Uchida, Takahiro; Ikeno, Fumiaki; Ikeda, Koji; Suzuki, Yuka; Todaka, Koji; Yokoi, Hiroyoshi; Thompson, Gary; Krucoff, Mitchel; Saito, Shigeru
2013-01-01
Global medical devices have become more popular, but investment money for medical device development is not easily available in the market. Worldwide health-care budget constraints mean that efficient medical device development has become essential. To achieve efficient development, globalization is a key to success. Spending large amounts of money in different regions for medical device development is no longer feasible. In order to streamline processes of global medical device development, an academic, governmental, and industrial consortium, called the Harmonization by Doing program, has been set up. The program has been operating between Japan and the USA since 2003. The program has 4 working groups: (1) Global Cardiovascular Device Trials; (2) Study on Post-Market Registry; (3) Clinical Trials; and (4) Infrastructure and Methodology Regulatory Convergence and Communication. Each working group has as its goals the achievement of speedy and efficient medical device development in Japan and the USA. The program has held multiple international meetings to deal with obstacles against efficient medical device development. This kind of program is very important to deliver novel medical devices. Involvement of physicians in this type of activity is also very helpful to achieve these goals.
Multidisciplinary collaboration as a sustainable research model for device development.
Chandra, Ankur
2013-02-01
The concurrent problems of research sustainability and decreased clinician involvement with medical device development can be jointly addressed through a novel, multidisciplinary solution. The University of Rochester Cardiovascular Device Design Program is a sustainable program in medical device design supported through a collaboration between the Schools of Medicine and Engineering. This article provides a detailed description of the motivation for starting the program, the current structure of the program, the methods of financial sustainability, and the direct impact it intends to have on the national vascular surgery community. The further expansion of this program and encouragement for development of similar programs throughout the country aims to address many of our current challenges in both research funding and device development education. Copyright © 2013 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.
Research on Synthetic Training: Device Evaluation and Training Program Development.
ERIC Educational Resources Information Center
Caro, Paul W.; And Others
Two studies were conducted to evaluate a fixed-wing instrument procedures training device and to develop a training program for use with it. In the first, a group of trainees who received synthetic instrument flight training with the new device were compared with a control group who did not. Men trained with the device performed more…
78 FR 20665 - Pediatric Device Consortia Grant Program
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-05
... population (neonates, infants, children, and adolescents) includes patients who are 21 years of age or... of the Office of Orphan Products Development (OOPD) Pediatric Device Consortia (PDC) Grant Program. The goal of the PDC Grant Program is to facilitate the development, production, and distribution of...
Device-tissue interactions: a collaborative communications system.
Chekan, Edward; Whelan, Richard L; Feng, Alexander H
2013-07-29
Medical devices, including surgical staplers, energy-based devices, and access enabling devices, are used routinely today in the majority of surgical procedures. Although these technically advanced devices have proved to be of immense benefit to both surgeons and patients, their rapid development and continuous improvement have had the unintended consequence of creating a knowledge gap for surgeons due to a lack of adequate training and educational programs. Thus, there is an unmet need in the surgical community to collect existing data on device-tissue interactions and subsequently develop research and educational programs to fill this gap in surgical training. Gathering data and developing these new programs will require collaboration between doctors, engineers, and scientists, from both clinical practice and industry. This paper presents a communications system to enable this unique collaboration that can potentially result in significantly improved patient care.
Pediatric medical device development by surgeons via capstone engineering design programs.
Sack, Bryan S; Elizondo, Rodolfo A; Huang, Gene O; Janzen, Nicolette; Espinoza, Jimmy; Sanz-Cortes, Magdalena; Dietrich, Jennifer E; Hakim, Julie; Richardson, Eric S; Oden, Maria; Hanks, John; Haridas, Balakrishna; Hury, James F; Koh, Chester J
2018-03-01
There is a need for pediatric medical devices that accommodate the unique physiology and anatomy of pediatric patients that is increasingly receiving more attention. However, there is limited literature on the programs within children's hospitals and academia that can support pediatric device development. We describe our experience with pediatric device design utilizing collaborations between a children's hospital and two engineering schools. Utilizing the academic year as a timeline, unmet pediatric device needs were identified by surgical faculty and matched with an engineering mentor and a team of students within the Capstone Engineering Design programs at two universities. The final prototypes were showcased at the end of the academic year and if appropriate, provisional patent applications were filed. All twelve teams successfully developed device prototypes, and five teams obtained provisional patents. The prototypes that obtained provisional patents included a non-operative ureteral stent removal system, an evacuation device for small kidney stone fragments, a mechanical leech, an anchoring system of the chorio-amniotic membranes during fetal surgery, and a fetal oxygenation monitor during fetoscopic procedures. Capstone Engineering Design programs in partnership with surgical faculty at children's hospitals can play an effective role in the prototype development of novel pediatric medical devices. N/A - No clinical subjects or human testing was performed. Copyright © 2017 Elsevier Inc. All rights reserved.
Sezdi, Mana
2016-01-01
A maintenance program generated through the consideration of characteristics and failures of medical equipment is an important component of technology management. However, older technology devices and newer high-tech devices cannot be efficiently managed using the same strategies because of their different characteristics. This study aimed to generate a maintenance program comprising two different strategies to increase the efficiency of device management: preventive maintenance for older technology devices and predictive maintenance for newer high-tech devices. For preventive maintenance development, 589 older technology devices were subjected to performance verification and safety testing (PVST). For predictive maintenance development, the manufacturers' recommendations were used for 134 high-tech devices. These strategies were evaluated in terms of device reliability. This study recommends the use of two different maintenance strategies for old and new devices at hospitals in developing countries. Thus, older technology devices that applied only corrective maintenance will be included in maintenance like high-tech devices.
Sezdi, Mana
2016-01-01
A maintenance program generated through the consideration of characteristics and failures of medical equipment is an important component of technology management. However, older technology devices and newer high-tech devices cannot be efficiently managed using the same strategies because of their different characteristics. This study aimed to generate a maintenance program comprising two different strategies to increase the efficiency of device management: preventive maintenance for older technology devices and predictive maintenance for newer high-tech devices. For preventive maintenance development, 589 older technology devices were subjected to performance verification and safety testing (PVST). For predictive maintenance development, the manufacturers' recommendations were used for 134 high-tech devices. These strategies were evaluated in terms of device reliability. This study recommends the use of two different maintenance strategies for old and new devices at hospitals in developing countries. Thus, older technology devices that applied only corrective maintenance will be included in maintenance like high-tech devices. PMID:27195666
Flexible Architecture for FPGAs in Embedded Systems
NASA Technical Reports Server (NTRS)
Clark, Duane I.; Lim, Chester N.
2012-01-01
Commonly, field-programmable gate arrays (FPGAs) being developed in cPCI embedded systems include the bus interface in the FPGA. This complicates the development because the interface is complicated and requires a lot of development time and FPGA resources. In addition, flight qualification requires a substantial amount of time be devoted to just this interface. Another complication of putting the cPCI interface into the FPGA being developed is that configuration information loaded into the device by the cPCI microprocessor is lost when a new bit file is loaded, requiring cumbersome operations to return the system to an operational state. Finally, SRAM-based FPGAs are typically programmed via specialized cables and software, with programming files being loaded either directly into the FPGA, or into PROM devices. This can be cumbersome when doing FPGA development in an embedded environment, and does not have an easy path to flight. Currently, FPGAs used in space applications are usually programmed via multiple space-qualified PROM devices that are physically large and require extra circuitry (typically including a separate one-time programmable FPGA) to enable them to be used for this application. This technology adds a cPCI interface device with a simple, flexible, high-performance backend interface supporting multiple backend FPGAs. It includes a mechanism for programming the FPGAs directly via the microprocessor in the embedded system, eliminating specialized hardware, software, and PROM devices and their associated circuitry. It has a direct path to flight, and no extra hardware and minimal software are required to support reprogramming in flight. The device added is currently a small FPGA, but an advantage of this technology is that the design of the device does not change, regardless of the application in which it is being used. This means that it needs to be qualified for flight only once, and is suitable for one-time programmable devices or an application specific integrated circuit (ASIC). An application programming interface (API) further reduces the development time needed to use the interface device in a system.
Le, Tran T
2017-01-01
Over 30 years ago, the United States (US) Congress passed the Orphan Drug Act (ODA) to encourage the development of products for rare diseases or conditions ("orphan products"). The Act provided incentives to sponsors for developing products with orphan designation and established a grant program to fund studies of orphan products. Since its enactment in 1983, the ODA has been credited for bringing more than 590 orphan drugs to the market, inspiring the implementation of orphan legislation globally, and enabling the creation of other programs that extend existing knowledge of the natural history of rare diseases and stimulate the development of medical devices for children and patients with rare diseases. This chapter provides a brief overview of the main features and successes of 5 of the orphan incentive programs administered by the US Food and Drug Administration (FDA): the Orphan Drug Designation Program, the Humanitarian Use Device (HUD) Designation Program, the Orphan Products Clinical Trials Grants Program, the Pediatric Device Consortia (PDC) Grant Program, and the Orphan Products Natural History Grants Program.
ERIC Educational Resources Information Center
Minnesota Department of Education, 2016
2016-01-01
As required by Minnesota 2015 Special Session Law, House File 1, Article 6, Section 8, the commissioner of Education must research existing one device to one student (1:1) device programs in Minnesota and across the country to determine best practices for Minnesota schools implementing 1:1 device programs. The commissioner must develop and publish…
76 FR 3145 - Pediatric Device Consortia Grant Program (P50)
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-19
... use in children. The program does not support the development of single device projects. Although... population (neonates, infants, children, and adolescents) includes patients who are 21 years of age or... adults. Children differ from adults in terms of their size, growth, development, and body chemistry...
Photonics: Technology project summary
NASA Technical Reports Server (NTRS)
Depaula, Ramon P.
1991-01-01
Photonics involves the use of light (photons) in conjunction with electronics for applications in communications, computing, control, and sensing. Components used in photonic systems include lasers, optical detectors, optical wave guide devices, fiber optics, and traditional electronic devices. The goal of this program is to develop hybrid optoelectronic devices and systems for sensing, information processing, communications, and control. It is hoped that these new devices will yield at least an order of magnitude improvement in performance over existing technology. The objective of the program is to conduct research and development in the following areas: (1) materials and devices; (2) networking and computing; (3) optical processing/advanced pattern recognition; and (4) sensing.
Single-Event Effects in Silicon Carbide Power Devices
NASA Technical Reports Server (NTRS)
Lauenstein, Jean-Marie; Casey, Megan C.; LaBel, Kenneth A.; Ikpe, Stanley; Topper, Alyson D.; Wilcox, Edward P.; Kim, Hak; Phan, Anthony M.
2015-01-01
This report summarizes the NASA Electronic Parts and Packaging Program Silicon Carbide Power Device Subtask efforts in FY15. Benefits of SiC are described and example NASA Programs and Projects desiring this technology are given. The current status of the radiation tolerance of silicon carbide power devices is given and paths forward in the effort to develop heavy-ion single-event effect hardened devices indicated.
A flexible microcontroller-based data acquisition device.
Hercog, Darko; Gergič, Bojan
2014-06-02
This paper presents a low-cost microcontroller-based data acquisition device. The key component of the presented solution is a configurable microcontroller-based device with an integrated USB transceiver and a 12-bit analogue-to-digital converter (ADC). The presented embedded DAQ device contains a preloaded program (firmware) that enables easy acquisition and generation of analogue and digital signals and data transfer between the device and the application running on a PC via USB bus. This device has been developed as a USB human interface device (HID). This USB class is natively supported by most of the operating systems and therefore any installation of additional USB drivers is unnecessary. The input/output peripheral of the presented device is not static but rather flexible, and could be easily configured to customised needs without changing the firmware. When using the developed configuration utility, a majority of chip pins can be configured as analogue input, digital input/output, PWM output or one of the SPI lines. In addition, LabVIEW drivers have been developed for this device. When using the developed drivers, data acquisition and signal processing algorithms as well as graphical user interface (GUI), can easily be developed using a well-known, industry proven, block oriented LabVIEW programming environment.
TEACHING MACHINES AND PROGRAMMED LEARNING, A SOURCE BOOK.
ERIC Educational Resources Information Center
LUMSDAINE, A.A., ED.; GLASER, ROBERT, ED.
BROUGHT TOGETHER HERE IS THE WIDELY-SCATTERED LITERATURE ON SELF-INSTRUCTIONAL PROGRAMS AND DEVICES BY LEADERS, PAST AND PRESENT, IN THEIR DEVELOPMENT. S.L. PRESSEY IN HIS ARTICLES DESCRIBES THE APPARATUS, METHODS, THEORY, AND RESULTS ATTENDANT UPON USE OF HIS TEST-SCORING DEVICES. B.F. SKINNER IN HIS ARTICLES DEVELOPS THEORY, DESCRIBES MACHINES,…
A Combined Research/Educational Curriculum in Smart Sensors and Integrated Devices.
ERIC Educational Resources Information Center
Auner, G. W.; Siy, P.; Naik, R.; Wenger, L.; Liu, G-Y.; Schwiebert, L. J.
The researchers are developing a new curriculum which integrates ongoing research efforts in the Center for Smart Sensors and Integrated Devices into a cooperative educational and traineeship program. A forerunner to this program was initiated with funding by a National Science Foundation (NSF) Combined Research and Curriculum Development (CRCD)…
Tierless Programming for the Internet of Things
DOE Office of Scientific and Technical Information (OSTI.GOV)
Decker, Brett
The Internet of Things (IoT) is about Internet-addressability and connectivity for everyday devices. The goal of this project was to create a framework to allow developers to more easily control IoT devices and turn their interactions into meaningful applications. We leveraged a tierless approach for Software Defined Networking (SDN) to build this framework. We expanded Flowlog, a tierless programming language for SDN controllers, to support IoT devices developed by Spark IO to build this framework.
Vacuum status-display and sector-conditioning programs
NASA Astrophysics Data System (ADS)
Skelly, J.; Yen, S.
1990-08-01
Two programs have been developed for observation and control of the AGS vacuum system, which include the following notable features: (1) they incorporate a graphical user interface and (2) they are driven by a relational database which describes the vacuum system. The vacuum system comprises some 440 devices organized into 28 vacuum sectors. The status-display program invites menu selection of a sector, interrogates the relational database for relevant vacuum devices, acquires live readbacks and posts a graphical display of their status. The sector-conditioning program likewise invites sector selection, produces the same status display and also implements process control logic on the sector devices to pump the sector down from atmospheric pressure to high vacuum over a period extending several hours. As additional devices are installed in the vacuum system, the devices are added to the relational database; these programs then automatically include the new devices.
Development of a laboratory demonstration model active cleaning device
NASA Technical Reports Server (NTRS)
Shannon, R. L.; Gillette, R. B.
1975-01-01
A laboratory demonstration model of a device for removing contaminant films from optical surfaces in space was developed. The development of a plasma tube, which would produce the desired cleaning effects under high vacuum conditions, represented the major problem in the program. This plasma tube development is discussed, and the resulting laboratory demonstration-model device is described.
Application and Design Characteristics of Generalized Training Devices.
ERIC Educational Resources Information Center
Parker, Edward L.
This program identified applications and developed design characteristics for generalized training devices. The first of three sequential phases reviewed in detail new developments in Naval equipment technology that influence the design of maintenance training devices: solid-state circuitry, modularization, digital technology, standardization,…
A Flexible Microcontroller-Based Data Acquisition Device
Hercog, Darko; Gergič, Bojan
2014-01-01
This paper presents a low-cost microcontroller-based data acquisition device. The key component of the presented solution is a configurable microcontroller-based device with an integrated USB transceiver and a 12-bit analogue-to-digital converter (ADC). The presented embedded DAQ device contains a preloaded program (firmware) that enables easy acquisition and generation of analogue and digital signals and data transfer between the device and the application running on a PC via USB bus. This device has been developed as a USB human interface device (HID). This USB class is natively supported by most of the operating systems and therefore any installation of additional USB drivers is unnecessary. The input/output peripheral of the presented device is not static but rather flexible, and could be easily configured to customised needs without changing the firmware. When using the developed configuration utility, a majority of chip pins can be configured as analogue input, digital input/output, PWM output or one of the SPI lines. In addition, LabVIEW drivers have been developed for this device. When using the developed drivers, data acquisition and signal processing algorithms as well as graphical user interface (GUI), can easily be developed using a well-known, industry proven, block oriented LabVIEW programming environment. PMID:24892494
Multi-junction Thin-film Solar Cells on Flexible Substrates for Space Power
NASA Technical Reports Server (NTRS)
Hepp, Aloysius F.; Smith, Mark; Scofield, John H.; Dickman, John E.; Lush, Gregory B.; Morel, Donald L.; Ferekides, Christos; Dhere, Neelkanth G.
2002-01-01
The ultimate objective of the thin-film program at NASA GRC is development of a 20 percent AM0 thin-film device technology with high power/weight ratio. Several approaches are outlined to improve overall device efficiency and power/weight ratio. One approach involves the use of very lightweight flexible substrates such as polyimides (i.e., Kapton(Trademark)) or metal foil. Also, a compound semiconductor tandem device structure that can meet this objective is proposed and simulated using Analysis of Microelectronic and Photonic Structures (AMPS). AMPS modeling of current devices in tandem format indicate that AM0 efficiencies near 20 percent can be achieved. And with improvements in materials, efficiencies approaching 25 percent are achievable. Several important technical issues need to be resolved to realize these complex devices: development of a wide bandgap material with good electronic properties, development of transparent contacts, and targeting a 2-terminal device structure (with more complicated processing and tunnel junction) or 4-terminal device. Recent progress in the NASA GRC program is outlined.
Determining Training Device Requirements in Army Aviation Systems
NASA Technical Reports Server (NTRS)
Poumade, M. L.
1984-01-01
A decision making methodology which applies the systems approach to the training problem is discussed. Training is viewed as a total system instead of a collection of individual devices and unrelated techniques. The core of the methodology is the use of optimization techniques such as the transportation algorithm and multiobjective goal programming with training task and training device specific data. The role of computers, especially automated data bases and computer simulation models, in the development of training programs is also discussed. The approach can provide significant training enhancement and cost savings over the more traditional, intuitive form of training development and device requirements process. While given from an aviation perspective, the methodology is equally applicable to other training development efforts.
UWALK: the development of a multi-strategy, community-wide physical activity program.
Jennings, Cally A; Berry, Tanya R; Carson, Valerie; Culos-Reed, S Nicole; Duncan, Mitch J; Loitz, Christina C; McCormack, Gavin R; McHugh, Tara-Leigh F; Spence, John C; Vallance, Jeff K; Mummery, W Kerry
2017-03-01
UWALK is a multi-strategy, multi-sector, theory-informed, community-wide approach using e and mHealth to promote physical activity in Alberta, Canada. The aim of UWALK is to promote physical activity, primarily via the accumulation of steps and flights of stairs, through a single over-arching brand. This paper describes the development of the UWALK program. A social ecological model and the social cognitive theory guided the development of key strategies, including the marketing and communication activities, establishing partnerships with key stakeholders, and e and mHealth programs. The program promotes the use of physical activity monitoring devices to self-monitor physical activity. This includes pedometers, electronic devices, and smartphone applications. In addition to entering physical activity data manually, the e and mHealth program provides the function for objective data to be automatically uploaded from select electronic devices (Fitbit®, Garmin and the smartphone application Moves) The RE-AIM framework is used to guide the evaluation of UWALK. Funding for the program commenced in February 2013. The UWALK brand was introduced on April 12, 2013 with the official launch, including the UWALK website on September 20, 2013. This paper describes the development and evaluation framework of a physical activity promotion program. This program has the potential for population level dissemination and uptake of an ecologically valid physical activity promotion program that is evidence-based and theoretically framed.
Programming methodology for a general purpose automation controller
NASA Technical Reports Server (NTRS)
Sturzenbecker, M. C.; Korein, J. U.; Taylor, R. H.
1987-01-01
The General Purpose Automation Controller is a multi-processor architecture for automation programming. A methodology has been developed whose aim is to simplify the task of programming distributed real-time systems for users in research or manufacturing. Programs are built by configuring function blocks (low-level computations) into processes using data flow principles. These processes are activated through the verb mechanism. Verbs are divided into two classes: those which support devices, such as robot joint servos, and those which perform actions on devices, such as motion control. This programming methodology was developed in order to achieve the following goals: (1) specifications for real-time programs which are to a high degree independent of hardware considerations such as processor, bus, and interconnect technology; (2) a component approach to software, so that software required to support new devices and technologies can be integrated by reconfiguring existing building blocks; (3) resistance to error and ease of debugging; and (4) a powerful command language interface.
Heavy vehicle driver workload assessment : executive summary
DOT National Transportation Integrated Search
1996-10-01
This report summarizes a program of research to develop methods, data, and guidelines to conduct heavy vehicle driver-oriented workload assessments of new, high-technology, in-cab devices. Many such devices are being developed and implemented in heav...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-11
... adults. Children differ from adults in terms of their size, growth, development, and body chemistry... devices designed specifically with children in mind. Such needs include the original development of...
Crystal growth of device quality GaAs in space
NASA Technical Reports Server (NTRS)
Gatos, H. C.; Lagowski, J.
1984-01-01
The crystal growth, device processing and device related properties and phenomena of GaAs are investigated. Our GaAs research evolves about these key thrust areas. The overall program combines: (1) studies of crystal growth on novel approaches to engineering of semiconductor materials (i.e., GaAs and related compounds); (2) investigation and correlation of materials properties and electronic characteristics on a macro- and microscale; (3) investigation of electronic properties and phenomena controlling device applications and device performance. The ground based program is developed which would insure successful experimentation with and eventually processing of GaAs in a near zero gravity environment.
Integration of a mechanical forebody vortex control system into the F-15
NASA Technical Reports Server (NTRS)
Boalbey, Richard E.; Citurs, Kevin D.; Ely, Wayne L.; Harbaugh, Stephen P.; Hollingsworth, William B.; Phillips, Ronald L.
1994-01-01
The goal of the F-15 Forebody Vortex Control (FVC) program is to develop a production FVC system for the F-15. The system may consist of either a mechanically actuated device such as the strakes developed for the HARV program, or a pneumatic device such as the port blowing system being tested on the X-29. Both types of systems are being evaluated under this program. Background information on the F-15 and a description and overview of forebody vortex controls (FVC) will be presented.
Data storage technology: Hardware and software, Appendix B
NASA Technical Reports Server (NTRS)
Sable, J. D.
1972-01-01
This project involves the development of more economical ways of integrating and interfacing new storage devices and data processing programs into a computer system. It involves developing interface standards and a software/hardware architecture which will make it possible to develop machine independent devices and programs. These will interface with the machine dependent operating systems of particular computers. The development project will not be to develop the software which would ordinarily be the responsibility of the manufacturer to supply, but to develop the standards with which that software is expected to confirm in providing an interface with the user or storage system.
Program for the exploitation of unused NASA patents
NASA Technical Reports Server (NTRS)
Fay, R. J.
1972-01-01
The program to exploit unused NASA patents through the use of a multidisciplinary approach involving faculty students, and research staff is reported. NASA patents were screened for their applicability outside the space program, specific applications were identified, and the technical and commercial feasibility of these applications was established. Also application of this technology by governmental agencies outside the space program was sought. The program was specifically interested in energy absorbing devices such as those developed for lunar soft landings. These energy absorbing devices absorb large amounts of mechanical energy but are, in general, not reusable. Some of these devices can also operate as structural elements until their structural load capacity is exceeded and they become activated as energy absorbers. The capability of these devices to operate as structural elements and as energy absorbing devices makes them candidates for many applications in the fields of transportation and materials handling safety where accidents take a large toll in human injury and property damage.
1985-12-01
development of an improved Universal Network Interface Device (UNID II). The UNID II’s architecture was based on a preliminary design project at...interface device, performing all functions required ,: the multi-ring LAN. The device depicted by RADC’s studies would connect a highly variable group of host...used the ISO Open Systems Ilterconnection (OSI) seven layer model as the basic structure for data flow and program development . In 1982 Cuomo
Suppression of combustion oscillations with mechanical damping devices
NASA Technical Reports Server (NTRS)
1971-01-01
Nonarray absorbing devices were investigated for use in rocket thrust chambers as instability suppressors. A theory for designing absorbing devices suitable for rocket application is derived, and a nonarray computer program is developed. The experimental program used to verify the theory is discussed. It is concluded that individual acoustical devices can be designed for maximum energy absorption, and it is recommended that single resonators be designed so that the ratio of the aperture diameter to the product of the quarter-wave length and cavity backing depth is less than one.
NASA Technical Reports Server (NTRS)
Matus, Lawrence G.; Seng, Gary T.
1990-01-01
To meet the needs of the aerospace propulsion and space power communities, the high temperature electronics program at the Lewis Research Center is developing silicon carbide (SiC) as a high temperature semiconductor material. This program supports a major element of the Center's mission - to perform basic and developmental research aimed at improving aerospace propulsion systems. Research is focused on developing the crystal growth, characterization, and device fabrication technologies necessary to produce a family of SiC devices.
Universal programming interface with concurrent access
DOE Office of Scientific and Technical Information (OSTI.GOV)
Alferov, Oleg
2004-10-07
There exist a number of devices with a positioning nature of operation, such as mechanical linear stages, temperature controllers, or filterwheels with discrete state, and most of them have different programming interfaces. The Universal Positioner software suggests the way to handle all of them is with a single approach, whereby a particular hardware driver is created from the template and by translating the actual commands used by the hardware to and from the universal programming interface. The software contains the universal API module itself, the demo simulation of hardware, and the front-end programs to help developers write their own softwaremore » drivers along with example drivers for actual hardware controllers. The software allows user application programs to call devices simultaneously without race conditions (multitasking and concurrent access). The template suggested in this package permits developers to integrate various devices easily into their applications using the same API. The drivers can be stacked; i.e., they can call each other via the same interface.« less
NASA pyrotechnically actuated systems program
NASA Technical Reports Server (NTRS)
Schulze, Norman R.
1993-01-01
The Office of Safety and Mission Quality initiated a Pyrotechnically Actuated Systems (PAS) Program in FY-92 to address problems experienced with pyrotechnically actuated systems and devices used both on the ground and in flight. The PAS Program will provide the technical basis for NASA's projects to incorporate new technological developments in operational systems. The program will accomplish that objective by developing/testing current and new hardware designs for flight applications and by providing a pyrotechnic data base. This marks the first applied pyrotechnic technology program funded by NASA to address pyrotechnic issues. The PAS Program has been structured to address the results of a survey of pyrotechnic device and system problems with the goal of alleviating or minimizing their risks. Major program initiatives include the development of a Laser Initiated Ordnance System, a pyrotechnic systems data base, NASA Standard Initiator model, a NASA Standard Linear Separation System and a NASA Standard Gas Generator. The PAS Program sponsors annual aerospace pyrotechnic systems workshops.
Silicon Carbide Power Devices and Integrated Circuits
NASA Technical Reports Server (NTRS)
Lauenstein, Jean-Marie; Casey, Megan; Samsel, Isaak; LaBel, Ken; Chen, Yuan; Ikpe, Stanley; Wilcox, Ted; Phan, Anthony; Kim, Hak; Topper, Alyson
2017-01-01
An overview of the NASA NEPP Program Silicon Carbide Power Device subtask is given, including the current task roadmap, partnerships, and future plans. Included are the Agency-wide efforts to promote development of single-event effect hardened SiC power devices for space applications.
Evidence of soft bound behaviour in analogue memristive devices for neuromorphic computing.
Frascaroli, Jacopo; Brivio, Stefano; Covi, Erika; Spiga, Sabina
2018-05-08
The development of devices that can modulate their conductance under the application of electrical stimuli constitutes a fundamental step towards the realization of synaptic connectivity in neural networks. Optimization of synaptic functionality requires the understanding of the analogue conductance update under different programming conditions. Moreover, properties of physical devices such as bounded conductance values and state-dependent modulation should be considered as they affect storage capacity and performance of the network. This work provides a study of the conductance dynamics produced by identical pulses as a function of the programming parameters in an HfO 2 memristive device. The application of a phenomenological model that considers a soft approach to the conductance boundaries allows the identification of different operation regimes and to quantify conductance modulation in the analogue region. Device non-linear switching kinetics is recognized as the physical origin of the transition between different dynamics and motivates the crucial trade-off between degree of analog modulation and memory window. Different kinetics for the processes of conductance increase and decrease account for device programming asymmetry. The identification of programming trade-off together with an evaluation of device variations provide a guideline for the optimization of the analogue programming in view of hardware implementation of neural networks.
Component technology for space power systems
NASA Technical Reports Server (NTRS)
Finke, R.
1982-01-01
The Lewis/OAST program for the development of Component Technology for Space Power Systems is described. The program is divided into five generic areas: semiconductor devices (transistors, thyristors, and diodes); conductors (materials and transmission lines); dielectrics; magnetic devices; and thermal control devices. Examples of progress in each of the five areas is discussed. Bipolar power transistors up to 1000 V at 100 A with a gain of 10 and a 0.5 mu sec rise and fall time are presented. A new class of semiconductor devices with a possibility of switching 1000 000 V is described. Several 100 kW rotary power transformer designs and a 25 kW, 20 kHz transformer weighting 3.2 kg have been developed. Progress on the creation of diamond-like films for thermal devices and intercalated carbon fibers with the strength of steel and the conductivity of copper at one third the mass of copper is presented.
BioInnovate Ireland--fostering entrepreneurial activity through medical device innovation training.
Bruzzi, M S; Linehan, J H
2013-09-01
In the midst of a rich environment for medical device development and manufacturing, universities can play a critical role by developing relevant training programs to produce entrepreneurs who can be efficient and successful in creating early stage companies by understanding deeply the issues involved in creating a useful device, how to raise money, designing early clinical studies and locating manufacturing partners.
NASA Technical Reports Server (NTRS)
1991-01-01
Optoelectronic materials and devices are examined. Optoelectronic devices, which generate, detect, modulate, or switch electromagnetic radiation are being developed for a variety of space applications. The program includes spatial light modulators, solid state lasers, optoelectronic integrated circuits, nonlinear optical materials and devices, fiber optics, and optical networking photovoltaic technology and optical processing.
Development of a Device for Objective Assessment of Tinnitus in Humans
2015-10-01
AWARD NUMBER: W81XWH-14-2-0180 TITLE: Development of a Device for Objective Assessment of Tinnitus in Humans PRINCIPAL INVESTIGATOR: Jeremy G...5a. CONTRACT NUMBER Development of a Device for Objective Assessment of Tinnitus in Humans 5b. GRANT NUMBER W81XWH-14-2-0180 5c. PROGRAM ELEMENT...8 4 1. INTRODUCTION: Narrative that briefly (one paragraph) describes the subject, purpose and scope of the research. Tinnitus is the perception
Shuttle filter study. Volume 1: Characterization and optimization of filtration devices
NASA Technical Reports Server (NTRS)
1974-01-01
A program to develop a new technology base for filtration equipment and comprehensive fluid particulate contamination management techniques was conducted. The study has application to the systems used in the space shuttle and space station projects. The scope of the program is as follows: (1) characterization and optimization of filtration devices, (2) characterization of contaminant generation and contaminant sensitivity at the component level, and (3) development of a comprehensive particulate contamination management plane for space shuttle fluid systems.
ERIC Educational Resources Information Center
Broward County Schools, Fort Lauderdale, FL.
Part of a series on special educaton procedures in Florida, the manual presents information for teachers of visually impaired students regarding the use of electronic communication devices. Each of four types of devices is profiled: closed circuit television (CCTV), compressed speech devices, typewriter attachments for the Optacon (a device that…
Fusion energy division annual progress report, period ending December 31, 1980
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1981-11-01
The ORNL Program encompasses most aspects of magnetic fusion research including research on two magnetic confinement programs (tokamaks and ELMO bumpy tori); the development of the essential technologies for plasma heating, fueling, superconducting magnets, and materials; the development of diagnostics; the development of atomic physics and radiation effect data bases; the assessment of the environmental impact of magnetic fusion; the physics and engineering of present-generation devices; and the design of future devices. The integration of all of these activities into one program is a major factor in the success of each activity. An excellent example of this integration is themore » extremely successful application of neutral injection heating systems developed at ORNL to tokamaks both in the Fusion Energy Division and at Princeton Plasma Physics Laboratory (PPPL). The goal of the ORNL Fusion Program is to maintain this balance between plasma confinement, technology, and engineering activities.« less
Highly Efficient Multilayer Thermoelectric Devices
NASA Technical Reports Server (NTRS)
Boufelfel, Ali
2006-01-01
Multilayer thermoelectric devices now at the prototype stage of development exhibit a combination of desirable characteristics, including high figures of merit and high performance/cost ratios. These devices are capable of producing temperature differences of the order of 50 K in operation at or near room temperature. A solvent-free batch process for mass production of these state-of-the-art thermoelectric devices has also been developed. Like prior thermoelectric devices, the present ones have commercial potential mainly by virtue of their utility as means of controlled cooling (and/or, in some cases, heating) of sensors, integrated circuits, and temperature-critical components of scientific instruments. The advantages of thermoelectric devices for such uses include no need for circulating working fluids through or within the devices, generation of little if any noise, and high reliability. The disadvantages of prior thermoelectric devices include high power consumption and relatively low coefficients of performance. The present development program was undertaken in the hope of reducing the magnitudes of the aforementioned disadvantages and, especially, obtaining higher figures of merit for operation at and near room temperature. Accomplishments of the program thus far include development of an algorithm to estimate the heat extracted by, and the maximum temperature drop produced by, a thermoelectric device; solution of the problem of exchange of heat between a thermoelectric cooler and a water-cooled copper block; retrofitting of a vacuum chamber for depositing materials by sputtering; design of masks; and fabrication of multilayer thermoelectric devices of two different designs, denoted I and II. For both the I and II designs, the thicknesses of layers are of the order of nanometers. In devices of design I, nonconsecutive semiconductor layers are electrically connected in series. Devices of design II contain superlattices comprising alternating electron-acceptor (p)-doped and electron-donor (n)-doped, nanometer- thick semiconductor layers.
NASA Technical Reports Server (NTRS)
Blatt, M. H.; Bradshaw, R. D.; Risberg, J. A.
1980-01-01
Technology areas critical to the development of cryogenic capillary devices were studied. Passive cooling of capillary devices was investigated with an analytical and experimental study of wicking flow. Capillary device refilling with settled fluid was studied using an analytical and experimental program that resulted in successful correlation of a versatile computer program with test data. The program was used to predict Centaur D-1S LO2 and LH2 start basket refilling. Comparisons were made between the baseline Centaur D-1S propellant feed system and feed system alternatives including systems using capillary devices. The preferred concepts from the Centaur D-1S study were examined for APOTV and POTV vehicles for delivery and round trip transfer of payloads between LEO and GEO. Mission profiles were determined to provide propellant usage timelines and the payload partials were defined.
NASA Astrophysics Data System (ADS)
Larson, Michael
2012-03-01
This presentation will describe the history of the Nuclear Emergency Support Team (NEST) and its evolution over the years. NEST was formed due to a number of nuclear extortion threats received in the early 1970s. From the beginning NEST developed an extensive exercise program to test and expand capabilities. The Nuclear Assessment Program (NAP) was developed, in part, to determine if NEST deployments were required. A major revamp of the NEST program occurred in 1994. Many other organizations work in conjunction with NEST in particular the FBI and DOD. Considerable research and development has been performed in the areas of Access, Search, Diagnostics, Device Assessment, and Disablement. Extensive searches of material appearing in the unclassified literature have been and are being performed to see what is being said about nuclear materials and devices. A comprehensive study of Improvised Nuclear Devices (IND) is ongoing to determine what a terrorist can and cannot do. NEST now consists of four phases with the latest additions of Phase III, Disposition and Phase IV, Nuclear Forensics. LLNL-ABS-521775
ERIC Educational Resources Information Center
Lipson, Joseph I.; Fisher, Kathleen M.
1985-01-01
In the future, the requirements of industry will generate a wide range of hardware devices and software programs that will significantly alter and improve the quality of education. The driving forces behind the development of new technological devices include economics; emotional factors, e.g., the desire to develop aids for the handicapped;…
Strengthening the Role of Nurses in Medical Device Development.
Castner, Jessica; Sullivan, Suzanne S; Titus, Albert H; Klingman, Karen J
2016-01-01
Medical devices and innovative technology promise to revolutionize health care. Despite the importance of involving nurses in the collaborative medical device development processes, there are few learning opportunities in nursing programs. The purpose of this article is to provide a conceptual guide for nurse educators and researchers to engage nursing expertise in medical device development processes. A review of the literature guided the creation of the "Strengthening the Role of Nurses in Medical Device Development Roadmap" model. The model was used to describe how nurses can be engaged in multidisciplinary design of medical devices. An academic transdisciplinary team piloted the application of the model. The model includes the stages of needs assessment, planned brainstorm, feasibility determination, concept design, and prototype building. A transdisciplinary team case study of improving an asthma home-monitoring devices illustrates effective application of the model. Nurse leaders in the academic setting can effectively use the "Strengthening the Role of Nurses in Medical Device Development Roadmap" to inform their engagement of nurses in early medical device development and innovation processes. Copyright © 2016 Elsevier Inc. All rights reserved.
An embedded system developed for hand held assay used in water monitoring
NASA Astrophysics Data System (ADS)
Wu, Lin; Wang, Jianwei; Ramakrishna, Bharath; Hsueh, Mingkai; Liu, Jonathan; Wu, Qufei; Wu, Chao-Cheng; Cao, Mang; Chang, Chein-I.; Jensen, Janet L.; Jensen, James O.; Knapp, Harlan; Daniel, Robert; Yin, Ray
2005-11-01
The US Army Joint Service Agent Water Monitor (JSAWM) program is currently interested in an approach that can implement a hardware- designed device in ticket-based hand-held assay (currently being developed) used for chemical/biological agent detection. This paper presents a preliminary investigation of the proof of concept. Three components are envisioned to accomplish the task. One is the ticket development which has been undertaken by the ANP, Inc. Another component is the software development which has been carried out by the Remote Sensing Signal and Image Processing Laboratory (RSSIPL) at the University of Maryland, Baltimore County (UMBC). A third component is an embedded system development which can be used to drive the UMBC-developed software to analyze the ANP-developed HHA tickets on a small pocket-size device like a PDA. The main focus of this paper is to investigate the third component that is viable and is yet to be explored. In order to facilitate to prove the concept, a flatbed scanner is used to replace a ticket reader to serve as an input device. The Stargate processor board is used as the embedded System with Embedded Linux installed. It is connected to an input device such as scanner as well as output devices such as LCD display or laptop etc. It executes the C-Coded processing program developed for this embedded system and outputs its findings on a display device. The embedded system to be developed and investigated in this paper is the core of a future hardware device. Several issues arising in such an embedded system will be addressed. Finally, the proof-of-concept pilot embedded system will be demonstrated.
Development of a Device for Objective Assessment of Tinnitus in Humans
2016-10-01
AWARD NUMBER: W81XWH-14-2-0180 TITLE: Development of a Device for Objective Assessment of Tinnitus in Humans PRINCIPAL INVESTIGATOR: Jeremy G...SUBTITLE Development of a Device for Objective Assessment of Tinnitus in Humans 5a. CONTRACT NUMBER 5b. GRANT NUMBER W81XWH-14-2-0180 5c. PROGRAM...briefly (one paragraph) describes the subject, purpose and scope of the research. Tinnitus is the perception of sound in the ears or head when
US Navy superconductivity program
NASA Technical Reports Server (NTRS)
Gubser, Donald U.
1991-01-01
Both the new high temperature superconductors (HTS) and the low temperature superconductors (LTS) are important components of the Navy's total plan to integrate superconductivity into field operational systems. Fundamental research is an important component of the total Navy program and focuses on the HTS materials. Power applications (ship propulsion) use LTS materials while space applications (millimeter wave electronics) use HTS materials. The Space Experiment to be conducted at NRL will involve space flight testing of HTS devices built by industry and will demonstrate the ability to engineer and space qualify these devices for systems use. Another important component of the Navy's effort is the development of Superconducting Quantum Interference Device (SQUID) magnetometers. This program will use LTS materials initially, but plans to implement HTS materials as soon as possible. Hybrid HTS/LTS systems are probable in many applications. A review of the status of the Navy's HTS materials research is given as well as an update on the Navy's development efforts in superconductivity.
Research Spotlight: The next big thing is actually small.
Garcia, Carlos D
2012-07-01
Recent developments in materials, surface modifications, separation schemes, detection systems and associated instrumentation have allowed significant advances in the performance of lab-on-a-chip devices. These devices, also referred to as micro total analysis systems (µTAS), offer great versatility, high throughput, short analysis time, low cost and, more importantly, performance that is comparable to standard bench-top instrumentation. To date, µTAS have demonstrated advantages in a significant number of fields including biochemical, pharmaceutical, military and environmental. Perhaps most importantly, µTAS represent excellent platforms to introduce students to microfabrication and nanotechnology, bridging chemistry with other fields, such as engineering and biology, enabling the integration of various skills and curricular concepts. Considering the advantages of the technology and the potential impact to society, our research program aims to address the need for simpler, more affordable, faster and portable devices to measure biologically active compounds. Specifically, the program is focused on the development and characterization of a series of novel strategies towards the realization of integrated microanalytical devices. One key aspect of our research projects is that the developed analytical strategies must be compatible with each other; therefore, enabling their use in integrated devices. The program combines spectroscopy, surface chemistry, capillary electrophoresis, electrochemical detection and nanomaterials. This article discusses some of the most recent results obtained in two main areas of emphasis: capillary electrophoresis, microchip-capillary electrophoresis, electrochemical detection and interaction of proteins with nanomaterials.
A device-dependent interface for interactive image display
NASA Technical Reports Server (NTRS)
Perkins, D. C.; Szczur, M. R.; Owings, J.; Jamros, R. K.
1984-01-01
The structure of the device independent Display Management Subsystem (DMS) and the interface routines that are available to the applications programmer for use in developing a set of portable image display utility programs are described.
Developments in the photonics program at OSC
NASA Astrophysics Data System (ADS)
Peyghambarian, N.
2014-10-01
The photonics program at the College of Optical Sciences started nearly 30 years ago. In 1984, the program was focused on development of femtosecond laser sources and their use in investigating semiconductor carrier dynamics. The program grew into polymer and organic optics in late 1989 and was strengthened by the winning of the CAMP MURI from ONR in 1995 that was focused on multifunctional polymers including photorefractive polymers, organic light emitting diodes and 3D direct laser writing. Also in 1995, the areas of glass waveguide and fiber optic materials and devices were added to the program. In 2008, the optical communication and future internet research was started through winning the CIAN NSF ERC. Expertise in thin films, optical storage and the fundamental aspects of light are elements of the overall research program. Holographic 3D display, autofocus lenses, bio-medical imaging and devices for vision have also been ongoing research areas.
Mechanism Development, Testing, and Lessons Learned for the Advanced Resistive Exercise Device
NASA Technical Reports Server (NTRS)
Lamoreaux, Christopher D.; Landeck, Mark E.
2006-01-01
The Advanced Resistive Exercise Device (ARED) has been developed at NASA Johnson Space Center, for the International Space Station (ISS) program. ARED is a multi-exercise, high-load resistive exercise device, designed for long duration, human space missions. ARED will enable astronauts to effectively maintain their muscle strength and bone mass in the micro-gravity environment more effectively than any other existing devices. ARED's resistance is provided via two, 20.3 cm (8 in) diameter vacuum cylinders, which provide a nearly constant resistance source. ARED also has a means to simulate the inertia that is felt during a 1-G exercise routine via the flywheel subassembly, which is directly tied to the motion of the ARED cylinders. ARED is scheduled to fly on flight ULF 2 to the ISS and will be located in Node 1. Presently, ARED is in the middle of its qualification and acceptance test program. An extensive testing program and engineering evaluation has increased the reliability of ARED by bringing potential design issues to light before flight production. Some of those design issues, resolutions, and design details will be discussed in this paper.
Humanitarian Use Device and Humanitarian Device Exemption regulatory programs: pros and cons.
Bernad, Daniel Maxwell
2009-03-01
The US FDA established the Humanitarian Use Device (HUD) and Humanitarian Device Exemption (HDE) program to encourage medical device firms to address rare diseases. Despite being in existence for over a decade, there has only been one peer-reviewed publication examining this field. The objective of this report is to investigate how the HUD/HDE program differs from the standard regulatory system, discuss its potential advantages and disadvantages, and to speculate which humanitarian devices will be brought to market within the next 5 years. A total of 40 semistructured interviews with stakeholders, representing approximately half (n = 20, 49%) of the firms that have successfully obtained HDE-approved products, were performed in order to acquire the primary data for this paper. There appear to be short-term gains and long-term drains associated with launching humanitarian devices to market. This report aims to provide sponsors with information that may allow them to make better decisions during their product development of humanitarian devices and may, hopefully, also play a role in encouraging other sponsors to take the necessary steps forward in helping to find treatments for patients with rare diseases.
Scaling of Performance in Liquid Propellant Rocket Engine Combustion Devices
NASA Technical Reports Server (NTRS)
Hulka, James R.
2008-01-01
This paper discusses scaling of combustion and combustion performance in liquid propellant rocket engine combustion devices. In development of new combustors, comparisons are often made between predicted performance in a new combustor and measured performance in another combustor with different geometric and thermodynamic characteristics. Without careful interpretation of some key features, the comparison can be misinterpreted and erroneous information used in the design of the new device. This paper provides a review of this performance comparison, including a brief review of the initial liquid rocket scaling research conducted during the 1950s and 1960s, a review of the typical performance losses encountered and how they scale, a description of the typical scaling procedures used in development programs today, and finally a review of several historical development programs to see what insight they can bring to the questions at hand.
A Reliability Simulator for Radiation-Hard Microelectronics Development
1991-07-01
1 3.0 PHASE II WORK PLANS ................................................................ 2... plan . The correlation experimental details including the devices utilized, the hot-carrier stressing and the wafer-level radiation correlation procedure...channel devices, and a new lifetime extrapolation method is demonstrated for p-channel devices. 3.0 PHASE II WORK PLANS The Phase 1I program consisted of
Digital optical computers at the optoelectronic computing systems center
NASA Technical Reports Server (NTRS)
Jordan, Harry F.
1991-01-01
The Digital Optical Computing Program within the National Science Foundation Engineering Research Center for Opto-electronic Computing Systems has as its specific goal research on optical computing architectures suitable for use at the highest possible speeds. The program can be targeted toward exploiting the time domain because other programs in the Center are pursuing research on parallel optical systems, exploiting optical interconnection and optical devices and materials. Using a general purpose computing architecture as the focus, we are developing design techniques, tools and architecture for operation at the speed of light limit. Experimental work is being done with the somewhat low speed components currently available but with architectures which will scale up in speed as faster devices are developed. The design algorithms and tools developed for a general purpose, stored program computer are being applied to other systems such as optimally controlled optical communication networks.
Advanced interdisciplinary undergraduate program: light engineering
NASA Astrophysics Data System (ADS)
Bakholdin, Alexey; Bougrov, Vladislav; Voznesenskaya, Anna; Ezhova, Kseniia
2016-09-01
The undergraduate educational program "Light Engineering" of an advanced level of studies is focused on development of scientific learning outcomes and training of professionals, whose activities are in the interdisciplinary fields of Optical engineering and Technical physics. The program gives practical experience in transmission, reception, storage, processing and displaying information using opto-electronic devices, automation of optical systems design, computer image modeling, automated quality control and characterization of optical devices. The program is implemented in accordance with Educational standards of the ITMO University. The specific features of the Program is practice- and problem-based learning implemented by engaging students to perform research and projects, internships at the enterprises and in leading Russian and international research educational centers. The modular structure of the Program and a significant proportion of variable disciplines provide the concept of individual learning for each student. Learning outcomes of the program's graduates include theoretical knowledge and skills in natural science and core professional disciplines, deep knowledge of modern computer technologies, research expertise, design skills, optical and optoelectronic systems and devices.
Silicon-graphene photonic devices
NASA Astrophysics Data System (ADS)
Yin, Yanlong; Li, Jiang; Xu, Yang; Tsang, Hon Ki; Dai, Daoxin
2018-06-01
Silicon photonics has attracted much attention because of the advantages of CMOS (complementary-metal-oxide-semiconductor) compatibility, ultra-high integrated density, etc. Great progress has been achieved in the past decades. However, it is still not easy to realize active silicon photonic devices and circuits by utilizing the material system of pure silicon due to the limitation of the intrinsic properties of silicon. Graphene has been regarded as a promising material for optoelectronics due to its unique properties and thus provides a potential option for realizing active photonic integrated devices on silicon. In this paper, we present a review on recent progress of some silicon-graphene photonic devices for photodetection, all-optical modulation, as well as thermal-tuning. Project supported by the National Major Research and Development Program (No. 2016YFB0402502), the National Natural Science Foundation of China (Nos. 11374263, 61422510, 61431166001, 61474099, 61674127), and the National Key Research and Development Program (No. 2016YFA0200200).
Developing a smartphone interface for the Florida Environmental Public Health Tracking Web portal.
Jordan, Melissa; DuClos, Chris; Folsom, John; Thomas, Rebecca
2015-01-01
As smartphone and tablet devices continue to proliferate, it is becoming increasingly important to tailor information delivery to the mobile device. The Florida Environmental Public Health Tracking Program recognized that the mobile device user needs Web content formatted to smaller screen sizes, simplified data displays, and reduced textual information. The Florida Environmental Public Health Tracking Program developed a smartphone-friendly version of the state Web portal for easier access by mobile device users. The resulting smartphone-friendly portal combines calculated data measures such as inpatient hospitalizations and emergency department visits and presents them grouped by county, along with temporal trend graphs. An abbreviated version of the public health messaging provided on the traditional Web portal is also provided, along with social media connections. As a result of these efforts, the percentage of Web site visitors using an iPhone tripled in just 1 year.
Coutinho, Lincoln Figueira Marins; Nazario, Carlos Eduardo Domingues; Monteiro, Alessandra Maffei; Lanças, Fernando Mauro
2014-08-01
Analyses in chromatographic systems able to save mobile and stationary phases without reducing efficiency and resolution are of current interest. These advantages regarding savings have challenged us to develop a system dedicated to miniaturized liquid chromatography. This paper reports on the development of a high-pressure syringe-type pump, an oven able to perform isothermal and temperature programming and a software program to control these chromatographic devices. The experimental results show that the miniaturized system can generate reproducible and accurate temperature and flow rate. The system was applied to the separation of statins and tetracylines and showed excellent performance. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
A training paradigm to enhance performance and safe use of an innovative neuroendovascular device
Ricci, Donald R.; Marotta, Thomas R.; Riina, Howard A.; Wan, Martina; De Vries, Joost
2016-01-01
Training has been important to facilitate the safe use of new devices designed to repair vascular structures. This paper outlines the generic elements of a training program for vascular devices and uses as an example the actual training requirements for a novel device developed for the treatment of bifurcation intracranial aneurysms. Critical elements of the program include awareness of the clinical problem, technical features of device, case selection, and use of a simulator. Formal proctoring, evaluation of the training, and recording the clinical outcomes complement these elements. Interventional physicians should embrace the merits of a training module to improve the user experience, and vendors, physicians, and patients alike should be aligned in the goal of device training to improve its success rate and minimize complications of the procedure. PMID:27867466
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-15
...] International Medical Device Regulators Forum; Medical Device Single Audit Program International Coalition Pilot... Drug Administration (FDA) is announcing participation in the Medical Device Single Audit Program International Coalition Pilot Program. The Medical Device Single Audit Program (MDSAP) was designed and...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, Juhee; Lee, Sungpyo; Lee, Moo Hyung
Quasi-unipolar non-volatile organic transistor memory (NOTM) can combine the best characteristics of conventional unipolar and ambipolar NOTMs and, as a result, exhibit improved device performance. Unipolar NOTMs typically exhibit a large signal ratio between the programmed and erased current signals but also require a large voltage to program and erase the memory cells. Meanwhile, an ambipolar NOTM can be programmed and erased at lower voltages, but the resulting signal ratio is small. By embedding a discontinuous n-type fullerene layer within a p-type pentacene film, quasi-unipolar NOTMs are fabricated, of which the signal storage utilizes both electrons and holes while themore » electrical signal relies on only hole conduction. These devices exhibit superior memory performance relative to both pristine unipolar pentacene devices and ambipolar fullerene/pentacene bilayer devices. The quasi-unipolar NOTM exhibited a larger signal ratio between the programmed and erased states while also reducing the voltage required to program and erase a memory cell. This simple approach should be readily applicable for various combinations of advanced organic semiconductors that have been recently developed and thereby should make a significant impact on organic memory research.« less
75 FR 10225 - Proposed Information Collection; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-05
... a telecommunications device for the deaf (TTY-TDD) may call (202) 565-2799 between 8:30 a.m. and 5 p... AmeriCorps Application Instructions: Administrative, Program Development and Training grants. State... and National Administrative, Program Development and Training, and Disability grants. Current Action...
