and nondiabetic patients (between the ages of 25 and 85 years) who applied to the ophthalmology clinic were noted from March to June 2013. Detailed ophthalmologic examinations were done for every subject. Biometric measurements were done using the noncontact OLCR device. Patient age ranged from 29 to 83 years. Subgroup analyses were done in diabetic patients according to their Hba1C levels. The minimum Hba1C value was 5.3, maximum was 12.4, and mean was 7.56 ± 1.48. The median duration of diabetes was 5 years (25th-75th percentile 3.00-11.75). Diabetic patients were found to have thicker lens and shallower anterior chamber in both eyes compared to nondiabetic control subjects. There were no statistical differences between the groups according to central corneal thickness, axial length, or keratometric values in both eyes. However, lens thicknesses were found to be thicker and anterior chamber depth values were found to be shallower in the diabetic group in both eyes. It may useful to determine eyeglasses prescription, refractive surgery calculation, lens selection, and previous cataract surgery according to biometric measurements after the regulation of blood glucose.
Bernstein, P S; Khachik, F; Carvalho, L S; Muir, G J; Zhao, D Y; Katz, N B
2001-03-01
There is increasing evidence that the macular pigment carotenoids, lutein and zeaxanthin, may play an important role in the prevention of age-related macular degeneration, cataract, and other blinding disorders. Although it is well known that the retina and lens are enriched in these carotenoids, relatively little is known about carotenoid levels in the uveal tract and in other ocular tissues. Also, the oxidative metabolism and physiological functions of the ocular carotenoids are not fully understood. Thus, we have set out to identify and quantify the complete spectrum of dietary carotenoids and their oxidative metabolites in a systematic manner in all tissues of the human eye in order to gain better insight into their ocular physiology. Human donor eyes were dissected, and carotenoid extracts from ocular tissues [retinal pigment epithelium/choroid (RPE/choroid), macula, peripheral retina, ciliary body, iris, lens, vitreous, cornea, and sclera] were analysed by high-performance liquid chromatography (HPLC). Carotenoids were identified and quantified by comparing their chromatographic and spectral profiles with those of authentic standards. Nearly all ocular structures examined with the exception of vitreous, cornea, and sclera had quantifiable levels of dietary (3R,3'R,6'R)-lutein, zeaxanthin, their geometrical (E / Z) isomers, as well as their metabolites, (3R,3'S,6'R)-lutein (3'-epilutein) and 3-hydroxy-beta,epsilon-caroten-3'-one. In addition, human ciliary body revealed the presence of monohydroxycarotenoids and hydrocarbon carotenoids, while only the latter group was detected in human RPE/choroid. Uveal structures (iris, ciliary body, and RPE/choroid) account for approximately 50% of the eye's total carotenoids and approximately 30% of the lutein and zeaxanthin. In the iris, these pigments are likely to play a role in filtering out phototoxic short-wavelength visible light, while they are more likely to act as antioxidants in the ciliary body. Both mechanisms, light screening and antioxidant, may be operative in the RPE/choroid in addition to a possible function of this tissue in the transport of dihydroxycarotenoids from the circulating blood to the retina. This report lends further support for the critical role of lutein, zeaxanthin, and other ocular carotenoids in protecting the eye from light-induced oxidative damage and aging. Copyright 2001 Academic Press.
Thermal safety of ultrasound-enhanced ocular drug delivery: A modeling study
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nabili, Marjan, E-mail: mnabili@gwmail.gwu.edu; Geist, Craig, E-mail: cgeist@mfa.gwu.edu, E-mail: zderic@gwu.edu; Zderic, Vesna, E-mail: cgeist@mfa.gwu.edu, E-mail: zderic@gwu.edu
Purpose: Delivery of sufficient amounts of therapeutic drugs into the eye for treatment of various ocular diseases is often a challenging task. Ultrasound was shown to be effective in enhancing ocular drug delivery in the authors’ previous in vitro and in vivo studies. Methods: The study reported here was designed to investigate the safety of ultrasound application and its potential thermal effects in the eye using PZFlex modeling software. The safety limit in this study was set as a temperature increase of no more than 1.5 °C based on regulatory recommendations and previous experimental safety studies. Acoustic and thermal specifications ofmore » different human eye tissues were obtained from the published literature. The tissues of particular interest in this modeling safety study were cornea, lens, and the location of optic nerve in the posterior eye. Ultrasound application was modeled at frequencies of 400 kHz–1 MHz, intensities of 0.3–1 W/cm{sup 2}, and exposure duration of 5 min, which were the parameters used in the authors’ previous drug delivery experiments. The baseline eye temperature was 37 °C. Results: The authors’ results showed that the maximal tissue temperatures after 5 min of ultrasound application were 38, 39, 39.5, and 40 °C in the cornea, 39.5, 40, 42, and 43 °C in the center of the lens, and 37.5, 38.5, and 39 °C in the back of the eye (at the optic nerve location) at frequencies of 400, 600, 800 kHz, and 1 MHz, respectively. Conclusions: The ocular temperatures reached at higher frequencies were considered unsafe based on current recommendations. At a frequency of 400 kHz and intensity of 0.8 W/cm{sup 2} (parameters shown in the authors’ previous in vivo studies to be optimal for ocular drug delivery), the temperature increase was small enough to be considered safe inside different ocular tissues. However, the impact of orbital bone and tissue perfusion should be included in future modeling efforts to determine the safety of this method in the whole orbit especially regarding potential adverse optic nerve heating at the location of the bone.« less
Characterisation of the metabolome of ocular tissues and post-mortem changes in the rat retina.
Tan, Shi Z; Mullard, Graham; Hollywood, Katherine A; Dunn, Warwick B; Bishop, Paul N
2016-08-01
Time-dependent post-mortem biochemical changes have been demonstrated in donor cornea and vitreous, but there have been no published studies to date that objectively measure post-mortem changes in the retinal metabolome over time. The aim of the study was firstly, to investigate post-mortem, time-dependent changes in the rat retinal metabolome and secondly, to compare the metabolite composition of healthy rat ocular tissues. To study post-mortem changes in the rat retinal metabolome, globes were enucleated and stored at 4 °C and sampled at 0, 2, 4, 8, 24 and 48 h post-mortem. To study the metabolite composition of rat ocular tissues, eyes were dissected immediately after culling to isolate the cornea, lens, vitreous and retina, prior to storing at -80 °C. Tissue extracts were subjected to Gas Chromatograph Mass Spectrometry (GC-MS) and Ultra High Performance Liquid Chromatography Mass Spectrometry (UHPLC-MS). Generally, the metabolic composition of the retina was stable for 8 h post-mortem when eyes were stored at 4 °C, but showed increasing changes thereafter. However, some more rapid changes were observed such as increases in TCA cycle metabolites after 2 h post-mortem, whereas some metabolites such as fatty acids only showed decreases in concentration from 24 h. A total of 42 metabolites were identified across the ocular tissues by GC-MS (MSI level 1) and 2782 metabolites were annotated by UHPLC-MS (MSI level 2) according to MSI reporting standards. Many of the metabolites detected were common to all of the tissues but some metabolites showed partitioning between different ocular structures with 655, 297, 93 and 13 metabolites being uniquely detected in the retina, lens, cornea and vitreous respectively. Only a small percentage (1.6%) of metabolites found in the vitreous were only detected in the retina and not other tissues. In conclusion, mass spectrometry-based techniques have been used for the first time to compare the metabolic composition of different ocular tissues. The metabolite composition of the retina stored at 4 °C post-mortem is mostly stable for at least 8 h. Copyright © 2016 Elsevier Ltd. All rights reserved.
Cammarata, P R; Zhou, C; Chen, G; Singh, I; Reeves, R E; Kuszak, J R; Robinson, M L
1999-07-01
Intracellular osmotic stress is believed to be linked to the advancement of diabetic cataract. Although the accumulation of organic osmolytes (myo-inositol, sorbitol, taurine) is thought to protect the lens by maintaining osmotic homeostasis, the physiologic implication of osmotic imbalance (i.e., hyperosmotic stress caused by intracellular over-accumulation of organic osmolytes) on diabetic cataract formation is not clearly understood. Studies from this laboratory have identified several osmotic compensatory mechanisms thought to afford the lens epithelium, but not the lens fibers, protection from water stress during intervals of osmotic crisis. This model is founded on the supposition that the fibers of the lens are comparatively more susceptible to damage by osmotic insult than is the lens epithelium. To test this premise, several transgenic mouse lines were developed that over-express the bovine sodium/myo-inositol cotransporter (bSMIT) gene in lens fiber cells. Of the several transgenic mouse lines generated, two, MLR14 and MLR21, were analyzed in detail. Transgenic mRNA expression was analyzed in adult and embryonic transgenic mice by a coupled reverse transcriptase-polymerase chain reaction (RT-PCR) and in situ hybridization on embryonic tissue sections, respectively. Intralenticular myo-inositol content from individual mouse lenses was quantified by anion exchange chromatography and pulsed electrochemical detection. Ocular histology of embryonic day 15.5 (E15.5) embryos from both transgenic (TG) families was analyzed and compared to their respective nontransgenic (NTG) littermates. Both RT-PCR and in situ hybridization determined that transgene expression was higher in line MLR21 than in line MLR14. Consistent with this, intralenticular myo-inositol from MLR21 TG mice was markedly higher compared with NTG littermates or MLR14 TG mice. Histologic analysis of E15.5 MLR21 TG embryos disclosed a marked swelling in the differentiating fibers of the bow region and subcapsular fibers of the central zone, whereas the lens epithelium appeared morphologically normal. The lenticular changes, initiated early during lens development in TG MLR21 embryos, result in severe bilateral nuclear cataracts readily observable in neonates under normal rearing and dietary conditions. In contrast, TG MLR14 pups reared under standard conditions produced no lens opacity. Lens fiber swelling and related cataractous outgrowth positively correlated to the degree of lens bSMIT gene expression and intralenticular myo-inositol content. The affected (i.e., swollen) lens fibers appeared to be unable to cope with the water stress generated by the transgene-induced over-accumulation of myo-inositol and, as a result of this inability to osmoregulate, suffered osmotic damage due to water influx.
Treatment of contact lens related dry eye with antibacterial honey.
Wong, Daniel; Albietz, Julie M; Tran, Huan; Du Toit, Cimonette; Li, Anita Hui; Yun, Tina; Han, Jee; Schmid, Katrina L
2017-12-01
Contact lens induced dry eye affects approximately 50% of contact lens wearers. The aim was to assess the effects of Manuka (Leptospermum sp.) honey eye drops (Optimel, Melcare, Australia) on dry eye in contact lens wearers. The safety of the honey eye drops in contact lens wear and contact lens wearers' compliance were also evaluated. Prospective, randomised, cross over study, examiner masked, pilot treatment trial. Twenty-four participants aged 20 to 55 years with contact lens related dry eye were recruited and randomised to two treatment groups; 20 completed the study. One group used Optimel eye drops twice a day for two weeks followed by conventional lubricant (Systane Ultra, Alcon) therapy for two weeks; the other group completed the treatments in the reverse order. Before and after each treatment dry eye symptomology, ocular surface inflammation, and tear quantity and quality were assessed. Participants completed a daily log detailing their usage of treatments and any issues. Dry eye symptoms improved significantly after Optimel treatment. Patients with more severe symptoms at baseline showed a greater improvement in symptoms. No significant differences were observed in the objective signs of dry eye; presumably because of the short treatment duration. Seventy-five% of contact lens wearers reported good adherence to Optimel treatment and 95% reported no issues using this product. Optimel Eye Drops reduce the symptoms of dry eye in contact lens wearers and are safe to use. A longer treatment period to assess the effect on clinical signs of dry eye is required. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
Adenovirus-mediated heme oxygenase-1 gene transfer into rabbit ocular tissues.
Abraham, N G; da Silva, J L; Lavrovsky, Y; Stoltz, R A; Kappas, A; Dunn, M W; Schwartzman, M L
1995-10-01
Heme oxygenase-1 (HO-1) is a stress protein induced up to 100-fold within a few hours after exposure to oxidative stress, and it has been shown to counteract oxidative injury induced by ultraviolet light or free radicals. The current study was undertaken to determine whether the HO-1 gene can be introduced into adult rabbit ocular tissues by microinjection of a recombinant replication-deficient adenovirus human HO-1 cDNA (Adv-HHO). Human HO-1 gene was used for transfection studies to differentiate endogenous from transfected HO. The purified Adv-HHO construct (10(8) pfu/ml) was mixed with lipofectamine and microinjected into the anterior chamber, vitreous cavity, and subretinal space of New Zealand rabbit eyes. After 2 weeks, total RNA was extracted from different ocular tissues, reverse transcription-polymerase chain reaction was performed using specific human HO-1 primers, and amplification products were subjected to Southern hybridization. Transfection with the Adv-HHO construct into rabbit corneal epithelial cells in culture resulted in a functional expression of the human HO-1 gene; the human HO-1 mRNA was detected, and enzyme activity increased threefold. Human HO-1 mRNA was detected in the retina after microinjection of the Adv-HHO construct into the subretinal space. Microinjection into the vitreous resulted in HO-1 mRNA expression in the corneal endothelium, iris, lens, and retina; after intracameral injection of the Adv-HHO construct, human HO-1 mRNA was detected in corneal epithelium and endothelium, ciliary body, lens, and iris. Regardless of the injection site, transfected human HO-1 mRNA was undetectable in tissues outside the eye, that is, brain, liver, and kidney. These results demonstrated a tissue-selective functional transfer of the human HO-1 gene into rabbit ocular tissues in vivo. This technique may be a promising means for delivering HO-1 gene in vivo as a protective mechanism against oxidative stress that contributes to the pathogenesis of ocular diseases such as cataract, light-induced injury, age-related macular degeneration, and diabetic retinopathy.
CUSTOM OPTIMIZATION OF INTRAOCULAR LENS ASPHERICITY
Koch, Douglas D.; Wang, Li
2007-01-01
Purpose To investigate the optimal amount of ocular spherical aberration (SA) in an intraocular lens (IOL) to maximize optical quality. Methods In 154 eyes of 94 patients aged 40 to 80 years, implantation of aspheric IOLs was simulated with different amounts of SA to produce residual ocular SA from −0.30 μm to +0.30 μm. Using the VOL-CT program (Sarver & Associates, Carbondale, Illinois), corneal wavefront aberrations up to 6th order were computed from corneal topographic elevation data (Humphrey Atlas, Carl Zeiss Meditec, Inc, Dublin, California). Using the ZernikeTool program (Advanced Medical Optics, Inc, Santa Ana, California), the polychromatic point spread function with Stiles-Crawford effect was calculated for the residual ocular higher-order aberrations (HOAs, 3rd to 6th order, 6-mm pupil), assuming fully corrected 2nd-order aberrations. Five parameters were used to quantify optical image quality, and we determined the residual ocular SA at which the maximal image quality was achieved for each eye. Stepwise multiple regression analysis was performed to assess the predictors for optimal SA of each eye. Results The optimal SA varied widely among eyes. Most eyes had best image quality with low amounts of negative SA. For modulation transfer function volume up to 15 cycles/degree, the amount of optimal SA could be predicted based on other HOAs of the cornea with coefficient of multiple determination (R2) of 79%. Eight Zernike terms significantly contributed to the optimal SA in this model; the order of importance to optimal SA from most to least was: Z60, Z62, Z42, Z53, Z64, Z3−1, Z33, and Z31. For the other 4 measures of visual quality, the coefficients of determination varied from 32% to 63%. Conclusion The amount of ocular SA producing best image quality varied widely among subjects and could be predicted based on corneal HOAs. Selection of an aspheric IOL should be customized according to the full spectrum of corneal HOAs and not 4th-order SA alone. PMID:18427592
Ruggeri, Marco; Uhlhorn, Stephen R.; De Freitas, Carolina; Ho, Arthur; Manns, Fabrice; Parel, Jean-Marie
2012-01-01
Abstract: An optical switch was implemented in the reference arm of an extended depth SD-OCT system to sequentially acquire OCT images at different depths into the eye ranging from the cornea to the retina. A custom-made accommodation module was coupled with the delivery of the OCT system to provide controlled step stimuli of accommodation and disaccommodation that preserve ocular alignment. The changes in the lens shape were imaged and ocular distances were dynamically measured during accommodation and disaccommodation. The system is capable of dynamic in vivo imaging of the entire anterior segment and eye-length measurement during accommodation in real-time. PMID:22808424
Ruggeri, Marco; Uhlhorn, Stephen R; De Freitas, Carolina; Ho, Arthur; Manns, Fabrice; Parel, Jean-Marie
2012-07-01
An optical switch was implemented in the reference arm of an extended depth SD-OCT system to sequentially acquire OCT images at different depths into the eye ranging from the cornea to the retina. A custom-made accommodation module was coupled with the delivery of the OCT system to provide controlled step stimuli of accommodation and disaccommodation that preserve ocular alignment. The changes in the lens shape were imaged and ocular distances were dynamically measured during accommodation and disaccommodation. The system is capable of dynamic in vivo imaging of the entire anterior segment and eye-length measurement during accommodation in real-time.
Visual and anatomic outcomes of golf ball-related ocular injuries.
Park, S J; Park, K H; Heo, J W; Woo, S J
2014-03-01
To investigate the characteristics and prognoses of golf ball-related ocular injuries (GROIs) using standardized terminology, classification, and scoring systems. Twenty-two GROI patients were assessed using the Birmingham Eye Trauma Terminology, Ocular Trauma Classification Group (OTCG) classification, and Ocular Trauma Score. Globe preservation and final visual acuity (FVA) were assessed according to the injury severity categorical designation. Fourteen patients were injured on golf courses and eight on driving ranges. Nine patients (40.9%) had open-globe injuries (five ruptures (22.7%), four penetrating injuries (18.2%)). All rupture cases required enucleation, whereas penetrating injury cases did not (the FVA ranged from 20/100 to no light perception). In open-globe injuries, wearing glasses protected against rupture (P=0.008). Thirteen patients sustained closed-globe injuries that were accompanied by lens subluxation (38.5%), choroidal rupture (30.8%), macular commotio retinae (38.5%), and traumatic optic neuropathy (7.7%). Twelve (54.5%) patients had orbital wall fractures. The mean number of related surgeries required was 1.5±1.7 across all patients. Eyes with GROIs had devastating FVA and globe preservation status, especially those with open-globe injuries. Observing golf rules and improving driving-range facilities are essential for preventing GROIs. Protective eyewear may reduce ocular damage from GROIs, especially globe rupture.
Visual and anatomic outcomes of golf ball-related ocular injuries
Park, S J; Park, K H; Heo, J W; Woo, S J
2014-01-01
Aims To investigate the characteristics and prognoses of golf ball-related ocular injuries (GROIs) using standardized terminology, classification, and scoring systems. Methods Twenty-two GROI patients were assessed using the Birmingham Eye Trauma Terminology, Ocular Trauma Classification Group (OTCG) classification, and Ocular Trauma Score. Globe preservation and final visual acuity (FVA) were assessed according to the injury severity categorical designation. Results Fourteen patients were injured on golf courses and eight on driving ranges. Nine patients (40.9%) had open-globe injuries (five ruptures (22.7%), four penetrating injuries (18.2%)). All rupture cases required enucleation, whereas penetrating injury cases did not (the FVA ranged from 20/100 to no light perception). In open-globe injuries, wearing glasses protected against rupture (P=0.008). Thirteen patients sustained closed-globe injuries that were accompanied by lens subluxation (38.5%), choroidal rupture (30.8%), macular commotio retinae (38.5%), and traumatic optic neuropathy (7.7%). Twelve (54.5%) patients had orbital wall fractures. The mean number of related surgeries required was 1.5±1.7 across all patients. Conclusion Eyes with GROIs had devastating FVA and globe preservation status, especially those with open-globe injuries. Observing golf rules and improving driving-range facilities are essential for preventing GROIs. Protective eyewear may reduce ocular damage from GROIs, especially globe rupture. PMID:24384962
Pérez Bartolomé, Francisco; Martínez de la Casa, Jose María; Camacho Bosca, Irene; Sáenz-Francés, Federico; Aguilar Munoa, Soledad; Martín Juan, Alberto; Garcia-Feijoo, Julian
2018-01-01
To examine interrelations between corneal biomechanics, ocular biometric variables and optic disc size (ODS), lamina cribosa depth (LCD) or thickness (LCT) in a healthy population. In a cross-sectional case-control study, the following measurements were made in 81 eyes of 81 participants: axial length, anterior chamber depth, lens thickness, and central corneal thickness using the optical biometer Lenstar LS900; and corneal hysteresis (CH), corneal resistance factor (CRF), Goldman-correlated intraocular pressure (IOPg), and corneal-compensated IOP (IOPcc) using the Ocular Response Analyzer. Serial horizontal enhanced depth imaging optical coherence tomography (EDI OCT) B-scans of the optic nerve head were obtained in each participant. Mean ODS, mean LCD, and mean LCT were measured in 11 equally spaced horizontal B-scans, excluding the LC insertion area under Bruch's membrane and scleral rim. LCD was measured in 74 of 81 eyes (91.36%); LCT in 60/81 (75.3%); ODS in 81/81 (100%). CRF was poorly, but significantly, correlated with LCT (Pearson's R = 0.264; P = 0.045). IOPcc, IOPg, CH, and ocular biometrics variables were poorly (non-significantly) correlated with LCD, LCT, and ODS. CRF was poorly but directly correlated with LCT. No association was detected between CH or ocular biometric variables and ODS, LCD, or LCT.
