Sample records for device experimental evaluation

  1. Experimental evaluation of cooling efficiency of the high performance cooling device

    NASA Astrophysics Data System (ADS)

    Nemec, Patrik; Malcho, Milan

    2016-06-01

    This work deal with experimental evaluation of cooling efficiency of cooling device capable transfer high heat fluxes from electric elements to the surrounding. The work contain description of cooling device, working principle of cooling device, construction of cooling device. Experimental part describe the measuring method of device cooling efficiency evaluation. The work results are presented in graphic visualization of temperature dependence of the contact area surface between cooling device evaporator and electronic components on the loaded heat of electronic components in range from 250 to 740 W and temperature dependence of the loop thermosiphon condenser surface on the loaded heat of electronic components in range from 250 to 740 W.

  2. The Captive Helicopter as a Training Device: Experimental Evaluation of a Concept. Technical Report 68-9.

    ERIC Educational Resources Information Center

    Caro, Paul W., Jr.; And Others

    As part of the Army's effort to use synthetic devices to improve training, researchers evaluated a captive helicopter attached to a ground effects machine. Experimental groups received varying amounts of pre-flight practice tasks designed to develop flight skills, while control groups received no device training. Student flight performance during…

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nemec, Patrik, E-mail: patrik.nemec@fstroj.uniza.sk; Malcho, Milan, E-mail: milan.malcho@fstroj.uniza.sk

    This work deal with experimental evaluation of cooling efficiency of cooling device capable transfer high heat fluxes from electric elements to the surrounding. The work contain description of cooling device, working principle of cooling device, construction of cooling device. Experimental part describe the measuring method of device cooling efficiency evaluation. The work results are presented in graphic visualization of temperature dependence of the contact area surface between cooling device evaporator and electronic components on the loaded heat of electronic components in range from 250 to 740 W and temperature dependence of the loop thermosiphon condenser surface on the loaded heatmore » of electronic components in range from 250 to 740 W.« less

  4. 42 CFR 405.213 - Re-evaluation of a device categorization.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 2 2011-10-01 2011-10-01 false Re-evaluation of a device categorization. 405.213... Decisions That Relate to Health Care Technology § 405.213 Re-evaluation of a device categorization. (a... experimental/investigational (Category A) may request re-evaluation of the categorization decision. (2) A...

  5. 42 CFR 405.213 - Re-evaluation of a device categorization.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 2 2010-10-01 2010-10-01 false Re-evaluation of a device categorization. 405.213... Decisions That Relate to Health Care Technology § 405.213 Re-evaluation of a device categorization. (a... experimental/investigational (Category A) may request re-evaluation of the categorization decision. (2) A...

  6. Evaluation Plan for ORBIS

    DOT National Transportation Integrated Search

    1974-03-01

    This report contains the evaluation plan and experimental design for determining the effectiveness and usability of ORBIS, a proprietary device for automatically detecting and recording speeding motorists. The experimental evaluation will be conducte...

  7. 77 FR 4252 - Additional Spectrum for the Medical Device Radiocommunication Service

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-27

    ... experimental license from the Commission to operate its devices in the 400-470 MHz band. Alfred Mann's wideband... Administration and other hospitals under its experimental license has proven the potential benefits of MMNs. The... experimental license that it has held since January 2005 and in actual evaluation and testing in cooperation...

  8. Experimental evaluation of a miniature MR device for a wide range of human perceivable haptic sensations

    NASA Astrophysics Data System (ADS)

    Yang, Tae-Heon; Koo, Jeong-Hoi

    2017-12-01

    Humans can experience a realistic and vivid haptic sensations by the sense of touch. In order to have a fully immersive haptic experience, both kinaesthetic and vibrotactile information must be presented to human users. Currently, little haptic research has been performed on small haptic actuators that can covey both vibrotactile feedback based on the frequency of vibrations up to the human-perceivable limit and multiple levels of kinaesthetic feedback rapidly. Therefore, this study intends to design a miniature haptic device based on MR fluid and experimentally evaluate its ability to convey vibrotactile feedback up to 300 Hz along with kinaesthetic feedback. After constructing a prototype device, a series of testing was performed to evaluate its performance of the prototype using an experimental setup, consisting of a precision dynamic mechanical analyzer and an accelerometer. The kinaesthetic testing results show that the prototype device can provide the force rate up to 89% at 5 V (360 mA), which can be discretized into multiple levels of ‘just noticeable difference’ force rate, indicating that the device can convey a wide range of kinaesthetic sensations. To evaluate the high frequency vibrotactile feedback performance of the device, its acceleration responses were measured and processed using the FFT analysis. The results indicate that the device can convey high frequency vibrotactile sensations up to 300 Hz with the sufficiently large intensity of accelerations that human can feel.

  9. An Experimental Database for Conventional and Alternate Control Concepts on the HSR 1.675% Reference H Model

    NASA Technical Reports Server (NTRS)

    McMillin, Naomi; Allen, Jerry; Erickson, Gary; Campbell, Jim; Mann, Mike; Kubiatko, Paul; Yingling, David; Mason, Charlie

    1999-01-01

    The objective was to experimentally evaluate the longitudinal and lateral-directional stability and control characteristics of the Reference H configuration at supersonic and transonic speeds. A series of conventional and alternate control devices were also evaluated at supersonic and transonic speeds. A database on the conventional and alternate control devices was to be created for use in the HSR program.

  10. EVALUATION OF FOUR NOVEL FINE PARTICULATE COLLECTION DEVICES

    EPA Science Inventory

    The report gives results of an experimental performance evaluation of four novel fine particulate control devices: the Johns-Manville Cleanable High-Efficiency Air Filtration (CHEAF) System, the APS Electrostatic Scrubber, the APS Electrotube, and the TRW Charged Droplet Scrubber...

  11. An experimental and theoretical evaluation of increased thermal diffusivity phase change devices

    NASA Technical Reports Server (NTRS)

    White, S. P.; Golden, J. O.; Stermole, F. J.

    1972-01-01

    This study was to experimentally evaluate and mathematically model the performance of phase change thermal control devices containing high thermal conductivity metal matrices. Three aluminum honeycomb filters were evaluated at five different heat flux levels using n-oct-adecane as the test material. The system was mathematically modeled by approximating the partial differential equations with a three-dimensional implicit alternating direction technique. The mathematical model predicts the system quite well. All of the phase change times are predicted. The heating of solid phase is predicted exactly while there is some variation between theoretical and experimental results in the liquid phase. This variation in the liquid phase could be accounted for by the fact that there are some heat losses in the cell and there could be some convection in the experimental system.

  12. TRIANGLE-SHAPED DC CORONA DISCHARGE DEVICE FOR MOLECULAR DECOMPOSITION

    EPA Science Inventory

    The paper discusses the evaluation of electrostatic DC corona discharge devices for the application of molecular decomposition. A point-to-plane geometry corona device with a rectangular cross section demonstrated low decomposition efficiencies in earlier experimental work. The n...

  13. Physical Modeling of the Polyfrequency Filter-Compensating Device Based on the Capacitor-Coil

    NASA Astrophysics Data System (ADS)

    Butyrin, P. A.; Gusev, G. G.; Mikheev, D. V.; Shakirzianov, F. N.

    2017-12-01

    The paper presents the results of physical modeling and experimental study of the frequency characteristics of the polyfrequency filter-compensating device (PFCD) based on a capacitor-coil. The amplitude- frequency and phase-frequency characteristics of the physical PFCD model were constructed and its equivalent parameters were identified. The feasibility of a PFCD in the form of a single technical device with high technical and economic characteristics was experimentally proven. In the paper, recommendations for practical applications of the capacitor-coil-based PFCD are made and the advantages of the device over known standard passive filter-compensating devices are evaluated.

  14. Computer-aided design and experimental investigation of a hydrodynamic device: the microwire electrode

    PubMed

    Fulian; Gooch; Fisher; Stevens; Compton

    2000-08-01

    The development and application of a new electrochemical device using a computer-aided design strategy is reported. This novel design is based on the flow of electrolyte solution past a microwire electrode situated centrally within a large duct. In the design stage, finite element simulations were employed to evaluate feasible working geometries and mass transport rates. The computer-optimized designs were then exploited to construct experimental devices. Steady-state voltammetric measurements were performed for a reversible one-electron-transfer reaction to establish the experimental relationship between electrolysis current and solution velocity. The experimental results are compared to those predicted numerically, and good agreement is found. The numerical studies are also used to establish an empirical relationship between the mass transport limited current and the volume flow rate, providing a simple and quantitative alternative for workers who would prefer to exploit this device without the need to develop the numerical aspects.

  15. Evaluation of high mast luminaire lowering devices in Oregon.

    DOT National Transportation Integrated Search

    1981-09-01

    High mast luminaire lowering devices were installed on two projects in Oregon following approval by the Department of Transportation, Federal Highway Administration, of the installations as experimental features projects. Holophane Company, Inc., sup...

  16. Theoretical and material studies on thin-film electroluminescent devices

    NASA Technical Reports Server (NTRS)

    Summers, C. J.; Brennan, K. F.

    1986-01-01

    Electroluminescent materials and device technology were assessed. The evaluation strongly suggests the need for a comprehensive theoretical and experimental study of both materials and device structures, particularly in the following areas: carrier generation and multiplication; radiative and nonradiative processes of luminescent centers; device modeling; new device concepts; and single crystal materials growth and characterization. Modeling of transport properties of hot electrons in ZnSe and the generation of device concepts were initiated.

  17. Pen Devices for Insulin Self-Administration Compared With Needle and Vial: Systematic Review of the Literature and Meta-Analysis.

    PubMed

    Lasalvia, Pieralessandro; Barahona-Correa, Julián Esteban; Romero-Alvernia, Diana Marcela; Gil-Tamayo, Sebastián; Castañeda-Cardona, Camilo; Bayona, Juan Gabriel; Triana, Juan José; Laserna, Andrés Felipe; Mejía-Torres, Miguel; Restrepo-Jimenez, Paula; Jimenez-Zapata, Juliana; Rosselli, Diego

    2016-07-01

    Pen devices offer advantages compared with vial and syringe (VaS). The purpose of this article was to evaluate efficacy of pen devices compared to VaS. A systematic review of literature was performed in 8 different databases. References were independently screened and selected. Primary observational or experimental studies comparing pen devices with VaS for insulin administrations were included. Studies on specific populations were excluded. Risk of bias was evaluated using appropriate tools. Data on glycosylated hemoglobin (HbA1c), hypoglycemia, adherence, persistence, patient preference, and quality of life (QOL) were collected. Meta-analysis was performed when appropriate. Heterogeneity and risk of publication bias were evaluated. Otherwise, descriptive analyses of the available data was done. In all, 10 348 articles were screened. A total of 17 studies were finally selected: 7 experimental and 10 analytical. The populations of the included articles were mainly composed of adults with type 2 diabetes mellitus. Important risk of bias was found in all of the articles, particularly experimental studies. Meta-analyses were performed for HbA1c, hypoglycemia, adherence and persistence. Pen device showed better results in mean HbA1c change, patients with hypoglycemia, adherence and persistence compared to VaS. No difference was observed in number of patients achieving <7% HbA1c. Preference studies showed a tendency favoring pen devices, however nonvalidated tools were used. One QoL study showed improvements in some subscales of SF-36. There is evidence that pen devices offer benefits in clinical and, less clearly, patient-reported outcomes compared to VaS for insulin administration. However, these results should be taken with caution. © 2016 Diabetes Technology Society.

  18. Experimental traffic control device testing at New Hampshire toll plazas.

    DOT National Transportation Integrated Search

    2007-06-01

    This report includes a description of the testing and evaluation methodology of the E-ZPassSM Purple Light Experiment. Purple lights with : advanced signs were installed as supplemental traffic control devices for northbound and southbound E-Zp...

  19. Sharing Data between Mobile Devices, Connected Vehicles and Infrastructure Task 8 : D2X Hub Proof-of-Concept Test Evaluation Report.

    DOT National Transportation Integrated Search

    2017-10-25

    The Task 8 D2X Hub Proof-of-Concept Test Evaluation Report provides results of the experimental data analysis performed in accordance with the experimental plan for the proof-of-concept version of the prototype system. The data set analyzed includes ...

  20. Investigation of multilayer magnetic domain lattice file

    NASA Technical Reports Server (NTRS)

    Torok, E. J.; Kamin, M.; Tolman, C. H.

    1982-01-01

    A theoretical and experimental investigation determined that current accessed self structured bubble memory devices have the potential of meeting projected data density and speed requirements. Device concepts analyzed include multilayer ferrimagnetic devices where the top layer contains a domain structure which defines the data location and the second contains the data. Current aperture and permalloy assisted current propagation devices were evaluated. Based on the result of this work more detailed device research was initiated. Detailed theoretical and experimental studies indicate that the difference in strip and threshold between a single bubble in the control layer and a double bubble which would exist in both the control layer and data layer is adequate to allow for detection of data. Detailed detector designs were investigated.

  1. Experimental Evaluation of Unicast and Multicast CoAP Group Communication

    PubMed Central

    Ishaq, Isam; Hoebeke, Jeroen; Moerman, Ingrid; Demeester, Piet

    2016-01-01

    The Internet of Things (IoT) is expanding rapidly to new domains in which embedded devices play a key role and gradually outnumber traditionally-connected devices. These devices are often constrained in their resources and are thus unable to run standard Internet protocols. The Constrained Application Protocol (CoAP) is a new alternative standard protocol that implements the same principals as the Hypertext Transfer Protocol (HTTP), but is tailored towards constrained devices. In many IoT application domains, devices need to be addressed in groups in addition to being addressable individually. Two main approaches are currently being proposed in the IoT community for CoAP-based group communication. The main difference between the two approaches lies in the underlying communication type: multicast versus unicast. In this article, we experimentally evaluate those two approaches using two wireless sensor testbeds and under different test conditions. We highlight the pros and cons of each of them and propose combining these approaches in a hybrid solution to better suit certain use case requirements. Additionally, we provide a solution for multicast-based group membership management using CoAP. PMID:27455262

  2. Purple dots phase II.

    DOT National Transportation Integrated Search

    2012-06-01

    On behalf of the Maryland Transportation Authority (MDTA), Kittelson & Associates, Inc. : (KAI) is conducting an evaluation of an experimental traffic control device at a Maryland toll : plaza. This report summarizes our findings for the evaluation o...

  3. A 3-RSR Haptic Wearable Device for Rendering Fingertip Contact Forces.

    PubMed

    Leonardis, Daniele; Solazzi, Massimiliano; Bortone, Ilaria; Frisoli, Antonio

    2017-01-01

    A novel wearable haptic device for modulating contact forces at the fingertip is presented. Rendering of forces by skin deformation in three degrees of freedom (DoF), with contact-no contact capabilities, was implemented through rigid parallel kinematics. The novel asymmetrical three revolute-spherical-revolute (3-RSR) configuration allowed compact dimensions with minimum encumbrance of the hand workspace. The device was designed to render constant to low frequency deformation of the fingerpad in three DoF, combining light weight with relatively high output forces. A differential method for solving the non-trivial inverse kinematics is proposed and implemented in real time for controlling the device. The first experimental activity evaluated discrimination of different fingerpad stretch directions in a group of five subjects. The second experiment, enrolling 19 subjects, evaluated cutaneous feedback provided in a virtual pick-and-place manipulation task. Stiffness of the fingerpad plus device was measured and used to calibrate the physics of the virtual environment. The third experiment with 10 subjects evaluated interaction forces in a virtual lift-and-hold task. Although with different performance in the two manipulation experiments, overall results show that participants better controlled interaction forces when the cutaneous feedback was active, with significant differences between the visual and visuo-haptic experimental conditions.

  4. Comparison of mercury retention by fly ashes using different experimental devices

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lopez-Anton, M.A.; Abad-Valle, P.; Diaz-Somoano, M.

    2009-12-15

    To study mercury (Hg) retention in solid sorbents, researchers generally employ similar laboratory-scale devices. However, despite their similarities, these devices are generally used under different experimental conditions. The Hg concentration in the gas phase, gas flow, and sorbent-bed characteristics are variables that influence the contact time, mass transfer, and kinetics and may greatly modify the quantities of Hg retained when the same sorbents are compared. These differences in the experimental conditions do not impede an evaluation of the sorbents as long as the results obtained points toward the same qualitative conclusions. However, the extent of variation needs to be definedmore » to avoid misinterpretation. To illustrate the range of interpretations, the results of a preliminary approach using four experimental devices in two laboratories have been compared in this work. All the experiments were carried out under a nitrogen atmosphere and Hg{sup 0} in the gas phase. The same sorbents were employed in all the devices. These were fly ashes obtained from the combustion of coals of different rank and with different unburned carbon contents. From the results obtained it can be inferred that it is necessary to strictly control the influence of the experimental variables to infer a correct interpretation of the results.« less

  5. 5 CFR 595.103 - What requirements must agencies establish for determining which physician positions are covered?

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... research and experimental work, including the conduct of medical work pertaining to food, drugs, cosmetics, and devices (or the review or evaluation of such medical research and experimental work), or the... medical research and experimental programs. (c) The agency head may establish as separate categories any...

  6. 5 CFR 595.103 - What requirements must agencies establish for determining which physician positions are covered?

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... research and experimental work, including the conduct of medical work pertaining to food, drugs, cosmetics, and devices (or the review or evaluation of such medical research and experimental work), or the... medical research and experimental programs. (c) The agency head may establish as separate categories any...

  7. 5 CFR 595.103 - What requirements must agencies establish for determining which physician positions are covered?

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... research and experimental work, including the conduct of medical work pertaining to food, drugs, cosmetics, and devices (or the review or evaluation of such medical research and experimental work), or the... medical research and experimental programs. (c) The agency head may establish as separate categories any...

  8. 5 CFR 595.103 - What requirements must agencies establish for determining which physician positions are covered?

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... research and experimental work, including the conduct of medical work pertaining to food, drugs, cosmetics, and devices (or the review or evaluation of such medical research and experimental work), or the... medical research and experimental programs. (c) The agency head may establish as separate categories any...

  9. Survey and Experimental Testing of Nongravimetric Mass Measurement Devices

    NASA Technical Reports Server (NTRS)

    Oakey, W. E.; Lorenz, R.

    1977-01-01

    Documentation presented describes the design, testing, and evaluation of an accelerated gravimetric balance, a low mass air bearing oscillator of the spring-mass type, and a centrifugal device for liquid mass measurement. A direct mass readout method was developed to replace the oscillation period readout method which required manual calculations to determine mass. A protoype 25 gram capacity micro mass measurement device was developed and tested.

  10. On the design of a miniature haptic ring for cutaneous force feedback using shape memory alloy actuators

    NASA Astrophysics Data System (ADS)

    Hwang, Donghyun; Lee, Jaemin; Kim, Keehoon

    2017-10-01

    This paper proposes a miniature haptic ring that can display touch/pressure and shearing force to the user’s fingerpad. For practical use and wider application of the device, it is developed with the aim of achieving high wearability and mobility/portability as well as cutaneous force feedback functionality. A main body of the device is designed as a ring-shaped lightweight structure with a simple driving mechanism, and thin shape memory alloy (SMA) wires having high energy density are applied as actuating elements. Also, based on a band-type wireless control unit including a wireless data communication module, the whole device could be realized as a wearable mobile haptic device system. These features enable the device to take diverse advantages on functional performances and to provide users with significant usability. In this work, the proposed miniature haptic ring is systematically designed, and its working performances are experimentally evaluated with a fabricated functional prototype. The experimental results obviously demonstrate that the proposed device exhibits higher force-to-weight ratio than conventional finger-wearable haptic devices for cutaneous force feedback. Also, it is investigated that operational performances of the device are strongly influenced by electro-thermomechanical behaviors of the SMA actuator. In addition to the experiments for performance evaluation, we conduct a preliminary user test to assess practical feasibility and usability based on user’s qualitative feedback.

  11. Numerical and experimental evaluation of microfluidic sorting devices.

    PubMed

    Taylor, Jay K; Ren, Carolyn L; Stubley, G D

    2008-01-01

    The development of lab-on-a-chip devices calls for the isolation or separation of specific bioparticles or cells. The design of a miniaturized cell-sorting device for handheld operation must follow the strict parameters associated with lab-on-a-chip technology. The limitations include applied voltage, high efficiency of cell-separation, reliability, size, flow control, and cost, among others. Currently used designs have achieved successful levels of cell isolation; however, further improvements in the microfluidic chip design are important to incorporate into larger systems. This study evaluates specific design modifications that contribute to the reduction of required applied potential aiming for developing portable devices, improved operation reliability by minimizing induced pressure disturbance when electrokinetic pumping is employed, and improved flow control by incorporating directing streams achieving dynamic sorting and counting. The chip designs fabricated in glass and polymeric materials include asymmetric channel widths for sample focusing, nonuniform channel depth for minimizing induced pressure disturbance, directing streams to assist particle flow control, and online filters for reducing channel blockage. Fluorescence-based visualization experimental results of electrokinetic focusing, flow field phenomena, and dynamic sorting demonstrate the advantages of the chip design. Numerical simulations in COMSOL are validated by the experimental data and used to investigate the effects of channel geometry and fluid properties on the flow field.

  12. Topical review: spins and mechanics in diamond

    NASA Astrophysics Data System (ADS)

    Lee, Donghun; Lee, Kenneth W.; Cady, Jeffrey V.; Ovartchaiyapong, Preeti; Bleszynski Jayich, Ania C.

    2017-03-01

    There has been rapidly growing interest in hybrid quantum devices involving a solid-state spin and a macroscopic mechanical oscillator. Such hybrid devices create exciting opportunities to mediate interactions between disparate quantum bits (qubits) and to explore the quantum regime of macroscopic mechanical objects. In particular, a system consisting of the nitrogen-vacancy defect center (NV center) in diamond coupled to a high-quality-factor mechanical oscillator is an appealing candidate for such a hybrid quantum device, as it utilizes the highly coherent and versatile spin properties of the defect center. In this paper, we will review recent experimental progress on diamond-based hybrid quantum devices in which the spin and orbital dynamics of single defects are driven by the motion of a mechanical oscillator. In addition, we discuss prospective applications for this device, including long-range, phonon-mediated spin-spin interactions, and phonon cooling in the quantum regime. We conclude the review by evaluating the experimental limitations of current devices and identifying alternative device architectures that may reach the strong coupling regime.

  13. Experimental evaluations of wearable ECG monitor.

    PubMed

    Ha, Kiryong; Kim, Youngsung; Jung, Junyoung; Lee, Jeunwoo

    2008-01-01

    Healthcare industry is changing with ubiquitous computing environment and wearable ECG measurement is one of the most popular approaches in this healthcare industry. Reliability and performance of healthcare device is fundamental issue for widespread adoptions, and interdisciplinary perspectives of wearable ECG monitor make this more difficult. In this paper, we propose evaluation criteria considering characteristic of both ECG measurement and ubiquitous computing. With our wearable ECG monitors, various levels of experimental analysis are performed based on evaluation strategy.

  14. Evaluation of the ruggedness of power DMOS transistor from electro-thermal simulation of UIS behaviour

    NASA Astrophysics Data System (ADS)

    Donoval, Daniel; Vrbicky, Andrej; Marek, Juraj; Chvala, Ales; Beno, Peter

    2008-06-01

    High-voltage power MOSFETs have been widely used in switching mode power supply circuits as output drivers for industrial and automotive electronic control systems. However, as the device size is reduced, the energy handling capability is becoming a very important issue to be addressed together with the trade-off between the series on-resistance RON and breakdown voltage VBR. Unclamped inductive switching (UIS) condition represents the circuit switching operation for evaluating the "ruggedness", which characterizes the device capability to handle high avalanche currents during the applied stress. In this paper we present an experimental method which modifies the standard UIS test and allows extraction of the maximum device temperature after the applied standard stress pulse vanishes. Corresponding analysis and non-destructive prediction of the ruggedness of power DMOSFETs devices supported by advanced 2-D mixed mode electro-thermal device and circuit simulation under UIS conditions using calibrated physical models is provided also. The results of numerical simulation are in a very good correlation with experimental characteristics and contribute to their physical interpretation by identification of the mechanism of heat generation and heat source location and continuous temperature extraction.

  15. A magnetorheological haptic cue accelerator for manual transmission vehicles

    NASA Astrophysics Data System (ADS)

    Han, Young-Min; Noh, Kyung-Wook; Lee, Yang-Sub; Choi, Seung-Bok

    2010-07-01

    This paper proposes a new haptic cue function for manual transmission vehicles to achieve optimal gear shifting. This function is implemented on the accelerator pedal by utilizing a magnetorheological (MR) brake mechanism. By combining the haptic cue function with the accelerator pedal, the proposed haptic cue device can transmit the optimal moment of gear shifting for manual transmission to a driver without requiring the driver's visual attention. As a first step to achieve this goal, a MR fluid-based haptic device is devised to enable rotary motion of the accelerator pedal. Taking into account spatial limitations, the design parameters are optimally determined using finite element analysis to maximize the relative control torque. The proposed haptic cue device is then manufactured and its field-dependent torque and time response are experimentally evaluated. Then the manufactured MR haptic cue device is integrated with the accelerator pedal. A simple virtual vehicle emulating the operation of the engine of a passenger vehicle is constructed and put into communication with the haptic cue device. A feed-forward torque control algorithm for the haptic cue is formulated and control performances are experimentally evaluated and presented in the time domain.

  16. Capillary acquisition devices for high-performance vehicles: Executive summary. [evaluation of cryogenic propellant management techniques using the centaur launch vehicle

    NASA Technical Reports Server (NTRS)

    Blatt, M. H.; Bradshaw, R. D.; Risberg, J. A.

    1980-01-01

    Technology areas critical to the development of cryogenic capillary devices were studied. Passive cooling of capillary devices was investigated with an analytical and experimental study of wicking flow. Capillary device refilling with settled fluid was studied using an analytical and experimental program that resulted in successful correlation of a versatile computer program with test data. The program was used to predict Centaur D-1S LO2 and LH2 start basket refilling. Comparisons were made between the baseline Centaur D-1S propellant feed system and feed system alternatives including systems using capillary devices. The preferred concepts from the Centaur D-1S study were examined for APOTV and POTV vehicles for delivery and round trip transfer of payloads between LEO and GEO. Mission profiles were determined to provide propellant usage timelines and the payload partials were defined.

  17. Experimental determination of the PTW 60019 microDiamond dosimeter active area and volume

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marinelli, Marco, E-mail: marco.marinelli@uniroma2

    Purpose: Small field output correction factors have been studied by several research groups for the PTW 60019 microDiamond (MD) dosimeter, by comparing the response of such a device with both reference dosimeters and Monte Carlo simulations. A general good agreement is observed for field sizes down to about 1 cm. However, evident inconsistencies can be noticed when comparing some experimental results and Monte Carlo simulations obtained for smaller irradiation fields. This issue was tentatively attributed by some authors to unintentional large variations of the MD active surface area. The aim of the present study is a nondestructive experimental determination ofmore » the MD active surface area and active volume. Methods: Ten MD dosimeters, one MD prototype, and three synthetic diamond samples were investigated in the present work. 2D maps of the MD response were recorded under scanned soft x-ray microbeam irradiation, leading to an experimental determination of the device active surface area. Profiles of the device responses were measured as well. In order to evaluate the MD active volume, the thickness of the diamond sensing layer was independently evaluated by capacitance measurements and alpha particle detection experiments. The MD sensitivity, measured at the PTW calibration laboratory, was also used to calculate the device active volume thickness. Results: An average active surface area diameter of (2.19 ± 0.02) mm was evaluated by 2D maps and response profiles of all the MDs. Average active volume thicknesses of (1.01 ± 0.13) μm and (0.97 ± 0.14) μm were derived by capacitance and sensitivity measurements, respectively. The obtained results are well in agreement with the nominal values reported in the manufacturer dosimeter specifications. A homogeneous response was observed over the whole device active area. Besides the one from the device active volume, no contributions from other components of the housing nor from encapsulation materials were observed in the 2D response maps. Conclusions: The obtained results demonstrate the high reproducibility of the MD fabrication process. The observed discrepancies among the output correction factors reported by several authors for MD response in very small fields are very unlikely to be ascribed to unintentional variations of the device active surface area and volume. It is the opinion of the authors that the role of the volume averaging as well as of other perturbation effects should be separately investigated instead, both experimentally and by Monte Carlo simulations, in order to better clarify the behaviour of the MD response in very small fields.« less

  18. The Centrifugal Simulation of Blast Parameters.

    DTIC Science & Technology

    1983-12-01

    a is to be experimentally evaluated. The terms that remain in Equation (1) are not nondimensional; that is, they are not true i-terms. This does not...If necessary and identify by block number This study is concerned with the use oT a centrifuge as an experimental device on which free-field blast...5 SIMILITUDE. .. .. ..... ...... ...... ... 9 Ill. EXPERIMENTAL PROCEDURES .. .. ... ...... ........13 INTRODUCTION

  19. Experimental evaluation of dual multiple aperture devices for fluence field modulated x-ray computed tomography

    NASA Astrophysics Data System (ADS)

    Mathews, A. J.; Gang, G.; Levinson, R.; Zbijewski, W.; Kawamoto, S.; Siewerdsen, J. H.; Stayman, J. W.

    2017-03-01

    Acquisition of CT images with comparable diagnostic power can potentially be achieved with lower radiation exposure than the current standard of care through the adoption of hardware-based fluence-field modulation (e.g. dynamic bowtie filters). While modern CT scanners employ elements such as static bowtie filters and tube-current modulation, such solutions are limited in the fluence patterns that they can achieve, and thus are limited in their ability to adapt to broad classes of patient morphology. Fluence-field modulation also enables new applications such as region-of-interest imaging, task specific imaging, reducing measurement noise or improving image quality. The work presented in this paper leverages a novel fluence modulation strategy that uses "Multiple Aperture Devices" (MADs) which are, in essence, binary filters, blocking or passing x-rays on a fine scale. Utilizing two MAD devices in series provides the capability of generating a large number of fluence patterns via small relative motions between the MAD filters. We present the first experimental evaluation of fluence-field modulation using a dual-MAD system, and demonstrate the efficacy of this technique with a characterization of achievable fluence patterns and an investigation of experimental projection data.

  20. Evaluation of thermal gradients in longitudinal spin Seebeck effect measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sola, A., E-mail: a.sola@inrim.it; Kuepferling, M.; Basso, V.

    2015-05-07

    In the framework of the longitudinal spin Seebeck effect (LSSE), we developed an experimental setup for the characterization of LSSE devices. This class of device consists in a layered structure formed by a substrate, a ferrimagnetic insulator (YIG) where the spin current is thermally generated, and a paramagnetic metal (Pt) for the detection of the spin current via the inverse spin-Hall effect. In this kind of experiments, the evaluation of a thermal gradient through the thin YIG layer is a crucial point. In this work, we perform an indirect determination of the thermal gradient through the measurement of the heatmore » flux. We developed an experimental setup using Peltier cells that allow us to measure the heat flux through a given sample. In order to test the technique, a standard LSSE device produced at Tohoku University was measured. We find a spin Seebeck S{sub SSE} coefficient of 2.8×10{sup −7} V K{sup −1}.« less

  1. Performance of ZnO based piezo-generators under controlled compression

    NASA Astrophysics Data System (ADS)

    Tao, Ran; Parmar, Mitesh; Ardila, Gustavo; Oliveira, Paulo; Marques, Daniel; Montès, Laurent; Mouis, Mireille

    2017-06-01

    This paper reports on the fabrication and characterization of ZnO based vertically integrated nanogenerator (VING) devices under controlled compression. The basic NG structure is a composite material integrating hydrothermally grown vertical piezoelectric zinc oxide (ZnO) nanowires (NWs) into a dielectric matrix (PMMA). A specific characterization set-up has been developed to control the applied compression and the perpendicularity of the applied force on the devices. The role of different fabrication parameters has been evaluated experimentally and compared with previously reported theoretical models, including the thickness of the top PMMA layer and the density of the NWs array in the matrix. Finally, the performance of the VING structure has been evaluated experimentally for different resistive loads obtaining a power density of 85 μW cm-3 considering only the active layer of the device. This has been compared to the performance of a commercial bulk layer of PZT (25 μW cm-3) under the same applied force of 5 N.

  2. A new adjustable parallel drill guide for internal fixation of femoral neck fracture: a developmental and experimental study.

    PubMed

    Yuenyongviwat, Varah; Tuntarattanapong, Pakjai; Tangtrakulwanich, Boonsin

    2016-01-11

    Internal fixation is one treatment for femoral neck fracture. Some devices and techniques reported improved accuracy and decreased fluoroscopic time. However, these are not widely used nowadays due to the lack of available special instruments and techniques. To improve the surgical procedure, the authors designed a new adjustable drill guide and tested the efficacy of the device. The authors developed a new adjustable drill guide for cannulated screw guide wire insertion for multiple screw fixation. Eight orthopaedic surgeons performed the experimental study to evaluate the efficacy of this device. Each surgeon performed guide wire insertion for multiple screw fixation in six synthetic femurs: three times with the new device and three times with the conventional technique. The fluoroscopic time, operative time and surgeon satisfaction were evaluated. In the operations with the new adjustable drill guide, the fluoroscopic and operative times were significantly lower than the operations with the conventional technique (p < 0.05). The mean score for the level of satisfaction of this device was also statistically significantly better (p = 0.02) than the conventional technique. The fluoroscopic and operative times with the new adjustable drill guide were reduced for multiple screw fixation of femoral neck fracture and the satisfaction of the surgeons was good.

  3. Ex vivo study of the home-use TriPollar RF device using an experimental human skin model.

    PubMed

    Boisnic, Sylvie; Branchet, Marie Christine

    2010-09-01

    A wide variety of professional radio frequency (RF) aesthetic treatments for anti-aging are available aiming at skin tightening. A new home-use RF device for facial treatments has recently been developed based on TriPollar technology. To evaluate the mechanism of the new home-use device, in the process of collagen remodeling, using an ex vivo skin model. Human skin samples were collected in order to evaluate the anti-aging effect of a home-use device for facial treatments on an ex vivo human skin model. Skin tightening was evaluated by dermal histology, quantitative analysis of collagen fibers and dosage of collagen synthesis. Significant collagen remodeling following RF treatment with the device was found in the superficial and mid-deep dermis. Biochemical measurement of newly synthesized collagen showed an increase of 41% in the treated samples as compared to UV-aged control samples. The new home-use device has been demonstrated to affect significant collagen remodeling, in terms of the structural and biochemical improvement of dermal collagen on treated skin samples.

  4. Comparative analysis of international standards for the fatigue testing of posterior spinal fixation systems.

    PubMed

    Villa, Tomaso; La Barbera, Luigi; Galbusera, Fabio

    2014-04-01

    Preclinical evaluation of the long-term reliability of devices for lumbar fixation is a mandatory activity before they are put into market. The experimental setups are described in two different standards edited by the International Organization for Standardization (ISO) and the American Society for Testing Materials (ASTM), but the evaluation of the suitability of such tests to simulate the actual loading with in vivo situations has never been performed. To calculate through finite element (FE) simulations the stress in the rods of the fixator when subjected to ASTM and ISO standards. To compare the calculated stresses arising in the same fixator once it has been virtually mounted in a physiological environment and loaded with physiological forces and moments. FE simulations and validation experimental tests. FE models of the ISO and ASTM setups were created to conduct simulations of the tests prescribed by standards and calculate stresses in the rods. Validation of the simulations were performed through experimental tests; the same fixator was virtually mounted in an L2-L4 FE model of the lumbar spine and stresses in the rods were calculated when the spine was subjected to physiological forces and moments. The comparison between FE simulations and experimental tests showed good agreement between results obtained using the two methodologies, thus confirming the suitability of the FE method to evaluate stresses in the device in different loading situations. The usage of a physiological load with ASTM standard is impossible due to the extreme severity of the ASTM configuration; in this circumstance, the presence of an anterior support is suggested. Also, ISO prescriptions, although the choice of the setup correctly simulates the mechanical contribution of the discs, seem to overstress the device as compared with a physiological loading condition. Some daily activities, other than walking, can induce a further state of stress in the device that should be taken into account in setting up new experimental procedures. ISO standard loading prescriptions seems to be more severe than the expected physiological ones. The ASTM standard should be completed by including some anterior supporting device and declaring the value of the load to be imposed. Moreover, a further enhancement of standards would be simulating other movements representative of daily activities different from walking. Copyright © 2014 Elsevier Inc. All rights reserved.

  5. Proposal and Evaluation of BLE Discovery Process Based on New Features of Bluetooth 5.0.

    PubMed

    Hernández-Solana, Ángela; Perez-Diaz-de-Cerio, David; Valdovinos, Antonio; Valenzuela, Jose Luis

    2017-08-30

    The device discovery process is one of the most crucial aspects in real deployments of sensor networks. Recently, several works have analyzed the topic of Bluetooth Low Energy (BLE) device discovery through analytical or simulation models limited to version 4.x. Non-connectable and non-scannable undirected advertising has been shown to be a reliable alternative for discovering a high number of devices in a relatively short time period. However, new features of Bluetooth 5.0 allow us to define a variant on the device discovery process, based on BLE scannable undirected advertising events, which results in higher discovering capacities and also lower power consumption. In order to characterize this new device discovery process, we experimentally model the real device behavior of BLE scannable undirected advertising events. Non-detection packet probability, discovery probability, and discovery latency for a varying number of devices and parameters are compared by simulations and experimental measurements. We demonstrate that our proposal outperforms previous works, diminishing the discovery time and increasing the potential user device density. A mathematical model is also developed in order to easily obtain a measure of the potential capacity in high density scenarios.

  6. Proposal and Evaluation of BLE Discovery Process Based on New Features of Bluetooth 5.0

    PubMed Central

    2017-01-01

    The device discovery process is one of the most crucial aspects in real deployments of sensor networks. Recently, several works have analyzed the topic of Bluetooth Low Energy (BLE) device discovery through analytical or simulation models limited to version 4.x. Non-connectable and non-scannable undirected advertising has been shown to be a reliable alternative for discovering a high number of devices in a relatively short time period. However, new features of Bluetooth 5.0 allow us to define a variant on the device discovery process, based on BLE scannable undirected advertising events, which results in higher discovering capacities and also lower power consumption. In order to characterize this new device discovery process, we experimentally model the real device behavior of BLE scannable undirected advertising events. Non-detection packet probability, discovery probability, and discovery latency for a varying number of devices and parameters are compared by simulations and experimental measurements. We demonstrate that our proposal outperforms previous works, diminishing the discovery time and increasing the potential user device density. A mathematical model is also developed in order to easily obtain a measure of the potential capacity in high density scenarios. PMID:28867786

  7. SHORT COMMUNICATION: Time measurement device with four femtosecond stability

    NASA Astrophysics Data System (ADS)

    Panek, Petr; Prochazka, Ivan; Kodet, Jan

    2010-10-01

    We present the experimental results of extremely precise timing in the sense of time-of-arrival measurements in a local time scale. The timing device designed and constructed in our laboratory is based on a new concept using a surface acoustic wave filter as a time interpolator. Construction of the device is briefly described. The experiments described were focused on evaluating the timing precision and stability. Low-jitter test pulses with a repetition frequency of 763 Hz were generated synchronously to the local time base and their times of arrival were measured. The resulting precision of a single measurement was typically 900 fs RMS, and a timing stability TDEV of 4 fs was achieved for time intervals in the range from 300 s to 2 h. To our knowledge this is the best value reported to date for the stability of a timing device. The experimental results are discussed and possible improvements are proposed.

  8. A novel method for the accurate evaluation of Poisson's ratio of soft polymer materials.

    PubMed

    Lee, Jae-Hoon; Lee, Sang-Soo; Chang, Jun-Dong; Thompson, Mark S; Kang, Dong-Joong; Park, Sungchan; Park, Seonghun

    2013-01-01

    A new method with a simple algorithm was developed to accurately measure Poisson's ratio of soft materials such as polyvinyl alcohol hydrogel (PVA-H) with a custom experimental apparatus consisting of a tension device, a micro X-Y stage, an optical microscope, and a charge-coupled device camera. In the proposed method, the initial positions of the four vertices of an arbitrarily selected quadrilateral from the sample surface were first measured to generate a 2D 1st-order 4-node quadrilateral element for finite element numerical analysis. Next, minimum and maximum principal strains were calculated from differences between the initial and deformed shapes of the quadrilateral under tension. Finally, Poisson's ratio of PVA-H was determined by the ratio of minimum principal strain to maximum principal strain. This novel method has an advantage in the accurate evaluation of Poisson's ratio despite misalignment between specimens and experimental devices. In this study, Poisson's ratio of PVA-H was 0.44 ± 0.025 (n = 6) for 2.6-47.0% elongations with a tendency to decrease with increasing elongation. The current evaluation method of Poisson's ratio with a simple measurement system can be employed to a real-time automated vision-tracking system which is used to accurately evaluate the material properties of various soft materials.

  9. Comparative evaluation of user interfaces for robot-assisted laser phonomicrosurgery.

    PubMed

    Dagnino, Giulio; Mattos, Leonardo S; Becattini, Gabriele; Dellepiane, Massimo; Caldwell, Darwin G

    2011-01-01

    This research investigates the impact of three different control devices and two visualization methods on the precision, safety and ergonomics of a new medical robotic system prototype for assistive laser phonomicrosurgery. This system allows the user to remotely control the surgical laser beam using either a flight simulator type joystick, a joypad, or a pen display system in order to improve the traditional surgical setup composed by a mechanical micromanipulator coupled with a surgical microscope. The experimental setup and protocol followed to obtain quantitative performance data from the control devices tested are fully described here. This includes sets of path following evaluation experiments conducted with ten subjects with different skills, for a total of 700 trials. The data analysis method and experimental results are also presented, demonstrating an average 45% error reduction when using the joypad and up to 60% error reduction when using the pen display system versus the standard phonomicrosurgery setup. These results demonstrate the new system can provide important improvements in terms of surgical precision, ergonomics and safety. In addition, the evaluation method presented here is shown to support an objective selection of control devices for this application.

  10. PVDF Sensor Stimulated by Infrared Radiation for Temperature Monitoring in Microfluidic Devices.

    PubMed

    Pullano, Salvatore A; Mahbub, Ifana; Islam, Syed K; Fiorillo, Antonino S

    2017-04-13

    This paper presents a ferroelectric polymer-based temperature sensor designed for microfluidic devices. The integration of the sensor into a system-on-a-chip platform facilitates quick monitoring of localized temperature of a biological fluid, avoiding errors in the evaluation of thermal evolution of the fluid during analysis. The contact temperature sensor is fabricated by combining a thin pyroelectric film together with an infrared source, which stimulates the active element located on the top of the microfluidic channel. An experimental setup was assembled to validate the analytical model and to characterize the response rate of the device. The evaluation procedure and the operating range of the temperature also make this device suitable for applications where the localized temperature monitoring of biological samples is necessary. Additionally, ease of integration with standard microfluidic devices makes the proposed sensor an attractive option for in situ analysis of biological fluids.

  11. Analytical and Experimental Performance Evaluation of BLE Neighbor Discovery Process Including Non-Idealities of Real Chipsets

    PubMed Central

    Perez-Diaz de Cerio, David; Hernández, Ángela; Valenzuela, Jose Luis; Valdovinos, Antonio

    2017-01-01

    The purpose of this paper is to evaluate from a real perspective the performance of Bluetooth Low Energy (BLE) as a technology that enables fast and reliable discovery of a large number of users/devices in a short period of time. The BLE standard specifies a wide range of configurable parameter values that determine the discovery process and need to be set according to the particular application requirements. Many previous works have been addressed to investigate the discovery process through analytical and simulation models, according to the ideal specification of the standard. However, measurements show that additional scanning gaps appear in the scanning process, which reduce the discovery capabilities. These gaps have been identified in all of the analyzed devices and respond to both regular patterns and variable events associated with the decoding process. We have demonstrated that these non-idealities, which are not taken into account in other studies, have a severe impact on the discovery process performance. Extensive performance evaluation for a varying number of devices and feasible parameter combinations has been done by comparing simulations and experimental measurements. This work also includes a simple mathematical model that closely matches both the standard implementation and the different chipset peculiarities for any possible parameter value specified in the standard and for any number of simultaneous advertising devices under scanner coverage. PMID:28273801

  12. Analytical and Experimental Performance Evaluation of BLE Neighbor Discovery Process Including Non-Idealities of Real Chipsets.

    PubMed

    Perez-Diaz de Cerio, David; Hernández, Ángela; Valenzuela, Jose Luis; Valdovinos, Antonio

    2017-03-03

    The purpose of this paper is to evaluate from a real perspective the performance of Bluetooth Low Energy (BLE) as a technology that enables fast and reliable discovery of a large number of users/devices in a short period of time. The BLE standard specifies a wide range of configurable parameter values that determine the discovery process and need to be set according to the particular application requirements. Many previous works have been addressed to investigate the discovery process through analytical and simulation models, according to the ideal specification of the standard. However, measurements show that additional scanning gaps appear in the scanning process, which reduce the discovery capabilities. These gaps have been identified in all of the analyzed devices and respond to both regular patterns and variable events associated with the decoding process. We have demonstrated that these non-idealities, which are not taken into account in other studies, have a severe impact on the discovery process performance. Extensive performance evaluation for a varying number of devices and feasible parameter combinations has been done by comparing simulations and experimental measurements. This work also includes a simple mathematical model that closely matches both the standard implementation and the different chipset peculiarities for any possible parameter value specified in the standard and for any number of simultaneous advertising devices under scanner coverage.

  13. Experimental study of delta wing leading-edge devices for drag reduction at high lift

    NASA Technical Reports Server (NTRS)

    Johnson, T. D., Jr.; Rao, D. M.

    1982-01-01

    The drag reduction devices selected for evaluation were the fence, slot, pylon-type vortex generator, and sharp leading-edge extension. These devices were tested on a 60 degree flatplate delta (with blunt leading edges) in the Langley Research Center 7- by 10-foot high-speed tunnel at low speed and to angles of attack of 28 degrees. Balance and static pressure measurements were taken. The results indicate that all the devices had significant drag reduction capability and improved longitudinal stability while a slight loss of lift and increased cruise drag occurred.

  14. External osteotomy in rhinoplasty: Piezosurgery vs osteotome.

    PubMed

    Tirelli, Giancarlo; Tofanelli, Margherita; Bullo, Federica; Bianchi, Max; Robiony, Massimo

    2015-01-01

    To achieve the desired outcome in rhinoplasty depends on many factors. Osteotomy and surgical reshaping of nasal bones are important steps that require careful planning and execution. The availability of different tools raises the question of which one provides significant advantages for both technique and surgical outcome. Our prospective randomized pilot study compared the outcome of post-traumatic rhinoplasty performed with two different external techniques: ultrasound osteotomic cut using the Piezosurgery Medical Device (Mectron, Carasco, Italy) and traditional external osteotomy. Forty-four lateral osteotomies of the nasal wall were performed in twenty-two patients. In twelve patients the osteotomies were conducted with a 2-mm traditional osteotome (control group), while in the remaining ten patients these were done with the Piezosurgery Medical Device (experimental group). At the postoperative evaluation, significantly lower pain, edema and ecchymosis were noticed in the experimental group (p<0.05). Moreover, the endoscopic evaluation showed fewer mucosal injuries in the experimental group (p<0.05), whereas bleeding, symmetry of the pyramid and presence of external scars, were similar in the two groups. In the present study, Piezosurgery Medical Device allowed for safe lateral osteotomies in rhinoplasty preliminarily demonstrating the potential to reduce some of the most frequent complications of rhinoplasty. Copyright © 2015 Elsevier Inc. All rights reserved.

  15. Modeling reacting gases and aftertreatment devices for internal combustion engines

    NASA Astrophysics Data System (ADS)

    Depcik, Christopher David

    As more emphasis is placed worldwide on reducing greenhouse gas emissions, automobile manufacturers have to create more efficient engines. Simultaneously, legislative agencies want these engines to produce fewer problematic emissions such as nitrogen oxides and particulate matter. In response, newer combustion methods, like homogeneous charge compression ignition and fuel cells, are being researched alongside the old standard of efficiency, the compression ignition or diesel engine. These newer technologies present a number of benefits but still have significant challenges to overcome. As a result, renewed interest has risen in making diesel engines cleaner. The key to cleaning up the diesel engine is the placement of aftertreatment devices in the exhaust. These devices have shown great potential in reducing emission levels below regulatory levels while still allowing for increased fuel economy versus a gasoline engine. However, these devices are subject to many flow control issues. While experimental evaluation of these devices helps to understand these issues better, it is impossible to solve the problem through experimentation alone because of time and cost constraints. Because of this, accurate models are needed in conjunction with the experimental work. In this dissertation, the author examines the entire exhaust system including reacting gas dynamics and aftertreatment devices, and develops a complete numerical model for it. The author begins by analyzing the current one-dimensional gas-dynamics simulation models used for internal combustion engine simulations. It appears that more accurate and faster numerical method is available, in particular, those developed in aeronautical engineering, and the author successfully implements one for the exhaust system. The author then develops a comprehensive literature search to better understand the aftertreatment devices. A number of these devices require a secondary injection of fuel or reductant in the exhaust stream. Accordingly, the author develops a simple post-cylinder injection model which can be easily tuned to match experimental findings. In addition, the author creates a general catalyst model which can be used to model virtually all of the different aftertreatment devices. Extensive validation of this model with experimental data is presented along with all of the numerical algorithms needed to reproduce the model.

  16. Using Innovation Diffusion Theory and the Technolgy Acceptance Model to Evaluate the Security of Wireless Mobile Devices at a Post Secondary Institution

    ERIC Educational Resources Information Center

    Feliciano-Torres, Hector L.

    2017-01-01

    The purpose of this quantitative, descriptive non experimental study was to investigate the use of wireless mobile network devices at a post-secondary institution using the innovation diffusion theory (IDT) and technology acceptance model (TAM) as background theories. The researcher intended to explore how students and personnel of the institution…

  17. Simulation of Electric Potentials and Ion Motion in Planar Electrode Structures for Lossless Ion Manipulations (SLIM)

    DOE PAGES

    Garimella, Sandilya V. B; Ibrahim, Yehia M.; Webb, Ian K.; ...

    2014-09-26

    Here we report a conceptual study and computational evaluation of novel planar electrode Structures for Lossless Ion Manipulations (SLIM). Planar electrode SLIM devices were designed that allow for flexible ion confinement, transport and storage using a combination of RF and DC fields. Effective potentials can be generated that provide near ideal regions for confining ions in the presence of a gas. Ion trajectory simulations using SIMION 8.1 demonstrated the capability for lossless ion motion in these devices over a wide m/z range and a range of electric fields at low pressures (e.g. a few torr). More complex ion manipulations, e.g.more » turning ions by 90° and dynamically switching selected ion species into orthogonal channels, are also feasible. Lastly, the performance of SLIM devices at ~4 torr pressure for performing ion mobility based separations (IMS) is computationally evaluated and compared to initial experimental results, and both of which agree closely with experimental and theoretical IMS performance for a conventional drift tube design.« less

  18. Determination of excitation profile and dielectric function spatial nonuniformity in porous silicon by using WKB approach.

    PubMed

    He, Wei; Yurkevich, Igor V; Canham, Leigh T; Loni, Armando; Kaplan, Andrey

    2014-11-03

    We develop an analytical model based on the WKB approach to evaluate the experimental results of the femtosecond pump-probe measurements of the transmittance and reflectance obtained on thin membranes of porous silicon. The model allows us to retrieve a pump-induced nonuniform complex dielectric function change along the membrane depth. We show that the model fitting to the experimental data requires a minimal number of fitting parameters while still complying with the restriction imposed by the Kramers-Kronig relation. The developed model has a broad range of applications for experimental data analysis and practical implementation in the design of devices involving a spatially nonuniform dielectric function, such as in biosensing, wave-guiding, solar energy harvesting, photonics and electro-optical devices.

  19. E-Pad: a comfortable electrocutaneous-based tactile feedback display

    NASA Astrophysics Data System (ADS)

    Wang, Jiabin; Zhao, Lu; Liu, Yue; Wang, Yongtian; Cai, Yi

    2018-01-01

    The devices with touchscreen are becoming more popular recently; however, most of them suffer from the crucial drawbacks of lacking accurate tactile feedback. A novel electrocutaneous-based tactile device with the name of E-pad is proposed to provide a dynamic and static low-voltage feedback for touchscreen. We optimize the key parameters of the output voltage and design custom-made hardwares to guarantee a comfortable user experience. Users could move their fingers freely across the touchscreen of the proposed device to really feel virtual objects. Two preliminary experiments are conducted to evaluate the interactive performance of the proposed device and the experimental results show that the proposed device can provide a comfortable and distinct tactile feedback.

  20. A handheld optical device for skin profile measurement

    NASA Astrophysics Data System (ADS)

    Sun, Jiuai; Liu, Xiaojin

    2018-04-01

    This paper describes a portable optical scanning device designed for skin surface measurement on both colour and 3D geometry through a relative easy and cost effective multiple light source photometric stereo method. The validation of colour recovered had been verified through its application on skin lesion segmentation in our early work. This paper focuses on the reconstructed topographic data which are subject to further evaluation and advancement. The evaluation work takes the skin in vitro as an application scenario and compares the experimental result to that obtained by using a commercial product. The experiments show that this handheld device can measure the skin profile significantly closer to that of the ground truth and have the additional function of skin colour recovery.

  1. Experimental evaluation of the optical quality of DMD SLM for its application as Fourier holograms displaying device

    NASA Astrophysics Data System (ADS)

    Molodtsov, D. Y.; Cheremkhin, P. A.; Krasnov, V. V.; Rodin, V. G.

    2016-04-01

    In this paper, the optical quality of micromirror DMD spatial light modulator (SLM) is evaluated and its applicability as an output device for holographic filters in dispersive correlators is analyzed. The possibility of using of DMD SLM extracted from consumer DLP-projector was experimentally evaluated by displaying of Fourier holograms. Software for displaying of holograms was developed. Experiments on holograms reconstruction was conducted with a different number of holograms pixels (and different placement on SLM). Reduction of number of pixels of output hologram (i.e. size of minimum resolvable element) led to improvement of reconstructed image quality. The evaluation shows that not every DMD-chip has acceptable optical quality for its application as display device for Fourier holograms. It was determined that major factor of reconstructed image quality degradation is a curvature of surface of SLM or its safety glass. Ranging hologram size allowed to estimate approximate size of sufficiently flat area of SLM matrix. For tested SLM it was about 1.5 mm. Further hologram size increase led to significant reconstructed image quality degradation. Developed and applied a technique allows to quickly estimate maximum size of holograms that can be displayed with specific SLM without significant degradation of reconstructed image. Additionally it allows to identify areas on the SLM with increased curvature of the surface.

  2. Experimental characterization and analysis of the BITalino platforms against a reference device.

    PubMed

    Batista, Diana; Silva, Hugo; Fred, Ana

    2017-07-01

    Low-cost hardware platforms for biomedical engineering are becoming increasingly available, which empower the research community in the development of new projects in a wide range of areas related with physiological data acquisition. Building upon previous work by our group, this work compares the quality of the data acquired by means of two different versions of the multimodal physiological computing platform BITalino, with a device that can be considered a reference. We acquired data from 5 sensors, namely Accelerometry (ACC), Electrocardiography (ECG), Electroencephalography (EEG), Electrodermal Activity (EDA) and Electromyography (EMG). Experimental evaluation shows that ACC, ECG and EDA data are highly correlated with the reference in what concerns the raw waveforms. When compared by means of their commonly used features, EEG and EMG data are also quite similar across the different devices.

  3. [A Feasibility Study of closing the small bowel with high-frequency welding device].

    PubMed

    Zhou, Huabin; Han, Shuai; Chen, Jun; Huang, Dequn; Peng, Liang; Ning, Jingxuan; Li, Zhou

    2014-12-01

    This study aimed to evaluate the feasibility and effectiveness of closing the small bowel in an ex vivo porcine model with high-frequency welding device. A total of 100 porcine small bowels were divided into two groups, and then were closed with two different methods. The fifty small bowels in experimental group were closed by the high-frequency welding device, and the other fifty small bowels in comparison group were hand-sutured. All the small bowels were subjected to leak pressure testing later on. The speed of closure and bursting pressure were compared. The 50 porcine small bowels closed by the high-frequency welding device showed a success rate of 100%. Compared with the hand-sutured group, the bursting pressures of the former were significantly lower (P<0.01) and the closing process was significantly shorter (P<0.01). The pathological changes of the closed ends mainly presented as acute thermal and pressure induced injury. Experimental results show that the high-frequency welding device has higher feasibility in closing the small bowel.

  4. An Experimental Device for Generating High Frequency Perturbations in Supersonic Wind Tunnels

    NASA Technical Reports Server (NTRS)

    Melcher, Kevin J.; Ibrahim, Mounir B.

    1996-01-01

    This paper describes the analytical study of a device that has been proposed as a mechanism for generating gust-like perturbations in supersonic wind tunnels. The device is envisioned as a means to experimentally validate dynamic models and control systems designed for high-speed inlets. The proposed gust generator is composed of two flat trapezoidal plates that modify the properties of the flow ingested by the inlet. One plate may be oscillated to generate small perturbations in the flow. The other plate is held stationary to maintain a constant angle-of-attack. Using an idealized approach, design equations and performance maps for the new device were developed from the compressible flow relations. A two-dimensional CFD code was used to confirm the correctness of these results. The idealized approach was then used to design and evaluate a new gust generator for a 3.05-meter by 3.05-meter (10-foot by 10-foot) supersonic wind tunnel.

  5. Evaluation of the SeedCounter, A Mobile Application for Grain Phenotyping.

    PubMed

    Komyshev, Evgenii; Genaev, Mikhail; Afonnikov, Dmitry

    2016-01-01

    Grain morphometry in cereals is an important step in selecting new high-yielding plants. Manual assessment of parameters such as the number of grains per ear and grain size is laborious. One solution to this problem is image-based analysis that can be performed using a desktop PC. Furthermore, the effectiveness of analysis performed in the field can be improved through the use of mobile devices. In this paper, we propose a method for the automated evaluation of phenotypic parameters of grains using mobile devices running the Android operational system. The experimental results show that this approach is efficient and sufficiently accurate for the large-scale analysis of phenotypic characteristics in wheat grains. Evaluation of our application under six different lighting conditions and three mobile devices demonstrated that the lighting of the paper has significant influence on the accuracy of our method, unlike the smartphone type.

  6. Evaluation of a wireless activity monitoring system to quantify locomotor activity in horses in experimental settings.

    PubMed

    Fries, M; Montavon, S; Spadavecchia, C; Levionnois, O L

    2017-03-01

    Methods of evaluating locomotor activity can be useful in efforts to quantify behavioural activity in horses objectively. To evaluate whether an accelerometric device would be adequate to quantify locomotor activity and step frequency in horses, and to distinguish between different levels of activity and different gaits. Observational study in an experimental setting. Dual-mode (activity and step count) piezo-electric accelerometric devices were placed at each of 4 locations (head, withers, forelimb and hindlimb) in each of 6 horses performing different controlled activities including grazing, walking at different speeds, trotting and cantering. Both the activity count and step count were recorded and compared by the various activities. Statistical analyses included analysis of variance for repeated measures, receiver operating characteristic curves, Bland-Altman analysis and linear regression. The accelerometric device was able to quantify locomotor activity at each of the 4 locations investigated and to distinguish between gaits and speeds. The activity count recorded by the accelerometer placed on the hindlimb was the most accurate, displaying a clear discrimination between the different levels of activity and a linear correlation to speed. The accelerometer placed on the head was the only one to distinguish specifically grazing behaviour from standing. The accelerometer placed on the withers was unable to differentiate different gaits and activity levels. The step count function measured at the hindlimb was reliable but the count was doubled at the walk. The dual-mode accelerometric device was sufficiently accurate to quantify and compare locomotor activity in horses moving at different speeds and gaits. Positioning the device on the hindlimb allowed for the most accurate results. The step count function can be useful but must be manually corrected, especially at the walk. © 2016 EVJ Ltd.

  7. Seven Experiment Designs Addressing Problems of Safety and Capacity on Two-Lane Rural Highways : Volume 6. Experimental Design for Comparative Evaluation of Warning-Advisory and Regulatory Traffic Control Devices

    DOT National Transportation Integrated Search

    2006-04-14

    This report presents the results of the national evaluation of the South Lake Tahoe coordinated Transit System (CTS) Project. The CTS Project involved combining transit services offered by private and public sector stakeholders in South Lake Tahoe in...

  8. Evaluating the ergonomics of BCI devices for research and experimentation.

    PubMed

    Ekandem, Joshua I; Davis, Timothy A; Alvarez, Ignacio; James, Melva T; Gilbert, Juan E

    2012-01-01

    The use of brain computer interface (BCI) devices in research and applications has exploded in recent years. Applications such as lie detectors that use functional magnetic resonance imaging (fMRI) to video games controlled using electroencephalography (EEG) are currently in use. These developments, coupled with the emergence of inexpensive commercial BCI headsets, such as the Emotiv EPOC ( http://emotiv.com/index.php ) and the Neurosky MindWave, have also highlighted the need of performing basic ergonomics research since such devices have usability issues, such as comfort during prolonged use, and reduced performance for individuals with common physical attributes, such as long or coarse hair. This paper examines the feasibility of using consumer BCIs in scientific research. In particular, we compare user comfort, experiment preparation time, signal reliability and ease of use in light of individual differences among subjects for two commercially available hardware devices, the Emotiv EPOC and the Neurosky MindWave. Based on these results, we suggest some basic considerations for selecting a commercial BCI for research and experimentation. STATEMENT OF RELEVANCE: Despite increased usage, few studies have examined the usability of commercial BCI hardware. This study assesses usability and experimentation factors of two commercial BCI models, for the purpose of creating basic guidelines for increased usability. Finding that more sensors can be less comfortable and accurate than devices with fewer sensors.

  9. An Analytical and Experimental Analysis of Factors Affecting Exhaust System Performance in Sea Level Static Jet Engine Test Facilities.

    DTIC Science & Technology

    1972-12-01

    include filtering devices, venturi scrubbers , and electrostatic precipitators. These have been evaluated as unsatisfactory from considerations of...Early studies of pollution abatement systems have resulted in the selection and development of a nucleation scrubber [Ref. 47]. Other devices analyzed...the venturi system is its inability to operate efficiently over greater than a 10 percent interval away from its design point, which is an

  10. Basic investigation into the electrical performance of solid electrolyte membranes

    NASA Technical Reports Server (NTRS)

    Richter, R.

    1982-01-01

    The electrical performance of solid electrolyte membranes was investigated analytically and the results were compared with experimental data. It is concluded that in devices that are used for pumping oxygen the major power losses have to be attributed to the thin film electrodes. Relations were developed by which the effectiveness of tubular solid electrolyte membranes can be determined and the optimum length evaluated. The observed failure of solid electrolyte tube membranes in very localized areas is explained by the highly non-uniform current distribution in the membranes. The analysis points to a possible contact resistance between the electrodes and the solid electrolyte material. This possible contact resistance remains to be investigated experimentally. It is concluded that film electrodes are not appropriate for devices which operate with current flow, i.e., pumps though they can be employed without reservation in devices that measure oxygen pressures if a limited increase in the response time can be tolerated.

  11. Piezoelectric energy harvesting based on shear mode 0.71Pb(Mg(1/3)Nb(2/3))O3-0.29PbTiO3 single crystals.

    PubMed

    Ren, Bo; Or, Siu Wing; Wang, Feifei; Zhao, Xiangyong; Luo, Haosu; Li, Xiaobing; Zhang, Qinhui; Di, Wenning; Zhang, Yaoyao

    2010-06-01

    In this paper we theoretically and experimentally present a nonresonant vibration energy harvesting device based on the shear mode of 0.71Pb(Mg(1/3)Nb(2/3))O3-0.29PbTiO3 single crystals. The electrical properties of the energy harvesting device were evaluated using an analytical method. Good consistency was obtained between the analytical and experimental results. Under a mass load of 200 g, a peak voltage of 11.3 V and maximum power of 0.70 mW were obtained at 500 Hz when connecting a matching load resistance of 91 komega. A high output could always be obtained within a very wide frequency range. The results demonstrate the potential of the device in energy harvesting applied to low-power portable electronics and wireless sensors.

  12. Polymer taper bridge for silicon waveguide to single mode waveguide coupling

    NASA Astrophysics Data System (ADS)

    Kruse, Kevin; Middlebrook, Christopher T.

    2016-03-01

    Coupling of optical power from high-density silicon waveguides to silica optical fibers for signal routing can incur high losses and often requires complex end-face preparation/processing. Novel coupling device taper structures are proposed for low coupling loss between silicon photonic waveguides and single mode fibers are proposed and devices are fabricated and measured in terms of performance. Theoretical mode conversion models for waveguide tapers are derived for optimal device structure design and performance. Commercially viable vertical and multi-layer taper designs using polymer waveguide materials are proposed as innovative, cost-efficient, and mass-manufacturable optical coupling devices. The coupling efficiency for both designs is determined to evaluate optimal device dimensions and alignment tolerances with both silicon rib waveguides and silicon nanowire waveguides. Propagation loss as a function of waveguide roughness and metallic loss are determined and correlated to waveguide dimensions to obtain total insertion loss for the proposed taper designs. Multi-layer tapers on gold-sputtered substrates are fabricated through photolithography as proof-of-concept devices and evaluated for device loss optimization. Tapered waveguide coupling loss with Si WGs (2.74 dB) was experimentally measured with high correlation to theoretical results.

  13. Clinical Evaluation of a Novel Intrarectal Device for Management of Fecal Incontinence in Bedridden Patients.

    PubMed

    Singh, Sandeep; Bhargava, Balram; Vasantha, Padma; Bhatia, Rohit; Sharma, Hanish; Pal, Sujoy; Sahni, Peush; Makharia, Govind K

    The primary objective of the study was to evaluate the safety and efficacy of a stool management kit (SMK) for containment of fecal incontinence in hospitalized bedridden patients. A single-group quasi-experimental study. Twenty bedridden adults who had at least 1 episode of fecal incontinence in the prior 24 hours participated in the study. The study setting was the neurological unit of the All India Institute of Medical Sciences in New Delhi, India. The study was carried out in 2 phases. The device was placed in situ for up to 24 hours in 10 patients during phase I of the study and up to 120 hours in an additional 10 patients during phase II. Participants were assessed for anorectal injury and peripheral device leakage on a 4- to 6-hourly basis. Sigmoidoscopy was performed to evaluate for any mucosal trauma or alteration of anorectal pathology after retrieval of the device. The device was successfully placed in all patients following the first attempt to place the device; 80% of patients retained the device until planned removal. The SMK diverted fecal matter without anal leakage in 174 (93.5%) out of 186 assessment points in a group of 20 patients. The devices remained in situ for 21 ± 0.2 and 84.5 ± 38.9 hours during phase I and phase II, respectively. None experienced anorectal bleeding, sphincter injury, or mucosal ulceration with device usage. Post-device sigmoidoscopy revealed erythema at the site of diverter placement in 2 participants. Study findings suggest that the SMK successfully diverted liquid to semiformed fecal exudate without peripheral device leakage in 93.5% of bedridden patients. No serious adverse events occurred. Additional research is needed to compare its effectiveness with that of currently available intrarectal balloon devices.

  14. The Impact of User-Input Devices on Virtual Desktop Trainers

    DTIC Science & Technology

    2010-09-01

    playing the game more enjoyable. Some of these changes include the design of controllers, the controller interface, and ergonomic changes made to...within subjects experimental design to evaluate young active duty Soldier’s ability to move and shoot in a virtual environment using different input...sufficient gaming proficiency, resulting in more time dedicated to training military skills. We employed a within subjects experimental design to

  15. Critical Current Test of Liquid Hydrogen Cooled HTC Superconductors under External Magnetic Field

    NASA Astrophysics Data System (ADS)

    Shirai, Yasuyuki; Shiotsu, Masahiro; Tatsumoto, Hideki; Kobayashi, Hiroaki; Naruo, Yoshihiro; Nonaka, Satoshi; Inatani, Yoshifumi

    High-Tc (HTC) superconductors including MgB2 will show excellent properties under temperature of Liquid Hydrogen (LH2:20K), which has large latent heat and low viscosity coefficient. In order to design and fabricate the LH2 cooled superconducting energy devices, we must clear the cooling property of LH2 for superconductors, the cooling system and safety design of LH2 cooled superconducting devices and electro-magnetic property evaluation of superconductors (BSCCO, REBCO and MgB2) and their magnets cooled by LH2. As the first step of the study, an experimental setup which can be used for investigating heat transfer characteristics of LH2 in a pool and also in forced flow (circulation loop with a pump), and also for evaluation of electro-magnetic properties of LH2 cooled superconductors under external magnetic field (up to 7 T). In this paper, we will show a short sketch of the experimental set-up, practical experiences in safety operation of liquid hydrogen cooling system and example test results of critical current evaluation of HTC superconductors cooled by LH2.