Laboratory development and testing of spacecraft diagnostics
NASA Astrophysics Data System (ADS)
Amatucci, William; Tejero, Erik; Blackwell, Dave; Walker, Dave; Gatling, George; Enloe, Lon; Gillman, Eric
2017-10-01
The Naval Research Laboratory's Space Chamber experiment is a large-scale laboratory device dedicated to the creation of large-volume plasmas with parameters scaled to realistic space plasmas. Such devices make valuable contributions to the investigation of space plasma phenomena under controlled, reproducible conditions, allowing for the validation of theoretical models being applied to space data. However, in addition to investigations such as plasma wave and instability studies, such devices can also make valuable contributions to the development and testing of space plasma diagnostics. One example is the plasma impedance probe developed at NRL. Originally developed as a laboratory diagnostic, the sensor has now been flown on a sounding rocket, is included on a CubeSat experiment, and will be included on the DoD Space Test Program's STP-H6 experiment on the International Space Station. In this talk, we will describe how the laboratory simulation of space plasmas made this development path possible. Work sponsored by the US Naval Research Laboratory Base Program.
EXOS research on master controllers for robotic devices
NASA Technical Reports Server (NTRS)
Marcus, Beth A.; An, Ben; Eberman, Brian
1992-01-01
Two projects are currently being conducted by EXOS under the Small Business Innovation Research (SBIR) program with NASA. One project will develop a force feedback device for controlling robot hands, the other will develop an elbow and shoulder exoskeleton which can be integrated with other EXOS devices to provide whole robot arm and hand control. Aspects covered are the project objectives, important research issues which have arisen during the developments, and interim results of the projects. The Phase 1 projects currently underway will result in hardware prototypes and identification of research issues required for complete system development and/or integration.
Evaluation of the New Mexico ignition interlock program.
DOT National Transportation Integrated Search
2010-11-01
This Evaluation of the New Mexico Ignition Interlock Program begins by summarizing the development of : alcohol ignition interlock devices, laws, and programs during the past 22 years. It then reviews the laws that : were written in New Mexico from 1...
Contributive research in compound semiconductor material and related devices
NASA Astrophysics Data System (ADS)
Twist, James R.
1988-05-01
The objective of this program was to provide the Electronic Device Branch (AFWAL/AADR) with the support needed to perform state of the art electronic device research. In the process of managing and performing on the project, UES has provided a wide variety of scientific and engineering talent who worked in-house for the Avionics Laboratory. These personnel worked on many different types of research programs from gas phase microwave driven lasers, CVD and MOCVD of electronic materials to Electronic Device Technology for new devices. The fields of research included MBE and theoretical research in this novel growth technique. Much of the work was slanted towards the rapidly developing technology of GaAs and the general thrust of the research that these tasks started has remained constant. This work was started because the Avionics Laboratory saw a chance to advance the knowledge and level of the current device technology by working in the compounds semiconductor field. UES is pleased to have had the opportunity to perform on this program and is looking forward to future efforts with the Avionics Laboratory.
ERIC Educational Resources Information Center
Grant, Kelly J.
2016-01-01
The purpose of this study was to evaluate the impact of the first year of a multi-year, district-wide professional development program for teachers that accompanied a one-to-one Apple device rollout for all students. A mixed-method research design was used to perform a logic model of program evaluation. Teacher self-reported proficiency in basic…
Development of an accommodative smartphone app for medical guidelines in pediatric emergencies.
Schmucker, Michael; Heid, Jörn; Haag, Martin
2014-01-01
One of the outcomes of a training concept for physicians and nurses concerning pediatric emergencies at the Heidelberg University Hospital was that the work and procedures in childhood emergencies could be simplified by replacing the existing paper-based guidelines with a smartphone app. Since the project funds for this were already used up, a group of students from the master program "Medical Informatics" of Heidelberg and Heilbronn Universities took over the development of the app. Particular attention was given to the need for compatibility with the variety of devices (device size and screen resolution) and platform independence. The guidelines themselves were scripted in HTML5, JavaScript and CSS (responsive web design); managed by a container programmed in Sencha Touch. Even though the app is not yet available in the App-Store due to the limited timeframe, the students gained a great deal of valuable experience in developing platform independent software for mobile devices.
LABORATORY PROCESS CONTROLLER USING NATURAL LANGUAGE COMMANDS FROM A PERSONAL COMPUTER
NASA Technical Reports Server (NTRS)
Will, H.
1994-01-01
The complex environment of the typical research laboratory requires flexible process control. This program provides natural language process control from an IBM PC or compatible machine. Sometimes process control schedules require changes frequently, even several times per day. These changes may include adding, deleting, and rearranging steps in a process. This program sets up a process control system that can either run without an operator, or be run by workers with limited programming skills. The software system includes three programs. Two of the programs, written in FORTRAN77, record data and control research processes. The third program, written in Pascal, generates the FORTRAN subroutines used by the other two programs to identify the user commands with the user-written device drivers. The software system also includes an input data set which allows the user to define the user commands which are to be executed by the computer. To set the system up the operator writes device driver routines for all of the controlled devices. Once set up, this system requires only an input file containing natural language command lines which tell the system what to do and when to do it. The operator can make up custom commands for operating and taking data from external research equipment at any time of the day or night without the operator in attendance. This process control system requires a personal computer operating under MS-DOS with suitable hardware interfaces to all controlled devices. The program requires a FORTRAN77 compiler and user-written device drivers. This program was developed in 1989 and has a memory requirement of about 62 Kbytes.
The Next Big Thing is Actually Small
Garcia, Carlos D.
2013-01-01
Summary Recent developments in materials, surface modifications, separation schemes, detection systems, and associated instrumentation have allowed significant advances in the performance of lab-on-a-chip devices. These devices, also referred to as micro total analysis systems (µTAS), offer great versatility, high throughput, short analysis time, low cost, and more importantly, performance that is comparable to standard bench-top instrumentation. To date, µTAS have demonstrated advantages in a significant number of fields including biochemical, pharmaceutical, military, and environmental. Perhaps most importantly, µTAS represent excellent platforms to introduce students to microfabrication and nanotechnology, bridging chemistry with other fields such as engineering and biology, enabling the integration of various skills and curricular concepts. Considering the advantages of the technology and the potential impact to society, our research program aims to address the need for simpler, more affordable, faster, and portable devices to measure biologically-active compounds. Specifically, the program is focused on the development and characterization of a series of novel strategies towards the realization of integrated microanalytical devices. One key aspect of our research projects is that the developed analytical strategies must be compatible with each other, therefore enabling their use in integrated devices. The program combines spectroscopy, surface chemistry, capillary electrophoresis, electrochemical detection, and nanomaterials. This article discusses some of the most recent results obtained in two main areas of emphasis: ▪Capillary Electrophoresis, Microchip-CE, Electrochemical Detection, and▪Interaction of Proteins with Nanomaterials PMID:22877217
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mundy, D; Tryggestad, E; Beltran, C
Purpose: To develop daily and monthly quality assurance (QA) programs in support of a new spot-scanning proton treatment facility using a combination of commercial and custom equipment and software. Emphasis was placed on efficiency and evaluation of key quality parameters. Methods: The daily QA program was developed to test output, spot size and position, proton beam energy, and image guidance using the Sun Nuclear Corporation rf-DQA™3 device and Atlas QA software. The program utilizes standard Atlas linear accelerator tests repurposed for proton measurements and a custom jig for indexing the device to the treatment couch. The monthly QA program wasmore » designed to test mechanical performance, image quality, radiation quality, isocenter coincidence, and safety features. Many of these tests are similar to linear accelerator QA counterparts, but many require customized test design and equipment. Coincidence of imaging, laser marker, mechanical, and radiation isocenters, for instance, is verified using a custom film-based device devised and manufactured at our facility. Proton spot size and position as a function of energy are verified using a custom spot pattern incident on film and analysis software developed in-house. More details concerning the equipment and software developed for monthly QA are included in the supporting document. Thresholds for daily and monthly tests were established via perturbation analysis, early experience, and/or proton system specifications and associated acceptance test results. Results: The periodic QA program described here has been in effect for approximately 9 months and has proven efficient and sensitive to sub-clinical variations in treatment delivery characteristics. Conclusion: Tools and professional guidelines for periodic proton system QA are not as well developed as their photon and electron counterparts. The program described here efficiently evaluates key quality parameters and, while specific to the needs of our facility, could be readily adapted to other proton centers.« less
Development of a simulated smart pump interface.
Elias, Beth L; Moss, Jacqueline A; Shih, Alan; Dillavou, Marcus
2014-01-01
Medical device user interfaces are increasingly complex, resulting in a need for evaluation in clinicallyaccurate settings. Simulation of these interfaces can allow for evaluation, training, and use for research without the risk of harming patients and with a significant cost reduction over using the actual medical devices. This pilot project was phase 1 of a study to define and evaluate a methodology for development of simulated medical device interface technology to be used for education, device development, and research. Digital video and audio recordings of interface interactions were analyzed to develop a model of a smart intravenous medication infusion pump user interface. This model was used to program a high-fidelity simulated smart intravenous medication infusion pump user interface on an inexpensive netbook platform.
Development of qualification guidelines for personal computer-based aviation training devices.
DOT National Transportation Integrated Search
1995-02-01
Recent advances in the capabilities of personal computers have resulted in an increase in the number of flight simulation programs made available as Personal Computer-Based Aviation Training Devices (PCATDs).The potential benefits of PCATDs have been...
Rice, Laura A; Isaacs, Zadok; Ousley, Cherita; Sosnoff, Jacob
2018-01-01
Falls are a common concern for wheeled mobility device users with multiple sclerosis (MS); however, no evidence-based fall prevention programs have been developed to meet the specific needs of the population. We examine the preliminary feasibility of a fall management intervention in wheeled mobility device users with MS. Study participants were exposed to an intervention program targeting risk factors for falls, including transfer skills and seated postural control. The feasibility of the program was evaluated by assessing participant perspectives, cost, recruitment rates, study adherence, participant retention, safety, and the ability to collect primary and secondary outcomes, including fall frequency, concerns about falling, transfer quality, and seated postural control. 16 wheeled mobility device users completed the program, which was found to be feasible and was positively evaluated by participants. No adverse events were experienced. After exposure to the intervention, fall frequency significantly decreased (P < .001) and transfer quality (P = .001) and seated postural control (P = .002) significantly improved. No significant differences were found regarding concerns about falling (P = .728). This study examined the feasibility of an intervention program to manage fall risk in wheeled mobility device users with MS. The program was found to be feasible, and preliminary results showed the intervention to be effective in decreasing fall frequency. Additional testing is needed to further examine the efficacy and long-term impact of the intervention.
Payload IVA training and simulation
NASA Technical Reports Server (NTRS)
Monsees, J. H.
1982-01-01
The development of a training program for the intravehicular operation of space shuttle payloads is discussed. The priorities for the program are compliance with established training standards, and accommodating changes. Simulation devices are also reviewed.
A statistical data analysis and plotting program for cloud microphysics experiments
NASA Technical Reports Server (NTRS)
Jordan, A. J.
1981-01-01
The analysis software developed for atmospheric cloud microphysics experiments conducted in the laboratory as well as aboard a KC-135 aircraft is described. A group of four programs was developed and implemented on a Hewlett Packard 1000 series F minicomputer running under HP's RTE-IVB operating system. The programs control and read data from a MEMODYNE Model 3765-8BV cassette recorder, format the data on the Hewlett Packard disk subsystem, and generate statistical data (mean, variance, standard deviation) and voltage and engineering unit plots on a user selected plotting device. The programs are written in HP FORTRAN IV and HP ASSEMBLY Language with the graphics software using the HP 1000 Graphics. The supported plotting devices are the HP 2647A graphics terminal, the HP 9872B four color pen plotter, and the HP 2608A matrix line printer.
System-Level Integrated Circuit (SLIC) development for phased array antenna applications
NASA Technical Reports Server (NTRS)
Shalkhauser, K. A.; Raquet, C. A.
1991-01-01
A microwave/millimeter wave system-level integrated circuit (SLIC) being developed for use in phased array antenna applications is described. The program goal is to design, fabricate, test, and deliver an advanced integrated circuit that merges radio frequency (RF) monolithic microwave integrated circuit (MMIC) technologies with digital, photonic, and analog circuitry that provide control, support, and interface functions. As a whole, the SLIC will offer improvements in RF device performance, uniformity, and stability while enabling accurate, rapid, repeatable control of the RF signal. Furthermore, the SLIC program addresses issues relating to insertion of solid state devices into antenna systems, such as the reduction in number of bias, control, and signal lines. Program goals, approach, and status are discussed.
System-level integrated circuit (SLIC) development for phased array antenna applications
NASA Technical Reports Server (NTRS)
Shalkhauser, K. A.; Raquet, C. A.
1991-01-01
A microwave/millimeter wave system-level integrated circuit (SLIC) being developed for use in phased array antenna applications is described. The program goal is to design, fabricate, test, and deliver an advanced integrated circuit that merges radio frequency (RF) monolithic microwave integrated circuit (MMIC) technologies with digital, photonic, and analog circuitry that provide control, support, and interface functions. As a whole, the SLIC will offer improvements in RF device performance, uniformity, and stability while enabling accurate, rapid, repeatable control of the RF signal. Furthermore, the SLIC program addresses issues relating to insertion of solid state devices into antenna systems, such as the reduction in number of bias, control, and signal lines. Program goals, approach, and status are discussed.
A uniform approach for programming distributed heterogeneous computing systems
Grasso, Ivan; Pellegrini, Simone; Cosenza, Biagio; Fahringer, Thomas
2014-01-01
Large-scale compute clusters of heterogeneous nodes equipped with multi-core CPUs and GPUs are getting increasingly popular in the scientific community. However, such systems require a combination of different programming paradigms making application development very challenging. In this article we introduce libWater, a library-based extension of the OpenCL programming model that simplifies the development of heterogeneous distributed applications. libWater consists of a simple interface, which is a transparent abstraction of the underlying distributed architecture, offering advanced features such as inter-context and inter-node device synchronization. It provides a runtime system which tracks dependency information enforced by event synchronization to dynamically build a DAG of commands, on which we automatically apply two optimizations: collective communication pattern detection and device-host-device copy removal. We assess libWater’s performance in three compute clusters available from the Vienna Scientific Cluster, the Barcelona Supercomputing Center and the University of Innsbruck, demonstrating improved performance and scaling with different test applications and configurations. PMID:25844015
A uniform approach for programming distributed heterogeneous computing systems.
Grasso, Ivan; Pellegrini, Simone; Cosenza, Biagio; Fahringer, Thomas
2014-12-01
Large-scale compute clusters of heterogeneous nodes equipped with multi-core CPUs and GPUs are getting increasingly popular in the scientific community. However, such systems require a combination of different programming paradigms making application development very challenging. In this article we introduce libWater, a library-based extension of the OpenCL programming model that simplifies the development of heterogeneous distributed applications. libWater consists of a simple interface, which is a transparent abstraction of the underlying distributed architecture, offering advanced features such as inter-context and inter-node device synchronization. It provides a runtime system which tracks dependency information enforced by event synchronization to dynamically build a DAG of commands, on which we automatically apply two optimizations: collective communication pattern detection and device-host-device copy removal. We assess libWater's performance in three compute clusters available from the Vienna Scientific Cluster, the Barcelona Supercomputing Center and the University of Innsbruck, demonstrating improved performance and scaling with different test applications and configurations.
Research Needs: Prime-Power for High Energy Space Systems.
1982-06-01
nuclear sources included both developments from earlier NASA/AEC efforts, such as the present SP-100 program , and also advanced concepts in the form of...and, in some cases, set aside). major programs of applied-research and exploratory- development exist at AFWAL and at NASA labora- tories. The results...decades. In such a research program , the particular I problems of a specific device presently under development are less important than the creation of
Simulation of Robot Kinematics Using Interactive Computer Graphics.
ERIC Educational Resources Information Center
Leu, M. C.; Mahajan, R.
1984-01-01
Development of a robot simulation program based on geometric transformation softwares available in most computer graphics systems and program features are described. The program can be extended to simulate robots coordinating with external devices (such as tools, fixtures, conveyors) using geometric transformations to describe the…
Improvement of screening methods for silicon planar semiconductor devices
NASA Technical Reports Server (NTRS)
Berger, W. M.
1972-01-01
The results of the program for the development of a more sensitive method for selecting silicon planar semiconductor devices for long life applications are reported. The manufacturing technologies (MOS and Bipolar) are discussed along with the screening procedures developed as a result of the tests and evaluations, and the effectiveness of the MOS and Bilayer screening procedures are evaluated.
Fusion Energy Division progress report, 1 January 1990--31 December 1991
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sheffield, J.; Baker, C.C.; Saltmarsh, M.J.
1994-03-01
The Fusion Program of the Oak Ridge National Laboratory (ORNL), a major part of the national fusion program, encompasses nearly all areas of magnetic fusion research. The program is directed toward the development of fusion as an economical and environmentally attractive energy source for the future. The program involves staff from ORNL, Martin Marietta Energy systems, Inc., private industry, the academic community, and other fusion laboratories, in the US and abroad. Achievements resulting from this collaboration are documented in this report, which is issued as the progress report of the ORNL Fusion Energy Division; it also contains information from componentsmore » for the Fusion Program that are external to the division (about 15% of the program effort). The areas addressed by the Fusion Program include the following: experimental and theoretical research on magnetic confinement concepts; engineering and physics of existing and planned devices, including remote handling; development and testing of diagnostic tools and techniques in support of experiments; assembly and distribution to the fusion community of databases on atomic physics and radiation effects; development and testing of technologies for heating and fueling fusion plasmas; development and testing of superconducting magnets for containing fusion plasmas; development and testing of materials for fusion devices; and exploration of opportunities to apply the unique skills, technology, and techniques developed in the course of this work to other areas (about 15% of the Division`s activities). Highlights from program activities during 1990 and 1991 are presented.« less
Minimum Requirement Program: A Potential Device for Promoting Equality.
ERIC Educational Resources Information Center
Lewy, Arieh
1985-01-01
The Minimum Requirement Program (MRP) was introduced in Israel in the 1960s but was discontinued. The Parenthesis Program, a 1962 revision of the original program, restricted objectives in the syllabus which were deemed too difficult. Achievement gaps between population subgroups existed in the 1980s when a new MRP was developed. (GDC)
Advanced release technologies program
NASA Technical Reports Server (NTRS)
Purdy, Bill
1994-01-01
The objective of the ARTS program was to develop lighter and less expensive spacecraft ordnance and release systems that answer to the requirements of a wide variety of spacecraft applications. These improvements were to be evaluated at the spacecraft system level, as it was determined that there were substantial system-level costs associated with the present ordnance and release subsystems. New, better devices were to be developed, then flight qualified, then integrated into a flight experiment in order to prove the reliability required for their subsequent use on high-reliability spacecraft. The secondary goal of the program was to quantify the system-level benefits of these new subsystems based upon the development program results. Three non-explosive release mechanisms and one laser-diode-based ordnance system were qualified under the program. The release devices being developed were required to release high preloads because it is easier to scale down a release mechanism than to scale it up. The laser initiator developed was required to be a direct replacement for NASA Standard Initiators, since these are the most common initiator in use presently. The program began in October, 1991, with completion of the flight experiment scheduled for February, 1994. This paper provides an overview of the ARTS program, discusses the benefits of using the ARTS components, introduces the new components, compares them with conventional systems and each other, and provides recommendations on how best to implement them.
An Innovative Instrument Flight Training Program.
ERIC Educational Resources Information Center
Caro, Paul W.
An innovative flight training program, its development, and initial administration are described. The program involves use of a commercially available training device in a twin-engine transition and instrument training course. Principal features of the training include redefinition of the flight instructor's role, and incentive award system,…
Apollo experience report: Electrical wiring subsystem
NASA Technical Reports Server (NTRS)
White, L. D.
1975-01-01
The general requirements of the electrical wiring subsystems and the problem areas and solutions that occurred during the major part of the Apollo Program are detailed in this report. The concepts and definitions of specific requirements for electrical wiring; wire-connecting devices; and wire-harness fabrication, checkout, and installation techniques are discussed. The design and development of electrical wiring and wire-connecting devices are described. Mission performance is discussed, and conclusions and recommendations for future programs are presented.
Project for millimeter and submillimeter-wave devices, and the experimental equipments
NASA Astrophysics Data System (ADS)
Hirose, Nobumitu; Kiyokawa, Masahiro; Matsui, Toshiaki
1995-09-01
A research and development program on millimeter and submillimeter wave devices is described. The facilities provided for this program are also described. In 1994, construction of the clean room was completed. Since then several machines and tools have been installed. We describe some results which have been obtained using these machines and tools. For example, a resist pattern with a 40 nm width on a 400 nm thick polymethylmethacrylate (PMMA) film was obtained.
Residential Water Conservation in a Noncrisis Setting: Results of a New Jersey Experiment
NASA Astrophysics Data System (ADS)
Palmini, Dennis J.; Shelton, Theodore B.
1982-08-01
East Brunswick Township, New Jersey, conducted a water conservation program in 1980 by distributing to 564 households free packets of water-saving devices purchased with municipal funds. The program was not a response to a current water supply crisis, and appeals for cooperation were based on the private economic benefits of water conservation. Statistical procedures were developed to measure the proportions of households installing each of the devices distributed, water savings and program costs. Two-thirds of the households receiving the packets installed at least one device. Average annual water savings per home receiving a packet were estimated at 5010 gallons (18.96 kl). Amortized over ten years at a 10% discount rate, the program cost was approximately 35 cents per 1000 gallons of water saved (9.2 cents per kl). The East Brunswick results compare well to the results obtained from similar conservation programs in a pair of California communities during the 1976-1977 drought.
Edwards, Eric S; Edwards, Evan T; Simons, F Estelle R; North, Robert
2015-05-01
The systematic application of human factors engineering (HFE) principles to the development of drug-device combination products, including epinephrine auto-injectors (EAIs), has the potential to improve the effectiveness and safety of drug administration. A PubMed search was performed to assess the role of HFE in the development of drug-device combination products. The following keywords were used in different combinations: 'human factors engineering,' 'human factors,' 'medical products,' 'epinephrine/adrenaline auto-injector,' 'healthcare' and 'patient safety.' This review provides a summary of HFE principles and their application to the development of drug-device combination products as advised by the US FDA. It also describes the HFE process that was applied to the development of Auvi-Q, a novel EAI, highlighting specific steps that occurred during the product-development program. For drug-device combination products, device labeling and usability are critical and have the potential to impact clinical outcomes. Application of HFE principles to the development of drug-delivery devices has the potential to improve product quality and reliability, reduce risk and improve patient safety when applied early in the development process. Additional clinical and real-world studies will confirm whether the application of HFE has helped to develop an EAI that better meets the needs of patients at risk of anaphylaxis.
A description of the new 3D electron gun and collector modeling tool: MICHELLE
DOE Office of Scientific and Technical Information (OSTI.GOV)
Petillo, J.; Mondelli, A.; Krueger, W.
1999-07-01
A new 3D finite element gun and collector modeling code is under development at SAIC in collaboration with industrial partners and national laboratories. This development program has been designed specifically to address the shortcomings of current simulation and modeling tools. In particular, although there are 3D gun codes that exist today, their ability to address fine scale features is somewhat limited in 3D due to disparate length scales of certain classes of devices. Additionally, features like advanced emission rules, including thermionic Child's law and comprehensive secondary emission models also need attention. The program specifically targets problems classes including gridded-guns, sheet-beammore » guns, multi-beam devices, and anisotropic collectors. The presentation will provide an overview of the program objectives, the approach to be taken by the development team, and a status of the project.« less
Scaling of Performance in Liquid Propellant Rocket Engine Combustors
NASA Technical Reports Server (NTRS)
Hulka, James
2008-01-01
The objectives are: a) Re-introduce to you the concept of scaling; b) Describe the scaling research conducted in the 1950s and early 1960s, and present some of their conclusions; c) Narrow the focus to scaling for performance of combustion devices for liquid propellant rocket engines; and d) Present some results of subscale to full-scale performance from historical programs. Scaling is "The ability to develop new combustion devices with predictable performance on the basis of test experience with old devices." Scaling can be used to develop combustion devices of any thrust size from any thrust size. Scaling is applied mostly to increase thrust. Objective is to use scaling as a development tool. - Move injector design from an "art" to a "science"
Radiation Effects in III-V Nanowire Devices
2016-09-01
Nanowire Devices Distribution Statement A. Approved for public release; distribution is unlimited. September 2016 HDTRA1-11-1-0021 Steven R...Name: Prof. S. R. J. Brueck Organization/Institution: University of New Mexico Project Title: Radiation Effects in III-V Nanowire Devices What are...the agency approved application or plan. The objectives of this program were to: a) develop a new nanowire transistor technology based on nanoscale
The SAGES Fundamental Use of Surgical Energy program (FUSE): history, development, and purpose.
Fuchshuber, P; Schwaitzberg, S; Jones, D; Jones, S B; Feldman, L; Munro, M; Robinson, T; Purcell-Jackson, G; Mikami, D; Madani, A; Brunt, M; Dunkin, B; Gugliemi, C; Groah, L; Lim, R; Mischna, J; Voyles, C R
2018-06-01
Adverse events due to energy device use in surgical operating rooms are a daily occurrence. These occur at a rate of approximately 1-2 per 1000 operations. Hundreds of operating room fires occur each year in the United States, some causing severe injury and even mortality. The Society of American Gastrointestinal and Endoscopic Surgeons (SAGES) therefore created the first comprehensive educational curriculum on the safe use of surgical energy devices, called Fundamental Use of Surgical Energy (FUSE). This paper describes the history, development, and purpose of this important training program for all members of the operating room team. The databases of SAGES and the FUSE committee as well as personal photographs and documents of members of the FUSE task force were used to establish a brief history of the FUSE program from its inception to its current status. The authors were able to detail all aspects of the history, development, and national as well as global implementation of the third SAGES Fundamentals Program FUSE. The written documentation of the making of FUSE is an important contribution to the history and mission of SAGES and allows the reader to understand the idea, concept, realization, and implementation of the only free online educational tool for physicians on energy devices available today. FUSE is the culmination of the SAGES efforts to recognize gaps in patient safety and develop state-of-the-art educational programs to address those gaps. It is the goal of the FUSE task force to ensure that general FUSE implementation becomes multinational, involving as many countries as possible.
ARO Research Instrumentation Program - IR Spectrometer Procurement
2015-11-01
supercapacitors ). The Nicolet iS50R spectrometer has been synchronized with a potentiostat to 1. REPORT DATE (DD-MM-YYYY) 4. TITLE AND SUBTITLE...interfaces. This information is important for the development of enhanced energy conversion processes and devices (e.g., supercapacitors ). The Nicolet iS50R...electrode interfaces. This information is important for the development of enhanced energy conversion processes and devices (e.g., supercapacitors
Development of a helmet-mounted PLZT thermal/flash protection system. [Protective goggles
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harris, J.O. Jr.; Cutchen, J.T.; Pfoff, B.J.
1976-01-01
Sandia Laboratories is developing PLZT thermal/flash protective devices (TFPD's) goggles to prevent exposure and resultant eye damage from nuclear weapon detonations. The primary emphasis of the present program is to transfer technology and establish production capability for helmet-mounted PLZT/TFPD goggles for USAF flight crews, with a non-helmet-mounted configuration to follow. The first production units are anticipated in the fall of 1977. The operating principles of the PLZT/TFPD goggle device are briefly outlined, and the device configuration and operational characteristics are described.
Mod-1 Wind Turbine at Boone, North Carolina
1979-06-21
A Mod-1 2000-kilowatt wind turbine designed by National Aeronautics and Space Administration (NASA) Lewis Research Center and constructed in Boone, North Carolina. The wind turbine program was a joint program between NASA and the Energy Research and Development Administration (ERDA) during the 1970s to develop less expensive forms of energy. NASA Lewis was assigned the responsibility of developing large horizontal-axis wind turbines. The program included a series of increasingly powerful wind turbines, designated: Mod-0A, Mod-1, WTS-4, and Mod-5. The program’s first device was a Mod-0 100-kilowatt wind turbine test bed at NASA’s Plum Brook Station. There were four Mod-0A 200-kilowatt turbines built in New Mexico, Hawaii, Puerto Rico, and Rhode Island. The 2000-kilowatt wind turbine in North Carolina, seen here, was the only Mod-1 machine constructed. The two-bladed, 200-foot diameter device was built in May 1979 and began operation that September. The Mod-1 turbine performed exceedingly well and was fully integrated into the local power grid. NASA researchers also used the North Carolina device to study its effect on noise and television transmission.
NASA Astrophysics Data System (ADS)
Hughes, Allen A.
1994-12-01
Public safety can be enhanced through the development of a comprehensive medical device risk management. This can be accomplished through case studies using a framework that incorporates cost-benefit analysis in the evaluation of risk management attributes. This paper presents a framework for evaluating the risk management system for regulatory Class III medical devices. The framework consists of the following sixteen attributes of a comprehensive medical device risk management system: fault/failure analysis, premarket testing/clinical trials, post-approval studies, manufacturer sponsored hospital studies, product labeling, establishment inspections, problem reporting program, mandatory hospital reporting, medical literature surveillance, device/patient registries, device performance monitoring, returned product analysis, autopsy program, emergency treatment funds/interim compensation, product liability, and alternative compensation mechanisms. Review of performance histories for several medical devices can reveal the value of information for many attributes, and also the inter-dependencies of the attributes in generating risk information flow. Such an information flow network is presented as a starting point for enhancing medical device risk management by focusing on attributes with high net benefit values and potential to spur information dissemination.
High-speed sorting of grains by color and surface texture
USDA-ARS?s Scientific Manuscript database
A high-speed, low-cost, image-based sorting device was developed to detect and separate grains with different colors/textures. The device directly combines a complementary metal–oxide–semiconductor (CMOS) color image sensor with a field-programmable gate array (FPGA) that was programmed to execute ...
Laboratory Directed Research and Development Program FY98
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hansen, T.; Chartock, M.
1999-02-05
The Ernest Orlando Lawrence Berkeley National Laboratory (LBNL or Berkeley Lab) Laboratory Directed Research and Development Program FY 1998 report is compiled from annual reports submitted by principal investigators following the close of the fiscal year. This report describes the supported projects and summarizes their accomplishments. It constitutes a part of the Laboratory Directed Research and Development (LDRD) program planning and documentation process that includes an annual planning cycle, projection selection, implementation, and review. The LBNL LDRD program is a critical tool for directing the Laboratory's forefront scientific research capabilities toward vital, excellent, and emerging scientific challenges. The program providesmore » the resources for LBNL scientists to make rapid and significant contributions to critical national science and technology problems. The LDRD program also advances LBNL's core competencies, foundations, and scientific capability, and permits exploration of exciting new opportunities. All projects are work in forefront areas of science and technology. Areas eligible for support include the following: Advanced study of hypotheses, concepts, or innovative approaches to scientific or technical problems; Experiments and analyses directed toward ''proof of principle'' or early determination of the utility of new scientific ideas, technical concepts, or devices; and Conception and preliminary technical analyses of experimental facilities or devices.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kupriyanov, M. S., E-mail: mikhail.kupriyanov@gmail.com; Shukeilo, E. Y., E-mail: eyshukeylo@gmail.com; Shichkina, J. A., E-mail: strange.y@mail.ru
2015-11-17
Nowadays technologies which are used in traumatology are a combination of mechanical, electronic, calculating and programming tools. Relevance of development of mobile applications for an expeditious data processing which are received from medical devices (in particular, wearable devices), and formulation of management decisions increases. Using of a mathematical method of building of decision trees for an assessment of a patient’s health condition using data from a wearable device considers in this article.
NASA Astrophysics Data System (ADS)
Kupriyanov, M. S.; Shukeilo, E. Y.; Shichkina, J. A.
2015-11-01
Nowadays technologies which are used in traumatology are a combination of mechanical, electronic, calculating and programming tools. Relevance of development of mobile applications for an expeditious data processing which are received from medical devices (in particular, wearable devices), and formulation of management decisions increases. Using of a mathematical method of building of decision trees for an assessment of a patient's health condition using data from a wearable device considers in this article.
Passive device based on plastic optical fibers to determine the indices of refraction of liquids.
Zubia, J; Garitaonaindía, G; Arrúe, J
2000-02-20
We have designed and measured a passive device based on plastic optical fibers (POF's) that one can use to determine the indices of refraction of liquids. A complementary software has also been designed to simulate the behavior of the device. We report on the theoretical model developed for the device, its implementation in a simulation software program, and the results of the simulation. A comparison of the experimental and calculated results is also shown and discussed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
2014-12-04
The software serves two purposes. The first purpose of the software is to prototype the Sandia High Performance Computing Power Application Programming Interface Specification effort. The specification can be found at http://powerapi.sandia.gov . Prototypes of the specification were developed in parallel with the development of the specification. Release of the prototype will be instructive to anyone who intends to implement the specification. More specifically, our vendor collaborators will benefit from the availability of the prototype. The second is in direct support of the PowerInsight power measurement device, which was co-developed with Penguin Computing. The software provides a cluster wide measurementmore » capability enabled by the PowerInsight device. The software can be used by anyone who purchases a PowerInsight device. The software will allow the user to easily collect power and energy information of a node that is instrumented with PowerInsight. The software can also be used as an example prototype implementation of the High Performance Computing Power Application Programming Interface Specification.« less
Test devices for aeronautical research and technology
NASA Technical Reports Server (NTRS)
1985-01-01
The objectives of the DFVLR in six areas are described: (1) transportation and communication systems; (2) aircraft, space technology, (4) remote sensing, (5) energy and propulsion technology; and (6) research and development. A detailed description of testing devices and other facilities required to carry out the research program is given.
Computer Augmented Learning; A Survey.
ERIC Educational Resources Information Center
Kindred, J.
The report contains a description and summary of computer augmented learning devices and systems. The devices are of two general types programed instruction systems based on the teaching machines pioneered by Pressey and developed by Skinner, and the so-called "docile" systems that permit greater user-direction with the computer under student…
Dong, Shufang; Lu, Ke-Qian; Sun, Jian Qiao; Rudolph, Katherine
2006-03-01
In rehabilitation from neuromuscular trauma or injury, strengthening exercises are often prescribed by physical therapists to recover as much function as possible. Strengthening equipment used in clinical settings range from low-cost devices, such as sandbag weights or elastic bands to large and expensive isotonic and isokinetic devices. The low-cost devices are incapable of measuring strength gains and apply resistance based on the lowest level of torque that is produced by a muscle group. Resistance that varies with joint angle can be achieved with isokinetic devices in which angular velocity is held constant and variable torque is generated when the patient attempts to move faster than the device but are ineffective if a patient cannot generate torque rapidly. In this paper, we report the development of a versatile rehabilitation device that can be used to strengthen different muscle groups based on the torque generating capability of the muscle that changes with joint angle. The device is low cost, is smaller than other commercially available machines, and can be programmed to apply resistance that is unique to a particular patient and that will optimize strengthening. The core of the device, a damper with smart magnetorheological fluids, provides passive exercise force. A digital adaptive control is capable of regulating exercise force precisely following the muscle strengthening profile prescribed by a physical therapist. The device could be programmed with artificial intelligence to dynamically adjust the target force profile to optimize rehabilitation effects. The device provides both isometric and isokinetic strength training and can be developed into a small, low-cost device that may be capable of providing optimal strengthening in the home.
Silicon carbide, an emerging high temperature semiconductor
NASA Technical Reports Server (NTRS)
Matus, Lawrence G.; Powell, J. Anthony
1991-01-01
In recent years, the aerospace propulsion and space power communities have expressed a growing need for electronic devices that are capable of sustained high temperature operation. Applications for high temperature electronic devices include development instrumentation within engines, engine control, and condition monitoring systems, and power conditioning and control systems for space platforms and satellites. Other earth-based applications include deep-well drilling instrumentation, nuclear reactor instrumentation and control, and automotive sensors. To meet the needs of these applications, the High Temperature Electronics Program at the Lewis Research Center is developing silicon carbide (SiC) as a high temperature semiconductor material. Research is focussed on developing the crystal growth, characterization, and device fabrication technologies necessary to produce a family of silicon carbide electronic devices and integrated sensors. The progress made in developing silicon carbide is presented, and the challenges that lie ahead are discussed.
Assurance of Complex Electronics. What Path Do We Take?
NASA Technical Reports Server (NTRS)
Plastow, Richard A.
2007-01-01
Many of the methods used to develop software bare a close resemblance to Complex Electronics (CE) development. CE are now programmed to perform tasks that were previously handled in software, such as communication protocols. For instance, Field Programmable Gate Arrays (FPGAs) can have over a million logic gates while system-on-chip (SOC) devices can combine a microprocessor, input and output channels, and sometimes an FPGA for programmability. With this increased intricacy, the possibility of "software-like" bugs such as incorrect design, logic, and unexpected interactions within the logic is great. Since CE devices are obscuring the hardware/software boundary, we propose that mature software methodologies may be utilized with slight modifications to develop these devices. By using standardized S/W Engineering methods such as checklists, missing requirements and "bugs" can be detected earlier in the development cycle, thus creating a development process for CE that will be easily maintained and configurable based on the device used.
2009-09-01
Tele-maintenance Capability with Remote Serial Console Access and Proactive Monitoring of Medical Devices PRINCIPAL INVESTIGATOR...Remote Serial Console Access and Proactive Monitoring of Medical Devices 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d...ORGANIZATION REPORT NUMBER Concepteers LLC 880 Bergen Avenue, Suite 403 Jersey City, NJ 07306 9. SPONSORING / MONITORING
1991-01-01
EXPERIENCE IN DEVELOPING INTEGRATED OPTICAL DEVICES, NONLINEAR MAGNETIC-OPTIC MATERIALS, HIGH FREQUENCY MODULATORS, COMPUTER-AIDED MODELING AND SOPHISTICATED... HIGH -LEVEL PRESENTATION AND DISTRIBUTED CONTROL MODELS FOR INTEGRATING HETEROGENEOUS MECHANICAL ENGINEERING APPLICATIONS AND TOOLS. THE DESIGN IS FOCUSED...STATISTICALLY ACCURATE WORST CASE DEVICE MODELS FOR CIRCUIT SIMULATION. PRESENT METHODS OF WORST CASE DEVICE DESIGN ARE AD HOC AND DO NOT ALLOW THE
Silicon Processors Using Organically Reconfigurable Techniques (SPORT)
2014-05-19
towards producing SWPC devices. ATR measurements on these thin films reveal a 30% increase in the EO activity of the OEOM films after thermal ...poling and recover about 50% the EO activity of thermally -poled films without poling. A simple proof-of-concept device architecture was fabricated and...device in peer-reviewed literature. New organic EO host materials developed at UD for the SPORT program offer increased thermal stability and EO
Aungst, Timothy Dy; Belliveau, Paul
2015-01-01
As mobile smart device use has increased in society, the healthcare community has begun using these devices for communication among professionals in practice settings. The purpose of this review is to describe primary literature which reports on the experiences with interprofessional healthcare communication via mobile smart devices. Based on these findings, this review also addresses how these devices may be utilized to facilitate interprofessional education (IPE) in health professions education programs. The literature search revealed limited assessments of mobile smart device use in clinical practice settings. In available reports, communication with mobile smart devices was perceived as more effective and faster among interdisciplinary members. Notable drawbacks included discrepancies in the urgency labeling of messages, increased interruptions associated with constant accessibility to team members, and professionalism breakdowns. Recently developed interprofessional competencies include an emphasis on ensuring that health profession students can effectively communicate on interprofessional teams. With the increasing reliance on mobile smart devices in the absence of robust benefit and risk assessments on their use in clinical practice settings, use of these devices may be leveraged to facilitate IPE activities in health education professions programs while simultaneously educating students on their proper use in patient care settings.
An Accessible User Interface for Geoscience and Programming
NASA Astrophysics Data System (ADS)
Sevre, E. O.; Lee, S.
2012-12-01
The goal of this research is to develop an interface that will simplify user interaction with software for scientists. The motivating factor of the research is to develop tools that assist scientists with limited motor skills with the efficient generation and use of software tools. Reliance on computers and programming is increasing in the world of geology, and it is increasingly important for geologists and geophysicists to have the computational resources to use advanced software and edit programs for their research. I have developed a prototype of a program to help geophysicists write programs using a simple interface that requires only simple single-mouse-clicks to input code. It is my goal to minimize the amount of typing necessary to create simple programs and scripts to increase accessibility for people with disabilities limiting fine motor skills. This interface can be adapted for various programming and scripting languages. Using this interface will simplify development of code for C/C++, Java, and GMT, and can be expanded to support any other text based programming language. The interface is designed around the concept of maximizing the amount of code that can be written using a minimum number of clicks and typing. The screen is split into two sections: a list of click-commands is on the left hand side, and a text area is on the right hand side. When the user clicks on a command on the left hand side the applicable code is automatically inserted at the insertion point in the text area. Currently in the C/C++ interface, there are commands for common code segments that are often used, such as for loops, comments, print statements, and structured code creation. The primary goal is to provide an interface that will work across many devices for developing code. A simple prototype has been developed for the iPad. Due to the limited number of devices that an iOS application can be used with, the code has been re-written in Java to run on a wider range of devices. Currently, the software works in a prototype mode, and it is our goal to further development to create software that can benefit a wide range of people working in geosciences, which will make code development practical and accessible for a wider audience of scientists. By using an interface like this, it reduces potential for errors by reusing known working code.
Crystal growth of device quality GaAs in space
NASA Technical Reports Server (NTRS)
Gatos, H. C.; Lagowski, J.
1985-01-01
The present program has been aimed at solving the fundamental and technological problems associated with Crystal Growth of Device Quality in Space. The initial stage of the program was devoted strictly to ground-based research. The unsolved problems associated with the growth of bulk GaAs in the presence of gravitational forces were explored. Reliable chemical, structural and electronic characterization methods were developed which would permit the direct relation of the salient materials parameters (particularly those affected by zero gravity conditions) to the electronic characteristics of single crystal GaAs, in turn to device performance. These relationships are essential for the development of optimum approaches and techniques. It was concluded that the findings on elemental semiconductors Ge and Si regarding crystal growth, segregation, chemical composition, defect interactions, and materials properties-electronic properties relationships are not necessarily applicable to GaAs (and to other semiconductor compounds). In many instances totally unexpected relationships were found to prevail.
Keena, Cecilia; Rossetto, Jorge; Somoza, Matías; De Lellis, Martín
2017-01-01
The psychiatric hospital "Dr. Manuel A. Montes de Oca" has developed a Program for the Reform of the Model of Attention and Integral Rehabilitation that includes the implantation of community residential devices in the area of influence of the Institution. This program, which aims at the progressive replacement of asylum beds, has been the subject of an evaluative investigation that has included almost all the devices through a transversal and descriptive design, with instruments of survey created by the equipment and in agreement with the References of the Institution. The present article proposes to initiate a set of evaluative works in different dimensions concerning the institutional reform process, describing the antecedents, the objectives and the methodology and development of the study to achieve the general characterization of the devices. The main results of the study are summarized below on a set of aspects that we consider most signifcant for the characterization of the devices: a) Type of users served; B) Coverage of Care; C) Method of approach; D) Use of social and health services; E) Expenses and returns to the Institution; E) Main barriers encountered in the implementation of such devices. The work concludes with a series of proposals that are based on the survey carried out tending to promote the greatest possible sustainability in the implementation of the selected community devices.
Sensory Aids Research Project - Clarke School for the Deaf.
ERIC Educational Resources Information Center
Boothroyd, Arthur
Described is a program of research into sensory aids for the deaf, emphasizing research on factors involved in the effective use of sensory aids rather than evaluation of particular devices. Aspects of the program are the development of a programed testing and training unit, the control of fundamental voice frequency using visual feedback, and…
Design and analysis of DNA strand displacement devices using probabilistic model checking
Lakin, Matthew R.; Parker, David; Cardelli, Luca; Kwiatkowska, Marta; Phillips, Andrew
2012-01-01
Designing correct, robust DNA devices is difficult because of the many possibilities for unwanted interference between molecules in the system. DNA strand displacement has been proposed as a design paradigm for DNA devices, and the DNA strand displacement (DSD) programming language has been developed as a means of formally programming and analysing these devices to check for unwanted interference. We demonstrate, for the first time, the use of probabilistic verification techniques to analyse the correctness, reliability and performance of DNA devices during the design phase. We use the probabilistic model checker prism, in combination with the DSD language, to design and debug DNA strand displacement components and to investigate their kinetics. We show how our techniques can be used to identify design flaws and to evaluate the merits of contrasting design decisions, even on devices comprising relatively few inputs. We then demonstrate the use of these components to construct a DNA strand displacement device for approximate majority voting. Finally, we discuss some of the challenges and possible directions for applying these methods to more complex designs. PMID:22219398
Krishnan, Shankar
2013-01-01
The worldwide need for rapid expansion and diversification of medical devices and the corresponding requirements in industry pose arduous challenges for educators to train undergraduate biomedical engineering (BME) students. Preparing BME students for working in the research and development (R&D) in medical device industry is not easily accomplished by adopting traditional pedagogical methods. Even with the inclusion of the design and development elements in capstone projects, medical device industry may be still experience a gap in fulfilling their needs in R&D. This paper proposes a new model based on interdisciplinary project-based learning (IDPBL) to address the requirements of building the necessary skill sets in academia for carrying out R&D in medical device industry. The proposed model incorporates IDPBL modules distributed in a stepwise fashion through the four years of a typical BME program. The proposed model involves buy-in and collaboration from faculty as well as students. The implementation of the proposed design in an undergraduate BME program is still in process. However, a variant of the proposed IDPBL method has been attempted at a limited scale at the postgraduate level and has shown some success. Extrapolating the previous results, the adoption of the IDPBL to BME training seems to suggest promising outcomes. Despite numerous implementation challenges, with continued efforts, the proposed IDPBL will be valuable n academia for skill sets building for medical device R&D.
Active cleaning technique device
NASA Technical Reports Server (NTRS)
Shannon, R. L.; Gillette, R. B.
1973-01-01
The objective of this program was to develop a laboratory demonstration model of an active cleaning technique (ACT) device. The principle of this device is based primarily on the technique for removing contaminants from optical surfaces. This active cleaning technique involves exposing contaminated surfaces to a plasma containing atomic oxygen or combinations of other reactive gases. The ACT device laboratory demonstration model incorporates, in addition to plasma cleaning, the means to operate the device as an ion source for sputtering experiments. The overall ACT device includes a plasma generation tube, an ion accelerator, a gas supply system, a RF power supply and a high voltage dc power supply.
NASA Astrophysics Data System (ADS)
Shichkina, Y. A.; Kupriyanov, M. S.; Moldachev, S. O.
2018-05-01
Today, a description of various Internet devices very often appears on the Internet. For the efficient operation of the Industrial Internet of things, it is necessary to provide a modern level of data processing starting from getting them from devices ending with returning them to devices in a processed form. Current solutions of the Internet of Things are mainly focused on the development of centralized decisions, projecting the Internet of Things on the set of cloud-based platforms that are open, but limit the ability of participants of the Internet of Things to adapt these systems to their own problems. Therefore, it is often necessary to create specialized software for specific areas of the Internet of Things. This article describes the solution of the problem of virtualization of the system of devices based on the Docker system. This solution allows developers to test any software on any number of devices forming a mesh.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dupuis, Russell
The goal of this program is to understand in a fundamental way the impact of strain, defects, polarization, and Stokes loss in relation to unique device structures upon the internal quantum efficiency (IQE) and efficiency droop (ED) of III-nitride (III-N) light-emitting diodes (LEDs) and to employ this understanding in the design and growth of high-efficiency LEDs capable of highly-reliable, high-current, high-power operation. This knowledge will be the basis for our advanced device epitaxial designs that lead to improved device performance. The primary approach we will employ is to exploit new scientific and engineering knowledge generated through the application of amore » set of unique advanced growth and characterization tools to develop new concepts in strain-, polarization-, and carrier dynamics-engineered and low-defect materials and device designs having reduced dislocations and improved carrier collection followed by efficient photon generation. We studied the effects of crystalline defect, polarizations, hole transport, electron-spillover, electron blocking layer, underlying layer below the multiplequantum- well active region, and developed high-efficiency and efficiency-droop-mitigated blue LEDs with a new LED epitaxial structures. We believe new LEDs developed in this program will make a breakthrough in the development of high-efficiency high-power visible III-N LEDs from violet to green spectral region.« less
TealLock 5.20 security software program for handheld devices.
Tahil, Fatimah A
2004-07-01
The TealLock has a simple graphic interface, and the program is user-friendly with well thought out options to customize security settings. The program is inexpensive and works seamlessly with the Palm OS platform's built-in basic Security application. The developer offers a 30-day free trial version and there is no downside to trying it to see if it meets your needs. It seems to be an effective security software program for psychiatrists who keep confidential and sensitive patient information on their PDAs. In keeping with HIPAA regulations, the TealLock bolsters security for protected health information stored on PDAs or other handheld devices by providing safeguards that address authentication, access control, encryption, and selected aspects of transmission.
NASA photovoltaic research and technology
NASA Technical Reports Server (NTRS)
Flood, Dennis J.
1988-01-01
NASA photovoltaic R and D efforts address future Agency space mission needs through a comprehensive, integrated program. Activities range from fundamental studies of materials and devices to technology demonstrations of prototype hardware. The program aims to develop and apply an improved understanding of photovoltaic energy conversion devices and systems that will increase the performance, reduce the mass, and extend the lifetime of photovoltaic arrays for use in space. To that end, there are efforts aimed at improving cell efficiency, reducing the effects of space particulate radiation damage (primarily electrons and protons), developing ultralightweight cells, and developing advanced ray component technology for high efficiency concentrator arrays and high performance, ultralightweight arrays. Current goals that have been quantified for the program are to develop cell and array technology capable of achieving 300 watts/kg for future missions for which mass is a critical factor, or 300 watts/sq m for future missions for which array size is a major driver (i.e., Space Station). A third important goal is to develop cell and array technology which will survive the GEO space radiation environment for at least 10 years.