Guzey, M; Karadede, S; Dogan, Z; Satici, A
2000-01-01
The objective of this study was to compare the efficacy of ketorolac-tobramycin combination with fluorometholone-tobramycin combination in the control of ocular inflammation after endocapsular phacoemulsification cataract surgery with scleral tunnel incision. This was a prospective, randomized, investigator masked, 2-week, single-center study. Ocular examinations were carried out preoperatively and postoperatively on days 1 (baseline), 2, 3, 7, and 14. There were 60 patients (30 in each treatment group) undergoing uncomplicated cataract-lens implant surgery enrolled and randomized in the study. The baseline parameters were similar in the two study groups. At each visit comprehensive ocular examinations were performed and a 4-point (0 to 3) grading system was used to record findings of the burning/stinging sensation, blurred vision, ocular discomfort, conjunctival hyperemia, anterior chamber flare, and anterior chamber cells. There was no statistically significant difference between the treatment groups in the findings of the ocular inflammation at any of the postoperative visits. Both treatments were equally well tolerated. This study suggests that ketorolac may be an alternative to some corticosteroids (fluorometholone). It is generally accepted that fluorometholone is not as potent an anti-inflammatory as prednisolone the most commonly used steroid following cataract extraction.
Performance of three multipurpose disinfecting solutions with a silicone hydrogel contact lens.
García-Porta, Nery; Rico-del-Viejo, Laura; Ferreira-Neves, Helena; Peixoto-de-Matos, Sofia C; Queirós, Antonio; González-Méijome, José M
2015-01-01
To evaluate the clinical performance of a silicone hydrogel (Si-Hy) soft contact lens (CL) in combination with three different multipurpose disinfecting solutions (MPDSs). This was a prospective, randomized, single-masked, crossover, and comparative study in which 31 habitual soft CL wearers were randomly assigned to one of the three MPDSs (Synergi, COMPLETE RevitaLens, and OPTI-FREE PureMoist) for 1 month with a 1-week wash-out period between each exposure. All subjects were successfully refitted with a Si-Hy CL (Biofinity). Subjects were then scheduled for follow-up visits after 1 month of lens wear, being evaluated at 2 and 8 hours after lens insertion. Visual Analogue Scales (VAS) were used to gauge comfort rating. The tarsal conjunctiva showed a significantly different degree of lid redness between the MPDSs at the 2-hour visit (P < 0.05, Kruskal-Wallis test), being lower for COMPLETE RevitaLens compared to the other two MPDSs (Mann-Whitney U test). Furthermore, a significantly different degree of lid roughness at the 8-hour visit was seen (P < 0.05, Kruskal-Wallis test), being higher for Synergi (Mann-Whitney U test). The subjective comfort was similar with the three MPDSs. Tarsal conjunctival response should be also considered in the context of the clinical performance of MPDs at the ocular surface.
Pigment dispersion syndrome associated with spontaneous subluxation of crystalline lens.
Veerwal, Vikas; Goyal, Jawahar Lal; Jain, Parul; Arora, Ritu
2017-01-01
Pigment dispersion syndrome (PDS) is an ocular condition characterized by a dispersion of iris pigment throughout the eye. This pigment is deposited in a characteristic manner on the corneal endothelium as Krukenberg's spindle, anterior surface of the iris, in the trabecular meshwork, on the lens and zonule and occasionally on the anterior hyaloid face. Even with deposition of pigment on zonular fibers, no zonular weakness, or zonular dehiscence has been reported in these cases. We report a unique case of PDS with bilateral spontaneous subluxation of crystalline lens. With characteristic findings of pigment distribution in both his eyes, the patient had concave iris configuration with heavily pigmented trabecular meshwork confirming the diagnosis of PDS. The patient had bilateral 180° temporal subluxation of crystalline lens in both his eyes. The usual cause of lens subluxation such as Marfan's Syndrome and Ehler's Danlos Syndrome was ruled out. The patient underwent right eye followed by left eye intracapsular cataract extraction with ab-interno technique with postoperative best-corrected visual acuity (BCVA) of 6/9 in both eyes. Spontaneous subluxation of crystalline lens in isolated PDS is not known to occur and has been reported by means of this case. We recommend a thorough assessment of zonular status in all cases of PDS.
Biological and Clinical Implications of Lysozyme Deposition on Soft Contact Lenses
Omali, Negar Babaei; Subbaraman, Lakshman N.; Coles-Brennan, Chantal; Fadli, Zohra; Jones, Lyndon W.
2015-01-01
ABSTRACT Within a few minutes of wear, contact lenses become rapidly coated with a variety of tear film components, including proteins, lipids, and mucins. Tears have a rich and complex composition, allowing a wide range of interactions and competitive processes, with the first event observed at the interface between a contact lens and tear fluid being protein adsorption. Protein adsorption on hydrogel contact lenses is a complex process involving a variety of factors relating to both the protein in question and the lens material. Among tear proteins, lysozyme is a major protein that has both antibacterial and anti-inflammatory functions. Contact lens materials that have high ionicity and high water content have an increased affinity to accumulate lysozyme during wear, when compared with other soft lens materials, notably silicone hydrogel lenses. This review provides an overview of tear film proteins, with a specific focus on lysozyme, and examines various factors that influence protein deposition on contact lenses. In addition, the impact of lysozyme deposition on various ocular physiological responses and bacterial adhesion to lenses and the interaction of lysozyme with other tear proteins are reviewed. This comprehensive review suggests that deposition of lysozyme on contact lens materials may provide a number of beneficial effects during contact lens wear. PMID:26002002
Senthilkumari, Srinivasan; Talwar, Badri; Dharmalingam, Kuppamuthu; Ravindran, Ravilla D; Jayanthi, Ramamurthy; Sundaresan, Periasamy; Saravanan, Charu; Young, Ian S; Dangour, Alan D; Fletcher, Astrid E
2014-07-01
We have previously reported low concentrations of plasma ascorbate and low dietary vitamin C intake in the older Indian population and a strong inverse association of these with cataract. Little is known about ascorbate levels in aqueous humor and lens in populations habitually depleted of ascorbate and no studies in any setting have investigated whether genetic polymorphisms influence ascorbate levels in ocular tissues. Our objectives were to investigate relationships between ascorbate concentrations in plasma, aqueous humor and lens and whether these relationships are influenced by Single Nucleotide Polymorphisms (SNPs) in sodium-dependent vitamin C transporter genes (SLC23A1 and SLC23A2). We enrolled sixty patients (equal numbers of men and women, mean age 63 years) undergoing small incision cataract surgery in southern India. We measured ascorbate concentrations in plasma, aqueous humor and lens nucleus using high performance liquid chromatography. SLC23A1 SNPs (rs4257763, rs6596473) and SLC23A2 SNPs (rs1279683 and rs12479919) were genotyped using a TaqMan assay. Patients were interviewed for lifestyle factors which might influence ascorbate. Plasma vitamin C was normalized by a log10 transformation. Statistical analysis used linear regression with the slope of the within-subject associations estimated using beta (β) coefficients. The ascorbate concentrations (μmol/L) were: plasma ascorbate, median and inter-quartile range (IQR), 15.2 (7.8, 34.5), mean (SD) of aqueous humor ascorbate, 1074 (545) and lens nucleus ascorbate, 0.42 (0.16) (μmol/g lens nucleus wet weight). Minimum allele frequencies were: rs1279683 (0.28), rs12479919 (0.30), rs659647 (0.48). Decreasing concentrations of ocular ascorbate from the common to the rare genotype were observed for rs6596473 and rs12479919. The per allele difference in aqueous humor ascorbate for rs6596473 was -217 μmol/L, p < 0.04 and a per allele difference in lens nucleus ascorbate of -0.085 μmol/g, p < 0.02 for rs12479919. The β coefficients for the regression of log10 plasma ascorbate on aqueous humor ascorbate were higher for the GG genotype of rs6596473: GG, β = 1460 compared to carriage of the C allele, CG, β = 1059, CC, β = 1132, p interaction = 0.1. In conclusion we found that compared to studies in well-nourished populations, ascorbate concentrations in the plasma, aqueous humor and lens nucleus were low. We present novel findings that polymorphisms in SLC23A1/2 genes influenced ascorbate concentration in aqueous humor and lens nucleus. Copyright © 2014 Elsevier Ltd. All rights reserved.
Huang, Yi-Shiang; Bertrand, Virginie; Bozukova, Dimitriya; Pagnoulle, Christophe; Labrugère, Christine; De Pauw, Edwin; De Pauw-Gillet, Marie-Claire; Durrieu, Marie-Christine
2014-01-01
Posterior Capsular Opacification (PCO) is the capsule fibrosis developed on implanted IntraOcular Lens (IOL) by the de-differentiation of Lens Epithelial Cells (LECs) undergoing Epithelial Mesenchymal Transition (EMT). Literature has shown that the incidence of PCO is multifactorial including the patient's age or disease, surgical technique, and IOL design and material. Reports comparing hydrophilic and hydrophobic acrylic IOLs have shown that the former has more severe PCO. On the other hand, we have previously demonstrated that the adhesion of LECs is favored on hydrophobic compared to hydrophilic materials. By combining these two facts and contemporary knowledge in PCO development via the EMT pathway, we propose a biomimetically inspired strategy to promote LEC adhesion without de-differentiation to reduce the risk of PCO development. By surface grafting of a cell adhesion molecule (RGD peptide) onto the conventional hydrophilic acrylic IOL material, the surface-functionalized IOL can be used to reconstitute a capsule-LEC-IOL sandwich structure, which has been considered to prevent PCO formation in literature. Our results show that the innovative biomaterial improves LEC adhesion, while also exhibiting similar optical (light transmittance, optical bench) and mechanical (haptic compression force, IOL injection force) properties compared to the starting material. In addition, compared to the hydrophobic IOL material, our bioactive biomaterial exhibits similar abilities in LEC adhesion, morphology maintenance, and EMT biomarker expression, which is the crucial pathway to induce PCO. The in vitro assays suggest that this biomaterial has the potential to reduce the risk factor of PCO development. PMID:25501012
Huang, Yi-Shiang; Bertrand, Virginie; Bozukova, Dimitriya; Pagnoulle, Christophe; Labrugère, Christine; De Pauw, Edwin; De Pauw-Gillet, Marie-Claire; Durrieu, Marie-Christine
2014-01-01
Posterior Capsular Opacification (PCO) is the capsule fibrosis developed on implanted IntraOcular Lens (IOL) by the de-differentiation of Lens Epithelial Cells (LECs) undergoing Epithelial Mesenchymal Transition (EMT). Literature has shown that the incidence of PCO is multifactorial including the patient's age or disease, surgical technique, and IOL design and material. Reports comparing hydrophilic and hydrophobic acrylic IOLs have shown that the former has more severe PCO. On the other hand, we have previously demonstrated that the adhesion of LECs is favored on hydrophobic compared to hydrophilic materials. By combining these two facts and contemporary knowledge in PCO development via the EMT pathway, we propose a biomimetically inspired strategy to promote LEC adhesion without de-differentiation to reduce the risk of PCO development. By surface grafting of a cell adhesion molecule (RGD peptide) onto the conventional hydrophilic acrylic IOL material, the surface-functionalized IOL can be used to reconstitute a capsule-LEC-IOL sandwich structure, which has been considered to prevent PCO formation in literature. Our results show that the innovative biomaterial improves LEC adhesion, while also exhibiting similar optical (light transmittance, optical bench) and mechanical (haptic compression force, IOL injection force) properties compared to the starting material. In addition, compared to the hydrophobic IOL material, our bioactive biomaterial exhibits similar abilities in LEC adhesion, morphology maintenance, and EMT biomarker expression, which is the crucial pathway to induce PCO. The in vitro assays suggest that this biomaterial has the potential to reduce the risk factor of PCO development.
Growth of the eye lens: I. Weight accumulation in multiple species
2014-01-01
Purpose To examine the accumulation of wet and/or dry weight in the ocular lens as a function of age in different species. Methods Wet weights and/or fixed dry weights were obtained from measurements in the author’s laboratory and from the literature for over 14,000 lenses of known-ages, representing 130 different species. Various algorithms were tested to determine the most suitable for describing the relationship between lens weight and age. Results For 126 of the species examined, lens growth is continuous throughout life but asymptotic and can be reasonably described with a single logistic equation, W=Wm e-(k/A), where W is lens wet or dry weight; Wm is the maximum asymptotic weight, k is the logistic growth constant and A is the time from conception. For humans, elephants, hippopotami, minks, wild goats and woodchucks, lens growth appears to be biphasic. No gender differences could be detected in the lens weights for 70 species but male lenses are reportedly 10% larger than those of females in northern fur seals and pheasants. Dry weight accumulation is faster than that for wet weight in all species except birds and reptiles where the rates are the same. Low lens growth rates are associated with small animals with short gestation periods and short life spans. Conclusions Lens growth is continuous throughout life and, for most species, is independent of gender. For most, growth takes place through a monophasic asymptotic mode and is unaffected by events such as hibernation. This makes lens weight measurement a reliable tool for age determination of species culled in the wild. Compaction of the growing lens generates different properties, appropriate to an animal's lifestyle. How these events are controlled remains to be established. PMID:24715758
Williams, David; Adeyeye, Nina; Visser, Erni
2017-01-01
In this study we aimed to examine wild European hedgehogs (Erinaceus europaeus) in rescue centres and to determine ocular abnormalities in this animal population. Three hundred animals varying in age from 2 months to 5 years were examined, 147 being male and 153 female. All animals were evaluated with direct and indirect ophthalmoscopy and slit lamp biomicroscopy in animals where lesions were detected. Tonometry using the Tonovet rebound tonometer was undertaken in selected animals as was assessment of tear production using the Schirmer I tear test. Four animals were affected by orbital infection, 3 were anophthalmic, 2 unilaterally and one bilaterally, 3 by conjunctivitis, 3 by non-ulcerative keratitis and 4 by uveitis with corneal oedema. Fifty seven animals were affected by cataract, 54 with bilateral nuclear lens opacities. Twenty six of these animals were young animals considered too small to hibernate. This report documents the first prospective study of ocular disease in the European hedgehog. The predominant finding was bilateral nuclear cataract seen particularly in young poorly growing animals. Investigation into the potential causation of cataracts by poor nutrition or poor feeding ability by lens opacification requires further study. PMID:29038778
[Power in the periphery of several aspheric eyeglasses for aphakic patients].
Simonet, P
1984-01-01
A special device adapted to a Nikon projection vertexometer permits the power to be measured in the periphery of recent aspheric aphakic lenses. The peripheral power is measured with respect to the vertex sphere. A blended lenticular aspheric lens and three types of zonal aspheric full field lenses are studied, with various base curves on three samples. Four meridians of each lens are evaluated with ocular rotations varying by 5 degrees step up to 35 degrees at least. The results show a variable oblique astigmatism and a high under-correction of the mean oblique power for the Welsh 4 drop. The other zonal aspheric lenses give only a slight improvement of the peripheral powers compared with some conventional aspheric lenses. The Omega lens shows a reasonable correction of off-axis power errors up to 30 degrees. Beyond, the powers variation follows the general characteristics of blended lenticular aspheric lenses.
Zhao, Peili; Xu, Jinku; Zhang, Yongchun; Zhu, Weiyue; Cui, Yuezhi
2018-09-01
Refractive index (RI) is an important parameter for contact lens biomaterials. In this paper, a novel polymerizable-group capped ZnS nanoparticle (NP) was synthesized by chemical link between hydroxyl group on the surface of ZnS (ME-capped) and isocyanate group of polymerizable molecule of 2-isocyanatoethyl methacrylate. Then the ZnS NP copolymerized with monomer of 2-hydroxyethyl methacrylate (HEMA) and N,N-dimethylacrylamide (DMA) to prepare high refractive index hydrogel contact lens with high content of inorganic ZnS NP. Increasing polymerizable-group capped ZnS content in the hydrogels improved its RI value and mechanical properties, however decreased slightly its transmittance, equilibrium (ESR) and lysozyme deposition on the hydrogel surface. The ZnS-containing hydrogels possessed good cytocompatibility and in vivo biocompatibility in rabbit eyes, demonstrating a potential application as high RI ocular refractive correction biomaterial. Copyright © 2018 Elsevier B.V. All rights reserved.
Beebe, David C; Shui, Ying-Bo; Siegfried, Carla J; Holekamp, Nancy M; Bai, Fang
2014-05-01
Oxygen levels in the eye are generally low and tightly regulated. Oxygen enters the eye largely by diffusion from retinal arterioles and through the cornea. In intact eyes, oxygen from the retinal arterioles diffuses into the vitreous body. There is a decreasing oxygen gradient from the retina to the lens, established by oxygen consumption by ascorbate in the vitreous fluid and lens metabolism. Age-related degeneration of the vitreous body or removal during vitrectomy exposes the posterior of the lens to increased oxygen, causing nuclear sclerotic cataracts. Lowering oxygen in the vitreous, as occurs in patients with ischemic diabetic retinopathy, protects against cataracts after vitrectomy. Vitrectomy and cataract surgery increase oxygen levels at the trabecular meshwork and with it the risk of open angle glaucoma. Two additional risk factors for glaucoma, African heritage and having a thinner cornea, are also associated with increased oxygen in the anterior chamber angle. Preservation of the vitreous body and the lens, two important oxygen consumers, would protect against nuclear sclerotic cataracts and open angle glaucoma. Delaying removal of the lens for as long as possible after vitrectomy would be an important step in delaying ocular hypertension and glaucoma progression.
The use of contact lens telescopic systems in low vision rehabilitation.
Vincent, Stephen J
2017-06-01
Refracting telescopes are afocal compound optical systems consisting of two lenses that produce an apparent magnification of the retinal image. They are routinely used in visual rehabilitation in the form of monocular or binocular hand held low vision aids, and head or spectacle-mounted devices to improve distance visual acuity, and with slight modifications, to enhance acuity for near and intermediate tasks. Since the advent of ground glass haptic lenses in the 1930's, contact lenses have been employed as a useful refracting element of telescopic systems; primarily as a mobile ocular lens (the eyepiece), that moves with the eye. Telescopes which incorporate a contact lens eyepiece significantly improve the weight, comesis, and field of view compared to traditional spectacle-mounted telescopes, in addition to potential related psycho-social benefits. This review summarises the underlying optics and use of contact lenses to provide telescopic magnification from the era of Descartes, to Dallos, and the present day. The limitations and clinical challenges associated with such devices are discussed, along with the potential future use of reflecting telescopes incorporated within scleral lenses and tactile contact lens systems in low vision rehabilitation. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
Sutureless Fixation of Amniotic Membrane for Therapy of Ocular Surface Disorders
Kotomin, Ilya; Valtink, Monika; Hofmann, Kai; Frenzel, Annika; Morawietz, Henning; Werner, Carsten; Funk, Richard H. W.; Engelmann, Katrin
2015-01-01
Amniotic membrane is applied to the diseased ocular surface to stimulate wound healing and tissue repair, because it releases supportive growth factors and cytokines. These effects fade within about a week after application, necessitating repeated application. Generally, amniotic membrane is fixed with sutures to the ocular surface, but surgical intervention at the inflamed or diseased site can be detrimental. Therefore, we have developed a system for the mounting of amniotic membrane between two rings for application to a diseased ocular surface without surgical intervention (sutureless amniotic membrane transplantation). With this system, AmnioClip, amniotic membrane can be applied like a large contact lens. First prototypes were tested in an experiment on oneself for wearing comfort. The final system was tested on 7 patients in a pilot study. A possible influence of the ring system on the biological effects of amniotic membrane was analyzed by histochemistry and by analyzing the expression of vascular endothelial growth factor-A (VEGF-A), hepatocyte growth factor (HGF), fibroblast growth factor 2 (FGF 2) and pigment epithelium-derived factor (PEDF) from amniotic membranes before and after therapeutic application. The final product, AmnioClip, showed good tolerance and did not impair the biological effects of amniotic membrane. VEGF-A and PEDF mRNA was expressed in amniotic membrane after storage and mounting before transplantation, but was undetectable after a 7-day application period. Consequently, transplantation of amniotic membranes with AmnioClip provides a sutureless and hence improved therapeutic strategy for corneal surface disorders. Trial Registration ClinicalTrials.gov NCT02168790 PMID:25955359
Khodzhaev, N S; Sobolev, N P; Mushkova, I A; Izmaylova, S B; Karimova, A N
The diversity of methodological approaches and lack of pathogenetically reasonable tactics for patients with combined ocular injuries became the basis for the development and systematization of surgical rehabilitation stages of patients, in whom post-traumatic cataract is combined with post-traumatic aniridia and corneal scarring. to construct a visual rehabilitation approach to patients with post-traumatic defects of the anterior eye segment following optical-reconstructive surgery that involved implantation of an iris-lens diaphragm (ILD). We have analyzed 80 reconstructive cases with ILD implantation in patients with post-traumatic aniridia and corneal damage. These patients constituted the first study group (Group 1). We have also investigated 58 eyes with residual ametropy and stable visual function 1 year after ILD implantation before and after conducting a laser keratorefractive surgery. These patients were assigned to the second study group (Group 2). Rehabilitation approach to patients after anterior segment injuries that has been proposed allows to achieve high clinical and functional results and reduce the risk of intra- and postoperative complications. The proposed approach to patients after optical-reconstructive surgery with iris-lens diaphragm implantation followed by keratorefractive surgery is an effective method of visual rehabilitation of anterior eye segment post-traumatic defects.