  16. A Study to Determine the Effectiveness of Letter Evaluation as a Learning Device in Business Correspondence Courses.

    ERIC Educational Resources Information Center

    Baker, William Henry

    The purpose of this study was to determine whether a letter-evaluation method would be as effective as the traditional letter-writing method when applied in a college level business correspondence class. One hundred twenty-nine Brigham Young University students were divided into two experimental and two control groups, and categorized according to…

  17. Computational design and in vitro characterization of an integrated maglev pump-oxygenator.

    PubMed

    Zhang, Juntao; Taskin, M Ertan; Koert, Andrew; Zhang, Tao; Gellman, Barry; Dasse, Kurt A; Gilbert, Richard J; Griffith, Bartley P; Wu, Zhongjun J

    2009-10-01

    For the need for respiratory support for patients with acute or chronic lung diseases to be addressed, a novel integrated maglev pump-oxygenator (IMPO) is being developed as a respiratory assist device. IMPO was conceptualized to combine a magnetically levitated pump/rotor with uniquely configured hollow fiber membranes to create an assembly-free, ultracompact system. IMPO is a self-contained blood pump and oxygenator assembly to enable rapid deployment for patients requiring respiratory support or circulatory support. In this study, computational fluid dynamics (CFD) and computer-aided design were conducted to design and optimize the hemodynamics, gas transfer, and hemocompatibility performances of this novel device. In parallel, in vitro experiments including hydrodynamic, gas transfer, and hemolysis measurements were conducted to evaluate the performance of IMPO. Computational results from CFD analysis were compared with experimental data collected from in vitro evaluation of the IMPO. The CFD simulation demonstrated a well-behaved and streamlined flow field in the main components of this device. The results of hydrodynamic performance, oxygen transfer, and hemolysis predicted by computational simulation, along with the in vitro experimental data, indicate that this pump-lung device can provide the total respiratory need of an adult with lung failure, with a low hemolysis rate at the targeted operating condition. These detailed CFD designs and analyses can provide valuable guidance for further optimization of this IMPO for long-term use.

  18. Double-Barrier Memristive Devices for Unsupervised Learning and Pattern Recognition.

    PubMed

    Hansen, Mirko; Zahari, Finn; Ziegler, Martin; Kohlstedt, Hermann

    2017-01-01

    The use of interface-based resistive switching devices for neuromorphic computing is investigated. In a combined experimental and numerical study, the important device parameters and their impact on a neuromorphic pattern recognition system are studied. The memristive cells consist of a layer sequence Al/Al 2 O 3 /Nb x O y /Au and are fabricated on a 4-inch wafer. The key functional ingredients of the devices are a 1.3 nm thick Al 2 O 3 tunnel barrier and a 2.5 mm thick Nb x O y memristive layer. Voltage pulse measurements are used to study the electrical conditions for the emulation of synaptic functionality of single cells for later use in a recognition system. The results are evaluated and modeled in the framework of the plasticity model of Ziegler et al. Based on this model, which is matched to experimental data from 84 individual devices, the network performance with regard to yield, reliability, and variability is investigated numerically. As the network model, a computing scheme for pattern recognition and unsupervised learning based on the work of Querlioz et al. (2011), Sheridan et al. (2014), Zahari et al. (2015) is employed. This is a two-layer feedforward network with a crossbar array of memristive devices, leaky integrate-and-fire output neurons including a winner-takes-all strategy, and a stochastic coding scheme for the input pattern. As input pattern, the full data set of digits from the MNIST database is used. The numerical investigation indicates that the experimentally obtained yield, reliability, and variability of the memristive cells are suitable for such a network. Furthermore, evidence is presented that their strong I - V non-linearity might avoid the need for selector devices in crossbar array structures.

  19. Numerical evaluation of heating in the human head due to magnetic resonance imaging (MRI)

    NASA Astrophysics Data System (ADS)

    Nguyen, Uyen; Brown, Steve; Chang, Isaac; Krycia, Joe; Mirotznik, Mark S.

    2003-06-01

    In this paper we present a numerical model for evaluating tissue heating during magnetic resonance imaging (MRI). Our method, which included a detailed anatomical model of a human head, calculated both the electromagnetic power deposition and the associated temperature elevations during a MRI head examination. Numerical studies were conducted using a realistic birdcage coil excited at frequencies ranging from 63 MHz to 500 MHz. The model was validated both experimentally and analytically. The experimental validation was performed at the MR test facility located at the FDA's Center for Devices and Radiological Health (CDRH).

  20. Validation of an automated mite counter for Dermanyssus gallinae in experimental laying hen cages.

    PubMed

    Mul, Monique F; van Riel, Johan W; Meerburg, Bastiaan G; Dicke, Marcel; George, David R; Groot Koerkamp, Peter W G

    2015-08-01

    For integrated pest management (IPM) programs to be maximally effective, monitoring of the growth and decline of the pest populations is essential. Here, we present the validation results of a new automated monitoring device for the poultry red mite (Dermanyssus gallinae), a serious pest in laying hen facilities world-wide. This monitoring device (called an "automated mite counter") was validated in experimental laying hen cages with live birds and a growing population of D. gallinae. This validation study resulted in 17 data points of 'number of mites counted' by the automated mite counter and the 'number of mites present' in the experimental laying hen cages. The study demonstrated that the automated mite counter was able to track the D. gallinae population effectively. A wider evaluation showed that this automated mite counter can become a useful tool in IPM of D. gallinae in laying hen facilities.

  1. Magnus effect: An overview of its past and future practical applications, 1850-1985, volumes 1 and 2

    NASA Astrophysics Data System (ADS)

    Borg, J.

    The report is in two volumes and is intended to present the known data and past and future applications of Magnus effect devices. (Magnus effect devices are very high lift devices which can be used in applications where airfoils are currently used.) This first volume includes the history of Magnus effect devices, theory and principles, a significant patent review, practical marine applications, formulas and experimental data, comparisons of Magnus effect and other state-of-the-art devices, identification of further testing needed, and a proposed test program. Appendices include rudder research and a literature critique. The second volume is a collection of the drawings for 39 magnus effect patents plus a critique of each patent evaluating its potential, especially for marine applications.

  2. In search of the autologous clip: a case for experimental standardization.

    PubMed

    Krugman, Kimberly A; Martin, Kimberly E; Cosgriff, Ned; Slakey, Douglas P

    2011-10-01

    In an effort to enable faster and, at times, more challenging surgeries without compromising patient or physician safety, medical device manufacturers have created myriad solutions to vascular ligation through the development of novel tools. The speed of development, FDA approval, and dissemination of these devices into the hands of surgeons often outpaces the ability of investigators to critically evaluate comparative effectiveness of these devices. The Medline database was searched for energy-based vessel ligation devices. To remove any perception bias against non-Covidien instruments, critical review was applied only to the devices manufactured by our company. We report on the variability present in published results and offer vital metrics for future studies. Standardized testing and reporting for measures of safety and efficacy of these surgical instruments awaits definition from a consensus group.

  3. Procedure de caracterisation thermophysique d'un materiau a changement de phase composite pour le stockage thermique

    NASA Astrophysics Data System (ADS)

    Le Du, Mathieu

    The use of phase change materials (PCMs) allows to store and release large amounts of energy in reduced volumes by using latent heat storage through melting and solidifying at specific temperatures. Phase change materials received a great interest for reducing energy consumption by easing the implementation of passive solar heating and cooling. They can be integrated to buildings as wallboards to improve the heat storage capacity. In this study, an original experimental device has allowed to characterize the thermophysical proprieties of a composite wallboard constituted of PCMs. Generally, PCMs are characterized by calorimetric methods which use very small quantities of material. The device used can characterize large sample's dimensions, as they could be used in real condition. Apparent thermal conductivity and specific heat have been measured for various temperatures. During phase change process, total and latent heat storage capacities have been evaluated with the peak melting and freezing temperatures. Results are compared to the manufacturer's data and data from literature. Incoherencies have been found between sources. Despite several differences with published data, overall results are similar to the latest information, which allow validate the original experimental device. Thermal disturbances due to hysteresis have been noticed and discussed. Results allow suggesting recommendations on thermal procedure and experimental device to characterize efficiently this kind of materials. Temperature's ranges and heating and freezing rates affect results and it must be considered in the characterization. Moreover, experimental devices have to be designed to allow similar heating and freezing rates in order to compare results during melting and freezing. Key words: Phase change material, latent thermal storage, thermophysical characterization.

  4. Evaluating the interaction of a tracheobronchial stent in an ovine in-vivo model.

    PubMed

    McGrath, Donnacha J; Thiebes, Anja Lena; Cornelissen, Christian G; O'Brien, Barry; Jockenhoevel, Stefan; Bruzzi, Mark; McHugh, Peter E

    2018-04-01

    Tracheobronchial stents are used to restore patency to stenosed airways. However, these devices are associated with many complications such as stent migration, granulation tissue formation, mucous plugging and stent strut fracture. Of these, granulation tissue formation is the complication that most frequently requires costly secondary interventions. In this study a biomechanical lung modelling framework recently developed by the authors to capture the lung in-vivo stress state under physiological loading is employed in conjunction with ovine pre-clinical stenting results and device experimental data to evaluate the effect of stent interaction on granulation tissue formation. Stenting is simulated using a validated model of a prototype covered laser-cut tracheobronchial stent in a semi-specific biomechanical lung model, and physiological loading is performed. Two computational methods are then used to predict possible granulation tissue formation: the standard method which utilises the increase in maximum principal stress change, and a newly proposed method which compares the change in contact pressure over a respiratory cycle. These computational predictions of granulation tissue formation are then compared to pre-clinical stenting observations after a 6-week implantation period. Experimental results of the pre-clinical stent implantation showed signs of granulation tissue formation both proximally and distally, with a greater proximal reaction. The standard method failed to show a correlation with the experimental results. However, the contact change method showed an apparent correlation with granulation tissue formation. These results suggest that this new method could be used as a tool to improve future device designs.

  5. Preparation of Partial-Thickness Burn Wounds in Rodents Using a New Experimental Burning Device.

    PubMed

    Sakamoto, Michiharu; Morimoto, Naoki; Ogino, Shuichi; Jinno, Chizuru; Kawaguchi, Atsushi; Kawai, Katsuya; Suzuki, Shigehiko

    2016-06-01

    The manual application of hot water or hot metal to an animal's skin surface is often used to prepare burn wound models. However, manual burn creation is subject to human variability. We developed a new device that can control the temperature, time, and pressure of contact to produce precise and reproducible animal burn wounds and investigated the conditions required to prepare various burn wounds using our new device. We prepared burn wounds on F344 rats using 3 contact times 2, 4, and 10 seconds using a stamp heated to 80°C. We observed the wound-healing process macroscopically and histologically and evaluated the burn depth using a laser speckle contrast-imaging device, which evaluated the blood flow of the wound. The changes in the burned area over time, tissue perfusion of the burn wounds, histological evaluation of the burn depth by hematoxylin-eosin and azocarmine and aniline blue staining, and the epithelialization rate (the ratio of the epithelialized area to the wound length) were evaluated on histological sections. Results indicated that the burn wounds prepared with contact times of 2, 4, and 10 seconds corresponded to superficial dermal burns, deep dermal burns, and full-thickness burns, respectively. We demonstrated that partial- and full-thickness burn wounds can be precisely and reproducibly created with our new automated burning device.

  6. Passive Microfluidic device for Sub Millisecond Mixing

    PubMed Central

    McMahon, Jay; Mohamed, Hisham; Barnard, David; Shaikh, Tanvir R.; Mannella, Carmen A.; Wagenknecht, Terence; Lu, Toh-Ming

    2009-01-01

    We report the investigation of a novel microfluidic mixing device to achieve submillisecond mixing. The micromixer combines two fluid streams of several microliters per second into a mixing compartment integrated with two T- type premixers and 4 butterfly-shaped in-channel mixing elements. We have employed three dimensional fluidic simulations to evaluate the mixing efficiency, and have constructed physical devices utilizing conventional microfabrication techniques. The simulation indicated thorough mixing at flow rate as low as 6 µL/s. The corresponding mean residence time is 0.44 ms for 90% of the particles simulated, or 0.49 ms for 95% of the particles simulated, respectively. The mixing efficiency of the physical device was also evaluated using fluorescein dye solutions and FluoSphere-red nanoparticles suspensions. The constructed micromixers achieved thorough mixing at the same flow rate of 6 µL/s, with the mixing indices of 96% ± 1%, and 98% ± 1% for the dye and the nanoparticle, respectively. The experimental results are consistent with the simulation data. The device demonstrated promising capabilities for time resolved studies for macromolecular dynamics of biological macromolecules. PMID:20161619

  7. Randomized in vitro and in vivo evaluation of different biopsy needles and devices for breast biopsy.

    PubMed

    Helbich, T H; Rudas, M; Böhm, G; Huber, S; Wagner, T; Taucher, S; Wolf, G; Mostbeck, G H

    1999-01-01

    In an experimental study (in vitro and in vivo) we evaluated the efficacy of various biopsy needles/devices for breast biopsy. In vitro, biopsies of five human cadaveric breast specimens were performed using 33 different needles/devices ranging from 14 to 20-gauge. Of these 33 needles/devices, 22 optimally performing needles were selected for the in vivo study. In the clinical part of the study, 44 breast lesions were randomly biopsied with each of the 22 needles/devices under stereotactic guidance. Tissue specimens were analysed quantitatively and qualitatively. Several automatic long-throw guns (Acecut, Asap, Biopty, Magnum) obtained greater tissue areas and had a better histopathologic score than the conventional type of a side-notch needle like Trucut, an aspiration needle like Surecut, or an end-cut needle like Autovac. The automatic long-throw guns performed better than the short-throw Monopty gun. Regardless of needle size (14-20-gauge), breast biopsies should be routinely performed with automated long-throw side-notch guns (Acecut, Asap, Biopty, Magnum).

  8. I/O performance evaluation of a Linux-based network-attached storage device

    NASA Astrophysics Data System (ADS)

    Sun, Zhaoyan; Dong, Yonggui; Wu, Jinglian; Jia, Huibo; Feng, Guanping

    2002-09-01

    In a Local Area Network (LAN), clients are permitted to access the files on high-density optical disks via a network server. But the quality of read service offered by the conventional server is not satisfied because of the multiple functions on the server and the overmuch caller. This paper develops a Linux-based Network-Attached Storage (NAS) server. The Operation System (OS), composed of an optimized kernel and a miniaturized file system, is stored in a flash memory. After initialization, the NAS device is connected into the LAN. The administrator and users could configure the access the server through the web page respectively. In order to enhance the quality of access, the management of buffer cache in file system is optimized. Some benchmark programs are peformed to evaluate the I/O performance of the NAS device. Since data recorded in optical disks are usually for reading accesses, our attention is focused on the reading throughput of the device. The experimental results indicate that the I/O performance of our NAS device is excellent.

  9. Hand controller study of force and control mode

    NASA Technical Reports Server (NTRS)

    Morris, A. Terry

    1992-01-01

    The objectives are to compare and evaluate the utility and effectiveness of various input control devices, e.g., hand controllers, with respect to the relative importance of force and operation control mode (rate or position) for Space Station Freedom (SSF) related tasks. The topics are presented in viewgraph form and include the: Intelligent Research Systems Lab (ISRL) experimental design; Telerobotic Systems Research Laboratory (TSRL) final experimental design; and factor analysis summary of results.

  10. Feasibility of the runt cow for in vivo testing of a spinal interbody prosthesis with preliminary results.

    PubMed

    Buttermann, Glenn R; Mendenhall, H Vincent

    2012-04-01

    The optimal lumbar spinal disc prosthesis has yet to be developed. Failures of clinical device studies may be minimized by appropriate large animal preclinical studies. The lumbar spine of the mature "runt" cow, Corrientes breed, has been shown to have a number of desirable characteristics to the human. This study assessed the feasibility of the "runt" cow for in vivo testing of human-sized lumbar interbody implants and the ability to perform common analyses of explants. Eight cows (four experimental and four controls) were compared. The experimental animals had transosseous implantation of the disc prosthesis at L4-L5, and their spines were harvested at four or six months. They were evaluated for the ease of surgical access and healing, motion segment mobility, ability to remove the implant nondestructively, and microradiography and histomorphology. All animals had successful implantation. All explantations were performed without alteration to the devices. All animals had surgical healing and intended device motion, and histology found device stability by demonstrating bone ingrowth into the device's porous plates. There was a significant 46% increase in the amount of trabecular bone adjacent to the implants. The mature runt cow allows for implantation of human-sized interbody and intrabody spinal prostheses. This animal model allowed for macro- and histological analysis of the implant and surrounding tissues. In vivo stability was demonstrated for the disc prosthesis while also allowing for evaluation of intended mobility. Additionally, this is the first study to suggest increased bone density supporting an interbody prosthesis.

  11. Experimental and numerical investigation into the influence of loading conditions in biomechanical testing of locking plate fracture fixation devices

    PubMed Central

    MacLeod, A.; Simpson, A. H. R. W.

    2018-01-01

    Objectives Secondary fracture healing is strongly influenced by the stiffness of the bone-fixator system. Biomechanical tests are extensively used to investigate stiffness and strength of fixation devices. The stiffness values reported in the literature for locked plating, however, vary by three orders of magnitude. The aim of this study was to examine the influence that the method of restraint and load application has on the stiffness produced, the strain distribution within the bone, and the stresses in the implant for locking plate constructs. Methods Synthetic composite bones were used to evaluate experimentally the influence of four different methods of loading and restraining specimens, all used in recent previous studies. Two plate types and three screw arrangements were also evaluated for each loading scenario. Computational models were also developed and validated using the experimental tests. Results The method of loading was found to affect the gap stiffness strongly (by up to six times) but also the magnitude of the plate stress and the location and magnitude of strains at the bone-screw interface. Conclusions This study demonstrates that the method of loading is responsible for much of the difference in reported stiffness values in the literature. It also shows that previous contradictory findings, such as the influence of working length and very large differences in failure loads, can be readily explained by the choice of loading condition. Cite this article: A. MacLeod, A. H. R. W. Simpson, P. Pankaj. Experimental and numerical investigation into the influence of loading conditions in biomechanical testing of locking plate fracture fixation devices. Bone Joint Res 2018;7:111–120. DOI: 10.1302/2046-3758.71.BJR-2017-0074.R2. PMID:29363522

  12. A Middleware Based Approach to Dynamically Deploy Location Based Services onto Heterogeneous Mobile Devices Using Bluetooth in Indoor Environment

    NASA Astrophysics Data System (ADS)

    Sadhukhan, Pampa; Sen, Rijurekha; Das, Pradip K.

    Several methods for providing location based service (LBS) to mobile devices in indoor environment using wireless technologies like WLAN, RFID and Bluetooth have been proposed, implemented and evaluated. However, most of them do not focus on heterogeneity of mobile platforms, memory constraint of mobile devices, the adaptability of client or device to the new services it discovers whenever it reaches a new location. In this paper, we have proposed a Middleware based approach of LBS provision in the indoor environment, where a Bluetooth enabled Base Station (BS) detects Bluetooth enabled mobile devices and pushes a proper client application only to those devices that belong to some registered subscriber of LBS. This dynamic deployment enables the mobile clients to access any new service without having preinstalled interface to that service beforehand and thus the client's memory consumption is reduced. Our proposed work also addresses the other issues like authenticating the clients before providing them LBSs and introducing paid services. We have evaluated its performance in term of file transfer time with respect to file size and throughput with respect to distance. Experimental results on service consumption time by the mobile client for different services are also presented.

  13. Long-term stable active mount for reflective optics

    NASA Astrophysics Data System (ADS)

    Reinlein, C.; Brady, A.; Damm, C.; Mohaupt, M.; Kamm, A.; Lange, N.; Goy, M.

    2016-07-01

    We report on the development of an active mount with an orthogonal actuator matrix offering a stable shape optimization for gratings or mirrors. We introduce the actuator distribution and calculate the accessible Zernike polynomials from their actuator influence function. Experimental tests show the capability of the device to compensate for aberrations of grating substrates as we report measurements of a 110x105 mm2 and 220x210 mm2 device With these devices, we evaluate the position depending aberrations, long-term stability shape results, and temperature-induced shape variations. Therewith we will discuss potential applications in space telescopes and Earth-based facilities where long-term stability is mandatory.

  14. Probing dynamic behavior of electric fields and band diagrams in complex semiconductor heterostructures

    NASA Astrophysics Data System (ADS)

    Turkulets, Yury; Shalish, Ilan

    2018-01-01

    Modern bandgap engineered electronic devices are typically made of multi-semiconductor multi-layer heterostructures that pose a major challenge to silicon-era characterization methods. As a result, contemporary bandgap engineering relies mostly on simulated band structures that are hardly ever verified experimentally. Here, we present a method that experimentally evaluates bandgap, band offsets, and electric fields, in complex multi-semiconductor layered structures, and it does so simultaneously in all the layers. The method uses a modest optical photocurrent spectroscopy setup at ambient conditions. The results are analyzed using a simple model for electro-absorption. As an example, we apply the method to a typical GaN high electron mobility transistor structure. Measurements under various external electric fields allow us to experimentally construct band diagrams, not only at equilibrium but also under any other working conditions of the device. The electric fields are then used to obtain the charge carrier density and mobility in the quantum well as a function of the gate voltage over the entire range of operating conditions of the device. The principles exemplified here may serve as guidelines for the development of methods for simultaneous characterization of all the layers in complex, multi-semiconductor structures.

  15. Baseline experimental investigation of an electrohydrodynamically assisted heat pipe

    NASA Technical Reports Server (NTRS)

    Duncan, A. B.

    1995-01-01

    The increases in power demand and associated thermal management requirements of future space programs such as potential Lunar/Mars missions will require enhancing the operating efficiencies of thermal management devices. Currently, the use of electrohydrodynamically (EHD) assisted thermal control devices is under consideration as a potential method of increasing thermal management system capacity. The objectives of the currently described investigation included completing build-up of the EHD-Assisted Heat Pipe Test bed, developing test procedures for an experimental evaluation of the unassisted heat pipe, developing an analytical model capable of predicting the performance limits of the unassisted heat pipe, and obtaining experimental data which would define the performance characteristics of the unassisted heat pipe. The information obtained in the currently proposed study will be used in order to provide extensive comparisons with the EHD-assisted performance observations to be obtained during the continuing investigation of EHD-Assisted heat transfer devices. Through comparisons of the baseline test bed data and the EHD assisted test bed data, accurate insight into the performance enhancing characteristics of EHD augmentation may be obtained. This may lead to optimization, development, and implementation of EHD technology for future space programs.

  16. Grating-patterned FeCo coated surface acoustic wave device for sensing magnetic field

    NASA Astrophysics Data System (ADS)

    Wang, Wen; Jia, Yana; Xue, Xufeng; Liang, Yong; Du, Zhaofu

    2018-01-01

    This study addresses the theoretical and experimental investigations of grating-patterned magnetostrictive FeCo coated surface acoustic wave (SAW) device for sensing magnetic field. The proposed sensor is composed of a configuration of differential dual-delay-line oscillators, and a magnetostrictive FeCo grating array deposited along the SAW propagation path of the sensing device, which suppresses effectively the hysteresis effect by releasing the internal binding force in FeCo. The magnetostrictive strain and ΔE effect from the FeCo coating modulates the SAW propagation characteristic, and the corresponding shift in differential oscillation frequency was utilized to evaluate the measurant. A theoretical model is performed to investigate the wave propagation in layered structure of FeCo/LiNbO3 in the effect of magnetostrictive, and allowing determining the optimal structure. The experimental results indicate that higher sensitivity, excellent linearity, and lower hysteresis error over the typical FeCo thin-film coated sensor were achieved from the grating-patterned FeCo coated sensor successfully.

  17. Scientific Ground of a New Optical Device for Contactless Measurement of the Small Spatial Displacements of Control Object Surfaces

    NASA Astrophysics Data System (ADS)

    Miroshnichenko, I. P.; Parinov, I. A.

    2017-06-01

    It is proposed the computational-experimental ground of newly developed optical device for contactless measurement of small spatial displacements of control object surfaces based on the use of new methods of laser interferometry. The proposed device allows one to register linear and angular components of the small displacements of control object surfaces during the diagnosis of the condition of structural materials for forced elements of goods under exploring by using acoustic non-destructive testing methods. The described results are the most suitable for application in the process of high-precision measurements of small linear and angular displacements of control object surfaces during experimental research, the evaluation and diagnosis of the state of construction materials for forced elements of goods, the study of fast wave propagation in layered constructions of complex shape, manufactured of anisotropic composite materials, the study of damage processes in modern construction materials in mechanical engineering, shipbuilding, aviation, instrumentation, power engineering, etc.

  18. Interconnection network architectures based on integrated orbital angular momentum emitters

    NASA Astrophysics Data System (ADS)

    Scaffardi, Mirco; Zhang, Ning; Malik, Muhammad Nouman; Lazzeri, Emma; Klitis, Charalambos; Lavery, Martin; Sorel, Marc; Bogoni, Antonella

    2018-02-01

    Novel architectures for two-layer interconnection networks based on concentric OAM emitters are presented. A scalability analysis is done in terms of devices characteristics, power budget and optical signal to noise ratio by exploiting experimentally measured parameters. The analysis shows that by exploiting optical amplifications, the proposed interconnection networks can support a number of ports higher than 100. The OAM crosstalk induced-penalty, evaluated through an experimental characterization, do not significantly affect the interconnection network performance.

  19. Towards standardized assessment of endoscope optical performance: geometric distortion

    NASA Astrophysics Data System (ADS)

    Wang, Quanzeng; Desai, Viraj N.; Ngo, Ying Z.; Cheng, Wei-Chung; Pfefer, Joshua

    2013-12-01

    Technological advances in endoscopes, such as capsule, ultrathin and disposable devices, promise significant improvements in safety, clinical effectiveness and patient acceptance. Unfortunately, the industry lacks test methods for preclinical evaluation of key optical performance characteristics (OPCs) of endoscopic devices that are quantitative, objective and well-validated. As a result, it is difficult for researchers and developers to compare image quality and evaluate equivalence to, or improvement upon, prior technologies. While endoscope OPCs include resolution, field of view, and depth of field, among others, our focus in this paper is geometric image distortion. We reviewed specific test methods for distortion and then developed an objective, quantitative test method based on well-defined experimental and data processing steps to evaluate radial distortion in the full field of view of an endoscopic imaging system. Our measurements and analyses showed that a second-degree polynomial equation could well describe the radial distortion curve of a traditional endoscope. The distortion evaluation method was effective for correcting the image and can be used to explain other widely accepted evaluation methods such as picture height distortion. Development of consensus standards based on promising test methods for image quality assessment, such as the method studied here, will facilitate clinical implementation of innovative endoscopic devices.

  20. Development of microarray device for functional evaluation of PC12D cell axonal extension ability

    NASA Astrophysics Data System (ADS)

    Nakamachi, Eiji; Yanagimoto, Junpei; Murakami, Shinya; Morita, Yusuke

    2014-04-01

    In this study, we developed a microarray bio-MEMS device that could trap PC12D (rat pheochromocytoma cells) cells to examine the intercellular interaction effect on the cell activation and the axonal extension ability. This is needed to assign particular patterns of PC12D cells to establish a cell functional evaluation technique. This experimental observation-based technique can be used for design of the cell sheet and scaffold for peripheral and central nerve regeneration. We have fabricated a micropillar-array bio-MEMS device, whose diameter was approximately 10 μm, by using thick photoresist SU-8 on the glass slide substrate. A maximum trapped PC12D cell ratio, 48.5%, was achieved. Through experimental observation of patterned PC12D "bi-cells" activation, we obtained the following results. Most of the PC12D "bi-cells" which had distances between 40 and 100 μm were connected after 24 h with a high probability. On the other hand, "bi-cells" which had distances between 110 and 200 μm were not connected. In addition, we measured axonal extension velocities in cases where the intercellular distance was between 40 and 100 μm. A maximum axonal extension velocity, 86.4 μm/h, was obtained at the intercellular distance of 40 μm.

  1. Application and use of spinal immobilization devices in zero-gravity flight

    NASA Technical Reports Server (NTRS)

    Krupa, Debra T.; Gosbee, John; Billica, Roger; Boyce, Joey B.

    1991-01-01

    A KC-135 parabolic flight was performed for the purpose of evaluation of spinal immobilization techniques in microgravity. The flight followed the standard 40 parabola profile with four NASA/KRUG experimenters involved. One performed as coordinator/recorder, one as test subject, and two as the Crew Medical Officers (CMO). The flight was to evaluate the application of spinal immobilization devices and techniques in microgravity as are performed during initial stabilization or patient transport scenarios. The sequence of detail for examination of the following objectives included: attempted cervical spine immobilization with all free floating, the patient restrained to the floor, various hand positioning techniques; c-collar placement; Kendrick Extrication Device (KED) application with various restraints for patient and CMO; patient immobilization and transport using the KED; patient transported on KED and spine board. Observations for each task are included. Major conclusions and issues are also included.

  2. Improved multiple-shot gun for use as a combustion stability rating device

    NASA Technical Reports Server (NTRS)

    Sokolowski, D. E.

    1973-01-01

    A program was conducted to develop and experimentally evaluate an improved version of a modified machine gun for use as a device for rating the relative combustion stability of various rocket combustors. Following the results of a previous study involving a caliber .30 machine gun, a caliber .50 machine gun was modified in order to extend the charge-size range of the device. Nitrocellulose charge sizes ranging from 1.004 to 9.720 grams were fired at rates up to four shots per second. Shock pressures up to 25,512 kN/sq m were measured near the end of a shortened gun barrel. A minimal resistance type of check valve permitted the gun to fire into pressurized regions; back pressures up to 3448 kN/sq m abs were tested. The final modified assembly was evaluated during combustion stability tests on rocket combustors burning a FLOX-methane propellant combination.

  3. Establishment of a new pull-out strength testing method to quantify early osseointegration-An experimental pilot study.

    PubMed

    Nonhoff, J; Moest, T; Schmitt, Christian Martin; Weisel, T; Bauer, S; Schlegel, K A

    2015-12-01

    The animal study aims to evaluate a new experimental model for measuring sole the influence of the surface characteristics independent from implant macro-design on the level of osseointegration by registering the pull-out strength needed for removal of experimental devices with different surfaces from artificial defects. Seventy-two test bodies (36 with the FRIADENT(®) plus surface, 36 with the P15/HAp biofunctionalized surface) were inserted in six adult domestic pigs with artificial calvarial defects. The experimental devices were designed to fit in the defects leaving a gap between the test body and the local bone. After 21 days of healing, the animals were sacrificed and the test bodies were pulled out with a standardised reproducible pull-out device measuring the pull-out strength. The pull-out strength for both groups was compared. Twenty-one days after insertion a mean force of 412 ± 142 N for the P15/HAp group and 183 ± 105 N for the FRIADENT(®) plus group was measured for the removal of the specimens from the calvarial bone. The difference between the groups was statistically significant (p < 0.0001). The experimental set-up seems to be a suitable method when measuring the impact of implant surfaces on the early stage of osseointegration. Copyright © 2015 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  4. Experimental Evaluation of a Device Prototype Based on Shape Memory Alloys for the Retrofit of Historical Buildings

    NASA Astrophysics Data System (ADS)

    Cardone, Donatello; Sofia, Salvatore

    2012-12-01

    Metallic tie-rods are currently used in many historical buildings for absorbing the out-of-plane horizontal forces of arches, vaults and roof trusses, despite they exhibit several limitations under service and seismic conditions. In this paper, a post-tensioned system based on the superelastic properties of Ni-Ti shape memory alloys is proposed for improving the structural performances of traditional metallic tie-rods. First, the thermal behavior under service conditions is investigated based on the results of numerical and experimental studies. Subsequently, the seismic performances under strong earthquakes are verified trough a number of shaking table tests on a 1:4-scale timber roof truss model. The outcomes of these studies fully confirm the achievement of the design objectives of the proposed prototype device.

  5. EXTRACTION AND DETECTION OF ARSENICALS IN SEAWEED VIA ACCELERATED SOLVENT EXTRACTION WITH ION CHROMATOGRAPHIC SEPARATION AND ICP-MS DETECTION

    EPA Science Inventory

    An accelerated solvent extraction (ASE) device was evaluated as a semi-automated means of extracting arsenicals from ribbon kelp. Objective was to investigate effect of experimentally controllable ASE parameters (pressure, temperature, static time and solvent composition) on extr...

  6. State-of-the-art robotic devices for ankle rehabilitation: Mechanism and control review.

    PubMed

    Hussain, Shahid; Jamwal, Prashant K; Ghayesh, Mergen H

    2017-12-01

    There is an increasing research interest in exploring use of robotic devices for the physical therapy of patients suffering from stroke and spinal cord injuries. Rehabilitation of patients suffering from ankle joint dysfunctions such as drop foot is vital and therefore has called for the development of newer robotic devices. Several robotic orthoses and parallel ankle robots have been developed during the last two decades to augment the conventional ankle physical therapy of patients. A comprehensive review of these robotic ankle rehabilitation devices is presented in this article. Recent developments in the mechanism design, actuation and control are discussed. The study encompasses robotic devices for treadmill and over-ground training as well as platform-based parallel ankle robots. Control strategies for these robotic devices are deliberated in detail with an emphasis on the assist-as-needed training strategies. Experimental evaluations of the mechanism designs and various control strategies of these robotic ankle rehabilitation devices are also presented.

  7. Experimental Determination of Demand Response Control Models and Cost of Control for Ensembles of Window-Mount Air Conditioners

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Geller, Drew Adam; Backhaus, Scott N.

    Control of consumer electrical devices for providing electrical grid services is expanding in both the scope and the diversity of loads that are engaged in control, but there are few experimentally-based models of these devices suitable for control designs and for assessing the cost of control. A laboratory-scale test system is developed to experimentally evaluate the use of a simple window-mount air conditioner for electrical grid regulation services. The experimental test bed is a single, isolated air conditioner embedded in a test system that both emulates the thermodynamics of an air conditioned room and also isolates the air conditioner frommore » the real-world external environmental and human variables that perturb the careful measurements required to capture a model that fully characterizes both the control response functions and the cost of control. The control response functions and cost of control are measured using harmonic perturbation of the temperature set point and a test protocol that further isolates the air conditioner from low frequency environmental variability.« less

  8. An innovative in vitro device providing continuous low doses of γ-rays mimicking exposure to the space environment: A dosimetric study

    NASA Astrophysics Data System (ADS)

    Pereda-Loth, V.; Franceries, X.; Afonso, A. S.; Ayala, A.; Eche, B.; Ginibrière, D.; Gauquelin-Koch, G.; Bardiès, M.; Lacoste-Collin, L.; Courtade-Saïdi, M.

    2018-02-01

    Astronauts are exposed to microgravity and chronic irradiation but experimental conditions combining these two factors are difficult to reproduce on earth. We have created an experimental device able to combine chronic irradiation and altered gravity that may be used for cell cultures or plant models in a ground based facility. Irradiation was provided by thorium nitrate powder, conditioned so as to constitute a sealed source that could be placed in an incubator. Cell plates or plant seedlings could be placed in direct contact with the source or at various distances above it. Moreover, a random positioning machine (RPM) could be positioned on the source to simulate microgravity. The activity of the source was established using the Bateman formula. The spectrum of the source, calculated according to the natural decrease of radioactivity and the gamma spectrometry, showed very good adequacy. The experimental fluence was close to the theoretical fluence evaluation, attesting its uniform distribution. A Monte Carlo model of the irradiation device was processed by GATE code. Dosimetry was performed with radiophotoluminescent dosimeters exposed for one month at different locations (x and y axes) in various cell culture conditions. Using the RPM placed on the source, we reached a mean absorbed dose of gamma rays of (0.33 ± 0.17) mSv per day. In conclusion, we have elaborated an innovative device allowing chronic radiation exposure to be combined with altered gravity. Given the limited access to the International Space Station, this device could be useful to researchers interested in the field of space biology.

  9. Bio-Inspired Multi-Functional Drug Transport Design Concept and Simulations.

    PubMed

    Pidaparti, Ramana M; Cartin, Charles; Su, Guoguang

    2017-04-25

    In this study, we developed a microdevice concept for drug/fluidic transport taking an inspiration from supramolecular motor found in biological cells. Specifically, idealized multi-functional design geometry (nozzle/diffuser/nozzle) was developed for (i) fluidic/particle transport; (ii) particle separation; and (iii) droplet generation. Several design simulations were conducted to demonstrate the working principles of the multi-functional device. The design simulations illustrate that the proposed design concept is feasible for multi-functionality. However, further experimentation and optimization studies are needed to fully evaluate the multifunctional device concept for multiple applications.

  10. Influence of electronic apex locators and a gutta-percha heating device on implanted cardiac devices: an in vivo study.

    PubMed

    Moraes, A P; Silva, E J; Lamas, C C; Portugal, P H; Neves, A A

    2016-06-01

    To evaluate the potential for electromagnetic interference (EMI) of electronic apex locators (EALs) and a gutta-percha heating device (HD) in patients with implantable cardiac pacemakers (ICPs) or cardioverter-defibrillators (ICDs). Two types of EALs (Romiapex A-15 and Novapex) and a HD (Touch'n Heat) were tested in patients followed in an outpatient clinic for cardiac arrhythmias. The heart rhythm was monitored on a computer screen during all experimental phases. After baseline data collection, the patient held each appliance (turned on) for 30 s, simulating their clinical use. If background noise was detected on the cardiac monitor, the sensitivity of the ICP/ICD was lowered by the cardiologist to evaluate the intensity of the detected EMI. Twelve patients were evaluated (5 female and 7 male), and in nine instances, background noise in their cardiac devices related to the use of the endodontic devices was detected (6 patients). After lowering the sensitivity of the cardiac implants, three patients had more severe EMI in six instances, including pauses in ICP function. The presence of a symptomatic or asymptomatic pause was related to the patient's underlying heart rhythm. The HD device produced background noise more often compared to EALs. These were associated with more severe types of EMI. The EALs and gutta-percha HD were capable of causing background noise detection or pauses in cardiac implants in vivo. The use of electronic dental devices nearby patients with cardiac implants should be carefully considered in clinical practice. © 2015 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  11. Fluidic Vectoring of a Planar Incompressible Jet Flow

    NASA Astrophysics Data System (ADS)

    Mendez, Miguel Alfonso; Scelzo, Maria Teresa; Enache, Adriana; Buchlin, Jean-Marie

    2018-06-01

    This paper presents an experimental, a numerical and a theoretical analysis of the performances of a fluidic vectoring device for controlling the direction of a turbulent, bi-dimensional and low Mach number (incompressible) jet flow. The investigated design is the co-flow secondary injection with Coanda surface, which allows for vectoring angles up to 25° with no need of moving mechanical parts. A simple empirical model of the vectoring process is presented and validated via experimental and numerical data. The experiments consist of flow visualization and image processing for the automatic detection of the jet centerline; the numerical simulations are carried out solving the Unsteady Reynolds Average Navier- Stokes (URANS) closed with the k - ω SST turbulence model, using the PisoFoam solver from OpenFOAM. The experimental validation on three different geometrical configurations has shown that the model is capable of providing a fast and reliable evaluation of the device performance as a function of the operating conditions.

  12. Test-retest reliability of a new device for assessing ankle joint threshold to detect passive movement in healthy adults.

    PubMed

    Sun, Wei; Song, Qipeng; Yu, Bing; Zhang, Cui; Mao, Dewei

    2015-01-01

    This study aimed to evaluate the test-retest reliability of a new device for assessing ankle joint kinesthesia. This device could measure the passive motion threshold of four ankle joint movements, namely plantarflexion, dorsiflexion, inversion and eversion. A total of 21 healthy adults, including 13 males and 8 females, participated in the study. Each participant completed two sessions on two separate days with 1-week interval. The sessions were administered by the same experimenter in the same laboratory. At least 12 trials (three successful trials in each of the four directions) were performed in each session. The mean values in each direction were calculated and analysed. The ICC values of test-retest reliability ranged from 0.737 (dorsiflexion) to 0.935 (eversion), whereas the SEM values ranged from 0.21° (plantarflexion) to 0.52° (inversion). The Bland-Altman plots showed that the reliability of plantarflexion-dorsiflexion was better than that of inversion-eversion. The results evaluated the reliability of the new device as fair to excellent. The new device for assessing kinesthesia could be used to examine the ankle joint kinesthesia.

  13. An acoustic charge transport imager for high definition television applications

    NASA Technical Reports Server (NTRS)

    Hunt, William D.; Brennan, Kevin F.; Summers, Christopher J.

    1993-01-01

    This report covers: (1) invention of a new, ultra-low noise, low operating voltage APD which is expected to offer far better performance than the existing volume doped APD device; (2) performance of a comprehensive series of experiments on the acoustic and piezoelectric properties of ZnO films sputtered on GaAs which can possibly lead to a decrease in the required rf drive power for ACT devices by 15dB; (3) development of an advanced, hydrodynamic, macroscopic simulator used for evaluating the performance of ACT and CTD devices and aiding in the development of the next generation of devices; (4) experimental development of CTD devices which utilize a p-doped top barrier demonstrating charge storage capacity and low leakage currents; (5) refinements in materials growth techniques and in situ controls to lower surface defect densities to record levels as well as increase material uniformity and quality.

  14. Design, characterisation and evaluation of a soft robotic sock device on healthy subjects for assisted ankle rehabilitation.

    PubMed

    Low, Fan-Zhe; Lim, Jeong Hoon; Yeow, Chen-Hua

    2018-01-01

    Motor impairment is one of the common neurological conditions suffered by stroke patients, where this chronic immobility together with the absence of early limb mobilisation can lead to conditions such as joint contracture with spastic limbs. In this study, a soft robotic sock device was developed, which can provide compliant actuation to the ankle joint in the early stage of stroke recovery. The device is fitted with soft extension actuators and when the actuators are inflated, they extend and guide the foot into plantarflexion; upon deflation, the actuators will resume their initial conformations. Each actuator is linked to a pneumatic pump-valve control system that injects pressurised air into or release air from the system. In this study, the design and characterisation of the soft actuators will be presented, where the theoretical and experimental forces generated by the actuators were compared. The performance of the device was also evaluated on healthy subjects and the results had shown that the device was able to move the subjects' ankles into cycles of dorsiflexion-plantarflexion, in the absence of voluntary muscle effort. The findings suggested that the soft wearable robotic device was capable of assisting the subjects in performing repeated cycles of ankle flexion.

  15. General method to evaluate substrate surface modification techniques for light extraction enhancement of organic light emitting diodes

    NASA Astrophysics Data System (ADS)

    Krummacher, B. C.; Mathai, M. K.; Choong, V.; Choulis, S. A.; So, F.; Winnacker, A.

    2006-09-01

    The external light output of organic light emitting diodes (OLEDs) can be increased by modifying the light emitting surface. The apparent light extraction enhancement is given by the ratio between the efficiency of the unmodified device and the efficiency of the modified device. This apparent light extraction enhancement is dependent on the OLED architecture itself and is not the correct value to judge the effectiveness of a technique to enhance light outcoupling due to substrate surface modification. We propose a general method to evaluate substrate surface modification techniques for light extraction enhancement of OLEDs independent from the device architecture. This method is experimentally demonstrated using green electrophosphorescent OLEDs with different device architectures. The substrate surface of these OLEDs was modified by applying a prismatic film to increase light outcoupling from the device stack. It was demonstrated that the conventionally measured apparent light extraction enhancement by means of the prismatic film does not reflect the actual performance of the light outcoupling technique. Rather, by comparing the light extracted out of the prismatic film to that generated in the OLED layers and coupled into the substrate (before the substrate/air interface), a more accurate evaluation of light outcoupling enhancement can be achieved. Furthermore we show that substrate surface modification can change the output spectrum of a broad band emitting OLED.

  16. Gas-fired duplex free-piston Stirling refrigerator

    NASA Astrophysics Data System (ADS)

    Urieli, L.

    1984-03-01

    The duplex free-piston Stirling refrigerator is a potentially high efficiency, high reliability device which is ideally suited to the home appliance field, in particular as a gas-fired refrigerator. It has significant advantages over other equivalent devices including freedom from halogenated hydrocarbons, extremely low temperatures available at a high efficiency, integrated water heating, and simple burner system control. The design and development of a portable working demonstration gas-fired duplex Stirling refrigeration unit is described. A unique combination of computer aided development and experimental development was used, enabling a continued interaction between the theoretical analysis and practical testing and evaluation. A universal test rig was developed in order to separately test and evaluate major subunits, enabling a smooth system integration phase.

  17. Evaluation of polymer based third order nonlinear integrated optics devices

    NASA Astrophysics Data System (ADS)

    Driessen, A.; Hoekstra, H. J. W. M.; Blom, F. C.; Horst, F.; Krijnen, G. J. M.; van Schoot, J. B. P.; Lambeck, P. V.; Popma, Th. J. A.; Diemeer, M. B.

    1998-01-01

    Nonlinear polymers are promising materials for high speed active integrated optics devices. In this paper we evaluate the perspectives polymer based nonlinear optical devices can offer. Special attention is directed to the materials aspects. In our experimental work we applied mainly Akzo Nobel DANS side-chain polymer that exhibits large second and third order coefficients. This material has been characterized by third harmonic generation, z-scan and pump-probe measurements. In addition, various waveguiding structures have been used to measure the nonlinear absorption (two photon absorption) on a ps time-scale. Finally an integrated optics Mach Zehnder interferometer has been realized and evaluated. It is shown that the DANS side-chain polymer has many of the desired properties: the material is easily processable in high-quality optical waveguiding structures, has low linear absorption and its nonlinearity has a pure electronic origin. More materials research has to be done to arrive at materials with higher nonlinear coefficients to allow switching at moderate light intensity ( < 1 W peak power) and also with lower nonlinear absorption coefficients.

  18. Development and performance evaluation of an MR squeeze-mode damper

    NASA Astrophysics Data System (ADS)

    Sapiński, Bogdan; Gołdasz, Janusz

    2015-11-01

    In this paper the authors present results of a magnetorheological (MR) damper prototype development and performance evaluation study. The damper is a device functioning in the so-called squeeze-mode of MR fluid flow regime of operation. By principle, in a squeeze-mode damper the control (working) gap height varies according to the prescribed displacement or force input profile. Such hardware has been claimed to be well suited to small-amplitude vibration damping applications. However, it is still in its infancy. Its potential seems appealing yet unclear. Accordingly, the authors reveal performance figures of the damper complemented by numerical finite-element simulations of the electro-magnetic circuit of the device. The numerical results are presented in the form of maps of averaged magnetic flux density versus coil current and gap height as well as magnetic flux, inductance, and cogging force calculations, respectively. The simulated data are followed by experimental evaluation of the damper performance incorporating plots of force versus piston displacement (velocity) across a prescribed range of excitation inputs. Moreover, some insight into transient (unsteady) characteristics of the device is provided through testing results involving transient currents.

  19. An evaluation of the following too closely monitor system on a four-lane undivided highway : interim report.

    DOT National Transportation Integrated Search

    1976-01-01

    The FOLLOWING TOO CLOSELY (FTC) MONITOR system is an experimental device designed to measure vehicle gaps at a point along the highway and to advise the motorist, by means of a flashing message on a sign, that he is following the car in front of him ...

  20. Control of a haptic gear shifting assistance device utilizing a magnetorheological clutch

    NASA Astrophysics Data System (ADS)

    Han, Young-Min; Choi, Seung-Bok

    2014-10-01

    This paper proposes a haptic clutch driven gear shifting assistance device that can help when the driver shifts the gear of a transmission system. In order to achieve this goal, a magnetorheological (MR) fluid-based clutch is devised to be capable of the rotary motion of an accelerator pedal to which the MR clutch is integrated. The proposed MR clutch is then manufactured, and its transmission torque is experimentally evaluated according to the magnetic field intensity. The manufactured MR clutch is integrated with the accelerator pedal to transmit a haptic cue signal to the driver. The impending control issue is to cue the driver to shift the gear via the haptic force. Therefore, a gear-shifting decision algorithm is constructed by considering the vehicle engine speed concerned with engine combustion dynamics, vehicle dynamics and driving resistance. Then, the algorithm is integrated with a compensation strategy for attaining the desired haptic force. In this work, the compensator is also developed and implemented through the discrete version of the inverse hysteretic model. The control performances, such as the haptic force tracking responses and fuel consumption, are experimentally evaluated.

  1. Understanding biomaterial-tissue interface quality: combined in vitro evaluation

    NASA Astrophysics Data System (ADS)

    Gasik, Michael

    2017-12-01

    One of the greatest challenges in the development of new medical products and devices remains in providing maximal patient safety, efficacy and suitability for the purpose. A 'good quality' of the tissue-implant interface is one of the most critical factors for the success of the implant integration. In this paper this challenge is being discussed from the point of view of basic stimuli combination to experimental testing. The focus is in particular on bacterial effects on tissue-implant interaction (for different materials). The demonstration of the experimental evaluation of the tissue-implant interface is for dental abutment with mucosal contact. This shows that testing of the interface quality could be the most relevant in controlled conditions, which mimic as possible the clinical applications, but consider variables being under the control of the evaluator.

  2. Performance evaluation of a piezoactuator-based single-stage valve system subjected to high temperature

    NASA Astrophysics Data System (ADS)

    Jeon, Juncheol; Han, Chulhee; Chung, Jye Ung; Choi, Seung-Bok

    2015-01-01

    In this paper, a novel single-stage valve system activated by a piezostack actuator is proposed and experimentally evaluated at both room temperature (20 °C) and high temperature (100 °C) conditions. A hinge-lever displacement amplifier is adopted in the valve system to magnify the displacement generated from the piezostack actuator. After explaining the operating principle of the proposed piezostack-driven single-stage valve system, the geometric dimensions and mechanical properties of the valve components are discussed in details. An experimental apparatus is then manufactured to evaluate the performances of the valve system such as flow rate. The experimental apparatus consists of a heat chamber, which can regulate the temperature of the valve system and oil, pneumatic-hydraulic cylinders, a hydraulic circuit, a pneumatic circuit, electronic devices, an interface card, and a high voltage amplifier. The pneumatic-hydraulic cylinder transforms the pneumatic pressure into hydraulic pressure. The performances of the valve system regarding spool response, pressure drop, and flow rate are evaluated and presented. In addition, the performance of the valve system under high temperature condition is compared with that under room temperature condition. The experimental results are plotted in both frequency and time domains.

  3. A device for high-throughput monitoring of degradation in soft tissue samples.

    PubMed

    Tzeranis, D S; Panagiotopoulos, I; Gkouma, S; Kanakaris, G; Georgiou, N; Vaindirlis, N; Vasileiou, G; Neidlin, M; Gkousioudi, A; Spitas, V; Macheras, G A; Alexopoulos, L G

    2018-06-06

    This work describes the design and validation of a novel device, the High-Throughput Degradation Monitoring Device (HDD), for monitoring the degradation of 24 soft tissue samples over incubation periods of several days inside a cell culture incubator. The device quantifies sample degradation by monitoring its deformation induced by a static gravity load. Initial instrument design and experimental protocol development focused on quantifying cartilage degeneration. Characterization of measurement errors, caused mainly by thermal transients and by translating the instrument sensor, demonstrated that HDD can quantify sample degradation with <6 μm precision and <10 μm temperature-induced errors. HDD capabilities were evaluated in a pilot study that monitored the degradation of fresh ex vivo human cartilage samples by collagenase solutions over three days. HDD could robustly resolve the effects of collagenase concentration as small as 0.5 mg/ml. Careful sample preparation resulted in measurements that did not suffer from donor-to-donor variation (coefficient of variance <70%). Due to its unique combination of sample throughput, measurement precision, temporal sampling and experimental versality, HDD provides a novel biomechanics-based experimental platform for quantifying the effects of proteins (cytokines, growth factors, enzymes, antibodies) or small molecules on the degradation of soft tissues or tissue engineering constructs. Thereby, HDD can complement established tools and in vitro models in important applications including drug screening and biomaterial development. Copyright © 2018 Elsevier Ltd. All rights reserved.

  4. Comparison of clinical parameters and environmental noise levels between regular surgery and piezosurgery for extraction of impacted third molars.

    PubMed

    Chang, Hao-Hueng; Lee, Ming-Shu; Hsu, You-Chyun; Tsai, Shang-Jye; Lin, Chun-Pin

    2015-10-01

    Impacted third molars can be extracted by regular surgery or piezosurgery. The aim of this study was to compare clinical parameters and device-produced noise levels between regular surgery and piezosurgery for the extraction of impacted third molars. Twenty patients (18 women and 2 men, 17-29 years of age) with bilateral symmetrical impacted mandibular or maxillary third molars of the same level were included in this randomized crossover clinical trial. The 40 impacted third molars were divided into a control group (n = 20), in which the third molar was extracted by regular surgery using a high-speed handpiece and an elevator, and an experimental group (n = 20), in which the third molar was extracted by piezosurgery using a high-speed handpiece and a piezotome. The clinical parameters were evaluated by a self-reported questionnaire. The noise levels produced by the high-speed handpiece and piezotome were measured and compared between the experimental and control groups. Patients in the experimental group had a better feeling about tooth extraction and force delivery during extraction and less facial swelling than patients in the control group. However, there were no significant differences in noise-related disturbance, extraction period, degree of facial swelling, pain score, pain duration, any noise levels produced by the devices under different circumstances during tooth extraction between the control and experimental groups. The piezosurgery device produced noise levels similar to or lower than those of the high-speed drilling device. However, piezosurgery provides advantages of increased patient comfort during extraction of impacted third molars. Copyright © 2014. Published by Elsevier B.V.

  5. Photocarrier extraction in GaAsSb/GaAsN type-II QW superlattice solar cells

    NASA Astrophysics Data System (ADS)

    Aeberhard, U.; Gonzalo, A.; Ulloa, J. M.

    2018-05-01

    Photocarrier transport and extraction in GaAsSb/GaAsN type-II quantum well superlattices are investigated by means of inelastic quantum transport calculations based on the non-equilibrium Green's function formalism. Evaluation of the local density of states and the spectral current flow enables the identification of different regimes for carrier localization, transport, and extraction as a function of configurational parameters. These include the number of periods, the thicknesses of the individual layers in one period, the built-in electric field, and the temperature of operation. The results for the carrier extraction efficiency are related to experimental data for different symmetric GaAsSb/GaAsN type-II quantum well superlattice solar cell devices and provide a qualitative explanation for the experimentally observed dependence of photovoltaic device performance on the period thickness.

  6. The High-efficiency LED Driver for Visible Light Communication Applications.

    PubMed

    Gong, Cihun-Siyong Alex; Lee, Yu-Chen; Lai, Jyun-Liang; Yu, Chueh-Hao; Huang, Li Ren; Yang, Chia-Yen

    2016-08-08

    This paper presents a LED driver for VLC. The main purpose is to solve the low data rate problem used to be in switching type LED driver. The GaN power device is proposed to replace the traditional silicon power device of switching LED driver for the purpose of increasing switching frequency of converter, thereby increasing the bandwidth of data transmission. To achieve high efficiency, the diode-connected GaN power transistor is utilized to replace the traditional ultrafast recovery diode used to be in switching type LED driver. This work has been experimentally evaluated on 350-mA output current. The results demonstrate that it supports the data of PWM dimming level encoded in the PPM scheme for VLC application. The experimental results also show that system's efficiency of 80.8% can be achieved at 1-Mb/s data rate.

  7. Development of haptic system for surgical robot

    NASA Astrophysics Data System (ADS)

    Gang, Han Gyeol; Park, Jiong Min; Choi, Seung-Bok; Sohn, Jung Woo

    2017-04-01

    In this paper, a new type of haptic system for surgical robot application is proposed and its performances are evaluated experimentally. The proposed haptic system consists of an effective master device and a precision slave robot. The master device has 3-DOF rotational motion as same as human wrist motion. It has lightweight structure with a gyro sensor and three small-sized MR brakes for position measurement and repulsive torque generation, respectively. The slave robot has 3-DOF rotational motion using servomotors, five bar linkage and a torque sensor is used to measure resistive torque. It has been experimentally demonstrated that the proposed haptic system has good performances on tracking control of desired position and repulsive torque. It can be concluded that the proposed haptic system can be effectively applied to the surgical robot system in real field.

  8. Design and evaluation of cellular power converter architectures

    NASA Astrophysics Data System (ADS)

    Perreault, David John

    Power electronic technology plays an important role in many energy conversion and storage applications, including machine drives, power supplies, frequency changers and UPS systems. Increases in performance and reductions in cost have been achieved through the development of higher performance power semiconductor devices and integrated control devices with increased functionality. Manufacturing techniques, however, have changed little. High power is typically achieved by paralleling multiple die in a sing!e package, producing the physical equivalent of a single large device. Consequently, both the device package and the converter in which the device is used continue to require large, complex mechanical structures, and relatively sophisticated heat transfer systems. An alternative to this approach is the use of a cellular power converter architecture, which is based upon the parallel connection of a large number of quasi-autonomous converters, called cells, each of which is designed for a fraction of the system rating. The cell rating is chosen such that single-die devices in inexpensive packages can be used, and the cell fabricated with an automated assembly process. The use of quasi-autonomous cells means that system performance is not compromised by the failure of a cell. This thesis explores the design of cellular converter architectures with the objective of achieving improvements in performance, reliability, and cost over conventional converter designs. New approaches are developed and experimentally verified for highly distributed control of cellular converters, including methods for ripple cancellation and current-sharing control. The performance of these techniques are quantified, and their dynamics are analyzed. Cell topologies suitable to the cellular architecture are investigated, and their use for systems in the 5-500 kVA range is explored. The design, construction, and experimental evaluation of a 6 kW cellular switched-mode rectifier is also addressed. This cellular system implements entirely distributed control, and achieves performance levels unattainable with an equivalent single converter. (Copies available exclusively from MIT Libraries, Rm. 14-0551, Cambridge, MA 02139-4307. Ph. 617-253-5668; Fax 617-253-1690.)

  9. Conceptual achievement of 1GBq activity in a Plasma Focus driven system.

    PubMed

    Tabbakh, Farshid; Sadat Kiai, Seyed Mahmood; Pashaei, Mohammad

    2017-11-01

    This is an approach to evaluate the radioisotope production by means of typical dense plasma focus devices. The production rate of the appropriate positron emitters, F-18, N-13 and O-15 has been studied. The beam-target mechanism was simulated by GEANT4 Monte Carlo tool using QGSP_BIC and QGSP_INCLXX physic models as comparison. The results for positron emitters have been evaluated by reported experimental data and found conformity between simulations and experimental reports that leads to using this code as a reliable tool in optimizing the DPF driven systems for achieving to 1GBq activity of produced radioisotope. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Design, construction and testing of annular diffusers for high speed civil transportation combustor applications

    NASA Technical Reports Server (NTRS)

    Okhio, Cyril B.

    1995-01-01

    A theoretical and an experimental design study of subsonic flow through curved-wall annular diffusers is being carried out in order to establish the most pertinent design parameters for such devices and the implications of their application in the design of engine components in the aerospace industries. This investigation consists of solving numerically the full Navier Stokes and Continuity equations for the time-mean flow. Various models of turbulence are being evaluated for adoption throughout the study and comparisons would be made with experimental data where they exist. Assessment of diffuser performance based on the dissipated mechanical energy would also be made. The experimental work involves the application of Computer Aided Design software tool to the development of a suitable annular diffuser geometry and the subsequent downloading of such data to a CNC machine at Central State University. The results of the investigations are expected to indicate that more cost effective component design of such devices as effective component design of such devices as diffusers which normally contain complex flows can still be achieved. In this regard a review paper was accepted and presented at the First International Conference on High Speed Civil Transportation Research held at North Carolina A&T in December of 1994.

  11. Finite element strategies to satisfy clinical and engineering requirements in the field of percutaneous valves.

    PubMed

    Capelli, Claudio; Biglino, Giovanni; Petrini, Lorenza; Migliavacca, Francesco; Cosentino, Daria; Bonhoeffer, Philipp; Taylor, Andrew M; Schievano, Silvia

    2012-12-01

    Finite element (FE) modelling can be a very resourceful tool in the field of cardiovascular devices. To ensure result reliability, FE models must be validated experimentally against physical data. Their clinical application (e.g., patients' suitability, morphological evaluation) also requires fast simulation process and access to results, while engineering applications need highly accurate results. This study shows how FE models with different mesh discretisations can suit clinical and engineering requirements for studying a novel device designed for percutaneous valve implantation. Following sensitivity analysis and experimental characterisation of the materials, the stent-graft was first studied in a simplified geometry (i.e., compliant cylinder) and validated against in vitro data, and then in a patient-specific implantation site (i.e., distensible right ventricular outflow tract). Different meshing strategies using solid, beam and shell elements were tested. Results showed excellent agreement between computational and experimental data in the simplified implantation site. Beam elements were found to be convenient for clinical applications, providing reliable results in less than one hour in a patient-specific anatomical model. Solid elements remain the FE choice for engineering applications, albeit more computationally expensive (>100 times). This work also showed how information on device mechanical behaviour differs when acquired in a simplified model as opposed to a patient-specific model.

  12. Evaluation of Relative Sensitivity of SAW and Flexural Plate Wave Devices for Atmospheric Sensing

    NASA Technical Reports Server (NTRS)

    White, Richard M.; Black, Justin; Chen, Bryan

    1998-01-01

    The objective of this project is to evaluate the suitability of the ultrasonic flexural plate wave (FPW) device as the detector in a gas chromatograph (GC). Of particular interest is the detection of nitrous oxide (N2O). From experimental results we conclude analyte detection is achieved through two mechanisms: changes in gas density, and mass loading of the device membrane due to the sorption of gas molecules. Reducing the dead volume of the FPW chamber increased the FPW response. A comparison of the FPW response to that of the surface acoustic wave (SAW) detector provided with the GC (made by MSI, Microsensor Technologies, Inc.), shows that for unseparated N2O in N2, the FPW exhibits a sensitivity that is at least 550 times greater than that of the SAW device. A Porapak Q column was found to separate N2O from its carrier gas, N2 or He. With the Porapak Q column, a coated FPW detected 1 ppm N2O in N2 or He, with a response magnitude of 7 Hz. A coated SAW exhibited a response of 25 Hz to pure N2O. The minimal detectable N2O concentrations of the sensors were not evaluated.

  13. A Review of Numerical Simulation and Analytical Modeling for Medical Devices Safety in MRI

    PubMed Central

    Kabil, J.; Belguerras, L.; Trattnig, S.; Pasquier, C.; Missoffe, A.

    2016-01-01

    Summary Objectives To review past and present challenges and ongoing trends in numerical simulation for MRI (Magnetic Resonance Imaging) safety evaluation of medical devices. Methods A wide literature review on numerical and analytical simulation on simple or complex medical devices in MRI electromagnetic fields shows the evolutions through time and a growing concern for MRI safety over the years. Major issues and achievements are described, as well as current trends and perspectives in this research field. Results Numerical simulation of medical devices is constantly evolving, supported by calculation methods now well-established. Implants with simple geometry can often be simulated in a computational human model, but one issue remaining today is the experimental validation of these human models. A great concern is to assess RF heating on implants too complex to be traditionally simulated, like pacemaker leads. Thus, ongoing researches focus on alternative hybrids methods, both numerical and experimental, with for example a transfer function method. For the static field and gradient fields, analytical models can be used for dimensioning simple implants shapes, but limited for complex geometries that cannot be studied with simplifying assumptions. Conclusions Numerical simulation is an essential tool for MRI safety testing of medical devices. The main issues remain the accuracy of simulations compared to real life and the studies of complex devices; but as the research field is constantly evolving, some promising ideas are now under investigation to take up the challenges. PMID:27830244

  14. Gas transfer model to design a ventilator for neonatal total liquid ventilation.

    PubMed

    Bonfanti, Mirko; Cammi, Antonio; Bagnoli, Paola

    2015-12-01

    The study was aimed to optimize the gas transfer in an innovative ventilator for neonatal Total Liquid Ventilation (TLV) that integrates the pumping and oxygenation functions in a non-volumetric pulsatile device made of parallel flat silicone membranes. A computational approach was adopted to evaluate oxygen (O2) and carbon dioxide (CO2) exchanges between the liquid perfluorocarbon (PFC) and the oxygenating gas, as a function of the geometrical parameter of the device. A 2D semi-empirical model was implemented to this purpose using Comsol Multiphysics to study both the fluid dynamics and the gas exchange in the ventilator. Experimental gas exchanges measured with a preliminary prototype were compared to the simulation outcomes to prove the model reliability. Different device configurations were modeled to identify the optimal design able to guarantee the desired gas transfer. Good agreement between experimental and simulation outcomes was obtained, validating the model. The optimal configuration, able to achieve the desired gas exchange (ΔpCO2 = 16.5 mmHg and ΔpO2 = 69 mmHg), is a device comprising 40 modules, 300 mm in length (total exchange area = 2.28 m(2)). With this configuration gas transfer performance is satisfactory for all the simulated settings, proving good adaptability of the device. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.

  15. Use of the FDA nozzle model to illustrate validation techniques in computational fluid dynamics (CFD) simulations

    PubMed Central

    Hariharan, Prasanna; D’Souza, Gavin A.; Horner, Marc; Morrison, Tina M.; Malinauskas, Richard A.; Myers, Matthew R.

    2017-01-01

    A “credible” computational fluid dynamics (CFD) model has the potential to provide a meaningful evaluation of safety in medical devices. One major challenge in establishing “model credibility” is to determine the required degree of similarity between the model and experimental results for the model to be considered sufficiently validated. This study proposes a “threshold-based” validation approach that provides a well-defined acceptance criteria, which is a function of how close the simulation and experimental results are to the safety threshold, for establishing the model validity. The validation criteria developed following the threshold approach is not only a function of Comparison Error, E (which is the difference between experiments and simulations) but also takes in to account the risk to patient safety because of E. The method is applicable for scenarios in which a safety threshold can be clearly defined (e.g., the viscous shear-stress threshold for hemolysis in blood contacting devices). The applicability of the new validation approach was tested on the FDA nozzle geometry. The context of use (COU) was to evaluate if the instantaneous viscous shear stress in the nozzle geometry at Reynolds numbers (Re) of 3500 and 6500 was below the commonly accepted threshold for hemolysis. The CFD results (“S”) of velocity and viscous shear stress were compared with inter-laboratory experimental measurements (“D”). The uncertainties in the CFD and experimental results due to input parameter uncertainties were quantified following the ASME V&V 20 standard. The CFD models for both Re = 3500 and 6500 could not be sufficiently validated by performing a direct comparison between CFD and experimental results using the Student’s t-test. However, following the threshold-based approach, a Student’s t-test comparing |S-D| and |Threshold-S| showed that relative to the threshold, the CFD and experimental datasets for Re = 3500 were statistically similar and the model could be considered sufficiently validated for the COU. However, for Re = 6500, at certain locations where the shear stress is close the hemolysis threshold, the CFD model could not be considered sufficiently validated for the COU. Our analysis showed that the model could be sufficiently validated either by reducing the uncertainties in experiments, simulations, and the threshold or by increasing the sample size for the experiments and simulations. The threshold approach can be applied to all types of computational models and provides an objective way of determining model credibility and for evaluating medical devices. PMID:28594889

  16. Use of the FDA nozzle model to illustrate validation techniques in computational fluid dynamics (CFD) simulations.

    PubMed

    Hariharan, Prasanna; D'Souza, Gavin A; Horner, Marc; Morrison, Tina M; Malinauskas, Richard A; Myers, Matthew R

    2017-01-01

    A "credible" computational fluid dynamics (CFD) model has the potential to provide a meaningful evaluation of safety in medical devices. One major challenge in establishing "model credibility" is to determine the required degree of similarity between the model and experimental results for the model to be considered sufficiently validated. This study proposes a "threshold-based" validation approach that provides a well-defined acceptance criteria, which is a function of how close the simulation and experimental results are to the safety threshold, for establishing the model validity. The validation criteria developed following the threshold approach is not only a function of Comparison Error, E (which is the difference between experiments and simulations) but also takes in to account the risk to patient safety because of E. The method is applicable for scenarios in which a safety threshold can be clearly defined (e.g., the viscous shear-stress threshold for hemolysis in blood contacting devices). The applicability of the new validation approach was tested on the FDA nozzle geometry. The context of use (COU) was to evaluate if the instantaneous viscous shear stress in the nozzle geometry at Reynolds numbers (Re) of 3500 and 6500 was below the commonly accepted threshold for hemolysis. The CFD results ("S") of velocity and viscous shear stress were compared with inter-laboratory experimental measurements ("D"). The uncertainties in the CFD and experimental results due to input parameter uncertainties were quantified following the ASME V&V 20 standard. The CFD models for both Re = 3500 and 6500 could not be sufficiently validated by performing a direct comparison between CFD and experimental results using the Student's t-test. However, following the threshold-based approach, a Student's t-test comparing |S-D| and |Threshold-S| showed that relative to the threshold, the CFD and experimental datasets for Re = 3500 were statistically similar and the model could be considered sufficiently validated for the COU. However, for Re = 6500, at certain locations where the shear stress is close the hemolysis threshold, the CFD model could not be considered sufficiently validated for the COU. Our analysis showed that the model could be sufficiently validated either by reducing the uncertainties in experiments, simulations, and the threshold or by increasing the sample size for the experiments and simulations. The threshold approach can be applied to all types of computational models and provides an objective way of determining model credibility and for evaluating medical devices.

  17. Design, Modeling, Fabrication, and Evaluation of the Air Amplifier for Improved Detection of Biomolecules by Electrospray Ionization Mass Spectrometry

    PubMed Central

    Robichaud, Guillaume; Dixon, R. Brent; Potturi, Amarnatha S.; Cassidy, Dan; Edwards, Jack R.; Sohn, Alex; Dow, Thomas A.; Muddiman, David C.