Martin, Timothy; Ding, Hang; D'Souza, Matthew; Karunanithi, Mohan
2012-01-01
Cardiovascular disease (CVD) is the leading cause of mortality in Australia, and places large burdens on the healthcare system. To assist patients with CVDs in recovering from cardiac events and mediating cardiac risk factors, a home based cardiac rehabilitation program, known as the Care Assessment Platform (CAP), was developed. In the CAP program, patients are required to manually enter health information into their mobile phones on a daily basis. The manual operation is often subject to human errors and is inconvenient for some elderly patients. To improve this, an automated wireless solution has been desired. The objectives of this paper are to investigate the feasibility of implementing the newly released Bluetooth 4.0 (BT4.0) for the CAP program, and practically evaluate BT4.0 communications between a developed mobile application and some emulated healthcare devices. The study demonstrated that BT4.0 addresses usability, interoperability and security for healthcare applications, reduces the power consumption in wireless communication, and improves the flexibility of interface for software development. This evaluation study provides an essential mobile BT4.0 framework to incorporate a large range of healthcare devices for clinical assessment and intervention in the CAP program, and hence it is useful for similar development and research work of other mobile healthcare solutions.
Surface acoustic wave devices for sensor applications
NASA Astrophysics Data System (ADS)
Bo, Liu; Xiao, Chen; Hualin, Cai; Mohammad, Mohammad Ali; Xiangguang, Tian; Luqi, Tao; Yi, Yang; Tianling, Ren
2016-02-01
Surface acoustic wave (SAW) devices have been widely used in different fields and will continue to be of great importance in the foreseeable future. These devices are compact, cost efficient, easy to fabricate, and have a high performance, among other advantages. SAW devices can work as filters, signal processing units, sensors and actuators. They can even work without batteries and operate under harsh environments. In this review, the operating principles of SAW sensors, including temperature sensors, pressure sensors, humidity sensors and biosensors, will be discussed. Several examples and related issues will be presented. Technological trends and future developments will also be discussed. Project supported by the National Natural Science Foundation of China (Nos. 60936002, 61025021, 61434001, 61574083), the State Key Development Program for Basic Research of China (No. 2015CB352100), the National Key Project of Science and Technology (No. 2011ZX02403-002) and the Special Fund for Agroscientific Research in the Public Interest of China (No. 201303107). M.A.M is additionally supported by the Postdoctoral Fellowship (PDF) program of the Natural Sciences and Engineering Research Council (NSERC) of Canada and the China Postdoctoral Science Foundation (CPSF).
Nuclear and Radiological Forensics and Attribution Overview
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smith, D K; Niemeyer, S
2005-11-04
The goal of the U.S. Department of Homeland Security (DHS) Nuclear and Radiological Forensics and Attribution Program is to develop the technical capability for the nation to rapidly, accurately, and credibly attribute the origins and pathways of interdicted or collected materials, intact nuclear devices, and radiological dispersal devices. A robust attribution capability contributes to threat assessment, prevention, and deterrence of nuclear terrorism; it also supports the Federal Bureau of Investigation (FBI) in its investigative mission to prevent and respond to nuclear terrorism. Development of the capability involves two major elements: (1) the ability to collect evidence and make forensic measurements,more » and (2) the ability to interpret the forensic data. The Program leverages the existing capability throughout the U.S. Department of Energy (DOE) national laboratory complex in a way that meets the requirements of the FBI and other government users. At the same time the capability is being developed, the Program also conducts investigations for a variety of sponsors using the current capability. The combination of operations and R&D in one program helps to ensure a strong linkage between the needs of the user community and the scientific development.« less
Design, fabrication, testing, and delivery of improved beam steering devices
NASA Technical Reports Server (NTRS)
1973-01-01
The development, manufacture, and testing of an optical steerer intended for use in spaceborne optical radar systems are described. Included are design principles and design modifications made to harden the device against launch and space environments, the quality program and procedures developed to insure consistent product quality throughout the manufacturing phase, and engineering qualification model testing and evaluation. The delivered hardware design is considered conditionally qualified pending action on further recommended design modifications.
NASA Astrophysics Data System (ADS)
Younis, Adnan; Chu, Dewei; Li, Sean
2015-09-01
Further progress in high-performance microelectronic devices relies on the development of novel materials and device architectures. However, the components and designs that are currently in use have reached their physical limits. Intensive research efforts, ranging from device fabrication to performance evaluation, are required to surmount these limitations. In this paper, we demonstrate that the superior bipolar resistive switching characteristics of a CeO2:Gd-based memory device can be manipulated by means of UV radiation, serving as a new degree of freedom. Furthermore, the metal oxide-based (CeO2:Gd) memory device was found to possess electrical and neuromorphic multifunctionalities. To investigate the underlying switching mechanism of the device, its plasticity behaviour was studied by imposing weak programming conditions. In addition, a short-term to long-term memory transition analogous to the forgetting process in the human brain, which is regarded as a key biological synaptic function for information processing and data storage, was realized. Based on a careful examination of the device’s retention behaviour at elevated temperatures, the filamentary nature of switching in such devices can be understood from a new perspective.
Younis, Adnan; Chu, Dewei; Li, Sean
2015-01-01
Further progress in high-performance microelectronic devices relies on the development of novel materials and device architectures. However, the components and designs that are currently in use have reached their physical limits. Intensive research efforts, ranging from device fabrication to performance evaluation, are required to surmount these limitations. In this paper, we demonstrate that the superior bipolar resistive switching characteristics of a CeO2:Gd-based memory device can be manipulated by means of UV radiation, serving as a new degree of freedom. Furthermore, the metal oxide-based (CeO2:Gd) memory device was found to possess electrical and neuromorphic multifunctionalities. To investigate the underlying switching mechanism of the device, its plasticity behaviour was studied by imposing weak programming conditions. In addition, a short-term to long-term memory transition analogous to the forgetting process in the human brain, which is regarded as a key biological synaptic function for information processing and data storage, was realized. Based on a careful examination of the device’s retention behaviour at elevated temperatures, the filamentary nature of switching in such devices can be understood from a new perspective. PMID:26324073
Computer Programs For Automated Welding System
NASA Technical Reports Server (NTRS)
Agapakis, John E.
1993-01-01
Computer programs developed for use in controlling automated welding system described in MFS-28578. Together with control computer, computer input and output devices and control sensors and actuators, provide flexible capability for planning and implementation of schemes for automated welding of specific workpieces. Developed according to macro- and task-level programming schemes, which increases productivity and consistency by reducing amount of "teaching" of system by technician. System provides for three-dimensional mathematical modeling of workpieces, work cells, robots, and positioners.
Simulation-based instruction of technical skills
NASA Technical Reports Server (NTRS)
Towne, Douglas M.; Munro, Allen
1991-01-01
A rapid intelligent tutoring development system (RAPIDS) was developed to facilitate the production of interactive, real-time graphical device models for use in instructing the operation and maintenance of complex systems. The tools allowed subject matter experts to produce device models by creating instances of previously defined objects and positioning them in the emerging device model. These simulation authoring functions, as well as those associated with demonstrating procedures and functional effects on the completed model, required no previous programming experience or use of frame-based instructional languages. Three large simulations were developed in RAPIDS, each involving more than a dozen screen-sized sections. Seven small, single-view applications were developed to explore the range of applicability. Three workshops were conducted to train others in the use of the authoring tools. Participants learned to employ the authoring tools in three to four days and were able to produce small working device models on the fifth day.
The Medical Devices Special Access Program in Canada: A Scoping Study
Menon, Devidas; Stafinski, Tania
2018-01-01
New health technologies enter Canadian healthcare organizations in various ways, and understanding them is essential to the development of a pan-Canadian Health Technology Management (HTM) Strategy, now a priority of governments across Canada. One way is through Health Canada's Medical Devices Special Access Program (MDSAP), which permits unlicensed devices to be obtained by healthcare professionals. However, the circumstances around and implications of the current use of this program are not clear. A scoping literature review was conducted to clarify these and identify important roles and issues related to the MDSAP. Limited information was found on the MDSAP. Nevertheless, three themes demonstrating the roles of the MDSAP in HTM emerged: arbiter in technology selection, a route to technology procurement and facilitator of health technology innovation. No information suggesting that MDSAP is used to circumvent licensing was found. Rather, it enables desired patient outcomes and product commercialization. PMID:29595436
NASA Astrophysics Data System (ADS)
Knudson, Christa K.; Kemp, Michael C.; Lombardo, Nicholas J.
2009-05-01
The U.S. Department of Homeland Security's Standoff Technology Integration and Demonstration Program is designed to accelerate the development and integration of technologies, concepts of operations, and training to defeat explosives attacks at large public events and mass transit facilities. The program will address threats posed by suicide bombers, vehicle-borne improvised explosive devices, and leave-behind bombs. The program is focused on developing and testing explosives countermeasure architectures using commercial off-the-shelf and near-commercial standoff and remotely operated detection technologies in prototypic operational environments. An important part of the program is the integration of multiple technologies and systems to protect against a wider range of threats, improve countermeasure performance, increase the distance from the venue at which screening is conducted, and reduce staffing requirements. The program will routinely conduct tests in public venues involving successively more advanced technology, higher levels of system integration, and more complex scenarios. This paper describes the initial field test of an integrated countermeasure system that included infrared, millimeter-wave, and video analytics technologies for detecting person-borne improvised explosive devices at a public arena. The test results are being used to develop a concept for the next generation of integrated countermeasures, to refine technical and operational requirements for architectures and technologies, and engage industry and academia in solution development.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Knudson, Christa K.; Kemp, Michael C.; Lombardo, Nicholas J.
The Department of Homeland Security’s Standoff Technology Integration and Demonstration Program is designed to accelerate the development and integration of technologies, concepts of operations, and training to prevent explosives attacks at large public events and mass transit facilities. The program will address threats posed by suicide bombers, vehicle-borne improvised explosive devices, and leave-behind bombs. The program is focused on developing and testing explosives countermeasure architectures using commercial off-the-shelf and near-commercial standoff and remotely operated detection technologies in prototypic operational environments. An important part of the program is the integration of multiple technologies and systems to protect against a wider rangemore » of threats, improve countermeasure performance, increase the distance from the venue at which screening is conducted, and reduce staffing requirements. The program will routinely conduct tests in public venues involving successively more advanced technology, higher levels of system integration, and more complex scenarios. This paper describes the initial field test of an integrated countermeasure system that included infrared, millimeter-wave, and video analytics technologies for detecting person-borne improvised explosive devices at a public arena. The test results are being used to develop a concept for the next generation of integrated countermeasures, to refine technical and operational requirements for architectures and technologies, and engage industry and academia in solution development.« less
Developing a protocol for creating microfluidic devices with a 3D printer, PDMS, and glass
NASA Astrophysics Data System (ADS)
Collette, Robyn; Novak, Eric; Shirk, Kathryn
2015-03-01
Microfluidics research requires the design and fabrication of devices that have the ability to manipulate small volumes of fluid, typically ranging from microliters to picoliters. These devices are used for a wide range of applications including the assembly of materials and testing of biological samples. Many methods have been previously developed to create microfluidic devices, including traditional nanolithography techniques. However, these traditional techniques are cost-prohibitive for many small-scale laboratories. This research explores a relatively low-cost technique using a 3D printed master, which is used as a template for the fabrication of polydimethylsiloxane (PDMS) microfluidic devices. The masters are designed using computer aided design (CAD) software and can be printed and modified relatively quickly. We have developed a protocol for creating simple microfluidic devices using a 3D printer and PDMS adhered to glass. This relatively simple and lower-cost technique can now be scaled to more complicated device designs and applications. Funding provided by the Undergraduate Research Grant Program at Shippensburg University and the Student/Faculty Research Engagement Grants from the College of Arts and Sciences at Shippensburg University.
ERIC Educational Resources Information Center
Joint Publications Research Service, Washington, DC.
THIS REVIEW REPORTS THE STATE OF THE ART OF PROGRAMED INSTRUCTION IN THE SOVIET UNION. A NUMBER OF TEACHING MACHINES ARE DESCRIBED, AS ARE PROJECTED DEVELOPMENTS IN SOVIET PROGRAMED INSTRUCTION. IT IS EXPECTED THAT THE 4TH ALL-RUSSIAN CONFERENCE ON THE APPLICATION OF TECHNICAL DEVICES AND PROGRAMING IN EDUCATION (JAN. 1964) WILL PROVIDE FURTHER…
The design of electron and ion guns, beams, and collectors
NASA Astrophysics Data System (ADS)
Becker, Reinard; Herrmannsfeldt, William B.
2004-01-01
The well known `SLAC Electron Trajectory Program' (EGUN) has been ported to PCs and has been developed into a family of programs for the design and the optimization of particle optics devices including electron and ion guns, beam transport sections and collectors. We will discuss the application of these tools for the design and the optimization of the essential parts of EBIS/T devices. The discussion will include conditions in which restrictions in the reliability of simulations may occur due to the mathematical modeling and how to overcome them.
Experimental Performance of the NRL 8-Beam, 4-Cavity Multiple-Beam Klystron
NASA Astrophysics Data System (ADS)
Abe, D. K.; Pershing, D. E.; Nguyen, K. T.; Wood, F. N.; Myers, R. E.; Eisen, E. L.; Cusick, M.; Levush, B.
2006-01-01
Multiple-beam amplifiers (MBAs) represent a device technology with the potential to produce high-power, efficient amplifiers with relatively wide bandwidths that are compact, low-weight, low-noise, and operate at reduced voltages relative to comparable single-beam devices. To better understand the device physics and technical issues involved in the design, fabrication, and operation of these devices, the U.S. Naval Research Laboratory (NRL) has an on-going program to develop high peak power (> 600 kW) multiple-beam klystrons (MBKs) operating in S-band (˜3.3 GHz).
Workplace Training Programs: Instruments for Human Capital Improvements or Screening Devices?
ERIC Educational Resources Information Center
Brunetti, Irene; Corsini, Lorenzo
2017-01-01
Purpose: The purpose of this paper is to analyse the effect of an Italian training program on the re-employment probability of young unemployed workers. The program consists exclusively of workplace training and is coordinated by employment centers, even if it is fully implemented by firms. Design/Methodology/Approach: The authors develop a…
Jones, Stephanie B; Munro, Malcolm G; Feldman, Liane S; Robinson, Thomas N; Brunt, L Michael; Schwaitzberg, Steven D; Jones, Daniel B; Fuchshuber, Pascal R
2017-01-01
Operating room (OR) safety has become a major concern in patient safety since the 1990s. Improvement of team communication and behavior is a popular target for safety programming at the institutional level. Despite these efforts, essential safety gaps remain in the OR and procedure rooms. A prime example is the use of energy-based devices in ORs and procedural areas. The lack of fundamental understanding of energy device function, design, and application contributes to avoidable injury and harm at a rate of approximately 1 to 2 per 1000 patients in the US. Hundreds of OR fires occur each year in the US, some causing severe injury and even death. Most of these fires are associated with the use of energy-based surgical devices. In response to this safety issue, the Society of American Gastrointestinal and Endoscopic Surgeons (SAGES) developed the Fundamental Use of Surgical Energy (FUSE) program. This program includes a standardized curriculum targeted to surgeons, other physicians, and allied health care professionals and a psychometrically designed and validated certification test. A successful FUSE certification documents acquisition of the basic knowledge needed to safely use energy-based devices in the OR. By design FUSE fills a void in the curriculum and competency assessment for surgeons and other procedural specialists in the use of energy-based devices in patients. PMID:28241913
ERIC Educational Resources Information Center
Moon, Daniel
2002-01-01
Advises schools on how to establish an automated external defibrillator (AED) program. These laptop-size devices can save victims of sudden cardiac arrest by delivering an electrical shock to return the heartbeat to normal. Discusses establishing standards, developing a strategy, step-by-step advice towards establishing an AED program, and school…
ERIC Educational Resources Information Center
LEBEDEV, P.D.
ON THE PREMISES THAT THE DEVELOPMENT OF PROGRAMED LEARNING BY RESEARCH TEAMS OF SUBJECT AND TECHNIQUE SPECIALISTS IS INDISPUTABLE, AND THAT THE EXPERIENCED TEACHER IN THE ROLE OF INDIVIDUAL TUTOR IS INDISPENSABLE, THE TECHNOLOGY TO SUPPORT PROGRAMED INSTRUCTION MUST BE ADVANCED. AUTOMATED DEVICES EMPLOYING SEQUENTIAL AND BRANCHING TECHNIQUES FOR…
An interactive computer program for sizing spacecraft momentum storage devices
NASA Technical Reports Server (NTRS)
Wilcox, F. J., Jr.
1980-01-01
An interactive computer program was developed which computes the sizing requirements for nongimbled reaction wheels, control moment gyros (CMG), and dual momentum control devices (DMCD) used in Earth-orbiting spacecraft. The program accepts as inputs the spacecraft's environmental disturbance torques, rotational inertias, maneuver rates, and orbital data. From these inputs, wheel weights are calculated for a range of radii and rotational speeds. The shape of the momentum wheel may be chosen to be either a hoop, solid cylinder, or annular cylinder. The program provides graphic output illustrating the trade-off potential between the weight, radius, and wheel speed. A number of the intermediate calculations such as the X-, Y-, and Z-axis total momentum, the momentum absorption requirements for reaction wheels, CMG's, DMCD's, and basic orbit analysis information are also provided as program output.
GaN Initiative for Grid Applications (GIGA)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Turner, George
2015-07-03
For nearly 4 ½ years, MIT Lincoln Laboratory (MIT/LL) led a very successful, DoE-funded team effort to develop GaN-on-Si materials and devices, targeting high-voltage (>1 kV), high-power, cost-effective electronics for grid applications. This effort, called the GaN Initiative for Grid Applications (GIGA) program, was initially made up of MIT/LL, the MIT campus group of Prof. Tomas Palacios (MIT), and the industrial partner M/A Com Technology Solutions (MTS). Later in the program a 4th team member was added (IQE MA) to provide commercial-scale GaN-on-Si epitaxial materials. A basic premise of the GIGA program was that power electronics, for ubiquitous utilization -evenmore » for grid applications - should be closer in cost structure to more conventional Si-based power electronics. For a number of reasons, more established GaN-on-SiC or even SiC-based power electronics are not likely to reach theses cost structures, even in higher manufacturing volumes. An additional premise of the GIGA program was that the technical focus would be on materials and devices suitable for operating at voltages > 1 kV, even though there is also significant commercial interest in developing lower voltage (< 1 kV), cost effective GaN-on-Si devices for higher volume applications, like consumer products. Remarkable technical progress was made during the course of this program. Advances in materials included the growth of high-quality, crack-free epitaxial GaN layers on large-diameter Si substrates with thicknesses up to ~5 μm, overcoming significant challenges in lattice mismatch and thermal expansion differences between Si and GaN in the actual epitaxial growth process. Such thick epilayers are crucial for high voltage operation of lateral geometry devices such as Schottky barrier (SB) diodes and high electron mobility transistors (HEMTs). New “Normally-Off” device architectures were demonstrated – for safe operation of power electronics circuits. The trade-offs between lateral and vertical devices were explored, with the conclusion that lateral devices are superior for fundamental thermal reasons, as well as for the demonstration of future generations of monolithic power circuits. As part of the materials and device investigations breakdown mechanisms in GaN-on-Si structures were fully characterized and effective electric field engineering was recognized as critical for achieving even higher voltage operation. Improved device contact technology was demonstrated, including the first gold-free metallizations (to enable processing in CMOS foundries) while maintaining low specific contact resistance needed for high-power operation and 5-order-of magnitude improvement in device leakage currents (essential for high power operation). In addition, initial GaN-on-Si epitaxial growth was performed on 8”/200 mm Si starting substrates.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chung, Youngjoo; Kim, Keeman.
1991-01-01
An operating system shell GPDAS (General Purpose Data Acquisition Shell) on MS-DOS-based microcomputers has been developed to provide flexibility in data acquisition and device control for magnet measurements at the Advanced Photon Source. GPDAS is both a command interpreter and an integrated script-based programming environment. It also incorporates the MS-DOS shell to make use of the existing utility programs for file manipulation and data analysis. Features include: alias definition, virtual memory, windows, graphics, data and procedure backup, background operation, script programming language, and script level debugging. Data acquisition system devices can be controlled through IEEE488 board, multifunction I/O board, digitalmore » I/O board and Gespac crate via Euro G-64 bus. GPDAS is now being used for diagnostics R D and accelerator physics studies as well as for magnet measurements. Their hardware configurations will also be discussed. 3 refs., 3 figs.« less
Algorithmic support for graphic images rotation in avionics
NASA Astrophysics Data System (ADS)
Kniga, E. V.; Gurjanov, A. V.; Shukalov, A. V.; Zharinov, I. O.
2018-05-01
The avionics device designing has an actual problem of development and research algorithms to rotate the images which are being shown in the on-board display. The image rotation algorithms are a part of program software of avionics devices, which are parts of the on-board computers of the airplanes and helicopters. Images to be rotated have the flight location map fragments. The image rotation in the display system can be done as a part of software or mechanically. The program option is worse than the mechanic one in its rotation speed. The comparison of some test images of rotation several algorithms is shown which are being realized mechanically with the program environment Altera QuartusII.
[Development of ophthalmologic software for handheld devices].
Grottone, Gustavo Teixeira; Pisa, Ivan Torres; Grottone, João Carlos; Debs, Fernando; Schor, Paulo
2006-01-01
The formulas for calculation of intraocular lenses have evolved since the first theoretical formulas by Fyodorov. Among the second generation formulas, the SRK-I formula has a simple calculation, taking into account a calculation that only involved anteroposterior length, IOL constant and average keratometry. With the evolution of those formulas, complexicity increased making the reconfiguration of parameters in special situations impracticable. In this way the production and development of software for such a purpose, can help surgeons to recalculate those values if needed. To idealize, develop and test a Brazilian software for calculation of IOL dioptric power for handheld computers. For the development and programming of software for calculation of IOL, we used PocketC program (OrbWorks Concentrated Software, USA). We compared the results collected from a gold-standard device (Ultrascan/Alcon Labs) with the simulation of 100 fictitious patients, using the same IOL parameters. The results were grouped for ULTRASCAN data and SOFTWARE data. Using SRK/T formula the range of those parameters included a keratometry varying between 35 and 55D, axial length between 20 and 28 mm, IOL constants of 118.7, 118.3 and 115.8. Using Wilcoxon test, it was shown that the groups do not differ (p=0.314). We had a variation in the Ultrascan sample between 11.82 and 27.97. In the tested program sample the variation was practically similar (11.83-27.98). The average of the Ultrascan group was 20.93. The software group had a similar average. The standard deviation of the samples was also similar (4.53). The precision of IOL software for handheld devices was similar to that of the standard devices using the SRK/T formula. The software worked properly, was steady without bugs in tested models of operational system.
Training program developed for senior undergraduates majoring in optical communication
NASA Astrophysics Data System (ADS)
Cui, Sheng; Zhang, Xinliang; Ke, Changjian
2017-08-01
Based on the well-known simulation software VPI TransmissionMaker, a comprehensive training program for senior undergraduates majoring in optical communication and optical network technology was developed by the author after detailed study of the teaching difficult and key points in the discipline. Aiming at solving practical scientific and engineering problems, the program helped our students to develop the ability of acquiring and applying knowledge by designing optical devices, optical signal processing algorithms and optical fiber communication systems. Furthermore, innovation is inspired by introducing competition mechanism among project teams. The program was validated through four years of use and achieved good results.
A fast and low-power microelectromechanical system-based non-volatile memory device
Lee, Sang Wook; Park, Seung Joo; Campbell, Eleanor E. B.; Park, Yung Woo
2011-01-01
Several new generation memory devices have been developed to overcome the low performance of conventional silicon-based flash memory. In this study, we demonstrate a novel non-volatile memory design based on the electromechanical motion of a cantilever to provide fast charging and discharging of a floating-gate electrode. The operation is demonstrated by using an electromechanical metal cantilever to charge a floating gate that controls the charge transport through a carbon nanotube field-effect transistor. The set and reset currents are unchanged after more than 11 h constant operation. Over 500 repeated programming and erasing cycles were demonstrated under atmospheric conditions at room temperature without degradation. Multinary bit programming can be achieved by varying the voltage on the cantilever. The operation speed of the device is faster than a conventional flash memory and the power consumption is lower than other memory devices. PMID:21364559
1974-05-01
system employs small permanent magnet motors with a small feeding device located on one or both ends of the motor shaft. The feeding device is in...process desired. The permanent magnet motors having system used in these systems have a speed torque curve that is characteristic by a higher torque at the
ERIC Educational Resources Information Center
Kirby, Paul J.; And Others
The design, development, test, and evaluation of an electronic hardware device interfacing a commercially available slide projector with a plasma panel computer terminal is reported. The interface device allows an instructional computer program to select slides for viewing based upon the lesson student situation parameters of the instructional…
Flight Testing of a Low Cost De-Orbiting Device for Small Satellites
NASA Technical Reports Server (NTRS)
Turse, Dana; Keller, Phil; Taylor, Robert; Reavis, Mark; Tupper, Mike; Koehler, Chris
2014-01-01
Use of small and very small spacecraft is rapidly becoming more common. Methods to intentionally deorbit these spacecraft at the end of useful satellite life are required. A family of mass efficient Roll-Out De- Orbiting devices (RODEO"TM") was developed by Composite Technology Development, Inc. (CTD). RODEO"TM" consists of lightweight film attached to a simple, ultra-lightweight, roll-out composite boom structure. This system is rolled to stow within a lightweight launch canister, allowing easy integration to the small satellite bus. The device is released at the end of useful lifetime and the RODEO"TM" composite boom unrolls the drag sail in a matter of seconds. This dramatically increases the deployed surface area, resulting in the higher aerodynamic drag that significantly reduces the time until reentry. A RODEO"TM" flight demonstration was recently conducted as part of the Colorado Space Grant Consortium's (COSGC) RocketSat-8 program, a program to provide students hands-on experience in developing experiments for space flight. The experiment was ultimately a success and RODEO (trademark) is now ready for future CubeSat missions.
Advanced electrical power system technology for the all electric aircraft
NASA Technical Reports Server (NTRS)
Finke, R. C.; Sundberg, G. R.
1983-01-01
The application of advanced electric power system technology to an all electric airplane results in an estimated reduction of the total takeoff gross weight of over 23,000 pounds for a large airplane. This will result in a 5 to 10 percent reduction in direct operating costs (DOC). Critical to this savings is the basic electrical power system component technology. These advanced electrical power components will provide a solid foundation for the materials, devices, circuits, and subsystems needed to satisfy the unique requirements of advanced all electric aircraft power systems. The program for the development of advanced electrical power component technology is described. The program is divided into five generic areas: semiconductor devices (transistors, thyristors, and diodes); conductors (materials and transmission lines); dielectrics; magnetic devices; and load management devices. Examples of progress in each of the five areas are discussed. Bipolar power transistors up to 1000 V at 100 A with a gain of 10 and a 0.5 microsec rise and fall time are presented. A class of semiconductor devices with a possibility of switching up to 100 kV is described. Solid state power controllers for load management at 120 to 1000 V and power levels to 25 kW were developed along with a 25 kW, 20 kHz transformer weighing only 3.2 kg.
Filling the Assurance Gap on Complex Electronics
NASA Technical Reports Server (NTRS)
Plastow, Richard A.
2007-01-01
Many of the methods used to develop software bare a close resemblance to Complex Electronics (CE) development. CE are now programmed to perform tasks that were previously handled by software, such as communication protocols. For example, the James Webb Space Telescope will use Field Programmable Gate Arrays (FPGAs), which can have over a million logic gates, to send telemetry. System-on-chip (SoC) devices, another type of complex electronics, can combine a microprocessor, input and output channels, and sometimes an FPGA for programmability. With this increased intricacy, the possibility of software-like bugs such as incorrect design, logic, and unexpected interactions within the logic is great. Since CE devices are obscuring the hardware/software boundary, mature software methodologies have been proposed, with slight modifications, to develop these devices. By using standardized S/W Engineering methods such as checklists, missing requirements and bugs can be detected earlier in the development cycle, thus creating a development process for CE that can be easily maintained and configurable based on the device used.
Cryogenic performance of a cryocooler-cooled superconducting undulator
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fuerst, J. D.; Doose, C.; Hasse, Q.
2014-01-29
A cryocooler-cooled superconducting undulator has been installed and operated with beam at the Advanced Photon Source (APS) at Argonne National Laboratory (ANL). The device consists of a dual-core 42-pole magnet structure that is cooled to 4.2 K with a system of four cryocoolers operating in a zero-boil-off configuration. This effort represents the culmination of a development program to establish concept feasibility and evaluate cryostat design and cryocooler-based refrigeration. Cryostat performance is described including cool-down/warm-up, steady-state operation, cooling margin, and the impact of beam during operation in the APS storage ring. Plans for future devices with longer magnets, which will incorporatemore » lessons learned from the development program, are also discussed.« less
ERIC Educational Resources Information Center
Mbogo, Chao; Blake, Edwin; Suleman, Hussein
2014-01-01
The aim of this paper is to explore the use of an application that scaffolds the constructions of programs on a mobile device. The application was developed to support novice learners of programming outside the classroom. This paper reports on results of a first experiment conducted to evaluate the mobile application. The main research questions…
Scaling of Performance in Liquid Propellant Rocket Engine Combustors
NASA Technical Reports Server (NTRS)
Hulka, James R.
2007-01-01
This paper discusses scaling of combustion and combustion performance in liquid propellant rocket engine combustion devices. In development of new combustors, comparisons are often made between predicted performance in a new combustor and measured performance in another combustor with different geometric and thermodynamic characteristics. Without careful interpretation of some key features, the comparison can be misinterpreted and erroneous information used in the design of the new device. This paper provides a review of this performance comparison, including a brief review of the initial liquid rocket scaling research conducted during the 1950s and 1960s, a review of the typical performance losses encountered and how they scale, a description of the typical scaling procedures used in development programs today, and finally a review of several historical development programs to see what insight they can bring to the questions at hand.
Simple solution to the medical instrumentation software problem
NASA Astrophysics Data System (ADS)
Leif, Robert C.; Leif, Suzanne B.; Leif, Stephanie H.; Bingue, E.
1995-04-01
Medical devices now include a substantial software component, which is both difficult and expensive to produce and maintain. Medical software must be developed according to `Good Manufacturing Practices', GMP. Good Manufacturing Practices as specified by the FDA and ISO requires the definition and compliance to a software processes which ensures quality products by specifying a detailed method of software construction. The software process should be based on accepted standards. US Department of Defense software standards and technology can both facilitate the development and improve the quality of medical systems. We describe the advantages of employing Mil-Std-498, Software Development and Documentation, and the Ada programming language. Ada provides the very broad range of functionalities, from embedded real-time to management information systems required by many medical devices. It also includes advanced facilities for object oriented programming and software engineering.
Advanced high temperature static strain sensor development
NASA Technical Reports Server (NTRS)
Hulse, C. O.; Stetson, K. A.; Grant, H. P.; Jameikis, S. M.; Morey, W. W.; Raymondo, P.; Grudkowski, T. W.; Bailey, R. S.
1986-01-01
An examination was made into various techniques to be used to measure static strain in gas turbine liners at temperatures up to 1150 K (1600 F). The methods evaluated included thin film and wire resistive devices, optical fibers, surface acoustic waves, the laser speckle technique with a heterodyne readout, optical surface image and reflective approaches and capacitive devices. A preliminary experimental program to develop a thin film capacitive device was dropped because calculations showed that it would be too sensitive to thermal gradients. In a final evaluation program, the laser speckle technique appeared to work well up to 1150 K when it was used through a relatively stagnant air path. The surface guided acoustic wave approach appeared to be interesting but to require too much development effort for the funds available. Efforts to develop a FeCrAl resistive strain gage system were only partially successful and this part of the effort was finally reduced to a characterization study of the properties of the 25 micron diameter FeCrAl (Kanthal A-1) wire. It was concluded that this particular alloy was not suitable for use as the resistive element in a strain gage above about 1000 K.
Advanced high temperature static strain sensor development
NASA Astrophysics Data System (ADS)
Hulse, C. O.; Stetson, K. A.; Grant, H. P.; Jameikis, S. M.; Morey, W. W.; Raymondo, P.; Grudkowski, T. W.; Bailey, R. S.
1986-08-01
An examination was made into various techniques to be used to measure static strain in gas turbine liners at temperatures up to 1150 K (1600 F). The methods evaluated included thin film and wire resistive devices, optical fibers, surface acoustic waves, the laser speckle technique with a heterodyne readout, optical surface image and reflective approaches and capacitive devices. A preliminary experimental program to develop a thin film capacitive device was dropped because calculations showed that it would be too sensitive to thermal gradients. In a final evaluation program, the laser speckle technique appeared to work well up to 1150 K when it was used through a relatively stagnant air path. The surface guided acoustic wave approach appeared to be interesting but to require too much development effort for the funds available. Efforts to develop a FeCrAl resistive strain gage system were only partially successful and this part of the effort was finally reduced to a characterization study of the properties of the 25 micron diameter FeCrAl (Kanthal A-1) wire. It was concluded that this particular alloy was not suitable for use as the resistive element in a strain gage above about 1000 K.
NREL Photovoltaic Program FY 1995 annual report
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1996-06-01
This report summarizes the in-house and subcontracted R&D activities from Oct. 1994 through Sept. 1995; their objectives are to conduct basic, applied, and engineering research, manage subcontracted R&D projects, perform research complementary to subcontracted work, develop and maintain state-of-the-art measurement and device capabilities, develop PV manufacturing technology and modules, transfer results to industry, and evolve viable partnerships for PV systems and market development. The research activities are grouped into 5 sections: crystalline Si and advanced devices, thin-film PV, PV manufacturing, PV module and system performance and engineering, and PV applications and market development.
A PDA-based electrocardiogram/blood pressure telemonitor for telemedicine.
Bolanos, Marcos; Nazeran, Homayoun; Gonzalez, Izzac; Parra, Ricardo; Martinez, Christopher
2004-01-01
An electrocardiogram (ECG) / blood pressure (BP) telemonitor consisting of comprehensive integration of various electrical engineering concepts, devices, and methods was developed. This personal digital assistant-based (PDAbased) system focused on integration of biopotential amplifiers, photoplethysmographic measurement of blood pressure, microcontroller devices, programming methods, wireless transmission, signal filtering and analysis, interfacing, and long term memory devices (24 hours) to develop a state-of-the-art ECG/BP telemonitor. These instrumentation modules were developed and tested to realize a complete and compact system that could be deployed to assist in telemedicine applications and heart rate variability studies. The specific objective of this device was to facilitate the long term monitoring and recording of ECG and blood pressure signals. This device was able to acquire ECG/BP waveforms, transmit them wirelessly to a PDA, save them onto a compact flash memory, and display them on the LCD screen of the PDA. It was also capable of calculating the heart rate (HR) in beats per minute, and providing systolic and diastolic blood pressure values.
1994-01-01
Disconnect Device for Large HP Permanent Magnet Motors N94-200 Image and Data Management System N94-201 Advanced Lightweight Influence Sweep N94-202 Surf... Permanent Magnet Motors CATEGORY: Exploratory Development SERVICE CRITICAL TECHNOLOGY AREA: Surface/Undersurface Vehicles OBJECTIVE: Design and
NASA Technical Reports Server (NTRS)
1998-01-01
Ratcom, Inc., has joined NASA Johnson Space Center in an active program to develop cytometry capabilities for space station freedom. This agreement results from a cooperative program that NASA entered into with the American Cancer Society to aid in cancer prevention, diagnosis, and treatment. The flow cytometer is used by cancer researchers to make cellular measurements.
Photovoltaic test and demonstration project for the National Photovoltaic Conversion program
NASA Technical Reports Server (NTRS)
Deyo, J. N.
1975-01-01
Proposed are photovoltaic system tests and demonstrations covering a wide range of applications in order to develop low cost photovoltaic cells suitable for terrestrial applications. Program objectives are: (1) tests and model system demonstrations; (2) device performance and diagnostics; and (3) endurance of solar cell modules and arrays.
Computer Service Technician "COMPS." Curriculum Grant 1985.
ERIC Educational Resources Information Center
Schoolcraft Coll., Livonia, MI.
This document is a curriculum guide for a program in computer service technology developed at Schoolcraft College, Livonia, Michigan. The program is designed to give students a strong background in the fundamentals of electricity, electronic devices, and basic circuits (digital and linear). The curriculum includes laboratory demonstrations of the…
LaFollette High School Student Vandalism Committee.
ERIC Educational Resources Information Center
Borland, Glenn F.
The development of an anti-vandalism program based on the principle of an informed student population is described. Volunteer high school and junior high school students operate an educational program for children in the lower grades, using devices such as T-shirts, bumperstickers, lecture presentations and television vignettes. A reward system…
Calculation for simulation of archery goal value using a web camera and ultrasonic sensor
NASA Astrophysics Data System (ADS)
Rusjdi, Darma; Abdurrasyid, Wulandari, Dewi Arianti
2017-08-01
Development of the device simulator digital indoor archery-based embedded systems as a solution to the limitations of the field or open space is adequate, especially in big cities. Development of the device requires simulations to calculate the value of achieving the target based on the approach defined by the parabolic motion variable initial velocity and direction of motion of the arrow reaches the target. The simulator device should be complemented with an initial velocity measuring device using ultrasonic sensors and measuring direction of the target using a digital camera. The methodology uses research and development of application software from modeling and simulation approach. The research objective to create simulation applications calculating the value of the achievement of the target arrows. Benefits as a preliminary stage for the development of the simulator device of archery. Implementation of calculating the value of the target arrows into the application program generates a simulation game of archery that can be used as a reference development of the digital archery simulator in a room with embedded systems using ultrasonic sensors and web cameras. Applications developed with the simulation calculation comparing the outer radius of the circle produced a camera from a distance of three meters.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-11-10
...] Pilot Program for Early Feasibility Study Investigational Device Exemption Applications AGENCY: Food and... feasibility study investigational device exemption (IDE) applications. The pilot program will conform to the... Feasibility Medical Device Clinical Studies, Including Certain First in Human (FIH) Studies.'' Under the pilot...
NASA Technical Reports Server (NTRS)
2014-01-01
On approach, next-generation aircraft are likely to have airframe noise levels that are comparable to or in excess of engine noise. ATA Engineering, Inc. (ATA) is developing a novel quiet engine air brake (EAB), a device that generates "equivalent drag" within the engine through stream thrust reduction by creating a swirling outflow in the turbofan exhaust nozzle. Two Phase II projects were conducted to mature this technology: (1) a concept development program (CDP) and (2) a system development program (SDP).
Digital Screen Media and Cognitive Development.
Anderson, Daniel R; Subrahmanyam, Kaveri
2017-11-01
In this article, we examine the impact of digital screen devices, including television, on cognitive development. Although we know that young infants and toddlers are using touch screen devices, we know little about their comprehension of the content that they encounter on them. In contrast, research suggests that children begin to comprehend child-directed television starting at ∼2 years of age. The cognitive impact of these media depends on the age of the child, the kind of programming (educational programming versus programming produced for adults), the social context of viewing, as well the particular kind of interactive media (eg, computer games). For children <2 years old, television viewing has mostly negative associations, especially for language and executive function. For preschool-aged children, television viewing has been found to have both positive and negative outcomes, and a large body of research suggests that educational television has a positive impact on cognitive development. Beyond the preschool years, children mostly consume entertainment programming, and cognitive outcomes are not well explored in research. The use of computer games as well as educational computer programs can lead to gains in academically relevant content and other cognitive skills. This article concludes by identifying topics and goals for future research and provides recommendations based on current research-based knowledge. Copyright © 2017 by the American Academy of Pediatrics.
Featured Invention: Laser Scaling Device
NASA Technical Reports Server (NTRS)
Dunn, Carol Anne
2008-01-01
In September 2003, NASA signed a nonexclusive license agreement with Armor Forensics, a subsidiary of Armor Holdings, Inc., for the laser scaling device under the Innovative Partnerships Program. Coupled with a measuring program, also developed by NASA, the unit provides crime scene investigators with the ability to shoot photographs at scale without having to physically enter the scene, analyzing details such as bloodspatter patterns and graffiti. This ability keeps the scene's components intact and pristine for the collection of information and evidence. The laser scaling device elegantly solved a pressing problem for NASA's shuttle operations team and also provided industry with a useful tool. For NASA, the laser scaling device is still used to measure divots or damage to the shuttle's external tank and other structures around the launchpad. When the invention also met similar needs within industry, the Innovative Partnerships Program provided information to Armor Forensics for licensing and marketing the laser scaling device. Jeff Kohler, technology transfer agent at Kennedy, added, "We also invited a representative from the FBI's special photography unit to Kennedy to meet with Armor Forensics and the innovator. Eventually the FBI ended up purchasing some units. Armor Forensics is also beginning to receive interest from DoD [Department of Defense] for use in military crime scene investigations overseas."
7 CFR 1463.110 - Misrepresentation and scheme or device.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 7 Agriculture 10 2012-01-01 2012-01-01 false Misrepresentation and scheme or device. 1463.110... PROGRAM Tobacco Transition Payment Program § 1463.110 Misrepresentation and scheme or device. A person... program determination made in accordance with this subpart; (b) Adopted any scheme or device that tends to...
7 CFR 1463.110 - Misrepresentation and scheme or device.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 7 Agriculture 10 2011-01-01 2011-01-01 false Misrepresentation and scheme or device. 1463.110... PROGRAM Tobacco Transition Payment Program § 1463.110 Misrepresentation and scheme or device. A person... program determination made in accordance with this subpart; (b) Adopted any scheme or device that tends to...
7 CFR 1463.110 - Misrepresentation and scheme or device.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 7 Agriculture 10 2014-01-01 2014-01-01 false Misrepresentation and scheme or device. 1463.110... PROGRAM Tobacco Transition Payment Program § 1463.110 Misrepresentation and scheme or device. A person... program determination made in accordance with this subpart; (b) Adopted any scheme or device that tends to...
7 CFR 1463.110 - Misrepresentation and scheme or device.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 7 Agriculture 10 2013-01-01 2013-01-01 false Misrepresentation and scheme or device. 1463.110... PROGRAM Tobacco Transition Payment Program § 1463.110 Misrepresentation and scheme or device. A person... program determination made in accordance with this subpart; (b) Adopted any scheme or device that tends to...
7 CFR 1463.110 - Misrepresentation and scheme or device.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 10 2010-01-01 2010-01-01 false Misrepresentation and scheme or device. 1463.110... PROGRAM Tobacco Transition Payment Program § 1463.110 Misrepresentation and scheme or device. A person... program determination made in accordance with this subpart; (b) Adopted any scheme or device that tends to...
Research and Development Strategies in the Semiconductor Industry
NASA Astrophysics Data System (ADS)
Bowling, Allen
2003-03-01
In the 21st Century semiconductor industry, there is a critical balance between internally funded semiconductor research and development (R) and externally funded R. External R may include jointly-funded research collaborations/partnerships with other device manufacturers, jointly-funded consortia-based R, and individually-funded research programs at universities and other contract research locations. Each of these approaches has merits and each has costs. There is a critical balance between keeping the internal research and development pipeline filled and keeping it from being overspent. To meet both competitive schedule and cost goals, a semiconductor device manufacturer must decide on a model for selection of internal versus external R. Today, one of the most critical decisions is whether or not to do semiconductor research and development on 300 mm silicon wafers. Equipment suppliers are doing first development on 300 mm equipment. So, for the device manufacturer, there is a balance between the cost of doing development on 300 mm wafers and the development time schedule driven by equipment availability. In the face of these cost and schedule elements, device manufacturers are looking to consortia such as SEMATECH, SRC, and SRC MARCO for early development and screening of new materials and device structure approaches. This also causes much more close development collaboration between device manufacturer and equipment supplier. Many device manufacturers are also making use of direct contract research with universities and other contract-research organizations, such as IMEC, LETI, and other government-funded research organizations around the world. To get the most out of these external research interactions, the company must develop a strategy for management and technology integration of external R.
An Assessment of Pathology Resident Access to and Use of Technology: A Nationwide Survey.
Vallangeon, Bethany D; Hawley, Jeffrey S; Sloane, Richard; Bean, Sarah M
2017-03-01
- Current technologies including digital slide scanners and handheld devices can revolutionize clinical practice and pathology graduate medical education (GME). The extent to which these technologies are used in pathology GME is unknown. - To determine the types of technologies used, usage amount, and how they are integrated into pathology residency/fellowship programs nationwide. - A 40-question online survey for residents/fellows was developed and administered via the Research Electronic Data Capture System after institutional review board approval. - Fifty-two program directors (37%) gave permission for participation. One-hundred seventy-one responses were received (18% response rate). Most respondents have access to personal technology (laptop = 78% [134 of 171]), smartphone = 81% [139 of 171], tablet = 49% [84 of 171]), and Web-based digital slide collections (82%, 141 of 171). Few residents are provided electronic devices by their programs (laptop = 22% [38 of 171], smartphone = 0.5% [1 of 171], and tablet = 12% [21 of 171]). Fifty-nine percent have access to digital slide scanners, 33% have access to a program-created database of digitized slides, and 52% use telepathology. Fifteen percent have access to asynchronous learning. Of those with access to video-recorded conferences, 89% review them. Program size was significantly positively correlated with resident access to program-provided laptops (P = .02) and tablets (P < .001), digital slide scanners (P = .01), and telepathology (P = .001). Of all devices, program-provided laptops are used most for professional work (60.5% use this device for more than 5 hours per day). - Most residents report access to multiple types of innovative technology, but incorporation of these tools within pathology training programs is highly variable. Opportunities for incorporating innovative technologies exist and could be further explored.
Flexible devices: from materials, architectures to applications
NASA Astrophysics Data System (ADS)
Zou, Mingzhi; Ma, Yue; Yuan, Xin; Hu, Yi; Liu, Jie; Jin, Zhong
2018-01-01
Flexible devices, such as flexible electronic devices and flexible energy storage devices, have attracted a significant amount of attention in recent years for their potential applications in modern human lives. The development of flexible devices is moving forward rapidly, as the innovation of methods and manufacturing processes has greatly encouraged the research of flexible devices. This review focuses on advanced materials, architecture designs and abundant applications of flexible devices, and discusses the problems and challenges in current situations of flexible devices. We summarize the discovery of novel materials and the design of new architectures for improving the performance of flexible devices. Finally, we introduce the applications of flexible devices as key components in real life. Project supported by the National Key R&D Program of China (Nos. 2017YFA0208200, 2016YFB0700600, 2015CB659300), the National Natural Science Foundation of China (Nos. 21403105, 21573108), and the Fundamental Research Funds for the Central Universities (No. 020514380107).
ERIC Educational Resources Information Center
WHITE, HARVEY E.
THIS IS AN OUTLINE OF PROCEDURES FOLLOWED IN DEVELOPING EXHIBITS SUITABLE AS AUTOINSTRUCTIONAL DEVICES AND AS DEMONSTRATION DEVICES FOR EDUCATIONAL TELEVISION PROGRAMS. THE 27 TEACHING EXHIBITS WERE DESIGNED TO HELP STUDENTS UNDERSTAND CONCEPTS AND PERFORM EXPERIMENTS IN PHYSICS, MATHEMATICS, CHEMISTRY, AND BIOLOGY. SOME OF THE EXHIBITS EMPLOYED…
The Defense Threat Reduction Agency's Technical Nuclear Forensics Research and Development Program
NASA Astrophysics Data System (ADS)
Franks, J.
2015-12-01
The Defense Threat Reduction Agency (DTRA) Technical Nuclear Forensics (TNF) Research and Development (R&D) Program's overarching goal is to design, develop, demonstrate, and transition advanced technologies and methodologies that improve the interagency operational capability to provide forensics conclusions after the detonation of a nuclear device. This goal is attained through the execution of three focus areas covering the span of the TNF process to enable strategic decision-making (attribution): Nuclear Forensic Materials Exploitation - Development of targeted technologies, methodologies and tools enabling the timely collection, analysis and interpretation of detonation materials.Prompt Nuclear Effects Exploitation - Improve ground-based capabilities to collect prompt nuclear device outputs and effects data for rapid, complementary and corroborative information.Nuclear Forensics Device Characterization - Development of a validated and verified capability to reverse model a nuclear device with high confidence from observables (e.g., prompt diagnostics, sample analysis, etc.) seen after an attack. This presentation will outline DTRA's TNF R&D strategy and current investments, with efforts focusing on: (1) introducing new technical data collection capabilities (e.g., ground-based prompt diagnostics sensor systems; innovative debris collection and analysis); (2) developing new TNF process paradigms and concepts of operations to decrease timelines and uncertainties, and increase results confidence; (3) enhanced validation and verification (V&V) of capabilities through technology evaluations and demonstrations; and (4) updated weapon output predictions to account for the modern threat environment. A key challenge to expanding these efforts to a global capability is the need for increased post-detonation TNF international cooperation, collaboration and peer reviews.
Mod-0A Wind Turbine in Block Island, Rhode Island
1979-06-21
A Mod-0A 200-kilowatt wind turbine designed by National Aeronautics and Space Administration (NASA) Lewis Research Center and constructed in Block Island, Rhode Island. The wind turbine program was a joint program between NASA and the Energy Research and Development Administration (ERDA) during the 1970s to develop less expensive forms of energy. NASA Lewis was assigned the responsibility of developing large horizontal-axis wind turbines. The program included a series of increasingly powerful wind turbines, designated: Mod-0A, Mod-1, WTS-4, and Mod-5. The program’s first device was a Mod-0 100-kilowatt wind turbine test bed at NASA’s Plum Brook Station. This Mod-0A 200-kilowatt turbine, completed in 1977, was the program’s second-generation device. It included a 125-foot diameter blade atop a 100-foot tall tower. This early wind turbine was designed determine its operating problems, integrate with the local utilities, and assess the attitude of the local community. There were additional Mod-0A turbines built in Culebra, Puerto Rico; Clayton, New Mexico; and Oahu, Hawaii. The Mod-0A turbines suffered durability issues with the rotor blade and initially appeared unreliable. NASA engineers addressed the problems, and the turbines proved to be reliable and efficient devices that operated for a number of years. The information gained from these early models was vital to the design and improvement of the later generations.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Birkmire, R.W.; Phillips, J.E.; Shafarman, W.N.
2000-08-25
This report describes results achieved during phase 1 of a three-phase subcontract to develop and understand thin-film solar cell technology associated to CuInSe{sub 2} and related alloys, a-Si and its alloys, and CdTe. Modules based on all these thin films are promising candidates to meet DOE long-range efficiency, reliability, and manufacturing cost goals. The critical issues being addressed under this program are intended to provide the science and engineering basis for the development of viable commercial processes and to improve module performance. The generic research issues addressed are: (1) quantitative analysis of processing steps to provide information for efficient commercial-scalemore » equipment design and operation; (2) device characterization relating the device performance to materials properties and process conditions; (3) development of alloy materials with different bandgaps to allow improved device structures for stability and compatibility with module design; (4) development of improved window/heterojunction layers and contacts to improve device performance and reliability; and (5) evaluation of cell stability with respect to illumination, temperature, and ambient and with respect to device structure and module encapsulation.« less
Development and content validation of the power mobility training tool.
