Teaching beyond the Test: A Method for Designing Test-Preparation Classes
ERIC Educational Resources Information Center
Derrick, Deirdre
2013-01-01
Test-preparation classes that focus on skills will benefit students beyond the test by developing skills they can use at university. This article discusses the purposes of various tests and outlines how to design effective test-prep classes. Several practical activities are included, and an appendix provides information on common standardized…
Development of Guidelines for In-Situ Repair of SLS-Class Composite Flight Hardware
NASA Technical Reports Server (NTRS)
Weber, Thomas P., Jr.; Cox, Sarah B.
2018-01-01
The purpose of composite repair development at KSC (John F. Kennedy Space Center) is to provide support to the CTE (Composite Technology for Exploration) project. This is a multi-space center effort with the goal of developing bonded joint technology for SLS (Space Launch System) -scale composite hardware. At KSC, effective and efficient repair processes need to be developed to allow for any potential damage to composite components during transport or launch preparation. The focus of the composite repair development internship during the spring of 2018 was on the documentation of repair processes and requirements for process controls based on techniques developed through hands-on work with composite test panels. Three composite test panels were fabricated for the purpose of repair and surface preparation testing. The first panel included a bonded doubler and was fabricated to be damaged and repaired. The second and third panels were both fabricated to be cut into lap-shear samples to test the strength of bond of different surface preparation techniques. Additionally, jointed composite test panels were impacted at MSFC (Marshall Space Flight Center) and analyzed for damage patterns. The observations after the impact tests guided the repair procedure at KSC to focus on three repair methods. With a finalized repair plan in place, future work will include the strength testing of different surface preparation techniques, demonstration of repair methods, and repair of jointed composite test panels being impacted at MSFC.
Final Report for X-ray Diffraction Sample Preparation Method Development
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ely, T. M.; Meznarich, H. K.; Valero, T.
WRPS-1500790, “X-ray Diffraction Saltcake Sample Preparation Method Development Plan/Procedure,” was originally prepared with the intent of improving the specimen preparation methodology used to generate saltcake specimens suitable for XRD-based solid phase characterization. At the time that this test plan document was originally developed, packed powder in cavity supports with collodion binder was the established XRD specimen preparation method. An alternate specimen preparation method less vulnerable, if not completely invulnerable to preferred orientation effects, was desired as a replacement for the method.
Preparation of calibrated test packages for particle impact noise detection
NASA Technical Reports Server (NTRS)
1977-01-01
A standard calibration method for any particle impact noise detection (PIND) test system used to detect loose particles responsible for failures in hybrid circuits was developed along with a procedure for preparing PIND standard test devices. Hybrid packages were seeded with a single gold ball, hermetically sealed, leak tested, and PIND tested. Conclusions are presented.
A cognitive behavioral course for at-risk senior nursing students preparing to take the NCLEX.
Poorman, Susan G; Mastorovich, Melissa L; Liberto, Terri L; Gerwick, Michele
2010-01-01
For some nursing students, the stress of preparing for and taking the NCLEX can lead to maladaptive behaviors such as poor test performance and inadequate preparation. A different approach to NCLEX preparation for at-risk seniors is described. A 3-credit course that combines cognitive behavioral techniques, metacognitive strategies, test-taking strategies, and simulated NCLEX experience with practice questions is presented. Students also develop an individualized plan of preparation from graduation until they take the NCLEX.
ERIC Educational Resources Information Center
Carter, Marilyn; And Others
Intended for students preparing for the General Educational Development (GED) test, this workbook enables them to complete lessons in writing and spelling skills and to take the simulated writing skills tests. The first section contains worksheets on basic writing skills, such as sentence structure, capitalization, and punctuation and the use of…
Teacher Competency in Classroom Testing, Measurement Preparation, and Classroom Testing Practices.
ERIC Educational Resources Information Center
Newman, Dorothy C.; Stallings, William M.
An assessment instrument and a questionnaire (Appendices A and B) were developed to determine how well teachers understand classroom testing principles and to gain information on the measurement preparation and classroom practices of teachers. Two hundred ninety-four inservice teachers, grades 1 through 12, from three urban school systems in…
The Development and Validation of a Teacher Preparation Program: Follow-Up Survey
ERIC Educational Resources Information Center
Schulte, Laura E.
2008-01-01
Students in my applied advanced statistics course for educational administration doctoral students developed a follow-up survey for teacher preparation programs, using the following scale development processes: adopting a framework; developing items; providing evidence of content validity; conducting a pilot test; and analyzing data. The students…
Teacher Preparation Practices in Kenya and the 21st Century Learning: A Moral Obligation
ERIC Educational Resources Information Center
Kafwa, Nabwire Opata; Gaudience, Obondo; Kisaka, Sella Terrie
2015-01-01
Teacher preparation practices are indices used to measure quality teacher besides other variables. Whereas the current teacher preparation is test scores based inclining to cognitive knowledge, a good teacher preparation practices is a holistic development in nature oriented towards character, skills and knowledge. To embed teacher preparation in…
Alternatives for Developing User Documentation for Applications Software
1991-09-01
style that is designed to match adult reading behaviors, using reader-based writing techniques, developing effective graphics , creating reference aids...involves research, analysis, design , and testing. The writer must have a solid understanding of the technical aspects of the document being prepared, good...ABSTRACT The preparation of software documentation is an iterative process that involves research, analysis, design , and testing. The writer must have
DOE Office of Scientific and Technical Information (OSTI.GOV)
Larson, D.E.
1996-09-01
This report provides a collection of annotated bibliographies for documents prepared under the Hanford High-Level Waste Vitrification (Plant) Program. The bibliographies are for documents from Fiscal Year 1983 through Fiscal Year 1995, and include work conducted at or under the direction of the Pacific Northwest National Laboratory. The bibliographies included focus on the technology developed over the specified time period for vitrifying Hanford pretreated high-level waste. The following subject areas are included: General Documentation; Program Documentation; High-Level Waste Characterization; Glass Formulation and Characterization; Feed Preparation; Radioactive Feed Preparation and Glass Properties Testing; Full-Scale Feed Preparation Testing; Equipment Materials Testing; Meltermore » Performance Assessment and Evaluations; Liquid-Fed Ceramic Melter; Cold Crucible Melter; Stirred Melter; High-Temperature Melter; Melter Off-Gas Treatment; Vitrification Waste Treatment; Process, Product Control and Modeling; Analytical; and Canister Closure, Decontamination, and Handling« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Haas, J.C.; Olivo, C.A.; Wilson, K.B.
1994-04-01
An experimental test plan has been prepared for DOE/METC review and approval to develop a filter media suitable for multi-contaminant control in granular-bed filter (GBF) applications. The plan includes identification, development, and demonstration of methods for enhanced media morphology, chemical reactivity, and mechanical strength. The test plan includes media preparation methods, physical and chemical characterization methods for fresh and reacted media, media evaluation criteria, details of test and analytical equipment, and test matrix of the proposed media testing. A filter media composed of agglomerated limestone and clay was determined to be the best candidate for multi-contaminate control in GBF operation.more » The combined limestone/clay agglomerate has the potential to remove sulfur and alkali species, in addition to particulate, and possibly halogens and trace heavy metals from coal process streams.« less
GED Test Preparation: Practical Reading. Nutrition, Health, Recipes.
ERIC Educational Resources Information Center
Goodman, Deborah
These instructional materials provide reading materials, recipes, and exercises to help students prepare for the practical reading section of the General Educational Development (GED) Tests. The passages can also help students learn and practice some important life skills in the areas of nutrition and food safety. Basic skill improvement is in…
ERIC Educational Resources Information Center
Norris, John; Drackert, Anastasia
2018-01-01
The Test of German as a Foreign Language (TestDaF) plays a critical role as a standardized test of German language proficiency. Developed and administered by the Society for Academic Study Preparation and Test Development (g.a.s.t.), TestDaF was launched in 2001 and has experienced persistent annual growth, with more than 44,000 test takers in…
Future aerospace ground test facility requirements for the Arnold Engineering Development Center
NASA Technical Reports Server (NTRS)
Kirchner, Mark E.; Baron, Judson R.; Bogdonoff, Seymour M.; Carter, Donald I.; Couch, Lana M.; Fanning, Arthur E.; Heiser, William H.; Koff, Bernard L.; Melnik, Robert E.; Mercer, Stephen C.
1992-01-01
Arnold Engineering Development Center (AEDC) was conceived at the close of World War II, when major new developments in flight technology were presaged by new aerodynamic and propulsion concepts. During the past 40 years, AEDC has played a significant part in the development of many aerospace systems. The original plans were extended through the years by some additional facilities, particularly in the area of propulsion testing. AEDC now has undertaken development of a master plan in an attempt to project requirements and to plan for ground test and computational facilities over the coming 20 to 30 years. This report was prepared in response to an AEDC request that the National Research Council (NRC) assemble a committee to prepare guidance for planning and modernizing AEDC facilities for the development and testing of future classes of aerospace systems as envisaged by the U.S. Air Force.
Development of a National Item Bank for Tests of Driving Knowledge.
ERIC Educational Resources Information Center
Pollock, William T.; McDole, Thomas L.
Materials intended for driving knowledge test development use by operational licensing and education agencies were prepared. Candidate test items were developed, using literature and operational practice sources, to reflect current state-of-knowledge with respect to principles of safe, efficient driving, to legal regulations, and to traffic…
Development and stability of semisolid preparations based on a supercritical CO2 Arnica extract.
Bilia, Anna Rita; Bergonzi, Maria Camilla; Mazzi, Giovanni; Vincieri, Franco Francesco
2006-05-03
Conventional herbal drug preparations (HDP) based on Arnica montana L. have a low content of the active principles, sesquiterpene lactones, which show poor stability and low physical compatibility in semisolid formulations. Recently, an innovative supercritical carbon dioxide (CO2) extract with high sesquiterpene content has been marketed. Development of six semisolid preparations (cetomacrogol, polysorbate 60, polawax, anphyphil, natrosol and sepigel) based on this innovative CO2 extract is discussed. Stability of these preparations was investigated according to ICH guidelines. The evaluation of in vitro release of active constituents was performed using the cell method reported in the European Pharmacopoeia. Preliminary data on in vivo permeation of three selected formulations is demonstrated using the "skin stripping" test, according to the FDA, in healthy subjects. Analysis of sesquiterpene lactones within the extract and in vitro and in vivo studies was performed by RP-HPLC-DAD-MS method. The cetomacrogol showed the best release profile in the in vitro test, while in the in vivo test the best preparation resulted polysorbate 60 and polawax.
Evaluation of new binders using newly developed fracture energy test.
DOT National Transportation Integrated Search
2013-07-01
This study evaluated a total of seven asphalt binders with various additives : using the newly developed binder fracture energy test. The researchers prepared and : tested PAV-aged and RTFO-plus-PAV-aged specimens. This study confirmed previous : res...
Preparation on Earth for Drilling on Mars
2013-02-20
The development of the Mars rover Curiosity capabilities for drilling into a rock on Mars required years of development work. Seen here are some of the rocks used in bit development testing and lifespan testing at JPL in 2007.
Oxygen electrodes for rechargeable alkaline fuel cells
NASA Technical Reports Server (NTRS)
Swette, Larry; Giner, Jose
1987-01-01
Electrocatalysts and supports for the positive electrode of moderate temperature single unit rechargeable alkaline fuel cells were investigated and developed. The electrocatalysts are defined as the material with a higher activity for the oxygen electrode reaction than the support. Advanced development will require that the materials be prepared in high surface area forms, and may also entail integration of various candidate materials. Eight candidate support materials and seven electrocatalysts were investigated. Of the 8 support, 3 materials meet the preliminary requirements in terms of electrical conductivity and stability. Emphasis is now on preparing in high surface area form and testing under more severe corrosion stress conditions. Of the 7 electrocatalysts prepared and evaluated, at least 5 materials remain as potential candidates. The major emphasis remains on preparation, physical characterization and electrochemical performance testing.
Commercial Supersonics Technology Project - Status of Airport Noise
NASA Technical Reports Server (NTRS)
Bridges, James
2016-01-01
The Commercial Supersonic Technology Project has been developing databases, computational tools, and system models to prepare for a level 1 milestone, the Low Noise Propulsion Tech Challenge, to be delivered Sept 2016. Steps taken to prepare for the final validation test are given, including system analysis, code validation, and risk reduction testing.
Exploring Operational Test and Evaluation of Unmanned Aircraft Systems: A Qualitative Case Study
NASA Astrophysics Data System (ADS)
Saliceti, Jose A.
The purpose of this qualitative case study was to explore and identify strategies that may potentially remedy operational test and evaluation procedures used to evaluate Unmanned Aircraft Systems (UAS) technology. The sample for analysis consisted of organizations testing and evaluating UASs (e.g., U.S. Air Force, U.S. Navy, U.S. Army, U.S. Marine Corps, U.S. Coast Guard, and Customs Border Protection). A purposeful sampling technique was used to select 15 subject matter experts in the field of operational test and evaluation of UASs. A questionnaire was provided to participants to construct a descriptive and robust research. Analysis of responses revealed themes related to each research question. Findings revealed operational testers utilized requirements documents to extrapolate measures for testing UAS technology and develop critical operational issues. The requirements documents were (a) developed without the contribution of stakeholders and operational testers, (b) developed with vague or unrealistic measures, and (c) developed without a systematic method to derive requirements from mission tasks. Four approaches are recommended to develop testable operational requirements and assist operational testers: (a) use a mission task analysis tool to derive requirements for mission essential tasks for the system, (b) exercise collaboration among stakeholders and testers to ensure testable operational requirements based on mission tasks, (c) ensure testable measures are used in requirements documents, and (d) create a repository list of critical operational issues by mission areas. The preparation of operational test and evaluation processes for UAS technology is not uniform across testers. The processes in place are not standardized, thus test plan preparation and reporting are different among participants. A standard method to prepare and report UAS technology should be used when preparing and reporting on UAS technology. Using a systematic process, such as mission-based test design, resonated among participants as an analytical method to link UAS mission tasks and measures of performance to the capabilities of the system under test when developing operational test plans. Further research should examine system engineering designs for system requirements traceability matrix of mission tasks and subtasks while using an analysis tool that adequately evaluates UASs with an acceptable level of confidence in the results.
ERIC Educational Resources Information Center
Pinder, Glen T.
2017-01-01
In today's world of accountability, the preparation of school leaders has never been more critical. Many states are now developing policies and processes that seek to enhance school leadership preparation programs. Enhancing school leadership preparation programs is particularly important in the area of instructional leadership because research…
Application of a Network Perspective to DoD Weapon System Acquisition: An Exploratory Study
2007-04-30
the course of action, and prepare for the Technology Development phase. As one could guess based on the description of...include allocating requirements and developing a design, testing the design, and preparing for production and fielding of the system. This analysis...Management and Budget (OMB) prepare the defense portion of the President’s Budget. Even though Congress normally appropriates money for only
ERIC Educational Resources Information Center
Yu, Guoxing; He, Lianzhen; Rea-Dickins, Pauline; Kiely, Richard; Lu, Yanbin; Zhang, Jing; Zhang, Yan; Xu, Shasha; Fang, Lin
2017-01-01
Language test preparation has often been studied within the consequential validity framework in relation to ethics, equity, fairness, and washback of assessment. The use of independent and integrated speaking tasks in the "TOEFL iBT"® test represents a significant development and innovation in assessing speaking ability in academic…
PM-1 NUCLEAR POWER PLANT PROGRAM. Quarterly Progress Report No. 2 for June 1 to August 31, 1959
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sieg, J.S.; Smith, E.H.
1959-10-01
The objective of the contract is the design, development, fabrication, installation, and initial testing and operation of a prepackaged air- transportable pressurized water reactor nuclear power plant, the PM-1. The specified output is 1 Mwe and 7 million Btu/hr of heat. The plant is to be operational by March 1962. The principal efforts were completion of the plant parametric study and preparation of the preliminary design. A summary of design parameters is given. Systems development work included study and selection of packages for full-scale testing, a survey of in-core instrumentation techniques, control and instrumentation development, and development of components formore » the steam generator, condenser, and turbine generator, which are not commercially available. Reactor development work included completion of the parametric zeropower experiments and preparrtions for a flexible zeropower test program, a revision of plans for irradiation testing PM-1 fuel elements, initiation of a reactor flow test program, outliring of a heat tnansfer test program, completion of the seven-tube test section (SETCH-1) tests, and evaluation of control rod actuators leading to specification of a magnetic jack-type control rod drive similar to that reported in ANL-5768. Completion of the prelimirary design led to initiation of the final design effort, which will be the principal activity during the next two project quarters. Preparations for core fabrication included procurement of core cladding material for the zero-power teat core, arrangement with a subcontractor to convent UF/sub 6/ to UO/sub 2/ and to commence delivery of the oxide during the next quarter, development of fuel element fabrication and ultrasonic testing techniques, study of control rod materials, UO/sub 2/ recovery techniques, and boron analysis methods. Preliminary work on site preparation was pursued with receipt of USAEC approval for a location on the eastern slope of Warren Peak at Sundance, Wyoming. A survey of this site is underway. A preliminary Hazards Summary Report is in preparation. (For preceding period see MND-M-1812.) (auth)« less
New method for rapid testing of bond strength for wood adhesives
James M. Wescott; Michael J. Birkeland; Amy E. Traska; Charles R. Frihart; Brice N. Dally
2007-01-01
In developing new adhesives for wood bonding, the testing of bond performance can often be a limiting factor in the development process. Evaluating the bond performance of an adhesive that can be prepared in less than a day often takes several days using standard performance tests. This testing slows the development process and may cause a company to abandon a...
Using Corpora in EFL Classrooms: The Case Study of IELTS Preparation
ERIC Educational Resources Information Center
Smirnova, Elizaveta A.
2017-01-01
This article describes the gathered experience in using corpora in an IELTS preparation course. The practice demonstrates an attempt to reduce negative washback effects occurring when preparation courses just concentrate on the test format neglecting the importance of development of learners' language skills and general study skills. Some…
Quantum efficiency test set up performances for NIR detector characterization at ESTEC
NASA Astrophysics Data System (ADS)
Crouzet, P.-E.; Duvet, L.; De Wit, F.; Beaufort, T.; Blommaert, S.; Butler, B.; Van Duinkerken, G.; ter Haar, J.; Heijnen, J.; van der Luijt, K.; Smit, H.; Viale, T.
2014-07-01
The Payload Technology Validation Section (Future mission preparation Office) at ESTEC is in charge of specific mission oriented validation activities, for science and robotic exploration missions, aiming at reducing development risks in the implementation phase. These activities take place during the early mission phases or during the implementation itself. In this framework, a test set up to characterize the quantum efficiency of near infrared detectors has been developed. The first detector to be tested will an HAWAII-2RG detector with a 2.5μm cut off, it will be used as commissioning device in preparation to the tests of prototypes European detectors developed under ESA funding. The capability to compare on the same setup detectors from different manufacturers will be a unique asset for the future mission preparation office. This publication presents the performances of the quantum efficiency test bench to prepare measurements on the HAWAII-2RG detector. A SOFRADIR Saturn detector has been used as a preliminary test vehicle for the bench. A test set up with a lamp, chopper, monochromator, pinhole and off axis mirrors allows to create a spot of 1mm diameter between 700nm and 2.5μm.The shape of the beam has been measured to match the rms voltage read by the Merlin Lock -in amplifier and the amplitude of the incoming signal. The reference detectors have been inter-calibrated with an uncertainty up to 3 %. For the measurement with HAWAII-2RG detector, the existing cryostat [1] has been modified to adapt cold black baffling, a cold filter wheel and a sapphire window. An statistic uncertainty of +/-2.6% on the quantum efficiency on the detector under test measurement is expected.
Development and operations of the Astrophysics Data System
NASA Technical Reports Server (NTRS)
Murray, S. S.
1993-01-01
The main effort in October 1992 was for the development and of the Astrophysics Data System (ADS) 3.1 graphical interface (GUI) and the preparation for its release. The beta-release for the GUI was made available to the nodes for testing. Development of the Abstract Server progressed satisfactorily. A test version was prepared for the ADASS meeting. Another major effort was the preparation for the user and nodes meetings on 5 and 6 November and for the ADASS conference on 2-4 November. February 1993 was highlighted by the preparation for the update release and its associated problems. We have the okay from the Commerce Department to export ADS. Foreign users can now sign on and receive the software. The main event during June was the AAS meeting. In the summer, the project decided on a new release schedule. The next major release is scheduled for January 1994 and will include major architectural improvements. In late spring 1994, a major release will include the new networking software.
Zhang, Heng; Lan, Fang; Shi, Yupeng; Wan, Zhi-Gang; Yue, Zhen-Feng; Fan, Fang; Lin, Yan-Kui; Tang, Mu-Jin; Lv, Jing-Zhang; Xiao, Tan; Yi, Changqing
2014-06-15
VitaFast(®) test kits designed for the microbiological assay in microtiter plate format can be applied to quantitative determination of B-group water-soluble vitamins such as vitamin B12, folic acid and biotin, et al. Compared to traditional microbiological methods, VitaFast(®) kits significantly reduce sample processing time and provide greater reliability, higher productivity and better accuracy. Recently, simultaneous determination of vitamin B12, folic acid and biotin in one sample is urgently required when evaluating the quality of infant formulae in our practical work. However, the present sample preparation protocols which are developed for individual test systems, are incompatible with simultaneous determination of several analytes. To solve this problem, a novel "three-in-one" sample preparation method is herein developed for simultaneous determination of B-group water-soluble vitamins using VitaFast(®) kits. The performance of this novel "three-in-one" sample preparation method was systematically evaluated through comparing with individual sample preparation protocols. The experimental results of the assays which employed "three-in-one" sample preparation method were in good agreement with those obtained from conventional VitaFast(®) extraction methods, indicating that the proposed "three-in-one" sample preparation method is applicable to the present three VitaFast(®) vitamin test systems, thus offering a promising alternative for the three independent sample preparation methods. The proposed new sample preparation method will significantly improve the efficiency of infant formulae inspection. Copyright © 2013 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bartke, T.C.
Under the US Department of Energy's Underground-Coal-Conversion program, four field tests were completed in 1979 and preparations were begun in 1980 for two additional field tests to be operated in 1981. The Laramie Energy Technology Center (LETC) and Sandia National Laboratories (SNL) completed Hanna IV, an air gasification test in Wyoming subbituminous coal. The Morgantown Energy Technology Center (METC) completed Pricetown 1, an air gasification test in West Virginia bituminous coal. Lawrence Livermore National Laboratory (LLNL) completed Hoe Creek 3, a steam-oxygen gasification test in Wyoming subbituminous coal. Gulf Research and Development Co. completed Steeply Dipping Beds (SDB) Test 1,more » primarily an air gasification test in Wyoming subbituminous coal and the first SDB test in the US. In 1980, Gulf R and D Co. began preparation of SDB Test 2, scheduled for operation in the fall of 1981. The DOE project teams at LETC, METC, LLNL, and SNL, in association with the Washington Irrigation and Development Co. (WIDCo), Washington Water Power (WWP), and the State of Washington, are preparing a field test site in the Centralia-Chehalis coal district of Washington. A series of large coal block tests will be completed prior to the field test, scheduled for operation in 1982 or 1983. This field test will utilize a directionally drilled link and steam-oxygen gasification system. This paper summarizes the results of the four recently completed field tests and the plans for additional tests.« less
Mathew, Joe; Kurian, Byju P; Philip, Biju; Mohammed, Sunil; Menon, Preetha; Raj, Rajan S
2016-08-01
Superior adhesive strength in luting agents is of paramount significance in fixed partial denture success. In this in vitro study five cements were tested for retentive qualities, using both lathe-cut and hand-prepared specimens. A total of 104 freshly extracted tooth specimens were prepared. Seventy of them were lathe-cut and 30 specimens were hand-prepared to simulate clinical conditions. Five different cements were tested, which included a compomer, a composite, a zinc phosphate, and 2 glass-ionomer luting cements. Of the 5, 2 trial cements were indigenously developed by Sree Chitra Tirunal Institute for Medical Sciences and Technology (SCTIMST), Trivandrum, India - a glass-ionomer cement (Chitra GIC) and a chemical-cure composite (Chitra CCC). All cements were compared within each group and between groups (lathe-prepared and hand-prepared). GC Fuji 1 (GC America) exhibited superior retentive strengths in both lathe-cut and hand-prepared specimens, whereas the compomer cement displayed the lowest values when tested. In lathe-cut specimens, statistical analysis showed no significant difference between GC Fuji 1 and indigenously developed Chitra CCC. Both Chitra CCC and GC Fuji 1 have comparable strengths in lathe-cut samples, making Chitra CCC a potential luting agent. Statistical analysis reveals that all cements, except GC Fuji 1, exhibited a significant decrease in strength due to the change in design uniformity. The chemical bonding of GC Fuji 1 proves to be quite strong irrespective of shape and precision of the tooth crown. The indigenously developed Chitra GIC and Chitra CCC showed promising results to be used as a potential luting agent.
Deconinck, E; Crevits, S; Baten, P; Courselle, P; De Beer, J
2011-04-05
A fully validated UHPLC method for the identification and quantification of folic acid in pharmaceutical preparations was developed. The starting conditions for the development were calculated starting from the HPLC conditions of a validated method. These start conditions were tested on four different UHPLC columns: Grace Vision HT™ C18-P, C18, C18-HL and C18-B (2 mm × 100 mm, 1.5 μm). After selection of the stationary phase, the method was further optimised by testing two aqueous and two organic phases and by adapting to a gradient method. The obtained method was fully validated based on its measurement uncertainty (accuracy profile) and robustness tests. A UHPLC method was obtained for the identification and quantification of folic acid in pharmaceutical preparations, which will cut analysis times and solvent consumption. Copyright © 2010 Elsevier B.V. All rights reserved.
ATE/ICEPM Development Report and Function Demonstration Test.
1975-01-01
DTfC JANUARY 1975 S U gl CONTRACT NO. DAAE07-73-C-0268 F - - -- - - b,,-4, i .y TRW SYSTEMS GROUP D - PROPULSION SYSTEMS LABORATORY t 82 07 22 067 II i ...DEMONSTRATION TEST FINAL REPORT Contract No. DAAEO7-73--C-0268 XccessiOf Yor U~ ultis. GFA& I copy~ t e!A C3 PY;E lilannoQ*C~INSPECTED otIo - Prepared by Bye...program L o Improvement of system hardware I o Preparation of systems support material 2.1 Development of the Diagnostic Engineering Structure The
1978-09-01
iE ARI TECHNICAL REPORT S~ TR-78-A31 M CCriterion-Reforencod Loasurement In the Army: Development of a Research-Based, Practical, Test Construction ...conducted to develop a Criterion- 1 Referenced Tests (CRTs) Construction Manual. Major accomplishments were the preparation of a written review of the...survey of the literature on Criterion-Referenced Testing’ conducted in order to provide an information base for development of the CRT Construction
Preparation of refractory cermet structures for lithium compatibility testing
NASA Technical Reports Server (NTRS)
Heestand, R. L.; Jones, R. A.; Wright, T. R.; Kizer, D. E.
1973-01-01
High-purity nitride and carbide cermets were synthesized for compatability testing in liquid lithium. A process was developed for the preparation of high-purity hafnium nitride powder, which was subsequently blended with tungsten powder or tantalum nitride and tungsten powders and fabricated into 3 in diameter billets by uniaxial hot pressing. Specimens were then cut from the billets for compatability testing. Similar processing techniques were applied to produce hafnium carbide and zirconium carbide cermets for use in the testing program. All billets produced were characterized with respect to chemistry, structure, density, and strength properties.
Stevanović, M; Cadez, P; Zlender, B; Filipic, M
2000-07-01
The preformed cooked cured meat pigment (CCMP) synthesized directly from bovine red blood cells or through a hemin intermediate was found to be a viable colorant for application to comminuted pork as a nitrite substitute. However the genotoxicity of CCMP and meat emulsion coagulates prepared with CCMP has not been evaluated. Therefore the objectives of this work were to investigate genotoxicity of CCMP and the influence of CCMP addition on genotoxicity and the content of residual nitrite in model meat emulsion coagulates. Meat emulsions were prepared from white (musculus longissimus dorsi) and red (musculus quadriceps femoris) pork muscles with two different amounts of synthesized pigment CCMP. Comparatively, emulsions with fixed addition of nitrite salt and emulsions without any addition for color development were made. Genotoxicity of CCMP and meat emulsion coagulates was tested with the SOS/umu test and the Ames test. Neither CCMP nor meat emulsion coagulates prepared with CCMP or nitrite salt were genotoxic in the SOS/umu test. In the Ames test using Salmonella Typhimurium strains TA98 and TA100 samples of coagulates prepared with CCMP and with nitrite showed weak mutagenic activity in Salmonella Typhimurium strain TA100 but only in the absence of the metabolic activation, while CCMP was not mutagenic. Coagulates prepared with CCMP contained significantly less residual nitrite than coagulates prepared with nitrite salt. These results indicate that from the human health standpoint the substitution of nitrite salt with CCMP would be highly recommendable.
Study of development and utilization of a multipurpose atmospheric corrosion sensor
NASA Technical Reports Server (NTRS)
Diwan, Ravinder M.; Raman, A.; Bhattacharya, P. K.
1994-01-01
There has been a critical need for analyzing various aspects of atmospheric corrosion and for the development of atmospheric corrosion microsensors. The project work has involved the following activities: (1) making of multielectrode corrosion monitors on dielectric substrates; (2) testing them in the laboratory for functional characteristics; (3) preparing a report on the state of the art of atmospheric corrosion sensor development around the world; and (4) corrosion testing of electrochemical changes of sensor specimens and related fog testing. The study included work on the subject of development and utilization of a multipurpose atmospheric corrosion sensor and this report is the annual report on work carried out on this research project. This has included studies on the development of sensors of two designs, stage 1 and stage 2, and with glass and alumina substrate, experimentation and development and characterization of the coating uniformity, aspects of corrosion monitoring, literature search on the corrosion sensors and their development. A state of the art report on atmospheric corrosion sensor development was prepared and submitted.
Development of a Work Control System for Propulsion Testing at Stennis Space Center (SSC)
NASA Technical Reports Server (NTRS)
Messer, Elizabeth A.
2004-01-01
In 1996, Stennis Space Center was given management authority for all Propulsion Testing for NASA. Over the next few years several research and development (R&D) test facilities were completed and brought up to full operation in what is known as the E-Complex Test Facility at Stennis Space Center. This paper will explain the requirements and steps taken to develop the current Test Operations' electronic work control system. The Work Control System developed includes work authorization documents such as test preparation sheets, discrepancy reports, pre-test briefing reports, and test requests.
Limited electromagnetic interference testing of evidential breath testers
DOT National Transportation Integrated Search
1983-05-06
This report summarizes a limited test program conducted to determine the susceptibility of evidential breath testers (EBTs) to radio frequency interference (RFI). Several comprehensive test protocols were prepared based on procedures developed by the...
2008-01-24
NASA Dryden technicians work on a fit-check mockup in preparation for systems installation work on an Orion boilerplate crew capsule for launch abort testing. A mockup Orion crew module has been constructed by NASA Dryden Flight Research Center's Fabrication Branch. The mockup is being used to develop integration procedures for avionics and instrumentation in advance of the arrival of the first abort flight test article.
Advanced manufacturing development of a composite empennage component for L-1011 aircraft
NASA Technical Reports Server (NTRS)
1979-01-01
Work on process verification and tooling development continued. The cover process development was completed with the decision to proceed with low resin content prepreg material (34 + or - 3% by weight) in the fabrication of production readiness verification test (PRVT) specimens and the full-scale covers. The structural integrity of the cover/joint design was verified with the successful test of the cover attachment to fuselage ancillary test specimen (H25). Failure occurred, as predicted, in the skin panel away from the fuselage joint at 141 percent of the design ultimate load. With the successful completion of the H25 test, the PRVT cover specimens, which are identical to the H25 ancillary test specimen, were cleared for production. Eight of the twenty cover specimens were fabricated and are in preparation for test. All twenty of the PRVT spar specimens were fabricated and also were prepared for test. The environmental chambers used in the durability test of ten cover and ten spar PRVT specimens were completed and installed in the load reaction frames.
Instruments for preparation of heterogeneous catalysts by an impregnation method
NASA Astrophysics Data System (ADS)
Yamada, Yusuke; Akita, Tomoki; Ueda, Atsushi; Shioyama, Hiroshi; Kobayashi, Tetsuhiko
2005-06-01
Instruments for the preparation of heterogeneous catalysts in powder form have been developed. The instruments consist of powder dispensing robot and an automated liquid handling machine equipped with an ultrasonic and a vortex mixer. The combination of these two instruments achieves the catalyst preparation by incipient wetness and ion exchange methods. The catalyst library prepared with these instruments were tested for dimethyl ether steam reforming and characterized by transmission electron microscopy observations.
Inspection authorization knowledge test guide : 1996.
DOT National Transportation Integrated Search
1996-01-01
This knowledge test guide was developed to be used by applicants preparing to take the Inspection Authorization : Knowledge Test on the computer. : The FAA initiated the issuance of the Inspection Authorization more than 35 years ago. This system of ...
IDC Re-Engineering Phase 3 Development Plan.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harris, James M.; Burns, John F.; Pollock, David L.
2017-01-01
Sandia National Laboratories has prepared a project development plan that proposes how the parties interested in the IDC Re-Engineering system will coordinate its development, testing and transition to operations.
Early Phonological Development: Creating an Assessment Test
ERIC Educational Resources Information Center
Stoel-Gammon, Carol; Williams, A. Lynn
2013-01-01
This paper describes a new protocol for assessing the phonological systems of two-year-olds with typical development and older children with delays in vocabulary acquisition. The test (Profiles of Early Expressive Phonological Skills ("PEEPS"), Williams & Stoel-Gammon, in preparation) differs from currently available assessments in…
Development of Dietary Polyphenol Preparations for Treating Veterans with Gulf War Illness
2015-10-01
chronic fatigue. We hypothesized that dietary supplementation with a Flavonoid- Rich Preparation (FRP), a combination of Concord Grape Juice (CGJ...We propose to test the feasibility of dietary supplementation with FRP in Veterans with GWI, and to gather evidence supporting the efficacy of FRP...fatigue and preserve against cognitive functions. Based on this, our overall goal is to test the potential efficacy of dietary supplementation with a
A Novel Preparation Method of Two Polymer Dyes with Low Cytotoxicity
Lv, Dongjun; Zhang, Mingjie; Cui, Jin; Li, Weixue; Zhu, Guohua
2017-01-01
A new preparation method of polymer dyes was developed to improve both the grafting degree of the azo dyes onto O-carboxymethyl chitosan (OMCS) and the water solubility of prepared polymer dyes. Firstly, the coupling compound of two azo edible colorants, sunset yellow (SY) and allura red (AR), was grafted onto OMCS, and then coupled with their diazonium salt. The chemical structure of prepared polymer dyes was determined by Fourier transform-infrared spectroscopy and 1H-NMR, and the results showed that the two azo dyes were successfully grafted onto OMCS. The grafting degree onto OMCS and the water solubility of polymer dyes were tested, and the results showed that they were both improved as expected. The UV-vis spectra analysis results showed that the prepared polymer dyes showed similar color performance with the original azo dyes. Eventually, the cytotoxicity of prepared polymer dyes was tested and compared with the original azo dyes by a cytotoxicity test on human liver cell lines LO2, and the results showed that their grafting onto OMCS significantly reduced the cytotoxicity. PMID:28772583
Pharmaceutical and analytical evaluation of triphalaguggulkalpa tablets
Savarikar, Shreeram S.; Barbhind, Maneesha M.; Halde, Umakant K.; Kulkarni, Alpana P.
2011-01-01
Aim of the Study: Development of standardized, synergistic, safe and effective traditional herbal formulations with robust scientific evidence can offer faster and more economical alternatives for the treatment of disease. The main objective was to develop a method of preparation of guggulkalpa tablets so that the tablets meet the criteria of efficacy, stability, and safety. Materials and Methods: Triphalaguggulkalpa tablet, described in sharangdharsanhita and containing guggul and triphala powder, was used as a model drug. Preliminary experiments on marketed triphalaguggulkalpa tablets exhibited delayed in vitro disintegration that indicated probable delayed in vivo disintegration. The study involved preparation of triphalaguggulkalpa tablets by Ayurvedic text methods and by wet granulation, dry granulation, and direct compression method. The tablets were evaluated for loss on drying, volatile oil content, % solubility, and steroidal content. The tablets were evaluated for performance tests like weight variation, disintegration, and hardness. Results: It was observed that triphalaguggulkalpa tablets, prepared by direct compression method, complied with the hardness and disintegration tests, whereas tablets prepared by Ayurvedic text methods failed. Conclusion: Direct compression is the best method of preparing triphalaguggulkalpa tablets. PMID:21731383
Nickerson, Beverly; Harrington, Brent; Li, Fasheng; Guo, Michele Xuemei
2017-11-30
Drug product assay is one of several tests required for new drug products to ensure the quality of the product at release and throughout the life cycle of the product. Drug product assay testing is typically performed by preparing a composite sample of multiple dosage units to obtain an assay value representative of the batch. In some cases replicate composite samples may be prepared and the reportable assay value is the average value of all the replicates. In previously published work by Harrington et al. (2014) [5], a sample preparation composite and replicate strategy for assay was developed to provide a systematic approach which accounts for variability due to the analytical method and dosage form with a standard error of the potency assay criteria based on compendia and regulatory requirements. In this work, this sample preparation composite and replicate strategy for assay is applied to several case studies to demonstrate the utility of this approach and its application at various stages of pharmaceutical drug product development. Copyright © 2017 Elsevier B.V. All rights reserved.
Inductive interference in rapid transit signaling systems. volume 2. suggested test procedures.
DOT National Transportation Integrated Search
1987-03-31
These suggested test procedures have been prepared in order to develop standard methods of analysis and testing to quantify and resolve issues of electromagnetic compatibility in rail transit operations. Electromagnetic interference, generated by rai...
Report on Development and Evaluation of a Self-Study Course for Adult Four-H Leaders.
ERIC Educational Resources Information Center
Neidt, Charles O.
This programed instruction project for adult Four-H leaders was undertaken to develop a ten unit manuscript covering basic Four H concepts; to prepare four versions thereof differing in response mode; to field test all four on a national sample of leaders; and to prepare a final research edition of the course based on the response mode proving…
SRB Processing Facilities Media Event
2016-03-01
Members of the news media view the high bay inside the Rotation, Processing and Surge Facility (RPSF) at NASA’s Kennedy Space Center in Florida. Kerry Chreist, with Jacobs Engineering on the Test and Operations Support Contract, explains the various test stands and how they will be used to prepare booster segments for NASA’s Space Launch System (SLS) rocket. In the far corner, in the vertical position, is one of two pathfinders, or test versions, of solid rocket booster segments for the SLS rocket. The Ground Systems Development and Operations Program and Jacobs are preparing the booster segments, which are inert, for a series of lifts, moves and stacking operations to prepare for Exploration Mission-1, deep-space missions and the journey to Mars.
Hospital preparedness for Ebola virus disease: a training course in the Philippines
Carlos, Celia; Capistrano, Rowena; Tobora, Charissa Fay; delos Reyes, Mari Rose; Lupisan, Socorro; Corpuz, Aura; Aumentado, Charito; Suy, Lyndon Lee; Hall, Julie; Donald, Julian; Counahan, Megan; Curless, Melanie S; Rhymer, Wendy; Gavin, Melanie; Lynch, Chelsea; Black, Meredith A; Anduyon, Albert D; Buttner, Petra
2015-01-01
Objective To develop, teach and evaluate a training workshop that could rapidly prepare large numbers of health professionals working in hospitals in the Philippines to detect and safely manage Ebola virus disease (EVD). The strategy was to train teams (each usually with five members) of key health professionals from public, private and local government hospitals across the Philippines who could then guide Ebola preparedness in their hospitals. Methods The workshop was developed collaboratively by the Philippine Department of Health and the country office of the World Health Organization. It was evaluated using a pre- and post-workshop test and two evaluation forms. χ2 tests and linear regression analyses were conducted comparing pre- and post-workshop test results. Results A three-day workshop was developed and used to train 364 doctors, nurses and medical technologists from 78 hospitals across the Philippines in three initial batches. Knowledge about EVD increased significantly (P < 0.009) although knowledge on transmission remained suboptimal. Confidence in managing EVD increased significantly (P = 0.018) with 96% of participants feeling more prepared to safely manage EVD cases. Discussion: The three-day workshop to prepare hospital staff for EVD was effective at increasing the level of knowledge about EVD and the level of confidence in managing EVD safely. This workshop could be adapted for use as baseline training in EVD in other developing countries to prepare large numbers of hospital staff to rapidly detect, isolate and safely manage EVD cases. PMID:25960920
Development of Dietary Polyphenol Preparations for Treating Veterans with Gulf War Illness
2016-10-01
chronic fatigue. We hypothesized that dietary supplementation with a Flavonoid Rich Preparation (FRP), a combination of Concord Grape Juice (CGJ) and...We propose to test the feasibility of dietary supplementation with FRP in Veterans with GWI, and to gather evidence supporting the efficacy of FRP in...fatigue and preserve against cognitive functions. Based on this, our overall goal is to test the potential efficacy of dietary supplementation with a
1985-06-01
of chemical analysis and sensitivity testing on material samples . At this 4 time, these samples must be packaged and...preparation at a rate of three samples per hour. One analyst doing both sample preparation and the HPLC analysis can run 16 samples in an 8-hour day. II... study , sensitivity testing was reviewed to enable recommendations for complete analysis of contaminated soils. Materials handling techniques,
Research of metal solidification in zero-g state. [test apparatus and instrumentation
NASA Technical Reports Server (NTRS)
Aubin, W. M.; Larson, D., Jr.; Geschwind, G. I.
1973-01-01
An experiment test apparatus that allows metal melting and resolidification in the three seconds available during free fall in a drop tower was built and tested in the tower. Droplets (approximately 0.05 cm) of pure nickel and 1090 steel were prepared in this fashion. The apparatus, including instrumentation, is described. As part of the instrumentation, a method for measuring temperature-time histories of the free floating metal droplets was developed. Finally, a metallurgical analysis of the specimens prepared in the apparatus is presented.
Involving Students in Developing Math Tests
ERIC Educational Resources Information Center
Rapke, Tina
2017-01-01
Many studies have claimed that traditional testing actually promotes students' use of superficial approaches to learning. When preparing to take tests, students typically memorize and cram rather than understanding the material and gaining new perspectives. This article describes how the author recast traditional tests by having students take a…
Scholastic Aptitude Test Preparation for the Adolescent Dyslexic.
ERIC Educational Resources Information Center
Rothschild, Lois H.
1987-01-01
Scholastic Aptitude Test skills of dyslexics can be enhanced through use of special test administration arrangements and a structured program of vocabulary development, test-taking strategies, and a pattern of analysis to improve reading comprehension. Two case studies illustrate the impact of drill and reinforcement, multimodal imagery…
The Florida State Initial Teacher Certification Test: A Case Study.
ERIC Educational Resources Information Center
Dorn, Charles M.
1989-01-01
Describes the development of the art certification examination which was designed for the Florida State Initial Teacher Certification Test. Discusses problems of subjectivity, content, and question format. Suggests criteria which can guide the development of viable college art education programs that can adequately prepare teachers in the areas of…
Effect of Hypertextual Reading on Academic Success and Comprehension Skills
ERIC Educational Resources Information Center
Durukan, Erhan
2014-01-01
As computer technology developed, hypertexts emerged as an influential environment for developing language skills. This study aims to evaluate a text prepared in a hypertextual environment and its effects on academic success and comprehension skills. In this study, "preliminary test final test control group experimental pattern" was used…
Hiebl, Bernhard; Lützow, Karola; Lange, Maik; Jung, Friedrich; Seifert, Barbara; Klein, Frank; Weigel, Thomas; Kratz, Karl; Lendlein, Andreas
2010-07-01
Most polymers used in clinical applications today are materials that have been developed originally for application areas other than biomedicine. Testing the cell- and tissue-compatibility of novel materials in vitro and in vivo is of key importance for the approval of medical devices and is regulated according to the Council Directive 93/42/EEC of the European communities concerning medical devices. In the standardized testing methods the testing sample is placed in commercially available cell culture plates, which are often made from polystyrene. Thus not only the testing sample itself influences cell behavior but also the culture vessel material. In order to exclude this influence, a new system for cell testing will be presented allowing a more precise and systematic investigation by preparing tailored inserts which are made of the testing material. Inserts prepared from polystyrene, polycarbonate and poly(ether imide) were tested for their cytotoxity and cell adherence. Furthermore a proof of principle concerning the preparation of inserts with a membrane-like surface structure and its surface modification was established. Physicochemical investigations revealed a similar morphology and showed to be very similar to the findings to analogous preparations and modifications of flat-sheet membranes. Copyright (c) 2010 Elsevier B.V. All rights reserved.
Testing Teacher Candidates: The Role of Licensure Tests in Improving Teacher Quality.
ERIC Educational Resources Information Center
Mitchell, Karen J., Ed.; Robinson, David Z., Ed.; Plake, Barbara S., Ed.; Knowles, Kaeli T., Ed.
This book examines the appropriateness and technical quality of teacher licensure tests currently in use, evaluating teacher licensure tests and examining the use of tests to hold states and institutions of higher education accountable for the quality of teacher preparation and licensure. It also suggests alternatives for developing and assessing…
Mathematics: Algebra and Geometry. GED Scoreboost.
ERIC Educational Resources Information Center
Hoyt, Cathy
GED "Scoreboost" materials target exactly the skills one needs to pass the General Educational Development (GED) tests. This book focuses on the GED Mathematics test. To prepare for the test, the test taker needs to learn skills in number and operation sense, data and statistics, geometry and measurement, and algebra. To pass the test,…
Teach Reading, Not Testing: Best Practice in an Age of Accountability
ERIC Educational Resources Information Center
Hollingworth, Liz; Drake, Hilleary M.
2011-01-01
"Teach Reading, Not Testing" reinforces what teachers already know--test preparation worksheets and drill-and-kill activities do not make children into lifelong readers. The authors' conscientious approach to reading instruction combines an insider perspective on the development of high-stakes tests with classroom experience in achieving…
A study for hypergolic vapor sensor development
NASA Technical Reports Server (NTRS)
Stetter, J. R.; Tellefsen, K.
1977-01-01
In summary, the following tasks were completed within the scope of this work: (1) a portable Monomethylhydrazine analyzer was developed, designed, fabricated and tested. (2) A portable NO2 analyzer was developed, designed, fabricated and tested. (3) Sampling probes and accessories were designed and fabricated for this instrumentation. (4) Improvements and modifications were made to the model 7630 Ecolyzer in preparation for field testing. (5) Instrument calibration procedures and hydrazine handling techniques necessary to the successful application of this hardware were developed.
Pegasus Rocket Booster Being Prepared for X-43A/Hyper-X Flight Test
1999-08-25
Technicians prepare a Pegasus rocket booster for flight tests with the X-43A "Hypersonic Experimental Vehicle," or "Hyper-X." The X-43A, which will be attached to the Pegasus booster and drop launched from NASA's B-52 mothership, was developed to research dual-mode ramjet/scramjet propulsion system at speeds from Mach 7 up to Mach 10 (7 to 10 times the speed of sound, which varies with temperature and altitude).
NASA Technical Reports Server (NTRS)
Gilligan, J. E.; Harada, Y.
1974-01-01
The development of a large scale manufacturing method for the production of a stable zinc orthotitanate pigment is discussed. Major emphasis was placed on the evaluation of ultraviolet radiation stability tests of pigments derived from coprecipitated and individually precipitated oxalates. Emphasis was also placed on an investigation of the conditions (time and temperature) leading to high reflectance and high optical stability. Paints were formulated in OI-650 and in OI-650G vehicles from pigments which were prepared at various temperatures. Analyses of ultraviolet irradiation test data were conducted regarding optimum pigment preparation parameters and treatment conditions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Belles, Randy; Flanagan, George F.; Voth, Marcus
Development of non-power molten salt reactor (MSR) test facilities is under consideration to support the analyses needed for development of a full-scale MSR. These non-power MSR test facilities will require review by the US Nuclear Regulatory Commission (NRC) staff. This report proposes chapter adaptations for NUREG-1537 in the form of interim staff guidance to address preparation and review of molten salt non-power reactor license applications. The proposed adaptations are based on a previous regulatory gap analysis of select chapters from NUREG-1537 for their applicability to non-power MSRs operating with a homogeneous fuel salt mixture.
Food Preparation and Service: Cluster Guide.
ERIC Educational Resources Information Center
Central Michigan Univ., Mount Pleasant.
This teacher's guide is one of a series of publications focusing on the occupational preparation of persons with special education needs. The material was developed and tested by cooperating teachers over a period of three years. Task analysis information is presented using occupational descriptions from the Dictionary of Occupational Titles,…
Research and development support for the Center for Seismic Studies
NASA Astrophysics Data System (ADS)
Romney, C. F.; Huszar, L.; Frazier, G. A.