Central Corneal Thickness and its Relationship to Intra-Ocular and Epidmiological Determinants.
Tayyab, Ali; Masrur, Amena; Afzal, Farooq; Iqbal, Fyza; Naseem, Kamran
2016-06-01
To measure central corneal thickness in Pakistani population and determine its relationship to intra-ocular pressure, age, gender and ethnicity. Cross-sectional observation study. Pakistan Institute of Medical Sciences, Islamabad, Pakistan, between December 2013 and February 2015. The right eyes of 1000 cases (496 males and 504 females) were recruited for this study. Inclusion criteria were Pashtun or Punjabi ethnicity, intra-ocular pressure < 22 mmHg, gonioscopically open angles, cup-disk-ratio < 0.5, and age matched normal visual fields. Cases with prior ocular surgery, contact lens use, corneal pathologies, myopia or hypermetropia > ±3.0 diopters, astigmatism of > ±1.0 diopters were excluded. Central corneal thickness was measured using a TopCon non-contact specular microscope. Intra-ocular pressure was measured using Goldmann applanation tonometer. Frequency distribution, test of significance, and regression analysis was carried out using Statistical Package for Social Sciences version 20.0. Mean age was 47.31 ±11.78 years. Ethnic composition was 51.6% (n=516) Pashtun and 48.4% (n=484) Punjabi. The mean central corneal thickness was 503.96 (±12.47) µm, while the mean intra-ocular pressure was 15.61 (±2.68) mmHg. Regression analysis showed a significant association between central corneal thickness and intra-ocular pressure (p=0.00) and age (p=0.00). A±100 µchange in central corneal thickness was associated with change in IOPof ±3.30 mmHg, whereas central corneal thickness decreased by 0.12 µm per year. No significant association could be established between central corneal thickness and ethnicity (p=0.19). Central corneal thickness of the studied races was comparable to non-Caucasians which affects intra-ocular pressure measurements, and decreases with increasing age. No relationship was observed between central corneal thickness and ethnicity or gender.
Refractive index measurement of the mouse crystalline lens using optical coherence tomography.
Chakraborty, Ranjay; Lacy, Kip D; Tan, Christopher C; Park, Han Na; Pardue, Machelle T
2014-08-01
In recent years, there has been a growing interest for using mouse models in refractive development and myopia research. The crystalline lens is a critical optical component of the mouse eye that occupies greater than 50% of the ocular space, and significant increases in thickness with age. However, changes in refractive index of the mouse crystalline lens are less known. In this study, we examined the changes in thickness and refractive index of the mouse crystalline lens for two different strains, wild-type (WT) and a nyx mutant (nob) over the course of normal visual development or after form deprivation. Refractive index and lens thickness measurements were made on ex vivo lenses using spectral domain optical coherence tomography (SD-OCT). Comparison of refractive index measurements on 5 standard ball lenses using the SD-OCT and their known refractive indices (manufacturer provided) indicated good precision (intra-class correlation coefficient, 0.998 and Bland-Altman coefficient of repeatability, 0.116) of the SD-OCT to calculate mouse lens refractive index ex vivo. During normal visual development, lens thickness increased significantly with age for three different cohorts of mice, aged 4 (average thickness from both eyes; WT: 1.78 ± 0.03, nob: 1.79 ± 0.08 mm), 10 (WT: 2.02 ± 0.05, nob: 2.01 ± 0.04 mm) and 16 weeks (WT: 2.12 ± 0.06, nob: 2.09 ± 0.06 mm, p < 0.001). Lens thickness was not significantly different between the two strains at any age (p = 0.557). For mice with normal vision, refractive index for isolated crystalline lenses in nob mice was significantly greater than WT mice (mean for all ages; WT: 1.42 ± 0.01, nob: 1.44 ± 0.001, p < 0.001). After 4 weeks of form deprivation to the right eye using a skull-mounted goggling apparatus, a thinning of the crystalline lens was observed in both right and left eyes of goggled animals compared to their naïve controls (average from both the right and the left eye) for both strains (p = 0.052). In form deprived mice, lens refractive index was significantly different between the goggled animals and non-goggled naïve controls in nob mice, but not in WT mice (p = 0.009). Both eyes of goggled nob mice had significantly greater lens refractive index (goggled, 1.49 ± 0.01; opposite, 1.47 ± 0.03) compared to their naïve controls (1.45 ± 0.02, p < 0.05). The results presented here suggest that there are genetic differences in the crystalline lens refractive index of the mouse eye, and that the lens refractive index in mice significantly increase with form deprivation. Research applications requiring precise optical measurements of the mouse eye should take these lens refractive indices into account when interpreting SD-OCT data. Published by Elsevier Ltd.
Jiang, Yongxiang; Lu, Yi
2015-01-01
Aim The aim of this study was to evaluate the long-term visual outcomes and factors affecting visual results in children undergoing secondary intraocular lens (IOL) implantation following primary congenital cataract extraction. Methods Children with congenital cataracts who underwent secondary IOL implantation for aphakia at the Eye and ENT Hospital of Fudan University between January 1, 2001, and December 31, 2007, were retrospectively reviewed. One eye was randomly selected in children with bilateral cataracts. Laterality, type of cataract (total or partial opacity), sex, age at primary and secondary surgeries, visual axis opacity (VAO), compliance with amblyopia therapy, postoperative ocular complications, refractive error, ocular alignment, and best corrected visual acuity (BCVA) at last follow-up were recorded; potential factors that might have affected the visual results were evaluated. Results Seventy-six bilateral and 34 unilateral congenital cataract cases were analyzed; the mean ages of the children were 12.70±5.06 and 12.50±2.71 years at final follow-up, the mean follow-up periods from IOL implantation were 94.93±24.22 and 109.09±18.89 months, and the mean BCVA (Log MAR) values were 0.51±0.37 and 1.05±0.46, respectively. Final BCVA after secondary IOL implantation was significantly associated with laterality, type of cataract, age at primary cataract extraction, compliance with amblyopia therapy, and refractive correction after surgery. No significant associations were found between BCVA and sex, age at secondary IOL implantation, VAO, or other ocular complications. The most common ocular complications were VAO and elevated intraocular pressure after surgery. There were no other complications, with the exception of one eye with IOL dislocation. Conclusions The results indicate that the important determinants of long-term visual outcomes in children with congenital cataracts undergoing secondary IOL implantation are laterality, cataract type, age at initial cataract extraction, compliance with amblyopia therapy, and refractive error. PMID:26230501
Ocular complications of boxing
Bianco, M; Vaiano, A; Colella, F; Coccimiglio, F; Moscetti, M; Palmieri, V; Focosi, F; Zeppilli, P; Vinger, P
2005-01-01
Objectives: To investigate the prevalence of ocular injuries in a large population of boxers over a period of 16 years, in particular, the most severe lesions that may be vision threatening. Methods: Clinical records of the medical archive of the Italian Boxing Federation were analysed. A total of 1032 boxers were examined from February 1982 to October 1998. A complete ophthalmological history was available for 956, who formed the study population (a total of 10 697 examinations). The following data were collected: age when started boxing; duration of competitive boxing career (from the date of the first bout); weight category; a thorough ocular history. The following investigations were carried out: measurement of visual acuity and visual fields, anterior segment inspection, applanation tonometry, gonioscopy, and examination of ocular fundus. Eighty age matched healthy subjects, who had never boxed, formed the control group. Results: Of the 956 boxers examined, 428 were amateur (44.8%) and 528 professional (55.2%). The median age at first examination was 23.1 (4.3) years (range 15–36). The prevalence of conjunctival, corneal, lenticular, vitreal, ocular papilla, and retinal alterations in the study population was 40.9% compared with 3.1% in the control group (p⩽0.0001). The prevalence of serious ocular findings (angle, lens, macula, and peripheral retina alterations) was 5.6% in boxers and 3.1% in controls (NS). Conclusions: Boxing does not result in a higher prevalence of severe ocular lesions than in the general population. However, the prevalence of milder lesions (in particular with regard to the conjunctiva and cornea) is noteworthy, justifying the need for adequate ophthalmological surveillance. PMID:15665199
Pan, Chen-Wei; Chen, Qin; Sheng, Xun; Li, Jun; Niu, Zhiqiang; Zhou, Hua; Wei, Tao; Yuan, Yuansheng; Zhong, Hua
2015-05-01
To determine the prevalence of myopia and ocular biometry in population-based samples of ethnic Yi and Han people living in an inland rural community in China. A random cluster sampling strategy was used to select ethnic Han and Yi adults aged 50 years or older living in Yunnan. Refractive error was determined by subjective refraction and ocular biometric parameters, including axial length (AL), anterior chamber depth (ACD), vitreous chamber depth (VCD), and lens thickness (LT), which were measured using an Echoscan. Adults of Yi ethnicity had lower prevalence of myopia (10.3% vs. 8.1%; P = 0.02) and high myopia (2.3% vs. 1.6%; P = 0.10) than their counterparts of Han ethnicity. The prevalence of myopia increased with age (P for trend < 0.05), whereas the mean AL did not differ significantly among age groups in both ethnic groups (both P for trend > 0.05). In multivariate analysis, time spent outdoors was associated with myopia (P = 0.003) and AL (P < 0.001) but not high myopia (P = 0.33). No interaction effect was detected between ethnicity and other risk factors on myopia (all P > 0.05). Adjustment for lens nuclear opacity score reduced the excess prevalence of myopia in Han ethnicity by 37.5%. There was little evidence showing that ethnic disparities existed in the prevalence and risk factors between the major and minor ethnic groups living in the same communities in rural China. The "cohort effect" on myopia observed in many other populations was not seen in this study.
Presumed post-traumatic ocular chondrosarcoma with intrathoracic metastases in a cat.
Moreira, Matheus V L; de Andrade, Maria C; Fulgêncio, Gustavo O; Langohr, Ingeborg M; Ecco, Roselene
2017-10-03
An indoor-only, 5-year-old, spayed female domestic shorthair cat presented for an ophthalmic examination of the left eye. An intraocular tumor with secondary glaucoma and blindness was diagnosed; the globe was enucleated and sent for histopathological examination. Gross examination revealed a solid white mass filling the entire vitreous space and replacing the iris and ciliary body. The lens and retina appeared to be similarly replaced by the neoplasm. Histological examination revealed a complete loss of the internal ocular structures, with a ruptured capsule as the only remnant of the lens within an extensive malignant mesenchymal neoplastic cell proliferation. The cells were polygonal, with well-defined cytoplasmic borders and abundant weakly basophilic cytoplasm, embedded within the islands of chondroid matrix. No neoplastic invasion of the sclera was apparent. The animal died 6 months after the enucleation due to respiratory distress. Gross examination revealed numerous firm, white to tan nodular masses with smooth to mildly irregular surfaces dispersed throughout the parietal pleura, thoracic surface of the diaphragm, tracheobronchial and mediastinal lymph nodes, pericardium, and lungs. On cross-section, the neoplastic nodules were solid and variably translucent, resembling hyaline cartilage. Histologically, these nodules were similar to the neoplasm identified earlier in the left globe. Metastasis of post-traumatic ocular chondrosarcoma has not yet been described in cats. This is therefore believed to be the first report of metastases of this type of neoplasm in cats. This case adds to the limited set of data on the outcome of this type of tumor. © 2017 American College of Veterinary Ophthalmologists.
Lee, Sang-Mok; Choi, Hyuk Jin; Choi, Heejin; Kim, Mee Kum; Wee, Won Ryang
2016-10-07
BACKGROUND: Though the development and fitting of scleral contact lenses are expanding steadily, there is no simple method to provide scleral metrics for scleral contact lens fitting yet. The aim of this study was to establish formulae for estimation of the axial radius of curvature (ARC) of the anterior sclera using ocular biometric parameters that can be easily obtained with conventional devices. A semi-automated stitching method and a computational analysis tool for calculating ARC were developed by using the ImageJ and MATLAB software. The ARC of all the ocular surface points were analyzed from the composite horizontal cross-sectional images of the right eyes of 24 volunteers; these measurements were obtained using anterior segment optical coherence tomography for a previous study (AS-OCT; Visante). Ocular biometric parameters were obtained from the same volunteers with slit-scanning topography and partial coherence interferometry. Correlation analysis was performed between the ARC at 8 mm to the axis line (ARC[8]) and other ocular parameters (including age). With ARC obtained on several nasal and temporal points (7.0, 7.5, 8.0, 8.5, and 9.0 mm from the axis line), univariate and multivariate linear regression analyses were performed to develop a model for estimating ARC with the help of ocular biometric parameters. Axial length, spherical equivalent, and angle kappa showed correlations with temporal ARC[8] (tARC[8]; Pearson's r = 0.653, -0.579, and -0.341; P = 0.001, 0.015, and 0.015, respectively). White-to-white corneal diameter (WTW) and anterior chamber depth (ACD) showed correlation with nasal ARC[8] (nARC[8]; Pearson's r = -0.492 and -0.461; P = 0.015 and 0.023, respectively). The formulae for estimating scleral curvatures (tARC, nARC, and average ARC) were developed as a function of axial length, ACD, WTW, and distance from the axis line, with good determinant power (72 - 80 %; SPSS ver. 22.0). Angle kappa showed strong correlation with axial length (Pearson's r = -0.813, P <0.001), and the different correlation patterns of nasal and temporal ARC with axial length can be explained by the ocular surface deviation represented by angle kappa. Axial length, ACD, and WTW are useful parameters for estimating the ARC of the anterior sclera, which is important for the haptic design of scleral contact lenses. Angle kappa affects the discrepancies between the nasal and temporal scleral curvature.
[Randomly sampling survey of dry eye awareness in general eye clinic].
Qiu, Wei-qiang; Liu, Zi-yuan; Ji, Jing; Zeng, Lin; Li, Xue-min; Wang, Wei
2013-03-01
To determine the dry eye awareness in the populations visiting general eye clinic. This was a cross-sectional study. A questionnaire about dry eye was designed and administrated to Peking University Third Hospital General Eye Clinic patients (n = 804) from June 2010 to June 2011. The questionnaire contents included general demographic characteristics, experience of health-related work, past medical history, medication history and ocular surface symptoms associated with dry eye, contact lens wearing, ocular operation history, etc. Chi-square and Binary logistic regression analysis was used to determine the influence of demographic and clinical features on awareness of dry eye. Awareness of "dry eye" in the general eye clinical patients was relatively low (26.9%, 216/804). Participants whose age were between 40 and 60 years had better dry eye awareness (41.7%, 73/175) (χ(2) = 27.365, P = 0.000). Dry eye awareness of female was better than that of male [female: 33.8% (151/447), male: 18.2% (65/357), χ(2) = 24.500, P = 0.000]. Those who had been in health-related work (71.4%, 30/42), and whose friends or relatives were ophthalmologists (54.7%, 52/95) had better dry eye awareness (χ(2) = 31.582, 36.400; both P < 0.01). Participants with a history of rheumatoid arthritis (7/10) or diabetes mellitus (63.0%, 17/27) had better dry eye awareness (χ(2) = 32.301, 29.887;both P < 0.01). Those who had been using artificial tears (77.5%, 31/40), oral contraceptives (9/14), diuretics (10/18), sedatives (70.4%, 19/27) and anti-depression drugs (4/4) had better dry eye awareness (χ(2) = 54.928, 10.154, 7.713, 26.912, 10.943; all P < 0.01). Except frequently blinking (29.5%), participants who had ocular irrigating symptoms (all > 33.0%) had better awareness than those who had not (χ(2) = 7.831 - 32.522, all P < 0.01). Those who were allergic to environment irritating factors (all > 30.0%) had better awareness (χ(2) = 5.033 - 24.564, all P < 0.01). Participants who had medical history of ocular surgery (47.2%, 34/72), experience of wearing contact lens (33.2%, 94/283), who were diagnosed as dry eye (100.0%, 45/45) and who had regular ocular examinations (31.0%, 96/310) had better awareness (χ(2) = 4.321 - 129.763, all P < 0.01). Those who had visited general practitioners (14.8%, 16/108) had lower awareness than those who went to hospital of higher level (28.7%, 200/696) (χ(2) = 9.324, P = 0.002). The result of binary logistic regression analysis showed that gender, health-related working experience, relatives or friends working as Ophthalmologists, using artificial tears, oral contraceptives and sedatives, ocular irritations or environment sensitivity, eye surgeries and wearing contact lens were factors that affected dry eye awareness (OR > 1.000, P < 0.10). Dry eye awareness in the population who visit general eye clinic is low. The knowledge of dry eye should be added to the patient education and public popularization.
NASA Astrophysics Data System (ADS)
Cantley, Justin L.; Hanlon, Justin; Chell, Erik; Lee, Choonsik; Smith, W. Clay; Bolch, Wesley E.
2013-10-01
Age-related macular degeneration is a leading cause of vision loss for the elderly population of industrialized nations. The IRay® Radiotherapy System, developed by Oraya® Therapeutics, Inc., is a stereotactic low-voltage irradiation system designed to treat the wet form of the disease. The IRay System uses three robotically positioned 100 kVp collimated photon beams to deliver an absorbed dose of up to 24 Gy to the macula. The present study uses the Monte Carlo radiation transport code MCNPX to assess absorbed dose to six non-targeted tissues within the eye—total lens, radiosensitive tissues of the lens, optic nerve, distal tip of the central retinal artery, non-targeted portion of the retina, and the ciliary body--all as a function of eye size and beam entry angle. The ocular axial length was ranged from 20 to 28 mm in 2 mm increments, with the polar entry angle of the delivery system varied from 18° to 34° in 2° increments. The resulting data showed insignificant variations in dose for all eye sizes. Slight variations in the dose to the optic nerve and the distal tip of the central retinal artery were noted as the polar beam angle changed. An increase in non-targeted retinal dose was noted as the entry angle increased, while the dose to the lens, sensitive volume of the lens, and ciliary body decreased as the treatment polar angle increased. Polar angles of 26° or greater resulted in no portion of the sensitive volume of the lens receiving an absorbed dose of 0.5 Gy or greater. All doses to non-targeted structures reported in this study were less than accepted thresholds for post-procedure complications.
A Novel Terminal Web-Like Structure in Cortical Lens Fibers: Architecture and Functional Assessment
Al-Ghoul, Kristin J.; Lindquist, Timothy P.; Kirk, Spencer S.; Donohue, Sean T.
2010-01-01
This study describes a novel cytoskeletal array in fiber cells of the ocular lens of the rat and shows its relationship to the classical terminal web of other epithelial tissues. Naive adult Sprague-Dawley rats (n=28) were utilized. F-actin, fodrin, myosin IIA and CP49 distribution was assessed in anterior and posterior polar sections. For functional analysis, lenses were cultured with or without cytochalasin-D for 3 hours, then processed for confocal microscopy or assessed by laser scan analysis along sutures. Phalloidin labeling demonstrated a dense mesh of F-actin adjacent to posterior sutural domains to a subcapsular depth of 400 μm. Anterior polar sections revealed a comparable actin structure adjacent to anterior suture branches however, it was not developed in superficial fibers. Fodrin and myosin were localized within the web-like actin apparatus. The data was used to construct a model showing that the cytoskeletal array is located within the blunt, variable-width fiber ends that abut at sutures such that the ‘terminal web’ flanks the suture on either side. Treatment with cytochalasin-D resulted in partial disassembly of the ‘terminal web’ and perturbed cellular organization. Laser scan analysis revealed that cytochalasin-D treated lenses had significantly greater focal variability than control lenses (p=0.020). We conclude that cortical fibers of rat lenses contain a bipolar structure that is structurally and compositionally analogous to classical terminal webs. The results indicate that the lens ‘terminal web’ functions to stabilize lens fiber ends at sutures thus minimizing structural disorder, which in turn, promotes the establishment and maintenance of lens transparency. PMID:20730867
Scleral Lenses in the Management of Corneal Irregularity and Ocular Surface Disease.