Kenyon, Lisa K; Farris, John P; Cain, Brett; King, Emily; VandenBerg, Ashley
2018-01-01
This paper outlines the development and content validation of the power mobility training tool (PMTT), an observational tool designed to assist therapists in developing power mobility training programs for children who have multiple, severe impairments. Initial items on the PMTT were developed based on a literature review and in consultation with therapists experienced in the use of power mobility. Items were trialled in clinical settings, reviewed, and refined. Items were then operationalized and an administration manual detailing scoring for each item was created. Qualitative and quantitative methods were used to establish content validity via a 15 member, international expert panel. The content validity ratio (CVR) was determined for each possible item. Of the 19 original items, 10 achieved minimum required CVR values and were included in the final version of the PMTT. Items related to manoeuvring a power mobility device were merged and an item related to the number of switches used concurrently to operate a power mobility device were added to the PMTT. The PMTT may assist therapists in developing training programs that facilitate the acquisition of beginning power mobility skills in children who have multiple, severe impairments. Implications for Rehabilitation The Power Mobility Training Tool (PMTT) was developed to help guide the development of power mobility intervention programs for children who have multiple, severe impairments. The PMTT can be used with children who access a power mobility device using either a joystick or a switch. Therapists who have limited experience with power mobility may find the PMTT to be helpful in setting up and conducting power mobility training interventions as a feasible aspect of a plan of care for children who have multiple, severe impairments.
Virtual Frame Buffer Interface Program
NASA Technical Reports Server (NTRS)
Wolfe, Thomas L.
1990-01-01
Virtual Frame Buffer Interface program makes all frame buffers appear as generic frame buffer with specified set of characteristics, allowing programmers to write codes that run unmodified on all supported hardware. Converts generic commands to actual device commands. Consists of definition of capabilities and FORTRAN subroutines called by application programs. Developed in FORTRAN 77 for DEC VAX 11/780 or DEC VAX 11/750 computer under VMS 4.X.
NREL Photovoltaic Program. FY 1994 annual report, October 1, 1993--September 30, 1994
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1995-06-01
This report summarizes the in-house and subcontracted research and development activities under the National renewable Energy Laboratory (NREL) Photovoltaics (PV) program for fiscal year 1994. Research is organized under the following areas; PV program management; crystalline silicon and advanced devices; thin-film PV technologies; PV manufacturing; PV module and system performance and engineering; and PV applications and markets.
Software Process Assurance for Complex Electronics (SPACE)
NASA Technical Reports Server (NTRS)
Plastow, Richard A.
2007-01-01
Complex Electronics (CE) are now programmed to perform tasks that were previously handled in software, such as communication protocols. Many of the methods used to develop software bare a close resemblance to CE development. For instance, Field Programmable Gate Arrays (FPGAs) can have over a million logic gates while system-on-chip (SOC) devices can combine a microprocessor, input and output channels, and sometimes an FPGA for programmability. With this increased intricacy, the possibility of software-like bugs such as incorrect design, logic, and unexpected interactions within the logic is great. Since CE devices are obscuring the hardware/software boundary, we propose that mature software methodologies may be utilized with slight modifications in the development of these devices. Software Process Assurance for Complex Electronics (SPACE) is a research project that looks at using standardized S/W Assurance/Engineering practices to provide an assurance framework for development activities. Tools such as checklists, best practices and techniques can be used to detect missing requirements and bugs earlier in the development cycle creating a development process for CE that will be more easily maintained, consistent and configurable based on the device used.
78 FR 77209 - Accessibility of User Interfaces, and Video Programming Guides and Menus
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-20
... user interfaces on digital apparatus and video programming guides and menus on navigation devices for... apparatus and navigation devices used to view video programming. The rules we adopt here will effectuate...--that is, devices and other equipment used by consumers to access multichannel video programming and...
Further Development of a Robotic-Assisted Transfer Device
Burkman, Jessica; Grindle, Garrett; Wang, Hongwu; Kelleher, Annmarie
2017-01-01
Background: The task of performing transfers, such as from a wheelchair to a bed, has a high risk of injury to both the caregiver and the person being transferred. Although mechanical transfer devices can reduce these risks, these devices are not meant for use in the community and they still place strain on the caregiver when used. Purpose: The aim of this study is to describe feedback gathered from focus groups of potential users of the Robotic-Assisted Transfer Device (RATD) and describe design changes aimed at preparing the device for the next step in the development process. Method: The RATD was transferred to a newer electric-powered wheelchair (EPW), key components were redesigned, and the control program was updated to increase the safety of the device. Two focus groups, one consisting of people with disabilities and the other consisting of clinicians and caregivers, were conducted to gather feedback from potential users. Results: Error checking, safety zones, a motor brake, and a new track helped increase the safety of the device. Sixty-three percent of the people with disabilities and 83% of caregivers surveyed said they would use the device. Conclusions: The results from the focus groups were positive and the design changes were successful, but more development is needed before the RATD can be marketed. PMID:29339890
1982-02-25
source both liquid and solid fuel combustion devices have been successfully demonstrated during various development programs . Nuclear reactor heat...U02 fuel in the core . Improving the heat pipe model to correlate more closely with the experimental data is a major concern in the development of...ORGANIZATION NAME AND ADDRESS 10. PROGRAM ELEMENT, PROJECT. TASK Research & Development Associates (RDA) AREA &WKNT AE (X Rosslyn, VA 22209 61102F 2301
Development of a CCD based solar speckle imaging system
NASA Astrophysics Data System (ADS)
Nisenson, Peter; Stachnik, Robert V.; Noyes, Robert W.
1986-02-01
A program to develop software and hardware for the purpose of obtaining high angular resolution images of the solar surface is described. The program included the procurement of a Charge Coupled Devices imaging system; an extensive laboratory and remote site testing of the camera system; the development of a software package for speckle image reconstruction which was eventually installed and tested at the Sacramento Peak Observatory; and experiments of the CCD system (coupled to an image intensifier) for low light level, narrow spectral band solar imaging.
The Wake Shield Facility: A space experiment platform
NASA Technical Reports Server (NTRS)
Allen, Joseph P.
1991-01-01
Information is given in viewgraph form on Wakeshield, a space experiment platform. The Wake Shield Facility (WSF) flight program objectives, product applications, commercial development approach, and cooperative experiments are listed. The program objectives are to produce new industry-driven electronic, magnetic, and superconducting thin-film materials and devices both in terrestrial laboratories and in space; utilize the ultra-vacuum of space for thin film epitaxial growth and materials processing; and develop commercial space hardware for research and development and enhanced access to space.
Ag2S atomic switch-based `tug of war' for decision making
NASA Astrophysics Data System (ADS)
Lutz, C.; Hasegawa, T.; Chikyow, T.
2016-07-01
For a computing process such as making a decision, a software controlled chip of several transistors is necessary. Inspired by how a single cell amoeba decides its movements, the theoretical `tug of war' computing model was proposed but not yet implemented in an analogue device suitable for integrated circuits. Based on this model, we now developed a new electronic element for decision making processes, which will have no need for prior programming. The devices are based on the growth and shrinkage of Ag filaments in α-Ag2+δS gap-type atomic switches. Here we present the adapted device design and the new materials. We demonstrate the basic `tug of war' operation by IV-measurements and Scanning Electron Microscopy (SEM) observation. These devices could be the base for a CMOS-free new computer architecture.For a computing process such as making a decision, a software controlled chip of several transistors is necessary. Inspired by how a single cell amoeba decides its movements, the theoretical `tug of war' computing model was proposed but not yet implemented in an analogue device suitable for integrated circuits. Based on this model, we now developed a new electronic element for decision making processes, which will have no need for prior programming. The devices are based on the growth and shrinkage of Ag filaments in α-Ag2+δS gap-type atomic switches. Here we present the adapted device design and the new materials. We demonstrate the basic `tug of war' operation by IV-measurements and Scanning Electron Microscopy (SEM) observation. These devices could be the base for a CMOS-free new computer architecture. Electronic supplementary information (ESI) available. See DOI: 10.1039/c6nr00690f
Development of Urine Receptacle Assembly for the Crew Exploration Vehicle
NASA Technical Reports Server (NTRS)
Cibuzar, Branelle Rae; Thomas, Evan; Peterson, Laurie; Goforth, Johanna
2008-01-01
The Urine Receptacle Assembly (URA) initially was developed for Apollo as a primary means of urine collection. The aluminum housing with stainless steel honeycomb insert provided all male crewmembers with a non-invasive means of micturating into a urine capturing device and then venting to space. The performance of the URA was a substantial improvement over previous devices but its performance was not well understood. The Crew Exploration Vehicle (CEV) program is exploring the URA as a contingency liquid waste management system for the vehicle. URA improvements are required to meet CEV requirements, including: consumables minimization, flow performance, acceptable hygiene standards, crew comfort, and female crewmember capability. This paper presents the results of a historical review of URA performance during the Apollo program, recent URA performance tests on the reduced gravity aircraft flight under varying flow conditions, and a proposed development plan for the URA to meet CEV needs.
Embedded Thermal Control for Spacecraft Subsystems Miniaturization
NASA Technical Reports Server (NTRS)
Didion, Jeffrey R.
2014-01-01
Optimization of spacecraft size, weight and power (SWaP) resources is an explicit technical priority at Goddard Space Flight Center. Embedded Thermal Control Subsystems are a promising technology with many cross cutting NSAA, DoD and commercial applications: 1.) CubeSatSmallSat spacecraft architecture, 2.) high performance computing, 3.) On-board spacecraft electronics, 4.) Power electronics and RF arrays. The Embedded Thermal Control Subsystem technology development efforts focus on component, board and enclosure level devices that will ultimately include intelligent capabilities. The presentation will discuss electric, capillary and hybrid based hardware research and development efforts at Goddard Space Flight Center. The Embedded Thermal Control Subsystem development program consists of interrelated sub-initiatives, e.g., chip component level thermal control devices, self-sensing thermal management, advanced manufactured structures. This presentation includes technical status and progress on each of these investigations. Future sub-initiatives, technical milestones and program goals will be presented.
NASA Astrophysics Data System (ADS)
Hendikawati, P.; Arifudin, R.; Zahid, M. Z.
2018-03-01
This study aims to design an android Statistics Data Analysis application that can be accessed through mobile devices to making it easier for users to access. The Statistics Data Analysis application includes various topics of basic statistical along with a parametric statistics data analysis application. The output of this application system is parametric statistics data analysis that can be used for students, lecturers, and users who need the results of statistical calculations quickly and easily understood. Android application development is created using Java programming language. The server programming language uses PHP with the Code Igniter framework, and the database used MySQL. The system development methodology used is the Waterfall methodology with the stages of analysis, design, coding, testing, and implementation and system maintenance. This statistical data analysis application is expected to support statistical lecturing activities and make students easier to understand the statistical analysis of mobile devices.
NASA Astrophysics Data System (ADS)
Shinozaki, Kenichi; Yanaru, Torao
Recently, IT (Information Technology) have rapidly revolved and penetrated into the usual human life, with such as the household appliances and the mobile devices. Considering this strong change of social environment, what technology is introduced to satisfy the present educational needs and how to develop the teaching system is very important. Then in this paper, we describe the developed web-teaching material that links Xport, an embedded device server, with the control system using microcontroller technology. In the classes, we have implemented the lessons that utilize this system in the following subjects : programming technology, hardware technology, electronic circuit and practical training. Furthermore, because of high availability of the developed system through internet, it is also useful for the education on science and technical arts in general high schools or in junior high schools as well as in technical high schools.
Medical Device Plug-and-Play (MD PnP) Interoperability Standardization Program Development
2009-08-01
TATRC / DoD Sandy Weininger, FDA / CDRH ICE-PAC / Industry Tracy Rausch, DocBox Inc. Ken Fuchs, Draeger Medical Carl Wallroth, Draeger Medical...Systems (LSTAT) Paul Jones, FDA / CDRH Kamran Sayrafian-Pour, NIST © 2006-2009 a white paper from the MD PnP Program rev July 2009 Advancing
Enhancing the Use of Vehicle Alcohol Interlocks With Emerging Technology.
Voas, Robert B
2014-01-01
Among the earliest applications of health technologies to a safety program was the development of blood alcohol content (BAC) tests for use in impaired-driving enforcement. This led to the development of miniature, highly accurate devices that officers could carry in their pockets. A natural extension of this technology was the vehicle alcohol interlock, which is used to reduce recidivism among drivers convicted of driving under the influence (DUI) by requiring them to install the devices (which will not allow someone with a positive BAC to drive) on their vehicles. While on the vehicle, interlocks have been shown to reduce recidivism by two-thirds. Use of these devices has been growing at the rate of 10 to 15 percent a year, and there currently are more than 300,000 units in use. This expansion in the application of interlocks has benefited from the integration of other emerging technologies into interlock systems. Such technologies include data systems that record both driver actions and vehicle responses, miniature cameras and face recognition to identify the user, Wi-Fi systems to provide rapid reporting on offender performance and any attempt to circumvent the device, GPS tracking of the vehicle, and more rapid means for monitoring the integrity of the interlock system. This article describes how these health technologies are being applied in interlock programs and the outlook for new technologies and new court sanctioning programs that may influence the growth in the use of interlocks in the future.
SuperState: a computer program for the control of operant behavioral experimentation.
Zhang, Fuqiang
2006-09-15
Operant behavioral researches require precise control of experimental devices for delivering stimuli and monitoring behavioral responses. The author developed a software solution named SuperState for controlling hardware devices and running reinforcement schedules. The Microsoft Windows compatible software was written by use of an object-oriented programming language Borland Delphi 5.0, which has simplified the programming of the application. SuperState is a stand-alone easy-to-use green software, without the need for the experimenter to master any scripting languages. It features: (1) control of multiple operant cages running independent reinforcement schedules; (2) enough cage devices (16 digital inputs and 16 digital outputs for each cage) suitable for the need of most operant behavioral equipments; (3) control of most standard ISA-type digital interface cards including Med-Associates Super-port cards and a PCI-type card AC6412, and highly expandable to support other PCI-type interface cards; (4) high-resolution device control (1ms); (5) a built-in real-time cumulative recorder; (6) extensive data analyzing including event recorder, cumulative recorder, block analyzing; the summarized results can be transferred easily to Microsoft Excel spreadsheets through the Clipboard.
The Tufts Non-Vocal Communication Program.
ERIC Educational Resources Information Center
Foulds, Richard A.; And Others
Described are the efforts of the Biomedical Engineering Center in developing devices, particularly the Tufts Interactive Communicator (TIC) for the non-vocal severely physically disabled individual. It is noted that research has been conducted in the following areas: dictionary development, anticipatory communication, symbol communication, symbol…
Point-of-Care Programming for Neuromodulation: A Feasibility Study Using Remote Presence.
Mendez, Ivar; Song, Michael; Chiasson, Paula; Bustamante, Luis
2013-01-01
The expansion of neuromodulation and its indications has resulted in hundreds of thousands of patients with implanted devices worldwide. Because all patients require programming, this growth has created a heavy burden on neuromodulation centers and patients. Remote point-of-care programming may provide patients with real-time access to neuromodulation expertise in their communities. To test the feasibility of remotely programming a neuromodulation device using a remote-presence robot and to determine the ability of an expert programmer to telementor a nonexpert in programming the device. A remote-presence robot (RP-7) was used for remote programming. Twenty patients were randomly assigned to either conventional programming or a robotic session. The expert remotely mentored 10 nurses with no previous experience to program the devices of patients assigned to the remote-presence sessions. Accuracy of programming, adverse events, and satisfaction scores for all participants were assessed. There was no difference in the accuracy or clinical outcomes of programming between the standard and remote-presence sessions. No adverse events occurred in any session. The patients, nurses, and the expert programmer expressed high satisfaction scores with the remote-presence sessions. This study establishes the proof-of-principle that remote programming of neuromodulation devices using telepresence and expert telementoring of an individual with no previous experience to accurately program a device is feasible. We envision a time in the future when patients with implanted devices will have real-time access to neuromodulation expertise from the comfort of their own home.
Advanced electrical power system technology for the all electric aircraft
NASA Technical Reports Server (NTRS)
Finke, R. C.; Sundberg, G. R.
1983-01-01
The application of advanced electric power system technology to an all electric airplane results in an estimated reduction of the total takeoff gross weight of over 23,000 pounds for a large airplane. This will result in a 5 to 10 percent reduction in direct operating costs (DOC). Critical to this savings is the basic electrical power system component technology. These advanced electrical power components will provide a solid foundation for the materials, devices, circuits, and subsystems needed to satisfy the unique requirements of advanced all electric aircraft power systems. The program for the development of advanced electrical power component technology is described. The program is divided into five generic areas: semiconductor devices (transistors, thyristors, and diodes); conductors (materials and transmission lines); dielectrics; magnetic devices; and load management devices. Examples of progress in each of the five areas are discussed. Bipolar power transistors up to 1000 V at 100 A with a gain of 10 and a 0.5 microsec rise and fall time are presented. A class of semiconductor devices with a possibility of switching up to 100 kV is described. Solid state power controllers for load management at 120 to 1000 V and power levels to 25 kW were developed along with a 25 kW, 20 kHz transformer weighing only 3.2 kg. Previously announced in STAR as N83-24764
Daylight control system device and method
Paton, John Douglas
2007-03-13
A system and device for and a method of programming and controlling light fixtures is disclosed. A system in accordance with the present invention includes a stationary controller unit that is electrically coupled to the light fixtures. The stationary controller unit is configured to be remotely programmed with a portable commissioning device to automatically control the lights fixtures. The stationary controller unit and the portable commissioning device include light sensors, micro-computers and transceivers for measuring light levels, running programs, storing data and transmitting data between the stationary controller unit and the portable commissioning device. In operation, target light levels selected with the portable commissioning device and the controller unit is remotely programmed to automatically maintain the target level.
Daylight control system, device and method
Paton, John Douglas
2012-08-28
A system and device for and a method of programming and controlling light fixtures is disclosed. A system in accordance with the present invention includes a stationary controller unit that is electrically coupled to the light fixtures. The stationary controller unit is configured to be remotely programmed with a portable commissioning device to automatically control the lights fixtures. The stationary controller unit and the portable commissioning device include light sensors, micro-computers and transceivers for measuring light levels, running programs, storing data and transmitting data between the stationary controller unit and the portable commissioning device. In operation, target light levels selected with the portable commissioning device and the controller unit is remotely programmed to automatically maintain the target level.
Daylight control system device and method
Paton, John Douglas
2009-12-01
A system and device for and a method of programming and controlling light fixtures is disclosed. A system in accordance with the present invention includes a stationary controller unit that is electrically coupled to the light fixtures. The stationary controller unit is configured to be remotely programmed with a portable commissioning device to automatically control the lights fixtures. The stationary controller unit and the portable commissioning device include light sensors, micro-computers and transceivers for measuring light levels, running programs, storing data and transmitting data between the stationary controller unit and the portable commissioning device. In operation, target light levels selected with the portable commissioning device and the controller unit is remotely programmed to automatically maintain the target level.
Fabrication techniques and applications of flexible graphene-based electronic devices
NASA Astrophysics Data System (ADS)
Luqi, Tao; Danyang, Wang; Song, Jiang; Ying, Liu; Qianyi, Xie; He, Tian; Ningqin, Deng; Xuefeng, Wang; Yi, Yang; Tian-Ling, Ren
2016-04-01
In recent years, flexible electronic devices have become a hot topic of scientific research. These flexible devices are the basis of flexible circuits, flexible batteries, flexible displays and electronic skins. Graphene-based materials are very promising for flexible electronic devices, due to their high mobility, high elasticity, a tunable band gap, quantum electronic transport and high mechanical strength. In this article, we review the recent progress of the fabrication process and the applications of graphene-based electronic devices, including thermal acoustic devices, thermal rectifiers, graphene-based nanogenerators, pressure sensors and graphene-based light-emitting diodes. In summary, although there are still a lot of challenges needing to be solved, graphene-based materials are very promising for various flexible device applications in the future. Project supported by the National Natural Science Foundation of China (Nos. 60936002, 61025021, 61434001, 61574083), the State Key Development Program for Basic Research of China (No. 2015CB352100), the National Key Project of Science and Technology (No. 2011ZX02403-002) and the Special Fund for Agroscientific Research in the Public Interest of China (No. 201303107). M.A.M is additionally supported by the Postdoctoral Fellowship (PDF) Program of the Natural Sciences and Engineering Research Council (NSERC) of Canada and China's Postdoctoral Science Foundation (CPSF).
Mobilizing the GLOBE at Night Citizen-Scientist
NASA Astrophysics Data System (ADS)
Newhouse, M. A.; Walker, C. E.; Boss, S. K.; Hennig, A. J.
2012-12-01
GLOBE at Night is an international campaign to raise public awareness of the impact of light pollution. Citizen-scientists around the world measure their night sky brightness and submit their observations to a website from a computer. In the last two years a web application (webapp) was developed to enable reporting from mobile devices. Nearly 80,000 data points have been submitted by people in 115 countries during the last 7 years. Our poster will examine the effect of enabling real-time data reporting via mobile devices, and how the Adopt-a-Street pilot project has impacted data collection in two U.S. cities. Recognizing the increasing popularity of smartphones, in late 2010 NOAO staff built a webapp to take advantage of the GPS capabilities built into mobile devices to get an automated and accurate report of the user's location. Refinements to the application have enabled an order of magnitude reduction in the number of erroneous data points due to incorrect location. During the 2011 campaign a pilot program called Adopt-a-Street was created to further take advantage of the ability to report data in real-time via mobile devices. For the 2012 campaign the program continued in Tucson and expanded to Fayetteville, Arkansas. Both of these sub-campaigns encouraged more participation, and resulted in more meaningful results. For example, in prior years Fayetteville averaged three data points in the three years any points were submitted in that area. In 2012, due to the Adopt-a-Street program, there were 98 points submitted, clearly matching the map on their Adopt-a-Street page. Adding support for mobile devices has increased the accuracy and relevance of the data submitted via both mobile devices and desktop computers, as well as enabled new programs. We plan to expand the Adopt-a-Street program next year and find an easier way to accommodate multiple measurements.
Mobilizing the GLOBE at Night Citizen-Scientist
NASA Astrophysics Data System (ADS)
Newhouse, M. A.; Walker, C. E.; Boss, S. K.; Hennig, A. J.
2013-04-01
GLOBE at Night is an international campaign to raise public awareness of the impact of light pollution. Citizen-scientists around the world measure their night sky brightness and submit their observations to a website from a computer. In the last two years a webapp was developed to enable reporting from mobile devices. Nearly 80,000 data points have been submitted by people in 115 countries during the last 7 years. Our poster will examine the effect of enabling real-time data reporting via mobile devices, and how the Adopt-a-Street pilot project has impacted data collection in two U.S. cities. Recognizing the increasing popularity of smartphones, in late 2010 NOAO staff built a webapp to take advantage of the GPS capabilities built into mobile devices to get an automated and accurate report of the user's location. Refinements to the application have enabled an order of magnitude reduction in the number of erroneous data points due to incorrect location. During the 2011 campaign a pilot program called Adopt-a-Street was created to further take advantage of the ability to report data in real-time via mobile devices. For the 2012 campaign the program continued in Tucson and expanded to Fayetteville, Arkansas. Both of these sub-campaigns encouraged more participation, and resulted in more meaningful results. For example, in prior years Fayetteville averaged three data points in the three years any points were submitted in that area. In 2012, due to the Adopt-a-Street program, there were 98 points submitted, clearly matching the map on their Adopt-a-Street page. Adding support for mobile devices has increased the accuracy and relevance of the data submitted via both mobile devices and desktop computers, as well as enabled new programs. We plan to expand the Adopt-a-Street program next year and find an easier way to accommodate multiple measurements.
Baseline experimental investigation of an electrohydrodynamically assisted heat pipe
NASA Technical Reports Server (NTRS)
Duncan, A. B.
1995-01-01
The increases in power demand and associated thermal management requirements of future space programs such as potential Lunar/Mars missions will require enhancing the operating efficiencies of thermal management devices. Currently, the use of electrohydrodynamically (EHD) assisted thermal control devices is under consideration as a potential method of increasing thermal management system capacity. The objectives of the currently described investigation included completing build-up of the EHD-Assisted Heat Pipe Test bed, developing test procedures for an experimental evaluation of the unassisted heat pipe, developing an analytical model capable of predicting the performance limits of the unassisted heat pipe, and obtaining experimental data which would define the performance characteristics of the unassisted heat pipe. The information obtained in the currently proposed study will be used in order to provide extensive comparisons with the EHD-assisted performance observations to be obtained during the continuing investigation of EHD-Assisted heat transfer devices. Through comparisons of the baseline test bed data and the EHD assisted test bed data, accurate insight into the performance enhancing characteristics of EHD augmentation may be obtained. This may lead to optimization, development, and implementation of EHD technology for future space programs.
Hanafusa, A; Komeda, T; Ito, K; Zobel, P Beomonte
2015-08-01
Project-based learning (PBL) is effective for developing human resources of young students. The design of welfare equipment, such as wheelchairs and gait assistive devices, is taken as the subject in this study because these devices must be fit to their environment, users, and method of use; students must consider the circumstances of each country concerned. The program commenced in 2012 at L'Aquila, Italy, and the Shibaura Institute of Technology, Japan and has been continuing for three years. Students were divided into four groups and discussions were held on how to adapt the equipment to the user and environment. After discussion, they designed and simulated a model of the equipment using CAD. Finally, they presented their designs to each other. Through the program, students had fruitful discussions, exchanged ideas from different cultures, and learned from each other. Furthermore, friendships among the students were nurtured. It is believed that the objective of the program was satisfactorily accomplished.
New technology in electrophysiology: FDA process and perspective.
Selzman, Kimberly A; Fellman, Mark; Farb, Andrew; de Del Castillo, Sergio; Zuckerman, Bram
2016-10-01
The Food and Drug Administration (FDA) is a large regulatory agency that monitors everything from food, tobacco, and veterinary medicine to pharmaceutical drugs and medical devices. The Mission statement of the CDRH, one of the Centers of the FDA, in its most succinct form is to protect and promote public health. This is accomplished through timely and continued access to safe, effective, and high quality medical devices. This paper aims to review the overarching principles of the Agency's review process for cardiac devices as well as highlight some of the newer programs that FDA has engaged in to facilitate innovation, device development, research, and timely market approval.
Power components for the Space Station 20-kHz power distribution system
NASA Technical Reports Server (NTRS)
Renz, David D.
1988-01-01
Since 1984, NASA Lewis Research Center was developing high power, high frequency space power components as part of The Space Station Advanced Development program. The purpose of the Advanced Development program was to accelerate existing component programs to ensure their availability for use on the Space Station. These components include a rotary power transfer device, remote power controllers, remote bus isolators, high power semiconductor, a high power semiconductor package, high frequency-high power cable, high frequency-high power connectors, and high frequency-high power transformers. All the components were developed to the prototype level and will be installed in the Lewis Research Center Space Station power system test bed.
Power components for the space station 20-kHz power distribution system
NASA Technical Reports Server (NTRS)
Renz, David D.
1988-01-01
Since 1984, NASA Lewis Research Center was developing high power, high frequency space power components as part of The Space Station Advanced Development program. The purpose of The Advanced Development program was to accelerate existing component programs to ensure their availability for use on the Space Station. These components include a rotary power transfer device, remote power controllers, remote bus isolators, high power semiconductor, a high power semiconductor package, high frequency-high power cable, high frequency-high power connectors, and high frequency-high power transformers. All the components were developed to the prototype level and will be installed in the Lewis Research Center Space Station power system test bed.
High-energy laser-summator based on Raman scattering principle
NASA Astrophysics Data System (ADS)
Eugeniy Mikhalovich, Zemskov; Zarubin, Peter Vasilievich; Cook, Joung
2013-02-01
This paper is a summary of the history, theory, and development efforts of summator, an all-in-one device that coherently combines multiple high-power laser beams, lowers the beam divergence, and shifts the wavelength based on stimulated Raman scattering principle in USSR from early 1960s to late 1970s. This was a part of the Terra-3 program, which was an umbrella program of highly classified high-energy laser weapons development efforts. Some parts of the Terra-3 program, specifically the terminal missile defense portion, were declassified recently, including the information on summator development efforts.
GEECS (Generalized Equipment and Experiment Control System)
DOE Office of Scientific and Technical Information (OSTI.GOV)
GONSALVES, ANTHONY; DESHMUKH, AALHAD
2017-01-12
GEECS (Generalized Equipment and Experiment Control System) monitors and controls equipment distributed across a network, performs experiments by scanning input variables, and collects and stores various types of data synchronously from devices. Examples of devices include cameras, motors and pressure gauges. GEEKS is based upon LabView graphical object oriented programming (GOOP), allowing for a modular and scalable framework. Data is published for subscription of an arbitrary number of variables over TCP. A secondary framework allows easy development of graphical user interfaces for a combined control of any available devices on the control system without the need of programming knowledge. Thismore » allows for rapid integration of GEECS into a wide variety of systems. A database interface provides for devise and process configuration while allowing the user to save large quantities of data to local or network drives.« less
14 CFR 121.407 - Training program: Approval of airplane simulators and other training devices.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 14 Aeronautics and Space 3 2013-01-01 2013-01-01 false Training program: Approval of airplane... Program § 121.407 Training program: Approval of airplane simulators and other training devices. (a) Each airplane simulator and other training device that is used in a training course permitted under § 121.409...
14 CFR 121.407 - Training program: Approval of airplane simulators and other training devices.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 3 2011-01-01 2011-01-01 false Training program: Approval of airplane... Program § 121.407 Training program: Approval of airplane simulators and other training devices. (a) Each airplane simulator and other training device that is used in a training course permitted under § 121.409...
14 CFR 121.407 - Training program: Approval of airplane simulators and other training devices.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 14 Aeronautics and Space 3 2012-01-01 2012-01-01 false Training program: Approval of airplane... Program § 121.407 Training program: Approval of airplane simulators and other training devices. (a) Each airplane simulator and other training device that is used in a training course permitted under § 121.409...
14 CFR 121.407 - Training program: Approval of airplane simulators and other training devices.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 3 2014-01-01 2014-01-01 false Training program: Approval of airplane... Program § 121.407 Training program: Approval of airplane simulators and other training devices. Link to an amendment published at 78 FR 67836, Nov. 12, 2013. (a) Each airplane simulator and other training device...
14 CFR 121.407 - Training program: Approval of airplane simulators and other training devices.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Training program: Approval of airplane... Program § 121.407 Training program: Approval of airplane simulators and other training devices. (a) Each airplane simulator and other training device that is used in a training course permitted under § 121.409...
EXOS research on force-reflecting controllers
NASA Astrophysics Data System (ADS)
Eberman, Brian S.; An, Bin
1993-03-01
EXOS has developed two state of the art prototype master controllers for controlling robot hands and manipulators under the Small Business Innovation Research (SBIR) program with NASA. One such device is a two degree-of-freedom Sensing and Force Reflecting Exoskeleton (SAFiRE) worn on the operator's hand. The device measures the movement of the index finger and reflects the interaction forces between the slave robot and the environment to the human finger. The second device is a position sensing Exoskeleton ArmMaster (EAM) worn by a human operator. The device simultaneously tracks the motions of the operator's three DOF shoulder and two DOF elbow. Both of these devices are currently used to control robots at NASA. We are currently developing a full fingered SAFiRE and a position sensing and force reflecting EAM under two second phase SBIR grants with NASA. This paper will include discussions of: (1) the design of the current prototypes, (2) kinematics of the EAM and force control of the SAFiRE, (3) design issues that must be addressed in developing more advanced versions, and (4) our progress to date in addressing these issues.
Double-injection, deep-impurity switch development
NASA Technical Reports Server (NTRS)
Whitson, D. W.
1985-01-01
The overall objective of this program was the development of device design and process techniques for the fabrication of a double-injection, deep-impurity (DI) sup 2 silicon switch that operates in the 2-10 kV range with conduction current values of 5 A at 2 kV and 1 A at 10 kV. Other major specifications include a holding voltage of 10 V with no gate current, 10 microsec switching time, and power dissipation of 50 W at 75 C. It was decided to concentrate on the lateral circular devices in order to optimize the gold diffusion. This resulted in devices that are much better switches (approx.1 micro sec switching time), and in a gold diffusion process that is much more controllable than those previously developed. Some results with injection-gated devices were also obtained. The current conduction for V less than VT was analyzed and seen to agree, for the most part, with Lampert's theory. Various sections of this report describe the device designs, wafer-processing techniques, and various measurements which include ac and dc characteristics and four-point probe.
Biodesign process and culture to enable pediatric medical technology innovation.
Wall, James; Wynne, Elizabeth; Krummel, Thomas
2015-06-01
Innovation is the process through which new scientific discoveries are developed and promoted from bench to bedside. In an effort to encourage young entrepreneurs in this area, Stanford Biodesign developed a medical device innovation training program focused on need-based innovation. The program focuses on teaching systematic evaluation of healthcare needs, invention, and concept development. This process can be applied to any field of medicine, including Pediatric Surgery. Similar training programs have gained traction throughout the United States and beyond. Equally important to process in the success of these programs is an institutional culture that supports transformative thinking. Key components of this culture include risk tolerance, patience, encouragement of creativity, management of conflict, and networking effects. Copyright © 2015 Elsevier Inc. All rights reserved.
User centered integration of Internet of Things devices
NASA Astrophysics Data System (ADS)
Manione, Roberto
2017-06-01
This paper discusses an IoT framework which allows rapid and easy setup and customization of end-to-end solutions for field data collection and presentation; it is effective in the development of both informative and transactional applications for a wide range of application fields, such as home, industry and environment. On the "far-end" of the chain are the IoT devices gathering the signals; they are developed used a full Model Based approach, where programming is not required: the TaskScript technology is used to this purpose, which supports a choice of physical boards and boxes equipped with a range of Input and Output interfaces, and with a Tcp/Ip interface. The development of the needed specific IoT devices takes advantage of the available "standard" hardware; the software development of the algorithms for sampling, conditioning and uploading signals to the Cloud is supported by a graphical-only IDE. On the "near-end" of the chain is the presentation Interface, through which users can browse through the information provided by their IoT devices; it is implemented in a Conversational way, using the Bot paradigm: Bots are conversational automatons, to whom users can "chat". They are accessed via mainstream Messenger programs, such as Telegram(C), Skype(C) or others, available on smartphones, tablets or desktops; unlike apps, bots do not need installation on the user device. A message Broker has been implemented, to mediate among the far-end and the near-end of the chain, providing the needed services; its behavior is driven by a set of rules provided on a per-device basis, at configuration level; the Broker is able to store messages received from the devices, process and forward them to the specified recipient(s) according to the provided rules; finally, finally is it is able to send transactional commands, from users back to the requested device, to implement not only field observation but also field control. IoT solutions implemented with the proposed solution are user friendly: users can literally "chat with their devices", asking for information, providing commands, and receiving alert notifications, all with their favorite (mobile) terminal. To demonstrate de effectiveness of the proposed scenario, several solutions have been set up for industrial applications; such "mobile dashboards" are presently used by managers and technicians to keep track of their machines and plants.
Development of Si/SiGe heterostructures
NASA Astrophysics Data System (ADS)
Hauenstein, R. J.; Veteran, J. L.; Young, M. H.
1991-01-01
New molecular beam epitaxy (MBE) materials growth and doping processes were developed for the fabrication of Si/SiGe heterostructure devices. These new materials processes are applied to the demonstration of cryogenic n-p-n Si/Si 1-x Gex/Si heterojunction bipolar transistors (HBT). This application has special significance as an enabling DoD technology for fast low noise, high performance readout and signal processing circuits for IR focal systems. Reliable, versatile methods were developed to grow very high quality Si/SiGe strained layer heterostructures and multilayers. In connection with this program methods were developed to dope the Si and SiGe with B, Sb and Ga. B and Sb were found to be the preferred dopants for p and n regions respectively, of the HBT devices. The test devices clearly displayed gain enhancement due to the heterojunction and provided useful gains from room temperature down to 10 K.
Burggraaff, Marloes C; van Nispen, Ruth M A; Melis-Dankers, Bart J M; van Rens, Ger H M B
2010-03-10
Reading problems are frequently reported by visually impaired persons. A closed-circuit television (CCTV) can be helpful to maintain reading ability, however, it is difficult to learn how to use this device. In the Netherlands, an evidence-based rehabilitation program in the use of CCTVs was lacking. Therefore, a standard training protocol needed to be developed and tested in a randomized controlled trial (RCT) to provide an evidence-based training program in the use of this device. To develop a standard training program, information was collected by studying literature, observing training in the use of CCTVs, discussing the content of the training program with professionals and organizing focus and discussion groups. The effectiveness of the program was evaluated in an RCT, to obtain an evidence-based training program. Dutch patients (n = 122) were randomized into a treatment group: normal instructions from the supplier combined with training in the use of CCTVs, or into a control group: instructions from the supplier only. The effect of the training program was evaluated in terms of: change in reading ability (reading speed and reading comprehension), patients' skills to operate the CCTV, perceived (vision-related) quality of life and tasks performed in daily living. The development of the CCTV training protocol and the design of the RCT in the present study may serve as an example to obtain an evidence-based training program. The training program was adjusted to the needs and learning abilities of individual patients, however, for scientific reasons it might have been preferable to standardize the protocol further, in order to gain more comparable results. http://www.trialregister.nl, identifier: NTR1031.
2010-01-01
Background Reading problems are frequently reported by visually impaired persons. A closed-circuit television (CCTV) can be helpful to maintain reading ability, however, it is difficult to learn how to use this device. In the Netherlands, an evidence-based rehabilitation program in the use of CCTVs was lacking. Therefore, a standard training protocol needed to be developed and tested in a randomized controlled trial (RCT) to provide an evidence-based training program in the use of this device. Methods/Design To develop a standard training program, information was collected by studying literature, observing training in the use of CCTVs, discussing the content of the training program with professionals and organizing focus and discussion groups. The effectiveness of the program was evaluated in an RCT, to obtain an evidence-based training program. Dutch patients (n = 122) were randomized into a treatment group: normal instructions from the supplier combined with training in the use of CCTVs, or into a control group: instructions from the supplier only. The effect of the training program was evaluated in terms of: change in reading ability (reading speed and reading comprehension), patients' skills to operate the CCTV, perceived (vision-related) quality of life and tasks performed in daily living. Discussion The development of the CCTV training protocol and the design of the RCT in the present study may serve as an example to obtain an evidence-based training program. The training program was adjusted to the needs and learning abilities of individual patients, however, for scientific reasons it might have been preferable to standardize the protocol further, in order to gain more comparable results. Trial registration http://www.trialregister.nl, identifier: NTR1031 PMID:20219120
Medical free-electron laser: fact or fiction?
NASA Astrophysics Data System (ADS)
Bell, James P.; Ponikvar, Donald R.
1994-07-01
The free electron laser (FEL) has long been proposed as a flexible tool for a variety of medical applications, and yet the FEL has not seen widespread acceptance in the medical community. The issues have been the laser's size, cost, and complexity. Unfortunately, research on applications of FELs has outpaced the device development efforts. This paper describes the characteristics of the FEL, as they have been demonstrated in the U.S. Army's FEL technology development program, and identifies specific medical applications where demonstrated performance levels would suffice. This includes new photodynamic therapies for cancer and HIV treatment, orthopedic applications, tissue welding applications, and multiwavelength surgical techniques. A new tunable kilowatt class FEL device is described, which utilizes existing hardware from the U.S. Army program. An assessment of the future potential, based on realistic technology scaling is provided.
The Helicity Injected Torus (HIT) Program
NASA Astrophysics Data System (ADS)
Jarboe, T. R.; Gu, P.; Hamp, W.; Izzo, V.; Jewell, P.; Liptac, J.; McCollam, K. J.; Nelson, B. A.; Raman, R.; Redd, A. J.; Shumlak, U.; Sieck, P. E.; Smith, R. J.; Jain, K. K.; Nagata, M.; Uyama, T.
2000-10-01
The purpose of the Helicity Injected Torus (HIT) program is to develop current drive techniques for low-aspect-ratio toroidal plasmas. The present HIT-II spherical tokamak experiment is capable of both Coaxial Helicity Injection (CHI) and transformer action current drive. The HIT-II device itself is modestly sized (major radius R = 0.3 m, minor radius a = 0.2 m, with an on-axis magnetic field of up to Bo = 0.5 T), but has demonstrated toroidal plasma currents of up to 200 kA, using either CHI or transformer drive. An overview of ongoing research on HIT-II plasmas, including recent results, will be presented. An electron-locking model has been developed for helicity injection current drive; a description of this model will be presented, as well as comparisons to experimental results from the HIT and HIT-II devices. Empirical results from both the HIT program and past spheromak research, buttressed by theoretical developments, have led to the design of the upcoming HIT-SI (Helicity Injected Torus with Steady Inductive helicity injection) device (T.R. Jarboe, Fusion Technology 36, p. 85, 1999). HIT-SI will be able to form a high-beta spheromak, a low aspect ratio RFP or a spherical tokamak using constant inductive helicity injection. The HIT-SI design and construction progress will be presented.
Cross-Platform Development Techniques for Mobile Devices
2013-09-01
many other platforms including Windows, Blackberry , and Symbian. Each of these platforms has their own distinct architecture and programming language...sales of iPhones and the increasing use of Android-based devices have forced less successful competitors such as Microsoft, Blackberry , and Symbian... Blackberry and Windows Phone are planned [12] in this tool’s attempt to reuse code with a unified JavaScript API while at the same time supporting unique
Review of Defense Display Research Programs
2001-01-01
micromirror device (DMD) projection displays, or some future contender, such as organic light emitting diode displays (OLED)—will be installed via...Instruments (TI) digital micromirror device (DMD) technology, developed in an $11.3M research effort managed by the Air Force Research Laboratory from 1991...systems for simulator/trainer systems in the near-mid term and advanced cockpits in the far term. Such large area, curved display systems will require the
Development of Powder Processing Models and Techniques for Meso-scale Devices: Perspirable Skin
2008-03-31
of Powder Processing Models and Techniques for Meso-scale Devices: Perspirable Skin Contract Number ...Skin 5a. CONTRACT NUMBER 5b. GRANT NUMBER FA9550-05-1-0202 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) Patrick Kwon, Michigan State University 5d...PROJECT NUMBER 5e. TASK NUMBER 5f. WORK UNIT NUMBER 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) Patrick Kwon Department of
Wang, Linjie; Li, Zhili; Tan, Cheng; Liu, Shujuan; Zhang, Jianfeng; He, Siyang; Zou, Peng; Liu, Weibo; Li, Yinghui
2018-04-25
The Chinese space station will be built around 2020. As a national space laboratory, it will offer unique opportunities for studying the physiological effects of weightlessness and the efficacy of the countermeasures against such effects. In this paper, we described the development of countermeasure systems in the Chinese space program. To emphasize the need of the Chinese space program to implement its own program for developing countermeasures, we reviewed the literature on the negative physiological effects of weightlessness, the challenges of completing missions, the development of countermeasure devices, the establishment of countermeasure programs, and the efficacy of the countermeasure techniques in American and Russian manned spaceflights. In addition, a brief overview was provided on the Chinese research and development on countermeasures to discuss the current status and goals of the development of countermeasures against physiological problems associated with weightlessness.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-06
...] Pilot Program for Early Feasibility Study Investigational Device Exemption Applications; Termination of... acceptance of nominations for the Early Feasibility Study Investigational Device Exemption (IDE) Applications... technologies to participate in a pilot program for early feasibility study IDE applications. FDA is also...
NASA Technical Reports Server (NTRS)
Omalley, T. A.
1984-01-01
The use of the coupled cavity traveling wave tube for space communications has led to an increased interest in improving the efficiency of the basic interaction process in these devices through velocity resynchronization and other methods. A flexible, three dimensional, axially symmetric, large signal computer program was developed for use on the IBM 370 time sharing system. A users' manual for this program is included.
Optimizing Aspect-Oriented Mechanisms for Embedded Applications
NASA Astrophysics Data System (ADS)
Hundt, Christine; Stöhr, Daniel; Glesner, Sabine
As applications for small embedded mobile devices are getting larger and more complex, it becomes inevitable to adopt more advanced software engineering methods from the field of desktop application development. Aspect-oriented programming (AOP) is a promising approach due to its advanced modularization capabilities. However, existing AOP languages tend to add a substantial overhead in both execution time and code size which restricts their practicality for small devices with limited resources. In this paper, we present optimizations for aspect-oriented mechanisms at the level of the virtual machine. Our experiments show that these optimizations yield a considerable performance gain along with a reduction of the code size. Thus, our optimizations establish the base for using advanced aspect-oriented modularization techniques for developing Java applications on small embedded devices.
Salmons, S; Gunning, G T; Taylor, I; Grainger, S R; Hitchings, D J; Blackhurst, J; Jarvis, J C
2001-01-01
To gain a better understanding of the effects of chronic stimulation on mammalian muscles we needed to generate patterns of greater variety and complexity than simple constant-frequency or burst patterns. We describe here two approaches to the design of implantable neuromuscular stimulators that can satisfy these requirements. Devices of both types were developed and used in long-term experiments. The first device was based on a semi-custom Application Specific Integrated Circuit (ASIC). This approach has the advantage that the circuit can be completely tested at every stage of development and production, assuring a high degree of reliability. It has the drawback of inflexibility: the patterns are produced by state machines implemented in silicon, so each new set of patterns requires a fresh production run, which is costly and time-consuming. The second device was based on a commercial microcontroller (Microchip PIC16C84). The functionality of this type of circuit is specified in software rather than in silicon hardware, allowing a single device to be programmed for different functions. With the use of features designed to improve fault-tolerance we found this approach to be as reliable as that based on ASICs. The encapsulated devices can easily be accommodated subcutaneously on the flank of a rabbit and a recent version is small enough to implant into the peritoneal cavity of rats. The current devices are programmed with a predetermined set of 12 patterns before assembly; the desired pattern is selected after implantation with an electronic flash gun. The operating current drain is less than 40 microA.
Advances in Electrically Driven Thermal Management
NASA Technical Reports Server (NTRS)
Didion, Jeffrey R.
2017-01-01
Electrically Driven Thermal Management is a vibrant technology development initiative incorporating ISS based technology demonstrations, development of innovative fluid management techniques and fundamental research efforts. The program emphasizes high temperature high heat flux thermal management required for future generations of RF electronics and power electronic devices. This presentation reviews i.) preliminary results from the Electrohydrodynamic (EHD) Long Term Flight Demonstration launched on STP-H5 payload in February 2017 ii.) advances in liquid phase flow distribution control iii.) development of the Electrically Driven Liquid Film Boiling Experiment under the NASA Microgravity Fluid Physics Program.
Mobile Technology Applications in Cancer Palliative Care.
Freire de Castro Silva, Sandro Luís; Gonçalves, Antônio Augusto; Cheng, Cezar; Fernandes Martins, Carlos Henrique
2018-01-01
Mobile devices frequently used in other specialties can find great utility in palliative care. For healthcare professionals, the use of mobile technology not only can bring additional resources to the care, but it can actually radically change the cancer remote care practices. The Brazilian National Cancer Institute (INCA) has developed the largest cancer home care program in Latin America, which currently benefits more than 500 patients. The purpose of this paper is to show the development of an ICT environment of mobile applications developed to support the palliative cancer care program at INCA.
Low-background detector arrays for infrared astronomy
NASA Technical Reports Server (NTRS)
Mccreight, C. R.; Estrada, J. A.; Goebel, J. H.; Mckelvey, M. E.; Mckibbin, D. D.; Mcmurray, R. E., Jr.; Weber, T. T.
1989-01-01
The status of a program which develops and characterizes integrated infrared (IR) detector array technology for space astronomical applications is described. The devices under development include intrinsic, extrinsic silicon, and extrinsic germanium detectors, coupled to silicon readout electronics. Low-background laboratory test results include measurements of responsivity, noise, dark current, temporal response, and the effects of gamma-radiation. In addition, successful astronomical imagery has been obtained on some arrays from this program. These two aspects of the development combine to demonstrate the strong potential for integrated array technology for IR space astronomy.
[Thoughts on the Witnessed Audit in Medical Device Single Audit Program].
Wen, Jing; Xiao, Jiangyi; Wang, Aijun
2018-02-08
Medical Device Single Audit Program is one of the key projects in International Medical Device Regulators Forum, which has much experience to be used for reference. This paper briefly describes the procedures and contents of the Witnessed Audit in Medical Device Single Audit Program. Some revelations about the work of Witnessed Audit have been discussed, for reference by the Regulatory Authorities and the Auditing Organizations.
Emergency vehicle alert system (EVAS)
NASA Technical Reports Server (NTRS)
Reed, Bill; Crump, Roger; Harper, Warren; Myneni, Krishna
1995-01-01
The Emergency Vehicle Alert System (EVAS) program is sponsored by the NASA/MSFC Technology Utilization (TU) office. The program was conceived to support the needs of hearing impaired drivers. The objective of the program is to develop a low-cost, small device which can be located in a personal vehicle and warn the driver, via a visual means, of the approach of an emergency vehicle. Many different technologies might be developed for this purpose and each has its own advantages and drawbacks. The requirements for an acoustic detection system, appear to be pretty stringent and may not allow the development of a reliable, low-cost device in the near future. The problems include variations in the sirens between various types of emergency vehicles, distortions due to wind and surrounding objects, competing background noise, sophisticated signal processing requirements, and omni-directional coverage requirements. Another approach is to use a Radio Frequency (RF) signal between the Emergency Vehicle (EV) and the Personal Vehicle (PV). This approach requires a transmitter on each EV and a receiver in each PV, however it is virtually assured that a system can be developed which works. With this approach, the real technology issue is how to make a system work as inexpensively as possible. This report gives a brief summary of the EVAS program from its inception and concentrates on describing the activities that occurred during Phase 4. References 1-3 describe activities under Phases 1-3. In the fourth phase of the program, the major effort to be expended was in development of the microcontroller system for the PV, refinement of some system elements and packaging for demonstration purposes. An EVAS system was developed and demonstrated which used standard spread spectrum modems with minor modifications.
Development of high frequency low weight power magnetics for aerospace power systems
NASA Technical Reports Server (NTRS)
Schwarze, G. E.
1984-01-01
A dominant design consideration in the development of space type power mangetic devices is the application of reliable thermal control methods to prevent device failure which is due to excessive temperature rises and hot temperatures in critical areas. The resultant design must also yield low weight, high efficiency, high reliability and maintainability, and long life. The weight savings and high efficiency that results by going to high frequency and unique thermal control techniques is demonstrated by the development of a 25 kVA, 20 kHz space type transformer under the power magnetics technology program. Work in the area of power rotary transformer is also discussed.
Space shuttle propulsion estimation development verification, volume 1
NASA Technical Reports Server (NTRS)
Rogers, Robert M.
1989-01-01
The results of the Propulsion Estimation Development Verification are summarized. A computer program developed under a previous contract (NAS8-35324) was modified to include improved models for the Solid Rocket Booster (SRB) internal ballistics, the Space Shuttle Main Engine (SSME) power coefficient model, the vehicle dynamics using quaternions, and an improved Kalman filter algorithm based on the U-D factorized algorithm. As additional output, the estimated propulsion performances, for each device are computed with the associated 1-sigma bounds. The outputs of the estimation program are provided in graphical plots. An additional effort was expended to examine the use of the estimation approach to evaluate single engine test data. In addition to the propulsion estimation program PFILTER, a program was developed to produce a best estimate of trajectory (BET). The program LFILTER, also uses the U-D factorized algorithm form of the Kalman filter as in the propulsion estimation program PFILTER. The necessary definitions and equations explaining the Kalman filtering approach for the PFILTER program, the models used for this application for dynamics and measurements, program description, and program operation are presented.
Child restraint device loaner programs
DOT National Transportation Integrated Search
1981-06-01
The child restraint device (CRD) loaner programs in Tennessee were evaluated. In-Lerviews were conducted with loaner program clients in Memphis, Chattanooga, and Knoxville. Administrators of programs in all three sites also were interviewed. The prog...