1984-07-01
Work during the second and third quarters of FY1984 continued to be focused on the development of the Center for Seismic Studies, and on planning and developments to prepare for a test of Seismic data exchange and event determination, as proposed by the group of Scientific Experts, UN Committee on Disarmament. A help system was designed and partially completed, and other aids for new users of the Center's data and facilities were developed. An introduction to Ingres was prepared, and new experimental data bases were installed.
Bibliography of In-House and Contract Reports, Supplement 18
1992-10-01
Transparent Conforming Overlays 46 TITLE REPORT NO. YEAR Development, Service Tests, and Production Model 1307 -TR 1953 Tests, Autofocusing Rectifier...Development, Test, Preparation, Delivery, and ETL- 1307 1982 Installation of Algorithms for Optimal Adjustment of Inertial Survey Data Developmental Optical...B: Terrain ETL- 0428 1986 and Object Modeling Recognition (March 13, 1985 - March 13, 1986) Knowledge-Based Vision Techniques - Task B: Terrain ETL
Guidelines on Pilot and Field Testing of Curriculum Products.
ERIC Educational Resources Information Center
Contract Research Corp., Belmont, MA.
This booklet is intended to aid curriculum developers in designing and conducting pilot or field tests that yield useful information and sound evidence about the effectiveness of new curricula. Although it was prepared specifically for use by projects funded by the Curriculum Development Branch of the federal Bureau of Occupational and Adult…
Development and Preparation of Lead-Containing Paint Films and Diagnostic Test Materials
Lead in paint continues to be a threat to children’s health in cities across the United States, which means there is an ongoing need for testing and analysis of paint. This ongoing analytical effort and especially development of new methods continue to drive the need for diagnost...
Toddler test or procedure preparation
Preparing toddler for test/procedure; Test/procedure preparation - toddler; Preparing for a medical test or procedure - toddler ... Before the test, know that your child will probably cry. Even if you prepare, your child may feel some discomfort or ...
Begnini, Fernanda R; Jardim, Isabel C S F
2013-07-05
A new reversed phase high-performance liquid chromatography (RP-HPLC) stationary phase was prepared and its chromatographic and physical-chemical properties were evaluated. The new stationary phase was prepared with a silica support and poly(2-phenylpropyl)methylsiloxane (PPPMS), a phenyl type polysiloxane copolymer. Since this is a new copolymer and there is little information in the literature, it was submitted to physical-chemical characterization by infrared spectroscopy and thermogravimetry. The chromatographic phase was prepared through sorption and microwave immobilization of the copolymer onto a silica support. The chromatographic performance was evaluated by employing test procedures suggested by Engelhardt and Jungheim, Tanaka and co-workers, Neue, and Szabó and Csató. These test mixtures provide information about the hydrophobic selectivity, silanophilic activity, ion-exchange capacity, shape selectivity and interaction with polar analytes of the new Si-PPPMS reversed phase. Stability tests were developed using accelerated aging tests under both basic and acidic conditions to provide information about the lifetime of the packed columns. Copyright © 2013 Elsevier B.V. All rights reserved.
SRB Processing Facilities Media Event
2016-03-01
Members of the news media watch as a crane is used to move one of two pathfinders, or test versions, of solid rocket booster segments for NASA’s Space Launch System rocket to a test stand in the Rotation, Processing and Surge Facility at NASA’s Kennedy Space Center in Florida. Inside the RPSF, the Ground Systems Development and Operations Program and Jacobs Engineering, on the Test and Operations Support Contract, will prepare the booster segments, which are inert, for a series of lifts, moves and stacking operations to prepare for Exploration Mission-1, deep-space missions and the journey to Mars.
Ketefian, S
1981-01-01
The focus of this descriptive study was the relationship between critical thinking, educational preparation, and level of moral judgment in 79 practicing nurses. The Watson-Glaser Critical Thinking Appraisal Test was used to measure critical thinking; information on the participating nurses' educational preparation was obtained from a personal information sheet. Moral judgment was measured by Rest's Defining Issues Test. The hypothesis that critical thinking would be positively related to moral judgment was tested by Pearson product moment correlation; the obtained coefficient of .5326 was significant at the .001 level. The hypothesis that there would be a difference between professional and technical nurses' moral judgments was tested through a one-way analysis of variance. The F ratio (F [1,77] = 9.6) was significant beyond the .01 level. Data also supported the hypothesis that critical thinking and educational preparation would predict greater variance in moral judgment than either variable alone, which was tested through multiple regression analysis (F [2,75] = 18.3, p = .01). Critical thinking and education together accounted for 32.9 percent of the variance in moral judgment. Implications of the findings are discussed for nursing research, practice, and education.
Thin-film sensors for space propulsion technology: Fabrication and preparation for testing
NASA Technical Reports Server (NTRS)
Kim, Walter S.; Hepp, Aloysius F.
1989-01-01
The goal of this work is to develop and test thin-film thermocouples for Space Shuttle Main Engine (SSME) components. Thin-film thermocouples have been developed for aircraft gas turbine engines and are in use for temperature measurement on turbine blades up to 1800 F. Established aircraft engine gas turbine technology is currently being adapted to turbine engine blade materials and the environment encountered in the SSME, especially severe thermal shock from cryogenic fuel to combustion temperatures. Initial results using coupons of MAR M-246 (+Hf) and PWA 1480 have been followed by fabrication of thin-film thermocouples on SSME turbine blades. Current efforts are focused on preparing for testing in the Turbine Blade Tester at the NASA Marshall Space Flight Center (MSFC). Future work will include testing of thin-film thermocouples on SSME blades of single crystal PWA 1480 at MSFC.
Career Preparation: A Longitudinal, Process-Oriented Examination
Stringer, Kate; Kerpelman, Jennifer; Skorikov, Vladimir
2011-01-01
Preparing for an adult career through careful planning, choosing a career, and gaining confidence to achieve career goals is a primary task during adolescence and early adulthood. The current study bridged identity process literature and career construction theory (Savickas, 2005) by examining the commitment component of career adaptability, career preparation (i.e., career planning, career decision-making, and career confidence), from an identity process perspective (Luyckx, Goossens, & Soenens, 2006). Research has suggested that career preparation dimensions are interrelated during adolescence and early adulthood; however, what remains to be known is how each dimension changes over time and the interrelationships among the dimensions during the transition from high school. Drawing parallels between career preparation and identity development dimensions, the current study addressed these questions by examining the patterns of change in each career preparation dimension and parallel process models that tested associations among the slopes and intercepts of the career preparation dimensions. Results showed that the career preparation dimensions were not developing similarly over time, although each dimension was associated cross-sectionally and longitudinally with the other dimensions. Results also suggested that career planning and decision-making precede career confidence. The results of the current study supported career construction theory and showed similarities between the processes of career preparation and identity development. PMID:21804641
Career Preparation: A Longitudinal, Process-Oriented Examination.
Stringer, Kate; Kerpelman, Jennifer; Skorikov, Vladimir
2011-08-01
Preparing for an adult career through careful planning, choosing a career, and gaining confidence to achieve career goals is a primary task during adolescence and early adulthood. The current study bridged identity process literature and career construction theory (Savickas, 2005) by examining the commitment component of career adaptability, career preparation (i.e., career planning, career decision-making, and career confidence), from an identity process perspective (Luyckx, Goossens, & Soenens, 2006). Research has suggested that career preparation dimensions are interrelated during adolescence and early adulthood; however, what remains to be known is how each dimension changes over time and the interrelationships among the dimensions during the transition from high school. Drawing parallels between career preparation and identity development dimensions, the current study addressed these questions by examining the patterns of change in each career preparation dimension and parallel process models that tested associations among the slopes and intercepts of the career preparation dimensions. Results showed that the career preparation dimensions were not developing similarly over time, although each dimension was associated cross-sectionally and longitudinally with the other dimensions. Results also suggested that career planning and decision-making precede career confidence. The results of the current study supported career construction theory and showed similarities between the processes of career preparation and identity development.
Preparation for Testing a Multi-Bay Box Subjected to Combined Loads
NASA Technical Reports Server (NTRS)
Rouse, Marshall; Jegley, Dawn
2015-01-01
The COmbined Loads Test System (COLTS) facility at NASA Langley Research Center provides a test capability to help develop validated structures technologies. The test machine was design to accommodate a range of fuselage structures and wing sections and subject them to both quasistatic and cyclic loading conditions. The COLTS facility is capable of testing fuselage barrels up to 4.6 m in diameter and 13.7 m long with combined mechanical, internal pressure, and thermal loads. The COLTS facility is currently being prepared to conduct a combined mechanical and pressure loading for a multi-bay pressure box to experimentally verify the structural performance of a composite structure which is 9.1 meters long and representative of a section of a hybrid wing body fuselage section in support of the Environmentally Responsible Aviation Project at NASA. This paper describes development of the multi-bay pressure box test using the COLTS facility. The multi-bay test article will be subjected to mechanical loads and internal pressure loads up to design ultimate load. Mechanical and pressure loads will be applied independently in some tests and simultaneously in others.
Bibliography of In-House and Contract Reports. Supplement 15.
1988-04-01
that approaches the aesthetic quality obtainable from experienced manual placement. )S 10 WNW oA ETL- 0428 AD-BI06 994L KNOWLEDGE-BASED VISION...Service Tests, and Production Model 1307 -TR 1953 Tests, Autofocusing Rectifier Development, Test, Preparation, Delivery, and ETL- 1307 1982 Installation of
Sawin, Kathleen J; Weiss, Marianne E; Johnson, Norah; Gralton, Karen; Malin, Shelly; Klingbeil, Carol; Lerret, Stacee M; Thompson, Jamie J; Zimmanck, Kim; Kaul, Molly; Schiffman, Rachel F
2017-03-01
Parents of hospitalized children, especially parents of children with complex and chronic health conditions, report not being adequately prepared for self-management of their child's care at home after discharge. No theory-based discharge intervention exists to guide pediatric nurses' preparation of parents for discharge. To develop a theory-based conversation guide to optimize nurses' preparation of parents for discharge and self-management of their child at home following hospitalization. Two frameworks and one method influenced the development of the intervention: the Individual and Family Self-Management Theory, Tanner's Model of Clinical Judgment, and the Teach-Back method. A team of nurse scientists, nursing leaders, nurse administrators, and clinical nurses developed and field tested the electronic version of a nine-domain conversation guide for use in acute care pediatric hospitals. The theory-based intervention operationalized self-management concepts, added components of nursing clinical judgment, and integrated the Teach-Back method. Development of a theory-based intervention, the translation of theoretical knowledge to clinical innovation, is an important step toward testing the effectiveness of the theory in guiding clinical practice. Clinical nurses will establish the practice relevance through future use and refinement of the intervention. © 2017 Sigma Theta Tau International.
Technology for advanced liquefaction processes: Coal/waste coprocessing studies
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cugini, A.V.; Rothenberger, K.S.; Ciocco, M.V.
1995-12-31
The efforts in this project are directed toward three areas: (1) novel catalyst (supported and unsupported) research and development, (2) study and optimization of major operating parameters (specifically pressure), and (3) coal/waste coprocessing. The novel catalyst research and development activity has involved testing supported catalysts, dispersed catalysts, and use of catalyst testing units to investigate the effects of operating parameters (the second area) with both supported and unsupported catalysts. Several supported catalysts were tested in a simulated first stage coal liquefaction application at 404{degrees}C during this performance period. A Ni-Mo hydrous titanate catalyst on an Amocat support prepared by Sandiamore » National laboratories was tested. Other baseline experiments using AO-60 and Amocat, both Ni-Mo/Al{sub 2}O{sub 3} supported catalysts, were also made. These experiments were short duration (approximately 12 days) and monitored the initial activity of the catalysts. The results of these tests indicate that the Sandia catalyst performed as well as the commercially prepared catalysts. Future tests are planned with other Sandia preparations. The dispersed catalysts tested include sulfated iron oxide, Bayferrox iron oxide (iron oxide from Miles, Inc.), and Bailey iron oxide (micronized iron oxide from Bailey, Inc.). The effects of space velocity, temperature, and solvent-to-coal ratio on coal liquefaction activity with the dispersed catalysts were investigated. A comparison of the coal liquefaction activity of these catalysts relative to iron catalysts tested earlier, including FeOOH-impregnated coal, was made. These studies are discussed.« less
Chmura, Helen E; Meddle, Simone L; Wingfield, John C; Hahn, Thomas P
2017-08-15
To time reproduction optimally, birds have evolved diverse mechanisms by which they respond to environmental changes that help them anticipate and prepare for the breeding season. While residents initiate reproductive preparation and breed in the same geographic location, migrant birds simultaneously prepare for breeding and migration far from their breeding grounds. As a result, it is hypothesized that migrant and resident birds use environmental cues differently to prepare to breed and that there is adaptive specialization in mechanisms regulating reproductive preparation. Specifically, residents are expected to rely more on non-photic cues (e.g. food, temperature, social cues) than migrants. We tested this general prediction using a social cue manipulation. First, we compared the effects of subspecies-appropriate recorded male song on reproductive development in migrants and residents on a naturally increasing photoperiod. Second, we tested the sensitivity of migrant-specific life history events (fattening and pre-alternate molt) to song treatment. After 82 days, residents had higher luteinizing hormone and greater ovarian development than migrants, but song treatment had no effect on these metrics in either subspecies. Song advanced pre-alternate molt but had no effect on fattening in migrants. While our study does not support specialization in social cue use in migrants and residents, it is consistent with findings in the literature of specialization in photoperiodic response. It also demonstrates for the first time that social cues can influence molt in a migrant species. Additional findings from a pilot study looking at responses to a live male suggest it is important to test other kinds of social cues. © 2017. Published by The Company of Biologists Ltd.
An Examination of the Perceived Importance of Technical Competence in Acquisition Project Management
1991-09-01
Develop (First Draft) Instructions Critique (Revision) Answerability Pilot Test (Second Draft) Analysis Response Mode Revision Useability Preparation...appropriate questionnaire items. Initially, the set of questions developed for the study reflected a few shortcomings. A pilot test of the first draft among...resulted. First, feedback from the pilot test indicated a need to reduce the completion time. Because the multiple choice format required several
Using the Microcomputer for Advertising Research Presentations.
ERIC Educational Resources Information Center
Larkin, Ernest F.
A midwestern university is testing a program that uses the Apple II computer to help students in an advertising research course develop their skills in preparing and presenting research reports using computer generated graphics for both oral and written presentations. One of the course requirements is the preparation of a final project, including…
Automotive Stirling engine development program
NASA Technical Reports Server (NTRS)
Ernst, W.; Richey, A.; Farrell, R.; Riecke, G.; Smith, G.; Howarth, R.; Cronin, M.; Simetkosky, M.; Meacher, J.
1986-01-01
This is the ninth Semiannual Technical Progress Report prepared under the Automotive Stirling Engine Development Program. It covers the twenty-eighth and twenty-ninth quarters of activity after award of the contract. Quarterly Technical Progress Reports related program activities from the first through the thirteenth quarters; thereafter, reporting was changed to a Semiannual format. This report summarizes the study of higher-power kinematic Stirling engines for transportation use, development testing of Mod I Stirling engines, and component development activities. Component development testing included successful conical fuel nozzle testing and functional checkout of Mod II controls and auxiliaries on Mod I engine test beds. Overall program philosophy is outlined and data and test results are presented.
Orion Neutral Buoyancy Lab (NBL) Activities
2016-09-20
Tim Goddard, NASA Open Water Recovery Operations director, briefs U.S. Navy divers, Air Force pararescuemen and Coast Guard rescue swimmers during training in the Neutral Buoyancy Laboratory at NASA’s Johnson Space Center in Houston. The group is preparing to practice Orion underway recovery techniques using a test version of the Orion spacecraft. Training will help the team prepare for Underway Recovery Test 5 for Exploration Mission 1 aboard the USS San Diego in the Pacific Ocean off the coast of California in October. The Ground Systems Development and Operations Program, along with the U.S. Navy and Lockheed Martin, are preparing the recovery team, hardware and operations to support EM-1 recovery.
Orion Neutral Buoyancy Lab (NBL) Activities
2016-09-20
Tim Goddard, far right, NASA Open Water Recovery Operations director, briefs U.S. Navy divers, Air Force pararescuemen and Coast Guard rescue swimmers during training in the Neutral Buoyancy Laboratory at NASA’s Johnson Space Center in Houston. The group is preparing to practice Orion underway recovery techniques using a test version of the Orion spacecraft. Training will help the team prepare for Underway Recovery Test 5 for Exploration Mission 1 aboard the USS San Diego in the Pacific Ocean off the coast of California in October. The Ground Systems Development and Operations Program, along with the U.S. Navy and Lockheed Martin, are preparing the recovery team, hardware and operations to support EM-1 recovery.
Orion Neutral Buoyancy Lab (NBL) Activities
2016-09-20
NASA astronaut Dan Burbank speaks to a group of U.S. Navy divers at the Neutral Buoyancy Laboratory (NBL) at the agency’s Johnson Space Center in Houston. Navy divers, Air Force pararescuemen and Coast Guard rescue swimmers are preparing to practice Orion underway recovery techniques with a test version of the Orion spacecraft. Training will help the team prepare for Underway Recovery Test 5 for Exploration Mission 1 aboard the USS San Diego in the Pacific Ocean off the coast of California in October. The Ground Systems Development and Operations Program, along with the U.S. Navy and Lockheed Martin, are preparing the recovery team, hardware and operations to support EM-1 recovery.
Handley, J; Burrows, D
1994-11-01
The case is reported of a 28-year-old man who developed allergic contact dermatitis from 2 synthetic fragrance ingredients, Lyral (3- and 4-(4-hydroxy-4-methylpentyl)-3-cyclohexene-1-aldehyde) and acetyl cedrene, in separate underarm deodorant preparations. The implications of the patient's negative patch test reactions to the European standard series (Trolab) and cosmetics and fragrance series (both Chemotechnique Diagnostics) are discussed. The importance is stressed of patch testing with the patient's own preparations when cosmetic dermatitis is suspected, and of identifying and reporting offending fragrance ingredients, with a view possibly to updating the European standard series and commercially available cosmetics and fragrance series.
Plasma Processing of Model Residential Solid Waste
NASA Astrophysics Data System (ADS)
Messerle, V. E.; Mossé, A. L.; Nikonchuk, A. N.; Ustimenko, A. B.; Baimuldin, R. V.
2017-09-01
The authors have tested the technology of processing of model residential solid waste. They have developed and created a pilot plasma unit based on a plasma chamber incinerator. The waste processing technology has been tested and prepared for commercialization.
Test Specifications and Blueprints: Reality and Expectations
ERIC Educational Resources Information Center
AlFallay, Ibrahim S.
2018-01-01
This study investigates to what extend do teachers of English as a school subject (ESS) in Saudi schools follow recommendations and guidelines suggested by language testing specialists in developing tables of specifications and preparing blueprints to their formative and summative language tests. To answer the study questions, a thirteen-statement…
"Tackling Test Anxiety": A Group for College Students
ERIC Educational Resources Information Center
Damer, Diana E.; Melendres, Lauren T.
2011-01-01
Test anxiety is ubiquitous on college campuses and negatively impacts academic progress as well as overall mental and physical health. Some students develop test anxiety due to poor study skills, while others experience debilitating anxiety despite adequate preparation. In this article, a session-by-session description of a 4-week group…
Study Guide for TCT in Agriculture.
ERIC Educational Resources Information Center
Sailors, Robert A.
This study guide was specifically designed for individuals preparing to take the Georgia Teacher Certification Test (TCT) in agriculture. The agriculture test was developed by the National Evaluation Systems, Inc. and educators in Georgia. The test covers 13 subareas: (1) plant science; (2) crop management; (3) animal science; (4) livestock and…
THhe MLA Foreign Language Proficiency Tests for Teachers and Advanced Students.
ERIC Educational Resources Information Center
del Olmo, Guillermo
1967-01-01
The development, design, and purposes of these advanced proficiency tests are discussed, along with brief descriptions of their seven component parts--listening comprehension, speaking, reading, writing, applied linguistics, civilization and culture, and professional preparation. Some of the research inspired by the tests is identified. (AF)
Proposed activities to prepare for testing advanced/stealth weapons systems
NASA Astrophysics Data System (ADS)
Bishop, Harold T.
1989-08-01
The B-2 brings new challenges for Electromagnetic Pulse (EMP) Testing. This paper discusses the unique characteristics of the B-2 and develops a time line of activities that need to be completed by the AF Weapons Laboratory before EMP testing of the B-2 begins.
Smart command recognizer (SCR) - For development, test, and implementation of speech commands
NASA Technical Reports Server (NTRS)
Simpson, Carol A.; Bunnell, John W.; Krones, Robert R.
1988-01-01
The SCR, a rapid prototyping system for the development, testing, and implementation of speech commands in a flight simulator or test aircraft, is described. A single unit performs all functions needed during these three phases of system development, while the use of common software and speech command data structure files greatly reduces the preparation time for successive development phases. As a smart peripheral to a simulation or flight host computer, the SCR interprets the pilot's spoken input and passes command codes to the simulation or flight computer.
ESO adaptive optics facility progress report
NASA Astrophysics Data System (ADS)
Arsenault, Robin; Madec, Pierre-Yves; Paufique, Jerome; La Penna, Paolo; Stroebele, Stefan; Vernet, Elise; Pirard, Jean-Francois; Hackenberg, Wolfgang; Kuntschner, Harald; Jochum, Lieselotte; Kolb, Johann; Muller, Nicolas; Le Louarn, Miska; Amico, Paola; Hubin, Norbert; Lizon, Jean-Louis; Ridings, Rob; Abad, Jose A.; Fischer, Gert; Heinz, Volker; Kiekebusch, Mario; Argomedo, Javier; Conzelmann, Ralf; Tordo, Sebastien; Donaldson, Robert; Soenke, Christian; Duhoux, Philippe; Fedrigo, Enrico; Delabre, Bernard; Jost, Andreas; Duchateau, Michel; Downing, Mark; Moreno, Javier R.; Dorn, Reinhold; Manescau, Antonio; Bonaccini Calia, Domenico; Quattri, Marco; Dupuy, Christophe; Guidolin, Ivan M.; Comin, Mauro; Guzman, Ronald; Buzzoni, Bernard; Quentin, Jutta; Lewis, Steffan; Jolley, Paul; Kraus, Maximilian; Pfrommer, Thomas; Biasi, Roberto; Gallieni, Daniele; Bechet, Clementine; Stuik, Remko
2012-07-01
The ESO Adaptive Optics Facility (AOF) consists in an evolution of one of the ESO VLT unit telescopes to a laser driven adaptive telescope with a deformable mirror in its optical train. The project has completed the procurement phase and several large structures have been delivered to Garching (Germany) and are being integrated (the AO modules GRAAL and GALACSI and the ASSIST test bench). The 4LGSF Laser (TOPTICA) has undergone final design review and a pre-production unit has been built and successfully tested. The Deformable Secondary Mirror is fully integrated and system tests have started with the first science grade thin shell mirror delivered by SAGEM. The integrated modules will be tested in stand-alone mode in 2012 and upon delivery of the DSM in late 2012, the system test phase will start. A commissioning strategy has been developed and will be updated before delivery to Paranal. A substantial effort has been spent in 2011-2012 to prepare the unit telescope to receive the AOF by preparing the mechanical interfaces and upgrading the cooling and electrical network. This preparation will also simplify the final installation of the facility on the telescope. A lot of attention is given to the system calibration, how to record and correct any misalignment and control the whole facility. A plan is being developed to efficiently operate the AOF after commissioning. This includes monitoring a relevant set of atmospheric parameters for scheduling and a Laser Traffic control system to assist the operator during the night and help/support the observing block preparation.
NASA Astrophysics Data System (ADS)
Pichon, T.; Barreteau, R.; Soyris, P.; Foucault, A.; Parenteau, J. M.; Prel, Y.; Guedron, S.
2009-07-01
Experimental re-entry demonstrators are currently being developed in Europe, with the objective of increasing the technology readiness level (TRL) of technologies applicable to future reusable launch vehicles. Among these are the Pre-X programme, currently funded by CNES, the French Space Agency, and which is about to enter into development phase B, and the IXV, within the future launcher preparatory programme (FLPP) funded by ESA. One of the major technologies necessary for such vehicles is the thermal protection system (TPS), and in particular the ceramic matrix composites (CMC) based windward TPS. In support of this goal, technology maturation activities named "generic shingle" were initiated beginning of 2003 by SPS, under a CNES contract, with the objective of performing a test campaign of a complete shingle of generic design, in preparation of the development of a re-entry experimental vehicle decided in Europe. The activities performed to date include: the design, manufacturing of two C/SiC panels, finite element model (FEM) calculation of the design, testing of technological samples extracted from a dedicated panel, mechanical pressure testing of a panel, and a complete study of the attachment system. Additional testing is currently under preparation on the panel equipped with its insulation, seal, attachment device, and representative portion of cold structure, to further assess its behaviour in environments relevant to its application The paper will present the activities that will have been performed in 2006 on the prediction and preparation of these modal characterization, dynamic, acoustic as well as thermal and thermo-mechanical tests. Results of these tests will be presented and the lessons learned will be discussed.
Kain, Zeev N.; Fortier, Michelle A.; Chorney, Jill MacLaren; Mayes, Linda
2014-01-01
Background Due to cost-containment efforts, preparation programs for outpatient surgery are currently not available to the majority of children and parents. The recent dramatic growth in the Internet presents a unique opportunity to transform how children and their parents are prepared for surgery. In this article we describe the development of a Web-based tailored preparation program for children and parents undergoing surgery (WebTIPS). Development of Program A multidisciplinary taskforce agreed that a Web-based tailored intervention comprised of intake, matrix and output modules was the preferred approach. Next, the content of the various intake variables, the matrix logic and the output content was developed. The output product has a parent component and a child component and is described in http://surgerywebtips.com/about.php. The child component makes use of preparation strategies such as information provision, modeling, play and coping skills training. The parent component of WebTIPS includes strategies such as information provision, coping skills training, relaxation and distraction techniques. A reputable animation and Web-design company developed a secured Web-based product based on the above description. Conclusions In this article we describe the development of a Web-based tailored preoperative preparation program that can be accessed by children and parents multiple times before and after surgery. A follow-up article in this issue of Anesthesia & Analgesia describes formative evaluation and preliminary efficacy testing of this Web-based tailored preoperative preparation program. PMID:25790212
Flexing Your Test Muscles: A Guide to Developing Test-Taking Skills.
ERIC Educational Resources Information Center
Florida State Dept. of Education, Tallahassee. Student Assessment Section.
This booklet is designed for elementary and middle school teachers to use in teaching students how to improve their test-taking skills. The authors draw the analogy between an athlete preparing for the big race and a young student getting ready for an important test. The central character is an underdeveloped test-taking tiger who, after going…
Ceramic applications in turbine engines
NASA Technical Reports Server (NTRS)
Byrd, J. A.; Janovicz, M. A.; Thrasher, S. R.
1981-01-01
Development testing activities on the 1900 F-configuration ceramic parts were completed, 2070 F-configuration ceramic component rig and engine testing was initiated, and the conceptual design for the 2265 F-configuration engine was identified. Fabrication of the 2070 F-configuration ceramic parts continued, along with burner rig development testing of the 2070 F-configuration metal combustor in preparation for 1132 C (2070 F) qualification test conditions. Shakedown testing of the hot engine simulator (HES) rig was also completed in preparation for testing of a spin rig-qualified ceramic-bladed rotor assembly at 1132 C (2070 F) test conditions. Concurrently, ceramics from new sources and alternate materials continued to be evaluated, and fabrication of 2070 F-configuration ceramic component from these new sources continued. Cold spin testing of the critical 2070 F-configuration blade continued in the spin test rig to qualify a set of ceramic blades at 117% engine speed for the gasifier turbine rotor. Rig testing of the ceramic-bladed gasifier turbine rotor assembly at 108% engine speed was also performed, which resulted in the failure of one blade. The new three-piece hot seal with the nickel oxide/calcium fluoride wearface composition was qualified in the regenerator rig and introduced to engine operation wiwth marginal success.
NASA Technical Reports Server (NTRS)
Pannell, C. E.; Magner, J. E.
1973-01-01
A polymer has been developed that has excellent potential for use as windows in spacecraft as well as conventional aircraft. This polymer, phenolphthalein polycarbonate, has outstanding thermal properties, e.g., in place of melting or burning, it produces an insulating charred foam that closes off transmission of radiant heat through the window. This fact, coupled with an oxygen index of 0.43 and a 177 C tensile strength of 58 mega Newtons/sq m, makes this polymer a prime candidate for further development. Pilot plant preparation in a 20 gallon Pfaudler kettle was accomplished and large test specimens were prepared for evaluations.
A-2 Test Stand modification work
2010-10-27
John C. Stennis Space Center employees install a new master interface tool on the A-2 Test Stand on Oct. 27, 2010. Until July 2009, the stand had been used for testing space shuttle main engines. With that test series complete, employees are preparing the stand for testing the next-generation J-2X rocket engine being developed. Testing of the new engine is scheduled to begin in 2011.
Transparent superstrate terrestrial solar cell module
NASA Technical Reports Server (NTRS)
1977-01-01
The design, development, fabrication, and testing of the transparent solar cell module were examined. Cell performance and material process characteristics were determined by extensive tests and design modifications were made prior to preproduction fabrication. These tests included three cell submodules and two full size engineering modules. Along with hardware and test activity, engineering documentation was prepared and submitted.
Achievement Test Preparation: A Year-Long Goal, Not a Last-Minute Thought.
ERIC Educational Resources Information Center
Matter, M. Kevin; Ligon, Glynn
Yearly administrations of a standardized achievement test are a part of the educational process in many school districts in the United States. The Systemwide Testing Program in the Austin Independent School District Office of Research and Evaluation has gradually developed a process and support materials whereby the test administrations are a tool…
Processing and Preparation of Advanced Stirling Convertors for Extended Operation
NASA Technical Reports Server (NTRS)
Oriti, Salvatore M.; Cornell, Paggy A.
2008-01-01
The U.S. Department of Energy (DOE), Lockheed Martin Space Company (LMSC), Sunpower Inc., and NASA Glenn Research Center (GRC) have been developing an Advanced Stirling Radioisotope Generator (ASRG) for use as a power system on space science missions. This generator will make use of the free-piston Stirling convertors to achieve higher conversion efficiency than currently available alternatives. NASA GRC is supporting the development of the ASRG by providing extended operation of several Sunpower Inc. Advanced Stirling Convertors (ASCs). In the past year and a half, eight ASCs have operated in continuous, unattended mode in both air and thermal vacuum environments. Hardware, software, and procedures were developed to prepare each convertor for extended operation with intended durations on the order of tens of thousands of hours. Steps taken to prepare a convertor for long-term operation included geometry measurements, thermocouple instrumentation, evaluation of working fluid purity, evacuation with bakeout, and high purity charge. Actions were also taken to ensure the reliability of support systems, such as data acquisition and automated shutdown checkouts. Once a convertor completed these steps, it underwent short-term testing to gather baseline performance data before initiating extended operation. These tests included insulation thermal loss characterization, low-temperature checkout, and full-temperature and power demonstration. This paper discusses the facilities developed to support continuous, unattended operation, and the processing results of the eight ASCs currently on test.
NASA Technical Reports Server (NTRS)
Oriti, Salvatore M.; Cornell, Peggy A.
2008-01-01
The U.S. Department of Energy (DOE), Lockheed Martin Space Company (LMSC), Sunpower Inc., and NASA Glenn Research Center (GRC) have been developing an Advanced Stirling Radioisotope Generator (ASRG) for use as a power system on space science missions. This generator will make use of the free-piston Stirling convertors to achieve higher conversion efficiency than currently available alternatives. NASA GRC is supporting the development of the ASRG by providing extended operation of several Sunpower Inc. Advanced Stirling Convertors (ASCs). In the past year and a half, eight ASCs have operated in continuous, unattended mode in both air and thermal vacuum environments. Hardware, software, and procedures were developed to prepare each convertor for extended operation with intended durations on the order of tens of thousands of hours. Steps taken to prepare a convertor for long-term operation included geometry measurements, thermocouple instrumentation, evaluation of working fluid purity, evacuation with bakeout, and high purity charge. Actions were also taken to ensure the reliability of support systems, such as data acquisition and automated shutdown checkouts. Once a convertor completed these steps, it underwent short-term testing to gather baseline performance data before initiating extended operation. These tests included insulation thermal loss characterization, low-temperature checkout, and full-temperature and power demonstration. This paper discusses the facilities developed to support continuous, unattended operation, and the processing results of the eight ASCs currently on test.
Development of a qualification standard for adhesives used in hybrid microcircuits
NASA Technical Reports Server (NTRS)
Licari, J. J.; Weigand, B. L.; Soykin, C. A.
1981-01-01
Improved qualification standards and test procedures for adhesives used in microelectronic packaging are developed. The test methods in specification for the Selection and Use of Organic Adhesives in Hybrid Microcircuits are reevaluated versus industry and government requirements. Four electrically insulative and four electrically conductive adhesives used in the assembly of hybrid microcircuits are selected to evaluate the proposed revised test methods. An estimate of the cost to perform qualification testing of an adhesive to the requirements of the revised specification is also prepared.
Shuttle environmental and thermal control/life support system computer program, supplement 1
NASA Technical Reports Server (NTRS)
Ayotte, W. J.
1975-01-01
The computer programs developed to simulate the RSECS (Representative Shuttle Environmental Control System) were described. These programs were prepared to provide pretest predictions, post-test analysis and real time problem analysis for RSECS test planning and evaluation.
ANALYSIS OF ALDEHYDES AND KETONES IN THE GAS PHASE
The development and testing of a 2,4-dinitrophenylhydrazine-acetonitrile (DNPH-ACN) method for the analysis of aldehydes and ketones in ambient air are described. A discussion of interferences, preparation of calibration standards, analytical testing, fluorescence methods and car...
SRB Processing Facilities Media Event
2016-03-01
Members of the news media view the high bay inside the Rotation, Processing and Surge Facility (RPSF) at NASA’s Kennedy Space Center in Florida. Inside the RPSF, engineers and technicians with Jacobs Engineering on the Test and Operations Support Contract, explain the various test stands. In the far corner is one of two pathfinders, or test versions, of solid rocket booster segments for NASA’s Space Launch System rocket. The Ground Systems Development and Operations Program and Jacobs are preparing the booster segments, which are inert, for a series of lifts, moves and stacking operations to prepare for Exploration Mission-1, deep-space missions and the journey to Mars.
ERIC Educational Resources Information Center
Achieve, Inc., 2015
2015-01-01
Today's economy demands that all young people develop high-level literacy, quantitative reasoning, problem solving, communication, and collaboration skills, all grounded in a rigorous and content-rich K-12 curriculum. Acquiring these skills ensures that high school graduates are academically prepared to pursue the future of their choosing.…
ERIC Educational Resources Information Center
Greenseid, Lija O.; Lawrenz, Frances
2011-01-01
A team at the University of Minnesota conducted the Collaboratives for Excellence in Teacher Preparation (CETP) core evaluation between 1999 and 2004. The purpose of the CETP core evaluation was to achieve consensus among CETP project leaders and project evaluators on evaluation questions; to develop, pilot, and field test evaluation instruments…
ERIC Educational Resources Information Center
Brown, Irving A.; Davis, Trina J.; Kulm, Gerald
2011-01-01
This article presents our plans and initial work to explore how mathematics teacher education programs can prepare teachers for diverse middle grades classrooms. It describes the start-up of a five-year National Science Foundation project to design, develop, and test technology-enriched teacher preparation strategies to address equity in algebra…
ERIC Educational Resources Information Center
National Academy of Sciences - National Research Council, Washington, DC. Inst. of Lab. Animal Resources.
This volume contains the prepared papers and discussions of a National Academy of Sciences - National Research Council Symposium on the Future of Animals, Cells, Models, and Systems in Research, Development, Education, and Testing. The purpose of the symposium was to examine the past, present, and future contributions of animals to human health…
Perseus B Taxi Tests in Preparation for a New Series of Flight Tests
1998-04-27
The Perseus B remotely piloted aircraft taxis on the runway at Edwards Air Force Base, California, before a series of development flights at NASA's Dryden flight Research Center. The Perseus B is the latest of three versions of the Perseus design developed by Aurora Flight Sciences under NASA's Environmental Research Aircraft and Sensor Technology (ERAST) program.
Perseus B Taxi Tests in Preparation for a New Series of Flight Tests
1998-04-27
The Perseus B remotely piloted aircraft on the runway at Edwards Air Force Base, California at the conclusion of a development flight at NASA's Dryden flight Research Center. The Perseus B is the latest of three versions of the Perseus design developed by Aurora Flight Sciences under NASA's Environmental Research Aircraft and Sensor Technology (ERAST) program.
Secondary Waste Simulant Development for Cast Stone Formulation Testing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Russell, Renee L.; Westsik, Joseph H.; Rinehart, Donald E.
Washington River Protection Solutions, LLC (WRPS) funded Pacific Northwest National Laboratory (PNNL) to conduct a waste form testing program to implement aspects of the Secondary Liquid Waste Treatment Cast Stone Technology Development Plan (Ashley 2012) and the Hanford Site Secondary Waste Roadmap (PNNL 2009) related to the development and qualification of Cast Stone as a potential waste form for the solidification of aqueous wastes from the Hanford Site after the aqueous wastes are treated at the Effluent Treatment Facility (ETF). The current baseline is that the resultant Cast Stone (or grout) solid waste forms would be disposed at the Integratedmore » Disposal Facility (IDF). Data and results of this testing program will be used in the upcoming performance assessment of the IDF and in the design and operation of a solidification treatment unit planned to be added to the ETF. The purpose of the work described in this report is to 1) develop simulants for the waste streams that are currently being fed and future WTP secondary waste streams also to be fed into the ETF and 2) prepare simulants to use for preparation of grout or Cast Stone solid waste forms for testing.« less
A Ricin Forensic Profiling Approach Based on a Complex Set of Biomarkers
Fredriksson, Sten-Ake; Wunschel, David S.; Lindstrom, Susanne Wiklund; ...
2018-03-28
A forensic method for the retrospective determination of preparation methods used for illicit ricin toxin production was developed. The method was based on a complex set of biomarkers, including carbohydrates, fatty acids, seed storage proteins, in combination with data on ricin and Ricinus communis agglutinin. The analyses were performed on samples prepared from four castor bean plant (R. communis) cultivars by four different sample preparation methods (PM1 – PM4) ranging from simple disintegration of the castor beans to multi-step preparation methods including different protein precipitation methods. Comprehensive analytical data was collected by use of a range of analytical methods andmore » robust orthogonal partial least squares-discriminant analysis- models (OPLS-DA) were constructed based on the calibration set. By the use of a decision tree and two OPLS-DA models, the sample preparation methods of test set samples were determined. The model statistics of the two models were good and a 100% rate of correct predictions of the test set was achieved.« less
A Ricin Forensic Profiling Approach Based on a Complex Set of Biomarkers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fredriksson, Sten-Ake; Wunschel, David S.; Lindstrom, Susanne Wiklund
A forensic method for the retrospective determination of preparation methods used for illicit ricin toxin production was developed. The method was based on a complex set of biomarkers, including carbohydrates, fatty acids, seed storage proteins, in combination with data on ricin and Ricinus communis agglutinin. The analyses were performed on samples prepared from four castor bean plant (R. communis) cultivars by four different sample preparation methods (PM1 – PM4) ranging from simple disintegration of the castor beans to multi-step preparation methods including different protein precipitation methods. Comprehensive analytical data was collected by use of a range of analytical methods andmore » robust orthogonal partial least squares-discriminant analysis- models (OPLS-DA) were constructed based on the calibration set. By the use of a decision tree and two OPLS-DA models, the sample preparation methods of test set samples were determined. The model statistics of the two models were good and a 100% rate of correct predictions of the test set was achieved.« less
Further Research on an Undergraduate Measure of Professional Development Engagement
ERIC Educational Resources Information Center
Blau, Gary; Pred, Robert; Andersson, Lynne; Lopez, Andrea B.
2015-01-01
Professional Development Engagement (PDE) refers to the level of undergraduate engagement in professional development. Professional Development (PD) involves activities designed to help students prepare for a successful college-to-work transition. This study tested a new 12-item measure of PDE for a complete-data sample of 246 undergraduate…
ERIC Educational Resources Information Center
Turner, Matthew J.; Rios, Jose M.
2008-01-01
Recent education reform efforts are at the forefront of educators' minds across the nation, science teachers notwithstanding. At least 48 states have developed a mandated standardized test, the majority of which also publish an individual school proficiency report. Washington State's new standardized science test is an example of such reforms…
Classification of Oral Proficiency Tests.
ERIC Educational Resources Information Center
Madsen, Harold S.; Jones, Randall L.
A recently conducted survey has disclosed that during the past few years there has been a significant increase in the development of speaking tests. Examination of 100 speaking tests revealed many varieties and many considerations in preparing and using them. Among these are the purpose for its use, the background of the examinee, the criteria…
Fighting the flu: developing sustained community resilience and preparedness.
Paton, Douglas; Parkes, Bruce; Daly, Michele; Smith, Leigh
2008-10-01
A pandemic will impose considerable demands on communities over a period of several weeks; thus, people must develop means to facilitate their resilience in such an event. This article describes the development and testing of a model to inform public education strategies to facilitate the sustained adoption of the preparedness and protective measures that underpin community resilience. The model is derived from the premise that decisions to act reflect how people interpret information to make it meaningful to them. The model describes how this outcome reflects the interaction among personal beliefs about preparing, community characteristics influencing how risk beliefs and risk management strategies are developed, and the relationship between the community and health information sources. It highlights a need to distinguish those who decide not to prepare from those who accept a need to prepare but need guidance. Implications for developing pandemic public education and risk communication programs are discussed.
Advanced on-site power plant development technology program
NASA Technical Reports Server (NTRS)
Kemp, F. S.
1985-01-01
A 30-cell stack was tested for 7200 hours. At 6000 hours the stack was successfully refilled with acid with no loss of performance. A second stack containing the advanced Configuration B cell package was fabricated and assembled for testing in 1985. A 200-kW brassboard inverter was successfully evaluated, verifying the design of the two-bridge ASCR circuit design. A fuel processing catalyst train was tested for 2000 hours verifying the catalyst for use in a 200-kW development reformer. The development reformer was fabricated for evaluation in 1985. The initial test plan was prepared for a 200-kW verification test article.
Pegasus Rocket Booster Being Prepared for X-43A/Hyper-X Flight Test
1999-08-25
A close-up view of the front end of a Pegasus rocket booster being prepared by technicians at the Dryden Flight Research Center for flight tests with the X-43A "Hypersonic Experimental Vehicle," or "Hyper-X." The X-43A, which will be attached to the Pegasus booster and drop launched from NASA's B-52 mothership, was developed to research dual-mode ramjet/scramjet propulsion system at speeds from Mach 7 up to Mach 10 (7 to 10 times the speed of sound, which varies with temperature and altitude).
SRB Processing Facilities Media Event
2016-03-01
At the Rotation, Processing and Surge Facility (RPSF) at NASA’s Kennedy Space Center in Florida, members of the news media photograph the process as cranes are used to lift one of two pathfinders, or test versions, of solid rocket booster segments for NASA’s Space Launch System rocket. The Ground Systems Development and Operations Program and Jacobs Engineering, on the Test and Operations Support Contract, are preparing the booster segments, which are inert, for a series of lifts, moves and stacking operations to prepare for Exploration Mission-1, deep-space missions and the journey to Mars.
SRB Processing Facilities Media Event
2016-03-01
At the Rotation, Processing and Surge Facility (RPSF) at NASA’s Kennedy Space Center in Florida, members of the news media watch as cranes are used to lift one of two pathfinders, or test versions, of solid rocket booster segments for NASA’s Space Launch System rocket. The Ground Systems Development and Operations Program and Jacobs Engineering, on the Test and Operations Support Contract, are preparing the booster segments, which are inert, for a series of lifts, moves and stacking operations to prepare for Exploration Mission-1, deep-space missions and the journey to Mars.
1989-02-28
AD-A259 245 RESEARCH TRIANGLE INSTITUTE I SOFTWARE SYSTEM USER’S MANUAL, REFERENCE MANUAL, AND INSTALLATION GUIDE FOR THE TEST ENGINEER’S ASSISTANT...SYSTEM U. yD"VxC - February 28, 1989 Iŕ 5 G3 ’Contract No. DAAL01-86-C-0039 W Prepared for: Department of the Army Electronics Research and...Development Command Fort Monmouth, New Jersey 07703 I Prepared by: Center for Digital Systems ResearchI Research Triangle Institute Research Triangle Park, NC
[Preparation of bioindicators for controlling the efficacy of sterilization processes].
Kalinina, N M; Tikhonova, A S; Motina, G L; Chaĭkovskaia, S M; Semenov, S M
1983-08-01
A test microbe for the control of the efficacy of vacuum steam sterilization was selected. Conditions for the spore cultivation were developed. The optimal bioindicator composition, test microbe loading, nutrient medium, pH indicator, carbohydrates and a carrier were defined.
Content Standards: High Stakes Anti-Differentiation
ERIC Educational Resources Information Center
Schroeder-Davis, Stephen
2011-01-01
Currently, American schooling, driven by No Child Left Behind (NCLB) and standardized tests, emphasizes development of intelligence. Because of this, teachers must heavily emphasize acquisition of foundational information (facts) in lectures, assessments, and of course, time-consuming test preparation, at the expense of intellect, that…
Baron, Alice; Verdié, Pascal; Martinez, Jean; Lamaty, Frédéric
2011-02-04
A new linker cis-5-aminopent-3-enoic acid (cis-Apa) was prepared for the synthesis of cyclic pseudopeptides by cyclization-cleavage by using ring-closing methatesis (RCM). We developed a new synthetic pathway for the preparation of the cis-Apa linker that was tested in the cyclization-cleavage process of different RGD peptide sequences. Different macrocyclic peptidomimetics were prepared by using this integrated microwave-assisted method, showing that the readily available cis-Apa amino acid is well adapted as a linker in the cyclization-cleavage process.
Tseng, Shao-Chin; Yu, Chen-Chieh; Wan, Dehui; Chen, Hsuen-Li; Wang, Lon Alex; Wu, Ming-Chung; Su, Wei-Fang; Han, Hsieh-Cheng; Chen, Li-Chyong
2012-06-05
Convenient, rapid, and accurate detection of chemical and biomolecules would be a great benefit to medical, pharmaceutical, and environmental sciences. Many chemical and biosensors based on metal nanoparticles (NPs) have been developed. However, as a result of the inconvenience and complexity of most of the current preparation techniques, surface plasmon-based test papers are not as common as, for example, litmus paper, which finds daily use. In this paper, we propose a convenient and practical technique, based on the photothermal effect, to fabricate the plasmonic test paper. This technique is superior to other reported methods for its rapid fabrication time (a few seconds), large-area throughput, selectivity in the positioning of the NPs, and the capability of preparing NP arrays in high density on various paper substrates. In addition to their low cost, portability, flexibility, and biodegradability, plasmonic test paper can be burned after detecting contagious biomolecules, making them safe and eco-friendly.
Preschooler test or procedure preparation
Preparing preschoolers for test/procedure; Test/procedure preparation - preschooler ... Preparing children for medical tests can reduce their anxiety. It can also make them less likely to cry and resist the procedure. Research shows that ...
Development and Test Evaluations for Ni-DOBDC Metal Organic Framework (MOF) Engineered Forms
DOE Office of Scientific and Technical Information (OSTI.GOV)
Troy G. Garn; Mitchell Greenhalgh
2013-07-01
A joint effort to prepare engineered forms of a Ni-DOBDC metal organic framework (MOF) was completed with contributions from PNNL, SNL and the INL. Two independent methods were used at INL and SNL to prepare engineered form (EF) sorbents from Ni-DOBDC MOF powder developed and prepared at PNNL. Xe and Kr capacity test evaluations were performed at ambient temperature with the cryostat experimental setup at INL. The initial INL EF MOF test results indicated a Xe capacity of 1.6 mmol/kg sorbent and no Kr capacity. A large loss of surface area also occurred during minimal testing rendering the INL EFmore » MOF unusable. Four capacity tests were completed using the SNL EF MOF at ambient temperature and resulted in Xe capacities of 1.4, 4.2, 5.0 and 3.8 mmol/kg sorbent with no Kr capacity observed in any ambient temperature tests. Two additional capacity tests were performed at 240 K to further evaluate SNL EF MOF performance. Xe capacities of 50.7 and 49.3 mmol/kg of sorbent and Kr capacities of 0.77 and 0.69 mmol/kg of sorbent were obtained, respectively. Following the adsorption evaluations, the SNL EF MOF material had lost about 40 % of the initial mass and 40 % of the initial surface area. In general, the Xe capacity results at ambient temperature for the INL and SNL EF Ni-DOBDC MOF’s were lower than 9.8 mmol Xe/kg sorbent test results reported by INL in FY-12 using PNNL’s inital EF supplied material.« less
ERIC Educational Resources Information Center
Asian Cultural Centre for UNESCO, Tokyo (Japan).
The proceedings of the sixth regional workshop consist of a description of the project and the workshop; a description of the field survey, preparation, and field testing of materials by the group; five papers presented at the workshop; and notes on planned follow-up activities in the participating countries. The workshop culminated a project on…
US Army Proposed Automatic Test Equipment Software Development and Support Facility.