    2010-01-01

    Through a multi-disciplinary approach, the air amplifier is being evolved as a highly engineered device to improve detection limits of biomolecules when using electrospray ionization. Several key aspects have driven the modifications to the device through experimentation and simulations. We have developed a computer simulation that accurately portrays actual conditions and the results from these simulations are corroborated by the experimental data. These computer simulations can be used to predict outcomes from future designs resulting in a design process that is efficient in terms of financial cost and time. We have fabricated a new device with annular gap control over a range of 50 to 70 μm using piezoelectric actuators. This has enabled us to obtain better aerodynamic performance when compared to the previous design (2× more vacuum) and also more reproducible results. This is allowing us to study a broader experimental space than the previous design which is critical in guiding future directions. This work also presents and explains the principles behind a fractional factorial design of experiments methodology for testing a large number of experimental parameters in an orderly and efficient manner to understand and optimize the critical parameters that lead to obtain improved detection limits while minimizing the number of experiments performed. Preliminary results showed that several folds of improvements could be obtained for certain condition of operations (up to 34 folds). PMID:21499524

  18. A new mechanical device for circular compression anastomosis. Preliminary results of animal and clinical experimentation.

    PubMed Central

    Rosati, R; Rebuffat, C; Pezzuoli, G

    1988-01-01

    The authors report the preliminary results obtained in animal and clinical experimentation of a new mechanical device for circular anastomosis which they have developed. It is a gun that places an apparatus consisting of three polypropylene rings that, through the compression among them of the severed edges of the bowel, realize a sutureless anastomosis and are spontaneously evacuated. Fifty-eight colonic anastomoses were performed in dogs with this device; 23 stapled colonic anastomoses were also executed concurrently. Forty-four animals underwent a relaparotomy to remove the colonic specimen containing the anastomoses. Bursting pressure and the histologic features of the anastomoses were evaluated at different time intervals after operation. A good healing of all compression anastomoses was observed, thereby allowing them to initiate the experience in humans. Thirteen anastomoses (6 colorectal extraperitoneal, 1 colorectal intraperitoneal, 5 colocolonic, 1 ileorectal) were performed at the 1st Surgical Department, Milan University. One subclinical leakage (7.7%) spontaneously healed in a few days. No stenoses were observed. Images Fig. 1. Fig. 2., Fig. 4., Fig. 6. Fig. 3., Fig. 5., Fig. 7. Fig. 8. Fig. 9. PMID:3345111

  19. [Telerehabilitation to treat stress urinary incontinence. Pilot study].

    PubMed

    Carrión Pérez, Francisca; Rodríguez Moreno, María Sofía; Carnerero Córdoba, Lidia; Romero Garrido, Marina C; Quintana Tirado, Laura; García Montes, Inmaculada

    2015-05-21

    We aimed to test a new telerehabilitation device for stress urinary incontinence (SUI) in order to make an initial assessment of its effectiveness. Randomized, controlled pilot study. experimental group (10 patients): pelvic floor muscle training, device training and home treatment with it; control group (9 patients): conventional rehabilitation treatment. Outcome measures (baseline and 3 months) overall and specific quality of life: International Consultation Incontinence Questionnaire and King's Health Questionnaire, bladder diary, perineometry, satisfaction with the program and degree of compliance. Baseline characteristics were similar in both groups. There was no statistically significant difference for any outcome measures between groups at the end of the follow-up. The change in perineometry values at baseline and after the intervention was significant in the experimental group (23.06 to 32.00, P=.011). No group in this study had any serious adverse effects. The tested device is safe and well accepted. Although there is some evidence of its efficacy in the rehabilitation treatment of SUI, larger trials are needed to appropriately evaluate the potential advantages. Copyright © 2014 Elsevier España, S.L.U. All rights reserved.

  20. Phase Conjugated and Transparent Wavelength Conversions of Nyquist 16-QAM Signals Employing a Single-Layer Graphene Coated Fiber Device

    PubMed Central

    Hu, Xiao; Zeng, Mengqi; Long, Yun; Liu, Jun; Zhu, Yixiao; Zou, Kaiheng; Zhang, Fan; Fu, Lei; Wang, Jian

    2016-01-01

    We fabricate a nonlinear optical device based on a fiber pigtail cross-section coated with a single-layer graphene grown by chemical vapor deposition (CVD) method. Using the fabricated graphene-assisted nonlinear optical device and employing Nyquist 16-ary quadrature amplitude modulation (16-QAM) signal, we experimentally demonstrate phase conjugated wavelength conversion by degenerate four-wave mixing (FWM) and transparent wavelength conversion by non-degenerate FWM in graphene. We study the conversion efficiency as functions of the pump power and pump wavelength and evaluate the bit-error rate (BER) performance. We also compare the time-varying symbol sequence for graphene-assisted phase conjugated and transparent wavelength conversions of Nyquist 16-QAM signal. PMID:26932470

  1. Fracture Probability of MEMS Optical Devices for Space Flight Applications

    NASA Technical Reports Server (NTRS)

    Fettig, Rainer K.; Kuhn, Jonathan L.; Moseley, S. Harvey; Kutyrev, Alexander S.; Orloff, Jon

    1999-01-01

    A bending fracture test specimen design is presented for thin elements used in optical devices for space flight applications. The specimen design is insensitive to load position, avoids end effect complications, and can be used to measure strength of membranes less than 2 microns thick. The theoretical equations predicting stress at failure are presented, and a detailed finite element model is developed to validate the equations for this application. An experimental procedure using a focused ion beam machine is outlined, and results from preliminary tests of 1.9 microns thick single crystal silicon are presented. These tests are placed in the context of a methodology for the design and evaluation of mission critical devices comprised of large arrays of cells.

  2. Polymer coating behavior of Rayleigh-SAW resonators with gold electrode structure for gas sensor applications.

    PubMed

    Avramov, Ivan D; Länge, Kerstin; Rupp, Swen; Rapp, Bastian; Rapp, Michael

    2007-01-01

    Results from systematic polymer coating experiments on surface acoustic wave (SAW) resonators and coupled resonator filters (CRF) on ST-cut quartz with a corrosion-proof electrode structure entirely made of gold (Au) are presented and compared with data from similar SAW devices using aluminium (Al) electrodes. The recently developed Au devices are intended to replace their earlier Al counterparts in sensor systems operating in highly reactive chemical gas environments. Solid parylene C and soft poly[chlorotrifluoroethylene-co-vinylidene fluoride] (PCFV) polymer films are deposited under identical conditions onto the surface of Al and Au devices. The electrical performance of the Parylene C coated devices is monitored online during film deposition. The PCVF coated devices are evaluated after film deposition. The experimental data show that the Au devices can stand up to 40% thicker solid films for the same amount of loss increase than the Al devices and retain better resonance and phase characteristics. The frequency sensitivities of Au and Al devices to parylene C deposition are nearly identical. After coating with soft PCFV sensing film, the Au devices provide up to two times higher gas sensitivity when probed with cooling agent, octane, or tetrachloroethylene.

  3. Interacting with notebook input devices: an analysis of motor performance and users' expertise.

    PubMed

    Sutter, Christine; Ziefle, Martina

    2005-01-01

    In the present study the usability of two different types of notebook input devices was examined. The independent variables were input device (touchpad vs. mini-joystick) and user expertise (expert vs. novice state). There were 30 participants, of whom 15 were touchpad experts and the other 15 were mini-joystick experts. The experimental tasks were a point-click task (Experiment 1) and a point-drag-drop task (Experiment 2). Dependent variables were the time and accuracy of cursor control. To assess carryover effects, we had the participants complete both experiments, using not only the input device for which they were experts but also the device for which they were novices. Results showed the touchpad performance to be clearly superior to mini-joystick performance. Overall, experts showed better performance than did novices. The significant interaction of input device and expertise showed that the use of an unknown device is difficult, but only for touchpad experts, who were remarkably slower and less accurate when using a mini-joystick. Actual and potential applications of this research include an evaluation of current notebook input devices. The outcomes allow ergonomic guidelines to be derived for optimized usage and design of the mini-joystick and touchpad devices.

  4. Experimental Evaluation and Comparison of Thermal Conductivity of High-Voltage Insulation Materials for Vacuum Electronic Devices

    NASA Astrophysics Data System (ADS)

    Suresh, C.; Srikrishna, P.

    2017-07-01

    Vacuum electronic devices operate with very high voltage differences between their sub-assemblies which are separated by very small distances. These devices also emit large amounts of heat that needs to be dissipated. Hence, there exists a requirement for high-voltage insulators with good thermal conductivity for voltage isolation and efficient heat dissipation. However, these voltage insulators are generally poor conductors of heat. In the present work, an effort has been made to obtain good high-voltage insulation materials with substantial improvement in their thermal conductivity. New mixtures of composites were formed by blending varying percentages (by volumes) of aluminum nitride powders with that of neat room-temperature vulcanizing (RTV) silicone elastomer compound. In this work, a thermal conductivity test setup has been devised for the quantification of the thermal conductivity of the insulators. The thermal conductivities and high-voltage isolation capabilities of various blended composites were quantified and were compared with that of neat RTV to evaluate the relative improvement.

  5. Real-time dual-band haptic music player for mobile devices.

    PubMed

    Hwang, Inwook; Lee, Hyeseon; Choi, Seungmoon

    2013-01-01

    We introduce a novel dual-band haptic music player for real-time simultaneous vibrotactile playback with music in mobile devices. Our haptic music player features a new miniature dual-mode actuator that can produce vibrations consisting of two principal frequencies and a real-time vibration generation algorithm that can extract vibration commands from a music file for dual-band playback (bass and treble). The algorithm uses a "haptic equalizer" and provides plausible sound-to-touch modality conversion based on human perceptual data. In addition, we present a user study carried out to evaluate the subjective performance (precision, harmony, fun, and preference) of the haptic music player, in comparison with the current practice of bass-band-only vibrotactile playback via a single-frequency voice-coil actuator. The evaluation results indicated that the new dual-band playback outperforms the bass-only rendering, also providing several insights for further improvements. The developed system and experimental findings have implications for improving the multimedia experience with mobile devices.

  6. Evaluation of Intrinsic Charge Carrier Transport at Insulator-Semiconductor Interfaces Probed by a Non-Contact Microwave-Based Technique

    PubMed Central

    Honsho, Yoshihito; Miyakai, Tomoyo; Sakurai, Tsuneaki; Saeki, Akinori; Seki, Shu

    2013-01-01

    We have successfully designed the geometry of the microwave cavity and the thin metal electrode, achieving resonance of the microwave cavity with the metal-insulator-semiconductor (MIS) device structure. This very simple MIS device operates in the cavity, where charge carriers are injected quantitatively by an applied bias at the insulator-semiconductor interface. The local motion of the charge carriers was clearly probed through the applied external microwave field, also giving the quantitative responses to the injected charge carrier density and charge/discharge characteristics. By means of the present measurement system named field-induced time-resolved microwave conductivity (FI-TRMC), the pentacene thin film in the MIS device allowed the evaluation of the hole and electron mobility at the insulator-semiconductor interface of 6.3 and 0.34 cm2 V−1 s−1, respectively. This is the first report on the direct, intrinsic, non-contact measurement of charge carrier mobility at interfaces that has been fully experimentally verified. PMID:24212382

  7. Pre-market version of a commercially available hearing instrument with a tinnitus sound generator: feasibility of evaluation in a clinical trial.

    PubMed

    Sereda, Magdalena; Davies, Jeff; Hall, Deborah A

    2017-04-01

    This report considers feasibility of conducting a UK trial of combination devices for tinnitus, using data from the study which evaluated different listener programmes available within the pre-market version of Oticon Alta with Tinnitus Sound Generator. Open and closed questions addressed the following feasibility issues: (1) Participant recruitment; (2) Device acceptability; (3) Programme preferences in different self-nominated listening situations; (4) Usability; (5) Compliance; (6) Adverse events. Eight current combination hearing aid users (all males) aged between 62-72 years (mean age 67.25 years, SD = 3.8). All eight participants reported the physical aspects and noise options on the experimental device to be acceptable. Programmes with amplification and masking features were equally preferred over the basic amplification-only programme. Individual preferences for the different programme options varied widely, both across participants and across listening situations. A set of recommendations for future trials were formulated which calls for more "real world" trial design rather than tightly controlling the fitting procedure.

  8. Bio-Inspired Multi-Functional Drug Transport Design Concept and Simulations †

    PubMed Central

    Pidaparti, Ramana M.; Cartin, Charles; Su, Guoguang

    2017-01-01

    In this study, we developed a microdevice concept for drug/fluidic transport taking an inspiration from supramolecular motor found in biological cells. Specifically, idealized multi-functional design geometry (nozzle/diffuser/nozzle) was developed for (i) fluidic/particle transport; (ii) particle separation; and (iii) droplet generation. Several design simulations were conducted to demonstrate the working principles of the multi-functional device. The design simulations illustrate that the proposed design concept is feasible for multi-functionality. However, further experimentation and optimization studies are needed to fully evaluate the multifunctional device concept for multiple applications. PMID:28952516

  9. Analytical and experimental evaluation of techniques for the fabrication of thermoplastic hologram storage devices

    NASA Technical Reports Server (NTRS)

    Rogers, J. W.

    1975-01-01

    The results of an experimental investigation on recording information on thermoplastic are given. A description was given of a typical fabrication configuration, the recording sequence, and the samples which were examined. There are basically three configurations which can be used for the recording of information on thermoplastic. The most popular technique uses corona which furnishes free charge. The necessary energy for deformation is derived from a charge layer atop the thermoplastic. The other two techniques simply use a dc potential in place of the corona for deformation energy.

  10. Virtual Sensors for Advanced Controllers in Rehabilitation Robotics.

    PubMed

    Mancisidor, Aitziber; Zubizarreta, Asier; Cabanes, Itziar; Portillo, Eva; Jung, Je Hyung

    2018-03-05

    In order to properly control rehabilitation robotic devices, the measurement of interaction force and motion between patient and robot is an essential part. Usually, however, this is a complex task that requires the use of accurate sensors which increase the cost and the complexity of the robotic device. In this work, we address the development of virtual sensors that can be used as an alternative of actual force and motion sensors for the Universal Haptic Pantograph (UHP) rehabilitation robot for upper limbs training. These virtual sensors estimate the force and motion at the contact point where the patient interacts with the robot using the mathematical model of the robotic device and measurement through low cost position sensors. To demonstrate the performance of the proposed virtual sensors, they have been implemented in an advanced position/force controller of the UHP rehabilitation robot and experimentally evaluated. The experimental results reveal that the controller based on the virtual sensors has similar performance to the one using direct measurement (less than 0.005 m and 1.5 N difference in mean error). Hence, the developed virtual sensors to estimate interaction force and motion can be adopted to replace actual precise but normally high-priced sensors which are fundamental components for advanced control of rehabilitation robotic devices.

  11. Early effects of extracorporeal shock wave treatment on osteoblast-like cells: a comparative study between electromagnetic and electrohydraulic devices.

    PubMed

    Martini, Lucia; Giavaresi, Gianluca; Fini, Milena; Borsari, Veronica; Torricelli, Paola; Giardino, Roberto

    2006-11-01

    Extracorporeal shockwave therapy (ESWT) has been increasingly applied to treat orthopedic and musculoskeletal pathologies. ESWT involves mechanical perturbations that, as with other physical therapies, can result in mechanical stimuli to a large number of cells, including bone cells. The aim of this study was to evaluate the effects of shock waves on osteoblast-like cells (MG63) when using two different generators of shock waves (electrohydraulic and electromagnetic devices), in terms of cell damage, cell viability, osteogenic phenotype expression, and cytokine production. MG63 cells were suspended in 1.5 mL screw-cap cryotubes (1 x 10 cells/mL), containing phosphate buffer solution (PBS), which were maintained at 37 degrees C during all the experimental times. Two levels of energy flux density (EFD) were evaluated for each device: 0.15 to 0.18 mJ/mm2 and 0.40 mJ/mm2. Cells were then cultivated for 72 hours starting from a concentration of 1 x 10 cells/mL, and biological activity and viability were evaluated 24 and 72 hours after treatment. The results obtained demonstrate that the factors most affecting osteoblast activity involve both the device and the level of EFD selected, and they must be considered all together. The use of the electromagnetic device and a level of EFD lower than 0.40 mJ/mm2 would appear to induce fewer immediate cytodestructive effects and better stimulate subsequent proliferation and the synthetic activity of MG63.

  12. Thermal Analysis of a Disposable, Instrument-Free DNA Amplification Lab-on-a-Chip Platform.

    PubMed

    Pardy, Tamás; Rang, Toomas; Tulp, Indrek

    2018-06-04

    Novel second-generation rapid diagnostics based on nucleic acid amplification tests (NAAT) offer performance metrics on par with clinical laboratories in detecting infectious diseases at the point of care. The diagnostic assay is typically performed within a Lab-on-a-Chip (LoC) component with integrated temperature regulation. However, constraints on device dimensions, cost and power supply inherent with the device format apply to temperature regulation as well. Thermal analysis on simplified thermal models for the device can help overcome these barriers by speeding up thermal optimization. In this work, we perform experimental thermal analysis on the simplified thermal model for our instrument-free, single-use LoC NAAT platform. The system is evaluated further by finite element modelling. Steady-state as well as transient thermal analysis are performed to evaluate the performance of a self-regulating polymer resin heating element in the proposed device geometry. Reaction volumes in the target temperature range of the amplification reaction are estimated in the simulated model to assess compliance with assay requirements. Using the proposed methodology, we demonstrated our NAAT device concept capable of performing loop-mediated isothermal amplification in the 20⁻25 °C ambient temperature range with 32 min total assay time.

  13. Understanding biomaterial-tissue interface quality: combined in vitro evaluation

    PubMed Central

    Gasik, Michael

    2017-01-01

    Abstract One of the greatest challenges in the development of new medical products and devices remains in providing maximal patient safety, efficacy and suitability for the purpose. A ‘good quality’ of the tissue-implant interface is one of the most critical factors for the success of the implant integration. In this paper this challenge is being discussed from the point of view of basic stimuli combination to experimental testing. The focus is in particular on bacterial effects on tissue-implant interaction (for different materials). The demonstration of the experimental evaluation of the tissue-implant interface is for dental abutment with mucosal contact. This shows that testing of the interface quality could be the most relevant in controlled conditions, which mimic as possible the clinical applications, but consider variables being under the control of the evaluator. PMID:28970865

  14. "Johnny Poppers": a cause of serious ocular injury.

    PubMed

    MacAndie, K; Kyle, P

    1998-07-01

    The causes of blunt ocular trauma are many and diverse. We present two cases of ocular injury caused by an unusual form of weapon called a "Johnny Popper". There follows a theoretical and experimental evaluation of the velocity of the projectiles fired by this device. A Johnny Popper was constructed under expert guidance. The elastic properties of the device were measured and this allowed calculation of a theoretical exit velocity of the projectiles fired. The weapon was subsequently fired under test conditions which permitted the exit velocity of the projectiles fired to be measured directly. The theoretical velocity of the projectiles was calculated as 80 ms-1 and the experimentally measured velocity was 57 ms-1. Johnny Poppers are a previously undescribed and unique form of home made weapon. They are intended for playful mischief, but have the potential to cause serious ocular trauma.

  15. The High-efficiency LED Driver for Visible Light Communication Applications

    PubMed Central

    Gong, Cihun-Siyong Alex; Lee, Yu-Chen; Lai, Jyun-Liang; Yu, Chueh-Hao; Huang, Li Ren; Yang, Chia-Yen

    2016-01-01

    This paper presents a LED driver for VLC. The main purpose is to solve the low data rate problem used to be in switching type LED driver. The GaN power device is proposed to replace the traditional silicon power device of switching LED driver for the purpose of increasing switching frequency of converter, thereby increasing the bandwidth of data transmission. To achieve high efficiency, the diode-connected GaN power transistor is utilized to replace the traditional ultrafast recovery diode used to be in switching type LED driver. This work has been experimentally evaluated on 350-mA output current. The results demonstrate that it supports the data of PWM dimming level encoded in the PPM scheme for VLC application. The experimental results also show that system’s efficiency of 80.8% can be achieved at 1-Mb/s data rate. PMID:27498921

  16. Using smartphones and tablet PCs for β--spectroscopy in an educational experimental setup

    NASA Astrophysics Data System (ADS)

    Gröber, Sebastian; Molz, Alexander; Kuhn, Jochen

    2014-11-01

    A magnetic spectrometer is used to gather the β--spectrum of 90 Sr /Y with a focus on two aspects. (1) The intensity of β--radiation is measured by the camera sensor module of a tablet PC together with the RadioactivityCounter app and by a Geiger-Müller tube. We evaluate the quality of mobile devices as radioactive radiation detectors by using polyenergetic β--radiation as an example and by comparing the spectra measured with the two detector types. (2) For educational purposes we implement a simple experimental setup, which consists of separate devices for measuring the electron’s kinetic energy and intensity, which are available in laboratories in educational settings. Comparison of the measured β--spectra published in the literature should encourage students to think about the energy resolution power of the β--spectrometer. Theoretical considerations show the low, yet sufficient energy resolution power of this spectrometer, especially for low energy levels.

  17. Experimental evaluation of a system for human life detection under debris

    NASA Astrophysics Data System (ADS)

    Joju, Reshma; Konica, Pimplapure Ramya T.; Alex, Zachariah C.

    2017-11-01

    It is difficult to for the human beings to be found under debris or behind the walls in case of military applications. Due to which several rescue techniques such as robotic systems, optical devices, and acoustic devices were used. But if victim was unconscious then these rescue system failed. We conducted an experimental analysis on whether the microwaves could detect heart beat and breathing signals of human beings trapped under collapsed debris. For our analysis we used RADAR based on by Doppler shift effect. We calculated the minimum speed that the RADAR could detect. We checked the frequency variation by placing the RADAR at a fixed position and placing the object in motion at different distances. We checked the frequency variation by using objects of different materials as debris behind which the motion was made. The graphs of different analysis were plotted.

  18. Road Nail: Experimental Solar Powered Intelligent Road Marking System

    NASA Astrophysics Data System (ADS)

    Samardžija, Dragan; Teslić, Nikola; Todorović, Branislav M.; Kovač, Erne; Isailović, Đorđe; Miladinović, Bojan

    2012-03-01

    Driving in low visibility conditions (night time, fog or heavy precipitation) is particularly challenging task with an increased probability of traffic accidents and possible injuries. Road Nail is a solar powered intelligent road marking system of wirelessly networked signaling devices that improve driver safety in low visibility conditions along hazardous roadways. Nails or signaling devices are autonomous nodes with capability to accumulate energy, exchange wireless messages, detect approaching vehicles and emit signalization light. We have built an experimental test-bed that consists of 20 nodes and a cellular gateway. Implementation details of the above system, including extensive measurements and performance evaluations in realistic field deployments are presented. A novel distributed network topology discovery scheme is proposed which integrates both sensor and wireless communication aspects, where nodes act autonomously. Finally, integration of the Road Nail system with the cellular network and the Internet is described.

  19. Evaluation and improvement of the efficiency of the Seidel humeral nail by numerical-experimental analysis of the bone-implant contact.

    PubMed

    Giudice, Fabio; La Rosa, Guido; Russo, Tullio; Varsalona, Roberto

    2006-09-01

    Seidel intramedullary humeral nail is locked distally by a spreading device and proximally by transverse cross locking screws. The main problems found in its use are: the loosening of the distal anchorage, even after X-ray verification of the correct expansion of the device; the formation of distal fractures, occurring even 1 month after the operation; the system's low stability. The problems noted can be ascribed to the behaviour of the spreading device for distal fixing. The present study, therefore, was directed at analysing the contact between the spreading mechanism and the medullary canal in relation to the geometric parameters of the mechanism itself. The main objective was to define the correct regulation of the expansion in the operating theatre, and to delimit the more appropriate conditions of use, allowing the surgeon to evaluate the suitability of this particular device for the type of fracture under treatment. Numerical and experimental techniques were used to perform an analysis of the implant behaviour. This investigation, referred to immediate post-operative condition, allowed to evaluate the stability to traction of the system, to define the typology and properties of the bone-implant contact zone and to quantify the stresses produced, all as a function of the parameter on which the surgeon intervenes in the operating theatre: the number of turns used to tighten the spreading screw. The results obtained confirm and explain the disadvantages associated with the distal expansion system: the bone-implant contact turns out to be inefficient, as revealed by the distribution of the pressure on the inner wall of the medullary canal. On the basis of the results, it is possible to define the optimal conditions of use of the nail, and to formulate a simple solution for the improvement of its performance.

  20. Design, characterization, and experimental use of the second generation MEMS acoustic emission device

    NASA Astrophysics Data System (ADS)

    Ozevin, Didem; Greve, David W.; Oppenheim, Irving J.; Pessiki, Stephen

    2005-05-01

    We describe the design, fabrication, testing and application (in structural experiments) of our 2004 (second generation) MEMS device, designed for acoustic emission sensing based upon experiments with our 2002 (first generation) device. Both devices feature a suite of resonant-type transducers in the frequency range between 100 kHz and 1 MHz. The 2002 device was designed to operate in an evacuated housing because of high squeeze film damping, as confirmed in our earlier experiments. In additional studies involving the 2002 device, experimental simulation of acoustic emissions in a steel plate, using pencil lead break or ball impact loading, showed that the transducers in the frequency range of 100 kHz-500 kHz presented clearer output signals than the transducers with frequencies higher than 500 kHz. Using the knowledge gained from the 2002 device, we designed and fabricated our second generation device in 2004 using the multi-user polysilicon surface micromachining (MUMPs) process. The 2004 device has 7 independent capacitive type transducers, compared to 18 independent transducers in the 2002 device, including 6 piston type transducers in the frequency range of 100 kHz to 500 kHz and 1 piston type transducer at 1 MHz to capture high frequency information. Piston type transducers developed in our research have two uncoupled modes so that twofold information can be acquired from a single transducer. In addition, the piston shape helps to reduce residual stress effect of surface micromachining process. The center to center distance between etch holes in the vibrating plate was reduced from 30 μm to 13 μm, in order to reduce squeeze film damping. As a result, the Q factor under atmospheric pressure for the 100 kHz transducer was increased to 2.37 from 0.18, and therefore the vacuum housing has been eliminated from the 2004 device. Sensitivities of transducers were also increased, by enlarging transducer area, in order to capture significant small amplitude acoustic emission events. The average individual transducer area in the 2004 device was increased to 6.97 mm2 as compared to 2.51 mm2 in the 2002 device. In this paper, we report the new experimental results on the characterization of the 2004 device and compare them with analytical results. We show improvements in sensitivity as measured by capacitance and as measured by pencil lead break experiments. Improvement in damping is also evaluated by admittance measurement in atmosphere. Pencil lead break experiments also show that transducers can operate in atmospheric pressure. Finally, we apply the device to acoustic emission experiments on crack propagation in a steel beam specimen, precracked in fatigue, in a four-point bending test.

  1. Proton Single Event Effects (SEE) Testing of the Myrinet Crossbar Switch and Network Interface Card

    NASA Technical Reports Server (NTRS)

    Howard, James W., Jr.; LaBel, Kenneth A.; Carts, Martin A.; Stattel, Ronald; Irwin, Timothy L.; Day, John H. (Technical Monitor)

    2002-01-01

    As part of the Remote Exploration and Experimentation Project (REE), work was performed to do a proton SEE (Single Event Effect) evaluation of the Myricom network protocol system (Myrinet). This testing included the evaluation of the Myrinet crossbar switch and the Network Interface Card (NIC). To this end, two crossbar switch devices and five components in the NIC were exposed to the proton beam at the University of California at Davis Crocker Nuclear Laboratory (CNL).

  2. HuMOVE: a low-invasive wearable monitoring platform in sexual medicine.

    PubMed

    Ciuti, Gastone; Nardi, Matteo; Valdastri, Pietro; Menciassi, Arianna; Basile Fasolo, Ciro; Dario, Paolo

    2014-10-01

    To investigate an accelerometer-based wearable system, named Human Movement (HuMOVE) platform, designed to enable quantitative and continuous measurement of sexual performance with minimal invasiveness and inconvenience for users. Design, implementation, and development of HuMOVE, a wearable platform equipped with an accelerometer sensor for monitoring inertial parameters for sexual performance assessment and diagnosis, were performed. The system enables quantitative measurement of movement parameters during sexual intercourse, meeting the requirements of wearability, data storage, sampling rate, and interfacing methods, which are fundamental for human sexual intercourse performance analysis. HuMOVE was validated through characterization using a controlled experimental test bench and evaluated in a human model during simulated sexual intercourse conditions. HuMOVE demonstrated to be a robust and quantitative monitoring platform and a reliable candidate for sexual performance evaluation and diagnosis. Characterization analysis on the controlled experimental test bench demonstrated an accurate correlation between the HuMOVE system and data from a reference displacement sensor. Experimental tests in the human model during simulated intercourse conditions confirmed the accuracy of the sexual performance evaluation platform and the effectiveness of the selected and derived parameters. The obtained outcomes also established the project expectations in terms of usability and comfort, evidenced by the questionnaires that highlighted the low invasiveness and acceptance of the device. To the best of our knowledge, HuMOVE platform is the first device for human sexual performance analysis compatible with sexual intercourse; the system has the potential to be a helpful tool for physicians to accurately classify sexual disorders, such as premature or delayed ejaculation. Copyright © 2014 Elsevier Inc. All rights reserved.

  3. An experimental abdominal pressure measurement device for child ATDs.

    DOT National Transportation Integrated Search

    1995-12-01

    An experimental device to measure the abdominal pressure in child-size Anthropomorphic Test Dummies (ATDs) during dynamic tests was developed. A description is provided of the two ATDs in which the device was installed, the CRABI six-month-old and th...

  4. Comparison of Detector Technologies for CAPS

    NASA Technical Reports Server (NTRS)

    Stockum, Jana L.

    2005-01-01

    In this paper, several different detectors are examined for use in a Comet/Asteroid Protection System (CAPS), a conceptual study for a possible future space-based system. Each detector will be examined for its future (25 years or more in the future) ability to find and track near-Earth Objects (NEOs) from a space-based detection platform. Within the CAPS study are several teams of people who each focus on different aspects of the system concept. This study s focus is on detection devices. In particular, evaluations on the following devices have been made: charge-coupled devices (CCDs), charge-injected devices (CIDs), superconducting tunneling junctions (STJs), and transition edge sensors (TESs). These devices can be separated into two main categories; the first category includes detectors that are currently being widely utilized, such as CCDs and CIDs. The second category includes experimental detectors, such as STJs and TESs. After the discussion of the detectors themselves, there will be a section devoted to the explicit use of these detectors with CAPS.

  5. Direct current force sensing device based on compressive spring, permanent magnet, and coil-wound magnetostrictive/piezoelectric laminate.

    PubMed

    Leung, Chung Ming; Or, Siu Wing; Ho, S L

    2013-12-01

    A force sensing device capable of sensing dc (or static) compressive forces is developed based on a NAS106N stainless steel compressive spring, a sintered NdFeB permanent magnet, and a coil-wound Tb(0.3)Dy(0.7)Fe(1.92)/Pb(Zr, Ti)O3 magnetostrictive∕piezoelectric laminate. The dc compressive force sensing in the device is evaluated theoretically and experimentally and is found to originate from a unique force-induced, position-dependent, current-driven dc magnetoelectric effect. The sensitivity of the device can be increased by increasing the spring constant of the compressive spring, the size of the permanent magnet, and/or the driving current for the coil-wound laminate. Devices of low-force (20 N) and high-force (200 N) types, showing high output voltages of 262 and 128 mV peak, respectively, are demonstrated at a low driving current of 100 mA peak by using different combinations of compressive spring and permanent magnet.

  6. Integrative Multi-Spectral Sensor Device for Far-Infrared and Visible Light Fusion

    NASA Astrophysics Data System (ADS)

    Qiao, Tiezhu; Chen, Lulu; Pang, Yusong; Yan, Gaowei

    2018-06-01

    Infrared and visible light image fusion technology is a hot spot in the research of multi-sensor fusion technology in recent years. Existing infrared and visible light fusion technologies need to register before fusion because of using two cameras. However, the application effect of the registration technology has yet to be improved. Hence, a novel integrative multi-spectral sensor device is proposed for infrared and visible light fusion, and by using the beam splitter prism, the coaxial light incident from the same lens is projected to the infrared charge coupled device (CCD) and visible light CCD, respectively. In this paper, the imaging mechanism of the proposed sensor device is studied with the process of the signals acquisition and fusion. The simulation experiment, which involves the entire process of the optic system, signal acquisition, and signal fusion, is constructed based on imaging effect model. Additionally, the quality evaluation index is adopted to analyze the simulation result. The experimental results demonstrate that the proposed sensor device is effective and feasible.

  7. Polarization-maintaining reflection-mode THz time-domain spectroscopy of a polyimide based ultra-thin narrow-band metamaterial absorber.

    PubMed

    Astorino, Maria Denise; Fastampa, Renato; Frezza, Fabrizio; Maiolo, Luca; Marrani, Marco; Missori, Mauro; Muzi, Marco; Tedeschi, Nicola; Veroli, Andrea

    2018-01-31

    This paper reports the design, the microfabrication and the experimental characterization of an ultra-thin narrow-band metamaterial absorber at terahertz frequencies. The metamaterial device is composed of a highly flexible polyimide spacer included between a top electric ring resonator with a four-fold rotational symmetry and a bottom ground plane that avoids misalignment problems. Its performance has been experimentally demonstrated by a custom polarization-maintaining reflection-mode terahertz time-domain spectroscopy system properly designed in order to reach a collimated configuration of the terahertz beam. The dependence of the spectral characteristics of this metamaterial absorber has been evaluated on the azimuthal angle under oblique incidence. The obtained absorbance levels are comprised between 67% and 74% at 1.092 THz and the polarization insensitivity has been verified in transverse electric polarization. This offers potential prospects in terahertz imaging, in terahertz stealth technology, in substance identification, and in non-planar applications. The proposed compact experimental set-up can be applied to investigate arbitrary polarization-sensitive terahertz devices under oblique incidence, allowing for a wide reproducibility of the measurements.

  8. A new exposure model to evaluate smoked illicit drugs in rodents: A study of crack cocaine.

    PubMed

    Hueza, Isis M; Ponce, Fernando; Garcia, Raphael C T; Marcourakis, Tânia; Yonamine, Maurício; Mantovani, Cínthia de C; Kirsten, Thiago B

    2016-01-01

    The use of smoked illicit drugs has spread dramatically, but few studies use proper devices to expose animals to inhalational abused drugs despite the availability of numerous smoking devices that mimic tobacco exposure in rodents. Therefore, the present study developed an inexpensive device to easily expose laboratory animals to smoked drugs. We used crack cocaine as the drug of abuse, and the cocaine plasma levels and the behaviors of animals intoxicated with the crack cocaine were evaluated to prove inhaled drug absorption and systemic activity. We developed an acrylic device with two chambers that were interconnected and separated by a hatch. Three doses of crack (100, 250, or 500 mg), which contained 63.7% cocaine, were burned in a pipe, and the rats were exposed to the smoke for 5 or 10 min (n=5/amount/period). Exposure to the 250-mg dose for 10 min achieved cocaine plasma levels that were similar to those of users (170 ng/mL). Behavioral evaluations were also performed to validate the methodology. Rats (n=10/group) for these evaluations were exposed to 250 mg of crack cocaine or air for 10 min, twice daily, for 28 consecutive days. Open-field evaluations were performed at three different periods throughout the experimental design. Exposed animals exhibited transient anorexia, increased motor activity, and shorter stays in central areas of the open field, which suggests reduced anxiety. Therefore, the developed model effectively exposed animals to crack cocaine, and this model may be useful for the investigation of other inhalational abused drugs. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. [Validation of a new hand-carried ultrasound device equipped with directional color power Doppler and continuous wave Doppler].

    PubMed

    Kawai, Junichi; Tanabe, Kazuaki; Matsuzaki, Masashi; Yamaguchi, Kazuto; Yagi, Toshikazu; Fujii, Yoko; Konda, Toshiko; Ui, Kazuyo; Sumida, Toshiaki; Okada, Midori; Tani, Tomoko; Morioka, Shigefumi

    2003-10-01

    This study evaluated the accuracy of the directional color power Doppler (DCPD) and continuous wave Doppler (CWD) methods incorporated in the new hand-carried SonoSite 180PLUS ultrasound device. The hand-held ultrasound system with 2.5 MHz transducer and SONOS 5500 was used as a standard ultrasound system with a 2 to 4 MHz wideband transducer. The experimental study used a Doppler wire phantom to evaluate the influence of target wire speed and angle of transducer on DCPD imaging. The clinical study included 48 consecutive patients. DCPD assessment of valvular regurgitation measured the distances of DCPD signals of mitral, aortic and tricuspid valve regurgitation using the apical four-chamber view for comparison with standard echocardiography. CWD assessment measured the peak velocities of the aortic flow and tricuspid valve regurgitant flow for comparison with standard echocardiography. In the experimental study, DCPD signals were not influenced by target wire speed changes and transducer incident angles. In the clinical study, agreements for mitral, aortic and tricuspid regurgitation between the two methods were 89.6%, 81.8% and 78.7%, respectively. The distances of DCPD valve regurgitant signals by the hand-carried ultrasound device showed good correlation (mitral regurgitation: y = 0.84x + 0.55; r = 0.93, aortic regurgitation: y = 0.95x + 0.27; r = 0.94, tricuspid regurgitation: y = 0.86x + 0.61; r = 0.90) with those by standard echocardiography. Evaluation of CWD velocity measurements showed good agreement for the lower flow velocities (< 2.0 m/sec). However, underestimation occurred for the high flow velocities (> 2.0 m/sec) compared with those by standard echocardiography (aortic flow: y = 0.80x + 0.11; r = 0.95, tricuspid regurgitation: y = 1.00x - 0.23; r = 0.90). The new hand-carried ultrasound device (SonoSite 180PLUS equipped with DCPD and CWD) is clinically useful for evaluating valvular regurgitations and flow velocities. Further studies are needed to determine the mechanism of the underestimation of high flow velocities by CWD.

  10. SHEEP AS AN EXPERIMENTAL MODEL FOR BIOMATERIAL IMPLANT EVALUATION

    PubMed Central

    SARTORETTO, SUELEN CRISTINA; UZEDA, MARCELO JOSÉ; MIGUEL, FÚLVIO BORGES; NASCIMENTO, JHONATHAN RAPHAELL; ASCOLI, FABIO; CALASANS-MAIA, MÔNICA DIUANA

    2016-01-01

    ABSTRACT Objective: Based on a literature review and on our own experience, this study proposes sheep as an experimental model to evaluate the bioactive capacity of bone substitute biomaterials, dental implant systems and orthopedics devices. The literature review covered relevant databases available on the Internet from 1990 until to date, and was supplemented by our own experience. Methods: For its resemblance in size and weight to humans, sheep are quite suitable for use as an experimental model. However, information about their utility as an experimental model is limited. The different stages involving sheep experiments were discussed, including the care during breeding and maintenance of the animals obtaining specimens for laboratory processing, and highlighting the unnecessary euthanasia of animals at the end of study, in accordance to the guidelines of the 3Rs Program. Results: All experiments have been completed without any complications regarding the animals and allowed us to evaluate hypotheses and explain their mechanisms. Conclusion: The sheep is an excellent animal model for evaluation of biomaterial for bone regeneration and dental implant osseointegration. From an ethical point of view, one sheep allows for up to 12 implants per animal, permitting to keep them alive at the end of the experiments. Level of Evidence II, Retrospective Study. PMID:28149193

  11. New alternatives for laser vaporization of the prostate: experimental evaluation of a 980-, 1,318- and 1,470-nm diode laser device.

    PubMed

    Wezel, Felix; Wendt-Nordahl, Gunnar; Huck, Nina; Bach, Thorsten; Weiss, Christel; Michel, Maurice Stephan; Häcker, Axel

    2010-04-01

    Several diode laser systems were introduced in recent years for the minimal-invasive surgical therapy of benign prostate enlargement. We investigated the ablation capacities, hemostatic properties and extend of tissue necrosis of different diode lasers at wavelengths of 980, 1,318 and 1,470 nm and compared the results to the 120 W GreenLight HPS laser. The laser devices were evaluated in an ex vivo model using isolated porcine kidneys. The weight difference of the porcine kidneys after 10 min of laser vaporization defined the amount of ablated tissue. Blood loss was measured in blood-perfused kidneys following laser vaporization. Histological examination was performed to assess the tissue effects. The side-firing 980 and 1,470 nm diode lasers displayed similar ablative capacities compared to the GreenLight HPS laser (n.s.). The 1,318-nm laser, equipped with a bare-ended fiber, reached a higher ablation rate compared to the other laser devices (each P < 0.05). A calculated 'output power efficiency per watt' revealed that the 1,318-nm laser with a bare-ended fiber reached the highest rate compared to the side-firing devices (each P < 0.0001). All three diode lasers showed superior hemostatic properties compared to the GreenLight HPS laser (each P < 0.01). The extend of morphological tissue necrosis was 4.62 mm (1,318 nm), 1.30 mm (1,470 nm), 4.18 mm (980 nm) and 0.84 mm (GreenLight HPS laser), respectively. The diode lasers offered similar ablative capacities and improved hemostatic properties compared to the 120 W GreenLight HPS laser in this experimental ex vivo setting. The higher tissue penetration of the diode lasers compared to the GreenLight HPS laser may explain improved hemostasis.

  12. iHandRehab: an interactive hand exoskeleton for active and passive rehabilitation.

    PubMed

    Li, Jiting; Zheng, Ruoyin; Zhang, Yuru; Yao, Jianchu

    2011-01-01

    This paper presents an interactive exoskeleton device for hand rehabilitation, iHandRehab, which aims to satisfy the essential requirements for both active and passive rehabilitation motions. iHandRehab is comprised of exoskeletons for the thumb and index finger. These exoskeletons are driven by distant actuation modules through a cable/sheath transmission mechanism. The exoskeleton for each finger has 4 degrees of freedom (DOF), providing independent control for all finger joints. The joint motion is accomplished by a parallelogram mechanism so that the joints of the device and their corresponding finger joints have the same angular displacement when they rotate. Thanks to this design, the joint angles can be measured by sensors real time and high level motion control is therefore made very simple without the need of complicated kinematics. The paper also discusses important issues when the device is used by different patients, including its adjustable joint range of motion (ROM) and adjustable range of phalanx length (ROPL). Experimentally collected data show that the achieved ROM is close to that of a healthy hand and the ROPL covers the size of a typical hand, satisfying the size need of regular hand rehabilitation. In order to evaluate the performance when it works as a haptic device in active mode, the equivalent moment of inertia (MOI) of the device is calculated. The results prove that the device has low inertia which is critical in order to obtain good backdrivability. Experimental analysis shows that the influence of friction accounts for a large portion of the driving torque and warrants future investigation. © 2011 IEEE

  13. Experimental and analytical parametric study of single-crystal unimorph beams for vibration energy harvesting.

    PubMed

    Karami, M Amin; Bilgen, Onur; Inman, Daniel J; Friswell, Michael I

    2011-07-01

    This research presents an experimental and theoretical energy harvesting characterization of beam-like, uniform cross-section, unimorph structures employing single-crystal piezoelectrics. Different piezoelectric materials, substrates, and configurations are examined to identify the best design configuration for lightweight energy harvesting devices for low-power applications. Three types of piezoelectrics (singlecrystal PMN-PZT, polycrystalline PZT-5A, and PZT-5H-type monolithic ceramics) are evaluated in a unimorph cantilevered beam configuration. The devices have been excited by harmonic base acceleration. All of the experimental characteristics have been used to validate an exact electromechanical model of the harvester. The study shows the optimum choice of substrate material for single-crystal piezoelectric energy harvesting. Comparison of energy scavengers with stainless steel substrates reveals that single-crystal harvesters produce superior power compared with polycrystalline devices. To further optimize the power harvesting, we study the relation between the thickness of the substrate and the power output for different substrate materials. The relation between power and substrate thickness profoundly varies among different substrate materials. The variation is understood by examining the change of mechanical transmissibility and the variations of the coupling figure of merit of the harvesters with thickness ratio. The investigation identifies the optimal thickness of the substrate for different substrate materials. The study also shows that the densities of the substrates and their mechanical damping coefficients have significant effects on the power output.

  14. Verification technology of remote sensing camera satellite imaging simulation based on ray tracing

    NASA Astrophysics Data System (ADS)

    Gu, Qiongqiong; Chen, Xiaomei; Yang, Deyun

    2017-08-01

    Remote sensing satellite camera imaging simulation technology is broadly used to evaluate the satellite imaging quality and to test the data application system. But the simulation precision is hard to examine. In this paper, we propose an experimental simulation verification method, which is based on the test parameter variation comparison. According to the simulation model based on ray-tracing, the experiment is to verify the model precision by changing the types of devices, which are corresponding the parameters of the model. The experimental results show that the similarity between the imaging model based on ray tracing and the experimental image is 91.4%, which can simulate the remote sensing satellite imaging system very well.

  15. The experimental results of AMTEC and a study of its terrestrial applications in IEE of China

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ni, Q.; Tong, J.; Kan, Y.

    1997-12-31

    The R and D activities in the field of AMTEC research at The Institute of Electrical Engineering, Chinese Academy of Sciences are introduced. The outline of experimental facility with a single tube cell is described. The experimental results so far are reported followed by an analysis of electrical characteristic, in particular, an evaluation of characteristic of BASE/porous electrode interface with the effective sheet resistivity and the electrode efficiency. The approaches for improving device performance are discussed. The terrestrial applications of AMTEC in China are considered as an alternative of conventional diesel-generators. The possibility of AMTEC power supply for some separatemore » sites is predicted.« less

  16. Recent Developments in Home Sleep-Monitoring Devices

    PubMed Central

    Kelly, Jessica M.; Strecker, Robert E.; Bianchi, Matt T.

    2012-01-01

    Improving our understanding of sleep physiology and pathophysiology is an important goal for both medical and general wellness reasons. Although the gold standard for assessing sleep remains the laboratory polysomnogram, there is an increasing interest in portable monitoring devices that provide the opportunity for assessing sleep in real-world environments such as the home. Portable devices allow repeated measurements, evaluation of temporal patterns, and self-experimentation. We review recent developments in devices designed to monitor sleep-wake activity, as well as monitors designed for other purposes that could in principle be applied in the field of sleep (such as cardiac or respiratory sensing). As the body of supporting validation data grows, these devices hold promise for a variety of health and wellness goals. From a clinical and research standpoint, the capacity to obtain longitudinal sleep-wake data may improve disease phenotyping, individualized treatment decisions, and individualized health optimization. From a wellness standpoint, commercially available devices may allow individuals to track their own sleep with the goal of finding patterns and correlations with modifiable behaviors such as exercise, diet, and sleep aids. PMID:23097718

  17. Power Consumption Analysis of Operating Systems for Wireless Sensor Networks

    PubMed Central

    Lajara, Rafael; Pelegrí-Sebastiá, José; Perez Solano, Juan J.

    2010-01-01

    In this paper four wireless sensor network operating systems are compared in terms of power consumption. The analysis takes into account the most common operating systems—TinyOS v1.0, TinyOS v2.0, Mantis and Contiki—running on Tmote Sky and MICAz devices. With the objective of ensuring a fair evaluation, a benchmark composed of four applications has been developed, covering the most typical tasks that a Wireless Sensor Network performs. The results show the instant and average current consumption of the devices during the execution of these applications. The experimental measurements provide a good insight into the power mode in which the device components are running at every moment, and they can be used to compare the performance of different operating systems executing the same tasks. PMID:22219688

  18. Power consumption analysis of operating systems for wireless sensor networks.

    PubMed

    Lajara, Rafael; Pelegrí-Sebastiá, José; Perez Solano, Juan J

    2010-01-01

    In this paper four wireless sensor network operating systems are compared in terms of power consumption. The analysis takes into account the most common operating systems--TinyOS v1.0, TinyOS v2.0, Mantis and Contiki--running on Tmote Sky and MICAz devices. With the objective of ensuring a fair evaluation, a benchmark composed of four applications has been developed, covering the most typical tasks that a Wireless Sensor Network performs. The results show the instant and average current consumption of the devices during the execution of these applications. The experimental measurements provide a good insight into the power mode in which the device components are running at every moment, and they can be used to compare the performance of different operating systems executing the same tasks.

  19. Local bipolar-transistor gain measurement for VLSI devices

    NASA Astrophysics Data System (ADS)

    Bonnaud, O.; Chante, J. P.

    1981-08-01

    A method is proposed for measuring the gain of a bipolar transistor region as small as possible. The measurement then allows the evaluation particularly of the effect of the emitter-base junction edge and the technology-process influence of VLSI-technology devices. The technique consists in the generation of charge carriers in the transistor base layer by a focused laser beam in order to bias the device in as small a region as possible. To reduce the size of the conducting area, a transversal reverse base current is forced through the base layer resistance in order to pinch in the emitter current in the illuminated region. Transistor gain is deduced from small signal measurements. A model associated with this technique is developed, and this is in agreement with the first experimental results.

  20. Ignition patterns & prescribed fire behavior in southern pine stands

    Treesearch

    Ragnar W. Johansen

    1987-01-01

    As an aid to forest managers who use or contemplate using aerial ignition techniques in their prescribed burning programs, a study was designed to evaluate the magnitude of the differences that could occur depending on whether lines of fire were used (ignited by a helitorch) or a spot-fire technique was used (ignited by aerial ignition devices). Six experimental fires...

  1. Teleconferencing in Education. Evaluation of the Charlton Pilot Project (or, How the Teachers Blew Up the Charlton Bridge).

    ERIC Educational Resources Information Center

    Conboy, Ian

    The Charlton pilot project was one of a number of trials undertaken throughout Australia to bring educational resources to isolated children. In this project, Telecom Australia provided seven small Victorian Higher School Certificate (H.S.C.) schools with two first prototype experimental devices: firstly, a small group terminal and secondly,…

  2. Demonstration of Hydrostatic Paradox with Plastic Bottles and LabQuest Vernier

    ERIC Educational Resources Information Center

    Kodejška, Cenek

    2018-01-01

    This work focuses on the experimental demonstration of the hydrostatic paradox using simple tools in the form of plastic bottles and plastic syringes with a thread. For the evaluation of the results obtained the data logger Lab Quest Vernier was used. The construction of the device is presented in the first part of this paper. The second part…

  3. A new device to estimate abundance of moist-soil plant seeds

    USGS Publications Warehouse

    Penny, E.J.; Kaminski, R.M.; Reinecke, K.J.

    2006-01-01

    Methods to sample the abundance of moist-soil seeds efficiently and accurately are critical for evaluating management practices and determining food availability. We adapted a portable, gasoline-powered vacuum to estimate abundance of seeds on the surface of a moist-soil wetland in east-central Mississippi and evaluated the sampler by simulating conditions that researchers and managers may experience when sampling moist-soil areas for seeds. We measured the percent recovery of known masses of seeds by the vacuum sampler in relation to 4 experimentally controlled factors (i.e., seed-size class, sample mass, soil moisture class, and vacuum time) with 2-4 levels per factor. We also measured processing time of samples in the laboratory. Across all experimental factors, seed recovery averaged 88.4% and varied little (CV = 0.68%, n = 474). Overall, mean time to process a sample was 30.3 ? 2.5 min (SE, n = 417). Our estimate of seed recovery rate (88%) may be used to adjust estimates for incomplete seed recovery, or project-specific correction factors may be developed by investigators. Our device was effective for estimating surface abundance of moist-soil plant seeds after dehiscence and before habitats were flooded.

  4. A methodology to emulate and evaluate a productive virtual workstation

    NASA Technical Reports Server (NTRS)

    Krubsack, David; Haberman, David

    1992-01-01

    The Advanced Display and Computer Augmented Control (ADCACS) Program at ACT is sponsored by NASA Ames to investigate the broad field of technologies which must be combined to design a 'virtual' workstation for the Space Station Freedom. This program is progressing in several areas and resulted in the definition of requirements for a workstation. A unique combination of technologies at the ACT Laboratory have been networked to effectively create an experimental environment. This experimental environment allows the integration of nonconventional input devices with a high power graphics engine within the framework of an expert system shell which coordinates the heterogeneous inputs with the 'virtual' presentation. The flexibility of the workstation is evolved as experiments are designed and conducted to evaluate the condition descriptions and rule sets of the expert system shell and its effectiveness in driving the graphics engine. Workstation productivity has been defined by the achievable performance in the emulator of the calibrated 'sensitivity' of input devices, the graphics presentation, the possible optical enhancements to achieve a wide field of view color image and the flexibility of conditional descriptions in the expert system shell in adapting to prototype problems.

  5. CFD Study of NACA 0018 Airfoil with Flow Control

    NASA Technical Reports Server (NTRS)

    Eggert, Christopher A.; Rumsey, Christopher L.

    2017-01-01

    The abilities of two different Reynolds-Averaged Navier-Stokes codes to predict the effects of an active flow control device are evaluated. The flow control device consists of a blowing slot located on the upper surface of an NACA 0018 airfoil, near the leading edge. A second blowing slot present on the airfoil near mid-chord is not evaluated here. Experimental results from a wind tunnel test show that a slot blowing with high momentum coefficient will increase the lift of the airfoil (compared to no blowing) and delay flow separation. A slot with low momentum coefficient will decrease the lift and induce separation even at low angles of attack. Two codes, CFL3D and FUN3D, are used in two-dimensional computations along with several different turbulence models. Two of these produced reasonable results for this flow, when run fully turbulent. A more advanced transition model failed to predict reasonable results, but warrants further study using different inputs. Including inviscid upper and lower tunnel walls in the simulations was found to be important in obtaining pressure distributions and lift coefficients that best matched experimental data. A limited number of three-dimensional computations were also performed.

  6. Experimental and numeric investigation of Impella pumps as cavopulmonary assistance for a failing Fontan.

    PubMed

    Haggerty, Christopher M; Fynn-Thompson, Francis; McElhinney, Doff B; Valente, Anne Marie; Saikrishnan, Neelakantan; Del Nido, Pedro J; Yoganathan, Ajit P

    2012-09-01

    This study sought to evaluate the performance of microaxial ventricular assist devices for the purposes of supporting failing Fontan physiology by decreasing central venous pressure. Three Abiomed Impella pumps (Abiomed, Inc, Danvers, Mass) were evaluated in a mock circulatory system of the Fontan circuit. The local response of pressures and flows to pump function was assessed as a function of pump speed and pulmonary vascular resistance at a high baseline central venous pressure. For one device, subsequent modeling studies were conducted using a lumped parameter model of the single ventricle circuit. The left ventricular devices (Impella 2.5, 5.0) were shown to be suboptimal as single device solutions for cavopulmonary support. The small area of these devices relative to vessel diameter led to significant flow recirculation without an obstructive separator in place. Furthermore, downstream pressure augmentation adversely affected the pressure in the superior vena cava. The use of 2 devices would be mandatory for successful support. The right-sided device (Impella RP), whose outflow was positioned in the left pulmonary artery, demonstrated decreased flow recirculation and did not impede superior caval venous flow. Although static pressure is still required to drive flow through the opposite lung, numeric modeling demonstrated the potential for modest but significant improvements in lowering the central venous pressure (2-8 mm Hg). Left-sided microaxial pumps are not well suited for cavopulmonary support because of severe flow recirculation and the need for multiple devices. The right-ventricular Impella device provides improved performance by directing flow into the pulmonary artery, resulting in modest decreases in central venous pressure. Copyright © 2012 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  7. Design and Characterization of an Exoskeleton for Perturbing the Knee During Gait.

    PubMed

    Tucker, Michael R; Shirota, Camila; Lambercy, Olivier; Sulzer, James S; Gassert, Roger

    2017-10-01

    An improved understanding of mechanical impedance modulation in human joints would provide insights about the neuromechanics underlying functional movements. Experimental estimation of impedance requires specialized tools with highly reproducible perturbation dynamics and reliable measurement capabilities. This paper presents the design and mechanical characterization of the ETH Knee Perturbator: an actuated exoskeleton for perturbing the knee during gait. A novel wearable perturbation device was developed based on specific experimental objectives. Bench-top tests validated the device's torque limiting capability and characterized the time delays of the on-board clutch. Further tests demonstrated the device's ability to perform system identification on passive loads with static initial conditions. Finally, the ability of the device to consistently perturb human gait was evaluated through a pilot study on three unimpaired subjects. The ETH Knee Perturbator is capable of identifying mass-spring systems within 15% accuracy, accounting for over 95% of the variance in the observed torque in 10 out of 16 cases. Five-degree extension and flexion perturbations were executed on human subjects with an onset timing precision of 2.52% of swing phase duration and a rise time of 36.5 ms. The ETH Knee Perturbator can deliver safe, precisely timed, and controlled perturbations, which is a prerequisite for the estimation of knee joint impedance during gait. Tools such as this can enhance models of neuromuscular control, which may improve rehabilitative outcomes following impairments affecting gait and advance the design and control of assistive devices.

  8. Efficient Execution of Microscopy Image Analysis on CPU, GPU, and MIC Equipped Cluster Systems.

    PubMed

    Andrade, G; Ferreira, R; Teodoro, George; Rocha, Leonardo; Saltz, Joel H; Kurc, Tahsin

    2014-10-01

    High performance computing is experiencing a major paradigm shift with the introduction of accelerators, such as graphics processing units (GPUs) and Intel Xeon Phi (MIC). These processors have made available a tremendous computing power at low cost, and are transforming machines into hybrid systems equipped with CPUs and accelerators. Although these systems can deliver a very high peak performance, making full use of its resources in real-world applications is a complex problem. Most current applications deployed to these machines are still being executed in a single processor, leaving other devices underutilized. In this paper we explore a scenario in which applications are composed of hierarchical data flow tasks which are allocated to nodes of a distributed memory machine in coarse-grain, but each of them may be composed of several finer-grain tasks which can be allocated to different devices within the node. We propose and implement novel performance aware scheduling techniques that can be used to allocate tasks to devices. We evaluate our techniques using a pathology image analysis application used to investigate brain cancer morphology, and our experimental evaluation shows that the proposed scheduling strategies significantly outperforms other efficient scheduling techniques, such as Heterogeneous Earliest Finish Time - HEFT, in cooperative executions using CPUs, GPUs, and MICs. We also experimentally show that our strategies are less sensitive to inaccuracy in the scheduling input data and that the performance gains are maintained as the application scales.

  9. Efficient Execution of Microscopy Image Analysis on CPU, GPU, and MIC Equipped Cluster Systems

    PubMed Central

    Andrade, G.; Ferreira, R.; Teodoro, George; Rocha, Leonardo; Saltz, Joel H.; Kurc, Tahsin

    2015-01-01

    High performance computing is experiencing a major paradigm shift with the introduction of accelerators, such as graphics processing units (GPUs) and Intel Xeon Phi (MIC). These processors have made available a tremendous computing power at low cost, and are transforming machines into hybrid systems equipped with CPUs and accelerators. Although these systems can deliver a very high peak performance, making full use of its resources in real-world applications is a complex problem. Most current applications deployed to these machines are still being executed in a single processor, leaving other devices underutilized. In this paper we explore a scenario in which applications are composed of hierarchical data flow tasks which are allocated to nodes of a distributed memory machine in coarse-grain, but each of them may be composed of several finer-grain tasks which can be allocated to different devices within the node. We propose and implement novel performance aware scheduling techniques that can be used to allocate tasks to devices. We evaluate our techniques using a pathology image analysis application used to investigate brain cancer morphology, and our experimental evaluation shows that the proposed scheduling strategies significantly outperforms other efficient scheduling techniques, such as Heterogeneous Earliest Finish Time - HEFT, in cooperative executions using CPUs, GPUs, and MICs. We also experimentally show that our strategies are less sensitive to inaccuracy in the scheduling input data and that the performance gains are maintained as the application scales. PMID:26640423

  10. How can sludge dewatering devices be assessed? Development of a new DSS and its application to real case studies.

    PubMed

    Bertanza, Giorgio; Papa, Matteo; Canato, Matteo; Collivignarelli, Maria Cristina; Pedrazzani, Roberta

    2014-05-01

    A key issue in biological Waste Water Treatment Plants (WWTPs) operation is represented by the sludge management. Mechanical dewatering is a crucial stage for sludge volume reduction; though, being a costly operation, its optimization is required. We developed an original experimental methodology to evaluate the technical (dewatering efficiency) and financial (total treatment costs) performance of dewatering devices, which might be used as a DSS (Decision Support System) for WWTP managers. This tool was then applied to two real case studies for comparing, respectively, three industrial size centrifuges, and two different operation modes of the same machine (fixed installation vs. outsourcing service). In both the cases, the best option was identified, based jointly on economic and (site-specific) technical evaluations. Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. New Challenges in Tribology: Wear Assessment Using 3D Optical Scanners

    PubMed Central

    Valigi, Maria Cristina; Logozzo, Silvia; Affatato, Saverio

    2017-01-01

    Wear is a significant mechanical and clinical problem. To acquire further knowledge on the tribological phenomena that involve freeform mechanical components or medical prostheses, wear tests are performed on biomedical and industrial materials in order to solve or reduce failures or malfunctions due to material loss. Scientific and technological advances in the field of optical scanning allow the application of innovative devices for wear measurements, leading to improvements that were unimaginable until a few years ago. It is therefore important to develop techniques, based on new instrumentations, for more accurate and reproducible measurements of wear. The aim of this work is to discuss the use of innovative 3D optical scanners and an experimental procedure to detect and evaluate wear, comparing this technique with other wear evaluation methods for industrial components and biomedical devices. PMID:28772905

  12. New Challenges in Tribology: Wear Assessment Using 3D Optical Scanners.

    PubMed

    Valigi, Maria Cristina; Logozzo, Silvia; Affatato, Saverio

    2017-05-18

    Wear is a significant mechanical and clinical problem. To acquire further knowledge on the tribological phenomena that involve freeform mechanical components or medical prostheses, wear tests are performed on biomedical and industrial materials in order to solve or reduce failures or malfunctions due to material loss. Scientific and technological advances in the field of optical scanning allow the application of innovative devices for wear measurements, leading to improvements that were unimaginable until a few years ago. It is therefore important to develop techniques, based on new instrumentations, for more accurate and reproducible measurements of wear. The aim of this work is to discuss the use of innovative 3D optical scanners and an experimental procedure to detect and evaluate wear, comparing this technique with other wear evaluation methods for industrial components and biomedical devices.

  13. Development of a robotic evaluation system for the ability of proprioceptive sensation in slow hand motion.

    PubMed

    Tanaka, Yoshiyuki; Mizoe, Genki; Kawaguchi, Tomohiro

    2015-01-01

    This paper proposes a simple diagnostic methodology for checking the ability of proprioceptive/kinesthetic sensation by using a robotic device. The perception ability of virtual frictional forces is examined in operations of the robotic device by the hand at a uniform slow velocity along the virtual straight/circular path. Experimental results by healthy subjects demonstrate that percentage of correct answers for the designed perceptual tests changes in the motion direction as well as the arm configuration and the HFM (human force manipulability) measure. It can be supposed that the proposed methodology can be applied into the early detection of neuromuscular/neurological disorders.

  14. Practical device-independent quantum cryptography via entropy accumulation.

    PubMed

    Arnon-Friedman, Rotem; Dupuis, Frédéric; Fawzi, Omar; Renner, Renato; Vidick, Thomas

    2018-01-31

    Device-independent cryptography goes beyond conventional quantum cryptography by providing security that holds independently of the quality of the underlying physical devices. Device-independent protocols are based on the quantum phenomena of non-locality and the violation of Bell inequalities. This high level of security could so far only be established under conditions which are not achievable experimentally. Here we present a property of entropy, termed "entropy accumulation", which asserts that the total amount of entropy of a large system is the sum of its parts. We use this property to prove the security of cryptographic protocols, including device-independent quantum key distribution, while achieving essentially optimal parameters. Recent experimental progress, which enabled loophole-free Bell tests, suggests that the achieved parameters are technologically accessible. Our work hence provides the theoretical groundwork for experimental demonstrations of device-independent cryptography.

  15. Histological evaluation of the influence of magnetic field application in autogenous bone grafts in rats.

    PubMed

    Puricelli, Edela; Dutra, Nardier B; Ponzoni, Deise

    2009-01-11

    Bone grafts are widely used in oral and maxillofacial reconstruction. The influence of electromagnetic fields and magnets on the endogenous stimulation of target tissues has been investigated. This work aimed to assess the quality of bone healing in surgical cavities filled with autogenous bone grafts, under the influence of a permanent magnetic field produced by in vivo buried devices. Metal devices consisting of commercially pure martensitic stainless steel washers and titanium screws were employed. Thirty male Wistar rats were divided into 3 experimental and 3 control groups. A surgical bone cavity was produced on the right femur, and a bone graft was collected and placed in each hole. Two metallic washers, magnetized in the experimental group but not in the control group, were attached on the borders of the cavity. The animals were sacrificed on postoperative days 15, 45 and 60. The histological analysis of control and experimental samples showed adequate integration of the bone grafts, with intense bone neoformation. On days 45 and 60, a continued influence of the magnetic field on the surgical cavity and on the bone graft was observed in samples from the experimental group. The results showed intense bone neoformation in the experimental group as compared to control animals. The intense extra-cortical bone neoformation observed suggests that the osteoconductor condition of the graft may be more susceptible to stimulation, when submitted to a magnetic field.

  16. Field studies of beach cones as coastal erosion control/reversal devices for areas with significant oil and gas activities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1992-07-17

    A field demonstration/study of a novel shoreline erosion protection device called beach cones is planned. These patented, fiberglass- reinforced concreted devices are to be deployed in a number of geometric patterns at seven location in the Bastian Bay area of Western Plaquemines Parish. The purpose of the work described in this report was to evaluate the proposed study's impact on living and non-living shellfish resources within each of the project's seven separate Study Areas. Major accomplishments for this reporting period were as follows: aerial photographs of the experimental sites were taken; all permit applications were filed; information was submitted formore » the Environmental Report; several reconnaissance trips to the experimental sites were made; meetings were held among all participating organizations to further plan the research; permit was obtained from the US Army Corps of Engineers; test sites were surveyed by the Xavier University contingent; survey data were taken at all sites; the Oyster Assessment was completed; permit was obtained from the State of Louisiana Department of Natural Resources; and initial survey data were finalized at all sites.« less

  17. The Measurement of Airflow Using Singing Helmet That Allows Free Movement of the Jaw.

    PubMed

    Jiang, Jack J; Hanna, Rewais B; Willey, Malachi V; Rieves, Adam

    2016-11-01

    Airflow measurement is a useful method of evaluating laryngeal physiology. We introduce a noninvasive device that measures airflow without restricting jaw movement or requiring phonation into a mouthpiece, thus facilitating measurement during singing and connected speech. Validation and human subject trials were conducted. Airflow measurements were obtained from 16 male and 16 female subjects during singing, speech, and constant vowel production tasks. A similar helmet was designed by Stevens and Mead in 1968. The new device validity was evaluated by comparing the measured volume of air to a known volume of administered air using a calibration syringe. Subjects were asked to voice sustained vowels at low, medium, and high vocal intensity, read two sentences at a conversational volume, and perform different singing exercises while airflow was recorded. The device accurately and reliably measured airflow with mean airflow values falling within previously published ranges. There was an experimentally determined response time of 0.173 ± 0.014 seconds. Subjects were able to comfortably perform speech and singing exercises. Male subjects had higher airflow for all sustained vowels (P < 0.05). Airflow was higher for abduction rather than adduction sentences (P < 0.05). No other portable device has been shown to measure airflow during singing and speech while allowing for free movement of the jaw. This device provides a more natural environment to measure airflow that could be used to help evaluate laryngeal function and aid in singing training. Copyright © 2016 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  18. Basic life support: evaluation of learning using simulation and immediate feedback devices1.

    PubMed

    Tobase, Lucia; Peres, Heloisa Helena Ciqueto; Tomazini, Edenir Aparecida Sartorelli; Teodoro, Simone Valentim; Ramos, Meire Bruna; Polastri, Thatiane Facholi

    2017-10-30

    to evaluate students' learning in an online course on basic life support with immediate feedback devices, during a simulation of care during cardiorespiratory arrest. a quasi-experimental study, using a before-and-after design. An online course on basic life support was developed and administered to participants, as an educational intervention. Theoretical learning was evaluated by means of a pre- and post-test and, to verify the practice, simulation with immediate feedback devices was used. there were 62 participants, 87% female, 90% in the first and second year of college, with a mean age of 21.47 (standard deviation 2.39). With a 95% confidence level, the mean scores in the pre-test were 6.4 (standard deviation 1.61), and 9.3 in the post-test (standard deviation 0.82, p <0.001); in practice, 9.1 (standard deviation 0.95) with performance equivalent to basic cardiopulmonary resuscitation, according to the feedback device; 43.7 (standard deviation 26.86) mean duration of the compression cycle by second of 20.5 (standard deviation 9.47); number of compressions 167.2 (standard deviation 57.06); depth of compressions of 48.1 millimeter (standard deviation 10.49); volume of ventilation 742.7 (standard deviation 301.12); flow fraction percentage of 40.3 (standard deviation 10.03). the online course contributed to learning of basic life support. In view of the need for technological innovations in teaching and systematization of cardiopulmonary resuscitation, simulation and feedback devices are resources that favor learning and performance awareness in performing the maneuvers.