Shorter, Ellen; Harthan, Jennifer; Nau, Cherie B; Nau, Amy; Barr, Joseph T; Hodge, David O; Schornack, Muriel M
2017-09-29
To describe current practice patterns regarding the use of scleral lens therapy in the management of corneal irregularity and ocular surface disease among eye care providers who fit scleral lenses. The Scleral Lenses in Current Ophthalmic Practice: an Evaluation (SCOPE) study group conducted an electronic survey of eye care providers from January 15 to March 31, 2015. Respondents ranked management options for corneal irregularity in the order in which they would generally consider their use. Respondents also ranked options for the management of ocular surface disease in the order in which they would use each of the treatments. Results for each option were analyzed as percentage first-place ranking; percentage first-, second-, or third-place ranking; and mean rank score. Survey responses were obtained from 723 providers who had fit 5 or more scleral lenses. Of these respondents, 629 ranked options for management of corneal irregularity and 612 ranked options for management of ocular surface disease. Corneal rigid gas-permeable lenses were the first option for management of corneal irregularity for 44% of respondents, and scleral lenses were the first option for 34% of respondents. Lubricant drops were the first therapeutic recommendation for ocular surface disease for 84% of respondents, and scleral lenses were ranked first by 6% of respondents. Scleral lenses rank second only to corneal rigid gas-permeable lenses for management of corneal irregularity. Scleral lenses are generally considered after other medical intervention and before surgery for the management of ocular surface disease.
Bilateral phacoemulsification and intraocular lens implantation in a great horned owl.
Carter, Renee T; Murphy, Christopher J; Stuhr, Charles M; Diehl, Kathryn A
2007-02-15
A great horned owl of estimated age < 1 year that was captured by wildlife rehabilitators was evaluated because of suspected cataracts. Nuclear and incomplete cortical cataracts were evident in both eyes. Ocular ultrasonography revealed no evidence of retinal detachment, and electroretinography revealed normal retinal function. For visual rehabilitation, cataract surgery was planned and intraocular lens design was determined on the basis of values obtained from the schematic eye, which is a mathematical model representing a normal eye for a species. Cataract surgery and intraocular lens placement were performed in both eyes. After surgery, refraction was within -0.75 diopters in the right eye and -0.25 diopters in the left eye. Visual rehabilitation was evident on the basis of improved tracking and feeding behavior, and the owl was eventually released into the wild. In raptors with substantial visual compromise, euthanasia or placement in a teaching facility is a typical outcome because release of such a bird is unacceptable. Successful intraocular lens implantation for visual rehabilitation and successful release into the wild are achievable.
Correlation between ocular parameters and amplitude of accommodation
Abraham, Lekha Mary; Kuriakose, Thomas; Sivanandam, Viswanathan; Venkatesan, Nithya; Thomas, Ravi; Muliyil, Jayaprakash
2010-01-01
Aim: To study the relationship between ocular parameters and amplitude of accommodation (AA) in the peri-presbyopic age group (35–50 years). Materials and Methods: Three hundred and sixteen right eyes of consecutive patients in the age group 35–50 years, who attended our outpatient clinic, were studied. Emmetropes, hypermetropes and myopes with best-corrected visual acuity of 20/20, J1 in both eyes were included. The AA was calculated by measuring the near point of accommodation. The axial length (AL), central anterior chamber depth (CACD) and lens thickness (LT) were also measured. Results: There was moderate correlation (Pearson’s correlation coefficient r = 0.56) between AL and AA as well as between CACD and AA (r = 0.53) in myopes in the age group 35–39 years. In the other age groups and the groups taken as a whole, there was no correlation. In hypermetropes and emmetropes, there was no correlation between AA and the above ocular parameters. No significant correlation existed between LT and AA across different age groups and refractive errors. Conclusion: There was no significant correlation between AA and ocular parameters like anterior chamber depth, AL and LT. PMID:20952831
Large variations in ocular dimensions in a multiethnic population with similar genetic background.
Niu, Zhiqiang; Li, Jun; Zhong, Hua; Yuan, Zhonghua; Zhou, Hua; Zhang, Yang; Yuan, Yuansheng; Chen, Qin; Pan, Chen-Wei
2016-03-07
We aimed to describe the ethnic variations in ocular dimensions among three ethnic groups with similar genetic ancestry from mainland of China. We included 2119 ethnic Bai, 2202 ethnic Yi and 2183 ethnic Han adults aged 50 years or older in the study. Ocular dimensions including axial length (AL), anterior chamber depth (ACD), vitreous chamber depth (VCD) and lens thickness (LT) were measured using A-scan ultrasonography. Bai Chinese had longer ALs (P < 0.001), deeper ACDs (P < 0.001) but shallower VCDs (P < 0.001) compared with the other two ethnic groups. There were no ethnic variations in LTs. Diabetes was associated with shallower ACDs and this association was stronger in Bai Chinese compared with Yi or Han Chinese (P for interaction = 0.02). Thicker lenses were associated with younger age (P = 0.04), male gender (P < 0.001), smoking history (P = 0.01), alcohol intake (P = 0.03), the presence of cataract (P < 0.001), and the presence of diabetes (P < 0.001). There were significant differences in ocular dimensions among different ethnic groups with small differences in genetics but large variations in cultures and lifestyles.
[Rapid imaging in orbito-ocular pathology. Contribution of gadolinium].
Pigeau, I; Legeais, J M; D'Hermies, F; Fayet, B; Leport, M; Abenhaim, A; Guinet, C; Levy, C; Renard, G; Vadrot, D
1990-01-01
To evaluate Gradient-Echo Imaging (GEI) in orbito-ocular pathology, 15 volunteers and 34 patients (40 lesions) were examined with GEA T1 and GEA T2 (0.5 T). Results were compared with SE T1 in all cases, with SE T2 in 20 cases and with other imaging modalities (CT). 30 patients were examined before and after injection of gadolinium. Final diagnosis was obtained by surgery or biopsy in 24 cases or by combined results of imaging and clinical findings in 16 cases. Compared with SE, GEA demonstrated a better visualisation of optic nerve, orbital muscles, choroidal-retinal layer, lens capsule and episclera and a better detection of small lesions. It is very helpful for characterisation of lesions containing hemorrhages or paramagnetic components (melanine, gadolinium) or of vascular nature (angioma). Gadolinium was useful for detection of small lesions or characterisation of a few lesions. Thus GEA seems to be an efficient method for the evaluation of orbito-ocular pathology.
Schor, Clifton M; Bharadwaj, Shrikant R; Burns, Christopher D
2007-07-01
A dynamic model of ocular accommodation is used to simulate the stability and dynamic performance of accommodating intraocular lenses (A-IOLs) that replace the hardened natural ocular lens that is unable to change focus. Accommodation simulations of an older eye with A-IOL materials having biomechanical properties of a younger eye illustrate overshoots and oscillations resulting from decreased visco-elasticity of the A-IOL. Stable dynamics of an A-IOL are restored by adaptation of phasic and tonic neural-control properties of accommodation. Simulations indicate that neural control must be recalibrated to avoid unstable dynamic accommodation with A-IOLs. An interactive web-model of A-IOL illustrating these properties is available at http://schorlab.berkeley.edu.
Selective breeding for susceptibility to myopia reveals a gene-environment interaction.
Chen, Yen-Po; Hocking, Paul M; Wang, Ling; Povazay, Boris; Prashar, Ankush; To, Chi-Ho; Erichsen, Jonathan T; Feldkaemper, Marita; Hofer, Bernd; Drexler, Wolfgang; Schaeffel, Frank; Guggenheim, Jeremy A
2011-06-08
Purpose. To test whether the interanimal variability in susceptibility to visually induced myopia is genetically determined. Methods. Monocular deprivation of sharp vision (DSV) was induced in outbred White Leghorn chicks aged 4 days. After 4 days' DSV, myopia susceptibility was quantified by the relative changes in axial length and refraction. Chicks in the extreme tails of the distribution of susceptibility to DSV were kept and paired for breeding (high- and low-susceptibility lines). A second round of selection was then performed. The third generation of chicks, derived from the selected parents, was assessed after either monocular DSV (4 or 10 days) or lens wear. Results. After two rounds of selective breeding, the chicks from the high-susceptibility line developed approximately twice as much myopia in response to 4 days' DSV as did those from the low-susceptibility line (P < 0.001). All ocular component dimensions differed significantly (P < 0.001) between the two selected lines, both before treatment and in the responses of the treated eye. When DSV was conducted for 10 days, the relative changes in axial length and refractive error were still significantly different between the high and low lines (P < 0.001). The chicks bred for high or low susceptibility to DSV also showed significantly different responses to minus lens wear, but not to plus lens wear. Additive genetic effects explained ∼50% of the interanimal variability in response to DSV. Conclusions. Genes and environment interact to shape refractive development in chicks.
Collery, Ross F.; Veth, Kerry N.; Dubis, Adam M.; Carroll, Joseph; Link, Brian A.
2014-01-01
Refractive errors in vision can be caused by aberrant axial length of the eye, irregular corneal shape, or lens abnormalities. Causes of eye length overgrowth include multiple genetic loci, and visual parameters. We evaluate zebrafish as a potential animal model for studies of the genetic, cellular, and signaling basis of emmetropization and myopia. Axial length and other eye dimensions of zebrafish were measured using spectral domain-optical coherence tomography (SD-OCT). We used ocular lens and body metrics to normalize and compare eye size and relative refractive error (difference between observed retinal radial length and controls) in wild-type and lrp2 zebrafish. Zebrafish were dark-reared to assess effects of visual deprivation on eye size. Two relative measurements, ocular axial length to body length and axial length to lens diameter, were found to accurately normalize comparisons of eye sizes between different sized fish (R2 = 0.9548, R2 = 0.9921). Ray-traced focal lengths of wild-type zebrafish lenses were equal to their retinal radii, while lrp2 eyes had longer retinal radii than focal lengths. Both genetic mutation (lrp2) and environmental manipulation (dark-rearing) caused elongated eye axes. lrp2 mutants had relative refractive errors of −0.327 compared to wild-types, and dark-reared wild-type fish had relative refractive errors of −0.132 compared to light-reared siblings. Therefore, zebrafish eye anatomy (axial length, lens radius, retinal radius) can be rapidly and accurately measured by SD-OCT, facilitating longitudinal studies of regulated eye growth and emmetropization. Specifically, genes homologous to human myopia candidates may be modified, inactivated or overexpressed in zebrafish, and myopia-sensitizing conditions used to probe gene-environment interactions. Our studies provide foundation for such investigations into genetic contributions that control eye size and impact refractive errors. PMID:25334040
Risk factors for interruption to soft contact lens wear in children and young adults.
Wagner, Heidi; Chalmers, Robin L; Mitchell, G Lynn; Jansen, Meredith E; Kinoshita, Beth T; Lam, Dawn Y; McMahon, Timothy T; Richdale, Kathryn; Sorbara, Luigina
2011-08-01
The purpose of this study was to describe age and other risk factors for ocular events that interrupt soft contact lens (SCL) wear in youth. A retrospective chart review of SCL wearers aged 8 to 33 years at the first observed visit was conducted at six academic eye care centers in North America. Data were extracted from all visits during the observation period (>3 years). Clinical records that documented conditions resulting in an interruption of SCL wear "events" were scanned, masked for age and SCL parameters, and then adjudicated to consensus diagnosis. Generalized estimating equations were used to examine the effect of selected covariates, including age, on the risk of an event. Chart review of 3549 SCL wearers yielded 522 events among 426 wearers (12%). The risk of an event increased from ages 8 to 18 years, showed modest increases between ages 19 and 25 years, and then began to decline after age 25 years. New lens wearers (<1 year) were less likely to experience events (p = 0.001). Lens replacement schedule and material were also predictive of interruptions to SCL wear with the lowest risk in daily replacement and hydrogel lens wearers (both p < 0.0001). These results suggest that the risk of events that interrupt SCL wear peaks in late adolescence and early adulthood and reflects risk factors identified in prospective contact lens studies. Relative to older teens and young adults, patients younger than 14 years presented with significantly fewer events resulting in interrupted lens wear.
Growth regulation of the mammalian ocular lens by vitreous humor.
Banerjee, A; Parafina, J; Bagchi, M
1992-05-01
Experiments were performed in our laboratory to study the effects of a mammalian 8 kD vitreous humor (VH) factor on the DNA synthesis and mitosis of the epithelial cells of organ cultured rabbit lens. The 8 kD polypeptide factor was purified from mature rabbit vitreous humor by liquid chromatography. Proliferative activities of the epithelial cells of organ cultured lenses were stimulated by 3% rabbit serum. The data from our experiments depicted that the 8 kD VH factor effectively inhibits DNA synthesis and mitosis by the epithelial cells of the organ cultured lens. Our experiments also showed that this 8 kD VH factor can maintain its growth inhibitory activity even when heated for 3 min at 95 degrees C. The growth inhibitory effect of the 8 kD VH factor was dose dependent. Using iodinated vitreal proteins it was demonstrated that the VH proteins are able to enter or bind to lens epithelial cells. The growth inhibitory effect of the 8 kD VH factor was also tested on tissue cultured lens epithelial cells. These experiments showed that the 8 kD VH factor has no growth inhibitory effect on the tissue cultured lens epithelial cells. This experiment has been repeated many times using different concentrations of the factor. These observations suggest that the 8 kD VH factor may have receptors in the lens capsular material (extracellular matrix) and the factor-receptor binding is essential for the growth inhibitory effect.
Qiao-Grider, Ying; Hung, Li-Fang; Kee, Chea-Su; Ramamirtham, Ramkumar; Smith, Earl L
2010-08-23
We analyzed the contribution of individual ocular components to vision-induced ametropias in 210 rhesus monkeys. The primary contribution to refractive-error development came from vitreous chamber depth; a minor contribution from corneal power was also detected. However, there was no systematic relationship between refractive error and anterior chamber depth or between refractive error and any crystalline lens parameter. Our results are in good agreement with previous studies in humans, suggesting that the refractive errors commonly observed in humans are created by vision-dependent mechanisms that are similar to those operating in monkeys. This concordance emphasizes the applicability of rhesus monkeys in refractive-error studies. Copyright 2010 Elsevier Ltd. All rights reserved.
Qiao-Grider, Ying; Hung, Li-Fang; Kee, Chea-su; Ramamirtham, Ramkumar; Smith, Earl L.
2010-01-01
We analyzed the contribution of individual ocular components to vision-induced ametropias in 210 rhesus monkeys. The primary contribution to refractive-error development came from vitreous chamber depth; a minor contribution from corneal power was also detected. However, there was no systematic relationship between refractive error and anterior chamber depth or between refractive error and any crystalline lens parameter. Our results are in good agreement with previous studies in humans, suggesting that the refractive errors commonly observed in humans are created by vision-dependent mechanisms that are similar to those operating in monkeys. This concordance emphasizes the applicability of rhesus monkeys in refractive-error studies. PMID:20600237
2013-01-01
Background The contaminated contact lens provides Pseudomonas aeruginosa an ideal site for attachment and biofilm production. Continuous contact of the eye to the biofilm-infested lens can lead to serious ocular diseases, such as keratitis (corneal ulcers). The biofilms also prevent effective penetration of the antibiotics, which increase the chances of antibiotic resistance. Methods For this study, 22 Pseudomonas aeruginosa isolates were obtained from 36 contact lenses and 14 contact lens protective fluid samples. These isolates were tested against eight commonly used antibiotics using Kirby-Bauer disk diffusion method. The biofilm forming potential of these isolates was also evaluated using various qualitative and quantitative techniques. Finally, a relationship between biofilm formation and antibiotic resistance was also examined. Results The isolates of Pseudomonas aeruginosa tested were found resistant to most of the antibiotics tested. Qualitative and quantitative biofilm analysis revealed that most of the isolates exhibited strong biofilm production. The biofilm production was significantly higher in isolates that were multi-drug resistant (p < 0.0001). Conclusion Our study indicates that multi-drug resistant, biofilm forming Pseudomonas aeruginosa isolates are mainly involved in contact lens associated infections. This appears to be the first report from Pakistan, which analyzes both antibiotic resistance profile and biofilm forming potential of Pseudomonas aeruginosa isolates from contact lens of the patients with contact lens associated infections. PMID:24134792
Performance of Three Multipurpose Disinfecting Solutions with a Silicone Hydrogel Contact Lens
García-Porta, Nery; Rico-del-Viejo, Laura; Ferreira-Neves, Helena; Peixoto-de-Matos, Sofia C.; Queirós, Antonio; González-Méijome, José M.
2015-01-01
Purpose. To evaluate the clinical performance of a silicone hydrogel (Si-Hy) soft contact lens (CL) in combination with three different multipurpose disinfecting solutions (MPDSs). Methods. This was a prospective, randomized, single-masked, crossover, and comparative study in which 31 habitual soft CL wearers were randomly assigned to one of the three MPDSs (Synergi, COMPLETE RevitaLens, and OPTI-FREE PureMoist) for 1 month with a 1-week wash-out period between each exposure. All subjects were successfully refitted with a Si-Hy CL (Biofinity). Subjects were then scheduled for follow-up visits after 1 month of lens wear, being evaluated at 2 and 8 hours after lens insertion. Visual Analogue Scales (VAS) were used to gauge comfort rating. Results. The tarsal conjunctiva showed a significantly different degree of lid redness between the MPDSs at the 2-hour visit (P < 0.05, Kruskal-Wallis test), being lower for COMPLETE RevitaLens compared to the other two MPDSs (Mann-Whitney U test). Furthermore, a significantly different degree of lid roughness at the 8-hour visit was seen (P < 0.05, Kruskal-Wallis test), being higher for Synergi (Mann-Whitney U test). The subjective comfort was similar with the three MPDSs. Conclusion. Tarsal conjunctival response should be also considered in the context of the clinical performance of MPDs at the ocular surface. PMID:25918703
The effect of scleral search coil lens wear on the eye.
Murphy, P J; Duncan, A L; Glennie, A J; Knox, P C
2001-03-01
Scleral search coils are used to measure eye movements. A recent abstract suggests that the coil can affect the eye by decreasing visual acuity, increasing intraocular pressure, and damaging the corneal and conjunctival surface. Such findings, if repeated in all subjects, would cast doubt on the credibility of the search coil as a reliable investigative technique. The aim of this study was to reassess the effect of the scleral search coil on visual function. Six volunteer subjects were selected to undergo coil wear and baseline measurements were taken of logMAR visual acuity, non-contact tonometry, keratometry, and slit lamp examination. Four drops of 0.4% benoxinate hydrochloride were instilled before insertion of the lens by an experienced clinician. The lens then remained on the eye for 30 minutes. Measurements of the four ocular health parameters were repeated after 15 and 30 minutes of lens wear. The lens was then removed and the health of the eye reassessed. No obvious pattern of change was found in logMAR visual acuity, keratometry, or intraocular pressure. The lens did produce changes to the conjunctival and corneal surfaces, but this was not considered clinically significant. Search coils do not appear to cause any significant effects on visual function. However, thorough prescreening of subjects and post-wear checks should be carried out on all coil wearers to ensure no adverse effects have been caused.
Wei, Cynthia; Zhu, Meifang; Petroll, W. Matthew; Robertson, Danielle M.
2014-01-01
Purpose. To establish a rabbit model of infectious Pseudomonas aeruginosa keratitis using ultrahigh oxygen transmissible rigid lenses and characterize the frequency and severity of infection when compared to a non–oxygen transmissible lens material. Methods. Rabbits were fit with rigid lenses composed of ultrahigh and non–oxygen transmissible materials. Prior to wear, lenses were inoculated with an invasive corneal isolate of P. aeruginosa stably conjugated to green fluorescent protein (GFP). Corneas were examined before and after lens wear using a modified Heidelberg Rostock Tomograph in vivo confocal microscope. Viable bacteria adherent to unworn and worn lenses were assessed by standard plate counts. The presence of P. aeruginosa-GFP and myeloperoxidase-labeled neutrophils in infected corneal tissue was evaluated using laser scanning confocal microscopy. Results. The frequency and severity of infectious keratitis was significantly greater with inoculated ultrahigh oxygen transmissible lenses. Infection severity was associated with increasing neutrophil infiltration and in severe cases, corneal melting. In vivo confocal microscopic analysis of control corneas following lens wear confirmed that hypoxic lens wear was associated with mechanical surface damage, whereas no ocular surface damage was evident in the high-oxygen lens group. Conclusions. These data indicate that in the absence of adequate tear clearance, the presence of P. aeruginosa trapped under the lens overrides the protective effects of oxygen on surface epithelial cells. These findings also suggest that alternative pathophysiological mechanisms exist whereby changes under the lens in the absence of frank hypoxic damage result in P. aeruginosa infection in the otherwise healthy corneal epithelium. PMID:25125601
Ludema, Christina; Cole, Stephen R.; Poole, Charles; Smith, Jennifer S.; Schoenbach, Victor J.; Wilhelmus, Kirk R.