Thrombotic Depositions on Right Impeller of Double-Ended Centrifugal Total Artificial Heart In Vivo.
Karimov, Jamshid H; Horvath, David J; Okano, Shinji; Goodin, Mark; Sunagawa, Gengo; Byram, Nicole; Moazami, Nader; Golding, Leonard A R; Fukamachi, Kiyotaka
2017-05-01
The development of total artificial heart devices is a complex undertaking that includes chronic biocompatibility assessment of the device. It is considered particularly important to assess whether device design and features can be compatible long term in a biological environment. As part of the development program for the Cleveland Clinic continuous-flow total artificial heart (CFTAH), we evaluated the device for signs of thrombosis and biological material deposition in four animals that had achieved the intended 14-, 30-, or 90-day durations in each respective experiment. Explanted CFTAHs were analyzed for possible clot buildup at "susceptible" areas inside the pump, particularly the right pump impeller. Depositions of various consistency and shapes were observed. We here report our findings, along with macroscopic and microscopic analysis post explant, and provide computational fluid dynamics data with its potential implications for thrombus formation. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
PHYSICAL EDUCATION FOR BOYS, GRADES 7-12.
ERIC Educational Resources Information Center
LEBOWITZ, GORDON; AND OTHERS
TEACHERS IN THE JUNIOR AND SENIOR HIGH SCHOOLS ARE PROVIDED WITH TEACHING OUTLINES, TEACHING DEVICES, AND OTHER MATERIALS TO DEVELOP PUPILS' SKILLS, APTITUDES, AND PROFICIENCY IN PHYSICAL ACTIVITIES AND SPORTS. A GRADED AND SEQUENTIAL DEVELOPMENT OF ACTIVITIES IN A UNIFIED PROGRAM, BASED UPON THE CONCEPT OF UNIT TEACHING IN SEASONAL ACTIVITIES, IS…
SIMULATION GAMING FOR MANAGEMENT DEVELOPMENT.
ERIC Educational Resources Information Center
MCKENNEY, JAMES L.
THE PRESENT HARVARD BUSINESS SCHOOL MANAGEMENT SIMULATION GAME WAS DEVELOPED AS A TEACHING DEVICE FOR CLASSES OF 20 OR MORE STUDENTS GROUPED INTO FOUR- AND FIVE-MAN TEAMS CALLED "FIRMS." EACH FIRM COMPETES WITH OTHERS IN AN "INDUSTRY," AN ECONOMIC ABSTRACTION OF A CONSUMER GOODS MARKET PROGRAMED TO BE SIMULATED ON AN ELECTRONIC…
Vegetation and other development options for mitigating urban air pollution impacts
Richard Baldauf; David J. Nowak
2014-01-01
While air pollution control devices and programs are the primary method of reducing emissions, urban air pollution can be further mitigated through planning and design strategies, including vegetation preservation and planting, building design and development, installing roadside and near-source structures, and modifying surrounding terrain features.
NASA Technical Reports Server (NTRS)
Nissley, L. E.
1979-01-01
The Aerospace Ground Equipment (AGE) provides an interface between a human operator and a complete spaceborne sequence timing device with a memory storage program. The AGE provides a means for composing, editing, syntax checking, and storing timing device programs. The AGE is implemented with a standard Hewlett-Packard 2649A terminal system and a minimum of special hardware. The terminal's dual tape interface is used to store timing device programs and to read in special AGE operating system software. To compose a new program for the timing device the keyboard is used to fill in a form displayed on the screen.
Tachycardia detection in ICDs by Boston Scientific : Algorithms, pearls, and pitfalls.
Zanker, Norbert; Schuster, Diane; Gilkerson, James; Stein, Kenneth
2016-09-01
The aim of this study was to summarize how implantable cardioverter defibrillators (ICDs) by Boston Scientific sense, detect, discriminate rhythms, and classify episodes. Modern devices include multiple programming selections, diagnostic features, therapy options, memory functions, and device-related history features. Device operation includes logical steps from sensing, detection, discrimination, therapy delivery to history recording. The program is designed to facilitate the application of the device algorithms to the individual patient's clinical needs. Features and functions described in this article represent a selective excerpt by the authors from Boston Scientific publicly available product resources. Programming of ICDs may affect patient outcomes. Patient-adapted and optimized programming requires understanding of device operation and concepts.
Acceptance of e-learning devices by dental students.
Schulz, Peter; Sagheb, Keyvan; Affeldt, Harald; Klumpp, Hannah; Taylor, Kathy; Walter, Christian; Al-Nawas, Bilal
2013-01-01
E-Learning programs and their corresponding devices are increasingly employed to educate dental students during their clinical training. Recent progress made in the development of e-learning software as well as in hardware (computers, tablet PCs, smartphones) caused us to more closely investigate into the habits of dental students in dealing with these learning techniques. Dental students during their clinical training attended a survey compiled in cooperation with biostatisticians. The questionnaire probands were asked to complete based on previous surveys of similar subjects, allowing single as well as multiple answers. The data, which were obtained with respect to the learning devices students commonly employ, were compared with their internet learning activities. The e-learning devices utilized are of heterogeneous brands. Each student has access to at least one hardware type suitable for e-learning. All students held mobile devices, about 90 percent employed laptops, and about 60 percent possess smartphones. Unexceptional all participants of the survey acknowledged an unlimited internet access. In contrast, only 16 percent of students utilized tablet PCs. A detailed analysis of the survey outcome reveals that an increasing use of mobile devices (tablet PC, smartphone) facilitates internet learning activities while at the same time utilization of computers (desktop, laptop) declines. Dental students overwhelmingly accept e-learning during their clinical training. Students report outstanding preconditions to conduct e-learning as both their access to hardware and to the internet is excellent. Less satisfying is the outcome of our survey regarding the utilization of e-learning programs. Depending of the hardware employed only one-third to barely one-half of students comprise learning programs.
Liquid Acquisition Device Testing with Sub-Cooled Liquid Oxygen
NASA Technical Reports Server (NTRS)
Jurns, John M.; McQuillen, John B.
2008-01-01
When transferring propellant in space, it is most efficient to transfer single phase liquid from a propellant tank to an engine. In earth s gravity field or under acceleration, propellant transfer is fairly simple. However, in low gravity, withdrawing single-phase fluid becomes a challenge. A variety of propellant management devices (PMD) are used to ensure single-phase flow. One type of PMD, a liquid acquisition device (LAD) takes advantage of capillary flow and surface tension to acquire liquid. Previous experimental test programs conducted at NASA have collected LAD data for a number of cryogenic fluids, including: liquid nitrogen (LN2), liquid oxygen (LOX), liquid hydrogen (LH2), and liquid methane (LCH4). The present work reports on additional testing with sub-cooled LOX as part of NASA s continuing cryogenic LAD development program. Test results extend the range of LOX fluid conditions examined, and provide insight into factors affecting predicting LAD bubble point pressures.
Sato, Yoji
2014-01-01
In 2013, the Japanese Diet passed the Regenerative Medicine Promotion Act and the revisions to the Pharmaceutical Affairs Act, which was also renamed as the Therapeutic Products Act (TPA). One of the aims of the new/revised Acts is to promote the development and translation of and access to regenerative/cellular therapies. In the TPA, a product derived from processing cells is categorized as a subgroup of "regenerative medicine, cellular therapy and gene therapy products" (RCGPs), products distinct from pharmaceuticals and medical devices, allowing RCGPs to obtain a conditional and time- limited marketing authorization much earlier than that under the conventional system. To foster not only RCGPs, but also innovative pharmaceuticals and medical devices, the Ministry of Health, Labour and Welfare recently launched Translational Research Program for Innovative Pharmaceuticals, Medical Devices and RCGPs. This mini-review introduces contributions of the National Institute of Health Sciences (NIHS) to research projects on RCGPs in the Program.
A 30 MW, 200 MHz Inductive Output Tube for RF Accelerators
DOE Office of Scientific and Technical Information (OSTI.GOV)
R. Lawrence Ives; Michael Read
2008-06-19
This program investigated development of a multiple beam inductive output tube (IOT) to produce 30 MW pulses at 200 MHz. The program was successful in demonstrating feasibility of developing the source to achieve the desired power in microsecond pulses with 70% efficiency. The predicted gain of the device is 24 dB. Consequently, a 200 kW driver would be required for the RF input. Estimated cost of this driver is approximately $1.25 M. Given the estimated development cost of the IOT of approximately $750K and the requirements for a test set that would significantly increase the cost, it was determined thatmore » development could not be achieved within the funding constraints of a Phase II program.« less
Lighnting detection and tracking with consumer electronics
NASA Astrophysics Data System (ADS)
Kamau, Gilbert; van de Giesen, Nick
2015-04-01
Lightning data is not only important for environment and weather monitoring but also for safety purposes. The AS3935 Franklin Lightning Sensor (AMS, Unterpremstaetten, Austria) is a lightning sensor developed for inclusion in consumer electronics such as watches and mobile phones. The AS3935 is small (4mmx4mm) and relatively cost effective (Eu 5). The downside is that only rough distance estimates are provided, as average power is assumed for every lightning strike. To be able to track lightning, a network of devices that monitor and keep track of occurrences of lightning strikes was developed. A communication interface was established between the sensors, a data logging circuit and a microcontroller. The digital outputs of the lightning sensor and data from a GPS are processed by the microcontroller and logged onto an SD card. The interface program enables sampling parameters such as distance from the lightning strike, time of strike occurrence and geographical location of the device. For archiving and analysis purposes, the data can be transferred from the SD card to a PC and results displayed using a graphical user interface program. Data gathered shows that the device can track the frequency and movement of lightning strikes in an area. The device has many advantages as compared to other lightning sensor stations in terms of huge memory, lower power consumption, small size, greater portability and lower cost. The devices were used in a network around Nairobi, Kenya. Through multi-lateration, lightning strikes could be located with a RMSE of 2 km or better.
Manycore Performance-Portability: Kokkos Multidimensional Array Library
Edwards, H. Carter; Sunderland, Daniel; Porter, Vicki; ...
2012-01-01
Large, complex scientific and engineering application code have a significant investment in computational kernels to implement their mathematical models. Porting these computational kernels to the collection of modern manycore accelerator devices is a major challenge in that these devices have diverse programming models, application programming interfaces (APIs), and performance requirements. The Kokkos Array programming model provides library-based approach to implement computational kernels that are performance-portable to CPU-multicore and GPGPU accelerator devices. This programming model is based upon three fundamental concepts: (1) manycore compute devices each with its own memory space, (2) data parallel kernels and (3) multidimensional arrays. Kernel executionmore » performance is, especially for NVIDIA® devices, extremely dependent on data access patterns. Optimal data access pattern can be different for different manycore devices – potentially leading to different implementations of computational kernels specialized for different devices. The Kokkos Array programming model supports performance-portable kernels by (1) separating data access patterns from computational kernels through a multidimensional array API and (2) introduce device-specific data access mappings when a kernel is compiled. An implementation of Kokkos Array is available through Trilinos [Trilinos website, http://trilinos.sandia.gov/, August 2011].« less
A Review of NASA's Radiation-Hardened Electronics for Space Environments Project
NASA Technical Reports Server (NTRS)
Keys, Andrew S.; Adams, James H.; Patrick, Marshall C.; Johnson, Michael A.; Cressler, John D.
2008-01-01
NASA's Radiation Hardened Electronics for Space Exploration (RHESE) project develops the advanced technologies required to produce radiation hardened electronics, processors, and devices in support of the requirements of NASA's Constellation program. Over the past year, multiple advancements have been made within each of the RHESE technology development tasks that will facilitate the success of the Constellation program elements. This paper provides a brief review of these advancements, discusses their application to Constellation projects, and addresses the plans for the coming year.
ERIC Educational Resources Information Center
Bauer, Stephen M.; Arthanat, Sajay
2010-01-01
The purpose of this paper was to evaluate the impact of Small Business Innovation Research (SBIR) and Small Business Technology Transfer Research (STTR) grant programs of 5 federal agencies National Institutes of Health (NIH), National Science Foundation (NSF), U.S. Department of Education (USDE), U.S. Department of Agriculture (USDA), and…
An Android Research and Development Program.
1983-03-01
reprogrammable multifunctional manipulator designed to move material, parts, tools, or special devices, through variable programmed motions for the performance...thesis: 1. An ’industrial robot’ is a [mechanized,] reprogrammable multifunctional manipulator designed to move material, parts, tools, or...insertion is also well defined in space. These manipulators are currently in use in the automobile industry, and two were were demonstrated by Kohol
Traditional Predictors of Academic Performance in a Medical School's Independent Study Program.
ERIC Educational Resources Information Center
Meleca, C. Benjamin
1995-01-01
As an initial screening device for admission to the Independent Study Program at the Ohio State University College of Medicine, a numeric value was developed for 596 first-year students. The value was based on a combination of under graduate grade point average and Medical College Admission Test scores.The predictive value of the technique was…
de Graaff, W; Grimard, B
2018-05-01
Synchronization programs using progesterone-releasing intravaginal devices that allow for fixed time artificial insemination are still finding increasing application in bovine reproduction. This practice is useful for rationalizing livestock management because an increased number of cows can be inseminated in one session without the need for estrus detection. Although much of the innovation related to the design and development of intravaginal devices for use in cattle took place in the previous century, progress in understanding the physiology of the bovine estrous cycle resulted in shorter treatment durations, a trend which is still continuing. In this competitive market, with little functional differentiation between the existing devices, the shorter treatment duration prompted for optimization of the progesterone content in the device, as the cost of the drug significantly contributes to the price per unit. For CIDR ® a reduction of the progesterone content of about 30 per cent was realized. Price reduction remained an important target for further device development. Next to reduction of progesterone content, cheaper and easier to process materials like polyethylene vinyl acetate (EVA) copolymers have been explored to replace the commonly used silicone elastomers. The reengineering effort of CIDR ® demonstrated that knowledge of release kinetics and insight into gradual depletion patterns in the device is critical for optimization of drug content without compromising performance (blood levels). More recent publications related to the use of alternative polymers like EVA and polyisoprene (IP) indicated encouraging results regarding further reduction of progesterone content. The use of EVA seems most promising, because it is in principle a low-cost polymer available in many grades and this thermoplastic polymer can be processed easily by means of commonly used techniques like injection molding and extrusion. The use of thermoplastic polymers, however, requires insight into the physical-chemical phenomena related to drug dissolution and re-crystallization taking place in the polymer during processing at high temperatures. These aspects, which may critically affect product stability, are often overlooked and are prompting to cover some of the background in this review. Finally, two different innovative approaches are discussed, one related to programable electronic devices for tailored simultaneous drug release and the other is a flexible drug-loaded helix, which is retained very well in several species without causing the usual inflammatory response. Copyright © 2017 Elsevier Inc. All rights reserved.
A new attempt using LabVIEW into a computational experiment of plasma focus device
NASA Astrophysics Data System (ADS)
Kim, Myungkyu
2017-03-01
The simulation program of plasma focus device based on S. Lee's model has been first developed since 30 years ago and it is widely used to date. Originally the program made by GWbasic language, and then modified by visual basic which was included in the Microsoft Excel. Using Excel well-known to researchers is a key advantage of this program. But it has disadvantages in displaying data in same graph, in slow calculation speed, and in displaying data and calculation of smaller time step. To overcome all these points, the LabVIEW that made by national instrument and based on graphical environment is used for simulation. Furthermore it is correlated with data acquisition of experiment, once experiment being the data is directly transferred to the simulation program and then analyzes and predicts for the next shot. The mass swept factor (fm) and current factor (fc) can be easily find out using this program. This paper describes the detail function and usage of the program and compares the results with the existing one.
URobotics—Urology Robotics at Johns Hopkins
Stoianovici, D
2011-01-01
URobotics (Urology Robotics) is a program of the Urology Department at the Johns Hopkins Medical Institutions dedicated to the development of new technology for urologic surgery (http://urology.jhu.edu/urobotics). The program is unique in that it is the only academic engineering program exclusively applied to urology. The program combines efforts and expertise from the medical and engineering fields through a close partnership of clinical and technical personnel. Since its creation in 1996, the URobotics lab has created several devices, instruments, and robotic systems, several of which have been successfully used in the operating room. This article reviews the technology developed in our laboratory and its surgical applications, and highlights our future directions. PMID:11954067
Current status and future R&D for reduced-activation ferritic/martensitic steels
NASA Astrophysics Data System (ADS)
Hishinuma, A.; Kohyama, A.; Klueh, R. L.; Gelles, D. S.; Dietz, W.; Ehrlich, K.
1998-10-01
International research and development programs on reduced-activation ferritic/martensitic steels, the primary candidate-alloys for a DEMO fusion reactor and beyond, are briefly summarized, along with some information on conventional steels. An International Energy Agency (IEA) collaborative test program to determine the feasibility of reduced-activation ferritic/martensitic steels for fusion is in progress and will be completed within this century. Baseline properties including typical irradiation behavior for Fe-(7-9)%Cr reduced-activation ferritic steels are shown. Most of the data are for a heat of modified F82H steel, purchased for the IEA program. Experimental plans to explore possible problems and solutions for fusion devices using ferromagnetic materials are introduced. The preliminary results show that it should be possible to use a ferromagnetic vacuum vessel in tokamak devices.
Breadboard stellar tracker system test report
NASA Technical Reports Server (NTRS)
Kollodge, J. C.; Parrish, K. A.
1984-01-01
BASD has, in the past, developed several unique position tracking algorithms for charge transfer device (CTD) sensors. These algorithms provide an interpixel transfer function with the following characteristics: (1) high linearity; (2) simplified track logic; (3) high gain; and (4) high noise rejection. A previous test program using the GE charge injection device (CID) showed that accuracy for BASD's breadboard was limited to approximately 2% of a pixel (1 sigma) whereas analysis and simulation indicated the limit should be less than 0.5% of a pixel, assuming the limit to be detector response and dark current noise. The test program was conducted under NASA contract No. NAS8-34263. The test approach for that program did not provide sufficient data to identify the sources of error and left open the amount of contribution from parameters such as image distribution, geometric distortion and system alignment errors.
Extended-gate organic field-effect transistor for the detection of histamine in water
NASA Astrophysics Data System (ADS)
Minamiki, Tsukuru; Minami, Tsuyoshi; Yokoyama, Daisuke; Fukuda, Kenjiro; Kumaki, Daisuke; Tokito, Shizuo
2015-04-01
As part of our ongoing research program to develop health care sensors based on organic field-effect transistor (OFET) devices, we have attempted to detect histamine using an extended-gate OFET. Histamine is found in spoiled or decayed fish, and causes foodborne illness known as scombroid food poisoning. The new OFET device possesses an extended gate functionalized by carboxyalkanethiol that can interact with histamine. As a result, we have succeeded in detecting histamine in water through a shift in OFET threshold voltage. This result indicates the potential utility of the designed OFET devices in food freshness sensing.
Yoon, Chiyul; Noh, Seungwoo; Lee, Jung Chan; Ko, Sung Ho; Ahn, Wonsik; Kim, Hee Chan
2014-03-01
The continuous autotransfusion system has been widely used in surgical operations. It is known that if oil is added to blood, and this mixture is then processed by an autotransfusion device, the added oil is removed and reinfusion of fat is prevented by the device. However, there is no detailed report on the influence of the particular washing program selected on the levels of blood components including blood fat after continuous autotransfusion using such a system. Fresh bovine blood samples were processed by a commercial continuous autotransfusion device using the "emergency," "quality," and "high-quality" programs, applied in random order. Complete blood count (CBC) and serum chemistry were analyzed to determine how the blood processing performance of the device changes with the washing program applied. There was no significant difference in the CBC results obtained with the three washing programs. Although all of the blood lipids in the processed blood were decreased compared to those in the blood before processing, the levels of triglyceride, phospholipid, and total cholesterol after processing via the emergency program were significantly higher than those present after processing via the quality and high-quality programs. Although the continuous autotransfusion device provided consistent hematocrit quality, the levels of some blood lipid components showed significant differences among the washing programs.
A pilot biomedical engineering course in rapid prototyping for mobile health.
Stokes, Todd H; Venugopalan, Janani; Hubbard, Elena N; Wang, May D
2013-01-01
Rapid prototyping of medically assistive mobile devices promises to fuel innovation and provides opportunity for hands-on engineering training in biomedical engineering curricula. This paper presents the design and outcomes of a course offered during a 16-week semester in Fall 2011 with 11 students enrolled. The syllabus covered a mobile health design process from end-to-end, including storyboarding, non-functional prototypes, integrated circuit programming, 3D modeling, 3D printing, cloud computing database programming, and developing patient engagement through animated videos describing the benefits of a new device. Most technologies presented in this class are open source and thus provide unlimited "hackability". They are also cost-effective and easily transferrable to other departments.
NASA Technical Reports Server (NTRS)
Didion, Jeffrey R.
2018-01-01
Electrically Driven Thermal Management is an active research and technology development initiative incorporating ISS technology flight demonstrations (STP-H5), development of Microgravity Science Glovebox (MSG) flight experiment, and laboratory-based investigations of electrically based thermal management techniques. The program targets integrated thermal management for future generations of RF electronics and power electronic devices. This presentation reviews four program elements: i.) results from the Electrohydrodynamic (EHD) Long Term Flight Demonstration launched in February 2017 ii.) development of the Electrically Driven Liquid Film Boiling Experiment iii.) two University based research efforts iv.) development of Oscillating Heat Pipe evaluation at Goddard Space Flight Center.
NASA Technical Reports Server (NTRS)
Mcgreevy, Michael W.
1990-01-01
An advanced human-system interface is being developed for evolutionary Space Station Freedom as part of the NASA Office of Space Station (OSS) Advanced Development Program. The human-system interface is based on body-pointed display and control devices. The project will identify and document the design accommodations ('hooks and scars') required to support virtual workstations and telepresence interfaces, and prototype interface systems will be built, evaluated, and refined. The project is a joint enterprise of Marquette University, Astronautics Corporation of America (ACA), and NASA's ARC. The project team is working with NASA's JSC and McDonnell Douglas Astronautics Company (the Work Package contractor) to ensure that the project is consistent with space station user requirements and program constraints. Documentation describing design accommodations and tradeoffs will be provided to OSS, JSC, and McDonnell Douglas, and prototype interface devices will be delivered to ARC and JSC. ACA intends to commercialize derivatives of the interface for use with computer systems developed for scientific visualization and system simulation.
Multijunction Solar Cell Technology for Mars Surface Applications
NASA Technical Reports Server (NTRS)
Stella, Paul M.; Mardesich, Nick; Ewell, Richard C.; Mueller, Robert L.; Endicter, Scott; Aiken, Daniel; Edmondson, Kenneth; Fetze, Chris
2006-01-01
Solar cells used for Mars surface applications have been commercial space qualified AM0 optimized devices. Due to the Martian atmosphere, these cells are not optimized for the Mars surface and as a result operate at a reduced efficiency. A multi-year program, MOST (Mars Optimized Solar Cell Technology), managed by JPL and funded by NASA Code S, was initiated in 2004, to develop tools to modify commercial AM0 cells for the Mars surface solar spectrum and to fabricate Mars optimized devices for verification. This effort required defining the surface incident spectrum, developing an appropriate laboratory solar simulator measurement capability, and to develop and test commercial cells modified for the Mars surface spectrum. This paper discusses the program, including results for the initial modified cells. Simulated Mars surface measurements of MER cells and Phoenix Lander cells (2007 launch) are provided to characterize the performance loss for those missions. In addition, the performance of the MER rover solar arrays is updated to reflect their more than two (2) year operation.
Technology-based suicide prevention: current applications and future directions.
Luxton, David D; June, Jennifer D; Kinn, Julie T
2011-01-01
This review reports on current and emerging technologies for suicide prevention. Technology-based programs discussed include interactive educational and social networking Web sites, e-mail outreach, and programs that use mobile devices and texting. We describe innovative applications such as virtual worlds, gaming, and text analysis that are currently being developed and applied to suicide prevention and outreach programs. We also discuss the benefits and limitations of technology-based applications and discuss future directions for their use.
NASA Technical Reports Server (NTRS)
Omalley, T. A.; Connolly, D. J.
1977-01-01
The use of the coupled cavity traveling wave tube for space communications has led to an increased interest in improving the efficiency of the basic interaction process in these devices through velocity resynchronization and other methods. To analyze these methods, a flexible, large signal computer program for use on the IBM 360/67 time-sharing system has been developed. The present report is a users' manual for this program.
IMAPS Device Packaging Conference 2017 - Engineered Micro Systems & Devices Track
NASA Technical Reports Server (NTRS)
Varnavas, Kosta
2017-01-01
NASA field center Marshall Space Flight Center (Huntsville, AL), has invested in advanced wireless sensor technology development. Developments for a wireless microcontroller back-end were primarily focused on the commercial Synapse Wireless family of devices. These devices have many useful features for NASA applications, good characteristics and the ability to be programmed Over-The-Air (OTA). The effort has focused on two widely used sensor types, mechanical strain gauges and thermal sensors. Mechanical strain gauges are used extensively in NASA structural testing and even on vehicle instrumentation systems. Additionally, thermal monitoring with many types of sensors is extensively used. These thermal sensors include thermocouples of all types, resistive temperature devices (RTDs), diodes and other thermal sensor types. The wireless thermal board will accommodate all of these types of sensor inputs to an analog front end. The analog front end on each of the sensors interfaces to the Synapse wireless microcontroller, based on the Atmel Atmega128 device. Once the analog sensor output data is digitized by the onboard analog to digital converter (A/D), the data is available for analysis, computation or transmission. Various hardware features allow custom embedded software to manage battery power to enhance battery life. This technology development fits nicely into using numerous additional sensor front ends, including some of the low-cost printed circuit board capacitive moisture content sensors currently being developed at Auburn University.
The MMI Device Ontology: Enabling Sensor Integration
NASA Astrophysics Data System (ADS)
Rueda, C.; Galbraith, N.; Morris, R. A.; Bermudez, L. E.; Graybeal, J.; Arko, R. A.; Mmi Device Ontology Working Group
2010-12-01
The Marine Metadata Interoperability (MMI) project has developed an ontology for devices to describe sensors and sensor networks. This ontology is implemented in the W3C Web Ontology Language (OWL) and provides an extensible conceptual model and controlled vocabularies for describing heterogeneous instrument types, with different data characteristics, and their attributes. It can help users populate metadata records for sensors; associate devices with their platforms, deployments, measurement capabilities and restrictions; aid in discovery of sensor data, both historic and real-time; and improve the interoperability of observational oceanographic data sets. We developed the MMI Device Ontology following a community-based approach. By building on and integrating other models and ontologies from related disciplines, we sought to facilitate semantic interoperability while avoiding duplication. Key concepts and insights from various communities, including the Open Geospatial Consortium (eg., SensorML and Observations and Measurements specifications), Semantic Web for Earth and Environmental Terminology (SWEET), and W3C Semantic Sensor Network Incubator Group, have significantly enriched the development of the ontology. Individuals ranging from instrument designers, science data producers and consumers to ontology specialists and other technologists contributed to the work. Applications of the MMI Device Ontology are underway for several community use cases. These include vessel-mounted multibeam mapping sonars for the Rolling Deck to Repository (R2R) program and description of diverse instruments on deepwater Ocean Reference Stations for the OceanSITES program. These trials involve creation of records completely describing instruments, either by individual instances or by manufacturer and model. Individual terms in the MMI Device Ontology can be referenced with their corresponding Uniform Resource Identifiers (URIs) in sensor-related metadata specifications (e.g., SensorML, NetCDF). These identifiers can be resolved through a web browser, or other client applications via HTTP against the MMI Ontology Registry and Repository (ORR), where the ontology is maintained. SPARQL-based query capabilities, which are enhanced with reasoning, along with several supported output formats, allow the effective interaction of diverse client applications with the semantic information associated with the device ontology. In this presentation we describe the process for the development of the MMI Device Ontology and illustrate extensions and applications that demonstrate the benefits of adopting this semantic approach, including example queries involving inference. We also highlight the issues encountered and future work.
ARCGRAPH SYSTEM - AMES RESEARCH GRAPHICS SYSTEM
NASA Technical Reports Server (NTRS)
Hibbard, E. A.
1994-01-01
Ames Research Graphics System, ARCGRAPH, is a collection of libraries and utilities which assist researchers in generating, manipulating, and visualizing graphical data. In addition, ARCGRAPH defines a metafile format that contains device independent graphical data. This file format is used with various computer graphics manipulation and animation packages at Ames, including SURF (COSMIC Program ARC-12381) and GAS (COSMIC Program ARC-12379). In its full configuration, the ARCGRAPH system consists of a two stage pipeline which may be used to output graphical primitives. Stage one is associated with the graphical primitives (i.e. moves, draws, color, etc.) along with the creation and manipulation of the metafiles. Five distinct data filters make up stage one. They are: 1) PLO which handles all 2D vector primitives, 2) POL which handles all 3D polygonal primitives, 3) RAS which handles all 2D raster primitives, 4) VEC which handles all 3D raster primitives, and 5) PO2 which handles all 2D polygonal primitives. Stage two is associated with the process of displaying graphical primitives on a device. To generate the various graphical primitives, create and reprocess ARCGRAPH metafiles, and access the device drivers in the VDI (Video Device Interface) library, users link their applications to ARCGRAPH's GRAFIX library routines. Both FORTRAN and C language versions of the GRAFIX and VDI libraries exist for enhanced portability within these respective programming environments. The ARCGRAPH libraries were developed on a VAX running VMS. Minor documented modification of various routines, however, allows the system to run on the following computers: Cray X-MP running COS (no C version); Cray 2 running UNICOS; DEC VAX running BSD 4.3 UNIX, or Ultrix; SGI IRIS Turbo running GL2-W3.5 and GL2-W3.6; Convex C1 running UNIX; Amhdahl 5840 running UTS; Alliant FX8 running UNIX; Sun 3/160 running UNIX (no native device driver); Stellar GS1000 running Stellex (no native device driver); and an SGI IRIS 4D running IRIX (no native device driver). Currently with version 7.0 of ARCGRAPH, the VDI library supports the following output devices: A VT100 terminal with a RETRO-GRAPHICS board installed, a VT240 using the Tektronix 4010 emulation capability, an SGI IRIS turbo using the native GL2 library, a Tektronix 4010, a Tektronix 4105, and the Tektronix 4014. ARCGRAPH version 7.0 was developed in 1988.
Microarthroscopy System With Image Processing Technology Developed for Minimally Invasive Surgery
NASA Technical Reports Server (NTRS)
Steele, Gynelle C.
2001-01-01
In a joint effort, NASA, Micro Medical Devices, and the Cleveland Clinic have developed a microarthroscopy system with digital image processing. This system consists of a disposable endoscope the size of a needle that is aimed at expanding the use of minimally invasive surgery on the knee, ankle, and other small joints. This device not only allows surgeons to make smaller incisions (by improving the clarity and brightness of images), but it gives them a better view of the injured area to make more accurate diagnoses. Because of its small size, the endoscope helps reduce physical trauma and speeds patient recovery. The faster recovery rate also makes the system cost effective for patients. The digital image processing software used with the device was originally developed by the NASA Glenn Research Center to conduct computer simulations of satellite positioning in space. It was later modified to reflect lessons learned in enhancing photographic images in support of the Center's microgravity program. Glenn's Photovoltaic Branch and Graphics and Visualization Lab (G-VIS) computer programmers and software developers enhanced and speed up graphic imaging for this application. Mary Vickerman at Glenn developed algorithms that enabled Micro Medical Devices to eliminate interference and improve the images.
Shukla, Krishna Dayal; Saxena, Nishant; Manivannan, Anbarasu
2017-12-01
Recent advancements in commercialization of high-speed non-volatile electronic memories including phase change memory (PCM) have shown potential not only for advanced data storage but also for novel computing concepts. However, an in-depth understanding on ultrafast electrical switching dynamics is a key challenge for defining the ultimate speed of nanoscale memory devices that demands for an unconventional electrical setup, specifically capable of handling extremely fast electrical pulses. In the present work, an ultrafast programmable electrical tester (PET) setup has been developed exceptionally for unravelling time-resolved electrical switching dynamics and programming characteristics of nanoscale memory devices at the picosecond (ps) time scale. This setup consists of novel high-frequency contact-boards carefully designed to capture extremely fast switching transient characteristics within 200 ± 25 ps using time-resolved current-voltage measurements. All the instruments in the system are synchronized using LabVIEW, which helps to achieve various programming characteristics such as voltage-dependent transient parameters, read/write operations, and endurance test of memory devices systematically using short voltage pulses having pulse parameters varied from 1 ns rise/fall time and 1.5 ns pulse width (full width half maximum). Furthermore, the setup has successfully demonstrated strikingly one order faster switching characteristics of Ag 5 In 5 Sb 60 Te 30 (AIST) PCM devices within 250 ps. Hence, this novel electrical setup would be immensely helpful for realizing the ultimate speed limits of various high-speed memory technologies for future computing.
NASA Astrophysics Data System (ADS)
Shukla, Krishna Dayal; Saxena, Nishant; Manivannan, Anbarasu
2017-12-01
Recent advancements in commercialization of high-speed non-volatile electronic memories including phase change memory (PCM) have shown potential not only for advanced data storage but also for novel computing concepts. However, an in-depth understanding on ultrafast electrical switching dynamics is a key challenge for defining the ultimate speed of nanoscale memory devices that demands for an unconventional electrical setup, specifically capable of handling extremely fast electrical pulses. In the present work, an ultrafast programmable electrical tester (PET) setup has been developed exceptionally for unravelling time-resolved electrical switching dynamics and programming characteristics of nanoscale memory devices at the picosecond (ps) time scale. This setup consists of novel high-frequency contact-boards carefully designed to capture extremely fast switching transient characteristics within 200 ± 25 ps using time-resolved current-voltage measurements. All the instruments in the system are synchronized using LabVIEW, which helps to achieve various programming characteristics such as voltage-dependent transient parameters, read/write operations, and endurance test of memory devices systematically using short voltage pulses having pulse parameters varied from 1 ns rise/fall time and 1.5 ns pulse width (full width half maximum). Furthermore, the setup has successfully demonstrated strikingly one order faster switching characteristics of Ag5In5Sb60Te30 (AIST) PCM devices within 250 ps. Hence, this novel electrical setup would be immensely helpful for realizing the ultimate speed limits of various high-speed memory technologies for future computing.
Hand controller commonality evaluation process
NASA Technical Reports Server (NTRS)
Stuart, Mark A.; Bierschwale, John M.; Wilmington, Robert P.; Adam, Susan C.; Diaz, Manuel F.; Jensen, Dean G.
1990-01-01
A hand controller evaluation process has been developed to determine the appropriate hand controller configurations for supporting remotely controlled devices. These devices include remote manipulator systems (RMS), dexterous robots, and remotely-piloted free flyers. Standard interfaces were developed to evaluate six different hand controllers in three test facilities including dynamic computer simulations, kinematic computer simulations, and physical simulations. The hand controllers under consideration were six degree-of-freedom (DOF) position and rate minimaster and joystick controllers, and three-DOF rate controllers. Task performance data, subjective comments, and anthropometric data obtained during tests were used for controller configuration recommendations to the SSF Program.
MEMS applications in space exploration
NASA Astrophysics Data System (ADS)
Tang, William C.
1997-09-01
Space exploration in the coming century will emphasize cost effectiveness and highly focused mission objectives, which will result in frequent multiple missions that broaden the scope of space science and to validate new technologies on a timely basis. MEMS is one of the key enabling technology to create cost-effective, ultra-miniaturized, robust, and functionally focused spacecraft for both robotic and human exploration programs. Examples of MEMS devices at various stages of development include microgyroscope, microseismometer, microhygrometer, quadrupole mass spectrometer, and micropropulsion engine. These devices, when proven successful, will serve as models for developing components and systems for new-millennium spacecraft.
Applications of MEMS for Space Exploration
NASA Astrophysics Data System (ADS)
Tang, William C.
1998-03-01
Space exploration in the coming century will emphasize cost effectiveness and highly focused mission objectives, which will result in frequent multiple missions that broaden the scope of space science and to validate new technologies on a timely basis. Micro Electro Mechanical Systems (MEMS) is one of the key enabling technologies to create cost-effective, ultra-miniaturized, robust, and functionally focused spacecraft for both robotic and human exploration programs. Examples of MEMS devices at various stages of development include microgyroscope, microseismometer, microhygrometer, quadrupole mass spectrometer, and micropropulsion engine. These devices, when proven successful, will serve as models for developing components and systems for new-millennium spacecraft.
Battery Test Manual For 12 Volt Start/Stop Hybrid Electric Vehicles
DOE Office of Scientific and Technical Information (OSTI.GOV)
Belt, Jeffrey R.
This manual was prepared by and for the United Stated Advanced Battery Consortium (USABC) Electrochemical Energy Storage Team. It is based on the targets established for 12 Volt Start/Stop energy storage development and is similar (with some important changes) to an earlier manual for the former FreedomCAR program. The specific procedures were developed primarily to characterize the performance of energy storage devices relative to the USABC requirements. However, it is anticipated that these procedures will have some utility for characterizing 12 Volt Start/Stop hybrid energy storage device behavior in general.
NASA Technical Reports Server (NTRS)
Gassaway, J. D.; Mahmood, Q.; Trotter, J. D.
1980-01-01
Quarterly report describes progress in three programs: dc sputtering machine for aluminum and aluminum alloys; two dimensional computer modeling of MOS transistors; and development of computer techniques for calculating redistribution diffusion of dopants in silicon on sapphire films.
48 CFR 1823.7101 - Contract clause.
Code of Federal Regulations, 2013 CFR
2013-10-01
... SOCIOECONOMIC PROGRAMS ENVIRONMENT, ENERGY AND WATER EFFICIENCY, RENEWABLE ENERGY TECHNOLOGIES, OCCUPATIONAL SAFETY, AND DRUG-FREE WORKPLACE Frequency Authorization 1823.7101 Contract clause. The contracting... calling for developing, producing, constructing, testing, or operating a device for which a radio...
In-Field Performance Testing of Stormwater Treatment Devices
The Environmental Technology Verification (ETV) Program was created by EPA’s Office of Research and Development to facilitate the deployment of innovative or improved environmental technologies through performance verification and dissemination of information. The program’s goal ...
McClelland, Molly; Kleinke, Darrell
2013-07-01
University students are trained in specific disciplines, which can benefit disabled individuals in a variety of ways, including education, health promotion, assistive technologies, logistics, or design improvement. However, collaboration with other disciplines can have a greater impact on improving the health of disabled individuals than can training in one discipline alone. The University of Detroit Mercy Colleges of Engineering and Nursing have partnered to develop and provide assistive devices to disabled individuals while teaching innovation, technology, and collaboration to students. After 4 years of developing and implementing our multidisciplinary program, numerous unique and helpful assistive devices have been designed, created, and delivered to individuals in our community. More nursing schools should initiate multidisciplinary programs to train and prepare students for workplaces where such innovative, collaborative skills are increasingly sought. Nurses need to be at the forefront of such collaborative work. Copyright 2013, SLACK Incorporated.
NASA Technical Reports Server (NTRS)
Pagnutti, Mary; Ryan, Robert E.; Holekamp, Kara; Harrington, Gary; Frisbie, Troy
2006-01-01
A simple and cost-effective, hyperspectral sun photometer for radiometric vicarious remote sensing system calibration, air quality monitoring, and potentially in-situ planetary climatological studies, was developed. The device was constructed solely from off the shelf components and was designed to be easily deployable for support of short-term verification and validation data collects. This sun photometer not only provides the same data products as existing multi-band sun photometers, this device requires a simpler setup, less data acquisition time and allows for a more direct calibration approach. Fielding this instrument has also enabled Stennis Space Center (SSC) Applied Sciences Directorate personnel to cross calibrate existing sun photometers. This innovative research will position SSC personnel to perform air quality assessments in support of the NASA Applied Sciences Program's National Applications program element as well as to develop techniques to evaluate aerosols in a Martian or other planetary atmosphere.
Status of the Combustion Devices Injector Technology Program at the NASA MSFC
NASA Technical Reports Server (NTRS)
Jones, Gregg; Protz, Christopher; Trinh, Huu; Tucker, Kevin; Nesman, Tomas; Hulka, James
2005-01-01
To support the NASA Space Exploration Mission, an in-house program called Combustion Devices Injector Technology (CDIT) is being conducted at the NASA Marshall Space Flight Center (MSFC) for the fiscal year 2005. CDIT is focused on developing combustor technology and analysis tools to improve reliability and durability of upper-stage and in-space liquid propellant rocket engines. The three areas of focus include injector/chamber thermal compatibility, ignition, and combustion stability. In the compatibility and ignition areas, small-scale single- and multi-element hardware experiments will be conducted to demonstrate advanced technological concepts as well as to provide experimental data for validation of computational analysis tools. In addition, advanced analysis tools will be developed to eventually include 3-dimensional and multi- element effects and improve capability and validity to analyze heat transfer and ignition in large, multi-element injectors.
Kerkhof, Yvonne J F; Graff, Maud J L; Bergsma, Ad; de Vocht, Hilde H M; Dröes, Rose-Marie
2016-11-01
To offer good support to people with dementia and their carers in an aging and Internet society the deployment of hand-held touch screen devices, better known as tablets, and its applications (apps) can be viable and desirable. However, at the moment it is not clear which apps are usable for supporting people with dementia in daily life. Also, little is known about how people with dementia can be coached to learn to use a tablet and its apps. A person-centered program, with tools and training, will be developed that aims to support people with mild dementia and their (in)formal carers in how to use the tablet for self-management and meaningful activities. The program will be developed in accordance with the Medical Research Council's (MRC) framework for developing and evaluating complex interventions and the study will cover the following phases: a preclinical or theoretical (0) phase; a modeling phase (I) and the exploratory trial phase (II). The users (people with dementia and their carers) will be involved intensively during all these phases, by means of individual interviews, workshops, focus groups, and case studies. The iterative process inherent to this framework makes it possible to develop a user-oriented intervention, in this case a person-centered program, for the use of tablets in dementia care. Preparatory work will be done to perform a methodologically sound randomized controlled trial (RCT) in the near future, which aims to investigate the contribution of this person-centered program for tablet use to the quality of life of people with dementia and their carers.
Erbes, Christopher R; Stinson, Rebecca; Kuhn, Eric; Polusny, Melissa; Urban, Jessica; Hoffman, Julia; Ruzek, Josef I; Stepnowsky, Carl; Thorp, Steven R
2014-11-01
Mobile health (mHealth) refers to the use of mobile technology (e.g., smartphones) and software (i.e., applications) to facilitate or enhance health care. Several mHealth programs act as either stand-alone aids for Veterans with post-traumatic stress disorder (PTSD) or adjuncts to conventional psychotherapy approaches. Veterans enrolled in a Veterans Affairs outpatient treatment program for PTSD (N = 188) completed anonymous questionnaires that assessed Veterans' access to mHealth-capable devices and their utilization of and interest in mHealth programs for PTSD. The majority of respondents (n = 142, 76%) reported having access to a cell phone or tablet capable of running applications, but only a small group (n = 18) reported use of existing mHealth programs for PTSD. Age significantly predicted ownership of mHealth devices, but not utilization or interest in mHealth applications among device owners. Around 56% to 76% of respondents with access indicated that they were interested in trying mHealth programs for such issues as anger management, sleep hygiene, and management of anxiety symptoms. Findings from this sample suggest that Veterans have adequate access to, and interest in, using mHealth applications to warrant continued development and evaluation of mobile applications for the treatment of PTSD and other mental health conditions. Reprint & Copyright © 2014 Association of Military Surgeons of the U.S.
Maidenbaum, Shachar; Levy-Tzedek, Shelly; Chebat, Daniel Robert; Namer-Furstenberg, Rinat; Amedi, Amir
2014-01-01
Mobility training programs for helping the blind navigate through unknown places with a White-Cane significantly improve their mobility. However, what is the effect of new assistive technologies, offering more information to the blind user, on the underlying premises of these programs such as navigation patterns? We developed the virtual-EyeCane, a minimalistic sensory substitution device translating single-point-distance into auditory cues identical to the EyeCane's in the real world. We compared performance in virtual environments when using the virtual-EyeCane, a virtual-White-Cane, no device and visual navigation. We show that the characteristics of virtual-EyeCane navigation differ from navigation with a virtual-White-Cane or no device, and that virtual-EyeCane users complete more levels successfully, taking shorter paths and with less collisions than these groups, and we demonstrate the relative similarity of virtual-EyeCane and visual navigation patterns. This suggests that additional distance information indeed changes navigation patterns from virtual-White-Cane use, and brings them closer to visual navigation.
Real-time volume rendering of digital medical images on an iOS device
NASA Astrophysics Data System (ADS)
Noon, Christian; Holub, Joseph; Winer, Eliot
2013-03-01
Performing high quality 3D visualizations on mobile devices, while tantalizingly close in many areas, is still a quite difficult task. This is especially true for 3D volume rendering of digital medical images. Allowing this would empower medical personnel a powerful tool to diagnose and treat patients and train the next generation of physicians. This research focuses on performing real time volume rendering of digital medical images on iOS devices using custom developed GPU shaders for orthogonal texture slicing. An interactive volume renderer was designed and developed with several new features including dynamic modification of render resolutions, an incremental render loop, a shader-based clipping algorithm to support OpenGL ES 2.0, and an internal backface culling algorithm for properly sorting rendered geometry with alpha blending. The application was developed using several application programming interfaces (APIs) such as OpenSceneGraph (OSG) as the primary graphics renderer coupled with iOS Cocoa Touch for user interaction, and DCMTK for DICOM I/O. The developed application rendered volume datasets over 450 slices up to 50-60 frames per second, depending on the specific model of the iOS device. All rendering is done locally on the device so no Internet connection is required.
Mars Science Laboratory CHIMRA: A Device for Processing Powdered Martian Samples
NASA Technical Reports Server (NTRS)
Sunshine, Daniel
2010-01-01
The CHIMRA is an extraterrestrial sample acquisition and processing device for the Mars Science Laboratory that emphasizes robustness and adaptability through design configuration. This work reviews the guidelines utilized to invent the initial CHIMRA and the strategy employed in advancing the design; these principles will be discussed in relation to both the final CHIMRA design and similar future devices. The computational synthesis necessary to mature a boxed-in impact-generating mechanism will be presented alongside a detailed mechanism description. Results from the development testing required to advance the design for a highly-loaded, long-life and high-speed bearing application will be presented. Lessons learned during the assembly and testing of this subsystem as well as results and lessons from the sample-handling development test program will be reviewed.
Man-machine interface issues in space telerobotics: A JPL research and development program
NASA Technical Reports Server (NTRS)
Bejczy, A. K.
1987-01-01
Technology issues related to the use of robots as man-extension or telerobot systems in space are discussed and exemplified. General considerations are presentd on control and information problems in space teleoperation and on the characteristics of Earth orbital teleoperation. The JPL R and D work in the area of man-machine interface devices and techniques for sensing and computer-based control is briefly summarized. The thrust of this R and D effort is to render space teleoperation efficient and safe through the use of devices and techniques which will permit integrated and task-level (intelligent) two-way control communication between human operator and telerobot machine in Earth orbit. Specific control and information display devices and techniques are discussed and exemplified with development results obtained at JPL in recent years.
An assessment of health hazard/health risk appraisal.
Wagner, E H; Beery, W L; Schoenbach, V J; Graham, R M
1982-01-01
A state-of-the-art review of a widely-used health promotion technique, the health hazard/health risk appraisal (HHA/HRA), was conducted. The review included preparing a 212-item annotated bibliography, compiling an inventory of 217 programs that have used HHA/HRA, holding discussions with HHA/HRA developers and users, conducting formal site visits to 15 HHA/HRA programs, and consultation with experts on epidemiology, biostatistics, and behavioral science as well as developers and users of HHA/HRA. Programs use HHA/HRA primarily as a promotional device, as a tool for structuring education about health-related behaviors, and as a motivational device for stimulating behavioral change. The scientific basis for HHA/HRA risk predictions is problematic, but their arithmetic imprecision is of less concern than insufficiency of the scientific evidence for certain behavioral recommendations, and inaccuracies in client-supplied data. Widely-held beliefs in HHA/HRA's efficacy for motivating behavioral change cannot be substantiated from available evidence, nor can the assumed absence of adverse effects. The importance of this particular health promotion technique appears to have been exaggerated. PMID:7065313
High temperature, harsh environment sensors for advanced power generation systems
NASA Astrophysics Data System (ADS)
Ohodnicki, P. R.; Credle, S.; Buric, M.; Lewis, R.; Seachman, S.
2015-05-01
One mission of the Crosscutting Technology Research program at the National Energy Technology Laboratory is to develop a suite of sensors and controls technologies that will ultimately increase efficiencies of existing fossil-fuel fired power plants and enable a new generation of more efficient and lower emission power generation technologies. The program seeks to accomplish this mission through soliciting, managing, and monitoring a broad range of projects both internal and external to the laboratory which span sensor material and device development, energy harvesting and wireless telemetry methodologies, and advanced controls algorithms and approaches. A particular emphasis is placed upon harsh environment sensing for compatibility with high temperature, erosive, corrosive, and highly reducing or oxidizing environments associated with large-scale centralized power generation. An overview of the full sensors and controls portfolio is presented and a selected set of current and recent research successes and on-going projects are highlighted. A more detailed emphasis will be placed on an overview of the current research thrusts and successes of the in-house sensor material and device research efforts that have been established to support the program.
Simulation training tools for nonlethal weapons using gaming environments
NASA Astrophysics Data System (ADS)
Donne, Alexsana; Eagan, Justin; Tse, Gabriel; Vanderslice, Tom; Woods, Jerry
2006-05-01
Modern simulation techniques have a growing role for evaluating new technologies and for developing cost-effective training programs. A mission simulator facilitates the productive exchange of ideas by demonstration of concepts through compellingly realistic computer simulation. Revolutionary advances in 3D simulation technology have made it possible for desktop computers to process strikingly realistic and complex interactions with results depicted in real-time. Computer games now allow for multiple real human players and "artificially intelligent" (AI) simulated robots to play together. Advances in computer processing power have compensated for the inherent intensive calculations required for complex simulation scenarios. The main components of the leading game-engines have been released for user modifications, enabling game enthusiasts and amateur programmers to advance the state-of-the-art in AI and computer simulation technologies. It is now possible to simulate sophisticated and realistic conflict situations in order to evaluate the impact of non-lethal devices as well as conflict resolution procedures using such devices. Simulations can reduce training costs as end users: learn what a device does and doesn't do prior to use, understand responses to the device prior to deployment, determine if the device is appropriate for their situational responses, and train with new devices and techniques before purchasing hardware. This paper will present the status of SARA's mission simulation development activities, based on the Half-Life gameengine, for the purpose of evaluating the latest non-lethal weapon devices, and for developing training tools for such devices.
Concurrent simulation of a parallel jaw end effector
NASA Technical Reports Server (NTRS)
Bynum, Bill
1985-01-01
A system of programs developed to aid in the design and development of the command/response protocol between a parallel jaw end effector and the strategic planner program controlling it are presented. The system executes concurrently with the LISP controlling program to generate a graphical image of the end effector that moves in approximately real time in response to commands sent from the controlling program. Concurrent execution of the simulation program is useful for revealing flaws in the communication command structure arising from the asynchronous nature of the message traffic between the end effector and the strategic planner. Software simulation helps to minimize the number of hardware changes necessary to the microprocessor driving the end effector because of changes in the communication protocol. The simulation of other actuator devices can be easily incorporated into the system of programs by using the underlying support that was developed for the concurrent execution of the simulation process and the communication between it and the controlling program.