1982-10-29
programs would be prepared as weapon and prime system operating software. The ATE Software Development and Support Facility will help prevent the TPS...ONE AS A STANDARD **Partially being Developed (2) UNDER DEVELOP- by Navy CSS Prgram MENT (3) NEEDS TAILOR- (5) NEEDS ING FOR ARMY DEVELOPMENT A- 2
Preparation for Analytical Measurements on Mars
2015-03-31
A Sample Analysis at Mars (SAM) team member at NASA's Goddard Space Flight Center, Greenbelt, Maryland, prepares the SAM testbed for an experiment. This test copy of the SAM suite of instruments is inside a chamber that, when closed, can model the pressure and temperature environment that SAM sees inside NASA's Curiosity rover on Mars. Many weeks of testing are often needed to develop and refine sequences of operations that SAM uses for making specific measurements on Mars. This was the case with preparation to pull a volume of gas from the atmosphere and extract the heavy noble gas xenon. SAM's measurements of different types of xenon in the Martian atmosphere provide clues about the planet's history. http://photojournal.jpl.nasa.gov/catalog/PIA19149
Kain, Zeev N; Fortier, Michelle A; Chorney, Jill MacLaren; Mayes, Linda
2015-04-01
As a result of cost-containment efforts, preparation programs for outpatient surgery are currently not available to the majority of children and parents. The recent dramatic growth in the Internet presents a unique opportunity to transform how children and their parents are prepared for surgery. In this article, we describe the development of a Web-based Tailored Intervention for Preparation of parents and children undergoing Surgery (WebTIPS). A multidisciplinary taskforce agreed that a Web-based tailored intervention consisting of intake, matrix, and output modules was the preferred approach. Next, the content of the various intake variables, the matrix logic, and the output content was developed. The output product has a parent component and a child component and is described in http://surgerywebtips.com/about.php. The child component makes use of preparation strategies such as information provision, modeling, play, and coping skills training. The parent component of WebTIPS includes strategies such as information provision, coping skills training, and relaxation and distraction techniques. A reputable animation and Web design company developed a secured Web-based product based on the above description. In this article, we describe the development of a Web-based tailored preoperative preparation program that can be accessed by children and parents multiple times before and after surgery. A follow-up article in this issue of Anesthesia & Analgesia describes formative evaluation and preliminary efficacy testing of this Web-based tailored preoperative preparation program.
Developing Achievement Test: A Research for Assessment of 5th Grade Biology Subject
ERIC Educational Resources Information Center
Sener, Nilay; Tas, Erol
2017-01-01
The purpose of this study is to prepare a multiple-choice achievement test with high reliability and validity for the "Let's Solve the Puzzle of Our Body" unit. For this purpose, a multiple choice achievement test consisting of 46 items was applied to 178 fifth grade students in total. As a result of the test and material analysis…
Preparation and Integration of ALHAT Precision Landing Technology for Morpheus Flight Testing
NASA Technical Reports Server (NTRS)
Carson, John M., III; Robertson, Edward A.; Pierrottet, Diego F.; Roback, Vincent E.; Trawny, Nikolas; Devolites, Jennifer L.; Hart, Jeremy J.; Estes, Jay N.; Gaddis, Gregory S.
2014-01-01
The Autonomous precision Landing and Hazard Avoidance Technology (ALHAT) project has developed a suite of prototype sensors for enabling autonomous and safe precision land- ing of robotic or crewed vehicles on solid solar bodies under varying terrain lighting condi- tions. The sensors include a Lidar-based Hazard Detection System (HDS), a multipurpose Navigation Doppler Lidar (NDL), and a long-range Laser Altimeter (LAlt). Preparation for terrestrial ight testing of ALHAT onboard the Morpheus free- ying, rocket-propelled ight test vehicle has been in progress since 2012, with ight tests over a lunar-like ter- rain eld occurring in Spring 2014. Signi cant work e orts within both the ALHAT and Morpheus projects has been required in the preparation of the sensors, vehicle, and test facilities for interfacing, integrating and verifying overall system performance to ensure readiness for ight testing. The ALHAT sensors have undergone numerous stand-alone sensor tests, simulations, and calibrations, along with integrated-system tests in special- ized gantries, trucks, helicopters and xed-wing aircraft. A lunar-like terrain environment was constructed for ALHAT system testing during Morpheus ights, and vibration and thermal testing of the ALHAT sensors was performed based on Morpheus ights prior to ALHAT integration. High- delity simulations were implemented to gain insight into integrated ALHAT sensors and Morpheus GN&C system performance, and command and telemetry interfacing and functional testing was conducted once the ALHAT sensors and electronics were integrated onto Morpheus. This paper captures some of the details and lessons learned in the planning, preparation and integration of the individual ALHAT sen- sors, the vehicle, and the test environment that led up to the joint ight tests.
NASA Technical Reports Server (NTRS)
Kaufman, A.
1982-01-01
The on-site system application analysis is summarized. Preparations were completed for the first test of a full-sized single cell. Emphasis of the methanol fuel processor development program shifted toward the use of commercial shell-and-tube heat exchangers. An improved method for predicting the carbon-monoxide tolerance of anode catalysts is described. Other stack support areas reported include improved ABA bipolar plate bonding technology, improved electrical measurement techniques for specification-testing of stack components, and anodic corrosion behavior of carbon materials.
Technology Reinvestment Project Manufacturing Education and Training. Volume 1
NASA Technical Reports Server (NTRS)
Schroer, Bernard J.; Bond, Arthur J.
1997-01-01
The manufacturing education program is a joint program between the University of Alabama in Huntsville's (UAH) College of Engineering and Alabama A&M University's (AAMLJ) School of Engineering and Technology. The objective of the program is to provide more hands-on experiences to undergraduate engineering and engineering technology students. The scope of work consisted of. Year 1, Task 1: Review courses at Alabama Industrial Development Training (AIDT); Task 2: Review courses at UAH and AAMU; Task 3: Develop new lab manuals; Task 4: Field test manuals; Task 5: Prepare annual report. Year 2, Task 1: Incorporate feedback into lab manuals; Task 2 : Introduce lab manuals into classes; Task 3: Field test manuals; Task 4: Prepare annual report. Year 3, Task 1: Incorporate feedback into lab manuals; Task 2: Introduce lab manuals into remaining classes; Task 3: Conduct evaluation with assistance of industry; Task 4: Prepare final report. This report only summarizes the activities of the University of Alabama in Huntsville. The activities of Alabama A&M University are contained in a separate report.
Slice&Dice: Recognizing Food Preparation Activities Using Embedded Accelerometers
NASA Astrophysics Data System (ADS)
Pham, Cuong; Olivier, Patrick
Within the context of an endeavor to provide situated support for people with cognitive impairments in the kitchen, we developed and evaluated classifiers for recognizing 11 actions involved in food preparation. Data was collected from 20 lay subjects using four specially designed kitchen utensils incorporating embedded 3-axis accelerometers. Subjects were asked to prepare a mixed salad in our laboratory-based instrumented kitchen environment. Video of each subject's food preparation activities were independently annotated by three different coders. Several classifiers were trained and tested using these features. With an overall accuracy of 82.9% our investigation demonstrated that a broad set of food preparation actions can be reliably recognized using sensors embedded in kitchen utensils.
Reducing Adverse Impact: One City's Efforts.
ERIC Educational Resources Information Center
Prewitt, Jeff
Following a workshop on "Innovations in Employment Testing that Improve Validity and Reduce Adverse Impact," the City of Louisville (Kentucky) implemented a strategy to develop a comprehensive testing and recruiting program for police recruits. To improve candidate expectations and preparation, the following activities were undertaken:…
AEOLUS mission: the latest preparations before launch
NASA Astrophysics Data System (ADS)
Culoma, A.; Elfving, A.; Meynart, R.; Straume, A.; Wernham, D.
2017-09-01
The European Space Agency is developing a direct detection Doppler Wind Lidar for measuring wind profiles from space. The main objective of Aeolus is to provide tropospheric and lower stratospheric wind profiles globally for the improvement of weather forecast on short and medium term. Aeolus data are expected to greatly contribute to weather and air quality monitoring and to scientific advances in atmospheric dynamics. The UV Lidar instrument, ALADIN, will deliver horizontally-projected single line-of-sight wind profiles from the Doppler shift of molecular and particle backscatter. The development of the AEOLUS mission passed a major milestone with the integration of the full instrument and its functional and performance tests in 2016 and a 6-month life test of the spare UV laser transmitter. The satellite has been assembled and has successfully been subjected to a programme of functional and environmental (vibration, acoustic, shock, EMC) tests. The preparation of thermal vacuum testing, including instrument performance in vacuum, is close to completion.
Systematic Review of Plant-Based Homeopathic Basic Research: An Update.
Ücker, Annekathrin; Baumgartner, Stephan; Sokol, Anezka; Huber, Roman; Doesburg, Paul; Jäger, Tim
2018-05-01
Plant-based test systems have been described as a useful tool for investigating possible effects of homeopathic preparations. The last reviews of this research field were published in 2009/2011. Due to recent developments in the field, an update is warranted. Publications on plant-based test systems were analysed with regard to publication quality, reproducibility and potential for further research. A literature search was conducted in online databases and specific journals, including publications from 2008 to 2017 dealing with plant-based test systems in homeopathic basic research. To be included, they had to contain statistical analysis and fulfil quality criteria according to a pre-defined manuscript information score (MIS). Publications scoring at least 5 points (maximum 10 points) were assumed to be adequate. They were analysed for the use of adequate controls, outcome and reproducibility. Seventy-four publications on plant-based test systems were found. Thirty-nine publications were either abstracts or proceedings of conferences and were excluded. From the remaining 35 publications, 26 reached a score of 5 or higher in the MIS. Adequate controls were used in 13 of these publications. All of them described specific effects of homeopathic preparations. The publication quality still varied: a substantial number of publications (23%) did not adequately document the methods used. Four reported on replication trials. One replication trial found effects of homeopathic preparations comparable to the original study. Three replication trials failed to confirm the original study but identified possible external influencing factors. Five publications described novel plant-based test systems. Eight trials used systematic negative control experiments to document test system stability. Regarding research design, future trials should implement adequate controls to identify specific effects of homeopathic preparations and include systematic negative control experiments. Further external and internal replication trials, and control of influencing factors, are needed to verify results. Standardised test systems should be developed. The Faculty of Homeopathy.
ERIC Educational Resources Information Center
Gill, Clark C.; Conroy, William B.
The Latin America Project (1966-69) consisted of two phases: (1) completion of background studies and (2) preparation, field testing, and evaluation of instructional materials. Five background bulletins were prepared and distributed (See ED 012 832, ED 012 833, ED 012 365, ED 013 342, ED 022 781) and instructional materials organized around…
ERIC Educational Resources Information Center
Wetzel, Melissa Mosley; Hoffman, James V.; Roach, Audra K.; Russell, Katie
2018-01-01
This longitudinal study explores how one university's practice-based teacher preparation program prepared literacy teachers to develop practical knowledge for teaching and how that knowledge was tested and adapted in the first years of teaching. To understand change, we identified and analyzed points of tension, challenge, or dissonance in the…
40 CFR 1065.405 - Test engine preparation and maintenance.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 33 2011-07-01 2011-07-01 false Test engine preparation and...) AIR POLLUTION CONTROLS ENGINE-TESTING PROCEDURES Engine Selection, Preparation, and Maintenance § 1065.405 Test engine preparation and maintenance. This part 1065 describes how to test engines for a...
40 CFR 1065.405 - Test engine preparation and maintenance.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 32 2010-07-01 2010-07-01 false Test engine preparation and...) AIR POLLUTION CONTROLS ENGINE-TESTING PROCEDURES Engine Selection, Preparation, and Maintenance § 1065.405 Test engine preparation and maintenance. This part 1065 describes how to test engines for a...
Moody, Colleen A.; Eckel, Stephen F.; Amerine, Lindsey B.
2015-01-01
Background: Microbial contamination of compounded medications is a serious concern within hospital pharmacies as it can lead to severe patient injury. The United States Pharmacopeia <797> mandates that pharmacy personnel responsible for preparing compounded sterile preparations must annually demonstrate competency in aseptic technique by performing a media-fill challenge test. Objective: The purpose of this study is to evaluate the sensitivity of a commonly used media-fill test through proper and improper compounding techniques. Methods: Two aseptically trained pharmacy technicians performed media-fill challenge testing by carrying out 5 separate manipulations 5 times each for a total of 25 trials. Sterile vials, syringes, and intravenous bags were prepared. The first manipulation followed best-practice aseptic technique and sterile compounding procedures. Each of the following 4 manipulations removed one aspect of best-practice aseptic technique. The prepared products were incubated at 20°C to 25°C. A positive result for microbial contamination is indicated by visible turbidity within the vials, syringes, and intravenous bags at the following check points: 24 hours, 72 hours, 7 days, 14 days, 21 days, and >30 days. Results: Twenty-five trials, each containing 10 distinct admixtures, resulted in a total of 250 compounded preparations. No single preparation showed signs of turbidity, sedimentation, or visible microbial growth at any of the 6 checkpoints yielding a 0% contamination rate. However, the positive controls inoculated with bacteria did have positive microbial growth results. Conclusion: A more sensitive test needs to be developed to provide assurances that all poor aseptic practices are detected in compounding personnel.
Initial flight test of a Loran-C receiver/data collection system
NASA Technical Reports Server (NTRS)
Fischer, J. P.; Nickum, J. D.
1978-01-01
Development of a low cost Loran C receiver for general aviation use is discussed. The preparation and procedure of a flight test conducted with a receiver design which utilizes a phase locked loop oscillator to track the Loran C signals is described. It is indicated that such a receiver is a viable alternative for future work in developing a low cost Loran-C navigator.
Rotary Engine Friction Test Rig Development Report
2011-12-01
fundamental research is needed to understand the friction characteristics of the rotary engine that lead to accelerated wear and tear on the seals...that includes a turbocharger . Once the original GT-Suite model is validated, the turbocharger model will be more accurate. This validation will...prepare for turbocharger and fuel-injector testing, which will lead to further development and calibration of the model. Further details are beyond the
Annual Research Progress Report.
1979-09-30
will be trained in SLRL test procedures and the methodology will be developed for the incorporation of test materials into the standard rearing diet ...requirements exist for system software maintenance and development of software to report dosing data, to calculate diet preparation data, to manage collected...influence of diet and exercise on myo- globin and metmyoglobin reductase were evaluated in the rat. The activity of inetmyo- globin reductase was
Lab-on-a-Chip Application Development-Portable Test System (LOCAD) Phase 2
2009-03-21
ISS018-E-041370 (21 March 2009) --- Astronaut Sandra Magnus, STS-119 mission specialist, prepares to work with the Lab-on-a-Chip Application Development-Portable Test System (LOCAD-PTS) experiment in the Destiny laboratory while Space Shuttle Discovery remains docked with the International Space Station. LOCAD-PTS is a handheld device for rapid detection of biological and chemical substances onboard the station.
Managers Handbook for Software Development
NASA Technical Reports Server (NTRS)
Agresti, W.; Mcgarry, F.; Card, D.; Page, J.; Church, V.; Werking, R.
1984-01-01
Methods and aids for the management of software development projects are presented. The recommendations are based on analyses and experiences with flight dynamics software development. The management aspects of organizing the project, producing a development plan, estimation costs, scheduling, staffing, preparing deliverable documents, using management tools, monitoring the project, conducting reviews, auditing, testing, and certifying are described.
46 CFR 170.185 - Stability test preparations.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 7 2010-10-01 2010-10-01 false Stability test preparations. 170.185 Section 170.185....185 Stability test preparations. The following preparations must be made before conducting a stability... of the vessel to be tested. (2) Date and location of the test. (3) Inclining weight data. (4...
A Study on the English Language Teachers' Preparation of Tests
ERIC Educational Resources Information Center
Saricoban, Arif
2011-01-01
In this article the researcher has examined the current situation in test (a) construction: designing, structuring, developing, (b) administering, and (c) assessing the foreign language tests to see if we are still at the same point (traditional) and has given some suggestions on this indispensable issue. To collect the necessary data the 4th year…
ERIC Educational Resources Information Center
Hopley, Ken; And Others
The first of several planned volumes of Free Response Test Items contains geology questions developed by the Assessment and Evaluation Unit of the New South Wales Department of Education. Two additional geology volumes and biology and chemistry volumes are in preparation. The questions in this volume were written and reviewed by practicing…
Student Perceptions of the Progress Test in Two Settings and the Implications for Test Deployment
ERIC Educational Resources Information Center
Wade, Louise; Harrison, Chris; Hollands, James; Mattick, Karen; Ricketts, Chris; Wass, Val
2012-01-01
Background: The Progress Test (PT) was developed to assess student learning within integrated curricula. Whilst it is effective in promoting and rewarding deep approaches to learning in some settings, we hypothesised that implementation of the curriculum (design and assessment) may impact on students' preparation for the PT and their learning.…
Should patients with ocular genetic disorders have genetic testing?
Zanolli, Mario T; Khetan, Vikas; Dotan, Gad; Pizzi, Laura; Levin, Alex V
2014-09-01
To discuss the risks, benefits and value of genetic testing for ocular genetic disease. Testing for ocular genetics diseases is becoming more available and successful gene therapy is being reported. Clinicians must prepare for this trend by considering diagnostic genetic testing for their patients. As advances continually occur in genetic testing for ocular genetic disorders, clinicians must develop an understanding of the potential risks and benefits for their patients.
Detection of Ophiocordyceps sinensis and Its Common Adulterates Using Species-Specific Primers
Liu, Yang; Wang, Xiao-yue; Gao, Zi-tong; Han, Jian-ping; Xiang, Li
2017-01-01
Ophiocordyceps sinensis is a fungus that infects Hepialidae caterpillars, mummifying the larvae and producing characteristic fruiting bodies (stromata) that are processed into one of the most valued traditional Chinese medicines (TCM). The product commands a very high price due to a high demand but a very limited supply. Adulteration with other fungi is a common problem and there is a need to test preparation for the presence of the correct fungus. In the current study, a PCR-based approach for the identification of O. sinensis based on a segment of the internal transcribed spacer (ITS) region was developed. The segments is 146-bp in size and is likely to be amplified even in materials where processing led to DNA fragmentation. Primer development was based on the alignment of sequence data generated from a total of 89 samples of O. sinensis and potential adulterants as well as sequences date from 41 Ophiocordyceps species and 26 Cordyceps species available in GenBank. Tests with primer pair, DCF4/DCR4, demonstrated generation of an amplicon from DNA extracted from O. sinensis stromata, but not from extracts derived from adulterants. Species-specific primer pairs were also developed and tested for detection of the common adulterants, Cordyceps gunnii, Cordyceps cicadae, Cordyceps militaris, Cordyceps liangshanensis and Ophiocordyceps nutans. The collection of primers developed in the present study will be useful for the authentication of preparation claiming to only contain O. sinensis and for the detection of fungi used as adulterants in these preparations. PMID:28680424
ERIC Educational Resources Information Center
Professional Examination Service, New York, NY.
Criterion-referenced proficiency examinations have been prepared for entry level occupational therapists and entry level occupational therapy assistants. Item development was based on a task inventory solicited from occupational therapists throughout the country, with six occupational therapists reviewing test development. A small scale pilot test…
SRB Processing Facilities Media Event
2016-03-01
Members of the news media watch as two cranes are used to lift one of two pathfinders, or test versions, of solid rocket booster segments for NASA’s Space Launch System (SLS) rocket into the vertical position inside the Rotation, Processing and Surge Facility at NASA’s Kennedy Space Center in Florida. The pathfinder booster segment will be moved to the other end of the RPSF and secured on a test stand. The Ground Systems Development and Operations Program and Jacobs Engineering, on the Test and Operations Support Contract, will prepare the booster segments, which are inert, for a series of lifts, moves and stacking operations to prepare for Exploration Mission-1, deep-space missions and the journey to Mars.
Developing Multiple Choice Tests: Tips & Techniques
ERIC Educational Resources Information Center
McCowan, Richard J.
1999-01-01
Item writing is a major responsibility of trainers. Too often, qualified staff who prepare lessons carefully and teach conscientiously use inadequate tests that do not validly reflect the true level of trainee achievement. This monograph describes techniques for constructing multiple-choice items that measure student performance accurately. It…
ERIC Educational Resources Information Center
Kerr, Jon
2015-01-01
In 2013, as new high school equivalency exams were being developed and implemented across the nation and states were deciding which test was best for their population, Washington state identified the need to adopt the most rigorous test so that preparation to take it would equip students with the skills to be able to move directly from adult…
Refurbishment of SRB aluminum components by walnut hull blast removal of protective coatings
NASA Technical Reports Server (NTRS)
Colberg, W. R.; Gordon, G. H.; Jackson, C. H.
1982-01-01
A test program was conducted to develop, optimize, and scale up an abrasive blasting procedure was developed for refurbishment of specific SRB components: aft skirt, forward skirt, frustrum, and painted piece parts. Test specimens utilizing 2219 T87 aluminum substrate of varying thicknesses were prepared and blasted at progressively increasing pressures with selected abrasives. Specimens were analyzed for material response. The optimum blasting parameters were determined on panel specimens and verified on a large cylindrical integrated test bed.
NASA Astrophysics Data System (ADS)
Dwi Cahyono, Bagus; Ainur, Chandra
2018-04-01
The development of science and technology has a direct impact on the preparation of qualified workers, including the preparation of vocational high school graduates. Law Number 20 the Year 2003 on National Education System explains that the purpose of vocational education is to prepare learners to be ready to work in certain fields. One of the learning materials in Vocational High School is welding and detecting welding defects. Introduction of welding and detecting welding defects, one way that can be done is by ultrasonic testing will be very difficult if only capitalize the book only. Therefore this study aims to adopt ultrasonic testing in a computer system. This system is called Delphi Program-based Ultrasonic Testing Expert System. This system is used to determine the classification and type of welding defects of the welded defect indicator knew. In addition to the system, there is a brief explanation of the notion of ultrasonic testing, calibration procedures and inspection procedures ultrasonic testing. In this system, ultrasonic input data testing that shows defects entered into the computer manually. This system is built using Delphi 7 software and Into Set Up Compiler as an installer. The method used in this research is Research and Development (R & D), with the following stages: (1) preliminary research; (2) manufacture of software design; (3) materials collection; (4) early product development; (5) validation of instructional media experts; (6) product analysis and revision; (8) media trials in learning; And (9) result of end product of instructional media. The result of the research shows that: (1) the result of feasibility test according to ultrasonic material testing expert that the system is feasible to be used as instructional media in welding material subject and welding defect detection in vocational education environment, because it contains an explanation about detection method of welding defect using method Ultrasonic testing in detail; (2) feasibility test results according to media experts, that this system has a very attractive visual, user friendly, compatible with windows and Linux and media size that is not too large; And (3) result of test by using data of indication of welding defect in PT PAL Surabaya, obtained classification data of welding defect in accordance with calculation of welding defect classification.
Summary of Stirling Convertor Testing at NASA Glenn Research Center
NASA Technical Reports Server (NTRS)
Schreiber, Jeffrey G.
2006-01-01
The NASA Glenn Research Center (GRC) has been testing free-piston Stirling convertors for potential use in radioisotope power systems. These convertors tend to be in the 35 to 80 W electric power output range. Tests at GRC have accumulated over 80,000 hr of operation. Test articles have been received from Infinia Corporation of Kennewick, Washington and from Sunpower of Athens, Ohio. Infinia designed and built the developmental Stirling Technology Demonstration Convertors (TDC) in addition to the more advanced Test Bed and Engineering Unit convertors. GRC has eight of the TDC's under test including two that operate in a thermal vacuum environment. Sunpower designed and developed the EE-35 and the Advanced Stirling Convertor (ASC). GRC has six of the EE- 35 s and is preparing for testing multiple ASC s. Free-piston Stirling convertors for radioisotope power systems make use of non-contacting operation that eliminates wear and is suited for long-term operation. Space missions with radioisotope power systems are often considered that extend from three to 14 years. One of the key capabilities of the GRC test facility is the ability to support continuous, unattended operation. Hardware, software, and procedures for preparing the test articles were developed to support these tests. These included the processing of the convertors for minimizing the contaminants in the working fluid, developing a helium charging system for filling and for gas sample analysis, and the development of new control software and a high-speed protection circuit to insure safe, round-the-clock operation. Performance data of Stirling convertors over time is required to demonstrate that a radioisotope power system is capable of providing reliable power for multi-year missions. This paper will discuss the status of Stirling convertor testing at GRC.
Summary of Stirling Convertor Testing at GRC
NASA Technical Reports Server (NTRS)
Schreiber, Jeffrey G.
2006-01-01
The NASA Glenn Research Center (GRC) has been testing free-piston Stirling convertors for potential use in radioisotope power systems. These convertors tend to be in the 35 to 80 watt electric power output range. Tests at GRC have accumulated over 80,000 hours of operation. Test articles have been received from Infinia Corporation of Kennewick, WA and from Sunpower of Athens, OH. Infinia designed and built the developmental Stirling Technology Demonstration Convertors (TDC) in addition to the more advanced Test Bed and Engineering Unit convertors. GRC has eight of the TDC's under test including two that operate in a thermal vacuum environment. Sunpower designed and developed the EE- 35 and the Advanced Stirling Convertor (ASC). GRC has six of the EE-35's and is preparing for testing multiple ASC's. Free-piston Stirling convertors for radioisotope power systems make use of non-contacting operation that eliminates wear and is suited for longterm operation. Space missions with radioisotope power systems are often considered that extend from three to 14 years. One of the key capabilities of the GRC test facility is the ability to support continuous, unattended operation. Hardware, software, and procedures for preparing the test articles were developed to support these tests. These included the processing of the convertors for minimizing the contaminants in the working fluid, developing a helium charging system for filling and for gas sample analysis, and the development of new control software and a high-speed protection circuit to insure safe, round-the-clock operation. Performance data of Stirling convertors over time is required to demonstrate that a radioisotope power system is capable of providing reliable power for multi-year missions. This paper will discuss the status of Stirling convertor testing at GRC.
Ozay, Guner; Seyhan, Ferda; Yilmaz, Aysun; Whitaker, Thomas B; Slate, Andrew B; Giesbrecht, Francis
2006-01-01
The variability associated with the aflatoxin test procedure used to estimate aflatoxin levels in bulk shipments of hazelnuts was investigated. Sixteen 10 kg samples of shelled hazelnuts were taken from each of 20 lots that were suspected of aflatoxin contamination. The total variance associated with testing shelled hazelnuts was estimated and partitioned into sampling, sample preparation, and analytical variance components. Each variance component increased as aflatoxin concentration (either B1 or total) increased. With the use of regression analysis, mathematical expressions were developed to model the relationship between aflatoxin concentration and the total, sampling, sample preparation, and analytical variances. The expressions for these relationships were used to estimate the variance for any sample size, subsample size, and number of analyses for a specific aflatoxin concentration. The sampling, sample preparation, and analytical variances associated with estimating aflatoxin in a hazelnut lot at a total aflatoxin level of 10 ng/g and using a 10 kg sample, a 50 g subsample, dry comminution with a Robot Coupe mill, and a high-performance liquid chromatographic analytical method are 174.40, 0.74, and 0.27, respectively. The sampling, sample preparation, and analytical steps of the aflatoxin test procedure accounted for 99.4, 0.4, and 0.2% of the total variability, respectively.
Orion's Neutral Buoyancy Lab (NBL) Activities
2016-09-21
U.S. Navy divers are training in the Neutral Buoyancy Laboratory at NASA’s Johnson Space Center in Houston. Navy divers, Air Force pararescuemen and Coast Guard rescue swimmers practice Orion underway recovery techniques using a test version of the Orion spacecraft. Training will help the team prepare for Underway Recovery Test 5 for Exploration Mission 1 aboard the USS San Diego in the Pacific Ocean off the coast of California in October. The Ground Systems Development and Operations Program, along with the U.S. Navy and Lockheed Martin, are preparing the recovery team, hardware and operations to support EM-1 recovery.
Development of a space stable thermal control coatings for use in large space vehicles
NASA Technical Reports Server (NTRS)
Gilligan, J. E.; Ashford, N. A.; Harada, Y.; Leas, R. M.
1971-01-01
The preparation and evaluation of zinc orthotitanate and of several new pigments and the environmental testing and evaluation of these pigments and of coatings made from them constitute the bulk of the work accomplished. New pigments were prepared and EPR spectra of pigments and their precursor compounds studied. Results of extensive testing of commercially-available, strippable, protective coatings are reported; Owens-Illinois 650 glass resin has been stabilized against progressive mechanical failures; and definite improvements have been noted. A zinc oxide pigmented lithium silicate paint has demonstrated very good ultraviolet stability.
A Standard Psychophysiological Preparation (SPP) for the evaluation of the physiological and biomechanical mechanisms responsible for performance...consumption, biomechanical parameters and performance level. The results of pilot tests (including 6-hours exposure to vibration while performing a...tracking task) verify the applicability and utility of the SPP and demonstrate that high quality, quantitative physiological and biomechanical data can
M.D. Cain; M.G. Shelton
2001-01-01
Three opening sizes (0.25, 0.625, and 1.0 ac) and three site preparation methods (herbicides, mechanical, and an untreated control) were tested in a pine-hardwood stand dominated by loblolly and shortleaf pines (Pinus taeda L. and P. echinata Mill.) and mixed oaks (Quercus spp.) that was being converted to uneven...
Reference Proteome Extracts for Mass Spec Instrument Performance Validation and Method Development
Rosenblatt, Mike; Urh, Marjeta; Saveliev, Sergei
2014-01-01
Biological samples of high complexity are required to test protein mass spec sample preparation procedures and validate mass spec instrument performance. Total cell protein extracts provide the needed sample complexity. However, to be compatible with mass spec applications, such extracts should meet a number of design requirements: compatibility with LC/MS (free of detergents, etc.)high protein integrity (minimal level of protein degradation and non-biological PTMs)compatibility with common sample preparation methods such as proteolysis, PTM enrichment and mass-tag labelingLot-to-lot reproducibility Here we describe total protein extracts from yeast and human cells that meet the above criteria. Two extract formats have been developed: Intact protein extracts with primary use for sample preparation method development and optimizationPre-digested extracts (peptides) with primary use for instrument validation and performance monitoring
Study Guide for TCT in Health Education.
ERIC Educational Resources Information Center
Wilks, Barbara
This study guide was specifically designed for individuals preparing to take the Georgia Teacher Certification Test (TCT) in health education. The test covers eight subareas: (1) personal health; (2) nutrition; (3) human growth and development; (4) human sexuality and family living; (5) drugs; (6) safety, first aid, and emergency treatment; (7)…
SMD 3 post test medical report
NASA Technical Reports Server (NTRS)
Hordinsky, J. R.
1977-01-01
One of several reports that were prepared to document the results of the Spacelab Mission Development Test 3 is presented. This report covers clinical support to the crew as well as assistance and counsel to others in crew selection, health stabilization of the crew and the laboratory animals, and habitability and duty schedules.
Critical Thinking: More than Test Scores
ERIC Educational Resources Information Center
Smith, Vernon G.; Szymanski, Antonia
2013-01-01
This article is for practicing or aspiring school administrators. The demand for excellence in public education has lead to an emphasis on standardized test scores. This article explores the development of a professional enhancement program designed to prepare teachers to teach higher order thinking skills. Higher order thinking is the primary…
Study Guide for TCT in Science.
ERIC Educational Resources Information Center
Clark, Gene
This study guide was developed for individuals preparing to take the Georgia Teacher Certification Test (TCT) in science. Content objectives of the test are listed and encompass: (1) scientific processes, research, and classification; (2) earth sciences; (3) characteristics and properties of matter, energy, and chemical change; (4) biology of life…
Study Guide for TCT in Health and Physical Education.
ERIC Educational Resources Information Center
Mullan, Marie R.
This study guide is designed for those individuals preparing to take the Georgia Teacher Certification Test (TCT) in health and physical education. The test covers nine broad subareas: (1) health, body systems, disease; (2) tennis, handball, fencing, bowling, track, and recreational games; (3) development, hygiene, safety, nutrition; (4) softball,…
ERIC Educational Resources Information Center
Summerskill, John
The Educational Passport is a service that is being developed at the Educational Testing Service for students or other individuals in order to facilitate their entry to school or college or employment. The Passport is an accumulative record that the individual prepares and owns and uses. At the Educational Testing Service, photographed documents…
Teaching Psychological Assessment: Training Issues and Teaching Approaches.
ERIC Educational Resources Information Center
Russ, Sandra W.
1978-01-01
Graduate psychology students are not as well prepared as many internship supervisors would like. Students need help in dealing with issues of categorizing individuals, using tests, taking responsibility, and developing a balance between critical evaluation of tests and appreciation of their usefulness. Approaches for dealing with these issues are…
A Curriculum for Preparing Science Teachers to Use Microcomputers.
ERIC Educational Resources Information Center
Ellis, James D.; Kuerbis, Paul J.
1991-01-01
ENLIST Micros, a project designed to improve quality and quantity of microcomputer use in science teaching, is described. Rationale and procedures behind its development; description of the pilot test model; results of the initial field test and an implementation study; description of the revised ENLIST Micros curriculum; and recommendations for…
Experiments with Cloze Procedure
ERIC Educational Resources Information Center
Evans, Gordon; Haastrup, Kirsten
1976-01-01
The Nordic Test Development Group prepared proficiency tests of English designed to provide reliable information on which to base decisions as to whether a candidate would be able to function in a job as described or whether he could be trained to do so. Two subtests used a modified cloze procedure. (Author/CFM)
Uranium nitride fuel fabrication for SP-100 reactors
NASA Technical Reports Server (NTRS)
Mason, Richard E.; Chidester, Kenneth M.; Hoth, Carl W.; Matthews, Bruce R.
1987-01-01
Fuel pins of uranium mononitride clad in Nb-1 percent Zr were fabricated for irradiation tests in EBR-II. Laboratory scale process parameters to synthesize UN powders and fabricate UN pellets were developed. Uranium mononitride was prepared by converting UO2 to UN. Fuel pellets were prepared by communition of UN briquettes, uniaxial pressing, and high temperature sintering. Techniques for machining, cleaning, and welding Nb-1 percent Zr cladding components were developed. End caps were electron beam welded to the tubing. Helium back-fill holes were sealed with a laser weld.
Uranium nitride fuel fabrication for SP-100 reactors
NASA Astrophysics Data System (ADS)
Mason, Richard E.; Chidester, Kenneth M.; Hoth, Carl W.; Matthews, Bruce R.
Fuel pins of uranium mononitride clad in Nb-1 percent Zr were fabricated for irradiation tests in EBR-II. Laboratory scale process parameters to synthesize UN powders and fabricate UN pellets were developed. Uranium mononitride was prepared by converting UO2 to UN. Fuel pellets were prepared by communition of UN briquettes, uniaxial pressing, and high temperature sintering. Techniques for machining, cleaning, and welding Nb-1 percent Zr cladding components were developed. End caps were electron beam welded to the tubing. Helium back-fill holes were sealed with a laser weld.
A ricin forensic profiling approach based on a complex set of biomarkers.
Fredriksson, Sten-Åke; Wunschel, David S; Lindström, Susanne Wiklund; Nilsson, Calle; Wahl, Karen; Åstot, Crister
2018-08-15
A forensic method for the retrospective determination of preparation methods used for illicit ricin toxin production was developed. The method was based on a complex set of biomarkers, including carbohydrates, fatty acids, seed storage proteins, in combination with data on ricin and Ricinus communis agglutinin. The analyses were performed on samples prepared from four castor bean plant (R. communis) cultivars by four different sample preparation methods (PM1-PM4) ranging from simple disintegration of the castor beans to multi-step preparation methods including different protein precipitation methods. Comprehensive analytical data was collected by use of a range of analytical methods and robust orthogonal partial least squares-discriminant analysis- models (OPLS-DA) were constructed based on the calibration set. By the use of a decision tree and two OPLS-DA models, the sample preparation methods of test set samples were determined. The model statistics of the two models were good and a 100% rate of correct predictions of the test set was achieved. Copyright © 2018 Elsevier B.V. All rights reserved.
ERIC Educational Resources Information Center
Moshinsky, Avital; Ziegler, David; Gafni, Naomi
2017-01-01
Many medical schools have adopted multiple mini-interviews (MMI) as an advanced selection tool. MMIs are expensive and used to test only a few dozen candidates per day, making it infeasible to develop a different test version for each test administration. Therefore, some items are reused both within and across years. This study investigated the…
ERIC Educational Resources Information Center
Gutl, Christian; Lankmayr, Klaus; Weinhofer, Joachim; Hofler, Margit
2011-01-01
Research in automated creation of test items for assessment purposes became increasingly important during the recent years. Due to automatic question creation it is possible to support personalized and self-directed learning activities by preparing appropriate and individualized test items quite easily with relatively little effort or even fully…
EU Regulation of Nanobiocides: Challenges in Implementing the Biocidal Product Regulation (BPR).
Brinch, Anna; Hansen, Steffen Foss; Hartmann, Nanna B; Baun, Anders
2016-02-16
The Biocidal Products Regulation (BPR) contains several provisions for nanomaterials (NMs) and is the first regulation in the European Union to require specific testing and risk assessment for the NM form of a biocidal substance as a part of the information requirements. Ecotoxicological data are one of the pillars of the information requirements in the BPR, but there are currently no standard test guidelines for the ecotoxicity testing of NMs. The overall objective of this work was to investigate the implications of the introduction of nano-specific testing requirements in the BPR and to explore how these might be fulfilled in the case of copper oxide nanoparticles. While there is information and data available in the open literature that could be used to fulfill the BPR information requirements, most of the studies do not take the Organisation for Economic Co-operation and Development's nanospecific test guidelines into consideration. This makes it difficult for companies as well as regulators to fulfill the BPR information requirements for nanomaterials. In order to enable a nanospecific risk assessment, best practices need to be developed regarding stock suspension preparation and characterization, exposure suspensions preparation, and for conducting ecotoxicological test.
Takai, K; Soejima, T; Suzuki, T; Kawazu, K
2001-05-01
Water-soluble preparations have been investigated to develop a trunk injection agent based on the poorly water-soluble anti-nematode emamectin benzoate. Following tests on the phytotoxicity of some solvents and solubilizers and demonstration of the ability of some solubilizers to dissolve emamectin benzoate in water, acetone + methanol was selected as the solvent and Polysorbate 80 as the solubilizer. This water-soluble preparation of emamectin benzoate prevented the wilting of pot-grown 4-year-old trees of the Japanese black pine, Pinus thunbergii, artificially inoculated with the pine wood nematode, Bursaphelenchus xylophilus, at a dose of 20 g emamectin benzoate per cubic metre of pine tree.
Goldberg, Roger A; Flynn, Harry W; Miller, Darlene; Gonzalez, Serafin; Isom, Ryan F
2013-07-01
To report the 1-year clinical outcomes of an outbreak of Streptococcus endophthalmitis after intravitreal injection of bevacizumab, including visual acuity outcomes, microbiological testing, and compound pharmacy investigations by the Food and Drug Administration (FDA). Retrospective consecutive case series. Twelve eyes of 12 patients who developed endophthalmitis after receiving intravitreal bevacizumab prepared by a single compounding pharmacy. Medical records of patients were reviewed; phenotypic and DNA analyses were performed on microbes cultured from patients and from unused syringes. An inspection report by the FDA based on site visits to the pharmacy that prepared the bevacizumab syringes was summarized. Visual acuity, interventions received, time to intervention, microbiological consistency, and FDA inspection findings. Between July 5 and 8, 2011, 12 patients developed endophthalmitis after intravitreal bevacizumab from syringes prepared by a single compounding pharmacy. All patients received initial vitreous tap and injection, and 8 patients (67%) subsequently underwent pars plana vitrectomy (PPV). After 12 months follow-up, outcomes have been poor. Seven patients (58%) required evisceration or enucleation, and only 1 patient regained pre-injection visual acuity. Molecular testing using real-time polymerase chain reaction, partial sequencing of the groEL gene, and multilocus sequencing of 7 housekeeping genes confirmed the presence of a common strain of Streptococcus mitis/oralis in vitreous specimens and 7 unused syringes prepared by the compounding pharmacy at the same time. An FDA investigation of the compounding pharmacy noted deviations from standard sterile technique, inconsistent documentation, and inadequate testing of equipment required for safe preparation of medications. In this outbreak of endophthalmitis, outcomes have been generally poor, and PPV did not improve visual results at 1-year follow-up. Molecular testing confirmed a common strain of S. mitis/oralis. Contamination seems to have occurred at the compounding pharmacy, where numerous problems in sterile technique were noted by public health investigators. Copyright © 2013 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Goldberg, Roger A.; Flynn, Harry W.; Miller, Darlene; Gonzalez, Serafin; Isom, Ryan F.
2013-01-01
Purpose To report the one-year clinical outcomes of an outbreak of Streptococcus endophthalmitis after intravitreal injection of bevacizumab, including visual acuity outcomes, microbiological testing and compound pharmacy investigations by the Food and Drug Administration (FDA). Design Retrospective consecutive case series. Participants 12 eyes of 12 patients who developed endophthalmitis after receiving intravitreal bevacizumab prepared by a single compounding pharmacy. Methods Medical records of patients were reviewed; phenotypic and DNA analyses were performed on microbes cultured from patients and from unused syringes. An inspection report by the FDA based on site-visits to the pharmacy that prepared the bevacizumab syringes was summarized. Main Outcome Measures Visual acuity, interventions received, time-to-intervention; microbiological consistency; FDA inspection findings. Results Between July 5 and July 8, 2011, 12 patients developed endophthalmitis after intravitreal bevacizumab from syringes prepared by a single compounding pharmacy. All patients received initial vitreous tap and injection, and eight (67%) subsequently underwent pars plana vitrectomy (PPV). After twelve months follow-up, outcomes have been poor: 7 patients (58%) required evisceration or enucleation, and only one patient regained pre-injection visual acuity. Molecular testing using real time polymerase chain reaction, partial sequencing of the groEL gene, and multilocus sequencing of 7 housekeeping genes confirmed the presence of a common strain of Streptococcus mitis/oralis in vitreous specimens and seven unused syringes prepared by the compounding pharmacy at the same time. An FDA investigation of the compounding pharmacy noted deviations from standard sterile technique, inconsistent documentation, and inadequate testing of equipment required for safe preparation of medications. Conclusions In this outbreak of endophthalmitis, outcomes have been generally poor and PPV did not improve visual results at one year follow-up. Molecular testing confirmed a common strain of Streptococcus mitis/oralis. Contamination appears to have occurred at the compounding pharmacy, where numerous problems in sterile technique were noted by public health investigators. PMID:23453511
Cryogenic testing of Planck sorption cooler test facility
NASA Technical Reports Server (NTRS)
Zhang, B.; Pearson, D.; Borders, J.; Franklin, B.; Prina, M.; Hardy, J.; Crumb, D.
2004-01-01
A test facility has been upgraded in preparation for testing of two hydrogen sorption cryocoolers operating at 18/20 K. these sorption coolers are currently under development at the Jet Propulsion Laboratory. This work summarizes the scope of the test facility upgrade, including design for cryogenic cooling power delivery, system thermal management, insulation schemes, and data acquisition techniques. Ground support equipment for the sorption coolers, structural features of the test chamber, and the vacuum system involved for system testing will also be described in detail.
Hyperkalemia caused by rapid red cell transfusion and the potassium absorption filter
Imashuku, Yasuhiko; Kitagawa, Hirotoshi; Mizuno, Takayoshi; Fukushima, Yutaka
2017-01-01
We report a case of transient hyperkalemia during hysterectomy after cesarean section, due to preoperatively undiagnosed placenta accreta that caused unforeseen massive hemorrhage and required rapid red cell transfusion. Hyperkalemia-induced by rapid red cell transfusion is a well-known severe complication of transfusion; however, in patients with sudden massive hemorrhage, rapid red cell transfusion is necessary to save their life. In such cases, it is extremely important to monitor serum potassium levels. For an emergency situation, a system should be developed to ensure sufficient preparation for immediate transfusion and laboratory tests. Furthermore, sufficient stock of preparations to treat hyperkalemia, such as calcium preparations, diuretics, glucose, and insulin is required. Moreover, a transfusion filter that absorbs potassium has been developed and is now available for clinical use in Japan. The filter is easy to use and beneficial, and should be prepared when it is available. PMID:28217070
46 CFR 61.05-5 - Preparation of boilers for inspection and test.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 2 2010-10-01 2010-10-01 false Preparation of boilers for inspection and test. 61.05-5... PERIODIC TESTS AND INSPECTIONS Tests and Inspections of Boilers § 61.05-5 Preparation of boilers for... preparing the boilers for the hydrostatic test, they shall be filled with water at not less than 70 °F. and...
Targeted RNA-Sequencing with Competitive Multiplex-PCR Amplicon Libraries
Blomquist, Thomas M.; Crawford, Erin L.; Lovett, Jennie L.; Yeo, Jiyoun; Stanoszek, Lauren M.; Levin, Albert; Li, Jia; Lu, Mei; Shi, Leming; Muldrew, Kenneth; Willey, James C.
2013-01-01
Whole transcriptome RNA-sequencing is a powerful tool, but is costly and yields complex data sets that limit its utility in molecular diagnostic testing. A targeted quantitative RNA-sequencing method that is reproducible and reduces the number of sequencing reads required to measure transcripts over the full range of expression would be better suited to diagnostic testing. Toward this goal, we developed a competitive multiplex PCR-based amplicon sequencing library preparation method that a) targets only the sequences of interest and b) controls for inter-target variation in PCR amplification during library preparation by measuring each transcript native template relative to a known number of synthetic competitive template internal standard copies. To determine the utility of this method, we intentionally selected PCR conditions that would cause transcript amplification products (amplicons) to converge toward equimolar concentrations (normalization) during library preparation. We then tested whether this approach would enable accurate and reproducible quantification of each transcript across multiple library preparations, and at the same time reduce (through normalization) total sequencing reads required for quantification of transcript targets across a large range of expression. We demonstrate excellent reproducibility (R2 = 0.997) with 97% accuracy to detect 2-fold change using External RNA Controls Consortium (ERCC) reference materials; high inter-day, inter-site and inter-library concordance (R2 = 0.97–0.99) using FDA Sequencing Quality Control (SEQC) reference materials; and cross-platform concordance with both TaqMan qPCR (R2 = 0.96) and whole transcriptome RNA-sequencing following “traditional” library preparation using Illumina NGS kits (R2 = 0.94). Using this method, sequencing reads required to accurately quantify more than 100 targeted transcripts expressed over a 107-fold range was reduced more than 10,000-fold, from 2.3×109 to 1.4×105 sequencing reads. These studies demonstrate that the competitive multiplex-PCR amplicon library preparation method presented here provides the quality control, reproducibility, and reduced sequencing reads necessary for development and implementation of targeted quantitative RNA-sequencing biomarkers in molecular diagnostic testing. PMID:24236095
2013-12-04
CAPE CANAVERAL, Fla. – At NASA’s Kennedy Space Center in Florida, technicians prepare to load the Project Morpheus Prototype Lander with propellant at the launch platform located at the north end of the Shuttle Landing Facility. Morpheus is being prepared for a dress rehearsal of a tethered flight test. Testing of the prototype lander was performed at NASA’s Johnson Space Center in Houston in preparation for tethered and free flight testing at Kennedy. The landing facility will provide the lander with the kind of field necessary for realistic testing, complete with rocks, craters and hazards to avoid. Morpheus utilizes an autonomous landing and hazard avoidance technology, or ALHAT, payload that will allow it to navigate to clear landing sites amidst rocks, craters and other hazards during its descent. Project Morpheus is being managed under the Advanced Exploration Systems, or AES, Division in NASA’s Human Exploration and Operations Mission Directorate. The efforts in AES pioneer new approaches for rapidly developing prototype systems, demonstrating key capabilities and validating operational concepts for future human missions beyond Earth orbit. For more information on Project Morpheus, visit http://morpheuslander.jsc.nasa.gov. Photo credit: NASA/Kim Shiflett
Gonzales, J L; Loza, A; Chacon, E
2006-03-15
There are several T. vivax specific primers developed for PCR diagnosis. Most of these primers were validated under different DNA extraction methods and study designs leading to heterogeneity of results. The objective of the present study was to validate PCR as a diagnostic test for T. vivax trypanosomosis by means of determining the test sensitivity of different published specific primers with different sample preparations. Four different DNA extraction methods were used to test the sensitivity of PCR with four different primer sets. DNA was extracted directly from whole blood samples, blood dried on filter papers or blood dried on FTA cards. The results showed that the sensitivity of PCR with each primer set was highly dependant of the sample preparation and DNA extraction method. The highest sensitivities for all the primers tested were determined using DNA extracted from whole blood samples, while the lowest sensitivities were obtained when DNA was extracted from filter paper preparations. To conclude, the obtained results are discussed and a protocol for diagnosis and surveillance for T. vivax trypanosomosis is recommended.