2014-01-01
Studies have suggested that exposure to ultraviolet (UV) light may increase risk of herpes simplex virus (HSV) recurrence. Between 1993 and 1997, the Herpetic Eye Disease Study (HEDS) randomized 703 participants with ocular HSV to receipt of acyclovir or placebo for prevention of ocular HSV recurrence. Of these, 308 HEDS participants (48% female and 85% white; median age, 49 years) were included in a nested study of exposures thought to cause recurrence and were followed for up to 15 months. We matched weekly UV index values from the National Oceanic and Atmospheric Administration to each participant's study center and used marginal structural Cox models to account for time-varying psychological stress and contact lens use and selection bias from dropout. There were 44 recurrences of ocular HSV, yielding an incidence of 4.3 events per 1,000 person-weeks. Weighted hazard ratios comparing persons with ≥8 hours of time outdoors to those with less exposure were 0.84 (95% confidence interval (CI): 0.27, 2.63) and 3.10 (95% CI: 1.14, 8.48) for weeks with a UV index of <4 and ≥4, respectively (ratio of hazard ratios = 3.68, 95% CI: 0.43, 31.4). Though results were imprecise, when the UV index was higher (i.e., ≥4), spending 8 or more hours per week outdoors was associated with increased risk of ocular HSV recurrence. PMID:24142918
Ocular consequences of bottle rocket injuries in children and adolescents.
Khan, Mehnaz; Reichstein, David; M Recchia, Franco
2011-05-01
To describe the spectrum of ocular injuries and associated visual morbidity in the pediatric and adolescent population caused by bottle rockets. Retrospective review of consecutive medical records of patients 18 years or younger seen during a recent 4-year period. Outcome measures were ocular injuries at time of visit, interventions required, visual acuity at most recent follow-up, and most recent anatomic findings. Eleven eyes from 10 patients (8 boys and 2 girls aged 5-17 years) were identified. Significant ocular injuries included corneal epithelial defect (7 eyes), hyphema (6 eyes), traumatic iritis (2 eyes), iridodialysis (4 eyes), cataract (4 eyes), retinal dialysis (1 eye), and vitreous hemorrhage (2 eyes). Eight eyes required primary intervention (lensectomy in 4 eyes, corneal debridement in 2 eyes, globe exploration in 1 eye, and retinal laser photocoagulation in 1 eye). Three patients required additional procedures. These secondary interventions included pars plana vitrectomy (1 eye), muscle surgery for sensory strabismus (1 eye), corneal debridement (1 eye), and intraocular lens placement (1 eye). Most recent visual acuity (10 eyes with follow-up) was 20/30 or better in 4 eyes and 20/200 or worse in 6 eyes (for 1 eye, the patient was unavailable for follow-up). Permanent visual impairment was typically due to traumatic maculopathy. Bottle rockets can cause significant ocular injury in children, often with permanent loss of vision.
The ocular complications of boxing.
Giovinazzo, V J; Yannuzzi, L A; Sorenson, J A; Delrowe, D J; Cambell, E A
1987-06-01
In cooperation with the New York State Athletic Commission, 74 boxers applying for a new or yearly renewal license were sequentially referred over a 2-year period for a complete dilated ocular examination at the Sports Vision Institute of the Manhattan Eye, Ear and Throat Hospital. At least one ocular injury was found in 66% of boxers. Vision-threatening injuries, defined as significant damage to the angle, lens, macula, or peripheral retina occurred in 58% of boxers. Nineteen percent of boxers had angle abnormalities. Nineteen percent of boxers had pathologic cataracts, over 70% of these were posterior subcapsular. Six boxers had macular lesions. A total of 24% of boxers had retinal tears. Standardized photographs were used to distinguish pathologic cataracts from congenital opacities and pathologic retinal tears from atrophic holes. Attempts were made to identify risk factors in boxing that might be predictive for ocular injury. Variables included age, weight division, left- or right-handedness, total number of losses, and total number of bouts. Significant correlations were found between the total number of bouts and the total number of losses, and the presence of retinal tears. College varsity athletes were selected as controls. Significant differences were found between boxers and controls for the total number of injuries, total vision-threatening injuries, and the number of retinal tears. A series of recommendations are proposed to aide in the early detection and prevention of serious ocular injuries.
Ultrasonographic anatomy of the bovine eye.
Potter, Timothy J; Hallowell, Gayle D; Bowen, I Mark
2008-01-01
The purposes of the study were to describe the ultrasonographic appearance and measurements of the normal bovine eye, to compare the measurements to those reported previously for cadaveric eyes and to describe differences between ocular dimensions of Holstein Friesian and Jersey cattle. Sixty transpalpebral ocular ultrasonographic examinations were performed on 30 adult Holstein Friesian cows, and 16 examinations were performed on 8 adult Jersey cows. Transpalpebral ultrasonographic images were obtained with a 10 MHz linear transducer in both horizontal and vertical imaging planes. The ultrasonographic appearance of structures within the bovine eye is similar to that in other species, although the ciliary artery was frequently identified, appearing as a 0.33 +/- 0.04 cm diameter hypoechoic area. The axial length of the globe was significantly greater in Holstein Friesian cattle (3.46 +/- 0.09 cm) compared with Jersey cattle (3.27 +/- 0.19 cm; P = 0.001), although the vitreous depth was smaller in Holstein Friesian cattle (1.46 +/- 0.09 cm) (P = 0.0009). The anterioposterior depth of the lens was significantly greater in Jersey cattle (1.92 +/- 0.11 cm) and the cornea was thinner in Jersey cattle (0.17 +/- 0.02 cm). The appearance and ocular distances for live animals were similar to those reported previously for cadaveric specimens. The knowledge of normal ocular dimensions facilitates the use of ultrasonography in the evaluation of ocular disease in cattle.
Association Between Contact Lens Discomfort and Pre-lens Tear Film Kinetics.
Guillon, Michel; Dumbleton, Kathryn A; Theodoratos, Panagiotis; Wong, Stephanie; Patel, Kishan; Banks, Gaidig; Patel, Trisha
2016-08-01
The relationship between contact lens wettability and comfort has been extensively evaluated; however, a direct correlation between the characteristics of the pre-lens tear film and the symptoms associated with contact lens discomfort has yet to be established. In addition, there is relatively limited knowledge relating to the entire tear film kinetics during the inter-blink period in contact lens wearers. The purpose of this analysis was to identify the characteristics of the pre-lens tear film kinetics that may be associated with the symptoms of contact lens discomfort. The study population comprised 202 soft (hydrogel and silicone hydrogel) contact lens wearers attending pre-screening visits at the OTG-i research clinic. All participants completed the Ocular Surface Disease Index (OSDI) questionnaire and the tear film was quantified via post hoc, masked analysis of high definition digital Tearscope videos recorded at the visit. The tear film kinetics of the least symptomatic wearers (OSDI lowest quintile scores, n = 45) were compared to the tear film kinetics of the most symptomatic wearers (OSDI highest quintile scores, n = 43). The hypothesis tested was that the tear film kinetics of asymptomatic wearers were better than tear film kinetics of symptomatic wearers. The distribution of lens types worn was as follows: Daily Disposable 46.5%, 1-Month Replacement 39.6%, and 2-Week Replacement 13.6%. 48.2% of lenses were silicone hydrogel and 51.8% hydrogel. Symptomatic wearers had a shorter break-up time (4.7 s vs. 6.0 s; p = 0.003), lesser surface coverage by the tear film during the interblink period (95.1% vs. 98.5%; p < 0.001) and greater surface exposure at the time of the blink (9.4% vs. 3.9%; p = 0.001). The current study demonstrated that the tear film kinetics of asymptomatic and symptomatic contact lens wearers were different, the findings supporting the hypothesis of poorer tear film kinetics for symptomatic than asymptomatic wearers in a general contact lens wearing population.
Risk factors for contact lens bacterial contamination during continuous wear.
Szczotka-Flynn, Loretta B; Bajaksouzian, Saralee; Jacobs, Michael R; Rimm, Alfred
2009-11-01
Microbial contamination of contact lenses is associated with corneal infection and inflammation. This study determined the microbiological, clinical, and demographic factors that are associated with bacterial contamination of a silicone hydrogel contact lens when worn for continuous wear (CW). Two hundred five healthy subjects were enrolled in the Longitudinal Analysis of Silicone Hydrogel Contact Lens Study and were fitted with lotrafilcon A lenses for monthly CW and followed for 1 year. Lenses were aseptically removed after 1 week and 4 months of wear and cultured using an agar sandwich technique. Lids and conjunctiva were routinely cultured at baseline and after 1 week and 4 months of CW. Lenses and ocular sites were considered to have substantial microbial bioburden when they harbored pathogenic organisms or high levels of commensal organisms. Univariate and multivariate logistic regression analyses were conducted to examine whether substantial conjunctival or lid bioburden, subject demographics, lens-wearing history, symptoms, and biomicroscopic signs were associated with lens bioburden. About one third (32.4%) of subjects had substantial bacterial bioburden in either eye across multiple visits. Over half (53.2%) and about one tenth (11.7%) of subjects had substantial lid and conjunctival bioburden, respectively, and 11.2% discontinued because of discomfort. The adjusted odds ratios (and 95% confidence intervals) for presence of substantial lens bioburden were 2.49 (1.17-5.30), 4.24 (1.45-12.40), and 4.11 (1.17-14.46) for substantial lid bioburden, substantial conjunctival bioburden, and lens discomfort, respectively. Bacterial contamination of silicone hydrogel contact lenses is common during CW. Substantial lens bioburden is associated with discomfort precluding successful CW. The presence of substantial lid and conjunctival bioburden is associated with a 2.5-fold and more than fourfold greater risk of substantial lens bioburden and is likely the major route of contamination.
A medieval fallacy: the crystalline lens in the center of the eye.
Leffler, Christopher T; Hadi, Tamer M; Udupa, Akrithi; Schwartz, Stephen G; Schwartz, Daniel
2016-01-01
To determine whether, as most modern historians have written, ancient Greco-Roman authors believed the crystalline lens is positioned in the center of the eye. Historians have written that statements about cataract couching by Celsus, or perhaps Galen of Pergamon, suggested a centrally located lens. Celsus specifically wrote that a couching needle placed intermediate between the corneal limbus and the lateral canthus enters an empty space, presumed to represent the posterior chamber. Ancient ophthalmic literature was analyzed to understand where these authors believed the crystalline lens was positioned. In order to estimate where Celsus proposed entering the eye during couching, we prospectively measured the distance from the temporal corneal limbus to the lateral canthus in 30 healthy adults. Rufus of Ephesus and Galen wrote that the lens is anterior enough to contact the iris. Galen wrote that the lens equator joins other ocular structures at the corneoscleral junction. In 30 subjects, half the distance from the temporal corneal limbus to the lateral canthus was a mean of 4.5 mm (range: 3.3-5.3 mm). Descriptions of couching by Celsus and others are consistent with pars plana entry of the couching needle. Anterior angulation of the needle would permit contact of the needle with the lens. Ancient descriptions of anatomy and couching do not establish the microanatomic relationships of the ciliary region with any modern degree of accuracy. Nonetheless, ancient authors, such as Galen and Rufus, clearly understood that the lens is located anteriorly. There is little reason to believe that Celsus or other ancient authors held a variant understanding of the anatomy of a healthy eye. The notion of the central location of the lens seems to have arisen with Arabic authors in 9th century Mesopotamia, and lasted for over 7 centuries.
Hägglund, Anna-Carin; Jones, Iwan
2017-01-01
ABSTRACT Development of the cornea, lens, ciliary body and iris within the anterior segment of the eye involves coordinated interaction between cells originating from the ciliary margin of the optic cup, the overlying periocular mesenchyme and the lens epithelium. Anterior segment dysgenesis (ASD) encompasses a spectrum of developmental syndromes that affect these anterior segment tissues. ASD conditions arise as a result of dominantly inherited genetic mutations and result in both ocular-specific and systemic forms of dysgenesis that are best exemplified by aniridia and Axenfeld–Rieger syndrome, respectively. Extensive clinical overlap in disease presentation amongst ASD syndromes creates challenges for correct diagnosis and classification. The use of animal models has therefore proved to be a robust approach for unravelling this complex genotypic and phenotypic heterogeneity. However, despite these successes, it is clear that additional genes that underlie several ASD syndromes remain unidentified. Here, we report the characterisation of a novel mouse model of ASD. Conditional deletion of Tsc1 during eye development leads to a premature upregulation of mTORC1 activity within the ciliary margin, periocular mesenchyme and lens epithelium. This aberrant mTORC1 signalling within the ciliary margin in particular leads to a reduction in the number of cells that express Pax6, Bmp4 and Msx1. Sustained mTORC1 signalling also induces a decrease in ciliary margin progenitor cell proliferation and a consequent failure of ciliary body and iris development in postnatal animals. Our study therefore identifies Tsc1 as a novel candidate ASD gene. Furthermore, the Tsc1-ablated mouse model also provides a valuable resource for future studies concerning the molecular mechanisms underlying ASD and acts as a platform for evaluating therapeutic approaches for the treatment of visual disorders. PMID:28250050
[Role of community pharmacist in the management of patients in ophthalmology].
Delolme, M-P; Law-Ki, A; Belon, J-P; Creuzot-Garcher, C; Bron, A
2011-03-01
To assess the role of community pharmacists in ophthalmology, to evaluate the frequency of giving patients advice, and to report their difficulties in daily practice. An anonymous questionnaire consisting of 13 questions was sent to 620 community pharmacists of Burgundy (France). Pharmacists were asked about their ophthalmic products, their ophthalmic activity in giving patients advice on ocular symptoms, and patients' expectations. For analysis, community pharmacies were separated into three groups: pharmacies in rural areas (under 2000 inhabitants), pharmacies in an urban zone with fewer than 10,000 inhabitants, and pharmacies in an urban zone with more than 10,000 inhabitants. The response rate was 46.9%. Ophthalmic products were mainly glasses for presbyopia (84.5%), eye care hygiene products (76.0%), and contact lens solutions (55.3%). Ophthalmic vitamin supplements were sold by 36.8% of pharmacists, mainly in urban areas. On average, the pharmacist was consulted for ocular problems seven times a week. Acute benign symptoms were most frequent. Advice on prescriptions came next. Then, information on contact lenses and chronic ocular disease were given (cataract, glaucoma, visual acuity loss, age-related maculopathy). Finally, the pharmacist either sold the patient an ocular treatment or oriented the patient to an ophthalmologist when needed. The pharmacist and his staff are active players in providing advice on ocular diseases and taking care of patients. Moreover, pharmacists have to manage ocular therapeutics, urgent symptoms, and chronic diseases. However, in our study, 46.0% of pharmacists felt confident with their knowledge on ophthalmology, 36.4% did not give their opinion, and 7.0% were uncomfortable with some questions. Most community pharmacists mentioned a lack of continuing education from pharmaceutical companies and postgraduate education on ocular diseases and treatment, mainly for age-related maculopathy. Copyright © 2010 Elsevier Masson SAS. All rights reserved.
NASA Astrophysics Data System (ADS)
Lin, Shan-Yang; Chen, Ko-Hwa; Lin, Chih-Cheng; Cheng, Wen-Ting; Li, Mei-Jane
2010-10-01
This preliminary report was attempted to compare the chemical components of mineral deposits on the surfaces of an opacified intraocular lens (IOL) and a calcified senile cataractous lens (SCL) by vibrational spectral diagnosis. An opacified intraocular lens (IOL) was obtained from a 65-year-old male patient who had a significant decrease in visual acuity 2-years after an ocular IOL implantation. Another SCL with grayish white calcified plaque on the subcapsular cortex was isolated from a 79-year-old male patient with complicated cataract after cataract surgery. Optical light microscope was used to observe both samples and gross pictures were taken. Fourier transform infrared (FT-IR) and Raman microspectroscopic techniques were employed to analyze the calcified deposits. The curve-fitting algorithm using the Gaussian function was also used to quantitatively estimate the chemical components in each deposit. The preliminary results of spectral diagnosis indicate that the opacified IOL mainly consisted of the poorly crystalline, immature non-stoichiometric hydroxyapatite (HA) with higher content of type B carbonated apatites. However, the calcified plaque deposited on the SCL was comprised of a mature crystalline stoichiometric HA having higher contents of type A and type B carbonate apatites. More case studies should be examined in future.
Ocular higher-order aberrations in a school children population.
Papamastorakis, George; Panagopoulou, Sophia; Tsilimbaris, Militadis K; Pallikaris, Ioannis G; Plainis, Sotiris
2015-01-01
The primary objective of the study was to explore the statistics of ocular higher-order aberrations in a population of primary and secondary school children. A sample of 557 children aged 10-15 years were selected from two primary and two secondary schools in Heraklion, Greece. Children were classified by age in three subgroups: group I (10.7±0.5 years), group II (12.4±0.5 years) and group III (14.5±0.5 years). Ocular aberrations were measured using a wavefront aberrometer (COAS, AMO Wavefront Sciences, USA) at mesopic light levels (illuminance at cornea was 4lux). Wavefront analysis was achieved for a 5mm pupil. Statistical analysis was carried out for the right eye only. The average coefficient of most high-order aberrations did not differ from zero with the exception of vertical (0.076μm) and horizontal (0.018μm) coma, oblique trefoil (-0.055μm) and spherical aberration (0.018μm). The most prominent change between the three groups was observed for the spherical aberration, which increased from 0.007μm (SE 0.005) in group I to 0.011μm (SE 0.004) in group II and 0.030μm (SE 0.004) in group III. Significant differences were also found for the oblique astigmatism and the third-order coma aberrations. Differences in the low levels of ocular spherical aberration in young children possibly reflect differences in lenticular spherical aberration and relate to the gradient refractive index of the lens. The evaluation of spherical aberration at certain stages of eye growth may help to better understand the underlying mechanisms of myopia development. Copyright © 2014 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.
Ocular higher-order aberrations in a school children population
Papamastorakis, George; Panagopoulou, Sophia; Tsilimbaris, Militadis K.; Pallikaris, Ioannis G.; Plainis, Sotiris
2014-01-01
Purpose The primary objective of the study was to explore the statistics of ocular higher-order aberrations in a population of primary and secondary school children. Methods A sample of 557 children aged 10–15 years were selected from two primary and two secondary schools in Heraklion, Greece. Children were classified by age in three subgroups: group I (10.7 ± 0.5 years), group II (12.4 ± 0.5 years) and group III (14.5 ± 0.5 years). Ocular aberrations were measured using a wavefront aberrometer (COAS, AMO Wavefront Sciences, USA) at mesopic light levels (illuminance at cornea was 4 lux). Wavefront analysis was achieved for a 5 mm pupil. Statistical analysis was carried out for the right eye only. Results The average coefficient of most high-order aberrations did not differ from zero with the exception of vertical (0.076 μm) and horizontal (0.018 μm) coma, oblique trefoil (−0.055 μm) and spherical aberration (0.018 μm). The most prominent change between the three groups was observed for the spherical aberration, which increased from 0.007 μm (SE 0.005) in group I to 0.011 μm (SE 0.004) in group II and 0.030 μm (SE 0.004) in group III. Significant differences were also found for the oblique astigmatism and the third-order coma aberrations. Conclusions Differences in the low levels of ocular spherical aberration in young children possibly reflect differences in lenticular spherical aberration and relate to the gradient refractive index of the lens. The evaluation of spherical aberration at certain stages of eye growth may help to better understand the underlying mechanisms of myopia development. PMID:25288226
Maulvi, Furqan A; Lakdawala, Dhara H; Shaikh, Anjum A; Desai, Ankita R; Choksi, Harsh H; Vaidya, Rutvi J; Ranch, Ketan M; Koli, Akshay R; Vyas, Bhavin A; Shah, Dinesh O
2016-03-28
Glaucoma is commonly treated using eye drops, which is highly inefficient due to rapid clearance (low residence time) from ocular surface. Contact lenses are ideally suited for controlled drug delivery to cornea, but incorporation of any drug loaded particulate system (formulation) affect the optical and physical property of contact lenses. The objective of the present work was to implant timolol maleate (TM) loaded ethyl cellulose nanoparticle-laden ring in hydrogel contact lenses that could provide controlled drug delivery at therapeutic rates without compromising critical lens properties. TM-implant lenses were developed, by dispersing TM encapsulated ethyl cellulose nanoparticles in acrylate hydrogel (fabricated as ring implant) and implanted the same in hydrogel contact lenses (sandwich system). The TM-ethyl cellulose nanoparticles were prepared by double emulsion method at different ratios of TM to ethyl cellulose. The X-ray diffraction studies revealed the transformation of TM to amorphous state. In vitro release kinetic data showed sustained drug release within the therapeutic window for 168h (NP 1:3 batch) with 150μg loading. Cytotoxicity and ocular irritation study demonstrated the safety of TM-implant contact lenses. In vivo pharmacokinetic studies in rabbit tear fluid showed significant increase in mean residence time (MRT) and area under curve (AUC), with TM-implant contact lenses in comparison to eye drop therapy. In vivo pharmacodynamic data in rabbit model showed sustained reduction in intra ocular pressure for 192h. The study demonstrated the promising potential of implantation technology to treat glaucoma using contact lenses, and could serve as a platform for other ocular diseases. Copyright © 2016 Elsevier B.V. All rights reserved.