75 FR 26941 - Information Collection; Submission for OMB Review, Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-13
... Development, and Training grants to the Office of Management and Budget (OMB) for review and approval in... telecommunications device for the deaf (TTY-TDD) may call (202) 565-2799 between 8:30 a.m. and 5 p.m. eastern time... AmeriCorps Application Instructions: Administrative, Program Development, and Training grants. State...
Testing electroexplosive devices by programmed pulsing techniques
NASA Technical Reports Server (NTRS)
Rosenthal, L. A.; Menichelli, V. J.
1976-01-01
A novel method for testing electroexplosive devices is proposed wherein capacitor discharge pulses, with increasing energy in a step-wise fashion, are delivered to the device under test. The size of the energy increment can be programmed so that firing takes place after many, or after only a few, steps. The testing cycle is automatically terminated upon firing. An energy-firing contour relating the energy required to the programmed step size describes the single-pulse firing energy and the possible sensitization or desensitization of the explosive device.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-14
..., battery powered device with a semiconductor sensor. (2) Alcohol Countermeasure Systems Corp., submitted...-0062] Highway Safety Programs; Conforming Products List of Screening Devices To Measure Alcohol in... Screening Devices to Measure Alcohol in Bodily Fluids dated, March 31, 2008 (73 FR 16956). DATES: Effective...
7 CFR 1430.220 - Misrepresentation and scheme or device.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 7 Agriculture 10 2012-01-01 2012-01-01 false Misrepresentation and scheme or device. 1430.220... Contract Program § 1430.220 Misrepresentation and scheme or device. (a) A dairy operation shall be ineligible for the MILC program if FSA determines that it knowingly: (1) Adopted a scheme or device that...
7 CFR 1430.507 - Misrepresentation and scheme or device.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 7 Agriculture 10 2013-01-01 2013-01-01 false Misrepresentation and scheme or device. 1430.507... Assistance Program § 1430.507 Misrepresentation and scheme or device. (a) A dairy operation shall be... committee to have: (1) Adopted any scheme or device which tends to defeat the purpose of this program; (2...
7 CFR 1430.220 - Misrepresentation and scheme or device.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 7 Agriculture 10 2013-01-01 2013-01-01 false Misrepresentation and scheme or device. 1430.220... Contract Program § 1430.220 Misrepresentation and scheme or device. (a) A dairy operation shall be ineligible for the MILC program if FSA determines that it knowingly: (1) Adopted a scheme or device that...
7 CFR 1430.220 - Misrepresentation and scheme or device.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 7 Agriculture 10 2014-01-01 2014-01-01 false Misrepresentation and scheme or device. 1430.220... Contract Program § 1430.220 Misrepresentation and scheme or device. (a) A dairy operation shall be ineligible for the MILC program if FSA determines that it knowingly: (1) Adopted a scheme or device that...
7 CFR 1430.220 - Misrepresentation and scheme or device.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 10 2010-01-01 2010-01-01 false Misrepresentation and scheme or device. 1430.220... Contract Program § 1430.220 Misrepresentation and scheme or device. (a) A dairy operation shall be ineligible for the MILC program if FSA determines that it knowingly: (1) Adopted a scheme or device that...
7 CFR 1491.32 - Scheme or device.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 7 Agriculture 10 2012-01-01 2012-01-01 false Scheme or device. 1491.32 Section 1491.32 Agriculture... AGRICULTURE EXPORT PROGRAMS FARM AND RANCH LANDS PROTECTION PROGRAM General Administration § 1491.32 Scheme or device. (a) If it is determined by NRCS that a eligible entity has employed a scheme or device to defeat...
7 CFR 1413.110 - Misrepresentation and scheme or device.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 7 Agriculture 10 2012-01-01 2012-01-01 false Misrepresentation and scheme or device. 1413.110... PROGRAMS Durum Wheat Quality Program § 1413.110 Misrepresentation and scheme or device. (a) In addition to... the DWQP if the producer is determined by CCC to have: (1) Adopted any scheme or device that tends to...
7 CFR 1430.507 - Misrepresentation and scheme or device.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 7 Agriculture 10 2014-01-01 2014-01-01 false Misrepresentation and scheme or device. 1430.507... Assistance Program § 1430.507 Misrepresentation and scheme or device. (a) A dairy operation shall be... committee to have: (1) Adopted any scheme or device which tends to defeat the purpose of this program; (2...
7 CFR 1413.110 - Misrepresentation and scheme or device.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 7 Agriculture 10 2014-01-01 2014-01-01 false Misrepresentation and scheme or device. 1413.110... PROGRAMS Durum Wheat Quality Program § 1413.110 Misrepresentation and scheme or device. (a) In addition to... the DWQP if the producer is determined by CCC to have: (1) Adopted any scheme or device that tends to...
7 CFR 1430.507 - Misrepresentation and scheme or device.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 7 Agriculture 10 2012-01-01 2012-01-01 false Misrepresentation and scheme or device. 1430.507... Assistance Program § 1430.507 Misrepresentation and scheme or device. (a) A dairy operation shall be... committee to have: (1) Adopted any scheme or device which tends to defeat the purpose of this program; (2...
7 CFR 1491.32 - Scheme or device.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 7 Agriculture 10 2014-01-01 2014-01-01 false Scheme or device. 1491.32 Section 1491.32 Agriculture... AGRICULTURE EXPORT PROGRAMS FARM AND RANCH LANDS PROTECTION PROGRAM General Administration § 1491.32 Scheme or device. (a) If it is determined by NRCS that a eligible entity has employed a scheme or device to defeat...
7 CFR 1429.111 - Misrepresentation and scheme or device.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 7 Agriculture 10 2013-01-01 2013-01-01 false Misrepresentation and scheme or device. 1429.111... ASSISTANCE PAYMENT PROGRAM § 1429.111 Misrepresentation and scheme or device. (a) In addition to other... determined by CCC to have: (1) Adopted any scheme or device that tends to defeat the purpose of this program...
7 CFR 1429.111 - Misrepresentation and scheme or device.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 7 Agriculture 10 2012-01-01 2012-01-01 false Misrepresentation and scheme or device. 1429.111... ASSISTANCE PAYMENT PROGRAM § 1429.111 Misrepresentation and scheme or device. (a) In addition to other... determined by CCC to have: (1) Adopted any scheme or device that tends to defeat the purpose of this program...
7 CFR 1413.110 - Misrepresentation and scheme or device.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 7 Agriculture 10 2013-01-01 2013-01-01 false Misrepresentation and scheme or device. 1413.110... PROGRAMS Durum Wheat Quality Program § 1413.110 Misrepresentation and scheme or device. (a) In addition to... the DWQP if the producer is determined by CCC to have: (1) Adopted any scheme or device that tends to...
7 CFR 1430.507 - Misrepresentation and scheme or device.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 10 2010-01-01 2010-01-01 false Misrepresentation and scheme or device. 1430.507... Assistance Program § 1430.507 Misrepresentation and scheme or device. (a) A dairy operation shall be... committee to have: (1) Adopted any scheme or device which tends to defeat the purpose of this program; (2...
7 CFR 1491.32 - Scheme or device.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 7 Agriculture 10 2013-01-01 2013-01-01 false Scheme or device. 1491.32 Section 1491.32 Agriculture... AGRICULTURE EXPORT PROGRAMS FARM AND RANCH LANDS PROTECTION PROGRAM General Administration § 1491.32 Scheme or device. (a) If it is determined by NRCS that a eligible entity has employed a scheme or device to defeat...
7 CFR 1413.110 - Misrepresentation and scheme or device.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 7 Agriculture 10 2011-01-01 2011-01-01 false Misrepresentation and scheme or device. 1413.110... PROGRAMS Durum Wheat Quality Program § 1413.110 Misrepresentation and scheme or device. (a) In addition to... the DWQP if the producer is determined by CCC to have: (1) Adopted any scheme or device that tends to...
7 CFR 1429.111 - Misrepresentation and scheme or device.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 7 Agriculture 10 2014-01-01 2014-01-01 false Misrepresentation and scheme or device. 1429.111... ASSISTANCE PAYMENT PROGRAM § 1429.111 Misrepresentation and scheme or device. (a) In addition to other... determined by CCC to have: (1) Adopted any scheme or device that tends to defeat the purpose of this program...
7 CFR 1430.220 - Misrepresentation and scheme or device.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 7 Agriculture 10 2011-01-01 2011-01-01 false Misrepresentation and scheme or device. 1430.220... Contract Program § 1430.220 Misrepresentation and scheme or device. (a) A dairy operation shall be ineligible for the MILC program if FSA determines that it knowingly: (1) Adopted a scheme or device that...
7 CFR 1430.507 - Misrepresentation and scheme or device.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 7 Agriculture 10 2011-01-01 2011-01-01 false Misrepresentation and scheme or device. 1430.507... Assistance Program § 1430.507 Misrepresentation and scheme or device. (a) A dairy operation shall be... committee to have: (1) Adopted any scheme or device which tends to defeat the purpose of this program; (2...
Kelley, Frances J; Klopf, Maria Ignacia
2008-10-01
To describe the Clinical Communication Program developed to integrate second language learning (L2), multimedia, Web-based technologies, and the Internet in an advanced practice nursing education program. Electronic recording devices as well as audio, video editing, Web design, and programming software were used as tools for developing L2 scenarios for practice in clinical settings. The Clinical Communication Program offers opportunities to support both students and faculty members to develop their linguistic and cultural competence skills to serve better their patients, in general, and their students who speak a language other than English, in particular. The program provided 24 h on-demand access for using audio, video, and text exercises via the Internet. L2 education for healthcare providers includes linguistic (listening, speaking, reading, and writing) experiences as well as cultural competence and practices inside and outside the classroom environment as well as online and offline the Internet realm.
NASA Johnson Space Center SBIR STTR Program Technology Innovations
NASA Technical Reports Server (NTRS)
Krishen, Kumar
2007-01-01
The Small Business Innovation Research (SBIR) Program increases opportunities for small businesses to participate in research and development (R&D), increases employment, and improves U.S. competitiveness. Specifically the program stimulates U.S. technological innovation by using small businesses to meet federal R&D needs, increasing private-sector commercialization of innovations derived from federal R&D, and fostering and encouraging the participation of socially disadvantaged businesses. In 2000, the Small Business Technology Transfer (STTR) Program extended and strengthened the SBIR Program, increasing its emphasis on pursuing commercial applications by awarding contracts to small business concerns for cooperative R&D with a nonprofit research institution. Modeled after the SBIR Program, STTR is nevertheless a separately funded activity. Technologies that have resulted from the Johnson Space Center SBIR STTR Program include: a device for regenerating iodinated resin beds; laser-assisted in-situ keratomileusis or LASIK; a miniature physiological monitoring device capable of collecting and analyzing a multitude of real-time signals to transmit medical data from remote locations to medical centers for diagnosis and intervention; a new thermal management system for fibers and fabrics giving rise to new line of garments and thermal-enhancing environments; and a highly electropositive material that attracts and retains electronegative particles in water.
Air Revitalization System Enables Excursions to the Stratosphere
NASA Technical Reports Server (NTRS)
2015-01-01
Paragon Space Development Corporation, based in Tucson, Arizona has had a long history of collaboration with NASA, including developing a modular air purification system under the Commercial Crew Development Program, designed to support the commercial space sector. Using that device and other NASA technology, startup company World View is now gearing up to take customers on helium balloon rides to the stratosphere.
The Apollo spacecraft: A chronology. Volume 2: 8 November 1962 - 30 September 1964
NASA Technical Reports Server (NTRS)
Morse, M. L.; Bays, J. K.
1973-01-01
A chronology of the Apollo spacecraft development and production program is presented. The subjects discussed are: (1) defining contractural relations, (2) developing hardware distinctions, and (3) developing software ground rules. Illustrations, drawings, and photographs are used extensively to supplement the technical writing. Descriptions of life support systems, communication equipment, propulsion systems, control devices, and spacecraft components are provided.
Phototransistors Development and their Applications to Lidar
NASA Technical Reports Server (NTRS)
Abedin, M. N.; Refaat, Tamer F.; Ismail, Syed; Singh, Upendra N.
2007-01-01
Custom-designed two-micron phototransistors have been developed using Liquid Phase Epitaxy (LPE), Molecular Beam Epitaxy (MBE) and Metal-Organic Chemical Vapor Deposition (MOCVD) techniques under Laser Risk Reduction Program (LRRP). The devices were characterized in the Detector Characterization Laboratory at NASA Langley Research Center. It appears that the performance of LPE- and MBE-grown phototransistors such as responsivity, noise-equivalent-power, and gain, are better than MOCVD-grown devices. Lidar tests have been conducted using LPE and MBE devices under the 2-micrometer CO2 Differential Absorption Lidar (DIAL) Instrument Incubator Program (IIP) at the National Center for Atmospheric Research (NCAR), Boulder, Colorado. The main focus of these tests was to examine the phototransistors performances as compared to commercial InGaAs avalanche photodiode by integrating them into the Raman-shifted Eye-safe Aerosol Lidar (REAL) operating at 1.543 micrometers. A simultaneous measurement of the atmospheric backscatter signals using the LPE phototransistors and the commercial APD demonstrated good agreement between these two devices. On the other hand, simultaneous detection of lidar backscatter signals using MBE-grown phototransistor and InGaAs APD, showed a general agreement between these two devices with a lower performance than LPE devices. These custom-built phototransistors were optimized for detection around 2-micrometer wavelength while the lidar tests were performed at 1.543 micrometers. Phototransistor operation at 2-micron will improve the performance of a lidar system operating at that wavelength. Measurements include detecting hard targets (Rocky Mountains), atmospheric structure consisting of cirrus clouds and boundary layer. These phototransistors may have potential for high sensitivity differential absorption lidar measurements of carbon dioxide and water vapor at 2.05-micrometers and 1.9-micrometers, respectively.
Teaching Machines and Programmed Instruction.
ERIC Educational Resources Information Center
Kay, Harry; And Others
The various devices used in programed instruction range from the simple linear programed book to branching and skip branching programs, adaptive teaching machines, and even complex computer based systems. In order to provide a background for the would-be programer, the essential principles of each of these devices is outlined. Different ideas of…
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-23
...] Pilot Program for Early Feasibility Study Investigational Device Exemption Applications; Extending the... 13343), FDA terminated the acceptance of applications into the program and extended the pilot program for the nine accepted sponsors until May 8, 2013. The pilot program will be further extended for the...
Superconducting magnet development for tokamaks and mirrors: a technical assessment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Laverick, C.; Jacobs, R. B.; Boom, R. W.
1977-11-01
The role of superconducting magnets in Magnetic Fusion Energy Research and Development is assessed from a consideration of program plans and schedules, the present status of the programs and the research and development suggestions arising from recent studies and workshops. A principal conclusion is that the large superconducting magnet systems needed for commercial magnetic fusion reactors can be constructed. However such magnets working under severe conditions, with increasingly stringent reliability, safety and cost restrictions can never be built unless experience is first gained in a number of important installations designed to prove physics and technology steps on the way tomore » commercial power demonstration. The immediate problem is to design a technology program in the absence of definite device needs and specifications, giving a priority weighting to the multiplicity of good, high quality development program suggestions when all proposals cannot be supported.« less
Semiconductor millimeter wavelength electronics
NASA Astrophysics Data System (ADS)
Rosenbaum, F. J.
1985-12-01
This final report summarizes the results of research carried out on topics in millimeter wavelength semiconductor electronics under an ONR Selected Research Opportunity program. Study areas included III-V compound semiconductor growth and characterization, microwave and millimeter wave device modeling, fabrication and testing, and the development of new device concepts. A new millimeter wave mixer and detector, the Gap diode was invented. Topics reported on include ballistic transport, Zener oscillations, impurities in GaAs, electron velocity-electric field calculation and measurements, etc., calculations.
Analysis of a membrane-based condesate recovery heat exchanger (CRX)
NASA Technical Reports Server (NTRS)
Newbold, D.D.
1993-01-01
The development of a temperature and humidity control system that can remove heat and recover water vapor is key to the development of an Environmental Control and Life Support System (ECLSS). Large quantities of water vapor must be removed from air, and this operation has proven difficult in the absense of gravity. This paper presents the modeling results from a program to develop a novel membrane-based heat exchanger known as the condensate recovery heat exchanger (CRX). This device cools and dehumidifies humid air and simultaneously recovers water-vapor condensate. In this paper, the CRX is described and the results of an analysis of the heat- and mass-transfer characteristics of the device are given.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stokes, David
This program seeks to demonstrate a solution to enhance existing biomass cookstove performance through the use of RTI’s Thermoelectric Enhanced Cookstove Add-on (TECA) device. The self-powered TECA device captures a portion of heat from the stove and converts it to electricity through a thermoelectric (TE) device to power a blower. Colorado State University and Envirofit International are partners to support the air injection design and commercialization to enhance combustion in the stove and reduce emissions. Relevance: By demonstrating a proof of concept of the approach with the Envirofit M-5000 stove and TECA device, we hope to apply this technology tomore » existing stoves that are already in use and reduce emissions for stoves that have already found user acceptance to provide a true health benefit. Challenges: The technical challenges include achieving Tier 4 emissions from a biomass stove and for such a stove to operate reliably in the harsh field environment. Additional challenges include the fact that it is difficult to develop a cost effective solution and insure adoption and proper use in the field. Outcomes: In this program we have demonstrated PM emissions at 82 mg/MJd, a 70% reduction as compared to baseline stove operation. We have also developed a stove optimization approach that reduces the number of costly experiments. We have evaluated component-level reliability and will be testing the stove prototype in the field for performance and reliability.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dory, R.A.; Uckan, N.A.; Ard, W.B.
The ELMO Bumpy Square (EBS) concept consists of four straight magnetic mirror arrays linked by four high-field corner coils. Extensive calculations show that this configuration offers major improvements over the ELMO Bumpy Torus (EBT) in particle confinement, heating, transport, ring production, and stability. The components of the EBT device at Oak Ridge National Laboratory can be reconfigured into a square arrangement having straight sides composed of EBT coils, with new microwave cavities and high-field corners designed and built for this application. The elimination of neoclassical convection, identified as the dominant mechanism for the limited confinement in EBT, will give themore » EBS device substantially improved confinement and the flexibility to explore the concepts that produce this improvement. The primary goals of the EBS program are twofold: first, to improve the physics of confinement in toroidal systems by developing the concepts of plasma stabilization using the effects of energetic electrons and confinement optimization using magnetic field shaping and electrostatic potential control to limit particle drift, and second, to develop bumpy toroid devices as attractive candidates for fusion reactors. This report presents a brief review of the physics analyses that support the EBS concept, discussions of the design and expected performance of the EBS device, a description of the EBS experimental program, and a review of the reactor potential of bumpy toroid configurations. Detailed information is presented in the appendices.« less
(Handicap opportunities and programs in employment). Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Moon, J.P.C.
1980-01-01
Passive solar windowbox heaters were constructed by handicapped individuals and displayed in Vermont public buildings. The training enables the majority of the participants to qualify for other employment using skills developed during planning and constructing the devices. (PSB)
Recommendations and Privacy Requirements for a Bring-Your-Own-Device User Policy and Agreement
2015-03-01
manipulate data from non-traditional workplaces to support mission requirements. The United States Marine Corps (USMC) has started a pilot BYOD program, but...contrasted to obtain a starting point to develop a user agreement for the USMC. The security controls identified within these case studies were also...participating in a BYOD program. A. MARINE CORPS PILOT PROGRAM Starting in January 2015 and at the behest of the USMC, the Marine Corps Network Operations and
1981-05-01
represented as a Winkler foundation. The program can treat any number of slabs connected by steel bars or other load trans- fer devices at the joints...dimensional finite element method. The inherent flexibility of such an approach permits the analysis of a rigid pavement with steel bars and stabilized...layers and provides an efficient tool for analyzing stress conditions at the joint. Unfor- tunately, such a procedure would require a tremendously
Sahu, S K; Cockrem, J F; Parkinson, T J; Laven, R A
2017-08-01
The aim of this research was to study the roles of the day 0 energy balance and gonadotrophin-releasing hormone (GnRH) and progesterone levels on dominant follicle (DF) and corpus luteum (CL) development during the first 7 days of a gonadotrophin-prostaglandin-gonadotrophin (GPG) + progesterone (P4) program in anoestrous dairy cows. Cows (n = 81) were allocated to one of the three treatments: (1) GPG + P4 (days 0 and 9, 100 µg GnRH; day 0-7, intravaginal P4 device; day 7, 500 µg PGF 2α ); (2) GPG (as for treatment 1 but excluding the P4 device) and (3) prostaglandin + GnRH + P4 (as for treatment 1, but excluding day 0 GnRH). DF and CL size, plasma concentrations of insulin, insulin-like growth factor-I (IGF-I) and non-esterified fatty acid (NEFA) were measured on days 0 and 7. The proportion of cows with a CL on day 7 was significantly different between groups (GPG: 78%, GPG+P4: 69%, PGF 2α + GnRH + P4: 42%, P = 0.02). The CL volume on day 7 was significantly associated with treatment, treatment by time postpartum and plasma concentrations of insulin, IGF-I and NEFA. In cows without a CL present on day 0 of an oestrus synchronisation program, removal of the day 0 GnRH treatment led to reduced CL development; however, no effect of adding progesterone was found. In contrast, in cows with a CL present on day 0 inclusion of a progesterone device led to a higher CL volume, but removal of the first GnRH injection had no effect. Response to the treatment was affected by plasma concentrations of insulin, IGF-I and NEFA. © 2017 Australian Veterinary Association.
U.S. Department of Energy Reference Model Program RM1: Experimental Results.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hill, Craig; Neary, Vincent Sinclair; Gunawan, Budi
The Reference Model Project (RMP), sponsored by the U.S. Department of Energy’s (DOE) Wind and Water Power Technologies Program within the Office of Energy Efficiency & Renewable Energy (EERE), aims at expediting industry growth and efficiency by providing nonproprietary Reference Models (RM) of MHK technology designs as study objects for opensource research and development (Neary et al. 2014a,b). As part of this program, MHK turbine models were tested in a large open channel facility at the University of Minnesota’s St. Anthony Falls Laboratory (UMN-SAFL). Reference Model 1 (RM1) is a 1:40 geometric scale dual-rotor axial flow horizontal axis device withmore » counter-rotating rotors, each with a rotor diameter dT = 0.5m. Precise blade angular position and torque measurements were synchronized with three acoustic Doppler velocimeters (ADVs) aligned with each rotor and the midpoint for RM1. Flow conditions for each case were controlled such that depth, h = 1m, and volumetric flow rate, Qw = 2.425m3s-1, resulting in a hub height velocity of approximately Uhub = 1.05ms-1 and blade chord length Reynolds numbers of Rec ≈ 3.0x105. Vertical velocity profiles collected in the wake of each device from 1 to 10 rotor diameters are used to estimate the velocity recovery and turbulent characteristics in the wake, as well as the interaction of the counter-rotating rotor wakes. The development of this high resolution laboratory investigation provides a robust dataset that enables assessing turbulence performance models and their ability to accurately predict device performance metrics, including computational fluid dynamics (CFD) models that can be used to predict turbulent inflow environments, reproduce wake velocity deficit, recovery and higher order turbulent statistics, as well as device performance metrics.« less
Branch-Elliman, Westyn
2017-08-16
Cardiovascular implantable electronic device (CIED) infections are highly morbid, common, and costly, and rates are increasing (Sohail et al. Arch Intern Med 171(20):1821-8 2011; Voigt et al. J Am Coll Cardiol 48(3):590-1 2006). Factors that contribute to the development of CIED infections include patient factors (comorbid conditions, self-care, microbiome), procedural details (repeat procedure, contamination during procedure, appropriate pre-procedural prep, and antimicrobial use), environmental and organizational factors (patient safety culture, facility barriers, such as lack of space to store essential supplies, quality of environmental cleaning), and microbial factors (type of organism, virulence of organism). Each of these can be specifically targeted with infection prevention interventions. Basic prevention practices, such as administration of systemic antimicrobials prior to incision and delaying the procedure in the setting of fever or elevated INR, are helpful for day-to-day prevention of cardiac device infections. Small single-center studies provide proof-of-concept that bundled prevention interventions can reduce infections, particularly in outbreak settings. However, data regarding which prevention strategies are the most important is limited as are data regarding the optimal prevention program for day-to-day prevention (Borer et al. Infect Control Hosp Epidemiol 25(6):492-7 2004; Ahsan et al. Europace 16(10):1482-9 2014). Evolution of infection prevention programs to include ambulatory and procedural areas is crucial as healthcare delivery is increasingly provided outside of hospitals and operating rooms. The focus on traditional operating rooms and inpatient care leaves the vast majority of healthcare delivery-including cardiac device implantations in the electrophysiology laboratory-uncovered.
Smart Material Demonstrators Based on Shape Memory Alloys and Electroceramics
NASA Technical Reports Server (NTRS)
Cooke, Arther V.
1996-01-01
This paper describes the development and characterization of two technology demonstrators that were produced under the auspices of an ARPA sponsored smart materials synthesis and processing effort. The ARPA Smart Materials and Synthesis (SMS) Program was a 2 year, $10M partnership led by Martin Marietta Laboratories - Baltimore and included Lockheed Missiles & Space Co., NRL, AVX Corp., Martin Marietta Astronautics Groups, BDM Federal, Inc., Virginia Tech, Clemson, University of Maryland, Denver University, and The Johns Hopkins University. In order to demonstrate the usefulness of magnetron sputtered shape memory foil and the manufacturability of reliable, reproducible electrostrictive actuators, the team designed a broadband active vibration cancellation device for suppressing the vibration load on delicate instruments and precision pointing devices mounted on orbiting satellites and spacecraft. The results of extensive device characterization and bench testing are discussed. Initial simulation results show excellent control authority and amplitude attenuation over the range of anticipated disturbance frequencies. The SMS Team has also developed an active 1-3 composite comprising micro-electrostrictive actuators embedded in a polymeric matrix suitable for underwater applications such as sonar quieting and listening arrays, and for medical imaging. Follow-on programs employing these technologies are also described.
Acceptance of E-Learning Devices by Dental Students
Sagheb, Keyvan; Affeldt, Harald; Klumpp, Hannah; Taylor, Kathy; Walter, Christian; Al-Nawas, Bilal
2013-01-01
Background E-Learning programs and their corresponding devices are increasingly employed to educate dental students during their clinical training. Objective Recent progress made in the development of e-learning software as well as in hardware (computers, tablet PCs, smartphones) caused us to more closely investigate into the habits of dental students in dealing with these learning techniques. Methods Dental students during their clinical training attended a survey compiled in cooperation with biostatisticians. The questionnaire probands were asked to complete based on previous surveys of similar subjects, allowing single as well as multiple answers. The data, which were obtained with respect to the learning devices students commonly employ, were compared with their internet learning activities. Results The e-learning devices utilized are of heterogeneous brands. Each student has access to at least one hardware type suitable for e-learning. All students held mobile devices, about 90 percent employed laptops, and about 60 percent possess smartphones. Unexceptional all participants of the survey acknowledged an unlimited internet access. In contrast, only 16 percent of students utilized tablet PCs. A detailed analysis of the survey outcome reveals that an increasing use of mobile devices (tablet PC, smartphone) facilitates internet learning activities while at the same time utilization of computers (desktop, laptop) declines. Conclusions Dental students overwhelmingly accept e-learning during their clinical training. Students report outstanding preconditions to conduct e-learning as both their access to hardware and to the internet is excellent. Less satisfying is the outcome of our survey regarding the utilization of e-learning programs. Depending of the hardware employed only one-third to barely one-half of students comprise learning programs. PMID:25075241
Sensor and tracking data integration into a common operating picture
NASA Astrophysics Data System (ADS)
Bailey, Mark E.
2003-09-01
With rapid technological developments, a new innovative range of possibilities can be actualized in mainstreaming a network with checks and balances to provide sensor and tracking data integration/information to a wider Department of Defense (DoD) audience or group of agencies. As technologies are developed, methods to display the data are required. Multiple diverse tracking devices and sensors need to be displayed on a common operating picture. Sensors and tracking devices are used to monitor an area or object for movement or boundary penetration. Tracking devices in turn determine transit patterns of humans, animals and/or vehicles. In consortium these devices can have dual applications for military requirements and for other general purposes. The DoD Counterdrug Technology Development Program Office (CDTDPO) has designed a system to distribute sensor and tracking data to multiple users in separate agencies. This information can be displayed in whole or in part as to the specific needs of the user. It is with this purpose that the Data Distribution Network (DDN) was created to disseminate information to a collective group or to a select audience.
Advanced physical-chemical life support systems research
NASA Technical Reports Server (NTRS)
Evanich, Peggy L.
1988-01-01
A proposed NASA space research and technology development program will provide adequate data for designing closed loop life support systems for long-duration manned space missions. This program, referred to as the Pathfinder Physical-Chemical Closed Loop Life Support Program, is to identify and develop critical chemical engineering technologies for the closure of air and water loops within the spacecraft, surface habitats or mobility devices. Computerized simulation can be used both as a research and management tool. Validated models will guide the selection of the best known applicable processes and in the development of new processes. For the integration of the habitat system, a biological subsystem would be introduced to provide food production and to enhance the physical-chemical life support functions on an ever-increasing basis.
NASA Technical Reports Server (NTRS)
Ozsoy, T.; Ochs, J. B.
1984-01-01
The development of a general link between three dimensional wire frame models and rigid solid models is discussed. An interactive computer graphics program was developed to serve as a front end to an algorithm (COSMIC Program No. ARC-11446) which offers a general solution to the hidden line problem where the input data is either line segments of n-sided planar polygons of the most general type with internal boundaries. The program provides a general interface to CAD/CAM data bases and is implemented for models created on the Unigraphics VAX 11/780-based CAD/CAM systems with the display software written for DEC's VS11 color graphics devices.
Design optimization of beta- and photovoltaic conversion devices
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wichner, R.; Blum, A.; Fischer-Colbrie, E.
1976-01-08
This report presents the theoretical and experimental results of an LLL Electronics Engineering research program aimed at optimizing the design and electronic-material parameters of beta- and photovoltaic p-n junction conversion devices. To meet this objective, a comprehensive computer code has been developed that can handle a broad range of practical conditions. The physical model upon which the code is based is described first. Then, an example is given of a set of optimization calculations along with the resulting optimized efficiencies for silicon (Si) and gallium-arsenide (GaAs) devices. The model we have developed, however, is not limited to these materials. Itmore » can handle any appropriate material--single or polycrystalline-- provided energy absorption and electron-transport data are available. To check code validity, the performance of experimental silicon p-n junction devices (produced in-house) were measured under various light intensities and spectra as well as under tritium beta irradiation. The results of these tests were then compared with predicted results based on the known or best estimated device parameters. The comparison showed very good agreement between the calculated and the measured results.« less
Advanced Design Concepts for Dense Plasma Focus Devices at LLNL
NASA Astrophysics Data System (ADS)
Povilus, Alexander; Podpaly, Yuri; Cooper, Christopher; Shaw, Brian; Chapman, Steve; Mitrani, James; Anderson, Michael; Pearson, Aric; Anaya, Enrique; Koh, Ed; Falabella, Steve; Link, Tony; Schmidt, Andrea
2017-10-01
The dense plasma focus (DPF) is a z-pinch device where a plasma sheath is accelerated down a coaxial railgun and ends in a radial implosion, pinch phase. During the pinch phase, the plasma generates intense, transient electric fields through physical mechanisms, similar to beam instabilities, that can accelerate ions in the plasma sheath to MeV-scale energies on millimeter length scales. Using kinetic modeling techniques developed at LLNL, we have gained insight into the formation of these accelerating fields and are using these observations to optimize the behavior of the generated ion beam for producing neutrons via beam-target interactions for kilojoule to megajoule-scale devices. Using a set of DPF's, both in operation and in development at LLNL, we have explored critical aspects of these devices, including plasma sheath formation behavior, power delivery to the plasma, and instability seeding during the implosion in order to improve the absolute yield and stability of the device. Prepared by LLNL under Contract DE-AC52-07NA27344. Computing support for this work came from the LLNL Institutional Computing Grand Challenge program.
Mandal, Subhamoy; Basak, Kausik; Mandana, K M; Ray, Ajoy K; Chatterjee, Jyotirmoy; Mahadevappa, Manjunatha
2011-03-01
The invention is inspired by the desire to understand the opportunities and expectations of developing economies in terms of healthcare. The designed system is a point-of-care (POC) device that can deliver heart-care services to the rural population and bridge the rural-urban divide in healthcare delivery. The product design incorporates several innovations including the effective use of adaptive and multiresolution signal-processing techniques for acquisition, denoising, segmentation, and characterization of the heart sounds (HS) and murmurs using an ultralow-power embedded Mixed Signal Processor. The device is able to provide indicative diagnosis of cardiac conditions and classify a subject into either normal, abnormal, ischemic, or valvular abnormalities category. Preliminary results demonstrated by the prototype confirm the applicability of the device as a prescreening tool that can be used by paramedics in rural outreach programs. Feedback from medical professionals also shows that such a device is helpful in early detection of common congenital heart diseases. This letter aims to determine a framework for utilization of automated HS analysis system for community healthcare and healthcare inclusion.
Preliminary Studies of Ions Emission in a Small Plasma Focus Device of Hundreds of Joules
DOE Office of Scientific and Technical Information (OSTI.GOV)
Moreno, Jose; Pavez, Cristian; Soto, Leopoldo
2009-01-21
Ion beam emission in plasma focus (PF) discharges was originally investigated to explain the strong forward anisotropy observed in the neutron. Several properties of PF emitted deuteron beams have been measured, including their angular distributions and energy spectra in devices operating with energies from 1 kJ to 1 MJ. At present there is a growing interest in the development of very small PF devices operating under 1 kJ. As part of the characterization program of the very low energy PF devices (<1 kJ) developed at the Chilean Nuclear Energy Commission, the charges particle emission in hydrogen (H{sub 2}) and mixturemore » (H{sub 2}+%Ar) are being studied. In order to obtain an estimation of the ions energy spectrum and ionization grade, by using time of flight method, a graphite collector system operating in the bias ion collector mode was constructed and it is being used. Preliminary results of the ion beams measurements in different experimental conditions, at a plasma focus device of 400 joules (PF-400 J) are presented.« less
Stretchable living materials and devices with hydrogel–elastomer hybrids hosting programmed cells
Liu, Xinyue; Tang, Tzu-Chieh; Tham, Eléonore; Yuk, Hyunwoo; Lin, Shaoting; Lu, Timothy K.; Zhao, Xuanhe
2017-01-01
Living systems, such as bacteria, yeasts, and mammalian cells, can be genetically programmed with synthetic circuits that execute sensing, computing, memory, and response functions. Integrating these functional living components into materials and devices will provide powerful tools for scientific research and enable new technological applications. However, it has been a grand challenge to maintain the viability, functionality, and safety of living components in freestanding materials and devices, which frequently undergo deformations during applications. Here, we report the design of a set of living materials and devices based on stretchable, robust, and biocompatible hydrogel–elastomer hybrids that host various types of genetically engineered bacterial cells. The hydrogel provides sustainable supplies of water and nutrients, and the elastomer is air-permeable, maintaining long-term viability and functionality of the encapsulated cells. Communication between different bacterial strains and with the environment is achieved via diffusion of molecules in the hydrogel. The high stretchability and robustness of the hydrogel–elastomer hybrids prevent leakage of cells from the living materials and devices, even under large deformations. We show functions and applications of stretchable living sensors that are responsive to multiple chemicals in a variety of form factors, including skin patches and gloves-based sensors. We further develop a quantitative model that couples transportation of signaling molecules and cellular response to aid the design of future living materials and devices. PMID:28202725
NASA Astrophysics Data System (ADS)
Romanosky, Robert R.
2017-05-01
he National Energy Technology Laboratory (NETL) under the Department of Energy (DOE) Fossil Energy (FE) Program is leading the effort to not only develop near zero emission power generation systems, but to increaser the efficiency and availability of current power systems. The overarching goal of the program is to provide clean affordable power using domestic resources. Highly efficient, low emission power systems can have extreme conditions of high temperatures up to 1600 oC, high pressures up to 600 psi, high particulate loadings, and corrosive atmospheres that require monitoring. Sensing in these harsh environments can provide key information that directly impacts process control and system reliability. The lack of suitable measurement technology serves as a driver for the innovations in harsh environment sensor development. Advancements in sensing using optical fibers are key efforts within NETL's sensor development program as these approaches offer the potential to survive and provide critical information about these processes. An overview of the sensor development supported by the National Energy Technology Laboratory (NETL) will be given, including research in the areas of sensor materials, designs, and measurement types. New approaches to intelligent sensing, sensor placement and process control using networked sensors will be discussed as will novel approaches to fiber device design concurrent with materials development research and development in modified and coated silica and sapphire fiber based sensors. The use of these sensors for both single point and distributed measurements of temperature, pressure, strain, and a select suite of gases will be addressed. Additional areas of research includes novel control architecture and communication frameworks, device integration for distributed sensing, and imaging and other novel approaches to monitoring and controlling advanced processes. The close coupling of the sensor program with process modeling and control will be discussed for the overarching goal of clean power production.
Development of an inherently digital transducer
NASA Technical Reports Server (NTRS)
Richard, R. R.
1972-01-01
The term digital transducer normally implies the combination of conventional analog sensors with encoders or analog-to-digital converters. Because of the objectionable characteristics of most digital transducers, a program was instituted to investigate the possibility of producing a transducer that is inherently digital, instead of a transducer that is digital in the usual sense. Such a device would have improved accuracy and reliability and would have reduced power and bulk requirements because two processes, sensing and conditioning, would be combined into one processes. A Curie-point-temperature sensor is described that represents realization of the stated goal. Also, a metal-insulator semiconductor is described that does not conform precisely to the program goals but that appears to have applications as a new and interesting transduction device.
A Low Cost Mechatronics Device for STEM Education
NASA Astrophysics Data System (ADS)
Himes, Larry Eugene, Jr.
All of the low-cost STEM education devices currently available are limited in function which limits learning. The motivation was to design and develop a device that will intrigue post-secondary students to learn STEM education concepts in a hands-on manner. The device needed to be open source so as to lower the cost to make it available to more students. And, making it feature rich was important for use with multiple projects the students may encounter or build themselves as they grow. The device has provided visual and physical feedback to students making the device more intriguing to use. Using the open-source C compiler reduced cost for students to use the device and taught them how to use an industry standard programming language. Students enjoyed the WAV file rendering for sound effects and LED lighting effects from the device. Most interviewees were intrigued by the device for use in their training facilities and classrooms. There are a couple of multi-axis controllers available but none with position feedback. Ethernet or Bluetooth interfacing was mentioned as a future feature and it was encouraged by nearly all who were interviewed.
Walker, Joshua M; Elliott, David A; Kubicky, Charlotte D; Thomas, Charles R; Naik, Arpana M
2016-01-01
Three-dimensional (3D) printing has emerged as a promising modality for the production of medical devices. Here we describe the design, production, and implementation of a series of sizing tools for use in an intraoperative breast brachytherapy program. These devices were produced using a commercially available low-cost 3D printer and software, and their implementation resulted in an immediate decrease in consumable costs without affecting the quality of care or the speed of delivery. This work illustrates the potential of 3D printing to revolutionize the field of medical devices, enabling physicians to rapidly develop and prototype novel tools.
Optical synthesizer for a large quadrant-array CCD camera: Center director's discretionary fund
NASA Technical Reports Server (NTRS)
Hagyard, Mona J.
1992-01-01
The objective of this program was to design and develop an optical device, an optical synthesizer, that focuses four contiguous quadrants of a solar image on four spatially separated CCD arrays that are part of a unique CCD camera system. This camera and the optical synthesizer will be part of the new NASA-Marshall Experimental Vector Magnetograph, and instrument developed to measure the Sun's magnetic field as accurately as present technology allows. The tasks undertaken in the program are outlined and the final detailed optical design is presented.
Developments in Radiation-Hardened Electronics Applicable to the Vision for Space Exploration
NASA Technical Reports Server (NTRS)
Keys, Andrew S.; Frazier, Donald O.; Patrick , Marshall C.; Watson, Michael D.; Johnson, Michael A.; Cressler, John D.; Kolawa, Elizabeth A.
2007-01-01
The Radiation Hardened Electronics for Space Exploration (RHESE) project develops the advanced technologies required to produce radiation hardened electronics, processors, and devices in support of the anticipated requirements of NASA's Constellation program. Methods of protecting and hardening electronics against the encountered space environment are discussed. Critical stages of a spaceflight mission that are vulnerable to radiation-induced interruptions or failures are identified. Solutions to mitigating the risk of radiation events are proposed through the infusion of RHESE technology products and deliverables into the Constellation program's spacecraft designs.
1970-01-01
This chart describes Skylab's Particle Collection device, a scientific experiment designed to study micro-meteoroid particles in near-Earth space and determine their abundance, mass distribution, composition, and erosive effects. The Marshall Space Flight Center had program management responsibility for the development of Skylab hardware and experiments.
1970-01-01
This photograph shows Skylab's Particle Collection device, a scientific experiment designed to study micro-meteoroid particles in near-Earth space and determine their abundance, mass distribution, composition, and erosive effects. The Marshall Space Flight Center had program management responsibility for the development of Skylab hardware and experiments.
Code of Federal Regulations, 2011 CFR
2011-01-01
... ENERGY ENERGY CONSERVATION ELECTRIC AND HYBRID VEHICLE RESEARCH, DEVELOPMENT, AND DEMONSTRATION PROGRAM... storage batteries or other portable electrical energy storage devices, provided that: (1) Recharge energy... electrical energy required for an electric vehicle to travel one mile of the Highway Fuel Economy Driving...
Martelli, Nicolas; van den Brink, Hélène
2014-07-01
Financing innovative medical devices is an important challenge for national health policy makers, and a crucial issue for hospitals. However, when innovative medical devices are launched on the European market there is generally little clinical evidence regarding both efficacy and safety, both because of the flaws in the European system for regulating such devices, and because they are at an early stage of development. To manage the uncertainty surrounding the reimbursement of innovation, several European countries have set up temporary funding schemes to generate evidence about the effectiveness of devices. This article explores two different French approaches to funding innovative in-hospital devices and collecting supplementary data: the coverage with evidence development (CED) scheme introduced under Article L. 165-1-1 of the French Social Security Code; and national programs for hospital-based research. We discuss pros and cons of both approaches in the light of CED policies in Germany and the UK. The CED policies for devices share common limitations. Thus, transparency of CED processes should be enhanced and decisions need to be made in a timely way. Finally, we think that closer collaboration between manufacturers, health authorities and hospitals is essential to make CED policies more operational. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Development and testing of tip devices for horizontal axis wind turbines
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gyatt, G.W.; Lissaman, P.B.S.
1985-05-01
A theoretical and field experimental program has been carried out to investigate the use of tip devices on horizontal axis wind turbine rotors. Objective was to improve performance by the reduction of tip losses. A vortex lattice computer model was used to optimize three basic tip configuration types for a 25 kW stall limited commercial wind turbines. The types were a change in tip planform, and a single-element and double-element nonplannar tip extension (winglets). Approximately 270 h of performance data were collected over a three-month period. The sampling interval was 2.4 s; thus over 400,000 raw data points were logged.more » Results for each of the three new tip devices, compared with the original tip, showed a small decrease (of the order of 1 kW) in power output over the measured range of wind speeds from cut-in at about 4 m/s to over 20 m/s, well into the stall limiting region. For aircraft wing tip devices, favorable tip shapes have been reported and it is likely that the tip devices tested in this program did not improve rotor performance because they were not optimally adjusted. The computer model used does not have adequate lifting surface resolution or accuracy to design these small winglet extensions.« less
Predictors of nurses' acceptance of an intravenous catheter safety device.
Rivers, Dianna Lipp; Aday, Lu Ann; Frankowski, Ralph F; Felknor, Sarah; White, Donna; Nichols, Brenda
2003-01-01
It is important to determine the factors that predict whether nurses accept and use a new intravenous (IV) safety device because there are approximately 800,000 needlesticks per year with the risk of contracting a life-threatening bloodborne disease such as HIV or hepatitis C. To determine the predictors of nurses' acceptance of the Protectiv Plus IV catheter safety needle device at a teaching hospital in Texas. A one-time cross-sectional survey of nurses (N = 742) was conducted using a 34-item questionnaire. A framework was developed identifying organizational and individual predictors of acceptance. The three principal dimensions of acceptance were (a) satisfaction with the device, (b) extent to which the device is always used, and (c) nurse recommendations over other safety devices. Measurements included developing summary subscales for the variables of safety climate and acceptance. Descriptive statistics and multiple linear and logistic regression models were computed. The findings showed widespread acceptance of the device. Nurses who had adequate training and a positive institutional safety climate were more accepting (p
ERIC Educational Resources Information Center
Swan, Karen; Kratcoski, Annette; Mazzer, Pat; Schenker, Jason
2005-01-01
This article describes an ongoing situated professional development program in which teachers bring their intact classes for an extended stay in a ubiquitous computing environment equipped with a variety of state-of-the-art computing devices. The experience is unique in that it not only situates teacher learning about technology integration in…
2015-10-01
Medical Research and Materiel Command Fort Detrick, Maryland 21702-5012 DISTRIBUTION STATEMENT: Approved for Public Release; Distribution Unlimited The...SPONSORING / MONITORING AGENCY NAME(S) AND ADDRESS(ES) 10. SPONSOR/MONITOR’S ACRONYM(S) U.S. Army Medical Resear ch and Materiel Command Fort Detrick...DDT) and Medical Device Development Tool (MDDT) programs with case study presentations and question and answer opportunities. Expert Working Groups
Predicting the valley physics of silicon quantum dots directly from a device layout
NASA Astrophysics Data System (ADS)
Gamble, John King; Harvey-Collard, Patrick; Jacobson, N. Tobias; Bacewski, Andrew D.; Nielsen, Erik; Montaño, Inès; Rudolph, Martin; Carroll, Malcolm S.; Muller, Richard P.
Qubits made from electrostatically-defined quantum dots in Si-based systems are excellent candidates for quantum information processing applications. However, the multi-valley structure of silicon's band structure provides additional challenges for the few-electron physics critical to qubit manipulation. Here, we present a theory for valley physics that is predictive, in that we take as input the real physical device geometry and experimental voltage operation schedule, and with minimal approximation compute the resulting valley physics. We present both effective mass theory and atomistic tight-binding calculations for two distinct metal-oxide-semiconductor (MOS) quantum dot systems, directly comparing them to experimental measurements of the valley splitting. We conclude by assessing these detailed simulations' utility for engineering desired valley physics in future devices. Sandia is a multi-program laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Corporation, for the US Department of Energy's National Nuclear Security Administration under Contract No. DE-AC04-94AL85000. The authors gratefully acknowledge support from the Sandia National Laboratories Truman Fellowship Program, which is funded by the Laboratory Directed Research and Development (LDRD) Program.
Teaching smartphone and microcontroller systems using "Android Java"
NASA Astrophysics Data System (ADS)
Tigrek, Seyitriza
Mobile devices are becoming indispensable tools for many students and educators. Mobile technology is starting a new era in the computing methodologies in many engineering disciplines and laboratories. Microcontroller extension that communicates with mobile devices will take the data acquisition and control process into a new level in the sensing technology and communication. The purpose of this thesis is to develop a framework to incorporate the new mobile platform with robust embedded systems into the engineering curriculum. For this purpose a course material is developed "Introduction to Programming Java on a Mobile Platform" to teach novice programmers how to create applications, specifically on Android. Combining an introductory level programming class with the Android platform can appeal to non-programming individuals in multiple disciplines. The proposed course curriculum reduces the learning time, and allows senior engineering students to use the new framework for their specific needs in the labs such as mobile data acquisition and control projects. This work provides techniques for instructors with modest programming background to teach cutting edge technology, which is smartphone programming. Techniques developed in this work minimize unnecessary information carried into current teaching approaches with hands-on practice. It also helps the students with minimal background requirements overcome the barriers that have evolved around computer programming. The motivation of this thesis is to create a tailored programming introductory course to teach Java programming on Android by incorporating selected efficient methods from extant literature. The mechanism proposed in this thesis is to keep students motivated by an active approach based on student-centered learning with collaborative work. Teamwork through pair programming is adapted in this teaching process. Bloom's taxonomy, along with a knowledge survey, is used as a guide to classify the information and exercise problems. A prototype curriculum is a deliverable of this research that is suitable for novice programmers-such as engineering freshmen students. It also contains advanced material that allows senior students to use mobile phone and a microcontroller system to enhance engineering laboratories.
Lubans, David R; Smith, Jordan J; Skinner, Geoff; Morgan, Philip J
2014-01-01
To describe the development and implementation of a smartphone application (app) designed to promote physical activity and reduce screen-time in adolescent boys considered "at-risk" of obesity. An app was developed to support the delivery of a face-to-face school-based obesity prevention program known as the "Active Teen Leaders Avoiding Screen-time" (ATLAS) program. ATLAS was guided by self-determination theory and social cognitive theory and evaluated using a cluster randomized controlled trial with 361 boys (12.7 ± 0.5 years) in 14 secondary schools. Following the completion of the study, participants in the intervention group completed a process evaluation questionnaire and focus groups were conducted with 42 students to explore their general perceptions of the ATLAS program and their experience with the smartphone app. Barriers and challenges encountered in the development, implementation, and evaluation of the app are also described. Participation in the study was not contingent on ownership of a smartphone, but 70% of participants in the intervention group reported having access to a smartphone or tablet device. Focus group participants reported an enjoyment of the program, and felt that it had provided them with new skills, techniques, and routines for the future. However, their engagement with the smartphone app was limited, due to a variety of reasons. Barriers to the implementation and evaluation of the app included limited access to smartphone devices, technical problems with the push notifications, lack of access to usage data, and the challenges of maintaining participants' interest in using the app. Although participants reported high levels of satisfaction with the ATLAS program in general, the smartphone app was not used extensively. Additional strategies and features may be needed to enhance engagement in adolescent boys.
NASA Astrophysics Data System (ADS)
Choe, Byeong-In; Park, Byung-Gook; Lee, Jong-Ho
2013-06-01
The program disturbance characteristic in the three-dimensional (3D) stack NAND flash was analyzed for the first time in terms of string select line (SSL) threshold voltage (Vth) and p-type body doping profile. From the edge word line (W/L) program disturbance, we can observe the boosted channel potential loss as a function of SSL Vth and body doping profile for SSL device. According to simulation work, a high Vth of the SSL device is required to suppress channel leakage during programming. When the body doping of the SSL device is high in the channel, there is a large band bending near the gate edge of the SSL adjacent to the edge W/L cell of boosted cell strings, which generates significantly electron-hole pairs. The generated electrons decreases the boosted channel potential, resulting in increase of program disturbance of the inhibit strings. Through optimization of the body doping profile of the SSL device, both channel leakage and the program disturbance are successfully suppressed for a highly reliable 3D stack NAND flash memory cell operation.
Exploratory Development on an Electronic Safing and Arming Device for Ordnance Fuzing
1983-02-01
to the bridges. Two units were subjected to MIL-STD-331, Test 101, Jolt. The EBMs were placed in the S & A cavity of an M739 fuze body for this test...of the program was to explore a concept for a safe, reliable, general purpose, low cost, electronic, A ’ zsafing and arming ( S & A ) system for use in...breadboard model hardware of the electronic S & A device. The electronic S & A devicu consists of an explosive barrier moduls (EBM) explosive train
Effectiveness of the Civil Aviation Security Program.