Preparation of a Frozen Regolith Simulant Bed for ISRU Component Testing in a Vacuum Chamber
NASA Technical Reports Server (NTRS)
Klenhenz, Julie; Linne, Diane
2013-01-01
In-Situ Resource Utilization (ISRU) systems and components have undergone extensive laboratory and field tests to expose hardware to relevant soil environments. The next step is to combine these soil environments with relevant pressure and temperature conditions. Previous testing has demonstrated how to incorporate large bins of unconsolidated lunar regolith into sufficiently sized vacuum chambers. In order to create appropriate depth dependent soil characteristics that are needed to test drilling operations for the lunar surface, the regolith simulant bed must by properly compacted and frozen. While small cryogenic simulant beds have been created for laboratory tests, this scale effort will allow testing of a full 1m drill which has been developed for a potential lunar prospector mission. Compacted bulk densities were measured at various moisture contents for GRC-3 and Chenobi regolith simulants. Vibrational compaction methods were compared with the previously used hammer compaction, or "Proctor", method. All testing was done per ASTM standard methods. A full 6.13 m3 simulant bed with 6 percent moisture by weight was prepared, compacted in layers, and frozen in a commercial freezer. Temperature and desiccation data was collected to determine logistics for preparation and transport of the simulant bed for thermal vacuum testing. Once in the vacuum facility, the simulant bed will be cryogenically frozen with liquid nitrogen. These cryogenic vacuum tests are underway, but results will not be included in this manuscript.
Stability of fragrance patch test preparations applied in test chambers.
Mowitz, M; Zimerson, E; Svedman, C; Bruze, M
2012-10-01
Petrolatum patch test preparations are for practical reasons often applied in test chambers in advance, several hours or even days before the patient is tested. As many fragrance compounds are volatile it may be suspected that petrolatum preparations applied in test chambers are not stable over time. To investigate the stability of petrolatum preparations of the seven chemically defined components in the fragrance mix (FM I) when stored in test chambers. Samples of petrolatum preparations applied in test chambers stored at room temperature and in a refrigerator for between 4 and 144 h were analysed using liquid chromatographic methods. The concentration decreased by ≥ 20% within 8 h in four of seven preparations stored in Finn chambers at room temperature. When stored in a refrigerator only the preparation of cinnamal had decreased by ≥ 20% within 24 h. The stability of preparations of cinnamal stored in IQ chambers with a plastic cover was slightly better, but like the preparations applied in Finn chambers, the concentration decreased by ≥ 20% within 4 h at room temperature and within 24 h in a refrigerator. Cinnamal and cinnamyl alcohol were found to be more stable when analysed as ingredients in FM I compared with when analysed in individual preparations. Within a couple of hours several fragrance allergens evaporate from test chambers to an extent that may affect the outcome of the patch test. Application to the test chambers should be performed as close to the patch test occasion as possible and storage in a refrigerator is recommended. © 2012 The Authors. BJD © 2012 British Association of Dermatologists.
Gade, Anne Lill; Ovrebø, Steinar; Hylland, Ketil
2008-07-01
The goal of REACH is the safe use of chemicals. This study examines the efficiency and usefulness of two draft technical guidance notes in the REACH Interim Project 3.2-2 for the development of the chemical safety report and exposure scenarios. A case study was carried out for a paint system for protection of structural steel. The focuses of the study were risk assessment of preparations based on Derived No Effect Level (DNEL) and Predicted No Effect Concentrations (PNEC) and on effective and accurate communication in the supply chain. Exposure scenarios and generic descriptions of uses, risk management measures, and exposure determinants were developed. The study showed that communication formats, software tools, and guidelines for chemical risk assessment need further adjustment to preparations and real-life situations. Web platforms may simplify such communication. The downstream formulator needs basic substance data from the substance manufacturer during the pre-registration phase to develop exposure scenarios for preparations. Default values need to be communicated in the supply chain because these were critical for the derivation of applicable risk management demands. The current guidelines which rely on the available toxicological knowledge are insufficient to advise downstream users on how to develop exposure scenarios for preparations.
Final Technical/Scientific Report: Commodity Scale Thermostable Enzymatic Transformations
DOE Office of Scientific and Technical Information (OSTI.GOV)
James J. Lalonde; Brian Davison
2003-08-30
The conversion of corn starch to high fructose corn-syrup sweetener is a commodity process, producing over 3 billion kg/y. In the last step of the process, an enzyme catalyst is used to convert glucose to the much sweeter sugar fructose. Due to incomplete conversion in the last step, the syrup must be purified using a chromatographic separation technique, which results in equal quantities of water being added to the syrup, and finally the water must be evaporated (up to 1 lb of water/lb of syrup). We have estimated the energy requirement in the evaporation step to be on the ordermore » of 13 billion BTU's/y. This process inefficiency could be eliminated if a thermostable form of glucose isomerase (GI), the enzyme catalyst used in the final step, was developed. Our chosen strategy was to develop an immobilized form of the enzyme in which the protein is first crystallized and then chemically cross-linked to form an insoluble particle. This so-called cross-linked enzyme crystal (CLE C(reg. sign)) technology had been shown to be a powerful method for enzyme stabilization for several other protein catalysts. In this work we have developed more than 30 CLEC preparations of glucose isomerase and tested them for activity and stability. We found these preparations to be highly active, with a 10-50 fold rate per gram of catalyst increase over existing commercial catalysts. The initial rates were also higher at higher temperatures as expected, however the efficiency of the CLEC GI preparations unexpectedly rapidly decreased to a low constant value with use at the higher temperatures. At this point, the source of this activity loss is unclear, however during this loss, the catalyst is found to form a solid mass indicating either breakage of the chemical cross-links or simple aggregation of the particles. It is likely that the increased mass transfer resistance due to this agglomeration is a major component of the activity loss. This research suggests that one potentially beneficial outcome could be the reconfiguration of catalyst columns using these highly active catalyst preparations with inerts to prevent agglomeration. As a result of this work, methods for the preparation of highly active immobilized glucose isomerase preparations were developed along with test methods that are predictive for the stability of these preparations. This research has been conducted as a team effort. The enzyme is produced using Genencor's glucose isomerase protein and the stabilized form has been prepared using Altus' CLEC technology. ORNL has provided bioprocess engineering and testing expertise, and Cargill, Inc. and Genencor have supplied critical technical consultation and economic assessment.« less
Mateti, Uday Venkat; Nagappa, Anantha Naik; Attur, Ravindra Prabhu; Bairy, Manohar; Nagaraju, Shankar Prasad; Mallayasamy, Surulivelrajan; Vilakkathala, Rajesh; Guddattu, Vasudev; Balkrishnan, Rajesh
2015-11-01
Patient information leaflets are universally-accepted resources to educate the patients/users about their medications, disease and lifestyle modification. The objective of the study was to prepare, validate and perform user-testing of pictogram-based patient information leaflets (P-PILs) among hemodialysis (HD) patients. The P-PILs are prepared by referring to the primary, secondary and tertiary resources. The content and pictograms of the leaflet have been validated by an expert committee consisting of three nephrologists and two academic pharmacists. The Baker Able Leaflet Design has been applied to develop the layout and design of the P-PILs. Quasi-experimental pre- and post-test design without control group was conducted on 81 HD patients for user-testing of P-PILs. The mean Baker Able Leaflet Design assessment score for English version of the leaflet was 28, and 26 for Kannada version. The overall user-testing knowledge assessment mean scores were observed to have significantly improved from 44.25 to 69.62 with p value <0.001. The overall user opinion of content and legibility of the leaflets was good. Pictogram-based patient information leaflets can be considered an effective educational tool for HD patients.
Noori, Muhammad Yahya; AJi, Zaheer; Khan, Ghazala; Sharafat, Shaheen; Masroor, Muhammad
2015-01-01
Mycobacterial culture is considered as the gold standard for TB diagnosis. It is performed on egg-based media using commercially available eggs to grow Mycobacteria from clinical samples. These eggs are known to contain high concentration of antibiotics, including fluoroquinolones, given to chicken to prevent early mortality. This study was performed to compare Mycobacterial growth on media prepared from commercial and antibiotic free household eggs. Sputum samples from negative (No bacilli in 100 oil immersion field), scanty (1-9 AFB in 100 fields), 1+ (10-99 bacilli per field), 2+ (1-10 bacilli per field) and 3+ (>10 bacilli per field) were inoculated dually on Ogawa medium prepared from commercial and household eggs. Tubes were inspected every fourth day for the appearance of colonies till 60 days. Data tabulations and statistical analysis (F test for variation and unpaired Student's t test) were performed on Microsoft Excel. One microscopically negative sample showed growth on media prepared from household eggs, while all were negative on that prepared from commercial eggs. There were significant differences in time to culture positivity for samples graded 1+ (p = 0.02), 2+ (p = 0.002) and 3+ (p = 0.0003). Commercial eggs containing antibiotics can be a source of false negativity in cultures especially in microscopically negative samples. This can be of special concern in HIV patients who have high smear negativity. It is therefore important to either develop provision of antibiotic free eggs for media preparation or to develop and validate other laboratory investigations for smear negative TB patients.
Investigation of polyvinylchloride and cellulose acetate blend membranes for desalination
NASA Astrophysics Data System (ADS)
El-Gendi, Ayman; Abdallah, Heba; Amin, Ashraf; Amin, Shereen Kamel
2017-10-01
The pollution of water resources, severe climate changes, rapid population growth, increasing agricultural demands, and rapid industrialization insist the development of innovative technologies for generating potable water. Polyvinylchloride/cellulose acetate (PVC/CA) membranes were prepared using phase inversion technique for seawater reverse osmosis (SWRO). The membrane performance was investigated using Red Sea water (El-Ein El-Sokhna-Egypt). The membrane performance indicated that the prepared membranes were endowed to work under high pressure; increasing in feeding operating pressure led to increase permeate flux and rejection. Increasing feed operating pressure from zero to 40 bar led to increase in the salt rejection percent. Salt rejection percent reached to 99.99% at low feed concentration 5120 ppm and 99.95% for Red Sea water (38,528 ppm). The prepared membranes were characterized using scanning electron microscopy (SEM), Fourier transform infrared (FTIR) spectrophotometry, and mechanical properties. SEM, FTIR and mechanical results were used to distinguish the best membrane for desalination. According to characterization results, one prepared membrane was selected to run performance test in desalination testing unit. The membrane (M3) showed excellent performance and stability under different operating conditions and during the durability test for 36 days.
Public stated preferences and predicted uptake for genome-based colorectal cancer screening
2014-01-01
Background Emerging developments in nanomedicine allow the development of genome-based technologies for non-invasive and individualised screening for diseases such as colorectal cancer. The main objective of this study was to measure user preferences for colorectal cancer screening using a nanopill. Methods A discrete choice experiment was used to estimate the preferences for five competing diagnostic techniques including the nanopill and iFOBT. Alternative screening scenarios were described using five attributes namely: preparation involved, sensitivity, specificity, complication rate and testing frequency. Fourteen random and two fixed choice tasks, each consisting of three alternatives, were offered to 2225 individuals. Data were analysed using the McFadden conditional logit model. Results Thirteen hundred and fifty-six respondents completed the questionnaire. The most important attributes (and preferred levels) were the screening technique (nanopill), sensitivity (100%) and preparation (no preparation). Stated screening uptake for the nanopill was 79%, compared to 76% for iFOBT. In the case of screening with the nanopill, the percentage of people preferring not to be screened would be reduced from 19.2% (iFOBT) to 16.7%. Conclusions Although the expected benefits of nanotechnology based colorectal cancer screening are improved screening uptake, assuming more accurate test results and less preparation involved, the relative preference of the nanopill is only slightly higher than the iFOBT. Estimating user preferences during the development of diagnostic technologies could be used to identify relative performance, including perceived benefits and harms compared to competitors allowing for significant changes to be made throughout the process of development. PMID:24642027
40 CFR 1066.420 - Test preparation.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 33 2014-07-01 2014-07-01 false Test preparation. 1066.420 Section... VEHICLE-TESTING PROCEDURES Preparing Vehicles and Running an Exhaust Emission Test § 1066.420 Test... before the test that ambient conditions are within the tolerances specified in this paragraph (c). For...
Design and implementation of a vegetarian food system for a closed chamber test.
Kloeris, V; Vodovotz, Y; Bye, L; Stiller, C Q; Lane, E
1998-01-01
The National Aeronautics and Space Administration (NASA) is conducting a series of closed chamber environmental tests, called the Lunar Mars Life Support Test Project (LMLSTP), which is designed to provide data for the development of surface habitats for the Moon and Mars. These surface habitats will be closed loop environmental systems that will recycle air and water and will grow crops to provide food for crew members. In conjunction with these tests, the Food Systems Engineering Facility at the Johnson Space Center (JSC) tested a 10-day vegetarian menu based on items that can be made from the projected crop list for these habitats. The planned menu met most of the nutritional requirements of the four crew members and was found highly acceptable. Automation of the food preparation and processing equipment was strongly recommended because the preparation time was judged excessive. The waste generated was largely due to leftovers.
A Flight Dynamics Perspective of the Orion Pad Abort One Flight Test
NASA Technical Reports Server (NTRS)
Idicula, Jinu; Williams-Hayes, Peggy S.; Stillwater, Ryan; Yates, Max
2009-01-01
The Orion Crew Exploration Vehicle is America s next generation of human rated spacecraft. The Orion Launch Abort System will take the astronauts away from the exploration vehicle in the event of an aborted launch. The pad abort mode of the Launch Abort System will be flight-tested in 2009 from the White Sands Missile Range in New Mexico. This paper examines some of the efforts currently underway at the NASA Dryden Flight Research Center by the Controls & Dynamics group in preparation for the flight test. The concept of operation for the pad abort flight is presented along with an overview of the guidance, control and navigation systems. Preparations for the flight test, such as hardware testing and development of the real-time displays, are examined. The results from the validation and verification efforts for the aerodynamic and atmospheric models are shown along with Monte Carlo analysis results.
NASA Technical Reports Server (NTRS)
Murri, Daniel G.; Shah, Gautam H.; Dicarlo, Daniel J.
1994-01-01
As part of the NASA High-Angle-of-Attack Technology Program (HATP), flight tests are currently being conducted with a multi-axis thrust vectoring system applied to the NASA F-18 High Alpha Research Vehicle (HARV). A follow-on series of flight tests with the NASA F-18 HARV will be focusing on the application of actuated forebody strake controls. These controls are designed to provide increased levels of yaw control at high angles of attack where conventional aerodynamic controls become ineffective. The series of flight tests are collectively referred to as the Actuated Nose Strakes for Enhanced Rolling (ANSER) Flight Experiment. The development of actuated forebody strake controls for the F-18 HARV is discussed and a summary of the ground tests conducted in support of the flight experiment is provided. A summary of the preparations for the flight tests is also provided.
NASA Technical Reports Server (NTRS)
Zachary, A. T.; Csomor, A.; Tignac, L. L.
1973-01-01
Small, high-performance LO2 and LH2 turbopump assembly configurations were selected, detail designs were prepared and two of each unit were fabricated with each unit consisting of pump, turbine gas generator, and appropriate controls. Following fabrication, development testing was conducted on each type to demonstrate performance, durability, transient characteristics, and heat transfer under simulated altitude conditions. Following successful completion of development effort, the two LO2 turbopump units and one LH2 turbopump unit were acceptance tested as specified. Inspection of the units following development testing revealed no deleterious effects of testing. The test results of LO2 turbopump assembly testing correlated well with predicted performance while the LH2 turbopump test results, though generally consistent with predicted values, did show lower than anticipated developed head at the design point and in the high flow range of operation.
Phase 2 STS new user development program. Volume 1: Executive summary
NASA Technical Reports Server (NTRS)
Mcdowell, J. R.
1976-01-01
A methodology for developing new users for STS other than NASA and DoD, thereby maximizing the use of the STS system was developed. The approach to user development, reflected in the implementation plan, and attendant informational material to be used were evaluated by conducting a series of test cases with selected user organizations. These test case organizations were, in effect, used as consultants to evaluate the effectiveness, the needs, the completeness, and the adequacy of the user development approach and informational material. The selection of the test cases provided a variety of potential STS users covering industry, other government agencies, and the educational sector. The test cases covered various use areas and provided a mix of user organization types. A summary of the actual test cases conducted is given. The conduct of the test cases verified the general approach of the implementation plan, the validity of the user development strategy prepared for each test case organization and the effectiveness of the STS basic and user customized informational material.
1993-01-01
demonstrate improved Pd and Pfa with advanced algorithms, prepare final drop test demonstration. Potential Commercial Market: LADAR profiling and sensing...Field Refrigeration (CRFR) CATEGORY: Exploratory Development OBJECTIVE: To develop a nonpowered (nonelectric) closed-cycle solid-gas sorption
Preparation and preclinical evaluation of 68Ga-DOTA-amlodipine for L-type calcium channel imaging.
Firuzyar, Tahereh; Jalilian, Amir Reza; Aboudzadeh, Mohammad Reza; Sadeghpour, Hossein; Shafiee-Ardestani, Mahdi; Khalaj, Ali
2016-01-01
In order to develop a possible tracer for L-type calcium channel imaging, we here report the development of a Ga-68 amlodipine derivative for possible PET imaging. Amlodipine DOTA conjugate was synthesized, characterized and went through calcium channel blockade, toxicity, apoptosis/necrosis tests. [ 68 Ga] DOTA AMLO was prepared at optimized conditions followed by stability tests, partition coefficient determination and biodistribution studies using tissue counting and co incidence imaging up to 2 h. [ 68 Ga] DOTA AMLO was prepared at pH 4-5 in 7-10 min at 95°C in high radiochemical purity (>99%, radio thin layer chromatography; specific activity: 1.9-2.1 GBq/mmol) and was stable up to 4 h with a log P of -0.94. Calcium channel rich tissues including myocardium, and tissues with smooth muscle cells such as colon, intestine, and lungs demonstrated significant uptake. Co incidence images supported the biodistribution data up to 2 h. The complex can be a candidate for further positron emission tomography imaging for L type calcium channels.
Support of ASTP/KOSMOS fundulus embryo development experiment
NASA Technical Reports Server (NTRS)
Fuller, P. M.; Keefe, J. R.
1977-01-01
Results from the Kosmos Biosatellite 782 flight are presented. Experiments with fish hatchlings are discussed along with postflight observation and testing. The preparation of fertilized eggs for the experiments is described.
Basics of Sterile Compounding: Particulate Matter.
Akers, Michael J
2017-01-01
This article focuses on the requirements for particulate matter in sterile products. Topics include particles and quality, particulate matter standards (large- and small-volume injectables), development of the small-volume injectable test, electronic (light obscuration) and microscope testing, and special requirements for particulate matter in biopharmaceutical preparations. Copyright© by International Journal of Pharmaceutical Compounding, Inc.
Field Testing Vocational Education Metric Modules. Final Report.
ERIC Educational Resources Information Center
Oldsen, Carl F.
A project was conducted for the following purposes: (1) to develop a workshop training package to prepare vocational education teachers to use vocational subject-specific modules; (2) to train those teachers to use the workshop package; (3) to conduct field tests of the metric modules with experimental and control groups; (4) to analyze, describe,…
Yang, Ming; Yang, Yuan-Zhen; Wang, Ya-Qi; Wu, Zhen-Feng; Wang, Xue-Cheng; Luo, Jing
2017-03-01
Product quality relies on not only testing methods,but also the design and development, production control and product manufacturing all aspects of logistics management. Quality comes from the process control level.Therefore, it is very important to accurately identify the factors that may induce quality risk in the production process and quality control measures correspondingly.This article systematically analyzes the source of the quality risk of all aspects of the production process in traditional Chinese medicine preparation. Discussing ways and methods of quality risk identification of traditional Chinese medicine preparation and providing references for perfecting the whole process quality management of traditional Chinese medicine preparation. Copyright© by the Chinese Pharmaceutical Association.
Long-term high-level waste technology. Composite report
NASA Astrophysics Data System (ADS)
Cornman, W. R.
1981-12-01
Research and development studies on the immobilization of high-level wastes from the chemical reprocessing of nuclear reactor fuels are summarized. The reports are grouped under the following tasks: (1) program management and support; (2) waste preparation; (3) waste fixation; and (4) final handling. Some of the highlights are: leaching properties were obtained for titanate and tailored ceramic materials being developed at ICPP to immobilize zirconia calcine; comparative leach tests, hot-cell tests, and process evaluations were conducted of waste form alternatives to borosilicate glass for the immobilization of SRP high-level wastes, experiments were run at ANL to qualify neutron activation analysis and radioactive tracers for measuring leach rates from simulated waste glasses; comparative leach test samples of SYNROC D were prepared, characterized, and tested at LLNL; encapsulation of glass marbles with lead or lead alloys was demonstrated on an engineering scale at PNL; a canister for reference Commercial HLW was designed at PNL; a study of the optimization of salt-crete was completed at SRL; a risk assessment showed that an investment for tornado dampers in the interim storage building of the DWPF is unjustified.
Development of satellite borne nickel hydrogen battery experiment equipment for ETS-6
NASA Astrophysics Data System (ADS)
Kuwashima, Saburou; Kamimori, Norimitsu; Kusawake, Hiroaki; Takahashi, Kazumichi
1992-08-01
An overview of the support rendered for the Engineering Test Satellite-6 (ETS-6) system integration test and protoflight test by the ETS-6 borne experimental nickel hydrogen battery development part is presented. Articles in the ETS-6 specifications and procedures related to the experimental battery were prepared or supported in preparation because of the battery's special characteristics such as its automatic control dependency on the bus voltage, thermal sensitivity equivalent to that of other batteries and so forth. System tests were witnessed and the acquired data were evaluated. Charging characteristics from 0 V were verified at trickle charging rate, using a flight scale model of Nickel Hydrogen (Ni-H2) Battery (NHB) after long term storage and an engineering model of the Ni-H2 Battery Controller (NHC). Requests for approval were submitted to the related self governing bodies in accordance with the Explosives Control Law when NHB's were charged and discharged. Installation and calibration data acquisition of the inner pressure sensors for the Ni-H2 battery cells for the flight model NHB were conducted and the battery assembly was started.
ACT Test Preparation Course and Its Impact on Students' College- and Career-Readiness
ERIC Educational Resources Information Center
Parrott, Timothy Nolan
2012-01-01
This study examined the effectiveness of an ACT intervention course developed for high school juniors at Anderson County High School during the 2011-2012 school year. This study compared the ACT composite test scores of the treatment group to the ACT composite test scores of the control group by using their PLAN scores as a baseline, to determine…
Photoallergic contact dermatitis to oxybenzone.
Collins, P; Ferguson, J
1994-07-01
A 21-year-old woman developed an erythematous papulovesicular eruption of photo-exposed sites, following the use of an oxybenzone-containing sunscreen. Patch testing, photopatch testing, phototesting, and histology produced findings strongly suggestive of oxybenzone photoallergy. Photopatch testing with a monochromator source showed abnormal UVA responses, with evidence of immediate urticaria, and delayed-onset dermatitis. Sun-barrier use is associated with a risk of the development of contact or photocontact allergic reactions. The benzophenones are frequently used in high-protection factor sun-barrier preparations, and appear to have a particular ability to induce such responses.
Development of molecular tests for the detection of ILAR and latent viruses in fruit trees.
Roussel, S; Kummert, J; Dutrecq, O; Lepoivre, P; Jijakli, M H
2004-01-01
The detection throughout the year of latent and ILAR viruses in fruit tress by classical serological tests appear to be unreliable. We have developed RT-PCR tests for a reliable detection of latent and ILAR viruses in fruit trees. These assays were then simplified to allow the direct use of crude plant extracts instead of total RNA preparations, and the analyses of pooled samples. In this way, such RT-PCR protocols are suitable for a routine diagnosis of latent and ILAR viruses in fruit tree certification.
Pilot-scale treatability test plan for the 200-BP-5 operable unit
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
This document presents the treatability test plan for pilot-scale pump and treat testing at the 200-BP-5 Operable Unit. This treatability test plan has been prepared in response to an agreement between the U.S. Department of Energy (DOE), the U.S. Environmental Protection Agency (EPA), and the State of Washington Department of Ecology (Ecology), as documented in Hanford Federal Facility Agreement and Consent Order (Tri-Party Agreement, Ecology et al. 1989a) Change Control Form M-13-93-03 (Ecology et al. 1994) and a recent 200 NPL Agreement Change Control Form (Appendix A). The agreement also requires that, following completion of the activities described in thismore » test plan, a 200-BP-5 Operable Unit Interim Remedial Measure (IRM) Proposed Plan be developed for use in preparing an Interim Action Record of Decision (ROD). The IRM Proposed Plan will be supported by the results of this treatability test plan, as well as by other 200-BP-5 Operable Unit activities (e.g., development of a qualitative risk assessment). Once issued, the Interim Action ROD will specify the interim action(s) for groundwater contamination at the 200-BP-5 Operable Unit. The treatability test approach is to conduct a pilot-scale pump and treat test for each of the two contaminant plumes associated with the 200-BP-5 Operable Unit. Primary contaminants of concern are {sup 99}Tc and {sup 60}Co for underwater affected by past discharges to the 216-BY Cribs, and {sup 90}Sr, {sup 239/240}Pu, and Cs for groundwater affected by past discharges to the 216-B-5 Reverse Well. The purpose of the pilot-scale treatability testing presented in this testplan is to provide the data basis for preparing an IRM Proposed Plan. To achieve this objective, treatability testing must: Assess the performance of groundwater pumping with respect to the ability to extract a significant amount of the primary contaminant mass present in the two contaminant plumes.« less
A Standard Method To Inactivate Bacillus anthracis Spores to Sterility via Gamma Irradiation
Cote, Christopher K.; Buhr, Tony; Bernhards, Casey B.; Bohmke, Matthew D.; Calm, Alena M.; Esteban-Trexler, Josephine S.; Hunter, Melissa; Katoski, Sarah E.; Kennihan, Neil; Klimko, Christopher P.; Miller, Jeremy A.; Minter, Zachary A.; Pfarr, Jerry W.; Prugh, Amber M.; Quirk, Avery V.; Rivers, Bryan A.; Shea, April A.; Shoe, Jennifer L.; Sickler, Todd M.; Young, Alice A.; Fetterer, David P.; Welkos, Susan L.; McPherson, Derrell; Fountain, Augustus W.
2018-01-01
ABSTRACT In 2015, a laboratory of the United States Department of Defense (DoD) inadvertently shipped preparations of gamma-irradiated spores of Bacillus anthracis that contained live spores. In response, a systematic evidence-based method for preparing, concentrating, irradiating, and verifying the inactivation of spore materials was developed. We demonstrate the consistency of spore preparations across multiple biological replicates and show that two different DoD institutions independently obtained comparable dose-inactivation curves for a monodisperse suspension of B. anthracis spores containing 3 × 1010 CFU. Spore preparations from three different institutions and three strain backgrounds yielded similar decimal reduction (D10) values and irradiation doses required to ensure sterility (DSAL) to the point at which the probability of detecting a viable spore is 10−6. Furthermore, spores of a genetically tagged strain of B. anthracis strain Sterne were used to show that high densities of dead spores suppress the recovery of viable spores. Together, we present an integrated method for preparing, irradiating, and verifying the inactivation of spores of B. anthracis for use as standard reagents for testing and evaluating detection and diagnostic devices and techniques. IMPORTANCE The inadvertent shipment by a U.S. Department of Defense (DoD) laboratory of live Bacillus anthracis (anthrax) spores to U.S. and international destinations revealed the need to standardize inactivation methods for materials derived from biological select agents and toxins (BSAT) and for the development of evidence-based methods to prevent the recurrence of such an event. Following a retrospective analysis of the procedures previously employed to generate inactivated B. anthracis spores, a study was commissioned by the DoD to provide data required to support the production of inactivated spores for the biodefense community. The results of this work are presented in this publication, which details the method by which spores can be prepared, irradiated, and tested, such that the chance of finding residual living spores in any given preparation is 1/1,000,000. These irradiated spores are used to test equipment and methods for the detection of agents of biological warfare and bioterrorism. PMID:29654186
Stier, R; Schultz-Brauns, B; Riedesser, P; Zeisel, H J
1983-01-01
Individual observations lead to the realisation that during endoscopy children may develop such a degree of seemingly unexplainable anxiety that the performance of the examination is considerably prejudiced. We therefore examined 39 children systematically, evaluating them according to fearsome products of their imagination on the one hand and real or warranted anxiety on the other. Adjusted to age the children were tested using drawings, projectional tests and role-playing in addition to interviewing, sometimes of their parents as well. The most prominent expressions of anxiety in conjunction with endoscopy were fear of suffocation; fear of damage to internal organs and, in girls, fear of lesions to a "baby inside". In adolescents problems with prudery became evident. On the basis of our experience we developed a systematic model of psychological preparation for endoscopic examinations.
Orion's Neutral Buoyancy Lab (NBL) Activities
2016-09-21
Tim Goddard, center, NASA Open Water Recovery Operations director, briefs U.S. Navy divers, Air Force pararescuemen and Coast Guard rescue swimmers during training in the Neutral Buoyancy Laboratory at NASA’s Johnson Space Center in Houston. The group will practice Orion underway recovery techniques using a test version of the Orion spacecraft. Training will help the team prepare for Underway Recovery Test 5 for Exploration Mission 1 aboard the USS San Diego in the Pacific Ocean off the coast of California in October. The Ground Systems Development and Operations Program, along with the U.S. Navy and Lockheed Martin, are preparing the recovery team, hardware and operations to support EM-1 recovery.
Orion's Neutral Buoyancy Lab (NBL) Activities
2016-09-21
U.S. Navy divers, Air Force pararescuemen and Coast Guard rescue swimmers practice Orion recovery techniques at the Neutral Buoyancy Laboratory (NBL) at the agency’s Johnson Space Center in Houston. The recovery team is practicing underway recovery techniques using a test version of the Orion spacecraft. Training will help the team prepare for Underway Recovery Test 5 for Exploration Mission 1 aboard the USS San Diego in the Pacific Ocean off the coast of California in October. The Ground Systems Development and Operations Program, along with the U.S. Navy and Lockheed Martin, are preparing the recovery team, hardware and operations to support EM-1 recovery.
Development of a CO 2 Chemical Sensor for Downhole CO 2 Monitoring in Carbon Sequestration
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Ning
Geologic storage of carbon dioxide (CO 2) has been proposed as a viable means for reducing anthropogenic CO 2 emissions. The means for geological sequestration of CO 2 is injection of supercritical CO 2 underground, which requires the CO 2 to remain either supercritical, or in solution in the water/brine present in the underground formation. However, there are aspects of geologic sequestration that need further study, particularly in regards to safety. To date, none of the geologic sequestration locations have been tested for storage integrity under the changing stress conditions that apply to the sequestration of very large amounts ofmore » CO 2. Establishing environmental safety and addressing public concerns require widespread monitoring of the process in the deep subsurface. In addition, studies of subsurface carbon sequestration such as flow simulations, models of underground reactions and transports require a comprehensive monitoring process to accurately characterize and understand the storage process. Real-time information about underground CO 2 movement and concentration change is highly helpful for: (1) better understanding the uncertainties present in CO 2 geologic storage; (2) improvement of simulation models; and (3) evaluation of the feasibility of geologic CO 2 storage. Current methods to monitor underground CO 2 storage include seismic, geoelectric, isotope and tracer methods, and fluid sampling analysis. However, these methods commonly resulted low resolution, high cost, and the inability to monitor continuously over the long time scales of the CO 2 storage process. A preferred way of monitoring in-situ underground CO 2 migration is to continuous measure CO 2 concentration change in brine during the carbon storage process. An approach to obtain the real time information on CO 2 concentration change in formation solution is highly demanded in carbon storage to understand the CO 2 migration subsurface and to answer the public safety problem. The objective of the study is to develop a downhole CO 2 sensor that can in-situ, continuously monitor CO 2 concentration change in deep saline. The sensor is a Severinghaus-type CO 2 sensor with small size, which renders it can be embedded in monitoring well casing or integrated with pressure/temperature transducers, enabling the development of “smart” wells. The studies included: (1) prepare and characterize metal-oxide electrodes. Test the electrodes response to pH change. Investigate different ions and brine concentration effects on the electrode’s performance. Study the stability of the electrode in brine solution; (2) fabricate a downhole CO 2 sensor with the metal-oxide electrodes prepared in the laboratory. Test the performance of the CO 2 sensor in brine solutions. Study high pressure effects on the performance of the sensor; (3) design and conduct CO 2/brine coreflooding experiments with the CO2 sensor. Monitor CO 2 movement along the core and test the performance of the sensor in coreflooding tests. Develop a data acquisition system that can digitize the sensor’s output voltage. Our completed research has resulted in deep understanding of downhole CO 2 sensor development and CO 2 monitoring in CO 2 storage process. The developed downhole CO 2 sensor included a metal-oxide electrode, a gas-permeable membrane, a porous steel cup, and a bicarbonate-based internal electrolyte solution. Iridium oxide-based electrode was prepared and used for preparation the CO 2 sensor. The prepared iridium oxide-based electrode displayed a linearly response to pH change. Different factors such as different ions and ions concentration, temperature, and pressure effects on the electrode performance on pH response were investigated. The results indicated that the electrode exhibited a good performance even in high salt concentration of produced water. To improve the electrode performance under high pressure, IrO 2 nanoparticles with the particle size in the range of 1-2 nm were prepared and electrodeposited on stainless steel substrate by cyclic voltammetry. It was observed that the thin film of iridium oxide was formed on the substrate surface and such iridium oxide-based electrode displayed excellent performance under high pressure for longer term. A downhole CO 2 sensor with the iridium oxide-based electrode was prepared. The working principle of the CO 2 sensor is based on the measurement of the pH change of the internal electrolyte solution caused by the hydrolysis of CO 2 and then determination of the CO 2 concentration in water. The prepared downhole CO 2 sensor had the size of diameter of 0.7 in. and length of 1.5 in. The sensor was tested under the pressures of 500 psi, 2,000 psi, and 3,000 psi. A linear correlation was observed between the sensor potential change and dissolved CO 2 concentration in water. The response time of the CO 2 sensor was in the range of 60-100 minutes. Further tests indicated that the CO 2 sensor exhibited good reproducibility under high pressure. A CO 2/brine coreflooding system was constructed to simulate the real-world CO 2 storage process. The prepared downhole CO 2 sensor was loaded in the system to monitor CO 2 movement during CO 2/brine coreflooding test. The results indicated that the sensor could detect CO 2 movement in the tests. Further studies showed that the sensor could be recovered by brine flooding after CO 2/brine flushed the core. The results of the coreflooding tests demonstrated that the sensor had potential application for CO 2 monitoring in carbon sequestration. A data acquisition system for the downhoe CO 2 sensor was developed and coded. The system converted the sensor output signal into digital data and transported the data from downhole to wellhead surface. The data acquisition system was tested and evaluated in the laboratory with the prepared sensor for data collection.« less
Performance Evaluation Test of the Rapid Area Preparation Tool (RAPTOR)
2008-12-01
the standard SETCO tires. A blast test of the new SETCO tire is scheduled for the spring of...Washington, DC 20301-2500 Performance Evaluation Test of the Rapid Area Preparation Tool (RAPTOR) December 2008 Prepared ...2008 to 00-00-2008 4. TITLE AND SUBTITLE Performance Evaluation Test of the Rapid Area Preparation Tool (RAPTOR) 5a. CONTRACT NUMBER 5b.
ERIC Educational Resources Information Center
Alon, Sigal
2010-01-01
Claudia Buchmann, Dennis Condron and Vincent Roscigno's study, titled "Shadow Education, American Style: Test Preparation, the SAT and College Enrollment," demonstrates that vigorous use of expensive test preparation tools, such as private classes and tutors, significantly boosts scores on standardized exams such as the SAT or ACT. This…
Development of Generalizable Educational Programs in Laser/Electro-Optics Technology: Final Report.
ERIC Educational Resources Information Center
Hull, Daniel M.
The purpose of the Laser/Electro-Optics Technology (LEOT) Project was to establish a pilot educational program, develop a flexible curriculum, prepare and test instructional materials, transport the curriculum and instructional materials into other educational institutions by establishing relevant LEOT programs wherever they are needed, and to…
Effluent Monitoring Procedures: Nutrients. Staff Guide.
ERIC Educational Resources Information Center
Environmental Protection Agency, Washington, DC. Office of Water Programs.
This is one of several short-term courses developed to assist in the training of waste water treatment plant operational personnel in the tests, measurements, and report preparation required for compliance with their NPDES Permits. This Staff Guide provides step-by-step guidelines on course planning, development and implementation involving…
Prepare for More Realistic Test Results
ERIC Educational Resources Information Center
Larson, Matthew R.; Leinwand, Steven
2013-01-01
Educators in forty-five states and the District of Columbia are hard at work interpreting and implementing the Common Core State Standards for Mathematics (CCSSM) (CCSSI 2010). This work typically involves teacher participation in professional development activities focused on developing an understanding of the content standards as well as the…
Research Report for the Organizing for Diversity Project.
ERIC Educational Resources Information Center
Betsinger, Alicia M.; Garcia, Shernaz B.; Guerra, Patricia L.
This report describes the Organizing for Diversity Project, which generated professional development modules to prepare teachers to work more effectively with diverse students. Prototype modules were developed in collaboration with teacher volunteers, then field tested. The final 11 modules, which included 33 hours of training, were designed for…
Effluent Monitoring Procedures: Metals Analyses. Staff Guide.
ERIC Educational Resources Information Center
Environmental Protection Agency, Washington, DC. Office of Water Programs.
This is one of several short-term courses developed to assist in the training of waste water treatment plant operational personnel in the tests, measurements, and report preparation required for compliance with their NPDES Permits. The Staff Guide provides step-by-step information on course planning, development, and implementation involving…
Recent Additions to the General College Career Development Program Offerings.
ERIC Educational Resources Information Center
Hixson, Bruce, Ed.
1981-01-01
Recent additions to the career development offerings at the University of Minnesota's General College are described. The aviation training program, which is described by Thomas Brothen, is designed to prepare students for licensure testing through the Federal Aviation Administration. Background information on aviation training at the University of…
Finite element simulation of cutting grey iron HT250 by self-prepared Si3N4 ceramic insert
NASA Astrophysics Data System (ADS)
Wang, Bo; Wang, Li; Zhang, Enguang
2017-04-01
The finite element method has been able to simulate and solve practical machining problems, achieve the required accuracy and the highly reliability. In this paper, the simulation models based on the material properties of the self-prepared Si3N4 insert and HT250 were created. Using these models, the results of cutting force, cutting temperature and tool wear rate were obtained, and tool wear mode was predicted after cutting simulation. These approaches may develop as the new method for testing new cutting-tool materials, shortening development cycle and reducing the cost.
Lessons learned in preparing method 29 filters for compliance testing audits.
Martz, R F; McCartney, J E; Bursey, J T; Riley, C E
2000-01-01
Companies conducting compliance testing are required to analyze audit samples at the time they collect and analyze the stack samples if audit samples are available. Eastern Research Group (ERG) provides technical support to the EPA's Emission Measurements Center's Stationary Source Audit Program (SSAP) for developing, preparing, and distributing performance evaluation samples and audit materials. These audit samples are requested via the regulatory Agency and include spiked audit materials for EPA Method 29-Metals Emissions from Stationary Sources, as well as other methods. To provide appropriate audit materials to federal, state, tribal, and local governments, as well as agencies performing environmental activities and conducting emission compliance tests, ERG has recently performed testing of blank filter materials and preparation of spiked filters for EPA Method 29. For sampling stationary sources using an EPA Method 29 sampling train, the use of filters without organic binders containing less than 1.3 microg/in.2 of each of the metals to be measured is required. Risk Assessment testing imposes even stricter requirements for clean filter background levels. Three vendor sources of quartz fiber filters were evaluated for background contamination to ensure that audit samples would be prepared using filters with the lowest metal background levels. A procedure was developed to test new filters, and a cleaning procedure was evaluated to see if a greater level of cleanliness could be achieved using an acid rinse with new filters. Background levels for filters supplied by different vendors and within lots of filters from the same vendor showed a wide variation, confirmed through contact with several analytical laboratories that frequently perform EPA Method 29 analyses. It has been necessary to repeat more than one compliance test because of suspect metals background contamination levels. An acid cleaning step produced improvement in contamination level, but the difference was not significant for most of the Method 29 target metals. As a result of our studies, we conclude: Filters for Method 29 testing should be purchased in lots as large as possible. Testing firms should pre-screen new boxes and/or new lots of filters used for Method 29 testing. Random analysis of three filters (top, middle, bottom of the box) from a new box of vendor filters before allowing them to be used in field tests is a prudent approach. A box of filters from a given vendor should be screened, and filters from this screened box should be used both for testing and as field blanks in each test scenario to provide the level of quality assurance required for stationary source testing.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-08
...Pursuant to section 102(2)(c) of the National Environmental Policy Act of 1969, as implemented by the Council on Environmental Quality Regulations (40 Code of Federal Regulations parts 1500-1508), and Executive Order 12114, the Department of the Navy (DoN) announces its intent to prepare an Environmental Impact Statement (EIS)/Overseas Environmental Impact Statement (OEIS) to evaluate the potential environmental effects associated with maintaining military readiness training and research, development, testing, and evaluation (hereafter referred to as ``training and testing'') activities conducted in the Mariana Islands Training and Testing (MITT) EIS/OEIS Study Area. The MITT Study Area includes the existing Mariana Islands Range Complex (MIRC), additional areas on the high seas, and a general transit corridor between Hawaii to MITT where training and testing activities may occur. The MIRC is the only major Navy range complex in the Study Area. The DoN is preparing this EIS/OEIS to renew current regulatory permits and authorizations, address current training and testing not covered under existing permits and authorizations, and to obtain those permits and authorizations necessary to support force structure changes and emerging and future training and testing requirements including those associated with new platforms and weapons systems within the MITT Study Area, starting in 2015, thereby ensuring critical Department of Defense (DoD) requirements are met. The DoN will invite the National Marine Fisheries Service, United States (U.S.) Fish and Wildlife Service (Pacific Islands Fish and Wildlife Office), and U.S. Air Force, to be cooperating agencies in preparation of the EIS/OEIS.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Maharrey, Sean P.; Highley, Aaron M.; Behrens, Richard, Jr.
2007-12-01
The objective of this short-term LDRD project was to acquire the tools needed to use our chemical imaging precision mass analyzer (ChIPMA) instrument to analyze tissue samples. This effort was an outgrowth of discussions with oncologists on the need to find the cellular origin of signals in mass spectra of serum samples, which provide biomarkers for ovarian cancer. The ultimate goal would be to collect chemical images of biopsy samples allowing the chemical images of diseased and nondiseased sections of a sample to be compared. The equipment needed to prepare tissue samples have been acquired and built. This equipment includesmore » an cyro-ultramicrotome for preparing thin sections of samples and a coating unit. The coating unit uses an electrospray system to deposit small droplets of a UV-photo absorbing compound on the surface of the tissue samples. Both units are operational. The tissue sample must be coated with the organic compound to enable matrix assisted laser desorption/ionization (MALDI) and matrix enhanced secondary ion mass spectrometry (ME-SIMS) measurements with the ChIPMA instrument Initial plans to test the sample preparation using human tissue samples required development of administrative procedures beyond the scope of this LDRD. Hence, it was decided to make two types of measurements: (1) Testing the spatial resolution of ME-SIMS by preparing a substrate coated with a mixture of an organic matrix and a bio standard and etching a defined pattern in the coating using a liquid metal ion beam, and (2) preparing and imaging C. elegans worms. Difficulties arose in sectioning the C. elegans for analysis and funds and time to overcome these difficulties were not available in this project. The facilities are now available for preparing biological samples for analysis with the ChIPMA instrument. Some further investment of time and resources in sample preparation should make this a useful tool for chemical imaging applications.« less
10 CFR 26.93 - Preparing for alcohol testing.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 1 2011-01-01 2011-01-01 false Preparing for alcohol testing. 26.93 Section 26.93 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.93 Preparing for alcohol testing. (a) Immediately before collecting a specimen for alcohol testing, the collector...
10 CFR 26.93 - Preparing for alcohol testing.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 1 2010-01-01 2010-01-01 false Preparing for alcohol testing. 26.93 Section 26.93 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.93 Preparing for alcohol testing. (a) Immediately before collecting a specimen for alcohol testing, the collector...
Training and Human Factors Research in Military Systems. A Final Report
1989-05-01
Combat vehicle Human factors/ identification (CVI), Operational test and evaluatio (Continued) 19. ABSTRACT (Continue on reverse if necessaty and...prepared on the management of CVI for service schools (1985). * A videotape entitled "Training for Combat" was prepared as an update for the CVI and TAATS...media, and the effects of image motion on CVI training performance. Future Developments The ART -Fort Hood TAATS program was terminated in 1987, and
NASA Astrophysics Data System (ADS)
Rohyami, Yuli; Anjani, Rafika Debby; Purwanti, Napthalina Putri
2017-03-01
Virgin coconut oil is an excellent product which has result of oil processing business opportunities in the international market. Standardization of virgin coconut oil necessary to satisfy the requirements industry needs. This research is expected as procedure preparation of reference materials. Preparation of virgin coconut oil by Sacharomycescerevisiaeenzyme. Based on the results of this study concluded that the ratio of Saccharomyces cerevisiae can affect the yield of virgin coconut oil produced. The preparation of virgin coconut oil enzymatically using a variety of mass ratio of 0.001 to 0.006% is obtained yield average of 12.40%. The optimum separation of virgin coconut oil on the use of enzymes with a mass ratio of 0.002%. The average water content at a ratio of 0.002% is 0.04 % with a value of uncertainty is 0.005%. The average iodine number in virgin coconut oil produced is 2.4403 ± 0,1974 grams of iodine per 100 grams of oil and optimum iodine number is obtained from the manufacturing process virgin coconut oil with a ratio of 0.006% Saccharomyces cerevisiae. Sacharomycescerevisiae with a ratio of 0.002% results virgin coconut oil with acid number 0.3068 ± 0.1098%. The peroxide value of virgin coconut oil between 0.0108 ± 0.009 to 0.0114 ± 0015milli-equivalent per kilograms. Organoleptic test results and test chemical parameters can be used as the test data that can be developed in prototype preparation of candidate in-house reference material in the testing standards of quality virgin coconut oil.
Development of a Process for a High Capacity Arc Heater Production of Silicon for Solar Arrays
NASA Technical Reports Server (NTRS)
Reed, W. H.
1979-01-01
A program was established to develop a high temperature silicon production process using existing electric arc heater technology. Silicon tetrachloride and a reductant (sodium) are injected into an arc heated mixture of hydrogen and argon. Under these high temperature conditions, a very rapid reaction is expected to occur and proceed essentially to completion, yielding silicon and gaseous sodium chloride. Techniques for high temperature separation and collection were developed. Included in this report are: test system preparation; testing; injection techniques; kinetics; reaction demonstration; conclusions; and the project status.
Development of a reference material of a single DNA molecule for the quality control of PCR testing.
Mano, Junichi; Hatano, Shuko; Futo, Satoshi; Yoshii, Junji; Nakae, Hiroki; Naito, Shigehiro; Takabatake, Reona; Kitta, Kazumi
2014-09-02
We developed a reference material of a single DNA molecule with a specific nucleotide sequence. The double-strand linear DNA which has PCR target sequences at the both ends was prepared as a reference DNA molecule, and we named the PCR targets on each side as confirmation sequence and standard sequence. The highly diluted solution of the reference molecule was dispensed into 96 wells of a plastic PCR plate to make the average number of molecules in a well below one. Subsequently, the presence or absence of the reference molecule in each well was checked by real-time PCR targeting for the confirmation sequence. After an enzymatic treatment of the reaction mixture in the positive wells for the digestion of PCR products, the resultant solution was used as the reference material of a single DNA molecule with the standard sequence. PCR analyses revealed that the prepared samples included only one reference molecule with high probability. The single-molecule reference material developed in this study will be useful for the absolute evaluation of a detection limit of PCR-based testing methods, the quality control of PCR analyses, performance evaluations of PCR reagents and instruments, and the preparation of an accurate calibration curve for real-time PCR quantitation.
ERIC Educational Resources Information Center
Anderson, Herbert L.
1974-01-01
The final installment of the author's recollections of his work with physicists Enrico Fermi, Leo Szilard and others in developing the first controlled nuclear chain reaction and in preparing the test explosion of the first atomic bomb. (GS)
Test plan for performance testing of the Eaton AC-3 electric vehicle
NASA Astrophysics Data System (ADS)
Crumley, R.; Heiselmann, H. W.
1985-04-01
An alternating current (ac) propulsion system for an electric vehicle was developed and tested. The test bed vehicle is a modified 1981 Mercury Lynx. The test plan was prepared specifically for the third modification to this test bed and identified as the Eaton AC-3. The scope of the testing done on the Eaton AC-3 includes coastdown and dynamometer tests but does not include environmental, on-road, or track testing. Coastdown testing is performed in accordance with SAE J-1263 (SAE Recommended Practice for Road Load Measurement and Dynamometer Simulation Using Coastdown Techniques).
Effectiveness of Multipurpose Unit Early Classroom Intervention Program for 4-5-Year-Old Children
ERIC Educational Resources Information Center
Celebioglu Morkoc, Ozlem; Aktan Acar, Ebru
2014-01-01
This research examined the effectiveness of Multipurpose Unit Early Classroom Intervention Program (MUECIP) prepared for 4-5-year-old (48-60 months) children whose development is at risk because of their families' socioeconomic conditions. The research adopted a preliminary test-final test control group trial model. The research participants were…
Consumer Education: A Conceptual Structure and Planning Guide for Senior High Schools in Wisconsin.