The Tehran Eye Study: research design and eye examination protocol
Hashemi, Hassan; Fotouhi, Akbar; Mohammad, Kazem
2003-01-01
Background Visual impairment has a profound impact on society. The majority of visually impaired people live in developing countries, and since most disorders leading to visual impairment are preventable or curable, their control is a priority in these countries. Considering the complicated epidemiology of visual impairment and the wide variety of factors involved, region specific intervention strategies are required for every community. Therefore, providing appropriate data is one of the first steps in these communities, as it is in Iran. The objectives of this study are to describe the prevalence and causes of visual impairment in the population of Tehran city; the prevalence of refractive errors, lens opacity, ocular hypertension, and color blindness in this population, and also the familial aggregation of refractive errors, lens opacity, ocular hypertension, and color blindness within the study sample. Methods Design Through a population-based, cross-sectional study, a total of 5300 Tehran citizens will be selected from 160 clusters using a stratified cluster random sampling strategy. The eligible people will be enumerated through a door-to-door household survey in the selected clusters and will be invited. All participants will be transferred to a clinic for measurements of uncorrected, best corrected and presenting visual acuity; manifest, subjective and cycloplegic refraction; color vision test; Goldmann applanation tonometry; examination of the external eye, anterior segment, media, and fundus; and an interview about demographic characteristics and history of eye diseases, eye trauma, diabetes mellitus, high blood pressure, and ophthalmologic cares. The study design and eye examination protocol are described. Conclusion We expect that findings from the TES will show the status of visual problems and their causes in the community. This study can highlight the people who should be targeted by visual impairment prevention programs. PMID:12859794
A Novel Quantitative 500-MHz Acoustic-microscopy System for Ophthalmologic Tissues
Rohrbach, Daniel; Jakob, Anette; Lloyd, Harriet O.; Tretbar, Steffen H.; Silverman, Ronald H.; Mamou, Jonathan
2017-01-01
Objective This paper describes development of a novel 500-MHz scanning acoustic microscope (SAM) for assessing the mechanical properties of ocular tissues at fine resolution. The mechanical properties of some ocular tissues, such as lamina cribrosa (LC) in the optic nerve head, are believed to play a pivotal role in eye pathogenesis. Methods A novel etching technology was used to fabricate silicon-based lens for a 500-MHz transducer. The transducer was tested in a custom designed scanning system on human eyes. Two-dimensional (2D) maps of bulk modulus (K), mass density (ρ) were derived using improved versions of current state-of-the-art signal processing approaches. Results The transducer employed a lens radius of 125 μm and had a center frequency of 479 MHz with a −6-dB bandwidth of 264 MHz and a lateral resolution of 4 μm. The LC, Bruch’s membrane (BM) at the interface of the retina and choroid, and Bowman’s layer (BL) at the interface of the corneal epithelium and stroma, were successfully imaged and resolved. Analysis of the 2D parameter maps revealed average values of LC, BM and BL with KLC = 2.81 ± 0.17; GPa, KBM = 2.89 ± 0.18; GPa, K BL = 2.6 ± 0.09; GPa, ρ LC = 0.96 ± 0.03 g/cm3; ρ BM = 0.97 ± 0.04 g/cm3; ρ BL = 0.98 ± 0.04g/cm3; Significance This novel SAM was shown to be capable of measuring mechanical properties of soft biological tissues at microscopic resolution; it currently is the only system that allows Simultaneous measurement of K, ρ, and attenuation in large lateral scales (field area > 9 mm2) and at fine resolutions. PMID:27249824
The Tehran Eye Study: research design and eye examination protocol.
Hashemi, Hassan; Fotouhi, Akbar; Mohammad, Kazem
2003-07-15
Visual impairment has a profound impact on society. The majority of visually impaired people live in developing countries, and since most disorders leading to visual impairment are preventable or curable, their control is a priority in these countries. Considering the complicated epidemiology of visual impairment and the wide variety of factors involved, region specific intervention strategies are required for every community. Therefore, providing appropriate data is one of the first steps in these communities, as it is in Iran. The objectives of this study are to describe the prevalence and causes of visual impairment in the population of Tehran city; the prevalence of refractive errors, lens opacity, ocular hypertension, and color blindness in this population, and also the familial aggregation of refractive errors, lens opacity, ocular hypertension, and color blindness within the study sample. Through a population-based, cross-sectional study, a total of 5300 Tehran citizens will be selected from 160 clusters using a stratified cluster random sampling strategy. The eligible people will be enumerated through a door-to-door household survey in the selected clusters and will be invited. All participants will be transferred to a clinic for measurements of uncorrected, best corrected and presenting visual acuity; manifest, subjective and cycloplegic refraction; color vision test; Goldmann applanation tonometry; examination of the external eye, anterior segment, media, and fundus; and an interview about demographic characteristics and history of eye diseases, eye trauma, diabetes mellitus, high blood pressure, and ophthalmologic cares. The study design and eye examination protocol are described. We expect that findings from the TES will show the status of visual problems and their causes in the community. This study can highlight the people who should be targeted by visual impairment prevention programs.
Ocular refractive and biometric characteristics in patients with thalassaemia major.
Nowroozzadeh, Mohammad Hosein; Kalantari, Zahra; Namvar, Khadije; Meshkibaf, Mohammad Hassan
2011-07-01
Thalassaemia major is associated with characteristic findings in craniofacial bony structures and thereby may render abnormal bony orbit and subsequently distinctive ocular biometry. The purpose of the present study was to evaluate the ocular refractive and biometric characteristics in patients with thalassaemia major. This case-controlled study comprised 94 eyes of 47 patients with thalassaemia major and 88 eyes of 44 age- and sex-matched healthy control subjects. All participants had a complete ocular examination including slitlamp biomicroscopy, fundoscopy, ocular biometry, keratometry, refraction and analysis using Fourier transformation. There were no significant differences in spherical equivalent (p = 0.66) and total astigmatism (p = 0.83) between groups. Mean uncorrected vision and visual acuities (logMar) were similar (p = 0.32 and p = 0.71, respectively). Compared with controls, thalassaemic patients had a shorter axial length (23.01 ± 0.12 [SEM] mm versus 23.46 ± 0.12 mm, p = 0.035), thicker crystalline lens (4.01 ± 0.11 mm versus 3.87 ± 0.1 mm, p = 0.046) and steeper average keratometry (44.02 ± 0.24 D versus 43.44 ± 0.24, p = 0.03). Fifty-seven per cent of thalassaemic patients had against-the-rule astigmatism (total), while 64.6 per cent of controls showed a with-the-rule pattern (p < 0.05). These patterns were also found for corneal astigmatism. The magnitudes of total, corneal and lenticular astigmatism were similar among groups. Regression analysis showed significant correlation between corneal (J0 and J45) and total (J0 and J45) astigmatism. The correlations were less prominent between lenticular and total J0 and J45. The mean intraocular pressure was 14.68 ± 0.27 mmHg and 13.3 ± 0.26 mmHg in the thalassaemia and control groups, respectively (p < 0.001). Six eyes (12.8 per cent) of four patients in the thalassaemia group had posterior subcapsular cataract, while the condition had not been observed in controls (p = 0.049). Shorter axial length, thicker lens, steeper corneal curvature and more against-the-rule pattern were characteristic findings in patients with thalassaemia major. © 2011 The Authors. Clinical and Experimental Optometry © 2011 Optometrists Association Australia.
Gause, Samuel; Hsu, Kuan-Hui; Shafor, Chancellor; Dixon, Phillip; Powell, Kristin Conrad; Chauhan, Anuj
2016-07-01
Ophthalmic drug for the anterior chamber diseases are delivered into tears by either eye drops or by extended release devices placed in the eyes. The instilled drug exits the eye through various routes including tear drainage into the nose through the canaliculi and transport across various ocular membranes. Understanding the mechanisms relevant to each route can be useful in predicting the dependency of ocular bioavailability on various formulation parameters, such as drug concentration, salinity, viscosity, etc. Mathematical modeling has been developed for each of the routes and validated by comparison with experiments. The individual models can be combined into a system model to predict the fraction of the instilled drug that reaches the target. This review summarizes the individual models for the transport of drugs across the cornea and conjunctiva and the canaliculi tear drainage. It also summarizes the combined tear dynamics model that can predict the ocular bioavailability of drugs instilled as eye drops. The predictions from the individual models and the combined model are in good agreement with experimental data. Both experiments and models predict that the corneal bioavailability for drugs delivered through eye drops is less than 5% due to the small area of the cornea in comparison to the conjunctiva, and the rapid clearance of the instilled solution by tear drainage. A contact lens is a natural choice for delivering drugs to the cornea due to the placement of the contact in the immediate vicinity of the cornea. The drug released by the contact towards the cornea surface is trapped in the post lens tear film for extended duration of at least 30min allowing transport of a large portion into the cornea. The model predictions backed by in vivo animal and clinical data show that the bioavailability increases to about 50% with contact lenses. This realization has encouraged considerable research towards delivering ocular drugs by contact lenses. Commercial contacts are, however, not ideal for drug delivery due to the short release durations which may necessitate wearing multiple lenses each day, reducing the viability of this approach. Recent research has focused on designing contacts that retain all critical properties while increasing the release durations to a few hours or a few days. Beagle dog studies with contact lenses containing vitamin E nanobarriers to attenuate drug transport have shown promising results. Human studies using contacts for drug delivery have also been conducted for allergy therapy but drug eluting contacts are not available in the market for any therapy. Copyright © 2015 Elsevier B.V. All rights reserved.
Efficacy of Rebamipide Instillation for Contact Lens Discomfort With Dry Eye.
Igarashi, Tsutomu; Kobayashi, Maika; Yaguchi, Chiemi; Fujimoto, Chiaki; Suzuki, Hisaharu; Takahashi, Hiroshi
2017-11-10
To examine the effects of rebamipide ophthalmic solution on the symptoms, signs, and cytokine concentrations in tear fluid among soft contact lens (SCL) wearers with Dry eye disease (DED). From November 2015 to June 2017, this open-label, single-arm study examined 40 eyes of 20 SCL wearers with DED who had been using daily disposable SCLs for >3 months (mean age, 30.0±8.33 years; range, 20-47 years). Signs, symptoms, and cytokine concentrations were assessed before and 4 weeks after starting 2% rebamipide ophthalmic solution 4 times/day. Dry eye disease was diagnosed according to: compromised tear dynamics (Schirmer test ≤5 mm or tear break-up time (TBUT) ≤5 sec); ocular surface abnormalities (positive vital staining with fluorescein or lissamine green); and presence of symptoms. Touch thresholds using a Cochet-Bonnet anesthesiometer were also determined for the cornea and conjunctivae. Symptoms were assessed using the 12-item Ocular Surface Disease Index questionnaire. Concentrations of cytokines in tear fluid were measured. Significant improvements in signs were seen for TBUT, surface abnormalities, and touch thresholds. Ocular Surface Disease Index scores likewise improved significantly in all the 12 items. Of the cytokines measured, only interleukin-1β, interleukin-8, and monocyte chemotactic protein-1 were found in ≥60% of tear samples, with no significant differences in concentrations before and after rebamipide use. Rebamipide significantly improved all signs and symptoms in patients with DED who wore daily disposable SCLs. Rebamipide is effective for DED treatment with SCL wear.This is an open access article distributed under the Creative Commons Attribution License 4.0 (CCBY), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Ultraviolet radiation and the eye: an epidemiologic study.
Taylor, H R
1989-01-01
Circumstantial evidence from biochemical, animal, and epidemiologic studies suggests an association between exposure to UV-B radiation (290 nm to 320 nm) and cataract. Such an association had not been proven because it had not been possible to quantify ocular UV-B exposure of individuals or to reliably grade the type and severity of cataract in field studies. We undertook an epidemiologic survey of cataract among 838 watermen who work on the Chesapeake Bay. Their individual ocular UV-B exposure was quantified for each year of life over the age of 16, on the basis of a detailed occupational history combined with laboratory and field measurements of ocular UV-B exposure. Cataracts were graded by both type and severity through clinical and photographic means. SMD changes were ascertained by fundal photography. A general medical history was taken to discover potentially confounding factors. This study showed that people with cortical lens opacities had a 21% higher UV-B exposure at each year of life than people without these opacities. A doubling in lifetime UV-B exposure led to a 60% increase in the risk of cortical cataract, and those with a high annual UV-B exposure increased their risk of cortical cataract over threefold. Corneal changes, namely pterygium and CDK, were also strongly associated with high UV-B exposure. No association was found between nuclear lens opacities or macular degeneration and UV-B exposure. This study also indicated several simple, practical measures, such as wearing spectacles or a hat, that effectively protect the eye from UV-B exposure. Thus it is easily within the power of individuals to protect their eyes from excessive UV-B exposure and reduce their risk of cortical cataract. A program of public education in this area could be a cost-effective means of reducing this important disease. PMID:2562534
Shah, Ameet; Lascaratos, Gerassimos; Garway-Heath, David F; Foster, Paul J; Barton, Keith
2014-06-10
To explore changes in iris curvature over a 2-year period. To investigate associations between iris curvature and ocular biometric parameters. To explore relationships between a number of nonocular measurements and ocular biometric parameters. Schoolboys enrolled 2 years previously were invited to return for anterior segment optical coherence tomography, corneal hysteresis (CH), corneal resistance factor (CRF), and axial biometric measurements. Refractive error was assessed and measures of height, weight, waist circumference, digit ratio, and percentage body fat taken. Mean spherical equivalent refraction reduced by 0.76 diopters and mean iris concavity, defined as a measurement of less than or equal to -0.1 mm, increased by 0.018 mm at distance fixation and 0.04 mm on accommodation. Compared with 2 years previously, the prevalence of iris concavity increased from 24% to 32% on distance fixation and from 65% to 84% on accommodation. Variables significantly associated with nonaccommodating iris curvature were anterior chamber depth (ACD, P = 0.029) and mean scleral spur angle (P = 0.0001). Variables significantly associated with accommodating iris curvature were ACD (P = 0.02), lens vault (P = 0.047), and scleral spur angle (P < 0.0001). Significant association was again found between CH and accommodating spur-to-spur distance (R(2) = 0.13, P = 0.007). Iris concavity was more prevalent in this cohort of schoolboys than 2 years earlier. The degree of concavity remains related to ACD and lens vault. The association between spur-to-spur distance and CH was similar at baseline and after 2 years. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.
Ocular Risk Factors for Age-related Macular Degeneration: The Los Angeles Latino Eye Study (LALES)
Fraser-Bell, Samantha; Choudhury, Farzana; Klein, Ronald; Azen, Stanley; Varma, Rohit
2010-01-01
Purpose To assess the association of ocular factors and age-related macular degeneration (AMD) in Latinos. Design Population-based, cross-sectional study of 6357 self-identified Latinos aged 40 years and older. Methods Ophthalmic examination included subjective refraction, measurement of axial length, evaluation of iris color, Lens Opacities Classification System II (LOCS II) grading of cataracts, and stereoscopic macular photographs for AMD lesions. Generalized estimating equation analysis incorporated data from both eyes to estimate odds ratios adjusted for covariates. Results After controlling for confounders (age, gender and smoking), prior cataract surgery was associated with advanced AMD (OR: 2.8, 95% CI 1.0, 7.8), increased retinal pigment (OR: 1.6, 95% CI 1.0, 1.5) and retinal pigment epithelial depigmentation (OR: 2.2, 95% CI 1.1, 4.4). The presence of any lens opacity was associated with soft drusen (OR: 1.2; 95% CI 1.0, 1.5). Longer axial length (per mm) was associated with a decreased odds of soft drusen, increased retinal pigment, and geographic atrophy (GA) (ORs: 0.8 [95% CI 0.7, 0.9], 0.8 [95% CI 0.7, 0.9], 0.7 [95% CI 0.5, 0.9], respectively. Myopia was inversely associated with soft drusen (OR: 0.8; 95% CI 0.7, 1.0). Lighter colored irises were associated with GA (OR: 5.0; 95% CI 1.0, 25.3). Conclusions Cross-sectional associations of ocular factors such as cataract, cataract surgery, and refractive errors with early AMD lesions found in Latinos were consistent with those in whites. Additionally, prior cataract surgery was associated with advanced AMD. PMID:20138605
Major ocular trauma in Taiwan: 2002-2004 versus 2012-2014.
Chang, Yi-Sheng; Teng, Yu-Ti; Huang, Yi-Hsun; Liu, Mei-Ling; Hung, Jia-Horung; Hsu, Sheng-Min; Huang, Fu-Chin; Shih, Min-Hsiu; Chen, Wan-Ju; Lai, Chun-Chieh; Hsiao, Shu-Fang; Wang, Shih-Hao; Tseng, Sung-Huei
2018-05-04
We investigated the temporal changes in major eye injuries in Taiwan by reviewing the medical records of all patients with ocular trauma hospitalized at the National Cheng Kung University Hospital during 2002-2004 and 2012-2014. A total of 169 eyes (161 patients) during 2002-2004 and 121 eyes (120 patients) during 2012-2014 were enrolled (mean ± SD age: 41.9 ± 20.8 years in 2002-2004, and 51.8 ± 19.3 years in 2012-2014). Males accounted for ~75% of patients. The most frequent injury-causing object was metallic material (~24%), and blunt traumas were most frequently attributable to traffic accidents and falls. The most common locations of injuries for males and females were the workplace and home, respectively. Open-globe injuries occurred in ~70% of eyes, requiring primary repair, cataract extraction, and/or intraocular lens implantation. The frequencies of fall injury, lacrimal system laceration, lens injury, corneal/scleral foreign bodies, and use of intracameral antibiotics increased from 2002-2004 to 2012-2014, while those of closed-globe injury, vitreous haemorrhage, optic nerve injury, and medical treatment decreased. The final visual acuity remained poor (≤20/200) in >1/3 of injured eyes. Despite therapeutic advancements, major eye injuries still pose a high risk for poor visual outcome.
Opposite Effects of Glucagon and Insulin on Compensation for Spectacle Lenses in Chicks
Zhu, Xiaoying; Wallman, Josh
2009-01-01
Purpose Chick eyes compensate for defocus imposed by positive or negative spectacle lenses. Glucagon may signal the sign of defocus. Do insulin (or IGF-1) and glucagon act oppositely in controlling eye growth, as they do in metabolic pathways and in control of retinal neurogenesis? Methods Chicks, wearing either lenses or diffusers or neither over both eyes, were injected with glucagon, a glucagon antagonist, insulin, or IGF-1 in one eye (saline in other eye). Alternatively, chicks without lenses received insulin plus glucagon in one eye, and either glucagon or insulin in the fellow eye. Ocular dimensions, refractive errors and glycosaminoglycan synthesis were measured over 2-4 days. Results Glucagon attenuated the myopic response to negative lenses or diffusers by slowing ocular elongation and thickening the choroid; in contrast, with positive lenses, it increased ocular elongation to normal levels and reduced choroidal thickening, as did a glucagon antagonist. Insulin prevented the hyperopic response to positive lenses by speeding ocular elongation and thinning the choroid. In eyes without lenses, both insulin and IGF-1 speeded, and glucagon slowed, ocular elongation, but either glucagon or insulin increased the rate of thickening of the crystalline lens. When injected together, insulin blocked choroidal thickening by glucagon, at a dose that did not, by itself, thin the choroid. Conclusions Glucagon and insulin (or IGF-1) cause generally opposite modulations of eye-growth, with glucagon mostly increasing choroidal thickness and insulin mostly increasing ocular elongation. These effects are mutually inhibitory and depend on the visual input. PMID:18791176
Su, James; Iomdina, Elena; Tarutta, Elena; Ward, Brian; Song, Jie; Wildsoet, Christine F.