1982-10-26
12 IX. CIVIL AVIATION SECURITY ACTIONS . . . . . . 14 X . MPIANCE M EN4FOW . ........ 20 X . U . . . . . ... . . . . .. . . . 21 EXHIBITS 1...Screening Results 10. Weapon Detection Devices 11. X -Ray Baggage Inspection Systems 12. Basic Policies 13. Regulatory Impact 14. FAA Sponsored Explosive...WERE APPROVED FOR MORE THAN 200 AIRPORTS. D . TESTING WAS BEGUN ON A NEW C MPUTER PROGRAM FOR HE X -RAY ABSORPTION SYSTEM DEVELOPED TO DTECT BMBS IN
Night Vision Goggle Training; Development and Production of Six Video Programs
1992-11-01
SUIUECT TERMS Multimedia Video production iS. NUMBER OF PAGES Aeral photography Night vision Videodisc 18 Image Intensification Night vision goggles...reference tool on the squadron or wing demonstrates NVG field of view, field of level. The programs run approximately ten regard, scan techniques, image...training device modalities. These The production of a videodisc that modalities include didactic and video will serve as an NVG audio-visual database
A passive cold storage device economic model to evaluate selected immunization location scenarios.
Norman, Bryan A; Nourollahi, Sevnaz; Chen, Sheng-I; Brown, Shawn T; Claypool, Erin G; Connor, Diana L; Schmitz, Michelle M; Rajgopal, Jayant; Wateska, Angela R; Lee, Bruce Y
2013-10-25
The challenge of keeping vaccines cold at health posts given the unreliability of power sources in many low- and middle-income countries and the expense and maintenance requirements of solar refrigerators has motivated the development of passive cold storage devices (PCDs), containers that keep vaccines cold without using an active energy source. With different PCDs under development, manufacturers, policymakers and funders need guidance on how varying different PCD characteristics may affect the devices' cost and utility. We developed an economic spreadsheet model representing the lowest two levels of a typical Expanded Program on Immunization (EPI) vaccine supply chain: a district store, the immunization locations that the district store serves, and the transport vehicles that operate between the district store and the immunization locations. The model compares the use of three vaccine storage device options [(1) portable PCDs, (2) stationary PCDs, or (3) solar refrigerators] and allows the user to vary different device (e.g., size and cost) and scenario characteristics (e.g., catchment area population size and vaccine schedule). For a sample set of select scenarios and equipment specification, we found the portable PCD to generally be better suited to populations of 5,000 or less. The stationary PCD replenished once per month can be a robust design especially with a 35L capacity and a cost of $2,500 or less. The solar device was generally a reasonable alternative for most of the scenarios explored if the cost was $2,100 or less (including installation). No one device type dominated over all explored circumstances. Therefore, the best device may vary from country-to-country and location-to-location within a country. This study introduces a quantitative model to help guide PCD development. Although our selected set of explored scenarios and device designs was not exhaustive, future explorations can further alter model input values to represent additional scenarios and device designs. Copyright © 2013 Elsevier Ltd. All rights reserved.
78 FR 19711 - Center for Devices and Radiological Health: Experiential Learning Program
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-02
... Program (ELP). The ELP provides a formal training mechanism for regulatory review staff to visit research... medical device establishments, including, research, manufacturing, academia, and health care facilities.... Clinical use of orthopedic bone void Observation of surgical filler devices. procedures (posterolateral...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-08
...-7205 Ventricular Assist Device (Destination Therapy) Facilities. XIII Medicare-Approved Lung JoAnna...-Approved Ventricular Assist Device (Destination Therapy) Facilities, Addendum XIII: Lung Volume Reduction...-Approved Ventricular Assist Device (Destination Therapy) Facilities (January Through March 2011) Addendum...
Mechanical Circulatory Support of the Critically Ill Child Awaiting Heart Transplantation
Gazit, Avihu Z; Gandhi, Sanjiv K; C Canter, Charles
2010-01-01
The majority of children awaiting heart transplantation require inotropic support, mechanical ventilation, and/or extracorporeal membrane oxygenation (ECMO) support. Unfortunately, due to the limited pool of organs, many of these children do not survive to transplant. Mechanical circulatory support of the failing heart in pediatrics is a new and rapidly developing field world-wide. It is utilized in children with acute congestive heart failure associated with congenital heart disease, cardiomyopathy, and myocarditis, both as a bridge to transplantation and as a bridge to myocardial recovery. The current arsenal of mechanical assist devices available for children is limited to ECMO, intra-aortic balloon counterpulsation, centrifugal pump ventricular assist devices, the DeBakey ventricular assist device Child; the Thoratec ventricular assist device; and the Berlin Heart. In the spring of 2004, five contracts were awarded by the National Heart, Lung and Blood Institute to support preclinical development for a range of pediatric ventricular assist devices and similar circulatory support systems. The support of early development efforts provided by this program is expected to yield several devices that will be ready for clinical trials within the next few years. Our work reviews the current international experience with mechanical circulatory support in children and summarizes our own experience since 2005 with the Berlin Heart, comparing the indications for use, length of support, and outcome between these modalities. PMID:21286278
Bolometric Array Detectors for Space-Borne Astronomy
NASA Technical Reports Server (NTRS)
Lange, Andrew E.
2000-01-01
Funding from the NASA Innovative Research Grant was used to develop bolometric detectors. As described in the proposal, silicon nitride micromesh ('spider-web') absorbers had been demonstrated at U.C. Berkeley but not developed to be flight-worthy devices. We proceeded to first fabricate bolometers with Neutron Transmutation Doped (NTD) Ge thermistors that demonstrated high optical coupling (Church et al. 1996) and were developed for a ground-based millimeter-wave receiver (Mauskopf et al. 1997). The next generation of devices used In bump-bonded thermistors to achieve devices with performance product NEP*sqrt(tau) = 3e - 18 j at 300 mK, demonstrating a full order of magnitude improvement over pervious devices. These devices achieved an NEP = 1e-18 W/rtHz (Murray et al. 1996) as promised in the proposal. Sensitivities as good as 1e - 19 W/rtHz appear achievable with the silicon nitride architecture (Bock et al. 1997). Finally, arrays of micromesh bolometers were shown to be feasible in the last year of the program by etching a large number of devices on a single silicon wafer (75 mm). Full arrays were subsequently demonstrated for selection on the ESA/NASA Far-Infrared Space Telescope (FIRST) in competition with detectors provided by CEA in France and GSFC in the US Micromesh bolometer arrays are now baselined for both the ESA/NASA Planck and FIRST missions.
Case outsourcing medical device reprocessing.
Haley, Deborah
2004-04-01
IN THE INTEREST OF SAVING MONEY, many hospitals are considering extending the life of some single-use medical devices by using medical device reprocessing programs. FACILITIES OFTEN LACK the resources required to meet the US Food and Drug Administration's tough quality assurance standards. BY OUTSOURCING, hospitals can reap the benefits of medical device reprocessing without assuming additional staffing and compliance burdens. OUTSOURCING enables hospitals to implement a medical device reprocessing program quickly, with no capital investment and minimal effort.
Killackey, Eoin; Anda, Anna Lee; Gibbs, Martin; Alvarez-Jimenez, Mario; Thompson, Andrew; Sun, Pamela; Baksheev, Gennady N
2011-05-12
Young people with first episode psychosis are at an increased risk for a range of poor health outcomes. In contrast to the growing body of evidence that suggests that exercise therapy may benefit the physical and mental health of people diagnosed with schizophrenia, there are no studies to date that have sought to extend the use of exercise therapy among patients with first episode psychosis. The aim of the study is to test the feasibility and acceptability of an exercise program that will be delivered via internet enabled mobile devices and social networking technologies among young people with first episode psychosis. This study is a qualitative pilot study being conducted at Orygen Youth Health Research Centre in Melbourne, Australia. Participants are young people aged 15-24 who are receiving clinical care at a specialist first episode psychosis treatment centre. Participants will also comprise young people from the general population. The exercise intervention is a 9-week running program, designed to gradually build a person's level of fitness to be able to run 5 kilometres (3 miles) towards the end of the program. The program will be delivered via an internet enabled mobile device. Participants will be asked to post messages about their running experiences on the social networking website, and will also be asked to attend three face-to-face interviews. This paper describes the development of a qualitative study to pilot a running program coupled with the use of internet enabled mobile devices among young people with first episode psychosis. If the program is found to be feasible and acceptable to patients, it is hoped that further rigorous evaluations will ultimately lead to the introduction of exercise therapy as part of an evidence-based, multidisciplinary approach in routine clinical care.
A novel method of sensing temperatures of magnet coils of SINP-MaPLE plasma device
NASA Astrophysics Data System (ADS)
Pal, A. M.; Bhattacharya, S.; Biswas, S.; Basu, S.; Pal, R.
2014-03-01
A set of 36 magnet coils is used to produce a continuous, uniform magnetic field of about 0.35 Tesla inside the vacuum chamber of the MaPLE Device, a linear laboratory plasma device (3 m long and 0.30 m in diameter) built for studying basic magnetized plasma physics phenomena. To protect the water cooled-coils from serious damage due to overheating temperatures of all the coils are monitored electronically using low cost temperature sensor IC chips, a technique first being used in similar magnet system. Utilizing the Parallel Port of a Personal Computer a novel scheme is used to avoid deploying microprocessor that is associated with involved circuitry and low level programming to address and control the large number of sensors. The simple circuits and a program code to implement the idea are developed, tested and presently in operation. The whole arrangement comes out to be not only attractive, but also simple, economical and easy to install elsewhere.
A 350 MHz, 200 kW CW, Multiple Beam Inductive Output Tube - Final Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
R.Lawrece Ives; George Collins; David Marsden Michael Read
2012-11-28
This program developed a 200 kW CW, 350 MHz, multiple beam inductive output tube (MBIOT) for driving accelerator cavities. The MBIOT operates at 30 kV with a gain of 23 dB. The estimated efficiency is 70%. The device uses seven electron beams, each transmitting 1.4 A of current. The tube is approximately six feet long and weighs approximately 400 lbs. The prototype device will be evaluated as a potential RF source for the Advanced Photon Source at Argonne National Laboratory (ANL). Because of issues related to delivery of the electron guns, it was not possible to complete assembly and testmore » of the MBIOT during the Phase II program. The device is being completed with support from Calabazas Creek Research, Inc., Communications & Power Industries, LLC. and the Naval Surface Weapons Center (NSWC) in Dahlgren, VA. The MBIOT will be initially tested at NSWC before delivery to ANL. The testing at NSWC is scheduled for February 2013.« less
Defense Threat Reduction Agency Radiochemical Needs
NASA Astrophysics Data System (ADS)
Walsh, Michael A. R.; Velazquez, Daniel L.
2009-08-01
The United States Government (USG) first developed nuclear forensics-related capabilities to analyze radiological and nuclear materials, including underground nuclear test debris and interdicted materials. Nuclear forensics is not a new mission for Department of Defense (DoD). The department's existing nuclear forensics capability is the result of programs that span six (6) decades and includes activities to assess foreign nuclear weapons testing activities, monitor and verify nuclear arms control treaties, and to support intelligence and law enforcement activities. Today, nuclear forensics must support not only weapons programs and nuclear smuggling incidents, but also the scientific analysis and subsequent attribution of terrorists' use of radiological or nuclear materials/devices. Nuclear forensics can help divulge the source of origin of nuclear materials, the type of design for an interdicted or detonated device, as well as the pathway of the materials or device to the incident. To accomplish this mission, the USG will need trained radiochemists and nuclear scientists to fill new positions and replace the retiring staff.
NASA Technical Reports Server (NTRS)
Eichenberg, Dennis J.
2004-01-01
In fiscal year 2003, the continuation of the Hybrid Power Management (HPM) Program through NASA Glenn Research Center's Commercial Technology Office resulted in several new successful applications of this pioneering technology. HPM is the innovative integration of diverse, state-of-the-art power devices in an optimal configuration for space and terrestrial applications. The appropriate application and control of the various power devices significantly improves overall system performance and efficiency. The advanced power devices include ultracapacitors, fuel cells, and photovoltaics. HPM has extremely wide potential, with applications from nanowatts to megawatts--including power generation, transportation systems, biotechnology systems, and space power systems. HPM has the potential to significantly alleviate global energy concerns, improve the environment, and stimulate the economy. Fuel cells provide excellent efficiency and energy density, but do not have good power density. In contrast, ultracapacitors have excellent power density and virtually unlimited cycle life. To improve the power density of the fuel cell, the combination of fuel cells and ultracapacitors was evaluated.
Laboratory simulation of space plasma phenomena*
NASA Astrophysics Data System (ADS)
Amatucci, B.; Tejero, E. M.; Ganguli, G.; Blackwell, D.; Enloe, C. L.; Gillman, E.; Walker, D.; Gatling, G.
2017-12-01
Laboratory devices, such as the Naval Research Laboratory's Space Physics Simulation Chamber, are large-scale experiments dedicated to the creation of large-volume plasmas with parameters realistically scaled to those found in various regions of the near-Earth space plasma environment. Such devices make valuable contributions to the understanding of space plasmas by investigating phenomena under carefully controlled, reproducible conditions, allowing for the validation of theoretical models being applied to space data. By working in collaboration with in situ experimentalists to create realistic conditions scaled to those found during the observations of interest, the microphysics responsible for the observed events can be investigated in detail not possible in space. To date, numerous investigations of phenomena such as plasma waves, wave-particle interactions, and particle energization have been successfully performed in the laboratory. In addition to investigations such as plasma wave and instability studies, the laboratory devices can also make valuable contributions to the development and testing of space plasma diagnostics. One example is the plasma impedance probe developed at NRL. Originally developed as a laboratory diagnostic, the sensor has now been flown on a sounding rocket, is included on a CubeSat experiment, and will be included on the DoD Space Test Program's STP-H6 experiment on the International Space Station. In this presentation, we will describe several examples of the laboratory investigation of space plasma waves and instabilities and diagnostic development. *This work supported by the NRL Base Program.
The creation of high-temperature superconducting cables of megawatt range in Russia
NASA Astrophysics Data System (ADS)
Sytnikov, V. E.; Bemert, S. E.; Krivetsky, I. V.; Romashov, M. A.; Popov, D. A.; Fedotov, E. V.; Komandenko, O. V.
2015-12-01
Urgent problems of the power industry in the 21st century require the creation of smart energy systems, providing a high effectiveness of generation, transmission, and consumption of electric power. Simultaneously, the requirements for controllability of power systems and ecological and resource-saving characteristics at all stages of production and distribution of electric power are increased. One of the decision methods of many problems of the power industry is the development of new high-efficiency electrical equipment for smart power systems based on superconducting technologies to ensure a qualitatively new level of functioning of the electric power industry. The intensive research and development of new types of electrical devices based on superconductors are being carried out in many industrialized advanced countries. Interest in such developments has especially increased in recent years owing to the discovery of so-called high-temperature superconductors (HTS) that do not require complicated and expensive cooling devices. Such devices can operate at cooling by inexpensive and easily accessible liquid nitrogen. Taking into account the obvious advantages of superconducting cable lines for the transmission of large power flows through an electrical network, as compared with conventional cables, the Federal Grid Company of Unified Energy System (JSC FGC UES) initiated a research and development program including the creation of superconducting HTS AC and DC cable lines. Two cable lines for the transmitted power of 50 MVA/MW at 20 kV were manufactured and tested within the framework of the program.
Semiconductor diode laser device adjuvanting intradermal vaccine
Kimizuka, Yoshifumi; Callahan, John J.; Huang, Zilong; Morse, Kaitlyn; Katagiri, Wataru; Shigeta, Ayako; Bronson, Roderick; Takeuchi, Shu; Shimaoka, Yusuke; Chan, Megan P. K.; Zeng, Yang; Li, Binghao; Chen, Huabiao; Tan, Rhea Y. Y.; Dwyer, Conor; Mulley, Tyler; Leblanc, Pierre; Goudie, Calum; Gelfand, Jeffrey; Tsukada, Kosuke; Brauns, Timothy; Poznansky, Mark C.; Bean, David; Kashiwagi, Satoshi
2017-01-01
A brief exposure of skin to a low-power, non-tissue damaging laser light has been demonstrated to augment immune responses to intradermal vaccination. Both preclinical and clinical studies show that this approach is simple, effective, safe and well tolerated compared to standard chemical or biological adjuvants. Until now, these laser exposures have been performed using a diode-pumped solid-state laser (DPSSL) devices, which are expensive and require labor-intensive maintenance and special training. Development of an inexpensive, easy-to-use and small device would form an important step in translating this technology toward clinical application Here we report that we have established a handheld, near-infrared (NIR) laser device using semiconductor diodes emitting either 1061, 1258, or 1301 nm light that costs less than $4,000, and that this device replicates the adjuvant effect of a DPSSL system in a mouse model of influenza vaccination. Our results also indicate that a broader range of NIR laser wavelengths possess the ability to enhance vaccine immune responses, allowing engineering options for the device design. This small, low-cost device establishes the feasibility of using a laser adjuvant approach for mass-vaccination programs in a clinical setting, opens the door for broader testing of this technology with a variety of vaccines and forms the foundation for development of devices ready for use in the clinic. PMID:28365253
Semiconductor diode laser device adjuvanting intradermal vaccine.
Kimizuka, Yoshifumi; Callahan, John J; Huang, Zilong; Morse, Kaitlyn; Katagiri, Wataru; Shigeta, Ayako; Bronson, Roderick; Takeuchi, Shu; Shimaoka, Yusuke; Chan, Megan P K; Zeng, Yang; Li, Binghao; Chen, Huabiao; Tan, Rhea Y Y; Dwyer, Conor; Mulley, Tyler; Leblanc, Pierre; Goudie, Calum; Gelfand, Jeffrey; Tsukada, Kosuke; Brauns, Timothy; Poznansky, Mark C; Bean, David; Kashiwagi, Satoshi
2017-04-25
A brief exposure of skin to a low-power, non-tissue damaging laser light has been demonstrated to augment immune responses to intradermal vaccination. Both preclinical and clinical studies show that this approach is simple, effective, safe and well tolerated compared to standard chemical or biological adjuvants. Until now, these laser exposures have been performed using a diode-pumped solid-state laser (DPSSL) devices, which are expensive and require labor-intensive maintenance and special training. Development of an inexpensive, easy-to-use and small device would form an important step in translating this technology toward clinical application. Here we report that we have established a handheld, near-infrared (NIR) laser device using semiconductor diodes emitting either 1061, 1258, or 1301nm light that costs less than $4000, and that this device replicates the adjuvant effect of a DPSSL system in a mouse model of influenza vaccination. Our results also indicate that a broader range of NIR laser wavelengths possess the ability to enhance vaccine immune responses, allowing engineering options for the device design. This small, low-cost device establishes the feasibility of using a laser adjuvant approach for mass-vaccination programs in a clinical setting, opens the door for broader testing of this technology with a variety of vaccines and forms the foundation for development of devices ready for use in the clinic. Copyright © 2017 Elsevier Ltd. All rights reserved.
Quantum computing: a prime modality in neurosurgery's future.
Lee, Brian; Liu, Charles Y; Apuzzo, Michael L J
2012-11-01
With each significant development in the field of neurosurgery, our dependence on computers, small and large, has continuously increased. From something as mundane as bipolar cautery to sophisticated intraoperative navigation with real-time magnetic resonance imaging-assisted surgical guidance, both technologies, however simple or complex, require computational processing power to function. The next frontier for neurosurgery involves developing a greater understanding of the brain and furthering our capabilities as surgeons to directly affect brain circuitry and function. This has come in the form of implantable devices that can electronically and nondestructively influence the cortex and nuclei with the purpose of restoring neuronal function and improving quality of life. We are now transitioning from devices that are turned on and left alone, such as vagus nerve stimulators and deep brain stimulators, to "smart" devices that can listen and react to the body as the situation may dictate. The development of quantum computers and their potential to be thousands, if not millions, of times faster than current "classical" computers, will significantly affect the neurosciences, especially the field of neurorehabilitation and neuromodulation. Quantum computers may advance our understanding of the neural code and, in turn, better develop and program implantable neural devices. When quantum computers reach the point where we can actually implant such devices in patients, the possibilities of what can be done to interface and restore neural function will be limitless. Copyright © 2012 Elsevier Inc. All rights reserved.
Comparison of cyclic correlation algorithm implemented in matlab and python
NASA Astrophysics Data System (ADS)
Carr, Richard; Whitney, James
Simulation is a necessary step for all engineering projects. Simulation gives the engineers an approximation of how their devices will perform under different circumstances, without hav-ing to build, or before building a physical prototype. This is especially true for space bound devices, i.e., space communication systems, where the impact of system malfunction or failure is several orders of magnitude over that of terrestrial applications. Therefore having a reliable simulation tool is key in developing these devices and systems. Math Works Matrix Laboratory (MATLAB) is a matrix based software used by scientists and engineers to solve problems and perform complex simulations. MATLAB has a number of applications in a wide variety of fields which include communications, signal processing, image processing, mathematics, eco-nomics and physics. Because of its many uses MATLAB has become the preferred software for many engineers; it is also very expensive, especially for students and startups. One alternative to MATLAB is Python. The Python is a powerful, easy to use, open source programming environment that can be used to perform many of the same functions as MATLAB. Python programming environment has been steadily gaining popularity in niche programming circles. While there are not as many function included in the software as MATLAB, there are many open source functions that have been developed that are available to be downloaded for free. This paper illustrates how Python can implement the cyclic correlation algorithm and com-pares the results to the cyclic correlation algorithm implemented in the MATLAB environment. Some of the characteristics to be compared are the accuracy and precision of the results, and the length of the programs. The paper will demonstrate that Python is capable of performing simulations of complex algorithms such cyclic correlation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gorenstein, David
The objectives of this program are to promote the mission of the Department of Energy (DOE) Science, Technology, Engineering, Math (STEM) Program by recruiting students to science and engineering disciplines with the intent of mentoring and supporting the next generation of scientists; to foster interdisciplinary and collaborative research under the sponsorship of ANH for the discovery and design of nano-based materials and devices with novel structures, functions, and properties; and to prepare a diverse work force of scientists, engineers, and clinicians by utilizing the unique intellectual and physical resources to develop novel nanotechnology paradigms for clinical application.
Advanced Devices for Cryogenic Thermal Management
NASA Astrophysics Data System (ADS)
Bugby, D.; Stouffer, C.; Garzon, J.; Beres, M.; Gilchrist, A.
2006-04-01
This paper describes six advanced cryogenic thermal management devices/subsystems developed by Swales Aerospace for ground/space-based applications of interest to NASA, DoD, and the commercial sector. The devices/subsystems described herein include the following: (a) a differential thermal expansion cryogenic thermal switch (DTE-CTSW) constructed with high purity aluminum end-pieces and an Ultem support rod for the 6 K Mid-Infrared Instrument (MIRI) on the James Webb Space Telescope (JWST) (b) a quad-redundant DTE-CTSW assembly for the 35 K science instruments (NIRCam, NIRSpec, and FGS) mounted on the JWST Integrated Science Instrument Module (ISIM) (c) a cryogenic diode heat pipe (CDHP) thermal switching system using methane as the working fluid for the 100 K CRISM hyperspectral mapping instrument on the Mars Reconnaissance Orbiter (MRO) and (d) three additional devices/subsystems developed during the AFRL-sponsored CRYOTOOL program, which include a dual DTE-CTSW/dual cryocooler test bed, a miniaturized neon cryogenic loop heat pipe (mini-CLHP), and an across gimbal cryogenic thermal transport system (GCTTS). For the first three devices/subsystems mentioned above, this paper describes key aspects of the development efforts including concept definition, design, fabrication, and testing. For the latter three, this paper provides brief overview descriptions as key details are provided in a related paper.
Gschwind, Michael K
2013-04-16
Mechanisms for generating and executing programs for a floating point (FP) only single instruction multiple data (SIMD) instruction set architecture (ISA) are provided. A computer program product comprising a computer recordable medium having a computer readable program recorded thereon is provided. The computer readable program, when executed on a computing device, causes the computing device to receive one or more instructions and execute the one or more instructions using logic in an execution unit of the computing device. The logic implements a floating point (FP) only single instruction multiple data (SIMD) instruction set architecture (ISA), based on data stored in a vector register file of the computing device. The vector register file is configured to store both scalar and floating point values as vectors having a plurality of vector elements.
FAA bulk technology overview for explosives detection
NASA Astrophysics Data System (ADS)
Novakoff, Alan K.
1993-04-01
The Federal Aviation Administration (FAA) is the leading federal agency responsible for encouraging and fostering the development of a safe, secure, and efficient national airspace system (NAS). Our goal is to establish an operating environment that ensures a threat-free system to preclude acts of terrorism and fatalities. As part of the process to meet this goal, our research and development activities continually search for technologies to ensure aviation security. Recent acts of terrorism against the aviation community have demonstrated an increasing level of sophistication in the design and deployment of explosive devices. In order to prevent the introduction of explosives onto an aircraft they must be detected prior to passenger and baggage loading. The Bulk Detection program is one method of developing a number of technologies that 'see' into and 'alarm' on suspect baggage. These detection devices must be capable of providing this serve with a confidence commensurate with the state-of-the- art available today. This program utilizes the expertise of government agencies, universities and industries working toward constructing their plans and executing their designs to produce the best available equipment.
Uncooled infrared photodetectors in Poland
NASA Astrophysics Data System (ADS)
Piotrowski, Jozef; Piotrowski, Adam
2005-09-01
The history and present status of the middle and long wavelength Hg1xCdxTe infrared detectors in Poland are reviewed. Research and development efforts in Poland were concentrated mostly on uncooled market niche. Technology of the infrared photodetectors has been developed by several research groups. The devices are based on mercury-based variable band gap semiconductor alloys. Modified isothermal vapor phase epitaxy (ISOVPE) has been used for many years for research and commercial fabrication of photoconductive, photoelectromagnetic and other devices. Bulk growth and liquid phase epitaxy was also used. At present, the fabrication of IR devices relies on low temperature epitaxial technique, namely metalorganic vapor phase deposition (MOCVD), frequently in combination with the ISOVPE. Photoconductive and photoelectromagnetic detectors are still in production. The devices are gradually replaced with photovoltaic devices which offer inherent advantages of no electric or magnetic bias, no heat load and no flicker noise. Potentially, the PV devices could offer high performance and very fast response. Actually, the uncooled long wavelength devices of conventional design suffer from two issues; namely low quantum efficiency and very low junction resistance. It makes them useless for practical applications. The problems have been solved with advanced 3D band gap engineered architecture, multiple cell heterojunction devices connected in series, monolithic integration of the detectors with microoptics and other improvements. Present fabrication program includes devices which are optimized for operation at any wavelength within a wide spectral range 1-15 μm and 200-300 K temperature range. Special solutions have been applied to improve speed of response. Some devices show picoseconds range response time. The devices have found numerous civilian and military applications.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pei, Qibing
2017-10-06
This project developed an integrated substrate which organic light emitting diode (OLED) panel developers could employ the integrated substrate to fabricate OLED devices with performance and projected cost meeting the MYPP targets of the Solid State Lighting Program of the Department of Energy. The project optimized the composition and processing conditions of the integrated substrate for OLED light extraction efficiency and overall performance. The process was further developed for scale up to a low-cost process and fabrication of prototype samples. The encapsulation of flexible OLEDs based on this integrated substrate was also investigated using commercial flexible barrier films.
Simulation Model Development for Icing Effects Flight Training
NASA Technical Reports Server (NTRS)
Barnhart, Billy P.; Dickes, Edward G.; Gingras, David R.; Ratvasky, Thomas P.
2003-01-01
A high-fidelity simulation model for icing effects flight training was developed from wind tunnel data for the DeHavilland DHC-6 Twin Otter aircraft. First, a flight model of the un-iced airplane was developed and then modifications were generated to model the icing conditions. The models were validated against data records from the NASA Twin Otter Icing Research flight test program with only minimal refinements being required. The goals of this program were to demonstrate the effectiveness of such a simulator for training pilots to recognize and recover from icing situations and to establish a process for modeling icing effects to be used for future training devices.
Dopant atoms as quantum components in silicon nanoscale devices
NASA Astrophysics Data System (ADS)
Zhao, Xiaosong; Han, Weihua; Wang, Hao; Ma, Liuhong; Li, Xiaoming; Zhang, Wang; Yan, Wei; Yang, Fuhua
2018-06-01
Recent progress in nanoscale fabrication allows many fundamental studies of the few dopant atoms in various semiconductor nanostructures. Since the size of nanoscale devices has touched the limit of the nature, a single dopant atom may dominate the performance of the device. Besides, the quantum computing considered as a future choice beyond Moore's law also utilizes dopant atoms as functional units. Therefore, the dopant atoms will play a significant role in the future novel nanoscale devices. This review focuses on the study of few dopant atoms as quantum components in silicon nanoscale device. The control of the number of dopant atoms and unique quantum transport characteristics induced by dopant atoms are presented. It can be predicted that the development of nanoelectronics based on dopant atoms will pave the way for new possibilities in quantum electronics. Project supported by National Key R&D Program of China (No. 2016YFA0200503).
Zens, Martin; Grotejohann, Birgit; Tassoni, Adrian; Duttenhoefer, Fabian; Südkamp, Norbert P; Niemeyer, Philipp
2017-05-23
Observational studies have proven to be a valuable resource in medical research, especially when performed on a large scale. Recently, mobile device-based observational studies have been discovered by an increasing number of researchers as a promising new source of information. However, the development and deployment of app-based studies is not trivial and requires profound programming skills. The aim of this project was to develop a modular online research platform that allows researchers to create medical studies for mobile devices without extensive programming skills. The platform approach for a modular research platform consists of three major components. A Web-based platform forms the researchers' main workplace. This platform communicates via a shared database with a platform independent mobile app. Furthermore, a separate Web-based login platform for physicians and other health care professionals is outlined and completes the concept. A prototype of the research platform has been developed and is currently in beta testing. Simple questionnaire studies can be created within minutes and published for testing purposes. Screenshots of an example study are provided, and the general working principle is displayed. In this project, we have created a basis for a novel research platform. The necessity and implications of a modular approach were displayed and an outline for future development given. International researchers are invited and encouraged to participate in this ongoing project. ©Martin Zens, Birgit Grotejohann, Adrian Tassoni, Fabian Duttenhoefer, Norbert P Südkamp, Philipp Niemeyer. Originally published in JMIR Research Protocols (http://www.researchprotocols.org), 23.05.2017.
NASA Astrophysics Data System (ADS)
Tang, Lan-Feng; Yu, Guang; Lu, Hai; Wu, Chen-Fei; Qian, Hui-Min; Zhou, Dong; Zhang, Rong; Zheng, You-Dou; Huang, Xiao-Ming
2015-08-01
The influence of white light illumination on the stability of an amorphous InGaZnO thin film transistor is investigated in this work. Under prolonged positive gate bias stress, the device illuminated by white light exhibits smaller positive threshold voltage shift than the device stressed under dark. There are simultaneous degradations of field-effect mobility for both stressed devices, which follows a similar trend to that of the threshold voltage shift. The reduced threshold voltage shift under illumination is explained by a competition between bias-induced interface carrier trapping effect and photon-induced carrier detrapping effect. It is further found that white light illumination could even excite and release trapped carriers originally exiting at the device interface before positive gate bias stress, so that the threshold voltage could recover to an even lower value than that in an equilibrium state. The effect of photo-excitation of oxygen vacancies within the a-IGZO film is also discussed. Project supported by the State Key Program for Basic Research of China (Grant Nos. 2011CB301900 and 2011CB922100) and the Priority Academic Program Development of Jiangsu Higher Education Institutions, China.
B-1 AFT Nacelle Flow Visualization Study
NASA Technical Reports Server (NTRS)
Celniker, Robert
1975-01-01
A 2-month program was conducted to perform engineering evaluation and design tasks to prepare for visualization and photography of the airflow along the aft portion of the B-1 nacelles and nozzles during flight test. Several methods of visualizing the flow were investigated and compared with respect to cost, impact of the device on the flow patterns, suitability for use in the flight environment, and operability throughout the flight. Data were based on a literature search and discussions with the test personnel. Tufts were selected as the flow visualization device in preference to several other devices studied. A tuft installation pattern has been prepared for the right-hand aft nacelle area of B-1 air vehicle No.2. Flight research programs to develop flow visualization devices other than tufts for use in future testing are recommended. A design study was conducted to select a suitable motion picture camera, to select the camera location, and to prepare engineering drawings sufficient to permit installation of the camera. Ten locations on the air vehicle were evaluated before the selection of the location in the horizontal stabilizer actuator fairing. The considerations included cost, camera angle, available volume, environmental control, flutter impact, and interference with antennas or other instrumentation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Potok, Thomas; Schuman, Catherine; Patton, Robert
The White House and Department of Energy have been instrumental in driving the development of a neuromorphic computing program to help the United States continue its lead in basic research into (1) Beyond Exascale—high performance computing beyond Moore’s Law and von Neumann architectures, (2) Scientific Discovery—new paradigms for understanding increasingly large and complex scientific data, and (3) Emerging Architectures—assessing the potential of neuromorphic and quantum architectures. Neuromorphic computing spans a broad range of scientific disciplines from materials science to devices, to computer science, to neuroscience, all of which are required to solve the neuromorphic computing grand challenge. In our workshopmore » we focus on the computer science aspects, specifically from a neuromorphic device through an application. Neuromorphic devices present a very different paradigm to the computer science community from traditional von Neumann architectures, which raises six major questions about building a neuromorphic application from the device level. We used these fundamental questions to organize the workshop program and to direct the workshop panels and discussions. From the white papers, presentations, panels, and discussions, there emerged several recommendations on how to proceed.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-14
...-0061] Highway Safety Programs; Conforming Products List of Evidential Breath Alcohol Measurement... Evidential Breath Alcohol Measurement Devices dated, September 17, 1993 (58 FR 48705). DATES: Effective Date... Safety Administration (NHTSA) published the Standards for Devices to Measure Breath Alcohol (38 FR 30459...
DARPA challenge: developing new technologies for brain and spinal injuries
NASA Astrophysics Data System (ADS)
Macedonia, Christian; Zamisch, Monica; Judy, Jack; Ling, Geoffrey
2012-06-01
The repair of traumatic injuries to the central nervous system remains among the most challenging and exciting frontiers in medicine. In both traumatic brain injury and spinal cord injuries, the ultimate goals are to minimize damage and foster recovery. Numerous DARPA initiatives are in progress to meet these goals. The PREventing Violent Explosive Neurologic Trauma program focuses on the characterization of non-penetrating brain injuries resulting from explosive blast, devising predictive models and test platforms, and creating strategies for mitigation and treatment. To this end, animal models of blast induced brain injury are being established, including swine and non-human primates. Assessment of brain injury in blast injured humans will provide invaluable information on brain injury associated motor and cognitive dysfunctions. The Blast Gauge effort provided a device to measure warfighter's blast exposures which will contribute to diagnosing the level of brain injury. The program Cavitation as a Damage Mechanism for Traumatic Brain Injury from Explosive Blast developed mathematical models that predict stresses, strains, and cavitation induced from blast exposures, and is devising mitigation technologies to eliminate injuries resulting from cavitation. The Revolutionizing Prosthetics program is developing an avant-garde prosthetic arm that responds to direct neural control and provides sensory feedback through electrical stimulation. The Reliable Neural-Interface Technology effort will devise technologies to optimally extract information from the nervous system to control next generation prosthetic devices with high fidelity. The emerging knowledge and technologies arising from these DARPA programs will significantly improve the treatment of brain and spinal cord injured patients.
Reusing single-use devices in hospitals: a case study
NASA Astrophysics Data System (ADS)
Srivastava, Rajesh
2004-02-01
Traditionally, Single Use Devices (SUDs) have been used and discarded, as the name suggests. These SUDs include operating room devices used in areas such as arthroscopy and laparoscopy, devices such as catheters in cardiovascular surgery and in endoscopy, and other general products. However, many of these devices can be remanufactured. Hospitals face challenges in reducing costs. They are increasingly turning to reusing these SUDs. The use of SUDs by a local hospital is examined with the focus on the savings achieved through the program, as well as problems encountered in the process of implementing the program. Various aspects of the remanufacture and use of such devices, including the economics, quality, and customer perception are examined, as well as medical users attitudes. The success of the current program, and its viability in the future are also examined.
NASA Technical Reports Server (NTRS)
Leopold, Daniel J.
2002-01-01
The primary goal of this research project was to further extend the use of advanced heteroepitaxial-semiconductor crystal growth techniques such as molecular beam epitaxy (MBE) and to demonstrate significant gains in UV/blue photonic detection by designing and fabricating atomically-tailored heteroepitaxial GaAlN/GaInN photocathode device structures. This NASA Explorer technology research program has focused on the development of photocathodes for Cherenkov and scintillation radiation detection. Support from the program allowed us to enhance our MBE system to include a nitrogen plasma source and a magnetic bearing turbomolecular pump for delivery and removal of high purity atomic nitrogen during GaAlN/GaInN film growth. Under this program we have also designed, built and incorporated a cesium activation stage. In addition, a connected UHV chamber with photocathode transfer/positioner components as well as a hybrid phototube stage was designed and built to make in-situ quantum efficiency measurements without ever having to remove the photocathodes from UHV conditions. Thus we have constructed a system with the capability to couple atomically-tailored MBE-grown photocathode heterostructures with real high gain readout devices for single photon detection evaluation.
40 CFR 610.10 - Program purpose.
Code of Federal Regulations, 2013 CFR
2013-07-01
... DEVICES Test Procedures and Evaluation Criteria General Provisions § 610.10 Program purpose. (a) The... standardized procedures, the performance of various retrofit devices applicable to automobiles for which fuel... statistical analysis of data from vehicle tests, the evaluation program will determine the effects on fuel...
40 CFR 610.10 - Program purpose.
Code of Federal Regulations, 2014 CFR
2014-07-01
... DEVICES Test Procedures and Evaluation Criteria General Provisions § 610.10 Program purpose. (a) The... standardized procedures, the performance of various retrofit devices applicable to automobiles for which fuel... statistical analysis of data from vehicle tests, the evaluation program will determine the effects on fuel...
40 CFR 610.10 - Program purpose.
Code of Federal Regulations, 2011 CFR
2011-07-01
... DEVICES Test Procedures and Evaluation Criteria General Provisions § 610.10 Program purpose. (a) The... standardized procedures, the performance of various retrofit devices applicable to automobiles for which fuel... statistical analysis of data from vehicle tests, the evaluation program will determine the effects on fuel...
40 CFR 610.10 - Program purpose.
Code of Federal Regulations, 2012 CFR
2012-07-01
... DEVICES Test Procedures and Evaluation Criteria General Provisions § 610.10 Program purpose. (a) The... standardized procedures, the performance of various retrofit devices applicable to automobiles for which fuel... statistical analysis of data from vehicle tests, the evaluation program will determine the effects on fuel...
NASA Astrophysics Data System (ADS)
Gao, Jian; Yu, Qian-Qian; Zhang, Juan; Liu, Yang; Jia, Ruo-Fei; Han, Jun; Wu, Xiao-Ming; Hua, Yu-Lin; Yin, Shou-Gen
2017-08-01
Not Available Project supported by the National Natural Science Foundation of China (Grant No. 60906022), the Natural Science Foundation of Tianjin, China (Grant No. 10JCYBJC01100), the Key Science and Technology Support Program of Tianjin, China (Grant No. 14ZCZDGX00006), and the National High Technology Research and Development Program of China (Grant No. 2013AA014201).
NASA Technical Reports Server (NTRS)
Badescu, Mircea
2014-01-01
Subsurface penetration by coring, drilling or abrading is of great importance for a large number of space and earth applications. An Ultrasonic/Sonic Drill/Corer (USDC) has been in development at JPL's Nondestructive Evaluation and Advanced Actuators (NDEAA) lab as an adaptable tool for many of these applications. The USDC uses a novel drive mechanism to transform the high frequency ultrasonic or sonic vibrations of the tip of a horn into a lower frequency sonic hammering of a drill bit through an intermediate free-flying mass. The USDC device idea has been implemented at various scales from handheld drills to large diameter coring devices. A series of computer programs that model the function and performance of the USDC device were developed and were later integrated into an automated modeling package. The USDC has also evolved from a purely hammering drill to a rotary hammer drill as the design requirements increased form small diameter shallow drilling to large diameter deep coring. A synthesis of the Auto-Gopher development is presented in this paper.
Research to Develop Information Service Aids and Programs for Handicapped Individuals.
ERIC Educational Resources Information Center
Cylke, Frank Kurt; And Others
1980-01-01
Highlights current research relating to the provision of information to disabled persons, including electromechanical technology, tactile technology, and transfer devices and tools for the hearing impaired. A directory identifies pertinent organizations, information dissemination points, and publications. Six references are cited. (FM)
ERIC Educational Resources Information Center
Sigford, Ann; Nelson, Nancy
1998-01-01
Presents a program for elementary teachers to learn how to use hand tools and household appliances to teach the principles of physics. The lesson helps teachers become familiar with simple hand tools, combat the apprehension of mechanical devices, and develop an interest in tools and technology. Session involves disassembling appliances to…
Particle Collections - Skylab Experiment S149
NASA Technical Reports Server (NTRS)
1970-01-01
This photograph shows Skylab's Particle Collection device, a scientific experiment designed to study micro-meteoroid particles in near-Earth space and determine their abundance, mass distribution, composition, and erosive effects. The Marshall Space Flight Center had program management responsibility for the development of Skylab hardware and experiments.
Particle Collection - Skylab Experiment S149
NASA Technical Reports Server (NTRS)
1970-01-01
This chart describes Skylab's Particle Collection device, a scientific experiment designed to study micro-meteoroid particles in near-Earth space and determine their abundance, mass distribution, composition, and erosive effects. The Marshall Space Flight Center had program management responsibility for the development of Skylab hardware and experiments.
Code of Federal Regulations, 2010 CFR
2010-07-01
... applying existing technology to new products and processes in a general way. Advanced research is most... Category 6.3A) programs within Research, Development, Test and Evaluation (RDT&E). Applied research... technology such as new materials, devices, methods and processes. It typically is funded in Applied Research...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fernandes, Ana; Pereira, Rita C.; Sousa, Jorge
The Instituto de Plasmas e Fusao Nuclear (IPFN) has developed dedicated re-configurable modules based on field programmable gate array (FPGA) devices for several nuclear fusion machines worldwide. Moreover, new Advanced Telecommunication Computing Architecture (ATCA) based modules developed by IPFN are already included in the ITER catalogue. One of the requirements for re-configurable modules operating in future nuclear environments including ITER is the remote update capability. Accordingly, this work presents an alternative method for FPGA remote programing to be implemented in new ATCA based re-configurable modules. FPGAs are volatile devices and their programming code is usually stored in dedicated flash memoriesmore » for properly configuration during module power-on. The presented method is capable to store new FPGA codes in Serial Peripheral Interface (SPI) flash memories using the PCIexpress (PCIe) network established on the ATCA back-plane, linking data acquisition endpoints and the data switch blades. The method is based on the Xilinx Quick Boot application note, adapted to PCIe protocol and ATCA based modules. (authors)« less
NASA Technical Reports Server (NTRS)
Pagnutti, Mary; Ryan, Robert E.; Holekamp, Kara; Harrington, Gary; Frisbie, Troy
2006-01-01
A simple and cost-effective, hyperspectral sun photometer for radiometric vicarious remote sensing system calibration, air quality monitoring, and potentially in-situ planetary climatological studies, was developed. The device was constructed solely from off the shelf components and was designed to be easily deployable for support of short-term verification and validation data collects. This sun photometer not only provides the same data products as existing multi-band sun photometers but also the potential of hyperspectral optical depth and diffuse-to-global products. As compared to traditional sun photometers, this device requires a simpler setup, less data acquisition time and allows for a more direct calibration approach. Fielding this instrument has also enabled Stennis Space Center (SSC) Applied Sciences Directorate personnel to cross-calibrate existing sun photometers. This innovative research will position SSC personnel to perform air quality assessments in support of the NASA Applied Sciences Program's National Applications program element as well as to develop techniques to evaluate aerosols in a Martian or other planetary atmosphere.
Design and Analysis of a Novel Centrifugal Braking Device for a Mechanical Antilock Braking System.
Yang, Cheng-Ping; Yang, Ming-Shien; Liu, Tyng
2015-06-01
A new concept for a mechanical antilock braking system (ABS) with a centrifugal braking device (CBD), termed a centrifugal ABS (C-ABS), is presented and developed in this paper. This new CBD functions as a brake in which the output braking torque adjusts itself depending on the speed of the output rotation. First, the structure and mechanical models of the entire braking system are introduced and established. Second, a numerical computer program for simulating the operation of the system is developed. The characteristics of the system can be easily identified and can be designed with better performance by using this program to studying the effects of different design parameters. Finally, the difference in the braking performance between the C-ABS and the braking system with or without a traditional ABS is discussed. The simulation results indicate that the C-ABS can prevent the wheel from locking even if excessive operating force is provided while still maintaining acceptable braking performance.
Using generic tool kits to build intelligent systems
NASA Technical Reports Server (NTRS)
Miller, David J.
1994-01-01
The Intelligent Systems and Robots Center at Sandia National Laboratories is developing technologies for the automation of processes associated with environmental remediation and information-driven manufacturing. These technologies, which focus on automated planning and programming and sensor-based and model-based control, are used to build intelligent systems which are able to generate plans of action, program the necessary devices, and use sensors to react to changes in the environment. By automating tasks through the use of programmable devices tied to computer models which are augmented by sensing, requirements for faster, safer, and cheaper systems are being satisfied. However, because of the need for rapid cost-effect prototyping and multi-laboratory teaming, it is also necessary to define a consistent approach to the construction of controllers for such systems. As a result, the Generic Intelligent System Controller (GISC) concept has been developed. This concept promotes the philosophy of producing generic tool kits which can be used and reused to build intelligent control systems.
Recent Acquisition Reform Through Technology and Workforce Improvements
2016-09-01
HMMWV High Mobility Multipurpose Wheeled Vehicle IED Improvised Explosive Device IRAD Independent Research And Development JCIDS Joint...their specific field within the acquisition community (Eide & Allen, 2012). In 1993, the Government Performance and Results Act (GPRA) was enacted...need arises as the nation’s “adversaries are modernizing at a significant rate, and they are responding rapidly to our development programs and fielded
Development of a Hampton University Program for Novel Breast Cancer Imaging and Therapy Research
2013-04-01
intracavitary brachytherapy procedures during laboratory pre-clinical imaging and dosimetry equipment testing, calibration and data processing, in collaboration... electronics and detector instrumentation development; 4) breast phantom construction and implantation; 5) laboratory pre-clinical device testing...such as the ionization chamber, diode, radiographic verification 6 films and thermoluminescent dosimeters ( TLD ) but the scintillator fiber detectors
Advances in MMIC technology for communications satellites
NASA Technical Reports Server (NTRS)
Leonard, Regis F.
1992-01-01
This paper discusses NASA Lewis Research Center's program for development of monolithic microwave integrated circuits (MMIC) for application in space communications. Emphasis will be on the improved performance in power amplifiers and low noise receivers which has been made possible by the development of new semiconductor materials and devices. Possible applications of high temperature superconductivity for space communications will also be presented.
Early developments in solar cooling equipment
NASA Technical Reports Server (NTRS)
Price, J. M.
1978-01-01
A brief description of a development program to design, fabricate and field test a series of solar operated or driven cooling devices, undertaken by the Marshall Space Flight Center in the context of the Solar Heating and Cooling Demonstration Act of 1974, is presented. Attention is given to two basic design concepts: the Rankine cycle principle and the use of a dessicant for cooling.
VICAR - VIDEO IMAGE COMMUNICATION AND RETRIEVAL
NASA Technical Reports Server (NTRS)
Wall, R. J.
1994-01-01
VICAR (Video Image Communication and Retrieval) is a general purpose image processing software system that has been under continuous development since the late 1960's. Originally intended for data from the NASA Jet Propulsion Laboratory's unmanned planetary spacecraft, VICAR is now used for a variety of other applications including biomedical image processing, cartography, earth resources, and geological exploration. The development of this newest version of VICAR emphasized a standardized, easily-understood user interface, a shield between the user and the host operating system, and a comprehensive array of image processing capabilities. Structurally, VICAR can be divided into roughly two parts; a suite of applications programs and an executive which serves as the interfaces between the applications, the operating system, and the user. There are several hundred applications programs ranging in function from interactive image editing, data compression/decompression, and map projection, to blemish, noise, and artifact removal, mosaic generation, and pattern recognition and location. An information management system designed specifically for handling image related data can merge image data with other types of data files. The user accesses these programs through the VICAR executive, which consists of a supervisor and a run-time library. From the viewpoint of the user and the applications programs, the executive is an environment that is independent of the operating system. VICAR does not replace the host computer's operating system; instead, it overlays the host resources. The core of the executive is the VICAR Supervisor, which is based on NASA Goddard Space Flight Center's Transportable Applications Executive (TAE). Various modifications and extensions have been made to optimize TAE for image processing applications, resulting in a user friendly environment. The rest of the executive consists of the VICAR Run-Time Library, which provides a set of subroutines (image I/O, label I/O, parameter I/O, etc.) to facilitate image processing and provide the fastest I/O possible while maintaining a wide variety of capabilities. The run-time library also includes the Virtual Raster Display Interface (VRDI) which allows display oriented applications programs to be written for a variety of display devices using a set of common routines. (A display device can be any frame-buffer type device which is attached to the host computer and has memory planes for the display and manipulation of images. A display device may have any number of separate 8-bit image memory planes (IMPs), a graphics overlay plane, pseudo-color capabilities, hardware zoom and pan, and other features). The VRDI supports the following display devices: VICOM (Gould/Deanza) IP8500, RAMTEK RM-9465, ADAGE (Ikonas) IK3000 and the International Imaging Systems IVAS. VRDI's purpose is to provide a uniform operating environment not only for an application programmer, but for the user as well. The programmer is able to write programs without being concerned with the specifics of the device for which the application is intended. The VICAR Interactive Display Subsystem (VIDS) is a collection of utilities for easy interactive display and manipulation of images on a display device. VIDS has characteristics of both the executive and an application program, and offers a wide menu of image manipulation options. VIDS uses the VRDI to communicate with display devices. The first step in using VIDS to analyze and enhance an image (one simple example of VICAR's numerous capabilities) is to examine the histogram of the image. The histogram is a plot of frequency of occurrence for each pixel value (0 - 255) loaded in the image plane. If, for example, the histogram shows that there are no pixel values below 64 or above 192, the histogram can be "stretched" so that the value of 64 is mapped to zero and 192 is mapped to 255. Now the user can use the full dynamic range of the display device to display the data and better see its contents. Another example of a VIDS procedure is the JMOVIE command, which allows the user to run animations interactively on the display device. JMOVIE uses the concept of "frames", which are the individual frames which comprise the animation to be viewed. The user loads images into the frames after the size and number of frames has been selected. VICAR's source languages are primarily FORTRAN and C, with some VAX Assembler and array processor code. The VICAR run-time library is designed to work equally easily from either FORTRAN or C. The program was implemented on a DEC VAX series computer operating under VMS 4.7. The virtual memory required is 1.5MB. Approximately 180,000 blocks of storage are needed for the saveset. VICAR (version 2.3A/3G/13H) is a copyrighted work with all copyright vested in NASA and is available by license for a period of ten (10) years to approved licensees. This program was developed in 1989.