ERIC Educational Resources Information Center
Appleton Public Schools, WI.
Prepared by junior and senior high teachers, the curriculum guide is an interdisciplinary approach by the business education, home economics, and social studies departments to a consumer education course. The initial development of materials was field tested and revised; a second-year field testing of the revised curriculum and a final analysis…
The Effect of Modeling Based Science Education on Critical Thinking
ERIC Educational Resources Information Center
Bati, Kaan; Kaptan, Fitnat
2015-01-01
In this study to what degree the modeling based science education can influence the development of the critical thinking skills of the students was investigated. The research was based on pre-test-post-test quasi-experimental design with control group. The Modeling Based Science Education Program which was prepared with the purpose of exploring…
In situ gas treatment technology demonstration test plan
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thornton, E.C.; Miller, R.D.
1996-02-16
This document defines the objectives and requirements associated with undertaking a field demonstration of an in situ gas treatment appoach to remediation chromate-contaminated soil. The major tasks presented in this plan include the design and development of the surface gas treatment system, performance of permitting activities, and completion of site preparation and field testing activities.
Manager's handbook for software development, revision 1
NASA Technical Reports Server (NTRS)
1990-01-01
Methods and aids for the management of software development projects are presented. The recommendations are based on analyses and experiences of the Software Engineering Laboratory (SEL) with flight dynamics software development. The management aspects of the following subjects are described: organizing the project, producing a development plan, estimating costs, scheduling, staffing, preparing deliverable documents, using management tools, monitoring the project, conducting reviews, auditing, testing, and certifying.
40 CFR 205.57-3 - Test vehicle preparation.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 25 2011-07-01 2011-07-01 false Test vehicle preparation. 205.57-3... PROGRAMS TRANSPORTATION EQUIPMENT NOISE EMISSION CONTROLS Medium and Heavy Trucks § 205.57-3 Test vehicle preparation. (a) Prior to the official test, the test vehicle selected in accordance with § 205-57-2 shall not...
Development of test specimens to obtain the transmission factors to attenuate photons of 0.511 MeV
NASA Astrophysics Data System (ADS)
Costa, J. J. S.; Cardoso, D. D.; Gavazza, S.; Oliveira, C. L.; Morales, R. K.; Amorim, A. S.; Balthar, M. C. V.; Oliveira, L. S. R.
2018-03-01
For designing a shielding, it is necessary, mainly, to determine or have access to the following parameters: transmission factors of the material used and type of radiation to be shielded. Cylindrical test specimens with different thicknesses were developed for experimentally obtaining the material transmission factor for shielding calculation. The cylindrical test specimens were made considering the geometric characteristics of the detector, the ease of production and the energy of 0.511 MeV from the 18F-FDG decay. A type of concrete widely used in Brazil was used in the preparation of the cylindrical test specimens.
Quadrocopter Control Design and Flight Operation
NASA Technical Reports Server (NTRS)
Karwoski, Katherine
2011-01-01
A limiting factor in control system design and analysis for spacecraft is the inability to physically test new algorithms quickly and cheaply. Test flights of space vehicles are costly and take much preparation. As such, EV41 recently acquired a small research quadrocopter that has the ability to be a test bed for new control systems. This project focused on learning how to operate, fly, and maintain the quadrocopter, as well as developing and testing protocols for its use. In parallel to this effort, developing a model in Simulink facilitated the design and analysis of simple control systems for the quadrocopter. Software provided by the manufacturer enabled testing of the Simulink control system on the vehicle.
NASA Technical Reports Server (NTRS)
Kaufman, A.; Olson, B.; Pudick, S.; Wang, C. L.; Werth, J.; Whelan, J. A.
1986-01-01
A 25-cell stack of the 13 inch x 23 inch cell size (about 4kW) remains on test after 8300 hours, using simulated reformate fuel. A similar stack was previously shut down after 7000 hours on load. These tests have been carried out for the purpose of assessing the durability of fuel cell stack components developed through the end of 1983. A 25kW stack containing 175 cells of the same size and utilizing a technology base representative of the 25-cell stacks has been constructed and is undergoing initial testing. A third 4kW stack is being prepared, and this stack will incorporate several new technology features.
Computerized NCLEX-RN and NCLEX-PN preparation programs. Comparative review, 1997.
Riner, M E; Mueller, C; Ihrke, B; Smolen, R A; Wilson, M; Richardson, V; Stone, C; Zwirn, E E
1997-01-01
The computerized test taking market continues to expand to meet the needs of nursing students studying to prepare for the NCLEX-RN and the NCLEX-PN. In addition, currently registered nurses may choose to use these software programs to review clinical knowledge in areas in which they are not currently practicing. This article reviewed software designed for personal use, review books with complete disks, on-site institutional testing and consultation, and school of nursing LANs. The costs of software for personal use is priced reasonably and provides flexibility for students to use as their schedule permits. The cost of institutional licenses is moderate and most programs provide multiple on-site use rights. The marketplace has responded to the computerized NCLEX testing now in place nationally. As new formats are developed and new uses identified, nursing faculty and students can expect to see an expanded use of computerized testing.
2013-12-10
CAPE CANAVERAL, Fla. – Preparations are underway to prepare the Project Morpheus prototype lander for its first free flight test at the north end of the Shuttle Landing Facility at NASA’s Kennedy Space Center in Florida. Testing of the prototype lander was performed at NASA’s Johnson Space Center in Houston in preparation for tethered and free flight testing at Kennedy. Project Morpheus integrates NASA’s automated landing and hazard avoidance technology, or ALHAT, with an engine that runs on liquid oxygen and methane, or green propellants, into a fully-operational lander that could deliver cargo to asteroids and other planetary surfaces. The landing facility will provide the lander with the kind of field necessary for realistic testing, complete with rocks, craters and hazards to avoid. Morpheus’ ALHAT payload allows it to navigate to clear landing sites amidst rocks, craters and other hazards during its descent. Project Morpheus is being managed under the Advanced Exploration Systems, or AES, Division in NASA’s Human Exploration and Operations Mission Directorate. The efforts in AES pioneer new approaches for rapidly developing prototype systems, demonstrating key capabilities and validating operational concepts for future human missions beyond Earth orbit. For more information on Project Morpheus, visit http://morpheuslander.jsc.nasa.gov. Photo credit: NASA/Kim Shiflett
2013-12-17
CAPE CANAVERAL, Fla. -- Preparations are underway to prepare the Project Morpheus prototype lander for a second free flight test at the north end of the Shuttle Landing Facility at NASA’s Kennedy Space Center in Florida. Testing of the prototype lander was performed at NASA’s Johnson Space Center in Houston in preparation for tethered and free flight testing at Kennedy. Project Morpheus integrates NASA’s automated landing and hazard avoidance technology, or ALHAT, with an engine that runs on liquid oxygen and methane, or green propellants, into a fully-operational lander that could deliver cargo to other planetary surfaces. The landing facility will provide the lander with the kind of field necessary for realistic testing, complete with rocks, craters and hazards to avoid. Morpheus’ ALHAT payload allows it to navigate to clear landing sites amidst rocks, craters and other hazards during its descent. Project Morpheus is being managed under the Advanced Exploration Systems, or AES, Division in NASA’s Human Exploration and Operations Mission Directorate. The efforts in AES pioneer new approaches for rapidly developing prototype systems, demonstrating key capabilities and validating operational concepts for future human missions beyond Earth orbit. For more information on Project Morpheus, visit http://morpheuslander.jsc.nasa.gov. Photo credit: NASA/Dimitri Gerondidakis
2013-12-10
CAPE CANAVERAL, Fla. – Preparations are underway to prepare the Project Morpheus prototype lander for its first free flight test at the north end of the Shuttle Landing Facility at NASA’s Kennedy Space Center in Florida. Testing of the prototype lander was performed at NASA’s Johnson Space Center in Houston in preparation for tethered and free flight testing at Kennedy. Project Morpheus integrates NASA’s automated landing and hazard avoidance technology, or ALHAT, with an engine that runs on liquid oxygen and methane, or green propellants, into a fully-operational lander that could deliver cargo to asteroids and other planetary surfaces. The landing facility will provide the lander with the kind of field necessary for realistic testing, complete with rocks, craters and hazards to avoid. Morpheus’ ALHAT payload allows it to navigate to clear landing sites amidst rocks, craters and other hazards during its descent. Project Morpheus is being managed under the Advanced Exploration Systems, or AES, Division in NASA’s Human Exploration and Operations Mission Directorate. The efforts in AES pioneer new approaches for rapidly developing prototype systems, demonstrating key capabilities and validating operational concepts for future human missions beyond Earth orbit. For more information on Project Morpheus, visit http://morpheuslander.jsc.nasa.gov. Photo credit: NASA/Kim Shiflett
2013-12-17
CAPE CANAVERAL, Fla. -- Preparations are underway to prepare the Project Morpheus prototype lander for a second free flight test at the north end of the Shuttle Landing Facility at NASA’s Kennedy Space Center in Florida. Testing of the prototype lander was performed at NASA’s Johnson Space Center in Houston in preparation for tethered and free flight testing at Kennedy. Project Morpheus integrates NASA’s automated landing and hazard avoidance technology, or ALHAT, with an engine that runs on liquid oxygen and methane, or green propellants, into a fully-operational lander that could deliver cargo to other planetary surfaces. The landing facility will provide the lander with the kind of field necessary for realistic testing, complete with rocks, craters and hazards to avoid. Morpheus’ ALHAT payload allows it to navigate to clear landing sites amidst rocks, craters and other hazards during its descent. Project Morpheus is being managed under the Advanced Exploration Systems, or AES, Division in NASA’s Human Exploration and Operations Mission Directorate. The efforts in AES pioneer new approaches for rapidly developing prototype systems, demonstrating key capabilities and validating operational concepts for future human missions beyond Earth orbit. For more information on Project Morpheus, visit http://morpheuslander.jsc.nasa.gov. Photo credit: NASA/Dimitri Gerondidakis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Frame, R.R.; Gala, H.B.
1992-12-31
The objectives of this contract are to develop a technology for the production of active and stable iron Fischer-Tropsch catalysts for use in slurry-phase synthesis reactors and to develop a scaleup procedure for large-scale synthesis of such catalysts for process development and long-term testing in slurry bubble-column reactors. With a feed containing hydrogen and carbon monoxide in the molar ratio of 0.5 to 1.0 to the slurry bubble-column reactor, the catalyst performance target is 88% CO + H{sub 2} conversion at a minimum space velocity of 2.4 NL/hr/gFe. The desired sum of methane and ethane selectivities is no more thanmore » 4%, and the conversion loss per week is not to exceed 1%. Contract Tasks are as follows: 1.0--Catalyst development, 1.1--Technology assessment, 1.2--Precipitated catalyst preparation method development, 1.3--Novel catalyst preparation methods investigation, 1.4--Catalyst pretreatment, 1.5--Catalyst characterization, 2.0--Catalyst testing, 3.0--Catalyst aging studies, and 4.0--Preliminary design and cost estimate of a catalyst synthesis facility. This paper reports progress made on Task 1.« less
Cross-District Collaboration: Curriculum and Professional Development
ERIC Educational Resources Information Center
Short, Deborah J.; Cloud, Nancy; Morris, Patricia; Motta, Julie
2012-01-01
Secondary English as a second language (ESL) curricula that address four levels of ESL proficiency and prepare students for the English language arts (ELA) curricula and state-mandated ELA tests are not common. A curriculum jointly developed by two districts is even rarer. Yet two urban districts in Rhode Island undertook such a curriculum…
Outdoor Biology Instructional Strategies (OBIS): 1972-79. Final Project Report.
ERIC Educational Resources Information Center
Laetsch, W. M.; Knott, Robert C.
Prepared for the National Science Foundation (NSF), this report summarizes the development and work of the Outdoor Biology Instructional Strategies (OBIS) project from 1972 to 1979. One hundred activities for ten- to fifteen-year-olds in community groups (scouts, clubs, camps, churches, etc.) were developed, field tested, revised, and made…
Effluent Monitoring Procedures: Basic Parameters for Municipal Effluents. Staff Guide.
ERIC Educational Resources Information Center
Environmental Protection Agency, Washington, DC. Office of Water Programs.
This is one of several short-term courses developed to assist in the training of waste water treatment plant operational personnel in the tests, measurements, and report preparation required for compliance with their NPDES Permits. This Staff Guide provides step-by-step guidelines on course planning, development and implementation involving…
Composite-Unit Accelerated Life Testing (CUALT) of Sonar Transducers
1979-09-01
Developed and technically defended the Texas Research Institute CUALT plan, Helped prepare sections 5 and 7. Edward Hobaica and Ray Haworth - Developed...le2--Te- TT-Sonar 3R. A. Larmi, E. C. Hobaica , Failure Modes & Effects Analysis for the DT-308’ (now called the DT-605) Hydrophone, EB Div Report No.: U
ERIC Educational Resources Information Center
De La Paz, Susan; Owen, Bonnie; Harris, Karen R.; Graham, Steve
2000-01-01
This article describes implementation of the Self-Regulated Strategy Development (SRSD) approach to help students learn a specific essay writing strategy in preparation for a state writing test. It also reviews the theoretical and research bases for using SRSD to teaching writing strategies. (Contains references.) (DB)
Intercomparison of U.S. Ballast Water Test Facilities
2012-11-01
with many of the requirements of the ETV Protocol, although in some aspects, they employed different approaches and processes . The ETV Protocol calls...and recommendations from the audit process will be reported separately by NSF (in preparation). Both TFs benefited from developing procedures needed...11 4.1.2 Development Process
Whole-Grain Continuing Education for School Foodservice Personnel: Keeping Kids from Falling Short
ERIC Educational Resources Information Center
Roth-Yousey, Lori; Barno, Trina; Caskey, Mary; Asche, Kimberly; Reicks, Marla
2009-01-01
Objective: The purpose of this project was to develop and test whole-grain continuing education for school foodservice personnel. Methods: A continuing education program was developed to address planning, purchasing, preparing, and serving whole-grain food in schools. Participants completed a pre-post questionnaire to assess changes in knowledge,…
Development of a piezoelectric sensor for the detection of methamphetamine.
Romero Guerra, Maria; Chianella, Iva; Piletska, Elena V; Karim, Kal; Turner, Anthony P F; Piletsky, Sergey A
2009-08-01
A computationally designed molecularly imprinted polymer (MIP) specific for methamphetamine was used as a synthetic receptor for the development of a piezoelectric sensor. Several different protocols were tested for the immobilisation of the MIP onto the gold sensor surface. The developed MIP sensor had a detection limit for methamphetamine as low as 1 microg mL(-1). The effect of the addition of poly(vinyl acetate) (PVA) on the pre-polymerisation mixtures, which increases the porosity of the polymer layer, was also studied using an Atomic Force Microscope (AFM). PVA seemed to affect both the porosity and the binding kinetics of the polymers prepared in dimethylformamide (DMF). However, no clear effect on porosity and binding kinetics was observed when polymers were prepared in diglyme. Moreover, PVA did not appear to improve the amplitude of the sensor response. In conclusion, because of its excellent recognition ability in aqueous solutions, the sensor described in this work could be an ideal starting point for the development of a commercial device for fast, on-site or road-side testing of drugs of abuse in body fluids such as saliva.
Rennie, Waverly; Phetsouvanh, Rattanaxay; Lupisan, Socorro; Vanisaveth, Viengsay; Hongvanthong, Bouasy; Phompida, Samlane; Alday, Portia; Fulache, Mila; Lumagui, Richard; Jorgensen, Pernille; Bell, David; Harvey, Steven
2007-01-01
The usefulness of rapid diagnostic tests (RDT) in malaria case management depends on the accuracy of the diagnoses they provide. Despite their apparent simplicity, previous studies indicate that RDT accuracy is highly user-dependent. As malaria RDTs will frequently be used in remote areas with little supervision or support, minimising mistakes is crucial. This paper describes the development of new instructions (job aids) to improve health worker performance, based on observations of common errors made by remote health workers and villagers in preparing and interpreting RDTs, in the Philippines and Laos. Initial preparation using the instructions provided by the manufacturer was poor, but improved significantly with the job aids (e.g. correct use both of the dipstick and cassette increased in the Philippines by 17%). However, mistakes in preparation remained commonplace, especially for dipstick RDTs, as did mistakes in interpretation of results. A short orientation on correct use and interpretation further improved accuracy, from 70% to 80%. The results indicate that apparently simple diagnostic tests can be poorly performed and interpreted, but provision of clear, simple instructions can reduce these errors. Preparation of appropriate instructions and training as well as monitoring of user behaviour are an essential part of rapid test implementation.
Strain Measurement - Unidirectional.
1983-04-20
of vital importance in obtaining accurate reproducible measurements. This preparation should develop a chemically clean surface having a roughness...testing weapon systems, when parts are stressed to the highest permissible values, and in measuring linear and torsional strains engen - dered by the
Warth, Arne; Muley, Thomas; Meister, Michael; Weichert, Wilko
2015-01-01
Preanalytic sampling techniques and preparation of tissue specimens strongly influence analytical results in lung tissue diagnostics both on the morphological but also on the molecular level. However, in contrast to analytics where tremendous achievements in the last decade have led to a whole new portfolio of test methods, developments in preanalytics have been minimal. This is specifically unfortunate in lung cancer, where usually only small amounts of tissue are at hand and optimization in all processing steps is mandatory in order to increase the diagnostic yield. In the following, we provide a comprehensive overview on some aspects of preanalytics in lung cancer from the method of sampling over tissue processing to its impact on analytical test results. We specifically discuss the role of preanalytics in novel technologies like next-generation sequencing and in the state-of the-art cytology preparations. In addition, we point out specific problems in preanalytics which hamper further developments in the field of lung tissue diagnostics.
Does Test Preparation Work? Implications for Score Validity
ERIC Educational Resources Information Center
Xie, Qin
2013-01-01
This article reports an empirical study that examined the pattern of test preparation for College English Test Band 4 (CET4) and the differential effects of test preparation practices on its scores, thereby drawing implications for CET4 score validity. Data collection involved 1,003 test takers of CET4. A pretest was administered at the beginning…
Heat storage capability of a rolling cylinder using Glauber's salt
NASA Technical Reports Server (NTRS)
Herrick, C. S.; Zarnoch, K. P.
1980-01-01
The rolling cylinder phase change heat storage concept was developed to the point where a prototype design is completed and a cost analysis is prepared. A series of experimental and analytical tasks are defined to establish the thermal, mechanical, and materials behavior of rolling cylinder devices. These tasks include: analyses of internal and external heat transfer; performance and lifetime testing of the phase change materials; corrosion evaluation; development of a mathematical model; and design of a prototype and associated test equipment.
Antibacterial effects of minerals from ores indigenous to Korea.
Park, Seul Ki; Lee, Chang Won; Lee, Mi Young
2009-01-01
We tested the antibacterial properties of a mix of minerals consisting mainly of sericite, talc, and halloysite from Korea. The preparation showed clear growth inhibition of the gram-negative bacteria Escherichia coli and Pseudomonas aeruginosa, and the gram-positive bacteria Staphylococcus aureus subsp. aureus, S. epidermidis, and Bacillus cereus, as well as the anaerobic bacterium Propionibacterium acnes. These results indicate that this preparation, made from ore minerals indigenous to Korea, could be used to develop new antibacterial reagents.
[Possibility of using flour of pigeon pea in products prepared with rice or wheat flour].
Mueses, C; de León, L; Bressani, R
1993-03-01
The present study reports on the development of foods containing processed pigeon pea (Cajanus cajan) flour. The pigeon pea flours described in a previous publication were prepared from dehulled pigeon peas by cooking in autoclave, by extrusion-cooking and by cooking/dehydration by drum-drying. Mixtures of cooked pigeon peas and rice were first evaluated biological through a protein complementation design using NPR. The results of this study showed that the two products had high protein quality and were similar when mixed in ratios of 80:20 to 40:60. For the evaluation of the processed pigeon pea flour, mixtures with rice (80:20) were used. All pigeon pea flours gave similar protein quality values. On the basis of these results three products were developed and tested. One was a gruel ("atole"), a second a fruit-flavored thick drink with and without 15% milk. Cookies were also prepared with a series of blends of pigeon pea flour (extrusion-cooked) and wheat. The gruel and the fruit flavored products had high acceptability based on a sensory evaluation test. Cookies with 100% pigeon pea flour were unacceptable, however, mixtures of 75% wheat flour and 25% pigeon pea flour gave cookies of attractive appearance and good taste. The study showed the possibility of preparing and utilizing tropical grain legume flours for food products of relatively high acceptability and nutritive value.
NASA Astrophysics Data System (ADS)
Gu, Yu; Li, Qiang
2015-07-01
A new method was developed based on the electron beam vacuum dispersion (EBVD) technology to prepare the PTFE polymer coating of the new polymer quartz piezoelectric crystal sensor for testing liquor products. The new method was applied in the new EBVD equipment which we designed. A real-time system monitoring the polymer coating’s thickness was designed for the new EBVD equipment according to the quartz crystal microbalance (QCM) principle, playing an important role in preparing stable and uniform PTFE polymer coatings of the same thickness. 30 pieces of PTFE polymer coatings on the surface of the quartz crystal basis were prepared with the PTFE polymer ultrafine powder (purity ≥ 99.99%) as the starting material. We obtained 30 pieces of new PTFE polymer sensors. By using scanning electron microscopy (SEM), the structure of the PTFE polymer coating’s column clusters was studied. One sample from the 30 pieces of new PTFE polymer sensors was analysed by SEM in four scales, i.e., 400×, 1000×, 10000×, and 25000×. It was shown that under the condition of high bias voltage and low bias current, uniformly PTFE polymer coating could be achieved, which indicates that the new EBVD equipment is suitable for mass production of stable and uniform polymer coating. Project supported by the National High Technology Research and Development Program of China (Grant No. 2013AA030901).
Parodi, Brunella; Russo, Eleonora; Baldassari, Sara; Zuccari, Guendalina; Pastorino, Sara; Yan, Mengying; Neduri, Karthik; Caviglioli, Gabriele
2017-06-01
The aim of this work was the development of mucoadhesive sublingual films, prepared using a casting method, for the administration of oxycodone. A solvent casting method was employed to prepare the mucoadhesive films. A calibrated pipette was used to deposit single aliquots of different polymeric solutions on a polystyrene plate lid. Among the various tested polymers, hydroxypropylcellulose at low and medium molecular weight (HPC) and pectin at two different degrees of esterification (PC) were chosen for preparing solutions with good casting properties, capable of producing films suitable for mucosal application. The obtained films showed excellent drug content uniformity and stability and rapid drug release, which, at 8 min, ranged from 60% to 80%. All films presented satisfactory mucoadhesive and mechanical properties, also confirmed by a test on healthy volunteers, who did not experience irritation or mucosa damages. Pectin films based on pectin at lower degrees of esterification have been further evaluated to study the influence of two different amounts of drug on the physicochemical properties of the formulation. A slight reduction in elasticity has been observed in films containing a higher drug dose; nevertheless, the formulation maintained satisfactory flexibility and resistance to elongation. HPC and PC sublingual films, obtained by a simple casting method, could be proposed to realize personalized hospital pharmacy preparations on a small scale.
Development of freeze dried vegetables
NASA Technical Reports Server (NTRS)
Larson, R. W.
1970-01-01
The development of freeze dried vegetables to be used in the Apollo food system is discussed. After the initial selection and screening of vegetables, several types of freeze dried vegetables were prepared in small batches. From these small batches, two vegetables were judged satisfactory for further testing and evaluation. These vegetables, mashed potatoes and asparagus, were subjected to storage at 100 deg plus or minus 5 F. for two weeks and then taste tested. The vegetables were also tested to determine if they complied with the microbiological requirements for Apollo food. The space food prototype production guide for the vegetables is submitted.
Does Test Preparation Mean Low-Quality Instruction?
ERIC Educational Resources Information Center
Blazar, David; Pollard, Cynthia
2017-01-01
Critics of test-based accountability warn that test preparation has a negative influence on teachers' instruction due to a focus on procedural skills. Others advocate that the adoption of more rigorous assessments may be a way to incentivize more ambitious test preparation instruction. Drawing on classroom observations and teacher surveys, we do…
40 CFR 86.1334-84 - Pre-test engine and dynamometer preparation.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 19 2010-07-01 2010-07-01 false Pre-test engine and dynamometer preparation. 86.1334-84 Section 86.1334-84 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Exhaust Test Procedures § 86.1334-84 Pre-test engine and dynamometer preparation. (a) Control system...
40 CFR 86.1334-84 - Pre-test engine and dynamometer preparation.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 20 2012-07-01 2012-07-01 false Pre-test engine and dynamometer preparation. 86.1334-84 Section 86.1334-84 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Exhaust Test Procedures § 86.1334-84 Pre-test engine and dynamometer preparation. (a) Control system...
40 CFR 86.1334-84 - Pre-test engine and dynamometer preparation.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 19 2011-07-01 2011-07-01 false Pre-test engine and dynamometer preparation. 86.1334-84 Section 86.1334-84 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Exhaust Test Procedures § 86.1334-84 Pre-test engine and dynamometer preparation. (a) Control system...
40 CFR 86.1334-84 - Pre-test engine and dynamometer preparation.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 20 2013-07-01 2013-07-01 false Pre-test engine and dynamometer preparation. 86.1334-84 Section 86.1334-84 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Exhaust Test Procedures § 86.1334-84 Pre-test engine and dynamometer preparation. (a) Control system...
40 CFR 86.1910 - How must I prepare and test my in-use engines?
Code of Federal Regulations, 2012 CFR
2012-07-01
... new test. In this case, only the post-repair test results would be used in the vehicle-pass... 40 Protection of Environment 20 2012-07-01 2012-07-01 false How must I prepare and test my in-use...) Manufacturer-Run In-Use Testing Program for Heavy-Duty Diesel Engines § 86.1910 How must I prepare and test my...
Tensile-Creep Test Specimen Preparation Practices of Surface Support Liners
NASA Astrophysics Data System (ADS)
Guner, Dogukan; Ozturk, Hasan
2017-12-01
Ground support has always been considered as a challenging issue in all underground operations. Many forms of support systems and supporting techniques are available in the mining/tunnelling industry. In the last two decades, a new polymer based material, Thin Spray-on Liner (TSL), has attained a place in the market as an alternative to the current areal ground support systems. Although TSL provides numerous merits and has different application purposes, the knowledge on mechanical properties and performance of this material is still limited. In laboratory studies, since tensile rupture is the most commonly observed failure mechanism in field applications, researchers have generally studied the tensile testing of TSLs with modification of American Society for Testing and Materials (ASTM) D-638 standards. For tensile creep testing, specimen preparation process also follows the ASTM standards. Two different specimen dimension types (Type I, Type IV) are widely preferred in TSL tensile testing that conform to the related standards. Moreover, molding and die cutting are commonly used specimen preparation techniques. In literature, there is a great variability of test results due to the difference in specimen preparation techniques and practices. In this study, a ductile TSL product was tested in order to investigate the effect of both specimen preparation techniques and specimen dimensions under 7-day curing time. As a result, ultimate tensile strength, tensile yield strength, tensile modulus, and elongation at break values were obtained for 4 different test series. It is concluded that Type IV specimens have higher strength values compared to Type I specimens and moulded specimens have lower results than that of prepared by using die cutter. Moreover, specimens prepared by molding techniques have scattered test results. Type IV specimens prepared by die cutter technique are suggested for preparation of tensile test and Type I specimens prepared by die cutter technique should be preferred for tensile creep tests.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cheng, Jian; Department of Physics, The Ohio State University, 191 W. Woodruff Ave, Columbus, OH 43210; Chen, Mingjun, E-mail: chenmj@hit.edu.cn, E-mail: chowdhury.24@osu.edu
Rapid growth and ultra-precision machining of large-size KDP (KH{sub 2}PO{sub 4}) crystals with high laser damage resistance are tough challenges in the development of large laser systems. It is of high interest and practical significance to have theoretical models for scientists and manufacturers to determine the laser-induced damage threshold (LIDT) of actually prepared KDP optics. Here, we numerically and experimentally investigate the laser-induced damage on KDP crystals in ultra-short pulse laser regime. On basis of the rate equation for free electron generation, a model dedicated to predicting the LIDT is developed by considering the synergistic effect of photoionization, impact ionizationmore » and decay of electrons. Laser damage tests are performed to measure the single-pulse LIDT with several testing protocols. The testing results combined with previously reported experimental data agree well with those calculated by the model. By taking the light intensification into consideration, the model is successfully applied to quantitatively evaluate the effect of surface flaws inevitably introduced in the preparation processes on the laser damage resistance of KDP crystals. This work can not only contribute to further understanding of the laser damage mechanisms of optical materials, but also provide available models for evaluating the laser damage resistance of exquisitely prepared optical components used in high power laser systems.« less
Historical Survey of Research in Physics Teacher Preparation
NASA Astrophysics Data System (ADS)
Meltzer, David E.
2017-01-01
There have been efforts to provide specialized preparation for prospective physics teachers for over 100 years, both in the U.S. and elsewhere. However, systematic research investigations of these efforts are much more scarce, particularly in the U.S. I will review some highlights of research in physics teacher preparation reported in the U.S. and in several other countries as early as the 1920s. The more recent investigations (beginning around 1970) reveal a pattern of teacher preparation practices emphasizing multiple, extended experiences in analyzing physical systems-and making and testing hypotheses of experimental outcomes-by developing and reflecting on laboratory-based physics activities that are often subsequently taught (as simulated ``micro-teaching'' or in actual classrooms), all under close guidance and intensive coaching from expert physics-teacher educators. Outcomes reported include improvements in the quality of experiment design (emphasizing student-generated explanations rather than rote procedures), and in ability to communicate, better awareness of physics teachers' pedagogical knowledge, and improved learning gains by the teachers' students on tests of conceptual understanding. Supported in part by NSF DUE #1256333.
A noise control package for vibrating screens1),2)
Lowe, M. Jenae; Yantek, David S.; Yang, Junyi; Schuster, Kevin C.; Mechling, Jessie J.
2015-01-01
Hearing loss was the second-most common illness reported to the Mine Safety and Health Administration (MSHA) in 2009. Furthermore, between 2000 and 2010, 30% of all noise-related injury complaints reported to MSHA were for coal preparation plant employees. Previous National Institute for Occupational Safety and Health (NIOSH) studies have shown that vibrating screens are key noise sources to address in order to reduce coal preparation plant noise. In response, NIOSH researchers have developed a suite of noise controls for vibrating screens consisting of constrained layer damping (CLD) treatments, a tuned mechanism suspension, an acoustic enclosure, and spring inserts. Laboratory testing demonstrates that this noise control suite reduces the A-weighted sound power level of the vibrating screen by 6 dB. To provide a comparison to laboratory results and prove durability, field testing of two noise controls was performed on a vibrating screen in a working coal preparation plant. The spring inserts and CLD treatments were selected due to their ease of installation and practicability. Field testing of these controls yielded reductions that were comparable to laboratory results. PMID:26257468
Highly attrition-resistant zinc oxide-based sorbents for H{sub 2}S removal by spray-drying technique
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, J.B.; Baek, J.I.; Ryu, C.K.
2008-07-15
A ZnO-based sorbent, ZAC 32N, applicable to transport reactors was successfully prepared by the spray-drying technique. Another sorbent, ZAC 32SU, was prepared by scale-up preparation of ZAC 32N sorbent. The physical properties of the sorbents such as attrition resistance, specific surface area, pore volume, and particle size were extensively characterized and exhibited a good potential for use in transport applications. The chemical reactivity tested in the thermogravimetric analyzer and microreactor exhibited desirable characteristics for effective desulfurization of syngas streams in the range of 450-550{sup o}C. Bench-scale tests for the sorbent ZAC 32SU were performed for a continuous 160 h withmore » a steady solid circulation of 54.6 kg/h. The results showed 99.5%+ desulfurization at 500-550{sup o}C and reasonable regenerability at 550-620{sup o}C. Test results on the physical properties and chemical reactivity indicated that the performance of developed sorbents proved to be outstanding.« less
SRB Processing Facilities Media Event
2016-03-01
Members of the news media view the high bay inside the Rotation, Processing and Surge Facility (RPSF) at NASA’s Kennedy Space Center in Florida. Kerry Chreist, with Jacobs Engineering on the Test and Operations Support Contract, talks with a reporter about the booster segments for NASA’s Space Launch System (SLS) rocket. In the far corner, in the vertical position, is one of two pathfinders, or test versions, of solid rocket booster segments for the SLS rocket. The Ground Systems Development and Operations Program and Jacobs are preparing the booster segments, which are inert, for a series of lifts, moves and stacking operations to prepare for Exploration Mission-1, deep-space missions and the journey to Mars.
Orion's Neutral Buoyancy Lab (NBL) Activities
2016-09-21
Tim Goddard, center, NASA Open Water Recovery Operations director, reviews recovery procedures with U.S. Navy divers, Air Force pararescuemen and Coast Guard rescue swimmers during training in the Neutral Buoyancy Laboratory at NASA’s Johnson Space Center in Houston. The group is practicing Orion underway recovery techniques using a test version of the Orion spacecraft. Training will help the team prepare for Underway Recovery Test 5 for Exploration Mission 1 aboard the USS San Diego in the Pacific Ocean off the coast of California in October. The Ground Systems Development and Operations Program, along with the U.S. Navy and Lockheed Martin, are preparing the recovery team, hardware and operations to support EM-1 recovery.
Rodent repellents: Preparation and properties of thiouronium compounds and cyclic imides
Bellack, E.; DeWitt, J.B.
1954-01-01
Syntheses and bioassays of cyclic imides and thiouronium compounds were carried out as part of a search for materials capable of preventing rodent damage to packaged commodities. Previous studies had shown that repellent activity was associated with functional groups containing nitrogen and sulfur, and was enhanced by the presence of ionic linkages. Twenty-seven thiouronium compounds and 40 imides, including 1 0 compounds not described previously, were prepared for these tests. Ten imides and 26 thiouronium compounds were repellent under the conditions of test. Information obtained in these studies will be utilized in the development and selection of more effective materials for prevention of rodent damage to foods and other commodities.
Lunar Polar Environmental Testing: Regolith Simulant Conditioning
NASA Technical Reports Server (NTRS)
Kleinhenz, Julie
2014-01-01
As ISRU system development approaches flight fidelity, there is a need to test hardware in relevant environments. Extensive laboratory and field testing have involved relevant soil (lunar regolith simulants), but the current design iterations necessitate relevant pressure and temperature conditions. Including significant quantities of lunar regolith simulant in a thermal vacuum chamber poses unique challenges. These include facility operational challenges (dust tolerant hardware) and difficulty maintaining a pre-prepared soil state during pump down (consolidation state, moisture retention).For ISRU purposes, the regolith at the lunar poles will be of most interest due to the elevated water content. To test at polar conditions, the regolith simulant must be doped with water to an appropriate percentage and then chilled to cryogenic temperatures while exposed to vacuum conditions. A 1m tall, 28cm diameter bin of simulant was developed for testing these simulant preparation and drilling operations. The bin itself was wrapped with liquid nitrogen cooling loops (100K) so that the simulant bed reached an average temperature of 140K at vacuum. Post-test sampling was used to determine desiccation of the bed due to vacuum exposure. Depth dependent moisture data is presented from frozen and thawed soil samples.Following simulant only evacuation tests, drill hardware was incorporated into the vacuum chamber to test auguring techniques in the frozen soil at thermal vacuum conditions. The focus of this testing was to produce cuttings piles for a newly developed spectrometer to evaluate. This instrument, which is part of the RESOLVE program science hardware, detects water signatures from surface regolith. The drill performance, behavior of simulant during drilling, and characteristics of the cuttings piles will be offered.
Preparing for Flight Engine Test
2015-11-04
The first RS-25 flight engine, engine No. 2059, is lifted onto the A-1 Test Stand at Stennis Space Center on Nov. 4, 2015. The engine was tested in early 2016 to certify it for use on NASA’s new Space Launch System (SLS). The SLS core stage will be powered by four RS-25 engines, all tested at Stennis Space Center. NASA is developing the SLS to carry humans deeper into space than ever before, including on a journey to Mars.
Testing and Evaluation of Multifunctional Smart Coatings
NASA Technical Reports Server (NTRS)
Buhrow, Jerry; Li, Wenyan; Jolley, Scott; Calle, Luz M.; Pearman, Benjamin; Zhang, Xuejun
2015-01-01
A smart coating system, based on pH sensitive microcontainers (microparticles and microcapsules) has been developed. Various corrosion inhibitors have been encapsulated and incorporated into commercial and formulated coatings to test the functionality imparted on the coating by the incorporation of the inhibitor microcontainers. Coated carbon steel and aluminum alloy panels were tested using salt immersion, salt fog, and coastal atmospheric exposure conditions. This paper provides the details on coating sample preparation, evaluation methods, as well as test results of the inhibiting function of smart coatings.
NASA Astrophysics Data System (ADS)
Dudung, Agus
2018-03-01
The purpose of this study of Teacher Competency Test (UKG) is to know about (a) the description of the vocational school teachers' competency test result majoring light vehicle subject in eastern Jakarta, (b) the effect between those certified teachers, non-certified teachers, civil servant teachers and non-civil servant teachers to Teacher Competency Test (UKG) result. The UKG result indicates that (1) certified teachers hold the highest score, however non-certified teachers obtain at the average of 55, in terms of UKG technicality preparation; (2) there are 43 teachers (48.9%) mention that the room facility for conducting UKG is good, while 45 teachers (51.1%) mention the opposite opinion. This shows that the average UKG room is relatively good enough. Meanwhile, in terms of youth facilities availability, (3) there are 86 teachers (97.7%) agree that the facilities are good while 2 teachers (2.3%) say the opposite opinion. This shows that the average UKG preparation is relatively very good. About the implementation of UKG, (4) there are 65 teachers (73,9%) give good impression, while 23 teachers (26,1%) give poor quality impression. This shows that the average UKG implementation is relatively good. About the way UKG is managed, (5) there are 87 teachers (98,9%) identify satisfactory comments, while there is only 1 teacher (1,1%) gives unsatisfactory comment. This shows that the average UKG management is relatively very good. ANNOVA analysis is used in this study to estimate the effect of UKG on certified and non-certified teachers. The ANNOVA test result shows that (6) H_0 is accepted because α = 0,05 <0,423 at the 5% level. UKG gives no effect for both certified and non-certified teachers. This study suggests (1) that the teachers necessarily prepare themselves to face UKG while the Government prepares the supporting facilities such as (a) test Room, (b) UKG readiness, (c) UKG implementation (d) UKG management including UKG materials. (2) The grid in the given test should (a) represent the content of the syllabus/curriculum or materials that teachers teach appropriately and proportionately (b) represent the components which are clearly and easily understood by the teachers as participants of the UKG. (3) Teachers' assessment has to give more concern to UKG selection which is based on their class performance, track record, and self-development. (4) The UKG shall be conducted only for mapping and shall be followed up with teacher training in the form of more directed education and training for both pedagogical and professional competence. (5) For the preparation, initially the teachers can learn from the grid given by the Ministry of Education and Culture (6) Teachers' assessment has to give more concern to UKG selectivity based on their class performance, track record, and self-development. (7) UKG shall be followed up by teacher training in the form of education and more directed trainings by also providing continuous training (PKB). Thus, the development of sustainable profession will be developed and will create a culture of quality among teachers.
Ada Programming Support Environment (APSE) Evaluation and Validation (E&V) Team
1991-12-31
standards. The purpose of the team was to assist the project in several ways. Raymond Szymanski of Wright Research Iand Development Center (WRDC, now...debuggers, program library systems, and compiler diagnostics. The test suite does not include explicit tests for the existence of language features . The...support software is a set of tools and procedures which assist in preparing and executing the test suite, in extracting data from the results of
Preparation and preclinical evaluation of 68Ga-DOTA-amlodipine for L-type calcium channel imaging
Firuzyar, Tahereh; Jalilian, Amir Reza; Aboudzadeh, Mohammad Reza; Sadeghpour, Hossein; Shafiee-Ardestani, Mahdi; Khalaj, Ali
2016-01-01
Aim: In order to develop a possible tracer for L-type calcium channel imaging, we here report the development of a Ga-68 amlodipine derivative for possible PET imaging. Materials and Methods: Amlodipine DOTA conjugate was synthesized, characterized and went through calcium channel blockade, toxicity, apoptosis/necrosis tests. [68Ga] DOTA AMLO was prepared at optimized conditions followed by stability tests, partition coefficient determination and biodistribution studies using tissue counting and co incidence imaging up to 2 h. Results: [68Ga] DOTA AMLO was prepared at pH 4–5 in 7–10 min at 95°C in high radiochemical purity (>99%, radio thin layer chromatography; specific activity: 1.9–2.1 GBq/mmol) and was stable up to 4 h with a log P of −0.94. Calcium channel rich tissues including myocardium, and tissues with smooth muscle cells such as colon, intestine, and lungs demonstrated significant uptake. Co incidence images supported the biodistribution data up to 2 h. Conclusions: The complex can be a candidate for further positron emission tomography imaging for L type calcium channels. PMID:27833311
3D Printing of Thermo-Responsive Methylcellulose Hydrogels for Cell-Sheet Engineering.
Cochis, Andrea; Bonetti, Lorenzo; Sorrentino, Rita; Contessi Negrini, Nicola; Grassi, Federico; Leigheb, Massimiliano; Rimondini, Lia; Farè, Silvia
2018-04-10
A possible strategy in regenerative medicine is cell-sheet engineering (CSE), i.e., developing smart cell culture surfaces from which to obtain intact cell sheets (CS). The main goal of this study was to develop 3D printing via extrusion-based bioprinting of methylcellulose (MC)-based hydrogels. Hydrogels were prepared by mixing MC powder in saline solutions (Na₂SO₄ and PBS). MC-based hydrogels were analyzed to investigate the rheological behavior and thus optimize the printing process parameters. Cells were tested in vitro on ring-shaped printed hydrogels; bulk MC hydrogels were used for comparison. In vitro tests used murine embryonic fibroblasts (NIH/3T3) and endothelial murine cells (MS1), and the resulting cell sheets were characterized analyzing cell viability and immunofluorescence. In terms of CS preparation, 3D printing proved to be an optimal approach to obtain ring-shaped CS. Cell orientation was observed for the ring-shaped CS and was confirmed by the degree of circularity of their nuclei: cell nuclei in ring-shaped CS were more elongated than those in sheets detached from bulk hydrogels. The 3D printing process appears adequate for the preparation of cell sheets of different shapes for the regeneration of complex tissues.
2010-01-01
Background Competing causes of mortality in the elderly decrease the potential net benefit from colorectal cancer screening and increase the likelihood of potential harms. Individualized decision making has been recommended, so that the elderly can decide whether or not to undergo colorectal cancer (CRC) screening. The objective is to develop and test a decision aid designed to promote individualized colorectal cancer screening decision making for adults age 75 and over. Methods We used formative research and cognitive testing to develop and refine the decision aid. We then tested the decision aid in an uncontrolled trial. The primary outcome was the proportion of patients who were prepared to make an individualized decision, defined a priori as having adequate knowledge (10/15 questions correct) and clear values (25 or less on values clarity subscale of decisional conflict scale). Secondary outcomes included overall score on the decisional conflict scale, and preferences for undergoing screening. Results We enrolled 46 adults in the trial. The decision aid increased the proportion of participants with adequate knowledge from 4% to 52% (p < 0.01) and the proportion prepared to make an individualized decision from 4% to 41% (p < 0.01). The proportion that preferred to undergo CRC screening decreased from 67% to 61% (p = 0. 76); 7 participants (15%) changed screening preference (5 against screening, 2 in favor of screening) Conclusion In an uncontrolled trial, the elderly participants appeared better prepared to make an individualized decision about whether or not to undergo CRC screening after using the decision aid. PMID:20849625
Stability of extemporaneously prepared preservative-free prochlorperazine nasal spray.
Yellepeddi, Venkata K
2018-01-01
The stability of an extemporaneously prepared preservative-free prochlorperazine 5-mg/mL nasal spray was evaluated. The preservative-free prochlorperazine nasal spray was prepared by adding 250 mg of prochlorperazine edisylate to 50 mL of citrate buffer in a low-density polyethylene nasal spray bottle. A stability-indicating high-performance liquid chromatography (HPLC) method was developed and validated using the major degradant prochlorperazine sulfoxide and by performing forced-degradation studies. For chemical stability studies, 3 100-μL samples of the preservative-free prochlorperazine from 5 nasal spray bottles stored at room temperature were collected at days 0, 20, 30, 45, and 60 and were assayed in triplicate using the stability-indicating HPLC method. Microbiological testing involved antimicrobial effectiveness testing based on United States Pharmacopeia ( USP ) chapter 51 and quantitative microbiological enumeration of aerobic bacteria, yeasts, and mold based on USP chapter 61. Samples for microbiological testing were collected at days 0, 30, and 60. The stability-indicating HPLC method clearly identified the degradation product prochlorperazine sulfoxide without interference from prochlorperazine. All tested solutions retained over 90% of the initial prochlorperazine concentration for the 60-day study period. There were no detectable changes in color, pH, and viscosity in any sample. There was no growth of bacteria, yeast, and mold for 60 days in all samples tested. An extemporaneously prepared preservative-free nasal spray solution of prochlorperazine edisylate 5 mg/mL was physically, chemically, and microbiologically stable for 60 days when stored at room temperature in low-density polyethylene bottles. Copyright © 2018 by the American Society of Health-System Pharmacists, Inc. All rights reserved.
Serology of Paracoccidioidomycosis Due to Paracoccidioides lutzii
Gegembauer, Gregory; Araujo, Leticia Mendes; Pereira, Edy Firmina; Rodrigues, Anderson Messias; Paniago, Anamaria Mello Miranda; Hahn, Rosane Christine; de Camargo, Zoilo Pires
2014-01-01
Paracoccidioides lutzii is a new agent of paracoccidioidomycosis (PCM) and has its epicenter localized to the Central-West region of Brazil. Serological diagnosis of PCM caused by P. lutzii has not been established. This study aimed to develop new antigenic preparations from P. lutzii and to apply them in serological techniques to improve the diagnosis of PCM due to P. lutzii. Paracoccidioides lutzii exoantigens, cell free antigen (CFA), and a TCA-precipitated antigen were evaluated in immunodiffusion (ID) tests using a total of 89 patient sera from the Central-West region of Brazil. Seventy-two sera were defined as reactive for P. brasiliensis using traditional antigens (AgPbB339 and gp43). Non-reactive sera for traditional antigens (n = 17) were tested with different P. lutzii preparations and P. lutzii CFA showed 100% reactivity. ELISA was found to be a very useful test to titer anti-P. lutzii antibodies using P. lutzii-CFA preparations. Sera from patients with PCM due to P. lutzii presented with higher antibody titers than PCM due to P. brasiliensis and heterologous sera. In western blot, sera from patients with PCM due to P. lutzii were able to recognize antigenic molecules from the P. lutzii-CFA antigen, but sera from patients with PCM due to P. brasiliensis could not recognize any P. lutzii molecules. Due to the facility of preparing P. lutzii CFA antigens we recommend its use in immunodiffusion tests for the diagnosis of PCM due to P. lutzii. ELISA and western blot can be used as complementary tests. PMID:25032829
Hatchette, Todd F; Bastien, Nathalie; Berry, Jody; Booth, Tim F; Chernesky, Max; Couillard, Michel; Drews, Steven; Ebsworth, Anthony; Fearon, Margaret; Fonseca, Kevin; Fox, Julie; Gagnon, Jean-Nicolas; Guercio, Steven; Horsman, Greg; Jorowski, Cathy; Kuschak, Theodore; Li, Yan; Majury, Anna; Petric, Martin; Ratnam, Sam; Smieja, Marek; Van Caeseele, Paul
2009-01-01
As the world prepares for the next influenza pandemic, governments have made significant funding commitments to vaccine development and antiviral stockpiling. While these are essential components to pandemic response, rapid and accurate diagnostic testing remains an often neglected cornerstone of pandemic influenza preparedness. Clinicians and Public Health Practitioners need to understand the benefits and drawbacks of different influenza tests in both seasonal and pandemic settings. Culture has been the traditional gold standard for influenza diagnosis but requires from 1-10 days to generate a positive result, compared to nucleic acid detection methods such as real time reverse transcriptase polymerase chain reaction (RT-PCR). Although the currently available rapid antigen detection kits can generate results in less than 30 minutes, their sensitivity is suboptimal and they are not recommended for the detection of novel influenza viruses. Until point-of-care (POC) tests are improved, PILPN recommends that the best option for pandemic influenza preparation is the enhancement of nucleic acid-based testing capabilities across Canada.
Fura, Louise A; Wisser, Kathleen Z
Nurse educators are charged to develop and evaluate curricula on systems thinking to prepare future nurses to provide safe nursing care. The goal of this pilot study was to design and evaluate a four-hour educational strategy that prepares future professional nurses to use systems thinking approaches in the delivery of safe patient care. This study exposed prelicensure baccalaureate nursing students to systems thinking principles, which included didactic and experiential activities. A descriptive design was used to determine the effect of an on-campus educational strategy. A paired samples t-test revealed statistical significance from pretest to posttest.