  19. Trait and state disgust: an experimental investigation of disgust and avoidance in colorectal cancer decision scenarios.

    PubMed

    Reynolds, Lisa M; McCambridge, Sarah A; Bissett, Ian P; Consedine, Nathan S

    2014-12-01

    To evaluate whether trait and experimentally manipulated state disgust independently and/or interactively predict immediate and anticipated avoidance in decision scenarios related to colorectal cancer (CRC). Eighty participants, aged 18 to 66 years, completed questionnaires assessing trait disgust prior to a laboratory session. Participants were gender block randomized to disgust or control conditions before completing tasks assessing immediate avoidance of a CRC disgust elicitor (stoma bag) and anticipated avoidance in hypothetical CRC scenarios. Manipulation checks confirmed the elicitation of disgust in the experimental condition. Persons in the experimental condition were more likely to exhibit immediate avoidance behaviors in response to a commonly used bowel disease device (stoma bag), and trait disgust predicted time to touch the device. Trait disgust also moderated the influence of state disgust on anticipated avoidance, namely delay in help seeking for bowel symptoms and predicted rating disgusting side effects as more deterring to adherence. The current report suggests the importance of examining disgust in CRC contexts and provides the first empirical demonstration that state and trait aspects of disgust may interactively operate to deter certain types of decisions. It thus furthers understanding of emotions and avoidance in a health context that has had surprisingly little focus to date.

  20. The "Skull Flap" a new conceived device for decompressive craniectomy experimental study on dogs to evaluate the safety and efficacy in reducing intracranial pressure and subsequent impact on brain perfusion.

    PubMed

    Salvatore, Chibbaro; Fabrice, Vallee; Marco, Marsella; Leonardo, Tigan; Thomas, Lilin; Benoit, Lecuelle; Bernard, George; Pierre, Kehrli; Eric, Vicaut; Paolo, Diemidio

    2013-10-01

    Decompressive craniectomy (DC) is a procedure performed increasingly often in current neurosurgical practice. Significant perioperative morbidity may be associated to this procedure because of the large skull defect; also, later closure of the skull defect (cranioplasty) may be associated to post-operative morbidity as much as any other reconstructive operation. The authors present a newly conceived/developed device: The "Skull Flap" (SF). This system, placed at the time of the craniectomy, offers the possibility to provide cranial reconstruction sparing patients a second operation. In other words, DC and cranioplasty essentially take place at the same time and in addition, patients retain their own bone flap. The current study conducted on animal models, represents the logical continuation of a prior recent study, realized on cadaver specimens, to assess the efficacy and safety of this recently developed device. This is an experimental pilot study on dogs to assess both safety and efficacy of the SF device. Two groups of experimental raised intracranial pressure animal models underwent DC; in the first group of dogs, the bone flap was left in raised position above the skull defect using the SF device; on the second group the flap was discarded. All dogs underwent transcranial Doppler (TCD) to assess brain perfusion. Head computed tomography (CT) scan to determine flap position was also obtained in the group in which the SF device was placed. SF has proved to be a strong fixation device that allows satisfactory brain decompression by keeping the bone flap elevated from the swollen brain; later on, the SF allows cranial reconstruction in a simple way without requiring a second staged operation. In addition, it is relevant to note that brain perfusion was measured and found to be better in the group receiving the SF (while the flap being in a raised as well as in its natural position) comparing to the other group. The SF device has proved to be very easy to place, well-adaptable to a different type of flaps and ultimately very effective in maintaining satisfactory brain decompression and later on, making easy bone flap repositioning after brain swelling has subsided.

  1. Computational simulation of biomolecules transport with multi-physics near microchannel surface for development of biomolecules-detection devices.

    PubMed

    Suzuki, Yuma; Shimizu, Tetsuhide; Yang, Ming

    2017-01-01

    The quantitative evaluation of the biomolecules transport with multi-physics in nano/micro scale is demanded in order to optimize the design of microfluidics device for the biomolecules detection with high detection sensitivity and rapid diagnosis. This paper aimed to investigate the effectivity of the computational simulation using the numerical model of the biomolecules transport with multi-physics near a microchannel surface on the development of biomolecules-detection devices. The biomolecules transport with fluid drag force, electric double layer (EDL) force, and van der Waals force was modeled by Newtonian Equation of motion. The model validity was verified in the influence of ion strength and flow velocity on biomolecules distribution near the surface compared with experimental results of previous studies. The influence of acting forces on its distribution near the surface was investigated by the simulation. The trend of its distribution to ion strength and flow velocity was agreement with the experimental result by the combination of all acting forces. Furthermore, EDL force dominantly influenced its distribution near its surface compared with fluid drag force except for the case of high velocity and low ion strength. The knowledges from the simulation might be useful for the design of biomolecules-detection devices and the simulation can be expected to be applied on its development as the design tool for high detection sensitivity and rapid diagnosis in the future.

  2. Testing an innovative device against airborne Aspergillus contamination.

    PubMed

    Desoubeaux, Guillaume; Bernard, Marie-Charlotte; Gros, Valérie; Sarradin, Pierre; Perrodeau, Elodie; Vecellio, Laurent; Piscopo, Antoine; Chandenier, Jacques; Bernard, Louis

    2014-08-01

    Aspergillus fumigatus is a major airborne nosocomial pathogen that is responsible for severe mycosis in immunocompromised patients. We studied the efficacy of an innovative mobile air-treatment device in eliminating A. fumigatus from the air following experimental massive contamination in a high-security room. Viable mycological particles were isolated from sequential air samples in order to evaluate the device's effectiveness in removing the fungus. The concentration of airborne conidia was reduced by 95% in 18 min. Contamination was reduced below the detection threshold in 29 min, even when the machine was at the lowest airflow setting. In contrast, during spontaneous settling with no air treatment, conidia remained airborne for more than 1 h. This indoor air contamination model provided consistent and reproducible results. Because the air purifier proved to be effective at eliminating a major contaminant, it may prove useful in preventing air-transmitted disease agents. In an experimental space mimicking a hospital room, the AirLyse air purifier, which uses a combination of germicidal ultraviolet C irradiation and titanium photocatalysis, effectively eliminated Aspergillus conidia. Such a mobile device may be useful in routine practice for lowering microbiological air contamination in the rooms of patients at risk. © The Author 2014. Published by Oxford University Press on behalf of The International Society for Human and Animal Mycology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  3. The effect of simulated field storage conditions on the accuracy of rapid user-friendly blood pathogen detection kits.

    PubMed

    Bienek, Diane R; Charlton, David G

    2012-05-01

    Being able to test for the presence of blood pathogens at forward locations could reduce morbidity and mortality in the field. Rapid, user-friendly blood typing kits for detecting Human Immunodeficiency Virus (HIV), Hepatitis C Virus (HCV), and Hepatitis B Virus (HBV) were evaluated to determine their accuracy after storage at various temperatures/humidities. Rates of positive tests of control groups, experimental groups, and industry standards were compared (Fisher's exact chi2, p < or = 0.05). Compared to the control group, 2 of 10 HIV detection devices were adversely affected by exposure to high temperature/high humidity or high temperature/low humidity. With one exception, none of the environmentally exposed HCV or HBV detection devices exhibited significant differences compared to those stored under control conditions. For HIV, HCV, and HBV devices, there were differences compared to the industry standard. Collectively, this evaluation of pathogen detection kits revealed that diagnostic performance varies among products and storage conditions, and that the tested products cannot be considered to be approved for use to screen blood, plasma, cell, or tissue donors.

  4. Generating a Corpus of Mobile Forensic Images for Masquerading user Experimentation.

    PubMed

    Guido, Mark; Brooks, Marc; Grover, Justin; Katz, Eric; Ondricek, Jared; Rogers, Marcus; Sharpe, Lauren

    2016-11-01

    The Periodic Mobile Forensics (PMF) system investigates user behavior on mobile devices. It applies forensic techniques to an enterprise mobile infrastructure, utilizing an on-device agent named TractorBeam. The agent collects changed storage locations for later acquisition, reconstruction, and analysis. TractorBeam provides its data to an enterprise infrastructure that consists of a cloud-based queuing service, relational database, and analytical framework for running forensic processes. During a 3-month experiment with Purdue University, TractorBeam was utilized in a simulated operational setting across 34 users to evaluate techniques to identify masquerading users (i.e., users other than the intended device user). The research team surmises that all masqueraders are undesirable to an enterprise, even when a masquerader lacks malicious intent. The PMF system reconstructed 821 forensic images, extracted one million audit events, and accurately detected masqueraders. Evaluation revealed that developed methods reduced storage requirements 50-fold. This paper describes the PMF architecture, performance of TractorBeam throughout the protocol, and results of the masquerading user analysis. © 2016 American Academy of Forensic Sciences.

  5. Applicability of a new robotic walking aid in a patient with cerebral palsy. Case report.

    PubMed

    Smania, N; Gandolfi, M; Marconi, V; Calanca, A; Geroin, C; Piazza, S; Bonetti, P; Fiorini, P; Cosentino, A; Capelli, C; Conte, D; Bendinelli, M; Munari, D; Ianes, P; Fiaschi, A; Picelli, A

    2012-03-01

    Gait training with the help of assistive technological devices is an innovative field of research in neurological rehabilitation. Most of the available gait training devices do not allow free movement in the environment, which would be the most suitable natural and motivating condition for training children with neurological gait impairment. To evaluate the potential applicability of a new robotic walking aid as a tool for gait training in non-ambulatory children with Cerebral Palsy. Single case study Outpatient regimen A 11-years-old child unable to stand and walk independently as a result of spastic tetraplegic cerebral palsy (CP). The experimental device was a newly actuated version of a dynamic combined walking and standing aid (NF-Walker®) available in the market which was modified by means of two pneumatic artificial muscles driven by a foot-switch inserted in the shoes. The child was tested at baseline (while maintaining the standing position aided by the non-actuated NF-Walker®) and in the experimental condition (while using the actuated robotic aid). The outcome measures were: 2-minute walking test, 10-metre walking test, respiratory and heart parameters, energy cost of locomotion. At baseline, the child was unable to perform any autonomous form of locomotion. When assisted by the actuated aid (i.e. during the experimental condition), the child was successful in moving around in his environment. His performance was 19.63 m in the 2-minute walking test and 64 s in the 10-metre walking test. Respiratory and heart parameters were higher than healthy age-matched children both at baseline and in the experimental condition. The energy cost of gait, which was not valuable in the baseline condition, was significantly higher than normality during the experimental condition. The new robotic walking aid may help children suffering from CP with severe impairment of gait to move around in their environment. This new robotic walking device may have a potential impact in stimulating the development and in training of gait in children with neurological gait impairment. Future studies are warranted in order to test this hypothesis.

  6. The evaluation of uncertainty in low-level LSC measurements of water samples.

    PubMed

    Rusconi, R; Forte, M; Caresana, M; Bellinzona, S; Cazzaniga, M T; Sgorbati, G

    2006-01-01

    The uncertainty in measurements of gross alpha and beta activities in water samples by liquid scintillation counting with alpha/beta discrimination has been evaluated considering the problems typical of low-level measurements of environmental samples. The use of a pulse shape analysis device to discriminate alpha and beta events introduces a correlation between some of the input quantities, and it has to be considered. Main contributors to total uncertainty have been assessed by specifically designed experimental tests. Results have been fully examined and discussed.

  7. Effect of Enrichment Devices on Aggression in Manipulated Nude Mice.

    PubMed

    Lockworth, Cynthia R; Kim, Sun-Jin; Liu, Jun; Palla, Shana L; Craig, Suzanne L

    2015-11-01

    Agonistic behavior in group-housed male mice is a recurring problem in many animal research facilities. Common management procedures, such as the removal of aggressors, are moderately successful but often fail, owing to recurrence of aggressive behavior among cagemates. Studies have incorporated enrichment devices to attenuate aggression, but such devices have had mixed results. However, these studies did not include research manipulations when assessing the benefits of various enrichment devices. We obtained 100 male athymic nude mice and studied the efficacy of various enrichment devices, including cotton squares, paper rolls, shredded paper, nylon bones, and a mouse house and wheel combination in the reduction of fighting during an ongoing study that involved randomization followed by prostate and intratibial injections. Groups were evaluated according to a numerical grading system for wound assessment. Examination of the data revealed that the enrichment devices had no effect on the presence of wounds, thus none of the devices tested affected fighting in nude mice. However, when mice began experimental use, fight wounds increased significantly at cage change and after randomization, reflecting a disruption of existing social hierarchies. Therefore, in the context of an actual research study that involves common manipulations, the specific enrichment device had less effect on aggression in male nude mice than did the destruction and reconstruction of social structures within each group.

  8. Theoretical and Experimental Investigation of Particle Trapping via Acoustic Bubbles

    NASA Astrophysics Data System (ADS)

    Chen, Yun; Fang, Zecong; Merritt, Brett; Saadat-Moghaddam, Darius; Strack, Dillon; Xu, Jie; Lee, Sungyon

    2014-11-01

    One important application of lab-on-a-chip devices is the trapping and sorting of micro-objects, with acoustic bubbles emerging as an effective, non-contact method. Acoustically actuated bubbles are known to exert a secondary radiation force on micro-particles and trap them, when this radiation force exceeds the drag force that acts to keep the particles in motion. In this study, we theoretically evaluate the magnitudes of these two forces for varying actuation frequencies and voltages. In particular, the secondary radiation force is calculated directly from bubble oscillation shapes that have been experimentally measured for varying acoustic parameters. Finally, based on the force estimates, we predict the threshold voltage and frequency for trapping and compare them to the experimental results.

  9. Respiratory monitoring system based on the nasal pressure technique for the analysis of sleep breathing disorders: Reduction of static and dynamic errors, and comparisons with thermistors and pneumotachographs

    NASA Astrophysics Data System (ADS)

    Alves de Mesquita, Jayme; Lopes de Melo, Pedro

    2004-03-01

    Thermally sensitive devices—thermistors—have usually been used to monitor sleep-breathing disorders. However, because of their long time constant, these devices are not able to provide a good characterization of fast events, like hypopneas. Nasal pressure recording technique (NPR) has recently been suggested to quantify airflow during sleep. It is claimed that the short time constants of the devices used to implement this technique would allow an accurate analysis of fast abnormal respiratory events. However, these devices present errors associated with nonlinearities and acoustic resonance that could reduce the diagnostic value of the NPR. Moreover, in spite of the high scientific and clinical potential, there is no detailed description of a complete instrumentation system to implement this promising technique in sleep studies. In this context, the purpose of this work was twofold: (1) describe the development of a flexible NPR device and (2) evaluate the performance of this device when compared to pneumotachographs (PNTs) and thermistors. After the design details are described, the system static accuracy is evaluated by a comparative analysis with a PNT. This analysis revealed a significant reduction (p<0.001) of the static error when system nonlinearities were reduced. The dynamic performance of the NPR system was investigated by frequency response analysis and time constant evaluations and the results showed that the developed device response was as good as PNT and around 100 times faster (τ=5,3 ms) than thermistors (τ=512 ms). Experimental results obtained in simulated clinical conditions and in a patient are presented as examples, and confirmed the good features achieved in engineering tests. These results are in close agreement with physiological fundamentals, supplying substantial evidence that the improved dynamic and static characteristics of this device can contribute to a more accurate implementation of medical research projects and to improve the diagnoses of sleep-breathing disorders.

  10. Development and evaluation of a soft wearable weight support device for reducing muscle fatigue on shoulder

    PubMed Central

    Cho, Kyu-Jin

    2017-01-01

    Compensating the weight of human limbs is important in reducing muscle fatigue experienced by manual laborers. In this study, a compact and lightweight soft wearable weight support device was developed and evaluated. The device supports gravitational force on the shoulder at any arm posture, although there are some limitations in its assistive performance. The device actuator consists of a cam-rod structure, a tendon-driven mechanism, and a rubber band. The desired assistive torque is translated to the shoulder joint along a tendon routing structure. Device performance was evaluated by measuring muscle activation in with-assist and without-assist conditions. Muscle activation on the deltoid was measured by surface electromyography. An experimental protocol consisting of a series of exercises was executed with six healthy subjects. The subjects raised and lowered their arm from 0 to 100 degrees for 30 times under eight conditions, which were combined with-assist and without-assist conditions, and holding the horizontal angle of the arm at 0, 30, 60, or 90 degrees against the sagittal plane. Surface electromyography data were pre-processed and analyzed using a root mean square method. When muscle fatigue occurs, the root mean square of the surface electromyography increases nonlinearly. This was calculated using the standard deviation of the root mean square. Three of six subjects showed decreased variation of the root mean square between the exercises in the with-assist condition. One subject’s result was significantly reduced (by about 57.6%) in the with-assist condition. In contrast, two subjects did not show significant difference between measurements taken in the with-assist and without-assist conditions. One subject was dropped from the experiment because the device did not fit the subject’s body. In conclusion, the effectiveness of the soft wearable weight support device in supporting shoulder movements was verified through the decreased variation of muscle activation. PMID:28291825

  11. Development and evaluation of a soft wearable weight support device for reducing muscle fatigue on shoulder.

    PubMed

    Park, Daegeun; Cho, Kyu-Jin

    2017-01-01

    Compensating the weight of human limbs is important in reducing muscle fatigue experienced by manual laborers. In this study, a compact and lightweight soft wearable weight support device was developed and evaluated. The device supports gravitational force on the shoulder at any arm posture, although there are some limitations in its assistive performance. The device actuator consists of a cam-rod structure, a tendon-driven mechanism, and a rubber band. The desired assistive torque is translated to the shoulder joint along a tendon routing structure. Device performance was evaluated by measuring muscle activation in with-assist and without-assist conditions. Muscle activation on the deltoid was measured by surface electromyography. An experimental protocol consisting of a series of exercises was executed with six healthy subjects. The subjects raised and lowered their arm from 0 to 100 degrees for 30 times under eight conditions, which were combined with-assist and without-assist conditions, and holding the horizontal angle of the arm at 0, 30, 60, or 90 degrees against the sagittal plane. Surface electromyography data were pre-processed and analyzed using a root mean square method. When muscle fatigue occurs, the root mean square of the surface electromyography increases nonlinearly. This was calculated using the standard deviation of the root mean square. Three of six subjects showed decreased variation of the root mean square between the exercises in the with-assist condition. One subject's result was significantly reduced (by about 57.6%) in the with-assist condition. In contrast, two subjects did not show significant difference between measurements taken in the with-assist and without-assist conditions. One subject was dropped from the experiment because the device did not fit the subject's body. In conclusion, the effectiveness of the soft wearable weight support device in supporting shoulder movements was verified through the decreased variation of muscle activation.

  12. Design, Construction and Testing of Annular Diffusers for High Speed Civil Transportation Combustor Applications

    NASA Technical Reports Server (NTRS)

    Okhio, Cyril B.

    1996-01-01

    A theoretical and an experimental design study of subsonic flow through curved-wall annular diffusers has been initiated under this award in order to establish the most pertinent design parameters and hence performance characteristics for such devices, an the implications of their application in the design of engine components in the aerospace industries. The diffusers under this study are expected to contain appreciable regions of stall and the effects of swirl on their performance are being studied. The experimental work involves the application of Computer Aided Design software tool to the development of a suitable annular diffuse geometry and the subsequent downloading of such data to a CNC machine at Central State University (CSU). Two experimental run segments have been completed so far during FY-95 involving flow visualization and diffuser performance evaluation based on Kinetic Energy Dissipation. The method of calculation of the performance of diffusers based on pressure recovery coefficient has been shown to have some shortcomings and so the kinetic energy dissipation approach has been introduced in the run segment two with some success. The application of the discretized, full Navier Stokes and Continuity equations to the numerical study of the problem described above for the time-mean flow is expected to follow. Various models of turbulence are being evaluated for adoption throughout the study and comparisons would be made with experimental data where they exist. Assessment of diffuser performance based on the dissipated mechanical energy would also be made. The result of the investigations are expected to indicate that more cost effective component design of such devices as diffusers which normally contain complex flows can still be achieved.

  13. Heuristic Evaluation on Mobile Interfaces: A New Checklist

    PubMed Central

    Yáñez Gómez, Rosa; Cascado Caballero, Daniel; Sevillano, José-Luis

    2014-01-01

    The rapid evolution and adoption of mobile devices raise new usability challenges, given their limitations (in screen size, battery life, etc.) as well as the specific requirements of this new interaction. Traditional evaluation techniques need to be adapted in order for these requirements to be met. Heuristic evaluation (HE), an Inspection Method based on evaluation conducted by experts over a real system or prototype, is based on checklists which are desktop-centred and do not adequately detect mobile-specific usability issues. In this paper, we propose a compilation of heuristic evaluation checklists taken from the existing bibliography but readapted to new mobile interfaces. Selecting and rearranging these heuristic guidelines offer a tool which works well not just for evaluation but also as a best-practices checklist. The result is a comprehensive checklist which is experimentally evaluated as a design tool. This experimental evaluation involved two software engineers without any specific knowledge about usability, a group of ten users who compared the usability of a first prototype designed without our heuristics, and a second one after applying the proposed checklist. The results of this experiment show the usefulness of the proposed checklist for avoiding usability gaps even with nontrained developers. PMID:25295300

  14. Xurography as a Rapid Fabrication Alternative for Point-of-Care Devices: Assessment of Passive Micromixers

    PubMed Central

    Martínez-López, J. Israel; Mojica, Mauricio; Rodríguez, Ciro A.; Siller, Héctor R.

    2016-01-01

    Despite the copious amount of research on the design and operation of micromixers, there are few works regarding manufacture technology aimed at implementation beyond academic environments. This work evaluates the viability of xurography as a rapid fabrication tool for the development of ultra-low cost microfluidic technology for extreme Point-of-Care (POC) micromixing devices. By eschewing photolithographic processes and the bulkiness of pumping and enclosure systems for rapid fabrication and passively driven operation, xurography is introduced as a manufacturing alternative for asymmetric split and recombine (ASAR) micromixers. A T-micromixer design was used as a reference to assess the effects of different cutting conditions and materials on the geometric features of the resulting microdevices. Inspection by stereographic and confocal microscopy showed that it is possible to manufacture devices with less than 8% absolute dimensional error. Implementation of the manufacturing methodology in modified circular shape- based SAR microdevices (balanced and unbalanced configurations) showed that, despite the precision limitations of the xurographic process, it is possible to implement this methodology to produce functional micromixing devices. Mixing efficiency was evaluated numerically and experimentally at the outlet of the microdevices with performances up to 40%. Overall, the assessment encourages further research of xurography for the development of POC micromixers. PMID:27196904

  15. Xurography as a Rapid Fabrication Alternative for Point-of-Care Devices: Assessment of Passive Micromixers.

    PubMed

    Martínez-López, J Israel; Mojica, Mauricio; Rodríguez, Ciro A; Siller, Héctor R

    2016-05-16

    Despite the copious amount of research on the design and operation of micromixers, there are few works regarding manufacture technology aimed at implementation beyond academic environments. This work evaluates the viability of xurography as a rapid fabrication tool for the development of ultra-low cost microfluidic technology for extreme Point-of-Care (POC) micromixing devices. By eschewing photolithographic processes and the bulkiness of pumping and enclosure systems for rapid fabrication and passively driven operation, xurography is introduced as a manufacturing alternative for asymmetric split and recombine (ASAR) micromixers. A T-micromixer design was used as a reference to assess the effects of different cutting conditions and materials on the geometric features of the resulting microdevices. Inspection by stereographic and confocal microscopy showed that it is possible to manufacture devices with less than 8% absolute dimensional error. Implementation of the manufacturing methodology in modified circular shape- based SAR microdevices (balanced and unbalanced configurations) showed that, despite the precision limitations of the xurographic process, it is possible to implement this methodology to produce functional micromixing devices. Mixing efficiency was evaluated numerically and experimentally at the outlet of the microdevices with performances up to 40%. Overall, the assessment encourages further research of xurography for the development of POC micromixers.

  16. Manufacturing process of nanofluidics using afm probe

    NASA Astrophysics Data System (ADS)

    Karingula, Varun Kumar

    A new process for fabricating a nano fluidic device that can be used in medical application is developed and demonstrated. Nano channels are fabricated using a nano tip in indentation mode on AFM (Atomic Force Microscopy). The nano channels are integrated between the micro channels and act as a filter to separate biomolecules. Nano channels of 4 to7 m in length, 80nm in width, and at varying depths from 100nm to 850 nm allow the resulting device to separate selected groups of lysosomes and other viruses. Sharply developed vertical micro channels are produced from a deep reaction ion etching followed by deposition of different materials, such as gold and polymers, on the top surface, allowing the study of alternative ways of manufacturing a nanofluidic device. PDMS (Polydimethylsiloxane) bonding is performed to close the top surface of the device. An experimental setup is used to test and validate the device by pouring fluid through the channels. A detailed cost evaluation is conducted to compare the economical merits of the proposed process. It is shown that there is a 47:7% manufacturing time savings and a 60:6% manufacturing cost savings.

  17. Impact of device level faults in a digital avionic processor

    NASA Technical Reports Server (NTRS)

    Suk, Ho Kim

    1989-01-01

    This study describes an experimental analysis of the impact of gate and device-level faults in the processor of a Bendix BDX-930 flight control system. Via mixed mode simulation, faults were injected at the gate (stuck-at) and at the transistor levels and, their propagation through the chip to the output pins was measured. The results show that there is little correspondence between a stuck-at and a device-level fault model, as far as error activity or detection within a functional unit is concerned. In so far as error activity outside the injected unit and at the output pins are concerned, the stuck-at and device models track each other. The stuck-at model, however, overestimates, by over 100 percent, the probability of fault propagation to the output pins. An evaluation of the Mean Error Durations and the Mean Time Between Errors at the output pins shows that the stuck-at model significantly underestimates (by 62 percent) the impact of an internal chip fault on the output pins. Finally, the study also quantifies the impact of device fault by location, both internally and at the output pins.

  18. An experimental evaluation of monochromatic x-ray beam position monitors at diamond light source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bloomer, Chris, E-mail: chris.bloomer@diamond.ac.uk; Rehm, Guenther; Dolbnya, Igor P.

    Maintaining the stability of the X-ray beam relative to the sample point is of paramount importance for beamlines and users wanting to perform cutting-edge experiments. The ability to detect, and subsequently compensate for, variations in X-ray beam position with effective diagnostics has multiple benefits: a reduction in commissioning and start-up time, less ‘down-time’, and an improvement in the quality of acquired data. At Diamond Light Source a methodical evaluation of a selection of monochromatic X-ray Beam Position Monitors (XBPMs), using a range of position detection techniques, and from a range of suppliers, was carried out. The results of these experimentsmore » are presented, showing the measured RMS noise on the position measurement of each device for a given flux, energy, beam size, and bandwidth. A discussion of the benefits and drawbacks of each of the various devices and techniques is also included.« less

  19. Evaluation of Information Leakage via Electromagnetic Emanation and Effectiveness of Tempest

    NASA Astrophysics Data System (ADS)

    Tanaka, Hidema

    It is well known that there is relationship between electromagnetic emanation and processing information in IT devices such as personal computers and smart cards. By analyzing such electromagnetic emanation, eavesdropper will be able to get some information, so it becomes a real threat of information security. In this paper, we show how to estimate amount of information that is leaked as electromagnetic emanation. We assume the space between the IT device and the receiver is a communication channel, and we define the amount of information leakage via electromagnetic emanations by its channel capacity. By some experimental results of Tempest, we show example estimations of amount of information leakage. Using the value of channel capacity, we can calculate the amount of information per pixel in the reconstructed image. And we evaluate the effectiveness of Tempest fonts generated by Gaussian method and its threshold of security.

  20. Electromyographic analysis of the masseter and buccinator muscles with the pro-fono facial exerciser use in bruxers.

    PubMed

    Jardini, Renata S R; Ruiz, Lydia S R; Moysés, Maria A A

    2006-01-01

    The aim of this study was to evaluate the efficiency of the Pró-Fono Facial Exerciser (Pró-Fono Productos Especializados para Fonoaudiologia Ltda., Barueri/SP, Brazil) to decrease bruxism, as well as the correlation between the masseter and the buccinator muscles using electromyography (EMG). In this study, 39 individuals ranging from 23 to 48 years of age were selected from a dental school and then underwent surface EMG at three different periods of time: 0, 10, and 70 days. They were divided into a normal control group, a bruxer control group (without device), and an experimental bruxer group who used the device. The bruxer group showed a greater masseter EMG amplitude when compared to the normal group, while the experimental group had deceased activity with a reduction in symptoms. The buccinator EMG spectral analysis of the experimental bruxist group showed asynchronous contractions of the masseter muscle (during jaw opening) after using the Pró-Fono Facial Exerciser. The normal group also showed asynchronous contractions. Upon correlation of the data between these muscles, the inference is that there is a reduction in bruxism when activating the buccinator muscle.

  1. Experimental comparisons between McKibben type artificial muscles and straight fibers type artificial muscles

    NASA Astrophysics Data System (ADS)

    Nakamura, Taro

    2007-01-01

    This paper describes experimental comparison between a conventional McKibben type artificial muscle and a straight fibers type artificial muscle developed by the authors. A wearable device and a rehabilitation robot which assists a human muscle should have characteristics similar to those of human muscle. In addition, because the wearable device and the rehabilitation robot should be light, an actuator with a high power/weight ratio is needed. At present, the McKibben type is widely used as an artificial muscle, but in fact its physical model is highly nonlinear. Further, the heat and mechanical loss of this actuator are large because of the friction caused by the expansion and contraction of the sleeve. Therefore, the authors have developed an artificial muscle tube in which high strength glass fibers have been built into the tube made from natural latex rubber. As results, experimental results demonstrated that the developed artificial muscle is more effective regarding its fundamental characteristics than that of the McKibben type; the straight fibers types of artificial muscle have more contraction ratio and power, longer lifetime than the McKibben types. And it has almost same characteristics of human muscle for isotonic and isometric that evaluate it dynamically.

  2. Experimental Assessment of the Hydraulics of a Miniature Axial-Flow Left Ventricular Assist Device

    NASA Astrophysics Data System (ADS)

    Smith, P. Alex; Cohn, William; Metcalfe, Ralph

    2017-11-01

    A minimally invasive partial-support left ventricular assist device (LVAD) has been proposed with a flow path from the left atrium to the arterial system to reduce left ventricular stroke work. In LVAD design, peak and average efficiency must be balanced over the operating range to reduce blood trauma. Axial flow pumps have many geometric parameters. Until recently, testing all these parameters was impractical, but modern 3D printing technology enables multi-parameter studies. Following theoretical design, experimental hydraulic evaluation in steady state conditions examines pressure, flow, pressure-flow gradient, efficiency, torque, and axial force as output parameters. Preliminary results suggest that impeller blades and stator vanes with higher inlet angles than recommended by mean line theory (MLT) produce flatter gradients and broader efficiency curves, increasing compatibility with heart physiology. These blades also produce less axial force, which reduces bearing load. However, they require slightly higher torque, which is more demanding of the motor. MLT is a low order, empirical model developed on large pumps. It does not account for the significant viscous losses in small pumps like LVADs. This emphasizes the importance of experimental testing for hydraulic design. Roderick D MacDonald Research Fund.

  3. Experimental method of in-vivo dosimetry without build-up device on the skin for external beam radiotherapy

    NASA Astrophysics Data System (ADS)

    Jeon, Hosang; Nam, Jiho; Lee, Jayoung; Park, Dahl; Baek, Cheol-Ha; Kim, Wontaek; Ki, Yongkan; Kim, Dongwon

    2015-06-01

    Accurate dose delivery is crucial to the success of modern radiotherapy. To evaluate the dose actually delivered to patients, in-vivo dosimetry (IVD) is generally performed during radiotherapy to measure the entrance doses. In IVD, a build-up device should be placed on top of an in-vivo dosimeter to satisfy the electron equilibrium condition. However, a build-up device made of tissue-equivalent material or metal may perturb dose delivery to a patient, and requires an additional laborious and time-consuming process. We developed a novel IVD method using a look-up table of conversion ratios instead of a build-up device. We validated this method through a monte-carlo simulation and 31 clinical trials. The mean error of clinical IVD is 3.17% (standard deviation: 2.58%), which is comparable to that of conventional IVD methods. Moreover, the required time was greatly reduced so that the efficiency of IVD could be improved for both patients and therapists.

  4. IR Hiding: A Method to Prevent Video Re-shooting by Exploiting Differences between Human Perceptions and Recording Device Characteristics

    NASA Astrophysics Data System (ADS)

    Yamada, Takayuki; Gohshi, Seiichi; Echizen, Isao

    A method is described to prevent video images and videos displayed on screens from being re-shot by digital cameras and camcorders. Conventional methods using digital watermarking for re-shooting prevention embed content IDs into images and videos, and they help to identify the place and time where the actual content was shot. However, these methods do not actually prevent digital content from being re-shot by camcorders. We developed countermeasures to stop re-shooting by exploiting the differences between the sensory characteristics of humans and devices. The countermeasures require no additional functions to use-side devices. It uses infrared light (IR) to corrupt the content recorded by CCD or CMOS devices. In this way, re-shot content will be unusable. To validate the method, we developed a prototype system and implemented it on a 100-inch cinema screen. Experimental evaluations showed that the method effectively prevents re-shooting.

  5. A Laboratory Experimental Study: An FBG-PVC Tube Integrated Device for Monitoring the Slip Surface of Landslides.

    PubMed

    Wang, Kai; Zhang, Shaojie; Chen, Jiang; Teng, Pengxiao; Wei, Fangqiang; Chen, Qiao

    2017-10-30

    A new detection device was designed by integrating fiber Bragg grating (FBG) and polyvinyl chloride (PVC) tube in order to monitor the slip surface of a landslide. Using this new FBG-based device, a corresponding slope model with a pre-set slip surface was designed, and seven tests with different soil properties were carried out in laboratory conditions. The FBG sensing fibers were fixed on the PVC tube to measure strain distributions of PVC tube at different elevation. Test results indicated that the PVC tube could keep deformation compatible with soil mass. The new device was able to monitor slip surface location before sliding occurrence, and the location of monitored slip surface was about 1-2 cm above the pre-set slip surface, which basically agreed with presupposition results. The monitoring results are expected to be used to pre-estimate landslide volume and provide a beneficial option for evaluating the potential impact of landslides on shipping safety in the Three Gorges area.

  6. Estimation of missing values in solar radiation data using piecewise interpolation methods: Case study at Penang city

    NASA Astrophysics Data System (ADS)

    Zainudin, Mohd Lutfi; Saaban, Azizan; Bakar, Mohd Nazari Abu

    2015-12-01

    The solar radiation values have been composed by automatic weather station using the device that namely pyranometer. The device is functions to records all the radiation values that have been dispersed, and these data are very useful for it experimental works and solar device's development. In addition, for modeling and designing on solar radiation system application is needed for complete data observation. Unfortunately, lack for obtained the complete solar radiation data frequently occur due to several technical problems, which mainly contributed by monitoring device. Into encountering this matter, estimation missing values in an effort to substitute absent values with imputed data. This paper aimed to evaluate several piecewise interpolation techniques likes linear, splines, cubic, and nearest neighbor into dealing missing values in hourly solar radiation data. Then, proposed an extendable work into investigating the potential used of cubic Bezier technique and cubic Said-ball method as estimator tools. As result, methods for cubic Bezier and Said-ball perform the best compare to another piecewise imputation technique.

  7. A Laboratory Experimental Study: An FBG-PVC Tube Integrated Device for Monitoring the Slip Surface of Landslides

    PubMed Central

    Zhang, Shaojie; Chen, Jiang; Teng, Pengxiao; Wei, Fangqiang; Chen, Qiao

    2017-01-01

    A new detection device was designed by integrating fiber Bragg grating (FBG) and polyvinyl chloride (PVC) tube in order to monitor the slip surface of a landslide. Using this new FBG-based device, a corresponding slope model with a pre-set slip surface was designed, and seven tests with different soil properties were carried out in laboratory conditions. The FBG sensing fibers were fixed on the PVC tube to measure strain distributions of PVC tube at different elevation. Test results indicated that the PVC tube could keep deformation compatible with soil mass. The new device was able to monitor slip surface location before sliding occurrence, and the location of monitored slip surface was about 1–2 cm above the pre-set slip surface, which basically agreed with presupposition results. The monitoring results are expected to be used to pre-estimate landslide volume and provide a beneficial option for evaluating the potential impact of landslides on shipping safety in the Three Gorges area. PMID:29084157

  8. Emissions from street vendor cooking devices (charcoal grilling). Final report, January 1998--March 1999

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, S.Y.

    1999-06-01

    The report discusses a joint US/Mexican program to establish a reliable emissions inventory for street vendor cooking devices (charcoal grilling), a significant source of air pollutants in the Mexicali-Imperial Valley area of Mexico. Emissions from these devices, prevalent in the streets of Mexicali, Mexico, were investigated experimentally by measuring levels of particulate matter, particle size distributions, volatile and semivolatile organic compounds, aldehydes, and oxides of nitrogen and sulfur, emitted when meat is cooked on a grill over a charcoal fire. To investigate the emission rate, both beef and chicken were tested. Furthermore, both meats were marinated with a mixture similarmore » to that used by the street vendors. Some tests were conducted with non-marinated beef for comparison. Two blank runs were performed sampling charcoal fires without meat. Finally, a simple control device, normally used in an exhaust fan to trap grease over a kitchen stove, was evaluated for its effectiveness in reducing emissions.« less

  9. "Johnny Poppers": a cause of serious ocular injury

    PubMed Central

    MacAndie, K.; Kyle, P.

    1998-01-01

    AIMS/BACKGROUND—The causes of blunt ocular trauma are many and diverse. We present two cases of ocular injury caused by an unusual form of weapon called a "Johnny Popper". There follows a theoretical and experimental evaluation of the velocity of the projectiles fired by this device.
METHODS—A Johnny Popper was constructed under expert guidance. The elastic properties of the device were measured and this allowed calculation of a theoretical exit velocity of the projectiles fired. The weapon was subsequently fired under test conditions which permitted the exit velocity of the projectiles fired to be measured directly.
RESULTS—The theoretical velocity of the projectiles was calculated as 80 ms-1 and the experimentally measured velocity was 57 ms-1.
CONCLUSIONS—Johnny Poppers are a previously undescribed and unique form of home made weapon. They are intended for playful mischief, but have the potential to cause serious ocular trauma.

 Keywords: ocular trauma; projectiles PMID:9924377

  10. Blood absorption during 970 and 1470 nm laser radiation in vitro.

    PubMed

    Shaydakov, E; Ilyukhin, E; Rosukhovskiy, D

    2015-10-01

    Soon after introduction of water lasers in medical practice for EVLA, less power and energy line density have been used. However, there are no experimental grounds for different energy modes and there is no clear evidence for a difference in the effect of the two wavelengths dealt with in this study. The goal of this study was to evaluate the temperature profile of various laser action modes with testing devices. Three experimental testing devices consisted of cylinders filled with whole donor blood and a set of temperature sensors installed in different positions. We have determined the range of temperatures around the fiber tip of 970 and 1470 nm lasers. The average temperature of 970 nm laser at 1 mm distance along the axis from the fiber tip substantially differed from that of 1470 nm laser, power being equal. Statistically substantial differences were found in endovenous laser ablation simulation in vitro for the 970 nm and 1470 nm laser radiation. Similar temperatures can be reached with 970 nm lasers if power is increased.

  11. Experimental research of heterogeneous nuclei in superheated steam

    NASA Astrophysics Data System (ADS)

    Bartoš, Ondřej; Kolovratník, Michal; Šmíd, Bohuslav; Hrubý, Jan

    2016-03-01

    A mobile steam expansion chamber has been developed to investigate experimentally homogeneous and heterogeneous nucleation processes in steam, both in the laboratory and at power plants using the steam withdrawn from the steam turbine. The purpose of the device is to provide new insight into the physics of nonequilibrium wet steam formation, which is one of the factors limiting the efficiency and reliability of steam turbines. The expanded steam or a mixture of steam with a non-condensable gas rapidly expands in the expansion chamber. Due to adiabatic cooling, the temperature drops below the dew point of the steam at a given pressure. When reaching a sufficiently high supersaturation, droplets are nucleated. By tuning the supersaturation in the so-called nucleation pulse, particles of various size ranges can be activated. This fact is used in the present study to measure the aerosol particles present in the air. Homogeneous nucleation was negligible in this case. The experiment demonstrates the functionality of the device, data acquisition system and data evaluation methods.

  12. Neutron-diffraction measurement of residual stresses in Al-Cu cold-cut welding

    NASA Astrophysics Data System (ADS)

    Fiori, F.; Marcantoni, M.

    Usually, when it is necessary to join different materials with a large difference in their melting points, welding should be avoided. To overcome this problem we designed and built a device to obtain cold-cut welding, which is able to strongly decrease oxidation problems of the surfaces to be welded. Thanks to this device it is possible to achieve good joining between different pairs of materials (Al-Ti, Cu-Al, Cu-Al alloys) without reaching the material melting point. The mechanical and microstructural characterisation of the joining and the validation of its quality were obtained using several experimental methods. In particular, in this work neutron-diffraction experiments for the evaluation of residual stresses in Cu-Al junctions are described, carried out at the G5.2 diffractometer of LLB, Saclay. Neutron-diffraction results are presented and related to other experimental tests such as microstructural characterisation (through optical and scanning electron microscopy) and mechanical characterisation (tensile-strength tests) of the welded interface.

  13. Biomechanical evaluation of different instrumentation for spinal stabilisation.

    PubMed

    Graftiaux, A G; Wattier, B; Gentil, P; Mazel, C; Skalli, W; Diop, A; Kehr, P H; Lavaste, F

    1995-12-01

    The varying problems following arthrodesis of the lumbar spine with rods or plates (too much rigidity for the first and insufficient stability for the second) have led us to conceive another type of material, flexible but with enough stability, to favorise healing of bone graft, and decrease the induced pathology on adjacent levels. An experimental study of three types of material: rigid, semi-rigid and flexible was performed on eighteen fresh cadaver spinal segments without and then with discectomy and corporectomy to find out the various types of behaviour. The flexible device seems more supple than the other materials tested: more mobility, less stiffness. Rising hysteresis is explained by plastic deformation. The semi-rigid device presents strong osseous stresses on the L3 level and a large hysteresis corresponding most likely to a mobility between the screws and plates. The rigid device has less mobility, especially in torsion, ascribed to the transverse connection. The stability is high with a small hysteresis. This is of value for bone loss or instability with displacement of the vertebral body.The second study was a modeling of the flexible device validated by comparison to the experimental study. The strains in the wire were high, decreasing with increasing diameter, but is still lower than the elastic limit. The proximity of the elastic limit may allow plastic deformation of the wire. Howewer less strains were found on the screw fixation but increase with the increase diameter of the wire. The influence of the bone quality on the behavior of the device was demonstrated.

  14. Audio Motor Training at the Foot Level Improves Space Representation.

    PubMed

    Aggius-Vella, Elena; Campus, Claudio; Finocchietti, Sara; Gori, Monica

    2017-01-01

    Spatial representation is developed thanks to the integration of visual signals with the other senses. It has been shown that the lack of vision compromises the development of some spatial representations. In this study we tested the effect of a new rehabilitation device called ABBI (Audio Bracelet for Blind Interaction) to improve space representation. ABBI produces an audio feedback linked to body movement. Previous studies from our group showed that this device improves the spatial representation of space in early blind adults around the upper part of the body. Here we evaluate whether the audio motor feedback produced by ABBI can also improve audio spatial representation of sighted individuals in the space around the legs. Forty five blindfolded sighted subjects participated in the study, subdivided into three experimental groups. An audio space localization (front-back discrimination) task was performed twice by all groups of subjects before and after different kind of training conditions. A group (experimental) performed an audio-motor training with the ABBI device placed on their foot. Another group (control) performed a free motor activity without audio feedback associated with body movement. The other group (control) passively listened to the ABBI sound moved at foot level by the experimenter without producing any body movement. Results showed that only the experimental group, which performed the training with the audio-motor feedback, showed an improvement in accuracy for sound discrimination. No improvement was observed for the two control groups. These findings suggest that the audio-motor training with ABBI improves audio space perception also in the space around the legs in sighted individuals. This result provides important inputs for the rehabilitation of the space representations in the lower part of the body.

  15. Audio Motor Training at the Foot Level Improves Space Representation

    PubMed Central

    Aggius-Vella, Elena; Campus, Claudio; Finocchietti, Sara; Gori, Monica

    2017-01-01

    Spatial representation is developed thanks to the integration of visual signals with the other senses. It has been shown that the lack of vision compromises the development of some spatial representations. In this study we tested the effect of a new rehabilitation device called ABBI (Audio Bracelet for Blind Interaction) to improve space representation. ABBI produces an audio feedback linked to body movement. Previous studies from our group showed that this device improves the spatial representation of space in early blind adults around the upper part of the body. Here we evaluate whether the audio motor feedback produced by ABBI can also improve audio spatial representation of sighted individuals in the space around the legs. Forty five blindfolded sighted subjects participated in the study, subdivided into three experimental groups. An audio space localization (front-back discrimination) task was performed twice by all groups of subjects before and after different kind of training conditions. A group (experimental) performed an audio-motor training with the ABBI device placed on their foot. Another group (control) performed a free motor activity without audio feedback associated with body movement. The other group (control) passively listened to the ABBI sound moved at foot level by the experimenter without producing any body movement. Results showed that only the experimental group, which performed the training with the audio-motor feedback, showed an improvement in accuracy for sound discrimination. No improvement was observed for the two control groups. These findings suggest that the audio-motor training with ABBI improves audio space perception also in the space around the legs in sighted individuals. This result provides important inputs for the rehabilitation of the space representations in the lower part of the body. PMID:29326564

  16. Computational Fluid Dynamics and Experimental Characterization of the Pediatric Pump-Lung.

    PubMed

    Wu, Zhongjun J; Gellman, Barry; Zhang, Tao; Taskin, M Ertan; Dasse, Kurt A; Griffith, Bartley P

    2011-12-01

    The pediatric pump-lung (PediPL) is a miniaturized integrated pediatric pump-oxygenator specifically designed for cardiac or cardiopulmonary support for patients weighing 5-20 kg to allow mobility and extended use for 30 days. The PediPL incorporates a magnetically levitated impeller with uniquely configured hollow fiber membranes into a single unit capable of performing both pumping and gas exchange. A combined computational and experimental study was conducted to characterize the functional and hemocompatibility performances of this newly developed device. The three-dimensional flow features of the PediPL and its hemolytic characteristics were analyzed using computational fluid dynamics based modeling. The oxygen exchange was modeled based on a convection-diffusion-reaction process. The hollow fiber membranes were modeled as a porous medium which incorporates the flow resistance in the bundle by an added momentum sink term. The pumping function was evaluated for the required range of operating conditions (0.5-2.5 L/min and 1000-3000 rpm). The blood damage potentials were further analyzed in terms of flow and shear stress fields, and the calculations of hemolysis index. In parallel, the hydraulic pump performance, oxygen transfer and hemolysis level were quantified experimentally. Based on the computational and experimental results, the PediPL device is found to be functional to provide necessary oxygen transfer and blood pumping requirements for the pediatric patients. Smooth blood flow characteristics and low blood damage potential were observed in the entire device. The in-vitro tests further confirmed that the PediPL can provide adequate blood pumping and oxygen transfer over the range of intended operating conditions with acceptable hemolytic performance. The rated flow rate for oxygenation is 2.5 L/min. The normalized index of hemolysis is 0.065 g/100L at 1.0 L/min and 3000 rpm.

  17. Thermal Integration of a Liquid Acquisition Device into a Cryogenic Feed System

    NASA Technical Reports Server (NTRS)

    Hastings, L. J.; Bolshinskiy, L. G.; Schunk, R. G.; Martin, A. K.; Eskridge, R. H.; Frenkel, A.; Grayson, G.; Pendleton, M. L.

    2011-01-01

    Primary objectives of this effort were to define the following: (1) Approaches for quantification of the accumulation of thermal energy within a capillary screen liquid acquisition device (LAD) for a lunar lander upper stage during periods of up to 210 days on the lunar surface, (2) techniques for mitigating heat entrapment, and (3) perform initial testing, data evaluation. The technical effort was divided into the following categories: (1) Detailed thermal modeling of the LAD/feed system interactions using both COMSOL computational fluid device and standard codes, (2) FLOW-3D modeling of bulk liquid to provide interfacing conditions for the LAD thermal modeling, (3) condensation conditioning of capillary screens to stabilize surface tension retention capability, and (4) subscale testing of an integrated LAD/feed system. Substantial progress was achieved in the following technical areas: (1) Thermal modeling and experimental approaches for evaluating integrated cryogen LAD/feed systems, at both the system and component levels, (2) reduced gravity pressure control analyses, (3) analytical modeling and testing for capillary screen conditioning using condensation and wicking, and (4) development of rapid turnaround testing techniques for evaluating LAD/feed system thermal and fluid integration. A comprehensive effort, participants included a diverse cross section of representatives from academia, contractors, and multiple Marshall Space Flight Center organizations.

  18. Numerical evaluation of implantable hearing devices using a finite element model of human ear considering viscoelastic properties.

    PubMed

    Zhang, Jing; Tian, Jiabin; Ta, Na; Huang, Xinsheng; Rao, Zhushi

    2016-08-01

    Finite element method was employed in this study to analyze the change in performance of implantable hearing devices due to the consideration of soft tissues' viscoelasticity. An integrated finite element model of human ear including the external ear, middle ear and inner ear was first developed via reverse engineering and analyzed by acoustic-structure-fluid coupling. Viscoelastic properties of soft tissues in the middle ear were taken into consideration in this model. The model-derived dynamic responses including middle ear and cochlea functions showed a better agreement with experimental data at high frequencies above 3000 Hz than the Rayleigh-type damping. On this basis, a coupled finite element model consisting of the human ear and a piezoelectric actuator attached to the long process of incus was further constructed. Based on the electromechanical coupling analysis, equivalent sound pressure and power consumption of the actuator corresponding to viscoelasticity and Rayleigh damping were calculated using this model. The analytical results showed that the implant performance of the actuator evaluated using a finite element model considering viscoelastic properties gives a lower output above about 3 kHz than does Rayleigh damping model. Finite element model considering viscoelastic properties was more accurate to numerically evaluate implantable hearing devices. © IMechE 2016.

  19. A novel automatic regulatory device for continuous bladder irrigation based on wireless sensor in patients after transurethral resection of the prostate: A prospective investigation.

    PubMed

    Ding, Aimin; Cao, Huling; Wang, Lihua; Chen, Jiangang; Wang, Jian; He, Bosheng

    2016-12-01

    Benign prostatic hyperplasia is a common progressive disease in aging men, which leads to a significant impact on daily lives of patients. Continuous bladder irrigation (CBI) is a supplementary option for preventing the adverse events following transurethral resection of the prostate (TURP). Regulation of the flow rate based on the color of drainage bag is significant to prevent the clot formation and retention, which is controlled manually at present. To achieve a better control of flow rate and reduce inappropriate flow rate-related adverse effects, we designed an automatic flow rate controller for CBI applied with wireless sensor and evaluated its clinical efficacy. The therapeutic efficacy was evaluated in patients receiving the novel automatic bladder irrigation post-TURP in the experimental group compared with controls receiving traditional bladder irrigation in the control group. A total of 146 patients were randomly divided into 2 groups-the experimental group (n = 76) and the control group (n = 70). The mean irrigation volume of the experimental group (24.2 ± 3.8 L) was significantly lower than that of the controls (54.6 ± 5.4 L) (P < 0.05). Patients treated with automatic irrigation device had significantly decreased incidence of clot retention (8/76) and cystospasm (12/76) compared to controls (21/70; 39/70, P < 0.05). There was no significant difference between the 2 groups with regard to irrigation time (28.6 ± 2.7 vs 29.5 ± 3.4 hours, P = 0.077). The study suggests that the automatic regulating device applied with wireless sensor for CBI is safe and effective for patients after TURP. However, studies with a large population of patients and a long-term follow-up should be conducted to validate our findings.

  20. A novel automatic regulatory device for continuous bladder irrigation based on wireless sensor in patients after transurethral resection of the prostate

    PubMed Central

    Ding, Aimin; Cao, Huling; Wang, Lihua; Chen, Jiangang; Wang, Jian; He, Bosheng

    2016-01-01

    Abstract Background: Benign prostatic hyperplasia is a common progressive disease in aging men, which leads to a significant impact on daily lives of patients. Continuous bladder irrigation (CBI) is a supplementary option for preventing the adverse events following transurethral resection of the prostate (TURP). Regulation of the flow rate based on the color of drainage bag is significant to prevent the clot formation and retention, which is controlled manually at present. To achieve a better control of flow rate and reduce inappropriate flow rate–related adverse effects, we designed an automatic flow rate controller for CBI applied with wireless sensor and evaluated its clinical efficacy. Methods: The therapeutic efficacy was evaluated in patients receiving the novel automatic bladder irrigation post-TURP in the experimental group compared with controls receiving traditional bladder irrigation in the control group. Results: A total of 146 patients were randomly divided into 2 groups—the experimental group (n = 76) and the control group (n = 70). The mean irrigation volume of the experimental group (24.2 ± 3.8 L) was significantly lower than that of the controls (54.6 ± 5.4 L) (P < 0.05). Patients treated with automatic irrigation device had significantly decreased incidence of clot retention (8/76) and cystospasm (12/76) compared to controls (21/70; 39/70, P < 0.05). There was no significant difference between the 2 groups with regard to irrigation time (28.6 ± 2.7 vs 29.5 ± 3.4 hours, P = 0.077). Conclusion: The study suggests that the automatic regulating device applied with wireless sensor for CBI is safe and effective for patients after TURP. However, studies with a large population of patients and a long-term follow-up should be conducted to validate our findings. PMID:28033276

  1. Pulse Transit Time Measurement Using Seismocardiogram, Photoplethysmogram, and Acoustic Recordings: Evaluation and Comparison.

    PubMed

    Yang, Chenxi; Tavassolian, Negar

    2018-05-01

    This work proposes a novel method of pulse transit time (PTT) measurement. The proximal arterial location data are collected from seismocardiogram (SCG) recordings by placing a micro-electromechanical accelerometer on the chest wall. The distal arterial location data are recorded using an acoustic sensor placed inside the ear. The performance of distal location recordings is evaluated by comparing SCG-acoustic and SCG-photoplethysmogram (PPG) measurements. PPG and acoustic performances under motion noise are also compared. Experimental results suggest comparable performances for the acoustic-based and PPG-based devices. The feasibility of each PTT measurement method is validated for blood pressure evaluations and its limitations are analyzed.

  2. Introducing the pro-coagulant contact system in the numerical assessment of device-related thrombosis.

    PubMed

    Méndez Rojano, Rodrigo; Mendez, Simon; Nicoud, Franck

    2018-06-01

    Thrombosis is a major concern in blood-coated medical devices. Contact activation, which is the initial part of the coagulation cascade in device-related thrombosis, is not considered in current thrombus formation models. In the present study, pro-coagulant reactions including the contact activation system are coupled with a fluid solver in order to evaluate the potential of the contact system to initiate thrombin production. The biochemical/fluid model is applied to a backward-facing step configuration, a flow configuration that frequently appears in medical devices. In contrast to the in vivo thrombosis models in which a specific thrombotic zone (injury region) is set a priori by the user to initiate the coagulation reaction, a reactive surface boundary condition is applied to the whole device wall. Simulation results show large thrombin concentration in regions related to recirculation zones without the need of an a priori knowledge of the thrombus location. The numerical results align well with the regions prone to thrombosis observed in experimental results reported in the literature. This approach could complement thrombus formation models that take into account platelet activity and thrombus growth to optimize a wide range of medical devices.

  3. Radiotherapy and risk of implantable cardioverter-defibrillator malfunctions: experimental data from direct exposure at increasing doses.

    PubMed

    Zecchin, Massimo; Artico, Jessica; Morea, Gaetano; Severgnini, Mara; Bianco, Elisabetta; De Luca, Antonio; Fantasia, Anna Zorzin; Salvatore, Luca; Milan, Vittorino; Lucarelli, Matteo; Dissegna, Roberta; Cannatà, Antonio; Sinagra, Gianfranco

    2018-04-01

    During radiotherapy, in patients with implantable cardioverter-defibrillators (ICDs) malfunctions are considered more likely if doses more than 2 Gy reach the ICD site; however, most malfunctions occur with high-energy (>10 MV) radiations, and the risk is less defined using 6-MV linear accelerators. The purpose of the study is to experimentally evaluate the occurrence of malfunctions in ICDs radiated with a 6-MV linear accelerator at increasing photon doses. Thirty-two ICDs from all manufacturers (31 explanted and one demo) were evaluated; all devices with a sufficient battery charge underwent multiple radiations with a 6-MV photon beam reaching a cumulative dose at ICD site of 0.5, 1, 2, 3, 5 and 10 Gy and interrogated after every session. All antitachycardia therapies were left enabled; two ICDs were connected to a rhythm simulator (one simulating a complete atrioventricular block without ventricular activity) and visually monitored by external ECG and the ICD programmer during radiation. Thirteen ICDs were excluded before radiation because of battery depletion; after radiation up to the cumulative dose at the cardiac implantable electronic device site of 10 Gy, in the remaining 19 devices, programmation and battery charge remained unchanged and no switch to safety mode was observed; oversensing, pacing inhibition or inappropriate antitachycardia therapy were neither recorded nor visually observed during radiation. With a low-energy accelerator, neither malfunctions nor electromagnetic interferences were detected radiating the ICDs at doses usually reaching the ICD pocket during radiotherapy sessions. In this context, magnet application to avoid oversensing and inappropriate therapy seems, therefore, useless.

  4. Transsutural distraction osteogenesis applied to maxillary complex with new internalized distraction device: analysis of the feasibility and long-term osteogenesis outcome.

    PubMed

    Tong, Haizhou; Gao, Feng; Yin, Jiapeng; Zhang, Xiangyu; Zhang, Chen; Yin, Ningbei; Zhao, Zhenmin

    2015-03-01

    The purposes of this study were to evaluate the effects of transsutural distraction osteogenesis applied to the maxillary complex with a new internalized distraction device and to analyze the long-term osteogenesis outcome. Three-month-old beagle dogs were treated with a self-designed internalized distractor. The feasibility was evaluated, and the effects of the maxillary growth were measured using radiography and computed tomography (CT). The regenerated bone was examined with micro-CT, biomechanical testing, and histology 1 year after the distraction. The experimental group showed significantly larger forward displacement of maxillary during the distraction. One year after the distraction, the micro-CT showed more incompact structure and bone volume/total volume was significantly less in the experimental group. Biomechanical testing also showed a significantly lower yield but with no difference in stiffness. Histologic staining found osteoclasts deposited in the region of the suture and osteoblasts on the bone surface. The immunohistochemical staining of osteoprotegrin and receptor activator of nuclear factor-κ B ligand showed evidence of expression in suture area components and osteocytes with no difference between the groups. Transsutural distraction osteogenesis using an internalized distractor with skull anchorage demonstrated feasibility. It is expected that this device may provide new thoughts in developing an appropriate appliance for clinical use in young patients with midfacial hypoplasia. Moreover, the long-term osteogenesis analysis findings suggest that the metabolism of sutural area still remained active, which enhanced our understanding of bone remodeling in the sutural area to manage maxillary relapse after transsutural distraction osteogenesis.

  5. Effect of 3basic life support training programs in future primary school teachers. A quasi-experimental design.

    PubMed

    Navarro-Patón, R; Freire-Tellado, M; Basanta-Camiño, S; Barcala-Furelos, R; Arufe-Giraldez, V; Rodriguez-Fernández, J E

    2018-05-01

    To evaluate the learning of basic life support (BLS) measures on the part of laypersons after 3different teaching programs. A quasi-experimental before-after study involving a non-probabilistic sample without a control group was carried out. Primary school teacher students from the University of Santiago (Spain). A total of 124 students (68.8% women and 31.2% men) aged 20-39 years (M=22.23; SD=3.79), with no previous knowledge of BLS, were studied. Three teaching programs were used: a traditional course, an audio-visual approach and feedback devices. Chest compressions as sole cardiopulmonary resuscitation skill evaluation: average compression depth, compression rate, chest recoil percentage and percentage of correct compressions. Automated external defibrillator: time needed to apply a shock before and after the course. There were significant differences in the results obtained after 2minutes of chest compressions, depending on the training program received, with feedback devices having a clear advantage referred to average compression depth (p<0.001), compression rate (p<0.001), chest recoil percentage (p<0.001) and percentage of correct compressions (p<0.001). Regarding automated external defibrillator, statistically significant differences were found in T after (p=0.025). The teaching course using feedback devices obtained the best results in terms of the quality of chest compressions, followed by the traditional course and audio-visual approach. These favorable results were present in both men and women. All 3teaching methods reached the goal of reducing defibrillation time. Copyright © 2017 Elsevier España, S.L.U. y SEMICYUC. All rights reserved.

  6. Effects of estrogen on functional and neurological recovery after spinal cord injury: An experimental study with rats.

    PubMed

    Letaif, Olavo Biraghi; Cristante, Alexandre Fogaça; Barros Filho, Tarcísio Eloy Pessoa de; Ferreira, Ricardo; Santos, Gustavo Bispo dos; Rocha, Ivan Dias da; Marcon, Raphael Martus

    2015-10-01

    To evaluate the functional and histological effects of estrogen as a neuroprotective agent after a standard experimentally induced spinal cord lesion. In this experimental study, 20 male Wistar rats were divided into two groups: one group with rats undergoing spinal cord injury (SCI) at T10 and receiving estrogen therapy with 17-beta estradiol (4mg/kg) immediately following the injury and after the placement of skin sutures and a control group with rats only subjected to SCI. A moderate standard experimentally induced SCI was produced using a computerized device that dropped a weight on the rat's spine from a height of 12.5 mm. Functional recovery was verified with the Basso, Beattie and Bresnahan scale on the 2nd, 7th, 14th, 21st, 28th, 35th and 42nd days after injury and by quantifying the motor-evoked potential on the 42nd day after injury. Histopathological evaluation of the SCI area was performed after euthanasia on the 42nd day. The experimental group showed a significantly greater functional improvement from the 28th to the 42nd day of observation compared to the control group. The experimental group showed statistically significant improvements in the motor-evoked potential compared with the control group. The results of pathological histomorphometry evaluations showed a better neurological recovery in the experimental group, with respect to the proportion and diameter of the quantified nerve fibers. Estrogen administration provided benefits in neurological and functional motor recovery in rats with SCI beginning at the 28th day after injury.

  7. Effects of estrogen on functional and neurological recovery after spinal cord injury: An experimental study with rats

    PubMed Central

    Letaif, Olavo Biraghi; Cristante, Alexandre Fogaça; de Barros Filho, Tarcísio Eloy Pessoa; Ferreira, Ricardo; dos Santos, Gustavo Bispo; da Rocha, Ivan Dias; Marcon, Raphael Martus

    2015-01-01

    OBJECTIVES: To evaluate the functional and histological effects of estrogen as a neuroprotective agent after a standard experimentally induced spinal cord lesion. METHODS: In this experimental study, 20 male Wistar rats were divided into two groups: one group with rats undergoing spinal cord injury (SCI) at T10 and receiving estrogen therapy with 17-beta estradiol (4mg/kg) immediately following the injury and after the placement of skin sutures and a control group with rats only subjected to SCI. A moderate standard experimentally induced SCI was produced using a computerized device that dropped a weight on the rat's spine from a height of 12.5 mm. Functional recovery was verified with the Basso, Beattie and Bresnahan scale on the 2nd, 7th, 14th, 21st, 28th, 35th and 42nd days after injury and by quantifying the motor-evoked potential on the 42nd day after injury. Histopathological evaluation of the SCI area was performed after euthanasia on the 42nd day. RESULTS: The experimental group showed a significantly greater functional improvement from the 28th to the 42nd day of observation compared to the control group. The experimental group showed statistically significant improvements in the motor-evoked potential compared with the control group. The results of pathological histomorphometry evaluations showed a better neurological recovery in the experimental group, with respect to the proportion and diameter of the quantified nerve fibers. CONCLUSIONS: Estrogen administration provided benefits in neurological and functional motor recovery in rats with SCI beginning at the 28th day after injury. PMID:26598084

  8. A simplified design of the staggered herringbone micromixer for practical applications

    PubMed Central

    Du, Yan; Zhang, Zhiyi; Yim, ChaeHo; Lin, Min; Cao, Xudong

    2010-01-01

    We demonstrated a simple method for the device design of a staggered herringbone micromixer (SHM) using numerical simulation. By correlating the simulated concentrations with channel length, we obtained a series of concentration versus channel length profiles, and used mixing completion length Lm as the only parameter to evaluate the performance of device structure on mixing. Fluorescence quenching experiments were subsequently conducted to verify the optimized SHM structure for a specific application. Good agreement was found between the optimization and the experimental data. Since Lm is straightforward, easily defined and calculated parameter for characterization of mixing performance, this method for designing micromixers is simple and effective for practical applications. PMID:20697584

  9. A simplified design of the staggered herringbone micromixer for practical applications.

    PubMed

    Du, Yan; Zhang, Zhiyi; Yim, Chaeho; Lin, Min; Cao, Xudong

    2010-05-07

    We demonstrated a simple method for the device design of a staggered herringbone micromixer (SHM) using numerical simulation. By correlating the simulated concentrations with channel length, we obtained a series of concentration versus channel length profiles, and used mixing completion length L(m) as the only parameter to evaluate the performance of device structure on mixing. Fluorescence quenching experiments were subsequently conducted to verify the optimized SHM structure for a specific application. Good agreement was found between the optimization and the experimental data. Since L(m) is straightforward, easily defined and calculated parameter for characterization of mixing performance, this method for designing micromixers is simple and effective for practical applications.

  10. Simple and Sensitive Paper-Based Device Coupling Electrochemical Sample Pretreatment and Colorimetric Detection.

    PubMed

    Silva, Thalita G; de Araujo, William R; Muñoz, Rodrigo A A; Richter, Eduardo M; Santana, Mário H P; Coltro, Wendell K T; Paixão, Thiago R L C

    2016-05-17

    We report the development of a simple, portable, low-cost, high-throughput visual colorimetric paper-based analytical device for the detection of procaine in seized cocaine samples. The interference of most common cutting agents found in cocaine samples was verified, and a novel electrochemical approach was used for sample pretreatment in order to increase the selectivity. Under the optimized experimental conditions, a linear analytical curve was obtained for procaine concentrations ranging from 5 to 60 μmol L(-1), with a detection limit of 0.9 μmol L(-1). The accuracy of the proposed method was evaluated using seized cocaine samples and an addition and recovery protocol.

  11. Simulating of the measurement-device independent quantum key distribution with phase randomized general sources

    PubMed Central

    Wang, Qin; Wang, Xiang-Bin

    2014-01-01

    We present a model on the simulation of the measurement-device independent quantum key distribution (MDI-QKD) with phase randomized general sources. It can be used to predict experimental observations of a MDI-QKD with linear channel loss, simulating corresponding values for the gains, the error rates in different basis, and also the final key rates. Our model can be applicable to the MDI-QKDs with arbitrary probabilistic mixture of different photon states or using any coding schemes. Therefore, it is useful in characterizing and evaluating the performance of the MDI-QKD protocol, making it a valuable tool in studying the quantum key distributions. PMID:24728000

  12. Performance of quantum annealing on random Ising problems implemented using the D-Wave Two

    NASA Astrophysics Data System (ADS)

    Wang, Zhihui; Job, Joshua; Rønnow, Troels F.; Troyer, Matthias; Lidar, Daniel A.; USC Collaboration; ETH Collaboration

    2014-03-01

    Detecting a possible speedup of quantum annealing compared to classical algorithms is a pressing task in experimental adiabatic quantum computing. In this talk, we discuss the performance of the D-Wave Two quantum annealing device on Ising spin glass problems. The expected time to solution for the device to solve random instances with up to 503 spins and with specified coupling ranges is evaluated while carefully addressing the issue of statistical errors. We perform a systematic comparison of the expected time to solution between the D-Wave Two and classical stochastic solvers, specifically simulated annealing, and simulated quantum annealing based on quantum Monte Carlo, and discuss the question of speedup.

  13. A generic approach for examining the effectiveness of traffic control devices in school zones.

    PubMed

    Zhao, Xiaohua; Li, Jiahui; Ding, Han; Zhang, Guohui; Rong, Jian

    2015-09-01

    The effectiveness and performance of traffic control devices in school zones have been impacted significantly by many factors, such as driver behavioral attributes, roadway geometric features, environmental characteristics, weather and visibility conditions, region-wide traffic regulations and policies, control modes, etc. When deploying traffic control devices in school zones, efforts are needed to clarify: (1) whether traffic control device installation is warranted; and (2) whether other device effectively complements this traffic control device and strengthens its effectiveness. In this study, a generic approach is developed to examine and evaluate the effectiveness of various traffic control devices deployed in school zones through driving simulator-based experiments. A Traffic Control Device Selection Model (TCDSM) is developed and two representative school zones are selected as the testbed in Beijing for driving simulation implementation to enhance its applicability. Statistical analyses are conducted to extract the knowledge from test data recorded by a driving simulator. Multiple measures of effectiveness (MOEs) are developed and adopted including average speed, relative speed difference, and standard deviation of acceleration for traffic control device performance quantification. The experimental tests and analysis results reveal that the appropriateness of the installation of certain traffic control devices can be statistically verified by TCDSM. The proposed approach provides a generic framework to assess traffic control device performance in school zones including experiment design, statistical formulation, data analysis, simulation model implementation, data interpretation, and recommendation development. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. NATURAL GAS VARIABILITY IN CALIFORNIA: ENVIRONMENTAL IMPACTS AND DEVICE PERFORMANCE EXPERIMENTAL EVALUATION OF POLLUTANT EMISSIONS FROM RESIDENTIAL APPLIANCES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Singer, Brett C.; Apte, Michael G.; Black, Douglas R.