2008-01-01
There has been generally little attention paid to the utilization of biomaterials as an anti-myopia treatment. The purpose of this study was to investigate whether polymeric hydrogels, either implanted or injected adjacent to the outer scleral surface, slow ocular elongation. White Leghorn (gallus gallus domesticus) chicks were used at 2 weeks of age. Chicks had either (1) strip of poly(2-hydroxyethyl methacrylate) (pHEMA) implanted monocularly against the outer sclera at the posterior pole, or (2) an in situ polymerizing gel [main ingredient: poly(vinyl-pyrrolidone) (PVP)] injected monocularly at the same location. Some of the eyes injected with the polymer were fitted with a diffuser or a −10D lens. In each experiment, ocular lengths were measured at regular intervals by high frequency A-scan ultrasonography, and chicks were sacrificed for histology at staged intervals. No in vivo signs of either orbital or ocular inflammation were observed. The pHEMA implant significantly increased scleral thickness by the third week, and the implant became encapsulated with fibrous tissue. The PVP-injected eyes left otherwise untreated, showed a significant increase in scleral thickness, due to increased chondrocyte proliferation and extracellular matrix deposition. However, there was no effect of the PVP injection on ocular elongation. In eyes wearing optical devices, there was no effect on either scleral thickness or ocular elongation. These results represent “proof of principle” that scleral growth can be manipulated without adverse inflammatory responses. However, since neither approach slowed ocular elongation, additional factors must influence scleral surface area expansion in the avian eye. PMID:19109950
Vajpayee, R B; Angra, S K; Honavar, S G
1994-04-15
Over a period of two years we performed combined penetrating keratoplasty, cataract extraction, and intraocular lens implantation in seven children between the ages of 2 and 12 years old. The interval between trauma and the surgery varied from six weeks to six months (3.5 +/- 1.6 months, mean +/- SD). All of the patients had undergone primary repair of corneal perforation. Fresh corneas preserved in McCarey-Kaufman medium were used. The graft size was 7.5 mm with 0.5 mm disparity. Posterior chamber polymethylmethacrylate C-loop lenses were used in all cases. The surgeon's average postkeratoplasty keratometry was used in the calculation of intraocular lens power. The follow-up period ranged from nine to 36 months (18 +/- 9.1 months, mean +/- SD). Six grafts remained clear at the final follow-up. The visual acuity ranged from 20/40 to 20/200 with final astigmatism ranging from 0.5 diopter to 2.0 diopters. One patient developed a retinal detachment 12 months after surgery, which was successfully reattached. One patient, who had preoperative corneal vascularization, had graft rejection, which was treated medically. Our limited series suggests that the triple ocular procedure is a good choice for the treatment of corneolenticular trauma in children. The proper postoperative treatment includes vigorous antiamblyopia therapy and Nd:YAG laser treatment of after-cataracts.
Dosimetry for ultraviolet radiation exposure of the eye
NASA Astrophysics Data System (ADS)
Sliney, David H.
1994-07-01
The eye is exposed daily to UVR from skylight and ground reflections when outdoors in sunlight. Additional exposure occurs daily from artificial sources such as fluorescent lamps. Some workers, notably welders, are exposed to industrial sources of UVR. The geometry of exposure critically influences the actual UVR dose to the cornea and lens. When exposed to bright light, squinting reduces UVR exposure. the optical properties of the eye and behavioral responses to bright light both contribute to limiting actual UVR exposure. The actual daily dos of UVR is considerably less than what many previous investigators have assumed. The geometrical, as well as temporal and spectral, aspects of ocular dosimetry will be reviewed in order to allow participants a better insight into the practical impact of many laboratory studies of UVR effects upon ocular tissues.
Ocular and orbital porcupine quills in the dog: a review and case series.
Grahn, B H; Szentimrey, D; Pharr, J W; Farrow, C S; Fowler, D
1995-01-01
A retrospective evaluation of 5 cases of orbital or intraocular porcupine quills in the dog and a literature review from MEDLINE (1983-1995) is presented. This paper reviews the diagnosis, therapy, and visual prognosis of ocular and orbital quills in the dog. Distinguishing penetration and perforation of the eye and intraocular structures is paramount in establishing a visual prognosis and appropriate therapy. Perforation of the cornea or sclera, lens, or the uvea and retina necessitates prompt specialized surgical therapy to save vision. The diagnosis of orbital quills can be readily confirmed with ultrasonography. The characteristic sonographic appearance of a double-banded, linear, hyperechoic object allows accurate localization of the quill, which aids surgical removal. Images Figure 1. Figure 2. Figure 3. Figure 4. Figure 5. Figure 6. PMID:7585434
Kim, Jin Young; Song, Ji Yun; Karnam, Santi; Park, Jun Young; Lee, Jamie J H; Kim, Seonhee; Cho, Seo-Hee
2015-01-01
Crumbs polarity complex proteins are essential for cellular and tissue polarity, and for adhesion of epithelial cells. In epithelial tissues deletion of any of three core proteins disrupts localization of the other proteins, indicating structural and functional interdependence among core components. Despite previous studies of function and co-localization that illustrated the properties that these proteins share, it is not known whether an individual component of the complex plays a distinct role in a unique cellular and developmental context. In order to investigate this question, we primarily used confocal imaging to determine the expression and subcellular localization of the core Crumbs polarity complex proteins during ocular development. Here we show that in developing ocular tissues core Crumbs polarity complex proteins, Crb, Pals1 and Patj, generally appear in an overlapping pattern with some exceptions. All three core complex proteins localize to the apical junction of the retinal and lens epithelia. Pals1 is also localized in the Golgi of the retinal cells and Patj localizes to the nuclei of the apically located subset of progenitor cells. These findings suggest that core Crumbs polarity complex proteins exert common and independent functions depending on cellular context. Copyright © 2015 Elsevier B.V. All rights reserved.
Orbital extraskeletal osteosarcoma following enucleation in a cat: a case report.
Groskopf, Brooke S; Dubielzig, Richard R; Beaumont, Stephanie L
2010-05-01
We present a unique case of a feline orbital extraskeletal osteosarcoma that developed 5 years post-enucleation. In 2002, an ophthalmologist enucleated the left eye of a 2-year-old neutered male DSH and submitted it to the Comparative Ocular Pathology Laboratory of Wisconsin (COPLOW). COPLOW diagnosed the left eye with feline diffuse iris melanoma. In June 2007, the cat presented to another veterinarian for moderate swelling of the enucleation site. Palpation suggested a firm mass along the lateral orbital rim and an exploratory orbitotomy revealed a cyst with a mass adhered to it and the ventrolateral orbital rim. The cyst and mass were excised by the veterinarian and submitted to COPLOW. COPLOW diagnosed the tissue as an orbital conjunctival inclusion cyst and an acquired orbital osteosarcoma. Following the enucleation, retained conjunctival epithelium became embedded in the connective tissue of the orbit and caused a cyst to develop. The cyst wall consisted of a myofibroblastic collagen-rich matrix and acted as a nidus of chronic irritation and tumor growth. This orbital osteosarcoma resembles feline vaccine-associated sarcomas (VAS), feline post-traumatic ocular sarcomas, and microchip-associated sarcomas in terms of it histopathology and its hypothesized pathogenesis related to exposure to antigenic material such as implanted epithelium, lens protein, vaccine components, and microchips as foreign bodies.
Sun, I-Ting; Lee, Tsung-Han; Chen, Chih-Hsin
2017-01-01
We report a case of rapid cataract progression after Nd:YAG vitreolysis for vitreous floaters. A 55-year-old man presented with acute onset of blurred vision following Nd:YAG vitreolysis for symptomatic floaters in the left eye. His initial best corrected visual acuity (BCVA) was 20/1,000 in the left eye. Ocular examinations showed frost-like opacities of the lens and a suspected break of the posterior capsule in the left eye. There were no detectable retinal lesions. Cataract surgery was then arranged. Posterior capsular rupture and vitreous loss occurred during surgery, which required a subsequent pars plana vitrectomy. After the surgery, BCVA in the left eye gradually improved to 20/20 and was maintained during a 1-year follow-up period. Crystalline lens injuries and rapid cataract progression may occur following Nd:YAG vitreolysis. While dealing with this type of complicated cataract, clinicians should be aware of the possibility of posterior lens capsule rupture during surgery and the need for combined vitrectomy.
Spontaneous Anterior Lens Capsule Rupture Of a Patient with Alport Syndrome - A Case Report.
Trifonova, Kalina; Jordanoff, George; Stoyanov, Valentin; Slaveykov, Kiril
2017-12-15
Alport syndrome is a progressive genetic disease which is characterised by glomerulonephritis, sensorineural deafness and ocular abnormalities. We aimed to present a clinical case of a patient with Alport syndrome with spontaneous anterior lens capsule rupture. A 16-year-old male with histologically proven Alport syndrome was hospitalised in the Department of Ophthalmology, University Hospital "Prof. Stoyan Kirkovich", Stara Zagora with low vision, pain, redness, high IOP and rupture of the anterior lenticular capsule of the right eye. Phacoaspiration was successfully performed (Millenium, Bausch& Lomb, Rochester, New York, USA) with the bimanual irrigation-aspiration system (Geuder AG, Heidelberg, Germany) with excellent visual results. As the syndrome is quite rare and can lead to diagnostic difficulties for the ophthalmologist complications such as spontaneous or traumatic rupture of the capsule are not uncommon. In such cases, phacoaspiration is an efficient method for clear lens extraction after ruptures of the anterior lenticular capsule of young patients with Alport syndrome.
Relationship between relative lens position and appositional closure in eyes with narrow angles.
Otori, Yasumasa; Tomita, Yuki; Hamamoto, Ayumi; Fukui, Kanae; Usui, Shinichi; Tatebayashi, Misako
2011-03-01
To investigate the relationship between relative lens position (RLP) and appositional closure in eyes with narrow angles. Ultrasound biomicroscopy (UBM) was used to measure anterior chamber depth (ACD) and lens thickness (LT), and the IOLMaster to measure axial length (AL). The number of quadrants with appositional closure was assessed by UBM under dark conditions. The RLP was calculated thus: RLP = 10 × (ACD + 0.5 LT) /AL. This study comprised 30 consecutive patients (30 eyes) with narrow-angle eyes defined as Shaffer grade 2 or lower and without peripheral anterior synechiae (24 women, 6 men; mean age ± SD, 67.3 ± 10.4 years; range, 42-87 years). Under dark conditions, 66.7% of the eyes with narrow angles showed appositional closure in at least one quadrant. Of the various ocular biometric parameters, only the RLP significantly decreased with appositional closure in at least one quadrant (P = 0.005). A decrease in the RLP can be predictive of appositional closure for narrow-angle eyes under dark conditions.
Ophthalmic Manifestations of Xeroderma Pigmentosum: A Perspective from the United Kingdom.
Lim, Rongxuan; Sethi, Mieran; Morley, Ana M S
2017-11-01
To document the ocular manifestations of xeroderma pigmentosum (XP), presenting via the United Kingdom (UK) XP service, and to analyze the correlations between XP genotype and ophthalmic phenotype. Prospective observational case series. Eighty-nine patients seen by the UK Nationally Commissioned XP Service, from April 2010 to December 2014, with a genetically confirmed diagnosis of XP. Patients underwent a full ophthalmic examination at each visit. Clinical features from both eyes were recorded on a standard proforma. The most recent assessments were analyzed. A 2-tailed Fisher exact test was used to assess for differences in ocular features between patients in XP subgroups with impaired transcription coupled nucleotide excision repair (TC-NER) (category 1: XP-A, B, D, F, and G) and preserved TC-NER (category 2: XP-C, E, and V). Lid and periocular abnormalities, ocular surface pathologies, neuro-ophthalmologic abnormalities, lens and retinal abnormalities, and visual acuity (VA). Ninety-three percent of XP patients in our cohort had ocular involvement, with 65% describing photophobia. The most common abnormalities were in the periocular skin and ocular surface, including interpalpebral conjunctival melanosis (44%) and conjunctival injection (43%). Eleven percent of patients had required treatment for periocular cancers and 2% for ocular surface cancers. The most common neuro-ophthalmologic finding was minimal pupillary reaction to light (25%). Patients in category 2 had significantly more ocular surface abnormalities than patients in category 1, including a greater proportion of conjunctival injection (P = 0.003), conjunctival corkscrew vessels (P < 0.001), corneal scarring (P = 0.01) and pingueculae under the age of 50 (P = 0.02). Meanwhile, patients in category 1 had a higher proportion of poorly reactive pupils (P < 0.001) and abnormal ocular movements (P = 0.03) compared with those in category 2. Five patients (6%) presented to ophthalmologists with ocular surface signs related to XP, before any formal diagnosis of XP was made. A large proportion of XP patients have ocular involvement. Regular examination by an ophthalmologist is essential, especially in screening for eyelid and ocular surface tumors. The ocular phenotype-genotype segregation within XP patients suggests that XP is a heterogeneous and complex disease. With further study, we hope to offer these patients more individualized patient care. Copyright © 2017 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Shigeyasu, Chika; Yamada, Masakazu; Akune, Yoko; Fukui, Masaki
2017-12-13
To evaluate the changes in ocular surface mucins with 2%rebamipide ophthalmic suspension treatment in soft contact lens (SCL) wearers. Rebamipide suspension is a mucin secretagogue approved for the treatment of dry eye syndrome in Japan. In this study, the fluorescence intensity of wheat germ agglutinin conjugate of fluorescein (F-WGA) was used as a marker of membrane-associated mucins, and sialic acid concentration in tear fluids as a marker of secreted mucins. Thirty-two eyes of 16 SCL wearers with discomfort were treated with rebamipide suspension at a dose of one drop in each eye four times daily for two weeks. The parameters of clinical efficacy were tear break-up time, fluorescein staining scores for the cornea and conjunctiva, and Schirmer test values. Fluorescence intensities in the central cornea were measured by fluorophotometry after the application of 5% F-WGA solution. Tears collected by Schirmer test strips were analyzed by high-performance liquid chromatography, and the concentrations of sialic acid, total protein, and the four major tear proteins, namely secretory IgA, lactoferrin, lipocalin-1, and lysozyme were measured. Significant increases in F-WGA fluorescence intensities (p < 0.005) were seen in the corneal surfaces. Sialic acid concentrations increased over time; however, the differences were not statistically significant. Except for a slight increase in kerato-conjunctival staining scores (p < 0.05) and secretory IgA (p < 0.05), no other significant differences were seen among clinical parameters or tear proteins. Topical application of rebamipide suspension significantly increased F-WGA intensity, a marker of membrane-associated mucins in SCL wearers. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
Kohnen, Thomas; Herzog, Michael; Hemkeppler, Eva; Schönbrunn, Sabrina; De Lorenzo, Nina; Petermann, Kerstin; Böhm, Myriam
2017-12-01
To evaluate visual performance after implantation of a quadrifocal intraocular lens (IOL). Setting: Department of Ophthalmology, Goethe University, Frankfurt, Germany. Twenty-seven patients (54 eyes) received bilateral implantation of the PanOptix IOL (AcrySof IQ PanOptixTM; Alcon Research, Fort Worth, Texas, USA) pre-enrollment. Exclusion criteria were previous ocular surgeries, corneal astigmatism of >1.5 diopter (D), ocular pathologies, or corneal abnormalities. Intervention or Observational Procedure(s): Postoperative examination at 3 months including manifest refraction; uncorrected visual acuity (UCVA) and distance-corrected visual acuity (DCVA) in 4 m, 80 cm, 60 cm, and 40 cm slit-lamp examination; defocus testing; contrast sensitivity (CS) under photopic and mesopic conditions; and a questionnaire on subjective quality of vision, optical phenomena, and spectacle independence was performed. At 3 months postoperatively, UCVA and DCVA in 4 m, 80 cm, 60 cm, and 40 cm (logMAR), defocus curves, CS, and quality-of-vision questionnaire results. Mean spherical equivalent was -0.04 ± 0.321 D 3 months postoperatively. Binocular UCVA at distance, intermediate (80 cm, 60 cm), and near was 0.00 ± 0.094 logMAR, 0.09 ± 0.107 logMAR, 0.00 ± 0.111 logMAR, and 0.01 ± 0.087 logMAR, respectively. Binocular defocus curve showed peaks with best visual acuity (VA) at 0.00 D (-0.07 logMAR) and -2.00 D (-0.02 logMAR). Visual performance of the PanOptix IOL showed good VA at all distances; particularly good intermediate VA (logMAR > 0.1), with best VA at 60 cm; and high patient satisfaction and spectacle independence 3 months postoperatively. Copyright © 2017 Elsevier Inc. All rights reserved.
Terveen, Daniel C; Fram, Nicole R; Ayres, Brandon; Berdahl, John P
2016-02-01
To determine the visual outcomes and complications of a new small-incision technique for 4-point fixation of a hydrophilic acrylic posterior chamber intraocular lens (IOL) in the absence of capsule support. Three North American tertiary referral centers and a private practice. Retrospective case series. Secondary IOL placement was performed from 2011 to 2014. Indications for surgery, clinical results, and complications were analyzed. Primary outcomes included postoperative corrected distance visual acuity (CDVA) and surgical complications. Charts of 35 patients (37 eyes) were reviewed. The mean age at surgery was 56 years, and the mean follow-up was 6 months (range 3 to 24 months). Clinical indications included a dislocated IOL (30%), ocular trauma (19%), crystalline lens subluxation (19%), uveitis-glaucoma-hyphema syndrome (5%), post-complicated cataract (8%), congenital cataract (8%), and decompensated cornea (3%). The mean CDVA improved from 20/80 preoperatively to 20/40 postoperatively (P < .01). Thirty-six eyes (97%) had an improved or unchanged CDVA, and 1 eye (3%) had a reduced CDVA because of worsening glaucoma. Postoperative complications included ocular hypertension (24%), iritis (5%), wound leakage (3%), transient corneal edema (3%), glaucoma requiring a tube shunt (3%), and IOL dislocation (3%). Small-incision 4-point scleral fixation of the Akreos AO60 hydrophilic acrylic IOL in the absence of capsule support appears to be a safe and effective technique for secondary IOL placement. Drs. Berdahl and Ayres are consultants to Bausch & Lomb, Inc. Drs. Ayres and Fram have received speaker fees from Bausch & Lomb. Dr. Terveen does not have a financial or proprietary interest in any material or methods mentioned. Copyright © 2016 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Ocular response to environmental variations in contact lens wearers.
López-de la Rosa, Alberto; Martín-Montañez, Vicente; López-Miguel, Alberto; Fernández, Itziar; Calonge, Margarita; González-Méijome, José M; González-García, María J
2017-01-01
To assess the influence of different indoor environments simulated in an environmental chamber on soft contact lens (CL) wearers. Fifty-four CL wearers were grouped based on their symptoms while wearing their CLs. Subjects were fitted with two different CL types, conventional hydrogel (Omafilcon A) and silicone hydrogel (comfilcon A), and exposed to two controlled indoor environmental conditions, standard [50% relative humidity (RH), 23°C, 930 mb of atmospheric pressure] and adverse (in-flight air cabin environment: 5% RH, localised air flow, 23°C, 750 mb atmospheric pressure), for 90 min in an environmental chamber, making a total of four visits. Symptoms, tear osmolarity, pre-lens tear breakup time (PLBUT), phenol red thread test, visual acuity, bulbar and limbal hyperaemia, corneal and limbal staining, and CL dehydration were assessed using repeated measures analysis of variance. A linear mixed model was used to analyse the effect of environment, CL type, discomfort-based grouping, and time on blink rate. Environment was found to significantly (p ≤ 0.018) affect limbal and bulbar hyperaemia, PLBUT, tear osmolarity, and CL dehydration. Likewise, CL type significantly (p ≤ 0.04) affected nasal and total corneal staining, limbal conjunctival staining, CL dehydration, comfort, and blurred vision. The environment, CL type, and time had significant effects (p ≤ 0.0001) on the blink rate. Ocular surface integrity and blink rate in CL wearers depend on the environment CL users are exposed to, as well as on the soft CL type that they are wearing. Tight control of environmental conditions can contribute to a better understanding of CL-related discomfort. © 2016 The Authors Ophthalmic & Physiological Optics © 2016 The College of Optometrists.
Dynamic Contour Tonometry (DCT) over a thin daily disposable hydrogel contact lens.