46 CFR 61.05-5 - Preparation of boilers for inspection and test.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 2 2012-10-01 2012-10-01 false Preparation of boilers for inspection and test. 61.05-5 Section 61.05-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PERIODIC TESTS AND INSPECTIONS Tests and Inspections of Boilers § 61.05-5 Preparation of boilers for inspection and test. (a) For internal inspectio...
ERIC Educational Resources Information Center
Liu, Ou Lydia
2014-01-01
This study investigates the relationship between test preparation and test performance on the "TOEFL iBT"® exam. Information on background variables and test preparation strategies was gathered from 14,593 respondents in China through an online survey. A Chinese standardized English test was used as a control for prior English ability.…
ERIC Educational Resources Information Center
Nowinski, Wieslaw L.; Thirunavuukarasuu, Arumugam; Ananthasubramaniam, Anand; Chua, Beng Choon; Qian, Guoyu; Nowinska, Natalia G.; Marchenko, Yevgen; Volkau, Ihar
2009-01-01
Preparation of tests and student's assessment by the instructor are time consuming. We address these two tasks in neuroanatomy education by employing a digital media application with a three-dimensional (3D), interactive, fully segmented, and labeled brain atlas. The anatomical and vascular models in the atlas are linked to "Terminologia…
Education Career Ladder, AFSC 751X0. Volume II.
1981-02-01
the functions listed in both documents, such as: testing; counseling; conducting educational surveys; collecting and analyzing statistical data; and...Inventory Development The instrument used for data collection for the occupational survey was USAF Job Inventory AFPT 90-751-408. As a starting point, the...testing; preparing, conducting, or evaluating educrtional surveys; collecting and analyzing statistical data; or organizing group study classes. This
ERIC Educational Resources Information Center
Lahey, Benjamin B.; Applegate, Brooks; Chronis, Andrea M.; Jones, Heather A.; Williams, Stephanie Hall; Loney, Jan; Waldman, Irwin D.
2008-01-01
Lahey and Waldman proposed a developmental propensity model in which three dimensions of children's emotional dispositions are hypothesized to transact with the environment to influence risk for conduct disorder, heterogeneity in conduct disorder, and comorbidity with other disorders. To prepare for future tests of this model, a new measure of…
USDA-ARS?s Scientific Manuscript database
A rapid lateral flow fluorescent microspheres immunochromatography test strip (FMs-ICTS) has been developed for the detection of aflatoxin M1 (AFM1) residues in milk. For this purpose, an ultra-sensitive anti-AFM1 monoclonal antibody (MAb) 1D3 was prepared and identified. The IC50 value of the MA...
As a precursor to the National Children's Study (NCS), the North Carolina Cohort Study (NC Cohort Study) will provide the opportunity to field test procedures to better inform the implementation of the NCS. In order to test some of the study hypotheses, it will be important to ob...
2013-01-01
Background The use of substandard and degraded medicines is a major public health problem in developing countries such as Cambodia. A collaborative study was conducted to evaluate the quality of amoxicillin–clavulanic acid preparations under tropical conditions in a developing country. Methods Amoxicillin-clavulanic acid tablets were obtained from outlets in Cambodia. Packaging condition, printed information, and other sources of information were examined. The samples were tested for quantity, content uniformity, and dissolution. Authenticity was verified with manufacturers and regulatory authorities. Results A total of 59 samples were collected from 48 medicine outlets. Most (93.2%) of the samples were of foreign origin. Using predetermined acceptance criteria, 12 samples (20.3%) were non-compliant. Eight (13.6%), 10 (16.9%), and 20 (33.9%) samples failed quantity, content uniformity, and dissolution tests, respectively. Samples that violated our observational acceptance criteria were significantly more likely to fail the quality tests (Fisher’s exact test, p < 0.05). Conclusions Improper packaging and storage conditions may reduce the quality of amoxicillin–clavulanic acid preparations at community pharmacies. Strict quality control measures are urgently needed to maintain the quality of amoxicillin–clavulanic acid in tropical countries. PMID:23773420
Lange, Rogier; Ter Heine, Rob; van der Gronde, Toon; Selles, Suzanne; de Klerk, John; Bloemendal, Haiko; Hendrikse, Harry
2016-07-30
Rhenium-188-HEDP ((188)Re-HEDP) is a therapeutic radiopharmaceutical for treatment of osteoblastic bone metastases. No standard procedure for the preparation of this radiopharmaceutical is available. Preparation conditions may influence the quality and in vivo behaviour of this product. In this study we investigate the effect of critical process parameters on product quality and stability of (188)Re-HEDP. A stepwise approach was used, based on the quality by design (QbD) concept of the ICH Q8 (Pharmaceutical Development) guideline. Potential critical process conditions were identified. Variables tested were the elution volume, the freshness of the eluate, the reaction temperature and time, and the stability of the product upon dilution and storage. The impact of each variable on radiochemical purity was investigated. The acceptable ranges were established by boundary testing. With 2ml eluate, adequate radiochemical purity and stability were found. Nine ml eluate yielded a product that was less stable. Using eluate stored for 24h resulted in acceptable radiochemical purity. Complexation for 30min at room temperature, at 60°C and at 100°C generated appropriate and stable products. A complexation time of 10min at 90°C was too short, whereas heating 60min resulted in products that passed quality control and were stable. Diluting the end product and storage at 32.5°C resulted in notable decomposition. Two boundary tests, an elution volume of 9ml and a heating time of 10min, yielded products of inadequate quality or stability. The product was found to be instable after dilution or when stored above room temperature. Our findings show that our previously developed preparation method falls well within the proven acceptable ranges. Applying QbD principles is feasible and worthwhile for the small-scale preparation of radiopharmaceuticals. Copyright © 2016 Elsevier B.V. All rights reserved.
10 CFR 26.89 - Preparing to collect specimens for testing.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 1 2014-01-01 2014-01-01 false Preparing to collect specimens for testing. 26.89 Section 26.89 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.89 Preparing to collect specimens for testing. (a) When an individual has been notified of a...
10 CFR 26.89 - Preparing to collect specimens for testing.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 1 2012-01-01 2012-01-01 false Preparing to collect specimens for testing. 26.89 Section 26.89 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.89 Preparing to collect specimens for testing. (a) When an individual has been notified of a...
10 CFR 26.89 - Preparing to collect specimens for testing.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 1 2013-01-01 2013-01-01 false Preparing to collect specimens for testing. 26.89 Section 26.89 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.89 Preparing to collect specimens for testing. (a) When an individual has been notified of a...
10 CFR 26.89 - Preparing to collect specimens for testing.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 1 2010-01-01 2010-01-01 false Preparing to collect specimens for testing. 26.89 Section 26.89 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.89 Preparing to collect specimens for testing. (a) When an individual has been notified of a...
10 CFR 26.89 - Preparing to collect specimens for testing.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 1 2011-01-01 2011-01-01 false Preparing to collect specimens for testing. 26.89 Section 26.89 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.89 Preparing to collect specimens for testing. (a) When an individual has been notified of a...
ERIC Educational Resources Information Center
Menard, Lauren A.
2011-01-01
Obstacles to the classroom implementation of the fourth grade Math component of Louisiana's web-based testing tutorial were addressed in this informal pilot. Technology integration improved standardized test preparation for students with special needs. Supplemental test preparation sessions give the benefits of (a) increased familiarity with…
Code of Federal Regulations, 2014 CFR
2014-01-01
..., implement, and maintain written standard operating procedures for each assay performed for drug and specimen... facility shall develop, implement, and maintain written standard operating procedures for each test. The...; (2) Preparation of reagents, standards, and controls; (3) Calibration procedures; (4) Derivation of...
Code of Federal Regulations, 2012 CFR
2012-01-01
..., implement, and maintain written standard operating procedures for each assay performed for drug and specimen... facility shall develop, implement, and maintain written standard operating procedures for each test. The...; (2) Preparation of reagents, standards, and controls; (3) Calibration procedures; (4) Derivation of...
Code of Federal Regulations, 2013 CFR
2013-01-01
..., implement, and maintain written standard operating procedures for each assay performed for drug and specimen... facility shall develop, implement, and maintain written standard operating procedures for each test. The...; (2) Preparation of reagents, standards, and controls; (3) Calibration procedures; (4) Derivation of...
CVD diamond pixel detectors for LHC experiments
NASA Astrophysics Data System (ADS)
Wedenig, R.; Adam, W.; Bauer, C.; Berdermann, E.; Bergonzo, P.; Bogani, F.; Borchi, E.; Brambilla, A.; Bruzzi, M.; Colledani, C.; Conway, J.; Dabrowski, W.; Delpierre, P.; Deneuville, A.; Dulinski, W.; van Eijk, B.; Fallou, A.; Fizzotti, F.; Foulon, F.; Friedl, M.; Gan, K. K.; Gheeraert, E.; Grigoriev, E.; Hallewell, G.; Hall-Wilton, R.; Han, S.; Hartjes, F.; Hrubec, J.; Husson, D.; Kagan, H.; Kania, D.; Kaplon, J.; Karl, C.; Kass, R.; Knöpfle, K. T.; Krammer, M.; Logiudice, A.; Lu, R.; Manfredi, P. F.; Manfredotti, C.; Marshall, R. D.; Meier, D.; Mishina, M.; Oh, A.; Pan, L. S.; Palmieri, V. G.; Pernicka, M.; Peitz, A.; Pirollo, S.; Polesello, P.; Pretzl, K.; Procario, M.; Re, V.; Riester, J. L.; Roe, S.; Roff, D.; Rudge, A.; Runolfsson, O.; Russ, J.; Schnetzer, S.; Sciortino, S.; Speziali, V.; Stelzer, H.; Stone, R.; Suter, B.; Tapper, R. J.; Tesarek, R.; Trawick, M.; Trischuk, W.; Vittone, E.; Wagner, A.; Walsh, A. M.; Weilhammer, P.; White, C.; Zeuner, W.; Ziock, H.; Zoeller, M.; Blanquart, L.; Breugnion, P.; Charles, E.; Ciocio, A.; Clemens, J. C.; Dao, K.; Einsweiler, K.; Fasching, D.; Fischer, P.; Joshi, A.; Keil, M.; Klasen, V.; Kleinfelder, S.; Laugier, D.; Meuser, S.; Milgrome, O.; Mouthuy, T.; Richardson, J.; Sinervo, P.; Treis, J.; Wermes, N.; RD42 Collaboration
1999-08-01
This paper reviews the development of CVD diamond pixel detectors. The preparation of the diamond pixel sensors for bump-bonding to the pixel readout electronics for the LHC and the results from beam tests carried out at CERN are described.
On-ground tests of the NISP infrared spectrometer instrument for Euclid
NASA Astrophysics Data System (ADS)
Jomni, Cyril; Ealet, Anne; Gillard, William; Prieto, Éric; Grupp, Frank U.
2017-09-01
Euclid is an ESA mission dedicated to understand the acceleration of the expansion of the Universe. The mission will measure hundred of millions of galaxies in spectrophotometry and photometry in the near infrared thanks to a spectro-photometer called NISP. This instrument will be assembled and tested in Marseille. To prepare the on-ground test plan and develop the test procedure, we have used simulated PSF images, based on a Zemax optical design of the instrument. We have developed the analysis tools that will be further used to build the procedure verification. We present here the method and analysis results to adjust the focus of the instrument. We will in particular show that because of the sampling of the PSF, a dithering strategy should be adapted and will constraint the development of the test plan.
Preparation for Scaling Studies of Ice-Crystal Icing at the NRC Research Altitude Test Facility
NASA Technical Reports Server (NTRS)
Struk, Peter M.; Bencic, Timothy J.; Tsao, Jen-Ching; Fuleki, Dan; Knezevici, Daniel C.
2013-01-01
This paper describes experiments conducted at the National Research Council (NRC) of Canadas Research Altitiude Test Facility between March 26 and April 11, 2012. The tests, conducted collaboratively between NASA and NRC, focus on three key aspects in preparation for later scaling work to be conducted with a NACA 0012 airfoil model in the NRC Cascade rig: (1) cloud characterization, (2) scaling model development, and (3) ice-shape profile measurements. Regarding cloud characterization, the experiments focus on particle spectra measurements using two shadowgraphy methods, cloud uniformity via particle scattering from a laser sheet, and characterization of the SEA Multi-Element probe. Overviews of each aspect as well as detailed information on the diagnostic method are presented. Select results from the measurements and interpretation are presented which will help guide future work.
Preparation of Permanent Mold Coating Using Magnesia Powder for Magnesium Alloys
NASA Astrophysics Data System (ADS)
Guo, Guangsi; Wang, Guangtai; Yu, Haifeng; Ye, Sheng
A kind of permanent mold coating for magnesium alloy was developed using magnesia powder and diatomite as refractory aggregate. The properties of the coating were tested and analyzed by various ingredients. The final ingredient was determined through the tests which are to find out the optimal proportion of two kinds of aggregate and the influences to coating properties by changing the proportion of binder and suspending agents. The experimental results shown that the permanent mold coating performed good properties on magnesium alloys when the optimized ratio of magnesia powder and diatomite was 6: 4, and the integrated property is very excellent when the coating was prepared with 2 percent of sodium bentonite, 0.4 percent of CMC, 7 percent of sodium hexametaphosphate, and 7 percent of sodium silicate. The excellent performance has also been proved by actual casting test.
Buhr, T L; Young, A A; Barnette, H K; Minter, Z A; Kennihan, N L; Johnson, C A; Bohmke, M D; DePaola, M; Cora-Laó, M; Page, M A
2015-11-01
To develop test methods and evaluate survival of Bacillus anthracis ∆Sterne or Bacillus thuringiensis Al Hakam on materials contaminated with dirty spore preparations after exposure to hot, humid air using response surface modelling. Spores (>7 log10 ) were mixed with humic acid + spent sporulation medium (organic debris) or kaolin (dirt debris). Spore samples were then dried on five different test materials (wiring insulation, aircraft performance coating, anti-skid, polypropylene, and nylon). Inoculated materials were tested with 19 test combinations of temperature (55, 65, 75°C), relative humidity (70, 80, 90%) and time (1, 2, 3 days). The slowest spore inactivation kinetics was on nylon webbing and/or after addition of organic debris. Hot, humid air effectively decontaminates materials contaminated with dirty Bacillus spore preparations; debris and material interactions create complex decontamination kinetic patterns; and B. thuringiensis Al Hakam is a realistic surrogate for B. anthracis. Response surface models of hot, humid air decontamination were developed which may be used to select decontamination parameters for contamination scenarios including aircraft. Published 2015. This article is a U.S. Government work and is in the public domain in the USA.
Dehghannezhad, Ardeshir; Paknejad, Maliheh; Rasaee, Mohammad Javad; Omidfar, Kobra; Seyyed Ebrahimi, Shadi Sadat; Ghahremani, Hossein
2012-12-01
A simple, rapid competitive immunochromatography (ICG) strip test was developed to detect morphine in urine samples using a monoclonal antibody produced in-house and conjugated to gold nanoparticles. Hybridoma cells were cultured and the Amor-HK16 monoclonal antibody against morphine was obtained from the supernatant after purification by salting out and passing through a Protein G-Agarose affinity column. Morphine was obtained from morphine sulfate and a C6-hemisuccinate derivative of morphine was prepared, conjugated to bovine serum albumin, and immobilized to a nitrocellulose membrane as the test line. Goat anti-mouse antibody was used as a binder in the control line in the detection zone of the strip. Colloidal gold particles of diameter approximately 20 nm were prepared and conjugated to the monoclonal antibody. The detection limit of the test strip was found to be 2000 ng/mL of morphine in urine samples. Reliability was determined by performing the ICG test on 103 urine samples and comparing the results with those obtained by thin-layer chromatography. The sensitivity of the test was 100%, and the analysis time for the assay was approximately 5 min. The new ICG method was adequately sensitive and accurate for the rapid screening of morphine in urine.
Risks of musculoskeletal disorders among betel quid preparers in Taiwan.
Chang, Jer-Hao; Wu, Jyun-De; Chen, Chih-Yong; Sumd, Shih-Bin; Yin, Hsin-I; Hsu, Der-Jen
2014-04-01
Betel quid chewing is common in Taiwan. The work of betel quid preparers is characterized by long hours of static work, awkward working posture and highly repetitive hand/wrist motion. However, the musculoskeletal health of betel quid preparers receives very little attention. The Chinese version of the Standardized Nordic Musculoskeletal Questionnaire (NMQ) was administered, and electrogoniometers and electromyography were used in this cross-sectional study to characterize the hand/wrist motion of the subjects. Physical examinations on the thumbs and wrists of the subjects were conducted by means of Phalen's test and Finkelstein's test, respectively. Among the 225 participants, more than 95% attributed their musculoskeletal complaints to their work, and shoulder, neck, hand/wrist, and lower back discomfort were most frequently reported. More than 70% of the preparers did not seek medical treatment for their musculoskeletal problems. Based on the physical examination, 24% of the participants had suspected symptom of either carpal tunnel syndrome (CTS) or DeQuervain's tenosynovitis. The instrumental measurements indicated that betel quid preparation is characterized by extreme angle ranges and moderate repetition of wrist motion as well as low forceful exertion. This study concludes that betel quid preparers are a high risk group of developing musculoskeletal disorders (MSDs). Future studies by electrogoniometers and detailed physical examination on betel quid preparers are needed to determine the predisposing factors for CTS. Some intervention measures to prevent MSDs and to lessen psychological stress for this group of workers are strongly suggested. © 2014 Wiley Periodicals, Inc.
A new ex vivo method for the study of nasal drops on ciliary function.
Levrier, J; Molon-Noblot, S; Duval, D; Lloyd, K G
1989-01-01
Any pharmaceutical nasal preparation should respect the physiological function of the mucociliary transport system and should undergo testing to this effect. An experimental protocol has been developed using the guinea pig in order to assess the effects of commercial nasal drop preparations on mucociliary function. The method presented here consists of applying in vivo the test solution on the nasal respiratory epithelium. After a specified contact time and following rapid sacrifice of the animal, the mucosa is removed; the beating frequency of the cilia is then recorded ex vivo by micro-photo-oscillography. The method is sensitive to compounds known to diminish mucociliary function as sodium mercurothiolate inhibits ciliary movement of the nasal epithelium ex vivo. This inhibition of ciliary movement is long-lasting, although reversible. This method can be used to test the action of intranasally administered pharmaceutical preparations on mucociliary function. Commercially available solutions of the nasal vasoconstrictors tymazoline, fenoxazoline or oxymetazoline do not alter ciliary movement ex vivo at dose levels equal to or greater than those clinically utilized. ATP significantly enhances nasal ciliary frequency in instances where a low basal rate occurred. Thus, this method can be used for the testing of the maintenance of nasal ciliary function in the presence of compounds and preparations which will be applied into the nostrils. The advantages over previous techniques include a closer approach to the therapeutic utilization and the maintained physiological conditions of the mucosa during drug administration.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brown, Geoffrey Wayne
2016-03-16
This document identifies scope and some general procedural steps for performing Remediated Nitrate Salt (RNS) Surrogate Formulation and Testing. This Test Plan describes the requirements, responsibilities, and process for preparing and testing a range of chemical surrogates intended to mimic the energetic response of waste created during processing of legacy nitrate salts. The surrogates developed are expected to bound1 the thermal and mechanical sensitivity of such waste, allowing for the development of process parameters required to minimize the risk to worker and public when processing this waste. Such parameters will be based on the worst-case kinetic parameters as derived frommore » APTAC measurements as well as the development of controls to mitigate sensitivities that may exist due to friction, impact, and spark. This Test Plan will define the scope and technical approach for activities that implement Quality Assurance requirements relevant to formulation and testing.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Jy-An John; Jiang, Hao
2016-01-12
To determine the tensile properties of irradiated fuel cladding in a hot cell, a simple test was developed at the Oak Ridge National Laboratory (ORNL) and is described fully in US Patent Application 20060070455, “Expanded plug method for developing circumferential mechanical properties of tubular materials.” This method is designed for testing fuel rod cladding ductility in a hot cell using an expandable plug to stretch a small ring of irradiated cladding material. The specimen strain is determined using the measured diametrical expansion of the ring. This method removes many complexities associated with specimen preparation and testing. The advantages are themore » simplicity of measuring the test component assembly in the hot cell and the direct measurement of the specimen’s strain. It was also found that cladding strength could be determined from the test results.« less
NASA Technical Reports Server (NTRS)
Krause, David L.; Brewer, Ethan J.; Pawlik, Ralph
2013-01-01
This report provides test methodology details and qualitative results for the first structural benchmark creep test of an Advanced Stirling Convertor (ASC) heater head of ASC-E2 design heritage. The test article was recovered from a flight-like Microcast MarM-247 heater head specimen previously used in helium permeability testing. The test article was utilized for benchmark creep test rig preparation, wall thickness and diametral laser scan hardware metrological developments, and induction heater custom coil experiments. In addition, a benchmark creep test was performed, terminated after one week when through-thickness cracks propagated at thermocouple weld locations. Following this, it was used to develop a unique temperature measurement methodology using contact thermocouples, thereby enabling future benchmark testing to be performed without the use of conventional welded thermocouples, proven problematic for the alloy. This report includes an overview of heater head structural benchmark creep testing, the origin of this particular test article, test configuration developments accomplished using the test article, creep predictions for its benchmark creep test, qualitative structural benchmark creep test results, and a short summary.
Ravikumar, Sundaram; Ramanathan, Ganesan; Inbaneson, Samuel Jacob; Ramu, Andy
2011-01-01
The ocean covers more than 70% of earth surface and hosts most 300,000 described species of plants and animals to use, which have been virtually unexploited for the development of medicines. Marine plants are the good source of biologically active entities which exhibit therapeutic properties, when applied single or in combination of different plant extracts (polyherbal). Polyherbal preparations are always a complex mixture of different forms and thus different compounds, which might act as agonistic, synergistic, complementary, antagonistic or toxic way. The present study was initially carried out to test the antiplasmodial activity of 13 mangrove plants and eight seaweeds species distributed along the coast of south India. Of these, mangrove species Aegiceras corniculatum and the seaweed species Chaetomorpha antennina have shown maximum antiplasmodial activity. Hence, the present study was mooted out to increase the percentage of antiplasmodial activity when applied as polyherbal preparations. The effect of marine polyherbal preparations from the methanolic extracts of two marine plants A. corniculatum and C. antennina for their antiplasmodial activity was tested. It shows that the polyherbal extract showed 63.50 ± 0.408% suppression of parasitaemia against Plasmodium falciparum at 1.5 mg ml⁻¹ concentration. In vivo test was carried out with rat animal model to find out the effectiveness of the polyherbal extracts in the live system, which reveals that polyherbal extracts have exhibited remarkable antiplasmodial activity (50.57 ± 0.465%) against Plasmodium berghei at 120 mg kg⁻¹ bw. This study shows that combinations of mangrove plants and seaweeds extracts had a source of lead compounds for the development of new drugs for the treatment of malaria.
Mehta, Sanjay R; MacGruder, Cathy; Looney, David; Johns, Scott; Smith, Davey M
2009-04-01
In response to a difference in pricing, the San Diego Veterans Administration Medical Center changed its tuberculin preparation from Tubersol to Aplisol in the fall of 2006. Following the change, an increased number of employee skin test conversions was noted. Employee tuberculin skin test converters from 2006 were screened with the QuantiFERON Gold (QFT-G) gamma interferon release assay. Those employees who tested negative by QFT-G were asked to repeat their skin test with both Tubersol and Aplisol tuberculin preparations. Of the new purified protein derivative converters, 12 of 14 returned for repeat testing with QFT-G, and the assay was negative for 83% (10/12), positive for 8% (1/12), and indeterminate for 8% (1/12) of the individuals. Nine of the individuals who were QFT-G negative agreed to repeat skin testing with both tuberculin preparations, and 7/8 (87.5%) demonstrated reactivity with the Aplisol preparation, while 0/8 (0%) reacted to the Tubersol preparation. A change from Tubersol to Aplisol resulted in elevated tuberculin skin test conversion rates that may be due to false-positive reactions. The differences in skin test reactivity between preparations support CDC guidelines that recommend that institutions should not change tuberculin preparations, as doing so may falsely increase the number of positive reactions.
40 CFR 86.1910 - How must I prepare and test my in-use engines?
Code of Federal Regulations, 2014 CFR
2014-07-01
.... In this case, only the post-repair test results would be used in the vehicle-pass determination as... 40 Protection of Environment 19 2014-07-01 2014-07-01 false How must I prepare and test my in-use... In-Use Testing Program for Heavy-Duty Diesel Engines § 86.1910 How must I prepare and test my in-use...
[Microfungicid--a preparation based on trichoderma viride for plant diseases control].
Kolombet, L V; Zhigletsova, S K; Derbyshev, V V; Ezhov, D V; Kosareva, N I; Bystrova, E V
2001-01-01
A technology was designed for manufacturing a preparation based on Trichoderma viride Pers ex S.F. Gray that strongly suppresses the development of causative agents of certain plant diseases and displays a growth-stimulating activity. Cultivation of the strain in a liquid medium for 18-24 h produced up to 60 g dry biomass per liter nutrient medium. A marketable form created in this work conserves the activity of the mycelial preparation for six months. The preparation is compatible with insecticides (carbofos, vismetrin, talstar, and applaud) and certain fungicides (such as baitan). Tests performed with the liquid form of Mycofungicid (seeds were treated with this preparation at a dose of 20-30 g per metric ton before sowing) showed its high efficiency in protecting cereal crops from plant pathogens. The incidence of plant diseases decreased by 65%, and crop yields increased by 15-20%.
[Comparison of the Conventional Centrifuged and Filtrated Preparations in Urine Cytology].
Sekita, Nobuyuki; Shimosakai, Hirofumi; Nishikawa, Rika; Sato, Hiroaki; Kouno, Hiroyoshi; Fujimura, Masaaki; Mikami, Kazuo
2016-03-01
The urine cytology test is one of the most important tools for the diagnosis of malignant urinary tract tumors. This test is also of great value for predicting malignancy. However, the sensitivity of this test is not high enough to screen for malignant cells. In our laboratory, we were able to attain a high sensitivity of urine cytology tests after changing the preparation method of urine samples. The differences in the cytodiagnosis between the two methods are discussed here. From January 2012 to June 2013, 2,031 urine samples were prepared using the conventional centrifuge method (C method) ; and from September 2013 to March 2015, 2,453 urine samples were prepared using the filtration method (F method) for the cytology test. When the samples included in category 4 or 5, were defined as cytological positive, the sensitivities of this test with samples prepared using the F method were significantly high compared with samples prepared using the C method (72% vs 28%, p<0.001). The number of cells on the glass slides prepared by the F method was significantly higher than that of the samples prepared by the C method (p<0.001). After introduction of the F method, the number of f alse negative cases was decreased in the urine cytology test because a larger number of cells was seen and easily detected as atypical or malignant epithelial cells. Therefore, this method has a higher sensitivity than the conventional C method as the sensitivity of urine cytology tests relies partially on the number of cells visualized in the prepared samples.
Optical Navigation Preparations for New Horizons Pluto Flyby
NASA Technical Reports Server (NTRS)
Owen, William M., Jr.; Dumont, Philip J.; Jackman, Coralie D.
2012-01-01
The New Horizons spacecraft will encounter Pluto and its satellites in July 2015. As was the case for the Voyager encounters with Jupiter, Saturn, Uranus and Neptune, mission success will depend heavily on accurate spacecraft navigation, and accurate navigation will be impossible without the use of pictures of the Pluto system taken by the onboard cameras. We describe the preparations made by the New Horizons optical navigators: picture planning, image processing algorithms, software development and testing, and results from in-flight imaging.
Multiple pulse nanosecond laser induced damage threshold on hybrid mirrors
NASA Astrophysics Data System (ADS)
Vanda, Jan; Muresan, Mihai-George; Bilek, Vojtech; Sebek, Matej; Hanus, Martin; Lucianetti, Antonio; Rostohar, Danijela; Mocek, Tomas; Škoda, Václav
2017-11-01
So-called hybrid mirrors, consisting of broadband metallic surface coated with dielectric reflector designed for specific wavelength, becoming more important with progressing development of broadband mid-IR sources realized using parametric down conversion system. Multiple pulse nanosecond laser induced damage on such mirrors was tested by method s-on-1, where s stands for various numbers of pulses. We show difference in damage threshold between common protected silver mirrors and hybrid silver mirrors prepared by PVD technique and their variants prepared by IAD. Keywords: LIDT,
Cho, JeongHyeon; Lee, SeungHee; Shin, Jung A; Kim, Jeong Ho; Lee, Hong Sub
2017-09-01
Few studies have evaluated the use of a smartphone application (app) for educating people undergoing colonoscopy and optimizing bowel preparation. Therefore, this study was designed to develop a smartphone app for people to use as a preparation guide and to evaluate the efficacy of this app when used prior to colonoscopy. In total, 142 patients (male:female=84:58, mean age=43.5±9.3 years), who were scheduled to undergo a colonoscopy at Myongji Hospital, were enrolled in this study. Seventy-one patients were asked to use a smartphone app that we had recently developed to prepare for the colonoscopy, while the 71 patients of the sex and age-matched control group were educated via written and verbal instructions. The quality of bowel cleansing, evaluated using the Boston Bowel Preparation Scale, was significantly higher in the smartphone app group than in the control group (7.70±1.1 vs. 7.24±0.8, respectively, p =0.007 by t -test). No significant differences were found between the two groups regarding work-up time and the number of patients with polyps. In this study, targeting young adults (≤50 years), the bowel preparation achieved by patients using the smartphone app showed significantly better quality than that of the control group.
Characterization of the Tribological Behavior of Oxide-Based NanoMaterials: Final CRADA Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fenske, George
2017-01-04
Under the Argonne/Pixelligent cooperative research and development agreement (CRADA – C1200801), Argonne performed labscale tribological tests on proprietary nano-sized ZrO 2 material developed by Pixelligent. Pixelligent utilized their proprietary process to prepare variants with different surfactants at different loadings in different carrier fluids for testing and evaluation at Argonne. Argonne applied a range of benchtop tribological test rigs to evaluate friction and wear under a range of conditions (contact geometry, loads, speeds, and temperature) that simulated a broad range of conditions experienced in engines and driveline components. Post-test analysis of worn surfaces provided information on the structure and chemistry ofmore » the tribofilms produced during the tests.« less
NASA Technical Reports Server (NTRS)
Gaines, G. B.; Thomas, R. E.; Noel, G. T.; Shilliday, T. S.; Wood, V. E.; Carmichael, D. C.
1979-01-01
Potential long-term degradation modes for the two types of modules in the Mead array were determined and judgments were made as to those environmental stresses and combinations of stresses which accelerate the degradation of the power output. Hierarchical trees representing the severity of effects of stresses (test conditions) on eleven individual degradation modes were constructed and were pruned of tests judged to be nonessential. Composites of those trees were developed so that there is now one pruned tree covering eight degradation modes, another covering two degradation modes, and a third covering one degradation mode. These three composite trees form the basis for selection of test conditions in the final test plan which is now being prepared.
NASA Technical Reports Server (NTRS)
Hutchens, Dale E.; Doan, Patrick A.; Boothe, Richard E.
1997-01-01
Bonding labs at both MSFC and the northern Utah production plant prepare bond test specimens which simulate or witness the production of NASA's Reusable Solid Rocket Motor (RSRM). The current process for preparing the bonding surfaces employs 1,1,1-trichloroethane vapor degreasing, which simulates the current RSRM process. Government regulations (e.g., the 1990 Amendments to the Clean Air Act) have mandated a production phase-out of a number of ozone depleting compounds (ODC) including 1,1,1-trichloroethane. In order to comply with these regulations, the RSRM Program is qualifying a spray-in-air (SIA) precision cleaning process using Brulin 1990, an aqueous blend of surfactants. Accordingly, surface preparation prior to bonding process simulation test specimens must reflect the new production cleaning process. The Bonding Lab Statistical Process Control (SPC) program monitors the progress of the lab and its capabilities, as well as certifies the bonding technicians, by periodically preparing D6AC steel tensile adhesion panels with EA-91 3NA epoxy adhesive using a standardized process. SPC methods are then used to ensure the process is statistically in control, thus producing reliable data for bonding studies, and identify any problems which might develop. Since the specimen cleaning process is being changed, new SPC limits must be established. This report summarizes side-by-side testing of D6AC steel tensile adhesion witness panels and tapered double cantilevered beams (TDCBs) using both the current baseline vapor degreasing process and a lab-scale spray-in-air process. A Proceco 26 inches Typhoon dishwasher cleaned both tensile adhesion witness panels and TDCBs in a process which simulates the new production process. The tests were performed six times during 1995, subsequent statistical analysis of the data established new upper control limits (UCL) and lower control limits (LCL). The data also demonstrated that the new process was equivalent to the vapor degreasing process.
Abstracts from the Research and Development Report Series, 1963-81. College Board Report No. 82-1.
ERIC Educational Resources Information Center
Hendel, Patricia K., Ed.
A compilation of 109 abstracts from the "Research and Development Report Series," is presented based on R&D projects conducted during 1963-1981 by Educational Testing Service on behalf of the College Entrance Examination Board. Project titles and authors include the following: "The Effect of Special Preparation on SAT Verbal…
Microfluidic Sample Preparation for Diagnostic Cytopathology
Mach, Albert J.; Adeyiga, Oladunni B.; Di Carlo, Dino
2014-01-01
The cellular components of body fluids are routinely analyzed to identify disease and treatment approaches. While significant focus has been placed on developing cell analysis technologies, tools to automate the preparation of cellular specimens have been more limited, especially for body fluids beyond blood. Preparation steps include separating, concentrating, and exposing cells to reagents. Sample preparation continues to be routinely performed off-chip by technicians, preventing cell-based point-of-care diagnostics, increasing the cost of tests, and reducing the consistency of the final analysis following multiple manually-performed steps. Here, we review the assortment of biofluids for which suspended cells are analyzed, along with their characteristics and diagnostic value. We present an overview of the conventional sample preparation processes for cytological diagnosis. We finally discuss the challenges and opportunities in developing microfluidic devices for the purpose of automating or miniaturizing these processes, with particular emphases on preparing large or small volume samples, working with samples of high cellularity, automating multi-step processes, and obtaining high purity subpopulations of cells. We hope to convey the importance of and help identify new research directions addressing the vast biological and clinical applications in preparing and analyzing the array of available biological fluids. Successfully addressing the challenges described in this review can lead to inexpensive systems to improve diagnostic accuracy while simultaneously reducing overall systemic healthcare costs. PMID:23380972
Test Preparation Beliefs and Practices in a High-Stakes Context: A Teacher's Perspective
ERIC Educational Resources Information Center
Gebril, Atta; Eid, Michael
2017-01-01
Policy makers worldwide are increasingly using high-stakes tests for accountability purposes. This practice has resulted in a considerable rise in test preparation activities in different instructional contexts. The purpose of this study is to investigate teachers' test preparation beliefs and practices in a high-stakes assessment context in…
40 CFR 1066.407 - Vehicle preparation and preconditioning.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 34 2012-07-01 2012-07-01 false Vehicle preparation and...) AIR POLLUTION CONTROLS VEHICLE-TESTING PROCEDURES Vehicle Preparation and Running a Test § 1066.407 Vehicle preparation and preconditioning. This section describes steps to take before measuring exhaust...
40 CFR 1066.407 - Vehicle preparation and preconditioning.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 34 2013-07-01 2013-07-01 false Vehicle preparation and...) AIR POLLUTION CONTROLS VEHICLE-TESTING PROCEDURES Vehicle Preparation and Running a Test § 1066.407 Vehicle preparation and preconditioning. This section describes steps to take before measuring exhaust...
Niedermann, K; Forster, A; Hammond, A; Uebelhart, D; de Bie, R
2007-03-15
Joint protection (JP) is an important part of the treatment concept for patients with rheumatoid arthritis (RA). The Joint Protection Behavior Assessment short form (JPBA-S) assesses the use of hand JP methods by patients with RA while preparing a hot drink. The purpose of this study was to develop a German version of the JPBA-S (D-JPBA-S) and to test its validity and reliability. A manual was developed through consensus with 8 occupational therapist (OT) experts as the reference for assessing patients' JP behavior. Twenty-four patients with RA and 10 healthy individuals were videotaped while performing 10 tasks reflecting the activity of preparing instant coffee. Recordings were repeated after 3 months for test-retest analysis. One rater assessed all available patient recordings (n = 23, recorded twice) for test-retest reliability. The video recordings of 10 randomly selected patients and all healthy individuals were independently assessed for interrater reliability by 6 OTs who were explicitly asked to follow the manual. Rasch analysis was performed to test construct validity and transform ordinal raw data into interval data for reliability calculations. Nine of the 10 tasks fit the Rasch model. The D-JPBA-S, consisting of 9 valid tasks, had an intraclass correlation coefficient of 0.77 for interrater reliability and 0.71 for test-retest reliability. The D-JPBA-S provides a valid and reliable instrument for assessing JP behavior of patients with RA and can be used in German-speaking countries.
ERIC Educational Resources Information Center
Brown, Dorothy F.
1988-01-01
A discussion of vocabulary development for intermediate and advanced students preparing for the Australian certification test for Teaching English as a Foreign Language focuses on nine areas: collocations, clines, clusters, cloze procedures, context, consultation or checking, cards, creativity, and guessing. (seven references) (LB)
DOT National Transportation Integrated Search
2015-02-01
This Demonstration Team Final Report has been prepared to provide an overview of the conduct and qualitative findings of the LA-Gateway FRATIS development and testing program. More specifically, this document provides: A description of the testin...
South Florida freight advanced traveler information system : demonstration team final report.
DOT National Transportation Integrated Search
2015-05-01
This Demonstration Team Final Report has been prepared to provide an overview of the conduct and qualitative findings of the South Florida FRATIS development and testing program. More specifically, this document provides: A description of the tes...
NASA Astrophysics Data System (ADS)
Doser, D. I.
2009-12-01
We have designed a workshop breakout session and accompanying web based materials to assist geoscience departments in better preparing their students for professional careers following graduation. The session explores ways to obtain feedback about career preparation from employers and alumni that can be used to develop more effective curriculum, as well as departmental activities to better prepare students for employment opportunities. In addition, it identifies sources outside a department that can be used in the workforce preparation process and methods to assess any changes implemented to prepare students for the workforce. Concrete examples include feedback from a survey of recent (< 5 years) alumni at the University of Texas at El Paso, student run research meetings with built-in assessment opportunities, and a wealth of on-line resources. The session was initially tested in June 2009 at the Strengthening Your Strong Geoscience Department workshop. Comments from the June participants have been used to improve the session for the 2009-2010 “visiting workshop” program.
Guidebook for Developing Criterion-Referenced Tests
1975-08-01
struction (each student learning at his own pace ), and then tested when he felt prepared to take the test. Note that an NRT is des 4 grea to spread people out...be able to build a CRT. A properly constructed CRT will allow you to classify the people who take it into two groups: , Masters--those who you are...Instructioial Objectives * Instructional Goals e Learning Objectives 9 Terminal Training Objectives This level describes work activities which can stand by
Evaluation of Dipsol IZ-C17 LHE Zinc-Nickel Plating (Briefing Charts)
2007-01-24
Results • Based on Successful Test Results an LHE Alkaline Zn-Ni Formula was Selected for Further Development – Identified as Dipsol IZ-C17 (13 to...Hydrogen Embrittlement Test Methods • Select Repair Procedures 16. ENVIRONMENTAL ASSURANCE 2006 Status • IZ-C17 Tech Bulletin (Draft) Prepared...Corrosion Testing (Salt Spray and Galvanic) – Fluid Immersion (ASTM F 483) – Lubricity (Fasteners) – Strippability (BCA – Ammonium Nitrate pH 10) – Throwing
NASA Ames Contributes to Orion / EFT-1 Test Flight (Reporter Pkg)
2014-12-03
NASA's Orion spacecraft is built to take humans farther than they've ever gone before. Orion will serve as the exploration vehicle that will carry the crew to space, provide emergency abort capability, sustain the crew during the space travel, and provide safe re-entry from deep space return velocities. NASA's Ames Research Center played a critical role in the development and preparation for the flight test designated Exploration Flight Test 1, or EFT-1.
Hartmann, Nanna B; Jensen, Keld Alstrup; Baun, Anders; Rasmussen, Kirsten; Rauscher, Hubert; Tantra, Ratna; Cupi, Denisa; Gilliland, Douglas; Pianella, Francesca; Riego Sintes, Juan M
2015-01-01
Selecting appropriate ways of bringing engineered nanoparticles (ENP) into aqueous dispersion is a main obstacle for testing, and thus for understanding and evaluating, their potential adverse effects to the environment and human health. Using different methods to prepare (stock) dispersions of the same ENP may be a source of variation in the toxicity measured. Harmonization and standardization of dispersion methods applied in mammalian and ecotoxicity testing are needed to ensure a comparable data quality and to minimize test artifacts produced by modifications of ENP during the dispersion preparation process. Such harmonization and standardization will also enhance comparability among tests, labs, and studies on different types of ENP. The scope of this review was to critically discuss the essential parameters in dispersion protocols for ENP. The parameters are identified from individual scientific studies and from consensus reached in larger scale research projects and international organizations. A step-wise approach is proposed to develop tailored dispersion protocols for ecotoxicological and mammalian toxicological testing of ENP. The recommendations of this analysis may serve as a guide to researchers, companies, and regulators when selecting, developing, and evaluating the appropriateness of dispersion methods applied in mammalian and ecotoxicity testing. However, additional experimentation is needed to further document the protocol parameters and investigate to what extent different stock dispersion methods affect ecotoxicological and mammalian toxicological responses of ENP.
High power cable with internal water cooling 400 kV
NASA Astrophysics Data System (ADS)
Rasquin, W.; Harjes, B.
1982-08-01
Due to the concentration of electricity production in large power plants, the need of higher power transmissions, and the protection of environment, developement of a 400 kV water cooled cable in the power range of 1 to 5 GVA was undertaken. The fabrication and testing of equipment, engineering of cable components, fabrication of a test cable, development of cable terminal laboratory, testing of test cable, field testing of test cable, fabrication of industrial cable laboratory, testing of industrial cable, field testing of industrial cable, and system analysis for optimization were prepared. The field testing was impossible to realize. However, it is proved that a cable consisting of an internal stainless steel water cooled tube, covered by stranded copper profiles, insulated with heavy high quality paper, and protected by an aluminum cover can be produced, withstand tests accordingly to IEC/VDE recommendations, and is able to fulfill all exploitation conditions.
ERIC Educational Resources Information Center
Bachman, Tori Mello
Parents can help their children prepare for reading tests in a number of ways, not only just before the test, but also with everyday activities. There are generally two types of reading tests given to students: tests given by teachers throughout the year to see what information students have retained, and more formal, often standardized, tests…
ERIC Educational Resources Information Center
Ting, Mu Yu
2017-01-01
Using the capabilities of expert knowledge structures, the researcher prepared test questions on the university calculus topic of "finding the area by integration." The quiz is divided into two types of multiple choice items (one out of four and one out of many). After the calculus course was taught and tested, the results revealed that…
Acquisition Community Team Dynamics: The Tuckman Model vs. the DAU Model
2007-04-30
courses . These student teams are used to enable the generation of more complex products and to prepare the students for the ...requirement for stage discreteness was met, I developed a stage-separation test that, when applied to the data representing the experience of a... test the reliability, and validate an improved questionnaire instrument that: – Redefines “Storming” with new storming questions Less focused
ERIC Educational Resources Information Center
Hassan Seifeddin, Ahmed; Zakareya Ahmed, Samah; Yahia Mohammed Ebrahim, Eman
2015-01-01
This study aimed to investigate the effect of a program based on English digital stories on second-year preparatory pupils' writing performance and reflective thinking. Two writing performance tests (pretest and posttest) as well as a reflective thinking test were prepared by the researchers. Two 2nd-year intact classes from El Sadat Prep School…
Balloon-borne 3-meter telescope for far-infrared and submillimeter astronomy
NASA Technical Reports Server (NTRS)
Fazio, G. G.
1986-01-01
The gimbal design was studied and revised to eliminate the alignment and limited rotation problems inherent in the flex-pivot design. A new design using ball-bearings to replace the flex-pivot was defined and its performance analyzed. An error analysis for the entire gondola pointing system was also prepared. Mirror development and the test program using mirror test blanks from Dornier were continued.
[Troubleshooting of bioinequivalence of compound valsartan tablets].
Shao, Da; Zhang, Yi-Fan; Zhan, Yan; Chen, Xiao-Yan; Zhong, Da-Fang
2014-04-01
The study aims to evaluate the bioequivalence of valsartan hydrochlorothiazide tablets, and to investigate the potential cause of bioinequivalence. This was a single-center study with an open, randomized double-way crossover design. Test and reference preparations containing 160 mg of valsartan and 25 mg of hydrochlorothiazide were given to 36 healthy male volunteers. Plasma concentrations of valsartan and hydrochlorothiazide were determined simultaneously by LC-MS/MS. The pharmacokinetic parameters and relative bioavailability were calculated, while the bioequivalence between test and reference preparations were evaluated. The dissolution profiles of test and reference preparations in four different mediums were determined via dissolution test and HPLC. The similarity was investigated according to the similarity factors (f2). The F(o-t) and F(0-infinity) were (139.4 +/- 65.2)% and (137.5 +/- 61.2)% for valsartan of test preparations. It led to get the conclusion that test and reference preparations were not bioequivalent for valsartan. A significant difference was observed between test and reference tablets in the valsartan dissolution test of pH 1.2 hydrochloric acid solution. The key factor of the bioinequivalence might be that dissolution of valsartan in acid medium has marked difference between two preparations.
2013-12-06
CAPE CANAVERAL, Fla. – At NASA’s Kennedy Space Center in Florida, the Project Morpheus prototype lander is being prepared for placement on a transportable launch platform positioned at the north end of the Shuttle Landing Facility. The lander will be prepared for a tethered test that includes lifting it 20 feet by crane, ascending another 10 feet, maneuvering backwards 10 feet, and then flying forward and descending to its original position, landing at the end of the tether. Testing of the prototype lander was performed at NASA’s Johnson Space Center in Houston in preparation for tethered and free flight testing at Kennedy. The landing facility will provide the lander with the kind of field necessary for realistic testing, complete with rocks, craters and hazards to avoid. Morpheus utilizes an autonomous landing and hazard avoidance technology, or ALHAT, payload that will allow it to navigate to clear landing sites amidst rocks, craters and other hazards during its descent. Project Morpheus is being managed under the Advanced Exploration Systems, or AES, Division in NASA’s Human Exploration and Operations Mission Directorate. The efforts in AES pioneer new approaches for rapidly developing prototype systems, demonstrating key capabilities and validating operational concepts for future human missions beyond Earth orbit. For more information on Project Morpheus, visit http://morpheuslander.jsc.nasa.gov. Photo credit: NASA/Kim Shiflett
40 CFR 86.131-96 - Vehicle preparation.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Heavy-Duty Vehicles; Test Procedures § 86.131-96 Vehicle preparation. (a) For gasoline- and methanol-fueled vehicles prepare the fuel tank(s) for recording the temperature of the prescribed test fuel, as... optional during the running loss test. If vapor temperature is not measured, fuel tank pressure need not be...
40 CFR 86.131-96 - Vehicle preparation.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Heavy-Duty Vehicles; Test Procedures § 86.131-96 Vehicle preparation. (a) For gasoline- and methanol-fueled vehicles prepare the fuel tank(s) for recording the temperature of the prescribed test fuel, as... optional during the running loss test. If vapor temperature is not measured, fuel tank pressure need not be...
40 CFR 86.131-96 - Vehicle preparation.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Heavy-Duty Vehicles; Test Procedures § 86.131-96 Vehicle preparation. (a) For gasoline- and methanol-fueled vehicles prepare the fuel tank(s) for recording the temperature of the prescribed test fuel, as... optional during the running loss test. If vapor temperature is not measured, fuel tank pressure need not be...
40 CFR 86.131-96 - Vehicle preparation.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Heavy-Duty Vehicles; Test Procedures § 86.131-96 Vehicle preparation. (a) For gasoline- and methanol-fueled vehicles prepare the fuel tank(s) for recording the temperature of the prescribed test fuel, as... optional during the running loss test. If vapor temperature is not measured, fuel tank pressure need not be...
40 CFR 86.131-96 - Vehicle preparation.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Heavy-Duty Vehicles; Test Procedures § 86.131-96 Vehicle preparation. (a) For gasoline- and methanol-fueled vehicles prepare the fuel tank(s) for recording the temperature of the prescribed test fuel, as... optional during the running loss test. If vapor temperature is not measured, fuel tank pressure need not be...