ScaMo: Realisation of an OO-functional DSL for cross platform mobile applications development
NASA Astrophysics Data System (ADS)
Macos, Dragan; Solymosi, Andreas
2013-10-01
The software market is dynamically changing: the Internet is going mobile, the software applications are shifting from the desktop hardware onto the mobile devices. The largest markets are the mobile applications for iOS, Android and Windows Phone and for the purpose the typical programming languages include Objective-C, Java and C ♯. The realization of the native applications implies the integration of the developed software into the environments of mentioned mobile operating systems to enable the access to different hardware components of the devices: GPS module, display, GSM module, etc. This paper deals with the definition and possible implementation of an environment for the automatic application generation for multiple mobile platforms. It is based on a DSL for mobile application development, which includes the programming language Scala and a DSL defined in Scala. As part of a multi-stage cross-compiling algorithm, this language is translated into the language of the affected mobile platform. The advantage of our method lies in the expressiveness of the defined language and the transparent source code translation between different languages, which implies, for example, the advantages of debugging and development of the generated code.
Zeitler, Emily P; Al-Khatib, Sana M; Drozda, Joseph P; Kessler, Larry G; Kirtane, Ajay J; Kong, David F; Laschinger, John; Marinac-Dabic, Danica; Morice, Marie-Claude; Reed, Terrie; Sedrakyan, Art; Stein, Kenneth M; Tcheng, James; Krucoff, Mitchell W
2016-01-01
The MDEpiNet is a public-private partnership between the US Food and Drug Administration's Center for Devices and Radiological Health and participating partners. The PASSION program is an MDEpiNet-sponsored program that aims to demonstrate the goals of MDEpiNet by using cardiovascular medical device registries to bridge evidence gaps across the medical device total product life cycle. To this end, a PASSION Think Tank meeting took place in October 2014 in Silver Spring, MD, to facilitate discussion between stakeholders about the successes, challenges, and future novel applications of medical device registries, with particular emphasis on identifying pilot projects. Participants spanned a broad range of groups including patients, device manufacturers, regulators, physicians/academicians, professional societies, providers, and payers. The meeting focus included 4 areas of cardiovascular medicine intended to cultivate interest in 4 MDEpiNet disease-specific/device-specific working groups: coronary intervention, electrophysiology, valvular disease, and peripheral vascular disease. In addition, more general issues applying to registry-based infrastructure and analytical methodologies for assessing device benefit/risk were considered to provide context for the working groups as PASSION programs going forward. This article summarizes the discussions at the meeting and the future directions of the PASSION program. Copyright © 2015 Elsevier Inc. All rights reserved.
Padula, Cynthia A; Paradis, Heidi; Goodwin, Robert; Lynch, Judith; Hegerich-Bartula, Deborah
Medical devices have been identified as an extrinsic risk factor for development of pressure injuries, with as many as 30% to 70% of medical device-related pressure injuries resulting from respiratory equipment. This article describes a quality improvement project undertaken to reduce the occurrence of respiratory device-related pressure injuries in a critically care unit. Multiple actions were implemented to achieve this goal. Respiratory therapists were trained to document occurrences on a daily basis, and apparent cause analyses were conducted on each occurrence. An interdisciplinary team conducted biweekly rounds on patients with respiratory devices and consulted other professionals as indicated. Nurses and respiratory therapists attended an evidence-based, collaborative, educational offering and completed a measure of team functioning before the program and at the end of the study period. The occurrence rates of respiratory device-related pressure injuries were reduced over the project period, and these changes were sustained over the subsequent 12 months.
Programmable Nano-Bio Interfaces for Functional Biointegrated Devices.
Cai, Pingqiang; Leow, Wan Ru; Wang, Xiaoyuan; Wu, Yun-Long; Chen, Xiaodong
2017-07-01
A large amount of evidence has demonstrated the revolutionary role of nanosystems in the screening and shielding of biological systems. The explosive development of interfacing bioentities with programmable nanomaterials has conveyed the intriguing concept of nano-bio interfaces. Here, recent advances in functional biointegrated devices through the precise programming of nano-bio interactions are outlined, especially with regard to the rational assembly of constituent nanomaterials on multiple dimension scales (e.g., nanoparticles, nanowires, layered nanomaterials, and 3D-architectured nanomaterials), in order to leverage their respective intrinsic merits for different functions. Emerging nanotechnological strategies at nano-bio interfaces are also highlighted, such as multimodal diagnosis or "theragnostics", synergistic and sequential therapeutics delivery, and stretchable and flexible nanoelectronic devices, and their implementation into a broad range of biointegrated devices (e.g., implantable, minimally invasive, and wearable devices). When utilized as functional modules of biointegrated devices, these programmable nano-bio interfaces will open up a new chapter for precision nanomedicine. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Instrumentation and control of harmonic oscillators via a single-board microprocessor-FPGA device.
Picone, Rico A R; Davis, Solomon; Devine, Cameron; Garbini, Joseph L; Sidles, John A
2017-04-01
We report the development of an instrumentation and control system instantiated on a microprocessor-field programmable gate array (FPGA) device for a harmonic oscillator comprising a portion of a magnetic resonance force microscope. The specific advantages of the system are that it minimizes computation, increases maintainability, and reduces the technical barrier required to enter the experimental field of magnetic resonance force microscopy. Heterodyne digital control and measurement yields computational advantages. A single microprocessor-FPGA device improves system maintainability by using a single programming language. The system presented requires significantly less technical expertise to instantiate than the instrumentation of previous systems, yet integrity of performance is retained and demonstrated with experimental data.
Instrumentation and control of harmonic oscillators via a single-board microprocessor-FPGA device
NASA Astrophysics Data System (ADS)
Picone, Rico A. R.; Davis, Solomon; Devine, Cameron; Garbini, Joseph L.; Sidles, John A.
2017-04-01
We report the development of an instrumentation and control system instantiated on a microprocessor-field programmable gate array (FPGA) device for a harmonic oscillator comprising a portion of a magnetic resonance force microscope. The specific advantages of the system are that it minimizes computation, increases maintainability, and reduces the technical barrier required to enter the experimental field of magnetic resonance force microscopy. Heterodyne digital control and measurement yields computational advantages. A single microprocessor-FPGA device improves system maintainability by using a single programming language. The system presented requires significantly less technical expertise to instantiate than the instrumentation of previous systems, yet integrity of performance is retained and demonstrated with experimental data.
Processing Device for High-Speed Execution of an Xrisc Computer Program
NASA Technical Reports Server (NTRS)
Ng, Tak-Kwong (Inventor); Mills, Carl S. (Inventor)
2016-01-01
A processing device for high-speed execution of a computer program is provided. A memory module may store one or more computer programs. A sequencer may select one of the computer programs and controls execution of the selected program. A register module may store intermediate values associated with a current calculation set, a set of output values associated with a previous calculation set, and a set of input values associated with a subsequent calculation set. An external interface may receive the set of input values from a computing device and provides the set of output values to the computing device. A computation interface may provide a set of operands for computation during processing of the current calculation set. The set of input values are loaded into the register and the set of output values are unloaded from the register in parallel with processing of the current calculation set.
Free for All: A Case Study Examining Implementation Factors of One-to-One Device Programs
ERIC Educational Resources Information Center
Howard, Sarah K.; Rennie, Ellie
2013-01-01
Despite significant investment in school one-to-one device programs, little is known about which aspects of program implementation work and why. Through a comparison of two implementation models, adopter-diffusion and saturation, and using existing data from the One Laptop per Child Australia laptop program, we explored how factors of…
Quintella, Cristina M; Meira, Marilena; Silva, Weidson Leal; Filho, Rogério G D; Araújo, André L C; Júnior, Elias T S; Sales, Lindolfo J O
2013-12-15
Power transformers are essential for a functioning electrical system and therefore require special attention by maintenance programs because a fault can harm both the company and society. The temperature inside a power transformer and the dissolved gases, which are primarily composed of acetylene, are the two main parameters monitored when detecting faults. This paper describes the development of a device for analyzing the acetylene content in insulating oil using spectrofluorimetry. Using this device introduces a new methodology for the maintaining and operating power transformers. The prototype is currently operating in a substation. The results presented by this system were satisfactory; when compared to chromatographic data, the errors did not exceed 15%. This prototype may be used to confirm the quality of an insulating oil sample to detect faults in power transformers. © 2013 Elsevier B.V. All rights reserved.
Kratzer, Markus; Lasnik, Michael; Röhrig, Sören; Teichert, Christian; Deluca, Marco
2018-01-11
Lead zirconate titanate (PZT) is one of the prominent materials used in polycrystalline piezoelectric devices. Since the ferroelectric domain orientation is the most important parameter affecting the electromechanical performance, analyzing the domain orientation distribution is of great importance for the development and understanding of improved piezoceramic devices. Here, vector piezoresponse force microscopy (vector-PFM) has been applied in order to reconstruct the ferroelectric domain orientation distribution function of polished sections of device-ready polycrystalline lead zirconate titanate (PZT) material. A measurement procedure and a computer program based on the software Mathematica have been developed to automatically evaluate the vector-PFM data for reconstructing the domain orientation function. The method is tested on differently in-plane and out-of-plane poled PZT samples, and the results reveal the expected domain patterns and allow determination of the polarization orientation distribution function at high accuracy.
The aerodynamic performance of several flow control devices for internal flow systems
NASA Technical Reports Server (NTRS)
Eckert, W. T.; Wettlaufer, B. M.; Mort, K. W.
1982-01-01
An experimental reseach and development program was undertaken to develop and document new flow-control devices for use in the major modifications to the 40 by 80 Foot wind tunnel at Ames Research Center. These devices, which are applicable to other facilities as well, included grid-type and quasi-two-dimensional flow straighteners, louver panels for valving, and turning-vane cascades with net turning angles from 0 deg to 90 deg. The tests were conducted at model scale over a Reynolds number range from 2 x 100,000 to 17 x 100,000, based on chord. The results showed quantitatively the performance benefits of faired, low-blockage, smooth-surface straightener systems, and the advantages of curved turning-vanes with hinge-line gaps sealed and a preferred chord-to-gap ratio between 2.5 and 3.0 for 45 deg or 90 deg turns.
Handheld Technology Acceptance in Radiologic Science Education and Training Programs
ERIC Educational Resources Information Center
Powers, Kevin Jay
2012-01-01
The purpose of this study was to explore the behavioral intention of directors of educational programs in the radiologic sciences to adopt handheld devices to aid in managing student clinical data. Handheld devices were described to participants as a technology representing a class of mobile electronic devices including, but not limited to,…
7 CFR 1430.610 - Misrepresentation and scheme or device.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 7 Agriculture 10 2013-01-01 2013-01-01 false Misrepresentation and scheme or device. 1430.610... Disaster Assistance Payment Program II (DDAP-II) § 1430.610 Misrepresentation and scheme or device. (a) In... receive assistance under this program if the producer is determined by CCC to have: (1) Adopted any scheme...
7 CFR 1430.310 - Misrepresentation and scheme or device.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 7 Agriculture 10 2013-01-01 2013-01-01 false Misrepresentation and scheme or device. 1430.310... Disaster Assistance Payment Program § 1430.310 Misrepresentation and scheme or device. (a) In addition to... assistance under this program if the producer is determined by FSA or CCC to have: (1) Adopted any scheme or...
7 CFR 1430.610 - Misrepresentation and scheme or device.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 7 Agriculture 10 2014-01-01 2014-01-01 false Misrepresentation and scheme or device. 1430.610... Disaster Assistance Payment Program II (DDAP-II) § 1430.610 Misrepresentation and scheme or device. (a) In... receive assistance under this program if the producer is determined by CCC to have: (1) Adopted any scheme...
7 CFR 1430.610 - Misrepresentation and scheme or device.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 10 2010-01-01 2010-01-01 false Misrepresentation and scheme or device. 1430.610... Disaster Assistance Payment Program II (DDAP-II) § 1430.610 Misrepresentation and scheme or device. (a) In... receive assistance under this program if the producer is determined by CCC to have: (1) Adopted any scheme...
7 CFR 1430.310 - Misrepresentation and scheme or device.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 10 2010-01-01 2010-01-01 false Misrepresentation and scheme or device. 1430.310... Disaster Assistance Payment Program § 1430.310 Misrepresentation and scheme or device. (a) In addition to... assistance under this program if the producer is determined by FSA or CCC to have: (1) Adopted any scheme or...
7 CFR 1430.310 - Misrepresentation and scheme or device.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 7 Agriculture 10 2011-01-01 2011-01-01 false Misrepresentation and scheme or device. 1430.310... Disaster Assistance Payment Program § 1430.310 Misrepresentation and scheme or device. (a) In addition to... assistance under this program if the producer is determined by FSA or CCC to have: (1) Adopted any scheme or...
7 CFR 1430.610 - Misrepresentation and scheme or device.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 7 Agriculture 10 2011-01-01 2011-01-01 false Misrepresentation and scheme or device. 1430.610... Disaster Assistance Payment Program II (DDAP-II) § 1430.610 Misrepresentation and scheme or device. (a) In... receive assistance under this program if the producer is determined by CCC to have: (1) Adopted any scheme...
7 CFR 1430.310 - Misrepresentation and scheme or device.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 7 Agriculture 10 2012-01-01 2012-01-01 false Misrepresentation and scheme or device. 1430.310... Disaster Assistance Payment Program § 1430.310 Misrepresentation and scheme or device. (a) In addition to... assistance under this program if the producer is determined by FSA or CCC to have: (1) Adopted any scheme or...
7 CFR 1430.310 - Misrepresentation and scheme or device.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 7 Agriculture 10 2014-01-01 2014-01-01 false Misrepresentation and scheme or device. 1430.310... Disaster Assistance Payment Program § 1430.310 Misrepresentation and scheme or device. (a) In addition to... assistance under this program if the producer is determined by FSA or CCC to have: (1) Adopted any scheme or...
7 CFR 1430.610 - Misrepresentation and scheme or device.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 7 Agriculture 10 2012-01-01 2012-01-01 false Misrepresentation and scheme or device. 1430.610... Disaster Assistance Payment Program II (DDAP-II) § 1430.610 Misrepresentation and scheme or device. (a) In... receive assistance under this program if the producer is determined by CCC to have: (1) Adopted any scheme...
US Army Research Laboratory power sources R and D programs
DOE Office of Scientific and Technical Information (OSTI.GOV)
Christopher, H.A.; Gilman, S.; Hamlen, R.P.
1993-05-01
The development and application of new electronic technologies over the recent past has resulted in a major evolution of new electronic battlefield equipment. The need for lighter-weight and more cost effective power sources with higher power/energy density capability is critical to the successful development and deployment of these new, high performance battlefield devices. The current status and thrust of the Army Research Laboratory's (ARL's) battery and fuel cell R and D programs that support these new and emerging applications will be reviewed. Major technical barriers will be identified along with the corresponding proposed approaches to solving these anticipated problems.
The Implementation of Advanced Solar Array Technology in Future NASA Missions
NASA Technical Reports Server (NTRS)
Piszczor, Michael F.; Kerslake, Thomas W.; Hoffman, David J.; White, Steve; Douglas, Mark; Spence, Brian; Jones, P. Alan
2003-01-01
Advanced solar array technology is expected to be critical in achieving the mission goals on many future NASA space flight programs. Current PV cell development programs offer significant potential and performance improvements. However, in order to achieve the performance improvements promised by these devices, new solar array structures must be designed and developed to accommodate these new PV cell technologies. This paper will address the use of advanced solar array technology in future NASA space missions and specifically look at how newer solar cell technologies impact solar array designs and overall power system performance.
1981-03-12
feasibility of a laser suitable for space opera- tion. Its objective is to demonstrate tte laser device technology in 11-37 tion, Its i extracting a high power...acoustic signal processing testbed will officially transfer to the Navy Undersea Surveillance Office at the end of FY 1982. This gives the Navy a...advanced undersea vehicle programs. 2. Air Vehicles and Weapons This addresses innovative concepts such as the X-Wing and the Forward Swept Wing
NASA Astrophysics Data System (ADS)
Mitchell, L. W.
2002-12-01
During the initiation of a new program at the University of North Dakota designed to promote American Indians to engage in geoscience research and complete geoscience related degrees, an evaluation procedure utilizing a modified Learning Potential Assessment Device (LPAD) and Mediated Learning Experiences (MLE) to assess minority student progress was implemented. The program, called Indians Into Geosciences (INGEOS), utilized a modified form of the Learning Potential Assessment Device first to assess cultural factors, determination, and other baseline information, and second, utilized a series of Mediated Learning Experiences to enhance minority students' opportunities in a culturally appropriate, culturally diverse, and scientifically challenging manner in an effort to prepare students for competitive research careers in the geosciences. All of the LPADs and MLEs corresponded directly to the three goals or eight objectives of INGEOS. The three goals of the INGEOS program are: 1) increasing the number of American Indians earning degrees at all levels, 2) engaging American Indians in challenging and technically based scientific research, and 3) preparing American Indians for successful geoscience careers through multicultural community involvement. The eight objectives of the INGEOS program, called the Eight Points of Success, are: 1) spiritual health, 2) social health, 3) physical health, 4) mental health, 5) financial management, 6) research involvement, 7) technical exposure, and 8) multicultural community education. The INGEOS program goals were evaluated strictly quantitatively utilizing a variety of data sources such as grade point averages, number of credits earned, research project information, and developed products. The INGEOS Program goals reflected a combined quantitative score of all participants, whereas the objectives reflected qualitative measures and are specific for each INGEOS participant. Initial results indicate that those participants which show progress through Mediated Learning Experiences within all of the Eight Points of Success, have a higher likelihood of contributing to all three of the INGEOS programs goals.
Development of a Coded Aperture X-Ray Backscatter Imager for Explosive Device Detection
NASA Astrophysics Data System (ADS)
Faust, Anthony A.; Rothschild, Richard E.; Leblanc, Philippe; McFee, John Elton
2009-02-01
Defence R&D Canada has an active research and development program on detection of explosive devices using nuclear methods. One system under development is a coded aperture-based X-ray backscatter imaging detector designed to provide sufficient speed, contrast and spatial resolution to detect antipersonnel landmines and improvised explosive devices. The successful development of a hand-held imaging detector requires, among other things, a light-weight, ruggedized detector with low power requirements, supplying high spatial resolution. The University of California, San Diego-designed HEXIS detector provides a modern, large area, high-temperature CZT imaging surface, robustly packaged in a light-weight housing with sound mechanical properties. Based on the potential for the HEXIS detector to be incorporated as the detection element of a hand-held imaging detector, the authors initiated a collaborative effort to demonstrate the capability of a coded aperture-based X-ray backscatter imaging detector. This paper will discuss the landmine and IED detection problem and review the coded aperture technique. Results from initial proof-of-principle experiments will then be reported.
... of movements, and gait problems. DBS requires careful programming of the stimulator device in order to work ... of movements, and gait problems. DBS requires careful programming of the stimulator device in order to work ...
Double-injection, deep-impurity switch development
NASA Technical Reports Server (NTRS)
Selim, F. A.; Whitson, D. W.
1983-01-01
The overall objective of this program is the development of device design and process techniques for the fabrication of a double-injection, deep-impurity (DI)(2) silicon switch that operates in the 1-10 kV range with conduction current of 10 and 1A, respectively. Other major specifications include a holding voltage of 0 to 5 volts at 1 A anode current, 10 microsecond switching time, and power dissipation of 50 W at 75 C. This report describes work that shows how the results obtained at the University of Cincinnati under NASA Grant NSG-3022 have been applied to larger area and higher voltage devices. The investigations include theoretical, analytical, and experimental studies of device design and processing. Methods to introduce deep levels, such as Au diffusion and electron irradiation, have been carried out to "pin down' the Fermi level and control device-switching characteristics. Different anode, cathode, and gate configurations are presented. Techniques to control the surface electric field of planar structures used for (DI)(2) switches are examined. Various sections of this report describe the device design, wafer-processing techniques, and various measurements which include ac and dc characteristics, 4-point probe, and spreading resistance.
Deairing Techniques for Double-Ended Centrifugal Total Artificial Heart Implantation.
Karimov, Jamshid H; Horvath, David J; Byram, Nicole; Sunagawa, Gengo; Grady, Patrick; Sinkewich, Martin; Moazami, Nader; Sale, Shiva; Golding, Leonard A R; Fukamachi, Kiyotaka
2017-06-01
The unique device architecture of the Cleveland Clinic continuous-flow total artificial heart (CFTAH) requires dedicated and specific air-removal techniques during device implantation in vivo. These procedures comprise special surgical techniques and intraoperative manipulations, as well as engineering design changes and optimizations to the device itself. The current study evaluated the optimal air-removal techniques during the Cleveland Clinic double-ended centrifugal CFTAH in vivo implants (n = 17). Techniques and pump design iterations consisted of developing a priming method for the device and the use of built-in deairing ports in the early cases (n = 5). In the remaining cases (n = 12), deairing ports were not used. Dedicated air-removal ports were not considered an essential design requirement, and such ports may represent an additional risk for pump thrombosis. Careful passive deairing was found to be an effective measure with a centrifugal pump of this design. In this report, the techniques and design changes that were made during this CFTAH development program to enable effective residual air removal and prevention of air embolism during in vivo device implantation are explained. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Fabrication and test of digital output interface devices for gas turbine electronic controls
NASA Technical Reports Server (NTRS)
Newirth, D. M.; Koenig, E. W.
1978-01-01
A program was conducted to develop an innovative digital output interface device, a digital effector with optical feedback of the fuel metering valve position, for future electronic controls for gas turbine engines. A digital effector (on-off solenoids driven directly by on-off signals from a digital electronic controller) with optical position feedback was fabricated, coupled with the fuel metering valve, and tested under simulated engine operating conditions. The testing indicated that a digital effector with optical position feedback is a suitable candidate, with proper development for future digital electronic gas turbine controls. The testing also identified several problem areas which would have to be overcome in a final production configuration.
Multimedia CALLware: The Developer's Responsibility.
ERIC Educational Resources Information Center
Dodigovic, Marina
The early computer-assisted-language-learning (CALL) programs were silent and mostly limited to screen or printer supported written text as the prevailing communication resource. The advent of powerful graphics, sound and video combined with AI-based parsers and sound recognition devices gradually turned the computer into a rather anthropomorphic…
ERIC Educational Resources Information Center
Reed, Dean; Harden, Thomas K.
Robots are mechanical devices that can be programmed to perform some task of manipulation or locomotion under automatic control. This paper discusses: (1) early developments of the robotics industry in the United States; (2) the present structure of the industry; (3) noneconomic factors related to the use of robots; (4) labor considerations…
12 CFR 21.3 - Security program.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 12 Banks and Banking 1 2014-01-01 2014-01-01 false Security program. 21.3 Section 21.3 Banks and Banking COMPTROLLER OF THE CURRENCY, DEPARTMENT OF THE TREASURY MINIMUM SECURITY DEVICES AND PROCEDURES, REPORTS OF SUSPICIOUS ACTIVITIES, AND BANK SECRECY ACT COMPLIANCE PROGRAM Minimum Security Devices and...
12 CFR 21.3 - Security program.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 12 Banks and Banking 1 2013-01-01 2013-01-01 false Security program. 21.3 Section 21.3 Banks and Banking COMPTROLLER OF THE CURRENCY, DEPARTMENT OF THE TREASURY MINIMUM SECURITY DEVICES AND PROCEDURES, REPORTS OF SUSPICIOUS ACTIVITIES, AND BANK SECRECY ACT COMPLIANCE PROGRAM Minimum Security Devices and...
12 CFR 21.3 - Security program.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 12 Banks and Banking 1 2011-01-01 2011-01-01 false Security program. 21.3 Section 21.3 Banks and Banking COMPTROLLER OF THE CURRENCY, DEPARTMENT OF THE TREASURY MINIMUM SECURITY DEVICES AND PROCEDURES, REPORTS OF SUSPICIOUS ACTIVITIES, AND BANK SECRECY ACT COMPLIANCE PROGRAM Minimum Security Devices and...
78 FR 36478 - Accessibility of User Interfaces, and Video Programming Guides and Menus
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-18
... equipment: ``digital apparatus'' and ``navigation devices.'' Specifically, section 204 applies to ``digital... apparatus, including equipment purchased at retail by a consumer to access video programming, would be..., and video programming guides, and menus provided by digital apparatus and navigation devices are...
Controlling Laboratory Processes From A Personal Computer
NASA Technical Reports Server (NTRS)
Will, H.; Mackin, M. A.
1991-01-01
Computer program provides natural-language process control from IBM PC or compatible computer. Sets up process-control system that either runs without operator or run by workers who have limited programming skills. Includes three smaller programs. Two of them, written in FORTRAN 77, record data and control research processes. Third program, written in Pascal, generates FORTRAN subroutines used by other two programs to identify user commands with device-driving routines written by user. Also includes set of input data allowing user to define user commands to be executed by computer. Requires personal computer operating under MS-DOS with suitable hardware interfaces to all controlled devices. Also requires FORTRAN 77 compiler and device drivers written by user.
Choi, Changsoon; Choi, Moon Kee; Liu, Siyi; Kim, Min Sung; Park, Ok Kyu; Im, Changkyun; Kim, Jaemin; Qin, Xiaoliang; Lee, Gil Ju; Cho, Kyoung Won; Kim, Myungbin; Joh, Eehyung; Lee, Jongha; Son, Donghee; Kwon, Seung-Hae; Jeon, Noo Li; Song, Young Min; Lu, Nanshu; Kim, Dae-Hyeong
2017-11-21
Soft bioelectronic devices provide new opportunities for next-generation implantable devices owing to their soft mechanical nature that leads to minimal tissue damages and immune responses. However, a soft form of the implantable optoelectronic device for optical sensing and retinal stimulation has not been developed yet because of the bulkiness and rigidity of conventional imaging modules and their composing materials. Here, we describe a high-density and hemispherically curved image sensor array that leverages the atomically thin MoS 2 -graphene heterostructure and strain-releasing device designs. The hemispherically curved image sensor array exhibits infrared blindness and successfully acquires pixelated optical signals. We corroborate the validity of the proposed soft materials and ultrathin device designs through theoretical modeling and finite element analysis. Then, we propose the ultrathin hemispherically curved image sensor array as a promising imaging element in the soft retinal implant. The CurvIS array is applied as a human eye-inspired soft implantable optoelectronic device that can detect optical signals and apply programmed electrical stimulation to optic nerves with minimum mechanical side effects to the retina.
Modelling and fabrication of high-efficiency silicon solar cells
NASA Astrophysics Data System (ADS)
Rohatgi, A.; Smith, A. W.; Salami, J.
1991-10-01
This report covers the research conducted on modelling and development of high efficiency silicon solar cells during the period May 1989 to August 1990. First, considerable effort was devoted toward developing a ray tracing program for the photovoltaic community to quantify and optimize surface texturing for solar cells. Second, attempts were made to develop a hydrodynamic model for device simulation. Such a model is somewhat slower than drift-diffusion type models like PC-1D, but it can account for more physical phenomena in the device, such as hot carrier effects, temperature gradients, thermal diffusion, and lattice heat flow. In addition, Fermi-Dirac statistics have been incorporated into the model to deal with heavy doping effects more accurately. The third and final component of the research includes development of silicon cell fabrication capabilities and fabrication of high efficiency silicon cells.
Soft x ray window encapsulant for HgI2 detectors
NASA Technical Reports Server (NTRS)
Entine, G.; Shah, K.; Squillante, M.
1987-01-01
HgI2 is an excellent semiconductor material for a low energy, room temperature x-ray spectrometer. The high values of the atomic numbers for its constituent elements gives high x-ray and gamma ray stopping power. The band gap of HgI2 is significantly higher than other commonly used semiconductors. Owing to the large value band gap, the leakage current for HgI2 devices is smaller, thus allowing low noise performance. Devices fabricated from HgI2 crystals have demonstrated energy resolution sufficient to distinguish the x-ray emission from the neighboring elements on the periodic table. Also the power requirements of HgI2 are very low. These characteristics make a HgI2 spectrometer an ideal component in a satellite based detection system. Unfortunately, HgI2 crystals tend to deteriorate with time, even if protected by standard semiconductor encapsulants. This degradation ruins the performance of the device in terms of its energy resolution and pulse amplitude. The degrading mechanism is believed to be material loss occurring from below the electrodes, due to high vapor pressure of HgI2 at room temperature. To address this major obstacle to rapid expansion of HgI2 technology, a research program aimed at improving device stability by encapsulation with inert polymeric materials was carried out. The program focused specifically on optimizing the encapsulant materials and their deposition techniques. The principal objectives for this program were device encapsulation, device testing, and accelerated testing to ensure very long term stability of these high resolution sensors. A variety of encapsulants were investigated with the selection criteria based on their chemical diffusion barrier properties, mechanical stability, reactivity, and morphology of encapsulant films. The investigation covered different classes of encapsulants including solvent based encapsulants, vapor deposited encapsulants, and plasma polymerized encapsulants. A variety of characterization techniques were employed to examine their effectiveness in stabilizing HgI2 devices; these included permeability evaluation, vacuum and heat testing, scanning electron microscopy (SEM) as well as studying the detector performance of coated detectors. The plasma polymerized films appear to have entirely solved the HgI2 degradation problem. Another achievement of this program was the development of an accelerated testing technique which correlates extremely well with long term tesing.
Murakami, Madoka; Suzuki, Yuka; Tominaga, Toshiyoshi
2018-02-23
Delays in the introduction to the Japanese market of drug-eluting stents (DES) developed overseas (i.e., "device lag") decreased sharply between 2004 and 2012. The reduction accompanied a shift in clinical development from a succession pattern (initial product development and approval overseas followed by eventual entrance into the Japanese market) to parallel development (employing multiregional clinical trials (MRCTs)). Although resource-intensive in the short-term, MRCTs are proving to be an effective tool in simultaneous global product development. Creative study designs and the absence of significant ethnic differences in Japanese subjects regarding DES safety and efficacy and the pharmacokinetic behavior of their coating drugs propel this process. More general factors such as medical need and industry incentivization also encourage this shift. Physicians' preference for DES over other percutaneous coronary interventions, the expanding global DES market, and streamlined development and approval prospects each motivate industry to continue investing in DES product development. The efforts of various stakeholders were also integral to overcoming practical obstacles, and contributions by 'Harmonization by Doing' and a premarket collaboration initiative between the USA and Japan were particularly effective. Today, USA/Japan regulatory cooperation is routine, and Japan is now integrated into global medical device development. MRCTs including Japanese subjects, sites, and investigators are now commonplace.
NASA Astrophysics Data System (ADS)
Hicks, S. D.; Aufdenkampe, A. K.; Horsburgh, J. S.; Arscott, D. B.; Muenz, T.; Bressler, D. W.
2016-12-01
The explosion in DIY open-source hardware and software has resulted in the development of affordable and accessible technologies, like drones and weather stations, that can greatly assist the general public in monitoring environmental health and its degradation. It is widely recognized that education and support of audiences in pursuit of STEM literacy and the application of emerging technologies is a challenge for the future of citizen science and for preparing high school graduates to be actively engaged in environmental stewardship. It is also clear that detecting environmental change/degradation over time and space will be greatly enhanced with expanded use of networked, remote monitoring technologies by watershed organizations and citizen scientists if data collection and reporting are properly carried out and curated. However, there are few focused efforts to link citizen scientists and school programs with these emerging tools. We have started a multi-year program to develop hardware and teaching materials for training students and citizen scientists about the use of open source hardware in environmental monitoring. Scientists and educators around the world have started building their own dataloggers and devices using a variety of boards based on open source electronics. This new hardware is now providing researchers with an inexpensive alternative to commercial data logging and transmission hardware. We will present a variety of hardware solutions using the Arduino-compatible EnviroDIY Mayfly board (http://envirodiy.org/mayfly) that can be used to build and deploy a rugged environmental monitoring station using a wide variety of sensors and options, giving the users a fully customizable device for making measurements almost anywhere. A database and visualization system is being developed that will allow the users to view and manage the data their devices are collecting. We will also present our plan for developing curricula and leading workshops to various school programs and citizen scientist groups to teach them how to build, deploy, and maintain their own environmental monitoring stations.
Sentence level auditory comprehension treatment program for aphasic adults.
Naeser, M A; Haas, G; Mazurski, P; Laughlin, S
1986-06-01
The purpose of this study was to investigate whether a newly developed sentence level auditory comprehension (SLAC) treatment program could be used to improve language comprehension test scores in adults with chronic aphasia. Results indicate that the SLAC treatment program can be used with chronic patients; performance on a standardized test (the Token Test) was improved after treatment; and improved performance could not be predicted from either anatomic CT scan lesion sites or pretreatment test scores. One advantage to the SLAC treatment program is that the patient can practice listening independently with a tape recorder device (Language Master) and earphones either in the hospital or at home.
Recent cryocooler progress in Japan
NASA Technical Reports Server (NTRS)
Matsubara, Y.
1985-01-01
The progress of cryocoolers and related devices in Japan is reviewed. The Japanese National Railways has developed the light weight 4 K on-board refrigerators since 1977 as part of the MAGLEV train program. Superconducting and cryogenic fundamental technology was examined which included high performance cryocooler, magnetic refrigerator and superfluid refrigeration. Space cryogenics such as the cooling systems of IR-detectors was studied. Cryocooler for special applications such as cryopump, NMR-CT and JJ devices was investigated. Compact heat exchangers, high performance regenerators and reliable compressors are investigated as a critical component technology.
Gulati, Gaurav Kumar; Chen, Tao; Hinds, Bruce Jackson
2017-01-01
To evaluate the performance of switchable carbon nanotubes (CNT) membrane devices for transdermal nicotine delivery, we have developed an in-vitro microdialysis method that allow us to detect variable transdermal fluxes of nicotine through CNT devices and can be applied directly to in-vivo studies. Microdialysis membranes were placed beneath the porcine skin and its nicotine levels increased 6-8 times when the CNT membrane on skin was turned from OFF to ON state by application of bias. Fluxes in the ON state were approximately 3 times that of commercial nicotine patches and switching times were less than two hours, thus suggesting the improved therapeutic potential of our device. Blue tooth enabled CNT devices that can be programmed by smartphone and coupled with remote counseling application for enhanced smoking cessation treatments. Copyright © 2016. Published by Elsevier Inc.
Morales, Ricardo; Badesa, Francisco J; García-Aracil, Nicolas; Perez-Vidal, Carlos; Sabater, Jose María
2012-01-01
This paper presents a microdevice for monitoring, control and management of electric loads at home. The key idea is to compact the electronic design as much as possible in order to install it inside a Schuko socket. Moreover, the electronic Schuko socket (electronic microdevice + Schuko socket) has the feature of communicating with a central unit and with other microdevices over the existing powerlines. Using the existing power lines, the proposed device can be installed in new buildings or in old ones. The main use of this device is to monitor, control and manage electric loads to save energy and prevent accidents produced by different kind of devices (e.g., iron) used in domestic tasks. The developed smart device is based on a single phase multifunction energy meter manufactured by Analog Devices (ADE7753) to measure the consumption of electrical energy and then to transmit it using a serial interface. To provide current measurement information to the ADE7753, an ultra flat SMD open loop integrated circuit current transducer based on the Hall effect principle manufactured by Lem (FHS-40P/SP600) has been used. Moreover, each smart device has a PL-3120 smart transceiver manufactured by LonWorks to execute the user's program, to communicate with the ADE7753 via serial interface and to transmit information to the central unit via powerline communication. Experimental results show the exactitude of the measurements made using the developed smart device.
Development and testing of tip devices for horizontal axis wind turbines
NASA Technical Reports Server (NTRS)
Gyatt, G. W.; Lissaman, P. B. S.
1985-01-01
A theoretical and field experimental program has been carried out to investigate the use of tip devices on horizontal axis wind turbine rotors. The objective was to improve performance by the reduction of tip losses. While power output can always be increased by a simple radial tip extension, such a modification also results in an increased gale load both because of the extra projected area and longer moment arm. Tip devices have the potential to increase power output without such a structural penalty. A vortex lattice computer model was used to optimize three basic tip configuration types for a 25 kW stall limited commercial wind turbine. The types were a change in tip planform, and a single-element and double-element nonplanar tip extension (winglets). A complete data acquisition system was developed which recorded three wind speed components, ambient pressure, temperature, and turbine output. The system operated unattended and could perform real-time processing of the data, displaying the measured power curve as data accumulated in either a bin sort mode or polynomial curve fit. Approximately 270 hr of perormance data were collected over a three-month period. The sampling interval was 2.4 sec; thrus over 400,000 raw data points were logged. Results for each of the three new tip devices, compared with the original tip, showed a small decrease (of the order of 1 kW) in power output over the measured range of wind speeds from cut-in at about 4 m/s to over 20 m/s, well into the stall limiting region. Changes in orientation and angle-of-attack of the winglets were not made. For aircraft wing tip devices, favorable tip shapes have been reported and it is likely that the tip devices tested in this program did not improve rotor performance because they were not optimally adjusted.
Yamazaki, Hiroshi; O'Leary, Stephen; Moran, Michelle; Briggs, Robert
2014-04-01
Accurate diagnosis of cochlear implant failures is important for management; however, appropriate strategies to assess possible device failures are not always clear. The purpose of this study is to understand correlation between causes of device failure and the presenting clinical symptoms as well as results of in situ integrity testing and to propose effective strategies for diagnosis of device failure. Retrospective case review. Cochlear implant center at a tertiary referral hospital. Twenty-seven cases with suspected device failure of Cochlear Nucleus systems (excluding CI512 failures) on the basis of deterioration in auditory perception from January 2000 to September 2012 in the Melbourne cochlear implant clinic. Clinical presentations and types of abnormalities on in situ integrity testing were compared with modes of device failure detected by returned device analysis. Sudden deterioration in auditory perception was always observed in cases with "critical damage": either fracture of the integrated circuit or most or all of the electrode wires. Subacute or gradually progressive deterioration in auditory perception was significantly associated with a more limited number of broken electrode wires. Cochlear implant mediated auditory and nonauditory symptoms were significantly associated with an insulation problem. An algorithm based on the time course of deterioration in auditory perception and cochlear implant-mediated auditory and nonauditory symptoms was developed on the basis of these retrospective analyses, to help predict the mode of device failure. In situ integrity testing, which included close monitoring of device function in routine programming sessions as well as repeating the manufacturer's integrity test battery, was sensitive enough to detect malfunction in all suspected device failures, and each mode of device failure showed a characteristic abnormality on in situ integrity testing. Our clinical manifestation-based algorithm combined with in situ integrity testing may be useful for accurate diagnosis and appropriate management of device failure. Close monitoring of device function in routine programming sessions as well as repeating the manufacturer's integrity test battery is important if the initial in situ integrity testing is inconclusive because objective evidence of failure in the implanted device is essential to recommend explantation/reimplantation.
Uncooled infrared photodetectors in Poland
NASA Astrophysics Data System (ADS)
Piotrowski, J.; Piotrowski, A.
2006-03-01
The history and present status of the middle and long wavelength Hg1-xCdxTe infrared detectors in Poland are reviewed. Research and development efforts in Poland were concentrated mostly on uncooled market niche. Technology of the infrared photodetectors has been developed by several research groups. The devices are based on mercury-based variable band gap semiconductor alloys. Modified isothermal vapour phase epitaxy (ISOVPE) has been used for many years for research and commercial fabrication of photoconductive, photoelectromagnetic and other devices. Bulk growth and liquid phase epitaxy was also used. At present, the fabrication of IR devices relies on low temperature epitaxial technique, namely metalorganic vapour phase deposition (MOCVD), frequently in combination with the ISOVPE. Photoconductive and photoelectromagnetic detectors are still in production. The devices are gradually replaced with photovoltaic devices which offer inherent advantages of no electric or magnetic bias, no heat load and no flicker noise. Potentially, the PV devices could offer high performance and very fast response. At present, the uncooled long wavelength devices of conventional design suffer from two issues; namely low quantum efficiency and very low junction resistance. It makes them useless for practical applications. The problems have been solved with advanced 3D band gap engineered architecture, multiple cell heterojunction devices connected in series, monolithic integration of the detectors with microoptics and other improvements. Present fabrication program includes devices which are optimized for operation at any wavelength within a wide spectral range 1-15 μm and 200-300 K temperature range. Special solutions have been applied to improve speed of response. Some devices show picoseconds range response time. The devices have found numerous civilian and military applications.
DTD Creation for the Software Technology for Adaptable, Reliable Systems (STARS) Program
1990-06-23
developed to store documents in a format peculiar to the program’s design . Editing the document became easy since word processors adjust all spacing and...descriptive markup may be output to a 3 CDRL 1810 January 26, 1990 variety of devices ranging from high quality typography printers through laser printers...provision for non-SGML material, such as graphics , to be inserted in a document. For these reasons the Computer-Aided Acquisition and Logistics Support
Research and Design of Embedded Wireless Meal Ordering System Based on SQLite
NASA Astrophysics Data System (ADS)
Zhang, Jihong; Chen, Xiaoquan
The paper describes features and internal architecture and developing method of SQLite. And then it gives a design and program of meal ordering system. The system realizes the information interaction among the users and embedded devices with SQLite as database system. The embedded database SQLite manages the data and achieves wireless communication by using Bluetooth. A system program based on Qt/Embedded and Linux drivers realizes the local management of environmental data.
Methods of dental instrument processing, sterilization, and storage--a review.
Thomas, Lisa P; Bebermeyer, Richard D; Dickinson, Sharon K
2005-10-01
A comprehensive instrument processing and sterilization program in the dental office is essential to ensure that the DHCP and the public are protected from disease transmission due to contaminated instruments/ devices. The Centers for Disease Control and Prevention and other organizations have made recommendations to help dental personnel with this aspect of patient care. By following the CDC's latest guidelines, the DHCP can develop an optimal program of dental instrument processing, sterilization and storage.
Virtual collaborative environments: programming and controlling robotic devices remotely
NASA Astrophysics Data System (ADS)
Davies, Brady R.; McDonald, Michael J., Jr.; Harrigan, Raymond W.
1995-12-01
This paper describes a technology for remote sharing of intelligent electro-mechanical devices. An architecture and actual system have been developed and tested, based on the proposed National Information Infrastructure (NII) or Information Highway, to facilitate programming and control of intelligent programmable machines (like robots, machine tools, etc.). Using appropriate geometric models, integrated sensors, video systems, and computing hardware; computer controlled resources owned and operated by different (in a geographic sense as well as legal sense) entities can be individually or simultaneously programmed and controlled from one or more remote locations. Remote programming and control of intelligent machines will create significant opportunities for sharing of expensive capital equipment. Using the technology described in this paper, university researchers, manufacturing entities, automation consultants, design entities, and others can directly access robotic and machining facilities located across the country. Disparate electro-mechanical resources will be shared in a manner similar to the way supercomputers are accessed by multiple users. Using this technology, it will be possible for researchers developing new robot control algorithms to validate models and algorithms right from their university labs without ever owning a robot. Manufacturers will be able to model, simulate, and measure the performance of prospective robots before selecting robot hardware optimally suited for their intended application. Designers will be able to access CNC machining centers across the country to fabricate prototypic parts during product design validation. An existing prototype architecture and system has been developed and proven. Programming and control of a large gantry robot located at Sandia National Laboratories in Albuquerque, New Mexico, was demonstrated from such remote locations as Washington D.C., Washington State, and Southern California.
Holbein, M E Blair; Berglund, Jelena Petrovic; O'Reilly, Erin K; Hartman, Karen; Speicher, Lisa A; Adamo, Joan E; O'Riordan, Gerri; Brown, Jennifer Swanton; Schuff, Kathryn G
2014-06-01
The objective of this study was to provide recommendations for provision of training for sponsor and investigators at Academic Health Centers. A subgroup of the Investigational New Drug/Investigational Device Exemption (IND/IDE) Task Force of the Clinical and Translational Science Award (CTSA) program Regulatory Knowledge Key Function Committee was assembled to specifically address how clinical investigators who hold an IND/IDE and thus assume the role of sponsor-investigators are adequately trained to meet the additional regulatory requirements of this role. The participants who developed the recommendations were representatives of institutions with IND/IDE support programs. Through an informal survey, the task force determined that a variety and mix of models are used to provide support for IND/IDE holders within CTSA institutions. In addition, a CTSA consortium-wide resources survey was used. The participants worked from the models and survey results to develop consensus recommendations to address institutional support, training content, and implementation. The CTSA IND/IDE Task Force recommendations are as follows: (1) Institutions should assess the scope of Food and Drug Administration-regulated research, perform a needs analysis, and provide resources to implement a suitable training program; (2) The model of training program should be tailored to each institution; (3) The training should specifically address the unique role of sponsor-investigators, and the effectiveness of training should be evaluated regularly by methods that fit the model adopted by the institution; and (4) Institutional leadership should mandate sponsor-investigator training and effectively communicate the necessity and availability of training.
Electrical latching of microelectromechanical devices
Garcia, Ernest J.; Sleefe, Gerard E.
2004-11-02
Methods are disclosed for row and column addressing of an array of microelectromechanical (MEM) devices. The methods of the present invention are applicable to MEM micromirrors or memory elements and allow the MEM array to be programmed and maintained latched in a programmed state with a voltage that is generally lower than the voltage required for electrostatically switching the MEM devices.
ERIC Educational Resources Information Center
Bolliger, Doris U.; Shepherd, Craig E.
2018-01-01
As more adults frequent wilderness areas, they bring Internet-enabled devices (e.g., smart phones, tablets) with them. This study focuses on adults' perceptions of these devices in relation to desired outdoor learning experiences. Specifically, researchers examined the perspectives of naturalists who taught outdoor education programs and park…
2013-07-05
In this document, the Commission adopts further measures to improve the structure, efficiency, and quality of the video relay service (VRS) program, reducing the inefficiencies in the program, as well as reducing the risk of waste, fraud, and abuse, and ensuring that the program makes full use of advances in commercially-available technology. These measures involve a fundamental restructuring of the program to support innovation and competition, drive down ratepayer and provider costs, eliminate incentives for waste that have burdened the Telecommunications Relay Services (TRS) Fund in the past, and further protect consumers. The Commission adopts several measures in order to: ensure that VRS users can easily select their provider of choice by promoting the development of interoperability and portability standards; enable consumers to use off-the-shelf devices and deploying a VRS application to work with these devices; create a centralized TRS User Registration Database to ensure VRS user eligibility; encourage competition and innovation in VRS call handling services; spur research and development on VRS services by entering into a Memorandum of Understanding with the National Science Foundation; and pilot a National Outreach Program to educate the general public about relay services. In this document, the Commission also adopts new VRS compensation rates that move these rates toward actual costs over the next four years which will better approximate the actual, reasonable costs of providing VRS, and will reduce the costs of operating the program. The Commission takes these steps to ensure the integrity of the TRS Fund while providing stability and certainty to providers.
Critical soft landing technology issues for future US space missions
NASA Technical Reports Server (NTRS)
Macha, J. M.; Johnson, D. W.; Mcbride, D. D.
1992-01-01
A programmatic need for research and development to support parachute-based landing systems has not existed since the end of the Apollo missions in the mid-1970s. Now, a number of planned space programs require advanced landing capabilities for which the experience and technology base does not currently exist. New requirements for landing on land with controllable, gliding decelerators and for more effective impact attenuation devices justify a renewal of the landing technology development effort that existed during the Mercury, Gemini, and Apollo programs. A study was performed to evaluate the current and projected national capability in landing systems and to identify critical deficiencies in the technology base required to support the Assured Crew Return Vehicle and the Two-Way Manned Transportation System. A technology development program covering eight landing system performance issues is recommended.
ERIC Educational Resources Information Center
Schlenker, Richard M.
This manual is a "how to" training device for developing inventory records in the AppleWorks program using an Apple IIe or Apple IIGS Computer with Duodisk or two disk drives and an 80-column card. The manual provides step-by-step directions, and includes 17 figures depicting the computer screen at the various stages of the inventory…
Zeitler, Emily P.; Al-Khatib, Sana M.; Drozda, Joseph P.; Kessler, Larry G.; Kirtane, Ajay J.; Kong, David F.; Laschinger, John; Marinac-Dabic, Danica; Morice, Marie-Claude; Reed, Terrie; Sedrakyan, Art; Stein, Kenneth M.; Tcheng, James; Krucoff, Mitchell W.
2015-01-01
The Medical Device Epidemiological Network Initiative (MDEpiNet) is a public-private partnership between the US Food and Drug Administration (FDA) Center for Devices and Radiological Health (CDRH) and participating partners. The Predictable and SuStainable Implementation of National Cardiovascular Registries (PASSION) program is an MDEpiNet-sponsored program which aims to demonstrate the goals of MDEpiNet by using cardiovascular medical device registries to bridge evidence gaps across the medical device total product life cycle (TPLC). To this end, a PASSION Think Tank meeting took place in October 2014 in Silver Spring, MD, to facilitate discussion between stakeholders about the successes, challenges, and future novel applications of medical device registries, with particular emphasis on identifying pilot projects. Participants spanned a broad range of groups including patients, device manufacturers, regulators, physicians/academicians, professional societies, providers, and payers. The meeting focus included four areas of cardiovascular medicine intended to cultivate interest in four MDEpiNet Disease Specific/Device Specific Working Groups: coronary intervention, electrophysiology, valvular disease, and peripheral vascular disease. In addition, more general issues applying to registry-based infrastructure and analytical methodologies for assessing device benefit/risk were considered to provide context for the Working Groups as PASSION programs going forward. This article summarizes the discussions at the meeting and the future directions of the PASSION program. PMID:26699602
NASA Technical Reports Server (NTRS)
Gorenstein, P.
1985-01-01
A program for the development of high throughput instrumentation for X-ray astronomy based upon focusing optics is being carried out by the Smithsonian Astrophysical Observatory. The instrumentation is applicable to investigations requiring large area focusing optics for direct imaging or dispersive spectroscopy. The long range goals of this program are the development of telescopes and gratings for future major X-ray astronomy facilities, including additions to the LAMAR OSS-2/SHEAL experiment after the initial flights. Tests of the devices and their more immediate utilization in scientific investigations can be carried out with SPARTAN payloads deployed and retrieved by the Space Shuttle. However, the present backlog of approved SPARTAN missions is longer than the three-year duration of the program described in this program. Laboratory studies and breadboarding of instrumentation are discussed.
Maillot, Pauline; Dommes, Aurélie; Dang, Nguyen-Thong; Vienne, Fabrice
2017-02-01
A virtual-reality training program has been developed to help older pedestrians make safer street-crossing decisions in two-way traffic situations. The aim was to develop a small-scale affordable and transportable simulation device that allowed transferring effects to a full-scale device involving actual walking. 20 younger adults and 40 older participants first participated in a pre-test phase to assess their street crossings using both full-scale and small-scale simulation devices. Then, a trained older group (20 participants) completed two 1.5-h training sessions with the small-scale device, whereas an older control group received no training (19 participants). Thereafter, the 39 older trained and untrained participants took part in a 1.5-h post-test phase again with both devices. Pre-test phase results suggested significant differences between both devices in the group of older participants only. Unlike younger participants, older participants accepted more often to cross and had more collisions on the small-scale simulation device than on the full-scale one. Post-test phase results showed that training older participants on the small-scale device allowed a significant global decrease in the percentage of accepted crossings and collisions on both simulation devices. But specific improvements regarding the way participants took into account the speed of approaching cars and vehicles in the far lane were notable only on the full-scale simulation device. The findings suggest that the small-scale simulation device triggers a greater number of unsafe decisions compared to a full-scale one that allows actual crossings. But findings reveal that such a small-scale simulation device could be a good means to improve the safety of street-crossing decisions and behaviors among older pedestrians, suggesting a transfer of learning effect between the two simulation devices, from training people with a miniature device to measuring their specific progress with a full-scale one. Copyright © 2016 Elsevier Ltd. All rights reserved.