    2009-12-01

    The effect of liquefied natural gas on pollutant emissions was evaluated experimentally with used and new appliances in the laboratory and with appliances installed in residences, targeting information gaps from previous studies. Burner selection targeted available technologies that are projected to comprise the majority of installed appliances over the next decade. Experiments were conducted on 13 cooktop sets, 12 ovens, 5 broiler burners, 5 storage water heaters, 4 forced air furnaces, 1 wall furnace, and 6 tankless water heaters. Air-free concentrations and fuel-based emission factors were determined for carbon monoxide, nitrogen oxides, nitrogen dioxide, and the number of (predominantly ultrafine)more » particles over complete burns?including transient effects (device warm-up and intermittent firing of burners) following ignition--and during more stable end-of-burn conditions. Formaldehyde was measured over multi-burn cycles. The baseline fuel was Northern California line gas with Wobbe number (a measure of fuel energy delivery rate) of 1320-1340; test fuels had Wobbe numbers of roughly 1390 and 1420, and in some cases 1360. No ignition or operational problems were observed during test fuel use. Baseline emissions varied widely across and within burner groups and with burner operational mode. Statistically significant emissions changes were observed for some pollutants on some burners.« less

  15. Redundancy of stereoscopic images: Experimental evaluation

    NASA Astrophysics Data System (ADS)

    Yaroslavsky, L. P.; Campos, J.; Espínola, M.; Ideses, I.

    2005-12-01

    With the recent advancement in visualization devices over the last years, we are seeing a growing market for stereoscopic content. In order to convey 3D content by means of stereoscopic displays, one needs to transmit and display at least 2 points of view of the video content. This has profound implications on the resources required to transmit the content, as well as demands on the complexity of the visualization system. It is known that stereoscopic images are redundant which may prove useful for compression and may have positive effect on the construction of the visualization device. In this paper we describe an experimental evaluation of data redundancy in color stereoscopic images. In the experiments with computer generated and real life test stereo images, several observers visually tested the stereopsis threshold and accuracy of parallax measurement in anaglyphs and stereograms as functions of the blur degree of one of two stereo images. In addition, we tested the color saturation threshold in one of two stereo images for which full color 3D perception with no visible color degradations was maintained. The experiments support a theoretical estimate that one has to add, to data required to reproduce one of two stereoscopic images, only several percents of that amount of data in order to achieve stereoscopic perception.

  16. Preclinical Performance Evaluation of Percutaneous Glucose Biosensors: Experimental Considerations and Recommendations.

    PubMed

    Soto, Robert J; Schoenfisch, Mark H

    2015-06-17

    The utility of continuous glucose monitoring devices remains limited by an obstinate foreign body response (FBR) that degrades the analytical performance of the in vivo sensor. A number of novel materials that resist or delay the FBR have been proposed as outer, tissue-contacting glucose sensor membranes as a strategy to improve sensor accuracy. Traditionally, researchers have examined the ability of a material to minimize the host response by assessing adsorbed cell morphology and tissue histology. However, these techniques do not adequately predict in vivo glucose sensor function, necessitating sensor performance evaluation in a relevant animal model prior to human testing. Herein, the effects of critical experimental parameters, including the animal model and data processing methods, on the reliability and usefulness of preclinical sensor performance data are considered. © 2015 Diabetes Technology Society.

  17. Computational and experimental studies of LEBUs at high device Reynolds numbers

    NASA Technical Reports Server (NTRS)

    Bertelrud, Arild; Watson, R. D.

    1988-01-01

    The present paper summarizes computational and experimental studies for large-eddy breakup devices (LEBUs). LEBU optimization (using a computational approach considering compressibility, Reynolds number, and the unsteadiness of the flow) and experiments with LEBUs at high Reynolds numbers in flight are discussed. The measurements include streamwise as well as spanwise distributions of local skin friction. The unsteady flows around the LEBU devices and far downstream are characterized by strain-gage measurements on the devices and hot-wire readings downstream. Computations are made with available time-averaged and quasi-stationary techniques to find suitable device profiles with minimum drag.

  18. Human breath metabolomics using an optimized noninvasive exhaled breath condensate sampler

    PubMed Central

    Zamuruyev, Konstantin O.; Aksenov, Alexander A.; Pasamontes, Alberto; Brown, Joshua F.; Pettit, Dayna R.; Foutouhi, Soraya; Weimer, Bart C.; Schivo, Michael; Kenyon, Nicholas J.; Delplanque, Jean-Pierre; Davis, Cristina E.

    2017-01-01

    Exhaled breath condensate (EBC) analysis is a developing field with tremendous promise to advance personalized, non-invasive health diagnostics as new analytical instrumentation platforms and detection methods are developed. Multiple commercially-available and researcher-built experimental samplers are reported in the literature. However, there is very limited information available to determine an effective breath sampling approach, especially regarding the dependence of breath sample metabolomic content on the collection device design and sampling methodology. This lack of an optimal standard procedure results in a range of reported results that are sometimes contradictory. Here, we present a design of a portable human EBC sampler optimized for collection and preservation of the rich metabolomic content of breath. The performance of the engineered device is compared to two commercially available breath collection devices: the RTube™ and TurboDECCS. A number of design and performance parameters are considered, including: condenser temperature stability during sampling, collection efficiency, condenser material choice, and saliva contamination in the collected breath samples. The significance of the biological content of breath samples, collected with each device, is evaluated with a set of mass spectrometry methods and was the primary factor for evaluating device performance. The design includes an adjustable mass-size threshold for aerodynamic filtering of saliva droplets from the breath flow. Engineering an inexpensive device that allows efficient collection of metalomic-rich breath samples is intended to aid further advancement in the field of breath analysis for non-invasive health diagnostic. EBC sampling from human volunteers was performed under UC Davis IRB protocol 63701-3 (09/30/2014-07/07/2017). PMID:28004639

  19. Human breath metabolomics using an optimized non-invasive exhaled breath condensate sampler.

    PubMed

    Zamuruyev, Konstantin O; Aksenov, Alexander A; Pasamontes, Alberto; Brown, Joshua F; Pettit, Dayna R; Foutouhi, Soraya; Weimer, Bart C; Schivo, Michael; Kenyon, Nicholas J; Delplanque, Jean-Pierre; Davis, Cristina E

    2016-12-22

    Exhaled breath condensate (EBC) analysis is a developing field with tremendous promise to advance personalized, non-invasive health diagnostics as new analytical instrumentation platforms and detection methods are developed. Multiple commercially-available and researcher-built experimental samplers are reported in the literature. However, there is very limited information available to determine an effective breath sampling approach, especially regarding the dependence of breath sample metabolomic content on the collection device design and sampling methodology. This lack of an optimal standard procedure results in a range of reported results that are sometimes contradictory. Here, we present a design of a portable human EBC sampler optimized for collection and preservation of the rich metabolomic content of breath. The performance of the engineered device is compared to two commercially available breath collection devices: the RTube ™ and TurboDECCS. A number of design and performance parameters are considered, including: condenser temperature stability during sampling, collection efficiency, condenser material choice, and saliva contamination in the collected breath samples. The significance of the biological content of breath samples, collected with each device, is evaluated with a set of mass spectrometry methods and was the primary factor for evaluating device performance. The design includes an adjustable mass-size threshold for aerodynamic filtering of saliva droplets from the breath flow. Engineering an inexpensive device that allows efficient collection of metalomic-rich breath samples is intended to aid further advancement in the field of breath analysis for non-invasive health diagnostic. EBC sampling from human volunteers was performed under UC Davis IRB protocol 63701-3 (09/30/2014-07/07/2017).

  20. Effectiveness of a reusable low-cost balloon trocar dissection device in the creation of preperitoneal space during endoscopic surgery. An experimental study in swine.

    PubMed

    Nácul, Miguel Prestes; Cavazzola, Leandro Totti; Loureiro, Marcelo de Paula; Bonin, Eduardo Aimoré; Ferreira, Paulo Roberto Walter

    2015-09-01

    To evaluate a new, low-cost, reusable balloon trocar device for dissection of the preperitoneal space during endoscopic surgery. Twenty swine (weight: 15-37 kg) were randomized to two groups, according to whether the preperitoneal space was created with a new balloon device manufactured by Bhio-Supply (group B) or with the commercially available OMSPDB 1000® balloon device manufactured by Covidien (group C). Quality and size of the created preperitoneal space, identification of anatomic structures, balloon dissection time, total procedure time, balloon resistance and internal pressure after insufflation with 300 mL of ambient air, balloon-related complications, and procedure cost were assessed. No significant differences in dissection time, total procedure time, or size of the created preperitoneal space were found between the groups. Balloons in group B had a significantly higher internal pressure compared to balloons in group C. None of the balloons ruptured during the experiment. Three animals in group C had balloon-related peritoneal lacerations. Despite a higher individual device cost, group B had a lower procedure cost over the entire experiment. The new balloon device is not inferior to the commercially available device in terms of the safety and effectiveness for creating a preperitoneal space in swine.

  1. Percutaneous Transvenous Mitral Annuloplasty (PTMA) with the Viking device reduces pacing-induced mitral regurgitation.

    PubMed

    Kimblad, Per Ola; Harnek, Jan; Roijer, Anders; Meurling, Carl; Brandt, Johan; Solem, Jan Otto

    2005-11-01

    The new percutaneous mitral annuloplasty Viking device was evaluated in surviving sheep with pacing-induced mitral regurgitation. Twenty sheep were subjected to rapid ventricular pacing for one to three months, leading to cardiomyopathy and mitral regurgitation. Device implantation could be successfully performed in 11 of these animals after pacemaker treatment for 64+/-7 days. The device-related procedure time was 12+/-2 min. The mean follow-up time was 58+/-8 days after implantation of the device. Mitral annulus septo-lateral diameter was significantly reduced after insertion of the device, from 35+/-1 mm before implantation to 30+/-1 mm at the final follow up intracardiac echocardiography (P = 0.0097). The degree of mitral regurgitation (on a scale from 0 to 4) was 2.6+/-0.2 before device implantation and decreased to 0.8+/-0.2 after treatment (P = 0.0039), and the vena contracta was reduced from 7+/-0.4 mm to 3+/-0.8 mm (P = 0.0019). Angiography showed no signs of impairment of the coronary arteries. No thrombosis was observed. These results indicate that the septo-lateral diameter of the mitral annulus, and the degree of experimentally induced mitral regurgitation, can be significantly reduced with a percutaneous catheter technique in surviving sheep.

  2. Analytical and experimental procedures for determining propagation characteristics of millimeter-wave gallium arsenide microstrip lines

    NASA Technical Reports Server (NTRS)

    Romanofsky, Robert R.

    1989-01-01

    In this report, a thorough analytical procedure is developed for evaluating the frequency-dependent loss characteristics and effective permittivity of microstrip lines. The technique is based on the measured reflection coefficient of microstrip resonator pairs. Experimental data, including quality factor Q, effective relative permittivity, and fringing for 50-omega lines on gallium arsenide (GaAs) from 26.5 to 40.0 GHz are presented. The effects of an imperfect open circuit, coupling losses, and loading of the resonant frequency are considered. A cosine-tapered ridge-guide text fixture is described. It was found to be well suited to the device characterization.

  3. Histological evaluation of the influence of magnetic field application in autogenous bone grafts in rats

    PubMed Central

    Puricelli, Edela; Dutra, Nardier B; Ponzoni, Deise

    2009-01-01

    Background Bone grafts are widely used in oral and maxillofacial reconstruction. The influence of electromagnetic fields and magnets on the endogenous stimulation of target tissues has been investigated. This work aimed to assess the quality of bone healing in surgical cavities filled with autogenous bone grafts, under the influence of a permanent magnetic field produced by in vivo buried devices. Methods Metal devices consisting of commercially pure martensitic stainless steel washers and titanium screws were employed. Thirty male Wistar rats were divided into 3 experimental and 3 control groups. A surgical bone cavity was produced on the right femur, and a bone graft was collected and placed in each hole. Two metallic washers, magnetized in the experimental group but not in the control group, were attached on the borders of the cavity. Results The animals were sacrificed on postoperative days 15, 45 and 60. The histological analysis of control and experimental samples showed adequate integration of the bone grafts, with intense bone neoformation. On days 45 and 60, a continued influence of the magnetic field on the surgical cavity and on the bone graft was observed in samples from the experimental group. Conclusion The results showed intense bone neoformation in the experimental group as compared to control animals. The intense extra-cortical bone neoformation observed suggests that the osteoconductor condition of the graft may be more susceptible to stimulation, when submitted to a magnetic field. PMID:19134221

  4. The effect of incorporating different concentrations of chlorhexidine digluconate on the degree of conversion of an experimental adhesive resin.

    PubMed

    Moharam, Lamiaa-Mahmoud; Salem, Haidy-Nabil; Elgamily, Hanaa-Mahmoud

    2018-04-01

    The aim of this study was to evaluate the effect of chlorhexidine digluconate incorporation on the degree of conversion of an experimental adhesive resin. The experimental resin was prepared from 70 wt% bisphenol A glycerolate dimethacrylate, 30 wt% hydroxyethyl methacrylate, silanized SiO2 nanofillers, 0.5% of camphorquinone and ethyl 4-dimethylaminebenzoate (binary photo-initiator system). Five chlorhexidine digluconate concentrations (0, 0.5, 1, 2 and 4 wt%) were then incorporated into the experimental resin. Thirty Potassium Bromide pellets were prepared then divided into six groups (n=5/group), repre¬senting the tested adhesive resins (Single Bond 2, 0, 0.5, 1, 2 and 4 wt% chlohexidine-incorporated experimental adhesive resins), that were applied to the pellets without light-curing (uncured specimens). Another 30 pellets were prepared and treated with the previous materials then light-cured using LED light-curing device (cured specimens). Degree of conversion of the uncured and the cured specimens were evaluated using FTIR analysis. Adper Single Bond 2 showed the highest degree of conversion mean values followed by 0.5 wt% chlorhexidine concentration then 2 wt% followed by 4 wt% then 1 wt% concentrations, while 0 wt% concentration showed the lowest mean values. Chlorhexidine digluconate had slight significant influence on the efficiency of polymerization of the experimental adhesive resin. Key words: Chlorhexidine digluconate, different concentrations, degree of conversion, experimental adhesive resin.

  5. Experimental plasma research project summaries

    NASA Astrophysics Data System (ADS)

    1992-06-01

    This is the latest in a series of Project Summary books that date back to 1976. It is the first after a hiatus of several years. They are published to provide a short description of each project supported by the Experimental Plasma Research Branch of the Division of Applied Plasma Physics in the Office of Fusion Energy. The Experimental Plasma Research Branch seeks to provide a broad range of experimental data, physics understanding, and new experimental techniques that contribute to operation, interpretation, and improvement of high temperature plasma as a source of fusion energy. In pursuit of these objectives, the branch supports research at universities, DOE laboratories, other federal laboratories, and industry. About 70 percent of the funds expended are spent at universities and a significant function of this program is the training of students in fusion physics. The branch supports small- and medium-scale experimental studies directly related to specific critical plasma issues of the magnetic fusion program. Plasma physics experiments are conducted on transport of particles and energy within plasma. Additionally, innovative approaches for operating, controlling, and heating plasma are evaluated for application to the larger confinement devices of the magnetic fusion program. New diagnostic approaches to measuring the properties of high temperature plasmas are developed to the point where they can be applied with confidence on the large-scale confinement experiments. Atomic data necessary for impurity control, interpretation of diagnostic data, development of heating devices, and analysis of cooling by impurity ion radiation are obtained. The project summaries are grouped into the three categories of plasma physics, diagnostic development, and atomic physics.

  6. Ultrathin conformal devices for precise and continuous thermal characterization of human skin

    PubMed Central

    Webb, R. Chad; Bonifas, Andrew P.; Behnaz, Alex; Zhang, Yihui; Yu, Ki Jun; Cheng, Huanyu; Shi, Mingxing; Bian, Zuguang; Liu, Zhuangjian; Kim, Yun-Soung; Yeo, Woon-Hong; Park, Jae Suk; Song, Jizhou; Li, Yuhang; Huang, Yonggang; Gorbach, Alexander M.; Rogers, John A.

    2013-01-01

    Precision thermometry of the skin can, together with other measurements, provide clinically relevant information about cardiovascular health, cognitive state, malignancy and many other important aspects of human physiology. Here, we introduce an ultrathin, compliant skin-like sensor/actuator technology that can pliably laminate onto the epidermis to provide continuous, accurate thermal characterizations that are unavailable with other methods. Examples include non-invasive spatial mapping of skin temperature with millikelvin precision, and simultaneous quantitative assessment of tissue thermal conductivity. Such devices can also be implemented in ways that reveal the time-dynamic influence of blood flow and perfusion on these properties. Experimental and theoretical studies establish the underlying principles of operation, and define engineering guidelines for device design. Evaluation of subtle variations in skin temperature associated with mental activity, physical stimulation and vasoconstriction/dilation along with accurate determination of skin hydration through measurements of thermal conductivity represent some important operational examples. PMID:24037122

  7. Ultrathin conformal devices for precise and continuous thermal characterization of human skin

    NASA Astrophysics Data System (ADS)

    Webb, R. Chad; Bonifas, Andrew P.; Behnaz, Alex; Zhang, Yihui; Yu, Ki Jun; Cheng, Huanyu; Shi, Mingxing; Bian, Zuguang; Liu, Zhuangjian; Kim, Yun-Soung; Yeo, Woon-Hong; Park, Jae Suk; Song, Jizhou; Li, Yuhang; Huang, Yonggang; Gorbach, Alexander M.; Rogers, John A.

    2013-10-01

    Precision thermometry of the skin can, together with other measurements, provide clinically relevant information about cardiovascular health, cognitive state, malignancy and many other important aspects of human physiology. Here, we introduce an ultrathin, compliant skin-like sensor/actuator technology that can pliably laminate onto the epidermis to provide continuous, accurate thermal characterizations that are unavailable with other methods. Examples include non-invasive spatial mapping of skin temperature with millikelvin precision, and simultaneous quantitative assessment of tissue thermal conductivity. Such devices can also be implemented in ways that reveal the time-dynamic influence of blood flow and perfusion on these properties. Experimental and theoretical studies establish the underlying principles of operation, and define engineering guidelines for device design. Evaluation of subtle variations in skin temperature associated with mental activity, physical stimulation and vasoconstriction/dilation along with accurate determination of skin hydration through measurements of thermal conductivity represent some important operational examples.

  8. Charge transport properties of intrinsic layer in diamond vertical pin diode

    NASA Astrophysics Data System (ADS)

    Shimaoka, Takehiro; Kuwabara, Daisuke; Hara, Asuka; Makino, Toshiharu; Tanaka, Manobu; Koizumi, Satoshi

    2017-05-01

    Diamond is hoped to be utilized in ultimate power electronic devices exhibiting ultra-high blocking voltages. For practical device formation, it is important to characterize the electric properties to precisely simulate carrier transport and to practically design optimum device structures. In this study, we experimentally evaluated the charge transport properties of intrinsic layers in diamond vertical pin diodes using alpha-particle induced charge distribution measurements. The charge collection efficiencies were 98.1 ± 0.6% for a {111} pin diode and 96.9 ± 0.6% for a {100} pin diode, which means that almost all generated charges are collected accordingly equivalent to conventional Silicon pin photodiodes. Mobility-lifetime (μτ) products of holes were (2.2 ± 0.3) × 10-6 cm2/V for {111} and (1.8 ± 0.1) × 10-5 cm2/V for {100} diamond pin diodes.

  9. Thermal modeling of phase change solidification in thermal control devices including natural convection effects

    NASA Technical Reports Server (NTRS)

    Ukanwa, A. O.; Stermole, F. J.; Golden, J. O.

    1972-01-01

    Natural convection effects in phase change thermal control devices were studied. A mathematical model was developed to evaluate natural convection effects in a phase change test cell undergoing solidification. Although natural convection effects are minimized in flight spacecraft, all phase change devices are ground tested. The mathematical approach to the problem was to first develop a transient two-dimensional conduction heat transfer model for the solidification of a normal paraffin of finite geometry. Next, a transient two-dimensional model was developed for the solidification of the same paraffin by a combined conduction-natural-convection heat transfer model. Throughout the study, n-hexadecane (n-C16H34) was used as the phase-change material in both the theoretical and the experimental work. The models were based on the transient two-dimensional finite difference solutions of the energy, continuity, and momentum equations.

  10. Joint Services Electronics Program.

    DTIC Science & Technology

    1983-09-30

    environment. The research is under three interrelated heads: (1) algebraic Methodologies for Control Systems design , both linear and non -linear, (2) robust...properties of the device. After study of these experimental results, we plan to design a millimeter- wave version of the Gunn device. This will...appropriate dose discretization level for an adju- stable width beam. 2) Experimental Device Fabrication In a collaborative effort with the IC design group

  11. Experimental evaluation of an automated endoscope reprocessor with in situ generation of peracetic acid for disinfection of semicritical devices.

    PubMed

    Sattar, Syed A; Kibbee, Richard J; Tetro, Jason A; Rook, Tony A

    2006-11-01

    To evaluate the effectiveness of a high-level disinfection solution generated inside an endoscope processing system for decontaminating external and internal surfaces of experimentally contaminated heat-sensitive medical devices. The American Society for Testing and Materials Simulated-Use Test protocol (E1837-02), which incorporates a soil load in each inoculum, was used to evaluate the efficacy of the system when processing 4 common types of endoscopes contaminated separately with 5 types of nosocomial pathogens: Pseudomonas aeruginosa (ATCC 15442), spores of Clostridium difficile (ATCC 9689), a glutaraldehyde-resistant strain of Mycobacterium chelonae, a vancomycin-resistant strain of Enterococcus faecalis, and a methicillin-resistant strain of Staphylococcus aureus. Rinse solution samples from channels and from surfaces of the processed endoscopes were tested for any microbicidal residues. For all organisms tested, the baseline level of contamination of the endoscopes ranged from 5 log(10) to greater than 7 log(10) at each external surface site and internal channel. All tests showed reductions in viability of the test organisms to undetectable levels. All rinse solution samples from external and internal sites of the endoscopes proved to be free of any residual microbicidal activity. The endoscope reprocessor, with its processor-generated high-level disinfection solution, successfully reduced the numbers of selected, clinically relevant pathogens to undetectable levels both in the channels and on the outside surfaces of the 4 representative endoscopes tested in this study.

  12. Optical tests for using smartphones inside medical devices

    NASA Astrophysics Data System (ADS)

    Bernat, Amir S.; Acobas, Jennifer K.; Phang, Ye Shang; Hassan, David; Bolton, Frank J.; Levitz, David

    2018-02-01

    Smartphones are currently used in many medical applications and are more frequently being integrated into medical imaging devices. The regulatory requirements in existence today however, particularly the standardization of smartphone imaging through validation and verification testing, only partially cover imaging characteristics with a smartphone. Specifically, it has been shown that smartphone camera specifications are of sufficient quality for medical imaging, and there are devices which comply with the FDA's regulatory requirements for a medical device such as a device's field of view, direction of viewing and optical resolution and optical distortion. However, these regulatory requirements do not call specifically for color testing. Images of the same object using automatic settings or different light sources can show different color composition. Experimental results showing such differences are presented. Under some circumstances, such differences in color composition could potentially lead to incorrect diagnoses. It is therefore critical to control the smartphone camera and illumination parameters properly. This paper examines different smartphone camera settings that affect image quality and color composition. To test and select the correct settings, a test methodology is proposed. It aims at evaluating and testing image color correctness and white balance settings for mobile phones and LED light sources. Emphasis is placed on color consistency and deviation from gray values, specifically by evaluating the ΔC values based on the CIEL*a*b* color space. Results show that such standardization minimizes differences in color composition and thus could reduce the risk of a wrong diagnosis.

  13. Fracture resistance of retreated roots using different retreatment systems.

    PubMed

    Er, Kursat; Tasdemir, Tamer; Siso, Seyda Herguner; Celik, Davut; Cora, Sabri

    2011-08-01

    This study was designed to evaluate the fracture resistance of retreated roots using different rotary retreatment systems. Forty eight freshly extracted human canine teeth with single straight root canals were instrumented sequentially increasing from size 30 to a size 55 using K-files whit a stepback technique. The teeth were randomly divided into three experimental and one control groups of 12 specimens each. The root canals were filled using cold lateral compaction of gutta-percha and AH Plus (Dentsply Detrey, Konstanz, Germany) sealer in experimental groups. Removal of gutta-percha was performed with the following devices and techniques: ProTaper Universal (Dentsply Maillefer, Ballaigues, Switzerland), R-Endo (Micro-Mega, Besançon, France), and Mtwo (Sweden & Martina, Padova, Italy) rotary retreatment systems. Control group specimens were only instrumented, not filled or retreated. The specimens were then mounted in copper rings, were filled with a self-curing polymethylmethacrylate resin, and the force required to cause vertical root fracture was measured using a universal testing device. The force of fracture of the roots was recorded and the results in the various groups were compared. Statistical analysis was accomplished by one-way ANOVA and a post hoc Tukey tests. There were statistically significant differences between the control and experimental groups (P<.05). However, there were no significant differences among the experimental groups. Based on the results, all rotary retreatment techniques used in this in vitro study produced similar root weakness.

  14. A numerical performance assessment of a commercial cardiopulmonary by-pass blood heat exchanger.

    PubMed

    Consolo, Filippo; Fiore, Gianfranco B; Pelosi, Alessandra; Reggiani, Stefano; Redaelli, Alberto

    2015-06-01

    We developed a numerical model, based on multi-physics computational fluid dynamics (CFD) simulations, to assist the design process of a plastic hollow-fiber bundle blood heat exchanger (BHE) integrated within the INSPIRE(TM), a blood oxygenator (OXY) for cardiopulmonary by-pass procedures, recently released by Sorin Group Italia. In a comparative study, we analyzed five different geometrical design solutions of the BHE module. Quantitative geometrical-dependent parameters providing a comprehensive evaluation of both the hemo- and thermo-dynamics performance of the device were extracted to identify the best-performing prototypical solution. A convenient design configuration was identified, characterized by (i) a uniform blood flow pattern within the fiber bundle, preventing blood flow shunting and the onset of stagnation/recirculation areas and/or high velocity pathways, (ii) an enhanced blood heating efficiency, and (iii) a reduced blood pressure drop. The selected design configuration was then prototyped and tested to experimentally characterize the device performance. Experimental results confirmed numerical predictions, proving the effectiveness of CFD modeling as a reliable tool for in silico identification of suitable working conditions of blood handling medical devices. Notably, the numerical approach limited the need for extensive prototyping, thus reducing the corresponding machinery costs and time-to-market. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.

  15. Field studies of beach cones as coastal erosion control/reversal devices for areas with significant oil and gas activities. Technical progress report, April--June 1992 and Project status report, June 1992

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1992-07-17

    A field demonstration/study of a novel shoreline erosion protection device called beach cones is planned. These patented, fiberglass- reinforced concreted devices are to be deployed in a number of geometric patterns at seven location in the Bastian Bay area of Western Plaquemines Parish. The purpose of the work described in this report was to evaluate the proposed study`s impact on living and non-living shellfish resources within each of the project`s seven separate Study Areas. Major accomplishments for this reporting period were as follows: aerial photographs of the experimental sites were taken; all permit applications were filed; information was submitted formore » the Environmental Report; several reconnaissance trips to the experimental sites were made; meetings were held among all participating organizations to further plan the research; permit was obtained from the US Army Corps of Engineers; test sites were surveyed by the Xavier University contingent; survey data were taken at all sites; the Oyster Assessment was completed; permit was obtained from the State of Louisiana Department of Natural Resources; and initial survey data were finalized at all sites.« less

  16. Heat dissipation schemes in QCLs monitored by CCD thermoreflectance (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Pierscinski, Kamil; Pierścińska, Dorota; Morawiec, Magdalena; Gutowski, Piotr; Karbownik, Piotr; Serebrennikova, Olga; Bugajski, Maciej

    2017-02-01

    In this paper we present the development of the instrumentation for accurate evaluation of the thermal characteristics of quantum cascade lasers based on CCD thermoreflectance (CCD TR). This method allows rapid thermal characterization of QCLs, as the registration of high-resolution map of the whole device facet lasts only several seconds. The capabilities of the CCD TR are used to study temperature dissipation schemes in different designs of QCLs. We report on the investigation of thermal performance of QCLs developed at the Institute of Electron Technology, with an emphasis on the influence of different material system, processing technology and device designs. We investigate and compare AlInAs/InGaAs/InP QCLs (lattice matched and strain compensated) of different architectures, i.e., double trench and buried heterostructure (BH) in terms of thermal management. Experimental results are in very good agreement with numerical predictions of heat dissipation in various device constructions. Numerical model is based on FEM model solved by commercial software package. The model assumes anisotropic thermal conductivity in the AR layers as well as the temperature dependence of thermal conductivities of all materials in the project. We have observed experimentally improvement of thermal properties of devices based on InP materials, especially for buried heterostructure type. The use of buried heterostructure enhanced the lateral heat dissipation from the active region of QCLs. The BH structure and epilayer-down bonding help dissipate the heat generated from active core of the QCL.

  17. Numerical Modeling of Active Flow Control in a Boundary Layer Ingesting Offset Inlet

    NASA Technical Reports Server (NTRS)

    Allan, Brian G.; Owens, Lewis R.; Berrier, Bobby L.

    2004-01-01

    This investigation evaluates the numerical prediction of flow distortion and pressure recovery for a boundary layer ingesting offset inlet with active flow control devices. The numerical simulations are computed using a Reynolds averaged Navier-Stokes code developed at NASA. The numerical results are validated by comparison to experimental wind tunnel tests conducted at NASA Langley Research Center at both low and high Mach numbers. Baseline comparisons showed good agreement between numerical and experimental results. Numerical simulations for the inlet with passive and active flow control also showed good agreement at low Mach numbers where experimental data has already been acquired. Numerical simulations of the inlet at high Mach numbers with flow control jets showed an improvement of the flow distortion. Studies on the location of the jet actuators, for the high Mach number case, were conducted to provide guidance for the design of a future experimental wind tunnel test.

  18. [Research progress on mechanical performance evaluation of artificial intervertebral disc].

    PubMed

    Li, Rui; Wang, Song; Liao, Zhenhua; Liu, Weiqiang

    2018-03-01

    The mechanical properties of artificial intervertebral disc (AID) are related to long-term reliability of prosthesis. There are three testing methods involved in the mechanical performance evaluation of AID based on different tools: the testing method using mechanical simulator, in vitro specimen testing method and finite element analysis method. In this study, the testing standard, testing equipment and materials of AID were firstly introduced. Then, the present status of AID static mechanical properties test (static axial compression, static axial compression-shear), dynamic mechanical properties test (dynamic axial compression, dynamic axial compression-shear), creep and stress relaxation test, device pushout test, core pushout test, subsidence test, etc. were focused on. The experimental techniques using in vitro specimen testing method and testing results of available artificial discs were summarized. The experimental methods and research status of finite element analysis were also summarized. Finally, the research trends of AID mechanical performance evaluation were forecasted. The simulator, load, dynamic cycle, motion mode, specimen and test standard would be important research fields in the future.

  19. Evaluation of Home Health Care Devices: Remote Usability Assessment.

    PubMed

    Kortum, Philip; Peres, S Camille

    2015-06-05

    An increasing amount of health care is now performed in a home setting, away from the hospital. While there is growing anecdotal evidence about the difficulty patients and caregivers have using increasingly complex health care devices in the home, there has been little systematic scientific study to quantify the global nature of home health care device usability in the field. Research has tended to focus on a handful of devices, making it difficult to gain a broad view of the usability of home-care devices in general. The objective of this paper is to describe a remote usability assessment method using the System Usability Scale (SUS), and to report on the usability of a broad range of health care devices using this metric. A total of 271 participants selected and rated up to 10 home health care devices of their choice using the SUS, which scores usability from 0 (unusable) to 100 (highly usable). Participants rated a total of 455 devices in their own home without an experimenter present. Usability scores ranged from 98 (oxygen masks) to 59 (home hormone test kits). An analysis conducted on devices that had at least 10 ratings showed that the effect of device on SUS scores was significant (P<.001), and that the usability of these devices was on the low end when compared with other commonly used items in the home, such as microwave ovens and telephones. A large database of usability scores for home health care devices collected using this remote methodology would be beneficial for physicians, patients, and their caregivers.

  20. Chronic behavior evaluation of a micro-machined neural implant with optimized design based on an experimentally derived model.

    PubMed

    Andrei, Alexandru; Welkenhuysen, Marleen; Ameye, Lieveke; Nuttin, Bart; Eberle, Wolfgang

    2011-01-01

    Understanding the mechanical interactions between implants and the surrounding tissue is known to have an important role for improving the bio-compatibility of such devices. Using a recently developed model, a particular micro-machined neural implant design aiming the reduction of insertion forces dependence on the insertion speed was optimized. Implantations with 10 and 100 μm/s insertion speeds showed excellent agreement with the predicted behavior. Lesion size, gliosis (GFAP), inflammation (ED1) and neuronal cells density (NeuN) was evaluated after 6 week of chronic implantation showing no insertion speed dependence.

  1. Safety Assessment of Multi Purpose Small Payload Rack(MSPR)

    NASA Astrophysics Data System (ADS)

    Mizutani, Yoshinobu; Takada, Satomi; Murata, Kosei; Ozawa, Daisaku; Kobayashi, Ryoji; Nakamura, Yasuhiro

    2010-09-01

    We are reporting summary of preliminary safety assessment for Multi Purpose Small Payload Rack(MSPR), which is one of the micro gravity experiment facilities that are being developed for the 2nd phase JEM utilization(JEM: Japanese Experiment Module) that will be launched on H-II Transfer Vehicle(HTV) 2nd flight in 2011. MSPR is used for multi-purpose micro-g experiment providing experimental spaces and work stations. MSPR has three experimental spaces; first, there is a space called Work Volume(WV) with capacity volume of approximately 350 litters, in which multiple resources including electricity, communication, and moving image functions can be used. Within this space, installation of devices can be done by simple, prompt attachment by Velcro and pins with high degree of flexibility. Second, there is Small Experiment Area(SEA), with capacity volume of approximately 70 litters, in which electricity, communication, and moving image functions can also be used in the same way as WV. These spaces protect experiment devices and specimens from contingent loads by the crewmembers. Third, there is Work Bench with area of 0.5 square meters, on which can be used for maintenance, inspection and data operations of installed devices, etc. This bench can be stored in the rack during contingency. Chamber for Combustion Experiment(CCE) that is planned to be installed in WV is a pressure-resistant experimental container that can be used to seal hazardous materials from combustion experiments. This CCE has double sealing design in chamber itself, which resist gas leakage under normal the temperature and pressure. Electricity, communication, moving image function can be used in the same way as WV. JAXA Phase 2 Safety Review Panel(SRP) has been held in April, 2010. For safety analysis of MSPR, hazards were identified based on Fault Tree Analysis methodology and then these hazards were classified into either eight ISS standard-type hazards or eight unique-type hazards that requires special controls based on ISS common safety assessment methodology. Safety evaluation results are reported in the Safety Assessment Report(SAR) 1). Regarding structural failure, unique hazards are especially evaluated considering not only the tolerance for launch load but also load by crewmembers or orbital loads. Regarding electrical shock, electricity design up to secondary power is evaluated in unique hazard from a view point of Electrical design suitable for high voltage(32VDC or more) circuit. Regarding rupture/leakage of pressure system, hazards of fuel supply line, waste line for combustion gas, and pressure system including CCE are evaluated. Also evaluation for contamination due to hazardous gas leakage from CCE is conducted. External propagation of fire from CCE is also evaluated. In this report, we will show the overview of the result of safety assessment and future plan toward critical design phase activity.

  2. A System for Measurement of Convection Aboard Space Station

    NASA Technical Reports Server (NTRS)

    Bogatyrev, Gennady P.; Gorbunov, Aleksei V; Putin, Gennady F.; Ivanov, Alexander I.; Nikitin, Sergei A.; Polezhaev, Vadim I.

    1996-01-01

    A simple device for direct measurement of buoyancy driven fluid flows in a low-gravity environment is proposed. A system connecting spacecraft accelerometers data and results of thermal convection in enclosure measurements and numerical simulations is developed. This system will permit also to evaluate the low frequency microacceleration component. The goal of the paper is to present objectives and current results of ground-based experimental and numerical modeling of this convection detector.

  3. Air Force Engineering Research Initiation Grant Program

    DTIC Science & Technology

    1994-06-21

    MISFET Structures for High-Frequency Device Applications" RI-B-91-13 Prof. John W. Silvestro Clemson University "The Effect of Scattering by a Near...Synthesis Method for Concurrent Engineering Applications" RI-B-92-03 Prof. Steven H. Collicott Purdue University "An Experimental Study of the Effect of a ...beams is studied. The effect of interply delam- inations on natural frequencies and mode shapes is evaluated analytically. A generalized variational

  4. Standard Scenarios for the Less-Lethal Weapons Evaluation Model

    DTIC Science & Technology

    1975-08-01

    smoke (for obscuration) with chemical irritant. "MODIPAC" - 12 - gauge plastic shotgun shell loaded with polyethyleie shot. Net - A net for entrapment...Oklahoma, U. S. Department of Justice, April 30, 1974 (Grant Numbers 73-TA-08-0004 and 73-DF-06-0053). 12 Ana~lysis of Scenarios a. The developmecnt of...for transmitting electrical energy (e.g., TASER ). Electrical Prod - A device to transmit electrical shock to the target. Heavy Slug - Experimental

  5. Control of an ER haptic master in a virtual slave environment for minimally invasive surgery applications

    NASA Astrophysics Data System (ADS)

    Han, Young-Min; Choi, Seung-Bok

    2008-12-01

    This paper presents the control performance of an electrorheological (ER) fluid-based haptic master device connected to a virtual slave environment that can be used for minimally invasive surgery (MIS). An already developed haptic joint featuring controllable ER fluid and a spherical joint mechanism is adopted for the master system. Medical forceps and an angular position measuring device are devised and integrated with the joint to establish the MIS master system. In order to embody a human organ in virtual space, a volumetric deformable object is used. The virtual object is then mathematically formulated by a shape-retaining chain-linked (S-chain) model. After evaluating the reflection force, computation time and compatibility with real-time control, the haptic architecture for MIS is established by incorporating the virtual slave with the master device so that the reflection force for the object of the virtual slave and the desired position for the master operator are transferred to each other. In order to achieve the desired force trajectories, a sliding mode controller is formulated and then experimentally realized. Tracking control performances for various force trajectories are evaluated and presented in the time domain.

  6. Walking simulator for evaluation of ophthalmic devices

    NASA Astrophysics Data System (ADS)

    Barabas, James; Woods, Russell L.; Peli, Eli

    2005-03-01

    Simulating mobility tasks in a virtual environment reduces risk for research subjects, and allows for improved experimental control and measurement. We are currently using a simulated shopping mall environment (where subjects walk on a treadmill in front of a large projected video display) to evaluate a number of ophthalmic devices developed at the Schepens Eye Research Institute for people with vision impairment, particularly visual field defects. We have conducted experiments to study subject's perception of "safe passing distance" when walking towards stationary obstacles. The subject's binary responses about potential collisions are analyzed by fitting a psychometric function, which gives an estimate of the subject's perceived safe passing distance, and the variability of subject responses. The system also enables simulations of visual field defects using head and eye tracking, enabling better understanding of the impact of visual field loss. Technical infrastructure for our simulated walking environment includes a custom eye and head tracking system, a gait feedback system to adjust treadmill speed, and a handheld 3-D pointing device. Images are generated by a graphics workstation, which contains a model with photographs of storefronts from an actual shopping mall, where concurrent validation experiments are being conducted.

  7. Advanced high temperature static strain sensor development

    NASA Technical Reports Server (NTRS)

    Hulse, C. O.; Stetson, K. A.; Grant, H. P.; Jameikis, S. M.; Morey, W. W.; Raymondo, P.; Grudkowski, T. W.; Bailey, R. S.

    1986-01-01

    An examination was made into various techniques to be used to measure static strain in gas turbine liners at temperatures up to 1150 K (1600 F). The methods evaluated included thin film and wire resistive devices, optical fibers, surface acoustic waves, the laser speckle technique with a heterodyne readout, optical surface image and reflective approaches and capacitive devices. A preliminary experimental program to develop a thin film capacitive device was dropped because calculations showed that it would be too sensitive to thermal gradients. In a final evaluation program, the laser speckle technique appeared to work well up to 1150 K when it was used through a relatively stagnant air path. The surface guided acoustic wave approach appeared to be interesting but to require too much development effort for the funds available. Efforts to develop a FeCrAl resistive strain gage system were only partially successful and this part of the effort was finally reduced to a characterization study of the properties of the 25 micron diameter FeCrAl (Kanthal A-1) wire. It was concluded that this particular alloy was not suitable for use as the resistive element in a strain gage above about 1000 K.

  8. Advanced high temperature static strain sensor development

    NASA Astrophysics Data System (ADS)

    Hulse, C. O.; Stetson, K. A.; Grant, H. P.; Jameikis, S. M.; Morey, W. W.; Raymondo, P.; Grudkowski, T. W.; Bailey, R. S.

    1986-08-01

    An examination was made into various techniques to be used to measure static strain in gas turbine liners at temperatures up to 1150 K (1600 F). The methods evaluated included thin film and wire resistive devices, optical fibers, surface acoustic waves, the laser speckle technique with a heterodyne readout, optical surface image and reflective approaches and capacitive devices. A preliminary experimental program to develop a thin film capacitive device was dropped because calculations showed that it would be too sensitive to thermal gradients. In a final evaluation program, the laser speckle technique appeared to work well up to 1150 K when it was used through a relatively stagnant air path. The surface guided acoustic wave approach appeared to be interesting but to require too much development effort for the funds available. Efforts to develop a FeCrAl resistive strain gage system were only partially successful and this part of the effort was finally reduced to a characterization study of the properties of the 25 micron diameter FeCrAl (Kanthal A-1) wire. It was concluded that this particular alloy was not suitable for use as the resistive element in a strain gage above about 1000 K.

  9. Study of a Novel Oscillating Surge Wave Energy Converter: Preprint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tom, Nathan M; Choiniere, Michael; Thiagarajan, Krish P.

    This study investigates the performance of an oscillating surge wave energy converter (OSWEC) that utilizes adjustable geometry as a means of controlling the hydrodynamic coefficients, a concept originally proposed by [1]. The body of the device consists of a bottom-hinged solid rectangular frame with five horizontal flaps spanning the interior of the frame. The flaps can rotate independently about their center of rotation within the frame like a large window shutter. Changing the orientation of the flaps alters the hydrodynamic coefficients and natural frequency of the device as well as the ability to shed or absorb structural loads accordingly. Thismore » ability may allow the device to operate in a wider range of sea states than other current wave energy converter designs. This paper presents and compares the results of numerical simulations and experimental testing of the OSWEC's response to regular waves with all five of the horizontal fin configurations sharing the same orientation of 0 degrees (fully closed interior) and 90 degrees (fully open). The numerical simulations were performed using WAMIT, which calculates hydrodynamic coefficients using a boundary element method code to solve the linear potential flow problem, and WEC-Sim, a MATLAB-based tool that simulates multibody devices in the time domain by solving the governing equations of motion. A 1:14 scale model of the device was built for experimental evaluation in an 8-m-long, 1-m wide wave tank, which supports a water depth of 0.7 m. The OSWEC motion in different wave conditions was measured with displacement sensors while nonlinear wave-structure interaction effects like slamming and overtopping were captured using a high-speed camera and used to understand differences between the simulation and experiments.« less

  10. A comparative evaluation of polymerization stress data obtained with four different mechanical testing systems.

    PubMed

    Gonçalves, Flávia; Boaro, Leticia C; Ferracane, Jack L; Braga, Roberto R

    2012-06-01

    The null hypothesis was that mechanical testing systems used to determine polymerization stress (σ(pol)) would rank a series of composites similarly. Two series of composites were tested in the following systems: universal testing machine (UTM) using glass rods as bonding substrate, UTM/acrylic rods, "low compliance device", and single cantilever device ("Bioman"). One series had five experimental composites containing BisGMA:TEGDMA in equimolar concentrations and 60, 65, 70, 75 or 80 wt% of filler. The other series had five commercial composites: Filtek Z250 (3M ESPE), Filtek A110 (3M ESPE), Tetric Ceram (Ivoclar), Heliomolar (Ivoclar) and Point 4 (Kerr). Specimen geometry, dimensions and curing conditions were similar in all systems. σ(pol) was monitored for 10 min. Volumetric shrinkage (VS) was measured in a mercury dilatometer and elastic modulus (E) was determined by three-point bending. Shrinkage rate was used as a measure of reaction kinetics. ANOVA/Tukey test was performed for each variable, separately for each series. For the experimental composites, σ(pol) decreased with filler content in all systems, following the variation in VS. For commercial materials, σ(pol) did not vary in the UTM/acrylic system and showed very few similarities in rankings in the others tests system. Also, no clear relationships were observed between σ(pol) and VS or E. The testing systems showed a good agreement for the experimental composites, but very few similarities for the commercial composites. Therefore, comparison of polymerization stress results from different devices must be done carefully. Copyright © 2012 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  11. [Animal experimentation, computer simulation and surgical research].

    PubMed

    Carpentier, Alain

    2009-11-01

    We live in a digital world In medicine, computers are providing new tools for data collection, imaging, and treatment. During research and development of complex technologies and devices such as artificial hearts, computer simulation can provide more reliable information than experimentation on large animals. In these specific settings, animal experimentation should serve more to validate computer models of complex devices than to demonstrate their reliability.

  12. Improving Hall Thruster Plume Simulation through Refined Characterization of Near-field Plasma Properties

    NASA Astrophysics Data System (ADS)

    Huismann, Tyler D.

    Due to the rapidly expanding role of electric propulsion (EP) devices, it is important to evaluate their integration with other spacecraft systems. Specifically, EP device plumes can play a major role in spacecraft integration, and as such, accurate characterization of plume structure bears on mission success. This dissertation addresses issues related to accurate prediction of plume structure in a particular type of EP device, a Hall thruster. This is done in two ways: first, by coupling current plume simulation models with current models that simulate a Hall thruster's internal plasma behavior; second, by improving plume simulation models and thereby increasing physical fidelity. These methods are assessed by comparing simulated results to experimental measurements. Assessment indicates the two methods improve plume modeling capabilities significantly: using far-field ion current density as a metric, these approaches used in conjunction improve agreement with measurements by a factor of 2.5, as compared to previous methods. Based on comparison to experimental measurements, recent computational work on discharge chamber modeling has been largely successful in predicting properties of internal thruster plasmas. This model can provide detailed information on plasma properties at a variety of locations. Frequently, experimental data is not available at many locations that are of interest regarding computational models. Excepting the presence of experimental data, there are limited alternatives for scientifically determining plasma properties that are necessary as inputs into plume simulations. Therefore, this dissertation focuses on coupling current models that simulate internal thruster plasma behavior with plume simulation models. Further, recent experimental work on atom-ion interactions has provided a better understanding of particle collisions within plasmas. This experimental work is used to update collision models in a current plume simulation code. Previous versions of the code assume an unknown dependence between particles' pre-collision velocities and post-collision scattering angles. This dissertation focuses on updating several of these types of collisions by assuming a curve fit based on the measurements of atom-ion interactions, such that previously unknown angular dependences are well-characterized.

  13. Direct measurement of clinical mammographic x-ray spectra using a CdTe spectrometer.

    PubMed

    Santos, Josilene C; Tomal, Alessandra; Furquim, Tânia A; Fausto, Agnes M F; Nogueira, Maria S; Costa, Paulo R

    2017-07-01

    To introduce and evaluate a method developed for the direct measurement of mammographic x-ray spectra using a CdTe spectrometer. The assembly of a positioning system and the design of a simple and customized alignment device for this application is described. A positioning system was developed to easily and accurately locate the CdTe detector in the x-ray beam. Additionally, an alignment device to line up the detector with the central axis of the radiation beam was designed. Direct x-ray spectra measurements were performed in two different clinical mammography units and the measured x-ray spectra were compared with computer-generated spectra. In addition, the spectrometer misalignment effect was evaluated by comparing the measured spectra when this device is aligned relatively to when it is misaligned. The positioning and alignment of the spectrometer have allowed the measurements of direct mammographic x-ray spectra in agreement with computer-generated spectra. The most accurate x-ray spectral shape, related with the minimal HVL value, and high photon fluence for measured spectra was found with the spectrometer aligned according to the proposed method. The HVL values derived from both simulated and measured x-ray spectra differ at most 1.3 and 4.5% for two mammography devices evaluated in this study. The experimental method developed in this work allows simple positioning and alignment of a spectrometer for x-ray spectra measurements given the geometrical constraints and maintenance of the original configurations of mammography machines. © 2017 American Association of Physicists in Medicine.

  14. A framework for evaluating mixture analysis algorithms

    NASA Astrophysics Data System (ADS)

    Dasaratha, Sridhar; Vignesh, T. S.; Shanmukh, Sarat; Yarra, Malathi; Botonjic-Sehic, Edita; Grassi, James; Boudries, Hacene; Freeman, Ivan; Lee, Young K.; Sutherland, Scott

    2010-04-01

    In recent years, several sensing devices capable of identifying unknown chemical and biological substances have been commercialized. The success of these devices in analyzing real world samples is dependent on the ability of the on-board identification algorithm to de-convolve spectra of substances that are mixtures. To develop effective de-convolution algorithms, it is critical to characterize the relationship between the spectral features of a substance and its probability of detection within a mixture, as these features may be similar to or overlap with other substances in the mixture and in the library. While it has been recognized that these aspects pose challenges to mixture analysis, a systematic effort to quantify spectral characteristics and their impact, is generally lacking. In this paper, we propose metrics that can be used to quantify these spectral features. Some of these metrics, such as a modification of variance inflation factor, are derived from classical statistical measures used in regression diagnostics. We demonstrate that these metrics can be correlated to the accuracy of the substance's identification in a mixture. We also develop a framework for characterizing mixture analysis algorithms, using these metrics. Experimental results are then provided to show the application of this framework to the evaluation of various algorithms, including one that has been developed for a commercial device. The illustration is based on synthetic mixtures that are created from pure component Raman spectra measured on a portable device.

  15. Fabrication and characterization of SU-8-based capacitive micromachined ultrasonic transducer for airborne applications

    NASA Astrophysics Data System (ADS)

    Joseph, Jose; Singh, Shiv Govind; Vanjari, Siva Rama Krishna

    2018-01-01

    We present a successful fabrication and characterization of a capacitive micromachined ultrasonic transducer (CMUT) with SU-8 as the membrane material. The goal of this research is to develop a post-CMOS compatible CMUT that can be monolithically integrated with the CMOS circuitry. The fabrication is based on a simple, three mask process, with all wet etching steps involved so that the device can be realized with minimal laboratory conditions. The maximum temperature involved in the whole process flow was 140°C, and hence, it is post-CMOS compatible. The fabricated device exhibited a resonant frequency of 835 kHz with bandwidth 62 kHz, when characterized in air. The pull-in and snapback characteristics of the device were analyzed. The influence of membrane radius on the center frequency and bandwidth was also experimentally evaluated by fabricating CMUTs with membrane radius varying from 30 to 54 μm with an interval of 4 μm. These devices were vibrating at frequencies from 5.2 to 1.8 MHz with an average Q-factor of 23.41. Acoustic characterization of the fabricated devices was performed in air, demonstrating the applicability of SU-8 CMUTs in airborne applications.

  16. Calculus detection technologies: where do we stand now?

    PubMed Central

    Archana, V

    2014-01-01

    Epidemiological studies have implicated dental calculus as an ideal substrate for subgingival microbial colonization. Therefore, the main objective of periodontal therapy is to eliminate the microbial biofilm along with the calculus deposits from the root surface by root surface debridement. Over the past years, a large number of clinical and laboratory studies have been conducted to evaluate the efficacy of calculus removal by various methods. None of these conventional methods or devices was effective in completely eliminating all the calculus from the diseased root surfaces. In this context, a number of newer technologies have been developed to identify and selectively remove the dental calculus. Regarding this fact, the present article highlights a critical review of these devices based on published clinical and experimental data. PMID:25870667

  17. Design and evaluation of controls for drift, video gain, and color balance in spaceborne facsimile cameras

    NASA Technical Reports Server (NTRS)

    Katzberg, S. J.; Kelly, W. L., IV; Rowland, C. W.; Burcher, E. E.

    1973-01-01

    The facsimile camera is an optical-mechanical scanning device which has become an attractive candidate as an imaging system for planetary landers and rovers. This paper presents electronic techniques which permit the acquisition and reconstruction of high quality images with this device, even under varying lighting conditions. These techniques include a control for low frequency noise and drift, an automatic gain control, a pulse-duration light modulation scheme, and a relative spectral gain control. Taken together, these techniques allow the reconstruction of radiometrically accurate and properly balanced color images from facsimile camera video data. These techniques have been incorporated into a facsimile camera and reproduction system, and experimental results are presented for each technique and for the complete system.

  18. Calculus detection technologies: where do we stand now?

    PubMed

    Archana, V

    2014-01-01

    Epidemiological studies have implicated dental calculus as an ideal substrate for subgingival microbial colonization. Therefore, the main objective of periodontal therapy is to eliminate the microbial biofilm along with the calculus deposits from the root surface by root surface debridement. Over the past years, a large number of clinical and laboratory studies have been conducted to evaluate the efficacy of calculus removal by various methods. None of these conventional methods or devices was effective in completely eliminating all the calculus from the diseased root surfaces. In this context, a number of newer technologies have been developed to identify and selectively remove the dental calculus. Regarding this fact, the present article highlights a critical review of these devices based on published clinical and experimental data.

  19. Calibration procedure for a laser triangulation scanner with uncertainty evaluation

    NASA Astrophysics Data System (ADS)

    Genta, Gianfranco; Minetola, Paolo; Barbato, Giulio

    2016-11-01

    Most of low cost 3D scanning devices that are nowadays available on the market are sold without a user calibration procedure to correct measurement errors related to changes in environmental conditions. In addition, there is no specific international standard defining a procedure to check the performance of a 3D scanner along time. This paper aims at detailing a thorough methodology to calibrate a 3D scanner and assess its measurement uncertainty. The proposed procedure is based on the use of a reference ball plate and applied to a triangulation laser scanner. Experimental results show that the metrological performance of the instrument can be greatly improved by the application of the calibration procedure that corrects systematic errors and reduces the device's measurement uncertainty.

  20. Development of energy-harvesting system using deformation of magnetic elastomer

    NASA Astrophysics Data System (ADS)

    Shinoda, Hayato; Tsumori, Fujio

    2018-06-01

    In this paper, we propose a power generation method using the deformation of a magnetic elastomer for vibration energy harvesting. The magnetic flux lines in the structure of the magnetic elastomer could be markedly changed if the properly designed structure was expanded and contracted in a static magnetic field. We set a coil on the magnetic elastomer to generate electricity by capturing this change in magnetic flux flow. We fabricated a centimeter-scale device and demonstrated that it generated 10.5 mV of maximum voltage by 10 Hz vibration. We also simulated the change in the magnetic flux flow using finite element analysis, and compared the result with the experimental data. Furthermore, we evaluated the power generation of a miniaturized device.

  1. Effect of Vibration on Retention Characteristics of Screen Acquisition Systems

    NASA Technical Reports Server (NTRS)

    Tegart, J. R.; Park, A. C.

    1977-01-01

    An analytical and experimental investigation of the effect of vibration on the retention characteristics of screen acquisition systems was performed. The functioning of surface tension devices using fine-mesh screens requires that the pressure differential acting on the screen be less than its pressure retention capability. When exceeded, screen breakdown will occur and gas-free expulsion of propellant will no longer be possible. An analytical approach to predicting the effect of vibration was developed. This approach considers the transmission of the vibration to the screens of the device and the coupling of the liquid and the screen in establishing the screen response. A method of evaluating the transient response of the gas/liquid interface within the screen was also developed.

  2. Position paper: Management of men complaining of a small penis despite an actually normal size.

    PubMed

    Ghanem, Hussein; Glina, Sidney; Assalian, Pierre; Buvat, Jacques

    2013-01-01

    With the worldwide increase in penile augmentation procedures and claims of devices designed to elongate the penis, it becomes crucial to study the scientific basis of such procedures or devices, as well as the management of a complaint of a small penis in men with a normal penile size. The aim of this work is to study the scientific basis of opting to penile augmentation procedures and to develop guidelines based on the best available evidence for the management of men complaining of a small penis despite an actually normal size. We reviewed the literature and evaluated the evidence about what the normal penile size is, what patients complaining of a small penis usually suffer from, benefits vs. complications of surgery, penile stretching or traction devices, and outcome with patient education and counseling. Repeated presentation and detailed discussions within the Standard Committee of the International Society for Sexual Medicine were performed. Recommendations are based on the evaluation of evidence-based medical literature, widespread standards committee discussion, public presentation, and debate. We propose a practical approach for evaluating and counseling patients complaining of a small-sized penis. Based on the current status of science, penile lengthening procedure surgery is still considered experimental and should only be limited to special circumstances within research or university institutions with supervising ethics committees. © 2012 International Society for Sexual Medicine.

  3. Extremely low frequency (ELF) stray magnetic fields of laboratory equipment: a possible co-exposure conducting experiments on cell cultures.

    PubMed

    Gresits, Iván; Necz, Péter Pál; Jánossy, Gábor; Thuróczy, György

    2015-09-01

    Measurements of extremely low frequency (ELF) magnetic fields were conducted in the environment of commercial laboratory equipment in order to evaluate the possible co-exposure during the experimental processes on cell cultures. Three types of device were evaluated: a cell culture CO2 incubator, a thermostatic water bath and a laboratory shaker table. These devices usually have electric motors, heating wires and electronic control systems, therefore may expose the cell cultures to undesirable ELF stray magnetic fields. Spatial distributions of magnetic field time domain signal waveform and frequency spectral analysis (FFT) were processed. Long- and short-term variation of stray magnetic field was also evaluated under normal use of investigated laboratory devices. The results show that the equipment under test may add a considerable ELF magnetic field to the ambient environmental magnetic field or to the intentional exposure to ELF, RF or other physical/chemical agents. The maximum stray magnetic fields were higher than 3 µT, 20 µT and 75 µT in the CO2 incubator, in water bath and on the laboratory shaker table, respectively, with high variation of spatial distribution and time domain. Our investigation emphasizes possible confounding factors conducting cell culture studies related to low-level ELF-EMF exposure due to the existing stray magnetic fields in the ambient environment of laboratory equipment.

  4. Influence of the ambient temperature on the cooling efficiency of the high performance cooling device with thermosiphon effect

    NASA Astrophysics Data System (ADS)

    Nemec, Patrik; Malcho, Milan

    2018-06-01

    This work deal with experimental measurement and calculation cooling efficiency of the cooling device working with a heat pipe technology. The referred device in the article is cooling device capable transfer high heat fluxes from electric elements to the surrounding. The work contain description, working principle and construction of cooling device. The main factor affected the dissipation of high heat flux from electronic elements through the cooling device to the surrounding is condenser construction, its capacity and option of heat removal. Experimental part describe the measuring method cooling efficiency of the cooling device depending on ambient temperature in range -20 to 40°C and at heat load of electronic components 750 W. Measured results are compared with results calculation based on physical phenomena of boiling, condensation and natural convection heat transfer.

  5. Probing the low thermal conductivity of single-crystalline porous Si nanowires

    NASA Astrophysics Data System (ADS)

    Zhao, Yunshan; Lina Yang Collaboration; Lingyu Kong Collaboration; Baowen Li Collaboration; John T L Thong Collaboration; Kedar Hippalgaonkar Collaboration

    Pore-like structures provide a novel way to reduce the thermal conductivity of silicon nanowires, compared to both smooth-surface VLS nanowires and rough EE nanowires. Because of enhanced phonon scattering with interface and decrease in phonon transport path, the porous nanostructures show reduction in thermal conductance by few orders of magnitude. It proves to be extremely challenging to evaluate porosity accurately in an experimental manner and further understand its effect on thermal transport. In this study, we use the newly developed electron-beam based micro-electrothermal device technique to study the porosity dependent thermal conductivity of mesoporous silicon nanowires that have single-crystalline scaffolding. Based on the Casino simulation, the power absorbed by the nanowire, coming from the loss of travelling electron energy, has a linear relationship with it cross section. The relationship has been verified experimentally as well. Monte Carlo simulation is carried out to theoretically predict the thermal conductivity of silicon nanowires with a specific value of porosity. These single-crystalline porous silicon nanowires show extremely low thermal conductivity, even below the amorphous limit. These structures together with our experimental techniques provide a particularly intriguing platform to understand the phonon transport in nanoscale and aid the performance improvement in future nanowires-based devices.

  6. Experimental and numerical investigation of contact-area-limited doping for top-contact pentacene thin-film transistors with Schottky contact.

    PubMed

    Noda, Kei; Wada, Yasuo; Toyabe, Toru

    2015-10-28

    Effects of contact-area-limited doping for pentacene thin-film transistors with a bottom-gate, top-contact configuration were investigated. The increase in the drain current and the effective field-effect mobility was achieved by preparing hole-doped layers underneath the gold contact electrodes by coevaporation of pentacene and 2,3,5,6-tetrafluoro-7,7,8,8-tetracyanoquinodimethane (F4TCNQ), confirmed by using a thin-film organic transistor advanced simulator (TOTAS) incorporating Schottky contact with a thermionic field emission (TFE) model. Although the simulated electrical characteristics fit the experimental results well only in the linear regime of the transistor operation, the barrier height for hole injection and the gate-voltage-dependent hole mobility in the pentacene transistors were evaluated with the aid of the device simulation. This experimental data analysis with the simulation indicates that the highly-doped semiconducting layers prepared in the contact regions can enhance the charge carrier injection into the active semiconductor layer and concurrent trap filling in the transistor channel, caused by the mitigation of a Schottky energy barrier. This study suggests that both the contact-area-limited doping and the device simulation dealing with Schottky contact are indispensable in designing and developing high-performance organic thin-film transistors.

  7. [Effect of inspiratory muscle training on muscle strength and quality of life in patients with chronic airflow limitation: a randomized controlled trial].

    PubMed

    Serón, P; Riedemann, P; Muñoz, S; Doussoulin, A; Villarroel, P; Cea, X

    2005-11-01

    Chronic airflow limitation (CAL) is a significant cause of illness and death. Inspiratory muscle training has been described as a technique for managing CAL. The aim of the present study was to evaluate the effectiveness of inspiratory muscle training on improving physiological and functional variables. Randomized controlled trial in which 35 patients with CAL were assigned to receive either an experimental (n=17) or control (n=18) intervention. The experimental intervention consisted of 2 months of inspiratory muscle training using a device that administered a resistive load of 40% of maximal static inspiratory mouth pressure (PImax). Inspiratory muscle strength, exercise tolerance, respiratory function, and quality of life were assessed. Significant improvement in inspiratory muscle strength was observed in the experimental training group (P=.02). All patients improved over time in both groups (P<.001). PImax increased by 8.9 cm H2O per month of training. Likewise, the health-related quality of life scores improved by 0.56 points. Use of a threshold loading device is effective for strengthening inspiratory muscles as measured by PImax after the first month of training in patients with CAL. The long-term effectiveness of such training and its impact on quality of life should be studied in a larger number of patients.

  8. Experimental model of the device for detection of nuclear cycle materials by photoneutron technology

    NASA Astrophysics Data System (ADS)

    Bakalyarov, A. M.; Karetnikov, M. D.; Kozlov, K. N.; Lebedev, V. I.; Meleshko, E. A.; Obinyakov, B. A.; Ostashev, I. E.; Tupikin, N. A.; Yakovlev, G. V.

    2007-08-01

    The inherent complexity of sea container control makes them potentially dangerous for smuggling nuclear materials. The experts believe that only active technologies based on recording the products of induced radiation from sensitive materials might solve the problem. The paper reports on the experimental model of the device on the basis of the electron LINAC U-28 for detection of nuclear materials by photonuclear technology. The preliminary numerical optimization of output units (converter, filter, collimator) for shaping the bremsstrahlung was carried out. The setup of experimental device and initial results of recording the prompt and delayed fission products are discussed.

  9. Experimental Measurement-Device-Independent Entanglement Detection

    NASA Astrophysics Data System (ADS)

    Nawareg, Mohamed; Muhammad, Sadiq; Amselem, Elias; Bourennane, Mohamed

    2015-02-01

    Entanglement is one of the most puzzling features of quantum theory and of great importance for the new field of quantum information. The determination whether a given state is entangled or not is one of the most challenging open problems of the field. Here we report on the experimental demonstration of measurement-device-independent (MDI) entanglement detection using witness method for general two qubits photon polarization systems. In the MDI settings, there is no requirement to assume perfect implementations or neither to trust the measurement devices. This experimental demonstration can be generalized for the investigation of properties of quantum systems and for the realization of cryptography and communication protocols.

  10. Experimental Measurement-Device-Independent Entanglement Detection

    PubMed Central

    Nawareg, Mohamed; Muhammad, Sadiq; Amselem, Elias; Bourennane, Mohamed

    2015-01-01

    Entanglement is one of the most puzzling features of quantum theory and of great importance for the new field of quantum information. The determination whether a given state is entangled or not is one of the most challenging open problems of the field. Here we report on the experimental demonstration of measurement-device-independent (MDI) entanglement detection using witness method for general two qubits photon polarization systems. In the MDI settings, there is no requirement to assume perfect implementations or neither to trust the measurement devices. This experimental demonstration can be generalized for the investigation of properties of quantum systems and for the realization of cryptography and communication protocols. PMID:25649664

  11. Evaluation of canine red blood cell quality after processing with an automated cell salvage device.

    PubMed

    Hofbauer, Nina; Windberger, Ursula; Schwendenwein, Ilse; Tichy, Alexander; Eberspächer, Eva

    2016-05-01

    To evaluate the properties of RBC concentrate harvested after processing fresh whole blood units from healthy dogs with an automated cell salvage device. Prospective, in vitro, experimental study. University teaching hospital. Sixteen healthy, privately owned dogs of various breeds. Fresh canine whole blood collected in bags with citrate phosphate dextrose adenine solution was processed with an automated cell salvage device and analyzed in vitro. Laboratory values determined before (baseline, from a catheter sample) and after processing RBCs (procRBCs) included a complete blood count, selected blood chemistry analytes, erythrocyte osmotic resistance, whole blood viscosity, RBC aggregation, and RBC deformability. Total recovery of RBCs was 80% ± 12%. Hematocrit of the procRBCs yielded by the device was 77% ± 3.7% (mean ± standard deviation). Gross morphology of the RBCs remained unchanged. The mean corpuscular volume, erythrocyte osmotic resistance, RBC deformability, RBC aggregation, and the activity of lactate dehydrogenase showed minor but statistically significant changes from baseline. No differences in the concentrations of free hemoglobin were observed. Whole blood viscosity was less in the procRBCs. Seventy-seven percent (mean) of the platelets were washed out, while a mean of 57% of the leukocytes remained in the procRBCs. Although processing canine blood with this automated cell salvage device leads to slight changes in some properties of RBCs, most of these changes are comparable to changes seen in human blood after processing. Present data indicate that the use of this cell salvage device does not induce changes in canine RBC concentrate that would preclude its use for transfusion. © Veterinary Emergency and Critical Care Society 2016.

  12. Quality factor of luminescent solar concentrators and practical concentration limits attainable with semiconductor quantum dots

    DOE PAGES

    Klimov, Victor I.; Baker, Thomas A.; Lim, Jaehoon; ...