Ye, Yuanyuan; Deng, Yin; Mao, Jinju; Yan, Qin; Huang, Yidan; Zhang, Jun; Zheng, Jian; Li, Yue; Chen, Weixian
2018-05-01
Fecal occult bloodtest (FOBT) plays an important role in the diagnosis of gastrointestinal diseases. The sensitivities of current FOBT methods are still not satisfactory. The aim of this study is to develop a combined human transferrin (HTf)-hemoglobin (HHb) lateral flow assay (LFA) for accurate and rapid FOBT. Monoclonal antibodies (MAbs) targeting HTf were developed by conventional methods and paired using LFA strips. The best HTf MAb pair was chosen according to the overall performance on testing limit and specificity. Meanwhile, HHb LFA strips were prepared using previously developed HHb MAbs. The testing limit and specificity were characterized. Based on the selected HTf MAb pair and the verified HHb MAb pair, combined HTf-HHb strips were developed. The combined HTf-HHb strips were used for FOBT of 400 human fecal samples, including 200 gastrointestinal bleeding specimens and 200 healthy subjects. For comparison, the homemade individual HTf and HHb strips, as well as three kinds of commercial FOBT strips, were also used for the FOBT. Two MAb pairs targeting HTf were developed for LFA. Two types of HTf strips were prepared accordingly. The type I was chosen due to its lower detection limit. Using the type I HTf MAb pair and the verified HHb- MAb pair, the combined HTf-HHb strips could detect the HTf at concentrations between 1 ng/mL and 1 x 106 ng/mL and the HHb between 10 ng/mL and 2.5 x 106 ng/mL. Compared to individual HTf and HHb strips and three kinds of commercial strips, the combined strips showed the highest diagnostic sensitivity in FOBT (96.0%). The specificity was a satisfactory 99%. Our combined HTf-HHb test strips are a very promising product for accurate and rapid FOBT.
Characterization of LWRS Hybrid SiC-CMC-Zircaloy-4 Fuel Cladding after Gamma Irradiation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Isabella J van Rooyen
2012-09-01
The purpose of the gamma irradiation tests conducted at the Idaho National Laboratory (INL) was to obtain a better understanding of chemical interactions and potential changes in microstructural properties of a mock-up hybrid nuclear fuel cladding rodlet design (unfueled) in a simulated PWR water environment under irradiation conditions. The hybrid fuel rodlet design is being investigated under the Light Water Reactor Sustainability (LWRS) program for further development and testing of one of the possible advanced LWR nuclear fuel cladding designs. The gamma irradiation tests were performed in preparation for neutron irradiation tests planned for a silicon carbide (SiC) ceramic matrixmore » composite (CMC) zircaloy-4 (Zr-4) hybrid fuel rodlet that may be tested in the INL Advanced Test Reactor (ATR) if the design is selected for further development and testing« less
Resource Prospector Propulsion Cold Flow Test
NASA Technical Reports Server (NTRS)
Williams, Hunter; Pederson, Kevin; Dervan, Melanie; Holt, Kimberly; Jernigan, Frankie; Trinh, Huu; Flores, Sam
2014-01-01
For the past year, NASA Marshall Space Flight Center and Johnson Space Center have been working on a government version of a lunar lander design for the Resource Prospector Mission. A propulsion cold flow test system, representing an early flight design of the propulsion system, has been fabricated. The primary objective of the cold flow test is to simulate the Resource Prospector propulsion system operation through water flow testing and obtain data for anchoring analytical models. This effort will also provide an opportunity to develop a propulsion system mockup to examine hardware integration to a flight structure. This paper will report the work progress of the propulsion cold flow test system development and test preparation. At the time this paper is written, the initial waterhammer testing is underway. The initial assessment of the test data suggests that the results are as expected and have a similar trend with the pretest prediction. The test results will be reported in a future conference.
Akeroyd, Michael A; Arlinger, Stig; Bentler, Ruth A; Boothroyd, Arthur; Dillier, Norbert; Dreschler, Wouter A; Gagné, Jean-Pierre; Lutman, Mark; Wouters, Jan; Wong, Lena; Kollmeier, Birger
2015-01-01
To provide guidelines for the development of two types of closed-set speech-perception tests that can be applied and interpreted in the same way across languages. The guidelines cover the digit triplet and the matrix sentence tests that are most commonly used to test speech recognition in noise. They were developed by a working group on Multilingual Speech Tests of the International Collegium of Rehabilitative Audiology (ICRA). The recommendations are based on reviews of existing evaluations of the digit triplet and matrix tests as well as on the research experience of members of the ICRA Working Group. They represent the results of a consensus process. The resulting recommendations deal with: Test design and word selection; Talker characteristics; Audio recording and stimulus preparation; Masking noise; Test administration; and Test validation. By following these guidelines for the development of any new test of this kind, clinicians and researchers working in any language will be able to perform tests whose results can be compared and combined in cross-language studies.
Software development tools: A bibliography, appendix C.
NASA Technical Reports Server (NTRS)
Riddle, W. E.
1980-01-01
A bibliography containing approximately 200 citations on tools which help software developers perform some development task (such as text manipulation, testing, etc.), and which would not necessarily be found as part of a computing facility is given. The bibliography comes from a relatively random sampling of the literature and is not complete. But it is indicative of the nature and range of tools currently being prepared or currently available.
NASA Technical Reports Server (NTRS)
Mitchell, Sherry L.
2018-01-01
The Customer Avionics Interface Development and Analysis (CAIDA) supports the testing of the Launch Control System (LCS), NASA's command and control system for the Space Launch System (SLS), Orion Multi-Purpose Crew Vehicle (MPCV), and ground support equipment. The objective of the semester-long internship was to support day-to-day operations of CAIDA and help prepare for verification and validation of CAIDA software.
Bowel preparation for colonoscopy: state of the art.
Voiosu, Theodor; Voiosu, Andrei; Voiosu, Radu
2016-07-13
Bowel preparation for colonoscopy is a key quality indicator that impacts on all aspects of the procedure, such as patient comfort, diagnostic yield, and adverse events. Although most laxative regimens currently employed have been compared in a multitude of settings, the optimal preparation regimen still remains an open question. Recent studies have focused on developing new regimens by modifying dosage, timing of administration or by combining laxatives with synergic mechanisms of action with the purpose of increasing patient tolerability while maximizing bowel cleansing. Several low-volume preparations and combinations of laxatives and adjunctive medication have shown promise in delivering both adequate preparation of the colon and good patient tolerability. Also, we have gained a better understanding of the influence of patient-related factors such as health literacy and education on the quality of bowel preparation. Although several novel regimens have been tested in recent trials, it remains unclear which, if any, of these bowel preparations can replace the standard bowel cleansing regimens in clinical practice. Also, further data are required on how to improve bowel cleansing by choosing the appropriate regimen for the individual patient.
Salama, R; Sattayasai, J; Gande, A K; Sattayasai, N; Davis, M; Lattmann, E
2012-02-01
The aim of this study was firstly to identify active molecules in herbs, that are traditionally used for the treatment of snake bite, such as Curcuma antinaia, Curcuma contravenenum, Andrographis paniculata, and Tanacetum parthenium; secondly to test similar structurally related molecules and finally to prepare and evaluate an efficient formulation against Ophiophagus hannah venom intoxification. Three labdane based compounds, including labdane dialdehyde, labdane lactone, and labdane trialdehyde and two lactones including 14-deoxy-11,12-didehydroandrographolide and parthenolide were isolated by column chromatography and characterised. Using the isolated rat phrenic nerve-hemidiaphragm preparation, the antagonistic effect of crude extracts, isolated compounds and prepared formulations were measured in vitro on the inhibition of the neuromuscular transmission. Inhibition on muscle contraction, produced by the 5 μg/mL venom, was reversed by test agents in organ bath preparations. A labdane trialdehyde, isolated from C. contravenenum, was identified as the best antagonising agent in the low micromolar range. Tests on formulations of the most potent C. contravenenum extract showed, that the suppository with witepsol H15 was an effective medicine against O. hannah venom. This study elucidated the active compounds, accounting for the antivenin activity of traditionally used herbs and suggested the most suitable formulation, which may help to develop potent medicines for the treatment of snake bite in the future.
On-board processing for telecommunications satellites
NASA Technical Reports Server (NTRS)
Nuspl, P. P.; Dong, G.
1991-01-01
In this decade, communications satellite systems will probably face dramatic challenges from alternative transmission means. To balance and overcome such competition, and to prepare for new requirements, INTELSAT has developed several on-board processing techniques, including Satellite-Switched TDMA (SS-TDMA), Satellite-Switched FDMA (SS-FDMA), several Modulators/Demodulators (Modem), a Multicarrier Multiplexer and Demodulator MCDD), an International Business Service (IBS)/Intermediate Data Rate (IDR) BaseBand Processor (BBP), etc. Some proof-of-concept hardware and software were developed, and tested recently in the INTELSAT Technical Laboratories. These techniques and some test results are discussed.
Development and evaluation of novel lozenges containing marshmallow root extract.
Benbassat, Niko; Kostova, Bistra; Nikolova, Irina; Rachev, Dimitar
2013-11-01
Lozenges (tablets intended to be dissolved slowly in the mouth) were evaluated as delivery system for polysaccharides extract from Althaea officinalis L. (marshmallow) root. The aim of investigation was to improve of the efficacy of convenient preparations for the treatment of irritated oropharyngeal mucosa and associated dry irritable cough. The formulations studied were prepared with water extract of roots of Althaea officinalis L. The polysaccharides extract was obtained by ultrasonification. Acute oral toxicity (LD 50 p.o.) of the obtained extract was estimated in mice. Four models of lozenges based on different excipients were formulated. The characteristics of the preparations: resistance to crushing, friability testing, disintegration time and drug release properties were evaluated.
Space Station Furnace Facility. Volume 2: Requirements definition and conceptual design study
NASA Technical Reports Server (NTRS)
1992-01-01
The Space Station Freedom Furnace (SSFF) Project is divided into two phases: phase 1, a definition study phase, and phase 2, a design and development phase. TBE was awarded a research study entitled, 'Space Station Furnace Facility Requirements Definition and Conceptual Design Study' on June 2, 1989. This report addresses the definition study phase only. Phase 2 is to be complete after completion of phase 1. The contract encompassed a requirements definition study and culminated in hardware/facility conceptual designs and hardware demonstration development models to test these conceptual designs. The study was divided into two parts. Part 1 (the basic part of the effort) encompassed preliminary requirements definition and assessment; conceptional design of the SSFF Core; fabrication of mockups; and preparation for the support of a conceptional design review (CoDR). Part 2 (the optional part of the effort) included detailed definition of the engineering and design requirements, as derived from the science requirements; refinement of the conceptual design of the SSFF Core; fabrication and testing of the 'breadboards' or development models; and preparation for and support of a requirements definition review.
Anti-Idling Battery for Truck Applications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Keith Kelly
2011-09-30
In accordance to the Assistance Agreement DE-EE0001036, the objective of this project was to develop an advanced high voltage lithium-ion battery for use in an all-electric HVAC system for Class-7-8 heavy duty trucks. This system will help heavy duty truck drivers meet the tough new anti-idling laws being implemented by over 23 states. Quallion will be partnering with a major OEM supplier of HVAC systems to develop this system. The major OEM supplier will provide Quallion the necessary interface requirements and HVAC hardware to ensure successful testing of the all-electric system. At the end of the program, Quallion will delivermore » test data on three (3) batteries as well as test data for the prototype HVAC system. The objectives of the program are: (1) Battery Development - Objective 1 - Define battery and electronics specifications in preparation for building the prototype module. (Completed - summary included in report) and Objective 2 - Establish a functional prototype battery and characterize three batteries in-house. (Completed - photos and data included in report); (2) HVAC Development - Objective 1 - Collaborate with manufacturers to define HVAC components, layout, and electronics in preparation for establishing the prototype system. (Completed - photos and data included in report) and Objective 2 - Acquire components for three functional prototypes for use by Quallion. (Completed - photos and data included in report).« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pippin, L.C.
The First Amendment to the United States Constitution guarantees the inherent right of all Americans to freedom of religion. However, since the religious practices of Native Americans are significantly different from those of the majority of Americans, their religious freedom has often restricted. Section 2 of the American Indian Religious Freedom Act (AIRFA) of 1978 (Public Law 95-341) directs federal agencies to consult with Native Americans to determine appropriate procedures to protect the inherent rights of Native Americans to believe, express, and exercise their traditional religions including, but not limited to access to sites, use and possession of sacred objects,more » and freedom to worship through ceremonials and traditional rites. The NTS AIRFA Compliance Program was initiated in October 1989 to assist DOE in expanding its compliance with AIRFA to incorporate all weapons testing activities on the NTS. It is directed at the development and implementation of a consultation plan designed to solicit, on behalf of DOE, Native American comments regarding the effects of the DOE's nuclear testing activities on historic properties of Native American origin and the expression and exercise of traditional Native American religions. The program has been developed around a phased approach that includes; (1) literature review and evaluation, (2) preparation of a baseline document, (3) preparation of a study design, (4) consultation with Native Americans, (5) preparation of a draft report, (6) Native American and State consultation and review, and (7) preparation of a final report.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pippin, L.C.
The First Amendment to the United States Constitution guarantees the inherent right of all Americans to freedom of religion. However, since the religious practices of Native Americans are significantly different from those of the majority of Americans, their religious freedom has often restricted. Section 2 of the American Indian Religious Freedom Act (AIRFA) of 1978 (Public Law 95-341) directs federal agencies to consult with Native Americans to determine appropriate procedures to protect the inherent rights of Native Americans to believe, express, and exercise their traditional religions including, but not limited to access to sites, use and possession of sacred objects,more » and freedom to worship through ceremonials and traditional rites. The NTS AIRFA Compliance Program was initiated in October 1989 to assist DOE in expanding its compliance with AIRFA to incorporate all weapons testing activities on the NTS. It is directed at the development and implementation of a consultation plan designed to solicit, on behalf of DOE, Native American comments regarding the effects of the DOE`s nuclear testing activities on historic properties of Native American origin and the expression and exercise of traditional Native American religions. The program has been developed around a phased approach that includes; (1) literature review and evaluation, (2) preparation of a baseline document, (3) preparation of a study design, (4) consultation with Native Americans, (5) preparation of a draft report, (6) Native American and State consultation and review, and (7) preparation of a final report.« less
How to Write Effective Procedure Manuals.
ERIC Educational Resources Information Center
Wold, Geoffrey H.
1987-01-01
Describes six key guidelines for developing usable procedure manuals, including defining the audience; designing a standard format; preparing an outline; using a clear, concise writing style; testing the procedures; and "finalizing" the product with indices, glossaries, appendices, and section tabs. Well-written manuals can increase…
Fitzgerald, T D
1993-03-01
Studies were conducted to determine the relative effectiveness of 5β-cholestane-3,24-dione (diketone) and 5β-cholestan-3-one (monoketone) in eliciting trail following from eastern tent caterpillars,Malacosoma americanum. In Y maze tests, trails prepared from the monoketone were followed preferentially over diketone trails, even when the diketone trail was several orders of magnitude stronger. Under field conditions, colonies readily abandoned well-developed trail systems in favor of artificial trails that were established with the monoketone. Other tests in which the caterpillars selected trails prepared from the monoketone (but not the diketone) more often than their own recruitment trails indicate that the monoketone constitutes the chemical basis of recruitment communication in this insect. The study also shows that tent caterpillars are highly sensitive to small differences in the amount of monoketone in a trail and can distinguish between new and aged trails prepared from the compound.
NASA Astrophysics Data System (ADS)
Chartosias, Marios
Acceptance of Carbon Fiber Reinforced Polymer (CFRP) structures requires a robust surface preparation method with improved process controls capable of ensuring high bond quality. Surface preparation in a production clean room environment prior to applying adhesive for bonding would minimize risk of contamination and reduce cost. Plasma treatment is a robust surface preparation process capable of being applied in a production clean room environment with process parameters that are easily controlled and documented. Repeatable and consistent processing is enabled through the development of a process parameter window utilizing techniques such as Design of Experiments (DOE) tailored to specific adhesive and substrate bonding applications. Insight from respective plasma treatment Original Equipment Manufacturers (OEMs) and screening tests determined critical process factors from non-factors and set the associated factor levels prior to execution of the DOE. Results from mode I Double Cantilever Beam (DCB) testing per ASTM D 5528 [1] standard and DOE statistical analysis software are used to produce a regression model and determine appropriate optimum settings for each factor.
Aerodynamic Tests of the Space Launch System for Database Development
NASA Technical Reports Server (NTRS)
Pritchett, Victor E.; Mayle, Melody N.; Blevins, John A.; Crosby, William A.; Purinton, David C.
2014-01-01
The Aerosciences Branch (EV33) at the George C. Marshall Space Flight Center (MSFC) has been responsible for a series of wind tunnel tests on the National Aeronautics and Space Administration's (NASA) Space Launch System (SLS) vehicles. The primary purpose of these tests was to obtain aerodynamic data during the ascent phase and establish databases that can be used by the Guidance, Navigation, and Mission Analysis Branch (EV42) for trajectory simulations. The paper describes the test particulars regarding models and measurements and the facilities used, as well as database preparations.
Preparing the optics technology to observe the hot universe
NASA Astrophysics Data System (ADS)
Bavdaz, Marcos; Wille, Eric; Wallace, Kotska; Shortt, Brian; Fransen, Sebastiaan; Collon, Maximilien; Ackermann, Marcelo; Vacanti, Giuseppe; Guenther, Ramses; Haneveld, Jeroen; Riekerink, Mark Olde; van Baren, Coen; Kampf, Dirk; Zuknik, Karl-Heinz; Christensen, Finn; Della Monica Ferreira, Desiree; Jakobsen, Anders Clemen; Krumrey, Michael; Müller, Peter; Burwitz, Vadim; Pareschi, Giovanni; Ghigo, Mauro
2014-07-01
With the selection of "The hot and energetic Universe" as science theme for ESA's second large class mission (L2) in the Cosmic Vision programme, work is focusing on the technology preparation for an advanced X-ray observatory. The core enabling technology for the high performance mirror is the Silicon Pore Optics (SPO) [1 to 23], a modular X-ray optics technology, which utilises processes and equipment developed for the semiconductor industry. The paper provides an overview of the programmatic background, the status of SPO technology and gives an outline of the development roadmap and activities undertaken and planned by ESA on optics, coatings [24 to 30] and test facilities [31, 33].
Feasibility study on the development of tough, moisture-resistant laminating resins
NASA Technical Reports Server (NTRS)
Brand, R. A.; Harrison, E. S.
1979-01-01
The potential of cyanate resins as replacement for epoxy resins in composites with graphite fiber reinforcement was investigated in an effort to provide improved moisture resistance and toughness in laminating systems at a projected cost, handleability, and processing requirements equivalent to 400 K (260 F) curing epoxies. Monomer synthesis, formulation, blending, resin preparation, catalysis studies, prepreg preparation, laminate fabrication, and testing are discussed. A graphite fiber reinforced laminate was developed with 95 percent retention of the original 363 K (180 F) flexural strength and 70 percent retention of the 363 K (180 F) short beam shear strength after 500 hour exposure to 95 + 7 relative humidity at 324 K (120 F).
The instruments of higher order thinking skills
NASA Astrophysics Data System (ADS)
Ahmad, S.; Prahmana, R. C. I.; Kenedi, A. K.; Helsa, Y.; Arianil, Y.; Zainil, M.
2017-12-01
This research developed the standard of instrument for measuring the High Order Thinking Skill (HOTS) ability of PGSD students. The research method used is development research with eight steps namely theoretical studies, operational definition, designation construct, dimensions and indicators, the preparation of the lattice, the preparation of grain, an analysis of legibility and Social desirability, field trials, and data analysis. In accordance with the type of data to be obtained in this study, the research instrument using validation sheet, implementation observation, and questionnaire. The results show that the instruments are valid and feasible to be used by expert and have been tested on PGSD students with 60% of PGSD students with low categorization.
Giechaskiel, Barouch; Vlachos, Theodoros; Riccobono, Francesco; Forni, Fausto; Colombo, Rinaldo; Montigny, Francois; Le-Lijour, Philippe; Carriero, Massimo; Bonnel, Pierre; Weiss, Martin
2016-12-04
Vehicles are tested in controlled and relatively narrow laboratory conditions to determine their official emission values and reference fuel consumption. However, on the road, ambient and driving conditions can vary over a wide range, sometimes causing emissions to be higher than those measured in the laboratory. For this reason, the European Commission has developed a complementary Real-Driving Emissions (RDE) test procedure using the Portable Emissions Measurement Systems (PEMS) to verify gaseous pollutant and particle number emissions during a wide range of normal operating conditions on the road. This paper presents the newly-adopted RDE test procedure, differentiating six steps: 1) vehicle selection, 2) vehicle preparation, 3) trip design, 4) trip execution, 5) trip verification, and 6) calculation of emissions. Of these steps, vehicle preparation and trip execution are described in greater detail. Examples of trip verification and the calculations of emissions are given.
Validation of Physics Standardized Test Items
NASA Astrophysics Data System (ADS)
Marshall, Jill
2008-10-01
The Texas Physics Assessment Team (TPAT) examined the Texas Assessment of Knowledge and Skills (TAKS) to determine whether it is a valid indicator of physics preparation for future course work and employment, and of the knowledge and skills needed to act as an informed citizen in a technological society. We categorized science items from the 2003 and 2004 10th and 11th grade TAKS by content area(s) covered, knowledge and skills required to select the correct answer, and overall quality. We also analyzed a 5000 student sample of item-level results from the 2004 11th grade exam using standard statistical methods employed by test developers (factor analysis and Item Response Theory). Triangulation of our results revealed strengths and weaknesses of the different methods of analysis. The TAKS was found to be only weakly indicative of physics preparation and we make recommendations for increasing the validity of standardized physics testing..
Giechaskiel, Barouch; Vlachos, Theodoros; Riccobono, Francesco; Forni, Fausto; Colombo, Rinaldo; Montigny, Francois; Le-Lijour, Philippe; Carriero, Massimo; Bonnel, Pierre; Weiss, Martin
2016-01-01
Vehicles are tested in controlled and relatively narrow laboratory conditions to determine their official emission values and reference fuel consumption. However, on the road, ambient and driving conditions can vary over a wide range, sometimes causing emissions to be higher than those measured in the laboratory. For this reason, the European Commission has developed a complementary Real-Driving Emissions (RDE) test procedure using the Portable Emissions Measurement Systems (PEMS) to verify gaseous pollutant and particle number emissions during a wide range of normal operating conditions on the road. This paper presents the newly-adopted RDE test procedure, differentiating six steps: 1) vehicle selection, 2) vehicle preparation, 3) trip design, 4) trip execution, 5) trip verification, and 6) calculation of emissions. Of these steps, vehicle preparation and trip execution are described in greater detail. Examples of trip verification and the calculations of emissions are given. PMID:28060306
Detection of enterotoxigenic Clostridium perfringens in meat samples by using molecular methods.
Kaneko, Ikuko; Miyamoto, Kazuaki; Mimura, Kanako; Yumine, Natsuko; Utsunomiya, Hirotoshi; Akimoto, Shigeru; McClane, Bruce A
2011-11-01
To prevent food-borne bacterial diseases and to trace bacterial contamination events to foods, microbial source tracking (MST) methods provide important epidemiological information. To apply molecular methods to MST, it is necessary not only to amplify bacterial cells to detection limit levels but also to prepare DNA with reduced inhibitory compounds and contamination. Isolates carrying the Clostridium perfringens enterotoxin gene (cpe) on the chromosome or a plasmid rank among the most important food-borne pathogens. Previous surveys indicated that cpe-positive C. perfringens isolates are present in only ∼5% of nonoutbreak food samples and then only at low numbers, usually less than 3 cells/g. In this study, four molecular assays for the detection of cpe-positive C. perfringens isolates, i.e., ordinary PCR, nested PCR, real-time PCR, and loop-mediated isothermal amplification (LAMP), were developed and evaluated for their reliability using purified DNA. For use in the artificial contamination of meat samples, DNA templates were prepared by three different commercial DNA preparation kits. The four molecular assays always detected cpe when >10³ cells/g of cpe-positive C. perfringens were present, using any kit. Of three tested commercial DNA preparation kits, the InstaGene matrix kit appeared to be most suitable for the testing of a large number of samples. By using the InstaGene matrix kit, the four molecular assays efficiently detected cpe using DNA prepared from enrichment culture specimens of meat samples contaminated with low numbers of cpe-positive C. perfringens vegetative cells or spores. Overall, the current study developed molecular assay protocols for MST to detect the contamination of foods with low numbers of cells, and at a low frequency, of cpe-positive C. perfringens isolates.
Compact low temperature scanning tunneling microscope with in-situ sample preparation capability
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Jungdae; Department of Physics and EHSRC, University of Ulsan, Ulsan 680-749; Nam, Hyoungdo
2015-09-15
We report on the design of a compact low temperature scanning tunneling microscope (STM) having in-situ sample preparation capability. The in-situ sample preparation chamber was designed to be compact allowing quick transfer of samples to the STM stage, which is ideal for preparing temperature sensitive samples such as ultra-thin metal films on semiconductor substrates. Conventional spring suspensions on the STM head often cause mechanical issues. To address this problem, we developed a simple vibration damper consisting of welded metal bellows and rubber pads. In addition, we developed a novel technique to ensure an ultra-high-vacuum (UHV) seal between the copper andmore » stainless steel, which provides excellent reliability for cryostats operating in UHV. The performance of the STM was tested from 2 K to 77 K by using epitaxial thin Pb films on Si. Very high mechanical stability was achieved with clear atomic resolution even when using cryostats operating at 77 K. At 2 K, a clean superconducting gap was observed, and the spectrum was easily fit using the BCS density of states with negligible broadening.« less
Li, Jin; Zhang, Qiu-Hong; He, Jun; Liu, Er-wei; Gao, Xiu-mei; Chang, Yan-xu
2015-01-01
An improved LC-MS/MS method was developed for simultaneous determination of eleven bioactive constituents of Radix Angelicae Pubescentis and its related preparations. It was the first report on the quantification of bioactive constituents in different preparations of Radix Angelicae Pubescentis by LC-MS/MS analytical method. These samples were separated with an Agilent Zorbax Extend reversed-phase C18 column (1.8 μm, 4.6 × 100 mm) by linear gradient elution using aqueous ammonium acetate and acetonitrile as mobile phase. The flow rate was 0.3 mL min−1. The eleven bioactive constituents showed good regression (R > 0.990) within test ranges and the recoveries were in the range of 87.1–110%. The limit of detections and quantifications for most of the major constituents were less than 0.5 and 1.0 ng mL−1, respectively. All results indicated that the developed method could be readily utilized as a suitable quality control method for Radix Angelicae Pubescentis and related preparations. PMID:26078992
Ueta, Ikuo; Mizuguchi, Ayako; Fujimura, Koji; Kawakubo, Susumu; Saito, Yoshihiro
2012-10-09
A novel needle-type sample preparation device was developed for the effective preconcentration of volatile organic compounds (VOCs) in indoor air before gas chromatography-mass spectrometry (GC-MS) analysis. To develop a device for extracting a wide range of VOCs typically found in indoor air, several types of particulate sorbents were tested as the extraction medium in the needle-type extraction device. To determine the content of these VOCs, air samples were collected for 30min with the packed sorbent(s) in the extraction needle, and the extracted VOCs were thermally desorbed in a GC injection port by the direct insertion of the needle. A double-bed sorbent consisting of a needle packed with divinylbenzene and activated carbon particles exhibited excellent extraction and desorption performance and adequate extraction capacity for all the investigated VOCs. The results also clearly demonstrated that the proposed sample preparation method is a more rapid, simpler extraction/desorption technique than traditional sample preparation methods. Copyright © 2012 Elsevier B.V. All rights reserved.
Compact low temperature scanning tunneling microscope with in-situ sample preparation capability.
Kim, Jungdae; Nam, Hyoungdo; Qin, Shengyong; Kim, Sang-ui; Schroeder, Allan; Eom, Daejin; Shih, Chih-Kang
2015-09-01
We report on the design of a compact low temperature scanning tunneling microscope (STM) having in-situ sample preparation capability. The in-situ sample preparation chamber was designed to be compact allowing quick transfer of samples to the STM stage, which is ideal for preparing temperature sensitive samples such as ultra-thin metal films on semiconductor substrates. Conventional spring suspensions on the STM head often cause mechanical issues. To address this problem, we developed a simple vibration damper consisting of welded metal bellows and rubber pads. In addition, we developed a novel technique to ensure an ultra-high-vacuum (UHV) seal between the copper and stainless steel, which provides excellent reliability for cryostats operating in UHV. The performance of the STM was tested from 2 K to 77 K by using epitaxial thin Pb films on Si. Very high mechanical stability was achieved with clear atomic resolution even when using cryostats operating at 77 K. At 2 K, a clean superconducting gap was observed, and the spectrum was easily fit using the BCS density of states with negligible broadening.
ERIC Educational Resources Information Center
Ma, Jia; Cheng, Liying
2015-01-01
Test preparation for high-stakes English language tests has received increasing research attention in the language assessment field; however, little is known about what aspects of test preparation students attend to and value. In this study, we considered the perspectives of 12 Chinese students who were enrolled in various academic programs in a…
46 CFR 61.30-5 - Preparation of thermal fluid heater for inspection and test.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 2 2012-10-01 2012-10-01 false Preparation of thermal fluid heater for inspection and test. 61.30-5 Section 61.30-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PERIODIC TESTS AND INSPECTIONS Tests and Inspections of Fired Thermal Fluid Heaters § 61.30-5 Preparation of thermal fluid heater for...
Manual for the Bateria de Examenes de Aptitud General (BEAG). Section II. Development.
ERIC Educational Resources Information Center
Employment of Training Administration (DOL), Washington, DC. Office of Research and Development.
The development and norming of a Spanish language edition of the United States Employment Service (USES) General Aptitude Test Battery (GATB) is described. The new edition, called the Bateria de Examenes de Aptitud General (BEAG), was designed to replace an earlier translation, the BGPA, prepared for use in Puerto Rico. Forms A and B were…
ERIC Educational Resources Information Center
Nafissi, Zohreh; Rezaeipanah, Fariba; Monsefi, Roya
2017-01-01
Iran's education system is exam-based and to gain admission to universities at undergraduate, graduate, and postgraduate levels, candidates have to sit a competitive examination. For this reason, developing an EAP course which prepares the candidates for these examinations is of crucial importance. The present study attempted to develop an EAP…
ERIC Educational Resources Information Center
Mahasneh, Omar. M.; Farajat, Amani. M.
2015-01-01
The present research was conducted to identify the effectiveness of a training program based on practice of careers in vocational interests development, to answer questions about the study and test its hypothesis the training program had been prepared and the adoption of a measure of vocational interests, as validity and reliability of each of…
Department of Defense Acquisition of Vaccine Production. Volume 1
2000-12-01
and by Science Applications International Corporation (SAIC) under a contract with the Office of the Director, Defense Research and Engineering...development clinical trials, manufacturing, and development; requires application of state-of- testing the-art research capability to problem solving...trials, vaccine recommending usage manufacturing scale, and logistics bodies (e.g., AFEB, ACIP) License application Prepare and submit -100 volume
Preparing novice teachers to develop basic reading and spelling skills in children.
Spear-Swerling, Louise; Brucker, Pamela Owen
2004-12-01
This study examined the word-structure knowledge of novice teachers and the progress of children tutored by a subgroup of the teachers. Teachers' word-structure knowledge was assessed using three tasks: graphophonemic segmentation, classification of pseudowords by syllable type, and classification of real words as phonetically regular or irregular. Tutored children were assessed on several measures of basic reading and spelling skills. Novice teachers who received word-structure instruction outperformed a comparison group of teachers in word-structure knowledge at post-test. Tutored children improved significantly from pre-test to post-test on all assessments. Teachers' post-test knowledge on the graphophonemic segmentation and irregular words tasks correlated significantly with tutored children's progress in decoding phonetically regular words; error analyses indicated links between teachers' patterns of word-structure knowledge and children's patterns of decoding progress. The study suggests that word-structure knowledge is important to effective teaching of word decoding and underscores the need to include this information in teacher preparation.
NASA Technical Reports Server (NTRS)
Karon, D. M.; Patel, S. K.; Zoladz, T. F.
2016-01-01
In 2009 and 2010, Concepts NREC prepared for and performed a series of tests on a 52% scale of a version of the Pratt & Whitney Rocketdyne J-2X Oxidizer Turbopump under a Phase III SBIR with NASA MSFC. The test article was a combined inducer and impeller, tested as a unit. This paper presents an overview of the test rig and facility, instrumentation, signal conditioning, data acquisition systems, testing approach, measurement developments, and lessons learned. Results from these tests were presented in the form of two papers at the previous JANNAF joint propulsion conference, in December of 2011.
Orion EFT-1 Heat Shield Offload from Truck onto Foam Pads (Dunna
2017-04-27
Inside High Bay 2 in the Vehicle Assembly Building (VAB) at NASA's Kennedy Space Center in Florida, workers help prepare the Orion heat shield from Exploration Flight Test-1 for unloading off its transporter. The heat shield is being transferred from the Orion Program to the Ground Systems Development and Operations Program, Landing and Recovery Operations. In the VAB, the heat shield will be integrated with the Orion ground test article and used for future underway recovery testing.
Orion EFT-1 Heat Shield Offload from Truck onto Foam Pads (Dunna
2017-04-27
Inside High Bay 2 in the Vehicle Assembly Building (VAB) at NASA's Kennedy Space Center in Florida, a worker helps prepare the Orion heat shield from Exploration Flight Test-1 for unloading off its transporter. The heat shield is being transferred from the Orion Program to the Ground Systems Development and Operations Program, Landing and Recovery Operations. In the VAB, the heat shield will be integrated with the Orion ground test article and used for future underway recovery testing.
New cleaning technologies advance coal
DOE Office of Scientific and Technical Information (OSTI.GOV)
Onursal, B.
1984-05-01
Alternative options are discussed for reducing sulfur dioxide emissions from coal burning utility and industrial sources. Test results indicate that it may be most advantageous to use the AED Process after coal preparation or on coals that do not need much ash removal. However, the developer claims that research efforts after 1981 have led to process improvements for producing clean coals containing 1.5% to 3% ash. This paper describes the test facility where a full-scale test of the AED Process is underway.
Orion EFT-1 Heat Shield Move from LASF to VAB Highbay 2
2017-04-26
Inside the Launch Abort System Facility at NASA's Kennedy Space Center in Florida, the Orion heat shield from Exploration Flight Test-1 is being prepared for its move to the Vehicle Assembly Building (VAB). The heat shield is being transferred from the Orion Program to the Ground Systems Development and Operations Program, Landing and Recovery Operations. In the VAB, the heat shield will be integrated with the Orion ground test article and used for future underway recovery testing.
Directed Test Review and Self-Evaluation Using a Microcomputer
Franklin, Kenneth J.; Hodder, Richard A.; Riordan, Daniel D.; Manning, Randolph
1981-01-01
Medical students adopt various review strategies to prepare for the tests administered by the National Board of Medical Examiners (NBME). The Uniformed Services University Board Review System (UBRS) was created to fill a perceived need by some students for a directed, intensive study aid based on questions in NBME format. In its current form, it is a useful adjunct for directed study, development of test-taking skills, and review of course material in any subject to which it is applied.
Preparing for the SAT: A Review
ERIC Educational Resources Information Center
Appelrouth, Jed I.; Zabrucky, Karen M.
2017-01-01
In 2016, more than 1.6 million students took the Scholastic Aptitude Test (SAT), a standardized college admissions test (College Board 2016a). Researchers have estimated that 33 percent of students who take the SAT participate in some mode of formal test preparation, such as private tutoring or classes, to prepare for the exam (Buchmann, Condron…
30 CFR 7.48 - Acid resistance test.
Code of Federal Regulations, 2010 CFR
2010-07-01
...) Test procedures. (1) Prepare one sample each of the insulated surfaces of the battery box and of the... for the battery box and cover, only one sample need be prepared and tested. (2) Prepare a 30 percent... insulation plus the battery cover or box material. The insulation thickness shall be representative of that...
30 CFR 7.48 - Acid resistance test.
Code of Federal Regulations, 2014 CFR
2014-07-01
...) Test procedures. (1) Prepare one sample each of the insulated surfaces of the battery box and of the... for the battery box and cover, only one sample need be prepared and tested. (2) Prepare a 30 percent... insulation plus the battery cover or box material. The insulation thickness shall be representative of that...
30 CFR 7.48 - Acid resistance test.
Code of Federal Regulations, 2013 CFR
2013-07-01
...) Test procedures. (1) Prepare one sample each of the insulated surfaces of the battery box and of the... for the battery box and cover, only one sample need be prepared and tested. (2) Prepare a 30 percent... insulation plus the battery cover or box material. The insulation thickness shall be representative of that...
A silicon dioxide modified magnetic nanoparticles-labeled lateral flow strips for HBs antigen.
Zhang, Xueqing; Jiang, Lin; Zhang, Chunlei; Li, Ding; Wang, Can; Gao, Feng; Cui, Daxiang
2011-12-01
Herein we reported a new type of silicon dioxide wrapped magnetic nanoparticles-labeled lateral flow strip for detection of HBs antigen in sera. The SiO2 wrapped Fe3O4 nanocomposites were prepared and characterized by HR-TEM, FTIR and magnetometer. As-prepared nanocomposites were used to label anti-HBV surface monoclonal antibody, the lateral flow strips were constructed, and 100 specimens of sera were collected and tested. Results showed that the prepared SiO2 wrapped Fe3O4 nanocomposites were shell/core structure, well dispersed, with the size of 25 nm in diameter, the thickness of the shell was about 3 nm, their magnetic saturation intensity was 44.3 meu g(-1). Clinical sera specimens test results showed that the prepared lateral flow strips were with the detection limitation of 5 pg/mL by naked eye observation, and 0.1 pg/mL by CCD reader or MAR Analyzer, specificity was 100%. In conclusion, one kind of silicon dioxide wrapped magnetic nanoparticles-labeled lateral flow strip for ultrasensitive detection of HBs antigen was successfully developed, its ease of use, sensitiveness and low-cost make it well-suited for population-based on-the-site hepatitis B screening.
Walter, Benjamin Michael; Klare, Peter; Neu, Bruno; Schmid, Roland M; von Delius, Stefan
2016-06-21
In gastroenterology a sufficient colon cleansing improves adenoma detection rate and prevents the need for preterm repeat colonoscopies due to invalid preparation. It has been shown that patient education is of major importance for improvement of colon cleansing. Objective of this study was to assess the function of an automated text messaging (short message service, SMS)-supported colonoscopy preparation starting 4 days before colonoscopy appointment. After preevaluation to assess mobile phone usage in the patient population for relevance of this approach, a Web-based, automated SMS text messaging system was developed, following which a single-center feasibility study at a tertiary care center was performed. Patients scheduled for outpatient colonoscopy were invited to participate. Patients enrolled in the study group received automated information about dietary recommendations and bowel cleansing during colonoscopy preparation. Data of outpatient colonoscopies with regular preparation procedure were used for pair matching and served as control. Primary end point was feasibility of SMS text messaging support in colonoscopy preparation assessed as stable and satisfactory function of the system. Secondary end points were quality of bowel preparation according to the Boston Bowel Preparation Scale (BBPS) and patient satisfaction with SMS text messaging-provided information assessed by a questionnaire. Web-based SMS text messaging-supported colonoscopy preparation was successful and feasible in 19 of 20 patients. Mean (standard error of the mean, SEM) total BBPS score was slightly higher in the SMS group than in the control group (7.3, SEM 0.3 vs 6.4, SEM 0.2) and for each colonic region (left, transverse, and right colon). Patient satisfaction regarding SMS text messaging-based information was high. Using SMS for colonoscopy preparation with 4 days' guidance including dietary recommendation is a new approach to improve colonoscopy preparation. Quality of colonoscopy preparation was sufficient and patients were highly satisfied with the system during colonoscopy preparation.
Klare, Peter; Neu, Bruno; Schmid, Roland M; von Delius, Stefan
2016-01-01
Background In gastroenterology a sufficient colon cleansing improves adenoma detection rate and prevents the need for preterm repeat colonoscopies due to invalid preparation. It has been shown that patient education is of major importance for improvement of colon cleansing. Objective Objective of this study was to assess the function of an automated text messaging (short message service, SMS)–supported colonoscopy preparation starting 4 days before colonoscopy appointment. Methods After preevaluation to assess mobile phone usage in the patient population for relevance of this approach, a Web-based, automated SMS text messaging system was developed, following which a single-center feasibility study at a tertiary care center was performed. Patients scheduled for outpatient colonoscopy were invited to participate. Patients enrolled in the study group received automated information about dietary recommendations and bowel cleansing during colonoscopy preparation. Data of outpatient colonoscopies with regular preparation procedure were used for pair matching and served as control. Primary end point was feasibility of SMS text messaging support in colonoscopy preparation assessed as stable and satisfactory function of the system. Secondary end points were quality of bowel preparation according to the Boston Bowel Preparation Scale (BBPS) and patient satisfaction with SMS text messaging–provided information assessed by a questionnaire. Results Web-based SMS text messaging–supported colonoscopy preparation was successful and feasible in 19 of 20 patients. Mean (standard error of the mean, SEM) total BBPS score was slightly higher in the SMS group than in the control group (7.3, SEM 0.3 vs 6.4, SEM 0.2) and for each colonic region (left, transverse, and right colon). Patient satisfaction regarding SMS text messaging–based information was high. Conclusions Using SMS for colonoscopy preparation with 4 days’ guidance including dietary recommendation is a new approach to improve colonoscopy preparation. Quality of colonoscopy preparation was sufficient and patients were highly satisfied with the system during colonoscopy preparation. PMID:27329204
B-1 AFT Nacelle Flow Visualization Study
NASA Technical Reports Server (NTRS)
Celniker, Robert
1975-01-01
A 2-month program was conducted to perform engineering evaluation and design tasks to prepare for visualization and photography of the airflow along the aft portion of the B-1 nacelles and nozzles during flight test. Several methods of visualizing the flow were investigated and compared with respect to cost, impact of the device on the flow patterns, suitability for use in the flight environment, and operability throughout the flight. Data were based on a literature search and discussions with the test personnel. Tufts were selected as the flow visualization device in preference to several other devices studied. A tuft installation pattern has been prepared for the right-hand aft nacelle area of B-1 air vehicle No.2. Flight research programs to develop flow visualization devices other than tufts for use in future testing are recommended. A design study was conducted to select a suitable motion picture camera, to select the camera location, and to prepare engineering drawings sufficient to permit installation of the camera. Ten locations on the air vehicle were evaluated before the selection of the location in the horizontal stabilizer actuator fairing. The considerations included cost, camera angle, available volume, environmental control, flutter impact, and interference with antennas or other instrumentation.
A program evaluation of Protovation Camp at an elementary school in North Carolina
NASA Astrophysics Data System (ADS)
Cavoly, Denise Y.
The purpose of this program evaluation was to investigate the impact over time teachers' self-efficacies and the outcome expectancies of those who participated in an inquiry-based, hands-on, constructivist professional development program to learn science content. The hope was that after active participation in this inquiry-based professional development program that provides science inquiry experiences, the teachers, graduate students and elementary students would gain content knowledge, increase self-efficacies, and provide the outcome expectancies of the learning development program that provides science inquiry experiences. The mixed-methods approach used quantitative and qualitative data for campers, which consisted of pre-test and post-test scores on the Test of Science-Related Attitudes (TOSRA), the Draw-A-Scientist Test, Science Process Skills Inventory (SPSI) and content tests based on the camp activities. Additionally, TOSRA scores, Teacher Sense of Efficacy Scale (TSES), and Thinking about Science Survey (TSSI) results for the graduate students and elementary teachers were used along with qualitative data collected from plusdelta charts and interviews to determine the impact of participation in Protovation Camp on teachers and students. Results of the program evaluation indicated that when students were taught inquiry-based lessons that ignite wonder, both their attitudes toward science and their knowledge about science improved. An implication for teacher preparation programs was that practicing inquiry-based lessons on actual elementary students was an important component for teachers and graduate students as they prepare to positively impact student learning in their own classrooms. The findings of this study suggest that it is not just the length of the professional development program that is crucial, but the need for an implementation period while teachers work to transfer the learning to the classroom to their own students is critical to the success of process.
End-preparation assessments and tests for compounded sterile preparations.
McElhiney, Linda F
2013-01-01
Outsourcing has become a necessity to obtain sterile products that are currently on backorder. Because of the expense of outsourcing sterile compounding, pharmacy leadership in health systems are now considering the option of insourcing and batch preparing compounded sterile preparations, which can be a viable option for a health system. It can significantly decrease drug-spending costs, and the pharmacy has a complete record of the compounding process. The key to preparing high-quality, safe, sterile preparations and meeting United States Pharmacopeia standards is end-preparation assessments and tests.
ChemCam Mast Unit Being Prepared for Laser Firing
2010-12-23
Researchers prepare for a test of the Chemistry and Camera ChemCam instrument that will fly on NASA Mars Science Laboratory mission; researchers are preparing the instrument mast unit for a laser firing test.
Development and Test Plans for the MSR EEV
NASA Technical Reports Server (NTRS)
Dillman, Robert; Laub, Bernard; Kellas, Sotiris; Schoenenberger, Mark
2005-01-01
The goal of the proposed Mars Sample Return mission is to bring samples from the surface of Mars back to Earth for thorough examination and analysis. The Earth Entry Vehicle is the passive entry body designed to protect the sample container from entry heating and deceleration loads during descent through the Earth s atmosphere to a recoverable location on the surface. This paper summarizes the entry vehicle design and outlines the subsystem development and testing currently planned in preparation for an entry vehicle flight test in 2010 and mission launch in 2013. Planned efforts are discussed for the areas of the thermal protection system, vehicle trajectory, aerodynamics and aerothermodynamics, impact energy absorption, structure and mechanisms, and the entry vehicle flight test.
Teaching of students technology early professional orientation of schoolchildren
NASA Astrophysics Data System (ADS)
Gilmanshina, S. I.; Sagitova, R. N.; Gilmanshin, I. R.; Kamaleeva, A. R.
2017-09-01
The necessity of early professional orientation of schoolchildren on the engineering profession and a new type of teacher was proved. Theoretically substantiated and experimentally tested pedagogical conditions of training of students - future teachers of technology early professional orientation of schoolchildren in the system of university preparation of teacher of a new type. This development of courses of special disciplines, aimed at developing of future teachers of readiness for early career guidance activities; development of interactive group projects for schoolchildren of different age groups (including primary school), expanding their understanding of the world of professions; practical testing of career guidance projects dealing with children’s audience.
Life sciences on-line: A study in hypermedia application
NASA Technical Reports Server (NTRS)
Christman, Linda A.; Hoang, Nam V.; Proctor, David R.
1990-01-01
The main objective was to determine the feasibility of using a computer-based interactive information recall module for the Life Sciences Project Division (LSPD) at NASA, Johnson Space Center. LSPD personnel prepare payload experiments to test and monitor physiological functions in zero gravity. Training refreshers and other types of online help are needed to support personnel in their tasks during mission testing and in flight. Results of a survey of other hypermedia and multimedia developers and lessons learned by the developer of the LSPD prototype module are presented. Related issues and future applications are also discussed and further hypermedia development within the LSPD is recommended.
Design and fabrication of solar cell modules
NASA Technical Reports Server (NTRS)
Shaughnessy, T. P.
1978-01-01
A program conducted for design, fabrication and evaluation of twelve silicon solar cell modules is described. The purpose of the program was to develop a module design consistent with the requirements and objectives of JPL specification and to also incorporate elements of new technologies under development to meet LSSA Project goals. Module development emphasized preparation of a technically and economically competitive design based upon utilization of ion implanted solar cells and a glass encapsulation system. The modules fabricated, tested and delivered were of nominal 2 X 2 foot dimensions and 20 watt minimum rating. Basic design, design rationale, performance and results of environmental testing are described.
3D Printing of Thermo-Responsive Methylcellulose Hydrogels for Cell-Sheet Engineering
Cochis, Andrea; Sorrentino, Rita; Grassi, Federico; Leigheb, Massimiliano; Farè, Silvia
2018-01-01
A possible strategy in regenerative medicine is cell-sheet engineering (CSE), i.e., developing smart cell culture surfaces from which to obtain intact cell sheets (CS). The main goal of this study was to develop 3D printing via extrusion-based bioprinting of methylcellulose (MC)-based hydrogels. Hydrogels were prepared by mixing MC powder in saline solutions (Na2SO4 and PBS). MC-based hydrogels were analyzed to investigate the rheological behavior and thus optimize the printing process parameters. Cells were tested in vitro on ring-shaped printed hydrogels; bulk MC hydrogels were used for comparison. In vitro tests used murine embryonic fibroblasts (NIH/3T3) and endothelial murine cells (MS1), and the resulting cell sheets were characterized analyzing cell viability and immunofluorescence. In terms of CS preparation, 3D printing proved to be an optimal approach to obtain ring-shaped CS. Cell orientation was observed for the ring-shaped CS and was confirmed by the degree of circularity of their nuclei: cell nuclei in ring-shaped CS were more elongated than those in sheets detached from bulk hydrogels. The 3D printing process appears adequate for the preparation of cell sheets of different shapes for the regeneration of complex tissues. PMID:29642573
Ukrainian Program for Material Science in Microgravity
NASA Astrophysics Data System (ADS)
Fedorov, Oleg
Ukrainian Program for Material Sciences in Microgravity O.P. Fedorov, Space Research Insti-tute of NASU -NSAU, Kyiv, The aim of the report is to present previous and current approach of Ukrainian research society to the prospect of material sciences in microgravity. This approach is based on analysis of Ukrainian program of research in microgravity, preparation of Russian -Ukrainian experiments on Russian segment of ISS and development of new Ukrainian strategy of space activity for the years 2010-2030. Two parts of issues are discussed: (i) the evolution of our views on the priorities in microgravity research (ii) current experiments under preparation and important ground-based results. item1 The concept of "space industrialization" and relevant efforts in Soviet and post -Soviet Ukrainian research institutions are reviewed. The main topics are: melt supercooling, crystal growing, testing of materials, electric welding and study of near-Earth environment. The anticipated and current results are compared. item 2. The main experiments in the framework of Ukrainian-Russian Research Program for Russian Segment of ISS are reviewed. Flight installations under development and ground-based results of the experiments on directional solidification, heat pipes, tribological testing, biocorrosion study is presented. Ground-based experiments and theoretical study of directional solidification of transparent alloys are reviewed as well as preparation of MORPHOS installation for study of succinonitrile -acetone in microgravity.