Nosch, Daniela Sonja; Duddek, Armin P; Herrmann, Didier; Stuhrmann, Oliver M
2010-10-01
Dynamic Contour Tonometry (DCT) has been shown to measure the intraocular pressure (IOP) independent of corneal physical properties such as thickness, curvature and rigidity. The aim of this study was to find out if DCT remains accurate when it is applied on regularly shaped corneas while a thin, daily hydrogel contact lens (CL) is worn. This was a prospective, randomised study and included 46 patients (46 right eyes): 26 females and 20 males. The age varied from 22 to 66 years (mean: 43.0+/-12.70 years). IOP and ocular pulse amplitude (OPA) measurements were taken with and without a daily disposable hydrogel CL (-0.50 D), Filcon IV) in situ (using the DCT), with a randomised order of measurements. The average value for the IOP measurements without CL was 16.51+/-3.20 mmHg, and with CL in situ it was 16.10+/-3.10 mmHg. The mean difference was 0.41 mmHg and not found to be statistically significant (p=0.074). The average value for the OPA measurement without CL was 2.20+/-0.79 mmHg. With CL in situ it was 2.08+/-0.81 mmHg. This gave a mean difference of 0.11 mmHg and was statistically significant (p=0.025). The Bland-Altman plot showed a maximum difference in IOP of +2.44 and -2.00 mmHg (CI 0.95). Regarding OPA, the maximum difference was +0.81 and -0.60 mmHg (CI 0.95). The presence of a thin hydrogel CL did not affect the accuracy of IOP measurements using the DCT. The ocular pulse amplitude was measured on average 5.45% lower with a CL in situ. Copyright (c) 2010 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
Lens-based wavefront sensorless adaptive optics swept source OCT
NASA Astrophysics Data System (ADS)
Jian, Yifan; Lee, Sujin; Ju, Myeong Jin; Heisler, Morgan; Ding, Weiguang; Zawadzki, Robert J.; Bonora, Stefano; Sarunic, Marinko V.
2016-06-01
Optical coherence tomography (OCT) has revolutionized modern ophthalmology, providing depth resolved images of the retinal layers in a system that is suited to a clinical environment. Although the axial resolution of OCT system, which is a function of the light source bandwidth, is sufficient to resolve retinal features at a micrometer scale, the lateral resolution is dependent on the delivery optics and is limited by ocular aberrations. Through the combination of wavefront sensorless adaptive optics and the use of dual deformable transmissive optical elements, we present a compact lens-based OCT system at an imaging wavelength of 1060 nm for high resolution retinal imaging. We utilized a commercially available variable focal length lens to correct for a wide range of defocus commonly found in patient’s eyes, and a novel multi-actuator adaptive lens for aberration correction to achieve near diffraction limited imaging performance at the retina. With a parallel processing computational platform, high resolution cross-sectional and en face retinal image acquisition and display was performed in real time. In order to demonstrate the system functionality and clinical utility, we present images of the photoreceptor cone mosaic and other retinal layers acquired in vivo from research subjects.
Ciolino, Joseph B.; Hoare, Todd R.; Iwata, Naomi G.; Behlau, Irmgard; Dohlman, Claes H.; Langer, Robert; Kohane, Daniel S.
2014-01-01
Purpose To formulate and characterize a drug-eluting contact lens designed to provide extended, controlled release of a drug. Methods Prototype contact lenses were created by coating PLGA (poly[lactic-co-glycolic acid]) films containing test compounds with pHEMA (poly[hydroxyethyl methacrylate]) by ultraviolet light polymerization. The films, containing encapsulated fluorescein or ciprofloxacin, were characterized by scanning electron microscopy. Release studies were conducted in phosphate-buffered saline at 37°C with continuous shaking. Ciprofloxacin eluted from the contact lens was studied in an antimicrobial assay to verify antimicrobial effectiveness. Results After a brief and minimal initial burst, the prototype contact lenses demonstrated controlled release of the molecules studied, with zero-order release kinetics under infinite sink conditions for over 4 weeks. The rate of drug release was controlled by changing either the ratio of drug to PLGA or the molecular mass of the PLGA used. Both the PLGA and the pHEMA affected release kinetics. Ciprofloxacin released from the contact lenses inhibited ciprofloxacin-sensitive Staphylococcus aureus at all time-points tested. Conclusions A prototype contact lens for sustained drug release consisting of a thin drug-PLGA film coated with pHEMA could be used as a platform for ocular drug delivery with widespread therapeutic applications. PMID:19136709
Rabbits' eye globe sonographic biometry.
Toni, Maria Carolina; Meirelles, Adriana Érica Wilkes Burton; Gava, Fábio Nelson; Camacho, Aparecido Antônio; Laus, José Luiz; Canola, Júlio Carlos
2010-11-01
To measure intraocular structures in New Zealand White breed rabbits (Oryctolagus cuniculus Linnaeus, 1758) using A-mode and B-mode ultrasound with a 20 MHz transducer. In this study, the eyes of 15 rabbits were evaluated for determination of intraocular measurements using an ophthalmic ultrasound unit able to operate in both A and B-modes. The distances from the cornea to the anterior capsule of the lens (D1), from the anterior capsule of the lens to the posterior capsule of the lens (D2), from the posterior capsule of the lens to the retina (D3) and the complete length of the eye, which corresponds to the distance from the cornea to the retina (D4) were taken. The mean values obtained were 2.70 mm (± 0.22 mm) for D1, 7.32 mm (± 0.40 mm) for D2, 7.10 mm (± 0.45 mm) for D3 and 17.12 mm (± 0.41 mm) for D4. Statistical analyses using the Student's t-test showed that there were no differences between the eyes. The study was feasible without the need of pharmacological restraint and yielded normal mean values for ocular sonographic biometry in rabbits. © 2010 American College of Veterinary Ophthalmologists.
Effects of lactoferricin B against keratitis-associated fungal biofilms.
Sengupta, Jayangshu; Saha, Suman; Khetan, Archana; Sarkar, Sujoy K; Mandal, Santi M
2012-10-01
Biofilms are considered as the most important developmental characteristics in ocular infections. Biofilm eradication is a major challenge today to overcome the incidence of drug resistance. This report demonstrates the in vitro ability of biofilm formation on contact lens by three common keratitis-associated fungal pathogens, namely, Aspergillus fumigatus, Fusarium solani, and Candida albicans. Antifungal sensitivity testing performed for both planktonic cells and biofilm revealed the sessile phenotype to be resistant at MIC levels for the planktonic cells and also at higher concentrations. A prototype lens care solution was also found to be partially effective in eradication of the mature biofilm from contact lenses. Lactoferricin B (Lacf, 64 μg/ml), an antimicrobial peptide, exhibited almost no effect on the sessile phenotype. However, the combinatory effect of Lacf with antifungals against planktonic cells and biofilms of three fungal strains that were isolated from keratitis patients exhibited a reduction of antifungal dose more than eightfold. Furthermore, the effect of Lacf in lens care solution against biofilms in which those strains formed was eradicated successfully. These results suggest that lactoferricin B could be a promising candidate for clinical use in improving biofilm susceptibility to antifungals and also as an antibiofilm-antifungal additive in lens care solution.
NASA Astrophysics Data System (ADS)
De Freitas, Carolina; Hernandez, Victor M.; Ruggeri, Marco; Durkee, Heather A.; Williams, Siobhan; Gregori, Giovanni; Ho, Arthur; Manns, Fabrice; Parel, Jean-Marie
2016-03-01
The purpose of this project is to design and evaluate a system that will enable objective assessment of the optical accommodative response in real-time while acquiring axial biometric information. The system combines three sub-systems which were integrated and mounted on a joystick x-y-z adjustable modified slit-lamp base to facilitate alignment and data acquisition: (1) a Shack-Hartmann wavefront sensor for dynamic refraction measurement, provided software calculates sphere, cylinder and axis values, (2) an extended-depth Optical Coherence Tomography (OCT) system using an optical switch records high-resolution cross-sectional images across the length of the eye, from which, dynamic axial biometry (corneal thickness, anterior chamber depth, crystalline lens thickness and vitreous depth) can be extracted, and (3) a modified dual-channel accommodation stimulus unit based on the Badal optometer for providing a step change in accommodative stimulus. The prototypal system is capable of taking simultaneous measurements of both the optical and the mechanical response of lens accommodation. These measurements can provide insight into correlating changes in lens shape with changes in lens power and ocular refraction and ultimately provide a more comprehensive understanding of accommodation, presbyopia and an objective assessment of presbyopia correction techniques.
Corneal confocal microscopy and dry eye findings in contact lens discomfort patients.
Dogan, Aysun Sanal; Gurdal, Canan; Arslan, Nese
2018-02-01
To evaluate the corneal confocal microscopy and dry eye findings in patients with contact lens discomfort. The study included 3 groups of participants: Contact lens wearers using silicone hydrogel soft contact lenses who are symptomatic (CLD, n=15) or asymptomatic (ACL, n=11) and non-wearers as controls (n=14). Duration of contact lens wear, Ocular Surface Disease Index (OSDI) questionnaire responses, fluorescein tear break-uptime (FBUT), and corneal confocal microscopy findings were recorded. Mean age was 25.7±8.2 years and male/female ratio was 7/33. Demographic findings were similar regarding the groups. CLD patients had a longer lens use history than ACL (median 5 vs 2 years, p<0.001). OSDI scores were higher in CLD group than ACL or controls (p<0.001, p=0.002). FBUT was significantly lowest in CLD group, compared to controls and ACL (p<0.001, p=0.039). FBUT was also lower in ACL patients compared to controls (p=0.036). There was no difference between basal epithelium cell counts between all 3 groups. Anterior stromal activated keratocyte numbers were similar between contact lens using groups but was lower in controls (p=0.005). However, dendritiform cells in the sub-basal nerve layer were higher in CLD group compared to controls but similar to ACL (p<0.001, p=0.058). Graded sub-basal nerve tortuosity was more prominent in CLD group than the ACL (p=0.014). Patients with CLD had been wearing contact lenses for longer than those without symptoms. OSDI and FBUT scores were worse in CLD patients. In contact lens discomfort patients, there were increased dendritiform cells, indicating intensified inflammatory status of the cornea. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
Dadoukis, Panagiotis; Klagas, Ioannis; Komnenou, Anastasia; Karakiulakis, George; Karoutis, Athanasios; Karampatakis, Vassilios; Papakonstantinou, Eleni
2013-08-01
Prolonged exposure to infrared (IR) radiation is associated with different types of damage to cornea and lens. The aim of our study was to investigate the effect of acute and chronic exposure to IR radiation on the activity of matrix metalloproteinase-2 (MMP-2) and MMP-9 and on the expression of glycosaminoglycans (GAG) in the rabbit cornea and crystalline lens. New Zealand rabbits were subjected to IR radiation for 4 months (chronic exposure to IR) or to normal light (control group). In experiments regarding acute exposure, animals were subjected to IR radiation or normal light for 12 h, in the presence of 0.1% diclofenac sodium (eye drops instilled in the right eye of animals) or saline (instilled in the left eye of animals). The cornea and lens were dissected away and homogenized. The activity of MMP-2 and MMP-9 was assayed by gelatine zymography. Total GAG were isolated from tissue specimens after lipid extraction and extensive digestion with pronase and DNase and characterized by treatment with GAG-degrading enzymes, followed by electrophoresis on cellulose acetate membranes. Acute or chronic exposure to IR radiation induced the activity of MMP-2 in cornea and lens, whereas only acute IR radiation increased the content of heparan sulphate in crystalline lens. Local administration of diclofenac sodium did not prevent the above effects of acute IR radiation. The detrimental effects of excessive or prolonged exposure of the eyes to IR radiation are associated with induced activity of MMP-2 in cornea and lens and alterations in the content of heparan sulphate in lens. Thus, MMP and GAG may offer alternative targets for pharmacological intervention to confront ocular damages associated with IR radiation.
Skotnitsky, Cheryl C; Naduvilath, Thomas J; Sweeney, Deborah F; Sankaridurg, Padmaja R
2006-01-01
The purpose of this study was to confirm that two distinct clinical presentations of contact lens-induced papillary conjunctivitis (CLPC), local and general, occur in hydrogel lens wear. Retrospective analyses of 124 CLPC events were identified. The classification of CLPC was based on location and extent of papillae. CLPC was classified as local if papillae were present in one to two areas of the tarsal conjunctiva and general if papillae occurred in three or more areas. The CLPC events were compared with an asymptomatic control group in prospective clinical trials conducted from 1993 until 2003 at two clinical sites, Australia and India. Two hundred sixteen subjects from Australia and 914 subjects from India wore either high Dk silicone hydrogel or low Dk hydrogel lenses on a 6-night (6N) or 30-night extended-wear (EW) schedule. The physiological responses of the ocular surface, including tarsal conjunctiva redness and roughness, number of papillae present, lens fit and performance, and subjective patient symptoms, were measured during each visit at each site. These variables listed were compared between local CLPC groups and asymptomatic controls and general CLPC groups and asymptomatic controls. Two types of CLPC in hydrogel lens wearers have been confirmed. Of the 124 CLPC events, there were 61 local and 63 general events. Local and general CLPC cases reported significantly greater frequency of symptoms compared with the asymptomatic controls, in particular itching, lens awareness, secretion, and blurred vision (p < 0.1). The classification of CLPC into two types, local and general, in hydrogel lens wear was confirmed based on presentations at both sites. This distribution of papillae between local and general CLPC may indicate separate etiologies involved in the pathogenesis of the condition.
High Refractive Index Polysiloxane as Injectable, In Situ Curable Accommodating Intraocular Lens
Hao, Xiaojuan; Jeffery, Justine L.; Le, Tam P.T.; McFarland, Gail; Johnson, Graham; Mulder, Roger J.; Garrett, Qian; Manns, Fabrice; Nankivil, Derek; Arrieta, Esdras; Ho, Arthur; Parel, Jean-Marie; Hughes, Timothy C.
2012-01-01
Functionalised siloxane macromonomers, with properties designed for application as an injectable, in situ curable accommodating intraocular lens (A-IOL), were prepared via reequilibration of a phenyl group-containing polysiloxane of very high molecular weight with octamethylcyclotetrasiloxane (D4) and 2,4,6,8-tetra(n-propyl-3-methacrylate)-2,4,6,8-tetramethylcyclotetrasiloxane (D4AM) in toluene using trifluoromethanesulfonic acid as a catalyst. Hexaethyldisiloxane was used as an end group to control the molecular weight of the polymer. The generated polymers had a consistency suitable for injection into the empty lens capsule. The polymers contained a low ratio of polymerisable groups so that, in the presence of a photo-initiator, they could be cured on demand in situ within 5 minutes under irradiation of blue light to form an intraocular lens within the lens capsule. All resulting polysiloxane soft gels had a low elastic modulus and thus should be able to restore accommodation. The pre-cure viscosity and post-cure modulus of the generated polysiloxanes were controlled by the end group and D4AM concentrations respectively in the re-equilibration reactions. The refractive index could be precisely controlled by adjusting the aromatic ratio in the polymer to suit such application as an artificial lens. Lens stretching experiments with both human and non-human primate cadaver lenses of different ages refilled with polysiloxane polymers provided a significant increase in amplitude of accommodation (up to 4 D more than that of the respective natural lens). Both in vitro cytotoxicity study using L929 cell lines and in vivo biocompatibility study in rabbit models demonstrated the non-cytotoxicity and ocular biocompatibility of the polymer. PMID:22594975
Veli, Muhammed; Ozcan, Aydogan
2018-03-27
We present a cost-effective and portable platform based on contact lenses for noninvasively detecting Staphylococcus aureus, which is part of the human ocular microbiome and resides on the cornea and conjunctiva. Using S. aureus-specific antibodies and a surface chemistry protocol that is compatible with human tears, contact lenses are designed to specifically capture S. aureus. After the bacteria capture on the lens and right before its imaging, the captured bacteria are tagged with surface-functionalized polystyrene microparticles. These microbeads provide sufficient signal-to-noise ratio for the quantification of the captured bacteria on the contact lens, without any fluorescent labels, by 3D imaging of the curved surface of each lens using only one hologram taken with a lens-free on-chip microscope. After the 3D surface of the contact lens is computationally reconstructed using rotational field transformations and holographic digital focusing, a machine learning algorithm is employed to automatically count the number of beads on the lens surface, revealing the count of the captured bacteria. To demonstrate its proof-of-concept, we created a field-portable and cost-effective holographic microscope, which weighs 77 g, controlled by a laptop. Using daily contact lenses that are spiked with bacteria, we demonstrated that this computational sensing platform provides a detection limit of ∼16 bacteria/μL. This contact-lens-based wearable sensor can be broadly applicable to detect various bacteria, viruses, and analytes in tears using a cost-effective and portable computational imager that might be used even at home by consumers.
Dietze, Holger H; Cox, Michael J
2003-02-01
Soft contact lenses produce a significant level of spherical aberration affecting their power on-eye. A simple model assuming that a thin soft contact lens aligns to the cornea predicts that these effects are similar on-eye and off-eye. The wavefront aberration for 17 eyes and 33 soft contact lenses on-eye was measured with a Shack-Hartmann wavefront sensor. The Zernike coefficients describing the on-eye spherical aberration of the soft contact lens were compared with off-eye ray-tracing results. Paraxial and effective lens power changes were determined. The model predicts the on-eye spherical aberration of soft contact lenses closely. The resulting power change for a +/- 7.00 D spherical soft contact lens is +/- 0.5 D for a 6-mm pupil diameter and +/- 0.1 D for a 3-mm pupil diameter. Power change is negligible for soft contact lenses corrected for off-eye spherical aberration. For thin soft contact lenses, the level of spherical aberration and the consequent power change is similar on-eye and off-eye. Soft contact lenses corrected for spherical aberration in air will be expected to be aberration-free on-eye and produce only negligibly small power changes. For soft contact lenses without aberration correction, for higher levels of ametropia and large pupils, the soft contact lens power should be determined with trial lenses with their power and p value similar to the prescribed lens. The benefit of soft contact lenses corrected for spherical aberration depends on the level of ocular spherical aberration.
Contact lens deposits, adverse responses, and clinical ocular surface parameters.
Zhao, Zhenjun; Naduvilath, Thomas; Flanagan, Judith L; Carnt, Nicole A; Wei, Xiaojia; Diec, Jennie; Evans, Vicki; Willcox, Mark D P
2010-09-01
To correlate clinical responses during contact lens wear with the amount of protein or cholesterol extracted from lenses after wear. Clinical parameters, including adverse response rates and corneal staining, and symptomatology rating during lens wear were collected from a series of clinical tests comprising four different silicone hydrogel lenses with four different multipurpose solutions. To test for correlates, the amount of total protein or cholesterol extracted from lenses after daily wear were compared statistically to clinical parameters. The amount of protein (p = 0.008) or cholesterol (p = 0.01) extracted from lenses was higher for those subjects who showed solution-induced corneal staining. Amount of protein extracted was correlated (p < 0.01) with conjunctival staining (R = -0.23), lens front surface wetting (r = 0.14), and lens fit tightness (R = -0.20). These clinical parameters accounted for 48% of lens protein deposition. The amount of cholesterol extracted from lenses was much more weakly associated with clinical variables. Amount of protein or cholesterol extracted from lenses was not associated with the production of any corneal infiltrative or mechanical adverse event during wear and was only very weakly correlated with insertion comfort of lenses. These results suggest that there may be no physiologically relevant consequence of cholesterol depositing on silicone hydrogel lenses. The amount of protein that deposits onto silicone hydrogel lenses during wear may have more affect on lens performance on-eye. However, the correlations were generally small and may still not indicate any causative relevant physiological response. Further work is required to determine whether there is any direct causative effect to support these correlative findings.
Controlled Release of Multiple Therapeutics from Silicone Hydrogel Contact Lenses.
White, Charles James; DiPasquale, Stephen Anthony; Byrne, Mark Edward
2016-04-01
The majority of contact lens wearers experience a significant level of ocular discomfort associated with lens wear, often within hours of wear, related to dry lenses, inflammation, protein adhesion to the lens surface, etc. Application of controlled drug release techniques has focused on the incorporation and/or release of a single comfort molecule from a lens including high molecular weight comfort agents or pharmaceutical agents. Previous studies have sought to mitigate the occurrence of only single propagators of discomfort. Clinical studies with eye drop solutions have shown that a mixture of diverse comfort agents selected to address multiple propagators of discomfort provide the greatest and longest lasting sensations of comfort for the patient. In this paper, multiple propagators of discomfort are addressed through the simultaneous release of four molecules from a novel contact lens to ensure high level of lens wear comfort. Silicone hydrogel contact lenses were engineered via molecular imprinting strategies to simultaneously release up to four template molecules including hydropropyl methylcellulose (HPMC), trehalose, ibuprofen, and prednisolone. By adjusting the ratio of functional monomer to comfort molecule, a high level of control was demonstrated over the release rate. HPMC, trehalose, ibuprofen, and prednisolone were released at therapeutically relevant concentrations with varying rates from a single lens. The results indicate use as daily disposable lenses for single day release or extended-wear lenses with multiple day release. Imprinted lenses are expected to lead to higher efficacy for patients compared to topical eye drops by improving compliance and mitigating concentration peaks and valleys associated with multiple drops.