    2016-05-09

    In this study, luminescent solar concentrators (LSCs) can be utilized as both large-area collectors of solar radiation supplementing traditional photovoltaic cells as well as semitransparent “solar windows” that provide a desired degree of shading and simultaneously serve as power-generation units. An important characteristic of an LSC is a concentration factor (C) that can be thought of as a coefficient of effective enlargement (or contraction) of the area of a solar cell when it is coupled to the LSC. Here we use analytical and numerical Monte Carlo modeling in addition to experimental studies of quantum-dot-based LSCs to analyze the factors thatmore » influence optical concentration in practical devices. Our theoretical model indicates that the maximum value of C achievable with a given fluorophore is directly linked to the LSC quality factor (Q LSC) defined as the ratio of absorption coefficients at the wavelengths of incident and reemitted light. In fact, we demonstrate that the ultimate concentration limit (C 0) realized in large-area devices scales linearly with the LSC quality factor and in the case of perfect emitters and devices without back reflectors is approximately equal to Q LSC. To test the predictions of this model, we conduct experimental studies of LSCs based on visible-light emitting II–VI core/shell quantum dots with two distinct LSC quality factors. We also investigate devices based on near-infrared emitting CuInSe xS 2–x quantum dots for which the large emission bandwidth allows us to assess the impact of varied Q LSC on the concentration factor by simply varying the detection wavelength. In all cases, we find an excellent agreement between the model and the experimental observations, suggesting that the developed formalism can be utilized for express evaluation of prospective LSC performance based on the optical spectra of LSC fluorophores, which should facilitate future efforts on the development of high-performance devices based on quantum dots as well as other types of emitters.« less

  13. Quality factor of luminescent solar concentrators and practical concentration limits attainable with semiconductor quantum dots

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Klimov, Victor I.; Baker, Thomas A.; Lim, Jaehoon

    In this study, luminescent solar concentrators (LSCs) can be utilized as both large-area collectors of solar radiation supplementing traditional photovoltaic cells as well as semitransparent “solar windows” that provide a desired degree of shading and simultaneously serve as power-generation units. An important characteristic of an LSC is a concentration factor (C) that can be thought of as a coefficient of effective enlargement (or contraction) of the area of a solar cell when it is coupled to the LSC. Here we use analytical and numerical Monte Carlo modeling in addition to experimental studies of quantum-dot-based LSCs to analyze the factors thatmore » influence optical concentration in practical devices. Our theoretical model indicates that the maximum value of C achievable with a given fluorophore is directly linked to the LSC quality factor (Q LSC) defined as the ratio of absorption coefficients at the wavelengths of incident and reemitted light. In fact, we demonstrate that the ultimate concentration limit (C 0) realized in large-area devices scales linearly with the LSC quality factor and in the case of perfect emitters and devices without back reflectors is approximately equal to Q LSC. To test the predictions of this model, we conduct experimental studies of LSCs based on visible-light emitting II–VI core/shell quantum dots with two distinct LSC quality factors. We also investigate devices based on near-infrared emitting CuInSe xS 2–x quantum dots for which the large emission bandwidth allows us to assess the impact of varied Q LSC on the concentration factor by simply varying the detection wavelength. In all cases, we find an excellent agreement between the model and the experimental observations, suggesting that the developed formalism can be utilized for express evaluation of prospective LSC performance based on the optical spectra of LSC fluorophores, which should facilitate future efforts on the development of high-performance devices based on quantum dots as well as other types of emitters.« less

  14. Impact of Device Scaling on Deep Sub-micron Transistor Reliability: A Study of Reliability Trends using SRAM

    NASA Technical Reports Server (NTRS)

    White, Mark; Huang, Bing; Qin, Jin; Gur, Zvi; Talmor, Michael; Chen, Yuan; Heidecker, Jason; Nguyen, Duc; Bernstein, Joseph

    2005-01-01

    As microelectronics are scaled in to the deep sub-micron regime, users of advanced technology CMOS, particularly in high-reliability applications, should reassess how scaling effects impact long-term reliability. An experimental based reliability study of industrial grade SRAMs, consisting of three different technology nodes, is proposed to substantiate current acceleration models for temperature and voltage life-stress relationships. This reliability study utilizes step-stress techniques to evaluate memory technologies (0.25mum, 0.15mum, and 0.13mum) embedded in many of today's high-reliability space/aerospace applications. Two acceleration modeling approaches are presented to relate experimental FIT calculations to Mfr's qualification data.

  15. Shaking table experimentation on adjacent structures controlled by passive and semi-active MR dampers

    NASA Astrophysics Data System (ADS)

    Basili, M.; De Angelis, M.; Fraraccio, G.

    2013-06-01

    This paper presents the results of shaking table tests on adjacent structures controlled by passive and semi-active MR dampers. The aim was to demonstrate experimentally the effectiveness of passive and semi-active strategies in reducing structural vibrations due to seismic excitation. The physical model at issue was represented by two adjacent steel structures, respectively of 4 and 2 levels, connected at the second level by a MR damper. When the device operated in semi-active mode, an ON-OFF control algorithm, derived by the Lyapunov stability theory, was implemented and experimentally validated. Since the experimentation concerned adjacent structures, two control objectives have been reached: global and selective protection. In case of global protection, the attention was focused on protecting both structures, whereas, in case of selective protection, the attention was focused on protecting only one structure. For each objective the effectiveness of passive control has been compared with the situation of no control and then the effectiveness of semi-active control has been compared with the passive one. The quantities directly compared have been: measured displacements, accelerations and force-displacement of the MR damper, moreover some global response quantities have been estimated from experimental measures, which are the base share force and the base bending moment, the input energy and the energy dissipated by the device. In order to evaluate the effectiveness of the control action in both passive and semi-active case, an energy index EDI, previously defined and already often applied numerically, has been utilized. The aspects investigated in the experimentation have been: the implementation and validation of the control algorithm for selective and global protection, the MR damper input voltage influence, the kind of seismic input and its intensity.

  16. Pilot Wave Model for Impulsive Thrust from RF Test Device Measured in Vacuum

    NASA Technical Reports Server (NTRS)

    White, Harold; Lawrence, James; Sylvester, Andre; Vera, Jerry; Chap, Andrew; George, Jeff

    2017-01-01

    A physics model is developed in detail and its place in the taxonomy of ideas about the nature of the quantum vacuum is discussed. The experimental results from the recently completed vacuum test campaign evaluating the impulsive thrust performance of a tapered RF test article excited in the TM212 mode at 1,937 megahertz (MHz) are summarized. The empirical data from this campaign is compared to the predictions from the physics model tools. A discussion is provided to further elaborate on the possible implications of the proposed model if it is physically valid. Based on the correlation of analysis prediction with experimental data collected, it is proposed that the observed anomalous thrust forces are real, not due to experimental error, and are due to a new type of interaction with quantum vacuum fluctuations.

  17. A new device-independent dimension witness and its experimental implementation

    NASA Astrophysics Data System (ADS)

    Cai, Yu; Bancal, Jean-Daniel; Romero, Jacquiline; Scarani, Valerio

    2016-07-01

    A dimension witness is a criterion that sets a lower bound on the dimension needed to reproduce the observed data. Three types of dimension witnesses can be found in the literature: device-dependent ones, in which the bound is obtained assuming some knowledge on the state and the measurements; device-independent prepare-and-measure ones, that can be applied to any system including classical ones; and device-independent Bell-based ones, that certify the minimal dimension of some entangled systems. Here we consider the Collins-Gisin-Linden-Massar-Popescu Bell-type inequality for four outcomes. We show that a sufficiently high violation of this inequality witnesses d≥slant 4 and present a proof-of-principle experimental observation of such a violation. This presents a first experimental violation of the third type of dimension witness beyond qutrits.

  18. Atomically resolved tissue integration.

    PubMed

    Karlsson, Johan; Sundell, Gustav; Thuvander, Mattias; Andersson, Martin

    2014-08-13

    In the field of biomedical technology, a critical aspect is the ability to control and understand the integration of an implantable device in living tissue. Despite the technical advances in the development of biomaterials, the elaborate interplay encompassing materials science and biology on the atomic level is not very well understood. Within implantology, anchoring a biomaterial device into bone tissue is termed osseointegration. In the most accepted theory, osseointegration is defined as an interfacial bonding between implant and bone; however, there is lack of experimental evidence to confirm this. Here we show that atom probe tomography can be used to study the implant-tissue interaction, allowing for three-dimensional atomic mapping of the interface region. Interestingly, our analyses demonstrated that direct contact between Ca atoms and the implanted titanium oxide surface is formed without the presence of a protein interlayer, which means that a pure inorganic interface is created, hence giving experimental support to the current theory of osseointegration. We foresee that this result will be of importance in the development of future biomaterials as well as in the design of in vitro evaluation techniques.

  19. The effects of topical oxygen therapy on equine distal limb dermal wound healing.

    PubMed

    Tracey, Alexandra K; Alcott, Cody J; Schleining, Jennifer A; Safayi, Sina; Zaback, Peter C; Hostetter, Jesse M; Reinertson, Eric L

    2014-12-01

    Topical oxygen therapy (TOT) has been used in human medicine to promote healing in chronic wounds. To test the efficacy and safety of TOT in horses, an experimental wound model was created by making 1 standardized dermal wound on each limb of 4 healthy horses (n = 16). Each wound was fitted with an oxygen delivery cannula and covered with a bandage. One limb of each front and hind pair was randomly assigned to the treatment group (fitted with an oxygen concentrator device), with the contralateral limb assigned to the control group (no device). Wound area, epithelial area, and contraction were measured every 3 to 4 d. Biopsy samples and culture swabs were taken on days 16 and 32 to evaluate angiogenesis, fibroplasia, epithelial hyperplasia, inflammation and bacterial growth. Mean healing time in treated wounds (45 d, range: 38 to 52 d) was not significantly different from that in the paired control wounds (50 d, range: 38 to 62 d). Topical oxygen therapy had little effect on dermal wound healing in this experimental wound model in healthy horses.

  20. Experimental and Analytic Evaluation of the Effects of Visual and Motion Simulation in SH-3 Helicopter Training. Technical Report 85-002.

    ERIC Educational Resources Information Center

    Pfeiffer, Mark G.; Scott, Paul G.

    A fly-only group (N=16) of Navy replacement pilots undergoing fleet readiness training in the SH-3 helicopter was compared with groups pre-trained on Device 2F64C with: (1) visual only (N=13); (2) no visual/no motion (N=14); and (3) one visual plus motion group (N=19). Groups were compared for their SH-3 helicopter performance in the transition…

  1. Summary of Research, Academic Departments, 1982-1983.

    DTIC Science & Technology

    1983-10-01

    Office to pursue fur- - and the production of towing tank models is de - ther proof of concept tests and seek improvements ,’ scribed. The design...followed b" Haskind. Rci,,ncr. * as "Cable Fire Studies: Progress Report in Evaluation of Timman, van de Vooren and Greidanus. and Release Rate Apparatus...diameter of the in the capture chamber have been compared with a system is increased, the draft of the device is de - limited amount of experimental data

  2. Study of switching transients in high frequency converters

    NASA Technical Reports Server (NTRS)

    Zinger, Donald S.; Elbuluk, Malik E.; Lee, Tony

    1993-01-01

    As the semiconductor technologies progress rapidly, the power densities and switching frequencies of many power devices are improved. With the existing technology, high frequency power systems become possible. Use of such a system is advantageous in many aspects. A high frequency ac source is used as the direct input to an ac/ac pulse-density-modulation (PDM) converter. This converter is a new concept which employs zero voltage switching techniques. However, the development of this converter is still in its infancy stage. There are problems associated with this converter such as a high on-voltage drop, switching transients, and zero-crossing detecting. Considering these problems, the switching speed and power handling capabilities of the MOS-Controlled Thyristor (MCT) makes the device the most promising candidate for this application. A complete insight of component considerations for building an ac/ac PDM converter for a high frequency power system is addressed. A power device review is first presented. The ac/ac PDM converter requires switches that can conduct bi-directional current and block bi-directional voltage. These bi-directional switches can be constructed using existing power devices. Different bi-directional switches for the converter are investigated. Detailed experimental studies of the characteristics of the MCT under hard switching and zero-voltage switching are also presented. One disadvantage of an ac/ac converter is that turn-on and turn-off of the switches has to be completed instantaneously when the ac source is at zero voltage. Otherwise shoot-through current or voltage spikes can occur which can be hazardous to the devices. In order for the devices to switch softly in the safe operating area even under non-ideal cases, a unique snubber circuit is used in each bi-directional switch. Detailed theory and experimental results for circuits using these snubbers are presented. A current regulated ac/ac PDM converter built using MCT's and IGBT's is evaluated.

  3. MEASUREMENT OF PHONON TRANSPORT IN GaN-ON-SiC AND GaN-ON-DIAMOND HIGH ELECTRON MOBILITY TRANSISTOR (HEMT) DEVICES

    DTIC Science & Technology

    2017-10-16

    DARPA) or the U.S. Government. Report contains color. 14. ABSTRACT The objective of this project is to experimentally study the transient non ...the Metal Thin Film in TDTR ........................................ 14 4.3 Experimental Observation of the Frequency Filtering Effect...scale of the device layers and the high density of interfaces, non -diffusive heat conduction plays a critical role in thermal transport of GaN devices

  4. Poor chest compression quality with mechanical compressions in simulated cardiopulmonary resuscitation: a randomized, cross-over manikin study.

    PubMed

    Blomberg, Hans; Gedeborg, Rolf; Berglund, Lars; Karlsten, Rolf; Johansson, Jakob

    2011-10-01

    Mechanical chest compression devices are being implemented as an aid in cardiopulmonary resuscitation (CPR), despite lack of evidence of improved outcome. This manikin study evaluates the CPR-performance of ambulance crews, who had a mechanical chest compression device implemented in their routine clinical practice 8 months previously. The objectives were to evaluate time to first defibrillation, no-flow time, and estimate the quality of compressions. The performance of 21 ambulance crews (ambulance nurse and emergency medical technician) with the authorization to perform advanced life support was studied in an experimental, randomized cross-over study in a manikin setup. Each crew performed two identical CPR scenarios, with and without the aid of the mechanical compression device LUCAS. A computerized manikin was used for data sampling. There were no substantial differences in time to first defibrillation or no-flow time until first defibrillation. However, the fraction of adequate compressions in relation to total compressions was remarkably low in LUCAS-CPR (58%) compared to manual CPR (88%) (95% confidence interval for the difference: 13-50%). Only 12 out of the 21 ambulance crews (57%) applied the mandatory stabilization strap on the LUCAS device. The use of a mechanical compression aid was not associated with substantial differences in time to first defibrillation or no-flow time in the early phase of CPR. However, constant but poor chest compressions due to failure in recognizing and correcting a malposition of the device may counteract a potential benefit of mechanical chest compressions. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  5. Experimental studies of MOS inversion and accumulation layers: Quantum mechanical effects and mobility

    NASA Astrophysics Data System (ADS)

    Chindalore, Gowrishankar L.

    The development of fast, multi-functional, and energy efficient integrated circuits, is made possible by aggressively scaling the gate lengths of the MOS devices into the sub-quarter micron regime. However, with the increasing cost of fabrication, there is a strong need for the development of reliable and accurate device simulation capabilities. The development of the theoretical models for simulators is guided by extensive experimental data, which enable an experimental verification of the models, and lead to a better understanding of the underlying physics. This dissertation presents the methodology and the results for one such experimental effort, where two important physical effects in the inversion layer and the accumulation layer of a MOS device, namely, the quantum mechanical (QM) effects and the carrier mobility are investigated. Accordingly, this dissertation has been divided into two parts, with the first part discussing the increase in the threshold voltage and the accumulation electrical oxide thickness due to QM effects. The second part discusses the methodology and the experimental results for the extraction of the majority carrier mobilities in the accumulation layers of a MOSFET. The continued scaling of the MOS gate length requires decreased gate oxide thickness (tox) and increased channel doping (NB) in order to improve device performance while suppressing the short- channel effects. The combination of the two result in large enough transverse electric fields to cause significant quantization of the carriers in the potential well at the Si/SiO2 interface. Hence, compared to the classical calculations (where the QM effects are ignored), the QM effects are found to lead to an increase in the experimental threshold voltage by approximately 100mV, and an overestimation of the physical oxide thickness by approximately 3-4A, in MOSFET devices with a gate oxide thickness and the doping level anticipated for technologies with sub-quarter micron gate lengths. Thus, the experimental results indicate the need for using accurate QM models for simulating sub-quarter micron devices. Carrier mobility is a fundamental semiconductor device transport parameter that has been extensively characterized for both electrons and holes in the silicon bulk and MOS inversion layers. Accumulation layer mobility (μacc) has become increasingly important as the MOS devices have scaled to deep submicron gate lengths, and much effort has been required to achieve increased drive current. However, very little experimental data has been reported for carrier mobility in the MOS accumulation layers (Sun80, Man89). Hence, in this research work, the accumulation layer mobilities were extracted using buried-channel MOSFETs for both the electrons and holes, and for a wide range of doping levels at temperatures ranging from 25C to 150C. The experimental μacc is found to be greater than the corresponding bulk and the inversion layer mobilities, at low to moderate effective fields. However, at very high effective fields, where phonon and surface roughness scattering are dominant, the mobility behavior is found to be very similar to that of the inversion carriers. The extensive set of experimental data will enable the development of accurate local accumulation mobility models for inclusion in 2-D device simulators.

  6. Echographic detectability of optoacoustic signals from low-concentration PEG-coated gold nanorods

    PubMed Central

    Conversano, Francesco; Soloperto, Giulia; Greco, Antonio; Ragusa, Andrea; Casciaro, Ernesto; Chiriacò, Fernanda; Demitri, Christian; Gigli, Giuseppe; Maffezzoli, Alfonso; Casciaro, Sergio

    2012-01-01

    Purpose: To evaluate the diagnostic performance of gold nanorod (GNR)-enhanced optoacoustic imaging employing a conventional echographic device and to determine the most effective operative configuration in order to assure optoacoustic effectiveness, nanoparticle stability, and imaging procedure safety. Methods: The most suitable laser parameters were experimentally determined in order to assure nanoparticle stability during the optoacoustic imaging procedures. The selected configuration was then applied to a novel tissue-mimicking phantom, in which GNR solutions covering a wide range of low concentrations (25–200 pM) and different sample volumes (50–200 μL) were exposed to pulsed laser irradiation. GNR-emitted optoacoustic signals were acquired either by a couple of single-element ultrasound probes or by an echographic transducer. Off-line analysis included: (a) quantitative evaluation of the relationships between GNR concentration, sample volume, phantom geometry, and amplitude of optoacoustic signals propagating along different directions; (b) echographic detection of “optoacoustic spots,” analyzing their intensity, spatial distribution, and clinical exploitability. MTT measurements performed on two different cell lines were also used to quantify biocompatibility of the synthesized GNRs in the adopted doses. Results: Laser irradiation at 30 mJ/cm2 for 20 seconds resulted in the best compromise among the requirements of effectiveness, safety, and nanoparticle stability. Amplitude of GNR-emitted optoacoustic pulses was proportional to both sample volume and concentration along each considered propagation direction for all the tested boundary conditions, providing an experimental confirmation of isotropic optoacoustic emission. Average intensity of echographically detected spots showed similar behavior, emphasizing the presence of an “ideal” GNR concentration (100 pM) that optimized optoacoustic effectiveness. The tested GNRs also exhibited high biocompatibility over the entire considered concentration range. Conclusion: An optimal configuration for GNR-enhanced optoacoustic imaging was experimentally determined, demonstrating in particular its feasibility with a conventional echographic device. The proposed approach can be easily extended to quantitative performance evaluation of different contrast agents for optoacoustic imaging. PMID:22927756

  7. A System for the Measurement of the Subjective Visual Vertical using a Virtual Reality Device.

    PubMed

    Negrillo-Cárdenas, José; Rueda-Ruiz, Antonio J; Ogayar-Anguita, Carlos J; Lomas-Vega, Rafael; Segura-Sánchez, Rafael J

    2018-05-31

    The Subjective Visual Vertical (SVV) is a common test for evaluating the perception of verticality. Altered verticality has been connected with disorders in the otolithic, visual or proprioceptive systems, caused by stroke, Parkinson's disease or multiple sclerosis, among others. Currently, this test is carried out using a variety of specific, mostly homemade apparatuses that include moving planes, buckets, hemispheric domes or a line projected in a screen. Our aim is to develop a flexible, inexpensive, user-friendly and easily extensible system based on virtual reality for the measurement of the SVV and several related visual diagnostic tests, and validate it through an experimental evaluation. Two different hardware configurations were tested with 50 healthy volunteers in a controlled environment; 28 of them were males and 22 females, with ages ranging from 18 to 49 years, being 23 the average age. The Intraclass Correlation Coefficient (ICC) was computed in each device. In addition, a usability survey was conducted. ICC = 0.85 in the first configuration (CI = 0.75-0.92), ICC = 0.76 in the second configuration (CI = 0.61-0.87), both with 95% of confidence, which means a substantial reliability. Moreover, 92.2% of subjects rated the usability of the system as "very good". Our evaluation showed that the proposed system is suitable for the measurement of SVV in healthy subjects. The next step is to perform a more elaborated experimentation on patients and compare the results with the measurements obtained from traditional methods.

  8. Instrumented Compliant Wrist with Proximity and Contact Sensing for Close Robot Interaction Control.

    PubMed

    Laferrière, Pascal; Payeur, Pierre

    2017-06-14

    Compliance has been exploited in various forms in robotic systems to allow rigid mechanisms to come into contact with fragile objects, or with complex shapes that cannot be accurately modeled. Force feedback control has been the classical approach for providing compliance in robotic systems. However, by integrating other forms of instrumentation with compliance into a single device, it is possible to extend close monitoring of nearby objects before and after contact occurs. As a result, safer and smoother robot control can be achieved both while approaching and while touching surfaces. This paper presents the design and extensive experimental evaluation of a versatile, lightweight, and low-cost instrumented compliant wrist mechanism which can be mounted on any rigid robotic manipulator in order to introduce a layer of compliance while providing the controller with extra sensing signals during close interaction with an object's surface. Arrays of embedded range sensors provide real-time measurements on the position and orientation of surfaces, either located in proximity or in contact with the robot's end-effector, which permits close guidance of its operation. Calibration procedures are formulated to overcome inter-sensor variability and achieve the highest available resolution. A versatile solution is created by embedding all signal processing, while wireless transmission connects the device to any industrial robot's controller to support path control. Experimental work demonstrates the device's physical compliance as well as the stability and accuracy of the device outputs. Primary applications of the proposed instrumented compliant wrist include smooth surface following in manufacturing, inspection, and safe human-robot interaction.

  9. Development of Personalized Fitting Device With 3-Dimensional Solution for Prevention of NIV Oronasal Mask-Related Pressure Ulcers.

    PubMed

    Shikama, Maiko; Nakagami, Gojiro; Noguchi, Hiroshi; Mori, Taketoshi; Sanada, Hiromi

    2018-05-22

    Pressure ulcers related to oronasal masks used with noninvasive ventilation (NIV), along with patient discomfort, occur due to improper fit of the mask. We developed a personalized fitting device using a 3-dimensional (3D) scanning solution to prevent the formation of NIV mask-related pressure ulcers. This study aimed to evaluate the effectiveness of the proposed personalized fitting device. We conducted a randomized crossover experimental study of 20 healthy participants to study the use of this personalized fitting device between the face and an NIV mask designed with 3D solutions. The fitting device was not used under the NIV mask for the control. The outcome measures were the presence of blanchable erythema, standardized redness intensity, discomfort level, and contact pressure. The incidence of blanchable erythema and standardized redness intensity values were significantly lower for subjects who used the fitting device when worn for 30 min ( P < .001). The discomfort levels at the forehead, nasal bridge, and both cheeks, as well as leakage, were significantly reduced as well ( P = .008, P < .001, P = .001, P = .002, P = .001, P = .02, P < .001, P < .001, P < .001). Contact pressure at the nasal bridge, where pressure ulcers most frequently develop, was significantly decreased with the fitting device ( P < .001). Personalized fitting devices that incorporate 3D scanning solutions may contribute to the prevention of NIV mask-related pressure ulcers and the reduction of discomfort. Copyright © 2018 by Daedalus Enterprises.

  10. Fracture Resistance of Retreated Roots Using Different Retreatment Systems

    PubMed Central

    Er, Kursat; Tasdemir, Tamer; Siso, Seyda Herguner; Celik, Davut; Cora, Sabri

    2011-01-01

    Objectives: This study was designed to evaluate the fracture resistance of retreated roots using different rotary retreatment systems. Methods: Forty eight freshly extracted human canine teeth with single straight root canals were instrumented sequentially increasing from size 30 to a size 55 using K-files whit a stepback technique. The teeth were randomly divided into three experimental and one control groups of 12 specimens each. The root canals were filled using cold lateral compaction of gutta-percha and AH Plus (Dentsply Detrey, Konstanz, Germany) sealer in experimental groups. Removal of gutta-percha was performed with the following devices and techniques: ProTaper Universal (Dentsply Maillefer, Ballaigues, Switzerland), R-Endo (Micro-Mega, Besançon, France), and Mtwo (Sweden & Martina, Padova, Italy) rotary retreatment systems. Control group specimens were only instrumented, not filled or retreated. The specimens were then mounted in copper rings, were filled with a self-curing polymethylmethacrylate resin, and the force required to cause vertical root fracture was measured using a universal testing device. The force of fracture of the roots was recorded and the results in the various groups were compared. Statistical analysis was accomplished by one-way ANOVA and a post hoc Tukey tests. Results: There were statistically significant differences between the control and experimental groups (P<.05). However, there were no significant differences among the experimental groups. Conclusions: Based on the results, all rotary retreatment techniques used in this in vitro study produced similar root weakness. PMID:21912497

  11. Charge collection and SEU mechanisms

    NASA Astrophysics Data System (ADS)

    Musseau, O.

    1994-01-01

    In the interaction of cosmic ions with microelectronic devices a dense electron-hole plasma is created along the ion track. Carriers are separated and transported by the electric field and under the action of the concentration gradient. The subsequent collection of these carriers induces a transient current at some electrical node of the device. This "ionocurrent" (single ion induced current) acts as any electrical perturbation in the device, propagating in the circuit and inducing failures. In bistable systems (registers, memories) the stored data can be upset. In clocked devices (microprocessors) the parasitic perturbation may propagate through the device to the outputs. This type of failure only effects the information, and do not degrade the functionally of the device. The purpose of this paper is to review the mechanisms of single event upset in microelectronic devices. Experimental and theoretical results are presented, and actual questions and problems are discussed. A brief introduction recalls the creation of the dense plasma of electron-hole pairs. The basic processes for charge collection in a simple np junction (drift and diffusion) are presented. The funneling-field effect is discussed and experimental results are compared to numerical simulations and semi-empirical models. Charge collection in actual microelectronic structures is then presented. Due to the parasitic elements, coupling effects are observed. Geometrical effects, in densely packed structures, results in multiple errors. Electronic couplings are due to the carriers in excess, acting as minority carriers, that trigger parasitic bipolar transistors. Single event upset of memory cells is discussed, based on numerical and experimental data. The main parameters for device characterization are presented. From the physical interpretation of charge collection mechanisms, the intrinsic sensitivity of various microelectronic technologies is determined and compared to experimental data. Scaling laws and future trends are finally discussed.

  12. Quasi-Isentropic Compressibility of Deuterium at a Pressure of 12 TPa

    NASA Astrophysics Data System (ADS)

    Mochalov, M. A.; Il'kaev, R. I.; Fortov, V. E.; Mikhailov, A. L.; Arinin, V. A.; Blikov, A. O.; Komrakov, V. A.; Maksimkin, I. P.; Ogorodnikov, V. A.; Ryzhkov, A. V.

    2018-04-01

    An experimental result for the quasi-isentropic compressibility of a strongly nonideal deuterium plasma compressed in a spherical device by the pressure P = 11400 GPa (114 Mbar) to the density ρ ≈ 10g/cm3 has been reported. The characteristics of the experimental device, diagnostic methods, and experimental results have been described. The trajectory of motion of metallic shells compressing a deuterium plasma has been recorded using intense pulsed sources of X rays with the boundary energy of electrons up to 60 MeV. The deuterium plasma density ρ ≈ 10g/cm3 has been determined from the measured radius of the shell at the time of its "stop." The pressure of the compressed plasma has been determined from gas-dynamic calculations taking into account the real characteristics of the experimental device.

  13. Prediction of Phase Behavior of Spray-Dried Amorphous Solid Dispersions: Assessment of Thermodynamic Models, Standard Screening Methods and a Novel Atomization Screening Device with Regard to Prediction Accuracy

    PubMed Central

    Chavez, Pierre-François; Meeus, Joke; Robin, Florent; Schubert, Martin Alexander; Somville, Pascal

    2018-01-01

    The evaluation of drug–polymer miscibility in the early phase of drug development is essential to ensure successful amorphous solid dispersion (ASD) manufacturing. This work investigates the comparison of thermodynamic models, conventional experimental screening methods (solvent casting, quench cooling), and a novel atomization screening device based on their ability to predict drug–polymer miscibility, solid state properties (Tg value and width), and adequate polymer selection during the development of spray-dried amorphous solid dispersions (SDASDs). Binary ASDs of four drugs and seven polymers were produced at 20:80, 40:60, 60:40, and 80:20 (w/w). Samples were systematically analyzed using modulated differential scanning calorimetry (mDSC) and X-ray powder diffraction (XRPD). Principal component analysis (PCA) was used to qualitatively assess the predictability of screening methods with regards to SDASD development. Poor correlation was found between theoretical models and experimentally-obtained results. Additionally, the limited ability of usual screening methods to predict the miscibility of SDASDs did not guarantee the appropriate selection of lead excipient for the manufacturing of robust SDASDs. Contrary to standard approaches, our novel screening device allowed the selection of optimal polymer and drug loading and established insight into the final properties and performance of SDASDs at an early stage, therefore enabling the optimization of the scaled-up late-stage development. PMID:29518936

  14. The use of miniature supersonic nozzles for microparticle acceleration: a numerical study.

    PubMed

    Liu, Y

    2007-10-01

    By means of a high-speed gas flow generated by a miniature supersonic nozzle, we proposed a unique biolistic method to accelerate microparticle formulation of drugs to sufficient momentum, to penetrate the outer layer of human skin or mucosal tissue for the treatment of a range of diseases. One of the main concerns for designing and evaluating this system is ensuring microparticles delivery into human skin with a controllable velocity range and spatial distribution. The initial experimental work suggested that the performance of the transdermal delivery strongly depends on aerodynamics of the supersonic nozzles employed. In this paper, computational fluid dynamics (CFD) is utilized to characterize existing prototype biolistic delivery systems, the device with a converging-diverging supersonic nozzle (CDSN) and the device based on the contoured-shock-tube (CST) design, with the aim at investigating the transient gas and particle dynamics in the supersonic nozzles. Whenever possible, predicted pressure and Mach number histories, 2-D flow structures, and particle velocity distributions are made to compare with the corresponding experimental measurements to validate the implemented numerical approach. The gas-particle interaction and performance of two biolistic devices are interrogated and distinguished. Subsequently, the particle impact conditions are presented and discussed. It is demonstrated that the CST can deliver microparticles with a narrow and more controllable velocity range and spatial distribution.

  15. Recommendations for Assessment of the Reliability, Sensitivity, and Validity of Data Provided by Wearable Sensors Designed for Monitoring Physical Activity

    PubMed Central

    2018-01-01

    Although it is becoming increasingly popular to monitor parameters related to training, recovery, and health with wearable sensor technology (wearables), scientific evaluation of the reliability, sensitivity, and validity of such data is limited and, where available, has involved a wide variety of approaches. To improve the trustworthiness of data collected by wearables and facilitate comparisons, we have outlined recommendations for standardized evaluation. We discuss the wearable devices themselves, as well as experimental and statistical considerations. Adherence to these recommendations should be beneficial not only for the individual, but also for regulatory organizations and insurance companies. PMID:29712629

  16. A survey of keystroke dynamics biometrics.

    PubMed

    Teh, Pin Shen; Teoh, Andrew Beng Jin; Yue, Shigang

    2013-01-01

    Research on keystroke dynamics biometrics has been increasing, especially in the last decade. The main motivation behind this effort is due to the fact that keystroke dynamics biometrics is economical and can be easily integrated into the existing computer security systems with minimal alteration and user intervention. Numerous studies have been conducted in terms of data acquisition devices, feature representations, classification methods, experimental protocols, and evaluations. However, an up-to-date extensive survey and evaluation is not yet available. The objective of this paper is to provide an insightful survey and comparison on keystroke dynamics biometrics research performed throughout the last three decades, as well as offering suggestions and possible future research directions.

  17. Evaluation of induction motor performance using an electronic power factor controller

    NASA Technical Reports Server (NTRS)

    1978-01-01

    The concept of reducing the losses in an induction motor by electronically controlling the time interval between the zero crossing of the applied voltage and the zero crossing of the armature current was evaluated. The effect on power losses and power factor of reducing the applied sinusoidal voltages below the rated value was investigated experimentally. The reduction in power losses was measured using an electronic controller designed and built at MSFC. Modifications to the MSFC controller are described as well as a manually controlled electronic device which does not require that the motor be wye connected and the neutral available. Possible energy savings are examined.

  18. Design, Kinematic Optimization, and Evaluation of a Teleoperated System for Middle Ear Microsurgery

    PubMed Central

    Miroir, Mathieu; Nguyen, Yann; Szewczyk, Jérôme; Sterkers, Olivier; Bozorg Grayeli, Alexis

    2012-01-01

    Middle ear surgery involves the smallest and the most fragile bones of the human body. Since microsurgical gestures and a submillimetric precision are required in these procedures, the outcome can be potentially improved by robotic assistance. Today, there is no commercially available device in this field. Here, we describe a method to design a teleoperated assistance robotic system dedicated to the middle ear surgery. Determination of design specifications, the kinematic structure, and its optimization are detailed. The robot-surgeon interface and the command modes are provided. Finally, the system is evaluated by realistic tasks in experimental dedicated settings and in human temporal bone specimens. PMID:22927789

  19. Production of a large, quiescent, magnetized plasma

    NASA Technical Reports Server (NTRS)

    Landt, D. L.; Ajmera, R. C.

    1976-01-01

    An experimental device is described which produces a large homogeneous quiescent magnetized plasma. In this device, the plasma is created in an evacuated brass cylinder by ionizing collisions between electrons emitted from a large-diameter electron gun and argon atoms in the chamber. Typical experimentally measured values of the electron temperature and density are presented which were obtained with a glass-insulated planar Langmuir probe. It is noted that the present device facilitates the study of phenomena such as waves and diffusion in magnetized plasmas.

  20. Mechanical Analog Approach to Parameter Estimation of Lateral Spacecraft Fuel Slosh

    NASA Technical Reports Server (NTRS)

    Chatman, Yadira; Gangadharan, Sathya; Schlee, Keith; Sudermann, James; Walker, Charles; Ristow, James; Hubert, Carl

    2007-01-01

    The nutation (wobble) of a spinning spacecraft in the presence of energy dissipation is a well-known problem in dynamics and is of particular concern for space missions. Even with modern computing systems, CFD type simulations are not fast enough to allow for large scale Monte Carlo analyses of spacecraft and launch vehicle dynamic behavior with slosh included. Simplified mechanical analogs for the slosh are preferred during the initial stages of design to reduce computational time and effort to evaluate the Nutation Time Constant (NTC). Analytic determination of the slosh analog parameters has met with mixed success and is made even more difficult by the introduction of propellant management devices such as elastomeric diaphragms. By subjecting full-sized fuel tanks with actual flight fuel loads to motion similar to that experienced in flight and measuring the forces experienced by the tanks, these parameters can be determined experimentally. Currently, the identification of the model parameters is a laborious trial-and-error process in which the hand-derived equations of motion for the mechanical analog are evaluated and their results compared with the experimental results. Of particular interest is the effect of diaphragms and bladders on the slosh dynamics and how best to model these devices. An experimental set-up is designed and built to include a diaphragm in the simulated spacecraft fuel tank subjected to lateral slosh. This research paper focuses on the parameter estimation of a SimMechanics model of the simulated spacecraft propellant tank with and without diaphragms using lateral fuel slosh experiments. Automating the parameter identification process will save time and thus allow earlier identification of potential vehicle problems.

  1. In situ assessment of shortening and lengthening contractile properties of hind limb ankle flexors in intact mice.

    PubMed

    Gorselink, M; Drost, M R; de Louw, J; Willems, P J; Hesselink, M K; Dekkers, E C; Rosielle, N; van der Vusse, G J

    2001-05-01

    The availability of animal models with disrupted genes has increased the need for small-scale measurement devices. Recently, we developed an experimental device to assess in situ mechanical properties of isometric contractions of intact muscle complexes of the mouse. Although this apparatus provides valuable information on muscle mechanical performance, it is not appropriate for determining contractile properties during shortening and lengthening contractions. In the present study we therefore developed and evaluated an experimental apparatus for assessment of shortening and lengthening contractile properties of intact plantar and dorsal flexors of the mouse. The current through a custom-built, low-inertia servomotor was measured to assess contractile muscular torque ranging from -50 to mN.m. Evaluation of the fixation procedure of the animal to the apparatus via 3-D monitoring of the muscle-tendon complex length showed that the additional shortening in length due to a contraction with maximal torque output has only minor effects on the measured torque. Furthermore, misalignment of the axis of rotation of the apparatus relative to the axis of rotation in the ankle joint, i.e. eccentricity, during a routine experiment was estimated to be less than 1.0 mm and hence did not influence the measured torque output under our experimental conditions. Peak power per unit muscle mass (mean +/- SD) of intact dorsal and plantar flexors was 0.27 +/- 0.02 and 0.19 +/- 0.03 W.g-1, respectively. The angular velocity at maximal peak power generated by the dorsal flexor complex and the plantar flexor complex was 1100 +/- 190 and 700 +/- 90 degrees.s-1, respectively.

  2. Validation of a Mobile Device for Acoustic Coordinated Reset Neuromodulation Tinnitus Therapy.

    PubMed

    Hauptmann, Christian; Wegener, Alexander; Poppe, Hendrik; Williams, Mark; Popelka, Gerald; Tass, Peter A

    2016-10-01

    Sound-based tinnitus intervention stimuli include broad-band noise signals with subjectively adjusted bandwidths used as maskers delivered by commercial devices or hearing aids, environmental sounds broadly described and delivered by both consumer devices and hearing aids, music recordings specifically modified and delivered in a variety of different ways, and other stimuli. Acoustic coordinated reset neuromodulation therapy for tinnitus reduction has unique and more stringent requirements compared to all other sound-based tinnitus interventions. These include precise characterization of tinnitus pitch and loudness, and effective provision of patient-controlled daily therapy signals at defined frequencies, levels, and durations outside of the clinic. The purpose of this study was to evaluate an approach to accommodate these requirements including evaluation of a mobile device, validation of an automated tinnitus pitch-matching algorithm and assessment of a patient's ability to control stimuli and collect repeated outcome measures. The experimental design involved direct laboratory measurements of the sound delivery capabilities of a mobile device, comparison of an automated, adaptive pitch-matching method to a traditional manual method and measures of a patient's ability to understand and manipulate a mobile device graphic user interface to both deliver the therapy signals and collect the outcome measures. This study consisted of 5 samples of a common mobile device for the laboratory measures and a total of 30 adult participants: 15 randomly selected normal-hearing participants with simulated tinnitus for validation of a tinnitus pitch-matching algorithm and 15 sequentially selected patients already undergoing tinnitus therapy for evaluation of patient usability. No tinnitus intervention(s) were specifically studied as a component of this study. Data collection involved laboratory measures of mobile devices, comparison of manual and automated adaptive tinnitus pitch-matching psychoacoustic procedures in the same participant analyzed for absolute differences (t test), variance differences (f test), and range comparisons, and assessment of patient usability including questionnaire measures and logs of patient observations. Mobile devices are able to reliably and accurately deliver the acoustic therapy signals. There was no difference in mean pitch matches (t test, p > 0.05) between an automated adaptive method compared to a traditional manual pitch-matching method. However, the variability of the automated pitch-matching method was much less (f test, p < 0.05) with twice as many matches within the predefined error range (±5%) compared to the manual pitch-matching method (80% versus 40%). After a short initial training, all participants were able to use the mobile device effectively and to perform the required tasks without further professional assistance. American Academy of Audiology

  3. Transient Characteristics of a Fluidic Device for Circulatory Jet Flow.

    PubMed

    Phan, Hoa Thanh; Dinh, Thien Xuan; Bui, Phong Nhu; Dau, Van Thanh

    2018-03-13

    In this paper, we report on the design, simulation, and experimental analysis of a miniaturized device that can generate multiple circulated jet flows. The device is actuated by a lead zirconate titanate (PZT) diaphragm. The flows in the device were studied using three-dimensional transient numerical simulation with the programmable open source OpenFOAM and was comparable to the experimental result. Each flow is verified by two hotwires mounted at two positions inside each consisting chamber. The experiment confirmed that the flow was successfully created, and it demonstrated good agreement with the simulation. In addition, a prospective application of the device as an angular rate sensor is also demonstrated. The device is robust, is minimal in size, and can contribute to the development of multi-axis fluidic inertial sensors, fluidic amplifiers, gas mixing, coupling, and analysis.

  4. Transient Characteristics of a Fluidic Device for Circulatory Jet Flow

    PubMed Central

    Phan, Hoa Thanh; Dinh, Thien Xuan; Bui, Phong Nhu

    2018-01-01

    In this paper, we report on the design, simulation, and experimental analysis of a miniaturized device that can generate multiple circulated jet flows. The device is actuated by a lead zirconate titanate (PZT) diaphragm. The flows in the device were studied using three-dimensional transient numerical simulation with the programmable open source OpenFOAM and was comparable to the experimental result. Each flow is verified by two hotwires mounted at two positions inside each consisting chamber. The experiment confirmed that the flow was successfully created, and it demonstrated good agreement with the simulation. In addition, a prospective application of the device as an angular rate sensor is also demonstrated. The device is robust, is minimal in size, and can contribute to the development of multi-axis fluidic inertial sensors, fluidic amplifiers, gas mixing, coupling, and analysis. PMID:29534014

  5. Constructing experimental devices for half-ton synthesis of gadolinium-loaded liquid scintillator and its performance.

    PubMed

    Park, Young Seo; Jang, Yeong Min; Joo, Kyung Kwang

    2018-04-01

    This paper describes in brief features of various experimental devices constructed for half-ton synthesis of gadolinium(Gd)-loaded liquid scintillator (GdLS) and also includes the performances and detailed chemical and physical results of a 0.5% high-concentration GdLS. Various feasibility studies on useful apparatus used for loading Gd into solvents have been carried out. The transmittance, Gd concentration, density, light yield, and moisture content were measured for quality control. We show that with the help of adequate automated experimental devices and tools, it is possible to perform ton scale synthesis of GdLS at moderate laboratory scale without difficulty. The synthesized GdLS was satisfactory to meet chemical, optical, and physical properties and various safety requirements. These synthesizing devices can be expanded into massive scale next-generation neutrino experiments of several hundred tons.

  6. Flexible energy harvesting from hard piezoelectric beams

    NASA Astrophysics Data System (ADS)

    Delnavaz, Aidin; Voix, Jérémie

    2016-11-01

    This paper presents design, multiphysics finite element modeling and experimental validation of a new miniaturized PZT generator that integrates a bulk piezoelectric ceramic onto a flexible platform for energy harvesting from the human body pressing force. In spite of its flexibility, the mechanical structure of the proposed device is simple to fabricate and efficient for the energy conversion. The finite element model involves both mechanical and piezoelectric parts of the device coupled with the electrical circuit model. The energy harvester prototype was fabricated and tested under the low frequency periodic pressing force during 10 seconds. The experimental results show that several nano joules of electrical energy is stored in a capacitor that is quite significant given the size of the device. The finite element model is validated by observing a good agreement between experimental and simulation results. the validated model could be used for optimizing the device for energy harvesting from earcanal deformations.

  7. Constructing experimental devices for half-ton synthesis of gadolinium-loaded liquid scintillator and its performance

    NASA Astrophysics Data System (ADS)

    Park, Young Seo; Jang, Yeong Min; Joo, Kyung Kwang

    2018-04-01

    This paper describes in brief features of various experimental devices constructed for half-ton synthesis of gadolinium(Gd)-loaded liquid scintillator (GdLS) and also includes the performances and detailed chemical and physical results of a 0.5% high-concentration GdLS. Various feasibility studies on useful apparatus used for loading Gd into solvents have been carried out. The transmittance, Gd concentration, density, light yield, and moisture content were measured for quality control. We show that with the help of adequate automated experimental devices and tools, it is possible to perform ton scale synthesis of GdLS at moderate laboratory scale without difficulty. The synthesized GdLS was satisfactory to meet chemical, optical, and physical properties and various safety requirements. These synthesizing devices can be expanded into massive scale next-generation neutrino experiments of several hundred tons.

  8. Development of a mini-mobile digital radiography system by using wireless smart devices.

    PubMed

    Jeong, Chang-Won; Joo, Su-Chong; Ryu, Jong-Hyun; Lee, Jinseok; Kim, Kyong-Woo; Yoon, Kwon-Ha

    2014-08-01

    The current technologies that trend in digital radiology (DR) are toward systems using portable smart mobile as patient-centered care. We aimed to develop a mini-mobile DR system by using smart devices for wireless connection into medical information systems. We developed a mini-mobile DR system consisting of an X-ray source and a Complementary Metal-Oxide Semiconductor (CMOS) sensor based on a flat panel detector for small-field diagnostics in patients. It is used instead of the systems that are difficult to perform with a fixed traditional device. We also designed a method for embedded systems in the development of portable DR systems. The external interface used the fast and stable IEEE 802.11n wireless protocol, and we adapted the device for connections with Picture Archiving and Communication System (PACS) and smart devices. The smart device could display images on an external monitor other than the monitor in the DR system. The communication modules, main control board, and external interface supporting smart devices were implemented. Further, a smart viewer based on the external interface was developed to display image files on various smart devices. In addition, the advantage of operators is to reduce radiation dose when using remote smart devices. It is integrated with smart devices that can provide X-ray imaging services anywhere. With this technology, it can permit image observation on a smart device from a remote location by connecting to the external interface. We evaluated the response time of the mini-mobile DR system to compare to mobile PACS. The experimental results show that our system outperforms conventional mobile PACS in this regard.

  9. Effects of far-infrared irradiation on myofascial neck pain: a randomized, double-blind, placebo-controlled pilot study.

    PubMed

    Lai, Chien-Hung; Leung, Ting-Kai; Peng, Chih-Wei; Chang, Kwang-Hwa; Lai, Ming-Jun; Lai, Wen-Fu; Chen, Shih-Ching

    2014-02-01

    The objective of this study was to determine the relative efficacy of irradiation using a device containing a far-infrared emitting ceramic powder (cFIR) for the management of chronic myofascial neck pain compared with a control treatment. This was a randomized, double-blind, placebo-controlled pilot study. The study comprised 48 patients with chronic, myofascial neck pain. Patients were randomly assigned to the experimental group or the control (sham-treatment) group. The patients in the experimental group wore a cFIR neck device for 1 week, and the control group wore an inert neck device for 1 week. Quantitative measurements based on a visual analogue scale (VAS) scoring of pain, a sleep quality assessment, pressure-pain threshold (PPT) testing, muscle tone and compliance analysis, and skin temperature analysis were obtained. Both the experimental and control groups demonstrated significant improvement in pain scores. However, no statistically significant difference in the pain scores was observed between the experimental and control groups. Significant decreases in muscle stiffness in the upper regions of the trapezius muscles were reported in the experimental group after 1 week of treatment. Short-term treatment using the cFIR neck device partly reduced muscle stiffness. Although the differences in the VAS and PPT scores for the experimental and control groups were not statistically significant, the improvement in muscle stiffness in the experimental group warrants further investigation of the long-term effects of cFIR treatment for pain management.

  10. Evaluation of microfluidic channels with optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Czajkowski, J.; Prykäri, T.; Alarousu, E.; Lauri, J.; Myllylä, R.

    2010-11-01

    Application of time domain, ultra high resolution optical coherence tomography (UHR-OCT) in evaluation of microfluidic channels is demonstrated. Presented study was done using experimental UHR-OCT device based on a Kerr-lens mode locked Ti:sapphire femtosecond laser, a photonic crystal fibre and modified, free-space Michelson interferometer. To show potential of the technique, microfluidic chip fabricated by VTT Center for Printed Intelligence (Oulu, Finland) was measured. Ability for full volumetric reconstruction in non-contact manner enabled complete characterization of closed entity of a microfluidic channel without contamination and harm for the sample. Measurement, occurring problems, and methods of postprocessing for raw data are described. Results present completely resolved physical structure of the channel, its spatial dimensions, draft angles and evaluation of lamination quality.

  11. Experimental study of the novel tuned mass damper with inerter which enables changes of inertance

    NASA Astrophysics Data System (ADS)

    Brzeski, P.; Lazarek, M.; Perlikowski, P.

    2017-09-01

    In this paper we present the experimental verification of the novel tuned mass damper which enables changes of inertance. Characteristic feature of the proposed device is the presence of special type of inerter. This inerter incorporates a continuously variable transmission that enables stepless changes of inertance. Thus, it enables to adjust the parameters of the damping device to the current forcing characteristic. In the paper we present and describe the experimental rig that consists of the massive main oscillator forced kinematically and the prototype of the investigated damper. We perform a series of dedicated experiments to characterize the device and asses its damping efficiency. Moreover, we perform numerical simulations using the simple mathematical model of investigated system. Comparing the numerical results and the experimental data we legitimize the model and demonstrate the capabilities of the investigated tuned mass damper. Presented results prove that the concept of the novel type of tuned mass damper can be realized and enable to confirm its main advantages. Investigated prototype device offers excellent damping efficiency in a wide range of forcing frequencies.

  12. Flushing ports of totally implantable venous access devices, and impact of the Huber point needle bevel orientation: experimental tests and numerical computation.

    PubMed

    Guiffant, Gérard; Durussel, Jean Jacques; Flaud, Patrice; Vigier, Jean Pierre; Merckx, Jacques

    2012-01-01

    The use of totally implantable venous access devices developed as a medical device allowing mid- and long-term, frequent, repeated, or continuous injection of therapeutic products, by vascular, cavitary, or perineural access. The effective flushing of these devices is a central element to assure long-lasting use. Our experimental work demonstrates that directing the Huber point needle opening in the diametrically opposite direction of the implantable port exit channel increases the flushing efficiency. These results are consolidated by numerical computations, which support recommendations not only for their maintenance, but also for their use.

  13. Flushing ports of totally implantable venous access devices, and impact of the Huber point needle bevel orientation: experimental tests and numerical computation

    PubMed Central

    Guiffant, Gérard; Durussel, Jean Jacques; Flaud, Patrice; Vigier, Jean Pierre; Merckx, Jacques

    2012-01-01

    The use of totally implantable venous access devices developed as a medical device allowing mid- and long-term, frequent, repeated, or continuous injection of therapeutic products, by vascular, cavitary, or perineural access. The effective flushing of these devices is a central element to assure long-lasting use. Our experimental work demonstrates that directing the Huber point needle opening in the diametrically opposite direction of the implantable port exit channel increases the flushing efficiency. These results are consolidated by numerical computations, which support recommendations not only for their maintenance, but also for their use. PMID:23166455

  14. Room-temperature ballistic transport in III-nitride heterostructures.

    PubMed

    Matioli, Elison; Palacios, Tomás

    2015-02-11

    Room-temperature (RT) ballistic transport of electrons is experimentally observed and theoretically investigated in III-nitrides. This has been largely investigated at low temperatures in low band gap III-V materials due to their high electron mobilities. However, their application to RT ballistic devices is limited by their low optical phonon energies, close to KT at 300 K. In addition, the short electron mean-free-path at RT requires nanoscale devices for which surface effects are a limitation in these materials. We explore the unique properties of wide band-gap III-nitride semiconductors to demonstrate RT ballistic devices. A theoretical model is proposed to corroborate experimentally their optical phonon energy of 92 meV, which is ∼4× larger than in other III-V semiconductors. This allows RT ballistic devices operating at larger voltages and currents. An additional model is described to determine experimentally a characteristic dimension for ballistic transport of 188 nm. Another remarkable property is their short carrier depletion at device sidewalls, down to 13 nm, which allows top-down nanofabrication of very narrow ballistic devices. These results open a wealth of new systems and basic transport studies possible at RT.

  15. Inter-laboratory evaluation of the performance parameters of a Lateral Flow Test device for the detection of Bluetongue virus-specific antibodies.

    PubMed

    Hanon, Jean-Baptiste; Vandenberge, Valerie; Deruelle, Matthias; De Leeuw, Ilse; De Clercq, Kris; Van Borm, Steven; Koenen, Frank; Liu, Lihong; Hoffmann, Bernd; Batten, Carrie Anne; Zientara, Stéphan; Breard, Emmanuel; Van der Stede, Yves

    2016-02-01

    Bluetongue (BT) is a viral vector-borne disease affecting domestic and wild ruminants worldwide. In this study, a commercial rapid immuno-chromatographic method or Lateral Flow Test (LFT) device, for the detection of BT virus-specific antibodies in animal serum, was evaluated in an international inter-laboratory proficiency test. The evaluation was done with sera samples of variable background (ruminant species, serotype, field samples, experimental infections, vaccinated animals). The diagnostic sensitivity was 100% (95% C.I. [90.5-100]) and the diagnostic specificity was 95.2% (95% C.I. [76.2-99.9]). The repeatability (accordance) and reproducibility (concordance) were 100% for seropositive samples but were lower for two of the seronegative samples (45% and 89% respectively). The analytical sensitivity, evaluated by testing positive sera at increasing dilutions was better for the BT LFT compared to some commercial ELISAs. Seroconversion of an infected sheep was detected at 4 days post infection. Analytical specificity was impaired by cross-reactions observed with some of the samples seropositive for Epizootic Haemorrhagic Disease Virus (EHDV). The agreement (Cohen's kappa) between the LFT and a commercial BT competitive ELISA was 0.79 (95% CI [0.62-0.95]). Based on these results, it can be concluded that the BT LFT device is a rapid and sensitive first-line serological test that can be used in the field, especially in areas endemic for the disease where there is a lack of diagnostic facilities. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Quantum-Dot Cellular Automata

    NASA Astrophysics Data System (ADS)

    Snider, Gregory

    2000-03-01

    Quantum-dot Cellular Automata (QCA) [1] is a promising architecture which employs quantum dots for digital computation. It is a revolutionary approach that holds the promise of high device density and low power dissipation. A basic QCA cell consists of four quantum dots coupled capacitively and by tunnel barriers. The cell is biased to contain two excess electrons within the four dots, which are forced to opposite "corners" of the four-dot cell by mutual Coulomb repulsion. These two possible polarization states of the cell will represent logic "0" and "1". Properly arranged, arrays of these basic cells can implement Boolean logic functions. Experimental results from functional QCA devices built of nanoscale metal dots defined by tunnel barriers will be presented. The experimental devices to be presented consist of Al islands, which we will call quantum dots, interconnected by tunnel junctions and lithographically defined capacitors. Aluminum/ aluminum-oxide/aluminum tunnel junctions were fabricated using a standard e-beam lithography and shadow evaporation technique. The experiments were performed in a dilution refrigerator at a temperature of 70 mK. The operation of a cell is evaluated by direct measurements of the charge state of dots within a cell as the input voltage is changed. The experimental demonstration of a functioning cell will be presented. A line of three cells demonstrates that there are no metastable switching states in a line of cells. A QCA majority gate will also be presented, which is a programmable AND/OR gate and represents the basic building block of QCA systems. The results of recent experiments will be presented. 1. C.S. Lent, P.D. Tougaw, W. Porod, and G.H. Bernstein, Nanotechnology, 4, 49 (1993).

  17. Subcellular glucose exposure biases the spatial distribution of insulin granules in single pancreatic beta cells.

    PubMed

    Terao, Kyohei; Gel, Murat; Okonogi, Atsuhito; Fuke, Ariko; Okitsu, Teru; Tada, Takashi; Suzuki, Takaaki; Nagamatsu, Shinya; Washizu, Masao; Kotera, Hidetoshi

    2014-02-18

    In living tissues, a cell is exposed to chemical substances delivered partially to its surface. Such a heterogeneous chemical environment potentially induces cell polarity. To evaluate this effect, we developed a microfluidic device that realizes spatially confined delivery of chemical substances at subcellular resolution. Our microfluidic device allows simple setup and stable operation for over 4 h to deliver chemicals partially to a single cell. Using the device, we showed that subcellular glucose exposure triggers an intracellular [Ca(2+)] change in the β-cells. In addition, the imaging of a cell expressing GFP-tagged insulin showed that continuous subcellular exposure to glucose biased the spatial distribution of insulin granules toward the site where the glucose was delivered. Our approach illustrates an experimental technique that will be applicable to many biological experiments for imaging the response to subcellular chemical exposure and will also provide new insights about the development of polarity of β-cells.

  18. Subcellular glucose exposure biases the spatial distribution of insulin granules in single pancreatic beta cells

    PubMed Central

    Terao, Kyohei; Gel, Murat; Okonogi, Atsuhito; Fuke, Ariko; Okitsu, Teru; Tada, Takashi; Suzuki, Takaaki; Nagamatsu, Shinya; Washizu, Masao; Kotera, Hidetoshi

    2014-01-01

    In living tissues, a cell is exposed to chemical substances delivered partially to its surface. Such a heterogeneous chemical environment potentially induces cell polarity. To evaluate this effect, we developed a microfluidic device that realizes spatially confined delivery of chemical substances at subcellular resolution. Our microfluidic device allows simple setup and stable operation for over 4 h to deliver chemicals partially to a single cell. Using the device, we showed that subcellular glucose exposure triggers an intracellular [Ca2+] change in the β-cells. In addition, the imaging of a cell expressing GFP-tagged insulin showed that continuous subcellular exposure to glucose biased the spatial distribution of insulin granules toward the site where the glucose was delivered. Our approach illustrates an experimental technique that will be applicable to many biological experiments for imaging the response to subcellular chemical exposure and will also provide new insights about the development of polarity of β-cells. PMID:24535122

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zainudin, Mohd Lutfi, E-mail: mdlutfi07@gmail.com; Institut Matematik Kejuruteraan; Saaban, Azizan, E-mail: azizan.s@uum.edu.my

    The solar radiation values have been composed by automatic weather station using the device that namely pyranometer. The device is functions to records all the radiation values that have been dispersed, and these data are very useful for it experimental works and solar device’s development. In addition, for modeling and designing on solar radiation system application is needed for complete data observation. Unfortunately, lack for obtained the complete solar radiation data frequently occur due to several technical problems, which mainly contributed by monitoring device. Into encountering this matter, estimation missing values in an effort to substitute absent values with imputedmore » data. This paper aimed to evaluate several piecewise interpolation techniques likes linear, splines, cubic, and nearest neighbor into dealing missing values in hourly solar radiation data. Then, proposed an extendable work into investigating the potential used of cubic Bezier technique and cubic Said-ball method as estimator tools. As result, methods for cubic Bezier and Said-ball perform the best compare to another piecewise imputation technique.« less

  20. Study of liquid and vapor flow into a Centaur capillary device

    NASA Technical Reports Server (NTRS)

    Blatt, M. H.; Risberg, J. A.

    1979-01-01

    The following areas of liquid and vapor flow were analyzed and experimentally evaluated; 1) the refilling of capillary devices with settled liquid, and 2) vapor flow across wetted screens. These investigations resulted in: 1) the development of a versatile computer program that was successfully correlated with test data and used to predict Centaur D-1S LO2 and LH2 start basket refilling; 2) the development of a semi-empirical model that was only partially correlated with data due to difficulties in obtaining repeatable test results. Also, a comparison was made to determine the best propellant management system for the Centaur D-1S vehicle. The comparison identified the basline Centaur D-1S system (using pressurization, boost pumps and propellant settling) as the best candidate based on payload weight penalty. However, other comparison criteria and advanced mission condition were identified where pressure fed systems, thermally subcooled boost pumps and capillary devices would be selected as attractive alternatives.

  1. A Real-Time Web of Things Framework with Customizable Openness Considering Legacy Devices

    PubMed Central

    Zhao, Shuai; Yu, Le; Cheng, Bo

    2016-01-01

    With the development of the Internet of Things (IoT), resources and applications based on it have emerged on a large scale. However, most efforts are “silo” solutions where devices and applications are tightly coupled. Infrastructures are needed to connect sensors to the Internet, open up and break the current application silos and move to a horizontal application mode. Based on the concept of Web of Things (WoT), many infrastructures have been proposed to integrate the physical world with the Web. However, issues such as no real-time guarantee, lack of fine-grained control of data, and the absence of explicit solutions for integrating heterogeneous legacy devices, hinder their widespread and practical use. To address these issues, this paper proposes a WoT resource framework that provides the infrastructures for the customizable openness and sharing of users’ data and resources under the premise of ensuring the real-time behavior of their own applications. The proposed framework is validated by actual systems and experimental evaluations. PMID:27690038

  2. A Real-Time Web of Things Framework with Customizable Openness Considering Legacy Devices.

    PubMed

    Zhao, Shuai; Yu, Le; Cheng, Bo

    2016-09-28

    With the development of the Internet of Things (IoT), resources and applications based on it have emerged on a large scale. However, most efforts are "silo" solutions where devices and applications are tightly coupled. Infrastructures are needed to connect sensors to the Internet, open up and break the current application silos and move to a horizontal application mode. Based on the concept of Web of Things (WoT), many infrastructures have been proposed to integrate the physical world with the Web. However, issues such as no real-time guarantee, lack of fine-grained control of data, and the absence of explicit solutions for integrating heterogeneous legacy devices, hinder their widespread and practical use. To address these issues, this paper proposes a WoT resource framework that provides the infrastructures for the customizable openness and sharing of users' data and resources under the premise of ensuring the real-time behavior of their own applications. The proposed framework is validated by actual systems and experimental evaluations.

  3. Spectroscopic refractometer for transparent and absorbing liquids by reflection of white light near the critical angle

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sanchez-Perez, C.; Garcia-Valenzuela, A.

    2012-11-15

    We propose and evaluate a spectroscopic refractometer device to measure the refractive index dispersion of transparent and absorbing solutions. The angle-dependent reflectivity of a white beam of light in an internal reflection configuration around the critical angle is spectrally analyzed. The refractive index in a wavelength range from 400 nm to 900 nm is obtained from the angle-reflectivity curve around the critical angle at each wavelength. The device does not use angle scanning mechanisms, decreasing considerably the complexity of the instrument in comparison to previous proposals. As a result, the measurements are obtained relatively fast. Nevertheless, a good experimental resolutionmore » in refractive index of about {Delta}n Almost-Equal-To 10{sup -4} at all the wavelengths is achieved in the case of transparent solutions. The calibration procedure of the device is discussed in detail. We also present measurements of the refractive index dispersion of rhodamine 6G-methanol solutions, which has a strong absorption band in the visible spectra.« less

  4. Application Performance Analysis and Efficient Execution on Systems with multi-core CPUs, GPUs and MICs: A Case Study with Microscopy Image Analysis

    PubMed Central

    Teodoro, George; Kurc, Tahsin; Andrade, Guilherme; Kong, Jun; Ferreira, Renato; Saltz, Joel

    2015-01-01

    We carry out a comparative performance study of multi-core CPUs, GPUs and Intel Xeon Phi (Many Integrated Core-MIC) with a microscopy image analysis application. We experimentally evaluate the performance of computing devices on core operations of the application. We correlate the observed performance with the characteristics of computing devices and data access patterns, computation complexities, and parallelization forms of the operations. The results show a significant variability in the performance of operations with respect to the device used. The performances of operations with regular data access are comparable or sometimes better on a MIC than that on a GPU. GPUs are more efficient than MICs for operations that access data irregularly, because of the lower bandwidth of the MIC for random data accesses. We propose new performance-aware scheduling strategies that consider variabilities in operation speedups. Our scheduling strategies significantly improve application performance compared to classic strategies in hybrid configurations. PMID:28239253

  5. Development of high temperature containerless processing equipment and the design and evaluation of associated systems required for microgravity materials processing and property measurements

    NASA Technical Reports Server (NTRS)

    Rey, Charles A.

    1991-01-01

    The development of high temperature containerless processing equipment and the design and evaluation of associated systems required for microgravity materials processing and property measurements are discussed. Efforts were directed towards the following task areas: design and development of a High Temperature Acoustic Levitator (HAL) for containerless processing and property measurements at high temperatures; testing of the HAL module to establish this technology for use as a positioning device for microgravity uses; construction and evaluation of a brassboard hot wall Acoustic Levitation Furnace; construction and evaluation of a noncontact temperature measurement (NCTM) system based on AGEMA thermal imaging camera; construction of a prototype Division of Amplitude Polarimetric Pyrometer for NCTM of levitated specimens; evaluation of and recommendations for techniques to control contamination in containerless materials processing chambers; and evaluation of techniques for heating specimens to high temperatures for containerless materials experimentation.

  6. Development of high temperature containerless processing equipment and the design and evaluation of associated systems required for microgravity materials processing and property measurements

    NASA Astrophysics Data System (ADS)

    Rey, Charles A.

    1991-03-01

    The development of high temperature containerless processing equipment and the design and evaluation of associated systems required for microgravity materials processing and property measurements are discussed. Efforts were directed towards the following task areas: design and development of a High Temperature Acoustic Levitator (HAL) for containerless processing and property measurements at high temperatures; testing of the HAL module to establish this technology for use as a positioning device for microgravity uses; construction and evaluation of a brassboard hot wall Acoustic Levitation Furnace; construction and evaluation of a noncontact temperature measurement (NCTM) system based on AGEMA thermal imaging camera; construction of a prototype Division of Amplitude Polarimetric Pyrometer for NCTM of levitated specimens; evaluation of and recommendations for techniques to control contamination in containerless materials processing chambers; and evaluation of techniques for heating specimens to high temperatures for containerless materials experimentation.

  7. Closed Loop Two-Phase Thermosyphon of Small Dimensions: a Review of the Experimental Results

    NASA Astrophysics Data System (ADS)

    Franco, Alessandro; Filippeschi, Sauro

    2012-06-01

    A bibliographical review on the heat and mass transfer in gravity assisted Closed Loop Two Phase Thermosyphons (CLTPT) with channels having a hydraulic diameter of the order of some millimetres and input power below 1 kW is proposed. The available experimental works in the literature are critically analysed in order to highlight the main results and the correlation between mass flow rate and heat input in natural circulation loops. A comparison of different experimental apparatuses and results is made. It is observed that the results are very different among them and in many cases the experimental data disagree with the conventional theory developed for an imposed flow rate. The paper analyses the main differences among the experimental devices and try to understand these disagreements. From the present analysis it is evident that further systematic studies are required to generate a meaningful body of knowledge of the heat and mass transport mechanism in these devices for practical applications in cooling devices or energy systems.

  8. Spacecraft particulate sizing spectrometer

    NASA Technical Reports Server (NTRS)

    Miranda, Henry A., Jr.

    1992-01-01

    An evaluation prototype device is described, together with conclusions and several recommendations for follow-on flight hardware. The device detects individual particles crossing an external sensing zone, and produces a histogram displaying the size distribution of particles sensed, over the nominal range of 5 to 50 microns. The output is totally independent of the particle refractive index, and is also largely unaffected by particle shape. The reported diameters are in terms of the equivalent sphere, as judged by the scattered light intercepted by the receiving channels, which develop signals whenever a particle crosses the beam of illumination in the sensing zone. Supporting evidence for the latter assertion is discussed on the basis of experimental test data for non-spherical particulates. Also included is a technical appendix which presents theoretical arguments that provide a firm foundation for this assertion.

  9. Evaluation of 1.5-T Cell Flash Memory Total Ionizing Dose Response

    NASA Astrophysics Data System (ADS)

    Clark, Lawrence T.; Holbert, Keith E.; Adams, James W.; Navale, Harshad; Anderson, Blake C.

    2015-12-01

    Flash memory is an essential part of systems used in harsh environments, experienced by both terrestrial and aerospace TID applications. This paper presents studies of COTS flash memory TID hardness. While there is substantial literature on flash memory TID response, this work focuses for the first time on 1.5 transistor per cell flash memory. The experimental results show hardness varying from about 100 krad(Si) to over 250 krad(Si) depending on the usage model. We explore the circuit and device aspects of the results, based on the extensive reliability literature for this flash memory type. Failure modes indicate both device damage and circuit marginalities. Sector erase failure limits, but read only operation allows TID exceeding 200 krad(Si). The failures are analyzed by type.

  10. Ultrasound measurement apparatus for liquids characterization

    NASA Astrophysics Data System (ADS)

    Vieira, R. C.; Costa-Felix, R. P. B.

    2018-03-01

    The present paper discloses the validation of an experimental ultrasound apparatus and method for liquids characterization. The research aims to stablish a simple, reliable, accurate and portable way to identify contaminants in hydrocarbon substances, such as adulteration in gasoline. The results depicted so far demonstrated a general uncertainty of speed of sound assessment less than 10 m s-1, and distance accuracy of less than 1%. Those figures are good enough for an in-site device to evaluate possible contamination of fuels or other liquids.

  11. Performance characterization of polarimetric active radar calibrators and a new single antenna design

    NASA Astrophysics Data System (ADS)

    Sarabandi, Kamal; Oh, Yisok; Ulaby, Fawwaz T.

    1992-10-01

    Three aspects of a polarimetric active radar calibrator (PARC) are treated: (1) experimental measurements of the magnitudes and phases of the scattering-matrix elements of a pair of PARCs operating at 1.25 and 5.3 GHz; (2) the design, construction, and performance evaluation of a PARC; and (3) the extension of the single-target-calibration technique (STCT) to a PARC. STCT has heretofore been limited to the use of reciprocal passive calibration devices, such as spheres and trihedral corner reflectors.

  12. Performance characterization of polarimetric active radar calibrators and a new single antenna design

    NASA Technical Reports Server (NTRS)

    Sarabandi, Kamal; Oh, Yisok; Ulaby, Fawwaz T.