DOT National Transportation Integrated Search
2014-01-01
The objective of this project was to develop system designs for programs to monitor travel time reliability and to prepare a guidebook that practitioners and others can use to design, build, operate, and maintain such systems. Generally, such travel ...
Pilot testing of SHRP 2 reliability data and analytical products: Minnesota. [supporting datasets
DOT National Transportation Integrated Search
2014-01-01
The objective of this project was to develop system designs for programs to monitor travel time reliability and to prepare a guidebook that practitioners and others can use to design, build, operate, and maintain such systems. Generally, such travel ...
The Franchising of Private Tutoring: A View from Canada
ERIC Educational Resources Information Center
Davies, Scott; Aurini, Janice
2006-01-01
Private tutoring is a growing industry that is being transformed by an evolution from "shadow education" provision into "learning center" franchises. Traditional shadow educators closely follow the school curriculum, offering short-term homework help and test preparation. Learning centers develop their own curricular and…
DOT National Transportation Integrated Search
2013-06-01
This Demonstration Plan has been prepared to provide guidance and a common definition to all parties of the testing program that will be conducted for the LA-Gateway FRATIS Demonstration Project. More specifically, this document provides: Plannin...
Energy by the Numbers: Collegiate Wind Competition
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
2016-05-19
The U.S. Department of Energy Collegiate Wind Competition prepares students from multiple disciplines to enter tomorrow’s wind energy workforce. As part of the competition, undergraduate students build and test a wind turbine, establish a deployment strategy, and develop and deliver a business plan.
Laibhen-Parkes, Natasha; Kimble, Laura P; Melnyk, Bernadette Mazurek; Sudia, Tanya; Codone, Susan
2018-06-01
Instruments used to assess evidence-based practice (EBP) competence in nurses have been subjective, unreliable, or invalid. The Fresno test was identified as the only instrument to measure all the steps of EBP with supportive reliability and validity data. However, the items and psychometric properties of the original Fresno test are only relevant to measure EBP with medical residents. Therefore, the purpose of this paper is to describe the development of the adapted Fresno test for pediatric nurses, and provide preliminary validity and reliability data for its use with Bachelor of Science in Nursing-prepared pediatric bedside nurses. General adaptations were made to the original instrument's case studies, item content, wording, and format to meet the needs of a pediatric nursing sample. The scoring rubric was also modified to complement changes made to the instrument. Content and face validity, and intrarater reliability of the adapted Fresno test were assessed during a mixed-methods pilot study conducted from October to December 2013 with 29 Bachelor of Science in Nursing-prepared pediatric nurses. Validity data provided evidence for good content and face validity. Intrarater reliability estimates were high. The adapted Fresno test presented here appears to be a valid and reliable assessment of EBP competence in Bachelor of Science in Nursing-prepared pediatric nurses. However, further testing of this instrument is warranted using a larger sample of pediatric nurses in diverse settings. This instrument can be a starting point for evaluating the impact of EBP competence on patient outcomes. © 2018 Sigma Theta Tau International.
2009-12-11
CAPE CANAVERAL, Fla. – Workers prepare to lower the second stage of a Delta IV rocket from a test cell in the hangar of the Delta Operations Center at Cape Canaveral Air Force Station in Florida into a turnover stand following the completion of nozzle extension deployment system testing. The United Launch Alliance Delta IV rocket is slated to launch GOES-P, the latest Geostationary Operational Environmental Satellite developed by NASA for the National Oceanic and Atmospheric Administration, or NOAA. Next, the second stage will be transported to the Horizontal Integration Facility where it will be inspected and prepared for mating with the Delta IV rocket's first stage. GOES-P, a meteorological satellite, is designed to watch for storm development and observed current weather conditions on Earth. Launch of GOES-P is scheduled for no earlier than Feb. 25, 2010, from Launch Complex 37. For information on GOES-P, visit http://goespoes.gsfc.nasa.gov/goes/spacecraft/n_p_spacecraft.html. Photo credit: NASA/Glenn Benson
Architecture for Variable Data Entry into a National Registry.
Goossen, William
2017-01-01
The Dutch perinatal registry required a new architecture due to the large variability of the submitted data from midwives and hospitals. The purpose of this article is to describe the healthcare information architecture for the Dutch perinatal registry. requirements analysis, design, development and testing. The architecture is depicted for its components and preliminary test results. The data entry and storage work well, the Data Marts are under preparation.
ERIC Educational Resources Information Center
Jacobs, Clinton O.
The report is an evaluation of the effectiveness of the 12 instructional units developed around the use of the Briggs-Stratton Model 80302, 3HP, 8 cu. in. displacement engine having a fuel induction system similar in construction to farm tractor types. The evaluation procedure used was the "one-group Pre-test and Post-test" research method. The…
2014-08-04
SAN DIEGO, Calif. – Inside the well deck of the USS Anchorage, NASA, Lockheed Martin and U.S. Navy personnel monitor the Orion boilerplate test vehicle as the well deck fills with water. Tending lines have been attached to the test vehicle in preparation for an evolution of Underway Recovery Test 2 in the Pacific Ocean off the coast of San Diego. The test is being conducted to prepare for recovery of the Orion crew module on its return from a deep space mission. The underway recovery test will allow the teams to demonstrate and evaluate the recovery processes, procedures, new hardware and personnel in open waters. The Ground Systems Development and Operations Program is conducting the underway recovery test. Orion is the exploration spacecraft designed to carry astronauts to destinations not yet explored by humans, including an asteroid and Mars. It will have emergency abort capability, sustain the crew during space travel and provide safe re-entry from deep space return velocities. The first unpiloted test flight of the Orion is scheduled to launch in 2014 atop a Delta IV rocket and in 2017 on NASA’s Space Launch System rocket. For more information, visit http://www.nasa.gov/orion. Photo credit: NASA/Kim Shiflett
2014-09-17
SAN DIEGO, Calif. – During the third day of Orion Underway Recovery Test 3 on the USS Anchorage in the Pacific Ocean, two Zodiac boats with U.S. Navy divers aboard, at left, and two rigid hull inflatable boats with Navy and other team personnel aboard, prepare for recovery of the Orion boilerplate test vehicle. NASA, Lockheed Martin and U.S. Navy personnel are conducting recovery tests using the Orion boilerplate test vehicle to prepare for recovery of the Orion crew module on its return from a deep space mission. The test allows the teams to demonstrate and evaluate the recovery processes, procedures, hardware and personnel in open waters. The Ground Systems Development and Operations Program is conducting the underway recovery tests. Orion is the exploration spacecraft designed to carry astronauts to destinations not yet explored by humans, including an asteroid and Mars. It will have emergency abort capability, sustain the crew during space travel and provide safe re-entry from deep space return velocities. The first unpiloted test flight of Orion is scheduled to launch in 2014 atop a United Launch Alliance Delta IV Heavy rocket and in 2018 on NASA’s Space Launch System rocket. For more information, visit http://www.nasa.gov/orion. Photo credit: NASA/Kim Shiflett
Bendas, Ehab Rasmy; Basalious, Emad B
2016-01-01
Our objective was to develop novel vagina retentive cream suppositories (VRCS) of progesterone having rapid disintegration and good vaginal retention. VRCS of progesterone were prepared using oil in water (o/w) emulsion of mineral oil or theobroma oil in hard fat and compared with conventional vaginal suppositories (CVS) prepared by hard fat. VRCS formulations were tested for content uniformity, disintegration, melting range, in vitro release and stability studies. The most stable formulation (VRCS I) was subjected to scaling-up manufacturing and patients' satisfaction test. The rapid disintegration, good retentive properties are applicable through the inclusion of emulsified theobroma oil rather than hydrophilic surfactant into the hard fat bases. The release profile of progesterone from VRCS I showed a biphasic pattern due to the formation of progesterone reservoir in the emulsified theobroma oil. All volunteers involved in patients' satisfaction test showed high satisfactory response to the tested formulation (VRCS). The in vivo pharmacokinetic study suggests that VRCS of progesterone provided higher rate and extent of absorption compared to hard fat based suppositories. Our results proposed that emulsified theobroma oil could be promising to solve the problems of poor patients' satisfaction and variability of drug absorption associated with hard fat suppositories.
2014-09-15
SAN DIEGO, Calif. – Helicopter Sea Combat Squadron 8, or HSC 8, prepare an H60-S Seahawk for flight on the deck of the USS Anchorage during the first day of Orion Underway Recovery Test 3 activities in the Pacific Ocean. NASA, Lockheed Martin and U.S. Navy personnel are conducting recovery tests to prepare for recovery of the Orion crew module on its return from a deep space mission. The test will allow the teams to demonstrate and evaluate the recovery processes, procedures, hardware and personnel in open waters. The Ground Systems Development and Operations Program is conducting the underway recovery tests. Orion is the exploration spacecraft designed to carry astronauts to destinations not yet explored by humans, including an asteroid and Mars. It will have emergency abort capability, sustain the crew during space travel and provide safe re-entry from deep space return velocities. The first unpiloted test flight of Orion is scheduled to launch in 2014 atop a United Launch Alliance Delta IV Heavy rocket and in 2018 on NASA’s Space Launch System rocket. For more information, visit http://www.nasa.gov/orion. Photo credit: NASA/Cory Huston
°Enhancing High Temperature Anode Performance with 2° Anchoring Phases
DOE Office of Scientific and Technical Information (OSTI.GOV)
Walker, Robert A.; Sofie, Stephen W.; Amendola, Roberta
2015-10-01
Project accomplishments included developing and optimizing strength testing of aluminum titanate (ALT)-doped Ni-YSZ materials and identified the dopant levels that optimized mechanical strength and enhanced electrochemical performance. We also optimized our ability to fabricate electrolyte supported button cells with anodes consisting of powders provided by Fuel Cell Energy. In several instances, those anodes were infiltrated with ALT and tested with hydrogen for 30 hours at 800°C at an applied potential of 0.4 V. Our research activities were focused in three areas: 1) mechanical strength testing on as prepared and reducced nickel-YSZ structures that were either free of a dopant ormore » prepared by mechanically mixing in ALT at various weight percents (up to 10 wt%); 2) 24-hour electrochemical testing of electroylte supported cells having anodes made from Ni/YSZ and Ni/YSZ/ALT anodes with specific attention focused on modeling degradation rates; and 3) operando EIS and optical testing of both in-house fabricated devices as well as membrane electrode assemblies that were acquired from commercial vendors.« less
Cho, JeongHyeon; Lee, SeungHee; Shin, Jung A; Kim, Jeong Ho; Lee, Hong Sub
2017-01-01
Background/Aims Few studies have evaluated the use of a smartphone application (app) for educating people undergoing colonoscopy and optimizing bowel preparation. Therefore, this study was designed to develop a smartphone app for people to use as a preparation guide and to evaluate the efficacy of this app when used prior to colonoscopy. Methods In total, 142 patients (male:female=84:58, mean age=43.5±9.3 years), who were scheduled to undergo a colonoscopy at Myongji Hospital, were enrolled in this study. Seventy-one patients were asked to use a smartphone app that we had recently developed to prepare for the colonoscopy, while the 71 patients of the sex and age-matched control group were educated via written and verbal instructions. Results The quality of bowel cleansing, evaluated using the Boston Bowel Preparation Scale, was significantly higher in the smartphone app group than in the control group (7.70±1.1 vs. 7.24±0.8, respectively, p=0.007 by t-test). No significant differences were found between the two groups regarding work-up time and the number of patients with polyps. Conclusions In this study, targeting young adults (≤50 years), the bowel preparation achieved by patients using the smartphone app showed significantly better quality than that of the control group. PMID:28669148
Conceptual definition of a technology development mission for advanced solar dynamic power systems
NASA Technical Reports Server (NTRS)
Migra, R. P.
1986-01-01
An initial conceptual definition of a technology development mission for advanced solar dynamic power systems is provided, utilizing a space station to provide a dedicated test facility. The advanced power systems considered included Brayton, Stirling, and liquid metal Rankine systems operating in the temperature range of 1040 to 1400 K. The critical technologies for advanced systems were identified by reviewing the current state of the art of solar dynamic power systems. The experimental requirements were determined by planning a system test of a 20 kWe solar dynamic power system on the space station test facility. These requirements were documented via the Mission Requirements Working Group (MRWG) and Technology Development Advocacy Group (TDAG) forms. Various concepts or considerations of advanced concepts are discussed. A preliminary evolutionary plan for this technology development mission was prepared.
78 FR 42057 - National Assessment Governing Board; Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-15
... Tasks (ICTs) at grades 4, 8, and 12 for the 2014 pilot test, in preparation for the 2015 NAEP Science assessment; (2) Science Hands-on Tasks (HOTs) at grades 4, 8, and 12 for the 2014 pilot test, in preparation...) Science Interactive Computer Tasks (ICTs) at grades 4, 8, and 12 for the 2014 pilot test, in preparation...
Test Preparation in the Accountability Era: Toward a Learning-Oriented Approach
ERIC Educational Resources Information Center
Gebril, Atta
2018-01-01
The article introduces a learning-oriented approach to test preparation that could help in easing the tension between learning and assessment. The first part of the article discusses the different concepts that are usually used in the context of test preparation. The second section reports on the literature pertaining to the effects of test…
10 CFR 26.93 - Preparing for alcohol testing.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 1 2013-01-01 2013-01-01 false Preparing for alcohol testing. 26.93 Section 26.93 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.93 Preparing... shall— (1) Ask the donor whether he or she, in the past 15 minutes, has had anything to eat or drink...
10 CFR 26.93 - Preparing for alcohol testing.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 1 2014-01-01 2014-01-01 false Preparing for alcohol testing. 26.93 Section 26.93 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.93 Preparing... shall— (1) Ask the donor whether he or she, in the past 15 minutes, has had anything to eat or drink...
10 CFR 26.93 - Preparing for alcohol testing.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 1 2012-01-01 2012-01-01 false Preparing for alcohol testing. 26.93 Section 26.93 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.93 Preparing... shall— (1) Ask the donor whether he or she, in the past 15 minutes, has had anything to eat or drink...
9 CFR 147.8 - Procedures for preparing egg yolk samples for diagnostic tests.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 9 Animals and Animal Products 1 2014-01-01 2014-01-01 false Procedures for preparing egg yolk samples for diagnostic tests. 147.8 Section 147.8 Animals and Animal Products ANIMAL AND PLANT HEALTH... IMPROVEMENT PLAN Blood Testing Procedures § 147.8 Procedures for preparing egg yolk samples for diagnostic...
9 CFR 147.8 - Procedures for preparing egg yolk samples for diagnostic tests.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 9 Animals and Animal Products 1 2013-01-01 2013-01-01 false Procedures for preparing egg yolk samples for diagnostic tests. 147.8 Section 147.8 Animals and Animal Products ANIMAL AND PLANT HEALTH... IMPROVEMENT PLAN Blood Testing Procedures § 147.8 Procedures for preparing egg yolk samples for diagnostic...
9 CFR 147.8 - Procedures for preparing egg yolk samples for diagnostic tests.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 9 Animals and Animal Products 1 2012-01-01 2012-01-01 false Procedures for preparing egg yolk samples for diagnostic tests. 147.8 Section 147.8 Animals and Animal Products ANIMAL AND PLANT HEALTH... IMPROVEMENT PLAN Blood Testing Procedures § 147.8 Procedures for preparing egg yolk samples for diagnostic...
9 CFR 147.8 - Procedures for preparing egg yolk samples for diagnostic tests.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 9 Animals and Animal Products 1 2011-01-01 2011-01-01 false Procedures for preparing egg yolk samples for diagnostic tests. 147.8 Section 147.8 Animals and Animal Products ANIMAL AND PLANT HEALTH... IMPROVEMENT PLAN Blood Testing Procedures § 147.8 Procedures for preparing egg yolk samples for diagnostic...
Development of heat-storage building materials for passive-solar applications
NASA Astrophysics Data System (ADS)
Fletcher, J. W.
A heat storage building material to be used for passive solar applications and general load leveling within building spaces was developed. Specifically, PCM-filled plastic panels are to be developed as wallboard and ceiling panels. Three PCMs (CaCl2, 6H2O; Na2SO4, 10H2O; LiNO3, 3H2O are to be evaluated for use in the double walled, hollow channeled plastic panels. Laboratory development of the panels will include determination of filling and sealing techniques, behavior of the PCMs, container properties and materials compatibility. Testing will include vapor transmission, thermal cycle, dynamic performance, accelerated life and durability tests. In addition to development and testing, an applications analysis will be performed for specific passive solar applications. Conceptual design of a single family passive solar residence will be prepared and performance evaluated. Screening of the three PCM candidates is essentially complete.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Singleton, A.H.
1995-06-28
The goal of this project is the development of a commercially-viable, cobalt-based Fischer-Tropsch (F-T) catalyst for use in a slurry bubble column reactor. The major objectives of this work are (1) to develop a cobalt-based F-T catalyst with low (< 5%) methane selectivity, (2) to develop a cobalt-based F-T catalyst with water-gas shift activity, and (3) to combine both these improvements into one catalyst. The project consists of five major tasks: catalyst development; catalyst testing; catalyst reproducibility tests; catalyst aging tests; and preliminary design and cost estimate for a demonstrate scale catalyst production facility. Technical accomplishments during this reporting periodmore » include the following. It appears that the higher activity obtained for the catalysts prepared using an organic solution and reduced directly without prior calcination was the result of higher dispersions obtained under such pretreatment. A Ru-promoted Co catalyst on alumina with 30% Co loading exhibited a 4-fold increase in dispersion and a 2-fold increase in activity in the fixed-bed reactor from that obtained with the non-promoted catalyst. Several reactor runs have again focused on pushing conversion to higher levels. The maximum conversion obtained has been 49.7% with 26g catalyst. Further investigations of the effect of reaction temperature on the performance of Co catalysts during F-T synthesis were started using a low activity catalyst and one of the most active catalysts. The three 1 kg catalyst batches prepared by Calsicat for the reproducibility and aging studies were tested in both the fixed-bed and slurry bubble column reactors under the standard reaction conditions. The effects of adding various promoters to some cobalt catalysts have also been addressed. Results are presented and discussed.« less
Methodological Issues in Antifungal Susceptibility Testing of Malassezia pachydermatis
Peano, Andrea; Pasquetti, Mario; Tizzani, Paolo; Chiavassa, Elisa; Guillot, Jacques; Johnson, Elizabeth
2017-01-01
Reference methods for antifungal susceptibility testing of yeasts have been developed by the Clinical and Laboratory Standards Institute (CLSI) and the European Committee on Antibiotic Susceptibility Testing (EUCAST). These methods are intended to test the main pathogenic yeasts that cause invasive infections, namely Candida spp. and Cryptococcus neoformans, while testing other yeast species introduces several additional problems in standardization not addressed by these reference procedures. As a consequence, a number of procedures have been employed in the literature to test the antifungal susceptibility of Malassezia pachydermatis. This has resulted in conflicting results. The aim of the present study is to review the procedures and the technical parameters (growth media, inoculum preparation, temperature and length of incubation, method of reading) employed for susceptibility testing of M. pachydermatis, and when possible, to propose recommendations for or against their use. Such information may be useful for the future development of a reference assay. PMID:29371554
Kelber, Olaf; Wegener, Tankred; Steinhoff, Barbara; Staiger, Christiane; Wiesner, Jacqueline; Knöss, Werner; Kraft, Karin
2014-01-01
An assessment of genotoxicity is a precondition for marketing authorization respectively registration of herbal medicinal products (HMPs), as well as for inclusion into the 'Community list of herbal substances, preparations and combinations thereof for use in traditional herbal medicinal products' established by the European Commission in accordance with Directive 2001/83/EC as amended, and based on proposals from the Committee on Herbal Medicinal Products (HMPC). In the 'Guideline on the assessment of genotoxicity of herbal substances/preparations' (EMEA/HMPC/107079/2007) HMPC has described a stepwise approach for genotoxicity testing, according to which the Ames test is a sufficient base for the assessment of genotoxicity in case of an unequivocally negative result. For reducing efforts for testing of individual herbal substances/preparations, HMPC has also developed the 'guideline on selection of test materials for genotoxicity testing for traditional herbal medicinal products/herbal medicinal products' (EMEA/HMPC/67644/2009) with the aim to allow testing of a standard range of test materials which could be considered representative of the commonly used preparations from a specific herbal drug according to a 'bracketing/matrixing' approach. The purpose of this paper is to provide data on the practical application of this bracketing and matrixing concept using the example of Valerianae radix, with the intention of facilitating its inclusion in the "Community list". Five extraction solvents, representing the extremes of the polarity range and including also mid-range extraction solvents, were used, covering the entire spectrum of phytochemical constituents of Valerianae radix, thereby including polar and non-polar constituents. Extracts were tested in the Ames test according to all relevant guidelines. Results were unequivocally negative for all extracts. A review of the literature showed that this result is in accordance with the available data, thus demonstrating the lack of a genotoxic potential. In conclusion the two guidelines on genotoxicity provide a practically applicable concept. Valerianae radix has no genotoxic potential, supporting its use in HMPs and its inclusion in the Community list. Copyright © 2014 The Authors. Published by Elsevier GmbH.. All rights reserved.
Development of a Work Control System for Propulsion Testing at NASA Stennis
NASA Technical Reports Server (NTRS)
Messer, Elizabeth A.
2005-01-01
This paper will explain the requirements and steps taken to develop the current Propulsion Test Directorate electronic work control system for Test Operations. The PTD Work Control System includes work authorization and technical instruction documents, such as test preparation sheets, discrepancy reports, test requests, pre-test briefing reports, and other test operations supporting tools. The environment that existed in the E-Complex test areas in the late 1990's was one of enormous growth which brought people of diverse backgrounds together for the sole purpose of testing propulsion hardware. The problem that faced us was that these newly formed teams did not have a consistent and clearly understood method for writing, performing or verifying work. A paper system was developed that would allow the teams to use the same forms, but this still presented problems in the large amount of errors occurring, such as lost paperwork and inconsistent implementation. In a sampling of errors in August 1999, the paper work control system encountered 250 errors out of 230 documents released and completed, for an error rate of 111%.
Hosny, Alaa El-Dien MS; Kashef, Mona T; Taher, Hadeer A; El-Bazza, Zeinab E
2017-01-01
Purpose Microbial contamination of different cosmetic preparations, as a result of preservative failure, presents a major public health threat. Also, most of the known preservatives have serious consumer side effects. The antimicrobial activity of zinc oxide nanoparticles (ZnO NP) is well documented. Therefore, we aimed to determine the possible use of unirradiated and γ-irradiated ZnO NP as a cosmetic preservative. Methods The possible use of ZnO NP as a preservative was tested and compared to commonly used preservatives using a challenge test. Their activity was tested in six different types of preparations. The effect of γ radiation on the antimicrobial activity of ZnO NP was tested through determination of the obtained zone diameters against different microorganisms and the total aerobic microbial count in tested preparations. The antimicrobial activity, of unirradiated and γ-irradiated ZnO NP during storage was also determined. Results ZnO NP were superior to other commonly used preservatives in all tested cosmetic preparations. They pass the challenge test in all types of tested preparations. γ irradiation enhanced their antimicrobial activity in all tested preparations. The irradiation causes a reduction in NP sizes that is directly proportional to the applied radiation dose. Upon storage, ZnO NP were effective in maintaining the microbial count of the product within the acceptable range. Their activity in stored products was enhanced by γ irradiation. Conclusion Unirradiated and γ-irradiated ZnO NP can be used as effective preservatives. They are compatible with the components of all tested products. γ irradiation enhanced the antimicrobial activity of ZnO NP. PMID:28979119
Experimental Results From a 2kW Brayton Power Conversion Unit
NASA Technical Reports Server (NTRS)
Hervol, David; Mason, Lee; Birchenough, Arthur
2003-01-01
This paper presents experimental test results from operation of a 2 kWe Brayton power conversion unit. The Brayton converter was developed for a solar dynamic power system flight experiment planned for the Mir Space Station in 1997. The flight experiment was cancelled, but the converter was tested at Glenn Research Center as part of the Solar Dynamic Ground Test Demonstration system which included a solar concentrator, heat receiver, and space radiator. In preparation for the current testing, the heat receiver was removed and replaced with an electrical resistance heater, simulating the thermal input of a steady-state nuclear source. The converter was operated over a full range of thermal input power levels and rotor speeds to generate an overall performance map. The converter unit will serve as the centerpiece of a Nuclear Electric Propulsion Testbed at Glenn. Future potential uses for the Testbed include high voltage electrical controller development, integrated electric thruster testing and advanced radiator demonstration testing to help guide high power Brayton technology development for Nuclear Electric Propulsion (NEP).
... Sample Required? A blood sample drawn from a vein in your arm Test Preparation Needed? None Looking ... is obtained by inserting a needle into a vein in the arm. Is any test preparation needed ...
2014-09-17
SAN DIEGO, Calif. – The Orion boilerplate test vehicle floats in the Pacific Ocean, a distance away from the USS Anchorage, during the third day of Orion Underway Recovery Test 3. The orange stabilizers inflated on top help keep the test vehicle floating upright. U.S. Navy divers in a Zodiac boat, at left, and other team members in a rigid hull inflatable boat prepare the test vehicle for return to the ship. NASA, Lockheed Martin and U.S. Navy personnel are conducting the recovery test using the test vehicle to prepare for recovery of the Orion crew module on its return from a deep space mission. The test allows the teams to demonstrate and evaluate the recovery processes, procedures, hardware and personnel in open waters. The Ground Systems Development and Operations Program is conducting the underway recovery tests. Orion is the exploration spacecraft designed to carry astronauts to destinations not yet explored by humans, including an asteroid and Mars. It will have emergency abort capability, sustain the crew during space travel and provide safe re-entry from deep space return velocities. The first unpiloted test flight of Orion is scheduled to launch in 2014 atop a United Launch Alliance Delta IV Heavy rocket and in 2018 on NASA’s Space Launch System rocket. For more information, visit http://www.nasa.gov/orion. Photo credit: NASA/Kim Shiflett
A Draft Protocol for Detecting Possible Biohazards in Martian Samples Returned to Earth
NASA Technical Reports Server (NTRS)
Viso, M.; DeVincenzi, D. L.; Race, M. S.; Schad, P. J.; Stabekis, P. D.; Acevedo, S. E.; Rummel, J. D.
2002-01-01
In preparation for missions to Mars that will involve the return of samples, it is necessary to prepare for the safe receiving, handling, testing, distributing, and archiving of martian materials here on Earth. Previous groups and committees have studied selected aspects of sample return activities, but a specific protocol for handling and testing of returned -=1 samples from Mars remained to be developed. To refine the requirements for Mars sample hazard testing and to develop criteria for the subsequent release of sample materials from precautionary containment, NASA Planetary Protection Officer, working in collaboration with CNES, convened a series of workshops to produce a Protocol by which returned martian sample materials could be assessed for biological hazards and examined for evidence of life (extant or extinct), while safeguarding the samples from possible terrestrial contamination. The Draft Protocol was then reviewed by an Oversight and Review Committee formed specifically for that purpose and composed of senior scientists. In order to preserve the scientific value of returned martian samples under safe conditions, while avoiding false indications of life within the samples, the Sample Receiving Facility (SRF) is required to allow handling and processing of the Mars samples to prevent their terrestrial contamination while maintaining strict biological containment. It is anticipated that samples will be able to be shipped among appropriate containment facilities wherever necessary, under procedures developed in cooperation with international appropriate institutions. The SRF will need to provide different types of laboratory environments for carrying out, beyond sample description and curation, the various aspects of the protocol: Physical/Chemical analysis, Life Detection testing, and Biohazard testing. The main principle of these tests will be described and the criteria for release will be discussed, as well as the requirements for the SRF and its personnel.
New vehicle based on a microemulsion for topical ocular administration of dexamethasone.
Fialho, Sílvia Ligório; da Silva-Cunha, Armando
2004-12-01
Eye drops are the most used dosage form by the ocular route, in spite of their low bioavailability. Due to their properties and numerous advantages, microemulsions are promising systems for topical ocular drug delivery. They can increase water solubility of the drug and enhance drug absorption into the eye. The present study describes the development and characterization of an oil-in-water microemulsion containing dexamethasone and the evaluation of its pharmacokinetics in rabbits after topical ocular application. The microemulsion was prepared by the titration technique. Its physico-chemical characteristics and stability were determined. The ocular irritation test and the pharmacokinetics of this system were studied in white rabbits. The developed system showed an acceptable physico-chemical behaviour and presented good stability for 3 months. The ocular irritation test used suggested that the microemulsion did not provide significant alteration to eyelids, conjunctiva, cornea and iris. This formulation showed greater penetration of dexamethasone in the anterior segment of the eye and also release of the drug for a longer time when compared with a conventional preparation. The area under the curve obtained for the microemulsion system was more than twofold higher than that of the conventional preparation (P < 0.05). The microemulsion-based dexamethasone eye drop is advantageous for ophthalmic use because it is well-tolerated in the eye and seemed to provide a higher degree of bioavailability. The developed system shows greater penetration in the eye, allowing the possibility of decreasing the number of applications of eye drops per day.
NASA Technical Reports Server (NTRS)
Sherwood, Peter M. A.; Lease, Kevin B.; Locke, James E.; Tomblin, John S.; Wang, Youqi
1996-01-01
Carbon fiber reinforced composites are materials where carbon fibers are used to reinforce a matrix to produce a light and strong material with important applications in the aerospace industry. There are many aspects of the preparation of these materials that would benefit from a study which combines the research of groups involved in the production, testing and analysis of these materials, and studies of the basic surface chemistry involved. This final reports presents the results of a project that has developed a collaboration between groups in all three of the major research universities in the State of Kansas, and promises to lead to a collaborative program that covers the major aspects of composite development and application. Sherwood has provided initial fiber surface treatment and sizing together with fiber and composite surface analysis; Lease, Tomblin and Wang have worked together toward the goal of preparing pre-preg and fabrication of laminated panels; Locke has developed computational models to evaluate the effect of surface treatment (and chemistry) on mechanical properties; Lease, Tomblin and Wang have worked together to perform all necessary mechanical testing. The research has been focused on materials that would benefit the High Speed Civil Transport (HSCT) program. The group has visited Dr. Howard Maars and his colleagues at NASA Langley, and has focused their studies on the NASA requirements discussed in this meeting. An important development, requested by NASA scientists, has been the acquisition and study of K3B as a matrix material for the composites. The project has led to the successful acquisition and surface analysis of K3B, together with the successful deposition of this material onto surface oxidized carbon fibers. Mechanical testing, modelling and the construction of composite preparation equipment has been achieved during the grant period.
Ozkan Cansel, Kose; Ozgur, Esim; Sevinc, Kurbanoglu; Ayhan, Savaser; Ozkan, Sibel A; Yalcin, Ozkan
2016-01-01
Pharmaceutical preparations of ezetimibe and atorvastatin are generally used to regulate the lipid level in blood. It decreases the secondary events for patients with high cholesterol and clinical cardiovascular disease such as non-fatal or fatal heart attack. There is no any pharmacopoeia method available for the dissolution testing recommended by the FDA. Development of dissolution tests method is very critical parameter especially for the pharmaceutical preparations that contain Class II drugs (slightly soluble, good permeable). In the proposed method, the effects of pH and surfactant on the dissolution of poorly water soluble combined drug therapy with a different pKa values in an in vitro environment is investigated. The content of our study was designed to answer these open-ended questions. The optimized test conditions achieved under sink conditions with USP apparatus 2 at a paddle rotation speed of 75 rpm and 900 ml in 0.01 M Acetate buffer (pH= 6.8) containing 0.45% SDS as a dissolution medium. Quantification of dissolution samples were analyzed with a new fully validated RP-LC method with UV detection at 242 nm.
[Diagnostic kits in parasitology: which controls?].
Rossi, P
2004-06-01
The development of new diagnostic tools particularly for some parasitic "neglected diseases", is slowed or even hindered by limited resources assigned for basic and applied research in public institution and private sector. Even if the time-line and costs needed for developing a new In Vitro Diagnostic (IVD) test are generally lower compared to vaccines or new drugs, industry is poorly engaged in investing resources due to the perception of limited markets. To accelerate the development of diagnostics for the world's most deadly diseases, the World Health Organization's (WHO) Special Programme for Research and Training in Tropical Diseases (TDR), the United Nations Development Programme, the World Bank and the Gates Foundation, last year launched a new initiative, FIND (Foundation for Innovative New Diagnostics, www.finddiagnostics.org). The aim is to "apply the latest biotechnology innovations to develop and validate affordable diagnostic tests for diseases of the developing world". Ideally, a new diagnostic test should be accurately evaluated prior to use in medical practice. The first step would be a pre-clinical evaluation, an analytic study to determine its laboratory performance. A crucial point in this phase is the calibration of reagents (antigens, antibodies, DNA probes, etc.) against a standard reference preparation. WHO, through the WHO International Laboratories for Biological Standards, "provides International Biological Reference Preparations which serve as reference sources of defined biological activity expressed in an internationally agreed unit" (www.who.int/biologicals/IBRP/index.htm). Standardization allows "comparison of biological measurements worldwide" and ensures the reliability of diagnostic procedures. These preparations are generally intended for use in the characterization of the activity of secondary reference preparations (regional, national or in-house working standards). Unfortunately, international reference standards for parasitic diseases are not available at present, except for Toxoplasma antibodies. The first international standard reagent for Anti-Toxoplasma Serum was established in 1968 and at present, an international standard reference serum, Anti-toxoplasma serum, human TOXM is available at the National Institute for Biological Standards and Control (NIBSC) in UK. Several collaborative, multicenter studies were carried out to assess the performance of different methods and commercial tests for the diagnosis of toxoplasmosis, by providing to participating laboratories a panel of well-defined sera to be tested. A four-phase process following well-accepted methodological standards for the development of diagnostics, analogous to those internationally accepted for drugs and vaccines was recently proposed. The pre-clinical evaluation, the analytic study to assess sensitivity, specificity, predictive values in laboratory (phase I), should be followed by a proof of principle study to distinguish diseased from healthy persons in easily accessible populations (phase II). The evaluation of test performance in populations of intended use (phase III), and finally the delineation of cost-effectiveness and societal impact of new tests in comparison with existing tools (phase IV) should complete the validation procedure. In this context, national regulatory agencies play a major role in pre-market approval and post-market surveillance of IVDs. The European Community in 1998 approved a directive (Directive 98/79/EC) which rules the marketing of IVD medical devices, in order to harmonise the performance levels and standards in European countries. But, among IVDs for parasitic diseases, only those to detect congenital toxoplasmosis are submitted to defined procedures to provide the verification of products before their placing on the market and the surveillance after their marketing by a notified body, which perform appropriate examinations, tests and inspections to production facilities to verify if the device meets the requirements of the directive. In U.S.A., the Food and Drug Administration (FDA), through the Office of In Vitro Diagnostic Device Evaluation and Safety (OIVD), provides a comprehensive and regulatory activity for IVDs through pre-market evaluation and post-market surveillance. In developing countries, the scarcity of resources limits the procedures through which the national control authority can assure safety, quality and efficacy of products marketed, both imported and locally manufactured.
Hypersonic research engine project. Phase 2: Aerothermodynamic integration model development
NASA Technical Reports Server (NTRS)
Jilly, L. F. (Editor)
1971-01-01
The fabrication of the various components of the HRE AIM was completed. The purge system necessary for the cavity bounded by the outer shell assembly and the outer cowl body was studied. Preparations were begun for establishing a format for test data acquisition and reduction.
48 CFR 1352.209-71 - Limitation of future contracting.
Code of Federal Regulations, 2013 CFR
2013-10-01
... feasibility, proof of design and test, or engineering of programs not yet approved for acquisition or... computer software; and may appear in cost and pricing data or involve classified information. (iv) “System...'s development, production, or support. (vi) “Systems Engineering” means preparing specifications...
48 CFR 1352.209-71 - Limitation of future contracting.
Code of Federal Regulations, 2012 CFR
2012-10-01
... feasibility, proof of design and test, or engineering of programs not yet approved for acquisition or... computer software; and may appear in cost and pricing data or involve classified information. (iv) “System...'s development, production, or support. (vi) “Systems Engineering” means preparing specifications...
48 CFR 1352.209-71 - Limitation of future contracting.
Code of Federal Regulations, 2014 CFR
2014-10-01
... feasibility, proof of design and test, or engineering of programs not yet approved for acquisition or... computer software; and may appear in cost and pricing data or involve classified information. (iv) “System...'s development, production, or support. (vi) “Systems Engineering” means preparing specifications...
Development of space-stable thermal control coatings for use on large space vehicles
NASA Technical Reports Server (NTRS)
Gilligan, J. E.; Harada, Y.
1976-01-01
The potential of zinc orthotitanate as a pigment for spacecraft thermal control was demonstrated. The properties and performance of pigments prepared by solid state, coprecipitation, and mixed oxalate methods were compared. Environmental tests and subsequent spectral analysis were given primary emphasis.
A Survey of Cyber Ranges and Testbeds
2013-10-01
used in organisations is large and growing. The literature indicated that cyber test labs (not explicitly called CRs) have been developed for a... organisation requires a realistic training and proving ground to prepare and conduct military CNO. That is, they need a CR. Operational networks are... developed by the Pacific Northwest National Laboratory (PNNL) to simulate the network environment of many DoD organisations . Its main capabilities
Preparation and Characterization of Fine-Particle NTO and Its Formulation with Al Nanopowders
NASA Astrophysics Data System (ADS)
Lee, K.-Y.; Kennedy, J. E.; Asay, B. W.; Son, S. F.; Martin, E. S.
2004-07-01
We have initiated study of the effect of nano-aluminum on the detonation performance of NTO. A novel method for the preparation of both fine-particle NTO (UF-NTO) and its formulation with Al nanopowder has been developed. Results from small-scale sensitivity tests on both the UF-NTO and aluminized NTO composite indicated that they are insensitive to impact, friction and HESD. The performance of both UF-NTO and NTO/Al mix was evaluated by detonation-spreading floret tests. At the same pressed density, it was found that, when initiated by a 3-mm-diameter flyer plate, the aluminized NTO composite produced a shallower dent on a copper witness plate than neat UF-NTO and thus was inferior to UF-NTO in detonation spreading.
Obaidat, Rana M; Bader, Ammar; Al-Rajab, Wafa; Abu Sheikha, Ghassan; Obaidat, Aiman A
2011-01-01
The specific aim of this work was to prepare mucoadhesive patches containing tetracycline hydrochloride and carvacrol in an attempt to develop a novel oral drug delivery system for the treatment of mouth infections. The bilayered patches were prepared using ethyl cellulose as a backing layer and carbopol 934 as a matrix mucoadhesive layer. Patches were prepared with different loading amounts of tetracycline hydrochloride and carvacrol. The antimicrobial activity was assessed for the prepared patches using the disc-diffusion method against the yeast Candida albicans and five bacterial strains, including Pseudomonas aeruginosa, Escherichia coli, Bacillus cereus, Staphylococcus aureus, and Bacillus bronchispti. In this work, we highlighted the possibility of occurrence of a synergistic action between carvacrol and tetracycline. The best formulation was selected based on microbiological tests, drug release, ex-vivo mucoadhesive performance, and swelling index. Physical characteristics of the selected formulations were determined. These included pH, patch thickness, weight uniformity, content uniformity, folding endurance, and patch stability.
Rapid Automated Sample Preparation for Biological Assays
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shusteff, M
Our technology utilizes acoustic, thermal, and electric fields to separate out contaminants such as debris or pollen from environmental samples, lyse open cells, and extract the DNA from the lysate. The objective of the project is to optimize the system described for a forensic sample, and demonstrate its performance for integration with downstream assay platforms (e.g. MIT-LL's ANDE). We intend to increase the quantity of DNA recovered from the sample beyond the current {approx}80% achieved using solid phase extraction methods. Task 1: Develop and test an acoustic filter for cell extraction. Task 2: Develop and test lysis chip. Task 3:more » Develop and test DNA extraction chip. All chips have been fabricated based on the designs laid out in last month's report.« less
... transport the sample from home to the lab. Examples of some common laboratory tests that require advance preparation include: Glucose tolerance, fasting, and two-hour post-prandial blood glucose tests : fasting or eating meals ...
Training in multiple breath washout testing for respiratory physiotherapists.
O'Neill, Katherine; Elborn, J Stuart; Tunney, Michael M; O'Neill, Philip; Rowan, Stephen; Martin, Susan; Bradley, Judy M
2018-03-01
The development of multiple breath washout (MBW) testing in respiratory disease highlights the need for increased awareness amongst respiratory physiotherapists and a potential opportunity for professional development in the use of an important outcome measure for clinical trials. To rationalise how MBW may be a useful assessment tool for respiratory physiotherapists and to describe a local MBW training and certification programme for physiotherapists. The respiratory Multidisciplinary Team in the Belfast Health and Social Care Trust (BHSCT) identified a need for MBW testing to be available to facilitate clinical research and assessment. A 2day training programme consisting of prereading preparation, self-directed learning, theory presentations, practical demonstrations and hands-on practice was developed and delivered. All participants underwent a certification process. We have demonstrated the successful training and certification of clinical and research physiotherapists and encourage other respiratory physiotherapists to consider MBW test training. Copyright © 2017 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Wittmann, A.; Willay, G.
1986-01-01
For a rapid preparation of solutions intended for analysis by inductively coupled plasma emission spectrometry or atomic absorption spectrometry, an automatic device called Plasmasol was developed. This apparatus used the property of nonwettability of glassy C to fuse the sample in an appropriate flux. The sample-flux mixture is placed in a composite crucible, then heated at high temperature, swirled until full dissolution is achieved, and then poured into a water-filled beaker. After acid addition, dissolution of the melt, and filling to the mark, the solution is ready for analysis. The analytical results obtained, either for oxide samples or for prereduced iron ores show that the solutions prepared with this device are undistinguished from those obtained by manual dissolutions done by acid digestion or by high temperature fusion. Preparation reproducibility and analytical tests illustrate the performance of Plasmasol.
Fabrication of GaAs symmetric pyramidal mesas prepared by wet-chemical etching using AlAs interlayer
NASA Astrophysics Data System (ADS)
Kicin, S.; Cambel, V.; Kuliffayová, M.; Gregušová, D.; Kováčová, E.; Novák, J.; Kostič, I.; Förster, A.
2002-01-01
We present a wet-chemical-etching method developed for the preparation of GaAs four-sided pyramid-shaped mesas. The method uses a fast lateral etching of AlAs interlayer that influences the cross-sectional profiles of etched structures. We have tested the method using H3PO4:H2O2:H2O etchant for the (100) GaAs patterning. The sidewalls of the prepared pyramidal structures together with the (100) bottom facet formed the cross-sectional angles 25° and 42° for mask edges parallel, resp. perpendicular to {011} cleavage planes. For mask edges turned in 45° according to the cleavage planes, 42° cross-sectional angles were obtained. Using the method, symmetric and more than 10-μm-high GaAs "Egyptian" pyramids with smooth tilted facets were prepared.
2014-09-15
SAN DIEGO, Calif. – Helicopter Sea Combat Squadron 8, or HSC 8, prepare two H60-S helicopters for flight on the deck of the USS Anchorage during the first day of Orion Underway Recovery Test 3. The helicopters will be used during recovery of the Orion boilerplate test article. NASA, Lockheed Martin and U.S. Navy personnel are conducting recovery tests to prepare for recovery of the Orion crew module on its return from a deep space mission. The test will allow the teams to demonstrate and evaluate the recovery processes, procedures, hardware and personnel in open waters. The Ground Systems Development and Operations Program is conducting the underway recovery tests. Orion is the exploration spacecraft designed to carry astronauts to destinations not yet explored by humans, including an asteroid and Mars. It will have emergency abort capability, sustain the crew during space travel and provide safe re-entry from deep space return velocities. The first unpiloted test flight of Orion is scheduled to launch in 2014 atop a United Launch Alliance Delta IV Heavy rocket and in 2018 on NASA’s Space Launch System rocket. For more information, visit http://www.nasa.gov/orion. Photo credit: NASA/Cory Huston
EU Regulation of Nanobiocides: Challenges in Implementing the Biocidal Product Regulation (BPR)
Brinch, Anna; Hansen, Steffen Foss; Hartmann, Nanna B.; Baun, Anders
2016-01-01
The Biocidal Products Regulation (BPR) contains several provisions for nanomaterials (NMs) and is the first regulation in the European Union to require specific testing and risk assessment for the NM form of a biocidal substance as a part of the information requirements. Ecotoxicological data are one of the pillars of the information requirements in the BPR, but there are currently no standard test guidelines for the ecotoxicity testing of NMs. The overall objective of this work was to investigate the implications of the introduction of nano-specific testing requirements in the BPR and to explore how these might be fulfilled in the case of copper oxide nanoparticles. While there is information and data available in the open literature that could be used to fulfill the BPR information requirements, most of the studies do not take the Organisation for Economic Co-operation and Development’s nanospecific test guidelines into consideration. This makes it difficult for companies as well as regulators to fulfill the BPR information requirements for nanomaterials. In order to enable a nanospecific risk assessment, best practices need to be developed regarding stock suspension preparation and characterization, exposure suspensions preparation, and for conducting ecotoxicological test. PMID:28344290
2013-12-06
CAPE CANAVERAL, Fla. – At NASA’s Kennedy Space Center in Florida, the Project Morpheus prototype lander has been attached to a tether and is being prepared for placement on a transportable launch platform positioned at the north end of the Shuttle Landing Facility. The lander will be prepared for a tethered test that includes lifting it 20 feet by crane, ascending another 10 feet, maneuvering backwards 10 feet, and then flying forward and descending to its original position, landing at the end of the tether. Testing of the prototype lander was performed at NASA’s Johnson Space Center in Houston in preparation for tethered and free flight testing at Kennedy. The landing facility will provide the lander with the kind of field necessary for realistic testing, complete with rocks, craters and hazards to avoid. Morpheus utilizes an autonomous landing and hazard avoidance technology, or ALHAT, payload that will allow it to navigate to clear landing sites amidst rocks, craters and other hazards during its descent. Project Morpheus is being managed under the Advanced Exploration Systems, or AES, Division in NASA’s Human Exploration and Operations Mission Directorate. The efforts in AES pioneer new approaches for rapidly developing prototype systems, demonstrating key capabilities and validating operational concepts for future human missions beyond Earth orbit. For more information on Project Morpheus, visit http://morpheuslander.jsc.nasa.gov. Photo credit: NASA/Kim Shiflett
Baseline LAW Glass Formulation Testing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kruger, Albert A.; Mooers, Cavin; Bazemore, Gina
2013-06-13
The major objective of the baseline glass formulation work was to develop and select glass formulations that are compliant with contractual and processing requirements for each of the LAW waste streams. Other objectives of the work included preparation and characterization of glasses with respect to the properties of interest, optimization of sulfate loading in the glasses, evaluation of ability to achieve waste loading limits, testing to demonstrate compatibility of glass melts with melter materials of construction, development of glass formulations to support ILAW qualification activities, and identification of glass formulation issues with respect to contract specifications and processing requirements.
Brne, P; Lim, Y-P; Podgornik, A; Barut, M; Pihlar, B; Strancar, A
2009-03-27
Convective interaction media (CIM; BIA Separations) monoliths are attractive stationary phases for use in affinity chromatography because they enable fast affinity binding, which is a consequence of convectively enhanced mass transport. This work focuses on the development of novel CIM hydrazide (HZ) monoliths for the oriented immobilization of antibodies. Adipic acid dihydrazide (AADH) was covalently bound to CIM epoxy monoliths to gain hydrazide groups on the monolith surface. Two different antibodies were afterwards immobilized to hydrazide functionalized monolithic columns and prepared columns were tested for their selectivity. One column was further tested for the dynamic binding capacity.
Development of advanced fuel cell system
NASA Technical Reports Server (NTRS)
Grevstad, P. E.
1972-01-01
Weight, life and performance characteristics optimization of hydrogen-oxygen fuel cell power systems were considered. A promising gold alloy cathode catalyst was identified and tested in a cell for 5,000 hours. The compatibility characteristics of candidate polymer structural materials were measured after exposure to electrolyte and water vapor for 8,000 hours. Lightweight cell designs were prepared and fabrication techniques to produce them were developed. Testing demonstrated that predicted performance was achieved. Lightweight components for passive product water removal and evaporative cooling of cells were demonstrated. Systems studies identified fuel cell powerplant concepts for meeting the requirements of advanced spacecraft.