    1992-01-01

    Three aspects of a polarimetric active radar calibrator (PARC) are treated: (1) experimental measurements of the magnitudes and phases of the scattering-matrix elements of a pair of PARCs operating at 1.25 and 5.3 GHz; (2) the design, construction, and performance evaluation of a PARC; and (3) the extension of the single-target-calibration technique (STCT) to a PARC. STCT has heretofore been limited to the use of reciprocal passive calibration devices, such as spheres and trihedral corner reflectors.

  13. C-shaped specimen plane strain fracture toughness tests. [metallic materials

    NASA Technical Reports Server (NTRS)

    Buzzard, R. T.; Fisher, D. M.

    1977-01-01

    Test equipment, procedures, and data obtained in the evaluation of C-shaped specimens are presented. Observations reported on include: specimen preparation and dimensional measurement; modifications to the standard ASTM E 399 displacement gage, which permit punch mark gage point engagement; and a measurement device for determining the interior and exterior radii of ring segments. Load displacement ratios were determined experimentally which agreed with analytically determined coefficients for three different gage lengths on the inner surfaces of radially-cracked ring segments.

  14. Heat storage capability of a rolling cylinder using Glauber's salt

    NASA Technical Reports Server (NTRS)

    Herrick, C. S.; Zarnoch, K. P.

    1980-01-01

    The rolling cylinder phase change heat storage concept was developed to the point where a prototype design is completed and a cost analysis is prepared. A series of experimental and analytical tasks are defined to establish the thermal, mechanical, and materials behavior of rolling cylinder devices. These tasks include: analyses of internal and external heat transfer; performance and lifetime testing of the phase change materials; corrosion evaluation; development of a mathematical model; and design of a prototype and associated test equipment.

  15. Modeling and experimental result analysis for high-power VECSELs

    NASA Astrophysics Data System (ADS)

    Zakharian, Aramais R.; Hader, Joerg; Moloney, Jerome V.; Koch, Stephan W.; Lutgen, Stephan; Brick, Peter; Albrecht, Tony; Grotsch, Stefan; Luft, Johann; Spath, Werner

    2003-06-01

    We present a comparison of experimental and microscopically based model results for optically pumped vertical external cavity surface emitting semiconductor lasers. The quantum well gain model is based on a quantitative ab-initio approach that allows calculation of a complex material susceptibility dependence on the wavelength, carrier density and lattice temperature. The gain model is coupled to the macroscopic thermal transport, spatially resolved in both the radial and longitudinal directions, with temperature and carrier density dependent pump absorption. The radial distribution of the refractive index and gain due to temperature variation are computed. Thermal managment issues, highlighted by the experimental data, are discussed. Experimental results indicate a critical dependence of the input power, at which thermal roll-over occurs, on the thermal resistance of the device. This requires minimization of the substrate thickness and optimization of the design and placement of the heatsink. Dependence of the model results on the radiative and non-radiative carrier recombination lifetimes and cavity losses are evaluated.

  16. Improvement of vibration energy harvesters mechanical Q-factor through high density proof mass integration

    NASA Astrophysics Data System (ADS)

    Dompierre, A.; Fréchette, L. G.

    2016-11-01

    This paper reports on improvement of the mechanical Q-factor of resonant energy harvesters at ambient pressure via the use of tungsten proof masses by evaluating the impact of the mass size and density on the squeeze film damping. To this end, a simplified model is first proposed to evaluate cantilever beams deflection and the resulting fluid pressure build up between the mass and a near surface. The model, which accounts for simultaneous transverse and rotational motion of very long tip masses as well as for 2D fluid flow in the gap, is used to extract a scaling law for the device fluidic Q-factor Qf. This law states that Qf can be improved by either increasing the linear mass density of the tip mass or by reducing the side lengths compared to the gap height. The first approach is validated experimentally by adding a tungsten proof mass on a silicon based device and observing an improvement of the Q-factor by 103%, going from 430 to 871, while the resonance frequency drops from 457 to 127 Hz. In terms of fluidic Q-factor, this represents an increase from 562 to 1673. These results successfully demonstrate the benefits of integrating a tungsten mass to reduce the fluid losses while potentially reducing the device footprint.

  17. Comparison of Saliva Collection Methods for the Determination of Salivary Cortisol Levels in Rhesus Macaques (Macaca mulatta), Cynomolgus Macaques (Macaca fascicularis), and African Green Monkeys (Chlorocebus aethiops)

    PubMed Central

    Rapp-Santos, Kamala J; Altamura, Louis A; Norris, Sarah L; Lugo-Roman, Luis A; Rico, Pedro J; Hofer, Christian C

    2017-01-01

    The ability to quickly and accurately determine cortisol as a biomarker for stress is a valuable tool in assessing the wellbeing of NHP. In this study, 2 methods of collecting saliva (a commercial collection device and passive drool) and the resulting free salivary cortisol levels were compared with total serum cortisol concentration in rhesus macaques (Macaca mulatta), cynomolgus macaques (Macaca fascicularis) and African green monkeys (Chlorocebus aethiops) at 2 collection time points. Serum and salivary cortisol levels were determined using a competitive quantitative ELISA. In addition, both saliva collection methods were evaluated for volume collected and ease of use. Compared with passive drool, the experimental collection device was more reliable in collecting sufficient volumes of saliva, and the resulting salivary cortisol values demonstrated stronger correlation with serum cortisol concentration in all species and collection days except cynomolgus macaques on day 1. This saliva collection device allows quick and reliable sample collection for the determination of salivary cortisol levels. In addition, the results might provide a useful tool for evaluating hypothalamic-pituitary-adrenal axis activity or the physiologic stress reaction in NHP as well as a biomarker of psychologic stress states in a variety of situations. PMID:28315649

  18. Biaxial experimental and analytical characterization of a dielectric elastomer

    NASA Astrophysics Data System (ADS)

    Helal, Alexander; Doumit, Marc; Shaheen, Robert

    2018-01-01

    Electroactive polymers (EAPs) have emerged as a strong contender for use in low-cost efficient actuators in multiple applications especially related to biomimetic and mobile-assistive devices. Dielectric elastomers (DE), a subcategory of these smart materials, have been of particular interest due to their large achievable deformation and favourable mechanical and electro-mechanical properties. Previous work has been completed to understand the behaviour of these materials; however, their properties require further investigation to properly integrate them into real-world applications. In this study, a biaxial tensile experimental evaluation of 3M™ VHB 4905 and VHB 4910 is presented with the purpose of illustrating the elastomers' transversely isotropic mechanical behaviours. These tests were applied to both tapes for equibiaxial stretch rates ranging between 0.025 and 0.300 s-1. Subsequently, a dynamic planar biaxial visco-hyperelastic constitutive relationship was derived from a Kelvin-Voigt rheological model and the general Hooke's law for transversely isotropic materials. The model was then fitted to the experimental data to obtain three general material parameters for either tapes. The model's ability to predict tensile stress response and internal energy dissipation, with respect to experimental data, is evaluated with good agreement. The model's ability to predict variations in mechanical behaviour due to changes in kinematic variables is then illustrated for different conditions.

  19. Using tablet technology and instructional videos to enhance preclinical dental laboratory learning.

    PubMed

    Gadbury-Amyot, Cynthia C; Purk, John H; Williams, Brian Joseph; Van Ness, Christopher J

    2014-02-01

    The purpose of this pilot study was to examine if tablet technology with accompanying instructional videos enhanced the teaching and learning outcomes in a preclinical dental laboratory setting. Two procedures deemed most challenging in Operative Dentistry II were chosen for the development of instructional videos. A random sample of thirty students was chosen to participate in the pilot. Comparison of faculty evaluations of the procedures between the experimental (tablet) and control (no tablet) groups resulted in no significant differences; however, there was a trend toward fewer failures in the experimental group. Examination of the ability to accurately self-assess was compared by exploring correlations between faculty and student evaluations. While correlations were stronger in the experimental group, the control group had significant correlations for all three procedures, while the experimental group had significant correlations on only two of the procedures. Students strongly perceived that the tablets and videos helped them perform better and more accurately self-assess their work products. Students did not support requiring that they purchase/obtain a specific brand of technology. As a result of this pilot study, further development of ideal and non-ideal videos are in progress, and the school will be implementing a "Bring Your Own Device" policy with incoming students.

  20. Integrated trimodal SSEP experimental setup for visual, auditory and tactile stimulation

    NASA Astrophysics Data System (ADS)

    Kuś, Rafał; Spustek, Tomasz; Zieleniewska, Magdalena; Duszyk, Anna; Rogowski, Piotr; Suffczyński, Piotr

    2017-12-01

    Objective. Steady-state evoked potentials (SSEPs), the brain responses to repetitive stimulation, are commonly used in both clinical practice and scientific research. Particular brain mechanisms underlying SSEPs in different modalities (i.e. visual, auditory and tactile) are very complex and still not completely understood. Each response has distinct resonant frequencies and exhibits a particular brain topography. Moreover, the topography can be frequency-dependent, as in case of auditory potentials. However, to study each modality separately and also to investigate multisensory interactions through multimodal experiments, a proper experimental setup appears to be of critical importance. The aim of this study was to design and evaluate a novel SSEP experimental setup providing a repetitive stimulation in three different modalities (visual, tactile and auditory) with a precise control of stimuli parameters. Results from a pilot study with a stimulation in a particular modality and in two modalities simultaneously prove the feasibility of the device to study SSEP phenomenon. Approach. We developed a setup of three separate stimulators that allows for a precise generation of repetitive stimuli. Besides sequential stimulation in a particular modality, parallel stimulation in up to three different modalities can be delivered. Stimulus in each modality is characterized by a stimulation frequency and a waveform (sine or square wave). We also present a novel methodology for the analysis of SSEPs. Main results. Apart from constructing the experimental setup, we conducted a pilot study with both sequential and simultaneous stimulation paradigms. EEG signals recorded during this study were analyzed with advanced methodology based on spatial filtering and adaptive approximation, followed by statistical evaluation. Significance. We developed a novel experimental setup for performing SSEP experiments. In this sense our study continues the ongoing research in this field. On the other hand, the described setup along with the presented methodology is a considerable improvement and an extension of methods constituting the state-of-the-art in the related field. Device flexibility both with developed analysis methodology can lead to further development of diagnostic methods and provide deeper insight into information processing in the human brain.

  1. Evaluation of Wearable Haptic Systems for the Fingers in Augmented Reality Applications.

    PubMed

    Maisto, Maurizio; Pacchierotti, Claudio; Chinello, Francesco; Salvietti, Gionata; De Luca, Alessandro; Prattichizzo, Domenico

    2017-01-01

    Although Augmented Reality (AR) has been around for almost five decades, only recently we have witnessed AR systems and applications entering in our everyday life. Representative examples of this technological revolution are the smartphone games "Pokémon GO" and "Ingress" or the Google Translate real-time sign interpretation app. Even if AR applications are already quite compelling and widespread, users are still not able to physically interact with the computer-generated reality. In this respect, wearable haptics can provide the compelling illusion of touching the superimposed virtual objects without constraining the motion or the workspace of the user. In this paper, we present the experimental evaluation of two wearable haptic interfaces for the fingers in three AR scenarios, enrolling 38 participants. In the first experiment, subjects were requested to write on a virtual board using a real chalk. The haptic devices provided the interaction forces between the chalk and the board. In the second experiment, subjects were asked to pick and place virtual and real objects. The haptic devices provided the interaction forces due to the weight of the virtual objects. In the third experiment, subjects were asked to balance a virtual sphere on a real cardboard. The haptic devices provided the interaction forces due to the weight of the virtual sphere rolling on the cardboard. Providing haptic feedback through the considered wearable device significantly improved the performance of all the considered tasks. Moreover, subjects significantly preferred conditions providing wearable haptic feedback.

  2. Experimental Investigation and Modeling of Scale Effects in Micro Jet Pumps

    NASA Astrophysics Data System (ADS)

    Gardner, William Geoffrey

    2011-12-01

    Since the mid-1990s there has been an active effort to develop hydrocarbon-fueled power generation and propulsion systems on the scale of centimeters or smaller. This effort led to the creation and expansion of a field of research focused around the design and reduction to practice of Power MEMS (microelectromechanical systems) devices, beginning first with microscale jet engines and a generation later more broadly encompassing MEMS devices which generate power or pump heat. Due to small device scale and fabrication techniques, design constraints are highly coupled and conventional solutions for device requirements may not be practicable. This thesis describes the experimental investigation, modeling and potential applications for two classes of microscale jet pumps: jet ejectors and jet injectors. These components pump fluids with no moving parts and can be integrated into Power MEMS devices to satisfy pumping requirements by supplementing or replacing existing solutions. This thesis presents models developed from first principles which predict losses experienced at small length scales and agree well with experimental results. The models further predict maximum achievable power densities at the onset of detrimental viscous losses.

  3. Defect and grain boundary scattering in tungsten: A combined theoretical and experimental study

    NASA Astrophysics Data System (ADS)

    Lanzillo, Nicholas A.; Dixit, Hemant; Milosevic, Erik; Niu, Chengyu; Carr, Adra V.; Oldiges, Phil; Raymond, Mark V.; Cho, Jin; Standaert, Theodorus E.; Kamineni, Vimal K.

    2018-04-01

    Several major electron scattering mechanisms in tungsten (W) are evaluated using a combination of first-principles density functional theory, a Non-Equilibrium Green's Function formalism, and thin film Kelvin 4-point sheet resistance measurements. The impact of grain boundary scattering is found to be roughly an order of magnitude larger than the impact of defect scattering. Ab initio simulations predict average grain boundary reflection coefficients for a number of twin grain boundaries to lie in the range r = 0.47 to r = 0.62, while experimental data can be fit to the empirical Mayadas-Schatzkes model with a comparable but slightly larger value of r = 0.69. The experimental and simulation data for grain boundary resistivity as a function of grain size show excellent agreement. These results provide crucial insights for understanding the impact of scaling of W-based contacts between active devices and back-end-of-line interconnects in next-generation semiconductor technology.

  4. Studies on in-vessel debris coolability in ALPHA program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maruyama, Yu; Yamano, Norihiro; Moriyama, Kiyofumi

    1997-02-01

    In-vessel debris coolability experiments have been performed in ALPHA Program at JAERI. Aluminum oxide (Al{sub 2}O{sub 3}) produced by a thermite reaction was applied as a debris simulant. Two scoping experiments using approximately 30 kg or 50 kg of Al{sub 2}O{sub 3} were conducted. In addition to post-test observations, temperature histories of the debris simulant and the lower head experimental vessel were evaluated. Rapid temperature reduction observed on the outer surface of the experimental vessel may imply that water penetration into a gap between the solidified debris and the experimental vessel occurred resulting in an effective cooling of once heatedmore » vessel wall. Preliminary measurement of a gap width was made with an ultrasonic device. Signals to show the existence of gaps, ranging from 0.7 mm to 1.4 mm, were detected at several locations.« less

  5. Inducer Hydrodynamic Load Measurement Devices

    NASA Technical Reports Server (NTRS)

    Skelley, Stephen E.; Zoladz, Thomas F.

    2002-01-01

    Marshall Space Flight Center (MSFC) has demonstrated two measurement devices for sensing and resolving the hydrodynamic loads on fluid machinery. The first - a derivative of the six component wind tunnel balance - senses the forces and moments on the rotating device through a weakened shaft section instrumented with a series of strain gauges. This "rotating balance" was designed to directly measure the steady and unsteady hydrodynamic loads on an inducer, thereby defining both the amplitude and frequency content associated with operating in various cavitation modes. The second device - a high frequency response pressure transducer surface mounted on a rotating component - was merely an extension of existing technology for application in water. MSFC has recently completed experimental evaluations of both the rotating balance and surface-mount transducers in a water test loop. The measurement bandwidth of the rotating balance was severely limited by the relative flexibility of the device itself, resulting in an unexpectedly low structural bending mode and invalidating the higher frequency response data. Despite these limitations, measurements confirmed that the integrated loads on the four-bladed inducer respond to both cavitation intensity and cavitation phenomena. Likewise, the surface-mount pressure transducers were subjected to a range of temperatures and flow conditions in a non-rotating environment to record bias shifts and transfer functions between the transducers and a reference device. The pressure transducer static performance was within manufacturer's specifications and dynamic response accurately followed that of the reference.

  6. Inducer Hydrodynamic Load Measurement Devices

    NASA Technical Reports Server (NTRS)

    Skelley, Stephen E.; Zoladz, Thomas F.; Turner, Jim (Technical Monitor)

    2002-01-01

    Marshall Space Flight Center (MSFC) has demonstrated two measurement devices for sensing and resolving the hydrodynamic loads on fluid machinery. The first - a derivative of the six-component wind tunnel balance - senses the forces and moments on the rotating device through a weakened shaft section instrumented with a series of strain gauges. This rotating balance was designed to directly measure the steady and unsteady hydrodynamic loads on an inducer, thereby defining both the amplitude and frequency content associated with operating in various cavitation modes. The second device - a high frequency response pressure transducer surface mounted on a rotating component - was merely an extension of existing technology for application in water. MSFC has recently completed experimental evaluations of both the rotating balance and surface-mount transducers in a water test loop. The measurement bandwidth of the rotating balance was severely limited by the relative flexibility of the device itself, resulting in an unexpectedly low structural bending mode and invalidating the higher-frequency response data. Despite these limitations, measurements confirmed that the integrated loads on the four-bladed inducer respond to both cavitation intensity and cavitation phenomena. Likewise, the surface-mount pressure transducers were subjected to a range of temperatures and flow conditions in a non-rotating environment to record bias shifts and transfer functions between the transducers and a reference device. The pressure transducer static performance was within manufacturer's specifications and dynamic response accurately followed that of the reference.

  7. A knee-mounted biomechanical energy harvester with enhanced efficiency and safety

    NASA Astrophysics Data System (ADS)

    Chen, Chao; Chau, Li Yin; Liao, Wei-Hsin

    2017-06-01

    Energy harvesting is becoming a major limiting issue for many portable devices. When undertaking any activity, the human body generates a significant amount of biomechanical energy, which can be collected by means of a portable energy harvester. This energy provides a method of powering portable devices such as prosthetic limbs. In this paper, a knee-mounted energy harvester with enhanced efficiency and safety is proposed and developed to convert mechanical energy into electricity during human motion. This device can change the bi-directional knee input into uni-directional rotation for an electromagnetic generator using a specially designed transmission system. Without the constraint of induced impact on the human body, this device can harvest biomechanical energy from both knee flexion and extension, improving the harvesting efficiency over previous single-direction energy harvesters. It can also provide protection from device malfunction, and increase the safety of current biomechanical energy harvesters. A highly compact and light prototype is developed taking into account human kinematics. The biomechanical energy harvesting system is also modeled and analyzed. The prototype is tested under different conditions including walking, running and climbing stairs, to evaluate the energy harvesting performance and effect on the human gait. The experimental results show that the prototype can harvest an average power of 3.6 W at 1.5 m s-1 walking speed, which is promising for portable electronic devices.

  8. An experimental facility for the visual study of turbulent flows.

    NASA Technical Reports Server (NTRS)

    Brodkey, R. S.; Hershey, H. C.; Corino, E. R.

    1971-01-01

    An experimental technique which allows visual observations of the wall area in turbulent pipe flow is described in detail. It requires neither the introduction of any injection or measuring device into the flow nor the presence of a two-phase flow or of a non-Newtonian fluid. The technique involves suspending solid MgO particles of colloidal size in trichloroethylene and photographing their motions near the wall with a high speed movie camera moving with the flow. Trichloroethylene was chosen in order to eliminate the index of refraction problem in a curved wall. Evaluation of the technique including a discussion of limitations is included. Also the technique is compared with previous methods of visual observations of turbulent flow.

  9. Characterization of gamma field in the JSI TRIGA reactor

    NASA Astrophysics Data System (ADS)

    Ambrožič, Klemen; Radulović, Vladimir; Snoj, Luka; Gruel, Adrien; Guillou, Mael Le; Blaise, Patrick; Destouches, Christophe; Barbot, Loïc

    2018-01-01

    Research reactors such as the "Jožzef Stefan" Institute TRIGA reactor have primarily been designed for experimentation and sample irradiation with neutrons. However recent developments in incorporating additional instrumentation for nuclear power plant support and with novel high flux material testing reactor designs, γ field characterization has become of great interest for the characterization of the changes in operational parameters of electronic devices and for the evaluation of γ heating of MTR's structural materials in a representative reactor Γ spectrum. In this paper, we present ongoing work on γ field characterization both experimentally, by performing γ field measurements, and by simulations, using Monte Carlo particle transport codes in conjunction with R2S methodology for delayed γ field characterization.

  10. [The evaluation of pharmacological drugs, medical devices, and non-pharmacological or public health interventions: Experimental design limitations. Moving towards new methods?

    PubMed

    Villeval, M; Carayol, M; Lamy, S; Lepage, B; Lang, T

    2016-12-01

    In the field of health, evidence-based medicine and associated methods like randomised controlled trials (RCTs) have become widely used. RCT has become the gold standard for evaluating causal links between interventions and health results. Originating in pharmacology, this method has been progressively expanded to medical devices, non-pharmacological individual interventions, as well as collective public health interventions. Its use in these domains has led to the formulation of several limits, and it has been called into question as an undisputed gold standard. Some of those limits (e.g. confounding biases and external validity) are common to these four different domains, while others are more specific. This paper describes the different limits, as well as several research avenues. Some are methodological reflections aiming at adapting RCT to the complexity of the tested interventions, and at overcoming some of its limits. Others are alternative methods. The objective is not to remove RCT from the range of evaluation methodologies, but to resituate it within this range. The aim is to encourage choosing between different methods according to the features and the level of the intervention to evaluate, thereby calling for methodological pluralism. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  11. Design and characterization of hydrogel-based microfluidic devices with biomimetic solute transport networks

    PubMed Central

    Koo, Hyung-Jun

    2017-01-01

    Hydrogel could serve as a matrix material of new classes of solar cells and photoreactors with embedded microfluidic networks. These devices mimic the structure and function of plant leaves, which are a natural soft matter based microfluidic system. These unusual microfluidic-hydrogel devices with fluid-penetrable medium operate on the basis of convective-diffusive mechanism, where the liquid is transported between the non-connected channels via molecular permeation through the hydrogel. We define three key designs of such hydrogel devices, having linear, T-shaped, and branched channels and report results of numerical simulation of the process of their infusion with solute carried by the incoming fluid. The computational procedure takes into account both pressure-driven convection and concentration gradient-driven diffusion in the permeable gel matrix. We define the criteria for evaluation of the fluid infusion rate, uniformity, solute loss by outflow and overall performance. The T-shaped channel network was identified as the most efficient one and was improved further by investigating the effect of the channel-end secondary branches. Our parallel experimental data on the pattern of solute infusions are in excellent agreement with the simulation. These network designs can be applied to a broad range of novel microfluidic materials and soft matter devices with distributed microchannel networks. PMID:28396708

  12. Chemical sensors for breath gas analysis: the latest developments at the Breath Analysis Summit 2013.

    PubMed

    Tisch, Ulrike; Haick, Hossam

    2014-06-01

    Profiling the body chemistry by means of volatile organic compounds (VOCs) in the breath opens exciting new avenues in medical diagnostics. Gas sensors could provide ideal platforms for realizing portable, hand-held breath testing devices in the near future. This review summarizes the latest developments and applications in the field of chemical sensors for diagnostic breath testing that were presented at the Breath Analysis Summit 2013 in Wallerfangen, Germany. Considerable progress has been made towards clinically applicable breath testing devices, especially by utilizing chemo-sensitive nanomaterials. Examples of several specialized breath testing applications are presented that are either based on stand-alone nanomaterial-based sensors being highly sensitive and specific to individual breath compounds over others, or on combinations of several highly specific sensors, or on experimental nanomaterial-based sensors arrays. Other interesting approaches include the adaption of a commercially available MOx-based sensor array to indirect breath testing applications, using a sample pre-concentration method, and the development of compact integrated GC-sensor systems. The recent trend towards device integration has led to the development of fully integrated prototypes of point-of-care devices. We describe and compare the performance of several prototypes that are based on different sensing technologies and evaluate their potential as low-cost and readily available next-generation medical devices.

  13. Preclinical in vivo long-term evaluation of the novel Mitra-Spacer technology: experimental validation in the ovine model.

    PubMed

    Peppas, Athanasios; Furer, Ariel; Wilson, Jon; Yi, GengHua; Cheng, Yanping; Van Wygerden, Karl; Seguin, Christopher; Shibuya, Masahiko; Kaluza, Grzegorz L; Granada, Juan F

    2017-06-20

    The Mitra-Spacer (Cardiosolutions, Bridgewater, MA, USA) is designed to treat mitral regurgitation by introducing a dynamic spacer that constantly adapts to the changing haemodynamic conditions during the cardiac cycle. We aimed to evaluate the performance and safety of this device in the chronic ovine model. Eight sheep were enrolled in this study. Through a left thoracotomy, the Mitra-Spacer was inserted via the transapical approach and advanced into the left atrium (LA) under imaging guidance. Device performance and safety were evaluated up to 90 days using fluoroscopy, echocardiography and histopathology. The volume within the balloon spacer shifted during the cardiac cycle in all cases. Seven animals survived up to 90 days for terminal imaging and tissue harvest. Echocardiography showed no change in left ventricle (LV) ejection fraction from baseline to 90 days. There were no observations of changes in LV diastolic function, pulmonary vein inflow, or tricuspid valve function. Histological analysis demonstrated no significant injury to the mitral apparatus. In the healthy ovine model, Mitra-Spacer implantation was feasible and safe. At 90 days, no evidence of structural damage to the mitral apparatus or deterioration of cardiac performance was demonstrated.

  14. Generating Students' Information Seeking Questions in the Scholar Lab: What Benefits Can We Expect from Inquiry Teaching Approaches?

    ERIC Educational Resources Information Center

    Torres, Tarcilo; Milicic, Beatriz; Soto, Carlos; Sanjose, Vicente

    2013-01-01

    Physics teachers use experimental devices to show students how scientific concepts, principles, and laws are applied to understand the real world. This paper studies question generation of secondary and under-graduate university students when they are confronted with experimental devices in different but usual teaching situations: reading about…

  15. Textbooks on tap: using electronic books housed in handheld devices in nursing clinical courses.

    PubMed

    Williams, Margaret G; Dittmer, Arlis

    2009-01-01

    Changing technology is creating new ways to approach nursing education and practice. Beginning in 2003, using a quasi-experimental design, this project introduced personal digital assistants (PDAs) as a clinical tool to five experimental and control groups of students and faculty. The handheld device, or PDA, was loaded with e-books for clinical practice. Differences in learning styles and preferences emerged during the different phases of the study. Students were quickly able to master the technology and use the device effectively, reporting that they liked the concise nature of the information obtained. No students expressed dissatisfaction or regret at being in the experimental group. Results and implications for clinical practice, education, and library resources are discussed.

  16. Experimental generation of Laguerre-Gaussian beam using digital micromirror device.

    PubMed

    Ren, Yu-Xuan; Li, Ming; Huang, Kun; Wu, Jian-Guang; Gao, Hong-Fang; Wang, Zi-Qiang; Li, Yin-Mei

    2010-04-01

    A digital micromirror device (DMD) modulates laser intensity through computer control of the device. We experimentally investigate the performance of the modulation property of a DMD and optimize the modulation procedure through image correction. Furthermore, Laguerre-Gaussian (LG) beams with different topological charges are generated by projecting a series of forklike gratings onto the DMD. We measure the field distribution with and without correction, the energy of LG beams with different topological charges, and the polarization property in sequence. Experimental results demonstrate that it is possible to generate LG beams with a DMD that allows the use of a high-intensity laser with proper correction to the input images, and that the polarization state of the LG beam differs from that of the input beam.

  17. Towards understanding addiction factors of mobile devices: An eye tracking study on effect of screen size.

    PubMed

    Wibirama, Sunu; Nugroho, Hanung A

    2017-07-01

    Mobile devices addiction has been an important research topic in cognitive science, mental health, and human-machine interaction. Previous works observed mobile device addiction by logging mobile devices activity. Although immersion has been linked as a significant predictor of video game addiction, investigation on addiction factors of mobile device with behavioral measurement has never been done before. In this research, we demonstrated the usage of eye tracking to observe effect of screen size on experience of immersion. We compared subjective judgment with eye movements analysis. Non-parametric analysis on immersion score shows that screen size affects experience of immersion (p<;0.05). Furthermore, our experimental results suggest that fixational eye movements may be used as an indicator for future investigation of mobile devices addiction. Our experimental results are also useful to develop a guideline as well as intervention strategy to deal with smartphone addiction.

  18. Fabrication of flexible, multimodal light-emitting devices for wireless optogenetics

    PubMed Central

    Huang, Xian; Jung, Yei Hwan; Al-Hasani, Ream; Omenetto, Fiorenzo G.

    2014-01-01

    Summary The rise of optogenetics provides unique opportunities to advance materials and biomedical engineering as well as fundamental understanding in neuroscience. This protocol describes the fabrication of optoelectronic devices for studying intact neural systems. Unlike optogenetic approaches that rely on rigid fiber optics tethered to external light sources, these novel devices utilize flexible substrates to carry wirelessly powered microscale, inorganic light-emitting diodes (μ-ILEDs) and multimodal sensors inside the brain. We describe the technical procedures for construction of these devices, their corresponding radiofrequency power scavengers, and their implementation in vivo for experimental application. In total, the timeline of the procedure, including device fabrication, implantation, and preparation to begin in vivo experimentation, can be completed in approximately 3–8 weeks. Implementation of these devices allows for chronic (tested up to six months), wireless optogenetic manipulation of neural circuitry in animals experiencing behaviors such as social interaction, home cage, and other complex natural environments. PMID:24202555

  19. Nonlinear Characterization of Half and Full Wavelength Power Ultrasonic Devices

    NASA Astrophysics Data System (ADS)

    Mathieson, Andrew; Cerisola, Niccolò; Cardoni, Andrea

    It is well known that power ultrasonic devices whilst driven under elevated excitation levels exhibit nonlinear behaviors. If no attempt is made to understand and subsequently control these behaviors, these devices can exhibit poor performance or even suffer premature failure. This paper presents an experimental method for the dynamic characterization of a commercial ultrasonic transducer for bone cutting applications (Piezosurgery® Device) operated together with a variety of rod horns that are tuned to operate in a longitudinal mode of vibration. Near resonance responses, excited via a burst sine sweep method were used to identify nonlinear responses exhibited by the devices, while experimental modal analysis was performed to identify the modal parameters of the longitudinal modes of vibration of the assemblies between 0-80 kHz. This study tries to provide an understanding of the effects that geometry and material choices may have on the nonlinear behavior of a tuned device.

  20. Is there any evidence that cerebral protection is beneficial? Experimental data.

    PubMed

    Macdonald, S

    2006-04-01

    This article presents the available experimental data from the world literature on the use of cerebral protection devices during carotid artery stenting (CAS). Clinical studies relying on surrogate markers of cerebral embolisation in place of neurological event rate as primary outcome measures are evaluated alongside bench-top and animal studies. These surrogate markers include evaluations of outcomes using procedural transcranial Doppler (TCD) and diffusion-weighted magnetic resonance imaging of brain (DWI). Pathological analyses of debris retrieved from in-vivo analyses of protection devices are also included in this review because although the focus of these studies was primarily clinical, the laboratory data will be preferentially presented and it provides interesting insights. It can be shown that each of the three philosophies of cerebral protection, namely flow arrest (proximal or distal), flow reversal and distal filtration is capable of the entrapment of sizeable debris that would logically threaten devastating stroke if it embolized to the brain. Whilst balloon occlusion significantly reduces the procedural microembolic load (particles less than 60 mm) and flow reversal may be the first means to entirely eliminate it, filters may be associated with increased microembolization. This has been described by some workers as controlled embolization. Certainly, particles smaller than the pore size of currently available filters (60-140 mm) will readily evade capture due to filter periflow and through-flow. There is evidence to suggest that tens of thousands of particles of this size may be released during CAS and there is some evidence that this may be associated with more new white lesions on DWI of brain. The clinical consequences of this controlled embolization however, remain unclear and sophisticated neuropsychometric test batteries may need to be applied at later time points to detect subtle injury that may be compounded by a late inflammatory response around cerebral emboli. Devices relying on placement in the distal internal carotid artery (ICA) for establishment of protection risk intimal damage and the release of microemboli due largely to device deployment and retrieval. Although devices effecting flow arrest and flow reversal will limit all embolization, they do so at the expense of constant procedural cerebral perfusion and may not be tolerated in patients with precarious cerebral reserve capacity, loss of integrity of the Circle of Willis and/or high-grade stenosis of the contralateral ICA. Advances in the concept of cerebral protection will require technical refinements to existing devices, alternative mechanical strategies and/or pharmacological plaque stabilization.

  1. Multi-depth valved microfluidics for biofilm segmentation

    NASA Astrophysics Data System (ADS)

    Meyer, M. T.; Subramanian, S.; Kim, Y. W.; Ben-Yoav, H.; Gnerlich, M.; Gerasopoulos, K.; Bentley, W. E.; Ghodssi, R.

    2015-09-01

    Bacterial biofilms present a societal challenge, as they occur in the majority of infections but are highly resistant to both immune mechanisms and traditional antibiotics. In the pursuit of better understanding biofilm biology for developing new treatments, there is a need for streamlined, controlled platforms for biofilm growth and evaluation. We leverage advantages of microfluidics to develop a system in which biofilms are formed and sectioned, allowing parallel assays on multiple sections of one biofilm. A microfluidic testbed with multiple depth profiles was developed to accommodate biofilm growth and sectioning by hydraulically actuated valves. In realization of the platform, a novel fabrication technique was developed for creating multi-depth microfluidic molds using sequentially patterned photoresist separated and passivated by conformal coatings using atomic layer deposition. Biofilm thickness variation within three separately tested devices was less than 13% of the average thickness in each device, while variation between devices was 23% of the average thickness. In a demonstration of parallel experiments performed on one biofilm within one device, integrated valves were used to trisect the uniform biofilms with one section maintained as a control, and two sections exposed to different concentrations of sodium dodecyl sulfate. The technology presented here for multi-depth microchannel fabrication can be used to create a host of microfluidic devices with diverse architectures. While this work focuses on one application of such a device in biofilm sectioning for parallel experimentation, the tailored architectures enabled by the fabrication technology can be used to create devices that provide new biological information.

  2. Guest concentration, bias current, and temperature-dependent sign inversion of magneto-electroluminescence in thermally activated delayed fluorescence devices

    NASA Astrophysics Data System (ADS)

    Deng, Junquan; Jia, Weiyao; Chen, Yingbing; Liu, Dongyu; Hu, Yeqian; Xiong, Zuhong

    2017-03-01

    Non-emissive triplet excited states in devices that undergo thermally activated delayed fluorescence (TADF) can be up-converted to singlet excited states via reverse intersystem crossing (RISC), which leads to an enhanced electroluminescence efficiency. Exciton-based fluorescence devices always exhibit a positive magneto-electroluminescence (MEL) because intersystem crossing (ISC) can be suppressed effectively by an external magnetic field. Conversely, TADF devices should exhibit a negative MEL because RISC is suppressed by the external magnetic field. Intriguingly, we observed a positive MEL in TADF devices. Moreover, the sign of the MEL was either positive or negative, and depended on experimental conditions, including doping concentration, current density and temperature. The MEL observed from our TADF devices demonstrated that ISC in the host material and RISC in the guest material coexisted. These competing processes were affected by the experimental conditions, which led to the sign change of the MEL. This work gives important insight into the energy transfer processes and the evolution of excited states in TADF devices.

  3. Quantifying redox-induced Schottky barrier variations in memristive devices via in operando spectromicroscopy with graphene electrodes

    PubMed Central

    Baeumer, Christoph; Schmitz, Christoph; Marchewka, Astrid; Mueller, David N.; Valenta, Richard; Hackl, Johanna; Raab, Nicolas; Rogers, Steven P.; Khan, M. Imtiaz; Nemsak, Slavomir; Shim, Moonsub; Menzel, Stephan; Schneider, Claus Michael; Waser, Rainer; Dittmann, Regina

    2016-01-01

    The continuing revolutionary success of mobile computing and smart devices calls for the development of novel, cost- and energy-efficient memories. Resistive switching is attractive because of, inter alia, increased switching speed and device density. On electrical stimulus, complex nanoscale redox processes are suspected to induce a resistance change in memristive devices. Quantitative information about these processes, which has been experimentally inaccessible so far, is essential for further advances. Here we use in operando spectromicroscopy to verify that redox reactions drive the resistance change. A remarkable agreement between experimental quantification of the redox state and device simulation reveals that changes in donor concentration by a factor of 2–3 at electrode-oxide interfaces cause a modulation of the effective Schottky barrier and lead to >2 orders of magnitude change in device resistance. These findings allow realistic device simulations, opening a route to less empirical and more predictive design of future memory cells. PMID:27539213

  4. Quantifying redox-induced Schottky barrier variations in memristive devices via in operando spectromicroscopy with graphene electrodes.

    PubMed

    Baeumer, Christoph; Schmitz, Christoph; Marchewka, Astrid; Mueller, David N; Valenta, Richard; Hackl, Johanna; Raab, Nicolas; Rogers, Steven P; Khan, M Imtiaz; Nemsak, Slavomir; Shim, Moonsub; Menzel, Stephan; Schneider, Claus Michael; Waser, Rainer; Dittmann, Regina

    2016-08-19

    The continuing revolutionary success of mobile computing and smart devices calls for the development of novel, cost- and energy-efficient memories. Resistive switching is attractive because of, inter alia, increased switching speed and device density. On electrical stimulus, complex nanoscale redox processes are suspected to induce a resistance change in memristive devices. Quantitative information about these processes, which has been experimentally inaccessible so far, is essential for further advances. Here we use in operando spectromicroscopy to verify that redox reactions drive the resistance change. A remarkable agreement between experimental quantification of the redox state and device simulation reveals that changes in donor concentration by a factor of 2-3 at electrode-oxide interfaces cause a modulation of the effective Schottky barrier and lead to >2 orders of magnitude change in device resistance. These findings allow realistic device simulations, opening a route to less empirical and more predictive design of future memory cells.

  5. Quantifying redox-induced Schottky barrier variations in memristive devices via in operando spectromicroscopy with graphene electrodes

    NASA Astrophysics Data System (ADS)

    Baeumer, Christoph; Schmitz, Christoph; Marchewka, Astrid; Mueller, David N.; Valenta, Richard; Hackl, Johanna; Raab, Nicolas; Rogers, Steven P.; Khan, M. Imtiaz; Nemsak, Slavomir; Shim, Moonsub; Menzel, Stephan; Schneider, Claus Michael; Waser, Rainer; Dittmann, Regina

    2016-08-01

    The continuing revolutionary success of mobile computing and smart devices calls for the development of novel, cost- and energy-efficient memories. Resistive switching is attractive because of, inter alia, increased switching speed and device density. On electrical stimulus, complex nanoscale redox processes are suspected to induce a resistance change in memristive devices. Quantitative information about these processes, which has been experimentally inaccessible so far, is essential for further advances. Here we use in operando spectromicroscopy to verify that redox reactions drive the resistance change. A remarkable agreement between experimental quantification of the redox state and device simulation reveals that changes in donor concentration by a factor of 2-3 at electrode-oxide interfaces cause a modulation of the effective Schottky barrier and lead to >2 orders of magnitude change in device resistance. These findings allow realistic device simulations, opening a route to less empirical and more predictive design of future memory cells.

  6. 42 CFR 405.753 - Appeal of a categorization of a device.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 2 2011-10-01 2011-10-01 false Appeal of a categorization of a device. 405.753... Under Medicare Part A § 405.753 Appeal of a categorization of a device. (a) CMS's acceptance of the FDA categorization of a device as an experimental/investigational (Category A) device under § 405.203 is a national...

  7. 42 CFR 405.877 - Appeal of a categorization of a device.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 2 2010-10-01 2010-10-01 false Appeal of a categorization of a device. 405.877... Part B Program § 405.877 Appeal of a categorization of a device. (a) CMS's acceptance of the FDA categorization of a device as an experimental/investigational (Category A) device under § 405.203 is a national...

  8. 42 CFR 405.877 - Appeal of a categorization of a device.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 2 2011-10-01 2011-10-01 false Appeal of a categorization of a device. 405.877... Part B Program § 405.877 Appeal of a categorization of a device. (a) CMS's acceptance of the FDA categorization of a device as an experimental/investigational (Category A) device under § 405.203 is a national...

  9. 42 CFR 405.753 - Appeal of a categorization of a device.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 2 2010-10-01 2010-10-01 false Appeal of a categorization of a device. 405.753... Under Medicare Part A § 405.753 Appeal of a categorization of a device. (a) CMS's acceptance of the FDA categorization of a device as an experimental/investigational (Category A) device under § 405.203 is a national...

  10. Josephson junction as the receiving and measuring element in panoramic receiver: frequencymeter in terahertz band

    NASA Astrophysics Data System (ADS)

    Denisov, Alexander; Gudkov, Alexander; Qiu, Jing Hui

    2014-10-01

    Josephson junction (JJ) can be used as the criterion in single-block super wide band frequency-meter and as the sensitive element in the super wide band panoramic receiver. There presented the theoretical and experimental investigations and described the innovation decision about to combine both devices in one new microwave device. JJ in this case works in self-pump mode regime. New device can be especially convenient for the experimental purposes with new generation structures when radiated power is small and frequency are unknown correctly.

  11. EXPERIMENTAL ANIMAL WATERING DEVICE

    DOEpatents

    Finkel, M.P.

    1964-04-01

    A device for watering experimental animals confined in a battery of individual plastic enclosures is described. It consists of a rectangular plastic enclosure having a plurality of fluid-tight compartments, each with a drinking hole near the bottom and a filling hole on the top. The enclosure is immersed in water until filled, its drinking holes sealed with a strip of tape, and it is then placed in the battery. The tape sealing prevents the flow of water from the device, but permits animals to drink by licking the drinking holes. (AEC)

  12. The EPICS-based remote control system for muon beam line devices at J-PARC MUSE

    NASA Astrophysics Data System (ADS)

    Ito, T. U.; Nakahara, K.; Kawase, M.; Fujimori, H.; Kobayashi, Y.; Higemoto, W.; Miyake, Y.

    2010-04-01

    The remote control system for muon beam line devices of J-PARC MUSE has been developed with the Experimental Physics and Industrial Control System (EPICS). The EPICS input/output controller was installed in standard Linux PCs for slow control of the devices. Power supplies for 21 magnetic elements and four slit controllers for the decay-surface muon beam line in the Materials and Life Science Experimental Facility are now accessible via Ethernet from a graphical user interface which has been composed using the Motif Editor and Display Manger.

  13. Optical properties of electrically connected plasmonic nanoantenna dimer arrays

    NASA Astrophysics Data System (ADS)

    Zimmerman, Darin T.; Borst, Benjamin D.; Carrick, Cassandra J.; Lent, Joseph M.; Wambold, Raymond A.; Weisel, Gary J.; Willis, Brian G.

    2018-02-01

    We fabricate electrically connected gold nanoantenna arrays of homodimers and heterodimers on silica substrates and present a systematic study of their optical properties. Electrically connected arrays of plasmonic nanoantennas make possible the realization of novel photonic devices, including optical sensors and rectifiers. Although the plasmonic response of unconnected arrays has been studied extensively, the present study shows that the inclusion of nanowire connections modifies the device response significantly. After presenting experimental measurements of optical extinction for unconnected dimer arrays, we compare these to measurements of dimers that are interconnected by gold nanowire "busbars." The connected devices show the familiar dipole response associated with the unconnected dimers but also show a second localized surface plasmon resonance (LSPR) that we refer to as the "coupled-busbar mode." Our experimental study also demonstrates that the placement of the nanowire along the antenna modifies the LSPR. Using finite-difference time-domain simulations, we confirm the experimental results and investigate the variation of dimer gap and spacing. Changing the dimer gap in connected devices has a significantly smaller effect on the dipole response than it does in unconnected devices. On the other hand, both LSPR modes respond strongly to changing the spacing between devices in the direction along the interconnecting wires. We also give results for the variation of E-field strength in the dimer gap, which will be important for any working sensor or rectenna device.

  14. Experimental and numerical studies of a microfluidic device with compliant chambers for flow stabilization

    NASA Astrophysics Data System (ADS)

    Iyer, V.; Raj, A.; Annabattula, R. K.; Sen, A. K.

    2015-07-01

    This paper reports experimental and numerical studies of a passive microfluidic device that stabilizes a pulsating incoming flow and delivers a steady flow at the outlet. The device employs a series of chambers along the flow direction with a thin polymeric membrane (of thickness 75-250 µm) serving as the compliant boundary. The deformation of the membrane allows accumulation of fluid during an overflow and discharge of fluid during an underflow for flow stabilization. Coupled fluid-structure simulations are performed using Mooney-Rivlin formulations to account for a thin hyperelastic membrane material undergoing large deformations to accurately predict the device performance. The device was fabricated with PDMS as the substrate material and thin PDMS membrane as the compliant boundary. The performance of the device is defined in terms of a parameter called ‘Attenuation Factor (AF)’. The effect of various design parameters including membrane thickness, elastic modulus, chamber size and number of chambers in series as well as operating conditions including the outlet pressure, mean input flow rate, fluctuation amplitude and frequency on the device performance were studied using experiments and simulations. The simulation results successfully confront the experimental data (within 10%) which validates the numerical simulations. The device was used at the exit of a PZT actuated valveless micropump to take pulsating flow at the upstream and deliver steady flow downstream. The amplitude of the pulsating flow delivered by the micropump was significantly reduced (AF = 0.05 for a device with three 4 mm chambers) but at the expense of a reduction in the pressure capability (<20%). The proposed device could potentially be used for reducing flow pulsations in practical microfluidic circuits.

  15. The sustaining effect of three polymers on the release of chlorhexidine from a controlled release drug device for root canal disinfection.

    PubMed

    Lee, Doug-Youn; Spångberg, Larz S W; Bok, Young-Bin; Lee, Chang-Young; Kum, Kee-Yeon

    2005-07-01

    The aim of this in vitro study was to evaluate the suitability of using chitosan, poly (lactide-co-glycolide) (PLGA), and polymethyl methacrylate (PMMA) to control the release of chlorhexidine digluconate (CHX) from a prototype of controlled release drug device for root canal disinfection. Four different prototypes with different formulations were prepared. Group A (n = 12): the device (absorbent paper point) was loaded with CHX as control. Group B (n = 12): same as group A, but the device was coated with chitosan (Texan MedTech). In Groups C and D, the device was treated in the same way as group A and then coated 3 times with 5% PMMA (Group C, n = 12, Aldrich), or coated 3 times with 3% PLGA (Group D, n = 12, Sigma). The devices were randomly allocated to experimental groups of 12 each. All the prototypes of controlled release drug device were soaked in 3 mL distilled water. The concentrations of CHX were determined using a UV spectrophotometer. The surface characteristics of each prototype were observed using a scanning electron microscope. The result showed that release rate of CHX was the greatest in the noncoated group, followed by the chitosan-coated group, the PLGA-coated group, and the PMMA-coated group (P < 0.05). Pores were observed on the surface of the prototypes that were coated with PLGA and PMMA. When the pore size was smaller, the release rate was lower. These data indicate that polymer coating can control the release rate of CHX from the prototypes of controlled release drug device.

  16. [Industry regulation and its relationship to the rapid marketing of medical devices].

    PubMed

    Matsuoka, Atsuko

    2012-01-01

    In the market of medical devices, non-Japanese products hold a large part even in Japan. To overcome this situation, the Japanese government has been announcing policies to encourage the medical devices industry, such as the 5-year strategy for medical innovation (June 6, 2012). The Division of Medical Devices has been contributing to rapid marketing of medical devices by working out the standards for approval review and accreditation of medical devices, guidances on evaluation of medical devices with emerging technology, and test methods for biological safety evaluation of medical devices, as a part of practice in the field of regulatory science. The recent outcomes are 822 standards of accreditation for Class II medical devices, 14 guidances on safety evaluation of medical devices with emerging technology, and the revised test methods for biological safety evaluation (MHLW Notification by Director, OMDE, Yakushokuki-hatsu 0301 No. 20 "Basic Principles of Biological Safety Evaluation Required for Application for Approval to Market Medical Devices").

  17. 42 CFR 405.203 - FDA categorization of investigational devices.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 2 2010-10-01 2010-10-01 false FDA categorization of investigational devices. 405... Coverage Decisions That Relate to Health Care Technology § 405.203 FDA categorization of investigational devices. (a) The FDA assigns a device with an FDA-approved IDE to one of two categories: (1) Experimental...

  18. 42 CFR 405.203 - FDA categorization of investigational devices.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 2 2014-10-01 2014-10-01 false FDA categorization of investigational devices. 405... Coverage Decisions That Relate to Health Care Technology § 405.203 FDA categorization of investigational devices. (a) The FDA assigns a device with an FDA-approved IDE to one of two categories: (1) Experimental...

  19. 42 CFR 405.203 - FDA categorization of investigational devices.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 2 2013-10-01 2013-10-01 false FDA categorization of investigational devices. 405... Coverage Decisions That Relate to Health Care Technology § 405.203 FDA categorization of investigational devices. (a) The FDA assigns a device with an FDA-approved IDE to one of two categories: (1) Experimental...

  20. 42 CFR 405.203 - FDA categorization of investigational devices.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 2 2011-10-01 2011-10-01 false FDA categorization of investigational devices. 405... Coverage Decisions That Relate to Health Care Technology § 405.203 FDA categorization of investigational devices. (a) The FDA assigns a device with an FDA-approved IDE to one of two categories: (1) Experimental...

  1. 42 CFR 405.203 - FDA categorization of investigational devices.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 2 2012-10-01 2012-10-01 false FDA categorization of investigational devices. 405... Coverage Decisions That Relate to Health Care Technology § 405.203 FDA categorization of investigational devices. (a) The FDA assigns a device with an FDA-approved IDE to one of two categories: (1) Experimental...

  2. Design and evaluation of a computed tomography (CT)-compatible needle insertion device using an electromagnetic tracking system and CT images.

    PubMed

    Shahriari, Navid; Hekman, Edsko; Oudkerk, Matthijs; Misra, Sarthak

    2015-11-01

    Percutaneous needle insertion procedures are commonly used for diagnostic and therapeutic purposes. Although current technology allows accurate localization of lesions, they cannot yet be precisely targeted. Lung cancer is the most common cause of cancer-related death, and early detection reduces the mortality rate. Therefore, suspicious lesions are tested for diagnosis by performing needle biopsy. In this paper, we have presented a novel computed tomography (CT)-compatible needle insertion device (NID). The NID is used to steer a flexible needle (φ0.55 mm) with a bevel at the tip in biological tissue. CT images and an electromagnetic (EM) tracking system are used in two separate scenarios to track the needle tip in three-dimensional space during the procedure. Our system uses a control algorithm to steer the needle through a combination of insertion and minimal number of rotations. Noise analysis of CT images has demonstrated the compatibility of the device. The results for three experimental cases (case 1: open-loop control, case 2: closed-loop control using EM tracking system and case 3: closed-loop control using CT images) are presented. Each experimental case is performed five times, and average targeting errors are 2.86 ± 1.14, 1.11 ± 0.14 and 1.94 ± 0.63 mm for case 1, case 2 and case 3, respectively. The achieved results show that our device is CT-compatible and it is able to steer a bevel-tipped needle toward a target. We are able to use intermittent CT images and EM tracking data to control the needle path in a closed-loop manner. These results are promising and suggest that it is possible to accurately target the lesions in real clinical procedures in the future.

  3. Evaluation of microtensile bond strength of self-etching adhesives on normal and caries-affected dentin.

    PubMed

    Shibata, Shizuma; Vieira, Luiz Clovis Cardoso; Baratieri, Luiz Narciso; Fu, Jiale; Hoshika, Shuhei; Matsuda, Yasuhiro; Sano, Hidehiko

    2016-01-01

    The purpose of this study was to evaluate the µTBS (microtensile bond strength) of currently available self-etching adhesives with an experimental self-etch adhesive in normal and caries-affected dentin, using a portable hardness measuring device, in order to standardize dentin Knoop hardness. Normal (ND) and caries-affected dentin (CAD) were obtained from twenty human molars with class II natural caries. The following adhesive systems were tested: Mega Bond (MB), a 2-step self-etching adhesive; MTB-200 (MTB), an experimental 1-step self-etching adhesive (1-SEA), and two commercially available one-step self-etching systems, G-Bond Plus (GB) and Adper Easy Bond (EB). MB-ND achieved the highest µTBS (p<0.05). The mean µTBS was statistically lower in CAD than in ND for all adhesives tested (p<0.05), and the 2-step self-etch adhesive achieved better overall performance than the 1-step self-etch adhesives.

  4. Experimental and in silico investigations of organic phosphates and phosphonates sorption on polymer-ceramic monolithic materials and hydroxyapatite.

    PubMed

    Pietrzyńska, Monika; Zembrzuska, Joanna; Tomczak, Rafał; Mikołajczyk, Jakub; Rusińska-Roszak, Danuta; Voelkel, Adam; Buchwald, Tomasz; Jampílek, Josef; Lukáč, Miloš; Devínsky, Ferdinand

    2016-10-10

    A method based on experimental and in silico evaluations for investigating interactions of organic phosphates and phosphonates with hydroxyapatite was developed. This quick and easy method is used for determination of differences among organophosphorus compounds of various structures in their mineral binding affinities. Empirical sorption evaluation was carried out using liquid chromatography with tandem mass spectrometry or UV-VIS spectroscopy. Raman spectroscopy was used to confirm sorption of organic phosphates and phosphonates on hydroxyapatite. Polymer-ceramic monolithic material and bulk hydroxyapatite were applied as sorbent materials. Furthermore, a Polymer-ceramic Monolithic In-Needle Extraction device was used to investigate both sorption and desorption steps. Binding energies were computed from the fully optimised structures utilising Density Functional Theory (DFT) at B3LYP/6-31+G(d,p) level. Potential pharmacologic and toxic effects of the tested compounds were estimated by the Prediction of the Activity Spectra of Substances using GeneXplain software. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Evaluation of Turner relaxed state as a model of long-lived ion-trapping structures in plasma focus and Z-pinches

    NASA Astrophysics Data System (ADS)

    Auluck, S. K. H.

    2011-03-01

    Relatively long-lived spheroidal structures coincident with the neutron emission phase have been observed in frozen deuterium fiber Z-pinch and some plasma focus devices. Existence of energetic ion-trapping mechanism in plasma focus has also been inferred from experimental data. It has been conjectured that these are related phenomena. This paper applies Turner's theory [L. Turner, IEEE Trans. Plasma Sci. 14, 849 (1986)] of relaxation of a Hall magnetofluid to construct a model of these structures and ion-trapping mechanism. Turner's solution modified for a finite-length plasma is used to obtain expressions for the magnetic field, velocity, and equilibrium pressure fields and is shown to represent an entity which is simultaneously a fluid vortex, a force-free magnetic field, a confined finite-pressure plasma, a charged object, and a trapped energetic ion beam. Characteristic features expected from diagnostic experiments are evaluated and shown to resemble experimental observations.

  6. CT imaging with a mobile C-arm prototype

    NASA Astrophysics Data System (ADS)

    Cheryauka, Arvi; Tubbs, David; Langille, Vinton; Kalya, Prabhanjana; Smith, Brady; Cherone, Rocco

    2008-03-01

    Mobile X-ray imagery is an omnipresent tool in conventional musculoskeletal and soft tissue applications. The next generation of mobile C-arm systems can provide clinicians of minimally-invasive surgery and pain management procedures with both real-time high-resolution fluoroscopy and intra-operative CT imaging modalities. In this study, we research two C-arm CT experimental system configurations and evaluate their imaging capabilities. In a non-destructive evaluation configuration, the X-ray Tube - Detector assembly is stationary while an imaging object is placed on a rotating table. In a medical imaging configuration, the C-arm gantry moves around the patient and the table. In our research setting, we connect the participating devices through a Mobile X-Ray Imaging Environment known as MOXIE. MOXIE is a set of software applications for internal research at GE Healthcare - Surgery and used to examine imaging performance of experimental systems. Anthropomorphic phantom volume renderings and orthogonal slices of reconstructed images are obtained and displayed. The experimental C-arm CT results show CT-like image quality that may be suitable for interventional procedures, real-time data management, and, therefore, have great potential for effective use on the clinical floor.

  7. Fiber optic micro sensor for the measurement of tendon forces

    PubMed Central

    2012-01-01

    A fiber optic sensor developed for the measurement of tendon forces was designed, numerically modeled, fabricated, and experimentally evaluated. The sensor incorporated fiber Bragg gratings and micro-fabricated stainless steel housings. A fiber Bragg grating is an optical device that is spectrally sensitive to axial strain. Stainless steel housings were designed to convert radial forces applied to the housing into axial forces that could be sensed by the fiber Bragg grating. The metal housings were fabricated by several methods including laser micromachining, swaging, and hydroforming. Designs are presented that allow for simultaneous temperature and force measurements as well as for simultaneous resolution of multi-axis forces. The sensor was experimentally evaluated by hydrostatic loading and in vitro testing. A commercial hydraulic burst tester was used to provide uniform pressures on the sensor in order to establish the linearity, repeatability, and accuracy characteristics of the sensor. The in vitro experiments were performed in excised tendon and in a dynamic gait simulator to simulate biological conditions. In both experimental conditions, the sensor was found to be a sensitive and reliable method for acquiring minimally invasive measurements of soft tissue forces. Our results suggest that this sensor will prove useful in a variety of biomechanical measurements. PMID:23033868

  8. Biomaterials approaches to treating implant-associated osteomyelitis

    PubMed Central

    Inzana, Jason A.; Schwarz, Edward M.; Kates, Stephen L.; Awad, Hani A.

    2016-01-01

    Orthopaedic devices are the most common surgical devices associated with implant-related infections and Staphylococcus aureus (S. aureus) is the most common causative pathogen in chronic bone infections (osteomyelitis). Treatment of these chronic bone infections often involves combinations of antibiotics given systemically and locally to the affected site via a biomaterial spacer. The gold standard biomaterial for local antibiotic delivery against osteomyelitis, poly(methyl methacrylate) (PMMA) bone cement, bears many limitations. Such shortcomings include limited antibiotic release, incompatibility with many antimicrobial agents, and the need for follow-up surgeries to remove the non-biodegradable cement before surgical reconstruction of the lost bone. Therefore, extensive research pursuits are targeting alternative, biodegradable materials to replace PMMA in osteomyelitis applications. Herein, we provide an overview of the primary clinical treatment strategies and emerging biodegradable materials that may be employed for management of implant-related osteomyelitis. We performed a systematic review of experimental biomaterials systems that have been evaluated for treating established S. aureus osteomyelitis in an animal model. Many experimental biomaterials were not decisively more efficacious for infection management than PMMA when delivering the same antibiotic. However, alternative biomaterials have reduced the number of follow-up surgeries, enhanced the antimicrobial efficacy by delivering agents that are incompatible with PMMA, and regenerated bone in an infected defect. Understanding the advantages, limitations, and potential for clinical translation of each biomaterial, along with the conditions under which it was evaluated (e.g. animal model), is critical for surgeons and researchers to navigate the plethora of options for local antibiotic delivery. PMID:26724454

  9. Effect of glenoid implant design on glenohumeral stability: an experimental study.

    PubMed

    Sins, Lauranne; Tétreault, Patrice; Petit, Yvan; Nuño, Natalia; Billuart, Fabien; Hagemeister, Nicola

    2012-10-01

    Though several glenoid implants were developed over the past years, a high rate of glenoid loosening remains. This complication is linked to the glenohumeral stability, defined as humeral head translation. In an intact shoulder, this concept is ensured by all active and passive elements, particularly the labrum. Two features of a glenoid implant can be adjusted to improve the stability, or, in other words, to decrease the translations: the first is the mismatch, defined as the difference of curvature between the prosthetic head and glenoid; the second is the shape of the glenoid component. Therefore, the objective of this study was to compare the performance of 2 glenoid components (Ceraver, Roissy, France): (1) a standard design and (2) a design named "labrum design" with a superior part simulating the anatomic labrum. An experimental device was developed to evaluate forces and kinematics. The device simulated active, dynamic and continuous abduction of an entire arm. It reproduced the Scapulo-Humeral Rhythm. The labrum design was installed first. To evaluate the effect of mismatch on the glenohumeral stability, 3 humeral heads were tested, corresponding to the ones recommended by the company. The experiment was repeated for the standard design. The results obtained show a general decrease of the prosthetic head translation with the labrum design compared to the standard design. No noticeable effect of mismatch was found. A proof of concept of the interest of the artificial labrum was provided since it improved the glenohumeral stability. Copyright © 2012 Elsevier Ltd. All rights reserved.

  10. An in-depth analysis of temperature effect on DIBL in UTBB FD SOI MOSFETs based on experimental data, numerical simulations and analytical models

    NASA Astrophysics Data System (ADS)

    Pereira, A. S. N.; de Streel, G.; Planes, N.; Haond, M.; Giacomini, R.; Flandre, D.; Kilchytska, V.

    2017-02-01

    The Drain Induced Barrier Lowering (DIBL) behavior in Ultra-Thin Body and Buried oxide (UTBB) transistors is investigated in details in the temperature range up to 150 °C, for the first time to the best of our knowledge. The analysis is based on experimental data, physical device simulation, compact model (SPICE) simulation and previously published models. Contrary to MASTAR prediction, experiments reveal DIBL increase with temperature. Physical device simulations of different thin-film fully-depleted (FD) devices outline the generality of such behavior. SPICE simulations, with UTSOI DK2.4 model, only partially adhere to experimental trends. Several analytic models available in the literature are assessed for DIBL vs. temperature prediction. Although being the closest to experiments, Fasarakis' model overestimates DIBL(T) dependence for shortest devices and underestimates it for upsized gate lengths frequently used in ultra-low-voltage (ULV) applications. This model is improved in our work, by introducing a temperature-dependent inversion charge at threshold. The improved model shows very good agreement with experimental data, with high gain in precision for the gate lengths under test.

  11. Moderation of neoclassical impurity accumulation in high temperature plasmas of helical devices

    NASA Astrophysics Data System (ADS)

    Velasco, J. L.; Calvo, I.; Satake, S.; Alonso, A.; Nunami, M.; Yokoyama, M.; Sato, M.; Estrada, T.; Fontdecaba, J. M.; Liniers, M.; McCarthy, K. J.; Medina, F.; Van Milligen, B. Ph; Ochando, M.; Parra, F.; Sugama, H.; Zhezhera, A.; The LHD Experimental Team; The TJ-II Team

    2017-01-01

    Achieving impurity and helium ash control is a crucial issue in the path towards fusion-grade magnetic confinement devices, and this is particularly the case of helical reactors, whose low-collisionality ion-root operation scenarios usually display a negative radial electric field which is expected to cause inwards impurity pinch. In this work we discuss, based on experimental measurements and standard predictions of neoclassical theory, how plasmas of very low ion collisionality, similar to those observed in the impurity hole of the large helical device (Yoshinuma et al and The LHD Experimental Group 2009 Nucl. Fusion 49 062002, Ida et al and The LHD Experimental Group 2009 Phys. Plasmas 16 056111 and Yokoyama et al and LHD Experimental Group 2002 Nucl. Fusion 42 143), can be an exception to this general rule, and how a negative radial electric field can coexist with an outward impurity flux. This interpretation is supported by comparison with documented discharges available in the International Stellarator-Heliotron Profile Database, and it can be extrapolated to show that achievement of high ion temperature in the core of helical devices is not fundamentally incompatible with low core impurity content.

  12. A Survey of Keystroke Dynamics Biometrics

    PubMed Central

    Yue, Shigang

    2013-01-01

    Research on keystroke dynamics biometrics has been increasing, especially in the last decade. The main motivation behind this effort is due to the fact that keystroke dynamics biometrics is economical and can be easily integrated into the existing computer security systems with minimal alteration and user intervention. Numerous studies have been conducted in terms of data acquisition devices, feature representations, classification methods, experimental protocols, and evaluations. However, an up-to-date extensive survey and evaluation is not yet available. The objective of this paper is to provide an insightful survey and comparison on keystroke dynamics biometrics research performed throughout the last three decades, as well as offering suggestions and possible future research directions. PMID:24298216

  13. (Preoxidation cleaning optimization for crystalline silicon)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1991-01-01

    A series of controlled experiments has been performed in Sandia's Photovoltaic Device Fabrication Laboratory to evaluate the effect of various chemical surface treatments on the recombination lifetime of crystalline silicon wafers subjected to a high-temperature dry oxidation. From this series of experiments we have deduced a relatively simple yet effective cleaning sequence. We have also evaluated the effect of different chemical damage-removal etches for improving the recombination lifetime and surface smoothness of mechanically lapped wafers. This paper presents the methodology used, the experimental results obtained, and our experience with using this process on a continuing basis over a period ofmore » many months. 7 refs., 4 figs., 1 tab.« less

  14. Recent trends in the development and evaluation of assistive robotic manipulation devices.

    PubMed

    Allin, Sonya; Eckel, Emily; Markham, Heather; Brewer, Bambi R

    2010-02-01

    This review explores recent trends in the development and evaluation of assistive robotic arms, both prosthetic and externally mounted. Evaluations have been organized according to the CATOR taxonomy of assistive device outcomes, which takes into consideration device effectiveness, social significance, and impact on subjective well-being. Questions that have informed the review include: (1) Are robotic arms being comprehensively evaluated along axes of the CATOR taxonomy? (2) Are definitions of effectiveness in accordance with the priorities of users? (3) What gaps in robotic arm evaluation exist, and how might these best be addressed? (4) What further advances can be expected in the next 15 years? Results highlight the need for increased standardization of evaluation methods, increased emphasis on the social significance (i.e., social cost) of devices, and increased emphasis on device impact on quality of life. Several open areas for future research, in terms of both device evaluation and device development, are also discussed.

  15. pH-Responsive Hydrogel With an Anti-Glycation Agent for Modulating Experimental Periodontitis.

    PubMed

    Yu, Min-Chen; Chang, Chih-Yeun; Chao, Yi-Chi; Jheng, Yi-Han; Yang, Connie; Lee, Ning; Yu, Shan-Huey; Yu, Xin-Hong; Liu, Dean-Mo; Chang, Po-Chun

    2016-06-01

    Stimulus-responsive devices have emerged as a novel approach for local drug delivery. This study investigates the feasibility of a novel chitosan-based, pH-responsive hydrogel loaded with N-phenacylthiazolium bromide (PTB), which cleaves the crosslinks of advanced glycation end products on the extracellular matrix. A chitosan-based hydrogel loaded with PTB was fabricated, and the in vitro release profile was evaluated within pH 5.5 to 7.4. BALB/cJ mice and Sprague-Dawley rats were used to evaluate the effects during the induction and recovery phases of periodontitis, respectively, and animals in each phase were divided into four groups: 1) no periodontitis induction; 2) ligature-induced experimental periodontitis (group PR); 3) experimental periodontitis plus hydrogel without PTB (group PH); and 4) experimental periodontitis plus hydrogel with PTB (group PP). The therapeutic effects were evaluated by microcomputed tomographic imaging of periodontal bone level (PBL) loss and histomorphometry for inflammatory cell infiltration and collagen density. PTB was released faster at pH 5.5 to 6.5 and consistently slower at pH 7.4. In the induction phase, PBL and inflammatory cell infiltration were significantly reduced in group PP relative to group PR, and the loss of collagen matrix was significantly reduced relative to that observed in group PH. In the recovery phase, PBL and inflammatory cell infiltration were significantly reduced, and significantly greater collagen deposition was noted in group PP relative to groups PR and PH at 4 and 14 days after silk removal. Chitosan-based, pH-responsive hydrogels loaded with PTB can retard the initiation of and facilitate the recovery from experimental periodontitis.

  16. Liquid volume measurement method for the picoliter to nanoliter volume range based on quartz crystal microbalance technology

    NASA Astrophysics Data System (ADS)

    Liang, Dong; Zhang, Jin; Thanikhatla Govindaiah, Muniyogeshbabu; Tanguy, Laurent; Ernst, Andreas; Zengerle, Roland; Koltay, Peter

    2014-09-01

    In this article, a quantitative liquid volume measurement method for the sub-nanoliter range using a quartz crystal microbalance (QCM) is described and experimentally analyzed. The primary measurement device to determine the volume of small liquid droplets is a QCM sensor coated with a surface-attached hydrogel to improve the mechanical coupling of the liquid to the sensor surface. An experimental evaluation of measured volumes in the range of 3 nl to 15 nl in normal room conditions has been performed with three identical sensors prepared with a PDMAA-1%MaBP hydrogel coating with a thickness of 1.5 µm ± 0.12 µm. A linearity of R2 more than 0.87, an average coefficient of variation (CV) within one experimental run of 5.7%, a mean absolute relative bias of 5.5%, and a sensor-to-sensor variation of 6.3% have been experimentally determined. The feasibility of this method has also been experimentally proven for the picoliter volume range down to 200 pl, with an average CV of 5.3% and a mean absolute relative bias of 6.5%. Furthermore, a stability evaluation consisting of 10 experimental series with approximately 150 measurements over the course of one week has been performed. This evaluation showed that the experimental setup, although exhibiting highly consistent performance within one measurement run, is not yet reproducible enough for long-term and repeated use because of undefined swelling and crack formation in the hydrogel layer. The low reproducibility implies a relatively high expanded uncertainty, with k = 2 according to the JCGM ‘Evaluation of Measurement Data—Guide to the Expression of Uncertainty in Measurement’ (GUM) for the total measurement method of approximately 3.82 nl when measuring a 10 nl liquid droplet. Nevertheless, the QCM method as described here contributes to significant progress beyond the state-of-the-art that might allow new opportunities for precise measurement of sub-nanoliter liquid volumes.

  17. Evaluating Attenuation of Vibration Response using Particle Impact Damping for a Range of Equipment Assemblies

    NASA Technical Reports Server (NTRS)

    Knight, Brent; Parsons, David; Smith, Andrew; Hunt, Ron; LaVerde, Bruce; Towner, Robert; Craigmyle, Ben

    2013-01-01

    Particle dampers provide a mechanism for diverting energy away from resonant structural vibrations. This experimental study provides data from a series of acoustically excited tests to determine the effectiveness of these dampers for equipment mounted to a curved orthogrid panel for a launch vehicle application. Vibration attenuation trends are examined for variations in particle damper fill level, component mass, and excitation energy. A significant response reduction at the component level was achieved, suggesting that comparatively small, strategically placed, particle damper devices might be advantageously used in launch vehicle design. These test results were compared to baseline acoustic response tests without particle damping devices, over a range of isolation and damping parameters. Instrumentation consisting of accelerometers, microphones, and still photography data will be collected to correlate with the analytical results.

  18. Investigation of multilayer magnetic domain lattice file

    NASA Technical Reports Server (NTRS)

    Torok, E. J.; Kamin, M.; Tolman, C. H.

    1980-01-01

    The feasibility of the self structured multilayered bubble domain memory as a mass memory medium for satellite applications is examined. Theoretical considerations of multilayer bubble supporting materials are presented, in addition to the experimental evaluation of current accessed circuitry for various memory functions. The design, fabrication, and test of four device designs is described, and a recommended memory storage area configuration is presented. Memory functions which were demonstrated include the current accessed propagation of bubble domains and stripe domains, pinning of stripe domain ends, generation of single and double bubbles, generation of arrays of coexisting strip and bubble domains in a single garnet layer, and demonstration of different values of the strip out field for single and double bubbles indicating adequate margins for data detection. All functions necessary to develop a multilayer self structured bubble memory device were demonstrated in individual experiments.

  19. The economic evaluation of medical devices: challenges.

    PubMed

    Kingkaew, Pritaporn; Teerawattananon, Yot

    2014-05-01

    While many of the principles that guide the economic evaluation of medical devices are somewhat similar to those that guide the evaluation of other health technologies, most outline a methodology that focuses on pharmaceutical products rather providing specific guidance for medical devices. Given that medical devices use a wide range of technologies and can be used for many purposes, conducting an economic analysis for medical devices is not straightforward. The cost and effectiveness of a given technology may depend on a number of factors. The objective of this paper is to provide a summary of issues that need to be addressed before undertaking an economic evaluation of medical devices and to outline a number of suggested approaches for undertaking an economic evaluation of medical devices.

  20. Experimental and computational investigation of graphene/SAMs/n-Si Schottky diodes

    NASA Astrophysics Data System (ADS)

    Aydin, H.; Bacaksiz, C.; Yagmurcukardes, N.; Karakaya, C.; Mermer, O.; Can, M.; Senger, R. T.; Sahin, H.; Selamet, Y.

    2018-01-01

    We have investigated the effect of two different self-assembled monolayers (SAMs) on electrical characteristics of bilayer graphene (BLG)/n-Si Schottky diodes. Novel 4″bis(diphenylamino)-1, 1‧:3″-terphenyl-5‧ carboxylic acids (TPA) and 4,4-di-9H-carbazol-9-yl-1,1‧:3‧1‧-terphenyl-5‧ carboxylic acid (CAR) aromatic SAMs have been used to modify n-Si surfaces. Cyclic voltammetry (CV) and Kelvin probe force microscopy (KPFM) results have been evaluated to verify the modification of n-Si surface. The current-voltage (I-V) characteristics of bare and SAMs modified devices show rectification behaviour verifying a Schottky junction at the interface. The ideality factors (n) from ln(I)-V dependences were determined as 2.13, 1.96 and 2.07 for BLG/n-Si, BLG/TPA/n-Si and BLG/CAR/n-Si Schottky diodes, respectively. In addition, Schottky barrier height (SBH) and series resistance (Rs) of SAMs modified diodes were decreased compared to bare diode due to the formation of a compatible interface between graphene and Si as well as π-π interaction between aromatic SAMs and graphene. The CAR-based device exhibits better diode characteristic compared to the TPA-based device. Computational simulations show that the BLG/CAR system exhibits smaller energy-level-differences than the BLG/TPA, which supports the experimental findings of a lower Schottky barrier and series resistance in BLG/CAR diode.

  1. A Novel Passive Tracking Scheme Exploiting Geometric and Intercept Theorems

    PubMed Central

    Zhou, Biao; Sun, Chao; Ahn, Deockhyeon; Kim, Youngok

    2018-01-01

    Passive tracking aims to track targets without assistant devices, that is, device-free targets. Passive tracking based on Radio Frequency (RF) Tomography in wireless sensor networks has recently been addressed as an emerging field. The passive tracking scheme using geometric theorems (GTs) is one of the most popular RF Tomography schemes, because the GT-based method can effectively mitigate the demand for a high density of wireless nodes. In the GT-based tracking scheme, the tracking scenario is considered as a two-dimensional geometric topology and then geometric theorems are applied to estimate crossing points (CPs) of the device-free target on line-of-sight links (LOSLs), which reveal the target’s trajectory information in a discrete form. In this paper, we review existing GT-based tracking schemes, and then propose a novel passive tracking scheme by exploiting the Intercept Theorem (IT). To create an IT-based CP estimation scheme available in the noisy non-parallel LOSL situation, we develop the equal-ratio traverse (ERT) method. Finally, we analyze properties of three GT-based tracking algorithms and the performance of these schemes is evaluated experimentally under various trajectories, node densities, and noisy topologies. Analysis of experimental results shows that tracking schemes exploiting geometric theorems can achieve remarkable positioning accuracy even under rather a low density of wireless nodes. Moreover, the proposed IT scheme can provide generally finer tracking accuracy under even lower node density and noisier topologies, in comparison to other schemes. PMID:29562621

  2. Possible applications of the LEAP motion controller for more interactive simulated experiments in augmented or virtual reality

    NASA Astrophysics Data System (ADS)

    Wozniak, Peter; Vauderwange, Oliver; Mandal, Avikarsha; Javahiraly, Nicolas; Curticapean, Dan

    2016-09-01

    Practical exercises are a crucial part of many curricula. Even simple exercises can improve the understanding of the underlying subject. Most experimental setups require special hardware. To carry out e. g. a lens experiments the students need access to an optical bench, various lenses, light sources, apertures and a screen. In our previous publication we demonstrated the use of augmented reality visualization techniques in order to let the students prepare with a simulated experimental setup. Within the context of our intended blended learning concept we want to utilize augmented or virtual reality techniques for stationary laboratory exercises. Unlike applications running on mobile devices, stationary setups can be extended more easily with additional interfaces and thus allow for more complex interactions and simulations in virtual reality (VR) and augmented reality (AR). The most significant difference is the possibility to allow interactions beyond touching a screen. The LEAP Motion controller is a small inexpensive device that allows for the tracking of the user's hands and fingers in three dimensions. It is conceivable to allow the user to interact with the simulation's virtual elements by the user's very hand position, movement and gesture. In this paper we evaluate possible applications of the LEAP Motion controller for simulated experiments in augmented and virtual reality. We pay particular attention to the devices strengths and weaknesses and want to point out useful and less useful application scenarios.

  3. Non- contacting capacitive diagnostic device

    DOEpatents

    Ellison, Timothy

    2005-07-12

    A non-contacting capacitive diagnostic device includes a pulsed light source for producing an electric field in a semiconductor or photovoltaic device or material to be evaluated and a circuit responsive to the electric field. The circuit is not in physical contact with the device or material being evaluated and produces an electrical signal characteristic of the electric field produced in the device or material. The diagnostic device permits quality control and evaluation of semiconductor or photovoltaic device properties in continuous manufacturing processes.

  4. Theoretical Study of Gilbert Damping and Spin Dynamics in Spintronic Devices

    NASA Astrophysics Data System (ADS)

    Qu, Tao

    The determination of damping mechanisms is one of the most fundamental problems of magnetism. It represents the elimination of the magnetic energy and thus has broad impact in both science and technology. The dynamic time scale in spintronic devices is controlled by the damping and the consumed power depends on the damping constant squared. In recent years, the interest in high perpendicular anisotropy materials and thin film structures have increased considerably, owing to their stability over a wide temperature range when scaling devices to nanometer length scales. However, the conventional measurement method-Ferromagnetic resonance (FMR) can not produce accurate damping results in the high magnetic crystalline anisotropy materials/structures, and the intrinsic damping reported experimentally diverges among investigators, probably due to the varying fabrication techniques. This thesis describes the application of the Kambersky torque correlation technique, within the tight binding method, to multiple materials with high perpendicular magnetic anisotropy ( 10 7 erg/cm3), in both bulk and thin film structures. The impact of the inevitable experimental defects on the energy dissipation is identified and the experimental damping divergence among investigators due to the material degree of order is explained. It is demonstrated that this corresponds to an enhanced DOS at the Fermi level, owing to the rounding of the DOS with loss of long-range order. The consistency of the predicted damping constant with experimental measurement is demonstrated and the interface contribution to the energy damping constant in potential superlattices and heterostructures for spintronic devices is explored. An optimized structure will be a tradeoff involving both anisotropy and damping. The damping related spin dynamics in spintronic devices for different applications is investigated. One device is current perpendicular to planes(CPP) spin valve. Incoherent scattering matrices are applied to calculate the angle dependent magnetoresistantce and obtain analytic expressions for the spin valve. The non-linearity of magnetoresistance can be quantitatively explained by reflected electrons using only experimental spin polarization as input. The other device is a spin-transfer-torque nano-oscillator. The Landau-Lifshitz-Gilbert equation is applied and the synchronization requirement for experimentally fabricated non-identical multi spintronic oscillators is explored. Power enhancement and noise decrease for the synchronized state is demonstrated in a temperature range. Through introducing combined electric and magnetic coupling effect, a design for an optimized feasible nanopillar structure suitable for thin-film deposition is developed.

  5. 10 CFR 32.61 - Ice detection devices containing strontium-90; requirements for license to manufacture or...

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... physical form and maximum quantity of strontium-90 in the device; (2) Details of construction and design of... handling and installation of the device; (8) Any additional information, including experimental studies and... ordinary circumstances of use; (3) The device is so designed that it cannot be easily disassembled; (4) The...

  6. Feasibility and Limitations of Vaccine Two-Dimensional Barcoding Using Mobile Devices.

    PubMed

    Bell, Cameron; Guerinet, Julien; Atkinson, Katherine M; Wilson, Kumanan

    2016-06-23

    Two-dimensional (2D) barcoding has the potential to enhance documentation of vaccine encounters at the point of care. However, this is currently limited to environments equipped with dedicated barcode scanners and compatible record systems. Mobile devices may present a cost-effective alternative to leverage 2D vaccine vial barcodes and improve vaccine product-specific information residing in digital health records. Mobile devices have the potential to capture product-specific information from 2D vaccine vial barcodes. We sought to examine the feasibility, performance, and potential limitations of scanning 2D barcodes on vaccine vials using 4 different mobile phones. A unique barcode scanning app was developed for Android and iOS operating systems. The impact of 4 variables on the scan success rate, data accuracy, and time to scan were examined: barcode size, curvature, fading, and ambient lighting conditions. Two experimenters performed 4 trials 10 times each, amounting to a total of 2160 barcode scan attempts. Of the 1832 successful scans performed in this evaluation, zero produced incorrect data. Five-millimeter barcodes were the slowest to scan, although only by 0.5 seconds on average. Barcodes with up to 50% fading had a 100% success rate, but success rate deteriorated beyond 60% fading. Curved barcodes took longer to scan compared with flat, but success rate deterioration was only observed at a vial diameter of 10 mm. Light conditions did not affect success rate or scan time between 500 lux and 20 lux. Conditions below 20 lux impeded the device's ability to scan successfully. Variability in scan time was observed across devices in all trials performed. 2D vaccine barcoding is possible using mobile devices and is successful under the majority of conditions examined. Manufacturers utilizing 2D barcodes should take into consideration the impact of factors that limit scan success rates. Future studies should evaluate the effect of mobile barcoding on workflow and vaccine administrator acceptance.

  7. Performance of ultraviolet photocatalytic oxidation for indoor air cleaning applications.

    PubMed

    Hodgson, A T; Destaillats, H; Sullivan, D P; Fisk, W J

    2007-08-01

    Ultraviolet photocatalytic oxidation (UVPCO) systems for removal of volatile organic compounds (VOCs) from air are being considered for use in office buildings. Here, we report an experimental evaluation of a UVPCO device with tungsten oxide modified titanium dioxide (TiO2) as the photocatalyst. The device was challenged with complex VOC mixtures. One mixture contained 27 VOCs characteristic of office buildings and another comprised 10 VOCs emitted by cleaning products, in both cases at realistic concentrations (low ppb range). VOC conversion efficiencies varied widely, usually exceeded 20%, and were as high as approximately 80% at about 0.03 s residence time. Conversion efficiency generally diminished with increased airflow rate, and followed the order: alcohols and glycol ethers > aldehydes, ketones, and terpene hydrocarbons > aromatic and alkane hydrocarbons > halogenated aliphatic hydrocarbons. Conversion efficiencies correlated with the Henry's law constant more closely than with other physicochemical parameters. An empirical model based on the Henry's law constant and the gas-phase reaction rate with hydroxyl radical provided reasonable estimates of pseudo-first order photocatalytic reaction rates. Formaldehyde, acetaldehyde, acetone, formic acid and acetic acid were produced by the device due to incomplete mineralization of common VOCs. Formaldehyde outlet/inlet concentration ratios were in the range 1.9-7.2. Implementation of air cleaning technologies for both VOCs and particles in office buildings may improve indoor air quality, or enable indoor air quality levels to be maintained with reduced outdoor air supply and concomitant energy savings. One promising air cleaning technology is ultraviolet photocatalytic oxidation (UVPCO) air cleaning. For the prototype device evaluated here with realistic mixtures of VOCs, conversion efficiencies typically exceeded the minimum required to counteract predicted VOC concentration increases from a 50% reduction in ventilation. However, the device resulted in the net generation of formaldehyde and acetaldehyde from the partial oxidation of ubiquitous VOCs. Further development of the technology is needed to eliminate these hazardous air pollutants before such a UVPCO device can be deployed in buildings.

  8. Investigations of Baikal Lake water absorption with ASP-15 device: measurement method and experimental data

    NASA Astrophysics Data System (ADS)

    Kokhanenko, Grigorii P.; Tarashchansky, Boris A.; Budnev, Nikolai M.; Mirgazov, Rashid R.

    2006-02-01

    Operation of the device ASP-15 is analyzed in the paper. The device is arranged in the south part of Lake Baikal, and it is capable of all-the-year-round measurements of hydro-optical characteristics at the depths down to 1300 m. The method for determining the absorption coefficient is based on measurement of the rate of decrease of the irradiance from an isotropic source with the distance between the source and the receiver. Possible reasons of appearance of anomalous dependences of the irradiance with the distance are revealed on the basis of numerical simulation, and the errors of the applied method are estimated. The experimental data obtained by means of the device ASP-15 last years are presented.

  9. Terahertz-induced photothermoelectric response in graphene-metal contact structures

    NASA Astrophysics Data System (ADS)

    Deng, Xiangquan; Wang, Yingxin; Zhao, Ziran; Chen, Zhiqiang; Sun, Jia-Lin

    2016-10-01

    We report on the photoresponse of a graphene-metal contact device under terahertz (THz) illumination. The device has an extremely simple structure consisting of a large-area monolayer graphene stripe contacted with two gold electrodes. A significant position-dependent photovoltage is observed across the device by THz excitation, exhibiting a linear relationship with the incident beam power. Experimental results show that the graphene channel length and the substrate thermal conductivity have obvious influence on the photovoltage amplitude and response time, which is consistent with the photothermoelectric mechanism. This compact and powerless device is expected to have a promising application in THz detection. Our work provides theoretical and experimental evidence for the development of high-performance graphene-based THz photodetectors.

  10. On metal contacts of terahertz quantum cascade lasers with a metal-metal waveguide

    NASA Astrophysics Data System (ADS)

    Fathololoumi, Saeed; Dupont, Emmanuel; Ghasem Razavipour, S.; Laframboise, Sylvain R.; Parent, Guy; Wasilewski, Zbigniew; Liu, H. C.; Ban, Dayan

    2011-10-01

    This paper reports an experimental study of the effects of different metal claddings on the performance of terahertz quantum cascade lasers. The experimental results show that by using a metal cladding made of Ta/Cu/Au to replace that of Pd/Ge/Ti/Pt/Au, the maximum lasing temperature of the devices is increased from 132 to 172 K, and the threshold current density of the devices at 10 K can be reduced from 0.74 to 0.68 kA cm-2. The improvement of the device performance is attributed to lower optical losses associated with the metal cladding layers. The different effects of the metal contacts on device optical properties and electrical properties are also discussed.

  11. Finite-element analysis of NiTi wire deflection during orthodontic levelling treatment

    NASA Astrophysics Data System (ADS)

    Razali, M. F.; Mahmud, A. S.; Mokhtar, N.; Abdullah, J.

    2016-02-01

    Finite-element analysis is an important product development tool in medical devices industry for design and failure analysis of devices. This tool helps device designers to quickly explore various design options, optimizing specific designs and providing a deeper insight how a device is actually performing. In this study, three-dimensional finite-element models of superelastic nickel-titanium arch wire engaged in a three brackets system were developed. The aim was to measure the effect of binding friction developed on wire-bracket interaction towards the remaining recovery force available for tooth movement. Uniaxial and three brackets bending test were modelled and validated against experimental works. The prediction made by the three brackets bending models shows good agreement with the experimental results.

  12. Evaluation of phenyl-propanedione on yellowing and chemical-mechanical properties of experimental dental resin-based materials.

    PubMed

    Oliveira, Dayane Carvalho Ramos Salles de; Souza-Junior, Eduardo José; Dobson, Adam; Correr, Ana Rosa Costa; Brandt, William Cunha; Sinhoreti, Mário Alexandre Coelho

    2016-01-01

    To evaluate the influence of phenyl-propanedione on yellowing and chemical-mechanical properties of experimental resin-based materials photoactivated using different light curing units (LCUs). Experimental resin-based materials with the same organic matrix (60:40 wt% BisGMA:TEGDMA) were mechanically blended using a centrifugal mixing device. To this blend, different photoinitiator systems were added in equimolar concentrations with aliphatic amine doubled by wt%: 0.4 wt% CQ; 0.38 wt% PPD; or 0.2 wt% CQ and 0.19 wt% PPD. The degree of conversion (DC), flexural strength (FS), Young's modulus (YM), Knoop hardness (KNH), crosslinking density (CLD), and yellowing (Y) were evaluated (n=10). All samples were light cured with the following LCUs: a halogen lamp (XL 2500), a monowave LED (Radii), or a polywave LED (Valo) with 16 J/cm2. The results were analysed by two-way ANOVA and Tukey's test (α=0.05). No statistical differences were found between the different photoinitiator systems to KNH, CLS, FS, and YM properties (p≥0.05). PPD/CQ association showed the higher DC values compared with CQ and PPD isolated systems when photoactivated by a polywave LED (p≤0.05). Y values were highest for the CQ compared with the PPD systems (p≤0.05). PPD isolated system promoted similar chemical and mechanical properties and less yellowing compared with the CQ isolated system, regardless of the LCU used.

  13. Evaluating effectiveness of dynamic soundfield system in the classroom.

    PubMed

    da Cruz, Aline Duarte; Alves Silvério, Kelly Cristina; Da Costa, Aline Roberta Aceituno; Moret, Adriane Lima Mortari; Lauris, José Roberto Pereira; de Souza Jacob, Regina Tangerino

    2016-01-01

    Research has reported on the use of soundfield amplification devices in the classroom. However, no study has used standardized tests to determine the potential advantages of the dynamic soundfield system for normally hearing students and for the teacher's voice. Our aim was to evaluate the impact of using dynamic soundfield system on the noise of the classroom, teacher's voice and students' academic performance. This was a prospective cohort study in which 20 student participants enrolled in the third year of basic education were divided into two groups (i.e., control and experimental); their teacher participated. The experimental group was exposed to the dynamic soundfield system for 3 consecutive months. The groups were assessed using standardized tests to evaluate their academic performance. Further, questionnaires and statements were collected on the participants' experience of using the soundfield system. We statistically analyzed the results to compare the academic performance of the control group with that of the experimental group. In all cases, a significance level of P < .05 was adopted. Use of the dynamic soundfield system was effective for improving the students' academic performance on standardized tests for reading, improving the teacher's speech intelligibility, and reducing the teacher's vocal strain. The dynamic soundfield system minimizes the impact of noise in the classroom as demonstrated by the mensuration of the signal-to-noise ratio (SNR) and pupil performance on standardized tests for reading and student and teacher ratings of amplification system effectiveness.

  14. Evaluation of Thermoelectric Devices by the Slope-Efficiency Method

    DTIC Science & Technology

    2016-09-01

    ARL-TR-7837 ● SEP 2016 US Army Research Laboratory Evaluation of Thermoelectric Devices by the Slope-Efficiency Method by...Evaluation of Thermoelectric Devices by the Slope-Efficiency Method by Patrick J Taylor Sensors and Electron Devices Directorate, ARL Jay R...

  15. An Initial Evaluation of Tablet Devices & What Are the Next Steps?

    ERIC Educational Resources Information Center

    McKillen, Tracey

    2016-01-01

    This paper describes an evaluation of tablet devices for a Graduate Entry Medical School (GEMS). The purpose of this evaluation is to assess what type of tablet device could meet the needs of a GEMS student. GEMS requirements for the evaluation include; using the tablet device to replace paper teaching resources in lectures and tutorials and…

  16. Development for equipment of the milk macromolecules content detection

    NASA Astrophysics Data System (ADS)

    Ding, Guochao; Li, Weimin; Shang, Tingyi; Xi, Yang; Gao, Yunli; Zhou, Zhen

    Developed an experimental device for rapid and accurate detection of milk macromolecular content. This device developed based on laser scattered through principle, the principle use of the ingredients of the scattered light and transmitted light ratio characterization of macromolecules. Peristaltic pump to achieve automatic input and output of the milk samples, designing weak signal detection amplifier circuit for detecting the ratio with ICL7650. Real-time operating system μC / OS-II is the core design of the software part of the whole system. The experimental data prove that the device can achieve a fast real-time measurement of milk macromolecules.

  17. 3D Printed Composites for Topology Transforming Multifunctional Devices

    DTIC Science & Technology

    2017-01-26

    approach to find non -trivial designs. The comparison against experimental measurements motivates future research on improving the accuracy of the...new methodology for the fabrication and the design of new multifunctional composites and devices using 3D printing. The main accomplishments of this...design; 6) developing a finite element framework for the optimum design of PACS by topology optimization; 7) optimizing and experimentally

  18. Efficacy of new low-cost filtration device for recovering Schistosoma haematobium eggs from urine.

    PubMed

    Gyorkos, T W; Ramsan, M; Foum, A; Khamis, I S

    2001-07-01

    A new, inexpensive filtration device for the diagnosis of urinary schistosomiasis was tested against the commonly used Millipore device. The experimental protocol was performed with 25 urine samples known to be positive for Schistosoma haematobium. The results suggest that the new device is as effective as the Millipore device for the diagnosis of urinary schistosomiasis. Its low cost will be attractive to schistosomiasis control programs.

  19. A Systematic Review of Commercial Cognitive Training Devices: Implications for Use in Sport

    PubMed Central

    Harris, David J.; Wilson, Mark R.; Vine, Samuel J.

    2018-01-01

    Background: Cognitive training (CT) aims to develop a range of skills, like attention and decision-making, through targeted training of core cognitive functions. While CT can target context specific skills, like movement anticipation, much CT is domain general, focusing on core abilities (e.g., selective attention) for transfer to a range of real-world tasks, such as spotting opponents. Commercial CT (CCT) devices are highly appealing for athletes and coaches due to their ease of use and eye-catching marketing claims. The extent to which this training transfers to performance in the sporting arena is, however, unclear. Therefore, this paper sought to provide a systematic review of evidence for beneficial training effects of CCT devices and evaluate their application to sport. Methods: An extensive search of electronic databases (PubMed, PsychInfo, GoogleScholar, and SportDiscus) was conducted to identify peer-reviewed evidence of training interventions with commercially available CT devices. Forty-three studies met the inclusion criteria and were retained for quality assessment and synthesis of results. Seventeen studies assessed transfer effects beyond laboratory cognitive tests, but only 1 directly assessed transfer to a sporting task. Results: The review of evidence showed limited support for far transfer benefits from CCT devices to sporting tasks, mainly because studies did not target the sporting environment. Additionally, a number of methodological issues with the CCT literature were identified, including small sample sizes, lack of retention tests, and limited replication of findings by researchers independent of the commercial product. Therefore, evidence for sporting benefits is currently limited by the paucity of representative transfer tests and a focus on populations with health conditions. Conclusions: Currently there is little direct evidence that the use of CCT devices can transfer to benefits for sporting performance. This conclusion, however, stems more from a lack of experimental studies in the sporting field and a lack of experimental rigor, rather than convincing null effects. Subsequently, there is an opportunity for researchers to develop more reliable findings in this area through systematic assessment in athletic populations and major methodological improvements.

  20. Design and fabrication of an energy-harvesting device using vibration absorber

    NASA Astrophysics Data System (ADS)

    Heidari, Hamidreza; Afifi, Arash

    2017-05-01

    Energy-harvesting devices collect energy that is being wasted and convert to the electrical energy. For this reason, this type of devices is considered as a convenient alternative to traditional batteries. In this paper, experimental examinations were performed to investigate the application of harvesting device for the reduction of the vibration amplitude in a vibration system and also increase the efficiency of energy-harvesting device. This study focuses on the energy-harvesting device as both producing electrical device and a vibration disabled absorber. In this regard, a motion-based energy-harvesting device is designed to produce electrical energy and also eliminate vibrations of a two joint-end beam which is located under the harmonic excitation force. Then, the governing equations of the forced motion on the main beam are derived and energy-harvesting system are simulated. In addition, the system designed by MATLAB simulation is explained and its results are expressed. Finally, a prototype of the system was made and the ability of the energy-harvesting device to absorb the original system vibrations, as well as parameters impact on the efficiency of energy harvesting is investigated. Experimental results show that the energy-harvesting device, in addition to producing electric current with a maximum value of 1.5V, reduces 94% of the original system vibrations.

  1. Development of a test rig for a helium twin-screw compressor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, B. M.; Hu, Z. J.; Zhang, P.

    2014-01-29

    A large helium cryogenic system is being developed for use in great science projects, such as the International Thermonuclear Experimental Reactor (ITER), Large Helical Device (LHD), and the Experimental Advanced Superconducting Tokamak (EAST). In this cryogenic system, a twin-screw compressor is a key component. Therefore, it is necessary to obtain the compressor performance. To obtain the performance characteristics, a test rig for the compressor has been built. All the important performance parameters, including adiabatic efficiency, volumetric efficiency, oil injection characteristic, and noise characteristic can be acquired with the rig when sensors are installed in the test system. With the testmore » performance, the helium twin-screw compressor can be evaluated. Using these results, the design of the compressor can be improved.« less

  2. Flow optimization study of a batch microfluidics PET tracer synthesizing device

    PubMed Central

    Elizarov, Arkadij M.; Meinhart, Carl; van Dam, R. Michael; Huang, Jiang; Daridon, Antoine; Heath, James R.; Kolb, Hartmuth C.

    2010-01-01

    We present numerical modeling and experimental studies of flow optimization inside a batch microfluidic micro-reactor used for synthesis of human-scale doses of Positron Emission Tomography (PET) tracers. Novel techniques are used for mixing within, and eluting liquid out of, the coin-shaped reaction chamber. Numerical solutions of the general incompressible Navier Stokes equations along with time-dependent elution scalar field equation for the three dimensional coin-shaped geometry were obtained and validated using fluorescence imaging analysis techniques. Utilizing the approach presented in this work, we were able to identify optimized geometrical and operational conditions for the micro-reactor in the absence of radioactive material commonly used in PET related tracer production platforms as well as evaluate the designed and fabricated micro-reactor using numerical and experimental validations. PMID:21072595

  3. Analysis and Experimental Investigation of Optimum Design of Thermoelectric Cooling/Heating System for Car Seat Climate Control (CSCC)

    NASA Astrophysics Data System (ADS)

    Elarusi, Abdulmunaem; Attar, Alaa; Lee, HoSung

    2018-02-01

    The optimum design of a thermoelectric system for application in car seat climate control has been modeled and its performance evaluated experimentally. The optimum design of the thermoelectric device combining two heat exchangers was obtained by using a newly developed optimization method based on the dimensional technique. Based on the analytical optimum design results, commercial thermoelectric cooler and heat sinks were selected to design and construct the climate control heat pump. This work focuses on testing the system performance in both cooling and heating modes to ensure accurate analytical modeling. Although the analytical performance was calculated using the simple ideal thermoelectric equations with effective thermoelectric material properties, it showed very good agreement with experiment for most operating conditions.

  4. 47 CFR 74.870 - Wireless video assist devices.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... wireless video assist devices may not be transferred or assigned. (i) The product literature that... 47 Telecommunication 4 2010-10-01 2010-10-01 false Wireless video assist devices. 74.870 Section... EXPERIMENTAL RADIO, AUXILIARY, SPECIAL BROADCAST AND OTHER PROGRAM DISTRIBUTIONAL SERVICES Low Power Auxiliary...

  5. A wireless potentiostat for mobile chemical sensing and biosensing.

    PubMed

    Steinberg, Matthew D; Kassal, Petar; Kereković, Irena; Steinberg, Ivana Murković

    2015-10-01

    Wireless chemical sensors are used as analytical devices in homeland defence, home-based healthcare, food logistics and more generally for the Sensor Internet of Things (SIoT). Presented here is a battery-powered and highly portable credit-card size potentiostat that is suitable for performing mobile and wearable amperometric electrochemical measurements with seamless wireless data transfer to mobile computing devices. The mobile electrochemical analytical system has been evaluated in the laboratory with a model redox system - the reduction of hexacyanoferrate(III) - and also with commercially available enzymatic blood-glucose test-strips. The potentiostat communicates wirelessly with mobile devices such as tablets or Smartphones by near-field communication (NFC) or with personal computers by radio-frequency identification (RFID), and thus provides a solution to the 'missing link' in connectivity that often exists between low-cost mobile and wearable chemical sensors and ubiquitous mobile computing products. The mobile potentiostat has been evaluated in the laboratory with a set of proof-of-concept experiments, and its analytical performance compared with a commercial laboratory potentiostat (R(2)=0.9999). These first experimental results demonstrate the functionality of the wireless potentiostat and suggest that the device could be suitable for wearable and point-of-sample analytical measurements. We conclude that the wireless potentiostat could contribute significantly to the advancement of mobile chemical sensor research and adoption, in particular for wearable sensors in healthcare and sport physiology, for wound monitoring and in mobile point-of-sample diagnostics as well as more generally as a part of the Sensor Internet of Things. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Experimental investigation of vapor shielding effects induced by ELM-like pulsed plasma loads using the double plasma gun device

    NASA Astrophysics Data System (ADS)

    Sakuma, I.; Kikuchi, Y.; Kitagawa, Y.; Asai, Y.; Onishi, K.; Fukumoto, N.; Nagata, M.

    2015-08-01

    We have developed a unique experimental device of so-called double plasma gun, which consists of two magnetized coaxial plasma gun (MCPG) devices, in order to clarify effects of vapor shielding on material erosion due to transient events in magnetically confined fusion devices. Two ELM-like pulsed plasmas produced by the two MCPG devices were injected into a target chamber with a variable time difference. For generating ablated plasmas in front of a target material, an aluminum foil sample in the target chamber was exposed to a pulsed plasma produced by the 1st MCPG device. The 2nd pulsed plasma was produced with a time delay of 70 μs. It was found that a surface absorbed energy measured by a calorimeter was reduced to ∼66% of that without the Al foil sample. Thus, the reduction of the incoming plasma energy by the vapor shielding effect was successfully demonstrated in the present experiment.

  7. Micro- and nano-scale optical devices for high density photonic integrated circuits at near-infrared wavelengths

    NASA Astrophysics Data System (ADS)

    Chatterjee, Rohit

    In this research work, we explore fundamental silicon-based active and passive photonic devices that can be integrated together to form functional photonic integrated circuits. The devices which include power splitters, switches and lenses are studied starting from their physics, their design and fabrication techniques and finally from an experimental standpoint. The experimental results reveal high performance devices that are compatible with standard CMOS fabrication processes and can be easily integrated with other devices for near infrared telecom applications. In Chapter 2, a novel method for optical switching using nanomechanical proximity perturbation technique is described and demonstrated. The method which is experimentally demonstrated employs relatively low powers, small chip footprint and is compatible with standard CMOS fabrication processes. Further, in Chapter 3, this method is applied to develop a hitless bypass switch aimed at solving an important issue in current wavelength division multiplexing systems namely hitless switching of reconfigurable optical add drop multiplexers. Experimental results are presented to demonstrate the application of the nanomechanical proximity perturbation technique to practical situations. In Chapter 4, a fundamental photonic component namely the power splitter is described. Power splitters are important components for any photonic integrated circuits because they help split the power from a single light source to multiple devices on the same chip so that different operations can be performed simultaneously. The power splitters demonstrated in this chapter are based on multimode interference principles resulting in highly compact low loss and highly uniform power splitting to split the power of the light from a single channel to two and four channels. These devices can further be scaled to achieve higher order splitting such as 1x16 and 1x32 power splits. Finally in Chapter 5 we overcome challenges in device fabrication and measurement techniques to demonstrate for the first time a "superlens" for the technologically important near infrared wavelength ranges with the opportunity to scale down further to visible wavelengths. The observed resolution is 0.47lambda, clearly smaller than the diffraction limit of 0.61lambda and is supported by detailed theoretical analyses and comprehensive numerical simulations. Importantly, we clearly show for the first time this subdiffraction limit imaging is due to the resonant excitation of surface slab modes, permitting amplification of evanescent waves. The demonstrated "superlens" has the largest figure of merit ever reported till date both theoretically and experimentally. The techniques and devices described in this thesis can be further applied to develop new devices with different functionalities. In Chapter 6 we describe two examples using these ideas. First, we experimentally demonstrate the use of the nanomechanical proximity perturbation technique to develop a phase retarder for on-chip all state polarization control. Next, we use the negative refraction photonic crystals described in Chapter 5 to achieve a special kind of bandgap called the zero-n¯ bandgap having unique properties.

  8. MEDICAL DEVICE PRICES IN ECONOMIC EVALUATIONS.

    PubMed

    Akpinar, Ilke; Jacobs, Philip; Husereau, Don

    2015-01-01

    Economic evaluations, although not formally used in purchasing decisions for medical devices in Canada, are still being conducted and published. The aim of this study was to examine the way that prices have been included in Canadian economic evaluations of medical devices. We conducted a review of the economic concepts and implications of methods used for economic evaluations of the eleven most implanted medical devices from the Canadian perspective. We found Canadian economic studies for five of the eleven medical devices and identified nineteen Canadian studies. Overall, the device costs were important components of total procedure cost, with an average ratio of 44.1 %. Observational estimates of the device costs were obtained from buyers or sellers in 13 of the 19 studies. Although most of the devices last more than 1 year, standard costing methods for capital equipment was never used. In addition, only eight studies included a sensitivity analysis for the device cost. None of the sensitivity analyses were based on actual price distributions. Economic evaluations are potentially important for policy making, but although they are being conducted, there is no standardized approach for incorporating medical device prices in economic analyses. Our review provides suggestions for improvements in how the prices are incorporated for economic evaluations of medical devices.

  9. Security analysis on some experimental quantum key distribution systems with imperfect optical and electrical devices

    NASA Astrophysics Data System (ADS)

    Liang, Lin-Mei; Sun, Shi-Hai; Jiang, Mu-Sheng; Li, Chun-Yan

    2014-10-01

    In general, quantum key distribution (QKD) has been proved unconditionally secure for perfect devices due to quantum uncertainty principle, quantum noncloning theorem and quantum nondividing principle which means that a quantum cannot be divided further. However, the practical optical and electrical devices used in the system are imperfect, which can be exploited by the eavesdropper to partially or totally spy the secret key between the legitimate parties. In this article, we first briefly review the recent work on quantum hacking on some experimental QKD systems with respect to imperfect devices carried out internationally, then we will present our recent hacking works in details, including passive faraday mirror attack, partially random phase attack, wavelength-selected photon-number-splitting attack, frequency shift attack, and single-photon-detector attack. Those quantum attack reminds people to improve the security existed in practical QKD systems due to imperfect devices by simply adding countermeasure or adopting a totally different protocol such as measurement-device independent protocol to avoid quantum hacking on the imperfection of measurement devices [Lo, et al., Phys. Rev. Lett., 2012, 108: 130503].

  10. Geotaxis baseline data for Drosophila

    NASA Technical Reports Server (NTRS)

    Schnebel, E. M.; Bhargava, R.; Grossfield, J.

    1987-01-01

    Geotaxis profiles for 20 Drosophila species and semispecies at different ages have been examined using a calibrated, adjustable slant board device. Measurements were taken at 5 deg intervals ranging from 0 deg to 85 deg. Clear strain and species differences are observed, with some groups tending to move upward (- geotaxis) with increasing angles, while others move downward (+ geotaxis). Geotactic responses change with age in some, but not all experimental groups. Sample geotaxis profiles are presented and their application to ecological and aging studies are discussed. Data provide a baseline for future evaluations of the biological effects of microgravity.

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Yimeng; Zhang, Xinping, E-mail: Zhangxinping@bjut.edu.cn; Zhang, Jian

    We investigate stretching-induced microscopic deformations spatially distributed in a flexible plate of polydimethylsiloxane (PDMS) and their applications in the broadening of the output spectrum of a femtosecond optical parametric oscillator. The hologram of the stretched PDMS plate was used to evaluate indirectly the microscopic deformations. The experimental results show that these deformations exhibit weak scattering and diffraction of light and induce negligible cavity loss, ensuring practical applications of the PDMS plate as an intracavity device for lasers. In combination with the thickness reduction of the PDMS plate through stretching, the distributed deformations enable smooth tuning of the output spectrum.

  12. Numerical simulation of the coaxial magneto-plasma accelerator and non-axisymmetric radio frequency discharge

    NASA Astrophysics Data System (ADS)

    Kuzenov, V. V.; Ryzhkov, S. V.; Frolko, P. A.

    2017-05-01

    The paper presents the results of mathematical modeling of physical processes in electronic devices such as helicon discharge and coaxial pulsed plasma thruster. A mathematical model of coaxial magneto-plasma accelerator (with a preionization helicon discharge), which allows estimating the transformation of one form of energy to another, as well as to evaluate the level of the contribution of different types of energy, the increase in mass of the accelerated plasmoid in the process of changing the speed. Main plasma parameters with experimental data were compared.

  13. Large current MOSFET on photonic silicon-on-insulator wafers and its monolithic integration with a thermo-optic 2 × 2 Mach-Zehnder switch.

    PubMed

    Cong, G W; Matsukawa, T; Chiba, T; Tadokoro, H; Yanagihara, M; Ohno, M; Kawashima, H; Kuwatsuka, H; Igarashi, Y; Masahara, M; Ishikawa, H

    2013-03-25

    n-channel body-tied partially depleted metal-oxide-semiconductor field-effect transistors (MOSFETs) were fabricated for large current applications on a silicon-on-insulator wafer with photonics-oriented specifications. The MOSFET can drive an electrical current as large as 20 mA. We monolithically integrated this MOSFET with a 2 × 2 Mach-Zehnder interferometer optical switch having thermo-optic phase shifters. The static and dynamic performances of the integrated device are experimentally evaluated.

  14. [Clinical development of the automatic implantable defibrillator over 35 years: A success story].

    PubMed

    Steinbeck, G

    2015-06-01

    After 12 years of development and experimental evaluation, the first automatic implantable cardioverter-defibrillator (ICD) was implanted in man on February 4, 1980. This overview describes the technical and functional developments over 35 years from a simple shock-box, weighing 292 g, to the sophisticated 80 g device of today, delivering graded therapy to sustained ventricular arrhythmias and biventricular stimulation to treat heart failure. Finally, a special tribute is given to Michel Mirowski, one of the inventors of the ICD, as scientist and physician dedicated to patient care.

  15. Improved Capacitive Liquid Sensor

    NASA Technical Reports Server (NTRS)

    Waldman, Francis A.

    1992-01-01

    Improved capacitive sensor used to detect presence and/or measure thickness of layer of liquid. Electrical impedance or admittance of sensor measured at prescribed frequency, and thickness of liquid inferred from predetermined theoretical or experimental relationship between impedance and thickness. Sensor is basically a three-terminal device. Features interdigitated driving and sensing electrodes and peripheral coplanar ground electrode that reduces parasitic effects. Patent-pending because first to utilize ground plane as "shunting" electrode. System less expensive than infrared, microwave, or refractive-index systems. Sensor successfully evaluated in commercial production plants to characterize emulsions, slurries, and solutions.

  16. Finite element analysis of a percussion device for pulmonary diagnostics

    NASA Astrophysics Data System (ADS)

    Dhar, Aneesh

    A pneumothorax is a medical condition where one or both lungs are unable to remain expanded due to air in the pleural space. Finite Element Analysis simulations were conducted on a Percussion Device, which is able to diagnose a pneumothorax using an automated percussion technique. The simulations helped determine the natural modes of vibration of the Percussion Device. These modes were then compared to the motion experimentally measured by an accelerometer on the Percussion Device. It was observed that the modes of the percussion head occurred in the range of 0 to 100 Hz, while the sensor membrane modes occurred in the range of 600 to 900 Hz. Most of these modes were found to match with peaks in the experimental spectra. The simulations performed are reliable and provide an understanding of the contribution of the normal modes to the complex signals measured using the Percussion Device.

  17. Passive thermal management using phase change materials

    NASA Astrophysics Data System (ADS)

    Ganatra, Yash Yogesh

    The trend of enhanced functionality and reducing thickness of mobile devices has. led to a rapid increase in power density and a potential thermal bottleneck since. thermal limits of components remain unchanged. Active cooling mechanisms are not. feasible due to size, weight and cost constraints. This work explores the feasibility. of a passive cooling system based on Phase Change Materials (PCMs) for thermal. management of mobile devices. PCMs stabilize temperatures due to the latent heat. of phase change thus increasing the operating time of the device before threshold. temperatures are exceeded. The primary contribution of this work is the identification. of key parameters which influence the design of a PCM based thermal management. system from both the experiments and the numerical models. This work first identifies strategies for integrating PCMs in an electronic device. A. detailed review of past research, including experimental techniques and computational. models, yields key material properties and metrics to evaluate the performance of. PCMs. Subsequently, a miniaturized version of a conventional thermal conductivity. measurement technique is developed to characterize thermal resistance of PCMs. Further, latent heat and transition temperatures are also characterized for a wide. range of PCMs. In-situ measurements with PCMs placed on the processor indicate that some. PCMs can extend the operating time of the device by as much as a factor of 2.48. relative to baseline tests (with no PCMs). This increase in operating time is investigated. by computational thermal models that explore various integration locations, both at the package and device level.

  18. Terminal illness and access to Phase 1 experimental agents, surgeries and devices: reviewing the ethical arguments.

    PubMed

    Schüklenk, Udo; Lowry, Christopher

    2009-01-01

    The advent of AIDS brought about a group of patients unwilling to accept crucial aspects of the methodological standards for clinical research investigating Phase 1 drugs, surgeries or devices. Their arguments against placebo controls in trials, which depended--at the time--on the terminal status of patient volunteers led to a renewed discussion of the ethics of denying patients with catastrophic illnesses access to last-chance experimental drugs, surgeries or devices. Existing ethics and health policy literature on the topic of access to experimental drugs. The positions of those arguing for or against free access to experimental drugs for terminally ill patients are irreconcilable. At stake are questions about the kinds of personal sacrifices society can reasonably expect patients in clinical trials to make to ensure statistically predictive results. These would benefit by necessity a much larger number of current and future patients--the conflict is about individual versus public interests. It is also about the question of whether or not the state can legitimately prevent patients with terminal illnesses from unfettered access to experimental drugs, surgeries or devices in order to motivate them to participate in clinical trials. We review the ethical arguments for and against the provision of access to Phase 1 agents for terminally ill patients. Finding a compromise between providing free or no access to Phase 1 drugs for terminally ill patients. We ought to investigate means to increase access to experimental drugs for terminally ill patients without sacrificing necessary clinical trials' sounds scientific methods.

  19. On the Use of the Platelet Activity State Assay for the In Vitro Quantification of Platelet Activation in Blood Recirculating Devices for Extracorporeal Circulation.

    PubMed

    Consolo, Filippo; Valerio, Lorenzo; Brizzola, Stefano; Rota, Paolo; Marazzato, Giulia; Vincoli, Valentina; Reggiani, Stefano; Redaelli, Alberto; Fiore, Gianfranco

    2016-10-01

    We designed an experimental setup to characterize the thrombogenic potential associated with blood recirculating devices (BRDs) used in extracorporeal circulation (ECC). Our methodology relies on in vitro flow loop platelet recirculation experiments combined with the modified-prothrombinase platelet activity state (PAS) assay to quantify the bulk thrombin production rate of circulated platelets, which correlates to the platelet activation (PA) level. The method was applied to a commercial neonatal hollow fiber membrane oxygenator. In analogous hemodynamic environment, we compared the PA level resulting from multiple passes of platelets within devices provided with phosphorylcholine (PC)-coated and noncoated (NC) fibers to account for flow-related mechanical factors (i.e., fluid-induced shear stress) together with surface contact activation phenomena. We report for the first time that PAS assay is not significantly sensitive to the effect of material coating under clinically pertinent flow conditions (500 mL/min), while providing straightforward information on shear-mediated PA dynamics in ECC devices. Being that the latter is intimately dependent on local flow dynamics, according to our results, the rate of thrombin production as measured by the PAS assay is a valuable biochemical marker of the selective contribution of PA in BRDs induced by device design features. Thus, we recommend the use of PAS assay as a means of evaluating the effect of modification of specific device geometrical features and/or different design solutions for developing ECC devices providing flow conditions with reduced thrombogenic impact. Copyright © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  20. A "twisted" microfluidic mixer suitable for a wide range of flow rate applications.

    PubMed

    Sivashankar, Shilpa; Agambayev, Sumeyra; Mashraei, Yousof; Li, Er Qiang; Thoroddsen, Sigurdur T; Salama, Khaled Nabil

    2016-05-01

    This paper proposes a new "twisted" 3D microfluidic mixer fabricated by a laser writing/microfabrication technique. Effective and efficient mixing using the twisted micromixers can be obtained by combining two general chaotic mixing mechanisms: splitting/recombining and chaotic advection. The lamination of mixer units provides the splitting and recombination mechanism when the quadrant of circles is arranged in a two-layered serial arrangement of mixing units. The overall 3D path of the microchannel introduces the advection. An experimental investigation using chemical solutions revealed that these novel 3D passive microfluidic mixers were stable and could be operated at a wide range of flow rates. This micromixer finds application in the manipulation of tiny volumes of liquids that are crucial in diagnostics. The mixing performance was evaluated by dye visualization, and using a pH test that determined the chemical reaction of the solutions. A comparison of the tornado-mixer with this twisted micromixer was made to evaluate the efficiency of mixing. The efficiency of mixing was calculated within the channel by acquiring intensities using ImageJ software. Results suggested that efficient mixing can be obtained when more than 3 units were consecutively placed. The geometry of the device, which has a length of 30 mm, enables the device to be integrated with micro total analysis systems and other lab-on-chip devices.

  1. A “twisted” microfluidic mixer suitable for a wide range of flow rate applications

    PubMed Central

    Sivashankar, Shilpa; Agambayev, Sumeyra; Mashraei, Yousof; Li, Er Qiang; Thoroddsen, Sigurdur T.; Salama, Khaled Nabil

    2016-01-01

    This paper proposes a new “twisted” 3D microfluidic mixer fabricated by a laser writing/microfabrication technique. Effective and efficient mixing using the twisted micromixers can be obtained by combining two general chaotic mixing mechanisms: splitting/recombining and chaotic advection. The lamination of mixer units provides the splitting and recombination mechanism when the quadrant of circles is arranged in a two-layered serial arrangement of mixing units. The overall 3D path of the microchannel introduces the advection. An experimental investigation using chemical solutions revealed that these novel 3D passive microfluidic mixers were stable and could be operated at a wide range of flow rates. This micromixer finds application in the manipulation of tiny volumes of liquids that are crucial in diagnostics. The mixing performance was evaluated by dye visualization, and using a pH test that determined the chemical reaction of the solutions. A comparison of the tornado-mixer with this twisted micromixer was made to evaluate the efficiency of mixing. The efficiency of mixing was calculated within the channel by acquiring intensities using ImageJ software. Results suggested that efficient mixing can be obtained when more than 3 units were consecutively placed. The geometry of the device, which has a length of 30 mm, enables the device to be integrated with micro total analysis systems and other lab-on-chip devices. PMID:27453767

  2. Flexible electronics-compatible non-enzymatic glucose sensing via transparent CuO nanowire networks on PET films

    NASA Astrophysics Data System (ADS)

    Bell, Caroline; Nammari, Abdullah; Uttamchandani, Pranay; Rai, Amit; Shah, Pujan; Moore, Arden L.

    2017-06-01

    Diabetic individuals need simple, accurate, and cost effective means by which to independently assess their glucose levels in a non-invasive way. In this work, a sensor based on randomly oriented CuO nanowire networks supported by a polyethylene terephthalate thin film is evaluated as a flexible, transparent, non-enzymatic glucose sensing system analogous to those envisioned for future wearable diagnostic devices. The amperometric sensing characteristics of this type of device architecture are evaluated both before and after bending, with the system’s glucose response, sensitivity, lower limit of detection, and effect of applied bias being experimentally determined. The obtained data shows that the sensor is capable of measuring changes in glucose levels within a physiologically relevant range (0-12 mM glucose) and at lower limits of detection (0.05 mM glucose at +0.6 V bias) consistent with patient tears and saliva. Unlike existing studies utilizing a conductive backing layer or macroscopic electrode setup, this sensor demonstrates a percolation network-like trend of current versus glucose concentration. In this implementation, controlling the architectural details of the CuO nanowire network could conceivably allow the sensor’s sensitivity and optimal sensing range to be tuned. Overall, this work shows that integrating CuO nanowires into a sensor architecture compatible with transparent, flexible electronics is a promising avenue to realizing next generation wearable non-enzymatic glucose diagnostic devices.

  3. Two dimensional PMMA nanofluidic device fabricated by hot embossing and oxygen plasma assisted thermal bonding methods

    NASA Astrophysics Data System (ADS)

    Yin, Zhifu; Sun, Lei; Zou, Helin; Cheng, E.

    2015-05-01

    A method for obtaining a low-cost and high-replication precision two-dimensional (2D) nanofluidic device with a polymethyl methacrylate (PMMA) sheet is proposed. To improve the replication precision of the 2D PMMA nanochannels during the hot embossing process, the deformation of the PMMA sheet was analyzed by a numerical simulation method. The constants of the generalized Maxwell model used in the numerical simulation were calculated by experimental compressive creep curves based on previously established fitting formula. With optimized process parameters, 176 nm-wide and 180 nm-deep nanochannels were successfully replicated into the PMMA sheet with a replication precision of 98.2%. To thermal bond the 2D PMMA nanochannels with high bonding strength and low dimensional loss, the parameters of the oxygen plasma treatment and thermal bonding process were optimized. In order to measure the dimensional loss of 2D nanochannels after thermal bonding, a dimension loss evaluating method based on the nanoindentation experiments was proposed. According to the dimension loss evaluating method, the total dimensional loss of 2D nanochannels was 6 nm and 21 nm in width and depth, respectively. The tensile bonding strength of the 2D PMMA nanofluidic device was 0.57 MPa. The fluorescence images demonstrate that there was no blocking or leakage over the entire microchannels and nanochannels.

  4. A Regression-Based Family of Measures for Full-Reference Image Quality Assessment

    NASA Astrophysics Data System (ADS)

    Oszust, Mariusz

    2016-12-01

    The advances in the development of imaging devices resulted in the need of an automatic quality evaluation of displayed visual content in a way that is consistent with human visual perception. In this paper, an approach to full-reference image quality assessment (IQA) is proposed, in which several IQA measures, representing different approaches to modelling human visual perception, are efficiently combined in order to produce objective quality evaluation of examined images, which is highly correlated with evaluation provided by human subjects. In the paper, an optimisation problem of selection of several IQA measures for creating a regression-based IQA hybrid measure, or a multimeasure, is defined and solved using a genetic algorithm. Experimental evaluation on four largest IQA benchmarks reveals that the multimeasures obtained using the proposed approach outperform state-of-the-art full-reference IQA techniques, including other recently developed fusion approaches.

  5. 76 FR 6927 - Radio Experimentation and Market Trials Under Part 5 of the Commission's Rules and Streamlining...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-08

    ...In this document, the Commission seeks to promote innovation and efficiency in spectrum use in the Experimental Radio Service (ERS). For many years, the ERS has provided fertile ground for testing innovative ideas that have led to new services and new devices for all sectors of the economy. The Commission proposes to leverage the power of experimental radio licensing to accelerate the rate at which these ideas transform from prototypes to consumer devices and services. Its goal is to inspire researchers to dream, discover and deliver the innovations that push the boundaries of the broadband ecosystem. The resulting advancements in devices and services available to the American public and greater spectrum efficiency over the long term will promote economic growth, global competitiveness, and a better way of life for all Americans.

  6. Study and characterization of a MEMS micromirror device

    NASA Astrophysics Data System (ADS)

    Furlong, Cosme; Pryputniewicz, Ryszard J.

    2004-08-01

    In this paper, advances in our study and characterization of a MEMS micromirror device are presented. The micromirror device, of 510 mm characteristic length, operates in a dynamic mode with a maximum displacement on the order of 10 mm along its principal optical axis and oscillation frequencies of up to 1.3 kHz. Developments are carried on by analytical, computational, and experimental methods. Analytical and computational nonlinear geometrical models are developed in order to determine the optimal loading-displacement operational characteristics of the micromirror. Due to the operational mode of the micromirror, the experimental characterization of its loading-displacement transfer function requires utilization of advanced optical metrology methods. Optoelectronic holography (OEH) methodologies based on multiple wavelengths that we are developing to perform such characterization are described. It is shown that the analytical, computational, and experimental approach is effective in our developments.

  7. Cadmium telluride leaching behavior: Discussion of Zeng et al. (2015).

    PubMed

    Sinha, Parikhit

    2015-11-01

    Zeng et al. (2015) evaluate the leaching behavior and surface chemistry of II-VI semiconductor materials, CdTe and CdSe, in response to pH and O2. Under agitation in acidic and aerobic conditions, the authors found approximately 3.6%-6.4% (w/w) solubility of Cd content in CdTe in the Toxicity Characteristic Leaching Procedure (TCLP), Waste Extraction Test (WET), and dissolution test, with lower solubility (0.56-0.58%) under agitation in acidic and anoxic conditions. This range is comparable with prior long-term transformation and dissolution testing and bio-elution testing of CdTe (2.3%-4.1% w/w solubility of Cd content in CdTe). The implications for potential leaching behavior of CdTe-containing devices require further data. Since CdTe PV modules contain approximately 0.05% Cd content by mass, the starting Cd content in the evaluation of CdTe-containing devices would be lower by three orders of magnitude than the starting Cd content in the authors' study, and leaching potential would be further limited by the monolithic glass-adhesive laminate-glass structure of the device that encapsulates the semiconductor material. Experimental evaluation of leaching potential of CdTe PV modules crushed by landfill compactor has been conducted, with results of TCLP and WET tests on the crushed material below regulatory limits for Cd. CdTe PV recycling technology has been in commercial operation since 2005 with high yields for semiconductor (95%) and glass (90%) recovery. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. FDA Benchmark Medical Device Flow Models for CFD Validation.

    PubMed

    Malinauskas, Richard A; Hariharan, Prasanna; Day, Steven W; Herbertson, Luke H; Buesen, Martin; Steinseifer, Ulrich; Aycock, Kenneth I; Good, Bryan C; Deutsch, Steven; Manning, Keefe B; Craven, Brent A

    Computational fluid dynamics (CFD) is increasingly being used to develop blood-contacting medical devices. However, the lack of standardized methods for validating CFD simulations and blood damage predictions limits its use in the safety evaluation of devices. Through a U.S. Food and Drug Administration (FDA) initiative, two benchmark models of typical device flow geometries (nozzle and centrifugal blood pump) were tested in multiple laboratories to provide experimental velocities, pressures, and hemolysis data to support CFD validation. In addition, computational simulations were performed by more than 20 independent groups to assess current CFD techniques. The primary goal of this article is to summarize the FDA initiative and to report recent findings from the benchmark blood pump model study. Discrepancies between CFD predicted velocities and those measured using particle image velocimetry most often occurred in regions of flow separation (e.g., downstream of the nozzle throat, and in the pump exit diffuser). For the six pump test conditions, 57% of the CFD predictions of pressure head were within one standard deviation of the mean measured values. Notably, only 37% of all CFD submissions contained hemolysis predictions. This project aided in the development of an FDA Guidance Document on factors to consider when reporting computational studies in medical device regulatory submissions. There is an accompanying podcast available for this article. Please visit the journal's Web site (www.asaiojournal.com) to listen.

  9. Time interval measurement device based on surface acoustic wave filter excitation, providing 1 ps precision and stability.

    PubMed

    Panek, Petr; Prochazka, Ivan

    2007-09-01

    This article deals with the time interval measurement device, which is based on a surface acoustic wave (SAW) filter as a time interpolator. The operating principle is based on the fact that a transversal SAW filter excited by a short pulse can generate a finite signal with highly suppressed spectra outside a narrow frequency band. If the responses to two excitations are sampled at clock ticks, they can be precisely reconstructed from a finite number of samples and then compared so as to determine the time interval between the two excitations. We have designed and constructed a two-channel time interval measurement device which allows independent timing of two events and evaluation of the time interval between them. The device has been constructed using commercially available components. The experimental results proved the concept. We have assessed the single-shot time interval measurement precision of 1.3 ps rms that corresponds to the time of arrival precision of 0.9 ps rms in each channel. The temperature drift of the measured time interval on temperature is lower than 0.5 ps/K, and the long term stability is better than +/-0.2 ps/h. These are to our knowledge the best values reported for the time interval measurement device. The results are in good agreement with the error budget based on the theoretical analysis.

  10. Design and testing of a novel audio transducer to train string musical instruments

    NASA Astrophysics Data System (ADS)

    Cinquemani, Simone; Giberti, Hermes

    2018-03-01

    Stringed wooden instruments, like violins or double basses, experience a decrease in performance if they are not played for a long time. For this reason, top class instruments are usually given to musicians and played every day to preserve sound quality. The paper deals with the design, construction and testing of a device to be inserted in the bridge of a stringed wooden instrument to simulate the stresses experienced by the instrument during normal playing. The device could provide a simple, fast and inexpensive way to recover the sound of an instrument that has not been played for a period of time, or even to enhance the instrument's sound. The device is based on two magnetostrictive actuators that can exert suitable forces on the body of the violin. The device has been designed and tested to exert forces as constant as possible in the range of frequency between 10 Hz and 15kHz. Experimental tests are carried out to evaluate the effect of the device on the sound produced by the violin during a 3 weeks hours training. Two hi-quality microphones have been used to measure principal harmonics and changes during the test. Results show that in the first part of the test (approximately 100 hours) amplitudes of main harmonics widely change, while in the following their values remain constant. This behavior demonstrates the violin has reached its "nominal" status.

  11. 78 FR 33447 - Draft Applications for Sealed Source and Device Evaluation and Registration

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-04

    ... NUCLEAR REGULATORY COMMISSION [NRC-2013-0104] Draft Applications for Sealed Source and Device... for sealed source and device evaluation and registration. The NRC is requesting public comment on... for Sealed Source and Device Evaluation and Registration.'' The document has been updated from the...

  12. 78 FR 27441 - NIJ Evaluation of Hand-Held Cell Phone Detector Devices

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-10

    ... Hand-Held Cell Phone Detector Devices AGENCY: National Institute of Justice, Department of Justice...-held cell phone detector devices for participation in an evaluation by the NIJ Corrections Technology...-held cell phone detector devices for participation in an evaluation by the NIJ Corrections Technology...

  13. Multifunctional semiconductor micro-Hall devices for magnetic, electric, and photo-detection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gilbertson, A. M.; Cohen, L. F.; Sadeghi, Hatef

    2015-12-07

    We report the real-space voltage response of InSb/AlInSb micro-Hall devices to local photo-excitation, electric, and magnetic fields at room temperature using scanning probe microscopy. We show that the ultrafast generation of localised photocarriers results in conductance perturbations analogous to those produced by local electric fields. Experimental results are in good agreement with tight-binding transport calculations in the diffusive regime. The magnetic, photo, and charge sensitivity of a 2 μm wide probe are evaluated at a 10 μA bias current in the Johnson noise limit (valid at measurement frequencies > 10 kHz) to be, respectively, 500 nT/√Hz; 20 pW/√Hz (λ = 635 nm) comparable to commercial photoconductive detectors;more » and 0.05 e/√Hz comparable to that of single electron transistors. These results demonstrate the remarkably versatile sensing attributes of simple semiconductor micro-Hall devices that can be applied to a host of imaging and sensing applications.« less

  14. 405 nm diode laser, halogen lamp and LED device comparison in dental composites cure: an "in vitro" experimental trial.

    PubMed

    Fornaini, C; Lagori, G; Merigo, E; Rocca, J-P; Chiusano, M; Cucinotta, A

    2015-12-30

    A 405 nm diode laser is indicated for composite materials polymerizing, thanks to the recent evolution in their compositions, absorbing in blue part of the spectrum. The purpose of this research was to evaluate its performance on two different kinds of composite resins. Two different composites were polymerized with a traditional halogen lamp, a LED device and a 405 nm diode laser. The depth of the cure, the volumetric shrinkage, and the degree of the conversion (DC%) of the double bond during the curing process were measured. One-way ANOVA test, Kruskal-Wallis tests, and Dunn comparison tests were used for statistic analysis. Regarding the depth of polymerization, the laser had the worst performance on one composite while on the other, no significant difference with the other devices was observed. The volumetric shrinkage showed that laser produced the lowest change in both of the composites. The DC% measure confirmed these findings. Based on the results of this preliminary study, it is not possible to recommend the 405 nm diode laser for the polymerization of dental composites.

  15. Experimental application of pulsed laser-induced water jet for endoscopic submucosal dissection: mechanical investigation and preliminary experiment in swine.

    PubMed

    Sato, Chiaki; Nakano, Toru; Nakagawa, Atsuhiro; Yamada, Masato; Yamamoto, Hiroaki; Kamei, Takashi; Miyata, Go; Sato, Akira; Fujishima, Fumiyoshi; Nakai, Masaaki; Niinomi, Mitsuo; Takayama, Kazuyoshi; Tominaga, Teiji; Satomi, Susumu

    2013-05-01

    A current drawback of endoscopic submucosal dissection (ESD) for early-stage gastrointestinal tumors is the lack of instruments that can safely assist with this procedure. We have developed a pulsed jet device that can be incorporated into a gastrointestinal endoscope. Here, we investigated the mechanical profile of the pulsed jet device and demonstrated the usefulness of this instrument in esophageal ESD in swine. The device comprises a 5-Fr catheter, a 14-mm long stainless steel tube for generating the pulsed water jet, a nozzle and an optical quartz fiber. The pulsed water jet was generated at pulse rates of 3 Hz by irradiating the physiological saline (4°C) within the stainless steel tube with an holmium-doped yttrium-aluminum-garnet (Ho:YAG) laser at 1.1 J/pulse. Mechanical characteristics were evaluated using a force meter. The device was used only for the part of submucosal dissection in the swine ESD model. Tissues removed using the pulsed jet device and a conventional electrocautery device, and the esophagus, were histologically examined to assess thermal damage. The peak impact force was observed at a stand-off distance of 40 mm (1.1 J/pulse). ESD using the pulsed jet device was successful, as the tissue specimens showed precise dissection of the submucosal layer. The extent of thermal injury was significantly lower in the dissected bed using the pulsed jet device. The results showed that the present endoscopic pulsed jet system is a useful alternative for a safe ESD with minimum tissue injury. © 2012 The Authors. Digestive Endoscopy © 2012 Japan Gastroenterological Endoscopy Society.

  16. Efficacy of New Low-Cost Filtration Device for Recovering Schistosoma haematobium Eggs from Urine

    PubMed Central

    Gyorkos, Theresa W.; Ramsan, Mahdi; Foum, Ali; Khamis, Iddi Simba

    2001-01-01

    A new, inexpensive filtration device for the diagnosis of urinary schistosomiasis was tested against the commonly used Millipore device. The experimental protocol was performed with 25 urine samples known to be positive for Schistosoma haematobium. The results suggest that the new device is as effective as the Millipore device for the diagnosis of urinary schistosomiasis. Its low cost will be attractive to schistosomiasis control programs. PMID:11427595

  17. The practical operational-amplifier gyrator circuit for inductorless filter synthesis

    NASA Technical Reports Server (NTRS)

    Sutherland, W. C.

    1976-01-01

    A literature is reported for gyrator circuits utilizing operational amplifiers as the active device. A gyrator is a two port nonreciprocal device with the property that the input impedance is proportional to the reciprocal of the load impedance. Following an experimental study, the gyrator circuit with optimum properties was selected for additional testing. A theoretical analysis was performed and compared to the experimental results for excellent agreement.

  18. Dusty Plasma Experimental (DPEx) device for complex plasma experiments with flow

    NASA Astrophysics Data System (ADS)

    Jaiswal, S.; Bandyopadhyay, P.; Sen, A.

    2015-11-01

    A versatile table-top dusty plasma experimental device to study flow induced excitations of linear and nonlinear waves/structures in a complex plasma is presented. In this Π-shaped apparatus, a DC glow discharge plasma is produced between a disc shaped anode and a grounded long cathode tray by applying a high voltage DC in the background of a neutral gas (argon) and subsequently a dusty plasma is created by introducing micron sized dust particles that get charged and levitated in the sheath region. A flow of the dust particles is induced in a controlled manner by adjusting the pumping speed and the gas flow rate into the device. A full characterisation of the plasma, using Langmuir and emissive probe data, and that of the dusty plasma using particle tracking data with the help of an idl based (super) Particle Identification and Tracking (sPIT) code is reported. Experimental results on the variation of the dust flow velocity as a function of the neutral pressure and the gas flow rate are given. The neutral drag force acting on the particles and the Epstein coefficient are estimated from the initial acceleration of the particles. The potential experimental capabilities of the device for conducting fundamental studies of flow induced instabilities are discussed.

  19. Design and Characterization of a Soft Robotic Therapeutic Glove for Rheumatoid Arthritis.

    PubMed

    Chua, Matthew Chin Heng; Lim, Jeong Hoon; Yeow, Raye Chen Hua

    2017-07-27

    The modeling and experimentation of a pneumatic actuation system for the development of a soft robotic therapeutic glove is proposed in this article for the prevention of finger deformities in rheumatoid arthritis (RA) patients. The Rehabilitative Arthritis Glove (RA-Glove) is a soft robotic glove fitted with two internal inflatable actuators for lateral compression and massage of the fingers and their joints. Two mechanical models to predict the indentation and bending characteristics of the inflatable actuators based on their geometrical parameters will be presented and validated with experimental results. Experimental validation shows that the model was within a standard deviation of the experimental mean for input pressure range of 0 to 2 bars. Evaluation of the RA-Glove was also performed on six healthy human subjects. The stress distribution along the fingers of the subjects using the RA-Glove was also shown to be even and specific to the finger sizes. This article demonstrates the modeling of soft pneumatic actuators and highlights the potential of the RA-Glove as a therapeutic device for the prevention of arthritic deformities of the fingers.

  20. A microfluidic-based lid device for conventional cell culture dishes to automatically control oxygen level.

    PubMed

    Lee, Seung Yeob; Yang, Sung

    2018-04-25

    Most conventional hypoxic cell culture systems undergo reoxygenation during experimental manipulations, resulting in undesirable effects including the reduction of cell viability. A lid device was developed herein for conventional cell culture dishes to resolve this limitation. The integration of multilayered microfluidic channels inside a thin membrane was designed to prevent the reoxygenation caused by reagent infusion and automatically control the oxygen level. The experimental data clearly show the reducibility of the dissolved oxygen in the infusing reagent and the controllability of the oxygen level inside the dish. The feasibility of the device for hypoxia studies was confirmed by HIF-1α experiments. Therefore, the device could be used as a compact and convenient hypoxic cell culture system to prevent reoxygenation-related issues.

Top